Paxton Access Z99MU10 Proximity Mullion Reader User Manual INSTRUCTION Mullion PROXIMITY reader UL

Paxton Access Ltd Proximity Mullion Reader INSTRUCTION Mullion PROXIMITY reader UL

User Manual

Download: Paxton Access Z99MU10 Proximity Mullion Reader User Manual INSTRUCTION   Mullion PROXIMITY reader   UL
Mirror Download [FCC.gov]Paxton Access Z99MU10 Proximity Mullion Reader User Manual INSTRUCTION   Mullion PROXIMITY reader   UL
Document ID1287883
Application IDI7knO9CLrnwNgQGNPO3PxA==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize57.95kB (724380 bits)
Date Submitted2010-05-28 00:00:00
Date Available2010-05-28 00:00:00
Creation Date2010-05-20 11:23:23
Producing SoftwareAdobe PDF Library 7.0
Document Lastmod2010-05-20 11:24:00
Document TitleINSTRUCTION - Mullion PROXIMITY reader - UL
Document CreatorAdobe InDesign CS2 (4.0.5)

05/20/2010
Paxton
Ins-40015-US Mullion PROXIMITY reader - UL
Technical Support
1.800.672.PAXT
Technical help is available:
support@paxton-access.com
Monday - Friday from 02:00 AM - 8:00 PM (EST)
Saturday from 04:00 AM - 08:00 AM (EST)
Documentation on all Paxton products can be found on our web site - http://www.paxton-access.com/
Suitability
Security sensitive doors
Mounted on metal surface
Wet environments
Readers mounted together
12 inches
between
readers
Fitting
This reader is designed to read EM4100 tokens. It will provide Clock and Data
output for Paxton (Net2 / Switch2).
PAGE 
Options
Part number
Description
353-110-US
Mullion PROXIMITY reader
+V out
Red
Power
Power
Relay 1
Relay 1
Relay 2
Relay 2
00v
Inputs
Contact
Contact
5v
12V
12v
OK
OK
PSU
PSU
Tamper
Tamper
Exit
Exit
Tx
Tx
Rx
Rx
Blue
Clock/D
Alarm
PowerAlarm
Power
Door relay
Yellow
Data/D0
Door relay
Card reader or keypad
Card reader or keypad
Control
unit
Green LED
Green
0V
0v
Exit
Exit
PSU
PSU
SSwitch2
witch
Amber LED
Orange
N.O.
N.O.
Com
Com
00v
Red2V
12V
Red LED
Brown
Com
Com
Alarm
Output
Alarm
Output
Inputs
CAUTION: for 12v d.c. readers only. For
correct connection of old 5v readers, refer to
instructions.
24898 00000
Red LED
Brown
Serial number
241821
Orange
Orange
Net2 control unit
N.O.
N.O.
Tamper
Tamper
Contact
Contact
Relay22
Relay
White/Orange
White/Orange3
Relay
Relay11
Green
Green
0V 0v
N.C.
N.C.
NetwoNetwork
rk
CA
T5 cacable
ble codcoding
ing
CAT5
White/Green
White/Green 1
Amber LED
Orange
Green LED
Green
Test ID: 012345678901
z-1440
Screen or
from
Screen
orspare
sparecores
cores
network
cable
from
network
cable
12V
+12v
N.C.
N.C.
Keypad 1
Keypad 1
Clock
Orange
Clock/D1
Blue
0V out
Black/White
Data/D0
Yellow
Media Detect
Mauve
Load
Brown
Media Detect
Mauve
BlueClock/D1
Data
Yellow
Reader 2
Net2
Reader 1
Data/D0
Yellow
Reader 2
Keypad 2
Reader 1
Green LED
Green
0V out
Black/White
Keypad 2
outdc
Red+V
12v
Red LED
Brown
Amber LED
Orange
Load
Brown
Data
Yellow
Orange
Clock
Wiring
Bell
Bell
2V
12v
Switch2 control unit
(not evaluated by UL)
0V
0v
N.C.
N.C.
N.O.
N.O.
COM
Com
Mauve
Media Detect
Black
0V
CAUTION:
For 2Vd.c.
CAUTION:
For 12V d.c.
readers
readers only. For correct
only. For corr
ect connection of old
connection of old readers,
readers, refer
referto
toinstructions
instructions..
Inputs
Exit
Exit
Inputs
Contact
Contact
Wiring methods shall be in accordance with the National Electrical Code (ANSI/NFPA70),
local codes, and the authorities having jurisdiction.
All interconnecting devices must be UL Listed.
Cable extensions
Cable Specification
Use
Max length
Type
Reader
100 yds
10 core, shielded - Beldon 9540, Alpha 1298C (22AWG) or equivalent
NOTE: Where selected, any equivalent cabling / wire must be ‘ UL Listed ‘
PAGE 
Fitting Kit
Option
Part number
Mullion
Fitting Kit fk1-085
Description
5 off - Cable clips
3 off - No6 x
3/4in
pozi round woodscrew - zinc
3 off - Wall plugs 22mm
1 off - 8mm x 3mm small pozi pan self tapping screw - zinc
Unit installation / test
When choosing a location for the reader, ensure that it is at least 12 inches from other readers. This will include
readers mounted on the other side of the same wall as the radio signal will cause interference and reduce the read
range. The reader should not be used on metal surfaces as the reflected signal will also reduce the read range.
Standard Unit - Drill a hole in the surface for the rear data cable. Secure the unit to the surface with three screws
as per fitting diagram on page 1. Suitable screws and fixings are provided for fitting the unit to a wall. Ensure the
data cable has free access at the rear.
A choice of black and white covers are also provided. Hook the required cover over the top of the reader, press
home at the bottom and secure with the single fixing screw.
The reader will beep and all the LED’s should display after powering on the control unit. Presenting a user card to
the reader will cause the LED’s to briefly change to a single Green or Red LED.
Check the following FAQs section for assistance if any problems are encountered.
Maintenance
Following the completed installation of this equipment, no further maintenance or testing is required.
It is advisable to ensure that any third party backup power supplies or recovery procedures are checked regularly
to ensure that the operation of the Paxton Access system is not compromised.
FCC Compliance
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation. Changes or modifications not expressly approved by
the party responsible for compliance could void the user’s authority to operate the equipment.
PAGE 
Technical Help
Here is the list of topics about this product that receive the most technical support inquiries.
We list them here to help you speed up the installation and trouble shooting process.
1 - Readers/Keypads not working.
Q- Software settings - Confirm that the settings of the reader or keypad are correct.
Q- Connections - Check the wiring and integrity of the connectors. If possible, test this reader on the other port.
Q- Extended cable - Belden 9540 should be used up to a maximum of 100yds. Twisted pair alarm cable should
Q not be used. To confirm that an extended reader cable is not at fault, wire the reader directly to the port.
Q- Supply voltage - Confirm that the voltage is within specification. (see table)
Q- User token - Confirm that the user token used for testing is OK by presenting it to a known working reader.
Q- Interference - Confirm whether the reader works when tested ‘in hand’ and not mounted on the wall.
Q PROXIMITY readers should not be mounted back to back or close to other RF devices.
2 - Readers / Keypads - Extending cable.
QOnly Belden CR9538 / 9540 can be used for cable extensions. CR9538 8 core for up to 25yds, CR9540 10 core
Qfor 25-100yds (maximum). With CR9540, the two additional cores should be used to double up the power.
3 - Net2 - Using a door reader as a desktop reader.
QWhen there is no desktop reader on site it is possible to configure a door reader to operate as a desktop reader:
Q1 - Select the doors menu in the left hand Net2 pane.
Q2 - Click on the door you wish to change the reader to act as a desktop reader.
Q3 - Under the relevant reader tab, change the reader operating mode to ‘Desktop Reader’.
Q4 - The PC displays ‘Would you like to accept desktop reader events from this reader at the PC?’ ; click ‘Yes’
QNow when you present a blank or existing token to that reader it will act in the same way as a USB desktop
Qreader, enabling you to add new tokens or edit existing ones.
NOTE:QRemember to return the operating mode to the original setting once the cards have been read
Qor users will not be able to gain access through the reader.
QKP Reader - Ensure that Keypad type is set to ‘None’, otherwise the Desktop reader option will not be available.
4 - Net2. Two readers into one reader port.
QTwo readers can be wired in parallel. - Color for Color. This can be useful in situations such as a barrier where
Qdual height readers are required; one for cars, one for trucks.
5 - Net2. What to do if a user has no access - Check the reader LED’s when a card is shown.
QQQQQ
Q-
No LED’s - the reader has no power.
No change in display - try the card on a known working reader. If there is still no response, replace the card.
Green LED flashing when a card is presented; check relay 1 LED to check for activity and also the lock wiring.
Red LED is flashing when a card is presented; check the validity of the user at the PC.
Check user’s access level and ensure they should have access by clicking on Current Validity.
Check the ‘Valid Until’ date and confirm this has not expired.
Reinstate the ACU from the doors screen. Select the ACU’s you wish to reinstate and then click OK.
Specifications
Environment
Operating temperatures - all items
Waterproof
Min
Max
-35 °C ( -31 °F )
+66 °C ( + 151 °F )
IPX7
Outdoor Use
10 feet
Cable length
Electrical
Min
Max
12V DC
Voltage
130 mA
Current
125 kHz
Carrier frequency
600 µs
Clock and data bit period
Dimensions
Read Range
Depth
Width
Height
1 3/4 inch
4 inch
Token
Keyfob
Hands Free Token
3 inch
2 inch
4 feet
3/4
inch
PAGE 

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Page Count                      : 4
XMP Toolkit                     : XMP toolkit 2.9.1-14, framework 1.6
About                           : uuid:d3b40d59-9006-4ae6-97ea-a8bc8b9b331d
Producer                        : Adobe PDF Library 7.0
Trapped                         : False
Create Date                     : 2010:05:20 11:23:23+01:00
Metadata Date                   : 2010:05:20 11:24:00+01:00
Modify Date                     : 2010:05:20 11:24:00+01:00
Creator Tool                    : Adobe InDesign CS2 (4.0.5)
Thumbnail Format                : JPEG
Thumbnail Width                 : 256
Thumbnail Height                : 256
Thumbnail Image                 : (Binary data 6477 bytes, use -b option to extract)
Instance ID                     : uuid:7c7ea822-4f7f-43d1-b327-8796f2dd1e9c
Rendition Class                 : proof:pdf
Document ID                     : adobe:docid:indd:6eda1fef-52c9-11df-a4e3-c2731754c4fc
Derived From Instance ID        : c0ed9629-26b5-11df-8392-badbe73b6fd3
Derived From Document ID        : adobe:docid:indd:72fb475d-0cc1-11de-86e6-b4537f82d3e1
Manifest Link Form              : ReferenceStream, ReferenceStream, ReferenceStream
Manifest Placed X Resolution    : 72.00, 600.00, 72.00
Manifest Placed Y Resolution    : 72.00, 600.00, 72.00
Manifest Placed Resolution Unit : Inches, Inches, Inches
Manifest Reference Instance ID  : uuid:a27c06a5-0165-4819-8b7c-c5a8e9794cd2, uuid:207d20d3-83b8-4093-88cb-c1238db5de76
Manifest Reference Document ID  : uuid:C18CBA7D2100DF11AE179FBCC0B84ED9, adobe:docid:photoshop:c0876e9a-64fb-11db-8a3e-971789a20d84, uuid:1d686997-20a0-4ddc-851b-cce15bb5b5da
Format                          : application/pdf
Title                           : INSTRUCTION - Mullion PROXIMITY reader - UL
Tagged PDF                      : Yes
Creator                         : Adobe InDesign CS2 (4.0.5)
EXIF Metadata provided by EXIF.tools
FCC ID Filing: USEZ99MU10

Navigation menu