Replacement DC Power Entry Module
for the 8820 Broadband Access Concentrator
Models 8820-S2-903 and 8820-S1-906
Installation Instructions
Document Number 8820-A2-GZ45-20
October 2004

DC Power Entry Module for the 8820 BAC
The plug-in Power Entry Module (PEM) is used in the 8820 Broadband Access
Concentrator (BAC), model 8820-A2-5xx, to provide 48 V or 60 V power isolation
and distribution, overcurrent protection, and power filtering and monitoring. The
Model 8820-S2-903 PEM accepts –48 VDC, and the Model 8820-S1-906 PEM
accepts –48 VDC or –60 VDC.

POWER
A

SYS

ALARMS

B

Fan Major Minor

TEM
SYSTEM

OK
Alm

OK

Test

Alm
Test

ETHERN

ET
ETHERNET

TX
RX

TX

Coll

RX
Coll

DSL

POR
T
1
2
3
4

DISCONNECTED AT THE SOURCE
BEFORE REMOVING OR INSTALLING
THIS PWR ENTRY MODULE

POWER ENTRY MODULE
LEFT UNIT: LINE A
RIGHT UNIT: LINE B

48V NEG

POWER ENTRY MODULE
LEFT UNIT: LINE A
RIGHT UNIT: LINE B

WARNING! POWER MUST BE

48V NEG

MCP

48V RTN

Power
Entry
Modules

48V RTN

DSL

CLOCK SERIAL
AC
A
MCC ALARM

2

4

6

8

B
SERIAL ALARM
CLOCK SMCM

1

3

5

7

LAN/WAN SLOT
A
10

12

14

16

18

11

13

15

17

WARNING! POWER MUST BE

DISCONNECTED AT THE SOURCE
BEFORE REMOVING OR INSTALLING
THIS PWR ENTRY MODULE

9

B

00-16543-01

Figure 1. 8820 Broadband Access Concentrator
The 8820 BAC is shipped with two PEMs installed.
The PEM consists of a printed wiring board (PWB) attached to an L–shaped
faceplate. The PWB holds the electronic circuitry, including a faceplate–mounted
circuit breaker and power input connectors. The PEMs mate with connectors on
the backplane of the BAC. The L–shaped faceplate provides a shelf for dressing
and protecting the wiring and serves as a handle for insertion and removal.
Two PEMs (with separately fused power sources) are always required to provide
power redundancy. When installed in the chassis:

8820-A2-GZ45-20

„

The module on the left is identified as PEM A and handles the A power source.

„

The module on the right is identified as PEM B and handles the B power
source.

October 2004

1

Wiring the PEM
HANDLING PRECAUTIONS FOR
! STATIC-SENSITIVE DEVICES
This product is designed to protect sensitive components from damage
due to electrostatic discharge (ESD) during normal operation. When
performing installation procedures, however, take proper static control
precautions to prevent damage to equipment. If you are not sure of the
proper static control precautions, contact your nearest sales or service
representative.

Each PEM is equipped with an internal 35 amp (Model 8820-S2-903) or 40 amp
(Model 8820-S1-906) circuit breaker. Two separate, unswitched, individually fused
power sources, each capable of safely handling this load, are required for power
redundancy.
The PEMs require 8 AWG wire for their power connections. If stranded wire is
used, do not solder–coat the ends of the wires as this could weaken the
connections.
Although power may be connected to the front of the PEMs, it is recommended
that these connections be made at the rear of the chassis. Either way will work, but
all power inputs must be made either to the front or to the rear of the chassis, not
both.

NOTE:

POWER ENTRY MODULE
LEFT UNIT: LINE A
RIGHT UNIT: LINE B

CLOCK SERIAL
AC
A
MCC ALARM

2

4

6

8

B
SERIAL ALARM
CLOCK SMCM

1

3

5

7

LAN/WAN SLOT
A
10

12

14

16

18

11

13

15

17

WARNING! POWER MUST BE

DISCONNECTED AT THE SOURCE
BEFORE REMOVING OR INSTALLING
THIS PWR ENTRY MODULE

B

48V RTN

PEM PEM
A
B

9

POWER ENTRY MODULE
LEFT UNIT: LINE A
RIGHT UNIT: LINE B

PEM
Circuit
Breaker

48V NEG

DISCONNECTED AT THE SOURCE
BEFORE REMOVING OR INSTALLING
THIS PWR ENTRY MODULE

48V NEG

48V NEG

POWER ENTRY MODULE
LEFT UNIT: LINE A
RIGHT UNIT: LINE B

WARNING! POWER MUST BE

48V RTN

48V RTN

Both PWR A and PWR B must be powered, else the management card alarm
will be activated.

O
WARNING! POWER MUST BE DISCONNECTED AT THE SOURCE
BEFORE REMOVING OR INSTALLING THIS PWR ENTRY MODULE

00-15326a-02

Figure 2. PEM with Internal Power Terminals

2

October 2004

8820-A2-GZ45-20

! WARNINGS:
„

It is recommended that the following procedure be performed by a
qualified electrician.

„

The 48 VDC or 60 VDC power must be disconnected at its source before
attempting to connect wiring to the PEM. Do not remove wired PEMs
without first disconnecting the power at its source.

You need a Phillips screwdriver to remove the PEM from the BAC.

Removing the PEM from the BAC
Procedure
1. Ensure that the power is disconnected at the source.
2. Open the PEM circuit breaker (power off).
3. Remove the PEM to be wired from the chassis by unfastening the two screws
from the PEM faceplate. Save these screws since they will be needed when
the wired PEM is reinstalled into the chassis.
M4 Phillips-head
Screw

POW
ER E
LEF NTRY M
T
RIGH UNIT: ODULE
T UN LINE
IT: L A
INE
B

WAR
BEFONING! PO
RE R

O

48V NEG

48V RTN

Ring Tongue
Terminal

Power Tap

W
EMOV ER MUS
ING O T BE D
R INS ISCO
TALL NNEC
ING T
T
HIS P ED AT TH
WR E
E
NTRY SOURCE
MOD
ULE

00-16713

4. Grasp the flange on the extended shelf at the bottom of the PEM faceplate.
5. Pull the module toward you until it is disengaged from the backplane, and then
carefully slide the PEM out of the chassis.
6. Remove the two M4 Phillips–head screws installed in the power taps located
on the left and right side of the PEM wiring board. Also remove the two split
cable bushings from the PEM faceplate if they are installed.

8820-A2-GZ45-20

October 2004

3

Installing the Replacement Power Entry Module in the 8820 BAC
Procedure
1. Apply the supplied compression–type ring tongue terminals to the #8 AWG
power wires. Use the Molex Magna Crimp Hand Tool (Part No. MCT–8200).
2. Fasten the #8 AWG wires, with their ring tongue terminals properly installed, to
the power taps using the M4 Phillips-head screws.
— Connect the negative wire to the power tap on the right (48V NEG is
printed on the front of the PEM’s faceplate).
— Connect the return or positive wire to the power tap on the left
(48V RTN is printed on the front of the faceplate).
Tighten the M4 screws securely to the power taps while keeping the ring
tongue terminals and their wires dressed parallel to the board and
perpendicular to the faceplate.
3. Feed and dress the power wires through the notched holes at the top of the
PEM’s faceplate.
4. Slightly spread open the split cable bushings and slip them over each wire and
into the holes at the top of the faceplate. Press on the cable bushing to snap it
into the faceplate.
5. Slide the PEM into the chassis using the nylon card guides.
6. Secure the PEM to the chassis using the mounting screws removed from the
PEM.

Warranty, Sales, Service, and Training Information
Contact your local sales representative, service representative, or distributor
directly for any help needed. For additional information concerning warranty, sales,
service, repair, installation, documentation, training, distributor locations, or
Paradyne worldwide office locations, use one of the following methods:
„

Internet: Visit the Paradyne World Wide Web site at www.paradyne.com.
(Be sure to register your warranty at www.paradyne.com/warranty.)

„

Telephone: Call our automated system to receive current information by fax
or to speak with a company representative.
— Within the U.S.A., call 1–800–870–2221
— Outside the U.S.A., call 1–727–530–2340



.

*8820-A2-GZ45-20*

Copyright © 2004 Paradyne Corporation. Printed in U.S.A.

4

October 2004

8820-A2-GZ45-20



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 4
Page Mode                       : UseOutlines
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:a06a1ec3-15c3-4242-a57c-1854048ff3dc
Producer                        : Acrobat Distiller 6.0 (Windows)
Keywords                        : Power Entry Module, PEM, 8820-S2-903, 8820-S1-906 Broadband Loop Carrier blc BLC
Create Date                     : 2000:02:22 21:17:54Z
Creator Tool                    : FrameMaker 7.0
Modify Date                     : 2005:01:06 06:34:13-05:00
Metadata Date                   : 2005:01:06 06:34:13-05:00
Document ID                     : uuid:234a0481-3fc7-41c2-b613-4e318a32c1d5
Format                          : application/pdf
Creator                         : Paradyne Corporation
Description                     : Power Entry Module for the 8820 Broadband Access Concentrator, Models 8820-S2-903 and 8820-S1-906
Title                           : Replacement DC Power Entry Module for the 8820 Broadband Access Concentrator Models 8820-S2-903 and 8820-S1-906 Installation Instructions
Author                          : Paradyne Corporation
Subject                         : Power Entry Module for the 8820 Broadband Access Concentrator, Models 8820-S2-903 and 8820-S1-906
EXIF Metadata provided by EXIF.tools

Navigation menu