Paxton Access 901172 Net2 PaxLock – 72mm Euro lock case User Manual INSTRUCTION Net2 PaxLock

Paxton Access Ltd Net2 PaxLock – 72mm Euro lock case INSTRUCTION Net2 PaxLock

User Manual

PAGE 102/23/2012Parts listTools ListPower DrillDrill bits 3/8", 5/8"Philips screwdriverSmall at blade terminal screwdriverPencil4mm Allen key (supplied)Technical SupportTechnical help is available:     Monday - Friday from 02:00 AM - 8:00 PM (EST)1.800.672.7298 supportUS@paxton-access.comIns-30168-US Net2 PaxLock Documentation on all Paxton products can be found on our web site - http://www.paxton-access.com/Net2Air  Site  Surveyor    (690-200-US).                  This access control unit uses wireless communication.  It is recommended that a Net2Air site surveyor is used to determine the best position for the bridge and control units.This wireless unit requires a Net2Air bridge to communicate with the server PC.Paxton12345 6789AAAA--++1) Front Lock Assembly2) Rear Lock Assembly3) Door Handle x 24) Mounting screw (1 1/4") x 25) Mounting screw ( 1 1/2") x 26) Mounting screw ( 1 3/4" ) x 27) 8 mm Spindle8) AA battery x 49) 4 mm Allen KeyThis unit requires Net2 v4.23 or later software. Call Technical Support if you require advice.
PAGE 2The lock (not supplied) must rst be tted to the door.Slide the spindle through the lock to allow the template to locate over it. Ensure that the template is square to the door edge by using the top and bottom ruler scales.Mark the 2 x 3/8" and 1 x 5/8" holes. Remove the template and repeat the procedure for marking out the other side of the door.Installing the hardware Step 1 - Marking outStep 2 - DrillingDrill the 2 x 3/8" holes for the mounting screws and 1 x 5/8" hole for the wiring harness.To ensure accuracy you should drill these holes from both sides of the door towards the centre. This also avoids the risk of damaging the door face when the drill breaks through.Step 3 - Contact switch (optional)If a contact switch is to be tted, an additional hole is required in the edge of the door.Drill a hole of the required size to receive the switch assembly. This should intersect the 5/8" hole drilled previously to take the wiring harness.Feed the door contact wires through the door to exit on the inside.Ø 16 37105Ø 10Paxton70605040301055151502025253535455565754555657510203040607050The spindle is locked into the front lock assembly by means of a spring loaded pin.Ensure that the spindle pin and the hole in the square drive are in alignment before depressing the pin and sliding the bar into the assembly. The pin will then latch into the hole securing the spindle in place.Step 4 - Attach the Spindle
PAGE 3Step 9 - Fitting the rear coverPresent the front lock assembly to the door passing the wiring harness through the 5/8" hole.Present the rear lock assembly to the door and join the two parts together with the two mounting screws.Step 5 - Mounting on the doorStep 6 - WiringPlug the wiring harness into the socket in the rear lock assembly.Locate the top of the cover over the housing and push ush to the door.Clip in the 4 x AA batteries with reference to the label displayed below the holder assembly.Step 8 - Fitting the batteriesWhere a contact swich is tted, connect the wires to the terminal block provided on the pcb.Step 7 - Wiring (contact switch option)Mounting screws are provided in three lengths.Short - Door width 1 1/4" to 1 3/4"Med - Door width 1 1/2" to 2"Long - Door width 1 3/4" to 2 1/4"
PAGE 4The current specication for compatible PC hardware, network and operating systems is available on our website at the following link: http://paxton.info/720Net2 has NO PaxLock detection function. It is recognised that there could be security issues if the wireless units were detectable from outside the site. During installation, a PaxLock unit binds to a Net2Air bridge which will then only talk to registered units.Devices cannot be added to the system if commissioning mode is disabled.An entry is then made on the Doors screen and a special icon is used to denote the wireless connection.A PaxLock must bind to a Net2Air bridge before it will enrol itself onto the Net2 system. The term 'bind' is used to denote the xed relationship between a wireless unit and its bridge.1. Create a user record in the database and assign a Net2 token to the user. (This record can be deleted after    the installation is complete.)2. You must now wake up the PaxLock by using the front push button.3. Present the user token to the PaxLock.4. The Red and Green LED's will ash alternately while the unit congures.The PaxLock transmits the number and waits for a response from Net2. If more than one bridge replies, the unit checks the signal strength and selects the strongest bridge to communicate with.  The Net2 software conrms that the token number is in the database and registers the PaxLock/bridge binding.  The LED's will go out when the process has nished.The software must be in commissioning mode which is the default setting. If this has been turned off it must be enabled in the Server Conguration Utility.Enrolling a PaxLockThe Net2 software should be loaded on the controlling PC with at least one Net2Air bridge installed.Full documentation is supplied with the Net2Air bridge unit and also from the website as follows:XAN1051 - Installing Net2 software < http://paxton.info/1520 >XIns-40084-US  Net2Air USB  bridge < http://paxton.info/1453 >XIns-40085-US  Net2Air Ethernet bridge < http://paxton.info/1192 >Software installationDownload the latest version of Net2 software at: http://paxton.info/1438 before commissioning this product. Step 10 - Fitting the handlesFit the two handles and secure with the grub screws provided.Check the mechanical operation of the lock and that the handles operate freely.Some of the Net2 features (e.g. Fire alarm integration, Anti-passback) are not available on this product as wireless communication is not suitable for data critical applications.
PAGE 5Presenting a valid user token to the unit will cause the LED to briey ash Green and the door will unlock.  The presentation of a barred or unknown user token is indicted by a Red LED display.The external handle is only engaged once access has been granted.  The inside handle is always engaged.Normal Operation - LED IndicationsSoftware congurationReader: Local settings for the reader.Output: Congures the lock for timed release or toggle mode.Alarm: Enables/Disables the door alarm functions.          (requires contact switch)Events: Shows the events for this control unit only.Access Rights: Lists users who have access through this door.Door name: Name the Door.Door open time: Set the door open time.Unlock the Door during: Holds the door unlocked during this timezone. - Set to  'At No Time'  for normal user operation.Red ashRed and Green ash togetherA valid user card has been presented and the handle is engagedAn invalid user card has been presented - No access grantedLED indicationsGreen ashThe unit is conguring - Please wait.The access control unit connects to the Net2 software running on the PC using Paxton Net2Air proprietary wireless technology. A Net2Air bridge enables communication from the Net2 software to the Paxton wireless products.Radio signals do not always behave as you might expect.  For example, a cell phone that displays a full signal on one part of the site will lose signal completely only a few feet away. These problems can be addressed by using the Net2 site surveyor kit  (690-200-US)See also:  XAN1095 - Net2 nano - How does it work? < http://paxton.info/974 >X               AN1096 - How to plan a Net2 nano installation < http://paxton.info/975 >X               Ins-30096-US  - Net2Air site surveyor < http://paxton.info/1193 >Net2Air wireless communicationRadio frequencyThe unit is set to channel 11 (2.405 GHz). This product should not be installed within 10 feet of any other radio (LAN/Wi-Fi) equipment to reduce the possibility of interference.Red and Green ash alternatelyThe unit is not bound to a bridge.
PAGE 6Battery replacement1. Remove the inside handle from the door by removing the securing grub screw.2. Remove the cover by holding the bottom edge and pulling it towards you. The cover will lift off at the top when    the bottom edge is clear of the housing.3. Remove and replace batteries.4. Ret the cover and handle.Recovery from a at battery Should the battery pack become discharged, the latch will no longer function. This could be in the locked or unlocked state.Holding a PP3  9V battery up to the contacts on the bottom of the unit will allow the circuitry to operate normally. A valid user card can then be used to open the door to access the batteries. +ve-veThe PaxLock is a standalone unit and stays asleep while there is no user activity. The Net2 server cannot wake up the unit. If the PIR is activated or the front button is pressed, it powers up the reader circuits in readiness for a token read.  Should nothing occur within 3 seconds, the unit will go back to sleep.If a token is read, then the PaxLock moves into full operation. The token number is checked against the stored database and access is granted or denied as per a standard Net2 control unit.The PaxLock now sends this data via its Net2Air bridge connection to the Net2 server software. If any updates need to be sent to the unit, including changes to the user data, these are transmitted back.  The unit will then go back to sleep waiting for further activity.After 1 hour of inactivity, the PaxLock will send a heartbeat to the Net2 PC which responds with any updates.  This keeps the PaxLock updated even when there is no activity at the door and maximises battery life.Sleep modeAs the battery voltage falls the unit will update the Net2 server with its battery condition.  This voltage level is displayed as a colored battery icon alongside the door in the Doors screen. When the batteries approach the end of their life an Event is sent to Net2.Using Net2 Trigger and Actions, an email or text message can be sent to a staff member or engineer to schedule a battery change.Low battery warningDuring the 1 hour sleep period, any changes made at the PC will not be received. If an immediate update is required, the unit must be woken up by pressing the front button or presenting a user card.Where a door is held unlocked by software, it will still receive updates every hour. To force an immediate update, the unit must by activated by pressing the front button.  A card can then be presented to initiate the update request.Where the lock has a key override, this will always be available to unlock the door and gain entry.Low Power mode is available as a global setting in the Net2 server conguration utility or on individual Doors screens. It is very useful for units that require low activity but have a high rate of passing trafc (e.g. corridor). In low power mode the PaxLock must be woken up by pressing the front button. This ensures that incidental handle or PIR activity does not cause an unnecessary drain on battery power or communications activity.If woken, the PaxLock will initiate a transmission if it has been asleep for more than 1 hour.  It will always initiate an update every six hours.Low power mode
PAGE 7PaxLock resetThe PaxLock holds address information for the bridge that it is bound to. This will cause problems if the unit is to be used on another system.The unit requires a hardware reset to clear its bridge information.  This is achieved as follows:1. Remove the inside handle from the door by loosening the securing grub screw.2. Remove the cover by holding the bottom edge and pulling it towards you. The cover will lift    off at the top when the bottom edge is clear of the housing.3. Locate the red reset button at the top of the unit.4. Hold the button down and wake up the unit by pressing the front push button.    The unit will give a beep when the reset has started. You can now release the reset button.5. The Red and Green LED's will both ash until the process has nished.6. Ret the cover and handle.7. You can now enrol the unit.10,000250641010065 ft3,5841 inch 1/4 inch4 x AA0 °C (-32 °F) +55 °C (+131 °F)IPX46V DC1 1/2 inch 13 inch 1 3/8 inch6 1/4 inch 13 inch 4 inchOperating temperature - Battery limitsEnvironment DimensionsFeaturesExternal useMinWidth HeightMaxDepthMin MaxAccess LevelsTime ZonesDoor open timeACU's per Net2Air bridge - RecommendedEvents stored in ACU with no server connectionNumber of CardsSpecicationsYesNet2Air bridge (data lines) per systemNet2Air wireless range to ACUThe declaration of conformity is available on request. Contact details are provided at:   http://paxton.info/596LowReader/Keypad module (Required space on Door)Total outside dimensions (includes handle clearance) Battery TypeTypical Battery LifeVandal resistanceRead Range KeyfobTokenThis product is not suitable for retail sale.  All warranties are invalid if this product is not installed by a trained technician.Use site surveyorVoltage2 years or 30,000 ops 3 years or 60,000 ops Max = Low power modeThis device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Changes or modications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment. FCC Compliance1 sec 60 secs

Navigation menu