Parente Fireworks Srl FIREMASTER4KT Firemaster IV Base Station User Manual 7

Parente Fireworks Srl Firemaster IV Base Station 7

Users Manual IX

Download: Parente Fireworks Srl FIREMASTER4KT Firemaster IV Base Station User Manual 7
Mirror Download [FCC.gov]Parente Fireworks Srl FIREMASTER4KT Firemaster IV Base Station User Manual 7
Document ID1064570
Application IDi2UHDemryLSWDvKVhsLVMA==
Document DescriptionUsers Manual IX
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize5.61kB (70076 bits)
Date Submitted2009-02-04 00:00:00
Date Available2009-02-04 00:00:00
Creation Date2008-12-28 16:40:16
Producing SoftwareAcrobat Distiller 7.0 (Windows)
Document Lastmod2009-01-15 14:55:15
Document Title7
Document CreatorAcrobat PDFMaker 7.0 for Word
Document Author: Lucio G. Cizza

FIREMASTER IV "Millennium Three" radio shooting System
User’s manual
7.0 TECHNICAL SPECIFICATIONS
7.1 TX5000 BASE UNIT - TECHNICAL SPECIFICATIONS
™
™
™
™
™
™
™
™
™
™
™
™
™
™
™
™
™
™
™
™
™
CODE TRANSMISSION SYSTEM: bi-directional RADIO link
RECEIVER: single-conversion super heterodyne, quartz-controlled, FM
RECEIVING SENSITIVITY: 0.15µV/m at 20db S/N
RECEIVING FREQUENCY: 40.665MHz
TRANSMITTER: 4-stage, FM, quartz-controlled.
TRANSMISSION FREQUENCY: 40.685MHz ±12kHz
TRANSMISSION POWER: in conformity with FCC Cfr. 47 part.15 sub B
SAFETY CODING: 36-bit binary sequence with fire code protection,
user's code, parity.
DISPLAY (for parameters and sequences displaying): GRAPHIC LCD
320x240 pixels (1/4VGA) with LED backlight.
R.F. CARRIER INDICATION: LED indicator on the front-panel
RECEIVED SIGNAL INDICATOR: direct reading in dBµV
SYSTEM AUTONOMY WITH FULLY-CHARGED BATTERIES: more
than 10 hours
SAFETY KEY SWITCH: OFF/CHARGE - SAFE/TEST - FIRE
KEYBOARD: membrane type, splash proof, 35 keys
MICROPROCESSOR: 16-bit – 20MHz - H8S family
SHOW PROGRAM AND CODES STORAGE: E2PROM
MAIN PROGRAM STORAGE: FLASH EPROM
MAIN FIRE SEQUENCES: 1 to 24.000 sequential, random or with autoincrement
MAXIMUM NUMBER OF REMOTE UNITS IN A SINGLE SYSTEM: 255
MAXIMUM NUMBER OF INDEPENDENT LINES: 6120
STANDARD INTERFACES: RS-232, RS-485, SMPTE, MIDI and
ANALOG I/O for the pyromusical synchronization with AUDIO tones
7.2 RX48 TWIN REMOTE UNITS TECHNICAL SPECIFICATIONS
™
™
™
™
™
™
™
™
™
™
™
™
™
™
™
™
™
™
CODE TRANSMISSION SYSTEM: bi-directional RADIO link
RECEIVER: single-conversion super heterodyne, quartz-controlled, FM
RECEIVING SENSITIVITY: 0.15µV/m at 20db S/N
RECEIVING FREQUENCY: 40.685MHz
TRANSMITTER: 4-stage, FM, quartz-controlled.
TRANSMISSION FREQUENCY: 40.665MHz ±12kHz
TRANSMISSION POWER: in conformity with FCC Cfr. 47 part.15 sub B
SAFETY CODING: 36-bit binary sequence with fire code protection,
user's code, parity.
R.F. CARRIER INDICATION: LED indicator on the front-panel
RECEIVED SIGNAL INDICATOR: direct reading in dBµV
MEAN DECODING TIME FOR A VALID FIRE COMMMAND: 0,1s
FIRE PULSE DURATION: 0.2s
CODES AND SEQUENCES PROGRAMMING: by RADIO link from the
Base Unit or with RS-232 serial port
MAXIMUM NUMBER OF AVAILABLE SEQUENCES: 9999
LINES AND SQUIB TEST: automatic measure of the total resistance,
direct reading in ohm
TEST CURRENT FOR SQUIBS: 1mA
FIRING LINES: 48 independent (managed as TWO independent 24-line
units). Quick-connecting terminals, metal-plated.
LINE DRIVERS: solid-state with MOS-FET transistors.
96
FIREMASTER IV "Millennium Three" radio shooting System
User’s manual
7.3 BPK-48A BATTERY PACK TECHNICAL SPECIFICATIONS
™ SYSTEM BATTERY: sealed accumulator, lead-acid type with solid gel
electrolyte - 12V 5.7Ah
™ FIRING LINES BATTERIES: 2 sealed accumulators lead-acid type with
solid gel electrolyte - 12V 1.2Ah for a total firing voltage of 24V
™ LINE CURRENT: 1A continuous, up to 8A peak
™ CONTROL SYSTEM: with dedicated microprocessor
™ CHARGE SISTEM: from mains (110/240Va.c. 50-60Hz), internal power
supply, dedicated microprocessor
™ FUNCTIONS: automatic sequential test of all batteries, automatic
charge with control, automatic shut-off.
™ MEASUREMENTS: open-circuit voltage, voltage under load, variation
percentage, maximum charging current, end-of-charge current.
97

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Tagged PDF                      : Yes
XMP Toolkit                     : 3.1-702
Producer                        : Acrobat Distiller 7.0 (Windows)
Company                         : STEROGLASS s.r.l.
Source Modified                 : D:20081228154003
Create Date                     : 2008:12:28 16:40:16+01:00
Creator Tool                    : Acrobat PDFMaker 7.0 for Word
Modify Date                     : 2009:01:15 14:55:15+01:00
Metadata Date                   : 2009:01:15 14:55:15+01:00
Document ID                     : uuid:c8b15886-f1e0-4bbe-981f-8f48eedb6f41
Instance ID                     : uuid:c9d22e1e-05f8-484d-99f1-c2f64a344bab
Version ID                      : 11
Format                          : application/pdf
Title                           : 7
Creator                         : Lucio G. Cizza
Subject                         : 
Headline                        : 
Page Count                      : 2
Page Layout                     : OneColumn
Author                          : Lucio G. Cizza
EXIF Metadata provided by EXIF.tools
FCC ID Filing: SLO-FIREMASTER4KT

Navigation menu