Parker Hannifin MSLINK0006 200 Series Radio Module User Manual Exhibit D Users Manual per 2 1033 b3

Lord Corporation 200 Series Radio Module Exhibit D Users Manual per 2 1033 b3

Exhibit D Users Manual per 2 1033 b3

LORD Corporation 9/26/2017 Prepared by J. Dunklee
200 Series Radio Module Integration Guide
1. Overview
The 200 Series Radio Module is an OEM device used to acquire data from LORD Corporation wireless sensing
devices. It is designed to be embedded in other products to provide radio communication and data pass-
through capabilities in a modular format. It is designed to be used with LORD data acquisition software or
user software developed using the LORD MSCL code library.
The module includes an integrated microcontroller/radio transceiver that communicates to LORD devices in
the 2.4 GHz band. There are two radio transmission protocols that are available on the radio module the
standard 802.15.4 protocol (LXRS) and a LORD proprietary protocol (LXRS+). The modes are selectable in the
LORD software. Both are capable of lossless transmission of continuous, burst, and other sampling modes,
depending on the node capabilities. The increased radio transmission rate of the LXRS+ protocol results in
faster network throughput, and the ability to handle larger data packets. However, because of the increased
packet size, the packet error rate will likely increase (reducing RF sensitivity) and effectively reducing the RF
range.
2. Integration
The radio module requires a PCB carrier board for proper integration. This board can be designed by LORD,
or by an OEM customer with the information provided in this document. The carrier board provides power
(+5 Vdc +/- 2%, 50mA) to the radio module, as well as the serial and input/output interface to connect the
microcontroller to the larger communication system. The microcontroller code required to control the radio
module is proprietary and is developed at LORD.
The following section describes physical layout and pin configuration of the module. The module is 0.98” x
0.53”. It has an internal antenna on one end of the board. The interface to the carrier board is through solder
pads around the three other sides of the board. For exact layout dimension of these pads, contact LORD
Technical Support for an engineering file.
The radio module is an OEM circuit board intended to be housed in an enclosure of the type suitable for the
final product. It has no environmental protection by itself. Operating temperature range is -40 to +85 °C.
LORD Corporation 9/26/2017 Prepared by J. Dunklee
Physical Interface
Internal antenna location
Carrier board solder pads
(around board edge)
Dimensions in inches
LORD Corporation 9/26/2017 Prepared by J. Dunklee
Pin Interface
Radio Module
pin number
Signal name
Description
1
DGND
Digital ground
2
EFR32MG RESET
Microcontroller reset
3
PF7
Microcontroller general purpose I/O
4
PF6
Microcontroller general purpose I/O
5
PF5
Microcontroller general purpose I/O
6
PF4
Microcontroller general purpose I/O
7
PF3
Microcontroller general purpose I/O
8
DBG_SWO
Serial Wire Debug trace data output
9
DBG_SWDIO
Serial Wire Debug data in/out
10
DBG_SWCLK
Serial Wire Debug clock
11
PC11
Microcontroller general purpose I/O
12
PC10
Microcontroller general purpose I/O
13
PC9
Microcontroller general purpose I/O
14
PC8
Microcontroller general purpose I/O
15
PC7
Microcontroller general purpose I/O
16
PC6
Microcontroller general purpose I/O
17
DGND
Digital ground
18
PD10
Microcontroller general purpose I/O
19
PD11
Microcontroller general purpose I/O
20
PD12
Microcontroller general purpose I/O
21
PD13
Microcontroller general purpose I/O
22
PD14
Microcontroller general purpose I/O
23
PD15
Microcontroller general purpose I/O
24
DGND
Digital ground
25
VCC
Module power input +5V dc
26
PB15
Microcontroller general purpose I/O
27
PB13
Microcontroller general purpose I/O
28
PB12
Microcontroller general purpose I/O
29
PB11
Microcontroller general purpose I/O
30
PA5
Microcontroller general purpose I/O
31
PA4
Microcontroller general purpose I/O
32
LED_RED
Status LED red
33
LED_BLUE
Status LED blue
34
LED_GREEN
Status LED green
35
PA0
Microcontroller general purpose I/O
36
DGND
Digital ground
LORD Corporation 9/26/2017 Prepared by J. Dunklee
3. Regulatory
a. Radio modules must be labeled with the corresponding FCC/IC ID number. Product assemblies
with radio modules in them must be labeled “Contains 200 Series Radio Module” followed by the
FCC/IC ID.
b. The following notice applies to the radio module and must also appear in its entirety in the final
product user manual. In addition, based on the antennas and power parameters specified for this
device, it must be operated at least 2.16 cm from the operator to ensure RF levels do no exceed
what is considered healthy for human exposure.

Navigation menu