PG.74A.01.T.E Brochure

1000500965-Brochure 1000500965-Brochure 1000500965-Brochure B6 unilog cesco-content

2016-10-27

: Pdf 1000349133-Brochure 1000349133-Brochure B6 unilog

Open the PDF directly: View PDF PDF.
Page Count: 192

DownloadPG.74A.01.T.E  Brochure
Open PDF In BrowserView PDF
Cutler-Hammer

Miniature and Molded Case Circuit Breakers
Table of Contents

March 1999

1

Miniature Circuit Breakers

Molded Case Circuit Breakers

Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

QUICKLAG® Industrial Circuit Breakers

Series C Circuit Breakers

Circuit Breakers, Plug-on Types HQP, QPHW,
QHPX, QHPW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Ground Fault Circuit Breakers, Plug-on Types
QPGF, QPHGF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Ground Fault Equipment Protectors, Plug-on Types
QPGFEP, QPHGFEP . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Circuit Breakers, Bolt-on Types BA, QBHW, HBAX,
HBAW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Ground Fault Circuit Breakers, Bolt-on Types
QBGF, QBHGF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Ground Fault Equipment Protectors, Bolt-on Types
QBGFEP, QBHGFEP . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Circuit Breakers, Cable-in/Cable-out
1-Inch per Pole Types QC, QCHW, QHCX, QHCW . . . 9
1/2-Inch per Pole Types QCR, QCF, QCRH, QCFH . . . 10
Ground Fault Circuit Breakers, Cable-in/Cable-out
Types QCGF, QCHGF . . . . . . . . . . . . . . . . . . . . . . . . . 13
Ground Fault Equipment Protectors, Cable-in/
Cable-out Types QPGFEP, QCHGFEP. . . . . . . . . . . . . 13
Solenoid-operated, Remote-controlled Types
GHBS, GBHS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
International Rated Circuit Breakers . . . . . . . . . . . . . . . . 16
Special Application Breakers. . . . . . . . . . . . . . . . . . . . . . 17
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Factory Modifications, Factory Installed Terminals . . . 19

G-Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
F-Frame. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
J-Frame. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
K-Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
L-Frame. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
M-Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
N-Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
R-Frame . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Supplementary Protectors
Type SPCL Current Limiting . . . . . . . . . . . . . . . . . . . . . . 20
Type SPHM Hydraulic Magnetic . . . . . . . . . . . . . . . . . . . 23
Circuit Breaker Electronic Catalog
Navigation Chart of Attached CD-ROM . . . . . . . . . . . . 192

25
31
37
43
55
67
75
89

Specific Application Circuit Breakers
Motor Circuit Protectors . . . . . . . . . . . . . . . . . . . . . . . . 107
Earth Leakage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113
Current Limiting
Non-fused . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
Fused . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117
Engine Generator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
Direct Current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133
Mining Service . . . . . . . . . . . .See CD-ROM SA.74A.01.T.E
Navy . . . . . . . . . . . . . . . . . . . .See CD-ROM SA.74A.01.T.E
Add-on Ground Fault Protection . . . . . . . . . . . . . . . . . 135
Internal Accessories
Alarm Switch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Auxiliary Switch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Auxiliary and Alarm Switch Combination . . . . . . . . . .
Shunt Trip. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Low Energy Shunt Trip . . . . . . . . . . . . . . . . . . . . . . . . .
Undervoltage Release Mechanism. . . . . . . . . . . . . . . .
Terminal Block . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Communication Kits . . . . . . . . . . . . . . . . . . . . . . . . . . .

139
142
145
147
152
153
160
160

External Accessories

■

Product Guide

■

Selection Data

■

Time Current
Curves

■

Dimensions

Termination Hardware . . . . . . . . . . . . . . . . . . . . . . . . .
Mounting Hardware. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Locking Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Interlocking Devices. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Electric Operators . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Plug-in Adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Rear Connecting Studs . . . . . . . . . . . . . . . . . . . . . . . . .
Panelboard Connecting Straps. . . . . . . . . . . . . . . . . . .
Handle Mechanisms . . . . . . . . . . . . . . . . . . . . . . . . . . .

161
163
168
170
172
174
175
177
178

Circuit Breaker Enclosures . . . . . . . . . . . . . . . . . . . . . . 187
Website: www.cutlerhammer.eaton.com
Copyright Cutler-Hammer Inc., 1999.
All Rights Reserved.
PG.74A.01.T.E

Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 191

2

Cutler-Hammer

Miniature Circuit Breakers
Selection Guide

Circuit
Breaker
Type

Circuit
Breaker
Type Code

Cont.
Ampere
Rating
At 40°C

Number
of
Poles

March 1999

Volts
Ac

Dc

Federal
Spec.
W-C-375b

Interrupting Ratings rms Symmetrical Amperes
120

120/240

Page
Number

Dc➁

Ac Ratings Volts
240

24-48

62.5

80

Quicklag Industrial Circuit Breakers➀
Plug-in, Bolt-on, Cable-in/Cable-out
HQP
HQP
HQP
QPHW
QPHW
QPHW
QHPX
QHPX
QHPX
QHPW
QHPW
QHPW
QPGF
QPGF
QPHGF
QPHGF
QPGFEP
QPGFEP
QPHGFEP
QPHGFEP
BAB
BAB
BAB
QBHW
QBHW
QBHW
HBAX
HBAX
HBAX
HBAW
HBAW
HBAW
QBGF
QBGF
QBHGF
QBHGF
QBGFEP
QBGFEP
QBHGFEP
QBHGFEP
QC
QC
QC
QCF
QCF
QCF
QCR
QCR
QCR
QCHW
QCHW
QCHW
QHCX
QHCX
QHCX
QHCW
QHCW
QHCW
QCGF
QCGF
QCHGF
QCHGF
QCGFEP
QCGFEP
QCHGFEP
QCHGFEP

P
P
P
P
P, GF
P, GF
P, GFEP
P, GFEP
B
B
B
B
B, GF
B, GF
B, GFEP
B, GFEP
C
C

C
C
C
C, GF
C, GF
C, GFEP
C, GFEP

10-70
10-125
10-100
15-70
15-125
15-100
15-70
15-100
15-100
15-30
15-30
15-20
15-40
15-50
15-30
15-50
15-40
15-50
15-30
15-30
10-70
10-125
10-100
15-70
15-125
15-100
15-70
15-100
15-100
15-30
15-30
15-20
15-40
15-50
15-30
15-30
15-40
15-50
15-30
15-30
10-70
10-100
10-100
10-60
15-20
15-30
10-60
15-20
15-30
15-70
15-100
15-100
15-70
15-100
15-100
15-30
15-30
15-20
15-40
15-50
15-30
15-30
15-40
15-50
15-30
15-30

1
2
2, 3
1
2
2, 3
1
2
3
1
2
3
1
2
1
2
1
2
1
2
1
2
2, 3
1
2
2, 3
1
2
3
1
2
3
1
2
1
2
1
2
1
2
1
2
2, 3, 4
1, 2
1, 2
2, 3
1, 2
1, 2
2, 3
1
2
2, 3
1
2
3
1
2
3
1
2
1
2
1
2
1
2

120/240
120/240
240
120/240
120/240
240
120/240
120/240
240
120/240
120/240
240
120
120/240
120
120/240
120
120/240
120
120/240
120/240
120/240
240
120/240
120/240
240
120/240
120/240
240
120/240
120/240
240
120
120/240
120
120/240
120
120/240
120
120/240
120/240
120/240
240
120/240
120/240
240
120/240
120/240
240
120/240
120/240
240
120/240
120/240
240
120/240
120/240
240
120
120/240
120
120/240
120
120/240
120
120/240

24, 48, 62.5
24, 48, 80
–
24, 48, 62.5
24, 48, 80
–
24, 48, 62.5
24, 48, 80
–
24, 48, 62.5
24, 48, 80
–
–
–
–
–
–
–
–
–
24, 48, 62.5
24, 48, 80
–
24, 48, 62.5
24, 48, 80
–
24, 48, 62.5
24, 48, 80
–
24, 48, 62.5
24, 48, 80
–
–
–
–
–
–
–
–
–
24, 48, 62.5
24, 48, 80
–
24, 48, 62.5
24, 48, 62.5
24, 48, 62.5
24, 48, 62.5
24, 48, 62.5
24, 48, 62.5
24, 48, 62.5
24, 48, 80
–
24, 48, 62.5
24, 48, 80
–
24, 48, 62.5
24, 48, 80
–
–
–
–
–
–
–
–
–

10a, 11a, 12a
10a, 12a
10b, 11b, 12b
14a
14a
14b
–
–
–
15a
15a
15b
10a, 11a, 12a
10a, 11a, 12a
10a, 11a, 12a
10a, 11a, 12a
–
–
–
–
10a, 11a, 12a
10a, 12a
10b, 11b, 12b
14a
14a
14b
–
–
–
15a
15a
15b
10a, 11a, 12a
10a, 11a, 12a
10a, 11a, 12a
10a, 11a, 12a
–
–
–
–
10a, 11a, 12a
10a, 12a
10b, 11b, 12b
–
–
–
–
–
–
14a
14a
14b
–
–
–
15a
15a
15b
–
–
–
–
–
–
–
–

–
–
–
–
–
–
–
–
–
–
–
–
10,000
–
22,000
–
10,000
–
22,000
22,000
–
–
–
–
–
–
–
–
–
–
–
–
10,000
–
22,000
–
10,000
–
22,000
22,000
–
–
–
10,000
22,000
–
10,000
22,000
–
–
–
–
–
–
–
–
–
–
10,000
–
22,000
–
10,000
–
22,000
–

10,000
10,000
–
22,000
22,000
–
42,000
42,000
–
65,000
65,000
–
–
10,000
–
22,000
–
10,000
–
22,000
10,000
10,000
–
22,000
22,000
–
42,000
42,000
–
65,000
65,000
–
–
10,000
–
22,000
–
10,000
–
22,000
10,000
10,000
–
10,000
–
10,000
10,000
–
10,000
22,000
22,000
–
42,000
42,000
–
65,000
65,000
–
–
10,000
–
22,000
–
10,000
–
22,000

–
–
10,000
–
–
22,000
–
–
42,000
–
–
65,000
–
–
–
–
–
–
–
–
–
–
10,000
–
–
22,000
–
–
42,000
–
–
65,000
–
–
–
–
–
–
–
–
–
–
10,000
–
–
–
–
–
–
–
–
22,000
–
–
42,000
–
–
65,000
–
–
–
–
–
–
–
–

5,000
5,000
–
5,000
5,000
–
5,000
5,000
–
5,000
5,000
–
–
–
–
–
–
–
–
–
5,000
5,000
–
5,000
5,000
–
5,000
5,000
–
5,000
5,000
–
–
–
–
–
–
–
–
–
5,000
5,000
–
3,000
3,000
3,000
3,000
3,000
3,000
5,000
5,000
–
5,000
5,000
–
5,000
5,000
–
–
–
–
–
–
–
–
–

➂
5,000
–
➂
5,000
–
➂
5,000
–
➂
5,000
–
–
–
–
–
–
–
–
–
➂
5,000
–
➂
5,000
–
➂
5,000
–
➂
5,000
–
–
–
–
–
–
–
–
–
➂
5,000
–
➂
3,000
3,000
2,000
3,000
3,000
➂
5,000
–
➂
5,000
–
➂
5,000
–
–
–
–
–
–
–
–
–

–
5,000
–
–
5,000
–
–
5,000
–
–
5,000
–
–
–
–
–
–
–
–
–
–
5,000
–
–
5,000
–
–
5,000
–
–
5,000
–
–
–
–
–
–
–
–
–
–
5,000
–
–
–
–
–
–
–
–
5,000
–
–
5,000
–
–
5,000
–
–
–
–
–
–
–
–
–

5
5
5
5
5
5
5
5
5
5
5
5
6
6
6
6
6
6
6
6
7
7
7
7
7
7
7
7
7
7
7
7
8
8
8
8
8
8
8
8
9
9
9
10
10
10
10
10
10
9
9
9
9
9
9
9
9
9
13
13
13
13
13
13
13
13

Circuit Breaker Type Codes: P Plug-in; B Bolt-on; C Cable-in/Cable-out; GF Ground Fault, 5 ma; GFEP Ground Fault, 30 ma.
For Types SPCL and SPHM Supplementary Protectors, see pages 20 and 23.
For Types GHBS and GBHS Solenoid-operated, Remote-controlled Circuit Breakers, see page 14.
➀ QUICKLAG circuit breakers are suitable for
application in relative humidity 0-95% noncondensating.

➁ Two-pole dc interrupting ratings based on
2 poles connected in series.

➂ 62.5 Vac interrupting rating is 3800 AIC 10-50
amperes and 2500 AIC 55-100 amperes
continuous.

PG.74A.01.T.E

Cutler-Hammer

Molded Case Circuit Breakers
Selection Guide

March 1999

Circuit
Breaker
Type

Cont.
Amp
Rating
At 40°C

No.
Poles

Volts
Ac

Dc

Type
of
Trip➀

Federal
Spec.
W-C-375b

3

UL Listed Interrupting Ratings rms Symmetrical Amperes
Ac Ratings Volts
120

120/240

Page
Number

Dc➁
240

277

480

600

125

250

125/250

Series C® Industrial Circuit Breakers
G-Frame
GB
GB

15-100 1
15-100 2, 3

GHB
GHB
GHB
GHB

15-100
15-100
15-100
15-100

GC
GC

15-100 1
15-100 2, 3

GHC
GHC
GHC
GHC

15-100
15-100
15-100
15-100

1
2, 3
1
2, 3

1
2, 3
1
2, 3

120
240

120
240
277
277/480

120
240

120
240
277
277/480

N.I.T.

11a
10b, 11b,
12b, 14b,
15b

65,000
–

–
–

–
65,000

–
–

–
–

–
–

14,000
–

–
–

–
14,000

27
27

125
125/250
125
125/250

N.I.T.

11a
10b, 11b,
12b, 14b,
15b
12c, 13a
13b

65,000
–
–
–

–
–
–
–

–
65,000
–
–

–
–
14,000
14,000

–
–
–
14,000

–
–
–
–

14,000
–
14,000
–

–
–
–
–

–
14,000
–
14,000

27
27
27
27

125
125/250

N.I.T.

11a
10b, 11b,
12b, 14b,
15b

65,000
–

–
–

–
65,000

–
–

–
–

–
–

14,000
–

–
–

–
14,000

28
28

125
125/250
125
125/250

N.I.T.

12c, 13a
13b
12c, 13a
13b

65,000
–
–
–

–
–
–
–

–
65,000
–
–

–
–
14,000
14,000

–
–
–
14,000

–
–
–
–

14,000
–
14,000
–

–
–
–
–

–
14,000
–
14,000

28
28
28
28

125
125/250

F-Frame
GD

15-100 3

480

250

N.I.T.

13b

–

–

65,000

–

22,000

–

10,000

–

26

ED
EDH
EDC

100-255 2, 3
100-255 2, 3
100-255 2, 3

240
240
240

125
125
125

N.I.T.

12b
14b
1

–
–
–

–
–
–

65,000
100,000
200,000

–
–
–

–
–
–

–
–
–

10,000
10,000
10,000

–

–
–
–

–
–
–

32
32
32

EHD
EHD

15-100 1
15-100 2, 3

277
480

125
250

N.I.T.

13a
13b

–
–

–
–

–
18,000

14,000
–

–
14,000

–
–

10,000
–

–
10,000

–
–

32
32

FDB
FDB

15-150 2, 3
15-150 4

600
600

250
250

N.I.T.

18a
➂

–
–

–
–

18,000
18,000

–
–

14,000
14,000

14,000
14,000

10,000
10,000

–
–

32
32

FD
FD
FD

15-150 1
15-150 2, 3
15-150 4

277
600
600

125
250
250

N.I.T.

13a
22a
➂

–
–
–

–
–
–

–
65,000
65,000

25,000
–
–

–
25,000
25,000

–
18,000
18,000

10,000
–
–

–
10,000
10,000

–
–
–

32
32
32

HFD
HFD
HFD

15-150 1
15-150 2,3
15-150 4

277
600
600

125
250
250

N.I.T.

13a
22a
➂

–
–
–

–
–
–

–
100,000
100,000

65,000
–
–

–
65,000
65,000

–
25,000
25,000

10,000
–
–

–
20,000
20,000

–
–
–

33
33
33

FDC
FDC

15-150 2, 3
15-150 4

600
600

250
250

N.I.T.

24a
➂

–
–

–
–

200,000
200,000

–
–

100,000
100,000

35,000
35,000

–
–

20,000
20,000

–
–

33
33

70-250
70-250
70-250
70-250

600
600
600
600

250
250
250
250

N.I.T.
I.T
I.T
I.T

22a
22a
22a
22a

–
–
–
–

–
–
–
–

65,000
65,000
100,000
200,000

–
–
–
–

25,000
25,000
65,000
100,000

18,000
18,000
25,000
35,000

–
–
–
–

10,000
10,000
22,000
22,000

–
–
–
–

39
38
38
38

–
–

J-Frame
JDB
JD
HJD
JDC

2, 3
2, 3, 4
2, 3, 4
2, 3, 4

K-Frame
DK

250-400 2, 3

240

250

N.I.T.

14b

–

–

65,000

–

–

–

–

10,000

–

47

KDB
KD
CKD
HKD
CHKD
KDC

100-400
100-400
100-400
100-400
100-400
100-400

2, 3
2, 3, 4
2, 3, 4
2, 3, 4
2, 3, 4
2, 3, 4

600
600
600
600
600
600

250
250
250
250
250
250

N.I.T.
I.T
I.T
I.T
I.T
I.T

23a
23a
23a
23a
23a
23a

–
–
–
–
–
–

–
–
–
–
–
–

65,000
65,000
65,000
100,000
100,000
200,000

–
–
–
–
–
–

35,000
35,000
35,000
65,000
65,000
100,000

25,000
25,000
25,000
35,000
35,000
50,000

–
–
–
–
–
–

10,000
10,000
10,000
22,000
22,000
22,000

–
–
–
–
–
–

47
45, 46, 49
48, 50
45, 46, 49
48, 50
45, 46, 49

300-600
300-600
300-600
300-600
300-600
300-600
300-600

2, 3
2, 3, 4
2, 3, 4
2, 3, 4
2, 3, 4
2, 3, 4
2, 3, 4

600
600
600
600
600
600
600

250
250
250
250
250
250
250

N.I.T.
I.T
I.T
I.T
I.T
I.T
I.T

23a
23a
23a
23a
23a
23a
23a

–
–
–
–
–
–
–

–
–
–
–
–
–
–

65,000
65,000
65,000
100,000
100,000
200,000
200,000

–
–
–
–
–
–
–

35,000
35,000
35,000
65,000
65,000
100,000
100,000

25,000
25,000
25,000
35,000
35,000
50,000
50,000

–
–
–
–
–
–
–

22,000
22,000
22,000
25,000
25,000
25,000
25,000

–
–
–
–
–
–
–

58
57, 59
58, 61
57, 59
61
57, 60
62

L-Frame
LDB
LD
CLD
HLD
CHLD
LDC
CLDC

➀ N.I.T. is non-interchangeable trip unit and
I.T. is interchangeable trip unit.

PG.74A.01.T.E

➁ Two-pole circuit breaker, or two poles of
three-pole circuit breaker at 250 Vdc.
➂ Not defined in W-C-375b.

Cutler-Hammer

Molded Case Circuit Breaker
Standards

4

March 1999

Selection Guide, Continued
Circuit
Breaker
Type

Cont.
Amp
Rating
At 40°C

No.
Poles

Volts
Ac

Type
of
Trip➀

Dc

Federal
Spec.
W-C-375b

UL Listed Interrupting Ratings rms Symmetrical Amperes
Ac Ratings Volts
120

120/240

Page
Number

Dc➁
240

277

480

600

125

250

125/250

Series C® Industrial Circuit Breakers
M-Frame
MDL
CMDL
HMDL
CHMDL

300-800
300-800
300-800
300-800

2, 3
2, 3
2, 3
2, 3

600
600
600
600

250
250
250
250

I.T.
I.T.
I.T.
I.T.

23a
23a
23a
23a

–
–
–
–

–
–
–
–

65,000
65,000
100,000
100,000

–
–
–
–

50,000
50,000
65,000
65,000

25,000
25,000
35,000
35,000

–
–
–
–

22,000
22,000
25,000
25,000

–
–
–
–

69, 70
70
69, 70
70

600-1200
600-1200
600-1200
600-1200
600-1200
600-1200

3, 4
3, 4
3, 4
3, 4
3, 4
3, 4

600
600
600
600
600
600

–
–
–
–
–
–

N.I.T.
N.I.T.
N.I.T.
N.I.T.
N.I.T.
N.I.T.

23A
23A
23A
23A
23A
23A

–
–
–
–
–
–

–
–
–
–
–
–

65,000
65,000
100,000
100,000
200,000
200,000

–
–
–
–
–
–

50,000
50,000
65,000
65,000
100,000
100,000

25,000
25,000
35,000
35,000
50,000
50,000

–
–
–
–
–
–

–
–
–
–
–
–

–
–
–
–
–
–

77, 83
80, 84
78, 83
81, 84
79, 83
82, 84

800-1600
800-1600
1000-2000
1000-2500
1000-2000
800-1600
800-1600
1000-2000
1000-2500
1000-2000

3, 4
3, 4
3, 4
3, 4
3, 4
3, 4
3, 4
3, 4
3, 4
3, 4

600
600
600
600
600
600
600
600
600
600

–
–
–
–
–
–
–
–
–
–

N.I.T.
N.I.T.
N.I.T.
N.I.T.
N.I.T.
N.I.T.
N.I.T.
N.I.T.
N.I.T.
N.I.T.

24a
24a
24a
24a
24a
25a
25a
25a
25a
25a

–
–
–
–
–
–
–
–
–
–

–
–
–
–
–
–
–
–
–
–

125,000
125,000
125,000
200,000
125,000
200,000
200,000
200,000
200,000
200,000

–
–
–
–
–
–
–
–
–
–

65,000
65,000
65,000
65,000
65,000
100,000
100,000
100,000
100,000
100,000

50,000
50,000
50,000
50,000
50,000
65,000
65,000
65,000
65,000
65,000

–
–
–
–
–
–
–
–
–
–

–
–
–
–
–
–
–
–
–
–

–
–
–
–
–
–
–
–
–
–

91
93
91
91
93
92
93
92
92
93

N-Frame
ND
CND
HND
CHND
NDC
CNDC
R-Frame
RD 1600
CRD 1600
RD 2000
RD 2500
CRD 2000
RDC 1600
CRDC 1600
RDC 2000
RDC 2500
CRDC 2000

Series C HMCP Motor Circuit Protectors

107

Current Limit R Current Limiting Circuit Breakers – Non-Fused Type
FCL

15-100

2, 3

480

–

N.I.T.

–

–

–

200,000

–

150,000

–

–

–

115

LCL

125-400

2, 3

600

–

N.I.T.

–

–

–

200,000

–

200,000 100,000

–

–

–

–

116

Tri-Pac Current Limiting Circuit Breakers – Fused Type
FB

15-100

2, 3

600

250

N.I.T.

16a, 16b,
17a, 26a

–

–

200,000

–

200,000 200,000

–

–

100,000

117

LA

70-400

2, 3

600

250

I.T.

16a, 16b,
17a, 26a

–

–

200,000

–

200,000 200,000

–

–

100,000

118

NB

300-800

2, 3

600

250

I.T.

16b, 17a,
26a

–

–

200,000

–

200,000 200,000

–

–

100,000

119

PB

600-1600

2, 3

600

250

I.T.

17a, 26a

–

–

200,000

–

200,000 200,000

–

–

100,000

120

➀ N.I.T. is non-interchangeable trip unit and
I.T. is interchangeable trip unit.
➁ Two-pole circuit breaker, or two poles of
three-pole circuit breaker at 250 Vdc.

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

Cutler-Hammer

Miniature Circuit Breakers
QUICKLAG Industrial Circuit Breakers

March 1999

5

QUICKLAG Industrial Circuit Breakers Plug-on

Description
Built and Listed to UL 489
QUICKLAG Circuit Breakers
Plug-on Type
Type HQP: 10-150 Amperes,
10,000 AIC
Type QPHW: 15-125 Amperes,
22,000 AIC
Type QHPX: 15-100 Amperes,
42,000 AIC
Type QHPW: 15-30 Amperes,
65,000 AIC

Breaker Catalog Numbers
Continuous Ampere
Rating at
40°C

Catalog Number
1-Pole➀➁

2-Pole➀➁

120/240 Vac

120/240 Vac

3-Pole➀➁
240 Vac

240 Vac

QUICKLAG Type: HQP 10,000 Ampere I.C. Thermal-Magnetic Breakers
HQP1010
HQP1015➂➃
HQP1020➂➃
HQP1025
HQP1030
HQP1035
HQP1040
HQP1045
HQP1050
HQP1055
HQP1060
HQP1070
–
–
HQP1100
–
–
–

10
15
20
25
30
35
40
45
50
55
60
70
80
90
100
110
125
150

HQP2010H
HQP2015H
HQP2020H
HQP2025H
HQP2030H
HQP2035H
HQP2040H
HQP2045H
HQP2050H
HQP2055H
HQP2060H
HQP2070H
HQP2080H
HQP2090H
HQP2100H
–
–
–

HQP2010
HQP2015
HQP2020
HQP2025
HQP2030
HQP2035
HQP2040
HQP2045
HQP2050
HQP2055
HQP2060
HQP2070
HQP2080
HQP2090
HQP2100
HQP2110
HQP2125
HQP2150

HQP3010H
HQP3015H
HQP3020H
HQP3025H
HQP3030H
HQP3035H
HQP3040H
HQP3045H
HQP3050H
HQP3055H
HQP3060H
HQP3070H
HQP3080H
HQP3090H
HQP3100H
–
–
–

QUICKLAG Type: QPHW 22,000 Ampere I.C. Thermal-Magnetic Breakers
QPHW1015➂
QPHW1020➂
QPHW1025
QPHW1030
QPHW1035
QPHW1040
QPHW1045
QPHW1050
QPHW1055
QPHW1060
QPHW1070
–
–
–
–
–

15
20
25
30
35
40
45
50
55
60
70
80
90
100
110
125

QUICKLAG Type HQP 1-Pole

QPHW2015
QPHW2020
QPHW2025
QPHW2030
QPHW2035
QPHW2040
QPHW2045
QPHW2050
QPHW2055
QPHW2060
QPHW2070
QPHW2080
QPHW2090
QPHW2100
QPHW2110
QPHW2125

QPHW2015H
QPHW2020H
QPHW2025H
QPHW2030H
QPHW2035H
QPHW2040H
QPHW2045H
QPHW2050H
QPHW2055H
QPHW2060H
QPHW2070H
QPHW2080H
QPHW2090H
QPHW2100H
–
–

QPHW3015H
QPHW3020H
QPHW3025H
QPHW3030H
QPHW3035H
QPHW3040H
QPHW3045H
QPHW3050H
QPHW3055H
QPHW3060H
QPHW3070H
QPHW3080H
QPHW3090H
QPHW3100H
–
–

QUICKLAG Type: QHPX 42,000 Ampere I.C. Thermal-Magnetic Breakers
QHPX1015➂
QHPX1020➂
QHPX1025
QHPX1030
QHPX1035
QHPX1040
QHPX1045
QHPX1050
QHPX1055
QHPX1060
QHPX1070
–
–
–

15
20
25
30
35
40
45
50
55
60
70
80
90
100

QUICKLAG Type HQP 2-Pole

QHPX2015
QHPX2020
QHPX2025
QHPX2030
QHPX2035
QHPX2040
QHPX2045
QHPX2050
QHPX2055
QHPX2060
QHPX2070
QHPX2080
QHPX2090
QHPX2100

–
–
–
–
–
–
–
–
–
–
–
–
–
–

QHPX3015H
QHPX3020H
QHPX3025H
QHPX3030H
QHPX3035H
QHPX3040H
QHPX3045H
QHPX3050H
QHPX3055H
QHPX3060H
QHPX3070H
QHPX3080H
QHPX3090H
QHPX3100H

–
–
–
–

QHPW3015H
QHPW3020H
–
–

QUICKLAG Type: QHPW 65,000 Ampere I.C. Thermal-Magnetic Breakers
QHPW1015➂
QHPW1020➂
QHPW1025
QHPW1030

15
20
25
30

QHPW2015
QHPW2020
QHPW2025
QHPW2030

QUICKLAG Type HQP 3-Pole

Shipping Data
Poles

➀ All products UL and CSA listed.
➁ All products 15-100A are HACR rated.
➂ Switching duty rated for 120 Vac
fluorescent light applications.
➃ For special low-magnetic breaker order
HQP1015L1 or HQP1020L1

PG.74A.01.T.E

1
2
3

Carton
Quantity

Approximate
Weight Lbs. (Kgs)

24
12
8

9.000 (4.09)
9.000 (4.09)
9.000 (4.09)

Dimensions
Inches (mm)

12.500 (317.50) x 7.500 (190.50) x 5.000 (127.00)
12.500 (317.50) x 7.500 (190.50) x 5.000 (127.00)
12.500 (317.50) x 7.500 (190.50) x 5.000 (127.00)

Time/Current Curves, Dimension Sheets, Application Data

Cutler-Hammer

Miniature Circuit Breakers
QUICKLAG Industrial Circuit Breakers

6

March 1999

QUICKLAG Industrial Ground Fault Circuit Breakers and Equipment Protectors Plug-on

Description

Breaker Catalog Numbers

Plug-on Type
Built and Listed to UL 489
QUICKLAG Ground Fault Circuit
Breakers, Class A GFCI
Built and Tested to UL 943
5mA Trip Sensitivity
Type QPGF: 15-50 Amperes,
10,000 AIC
Type QPHGF: 15-30 Amperes,
22,000 AIC
QUICKLAG Ground Fault Equipment
Protectors
Built and Listed to UL 1053
30mA Trip Sensitivity
Type QPGFEP: 15-50 Amperes,
10,000 AIC
Type QPHGFEP: 15-30 Amperes,
22,000 AIC

Catalog Number

Continuous
Ampere
Rating at
40°C

1-Pole

2-Pole

120 Vac

120/240 Vac

Ground Fault Circuit Breakers – 5mA Sensitivity
QUICKLAG Type: QPGF 10,000 Ampere I.C. Thermal-Magnetic Breakers
QPGF2015
QPGF2020
QPGF2025
QPGF2030
QPGF2040
QPGF2050

QPGF1015
QPGF1020
QPGF1025
QPGF1030
QPGF1040
–

15
20
25
30
40
50

QUICKLAG Type: QPHGF 22,000 Ampere I.C. Thermal-Magnetic Breakers
15
20
25
30

QPHGF1015
QPHGF1020
QPHGF1025
QPHGF1030

QPHGF2015
QPHGF2020
QPHGF2025
QPHGF2030

Ground Fault Equipment Protectors – 30mA Sensitivity
QUICKLAG Type: QPGFEP 10,000 Ampere I.C. Thermal-Magnetic Breakers
QPGFEP2015
QPGFEP2020
QPGFEP2025
QPGFEP2030
QPGFEP2040
QPGFEP2050

QPGFEP1015
QPGFEP1020
QPGFEP1025
QPGFEP1030
QPGFEP1040
–

15
20
25
30
40
50

QUICKLAG Type: QPHGFEP 22,000 Ampere I.C. Thermal-Magnetic Breakers
QPHGFEP2015
QPHGFEP2020
QPHGHEP2025
QPHGFEP2030

QPHGFEP1015
QPHGFEP1020
QPHGFEP1025
QPHGFEP1030

15
20
25
30

Special Application Ground Fault Circuit Protectors – 5mA Sensitivity
QUICKLAG Type: QPGF 10,000 Ampere I.C. with Bell Alarm (W1) or Auxiliary Switch (W2)

QUICKLAG Type QPGF 1-Pole
Ground Fault Circuit Breaker

15
20
25
30
40
50

QPGF1015W1
QPGF1020W1
QPGF1025W1
QPGF1030W1
–
–

QPGF2015W1
QPGF2020W1
QPGF2025W1
QPGF2030W1
QPGF2040W1
QPGF2050W1

15
20
25
30

QPGF1015W2
QPGF1020W2
QPGF1025W2
QPGF1030W2

–
–
–
–

Special Application Ground Fault Circuit Protectors – 30mA Sensitivity
QUICKLAG Type: QPGFEP 10,000 Ampere I.C. with Bell Alarm (W1) or Auxiliary Switch (W2)

QUICKLAG Type QPGF 2-Pole
Ground Fault Circuit Breaker

Shipping Data
Shipped individually or in carton
quantities.
Poles Carton Approximate
Dimensions
Quantity Weight Lbs. (Kgs) Inches (mm)

1

20

11.000 (4.99)

2

5

5.000 (2.29)

12.500 (317.50) x
6.500 (165.10) x
5.000 (127.00)
15.500 (393.70) x
6.000 (152.40) x
4.500 (114.30)

15
20
25
30
40
50

QPGFEP1015W1
QPGFEP1020W1
QPGFEP1025W1
QPGFEP1030W1
–
–

QPGFEP2015W1
QPGFEP2020W1
QPGFEP2025W1
QPGFEP2030W1
QPGFEP2040W1
QPGFEP2050W1

15
20
25
30

QPGFEP1015W2
QPGFEP1020W2
QPGFEP1025W2
QPGFEP1030W2

–
–
–
–

Bell Alarm and Auxiliary Contact Schematic
Blue
Ground
Fault
Breaker

Blue Wire
NC

Red

Black Wire

NO
Red Wire

Single-throw double-pole contacts are UL and CSA listed for 5 Amperes at 250 Vac.
Bell Alarm (W1) – contacts change state when breaker trips.
Auxiliary Switch (W2) – contacts change state when breaker is opened (or tripped) or closed.
14-inch long #18 AWG pigtail wire leads provided.

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

Cutler-Hammer

Miniature Circuit Breakers
QUICKLAG Industrial Circuit Breakers

March 1999

7

QUICKLAG Industrial Circuit Breakers Bolt-on

Description
Built and Listed to UL 489
QUICKLAG Circuit Breakers
Bolt-on Type
Type BA: 10-125 Amperes,
10,000 AIC
Type QBHW: 15-125 Amperes,
22,000 AIC
Type HBAX: 15-100 Amperes,
42,000 AIC
Type HBAW: 15-30 Amperes,
65,000 AIC

Breaker Catalog Numbers
Catalog Number

Continuous
Ampere
Rating at
40°C

1-Pole➀➁

2-Pole➀➁

120/240 Vac

120/240 Vac

3-Pole➀➁
240 Vac

240 Vac

QUICKLAG Type: BA 10,000 Ampere I.C. Thermal-Magnetic Breakers

10
15
20
25
30
35
40
45
50
55
60
70
80
90
100
110
125

BAB1010
BAB1015➂➃
BAB1020➂➃
BAB1025
BAB1030
BAB1035
BAB1040
BAB1045
BAB1050
BAB1055
BAB1060
BAB1070
–
–
BAB1100
–
–

BAB2010H
BAB2015H
BAB2020H
BAB2025H
BAB2030H
BAB2035H
BAB2040H
BAB2045H
BAB2050H
BAB2055H
BAB2060H
BAB2070H
BAB2080H
BAB2090H
BAB2100H
–
–

BAB2010
BAB2015
BAB2020
BAB2025
BAB2030
BAB2035
BAB2040
BAB2045
BAB2050
BAB2055
BAB2060
BAB2070
BAB2080
BAB2090
BAB2100
BAB2110
BAB2125

BAB3010H
BAB3015H
BAB3020H
BAB3025H
BAB3030H
BAB3035H
BAB3040H
BAB3045H
BAB3050H
BAB3055H
BAB3060H
BAB3070H
BAB3080H
BAB3090H
BAB3100H
–
–

QUICKLAG Type: QBHW 22,000 Ampere I.C. Thermal-Magnetic Breakers
15
20
25
30
35
40
45
50
55
60
70
80
90
100
110
125

QUICKLAG Type BA 1-Pole

QBHW1015➂
QBHW1020➂
QBHW1025
QBHW1030
QBHW1035
QBHW1040
QBHW1045
QBHW1050
QBHW1055
QBHW1060
QBHW1070
–
–
–
–
–

QBHW2015
QBHW2020
QBHW2025
QBHW2030
QBHW2035
QBHW2040
QBHW2045
QBHW2050
QBHW2055
QBHW2060
QBHW2070
QBHW2080
QBHW2090
QBHW2100
QBHW2110
QBHW2125

QBHW2015H
QBHW2020H
QBHW2025H
QBHW2030H
QBHW2035H
QBHW2040H
QBHW2045H
QBHW2050H
QBHW2055H
QBHW2060H
QBHW2070H
QBHW2080H
QBHW2090H
QBHW2100H
–
–

QBHW3015H
QBHW3020H
QBHW3025H
QBHW3030H
QBHW3035H
QBHW3040H
QBHW3045H
QBHW3050H
QBHW3055H
QBHW3060H
QBHW3070H
QBHW3080H
QBHW3090H
QBHW3100H
–
–

QUICKLAG Type: HBAX 42,000 Ampere I.C. Thermal-Magnetic Breakers
15
20
25
30
35
40
45
50
55
60
70
80
90
100

QUICKLAG Type BA 2-Pole

HBAX1015➂
HBAX1020➂
HBAX1025
HBAX1030
HBAX1035
HBAX1040
HBAX1045
HBAX1050
HBAX1055
HBAX1060
HBAX1070
–
–
–

HBAX2015
HBAX2020
HBAX2025
HBAX2030
HBAX2035
HBAX2040
HBAX2045
HBAX2050
HBAX2055
HBAX2060
HBAX2070
HBAX2080
HBAX2090
HBAX2100

–
–
–
–
–
–
–
–
–
–
–
–
–
–

HBAX3015H
HBAX3020H
HBAX3025H
HBAX3030H
HBAX3035H
HBAX3040H
HBAX3045H
HBAX3050H
HBAX3055H
HBAX3060H
HBAX3070H
HBAX3080H
HBAX3090H
HBAX3100H

–
–
–
–

HBAW3015H
HBAW3020H
–
–

QUICKLAG Type: HBAW 65,000 Ampere I.C. Thermal-Magnetic Breakers
15
20
25
30

QUICKLAG Type BA 3-Pole

PG.74A.01.T.E

HBAW2015
HBAW2020
HBAW2025
HBAW2030

Shipping Data
Poles

➀ All products UL and CSA listed.
➁ All products 15-100A are HACR rated.
➂ Switching duty rated for 120 Vac
fluorescent light applications.
➃ For special low-magnetic breaker order
BAB1015L1 or BAB1020L1.

HBAW1015➂
HBAW1020➂
HBAW1025
HBAW1030

1
2
3

Carton
Quantity

24
18
8

Approximate
Weight Lbs. (Kgs)

9.000 (4.09)
9.000 (4.09)
9.000 (4.09)

Dimensions Inches (mm)

12.500 (317.50) x 7.500 (190.50) x 5.000 (127.00)
12.500 (317.50) x 7.500 (190.50) x 5.000 (127.00)
12.500 (317.50) x 7.500 (190.50) x 5.000 (127.00)

Time/Current Curves, Dimension Sheets, Application Data

Cutler-Hammer

Miniature Circuit Breakers
QUICKLAG Industrial Circuit Breakers

8

March 1999

QUICKLAG Industrial Ground Fault Circuit Protectors Bolt-on

Description

Breaker Catalog Numbers

Bolt-on Type
Built and Listed to UL 489
QUICKLAG Ground Fault Circuit
Breakers, Class A GFCI
Built and Tested to UL 943
5mA Trip Sensitivity
Type QBGF: 15-50 Amperes,
10,000 AIC
Type QBHGF: 15-30 Amperes,
22,000 AIC
QUICKLAG Ground Fault
Equipment Protectors
Built and Tested to UL 1053
30mA Trip Sensitivity
Type QBGFEP: 15-50 Amperes,
10,000 AIC
Type QBHGFEP: 15-30 Amperes,
22,000 AIC

Continuous
Ampere
Rating at
40°C

Catalog Number
1-Pole

2-Pole

120 Vac

120/240 Vac

Ground Fault Circuit Breakers – 5mA Sensitivity
QUICKLAG Type: QBGF 10,000 Ampere I.C. Thermal-Magnetic Breakers
QBGF2015
QBGF2020
QBGF2025
QBGF2030
QBGF2040
QBGF2050

QBGF1015
QBGF1020
QBGF1025
QBGF1030
QBGF1040
–

15
20
25
30
40
50

QUICKLAG Type: QBHGF 22,000 Ampere I.C. Thermal-Magnetic Breakers
QBHGF2015
QBHGF2020
QBHGF2025
QBHGF2030

QBHGF1015
QBHGF1020
QBHGF1025
QBHGF1030

15
20
25
30

Ground Fault Equipment Protectors – 30mA Sensitivity
QUICKLAG Type: QBGFEP 10,000 Ampere I.C. Thermal-Magnetic Breakers
QBGFEP2015
QBGFEP2020
QBGFEP2025
QBGFEP2030
QBGFEP2040
QBGFEP2050

QBGFEP1015
QBGFEP1020
QBGFEP1025
QBGFEP1030
QBGFEP1040
–

15
20
25
30
40
50

QUICKLAG Type: QBHGFEP 22,000 Ampere I.C. Thermal-Magnetic Breakers
QBHGFEP2015
QBHGFEP2020
QBHGFEP2025
QBHGFEP2030

QBHGFEP1015
QBHGFEP1020
QBHGFEP1025
QBHGFEP1030

15
20
25
30

Special Application Ground Fault Circuit Protectors – 5mA Sensitivity
QUICKLAG Type: QBGF 10,000 Ampere I.C. with Bell Alarm (W1) or Auxiliary Switch (W2)

QUICKLAG Type QBGF 1-Pole
Ground Fault Circuit Breaker

15
20
25
30
40
50

QBGF1015W1
QBGF1020W1
QBGF1025W1
QBGF1030W1
–
–

QBGF2015W1
QBGF2020W1
QBGF2025W1
QBGF2030W1
QBGF2040W1
QBGF2050W1

15
20
25
30

QBGF1015W2
QBGF1020W2
QBGF1025W2
QBGF1030W2

–
–
–
–

Special Application Ground Fault Circuit Protectors – 30mA Sensitivity
QUICKLAG Type: QBGFEP 10,000 Ampere I.C. with Bell Alarm (W1) or Auxiliary Switch (W2)

QUICKLAG Type QBGF 2-Pole
Ground Fault Circuit Breaker

Shipping Data
Poles

1
2

Carton
Quantity

20
5

15
20
25
30
40
50

QBGFEP1015W1
QBGFEP1020W1
QBGFEP1025W1
QBGFEP1030W1
–
–

QBGFEP2015W1
QBGFEP2020W1
QBGFEP2025W1
QBGFEP2030W1
QBGFEP2040W1
QBGFEP2050W1

15
20
25
30

QBGFEP1015W2
QBGFEP1020W2
QBGFEP1025W2
QBGFEP1030W2

–
–
–
–

Bell Alarm and Auxiliary Contact Schematic
Approximate
Weight Lbs.
(Kgs)

11.000 (4.99)
5.000 (2.29)

Dimensions
Inches (mm)

12.500 (317.50)
x 6.500 (165.10)
x 5.000 (127.00)
15.500 (393.70)
x 6.000 (152.40)
x 4.500 (114.30)

Blue
Ground
Fault
Breaker

Blue Wire
NC

Red

Black Wire

NO
Red Wire

Single-throw double-pole contacts are UL and CSA listed for 5 Amperes at 250 Vac.
Bell Alarm (W1) – contacts change state when breaker trips.
Auxiliary Switch (W2) – contacts change state when breaker is opened (or tripped) or closed.
14-inch long #18 AWG pigtail wire leads provided.

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

Cutler-Hammer

Miniature Circuit Breakers
QUICKLAG Industrial Circuit Breakers

March 1999

9

QUICKLAG Industrial Circuit Breakers Cable-in/Cable-out (1 inch per pole)

Description
Built and Listed to UL 489
QUICKLAG Circuit Breakers
Cable-in/Cable-out Type
Type QC: 10-100 Amperes,
10,000 AIC
Type QCHW: 15-100 Amperes,
22,000 AIC
Type QHCX: 15-100 Amperes,
42,000 AIC
Type QHCW: 15-30 Amperes,
65,000 AIC

Breaker Catalog Numbers
Catalog Number

Continuous
Ampere
Rating at
40°C

1-Pole➀➁

2-Pole➀➁

120/240 Vac

120/240 Vac

240 Vac

3-Pole➀➁

4-Pole➀➁

240 Vac

240 Vac

QUICKLAG Type: QC 10,000 Ampere I.C. Thermal-Magnetic Breakers
QC1010
QC1015➂➃
QC1020➂➃
QC1025
QC1030
QC1035
QC1040
QC1045
QC1050
QC1055
QC1060
QC1070
–
–
QC1100

10
15
20
25
30
35
40
45
50
55
60
70
80
90
100

QC2010
QC2015
QC2020
QC2025
QC2030
QC2035
QC2040
QC2045
QC2050
QC2055
QC2060
QC2070
QC2080
QC2090
QC2100

QC2010H
QC2015H
QC2020H
QC2025H
QC2030H
QC2035H
QC2040H
QC2045H
QC2050H
QC2055H
QC2060H
QC2070H
QC2080H
QC2090H
QC2100H

QC3010H
QC3015H
QC3020H
QC3025H
QC3030H
QC3035H
QC3040H
QC3045H
QC3050H
QC3055H
QC3060H
QC3070H
QC3080H
QC3090H
QC3100H

QC4010H
QC4015H
QC4020H
QC4025H
QC4030H
QC4035H
QC4040H
QC4045H
QC4050H
QC4055H
QC4060H
QC4070H
QC4080H
QC4090H
QC4100H

QUICKLAG Type: QCHW 22,000 Ampere I.C. Thermal-Magnetic Breakers

QCHW1015➂
QCHW1020➂
QCHW1025
QCHW1030
QCHW1035
QCHW1040
QCHW1045
QCHW1050
QCHW1055
QCHW1060
QCHW1070
–
–
–

15
20
25
30
35
40
45
50
55
60
70
80
90
100

QUICKLAG Type QC 1-Pole

QCHW2015
QCHW2020
QCHW2025
QCHW2030
QCHW2035
QCHW2040
QCHW2045
QCHW2050
QCHW2055
QCHW2060
QCHW2070
QCHW2080
QCHW2090
QCHW2100

QCHW2015H
QCHW2020H
QCHW2025H
QCHW2030H
QCHW2035H
QCHW2040H
QCHW2045H
QCHW2050H
QCHW2055H
QCHW2060H
QCHW2070H
QCHW2080H
QCHW2090H
QCHW2100H

QCHW3015H
QCHW3020H
QCHW3025H
QCHW3030H
QCHW3035H
QCHW3040H
QCHW3045H
QCHW3050H
QCHW3055H
QCHW3060H
QCHW3070H
QCHW3080H
QCHW3090H
QCHW3100H

QCHW4015H
QCHW4020H
QCHW4025H
QCHW4030H
QCHW4035H
QCHW4040H
QCHW4045H
QCHW4050H
QCHW4055H
QCHW4060H
QCHW4070H
QCHW4080H
QCHW4090H
QCHW4100H

QUICKLAG Type: QHCX 42,000 Ampere I.C. Thermal-Magnetic Breakers

QHCX1015➂
QHCX1020➂
QHCX1025
QHCX1030
QHCX1035
QHCX1040
QHCX1045
QHCX1050
QHCX1055
QHCX1060
QHCX1070
–
–
–

15
20
25
30
35
40
45
50
55
60
70
80
90
100

QUICKLAG Type QC 3-Pole

–
–
–
–
–
–
–
–
–
–
–
–
–
–

QHCX2015
QHCX2020
QHCX2025
QHCX2030
QHCX2035
QHCX2040
QHCX2045
QHCX2050
QHCX2055
QHCX2060
QHCX2070
QHCX2080
QHCX2090
QHCX2100

QHCX3015H
QHCX3020H
QHCX3025H
QHCX3030H
QHCX3035H
QHCX3040H
QHCX3045H
QHCX3050H
QHCX3055H
QHCX3060H
QHCX3070H
QHCX3080H
QHCX3090H
QHCX3100H

–
–
–
–
–
–
–
–
–
–
–
–
–
–

QUICKLAG Type: QHCW 65,000 Ampere I.C. Thermal-Magnetic Breakers

QHCW1015➂
QHCW1020➂
QHCW1025
QHCW1030

15
20
25
30

–
–
–
–

QHCW2015
QHCW2020
QHCW2025
QHCW2030

QHCW3015H
QHCW3020H
–
–

Shipping Data
Poles

QUICKLAG Type QC 4-Pole

➀ All products UL and CSA listed.
➁ All products 10-100A are HACR rated.
➂ Switching duty rated for 120 Vac
fluorescent light applications only.
➃ For special low-magnetic breaker order
QC1015L1 or QC1020L1.

PG.74A.01.T.E

1
2
3

Carton
Quantity

24
18
8

Approximate
Weight Lbs. (Kgs)

9.000 (4.09)
9.000 (4.09)
9.000 (4.09)

Dimensions Inches (mm)

12.500 (317.50) x 7.500 (190.50) x 5.000 (127.00)
12.500 (317.50) x 7.500 (190.50) x 5.000 (127.00)
12.500 (317.50) x 7.500 (190.50) x 5.000 (127.00)

–
–
–
–

Cutler-Hammer

Miniature Circuit Breakers
QUICKLAG Industrial Circuit Breakers

10

March 1999

QUICKLAG Industrial Circuit Breakers Cable-in/Cable-out (1/2 inch per pole)

Description
Built and Listed to UL 489
Type QCR and QCF Circuit Breakers
are UL listed Circuit Breakers that
are suitable for use as branch circuit
protectors.

Applications
QCR and QCF Circuit Breakers are
only 1/2-inch wide per pole and
are excellent for general purpose
industrial applications where space
savings is required.

1-Pole

2-Pole

QCR (Rear-Mounted Breakers)

1-Pole

2-Pole

QCF (Front-Mounted Breakers)

Product Features and Ratings
■
■
■
■
■
■
■
■
■
■
■
■
■
■

1/2-inch wide per pole
Cable-in/Cable-out
Black cases with black handles
Three position handle: ON,
Tripped (center), OFF
Thermal-Magnetic Protection
UL File E7819
CSA File LR48907
One, two and three pole
10 kAIC at 120/240 Vac,
10-60 Amperes
22 kAIC at 120/240 Vac,
15-20 Amperes
10 kAIC at 240 Vac, 10-30 Amperes
3 kAIC at 62.5 Vdc (1 Pole)
3 kAIC at 130 Vdc (2 Poles
in Series)
Normal Operating Environment:
0-40°C
5-95% Humidity
(Non-Condensating)

Additional Ratings
In addition to the ratings shown for
the 1/2-inch wide QCR and QCF, the
complete QC breaker line includes:
■
■
■
■
■

3-Pole

3-Pole

QCR (Rear-Mounted Breakers)

QCF (Front-Mounted Breakers)

Type QCR have as a standard feature
provisions for 35mm DIN-Rail rear
mounting with a spring-loaded
release. Optional clips for individual
mounting are available as a separate
accessory.

Type QCF have two threaded steel
inserts to facilitate front mounting
with #6-32 steel screws. The clamp
type terminals accessible from the
rear of the breaker so that cables can
be accessed without removal of the
breaker from the front cover.

QCR 1-Pole Breaker with QCRMTGFT
Clips (Qty. 2) Individually Mounted

QCF Breaker Front Panel Mounted

1-4 Poles
5-100 Amperes
10 through 65 kAIC
120/240 and 240 Vac
1-inch per pole

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

Cutler-Hammer

Miniature Circuit Breakers
QUICKLAG Industrial Circuit Breakers

March 1999

11

QUICKLAG Industrial Circuit Breakers Cable-in/Cable-out (1/2 inch per pole)
Breaker Catalog Numbers➀➁➂➃
Continuous
Ampere
Rating at
40°C

QCR Breaker 10 kAIC Interruption Ratings➄

QCF Breaker 10 kAIC Interruption Ratings➄

120/240 Vac

120/240 Vac

240 Vac➅

1-Pole

2-Pole

2-Pole

3-Pole

QCR Breaker 10 kAIC Interruption Ratings➄

120/240 Vac

120/240 Vac

240 Vac➅

1-Pole

2-Pole

2-Pole

3-Pole

QCF Breaker 10 kAIC Interruption Ratings➄
QCF1010
QCF1010T
–

QCF2010
QCF2010T
–

–
–
–

–
–
–

QCR3015H
QCR3015HT
–

QCF1015➁
QCF1015T➁
–

QCF2015
QCF2015T
–

QCF2015H
QCF2015HT
–

QCF3015H
QCF3015HT
–

QCR2020H
QCR2020HT
–

QCR3020H
QCR3020HT
–

QCF1020➁
QCF1020T➁
–

QCF2020
QCF2020T
–

QCF2020H
QCF2020HT
–

QCF3020H
QCF3020HT
–

QCR2025
QCR2025T
QCR2025P

QCR2025H
QCR2025HT
–

QCR3025H
QCR3025HT
–

QCF1025
QCF1025T
–

QCF2025
QCF2025T
–

QCF2025H
QCF2025HT
–

QCF3025H
QCF3025HT
–

QCR1030
QCR1030T
–

QCR2030
QCR2030T
QCR2030P

QCR2030H
QCR2030HT
–

QCR3030H
QCR3030HT
–

QCF1030
QCF1030T
–

QCF2030
QCF2030T
–

QCF2030H
QCF2030HT
–

QCF3030H
QCF3030HT
–

35

QCR1035
–

QCR2035
QCR2035P

–
–

–
–

QCF1035
–

QCF2035
–

–
–

–
–

40

QCR1040
–

QCR2040
QCR2040P

–
–

–
–

QCF1040
–

QCF2040
–

–
–

–
–

45

QCR1045
–

QCR2045
QCR2045P

–
–

–
–

QCF1045
–

QCF2045
–

–
–

–
–

50

QCR1050
–

QCR2050
QCR2050P

–
–

–
–

QCF1050
–

QCF2050
–

–
–

–
–

55

QCR1055
–

QCR2055
QCR2055P

–
–

–
–

QCF1055
–

QCF2055
–

–
–

–
–

60➇

QCR1060
–

QCR2060
QCR2060P

–
–

–
–

QCF1060
–

QCF2060
–

–
–

–
–

10

QCR1010
QCR1010T
–

QCR2010
QCR2010T
QCR2010P

–
–
–

–
–
–

15

QCR1015➆
QCR1015T➆
–

QCR2015
QCR2015T
QCR2015P

QCR2015H
QCR2015HT
–

20

QCR1020➆
QCR1020T➆
–

QCR2020
QCR2020T
QCR2020P

25

QCR1025
QCR1025T
–

30

QCR Breaker 22 kAIC Interruption Ratings

QCF Breaker 22 kAIC Interruption Ratings

15

QCRH1015➆
QCRH1015T➆

QCRH2015
QCRH2015T

–
–

–
–

QCFH1015➆
QCFH1015T➆

QCFH2015
QCFH2015T

–
–

–
–

20

QCRH1020➆
QCRH1020T➆

QCRH2020
QCRH2020T

–
–

–
–

QCFH1020➆
QCFH1020T➆

QCFH2020
QCFH2020T

–
–

–
–

Available QCR and QCF Breaker Accessories
Catalog Number

Description

QCRMTGFT

Steel mounting clip mounts QCR breaker if individual mounting is required. Quantity two required for 1- and 2-pole and four required
for 3-pole breakers.

QCRFPL1P

Removable padlock device for single-pole QCR or QCF breaker.

QCRFPLMP

Removable padlock device for multi-pole QCR or QCF breaker.

QCRFLOFF

Padlock bracket assembly for QCR or QCF single or multi-pole breakers (off only).

➀ Standard breaker terminals are box type
lugs.
➁ Breakers with “T” Catalog Number Suffix are
suitable for line and load side ring terminal
connection (#10-32 plus/minus terminal
screw provided).

PG.74A.01.T.E

➂ Breakers with “P” Catalog Number Suffix are
suitable for terminating 2 #10 AWG QuickConnect Type Terminals per phase on
breaker load side.
➃ Breakers with Shunt Trip Attachment (extra
pole required on breaker right-hand side) are
available. Contact Cutler-Hammer.
➄ All ratings 15 to 60 amperes are HACR rated.

➅ Breakers with “H” Catalog Suffix have
240 Vac construction.
➆ All 15 and 20 ampere single-pole breakers
are SWD (Switching Duty) rated for fluorescent lighting applications.
➇ 60/75°C Cu/Al wire on all ratings except 60
amperes which requires Cu only conductor.

12

Miniature Circuit Breakers
QUICKLAG Industrial Circuit Breakers

Cutler-Hammer
March 1999

QUICKLAG Industrial Circuit Breakers Cable-in/Cable-out (1/2 inch per pole)

QCR and QCF Breaker Factory Installed Terminals

QCR and QCF Standard Box Terminals
Factory installed line and load side
breaker terminal to accommodate
#14 AWG to #4 AWG wire.

QCR Quick-Connect Terminals
Factory installed two-prong quickconnect terminal on breaker load
side suitable for terminating two
#10 AWG wire with insulated slip-on
terminals as shown. Line side terminal is the standard type.

QCR and QCF Ring or
Spade Lug Terminals
(10 to 30 ampere ratings only):
Factory installed line and load side
terminals each equipped with a
#10-32 screw suitable for terminating
one #10 AWG wire with insulated
ring or spade type terminal as shown.

Catalog Suffix “P”

Catalog Suffix “T”

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

Cutler-Hammer

Miniature Circuit Breakers
QUICKLAG Industrial Circuit Breakers

March 1999

13

QUICKLAG Industrial Ground Fault Circuit Breakers and Equipment Protectors Cable-in/Cable-out

Description

Breaker Catalog Numbers

Cable-in/Cable-out Type
Built and Listed to UL 489
QUICKLAG Ground Fault
Circuit Breakers, Class A GFCI
Built and Tested to UL 943
5mA Trip Sensitivity
Type QCGF: 15-50 Amperes,
10,000 AIC
Type QCHGF: 15-30 Amperes,
22,000 AIC
QUICKLAG Ground Fault
Equipment Protectors
Built and Tested to UL 1053
30mA Trip Sensitivity
Type QCGFEP: 15-50 Amperes,
10,000 AIC
Type QCHGFEP: 15-30 Amperes,
22,000 AIC

Catalog Number

Continuous
Ampere
Rating at
40°C

1-Pole➀

2-Pole➀

120 Vac

120/240 Vac

Ground Fault Circuit Breakers – 5mA Sensitivity
QUICKLAG Type: QCGF 10,000 Ampere I.C. Thermal-Magnetic Breakers
15
20
25
30
40
50

QCGF2015
QCGF2020
QCGF2025
QCGF2030
QCGF2040
QCGF2050

QCGF1015
QCGF1020
QCGF1025
QCGF1030
QCGF1040
–

QUICKLAG Type: QCHGF 22,000 Ampere I.C. Thermal-Magnetic Breakers
15
20
25
30

QCHGF1015
QCHGF1020
QCHGF1025
QCHGF1030

QCHGF2015
QCHGF2020
QCHGF2025
QCHGF2030

Ground Fault Equipment Protectors – 30mA Sensitivity
QUICKLAG Type: QCGFEP 10,000 Ampere I.C. Thermal-Magnetic Breakers
15
20
25
30
40
50

QCGFEP2015
QCGFEP2020
QCGFEP2025
QCGFEP2030
QCGFEP2040
QCGFEP2050

QCGFEP1015
QCGFEP1020
QCGFEP1025
QCGFEP1030
QCGFEP1040
–

QUICKLAG Type: QCHGFEP 22,000 Ampere I.C. Thermal-Magnetic Breakers
15
20
25
30

QCHGFEP2015
QCHGFEP2020
QCHGFEP2025
QCHGFEP2030

QCHGFEP1015
QCHGFEP1020
QCHGFEP1025
QCHGFEP1030

Special Application Ground Fault Circuit Protector – 5mA Sensitivity
QUICKLAG Type: QCGF 10,000 Ampere I.C. with Bell Alarm (W1) or Auxiliary Switch (W2)

QUICKLAG Type QCGF 1-Pole
Ground Fault Circuit Breaker

15
20
25
30
40
50

QCGF1015W1
QCGF1020W1
QCGF1025W1
QCGF1030W1
–
–

15
20
25
30

QCGF1015W2
QCGF1020W2
QCGF1025W2
QCGF1030W2

QCGF2015W1
QCGF2020W1
QCGF2025W1
QCGF2030W1
QCGF2040W1
QCGF2050W1
–
–
–
–

Special Application Ground Fault Equipment Protectors – 30mA Sensitivity
QUICKLAG Type: QCGFEP 10,000 Ampere I.C. with Bell Alarm (W1) or Auxiliary Switch (W2)

QUICKLAG Type QCGF 2-Pole
Ground Fault Circuit Breaker

1
2

Carton
Approximate
Quantity Weight Lbs.
(Kgs)

20
5

QCGFEP2015W1
QCGFEP2020W1
QCGFEP2025W1
QCGFEP2030W1
QCGFEP2040W1
QCGFEP2050W1

15
20
25
30

QCGFEP1015W2
QCGFEP1020W2
QCGFEP1025W2
QCGFEP1030W2

–
–
–
–

11.000 (4.99)
5.000 (2.29)

Dimensions
Inches (mm)

12.500 (317.50) x
6.500 (165.10) x
5.000 (127.00)
15.500 (393.70) x
6.000 (152.40) x
4.500 (114.30)

➀ All products UL and CSA listed.

PG.74A.01.T.E

QCGFEP1015W1
QCGFEP1020W1
QCGFEP1025W1
QCGFEP1030W1
–
–

Bell Alarm and Auxiliary Contact Schematic

Shipping Data
Poles

15
20
25
30
40
50

Blue
Ground
Fault
Breaker

Blue Wire
NC

Red

Black Wire

NO
Red Wire

Single-throw double-pole contacts are UL and CSA listed for 5 Amperes at 250 Vac.
Bell Alarm (W1) – contacts change state when breaker trips.
Auxiliary Switch (W2) – contacts change state when breaker is opened (or tripped) or closed.
14-inch long #18 AWG pigtail wire leads provided.

Cutler-Hammer

Miniature Circuit Breakers
QUICKLAG Industrial Circuit Breakers

14

March 1999

Types GHBS and GBHS Solenoid-Operated, Remote-Controlled

Description
GHBS and GBHS circuit breakers are
bolt-on branch circuit breakers
designed for use in panelboards and
are ideally suited for lighting control
applications. In addition to providing conventional branch circuit
protection, they include a unique
solenoid-operated mechanism that
provides for efficient breaker pulseon and pulse-off operation when
used with a suitable controller like
the Cutler-Hammer Pow-R-Command lighting control system.

1-Pole

2-Pole

GHBS UL 489 Interrupting Ratings

Product Features
■

Bolt-on Line-Side Terminal

■

Cable Connected Load-Side
Terminal

■

3-Prong Control Terminal (Common, Solenoid, Auxiliary Switch)

■

Bi-Metal Assembly for Thermal
Overload Protection

■

Fast Acting Short Circuit
Protection

■

Arc-Runner and Arc-Chute
Assembly for Fast Acting Arc
Extinction

■

Three Position Handle: OFF, TRIP
(Center), ON

■

Handle in “ON” Position Enables
Remote Control

■

Handle in “OFF” Position Disables
Remote Control

■

Handle Permits Manual Switching When Control Power is Lost

■

Mechanical Trip Indicator Window
(Red-ON, Green-OFF/TRIPPED)

■

15 and 20 Ampere Breakers SWD
(Switching Duty) Rated

■

HID Ratings for HID (High Intensity Discharge) Lighting

■

Auxiliary Switch for Control
Circuit Feedback

Circuit
Breaker
Type➀

Number of Poles

Interrupting Capacity (Symmetrical Amperes)
Rating
Amperes➁

Volts Ac (50/60 Hz)
120

240

277/480

GHBS1015D
GHBS1020D
GHBS1030D

1
1
1

15
20
30

65,000
65,000
65,000

–
–
–

14,000
14,000
14,000

GHBS2015D
GHBS2020D
GHBS2030D

2
2
2

15
20
30

–
–
–

65,000
65,000
65,000

14,000
14,000
14,000

Instruction Leaflet/FRED Number 15546

GBHS CSA 22.2 Interrupting Ratings
Number of
Poles

Circuit
Breaker
Type

Interrupting Capacity (Symmetrical Amperes)
Rating
Amperes➁

Volts Ac (50/60 Hz)
347/600

GBHS1015D
GBHS1020D

1
1

15
20

10,000
10,000

GBHS2015D
GBHS2020D

2
2

15
20

10,000
10,000

15-20 Amperes

30 Amperes

Terminal Type
For load-side. Terminals are UL listed as suitable for wire type and size given below.
Circuit Breaker
Amperes

Terminal
Type

Screw Head
Type

Wire
Type

AWG Wire
Range

15-20

Clamp

Slotted

Cu/Al

#14-#10

30

Box

Slotted

Cu/Al

#14-#2

Dimensions Per Pole, Inches (mm)
Width

Dimensions in parentheses in millimeters.

1.000
(25.40)

Height

4.125
(104.78)

Depth

2.810
(71.37)

➀ All UL listed circuit breakers are HID (High
Intensity Discharge) rated.
➁ Continuous current rating at 40°C.

PG.74A.01.T.E

Cutler-Hammer

Miniature Circuit Breakers
QUICKLAG Industrial Circuit Breakers

March 1999

15

Types GHBS and GBHS Solenoid-Operated, Remote-Controlled
Wiring Diagrams
2-Pole Circuit Breaker

a

Circuit Breaker

Solenoid

Solenoid

Common
AMP Inc.
Conductor
Plug

Conductor
Plug (As
Viewed From
End)

a

Solenoid

a

Solenoid

Auxiliary

Common

/2 Cycle
Maximum
28 Vac
Pulse Source

Solenoid

Auxiliary

1

AMP Inc.
Conductor
Plug

28 Vac
Circuit Breaker
Open/Closed
Status

Common

/2 Cycle
Maximum
28 Vac
Pulse Source
1

28 Vac
Conductor
Plug (As Viewed
From End)

Solenoid
Auxiliary
Switch

Common

Circuit
Breaker
Open/Closed
Status

Solenoid
Auxiliary
Switch

Typical Single-Pole Circuit Breaker Schematic Diagram and
Conductor Plug Wiring Connections

Remote Control Operation
The remote-control capability of
the breaker is “armed” when the
breaker handle is manually switched
to the “ON” position. Once armed,
the breaker can be pulsed “ON” and
“OFF” by a controller device which
provides an ac pulse of specified
magnitude and duration to the solenoid operated mechanism. Control
connections to the breaker are provided through a male conductor
plug (supplied by others) which

PG.74A.01.T.E

Circuit Breaker Schematic Diagram and Conductor Plug Wiring
Connections for 2-Pole

snaps into the female connector
provided with the breaker.
A normally open (a) auxiliary contact provides for breaker “ON”/“OFF”
status indication to the remote
controller and/or indicating lamp.
The remote-control capability of the
breaker is “disarmed” when the
breaker handle is in the “OFF” or
“TRIPPED” position. In the event
the breaker automatically trips, the
breaker must be reset manually.

Breaker Solenoid and
Operating Data
■

Ambient Temperature:
0-40° C

■

Nominal Pulse Magnitude:
28 volts ac RMS

■

Tolerance: +10% to -15% of
Nominal Voltage

■

Pulse Duration: 1/2 cycle (8-10 ms)

■

Minimum Recommended Pulse
Current at Nominal Voltage:
1-Pole: 4.9 Amperes Peak,
3.5 Amperes RMS
2-Pole: 7.84 Amperes Peak,
5.6 Amperes RMS

■

Breaker Operating Time: 20-40 ms

■

Maximum Breaker Cycling:
6 Operations per Minute

■

Humidity: 0-95% non-Condensing

Time/Current Curves, Dimension Sheets, Application Data

16

Cutler-Hammer

Miniature Circuit Breakers
QUICKLAG Industrial Circuit Breakers

March 1999

QUICKLAG International Rated Industrial Circuit Breakers Plug-on, Bolt-on and Cable-in/Cable-out

Description

Breaker Catalog Numbers

QUICKLAG International
Circuit Breakers
Plug-on Type HQP: 10-100 Amperes
Bolt-on Type BA: 10-100 Amperes
Cable-in/Cable-out Type QC:
10-100 Amperes
Built and Test Certified to BS3871,
Pt. 1 50/60 Hz, 40°C
Interrupting Ratings
Suffix E

Suffix HE

NEMA
120/240 Vac

10,000 AIC

10,000 AIC

BS3871
220/380,
240/415 Vac

3,000 AIC

6,000 AIC

QUICKLAG International Ground
Fault Circuit Breakers
Plug-on Type GFXB: 10-40 Amperes
Bolt-on Type GFXBB: 10-40 Amperes
Cable-in/Cable-out Type GFXBC:
10-40 Amperes
Built and Test Certified to
BS3871, Pt. 1
BS3871, Section 31-C
BS4293
50/60 Hz, 40°C
30 mA Sensitivity
Interrupting Rating
BS3871
220/380, 240/415 Vac

3,000 AIC

Shipping Data
Miniature
Circuit
Breaker

No.
Std.
Approx. Approx.
of
Carton Carton Standard
Poles Qty.
Weight Carton
Dimensions
Lbs.
Inches (mm)
(Kgs)

QUICKLAG
Types B,
P, C – All

1

24

9.000 12.500 (317.50)
(4.09) x 7.500 (190.50)
x 5.000 (127.00)

QUICKLAG
Types B,
P, C – All

2

12

9.000 12.500 (317.50)
(4.09) x 7.500 (190.50)
x 5.000 (127.00)

QUICKLAG
Types B,
P, C – All

3

8

9.000 12.500 (317.50)
(4.09) x 7.500 (190.50)
x 5.000 (127.00)

QUICKLAG Ground Fault
Type P –
All

1

20

11.000 12.500 (317.50)
(4.99) x 6.500 (165.10)
x 5.000 (127.00)

Types B
and
C – All

1

20

11.000 12.500 (317.50)
(4.99) x 7.000 (177.80)
x 5.500 (139.70)

Types P
and
B – All

2

5

5.000 12.500 (317.50)
(2.27) 6.000 (152.40)
4.500 (114.30)

Continuous
Ampere
Rating at
40°C

Catalog Number
1-Pole

2-Pole

3-Pole

Gound Fault
1-Pole 30 mA
Sensitivity

240/415 Vac

240/415 Vac

240/415 Vac

240/415 Vac

3,000 Amperes I.C. (M3) Plug-on Thermal-Magnetic Circuit Breakers
HQP2010E
HQP1010E
10
HQP2015E
HQP1015E
15
–
–
16
HQP2020E
HQP1020E
20
HQP2025E
HQP1025E
25
HQP2030E
HQP1030E
30
–
–
32
HQP2040E
HQP1040E
40
HQP2050E
HQP1050E
50
HQP2060E
HQP1060E
60
HQP2070E
HQP1070E
70
HQP2090E
–
90
HQP2100E
–
100

HQP3010E
HQP3015E
–
HQP3020E
HQP3025E
HQP3030E
–
HQP3040E
HQP3050E
HQP3060E
HQP3070E
HQP3090E
HQP3100E

6,000 Ampere I.C. (M6) Plug-on Thermal-Magnetic Circuit Breakers
HQP1015HE
HQP2015HE
15
HQP1020HE
HQP2020HE
20
HQP1025HE
HQP2025HE
25
HQP1030HE
HQP2030HE
30
HQP1040HE
HQP2040HE
40
HQP1050HE
HQP2050HE
50
HQP2060HE
HQP1060HE
60
HQP2070HE
HQP1070HE
70
HQP2090HE
–
90
HQP2100HE
–
100

HQP3015HE
HQP3020HE
HQP3025HE
HQP3030HE
HQP3040HE
HQP3050HE
HQP3060HE
HQP3070HE
HQP3090HE
HQP3100HE

–
–
–
–
–
–
–
–
–
–

3,000 Ampere I.C. (M3) Bolt-on Thermal-Magnetic Circuit Breakers
BAB2010E
BAB1010E
10
BAB2015E
BAB1015E
15
–
–
16
BAB2020E
BAB1020E
20
BAB2025E
BAB1025E
25
BAB2030E
BAB1030E
30
–
–
32
BAB2040E
BAB1040E
40
BAB2050E
BAB1050E
50
BAB2060E
BAB1060E
60
BAB2070E
BAB1070E
70
BAB2090E
–
90
BAB2100E
–
100

BAB3010E
BAB3015E
–
BAB3020E
BAB3025E
BAB3030E
–
BAB3040E
BAB3050E
BAB3060E
BAB3070E
BAB3090E
BAB3100E

GFXBB110B2
GFXBB115B2
GFXBB116B2
GFXBB120B2
GFXBB125B2
GFXBB130B2
GFXBB132B2
GFXBB140B2
–
–
–
–
–

6,000 Ampere I.C. (M6) Bolt-on Thermal-Magnetic Circuit Breakers
BAB1015HE
BAB2015HE
15
BAB1020HE
BAB2020HE
20
BAB1025HE
BAB2025HE
25
BAB1030HE
BAB2030HE
30
BAB1040HE
BAB2040HE
40
BAB1050HE
BAB2050HE
50
BAB1060HE
BAB2060HE
60
BAB1070HE
BAB2070HE
70
BAB2090HE
–
90
BAB2100HE
–
100

BAB3015HE
BAB3020HE
BAB3025HE
BAB3030HE
BAB3040HE
BAB3050HE
BAB3060HE
BAB3070HE
BAB3090HE
BAB3100HE

GFXB110B2
GFXB115B2
GFXB116B2
GFXB120B2
GFXB125B2
GFXB130B2
GFXB132B2
GFXB140B2
–
–
–
–
–

–
–
–
–
–
–
–
–
–
–

3,000 Ampere I.C. (M3) Cable-in/Cable-out Thermal-Magnetic Circuit Breakers
QC3010E
QC2010E
QC1010E
10
QC3015E
QC2015E
QC1015E
15
–
–
–
16
QC3020E
QC2020E
QC1020E
20
QC3025E
QC2025E
QC1025E
25
QC3030E
QC2030E
QC1030E
30
–
–
–
32
QC3040E
QC2040E
QC1040E
40
QC3050E
QC2050E
QC1050E
50
QC3060E
QC2060E
QC1060E
60
QC3070E
QC2070E
QC1070E
70
QC3090E
QC2090E
–
90
QC3100E
QC2100E
–
100

GFXBC110B2
GFXBC115B2
GFXBC116B2
GFXBC120B2
GFXBC125B2
GFXBC130B2
GFXBC132B2
GFXBC140B2
–
–
–
–
–

6,000 Ampere I.C. (M6) Cable-in/Cable-out Thermal-Magnetic Circuit Breakers
QC2015HE
QC3015HE
QC1015HE
15
QC1020HE
QC2020HE
QC3020HE
20
QC1025HE
QC2025HE
QC3025HE
25
QC1030HE
QC2030HE
QC3030HE
30
QC1040HE
QC2040HE
QC3040HE
40
QC1050HE
QC2050HE
QC3050HE
50
QC3060HE
QC1060HE
QC2060HE
60
QC3070HE
QC1070HE
QC2070HE
70
QC3090HE
–
QC2090HE
90
QC3100HE
–
QC2100HE
100

–
–
–
–
–
–
–
–
–
–

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

Cutler-Hammer
March 1999

Miniature Circuit Breakers
QUICKLAG Industrial Circuit Breakers

17

QUICKLAG Industrial Circuit Breakers Special Application Breakers

Description
QUICKLAG Switching Neutral
Circuit Breakers
Plug-on Type HQP: 10-30 Amperes,
1 and 2 Poles, 10,000 AIC
Bolt-on Type BA: 10-30 Amperes,
1 and 2 Poles, 10,000 AIC
Cable-in Type QC: 10-30 Amperes,
1 and 2 Poles, 10,000 AIC
Switching Neutral QUICKLAG Breakers available in one- and two-pole
configurations, plus neutral pole for
applications in accordance with NEC
514-5, 240-22, and 380-2. A one-pole
device takes two pole spaces, and a
two-pole device takes three pole
spaces.

Breaker Catalog Numbers
Continuous
Ampere
Rating 40°C

Catalog Number
1-Pole➀

2-Pole➀

120/240 Vac

120/240 Vac

3-Pole➀
240 Vac

240 Vac

QUICKLAG Type: HQP Switching Neutral Thermal-Magnetic Breakers
10
15
20
25
30

HQP2010B
HQP2015B
HQP2020B
HQP2025B
HQP2030B

HQP3010B
HQP3015B
HQP3020B
HQP3025B
HQP3030B

–
–
–
–
–

–
–
–
–
–

–
–
–
–
–

–
–
–
–
–

–
–
–
–
–

–
–
–
–
–

QUICKLAG Type: BA Switching Neutral Thermal-Magnetic Breakers
10
15
20
25
30

BAB2010C
BAB2015C
BAB2020C
BAB2025C
BAB2030C

BAB3010C
BAB3015C
BAB3020C
BAB3025C
BAB3030C

QUICKLAG Type: QC Switching Neutral Thermal-Magnetic Breakers
10
15
20
25
30

QC2010B
QC2015B
QC2020B
QC2025B
QC2030B

QC3010B
QC3015B
QC3020B
QC3025B
QC3030B

QUICKLAG Type: HQP HID (High Intensity Discharge) Thermal-Magnetic Breakers
15
20
25
30
35
40
50
60

HQP2015D
HQP2020D
HQP2025D
HQP2030D
HQP2035D
HQP2040D
HQP2050D
HQP2060D

HQP1015D
HQP1020D
HQP1025D
HQP1030D
HQP1035D
HQP1040D
HQP1050D
HQP1060D

–
–
–
–
–
–
–
–

–
–
–
–
–
–
–
–

QUICKLAG Type: BA HID (High Intensity Discharge) Thermal-Magnetic Breakers

QUICKLAG Type P
Switching Neutral

15
20
25
30
35
40
50
60

BAB2015D
BAB2020D
BAB2025D
BAB2030D
BAB2035D
BAB2040D
BAB2050D
BAB2060D

BAB1015D
BAB1020D
BAB1025D
BAB1030D
BAB1035D
BAB1040D
BAB1050D
BAB1060D

–
–
–
–
–
–
–
–

–
–
–
–
–
–
–
–

QUICKLAG Type: QC HID (High Intensity Discharge) Thermal-Magnetic Breakers

QUICKLAG HID (High Intensity
Discharge) Breakers
Plug-on Type HQP: 15-60 Amperes,
1 and 2 Poles, 10,000 AIC
Bolt-on Type BA: 15-60 Amperes,
1 and 2 Poles, 10,000 AIC
Cable-in Type QC: 15-60 Amperes,
1 and 2 Poles, 10,000 AIC
Breakers designed specifically for
use with high intensity discharge
(HID) lighting applications. (UL listed
as standard lighting breakers.)
Molded Case Switches
Non-Automatic QUICKLAG Molded
Case Switch
Plug-on Type HQP: 50, 60,100
Amperes, 1, 2 and 3 Poles
Bolt-on Type BA: 50, 60,100
Amperes, 1, 2 and 3 Poles
Cable-in Type QC: 50, 60,100
Amperes, 1, 2 and 3 Poles

➀ All products UL and CSA listed.

PG.74A.01.T.E

15
20
25
30
35
40
50
60

QC1015D
QC1020D
QC1025D
QC1030D
QC1035D
QC1040D
QC1050D
QC1060D

QC2015D
QC2020D
QC2025D
QC2030D
QC2035D
QC2040D
QC2050D
QC2060D

–
–
–
–
–
–
–
–

–
–
–
–
–
–
–
–

QUICKLAG Type: HQP Non-Auto Molded Case Switches
50
60
100

HQP1050N
HQP1060N
HQP1100N

–
–
–

HQP2050N
HQP2060N
HQP2100N

HQP3050N
HQP3060N
HQP3100N

BAB2050N
BAB2060N
BAB2100N

BAB3050N
BAB3060N
BAB3100N

QC2050N
QC2060N
QC2100N

QC3050N
QC3060N
QC3100N

QUICKLAG Type: BA Non-Auto Molded Case Switches
50
60
100

BAB1050N
BAB1060N
BAB1100N

–
–
–

QUICKLAG Type: QC Non-Auto Molded Case Switches
50
60
100

QC1050N
QC1060N
QC1100N

–
–
–

Shipping Data
Miniature Circuit Breaker

No.
Standard
of
Carton
Poles Quantity

Approximate Approximate Standard Carton
Carton Weight Dimensions Inches (mm)
Lbs. (Kgs)

QUICKLAG Types B, P, C – All
QUICKLAG Types B, P, C – All
QUICKLAG Types B, P, C – All

1
2
3

24
12
8

9.000 (4.09)
9.000 (4.09)
9.000 (4.09)

12.500 (317.50) x 7.500 (190.50) x 5.000 (127.00)
12.500 (317.50) x 7.500 (190.50) x 5.000 (127.00)
12.500 (317.50) x 7.500 (190.50) x 5.000 (127.00)

QUICKLAG Ground Fault
Type P – All
Types B and C – All
Types P and B – All

1
1
2

20
20
5

11.000 (4.99)
11.000 (4.99)
5.000 (2.27)

12.500 (317.50) x 6.500 (165.10) x 5.000 (127.00)
12.500 (317.50) x 7.000 (177.80) x 5.500 (139.70)
12.500 (317.50) x 6.000 (152.40) x 4.500 (114.30)

18

Cutler-Hammer

Miniature Circuit Breakers
QUICKLAG Industrial Circuit Breakers

March 1999

QUICKLAG Industrial Circuit Breakers Accessories
Accessory Type➀

Catalog Number

Description

Order in Multiples of

Handle Locks:
Non-padlockable

QL1NPL
QL23NPL

QUICKLAG Type P, B, C – 1 Pole
QUICKLAG Type P, B, C – 2, 3 Poles

10
10

Handle Locks:
Padlockable

QL1PL
QLPB123PL
QC123PL
QLGF12PL

QUICKLAG Type P, B, C – 1 Pole
QUICKLAG Type P, B – 1, 2, 3 Poles
QUICKLAG Type C – 1, 2, 3 Poles
Ground Fault Padlock Device Type P, B – 1, 2 Poles

10
10
10
10

Handle Tie

QL1HT

QUICKLAG Handle Tie - 1 Pole

100

Mounting Hardware

QCFCLIP
QC1FP
QC2FP
QC3FP
QC1FPLOFF
QC2FPLOFF
QC3FPLOFF
QCBCLIP
QC6BP
QC4CONB
QCDINADAPT

QUICKLAG Type C Face Mounting Clip
QUICKLAG Type C Face Mounting Plate – 1 Pole
QUICKLAG Type C Face Mounting Plate – 2 Poles
QUICKLAG Type C Face Mounting Plate – 3 Poles
QUICKLAG Type C Face Mounting Plate and Lock-off (Off Only) – 1 Pole
QUICKLAG Type C Face Mounting Plate and Lock-off (Off Only) – 2 Pole
QUICKLAG Type C Face Mounting Plate and Lock-off (Off Only) – 3 Pole
QUICKLAG Type C Base Mounting Clamp
QUICKLAG Base Mounting Plate – 6 Poles Total
QUICKLAG Type C Single Point Connector
QUICKLAG Type C DIN Rail Adapter

24
10
10
10
10
10
10
100
10
10
6

Dummy Breakers

HQP1000
BAB1000
QC1000
QC30SAMPLE

QUICKLAG Type P
QUICKLAG Type B
QUICKLAG Type C
QUICKLAG Type C Clear Choice Breaker

QL1NPL

QL1HT

QCBCLIP

QL23NPL

QCFCLIP

QC6BP

QL1PL

1
1
1
4

QLPB123PL

QC1FP

QC2FP

QC4CONB

QC123PL

QC3FP

QCDINADAPT

➀ See pages 7 and 8 for QCR and QCF accessories.

PG.74A.01.T.E

Cutler-Hammer

Miniature Circuit Breakers
QUICKLAG Industrial Circuit Breakers

March 1999

19

QUICKLAG Industrial Circuit Breakers Modifications/Terminals
Factory Modifications➀
Type of Modification

Breaker Types

Shunt Trip (Requires 1 extra pole space on right side)
120, 208, 240 Vac
12, 24, 48 Vac/dc
Draws 2.6A at 120V
Draws 11A at 24Vdc

Catalog Suffix

QUICKLAG Types P, B and C
QUICKLAG Types P, B and C

S
S1

Special Calibration (50°C)

QUICKLAG Types P, B and C

V

Shock Testing

QUICKLAG Types P, B and C

L

Freeze Testing

QUICKLAG Types P, B and C

Y

Moisture-Fungus Treatment

QUICKLAG Types P, B, C and Ground Fault

F

Factory Installed Breaker Terminals
Breaker Type

Continuous
Ampere
Rating

Standard Line Terminal
Term
Type

Wire
Type

Standard Load Terminal
Wire
Range

Term
Type

Optional Terminals
(20% List Price Adder)
Wire
Type

Wire
Range

Line

Load

QUICKLAG Type P
HQP, QPHW,
QHPX, QHPW

10 to 30
35 to 50
55 to 125

Plug-on female clips which mate
with the bus stabs

A
B
C

Cu/Al
Cu/Al
Cu/Al

#14-#4
#14-#4
#8-1/0

N/A

C
C
–

QUICKLAG Ground Fault
QPGF, QPHGF,
QPGFEP, QPHGFEP

10 to 30

Plug-on female clips which mate
with the bus stabs

A – 1-pole
D – 2-pole
D

Cu/Al
Cu/Al
Cu

#14-#4
#14-#8
#14-#8

N/A

C
C
–

QUICKLAG Type B
BAB, QBHW,
HBAX, HBAW

10 to 30
35 to 50
55 to 125

Extended tangs which bolt
directly to the bus

A – 1- and 2- pole
B – 3-pole
C

Cu/Al
Cu/Al
Cu/Al

#14-#4
#14-#4
#8-1/0

N/A

C
C
–

QUICKLAG Ground Fault
QBGF, QBHGF,
QBGFEP, QBHGFEP

10 to 30

Extended tangs which bolt
directly to the bus

A – 1-pole
D – 2-pole
D

Cu/Al
Cu/Al
Cu

#14-#4
#14-#8
#14-#8

N/A

N/A

QUICKLAG Type C
QC, QCHW,
QHCX, QHCW

10 to 20
25 to 60
70 to 100

E
F
G

Cu/Al
Cu/Al
Cu/Al

#14-#10

E
B
C

Cu/Al
Cu/Al
Cu/Al

#14-#10
#14-#4
#8-1/0

F, G
E, G
E

F, G, H
E, F, G, H
E, G, H

QUICKLAG
QCR, QCF

10-55
60

A
A

Cu/Al
Cu

-#14
-#4

A
A

Cu/Al
Cu

#14
-#4

N/A

N/A

QUICKLAG Ground Fault
QCGF, QCHGF,
QCGFEP, QCHGFEP

10 to 20
25 to 50

E
F

Cu/Al
Cu/Al

#14-#10

A
A

Cu/Al
Cu/Al

#14-#4
#14-#4

F, G
E, G

N/A

40

40

A

B

C

D

E

F

G

H

Catalog Suffix “P”

Spare Terminal Hardware Screws (Lugs not Included)
Catalog Number

QLLDTSA
QLLDTSB
QLLDTSC
QLBHTSE
QLLNTSFG

Order in Multiples of

10
10
10
10
10

Terminal Type

Description

A
B
C
E
F and G

➀ Contact Cutler-Hammer for factory modifications available for QCR and QCF breakers.

PG.74A.01.T.E

QUICKLAG Terminal Screw
QUICKLAG Terminal Screw
QUICKLAG Terminal Screw
QUICKLAG Binding Head Terminal Screw and Clamp
QUICKLAG Terminal Screw

Time/Current Curves, Dimension Sheets, Application Data

20

Cutler-Hammer

Miniature Circuit Breakers
SPCL Supplementary Protectors

March 1999

Supplementary Protectors Current Limiting Type Cable-in/Cable-out DIN Rail
SPCL Specifications
Standards
and Approvals

Number
of Poles

UL 1077
File No. E162396

Description
UL 1077 Supplementary Protectors
Type SPCL Supplementary Protectors are IEC circuit breakers that are
recognized by UL under UL 1077.
They are intended for use as overcurrent protection within an appliance or electrical equipment where
branch circuit protection (for example a UL listed Molded Case Circuit
Breaker) has already been provided
or is not required.
Equipment and Control
Circuit Protection
These protectors are ideal for replacing fuses in control circuits. Applications include protecting motor
control circuits, small control circuit
transformers, relays, contactor coils,
power supplies, PLC I/O points, appliances, and electronic equipment.

CSA 22.2
File No. LR105580-1

EN60898
V
DE

Overcurrent Curves

Thermal-Magnetic Overcurrent
Protection: Types B and C overcurrent curves provide maximum
reliability and accuracy. Type B
protection is normally used for low
inrush applications. Type C protection is used for general purpose
industrial applications that require
higher inrush tolerance.
Center Trip Position: The breaker
handle has a unique center trip
“Reset” position that indicates an
overcurrent trip. “Off” (O) and “On”
(I) handle positions are visually indicated by red and green flags.

Vac
50/60 Hz

Vdc

1

0.5-63

120

12-65

2

0.5-63

240

12-130➀

3-4

0.5-63

240

Ampere Interrupting
Capacity

10 kA
10 kA
10 kA

1

0.5-63

277

6 kA

2-4

0.5-63

480

5 kA

1-4

0.5-63

240/415

10 kA

Overcurrent Curve Type B (3-5X) and Type C (5-10X) per VDE 0641, Part 11.

Degree of Protection IP20.
Connecting
Terminals

Suitable for Single-Core, Standard, and Flexible Conductors from #14 to #6 AWG (Cu).
Recommended Torque is 27 Inch-Pounds.

SPCL Supplementary Protector Catalog Numbers
Continuous
Ampere Rating

Catalog Number
1-Pole

2-Pole

3-Pole

4-Pole

C Curve

The Type SPCL Supplementary
Protectors are provided in light gray
cases with charcoal gray handles.

Current-Limiting Design: Fast short
circuit interruption reduces letthrough energy, reducing damage
to the circuit.

Continuous Current
(Amperes)

VDE0660

Product Features

DIN-Rail Mounting: A quick snap-on
clip design allows easy installation
on 35mm DIN Rail.

Electrical Ratings

0.5
1
2
3
4
5
6
7
8
10
13
16
20
25
32
40
50
63

SPCL1C00
SPCL1C01
SPCL1C02
SPCL1C03
SPCL1C04
SPCL1C05
SPCL1C06
SPCL1C07
SPCL1C08
SPCL1C10
SPCL1C13
SPCL1C16
SPCL1C20
SPCL1C25
SPCL1C32
SPCL1C40
SPCL1C50
SPCL1C63

SPCL2C00
SPCL2C01
SPCL2C02
SPCL2C03
SPCL2C04
SPCL2C05
SPCL2C06
SPCL2C07
SPCL2C08
SPCL2C10
–
SPCL2C16
SPCL2C20
SPCL2C25
SPCL2C32
SPCL2C40
SPCL2C50
SPCL2C63

SPCL3C00
SPCL3C01
SPCL3C02
–
SPCL3C04
–
SPCL3C06
–
–
SPCL3C10
–
SPCL3C16
SPCL3C20
SPCL3C25
SPCL3C32
SPCL3C40
SPCL3C50
SPCL3C63

SPCL4C00
SPCL4C01
SPCL4C02
–
SPCL4C04
–
SPCL4C06
–
–
SPCL4C10
–
SPCL4C16
SPCL4C20
SPCL4C25
SPCL4C32
SPCL4C40
SPCL4C50
SPCL4C63

6
10
13
16
20
25
32
40
50
63

SPCL1B06
SPCL1B10
SPCL1B13
SPCL1B16
SPCL1B20
SPCL1B25
SPCL1B32
SPCL1B40
SPCL1B50
SPCL1B63

SPCL2B06
SPCL2B10
–
SPCL2B16
SPCL2B20
SPCL2B25
SPCL2B32
SPCL2B40
SPCL2B50
SPCL2B63

SPCL3B06
SPCL3B10
–
SPCL3B16
SPCL3B20
SPCL3B25
SPCL3B32
SPCL3B40
SPCL3B50
SPCL3B63

SPCL4B06
SPCL4B10
–
SPCL4B16
SPCL4B20
SPCL4B25
SPCL4B32
SPCL4B40
SPCL4B50
SPCL4B63

B Curve

Shipping Data
Packed in
Cartons of:

1-Pole Units
2-Pole Units
3-Pole Units
4-Pole Units

12
6
4
3

Carton Dimensions
Inches (mm)

Approximate
Weight Lbs.
(Kgs)

9.000 (228.60) x 4.000 (101.60) x 4.000 (101.60)
9.000 (228.60) x 4.000 (101.60) x 4.000 (101.60)
9.000 (228.60) x 4.000 (101.60) x 4.000 (101.60)
9.000 (228.60) x 4.000 (101.60) x 4.000 (101.60)

➀ 130 Vdc rating based on 2 poles connected in
series.
 Normally stocked.
 Special order, contact Cutler-Hammer.
Minimum quantities apply.

10.000 (4.54)
10.000 (4.54)
10.000 (4.54)
10.000 (4.54)

CE Mark
SPCL protectors carry the CE mark in
accordance with Low Voltage Directive
(LVD) (73/23/EEC)

PG.74A.01.T.E

Cutler-Hammer
March 1999

Miniature Circuit Breakers
SPCL Supplementary Protectors

21

Supplementary Protectors Current Limiting Type Cable-in/Cable-out DIN Rail

SPCL Accessories

Figure 1
Wiring Diagram

Auxiliary/Signal Switch Kit
Catalog Number SPCLUAUX is a
field mountable switch kit that
attaches to the left side of a SPCL
Protector. It is field selectable to
auxiliary or signal (bell alarm) configuration. The switch is UL and CSA
approved for general purpose
ratings of 6 ampere at 240 Vac or
1 ampere at 125 Vdc. Contacts are
provided as indicated on the wiring
diagram. Screw-type terminals are
provided to accommodate up to #16
AWG wire. Recommended torque is
approximately 13 inch-pounds.

12
21
14

Signaling
Switch

22
11

Auxiliary
Switch

Contact Charts
Contacts

Auxiliary Switch Mode
Protector
Open

Protector Closed

11 to 12

X

0

11 to 14

0

X

21 to 22

X

0

Contacts

Figure 2

Signal Switch Mode
Protector
Open

Protector
Closed

Protector
Tripped

11 to 12

0

0

11 to 14

X

X

X
0

21 to 22

0

0

X

Technical Data

PG.74A.01.T.E

Rated Voltage:

230 Vac/110 Vdc

Rated Current:

6A Ac/1A Dc

Conductor Cross
Section:

To 1.5 mm2
(No 16 AWG)

Tightening Torque:

1 Nm
(13 inch-pounds)

Product:

Catalog Number

Universal Auxiliary
Switch:

SPCLUAUX

Figure 3

22

Cutler-Hammer

Miniature Circuit Breakers
SPCL Supplementary Protectors

March 1999

Supplementary Protectors Current Limiting Type Cable-in/Cable-out DIN Rail

SPCL Accessories
Lock-off Devices
Lock-off Devices
Catalog Number

Description

SPCLPLDEV

Padlockable device, mounts on protector and includes provisions to accept
catalog number SPCLOCKEY Padlock

SPCLOCKEY

Padlock with 3 keys

Bus Bar Systems
Bus Bar Systems
Catalog Number

Description

SPCLIPB10MM

Single-phase 240 Vac VDE approved Bus Bar, 1 meter in length, 10mm2 density

SPCL1PB16MM

Single-phase 240 Vac VDE approved Bus Bar, 1 meter in length, 16mm2 density

Maximum Bus Bar Current➀
Conductor Density

End Connect

Center Connect

10 sq. mm

50 Amperes

100 Amperes

16 sq. mm

65 Amperes

130 Amperes

Finger Proofing Shield
Finger Proofing Shield
Catalog Number

SPCL2000

Description

Clip-on finger proofing shield to enhance finger protection on SPCL protectors.
Plastic finger proofing shield clips into upper or lower terminal poles as required.

➀ Per VDE 0606.

PG.74A.01.T.E

Cutler-Hammer

Miniature Circuit Breakers
SPHM Supplementary Protectors

March 1999

23

Supplementary Protectors Hydraulic Magnetic Type Cable-in/Cable-out DIN Rail

Description
UL 1077 Supplementary Protectors
Type SPHM Supplementary Protectors are IEC circuit breakers that are
recognized by UL under UL 1077.
They are intended for use as overcurrent protection within an appliance or electrical equipment where
branch circuit protection (for example a UL listed Molded Case Circuit
Breaker) has already been provided
or is not required.

Catalog Numbering System
SPHM

3

H

0030

M

Auxiliary
Switch

Type
Supplementary
Protector
Hydraulic
Magnetic

Poles
Code
1
2
3
4

Code Current
A➀
Normally
Open➁
B➀
Normally
Current
Closed➁
Rating

Poles
1-Pole
2-Pole
3-Pole
4-Pole

Inrush
Delay

Equipment and Control Circuit
Applications

Code Delay

Voltage

Code Delay

Curve

H

8X

50/60 Hz

R

18X

50/60 Hz

Y➃

25X

50/60 Hz

Product Features

J

8X

Dc

The Type SPHM Supplementary Protectors are provided in light gray cases
with charcoal gray handles. Handles
are marked with “O” for “Off” and “I”
for “On”.

S

18X

Dc

Z➃

25X

Dc

2
3
10
20
30
251
252
253
2
3
10
20
30
251
252
253

DIN Rail Mounting: Easy installation
on 35mm DIN Rail. A spring loaded
clip is provided for quick release
from the DIN Rail mounting.

S

Switch Dc, 50/60 Hz

M
S
L
M
S
L
M
S
M
S
L
M
S
L
M
S
W

These protectors are ideal for protecting motor control circuits, CPTs,
relays, contactor coils, power supplies,
PLC I/O points, lighting circuits, appliances, electronic equipment, and
replacing fuses.

Precise Overcurrent Calibration: The
protector can be precisely calibrated
to a wide variety of current ranges
from 0.1 to 50 amperes continuous.
For special ratings not shown, contact Cutler-Hammer.
Flexible Time-Characteristic Curves:
Long, Medium, and Short Delay
Curves are available. Long Delay are
for special extended inrush, Medium
➀ One A or B contact maximum per pole.
Contacts will be arranged left to right (e.g.,)
BAB suffix on 3-pole breaker.
➁ Contact position when breaker in open condition. Contacts rated 10 amperes at 250 Vac.
➂ UL recognized to 250 Vac, 5 kA above 30
amperes.
➃ Maximum of 40 amperes available at 25X
inrush.

PG.74A.01.T.E

Current➂
0.10 Ampere
0.25 Ampere
0.50 Ampere
0.75 Ampere
1 Ampere
2.5 Ampere
5 Ampere
7.5 Ampere
10 Ampere
15 Ampere
20 Ampere
25 Ampere
30 Ampere
35 Ampere
40 Ampere
50 Ampere

–

General Specifications and Electrical Ratings
Standards and
Approvals

Heat-Induced Nuisance Tripping
Eliminated: The protector is designed
to “hold in” at 100% of continuous
rated current regardless of ambient
temperatures from -40 to +85°C.
Immediate Reset After Trip: The protector can be reset (closed) immediately after an overcurrent trip
without a “cooling off” period.

Medium
Short
Long
Medium
Short
Long
Medium
Short
Medium
Short
Long
Medium
Short
Long
Medium
Short
Switch

Code
00R1
0R25
0R50
0R75
0001
02R5
0005
07R5
0010
0015
0020
0025
0030
0035➂
0040➂
0050➂

UL 1077

Continuous
Current Rating

Vac 50/60 Hz

Vdc

Interruption Cap Capacity
RMS Symmetrical

0.1 to 30 Amperes

277/480

3 kA

0.1 to 50 Amperes

250

5 kA

CSA 22.2

0.1 to 50 Amperes

VDE 0660

0.1 to 50 Amperes

IEC-380

0.1 to 50 Amperes

for general purpose, and Short Delay
for sensitive electronic applications.
/2 Cycle High-Inrush Tolerance: The
protector can be provided with tolerance to various levels of 1/2 cycle
current spikes. General purpose
tolerance is 8X the continuous
current rating. Tolerance to 18X
and 25X are also available.

1

Environmental, Vibration, and
Shock Resistance: Mil-Spec qualification for fungus resistance, humidity, salt-spray resistance, and shock
vibration resistance.
Integral Auxiliary Switch (Optional):
One auxiliary switch contact (a or b)
can be factory installed per protector
pole. A separate pole for the contact
is not required.

80
230/400

5 kA
1.5 kA

80

2 kA

Standards: UL Recognized under
UL 1077, CSA Certified to CSA 22.2.
Meets the requirements of IEC-380,
IEC-435, IEC-601, VDE 0660, VDE
601, VDE 0730, VDE 0750, VDE 0804,
VDE 0806
Inrush Tolerance: 8X (Standard),
18X, or 25X
Overcurrent Curves: Long Delay,
Medium Delay, or Short Delay
Operating Temperature: -40 to +85°C
Wire Range: Breaker Terminals:
14-6 AWG Copper, 35-inch-lbs
torque Auxiliary Switch Terminals:
16 AWG Copper, 3.5-inch-lbs torque
Auxiliary Switch: 10 Amperes at
250 Vac
Degree of Protection: IP-20

Time/Current Curves, Dimension Sheets, Application Data

24

Cutler-Hammer

Miniature Circuit Breakers
SPHM Supplementary Protectors

March 1999

Supplementary Protectors Hydraulic Magnetic Type Cable-in/Cable-out DIN Rail

1-Pole

2-Pole

3-Pole

4-Pole

SPHM Catalog Numbers
Continuous
Current
Rating
(Amperes)

0.1
0.25
0.50
0.75
1
2.5
5.0
7.5
10
15
20
25
30
Continuous
Current Rating
(Amperes)

35
40
50
Continuous
Current Rating
(Amperes)

0.1
0.25
0.50
0.75
1
2.5
5
7.5
10
15
20
25
30
Continuous
Current Rating
(Amperes)

35
40
50

Catalog Number
8X (Standard Inrush Tolerance) Medium Delay Curve 2
1-Pole 277 Vac

SPHM1HM00R1
SPHM1HM0R25
SPHM1HM0R50
SPHM1HM0R75
SPHM1HM0001
SPHM1HM02R5
SPHM1HM0005
SPHM1HM07R5
SPHM1HM0010
SPHM1HM0015
SPHM1HM0020
SPHM1HM0025
SPHM1HM0030

2-Pole 277/480 Vac

3-Pole 277/480 Vac

SPHM2HM00R1
SPHM2HM0R25
SPHM2HM0R50
SPHM2HM0R75
SPHM2HM0001
SPHM2HM02R5
SPHM2HM0005
SPHM2HM07R5
SPHM2HM0010
SPHM2HM0015
SPHM2HM0020
SPHM2HM0025
SPHM2HM0030

SPHM3HM00R1
SPHM3HM0R25
SPHM3HM0R50
SPHM3HM0R75
SPHM3HM0001
SPHM3HM02R5
SPHM3HM0005
SPHM3HM07R5
SPHM3HM0010
SPHM3HM0015
SPHM3HM0020
SPHM3HM0025
SPHM3HM0030

4-Pole 277/480 Vac

SPHM4HM00R1
SPHM4HM0R25
SPHM4HM0R50
SPHM4HM0R75
SPHM4HM0001
SPHM4HM02R5
SPHM4HM0005
SPHM4HM07R5
SPHM4HM0010
SPHM4HM0015
SPHM4HM0020
SPHM4HM0025
SPHM4HM0030

8X (Standard Inrush Tolerance) Medium Delay Curve 2
1-Pole 250 Vac

SPHM1HM0035
SPHM1HM0040
SPHM1HM0050

2-Pole 250 Vac

3-Pole 250 Vac

SPHM2HM0035
SPHM2HM0040
SPHM2HM0050

SPHM3HM0035
SPHM3HM0040
SPHM3HM0050

4-Pole 250 Vac

SPHM4HM0035
SPHM4HM0040
SPHM4HM0050

18X (High Inrush Tolerance) Medium Delay Curve 20
1-Pole 277 Vac

SPHM1RM00R1
SPHM1RM0R25
SPHM1RM0R50
SPHM1RM0R75
SPHM1RM0001
SPHM1RM02R5
SPHM1RM0005
SPHM1RM07R5
SPHM1RM0010
SPHM1RM0015
SPHM1RM0020
SPHM1RM0025
SPHM1RM0030

2-Pole 277/480 Vac

3-Pole 277/480 Vac

SPHM2RM00R1
SPHM2RM0R25
SPHM2RM0R50
SPHM2RM0R75
SPHM2RM0001
SPHM2RM02R5
SPHM2RM0005
SPHM2RM07R5
SPHM2RM0010
SPHM2RM0015
SPHM2RM0020
SPHM2RM0025
SPHM2RM0030

SPHM3RM00R1
SPHM3RM0R25
SPHM3RM0R50
SPHM3RM0R75
SPHM3RM0001
SPHM3RM02R5
SPHM3RM0005
SPHM3RM07R5
SPHM3RM0010
SPHM3RM0015
SPHM3RM0020
SPHM3RM0025
SPHM3RM0030

4-Pole 277/480 Vac

SPHM4RM00R1
SPHM4RM0R25
SPHM4RM0R50
SPHM4RM0R75
SPHM4RM0001
SPHM4RM02R5
SPHM4RM0005
SPHM4RM07R5
SPHM4RM0010
SPHM4RM0015
SPHM4RM0020
SPHM4RM0025
SPHM4RM0030

18X (High Inrush Tolerance) Medium Delay Curve 20
1-Pole 250 Vac

SPHM1RM0035
SPHM1RM0040
SPHM1RM0050

2-Pole 250 Vac

3-Pole 250 Vac

SPHM2RM0035
SPHM2RM0040
SPHM2RM0050

SPHM3RM0035
SPHM3RM0040
SPHM3RM0050

4-Pole 250 Vac

SPHM4RM0035
SPHM4RM0040
SPHM4RM0050

Shipping Data
Shipped in
Cartons of:

 Normally stocked.
 Special order, contact Cutler-Hammer.
Minimum quantities apply. Contact
Cutler-Hammer for price and availability
for 400 Hz, Dc, Auxiliary Switch, and other
catalog number combinations not shown.

1-Pole Units
2-Pole Units
3-Pole Units
4-Pole Units

12
6
4
3

Carton Dimensions Inches (mm)

10.500 (266.70) x 4.125 (104.78) x 4.500 (114.30)
10.500 (266.70) x 4.125 (104.78) x 4.500 (114.30)
10.500 (266.70) x 4.125 (104.78) x 4.500 (114.30)
10.500 (266.70) x 4.125 (104.78) x 4.500 (114.30)

Approx. Weight
Lbs. (Kgs)

15.000 (6.81)
15.000 (6.81)
15.000 (6.81)
15.000 (6.81)

PG.74A.01.T.E

Cutler-Hammer

Molded Case Circuit Breakers
15-100 Amperes

March 1999

25

Series C G-Frame
■

■

■

■

Interrupting Capacity Ratings

All two- and three-pole circuit
breakers are of the common trip
type. On all 3-phase Delta (240V)
Grounded B phase applications,
refer to Cutler-Hammer.

UL489 Interrupting Capacity Ratings
Circuit
Breaker
Type

Number
of Poles

Interrupting Capacity (Symmetrical Amperes) (kA)
Volts Ac (50/60 Hz)
120

Single-pole circuit breakers, 15
and 20 amperes. Switching duty
rated (SWD) for fluorescent lighting applications.

GD
Circuit
Breaker
Type

All G-frame circuit breakers are
suitable for reverse feed use.

3
Number
of Poles

240

–

277

65

480

–

125

22

250➀➁

–

10

Interrupting Capacity (Symmetrical Amperes) (kA)
Volts Ac (50/60 Hz)
120

HACR rated.

Page
Number

Volts Dc

Page
Number

Volts Dc

240

277

480Y/277

125

26

125/250

GB

1
2, 3

65
–

–
65

–
–

–
–

14➂
–

–
14

27
27

GHB

1
2, 3

65
–

–
65

14
–

–
14

14➂
–

–
14

27
27

GC

1
2, 3

65
–

–
65

–
–

–
–

14➂
–

–
14

28
28

GHC

1
2, 3

65
–

–
65

14
–

–
14

14➂
–

–
14

28
28

Catalog Numbering System

Terminal Types

This information is presented only as an aid to understanding catalog numbers. It is not to be used to build
catalog numbers for circuit breakers or trip units.

For line and load-side. Terminals are UL listed as suitable
for wire type and size given below.

Circuit Breaker/Frame Catalog Number
GD 3 100

15-20
25-100

Number
of Poles

Trip
Amperes

Suffix

GD
GB
GHB
GC
GHC

1: 1 Pole
2: 2 Pole
3: 3 Pole

15
20
24
30
35
40
45
50
60
70
80
90
100

K:
D:
C:
V:
J01:
R01:
F01:

Two poles of 3-pole circuit breaker.
Time constant is 8 milliseconds minimum.
15 through 70A breakers only.
Not UL listed sizes.

PG.74A.01.T.E

Terminal
Type
Material

Screw
Head
Type

Wire
Type

AWG
Wire
Range

Metric Wire➃
Range (mm2)

Standard

Circuit
Breaker
Type

➀
➁
➂
➃

Circuit
Breaker
Amperes

2.5-4
4-50

Optional
15-50

Molded Case Switch
Ring Type Terminals
Steel Collars
50°C
Fungus Proofed
Shock Tested
Freeze Tested

Clamp (Plated Steel)
Slotted Cu/Al #14-10
Pressure (Aluminum Body) Slotted Cu/Al #10-1/0
Pressure (Steel Body)

Slotted Cu

–

–

Time/Current Curves, Dimension Sheets, Application Data

26

Cutler-Hammer

Molded Case Circuit Breakers
15-100 Amperes

March 1999

Series C G-Frame

Type GD Thermal-Magnetic Circuit Breakers with Non-Interchangeable
Trip-Units
Maximum
Continuous
Ampere Rating
@ 40°C

480 Vac Maximum, 250 Vdc➀

Catalog Number
(Includes binding
head screws)

22 kAIC @ 480 Vac
Catalog Number (Includes Line and
Load Terminals)

3-Pole

Typical Series C G-Frame Circuit Breaker

GD3015D
GD3020D
GD3025D
GD3030D
GD3035D
GD3040D
GD3045D
GD3050D
GD3060D
GD3070D
GD3080D
GD3090D
GD3100D

GD3015
GD3020
GD3025
GD3030
GD3035
GD3040
GD3045
GD3050
GD3060
GD3070
GD3080
GD3090
GD3100

15
20
25
30
35
40
45
50
60
70
80
90
100

Instruction Leaflet/FRED Number 29C102

Molded Case Switches
Maximum
Continuous
Ampere Rating
@ 40°C

480 Vac Maximum, 250 Vdc
Catalog Number (Includes Line and Load Terminals)

3-Pole
60
100

GD3060K
GD3100K

Instruction Leaflet/FRED Number 29C102

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

Cutler-Hammer

Molded Case Circuit Breakers
15-100 Amperes

March 1999

27

Series C G-Frame

Types GB and GHB Bolt-On Panelboard Circuit Breakers
Type GB Thermal-Magnetic Circuit Breakers with Non-Interchangeable Trip Units
Continuous
Ampere Rating
@ 40°C

120 Vac Maximum,
125 Vdc Maximum➀

240 Vac Maximum,
125/250 Vdc Maximum

240 Vac Maximum,
125/250 Vdc Maximum➁

1-Pole

2-Pole

3-Pole

Catalog Number

Typical GB

These breakers meet the requirements of Federal Specification
W-C-375b as follows:
Types GB, GHB, 120 and 240 Volts:
1 Pole: Class 11a.
2, 3 Poles: Classes 10b, 11b, 12b,
14b, 15b

GB1015➂
GB1020➂
GB1025
GB1030
GB1035
GB1040
GB1045
GB1050
GB1060
GB1070
GB1080
GB1090
GB1100

15
20
25
30
35
40
45
50
60
70
80
90
100

GB2015➂
GB2020➂
GB2025
GB2030
GB2035
GB2040
GB2045
GB2050
GB2060
GB2070
GB2080
GB2090
GB2100

GB3015➂
GB3020➂
GB3025
GB3030
GB3035
GB3040
GB3045
GB3050
GB3060
GB3070
GB3080
GB3090
GB3100

Type GHB Thermal-Magnetic Circuit Breakers with Non-Interchangeable Trip Units➃
Continuous
Ampere Rating
@ 40°C

Type GHB, 277 and 480Y/277 Volts:
1 Pole: Classes 12c, 13a
2, 3 Poles: Class 13b

277/480 Vac Maximum,
125 Vdc Maximum➀

277/480 Vac Maximum,
125/250 Vdc Maximum

277/480 Vac Maximum,
125/250 Vdc Maximum➁

1-Pole

2-Pole

3-Pole

Catalog Number

GHB1015➂
GHB1020➂
GHB1025
GHB1030
GHB1035
GHB1040
GHB1045
GHB1050
GHB1060
GHB1070
GHB1080
GHB1090
GHB1100

15
20
25
30
35
40
45
50
60
70
80
90
100

GHB2015➂
GHB2020➂
GHB2025
GHB2030
GHB2035
GHB2040
GHB2045
GHB2050
GHB2060
GHB2070
GHB2080
GHB2090
GHB2100

GHB3015➂
GHB3020➂
GHB3025
GHB3030
GHB3035
GHB3040
GHB3045
GHB3050
GHB3060
GHB3070
GHB3080
GHB3090
GHB3100

Instruction Leaflet/FRED Number 15547

Type GHBGFEP Bolt-on Panelboard 30mA Industrial Ground Fault Circuit Protectors
15-60 Amperes, 277 Volt, 50/60 Hz
These circuit breakers meet the
requirements of UL489 and UL1053.
Operational voltage 240V to 305V.
Interrupting Capacity Ratings
Circuit
Breaker
Type

GHBGFEP

Number
of Poles

2

Interrupting Capacity
(Symmetrical Amperes)
277 Volts Ac (50/60 Hz)

14,000

Type GHBGFEP Bolt-on Panelboard 30mA
Industrial Ground Fault Circuit Protectors
with Non-Interchangeable Trip Units
Continuous
Ampere
Rating
@ 40°C

15
20
30
40
50
60

One Phase (Requires 2 Poles)
277V, 30mA
Catalog Number

GHBGFEP1015
GHBGFEP1020
GHBGFEP1030
GHBGFEP1040
GHBGFEP1050
GHBGFEP1060

Instruction Leaflet/FRED Number 29C193

Single Phase
(Requires 2 Poles)

PG.74A.01.T.E

➀
➁
➂
➃

15 through 70 ampere circuit breakers only.
Use (2) outside poles.
Uses .190-32 screw type clamp terminals.
480Y/277V, circuit breakers (Type GHB)
not suitable for 3-phase Delta (480V).

Time/Current Curves, Dimension Sheets, Application Data

28

Cutler-Hammer

Molded Case Circuit Breakers
15-100 Amperes

March 1999

Series C G-Frame

Types GC and GHC Circuit Breakers
15-100 Amperes, 120, 240, 277,
480Y/277V, 50/60 Hz, 125, 125/250
Vdc, 1, 2, and 3 Poles

Type GC Thermal-Magnetic Circuit Breakers with Non-Interchangeable Trip Units
Continuous
Ampere Rating
@ 40°C

240 Vac Maximum,
125 Vdc Maximum➀

240 Vac Maximum,
125/250 Vdc Maximum

240 Vac Maximum,
125/250 Vdc Maximum➁

1-Pole

2-Pole

3-Pole

Catalog Number

GC1015➂
GC1020➂
GC1025
GC1030
GC1035
GC1040
GC1045
GC1050
GC1060
GC1070
GC1080
GC1090
GC1100

15
20
25
30
35
40
45
50
60
70
80
90
100
Typical GC

These breakers meet the requirements of Federal Specification
W-C-37b as follows:

GC2015➂
GC2020➂
GC2025
GC2030
GC2035
GC2040
GC2045
GC2050
GC2060
GC2070
GC2080
GC2090
GC2100

GC3015➂
GC3020➂
GC3025
GC3030
GC3035
GC3040
GC3045
GC3050
GC3060
GC3070
GC3080
GC3090
GC3100

Type GHC Thermal-Magnetic Circuit Breakers with Non-Interchangeable Trip Units
Continuous
Ampere Rating
@ 40°C

277 Vac Maximum,
125 Vdc Maximum➀

480Y/277 Vac Maximum,
125/250 Vdc Maximum

480Y/277 Vac Maximum,
125/250 Vdc Maximum➁

1-Pole

2-Pole

3-Pole

Catalog Number

Types GC, 120 and 240 Volts:
1 Pole: Class 11a
2, 3 Poles: Classes 10b, 11b, 12b,
14b, 15b

GHC1015➂
GHC1020➂
GHC1025
GHC1030
GHC1035
GHC1040
GHC1045
GHC1050
GHC1060
GHC1070
GHC1080
GHC1090
GHC1100

15
20
25
30
35
40
45
50
60
70
80
90
100

Type GHC, 277 and 480Y/277 Volts:
1 Pole: Classes 12c, 13a
2, 3 Poles: Class 13b

GHC2015➂
GHC2020➂
GHC2025
GHC2030
GHC2035
GHC2040
GHC2045
GHC2050
GHC2060
GHC2070
GHC2080
GHC2090
GHC2100

GHC3015➂
GHC3020➂
GHC3025
GHC3030
GHC3035
GHC3040
GHC3045
GHC3050
GHC3060
GHC3070
GHC3080
GHC3090
GHC3100

Instruction Leaflet/FRED Number 15548

Type GHCGFEP Cable In/Cable Out 30mA Industrial Ground Fault Circuit Protectors
15-60 Amperes, 277 Volt, 50/60 Hz
These circuit breakers meet the
requirements of UL489 and UL1053.
Operational voltage 240V to 305V.
Interrupting Capacity Ratings
Circuit
Breaker
Type

GHCGFEP

Number
of Poles

2

Interrupting Capacity
(Symmetrical Amperes)
277 Volts Ac (50/60 Hz)

14,000

Type GHBGFEP Bolt-on Panelboard 30mA
Industrial Ground Fault Circuit Protectors
with Non-Interchangeable Trip Units
Continuous
Ampere
Rating
@ 40°C

15
20
30
40
50
60

One Phase (Requires 2 Poles)
277V, 30mA
Catalog Number

GHBGFEP1015
GHBGFEP1020
GHBGFEP1030
GHBGFEP1040
GHBGFEP1050
GHBGFEP1060

Instruction Leaflet/FRED Number 29C193

Single Phase
Requires 2 Poles)

➀ 15 through 70 ampere circuit breakers only.
➁ Use (2) outside poles.
➂ Uses .190-32 screw type clamp terminals.

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

Cutler-Hammer

Molded Case Circuit Breakers
15-100 Amperes

March 1999

Series C G-Frame

Special Purpose Breakers
marked “Special purpose breaker
not for general use.” To order this
special breaker, use the catalog
number below.

These are Types GC and GHC circuit
breakers with binding head screwtype terminals on line and load side.
These circuit breakers with screwtype terminals (.190-32) will be

Type GC Thermal-Magnetic Circuit Breakers with Non-Interchangeable Trip Units
Continuous
Ampere Rating
@ 40°C

120 Vac Maximum,
125 Vdc Maximum

240 Vac Maximum,
125/250 Vdc Maximum

240 Vac Maximum,
125/250 Vdc Maximum➀

1-Pole

2-Pole

3-Pole

Catalog Number

GC3025D
GC3030D
GC3035D
GC3040D
GC3045D
GC3050D
GC3055D
GC3060D

GC2025D
GC2030D
GC2035D
GC2040D
GC2045D
GC2050D
GC2055D
GC2060D

GC1025D
GC1030D
GC1035D
GC1040D
GC1045D
GC1050D
GC1055D
GC1060D

25
30
35
40
45
50
55
60

Type GHC Thermal-Magnetic Circuit Breakers with Non-Interchangeable Trip Units
Continuous
Ampere Rating
@ 40°C

277 Vac Maximum,
125 Vdc Maximum

480Y/277 Vac Maximum,
125/250 Vdc Maximum

480Y/277 Vac Maximum,
125/250 Vdc Maximum➀

1-Pole

2-Pole

3-Pole

Catalog Number

25
30
35
40
45
50
55
60

GHC1025D
GHC1030D
GHC1035D
GHC1040D
GHC1045D
GHC1050D
GHC1055D
GHC1060D

Instruction Leaflet/FRED Number 15548

➀ Use (2) outside poles.

PG.74A.01.T.E

GHC2025D
GHC2030D
GHC2035D
GHC2040D
GHC2045D
GHC2050D
GHC2055D
GHC2060D

GHC3025D
GHC3030D
GHC3035D
GHC3040D
GHC3045D
GHC3050D
GHC3055D
GHC3060D

29

30

Cutler-Hammer

Molded Case Circuit Breakers
15-100 Amperes

March 1999

Series C G-Frame

Dimensions/Weights
Dimensions, Inches (mm)
Number of Poles

Width

Height

Depth

1

1.0
(25.33)

4.88
(123.95)

2.81
(71.41)

2

2.0
(50.78)

4.88
(123.95)

2.81
(71.41)

3

3.0
(76)

4.88
(123.95)

2.81
(71.41)

Approximate Shipping Weight, Lbs. (kg)
Breaker Type

Number of Poles
1

2

3

GD

1.0
(.454)

1.5
(.680)

2.25
(1.021)

GHBGFEP

–

1.2
(.545)

–

GHCGFEP

–

1.1
(.499)

–

GB/GHC

GC/GHC

Carton Quantity

24

12

8

16
(7.264)

16
(7.264)

16
(7.264)

Carton Quantity

24

12

8

18
(8.172)

18
(8.172)

18
(8.172)

Accessories
Internal
Alarm Switch . . . . . . . . . . . . . . . .
Auxiliary Switch. . . . . . . . . . . . . .
Shunt Trip . . . . . . . . . . . . . . . . . .
Undervoltage Release
Mechanism . . . . . . . . . . . . . . . .

139
142
147
153

External
Base Mounting Hardware . . . . . .
Base Mounting Plate . . . . . . . . . .
DIN Rail Adapter . . . . . . . . . . . . .
Key Operated Attachment. . . . . .
Lock Dog (non-padlockable) . . . .
Padlockable Handle . . . . . . . . . . .
Handle Mechanisms . . . . . . . . . .

163
167
167
167
168
168
180

PG.74A.01.T.E

Cutler-Hammer
March 1999

Molded Case Circuit Breakers
10-225 Amperes

31

Series C F-Frame

Interrupting Capacity Ratings
UL489 Interrupting Capacity Ratings
Circuit
Breaker
Type

Number of
Poles

Interrupting Capacity (Symmetrical Amperes) (kA)
Volts Ac (50/60 Hz)
240

Typical Series C F-Frame Breaker
■

All Series C F-frame circuit breakers
are HACR rated.

■

All circuit breakers 10 through 50
amperes are suitable for HID (high
intensity discharge) use.

■

All F-frame circuit breakers are
suitable for reverse feed use.

➀ Dc ratings apply to substantially
non-inductive circuits.
➁ 2-pole circuit breaker, or two poles of 3-pole
circuit breaker.
➂ Time constant is 3 milliseconds minimum at
10 kA and 8 milliseconds minimum at 22 kA.

PG.74A.01.T.E

Page
Number

Volts Dc➀

277

480

600

125

250➁➂

ED
EDH
EDC

2, 3
2, 3
2, 3

65
100
200

–
–
–

–
–
–

–
–
–

10
10
10

–
–
–

32
32
32

EHD

1
2, 3

–
18

14
–

–
14

–
–

10
–

–
10

32
32

FDB

2, 3, 4

18

–

14

14

–

10

32

FD

1
2, 3, 4

–
65

25
–

–
25

–
18

10
–

–
10

32
32

HFD

1
2, 3, 4

–
100

65
–

–
65

–
25

10
–

–
22

33
33

FDC

2, 3, 4

200

–

100

35

–

22

33

IEC 157-1 (P1) Interrupting Capacity Ratings (P1)
Circuit
Breaker
Type

Number of
Poles

Interrupting Capacity (Symmetrical Amperes) (kA)
Volts Ac (50/60 Hz)
220, 240

380, 415

440

500

125

65
100
200

–
–
–

–
–
–

–
–
–

2, 3, 4

18

14

14

1
2, 3, 4

25
65

–
35

–
35

HFD

1
2, 3, 4

65
100

–
65

FDC

2, 3, 4

200

100

ED
EDH
EDC

2, 3
2, 3
2, 3

FDB
FD

Page
Number

Volts Dc➀
250➁➂

10
10
10

–
–
–

32
32
32

14

–

10

32

–
18

10
–

–
10

32
32

–
65

–
25

10
–

–
22

33
33

100

35

–

22

33

Time/Current Curves, Dimension Sheets, Application Data

32

Cutler-Hammer

Molded Case Circuit Breakers
10-225 Amperes

March 1999

Series C F-Frame

Types ED, EDH, and EDC Thermal-Magnetic Circuit
Breakers with Non-Interchangeable Trip Units
Suitable for Reverse Feed
Maximum 240 Vac Maximum, 125 Vdc
Continuous
65 kAIC @ 240 Vac
100 kAIC @ 240 Vac
Ampere
Rating
Type ED
Type EDH
@ 40°C
2-Pole

3-Pole

2-Pole

200 kAIC @ 240 Vac
Type EDC Current
Limiting

3-Pole

2-Pole

Type EHD Thermal-Magnetic Circuit Breakers with
Non-Interchangeable Trip Units
Maximum
Continuous
Ampere
Rating
@ 40°C

ED3100
ED3125
ED3150
ED3175
ED3200
ED3225

ED2100
ED2125
ED2150
ED2175
ED2200
ED2225

EDH2100
EDH2125
EDH2150
EDH2175
EDH2200
EDH2225

EDH3100
EDH3125
EDH3150
EDH3175
EDH3200
EDH3225

EDC2100
EDC2125
EDC2150
EDC2175
EDC2200
EDC2225

480 Vac Maximum, 250 Vdc

14 kAIC @ 277 Vac

14 kAIC @ 480 Vac

Type EHD
1-Pole

3-Pole

2-Pole

3-Pole

Catalog Number (Includes Terminals on Load End Only)

Catalog Number (Includes Terminals on Load End Only)

100
125
150
175
200
225

277 Vac Maximum, 125
Vdc

10➀
15
20
25
30
35
40
45
50
60
70
80
90
100

EDC3100
EDC3125
EDC3150
EDC3175
EDC3200
EDC3225

Instruction Leaflet/FRED Number 29C101

EHD2010
EHD2015
EHD2020
EHD2025
EHD2030
EHD2035
EHD2040
EHD2045
EHD2050
EHD2060
EHD2070
EHD2080
EHD2090
EHD2100

EHD1010
EHD1015➁
EHD1020➁
EHD1025
EHD1030
EHD1035
EHD1040
EHD1045
EHD1050
EHD1060
EHD1070
EHD1080
EHD1090
EHD1100

EHD3010
EHD3015
EHD3020
EHD3025
EHD3030
EHD3035
EHD3040
EHD3045
EHD3050
EHD3060
EHD3070
EHD3080
EHD3090
EHD3100

Instruction Leaflet/FRED Number 29C101

Type FD Thermal-Magnetic Circuit Breakers with Non-Interchangeable Trip Units
Maximum
Continuous
Ampere
Rating
@ 40°C

600 Vac Maximum, 250 Vdc

277 Vac Maximum, 125 Vdc

600 Vac Maximum, 250 Vdc

14 kAIC @ 600 Vac

25 kAIC @ 277 Vac

25 kAIC @ 480 Vac

Type FDB
2-Pole

Type FD
3-Pole

4-Pole

1-Pole

2-Pole

3-Pole

4-Pole

Catalog Number (Includes Terminals on Load End Only)

10➀
15
20
25
30
35
40
45
50
60
70
80
90
100
110
125
150
175
200
225

FDB2010
FDB2015
FDB2020
FDB2025
FDB2030
FDB2035
FDB2040
FDB2045
FDB2050
FDB2060
FDB2070
FDB2080
FDB2090
FDB2100
FDB2110
FDB2125
FDB2150
–
–
–

FDB3010
FDB3015
FDB3020
FDB3025
FDB3030
FDB3035
FDB3040
FDB3045
FDB3050
FDB3060
FDB3070
FDB3080
FDB3090
FDB3100
FDB3110
FDB3125
FDB3150
–
–
–

FDB4010
FDB4015
FDB4020
FDB4025
FDB4030
FDB4035
FDB4040
FDB4045
FDB4050
FDB4060
FDB4070
FDB4080
FDB4090
FDB4100
FDB4110
FDB4125
FDB4150
–
–
–

FD1010
FD1015➁
FD1020➁
FD1025
FD1030
FD1035
FD1040
FD1045
FD1050
FD1060
FD1070
FD1080
FD1090
FD1100
FD1110
FD1125
FD1150
–
–
–

–
FD2015
FD2020
FD2025
FD2030
FD2035
FD2040
FD2045
FD2050
FD2060
FD2070
FD2080
FD2090
FD2100
FD2110
FD2125
FD2150
FD2175
FD2200
FD2225

–
FD3015
FD3020
FD3025
FD3030
FD3035
FD3040
FD3045
FD3050
FD3060
FD3070
FD3080
FD3090
FD3100
FD3110
FD3125
FD3150
FD3175
FD3200
FD3225

–
FD4015
FD4020
FD4025
FD4030
FD4035
FD4040
FD4045
FD4050
FD4060
FD4070
FD4080
FD4090
FD4100
FD4110
FD4125
FD4150
FD4175
FD4200
FD4225

Instruction Leaflet/FRED Number 29C101

➀ Not UL listed. 5 kAIC interrupting rating.
➁ UL listed for SWD applications, see NEC
Article 240-83 (d).

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

Cutler-Hammer

Molded Case Circuit Breakers
10-225 Amperes

March 1999

33

Series C F-Frame

Types HFD and FDC Thermal-Magnetic Circuit Breakers with Non-Interchangeable Trip Units
Maximum
Continuous
Ampere
Rating
@ 40°C

600 Vac Maximum, 250 Vdc

277 Vac Maximum, 125 Vdc

600 Vac Maximum, 250 Vdc

65 kAIC @ 277 Vac

65 kAIC @ 480 Vac

100 kAIC @ 480 Vac

Type HFD

Type FDC Current Limiting

1-Pole

2-Pole

3-Pole

4-Pole

2-Pole

3-Pole

4-Pole

Catalog Number (Includes Terminals on Load End Only)

15
20
25
30
35
40
45
50
60
70
80
90
100
110
125
150
175
200
225

HFD1015
HFD1020
HFD1025
HFD1030
HFD1035
HFD1040
HFD1045
HFD1050
HFD1060
HFD1070
HFD1080
HFD1090
HFD1100
HFD1110
HFD1125
HFD1150
–
–
–

HFD2015
HFD2020
HFD2025
HFD2030
HFD2035
HFD2040
HFD2045
HFD2050
HFD2060
HFD2070
HFD2080
HFD2090
HFD2100
HFD2110
HFD2125
HFD2150
HFD2175
HFD2200
HFD2225

HFD3015
HFD3020
HFD3025
HFD3030
HFD3035
HFD3040
HFD3045
HFD3050
HFD3060
HFD3070
HFD3080
HFD3090
HFD3100
HFD3110
HFD3125
HFD3150
HFD3175
HFD3200
HFD3225

Instruction Leaflet/FRED Number 29C101

Molded Case Switches
Molded case switches are used as compact switches in
applications requiring high current switching capabilities.
Molded case switches are constructed of circuit breaker
components and are of the high instantaneous automatic
type. Molded case switches are listed in accordance with
Underwriters Laboratories, Inc., Standard UL 1087.
Maximum
Continuous
Ampere Rating
@ 40°C

480 Vac Maximum, 250 Vdc

600 Vac Maximum, 250 Vdc

Complete Circuit Breaker
with Load Side Terminals Only

Complete Circuit Breaker
with Load Side Terminals Only

Catalog Number

2-Pole
100
150
225

EHD2100K
–
–

FD2100K
FD2150K
FD2225K

EHD3100K
–
–

FD3100K
FD3150K
FD3225K

–
–
–

FD4100K
FD4150K
FD4225K

3-Pole
100
150
225
4-Pole
100
150
225

Note: Molded Case Switches may open above
1800 amperes.
Instruction Leaflet/FRED Number 29C101

PG.74A.01.T.E

HFD4015
HFD4020
HFD4025
HFD4030
HFD4035
HFD4040
HFD4045
HFD4050
HFD4060
HFD4070
HFD4080
HFD4090
HFD4100
HFD4110
HFD4125
HFD4150
HFD4175
HFD4200
HFD4225

FDC2015
FDC2020
FDC2025
FDC2030
FDC2035
FDC2040
FDC2045
FDC2050
FDC2060
FDC2070
FDC2080
FDC2090
FDC2100
FDC2110
FDC2125
FDC2150
FDC2175
FDC2200
FDC2225

FDC3015
FDC3020
FDC3025
FDC3030
FDC3035
FDC3040
FDC3045
FDC3050
FDC3060
FDC3070
FDC3080
FDC3090
FDC3100
FDC3110
FDC3125
FDC3150
FDC3175
FDC3200
FDC3225

FDC4015
FDC4020
FDC4025
FDC4030
FDC4035
FDC4040
FDC4045
FDC4050
FDC4060
FDC4070
FDC4080
FDC4090
FDC4100
FDC4110
FDC4125
FDC4150
FDC4175
FDC4200
FDC4225

34

Cutler-Hammer

Molded Case Circuit Breaker
10-225 Amperes

March 1999

Series C F-Frame

Line and Load Terminals
Line and load terminals provide wire
connecting capabilities for specific
ranges of continuous current ratings
and wire types. Except as noted,
terminals comply with Underwriters
Laboratories, Inc., Standards UL486A
and UL486B. Unless otherwise
specified, F-frame circuit breakers

are factory equipped with load terminals only.
Ordering Information
F-frame circuit breakers and molded
case switches have load terminals
only as standard equipment. When
standard line-end terminals (same as

standard load-end terminals) are
required, add suffix L to the circuit
breaker catalog number. When nonstandard or optional line and/or load
terminals are required, order by
style number. Specify if factory
installation is required.

Line and Load Terminals
Maximum Breaker
Amperes

Terminal Body Material

Wire Type

AWG Wire Range

Metric Wire Range mm2

Package of 3 Terminals
Catalog Number

Standard Pressure Type Terminals
20 (EHD)
100
225

Steel
Steel
Aluminum

Cu/AI
Cu/AI
Cu/AI

#14-#10
#14-1/0
#14-4/0

2.5-4
2.5-50
25-95

3T20FB➀
3T100FB
3TA225FD

Aluminum
Aluminum
Stainless Steel
Aluminum

Cu/AI
Cu/AI
Cu
Cu/AI

#14-#4
#14-1/0
#4-4/0
#6-300 kcmil

2.5-16
2.5-50
25-95
16-150

3TA50FB➀
3TA100FD
3T150FB
3TA225FDK➁

Optional Pressure Terminals
50
100
200
225

Collar

Collar

Screw

Nut
Clip
Conductor

Washer

Conductor

Conductor

Wire Clamp

Screw

3T20FB

3T100FB, 3T150FB

Assemble wire clamp to bottom of conductor as shown.

Insert collar enclosing conductor as
shown. Locate nut on top of conductor
and tighten securely with screw and
washer. Caution: Collar must surround
conductor.

Extrusion

3TA225FD

Insert collar enclosing conductor and center on extrusion on collar. Install clip with
legs on top of conductor and snap end
around bottom of collar.

Collar

Conductor
Collar
Washer
Conductor
Screw

3TA150FB

Assemble collar on top of conductor as
shown. Tighten securely with screw and
washer.

Washer
Screw

3TA100FD

Collar slides onto conductor and is held in
position by a screw and lockwasher.

3TA225FDK

Assemble collar on top of conductor as
shown. Tighten securely with screw and
washer. Terminal shield must be used
with this collar.

➀ Not for use with ED, EDH, EDC breakers.
➁ Includes terminal shield kit. Adds approximately 3 inches to breaker height. Available
for use on 3-pole breaker only.

PG.74A.01.T.E

Cutler-Hammer

Molded Case Circuit Breakers
10-225 Amperes

March 1999

35

Series C F-Frame

Catalog Numbering System
This information is presented only as an aid to understanding catalog numbers. It is not to be used to build catalog
numbers for circuit breakers or trip units.
Circuit Breaker Catalog Number
FDC 3 100 L
Circuit
Breaker
Type

Number
of Poles

Trip
Amperes

EHD
FDB
FD
HFD
FDC

1: 1 Pole
2: 2 Poles
3: 3 Poles
4: 4 Poles

10
E: 100% Protected (4-Pole only) Neutral Pole
15
EH: 50% Protected (4-Pole only)
20
K: High Magnetic Molded
25
Case Switch
30
L: Line and Load Terminals
35
S: Stainless Steel Terminals
40
V: 50˚C Calibration
45
W: Without Terminals
50
Y: Line Terminals Only
60
Z: Aluminum Terminals (≤ 100 Amperes)
70
80
90
100
110
125
150
175 (FD, HFD, FDC, 2-, 3-, 4-Pole Only)
200 (FD, HFD, FDC, 2-, 3-, 4-Pole Only)
225 (FD, HFD, FDC, 2-, 3-, 4-Pole Only)

Suffix

EDC 3 200 L
Circuit
Breaker
Type

Number
of Poles

Trip
Amperes

Suffix

ED
EDH
EDC

2: 2 Poles
3: 3 Poles

100
125
150
175
200
225

L:
W:
Y:
Z:

Line and Load Terminals
Without Terminals
Line Terminals Only
Aluminum Terminals (100 Amperes)

Dimensions/Weights
Dimensions, Inches (mm)
Number of Poles

Width

Approximate Shipping Weight, Lbs. (kg)
Height

Depth

Breaker Type

1

1.375
(35)

6
(152)

3.375
(86)

2

2.75
(70)

6
(152)

3.375
(86)

3

4.125
(105)

6
(152)

3.375
(86)

4

5.5
(140)

6
(152)

3.375
(86)

PG.74A.01.T.E

Number of Poles
1

2

3

4

ED, EDH, EDC

–

3
(1.361)

4.5
(2.041)

–

EHD, FDB, FD,
HFD, FDC

2
(.907)

3
(1.361)

4.5
(2.041)

6
(2.721)

36

Cutler-Hammer

Molded Case Circuit Breakers
10-225 Amperes

March 1999

Series C F-Frame

Allowable Accessory Combinations
Different combinations of accessories can be supplied, depending on the types of accessories and the number of poles
in the circuit breaker.
Reference
Page

1-Pole

2-Pole

3-Pole

Center

Left

Alarm Lockout Switch (Make Only)

139

■

Alarm Lockout (Make/Break)

139

■

❏

❏

■

Alarm Lockout (2Make/2Break)

139

■

❏

❏

■

Right

Left

4-Pole
Center

Right

Left

Center

Right

Neu.

Internal Accessories

Auxiliary Switch (1A, 1B)

142

■

■

■

■

■

Auxiliary Switch (2A, 2B)

142

■

■

■

■

■

■

Auxiliary Switch and Alarm Switch Combination

145

■

❏

❏

Shunt Trip – Standard

148

■

■

■

■

Shunt Trip – Low Energy

152

■

■

■

■

Undervoltage Release Mechanism

154

■

■

■

■

■

External Accessories
End Cap Kit

161

●

●

●

Keeper Nut

161

●

●

●

●

Control Wire Terminal Kit

162

●

●

●

●

Multiwire Connectors

162

●

●

●

●

Base Mounting Hardware

163

●

●

●

●

Terminal Shields

165

●

●

●

●

Terminal End Covers

166

●
●

Interphase Barriers

166

Non-Padlockable Handle Block

168

■

■

Snap-on Padlockable Handle Lock Hasp

168

■

■

Padlockable Handle Lock Hasp

169

Cylinder Lock

169

●

●

■

■

■
■

❏

■
❏

❏

❏

❏

❏

❏

■
■

❏

Key Interlock Kit

170

Sliding Bar Interlock – Requires Two Breakers

171

Walking Beam Interlock – Requires Two Breakers

171

●

●

Electrical (Solenoid) Operator

172

●

●

●

Plug-in Adapters

174

●

●

●

Rear Connecting Studs

175

●

●

●

●

Panelboard Connecting Straps

177

●

●

●

●

Handle Mechanisms

178

●

Door Hardware/Accessories

182

●

LFD Current Limiter

183

●

IQ Energy Sentinel

184

●

●

●

Modifications (Refer to Cutler-Hammer)
Special Calibration

186

●

●

●

●

Moisture Fungus Treatment

186

●

●

●

●

Freeze-Tested Circuit Breakers

186

●

●

●

●

Marine Application

186

●

●

●

■ Applicable in indicated pole position

❏ May be mounted on left or right pole –

●

● Accessory available/Modification available

not both

PG.74A.01.T.E

Cutler-Hammer
March 1999

Molded Case Circuit Breakers
70-250 Amperes

37

Series C J-Frame

Interrupting Capacity Ratings
UL489 Interrupting Capacity Ratings
Circuit
Breaker
Type

Number of
Poles

Interrupting Capacity (Symmetrical Amperes) (kA)
Volts Ac (50/60 Hz)
240

JDB
JD
HJD
JDC

2, 3
2, 3, 4
2, 3, 4
2, 3, 4

65
65
100
200

480

Page
Number

Volts Dc
600

125

10
10
22
22

–
–
–
–

18
18
25
35

35
35
65
100

250➀➁

500➂

–
–
–
–

39
38
38
38

IEC 157-1 (P1) Interrupting Capacity Ratings
Circuit
Breaker
Type

Number of
Poles

Interrupting Capacity (Symmetrical Amperes) (kA)
Volts Ac (50/60 Hz)
240

JD
HJD
JDC

Typical Series C J-Frame Circuit Breaker
■

All Series C J-frame Circuit Breakers
are HACR rated.

■

J-frame circuit breakers are available as individual components
(Frame, Trip Unit, Terminals),
or factory assembled complete
breakers.

■

J-frame circuit breakers with noninterchangeable trip units are
suitable for reverse feed use.

➀ 2-pole circuit breaker or two outside poles
of 3-pole circuit breaker.
➁ Time constant is 3 milliseconds minimum at
10 kA and 8 milliseconds minimum at 22 kA.
➂ 8 milliseconds time constant.

PG.74A.01.T.E

2, 3, 4
2, 3, 4
2, 3, 4

65
100
200

380

35
65
100

Volts Dc
415

35
65
100

600

125

–
–
–

Page
Number

250➀➁

–
–
–

10
22
22

38
38
38

Time/Current Curves, Dimension Sheets, Application Data

38

Cutler-Hammer

Molded Case Circuit Breakers
70-250 Amperes

March 1999

Series C J-Frame

Types JD, HJD, and JDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units
Maximum
Continuous
Ampere
Rating
@ 40°C

Standard Interrupting Capacity
600 Vac Rated
25 kAIC @ 480 Vac
Factory
Assembled
Circuit
Consisting
of Frame,
Trip Unit,
and Terminals

Frame
Only

High Interrupting Capacity
600 Vac Rated
65 kAIC @ 480 Vac
Factory
Assembled
Circuit
Consisting
of Frame,
Trip Unit,
and Terminals

Frame
Only

Ultra High Interrupting
Capacity Current Limiting
600 Vac Rated
100 kAIC @ 480 Vac
Factory
Assembled
Circuit
Consisting
of Frame,
Trip Unit,
and Terminals

Frame
Only

Thermal Magnetic
Trip Unit Only
For Use With: Standard
or High or Ultra High
Interrupting Frames

Standard Terminals Only
See Page 40 for
Optional Terminals

Catalog Number

2-Pole
70
90
100
125
150
175
200
225
250

JD2070
JD2090
JD2100
JD2125
JD2150
JD2175
JD2200
JD2225
JD2250

JD2250F

HJD2070
HJD2090
HJD2100
HJD2125
HJD2150
HJD2175
HJD2200
HJD2225
HJD2250

HJD2250F

JDC2070
JDC2090
JDC2100
JDC2125
JDC2150
JDC2175
JDC2200
JDC2225
JDC2250

JDC2250F

JT2070T
JT2090T
JT2100T
JT2125T
JT2150T
JT2175T
JT2200T
JT2225T
JT2250T

TA250KB➀

JD3070
JD3090
JD3100
JD3125
JD3150
JD3175
JD3200
JD3225
JD3250

JD3250F

HJD3070
HJD3090
HJD3100
HJD3125
HJD3150
HJD3175
HJD3200
HJD3225
HJD3250

HJD3250F

JDC3070
JDC3090
JDC3100
JDC3125
JDC3150
JDC3175
JDC3200
JDC3225
JDC3250

JDC3250F

JT3070T
JT3090T
JT3100T
JT3125T
JT3150T
JT3175T
JT3200T
JT3225T
JT3250T

TA250KB➀

JD4070
JD4090
JD4100
JD4125
JD4150
JD4175
JD4200
JD4225
JD4250

JD4250F

HJD4070
HJD4090
HJD4100
HJD4125
HJD4150
HJD4175
HJD4200
HJD4225
HJD4250

HJD4250F

JDC4070
JDC4090
JDC4100
JDC4125
JDC4150
JDC4175
JDC4200
JDC4225
JDC4250

JDC4250F

JT4070T
JT4090T
JT4100T
JT4125T
JT4150T
JT4175T
JT4200T
JT4225T
JT4250T

TA250KB➀

3-Pole
70
90
100
125
150
175
200
225
250
4-Pole➁➂
70
90
100
125
150
175
200
225
250

Instruction Leaflet/FRED Number 29C103 for Breaker; 29C600 for Thermal Magnetic Trip Unit

➀ Individually packed.
➁ Fully rated neutral pole with no protection.
➂ Neutral is in right pole.

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

Cutler-Hammer

Molded Case Circuit Breakers
70-250 Amperes

March 1999

Series C J-Frame

Type JDB Thermal-Magnetic Circuit Breakers with
Non-Interchangeable Thermal-Magnetic Trip Units
600 Vac Rated, 250 Vdc

Maximum
Continuous
Ampere Rating
@ 40°C

Complete Circuit Breaker
Without Line and
Load Terminals

With Standard Line and Load
Terminals Only

Catalog Number

2-Pole
70
90
100
125
150
175
200
225
250

JDB2070W
JDB2090W
JDB2100W
JDB2125W
JDB2150W
JDB2175W
JDB2200W
JDB2225W
JDB2250W

JDB2070
JDB2090
JDB2100
JDB2125
JDB2150
JDB2175
JDB2200
JDB2225
JDB2250

70
90
100
125
150
175
200
225
250

JDB3070W
JDB3090W
JDB3100W
JDB3125W
JDB3150W
JDB3175W
JDB3200W
JDB3225W
JDB3250W

JDB3070
JDB3090
JDB3100
JDB3125
JDB3150
JDB3175
JDB3200
JDB3225
JDB3250

3-Pole

Instruction Leaflet/FRED Number 29C103 for Breaker

Molded Case Switches
Molded case switches are used as compact switches in
applications requiring high current switching capabilities.
Molded case switches are constructed of circuit breaker
components and are of the high instantaneous automatic
type. Molded case switches are listed in accordance with
Underwriters Laboratories, Inc., Standard UL 1087.
Maximum
Continuous
Ampere Rating
@ 40°C

600 Vac Maximum, 250 Vdc
Complete Circuit Breaker Only Without Line
and Load Terminals
Suitable for Reverse
Feed Use

Standard Terminals
Only
See page 40 for
Optional Terminals

Catalog Number

2-Pole
250

JD2250WK

JDB2250WK

TA250KB➀

JD3250WK

JDB3250WK

TA250KB➀

3-Pole
250

Note: Molded case switches may open above
2500 amperes.
Instruction Leaflet/FRED Number 29C103

➀ Individually packed.

PG.74A.01.T.E

39

40

Cutler-Hammer

Molded Case Circuit Breakers
70-250 Amperes

March 1999

Series C J-Frame

Line and Load Terminals
Line and load terminals provide wire
connecting capabilities for specific
ranges of continuous current ratings
and wire types. All terminals comply
with Underwriters Laboratories, Inc.,
Standards UL486A and UL486B
and CSA Standard C22.2 No. 65,
or Electrical Bulletin 1165. Unless
otherwise specified, J-frame circuit
breaker line and load terminals are
shipped separately for field
installation.

The bottom of the standard
TA250KB terminal contains a recess
which is positioned over the J-frame
circuit breaker terminal conductor.
Ordering Information
J-frame circuit breakers use Cu/AI
terminals as standard. When
optional copper-only terminals are
required, order by catalog number.
Specify if factory installation is
required.

Line and Load Terminals
Maximum
Breaker
Amperes

Terminal Body
Material

Wire Type

AWG Wire Range/
No. Conductors

Metric Wire
Range mm2

#4-350 kcmil
#4-350 kcmil

25-185
25-185

Catalog Numbers

Standard Cu/AI Pressure Terminals
250
250

Aluminum
Stainless Steel

Cu/AI
Cu

TA250KB
T250KB

Collar
Collar

Nut

Slotted
Screw

T250KB Terminal

Slotted
Screw

TA250KB Terminal

PG.74A.01.T.E

Cutler-Hammer

Molded Case Circuit Breakers
70-250 Amperes

March 1999

41

Series C J-Frame

Catalog Numbering System
This information is presented only as an aid to understanding catalog numbers. It is not to be used to build catalog
numbers for circuit breakers or trip units.
Circuit Breaker/Frame Catalog Number
JD 3 250 F

Trip Unit Catalog Number
JT 3 250 T

Circuit
Breaker/
Frame
Type

Number
of Poles

Circuit
Breaker/
Frame
Ampere
Rating

Suffix

Trip Unit
Type

Number
of Poles

Trip Unit/
Rating
Plug
Ampere
Rating

Suffix

JDB
JD
HJD
JDC

2: 2 Poles
3: 3 Poles
4: 4 Poles

70
90
100
125
150
175
200
225
250

C: Non-Aluminum
Terminals
F: Frame Only
K: High Magnetic Molded
Case Switch
V: 50°C Calibration
W: Without Terminals
X: Load Side
Terminals Only
Y: Line Side
Terminals Only

JT:

2
3
4

70
90
100
125
150
175
200
225
250

T:

ThermalMagnetic

Dimensions/Weights
Dimensions, Inches (mm)
Number of Poles

Width

Height

Depth

2, 3

4.125
(105)

10
(255)

4.063
(103)

4

5.5
(140)

10
(254)

4.063
(103)

Approximate Shipping Weight, Lbs. (kg)
Breaker Type

Complete Breaker

Frame Only

Trip Unit➀

Number of Poles
2

3

4

2

3

4

2

3

4

JDB

11.25
(5.103)

12.5
(5.670)

–

–

–

–

–

–

–

JD

11.25
(5.103)

12.5
(5.670)

13.25
(6.010)

9
(4.082)

10
(4.536)

10.5
(4.763)

2
(.907)

2
(.907)

2.25
(1.021)

HJD

11.25
(5.103)

12.5
(5.670)

13.25
(6.010)

9
(4.082)

10
(4.536)

10.5
(4.763)

2
(.907)

2
(.907)

2.25
(1.021)

JDC

12.25
(5.103)

13.5
(6.124)

14.25
(6.470)

10
(4.536)

11
(4.990)

11.5
(5.217)

2
(.907)

2
(.907)

2.25
(1.021)

PG.74A.01.T.E

V:

Trip Unit
Thermal-Magnetic
Fixed Thermal
Adj. Magnetic
50°C Calibration
(Thermal-Magnetic
Trip Units Only)

42

Cutler-Hammer

Molded Case Circuit Breakers
70-250 Amperes

March 1999

Series C J-Frame

Series C J-Frame Allowable Accessory Combinations
Different combinations of accessories can be supplied, depending on the types of accessories and the number of poles
in the circuit breaker.
Reference
Page

2-, 3-Pole
Left

4-Pole
Center

Right

Left

Center

Right

Neu.

Internal Accessories (Only One Internal Accessory Per Pole)
Alarm Lockout (Make/Break)

140

❏

❏

❏

❏

Auxiliary Switch (1A, 1B)

142

■

■

■

■

Auxiliary Switch (2A, 2B)

142

■

■

■

■

Auxiliary Switch and Alarm Switch Combination

145

❏

❏

❏

❏

Shunt Trip – Standard

148

■

■

■

■

Shunt Trip – Low Energy

152

■

■

■

■

Undervoltage Release Mechanism

155

■

■

■

■

External Accessories
End Cap Kit

161

●

●

Plug Nut

161

●

●

Control Wire Terminal Kit

162

●

●

Multiwire Connectors

162

●

●

Base Mounting Hardware

163

●

●

Terminal Shields

165

●

●

Interphase Barriers

166

●

Non-Padlockable Handle Block

168

■

Padlockable Handle Block

168

Padlockable Handle Lock Hasp

169

❏

❏

Cylinder Lock

169

❏

❏

Key Interlock Kit

170

❏

Sliding Bar Interlock – Requires Two Breakers

171

●

Electrical (Solenoid) Operator

172

●

●

Plug-in Adapters

174

●

●

Rear Connecting Studs

176

●

●

Panelboard Connecting Straps

177

●

●

Handle Mechanisms

178

●

●

Door Hardware/Accessories

182

●

●

Handle Extension

182

●

●

IQ Energy Sentinel

184

●

Special Calibration

186

●

●

Moisture Fungus Treatment

186

●

●

Freeze-Tested Circuit Breakers

186

●

●

Marine/Naval Application

186

●

●
■

■

■

❏

❏

❏

❏

❏

Modifications (Refer to Cutler-Hammer)

■ Applicable in indicated pole position

❏ May be mounted on left or right pole –

●
● Accessory available/Modification available

not both

PG.74A.01.T.E

Cutler-Hammer
March 1999

Molded Case Circuit Breakers
70-400 Amperes

43

Series C K-Frame

Interrupting Capacity Ratings
NEMA/UL489/CSA Interrupting Capacity Ratings
Circuit
Breaker
Type

Number of
Poles

Interrupting Capacity (Symmetrical Amperes) (kA)
Volts Ac (50/60Hz)
240

Page
Number

Volts Dc

277

480

600

250➁➂

DK
KDB
KD
HKD

2, 3
2, 3, 4
2, 3, 4
2, 3, 4

65
65
65
100

–
–
–
–

–
35
35
65

–
25
25
35

10
10
10
22

47
47
45, 46, 49
45, 46, 49

KDC
CKD
CHKD

2, 3, 4
3
3

200
65
100

–
–
–

100
35
65

50
25
35

22
10
22

45, 46, 49
48, 50
48, 50

IEC 157-1 (P1) Interrupting Capacity Ratings
Circuit
Breaker
Type

Number of
Poles

Interrupting Capacity (Symmetrical Amperes) (kA)
Volts Ac (50/60Hz)
240

Typical Series C K-Frame Circuit Breaker
■

All Series C K-frame Circuit Breakers
are HACR rated.

■

K-frame circuit breakers are available as individual components
(Frame, Trip Unit, Terminals), or
factory assembled complete
breakers. OPTIM circuit breakers
are available as factory assembled
only.

■

K-frame circuit breakers with noninterchangeable trip units are
suitable for reverse feed use.

➀ Weights shown are for thermal magnetic
trip units. 3-pole electronic trip units weigh
2.5 lbs. (1.134 kg).
➁ 2-pole circuit breaker or two outside poles
of 3-pole circuit breaker.
➂ Time constant is 3 milliseconds minimum at
10 kA and 8 milliseconds minimum at 22 kA.

PG.74A.01.T.E

DK
KDB
KD
HKD
KDC

2, 3
2, 3, 4
2, 3, 4
2, 3, 4
2, 3, 4

65
65
65
100
200

380

–
40
40
65
100

Volts Dc
415

–
40
40
65
100

440

500

–
–
–
–
–

600

–
–
–
–
–

Page
Number

250➂

–
–
–
–
–

10
10
10
22
22

47
47
45, 46, 49
45, 46, 49
45, 46, 49

44

Cutler-Hammer

Molded Case Circuit Breakers
70-400 Amperes

March 1999

Series C K-Frame

K-Frame Digitrip Selection Guide
Trip Unit Type

Digitrip RMS 310

Digitrip OPTIM 550

RMS Sensing

Yes

Yes

Breaker Type
Frame

K

K

70-400A

70-400A

35, 65, 100 (kA)

35, 65, 100 (kA)

Ampere Range
Interrupting Rating at 480V
Protection
Ordering Options

LS, LSG

LSI, LSIG

LSI, LSI(A), LSIG

Fixed Rated Plug (In)

Yes

Yes

Yes

Overtemperature Trip

Yes

Yes

Yes

Long Delay Protection (L)
Adjustable Rating Plug (In)

Yes

Yes

No

Long Delay Pickup

0.5-1.0 (In)➀

0.5-1.0 (In)➀

0.4-1.0 x (In)

Long Delay Time I2T

12 Seconds

12 Seconds

2-24 Seconds

Long Delay Time I4T

No

No

1-5 Seconds

Long Delay Thermal Memory

Yes

Yes

Yes

High Load Alarm

No

No

0.5-1.0 x Ir

Short Delay Protection (S)
Short Delay Pickup

200-800% x (In)

200-800% x (In)

150-800% x (Ir)

Short Delay Time I2T

100 ms

No

100-500 ms

Short Delay Time Flat

No

Inst-300 ms

100-500 ms

Short Delay Time Zone Selective Interlocking

No

No

No

Instantaneous Protection (I)
Instantaneous Pickup

No

200-800% x (In)

200-800% x (In)

Discriminator

No

No

Yes

Instantaneous Override

Yes

Yes

Yes

Ground Fault Protection (G)
Ground Fault Alarm

No

No

20-100% x (Is)

Ground Fault Pickup

Varies by Frame

Varies by Frame

20-100% x (Is)

Ground Fault Delay I2T

No

No

100-500 ms

Ground Fault Delay Flat

Inst-500 ms

Inst-500 ms

100-500 ms

Ground Fault Zone Selective Interlocking

No

No

No

Ground Fault Thermal Memory

Yes

Yes

Yes

Status LEDs

Yes

Yes

Yes

Cause of Trip LEDs

No

No

Yes
Yes

System Diagnostics

Magnitude of Trip Information

No

No

Remote Signal Contact – Ground Alarm

Yes

Yes

No

Local Auxiliary and Bell Alarm Contact

Optional

Optional

Optional

System Monitoring
Digital Display

No

No

Yes➁

Current

No

No

Yes

Power and Energy

No

No

No

Power Quality-Harmonics

No

No

No

Power Factor

No

No

No

No

No

No➂

Communications
Cutler-Hammer PowerNet
Testing
Testing Method
➀ Adjust by rating plug.
➁ By OPTIMizer/BIM.
➂ Cutler-Hammer PowerNet kit for field upgrade.

Test Set
BIM = Breaker Interface Module
(A) = GF Alarm

OPTIMizer, BIM, Cutler-Hammer PowerNet
Is = Sensor Rating
In = Rating Plug
Ir = Long Delay Pickup Setting

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

Cutler-Hammer

Molded Case Circuit Breakers
70-400 Amperes

March 1999

45

Series C K-Frame

Types KD, HKD, and KDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units
Maximum
Continuous
Ampere
Rating
@ 40°C

Standard Interrupting Capacity
600 Vac Rated
35 kAIC @ 480 Vac
Factory
Assembled
Circuit
Consisting
of Frame,
Trip Unit,
and Terminals

Frame
Only

High Interrupting Capacity
600 Vac Rated
65 kAIC @ 480 Vac
Factory
Assembled
Circuit
Consisting
of Frame,
Trip Unit,
and Terminals

Frame
Only

Ultra High Interrupting
Capacity Current Limiting
600 Vac Rated
100 kAIC @ 480 Vac
Factory
Assembled
Circuit
Consisting
of Frame,
Trip Unit,
and Terminals

Frame
Only

Thermal Magnetic
Trip Unit Only
For Use With: Standard
or High or Ultra High
Interrupting Frames

Standard Terminals Only
See Page 51 for
Optional Terminals

Catalog Number

2-Pole
100
125
150
175
200
225
250
300
350
400

KD2100
KD2125
KD2150
KD2175
KD2200
KD2225
KD2250
KD2300
KD2350
KD2400

KD2400F

HKD2100
HKD2125
HKD2150
HKD2175
HKD2200
HKD2225
HKD2250
HKD2300
HKD2350
HKD2400

HKD2400F

KDC2100
KDC2125
KDC2150
KDC2175
KDC2200
KDC2225
KDC2250
KDC2300
KDC2350
KDC2400

KDC2400F

KT2100T
KT2125T
KT2150T
KT2175T
KT2200T
KT2225T
KT2250T
KT2300T
KT2350T
KT2400T

TA300K➀
TA300K➀
TA300K➀
TA300K➀
TA300K➀
TA300K➀
TA350K➀
TA350K➀
TA350K➀
2TA400K➁

KD3100
KD3125
KD3150
KD3175
KD3200
KD3225
KD3250
KD3300
KD3350
KD3400

KD3400F

HKD3100
HKD3125
HKD3150
HKD3175
HKD3200
HKD3225
HKD3250
HKD3300
HKD3350
HKD3400

HKD3400F

KDC3100
KDC3125
KDC3150
KDC3175
KDC3200
KDC3225
KDC3250
KDC3300
KDC3350
KDC3400

KDC3400F

KT3100T
KT3125T
KT3150T
KT3175T
KT3200T
KT3225T
KT3250T
KT3300T
KT3350T
KT3400T

TA300K➀
TA300K➀
TA300K➀
TA300K➀
TA300K➀
TA300K➀
TA350K➀
TA350K➀
TA350K➀
3TA400K➁

KD4100
KD4125
KD4150
KD4175
KD4200
KD4225
KD4250
KD4300
KD4350
KD4400

KD4400F

HKD4100
HKD4125
HKD4150
HKD4175
HKD4200
HKD4225
HKD4250
HKD4300
HKD4350
HKD4400

HKD4400F

KDC4100
KDC4125
KDC4150
KDC4175
KDC4200
KDC4225
KDC4250
KDC4300
KDC4350
KDC4400

KDC4400F

KT3100T
KT3125T
KT3150T
KT3175T
KT3200T
KT3225T
KT3250T
KT3300T
KT3350T
KT3400T

TA300K➀
TA300K➀
TA300K➀
TA300K➀
TA300K➀
TA300K➀
TA350K➀
TA350K➀
TA350K➀
4TA400K➁

3-Pole
100
125
150
175
200
225
250
300
350
400
4-Pole
100
125
150
175
200
225
250
300
350
400

Instruction Leaflet/FRED Number 29C104 for Breaker; 29C603 for Thermal Magnetic Trip Unit

➀ Individually packed.
➁ 2TA400K, 3TA400K, and 4TA400K terminal
kits contain one terminal for each pole and
one terminal cover.

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

46

Cutler-Hammer

Molded Case Circuit Breakers
70-400 Amperes

March 1999

Series C K-Frame

Types KD, HKD, and KDC Electronic Circuit Breakers with Interchangeable Trip Units
Order as individual components: Breaker Frame, Trip Unit, Rating Plug, Terminals.
Maximum
Continuous
Ampere
Rating
@ 40°C➀

Circuit Breaker Frame Only
Standard
Interrupting
Capacity
600 Vac
Rated
35 kAIC @
480 Vac

High
Interrupting
Capacity
600 Vac
Rated
65 kAIC @
480 Vac

Ultra High
Interrupting
Capacity
Current
Limiting
600 Vac Rated
100 kAIC @
480 Vac

Digitrip RMS 310 Trip Unit Only➁

Digitrip 310 Rating Plug Only

Standard

Options

Ampere
Rating

Adjustable
Short Time
Delay with
I2t Short
Delay Ramp

Independently
Adjustable
Short Time
Pickup and
Delay

Adjustable
Short Time
Pickup with
I2t Short
Delay and
Ground Fault
Protection

Independently
Adjustable
Short Time
Pickup and
Delay and
Ground Fault
Protection

Fixed
Rating
Plug

Adjustable
Rating Plugs
Ampere
Rating
Catalog
Number

Standard
Terminals Only
See Page 51
for Optional
Terminals

Catalog Number

3-Pole➂
125

KD3400F

HKD3400F

KDC3400F

KES3125LS

KES3125LSI

KES3125LSG KES3125LSIG

70
90
100
110
125

1KES070T 70/90/100/125
1KES090T A1KES125T1
1KES100T
1KES110T
1KES125T

TA300K➃

250

KD3400F

HKD3400F

KDC3400F

KES3250LS

KES3250LSI

KES3250LSG KES3250LSIG

70
100
125
150
160
175
200
225
250

2KES070T 125/150/200/250
2KES100T A2KES250T1
2KES125T
2KES150T
2KES160T
2KES175T
2KES200T
2KES225T
2KES250T

TA300K➃

400

KD3400F

HKD3400F

KDC3400F

KES3400LS

KES3400LSI

KES3400LSG KES3400LSIG

200
225
250
300
350
400

4KES200T 200/250/300/400
4KES225T A4KES400T1
4KES250T
4KES300T
4KES350T
4KES400T

TA300K➃
TA300K➃
TA300K➃
TA300K➃
TA350K➃
3TA400K➃

125

KD4400F

HKD4400F

KDC4400F

KES4125LS

KES4125LSI

–

–

70
90
100
110
125

1KES070T 70/90/100/125
1KES090T A1KES125T1
1KES100T
1KES110T
1KES125T

TA300K➃

250

KD4400F

HKD4400F

KDC4400F

KES4250LS

KES4250LSI

–

–

70
100
125
150
160
175
200
225
250

2KES070T 125/150/200/250
2KES100T A2KES250T1
2KES125T
2KES150T
2KES160T
2KES175T
2KES200T
2KES225T
2KES250T

TA300K➃

400

KD4400F

HKD4400F

KDC4400F

KES4400LS

KES4400LSI

–

–

200
225
250
300
350
400

4KES200T 200/250/300/400
4KES225T A4KES400T1
4KES250T
4KES300T
4KES350T
4KES400T

TA300K➃
TA300K➃
TA300K➃
TA300K➃
TA350K➃
3TA400K➃

4-Pole➅➆

Instruction Leaflet/FRED Number 29C104 for Breaker; 29C614 for Electronic Trip Unit

➀ Ampere rating is established by rating plug.
➁ For Ac use only.
➂ 3-pole KES Trip Units are for use in 3-pole
frames only.
➃ Individually packed.

➄ 3TA400K and 4TA400K terminal kits contain
one terminal for each pole and one terminal
cover.
➅ Trip unit includes protected neutral pole. Use
corresponding 3-pole trip unit if protected
neutral pole is not required.

➆ Fully rated neutral pole protection is standard. For 50% rated protection on neutral
pole, add suffix E to 4-pole trip unit catalog
number.

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

Cutler-Hammer

Molded Case Circuit Breakers
70-400 Amperes

March 1999

47

Series C K-Frame

Types DK and KDB Thermal-Magnetic Circuit Breakers with Non-Interchangeable Trip Units
Maximum
Continuous
Ampere Rating
@ 40°C

240 Vac Rated, 250 Vdc
Complete Circuit Breaker
Without Line and
Load Terminals

With Line
Terminals Only

With Standard Line
and Load Terminals Only

Maximum
Continuous
Ampere Rating
@ 40°C

600 Vac Rated, 250 Vdc
Complete Circuit Breaker
Without Line and
Load Terminals

With Standard Line
and Load Terminals

Catalog Number

Catalog Number

2-Pole

2-Pole
100
125
150
175
200
225
250
300
350
400

–
–
–
–
–
–
DK2250W
DK2300W
DK2350W
DK2400W

–
–
–
–
–
–
DK2250Y
DK2300Y
DK2350Y
DK2400Y

–
–
–
–
–
–
DK2250
DK2300
DK2350
DK2400

100
125
150
175
200
225
250
300
350
400

–
–
–
–
–
–
DK3250W
DK3300W
DK3350W
DK3400W

–
–
–
–
–
–
DK3250Y
DK3300Y
DK3350Y
DK3400Y

–
–
–
–
–
–
DK3250
DK3300
DK3350
DK3400

100
125
150
175
200
225
250
300
350
400

KDB2100W
KDB2125W
KDB2150W
KDB2175W
KDB2200W
KDB2225W
KDB2250W
KDB2300W
KDB2350W
KDB2400W

KDB2100
KDB2125
KDB2150
KDB2175
KDB2200
KDB2225
KDB2250
KDB2300
KDB2350
KDB2400

100
125
150
175
200
225
250
300
350
400

KDB3100W
KDB3125W
KDB3150W
KDB3175W
KDB3200W
KDB3225W
KDB3250W
KDB3300W
KDB3350W
KDB3400W

KDB3100
KDB3125
KDB3150
KDB3175
KDB3200
KDB3225
KDB3250
KDB3300
KDB3350
KDB3400

3-Pole

3-Pole

Instruction Leaflet/FRED Number 29C104

Molded Case Switches
Molded case switches are used as compact switches in
applications requiring high current switching capabilities.
Molded case switches are constructed of circuit breaker
components and are of the high instantaneous automatic
type. Molded case switches are listed in accordance with
Underwriters Laboratories, Inc., Standard UL 1087.
Maximum
Continuous
Ampere Rating
@ 40°C

240 Vac Maximum,
250 Vdc

600 Vac Maximum,
250 Vdc

600 Vac Maximum,
250 Vdc

Complete Circuit
Breaker with Standard
Line and Load
Terminals

Complete Circuit
Breaker with
Standard Line and
Load Terminals

Complete Circuit
Breaker with Standard
Line and Load
Terminals. Suitable
for Reverse Feed Use

Catalog Number

2-Pole
400

DK2400K

KD2400K

KDB2400K

DK3400K

KD3400K

KDB3400K

–

KD4400K

–

3-Pole
400
4-Pole
400

Note: Molded case switches may open above
4000 amperes.
Instruction Leaflet/FRED Number 29C104

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

48

Cutler-Hammer

Molded Case Circuit Breakers
70-400 Amperes

March 1999

Series C K-Frame

100% Rated Types CKD and CHKD Electronic Circuit Breakers
The NEC allows the breaker to be rated at 100% of its frame size in an assembly, provided that 90°C wire is applied at
the 75°C ampacity. All 100% rated circuit breakers have electronic trip units.
Maximum
Continuous
Ampere
Rating
@ 40°C

Circuit Breaker Frame Only

Digitrip RMS 310 Trip Unit Only

Digitrip 310 Rating Plug Only

Standard
Interrupting
Capacity

High
Interrupting
Capacity

Standard

Options

Ampere
Rating

35 kAIC @
480 Vac

65 kAIC @
480 Vac

Adjustable
Short Time
Delay with
I2t Short
Delay Ramp

Independently
Adjustable
Short Time
Pickup and
Delay

Adjustable
Short Time
Pickup with
I2t Short
Delay and
Ground Fault
Protection

Independently
Adjustable
Short Time
Pickup and
Delay and
Ground Fault
Protection

Fixed
Rating
Plug

Adjustable
Rating Plug
Ampere
Rating
Catalog
Number

Standard
Terminals Only
See Page 51
for Optional
Terminals

Catalog Number

3-Pole
125

CKD3400F

CHKD3400F

KES3125LS

KES3125LSI

KES3125LSG

KES3125LSIG

70
90
100
110
125

1KES070T
1KES090T
1KES100T
1KES110T
1KES125T

70/90/100/125
A1KES125T1

TA300K➃

250

CKD3400F

CHKD3400F

KES3250LS

KES3250LSI

KES3250LSG

KES3250LSIG

70
100
125
150
160
175
200
225
250

2KES070T
2KES100T
2KES125T
2KES150T
2KES160T
2KES175T
2KES200T
2KES225T
2KES250T

125/150/200/250
A2KES250T1

TA300K➃

400

CKD3400F

CHKD3400F

KES3400LS

KES3400LSI

KES3400LSG

KES3400LSIG

200
225
250
300
350
400

4KES200T
4KES225T
4KES250T
4KES300T
4KES350T
4KES400T

200/250/300/400
A4KES400T1

TA300K➃
TA300K➃
TA300K➃
TA300K➃
TA350K➃
3TA400K➃

Instruction Leaflet/FRED Number 29C104 for Breaker; 29C614 for KES Trip Unit

➀ Individually packed.
➁ TA400K, T400K and TA401K terminal kits
contain one terminal for each pole and one
terminal cover.

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

Cutler-Hammer

Molded Case Circuit Breakers
70-400 Amperes

March 1999

49

Series C K-Frame

Digitrip OPTIM 550 Electronic Circuit Breakers with Interchangeable Rating Plug
Order as individual components: Breaker Frame (which includes Trip Unit), Rating Plug, Terminals.
Circuit Breaker Frame Only

Maximum
Continuous
Ampere
Rating
@ 40°C

L
S
I
G
A

Digitrip OPTIM Rating Plug Only

– Adjustable Long Delay Pickup (Ir) with Adjustable Long Delay Time (I2t or I4t Response)➀
– Adjustable Short Delay Pickup with Adjustable Short Delay Time (I 2t or Flat Response)
– Adjustable Instantaneous Pickup
– Adjustable Ground Fault Pickup with Adjustable Ground Fault Time (I 2t or Flat Response)
– Adjustable Ground Fault Alarm with Adjustable Ground Fault Time (I 2t or Flat Response)

Ampere Rating

Fixed Rating Plug

OPTIM 550
LSI

LSIG

LSIA

Catalog Number

3-Pole Standard Interrupting Capacity 600 Volt Ac Rated 35 kAIC @ 480 Vac
125

KD3125T52W

KD3125T56W

KD3125T57W

70
90
100
110
125

ORPK125A070
ORPK125A090
ORPK125A100
ORPK125A110
ORPK125A125

250

KD3250T52W

KD3250T56W

KD3250T57W

125
150
175
200
225
250

ORPK025A125
ORPK025A150
ORPK025A175
ORPK025A200
ORPK025A225
ORPK025A250

400

KD3400T52W

KD3400T56W

KD3400T57W

200
225
250
300
350
400

ORPK40A200
ORPK40A225
ORPK40A250
ORPK40A300
ORPK40A350
ORPK40A400

3-Pole High Interrupting Capacity 600 Volt Ac Rated 65 kAIC @ 480 Vac
125

HKD3125T52W

HKD3125T56W

HKD3125T57W

70
90
100
110
125

ORPK125A070
ORPK125A090
ORPK125A100
ORPK125A110
ORPK125A125

250

HKD3250T52W

HKD3250T56W

HKD3250T57W

125
150
175
200
225
250

ORPK025A125
ORPK025A150
ORPK025A175
ORPK025A200
ORPK025A225
ORPK025A250

400

HKD3400T52W

HKD3400T56W

HKD3400T57W

200
225
250
300
350
400

ORPK40A200
ORPK40A225
ORPK40A250
ORPK40A300
ORPK40A350
ORPK40A400

3-Pole Ultra High Interrupting Capacity Current Limiting 600 Volt Ac Rated 100 kAIC @ 480 Vac
125

KDC3125T52W

KDC3125T56W

KDC3125T57W

70
90
100
110
125

ORPK125A070
ORPK125A090
ORPK125A100
ORPK125A110
ORPK125A125

250

KDC3250T52W

KDC3250T56W

KDC3250T57W

125
150
175
200
225
250

ORPK025A125
ORPK025A150
ORPK025A175
ORPK025A200
ORPK025A225
ORPK025A250

400

KDC3400T52W

KDC3400T56W

KDC3400T57W

200
225
250
300
350
400

ORPK40A200
ORPK40A225
ORPK40A250
ORPK40A300
ORPK40A350
ORPK40A400

Instruction Leaflet/FRED Number 29C104
➀ Long delay I4t response selection limits short
delay time to flat response.

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

50

Cutler-Hammer

Molded Case Circuit Breakers
70-400 Amperes

March 1999

Series C K-Frame

100% Rated Digitrip OPTIM 550 Electronic Circuit Breakers with Interchangeable Rating Plug
Order as individual components: Breaker Frame (which includes Trip Unit), Rating Plug, Terminals.
Circuit Breaker Frame Only

Maximum
Continuous
Ampere
Rating
@ 40°C

L
S
I
G
A

Digitrip OPTIM Rating Plug Only

– Adjustable Long Delay Pickup (Ir) with Adjustable Long Delay Time (I2t or I4t Response)➀
– Adjustable Short Delay Pickup with Adjustable Short Delay Time (I 2t or Flat Response)
– Adjustable Instantaneous Pickup
– Adjustable Ground Fault Pickup with Adjustable Ground Fault Time (I 2t or Flat Response)
– Adjustable Ground Fault Alarm with Adjustable Ground Fault Time (I 2t or Flat Response)

Ampere Rating

Fixed Rating Plug

OPTIM 550
LSI

LSIG

LSIA

Catalog Number

3-Pole Standard Interrupting Capacity 600 Volt Ac Rated 35 kAIC @ 480 Vac
125

CKD3125T52W

CKD3125T56W

CKD3125T57W

70
90
100
110
125

ORPK125A070
ORPK125A090
ORPK125A100
ORPK125A110
ORPK125A125

250

CKD3250T52W

CKD3250T56W

CKD3250T57W

125
150
175
200
225
250

ORPK025A125
ORPK025A150
ORPK025A175
ORPK025A200
ORPK025A225
ORPK025A250

400

CKD3400T52W

CKD3400T56W

CKD3400T57W

200
225
250
300
350
400

ORPK40A200
ORPK40A225
ORPK40A250
ORPK40A300
ORPK40A350
ORPK40A400

3-Pole High Interrupting Capacity 600 Volt AC Rated 65 kAIC @ 480 Vac
125

CHKD3125T52W

CHKD3125T56W

CHKD3125T57W

70
90
100
110
125

ORPK125A070
ORPK125A090
ORPK125A100
ORPK125A110
ORPK125A125

250

CHKD3250T52W

CHKD3250T56W

CHKD3250T57W

125
150
175
200
225
250

ORPK025A125
ORPK025A150
ORPK025A175
ORPK025A200
ORPK025A225
ORPK025A250

400

CHKD3400T52W

CHKD3400T56W

CHKD3400T57W

200
225
250
300
350
400

ORPK40A200
ORPK40A225
ORPK40A250
ORPK40A300
ORPK40A350
ORPK40A400

Instruction Leaflet/FRED Number 29C104

➀ Long delay I4t response selection limits short
delay time to flat response.

PG.74A.01.T.E

Cutler-Hammer

Molded Case Circuit Breakers
70-400 Amperes

March 1999

51

Series C K-Frame

Line and Load Terminals
Line and load terminals provide wire
connecting capabilities for specific
ranges of continuous current ratings
and wire types. All terminals comply
with Underwriters Laboratories, Inc.,
Standards UL486A and UL486B

and CSA Standard C22.2 No. 65,
or Electrical Bulletin 1165. Unless
otherwise specified, K-frame circuit
breaker line and load terminals
are shipped separately for field
installation.

Ordering Information
K-frame circuit breakers use Cu/AI
terminals as standard. When
optional copper or Cu/AI terminals
are required, order by catalog number. Specify if factory installation is
required.

Line and Load Terminals
Maximum Breaker
Amperes

Terminal Body
Material

Wire Type

AWG Wire Range/
No. Conductors

Metric Wire
Range mm2

Terminal
Catalog Number

Figure

Terminals with Control Wire
Termination Catalog Number

Figure

Standard Cu/AI Pressure Terminals
225
350
400

Aluminum
Aluminum
Aluminum

Cu/AI
Cu/AI
Cu/AI

3-350/(1)
250-500/(1)
3/0-250/(2)

35-185
120-240
95-120

TA300K➀
TA350K➀
2TA400K➃
3TA400K➄
4TA400K➅

4
3
2
2
2

–
–
2TA400KCW➃
3TA400KCW➄
4TA400KCW➅

–
–
5
5
5

T300K➀
T350K➀
2T400K➃
3T400K➄
4T400K➅
2TA401K➃
3TA401K➄
4TA401K➅
TA402K

4
3
2
2
2
1
1
1
6

–
–
2T400KCW➃
3T400KCW➄
4T400KCW➅
2TA401KCW➃
3TA401KCW➄
4TA401KCW➅
–

–
–
5
5
5
5
5
5
–

Optional Copper and Cu/AI Pressure Type Terminals
225
350
400

Copper
Copper
Copper

Cu
Cu
Cu

3-350/(1)
250-500/(1)
3/0-250/(2)

35-185
120-240
95-120

400

Aluminum

Cu/AI

400

Aluminum

Cu/AI

2/0-250/(2)
or
2/0-500/(1)
500-750/(1)

70-120
70-240
70-240
300-400

Figure 1. TA401K

Figure 2. TA400K, T400K

Figure 3. TA350K, T350K

Figure 4. TA300K, T300K

Figure 5. T400KCW, TA400KCW, TA401KCW

Figure 6. TA402K

See page 53 for other termination accessories.

➀ Individually packed.
➁ Terminal kits contain one terminal for each
pole and one terminal cover.
➂ Terminal kits contain one terminal for each
pole and three interphase barriers.

PG.74A.01.T.E

➃ 2-Pole Kit.
➄ 3-Pole Kit.
➅ 4-Pole Kit.

52

Cutler-Hammer

Molded Case Circuit Breakers
70-400 Amperes

March 1999

Series C K-Frame

Catalog Numbering System
This information is presented only as an aid to understanding catalog numbers. It is not to be used to build catalog
numbers for circuit breakers or trip units.
Circuit Breaker/Frame Catalog Number
KD 3 400 F

Trip Unit Catalog Number
KT 3 400 T

Circuit
Breaker/
Frame
Type

Number
of Poles

Circuit
Breaker/
Frame
Ampere
Rating

Suffix

Trip Unit
Type

Number
of Poles

Trip Unit/
Rating
Plug
Ampere
Rating

Suffix

DK
DKB
KD
HKD
KDC
CKD
CHKD

2: 2 Poles
3: 3 Poles
4: 4 Poles

100
125
150
175
200
225
250
300
350
400

C: Copper Terminals
E: 50% Protected
Neutral Pole (4-Pole
Electronic Trip Circuit
Breaker Only)
F: Frame Only
K: High Magnetic Molded
Case Switch
W: Without Terminals
X: Load Side
Terminals Only
Y: Line Side
Terminals Only

KT:

2: 2 Poles
3: 3 Poles
4: 4 Poles

70➀
90➀
100
125
150
175
200
225
250
300
350
400

LS:

ThermalMagnetic
KES: Electronic

Electronic Trip Unit
Adjustable Short
Time Delay with I2t
Short Delay Ramp
LSI: Electronic Trip Unit
Independently
Adjustable Short
Time Pickup and
Delay
LSG: Electronic Trip Unit
Adjustable Short
Time Pickup with I2t
Short Delay and
Ground Fault
Protection
LSIG: Electronic Trip Unit
Independently
Adjustable Short
Time Pickup and
Delay and Ground
Fault Protection
V:
50°C Calibration
(Thermal-Magnetic
Trip Units Only)
E:
50% Protected
Neutral Pole
(4-Pole Electronic
Trip Unit Only)
Terminals Only
T:
Trip Unit Only

No Suffix Number
Indicates Standard
Load and Lineside
Terminals

OPTIM Circuit Breaker/Frame Catalog Number
KD 3 125 T5 7 W

Circuit
Breaker/
Frame
Type

Number
of Poles

Circuit
Breaker/
Frame
Ampere
Rating

Trip
Model

Trip
Type

Suffix

KD
HKD
KDC
CKD
CHKD

3: 3 Poles

125
250
400

T5 –
Model
550

2 – LSI
6 – LSIG
7 – LSIA

W: Without
Terminals

Dimensions/Weights
Dimensions, Inches (mm)
Number of Poles

Width

Approximate Shipping Weight, Lbs. (kg)
Height

Depth

Breaker
Type

2, 3

5.5
(140)

10.125
(257)

4.063
(103)

4

7.219
(183)

10.125
(257)

4.063
(103)

Complete Breaker

Frame Only

Trip Unit➀

Number of Poles
2

3

2

3

2

3

DK

10
(4.536)

11.5
(5.216)

–

–

–

–

KDB

10
(4.536)

11.5
(5.216)

–

–

–

–

KD

10
(4.536)

11.5
(5.216)

7.5
(3.402)

8.5
(3.856)

1.5
(.680)

1.5
(.680)

HKD

10
(4.536)

11.5
(5.216)

7.5
(3.402)

8.5
(3.856)

1.5
(.680)

1.5
(.680)

KDC

10
(4.536)

11.5
(5.216)

7.5
(3.402)

8.5
(3.856)

1.5
(.680)

1.5
(.680)

➀ Ampere rating available with electronic trip
unit only.

PG.74A.01.T.E

Cutler-Hammer

Molded Case Circuit Breakers
70-400 Amperes

March 1999

53

Series C K-Frame

Allowable Accessory Combinations
Different combinations of accessories can be supplied, depending on the types of accessories and the number of poles
in the circuit breaker.
Reference
Page

2-Pole➀

3-Pole

Left

Right

Left

4-Pole
Center

Right

Left

Center

Right

Neu.

Internal Accessories (Only One Internal Accessory Per Pole)
Alarm Lockout (Make/Break)

140

Alarm Lockout (2Make/2Break)

140

Auxiliary Switch (1A, 1B)

143

Auxiliary Switch (2A, 2B)

143

Auxiliary Switch (3A, 3B)

143

Auxiliary Switch and Alarm Switch Combination

145

Shunt Trip – Standard

149

Shunt Trip – Low Energy

152

Undervoltage Release Mechanism

156

Cutler-Hammer PowerNet Communications Kit
(OPTIM 550)

160

■
■

■
■

❏
❏
■
■
■
❏
■
■
■

❏
❏
■
■
■
❏
■
■
■
■

■
■
■
■
■
❏
■
■
■

■
■
■
❏
■

External Accessories
End Cap Kit

161

Keeper Nut

161

Control Wire Terminal Kit

162

Multiwire Connectors

162

Base Mounting Hardware

163

Terminal Shields

165

Interphase Barriers

166

Non-Padlockable Handle Block

168

Padlockable Handle Block

168

Padlockable Handle Lock Hasp

169

Cylinder Lock

169

Key Interlock Kit

170

Sliding Bar Interlock – Requires Two Breakers

171

Walking Beam Interlock – Requires Two Breakers

171

Electrical (Solenoid) Operator

172

Plug-in Adapters

174

Rear Connecting Studs

176

Panelboard Connecting Straps

177

Handle Mechanisms

178

Door Hardware/Accessories

182

Handle Extension

182

IQ Energy Sentinel

184

Solid-State (Electronic) Portable Test Kit

184

●
●
●
●
●
●
●

●
●
●
●
●
●
●
■
■

■
■
❏
❏

❏
■

❏
❏
❏

●
●
●
●
●
●
●
■
❏
❏
❏

❏

❏

❏

❏

●

●
●
●
●
●
●
●
●
●
●
●

●
●
●
●
●
●
●
●
●
●

●
●
●
●

●
●
●
●

●
●
●
●

●
●
●
●
●
●

OPTIM System Components 3-Poles
Breaker Interface Module (BIM)

185

Digitrip OPTIMizer

185

Auxiliary Power Module

185

Cutler-Hammer PowerNet Software

185

Modifications (Refer to Cutler-Hammer)
Special Calibration

186

Moisture Fungus Treatment

186

Freeze-Tested Circuit Breakers

186

Marine Application

186

■ Applicable in indicated pole position

❏ May be mounted on left or right pole –
not both

➀ 2-pole breaker supplied in 3-pole frame.
Current carrying parts omitted from
center pole.

PG.74A.01.T.E

● Accessory available/Modification available

54

Molded Case Circuit Breakers

Cutler-Hammer
March 1999

PG.74A.01.T.E

Cutler-Hammer
March 1999

Molded Case Circuit Breakers
125-600 Amperes

55

Series C L-Frame

Interrupting Capacity Ratings
UL489 Interrupting Capacity Ratings➀
Circuit
Number of
Breaker Type Poles

Interrupting Capacity (RMS Symmetrical Amperes) (kA)
Volts Ac (50/60 Hz)
240

277

Page
Number

Volts Dc
480

600

125

250➁➂

500

LDB
LD
CLD
HLD
CHLD➃

2, 3
2, 3, 4
2, 3, 4
2, 3, 4
2, 3, 4

65
65
65
100
100

–
–
–
–
–

35
35
35
65
65

25
25
25
35
35

–
–
–
–
–

22
22
22
25
25

–
–
–
–
–

58
57, 59
58, 61
57, 59
61

LDC
CLDC➃

2, 3, 4
2, 3, 4

200
200

–
–

100
100

50
50

–
–

30
30

–
–

57, 60
62

IEC 947-2 Interrupting Capacity Ratings ➀
Typical Series C L-Frame Circuit Breaker
■

■

■

All Series C L-frame circuit breakers
are HACR rated.
L-frame circuit breakers are available as individual components
(Frame, Trip Unit, Terminals), or
factory assembled complete
breakers. OPTIM circuit breakers
are available as factory assembled
only.
L-frame circuit breakers with noninterchangeable trip units are
suitable for reverse feed use.

➀ Utilization category A circuit breakers.
➁ L/R = 8 milliseconds minimum.
➂ 2-pole circuit breaker or two poles of
3-pole circuit breaker. Incorporating
Thermal-Magnetic trip unit only.
➃ 100% rated breakers

PG.74A.01.T.E

Circuit
Breaker
Type

Number of
Poles

Interrupting Capacity (Symmetrical Amperes) (kA)
Volts Ac (50/60 Hz)
240

Volts Dc

415

690

Page
Number

250➁➂

LDB

2, 3

Icu
Ics

85
85

45
45

20
10

20
10

58

LD

2, 3, 4

Icu
Ics

85
85

45
45

20
10

20
10

57, 59

CLD➃

2, 3, 4

Icu
Ics

85
85

45
45

20
10

20
10

58, 61

HLD

2, 3, 4

Icu
Ics

100
100

70
70

25
13

20
10

57, 59

CHLD➃

2, 3, 4

Icu
Ics

100
100

70
70

25
13

20
10

61

LDC

2, 3, 4

Icu
Ics

200
100

100
75

35
18

20
10

57, 60

CLDC➃

2, 3, 4

Icu
Ics

200
100

100
75

35
18

20
10

62

56

Cutler-Hammer

Molded Case Circuit Breakers
125-600 Amperes

March 1999

Series C L-Frame

L-Frame Digitrip Selection Guide
Trip Unit Type

Digitrip RMS 310

Digitrip OPTIM 550

RMS Sensing

Yes

Yes

Digitrip OPTIM 750

Digitrip OPTIM 1050

Yes

Yes

Breaker Type
Frame

L

L

L

L

300-600A

200-600A

200-600A

200-600A

35, 65, 100 (kA)

35, 65, 100 (kA)

35, 65, 100 (kA)

35, 65, 100 (kA)

Ampere Range
Interrupting Rating @ 480V
Protection
Ordering Options

LS, LSG

LSI, LSIG

LSI, LSI(A), LSIG

LSI(A), LSIG

LSI(A), LSIG

Fixed Rated Plug (In)

Yes

Yes

Yes

Yes

Yes

Overtemperature Trip

Yes

Yes

Yes

Yes

Yes

Long Delay Protection (L)
Adjustable Rating Plug (In)

Yes

Yes

No

No

No

Long Delay Pickup

0.5-1.0 (In)➀

0.5-1.0 (In)➀

0.4-1.0 x (In)

0.4-1.0 x (In)

0.4-1.0 x (In)

Long Delay Time I2T

12 Seconds

12 Seconds

2-24 Seconds

2-24 Seconds

2-24 Seconds

Long Delay Time I4T

No

No

1-5 Seconds

1-5 Seconds

1-5 Seconds

Long Delay Thermal Memory

Yes

Yes

Yes

Yes

Yes

High Load Alarm

No

No

0.5-1.0 x Ir

0.5-1.0 x Ir

0.5-1.0 x Ir

Short Delay Protection (S)
Short Delay Pickup

200-800% x (In)

200-800% x (In)

150-800% x (Ir)

150-800% x (Ir)

150-800% x (Ir)

Short Delay Time I2T

100 ms

No

100-500 ms

100-500 ms

100-500 ms

Short Delay Time Flat

No

Inst-300 ms

100-500 ms

100-500 ms

100-500 ms

Short Delay Time Zone Selective Interlocking

No

No

No

Yes

Yes
200-800% x (In)

Instantaneous Protection (I)
Instantaneous Pickup

No

200-800% x (In)

200-800% x (In)

200-800% x (In)

Discriminator

No

No

Yes

Yes

Yes

Instantaneous Override

Yes

Yes

Yes

Yes

Yes

Ground Fault Protection (G)
Ground Fault Alarm

No

No

20-100% x (Is)

20-100% x (Is)

20-100% x (Is)

Ground Fault Pickup

Varies by Frame

Varies by Frame

20-100% x (Is)

20-100% x (Is)

20-100% x (Is)

Ground Fault Delay I2T

No

No

100-500 ms

100-500 ms

100-500 ms

Ground Fault Delay Flat

Inst-500 ms

Inst-500 ms

100-500 ms

100-500 ms

100-500 ms

Ground Fault Zone Selective Interlocking

No

No

No

Yes

Yes

Ground Fault Thermal Memory

Yes

Yes

Yes

Yes

Yes

Status LEDs

Yes

Yes

Yes

Yes

Yes

Cause of Trip LEDs

No

No

Yes

Yes

Yes

Magnitude of Trip Information

No

No

Yes

Yes

Yes

Remote Signal Contact – Ground Alarm

Yes

Yes

No

Yes

Yes

Local Auxiliary and Bell Alarm Contact

Optional

Optional

Optional

Included

Included

Digital Display

No

No

Yes➁

Yes➁

Yes➁

Current

No

No

Yes

Yes

Yes

Power and Energy

No

No

No

No

Yes

Power Quality-Harmonics

No

No

No

No

Yes

Power Factor

No

No

No

No

Yes

No

No

No➂

Yes

Yes

System Diagnostics

System Monitoring

Communications
Cutler-Hammer PowerNet
Testing
Testing Method

➀ Adjust by rating plug.
➁ By OPTIMizer/BIM.
➂ Cutler-Hammer PowerNet kit for field upgrade.

Test Set

BIM = Breaker Interface Module
(A) = GF Alarm

OPTIMizer, BIM, Cutler-Hammer PowerNet

Is = Sensor Rating
In = Rating Plug
Ir = Long Delay Pickup Setting

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

Cutler-Hammer

Molded Case Circuit Breakers
125-600 Amperes

March 1999

57

Series C L-Frame

Types LD, HLD, and LDC Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units
Maximum
Continuous
Ampere
Rating
@ 40°C

Standard Interrupting Capacity
600 Vac Rated
35 kAIC @ 480 Vac
Factory
Assembled
Circuit
Consisting
of Frame,
Trip Unit,
and Terminals

Frame
Only

High Interrupting Capacity
600 Vac Rated
65 kAIC @ 480 Vac
Factory
Assembled
Circuit
Consisting
of Frame,
Trip Unit,
and Terminals

Frame
Only

Ultra High Interrupting
Capacity Current Limiting
600 Vac Rated
100 kAIC @ 480 Vac
Factory
Assembled
Circuit
Consisting
of Frame,
Trip Unit,
and Terminals

Frame
Only

Standard Terminals Only

Thermal Magnetic
Trip Unit Only
For Use With: Standard
or High or Ultra High
Interrupting Frames

See Page 63 for
Optional Terminals

Magnetic Trip Range
is 5-10 x Continuous
Ampere Rating

Catalog Number

2-Pole
300
350
400
450
500
600

LD2300
LD2350
LD2400
LD2450
LD2500
LD2600

LD2600F

HLD2300
HLD2350
HLD2400
HLD2450
HLD2500
HLD2600

HLD2600F

LDC2300
LDC2350
LDC2400
LDC2450
LDC2500
LDC2600

LDC2600F

LT2300T
LT2350T
LT2400T
LT2450T
LT2500T
LT2600T

TA602LD➀
TA602LD➀
TA602LD➀
TA602LD➀
TA602LD➀
2TA603LDK➁

LD3300
LD3350
LD3400
LD3450
LD3500
LD3600

LD3600F

HLD3300
HLD3350
HLD3400
HLD3450
HLD3500
HLD3600

HLD3600F

LDC3300
LDC3350
LDC3400
LDC3450
LDC3500
LDC3600

LDC3600F

LT3300T
LT3350T
LT3400T
LT3450T
LT3500T
LT3600T

TA602LD➀
TA602LD➀
TA602LD➀
TA602LD➀
TA602LD➀
3TA603LDK➁

LD4300
LD4350
LD4400
LD4450
LD4500
LD4600

LD4600F

HLD4300
HLD4350
HLD4400
HLD4450
HLD4500
HLD4600

HLD4600F

LDC4300
LDC4350
LDC4400
LDC4450
LDC4500
LDC4600

LDC4600F

LT4300T
LT4350T
LT4400T
LT4450T
LT4500T
LT4600T

TA602LD➀
TA602LD➀
TA602LD➀
TA602LD➀
TA602LD➀
4TA603LDK➁

3-Pole
300
350
400
450
500
600
4-Pole➂
300
350
400
450
500
600

Instruction Leaflet/FRED Number 29C105 for Breaker; 29C607 for Thermal Magnetic Trip Unit

Types LD, HLD, and LDC Electronic Circuit Breakers with Interchangeable Trip Units
Order as individual components: Breaker Frame, Trip Unit, Rating Plug, Terminals.
Maximum
Continuous
Ampere
Rating
@ 40°C➀

Circuit Breaker Frame Only
Standard
Interrupting
Capacity
600 Vac
Rated
35 kAIC @
480 Vac

High
Interrupting
Capacity
600 Vac
Rated
65 kAIC @
480 Vac

Ultra High
Interrupting
Capacity
Current
Limiting
600 Vac Rated
100 kAIC @
480 Vac

Digitrip RMS 310 Trip Unit Only➃

Digitrip RMS 310 Rating Plug Only

L – Adjustable Long Delay Pickup (By Adjustable Rating Plug)
S – Adjustable Short Delay Pickup with Fixed Short Delay
Time (I2t Response) or Adjustable Short Delay Time
(Flat Response)
I – Adjustable Instantaneous Pickup by Setting Short Delay
Time to Instantaneous
G – Adjustable Ground Fault Pickup with Adjustable Ground
Fault Delay (Flat Response)

Ampere
Rating

Fixed
Rating
Plug

Adjustable
Rating Plug
Ampere
Rating
Catalog
Number

Standard
Terminals Only
See Page 63
for Optional
Terminals

Catalog Number

3-Pole➂
600

LD3600F

HLD3600F

LDC3600F

LES3600LS

LES3600LSI

LES3600LSG

LES3600LSIG

300
350
400
500
600

6LES300T 300/400/500/600
6LES350T A6LES600T1
6LES400T
6LES500T
6LES600T

TA602LD➀
TA602LD➀
TA602LD➀
TA602LD➀
3TA603LDK➁

LD4600F

HLD4600F

LDC4600F

LES4600LS

LES4600LSI

–

–

300
350
400
500
600

6LES300T 300/400/500/600
6LES350T A6LES600T1
6LES400T
6LES500T
6LES600T

TA602LD➃
TA602LD➃
TA602LD➃
TA602LD➃
4TA603LDK➁

4-Pole➂
600

Instruction Leaflet/FRED Number 29C105 for Breaker; 29C615 for LES Trip Unit

➀ Individually packed.
➁ Terminal kits contain one terminal for each
pole and one terminal cover.

PG.74A.01.T.E

➂ Neutral is in right pole.
➃ For AC use only.

Time/Current Curves, Dimension Sheets, Application Data

58

Cutler-Hammer

Molded Case Circuit Breakers
125-600 Amperes

March 1999

Series C L-Frame

100% Rated Types CLD, CHLD, and CLDC Electronic Circuit Breakers with Interchangeable Trip Units
The NEC allows the breaker to be rated at 100% of its frame size in an assembly, provided that 90°C wire is applied at
the 75°C ampacity. All 100% rated circuit breakers have electronic trip units. Order as individual components: Breaker
Frame, Trip Unit, Rating Plug and Terminals.
Maximum
Continuous
Ampere
Rating
@ 40°C➀

Circuit Breaker Frame Only
Standard
Interrupting
Capacity
600 Vac
Rated
35 kAIC @
480 Vac

High
Interrupting
Capacity
600 Vac
Rated
65 kAIC @
480 Vac

Ultra High
Interrupting
Capacity
Current
Limiting
600 Vac Rated
100 kAIC @
480 Vac

CLDC3600F

Digitrip RMS 310 Trip Unit Only

Digitrip RMS 310 Rating Plug Only

Standard

Options

Ampere
Rating

Adjustable
Short Time
Delay with
I2t Short
Delay Ramp

Independently
Adjustable
Short Time
Pickup and
Delay
Ground Fault
Protection

LES3600LS

LES3600LSI

Adjustable
Short Time
Pickup with
I2t Short
Delay and
Ground Fault
Protection

Independently
Adjustable
Short Time
Pickup and
Delay and
Ground Fault
Protection

LES3600LSG

LES3600LSIG

Fixed
Rating
Plug

Standard
Terminals Only

Adjustable
Rating Plug

See Page 63
for Optional
Terminals

Ampere
Rating
Catalog
Number

Catalog Number

3-Pole
600

CLD3600F

CHLD3600F

300
350
400
500
600

6LES300T 300/400/500/600
6LES350T A6LES600T1
6LES400T
6LES500T
6LES600T

TA602LD➁
TA602LD➁
TA602LD➁
TA602LD➁
3TA603LDK➂

Instruction Leaflet/FRED Number 29C105 for Breaker; 29C615 for LES Trip Unit

Type LDB Thermal-Magnetic Circuit Breakers with
Non-Interchangeable Trip Units
Maximum
Continuous
Ampere Rating

600 Vac Rated, 250 Vdc
Complete Circuit Breaker
Without Line and
Load Terminals

With Standard Line
and Load Terminals Only

Catalog Number

Molded Case Switches
Molded case switches are used as compact switches in
applications requiring high current switching capabilities.
Molded case switches are constructed of circuit breaker
components and are of the high instantaneous automatic
type.➃ Molded case switches are listed in accordance
with Underwriters Laboratories, Inc., Standard UL 1087.

2-Pole
300
350
400
450
500
600

LDB2300W
LDB2350W
LDB2400W
LDB2450W
LDB2500W
LDB2600W

LDB2300
LDB2350
LDB2400
LDB2450
LDB2500
LDB2600

300
350
400
450
500
600

LDB3300W
LDB3350W
LDB3400W
LDB3450W
LDB3500W
LDB3600W

LDB3300
LDB3350
LDB3400
LDB3450
LDB3500
LDB3600

Maximum
Continuous
Ampere Rating
@ 40°C

Instruction Leaflet/FRED Number 29C105 for Breaker

Standard Terminals Only

Circuit Breaker Only
Without Line and Load Terminals

See Page 63 for
Optional Terminals

Catalog Number

2-Pole
600

3-Pole

600 Vac Maximum, 250 Vdc

LD2600WK

2TA603LDK

LD3600WK

3TA603LDK

LD4600WK

4TA603LDK

3-Pole
600
4-Pole
600

Note: Molded Case Switch may trip above 6000 amperes.
Instruction Leaflet/FRED Number 29C105 for Molded Case Switch

➀ Ampere rating is established by rating plug.
➁ Individually packed.
➂ 3TA603LDK and 4TA603LDK terminal kits
contain one terminal for each pole and one
terminal cover.

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

Cutler-Hammer

Molded Case Circuit Breakers
125-600 Amperes

March 1999

59

Series C L-Frame

Digitrip OPTIM➀ Electronic Circuit Breaker with Interchangeable Rating Plug
Order as individual components: Breaker Frame (which includes Trip Unit), Rating Plug, Terminals.
Maximum Circuit Breaker Frame Only
Continuous
Ampere
L – Adjustable Long Delay Pickup (Ir) with Adjustable Long Delay Time (I2t or I4t Response)➁
Rating
S – Adjustable Short Delay Pickup with Adjustable Short Delay Time (I 2t or Flat Response)
@ 40°C
I – Adjustable Instantaneous Pickup
G – Adjustable Ground Fault Pickup with Adjustable Ground Fault Time (I 2t or Flat Response)
A – Adjustable Ground Fault Alarm with Adjustable Ground Fault Time (I 2t or Flat Response)
OPTIM 550
LSI

OPTIM 750
LSIG

LSIA

LSIG

Digitrip OPTIM
Rating Plug Only
Ampere
Rating

Fixed Rating
Plug

OPTIM 1050
LSIA

LSIG

LSIA

Catalog Number

3-Pole Standard Interrupting Capacity 600 Volt Ac Rated 35 kAIC @ 480 Vac
125

–

–

–

LD3125T76W

LD3125T77W

LD3125T106W

LD3125T107W

70
90
100
110
125

ORPL125A070
ORPL125A090
ORPL125A100
ORPL125A110
ORPL125A125

250

–

–

–

LD3250T76W

LD3250T77W

LD3250T106W

LD3250T107W

125
150
175
200
225
250

ORPL025A125
ORPL025A150
ORPL025A175
ORPL025A200
ORPL025A225
ORPL025A250

400

LD3400T52W

LD3400T56W

LD3400T57W

LD3400T76W

LD3400T77W

LD3400T106W

LD3400T107W

200
225
250
300
350
400

ORPL40A200
ORPL40A225
ORPL40A250
ORPL40A300
ORPL40A350
ORPL40A400

600

LD3600T52W

LD3600T56W

LD3600T57W

LD3600T76W

LD3600T77W

LD3600T106W

LD3600T107W

300
350
400
500
600

ORPL60A300
ORPL60A350
ORPL60A400
ORPL60A500
ORPL60A600

3-Pole High Interrupting Capacity 600 Volt Ac Rated 65 kAIC @ 480 Vac
125

–

–

–

HLD3125T76W

HLD3125T77W

HLD3125T106W

HLD3125T107W

70
90
100
110
125

ORPL125A070
ORPL125A090
ORPL125A100
ORPL125A110
ORPL125A125

250

–

–

–

HLD3250T76W

HLD3250T77W

HLD3250T106W

HLD3250T107W

125
150
175
200
225
250

ORPL025A125
ORPL025A150
ORPL025A175
ORPL025A200
ORPL025A225
ORPL025A250

400

HLD3400T52W HLD3400T56W

HLD3400T57W

HLD3400T76W

HLD3400T77W

HLD3400T106W

HLD3400T107W

200
225
250
300
350
400

ORPL40A200
ORPL40A225
ORPL40A250
ORPL40A300
ORPL40A350
ORPL40A400

600

HLD3600T52W HLD3600T56W

HLD3600T57W

HLD3600T76W

HLD3600T77W

HLD3600T106W

HLD3600T107W

300
350
400
500
600

ORPL60A300
ORPL60A350
ORPL60A400
ORPL60A500
ORPL60A600

Instruction Leaflet/FRED Number 29C105 for Breaker; 29C891 for OPTIM Trip Unit

➀ One Form C auxiliary switch and one Form C
bell alarm switch supplied with breaker as
standard, on models 750 and 1050.
➁ Long delay I4t response selection limits short
delay time to flat response.

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

60

Cutler-Hammer

Molded Case Circuit Breakers
125-600 Amperes

March 1999

Series C L-Frame

Digitrip OPTIM➀ Electronic Circuit Breaker with Interchangeable Rating Plug
Order as individual components: Breaker Frame (which includes Trip Unit), Rating Plug, Terminals.
Maximum Circuit Breaker Frame Only
Continuous
Ampere
L – Adjustable Long Delay Pickup (Ir) with Adjustable Long Delay Time (I2t or I4t Response)➁
Rating
S – Adjustable Short Delay Pickup with Adjustable Short Delay Time (I 2t or Flat Response)
@ 40°C
I – Adjustable Instantaneous Pickup
G – Adjustable Ground Fault Pickup with Adjustable Ground Fault Time (I 2t or Flat Response)
A – Adjustable Ground Fault Alarm with Adjustable Ground Fault Time (I 2t or Flat Response)
OPTIM 550
LSI

OPTIM 750
LSIG

LSIA

LSIG

Digitrip OPTIM
Rating Plug Only
Ampere
Rating

Fixed Rating
Plug

OPTIM 1050
LSIA

LSIG

LSIA

Catalog Number

3-Pole Ultra High Interrupting Capacity Current Limiting 600 Volt Ac Rated 100 kAIC @ 480 Vac
125

–

–

–

LDC3125T76W

LDC3125T77W

LDC3125T106W

LDC3125T107W

70
90
100
110
125

ORPL125A070
ORPL125A090
ORPL125A100
ORPL125A110
ORPL125A125

250

–

–

–

LDC3250T76W

LDC3250T77W

LDC3250T106W

LDC3250T107W

125
150
175
200
225
250

ORPL025A125
ORPL025A150
ORPL025A175
ORPL025A200
ORPL025A225
ORPL025A250

400

LDC3400T52W LDC3400T56W

LDC3400T57W

LDC3400T76W

LDC3400T77W

LDC3400T106W

LDC3400T107W

200
225
250
300
350
400

ORPL40A200
ORPL40A225
ORPL40A250
ORPL40A300
ORPL40A350
ORPL40A400

600

LDC3600T52W LDC3600T56W

LDC3600T57W

LDC3600T76W

LDC3600T77W

LDC3600T106W

LDC3600T107W

300
350
400
500
600

ORPL60A300
ORPL60A350
ORPL60A400
ORPL60A500
ORPL60A600

Instruction Leaflet/FRED Number 29C105 for Breaker; 29C891 for OPTIM Trip Unit

➀ One Form C auxiliary switch and one Form C
bell alarm switch supplied with breaker as
standard, on models 750 and 1050.
➁ Long delay I4t response selection limits short
delay time to flat response.

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

Cutler-Hammer

Molded Case Circuit Breakers
125-600 Amperes

March 1999

61

Series C L-Frame

100% Rated Digitrip OPTIM➀ Circuit Breakers with Interchangeable Rating Plug
Order as individual components: Breaker Frame (which includes Trip Unit), Rating Plug, Terminals.
Maximum Circuit Breaker Frame Only
Continuous
Ampere
L – Adjustable Long Delay Pickup (Ir) with Adjustable Long Delay Time (I2t or I4t Response)➁
Rating
S – Adjustable Short Delay Pickup with Adjustable Short Delay Time (I 2t or Flat Response)
@ 40°C
I – Adjustable Instantaneous Pickup
G – Adjustable Ground Fault Pickup with Adjustable Ground Fault Time (I 2t or Flat Response)
A – Adjustable Ground Fault Alarm with Adjustable Ground Fault Time (I 2t or Flat Response)
OPTIM 550
LSI

OPTIM 750
LSIG

LSIA

LSIG

Digitrip OPTIM
Rating Plug Only
Ampere
Rating

Fixed Rating
Plug

OPTIM 1050
LSIA

LSIG

LSIA

Catalog Number

3-Pole Standard Interrupting Capacity 600 Volt Ac Rated 35 kAIC @ 480 Vac
125

–

–

–

CLD3125T76W

CLD3125T77W

CLD3125T106W

CLD3125T107W

70
90
100
110
125

ORPL125A07
ORPL125A09
ORPL125A10
ORPL125A11
ORPL125A125

250

–

–

–

CLD3250T76W

CLD3250T77W

CLD3250T106W

CLD3250T107W

125
150
175
200
225
250

ORPL025A12
ORPL025A15
ORPL025A17
ORPL025A20
ORPL025A22
ORPL025A250

400

CLD3400T52W

CLD3400T56W

CLD3400T57W

CLD3400T76W

CLD3400T77W

CLD3400T106W

CLD3400T107W

200
225
250
300
350
400

ORPL40A200
ORPL40A225
ORPL40A250
ORPL40A300
ORPL40A350
ORPL40A400

600

CLD3600T52W

CLD3600T56W

CLD3600T57W

CLD3600T76W

CLD3600T77W

CLD3600T106W

CLD3600T107W

300
350
400
500
600

ORPL60A300
ORPL60A350
ORPL60A400
ORPL60A500
ORPL60A600

3-Pole High Interrupting Capacity 600 Volt Ac Rated 65 kAIC @ 480 Vac
125

–

–

–

CHLD3125T76W

CHLD3125T77W

CHLD3125T106W CHLD3125T107W

70
90
100
110
125

ORPL125A070
ORPL125A090
ORPL125A100
ORPL125A110
ORPL125A125

250

–

–

–

CHLD3250T76W

CHLD3250T77W

CHLD3250T106W CHLD3250T107W

125
150
175
200
225
250

ORPL025A125
ORPL025A150
ORPL025A175
ORPL025A200
ORPL025A225
ORPL025A250

400

CHLD3400T52W CHLD3400T56W

CHLD3400T57W

CHLD3400T76W

CHLD3400T77W

CHLD3400T106W CHLD3400T107W

200
225
250
300
350
400

ORPL40A200
ORPL40A225
ORPL40A250
ORPL40A300
ORPL40A350
ORPL40A400

600

CHLD3600T52W CHLD3600T56W

CHLD3600T57W

CHLD3600T76W

CHLD3600T77W

CHLD3600T106W CHLD3600T107W

300
350
400
500
600

ORPL60A300
ORPL60A350
ORPL60A400
ORPL60A500
ORPL60A600

Instruction Leaflet/FRED Number 29C105 for Breaker; 29C891 for OPTIM Trip Unit

➀ One Form C auxiliary switch and one Form C
bell alarm switch supplied with breaker as
standard, on models 750 and 1050.
➁ Long delay I4t response selection limits short
delay time to flat response.

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

62

Cutler-Hammer

Molded Case Circuit Breakers
125-600 Amperes

March 1999

Series C L-Frame

100% Rated Digitrip OPTIM➀ Electronic Circuit Breaker with Interchangeable Rating Plug
Order as individual components: Breaker Frame (which includes Trip Unit), Rating Plug, Terminals.
Maximum
Continuous
Ampere
Rating
@ 40°C

Circuit Breaker Frame Only
L
S
I
G
A

Digitrip OPTIM
Rating Plug Only

– Adjustable Long Delay Pickup (Ir) with Adjustable Long Delay Time (I2t or I4t Response)➁
– Adjustable Short Delay Pickup with Adjustable Short Delay Time (I 2t or Flat Response)
– Adjustable Instantaneous Pickup
– Adjustable Ground Fault Pickup with Adjustable Ground Fault Time (I 2t or Flat Response)
– Adjustable Ground Fault Alarm with Adjustable Ground Fault Time (I 2t or Flat Response)

OPTIM 550
LSI

OPTIM 750
LSIG

LSIA

LSIG

Ampere
Rating

Fixed Rating
Plug

OPTIM 1050
LSIA

LSIG

LSIA

Catalog Number

3-Pole Ultra High Interrupting Capacity Current Limiting 600 Volt Ac Rated 100 kAIC @ 480 Vac
125

–

–

–

CLDC3125T76W

CLDC3125T77W

CLDC3125T106W

CLDC3125T107W

70
90
100
110
125

ORPL125A070
ORPL125A090
ORPL125A100
ORPL125A110
ORPL125A125

250

–

–

–

CLDC3250T76W

CLDC3250T77W

CLDC3250T106W

CLDC3250T107W

125
150
175
200
225
250

ORPL025A125
ORPL025A150
ORPL025A175
ORPL025A200
ORPL025A225
ORPL025A250

400

CLDC3400T52W CLDC3400T56W

CLDC3400T57W

CLDC3400T76W

CLDC3400T77W

CLDC3400T106W

CLDC3400T107W

200
225
250
300
350
400

ORPL40A200
ORPL40A225
ORPL40A250
ORPL40A300
ORPL40A350
ORPL40A400

600

CLDC3600T52W CLDC3600T56W

CLDC3600T57W

CLDC3600T76W

CLDC3600T77W

CLDC3600T106W

CLDC3600T107W

300
350
400
500
600

ORPL60A300
ORPL60A350
ORPL60A400
ORPL60A500
ORPL60A600

Instruction Leaflet/FRED Number 29C105 for Breaker; 29C891 for OPTIM Trip Unit

➀ One Form C auxiliary switch and one Form C
bell alarm switch supplied with breaker as
standard, on models 750 and 1050.
➁ Long delay I4t response selection limits short
delay time to flat response.

PG.74A.01.T.E

Cutler-Hammer

Molded Case Circuit Breakers
125-600 Amperes

March 1999

63

Series C L-Frame

Line and Load Terminals
Line and load terminals provide wire
connecting capabilities for specific
ranges of continuous current ratings
and wire types. All terminals comply
with Underwriters Laboratories, Inc.,
Standards UL486A and UL486B
and CSA Standard C22.2 No. 65M.
Unless otherwise specified, L-frame
circuit breaker line and load terminals are shipped separately for field
installation.

The wire connecting terminal is
secured with two pan-head, slotted
screws and lock washers which can
be checked for the correct torque
loading or retightened from the
front of the circuit breaker before
installation of the conductors.
(Applies to all styles.) The circuit
breaker line/load terminal conductors are positioned in the conducting
holes in the wire connecting terminal

and are secured with recessed socket
screws which are tightened to the
correct torque loading from the front
of the circuit breaker.
Ordering Information
L-frame circuit breakers use Cu/AI
terminals as standard. When optional
copper terminals are required, order
by catalog number. Specify if factory
installation is required.

Line and Load Terminals
Maximum Breaker
Amperes

Terminal Body
Material

Wire Type

AWG Wire Range/
Number of Conductors

Metric Wire
Range mm2

Terminal
Catalog Number

Terminals with Control Wire
Termination Catalog Numbers

Standard Cu/AI Pressure Terminals
400

Aluminum

Cu/AI

4/0-600 (1)

120-300

450
500
600

Aluminum
Aluminum
Aluminum

Cu/AI
Cu/AI
Cu/AI

4-4/0 (2)
3/0-350 (2)
400-500 (2)

25-95
95-150
185-240

Cu

250-500 (2)

120-250

Pan-Head
Screws and
Lockwashers

TA450LD or TA602LD
or T602LD Terminal

2TA401LDK– 2-Pole Kit➀
3TA401LDK– 3-Pole Kit➀
4TA401LDK– 4-Pole Kit➀
TA450LD➁
TA602LD➁
2TA603LDK– 2-Pole Kit➀
3TA603LDK– 3-Pole Kit➀
4TA603LDK– 4-Pole Kit➀

–
–
–
–
TA602LDCW
2TA602LDKW
3TA602LDKW
4TA602LDKW

Optional Copper and Cu/AI Pressure Type Terminals
600

Copper

TA401LD or TA603LD
Terminal (Step-Type
Terminal Requires
Terminal Cover and
Warning Label.
See Inset.)

T602LD➁

–

Pan-Head Screws and
Lockwashers (Installed
before Cable Clamping
Screws)

Terminal Cover

Warning Label
Retainer

Circuit Breaker
Line Terminal Cover

➀ Terminal kits contain one terminal for each
pole and one terminal cover.
➁ Individually packed.

PG.74A.01.T.E

Screws

64

Cutler-Hammer

Molded Case Circuit Breaker
125-600 Amperes

March 1999

Series C L-Frame

Catalog Numbering System
This information is presented only as an aid to understanding catalog numbers. It is not to be used to build catalog
numbers for circuit breakers or trip units.
Circuit Breaker/Frame Catalog Number
LD 3 600 F

Thermal-Magnetic Trip Unit Catalog Number
LT 3 400 T

Circuit
Breaker/
Frame
Type

Number
of Poles

Circuit
Breaker/
Frame
Ampere
Rating

Suffix

Trip Unit
Type

Number
of Poles

Trip Unit/
Rating
Plug
Ampere
Rating

Suffix

LDB
LD
HLD
LDC
CLD
CHLD
CLDC

2: 2 Poles
3: 3 Poles
4: 4 Poles

300
350
400
450
500
600

C: Copper Terminals
F: Frame Only
K: High Magnetic Molded
Case Switch
V: 50°C (Thermal-Magnetic Trip Units Only)
W: Without Terminals
X: Load Side
Terminals Only
Y: Line Side
Terminals Only

LT:

2: 2 Poles
3: 3 Poles
4: 4 Poles

300
350
400
450
500
600

T:

OPTIM Circuit Breaker/Frame Catalog Number
LD 3 125 T5 7 W

Circuit
Breaker/
Frame
Type

LD
HLD
LDC
CLD
CHLD
CLDC

Number
of Poles

3: 3 Poles

Circuit
Breaker/
Frame
Ampere
Rating

Trip
Model

125
(Available
on Model
750 and
1050 only)

T5 –
Model 550
T7 –
Model 750
T10 –
Model 1050

Trip
Type

ThermalMagnetic

Trip Unit
Thermal-Magnetic
Fixed Thermal
Adjustable Magnetic
50°C Calibration
(Thermal-Magnetic
Trip Units Only)

V:

Digitrip RMS 310 Trip Unit Catalog Number
LES 3 600 LS P

Suffix

Trip Unit
Type

Number
of Poles

Trip Unit
Ampere
Rating

Suffix

Suffix

LES: Electronic

3: 3 Poles
4: 4 Poles

600

LS
LSI
LSG
LSIG

P: 100% Protected
Neutral on 4-Pole
Trip Unit

2 – LSI
W: Without
(550 only)
Terminals
6 – LSIG
7 – LSIA

250
(Available
on Model
750 and
1050 only)
400
600

Dimensions/Weights
Dimensions, Inches (mm)
Number of Poles

Width

Height

Depth

2, 3

8.25
(210)

10.75
(274)

4.062
(103)

4

11
(279)

10.75
(274)

4.062
(103)

Approximate Shipping Weight, Lbs. (kg)
Breaker
Type

Complete Breaker

Frame Only

Trip Unit

Number of Poles
2

3

4

2

3

4

2

3

4

LD, HLD,
LDC

18
(8.172)

20
(9.080)

25
(11.340)

14
(6.356)

15
(6.810)

20
(9.072)

3
(1.361)

4
(1.814)

5
(2.268)

LDB

18
(8.172)

20
(9.080)

25
(11.340)

–

–

–

–

–

–

PG.74A.01.T.E

Cutler-Hammer

Molded Case Circuit Breakers
125-600 Amperes

March 1999

65

Series C L-Frame

Allowable Accessory Combinations
Different combinations of accessories can be supplied, depending on the types of accessories and the number of poles
in the circuit breaker.
Reference
Page

2-Pole➀, 3-Pole
Left

Center

4-Pole
Right

Left

Center

Right

Neu.➁

Internal Accessories (Only One Internal Accessory Per Pole)➂
Alarm Lockout (Make/Break)

140

Alarm Lockout (2Make/2Break)

140

Auxiliary Switch (1A, 1B)

143

Auxiliary Switch (2A, 2B)

143

Auxiliary Switch (3A, 3B)

143

Auxiliary Switch (1A, 1B) and Alarm Switch Combination

146

Auxiliary Switch (2A, 2B) and Alarm Switch Combination

146

Shunt Trip – Standard➃

149

Shunt Trip – Low Energy➃

152

Undervoltage Release Mechanism➃

157

Cutler-Hammer PowerNet Communications Kit (OPTIM 550)

160

■
■
■
■
■
■
■
■
■
■

■
■
■
■
■
■
■
■
■
■
■

■
■
■
■
■
■
■
■
■
■

■
■
■
■
■
■
■
■
■
■

External Accessories
End Cap Kit

161

Control Wire Terminal Kit

162

Base Mounting Hardware

163

Terminal Shields

165

Interphase Barriers

166

Non-Padlockable Handle Block

168

Padlockable Handle Lock Hasp

169

Key Interlock Kit

170

Sliding Bar Interlock – Requires Two Breakers

171

Walking Beam Interlock – Requires Two Breakers

171

Electrical (Motor) Operator

173

Plug-in Adapters

174

Rear Connecting Studs

176

Panelboard Connecting Straps

177

Handle Mechanisms

178

Door Hardware/Accessories

182

Handle Extension

182

Solid-State (Electronic) Portable Test Kit

184

●
●
●
●
●
■
❏
❏

●
●
●
●
●
■
❏
❏

❏
❏

❏
❏

●
●
●
●
●
●
●
●
●
●

●
●
●
●
●
●
●
●
●

●
●
●
●

●
●
●
●

OPTIM System Components 3-Poles
Ground Fault Alarm Unit

184

Potential Transformer Module

184

Breaker Interface Module (BIM)

185

Digitrip OPTIMizer

185

Auxiliary Power Module

185

Cutler-Hammer PowerNet Software

185

Modifications (Refer to Cutler-Hammer)
Special Calibration

186

Moisture Fungus Treatment

186

Freeze-Tested Circuit Breakers

186

Marine Application

■ Applicable in indicated pole position

186

❏ May be mounted on left or right pole –
not both

➀ 2-pole breaker supplied in 3-pole frame.
Current carrying parts omitted from
center pole.
➁ Refer to Cutler-Hammer for appropriate
neutral pole accessory combinations.
➂ OPTIM models 750 and 1050 are factory
sealed and do not have the right pole space
available for accessories.
➃ Shunt trip and UVR cannot be mounted in
right poles on LES trip units.

PG.74A.01.T.E

● Accessory available/Modification available

66

Molded Case Circuit Breakers

Cutler-Hammer
March 1999

PG.74A.01.T.E

Cutler-Hammer
March 1999

Molded Case Circuit Breakers
300-800 Amperes

67

Series C M-Frame

Interrupting Capacity Ratings
UL489/CSA Interrupting Capacity Ratings➀
Circuit
Breaker
Type

Number of
Poles

Interrupting Capacity (Symmetrical Amperes) (kA)
Volts Ac (50/60 Hz)
240

Volts Dc➁➂

480

600

Page
Number

250

MDL
CMDL

2, 3
2, 3

65
65

50
50

25
25

22
22

69, 70
70

HMDL
CHMDL

2, 3
2, 3

100
100

65
65

35
35

25
25

69, 70
70

IEC 947-2 Interrupting Capacity Ratings➀
Circuit
Breaker
Type

Number of
Poles

Interrupting Capacity – RMS Symmetrical Amperes (kA) I CU = I CS
Volts Ac (50/60 Hz)
240

Typical Series C M-Frame Circuit Breaker
■
■

■

All Series C M-frame circuit breakers
are HACR rated.
MDL-frame circuit breakers are
available as individual components (Frame, Trip Unit, Terminals), or factory assembled
complete breakers.
M-frame circuit breakers with
non-interchangeable trip units
are suitable for reverse feed use.

➀ Utilization category A circuit breakers.
➁ Two poles or two poles of 3-pole circuit
breaker. Thermal-magnetic trip units only,
MDL, HMDL breakers with electronic trip unit
are not DC rated.
➂ Time constant is 3 milliseconds minimum at
10 kA and 8 milliseconds at 22 kA.

PG.74A.01.T.E

Volts Dc➁➂

480

600

Page
Number

250

MDL
CMDL

2, 3
2, 3

85
85

50
50

20
20

20
20

69, 70
70

HMDL
CHMDL

2, 3
2, 3

100
100

65
65

25
25

20
20

69, 70
70

68

Cutler-Hammer

Molded Case Circuit Breakers
300-800 Amperes

March 1999

Series C M-Frame

MDL-Frame Digitrip Selection Guide
Trip Unit Type

Digitrip RMS 310

RMS Sensing

Yes

Breaker Type
Frame

MDL

Ampere Range

400-800A

Interrupting Rating @ 480V

50, 65 (kA)

Protection
LS, LSG

LSI, LSIG

Fixed Rated Plug (In)

Ordering Options

Yes

Yes

Overtemperature Trip

Yes

Yes

Long Delay Protection (L)
Adjustable Rating Plug (In)

Yes

Yes

Long Delay Pickup

0.5-1.0 (In) ➀

0.5-1.0 (In) ➀

Long Delay Time I2T

12 Seconds

12 Seconds

Long Delay Time I4T

No

No

Long Delay Thermal Memory

Yes

Yes

High Load Alarm

No

No
200-800% x (In)

Short Delay Protection (S)
Short Delay Pickup

200-800% x (In)

Short Delay Time I2T

100 ms

No

Short Delay Time Flat

No

Inst-300 ms

Short Delay Time Zone Selective Interlocking

No

No
200-800% x (In)

Instantaneous Protection (I)
Instantaneous Pickup

No

Discriminator

No

No

Instantaneous Override

Yes

Yes

Ground Fault Protection (G)
Ground Fault Alarm

No

No

Ground Fault Pickup

Varies by Frame

Varies by Frame

Ground Fault Delay I2T

No

No

Ground Fault Delay Flat

Inst-500 ms

Inst-500 ms

Ground Fault Zone Selective Interlocking

No

No

Ground Fault Thermal Memory

Yes

Yes

Status LEDs

Yes

Yes

Cause of Trip LEDs

No

No

Magnitude of Trip Information

No

No

Remote Signal Contacts – Ground Alarm

Yes

Yes

Digital Display

No

No

Current

No

No

Power and Energy

No

No

Power Quality – Harmonics

No

No

Power Factor

No

No

No

No

System Diagnostics

System Monitoring

Communications
Cutler-Hammer PowerNet
Testing
Testing Method

➀ Adjust by rating plug.

Test Set

In = Rating Plug

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

Cutler-Hammer

Molded Case Circuit Breakers
300-800 Amperes

March 1999

69

Series C M-Frame

Types MDL and HMDL Thermal-Magnetic Circuit Breakers with Interchangeable Trip Units

Factory
Assembled
Circuit
Consisting
of Frame,
Trip Unit,
and Terminals

Frame
Only

Factory
Assembled
Circuit
Consisting
of Frame,
Trip Unit,
and Terminals

Standard Terminals Only ➀

Thermal Magnetic
Trip Unit Only

High Interrupting Capacity
600 Vac Rated
65 kAIC @ 480 Vac

Standard Interrupting Capacity
600 Vac Rated
50 kAIC @ 480 Vac

Maximum
Continuous
Ampere
Rating
@ 40°C

See Page 72 for
Optional Terminals

For Use With: Standard
or High or Ultra High
Interrupting Frames

Frame
Only

Magnetic Trip Range is 5-10
up through 600A;
4-8 on 700 and 800A x Continuous
Ampere Rating

Catalog Number

2-Pole
300
350
400
450
500
600
700
800

MDL2300
MDL2350
MDL2400
MDL2450
MDL2500
MDL2600
MDL2700
MDL2800

MDL2800F

HMDL2300
HMDL2350
HMDL2400
HMDL2450
HMDL2500
HMDL2600
HMDL2700
HMDL2800

HMDL2800F

MT2300T
MT2350T
MT2400T
MT2450T
MT2500T
MT2600T
MT2700T
MT2800T

TA700MA1
TA700MA1
TA700MA1
TA700MA1
TA700MA1
TA700MA1
TA700MA1
TA800MA2

300
350
400
450
500
600
700
800

MDL3300
MDL3350
MDL3400
MDL3450
MDL3500
MDL3600
MDL3700
MDL3800

MDL3800F

HMDL3300
HMDL3350
HMDL3400
HMDL3450
HMDL3500
HMDL3600
HMDL3700
HMDL3800

HMDL3800F

MT3300T
MT3350T
MT3400T
MT3450T
MT3500T
MT3600T
MT3700T
MT3800T

TA700MA1
TA700MA1
TA700MA1
TA700MA1
TA700MA1
TA700MA1
TA700MA1
TA800MA2

3-Pole

Instruction Leaflet/FRED Number 29C111 for Breaker

Types MDLB and HMDLB Thermal-Magnetic Circuit Breakers with Non-Interchangeable Trip Units
Maximum Continuous
Ampere Rating
@ 40°C

Standard Interrupting Capacity
600 Vac Rated
50 kAIC @ 480 Vac

High Interrupting Capacity
600 Vac Rated
50 kAIC @ 480 Vac

Factory Assembled Circuit
Consisting of Frame, Trip Unit,
and Terminals

Factory Assembled Circuit
Consisting of Frame, Trip Unit,
and Terminals

Standard Terminals Only ➀
See Page 72 for
Optional Terminals

Catalog Number

2-Pole
300
350
400
450
500
600
700
800

MDLB2300
MDLB2350
MDLB2400
MDLB2450
MDLB2500
MDLB2600
MDLB2700
MDLB2800

HMDLB2300
HMDLB2350
HMDLB2400
HMDLB2450
HMDLB2500
HMDLB2600
HMDLB2700
HMDLB2800

TA700MA1
TA700MA1
TA700MA1
TA700MA1
TA700MA1
TA700MA1
TA700MA1
TA800MA2

300
350
400
450
500
600
700
800

MDLB3300
MDLB3350
MDLB3400
MDLB3450
MDLB3500
MDLB3600
MDLB3700
MDLB3800

HMDLB3300
HMDLB3350
HMDLB3400
HMDLB3450
HMDLB3500
HMDLB3600
HMDLB3700
HMDLB3800

TA700MA1
TA700MA1
TA700MA1
TA700MA1
TA700MA1
TA700MA1
TA700MA1
TA800MA2

3-Pole

Instruction Leaflet/FRED Number 29C111 for Breaker

➀ Two terminals are required per pole.

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

70

Cutler-Hammer

Molded Case Circuit Breakers
300-800 Amperes

March 1999

Series C M-Frame

Types MDL and HMDL Electronic Circuit Breakers with Interchangeable Trip Units
Order as Individual Components: Breaker Frame, Trip Unit, Rating Plug, Terminals.
Maximum
Continuous
Ampere
Rating
@ 40°C➀

Circuit Breaker Frame Only
Standard
Interrupting
Capacity
600 Vac
Rated
35 kAIC @
480 Vac

High
Interrupting
Capacity
600 Vac
Rated
65 kAIC @
480 Vac

Digitrip RMS 310 Trip Unit Only➁

Digitrip RMS 310 Rating Plug Only

L – Adjustable Long Delay Pickup (by Adjustable Rating Plug)
S – Adjustable Short Delay Pickup with Fixed Short Delay Time (I 2t
Response) or Adjustable Short Delay Time (Flat Response)
I – Adjustable Instantaneous Pickup by Setting Short Delay Time to
Instantaneous
G – Adjustable Ground Fault Pickup with Adjustable Ground Fault
Delay (Flat Response)

Ampere
Rating

Terminals

Fixed
Rating
Plug

Adjustable
Rating Plugs

8MES400T
8MES500T
8MES600T
8MES700T
8MES800T

400/500/600/800
A8MES800T

Ampere
Rating
Catalog
Number

Catalog Number

3-Pole
800

MDL3800F

HMDL3800F

400
500
600
700
800

MES3800LS
MES3800LSI
MES3800LSG
MES3800LSIG

See Page 72
for Standard
and Optional
Terminals

Instruction Leaflet/FRED Number 29C111 for Breaker; 29C615 for MES Trip Unit

Types MDLB and HMDLB Electronic Circuit Breakers with Non-Interchangeable Trip Units
Maximum
Continuous Ampere
Rating @ 40°C➀

Factory Assembled Circuit Breaker Consisting of Frame and Trip Unit
LS

LSI

LSG

LSIG

Catalog Number

3-Pole Standard Interrupting Capacity 600 Vac Rated 50 kAIC @ 480 Vac
800

MDLB3800T33W

MDLB3800T32W

MDLB3800T35W

MDLB3800T36W

HMDLB3800T32W

HMDLB3800T35W

HMDLB3800T36W

3-Pole High Interrupting Capacity 600 Vac Rated 65 kAIC @ 480 Vac
800

HMDLB3800T33W

Instruction Leaflet/FRED Number 29C111 for Breaker; 29C615 for MES Trip Unit

100% Rated Types CMDL and CHMDL Electronic Circuit Breakers with Non-Interchangeable Trip Units
The NEC allows the breaker to be rated at 100% of its frame size in an assembly, provided that 90°C wire is applied at
the 75°C ampacity. All 100% rated circuit breakers have electronic trip units. Order as individual components: breaker
frame, trip unit, rating plug and terminals.
Maximum
Continuous
Ampere
Rating
@ 40°C➀

Circuit Breaker Frame Only
Standard
Interrupting
Capacity
50 kAIC @
480 Vac

High
Interrupting
Capacity
50 kAIC @
480 Vac

Digitrip RMS 310 Trip Unit Only➁

Digitrip RMS 310 Trip Unit Only

Standard

Options

Ampere
Rating

Adjustable
Short Time
Delay with
I2t Short
Delay Ramp

Independently
Adjustable
Short Time
Pickup and
Delay
Ground Fault
Protection

Adjustable
Short Time
Pickup with
I2t Short
Delay and
Ground Fault
Protection

Independently
Adjustable
Short Time
Pickup and
Ground Fault
Protection

MES3800LSG

MES3800LSIG

Fixed
Rating
Plug

Terminals

Adjustable
Rating Plug
Ampere
Rating
Catalog
Number

Catalog Number

3-Pole
800

CMDL3800F

CHMDL3800F

MES3800LS

MES3800LSI

400
500
600
700
800

8MES400T 400/500/600/800
8MES500T A8MES800T
8MES600T
8MES700T
8MES800T

See Page 72
for Standard
and Optional
Terminals

Instruction Leaflet/FRED Number 29C111 for Breaker; 29C615 for MES Trip Unit

➀ Ampere rating is established by rating plug.
➁ For Ac use only.

PG.74A.01.T.E

Cutler-Hammer

Molded Case Circuit Breakers
300-800 Amperes

March 1999

Series C M-Frame

Molded Case Switches
Molded case switches are used as compact switches in
applications requiring high current switching capabilities.
Molded case switches are constructed of circuit breaker
components and are of the high instantaneous automatic
type. Molded case switches are listed in accordance with
Underwriters Laboratories, Inc., Standard UL 1087.
Maximum Continuous
Ampere Rating
@ 40°C

600 Vac Maximum,
250 Vdc
Circuit Breaker Only without Line and
Load Terminals
Catalog Number

2-Pole
800

MDL2800WK

800

MDL3800WK

3-Pole

Note: Molded case switch may trip above
6000 amperes.
Instruction Leaflet/FRED Number 29C111

PG.74A.01.T.E

71

72

Cutler-Hammer

Molded Case Circuit Breakers
300-800 Amperes

March 1999

Series C M-Frame

Line and Load Terminals
M-Frame circuit breakers use Cu/AI
terminals as standard. When optional
copper or Cu/AI terminals are required,
order by catalog number. Specify if
factory installation is required.

Line and Load Terminals
Maximum Breaker
Amperes

Terminal Body
Material

Wire Type

AWG Wire Range/
No. Conductors

Terminal
Catalog Number

Terminals with Control Wire
Termination Catalog Number

Standard Cu/AI Pressure Terminals
600
800
800

Aluminum
Aluminum
Aluminum

Cu/AI
Cu/AI
Cu/AI

(2) #1-500 kcmil
(3) 3/0-400 kcmil
(2) 500-750 kcmil

TA700MA1
TA800MA2
TA801MA

Cu
Cu

(2) 2/0-500 kcmil
(3) 3/0-300 kcmil

T600MA1
T800MA1

TA700MA1CWT
TA800MA2CWT
TA801MACWT

Optional Copper and Cu/AI Pressure Type Terminals
600
800

Copper
Copper

TA700MA1

TA800MA2

–
–

TA801MA1

PG.74A.01.T.E

Cutler-Hammer

Molded Case Circuit Breakers
300-800 Amperes

March 1999

73

Series C M-Frame

Catalog Numbering System
This information is presented only as an aid to understanding catalog numbers. It is not to be used to build catalog
numbers for circuit breakers or trip units.
Circuit Breaker/Frame Catalog Number
MDL 3 800 F

Thermal-Magnetic Trip Unit Catalog Number
MT 3 800 T

Circuit
Breaker/
Frame
Type

Number
of Poles

Circuit
Breaker/
Frame
Ampere
Rating

Suffix

Trip Unit
Type

Number
of Poles

Trip Unit/
Rating
Plug
Ampere
Rating

Suffix

MDL
HMDL

2: 2 Poles
3: 3 Poles

300➀
350➀
400
450
500
600
700
800

F: Frame Only
K: High Magnetic Molded
Case Switch
V: 50°C (Thermal-Magnetic Trip Units Only)
W: Without Terminals
X: Load Side
Terminals Only
Y: Line Side
Terminals Only

MT:
MES:

2: 2 Poles
3: 3 Poles

300➀
350➀
400
450
500
600
700
800

T:
V:

Dimensions/Weights
Dimensions, Inches (mm)
Number of Poles

Width

2, 3

Height

Depth

8.250
(210)

16.000
(406)

4.062
(103)

Approximate Shipping Weight, Lbs. (kg)
Breaker
Type

Complete Breaker

Frame Only

Trip Unit➀

Number of Poles
2

3

2

3

2

3

MDL, HMDL
(T/M T.U.)

26.5

29

24.5

26

2.5

3

MDL, HMDL
(Elec. T.U.)

–

30

–

26

–

4

➀ Thermal-Magnetic only.

PG.74A.01.T.E

Thermal-Magnetic
50°C (Thermal-Magnetic Trip Units Only)
LS:
Digitrip RMS 310
LSI: Digitrip RMS 310
LSG: Digitrip RMS 310
LSIG: Digitrip RMS 310

74

Cutler-Hammer

Molded Case Circuit Breakers
300-800 Amperes

March 1999

Series C M-Frame

Allowable Accessory Combinations
Different combinations of accessories can be supplied, depending on the types of accessories and the number of poles
in the circuit breaker.
Reference
Page

2-Pole➀

3-Pole

Left

Right

Left

Center

Right

Internal Accessories (Only One Internal Accessory Per Pole)
Alarm Lockout (Make/Break)

140

■

■

■

Alarm Lockout (2Make/2Break)

140

■

■

■

Auxiliary Switch (1A, 1B)

143

■

■

■

Auxiliary Switch (2A, 2B)

143

■

■

■

Auxiliary Switch (3A, 3B)

143

■

■

■

Auxiliary Switch (1A, 1B) and Alarm Switch Combination

146

■

■

■

Auxiliary Switch (2A, 2B) and Alarm Switch Combination

146

■

■

■

Shunt Trip – Standard➂

149

■

■

■

Shunt Trip – Low Energy➂

152

■

■

■

Undervoltage Release Mechanism➂

157

■

■

■

External Accessories
Base Mounting Hardware

163

●

Terminal Shields

165

●

Interphase Barriers

166

●

Non-Padlockable Handle Block

168

Padlockable Handle Lock Hasp

169

❏

❏

Key Interlock Kit

170

❏

❏

Sliding Bar Interlock – Requires Two Breakers

171

●

●

Walking Beam Interlock – Requires Two Breakers

171

●

●

Electrical (Motor) Operator

173

●

●

Plug-in Adapters

174

●

●

Rear Connecting Studs

176

●

●

Panelboard Connecting Straps

177

●

●

Handle Mechanisms

178

●

●

Door Hardware/Accessories

182

●

●

Handle Extension

182

Solid-State (Electronic) Portable Test Kit

184

●

●

Special Calibration

186

●

●

Moisture Fungus Treatment

186

●

●

Freeze-Tested Circuit Breakers

186

●

●

Marine Application

186

●

●

■
❏
❏

●

Modifications (Refer to Cutler-Hammer)

■ Applicable in indicated pole position

❏ May be mounted on left or right pole –

● Accessory available/Modification available

not both

➀ 2-pole breaker supplied in 3-pole frame. Current carrying parts omitted from center pole.
➁ Refer to Cutler-Hammer for appropriate
neutral pole accessory combinations.
➂ Shunt trip and UVR cannot be mounted in
right poles on LES trip units.

PG.74A.01.T.E

Cutler-Hammer

Molded Case Circuit Breakers
400-1200 Amperes

March 1999

75

Series C N-Frame

Interrupting Capacity Ratings
UL489 Interrupting Capacity Ratings➀
Number
of Poles

Circuit
Breaker
Type

Interrupting Capacity (Symmetrical Amperes) (kA)

Page
Number

Volts Ac (50/60 Hz)
240

277

480

600

125

ND
CND➁

2, 3, 4
2, 3, 4

65
65

–
–

50
50

25
25

–
–

77, 83
80, 84

HND
CHND➁

2, 3, 4
2, 3, 4

100
100

–
–

65
65

35
35

–
–

78, 83
81, 84

NDC
CNDC➁

2, 3, 4
2, 3, 4

200
200

–
–

100
100

50
50

–
–

79, 83
82, 84

IEC 947-2 Interrupting Capacity Ratings➀
Number of
Poles

Circuit
Breaker
Type

Interrupting Capacity (Symmetrical Amperes) (kA)

240

ND

■

All N-frame circuit breakers are
suitable for reverse feed use.

CND➁

77, 83
85
85

50
50

20
10

85
85

50
50

20
10

100
100

70
50

25
13

100
100

70
50

25
13

200
100

100
50

35
18

200
100

100
50

35
18

80, 84

2, 3, 4
Icu
Ics

CHND➁

78, 83

81, 84

2, 3, 4
Icu
Ics

NDC

79, 83

2, 3, 4
Icu
Ics

CNDC➁

2, 3, 4
Icu
Ics

PG.74A.01.T.E

690

2, 3, 4
Icu
Ics

HND

➀ Utilization Category A circuit breakers.
➁ 100% rated breakers.

415

2, 3, 4
Icu
Ics

Typical Series C N-Frame Circuit Breaker

Page
Number

Volts Ac (50/60 Hz)

82, 84

76

Cutler-Hammer

Molded Case Circuit Breakers
400-1200 Amperes

March 1999

Series C N-Frame

N-Frame Digitrip Selection Guide
Trip Unit Type

Digitrip RMS 310

Digitrip OPTIM 550

Digitrip OPTIM 750

Digitrip OPTIM 1050

RMS Sensing

Yes

Yes

Yes

Yes

Breaker Type
Frame

N

N

N

N

400A-1200A

400A-1200A

400A-1200A

400A-1200A

50, 65, 100 (kA)

50, 65, 100 (kA)

50, 65, 100 (kA)

50, 65, 100 (kA)

Ampere Range
Interrupting Rating @ 480V
Protection
Ordering Options

LS, LSG

LSI, LSIG

LSI, LSIG, LSI(A)

LSI(A), LSIG

LSI(A), LISG

Fixed Rated Plug (In)

Yes

Yes

Yes

Yes

Yes

Overtemperature Trip

Yes

Yes

Yes

Yes

Yes

Long Delay Protection (L)
Yes

Yes

No

No

No

Long Delay Pickup

Adjustable Rating Plug (In)

0.5-1.0 (In)➀

0.5-1.0 (In)➀

0.4-1.0 x (In)

0.4-1.0 x (In)

0.4-1.0 x (In)

Long Delay Time I2T

12 Seconds

12 Seconds

2-24 Seconds

2-24 Seconds

2-24 Seconds

Long Delay Time I4T

No

No

1-5 Seconds

1-5 Seconds

1-5 Seconds

Long Delay Thermal Memory

Yes

Yes

Yes

Yes

Yes

High Load Alarm

No

No

No

0.5-1.0 x Ir

0.5-1.0 x Ir

Short Delay Protection (S)
Short Delay Pickup

200-800% x (In)

200-800% x (In)

150-800% x (Ir)

150-800% x (Ir)

150-800% x (Ir)

Short Delay Time I2T

100 ms

No

100-500 ms

100-500 ms

100-500 ms

Short Delay Time Flat

No

Inst-300 ms

100-500 ms

100-500 ms

100-500 ms

Short Delay Time Zone Selective Interlocking

No

No

Yes

Yes

Yes

Instantaneous Protection (I)
Instantaneous Pickup

No

200-800% x (In)

200-800% x (In)

200-800% x (In)

200-800% x (In)

Discriminator

No

No

Yes

Yes

Yes

Instantaneous Override

Yes

Yes

Yes

Yes

Yes

No

No

Ground Fault Protection (G)
Ground Fault Alarm
Ground Fault Pickup

Varies by Frame➁ Varies by Frame➁

20-100% x (Is)

20-100% x (Is)

20-100% x (Is)

20-100% x (Is)

20-100% x (Is)

20-100% x (Is)

Ground Fault Delay I2T

No

No

100-500 ms

100-500 ms

100-500 ms

Ground Fault Delay Flat

Inst-500 ms

Inst-500 ms

100-500 ms

100-500 ms

100-500 ms

Ground Fault Zone Selective Interlocking

No

No

No

Yes

Yes

Ground Fault Thermal Memory

Yes

Yes

Yes

Yes

Yes

Status LEDs

Yes

Yes

Yes

Yes

Yes

Cause of Trip LEDs

No

No

Yes

Yes

Yes
Yes

System Diagnostics

Magnitude of Trip Information

No

No

Yes

Yes

Remote Signal Contact – Ground Alarm

Yes

Yes

No

Yes

Yes

Local Auxiliary and Bell Alarm Contact

Optional

Optional

Optional

Included

Included

Digital Display

No

No

Yes➁

Yes➁

Yes➁

Current

No

No

Yes

Yes

Yes

Power and Energy

No

No

No

No

Yes

Power Quality-Harmonics

No

No

No

No

Yes

Power Factor

No

No

No

No

Yes

No

No

No➂

Yes

Yes

OPTIMizer, BIM, CutlerHammer PowerNet

OPTIMizer, BIM, CutlerHammer PowerNet

OPTIMizer, BIM, CutlerHammer PowerNet

System Monitoring

Communications
Cutler-Hammer PowerNet
Testing
Testing Method

➀ Adjust by rating plug.
➁ By OPTIMizer/BIM.
➂ Cutler-Hammer PowerNet kit for field upgrade.

Test Set

BIM = Breaker Interface Module
(A) = GF Alarm

Is = Sensor Rating
In = Rating Plug
Ir = Long Delay Pickup Setting

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

Cutler-Hammer

Molded Case Circuit Breakers
400-1200 Amperes

March 1999

77

Series C N-Frame

Type ND Electronic Circuit Breakers with Non-Interchangeable Trip Units
Order as individual components: Breaker Frame, Rating Plug, Terminals
Maximum
Continuous
Ampere
Rating
@ 40°C

Digitrip RMS 310 Circuit Breaker Frame Only

Digitrip RMS 310 Rating Plug Only

Standard Interrupting Capacity
600 Volt Ac Rated 50 kAIC @ 480 Vac

Ampere
Rating

Standard

Options

Adjustable
Short Time
Delay with I2t
Short Delay
Ramp

Independently
Adjustable
Short Time
Pickup and
Delay

Adjustable
Short Time
Pickup with I2t
Short Delay and
Ground Fault
Protection

Fixed
Rating
Plugs

Independently
Adjustable
Short Time
Pickup and
Delay and
Ground Fault
Protection

Standard Terminals Only➀
Adjustable Rating Plug

See Page 85 for
Optional Terminals

Adjustable Ampere Ratings
Catalog Number

Catalog Number

2-Pole
800

ND2800T33W

ND2800T32W

ND2800T35W

ND2800T36W

400
450
500
600
700
800

8NES400T
8NES450T
8NES500T
8NES600T
8NES700T
8NES800T

Adjustable Settings are:
400, 500, 600, 800
A8NES800T1

TA700NB1
TA700NB1
TA700NB1
TA700NB1
TA700NB1
TA1000NB1

ND3800T33W

ND3800T32W

ND3800T35W

ND3800T36W

400
450
500
600
700
800

8NES400T
8NES450T
8NES500T
8NES600T
8NES700T
8NES800T

Adjustable Settings are:
400, 500, 600, 800
A8NES800T1

TA700NB1
TA700NB1
TA700NB1
TA700NB1
TA700NB1
TA1000NB1

ND4800T33W

ND4800T32W

–

–

400
450
500
600
700
800

8NES400T
8NES450T
8NES500T
8NES600T
8NES700T
8NES800T

Adjustable Settings are:
400, 500, 600, 800
A8NES800T1

TA700NB1
TA700NB1
TA700NB1
TA700NB1
TA700NB1
TA1000NB1

ND212T33W

ND212T32W

ND212T35W

ND212T36W

600
700
800
900
1000
1200

12NES600T
12NES700T
12NES800T
12NES900T
12NES1000T
12NES1200T

Adjustable Settings are:
600, 800, 1000, 1200
A12NES1200T1

TA700NB1
TA700NB1
TA1000NB1
TA1000NB1
TA1000NB1
TA1200NB1

ND312T33W

ND312T32W

ND312T35W

ND312T36W

600
700
800
900
1000
1200

12NES600T
12NES700T
12NES800T
12NES900T
12NES1000T
12NES1200T

Adjustable Settings are:
600, 800, 1000, 1200
A12NES1200T1

TA700NB1
TA700NB1
TA1000NB1
TA1000NB1
TA1000NB1
TA1200NB1

ND412T33W

ND412T32W

–

–

600
700
800
900
1000
1200

12NES600T
12NES700T
12NES800T
12NES900T
12NES1000T
12NES1200T

Adjustable Settings are:
600, 800, 1000, 1200
A12NES1200T1

TA700NB1
TA700NB1
TA1000NB1
TA1000NB1
TA1000NB1
TA1200NB1

3-Pole
800

4-Pole➁
800

2-Pole
1200

3-Pole
1200

4-Pole➁
1200

Instruction Leaflet/FRED Number 29C106

➀ Two terminals are required per pole.
➁ Neutral is in right pole.

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

78

Cutler-Hammer

Molded Case Circuit Breakers
400-1200 Amperes

March 1999

Series C N-Frame

Type HND Electronic Circuit Breakers with Non-Interchangeable Trip Units
Order as individual components: Breaker Frame, Rating Plug, Terminals
Maximum
Continuous
Ampere
Rating
@ 40°C

Digitrip RMS 310 Circuit Breaker Frame Only

Digitrip RMS 310 Rating Plug Only

High Interrupting Capacity
600 Volt Ac Rated 65 kAIC @ 480 Vac

Ampere
Rating

Standard

Options

Adjustable
Short Time
Delay with I2t
Short Delay
Ramp

Independently
Adjustable
Short Time
Pickup and
Delay

Adjustable
Short Time
Pickup with I2t
Short Delay and
Ground Fault
Protection

Fixed
Rating
Plugs

Independently
Adjustable
Short Time
Pickup and
Delay and
Ground Fault
Protection

Standard Terminals Only➀
Adjustable Rating Plug

See Page 85 for
Optional Terminals

Adjustable Ampere Ratings
Catalog Number

Catalog Number

2-Pole
800

HND2800T33W HND2800T32W HND2800T35W HND2800T36W

400
450
500
600
700
800

8NES400T
8NES450T
8NES500T
8NES600T
8NES700T
8NES800T

Adjustable Settings are:
400, 500, 600, 800
A8NES800T1

TA700NB1
TA700NB1
TA700NB1
TA700NB1
TA700NB1
TA1000NB1

HND3800T33W HND3800T32W HND3800T35W HND3800T36W

400
450
500
600
700
800

8NES400T
8NES450T
8NES500T
8NES600T
8NES700T
8NES800T

Adjustable Settings are:
400, 500, 600, 800
A8NES800T1

TA700NB1
TA700NB1
TA700NB1
TA700NB1
TA700NB1
TA1000NB1

HND4800T33W HND4800T32W

8NES400T
8NES450T
8NES500T
8NES600T
8NES700T
8NES800T

Adjustable Settings are:
400, 500, 600, 800
A8NES800T1

TA700NB1
TA700NB1
TA700NB1
TA700NB1
TA700NB1
TA1000NB1

3-Pole
800

4-Pole➁
800

–

–

400
450
500
600
700
800

2-Pole
1200

HND212T33W

HND212T32W

HND212T35W

HND212T36W

600
700
800
900
1000
1200

12NES600T
12NES700T
12NES800T
12NES900T
12NES1000T
12NES1200T

Adjustable Settings are:
600, 800, 1000, 1200
A12NES1200T1

TA700NB1
TA700NB1
TA1000NB1
TA1000NB1
TA1000NB1
TA1200NB1

HND312T33W

HND312T32W

HND312T35W

HND312T36W

600
700
800
900
1000
1200

12NES600T
12NES700T
12NES800T
12NES900T
12NES1000T
12NES1200T

Adjustable Settings are:
600, 800, 1000, 1200
A12NES1200T1

TA700NB1
TA700NB1
TA1000NB1
TA1000NB1
TA1000NB1
TA1200NB1

HND412T33W

HND412T32W

–

–

600
700
800
900
1000
1200

12NES600T
12NES700T
12NES800T
12NES900T
12NES1000T
12NES1200T

Adjustable Settings are:
600, 800, 1000, 1200
A12NES1200T1

TA700NB1
TA700NB1
TA1000NB1
TA1000NB1
TA1000NB1
TA1200NB1

3-Pole
1200

4-Pole➁
1200

Instruction Leaflet/FRED Number 29C106

➀ Two terminals are required per pole.
➁ Neutral is in right pole.

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

Cutler-Hammer

Molded Case Circuit Breakers
400-1200 Amperes

March 1999

79

Series C N-Frame

Type NDC Electronic Circuit Breakers with Non-Interchangeable Trip Units
Order as individual components: Breaker Frame, Rating Plug, Terminals
Maximum
Continuous
Ampere
Rating
@ 40°C

Digitrip RMS 310 Circuit Breaker Frame Only

Digitrip RMS 310 Rating Plug Only

Ultra High Interrupting Capacity
600 Volt Ac Rated 100 kAIC @ 480 Vac

Ampere
Rating

Standard

Options

Adjustable
Short Time
Delay with I2t
Short Delay
Ramp

Independently
Adjustable
Short Time
Pickup and
Delay

Adjustable
Short Time
Pickup with I2t
Short Delay and
Ground Fault
Protection

Fixed
Rating
Plugs

Independently
Adjustable
Short Time
Pickup and
Delay and
Ground Fault
Protection

Standard Terminals Only➀
Adjustable Rating Plug

See Page 85 for
Optional Terminals

Adjustable Ampere Ratings
Catalog Number

Catalog Number

2-Pole
800

NDC2800T33W NDC2800T32W NDC2800T35W NDC2800T36W

400
450
500
600
700
800

8NES400T
8NES450T
8NES500T
8NES600T
8NES700T
8NES800T

Adjustable Settings are:
400, 500, 600, 800
A8NES800T1

TA700NB1
TA700NB1
TA700NB1
TA700NB1
TA700NB1
TA1000NB1

NDC3800T33W NDC3800T32W NDC3800T35W NDC3800T36W

400
450
500
600
700
800

8NES400T
8NES450T
8NES500T
8NES600T
8NES700T
8NES800T

Adjustable Settings are:
400, 500, 600, 800
A8NES800T1

TA700NB1
TA700NB1
TA700NB1
TA700NB1
TA700NB1
TA1000NB1

NDC4800T33W NDC4800T32W

8NES400T
8NES450T
8NES500T
8NES600T
8NES700T
8NES800T

Adjustable Settings are:
400, 500, 600, 800
A8NES800T1

TA700NB1
TA700NB1
TA700NB1
TA700NB1
TA700NB1
TA1000NB1

3-Pole
800

4-Pole➁
800

–

–

400
450
500
600
700
800

2-Pole
1200

NDC212T33W

NDC212T32W

NDC212T35W

NDC212T36W

600
700
800
900
1000
1200

12NES600T
12NES700T
12NES800T
12NES900T
12NES1000T
12NES1200T

Adjustable Settings are:
600, 800, 1000, 1200
A12NES1200T1

TA700NB1
TA700NB1
TA1000NB1
TA1000NB1
TA1000NB1
TA1200NB1

NDC312T33W

NDC312T32W

NDC312T35W

NDC312T36W

600
700
800
900
1000
1200

12NES600T
12NES700T
12NES800T
12NES900T
12NES1000T
12NES1200T

Adjustable Settings are:
600, 800, 1000, 1200
A12NES1200T1

TA700NB1
TA700NB1
TA1000NB1
TA1000NB1
TA1000NB1
TA1200NB1

NDC412T33W

NDC412T32W

–

–

600
700
800
900
1000
1200

12NES600T
12NES700T
12NES800T
12NES900T
12NES1000T
12NES1200T

Adjustable Settings are:
600, 800, 1000, 1200
A12NES1200T1

TA700NB1
TA700NB1
TA1000NB1
TA1000NB1
TA1000NB1
TA1200NB1

3-Pole
1200

4-Pole➁
1200

Instruction Leaflet/FRED Number 29C106

➀ Two terminals are required per pole.
➁ Neutral is in right pole.

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

80

Cutler-Hammer

Molded Case Circuit Breakers
400-1200 Amperes

March 1999

Series C N-Frame

100% Rated Type CND Electronic Circuit Breakers with Non-Interchangeable Trip Units
The NEC allows the breaker to be rated at 100% of its frame size in an assembly, provided that 90°C wire is applied at
the 75°C ampacity. Order as individual components: Breaker Frame, Rating Plug, Terminals
Maximum
Continuous
Ampere
Rating
@ 40°C

Digitrip RMS 310 Circuit Breaker Frame Only

Digitrip RMS 310 Rating Plug Only

Standard Interrupting Capacity
600 Volt Ac Rated 50 kAIC @ 480 Vac

Ampere
Rating

Standard

Options

Adjustable
Short Time
Delay with I2t
Short Delay
Ramp

Independently
Adjustable
Short Time
Pickup and
Delay

Adjustable
Short Time
Pickup with I2t
Short Delay and
Ground Fault
Protection

Fixed
Rating
Plugs

Independently
Adjustable
Short Time
Pickup and
Delay and
Ground Fault
Protection

Standard Terminals Only➀
Adjustable Rating Plug

See Page 85 for
Optional Terminals

Adjustable Ampere Ratings
Catalog Number

Catalog Number

2-Pole
800

CND2800T33W CND2800T32W CND2800T35W CND2800T36W

400
450
500
600
700
800

8NES400T
8NES450T
8NES500T
8NES600T
8NES700T
8NES800T

Adjustable Settings are:
400, 500, 600, 800
A8NES800T1

TA700NB1
TA700NB1
TA700NB1
TA700NB1
TA700NB1
TA1000NB1

CND3800T33W CND3800T32W CND3800T35W CND3800T36W

400
450
500
600
700
800

8NES400T
8NES450T
8NES500T
8NES600T
8NES700T
8NES800T

Adjustable Settings are:
400, 500, 600, 800
A8NES800T1

TA700NB1
TA700NB1
TA700NB1
TA700NB1
TA700NB1
TA1000NB1

CND4800T33W CND4800T32W

8NES400T
8NES450T
8NES500T
8NES600T
8NES700T
8NES800T

Adjustable Settings are:
400, 500, 600, 800
A8NES800T1

TA700NB1
TA700NB1
TA700NB1
TA700NB1
TA700NB1
TA1000NB1

3-Pole
800

4-Pole➁
800

–

–

400
450
500
600
700
800

2-Pole
1200

CND212T33W

CND212T32W

CND212T35W

CND212T36W

600
700
800
900
1000
1200

12NES600T
12NES700T
12NES800T
12NES900T
12NES1000T
12NES1200T

Adjustable Settings are:
600, 800, 1000, 1200
A12NES1200T1

TA700NB1
TA700NB1
TA1000NB1
TA1000NB1
TA1000NB1
TA1200NB1

CND312T33W

CND312T32W

CND312T35W

CND312T36W

600
700
800
900
1000
1200

12NES600T
12NES700T
12NES800T
12NES900T
12NES1000T
12NES1200T

Adjustable Settings are:
600, 800, 1000, 1200
A12NES1200T1

TA700NB1
TA700NB1
TA1000NB1
TA1000NB1
TA1000NB1
TA1200NB1

CND412T33W

CND412T32W

–

–

600
700
800
900
1000
1200

12NES600T
12NES700T
12NES800T
12NES900T
12NES1000T
12NES1200T

Adjustable Settings are:
600, 800, 1000, 1200
A12NES1200T1

TA700NB1
TA700NB1
TA1000NB1
TA1000NB1
TA1000NB1
TA1200NB1

3-Pole
1200

4-Pole➁
1200

Instruction Leaflet/FRED Number 29C106

➀ Two terminals are required per pole.
➁ Neutral is in right pole.

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

Cutler-Hammer

Molded Case Circuit Breakers
400-1200 Amperes

March 1999

81

Series C N-Frame

100% Rated Type CHND Electronic Circuit Breakers with Non-Interchangeable Trip Units
The NEC allows the breaker to be rated at 100% of its frame size in an assembly, provided that 90°C wire is applied at
the 75°C ampacity. Order as individual components: Breaker Frame, Rating Plug, Terminals
Maximum
Continuous
Ampere
Rating
@ 40°C

Digitrip RMS 310 Circuit Breaker Frame Only

Digitrip RMS 310 Rating Plug Only

High Interrupting Capacity
600 Volt Ac Rated 65 kAIC @ 480 Vac

Ampere
Rating

Standard

Options

Adjustable Short
Time Delay with
I2t Short Delay
Ramp

Independently
Adjustable Short
Time Pickup and
Delay

Adjustable Short
Time Pickup with
I2t Short Delay
and Ground Fault
Protection

Fixed
Rating
Plugs

Adjustable Rating Plug

Independently
Adjustable Short
Time Pickup and
Delay and Ground
Fault Protection

Standard Terminals Only➀
See Page 85 for
Optional Terminals

Adjustable Ampere Ratings
Catalog Number

Catalog Number

2-Pole
800

CHND2800T33W CHND2800T32W CHND2800T35W CHND2800T36W

400
450
500
600
700
800

8NES400T
8NES450T
8NES500T
8NES600T
8NES700T
8NES800T

Adjustable Settings are:
400, 500, 600, 800
A8NES800T1

TA700NB1
TA700NB1
TA700NB1
TA700NB1
TA700NB1
TA1000NB1

CHND3800T33W CHND3800T32W CHND3800T35W CHND3800T36W

400
450
500
600
700
800

8NES400T
8NES450T
8NES500T
8NES600T
8NES700T
8NES800T

Adjustable Settings are:
400, 500, 600, 800
A8NES800T1

TA700NB1
TA700NB1
TA700NB1
TA700NB1
TA700NB1
TA1000NB1

CHND4800T33W CHND4800T32W

8NES400T
8NES450T
8NES500T
8NES600T
8NES700T
8NES800T

Adjustable Settings are:
400, 500, 600, 800
A8NES800T1

TA700NB1
TA700NB1
TA700NB1
TA700NB1
TA700NB1
TA1000NB1

3-Pole
800

4-Pole➁
800

–

–

400
450
500
600
700
800

2-Pole
1200

CHND212T33W

CHND212T32W

CHND212T35W

CHND212T36W

600
700
800
900
1000
1200

12NES600T
12NES700T
12NES800T
12NES900T
12NES1000T
12NES1200T

Adjustable Settings are:
600, 800, 1000, 1200
A12NES1200T1

TA700NB1
TA700NB1
TA1000NB1
TA1000NB1
TA1000NB1
TA1200NB1

CHND312T33W

CHND312T32W

CHND312T35W

CHND312T36W

600
700
800
900
1000
1200

12NES600T
12NES700T
12NES800T
12NES900T
12NES1000T
12NES1200T

Adjustable Settings are:
600, 800, 1000, 1200
A12NES1200T1

TA700NB1
TA700NB1
TA1000NB1
TA1000NB1
TA1000NB1
TA1200NB1

CHND412T33W

CHND412T32W

–

–

600
700
800
900
1000
1200

12NES600T
12NES700T
12NES800T
12NES900T
12NES1000T
12NES1200T

Adjustable Settings are:
600, 800, 1000, 1200
A12NES1200T1

TA700NB1
TA700NB1
TA1000NB1
TA1000NB1
TA1000NB1
TA1200NB1

3-Pole
1200

4-Pole➁
1200

Instruction Leaflet/FRED Number 29C106

➀ Two terminals are required per pole.
➁ Neutral is in right pole.

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

82

Cutler-Hammer

Molded Case Circuit Breakers
400-1200 Amperes

March 1999

Series C N-Frame

100% Rated Type CNDC Electronic Circuit Breakers with Non-Interchangeable Trip Units
The NEC allows the breaker to be rated at 100% of its frame size in an assembly, provided that 90°C wire is applied at
the 75°C ampacity. Order as individual components: Breaker Frame, Rating Plug, Terminals
Maximum
Continuous
Ampere
Rating
@ 40°C

Digitrip RMS 310 Circuit Breaker Frame Only

Digitrip RMS 310 Rating Plug Only

Ultra High Interrupting Capacity
600 Volt Ac Rated 100 kAIC @ 480 Vac

Ampere
Rating

Standard

Options

Adjustable Short
Time Delay with
I2t Short Delay
Ramp

Independently
Adjustable Short
Time Pickup and
Delay

Adjustable Short
Time Pickup with
I2t Short Delay
and Ground Fault
Protection

Fixed
Rating
Plugs

Adjustable Rating Plug

Independently
Adjustable Short
Time Pickup and
Delay and Ground
Fault Protection

Standard Terminals Only➀
See Page 85 for
Optional Terminals

Adjustable Ampere Ratings
Catalog Number

Catalog Number

2-Pole
800

CNDC2800T33W CNDC2800T32W CNDC2800T35W CNDC2800T36W

400
450
500
600
700
800

8NES400T
8NES450T
8NES500T
8NES600T
8NES700T
8NES800T

Adjustable Settings are:
400, 500, 600, 800
A8NES800T1

TA700NB1
TA700NB1
TA700NB1
TA700NB1
TA700NB1
TA1000NB1

CNDC3800T33W CNDC3800T32W CNDC3800T35W CNDC3800T36W

400
450
500
600
700
800

8NES400T
8NES450T
8NES500T
8NES600T
8NES700T
8NES800T

Adjustable Settings are:
400, 500, 600, 800
A8NES800T1

TA700NB1
TA700NB1
TA700NB1
TA700NB1
TA700NB1
TA1000NB1

CNDC4800T33W CNDC4800T32W

8NES400T
8NES450T
8NES500T
8NES600T
8NES700T
8NES800T

Adjustable Settings are:
400, 500, 600, 800
A8NES800T1

TA700NB1
TA700NB1
TA700NB1
TA700NB1
TA700NB1
TA1000NB1

3-Pole
800

4-Pole➁
800

–

–

400
450
500
600
700
800

2-Pole
1200

CNDC212T33W

CNDC212T32W

CNDC212T35W

CNDC212T36W

600
700
800
900
1000
1200

12NES600T
12NES700T
12NES800T
12NES900T
12NES1000T
12NES1200T

Adjustable Settings are:
600, 800, 1000, 1200
A12NES1200T1

TA700NB1
TA700NB1
TA1000NB1
TA1000NB1
TA1000NB1
TA1200NB1

CNDC312T33W

CNDC312T32W

CNDC312T35W

CNDC312T36W

600
700
800
900
1000
1200

12NES600T
12NES700T
12NES800T
12NES900T
12NES1000T
12NES1200T

Adjustable Settings are:
600, 800, 1000, 1200
A12NES1200T1

TA700NB1
TA700NB1
TA1000NB1
TA1000NB1
TA1000NB1
TA1200NB1

CNDC412T33W

CNDC412T32W

–

–

600
700
800
900
1000
1200

12NES600T
12NES700T
12NES800T
12NES900T
12NES1000T
12NES1200T

Adjustable Settings are:
600, 800, 1000, 1200
A12NES1200T1

TA700NB1
TA700NB1
TA1000NB1
TA1000NB1
TA1000NB1
TA1200NB1

3-Pole
1200

4-Pole➁
1200

Instruction Leaflet/FRED Number 29C106

➀ Two terminals are required per pole.
➁ Neutral is in right pole.

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

Cutler-Hammer

Molded Case Circuit Breakers
400-1200 Amperes

March 1999

83

Series C N-Frame

Digitrip OPTIM➀ Electronic Circuit Breakers with Interchangeable Rating Plugs
Order as individual components: Breaker Frame (which includes Trip Unit), Rating Plug, Terminals.
Maximum
Continuous
Ampere
Rating
@ 40°C

Circuit Breaker Frame Only

Digitrip OPTIM Rating
Plug Only

L – Adjustable Long Delay Pickup (Ir) with Adjustable Long Delay Time (I2t or I4t Response)➁
S – Adjustable Short Delay Pickup with Adjustable Short Delay Time (I 2t or Flat Response)
I – Adjustable Instantaneous Pickup
G – Adjustable Ground Fault Pickup with Adjustable Ground Fault Time Delay (I 2t or Flat Response)
A – Adjustable Ground Fault Alarm with Adjustable Ground Fault Time Delay (I 2t or Flat Response)

Ampere
Rating

OPTIM 550

OPTIM 550

OPTIM 550

OPTIM 750

OPTIM 750

OPTIM 1050

OPTIM 1050

LSI

LSIG

LSIA

LSIG

LSIA

LSIG

LSIA

Fixed
Rating
Plug

Catalog Number

3-Pole Standard Interrupting Capacity 600 Volt Ac Rated 50 kAIC @ 480 Vac
800

ND3800T52W

ND3800T56W

ND3800T57W

ND3800T76W

ND3800T77W

ND3800T106W

ND3800T107W

400
450
500
550
600
700
800

ORPN80A400
ORPN80A450
ORPN80A500
ORPN80A550
ORPN80A600
ORPN80A700
ORPN80A800

1200

ND312T52W

ND312T56W

ND312T57W

ND312T76W

ND312T77W

ND312T106W

ND312T107W

600
700
800
1000
1200

ORPN80A600
ORPN80A700
ORPN80A800
ORPN80A100
ORPN80A120

3-Pole High Interrupting Capacity 600 Volt Ac Rated 65 kAIC @ 480 Vac
800

HND3800T52W

HND3800T56W

HND3800T57W

HND3800T76W

HND3800T77W

HND3800T106W

HND3800T107W

400
450
500
550
600
700
800

ORPN80A400
ORPN80A450
ORPN80A500
ORPN80A550
ORPN80A600
ORPN80A700
ORPN80A800

1200

HND312T52W

HND312T56W

HND312T57W

HND312T76W

HND312T77W

HND312T106W

HND312T107W

600
700
800
1000
1200

ORPN80A600
ORPN80A700
ORPN80A800
ORPN80A100
ORPN80A120

3-Pole Ultra High Interrupting Capacity 600 Volt Ac Rated 100 kAIC @ 480 Vac
800

NDC3800T52W

NDC3800T56W

NDC3800T57W

NDC3800T76W

NDC3800T77W

NDC3800T106W

NDC3800T107W

400
450
500
550
600
700
800

ORPN80A400
ORPN80A450
ORPN80A500
ORPN80A550
ORPN80A600
ORPN80A700
ORPN80A800

1200

NDC312T52W

NDC312T56W

NDC312T57W

NDC312T76W

NDC312T77W

NDC312T106W

NDC312T107W

600
700
800
1000
1200

ORPN80A600
ORPN80A700
ORPN80A800
ORPN80A100
ORPN80A120

Instruction Leaflet/FRED Number 29C106 for Breaker; 29C891 for OPTIM Trip

➀ 1 Form C auxiliary switch and 1 Form C bell
(trip) alarm switch supplied with breaker as
standard on models 750 and 1050.
➁ Long delay I4t response selection limits short
delay time to flat response.

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

84

Cutler-Hammer

Molded Case Circuit Breakers
400-1200 Amperes

March 1999

Series C N-Frame

100% Rated Digitrip OPTIM➀ Circuit Breakers with Interchangeable Rating Plugs
Order as individual components: Breaker Frame (which includes Trip Unit), Rating Plug, Terminals.
Maximum
Continuous
Ampere
Rating
@ 40°C

Circuit Breaker Frame Only

Digitrip OPTIM Rating
Plug Only

L – Adjustable Long Delay Pickup (Ir) with Adjustable Long Delay Time (I2t or I4t Response)➁
S – Adjustable Short Delay Pickup with Adjustable Short Delay Time (I 2t or Flat Response)
I – Adjustable Instantaneous Pickup
G – Adjustable Ground Fault Pickup with Adjustable Ground Fault Time Delay (I 2t or Flat Response)
A – Adjustable Ground Fault Alarm with Adjustable Ground Fault Time Delay (I 2t or Flat Response)

Ampere
Rating

OPTIM 550

OPTIM 550

OPTIM 550

OPTIM 750

OPTIM 750

OPTIM 1050

OPTIM 1050

LSI

LSIG

LSIA

LSIG

LSIA

LSIG

LSIA

Fixed
Rating
Plug

Catalog Number

3-Pole Standard Interrupting Capacity 600 Volt Ac Rated 50 kAIC @ 480 Vac
800

CND3800T52W

CND3800T56W

CND3800T57W

CND3800T76W

CND3800T77W

CND3800T106W

CND3800T107W

400
450
500
550
600
700
800

ORPN80A400
ORPN80A450
ORPN80A500
ORPN80A550
ORPN80A600
ORPN80A700
ORPN80A800

1200

CND312T52W

CND312T56W

CND312T57W

CND312T76W

CND312T77W

CND312T106W

CND312T107W

600
700
800
1000
1200

ORPN80A600
ORPN80A700
ORPN80A800
ORPN80A100
ORPN80A120

400
450
500
550
600
700
800

ORPN80A400
ORPN80A450
ORPN80A500
ORPN80A550
ORPN80A600
ORPN80A700
ORPN80A800

CNHD312T107W

600
700
800
1000
1200

ORPN80A600
ORPN80A700
ORPN80A800
ORPN80A100
ORPN80A120

400
450
500
550
600
700
800

ORPN80A400
ORPN80A450
ORPN80A500
ORPN80A550
ORPN80A600
ORPN80A700
ORPN80A800

600
700
800
1000
1200

ORPN80A600
ORPN80A700
ORPN80A800
ORPN80A100
ORPN80A120

3-Pole High Interrupting Capacity 600 Volt Ac Rated 65 kAIC @ 480 Vac
800

CHND3800T52W

CHND3800T56W

CHND3800T57W

CHND3800T76W CHND3800T77W CHND3800T106W CHND3800T107W

1200

CHND312T52W

CHND312T56W

CHND312T57W

CHND312T76W

CHND312T77W

CHND312T106W

3-Pole Ultra High Interrupting Capacity 600 Volt Ac Rated 100 kAIC @ 480 Vac
800

CNDC3800T52W

CNDC3800T56W

CNDC3800T57W

CNDC3800T76W

CNDC3800T77W CNDC3800T106W CNDC3800T107W

1200

CNDC312T52W

CNDC312T56W

CNDC312T57W

CNDC312T76W

CNDC312T77W

CNDC312T106W

CNDC312T107W

Instruction Leaflet/FRED Number 29C106 for Breaker; 29C891 for OPTIM Trip

➀ 1 Form C auxiliary switch and 1 Form C bell
(trip) alarm switch supplied with breaker as
standard on models 750 and 1050.
➁ Long delay I4t response selection limits short
delay time to flat response.

PG.74A.01.T.E

Cutler-Hammer

Molded Case Circuit Breakers
400-1200 Amperes

March 1999

85

Series C N-Frame

Type ND Molded Case Switches
Continuous
Ampere
Rating
@ 40°C

Catalog Number
2-Pole

3-Pole

4-Pole➀

Complete with Standard Line and Load Terminals (shipped separately)
Type ND – HIgh Instantaneous (K)

800

–

ND3800WK

ND4800WK

Type ND – HIgh Instantaneous (K)

1200

–

ND312WK

ND412WK

Note: Molded case switch may trip above 14,000 amperes.
For UL listed, series tested molded case switch application data, refer to Cutler-Hammer.
Instruction Leaflet/FRED Number 29C106

Line and Load Terminals
Ordering Information
N-frame circuit breakers use Cu/AI terminals as standard. When optional copper or Cu/AI terminals are required, order
by catalog number. Specify if factory installation is required.
Line and Load Terminals
Maximum Breaker Amperes

Terminal Body Material

Wire Type

AWG Wire Range/No. Conductors

Metric Wire Range mm2

Catalog Number

Standard Cu/AI Pressure Terminals
Aluminum
Aluminum
Aluminum
Aluminum

700
1000
1200
1200

Cu/AI
Cu/AI
Cu/AI
Cu/AI

(2) 1-500 kcmil
(3) 3/0-400 kcmil
(4) 4/0-500 kcmil
(3) 500-750 kcmil

50-300
95-185
120-300
300-400

Cu
Cu
Cu

(2) 2/0-500 kcmil
(3) 3/0-500 kcmil
(4) 3/0-400 kcmil

70-300
95-300
95-185

TA700NB1
TA1000NB1➁
TA1200NB1➁
TA1201NB1➂

Optional Copper and Cu/AI Pressure Type Terminals
700
1000
1200

Copper
Copper
Copper

TA700NB1

TA1000NB1

TA1200NB1

TA1201NB1

T700NB1

T1000NB1

➀ Neutral is in right pole.
➁ Terminal rating is A19 Cu.
➂ Terminal rating is A17 Cu.

PG.74A.01.T.E

T700NB1
T1000NB1
T1200NB3

86

Cutler-Hammer

Molded Case Circuit Breakers
400-1200 Amperes

March 1999

Series C N-Frame

Catalog Numbering System
This information is presented only as an aid to understanding catalog numbers. It is not to be used to build catalog
numbers for circuit breakers or trip units.
Circuit Breaker/Frame Catalog Number
ND

3

12

T3

2

W

Circuit Breaker/
Frame Type

Number
of Poles

Circuit Breaker/
Frame Ampere
Rating

Trip Model

Trip Type

Suffix

ND
HND
NDC
CND
CHND
CNDC

2: 2 Poles
3: 3 Poles
4: 4 Poles

8: 800 Amperes
12: 1200 Amperes

T3
T5
T7
T10

2
3
5
6
7

E: 100% R.P. protected (4-Pole)
EH: 50% R.P. protected (4-Pole)
K: High Magnetic Molded
Case Switch
W: Without Terminals
X: Load Only Terminals
Y: Line Only Terminals

– Model 310
– Model 550
– Model 750
– Model 1050

– LSI
– LS
– LSG
– LSIG
– LSIA

Dimensions/Weights
Dimensions, Inches (mm)
Number of Poles

Width

Height

Depth

2, 3

8.25
(210)

16
(407)

5.5
(140)

4

11.125
(283)

16
(407)

5.5
(140)

Approximate Shipping Weight, Lbs. (kg)
Breaker Type

Complete Breaker
Number of Poles
2

ND, HND, NDC

3

37
(16.783)

4

45
(20.412)

58
(26.308)

PG.74A.01.T.E

Cutler-Hammer

Molded Case Circuit Breakers
400-1200 Amperes

March 1999

87

Series C N-Frame

Allowable Accessory Combinations
Different combinations of accessories can be supplied, depending on the types of accessories and the number of poles
in the circuit breaker.
Reference
Page

3-Pole
Left

4-Pole
Center

Right

Left

Center

Right

Neu.

Internal Accessories (Only One Internal Accessory Per Pole)➀
Alarm Lockout (Make/Break)

141

Alarm Lockout (2Make/2Break)

141

Auxiliary Switch (1A, 1B)

144

Auxiliary Switch (2A, 2B)

144

Auxiliary Switch (3A, 3B)

144

Auxiliary Switch (1A 1B) and Alarm Switch Combination

146

Auxiliary Switch (2A 2B) and Alarm Switch Combination

146

Shunt Trip – Standard

150

Shunt Trip – Low Energy

152

Undervoltage Release Mechanism

158

Cutler-Hammer PowerNet Communications Kit (OPTIM 550)

160

■
■
■
■
■
■
■
■
■
■

■
■
■
■
■
■
■

■
■
■
■
■
■
■
■
■
■

■
■
■
■
■
■
■

■

External Accessories
Base Mounting Hardware

163

Interphase Barriers

166

Non-Padlockable Handle Block

168

Padlockable Handle Lock Hasp

169

Key Interlock Kit

170

Sliding Bar Interlock – Requires Two Breakers

171

Walking Beam Interlock – Requires Two Breakers

171

Electrical (Motor) Operator

173

Plug-in Adapters

174

Rear Connecting Studs

176

Panelboard Connecting Straps

177

Handle Mechanisms

178

Handle Extension

182

Solid-State (Electronic) Portable Test Kit

184

●
●
■
❏
❏

●
●
■
❏
❏

❏
❏

❏
❏

●
●
●
●
●
●
●
●
●

●
●
●
●
●
●
●
●

●
●
●
●

●
●
●
●

OPTIM System Components 3-Poles
Ground Fault Alarm Unit

184

Potential Transformer Module

184

Breaker Interface Module (BIM)

185

Digitrip OPTIMizer

185

Auxiliary Power Module

185

Cutler-Hammer PowerNet Software

185

Modifications (Refer to Cutler-Hammer)
Special Calibration

186

Moisture Fungus Treatment

186

Freeze-Tested Circuit Breakers

186

Marine Application

186

■ Applicable in indicated pole position

❏ May be mounted on left or right pole –
not both

➀ OPTIM 750 and 1050 are factory sealed
and do not have the right pole available for
accessories.

PG.74A.01.T.E

● Accessory available/Modification available

88

Molded Case Circuit Breakers

Cutler-Hammer
March 1999

PG.74A.01.T.E

Cutler-Hammer

Molded Case Circuit Breakers
800-2500 Amperes

March 1999

89

Series C R-Frame

Typical Series C R-Frame Circuit Breaker
■

■

R-frame circuit breakers are available as frame (which includes trip
unit), rating plug and terminals.
All R-frame circuit breakers are
suitable for reverse feed use.

Interrupting Capacity Ratings
UL489/CSA Interrupting Capacity Ratings ➀
Circuit
Breaker
Type

Number of
Poles

Interrupting Capacity (Symmetrical Amperes) (kA)
Volts Ac (50/60 Hz)
240

277

480

Circuit
Breaker
Type

600

Page Numbers
Trip Unit Types➁
310

510

610

810

910

OPTIM

RD

3, 4

125

–

65

50

RD

91

94

96

98

100

102

CRD ➂

3, 4

125

–

65

50

CRD

93

95

97

99

101

103

RDC

3, 4

200

–

100

65

RDC

92

94

96

98

100

102

CRDC ➂

3, 4

200

–

100

65

CRDC

93

95

97

99

101

103

Interrupting Capacity (Symmetrical Amperes) (kA)

Circuit
Breaker
Type

IEC 947-2 Interrupting Capacity Ratings ➀
Circuit
Breaker
Type

Number of
Poles

Volts Ac (50/60 Hz)
240

RD
ICU
ICS

3, 4

RDC
ICU
ICS

3, 4

415

Trip Unit Types➁
310

135
100

70
50

25
13

200
100

100
50

35
18

➀ Utilization Category A circuit breakers.
➁ See page 90 for Trip Unit Selection Guide
➂ 100% Rated breakers.

PG.74A.01.T.E

690

Page Numbers

510

610

810

910

OPTIM

RD

91

94

96

98

100

102

RDC

92

94

96

98

100

102

Cutler-Hammer

Molded Case Circuit Breakers
125-600 Amperes

90

March 1999

Series C R-Frame

R-Frame Digitrip Selection Guide
Trip Unit Type

Digitrip
RMS 310

Digitrip
RMS 510

RMS Sensing
Breaker Type
Frame
Ampere Range
Interrupting Rating @ 480V
Protection
Ordering Options

Fixed Rated Plug (In)
Overtemperature Trip
Long Delay Protection (L)
Adjustable Rating Plug (In)
Long Delay Pickup
Long Delay Time I2T
Long Delay Time I4T
Long Delay Thermal Memory
High Load Alarm
Short Delay Protection (S)
Short Delay Pickup
Short Delay Time I2T
Short Delay Time Flat
Short Delay Time Zone
Selective Interlocking
Instantaneous Protection (I)
Instantaneous Pick Up
Discriminator
Instantaneous Override
Ground Fault Protection (G)
Ground Fault Alarm➄
Ground Fault Pick Up➄
Ground Fault Delay I2T
Ground Fault Delay Flat
Ground Fault Zone
Selective Interlocking
Ground Fault Thermal Memory

Digitrip
RMS 610

Digitrip
OPTIM 750

Digitrip
RMS 810

Digitrip
RMS 910

Digitrip
OPTIM 1050

Yes

Yes

Yes

Yes

Yes

Yes

Yes

R
800A-2500A
65, 100 (kA)

R
800A-2500A
65, 100 (kA)

R
800A-2500A
65, 100 (kA)

R
800A-2500A
65, 100 (kA)

R
800A-2500A
65, 100 (kA)

R
800A-2500A
65, 100 (kA)

R
800A-2500A
65, 100 (kA)

LI, LS, LSI, LIG
LSG, LSIG

LSI(A), LSIG

Yes
Yes

LI, LS, LSI,
LIG, LSG,
LSIG
Yes
Yes

LSI(A), LISG

Yes
Yes

LI, LS, LSI,
LIG, LSG,
LSIG
Yes
Yes

LS, LSG

LSI, LSIG

Yes
Yes

Yes
Yes

LI, LS, LSI,
LIG, LSG,
LSIG
Yes
Yes

Yes
0.5-1.0 (In)➀
12 Seconds
No
Yes
No

Yes
0.5-1.0 (In)➀
12 Seconds
No
Yes
No

No
0.5-1.0 x (In)
2-24 Seconds
No
Yes
No

No
0.5-1.0 x (In)
2-24 Seconds
No
Yes
0.85 x Ir

No
0.4-1.0 x (In)
2-24 Seconds
1-5 Seconds
Yes
0.5-1.0 x Ir

No
0.5-1.0 x (In)
2-24 Seconds
No
Yes
0.85 x Ir

No
0.5-1.0 x (In)
2-24 Seconds
No
Yes
0.85 x Ir

No
0.4-1.0 x (In)
2-24 Seconds
1-5 Seconds
Yes
0.5-1.0 x Ir

200-800% x (In)➁

200-800% x (In)➁

200-600%
S1&S2 x (Ir)
100-500 ms
100-500 ms
Yes

200-600%
S1&S2 x (Ir)
100-500 ms
100-500 ms
Yes

150-800% x (Ir)➁➂

No
Inst-300 ms
No

200-600%
S1&S2 x (Ir)
100-500 ms
100-500 ms
Yes

150-800% x (Ir)➁➂

100 ms
No
No

200-600%
S1&S2 x (Ir)
100-500 ms
100-500 ms
Yes

No

200-800% x (In)

Yes
Yes

200-600%
M1&M2 x (In)
Yes➃
Yes

200-600%
M1&M2 x (In)
Yes➃
Yes

200-800% x (In)➂

No
Yes

200-600%
M1&M2 x (In)
Yes➃
Yes

200-800% x (In)➂

No
Yes

200-600%
M1&M2 x (In)
Yes➃
Yes

No
Varies by Frame
No
Inst-500 ms
No

No
Varies by Frame
No
Inst-500 ms
No

No
25-100% x (Is)
100-500 ms
100-500 ms
Yes

No
25-100% x (Is)
100-500 ms
100-500 ms
Yes

25-100% x (In)
25-100% x (In)
100-500 ms
100-500 ms
Yes

No
25-100% x (Is)
100-500 ms
100-500 ms
Yes

No
25-100% x (Is)
100-500 ms
100-500 ms
Yes

25-100% x (In)
25-100% x (In)
100-500 ms
100-500 ms
Yes

100-500 ms
100-500 ms
Yes

Yes
Yes

100-500 ms
100-500 ms
Yes

Yes
Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

System Diagnostics
Status LEDs
Cause of Trip LEDs
Magnitude of Trip Information
Remote Signal Contacts

Yes
No
No
Yes

Yes
No
No
Yes

Yes
Yes
No
No

Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes

System Monitoring
Digital Display
Current
Voltage
Power and Energy
Power Quality-Harmonics
Power Factor

No
No
No
No
No
No

No
No
No
No
No
No

No
No
No
No
No
No

Yes
Yes
No
No
No
No

Yes➅
Yes
No
No
No
No

Yes
Yes
No
Yes
No
Yes (Over
Cutler-Hammer PowerNet Only)

Yes
Yes
Yes
Yes
Yes
Yes

Yes➅
Yes
No
Yes
Yes
Yes

Communications
Cutler-Hammer PowerNet

No

No

No

No

Yes

Yes

Yes

Yes

Integral

Integral

OPTIMizer,
BIM, Cutler-Hammer PowerNet

Integral

Integral

OPTIMizer,
BIM, Cutler-Hammer PowerNet

Testing
Testing Method

➀
➁
➂
➃

Test Set

Adjust by rating plug.
Except 2500 ampere frame is 200-600%.
Varies by frame.
LS/LSG only.

➄ Not to exceed 1200 amperes.
➅ By OPTIMizer/BIM.
BIM = Breaker Interface Module
(A) = GF Alarm

Is = Sensor Rating
In = Rating Plug
Ir = Long Delay Pickup Setting x In

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

Cutler-Hammer

Molded Case Circuit Breakers
800-2500 Amperes

March 1999

91

Series C R-Frame

Digitrip RMS 310 Electronic Circuit Breakers with Interchangeable Rating Plugs
Order as individual components: Breaker Frame (which includes Trip Unit) and Rating Plug.
Maximum
Continuous
Ampere
Rating
@ 40°C

Circuit Breaker Frame Only

Digitrip RMS 310 Rating Plug Only

L – Adjustable Long Delay Pickup (By Adjustable Rating Plug)
S – Adjustable Short Delay Pickup with Fixed Short Delay Time
(I2t Response) or Adjustable Short Delay Time (Flat Response)
I – Adjustable Instantaneous Pickup by Setting Short Delay Time to Instantaneous
G – Adjustable Ground Fault Pickup with Adjustable Ground Fault Time (Flat Response)

Ampere
Rating

LS

LSG➂

LSI

Fixed
Rating
Plug

Adjustable Rating Plug
Adjustable Ampere Ratings
Catalog Number

LSIG➂

Catalog Number

3-Pole Standard Interrupting Capacity 600 Volt Ac Rated 65 kAIC @ 480 Vac
1600➀

RD316T33W

RD316T32W

RD316T35W

RD316T36W

800
1000
1200
1250
1400
1500
1600

16RES08T
16RES10T
16RES12T
16RES125T
16RES14T
16RES15T
16RES16T

Adjustable Settings are:
800, 1000, 1200, 1600
A16RES16T1

2000

RD320T33W

RD320T32W

RD320T35W

RD320T36W

1000
1200
1250
1400
1600
2000

20RES10T
20RES12T
20RES125T
20RES14T
20RES16T
20RES20T

Adjustable Settings are:
1000, 1200, 1600, 2000
A20RES20T1

2500

RD325T33W

RD325T32W

RD325T35W

RD325T36W

1200
1250
1600
2000
2500

25RES12T
25RES125T
25RES16T
25RES20T
25RES25T

Adjustable Settings are:
1200, 1600, 2000, 2500
A25RES25T1

4-Pole➁ Standard Interrupting Capacity 600 Volt Ac Rated 65 kAIC @ 480 Vac
1600➀

RD416T33W

RD416T32W

–

–

800
1000
1200
1250
1400
1500
1600

16RES08T
16RES10T
16RES12T
16RES125T
16RES14T
16RES15T
16RES16T

Adjustable Settings are:
800, 1000, 1200, 1600
A16RES16T1

2000

RD420T33W

RD420T32W

–

–

1000
1200
1250
1400
1600
2000

20RES10T
20RES12T
20RES125T
20RES14T
20RES16T
20RES20T

Adjustable Settings are:
1000, 1200, 1600, 2000
A20RES20T1

2500

RD425T33W

RD425T32W

–

–

1200
1250
1600
2000
2500

25RES12T
25RES125T
25RES16T
25RES20T
25RES25T

Adjustable Settings are:
1200, 1600, 2000, 2500
A25RES25T1

Instruction Leaflet/FRED Number 29C107 for Breaker; Number 29C883 for Digitrip 310 Trip Unit

➀ For SCR application use 2000 ampere frame.
➁ Unprotected right pole neutral. Add “P” to
catalog number for 100% protected right
pole neutral, i.e., “RD416T33PW”.
➂ Add suffix “R” to breaker catalog number for
ground fault remote indication
compatibility.

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

92

Cutler-Hammer

Molded Case Circuit Breakers
800-2500 Amperes

March 1999

Series C L-Frame

Digitrip RMS 310 Electronic Circuit Breakers with Interchangeable Rating Plugs
Order as individual components: Breaker Frame (which includes Trip Unit) and Rating Plug.
Maximum
Continuous
Ampere
Rating
@ 40°C

Circuit Breaker Frame Only

Digitrip RMS 310 Rating Plug Only

L – Adjustable Long Delay Pickup (By Adjustable Rating Plug)
S – Adjustable Short Delay Pickup with Fixed Short Delay Time
(I2t Response) or Adjustable Short Delay Time (Flat Response)
I – Adjustable Instantaneous Pickup by Setting Short Delay Time to Instantaneous
G – Adjustable Ground Fault Pickup with Adjustable Ground Fault Time (Flat Response)

Ampere
Rating

LS

LSG➂

LSI

Fixed
Rating
Plug

Adjustable Rating Plug
Adjustable Ampere Ratings
Catalog Number

LSIG➂

Catalog Number

3-Pole High Interrupting Capacity 600 Volt Ac Rated 100 kAIC @ 480 Vac
1600➀

RDC316T33W

RDC316T32W

RDC316T35W

RDC316T36W

800
1000
1200
1250
1400
1500
1600

16RES08T
16RES10T
16RES12T
16RES125T
16RES14T
16RES15T
16RES16T

Adjustable Settings are:
800, 1000, 1200, 1600
A16RES16T1

2000

RDC320T33W

RDC320T32W

RDC320T35W

RDC320T36W

1000
1200
1250
1400
1600
2000

20RES10T
20RES12T
20RES125T
20RES14T
20RES16T
20RES20T

Adjustable Settings are:
1000, 1200, 1600, 2000
A20RES20T1

2500

RDC325T33W

RDC325T32W

RDC325T35W

RDC325T36W

1200
1250
1600
2000
2500

25RES12T
25RES125T
25RES16T
25RES20T
25RES25T

Adjustable Settings are:
1200, 1600, 2000, 2500
A25RES25T1

4-Pole➁ High Interrupting Capacity 600 Volt Ac Rated 100 kAIC @ 480 Vac
1600➀

RDC416T33W

RDC416T32W

–

–

800
1000
1200
1250
1400
1500
1600

16RES08T
16RES10T
16RES12T
16RES125T
16RES14T
16RES15T
16RES16T

Adjustable Settings are:
800, 1000, 1200, 1600
A16RES16T1

2000

RDC420T33W

RDC420T32W

–

–

1000
1200
1250
1400
1600
2000

20RES10T
20RES12T
20RES125T
20RES14T
20RES16T
20RES20T

Adjustable Settings are:
1000, 1200, 1600, 2000
A20RES20T1

2500

RDC425T33W

RDC425T32W

–

–

1200
1250
1600
2000
2500

25RES12T
25RES125T
25RES16T
25RES20T
25RES25T

Adjustable Settings are:
1200, 1600, 2000, 2500
A25RES25T1

Instruction Leaflet/FRED Number 29C107 for Breaker; Number 29C883 for Digitrip 310 Trip Unit

➀ For SCR application use 2000 ampere frame.
➁ Unprotected right pole neutral. Add “P” to
catalog number for 100% protected right
pole neutral, i.e., “RDC416T33PW”.
➂ Add suffix “R” to breaker catalog number for
ground fault remote indication
compatibility.

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

Cutler-Hammer

Molded Case Circuit Breakers
800-2500 Amperes

March 1999

93

Series C R-Frame

100% Rated Digitrip RMS 310 Electronic Circuit Breakers➀
The NEC allows the breaker to be rated at 100% of its frame size in an assembly, provided that 90°C wire is applied at
75°C ampacity. Order as individual components: Breaker Frame (which includes Trip Unit) and Rating Plug.
Maximum
Continuous
Ampere
Rating
@ 40°C

Circuit Breaker Frame Only

Digitrip RMS 310 Rating Plug Only

L – Adjustable Long Delay Pickup (By Adjustable Rating Plug)
S – Adjustable Short Delay Pickup with Fixed Short Delay Time
(I2t Response) or Adjustable Short Delay Time (Flat Response)
I – Adjustable Instantaneous Pickup by Setting Short Delay Time to Instantaneous
G – Adjustable Ground Fault Pickup with Adjustable Ground Fault Time (Flat Response)

Ampere
Rating

LS

LSG➂

LSI

Fixed
Rating
Plug

Adjustable Rating Plug
Adjustable Ampere Ratings
Catalog Number

LSIG➂

Catalog Number

3-Pole Standard Interrupting Capacity 600 Volt Ac Rated 65 kAIC @ 480 Vac
1600➁

CRD316T33W

CRD316T32W

CRD316T35W

CRD316T36W

800
1000
1200
1250
1400
1500
1600

16RES08T
16RES10T
16RES12T
16RES125T
16RES14T
16RES15T
16RES16T

Adjustable Settings are:
800, 1000, 1200, 1600
A16RES16T1

2000

CRD320T33W

CRD320T32W

CRD320T35W

CRD320T36W

1000
1200
1250
1400
1600
2000

20RES10T
20RES12T
20RES125T
20RES14T
20RES16T
20RES20T

Adjustable Settings are:
1000, 1200, 1600, 2000
A20RES20T1

3-Pole High Interrupting Capacity 600 Volt Ac Rated 100 kAIC @ 480 Vac
1600➀➁

CRDC316T33W

CRDC316T32W

CRDC316T35W

CRDC316T36W

800
1000
1200
1250
1400
1500
1600

16RES08T
16RES10T
16RES12T
16RES125T
16RES14T
16RES15T
16RES16T

Adjustable Settings are:
800, 1000, 1200, 1600
A16RES16T1

2000

CRDC320T33W

CRDC320T32W

CRDC320T35W

CRDC320T36W

1000
1200
1250
1400
1600
2000

20RES10T
20RES12T
20RES125T
20RES14T
20RES16T
20RES20T

Adjustable Settings are:
1000, 1200, 1600, 2000
A20RES20T1

Instruction Leaflet/FRED Number 29C107 for Breaker; Number 29C883 for Digitrip 310 Trip Unit

➀ Includes B2016RDL rear connections.
Refer to TD.29.02.T.E for dimensions.
➁ For SCR application use 2000 ampere frame.
➂ Add suffix “R” to breaker catalog number for
ground fault remote indication
compatibility.

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

94

Cutler-Hammer

Molded Case Circuit Breaker
800-2500 Amperes

March 1999

Series C R-Frame

Digitrip RMS 510 Electronic Circuit Breakers with Interchangeable Rating Plugs
Order as individual components: Breaker Frame (which includes Trip Unit) and Rating Plug.
Maximum
Continuous
Ampere
Rating
@ 40°C

Circuit Breaker Frame Only

Digitrip Rating Plug Only

L
S
I
G

Fixed Rating Plug

– Adjustable Long Delay Pickup (Ir) with Adjustable Long Delay Time
– Adjustable Short Delay Pickup with Adjustable Short Delay Time (I 2t or Flat Response)
– Adjustable Instantaneous Pickup
– Adjustable Ground Fault Pickup with Adjustable Ground Fault Time Delay (I 2t or Flat Response)

LI

LS

LSI

LIG

LSG

Rated
Current (In)

Catalog
Number

LSIG

Catalog Number

3-Pole Standard Interrupting Capacity 600 Volt Ac Rated 65 kAIC @ 480 Vac
1600

RD316T51W

RD316T53W

RD316T52W

RD316T54W

RD316T55W

RD316T56W

800
1000
1200
1600

RP6R16A080
RP6R16A100
RP6R16A120
RP6R16A160

2000

RD320T51W

RD320T53W

RD320T52W

RD320T54W

RD320T55W

RD320T56W

1000
1200
1600
2000

RP6R20A100
RP6R20A120
RP6R20A160
RP6R20A200

2500

RD325T51W

RD325T53W

RD325T52W

RD325T54W

RD325T55W

RD325T56W

1600
2000
2500

RP6R25A160
RP6R25A200
RP6R25A250

3-Pole High Interrupting Capacity 600 Volt Ac Rated 100 kAIC @ 480 Vac
1600

RDC316T51W

RDC316T53W

RDC316T52W

RDC316T54W

RDC316T55W

RDC316T56W

800
1000
1200
1600

RP6R16A080
RP6R16A100
RP6R16A120
RP6R16A160

2000

RDC320T51W

RDC320T53W

RDC320T52W

RDC320T54W

RDC320T55W

RDC320T56W

1000
1200
1600
2000

RP6R20A100
RP6R20A120
RP6R20A160
RP6R20A200

2500

RDC325T51W

RDC325T53W

RDC325T52W

RDC325T54W

RDC325T55W

RDC325T56W

1600
2000
2500

RP6R25A160
RP6R25A200
RP6R25A250

Instruction Leaflet/FRED Number 29C107 for Breaker; Number 29C885 for Digitrip 510 Trip Unit

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

Cutler-Hammer

Molded Case Circuit Breakers
800-2500 Amperes

March 1999

95

Series C R-Frame

100% Rated Digitrip RMS 510 Circuit Breakers
The NEC allows the breaker to be rated at 100% of its frame size in an assembly, provided that 90°C wire is applied at
75°C ampacity. Order as individual components: Breaker Frame (which includes Trip Unit) and Rating Plug.
Maximum
Continuous
Ampere
Rating
@ 40°C

Circuit Breaker Frame Only

Digitrip Rating Plug Only

L
S
I
G

Fixed Rating Plug

– Adjustable Long Delay Pickup (Ir) with Adjustable Long Delay Time
– Adjustable Short Delay Pickup with Adjustable Short Delay Time (I 2t or Flat Response)
– Adjustable Instantaneous Pickup
– Adjustable Ground Fault Pickup with Adjustable Ground Fault Time Delay (I 2t or Flat Response)

LI

LS

LSI

LIG

LSG

Rated
Current (In)

Catalog
Number

LSIG

Catalog Number

3-Pole Standard Interrupting Capacity 600 Volt Ac Rated 65 kAIC @ 480 Vac
1600

CRD316T51W

CRD316T53W

CRD316T52W

CRD316T54W

CRD316T55W

CRD316T56W

800
1000
1200
1600

RP6R16A080
RP6R16A100
RP6R16A120
RP6R16A160

2000

CRD320T51W

CRD320T53W

CRD320T52W

CRD320T54W

CRD320T55W

CRD320T56W

1000
1200
1600
2000

RP6R20A100
RP6R20A120
RP6R20A160
RP6R20A200

3-Pole High Interrupting Capacity 600 Volt Ac Rated 100 kAIC @ 480 Vac
1600

CRDC316T51W

CRDC316T53W

CRDC316T52W

CRDC316T54W

CRDC316T55W

CRDC316T56W

800
1000
1200
1600

RP6R16A080
RP6R16A100
RP6R16A120
RP6R16A160

2000

CRDC320T51W

CRDC320T53W

CRDC320T52W

CRDC320T54W

CRDC320T55W

CRDC320T56W

1000
1200
1600
2000

RP6R20A100
RP6R20A120
RP6R20A160
RP6R20A200

Instruction Leaflet/FRED Number 29C107 for Breaker; Number 29885 for Digitrip 510 Trip Unit

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

96

Cutler-Hammer

Molded Case Circuit Breakers
800-2500 Amperes

March 1999

Series C R-Frame

Digitrip RMS 610 Electronic Circuit Breakers with Interchangeable Rating Plugs
Order as individual components: Breaker Frame (which includes Trip Unit) and Rating Plug.
Maximum
Continuous
Ampere
Rating
@ 40°C

Circuit Breaker Frame Only

Digitrip Rating Plug Only

L
S
I
G

Fixed Rating Plug

– Adjustable Long Delay Pickup (Ir) with Adjustable Long Delay Time
– Adjustable Short Delay Pickup with Adjustable Short Delay Time (I 2t or Flat Response)
– Adjustable Instantaneous Pickup
– Adjustable Ground Fault Pickup with Adjustable Ground Fault Time Delay (I 2t or Flat Response)

LI

LS

LSI

LIG

LSG

Rated
Current (In)

Catalog
Number

LSIG

Catalog Number

3-Pole Standard Interrupting Capacity 600 Volt Ac Rated 65 kAIC @ 480 Vac
1600

RD316T61W

RD316T63W

RD316T62W

RD316T64W

RD316T65W

RD316T66W

800
1000
1200
1600

RP6R16A080
RP6R16A100
RP6R16A120
RP6R16A160

2000

RD320T61W

RD320T63W

RD320T62W

RD320T64W

RD320T65W

RD320T66W

1000
1200
1600
2000

RP6R20A100
RP6R20A120
RP6R20A160
RP6R20A200

2500

RD325T61W

RD325T63W

RD325T62W

RD325T64W

RD325T65W

RD325T66W

1600
2000
2500

RP6R25A160
RP6R25A200
RP6R25A250

3-Pole High Interrupting Capacity 600 Volt Ac Rated 100 kAIC @ 480 Vac
1600

RDC316T61W

RDC316T63W

RDC316T62W

RDC316T64W

RDC316T65W

RDC316T66W

800
1000
1200
1600

RP6R16A080
RP6R16A100
RP6R16A120
RP6R16A160

2000

RDC320T61W

RDC320T63W

RDC320T62W

RDC320T64W

RDC320T65W

RDC320T66W

1000
1200
1600
2000

RP6R20A100
RP6R20A120
RP6R20A160
RP6R20A200

2500

RDC325T61W

RDC325T63W

RDC325T62W

RDC325T64W

RDC325T65W

RDC325T66W

1600
2000
2500

RP6R25A160
RP6R25A200
RP6R25A250

Instruction Leaflet/FRED Number 29C107 for Breaker; Number 29886 for Digitrip 610 Trip Unit

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

Cutler-Hammer

Molded Case Circuit Breakers
800-2500 Amperes

March 1999

97

Series C R-Frame

100% Rated Digitrip RMS 610 Circuit Breakers
The NEC allows the breaker to be rated at 100% of its frame size in an assembly, provided that 90°C wire is applied at
75°C ampacity. Order as individual components: Breaker Frame (which includes Trip Unit) and Rating Plug.
Maximum
Continuous
Ampere
Rating
@ 40°C

Circuit Breaker Frame Only

Digitrip Rating Plug Only

L
S
I
G

Fixed Rating Plug

– Adjustable Long Delay Pickup (Ir) with Adjustable Long Delay Time
– Adjustable Short Delay Pickup with Adjustable Short Delay Time (I 2t or Flat Response)
– Adjustable Instantaneous Pickup
– Adjustable Ground Fault Pickup with Adjustable Ground Fault Time Delay (I 2t or Flat Response)

LI

LS

LSI

LIG

LSG

Rated
Current (In)

Catalog
Number

LSIG

Catalog Number

3-Pole Standard Interrupting Capacity 600 Volt Ac Rated 65 kAIC @ 480 Vac
1600

CRD316T61W

CRD316T63W

CRD316T62W

CRD316T64W

CRD316T65W

CRD316T66W

800
1000
1200
1600

RP6R16A080
RP6R16A100
RP6R16A120
RP6R16A160

2000

CRD320T61W

CRD320T63W

CRD320T62W

CRD320T64W

CRD320T65W

CRD320T66W

1000
1200
1600
2000

RP6R20A100
RP6R20A120
RP6R20A160
RP6R20A200

3-Pole High Interrupting Capacity 600 Volt Ac Rated 100 kAIC @ 480 Vac
1600

CRDC316T61W

CRDC316T63W

CRDC316T62W

CRDC316T64W

CRDC316T65W

CRDC316T66W

800
1000
1200
1600

RP6R16A080
RP6R16A100
RP6R16A120
RP6R16A160

2000

CRDC320T61W

CRDC320T63W

CRDC320T62W

CRDC320T64W

CRDC320T65W

CRDC320T66W

1000
1200
1600
2000

RP6R20A100
RP6R20A120
RP6R20A160
RP6R20A200

Instruction Leaflet/FRED Number 29C107 for Breaker; Number 29886 for Digitrip 610 Trip Unit

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

98

Cutler-Hammer

Molded Case Circuit Breakers
800-2500 Amperes

March 1999

Series C R-Frame

Digitrip RMS 810 Electronic Circuit Breakers with Interchangeable Rating Plugs
Order as individual components: Breaker Frame (which includes Trip Unit) and Rating Plug.
Maximum
Continuous
Ampere
Rating
@ 40°C

Circuit Breaker Frame Only

Digitrip Rating Plug Only

L
S
I
G

Fixed Rating Plug

– Adjustable Long Delay Pickup (Ir) with Adjustable Long Delay Time
– Adjustable Short Delay Pickup with Adjustable Short Delay Time (I 2t or Flat Response)
– Adjustable Instantaneous Pickup
– Adjustable Ground Fault Pickup with Adjustable Ground Fault Time Delay (I 2t or Flat Response)

LI

LS

LSI

LIG

LSG

Rated
Current (In)

Catalog
Number

LSIG

Catalog Number

3-Pole Standard Interrupting Capacity 600 Volt Ac Rated 65 kAIC @ 480 Vac
1600

RD316T81W

RD316T83W

RD316T82W

RD316T84W

RD316T85W

RD316T86W

800
1000
1200
1600

RP6R16A080
RP6R16A100
RP6R16A120
RP6R16A160

2000

RD320T81W

RD320T83W

RD320T82W

RD320T84W

RD320T85W

RD320T86W

1000
1200
1600
2000

RP6R20A100
RP6R20A120
RP6R20A160
RP6R20A200

2500

RD325T81W

RD325T83W

RD325T82W

RD325T84W

RD325T85W

RD325T86W

1600
2000
2500

RP6R25A160
RP6R25A200
RP6R25A250

3-Pole High Interrupting Capacity 600 Volt Ac Rated 100 kAIC @ 480 Vac
1600

RDC316T81W

RDC316T83W

RDC316T82W

RDC316T84W

RDC316T85W

RDC316T86W

800
1000
1200
1600

RP6R16A080
RP6R16A100
RP6R16A120
RP6R16A160

2000

RDC320T81W

RDC320T83W

RDC320T82W

RDC320T84W

RDC320T85W

RDC320T86W

1000
1200
1600
2000

RP6R20A100
RP6R20A120
RP6R20A160
RP6R20A200

2500

RDC325T81W

RDC325T83W

RDC325T82W

RDC325T84W

RDC325T85W

RDC325T86W

1600
2000
2500

RP6R25A160
RP6R25A200
RP6R25A250

Instruction Leaflet/FRED Number 29C107 for Breaker; Number 29888 for Digitrip 810 Trip Unit

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

Cutler-Hammer

Molded Case Circuit Breakers
800-2500 Amperes

March 1999

99

Series C R-Frame

100% Rated Digitrip RMS 810 Circuit Breakers
The NEC allows the breaker to be rated at 100% of its frame size in an assembly, provided that 90°C wire is applied at
75°C ampacity. Order as individual components: Breaker Frame (which includes Trip Unit) and Rating Plug.
Maximum
Continuous
Ampere
Rating
@ 40°C

Circuit Breaker Frame Only

Digitrip Rating Plug Only

L
S
I
G

Fixed Rating Plug

– Adjustable Long Delay Pickup (Ir) with Adjustable Long Delay Time
– Adjustable Short Delay Pickup with Adjustable Short Delay Time (I 2t or Flat Response)
– Adjustable Instantaneous Pickup
– Adjustable Ground Fault Pickup with Adjustable Ground Fault Time Delay (I 2t or Flat Response)

LI

LS

LSI

LIG

LSG

Rated
Current (In)

Catalog
Number

LSIG

Catalog Number

3-Pole Standard Interrupting Capacity 600 Volt Ac Rated 65 kAIC @ 480 Vac
1600

CRD316T81W

CRD316T83W

CRD316T82W

CRD316T84W

CRD316T85W

CRD316T86W

800
1000
1200
1600

RP6R16A080
RP6R16A100
RP6R16A120
RP6R16A160

2000

CRD320T81W

CRD320T83W

CRD320T82W

CRD320T84W

CRD320T85W

CRD320T86W

1000
1200
1600
2000

RP6R20A100
RP6R20A120
RP6R20A160
RP6R20A200

3-Pole High Interrupting Capacity 600 Volt Ac Rated 100 kAIC @ 480 Vac
1600

CRDC316T81W

CRDC316T83W

CRDC316T82W

CRDC316T84W

CRDC316T85W

CRDC316T86W

800
1000
1200
1600

RP6R16A080
RP6R16A100
RP6R16A120
RP6R16A160

2000

CRDC320T81W

CRDC320T83W

CRDC320T82W

CRDC320T84W

CRDC320T85W

CRDC320T86W

1000
1200
1600
2000

RP6R20A100
RP6R20A120
RP6R20A160
RP6R20A200

Instruction Leaflet/FRED Number 29C107 for Breaker; Number 29888 for Digitrip 810 Trip Unit

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

100

Cutler-Hammer

Molded Case Circuit Breakers
800-2500 Amperes

March 1999

Series C R-Frame

Digitrip RMS 910 Electronic Circuit Breakers with Interchangeable Rating Plugs
Order as individual components: Breaker Frame (which includes Trip Unit) and Rating Plug.
Maximum
Continuous
Ampere
Rating
@ 40°C

Circuit Breaker Frame Only

Digitrip Rating Plug Only

L
S
I
G

Fixed Rating Plug

– Adjustable Long Delay Pickup (Ir) with Adjustable Long Delay Time
– Adjustable Short Delay Pickup with Adjustable Short Delay Time (I 2t or Flat Response)
– Adjustable Instantaneous Pickup
– Adjustable Ground Fault Pickup with Adjustable Ground Fault Time Delay (I 2t or Flat Response)

LI

LS

LSI

LIG

LSG

Rated
Current (In)

Catalog
Number

LSIG

Catalog Number

3-Pole Standard Interrupting Capacity 600 Volt Ac Rated 65 kAIC @ 480 Vac
1600

RD316T91W

RD316T93W

RD316T92W

RD316T94W

RD316T95W

RD316T96W

800
1000
1200
1600

RP6R16A080
RP6R16A100
RP6R16A120
RP6R16A160

2000

RD320T91W

RD320T93W

RD320T92W

RD320T94W

RD320T95W

RD320T96W

1000
1200
1600
2000

RP6R20A100
RP6R20A120
RP6R20A160
RP6R20A200

2500

RD325T91W

RD325T93W

RD325T92W

RD325T94W

RD325T95W

RD325T96W

1600
2000
2500

RP6R25A160
RP6R25A200
RP6R25A250

3-Pole High Interrupting Capacity 600 Volt Ac Rated 100 kAIC @ 480 Vac
1600

RDC316T91W

RDC316T93W

RDC316T92W

RDC316T94W

RDC316T95W

RDC316T96W

800
1000
1200
1600

RP6R16A080
RP6R16A100
RP6R16A120
RP6R16A160

2000

RDC320T91W

RDC320T93W

RDC320T92W

RDC320T94W

RDC320T95W

RDC320T96W

1000
1200
1600
2000

RP6R20A100
RP6R20A120
RP6R20A160
RP6R20A200

2500

RDC325T91W

RDC325T93W

RDC325T92W

RDC325T94W

RDC325T95W

RDC325T96W

1600
2000
2500

RP6R25A160
RP6R25A200
RP6R25A250

Instruction Leaflet/FRED Number 29C107 for Breaker; Number 29889 for Digitrip 910 Trip Unit

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

Cutler-Hammer

Molded Case Circuit Breakers
800-2500 Amperes

March 1999

101

Series C R-Frame

100% Rated Digitrip RMS 910 Circuit Breakers
The NEC allows the breaker to be rated at 100% of its frame size in an assembly, provided that 90°C wire is applied at
75°C ampacity. Order as individual components: Breaker Frame (which includes Trip Unit) and Rating Plug.
Maximum
Continuous
Ampere
Rating
@ 40°C

Circuit Breaker Frame Only

Digitrip Rating Plug Only

L
S
I
G

Fixed Rating Plug

– Adjustable Long Delay Pickup (Ir) with Adjustable Long Delay Time
– Adjustable Short Delay Pickup with Adjustable Short Delay Time (I 2t or Flat Response)
– Adjustable Instantaneous Pickup
– Adjustable Ground Fault Pickup with Adjustable Ground Fault Time Delay (I 2t or Flat Response)

LI

LS

LSI

LIG

LSG

Rated
Current (In)

Catalog
Number

LSIG

Catalog Number

3-Pole Standard Interrupting Capacity 600 Volt Ac Rated 65 kAIC @ 480 Vac
1600

CRD316T91W

CRD316T93W

CRD316T92W

CRD316T94W

CRD316T95W

CRD316T96W

800
1000
1200
1600

RP6R16A080
RP6R16A100
RP6R16A120
RP6R16A160

2000

CRD320T91W

CRD320T93W

CRD320T92W

CRD320T94W

CRD320T95W

CRD320T96W

1000
1200
1600
2000

RP6R20A100
RP6R20A120
RP6R20A160
RP6R20A200

3-Pole High Interrupting Capacity 600 Volt Ac Rated 100 kAIC @ 480 Vac
1600

CRDC316T91W

CRDC316T93W

CRDC316T92W

CRDC316T94W

CRDC316T95W

CRDC316T96W

800
1000
1200
1600

RP6R16A080
RP6R16A100
RP6R16A120
RP6R16A160

2000

CRDC320T91W

CRDC320T93W

CRDC320T92W

CRDC320T94W

CRDC320T95W

CRDC320T96W

1000
1200
1600
2000

RP6R20A100
RP6R20A120
RP6R20A160
RP6R20A200

Instruction Leaflet/FRED Number 29C107 for Breaker; Number 29889 for Digitrip 910 Trip Unit

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

102

Cutler-Hammer

Molded Case Circuit Breakers
800-2500 Amperes

March 1999

Series C R-Frame

Digitrip OPTIM Electronic Circuit Breakers with Interchangeable Rating Plugs
Order as individual components: Breaker Frame (which includes Trip Unit) and Rating Plug.
Maximum
Continuous
Ampere
Rating
@ 40°C

Circuit Breaker Frame Only

Digitrip OPTIM Rating Plug Only

L
S
I
G
A

Fixed Rating Plug

– Adjustable Long Delay Pickup (Ir) with Adjustable Long Delay Time
– Adjustable Short Delay Pickup with Adjustable Short Delay Time (I 2t or Flat Response)
– Adjustable Instantaneous Pickup
– Adjustable Ground Fault Pickup with Adjustable Ground Fault Time Delay (I 2t or Flat Response)
– Adjustable Ground Fault Alarm with Adjustable Ground Fault Time Delay (I 2t or Flat Response)

LSIA 750

LSIG 750

LSIA 1050

Ampere
Rating

Catalog
Number

LSIG 1050

Catalog Number

3-Pole Standard Interrupting Capacity 600 Volt Ac Rated 65 kAIC @ 480 Vac
1600

RD316T77W

RD316T76W

RD316T107W

RD316T106W

800
1000
1200
1600

ORPR16A080
ORPR16A100
0RPR16A120
0RPR16A160

2000

RD320T77W

RD320T76W

RD320T107W

RD320T106W

1000
1200
1600
2000

0RPR20A100
0RPR20A120
0RPR20A160
0RPR20A200

2500

RD325T77W

RD325T76W

RD325T107W

RD325T106W

1600
2000
2500

0RPR25A160
0RPR25A200
0RPR25A250

3-Pole High Interrupting Capacity 600 Volt Ac Rated 100 kAIC @ 480 Vac
1600

RDC316T77W

RDC316T76W

RDC316T107W

RDC316T106W

800
1000
1200
1600

ORPR16A080
ORPR16A100
0RPR16A120
0RPR16A160

2000

RDC320T77W

RDC320T76W

RDC320T107W

RDC320T106W

1000
1200
1600
2000

0RPR20A100
0RPR20A120
0RPR20A160
0RPR20A200

2500

RDC325T77W

RDC325T76W

RDC325T107W

RDC325T106W

1600
2000
2500

0RPR25A160
0RPR25A200
0RPR25A250

Instruction Leaflet/FRED Number 29C107 for Breaker; Number 29C891 for OPTIM Trip Unit

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

Cutler-Hammer

Molded Case Circuit Breakers
800-2500 Amperes

March 1999

103

Series C R-Frame

100% Rated 600 Volt AC Digitrip OPTIM Circuit Breakers with Interchangeable Rating Plugs
Order as individual components: Breaker Frame (which includes Trip Unit) and Rating Plug.
Maximum
Continuous
Ampere
Rating
@ 40°C

Circuit Breaker Frame Only

Digitrip OPTIM Rating Plug Only

L
S
I
G
A

Fixed Rating Plug

– Adjustable Long Delay Pickup (Ir) with Adjustable Long Delay Time
– Adjustable Short Delay Pickup with Adjustable Short Delay Time (I 2t or Flat Response)
– Adjustable Instantaneous Pickup
– Adjustable Ground Fault Pickup with Adjustable Ground Fault Time Delay (I 2t or Flat Response)
– Adjustable Ground Fault Alarm with Adjustable Ground Fault Time Delay (I 2t or Flat Response)

LSIA 750

LSIG 750

LSIA 1050

Ampere
Rating

Catalog
Number

LSIG 1050

3-Pole Standard Interrupting Capacity 600 Volt Ac Rated 65 kAIC @ 480 Vac
1600

CRD316T77W

CRD316T76W

CRD316T107W

CRD316T106W

800
1000
1200
1600

ORPR16A080
ORPR16A100
0RPR16A120
0RPR16A160

2000

CRD320T77W

CRD320T76W

CRD320T107W

CRD320T106W

1000
1200
1600
2000

0RPR20A100
0RPR20A120
0RPR20A160
0RPR20A200

3-Pole High Interrupting Capacity 600 Volt Ac Rated 100 kAIC @ 480 Vac
1600

CRDC316T77W

CRDC316T76W

CRDC316T107W

CRDC316T106W

800
1000
1200
1600

ORPR16A080
ORPR16A100
0RPR16A120
0RPR16A160

2000

CRDC320T77W

CRDC320T76W

CRDC320T107W

CRDC320T106W

1000
1200
1600
2000

0RPR20A100
0RPR20A120
0RPR20A160
0RPR20A200

Instruction Leaflet/FRED Number 29C107 for Breaker; Number 29C891 for OPTIM Trip Unit

PG.74A.01.T.E

104

Cutler-Hammer

Molded Case Circuit Breakers
800-2500 Amperes

March 1999

Series C R-Frame

Molded Case Switches

Line and Load Terminals

For UL listed, series tested molded
case switch application data, refer to
Cutler-Hammer.

Line and load terminals provide wire
connecting capabilities for specific
ranges of continuous current ratings and wire types. All terminals
comply with Underwriters Laboratories, Inc. Standards UL486A and
UL486B and CSA C22.2 No. 65M.
Unless otherwise specified, R-frame

Continuous Complete without Terminals
Ampere
3-Pole
4-Pole
Rating
@ 40°C
Catalog Number

1600

Type RD – HIgh Instantaneous (K)

2000

Type RD – HIgh Instantaneous (K)

RD316WK
RD320WK
2500

RD416WK
RD420WK

Type RD – HIgh Instantaneous (K)

–

–

Note: Molded case switch may trip
above 17500 amperes.
Instruction Leaflet/FRED Number 29C106 for
Molded Case Switch

circuit breaker line load terminals
are shipped separately for field
installation.
Ordering Information
R-frame circuit breakers have Cu/AI
terminals as standard and Cu only
terminals as an option. Specify if
factory installation is required.

Line and Load Terminals
Maximum
Breaker Amperes

Terminal
Body Material

Wire
Type

Hardware

AWG/kcmil Wire
Range/No. Conductors

Metric Wire
Range mm2

Catalog
Number

Wire Terminals
1600
1600
2000

Aluminum
Copper
Aluminum

Cu/AI
Cu
Cu/AI

English
English
English

500-1000 (4)
1-600 (4)
2-600 (6)

300-500
50-300
35-300

TA1600RD
T1600RD
TA2000RD➀

–
–
–

English
English
English

–
–
–

–
–
–

B2016RD
B2016RDL➁
B2500RD➂

Rear Connectors
2000
2000
2500

Copper
Copper
Copper

Breaker Line/Load
Conductors

TA2000RD

➀ Catalog number includes bus connection,
terminals, and hardware for either line side
or load side of 3-pole breaker.

➁ For use with 100% rated 1600A and 2000A
frame. Do not order separately unless for replacement purposes. Is included in breaker
carton when 100% rated device is ordered.

➂ For use with 2500-amp frame. Do not order
separately unless for replacement purposes.
Included in breaker carton when 2500A
breaker is ordered.

PG.74A.01.T.E

Cutler-Hammer

Molded Case Circuit Breakers
800-2500 Amperes

March 1999

Series C R-Frame

Catalog Numbering System
This information is presented only as an aid to understanding catalog numbers. It is not to be used to build catalog
numbers for circuit breakers or trip units.
Circuit Breaker/Frame Catalog Number
RD 3 16

T32

W

Circuit
Breaker/
Frame Type

Number
of Poles

Circuit Breaker/
Frame Ampere
Rating

Trip Type➀

Suffix

RD
RDC
CRD
CRDC

3: 3 Poles
4: 4 Poles

16: 1600A
20: 2000A
25: 2500A

T32: Digitrip RMS
310 LSI
T53: Digitrip RMS
510 LS
T65: Digitrip RMS
610 LSG
T86: Digitrip RMS
810 LSIG
T96: Digitrip RMS
910 LSIG
T77: Digitrip OPTIM
750 LSIA
T106: Digitrip OPTIM
1050 LSIG

W: Without
Terminals
P: 100% Protected
Neutral Pole
R: Ground Fault
Remote (310 Only)
K: Molded Case
Switch

Dimensions/Weights
Dimensions, Inches (mm)
Number of Poles

Width

Height

Depth

3

15.5
(394)

16
(406)

9.75
(248)

4

20
(508)

16
(406)

9.75
(248)

Approximate Shipping Weight, Lbs. (kg)
Breaker
Type

Complete Breaker
Number of Poles
3

4

1600A
RD, CRD, RDC, CRDC

102
(46.266)

135
(61.235)

RD, RDC

102
(46.266)

135
(61.235)

CRD, CRDC

130
(58.967)

175
(79.378)

RD, RDC

135
(61.235)

182
(82.553)

2000A

2500A

➀ For complete list of available trip types refer
to pages 91 through 103.

PG.74A.01.T.E

105

106

Cutler-Hammer

Molded Case Circuit Breakers
800-2500 Amperes

March 1999

Series C R-Frame

Allowable Accessory Combinations
Different combinations of accessories can be supplied, depending on the types of accessories and the number of poles
in the circuit breaker.
Reference
Page

3-Pole
Left

4-Pole
Center

Right

Left

Center

Right

Neu.

Internal Accessories
Alarm Lockout (Make/Break)

141

■

■

Alarm Lockout (2Make/2Break)

141

■

■

Auxiliary Switch (2A, 2B)

144

■

■

Auxiliary Switch (4A, 4B)

144

■

■

Shunt Trip – Standard

151

■

■

Shunt Trip – Low Energy

152

■

■

Undervoltage Release Mechanism

159

■

■

Accessory Terminal Block➁

160

■

■

External Accessories
Base Mounting Hardware

163

Padlockable Handle Lock Hasp

169

●

●

Key Interlock Kit

170

■

■

Walking Beam Interlock

171

■

Electrical (Motor) Operator

173

■

Drawout Cassette

164

●

Handle Mechanisms

178

■

Handle Extension➀

182

■

■

Solid-State (Electronic) Portable Test Kit (310 Only)

184

●

●

Breaker Interface Module (BIM)

185

●

Digitrip OPTIMizer

185

●

Auxiliary Power Module

185

●

Cutler-Hammer PowerNet Software

185

●

Special Calibration

186

●

●

Moisture Fungus Treatment

186

●

●

Freeze-Tested Circuit Breakers

186

●

●

Marine Application

186

●

●

■

OPTIM System Components

Modifications (Refer to Cutler-Hammer)

■ Applicable in indicated pole position

● Accessory available/Modification available

➀ Included with breaker.
➁ Mounts outside breaker.

PG.74A.01.T.E

Cutler-Hammer

Molded Case Circuit Breakers
Series C Motor Circuit Protectors

March 1999

107

General Information
Designated as the Cutler-Hammer Types GMCP, HMCP, the
Series C instantaneous-only motor circuit protector (MCP)
is available in ratings from 3A to 600A for motor starter
sizes 0 through 6. The MCP is designed to comply with
the applicable requirements of Underwriters Laboratories,
Inc. Standard UL489, Canadian Standards Association
Standard C22.2 No. 5, and International Electrotechnical
Commission Recommendations IEC 157-1.

Series C Motor Circuit Protectors

An innovative design of internal components allows higher
MCP-starter combination interrupting ratings. The MCP is
marked to permit proper electrical application within the
assigned equipment ratings.
The MCP is a recognized component (UL File E7819) and
complies with the applicable requirements of Underwriters
Laboratories, Inc. Standard UL489. It is also designed to
comply with the applicable requirements of Canadian
Standards Association Standard C22.2 No. 5, International Electrotechnical Commission Recommendations
IEC 157-1, and nameplates bear the CE marking.

Catalog Numbering System
This information is presented only as an aid to understanding catalog numbers. It is not to be used to build
catalog numbers for circuit breakers or trip units.
Motor Circuit Protector Catalog Number
HMCP 003 A0 C
Motor
Circuit
Protective
Type

Contin- Magnetic Trip
uous
Range/NEMA
Ampere Starter Size
Rating

HMCP: 3 Poles 003
HM2P: 2 Poles➀ 007
HMCPS: 3 Poles 015
025
030
050
070
100
150
250
400

600

A0:
C0:
E0:
D0:
H1:
G2:
K2:
J2:
M2:
L3:
R3:
T4:
U4:
A5:
C5:
D5:
F5:
G5:
J5:
K5:
L5:
W5:
N5:
R5:
X5:
L6:

9-30/0
C: Non-Aluminum
21-70/0
Terminals
45-150/0
W: W/O Terminals
40-60/0
X: Load Terminals Only
90-300/1
Y: Line Terminals Only
80-120/2
S: Stainless Steel Termi150-500/2
nals (150A Frame Only)
115-170/2
No Suffix: Standard
210-700/2
Terminals on Line
160-240/3
and Load
300-1000/3
450-1500/4
750-2500/4
350-700/5
450-900/5
500-1000/5
625-1250/5
750-1500/5
875-1750/5
1000-2000/5
1125-2250/5
1250-2500/5
1500-3000/5
1750-3500/5
2000-4000/5
1800-6000/6 Electronic)

➀ On J- and K-Frame HMCPs only.

PG.74A.01.T.E

Suffix

GMCP 003 A0 C
Motor
Circuit
Protective
Device

GMCP:

Continuous
Ampere
Rating

3 Poles 003
007
015
030
050
060
063

Magnetic Trip
Range/NEMA
Starter Size

Suffix

A0:
C0:
E0:
H1:
K2:
J2:
M2:

C: Non-Aluminum
Terminals

15-30/0
35-70/0
75-150/0
150-300/1
250-500/2
300-600/2
320-630/2

Time/Current Curves, Dimension Sheets, Application Data

108

Cutler-Hammer

Molded Case Circuit Breakers
Series C Motor Circuit Protectors

March 1999

G-Frame

Modifications for GMCP

480 Vac Maximum, 250 Vdc Maximum
MCP
Catalog Number

GMCP003A0C

GMCP007C0C

GMCP015E0C

GMCP030H1C

GMCP050K2C

GMCP060J2C

GMCP063M2C

NEMA
Continuous
Starter Size Amperes

0

0

0

1

2

3

3

3

7

15

30

50

60

63

Cam
Motor Full Load
MCP Trip
Setting Center Amperes➄ Setting

A
B
C
D
E
F

1.1
1.3
1.6
1.8
2.0
2.3

-

1.2
1.5
1.7
1.9
2.2
2.5

15
18
21
24
27
30

A
B
C
D
E
F

2.6
3.2
3.7
4.3
4.8
5.3

-

3.1
3.6
3.9
4.7
5.2
5.7

35
42
49
56
63
70

A
B
C
D
E
F

5.7
6.9
8.0
9.2
10.4
11.5

- 6.8
- 7.9
- 9.1
- 10.3
- 11.4
- 12.6

75
90
105
120
135
150

A
B
C
D
E
F

11.5
13.8
16.1
18.4
20.7
23.0

- 13.7
- 16.0
- 18.3
- 20.6
- 22.9
- 25.2

150
180
210
240
270
300

A
B
C
D
E
F

19.3
23.0
26.9
30.7
34.6
38.4

- 22.9
- 26.8
- 30.6
- 34.5
- 38.3
- 42.1

250
300
350
400
450
500

A
B
C
D
E
F

23.1
27.7
32.3
36.9
41.5
46.2

- 27.5
- 32.2
- 36.7
- 41.4
- 46.0
- 50.5

300
360
420
480
540
600

A
B
C
D
E
F

24.2
29.1
33.9
38.8
43.6
48.5

- 32.1
- 34.8
- 39.4
- 46.4
- 48.9
- 53.7

320
380
440
500
570
630

Internal Accessories
These modifications must be factory installed➀.
Type
Accessory

Electrical Ratings

Shunt Trip➂
Shunt Trip➂

120
240

50/60 Hz
50/60 Hz

1.1
2.1

Auxiliary Switch➃ 240
Auxiliary Switch➃ 240

50/60 Hz
50/60 Hz

6.0
6.0

1a/1b
2a/2b

Alarm Switch➃

240

50/60 Hz

Alarm Switch➃
Alarm Switch
Combination

240

50/60 Hz

Volts Frequency Amperes

Contact
Arrangement

Style
Number

Factory
Suffix

1373D62G18
1373D62G19

S5
S6

1288C74G03
1288C73G03

A3
A6

6.0

Make/Break 1288C75G03

B3

6.0

1a/1b
1288C76G09
Make/Break

B13

Note: No UVR available on GMCP.
Instruction Leaflet/FRED Number 15552 for Alarm Switch
Instruction Leaflet/FRED Number 15551 for Auxiliary Switch
Instruction Leaflet/FRED Number 15550 for Shunt Trip

External Mounted Accessories
Description

Number Units
in Package

Lock Dog (Non-Padlockable)
Mounting Hardware
DIN Rail Adapter➁

Style Number

1
1
10

1294C01H01
624B375G23
1225C79G02

Instruction Leaflet/FRED Number 29C191 (DIN Rail Adapter)

Vari-Depth Handle Mechanism➅
Description

Catalog Number

For Type 1 use

HRGMV11L

For Type 3R, 4X, 12 use

HRGMV14L

Close Coupled Black with Gray Handle

HRGMC10

Close Coupled Red with Yellow Handle

HRGMC30

Instruction Leaflet/FRED Number 15579

➀ Only one accessory may be installed in
GMCP.
➁ For use with standard 35 mm DIN rail such
as, 35 x 7.5 or 15 mm per DIN EN50022.
➂ LH only.
➃ RH only.
➄ Motor FLA ranges are typical. The corresponding trip setting is at 13 times the minimum FLA value shown. Where a 13 times
setting is required for an intermediate FLA
value, alternate cam settings and/or MCP
ratings should be used.
➅ For use with GMCP only.

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

Cutler-Hammer

Molded Case Circuit Breakers
Series C Motor Circuit Protectors

March 1999

109

F-Frame

F-Frame (Continued)

600 Vac Maximum, 250 Vdc Maximum

600 Vac Maximum, 250 Vdc Maximum

MCP
Catalog Number

HMCP003A0C

HMCP007C0C

HMCP015E0C

HMCP030H1C

HMCP050K2C

HMCP070M2C

HMCP100R3C

NEMA
Continuous
Starter Size Amperes

0

0

0

1

2

2

3

3

7

15

30

50

70

100

Cam
Motor Full Load
MCP Trip
Setting Center Amperes➀ Setting➁

A
B
C
D
E
F
G
H

.69
.92
1.1
1.3
1.6
1.8
2.0
2.3

-

.91
1.0
1.2
1.5
1.7
1.9
2.2
2.5

9
12
15
18
21
24
27
30

A
B
C
D
E
F
G
H

1.5
2.1
2.6
3.2
3.7
4.3
4.8
5.3

-

2.0
2.5
3.1
3.6
3.9
4.7
5.2
5.7

21
28
35
42
49
56
63
70

A
B
C
D
E
F
G
H

3.4
4.6
5.7
6.9
8.0
9.2
10.4
11.5

-

4.5
5.6
6.8
7.9
9.1
10.3
11.4
12.6

45
60
75
90
105
120
135
150

A
B
C
D
E
F
G
H

6.9
9.2
11.5
13.8
16.1
18.4
20.7
23.0

-

9.1
11.4
13.7
16.0
18.3
20.6
22.9
25.2

90
120
150
180
210
240
270
300

A
B
C
D
E
F
G
H

11.5
15.3
19.2
23.0
26.9
30.7
34.6
38.4

-

15.2
19.1
22.9
26.8
30.6
34.5
38.3
42.1

150
200
250
300
350
400
450
500

A
B
C
D
E
F
G
H

16.1
21.5
26.9
32.3
37.6
43.0
48.4
53.8

-

21.4
26.8
32.2
37.5
42.9
48.3
53.7
59.1

210
280
350
420
490
560
630
700

A
B
C
D
E
F
G
H

23.0
30.7
38.4
46.1
53.8
61.5
69.2
76.9

-

30.6
38.3
46.0
53.7
61.4
69.1
76.8
84.5

300
400
500
600
700
800
900
1000

MCP
Catalog Number

HMCP150T4C

HMCP150U4C

NEMA
Continuous
Starter Size Amperes

4

4

Cam
Motor Full Load
MCP Trip
Setting Center Amperes➀ Setting➁

150

150

PG.74A.01.T.E

34.6
46.1
57.6
69.2
80.7
92.3
103.8
115.3

- 46.0
- 57.5
- 69.1
- 80.6
- 92.2
-103.7
-115.2
-126.7

450
600
750
900
1050
1200
1350
1500

A
B
C
D
E
F
G
H

57.0
76.0
96.0
115.0

- 75.0
- 95.0
-114.0
-130.7

750
1000
1250
1500
1750
2000
2250
2500

➂
➂
➂
➂

Instruction Leaflet/FRED Number 29C401

Special Low Magnetic Protection Application MCP
600 Vac Maximum, 250 Vdc Maximum
MCP
Catalog Number

HMCPO25D0C

HMCP050G2C

HMCP070J2C

HMCP100L3C

NEMA
Continuous
Starter Size Amperes

–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–

Cam
Motor Full Load
Setting Center Amperes

25A

50A

70A

100A

Instruction Leaflet/FRED Number 29C407
➀ Motor FLA ranges are typical. The corresponding trip setting is at
13 times the minimum FLA value shown. Where a 13 times setting is
required for an intermediate FLA value, alternate cam settings and/or
MCP ratings should be used.
➁ For Dc applications, actual trip levels are approximately 40% higher
than values shown.
➂ Settings above 130 amperes are for special applications. NEC Article
430-110(a) requires the ampere rating of the disconnecting means to be
not less than 115% of the motor full load ampere rating.

A
B
C
D
E
F
G
H

MCP Trip
Setting➁

A
B
C
D
E
F
G
H

–
–
–
–
–
–
–
–

40
43
46
49
52
55
58
60

A
B
C
D
E
F
G
H

–
–
–
–
–
–
–
–

80
87
93
98
103
109
115
120

A
B
C
D
E
F
G
H

–
–
–
–
–
–
–
–

115
122
130
139
145
153
160
170

A
B
C
D
E
F
G
H

–
–
–
–
–
–
–
–

160
174
185
196
207
218
229
240

Time/Current Curves, Dimension Sheets, Application Data

110

Cutler-Hammer

Molded Case Circuit Breakers
Series C Motor Circuit Protectors

March 1999

MCPs for Application with Motor Starters Equipped with
Electronic Overload Relays

Type ELC Current Limiter Attachment (Size 0-4)

600 Vac Maximum, 250 Vdc Maximum
MCP
Catalog Number

HMCPS003A0C

HMCPS007C0C

HMCPS015E0C

HMCPS030H1C

HMCPS050K2C

HMCPS100R3C

HMCPS150T4C

HMCPS150U4C

NEMA
Continuous
Starter Size Amperes

0

0

0

1

2

3

4

4

Cam
Motor Full Load
MCP Trip
Setting Center Amperes➀ Setting➁

3

7

15

30

50

100

150

150

Instruction Leaflet/FRED Number 29C401

A
B
C
D
E
F
G
H

.69
.92
1.1
1.3
1.6
1.8
2.0
2.3

-

.91
1.0
1.2
1.5
1.7
1.9
2.2
2.5

9
12
15
18
21
24
27
30

A
B
C
D
E
F
G
H

1.5
2.1
2.6
3.2
3.7
4.3
4.8
5.3

-

2.0
2.5
3.1
3.6
3.9
4.7
5.2
5.7

21
28
35
42
49
56
63
70

A
B
C
D
E
F
G
H

3.4
4.6
5.7
6.9
8.0
9.2
10.4
11.5

-

4.5
5.6
6.8
7.9
9.1
10.3
11.4
12.6

45
60
75
90
105
120
135
150

A
B
C
D
E
F
G
H

6.9
9.2
11.5
13.8
16.1
18.4
20.7
23.0

-

9.1
11.4
13.7
16.0
18.3
20.6
22.9
25.2

90
120
150
180
210
240
270
300

A
B
C
D
E
F
G
H

11.5
15.3
19.2
23.0
26.9
30.7
34.6
38.4

-

15.2
19.1
22.9
26.8
30.6
34.5
38.3
42.1

150
200
250
300
350
400
450
500

A
B
C
D
E
F
G
H

23.0
30.7
38.4
46.1
53.8
61.5
69.2
76.9

-

30.6
38.3
46.0
53.7
61.4
69.1
76.8
84.5

300
400
500
600
700
800
900
1000

A
B
C
D
E
F
G
H

34.6
46.1
57.6
69.2
80.7
92.3
103.8
115.3

- 46.0
- 57.5
- 69.1
- 80.6
- 92.2
-103.7
-115.2
-126.7

450
600
750
900
1050
1200
1350
1500

A
B
C
D
E
F
G
H

57.0
76.0
96.0
115.0

- 75.0
- 95.0
-114.0
-130.7

750
1000
1250
1500
1750
2000
2250
2500

➂
➂
➂
➂

The type ELC current limiter attachment for the Series C
MCP is designed to provide increased interrupting capacity. The combination may be used for the application up
to 200,000A symmetrical at 600 Vac making the MCP suitable for use in network distribution systems or other
applications where unusually high fault currents are
available. The current limiter connects to the load end
of the MCP and is provided with terminals suitable for
copper or aluminum conductors. (See table).
Limiters are coordinated with the MCP so that normal
fault currents are interrupted automatically by the MCP
without any damage to the limiter. Only the rare very
high fault is opened by the limiter. Faults that are interrupted by the limiter are interrupted by the limiter also
magnetically trip the MCP, opening all three poles,
preventing single-phase operation.
Each of the three poles of the type ELC limiter is
equipped with an indicator that extends when a fault is
interrupted by the limiter.
Type ELC Current Limiter Terminal Wire Sizes➃
Type ELC Current Standard Aluminum Terminals
Limiter MaxiWire Range
Metric (mm2)
mum Amperes
AWG

#14-2
#1-4/0
#1-4/0

50
100
150

2.5-35
50-95
50-95

Nonstandard Terminals (Steel)
Wire Range
AWG

#14-2➄
–
–

Metric (mm2)

2.5-35
–
–

ELC Current Limiter Attachment
MCP Rating (Amperes)

Catalog Number

3
7
15
30
50
100
150

ELC3003R
ELC3007R
ELC3015R
ELC3030R
ELC3050R
ELC3100R
ELC3150R

Instruction Leaflet/FRED Number 29C401
➀ Motor FLA ranges are typical. The corresponding trip setting is at 13
times the minimum FLA value shown. Where a 13 times setting is
required for an intermediate FLA value, alternate cam settings and/or
MCP ratings should be used.
➁ For Dc applications, actual trip levels are approximately 40% higher than
values shown.
➂ Settings above 130 amperes are for special applications. NEC Article
430-110(a) requires the ampere rating of the disconnecting means to be
not less than 115% of the motor full load ampere rating.
➃ Terminal wire connectors are UL listed for standard stranded wire sizes
as defined in UL486A or UL486B.
➄ Optional on special order for copper cable only.

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

Cutler-Hammer

Molded Case Circuit Breakers
Series C Motor Circuit Protectors

March 1999

111

J-Frame
600 Vac Maximum, 250 Vdc Maximum
MCP
Catalog Number➀

NEMA
Continuous
Starter Size Amperes

HMCP250A5C

4
4
4
5
5
5
5
5
5

HMCP250C5C

5
5
5
5
5
5
5
5
5

HMCP250D5C

5
5
5
5
5
5
5
5
5

HMCP250F5C

5
5
5
5
5
5
5
5
5

HMCP250G5C

5
5
5
5
5
5
5
5
5

MCP Trip
Cam
Motor Full Load
Setting Center Amperes➁ Setting➂

250

A
B
C
D
E
F
G
H
I

27.0
30.8
33.9
37.0
40.4
43.9
47.0
50.8
53.9

-

30.7
33.8
36.9
40.3
43.8
46.9
50.7
53.8
57.2

350
400
440
480
525
570
610
660
700

250

A
B
C
D
E
F
G
H
I

34.7
38.9
43.5
47.7
52.3
56.6
60.8
65.0
69.3

-

38.8
43.4
47.6
52.2
56.5
60.7
64.9
69.2
73.5

450
505
565
620
680
735
790
845
900

250

A
B
C
D
E
F
G
H
I

38.5
43.5
48.1
53.1
57.7
62.4
67.4
72.0
77.0

-

43.4
48.0
53.0
57.6
62.3
67.3
71.9
76.9
81.6

500
565
625
690
750
810
875
935
1000

250

A
B
C
D
E
F
G
H
I

48.1
53.9
60.0
66.2
72.4
78.5
83.9
90.0
96.2

- 53.8
- 59.9
- 66.1
- 72.3
- 78.4
- 83.8
- 89.9
- 96.1
- 102.0

625
700
780
860
940
1020
1090
1170
1250

250

A
B
C
D
E
F
G
H
I

57.7
64.7
72.0
79.3
86.6
93.9
101.2
108.5
115.4

- 64.6
- 71.9
- 79.2
- 86.5
- 93.8
- 101.1
- 108.4
- 115.3
- 122.4

750
840
935
1030
1125
1220
1315
1410
1500

➀ Three-pole catalog numbers shown. Twopole catalog numbers begin with”HM2P” in
place of “HMCP.”
➁ Motor FLA ranges are typical. The corresponding trip setting is at 13 times the minimum FLA value shown. Where a 13 times
setting is required for an intermediate FLA
value, alternate cam settings and/or MCP
ratings should be used.
➂ For Dc applications, actual trip levels are
approximately 40% higher than values shown.

PG.74A.01.T.E

MCP
Catalog Number➀

NEMA
Continuous
Starter Size Amperes

HMCP250J5C

5
5
5
5
5
5
5
5
5

HMCP250K5C

5
5
5
5
5
5
5
5
5

HMCP250L5C

5
5
5
5
5
5
5
5
5

HMCP250W5C

5
5
5
5
5
5
5
5
5

MCP Trip
Cam
Motor Full Load
Setting Center Amperes➁ Setting➂

250

A
B
C
D
E
F
G
H
I

67.4
75.4
83.9
92.4
100.8
109.3
117.7
126.2
134.7

- 75.3
- 83.8
- 92.3
- 100.7
- 109.2
- 117.6
- 126.1
- 134.6
- 142.8

875
980
1090
1200
1310
1420
1530
1640
1750

250

A
B
C
D
E
F
G
H
I

77.0
86.6
96.2
105.8
115.4
125.0
134.7
144.3
153.9

- 86.6
- 96.1
- 105.7
- 115.3
- 124.9
- 134.6
- 144.2
- 153.8
- 163.3

1000
1125
1250
1375
1500
1625
1750
1875
2000

250

A
B
C
D
E
F
G
H
I

86.6
97.4
108.5
118.9
130.0
140.8
151.6
162.4
173.1

- 97.3
- 108.4
- 118.8
- 129.9
- 140.7
- 151.5
- 162.3
- 173.0
- 183.6

1125
1265
1410
1545
1690
1830
1970
2110
2250

250

A
B
C
D
E
F
G
H
I

96.2
108.1
120.0
132.4
144.3
156.2
168.1
180.0
192.4

- 108.0
- 119.9
- 132.3
- 144.2
- 156.1
- 168.0
- 179.9
- 192.3
- 204.0

1250
1405
1560
1720
1875
2030
2185
2340
2500

Instruction Leaflet/FRED Number 29C402

Time/Current Curves, Dimension Sheets, Application Data

112

Cutler-Hammer

Molded Case Circuit Breakers
Series C Motor Circuit Protectors

March 1999

K-Frame
600 Vac Maximum, 250 Vdc Maximum
MCP
Catalog Number➀

NEMA
Continuous
Starter Size Amperes

HMCP400D5C

5
5
5
5
5
5
5
5
5

HMCP400F5C

5
5
5
5
5
5
5
5
5

HMCP400G5C

5
5
5
5
5
5
5
5
5

HMCP400J5C

5
5
5
5
5
5
5
5
5

HMCP400K5C

5
5
5
5
5
5
5
5
5

MCP Trip
Cam
Motor Full Load
Setting Center Amperes➁ Setting➂

400

A
B
C
D
E
F
G
H
I

38.5
43.5
48.1
53.1
57.7
62.4
67.4
72.0
77.0

-

43.4
48.0
53.0
57.6
62.3
67.3
71.9
76.9
81.6

500
565
626
690
750
810
875
935
1000

400

A
B
C
D
E
F
G
H
I

48.1
53.9
60.0
66.2
72.4
78.5
83.9
90.0
96.2

- 53.8
- 59.9
- 66.1
- 72.3
- 78.4
- 83.8
- 89.9
- 96.1
- 102.0

625
700
780
860
940
1020
1090
1170
1250

400

A
B
C
D
E
F
G
H
I

57.7
64.7
72.0
79.3
86.6
93.9
101.2
108.5
115.4

- 64.6
- 71.9
- 79.2
- 86.5
- 93.8
- 101.1
- 108.4
- 115.3
- 122.4

750
840
935
1030
1125
1220
1315
1410
1500

400

A
B
C
D
E
F
G
H
I

67.4
75.4
83.9
92.4
100.8
109.3
117.7
126.2
134.7

- 75.3
- 83.8
- 92.3
- 100.7
- 109.2
- 117.6
- 126.1
- 134.6
- 142.8

875
980
1090
1200
1310
1420
1530
1640
1750

400

A
B
C
D
E
F
G
H
I

77.0
86.6
96.2
105.8
115.4
125.0
134.7
144.3
153.9

- 86.5
- 96.1
- 105.7
- 115.3
- 124.9
- 134.6
- 144.2
- 153.8
- 163.3

1000
1125
1250
1375
1500
1625
1750
1875
2000

MCP
Catalog Number➀

NEMA
Continuous
Starter Size Amperes

HMCP400L5C

5
5
5
5
5
5
5
5
5

HMCP400W5C

5
5
5
5
5
5
5
5
5

HMCP400N5C

5
5
5
5
5
5
5
5
5

HMCP400R5C

5
5
5
5
5
5
5
5
5

HMCP400X5C

5
5
5
5
5
5
5
5
5

MCP Trip
Cam
Motor Full Load
Setting Center Amperes➁ Setting➂

400

A
B
C
D
E
F
G
H
I

86.6
97.4
108.5
118.9
130.0
140.8
151.6
162.4
173.1

- 97.3
- 108.4
- 118.8
- 129.9
- 140.7
- 151.5
- 162.3
- 173.0
- 183.6

1125
1265
1410
1545
1690
1830
1970
2110
2250

400

A
B
C
D
E
F
G
H
I

96.2
108.1
120.0
132.4
144.3
156.2
168.1
180.0
192.4

- 108.0
- 119.9
- 132.3
- 144.2
- 156.1
- 168.0
- 179.9
- 192.3
- 204.0

1250
1405
1560
1720
1875
2030
2185
2340
2500

400

A
B
C
D
E
F
G
H
I

115.4
130.0
144.3
158.5
173.1
187.7
202.0
216.2
230.8

- 129.9
- 144.2
- 158.4
- 173.0
- 187.6
- 201.9
- 216.1
- 230.7
- 244.9

1500
1690
1875
2060
2250
2440
2625
2810
3000

400

A
B
C
D
E
F
G
H
I

134.7
151.6
168.5
185.4
202.0
218.9
235.8
252.7
269.3

- 151.5
- 168.4
- 185.3
- 201.9
- 218.8
- 235.7
- 252.6
- 269.2
- 285.7

1750
1970
2190
2410
2625
2845
3065
3285
3500

400

A
B
C
D
E
F
G
H
I

153.9
173.1
192.4
211.6
230.8
250.0
269.3
288.5
307.7

- 173.0
- 192.3
- 211.5
- 230.7
- 249.9
- 269.2
- 288.4
- 307.6
- 326.9

2000
2250
2500
2750
3000
3250
3500
3750
4000

Instruction Leaflet/FRED Number 29C403

L-Frame➃
600 Vac Maximum
MCP
Catalog Number

➀ Three-pole catalog numbers shown. Twopole catalog numbers begin with”HM2P” in
place of “HMCP.”
➁ Motor FLA ranges are typical. The corresponding trip setting is at 13 times the minimum FLA value shown. Where a 13 times
setting is required for an intermediate FLA
value, alternate cam settings and/or MCP
ratings should be used.
➂ For Dc applications, actual trip levels are
approximately 40% higher than values shown.
➃ Equipped with electronic trip device.

HMCP600L6W

NEMA
Continuous
Starter Size Amperes

6
6
6
6
6
6
6
6

MCP Trip
Cam
Motor Full Load
Setting Center Amperes➁ Setting

600

A
B
C
D
E
F
G
H

138.5
184.6
230.8
276.9
323.1
369.2
415.4
461.5

- 184.5
- 230.7
- 276.8
- 323.0
- 369.1
- 415.3
- 461.4
- 507.7

1800
2400
3000
3600
4200
4800
5400
6000

Instruction Leaflet/FRED Number 29C404

PG.74A.01.T.E

Cutler-Hammer
March 1999

Molded Case Circuit Breakers
Series C Earth Leakage Circuit Breakers

General Information

Applications

Series C Earth Leakage Breakers
offer superior Class 1 ground fault
protection and improved ground
fault coordination capability.

Three-Phase, Four-Wire Loads
For three-phase applications with
line-to-neutral loads, select 4-pole
earth leakage breakers and wire the
neutral through the fourth (right) pole.

Earth leakage ground fault protection
differs from other types of systems in
its level of sensitivity. The sensitivity
of traditional devices is limited by the
cumulative error of the residual current sensors and the placement of
the phase and neutral conductors
inside the current sensor.
Leakage breakers are zero sequence
sensing devices. They are factory
supplied with a single sensor and
ground fault relay built-in. This technique allows for protection sensitivities down to the 30 milliampere level.
Typical Series C Earth
Leakage Circuit Breaker

PG.74A.01.T.E

Leakage breakers are provided with a
full complement of easy adjustments. The ground fault pickup setting is adjustable from 0.03 to 30
amperes in eight steps, and the
ground fault time delay setting is
adjustable from instantaneous to 2.0
seconds in six steps. When the
pickup is set to 30 mA, the time delay
setting defaults internally to instantaneous only. Increased selectivity provides for improved coordination with
upstream and downstream ground
fault devices as well as the flexibility
to adjust for transient currents.

Three-Phase, Three-Wire Loads
For applications with only threephase, three-wire, line-to-line connected loads, select 3-pole earth
leakage breakers.
Single-Phase Loads
For single-phase, two-wire or threewire applications, use a 3-pole earth
leakage breaker and connect all conductors through the breaker.

Accessories
Optional Factory Installed
Internal Accessories
Earth leakage breakers use the same
internal accessories as standard F-,
J- and K-Frame Series C Breakers.
Internal accessories fit in the righthand pole space and are available as
factory modifications only.
Optional External Accessories
Series C Earth Leakage Breakers use
the same external accessories as the
standard F-, J- and K-Frame circuit
breakers.

113

Time/Current Curves, Dimension Sheets, Application Data

114

Cutler-Hammer

Molded Case Circuit Breakers
Series C Earth Leakage Circuit Breakers

March 1999

Selection Guide and Ordering Information
F-Frame Earth Leakage Ground Fault Breakers UL 489 and UL 1053 – Catalog Numbers
Amperes➂

25 kA at 480 VAC
3-Pole

35
40
45
50
60
70
80
90
100
110
125
150

65 kA at 480 VAC
4-Pole

ELFD4035L
ELFD4040L
ELFD4045L
ELFD4050L
ELFD4060L
ELFD4070L
ELFD4080L
ELFD4090L
ELFD4100L
ELFD4110L
ELFD4125L
ELFD4150L

ELFD3035L
ELFD3040L
ELFD3045L
ELFD3050L
ELFD3060L
ELFD3070L
ELFD3080L
ELFD3090L
ELFD3100L
ELFD3110L
ELFD3125L
ELFD3150L

Continuous Amperes

100 kA at 480 VAC

35 kA at 480 VAC
3-Pole

4-Pole

3-Pole

4-Pole

3

ELHMCP003A0C

ELHFD3035L
ELHFD3040L
ELHFD3045L
ELHFD3050L
ELHFD3060L
ELHFD3070L
ELHFD3080L
ELHFD3090L
ELHFD3100L
ELHFD3110L
ELHFD3125L
ELHFD3150L

ELHFD4035L
ELHFD4040L
ELHFD4045L
ELHFD4050L
ELHFD4060L
ELHFD4070L
ELHFD4080L
ELHFD4090L
ELHFD4100L
ELHFD4110L
ELHFD4125L
ELHFD4150L

ELFDC3035L
ELFDC3040L
ELFDC3045L
ELFDC3050L
ELFDC3060L
ELFDC3070L
ELFDC3080L
ELFDC3090L
ELFDC3100L
ELFDC3110L
ELFDC3125L
ELFDC3150L

ELFDC4035L
ELFDC4040L
ELFDC4045L
ELFDC4050L
ELFDC4060L
ELFDC4070L
ELFDC4080L
ELFDC4090L
ELFDC4100L
ELFDC4110L
ELFDC4125L
ELFDC4150L

7

ELHMCP007C0C

15

ELHMCP015E0C

25

ELHMCP025X0C

30

ELHMCP030H1C

50

ELHMCP050K2C

70

ELHMCP070M2C

100

ELHMCP100R3C

150

ELHMCP150T4C

150

ELHMCP150U4C

100
125
150
175
200
225
250

65 kA at 480 VAC
4-Pole

ELJD4100
ELJD4125
ELJD4150
ELJD4175
ELJD4200
ELJD4225
ELJD4250

ELJD3100
ELJD3125
ELJD3150
ELJD3175
ELJD3200
ELJD3225
ELJD3250

3-Pole

100 kA at 480 VAC
4-Pole

ELHJD3100
ELHJD3125
ELHJD3150
ELHJD3175
ELHJD3200
ELHJD3225
ELHJD3250

3-Pole

4-Pole

ELJDC4100
ELJDC4125
ELJDC4150
ELJDC4175
ELJDC4200
ELJDC4225
ELJDC4250

ELJDC3100
ELJDC3125
ELJDC3150
ELJDC3175
ELJDC3200
ELJDC3225
ELJDC3250

ELHJD4100
ELHJD4125
ELHJD4150
ELHJD4175
ELHJD4200
ELHJD4225
ELHJD4250

K-Frame Earth Leakage Ground Fault Breakers UL 489 and UL 1053 – Catalog Numbers
Amperes

35 kA at 480 VAC
3-Pole

200
225
250
300
350
400

ELKD3200
ELKD3225
ELKD3250
ELKD3300
ELKD3350
ELKD3400

65 kA at 480 VAC
4-Pole

ELKD4200
ELKD4225
ELKD4250
ELKD4300
ELKD4350
ELKD4400

3-Pole

100 kA at 480 VAC
4-Pole

ELHKD3200
ELHKD3225
ELHKD3250
ELHKD3300
ELHKD3350
ELHKD3400

3-Pole

4-Pole

ELKDC3200
ELKDC3225
ELKDC3250
ELKDC3300
ELKDC3350
ELKDC3400

ELHKD4200
ELHKD4225
ELHKD4250
ELHKD4300
ELHKD4350
ELHKD4400

ELKDC4200
ELKDC4225
ELKDC4250
ELKDC4300
ELKDC4350
ELKDC4400

Standard Line and Load Terminals – Included with Breaker
Frame

Wire Type

(Number) Range of Conductors

Terminal Material

F-Frame
F-Frame

35-100A
110-150A

Cu/Al
Cu/Al

(1) #14-1/0
(1) #4-4/0

Steel
Stainless Steel

J-Frame

100-250A

Cu/Al

(1) #4-250 kcmil

Aluminum

K-Frame
K-Frame

200-350A
400A

Cu/Al
Cu/Al

(1) 250-500 kcmil
(2) 3/0-250 kcmil

Aluminum
Aluminum

Optional K-Frame Line and Load Terminals – Order Separately
Wire Type

(Number) Range of Conductors

Catalog Number 3-Pole

3-Pole

J-Frame Earth Leakage Ground Fault Breakers UL 489 and UL 1053 – Catalog Numbers
Amperes

F-Frame HMCP with Earth Leakage Ground Fault

Terminal Material

3

ELHMCP003A0LC

7

ELHMCP007C0LC

15

ELHMCP015E0LC

25

ELHMCP025D0C

30

ELHMCP030H1LC

50

ELHMCP050G2C

70

ELHMCP070J2C

100

ELHMCP100L3C

–

ELHMCP024D0IC

–

ELHMCP050G2IC

–

ELHMCP070J2IC

100

ELHMCP100K3C

HMCPs for Application with Motor Starters
Equipped with Electrical Overload Relays
3

ELHMCPS003A0C

7

ELHMCPS007C0C

15

ELHMCPS015E0C

30

ELHMCPS030H1C

50

ELHMCPS050K2C

100

ELHMCPS100R3C

150

ELHMCPS150T4C

150

ELHMCPS140U4C

J-Frame HMCP with Earth Leakage Ground Fault
Continuous Amperes

ELHMCP250A5
ELHMCP250C5
ELHMCP250D5
ELHMCP250F5
ELHMCP250G5
ELHMCP250J5
ELHMCP250K5
ELHMCP250L5
ELHMCP250W5

400

ELHMCP400D5
ELHMCP400F5
ELHMCP400G5
ELHMCP400J5
ELHMCP400K5

Catalog Number

Cu/Al
Cu/Al

(2) 250 kcmil
(1) 500 kcmil

Aluminum
Aluminum

3TA401K➀

Cu/Al
Cu/Al

(2) 250 kcmil
(1) 500 kcmil

Aluminum
Aluminum

4TA401K➁

Cu

(1) 3-350 kcmil

Copper

T300K

Cu

(1) 3-350 kcmil

Copper

T300K

Cu

(1) 250-500 kcmil

Copper

T350K

Cu

(1) 250-500 kcmil

Copper

T350K

Cu

(1) 3/0-250 kcmil

Copper

3T400K➀

Cu

(1) 3/0-250 kcmil

Copper

3T400K➁

Catalog Number 3-Pole

250

➀ Package of 3 terminals.
➁ Package of 4 terminals.
➂ 15, 20, 25, and 30 ampere available.

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

Cutler-Hammer

Molded Case Circuit Breakers
Non-Fused Current Limiting

March 1999

115

Type FCL Current Limit-R Thermal-Magnetic Circuit Breakers
15 to 100 Amperes, 480 Volts Ac
Non-Interchangeable Trip, Line and
Load Terminals Included

Maximum Continuous
Ampere Rating
@ 40°C

2-Pole➀

3-Pole

Catalog Number

FCL2015L
FCL2020L
FCL2025L
FCL2030L
FCL2035L
FCL2040L
FCL2045L
FCL2050L
FCL2060L
FCL2070L
FCL2080L
FCL2090L
FCL2100L

15
20
25
30
35
40
45
50
60
70
80
90
100

FCL3015L
FCL3020L
FCL3025L
FCL3030L
FCL3035L
FCL3040L
FCL3045L
FCL3050L
FCL3060L
FCL3070L
FCL3080L
FCL3090L
FCL3100L

Line and Load Terminals
Breakers listed include line and load terminals. Terminals are Underwriters
Laboratories, Inc. listed for wire sizes and types listed below. When used with
aluminum cable, use joint compound. To order optional aluminum terminals,
add suffix “Z” to breaker catalog number listed.
Maximum Breaker Amperes

Wire Type

AWG Wire Range

Standard Pressure Terminals
100
Type FCL Breaker

50
100

Dimensions / Weights
Dimensions, Inches
Number of Poles

2-3

Width

Height

4.125
(104.78)

Depth

8.75
(222.25)

3.375
(85.73)

Approximate Shipping Weight, Lbs. (kg)
2-Pole

9
(4.082)

3-Pole

9
(4.082)

Listed with Underwriters Laboratories, Inc. except as noted.
Type FCL breakers are not defined in
Federal Specification W-C-375-b.
Interrupting Capacity Ratings
Circuit
Breaker
Type

Volts Ac
(50/60 Hz)

FCL

240
480

Interrupting Capacity
(Symmetrical Amperes) (kA)

200
150

On all 3-phase Delta, Grounded
B phase applications, refer to
Cutler-Hammer.

➀ 2-pole breakers are supplied in 3-pole frames
with current carrying parts omitted from the
center pole.

PG.74A.01.T.E

Al/Cu

#14-1/0

Al/Cu
Al/Cu

#14-#4
#4-4/0

Optional Al/Cu Pressure Terminals

Time/Current Curves, Dimension Sheets, Application Data

116

Cutler-Hammer

Molded Case Circuit Breakers
Non-Fused Current Limiting

March 1999

Type LCL Current Limit-R Electronic Circuit Breakers
125 to 400 Amperes, 600 Volts Ac
with Solid State Trip Units

Standard Breakers 600 Volts Ac, 50/60 Hz
Complete breaker requires frame, rating plug and terminals
Frame Only
Poles➀

Standard (Long Delay, Magnetic Trip and Current Limiting)

Magnetic Only➁ and
Current Limiting

Long Delay, Magnetic Trip and Adjustable Short
Delay Time (.08-.28 seconds), and Current Limiting

Catalog Number

Types LCL and LCLA 250 Ampere Frame (125-250 Amperes)
2
3

LCL2250F
LCL3250F

LCL2250FM
LCL3250FM

LCLA2250F
LCLA3250F

Type LCL and LCLA 400 Ampere Frame (200-400 Amperes)
2
3

LCL2400F
LCL3400F

LCL2400FM
LCL3400FM

LCLA2400F
LCLA3400F

Instruction Leaflet/FRED Number 15257

Breakers with Built-in Ground Fault Protection
Complete breaker requires frame, rating plug and terminals – extra current
transformer included for neutral.
Frame Only
Poles➀

Standard (Long Delay, Magnetic Trip,
Current Limiting, and Ground Fault Trip)

Long Delay, Magnetic Trip and Adjustable Short Delay Time
(.06-.22 seconds), and Ground Fault Trip and Current Limiting

Catalog Number

Type LCL Breaker

Types LCLG and LCLGA 250 Ampere Frame (125-250 Amperes)

Dimensions / Weights

3

Dimensions, Inches
Number of Poles

2-3

Width

Height

16
(406.40)

Depth

8.25
(209.56)

4.0625
(103.19)

Approximate Shipping Weight, Lbs. (kg)
Standard

2-Pole

32
(14.515)

3-Pole

32
(14.515)

With Ground Fault

3-Pole

LCLG3250F

LCLGA3250F

Types LCLG and LCLGA 400 Ampere Frame (200-400 Amperes)

36
(16.329)

3

LCLG3400F

LCLGA3400F

Instruction Leaflet/FRED Number 15495

Terminals➂ (Order Separately)

Rating Plug Selection Data

Two terminals are required per pole.
Terminals are Underwriters Laboratories, Inc. listed for wire type and
range listed below. When used
with aluminum cable, use joint
compound.

Rating plugs listed below are for
both standard breakers and breakers
with built-in ground fault protection.

Maximum
Breaker
Amperes

Wire Range, Type,
Number of Cables

Terminal
Catalog
Number

Interrupting Capacity Ratings
Circuit
Breaker Type

LCL

Volts Ac
(50/60 Hz)

240
480
600

225
400

200
200
100

On all 3-phase Delta, Grounded
B phase applications, refer to
Cutler-Hammer.

T225LA
T401LA

Optional Al/Cu Pressure Terminals
225

Interrupting Capacity
(Symmetrical Amperes) (kA)

1#6-350 kcmil Cu
1#4-250 kcmil Cu,
plus
1 3/0-600 kcmil Cu

400

1#6-350 kcmil Cu, or
1#4-350 kcmil Al
1#4-250 kcmil Al/Cu,
plus
1 3/0-600 kcmil Al/Cu

Continuous
Ampere
Rating

Magnetic Trip
Fixed
Setting, Amperes Rating
Plugs
Low

High

Adjustable
Rating
Plugs➃

Catalog Number

Types LCL and LCLA 250 Ampere Frames

Standard Copper Pressure Terminals

Listed with Underwriters Laboratories, Inc. except as noted.
Type LCL breakers are not defined in
Federal Specification W-C-375-b.

Rating Plugs Only (For 2- or 3-Pole Frames)

TA225LA1
TA400LA1

➀ 2-pole breakers are supplied in 3-pole frames
with current carrying parts omitted from the
center pole.
➁ UL listed recognized component.
➂ Terminals shipped separately from breaker.

125
150
175
200
225
250

375
450
525
600
675
750

1125
1350
1575
1800
2025
2250

2LCL125
2LCL150
2LCL175
2LCL200
2LCL225
2LCL250

–
–
A2LCL175➄
A2LCL200
A2LCL225
A2LCL250➅

Types LCL and LCLA 400 Ampere Frames
200
225
250
275
300
350
400

400
450
500
550
600
700
800

1600
1800
2000
2200
2400
2800
3200

4LCL200
4LCL225
4LCL250
4LCL275
4LCL300
4LCL350
4LCL400

–
–
–
–
A4LCL300➄
A4LCL350
A4LCL400➅

➃ Adjustable 70 to 100% except as noted.
➄ Adjustable 75 to 100%.
➅ Adjustable 50 to 100%.

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

Cutler-Hammer

Molded Case Circuit Breakers
Fused Current Limiting

March 1999

117

Type FB Tri-Pac Thermal-Magnetic Circuit Breakers
15 to 100 Amperes, 600 Volts Ac,
250 Volts Dc, Replaceable Current
Limiters

Maximum Continuous
Ampere Rating
@ 40°C

2-Pole➀

3-Pole

Catalog Number (Current Limiters Included)

FB3015PL
FB3020PL
FB3030PL
FB3040PL
FB3050PL
FB3060PL
FB3070PL
FB3090PL
FB3100PL

FB2015PL
FB2020PL
FB2030PL
FB2040PL
FB2050PL
FB2060PL
FB2070PL
FB2090PL
FB2100PL

15
20
30
40
50
60
70
90
100

Line and Load Terminals
Breakers listed include line and load terminals. Terminals are Underwriters
Laboratories, Inc. listed for wire sizes and types listed below. When used with
aluminum cable, use joint compound. To order optional aluminum terminals,
add suffix “Z” to breaker catalog number listed.
Maximum Breaker Amperes

Wire Type

AWG Wire Range

Standard Pressure Terminals
100
50
100

Dimensions / Weights
Dimensions, Inches
Number of Poles

2-3

4.125
(104.78)

Height

8.75
(222.25)

Depth

3.5
(88.90)

#14-#4
#4-4/0

Current Limiters: One required per pole.
Application

Catalog Number

Supplied as standard in Type FB Tri-Pac breakers rated 15-100 amperes.
Replaces 200FBP03 formerly supplied on 15-40 ampere ratings, and
500FBP07 formerly supplied on 50-100 ampere ratings.

100FBP06

Refer to CAT.71.01.T.E for complete application information.

3-Pole

10.5

11.5

Listed with Underwriters Laboratories, Inc. except as noted.
Tri-Pac FB breakers meet the
requirements for Class 16a, 16b, 17a
and 26a circuit breakers as defined
in Federal Specification W-C-375b.
Interrupting Capacity Ratings
Underwriters Laboratories, Inc.
Listed
600 Volts Ac Maximum: 200,000
Amperes Symmetrical
Based on NEMA Test Procedures
250 Volts Dc Maximum: 100,000
Amperes.
On all 3-phase Delta, Ground B phase
applications, refer to Cutler-Hammer.
➀ 2-pole breakers are supplied in 3-pole frames
with current carrying parts omitted from the
center pole.

PG.74A.01.T.E

Al/Cu
Al/Cu

Complete Breaker
2-Pole

Tri-Pac FB

#14-1/0

Replacement Current Limiters and Housing Assembly

Width

Approximate Shipping Weight, Lbs. (kg)
Breaker

Al/Cu

Optional Al/Cu Pressure Terminals

Type Tri-Pac FB Breaker

Current Limiter Housing Assembly Complete with Current Limiter
Ampere Rating

Poles

15-100
15-100

Style Number

2
3

176C593G09
176C593G10

Time/Current Curves, Dimension Sheets, Application Data

118

Cutler-Hammer

Molded Case Circuit Breakers
Fused Current Limiting

March 1999

Type LA Tri-Pac Thermal-Magnetic Circuit Breakers
70 to 400 Amperes, 600 Volts Ac,
250 Volts Dc, 2-, 3-Pole, Interchangeable Trip, Replaceable
Current Limiters

Continuous
Ampere
Rating
@40°C

Magnetic Trip Setting
Amperes➃

Complete Breaker

Shipped as Frame, Trip Units, Limiters and Terminals➄

Includes Pressure Type
Copper Terminals➄

Frame Only

Low

Catalog Number

High

Trip Unit Only

Current Limiter
1 Required per
Pole

2 Poles, 600 Volts Ac, 250 Volts Dc➅
70
90
100
125
150
175
200
225
250
300
350
400

350
450
500
625
750
875
1000
1125
1250
1500
1750
2000

700
900
1000
1250
1500
1750
2000
2250
2500
3000
3500
4000

LA2070PR
LA2090PR
LA2100PR
LA2125PR
LA2150PR
LA2175PR
LA2200PR
LA2225PR
LA2250PR
LA2300PR
LA2350PR
LA2400PR

LA2400PRF
LA2400PRF
LA2400PRF
LA2400PRF
LA2400PRF
LA2400PRF
LA2400PRF
LA2400PRF
LA2400PRF
LA2400PRF
LA2400PRF
LA2400PRF

LA2070PT
LA2090PT
LA2100PT
LA2125PT
LA2150PT
LA2175PT
LA2200PT
LA2225PT
LA2250PT
LA2300PT
LA2350PT
LA2400PT

200LAP08
200LAP08
200LAP08
200LAP08
200LAP08
200LAP08
200LAP08
400LAP10
400LAP10
400LAP10
400LAP10
400LAP10

LA3070PR
LA3090PR
LA3100PR
LA3125PR
LA3150PR
LA3175PR
LA3200PR
LA3225PR
LA3250PR
LA3300PR
LA3350PR
LA3400PR

LA3400PRF
LA3400PRF
LA3400PRF
LA3400PRF
LA3400PRF
LA3400PRF
LA3400PRF
LA3400PRF
LA3400PRF
LA3400PRF
LA3400PRF
LA3400PRF

LA3070PT
LA3090PT
LA3100PT
LA3125PT
LA3150PT
LA3175PT
LA3200PT
LA3225PT
LA3250PT
LA3300PT
LA3350PT
LA3400PT

200LAP08
200LAP08
200LAP08
200LAP08
200LAP08
200LAP08
200LAP08
400LAP10
400LAP10
400LAP10
400LAP10
400LAP10

3 Poles, 600 Volts Ac, 250 Volts Dc
70
90
100
125
150
175
200
225
250
300
350
400

Type Tri-Pac LA Breaker

Dimensions / Weights
Dimensions, Inches
Number of Poles

2-3

Width

Height

8.25
(209.56)

16
(406.40)

700
900
1000
1250
1500
1750
2000
2250
2500
3000
3500
4000

Instruction Leaflet/FRED Number 14551 for Trip Unit and Fuse

Depth

4.75
(113.54)

Approximate Shipping Weight, Lbs. (kg)
Breaker

350
450
500
625
750
875
1000
1125
1250
1500
1750
2000

Complete
Breaker

Frame
Only

Trip
Unit

2Pole

3Pole

2Pole

3Pole

2Pole

3Pole

Tri-Pac LA 29.75

34

23.5

25

2.25

3

Listed with Underwriters Laboratories, Inc. except as noted.
Tri-Pac LA breakers meet the
requirements for Class 16a, 16b, 17a
and 26a circuit breakers as defined in
Federal Specification W-C-375b.
Interrupting Capacity Ratings
Underwriters Laboratories, Inc.
Listed
600 Volts Ac Maximum: 200,000
Amperes Symmetrical
Based on NEMA Test Procedures
250 Volts Dc Maximum: 100,000
Amperes.
On all 3-phase Delta, Ground B phase
applications, refer to Cutler-Hammer.

Current Limiters

Terminals➄

Included with breaker, one required
per pole.

Two terminals are required per pole.
Terminals are Underwriters Laboratories, Inc. listed for wire size and
type listed below. When used with
aluminum conductors, use joint
compound. To order optional aluminum terminals, add suffix “Z” to
complete breaker catalog number.

Application

Catalog
Number

Supplied as standard on ratings
through 200 amperes.

200LAP08

Supplied as standard on 225 through
400 ampere ratings, optional on lower
ratings when a higher “cross-over
point” is desired. (Above two limiters
replace 800LAP12 formerly supplied
as standard on all ratings, 600LAP09
optional on all ratings through 300
amperes, 300LAP05 optional on ratings through 150 amperes, and special rating limiter 1000LAP14.)

400LAP10

Special rating where a higher “crossover point” is desired on 200 ampere
and higher ratings (Replaces limiter
1500LAP20)

500LAP15
➁➂

Maximum
Breaker
Amperes

Wire Range, Type,
Number of Cables

Terminal
Catalog
Number

Standard Copper Pressure Terminals
225
225➆
400

Optional Al/Cu Pressure Terminals
225
400

➀ New limiters suitable for replacement in
existing breakers by using plug-in conductor
from old limiter (instructions included with
limiter). Instruction Leaflet/FRED Number
14824
➁ Not listed with Underwriters Laboratories, Inc.
➂ Protection based on 100,000 ampere maximum fault, 480 volts maximum.
➃ Set on high side, adjustable to lower limits.

T225LA
T225LBF
T401LA

1 #6-350 kcmil Cu
1 #6-250 kcmil Cu
1 #4-250 kcmil Cu, plus
1 3/0-600 kcmil Cu
1 #6-350 kcmil Cu, or
1 #4-350 kcmil Cu/Al
1 #4-250 kcmil Al/Cu, plus
1 3/0-600 kcmil Al/Cu

TA225LA1
TA400LA1

Instruction Leaflet/FRED Number 13732

➄ Terminals shipped separately from breakers.
➅ 2-pole breakers or trips are supplied in 3-pole
frames with current carrying parts omitted
from the center pole.
➆ Optional terminal.

PG.74A.01.T.E

Time/Current Curves, Dimension Sheets, Application Data

Cutler-Hammer

Molded Case Circuit Breakers
Fused Current Limiting

March 1999

119

Type NB Tri-Pac Thermal-Magnetic Circuit Breakers
300 to 800 Amperes, 600 Volts Ac,
250 Volts Dc➀, 2-, 3-Pole, Interchangeable Trip, Replaceable
Current Limiters

Continuous
Ampere
Rating
@40°C

Magnetic Trip Setting
Amperes➃

Complete Breaker

Shipped as Frame, Trip Units, Limiters and Terminals

Includes Pressure Type
Copper Terminals➄

Frame Only

Low

Catalog Number

High

Trip Unit Only

Current Limiter
1 Required per Pole

2 Poles, 600 Volts Ac, 250 Volts Dc➀➂
300
350
400➃
500➃
600➃
700➃
800➃

1500
1750
2000
2500
3000
3000
3000

3000
3500
4000
5000
6000
6000
6000

NB2300P
NB2350P
NB2400P
NB2500P
NB2600P
NB2700P
NB2800P

NB2800PF
NB2800PF
NB2800PF
NB2800PF
NB2800PF
NB2800PF
NB2800PF

NB2300PT
NB2350PT
NB2400PT
NB2500PT
NB2600PT
NB2700PT
NB2800PT

500NBP12
500NBP12
500NBP12
500NBP12
800NBP20
800NBP20
800NBP20

NB3300P
NB3350P
NB3400P
NB3500P
NB3600P
NB3700P
NB3800P

NB3800PF
NB3800PF
NB3800PF
NB3800PF
NB3800PF
NB3800PF
NB3800PF

NB3300PT
NB3350PT
NB3400PT
NB3500PT
NB3600PT
NB3700PT
NB3800PT

500NBP12
500NBP12
500NBP12
500NBP12
800NBP20
800NBP20
800NBP20

3 Poles, 600 Volts Ac Only
300
350
400➃
500➃
600➃
700➃
800➃

1500
1750
2000
2500
3000
3000
3000

3000
3500
4000
5000
6000
6000
6000

Instruction Leaflet/FRED Number 13771 for Trip Unit and Fuse

Interrupting Capacity Ratings
Underwriters Laboratories, Inc.
Listed
600 Volts Ac Maximum: 200,000
Amperes Symmetrical
Based on NEMA Test Procedures
250 Volts Dc Maximum➀: 100,000
Amperes.

Type Tri-Pac NB Breaker

Dimensions / Weights
Dimensions, Inches
Number of Poles

2-3

Width

Height

8.25
(209.56)

22
(558.80)

On all 3-phase Delta, Grounded
B phase applications, refer to
Cutler-Hammer.

Depth

5.5
(139.70)

Included with breaker, one required
per pole.

Approximate Shipping Weight, Lbs. (kg)
Breaker

Complete
Breaker

Frame
Only

2Pole

3Pole

2Pole

3Pole

2Pole

3Pole

62

75

58

65

3.5

4

Tri-Pac NB

Trip
Unit

Listed with Underwriters Laboratories, Inc. except as noted.
Tri-Pac NB breakers meet the
requirements for Class 16b, 17a and
26a circuit breakers as defined in
Federal Specification W-C-375b.

➀ Dc rating applies to 350 amperes maximum
thermal or to magnetic only breakers.
➁ Shipped separately from breaker
➂ 2-pole breakers or trips are supplied in 3-pole
frames with current carrying parts omitted
from the center pole.
➃ 60 Hz Ac only.

PG.74A.01.T.E

Current Limiters

Application

Catalog
Number

Supplied as standard on ratings
through 500 amperes.

500NBP12

Supplied as standard on 600 through
800 ampere ratings, optional on
lower ratings when a higher “crossover point” is desired.

800NBP20

Above two limiters replace
1000NBP14 formerly supplied on ratings up to 600 amperes, 1500NBP20
supplied on 700 amperes, and
2500NBP25 supplied on 800 amperes.

Terminals➁
Two terminals are required per pole.
Terminals are Underwriters Laboratories, Inc. listed for wire size and
type listed below. When used with
aluminum conductors, use joint
compound. To order optional aluminum terminals, add suffix “Z” to
complete breaker catalog number.
Maximum
Ampere
Rating

Wire Range, Type,
Number of Cables

Terminal
Catalog
Number

Standard Copper Pressure Terminals
350
700
800

1 #1-600 kcmil Cu
2 2/0-500 kcmil Cu
3 3/0-500 kcmil Cu

T350NB
T700NB1
T1000NB1

Optional Al/Cu Pressure Terminals
700
800
800

2 #1-500 kcmil Al/Cu
3 3/0-400 kcmil Al/Cu
3 500-750 kcmil Al/Cu

TA700NB1
TA1000NB1
TA1201NB1

Time/Current Curves, Dimension Sheets, Application Data

120

Cutler-Hammer

Molded Case Circuit Breakers
Fused Current Limiting

March 1999

Type PB Tri-Pac Thermal-Magnetic Circuit Breakers
600 to 1600 Amperes, 600 Volts Ac,
60 Hertz Ac➀, 250 Volts Dc➁,
2-, 3- Poles Interchangeable Trip,
Replaceable Current Limiters

Continuous
Ampere
Rating
@40°C

Ac Magnetic Trip Setting (Set on High Side,
Adjustable to Lower
Limits)

Complete Breaker

Shipped as Frame, Trip Unit Current Limiters and Connectors

Includes Rear
“T” Connectors➄

Frame Only

Low

Catalog Number

High

Trip Unit Only➃

Current Limiter
1 Required per Pole

2 Poles, 600 Volts Ac➄
600
700
800
900
1000
1200
1400
1600

1500
1500
1500
1500
1500
2000
2500
3000

5000
5000
5000
5000
5000
6000
7000
8000

PB2600PR
PB2700PR
PB2800PR
PB2900PR
PB21000PR
PB21200PR
PB21400PR
PB21600PR

PB21600PRF
PB21600PRF
PB21600PRF
PB21600PRF
PB21600PRF
PB21600PRF
PB21600PRF
PB21600PRF

PB2600PRT
PB2700PRT
PB2800PRT
PB2900PRT
PB21000PRT
PB21200PRT
PB21400PRT
PB21600PRT

1000PBPR20
1000PBPR20
1000PBPR20
1000PBPR20
1000PBPR20
1600PBPR30
1600PBPR30
1600PBPR30

PB3600PR
PB3700PR
PB3800PR
PB3900PR
PB31000PR
PB31200PR
PB31400PR
PB31600PR

PB31600PRF
PB31600PRF
PB31600PRF
PB31600PRF
PB31600PRF
PB31600PRF
PB31600PRF
PB31600PRF

PB3600PRT
PB3700PRT
PB3800PRT
PB3900PRT
PB31000PRT
PB31200PRT
PB31400PRT
PB31600PRT

1000PBPR20
1000PBPR20
1000PBPR20
1000PBPR20
1000PBPR20
1600PBPR30
1600PBPR30
1600PBPR30

3 Poles, 600 Volts Ac Only
600
700
800
900
1000
1200
1400
1600
Type Tri-Pac PB Breaker

Dimensions / Weights
Dimensions, Inches
Number of Poles

2-3

Width

Height

12.0625
(306.39)

22.125
(561.98)

Tri-Pac PB

5000
5000
5000
5000
5000
6000
7000
8000

Current Limiters

Bus Bar Connectors➅

Included with breaker, one required
per pole.

“T” Connector for
Cu/Al Bus
Two required per pole.
For rear bus connection.
Accepts up to four bus
bolts. May be rotated 90º.

Application

Catalog
Number

Supplied as standard on ratings
through 1000 amperes. (Replaces
limiter 1500PBPR30 formerly supplied on 600 and 700 ampere ratings, and 3000 PBPR27 supplied on
800-1000 ampere ratings.

1000PBPR20

Supplied as standard on 1200
through 1600 ampere ratings.
Optional on lower ratings where a
higher “cross-over point” is
desired. (Replaces limiter
4000PBR30 formerly supplied on
1200 through 1400 ampere ratings,
and 5000PBPR42 supplied on 1600
ampere ratings.

1600PBPR30

Depth

9.0625
(230.19)

Approximate Shipping Weight, Lbs. (kg)
Breaker

1500
1500
1500
1500
1500
2000
2500
3000

Complete
Breaker

Frame
Only

Trip
Unit

2Pole

3Pole

2Pole

3Pole

2Pole

3Pole

148

179

106

120

18

23

Listed with Underwriters Laboratories, Inc. except as noted.
Tri-Pac PB breakers meet the
requirements for Class 17a and 26a
circuit breakers as defined in Federal
Specification W-C-375b.

Catalog Number

BA2000B

Cable Connector
(Optional)
For “T” connector.
Accepts four 600 kcmil
copper cables.
Style Number

505C706G04

Special Breakers➅
Magnetic Only Type Tri-Pacs:
Available on request.

Interrupting Capacity Ratings
Underwriters Laboratories, Inc.
Listed
600 Volts Ac Maximum: 200,000
Amperes Symmetrical
Based on NEMA Test Procedures
250 Volts Dc➁: 100,000 Amperes.
On all 3-phase Delta, Grounded
B phase applications, refer to
Cutler-Hammer.

➀ Higher frequency calibration not available.
Minimum of 50 Hz calibration available on
special order.
➁ 250 volts Dc rating applies only to magnetic
only breakers.
➂ Shipped separately from breaker.

➃ Magnetic only trip units are available. Order
by description.
➄ 2-pole breakers are supplied in 3-pole frames
with current carrying parts omitted from
center pole.
➅ Not listed with Underwriters
Laboratories, Inc.

PG.74A.01.T.E

Cutler-Hammer

Molded Case Circuit Breakers
Accessories for Current Limiting Circuit Breakers

March 1999

Alarm Switch

Auxiliary Switch➁

For light or alarm indication when
breaker trips. Does not function with
manual operation. Automatically
resets when breaker is relatched.
Standard leads extend 18 inches outside of breaker. Longer leads may be
specified. Not field mountable.

For auxiliary control circuits. Miniature switches mount within breaker.
Commonly used for remote indication of open or closed breaker and
electrically interlocking component
control circuits. “A” contacts are
closed when breaker is closed. “B”
contacts are open when breaker is
closed. Standard leads extend 18
inches outside of breaker. Longer
leads may be specified.

Breaker
Frame

FCL
LA Tri-Pac
NB Tri-Pac
PB Tri-Pac
LCL

Normal
Pole Meeting

Contact Operation
(Specific Type Desired)

Center
Left
Left
Left
Left➀

Make or Break
Make or Break
Make or Break
Make or Break
Make or Break

Alarm Switch Contact Rating (Non
Inductive) LA Tri-Pac: 10 amperes,
120 volt Ac; 5A, 240 volt Ac.

Auxiliary Switch Attachment Kits for Field Mounting➂➃
Breaker
Type

For Right-Hand Mounting

For Left-Hand Mounting

1A-1B

1A-1B

2A-2B

2A-2B

Maxmum
Ac Voltage
Rating➄

Style Number

FCL
NB Tri-Pac
PB Tri-Pac
LCL

1369D79G03
4980D16G05
2602D32G14
–

–
4980D16G06
2602D32G15
–

1369D79G03
4980D16G12
2602D32G11
1372D49G03

–
4980D16G13
2602D32G12
1372D49G06

240
480
480
480

Instruction Leaflet/FRED Number 14535 NB Tri-Pac; 14534 PB Tri-Pac; 15279 LCL

Factory Mounted
Auxiliary Switches➁
All of the above auxiliary switches
can be specified for factory mounting at the same price as listed for the
kit. These attachments have the
leads out the side of the breaker and
are UL listed when factory mounted
unless other non UL listed modifications are used (except as noted).
Factory mounted switches only can
be supplied for the following breakers: FB Tri-Pac➅, LA Tri-Pac. Order
by description.

➀ When alarm switch is used in conjunction
with auxiliary switch, the auxiliary switch is
rated 250 volts max., 5 amperes maximum.
➁ Left-hand mounting is standard unless otherwise specified.
➂ All switches are multiples of 1A-1B with a
common electrical connection (See diagram
above).
➃ Field mounting voids UL listing of breaker
except on NB Tri-Pac and PB Tri-Pac breakers.
➄ For Dc applications refer to factory.
➅ Right-hand mounting only.

PG.74A.01.T.E

Maximum
Non-Inductive
Amperes

Red Lead

Black Lead
Blue Lead

5
10
10
6 (10@240)

121

122

Cutler-Hammer

Molded Case Circuit Breakers
Accessories for Current Limiting Circuit Breakers
Shunt Trip

March 1999

Shunt Trip for Field Mounting➀➁➂
Voltage/Hz

Breaker Type
Right-Hand Mounting
FCL

Left-Hand Mounting

NB Tri-Pac

PB Tri-Pac

FCL

NB Tri-Pac

PB Tri-Pac

Style Number

For tripping breaker from a remote
point. A solenoid device mounts
within breaker case. Breaker trips
when coil is energized.
Shunt trips should not be used as
circuit interlocks using maintained
contact pilot devices.
A cutoff switch breaks the circuit to
the momentary rated coil when
breaker opens. Available for control
voltages up to 250 volts Dc or 600
volts Ac. Voltage and frequency
must be specified. Standard leads
extend 18 inches outside of breaker.
Longer leads may be specified.

600/50-60 Hz
480/50-60 Hz
240/50-60 Hz
208/50-60 Hz
120/50-60 Hz
60/50-60 Hz
48/50-60 Hz
24/50-60 Hz
250 Dc
125 Dc
60 Dc
48 Dc
24 Dc
12 Dc

1369D80G15
1369D80G16
1369D80G17
1369D80G18
1369D80G19
1369D80G20
1369D80G21
1369D80G22
1369D80G23
1369D80G24
1369D80G25
1369D80G26
1369D80G27
1369D80G28

2606D58G15
2606D58G16
2606D58G17
2606D58G18
2606D58G19
2606D58G20
2606D58G21
2606D58G22
2606D58G23
2606D58G24
2606D58G25
2606D58G26
2606D58G27
2606D58G28

2606D58G15
2606D58G16
2606D58G17
2606D58G18
2606D58G19
2606D58G20
2606D58G21
2606D58G22
2606D58G23
2606D58G24
2606D58G25
2606D58G26
2606D58G27
2606D58G28

1369D80G01
1369D80G02
1369D80G03
1369D80G04
1369D80G05
1369D80G06
1369D80G07
1369D80G08
1369D80G09
1369D80G10
1369D80G11
1369D80G12
1369D80G13
1369D80G14

2606D58G01
2606D58G02
2606D58G03
2606D58G04
2606D58G05
2606D58G06
2606D58G07
2606D58G08
2606D58G09
2606D58G10
2606D58G11
2606D58G12
2606D58G13
2606D58G14

2606D58G01
2606D58G02
2606D58G03
2606D58G04
2606D58G05
2606D58G06
2606D58G07
2606D58G08
2606D58G09
2606D58G10
2606D58G11
2606D58G12
2606D58G13
2606D58G14

14940

15194

14919

14940

Instruction Leaflet/FRED Numbers
15194
14919

Factory mounted shunt trips only can be supplied for FB Tri-Pac➃➄ and
LA Tri-Pac breakers. Order by description.
Left-Hand Mounting Kits for Type LCL
Current Limiting Breakers➅
Provision to trip flux transfer shunt
trip from external 32 to 120 volt
(Dc to 60 Hz) source.➆➇

Style
Number

Provision to trip flux transfer shunt
trip from external 240 to 600 volt
(50/60 Hz) source.➇➈

1372D49G32

1372D49G22

Shunt Trip Coil Data for Type LCL
Current Limiting Breakers
Shunt Trip
Voltage
Rating

120 Ac

Coil Inrush
Amperes

.15

Volt-Amperes

18

Instruction Leaflet/FRED Number 15279

➀ 120 volt Ac ratings suitable for 55% pickup
for ground fault applications.
➁ Not field mountable on non-automatic
breakers (MCS).
➂ Field mounting voids breakers’ UL listing
except on NB Tri-Pac and PB Tri-Pac.
➃ Right-hand mounting only.
➄ Not UL listed.
➅ UL listing pending. Refer to Cutler-Hammer.
➆ Rated 48 volts minimum for ground fault
applications.
➇ Also available factory mounted for 24 volt
Dc. Order by description.
➈ Not for ground fault.

PG.74A.01.T.E

Cutler-Hammer
March 1999

Standard Undervoltage
Release➀

Molded Case Circuit Breakers
Accessories for Current Limiting Circuit Breakers

123

Undervoltage Release Attachment Kits for Field Mounting➄➅
Attachment
Voltage, Hz

Breaker Type
For Right-Hand Mounting
NB Tri-Pac

For Left-Hand Mounting
PB Tri-Pac

NB Tri-Pac

PB Tri-Pac

Style Number

For undervoltage protection. A solenoid device mounts within breaker
case. Coil must be energized before
closing breaker. Trips breaker when
voltage drops below 40 to 60% of
coil rating. Picks up and seals in at
80% of coil rating. For line voltages
up to 250 volts Dc or 600 volts Ac.
Externally mounted resistors are
supplied for certain ratings. Standard leads extend 18 inches outside
of breaker. Longer leads may be
specified.
Note: U.V.R. attachments are not
designed for, and should not be used
as, circuit interlocks. For further
information, refer to Cutler-Hammer.
Factory Mounted
Undervoltage Releases➁
NB Tri-Pac and PB Tri-Pac undervoltage releases can be specified for
factory mounting at the same price
as the kit. These attachments have
the leads out the side and are
UL listed when factory mounted
unless other non-UL listed modifications are used.
Factory mounted undervoltage
releases only can be supplied for the
following breakers: FB Tri-Pac➂,
LA Tri-Pac and FCL; LCL 120 Volts
Ac only.➃ Order by description.

➀ Not UL listed.
➁ Right-hand mounting considered standard
unless specified otherwise.
➂ Right-hand mounting only.
➃ UL listing pending.
➄ Not field mountable on nonautomatic
breakers (Molded case switches).
➅ Field mounting voids UL listing of breaker
except on NB Tri-Pac and PB Tri-Pac.

PG.74A.01.T.E

24 60
48 60
120 60
208 60
240 60
480 60
600 60
12 Dc
24 Dc
48 Dc
60 Dc
125 Dc
250 Dc

Instruction Leaflet/FRED Number
14961

–
5674D29G08
5674D29G01
5674D29G02
5674D29G03
5674D29G05
5674D29G06
4976D85G11
4976D85G12
4976D85G13
4976D85G14
4976D85G17
4976D85G18

–
–
373D632G05
373D632G20
373D632G06
373D632G07
373D632G08
372D032G06
372D032G07
372D032G08
–
372D032G09
372D032G10

–
5674D29G16
5674D29G09
5674D29G10
5674D29G11
5674D29G13
5674D29G14
4976D85G01
4976D85G02
4976D85G03
4976D85G04
4976D85G07
4976D85G08

–
–
373D632G01
373D632G19
373D632G02
373D632G03
373D632G04
372D032G01
372D032G02
372D032G03
–
372D032G04
372D032G05

13231

14961

13231

Undervoltage Release Coil Data
Voltage
Rating, Hz

Breaker Type
FB Tri-Pac
Coil Amperes

600 Ac
480 Ac
240 Ac
208 Ac
120 Ac
60 Ac
48 Ac
24 Ac
250 Ac
125 Ac
60 Ac
48 Ac
24 Ac
12 Ac
Voltage
Rating, Hz

Total VA

Coil Amperes

Total VA

–
–
–
–
6
–
–
–
–
–
–
–
–
–

–
–
–
–
.05
–
–
–
–
–
–
–
–
–

12.0
7.7
5.1
4.0
2.8
12.2
11.8
6.0
6.5
3.3
14.9
12.5
3.4
3.5

25,000
25,000
6,000
6,000
–
250
150
50
5,000
–
200
150
–
–

0.020
0.016
0.021
0.019
0.023
0.203
0.245
0.250
0.026
0.026
0.248
0.260
0.141
0.286
Breaker Type
LA Tri-Pac, PB Tri-Pac
Coil
Amperes

600 Ac
480 Ac
240 Ac
208 Ac
120 Ac
48 Ac
250 Dc
125 Dc
60 Dc
48 Dc
24 Dc
12 Dc

LCL
Series Resistance
(Ohms)

0.029
0.014
0.036
0.036
0.073
0.152
0.035
0.039
0.034
0.040
0.069
0.136

External Series
Resistance
(Ohms)

20,000
–
–
–
–
–
5,000
1,500
–
–
–
–

NB Tri-Pac
Total
VA

Coil
Amperes

17.4
6.8
8.7
7.5
8.8
7.3
8.8
4.9
2.1
2.0
1.7
1.7

0.016
0.013
0.013
0.018
0.023
–
0.013
0.013
–
0.012
0.023
0.048

External Series
Resistance
(Ohms)

35,000
30,000
–
–
–
–
16,500
6,500
–
600
–
–

Total
VA

9.6
6.3
3.2
3.8
2.8
–
3.3
1.7
–
0.6
0.6
0.6

124

Cutler-Hammer

Molded Case Circuit Breaker
Accessories for Current Limiting Circuit Breakers

Rear Connected Studs➀

Mounting Panel
Thickness, Inches

March 1999

Stud

Tube➂

Length

Style Number

Length

Style Number

FCL and FB Tri-Pac Breakers
Short
Long
Short
Long
Short
Long
Short
Long

1
⁄16 - 15⁄16

11

⁄8 - 5⁄8

3

⁄4 - 5⁄16

1

For complete stud assembly, order a
stud and appropriate tube based on
thickness of customer’s mounting
panel. A short stud must be assembled adjacent to a long stud to
maintain clearances required by
Underwriters Laboratories, Inc.➁
Two studs are required per pole.

Panelboard Connecting
Staps➀
For connecting line end of breakers
to panelboard bus.

Stud Ampere Rating

Diameter, Inches
and Thread

11⁄16
37⁄16
13⁄8
33⁄4
111⁄16
41⁄16
2
43⁄8

451D874G01
451D874G02
451D874G01
451D874G02
451D874G01
451D874G02
451D874G01
451D874G02
Extension Back of
Breaker, Inches

32B9446H20
32B9446H24
32B9446H21
32B9446H25
32B9446H22
32B9446H26
32B9446H23
32B9446H27

Stud Style Number

LCL, LA Tri-Pac Breakers
400➃
400➃
400➃

3

⁄ -16
⁄ -16
3⁄ -16
4

515⁄32
731⁄32
1015⁄32

05B7383G15
05B7383G16
05B7383G17

11⁄8 -12
11⁄8 -12
11⁄8 -12
11⁄4 -12
11⁄4 -12

51⁄2
8
101⁄2
51⁄2
101⁄2

623B222G01
623B222G02
623B222G03
623B375G04
623B375G03

4
34

NB Tri-Pac Breakers
450
450
450
800
800

Plug-in Adapter Kits
Description

Style Number

FB Tri-Pac and FCL Breakers➄
1 Mounting Block, Line or Load
2-Pole, 100 Ampere
2-Pole, 150 Ampere
3-Pole, 100 Ampere
3-Pole, 150 Ampere
Ampere Rating

Connector Type

Instruction Leaflet/FRED Number 13782

Style Number

LCL Breakers

Power Panelboards (Convertible)
Tri-Pac FB and FCL Breakers Bus Spacing 31⁄2-inch
50
50
100
100
150
150

Center
Outside
Center
Outside
Center
Outside

3-Pole Mounting Bracket
2-Pole Mounting Bracket

1253C72G01
1253C72G02
1253C73G03
1253C73G04
1253C73G01
1253C73G02
624B600H01
624B600H02

LCL Breakers Bus Spacing 31⁄2-inch
400
400
400

Short
Medium
Long

Mtg. Bracket Kit (1 Req’d)

1275C85G01
1275C85G02
1275C85G03
751B044G01

507C036G05
507C036G06
507C036G03
507C036G04

2 Mounting Blocks, Line and Load

For rear connected applications such
as switchboards. Facilitates ease of
installation and front removal of
breaker. Includes conductor for
mounting on breaker, plug-in
mounting blocks with matching conductor, rear studs and mounting
hardware. Order two mounting
blocks style number when line and
load are required; order one mounting block style number when either
line or load is required.

2-Pole
3-Pole

313C644G25
313C644G26

1 Mounting Block, Line and Load
2-Pole
3-Pole

450D010G15
450D010G16

Instruction Leaflet/FRED Number 15329

NB Tri-Pac Breakers➀
1 Mounting Block, Line or Load
NB Tri-Pac, 2 Poles
NB Tri-Pac, 3 Poles

2614D53G03
2614D53G04

Instruction Leaflet/FRED Number 15073

Tri-Pac LA Breakers➀
2 Mounting Blocks, Line and Load
2-Pole
3-Pole
➀ Not Underwriters Laboratories, Inc. listed.
➁ 400 ampere LA studs of the same length
have sufficient clearance; however, customer connections may make it necessary
to use a short stud adjacent to a long stud.
➂ Included at no charge when ordered with
stud.
➃ 150, 250, 300 and 400 ampere frames only.
➄ These plug-in adapter kits are UL listed as
recognized components.

313C644G41
313C644G42

1 Mounting Block, Line Only
2-Pole
3-Pole

450D010G17
450D010G19

1 Mounting Block, Load Only
2-Pole
3-Pole

450D010G18
450D010G20

PG.74A.01.T.E

Cutler-Hammer

Molded Case Circuit Breakers
Accessories for Current Limiting Circuit Breakers

March 1999

Mounting Block for
NB Tri-Pac Breakers➀
Ampere Rating

Number of Poles

Handle Locks➀

Kirk Key Interlock➄

Style Number

NB Tri-Pac
800
800

2
3

4990D16G04
4990D16G03

Availability: FB, LA, NB, PB Tri-Pacs.

Extended Line Terminal
Shields➀
Non-Padlockable
For prevention of unintentional
operation of breaker. Fits over
breaker handle and may be
removed.

For shielding line side terminal connections. One shield required per
breaker. Order separately when
needed. Sold only in lots of 10,
including hardware.
Breaker Frame

FB Tri-Pac, FCL
LA Tri-Pac
NB Tri-Pac

Style Number

625B229G01
314C420G05
208B996G02

Padlockable
For prevention of unauthorized
operation of breaker. Is nonremovable once installed on
breaker. Meets Underwriters
Laboratories, Inc. and California
Code requirements.

Breaker Frame

FB Tri-Pac, FCL
LA Tri-Pac
NB Tri-Pac
PB Tri-Pac

Breaker Frame

Style Number

Non-Padlockable
29B2721H01
1720101
1720101

FB Tri-Pac
LA Tri-Pac
NB Tri-Pac
Padlockable
FB Tri-Pac
LA Tri-Pac

Style Number

21C6782G18
1614613
1091716
624375G22

765A754G01
373B591G02

Handle Extension
Breaker Frame

LA Tri-Pac
NB Tri-Pac
PB Tri-Pac➁

Moisture-Fungus-Corrosion
Treatment➁

Style Number

372B399G01
1251C65G01
315C882G01

Treatment can be provided to meet
customer’s specific atmospheric
conditions. Moisture-fungus treating material used meets JAN-T-152;
treatment meets MIL-V-173a.
Requests and orders should specify
government specifications or conditions to be met.

➀ Not Underwriters Laboratories, Inc. listed.
Insulated base with front removeable bolted
connection.
➁ Included with frame

PG.74A.01.T.E

Mechanical Interlocks➁

Note: All breakers are trip free and
will trip with handle locks attached.
Cannot be used when handle extension is used.

Base Mounting Hardware
Order separately when needed.

Permits interlocking of two breakers
or one breaker with other devices.
Before breaker can be closed, key
must be inserted and turned in
breaker interlock. Breaker must be
opened before key can be removed.
It can then be inserted in interlock or
other devices to permit their closure.
Requests and orders should completely outline interlocking scheme,
ultimate user and his address.

For mechanically interlocking a pair
of breakers so that only one may be
closed at one time, but both may be
open simultaneously.
Walking Beam Type➁➂➃
Mounts on panel (not included) at
rear of breaker. Standard breaker
spacing: LA Tri-Pac, NB Tri-Pac: 8-1/2
inches center to center; FB Tri-Pac:
4-3/8 inches center to center; PB TriPac: 12-1/4 inches center to center.
Order as a set of two special factory
drilled breakers and one walking
beam interlock. Specify breaker
type, panel thickness and center-tocenter dimension of breakers.
Sliding Bar Type (Field Mountable)➁➄

➂
➃
➄
➅

Not UL listed.
Not available on drawout breakers.
Not available for FCL or LCL breakers.
Not available on motor operated breakers.

Mounts on panel (not included) fitting over front of breakers. Standard
breaker spacing: LA Tri-Pac, NB TriPac: 8-1/2 inches; FB Tri-Pac: 4-3/16
inches center to center.

125

126

Cutler-Hammer

Molded Case Circuit Breakers
Accessories for Current Limiting Circuit Breakers

March 1999

Motor Operators➀
Motor operators provide complete
remote control by means of a pushbutton or similar pilot device➁.
Positive switching action is accomplished by use of an operating arm
engaging the breaker handle. The
unit is energized momentarily to
actuate the lever arm moving it to
either the “ON” or “OFF” position.
The control is broken by an internal
cutoff switch. Means for emergency
manual operation is provided.

For FB Tri-Pac/FCL Breakers

For LA Tri-Pac Breakers

For NB Tri-Pac Breakers

For PB Tri-Pac Breakers

Motor operators are available with
motors rated 120 volts Ac, 208 volts
Ac, and 240 volts Ac.
The 480 volt operators utilize a 120
volt Ac motor in conjunction with a
480/240 to 120 volt dual voltage
transformer. (On LA and larger operators, the transformer is supplied for
separate mounting by the customer.)
Note: The motor operator is
intended only for infrequent operation in line with Underwriters Laboratories, Inc. endurance standard for
AB molded case breakers.
Motor Operator Selection
Type
Breaker

Ac Voltage
120

Dc Voltage
208

240

480

125

24

Style Number

656D148G15
5664D54G83
656D148G11
2607D97G22
5664D54G65
5661D52G01

FCL
LCL
FB Tri-Pac
LA Tri-Pac
NB Tri-Pac
PB Tri-Pac

656D148G10
5664D54G86
656D148G04
2607D97G25
5664D54G68
5661D52G04

–
5664D54G88
–
–
–
–

–
5664D54G77
–
2607D97G44
5664D54G82
5661D52G17

656D148G17
5664D54G85
656D148G13
2607D97G24
5664D54G67
5661D52G03

656D148G17
5664D54G84
656D148G13
2607D97G23
5664D54G66
5661D52G02

Instruction Leaflet/FRED Number 13148 FCL; 15334 LCL; 13148 FB Tri-Pac; 15533 LA Tri-Pac; 15534 NB Tri-Pac; 14444 PB Tri-Pac

Back Mounting Plates
Type
Breaker

Motor Data

120, 208, 240, 480 Volts Ac
Style Number

Type
Breaker

Motor
Type

FB-P/FCL

Inrush Current,
Ampere (Peak)
Hp.

1282C01G01
FB Tri-Pac
LA Tri-Pac
NB Tri-Pac
PB Tri-Pac

Split Phase
Reversing
Reversing
Reversing

1/75
–
–
–

120
Volts

10
8
11
20

Continuous
Current (RMS)

208
Volts

240
Volts

120
Volts

4
5
7
12

5
4
6
11

2.3
–
–
–

208
Volts

1.17
–
–
–

Operating Time,
Open or Close
240
Volts

1.65
–
–
–

1.5 Seconds
12 Cycles
12 Cycles
10 Cycles

➀ Ac voltage rated operators are UL listed as
recognized components.
➁ The pilot device must be maintained contact
type for FB Tri-Pac, FCL, mechanisms;
momentary contact type for all others.

PG.74A.01.T.E

Cutler-Hammer

Molded Case Circuit Breakers
Accessories for Current Limiting Circuit Breakers

March 1999

Drawout Frame

These drawout frames are for use
with standard 3-pole Cutler-Hammer
molded case circuit breakers. They
consist of two separate parts; stationary mounting frame and movable carrier frame. Slide rails are
drawer-type, and a screw mechanism is used to engage or withdraw
the movable carrier frame.
The drawout frames have three
positions: connected, test and
disconnected. The frames do not
include a safety tripping interlock,
or secondary contacts. These are
optional items and may be ordered
at additional cost.

Secondary Contacts
These are used to disconnect auxiliary circuits when attachments such
as shunt trip or motor operator are
used. Available in multiples of four
contacts with a maximum of 32 contacts for the NB Tri-Pac. They must
be factory mounted. Order by
description as similar to stationary
or moving frame and specify number of contacts required.

Breakers mounted in the drawout
frames can be equipped with standard breaker accessories including
shunt trip, undervoltage release,
auxiliary switch, alarm switch and
motor operator.
Selection Data
Breaker Type➀

Stationary Mounting Frame
Style Number

NB Tri-Pac

2603D85G09

Standard Installation
Order one stationary mounting
frame and one movable carrier
frame.
Order breakers without terminals
or rear connectors.
Order any attachments desired
(shunt trip, undervoltage release,
etc.)
Order secondary contacts as
required:

➀ Drawout for FB and LA Tri-Pac, FCL, and LCL
Circuit Breakers are not available. PB Tri-Pac
movable is available factory-installed only.
Order by description.

PG.74A.01.T.E

■

A shunt trip, undervoltage release
or alarm switch requires two
contacts;

■

A 1A-1B auxiliary switch requires
three contacts;

■

A motor operator requires a
maximum of four contacts;

■

Others as required.

Movable Carrier Frame
Style Number

2608D34G12

Racking Crank
A special crank to engage or withdraw the moving portion of the
drawout. A standard 1/2 inch hex
socket with extension can be used
for this purpose.
Style Number

765A767G01

Cell Switches Mounted on
Drawout Frames, All Ratings
Up to four switches can be provided.
Order by description.
Each switch provides NO and NC
contact that transfers before reaching the test position when being
withdrawn, and after the test position when being racked in.

127

128

Molded Case Circuit Breakers

Cutler-Hammer
March 1999

PG.74A.01.T.E

Cutler-Hammer
March 1999

Molded Case Circuit Breakers
Engine Generator Circuit Breakers

129

General Information

Interrupting Capacity Ratings

Standards

Engine generator molded case circuit
breakers are designed specifically for
application on diesel engine powered standby generators where high
interrupting circuit breakers are not
required. The JG through NG breakers are equipped with a special trip
unit, that includes standard thermal
(overload) protection and special low
magnetic pickup range (FG includes
a fixed thermal/magnetic pickup).
The standard thermal trip unit
provides overload protection for
conductors per the National Electric
Code. The low magnetic pickup
range is approximately two to five
times the continuous rating and
provides closer low level short circuit
protection when applied on generators that have very low short circuit
capacity. This combination allows
the user to customize the breaker to
the generator output.

UL 489 Interrupting Capacity Ratings
Interrupting Capacity (Symmetrical
Amperes)
Volts Ac (50/60 Hz)
240
18,000
480
14,000
600
10,000

Engine generator molded case circuit breakers are designed to conform with the following standards:

IEC 947-2 Interrupting Capacity
Ratings
Interrupting Capacity (Symmetrical
Amperes)
Volts Ac (50/60 Hz)
220, 240
18,000/9,000
380, 415
14,000/7,000
660, 690
10,000/5,000

■

Underwriters Laboratories, Inc.,
Standard UL 489, Molded Case
Circuit Breakers and Circuit
Breaker Enclosures File E7819

■

Canadian Standards Association
Standard C22.2 No. 5, Service
Entrance and Branch Circuit
Breakers

■

International Electrotechnical
Commission Recommendations
IEC 947-2, Circuit Breakers

Conformance with these standards
satisfies most local and international
codes, assuming user acceptability
and simplified application.

Catalog Numbering System
This information is presented only
as an aid to understanding catalog
numbers. It is not to be used to build
catalog numbers for circuit breakers.
FG breakers include both line and
load side terminals.

FG 3 100 W
Frame

Number
of Poles

FG

3

JG, KG, LG, and NG breakers with
“W” catalog number suffix do not
include any terminals.
JG, KG, LG, and NG breakers without “W” catalog number suffix
include both line and load terminals.
Contact Cutler-Hammer for additional ratings and internal/external
accessories.

PG.74A.01.T.E

Trip
Amperes
15
20
25
30
35
40
45
50
60
70
80
90
100
125
150
175
200
225

JG

175
200
225
250

KG

300
350
400

LG

450
500
600

NG

700
800
900
1000
1200

Suffix

W: Without Terminals

Time/Current Curves, Dimension Sheets, Application Data

130

Cutler-Hammer

Molded Case Circuit Breakers
Engine Generator Circuit Breakers

March 1999

Circuit Breakers
are applied at 115% of the generator
full load current rating. The maximum
kW rating is based on three-phase
generators at 80% power factor.

The following table lists FG through
NG engine generator breakers with
the maximum generator kVA and kW
rating. Engine generator breakers
Magnetic Pickup
Range

Maximum Generator Rating 60 Hz
240 Vac

480 Vac

kVA➀

kW➁

Engine Generator
Breaker Catalog
Number

600 Vac

kVA➀

kW➁

kVA➀

kW➁

Fixed
Fixed
Fixed
Fixed

5
7
9
11

4
6
7
9

11
14
18
22

9
12
14
17

14
18
23
27

11
14
18
22

FG3015
FG3020
FG3025
FG3030

Fixed
Fixed
Fixed
Fixed

13
14
16
18

10
12
13
14

25
29
32
36

20
23
26
29

32
36
41
45

25
29
32
36

FG3035
FG3040
FG3045
FG3050

Fixed
Fixed
Fixed
Fixed

22
25
29
32

17
20
23
26

43
51
58
65

35
40
46
52

54
63
72
81

43
51
58
65

FG3060
FG3070
FG3080
FG3090

Fixed
Fixed
Fixed
Fixed
Fixed
Fixed
Fixed

36
40
45
54
63
72
81

29
32
36
43
51
58
65

72
79
90
108
126
144
162

58
64
72
87
101
116
130

90
99
113
135
158
181
203

72
79
90
108
126
144
162

FG3100
FG3110
FG3125
FG3150
FG3175
FG3200
FG3225

350-700

63

51

126

101

158

126

350-700

72

58

144

116

181

144

JG3175W➂
JG3175
JG3200W➂
JG3200

350-700

81

65

162

130

203

162

350-700

90

72

181

144

226

181

500-1000

108

87

217

173

271

217

500-1000

126

101

253

202

316

253

1000-2000

144

116

289

231

361

289

600-2500

162

130

325

260

406

325

600-2500

181

144

361

289

451

361

600-2500

217

173

433

347

542

433

800-2500

253

202

505

404

632

505

800-2500

289

231

578

462

722

578

1600-5000

325

260

650

520

812

650

1600-5000

361

289

722

578

903

722

1600-5000

433

347

867

693

1083

867

JG3225W➂
JG3225
JG3250W➂
JG3250
KG3300W➂
KG3300
KG3350W➂
KG3350
KG3400W➂
KG3400
LG3450
LG3450W➂
LG3500
LG3500W➂
LG3600
LG3600W➂
NG3700
NG3700W➂
NG3800
NG3800W➂
NG3900
NG3900W➂
NG31000
NG31000W➂
NG31200
NG31200W➂

➀ Breaker continuous current is based on 115%
of the generator full load ampere rating.
➁ Based on three-phase generators at 80%
power factor.
➂ Without terminals.

PG.74A.01.T.E

Cutler-Hammer

Molded Case Circuit Breakers
Engine Generator Circuit Breakers

March 1999

131

Enclosures

Enclosure Description
Type 1 General Purpose
■ Surface or Flush Mounting
■

15-1200 Ampere Range

■

600 Volts Ac, 500 Volts Dc

Type 12 Dustproof
Surface Mounting
■ No Knockouts or Other Openings

Type 3R Rainproof
Surface Mounting
■ Interchangeable Hubs
(Through 400 Amperes)

Type 1 enclosed breakers are
designed for use in commercial
buildings, apartment buildings and
other areas where a general purpose
enclosure is applicable. The breaker
is front operable and is capable of
being padlocked in either the On or
Off position. Ratings through 1200
amperes are listed with Underwriters Laboratories, Inc. as approved
for service entrance application.
Both surface and flush mounted
enclosures are available.

■

15-1200 Ampere Range

■

600 Volts Ac, 500 Volts Dc

This general purpose outdoor service center employs a circuit breaker
inside a weatherproof sheet steel
breaker enclosure to serve as a main
disconnect and protective device for
feeder circuits. Ratings through 1200
amperes are listed by Underwriters
Laboratories, Inc. as suitable for service entrance application.

■

15-1200 Ampere Range

■

600 Volts Ac, 500 Volts Dc

The Type 12 enclosure is designed
in line with specifications for special
industry application where unusually severe conditions involving oil,
coolant, dust and other foreign
materials exist in the operating
atmosphere. The handle padlocks in
the Off position and the cover is
interlocked with the handle mechanism to prevent opening the cover
with the circuit breaker in the On
position. Ratings through 1200
amperes are listed by Underwriters
Laboratories, Inc. as suitable for service entrance application.

E
B

C
E

E

C

C

ON
A

D

A

D

A

OFF

D

ON
OFF

B

Type 1 Surface Mounted

B

Type 3R Rainproof

Type 12, 12K Dustproof

Enclosure Selection Data
Breaker
Frame
(Amperes)

Enclosure
Type Class

Dimensions
A
Inches

B
mm

C

Inches

mm

D

Inches

mm

Inches

App.
Wt.
Lbs.

E
mm

Conduit Sizes,
Inches

Catalog
Number

Inches mm

FG
15-225

Type 1
Type 3R
Type 12

23.25
25.66
25.66

591
652
652

8.41
8.84
8.84

214
225
226

6.28
9.31
9.31

160
237
238

18.75
24.28
24.28

476
617
618

1.20
1.70
1.70

31
43
43

15
19
18

.25, .50, .75, 1, 1.25, 1.50, 2, 2.50
.25, .50, .75, 1, 1.25, 1.50, 2, 2.50

SFDN225
RFDN225
JFDN225

JG
175-250

Type 1
Type 3R
Type 12

34.70
37.50
37.53

881
891
953

10.92
11.56
11.56

227
294
294

7.20
10.22
10.22

183
260
260

30.00
35.77
35.77

762
909
909

1.88
1.94
1.94

48
49
49

31
40
37

.25, .50, 2, 2.50, 3
.25, .50, 2, 2.50, 3

SJDN250
RJDN250
JJDN250

KG
300-400

Type 1
Type 3R
Type 12

38.81
41.69
41.69

986
997
997

11.06
11.75
11.75

281
298
298

10.94
14.06
14.06

278
357
357

34.00
39.90
39.90

869
1014
1015

2.28
1.97
1.97

58
50
50

53
60
53

.25, .50, .75, 1.50, 2, 2.50, 3, 3.50
.25, .50, .75, 2.50, 3, 3.50

SKDN400
RKDN400
JKDN400

LG
450-600

Type 1
Type 3R
Type 12

45.88
48.31
48.31

1165
1227
1227

14.31
14.91
14.91

364
379
379

12.38
15.50
15.50

314
394
394

46.56
46.56
46.56

1183
1183
1183

1.91
1.92
1.92

48
49
49

81
84
81

.25, .50, .75, 3, 3.50, 4
.25, .50, .75, 3, 3.50, 4

SJDN600
RLDN600
JLDN600

NG
700-1200

Type 1
Type 3R
Type 12

61.22
63.59
63.59

1555
1615
1615

21.44
22.00
22.00

545
559
559

15.41
17.63
17.63

391
448
448

61.84
61.84
61.84

1571
1571
1571

1.97
1.97
1.97

50
50
50

178
175
170

PG.74A.01.T.E

SNDN1200
RNDN1200
JNDN1200

132

Cutler-Hammer

Molded Case Circuit Breakers
Engine Generator Circuit Breakers

March 1999

Accessories
Standard Terminals
Breaker
Frame

Maximum
Ampere
Rating

Internal Accessories
AWG Wire Range

Metric Wire
Range mm2

Catalog
Number

FG

100

#14-1/0

2.5 -50

3T100FB➀

FG

150

#4-4/0

25 -95

3TA225FD➀

JG

250

#4-350 kcmil

25 -185

TA250KB

KG

350

250-500 kcmil

120 -240

KG

400

3/0-250 kcmil (2)

95 -120

LG

600

250-500 kcmil (2)

120 -240

NG

700

1-500 kcmil (2)

50 -300

TA700NB1

NG

1000

3/0-400 kcmil (3)

95 -185

TA1000NB1

NG

1200

4/0-500 kcmil (4)

120 -300

TA1200NB1

TA350K
3TA400K➀

Breaker
Frame

Auxiliary Switch
1A-1B Catalog
Number

Shunt Trip
2A-2B Catalog
Number

Rating

Catalog
Number

FG

A1X1PK

A2X1PK

12-24 Vdc

SNT1LP03K

JG

A1X2PK

A2X2PK

12-24 Vdc

SNT2P04K

KG

A1X3PK

A2X3PK

12-24 Vdc

SNT3P05K

LG

A1X4PK

A2X4PK

12-24 Vdc

SNT4LP03K

NG

A1X5RPK

A2X5RPK

12-24 Vdc

SNT5LP03K

TA600LA

Neutral Kits, Insulated and Groundable
Maximum
Enclosure Rating
(Amperes)

Main Lug Number
Size Cu/Al

Ground Lug
Size Cu/Al

Catalog
Number

INK100

100

(1) 14–1/0

(1) 14–1/0

250

(1) 6–350 kcmil

(1) 4–300 kcmil

INK250

400

(1) 4–750 kcmil or
(2) 1/0–250 kcmil

(1) 4–300 kcmil

INK400

600

(2) 250–500 kcmil

(1) 4–300 kcmil

INK600

(3) 1/0 to 750 kcmil or
(4) 1/0 to 750 kcmil

(1) #6–250 kcmil

INK1200

1200

➀ Package of 3 terminals.

PG.74A.01.T.E

Cutler-Hammer

Molded Case Circuit Breakers
Series C Circuit Breakers for DC Applications

March 1999

For standard interrupting capacity
250 dc molded case circuit breakers.
Refer to Index, Page 1, for appropriate Series C frame size.

General Information
UL listed dc molded case circuit
breakers for use in general dc circuits and ungrounded battery supply
circuits of UPS systems providing
continuous, reliable ac power to
computer controlled applications
such as financial transactions and
telecommunications.

The Series C dc breakers listed
below use the same internal and
external accessories as the standard
Series C breaker. NBDC and PBDC
use same internal and external
accessories as standard NB and PB
breakers.

Interrupting Capacity Ratings
UL489 Interrupting Capacity Ratings
Interrupting Capacity (Symmetrical kA)

Circuit
Breaker
Type

Volts DC➀
125➁

HFDDC
HJDDC
HKDDC
HLDDC
HMDLDC
NBDC
PBDC

250➂

600➃

42
42
42
42
42
50
75

42
42
42
42
42
50
75

750➄

20
20
20
20
20
20
20

35
35
35
35
35
50
75

Series Connection Diagrams for DC Application➅
3-Poles in Series

4-Poles in Series
LOAD

LOAD
LOAD

➀ Dc ratings apply to substantially noninductive circuits. 8 millisecond time
constant.
➁ 1-pole in series.
➂ 2-poles in series.
➃ 3-poles in series.
➄ 4-poles in series. Not a UL listed voltage
rating.
➅ Use rated cable per NEC Connect to
terminals as per breaker nameplate.

PG.74A.01.T.E

Molded case circuit breakers for
transportation application requiring
750 Vdc are available 15 through
2500 ampere 20 kA interrupting
capacity at 750 Vdc. Breakers require
4 poles in series for 750 Vdc application. However, 750V is not a UL rating. For 750 Vdc application refer to
Cutler-Hammer for ordering information. Dimensions are the same
as the standard thermal-magnetic
equivalent.

133

Time/Current Curves, Dimension Sheets, Application Data

134

Cutler-Hammer

Molded Case Circuit Breakers
Series C Circuit Breakers for DC Applications

Type HFDDC DC Circuit Breakers
Maximum
Continuous
Ampere Rating
@ 40°C

Type HKDDC DC Circuit Breakers

Complete Circuit Breaker with Line and Load Terminals
1-Pole

2-Pole

3-Pole

Catalog Number

HFDDC1015L
HFDDC1020L
HFDDC1025L
HFDDC1030L
HFDDC1035L
HFDDC1040L
HFDDC1045L
HFDDC1050L
HFDDC1060L
HFDDC1070L
HFDDC1080L
HFDDC1090L
HFDDC1100L
HFDDC1110L
HFDDC1125L
HFDDC1150L
–
–
–

HFDDC2015L
HFDDC2020L
HFDDC2025L
HFDDC2030L
HFDDC2035L
HFDDC2040L
HFDDC2045L
HFDDC2050L
HFDDC2060L
HFDDC2070L
HFDDC2080L
HFDDC2090L
HFDDC2100L
HFDDC2110L
HFDDC2125L
HFDDC2150L
–
–
–

Maximum
Continuous
Ampere Rating
@ 40°C

HFDDC3015L
HFDDC3020L
HFDDC3025L
HFDDC3030L
HFDDC3035L
HFDDC3040L
HFDDC3045L
HFDDC3050L
HFDDC3060L
HFDDC3070L
HFDDC3080L
HFDDC3090L
HFDDC3100L
HFDDC3110L
HFDDC3125L
HFDDC3150L
HFDDC3175L
HFDDC3200L
HFDDC3225L

Thermal Magnetic
Trip Unit

TA350K
TA350K
TA350K
3TA400K

300
350
400
450
500
600

HLDDC3600F

LT3300T
LT3350T
LT3400T
LT3450T
LT3500T
LT3600T

TA602LD
TA602LD
TA602LD
TA602LD
TA602LD
3TA603LDK

Instruction Leaflet/FRED Number 29C702

Type HMDL DC Circuit Breakers
Maximum
Continuous
Ampere Rating
@ 40°C

100
125
150
175
200
225

HKDDC3400F

TA250KB
TA250KB
TA250KB
TA250KB
TA250KB
TA250KB
TA250KB
TA250KB
TA250KB

KT3100T
KT3125T
KT3150T
KT3175T
KT3200T
KT3225T

TA300K
TA300K
TA300K
TA300K
TA300K
TA300K

Instruction Leaflet/FRED Number 29C701

Thermal Magnetic
Trip Unit

Catalog Number

HMDL3800F

300
350
400
450
500
600
700
800

Standard
Terminals

JT3070T
JT3090T
JT3100T
JT3125T
JT3150T
JT3175T
JT3200T
JT3225T
JT3250T

Circuit Breaker
Frame Only➀

3-Pole High Interrupting Capacity 35 kAIC @ 600 Vac

3-Pole High Interrupting Capacity 35 kAIC @ 600 Vac
HJDDC3250F

Catalog Number

KT3250T
KT3300T
KT3350T
KT3400T

Catalog Number

70
90
100
125
150
175
200
225
250

Standard
Terminals

HKDDC3400F

Type HJDDC DC Circuit Breakers
Circuit Breaker
Frame Only➀

Thermal Magnetic
Trip Unit

250
300
350
400

Instruction Leaflet/FRED Number 29C700

Maximum
Continuous
Ampere Rating
@ 40°C

Circuit Breaker
Frame Only➀

3-Pole High Interrupting Capacity 35 kAIC @ 600 Vac

1, 2, 3-Pole High Interrupting Capacity 35 kAIC @ 600 Vac
15
20
25
30
35
40
45
50
60
70
80
90
100
110
125
150
175
200
225

March 1999

MT3300T
MT3350T
MT3400T
MT3450T
MT3500T
MT3600T
MT3700T
MT3800T

Type NBDC DC Circuit Breakers
Maximum
Continuous
Ampere
Rating
@ 40°C

Complete Circuit
Breaker Factory
Assembled
Without
Terminals➀

Includes Magnetic
Only Trip Unit
Calibrated @ 135%

Standard
Terminals

Catalog Number

3-Pole High Interrupting Capacity 50 kAIC @ 600 Vac
700
800
900
1000
1200

NBDC3700MW
NBDC3800MW
NBDC3900MW
NBDC31000MW
NBDC31200MW

Included
Included
Included
Included
Included

TA1000NB1
TA1000NB1
TA1000NB1
TA1000NB1
TA1200NB1

Type PBDC DC Circuit Breakers
Maximum
Continuous
Ampere
Rating
@ 40°C

Complete Circuit
Breaker Factory
Assembled
Without
Terminals➀

Includes Magnetic
Only Trip Unit
Calibrated @ 135%

Standard➁
Terminals

Catalog Number

3-Pole High Interrupting Capacity 75 kAIC @ 600 Vac
1600
2000
2500

PBDC31600W
PBDC32000W
PBDC32500W

Included
Included
Included

BA2000PB
BA2000PB
BA2500PB

Instruction Leaflet/FRED Number 15560

➀ Complete circuit breaker includes frame, trip
unit, and terminals.

PG.74A.01.T.E

Cutler-Hammer
March 1999

Molded Case Circuit Breakers
Add-on Ground Fault Protection
Type GFM

Type GFM
Reset Indicator Button
Interchangeable
Rating Plug

designated either GFM2 or GFM4,
employs an internal relay having
S.P.D.T. contacts that will operate a
remote shunt trip device where control power is available.
The second type, designated either
GFM2A or GFM4A. is completely
solid state with an output SCR circuit
designed to operate a remote, lowenergy, flux transfer shunt trip
mounted in a molded case breaker.
No supplementary control power for
the shunt trip is required.

Size Selection

Rating
Plug
Type GFM Ground Fault Protection Device

Description
Cutler-Hammer Type GFM devices
are Class 1 Ground Fault Sensing
and Relaying devices designed to
comply with the requirements outlined in Underwriters Laboratories,
Inc. Standards for Safety entitled:
Ground Fault Sensing and Relaying
Equipment, UL1053.
Type GFM devices, when properly
installed on a grounded electrical
distribution system, will sense phase
to ground fault currents and cause a
disconnect to open and clear the
fault instantaneously at predetermined current values. These devices
have a maximum voltage rating of
600V, 50/60 Hertz and may be
applied in accordance with Article
230-95 of the National Electrical
Code.
Type GFM Ground Fault Protective
Devices are self-contained combination sensing and relaying devices
designed primarily for application
on motor circuits and fixed loads
where low-level Ground Fault Equipment Protection is required.
GFM devices are available in two
basic types with each type having
two physical sizes. The two basic
types differ in the type of output
circuit provided. The first type,

PG.74A.01.T.E

Trip Indication/Reset
A combination visual indicator and
reset button is provided on the top
of Type GFM2 and GFM4 devices to
indicate the initiation of a tripping
action to clear a Ground Fault. The
operation of the internal relay will
cause the white button to visibly
raise.
To reset the device, the Indicator/
Reset button must be depressed.
Failure to reset the device will not
allow the associated disconnect
device to be reclosed.

The proper size selection is a function of the conductor size of the
equipment being protected. Types
GFM2/GFM2A have approximately a
two-inch window opening. Types
GFM4/GFM4A have approximately a
four-inch window opening.

No Indicator/Reset button is provided on Types GFM2A or GFM4A
since an internal SCR is used in the
output circuit. These devices reset
automatically when the disconnect
opens to clear the Ground Fault.

Rating Selection

Type GFM devices may be installed
in Zero Sequence or Ground Return
Sensing methods, Proper Ground
Fault Protection schemes are dependent upon proper system installation
and grounding methods.

The basic Ground Fault Current
Pickup rating of either type GFM
device is 5 amperes, i.e., each unit
when properly installed will initiate a
trip signal to a remote shunt trip
with the presence of a 5 ampere
Ground Fault Current within established tolerance limits. Separate
optional rating plugs are available to
alter the pickup rating to a maximum
of 100 amperes.

Control Power
Internal control power is not
required to operate Type GFM
Ground Fault Protective devices. All
internal control power required is
derived from the Ground Fault current through the internal current
sensor.
External control power is required to
operate the remote shunt trips used
in conjunction with Type GFM2 and
GFM4 devices.
External control power is not
required with Type GFM2A and
GFM4A devices to operate the special remote, low-energy, flux transfer
shunt trips used in molded case circuit breakers.

Application

Mounting
Each Type GFM device contains a
Ground Fault Sensor which is a special current transformer. These are
insulated devices which can be
mounted directly to enclosure surfaces. Four tubular rivets secure the
sensor housing. These four (0.200
dia.) mounting holes can be used
to mount the GFM device in either
a vertical or horizontal mounting
position.
Optional mounting brackets as
shown on the next page are available.
These brackets may be mounted on
either the bottom or side depending
upon the installation requirements.
Regardless of the mounting method
used, the top of the device with the
visual indicator/ reset button and
nameplate instructions should be
maintained in a visual position after
installation. GFM devices should be
installed so that all conductors passing through the conductor window
are physically centered.

135

Time/Current Curves, Dimension Sheets, Application Data

136

Cutler-Hammer

Molded Case Circuit Breakers
Add-on Ground Fault Protection

March 1999

Type GFM

Ordering Information

Selection Data

Order by catalog number or style
number:

GFM Basic Units
Output Type

1 Basic GFM Unit

Approximate Window
Opening, Inches

Basic Ampere Rating
(Plug Omitted)

Operating Time
@ 10 x Ampere Rating

Catalog Number

Unit for Use with Standard Shunt Trip

1 Rating plug if required
1 Mounting bracket if required
1 Circuit breaker with standard
shunt trip factory installed
(as required), or optionally when
possible, a circuit breaker and field
mountable shunt trip as separate
items.

Rating Plug Installation
To install an optional rating plug to
obtain other than the minimum
5 ampere rating, remove the terminal cover held in position by a single
screw and retention groove. With
the cover removed, insert the rating
plug in the position indicated. The
rating plug is held captive in position
with the addition of the terminal
cover after the wiring is completed.
With the terminal cover in position,
the ampere rating of the rating plug
remains visible.

Relay
Relay

2
4

5
5

0.03 Seconds
0.03 Seconds

GFM2
GFM4

5
5

0.03 Seconds
0.03 Seconds

GFM2A
GFM4A

Unit for Use with Flux Transfer Shunt Trips
SCR
SCR

2
4

Instruction Leaflet/FRED Number 14945

GFM Optional Rating Plugs
Ampere Rating

10
25
50
50
100

Optional Mounting Brackets

Catalog Number

GFMP10
GFMP25
GFMP50
GFMP75
GFMP100

Includes two (2) brackets and mounting hardware

GFM
Type

Bracket Kit
Style Number

GFM2/2A
GFM4/4A

750B295G01
750B295G02

Output Circuitry
Contact ratings for Type GFM2 and
GFM4 are 10 amperes continuous,
240 volts Ac maximum. Types
GFM2A and GFM4A are intended to
be used only with remote flux transfer shunt trips.

PG.74A.01.T.E

Cutler-Hammer
March 1999

Molded Case Circuit Breakers
Add-on Ground Fault Protection

137

Type GFR

Type GFR
Description
The GFR ground fault relays, current
sensors, test panels and accessory
devices are UL listed by Underwriters Laboratories, Inc. in accordance
with their standard for Ground Fault
Sensing and Relaying Equipment,
UL 1053, under File E48381.➀
A Type GFR ground fault protection
system, when properly installed on a
grounded electrical system, will
sense phase-to-ground fault currents. When the level of fault current
is in excess of the pre-selected current pickup and time delay settings,
the GFR relay will initiate a trip
action of a disconnect device, which
will open the faulted circuit and clear
the fault.
The GFR devices are UL Class I
devices designed to protect electrical equipment against extensive
damage from arcing ground faults.
A basic Type GFR ground fault protection system consists of a ground
fault relay➁, a ground fault current
sensor and a disconnect device
equipped with a shunt trip device.
This disconnect device can be a
molded case circuit breaker, a power
circuit breaker, a bolted pressure
switch or other fusible disconnect
device, suitable for application with
UL Class I Ground Fault Sensing and
Relaying equipment.
Additional optional equipment can
be added to the protection system to
meet the requirements of the specifying engineer, including:
■

Ground Fault Test Panel

■

Ground Fault Warning Indicator
Relay

■

Ground Fault Indicating Ammeter

GFR relays are available with zone
selective interlocking circuitry to
interlock several relays within the
same system. This allows the relay
which detects a ground fault to
➀ Suitable for either surface or semi-flush
mounting.
➁ These devices are also listed with CSA under
their file number 43357.

PG.74A.01.T.E

GFR Relay

instantly clear the fault by tripping
the disconnect device. The relay
simultaneously sends a signal to
relay units “upstream” from the
fault to time delay or to block their
operation completely. Current sensors in various designs provide a
range of “window” sizes to accommodate standard bus and cable
arrangements.
Shunt trip attachments may be
ordered for field mounting in CutlerHammer molded case circuit breakers, or may be ordered factory
installed in the breaker.

Electrical Ratings

Typical Current Sensor

GFR Relay
Ground Fault Detection Ranges:
1 to 12, 5 to 60 or 100 to 1200
Amperes
Output contacts:
240 Volt, 50/60 Hz:
120 Volt, 50/60 Hz:
28 Volt Dc:
125 Volt Dc:

3.0
6.0
3.0
.5

Amperes
Amperes
Amperes
Amperes

Control power requirements:
120 Volt, 50/60 Hz: .125 Amperes, or
125 Volt Dc (optional)

Sensor:
600 Volts, 50/60 Hz maximum
system voltage

Time/Current Curves, Dimension Sheets, Application Data

138

Cutler-Hammer

Molded Case Circuit Breakers
Add-on Ground Fault Protection

March 1999

Type GFR

Ordering Information

Accessories

Each installation requires:
1. One relay unit (select trip ampere
as required)
2. One current sensor (select configuration required)

3. One circuit breaker or disconnect
device with shunt trip, or a shunt
trip attachment for mounting in
existing breaker.
4. Test panel. (Optional)

GFR Relay
Catalog Numbers➀

GFR Relay
Types

Optional Test Panel

Ground Fault Pickup Amperes
1-12

Control

5-60

Electrical Reset with Zone Interlocking

GRF12EI

GFR60EI

GFR1200EI

Electrical Reset without Zone Interlocking

GRF12E

GFR60E

GFR1200E

Mechanical Reset with Zone Interlocking

GRF12MI

GFR60MI

GFR1200MI

Mechanical Reset without Zone Interlocking

GRF12MI

GFR60MI

GFR1200MI

For 120 Volt Dc Control
Electrical Reset with Zone Interlocking

GRF12EID

GFR60EID

GFR1200EID

Electrical Reset without Zone Interlocking

GRF12ED

GFR60ED

GFR1200ED

Mechanical Reset with Zone Interlocking

GRF12MID

GFR60MID

GFR1200MID

Mechanical Reset without Zone Interlocking

GRF12MID

GFR60MID

GFR1200MID

Current Sensor
Style Number

Used with Relays Rated 1-12 Amperes
5.50 In. I.D.

1283C45G01

Used with Relays Rated 5-60 Amperes
2.50 In. I.D.
5.50 In. I.D.
8.25 In. I.D.
7.81 x 11.00 In.
3.31 x 24.94 In.

Rect.➁
Rect.➁

179C768G01
1256C13G01
179C767G01
1257C88G04
1257C92G03

Rect.➁
Rect.➁
Rect.➁
Rect.➁
Rect.➁
Rect.➁

179C768G02
1256C13G02
179C767G02
1257C88G03
1257C90G02
1257C91G02
1257C89G02
1257C92G04
1255C39G03

Used with Relays Rated 100-1200 Amperes

7.81 x
9.94 x
9.94 x
15.94 x
3.31 x
6.75 x

2.50 In. I.D.
5.50 In. I.D.
8.25 In. I.D.
11.00 In.
16.94 In.
23.94 In.
19.94 In.
24.94 In.
29.64 In.

Instruction Leaflet/FRED Number 15321

Test

Catalog Number

100-200

For 120 Volt 50/60 Hz Control

Window Size

Test Panel (120 Volts Ac)➂
Used to test the ground fault system,
to give an indication the relay has
tripped the breaker, and to reset the
relay after tripping➃. These functions
may be separately mounted pilot
devices.

120V 50/60 Hz

120V 50/60 Hz

GFRTP

125V Dc

120V 50/60 Hz

GFRTPD

Ground Fault Warning Indicator
This is an accessory item for use with
GFR Relays with interlocking circuitry. At approximately 30-50% of
the Relay pickup setting, the indicator switches separate 120 volt Ac
control power to a lamp or relay, (not
included) to give an indication of a
ground fault. The indicator is rated
110/120 volts Ac 50/60 Hz
for a maximum indicator load of
.5 amperes.
Ground Fault Warning
Indicator

Style Number

Manual Reset

1234C67G01

Self-Resetting

1234C67G02

Indicating Ammeter➃
The optional indicating ammeter. It
connects to the sensor terminals,
through a momentary contact
pushbutton, and will indicate (in
amperes) any ground fault current
flowing through the sensor. Kit
includes the ammeter and pushbutton.
GFR System
Used with

1-12 Ampere
5-60 Ampere
100-1200 Ampere

Kit Style
Number

752B820G01
752B820G02
752B820G03

Shunt Trip Attachments
Use 120 volt Ac shunt trips.

➀ Suitable for either surface or semi-flush
mounting.
➁ One end removable for installation.
➂ When a mechanically reset relay is used with
a test panel, both the relay and test panel
must be reset following either a simulated
ground fault test or actual ground fault.
➃ Not UL listed.

Face Plate
Recommended when these relays
are semi-flush mounted, to close the
door cutout opening.
Description

Face Plate

Style Number

752B410G01

PG.74A.01.T.E

Cutler-Hammer

Molded Case Circuit Breakers
Series C Internal Accessories

March 1999

139

Alarm Switch

Alarm Switch

General Information
For remote indication of automatic
trip operation. Does not function
with manual switching; however, it
will operate when either a shunt trip
or undervoltage release is operated.

Make
Break

A “make” contact closes and a
“break” contact opens when the
alarm/lockout switch operates. The
switch automatically resets when
the circuit breaker is reset.

Ordering Information
G-Frame

Alarm Switch (RH only)➀
Electrical Rating
Volts

Frequency

Contact
Arrangement

Amperes

Style
Number➁➂➃

Factory
Suffix

Alarm Switch
240

50/60 Hz

6

1 Make/ 1 Break

1288C75G03

B3

1 Make/ 1 Break
and 1a/1b

1288C76G09

B13

Alarm Switch Auxiliary Switches Combination
240

50/60 Hz

6

Instruction Leaflet/FRED Number 15552

F-Frame
Alarm Switch➀

Electrical Rating Data➄➅
Maximum
Voltage

Frequency

Maximum
Current
Amperes

Dielectric
Withstand
Voltage

Multi-Pole Circuit Breakers
600
125
250

50/60 Hz
Dc
Dc

6
0.50➆
0.25➆

Number of
Contacts
(Make and
Break)

Mounting
Location
(Pole)

Factory Mounted

Field Mounted

Connection Type and Location

Field Installation Kits➈

18-Inch Pigtail Leads

2500
2200
2200

Same
Side

Terminal
Block

Rear➉

Opposite
Side

Pigtail
Leads

Terminal
Block

Same
Side

Suffix Number

Catalog Number

Single-Pole Circuit Breakers
125/250
28
28

50/60 Hz
Dc
Dc

6➆
3➆
5➇

2000
2000
2000

1

Left
Right

B01
B05

B02
B06

B03
B07

B04
B08

A1L1LPK
A1L1RPK

A1L1LTK
A1L1RTK

2

Left
Right

B09
B12

B10
B13

–
–

B11
B14

A2L1LPK
A2L1RPK

A2L1LTK
A2L1RTK

1 (Make
Only)

Single
Pole

B15

–

–

–

–

–

Instruction Leaflet/FRED Number 29C180

➀ F-Frame circuit breakers are factory sealed.
Underwriters Laboratories, Inc., requires
that internal accessories be installed at
the factory. Internal accessories are UL listed
for factory installation under E7819. Where
local codes and standards permit and UL
listing is not required, internal accessories
can be field installed. Accessory installation
should be done before the circuit breaker is
mounted and connected.
➁ Includes 24-inch external pigtail leads,18
AWG (16-.010).
➂ A maximum of two internal accessories may
be mounted in a three-pole circuit breaker.

PG.74A.01.T.E

➃ Suitable for mounting in right pole only of
2- or 3-pole breaker.
➄ Endurance: 6000 electrical operations plus
4000 mechanical operations.
➅ Endurance: 6000 electrical operations plus
2000 mechanical operations.
➆ Non-inductive load.
➇ Inductive (L/R = 0.026).
➈ Not listed with Underwriters Laboratories,
Inc., for field installation.
➉ Standard pigtail lead exit location.
 Standard mounting location.
 Factory installation only. Leads exit load end
of circuit breaker.

140

Cutler-Hammer

Molded Case Circuit Breakers
Series C Internal Accessories

March 1999

Alarm Switch

J-Frame
Electrical Rating Data➀➁
Maximum
Voltage

600
125
250

Frequency

50/60 Hz
Dc
Dc

Maximum
Current
Amperes

6
0.50➂
0.25➂

Alarm Switch
Dielectric
Withstand
Voltage

Number of
Contacts
(Make and
Break)

Mounting
Location
(Pole)

Factory Mounted

Field Mounted

Connection Type and Location

Field Installation Kits➃

18-Inch Pigtail Leads

2500

Same
Side

Rear➄

Terminal
Block
Opposite
Side

Left➅
Right

Terminal
Block

Same
Side

Suffix Number

1

Pigtail
Leads

Catalog Number

B01
B05

B02
B06

B03
B07

B04
B08

A1L2LPK
A1L2RPK

A1L2LTK
A1L2RTK➆

Instruction Leaflet/FRED Number 29C181

K-Frame
Alarm Switch

Electrical Rating Data➁➇
Maximum
Voltage

600
125
250

Frequency

50/60 Hz
Dc
Dc

Maximum
Current
Amperes

6
0.50➂
0.25➂

Dielectric
Withstand
Voltage

Number of
Sets of
Contacts
(1M and 1B)

Mounting
Location
(Pole)

Factory Mounted

Field Mounted

Connection Type and Location

Field Installation Kits➃

18-Inch Pigtail Leads

2500

Same
Side

Rear➄

Terminal
Block
Opposite
Side

Pigtail
Leads

Terminal
Block

Same
Side

Suffix Number

Catalog Number

1

Left➅
Right

B01
B05

B02
B06

B03
B07

B04
B08

A1L3LPK
A1L3RPK

A1L3LTK
A1L3RTK

2

Left➅
Right

B09
B12

B10
B13

–
–

B11
B14

A2L3LPK
A2L3RPK

A2L3LTK
A2L3RTK

Instruction Leaflet/FRED Number 29C182

L- and M-Frames
Electrical Rating Data➁➇
Maximum
Voltage

600
125
250

Frequency

50/60 Hz
Dc
Dc

Maximum
Current
Amperes

6
0.50➂
0.25➂

Alarm Switch
Dielectric
Withstand
Voltage

Number of
Sets of
Contacts
(1M and 1B)

Mounting
Location
(Pole)

Factory Mounted

Field Mounted

Connection Type and Location

Field Installation Kits➃

18-Inch Pigtail Leads

2500

Same
Side

Rear➄

Terminal
Block
Opposite
Side

Pigtail
Leads

Terminal
Block

Same
Side

Suffix Number

Catalog Number

1

Left➅
Right

B01
B05

B02
B06

B03
B07

B04
B08

A1L4LPK
A1L4RPK

A1L4LTK
A1L4RTK

2

Left➅
Right

B09
B12

B10
B13

–
–

B11
B14

A2L4LPK
A2L4RPK

A2L4LTK
A2L4RTK

Instruction Leaflet/FRED Number 29C183

➀ Endurance: 6000 electrical operations plus
2000 mechanical operations.
➁ Pigtail wire size: No. 18 AWG (0.82 mm2).
➂ Non-inductive load.
➃ Listed with Underwriters Laboratories, Inc.,
for field installation on interchangeable trip
unit breakers under E64983.
➄ Standard mounting location.
➅ Standard mounting location – leads exit rear
of breaker.
➆ Not for use on 4-pole circuit breakers.
➇ Endurance – 5,000 electrical operations plus
1000 mechanical operations.

PG.74A.01.T.E

Cutler-Hammer

Molded Case Circuit Breakers
Series C Internal Accessories

March 1999

141

Alarm Switch

N-Frame
Alarm Switch

Electrical Rating Data➀
Maximum
Voltage

Frequency

600
125
250

Maximum
Current
Amperes

50/60 Hz
Dc
Dc

6
0.50➁
0.25➁

Dielectric
Withstand
Voltage

2500

Number of
Sets of
Contacts
(Make and
Break)

Mounting
Location
(Pole)

Factory Mounted

Field Mounted

Connection Type and Location

Field Installation Kits➂

18-Inch Pigtail Leads
Same
Side

Rear➃

Terminal
Block
Opposite
Side

Pigtail
Leads

Same
Side

Suffix Number

Catalog Number

1

Left
Right➃

B01
B05

B02
B06

B03
B07

B04
B08

A1L5LPK
A1L5RPK

A1L5LTK
A1L5RTK

2

Left
Right➃

B09
B12

B10
B13

–
–

B11
B14

A2L5LPK
A2L5RPK

A2L5LTK
A2L5RTK

Instruction Leaflet/FRED Number 29C184

R-Frame
Alarm Switch (RH only)

Electrical Rating Data➄➅
Maximum
Voltage

600
125
250

Frequency

50/60 Hz
Dc
Dc

Maximum
Current Amperes

Number of
Contacts
(Make and Break)

6
0.50➁
0.25➁

Factory Mounted

Field Mounted

Connection Type and Location

Field Installation Kits➂

18-Inch Pigtail Leads

Pigtail Leads

Suffix Number➆

Catalog Number➆

1

B05

A1L6RPK

2

B12

A2L6RPK

Instruction Leaflet/FRED Number 29C185

➀ Endurance – 3000 electrical operations plus
1000 mechanical operations.
➁ Non-inductive load.
➂ Listed with Underwriters Laboratories, Inc.
for field installation under E64983.
➃ Standard mounting location – leads exit rear
of breaker.
➄ Endurance: 500 electrical operations plus
2500 mechanical operations.
➅ Pigtail wire size: No. 18 AWG (0.82 mm2).
Leads are red, black and blue.
➆ A maximum of three ASL plug-in modules
may be installed in a circuit breaker.

PG.74A.01.T.E

Terminal
Block

Cutler-Hammer

Molded Case Circuit Breakers
Series C Internal Accessories

142

March 1999

Auxiliary Switch

Auxiliary Switch

General Information
The auxiliary switch provides circuit
breaker contact status information
by monitoring the position of the
molded cross bar which contains the
moving contact arms. The auxiliary
switch is used for remote indication
and interlock system verification,

a
b

and consists of one or two SPDT
switches housed in a plug-in module. Each SPDT switch has one “a”
and one “b” contact. When the circuit breaker contacts are open, the
“a” contact is open and the “b”
contact is closed.

Ordering Information
G-Frame

Auxiliary (RH only)
Electrical Ratings
Volts

Frequency

240
240

Contact
Arrangement

Amperes

50/60 Hz
50/60 Hz

6
6

Style
Number➀➁➂

1a/1b
2a/2b

Factory
Suffix

1288C74G03
1288C73G03

A3
A6

Instruction Leaflet/FRED Number 15551

F-Frame
Electrical Rating Data➃➄
Maximum
Voltage

Frequency

125➅
600
125
250

50/60 Hz
50/60 Hz
Dc
Dc

Maximum
Current
Amperes

1
6
0.50➆
0.25➆

Auxiliary Switch
Dielectric
Withstand
Voltage

Number of
Contacts
a and b

Mounting
Location
(Pole)

2500
2500
2200
2200

Factory Mounted

Field Mounted

Connection Type and Location

Field Installation Kits➇

18-Inch Pigtail Leads
Same
Side

Rear➈

Terminal
Block
Opposite
Side

Left➄
Right or
Neutral

2

Left➄
Right or
Neutral

Terminal
Block

Same
Side

Suffix Number

1

Pigtail
Leads

Catalog Number

A01
A15➉
A05
A18➉

A02
A16➉
A06
A19➉

A03
A17➉
A07
A20➉

A04
–
A08
–

A1X1PK
E1X1PK
A1X1PK
–

A1X1LTK
–
A1X1RTK
–

A09
A21➉
A12
A23➉

A10
A22➉
A13
A24➉

–
–
–
–

A11
–
A14
–

A2X1LPK
E2X1LPK
A2X1RPK
E2X1RPK

A2X1LTK
–
A2X1RTK
–

Instruction Leaflet/FRED Number 29C120

J-Frame
Auxiliary Switch

Electrical Rating Data➃➄
Maximum
Voltage

600
125
250

Frequency

50/60 Hz
Dc
Dc

Maximum
Current
Amperes

6
0.50➆
0.25➆

Dielectric
Withstand
Voltage

Number of
Sets of
Contacts
(1a and 1b)

Mounting
Location
(Pole)

Factory Mounted

Field Mounted

Connection Type and Location

Field Installation Kits

18-Inch Pigtail Leads

Terminal
Block

2500
Same
Side

Rear

Opposite
Side

Terminal
Block

Same
Side

Suffix Number

➀ Includes 24-inch external pigtail leads,
#18 AWG (16-.010).
➁ A maximum of two internal accessories may
be mounted in a three-pole circuit breaker.
➂ Suitable for mounting in right pole only of
2- or 3-pole breaker.
➃ Endurance: 6000 electrical operations plus
4000 mechanical operations.
➄ Pigtail wire size: No. 18 AWG (0.82 mm2).
➅ For use in electronic circuit of 100 microamperes and 15 Vdc minimum.
➆ Non-inductive load.

Pigtail
Leads

Catalog Number

1

Left
Right

A01
A05

A02
A06

A03
A07

A04
A08

A1X2PK
A1X2PK

A1X2LTK
A1X2RTK

2

Left
Right

A09
A12

A10
A13

–
–

A11
A14

A2X2PK
A2X2PK

A2X2LTK
A2X2RTK

Instruction Leaflet/FRED Number 29C121
➇ Not listed with Underwriters Laboratories,
Inc., for field installation.
➈ Standard pigtail lead exit location.
➉ 125-volt (Max.), 50/60 Hz switch for use in
electronic circuit of 100 micro-amp and 15
Vdc minimum.






Listed with Underwriters Laboratories, Inc.
for field installation or interchangeable trip
unit breakers under E64983.
Standard mounting location – leads exit rear
of breaker.
Not for use on 4-pole circuit breakers.

PG.74A.01.T.E

Cutler-Hammer

Molded Case Circuit Breakers
Series C Internal Accessories

March 1999

143

Auxiliary Switch

K-Frame
Electrical Rating Data➀➁
Maximum
Voltage

Frequency

600
125
250

Maximum
Current
Amperes

50/60 Hz
Dc
Dc

6
0.50➂
0.25➂

Auxiliary Switch
Dielectric
Withstand
Voltage

Number of
Sets of
Contacts
(1M and 1B)

Mounting
Location
(Pole)

Factory Mounted

Field Mounted

Connection Type and Location

Field Installation Kits➃

18-Inch Pigtail Leads

2500

Same
Side

Terminal
Block

Rear➄

Opposite
Side

Pigtail
Leads

Terminal
Block

Same
Side

Suffix Number

Catalog Number

1

Left
Right➄

A01
A05

A02
A06

A03
A07

A04
A08

A1X3PK
A1X3PK

A1X3LTK
A1X3RTK➅

2

Left
Right➄

A09
A12

A10
A13

–
–

A11
A14

A2X3PK
A2X3PK

A2X3LTK
A2X3RTK➅

3

Left
Right

A18
A17

–
–

–
–

A15
A16

A3X3LPK
A3X3RPK

A3X3LTK
A3X3RTK➅

Instruction Leaflet/FRED Number 29C122

L- and M-Frames
Auxiliary Switch

Electrical Rating Data➁
Maximum
Voltage

Frequency

600
125
250

50/60 Hz
Dc
Dc

Maximum
Current
Amperes

6
0.50➂
0.25➂

Dielectric
Withstand
Voltage

Number of
Sets of
Contacts
(1a and 1b)

Mounting
Location
(Pole)

Factory Mounted

Field Mounted

Connection Type and Location

Field Installation Kits➃

18-Inch Pigtail Leads

2500

Same
Side

Terminal
Block

Rear➄

Opposite
Side

Catalog Number

1

Left
Right➄

A01
A05

A02
A06

A03
A07

A04
A08

A1X4PK
A1X4PK

A1X4LTK
A1X4RTK➅

2

Left
Right➄

A09
A12

A10
A13

–
–

A11
A14

A2X4PK
A2X4PK

A2X4LTK
A2X4RTK➅

3

Left
Right➄

A18
A17

–
–

–
–

A15
A16

A3X4PK
A3X4PK

A3X4LTK
A3X4RTK➅

Instruction Leaflet/FRED Number 29C123

PG.74A.01.T.E

Terminal
Block

Same
Side

Suffix Number

➀ Endurance – 5000 electrical operations plus
1000 mechanical operations.
➁ Pigtail wire size – No. 18 AWG (0.82 mm2).
➂ Non-inductive load.
➃ Listed with Underwriters Laboratories, Inc.
for field installation under E64983.
➄ Standard mounting location – leads exit rear
of breaker.
➅ Not for use on 4-pole circuit breaker.

Pigtail
Leads

144

Cutler-Hammer

Molded Case Circuit Breakers
Series C Internal Accessories

March 1999

Auxiliary Switch

N-Frame
Electrical Rating Data➀➁
Maximum
Voltage

600
125
250

Frequency

Auxiliary Switch

Maximum
Current
Amperes

50/60 Hz
Dc
Dc

6
0.50➂
0.25➂

Dielectric
Withstand
Voltage

Number of
Sets of
Contacts
(1A and 1B)

Mounting
Location
(Pole)

Factory Mounted

Field Mounted

Connection Type and Location

Field Installation Kits➃

18-Inch Pigtail Leads

2500

Same
Side

Terminal
Block

Rear➄

Opposite
Side

Pigtail
Leads

Terminal
Block

Same
Side

Suffix Number

Catalog Number

1

Left
Right➄

A01
A05

A02
A06

A03
A07

A04
A08

A1X5LPK
A1X5RPK

A1X5LTK
A1X5RTK➅

2

Left
Right➄

A09
A12

A10
A13

–
–

A11
A14

A2X5LPK
A2X5RPK

A2X5LTK
A2X5RTK➅

3

Left
Right➄

A18
A17

–
–

–
–

A15
A16

A3X5LPK
A3X5RPK

A3X5LTK
A3X5RTK➅

Instruction Leaflet/FRED Number 29C124

R-Frame
Electrical Rating Data➆➇
Maximum
Voltage

600
125
250

Frequency

50/60 Hz
Dc
Dc

Auxiliary Switch (RH only)
Maximum
Current Amperes

Number of
Contacts
(Make and Break)

Factory Mounted

6
0.50➂
0.25➂

Field Mounted

Connection Type and Location

Field Installation Kits➃

18-Inch Pigtail Leads

Pigtail Leads

Suffix Number➈

Catalog Number➈

2

A12

A2X6RPK

4

A19

A4X6RPK

Instruction Leaflet/FRED Number 29C125

➀ Endurance – 3000 electrical operations plus
1000 mechanical operations.
➁ Pigtail wire size – No. 18 AWG (0.82 mm2).
➂ Non-inductive load.
➃ Listed with Underwriters Laboratories, Inc.
for field installation under E64983.
➄ Standard mounting location – leads exit rear
of breaker.
➅ Not for use on 4-pole circuit breaker.
➆ Endurance: 500 electrical operations plus
2500 mechanical operations.
➇ Pigtail wire size: No. 18 AWG (0.82 mm2).
Leads are red, black and blue.
➈ A maximum of two auxiliary switches (any
combination of 2a/2b or 4a/4b plug-in modules may be installed in a circuit breaker.

PG.74A.01.T.E

Cutler-Hammer

Molded Case Circuit Breakers
Series C Internal Accessories

March 1999

145

Auxiliary Switch and Alarm Switch Combination

Auxiliary Switch and Alarm Switch Combination
General Information

a

Each catalog number listed in the
following table includes one auxiliary switch and one alarm switch.
In an auxiliary switch ASL switch

b

combination, the auxiliary switch is
always mounted on the side of the
plug-in module next to the center
pole of the circuit breaker.

Ordering Information
F-Frame
Electrical Rating Data➀➁
Maximum
Voltage

Frequency

50/60 Hz
50/60 Hz
Dc
Dc

125
600
125
250

Maximum
Current
Amperes

1
6
0.50➂
0.25➂

Auxiliary Switch and Alarm Switch Combination
Dielectric
Withstand
Voltage

Mounting
Location
(Pole)

2500
2500
2200
2200

Factory Mounted

Field Mounted

Connection Type and Location

Field Installation Kits➃

18-Inch Pigtail Leads

Terminal Block

Same Side

Same Side

Rear⑤

Suffix Number

Left➄
Right

Pigtail
Leads

Terminal
Block

Catalog Number

C01
C04

C02
C05

C03
C06

AAL1LPK
AAL1RPK

AAL1LTK
AAL1RTK➅

Instruction Leaflet/FRED Number 29C180

J-Frame
Auxiliary Switch and Alarm Switch Combination

Electrical Rating Data➆➁
Maximum
Voltage

Frequency

50/60 Hz
Dc
Dc

600
125
250

Maximum
Current
Amperes

6
0.50➂
0.25➂

Dielectric
Withstand
Voltage

2500

Number of
Sets of
Contacts
(1a and 1b
and
1M and 1B)

Mounting
Location
(Pole)

Factory Mounted

Field Mounted

Connection Type and Location

Field Installation Kits➇

18-Inch Pigtail Leads
Same
Side

Rear➈

Terminal
Block
Opposite
Side

Left
Right➈

Terminal
Block

Same
Side

Suffix Number

1

Pigtail
Leads

Catalog Number

C01
C04

C02
C05

–
–

C03
C06

AAL2LPK
AAL2RPK

AAL2LTK
AAL2RTK➅

Instruction Leaflet/FRED Number 29C181

K-Frame
Electrical Rating Data➁
Maximum
Voltage

Frequency

600
125
250

50/60 Hz
Dc
Dc

Maximum
Current
Amperes

6
0.50➂
0.25➂

Auxiliary Switch and Alarm Switch Combination
Dielectric
Withstand
Voltage

2500

Number of
Sets of
Contacts
(1a and 1b
and
1M and 1B)

Mounting
Location
(Pole)

Factory Mounted

Field Mounted

Connection Type and Location

Field Installation Kits➇

18-Inch Pigtail Leads
Same
Side

Rear➈

Terminal
Block
Opposite
Side

➀ Endurance: 6000 electrical operations plus
4000 mechanical operations.
➁ Pigtail wire size: No. 18 AWG (0.82 mm2).
➂ Non-inductive load.
➃ Not listed with Underwriters Laboratories,
Inc., for field installation.
➄ Standard mounting location.
➅ Not for use on 4-pole circuit breakers.

PG.74A.01.T.E

Left
Right➈

C01
C04

Terminal
Block

Same
Side

Suffix Number

1

Pigtail
Leads

Catalog Number

C02
C05

–
–

C03
C06

AAL3LPK
AAL3RPK

AAL3LTK
AAL3RTK

Instruction Leaflet/FRED Number 29C182

➆ Endurance – 6000 electrical operations plus
2000 mechanical operations.
➇ Listed with Underwriters Laboratories, Inc.
for field installation or interchangeable trip
unit breakers under E64983.

➈ Standard mounting location – leads exit rear
of breaker.
 Endurance – 5000 electrical operations plus
1000 mechanical operations.

146

Cutler-Hammer

Molded Case Circuit Breakers
Series C Internal Accessories

March 1999

Auxiliary Switch and Alarm Switch Combination

L- and M-Frames
Auxiliary Switch and Alarm Switch Combination

Electrical Rating Data➀➁
Maximum
Voltage

600
125
250

Frequency

50/60 Hz
Dc
Dc

Maximum
Current
Amperes

6
0.50➂
0.25➂

Dielectric
Withstand
Voltage

Number of
Sets of
Contacts

Mounting
Location
(Pole)

Factory Mounted

Field Mounted

Connection Type and Location

Field Installation Kits➃

18-Inch Pigtail Leads

2500

Same
Side

Terminal
Block

Rear➄

Opposite
Side

Pigtail
Leads

Terminal
Block

Same
Side

Suffix Number

Catalog Number

1A, 1B and
1 Make/
1 Break

Left
Right➄

C01
C04

C02
C05

–
–

C03
C06

AA114LPK
AA114RPK

AA114LTK
AA114RTK➅

2A, 2B and
1 Make/
1 Break

Left
Right➄

C07
C10

C08
C11

–
–

C12
C13

AA214LPK
AA214RPK

AA214LTK
AA214RTK➅

3A, 3B and
1 Make/
1 Break

Left
Right➄

C14
C15

–
–

–
–

–
–

AA314LPK
AA314RPK

–
–

Instruction Leaflet/FRED Number 29C183

N-Frame
Electrical Rating Data➆➁
Maximum
Voltage

600
125
250

Frequency

50/60 Hz
Dc
Dc

Maximum
Current
Amperes

6
0.50➂
0.25➂

Auxiliary Switch and Alarm Switch Combination
Dielectric
Withstand
Voltage

Number of
Sets of
Contacts

Mounting
Location
(Pole)

Factory Mounted

Field Mounted

Connection Type and Location

Field Installation Kits➃

18-Inch Pigtail Leads

2500

Same
Side

Rear➄

Terminal
Block
Opposite
Side

Pigtail
Leads

Terminal
Block

Same
Side

Suffix Number

Catalog Number

1A, 1B and
1 Make/
1 Break

Left
Right➄

C01
C04

C02
C05

–
–

C03
C06

AA115LPK
AA115RPK

AA115LTK
AA115RTK➅

2A, 2B and
1 Make/
1 Break

Left
Right➄

C07
C10

C08
C11

–
–

C12
C13

AA215LPK
AA215RPK

AA215LTK
AA215RTK➅

Instruction Leaflet/FRED Number 29C184

➀ Endurance – 5000 electrical operations plus
1000 mechanical operations.
➁ Pigtail wire size – No. 18 AWG (0.82 mm2).
➂ Non-inductive load.
➃ Listed with Underwriters Laboratories, Inc.
for field installation under E64983.
➄ Standard mounting location – leads exit rear
of breaker.
➅ Not for use on 4-pole circuit breaker.
➆ Endurance – 3000 electrical operations plus
1000 mechanical operations.

PG.74A.01.T.E

Cutler-Hammer

Molded Case Circuit Breakers
Series C Internal Accessories

March 1999

147

Shunt Trip

Shunt Trip
General Information
ST

a

The shunt trip provides remote controlled tripping of the circuit breaker.
The shunt trip consists of an intermittent rated solenoid with a tripping plunger and a cutoff switch
assembled to a plug-in module.

When required for ground fault protection applications, certain Ac rated
shunt trips, as noted in the Electrical
Rating Table, are suitable for operation at 55 percent of rated voltage.

Ordering Information
Select shunt trip catalog number
for the voltage within the indicated
voltage range. Shunt trip coils are
designed to be applied at specific
Ac or Dc voltages within the voltage
range shown. Electrical ratings are
also shown on applicable circuit
breaker accessory nameplates.

G-Frame

Shunt Trip (LH 3-Pole only)
Electrical Ratings
Volts

Catalog Number
Frequency

120
240
12
24
24

Suffix Number

Amperes

50/60 Hz
50/60 Hz
Dc
Dc
60 Hz

1.1
2.1
2.8
5.7
–

1373D62G01
1373D62G02
1373D62G15
1373D62G16
1373D62G20

S1
S2
S3
S4
S7

Instruction Leaflet/FRED Number 15550

Note: G-Frame circuit breakers are
factory sealed. Underwriters Laboratories, Inc., requires that internal
accessories be installed at the factory.
Internal accessories are UL listed for
factory installation under E7819.

PG.74A.01.T.E

Where local codes and standards
permit and UL listing is not required,
internal accessories can be field
installed. Accessory installation
should be done before the circuit
breaker is mounted and connected.

Cutler-Hammer

Molded Case Circuit Breakers
Series C Internal Accessories

148

March 1999

Shunt Trip

F-Frame
Electrical Rating Data➀➁➂

Shunt Trip

50/60 Hz

Dc

Supply Minimum VA
Voltage Operating
Voltage

Supply Minimum VA
Voltage Operating
Voltage

12
24

6.75

48
60
110
120
127

36

208
220
240
380

156

415
440
480
525
550
600

300

75
300

12
24

9

100
400

92
140
480
570
640

48
60

36

100
160

180
200
240
610

110
120
125
127

77

130
330
380
450
530
590
–

220
250
–
–
–
–
–

–
–
–
–
–
–
–

55
66
71
72
110
140
–
–
–
–
–

Voltage Rating
(Ac Frequency = 50/60 Hz)

Factory Mounted

Field Mounted

Connection Type and Location
18-Inch Pigtail Leads➄
Same
Side

Rear➅

Field Installation Kits➃
Terminal
Block

Opposite
Side

Pigtail
Leads

Terminal
Block

Same
Side

Suffix Number

Catalog Number

Left-Pole Mounting Ac/Dc Ratings
S01
S05
S09
S13

12-24 Vac or Vdc
48-127 Vac or 48-60 Vdc➆
208-380 Vac or 110-127 Vdc
415-600 Vac or 220-250 Vdc

S02
S06
S10
S14

S03
S07
S11
S15

S04
S08
S12
S16

SNT1LP03K
SNT1LP08K
SNT1LP12K
SNT1LP18K

SNT1LT03K
SNT1LT08K
SNT1LT12K
SNT1LT18K

S19
S23
S27
S31

S20
S24
S28
S32

SNT1RP03K
SNT1RP08K
SNT1RP12K
SNT1RP18K

SNT1RT03K➈
SNT1RT08K➈
SNT1RT12K➈
SNT1RT18K➈

Right- or Neutral-Pole Mounting Ac/Dc Ratings➇
S17
S21
S25
S29

12-24 Vac or Vdc
48-127 Vac or 48-60 Vdc➆
208-380 Vac or 110-127 Vdc
415-600 Vac or 220-250 Vdc

S18
S22
S26
S30

Instruction Leaflet/FRED Number 29C140

Note: F-Frame circuit breakers are
factory sealed. Underwriters Laboratories, Inc., requires that internal
accessories be installed at the factory.
Internal accessories are UL listed for
factory installation under E7819.

Where local codes and standards
permit and UL listing is not required,
internal accessories can be field
installed. Accessory installation
should be done before the circuit
breaker is mounted and connected.

J-Frame
Electrical Rating Data➀➁➉

Shunt Trip

50/60 Hz

Dc

Supply Minimum VA
Voltage Operating
Voltage

Supply Minimum VA
Voltage Operating
Voltage

12
24

9

31
173

12
24

8.4

50
247

48
60

36

686
1014

48
60

33.6

1094
1698

66
84
102
354
396
432

110
120
125
–
–
–

77

180
200
240
610

110
120
125
127

154

34
42
50
60

–
–
–
–

110
120
127
208
220
240

60.5

380
400
415
440

285

480
525
550
600

360

–
–

–
–
–
–

112
138
150
–
–
–
40
58
–
–
–
–
–
–

➀ Average unlatching time: 6 milliseconds.
➁ Average circuit breaker contact total opening time: 18 milliseconds.
➂ Endurance: 6000 electrical operations plus
4000 mechanical operations.
➃ Not listed with Underwriters Laboratories,
Inc., for field installation.
➄ Pigtail wire size: No. 18 AWG (0.82 mm2).
➅ Standard pigtail lead exit location.

Voltage Rating
(Ac Frequency = 50/60 Hz)

Factory Mounted

Field Mounted
Field Installation Kits

Connection Type and Location
18-Inch Pigtail Leads
Same
Side

Rear

Terminal
Block
Opposite
Side

Pigtail
Leads

Terminal
Block

Same
Side

Suffix Number

Catalog Number

Left-Pole Mounting Ac/Dc Ratings
12-24 Vac or Vdc
48-60 Vac or Vdc
110-240 Vac or 110-125 Vdc
380-440 Vac or 220-250 Vdc
480-600 Vac

S41
S49
S09
S33
S17

S42
S50
S10
S34
S18

S43
S51
S11
S35
S19

S44
S52
S12
S36
S20

SNT2P04K
SNT2P06K
SN2LP11K
SNT2P14K
SNT2P18K

SNT2T04K
SNT2T06K
SNT2T11K
SNT2T14K
SNT2T18K

S45
S53
S29
S33
S37

S46
S54
S30
S34
S38

S47
S55
S31
S35
S39

S48
S56
S32
S36
S40

SNT2P04K
SNT2P06K
SNT2P11K
SNT2P14K
SNT2P18K

SNT2T04K➈
SNT2T06K➈
SNT2T11K➈
SNT2T14K➈
SNT2T18K➈

Right-Pole Mounting Ac/Dc Ratings
12-24 Vac or Vdc
48-60 Vac or Vdc
110-240 Vac or 110-125 Vdc
380-440 Vac or 220-250 Vdc
480-600 Vac

Instruction Leaflet/FRED Number 29C142
➆ 120 Vac marked suitable for ground fault
protection devices.
➇ Standard mounting location.
➈ Not for use on 4-pole circuit breakers.
➉ Endurance – 6000 electrical operations plus
2000 mechanical operations.
 Supply voltages suitable for use with Class 1
GFP devices. Marking label included with
accessory kits.

 Listed with Underwiters Laboratories, Inc.

for field installation under E64983.
 Standard mounting location – leads exit rear

of breaker.
 Suitable for use with Class 1 ground fault

sensing element.

PG.74A.01.T.E

Cutler-Hammer

Molded Case Circuit Breakers
Series C Internal Accessories

March 1999

149

Shunt Trip

K-Frame
Shunt Trip

Electrical Rating Data➀➁➂
50/60 Hz

Dc

Supply Minimum VA
Voltage Operating
Voltage

Supply
Voltage

12
24
48
60
110➃
120➃
127➃
208➃
220➃
240➃

9

60

380
400
415
440

285

480
525
550
600

360

12
24
48
60

45
200
830
1280

Minimum
Operating
Voltage

8.4

100
120
140
420
470
550

110
120
125
–
–
–

77

95
108
120
136

220
250
–
–

154

40
50
50
70

–
–
–
–

–
–
–
–

–
–
–

VA

Voltage Rating
(Ac Frequency = 50/60 Hz)

Factory Mounted

Field Mounted

Connection Type and Location
18-Inch Pigtail Leads

35
170
710
1105
110
130
140
–
–
–
41
54
–
–
–
–
–
–

Same
Side

Rear➅

Field Installation Kits➄
Terminal
Block

Opposite
Side

Pigtail
Leads

Terminal
Block

Same
Side

Suffix Number

Catalog Number

Left-Pole Mounting Ac/Dc Ratings➅
S41
S49
S09
S13
S17

12-24 Vac or Vdc
48-60 Vac or Vdc
110-240 Vac or 110-125 Vdc➆
380-440 Vac or 220-250 Vdc
480-600 Vac

S42
S50
S10
S14
S18

S43
S51
S11
S15
S19

S44
S52
S12
S16
S20

SNT3P04K
SNT3P06K
SN3LP11K
SNT3P14K
SNT3P18K

SNT3T04K
SNT3T06K
SNT3T11K
SNT3T14K
SNT3T18K

S46
S30
S34
S38

S47
S31
S35
S39

S48
S32
S36
S40

SNT3P04K
SNT3P11K
SNT3P14K
SNT3P18K

SNT3T04K➈
SNT3T11K➈
SNT3T14K➈
SNT3T18K➈

Right-Pole Mounting Ac/Dc Ratings➇
S45
S29
S33
S37

12-24 Vac or Vdc
110-240 Vac or 110-125 Vdc➆
380-440 Vac or 220-250 Vdc
480-600 Vac

Instruction Leaflet/FRED Number 29C144

L- and M-Frames
Electrical Rating Data➀➁➂
50/60 Hz

Dc

Supply Minimum VA
Voltage Operating
Voltage

Supply
Voltage

Shunt Trip
Minimum
Operating
Voltage

VA

9

45
200

12
24

9

35
170

48
60

34

830
1280

48
60

34

710
1105

110➃
120➃
127➃
208➃
220➃
240➃

60

100
120
140
420
470
550

110
120
125
–
–
–

77

–
–

110
130
140
–
–
–

95
108
120
136

220
250
–
–

154
–
–
–

41
54
–
–

40
50
50
70

–
–
–
–

–
–
–
–

266

480
525
550
600

336

Factory Mounted

–
–
–
–

Same
Side

Rear➅

➀ Approximate unlatching time – 6 milliseconds.
➁ Approximate total circuit breaker contact
opening time – 18 milliseconds.
➂ Endurance – 5,000 electrical operations plus
1,000 mechanical operations.
➃ Supply voltages suitable for use with Class 1
GFP devices. Marking label included with
accessory kits.
➄ Listed with Underwriters Laboratories, Inc.,
for field installation under E64983.

Field Installation Kits➄
Terminal
Block

Opposite
Side

Pigtail
Leads

Terminal
Block

Same
Side

Suffix Number

Catalog Number

Left-Pole Mounting Ac/Dc Ratings➅
12-24 Vac or Vdc
48-60 Vac
48-60 Vdc
110-240 Vac
110-125 Vdc
380-440 Vac or 220-250 Vdc
480-600 Vac

S01
S05
S85
S09
S41
S13
S17

S02
S06
S86
S10
S42
S14
S18

S03
S07
S87
S11
S43
S15
S19

S04
S08
–
S12
S44
S16
S20

SNT4LP03K
SNT4LP05K
SNT4LP23K
SNT4LP11K
SNT4LP26K
SNT4LP14K
SNT4LP18K

SNT4LT03K
SNT4LT05K
SNT4LT23K
SNT4LT11K
SNT4LT26K
SNT4LT14K
SNT4LT18K

S22
S26
S89
S30
S46
S34
S38

S23
S27
S90
S31
S47
S35
S39

S24
S28
–
S32
S48
S36
S40

SNT4RP03K
SNT4RP05K
SNT4RP23K
SNT4RP11K
SNT4RP26K
SNT4RP14K
SNT4RP18K

SNT4RT03K
SNT4RT05K
SNT4RT23K
SNT4RT11K
SNT4RT26K
SNT4RT14K
SNT4RT18K

Right-Pole Mounting Ac/Dc Ratings➉
12-24 Vac or Vdc
48-60 Vac
48-60 Vdc
110-240 Vac
110-125 Vdc
380-440 Vac or 220-250 Vdc
480-600 Vac

S21
S25
S88
S29
S45
S33
S37

Instruction Leaflet/FRED Number 29C146

PG.74A.01.T.E

Field Mounted

Connection Type and Location
18-Inch Pigtail Leads

12
24

380
400
415
440

Voltage Rating
(Ac Frequency = 50/60 Hz)

➅ Standard mounting location – leads exit rear
of breaker.
➆ Suitable for use with Class 1 ground fault
sensing element.
➇ For use with KT (thermal-magnetic) trip units
only.
➈ Not for use on 4-pole circuit breaker.
➉ For use with LT (thermal-magnetic) 3-pole
trip units only.

Cutler-Hammer

Molded Case Circuit Breakers
Series C Internal Accessories

150

March 1999

Shunt Trip

N-Frame

Ordering Information

Electrical Rating Data➀➁➂

Shunt Trip

50/60 Hz

Dc

Supply Minimum VA
Voltage Operating
Voltage

Supply Minimum VA
Voltage Operating
Voltage

24

16.8

200

24

16.8

170

48
60

33.6

830
1280

48
60

33.6

710
1150

110➃
120➃
127➃
208➃
220➃
240➃

60

100
120
140
420
470
550

110
120
125
–
–
–

77
–
–
–

110
130
140
–
–
–

154
–
–
–

41
54
–
–

380
400
415
440

266

95
108
120
136

220
250
–
–

480
525
550
600

336

40
50
50
70

–
–
–
–

–
–
–
–

Voltage Rating
(Ac Frequency = 50/60 Hz)

Factory Mounted

Field Mounted

Connection Type and Location
18-Inch Pigtail Leads
Same
Side

Rear➅

Field Installation Kits➄
Terminal
Block

Opposite
Side

Pigtail
Leads

Terminal
Block

Same
Side

Suffix Number

Catalog Number

Left-Pole Mounting Ac/Dc Ratings➅
24 Vac or Vdc
48-60 Vac
110-240 Vac➃
110-125 Vdc
380-440 Vac or 220-250 Vdc
480-600 Vac
48-60 Vdc

S01
S05
S09
S41
S13
S17
S21

S02
S06
S10
S42
S14
S18
S22

S03
S07
S11
S43
S15
S19
S23

S04
S08
S12
S44
S16
S20
S24

SNT5LP03K
SNT5LP05K
SNT5LP11K
SNT5LP26K
SNT5LP14K
SNT5LP18K
SNT5LP23K

SNT5LT03K
SNT5LT05K
SNT5LT11K
SNT5LT26K
SNT5LT14K
SNT5LT18K
SNT5LT23K

Instruction Leaflet/FRED Number 29C148

–
–
–
–

➀ Approximate unlatching time – 6 milliseconds.
➁ Approximate total circuit breaker contact
opening time – 18 milliseconds.
➂ Endurance – 3000 electrical operations plus
1000 mechanical operations.
➃ Supply voltages suitable for use with Class 1
GFP devices. Marking label included with
accessory kits.
➄ Listed with Underwriters Laboratories, Inc.
for field installation under E64983.
➅ Standard mounting location – leads exit rear
of breaker.

PG.74A.01.T.E

Cutler-Hammer
March 1999

Molded Case Circuit Breakers
Series C Internal Accessories

151

Shunt Trip

R-Frame

Electrical Rating Data
Suffix
Number

03/03K

Application Ratings

Electrical Operating Ratings➀➁➂➃➄➅

Voltage (V) Frequency (Hz)

Supply
Minimum
Voltage (V) Operating
Voltage (V)

Ip (A)

Irms
at
0.250s
(A)

Irms
at
0.033s
(A)

VA

24

50/60

24

16.8

71.1

–

50.3

1210

1050

24

Dc

24

16.8

–

36.1

–

870

1050

48-60

50/60

48
60

34.0

13.1
17.2

–

9.2
12.2

450
740

1120

11/11K➆

110-240

50/60

110
120
127
208
220
240

60.5

4.2
4.5
4.6
7.9
8.5
8.7

–

3.0
3.2
3.3
5.6
6.0
6.1

330
390
430
1170
1370
1470

1480

14/14K

380-440

50/60

380
415
440

266.0

4.5
5.0
5.3

–

3.2
3.6
3.7

1220
1500
1640

1880

220-250

Dc

220
250

154.0

–

2.4
2.7

–

530
680

1500

18/18K

480-600

50/60

480
525
550
600

336.0

0.6
0.7
0.7
0.8

–

0.4
0.5
0.5
0.6

200
270
280
360

2200

23/23K

48-60

Dc

48
60

34.0

–

9.8
11.6

–

470
700

1120

26/26K

110-125

Dc

110
120
125

77.0

–

3.3
3.6
3.8

–

370
440
480

1250

05/05K

Shunt Trip (RH only)
Voltage Rating
(Ac Frequency = 50/60 Hz)

Factory Mounted

Field Mounted

Connection Type and Location

Field Installation Kits➇

18-Inch Pigtail Leads➈

Pigtail Leads

Suffix Number➈

Catalog Number➈

24 Vac or Vdc
48-60 Vac
110-240 Vac
380-440 Vac or 220-250 Vdc
480-600 Vac
48-60 Vdc
110-125 Vdc
Instruction Leaflet/FRED Number 29C150

➀ Approximate unlatching time of 6 milliseconds.
➁ Average circuit breaker contact total opening
time approximately 62 milliseconds, at rated
voltage.
➂ Endurance – 500 electrical operations and
2500 mechanical operations.
➃ Shunt trip can be operated up to a maximum
of six times per minute.
➄ Maximum operating voltage – 110% of
maximum voltage range rating.
➅ Pigtail wire size – No. 18 AWG (0.82 mm2).
Leads are yellow and white.
➆ Suitable for use with Class 1 GFP devices;
marking label supplied with accessory kit.
➇ Listed with Underwriters Laboratories, Inc.
for field installation under E64983.
➈ A maximum of two shunt trip plug-in modules may be installed in a circuit breaker.

PG.74A.01.T.E

One
Minute
Dielectric
Withstand
Voltage (V)

S21
S25
S29
S33
S37
S88
S45

SNT6P03K
SNT6P05K
SNT6P11K
SNT6P14K
SNT6P18K
SNT6P23K
SNT6P26K

Cutler-Hammer

Molded Case Circuit Breakers
Series C Internal Accessories

152

March 1999

Low Energy Shunt Trip

Low Energy Shunt Trip
ST
LE

General Information
microfarad capacitor charged to 28
Vdc is discharged through the shunt
trip coil, the resultant flux opposes
the permanent magnet flux field,
which releases the stored energy in
the spring to trip the circuit breaker.
As the circuit breaker resets, the
shunt trip reset arm is actuated by
the circuit breaker handle, resetting
the shunt trip. The plug-in module is
mounted in retaining slots in the top
of the trip unit. Coil is intermittentrated only. Cutoff provisions
required in control circuit.

Low energy shunt trip devices are
designed to operate from low
energy output signals from dedicated current sensors typically
applied in ground fault protection
schemes. However, with a proper
control voltage source, they may be
applied in place of conventional trip
devices for special applications. Flux
paths surrounding permanent magnets used in the shunt trip assembly
hold a charged spring poised in
readiness to operate the circuit
breaker trip mechanism. When a 100

Ordering Information
Select shunt trip catalog number
for the voltage within the indicated
voltage range. Shunt trip coils are
designed to be applied at specific
Ac or Dc voltages within the voltage
range shown. Electrical ratings are
also shown on applicable circuit
breaker accessory nameplates.

F-, J-, K-, L-, M-, N-, and R-Frames

Low Energy Shunt Trip➀
Mounting
Positions

Factory Mounted

Field Mounted

Connection Type and Location

Field Installation Kits➁

18-Inch Pigtail Leads
Same Side

Terminal Block

Rear➂

Opposite Side

Pigtail Leads

Terminal Block

Same Side

Suffix Numbers

Catalog Numbers

F-Frame
Left Pole
Right Pole➂

NO1
NO5

NO2
NO6

NO3
NO7

NO4
NO8

LST1LPK
LST1RPK

LST1LTK
LST1RTK

NO3
NO7

–
–

LST2LPK
LST2RPK

–
–

NO3
NO7

–
–

LST3LPK
LST3RPK

–
–

NO3
NO7

–
–

LST4LPK
LST4RPK

–
–

NO3

–

LST5LPK

–

–

–

LST6RPK

–

Instruction Leaflet/FRED Number 29C141

J-Frame
Left Pole➂
Right Pole

NO1
NO5

NO2
NO6

Instruction Leaflet/FRED Number 29C143

K-Frame
Left Pole➂
Right Pole➃

NO1
NO5

NO2
NO6

Instruction Leaflet/FRED Number 29C145

L- and M-Frames
Left Pole➂
Right Pole➃

NO1
NO5

NO2
NO6

Instruction Leaflet/FRED Number 29C147

N-Frame
➀ Cutoff provisions required in control circuit.
➁ Listed with Underwriters Laboratories, Inc.
for field installation under E64983.
➂ Standard mounting location – leads exit rear
of breaker.
➃ For use with thermal-magnetic trip units only.

Left Pole➂

NO1

NO2

Instruction Leaflet/FRED Number 29C149

R-Frame
Right Pole

NO1

–

Instruction Leaflet/FRED Number 29C151

PG.74A.01.T.E

Cutler-Hammer

Molded Case Circuit Breakers
Series C Internal Accessories

March 1999

153

Undervoltage Release Mechanism

Undervoltage Release
Mechanism
UV

General Information
The undervoltage release mechanism monitors a voltage (typically a
line voltage) and trips the circuit
breaker when the voltage falls to
between 70 and 35 percent of the
solenoid coil rating.
The undervoltage release mechanism consists of a continuous rated
solenoid with a plunger and tripping
lever mounted in a plug-in module.
The tab on the tripping lever resets
the undervoltage release mechanism

when normal voltage has been
restored and the circuit breaker
handle is moved to the reset (or OFF)
position. With less than pickup voltage applied to the undervoltage
release mechanism, the circuit
breaker contacts will not touch when
a closing operation is attempted.
Note: Undervoltage release mechanism accessories are not designed for,
and should not be used as, circuit
interlocks.

Ordering Information
Select handle reset undervoltage
release mechanism catalog number
for the voltage within the indicated
voltage range. Undervoltage release
mechanism coils are designed to be
applied at specific Ac or Dc voltages
within the voltage range shown.
Electrical ratings are shown on applicable circuit breaker accessory
nameplates.

G-Frame

Undervoltage Release Mechanism (LH 3-Pole only)
Style Numbers ➀➁➂

Electrical Ratings
Volts

120
24
48
60
110
208
220
240
380
415
440
480

Frequency

Factory Suffix

Amperes

50/60 Hz
50/60 Hz
50/60 Hz
50/60 Hz
50 Hz
60 Hz
50 Hz
50/60 Hz
50 Hz
50 Hz
50 Hz
60 Hz

0.05
0.22
0.11
0.10
0.049
0.026
0.025
0.024
0.015
0.013
0.012
0.01

1373D62G03
1373D62G04
1373D62G05
1373D62G06
1373D62G07
1373D62G08
1373D62G09
1373D62G10
1373D62G11
1373D62G12
1373D62G13
1373D62G14

T1
T2
T3
T4
T5
T6
T7
T8
T9
T10
T11
T12

Instruction Leaflet/FRED Number 15553

Note: G-frame circuit breakers are
factory sealed. Underwriters Laboratories, Inc., requires that internal
accessories be installed at the factory.
Internal accessories are UL listed for
factory installation under E7819.

➀ Includes 24 inch external pigtail leads, #18
AWG (16-.010).
➁ A maximum of two internal accessories may
be mounted in a three-pole circuit breaker.
➂ Suitable for mounting in left pole only of
3-pole breaker.

PG.74A.01.T.E

Where local codes and standards
permit and UL listing is not required,
internal accessories can be field
installed. Accessory installation
should be done before the circuit
breaker is mounted and connected.

154

Cutler-Hammer

Molded Case Circuit Breaker
Series C Internal Accessories

March 1999

Undervoltage Release Mechanism

F-Frame

Electrical Rating Data➀
50/60 Hz
Supply
Voltage

Dc
Dropout Voltage
Min.

12

Note: F-frame circuit breakers are
factory sealed. Underwriters Laboratories, Inc., requires that internal
accessories be installed at the factory.
Internal accessories are UL listed for
factory installation under E7819.
Where local codes and standards
permit and UL listing is not required,
internal accessories can be field
installed. Accessory installation
should be done before the circuit
breaker is mounted and connected.

Pickup
Voltage

Max.

4.2

6.3

VA

Supply
Voltage

Max.

Dropout Voltage
Min.

7.6

1.3
2.5

12

4.2

Pickup
Voltage

Max.

VA

Max.

8.4

10.2

2.8

24

8.4

16.8

20.4

1.4

24

8.4

16.8

20.4

1.6

48
60

21.0

33.6

40.8

1.2
1.9

48
60

21.0

33.6

40.8

1.3
2.0

110
120
127

44.5

77.0

93.5

1.3
1.5
1.7

110
120
125

44.5

77.0

93.5

1.5
1.7
1.9

208
220
240

84.0

145.6

176.8

2.2
2.4
2.9

220
250
–

87.5

154.0

187.0

–

–

–

2.6
3.4
–

380
415
440
480

168.0

266.0

323.0

2.9
3.5
3.9
4.6

–
–
–

–
–
–

–
–
–

–
–
–

–
–
–

525
550
600

210.0

367.0

446.0

4.3
4.8
5.8

–
–
–

–
–
–

–
–
–

–
–
–

–
–
–

Undervoltage Release Mechanism
Voltage Rating
Factory Mounted (For F-Frame Breaker and F-Frame HMCP)
(Ac Freq = 50/60 Hz)
Connection Type and Location
18-inch Pigtail Leads
Same Side

Field Mounted (F-Frame Breaker)
Terminal Block

Rear➂

Opposite Side

Field Mounted (F-Frame Breaker HMCP)

Field Installation Kits➁
Pigtail Leads

Terminal Block

Pigtail Leads

Terminal Block

Same Side

Suffix Numbers

Catalog Numbers

Left-Pole Mounting Ac Ratings
12 Vac
24 Vac
48 Vac
60 Vac
110-127 Vac
208-240 Vac
380-480 Vac
525-600 Vac

U01
U05
U37
U97
U13
U17
U21
U25

U02
U06
U38
U98
U14
U18
U22
U26

U03
U07
U39
U99
U15
U19
U23
U27

U04
U08
U40
U100
U16
U20
U24
U28

UVH1LP02K
UVH1LP03K
UVH1LP22K
UVH1LP24K
UVH1LP08K
UVH1LP11K
UVH1LP15K
UVH1LP18K

UVH1LT02K
UVH1LT03K
UVH1LT22K
UVH1LT24K
UVH1LT08K
UVH1LT11K
UVH1LT15K
UVH1LT18K

MUVH1LP02K
MUVH1LP03K
MUVH1LP22K
MUVH1LP24K
MUVH1LP08K
MUVH1LP11K
MUVH1LP15K
MUVH1LP18K

MUVH1LT02K
MUVH1LT03K
MUVH1LT22K
MUVH1LT24K
MUVH1LT08K
MUVH1LT11K
MUVH1LT15K
MUVH1LT18K

U50
U54
U86
U102
U62
U66
U70
U74

U51
U55
U87
U103
U63
U67
U71
U75

U52
U56
U88
U104
U64
U68
U72
U76

UVH1RP02K
UVH1RP03K
UVH1RP22K
UVH1RP24K
UVH1RP08K
UVH1RP11K
UVH1RP15K
UVH1RP18K

UVH1RT02K
UVH1RT03K
UVH1RT22K
UVH1RT24K
UVH1RT08K
UVH1RT11K
UVH1RT15K
UVH1RT18K

MUVH1RP02K
MUVH1RP03K
MUVH1RP22K
MUVH1RP24K
MUVH1RP08K
MUVH1RP11K
MUVH1RP15K
MUVH1RP18K

MUVH1RT02K
MUVH1RT03K
MUVH1RT22K
MUVH1RT24K
MUVH1RT08K
MUVH1RT11K
MUVH1RT15K
MUVH1RT18K

U30
U34
U38
U98
U42
U46

U31
U35
U39
U99
U43
U47

U32
U36
U40
U100
U44
U48

UVH1LP20K
UVH1LP21K
UVH1LP22K
UVH1LP24K
UVH1LP26K
UVH1LP28K

UVH1LT20K
UVH1LT21K
UVH1LT22K
UVH1LT24K
UVH1LT26K
UVH1LT28K

MUVH1LP20K
MUVH1LP21K
MUVH1LP22K
MUVH1LP24K
MUVH1LP26K
MUVH1LP28K

MUVH1LT20K
MUVH1LT21K
MUVH1LT22K
MUVH1LT24K
MUVH1LT26K
MUVH1LT28K

U78
U82
U86
U102
U90
U94

U79
U83
U87
U103
U91
U95

U80
U84
U88
U104
U92
U96

UVH1RP20K
UVH1RP21K
UVH1RP22K
UVH1RP22K
UVH1RP26K
UVH1RP28K

UVH1RT20K
UVH1RT21K
UVH1RT22K
UVH1RT22K
UVH1RT26K
UVH1RT28K

MUVH1RP20K
MUVH1RP21K
MUVH1RP22K
MUVH1RP22K
MUVH1RP26K
MUVH1RP28K

MUVH1RT20K
MUVH1RT21K
MUVH1RT22K
MUVH1RT22K
MUVH1RT26K
MUVH1RT28K

Right-Pole Mounting Ac Ratings➃➄
12 Vac
24 Vac
48 Vac
60 Vac
110-127 Vac
208-240 Vac
380-480 Vac
525-600 Vac

U49
U53
U85
U101
U61
U65
U69
U73

Left-Pole Mounting Dc Ratings
12 Vdc
24 Vdc
48 Vdc
60 Vdc
110-127 Vdc
220-250 Vdc

U29
U33
U37
U97
U41
U45

Right-Pole Mounting Dc Ratings➃➄
12 Vdc
24 Vdc
48 Vdc
60 Vdc
110-127 Vdc
220-250 Vdc

U77
U81
U85
U101
U89
U93

Instruction Leaflet/FRED Number 29C160 and 29C179 (HMCP)
➀ Endurance: 6000 electrical operations plus
4000 mechanical operations.

➁ Not listed with Underwriters Laboratories,
Inc., for field installation.
➂ Standard pigtail lead exit location.

➃ Standard mounting location.
➄ Not for use on right pole of 4-pole circuit
breaker.

PG.74A.01.T.E

Cutler-Hammer
March 1999

Molded Case Circuit Breakers
Series C Internal Accessories

155

Undervoltage Release Mechanism

J-Frame

Electrical Rating Data ➀➁
50/60 Hz
Supply
Voltage

Dc
Dropout Voltage

Pickup
Voltage

Min.

Max.

Max.

VA

Supply
Voltage

Dropout Voltage

Pickup
Voltage

Min.

Max.

Max.

VA

12

4.2

8.4

10.2

1.9

12

4.2

8.4

10.2

1.6

24

8.4

16.8

20.4

3.9

24

8.4

16.8

20.4

3.1

48
60

21.0

33.6

40.8

2.5
3.8

48
60

21.0

33.6

40.8

2.0
3.1

110
120
127

44.5

77.0

93.5

1.8
2.1
2.4

110
120
125

44.5

77.0

93.5

208
220
240

85.0

145.6

176.8

2.7
3.1
3.8

220
250
–

87.5

154.0

187.0

–

–

–

3.1
4.0
–

380
415
440
480

168.0

266.0

323.0

3.4
4.0
4.6
5.4

–
–
–

–
–
–

–
–
–

–
–
–

–
–
–

1.6
1.9
2.2

Undervoltage Release Mechanism
Voltage Rating
(Ac Freq =
50/60 Hz)

Factory Mounted

Field Mounted

Connection Type and Location

Field Installation Kits➂

18-inch Pigtail Leads
Same Side

Terminal
Block➁

Rear➂

Opposite Side

Pigtail Leads

Terminal
Block➃

Same Side

Suffix Numbers

Catalog Numbers

Left-Pole Mounting Ac Ratings➄
12 Vac
24 Vac
48-60 Vac
110-127 Vac
208-240 Vac
380-480 Vac

U05
U09
U13
U17
U21
U25

U06
U10
U14
U18
U22
U26

U07
U11
U15
U19
U23
U27

U08
U12
U16
U20
U24
U28

UVH2LP02K
UVH2LP03K
UVH2LP05K
UVH2LP08K
UVH2LP11K
UVH2LP15K

UVH2LT02K
UVH2LT03K
UVH2LT05K
UVH2LT08K
UVH2LT11K
UVH2LT15K

U38
U42
U46
U50
U54
U58

U39
U43
U47
U51
U55
U59

U40
U44
U48
U52
U56
U60

UVH2RP02K
UVH2RP03K
UVH2RP05K
UVH2RP08K
UVH2RP11K
UVH2RP15K

UVH2RT02K
UVH2RT03K
UVH2RT05K
UVH2RT08K
UVH2RT11K
UVH2RT15K

T02
T06
U10
T14
T18

T03
T07
T11
T15
T19

T04
T08
T12
T16
T20

UVH2LP20K
UVH2LP21K
UVH2LP23K
UVH2LP26K
UVH2LP28K

UVH2LT20K
UVH2LT21K
UVH2LT23K
UVH2LT26K
UVH2LT28K

T22
T26
T30
T34
T38

T23
T27
T31
T35
T39

T24
T28
T32
T36
T40

UVH2RP20K
UVH2RP21K
UVH2RP23K
UVH2RP26K
UVH2RP28K

UVH2RT20K
UVH2RT21K
UVH2RT23K
UVH2RT26K
UVH2RT28K

Right-Pole Mounting Ac Ratings➃
12 Vac
24 Vac
48-60 Vac
110-127 Vac
208-240 Vac
380-480 Vac

U37
U41
U45
U49
U53
U57

Left-Pole Mounting Dc Ratings➄
12 Vdc
24 Vdc
48-60 Vdc
110-127 Vdc
220-250 Vdc

T01
T05
T09
T13
T17

Right-Pole Mounting Dc Ratings➃
12 Vdc
24 Vdc
48-60 Vdc
110-127 Vdc
220-250 Vdc
➀ Endurance: 6000 electrical operations plus
2000 mechanical operations.
➁ For electrical rating data for manual, automatic and electrical reset undervoltage release mechanisms, refer to Cutler-Hammer.
➂ Listed with Underwriters Laboratories, Inc.
for field installation under E64983.
➃ Not for use on right pole of 4-pole circuit
breakers.
➄ Standard mounting location – leads exit rear
of breaker.

PG.74A.01.T.E

T21
T25
T29
T33
T37

Instruction Leaflet/FRED Number 29C163

156

Cutler-Hammer

Molded Case Circuit Breakers
Series C Internal Accessories

March 1999

Undervoltage Release Mechanism

K-Frame

Electrical Rating Data ➀
50/60 Hz
Supply
Voltage

Dc
Dropout Voltage

Pickup
Voltage

Min.

Max.

Max.

VA

Supply
Voltage

Dropout Voltage

Pickup
Voltage

Min.

Max.

Max.

VA

12

4.2

8.4

10.2

1.9

12

4.2

8.4

10.2

1.6

24

8.4

16.8

20.4

3.9

24

8.4

16.8

20.4

3.1

48
60

21.0

33.6

40.8

2.5
3.8

48
60

21.0

33.6

40.8

2.0
3.1

110
120
127

44.5

77.0

93.5

1.8
2.1
2.4

110
120
125

44.5

77.0

93.5

208
220
240

85.0

145.6

176.8

2.7
3.1
3.8

220
250
–

87.5

154.0

187.0

–

–

–

3.1
4.0
–

380
415
440
480

168.0

266.0

323.0

3.4
4.0
4.6
5.4

–
–
–

–
–
–

–
–
–

–
–
–

–
–
–

1.6
1.9
2.2

Undervoltage Release Mechanism
Voltage Rating
(Ac Freq =
50/60 Hz)

Factory Mounted

Field Mounted

Connection Type and Location

Field Installation Kits➁

18-inch Pigtail Leads
Same Side

Terminal Block

Rear➂

Opposite Side

Pigtail Leads

Terminal Block

Same Side

Suffix Numbers

Catalog Numbers

Left-Pole Mounting Ac Ratings➂
12 Vac
24 Vac
48-60 Vac
110-127 Vac
208-240 Vac
380-480 Vac

U05
U09
U13
U17
U21
U25

U06
U10
U14
U18
U22
U26

U07
U11
U15
U19
U23
U27

U08
U12
U16
U20
U24
U28

UVH3LP02K
UVH3LP03K
UVH3LP05K
UVH3LP08K
UVH3LP11K
UVH3LP15K

UVH3LT02K
UVH3LT03K
UVH3LT05K
UVH3LT08K
UVH3LT11K
UVH3LT15K

U38
U42
U46
U50
U54
U58

U39
U43
U47
U51
U55
U59

U40
U44
U48
U52
U56
U60

UVH3RP02K
UVH3RP03K
UVH3RP05K
UVH3RP08K
UVH3RP11K
UVH3RP15K

UVH3RT02K
UVH3RT03K
UVH3RT05K
UVH3RT08K
UVH3RT11K
UVH3RT15K

T02
T06
T10
T14
T18

T03
T07
T11
T15
T19

T04
T08
T12
T16
T20

UVH3LP20K
UVH3LP21K
UVH3LP23K
UVH3LP26K
UVH3LP28K

UVH3LT20K
UVH3LT21K
UVH3LT23K
UVH3LT26K
UVH3LT28K

T22
T26
T30
T34
T38

T23
T27
T31
T35
T39

T24
T28
T32
T36
T40

UVH3RP20K
UVH3RP21K
UVH3RP23K
UVH3RP26K
UVH3RP28K

UVH3RT20K
UVH3RT21K
UVH3RT23K
UVH3RT26K
UVH3RT28K

Right-Pole Mounting Ac Ratings➃➄
12 Vac
24 Vac
48-60 Vac
110-127 Vac
208-240 Vac
380-480 Vac

U37
U41
U45
U49
U53
U57

Left-Pole Mounting Dc Ratings➂
12 Vdc
24 Vdc
48-60 Vdc
110-127 Vdc
220-250 Vdc

T01
T05
T09
T13
T17

Right-Pole Mounting Dc Ratings➃➄
12 Vdc
24 Vdc
48-60 Vdc
110-127 Vdc
220-250 Vdc

T21
T25
T29
T33
T37

Instruction Leaflet/FRED Number 29C166
➀ Endurance: 5,000 electrical operations plus
1,000 mechanical operations
➁ Listed with Underwriters Laboratories, Inc.,
for field installation under E64983.
➂ Standard mounting location — leads exit
rear of breaker.
➃ For use with KT (thermal-magnetic) trip units
only.
➄ Not for use on right pole of 4-pole circuit
breaker.

PG.74A.01.T.E

Cutler-Hammer
March 1999

Molded Case Circuit Breakers
Series C Internal Accessories

157

Undervoltage Release Mechanism

L- and M-Frames

Electrical Rating Data ➀
50/60 Hz
Supply
Voltage

Dc
Dropout Voltage

Pickup
Voltage

Min.

Max.

Max.

VA

Supply
Voltage

Dropout Voltage

Pickup
Voltage

Min.

Max.

Max.

VA

12

4.2

8.4

10.2

1.9

12

4.2

8.4

10.2

1.6

24

8.4

16.8

20.4

3.9

24

8.4

16.8

20.4

3.1

48
60

21.0

33.6

40.8

2.5
3.8

48
60

21.0

33.6

40.8

2.0
3.1

110
120
127

44.5

77.0

93.5

1.8
2.1
2.4

110
120
125

44.5

77.0

93.5

208
220
240

85.0

145.6

176.8

2.7
3.1
3.8

220
250
–

87.5

154.0

187.0

–

–

–

3.1
4.0
–

380
415
440
480

168.0

266.0

323.0

3.4
4.0
4.6
5.4

–
–
–

–
–
–

–
–
–

–
–
–

–
–
–

1.6
1.9
2.2

Undervoltage Release Mechanism
Voltage Rating
(Ac Freq =
50/60 Hz)

Factory Mounted

Field Mounted

Connection Type and Location

Field Installation Kits➁

18-inch Pigtail Leads
Same Side

Terminal Block

Rear➂

Opposite Side

Pigtail Leads

Terminal Block

Same Side

Suffix Numbers

Catalog Numbers

Left-Pole Mounting Ac Ratings➂
12 Vac
24 Vac
48-60 Vac
110-127 Vac
208-240 Vac
380-480 Vac

U05
U09
U13
U17
U21
U25

U06
U10
U14
U18
U22
U26

U07
U11
U15
U19
U23
U27

U08
U12
U16
U20
U24
U28

UVH4LP02K
UVH4LP03K
UVH4LP05K
UVH4LP08K
UVH4LP11K
UVH4LP15K

UVH4LT02K
UVH4LT03K
UVH4LT05K
UVH4LT08K
UVH4LT11K
UVH4LT15K

U38
U42
U46
U50
U54
U58

U39
U43
U47
U51
U55
U59

U40
U44
U48
U52
U56
U60

UVH4RP02K
UVH4RP03K
UVH4RP05K
UVH4RP08K
UVH4RP11K
UVH4RP15K

UVH4RT02K
UVH4RT03K
UVH4RT05K
UVH4RT08K
UVH4RT11K
UVH4RT15K

T02
T06
T10
T14
T18

T03
T07
T11
T15
T19

T04
T08
T12
T16
T20

UVH4LP20K
UVH4LP21K
UVH4LP23K
UVH4LP26K
UVH4LP28K

UVH4LT20K
UVH4LT21K
UVH4LT23K
UVH4LT26K
UVH4LT28K

T22
T26
T30
T34
T38

T23
T27
T31
T35
T39

T24
T28
T32
T36
T40

UVH4RP20K
UVH4RP21K
UVH4RP23K
UVH4RP26K
UVH4RP28K

UVH4RT20K
UVH4RT21K
UVH4RT23K
UVH4RT26K
UVH4RT28K

Right-Pole Mounting Ac Ratings➃➄
12 Vac
24 Vac
48-60 Vac
110-127 Vac
208-240 Vac
380-480 Vac

U37
U41
U45
U49
U53
U57

Left-Pole Mounting Dc Ratings➂
12 Vdc
24 Vdc
48-60 Vdc
110-127 Vdc
220-250 Vdc

T01
T05
T09
T13
T17

Right-Pole Mounting Dc Ratings➃➄
12 Vdc
24 Vdc
48-60 Vdc
110-127 Vdc
220-250 Vdc

T21
T25
T29
T33
T37

Instruction Leaflet/FRED Number 29C170
➀ Endurance: 5000 electrical operations plus
1000 mechanical operations
➁ Listed with Underwriters Laboratories, Inc.
for field installation under E64983.
➂ Standard mounting location — leads exit
rear of breaker.
➃ For use with LT (thermal-magnetic) trip units
only.
➄ Not for use on right pole of 4-pole circuit
breaker.

PG.74A.01.T.E

158

Cutler-Hammer

Molded Case Circuit Breakers
Series C Internal Accessories

March 1999

Undervoltage Release Mechanism

N-Frame

Electrical Rating Data ➀
50/60 Hz
Supply
Voltage

Dc
Dropout Voltage

Pickup
Voltage

Min.

Max.

Max.

VA

Supply
Voltage

Dropout Voltage

Pickup
Voltage

Min.

Max.

Max.

VA

12

4.2

8.4

10.2

1.9

12

4.2

8.4

10.2

1.6

24

8.4

16.8

20.4

3.9

24

8.4

16.8

20.4

3.1

48
60

21.0

33.6

40.8

2.5
3.8

48
60

21.0

33.6

40.8

2.0
3.1

110
120
127

44.5

77.0

93.5

1.8
2.1
2.4

110
120
125

44.5

77.0

93.5

1.6
1.9
2.2

208
220
240

84.0

145.6

176.8

2.7
3.1
3.8

220

87.5

154.0

187.0

3.1

250

–

–

–

4.0

380
415
480
500

175.0

266.0

323.0

3.4
4.0
4.6
5.4

–
–
–

–
–
–

–
–
–

–
–
–

–
–
–

Undervoltage Release Mechanism
Voltage Rating
(Ac Freq =
50/60 Hz)

Factory Mounted

Field Mounted

Connection Type and Location

Field Installation Kits➁

18-inch Pigtail Leads
Same Side

Terminal Block

Rear➂

Opposite Side

Pigtail Leads

Terminal Block

Same Side

Suffix Numbers

Catalog Numbers

Left-Pole Mounting Ac Ratings➂
12 Vac
24 Vac
48-60 Vac
110-127 Vac
208-240 Vac
380-480 Vac

U05
U09
U13
U17
U21
U25

U06
U10
U14
U18
U22
U26

U07
U11
U153
U19
U23
U27

U08
U12
U16
U20
U24
U28

UVH5LP02K
UVH5LP03K
UVH5LP05K
UVH5LP08K
UVH5LP11K
UVH5LP29K

UVH5LT02K
UVH5LT03K
UVH5LT05K
UVH5LT08K
UVH5LT11K
UVH5LT29K

T02
T06
T10
T14
T18

T03
T07
T11
T15
T19

T04
T08
T12
T16
T20

UVH5LP20K
UVH5LP21K
UVH5LP23K
UVH5LP26K
UVH5LP28K

UVH5LT20K
UVH5LT21K
UVH5LT23K
UVH5LT26K
UVH5LT28K

Left-Pole Mounting Dc Ratings➂
12 Vdc
24 Vdc
48-60 Vdc
110-127 Vdc
220-250 Vdc

T01
T05
T09
T13
T17

Instruction Leaflet/FRED Number 29C174

➀ Endurance: 3000 electrical operations plus
1000 mechanical operations.
➂ Listed with Underwriters Laboratories, Inc.
for field installation under E64983.
➂ Standard mounting location – leads exit rear
of breaker.

PG.74A.01.T.E

Cutler-Hammer
March 1999

Molded Case Circuit Breakers
Series C Internal Accessories

159

Undervoltage Release Mechanism

R-Frame

Ac Undervoltage Release Mechanism (Handle Reset) Ratings➀➁
Catalog Application Electrical Operating Ratings
Suffix
Ratings
Voltage
(V)

Approximate Operating Time (ms)

Supply Dropout Voltage (V) Pickup VA
Voltage
Voltage
Min.
Max.
(V) Max.
(V)

Initiation➃ Maximum Dielectric➄
Min.➂
Withstand
Circuit
Circuit
UVR
Voltage (V)
Breaker
Response Breaker
Contact
Contact
Separation Opening

02/02K

12

12

4.2

8.4

10.2

2.3

5

46

77

1024

03/03K

24

24

8.4

16.8

20.4

3.1

5

46

77

1048

05/05K

48-60

48
60

21.0

33.5

40.8

3.4
6.0

5

46

77

1120

08/08K

110-127

110
120
127

44.5

77.0

93.5

3.3
3.6
3.8

5

46

77

1254

11/11K

208-240

208
220
240

84.0

145.6

176.8

4.2
6.6
7.2

5

46

77

1480

29/29K

380-500

380
415
440
480
500

168.0

266.0

323.0

3.8
8.3
8.8
9.6
10.0

5

46

77

2000

Dc Undervoltage Release Mechanism (Handle Reset) Ratings➀➁
Catalog Application Electrical Operating Ratings
Suffix
Ratings
Voltage
(V)

Approximate Operating Time (ms)

Supply Dropout Voltage (V) Pickup VA
Voltage
Voltage
Min.
Max.
(V)
(V) Max.

Initiation➃ Maximum Dielectric➄
Min.➂
Withstand
Circuit
Circuit
UVR
Voltage (V)
Breaker
Response Breaker
Contact
Contact
Separation Opening

20/20K

12

12

4.2

8.4

10.2

3.4

5

46

77

21/21K

24

24

8.4

16.8

20.4

4.3

5

46

77

1048

23/23K

48-60

48
60

21.0

33.5

40.8

4.8
7.2

5

46

77

1120

26/26K

110-127

110
120
125

43.8

77.0

93.5

3.3
3.6
3.8

5

46

77

1250

28/28K

220-250

220
250

87.5

154.0

187.0

6.6
7.5

5

46

77

1500

Undervoltage Release Mechanism (RH only)
Voltage Rating
(Ac Freq = 50/60 Hz)

➀ Endurance – 500 electrical operations plus
2500 mechanical operations.
➁ Pigtail wire size – No. 18 AWG (0.82 mm2).
Leads are orange and brown.
➂ UVR will override a momentary voltage dip
up to the response time shown.
➃ Unlatching occurs 1 millisecond before
circuit breaker contacts begin to separate.
➄ For 1 minute.

PG.74A.01.T.E

Factory Mounted

Field Mounted

Connection Type and Location

Field Installation Kits➀

18-inch Pigtail Leads

Pigtail Leads

Suffix Numbers➁

Catalog Numbers➁

12 Vac
24 Vac
48-60 Vac
110-127 Vac
208-240 Vac
380-500 Vac
12 Vdc
24 Vdc
48-60 Vdc
110-125 Vdc
220-250 Vdc
Instruction Leaflet/FRED Number 29C178

U37
U41
U45
U49
U53
U57
T21
T25
T29
T33
T37

UVH6RP02K
UVH6RP03K
UVH6RP05K
UVH6RP08K
UVH6RP11K
UVH6RP29K
UVH6RP20K
UVH6RP21K
UVH6RP23K
UVH6RP26K
UVH6RP28K

1024

160

Cutler-Hammer

Molded Case Circuit Breakers
Series C Internal Accessories

March 1999

Accessory Terminal Block/Cutler-Hammer PowerNet Communications Kit (OPTIM 550 only)

Accessory Terminal Block
(R-Frame)

Number of Control Wires For Each Internally Mounted Accessories
Type of Accessory

Number of Contacts Per Single
Accessory

(For Fixed Mounted Configuration)

Required Number of Wires

Auxiliary Switch

2a/2b
4a/4b

6
12

Alarm (Signal)/
Lockout Switch

1m/1b
2m/2b

6
12

Shunt Trip

N/A

2

Low Energy Shunt

N/A

2

Undervoltage Release Mechanism

N/A

2

Ordering Information➀

General Information
Internal accessory wiring leads are
normally supplied with pigtail leads
(No. 18 AWG) that exit from the right
side of the circuit breaker. Where
specified, fixed mounted accessory
terminal blocks are available. A maximum of one 24-point terminal block
can be installed on the right side of
the circuit breaker for the internal
accessories.

Factory Installed

Field Mounted

Suffix Number

Catalog Number

Q01

TBRDK

Instruction Leaflet/FRED Number 29C312

For convenience in determining the
appropriate number of terminal
block points required, refer to table
at right.

Cutler-Hammer PowerNet Communications Kit (OPTIM 550 only) K-, L-, and N-Frames
General Information

Ordering Information

The Cutler-Hammer PowerNet
Communications Kit can be ordered
to add Cutler-Hammer PowerNet
communications to an existing
OPTIM 550 breaker in the field. An
18-inch wiring pigtail is routed to the
rear of the breaker: two wires for
Cutler-Hammer PowerNet and two
wires for 24V Dc (45 mA load). It is
recommended that the power supply
be an “isolated high quality” unit.

Cutler-Hammer PowerNet
Communications Kit
Circuit Breaker

K-Frame
L-Frame
N-Frame

Catalog Numbers

ICK550K
ICK550L
ICK550N

Instruction Leaflet/FRED Number 29C506,
29C897, 29C898

➀ One 24-point accessory terminal block
provided with circuit breaker when ordered
factory installed or shipped from warehouse
as separate item when ordered for field
installation. See Digitrip RMS master connection diagram (IL 29C714).

PG.74A.01.T.E

Cutler-Hammer

Molded Case Circuit Breakers
Series C External Accessories

March 1999

161

Termination Hardware – Ring Type

Endcap Kit

Keeper Nut

Plug Nut

The keeper nut slides onto the line
or load conductor of the circuit
breaker and acts as a threaded
adapter for the conductor to accept
a ring terminal or other bolt-on connector. The keeper nut is available
with English and metric thread sizes.
Screws and washers are supplied by
customer. (Field installation only.)
Listed per UL File E7819.

J-Frame

Ordering Information
The endcap kit slides onto the line or
load conductor of the circuit breaker
and acts as a threaded adapter for
the conductor to accept a ring terminal or other bolt-on connector. The
endcap kit is available with English
and metric thread sizes. Screws and
washers are supplied by customer.
(Field installation only.) Listed per
UL File E7819.

Thread Size

Thread Type

Thread Size

Catalog Number
Package of 12
(Priced Individually)

Ordering Information
Thread Type

The plug nut is used in applications
where screw-connected ring-type
terminals are preferred to connect
cables to circuit breaker conductors.
The plug nut is press-fit into the
opening in the circuit breaker terminal conductor. Screws and washers
are supplied by customer.

F-Frame

Catalog Number

Imperial
Metric

10-32
M-5

KPR1A
KPR1AM

Package of 12
(Priced Individually)

F-Frame
Imperial
Metric

10-32
M-5

KPEK1
KPEK1M

10-32
M-5

KPEK2
KPEK2M

10-32
M-5

KPEK3
KPEK3M

J-Frame
Imperial
Metric
K-Frame
Imperial
Metric

Thread
Type

L-Frame
Imperial
Metric

K-Frame

10-32
M-5

KPEK4
KPEK4M

Imperial
Metric

Thread
Size

Line/
Load End

Catalog
Number
Package of 3

.375-16

Line
Load

KPR3A
KPR3B

M-8

Line
Load

KPR3AM
KPR3BM

L-, M-, N-Frames
Not required. Terminals are threaded.

PG.74A.01.T.E

Ordering Information
Thread
Type

Imperial
Metric

Thread
Size

.250-20
M-6

Catalog Number
Package of 6

PLN2
PLN2M

162

Cutler-Hammer

Molded Case Circuit Breakers
Series C External Accessories

March 1999

Termination Hardware – Control and Multi-Wire

Control Wire Terminal Kit

Multi-Wire Connectors
J- and K-Frames

F-Frame

Not for use with T250KB terminals.

The control wire terminal kit provides a means to tap off control
power from a main disconnect using
the provided male end of a quick
disconnect.
For use with steel or stainless steel➀
terminals only.

Ordering Information
Package of 12 control wire terminal
tangs. Terminals must be ordered
separately. Priced individually.
Catalog Number

KCWTK

Ordering Information
Package of 12 control wire terminal
tangs. Terminals must be ordered
separately. Priced individually.
Catalog Number

FCWTK

L-Frame
AWG Wire
Range/Number
Conductors

Metric
Catalog
Wire
Number
2
Range mm

Field-installed multi-wire connectors for the load side (OFF) end terminals. They are used to distribute
the load from the circuit breaker to
multiple devices without the use of
separate distribution terminal
blocks.
Multi-wire lug kits include mounting
hardware, insulators and tin-plated
aluminum connectors to replace
three mechanical load lugs. UL
listed for copper only as used on the
load side (OFF) end.

Ordering Information
Package of 3.

Al/Cu
(2) 250 – 350 kcmil

120-150

TA602LDCW➁

Cu
(2) 3/0 – 350 kcmil

120-150

T602LDCW➁

Al/Cu
(2) 400 – 500 kcmil

185-240

2TA603LDCW➀
2-Pole Kit

Al/Cu
(2) 400 – 500 kcmil

185-240

3TA603LDCW➀
3-Pole Kit

225

3

#14-2

3TA150F3K

Al/Cu
(2) 400 – 500 kcmil

185-240

4TA603LDCW➀
4-Pole Kit

225

6

#14-6

3TA150F6K

J-Frame
225

3

#14-2

3TA250J3K

225

6

#14-6

3TA250J6K

400

3

#12-2/0

3TA400K3K

400

6

#14-2/0

3TA400K6K

Maximum
Amperes

Wires
Per
Terminal

Wire
Size
Range
AWG
Cu

Kit
Catalog
Number

F-Frame

K-Frame

➀ Terminal kits contain one terminal for each
pole and one terminal cover.
➁ Individually packed.

PG.74A.01.T.E

Cutler-Hammer

Molded Case Circuit Breakers
Series C External Accessories

March 1999

163

Base Mounting Hardware

Base Mounting Hardware

Number Description
of
Poles

Ordering Information
Hardware for surface mounting of
circuit breakers is supplied only on
request. Hardware consists of
mounting screws and lockwashers.
Order hardware for circuit breaker
pole configurations as required.
Screw Length

Imperial Thread

Style Number

Style /
Catalog
Number

Number Description
of
Poles

Type of
Mounting

Style /
Catalog
Number

F-Frame
1

.164-32 x 3.188
inch PanHead Steel
Screws,
Lockwashers,
and Clamps

Individual 624B375G01
624B375G02
Group
(one set of
hardware
for two
circuit
breakers)

1

M4 - 0.7 x
80 mm PanHead Steel
Screws,
Lockwashers,
and Clamps

Individual 4218B80G09
4218B80G10
Group
(one set of
hardware
for
two circuit
breakers)

2

.164-32 x 1.5
inch PanHead
Steel Screws
and Lockwashers

Individual

4218B80G01

2

M4 - 0.7 x
38 mm PanHead Steel
Screws and
Lockwashers

Individual

4218B80G11

3, 4

.164-32 x 1.5
inch PanHead
Steel Screws
and Lockwashers

Individual

BMH1

3, 4

M4 - 0.7 x
38 mm PanHead Steel
Screws and
Lockwashers

Individual

BMH1M

0.250-20 x 2.75 Individual
inch PanHead Steel
Screws and
Lockwashers

BMH2

2, 3, 4

M6 – 0.7 x
70mm PanHead Steel
Screws and
Lockwashers

Individual

BMH2M

0.250-20 x 1.5
inch PanHead Steel
Screws and
Lockwashers

Individual

BMH3

2, 3, 4

M6 – 0.7 x
38mm PanHead Steel
Screws and
Lockwashers

Individual

BMH3M

0.250-20 x 1.5
inch FilisterHead Steel
Screws and
Lockwashers
and Flat
Washers

Individual

BMH4

2, 3

–

Individual

BMH4M

0.3125-18 x
1.25 inch
Filster-Head
Steel Screws
and
Lockwashers
and Flat
Washers

Individual

BMH5

2, 3

–

Individual

BMH5M

BMH5

2, 3

–

Individual

BMH5M

G-Frame
2.625 (66.7 mm)
3.000 (76.2 mm)

Metric Thread
Type of
Mounting

624B375G23
8703C80G05

J-Frame
2, 3, 4

K-Frame
2, 3, 4

L-Frame
2, 3, 4

M-Frame
2, 3

N-Frame
2, 3, 4

0.3125-18 x
1.25 inch
Pan-Head
Steel Screws
and Lockwashers

R-Frame
Supplied by customer

PG.74A.01.T.E

Cutler-Hammer

Molded Case Circuit Breakers
Series C External Accessories

164

March 1999

Drawout Cassette

Drawout Cassette
Ordering Information
RD Drawout Cassette
100 kA/480 Vac version

RD Drawout Cassette
65 kA/480 Vac version
Description

Catalog Number

Catalog Number

Movable
Mechanism

RD20DOM

Movable
Mechanism

RD20DOM

Stationary
Mechanism

RD20DOS
(without shutters)
RD20DOSS
(with shutters)

Stationary
Mechanism

RD20DOS
(without shutters)
RD20DOSS
(with shutters)

Instruction Leaflet/FRED Number 32697

The drawout cassette is currently for
use with the standard 3-pole 65 kA/
480 Vac, 1600A and 2000A RD circuit
breakers only. It consists of two
separate components: the movable
mechanism which is factory
mounted to the circuit breaker frame
(shown in figure) and the stationary
mechanism which is housed in the
cassette and shipped separately.

Description

Instruction Leaflet/FRED Number 32697

Note: Movable mechanism must
be ordered with RD or RDC circuit
breaker and is shipped mounted to
circuit breaker frame. Stationary
mechanism is ordered separately.
All internal accessories must be factory installed for use with drawout.

The drawout mechanism has four
positions.
■

■

■

■

Connected – The breaker is fully
connected to the primary stabs
and secondary contacts.
Test – The breaker is not connected to the primary stab but
is connected to the secondary
contacts.
Disconnected – Both the primary
stabs and the secondary contacts
are disconnected.
Withdraw – The breaker can be
removed from the cassette.

PG.74A.01.T.E

Cutler-Hammer

Molded Case Circuit Breakers
Series C External Accessories

March 1999

165

Termination Hardware – Protective Shields

Terminal Shields
Terminal shields provide protection
against accidental contact with live
line side terminations. Terminal
shields are fabricated from high
dielectric insulating material and
fasten over the front terminal access
openings. Small openings in the
shields provide limited access to the
terminals for tightening connectors.
(Field installation only.)

Ordering Information
J-Frame

G-Frame

L-Frame

Terminal Shield
Number Units in Package

Style Number

10

GTSK3

Number of Poles

F-Frame

Line

PG.74A.01.T.E

Style Number
(Package of 10)

2, 3
4

Line End

1266C07G01
6631C01G01

2, 3
4

Load End

6641C16G01
6641C16G02

K-Frame

Number Location Style Number
of Poles
Special - For
Standard
use when
(Package of 10)
(Priced Individually) electrical
operator is
mounted on
circuit
breaker

1
2
3
4

Location

625B229G06
625B229G07
625B229G08
625B229G09

–
–
4210B95G01
4210B95G02

Number of Poles

Style Number (Package of 1)

314CA420G01

M-Frame

Location

Catalog Number
(Package of 10)

Style Number (Package of 1)

4203B20G01
2, 3

Line

TS33LN

4

Line

TS34LN

3

Load

TS33LD

166

Cutler-Hammer

Molded Case Circuit Breakers
Series C External Accessories

March 1999

Termination Hardware

Terminal End Covers

Interphase Barriers

F-Frame

The interphase barriers provide
additional electrical clearance
between circuit breaker poles for
special termination applications.
The barriers are high dielectric insulating plates that are installed in the
molded slots between the terminals.
(Field installation only.) Two per
package.

The terminal end covers are
designed for use in motor control
center applications where, because
of confined spaces, line side conductors are normally custom fitted. The
molded end covers are made of high
dielectric glass-polyester and slide
over the line ends of the circuit
breaker. Close fitting conductor
openings are molded into the end
covers. The end cover and circuit
breaker case fit together to form
terminal compartments that isolate
discharged ionizing gases during circuit breaker tripping. Terminal end
covers are available with two conductor opening diameters, 0.25 and
0.41 inch, and are listed per UL File
E7819. (Field installation only.)

Frame

Catalog Number

F

IPB1

J

IPB2

K

IPB3

L

IPB4

M

IPB4

N

IPB5

Ordering Information
The terminal end cover is available
for 3-pole circuit breakers only. Two
conductor opening sizes are available. Specify quantity (one per
circuit breaker) when ordering.
Conductor Opening Diameter (Inches)

0.25 (6.35 mm)
0.41 (10.41 mm)

Catalog Number

TEC1
TEC2

PG.74A.01.T.E

Cutler-Hammer

Molded Case Circuit Breakers
Series C External Accessories

March 1999

167

Base Mounting Adapters

Base Mounting Plate➀
G-Frame GD/GC/GHC

DIN Rail Adapter➁➂
G-Frame GD/GC/GHC

Key Operated Attachment
G-Frame GD/GC/GHC

Ordering Information
Number Units in Package

Ordering Information
Number Units in Package

1

10
10

Style Number

207B513G01

➀ Suitable for mounting (6) single-pole circuit
breakers.
➁ For use with standard 35 mm DIN Rail such
as, 35 x 7.5 or 35 x 15 mm per DIN EN50022.
➂ Adapter mounting screws included are for
use with 2- and 3-pole circuit breakers.
Adapters for 1-pole circuit breakers clip into
the base molding.
➃ For use on 3-pole breakers only.

PG.74A.01.T.E

Style Number

1225C79G01
1225C79G02➃

Instruction Leaflet/FRED Number 29C091

Ordering Information
Number Units in Package

10

Style Number

GK0A

Instruction Leaflet/FRED Number 29C090

168

Cutler-Hammer

Molded Case Circuit Breakers
Series C External Accessories

March 1999

Handle Locking and Blocking Devices

Lock Dog (non-padlockable)
G-Frame GD/GC/GHC/GB/
GHB/GMCP

Ordering Information

Ordering Information
Number Units in Package

Style Number

1

Padlockable Handle
G-Frame GD/GC/GHC/GB/GHB

Number Units in Package

Style Number

10

1294C01H01

1223C77G03

(Accepts .285 Lock Shank)

Non-Padlockable
Handle Block

Padlockable Handle Block

Snap-On Padlockable
Handle Lock Hasp

The snap-on padlockable handle
lock allows the handle to be locked
in the OFF or ON position. (Trip-free
operation allows the circuit breaker
to trip when the handle lock holds
the circuit breaker handle in the ON
position.) This device was designed
for use on the 1-pole circuit breaker,
but may be used on 1-, 2-, 3-, and
4-pole styles. The handle lock snaps
onto the escutcheon area of the handle with an optional retaining screw
for added secureness. The handle
lock will accommodate one padlock
with a 1/4-inch (6 mm) shackle.
Listed per UL File E7819. (Field
installation only.)

Ordering Information
Frame

The nonlockable handle block
secures the circuit breaker handle
in either the ON or OFF position.
(Trip-free operation allows the circuit breaker to trip when the handle
block holds the circuit breaker handle in the ON position.) The device is
positioned over the circuit breaker
handle and secured by a setscrew to
deter accidental operation of the
circuit breaker handle. Listed per UL
File E7819. (Field installation only.)

The device is positioned in the
cover opening to prevent handle
movement. Will accommodate one
5/16 padlock.

Catalog Number

F

PHB1

Ordering Information
Frame

Catalog Number

J, K

PHB3

Ordering Information
Frame

Catalog Number

F

LKD1

J, K

LKD3

L, M, N

LKD4

PG.74A.01.T.E

Cutler-Hammer
March 1999

Molded Case Circuit Breakers
Series C External Accessories

169

Handle Locking and Blocking Devices

Padlockable Handle Lock Hasp

Cylinder Lock
Ordering Information
Description

Catalog
Number

F-Frame
1-pole breakers

PHL1

2-, 3-, 4-pole breakers

PLK1

Instruction Leaflet/FRED Number 29C230

J, K-Frames

The padlockable handle lock hasp
allows the handle to be locked in the
ON or OFF position. (Trip-free operation allows the circuit breaker to trip
when the handle lock holds the circuit breaker handle in the ON position.) The hasp mounts on the circuit
breaker cover within the trimline.
The cover is predrilled on both sides
of the operating handle so that the
hasp can be mounted on either side
of the handle. The hasp will accommodate up to three padlocks with
1/4-inch (6 mm) shackles. Listed per
UL File E7819. (Field installation only.)
The padlockable handle lock can be
mounted on either side of the operating handle. One per circuit breaker.
(Field installation only.)

2-, 3-, 4-pole breakers

PLK3

For Left Side Mounting

PLK3LOFF➀

For Right Side Mounting

PLK3ROFF➀

Instruction Leaflet/FRED Number 29C232

L-Frame
Side Mounted

Lock On or Off

HLK4

Lock Off Only (Left-Hand Mount)

HLK4LOFF➀

Instruction Leaflet/FRED Number 29C234
Top Mounted

Lock On or Off

HLK4S

Lock Off Only

HLK4SOFF➀

Instruction Leaflet/FRED Number 29C234C

Lock On or Off

HLK4

Lock Off Only (Left-Hand Mount)

HLK4LOFF➀

Instruction Leaflet/FRED Number 29C234

Lock On/Off

HLK45

Lock Off Only

HLK45OFF

Instruction Leaflet/FRED Number 29C234C

N-Frame
Side Mounted

PLK5

Instruction Leaflet/FRED Number 29C234

Top Mounted (On/Off)

PLK5S

Top Mounted (Off Only)

PLK5SOFF➀

Instruction Leaflet/FRED Number 29C234C

R-Frame
Lock On/Off

HLK6

Lock Off Only

HLK6OFF➀

Instruction Leaflet/FRED Number 29C240

PG.74A.01.T.E

The cylinder lock is factory installed
in the left pole only of the circuit
breaker cover. Internal accessories
cannot be installed in the same pole
as the cylinder lock.

Ordering Information

M-Frame

Vertical Mounting

➀ For padlockable handle lock hasp to padlock
handle in OFF position only order either
catalog number.

The cylinder lock internally blocks the
trip bar in the tripped position to prevent the circuit breaker from being
switched to ON. The cylinder lock is
factory installed in the circuit breaker
cover. Other internally mounted
accessories cannot be installed in
the same pole as the cylinder lock.
(Factory installation only.)

Frames

Catalog Number

F, J, K

Order by description

170

Cutler-Hammer

Molded Case Circuit Breakers
Series C External Accessories

March 1999

Mechanical Interlocking Devices

Key Interlock Kit
(Lock Not Included)

Ordering Information
Key interlock mounting kits are for
field installation only. Select mounting kit catalog numbers to match
type of lock used. Key interlocks are
supplied by customer.
Lock
Manufacturer

Lock
Type

Bolt Projection Kit
Catalog
in Withdrawn
Number
Position

F-Frame

The key interlock is used to externally lock the circuit breaker handle
in the OFF position. When the key
interlock is locked, an extended
deadbolt blocks movement of the circuit breaker handle. Uniquely coded
keys are removable only with the
deadbolt extended. Each coded key
controls a group of circuit breakers
for a given specific customer
installation.

Superior
Kirk
Square D
Federal Pioneer

B-4003-1
F
SF
VF

3/8 inch
3/8 inch
None
3/8 inch

KYK1

Castell

K or QK

3/8 inch

CTK1

Instruction Leaflet/FRED Number 29C231

J-, K-Frames
Superior
Kirk
Square D
Federal Pioneer
Castell

B-4003-1
F
SF
VF
K or QK

3/8 inch
3/8 inch
None
3/8 inch
3/8 inch

KYK3

Instruction Leaflet/FRED Number 29C233

The key interlock assembly is Underwriters Laboratories, Inc., listed for
field installation under UL file E7819
and consists of a mounting kit and a
purchaser supplied deadbolt lock.
The mounting kit comprises a
mounting plate, which is secured to
the circuit breaker cover in either the
left- or right-pole position, key interlock mounting screws, and a wire
seal. Specific mounting kits are
required for individual key interlock
types.

L-, M-, N-Frames
Superior
Kirk
Square D
Federal Pioneer

B-4003-1
F
SF
VF

3/8 inch
3/8 inch
None
3/8 inch

KYK4

Castell

K or QK

3/8 inch

CTK4

Instruction Leaflet/FRED Number 29C235

R-Frame
Superior
Kirk
Square D
Federal Pioneer

B-4003-1
F
SF
VF

1 inch
1 inch
1 inch
1 inch

KYK6

Castell

K or QK

1 inch

CTK6

Instruction Leaflet/FRED Number 29C240

PG.74A.01.T.E

Cutler-Hammer
March 1999

Molded Case Circuit Breakers
Series C External Accessories

171

Mechanical Interlocking Devices

Sliding Bar Interlock
Ordering Information
➤

➤

The sliding bar interlock provides
mechanical interlocking between
two adjacent 3-pole circuit breakers.
It is installed on the enclosure cover
between the circuit breakers. When
the sliding bar interlock handle is
moved from one side to the other,
a bar extends to alternately block
movement of the circuit breaker
handles and prevents both circuit
breakers from being switched to ON
at the same time. Sliding bar interlocks are not UL listed. (Field installation only.)

The sliding bar interlock is available
for mounting between two adjacent
3-pole circuit breakers with circuit
breakers centerline spacing as indicated in table and enclosure front
panel thickness of 1/8 or 3/16 inch.
(For field installation only.)
Frame

Centerline Spacing
(inches)

Catalog Number

Instruction Leaflet/
FRED Number

F

4-3/16

SBK1

29C310

J

4-3/8

SBK2

29C310

K

5-3/4

SBK3

29C310

L, M

8-1/2

SBK4

29C311

N

8-1/2

SBK5

46A8396

Ordering Information

Walking Beam Interlock
The walking beam interlock provides
mechanical interlocking between
two adjacent circuit breakers of the
same pole configuration. The walking beam interlock mounts on a
bracket behind and between the circuit breakers. A plunger on each end
of the beam is inserted through an
access hole in the back plate and
base of each circuit breaker. The
walking beam interlock prevents
both circuit breakers from being
switched ON at the same time. If a
walking beam interlock is installed,
the wiring troughs in the back of the
circuit breaker case are blocked by
the plungers and cannot be used for
cross wiring. Factory modified circuit breakers are required for this
application. UL File E3816.

PG.74A.01.T.E

The walking beam interlock is available for mounting between two adjacent circuit breakers spaced 1/4-inch
apart and having the same pole configuration. The two circuit breakers
must be factory modified to accept
the walking beam interlock assembly
(suitable for use with either 2-, 3-, or
4-pole circuit breakers). With properly
modified circuit breakers, the walking
beam interlock is suitable for field
installation. Order circuit breakers
specifying modification for walking
beam and select walking beam interlock from table on this page. Circuit
breakers and walking beam interlock
are boxed and shipped separately.
Frame

Catalog Number

Instruction Leaflet/
FRED Number

F

WBL1

29C300

K

WBL3

29C301

L, M

WBL4

29C302

N

WBL5

29C303

R

WBL6

29C304

172

Cutler-Hammer

Molded Case Circuit Breakers
Series C External Accessories

March 1999

Electrical Operator

Electrical Operator➀
EO

Ordering Information
F-Frame
Electrical Rating Data➁

The electrical (solenoid) operator is
a single solenoid mechanism that
enables local and remote circuit
breaker ON, OFF, and reset switching. The electrical operator is
mounted on the circuit breaker
cover within the trimline of the circuit breaker. The electrical operator
uses a unique bistable latch that
allows the device to operate using
one solenoid. The accessory provides high-speed switching with a
maximum operating time of 5 cycles
(80 ms) making it suitable for generator synchronizing applications.
Means are provided for remote electrical operation and for local manual
operation. A special slide includes
provisions for padlocking the circuit
breaker handle in the OFF position.
The slide will accept three padlock
shackles with a maximum diameter
of 1/4-inch (6 mm) each. An interlock
electrically disconnects the solenoid
when the electrical operator cover is
removed. The above table provides
electrical rating data for the electrical (solenoid) operator.

Electrical Operator
Fuse➂
Amperes

Voltage

Frequency

Terminal
Block

18-Inch
Pigtail Lead

Voltage

Frequency

Inrush
Current
Amperes

Maximum
Operating
Time

120➃
240➃

50/60 Hz
Ac

10
5

5 cycles
(80 ms)

3
2

120
240

Ac

EOP1T07
EOP1T11

120➄
240➄

Dc
Dc

14
8

5 cycles
(80 ms)

3-5
2-3

120
240

Dc

EOP1T07DC EOP1P07DC
EOP1T11DC EOP1P11DC

Catalog Number

EOP1P07
EOP1P11

Instruction Leaflet/FRED Number 29C200 (AC); 29C210 (DC)

J-Frame
Electrical Rating Data ➄➅➆➇
Voltage (V)➂

120
240

Inrush Current (A)

Electrical Operator

Fuse (A)

24
12

6
4

Operating
Voltage

Frequency

Terminal Block
Catalog Number

120
240

50/60 Hz
Ac

EOP2T07
EOP2T11

120
240

Dc

EOP2T07DC
EOP2T11DC

Frequency

Terminal Block

Instruction Leaflet/FRED Number 29C202 (AC); 29C211 (DC)

K-Frame
Electrical Rating Data ➄➅➆➇
Voltage (V)➂

120
240

Inrush Current (A)

24
12

Electrical Operator

Fuse (A)

6
4

Operating
Voltage

Catalog Number

120
240

50/60 Hz
Ac

120
240

Dc

EOP3T07
EOP3T11
EOP3T07DC
EOP3T11DC

Instruction Leaflet/FRED Number 29C202 (AC); 29C211 (DC)

The electrical (solenoid) operator is
Underwriters Laboratories, Inc.,
listed as a circuit breaker accessory
under UL File E64983.

➀ The electrical operator design is endurance
tested for 10,000 electrical operations.
➁ Use current-limiting type fuse where
required.
➂ Tolerance: +10%, –15% of nominal voltage.
➃ Tolerance: ±10% of nominal voltage.
➄ Underwriters laboratories listed under UL
file E64983.
➅ The electrical operator design has been
endurance tested for 6,000 electrical
operations.
➆ Frequency: 50/60 Hz.
➇ Maximum operating time: 5 cycles (80 ms).

PG.74A.01.T.E

Cutler-Hammer
March 1999

Molded Case Circuit Breakers
Series C External Accessories

173

Electrical Operator
The motor operator allows the circuit’s breaker to be opened, closed,
or reset remotely. It also has a lockoff capability and provisions for
manual operation.

Ordering Information
L- and M-Frames
Electrical Rating Data ➀➁➂➃
Voltage (V)➄

The motor operator contains a
reversible motor connected to a ball
screw. The ball screw drives the circuit breaker handle. Limit switches
and relays are used to control the
motor.
The motor operator is UL listed as a
recognized component suitable for
field installation on all type L-frame
circuit breakers and molded case
switches under UL File E64124.
From the point of energization of the
closing mechanism at 85% voltage,
the closing time is 30 cycles ± 10%.

Electrical Operator

Inrush Current (A)

Operating
Voltage

Frequency

Terminal Block
Catalog Number

120 Ac
208
240

8
5
4

120
208
240
480

50/60 Hz

125 Dc
24

9
27

125
24

Dc

EOPM4T07
EOPM4T11
EOPM4T11A
EOPM4T15
EOPM4T26
EOPM4T21

Instruction Leaflet/FRED Number 29C203

N-Frame
Electrical Rating Data ➀➂➅➆
Voltage
(V)➄

Frequency

120
208
240
480

50/60 Hz

48
125

Dc

Inrush
Current (A)

Electrical Operator
Fuse
(A)

Operating
Voltage

6

25
21
19

4

80
13

Frequency

Pigtail Leads
Catalog Number

120
208
240
480

50/60 Hz

EOP5T07
EOP5T09
EOP5T11
EOP5T15

48
125

Dc

EOP5T22
EOP5T26

Instruction Leaflet/FRED Number 29C204

R-Frame
Available Motor Operator Ratings
and Operating Conditions➇➈➉
Rating
Voltage (V)

Frequency

Electrical Operator

Motor Inrush
Current (A)

Operating
Voltage

Frequency

Factory Installed
Terminal Block
Catalog Number

120
240
48

50/60 Hz
50/60 Hz
Dc

40
27
53

Instruction Leaflet/FRED Number 29C205

➀ Underwriters Laboratories Inc. listed under
UL File E64983.
➁ The electrical operator design has been
endurance tested for 6,000 electrical
operations.
➂ Frequency: 50/60 Hz.
➃ Maximum operating time: 5 cycles (80 ms).
➄ Tolerance: +10%, –15% of nominal voltage.
➅ The electrical operator design has been
endurance tested for 2,500 electrical
operations.
➆ Maximum operating time: 12 cycles max.
Operator is an intemittent duty device. The
safe duty cycle (OFF to ON to OFF) should
not exceed one per minute.

PG.74A.01.T.E

➇ Operator is an intermittent duty service. The
safe duty cycle (OFF to ON to OFF) should
not exceed one per minute.
➈ Electric Operating time at rated voltage;
(a) To turn breaker ON – 1/2 second max.
(b) To turn breaker OFF – 1/2 second max.
➉ Motor operating temperature; Class “A”
temperature limits apply.
 A minimum 1 kVA power source is recommended for motor operation.
 Applied voltage should be no less than 85%
or no more than 110% of rated.

120
240
48

50/60 Hz
50/60 Hz
Dc

EOP6T08K
EOP6T11K
EOP6T21K

Cutler-Hammer

Molded Case Circuit Breakers
Series C External Accessories

174

March 1999

Plug-in Adapters

Plug-in Adapters
Plug-in adapters simplify installation and front removal of circuit
breakers. Individual line and load
plug-in adapters are available for
rear connection applications on
2-, 3-, and 4-pole circuit breakers.
Common mounting plates for lineand load-end adapters are available.

Ordering Information
F-Frame

100
150-225

L-Frame

K-Frame

3-Pole
Continuous 2-Pole
Current
Style Number
Rating
(Amperes)

4-Pole

Continuous Catalog Number
Current
2-Pole
3-pole
Rating
(Amperes)

507C036G13 507C036G15 179C968G03
507C036G14 507C036G16 179C968G04

Mounting 176C511H01 507C047H01
Plate

400

Instruction Leaflet/FRED Number 13782

Catalog Number
2-Pole

3-pole

PAD33

PAD34

600

506C059G03

506C059G04

➁

PMP33

PMP34

Mounting
Plate

504C824H01

504C824H01

Instruction Leaflet/FRED Number 15378

Instruction Leaflet/FRED Number 29C314

M-Frame

J-Frame
Continuous Current
Rating (Amperes)

Terminal End

250

Line
Load
1 Line and 1 Load

Mounting Plate

Continuous
Current
Rating
(Amperes)

PAD32

Mounting
Plate

➀

4-Pole

2-Pole
Style/Catalog Number

3-Pole

4-Pole

1260C86G05
1260C86G07
506C144G27

1260C86G06
1260C86G08
506C144G28

1231C67G01
1231C67G02
–

➁

PMP23

–

–

Instruction Leaflet/FRED Number 149321

Continuous
Current
Rating
(Amperes)

800

Catalog Number
2-Pole

3-Pole

2614D53G05

Mounting
Plate

2614D53G06

1290C73H01

Instruction Leaflet/FRED Number 15073

N-Frame
Continuous
Current
Rating
(Amperes)

1200
Mounting
Plate

Style Number
2-Pole

3-pole

2614D53G03

2614D53G04

1290C73H01

Instruction Leaflet/FRED Number 13782

➀ Refer to Cutler-Hammer for availability.
➁ Use 3-pole mounting plate for 2-pole circuit
breaker.

PG.74A.01.T.E

Cutler-Hammer

Molded Case Circuit Breakers
Series C External Accessories

March 1999

Rear Connecting Studs

Rear Connecting Studs
Rear connecting studs are available
in several sizes to accommodate
specific fixed-mounted circuit
breaker applications.
Each rear connecting stud assembly
consists of one stud and one tube.
To maintain proper clearances
between poles, select alternate long
and short stud assemblies for circuit
breakers with more than one pole.
One assembly is required for lineend and one for load-end of each
pole. Tubes must be ordered separately. Connecting studs are available only with English thread sizes.

Ordering Information
F-Frame

E
B
Mounting Panel

“F” Thread

Breaker Mounting
Surface

1
316
4

Stud
Ampere
Rating

Stud Style
Number

A

C
D

Panel Thickness
(Inches)

Tube Length
(Inches)

A

B

Tube
Style
Number

C

Dimensions
(Inches)
D

E

F

For 15A to 100A Circuit Breakers
100A Short
100A Short
100A Short
100A Short

451D874G01
451D874G01
451D874G01
451D874G01

1
1-1/16 to 15/16
3/8 to 5/8
1/4 to 5/16

11/16
13/8
1-11/16
2

–
–
–
–

32B9446H20
32B9446H21
32B9446H22
32B9446H23

–
–
–
–

100A Long
100A Long
100A Long
100A Long

451D874G02
451D874G02
451D874G02
451D874G02

1
1-1/16 to 15/16
3/8 to 5/8
1/4 to 5/16

–
–
–
–

3-7/16
3-3/4
4-1/16
4-3/8

32B9446H24
32B9446H25
32B9446H26
32B9446H27

6-1/8

3-5/8 15/16 - 18

–
–
–
–

For 110A to 150A Circuit Breakers
150A Short
150A Short
150A Short
150A Short

374D883G01
374D883G01
374D883G01
374D883G01

1
11/16 to 15/16
3/8 to 5/8
1/4 to 5/16

11/16
13/8
1-11/16
2

–
–
–
–

374D883H06
374D883H07
374D883H08
374D883H09

–
–
–
–

150A Long
150A Long
150A Long
150A Long

374D883G02
374D883G02
374D883G02
374D883G02

1
11/16 to 15/16
3/8 to 5/8
1/4 to 5/16

–
–
–
–

3-7/16
3-3/4
4-1/16
4-3/8

374D883H10
374D883H11
374D883H12
374D883H13

7-1/2

PG.74A.01.T.E

4-1/4 1/16 - 14

–
–
–
–

175

176

Cutler-Hammer

Molded Case Circuit Breakers
Series C External Accessories

March 1999

Rear Connecting Studs

Rear Connecting Studs
Ordering Information
J-Frame

L-Frame
6 21
32

1 19
32
19
32

A
Insulators

C

A
1
32

1
16
5
16

7
16

Washer
Nut

18 Thread

Do Not Use More
Than 10 Ft. Lbs.
Torque to Tighten Nuts

1
2

Breaker

Insulating Panel
B

Mounting Panel

3 58

Stud Style Number

Stud
Ampere
Rating

5010D23G01
5010D23G01
5010D23G01
5010D23G02
5010D23G02
5010D23G02

250A Short
250A Short
250A Short
250A Long
250A Long
250A Long

Rear
Connecting
Stud

Circuit Breaker

13 Thread

Panel
Thickness
(Inches)

Tube Length
(Inches)

A

B

Stud Length
(A)

Stud Style
Number

5-15/32
7-31/32
10-15/32

Tube Style Number

314C960G07
314C960G08
314C960G09

C

456D983H05
456D983H06
456D983H07
5010D23H05
5010D23H06
5010D23H07

–
–
–
37/8
41/8
43/8

27/32
1-3/32
1-1/32
–
–
–

3/4 – 1
1/2 – 3/4
1/4 – 1/2
3/4 – 1
1/2 – 3/4
1/4 – 1/2

Stud
Ampere
Rating

225
400
400
400
600
600
600
800
800
800

K-Frame
E
B

Mounting Panel

M-Frame➀
Diameter,
Inches
and
Thread

Extension
Back of
Breaker,
Inches

1/2-13
3/4-16
3/4-16
3/4-16
1-12
1-12
1-12
1-1/8-12
1-1/8-12
1-1/8-12

3-21/32
5-29/32
8-13/32
10-29/32
5-29/32
8-13/32
10-29/32
5-29/32
8-13/32
10-29/32

Stud
Style
Numbers

314C960G01
314C960G04
314C960G05
314C960G06
314C960G07
314C960G08
314C960G09
314C960G10
314C960G11
314C960G12

“F” Thread
Breaker Mounting
Surface

N-Frame➀
1
16

A

400A Short
400A Short
400A Short
400A Long
400A Long
400A Long

Stud Style
Number

6642C14G02
6642C14G04
6642C14G06
6642C14G03
6642C14G05
6642C14G07

D

Panel Thickness
(Inches)

Tube Length
(Inches)

A

B

C

27/32
1-3/32
1-11/32
–
–
–

–
–
–
3-25/32
4-1/32
4-9/32

3/4 to 1
1/2 to 3/4
1/4 to 1/2
3/4 to 1
1/2 to 3/4
1/4 to 1/2

Diameter,
Inches
and
Thread

800
800
800
1200
1200

1-1/8-12
1-1/8-12
1-1/8-12
1-1/4-12
1-1/4-12

C

1 43
64

Stud
Length

Stud
Ampere
Rating

Standard
Tube Style
Number

Dimensions
(Inches)
D

E

F

313C909H17
313C909H18
313C909H19
313C909H20
313C909H21
313C909H22

–
–
–
–
6-37/64
–

3-21/32

3/4 - 16

Extension
Back of
Breaker,
Inches

5-1/2
8
10-1/2
5-1/2
10-1/2

Stud
Style
Numbers

623B222G01
623B222G02
623B222G03
373B375G04
373B375G03

➀ Not UL listed.

PG.74A.01.T.E

Cutler-Hammer

Molded Case Circuit Breakers
Series C External Accessories

March 1999

177

Panelboard Connecting Straps

Panelboard Connecting Straps
J-Frame

M-Frame
Panelboard Connecting Straps

Panelboard Connecting Straps
Bus
Spacing
(Inches)

Continuous
Current
Rating
(Amperes)

3-1/2

250

Pole Connector Type
Center

Outside

Bus
Spacing
(Inches)

Continuous
Current
Rating
(Amperes)

3-1/2

800

Style Number

2600D26G01

2600D26G02

Panelboard connecting straps are
used to connect the circuit breaker
terminals to the panelboard bus.
The panelboard connecting straps
are available with various ratings for
outside and center poles. (Field
installation only.)

Ordering Information

Refer to panelboard manufacturer
for compatibility.

Panelboard Connecting Straps
Continuous
Current
Rating
(Amperes)

Pole Connector Type
Center

2-3/4
2-3/4
2-3/4

50
100
150

673B142G02
673B142G02
673B142G04

673B142G09
673B142G10
673B142G03

3-1/2
3-1/2
3-1/2

50
100
150

1253C72G01
1253C73G03
1253C73G01

1253C72G03
1253C73G06
1253C73G05

Mounting Bracket
Style Number

2

624B600H02

3

624B600H01

PG.74A.01.T.E

Mounting Bracket
Style Number

N-Frame

Panelboard Connecting Straps
Bus
Spacing
(Inches)

Continuous
Current
Rating
(Amperes)

400

Pole Connector Type
Center

Outside

Style Number

4212B78G02

Panelboard Connecting Straps
Bus
Spacing
(Inches)

Continuous
Current
Rating
(Amperes)

3-1/2

1200

4212B77G01

Mounting Bracket
Number of Poles

Connector
Type

2, 3

208B264H01

Style Number

Short
Medium
Long

315C270H01

Panelboard Connecting Straps
Pole Connector Type
Center

Outside

Style Number

624B609G01

Number of Poles

2, 3

505C606G04
505C606G05
505C606G06

Mounting Bracket (Four (4) Required)
Style Number

L-Frame

600

Pole Connector
Type

Style Number

506C052G01

Mounting Bracket

Style Number

314C996G01
314C996G02
314C996G03

315C270H01

Outside

5-3⁄4-Inch Deep Box, 600 Vac Maximum

Number of Poles

1576707

Style Number

K-Frame

Continuous
Current
Rating
(Amperes)

F-Frame
Bus
Spacing
(Inches)

2, 3

3-1/2

Panelboard connecting straps are
available to meet the needs of most
standard panelboard applications.
Style numbers for mounting brackets for CDP panelboard installations
are also included.

Style Number

Pole Connector
Type

Short
Medium
Long

Mounting Bracket
Number of Poles

Connector
Type

Style Number

208B297H01

178

Cutler-Hammer

Molded Case Circuit Breakers
Series C External Accessories

March 1999

Handle Mechanisms

Flange Mounted Flex Shaft
Ordering Information
Catalog Number includes complete
assembly consisting of C371 handle,
flexible shaft, operating mechanism,
and door interlock hardware to fit
industry standard flange cutout.
Length of Flex Shaft
(in feet)

Catalog
Number

F-Frame➁

The Flex Shaft type handle mechanism is an extra heavy-duty handle
mechanism designed for mounting
in flange-type enclosures. An operating handle, flexible shaft, and
mechanism are required for
standard application.

3
4
5
6
7
8
9
10

Instruction Leaflet/FRED Number 15609

J-Frame➁
3
4
5
6
7
8
9
10

The handle can be locked in the
RESET position with up to three
padlocks. The handle is suitable
for Types 1, 3R, 4➀, 4X➀, and 12 fabricated enclosures. The handle fits
the industry standard cutout.
Eight lengths of shafts are available
for use with the wide range of
depths of various enclosures (3 feet
through 10 feet). These choices
enable this mechanism to be
mounted in various depth, width,
and height enclosures.
Note: when selecting the length of
shaft, ensure minimum bending
radius of 4 inches is maintained
to operate properly.

F2S03C
F2S04C
F2S05C
F2S06C
F2S07C
F2S08C
F2S09C
F2S10C

Instruction Leaflet/FRED Number 15605

K-Frame➁
3
4
5
6
7
8
9
10

F3S03C
F3S04C
F3S05C
F3S06C
F3S07C
F3S08C
F3S09C
F3S10C

Instruction Leaflet/FRED Number 15604

L- and M-Frames

The standard method of shipment
includes the mechanism preset at
the factory; however, minor field
adjustments may be required.
For this publication, the term
Circuit Breaker shall also include
the molded case switch and Series C
motor circuit protector (HMCP).

F1S03C
F1S04C
F1S05C
F1S06C
F1S07C
F1S08C
F1S09C
F1S10C

4
5
6
10

F4S04
F4S05
F4S06
F4S10

Instruction Leaflet/FRED Number 15606

N-Frame
4
5
6
10

UL File E64893.

F5S04
F5S05
F5S06
F5S10

Instruction Leaflet/FRED Number 15606

R-Frame
➀ Type 4/4X handle mechanisms are available.
Add suffix X to complete catalog number.
➁ Add suffix I to complete catalog number for
IEC handle. Add suffix L to complete catalog
number for 6-inch handle.

4
5
6

F6S04
F6S05
F6S06

Instruction Leaflet/FRED Number 15606

PG.74A.01.T.E

Cutler-Hammer
March 1999

Molded Case Circuit Breakers
Series C External Accessories

179

Handle Mechanisms

Flange Mounted
Type SM Safety

Through-the-Door
Type MC Motor Control
Ordering Information
Description

Catalog Number

F-Frame
For use with Type 1
Enclosure Catalog

SMCU150FD

For use with Type 12
Enclosure Catalog

CMCU150FD

Instruction Leaflet/FRED Number 14572

J-Frame

The SM safety handle mechanism
provides a means of externally operating a circuit breaker mounted in an
enclosure and is designed to reduce
the possibility of circuit breaker tampering. The handle mechanism is
especially suited for use in automotive and machine tool industries
through its conformance to Type 12
and J. I. C. requirements. A specially
modified handle mechanism for
Type 4 enclosure application is also
available order by description. The
handle mechanism will accept up to
three padlock shackles, each with a
maximum diameter of 3/8 inch
(9.52mm). UL File E64893.

The MC motor control handle mechanism is a linear-operating, fixeddepth mechanism designed for
through-the-door mounting in standardized and shallow depth enclosures. The handle mechanism provides positive operation and direct
disconnect status indication. It is
interlocked with the enclosure door
so that the door can be opened only
when the handle is set to OFF.
(A defeater, supplied with the handle
mechanism, can be used to bypass
the interlock for maintenance and
inspection.) The handle mechanism
will accept up to three padlock shackles, each with a maximum diameter
of 3/8 inch (7.92 mm).UL File E56845.

For use with Type 1
Enclosure Catalog

SMCU250JD

For use with Type 12
Enclosure Catalog

CMCU250JD

Instruction Leaflet/FRED Number 29C273

K-Frame
For use with Type 1
Enclosure Catalog

SMCU400KD

For use with Type 12
Enclosure Catalog

CMCU400KD

Instruction Leaflet/FRED Number 29C273

M-Frames
For use with Type 1
Enclosure Catalog

SMCU600LD

For use with Type 12
Enclosure Catalog

CMCU600LD

Instruction Leaflet/FRED Number 29C283

Ordering Information
Description

Catalog Number

F-Frame
Right-Hand Mounting Enclosure Cover

Hinged on Left

SM150R

Left-Hand Mounting Enclosure Cover

Hinged on Right

SM150L

Right-Hand Mounting Enclosure Cover

Hinged on Left

SM250JR

Left-Hand Mounting Enclosure Cover

Hinged on Right

SM250JL

Right-Hand Mounting Enclosure Cover

Hinged on Left

SM400KR

Left-Hand Mounting Enclosure Cover

Hinged on Right

SM400KL

Instruction Leaflet/FRED Number 14439

J-Frame

Instruction Leaflet/FRED Number 29C274

K-Frame

Instruction Leaflet/FRED Number 29C274

L- and M-Frames
Hinged on Left

SM600R

Hinged on Right

SM600L

Instruction Leaflet/FRED Number 29C284
➀ Width spacer kits cannot be used with short
rod at minimum enclosure depth.

PG.74A.01.T.E

180

Cutler-Hammer

Molded Case Circuit Breakers
Series C External Accessories

March 1999

Handle Mechanisms

Through-the-Door Rotary

These compact rotary handle mechanisms are especially designed for
use with the GD/GC/GHC circuit protection devices. The Close-Coupled
version is designed for mounting in
a shallow enclosure, while the VariDepth is suitable for deep enclosures.
Both G-frame handle mechanisms
are suitable for use on Type 1 enclosures. In addition, the Vari-Depth
handle mechanism is offered for use
with Types 3R, 12, and 4X enclosures.
The new handles are a compact,
plastic, general purpose design
which is easy to install. These mechanisms are commonly used where
high volume, standardized enclosures are being fabricated.

Ordering Information
Breaker
Frame

Enclosure
Type

Handle
Color

Shaft
Length

Shroud
Included

Catalog
Number

G-Frame Vari-Depth Design
(Catalog Number includes complete assembly consisting of handle, shaft, and operating mechanism.)
GD/GC/GHC
GD/GC/GHC
GD/GC/GHC
GD/GC/GHC

Type 1
Type 1
Type 3R/12/4X
Type 3R/12/4X

Black
Yellow
Black
Yellow

14 inches

–

HRGCV11L
HRGCV31L
HRGCV14L
HRGCV34L

G-Frame Close-Coupled Design
(Catalog Number includes complete assembly consisting of operating handle and door interlock.)
GD/GC/GHC
GD/GC/GHC
GD/GC/GHC
GD/GC/GHC

Type 1
Type 1
Type 1
Type 1

Black
Black
Yellow
Yellow

–

No
Yes
No
Yes

HRGCC10
HRGCC1S
HRGCC30
HRGCC3S

Instruction Leaflet/FRED Number 15567 (Close Coupled);
Instruction Leaflet/FRED Number 15569 (Variable Depth)

The Close-Coupled design is available with or without a shroud. The
handle is offered in two colors; black
or yellow. An escutcheon ring and
interlock clip are provided as standard. This standard design includes
a lock-off feature.
The Vari-Depth design includes an
operating mechanism, shaft, and
external handle. The handle is available in two colors; black or yellow.
An external lock-off is included in
the handle design. The shaft may be
cut to size to fit the enclosure.
UL and CSA listed.

PG.74A.01.T.E

Cutler-Hammer
March 1999

Molded Case Circuit Breakers
Series C External Accessories

181

Handle Mechanisms

Through-the-Door Rotary
Ordering Information
Shaft
Length
(Inches)

Complete
Catalog
Number➀

Catalog Number

Separate Style Number
Standard
Handle➂

Breaker
Mechanism➃

Shaft➄

IEC IP65➄➅

IEC IP66➄➅

F-Frame
6
12
16
24

HM1R06
HM1R12
HM1R16
HM1R24

6648C22G01
6648C22G01
6648C22G01
6648C22G01

6648C23G11
6648C23G11
6648C23G11
6648C23G11

4217B37G04
4217B37G01
4217B37G02
4217B37G03

WHM1R06
WHM1R12
WHM1R16
WHM1R24

WHM1R06X
WHM1R12X
WHM1R16X
WHM1R24X

6648C23G02
6648C23G02
6648C23G02
6648C23G02

4217B37G04
4217B37G01
4217B37G02
4217B37G03

WHM2R06
WHM2R12
WHM2R16
WHM2R24

WHM2R06X
WHM2R12X
WHM2R16X
WHM2R24X

6648C23G13
6648C23G13
6648C23G13
6648C23G13

4217B37G04
4217B37G01
4217B37G02
4217B37G03

WHM3R06
WHM3R12
WHM3R16
WHM3R24

WHM3R06X
WHM3R12X
WHM3R16X
WHM3R24X

6648C23G07
6648C23G07
6648C23G07
6648C23G07

4217B37G04
4217B37G01
4217B37G02
4217B37G03

WHM4R06
WHM4R12
WHM4R16
WHM4R24

WHM4R06X
WHM4R12X
WHM4R16X
WHM4R24X

6648C23G07
6648C23G07
6648C23G07
6648C23G07

4217B37G04
4217B37G01
4217B37G02
4217B37G03

WHM5R06
WHM5R12
WHM5R16
WHM5R24

WHM5R06X
WHM5R12X
WHM5R16X
WHM5R24X

Instruction Leaflet/FRED Number 15594

J-Frame

The general purpose rotary handle
mechanisms are suitable for use
with Types 1, 3R, (4, 4X), and 12
fabricated enclosures. They are
designed for use with Series C
F-frame circuit breakers, molded
case switches, and motor circuit
protectors (HMCP).
Required for a standard application
are the operating handle, shaft, and
mechanism.
The operating handle has been
designed to meet NFPA 79 requirements. It may be mounted in either
the horizontal or the vertical direction. The handle was ergonomically
designed with extra clearance for a
“gloved hand” to operate. It may be
padlocked in the OFF position utilizing 3 padlocks.
The standard label on the operating
handle indicates ON/Tripped/OFF/
Reset. UL File E64893
To meet the various enclosure
depths, four variable depth shafts
are offered (6-inch, 12-inch, 16-inch,
and 24-inch). Each shaft includes a
support brace to ensure proper
alignment. In addition, the 16-inch
and 24-inch extra long shafts include
an adjustable support bracket.
The standard mechanism located on
the breaker does include means for
internally locking the breaker in the
“OFF” position with up to three
padlocks each with a maximum
diameter of.312-inch.

6
12
16
24

6648C22G01
6648C22G01
6648C22G01
6648C22G01

Instruction Leaflet/FRED Number 15599

K-Frame
6
12
16
24

HM3R06
HM3R12
HM3R16
HM3R24

6648C22G01
6648C22G01
6648C22G01
6648C22G01

Instruction Leaflet/FRED Number 15600

L- and M-Frames
6
12
16
24

HM4R06
HM4R12
HM4R16
HM4R24

6648C22G11
6648C22G11
6648C22G11
6648C22G11

Instruction Leaflet/FRED Number 15601

N-Frame
6
12
16
24

HM5R06
HM5R12
HM5R16
HM5R24

6648C22G11
6648C22G11
6648C22G11
6648C22G11

Instruction Leaflet/FRED Number 15602

Type 4/4X handles are similar to standard handles except they include an
internal neoprene gasket. Type 4/4X
handle style number is 6648C22G03.
Due to gasketing effect between the
handle and the housing, the handle
may not indicate a tripped position.
Accessories
As an option, an auxiliary switch is
offered so that the control panel
builder may electrically indicate the
status of the breaker. This accessory
would be mounted on the mechanism and comes with 24-inch pigtail
leads.
Style Number

PG.74A.01.T.E

HM2R06
HM2R12
HM2R16
HM2R24

5108A61G01

Refer to CD-ROM, SA.74A.01.T.E,
for replacement type Vari-depth
and AMT handle mechanisms.

➀ Complete catalog number includes the standard handle, mechanism, shaft, and support
brace/bracket.
➁ Handle is designed suitable for Types 1, 3R,
and 12 enclosures. Use style number
6648C22G03 for Type 4/4X handle or add X
suffix to complete catalog number.
➂ The standard handle label indicates ON/
Tripped/OFF/Reset.
➂ Breaker mechanism includes a shaft support
bracket and its parts.
➃ Longer shafts (16-inch and 24-inch) include
an adjustable support extension.
➄ IEC Handle Mechanism supplied with Metric
thread mounting hardware.
➅ Complete Catalog Number includes a
handle, mechanism and shaft.

182

Cutler-Hammer

Molded Case Circuit Breakers
Series C External Accessories

March 1999

Handle Mechanisms

Door Hardware
F-, J-, K-, L- and M-Frames
Door Hardware listed in this section
may be used with Types SM and
AMT handle mechanisms.
Three choices of door hardware and
an auxiliary handle are offered to
provide the best latching scheme for
individual needs. The door hardware is designed with a provision
for padlocking, and a coin-proof slot
that requires the use of a tool to
open the door.
Select desired hardware below.
Additional latches can be ordered
from accessories section if desired.
Hardware
Item

Description and
Catalog Number

Accessories
Dress Nameplates:
Required to meet automotive specifications. Mounts
from inside enclosure and
covers operating mechanism mounting bolts;
makes mechanism nonremovable when enclosure
door is closed.
Description

Door Operated Interlock Defeater
Kit for Type SM Mechanisms
Required when door hardware is not
used, operates as door closes. Additional method of securing door such
as screw latch, also required (supplied by box manufacturer).
Description

Style Number

Door Operated
Interlock Defeater Kit

623B214G02

Style Number

Dress Nameplate

373D260G05

Electrical Interlock Kit: Provides 1
N.C. and 1 N.O. contacts (SPDT
switch) for use with auxiliary circuits. Mounts to end of mechanism
housing as shown.

Remote Mounting Kit (J-Frame)
Enables the operating mechanism to
be mounted remotely on a vertical
centerline from the circuit breaker or
disconnect switch.
Description

Style Number

Remote Mounting Kit

With sliding latches for smaller
panels up to approx. 30-inch high.

505C367G01

Handle Extension

Catalog Number
Right Hand: DH1R
Left Hand: DH1L
Instruction Leaflet/FRED
Number 13327(L); 13326(R)

With 2-roller latches for
intermediate panels up to
approx. 40-inch high.
Catalog Number
Right Hand: DH2R
Left Hand: DH2L
Instruction Leaflet/FRED
Number 13325(L); 13324(R)

With 3-roller latches for larger
panels, approx. 40-inch and
higher.

Description

Style Number

Electrical Interlock Kit

622B747G01

Auxiliary Latch Kits: Provide an
additional latch for use with applications where two point latching may
not be adequate.
Handle extension is not included with
J-, K-, L-, and M-Frame breakers. It
must be purchased separately.

Catalog Number
Right Hand: DH3R
Left Hand: DH3L

Frame

Catalog Number

Instruction Leaflet/FRED
Number 13323(L); 13322(R)

J, K

HEX3

Auxiliary handle for larger panels.

L, M

HEX4

Catalog Number
Right Hand: DH4R
Left Hand: DH4L

Sliding Latch
Description

Rolling Latch
Style Number

For Door Hardware Using Sliding Latches
Right- or Left-Hand Mounting

Note: Right-hand enclosure cover
hinged on left, left-hand enclosure
cover hinged on right.

Handle extension is included with
breaker with N- and R-Frame
breakers.

622B747G01

For Door Hardware Using Rolling Latches
Right-Hand Mounting

370D801G04

Left-Hand Mounting

370D802G04

Frame

Catalog Number

N

HEX5

R

HEX6

PG.74A.01.T.E

Cutler-Hammer

Molded Case Circuit Breakers
Series C External Accessories

March 1999

Current Limiters

Type LFD

The LFD current limiter is an accessory that bolts to the load end of a
standard FDB or FD thermal-magnetic circuit breaker, providing
200,000A interrupting capacity at up
to 600 Vac. LFD current limiters for
thermal-magnetic circuit breakers
are listed with Underwriters Laboratories, Inc., under File E47239.

Ordering Information
Circuit Breaker Rating Amperes➀

15-70
80-160

Catalog Number

LFD3070R
LFD3150R

Instruction Leaflet/FRED Number 29C407

➀ Underwriters Laboratories Inc. listed under
UL File E64983.

PG.74A.01.T.E

183

184

Cutler-Hammer

Molded Case Circuit Breaker
Series C External Accessories
Ground Fault Alarm Unit

March 1999

monitor power and energy readings.
It represents an alternative to watt
meters, watt-hour meters, and watt
demand meters. Key advantages
include savings in space, lower
installation costs, and remote monitoring capability.

Instruction Leaflet/FRED Number 17437

The solid-state (electronic) portable
test kit provides verification of performance of all ratings of Digitrip
310 electronic trip units installed in
Series C circuit breakers while in
service under varying load and/or
phase imbalance. The test kit operates on 120-volt, 50/60 Hz power; it
includes complete instructions and
test times for testing long time,
short time/instantaneous operation
and optional ground fault operation
of the circuit breaker.

For more information see
Descriptive Bulletin 8178.

Ordering Information

The IQ Energy Sentinel mounts on
the load side of a Series C F-frame
(150 ampere) circuit breaker. It can
be applied on three-phase, four-wire
systems, or single-phase, three-wire
systems with voltage connected
through phases A and C.
The Ground Fault Alarm Unit is a
remotely mounted device with a
combination indicating light/test
button that will light when the
breaker trips or alarms on ground
fault. The Ground Fault Alarm Unit
requires a separate 120 Vac power
source to power the light and the
internal relay which has 1 N.O. and
1 N.C. contacts for remote indication. The Ground Fault Alarm Unit
can be panel mounted for ordering
with an optional face mounting
bracket. For use on Digitrip 310 only.
K- through N-frame.

Solid-State (Electronic)
Portable Test Kit

Potential Transformer Module

Description

Solid-State (Electronic)
Portable Test Kit

Catalog Number

STK2

Ordering Information
Catalog Number

GFAU – Ground Fault Alarm Unit
Style Number

1264C67G01 – Face Mounting Bracket
Instruction Leaflet/FRED Number 29C614 Diagram

IQ Energy Sentinel

The Potential Transformer Module is
required for Series C, Digitrip OPTIM
1050, to provide a voltage input to
allow the trip unit to monitor power
and energy as well as power factor.
The Potential Transformer Module is
a 6 VA transformer with a primary
voltage input of up to 600V line to
line. Three 0.1 ampere fuses are provided on the primary of the transformer and can be used for isolation
purposes during dielectric testing.
The device is normally panel
mounted and can feed up to 16
OPTIM trip units.

Ordering Information
The IQ Energy Sentinel is a highly
accurate, microprocessor-based,
breaker-mounted device designed to

Description

Potential Transformer Module

Catalog Number

DOPTMLN

Instruction Leaflet/FRED Number 29C894 Diagram

➀ Model 550 OPTIMs require the Cutler-Hammer
PowerNet field upgrade kit.

PG.74A.01.T.E

Cutler-Hammer
March 1999

Molded Case Circuit Breakers
Series C External Accessories

185

OPTIM System Components

Breaker Interface Module
(BIM)

The Breaker Interface Module (BIM)
is a panel mounted user interface
device that is mounted on the front
of an electrical assembly or at a
remote location. The BIM is used to
access, configure, test and display
information for OPTIM trip units and
other devices. The BIM consists of
four display windows, eight function
buttons, 18 LEDs, and a graphical
time/current curve to provide
breaker status, operational information, protection status and energy
monitoring. A 24 Vdc power supply
is required to provide power to the
BIM. This is supplied by the switchboard builder to Cutler-Hammer
specifications. The BIM is a member
of the Cutler-Hammer PowerNet
family of communicating devices
that connects OPTIM trip units,
Digitrip RMS 810/910 trip units and
energy sentinels as a subnetwork
system. The BIM can also be connected to a main network via a PONI
module to Cutler-Hammer PowerNet
software.

Digitrip OPTIMizer

The Digitrip OPTIMizer is a handheld programmer that is used to
access, configure, test and display
information from OPTIM trip units.
The OPTIMizer plugs into the front
of an OPTIM trip unit via an eightpin telephone jack and is powered
by a nine-volt battery or the auxiliary power module. In addition,
a three-pin INCOM network connection is also provided to program
other OPTIM devices on the system.
An Auxiliary Power Module connection provides a trip test when control power is not present at the
breaker. The OPTIMizer is supplied
as a standard package to include the
programmer, the eight-pin connection cord, battery and carrying case.
The Auxiliary Power Module is
optional.

Auxiliary Power Module

The Auxiliary Power Module is a
power supply requiring 120 Vac
input at 50 or 60 Hz that provides a
32 Vdc output➀. The Auxiliary Power
Module provides control power for
testing an OPTIM trip unit when
other means of control power is not
available or for continuous OPTIMizer
operation versus temporary with a
battery. The Auxiliary Power Module
connects into the top of the Digitrip
OPTIMizer via a keyed receptacle.
The main application for the Auxiliary Power Module would be for the
testing of a stand-alone non-communicating OPTIM breaker that ordinarily would not have control power.

Ordering Information
Catalog Number

PRTAAPM

Cutler-Hammer PowerNet
Software

Ordering Information
Catalog Number

OPTIMizer – Standard Package
Instruction Leaflet/FRED Number 29C892

Ordering Information
Catalog Number

BIM
Instruction Leaflet/FRED Number 29C893

➀ The OPTIMizer can work off of 32 Vdc control
power, although 24 Vdc is the standard on
OPTIM breakers.
➁ Model 550 OPTIMS require the Cutler-Hammer
PowerNet field upgrade kit.

PG.74A.01.T.E

Note: 24 Vdc Power Supply
A 24 Vdc power supply is required for all Digitrip
OPTIM trip units that are required to communicate either on the main Cutler-Hammer PowerNet
network or as a subnetwork to a BIM. The breaker’s load is 45 mA of current. Typically one power
supply is required per switchboard and can provide control power to a BIM and the OPTIM trip
units. The 24 Vdc power supply should be an
“isolated high quality” power supply with a
“CE” label, and is normally provided by the
switchboard manufacturer to Cutler-Hammer
recommendations.

Series C Digitrip OPTIM trip units
can communicate back to a central
Personal Computer by installing
Cutler-Hammer PowerNet software➁.
In addition other software packages
are available to allow the user to
configure the trip units as well as
monitor system performance.
Instruction Leaflet/FRED Number 29C890

186

Molded Case Circuit Breakers
Special Modifications

Cutler-Hammer
March 1999

Special Calibration➀

Moisture-Fungus Treatment

Marine Applications

Special non-UL-listed calibrations
are available for certain ambient
temperatures other than 40°C and
for frequencies other than 50/60 Hz
or Dc. Reduced interrupting ratings
will apply for 400 Hz applications.
Maximum thermal calibration is
limited to 135A at 400 Hz.

All Series C circuit breaker cases are
molded from glass-polyester which
does not support the growth of fungus. Any parts which are susceptible
to the growth of fungus will require
special treatment.

F-Frame circuit breakers can be supplied to meet the following marine
specifications:

Suffix H01 400 Hz.
See Application Data 29-160 for
information regarding special
conditions.
50°C Calibration➀
Add suffix “V” to catalog number
for complete breaker, listed above,
when ordering listed ampere ratings
for breakers to be used in 50°C
ambients.

Suffix J01 Fungus Treated

Freeze-Tested Circuit
Breakers
The circuit breakers may be ordered
with freeze testing. This option uses
special lubrication and mechanical
operation is verified at -40°C.
Suffix F01 Freeze Tested.

U.S. Coast Guard CFR 46 ABS –
American Bureau of Shipping
IEEE 45
These specifications generally
require molded case circuit breakers
to be supplied with 50°C ambient
calibration, special nameplating,
and plug-in adapter kits. When plugin adapter kits are used, no terminals need be supplied.
Series C circuit breakers can also be
supplied to meet UL489 Supplement
SA (Marine Use) and UL489 Supplement SB (Naval Use).
UL489 Supplement SA applies to
vessels over 65 feet in length.
Requirements include 40°C ambient
calibration, special labeling, and
no use of aluminum conductors or
terminals.
Suffix H08 “Marine.”
UL489 Supplement SB requires 50°C
ambient calibration, vibration testings, special nameplating and no
use of aluminum conductors or
terminals.
Suffix H09 “Naval.”

➀ Not listed with Underwriters Laboratories,
Inc.
➁ For use with standard 35 mm DIN rail such
as, 35 x 7.5 or 15 mm per DIN EN50022.

PG.74A.01.T.E

Cutler-Hammer
March 1999

Molded Case Circuit Breakers
Enclosures

NEMA 1 General Purpose

NEMA 3R Rainproof
Surface Mounting

Surface or Flush Mounting
15-1200 Ampere Range
600 Volts Ac, 500 Volts Dc
NEMA 1 enclosed breakers are
designed for indoor use in commercial buildings, apartment buildings
and other areas where a general purpose enclosure is applicable. The
breaker is front operable and is capable of being padlocked in the Off
position. (Padlocking not available
on enclosures for Quicklag breakers.) Ratings through 1200 amperes
are listed with Underwriters Laboratories, Inc. as suitable for service
entrance application. Both surface
and flush mounted enclosures are
available. UL File Number E7819.
CSA File Number LR84319.

Interchangeable Hubs (through
400 amperes)15-1200 Ampere Range
600 Volts Ac, 500 Volts Dc
This general purpose outdoor service center employs a circuit breaker
inside a weatherproof sheet steel
enclosure to serve as a main disconnect and protective device for feeder
circuits. The operating handle can be
padlocked in the Off position, and is
interlocked to prevent the door from
opening when the breaker is On. Ratings through 1200 amperes are
listed by Underwriters Laboratories,
Inc. as suitable for service entrance
application. UL File Number E7819.
CSA File Number LR84319.

NEMA 12 Dustproof
Surface Mounting

severe conditions involving oil, coolant, dust and other foreign materials
exist in the operating atmosphere.
The handle padlocks in the Off position and the cover is interlocked with
the handle mechanism to prevent
opening the cover with the circuit
breaker in the On position. Ratings
through 1200 amperes are listed by
Underwriters Laboratories, Inc. as
suitable for service entrance application. A NEMA 12 semi-dust-tight
design which includes knockouts
is available. These units are rated
15-400 amperes, 600 volts Ac, 500
volts Dc. UL File Number E7819.
CSA File Number LR84319.

No Knockouts or Other Openings
15-1200 Ampere Range
600 Volts Ac, 500 Volts Dc
The Type 12 enclosure is designed in
line with specifications for special
industry application where unusually

PG.74A.01.T.E

NEMA 4/4X, 5 Water
and Dustproof

Stainless Steel – Type 304
Surface Mounting
15-1200 Ampere Range
600 Volts Ac, 500 Volts Dc
This enclosure meets NEMA 4/4X
and 5 requirements for water and
dustproof applications and has no
knockouts or other openings. It is
particularly well suited for use in
dairies, borax mines, breweries,
paper mills and other process industries. The operating handle can be
padlocked in the Off position, and is
interlocked to prevent the door from
opening when the breaker is On.
Ratings through 1200 amperes are
Underwriters Laboratories, Inc. listed
as suitable for service entrance
application. UL File Number E7819.
CSA File Number LR84319.

NEMA 7, 9 Hazardous
Location
Cast Aluminum, Explosionproof
Surface Mounting
15-800 Ampere Range
600 Volts Ac, 250 Volts Dc
Hazardous location, Class I, Groups B
(except XFDN050), C, D; Class II,
Groups E, F, G. This special service
cast aluminum enclosure is supplied
with a wide, machined flanged cover
to prevent igniting outside atmospheres by arcing from inside the
enclosure. Front operable, the handle
padlocks in the Off position. Enclosures rated 600 amperes and above
have lift-off hinges for ease of assembly. UL and cUL File Number E71279.

187

Time/Current Curves, Dimension Sheets, Application Data

Cutler-Hammer

Molded Case Circuit Breakers
Enclosures

188

March 1999

Neutral Kits, Insulated and Groundable➇

Enclosure Only Catalog Numbers Selection Guide➀
Breaker Frame

Breaker
Enclosure
Ampere Range
NEMA Class

Catalog Number

Maximum
Enclosure Rating
(Amperes)

Main Lug Size
Cu/Al

Ground Lug Size
Cu/Al

Catalog
Number

Series C Breakers
GC, GHC, GD
2- and 3-Pole only
GHCGFEP➁
1-Pole Only

15-100

EHD, FD, FDB,
HFD, FDC

15-100

EHD, FD, FDB
HFD, FDC
FD, FDB, HFD, FDC,
ED, EDH, EDC

JD, JDB, HJD, JDC

15-50
60-225➃
125-225

125-250

1 Surface
3R
12
12K
4/4X, 5 St. Steel

SGDN100➁
RGDN100
JGDN100
DGDN100
WGDN100

1 Surface
1 Flush
3R
12
12K
4/4X, 5 St. Steel

SFDN100
FFDN100
RFDN100
JFDN100
DFDN100
WFDN100

7/9 Cast Aluminum
7/9 Cast Aluminum

XFDN050
XFDN225

1 Surface
1 Flush
3R
12
12K
4/4X, 5 St. Steel

SFDN225
FFDN225
RFDN225
JFDN225
DFDN225
WFDN225

1 Surface
1 Flush
3R
12
12K
4/4X, 5 St. Steel

SJDN250
FJDN250
RJDN250
JJDN250
DJDN250
WJDN250

JD, JDB, HJD, JDC

125-250

7/9 Cast Aluminum

XJDN250

KD, KDB, HKD, KDC, DK

125-400

1 Surface
1 Flush
3R
12
12K
4/4X, 5 St. Steel

SKDN400
FKDN400
RKDN400
JKDN400
DKDN400
WKDN400

KD, KDB, HKD, KDC, DK

125-400

7/9 Cast Aluminum

XKDN400

LD, LDB, HLD, LDC

300-600

1 Surface
3R
12
4/4X, 5 St. Steel

SLDN600
RLDN600
JLDN600
WLDN600

LD, LDB, HLD, LDC
MD, MDS

300-600
400-800

7/9 Cast Aluminum

XMCN800

MD, MDS, ND, NDC,
HND

400-1200

1 Surface
3R
12
4/4X, 5 St. Steel

SNDN1200
RNDN1200
JNDN1200
WNDN1200

7/9 Cast Aluminum

XNDN1200

15-100

1 Surface
1 Flush
3R
12
12K
4/4X

SFD100E
FFD100E
RFDN100E
JFDN100E
DFDN100E
WFDN100E

15-100

3R
12
12K
4/4X, 5 St. Steel

RFDN150
JFDN150
DFDN150
WFDN150

125-400

1 Surface
3R
12
4/4X, 5 St. Steel

SNDN1200
RNDN1200
JNDN1200
WNDN1200

FB-P

15-100

3R
12
12K
4/4X, 5 St. Steel

RFDN150
JFDN150
DFDN150
WFDN150

LA-P➆

70-400

1 Surface
3R
12
4/4X

SNDN1200
RNDN1200
JNDN1200
WNDN1200

NB-P

500-800

12
4/4X, 5 St. Steel

JNDPN800
WNDPN800

ND, HND, NDC

100

(1) 14–1/0

(1) 14–1/0

INK100

250

(1) 6–350 kcmil

(1) 4–300 kcmil

INK250

400

(1) 4–750 kcmil or
(2) 1/0–250 kcmil

(1) 4–300 kcmil

INK400

600

(2) 250–500 kcmil

(1) 4–300 kcmil

INK600

(3) 1/0 to 750 kcmil or
(4) 1/0 to 750 kcmil

(1) #6–250 kcmil

INK1200

1200

Raintight Hubs
Hub Diameter in Inches

Catalog Number

Small Hubs
For use with RGDN
and RFDN

All rainproof enclosures
30A through 400A are
shipped with plate over
cutout. Hubs are not
supplied with screws
on 30A through 400A
enclosures. Use screws
from plate.

3⁄4
1
1-1⁄4
1-1⁄2
2

DS075H1
DS100H1
DS125H1
DS150H1
DS200H1

2
2-1⁄2
3

R1H200
R1H250
R1H300

Large Hubs
For use with RJDN.
(RKDN has two cutouts)

R1HA

Required if using Type DS hubs
on RJDN and RKDN enclosures.

Breather and Drain, Hazardous Enclosures➄
Description

Compliance

Conduit
Opening

Catalog
Number

A Universal Breather/
Drain Fitting is installed
in the top of an enclosure to provide ventilation to minimize
condensation and in the
bottom to allow drainage
of accumulated condensation while maintaining
explosion proof integrity.

Type BD:
NEMA 7 – Class I, Groups
C, D; Class I, Zone 1, Group IIB
NEMA 9 – Class II, Groups F, G

1/2

XPBD2

Type DBB:
NEMA 7 – Class I, Groups B,
C, D; Class I, Zone 1, Group IIB
+ Hydrogen
NEMA 9 – Class II, Groups E,
F, G

1/2

XPDBB50

Earth Leakage Breakers➄
ELFD, ELHFD and ELFDC
(3-Pole Only)

Current Limit-R Breakers
FCL

LCL➅

TRI-PAC Breakers
➀ Enclosures only shown above; if an assembled enclosed
circuit breaker is required refer to Cutler-Hammer Satellite.
➁ Suitable for use with one-pole breaker base mounting plate kit.
QCCBP required.
➂ Enclosure must have date stamp later than 4-15-98.
➃ Maximum wire size: 4/0.
➄ Availability to be announced.
➅ LCL requires additional adapter plate 1223C06G01.
➆ LA-P requires additional adapter plate S/N 1223C06G02.
➇ If ground fault protection is required, contact regional satellite.

PG.74A.01.T.E

Cutler-Hammer

Molded Case Circuit Breakers
Enclosures

March 1999

189

Dimensions and Shipping Weights
Not to be used for construction purposes unless approved.
Inches and Millimeters.
NEMA 1 Surface Mounted
Catalog
Number

App.
Wt.
Lbs.

Max.
Amperes

Dimensions
A
Inches

Conduit Sizes, Inches
B

mm

Inches

C

D

E

E
mm

B

mm

Inches

mm

Inches

Inches

160
160
160
160
183

131⁄32
131⁄32
183⁄4
183⁄4
30

331
331
476
476
762

113⁄64
113⁄64
113⁄64
113⁄64
17⁄8

31
31
31
31
48

C

mm

SGDN100
SFDN100
SFDN150
SFDN225
SJDN250

12
12
15
15
31

100
100
150
225
250

171⁄2
171⁄2
231⁄4
231⁄4
3445⁄64

444 813⁄32
444 813⁄32
591 813⁄32
591 813⁄32
881 1059⁄64

214
214
214
214
227

69⁄32
69⁄32
69⁄32
69⁄32
713⁄64

SKDN400
SLDN600
SNDN1200

53
81
178

400
600
1200

3813⁄16
457⁄8
617⁄32

986 111⁄16
1165 145⁄16
1555 217⁄16

281
364
545

1015⁄16
123⁄8
1513⁄32

278 34
314 469⁄16
391 6127⁄32

869
1183
1571

29⁄32
129⁄32
131⁄32

58
48
50

1813⁄16
249⁄16
249⁄16
361⁄64
401⁄8

478 923⁄32
624 923⁄32
624 923⁄32
915 1215⁄64
1019 123⁄8

247
247
247
311
314

69⁄32
69⁄32
69⁄32
713⁄64
1015⁄16

160
160
160
183
278

131⁄32
183⁄4
183⁄4
30
34

331
476
476
762
869

155⁄64
155⁄64
155⁄64
17⁄8
215⁄16

47
47
47
48
75

⁄4, 1⁄2, 3⁄4, 1, 11⁄4, 11⁄2, 2, 21⁄2
⁄4, 1⁄2, 3⁄4, 1, 11⁄4, 11⁄2, 2, 21⁄2
1
⁄4, 1⁄2, 3⁄4, 1, 11⁄4, 11⁄2, 2, 21⁄2
1⁄4, 1⁄2, 3⁄4, 1, 11⁄4, 11⁄2, 2, 21⁄2
1⁄4, 1⁄2, 2, 21⁄2, 3
1

1

A

D

⁄ , ⁄ , ⁄ , 11⁄2, 2, 21⁄2, 3, 31⁄2
⁄ , ⁄ , ⁄ , 3, 31⁄2, 4

14 12 34
1
3
1
4
2
4

NEMA 1 Flush Mounted
FFDN100
FFDN150
FFDN225
FJDN250
FKDN400

12
15
15
32
53

100
150
225
250
400

⁄ , ⁄ , ⁄ , 1, 11⁄4, 11⁄2, 2, 21⁄2
⁄ , 1⁄2, 3⁄4, 1, 11⁄4, 11⁄2, 2, 21⁄2
⁄ , 1⁄2, 3⁄4, 1, 11⁄4, 11⁄2, 2, 21⁄2
⁄ , 1⁄2, 2, 21⁄2, 3
⁄ , 1⁄2, 3⁄4, 11⁄2, 2, 21⁄2, 3, 31⁄2

14 12 34

E

14
1
4
1
4
1
4

B

C

A

D

NEMA 12, 12K Dustproof
JGDN100
JFDN100
JFDN150
JFDN225
JJDN250
JKDN400
JLDN600
JNDPN800
JNDN1200

14
14
18
18
37
58
81
110
170

100
100
150
225
250
400
600
800
1200

1929⁄32
1929⁄32
2521⁄32
2521⁄32
3717⁄32
4111⁄16
485⁄16
6319⁄32
6319⁄32

506
506
652
652
953
1059
1227
1545
1545

827⁄32
827⁄32
827⁄32
827⁄32
119⁄16
113⁄4
1429⁄32
22
22

225
225
225
225
294
298
379
559
559

95⁄16
95⁄16
95⁄16
95⁄16
107⁄32
141⁄16
151⁄2
175⁄8
175⁄8

237
237
237
237
260
357
394
448
448

1817⁄32
1817⁄32
249⁄32
249⁄32
3549⁄64
3915⁄16
469⁄16
–
6127⁄32

471
471
617
617
909
1014
1183
–
1571

145⁄64
145⁄64
145⁄64
145⁄64
115⁄16
131⁄32
159⁄64
–
131⁄32

DGDN100
DFDN100
DFDN150
DFDN225
DJDN250
DKDN400

16
16
19
19
36
53

100
100
150
225
250
400

1929⁄32
1929⁄32
2521⁄32
2521⁄32
3717⁄32
4111⁄16

506 827⁄32
506 827⁄32
652 827⁄32
652 827⁄32
953 119⁄16
1059 113⁄4

225
225
225
225
294
298

95⁄16
95⁄16
95⁄16
95⁄16
107⁄32
141⁄16

237
237
237
237
260
357

–
–
–

–
–
–

–
–
–

–
–

–
–

–
–

43
43
43
43
49
150
49
–
50
–
–
–

E

A

C

D

ON
OFF

⁄4, 1⁄2, 3⁄4, 1, 11⁄4,11⁄2, 2, 21⁄2
⁄4, 1⁄2, 3⁄4, 1, 11⁄4,11⁄2, 2, 21⁄2
1
⁄4, 1⁄2, 3⁄4, 1, 11⁄4,11⁄2, 2, 21⁄2
1⁄4, 1⁄2, 3⁄4, 1, 11⁄4,11⁄2, 2, 21⁄2
– 1⁄4, 1⁄2, 2, 21⁄2, 3
– 1⁄4, 1⁄2, 3⁄4, 11⁄2, 2, 21⁄2, 3, 31⁄2
1

1

B

NEMA 3R Rainproof
RGDN100
RFDN100
RFDN150
RFDN225
RJDN250

14
14
19
19
40

100
100
150
225
250

1929⁄32
1929⁄32
2521⁄32
2521⁄32
371⁄2

458 827⁄32
458 827⁄32
603 827⁄32
603 827⁄32
891 119⁄16

225
225
225
225
294

95⁄16
95⁄16
95⁄16
95⁄16
107⁄32

237
237
237
237
260

1817⁄32
1817⁄32
249⁄32
249⁄32
3549⁄64

471
471
617
617
909

145⁄64
145⁄64
145⁄64
145⁄64
115⁄16

43
43
43
43
49

RKDN400
RLDN600
RNDN1200

60
84
175

400
600
1200

4111⁄16
485⁄16
6319⁄32

997 113⁄4
1227 1429⁄32
1615 22

298
379
559

141⁄16
151⁄2
175⁄8

357 3915⁄16
394 469⁄16
448 6127⁄32

1014
1183
1571

131⁄32
159⁄64
131⁄32

50
49
50

⁄4, 1⁄2, 3⁄4, 1, 11⁄4, 2, 21⁄2
⁄4, 1⁄2, 3⁄4, 1, 11⁄4, 2, 21⁄2
1⁄4, 1⁄2, 3⁄4, 1, 11⁄4, 2, 21⁄2
1⁄4, 1⁄2, 3⁄4, 1, 11⁄4, 2, 21⁄2
1
⁄4, 1⁄2, 2, 21⁄2, 3
1

E

1

⁄4, 1⁄2, 3⁄4, 21⁄2, 3, 31⁄2
⁄4, 1⁄2, 3⁄4, 3, 31⁄2, 4

C

1

ON

1

A

D
OFF

B

(Continued)
PG.74A.01.T.E

Cutler-Hammer

Molded Case Circuit Breakers
Enclosures

March 1999

Dimensions and Shipping Weights
Not to be used for construction purposes unless approved.
Inches and Millimeters.
NEMA 4/4X, 5 Stainless Steel
Catalog
Number

Max.
Amperes

App.
Wt.
Lbs.

Dimensions
B

Inches

mm

1929⁄32
1929⁄32
2521⁄32
2521⁄32
371⁄2
4111⁄16
485⁄16
6319⁄32

100
100
150
225
250
400
600
1200

16
16
20
20
39
60
88
185

WGDN100
WFDN100
WFDN150
WFDN225
WJDN250
WKDN400
WLDN600
WNDN1200

E

A

C

Inches

mm

Inches

mm

225
225
225
225
294
298
379
559

95⁄16
95⁄16
95⁄16
95⁄16
107⁄32
141⁄16
151⁄2
175⁄8

237
237
237
237
260
357
394
448

827⁄32
827⁄32
827⁄32
827⁄32
119⁄16
113⁄4
1429⁄32
22

506
506
652
652
953
1059
1227
1545

D

B

E

Inches

1817⁄32
1817⁄32
249⁄32
249⁄32
3549⁄64
3915⁄16
469⁄16
6127⁄32

mm

471
471
617
617
909
1014
1183
1571

Inches

mm

145⁄64
145⁄64
145⁄64
145⁄64
115⁄16
131⁄32
159⁄64
131⁄32

43
43
43
43
49
50
49
50

C

D
A

ON
OFF

NEMA 4/4X, 5 Stainless Steel
Catalog
Number

Overall
Enclosure

Breaker
Size
(Amperes)

A

B

15
251⁄2
381⁄2
443⁄4
503⁄4
65

50
100/225
250
400
600/800
1200➀

XFDN050
XFDN225
XJDN250
XKDN400
XMCN800
XNDN1200

CONDUIT POSITION NO.
3 G-MTG.
HOLES (3) J
1 2
B

Enclosure
Mounting
C

105⁄8
121⁄2
13
18
203⁄4
25

D

83⁄4
101⁄8
111⁄4
123⁄8
15
151⁄4

E

513⁄16
75⁄8
83⁄4
97⁄8
121⁄2
123⁄4

Conduit

F

9
101⁄2
111⁄2
10
22
231⁄2

G

12
20
28
45
40
50

H

⁄
⁄
⁄
⁄
⁄
⁄

13⁄4
2
21⁄8
3
4
61⁄2

1
2
12
12
1
2
1
2
1
2

Hinged Standard
Cover Conduit
I

J

31⁄4
31⁄4
31⁄2
4
5
43⁄4

Size

25⁄8
43⁄4
51⁄2
51⁄2
6
7

1

G-MTG.
HOLES (4)

1
1
1
2
3
3

2 3
G-MTG.
HOLES (4)

D
C

J

B

B

1

F-MTG.
A

F-MTG.
A

E-MTG.

34
70
120
180
460
600

2&7
2&7
2&7
1, 3 & 6, 8
1, 3 & 6, 8
1, 3 & 6, 8

11⁄4
2
21⁄2
3
4
4

J

1

Dia.
No.

CONDUIT POSITION NO.
CONDUIT POSITION NO.
1 2 3

I
8 7 6

Weight
(lbs.)
Location

F-MTG.
A

I

C
E-MTG.

D

Conduit Openings
Refer to outline dimensions for size and
location of standard conduit openings.
In addition, 1⁄2-inch openings are drilled
and tapped for breather and drain. Unless
ordered with breather and drain, these
openings are plugged. Refer to CutlerHammer for list price of breather and
drain.

D

C

Diagram 1

I

190

H H
E-MT

H

8 7 6

8

H

7 6

Diagram 3

Diagram 2

Circuit Breaker Enclosure Interpretation Data
2nd Field
Breaker Family

1st Field
Enclosure Type

NEMA 1
NEMA 3R
NEMA 12
NEMA 12K
NEMA 4, 4X, 5
NEMA 7/9

Flush
Surface

Stainless
Cast Al.

F
S
R
J
D
W
X

G-Frame
F-Frame
J-Frame
K-Frame
L-Frame
M-Frame
N-Frame

3rd Field
Maximum Ampacity

50
100
150
225
250
400
600
1200

NEMA
Enclosure

1st
Field

2nd
Field

R

FD

Breaker
Frame

3rd
Field

N*

150

Maximum
Ampacity

* “N” in this position indicates enclosure complies with 1981 NEC
gutter space requirement.

➀ Power cables must enter and leave from
opposite ends (through feed).

PG.74A.01.T.E

Cutler-Hammer

Molded Case Circuit Breaker
Standards

March 1999

Standards
Series C® molded case circuit breakers are designed to conform with
the following standards:

■

International Electrotechnical
Commission Recommendations
IEC 157-1, Circuit Breakers

Underwriters Laboratories, Inc.,
Standard UL 489, Molded Case
Circuit Breakers and Circuit
Breaker Enclosures

■

Japanese T-Mark Standard
Molded Case Circuit Breakers

■

South African Bureau of
Standards, Standard SABS 156,
Standard Specification for
Molded Case Circuit Breakers

■

Swiss Electro-Technical Association Standard SEV 157-1, Safety
Regulations for Circuit Breakers

■

■

National Electrical Manufacturers
Association Standards Publication
No. AB1-1993, Molded Case
Circuit Breakers

■

Australian Standard AS 2184,
Molded Case Circuit Breakers

■

■

British Standards Institution
Standard BS 4752: Part 1,
Switchgear and Control Gear
Part 1: Circit Breakers

Union Technique de I’Electricite
Standard NF C 63-120, Low Voltage Switchgear and Control Gear
Circuit Breaker Requirements

■

■

Canadian Standards Association
Standard C22.2 No. 5, Service
Entrance and Branch Circuit
Breakers

Verband Deutscher Elektrotechniker (Association of German
Electrical Engineers) Standard
VDE 0660, Low Voltage Switchgear and Control Gear, Circuit
Breakers

PG.74A.01.T.E

Conformance with these standards
satisfies most local and international
codes, assuming user acceptability
and simplified application.
Series C molded case circuit breakers equal or exceed Federal Specification Classification W-C-375b
requirements for the particular class
associated with the circuit breaker
frame being considered.

Further Information
Circuit Breaker
CD-ROM SA.74A.01.T.E

191

Cutler-Hammer

Miniature and Molded Case Circuit Breakers
Circuit Breaker Electronic Catalog

192

March 1999

Selection Data, Time Current Curves, Dimension Data

Navigation Chart of CD-ROM
SD - Selection Data

Title Page

TCC - Time-Current Curves
DS - Dimension Sheets

Main Menu
Quicklag
Miniature Circuit
Breakers UL/CSA
SD
TCC
DS

SPCL & SPHM
Supplementary
Protectors
UL-1077 & IEC

Series C
UL/CSA

Help

Series C
IEC 947-2

Universal
IEC 947-2

Replacement
Circuit Breakers

Power
Breakers

SD
TCC
DS

SD
TCC
DS

SD
TCC
DS

TCC

SD
TCC
DS

G

F

J

K

L

M

N

R

SD
TCC
DS

SD
TCC
DS

SD
TCC
DS

SD
TCC
DS

SD
TCC
DS

SD
TCC
DS

SD
TCC
DS

SD
TCC
DS

Motor
Circuit
Protectors

Earth
Leakage

Current
Limiting

Engine
Generator

Direct
Current

Mining
Service

Navy

Add-on
Ground
Fault

Circuit
Breaker
Enclosures

Fusible
Panelboard
Switches

SD
TCC
DS

SD
TCC
DS

SD
TCC
DS

SD
TCC
DS

SD

SD
TCC
DS

SD
TCC
DS

SD

SD

SD

DS

DS

System Requirements

Installation Instructions

■

Processor: 486 or faster
(Pentium or Pentium Pro recommended)

■

This is an autorun CD. Just insert this disk in the
CD-ROM drive and wait for it to launch.

■

Operating System: Microsoft Windows 95,
Windows 98, Windows NT 3.5, or Windows NT 4.0

■

Memory: 8 MB of available RAM
(16 MB recommended)

CD-ROM Installation Help Line: U.S.: 1-800-270-5134
Outside of the United States: Contact your local
Cutler-Hammer sales office.

■

Available Hard Disk Storage Space: 12 MB

■

Devices: a CD-ROM drive and a mouse

■

Monitor: minimum 640 x 480 resolution and 8-bit color
(256 colors)

If the CD is not included in this Product Guide, contact
Cutler-Hammer Fulfillment Center at 1-800-957-7050 and
ask for SA.74A.01.T.E.

PG.74A.01.T.E



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : Source W
Create Date                     : 2016:10:22 15:17:02+05:30
Modify Date                     : 2016:10:22 15:17:02+05:30
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Creator Tool                    : FrameMaker 5.5 PowerPC: LaserWriter 8 8.4.3
Producer                        : Acrobat Distiller 11.0 (Windows)
Format                          : application/pdf
Creator                         : Source W
Title                           : PG.74A.01.T.E
Document ID                     : uuid:9ca23048-05c8-4376-a6aa-b229848ede65
Instance ID                     : uuid:f2f18e16-91d9-43c5-baae-3102cddccaae
Page Count                      : 192
EXIF Metadata provided by EXIF.tools

Navigation menu