Paxton Access 162739 OEM Plastic Reader Keypad / Mace Security Standalone Plastic Reader & Keypad User Manual INSTRUCTION OEM plastic reader keypad

Paxton Access Ltd OEM Plastic Reader Keypad / Mace Security Standalone Plastic Reader & Keypad INSTRUCTION OEM plastic reader keypad

Contents

Paxton User Manual

Download: Paxton Access 162739 OEM Plastic Reader Keypad  / Mace Security Standalone Plastic Reader & Keypad User Manual INSTRUCTION   OEM plastic reader keypad
Mirror Download [FCC.gov]Paxton Access 162739 OEM Plastic Reader Keypad  / Mace Security Standalone Plastic Reader & Keypad User Manual INSTRUCTION   OEM plastic reader keypad
Document ID1174347
Application IDclE6Npsfb4xoZrFY6YLlKQ==
Document DescriptionPaxton User Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize120.87kB (1510814 bits)
Date Submitted2009-09-24 00:00:00
Date Available2009-09-24 00:00:00
Creation Date2009-09-23 15:26:09
Producing SoftwareAdobe PDF Library 7.0
Document Lastmod2009-09-23 15:27:17
Document TitleINSTRUCTION - OEM plastic reader keypad
Document CreatorAdobe InDesign CS2 (4.0.5)

09/23/2009
Ins-30012-US OEM plastic reader keypad
Technical Support
1.800.672.PAXT
Technical help is available:
support@paxton-access.com
Monday - Friday from 12:00 AM - 5:00 PM (PST)
Saturday from 1:00 AM - 5:00 AM (PST)
Documentation on all Paxton Access products can be found on our web site - http://www.paxton-access.com/
Suitability
Wet environments
Mounted on metal surface
Security sensitive doors
Readers mounted together
12 inches
between readers
Fitting
Exit button
(push to make)
Grey
Black
9-15V DC
+12V DC
White
(fuse rating 1A)
0V
12V DC release current rating
must be less than 1A.
* The diode current rating must
be equal to or greater than the
current in the release
User cards are NOT supplied with this unit. Please supply your own user cards.
Page 
Please read the following notes before installing
Electrical shock from voltages used in this system can cause injury or death. Prior to making
any electrical connections, or performing maintenance and repair, ensure power is removed.
Mains electrical connections should be made only by qualified personel in accordance with local
regulation. Safety goggles should be worn while using power tools.
Fitting the keypad
Step 1: Carefully mark out the mounting holes for the keypad and the hole of the cable feed.
Step 2: Drill the marked holes for the mounting points and the cable feed. When drilling the holes, ensure
that you are aware of any hidden cables or pipes. Once the holes have been drilled, fit the supplied wall
plugs and feed the cable through the cable feed hole before securing the reader to the wall using the
screws supplied.
Step 3: Fit the keypad to the mounting plate and secure using the screw provided.
FCC Compliance
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation. Changes or modifications not
expressly approved by the party responsible for compliance could void the user’s authority to operate the
equipment.
Page 
Setting The Master Code
The first time the keypad is turned on the RED and GREEN LEDs flash alternately.
This indicates a 6 digit Master Code must now be entered.
»The Master Code allows access to the Programming Menu.
To set the Master Code, do the following:
Press
Press
Enter 6 digit
Master Code
The factory User Code is now set to 7890
Press
Enter 6 digit
Master Code
Press
to exit
programming
mode
see
for programming options
see
for adding proximity tokens
NOTE
The Master Code must not contain a User Code (for example
123456 as a Master Code and 2345 as a User Code would cause
the door to open before the Master Code had been entered.
Changing the entry code
Enter 6 digit Master Code
The RED and GREEN LEDs flash simultaneously indicating reader is in
Programming Mode
Press and hold
for 3 seconds
Enter code
4-8 digits
Press
re-enter
code
Press
= Normal
= Master
= Delete
Press
to exit
programming
mode
Changing the door open time
Enter 6 digit Master Code
The RED and GREEN LEDs flash simultaneously indicating reader is in
Programming Mode
Press and hold
for 3 seconds
Press
Enter 2 digits from 01 to 60 (default door open time is 07 seconds
to exit
programming
mode
Changing the lock type
Enter 6 digit Master Code
The RED and GREEN LEDs flash simultaneously indicating reader is in
Programming Mode
Press and hold
for 3 seconds
{ *#
= Fail open
press
= Fail locked
Press
= default
to exit
programming
mode
Page 
Changing the keypad backlight
Enter 6 digit Master Code
The RED and GREEN LEDs flash simultaneously indicating reader is in
Programming Mode
Press and hold
for 3 seconds
{ *# }
= On
press
= Off
Setting multiple entry codes
(maximum = 120)
Press
= default
to exit
programming
mode
Enter 6 digit Master Code
The RED and GREEN LEDs flash simultaneously indicating reader is in
Programming Mode
Press and hold
for 3 seconds
{ *# }
= On
press
= Off
Press
to exit
programming
mode
When in Multi User Code mode
the
(star) key must be
pressed after the code is
entered for the door to release.
= default
Setting the keypad sounder
Enter 6 digit Master Code
The RED and GREEN LEDs flash simultaneously indicating reader is in
Programming Mode
Press and hold
for 3 seconds
{ *# }
= Off
press
= On
Press
= default
to exit
programming
mode
Setting the exit button mode
Enter 6 digit Master Code
The RED and GREEN LEDs flash simultaneously indicating reader is in
Programming Mode
Press and hold
for 3 seconds
= Normal
= Toggle
= Disabled
(press once to open door)
(press once to open, press again to close)
(exit button does not open the door)
Press
= default
to exit
programming
mode
Page 
Setting the keypad for
additional security
Enter 6 digit Master Code
The RED and GREEN LEDs flash simultaneously indicating reader is in
Programming Mode
{ *# }
Press and hold
for 3 seconds
= On
press
= Off
When enabled, the keypad will
deactivate for 60 seconds if
there are 20 consecutive
incorrect numbers entered
Press
to exit
programming
mode
= default
Changing the Master code
Enter 6 digit Master Code
The RED and GREEN LEDs flash simultaneously indicating reader is in
Programming Mode
Press and hold
for 3 seconds
Press
Enter new
6 digit
Master code
Re-enter new
6 digit
Master code
Press
Press
to exit
programming
mode
Resetting the keypad
(EXCEPT the master code)
Enter 6 digit Master Code
The RED and GREEN LEDs flash simultaneously indicating reader is in
Programming Mode
Press and hold
for 3 seconds
Press and hold
for 3 seconds
Enter
Master
code
Press
Press
Once completed, all settings
except the Master code will be
restored to their default setting
to exit
programming
mode
Resetting the keypad
(INCLUDING the Master code)
Remove power
to the keypad
Press and
hold
Creating a master token
Re-apply power,
still holding 2
Hold for 3
seconds
once power is
applied
Once reset, the keypad will need
a new Master code set, as per the
programming section
The first token must be registered as a Master token.
This will be required for the addition of other proximity tokens and also the proximity programming functions.
Enter 6 digit Master Code
The RED and GREEN LEDs flash simultaneously indicating reader is in
Programming Mode
Press and hold
for 3 seconds
Press
Press
Press
Press
Present
proximity token
to the keypad
Press
Press
exits
programming
mode
Page 
Adding proximity tokens
Up to 2000 proximity tokens can be added to the keypad. Each token is allocated to a memory slot on the keypad.
A note will need to be made of the memory slot a token is allocated to, a handy table is included in these instructions
for this purpose. To add a proximity token to the reader do the following:
Present the Master Token
The RED and GREEN LEDs flash simultaneously indicating reader is in
Programming Mode
Enter
memory
slot number
Press
Press
Re-enter
memory
slot number
Press
Present proximity
token to
the keypad
or
Press
to exit
programming
mode
or
Adding proximity plus PIN tokens
For additional security, you may wish a user to enter a PIN (personal identification number) as well as present a proximity
token, in order to open the door. To configure a token to require PIN entry as well, do the following:
Present the Master Token
The RED and GREEN LEDs flash simultaneously indicating reader is in
Programming Mode
Enter
memory
slot number
Press
Re-enter
memory
slot number
Press
Press
Press
Re-enter
PIN
Enter PIN
Present proximity
token to
the keypad
Press
or
Press
to exit
programming
mode
or
Barring proximity tokens
If a proximity token has been lost, or you no longer wish the user to gain entry, the proximity token can easily be removed
from the system. To remove a user token, do the following:
Present the Master Token
The RED and GREEN LEDs flash simultaneously indicating reader is in
Programming Mode
Enter
memory
slot number
Press
Re-enter
memory
slot number
Press
Press
Press
to exit
programming
mode
Page 
Technical Help
Here is the list of topics about this product that receive the most technical support inquiries.
We list them here to help you speed up the installation and trouble shooting process.
1. I have connected the keypad correctly. Why doesn’t it open when I enter my code?
QQ
QQ
QQ-
Check that there is power to the keypad by setting the keypad backlight to ON, and listening for keypad beeps.
If not, check the power supply.
Check that the green light flashes when the correct code is entered. If not, the code has not been entered
correctly, or may have been incorrectly programmed initially.
Check that the lock is capable of operating with a 12V DC power supply.
Check the connections.
2. When I enter my code, I hear a click and the unit resets. Why does the release not unlock?
QThis can be caused by incorrect wiring of the output wires or the diode. If a DC lock is used, check that a diode
Qis connected across the lock so that the band is nearest the +V connection. This fault may blow a fuse in the
Qpower supply - check for above before replacing the fuse.
3. The door is always unlocked. Why, and how do I get it to lock again?
QIf the green light on the keypad is on constantly, check the type of lock that is fitted. If it is a fail open type,
Qit requires power to be applied to its terminals to keep it locked. A fail locked type (more common) requires power
Qonly when it is to be kept open. Refer to the programming instructions to set the keypad for the correct lock type.
QIf this is set correctly, check all wiring for shorts or bad connections. Check that a diode is fitted to the DC lock
Qand is connected correctly. If not, the keypad may be damaged and will have to be replaced. Damaged relay
Qcontacts are not covered by product warranty.
QIf the green light on the keypad is flashing, switch off the power. Wait for 10 seconds and switch the power
Qon again. If the door is locked and the green light is on constantly again, it is likely that the user code is set to
Qoperate in toggle mode. If you do not want toggle codes, reset the keypad and enter new codes accordingly.
QIf on re-applying power, the keypad’s green light is still flashing, and the door is still open, check the exit button
Q(grey) wires. These could be connected to an exit button of the incorrect type, or shorted by faulty wiring, or the
Qexit button operation could be set incorrectly. Rectify and re-test.
Specifications
Features
Number of Users
Code length
Min
Max
2,000
4 digits
8 digits
4 digits
PIN length
Door open time
1 sec
60 sec
Silent operation
Yes
Can be used with fail OPEN locks
Yes
Can be used with fail CLOSED locks
Yes
Exit button input
Yes
Yes
Backlight
Electrical
Voltage
Min
Max
9V DC
15V DC
Current
30 mA
1A
Switchable current
Environment
Operating temperature
Waterproof
Min
Max
-20°C (-4°F)
55°C (131°F)
Outdoor Use
IP67
3 yards
Cable length
Dimensions
Width
Height
Depth
2 3/4 inch
4 1/2 inch
1 1/4 inch
Page 
Page 

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 8
XMP Toolkit                     : XMP toolkit 2.9.1-14, framework 1.6
About                           : uuid:4f73bd57-9c3c-441b-b023-34060144fdfc
Producer                        : Adobe PDF Library 7.0
Trapped                         : False
Create Date                     : 2009:09:23 15:26:09+01:00
Metadata Date                   : 2009:09:23 15:27:17+01:00
Modify Date                     : 2009:09:23 15:27:17+01:00
Creator Tool                    : Adobe InDesign CS2 (4.0.5)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 9142 bytes, use -b option to extract)
Instance ID                     : uuid:19541ea0-d750-44b9-b9b6-666617d8794a
Rendition Class                 : proof:pdf
Document ID                     : adobe:docid:indd:c92b4b7d-a820-11de-82a4-e0f2d67172a3
Derived From Instance ID        : d1f7b89b-9d1e-11de-933c-8368ebcd2a2a
Derived From Document ID        : adobe:docid:indd:d53d4e84-8e4a-11de-ba6c-f7ed73c1bd00
Manifest Link Form              : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 300.00, 300.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 300.00
Manifest Placed Y Resolution    : 300.00, 300.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 72.00, 300.00
Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches
Manifest Reference Document ID  : adobe:docid:photoshop:bb839163-96cd-11d9-a531-cac364ccc92b, uuid:8e68e80f-29c7-4ef0-97f2-2d95e832cc3e, uuid:CC7C967DC0FEDB11B930C9FD519FB3DD, uuid:CE7C967DC0FEDB11B930C9FD519FB3DD, uuid:9F081A2912FFDB119AA6E0979456848E, uuid:A3081A2912FFDB119AA6E0979456848E, uuid:4109C0F186FFDB11AD68B8286A02C14E, uuid:4309C0F186FFDB11AD68B8286A02C14E, uuid:AABE05C3A8FFDB11AE91D8996E4E718D, uuid:ACBE05C3A8FFDB11AE91D8996E4E718D, uuid:743897CBA081DE11B316DB3521D4CD4D, uuid:5CEB0E0CC100DC11A939A562EBB41FC7, uuid:5EEB0E0CC100DC11A939A562EBB41FC7, uuid:EADAFAE60015DC119CDAD7166E0A6DAD, uuid:AEBE05C3A8FFDB11AE91D8996E4E718D, uuid:43c4b14c-782f-4bed-8331-83bf21b112f5, uuid:6722c454-d37a-422b-8ad0-f4ba503f6fca, uuid:d6ed1665-1fab-43e1-a863-90968cfd01e5, adobe:docid:photoshop:bc9a1007-ecb9-11db-9cf4-dbee6e290e0e
Manifest Reference Instance ID  : uuid:f933251c-6ace-4030-b88b-49a1e6697456, uuid:ff332616-9279-41c7-aa43-98addab7c961, uuid:ea45a4bb-c283-4e32-a218-124308bda866, uuid:d568f1d8-7035-4448-bb44-f31b704abf3a, uuid:2e387384-3187-4900-8eb6-642373d42595, uuid:8af35faf-f031-4acf-89dc-2166ad0f5d7a, uuid:5d797dc6-eafe-4309-b1e5-8b5c00050517, uuid:b1226573-e20d-4a1e-b694-ec091587d81c, uuid:e4013a42-09b5-4b6d-a71f-1757bd1cb760, uuid:db2f1930-a148-41f3-a1c7-b61fe280aa2d, uuid:166295d1-502f-4b8a-a9c3-e269a77d3874, uuid:bef9bfc9-0b9d-432d-bd38-9a73c996dfca, uuid:890a49a2-9fb0-41c8-ba1d-33f92b6adfab, uuid:11568d0b-3910-4fb8-a0c6-31655e9c21f2, uuid:a88b2af6-b80d-45e3-a327-2faa2c3d6fa0, uuid:b539de36-002a-41a1-8ce6-3f2c699c1c82
Format                          : application/pdf
Title                           : INSTRUCTION - OEM plastic reader keypad
Tagged PDF                      : Yes
Creator                         : Adobe InDesign CS2 (4.0.5)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: USE162739

Navigation menu