Paxton Access 333210 Compact Proximity Reader P38 User Manual INSTRUCTION PROXIMITY P series compact reader

Paxton Access Ltd Compact Proximity Reader P38 INSTRUCTION PROXIMITY P series compact reader

Contents

Installation manual

Download: Paxton Access 333210 Compact Proximity Reader P38 User Manual INSTRUCTION   PROXIMITY P series compact reader
Mirror Download [FCC.gov]Paxton Access 333210 Compact Proximity Reader P38 User Manual INSTRUCTION   PROXIMITY P series compact reader
Document ID3823947
Application IDnwTo7lG2aSD2yKrOBonqkQ==
Document DescriptionInstallation manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize96.96kB (1212005 bits)
Date Submitted2018-04-20 00:00:00
Date Available2018-04-20 00:00:00
Creation Date2011-11-24 16:16:10
Producing SoftwareAdobe PDF Library 9.9
Document Lastmod2018-02-23 15:42:00
Document TitleINSTRUCTION - PROXIMITY P series compact reader
Document CreatorAdobe InDesign CS5 (7.0.4)

24/11/2011
Paxton
Ins-30003 PROXIMITY P series compact reader
Technical Support
01273 811011
Technical help is available:
support@paxton.co.uk
Monday - Friday from 07:00 - 19:00 (GMT)
Saturday from 09:00 - 13:00 (GMT)
Documentation on all Paxton products can be found on our website - http://www.paxton.co.uk/
Suitability
Security-sensitive doors
Wet environments
Mounted on metal surface
Readers mounted together
300 mm
between readers
Quickstart guide
This supplement is a brief guide to installing a P series compact system. Further information is available for
download at: http://www.paxton.co.uk/ or call the communications team on: 01273 811011.
Exit
12V DC power
supply
0V
+12V
0V
Exit button
(push to make)
+12V
0V
P75 Screw connector option
Electric release
12V DC release current rating must be less than 1A.
The unit should be mounted in conjunction with
an electrical backbox to achieve the required
clearance for the connector.
If an adaptor plate (310-750) is fitted, the
mountings on the backbox can also be used.
Indoor use only
Reset - Use one method
1.
2.
3.
4.
+12V DC
0V
Lock 12V
5.
Lock 0V
1.
2.
3.
4.
5.
Exit input
Exit 0V
Power down the unit.
Press and hold the exit button.
Power up the unit. It will give several quick beeps.
Wait for a further beep and then release and press			
the exit button twice more.
The reader will beep 3 times to confirm the reset.
OR
Present Enrolment card.
Present Door open time card twice.
Present Enrolment card.
Present Door open time card twice.
WAIT FOR 5 SECONDS!
Wiring
Fitting
Reader covers
Additional covers are available in black, white, grey, blue and silver. Registered installers can order these free
of charge by logging onto the secure installer extranet: http://paxton.info/1035 or if you are not a registered
installer please call us on: 01273 811011 for more information.
Enrolment Card - must be presented when the system is first powered on
RD
CA
th
ON rd
to ck
TI t ca is cardthis pa t this the
t th ns in
en by
NC en
FU rolm
FUNCTION CARD
enrolment card
1. At installation, present this card to the
reader to validate the tokens in this pack
2. To re-validate a user token present this
enrolment card to the reader followed by the
user token
1.
2.
3.
4.
en
es ed
pr w
es toke
llo
, pr the
ke fo
tionate
r to ader
alla lid
usee re
st
/7
in to va
th
fo
at to
At
.in
1. ader
on
alid rd
xt
-v ca
re
re t
pa
en n
//
To
2. rolm ke
ttp:
to
en r
fo
in
use
es
Acc
Mor
on
xt
Pa
RD
CA
ON rd rd to thpack
TI t ca
ca is
EP
BE P!
BEE
is e
th
th th
is
NC en ent th ns in esented by
FU rolm on, pre esthe toke tokenerprfollow
ti at
ad
alla lid
usee re
st
/7
in to va
th
fo
at to
At
.in
1. ader
on
alid rd
xt
-v ca
re
re t
pa
en n
//
To
p:
2. rolm ke
htt
en r to fo:
in
use
es
Acc
Mor
on
xt
Pa
Take the enrolment card from the new pack of user cards.
Present the enrolment card to the reader.
The reader beeps and the LED's light up as the enrolment card is acknowledged.
All cards in the pack are now valid. The enrolment card can now be returned to it's pack.
RD
CA
N d
th
IO car card tois pack is e
th
is
CT ent
t th th
t th s in
en by
en ken
es ed
pr w
U lm
es
F ro
to
llo
, pr the
ke fo
tionate
r to ader
alla lid
usee re
st
/7
in to va
th
fo
at to
At
.in
1. ader
on
alid rd
xt
-v ca
re
re t
pa
en n
//
To
p:
2. rolm ke
htt
en r to fo:
in
use
Mor
Issuing tokens
Shadow cards
User cards
1.
2.
3.
4.
Across each double page there are pairs of cards - a user card and a corresponding shadow card.
Write the name of the user on the shadow card.
Take the user card from the opposite pouch and issue to the user.
Keep the card pack containing the shadow cards in a safe place.
Bar a user
1.
2.
3.
4.
When a card is lost or stolen it is important to bar the card from your system to avoid unauthorized access.
To bar a card or token take it's corresponding shadow card from the card pack.
Present the shadow card to the reader. This will remove the lost card or token from your system.
A barred card can re-validated by presenting the enrolment card followed by the user card to the reader.
Fail open release card - Compact systems are fail closed as default
BEE
P!
BE
FUNCTION CARD
fail open release
This card is used with systems where a fail open
electric release is used for the safe operation in the
event of a fire. Present the card to the reader to
drive a fail open release or a maglock. Present the
card again to revert to the fail closed operation
RD
en e
op in th
CA
il
N se re a farationader tont the
IO relea ms wsahefe opthe e .rePreeseration
to ck p
st the rd lo d o
N e
FU op
il
fa
sy r
ca ag se
ith d fo the a m clo
d use nt or fail
se se e
use is
is se Pre le to th
re
rd lea .
ca re fire en ert
is ric a op rev
Th ct t of fail to
ele en a in
ev ve aga
ri
d rd
ca
ess
Acc
xto
Pa
RD
en e
op in th
CA
il
N se re a farationader tont the
IO elea s whefe opthe e rePreseration
CTen r systermthecasard atoglockse.d ope
ith d fo the a m clo
U p
F il o
fa
d use nt or fail
se se e
use is
is se Pre le to th
re
rd lea .
ca re fire en ert
is ric a op rev
Th ct t of fail to
ele en a in
ev ve aga
dri rd
ca
ess
Acc
to
Pa
THIS CARD CAN ONLY BE USED WITH A FAIL OPEN LOCK.
1. Take the fail open release function card from the starter pack.
2. Present/swipe the card through the reader. The reader will beep for about a second.
3. The reader is now set to fail open mode. This allows safe operation of the door in case of fire: The lock will
release when the power is cut.
4. To revert to fail closed mode, swipe the card again and the reader will beep once.
Door open time (seconds)
AR d
EP
BE P!
BEE
RD d
CA car r when
fo
ON me cked llows:
op
st
TI n ti is unlot as fo
will
NC pe doord is se
in
FUoor o that prthese ente periothd e beep
C car r when
fo
ON me cked llows:
op
st
TI n ti is unlot as fo
will
NC pe doord is se
in
FUoor o that prthese ente periothd e beep
FUNCTION CARD
door open time card
The period that the door is unlocked for when a
valid token is presented is set as follows:
1. Present this card
2. Wait for the required period
3. Present this card again, the beeping will stop
rd ire ain,
rio n
ca
pe ke
is requ ag
e to
t th e card
Th lid
en r th is
va
es fo th
Pr ait
1. W esen
2. Pr
is
ss
3.
ce
on
Ac
d is
rd ire ain,
rio n
ca
pe ke
is requ ag
e to
t th e card
Th lid
en r th is
va
es fo th
Pr ait
1. W esen
2. Pr
ss
3.
ce
Ac
on
xt
xt
Pa
1.
2.
3.
4.
Pa
Take the 'door open time' card from the starter pack.
Present the card to the reader. The reader will start beeping.
Wait for the required period you wish the door to remain open.
Present the card again at the end of the period to set the open time. The beeping will stop.
Silent operation
EP
BE P!
BEE
P!
BE
FUNCTION CARD
silent operation
Present this card to silence the beeping noises
made by the reader. Present this card again to
re-enable the beeping noises
RD
ises to
CA
no ain
in ag
ON tio beepcard
TI era e thet this
NC op to silencPresenises
FU ent is cardreaderep. ing no
RD
ises to
CA
no n
N n epingrd agai
IO atio the beis ca
CT per silenceesentesth
Pr is
to
no
U t
F en
il
sil
rd er
ca ad in
is re ep
t th the e be
en by th
es
Pr ade bl
m -ena
re
t th the e be
th
en by
es
Pr ade bl
m -ena
re
es
on
es
on
Pa
1.
2.
3.
4.
Acc
xt
Acc
Pa
xt
Take the silent operation function card from the starter pack.
Present the card to the reader. The reader will beep.
The reader is now in silent operation mode.
Present the card again to disable silent operation mode. The reader will beep twice.
Specifications
Electrical
Voltage
Min
Max
11V DC
14V DC
100mA
Current
Switchable current
Environment
Operating temperature
Waterproof - Fixed cable
1A
Min
-20 °C
Max
+55 °C
Outdoor use
IPX7
Waterproof - P75 - Screw connection
Indoor use
Features
Min
Max
Number of Users
10,000
Number of Card Packs
100
1 sec
60 secs
Time zones (with additional time clock)
Access levels (Colour Zones)
Door open time
Silent operation
Yes
Can be used with fail OPEN locks
Yes
Can be used with fail CLOSED locks
Yes
Exit button input
Yes
Read Range
Token
Keyfob
Watchprox
P38
60 mm
40 mm
25 mm
P50
80 mm
50 mm
35 mm
P75
100 mm
60 mm
40 mm
Dimensions
Width
Height
Depth
P38
38 mm
78 mm
13 mm
P50
50 mm
100 mm
15 mm
P75
75 mm
143 mm
16 mm

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Create Date                     : 2011:11:24 16:16:10Z
Modify Date                     : 2018:02:23 15:42:00Z
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.6-c015 81.157285, 2014/12/12-00:43:15
Metadata Date                   : 2018:02:23 15:42Z
Creator Tool                    : Adobe InDesign CS5 (7.0.4)
Page Image Page Number          : 1, 2
Page Image Format               : JPEG, JPEG
Page Image Width                : 256, 256
Page Image Height               : 256, 256
Page Image                      : (Binary data 10225 bytes, use -b option to extract), (Binary data 9626 bytes, use -b option to extract)
Instance ID                     : uuid:103cfa55-e28c-4a20-9ee0-4a8a8e2a3fc4
Document ID                     : adobe:docid:indd:ada651e7-9362-11dc-ab69-add24a1f83db
Original Document ID            : adobe:docid:indd:ada651e7-9362-11dc-ab69-add24a1f83db
Rendition Class                 : proof:pdf
Derived From Instance ID        : ada651e6-9362-11dc-ab69-add24a1f83db
Derived From Document ID        : adobe:docid:indd:82864d34-4be3-11dc-a382-8bb9b0ffa574
History Action                  : saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved
History Instance ID             : xmp.iid:8941442C3F4AE011AA73974F4681A7E0, xmp.iid:8A41442C3F4AE011AA73974F4681A7E0, xmp.iid:35628E5F3F4AE011AA73974F4681A7E0, xmp.iid:36628E5F3F4AE011AA73974F4681A7E0, xmp.iid:9E9C6EF2404AE011AA73974F4681A7E0, xmp.iid:9F9C6EF2404AE011AA73974F4681A7E0, xmp.iid:3B305816414AE011AA73974F4681A7E0, xmp.iid:E53DFD2F434AE011BF788E4AC32BD1ED, xmp.iid:4E6E4A32444AE011BF788E4AC32BD1ED, xmp.iid:BC4EE09B444AE011B256CAD24FFF115E, xmp.iid:BEA806A8444AE011B256CAD24FFF115E, xmp.iid:1EC9E4A922DDE011B28EA12D4844CBDB, xmp.iid:3D88622C24DDE011B28EA12D4844CBDB, xmp.iid:55D84517B616E111867D87B921109DBB, xmp.iid:F7694383B616E111867D87B921109DBB, xmp.iid:33005606B716E111867D87B921109DBB, xmp.iid:97CE3837B716E111867D87B921109DBB, xmp.iid:98CE3837B716E111867D87B921109DBB
History When                    : 2011:03:09 11:20Z, 2011:03:09 11:20Z, 2011:03:09 11:21:26Z, 2011:03:09 11:30:02Z, 2011:03:09 11:32:42Z, 2011:03:09 11:33:19Z, 2011:03:09 11:33:42Z, 2011:03:09 11:48:44Z, 2011:03:09 11:55:58Z, 2011:03:09 11:58:55Z, 2011:03:09 11:59:15Z, 2011:09:12 10:36:17+01:00, 2011:09:12 10:47:05+01:00, 2011:11:24 16:05:12Z, 2011:11:24 16:08:14Z, 2011:11:24 16:11:53Z, 2011:11:24 16:13:15Z, 2011:11:24 16:15:43Z
History Software Agent          : Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0
History Changed                 : /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata
Doc Change Count                : 1036
Format                          : application/pdf
Title                           : INSTRUCTION - PROXIMITY P series compact reader
Creator                         : 
Producer                        : Adobe PDF Library 9.9
Trapped                         : False
Page Count                      : 4
EXIF Metadata provided by EXIF.tools
FCC ID Filing: USE333210

Navigation menu