Paxton Access 390530 PROXIMITY PANEL MOUNT HID READER User Manual

Paxton Access Ltd PROXIMITY PANEL MOUNT HID READER

User Manual

PAGE 1Ins-40159-US   PROXIMITY panel mount HIDTM reader - UL MountingCompatible with hands free tokensSuitabilitySecurity sensitive doors Wet environmentsTechnical SupportTechnical help is available:     Monday - Friday from 02:00 AM - 8:00 PM (EST)1.800.672.7298 supportUS@paxton-access.comDocumentation on all Paxton products can be found on our web site - http://www.paxton-access.com/Readers mounted togetherbetween readers12 inchesPaxton06/08/2011Token type and congurationThe reader will recognize 125 kHz HIDTM proximity tokens in format to produce a Wiegand output (26 to 50 bit) or EM4100 tokens to produce an ABA Track2 Clock and Data output.The reader scans the rst token presented after power up and will match the reader mode to the format discovered.If no token is read within 3 minutes of powering up, the reader will default to HIDTM. If you require EM4100 operation, power cycle the reader and present an EM4100 token within 3 minutes.Once in HIDTM or EM4100 mode, the reader will remain in that format.If used with Net2, the ACU reader port must be congured to read the correct data format.Where Wiegand cards are used, you must set the correct data format (e.g. Wiegand 26 bits) in the ACU reader port conguration or create a custom wiegand lter in the Net2 Server Conguration Utility.  For further information see: AN1010 - Conguring custom Wiegand formats < http://paxton.info/990 >
PAGE 2Cable extensionsWiringWiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70), local codes, and the authorities having jurisdiction.Use Max length TypeReader / Keypad 500 feet 8 core, shielded -  Beldon 9538, Alpha 1298C (22AWG)  or equivalentCable SpecicationPart number Description390-530-US PROXIMITY panel mount HIDTM readerOptionsConnection to the Net2 ACU reader port+12V DCRed LED Amber LED Green LED Clock/data1 Data/data0Not Required0V
PAGE 3Following the completed installation of this equipment, no further maintenance or testing is required.It is advisable to ensure that any third party backup power supplies or recovery procedures are checked regularly to ensure that the operation of the Paxton system is not compromised.MaintenancePart number DescriptionNot required Fits to studs on customer faciaParts KitReader installation and testThe panel mount reader is designed to t into a door entry panel. It ts behind a reader aperture of industry standard size (40 mm x 40 mm) and is supplied with a polycarbonate window to match.  See front page for tting detail.Holes are provided in each corner to t over 4 posts set in a 49 mm square formation.  Fixings are not provided as they will normally be supplied with the panel.When powered up, the reader will beep and all the LED's should display.  Presenting a user card to the reader will cause the LED's to briey change to a single Green or Red LED.Check the following FAQs section for assistance if any problems are encountered.FCC ComplianceThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
PAGE 412V DC140 mA115 kHz 135 kHz-35 °C  ( -31 °F ) +66 °C  ( + 151 °F )IPX72” 11/2”2 1/4 ”2 1/4 ”11/16 ”40 mm  (1 19/32”) 40 mm  (1 19/32”) -49 mm  (1 30/32”) 49 mm  (1 30/32”)Here is the list of topics about this product that receive the most technical support inquiries. We list them here to help you speed up the installation and trouble shooting process.Technical Help1 - Readers/Keypads not working.Q- Software settings - Conrm that the settings of the reader or keypad are correct. Q- Connections - Check the wiring and integrity of the connectors.  If possible, test this reader on the other port.Q- Extended cable - Belden 9538/9540 should be used up to a maximum of 500 feet. Twisted pair alarm cable shouldQ  not be used. To conrm that an extended reader cable is not at fault, wire the reader directly to the port.Q- Supply voltage - Conrm that the voltage is within specication. (see table) Q- User token - Conrm that the user token used for testing is OK by presenting it to a known working reader.Q- Interference - Conrm whether the reader works when tested 'in hand' and not mounted on the wall. Q  PROXIMITY readers should not be mounted back to back or close to other RF devices.2 - Readers / Keypads - Extending cable.QOnly Belden CR9538 / 9540 or a UL equivalent can be used for cable extensions. The maximum run is 500 feet.3 - Net2 - Using a door reader as a desktop reader. QIt is possible to congure a door reader to operate as a desktop reader: Q1 - Select the doors menu in the left hand Net2 pane.Q2 - Click on the door you wish to change the reader to act as a desktop reader.Q3 - Under the relevant reader tab, change the reader operating mode to 'Desktop Reader'.Q4 - The PC displays 'Would you like to accept desktop reader events from this reader at the PC?' ; click 'Yes'Q     Now when you present a blank or existing token to that reader it will allow you to add this new token or editQ     the existing one.   NOTE:QRemember to return the operating mode to the original setting once the cards have been readQ             or users will not be able to gain access through the reader. Q KP Reader - Ensure that Keypad type is set to 'None', otherwise the Desktop reader option will not be available.4 - Net2.  What to do if a user has no access - Check the reader LED's when a card is shown. Q- No LED's - the reader has no power. Q- No change in display - try the card on a known working reader. If there is still no response, replace the card. Q- Green LED ashing when a card is presented;  check relay 1 LED to check for activity and also the lock wiring. Q- Red LED is ashing when a card is presented;  check the validity of the user at the PC. Q   Check user's access level and ensure they should have access by clicking on Current Validity. Q   Check the 'Valid Until' date and conrm this has not expired. Q- Reinstate the ACU from the doors screen. Select the ACU's you wish to reinstate and then click OK.VoltageCarrier frequencySpecicationsOperating temperatures - all itemsElectricalEnvironment DimensionsMin MaxWidth Height DepthCurrentCable lengthRead Range Token Keyfob Hands Free TokenOutdoor Use Min MaxPanel mount reader Window sizeMounting studs - Square formation See front page for positionNot CompatibleReader xings are in metric to match industry standard access panel readersWaterproof 3 metres

Navigation menu