PORTMAN ELECTRONICS CTS-100XT Heavy Equipment Unit/Container Tracking User Manual

PORTMAN ELECTRONICS (DONGGUAN) CO., LTD. Heavy Equipment Unit/Container Tracking

Users manual

Download: PORTMAN ELECTRONICS CTS-100XT Heavy Equipment Unit/Container Tracking User Manual
Mirror Download [FCC.gov]PORTMAN ELECTRONICS CTS-100XT Heavy Equipment Unit/Container Tracking User Manual
Document ID1038984
Application IDMcWcDPGAvcbya4nwk4Isww==
Document DescriptionUsers manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize96.24kB (1203047 bits)
Date Submitted2008-12-03 00:00:00
Date Available2008-12-03 00:00:00
Creation Date2008-11-18 15:47:13
Producing SoftwareAcrobat Distiller 7.0 (Windows)
Document Lastmod2008-11-18 15:47:13
Document Titleuntitled

GPS&GPRS CONTAINER TRACKING SYSTEM
MODEL: CTS-100 SERIES
OPERATION / INSTALLATION MANUAL
I. BRIEF INTRODUCTION
Container Tracking System utilizes the GPS and GPRS functions in one unit. You can monitor the container or
the vehicle location and set the system remotely. In addition, the unit will send event report if any trigger
occurs.
The standard report sent by the unit includes the information: (1) unit’s ID, (2) status, (3) time, (4) GPS’s
latitude and longitude, (5) speed, (6) direction, (7) device’s status, (8) event number, and (9) report
configuration parameters.
The reporting mode can be categorized as ‘normal’ mode, and ‘power saving’ mode. In normal mode, the GPS
will always be activated while moving, and it can be shut off the GPS when stop (for power saving purpose). To
enable the maximum power saving, user can choose “power saving mode”. In this mode, the GPS will be
activated only when there is a report to send while moving. The report parameters can be set from the PC setup
program. CTS-100 can be set to go in sleep mode (while not moving); the system will cut the power of GPS
module in order to save power. With build-in 3-D acceleration sensor, CTS-100 can select related reporting
modes with respect to it is moving or not.
The device has built-in 4 Geo-fences; it will send the report to the server if the Geo-fence event is triggered.
The UNIT must be initialized by PC setup program in order to make communication with the remote server
/call center. There are four main sections that allow users to program the device, (1) User detail (Device ID,
server IP, and port, GPRS APN….) (2) Geo-fence (4 circular Geo-fence) (3) Report (Time, Distance, speed,
Low battery, wakeup …) (4)Trigger report(Tamper ,Door)
When there is no GPRS service or the server close. The unit will send short message to the preset number. The
max number of SMS message (monthly usage) and the monthly renew date can be set from the pc setup
program or the remote setup program. Only 1 SMS number can be set. The reports sent via the SMS will be out
again via GPRS after a valid GPRS connection is made.
CTS-100 can be configured by the PC setup program or the Over-the-Air (OTA) commands / or remote
program. The unit can communicate with the server via UDP or TCP protocol. The protocol can be selected
from the PC-setup program or remote server commands.
Flash memory for recording reports up to 900 reports. It can be read out from the PC setup program via serial
port.
Using built-in real time clock to identify the report time, when GPS signal is lost. Hence, if the report is
received with “LAST KNOWN” message, the time in the report will be the real time clock, but the GPS
position will be the last known valid GPS position.
Three LED indicate the status of the system:
Power indicator: When the unit power on, the led will flash 1time/3sec by green. If the power has low status,
the LED will change to red. when the battery charge ok then power LED will change to green. If tamper switch
is triggered, the power indicator will flash twice continuously; if door sensor is triggered, the power indicator
will flash 5 times continuously
GPS indicator: LED is GREEN when the unit has acquired a valid GPS signal, and it will flash when the unit is
searching GPS signal.
GSM/GPRS indicator: Orange LED will flash when the device is connected to the server with valid GPRS
connection. It will stay continuously on when it is in GSM mode. It will stay off if there is no GSM reception.
Note that the GSM/GPRS and GPS LED’s indication will not be valid until the system goes to the working
mode, normally 30 seconds after power on.
II. The main unit’s housing with Strong Magnetic Gives You Easy Instant Install Placement!
Just like we put you in control on how and when your CTS-100 reports to you with your own online controls,
we also put YOU in control of how you want your CTS-100 installed on any container or vehicle.
In addition, the unit has built-in door magnetic sensor, it used to detect the container door status.
III. BASIC FUNCTIONS
FUNCTIONS
APPLICATIONS
GPS
GPS receiver will output a complete position, velocity, and time (PVT) solution in the
NMEA Version 3.0 protocol.
GPRS, SMS
GPRS use standard TCP or UDP communicate protocol. If the GPRS service is failed,
the SMS mode will be turned on for emergency use.
Button
Power switch
PC-setup
Initialize the unit and program the device, including Network APN, server IP address,
user message, report control, and Geo-fence setting, etc …
Note that Network APN and server IP details must be set before the installation.
Standard Report
Automatic report for tracking purpose:
Fixed time report
Fixed distance report
Trigger report
History data store
900 report can be saved in unit and read from server and pc-setup
IV. PANEL INSTALLATION
SIM card inserting guide:
4
5
CTS-100 Installation guide (Project one: vehicle doors with gasket)
CTS-100 Installation guide (Project two: vehicle doors without gasket)
V. PC SETUP AND SYSTEM INITIATION
PC setup Procedure:
1.) Connect the standard RS232 cable to the DB9 port.
2.) Open the PC setup program.
3.) Select the correct COM port for communication.
4.) Click “OK” to start the program
5.) Power on the device.
Note that, if the connection fails, please check the cable connection is secured correctly.
Note: Turnover SIM card lid angle as following drawing.
A. LOGIN dialog window
Connect UNIT DB9 port to the PC serial port with a standard serial cable. Select the COM port, and click
“OK”.
Note that: it is necessary to power on the device soon after starting the PC setup program.
PC setup program will detect the hardware for 60 seconds. If no hardware is detected, it will exit.
During the opening up screen shown as below, user can press “Esc” key to terminate the program.
B. Version No. Checking
The below interface will last until correct UNIT Version No. is checked. (You should run this program before
turn on power of UNIT)
C. MAIN INTERFACE
1. [User detail]:
If the SIM card is password protected, user can input the “SIM PIN” window to set password of SIM Card.
IMEI: Any operate with ‘request or request all’ after GPRS power on, the module series number will display
automatically, otherwise it displayed with space.
Set UNIT ID and UNIT password of for the device.
Set Access Point Name (APN), User Name, Password. The maximum length of the APN, User name and
Password is 49 characters.
To select communication with GPRS or SMS, when select SMS communication; the GPRS login information
and server information are reverse video.
Set Access Point Name (APN), User Name, Password. The maximum length of the APN, User name and
Password is 49 characters.
TCP/UDP address and Port number of alarm center being set, UNIT will send message to these address.
Note that either TCP or UDP should be selected.
Note: the IP address and port must input correctly, otherwise it will cause fail to make a call.
10
Set the primary SMS Number of the server. The unit will send reports to the server if GPRS connection is
failed.
Setup the max number of the SMS can be sent out from the unit every month. By default, it will be renewed by
the first date of every month.
UNIT can save 900 reports (900-1). Click ‘Export’ button can export them with Excel or Text format.
“Initialize” button: clear all data in UNIT.
Request All: read out the whole existing setting from CTS-100.
Request: read out the setting in the current page.
Apply: transfer the setting to CTS-100 in the current pages.
Apply All: transfer the whole setting to CTS-100.
Load: load the saved configuration files.
Save: save the current configuration setting to a file.
Add to database: Add the current configuration to database
“Exit” button: exit PC-Setup to main program.
11
2. [Geo-fence]:
Setup the circular Geo-fence parameters in this window. The format will be center of the Geo-fence and the
related radius.
12
3. [Report]:
Report setup can be configured in this section. To activate the function(s), please select “√” in checkbox and fill
in data in the textbox. There are 2 modes for the CTS-100, first is the Normal mode, and second is the Power
saving mode. In normal mode, the GPS will be always activated if CTS-100 is in moving state. However, if in
Power saving mode, CTS-100 will turn off the GPS power if there is no report to send.
Note: that user can configure the wakeup report if the device is in “stop” (not moving) state.
Normal mode, report will be summarized as:
(1) Fixed time report
Parameters: On/Off, and time.
(2) Fixed distance report
Parameters: On/Off, and distance. (min. distance is 0.1 km, max. distance is 100 km).
(3) Speeding report: (min. speed is 0.1 km/Hr, max. speed is 1000 km/Hr).
Parameters: on/off, and speed
13
(4) GPS wakeup report:
While the device is in stop status, user can let the GPS go to sleep mode for power saving. If select GPS sleep
ON, user can setup the wakeup report configuration/ or NO GPS wakeup report.
IF select GPS SLEEP OFF, CTS-100 will follow the report sending rule in “When Moving” section.
Power saving mode
While in Power saving mode, CTS-100 will cut off the GPS power if there is no report to send.
Report configuration will be listed as: the fixed time report while moving, and wakeup report / or no GPS
wakeup report while stop. In this mode, in order to save power unit will cut power of GPS, only wake up GPS
at the time of send report.
GPRS dial-up procedure
1) GPRS always one-line
Parameters: Reconnect interval
While using this mode, when the unit can not searched GPRS signal, system will reconnect GPRS interval a
preset value. (e.g.: 1minute)
14
2) Base on report mode
Parameters: Max. reconnect times, reconnect interval
While using this mode, the unit will connect to the server when there is a report to send. If the first connection
is failed, it will retry to connect to the server up to the max. reconnect times. Each retry will be separated by the
reconnect “interval”.
3) GPRS connect once
While using this mode, the unit will connect to the server when there is a report to send (but only try once). If it
is not successful, the report will be stored and sent out in the next successful connection. Disconnect GPRS
connection when report sending is completed.
4) Reduce GPRS dialup method
Parameters: On/Off, Max. reconnect times, connect delay
If this method is used, the unit will reduce the GPRS dial-up connection when the dial-up is failed after number
of times. User can define the delay time for the unit before try to reconnect to the server. If there is trigger
report, the unit will connect to server immediately.
Keep alive procedure
Parameters: On/Off, and interval / retry times. In order to keep connection in GPRS network, the unit can be set
to send short keep alive report to the server in order to prevent the disconnection from the mobile service
provider.
Send reports after a successful keep alive ACK. Parameters: On/Off .
If you select this function, all the reports will only be sent out after a successful keep alive ACK. (So if your
keep alive time is shorter then select this function will be OK.) This function is very useful while using UDP to
prevent report lost.
Send a keep alive packet right before a due reports if no data stream within certain time: Parameters: On/Off,
and idle time.
Some GSM provider might cut connection, if there is no data within certain time. It might result report lost in
this “fake connection” duration. For example, you can set parameters in this region, ex 20 mins. (it means if the
unit did not send any data in this 20 mins (including keep alive or normal reports) ), then it will send a keep
alive packet to check if the GPRS connection is valid or not. If not, it will actively reconnect to GPRS network.
Special command for SMS mode:
If the CTS-100 is not in the GPRS online status, user can send command &&Y02 or &&Y04 to ask unit to
connect to server. This command can be sent from any device via SMS;
&&Y02:
When received this command, system will actively try to connect to server in next 600 seconds.
15
&&Y04,[connection time],[report interval]:
For example: &&Y04,3600,60
When received this command, system will connect to server in the next 3600 seconds, and send one report
out every 60 seconds.
Low battery report:
Low battery warning report (to alert user when the external battery level is low)
Parameters: On/Off, and warning battery level for report. For example, 30 to represent 30% lower level report.
The system will ignore the parameter with a value ‘0’ to prevent continuous non-stop reporting. Low battery,
unit will cut power of GPS, only call function will be activated.
Acceleration sensor:
To determine whether CTS-100 is moving or not, user can select the sensitivity of the “acceleration sensor”. It
is distinguished by the tilt angle of the device. If the unit tilted more than the degree set here, CTS-100 will be
in moving mode. Otherwise, it will be in stop mode. The smaller the parameter of degree for the sensor set in
pc-setup is, the higher the sensitivity is. Otherwise, the result is the opposite.
You can select the Acceleration sensor trigger report to be sent or not, while the unit is moved. “Select” (by
click), the related reports will be sent. Otherwise the report will be ignored, when the device is moved.
16
4. [Trigger report setup]
The unit has built-in door magnetic sensor and tamper switch, user can select if send report when the door
sensor and tamper switch has triggered.
1.door sensor :It will send out event reports when door on or off.
2.Tamper switch: the tamper switch is used to check the box of host, when the box of host is moved over, it will
send out a relevant report.
CTS-100 SPECIFICATIONS
Physical Parameters
Enclosure dimensions (mm)
96(L)*50(W)*42(H)
Unit Weight
About 400g
Electrical
Operating current
52mA
Voltage (Recharge)
5V-16V
Current (Recharge)
770mA
Current (sleep)
0.5-11.6mA
Battery
Battery
Battery type
Battery capacity Charge type
Lithium 3.7V
3600mAh
Built-in charge circuit
17
GPS*
Channels
Frequency
Sensitivity
Tracking
Acquisition (Cold start)
Position accuracy (Horizontal)
20 parallel tracking
L1-1575 MHz
-159 dBm
-142 dBm
<2.5m CEP autonomous
<2.0m CEP SBAX
Time to first fix
Hot start 1
<1s
Warm start 2
<32s
Cold 3
<35s
Standard GPS software
NMEA message switchable
GGA, GSA GSV, VTG, RMC, GLL
GPRS*
Frequency Range (MHz)
(Be used in CTS-100MT/ CTS-100FT/CTS-100ST)
Frequency Range (MHz)
GPRS* (Be used in CTS-100XT)
GPRS connectivity
(Be used in CTS-100MT/ CTS-100FT/CTS-100XT/CTS-100ST)
SIM card interface
(Be used in CTS-100ST)
SIM card interface
(Be used in CTS-100MT/ CTS-100FT/CTS-100XT)
Antenna Impedance
(Be used in CTS-100MT/ CTS-100FT/CTS-100XT/CTS-100ST)
IO Connection
POWER SWITCH
Communication
GPRS \SMS\RS232\USB
Environmental
Operating Temperature
Storage Temperature
-20°C to +55°C
-40°C to +85°C
Accessories
1. Internal battery
2. Magnetic sensor
3. PC setup cable
18
850/900/1800/1900
900&1800&1900 or 850&1800&1900
GPRS multi-slot class 10
GPRS mobile station class B
1.8V/3.0V
3V
50ohms
FCC FOR CTS-100XT
15.21
Federal Communications Commission (FCC) Statement
You are cautioned that changes or modifications not expressly approved by the part responsible for compliance
could void the user’s authority to operate the equipment.
15.105(b)
Federal Communications Commission (FCC) Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to
part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
Operation is subject to the following two conditions:
1) this device may not cause interference and
2) this device must accept any interference, including interference that may cause undesired operation of the
device.
FCC RF Radiation Exposure Statement:
1.This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
2.This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment.
This equipment should be installed and operated with a minimum distance of 20 centimeters between the
radiator and your body.
19

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
XMP Toolkit                     : 3.1-701
Producer                        : Acrobat Distiller 7.0 (Windows)
Modify Date                     : 2008:11:18 15:47:13+08:00
Create Date                     : 2008:11:18 15:47:13+08:00
Format                          : application/pdf
Title                           : untitled
Document ID                     : uuid:14992530-6ee4-4d31-bcaf-870fb5d40b6a
Instance ID                     : uuid:3df9138b-9378-4071-8564-e275b3c1b3e2
Page Count                      : 20
EXIF Metadata provided by EXIF.tools
FCC ID Filing: TBQCTS-100XT

Navigation menu