Paxton Access 162739 OEM Plastic Reader Keypad / Mace Security Standalone Plastic Reader & Keypad User Manual INSTRUCTION OEM plastic reader keypad
Paxton Access Ltd OEM Plastic Reader Keypad / Mace Security Standalone Plastic Reader & Keypad INSTRUCTION OEM plastic reader keypad
Contents
- 1. Paxton User Manual
- 2. Mace Security User Manual
Paxton User Manual
09/23/2009 Ins-30012-US OEM plastic reader keypad Technical Support 1.800.672.PAXT Technical help is available: support@paxton-access.com Monday - Friday from 12:00 AM - 5:00 PM (PST) Saturday from 1:00 AM - 5:00 AM (PST) Documentation on all Paxton Access products can be found on our web site - http://www.paxton-access.com/ Suitability Wet environments Mounted on metal surface Security sensitive doors Readers mounted together 12 inches between readers Fitting Exit button (push to make) Grey Black 9-15V DC +12V DC White (fuse rating 1A) 0V 12V DC release current rating must be less than 1A. * The diode current rating must be equal to or greater than the current in the release User cards are NOT supplied with this unit. Please supply your own user cards. Page Please read the following notes before installing Electrical shock from voltages used in this system can cause injury or death. Prior to making any electrical connections, or performing maintenance and repair, ensure power is removed. Mains electrical connections should be made only by qualified personel in accordance with local regulation. Safety goggles should be worn while using power tools. Fitting the keypad Step 1: Carefully mark out the mounting holes for the keypad and the hole of the cable feed. Step 2: Drill the marked holes for the mounting points and the cable feed. When drilling the holes, ensure that you are aware of any hidden cables or pipes. Once the holes have been drilled, fit the supplied wall plugs and feed the cable through the cable feed hole before securing the reader to the wall using the screws supplied. Step 3: Fit the keypad to the mounting plate and secure using the screw provided. FCC Compliance This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Page Setting The Master Code The first time the keypad is turned on the RED and GREEN LEDs flash alternately. This indicates a 6 digit Master Code must now be entered. »The Master Code allows access to the Programming Menu. To set the Master Code, do the following: Press Press Enter 6 digit Master Code The factory User Code is now set to 7890 Press Enter 6 digit Master Code Press to exit programming mode see for programming options see for adding proximity tokens NOTE The Master Code must not contain a User Code (for example 123456 as a Master Code and 2345 as a User Code would cause the door to open before the Master Code had been entered. Changing the entry code Enter 6 digit Master Code The RED and GREEN LEDs flash simultaneously indicating reader is in Programming Mode Press and hold for 3 seconds Enter code 4-8 digits Press re-enter code Press = Normal = Master = Delete Press to exit programming mode Changing the door open time Enter 6 digit Master Code The RED and GREEN LEDs flash simultaneously indicating reader is in Programming Mode Press and hold for 3 seconds Press Enter 2 digits from 01 to 60 (default door open time is 07 seconds to exit programming mode Changing the lock type Enter 6 digit Master Code The RED and GREEN LEDs flash simultaneously indicating reader is in Programming Mode Press and hold for 3 seconds { *# = Fail open press = Fail locked Press = default to exit programming mode Page Changing the keypad backlight Enter 6 digit Master Code The RED and GREEN LEDs flash simultaneously indicating reader is in Programming Mode Press and hold for 3 seconds { *# } = On press = Off Setting multiple entry codes (maximum = 120) Press = default to exit programming mode Enter 6 digit Master Code The RED and GREEN LEDs flash simultaneously indicating reader is in Programming Mode Press and hold for 3 seconds { *# } = On press = Off Press to exit programming mode When in Multi User Code mode the (star) key must be pressed after the code is entered for the door to release. = default Setting the keypad sounder Enter 6 digit Master Code The RED and GREEN LEDs flash simultaneously indicating reader is in Programming Mode Press and hold for 3 seconds { *# } = Off press = On Press = default to exit programming mode Setting the exit button mode Enter 6 digit Master Code The RED and GREEN LEDs flash simultaneously indicating reader is in Programming Mode Press and hold for 3 seconds = Normal = Toggle = Disabled (press once to open door) (press once to open, press again to close) (exit button does not open the door) Press = default to exit programming mode Page Setting the keypad for additional security Enter 6 digit Master Code The RED and GREEN LEDs flash simultaneously indicating reader is in Programming Mode { *# } Press and hold for 3 seconds = On press = Off When enabled, the keypad will deactivate for 60 seconds if there are 20 consecutive incorrect numbers entered Press to exit programming mode = default Changing the Master code Enter 6 digit Master Code The RED and GREEN LEDs flash simultaneously indicating reader is in Programming Mode Press and hold for 3 seconds Press Enter new 6 digit Master code Re-enter new 6 digit Master code Press Press to exit programming mode Resetting the keypad (EXCEPT the master code) Enter 6 digit Master Code The RED and GREEN LEDs flash simultaneously indicating reader is in Programming Mode Press and hold for 3 seconds Press and hold for 3 seconds Enter Master code Press Press Once completed, all settings except the Master code will be restored to their default setting to exit programming mode Resetting the keypad (INCLUDING the Master code) Remove power to the keypad Press and hold Creating a master token Re-apply power, still holding 2 Hold for 3 seconds once power is applied Once reset, the keypad will need a new Master code set, as per the programming section The first token must be registered as a Master token. This will be required for the addition of other proximity tokens and also the proximity programming functions. Enter 6 digit Master Code The RED and GREEN LEDs flash simultaneously indicating reader is in Programming Mode Press and hold for 3 seconds Press Press Press Press Present proximity token to the keypad Press Press exits programming mode Page Adding proximity tokens Up to 2000 proximity tokens can be added to the keypad. Each token is allocated to a memory slot on the keypad. A note will need to be made of the memory slot a token is allocated to, a handy table is included in these instructions for this purpose. To add a proximity token to the reader do the following: Present the Master Token The RED and GREEN LEDs flash simultaneously indicating reader is in Programming Mode Enter memory slot number Press Press Re-enter memory slot number Press Present proximity token to the keypad or Press to exit programming mode or Adding proximity plus PIN tokens For additional security, you may wish a user to enter a PIN (personal identification number) as well as present a proximity token, in order to open the door. To configure a token to require PIN entry as well, do the following: Present the Master Token The RED and GREEN LEDs flash simultaneously indicating reader is in Programming Mode Enter memory slot number Press Re-enter memory slot number Press Press Press Re-enter PIN Enter PIN Present proximity token to the keypad Press or Press to exit programming mode or Barring proximity tokens If a proximity token has been lost, or you no longer wish the user to gain entry, the proximity token can easily be removed from the system. To remove a user token, do the following: Present the Master Token The RED and GREEN LEDs flash simultaneously indicating reader is in Programming Mode Enter memory slot number Press Re-enter memory slot number Press Press Press to exit programming mode Page Technical Help Here is the list of topics about this product that receive the most technical support inquiries. We list them here to help you speed up the installation and trouble shooting process. 1. I have connected the keypad correctly. Why doesn’t it open when I enter my code? QQ QQ QQ- Check that there is power to the keypad by setting the keypad backlight to ON, and listening for keypad beeps. If not, check the power supply. Check that the green light flashes when the correct code is entered. If not, the code has not been entered correctly, or may have been incorrectly programmed initially. Check that the lock is capable of operating with a 12V DC power supply. Check the connections. 2. When I enter my code, I hear a click and the unit resets. Why does the release not unlock? QThis can be caused by incorrect wiring of the output wires or the diode. If a DC lock is used, check that a diode Qis connected across the lock so that the band is nearest the +V connection. This fault may blow a fuse in the Qpower supply - check for above before replacing the fuse. 3. The door is always unlocked. Why, and how do I get it to lock again? QIf the green light on the keypad is on constantly, check the type of lock that is fitted. If it is a fail open type, Qit requires power to be applied to its terminals to keep it locked. A fail locked type (more common) requires power Qonly when it is to be kept open. Refer to the programming instructions to set the keypad for the correct lock type. QIf this is set correctly, check all wiring for shorts or bad connections. Check that a diode is fitted to the DC lock Qand is connected correctly. If not, the keypad may be damaged and will have to be replaced. Damaged relay Qcontacts are not covered by product warranty. QIf the green light on the keypad is flashing, switch off the power. Wait for 10 seconds and switch the power Qon again. If the door is locked and the green light is on constantly again, it is likely that the user code is set to Qoperate in toggle mode. If you do not want toggle codes, reset the keypad and enter new codes accordingly. QIf on re-applying power, the keypad’s green light is still flashing, and the door is still open, check the exit button Q(grey) wires. These could be connected to an exit button of the incorrect type, or shorted by faulty wiring, or the Qexit button operation could be set incorrectly. Rectify and re-test. Specifications Features Number of Users Code length Min Max 2,000 4 digits 8 digits 4 digits PIN length Door open time 1 sec 60 sec Silent operation Yes Can be used with fail OPEN locks Yes Can be used with fail CLOSED locks Yes Exit button input Yes Yes Backlight Electrical Voltage Min Max 9V DC 15V DC Current 30 mA 1A Switchable current Environment Operating temperature Waterproof Min Max -20°C (-4°F) 55°C (131°F) Outdoor Use IP67 3 yards Cable length Dimensions Width Height Depth 2 3/4 inch 4 1/2 inch 1 1/4 inch Page Page
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 8 XMP Toolkit : XMP toolkit 2.9.1-14, framework 1.6 About : uuid:4f73bd57-9c3c-441b-b023-34060144fdfc Producer : Adobe PDF Library 7.0 Trapped : False Create Date : 2009:09:23 15:26:09+01:00 Metadata Date : 2009:09:23 15:27:17+01:00 Modify Date : 2009:09:23 15:27:17+01:00 Creator Tool : Adobe InDesign CS2 (4.0.5) Thumbnail Format : JPEG Thumbnail Width : 256 Thumbnail Height : 256 Thumbnail Image : (Binary data 9142 bytes, use -b option to extract) Instance ID : uuid:19541ea0-d750-44b9-b9b6-666617d8794a Rendition Class : proof:pdf Document ID : adobe:docid:indd:c92b4b7d-a820-11de-82a4-e0f2d67172a3 Derived From Instance ID : d1f7b89b-9d1e-11de-933c-8368ebcd2a2a Derived From Document ID : adobe:docid:indd:d53d4e84-8e4a-11de-ba6c-f7ed73c1bd00 Manifest Link Form : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream Manifest Placed X Resolution : 300.00, 300.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 300.00 Manifest Placed Y Resolution : 300.00, 300.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 300.00 Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches Manifest Reference Document ID : adobe:docid:photoshop:bb839163-96cd-11d9-a531-cac364ccc92b, uuid:8e68e80f-29c7-4ef0-97f2-2d95e832cc3e, uuid:CC7C967DC0FEDB11B930C9FD519FB3DD, uuid:CE7C967DC0FEDB11B930C9FD519FB3DD, uuid:9F081A2912FFDB119AA6E0979456848E, uuid:A3081A2912FFDB119AA6E0979456848E, uuid:4109C0F186FFDB11AD68B8286A02C14E, uuid:4309C0F186FFDB11AD68B8286A02C14E, uuid:AABE05C3A8FFDB11AE91D8996E4E718D, uuid:ACBE05C3A8FFDB11AE91D8996E4E718D, uuid:743897CBA081DE11B316DB3521D4CD4D, uuid:5CEB0E0CC100DC11A939A562EBB41FC7, uuid:5EEB0E0CC100DC11A939A562EBB41FC7, uuid:EADAFAE60015DC119CDAD7166E0A6DAD, uuid:AEBE05C3A8FFDB11AE91D8996E4E718D, uuid:43c4b14c-782f-4bed-8331-83bf21b112f5, uuid:6722c454-d37a-422b-8ad0-f4ba503f6fca, uuid:d6ed1665-1fab-43e1-a863-90968cfd01e5, adobe:docid:photoshop:bc9a1007-ecb9-11db-9cf4-dbee6e290e0e Manifest Reference Instance ID : uuid:f933251c-6ace-4030-b88b-49a1e6697456, uuid:ff332616-9279-41c7-aa43-98addab7c961, uuid:ea45a4bb-c283-4e32-a218-124308bda866, uuid:d568f1d8-7035-4448-bb44-f31b704abf3a, uuid:2e387384-3187-4900-8eb6-642373d42595, uuid:8af35faf-f031-4acf-89dc-2166ad0f5d7a, uuid:5d797dc6-eafe-4309-b1e5-8b5c00050517, uuid:b1226573-e20d-4a1e-b694-ec091587d81c, uuid:e4013a42-09b5-4b6d-a71f-1757bd1cb760, uuid:db2f1930-a148-41f3-a1c7-b61fe280aa2d, uuid:166295d1-502f-4b8a-a9c3-e269a77d3874, uuid:bef9bfc9-0b9d-432d-bd38-9a73c996dfca, uuid:890a49a2-9fb0-41c8-ba1d-33f92b6adfab, uuid:11568d0b-3910-4fb8-a0c6-31655e9c21f2, uuid:a88b2af6-b80d-45e3-a327-2faa2c3d6fa0, uuid:b539de36-002a-41a1-8ce6-3f2c699c1c82 Format : application/pdf Title : INSTRUCTION - OEM plastic reader keypad Tagged PDF : Yes Creator : Adobe InDesign CS2 (4.0.5)EXIF Metadata provided by EXIF.tools