Panasonic Mobile Communications 611849144431A RRH4x40-PCS KS24829L11 User Manual
Panasonic Mobile Communications Co., Ltd. RRH4x40-PCS KS24829L11
User Manual
PCS RRH List11 Installation Guide Issue: 1.0.0 PCS RRH List11 Installation Guide Product Name : RRH4x40-PCS KS24829L11 Model Number : 849144431 Issue: 1.0.0 Date; July 21, 2011 1/17 PMC CONFIDENTIAL PCS RRH List11 Installation Guide Issue: 1.0.0 Revison History Issue No. 1.0.0 Description First edition Date July 08, 2011 2/17 PMC CONFIDENTIAL PCS RRH List11 Installation Guide Issue: 1.0.0 Table of Contents Revison History ..................................................................................................................................... 2 Table of Contents ................................................................................................................................... 3 1 INTRODUCTION ............................................................................................................................. 4 1.1 System Overview ...................................................................................................................... 4 1.2 Equipment Outline .................................................................................................................... 5 1.3 Structural Outline ...................................................................................................................... 6 1.4 Specification ............................................................................................................................. 7 1.4.1 System Specification ..........................................................................................................7 1.4.2 Optical Module Specification ..............................................................................................8 1.4.3 PCS Band Remote Radio Heads Specification ................................................................... 9 2 Installing the RRH ......................................................................................................................... 10 2.1 Appearance ............................................................................................................................ 10 2.2 User Interface ......................................................................................................................... 11 2.3 Cable List ............................................................................................................................... 13 2.4 Power cable installing procedure ............................................................................................ 14 2.5 Powering On the RRH ............................................................................................................ 16 2.6 System Start-Up Procedure .................................................................................................... 16 3 FCC WARING ............................................................................................................................... 17 3/17 PMC CONFIDENTIAL PCS RRH List11 1 IN Installation Guide Issue: 1.0.0 TRODUCTION 1.1 S ystem Overview PCS R RH List11 co nnect w ith BBU w hich made by Alcatel -Lucent. An d, this RR H is transiver system which is support LTE and CDMA fuction in 1900MHz frequency band range. List11 consist from 2pcs of List10 whch is connected by optical cabel. CPRI Interface of one PCS RRH List10 connect to BBU (LTE) Another one CPRI interface connect to BBU (CDMA) CPRI BBU(LTE) PCS RRH TX25MHz List10 BBU(CDMA) PCS RRH TX25MHz List10 PCS RRH List11 Figure 1-1 System Overview 4/17 PMC CONFIDENTIAL PCS RRH List11 Installation Guide Issue: 1.0.0 1.2 Equipment Outline OCI (Ether) DC -48V BBU(LTE) Primary CPRI Secondary PCS RRH TX25MHz List10 Alams AISG CPRI Monitor Tower-top Equipment Secondary BBU(CDMA) Primary CPRI DC -48V PCS RRH TX25MHz List10 Identification connector Alams PCS RRH List11 Figure 1-2 Equipment Outline ① ② ③ ④ ⑤ ⑥ ⑦ Execute transmit and receive BBU and UL/DL Digital Signal by optical interface Enable to maintain RRH with O CI (On site Confi guration Inte rface) an d Pe rsonal Computer. Enable to use Alarm-i nterface detect func tion(one is moni toring. a nother is detection for 2pcs List10) AISG suppl y an d contr ol po wer function w hich is connec ted to towe r-top e quipment from RRH This system support DC -48 Vpower input Execute sever al fun ctions (S tatus-Control/Tranciver-Control/Mesurement/Failure -Control…) based on control message of BBU. Enable to download Software(Control Software, DSP Firmware、FPGA Data) as Remotely. 5/17 PMC CONFIDENTIAL PCS RRH List11 Installation Guide Issue: 1.0.0 1.3 S tructural Outline 【Structure Outline】 ① 1system(List11) consist from 2pcs of RRH(List10) ② Thermal method is naturally air‐cooled engine(Cooling Fan Less) ③ Enable to l oad next ca ble (P ower Cable/Optical C able/AISG Ca ble/ALM Ca ble/AUX Cable) from bottom side of the RRH. And, enable to load Antenna Cable from Upper side of the system ④ Equipped M6 electrical ground in lower side of the system ⑤ In order to monitoring output power of transmi ssion point, Implement 2pcs (List10) of electrical terminal. ⑥ There are installing “Water proof cap” and “Dust Proof Cap” as external connector ⑦ There are LED in bottom side of the RRH which can monitoring system status. ⑧ All function can control by control box which box can be open ⑨ Enable to install “ibolt” to upper side of the system 6/17 PMC CONFIDENTIAL PCS RRH List11 Installation Guide Issue: 1.0.0 1.4 S pecification 1.4.1 S ystem Specification No Item 1 Input Power 2 Powe r Consumption 3W eight Water resistant level 5T emperature range 6 Humi dity range 7 Dime nsion Thermal Type Setting Location Content Remark -48V (-37V~-57V) 340.7W x2 Less than 20kg IP65 as specified by IEC529 IP66 as specified by IEC60529 NEMA type4 -40~+55℃ 5~95% W:330 mm D:176 mm H:530 mm ( not include connectors ) naturally air cooled engine Outside 7/17 PMC CONFIDENTIAL PCS RRH List11 Installation Guide Issue: 1.0.0 1.4.2 Optical Module Specification No Item 2 Bit Condition/etc Optical Center Length Rate Transmission Distance Remark <Primary port> DL:1550 nm、UL:1310 nm <Secondary port> Mix mode:1550 nm/1310 nm RRH1:1550 nm, RRH2:1310 nm or RRHq:1310 nm, RRH2:1550 nm <Primary port> CDMA:0.6144 Gbps~1.2288 Gbps LTE :1.2288 Gbps~6.1440 Gbps <Secondary port> 2.4576 Gbps~6.144 Gbps <Primary port> Maximum 20 km <Secondary port> Maximum 50m 8/17 PMC CONFIDENTIAL PCS RRH List11 Installation Guide Issue: 1.0.0 1.4.3 PCS Band Remote Radio Heads Specification No Item Type Remark 1 Supp ort Technologies RF Output Power LTE/CDMA 40W/Branch×2×2 List11 co nsist fr om 2pcs of List10 Downlink RF Frequency Uplink RF Frequency 5 Numb er of Carrier 1930 MHz –1995 MHz 1850 MHz –1915 MHz LTE :2Carrier×2 CDMA:8Carrier×2 9/17 PMC List11 co nsist fr om 2pcs of List10 CONFIDENTIAL PCS RRH List11 Installation Guide Issue: 1.0.0 Installing the RRH 2.1 Appe arance 4-M8 female threads for Equipment mounting (There are 2-M8 female threads on opposite side) 4-M6 female threads for Ground Lugs (There are 2-M6 female threads on opposite id ) Figure 2-1 Appearance of the RRH with connector covers 10/17 PMC CONFIDENTIAL PCS RRH List11 Installation Guide Issue: 1.0.0 2.2 U ser Interface (2) (1) Figure 2-2 User Interface (Top view) (3) (10) (8) (4) (9) (7) (5) (11) (6) (13) (14) (12) Figure 2-3 User interface (Bottom view) (18) (15) (16) (17) (19) Figure 2-4 Detail of Service Access Ports 11/17 PMC CONFIDENTIAL PCS RRH List11 Installation Guide Issue: 1.0.0 Table 2-1 Connectors, LED, Reset button etc. No. Location Connector Name Connector Type and Comment On the Top TX/RX 1 7/16 DIN F TX/RX 2 7/16 DIN F AUX RX1 N-type F AUX RX2 N-type F CPRI PRI SFP Connector Tyco Electronics 1888247-1 SFP Shield Cage Tyco Electronics 2007198-1 Flange Connector SFP with Waterproof Radial Part# R299.988.00 SFP Connector Tyco Electronics 1888247-1 SFP Shield Cage Tyco Electronics 2007198-1 Flange Connector SFP with Waterproof Radial Part# R299.988.00 On the Bottom CPRI SEC Status LED Indicate green or red or yellow AISG Female 8-pin circular connector, per IEC 60130-9 9 External User Alarms 1-4 Female 8-pin circular connector, per IEC 60130-9 10 DC -48V IN Water-proof entry connector can be mounted 11 V entilator 12 TX MON 1 SMA F 13 TX MON 2 SMA F 14 Service access door 15 Service access Port on the Bo ttom of the 16 OCI RRH 17 Reset Serial Interface 18 Domestic Port 1 19 Sensor for service access door (Ethernet) button IEEE1394 RJ45 12/17 PMC CONFIDENTIAL PCS RRH List11 Installation Guide Issue: 1.0.0 2.3 Cable List 1. Power cable; # 14 AWG strand wires are recommended. From # 14 to # 8 AWG strand wires are available. 13/17 PMC CONFIDENTIAL PCS RRH List11 Installation Guide Issue: 1.0.0 2.4 Power cable installing procedure 1. Preparation of Power cable 1.1. Remove the jacket of power cable by 30 mm. 1.2. Strip the jacket from an inner cable by 8 mm. Figure 2-5 Preparation of Power cable Warning Do not damage the power cable when cutting around jacket. 2. Loose the screws of cabling cavities cover. 3. Open the cover 4. Mount entry connector (water-proof type) on the DC-48V-IN port. Screws of cabling cavity Open the cover Mount entry connector on the DC-48V-IN port Figure 2-6 Preparation of the equipment 14/17 PMC CONFIDENTIAL PCS RRH List11 Installation Guide Issue: 1.0.0 5. Put power cable inside from the hole of entry connector 6. Loose cable fixing screws of terminal block 7. Insert each cable to th e suitable hole of terminal, according to the instruction of th e rear of the cover 8. Fix the terminal screws 10 in-lbs (1.13 Nm) Terminal block -48V RTN IN DC SUPPLY The hole of entry connecter RTN.I Put Power cable inside -48 DC SUPPLY RTN.I -48 Cable fixing screws Figure 2-7 Fixing Power cables 9. Fix the cable by entry connector 10. Close the cabling cavities cover 11. Fix the screws of cabling cavity’s cover xx Nm Cable fixing screws Close the cover Fix Power cable by entry connector Figure 2-8 Fixing Power cable and cover 15/17 PMC CONFIDENTIAL PCS RRH List11 Installation Guide Issue: 1.0.0 2.5 Powering On the RRH 1. Turn off the breaker of the power supply and connect the power supply cable. 2. Connect the other cables before turn on the breaker. 3. After start up the BBU, please turn on the power supply to RRH. 4. Please confirm the RRH start state with Status LED. 2.6 S tatus LED LED Display States No. S tate No Power Supplied Initial Power Supply External Power Supply Failure 4 Sof tware Download 5 No nrecoverable Critical Failure 6 Reco verable Critical Failure Slave CPRI Ling Failure 8 No n-Critical Nonrecoverable Failure 9 No n-Critical Recoverable Failure 10 External Antenna Failure 11 Normal Operation 12 S tandby LED Display Off Solid Red Flash Red Flash Yellow Solid Red Flasu Red Solid Yellow Solid Red Flash Red Flash Red Solid Green Flash Green 16/17 PMC CONFIDENTIAL PCS RRH List11 3 FCC Installation Guide Issue: 1.0.0 WARING Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Properly shielded an d grounded cabl es and conn ectors must b e used for connection to host computers and / or peripherals in order to meet FCC emission limits. Data transmission is always initi ated b y software, which is th e passed down through the MAC, through the digital and analog baseband, and finally to the RF chip. Several special packets are initiated by the MAC. These are the only ways the digital baseband portion will turn on th e RF tr ansmitter, which it then turns off at the end of the packet. Therefore, the transmitter will be on only while one of the aforementioned packets is being transmitted. In other words, this device automatically discontinue transmission in case of either absence of information to transmit or operational failure. Frequecncy Tolerance: 11 ppb This transmitter must not be co-located or operated in conjunction with any other antenna or transmitter. 17/17 PMC CONFIDENTIAL
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Author : nobu Create Date : 2011:08:23 21:58:53+09:00 Modify Date : 2011:09:06 11:52:47+09:00 XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Producer : Acrobat Distiller 9.4.5 (Windows) Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2011:09:06 11:52:47+09:00 Format : application/pdf Title : Microsoft Word - V050_110721_PCS RRH User Manual.doc Creator : nobu Document ID : uuid:fb87393d-f198-4c36-b9db-8c8a6eae21de Instance ID : uuid:4946bdf2-9496-4421-985b-852c26cc2359 Page Count : 17EXIF Metadata provided by EXIF.tools