PaloSanto Solutions MICROUCS Elastix microUCS User Manual microUCS Installastion Guide

PaloSanto Solutions Elastix microUCS microUCS Installastion Guide

Manual

Download: PaloSanto Solutions MICROUCS Elastix microUCS User Manual microUCS Installastion Guide
Mirror Download [FCC.gov]PaloSanto Solutions MICROUCS Elastix microUCS User Manual microUCS Installastion Guide
Document ID2028785
Application ID3yOf0Pj1NQPMDRFYxb233g==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize10.41kB (130149 bits)
Date Submitted2013-07-30 00:00:00
Date Available2013-07-30 00:00:00
Creation Date2013-07-26 11:40:17
Producing SoftwareGPL Ghostscript 9.02
Document Lastmod2013-07-26 15:19:22
Document TitlemicroUCS_Installastion_Guide
Document CreatorPDFCreator Version 1.2.1
Document Author: Administrator

microUCS User Manual
Hardware Version:V1.2
Guide Version: V1.0
Copyright
Copyright© 2012 PaloSanto Solutions Inc. All rights reserved. No part of this
document may be reproduced without prior written permission.
Confidentiality
Information contained herein is of a highly sensitive nature and is confidential and
proprietary to PaloSanto Solutions Inc. No part may be distributed, reproduced or
disclosed orally or in written form to any party other than the direct recipients without
the express written consent of PaloSanto Solutions Inc.
Disclaimer
PaloSanto Solutions Inc. reserves the right to modify the design, characteristics, and
products at any time without notification or obligation and shall not be held liable for
any error or damage of any kind resulting from the use of this document.
PaloSanto Solutions has made every effort to ensure that the information contained in
this document is accurate and complete; however, the contents of this document are
subject to revision without notice. Please contact PaloSanto Solutions to ensure you
have the latest version of this document.
Trademarks
All other trademarks mentioned in this document are the property of their respective
owners.
Compliance information
EMI and EMS
For FCC, MICROUCS has been tested as a CPU board, installed in an enclosure,
with the top cover removed. No further testing should be required if the board is used
with other FCC tested modular components. Please see http://www.fcc.gov/oet/ for
more details.
Testing for CE mark must be done at the level of the complete product. Please
contact PaloSanto Solutions for assistance and documentation. It can be used as an
I.T.E, as well as a generic device. For an I.T.E, it must be tested according to
EN55022 and EN55024; for a generic device, it is suit for EN 61000-6-2 (EMI test for
commercial and light industrial environment) and EN61000-6-3 (Immuty test for
Industrial environment).
ESD
For satisfactory resistance to electrostatic discharge events (ESD), the case of the
MICROUCS board should be grounded earth Ground termintal. (eg. through the
mounting holes, or the serial port connector). Under this condition, the system can be
get class B evaluation according to EN 61000-4-2.
Recycling / disposal
Do not discard electronic products in household trash!
All waste electronics equipment should be recycled according to local regulations.
Information for the recycler
Please cut off Lithium battery, if present, for separate recycling.
PaloSanto Solutions enclosures are made of aluminum.
Chapter 1 Overview
The microUCS is the ideal IP PBX for small business or for your home, allowing
you to monitor your communications in a very small but also powerful device that
comes pre-installed with Elastix.
A micro computer with a powerful solution, The compact design of microUCS
together with Elastix® as a unified communications solution, makes it a powerful IP
PBX that allows you to monitor communications in your office or home from
anywhere. Easy to install, powerful administration as only Elastix® offers and its very
low power consumption, make it a very safe and cost effective solution.
Features
Auto Attendants
Voicemail
 Dial-By-Name Directory
 Music on Hold
 Multiple Languages
 Ring Groups
 Call Queue
 Call Waiting
 Caller Display
 Conference Call
 Call Hold/Transfer
 Call Park
 Call Pickup
 Automatic Fax Detection
 Remote Management
 Remote Extensions
Specification
CPU: TI AM1808B 456MHZ
DRAM: 2 GB DDR2 SDRAM
Storage: 1 SD Socket
I/O:
1*DB9 serial port, 1*USB 2.0 port
Network interface: 10/100Mbps
Operating System: Elastix 32 bitx
PBX size: (28.3mm x 165 mm x95.8mm)
Temperature: 0°C to 60°C
PCB layer: 6
Voltage range :12V DC supply through DC jack
Power dissipation:
~1.5W (Minimum Power Dissipation)
Chapter 2 microUCS Connector and Jumper
1. Layout
2. Connector and Jumper List
Name
Function
J1
J12
J13
J2
J4
Main Power in Jacket
Serial Port (RS232)
Ethernet Port
USB Port
SD Card interface
3. System Status Indicator
Name
Function
D3
System status indicator
4. Connector and Jumper Description
J1 Main Power Jacket
DC in @12V
J13
Pin
Name
Gnd
Vin
100Mbps Ethernet
Port
Pin
Name
TD+
TDRD+
RD-
J2 USB Port
1 USB2.0 ports. 500 mA Continuous Current per Channel. Short-Circuit and Thermal
Protection with Overcurrent Logic.
J12
Pin
Name
Pin
Name
5v
Data-
Data+
Ground
Serial Port (rs232)
Pin
Name
--
RXD
TXD
--
GND
--
--
--
--
FCC STATEMENT:
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may
cause undesired operation.
Warning: Changes or modifications not expressly approved by the party responsible
for compliance could void the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a residential
installation.
This equipment generates uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or more of the
following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Producer                        : GPL Ghostscript 9.02
Keywords                        : 
Modify Date                     : 2013:07:26 15:19:22+08:00
Create Date                     : 2013:07:26 11:40:17+08:00
Creator Tool                    : PDFCreator Version 1.2.1
Metadata Date                   : 2013:07:26 15:19:22+08:00
Document ID                     : 9c4e2984-f800-11e2-0000-b6a2ceaed2be
Instance ID                     : uuid:84875d84-642b-4f69-a014-4465490113c5
Format                          : application/pdf
Title                           : microUCS_Installastion_Guide
Creator                         : Administrator
Description                     : 
Description (x-repair)          : 
Page Count                      : 8
Author                          : Administrator
Subject                         : 
EXIF Metadata provided by EXIF.tools
FCC ID Filing: PHP-MICROUCS

Navigation menu