DE1-1
Loadcentres and Circuit Breakers
DE1 LOAD CENTRES
08/16
Square D QO®Loadcentres and Circuit Breakers Selection Guide
Contents Description Page
General Information
Product Illustrations/Features 3-4
QO®Breakers
•QO
®Standard Breakers and Tandem Circuit Breakers. 5
•QO
®Special Breakers (QO-CAFI, QO-DF, QO-GFI, QO-EPD, QO-HID, QO-AFI, QO-K, and
QO-HM) 6
Circuit Breaker Factory Installed Accessories 7
Circuit Breaker Wire Sizes 7
QO®Loadcentres
•QO
®Main Lugs Loadcentres - Type 1 Indoor 8
•QO
®'Stand Alone' Generator Panels 8
•QO
®Combination SE 'all-in-one' Generator Panels 8
•QO
®Main Breaker Loadcentres - Type 1 Indoor 9
•QO
®Main Lugs/Main Breaker Loadcentres - Type 3R Weatherproof
QO®Plug-on Neutral Loadcentres
10
11
•QO
®Recreational Vehicle Park (ServicePak® Panels) and Mobile Home and Trailer Loadcentres 12
Accessories
•QO
®Loadcentre and Circuit Breaker Accessories 13
•QO
®single phase loadcentre field installed neutral extension kits 14
Secondary Surge Suppressors and Surge Arresters 15
Dimensional Information
Enclosure Dimensions 16
HomeLine™ Loadcentres and Circuit Breakers Selection Guide
General Information
Product Illustrations / Features 17-20
Nomenclature Charts 21
HomeLine Breakers
Standard and Main Circuit Breakers 22
Tandem and Quad Circuit Breakersr 23
CAFI and DF 23
GFI, AFCI 24
Breaker Accessories 24
HomeLine Loadcentres
Indoor Single Phase Main Lug & Main Circuit Breaker Loadcentres 25
Outdoor Single Phase Main Lug & Main Circuit Breaker Loadcentres 26
HomeLine Fusible Loadcentre Inserts 27
HomeLine Loadcentre Accessories 29
Technical Information
Wiring Diagrams 32-33
Indoor Loadcentre Dimensions and Knockouts 34
Outdoor Loadcentre Dimensions and Knockouts 35
Loadcentres and Circuit Breakers
DE1 LOAD CENTRES
DE1-2 08/16
Federal Pioneer Stab-lok®Circuit Breakers Selection Guide
General Information
Features and Benefits 37
Stab-lok®Replacement Circuit Breakers and Accessories
Standard and Main Circuit Breakers 38
Stab-lok Breaker Accessories 39
Ground Fault Circuit Breakers and Spa Buddy 40
Arc-Fault Circuit Interrupters and Stab-lok Generator Panel - Replacement Breakers 41
Stab-lok®Replacement RV Panel Receptacle Kits
Recreational Vehicle Park Power Centre - Receptacle Kits 42
Stab-lok®Loadcentre Replacement Accessories
Stab-lok Loadcentre Replacement Accessories 43-44
DE1-3
QO® Loadcentres and Circuit Breakers
General Information
DE1 LOAD CENTRES
08/16
QO® Loadcentres
Pages: DE1-5 to DE1-14
Application: Residential, commercial, and
industrial
30 through 225 Amperes
Standards: CSA Certified under File
#LL-89066
Enclosures: Type 1 and 3R
Features: One piece, plated, shielded
copper bus (S-Series)
Split branch neutral with 3-1/0
“built in” branch neutral lugs
Combination Slot/Robertson
neutral, ground and trim screws
Additional ground bar provisions
Tr ims have automatic flush
adjustment
Accessories: Secondary Surge Arresters
Sub-Feed Lugs
Filler Plates (for branch and main
breakers)
Door Lock Kits
Neutral Lugs
QO single phase neutral
extension kits
DE1-4
QO® Loadcentres and Circuit Breakers
General Information
DE1 LOAD CENTRES
08/16
QO® Circuit Breaker
Branches: QO-CAFI - Combination Arc Fault Circuit Interrupter
QO-DF - Dual Function - CAFI+GFI (5mA)
QO - Plug-On Circuit Breakers
QO-GFI - Ground Fault Indication
QOT - Tandem Breakers
QO-EPD - Equipment Ground Fault Protection
QO-HID - High Intensity Discharge Lighting Systems
QO-K - Key Operated Breakers
QO-AFI - ARC Fault Circuit Interrupters
QO-HM - High Magnetics
Features: QWIK-OPEN® Circuit Breakers
VISI-TRIP® Indicator
Tandem Circuit Breakers feature two 1-Pole breakers
in the space of a 1-Pole QO breaker
QO2175SB SURGEBREAKER® Secondary Surge
suppressor
Shunt Trips, Auxiliary Switches, and Alarm Switches
are all available factory installed
For additional information,
– QO & QOB Miniature Circuit Breakers Catalogue 0730CT9801R1/08.
– QO-EPD Catalogue 0950CT9601
– Square D Series Ratings Guide Catalogue D0110AB9801EP R0
– Secondary Surge Arresters Catalogue 6671CT9701R9/06
DE1-5
QO® Loadcentres and Circuit Breakers
DE1 LOAD CENTRES
08/16
QO® Standard and Tandem Circuit Breakers
'10-30 ampere breakers are suitable for use with 60°C or 75°C conductors. 35-125 ampere breakers are suitable for use with 75°C conductors.
High magnetic trip breakers are recommended for applications where high initial inrush current may occur.
SWD (switching duty) rated. Suitable for switching 120Vac fluorescent lighting loads.
HACR type for use with air conditioning, heating and refrigeration equipment having motor group combinations and marked for use with HACR type
circuit breakers. HACR labelled one pole QO breakers not stocked. Order Only. Add suffix -5385.
Requires four spaces (#1-300 kcmil Al/Cu). Not suitable for use in 3-phase panel. Use only in single phase panel rated 150A or greater.
CSA Listed for use ahead of QO, QO-GFI, QO-EPD, QOT and QO-PL 10,000 AIR circuit breakers to permit their application at 22,000A fault level.
Plug-On Circuit Breakers - Amperes Interrupting Rating (AIR) in Amperes RMS Symmetrical
Ampere
Rating '
One Pole - 120/240Vac Two Pole - 120/240Vac
Common Trip
Three Pole - 240Vac
Common Trip
10,000 AIR
10 QO110 QO210 QO310
15 QO115◆▲ QO215QO315
15 QO115HM◆▲––
20 QO120◆▲ QO220QO320
20 QO120HM◆▲––
25 QO125 QO225QO325
30 QO130QO230QO330
35 QO135QO235QO335
40 QO140QO240QO340
45 QO145QO245QO345
50 QO150QO250QO350
60 QO160QO260QO360
70 QO170QO270QO370
80 QO280 QO380
90 QO290 QO390
100 QO2100 QO3100
110 QO2110
125 QO2125 No DC rating
150 QO2150◆▼
175 QO2175◆▼
200 QO2200◆▼
22,000 AIR
15 QO115VHQO215VH QO315VH
20 QO120VHQO220VH QO320VH
25 QO125VH QO225VH QO325VH
30 QO130VH QO230VH QO330VH
40 QO240VH QO340VH
50 QO250VH QO350VH
60 QO260VH QO360VH
70 QO270VH QO370VH
80 QO280VH QO380VH
90 QO290VH QO390VH
100 QO2100VH QO3100VH
110 QO2110VH
125 QO2125VH
150 QO2150VH❒◆▼
175 QO2175VH❒◆▼
200 QO2200VH❒◆▼
42,000 AIR
40
QOH240
45 QOH245
50 QOH250
60 QOH260
70 QOH270
80 QOH280
90 QOH290
100 QOH2100
110 QOH2110
125 QOH2125
65,000 AIR
15 QH115QH215 QH315
20 QH120QH220 QH320
25 QH125 QH225 QH325
30 QH130 QH230 QH330
Tandem (Dual) Circuit Breakers 10,000 AIR
Ampere Rating 'One Pole - 120/240Vac Two Single Pole Individual Trip - 120/240Vac
1 Space Required 2 Spaces Required
15 & 15
15 & 20
15 & 30
20 & 15
20 & 20
20 & 30
30 & 15
30 & 20
30 & 30
QO1515
QO1520
QO1530
QO2015
QO2020
QO2030
QO3015
QO3020
QO3030
Order Two QO1515 or QO2020 Circuit Breakers
and Handle Tie Catalogue # QOTHT.
Application Information
VISI-TRIP indication on all QO breakers.
QO, VISI-TRIP and QWIK-GARD are registered trademarks of Square D.
For more information consult Schneider Electric.
Accessories page DE1-11.
Add suffix 35 for 50°C calibration - 20% price adder.
1 Space Required
QO One Pole
1 Space Required
QO One Pole
Tandem
QO Three Pole
3 Spaces Required
QO Two Pole
2 Spaces Required
DE1-6
QO® Loadcentres and Circuit Breakers
DE1 LOAD CENTRES
08/16
QO® Special Breakers
Plug-On Circuit Breakers - Amperes Interrupting Rating (AIR) in Amperes RMS Symmetrical
One Pole
QO-GFI
QO-GFI
QWIK-GARD® circuit breakers provide overload and short circuit protection,
combined with Class A ground fault protection. Class A denotes a ground fault
circuit interrupter that will trip when a fault current to ground is 6 milliamperes
or more, for people protection. Do not connect to more than 250 feet of load
conductor for the total one-way run to prevent nuisance tripping.
Ampere
Rating '
One Pole
120Vac
Two Pole-
Common Trip
120/240Vac
Three Pole-
Common Trip
120/240Vac
10,000 AIR 22,000 AIR 10,000 AIR 10,000 AIR
15 QO115GFI QO115VHGFI QO215GFI QO315GFI
20 QO120GFI QO120VHGFI QO220GFI QO320GFI
25 QO125GFI QO125VHGFI QO225GFI
30 QO130GFI QO130VHGFI QO230GFI QO330GFI
40 QO240GFI QO340GFI
50 QO250GFI QO350GFI
60 QO260GFI
Suitable only for feeding 240Vac and 208Vac 2 wire loads.
Does not contain load neutral connection.
QO-EPD QO Circuit Breakers With 30 mA Equipment Ground Fault Protection
Ampere
Rating '
One Pole
120Vac
Two Pole-Common Trip
120/240Vac
10,000 AIR 10,000 AIR
15 QO115EPD QO215EPD
20 QO120EPD QO220EPD
25 QO125EPD QO225EPD
30 QO130EPD QO230EPD
40 QO240EPD
50 QO250EPD
60 QO260EPD
QO-K
Key operated QO circuit breakers are available in single pole construction and
can be mounted in any single pole space which will accept a standard QO.
These circuit breakers can be turned ON or OFF or to RESET with a special
key (Catalogue Number QOK10) included with the circuit breaker.
Ampere
Rating 'One Pole 120Vac
10,000 AIR
10 QO110K
15 QO115K
20 QO120K
30 QO130K
QO-HM QO circuit breaker with high magnetics to withstand higher inrush currents than
standard QO breaker.
Ampere
Rating One Pole 120Vac
10,000 AIR
15 QO115HM
20 QO120HM
QO Combination Arc-Fault Interrupter (CAFI)
QO Combination Arc-Fault Interrupter (CAFI) provides overload and short circuit protection,
plus both series and parallel type arc protection as required in 2015 CEC. Integrated with Time
Saver diagnostics, QO CAFI breaker improves circuit troubleshooting at the touch of a button.,
Circuit Breaker
Type
Ampere
Rating
1P 120 Vac
10K AIR
1 Space
Required
1P 120 Vac
22K AIR
1 Space
Required
2P 120/240 Vac
10K AIR
2 Space
Required
2P 120/240 Vac
22K AIR
2 Space
Required
QO Pigtail
Neutral CAFI
15 QO115CAFI QO115VHCAFI QO215CAFI* QO215VHCAFI*
20 QO120CAFI QO120VHCAFI QO220CAFI* QO220VHCAFI*
QO Plug-on
Neutral CAFI
15 QO115PCAFI QO115VHPCAFI
20 QO120PCAFI QO120VHPCAFI
* Rated for 120/240 ~60Hz, not for 208Y/120V
QO Dual Function Circuit Breaker
QO Dual Function (DF) breaker provides both combination arc-fault and ground-fault (5mA
classA) protection in a single compact device. Integrated with Plug-on Neutral and Time
Saver Diagnostics features, QO DF breaker offers maximum circuit protection and installation
flexibility.
Circuit Breaker Type Ampere
Rating
1P 120 Vac 10k AIR
1 Space Required
1P 120 Vac 22k AIR
1 Space Required
QO Dual Function
Circuit Breaker with
Pigtail Neutral
15 QO115DF QO115VHDF
20 QO120DF QO120VHDF
QO Plug-on Neutral
Dual Function Circuit
Breaker
15 QO115PDF QO115VHPDF
20 QO120PDF QO120VHPDF
QO-HID QO-HID Circuit Breakers -
For Use on High Intensity Discharge Lighting Systems
HID circuit breakers are for use on circuits feeding fluorescent and High Intensity Discharge
(HID) lighting systems such as mercury vapour, metal halide, or high pressure sodium. These
circuit breakers are physically interchangeable with QO circuit breakers.
Ampere
Rating '
One Pole
120/240Vac
Two Pole-Common Trip
120/240Vac
Three Pole-Common Trip
240Vac
10,000 AIR 10,000 AIR 10,000 AIR
15 QO115HIDQO215HID QO315HID
20 QO120HIDQO220HID QO320HID
25 QO125HID QO225HID QO325HID
30 QO130HID QO230HID QO330HID
40 QO140HID QO240HID
50 QO150HID QO250HID
Application Information
VISI-TRIP indication on all QO breakers.
QO, VISI-TRIP and QWIK-GARD are registered trademarks of Square D.
For more information consult Schneider Electric.
Note:
QO GFI, EPD, AFI, CAFI, and DF cannot be backfed.
Two Pole
QO-GFI
One Pole
QO-CAFI(PON)
One Pole
QO-DF(PON)
DE1-7
QO® Loadcentres and Circuit Breakers
DE1 LOAD CENTRES
08/16
'10-30 ampere breakers are suitable for use with 60°C or 75°C conductors,
35-60 ampere breakers are suitable for use with 75°C conductors.
SWD (switching duty) rated. Suitable for switching 120Vac fluorescent
lighting loads.
Combination AFI devices provide protection against both high-energy paral
lel arcing (same as existing branch/feeder AFCI’s) and low energy (5A)
series arcing.
Circuit Breaker Wire Sizes
Breaker
Type
Ampere
Rating '
Wire Size (AWG)
Aluminum Copper
QO
1 Pole
10-30 #14-8 #14-8
10-30 (2) #14-10
35-70 #8-2 #8-2
QO
2 & 3 Pole
10-30 #14-8 #14-8
35-70 #8-2 #8-2
80-125 #12-2/0 #12-2/0
QOT 15-20 #12-8 #14-8
QO-GFI
& QO-EPD
15-30 #12-8 #14-8
40-60 #12-4 #14-6
Circuit Breaker Factory Installed Accessories
Requires Additional Pole Space. Only one accessory per breaker. QO accessory terminals
for (2) #14-12 Cu. Accessories are not available for Q2, QOM1, or QOB-VH (110-150 A) circuit
breakers or QO molded case switches.
Factory
Installed
Accessories
Available
On Breaker Description
Add Suffix
To Breaker
Catalogue No.
120Vac
208Vac 1021
240Vac
Shunt TripQO 12Vac
24Vdc
12Vdc 1042
24Vac
Auxiliary
Switch
QO,-GFI,-EPD, “A” Contact 1200
“B” Contact 1201
Alarm Switch QO,-GFI,-EPD, 120Vac 2100
QO® Special Breakers
Main Breakers
Main Breaker
Frame Size Amperage kAIC Catalogue
Number
Lug Wire Size
AWG/KCMIL
Al or Cu
QOM1 '
30
10
QOM30L
#12-2/0
40 QOM40L
50 QOM50L
60 QOM60L
50
22
QOM50VHL
60 QOM60VHL
70 QOM70VHL
80 QOM80VHL
100 QOM100VHL
125 QOM125VHL
QOM2'
100
22
QOM2100VHL
#4-250
125 QOM2125VHL
150 QOM2150VHL
175 QOM2175VHL
200 QOM2200VHL
225 QOM2225VHL
Add suffix - 1021 for 240Vac shunt trip. Factory Installed Accessory
Do not exceed the load centre mains rating.
'Main Breakers include factory installed handle padlock attachment (padlock
QOM main circuit breaker in the 'off' position).
QO One Pole
with Shunt Trip
QOK Key
Operated
DE1-8
QO® Loadcentres and Circuit Breakers
DE1 LOAD CENTRES
08/16
QO® Main Lugs Loadcentres (1Ø - 3W)
Mains
Ampere
Rating
Number of Circuits
Loadcentre
Catalogue Number
Trim
Catalogue Number
Main Wire Size
Al or Cu
(AWG/MCM)
Box Size
(see page 16)
Standard
QO
Tandem
QO
30 1 2 QO1L30SIncluded 12-10 Al or 14-10 Cu 1
2 4 QO2L30SCIncluded 12-10 Al or 14-10 Cu 2
70 2 4 QO2L70S'Included 12-3 Al or 14-4 Cu 3
100
4 8 QO4L100SIncluded 8-1 4
6 12 QO6L100S/FIncluded 8-1 4
8 15 QO8L100S/FIncluded 8-1 4
12 24 CQO112L100GC Included 4-1 6
16 32 CQO116L100GC Included 4-1 7
125
24 48 CQO124L125GC Included 4 - 2/0 8
32 48 CQO132L125GC Included 4 - 2/0 9
40 48 CQO140L125GC Included 4 - 250 11
200 32 64 CQO132L200GC Included 4 - 250 11
40 80 CQO140L200GC Included 4 - 250 11
225 42 80 CQO142L225GC Included 4 - 300 12
60 80 CQO160L225GC Included4 - 300 14
QO® Main Lugs Loadcentres (3Ø - 4W)
Mains
Ampere
Rating
Number of Circuits
Loadcentre
Catalogue Number
Trim
Catalogue Number
Main Wire Size
Al or Cu
(AWG/MCM)
Box Size
(see page 16)
Standard
QO
Tandem
QO
100 3QO403L100S 'Included 12-1 Al or 14-1 Cu 5
125 1224 QO312ML1 QOC16UC 4 - 2/0 7
125 2040 QO320ML1 QOC24UC 4 - 2/0 8
200 2448 QO324ML2 QOC30UC 4 - 250 10
3060 QO330ML2 QOC30UC 4 - 250 10
225 4260 QO342ML2 QOC42UC 4 - 300 12
QO® Generator Panel (1Ø - 3W)
Mains
Ampere
Rating
Total Number of Circuits
Number of circuits available
for (generator) critical loads
Loadcentre
Catalogue Number
Main Wire Size
Al or Cu
(AWG/MCM)
Box Size
(see page 16)
Standard
QO
Tandem
QO
Standard
QO
Tandem
QO
30 4 8 CQO48M30DSGP #14-8 4
60 4 8 CQO48M60DSGP #8-2 4
30 18 36 QOGP3P3036 #14-8 6
60 18 36 QOGP3P6036 #8-2 6
QO® ‘all-in-one’ SE Generator Panels
200 40 80 18 36 QOGP3P604436200 #4-250 12
150 40 80 18 36 QOGP3P604436150 #4-250 12
125 40 80 18 36 QOGP3P604436125 #4-250 12
100 40 80 18 36 QOGP3P604436100 #4-250 12
'Service entrance approved.
Will not accept QO-GFI or QO-EPD breakers.
Maximum 20A QO-GFI breaker or AFI breaker.
Maximum 70A branch breaker.
Does not include a door. Order kit # QODK60-2.
Shunt trip feature not available on any 3Ø loadcentres.
Feed-thru lugs cannot be added in filed-use QO3125SL
to feed-thru to another loadcentre.
Bus on 2-8 cct loadcentres is one piece, solid aluminum.
Bus on 12-60 cct loadcentres is one piece, tin plated
copper
Neutral terminals, main and ground lugs on all devices
are Aluminum.
Application Information
All loadcentres are suitable for both flush or surface
mounting, unless suffixed:
- F - flush mounting only.
- S - surface mounting only.
All Type 1 loadcentres are approved for vertical, horizon
tal, or inverted mounting.
All 100A loadcentres are approved for 100A max. QO
branch circuit breakers.
All 125A loadcentres are approved for 125A max. QO
branch circuit breakers.
The maximum QO branch circuit breaker is 70 ampere
(single pole), 200 ampere (two pole) and 100 ampere
(three pole). Two pole QO breakers rated 150 - 200
ampere are restricted to Square D QO Single Phase load
center, Series G1.
Main lugs loadcentres cannot be field converted to ser
vice entrance approved, main breaker loadcentres.
QO is a registered trademark of Square D.
For more information, consult Schneider Electric.
GC includes ground bar combination surface/flush cover.
QO® Main Lugs Loadcentres - Type 1 Indoor
DE1-9
QO® Loadcentres and Circuit Breakers
DE1 LOAD CENTRES
08/16
QO® Main Breaker Loadcentres - Type 1 Indoor
Main Breaker Loadcentres (1PH - 3W)
Bus
Ampere Rating
Main Breaker
Amps
Number of Circuits
Loadcentre
Catalogue Number
Trim
Catalogue Number
Main Wire Size
Al/Cu (AWG/MCM)
Box Size
(see page 16)
Standard
QO
Tandem
QO
Main Breaker Factory Installed
100 60 12 24 CQO112M100C60 Included 4 - 1 6
100 100 12 24 CQO112M100C100 Included 4 - 1 6
100 60 16 32 CQO116M100C60 Included 4 - 1 7
100 100 16 32 CQO116M100C100 Included 4 - 1 7
125 60 24 48 CQO124M125C60 Included 4 - 2/0 8
125 100 24 48 CQO124M125C100 Included 4 - 2/0 8
125 100 32 54 CQO132M125C100 Included 4 - 2/0 9
125 125 32 54 CQO132M125C125 Included 4 - 2/0 9
125 100 40 54 CQO140M125C100 Included 4 - 2/0 11
125 125 40 54 CQO140M125C125 Included 4 - 2/0 11
Main Breaker Factory Installed
200 200 32 64 CQO132M200C Included 4 - 250 11
40 80 CQO140M200C Included 4 - 250 11
225 200 60 80 CQO160M200CIncluded4 - 250 14
Main Breaker Loadcentres (3Ø - 4W)
Bus
Ampere Rating
Main Breaker
Amps
Number of Circuits
Loadcentre
Catalogue Number
Trim
Catalogue Number
Main Wire Size
Al or Cu (AWG/MCM)
Box Size
(see page 16)
Standard
QO
Tandem
QO
Main Breaker Factory Installed (QO3100VH & QDL32200)
100 100 24 30 QO324MB100 QOC30UC 4 - 250 10
200 200 42 60 QO342MQB200 QOC342UQC 4 - 250 13
Does not include a door. Order kit # QODK60-2.Bus on all devices is one-piece, solid copper, standard.
Rated 200A maximum with Aluminum conductors and 225A
maximum with Copper conductors.
Neutral terminals, main and ground lugs on all devices are
Aluminum, standard.
NQ Service Entrance Main Breaker Panelboards
Main Rating Catalogue Number 1 or 3 Phase Space Factory Installed
Main Breaker Enclosure Width Trim Type
Standard QO Tandem QO
300A
NQSE142300F 1 phase 42 84 LAP26300MB 20” Flush
NQSE184300F 1 phase 84 120 LAP26300MB 20” Flush
NQSE142300S 1 phase 42 84 LAP26300MB 20” Surface
NQSE184300S 1 phase 84 120 LAP26300MB 20” Surface
400A
NQSE142400F 1 phase 42 LAL26400 20” Flush
NQSE342400S 3 phase 42 LAL36400 20” Surface
NQSE184400F 1 phase 84 LAL26400 20” Flush
NQSE372400S 3 phase 72 LAL36400 20” Surface
Application Information
All loadcentres are suitable for both flush or surface
mounting.
All Type 1 loadcentres are approved for vertical,
horizontal, or inverted mounting.
All 100A loadcentres are approved for 100A max. QO
branch circuit breakers.
All 125A loadcentres are approved for 125A max. QO
branch circuit breakers.
The maximum QO branch circuit breaker is 70 ampere
(single pole), 200 ampere (two pole) and 100 ampere
(three pole). Two pole QO breakers rated 150 - 200
ampere are restricted to Square D QO Single Phase load
center, Series G1.
Main Breaker loadcentres are approved for service
entrance use. The main breaker compartment can be
sealed and the main breaker can be locked.
QO-L main breakers are 10 kAIC rated, QO-VHL main
breakers are 22 kAIC rated.
QO is a registered trademark of Square D.
For more information, consult Schneider Electric.
DE1-10
QO® Loadcentres and Circuit Breakers
DE1 LOAD CENTRES
08/16
QO® Main Lugs/Main Breaker Loadcentres - Type 3R Weatherproof
Main Lugs Loadcentres (1Ø - 3W)
Bus
Ampere
Rating
Number of Circuits Main Wire Size
Al or Cu
(AWG/MCM)
Standard
QO
Tandem
QO
Loadcentre
Catalogue Number
Trim
Catalogue Number
Box Size
(see page 16)
70 2 4 QO2L70RB 'Included 12-3 Al or 14-4Cu 1RB
6 12 QO6L100RB Included 8-1 2RB
100 8 15 QO8L100RB Included 8-1 2RB
16 32 CQO116L100GRB Included 4-1 6RB
125 24 48 CQO124L125GRB Included 4-2/0 6RB
200 40 80 CQO140L200GRB Included 4-250 8RB
Main Lugs Loadcentres (3Ø - 4W)
Bus
Ampere
Rating
Number of Circuits Main Wire Size
Al or Cu
(AWG/MCM)
Box Size
(see page 16)
Standard
QO
Tandem
QO
Loadcentre
Catalogue Number
Trim
Catalogue Number
100 3 QO403L100RB 'Included 12-1 Al or 14-1 Cu 3RB
125 12 24 QO312ML1RB Included 4-2/0 4RB
125 20 40 QO320ML1RB Included 4-2/0 5RB
200 30 60 QO330ML2RB Included 4-250 7RB
225 42 60 QO342ML2RB Included 4-300 9RB
Main Breaker Loadcentres (1Ø - 3W)
Bus
Ampere Rating
Main
Breaker
Amps
Number of Circuits
Loadcentre
Catalogue Number
Trim
Catalogue Number
Main Wire Size
Al/Cu
(AWG/MCM)
Box Size
(see page 16)
Standard
QO
Tandem
QO
Main Breaker Factory Installed
100 60 8 16 CQO18M100RB60 Included 4 - 1 4RB
100 100 16 32 CQO116M100RB100 Included 4 - 1 6RB
125 100 24 48 CQO124M125RB100 Included 4 - 2/0 6RB
Main Breaker Factory Installed
200 200 40 80 CQO140M200RB Included 4-250 8RB
Non-Metallic Enclosure (1Ø - 3W) Type 3R
Bus
Ampere Rating
Number of Circuits Loadcentre
Catalogue
Number
Trim
Catalogue Number
Main Wire Size
Al/Cu
(AWG/MCM)
Box Size
(see page
15)
Standard
QO
Tandem
QO
60 2 4 CQO24L60NRNM Included #14-4 / #14-4 1NM
QO Hot Tub / Pool / Spa Pack
20 to 60 amp non-metallic
2 pole QOGFCI factory
installed into a
type 3R enclosure
CQOE220GFINM
CQOE230GFINM
CQOE240GFINM
CQOE250GFINM
CQOE260GFINM
Maximum 20 A QO-GFI breaker.
60 amp, 2 wire 240V only. Not for hot tubs with neutral connection.
'Service Entrance approved.
Not rated for 22k AIC.
Bus on 2-8 cct loadcentres is one-piece, solid aluminum. (Excluding CQO18M100RB.)
Bus on 8-42 cct, S-Series loadcentres is one-piece, solid copper.
Neutral terminals, main and ground lugs on all devices are Aluminum.
Application Information
All 100A loadcentres are approved for 100A max. QO
branch circuit breakers.
All 125A loadcentres are approved for 125A max. QO
branch circuit breakers.
The maximum QO branch circuit breaker is 70 ampere
(single pole), 200 ampere (two pole) and 100 ampere
(three pole). Two pole QO breakers rated 150 - 200
ampere are restricted to Square D QO Single Phase load
center, Series G1..
Main Breaker loadcentres are approved for service
entrance use. The main breaker compartment can be
sealed and the main breaker can be locked.
Main lugs loadcentres cannot be field converted to ser
vice entrance approved, mainbreaker loadcentres.
Weatherproof Loadcentres are supplied with main entry
hole cut in top endwall and closing cap (BCAP) installed.
Hole accepts 3/4 in. to 2 in. hubs. Gasket not required.
QO is a registered trademark of Square D.
DE1-11
QO® Loadcentres and Circuit Breakers
DE1 LOAD CENTRES
08/16
QO® Plug-on Neutral Loadcentres
QO Plug-on Neutral Loadcentres
Mains Rating
Amps
Number of Circuits
Loadcentre
Catalogue Number
Main Wire Size
Al/Cu
(AWG/MCM)
Box Size
(see page 16)
Standard
QO
Tandem
QO Trim
Main Lugs Loadcentres (1Ø - 3W)
Indoor
125 24 47 CQO124L125GCPON Included 4 - 2/0 8
Main Breaker Loadcentres (1Ø - 3W)
100 24 47 CQO124M125C100PON Included 4 - 2/0 8
100 30 60 CQO130M225C100PON Included 4 - 2/0 10
100 42 80 CQO142M225C100PON Included 4 - 2/0 12
200 42 80 CQO142M200CPON Included 4 - 250 12
200 60 80 CQO160M200CPON* Included 4 - 250 14
Outdoor 100 24 47 CQO124M125RB100PON Included 4 - 2/0 6RB
* Does not include a door. Order kit # QODK60-2.
'Plug-on Neutral loadcentres accept both pig-tail and Plug-on Neutral breakers
DE1-12
QO® Loadcentres and Circuit Breakers
DE1 LOAD CENTRES
08/16
QO® Recreational Vehicle Park Loadcentres (ServicePak®)
QO® Mobile Home and Trailer Loadcentres
Provide electrical power to individual recreational vehicle park sites.
Each receptacle protected by appropriate GFI or Standard QO® circuit breaker.
All receptacles and circuit breakers included.
10,000 RMS Symmetrical Ampere short circuit current rating.
All enclosures are rainproof.
No neutral bonding provisions.
Loop-Feed provisions.
Type 3R weatherproof.
Optional configurations not available.
Pedestal is factory installed only.
Recreational Vehicle Park Loadcentres (ServicePak® Panels)
Power
Outlet
Config.
Main Wire Size
Ampere Rating Canada
Catalogue No.
(AWG/MCM) Box Size
(see page 16)Mains Sub-feed Spaces Service Series Al Cu
Underground or Overhead Loop-Feed Terminals - Non-Pedestal Mounted
40 40 2 A 1Ø2W QO2RV40A
QO2RV40AG E01 14 - 6 12 - 6 RVP1
50 50 2 B 1Ø2W
QO2RV50B
QO2RV50BG
QO2RV50BGFI
E01 14 - 6 12 - 6 RVP1
75 75 3 C 1Ø2W
QO3RV75C
QO3RV75CG
QO3RV75CGFI
E01 14 - 1 12 - 1 RVP2
Underground Loop-Feed Terminals - Pedestal Mounted
50 200 2 B 1Ø2W
QO2RVP50B
QO2RVP50BG
QO2RVP50BGFI
E01 6 - 250 RVP1+Pedestal
75 200 3 C 1Ø2W
QO3RVP75C
QO3RVP75CG
QO3RVP75CGFI
E01 6 - 250 RVP2+Pedestal
100 200 4 D 1Ø3W
QO4RVP100D
QO4RVP100DG
QO4RVP100DGFI
E02 6 - 250 RVP2+Pedestal
Power Outlet Configurations - Description
Configuration
AB CD
Receptacles Catalogue Number Suffix Canada Catalogue No.
configuration A
non-pedestal
STANDARD DEVICE - 2xQO115 + 2x 15A 120v recpt
G = 2xQO115GFI factory installed
QO2RV40A
QO2RV40AG
configuration B
non-pedestal
STANDARD DEVICE - 1xQO115+ 1xQO130 + 1x15A,1x30A 120v recpt
G = 1xQO115GFI & 1xQO130 factory installed
GFI = 1xQO115GFI & 1XQO130GFI factory installed
QO2RV50B
QO2RV50BG
QO2RV50BGFI
configuration C
non-pedestal
STANDARD DEVICE - 1xQO115+ 2xQO130 + 1x15A, 2x30A 120v recpt
G = 1xQO115GFI & 2xQO130 factory installed
QO3RV75C
QO3RV75CG
configuration B
pedestal
STANDARD DEVICE - 1xQO115+ 1xQO130 + 1x15A,1x30A 120v recpt
G = 1xQO115GFI & 1xQO130 factory installed
GFI = 1xQO115GFI & 1XQO130GFI factory installed
QO2RVP50B
QO2RVP50BG
QO2RVP50BGFI
configuration C
pedestal
STANDARD DEVICE - 1xQO115+ 2xQO130 + 1x15A, 2x30A 120v recpt
GFI = 1xQO115GFI & 2xQO130GFI factory installed
QO3RVP75C
QO3RVP75CGFI
configuration D
pedestal
STANDARD DEVICE - 1xQO115+ 1xQO130 + 1xQO250
+ 1x15A, 1x30A 120v recpt & 1x50A 120/240v recpt
G = 1xQO115GFI & 1xQO130 & 1xQO250 factory installed
GFI = 1xQO115GFI & 1x10130GFI & 1xQO250 factory installed
QO4RVP100D
QO4RVP100DG
QO4RVP100DGFI
Mobile Home and Trailer Loadcentres
Mains Ampere
Rating Spaces Service
Catalogue
Number Series
Main Wire Size (AWG/MCM) Box Size
(see page 16)Al Cu
Main Lugs Loadcentres
30 2 1Ø2W QO2L30TTS ‡ G01 12 - 10 14 - 10 MH1
50 2 1Ø2W QO24L50TTS G01 14 - 6 MH2
70 2 1Ø3W QO24L70TS G01 12 - 3 14 - 4 MH2
100 6 1Ø3W QO612L100TF/S † G01 4 - 1 MH3
100 6 1Ø3W QO612L100DTF/S † G01 4 - 1 MH3
Non-pedestal devices are supplied with main entry hole cut in top endwall and have closing cap (BCAP) installed. Hole accepts 3/4 in. to 2 1/2 in. hubs. Gasket not required.
Non-pedestal devices have provisions to field install a Type “B” bolt on hub on the bottom endwall. For bottom feed from a conduit riser, order Type “B” hub and two mounting screws P/N:
8002505501; and two hex nuts, P/N: 2340102000.
For pedestal devices, a stabilizer foot is available for use in unstable ground, P/N: HNPSF.
‡Will not accept QO-GFI circuit breakers.
Use #10 maximum size wire for QO-GFI circuit breakers.
70A Max. branch circuit breaker and 70A Max. back fed main circuit breaker.
T T
T
T
T
Application Information
All Servicepak® Panels have their breakers and
receptacles factory installed and prewired.
Mobile Home and Trailer Loadcentres do not come with
factory installed breakers. Order separately.
Servicepak® Panels and Mobile Home and Trailer Load
centres are not suitable for use as service equipment.
All Servicepak® devices are set up for Loop-fed,
therefore, there are 2 wires per phase, neutral and
equipment ground.
Servicepak® devices are suitable for surface mounting
only.
Power Outlet Configurations, other than those shown
above, are not available.
Servicepak® is a Registered Trademark of Square D.
For more information, consult Schneider Electric.
DE1-13
QO® Loadcentres and Circuit Breakers
DE1 LOAD CENTRES
08/16
Accessories
Description Catalogue Number
Handle Attachments
Handle Tie: Converts any two adjacent 120/240Vac single pole QO breakers to independent trip two pole.......................... QO1HT
Converts any two adjacent 120/240Vac single pole side-by-side Tandem breakers to independent trip two pole QOTHT
Handle Lock-Off: Clamp for holding QO single pole handle in “ON” or “OFF” position.................................................................... QO1LO
Clamp for holding QO, either 1, 2 or 3-pole breaker handles in “ON” or “OFF” position...................................... HLO1
Handle Padlock Attachment: For padlocking single pole QO breaker in “ON” or “OFF” position
Loose Attachment QOHPL
Fixed Attachment QO1PA
For padlocking single pole side-by-side QO Tandem breaker in “ON” or “OFF” position.... ................................. QOTHPA
For 2 and 3-pole QO breakers which require padlocking in either “ON” or “OFF” position
Loose Attachment........................................................................................................................................ . QO1HPL
Fixed Attachment... ..................................................................................................................................... .. QO1PL
For padlocking QOM main circuit breakers in “OFF”...............................................................50-125A... ........... . QOM1PA
150-225A... ...................................................................................................................................................... .... QOM2PA
For padlocking 2-Pole QO-GFI in either “ON” or “OFF” position.......... .............................................. .................. GFI2PA
Mechanical Interlock Attachment: For interlocking the handles of two 2-pole or one 2-pole and one 1-pole QO breakers mounted side-by-side
so that only one breaker can be “ON” at a time..... .............................................................................................. QO2DTI
Sub-feed lugs 125 ampere two pole plug-on – 2 spaces required (#12-2/0 Al/Cu)..................................................................... QO2125SL
125 ampere three pole plug-on – 3 spaces required (#12-2/0 Al/Cu).................................................................. QO3125SL
Filler Plates Fills branch breaker openings in cover................................................................................................................. QOFP
Fills QOM1 main breaker opening in cover...............................................................100-125A........................... . QOM1FP
Fills QOM2 main breaker opening in cover...............................................................150-225A........................... . QOM2FP
Fills main breaker opening in 3Ø covers (S-Series)............................................................................................. KFP
Lock Kits Converts door latch from spring catch to lock type .............................................................................................. PK6FL
Neutral / Ground Lugs Field installed for #12 to 2 Al or #14 to 4 Cu wire ................................................................................................ LK70AN
Field installed for #6 to 2/0 Al/Cu wire.................................................................................................................. LK100AN
Field installed for #14 to 2/0 Al/Cu wire................................................................................................................ LK125AN
Field installed for #2 to 3/0 Al/Cu wire.................................................................................................................. LK150AN
Field installed for #4 to 300 MCM Al/Cu............................................................................................................... LK225AN
Neutral Extension kits Field installed on 1ph QO loadcentres See page DE1-12
Ground Bar Kits Standard PK15GTA with a #1 to 4/0 Cu/Al Lug................................................................................................... . PK15GTAL
Standard PK18GTA with a #1 to 4/0 Cu/Al Lug................................................................................................. ... PK18GTAL
Standard PK23GTA with a #1 to 4/0 Cu/Al Lug................................................................................................... . PK23GTAL
Insulator Kit for PK9GTA thru PK27GTA.. .......................................................................................................... .. PKGTAB
Miscellaneous QO main breaker barrier. .................................................................................................................................. ... 4055952201
Retaining Kit: Secures circuit breaker to interior when used as a back-fed main.
For use on QO6L100S/F, RB and QO8L100S/F, RB Loadcentres. ................................................................... ... PK2MB
Secures circuit breaker to interior when used as a back-fed main. For 3Ø Loadcentres (S-Series)................... . PK3MB
Cover Sealing Strap: Provides means of sealing trim mounting screws on QO load centre covers.. ................................................. ... QO1SE
Joint Compound For use on plug-on connectors only. Recommended for use whenever QO plug-on breakers are removed and
reinstalled for any reason. 57g container ............................................................................................................ . PJC7201
Touch–up Paint Aerosol spray paint can – ASA 49 ....................................................................................................................... W469X83
PK2MB
PK3MB
PK6FL HLO-1
QO1HPL
QO1PL
QO2DTI
QO1LO
PKGTAB
QOFP
QO1PA
QOSAMK
QOTHPA
QO1HT
HLO1
Application Information
QO is a registered trademarks of Square D.
For more information consult Schneider Electric.
DE1-14
QO® Loadcentres and Circuit Breakers
DE1 LOAD CENTRES
08/16
QO® Single Phase Loadcentre - Field Installed Neutral Extension Kits
QO neutral kit - customer opportunities
Increased installation flexibility
Enhanced retro-fit opportunities
QO neutral kit - advantages
Multiple length kits available
Kit includes a left and right side neutral bar
Left side or right side installation option
Loadcentre
catalogue number
Reference
neutral kit(s)*
CQO124L125GC 1
CQO124L125GRB 1
CQO124M125C60 1
CQO124M125C100 1
CQO124M125RB100 1
CQO132L125GC 1
CQO132L200GC 1
CQO132M125C100 1
CQO132M125C125 1
CQO132M125C60 1
CQO132M125C70 1
CQO132M200C 1
CQO140L125GC 2
CQO140L200GC 2
CQO140L200GRB 2
CQO140M125C100 2
CQO140M125C125 2
CQO140M150C 2
CQO140M200C 2
CQO140M200RB 2
CQO142L225GC 1 or 3
CQO160L225GC 2 , 3 or 4
CQO160M200C 2 , 3 or 4
CQO124M60CD 1
CQO124M100CD 1
CQO132M100CD 1
CQO132M125CD 1
CQO140M200CD 2
CQO112L100GC –
CQO116L100GC –
CQO116L100GRB –
CQO116M100C60 –
CQO116M100C100 –
CQO116M100RB100 –
CQO18M100RB60 –
CQO112M100C60 –
CQO18M100RB100 –
Loadcentre
catalogue number
Reference
neutral kit(s)*
* Neutral kit reference number description
Reference neutral kit(s) Neutral kit catalogue number Neutral kit description
1 QONK1 14 neutral ports x 2
2 QONK2 22 neutral ports x 2
3 QONK3 34 neutral ports x 2
4 QONK4 41 neutral ports x 2
Neutral kit is not available
*Installing the Neutral Bar Extensions
When installing the QO neutral bar extension kits, circuit breaker mounting spaces need to be left
open below the neutral extension kits for ground fault interrupters, arc fault interrupters and the larger
amperage branch circuit breakers rated 150–200 A that would extend beyond the neutral bars.
These circuit breaker types will not fit over the OQ neutral extension kit bars.
Application Information
For more information, contact our Customer Information Centre @ 1-800-565-6699.
DE1-15
QO® Loadcentres and Circuit Breakers
DE1 LOAD CENTRES
08/16
Secondary Surge Suppressors and Surge Arresters
SURGEBREAKER PLUS®
Suitable for use in service entrance locations.
Meets requirements of CSA C22.2 No. 8, UL 1449, 3rd Edition, ANSI/IEEE C62.41
and cULus Listed.
AC line protection.
Four line telephone protection.
Two l ine coaxial protection.
Suitable for indoor applications only.
Flush or surface mounting.
LED status indicator.
Modular design with optional accessories.
Single Phase Three Wire – 120/240 Vac
Description Catalogue Number
Surgebreaker Plus SDSB80111C
SURGEBREAKER™ Secondary Surge Arrester
Suitable for use in service entrance locations.
Meets CSA C22.2 No. 8, CSA C233.1, ANSI/IEEE C62.11.
QO2175SB for QO load centers and combination devices, NQOD panelboards.
Plug–on design requires two pole spaces.
LED indicates operational status.
Description
Catalogue
Number
QO Surgebreaker
cULus Listed
Secondary Surge Arrester
150Vac line–to–ground maximum
QO2175SB
Hard–Wired Secondary Surge Arresters
Suitable for use in service entrance locations.
cULus Listed Secondary Surge Arresters.
Meets CSA C233.1, ANSI/IEEE C62.11.
Suitable for indoor and outdoor applications.
LED indicates operational status.
Description
Catalogue
Number
SECONDARY SURGE ARRESTER
For 1Ø systems.
150Vac phase–to–ground maximum.
SDSA1175
SECONDARY SURGE ARRESTER
for 3Ø systems.
600Vac phase–to–ground
maximum.
SDSA3650
Catalogue Number QOSAMK required for installation in QO loadcentres (see page
DE1–11 for diagram).
Do not use on ungrounded systems. Systems must be
solidly grounded.
Application Information
For more information, please refer to catalogue No. 6671CT9701.
QO2175SB
SDSA3650
SDSA1175
SDSB80111C
DE1-16
QO® Loadcentres and Circuit Breakers
DE1 LOAD CENTRES
08/16
Enclosure Dimensions
Type 1 QO Loadcentre Enclosures Type 3R QO Loadcentre Enclosures
Type 1
Box Size
Height
(in./mm)
Width
(in./mm)
Depth
(in./mm)
Type 3R
Box Size
Height
(in./mm)
Width
(in./mm)
Depth
(in./mm)
15.50/140 3.00/76 3.50/89 1NM 9.80/245 6.5/162.53.9/97.5
26.75/171 3.75/95 3.00/76 1RB 9.50/241 5.00/127 4.00/102
39.25/235 4.75/121 3.25/83 2RB 12.75/324 9.00/229 4.25/108
4 12.75/324 9.00/229 3.75/95 3RB 13.00/330 6.75/171 4.00/102
5 13.25/377 6.00/152 3.50/89 4RB 19.00/483 14.25/362 4.50/114
6 15.00/381 14.25/362 3.75/95 5RB 22.00/559 14.25/362 4.50/114
7 18.00/457 14.25/362 3.75/95 6RB 22.25/565 14.25/362 4.50/114
8 21.00/533 14.25/362 3.75/95 7RB 30.00/762 14.25/362 4.50/114
9 26.25/667 14.25/362 3.75/95 8RB 34.00/864 14.25/362 4.50/114
10 30.00/762 14.25/362 3.75/95 9RB 38.00/965 14.25/362 4.50/114
11 34.00/864 14.25/362 3.75/95
12 38.00/965 14.25/362 3.75/95
13 40.00/1016 14.25/362 3.75/95
14 41.25/1048 14.25/362 3.75/95
Recreational Vehicle Park Loadcentres Mobile Home and Trailer Loadcentres
Box
Size
Height
(in./mm)
Width
(in./mm)
Depth
(in./mm)
Box
Size
Height
(in./mm)
Width
(in./mm)
Depth
(in./mm)
RVP1 8.50/216 7.75/197 5.80/147 MH1 6.72/171 3.81/97 3.00/76
RVP2 16.40/417 7.75/197 5.80/147 MH2 9.30/236 4.80/122 3.19/81
Pedestal 50.90/129 7.60/193 3.50/89 MH3 12.57/319 8.88/226 3.80/97
Application Information
Dimensions for approximate only.
Do not use for construction.
DE1-17
Canadian HomeLine®Circuit Breakers and Loadcentres
General Information
DE1 LOAD CENTRES
08/16
Canadian HomeLineSingle Phase Loadcentres
Pages: DE1-17 to DE1-34
Application: Residential, Light Commercial
30 through 225 Amperes
Standards: CSA Certified under File
#LL-89066
Enclosures: Type 1 and 3R
Features: One piece, plated, shielded
aluminum bus
Split branch neutral with 3-1/0
built inbranch neutral lugs
Combination Slot/Robertson neu-
tral, ground and trim screws
Additional ground bar provisions
Trims have automatic flush
adjustment
Fusible loadcentre inserts
(HFLCI)
Accessories: Secondary Surge Arresters
Sub-Feed Lugs
Filler Plates (for branch and main
breakers)
Door Lock Kits
Neutral Lugs
Neutral extension kits
Canadian HomeLine™ Circuit Breakers and Loadcentres
Product Description
DE1 LOAD CENTRES
DE1-18
08/16
The Residential Solution for Canadian Electrical Contractors
HomeLinecircuit breaker loadcentres from Schneider Electric are CSA
certified panelboards. They are designed to meet residential requirements to
protect electrical systems, equipment, and people.
Features
Indoor (NEMA Type 1), Main Breaker, 12 to 60 spaces
Single phase, 120/240V
200A maximum tin plated aluminum bus
60 spaces, 120 circuits max
Short circuit rating
kstandard 22kAIC – main breaker (50A thru 200A)
kseries ratings up to 100kAIC
Distributed neutral bar design
Robertson/Slot neutral, ground and trim screws
Shielded bus bar
Appliance white combination flush/surface mount trim
Automatic flush trim adjustment with shutter type twistouts
Top or bottom feed
Multiple horizontal and vertical ground bar mounting positions
Straight in wiring for main and branch wiring
Removable interiors
Tangential main knockouts
Provision for optional door lock
Welded box construction
Indoor (NEMA Type 1), Main Lug, 2 to 42 spaces
Single phase, 120/240V
225A maximum tin plated aluminum bus
42 spaces, 84 circuits max
Short circuit rating
kstandard 10kAIC – main lug
kseries ratings up to 100kAIC
Robertson/Slot neutral, ground and trim screws
2 to 6 space single row loadcentres, ASA49 grey
Top or bottom feed
Welded box construction
HomeLine Fusible Loadcentre Inserts (HFLCI)
Indoor (NEMA Type 1), Main Lug, 12 spaces
Single phase, 120/240V
125A maximum tin plated aluminum bus
12 spaces, 24 circuits max
Short circuit rating
kstandard 10kAIC
kseries ratings up to 100kAIC
Robertson/Slot neutral, ground and trim screws
Architectural white surface mount trim with door
HomeLineMain Breaker Loadcentre
Flush Cover
Canadian HomeLineCircuit Breakers and Loadcentres
General Information and Application Data
DE1 LOAD CENTRES
DE1-19
08/16
Outdoor (NEMA Type 3R), Main Breaker,
8 to 20 spaces
Single phase, 120/240V
200A maximum tin plated aluminum bus
20 spaces, 40 circuits max
Short circuit rating
kstandard 22kAIC – main breaker
kseries ratings up to 100kAIC
Distributed neutral bar design
Robertson/Slot neutral, ground and trim screws
Shielded bus bar
Side hinged door
Welded, galvanealed steel, painted ASA49 grey enclosure
Gasketless rain hubs – 0.75to 2.5
Stainless steel locking hasp
Outdoor (NEMA Type 3R), Main Lug,
2 to 12 spaces
Single phase, 120/240V
125A maximum tin plated aluminum bus
12 spaces, 24 circuits max
Short circuit rating
kstandard 10kAIC – main lug
kseries ratings up to 100kAIC
Robertson/Slot neutral, ground and trim screws
Welded, galvanealed steel, painted ASA49 grey enclosure
Gasketless rain hubs – 0.75to 2.5
Stainless steel locking hasp
RB Device
Bolt-On Hubs
Canadian HomeLine™ Circuit Breakers and Loadcentres
General Information and Application Data
DE1 LOAD CENTRES
DE1-20
08/16
Main breakers, branch breakers and surge suppressors
CSA File # LL-89066
Accepts 60/75C wire up to 40A, 75C wire over 40A
HACR rated
SWD rating on 115A and 20A breakers
1-pole and 2-pole
Standard – 1per pole
Twin – 1/2per pole
Quad – 1/2per pole
Main breakers
k30A thru 225A
Branch breakers
15A thru 200A
Optional high magnetic on 115A and 20A breakers
Subfeed lugs
k125A or 225A
Arc-fault circuit interrupters – 20A max
Combination arc-fault circuit interrupters – 20A max
kSenses series and parallel arcing
Ground fault circuit interrupters – 50A max
k5mA Class A
k30mA equipment protective devices
kSpa packs
Accessories
khandle lock offs
khandle ties
kbranch filler plates
Plug-in surge suppressors
kElectronic MOV technology
kPlug-in or knockout mounted
Branch Circuit Breakers
CHOM 1-Pole
1 space required.
CHOM 2-Pole
2 spaces required.
CHOMT 1-Pole Tandem
1 space required.
CHOMT Quad Circuit Breaker
2 spaces required.
CHOM 1-Pole GFI
1 space required.
CHOM 2-Pole GFI
2 space required.
CHOM-AFI
1 space required.
QOM2 Frame Size
QOM1 Frame Size
10,000 AIR
CHOM 1-pole, 15–50 A
2-pole, 15–200 A
CHOMT 1-pole, 15–30 A
2-pole, 15–50 A
CHOM-GFI 1-pole, 15 & 20 A
2-pole, 15, 20, 30, 40, 50 A
CHOM-AFI 1-pole, 15 & 20 A
CHOM-CAFI 1-pole & 2 pole, 15 & 20 A
CHOM-DF 1-pole, 15 & 20 A
Canadian HomeLineCircuit Breakers and Loadcentres
Product Description
DE1 LOAD CENTRES
DE1-21
08/16
Notes:
1. CHOM 1pole - 1" wide, 1 space required.
2. CHOM 2pole - 2" wide, 2 spaces required.
3. CHOMT 1pole tandem - 1" wide, 1 space required,represents two 1pole circuit breakers, i.e. CHOMT1515.
4. CHOMT 2pole tandem quad - 2" wide, 2 spaces required, represents two 1pole outer poles and one 2pole inner circuit breaker with common trip,
i.e. CHOMT1515220.
Canadian Catalogue Number logic
HomeLineLoadcentres
Number Segment Character Description CHOM 3060 L 200 G —C
Load Center Family CHOM CSA Listed
Spaces / Circuits 3060
Mains Type M Main circuit breaker
L Main lugs
Amps
Ground Bar G Factory included
Cover
C Combination flush / surface indoor cover
F Flush
RB Rainproof
S Surface
HomeLineCircuit Breakers
Number Segment Character Description CHOM 115
Brand CHOM Full Size
CHOMT Tandem/Quad
Number of Poles
Amps
Device Name
AFI Arc fault circuit interruption
BB High amp branch breaker
CAFI Combination arc fault circuit interruption
EPD Equipment protection device, 30mA
GFI Ground fault circuit interruption, 5mA
HM High magnetic trip
DF Dual function
DE1-22
DE1 LOAD CENTRES
08/16
Canadian HomeLine®Circuit Breakers and Loadcentres
Circuit Breakers and Accessories
Standard and Main Circuit Breakers
Standard Loadcentre Breakers
Notes:
1. AllCHOM1&2pole CSA listed as HACR type.
2. CHOM115 & 120 SWD rated.
3. CHOM2P150-2P200 require 4 spaces, use only in single phase loadcentres rated 150A or greater.
4. CHOM 1pole circuit breakers require one space. CHOM 2pole circuit breakers require two spaces.
5. High magnetic trip circuit breakers are recommended for applications where high initial inrush current may occur.
HomeLine Main Circuit Breakers
Type Amp
Rating
1 Pole Cat.
No.Lug Range 2 Pole Cat.No.Lug Range
CHOM 1,2&4
15 CHOM115
#14-#8
CHOM215
#14-#8
20 CHOM120 CHOM220
25 CHOM125 CHOM225
30 CHOM130 CHOM230
35 — CHOM235
#8-#2
40 CHOM140
#8-#2
CHOM240
45 —
50 CHOM150 CHOM250
CHOM 5
high magnetic
15 CHOM115HM #14-#8
20 CHOM120HM
CHOM 1&3
60 —
CHOM260
70 — CHOM270
80 — CHOM280
#4-2/0
90 — CHOM290
100 — CHOM2100
125 —
CHOM2125
150 — CHOM2150BB
#4-300mcm175 — CHOM2175BB
200 — CHOM2200BB
Type Amp
Rating 2 Pole Cat No.kAIC Lug Range
QOM1
30 QOM30L 10
#12-2/0
40 QOM40L 10
50 QOM50VHL
22
60 QOM60VHL
70 QOM70VHL
80 QOM80VHL
100 QOM100VHL
125 QOM125VHL
QOM2
100 QOM2100VHL
#4-300mcm
125 QOM2125VHL
150 QOM2150VHL
175 QOM175VHL
200 QOM2200VHL
225 QOM2225VHL
QOM2
DE1-23
DE1 HOMELINE
08/16
Canadian HomeLineCircuit Breakers and Loadcentres
Circuit Breakers and Accessories
CHOMT Breakers, Combination Arc Fault Circuit Interrupters, Dual Function Circuit Breakers
Notes:
1. CSA certified for use as HACR type circuit breakers.
2. Cat# represents two 1P outer poles and one 2P inner circuit breaker with common trip.
3. CHOMT tandems require 1 space.
4. CHOMT quad tandems require 2 spaces.
HomeLine Combination Arc-Fault Interrupter (CAFI)
HomeLine Combination Arc-Fault Interrupter (CAFI) provides overload and short circuit protection, plus both series and parallel
type arc protection as required in 2015 CEC. Integrated with Time Saver diagnostics, HomeLine CAFI breaker improves circuit
troubleshooting at the touch of a button.
*Rated for 120/240V ~60 Hz, not for 208Y/120V
HomeLine Dual Function Circuit Breaker
HomeLine Dual Function (DF) breaker provides both combination arc-fault and ground-fault (5mA classA) protection in a single
compact device. Integrated with Plug-on Neutral and Time Saver Diagnostics features, HomeLine DF breaker offers maximum
circuit protection and installation flexibility.
CHOMT Tandem & Quad Tandem Circuit Breakers
Type Amp Rating CHOMT Tandem Cat.No.Lug Range
CHOMT
Tandem 1&3
15-15 CHOMT1515
15-30A
#14-#8
15-20 CHOMT1520
20-20 CHOMT2020
30-15 CHOMT3015
30-20 CHOMT3020
CHOMT
Quad
Tandem 1,2&4
1P 2P Quad CHOMT Tandem Cat.No.
(2)15A 15A CHOMT1515215 15-30A
#14-#8
(2)15A 20A CHOMT1515220
(2)15A 25A CHOMT1515225
(2)15A 30A CHOMT1515230
(2)15A 40A CHOMT1515240
(2)15A 50A CHOMT1515250
(2)20A 20A CHOMT2020220
(2)20A 25A CHOMT2020225
(2)20A 30A CHOMT2020230 40-50A
#6-12 Al #6-14 Cu
(2)20A 40A CHOMT2020240
(2)20A 50A CHOMT2020250
Circuit Breaker Type Ampere Rating
1P 120 Vac
10K AIR
1 Space Required
2P 120/240 Vac
10K AIR
2 Space Required
HomeLine Pigtail Neutral CAFI 15 CHOM115CAFI CHOM215CAFI*
20 CHOM120CAFI CHOM220CAFI*
HomeLine Plug-on Neutral CAFI 15 CHOM115PCAFI
20 CHOM120PCAFI
Circuit Breaker Type Ampere Rating
1P 120 Vac 10K AIR
1 Space Required
Catalog Number
HomeLine Dual Function Circuit Breaker with
Pigtail Neutral
15 CHOM115DF
20 CHOM120DF
HomeLine Plug-on Neutral Dual Function
Circuit Breaker
15 CHOM115PDF
20 CHOM120PDF
DE1-24
Canadian HomeLineCircuit Breakers and Loadcentres
Circuit Breakers and Accessories
DE1 LOAD CENTRES
08/16
Note:Canadian HomeLine and QO loadcentre accessories may
Canadian HomeLine Breaker Accessories
Description Cat.No.
Handle attachments
Handle tie, converts any 2 adjacent 1P HOM circuit breakers to independent trip 2P HOM1HT
Handle tie, converts any adjacent 1P side by side HOMT CB's to independent 2P HOMTHT
Handle lock, ON or OFF, nonpadlocking HomeLine 1p 15-50A CB QO1LO
Handle blocking device, attaches to a HOM 2P CB for holding the handle in the OFF position HOM2HBD
Handle lock, ON or OFF, padlocking HomeLine 1p 15-50A CB HOM1PA
2 pole standard HomeLine handle lock ON or OFF, Padlocking
- Handle padlock attachment, for padlocking 2P 15-70A HOM2PALA
- Handle padlock attachment, for padlocking 2P 80-125A HOM2PAHA
- Handle padlock attachment, for padlocking 2P 150-200A HOM2PAVHA
Handle Padlock Attachment, for padlocking 1P CAFI,DF, GFI, and EPD CHOM breakers in ON or OFF position HOMELEC1PA
Handle Padlock Attachment, for padlocking 2P CAFI, GFI, and EPDC CHOM breakers in ON or OFF position HOMELEC2PALA
Handle padlock attachment, for padlocking centre poles of HOM quad breakers in the OFF position HOMQPA
Handle lock, OFF for QOM1 50-125A Main Circuit Breaker QOM1PA
Handle lock, OFF for QOM2 100-225A Main Circuit Breaker QOM2PA
Sub-feed Lugs
125A 2P plug-on - 2 spaces required HOML2125
225A 2P plug-on - 4 spaces required HOML2225
Ground Fault Circuit Interrupt-
ers, Arc Fault Circuit Interrupt-
ers
Notes:
1. GFI breakers maximum 250 feet (one way) feeder length
2. Use solid conductor only when #14 wire is used
Ground Fault Devices (GFI)
Spa Pack
A complete kit consisting of a Type 3R enclosure, factory installed 2P50A
GFCI circuit breaker.
HomeLine GFI with 5 mA Sensitivity (Class A)
Amp
Rating 1 Pole Cat.No.2 Pole Cat.No.
15 CHOM115GFI CHOM215GFI
20 CHOM120GFI CHOM220GFI
30 CHOM230GFI
40 CHOM240GFI
50 CHOM250GFI
HomeLine EPD with 30 mA Sensitivity
Type 1 Pole Cat.No.2 Pole Cat.No.
15 CHOM115EPD CHOM215EPD
20 CHOM120EPD CHOM220EPD
30 CHOM230EPD
40 CHOM240EPD
50 CHOM250EPD
Spa Pack
Amp Rating Poles Cat.No.
50 2 CHOME250SPA
CHOM115GFI CHOM230GFI CHOM115CAFICHOM215CAFI
CHOM115PCAFI
DE1-25
Canadian HomeLineCircuit Breakers and Loadcentres
Type 1 Main Lug and Main Circuit Breaker Loadcentres
DE1-25
DE1 LOAD CENTRES
08/16
kDoes not include a door. Order kit # CHOMDK602.
-Main Breaker loadcentres are approved for service entrance use. The main breaker compartment can be sealed and the main breaker can be locked.
-All type 1 loacentres are approved for vertical, horizontal, or inverted mounting.
-Canadian HomeLine loadcentres 8/16-space and above (double-row construction) come with Plug-on Neutral capability as standard.
Single-Phase, Three-Wire, 120/240 Vac Main Lugs – Indoor
Mains
Rating
in
Amps
Loadcentre
Catalogue Number
Maximum Number
of Circuits Loadcentre
Cover
Catalogue
Number
Service
Entrance
Approved
Maximum
Short
Circuit
Rating
Main
WireSize
AWG/kcmil
Al/Cu
Enclosure
No.
(Pages
34-35)
Top or
Bottom
Mains
Position
Standard 1" Tandem or
Quad
Factory-Installed Main Lugs
70 CHOM24L70F/S 2 4 Included N 10,000 A #12–3
#14–4 2 Top
100 CHOM612L100F/S 6 12 Included N 10,000 A #8–1 4 Top
125 CHOM48L125GC 4 8 Included N 10,000 A #4–2/0 21 Top
Factory-Installed Main Lugs
125
CHOM816L125GC 8 16 Included N 10,000 A #6–2/0 6 Both
CHOM1224L125GC 12 24 Included N 10,000 A #6–2/0 6 Both
CHOM1632L125GC 16 32 Included N 10,000 A #6–2/0 8 Both
CHOM2448L125GC 24 48 Included N 10,000 A #6–2/0 8 Both
CHOM3060L125GC 30 60 Included N 10,000 A #6-2/0 10 Both
Factory-Installed Main Lugs
225 CHOM3060L225GC 30 60 Included N 10,000 A #6–250 10 Both
CHOM4284L225GC 42 84 Included N 10,000 A #6–250 12 Both
Single-Phase, Three-Wire, 120/240 Vac Main Circuit Breaker – Indoor
Mains
Rating
in
Amps
Loadcentre
Catalogue Number
Maximum Number
of Circuits Loadcentre
Cover
Catalogue
Number
Service
Entrance
Approved
Maximum
Short
Circuit
Rating
Main
WireSize
AWG/kcmil
Al/Cu
Enclosure
No.
(Pages
34-35)
Top or
Bottom
Mains
Position
Standard 1" Tandem or
Quad
Factory-Installed Main Circuit Breaker
30 CHOM1224M30GC 12 24 Included Y 10,000 A #6-2/0 6 Both
50 CHOM1224M50GC 12 24 Included Y 22,000 A #6-2/0 6 Both
60 CHOM1224M60GC 12 24 Included Y 22,000 A #6-2/0 6 Both
CHOM1632M60GC 16 32 Included Y 22,000 A #6-2/0 7 Both
70 CHOM1224M70GC 12 24 Included Y 22,000 A #6-2/0 6 Both
CHOM1632M70GC 16 32 Included Y 22,000 A #6-2/0 7 Both
100
CHOM1224M100GC 12 24 Included Y 22,000 A #6-2/0 6 Both
CHOM1632M100GC 16 32 Included Y 22,000 A #6-2/0 7 Both
CHOM2448M100GC 24 48 Included Y 22,000 A #6-2/0 8 Both
CHOM3060M100GC 30 60 Included Y 22,000 A #6-2/0 10 Both
125
CHOM1224M125GC 12 24 Included Y 22,000 A #6-2/0 6 Both
CHOM1632M125GC 16 32 Included Y 22,000 A #6-2/0 8 Both
CHOM2448M125GC 24 48 Included Y 22,000 A #6-2/0 8 Both
CHOM3060M125GC 30 60 Included Y 22,000 A #6-2/0 10 Both
Factory-Installed Main Circuit Breaker
100
CHOM3060M2100GC 30 60 Included Y 22,000 A #4–250 10 Both
CHOM4284M2100GC 42 84 Included Y 22,000 A #4–250 12 Both
CHOM60120M2100GC 60 120 Included kY 22,000 A #4–250 24 Both
150
CHOM2040M150GC 20 40 Included Y 22,000 A #4–250 9 Both
CHOM3060M150GC 30 60 Included Y 22,000 A #4–250 10 Both
CHOM60120M150GC 60 120 Included kY 22,000 A #4–250 24 Both
200
CHOM2040M200GC 20 40 Included Y 22,000 A #4–250 9 Both
CHOM3060M200GC 30 60 Included Y 22,000 A #4–250 10 Both
CHOM4284M200GC 42 84 Included Y 22,000 A #4–250 12 Both
CHOM60120M200GC 60 120 Included kY 22,000 A #4–250 24 Both
Canadian HomeLineCircuit Breakers and Loadcentres
Type 3R Main Lug and Main Circuit Breaker Loadcentres
DE1 LOAD CENTRES
DE1-26
08/16
Single-Phase, Three-Wire, 120/240 Vac Main Lugs – Rainproof
Mains
Rating
in Amps
Loadcentre
Catalogue
Number
Maximum Number
of Circuits
Loadcentre
Cover
Catalogue
Number
Service
Entrance
Approved
Maximum
Short
Circuit
Rating
Main
WireSize
AWG/kcmil
Al/Cu
Enclosure
No.
(Pages
34-35)
Top or
Bottom
Mains
Position
Standard 1" Tandem or
Quad
Factory-Installed Main Lugs
70 CHOM24L70RB 2 4 Included N 10,000 A #12–3 Al
#14–4 Cu 1R Top
100 CHOM612L100RB 6 12 Included N 10,000 A #8–1 2R Top
125 CHOM48L125GRB 4 8 Included N 10,000 A #12–2/0 Al
#14–2/0 Cu 15R Top
Factory-Installed Main Lugs
125 CHOM816L125GRB 8 16 Included N 10,000 A #6–2/0 3R Top
CHOM1224L125GRB 12 24 Included N 10,000 A #6–2/0 3R Top
Single-Phase Three Wire 120/240 Vac Main Breaker – Rainproof
Factory-Installed Main Circuit Breaker
100 CHOM816M100GRB 8 16 Included Y 22,000 A #6-1 3R Top
CHOM1224M100GRB 12 24 Included Y 22,000 A #6-2/0 3R Top
Factory-Installed Main Circuit Breaker
200 CHOM2040M200GRB 20 40 Included Y 22,000 A #4–250 6R Top
-Canadian HomeLine loadcentres 8/16-space and above (double-row construction) come with Plug-on Neutral capability as standard.
DE1-27
Canadian HomeLineCircuit Breakers and Loadcentres
Loadcentres
DE1 HOMELINE
08/16
HomeLine Fusible Loadcentre Inserts (HFLCI)
Fusible Loadcentre Inserts
HomeLine Fusible Loadcentre Inserts (HFLCI) offer the safety and reliability of a modern circuit breaker loadcentre system
featuring HomeLine circuit breakers.
Easily replaces outdated fusible loadcentres.
Eliminates drywall removal and repair.
Eliminates painting new drywall.
No holes to drill.
No new ground required.
No branch conductors or conduit to remove.
Using the HomeLine FLCI substantially reduces installation time, as much as 80%, allowing for the economical replacement of
old fusible loadcentres.
Step #1
Identify Box Dimensions and
Catalogue Number
Step #2
Remove Old Fusible
Interior
Step #3
Install New HFLCI
Step #4
Complete Installation
DE1-28
Canadian HomeLineCircuit Breakers and Loadcentres
Loadcentres
DE1 LOAD CENTRES
08/16
HomeLine Fusible Loadcentre Inserts (HFLCI)
READ THIS FIRST!
To select the proper HFLCI, follow these three steps:
Step 1:Find your fusible loadcentre catalogue number using columns 1 and 2.
Step 2:Confirm that the original fusible loadcentre box dimensions match those in columns 5, 6, and 7.
Step 3:Use column 3 to identify the HomeLine Fusible Loadcentre Insert (HFLCI) catalogue number.
CAUTION:Do not proceed with an installation unless both the existing catalogue number and box dimensions match.
Note:Not suitable for use with Canadian HomeLine AFI, CAFI, DF or GFI devices.
1234567
Original
Manufacturer
Original Main
Lug Loadcentre
Catalogue
Number
HomeLine
Catalogue
Number**
Maximum Number
of Circuits
Box Dimensions
Height Width Depth
Standard 1" Tandem
or Quad Inches mm Inches mm Inches mm
Amalgamated Electric 4208 HFLCI12D 6 12 16.126 410 8.506 216 2.813 72
Amalgamated Electric 4212 HFLCI16D 8 16 19.506 496 8.506 216 2.813 72
Amalgamated Electric 4220 HFLCI20AD 10 20 24.256 616 8.506 216 2.813 72
Amalgamated Electric 4220 HFLCI24AD 12 24 24.256 616 8.506 216 2.813 72
Amalgamated Electric 4216 HFLCI20BD 10 20 23.126 587 8.506 216 2.813 72
Amalgamated Electric 4216 HFLCI24BD 12 24 23.126 587 8.506 216 2.813 72
Amalgamated Electric 4312 HFLCI20BD 10 20 23.126 587 8.506 216 2.813 72
Amalgamated Electric 4312 HFLCI24BD 12 24 23.126 587 8.506 216 2.813 72
CEB NHP10-634 HFLCIC16BD 8 16 20.126 511 7.876 200 3.063 78
CEB NHP10-636-3 HFLCIC20BD 10 20 24.126 613 10.126 257 3.063 78
CEB NHP10-636-3 HFLCIC20ED 10 20 27.876 708 10.251 261 3.063 78
CEB NHP10-636-3 HFLCIC24BD 12 24 24.126 613 10.126 257 3.063 78
CEB NHP12-60 HFLCIC12DD 6 12 20.126 511 7.876 200 3.063 78
CEB NHP12-633 HFLCIC20AD 10 20 23.126 587 7.876 200 3.063 78
CEB NHP12-633 HFLCIC24AD 12 24 23.126 587 7.876 200 3.063 78
CEB NHP4-632 HFLCIC12BD 6 12 16.256 413 7.876 200 3.063 78
CEB NHP4-632-1 HFLCIC16D 8 16 19.126 486 7.876 200 3.063 78
CEB NHP4-633-1 HFLCIC16D 8 16 19.126 486 7.876 200 3.063 78
CEB NHP6-60 HFLCIC12CD 6 12 13.876 353 7.876 200 3.063 78
CEB NHP6-633-1 HFLCIC16BD 8 16 20.126 511 7.876 200 3.063 78
CEB NHP6-636-4 HFLCIC16CD 8 16 24.126 613 7.876 200 3.063 78
CEB NHP8-60 HFLCIC12D 6 12 16.256 413 7.876 200 3.063 78
CEB NHP8-635-2 HFLCIC20AD 10 20 23.126 587 7.876 200 3.063 78
CEB NHP8-635-2 HFLCIC24AD 12 24 23.126 587 7.876 200 3.063 78
Taylor (Crouse Hinds) NHP0020 HFLCIT8AD 4 8 12.876 327 9.626 245 3.063 78
Taylor (Crouse Hinds) NHP6-30-60 HFLCIT16AD 8 16 21.126 537 7.506 191 3.063 78
Taylor (Crouse Hinds) NHP1231 HFLCIT20AD 10 20 24.626 626 9.626 245 3.063 78
Taylor (Crouse Hinds) NHP20-0821-6 HFLCIT20AD 10 20 24.626 626 9.626 245 3.063 78
** HomeLine FLCI's include distribution section interior, trim, door and painted architectural white.
Canadian HomeLineCircuit Breakers and Loadcentres
DE1 LOAD CENTRES
DE1-29
08/16
Accessories
Plug-in surge breaker
Ground bars
Neutral lugs
Filler plates
Type 3R rain hubs
Type 3R coupling trough
Door lock
Main lugs
Replacement covers
Replacement interiors
RB Hub
BC200 Enclosure Coupling
CHOM Surgebreaker®
Surge Arrester
2 spaces required.
PK15GTA
LK100AN
HOMFP
QOM1FP
QOM2FP
PK6FL
QOL125
QOL225
Canadian HomeLine™ Circuit Breakers and Loadcentres
HomeLine Loadcentre Accessories
DE1-30
08/16
DE1 LOAD CENTRES
*No door on cover.
Replacement Covers, 1 Phase, Type 1 Enclosures ONLY
Reference Loadcentre Catalogue
Number
Replacement
Cover
Catalogue
Number
CHOM24L70S *4055800801
CHOM24L70RB 4056314401
CHOM24L70F *4055800701
CHOM48L125GC 4055844801
CHOM48L125GRB 4056318650
CHOM612L100S *4055801702
CHOM612L100F *4055801801
CHOM612L100RB 4056318550
CHOM816M100GRB 4056319050
CHOM1224M100GRB 4056319050
CHOM2040M200GRB 4056319150
CHOM 8-16,12-24 ML-MB loadcentres CHOMC12UC
CHOM 16-32 60-100A MB loadcentres CHOMC21UC
CHOM 16-32 125A, 24-48 ML-MB loadcentres CHOMC24UC
CHOM 30-60 100-125A MB loadcentres CHOMC30U125C
CHOM 30-60 150-225A ML-MB loadcentres CHOMC30UC
CHOM 42-84 ML-MB loadcentres CHOMC42UC
CHOM 20-40 MB loadcentres CHOMC20UC
Door Lock Kits, 1 Phase, Type 1 Enclosures ONLY
Catalogue Number Description
PK6FL For use with type 1 Canadian
HomeLine Loadcentres.
Surge Protective Device
Description
Catalogue
Number
Surge arrester for 1PH3W system
150Vac maximum phase-to-ground CHOM2175SB
Interchangeable Hubs
Conduit Size Type B Hubs
Closing Plate BCAP
3/4" B075
1" B100
1 1/4" B125
1 1/2" B150
2" B200
2 1/2" B250
Coupling Trough
Catalogue Number Description
BC200 BC200 - enclosure coupling for RB devices
Filler Plates
Description Catalogue Number
Branch Breaker HOMFP
QOM1 Main Breaker QOM1FP
QOM2 Main Breaker QOM2FP
Optional Neutral Lugs
Wire Size Catalogue Number
#12-2 AL
#14-4 Cu LK70AN
#6-2/0 AL/Cu LK100AN
#14-2/0 AL/Cu LK125AN
#2-3/0 Al/Cu LK150AN
Main Lug Kits
Catalogue Number Description
QOL125 125A Kit
QOL225 225A Kit
B-150
DE1-31
Canadian HomeLineCircuit Breakers and Loadcentres
Technical Information
DE1 LOAD CENTRES
08/16
TECHNICAL INFORMATION
Grounding Bar Kits
All PK equipment grounding bar kits are supplied
with mounting screws, necessary installation
instructions and an Equipment Grounding
Terminalself-adhesive label.
Wire Range Table
n
screw
s
Section of Size 1 Groun
d
0.3125
[8]
D
Catalogue
Number
Total
Qty.
Terminals
Approximate
Overall
Length
Distance
Between
Mounting
Holes Mounting
Quantity Each Size
See “Wire Range
Table” below.
I II III IV V VI in [mm] in [mm]
PK0GTA2 2 ———— 2 1.75 [44] One
hole
One
hole Top
PK0GTA6 6 — — — 6 4.61 [117] 1.69 [43] Top
PK3GTA1 3 3 ————— 1.38 [35] One
hole
One
hole Top
PK4GTA 4 4 ————— 1.63 [41] One
hole
One
hole Top
PK5GTA 5 5 ————— 2.25 [57] 1.25 [32] Top
PK7GTA 7 7 ————— 2.88 [73] 1.25 [32]
Top
or
Side
PK9GTA1 9 9 ————— 3.25 [83] One
hole
One
hole Top
PK9GTA 9 9 ————— 3.78 [96] 3.13 [80] Top
PK12GTA 12 12 ————— 4.70 [119] 3.13 [80] Top
PK15GTA 15 15 ————— 5.63 [143] 3.13 [80] Top
PK15GTAL 16 15 1 ———— 8.13 [207] 3.13 [80] Top
PK15GTA6 121 15 — — 6 — — 5.88 [149] 2Top
PK18GTA 18 18 ————— 6.56 [167] 3.13 [80] Top
PK18GTAL 19 18 1 ———— 8.81 [224] 3.13 [80] Top
PK23GTA 23 23 ————— 8.11 [206] 3.13 [80] Top
PK23GTAL 24 23 1 ———— 9.44 [240] 3.13 [80] Top
PK27GTA 327
or
26
27
or
26
1 — — — 9.36 [238] 3.13 [80] Top
1Mounting screws 21594-14241(two required) and 21594-17121(two required).
23.13 in. (80 mm) on small terminals;5.25 in. (133 mm) on large terminals.
3PK27GTA includes one main grounding lug that mounts with two terminal screws and requires
three terminals for mounting.
Size Cu (AWG) Al (AWG)
I (1) #14–#4 or (2) #14 or #12 (1) #12–#4 or (2) #12 or #10
II (1) #1–4/0 (1) #1–4/0
III (1) #6–2/0 (1) #6–2/0
IV (1) #6–3/0 (1) #6–3/0
V (1) #14–1/0 (1) #14–1/0
VI (1) #10–2/0 (1) #6–2/0
Canadian HomeLine™ Circuit Breakers and Loadcentres
Wiring Diagrams
DE1 LOAD CENTRES
DE1-32
08/16
WIRING DIAGRAMS
CHOM24L70S/F
CHOM24L70RB
S
N
CHOM612L100S/F
CHOM612L100RB
S/N
CHOM816L125GC
CHOM816L125GRB
CHOM1224L125GC
S
N
S
N
S
N
S
N
S
N
CHOM1632L125GC
CHOM3060L225GC CHOM4284L225GC
CHOM2448L125GC
CHOM1224L125GRB
S
N
S
N
S
N
S
N
S
N
S
N
S
N
DE1-33
Canadian HomeLineCircuit Breakers and Loadcentres
Wiring Diagrams
DE1 LOAD CENTRES
08/16
1-Phase, 3-Wire Main Circuit Breakers
S
N
CHOM816M100RB
S
N
MAIN
S
N
CHOM1224M100GC
S
N
MAIN
S
N
CHOM1632M100GC
CHOM1632M125GC
S
N
MAIN
CHOM2040M150GC
S
N
MAIN
S
N
CHOM2448M100GC
CHOM2448M125GC
CHOM3060M100GC
CHOM3060M125GC
MAIN
S
N
CHOM60120M200GC
S
N
CHOM4284M200GC
CHOM4284M2100GC
CHOM1224M125GC
CHOM1224M100GR
CHOM2040M200GC
CHOM2040M200GRB
MAIN
MAIN
CHOM3060M150GC
CHOM3060M200GC
CHOM3060M2100GC
MAIN
S
N
S
N
S
N
S
N
S
N
S
N
Canadian HomeLine™ Circuit Breakers and Loadcentres
Wiring Diagrams
DE1 LOAD CENTRES
DE1-34
08/16
Indoor Dimensions
Box
No.
W H D
in.mm in.mm in.mm
2 4.81 122 9.30 236 3.19 81
4 8.88 226 12.57 319 3.80 97
6 14.25 362 17.92 455 3.75 95
7 14.25 362 20.92 531 3.75 95
8 14.25 362 26.04 661 3.75 95
9 14.25 362 29.86 758 3.75 95
10 14.25 362 33.78 858 3.75 95
12 14.25 362 39.37 1000 3.75 95
21 8.88 226 14.80 376 3.80 97
24*14.25 362 48.50 1232 3.75 95
Knockouts
Symbol AB C D E F G H I
Conduit
Size
0.50 in.
13 mm
0.75 in.
19 mm
1.00 in.
25 mm
1.25 in.
32 mm
1.50 in.
38 mm
2.00 in.
51 mm
2.50 in.
64 mm
3.00 in.
76 mm
3.50 in.
89 mm
*Note:Box 24 knockout drawing to follow.
Box 10
A
A
A, B,
CA, B, C
A, B, C, D
Box 2
A,
B
Box 4
A
B, C,
D, E B, C, D, E
B, C, D, E
B, C,
D, E B, C, D, E
B, C, D, E
A
C, D, E, F
A
A, B, C, D
A, B
B, C, D, E
A, B
A
B, C, D, E
C, D, E,
F,G
Box 6
A, B, C, D
AA, B
B, C, D,E
B, C, D, E
C, D, E, F
Box 8
C, D, E,
F,G
C, D, E, F
D, E,
F, G
D, E, F, G
A
A, B
A, B, C, D
B, C, D, E
C, D, E, F
AA, B
D, E,
F, G
Box 9
B, C
B, C, D, E
C, D, E,
F,G
B, C
A
A, B
D, E,
F, G C, D, E, F
A, B, C, D,
D, E, F, G
C, D, E, F
B, C, D, E
C, D, E,
F,G AA, B
B, C, D, E
D, E, F, G
D, E, F, G
C, D, E, F
A, B, C, D
B, C, D, E
B, C, D, E
D, E, F, G
C, D, E,
F, G
C, D, E, F
A, B
A
A
A, B
B, C
B, C, D, E
Box 12
A
B, C, D, E
B, C, D, E
A, B AB, C, D, E
B, C, D, E
B, C, D, E
B, C, D, E
Box 21
IND
OO
R DIMEN
S
I
O
N
S
AND KN
OC
K
O
UT
S
C, D, E, F
A
A, B, C, D
A, B
B, C, D, E
A, B
B, C, D, E
C, D, E,
F,G
Box 7
A
Indoor Dimensions and Knockouts
DE1-35
Canadian HomeLineCircuit Breakers and Loadcentres
Outdoor Dimensions and Knockouts
DE1 LOAD CENTRES
08/16
OUTDOOR DIMENSIONS AND KNOCKOUTS
Outdoor Dimensions
Box No.
W H D
in.mm in.mm in.mm
1R1
1CHOME250SPA top endwall has no hub opening.
4.88 124 9.38 238 4.00 102
2R 8.88 226 12.65 321 4.27 108
3R 14.75 375 18.92 481 4.52 115
6R 14.75 375 29.86 758 4.52 115
15R 8.88 226 14.80 376 4.27 108
Knockouts
Symbol ABCDEFGH
Conduit
Size
0.50 in.
13 mm
0.75 in.
19 mm
1.00 in.
25 mm
1.25 in.
32 mm
1.50 in.
38 mm
2.00 in.
51 mm
2.50 in.
64 mm
3.00 in.
76 mm
Box 3R
Box 1R
2.5 in. (64 mm)
Hub Max.
A, B, C, D A
A, B
Box 2R
2.5 in. (64 mm)
Hub Max.
B, C, D, E A
B, C, D, E A, B
B, C,
D, E
2.5 in. (64 mm)
Hub Max.
C,D,EF,G
C, D,
E, F AA,
B
C, D,
E, F,
G
A, B, C
C, D, E, F
C, D, E, F, G
C, D,
E, F AA, B C, D,
E, F, G
A, B, C
C, D, E, F
Box 6R
2.5 in. (64 mm)
Hub Max.
Box 15R
2.5 in. (64 mm)
Hub Max.
B, C, D, E A
B, C, D, EA, B
B, C, D, E
E.&O.E.
DE1-36
Intentionally left blank
DE1 LOAD CENTRES
08/16
DE1-37
Stab-lok Circuit Breakers
General Information
DE1 LOAD CENTRES
08/16
Features and Benefits
Breaker Features:
Type NC with Robertson/slot screws
Type NC with colour coded handles
Thermal magnetic trip protection
Exclusive line side stab connection
Trip free operation
Calibrated at 40° C
Availability of a wide range of GFCIs
Arc resistant case
Stab-lok Breaker Rating Table
Type Poles Amp
Rating
Maximum
Voltage
Interrupting
Capacity
NC 1 15-50 120 10,000 A
2 15-50 120/240 10,000 A
NA
1 15-50 120 10,000 A
2 15-150 120/240 10,000 A
3 15-100 240 10,000 A
1C 2 30-40 120/240 10,000 A
50-125 22,000 A
2C 2 100-200 120/240 22,000 A
NA15 NA215
NA3P20 NA2P100
NA The Original Stab-lok Breaker - 1” Wide per pole
NC The Compact Stab-lok Breaker -
1/2” Wide per pole
NC015, NC0215, NC0230
DE1-38
Stab-lok Circuit Breakers
Circuit Breakers and Accessories
DE1 LOAD CENTRES
08/16
Standard and Main Circuit Breakers
Standard Loadcentre Breakers
Notes:
1. NA2P150 rated 150A when used with copper conductor only
2. Switching duty approved breakers. Breakers are marked SWD
3. 2-pole and 3-pole breakers greater than 70A take 4 and 6 NA breaker
positions respectively
4. Use solid conductor only when #14 wire is used
5. *
Stab-lok Main Circuit Breakers
*NC015/NC0215 Breaker Handle Colour - Blue
NC020/NC0220 Breaker Handle Colour - Red
NC030/NC0230 Breaker Handle Colour - Green
NC040/NC0240 Breaker Handle Colour - Grey
Type Amp
Rating
1 Pole Cat.
No.
List
Price Lug Range 2 Pole Cat.
No.
List
Price Lug Range 3 Pole Cat.
No.
List
Price Lug Range
NC
15 NC015
#14-#6
NC0215
#14-#6
——
20 NC020 NC0220
25 NC025 NC0225
30 NC030 NC0230
40 NC040 NC0240
50 NC050 #14 - #4 NC0250 #14 - #4
NA
15 NA15(2)
#14-#2
NA215
#14-#2
NA3P15
#14 - 1/0
20 NA20(2) NA220 NA3P20
25 NA25 NA225
30 NA30 NA230 NA3P30
35 NA35
40 NA40 NA240 NA3P40
50 NA50 NA250 NA3P50
60 — —
NA260 NA3P60
70 — — NA270 NA3P70
90 — — NA2P90
#4 - 2/0
NA3P90
100 — NA2P100 NA3P100
125 — NA2P125
150 — NA2P1501——
Type Amp
Rating
2 Pole Cat
No.List Price Lug Range 3 Pole Cat
No.List Price Lug
Range
NA 30-100 Use Breaker Table Above
1C
30 1C30
#4-2/0
——
40 1C40 — —
50 1C50 — —
60 1C60 — —
70 1C70 — —
90 1C90 — —
100 1C100
125 1C125
2C
100 2C100
#4-250MCM
——
125 2C125
150 2C150
175 2C175
200 2C200
2C200
DE1-39
Stab-lok Circuit Breakers
DE1 LOAD CENTRES
08/16
Stab-lok Breaker Accessories
Note:Standard Packaging Size for all breaker accessories is 10
1. Suitable for ribbed handled NC breakers.
2. Suitable for square handled NC breakers.
3. Suitable for ribbed handled NC1+2pole breakers.
Stab-lok Breaker Accessories
Breaker Type Poles Amp Rating
Handle Lock Off Non-
Padlocking
Handle Lock Off
Padlocking Handle Tie
Cat.No.List Price Cat.No.List Price Cat.No.List Price
NC
1 15-50 NCLOK(3) / 1LOK(2) ——
NCTIE(1) / HTNC(2)
2 15-50
CLOK
(Not suitable for
ribbed handles)
——
NA
1 15 - 50 1LOK 1LOB
HTNA
(Not to be used for 2
pole applications)
2 15-70
2LOK
(2+3 pole
modular)
——
2 90 - 150 CLOK
3 Non - Modular 3100LOK
3 Modular — 2LOK
DE1-40
Stab-lok Circuit Breakers
DE1 LOAD CENTRES
08/16
Ground Fault Circuit Breakers and Spa Pack
Circuit Breakers
Notes:
1. Submersible pump installations require ground fault protection to the
maximum sensitivity level of 10mA. These breakers are designed to
meet the Canadian Electrical Code under rule CEC 26-956
2. GFI breakers maximum 250 feet (one way) feeder length
3. Use solid conductor only when #14 wire is used
4. GFI 15 Amp Handles - Blue, GFI 20 Amp Handles - Red,
GFI 30 Amp Handles - Green, GFI 40 Amp Handles - Grey
Stab-lok GFI with 5 mA Sensitivity (Class A)
Type Amp
Rating
1 Pole
Cat.No.
List
Price
2 Pole
Cat.No.
List
Price
NA
15 NAGF15 NAGF215
20 NAGF20 NAGF220
30 NAGF30 NAGF230
40 NAGF40 NAGF240
Stab-lok GFI with 33 mA Sensitivity
Type Amp
Rating
1 Pole Cat.
No.
List
Price
2 Pole Cat.
No.
List
Price
NA
15 NAGF1533 NAGF21533
20 NAGF2033 NAGF22033
30 NAGF3033 NAGF23033
40 NAGF4033 NAGF24033
Stab-lok GFI with 10mA Sensitivity
Type Amp Rating 2 Pole Cat.No.List Price
NA
15 NAGF21510
20 NAGF22010
30 NAGF23010
40 NAGF24010
NAGF215NAGF15
DE1-41
Stab-lok Circuit Breakers
DE1 LOAD CENTRES
08/16
Arc-Fault Circuit Interrupters and Stab-lok Generator Panel - Replacement Breakers
As per the Canadian Electrical Code (CEC), AFCIs will be required for ALL bedroom receptacle circuits beginning January 2002. The CEC does not
mandate existing homes be upgraded with AFCIs. However, if a new bedroom is added, the AFCI will be required. Reduce the risk of fire with the
installation of Federal Pioneer arc-fault circuit interrupters.
Arc faults are any abnormal flow of electricity that create an arc, spark or
flash which is hot and capable of igniting flammable materials, thereby
increasing the potential for a residential fire.
Arcing can occur and may lead to fires in these common conditions:
pierced insulation on electrical construction wire
frayed appliance extension cords
loose electrical connections
overheated electrical cords and wires
The Federal Pioneer AFCI utilizes state-of-the-art digital microprocessor
technology that has been coupled with a Stab-lok circuit breaker. These
devices will disconnect power to the circuit during any of these conditions:
short circuit
• overload
arc faults - parallel, line-to-neutral or line-to-ground, or in series on a
damaged wire
Federal Pioneer AFCI can be installed in any new or existing Stab-lok
load centre.
*NA15AFI Breaker Handle Colour - Blue
NA20AFI Breaker Handle Colour - Red
Stab-lok - AFCI Stab-lok Arc Fault Circuit Interrupters (10,000 AIR)
Ampere Rating Poles
120Vac Catalogue Number
15 1 NA15AFI
20 1 NA20AFI
Stab-lok Generator Panel - Replacement Breakers
Catalogue
Number
Amp
Rating Main Breaker Type List Price
NA3P30GEN 30 NA3P30 Amp Modular Breaker-Transfer Disconnect
NA3P60GEN 60 NA3P60 Amp Modular Breaker-Transfer Disconnect
NA3P70GEN 70 NA3P70 Amp Modular Breaker-Transfer Disconnect
DE1-42
Stab-lok Circuit Breakers
DE1 LOAD CENTRES
08/16
Recreation Vehicle Park Power Centre - Receptacle Kits
Receptacle Kits
Description Cat.No.
Receptacle Kits for RH102-4CHTS
One 15A 125V duplex with break-off tabs for separate feed. (Eagle #4270B) K1
One 30A 125V (Eagle #1263) K3
Side blanking plate for RH102-4CHTS units. RH1024CHTSBRC
Receptacle Kits for RH104-8CHTS
One 15A 125V duplex with break-off tabs for separate feed. (Eagle #4270B) RM15
Two 15A 125V duplex with break-off tabs for (Eagle #4270B) RM1515
15A receptacle module kit 1-1 GFI
15A (Hubbell GFR5252) RM15GFI
15A receptacle module kit 2-1 GFI
15A (Hubbell GFR5252) RM1515GFI
20A receptacle module kit 2-1 GFI
20A (Leviton 8899) RM2020GFIS
One 30A 125V (Eagle #1263) RM30
One 50A 125/250V (Eagle #58) RM50
One 30A 125V and one 15A 125V duplex with break-off tabs for separate
feed (Eagle #1263 & #4270B) RM1530
One 30A 125V and one 15A GFI receptacle (Hubbell GFR5252) RM15GFI30
One 125V twist lock 20A (Hubbell #23CM10) 30A (Hubbell #26CM10) RM20TL
RM30TL
Side blanking plate for RH104-8CHTS using non-twist lock receptacle kits.
Side blanking plate for RH104-8CHTS using twist lock receptacle kits.
RM00
RMBLTL
Stab-lok Loadcentres and Circuit Breakers
Accessories
DE1 LOAD CENTRES
DE1-43
04/16
Stab-lok Loadcentre Accessories
Note:For use with W98 Series Stab-lok loadcentres.
Note:For use with W98 Series Stab-lok loadcentre interior. Single phase
only.
Door Kits, 1 Phase, Type 1 Enclosures ONLY
Reference Loadcentre
Catalogue Number
Door Kit
Catalogue
Number
List Price Std.Package
Size
108-16-125 DK1W98
3
112-24-125 DK2W98
116-32-125 DK3W98
120-40-125 DK4W98
124-48-125 DK5W98
132-64-225 DK8W98
142-84-225 DK9W98
BE108-16-1CXXX DK1BEW98
BE112-24-1CXXX DK2BEW98
BE116-32-1CXXX DK3BEW98
BE120-40-1CXXX DK4BEW98
BE124-48-1CXXX DK5BEW98
BE132-64-1CXXX DK6BEW98
BE120-40-2CXXX DK7BEW98
BE124-48-2CXXX DK7BEW98
BE132-64-2CXXX DK8BEW98
BE142-84-2CXXX DK9BEW98
Door Lock Kits, 1 Phase, Type 1 Enclosures ONLY
Catalogue Number List Price Description
PK6FL For use with 125 and 225A W98
Series Stab-lok loadcentres.
Main Lug Kits
Max.Bus Rating (A) Main Lug Kit Catalogue
Number List Price
125A QOL125
225A QOL225
Filler Plates
Catalogue
Number Description List
Price
PF1
Filler plate for NA or NC breakers. For use in
present design of Stab-lok enclosures, except
400 A - see BFAB. Will also fit previous design
using 1/2metal KOs PF1 consists of 1 strip of 4
1/2plastic fillers suitable for 4 NC poles or 2 NA
poles.
Minimum order quantity 25
BFAB
Filler plate for 1 NA breaker. For use in present
400 A enclosure design and previous enclosure
designs using aluminum center strip.
Minimum order quantity:50
DK3W98
PK6FL
BFAB
PF1
DE1-44
Stab-lok Circuit Breakers
DE1 LOAD CENTRES
08/16
Stab-lok Loadcentre Accessories
*For use with 125A W98 Series Stab-lok Loadcentres.
** Sub-feed lugs for 225A W98 Series may be ordered as a factory installed option.
Note:Suitable for Cu/Al conductors.
Sub-Feed Kits, MLO Panels Only
Enclosure
Cat.
No.
Ordering
Catalogue
Number
List
Price
Amp
Rating
(A)
Lug Range
10816125
SFL125W98*125 A #6-300MCM
11224125
11632125
12040125
12448125
31224 S/F SFL100 100 A #14-1/0
31836 S/F
SFL225 225 A #6-300MCM33060 S/F
34284225 S/F
Ground Lug Kits
No.of Ccts
Ordering
Catalogue
Number
List
Price Lug Range
3 L79A253
#14-#4
6 GLK6
10 GLK10
12 GLK12
Neutral Lug Kits
Amp Rating
Ordering
Catalogue
Number
List Price Lug Size
150 NLK150W98 #6 - 2/0
SFL100 GLK12
Drip Proof Hoods EEMAC 2
Enclosure Cat.
No.
Ordering
Catalogue
Number
Std.Package
Size List Price
1022S R2 4
1024S
1048S R4 2
31224S
SDH 1
31836S
33060S
34284225S
Touch Up Paint
Description Ordering
Catalogue Number List Price
Architectural White ARCWHITE

Navigation menu