PaloSanto Solutions MICROUCS Elastix microUCS User Manual microUCS Installastion Guide
PaloSanto Solutions Elastix microUCS microUCS Installastion Guide
Manual
microUCS User Manual Hardware Version:V1.2 Guide Version: V1.0 Copyright Copyright© 2012 PaloSanto Solutions Inc. All rights reserved. No part of this document may be reproduced without prior written permission. Confidentiality Information contained herein is of a highly sensitive nature and is confidential and proprietary to PaloSanto Solutions Inc. No part may be distributed, reproduced or disclosed orally or in written form to any party other than the direct recipients without the express written consent of PaloSanto Solutions Inc. Disclaimer PaloSanto Solutions Inc. reserves the right to modify the design, characteristics, and products at any time without notification or obligation and shall not be held liable for any error or damage of any kind resulting from the use of this document. PaloSanto Solutions has made every effort to ensure that the information contained in this document is accurate and complete; however, the contents of this document are subject to revision without notice. Please contact PaloSanto Solutions to ensure you have the latest version of this document. Trademarks All other trademarks mentioned in this document are the property of their respective owners. Compliance information EMI and EMS For FCC, MICROUCS has been tested as a CPU board, installed in an enclosure, with the top cover removed. No further testing should be required if the board is used with other FCC tested modular components. Please see http://www.fcc.gov/oet/ for more details. Testing for CE mark must be done at the level of the complete product. Please contact PaloSanto Solutions for assistance and documentation. It can be used as an I.T.E, as well as a generic device. For an I.T.E, it must be tested according to EN55022 and EN55024; for a generic device, it is suit for EN 61000-6-2 (EMI test for commercial and light industrial environment) and EN61000-6-3 (Immuty test for Industrial environment). ESD For satisfactory resistance to electrostatic discharge events (ESD), the case of the MICROUCS board should be grounded earth Ground termintal. (eg. through the mounting holes, or the serial port connector). Under this condition, the system can be get class B evaluation according to EN 61000-4-2. Recycling / disposal Do not discard electronic products in household trash! All waste electronics equipment should be recycled according to local regulations. Information for the recycler Please cut off Lithium battery, if present, for separate recycling. PaloSanto Solutions enclosures are made of aluminum. Chapter 1 Overview The microUCS is the ideal IP PBX for small business or for your home, allowing you to monitor your communications in a very small but also powerful device that comes pre-installed with Elastix. A micro computer with a powerful solution, The compact design of microUCS together with Elastix® as a unified communications solution, makes it a powerful IP PBX that allows you to monitor communications in your office or home from anywhere. Easy to install, powerful administration as only Elastix® offers and its very low power consumption, make it a very safe and cost effective solution. Features Auto Attendants Voicemail Dial-By-Name Directory Music on Hold Multiple Languages Ring Groups Call Queue Call Waiting Caller Display Conference Call Call Hold/Transfer Call Park Call Pickup Automatic Fax Detection Remote Management Remote Extensions Specification CPU: TI AM1808B 456MHZ DRAM: 2 GB DDR2 SDRAM Storage: 1 SD Socket I/O: 1*DB9 serial port, 1*USB 2.0 port Network interface: 10/100Mbps Operating System: Elastix 32 bitx PBX size: (28.3mm x 165 mm x95.8mm) Temperature: 0°C to 60°C PCB layer: 6 Voltage range :12V DC supply through DC jack Power dissipation: ~1.5W (Minimum Power Dissipation) Chapter 2 microUCS Connector and Jumper 1. Layout 2. Connector and Jumper List Name Function J1 J12 J13 J2 J4 Main Power in Jacket Serial Port (RS232) Ethernet Port USB Port SD Card interface 3. System Status Indicator Name Function D3 System status indicator 4. Connector and Jumper Description J1 Main Power Jacket DC in @12V J13 Pin Name Gnd Vin 100Mbps Ethernet Port Pin Name TD+ TDRD+ RD- J2 USB Port 1 USB2.0 ports. 500 mA Continuous Current per Channel. Short-Circuit and Thermal Protection with Overcurrent Logic. J12 Pin Name Pin Name 5v Data- Data+ Ground Serial Port (rs232) Pin Name -- RXD TXD -- GND -- -- -- -- FCC STATEMENT: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Warning: Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: Reorient or relocate the receiving antenna. Increase the separation between the equipment and receiver. Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. Consult the dealer or an experienced radio/TV technician for help.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Producer : GPL Ghostscript 9.02 Keywords : Modify Date : 2013:07:26 15:19:22+08:00 Create Date : 2013:07:26 11:40:17+08:00 Creator Tool : PDFCreator Version 1.2.1 Metadata Date : 2013:07:26 15:19:22+08:00 Document ID : 9c4e2984-f800-11e2-0000-b6a2ceaed2be Instance ID : uuid:84875d84-642b-4f69-a014-4465490113c5 Format : application/pdf Title : microUCS_Installastion_Guide Creator : Administrator Description : Description (x-repair) : Page Count : 8 Author : Administrator Subject :EXIF Metadata provided by EXIF.tools