Parente Fireworks Srl FIREMASTER4KT Firemaster IV Base Station User Manual SISTEMA FIREMASTER III

Parente Fireworks Srl Firemaster IV Base Station SISTEMA FIREMASTER III

Users Manual XI

Download: Parente Fireworks Srl FIREMASTER4KT Firemaster IV Base Station User Manual SISTEMA FIREMASTER III
Mirror Download [FCC.gov]Parente Fireworks Srl FIREMASTER4KT Firemaster IV Base Station User Manual SISTEMA FIREMASTER III
Document ID1064572
Application IDi2UHDemryLSWDvKVhsLVMA==
Document DescriptionUsers Manual XI
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize15.52kB (194007 bits)
Date Submitted2009-02-04 00:00:00
Date Available2009-02-04 00:00:00
Creation Date2008-12-28 18:04:06
Producing SoftwareAcrobat Distiller 7.0 (Windows)
Document Lastmod2009-01-15 15:38:44
Document TitleSISTEMA FIREMASTER III
Document CreatorAcrobat PDFMaker 7.0 for Word
Document Author: Lucio G. Cizza

System FIREMASTER IV "Millennium Three"
User’s Manual
WARNINGS AND GENERAL
SAFETY RULES
The following rules, suggestions and limitations, should be
carefully followed, both to comply with the most common
safety provisions and to avoid severe and permanent damages
to the FIREMASTER SYSTEM, still obtaining the best
performance.
Use of the FIREMASTER SYSTEM and its ancillary units, is
strictly reserved to pyrotechnic professionals, duly authorized to
fireworks use, following the law provisions of each respective Country.
U# Don’t modify or try to adjust in any way the internal circuitry.
U, 
Don’t store the units in excessively damp or dusty places
nor on unstable surfaces.
U¼
Avoid any water spray on the unit’s front panel. The units ARE
NOT COMPLETELY WATERPROOF! Dry immediately any part
subject to accidental fresh water spray or rain shower. Disconnect and
put aside any unit accidentally sprayed with SEA WATER: these units
must have immediate service in order to clean completely the internal
parts. If an immediate technical service is not possible, try to remove the
salt water using DISTILLED WATER.
UNever clean the front-panels
using solvents, alcohol, acids or bases.
Always wipe gently the surfaces using a soft cloth with neutral and nofoam detergent. Avoid scratching the painted surfaces!
During the show execution, protect your units from the
incandescent fallout closing the protection covers on the panels.
UAvoid as long as possible, to place your units directly on the ground
(mainly if it is wet, muddy or frozen). The units should be always raised
from the ground by at least 50cm – one meter using non-flammable
supports: cardboard, plastic or wood boxes must be avoided!
Ua
Avoid any contact between different units, both directly and by
means of other external metallic parts or surfaces. Avoid in general any
contact between different working units.
UÃÃIt
is NOT suggested to operate the System when the
ambient temperature is OVER 45°C o BELOW -15°C.
System FIREMASTER IV "Millennium Three"
User’s Manual
LÃÃThe
units must be stored in dry places at temperatures
between 5°C and 30°C (maximum limits).
U¥ Avoid overcharging the internal batteries exceeding the prefixed
charging time. 12 hours are enough for a complete re-charge when the
batteries are in good conditions.
LÅ
Always switch OFF all the units before store them in the
deposit.
L Immediately replace all failed batteries or suspected to be detective
(the price of a single battery doesn’t worth a compromised show!)
C Discard the failed batteries in strict accordance with the recycling
and disposal rules existing for this special material.
Should any unit emit unusual smell or smoke, switch it OFF
immediately and remove the internal batteries.
UaAvoid any accidental contact between the metallic parts of the
unit and other external circuits or metallic structures.
Don’t operate the units near or inside deposits of flammable
material, explosives or devices sensible to electromagnetic fields.
Don’t store or recharge the units inside deposits of explosives,
flammables or inside restricted areas. Don’t switch ON the units in
presence of high concentrations of combustible dust or solvent vapors.
Ua
Never connect your units to other instruments not otherwise
specified as ORIGINAL FIREMASTER ACCESSORY or expressly
declared compatible by the producer.
Ua
Don’t connect or dis-connect the electrical squibs while the
units are switched ON. Always switch OFF your units before
proceeding with the squib connection.
Don’t use testers, ohmmeters or circuit checkers to test the line
continuity when the wires are already connected to the unit’s terminals!
Always perform any measurement on the squib while it is
DISCONNECTED from the unit!
UaImperatively
do NOT use external voltage sources trying to
increase the voltage or the current of the System.
System FIREMASTER IV "Millennium Three"
User’s Manual
Ly
Clear the firing site from the personnel when, with mortars
loaded and squibs connected, the units are switched ON. Clear the site
as well during the whole programming and test steps on the lines and
sequences. Always perform any programming and test operation
maintaining the maximum safety condition for all the operators.
L³Remove the safety key from the units during all the operations
involving the squib connection, mortar loading, etc. Avoid any unauthorized use of the System by personnel not qualified or in the wrong
moment.
UªImperatively DO NOT USE cellular phones, cordless, walkietalkies, transmitters, brush motors, high-energy electrical devices,
industrial lamps with power reactors, etc. in proximity of the
FIREMASTER SYSTEM and its ancillary units while operative (both in
SAFE and FIRE mode) and mainly when the squibs are already
connected to the system.
UaStrictly avoid any electrical contact between the squib lines and
any other external circuit or metallic part. Also avoid any contact
between the squib wires and metallic parts of the same unit. To each
connector must be present only the insulated wires of a single firing line
completely free from any other contact.
Ua
Carefully insulate all the squib terminal junctions and avoid any
electrical leakage (wet junctions or lines) between wires of different lines
or with respect the ground or metallic surfaces.
L NEVER use the FIREMASTER SYSTEM and its peripheral units
for any other purpose but the control and firing of PYROTECHNIC
SHOWS.
FAILING TO OBSERVE ONE OR MORE OF THE ABOVE
WARNINGS, COULD LEAD TO SEVERE FAILURES, DAMAGES
TO PEOPLE AND MATERIAL, COMPLETELY OUTSIDE OF THE
PRODUCER RESPONSIBILITY, OTHER THAN PERMANENT
DAMAGES AND THE IMMEDIATE WARRANTY VOIDING!
System FIREMASTER IV "Millennium Three"
User’s Manual
PRELIMINARY OPERATIONS FOR
THE FIRST INSTALLATION
1) Lift the units from the shipping packages (box, container, etc.)
2) Check carefully for any dispersed accessory (cables, antenna,
software CD, etc.) before discarding the packing material.
3) Proceed with an accurate visual inspection of the units in order to
discover possible damages, breaks, tampering, etc.
4) The following items should be checked in particular:
• Enclosure, top cover and fasteners
• Connectors
• Front panels
5) Shake each unit in order to discover noises due to internal parts
loosening.
6) All contacts and other exposed metal parts should not present
traces of corrosion or oxidation
7) No traces of liquid spillage (batteries) must be present.
Should any of the above problems be present, DON’T OPERATE THE
INSTRUMENT but contact immediately the Service Center!
The units of the FIREMASTER series are usually supplied
batteries ALREADY INSTALLED AND READY-TO-USE:
happen however as, due to a long storage period before
installation, the batteries become partially discharged.
In this case the unit SHOULD BE NOT INSTALLED but a
COMPLETE CHARGE of the batteries must be performed.
with the
it could
the first
previous
NOTE: The batteries are subject to a natural auto-discharge during the
storage periods. The discharge rate is function of the battery residual life
and of the ambient temperature (higher the temperature, faster the autodischarge).
In particular climatic conditions and for very prolonged inactivity
periods (over 60 days), it may happen as the batteries fall BELOW THE
MINIMUM ALLOWED LEVEL FOR A REGULAR RE-CHARGE. In
this case the batteries must be considered as PERMANENTLY
DAMAGED. A single charging cycle can be still attempted. If this last
attempt shouldn’t succeed, DO NOT INSIST AGAIN, but REPLACE
THE DAMAGED BATTERIES WITH NEW ONES.
Contact the Service Centre to obtain details about the batteries
replacement.
We recall here the RECYCLING RULES for the battery
disposal: avoid at any extent to discard the failed batteries along with
the normal urban waste, but always ask to a specialized collecting
centre for this type of special, polluting waste!
System FIREMASTER IV "Millennium Three"
User’s Manual
PRELIMINARY OPERATIONS FOR
THE STARTUP
1) Before switching ON any unit of the FIREMASTER series,
remember to connect the antenna (only for the units fitted with
this component) reading carefully the User’s manual.
2) The continuous use of a FIREMASTER unit without the antenna
properly installed, could lead to severe damage of the internal
circuitry!
3) The unit will be switched ON using the safety key or the general
power switch.
4) Check immediately as the unit behavior is the correct one
described in the User’s manual.
5) Should any irregular behavior be noticed or emission of smoke or
sparks, SWITCH OFF THE UNIT IMMEDIATELY and DO
NOT ATTEMPT A SECOND TIME! ASK IMMEDIATELY
THE SERVICE CENTRE!
6) The FIREMASTER units don’t have controls, adjustments or
commands, nor internal, nor external, to be tuned by the User. In
case of failure or apparent malfunction, DO NOT ATTEMPT
TO OPEN THE UNITS AND MANIPULATE THE
INTERNAL CIRCUITRY! (This operation, if not duly
authorized by the Service Centre, WILL IMMEDIATELY VOID
THE WARRANTY!)
System FIREMASTER IV "Millennium Three"
User’s Manual
CERTIFICATIONS
The FIREMASTER IV "Millennium Three" SYSTEM is provided with the
mandatory CE marking and fulfills all the rules and product directives as
required by the Law. In particular the FIREMASTER System has been tested by
a "Notified Body" (EUROFINS 0681).
The FIREMASTER IV "Millennium Three" SYSTEM is COMPLIANT
with the following directives:
ELECTROMAGNETIC COMPATIBILITY: EN 301 489- 3 V1.4.1 (2002) ,
EN 301 489- 1 V1.6.1 (2005), EN 55014-1 (2001) + A1 (2001) + A2 (2002) +
EN 55014-2 (1997) + A1 (2001) - Rif. R&TTE
RADIO SECTION: EN 300 220-1 V2.1.1 (04-2006), EN 300 220-2 V2.1.2
(06-2007), EN 50371 (03-2002)- Ref. R&TTE
ELECTRIC SAFETY: EN 60950-1 (2001) + EN 60950-1/A11 : 2004 - Ref.
R&TTE
FCC CERTIFICATION: CFR47 Part.15 sub B. Par.15.107 and 15.109, Part
15 sub C Par. 15.231
FCC I.D.:
SLO-FIREMASTER4KR
(RX48)
FCC I.D.:
SLO-FIREMASTER4KT
(TX5000)
This device complies with Part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) this device may not cause
harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
System FIREMASTER IV "Millennium Three"
User’s Manual
DECLARATION OF CONFORMITY
Hereby
PARENTE FIREWORKS s.r.l
Via Oberdan, 107
45037 MELARA (RO) -ITALY
declares that this
"SYSTEM FIREMASTER IV “Millennium Three”
composed by the following sub-assemblies:
BASE UNIT TX5000
REMOTE UNIT RX48
EMERGENCY BATTERY PACK BPK 48-A
Is in compliance with the essential requirements
and other relevant provisions of Directive
1999/5/EC
WARNINGS
Changes or modifications not expressly approved by the party responsible
for compliance, could void the user's authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
System FIREMASTER IV "Millennium Three"
User’s Manual
WARRANTY
PARENTE FIREWORKS s.r.l
Via Oberdan, 107
45037 MELARA (RO) -ITALY
Tel. ++39-(0)425-89035
Fax ++39-(0)425-89640
www.parente.it
www.firemasterplus.com
info@parente.it
service@firemasterplus.com
Manufacturer of the SYSTEM FIREMASTER IV "Millennium Three" and its
accessories, grants all Units free from manufacturing defects for a period of 12
months from the purchasing date.
All Units requiring service within the warranty period, must be sent back to
PARENTE FIREWORKS - ITALIA or to an authorized laboratory at Customer's
charge.
Before sending any Unit or part for servicing under warranty, make sure all
procedures described in the present manual have been carefully followed..
ALWAYS CONTACT IN ADVANCE A PARENTE FIREWORKS
REPRESENTATIVE TO OBTAIN A WRITTEN AUTHORIZATION FOR
THE SERVICE DETAILS.
When the Units are sent back for servicing, please send also a short description of
failures and problems encountered as well as a description of the ambient and
operating conditions existing when the problem occurred.
We recall here as ALL BATTERIES are EXCLUDED from the present
warranty.
System FIREMASTER IV "Millennium Three"
User’s Manual
SERVICE CENTRE FOR ASSISTANCE
For any necessity of technical service (under warranty or not),
information about the instruments use, technical support for the
FIREMASTER series equipments, please contact:
SERVICE CENTRE FOR ASSISTANCE TO
THE FIREMASTER SYSTEM AND
RELATED ACCESSORIES
ART –CAB di Alfredo Coltro
“Parente Fireworks” Service Centre for the
FIREMASTER SYSTEM and related accessories
ART-CAB
Via Garibaldi, 15 - 22078 Carbonate (CO) - ITALY
P.IVA 01420480137
Tel. - Fax: +39 - 0331 - 831330
E-MAIL: lucizza@tin.it
artcab@coltro-alfredo.191.it
service@firemasterplus.com
System FIREMASTER IV "Millennium Three"
User’s Manual
REPAIR CONDITIONS
ART-CAB, Authorized Service Centre Parente Fireworks, provides
all type of technical service for the Firemaster System units,
both under warranty or not, except for any damage due to fraud
or negligence.
Courtesy Units
Should the repair time extend over the reasonable limits, it will
be possible to supply (when available) the Customer with a
courtesy unit, following a specific request and against payment
of a money caution. The caution will be returned upon return of
the unit in the original conditions.
Repair advancement
To obtain information about the repair advancement of your
Firemaster Unit, please contact directly the Service Centre at:
+39-0331-831330.
Note: before any call to the Service Centre, it is suggested to
obtain the serial number of the unit and your User’s Code. Both
data are available on the label placed on the unit side.
Service outside warranty
The repair of units no longer covered by warranty, is subject to
special conditions. Please check in advance with the Service
Centre the conditions (rates, modes and times).
Service under warranty
The warranty period is 12 months* both for the main units and
the accessories, with exception of the batteries of FIRST
INSTALLATION having a warranty period of 6 months*.
Repair warranty
In case of iteration of the same failure after a repair, the Parente
Fireworks Authorized Service Centre, offers for all repaired
units, a general warranty of 3 months. The warranty is not in
addition with eventual other existing warranties
* Excepted any different provision of the law.
System FIREMASTER IV "Millennium Three"
User’s Manual
GENERAL SALES CONDITIONS
• IVA (tax) not included.
• Shipment with our forwarder and shipment costs at user’s charge (otherwise
following specific directives).
• Package costs at User’s charge.
• Payment: 30% in advance with the order and the remaining upon goods receipt.
• The company reserves the faculty to vary at any moment the dimensions and
shape of its products without prior notice and to make any modifications or
improvements following its unobjectionable decision.
TECHNICAL SERVICE OF THE FIREMASTER PRODUCTS - GENERAL CONDITIONS
• The warranty period is 12 months from the goods receipt date.
• The warranty doesn’t cover the consumables, the rechargeable batteries and, in
general, any component subject to wear, the failures due to shocks, drop, misuse
or abuse, accidental causes or failures due to the transportation.
If the warranty seal is removed or tampered, the warranty is immediately void.
• The repair of the failed units will be performed following the type of problem
declared by the User.
• Any repair under warranty must be expressly requested.
• The pro-forma invoice must be requested expressly.
• Payment must be made BEFORE the unit is sent back.
REPAIR UNDER WARRANTY
• The repairs under warranty are always intended in our laboratories upon written
authorization
• For any repair under warranty, it is requested copy of the purchase invoice or
shipment document allowing to check the purchase period is within the warranty
limits.
• Should the product sent for repair result in perfect conditions, the Customer will
be in any case charged by € 25.
REPAIR OUTSIDE WARRANTY
• For any repair not covered by warranty performed in our laboratories and with
written authorization, the shipment costs are at User’s charge.
• With limitation to the replaced parts during the repair, the warranty of the repair
service is 12 months from the unit collect.
• Should the product sent for repair result in perfect conditions, the Customer will
be in any case charged by € 25.
REPAIR AT PURCHASER DOOR
• In case of repair directly to the purchaser’s address, it will be necessary a written request
with full indications of the user’s data, type of instrument and nature of failure.
• The cost for the transfer of a specialized technician is related to the urgency of
the service requested.
• If the unit to be serviced should be still covered by warranty, only the repair cost
will be not charged.
• The service time will be calculated from the departure of the technician from the
Service Centre until he will be back. The return time will be evaluated on the basis
of the time spent the first time.
SPARE PARTS AND CONSUMABLES
• Orders must be sent by letter, mail, e-mail or FAX specifying the part type, the
client data, the shipment conditions and the fiscal data for the invoice.
• The delivery time may vary depending on the availability of the requested item.
• It is NOT allowed to send back any spare part.
• Payment will be always at goods receipt, excepted special agreements.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Tagged PDF                      : Yes
XMP Toolkit                     : 3.1-702
Producer                        : Acrobat Distiller 7.0 (Windows)
Company                         : STEROGLASS s.r.l.
Source Modified                 : D:20081228170233
Create Date                     : 2008:12:28 18:04:06+01:00
Creator Tool                    : Acrobat PDFMaker 7.0 for Word
Modify Date                     : 2009:01:15 15:38:44+01:00
Metadata Date                   : 2009:01:15 15:38:44+01:00
Document ID                     : uuid:18a258ff-296a-4ccb-8187-53d7e7bc4de0
Instance ID                     : uuid:ae557356-8f82-478c-8529-c1e1e3c14778
Version ID                      : 13
Format                          : application/pdf
Title                           : SISTEMA FIREMASTER III
Creator                         : Lucio G. Cizza
Subject                         : 
Headline                        : 
Page Count                      : 11
Page Layout                     : OneColumn
Author                          : Lucio G. Cizza
EXIF Metadata provided by EXIF.tools
FCC ID Filing: SLO-FIREMASTER4KT

Navigation menu