Pantech HWT-2150 WLL Terminal ( CDMA ) User Manual CRN 9389 Q1 revised
Pantech Co., Ltd. WLL Terminal ( CDMA ) CRN 9389 Q1 revised
Pantech >
Contents
- 1. User manual
- 2. CRN 9389 Q1 revised user manual
- 3. CRN 11551 Page 41 of user manual
CRN 9389 Q1 revised user manual
hWT-2150(8-9) 2003.8.9 11:51 AM 페이지1 Contents Features of the Product ………………………………………………………………… 2 Before Using Supplementary functions Speed Dial ………………………………………………… Emergency call hold ……………………………………… Hot Line Service …………………………………………… Alarm Reminder …………………………………………… Lock ………………………………………………………… Ear-piece Volume Control ………………………………… Reset ……………………………………………………… Clip Setting ………………………………………………… Analog G3 Fax Standard Setting ………………………… Default Data Rate Setting ………………………………… Ringer Frequency & Candence Control ………………… Dial Tone Frequency Control …………………………… Default Vocoder Selection ……………………………… Timed Hot Line Dial Send Waiting Time Control ……… Hook Flash Time (Click Time) Control ………………… Voice Privacy Settng ……………………………………… Serial Interface Setting (None For HWT-2150) ………… A Key Value Input ………………………………………… Network Dial Tone Setting ……………………………… System Parameter Input ………………………………… Precautions in using ……………………………………… 5 Components Check ………………………………………… 6 Function Description of Each Component ……………… 7 Installation General installation…………………………………………… 9 Wall bracket Installation ……………………………………13 Installation for Data Service ………………………………15 Operation Power on ………………………………………………………16 Power off ………………………………………………………16 Call Send ………………………………………………………17 Call Receive ……………………………………………………17 Analog G3 fax service ……………………………………… 18 Data service …………………………………………………18 Appendix 21 22 24 25 26 27 27 28 29 30 31 32 33 33 34 35 35 38 38 37 Summary Table ……………………………………………… 39 Technical Specification …………………………………… 41 Troubleshooting……………………………………………… 42 Safety Safety Information ………………………………………… 43 hWT-2150(8-9) 2003.8.9 11:51 AM 페이지3 HWT-2150 3 Features of the Product User Guide Features of the Product First, clear voice quality - 13Kbps & EVRC Vocoder - Provides the same voice quality as that of the wired telephone service Second, elegant design and simple installation - Desktop & wall mounting structure provides simple installation at any place - Analog G3 Fax (Optional) - Pay Phone Interface (16KHz, 12KHz, Metering Pulse, Polarity Reversal) Fifty, extended call / waiting time - Adoption of up-to-date MSM5105 chip and super power-saving circuit design provides extended battery lifetime at a lower power consumption compared with other products. Third, varieties of supplementary services - System Dependent Feature : Caller ID, OTASP, Authentication, Voice mail Notification, Voice Privacy - Stand Alone Feature : Redial, Speed dialing(up to 99), Emergency Call Hold, Hot Line, Alarm Reminder - POTS (Plain Old Telephone Service), data, etc. Fourth, varieties of interfaces - Provides high speed digital data service at 64Kbps. - Circuit Data Communicate (file send/receive) - Support PC Fax (HotFax, WinFax) - Medium Data Rate Packet Data Support (Internet & FTP file send/receive) Sixth, varieties of tone / ring generators through simple setup - Simple setup of dial / warning tones (4 types) and call receiving alert rings (18 types) according to user's needs. hWT-2150(8-9) 2003.8.9 11:51 AM 페이지5 HWT-2150 5 User Guide Before Using B e f o re Using Precautions in using Do not disassemble or revise the FWT terminal at your discretion This product is the Fixed Wireless Terminal (FWT) designed using the up-to-date communication technology Code Division Multiple Do not touch the antenna during calling Access(CDMA) to fulfill superior communication services of users. Please, review this manual closely before using the product. Do not use the FWT terminal at hot and humid places. It may not be repairable if wet by rain or drinks Caution : As the backup battery of the FWT is not connected to the terminal upon delivery,make sure to connect it properly, referring to “General installation” of this manual. Avoid vibration or impact and keep the FWT terminal at a safe place to avoid damage while you are not using it Do not use the FWT terminal at a place where explosives or flammable liquids are present Do not wipe the FWT terminal with chemicals such as solvent Remove the SMPS and the backup battery if you do not use the FWT terminal for a long time hWT-2150(8-9) 2003.8.9 11:51 AM 페이지7 HWT-2150 7 User Guide Before Using Components check Function Description of Each Component Thank you for purchasing this product. Please check if the components of the product are consistent with the figure below : POWER LED SERVICE LED MODELED ANT. CHGLED FWT terminal Power supply (SMPS) Serial RJ-11 DC Jack Power Button • POWER LED Lighted when the external power is applied. - When the external power is applied, the LED is red. - When the internal power is applied, the LED is green. - If the backup battery is connected, you can use the terminal without the external power supply. • SERVICE LED Indicates status of the backup battery. - LED OFF : Indicates that the service is not available as the receive power intensity is weak. Antenna - LED blinking: Indicates that the service available although the receive power intensity is weak. - LED ON : Indicates that the receive power intensity is strong and the service is available. • MODE LED user Guide Fixation Nuts - RED : Indicates that the state is Voice Call. - Green : indicates that the state is Data Service. - Yellow : Indicates that the state is FAX Call. - LED OFF : Indicates that the state is stand by. hWT-2150(8-9) 2003.8.9 11:51 AM 페이지9 HWT-2150 9 User Guide Before Using • CHG LED - RED : indicates that the state is in Charging. • DC JACK Feeds power from the SMPS of the FWT terminal. - The AC input of the SMPS ranges 90~270V • SERIAL PORT A port for maintenance and data communication of the FWT terminal Installation General installation 1. Set the battery switch located at the bottom of the terminal to Off. 2. As shown in the figure below, open the cover on the rear side of the terminal by pushing it along the arrow. • RJ-11 JACK Used to connect normal phones. - As two jacks are presented, you can concurrently connect two telephones without security assured. - You may connect one telephone to any of the two jacks. - You may connect up to five telephones to RJ-11 jack. • POWER SWITCH Connects power to the FWT terminal. 3. After the cover is open, you can see the backup battery and its connector. As shown in the figure below, grip the connector to let the flat side look downward. Then, push the connector along the arrow to connect it to the circuit board. backup battery connector hWT-2150(8-9) 2003.8.9 11:51 AM 페이지11 10 HWT-2150 11 User Guide Installation Note: The terminal may be damaged if you attach the connector opposite to the direction shown above. Please double-check the direction and proceed to step 4 6. As shown in the figure below, connect the telephone (normal phone) to the jack RJ-11. You may use any of the two RJ-11 jacks provided by the terminal. 4. After connecting the battery connector to the circuit board, insert the cover as shown in the figure below. Then, fix the cover with the screws. 7. Connect the SMPS for FWT terminal to the DC-jack located on the left side of the terminal. Insert the power jack properly until it does not move further. 5. As shown in the figure below, insert the antenna along the arrow and rotate it clock-wise. hWT-2150(8-9) 2003.8.9 11:51 AM 페이지13 HWT-2150 13 12 User Guide Installation 8. Connect the power plug of the SMPS to the power receptacle. Wall bracket Installation 1. In case of concrete wall, attach the Installation Sheet to the place that you want and make holes with a drill. Wall AC plug (110V or 220V) Installation Sheet 25.0mm 9. Set the power switch located at the back of the terminal to ON. 2. As shown in the figure below, fix the screws into the holes. The following actions occur : •All of the four LEDs are lighted, and then the LED corresponding to the power currently applied is lighted. •If the service available, the SERVICE LED is lighted. Wall Screw 3.5mm ※ In case of wooden wall, skip drilling and directly fix the screws to the Installation Sheet. The distance from the wall to the head of the screw is the same as the figure in step 2. hWT-2150(8-9) 2003.8.9 11:51 AM 페이지15 HWT-2150 15 14 User Guide Installation 3. As shown in the figure below, insert A1 and A2 of the terminal to the head of the screw and press the terminal downward to fix it. Installation for data service Computer A1 A2 RS-232 Cable Telephone 4.The following figure shows the shape after completion of Installation. WLL TerminalWall Screw required to tighten the terminal to the wall. ※ You can get a batter call quality by installing the external panel antenna (Please contact the distributor of the product for the antenna). ※ The FWT terminal has a backup battery to run without the external power supply. If the SMPS for the FWT terminal is down, the terminal can run for about 15 hours in waiting state and for about 2 hours in call state with the backup battery. As shown in the figure above, connect the serial port of the FWT terminal to the PC COM1(COM2) with the RS232 cable. Data service subscribers can purchase the RS232 cable from the service provider. hWT-2150(8-9) 2003.8.9 11:51 AM 페이지17 HWT-2150 17 16 User Guide Operation Operation Power On - Using the external power Connect the SMPS to the DC-Jack located on the left side of the terminal and insert the power plug of the SMPS to the receptacle. Insert the power jack properly until it does not move further. If power is applied to the terminal, all of the four LEDs are lighted. Then, the power LED is lighted and the service LED is lighted if the service available. - Using the backup battery To use the backup battery of the terminal, set the battery switch at the bottom to On. If you want to use the backup battery, it has to be charged enough to operate the terminal. The battery is automatically charged when the external power is applied. If power is applied to the terminal, all of the three LEDs are lighted. Then, the battery LED located at the center is lighted and the service LED located at the bottom is lighted if the service available. Power Off Turn off the power switch located at the back of the terminal. Call Send - Normal Procedure ① Pick up the handset in on-hook status. You will hear the dial tone (In case of No Service, you will hear the warning tone with 0.5Sec interval). ② You can not send calls in No Service status (Service LED off). ③ Press the phone number of the called party and click the hook switch (Hook-Flash). ④ Speak to the called party when the line is connected. ⑤ Hang up the handset after conversation. - Redialing Used to call to the phone number called latest. ① Pick up the handset and click the hook switch. The line is connected to the number called latest. This function would not work if you tried no call after power on ② Pick up the handset and click the hook switch. Refer to section 4.7 for the click time. ③ Hang up the handset after conversation. - Speed Dialing Before using this service, you have to set the speed dial function. Refer to Section 4.1 for the setting method. ① In case of one digit If the speed dial is 01_09, pick up the handset, press the number (1_9), and then click the hook switch or press the latter digit long. Speak to the called party when the line is connected. Hang up the handset after conversation. ② In case of two digits If the speed dial is 10_99, pick up the handset, press the number (10_99), and then click the hook switch or press the first digit short and second digit long. Speak to the called party when the line is connected. Hang up the handset after conversation. hWT-2150(8-9) 2003.8.9 11:51 AM 페이지19 HWT-2150 19 18 User Guide Operation Call Receive - When the Normal Phone is On-hook State ① Pick up the handset when the normal phone rings. ② Speak to the called party when the line is connected. ③ Hang up the handset after conversation. - When the Normal Phone is Off-hook State ① Click the hook switch(hook-flash) if the normal phone receives the ring signal (Call receive in off-hook is allowed only if the dial tone & warning tone are being sent and the bell rings through the buzzer). ② Speak to the called party when the line is connected. ③ Hang up the handset after conversation Analog G3 Fax Service To use the analog G3 fax service from the terminal equipped with the analog G3 fax board, you have to send/receive documents according to the following procedure: - Sending Documents Press [✽00] and then press the number of destination. The other procedure is the same as that for general faxes. - Receiving Documents To receive documents from the analog G3 fax, set the terminal to the Analog G3 fax receive mode first. Pick up the handset of the fax and press [✽✽✽✽15✽]. The fax is set to the Analog G3 fax receive mode(Set to Analog G3 fax receive mode until power off). You can not receive voices unless you reset the Analog G3 fax receive mode. To reset the Analog G3 fax receive mode, pick up the handset of the fax and press [✽✽✽✽10✽] Data Service When a PC is connected to the WLL terminal, the data service can provide Internet and PC communication and fax send/receive. As wireless data communication service may not be provided depending on service providers, please check if the service provider provides this service. This service is available after purchasing data communication cable from the service provider. For computer environment setup and other details, refer to the User Manual provided when you purchase the data communication cable. - Data Service Receive Mode Setting •Setting with a normal phone This function is used to set the receive mode according to data service type, using the normal phone connected to the WLL terminal ① Pick up the handset of the normal phone and press [✽✽✽✽10✽] to reset the data service receive mode. ② Pick up the handset of the normal phone and press [✽✽✽✽11✽] to set fax receive mode(one time). The fax receive mode is released automatically 10 minutes after setting. ③ Pick up the handset of the normal phone and press [✽✽✽✽12✽] to set fax receive mode (Set to fax receive mode until power off). ④ Pick up the handset of the normal phone and press [✽✽✽✽13✽] to set modem receive mode(one time). The modem receive mode is released automatically 10 minutes after setting. ⑤ Pick up the handset of the normal phone and press [✽✽✽✽14✽] to set modem receive mode hWT-2150(8-9) 2003.8.9 11:51 AM 페이지21 HWT-2150 21 20 User Guide Operation (Set to modem receive mode until power off). ⑥ Default setting is [✽✽✽✽10✽]. •Setting with AT commands This function is used to set the receiving mode according to data service type,using the communication emulator program of PC connected to the WLL terminal. ① Enter [AT+QCVAD=0] in the communication emulator program and press the Enter key. ・After the setting is completed, OK is indicated and the data service receive mode is released. ② Enter [AT+QCVAD=1] in the communication emulator program and press the Enter key. ・After the setting is completed, OK is indicated and the fax receive mode (one time) is set. The fax receive mode is released automatically 10 minutes after setting. ③ Enter [AT+QCVAD=2] in the communication emulator program and press the Enter key. ・After the setting is completed, OK is indicated and the fax receive mode is set (Set to fax receive mode until power off). ④ Enter [AT+QCVAD=3] in the communication emulator program and press the Enter key. ・After the setting is completed, OK is indicated and the modem receive mode is set (one time). The modem receive mode is released automatically 10 minutes after setting. ⑤ Enter [AT+QCVAD=4] in the communication emulator program and press the Enter key. After the setting is completed, OK is indicated and the modem receive mode is set (Set to modem receive mode until power off). ⑥ Default setting is [AT+QCVAD=0]. Supplement Service Speed dial This function is used to save frequently used phone numbers in advance and make a phone call quickly with the abbreviated code. You can save up to 99 phone numbers. Default setting is off. - Save phone number Enter [##3233→1→1], enter a two-digit numbers(01~99) for the address to save the phone number and press the [✽] button(save). ##3233→1→1→address(2 digits)→phone numbers→✽ : save phone numbers - Delete phone number Enter [##3233→1→2], enter the address(01~99) to delete and press [✽] button. To delete all phone numbers saved, enter [##3233→1→ 3] and press the [✽] button. ##3233 → 1 → 2 → address(2 digits) → ✽ : delete one address ##3233 → 1 → 3 → ✽ : delete all address - Speed dial on and off Enter [##3233→1→4] and then press the [✽] button(on). The speed dial mode is enabled only if the speed dial function is on although phone numbers are saved in the memory. To disable the function(off), enter [##3233→1→ 5] and then press the [✽] button. hWT-2150(8-9) 2003.8.9 11:51 AM 페이지23 HWT-2150 23 22 User Guide Supplement Service ##3233 → 1 → 4 → ✽ : speed dial on ##3233 → 1 → 6 → ✽ : emergency call hold on ##3233 → 1 → 5 → ✽ : speed dial off ##3233 → 1 → 7 → ✽ : emergency call hold off - Speed Dialing If the phone number is saved in the address and the speed dial function is enabled(on), you can make a phone call by entering just the address. If the saved address is one digit(01~09), press the latter digit long or press it short and click the hook switch to make a phone call to the saved number. If the saved address is two digits(10~99), press the first digit short and the second digit long or press the two digits short and click the hook switch to make a phone call to the saved number. If you attempt a call while the speed dial function is off, you will hear the reject tone and fail to make a phone call. - Emergency call When phone numbers are stored in address 01~03 and the emergency call is on, if you press the latter digits of the address long or two digits short and click the hook switch, the call is connected to the stored number and is held on as long as the called party does not release. If you attempt speed dialing when emergency call hold and speed dial are enabled concurrently, the address 01~03 are operated in emergency call hold mode. If you attempt speed dialing when emergency call hold is off and speed dial is on, the address 01~03 are operated in speed dial mode. Reference: Warning Tone/Howler(ROH:Receiver Off-Hook) Tone Emergency call hold This function is used to register up to three phone numbers(Address 01~03) in advance to prepare for emergencies and quickly make a phone call with the speed dial. The line connected is held on as long as the called party does not release. Default setting is off. - Emergency call hold on and off Enter [##3233 → 1 → 6] and press [✽] button(on). The emergency call hold function is activated when phone numbers are saved in address 01~03 and the emergency call is on. You can save phone numbers in address 01~03 in the same way as "4.1.1" . To deactivate the emergency call hold function(off), enter [##3233 → 1 → 7] and press the [✽] button. If you pick up the handset (Off-Hook) and do not press buttons for the given time, the dial tone changes to the warning tone. At this time, you can receive calls but can not send calls as number input is not allowed. In this case, you have to put back the handset (On-Hook) and pick it up again (Off-Hook) to attempt a call. If you hold the handset after the dial tone has changed to the warning tone, the warning tone changes to the Howler (ROH) Tone after the given time. You can hear the Howler Tone through the buzzer. From that time on, you can not send or receive calls until you hang up (OnHook) the handset. Reference: Confirmation Tone/Reject Tone If you press the [✽] button(save) after all key operation for supplementary service setting is normally accomplished, the telephone returns to the initial status after hookoff and the Confirmation Tone is sent to notify that the setting has been accomplished normally. If an incorrect key is entered, a short reject tone is sent to notify the error. Then, you can continue the operation from that step. hWT-2150(8-9) 2003.8.9 11:51 AM 페이지25 HWT-2150 25 24 User Guide Supplement Service Hot Line Service This function is used to register one frequently used number (address 99) in advance and automatically make a phone call to the number after hook-off. Default setting is Off. Hot line is operated in 2 modes; timed hot line mode to connect the line after the specified time (4sec~8sec) and immediate hot line mode to connect the line just after off-hook. - Hot line on and off Enter [##3233→1→8→1].and press the [✽] button to set timed hot line(On). If a phone number is saved in addess 99 and the hot line function is set to timed hot line mode, the line is connected the dial send time (4sec~8sec) after hook-off. Also, enter [##3233→1→8→2].and press the [✽] button to set dial send time(4sec~8sec) after hook-off. Also, if a phone number is saved in address 99 and the hot line function is set to immediate hot line mode, the line is connected just after hook-off. Reference: When immediate hot line is on, you can not send calls to other numbers. To make a phone call to other number, enter the setup mode by pressing the [#] button within one second after hook-off and change the hot line mode. Alarm reminder If you set a time in advance, the alarm rings on the specified time and stops when you pick up the handset. Default setting is off. - Alarm reminder on and off Enter [##3233→2→1] and four digits for a desired time(24 hours) and immediate hot line(On). press the [✽] button(on). If a phone number is saved in address 99 and the hot line function The alarm reminder function is automatically set to one time. The is set to immediate hot line mode, the line is connected just after alarm rings on the specified time and then the alarm reminder is hook- off. released (off). If you want to activate the alarm at the same time everyday, enter ##3233 → 1 → 8 → 1 →✽ : Timed hot line on [##3233→2→3→✽] to activate the alarm reminder and enter ##3233 → 1 → 8 → 2→✽ : Immediate hot line on [##3233→2→4→✽] to deactivate it. ##3233 → 1 → 8 → 3→✽ : Hot line off - Hot line calling If a phone number is saved in address 99 and the hot line function is set to timed hot line mode, the line is connected the ##3233 → 2 → 1 → Hour(4 digits, 24 hours) → ✽ : Alarm time input and setting (one time) ##3233 → 2 → 2 → ✽ : Alarm reminder on (one time) ##3233 → 2 → 3 → ✽ : Alarm reminder on (always) ##3233 → 2 → 4 → ✽ : Alarm reminder off hWT-2150(8-9) 2003.8.9 11:51 AM 페이지27 HWT-2150 27 26 User Guide Supplement Service Ear-piece volume control Lock This function is used to enter a password into the terminal to reject calls from users who are not aware of the password. If you attempt a call when the lock function is on, the warning tone is heard and the call is not connected (Call receive is allowed). H o w e v e r, if the emergency call function is on, origination of emergency calls (address 01~03) is allowed. Default setting is off. - Lock on and off Enter [##3233→3] and a password of four digits. If you enter an incorrect password, you will hear the reject tone. If the correct password is entered, press [1] and then the [✽] button(lock on). To release the lock function, enter [##3233→3→password→2→✽]. ##3233 → 3 → password → 1 → ✽ : Locking on ##3233 → 3 → password → 2 → ✽ : Locking off Used to control the volume of ear-piece. Default setting is Level3 [#### 03]. - Ear-piece volume control method ① Enter [##3233 → 4 → 1], enter a desired button out of 1(level 1), 2(level 2), 3(level 3), 4(level 4), 5(level 5), and then press the [✽] button to save. "1" is the smallest volume. The bigger the number is, the larger the volume is. ##3233→4→1→1~5→✽ : Ear-piece volume(Method 1) ② Pick up the handset of the normal phone and press [####]. Enter a desired number out of 01~05, and then press the [✽] button to save. You will hear the dial tone after the volume control is completed. #### → 01~05 → ✽ : Ear-piece volume control (method 2) - Password change To change the password, press [##3233→3] and then enter the password. Press[3], enter a new password and press the [✽]button. Enter the new password again and press the [✽] button to change the password to the new one. ##3233 → 3 → password → 3→new password →✽→new password→✽ : change password Reference: The default password for lock is "0000". Reset Used to reset the terminal setup. - Reset method ① Enter [##3233→4→0] and the lock code or the maintenance code and then press [✽] button. ##3233 → 4 → 0 → ✽ : Reset hWT-2150(8-9) 2003.8.9 11:51 AM 페이지29 HWT-2150 29 28 User Guide Supplement Service Analog G3 Fax Standard Setting Reset items and their status are listed below: The terminal can provide fax service using two types of Analog G3 Items Status Speed dial off Emergency call hold off Hot line call off Alarm off Lock off PC Fax standard or the IS-707A.7 Analog G3 Fax standard. When Ear-piece volume level 3 IS-99/IS-707.4 based PC Fax standard is used, you have to select CLIP Setting As the terminal type FWT has no display, the calling party’s number can be indicated by connecting a specific module or a display type Fax standards. This function is used to set the standard. - Analog G3 Fax Standard Setting Analog G3 Fax service is provided using the IS-99/IS-707.4 based the default Fax receiving mode. ① IS-99/707.4 PC Fax setting Enter [##3233 → 5 → Maintenance Code → 2 → 1], select “1” (PC fax) or “2” (Analog G3 Fax), and then press the [✽] button to save. telephone. This function is used to set communication method of the module. ##3233 → 5 → Maintenance Code → 2 → 1 → 1 or 2 →✽ : IS-99/707.4 PC Fax based mode setting - CLIP Setting Method ① Enter [##3233 → 5 → Maintenance Code → 1 → 1(DTMF mode) or 2 (FSK mode)] and press the [✽] button to save. Reference: Default receiving mode is system-dependent (Unnecessary depending on system configuration.). If the system is configured with single DN, the default receiving ##3233 → 5 → Maintenance Code → 1 → 1 or 2→ ✽ : CLIP setting mode is not applied as Fax receiving depends on user’s receive mode setting (Data receiving through the analog G3 Fax in case of ****15* and through the PC in case of ****12*). Also, if the system is configured with two DNs (if fax calls are received Reference: The Maintenance Code “2733” is used only for maintenance. according to the service option determined by the system), the terminal receives calls according to the default receiving mode setting. hWT-2150(8-9) 2003.8.9 11:51 AM 페이지31 HWT-2150 31 30 User Guide Supplement Service ② IS-707A.7 Analog G3 Fax standard setting. Enter [##3233 → 5 → Maintenance Code → 2 → 2] and press the [✽]button to save. ##3233 → 5 → Maintenance Code → 2 → 2 → ✽ : IS-707A.7 Analog G3 Fax standard setting Default Data Rate Setting The terminal supports two types of data rates according to the ③ Setting IS-707.4 Rate Set 1 : Enter [##3233 → 5 → Maintenance Code → 3], select “3”, and then press the [✽] button to save. ##3233 → 5 → Maintenance Code → 3 → 3 →✽ : Setting default data rate to RS1(IS-707.4 based) ④ Setting IS-707.4 Rate Set 2 : Enter [##3233 → 5 → Maintenance Code → 4], select “4”, and then press the [✽] button to save. ##3233 → 5 → Maintenance Code → 3 → 4 →✽ : Setting default data rate to RS2(IS-707.4 based) standards. This function is used to set the default rate for data calls. - Default Data Rate Setting ① Setting IS-99 Rate Set 1 : Enter [##3233 → 5 → Maintenance Code → 3], select “1”, and then press the [✽] button to save. ##3233 → 5 → Maintenance Code → 3 → 1 → ✽ : Setting default data rate (8K) to RS1 (IS99) ② Setting IS-99 Rate Set 2: Enter [##3233 → 5 → Maintenance Code → 3], select “2”, and then press the [✽] button to save. ##3233 → 5 → Maintenance Code → 3 → 2 → ✽ : Setting default data rate to RS2 (IS-99 based) Ringer Frequency & Cadence Control This function is used to control the ringer frequency and cadence. Select the frequency first and then select the cadence. Default setting is 20Hz, 1 sec On – 2sec Off. - Ringer Frequency Setting Enter [##3233 → 5 → Maintenance Code → 4]. Select a desired number from 1 (16Hz) , 2 (20Hz) and 3 (25Hz). - Ringer Cadence Setting After selecting the frequency, select the cadence. Select a desired number from 1~ 6 and press the * button to terminate ringer frequency and ringer cadence setting. No. 1: 1Sec On – 2 Sec Off No. 2: 0.4 Sec On – 0.2 Sec Off - 0.4 Sec On – 2 Sec Off No. 3: 1 Sec On – 4.5 Sec Off No. 4: 1 Sec On – 4 Sec Off hWT-2150(8-9) 2003.8.9 11:51 AM 페이지33 HWT-2150 33 32 User Guide Supplement Service No. 5: 0.25 Sec On – 0.25 Sec Off - 0.25 Sec On – 1.25 Sec Off No. 6: 2 Sec On – 4 Sec Off ##3233 → 4 → 3 → 1~3(frequency) → 1~6(cadence) →✽ : Ringer frequency & cadence setting Default Vocoder Selection The terminal provides service with three Vocorder types. This function is used to select the Vocorder type. - Vocoder Selection Method Enter [##3233 → 5 → Maintenance Code → 6], select one of “1” Dial Tone Frequency Control This function is used to select the dial sent from the handset. Default setting is 350 + 440Hz dual tone. (8K EVRC) or “2” (13K QCELP) and then press the [✽] button to save. ##3233 → 5 → Maintenance Code → 6 → 1 or 2 → ✽ : Vocoder selection - Dial Tone Frequency Control Method ① Enter [##3233 → 5 → Maintenance Code → 5]. Select a desired number from 1 (350+440Hz) , 2 (400Hz) , 3 (425Hz) and 4 (450Hz) and press the [✽] button. ##3233 → 5 → Maintenance Code → 5 → 1~4 → ✽ : Dial Tone Frequency Control (Method 1) ② Pick up the handset of the normal phone, press [####], and enter a desired number out of 51 (350+440Hz) , 52(400Hz) , 53(425Hz) and 54(450Hz). #### → 51~54 : Dial Tone Frequency Control (Method 2) Timed Hot Line Dial Send Waiting Time Control This function is used to control the hot line number send time when the Timed Hot Line is On. The Hot Line number send time is adjustable from 4 sec to 8 sec and default setting is 6 sec. - Timed Hot Line Dial Send Waiting Time Setting ① Enter [##3233 → 5 → Maintenance Code → 7]. Select a desired number from 4 , 5 , 6 , 7 and 8 and press the [✽] button. For example, to set 7 sec, press 7 and the [✽] button. ##3233 → 5 → Maintenance Code → 7 → 4~8 →✽ : Timed Hot Line Dial send time setting (Method 1) hWT-2150(8-9) 2003.8.9 11:51 AM 페이지35 HWT-2150 35 34 User Guide Supplement Service ② Pick up the handset of the normal phone, press [####], and then select a desired number from 04~08. ‘04’ indicates automatic call send after 4 seconds and ‘08’ indicates automatic call send after eight seconds. #### → 04~08 : Timed Hot Line Dial send time setting (Method 2) Voice Privacy Setting The terminal supports voice privacy. - Voice Privacy On Enter [##3233 → 5 → Maintenance Code → 9 → 1] and press the [✽] button to save. - Voice Privacy Off Hook Flash Time (Click Time) Control Enter [##3233 → 5 → Maintenance Code → 9 → 2] and press the [✽] button to save. This function is used to set the time required to recognize click of the hook switch for redial and speed dial. Default setting is 100-700ms. ##3233 → 5 → Maintenance Code → 9 → 1 or 2 → ✽ : Voice Privacy on/off - Hook Flash Time Control Method ① Enter [##3233 → 5 → Maintenance Code → 8 → 1], enter two digits (05~98) for the minimum time by the 10msec, and then press the [✽] button to save. ##3233 → 5 → Maintenance Code → 8 → 1 → 05~98 → ✽ : Hook Flash minimum time setting ② Enter [##3233 → 5 → Maintenance Code → 8 → 2], enter two digits (06~99) for the maximum time by the 10msec, and then press the [✽] button to save. ##3233 → 5 → Maintenance Code → 8 → 2 → 06~99 → ✽ : Hook Flash maximum time setting Reference: If the minimum time is set to 50 ~ 90 msec, it is not available for dial pulse type telephones. Serial Interface Setting (None for HWP-2150) The terminal supports data serve when it is connected to the PC through RS-232 serial interface. The HWT-2150 terminal provides two data rates for PC interface. It provides 115200 bps for highspeed packet data service and 19200 bps for modem, PC Fax and low speed packet data service. - Setting serial interface to 19200 bps ① Enter [##3233 → 5 → Maintenance Code → 0, select “1”], and then press the [✽] button to save. ##3233 → 5 → Maintenance Code → 0 → 1 → ✽ : Setting the serial data baudrate to 19200 bps hWT-2150(8-9) 2003.8.9 11:51 AM 페이지37 HWT-2150 37 36 User Guide Supplement Service - Network Dial Tone Off - Setting Serial Interface to 115200 bps Enter [##3233 → 5 → Maintenance Code → 0, select “2”], and then press the [✽] button to save. Enter [##3233 → 6 → Maintenance Code → 2, select “1”], and then press the [✽] button to save. ##3233 → 6 → Maintenance Code → 2 → 1 → ✽ ##3233 → 5 → Maintenance Code → 0 → 2 →✽ : NIU-generated dial tone setting : Setting the serial data baudrate to 115200 bps - Network Dial Tone On A Key Value Input Enter [##3233 → 6 → Maintenance Code → 2, select “2”], and then The terminal supports OTASP service that requires authentication. This function is used to enter A key value required for the authentication procedure. press the [✽] button to save. ##3233 → 6 → Maintenance Code → 2 → 2 → ✽ : LE-Generated dial tone setting - A Key Input Enter [##3233 → 6 → Maintenance Code → 1], enter a number corresponding to the A Key value up to 26 digits, and then press the [✽]button to save. ##3233 → 6 → Maintenance Code → 1 → System Parameter Input You can enter/change channel number and MIN number of the system parameters with the handset. - Channel Number Input A Key No.(26 digits) → ✽ : A Key input Network Dial Tone Setting The terminal provides the network dial tone depending on configuration of the system (system dependent). The terminal connected to a system that provides the network dial tone provides “LE-Generated dial tone”. Other systems provide “NIU-generated dial tone”. Enter ##3233 → 9 → Maintenance Code → 1~4, enter three digits of the channel number, and then press the [✽] button to save. 1 : Primary System A channel 2 : Secondary System A channel 3 : Primary System B channel 4 : Secondary System B channel ##3233 → 9 → Maintenance Code → 1~4 → Channel No. → ✽ : Channel number input hWT-2150(8-9) 2003.8.9 11:51 AM 페이지39 HWT-2150 39 38 User Guide Supplement Service - MIN Number Input Enter ##3233 → 9 → Maintenance Code → 5, enter up to ten digits for the MIN number, and then press the [✽] button to save. ##3233 → 9 → Maintenance Code → 5 → MIN No. → ✽ : MIN number input Appendix Summary table ##3233→1→1→address→phone number ##3233→1→2→address→✽ ##3233→1→3→ ✽ ##3233→1→4→ ✽ ##3233→1→5→ ✽ ##3233→1→6→ ✽ ##3233→1→7→ ✽ ##3233→1→8→1→✽ ##3233→1→8→2→✽ ##3233→1→8→3→✽ ##3233→2→1→hour(4 digits, 24 hours) → ✽ ##3233→2→2→ ✽ ##3233→2→3→ ✽ ##3233→2→4→ ✽ ##3233→3→password→1→ ✽ On ##3233→3→password→2→ ✽ Off Lock # # 3 2 3 3→3→password→3→New password→ ✽→ Change password new password→ ✽ Ear-piece volume # # # #→ 01/02/03/04/05 → ✽ (01:Min ← 03:Middle → 0 5 : M a x ) adjusting ( 5 steps) # # 3 2 3 3→ 4→1→ 1 ~ 5→ ✽ ( 1 ~ 5 : s t e p 1 ~ s t e p 5 ) Reset # # 3 2 3 3→ 4→0→ p a s s w o r d→ ✽ ##3233 → 5 → Maintenance Code → 1 → 1 / 2 → ✽ Clip setting ( 1 : DTMF(BINA) Mode, 2 : FSK Bellcore Mode) IS-99/707.4 PC ##3233 → 5 → Maintenance Code → 2 → 1 → 1 / 2 → ✽ Analog G3 Fax Fax Mode ( 1 : PC Fax receiving default , 2 : Analog G3 receiving default ) Standard Setting IS-707A.7 Mode ##3233 → 5 → Maintenance Code → 2 → 2 → ✽ ##3233 → 5 → Maintenance Code → 3 → 1 / 2 / 3 / 4 → ✽ Default Rate Set Save Save/delete Delete one address phone number Delete all addresses On Speed dialing Off Emergency call On Off hold Time hot line on Hot line Immediate hot line Off Time input(one time) One time mode Alarm reminder Always mode Alarm off (1 : RS 1 (IS99) , 2 : RS 2(IS99) , 3 : RS 1(IS707.4) , 2 : Rate Set 2 (IS707.4)) Ringer Frequency & Cadence Control ##3233 → 5 → Maintenance Code → 4 → 1 / 2 / 3 (frequency) → 1 / 2 / 3 / 4 / 5 / 6 (cadence) → ✽ Dial Tone Frequency Control ##3233 → 5 → Maintenance Code → 5 → 1 / 2 / 3 / 4 → ✽ ( 1: 350+440Hz 2: 400Hz 3: 425Hz 4: 450Hz ) (Frequency 1: 16Hz 2: 20Hz 3: 25Hz / Cadence 1,2,3,4,5, 6 : Refer to 4.8.2) hWT-2150(8-9) 2003.8.9 11:51 AM 페이지41 HWT-2150 41 40 User Guide Appendix ##3233 → 5 → Maintenance Code → 6 → 1/ 2 →✽ ( 1 : 8K EVRC , 2 : 13K QCELP ) Timed Hot Line Dial ##3233 → 5 → Maintenance Code → 7 → 4 / 5 / 6 / 7 / 8 → ✽ Send Waiting Tim ( 4: 4 Sec 5: 5 Sec 6: 6 Sec 7: 7 Sec 8: 8 Sec ) Default Vocoder S.O Hook Flash Time Control Technical Specification - 800MHz ##3233 → 5 → Maintenance Code → 8 → 1 (Min time) → 05~98 →✽ ##3233 → 5 → Maintenance Code → 8 → 2 (Max time) → 06~99 →✽ ( 05 ~ 99 : 50 msec ~ 990 msec) On ##3233 → 5 → Maintenance Code → 9 → 1 →✽ Voice Privacy Off ##3233 → 5 → Maintenance Code → 9 → 2 →✽ ##3233 → 5 → Maintenance Code → 0 → 1 →✽ Serial Interface 19200 bps Setting 115200 bps ##3233 → 5 → Maintenance Code → 0 → 2 →✽ A Key Value ##3233 → 6 → Maintenance Code → 1 → “AKEY” (26 digits) → ✽ ( AKEY : 26-digit A Key value) Input NIU-generated Dial Tone ##3233 → 6 → Maintenance Code → 1 → 1 → ✽ Network Dial Tone LE-generated Dial Tone ##3233 → 6 → Maintenance Code → 1 → 2 → ✽ Air Interface ##3233→9→Maintenance Code→1(Primary A CH No.) →www (3digits)→✽ ( www : Primary System A Channel No.) ##3233→9→Maintenance Code→2(Secondary A CH No.)→xxx (3digits)→✽ ( xxx : Secondary System A Channel No.) Channel Number Input ##3233→9→Maintenance Code→3(Primary B CH No.)→yyy (3digits) →✽ ( yyy : Primary System B Channel No.) ##3233→9→Maintenance Code→4(Secondary B CH No.)→zzz (3digits)→✽ MIN Number Input Analog G3 fax receive Data service receive mode release Fax receive mode setting (one time) Fax receive mode setting(until power off) Modem receive mode (one time) Modem receive mode(until power off) ( zzz : Secondary System B Channel No.) ##3233→9→Maintenance Code→5→xxxxxxxxxx (10digits)→ ✽ ( xxxxxxxxxx : MIN No.) On (fax receive) ✽✽✽✽15✽ Off (voice receive) ✽✽✽✽10✽ ✽✽✽✽10✽ Using the normal phone [AT+QCVAD=0] → Enter key Using the emulator ✽✽✽✽ 11✽ Using the normal phone Using the emulator [AT+QCVAD=1] → Enter key Using the normal phone ✽✽✽✽12✽ [AT+QCVAD=2] → Enter key Using the emulator Using the normal phone ✽✽✽✽13✽ Using the emulator [AT+QCVAD=3] → Enter key Using the normal phone ✽✽✽✽14✽ [AT+QCVAD=4] → Enter key Using the emulator Battery Back-up Connectors for various Service support Physical Environmental Power Supply Accessories Common air interface standard → IS-2000 FREQUENCY → TX : 824 – 849MHz RX : 869 – 894MHz TX Output Power → 200mW RX Sensitivity → - 104dBm Vocoder → 8K/13K QCELP, 8K EVRC Channel Bandwidth → CDMA 1.25Mhz Spurious → TX : -61dBm below RX : -81dBm below MOD/DEMOD → O QPSK/QPSK Frequency Accuracy → Fo°w300Hz Type → Ni-MH Capacity → 3.6V @ 1.8A Talk Time → 2 Hours Standby Time → 20Hours RJ-11 → Standard wire-line telephone Analog G3 Fax (Optional) Serial port → Maintenance Purpose Data Service Purpose ( Internet, PC Fax) Dimension(D x W x H) → 180 x 180 x 57mm Weight ( including Backup battery) → 546g Operating Temperature → -10°C ~ +50°C Storage Temperature → -20°C ~ +70°C Input Power → 100 ~ 240Vw10%, 48~62Hz Output Power → 5.5V 1.2A Internal Antenna → Di-Pole Antenna Power supply External Antenna ( Optional ) → 10dbi Gain Directional Panel Antenna hWT-2150(8-9) 2003.8.9 11:51 AM 페이지43 HWT-2150 43 42 User Guide Appendix Safety Information 1. SAFETY INFORMATION FOR FIXED WIRELESS TERMINALS Troubleshooting Trouble Actions When you hear no sound after hook-off? •Check if the power LED or battery LED of the terminal is on. If off, check if the SMPS power plug is properly connected to the terminal. •Check the RJ-11 Jack of the terminal connected to the telephone. When the service LED blinks or goes off? •Check if the antenna is connected correctly, or move the location of the terminal and check if the service LED is on. When you hear the warning tone instead of the dial tone after hook-off? •Check if the antenna is connected correctly, or move the location of the terminal and check if the service LED is on. When the warning tone sounds"beep beep" when you attempts a call? •No call channel available or communication failure with the base station. check if the service LED is on and try again. When calls are not connected with the warning tone but you can receive calls? •The lock function is on. Refer to section 'Ear-piece Volume control' of the user guide. •If you are not aware of the password, please contact the distributor or the service center. When voice resounds during conversation? •The resound removing function of the base station is set improperly. Refer to section 'Ear-piece Volume control' of the user guide for volume control. When voice of the other party is not clear? •Refer to section 'Ear-piece Volume control' of the user guide. When the battery LED blinks or goes off while you are operating the terminal with the battery? •Charge the backup battery with the SMPS as the battery is discharged. •POTENTIALLY EXPLOSIVE ATMOSPHERES Turn your phone OFF when in any area with a potentially explosive atmosphere and obey all signs and instructions.Sparks in such areas could caus e an explosion or fire resulting in bodily injury or even death. •INTERFERENCE TO MEDICAL DIVICES Certain electronic equipment may be shielded against RF signal from you wireless phone.(pacemakers,Hearing Aids,and so on) Turn your phone OFF in health care facilities when any regulations posted in these areas instruct you to do so. RF signals may affect improperly installed or inadequately shielded electronic system in motor vehicles. •EXPOSURE TO RF ENERGY Use only the supplied or an approved replacement antenna. Do not touch the antenna unnecessarily when the phone is in use. Do not move the antenna close to, or touching any exposed part of the body when making a call. 2. SAR INFORMATION THIS MODEL PHONE MEETS THE GOVERNMENT ’S REQUIREMENTS FOR EXPOSURE TO RADIO WAVES. Your wireless phone is a radio transmitter and receiver.It is designed and manufactured not to exceed the emission limits for exposure to radio frequency (RF)energy set by the Federal Communications Commission of the U.S.Government.These limits are part of comprehensive guidelines and establish permitted levels of RF energy for the general population.The guidelines are based on standards that were developed by independent scientific organizations through periodic and thorough evaluation of scientific studies. The standards include a substantial safety margin designed to assure the safety of all persons,regardless of age and health. hWT-2150(8-9) 2003.8.9 11:51 AM 페이지45 44 Safety The exposure standard for wireless mobile phones employs a unit of measurement known as the Specific Absorption Rate,or SAR.The SAR limit set by the FCC is 1.6 W/kg.*Tests for SAR are conducted with the phone transmitting at its highest certified power level in all tested frequency bands.Although the SAR is determined at the highest certified power level,the actual SAR level of the phone while operating can be well below the maximum value.This is because the phone is designed to operate at multiple power levels so as to use only the power required to reach the network.In general,the closer you are to a wireless base station antenna,the lower the power output. Before a phone model is available for sale to the public, it must be tested and certified to the FCC that it does not exceed the limit established by the government-adopted requirement for safe exposure. The tests are performed in positions and locations (e.g., at the ear and worn on the body) as required by the FCC for each model. The highest SAR value for this model phone when worn on the body with 2.5 cm separation distance as described in this user guide, is 0.808 W/kg. (Body worn measurements differ among phone models, depending upon available accessories and FCC requirements). While there may be differences between the SAR levels of various phones and at various positions, they all meet the government requirement for safe exposure. The FCC has granted an Equipment Authorization for this model phone with all reported SAR levels evaluated as in compliance with the FCC RF exposure guidelines.SAR information on this model phone is on file with the FCC and can be found under the Display Grant section of http://www.fcc.gov/oet/fccid after searching on FCC ID PP4HWT-2150. Additional information on Specific Absorption Rates (SAR)can be found on the Cellular Telecommunications &Internet Association (CTIA)web-site at http://phonefacts.net.*In the United States and Canada,the SAR limit for mobile phones used by the public is 1.6 watts/kg (W/kg)averaged over one gram of tissue.The standard incorporates a substantial margin of safety to give additional protection for the public and to account for any variations in measurements.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Create Date : 2003:08:09 11:51:22Z Modify Date : 2004:02:16 23:29:23-08:00 Page Count : 23 Creation Date : 2003:08:09 11:51:22Z Author : 1 Producer : Power Macintosh¿ë Acrobat PDFWriter 4.0 Mod Date : 2004:02:16 23:29:23-08:00 Metadata Date : 2004:02:16 23:29:23-08:00 Creator : 1EXIF Metadata provided by EXIF.tools