Paxton Access 500010 125 kHz Proximity Reader User Manual INSTRUCTION PROXIMITY marine reader

Paxton Access Ltd 125 kHz Proximity Reader INSTRUCTION PROXIMITY marine reader

Manual

Download: Paxton Access 500010 125 kHz Proximity Reader User Manual INSTRUCTION   PROXIMITY marine reader
Mirror Download [FCC.gov]Paxton Access 500010 125 kHz Proximity Reader User Manual INSTRUCTION   PROXIMITY marine reader
Document ID828842
Application ID39GEb6qKrKg3jR5Ff2IXlg==
Document DescriptionManual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize134.18kB (1677251 bits)
Date Submitted2007-08-14 00:00:00
Date Available2007-08-14 00:00:00
Creation Date2007-07-06 15:21:45
Producing SoftwareAdobe PDF Library 7.0
Document Lastmod2007-07-09 15:10:51
Document TitleINSTRUCTION - PROXIMITY marine reader
Document CreatorAdobe InDesign CS2 (4.0.5)

06/07/2007
Ins-30045-US
PROXIMITY marine reader
Technical Support
1 800 672 PAXT
support@paxton-access.co.uk
Technical help is available:
Monday - Friday from 5am - 5pm PST / 8am - 8pm EST
Other documentation on all Paxton products can be found on our web site - http://www.paxton-access.com/
Fitting
Fix the back plate to the wall with the stainlesss steel screws provided in the fitting kit. The small slot in the plate
edge should be positioned at the bottom.
Where the reader is to be fitted to a smooth surface, bulkhead, etc. a gasket is supplied to provide a weatherproof
seal between the back plate and the mounting surface. (The reader has its own integral seal)
Locate the reader in the keyhole slots provided in the back plate. Make sure that the locking pin is close to the slot
in the edge of the back plate. Rotate the reader clockwise until the locking pin engages in the slot.
To remove the reader, insert a small screwdriver into the cut out provided and use it to lift the locking pin. The
reader can then be rotated anticlockwise to release it from the back plate.
Wiring
Power
Relay 1
Relay 2
CAUTION: for 12v d.c. readers only. For
correct connection of old 5v readers, refer to
instructions.
Brown
Red
0v
Inputs
Exit
0v
PSU
5v
12v
OK
PSU
Exit
Tx
Rx
Tamper
Orange
Contact
0v
Contact
Tamper
Relay 2
White/Orange
Relay 1
Green
N.O.
Com
Alarm Output
Network
CAT5 cable coding
White/Green
N.O.
Com
Screen or spare cores
from network cable
0v
N.C.
24898 00000
Orange
+12v
N.C.
Keypad 1
Brown
Yellow
Serial number
241821
Black/White
Orange
Mauve
Green
Blue
Test ID: 012345678901
Green
Yellow
Reader 2
z-1440
Reader 1
Orange
Yellow
Blue
Mauve
Black/White
Brown
Yellow
Orange
Keypad 2
Red 12v dc
Brown
Green
Yellow
Blue
Control
unit
Alarm
Bell
12v
0v
N.C.
Door relay
Orange
Card reader or keypad
Brown
Power
Switch
Red 12V
N.O.
Com
Mauve
Black
Inputs
Contact
Exit
CAUTION: For 12V d.c. readers only.
For correct connection of old readers,
refer to instructions.
Cable extensions
Readers can be extended using Belden CR9540 10-core overall screened cable. The maximum cable length
between reader and control unit is 100 yards.
Power
Red
Relay 1
Relay 2
N.C.
N.O.
Com
0v
Contact
0v
Inputs
Exit
0v
PSU
5v
12v
OK
PSU
Exit
Tx
Rx
Tamper
Orange
Contact
Com
Tamper
Relay 2
White/Orange
Relay 1
0v
N.O.
Alarm Output
Network
Green
CAT5 cable coding
White/Green
+12v
N.C.
24898 00000
Screen or spare cores
from network cable
Brown
Keypad 1
Orange
Serial number
241821
Black/White
Brown
Green
Mauve
Test ID: 012345678901
Blue
Yellow
Yellow
Reader 2
z-1440
Green
Yellow
Reader 1
Orange
Orange
Blue
Mauve
Black/White
Brown
Yellow
Orange
Keypad 2
Red
Brown
Yellow
Blue
Mauve
Black
Contact
Exit
Inputs
White Labelled control units only provide
5v at the Red terminal. The red power wire
for the reader should be connected directly
to the 12v PCB supply terminal - as per
diagram.
Green
Control
unit
Door relay
Orange
Alarm
Card reader or keypad
Brown
Power
Switch
Red
Bell
12v
0v
N.C.
N.O.
Com
Frequently asked questions
Here is the list of topics about this product that receive the most technical support enquiries. We
list them here to help you speed up the installation and trouble shooting process.
1 - Readers/Keypads not working
. Software settings - Confirm that the settings of the reader or keypad are correct.
. Connections - Check the wiring and integrity of reader/keypad terminal connections.
. To confirm that an extended reader cable is not at fault, wire the reader direct into the reader port. If the reader
works, this indicates a problem with the cable.
. Supply voltage - confirm that the reader has sufficient voltage.
. User token - Check that the user token used for testing the reader is operational.
. Interference - Confirm whether the reader works when tested ‘in hand’ and not mounted on the wall. Ensure that
readers are not mounted back to back or there is not interference from other RF devices.
2 - Readers / Keypads - Extending cable
. Only Belden CR9538 /9540 can be used for cable extensions. CR9538 is 8 core for up to 25m, CR9540 10 core
for 25-100m (maximum extension). When using CR9540, the two additional cores should be used to double up for
power.
3 - Net2 - What to do if a user has no access
. Check the reader LEDs when a card is shown:
No LEDs - the reader has no power.
No change in display - try the card on a known working readers. If there is still no response, replace the card.
Green LED flashing when a card is presented, check the Relay 1 LED to check activity and the wiring to the lock.
Red LED is flashing when a card is presented, check the validity of the user at the PC.
- Check user’s access level and ensure they have access by clicking on Current Validity.
- Check the ‘Valid Until’ date and confirm this has not expired.
Reinstate the ACU from the doors screen. Select the ACU’s you wish to reinstate and then click OK.
4 - Switch2 - Adding an additional card pack
. You need to be in possession of the original enrolment card. Present the original enrolment card to the reader
and the Amber LED will flash, Green & Red LEDs will be off, then present the Enrolment card from the new card
pack; the reader will beep and all LEDS will be lit. The additional cards will now be valid. Repeat this with each
reader and with any additional card packs. Any valid enrolment card can be used to add further packs. This is the
same for enrolling function card packs onto a system.
5 - Switch2 - How to reset the controller
. Disconnect the power and remove the wires from the Green and Mauve terminals
. Insert a wire link between the Green and Mauve terminals
. Reconnect the power (the unit will bleep 4 times)
. Disconnect the power and remove the link wire, reconnect the Green and Mauve wires
. Reconnect the power (the unit will bleep 3 times per second). The unit is ready to be enrolled.
Suitability
Security sensitive doors
Mounted on metal surface
Wet environments
Readers mounted together
300mm
between
readers
Specifications
Environment
Operating temperatures - all items
Min
-25 °C (-4 °F)
Max
+55 °C
(+131°F)
Waterproof
IPX7
5 yards
Cable length
Electrical
Voltage
Min
8v DC
Current
Max
14v DC
130 mA
125 kHz
Carrier frequency
600 µs
Clock and data bit period
Read Range
Dimensions
Token
Keyfob
Hands Free Token
1 1/2”
1”
15”
Diameter
Depth
4”
5/8”
The declaration of conformity may be
consulted at - http://paxton.info/596
FCC Compliance
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this
device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 4
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:a1e0555f-6d5f-4486-b97d-f73e931a5f23
Producer                        : Adobe PDF Library 7.0
Trapped                         : False
Create Date                     : 2007:07:06 15:21:45+01:00
Metadata Date                   : 2007:07:09 15:10:51+01:00
Modify Date                     : 2007:07:09 15:10:51+01:00
Creator Tool                    : Adobe InDesign CS2 (4.0.5)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 7478 bytes, use -b option to extract)
Instance ID                     : uuid:0563beb3-6f3d-4d4e-865d-eb45634d8b0a
Rendition Class                 : proof:pdf
Document ID                     : adobe:docid:indd:5beffd37-2bc3-11dc-91d9-efe780b5d25d
Derived From Instance ID        : aa34489c-2bbe-11dc-b206-82308679df03
Derived From Document ID        : adobe:docid:indd:5a55ee51-2a17-11dc-a128-b4c05ba2a019
Manifest Link Form              : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 300.00, 72.00, 72.00, 72.00, 72.00, 600.00, 72.00, 72.00, 600.00
Manifest Placed Y Resolution    : 300.00, 72.00, 72.00, 72.00, 72.00, 600.00, 72.00, 72.00, 600.00
Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches, Inches
Manifest Reference Document ID  : uuid:8e68e80f-29c7-4ef0-97f2-2d95e832cc3e, uuid:0FA0EF2C182ADC11BE6183D689F656CF, uuid:08BF5E45D72ADC11B279D9211005B156, uuid:F847E9EF072ADC118230E36F6F077236, uuid:FB47E9EF072ADC118230E36F6F077236, adobe:docid:photoshop:f86ae1bc-64fb-11db-8a3e-971789a20d84, uuid:4E0E8A9D9C2BDC1187C4E7C77EFC0C4A, uuid:F447E9EF072ADC118230E36F6F077236, adobe:docid:photoshop:f86ae1bc-64fb-11db-8a3e-971789a20d84
Manifest Reference Instance ID  : uuid:c73e28ff-f921-48d6-b5ec-6397ef8042f1, uuid:37c489c7-2d44-45cd-b5cf-8c605e050cf4, uuid:a45ec15f-08c9-4e8a-90cb-74dd296709cd, uuid:282118b4-e8d5-448b-9e2c-6002879a82d9, uuid:1a07c71a-41a0-48da-b294-f745f055eac7, uuid:c8892a47-7352-4dbe-9810-6e7dae12153f
Format                          : application/pdf
Title                           : INSTRUCTION - PROXIMITY marine reader
Creator                         : Adobe InDesign CS2 (4.0.5)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: USE500010

Navigation menu