Loadcentres and Circuit Breakers
Square D QO® Loadcentres and Circuit Breakers Selection Guide
Page

•

Product Illustrations/Features

3-4

•

QO® Standard Breakers and Tandem Circuit Breakers.

•
•

QO® Special Breakers (QO-CAFI, QO-DF, QO-GFI, QO-EPD, QO-HID, QO-AFI, QO-K, and
QO-HM)
Circuit Breaker Factory Installed Accessories

•

Circuit Breaker Wire Sizes

7

•

QO® Main Lugs Loadcentres - Type 1 Indoor

8

QO® Breakers

QO®

5
6
7

Loadcentres
•

®

QO 'Stand Alone' Generator Panels
®

8

•

QO Combination SE 'all-in-one' Generator Panels

8
9

•

QO® Main

•

QO® Main Lugs/Main Breaker Loadcentres - Type 3R Weatherproof

•

QO® Plug-on Neutral Loadcentres

10
11

•

QO® Recreational Vehicle Park (ServicePak® Panels) and Mobile Home and Trailer Loadcentres

12

•

QO® Loadcentre and Circuit Breaker Accessories

13

•

QO®

14

•

Secondary Surge Suppressors and Surge Arresters

15

•

Enclosure Dimensions

16

Breaker Loadcentres - Type 1 Indoor

Accessories
single phase loadcentre field installed neutral extension kits

Dimensional Information

HomeLine™ Loadcentres and Circuit Breakers Selection Guide
General Information
•

Product Illustrations / Features

•

Nomenclature Charts

17-20
21

•

Standard and Main Circuit Breakers

22

•

Tandem and Quad Circuit Breakersr

23

HomeLine Breakers

•

CAFI and DF

23

•

GFI, AFCI

24

•

Breaker Accessories

24

•

Indoor Single Phase Main Lug & Main Circuit Breaker Loadcentres

25

•

Outdoor Single Phase Main Lug & Main Circuit Breaker Loadcentres

26

•

HomeLine Fusible Loadcentre Inserts

27

•

HomeLine Loadcentre Accessories

29

•

Wiring Diagrams

•

Indoor Loadcentre Dimensions and Knockouts

34

•

Outdoor Loadcentre Dimensions and Knockouts

35

HomeLine Loadcentres

Technical Information

08/16

32-33

DE1-1

LOAD CENTRES

Description

General Information

DE1

Contents

Loadcentres and Circuit Breakers

General Information
•

Stab-lok®

DE1

LOAD CENTRES

Federal Pioneer Stab-lok® Circuit Breakers Selection Guide

Features and Benefits

37

Replacement Circuit Breakers and Accessories
•

Standard and Main Circuit Breakers

38

•

Stab-lok Breaker Accessories

39

•

Ground Fault Circuit Breakers and Spa Buddy

40

•

Arc-Fault Circuit Interrupters and Stab-lok Generator Panel - Replacement Breakers

41

Stab-lok® Replacement RV Panel Receptacle Kits
•

Stab-lok®

42

Loadcentre Replacement Accessories
•

DE1-2

Recreational Vehicle Park Power Centre - Receptacle Kits

Stab-lok Loadcentre Replacement Accessories

43-44

08/16

QO® Loadcentres and Circuit Breakers
General Information

Application:

Standards:

•

DE1-5 to DE1-14

•
•

Residential, commercial, and
industrial
30 through 225 Amperes

•

CSA Certified under File

DE1

Pages:

LOAD CENTRES

QO® Loadcentres

#LL-89066

Enclosures:

Features:

•

Type 1 and 3R

•

One piece, plated, shielded
copper bus (S-Series)
Split branch neutral with 3-1/0
“built in” branch neutral lugs
Combination Slot/Robertson
neutral, ground and trim screws
Additional ground bar provisions

•
•
•

Accessories:

08/16

•

Trims have automatic flush
adjustment

•

Secondary Surge Arresters

•

Sub-Feed Lugs

•
•

Filler Plates (for branch and main
breakers)
Door Lock Kits

•

Neutral Lugs

•

QO single phase neutral
extension kits

DE1-3

QO® Loadcentres and Circuit Breakers
General Information
QO® Circuit Breaker

DE1

LOAD CENTRES

Branches:

Features:

•

QO-CAFI - Combination Arc Fault Circuit Interrupter

•

QO-DF - Dual Function - CAFI+GFI (5mA)

•

QO - Plug-On Circuit Breakers

•

QO-GFI - Ground Fault Indication

•

QOT - Tandem Breakers

•

QO-EPD - Equipment Ground Fault Protection

•

QO-HID - High Intensity Discharge Lighting Systems

•

QO-K - Key Operated Breakers

•

QO-AFI - ARC Fault Circuit Interrupters

•

QO-HM - High Magnetics

•

QWIK-OPEN® Circuit Breakers

•
•

VISI-TRIP® Indicator
Tandem Circuit Breakers feature two 1-Pole breakers
in the space of a 1-Pole QO breaker

•

QO2175SB SURGEBREAKER® Secondary Surge
suppressor
Shunt Trips, Auxiliary Switches, and Alarm Switches
are all available factory installed

•

For additional information,
– QO & QOB Miniature Circuit Breakers Catalogue 0730CT9801R1/08.
– QO-EPD Catalogue 0950CT9601
– Square D Series Ratings Guide Catalogue D0110AB9801EP R0
– Secondary Surge Arresters Catalogue 6671CT9701R9/06

DE1-4

08/16

QO® Loadcentres and Circuit Breakers

Plug-On Circuit Breakers - Amperes Interrupting Rating (AIR) in Amperes RMS Symmetrical
Ampere
One Pole - 120/240Vac
Two Pole - 120/240Vac
Three Pole - 240Vac
Rating '
Common Trip
Common Trip
10,000 AIR
QO110
QO115◆▲
QO115HM◆▲‡
QO120◆▲
QO120HM◆▲‡
QO125
QO130◆
QO135◆
QO140◆
QO145◆
QO150◆
QO160◆
QO170◆

–
–
–
–
–
–
–
–

QO210
QO215◆

QO310
QO315◆

–

–

QO220◆

QO320◆

–

QO One Pole

QO One Pole
Tandem

1 Space Required

1 Space Required

–

QO225◆
QO230◆
QO235◆
QO240◆
QO245◆
QO250◆
QO260◆
QO270◆
QO280
QO290
QO2100
QO2110
QO2125 No DC rating
QO2150◆▼
QO2175◆▼
QO2200◆▼

QO325◆
QO330◆
QO335◆
QO340◆
QO345◆
QO350◆
QO360◆
QO370
QO380
QO390
QO3100

QO215VH
QO220VH
QO225VH
QO230VH
QO240VH
QO250VH
QO260VH
QO270VH
QO280VH
QO290VH
QO2100VH
QO2110VH
QO2125VH
QO2150VH❒◆▼
QO2175VH❒◆▼
QO2200VH❒◆▼

QO315VH
QO320VH
QO325VH
QO330VH
QO340VH
QO350VH
QO360VH
QO370VH
QO380VH
QO390VH
QO3100VH

DE1

10
15
15
20
20
25
30
35
40
45
50
60
70
80
90
100
110
125
150
175
200

–
–
–
–
–

22,000 AIR
15
20
25
30
40
50
60
70
80
90
100
110
125
150
175
200
42,000 AIR
40
45
50
60
70
80
90
100
110
125
65,000 AIR
15
20
25
30

QO115VH▲
QO120VH▲
QO125VH
QO130VH

–
–
–
–
–
–
–
–
–
–
–
–

–
–
–
–
–

QOH240
QOH245
QOH250
QOH260
QOH270
QOH280
QOH290
QOH2100
QOH2110
QOH2125

—
—
—
—
—
—
—
—
—
—

QH115▲
QH120▲
QH125
QH130

QO Two Pole

2 Spaces Required

—
—
—
—
—
—
—
—
—
—

QH215
QH220
QH225
QH230

QO Three Pole

QH315
QH320
QH325
QH330

Tandem (Dual) Circuit Breakers 10,000 AIR
Ampere Rating '

One Pole - 120/240Vac

Two Single Pole Individual Trip - 120/240Vac

1 Space Required

2 Spaces Required

15 & 15
15 & 20
15 & 30
20 & 15
20 & 20
20 & 30
30 & 15
30 & 20
30 & 30

QO1515◆
QO1520◆
QO1530◆
QO2015◆
QO2020◆
QO2030◆
QO3015◆
QO3020◆
QO3030◆

Order Two QO1515 or QO2020 Circuit Breakers
and Handle Tie Catalogue # QOTHT.

'
‡
▲
◆
▼
❒

3 Spaces Required

10-30 ampere breakers are suitable for use with 60°C or 75°C conductors. 35-125 ampere breakers are suitable for use with 75°C conductors.
High magnetic trip breakers are recommended for applications where high initial inrush current may occur.
SWD (switching duty) rated. Suitable for switching 120Vac fluorescent lighting loads.
HACR type for use with air conditioning, heating and refrigeration equipment having motor group combinations and marked for use with HACR type
circuit breakers. HACR labelled one pole QO breakers not stocked. Order Only. Add suffix -5385.
Requires four spaces (#1-300 kcmil Al/Cu). Not suitable for use in 3-phase panel. Use only in single phase panel rated 150A or greater.
CSA Listed for use ahead of QO, QO-GFI, QO-EPD, QOT and QO-PL 10,000 AIR circuit breakers to permit their application at 22,000A fault level.

Application Information
• VISI-TRIP indication on all QO breakers.
• QO, VISI-TRIP and QWIK-GARD are registered trademarks of Square D.
• For more information consult Schneider Electric.
08/16

LOAD CENTRES

QO® Standard and Tandem Circuit Breakers

• Accessories page DE1-11.
• Add suffix 35 for 50°C calibration - 20% price adder.

DE1-5

QO® Loadcentres and Circuit Breakers
QO® Special Breakers

DE1

LOAD CENTRES

Plug-On Circuit Breakers - Amperes Interrupting Rating (AIR) in Amperes RMS Symmetrical

One Pole
QO-CAFI(PON)

QO-GFI

One Pole
QO-DF(PON)

One Pole
QO-GFI

Two Pole
QO-GFI

QWIK-GARD® circuit breakers provide overload and short circuit protection,
combined with Class A ground fault protection. Class A denotes a ground fault
circuit interrupter that will trip when a fault current to ground is 6 milliamperes
or more, for people protection. Do not connect to more than 250 feet of load
conductor for the total one-way run to prevent nuisance tripping.

One Pole
120Vac

Two PoleCommon Trip
120/240Vac

Three PoleCommon Trip
120/240Vac

Ampere
Rating '

10,000 AIR

22,000 AIR

10,000 AIR

10,000 AIR

15
20
25
30
40
50
60

QO115GFI
QO120GFI
QO125GFI
QO130GFI
—
—
—

QO115VHGFI
QO120VHGFI
QO125VHGFI
QO130VHGFI
—
—
—

QO215GFI
QO220GFI
QO225GFI
QO230GFI
QO240GFI
QO250GFI
QO260GFI❖

QO315GFI
QO320GFI
—
QO330GFI
QO340GFI
QO350GFI

❖ Suitable only for feeding 240Vac and 208Vac 2 wire loads.
Does not contain load neutral connection.
QO-EPD
Ampere
Rating '
15
20
25
30
40
50
60

QO-K

QO Circuit Breakers With 30 mA Equipment Ground Fault Protection

One Pole
120Vac

Two Pole-Common Trip
120/240Vac

10,000 AIR

10,000 AIR

QO115EPD
QO120EPD
QO125EPD
QO130EPD

QO215EPD
QO220EPD
QO225EPD
QO230EPD
QO240EPD
QO250EPD
QO260EPD

—
—
—

Key operated QO circuit breakers are available in single pole construction and
can be mounted in any single pole space which will accept a standard QO.
These circuit breakers can be turned ON or OFF or to RESET with a special
key (Catalogue Number QOK10) included with the circuit breaker.

Ampere
Rating '

One Pole 120Vac
10,000 AIR

10
15
20
30

QO110K
QO115K
QO120K
QO130K

QO-HM

QO circuit breaker with high magnetics to withstand higher inrush currents than
standard QO breaker.

Ampere
Rating

One Pole 120Vac
10,000 AIR

15
20

QO115HM
QO120HM

QO Combination Arc-Fault Interrupter (CAFI)
QO Combination Arc-Fault Interrupter (CAFI) provides overload and short circuit protection,
plus both series and parallel type arc protection as required in 2015 CEC. Integrated with Time
Saver diagnostics, QO CAFI breaker improves circuit troubleshooting at the touch of a button.,

Circuit Breaker Ampere
Type
Rating

1P 120 Vac
10K AIR
1 Space
Required

1P 120 Vac
22K AIR
1 Space
Required

2P 120/240 Vac 2P 120/240 Vac
10K AIR
22K AIR
2 Space
2 Space
Required
Required

QO Pigtail
Neutral CAFI

15

QO115CAFI

QO115VHCAFI

QO215CAFI* QO215VHCAFI*

20

QO120CAFI

QO120VHCAFI

QO220CAFI* QO220VHCAFI*

QO Plug-on
Neutral CAFI

15

QO115PCAFI QO115VHPCAFI

20

QO120PCAFI QO120VHPCAFI

* Rated for 120/240 ~60Hz, not for 208Y/120V

QO Dual Function Circuit Breaker
QO Dual Function (DF) breaker provides both combination arc-fault and ground-fault (5mA
classA) protection in a single compact device. Integrated with Plug-on Neutral and Time
Saver Diagnostics features, QO DF breaker offers maximum circuit protection and installation
flexibility.

Circuit Breaker Type

Ampere
Rating

1P 120 Vac 10k AIR 1P 120 Vac 22k AIR
1 Space Required
1 Space Required

QO Dual Function
Circuit Breaker with
Pigtail Neutral

15

QO115DF

QO115VHDF

20

QO120DF

QO120VHDF

QO Plug-on Neutral
Dual Function Circuit
Breaker

15

QO115PDF

QO115VHPDF

20

QO120PDF

QO120VHPDF

QO-HID Circuit Breakers -

QO-HID For Use on High Intensity Discharge Lighting Systems
HID circuit breakers are for use on circuits feeding fluorescent and High Intensity Discharge
(HID) lighting systems such as mercury vapour, metal halide, or high pressure sodium. These
circuit breakers are physically interchangeable with QO circuit breakers.

Ampere
Rating '
15
20
25
30
40
50

One Pole Two Pole-Common Trip Three Pole-Common Trip
120/240Vac
120/240Vac
240Vac
10,000 AIR
10,000 AIR
10,000 AIR
QO115HID▲
QO215HID
QO315HID
QO120HID▲
QO220HID
QO320HID
QO125HID
QO225HID
QO325HID
QO130HID
QO230HID
QO330HID
QO140HID
QO240HID
—
QO150HID
QO250HID
—

Note:
QO GFI, EPD, AFI, CAFI, and DF cannot be backfed.

Application Information
• VISI-TRIP indication on all QO breakers.
• QO, VISI-TRIP and QWIK-GARD are registered trademarks of Square D.
• For more information consult Schneider Electric.

DE1-6

08/16

QO® Loadcentres and Circuit Breakers
QO® Special Breakers

QO
1 Pole
QO
2 & 3 Pole
QOT
QO-GFI
& QO-EPD

Aluminum

Copper

10-30
10-30
35-70
10-30
35-70
80-125
15-20
15-30
40-60

#14-8
—
#8-2
#14-8
#8-2
#12-2/0
#12-8
#12-8
#12-4

#14-8
(2) #14-10
#8-2
#14-8
#8-2
#12-2/0
#14-8
#14-8
#14-6

Requires Additional Pole Space. Only one accessory per breaker. QO accessory terminals
for (2) #14-12 Cu. Accessories are not available for Q2, QOM1, or QOB-VH (110-150 A) circuit
breakers or QO molded case switches.

Factory
Installed
Accessories

Shunt Trip

Auxiliary
Switch
Alarm Switch

Main Breakers
Main Breaker
Amperage ✚
Frame Size

QOM1 '

QOM2▲

▲
✚

'

08/16

'

30
40
50
60
50
60
70
80
100
125
100
125
150
175
200
225

kAIC

10

22

22

Catalogue
Number
QOM30L
QOM40L
QOM50L
QOM60L
QOM50VHL
QOM60VHL
QOM70VHL
QOM80VHL
QOM100VHL
QOM125VHL
QOM2100VHL
QOM2125VHL
QOM2150VHL
QOM2175VHL
QOM2200VHL
QOM2225VHL

Lug Wire Size
AWG/KCMIL
Al or Cu

'
▲
✱

Available
On Breaker

QO

QO,-GFI,-EPD,
QO,-GFI,-EPD,

Description
120Vac
208Vac
240Vac
12Vac
24Vdc
12Vdc
24Vac
“A” Contact
“B” Contact
120Vac

Add Suffix
To Breaker
Catalogue No.
1021

1042
1200
1201
2100

10-30 ampere breakers are suitable for use with 60°C or 75°C conductors,
35-60 ampere breakers are suitable for use with 75°C conductors.
SWD (switching duty) rated. Suitable for switching 120Vac fluorescent
lighting loads.
Combination AFI devices provide protection against both high-energy paral
lel arcing (same as existing branch/feeder AFCI’s) and low energy (5A)
series arcing.

#12-2/0

#4-250

Add suffix - 1021 for 240Vac shunt trip. Factory Installed Accessory
Do not exceed the load centre mains rating.
Main Breakers include factory installed handle padlock attachment (padlock
QOM main circuit breaker in the 'off' position).

QO One Pole
with Shunt Trip

QOK Key
Operated

DE1-7

LOAD CENTRES

Breaker
Type

Circuit Breaker Factory Installed Accessories
Wire Size (AWG)

Ampere
Rating '

DE1

Circuit Breaker Wire Sizes

QO® Loadcentres and Circuit Breakers
QO® Main Lugs Loadcentres - Type 1 Indoor
QO® Main Lugs Loadcentres (1Ø - 3W)
LOAD CENTRES

Mains
Ampere
Rating
30

DE1

70

100

125
200
225

Number of Circuits
Standard
QO
1
2
2
4
6
8
12
16
24
32
40
32
40
42
60

Tandem
QO
2
4
4
8
12
15
24
32
48
48
48
64
80
80
80

Loadcentre
Catalogue Number
QO1L30S●
QO2L30SC●
QO2L70S✚ '
QO4L100S▲
QO6L100S/F▲
QO8L100S/F▲
CQO112L100GC
CQO116L100GC
CQO124L125GC
CQO132L125GC
CQO140L125GC
CQO132L200GC
CQO140L200GC
CQO142L225GC
CQO160L225GC

Trim
Catalogue Number
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included
Included◆

Loadcentre
Catalogue Number
QO403L100S '
QO312ML1
QO320ML1
QO324ML2
QO330ML2
QO342ML2

Trim
Catalogue Number
Included
QOC16UC
QOC24UC
QOC30UC
QOC30UC
QOC42UC

Main Wire Size
Al or Cu
(AWG/MCM)
12-10 Al or 14-10 Cu
12-10 Al or 14-10 Cu
12-3 Al or 14-4 Cu
8-1
8-1
8-1
4-1
4-1
4 - 2/0
4 - 2/0
4 - 250
4 - 250
4 - 250
4 - 300
4 - 300

Box Size
(see page 16)
1
2
3
4
4
4
6
7
8
9
11
11
11
12
14

Main Wire Size
Al or Cu
(AWG/MCM)

Box Size
(see page 16)

12-1 Al or 14-1 Cu
4 - 2/0
4 - 2/0
4 - 250
4 - 250
4 - 300

5
7
8
10
10
12

Main Wire Size
Al or Cu
(AWG/MCM)

Box Size
(see page 16)

#14-8
#8-2
#14-8
#8-2

4
4
6
6

#4-250
#4-250
#4-250
#4-250

12
12
12
12

QO® Main Lugs Loadcentres (3Ø - 4W)
Mains
Ampere
Rating
100
125
125
200
225

Number of Circuits
Standard
QO

Tandem
QO

3▼
12▼
20▼
24▼
30▼
42▼

24
40
48
60
60

QO® Generator Panel (1Ø - 3W)
Mains
Ampere
Rating

Total Number of Circuits
Standard
QO

Tandem
QO

Number of circuits available
for (generator) critical loads
Standard
QO

Tandem
QO

4
4
18
18

8
8
36
36

Loadcentre
Catalogue Number
CQO48M30DSGP
CQO48M60DSGP
QOGP3P3036
QOGP3P6036

18
18
18
18

36
36
36
36

QOGP3P604436200
QOGP3P604436150
QOGP3P604436125
QOGP3P604436100

30
60
30
60

QO® ‘all-in-one’ SE Generator Panels
200
150
125
100

'
●
✚
▲
◆
▼

•
•
•

40
40
40
40

80
80
80
80

Service entrance approved.
Will not accept QO-GFI or QO-EPD breakers.
Maximum 20A QO-GFI breaker or AFI breaker.
Maximum 70A branch breaker.
Does not include a door. Order kit # QODK60-2.
Shunt trip feature not available on any 3Ø loadcentres.
Feed-thru lugs cannot be added in filed-use QO3125SL
to feed-thru to another loadcentre.
Bus on 2-8 cct loadcentres is one piece, solid aluminum.
Bus on 12-60 cct loadcentres is one piece, tin plated
copper
Neutral terminals, main and ground lugs on all devices
are Aluminum.

Application Information
• All loadcentres are suitable for both flush or surface
mounting, unless suffixed:
- F - flush mounting only.
- S - surface mounting only.
• All Type 1 loadcentres are approved for vertical, horizon
tal, or inverted mounting.

DE1-8

• All 100A loadcentres are approved for 100A max. QO
branch circuit breakers.
• All 125A loadcentres are approved for 125A max. QO
branch circuit breakers.
• The maximum QO branch circuit breaker is 70 ampere
(single pole), 200 ampere (two pole) and 100 ampere
(three pole). Two pole QO breakers rated 150 - 200
ampere are restricted to Square D QO Single Phase load
center, Series G1.

• Main lugs loadcentres cannot be field converted to ser
vice entrance approved, main breaker loadcentres.
• QO is a registered trademark of Square D.
• For more information, consult Schneider Electric.
• GC includes ground bar combination surface/flush cover.

08/16

QO® Loadcentres and Circuit Breakers
QO® Main Breaker Loadcentres - Type 1 Indoor

Main Breaker
Amps

Number of Circuits
Standard
QO

Tandem
QO

Loadcentre
Catalogue Number

Trim
Catalogue Number

12
12
16
16
24
24
32
32
40
40

24
24
32
32
48
48
54
54
54
54

CQO112M100C60
CQO112M100C100
CQO116M100C60
CQO116M100C100
CQO124M125C60
CQO124M125C100
CQO132M125C100
CQO132M125C125
CQO140M125C100
CQO140M125C125

32
40
60

64
80
80

Main Wire Size
Al/Cu (AWG/MCM)

Box Size
(see page 16)

Included
Included
Included
Included
Included
Included
Included
Included
Included
Included

4-1
4-1
4-1
4-1
4 - 2/0
4 - 2/0
4 - 2/0
4 - 2/0
4 - 2/0
4 - 2/0

6
6
7
7
8
8
9
9
11
11

CQO132M200C
CQO140M200C
CQO160M200C●

Included
Included
Included◆

4 - 250
4 - 250
4 - 250

11
11
14

Loadcentre
Catalogue Number

Trim
Catalogue Number

Main Wire Size
Al or Cu (AWG/MCM)

Box Size
(see page 16)

QO324MB100
QO342MQB200

QOC30UC
QOC342UQC

4 - 250
4 - 250

10
13

Main Breaker Factory Installed
100
100
100
100
125
125
125
125
125
125

60
100
60
100
60
100
100
125
100
125

Main Breaker Factory Installed
200

200

225

200

Main Breaker Loadcentres (3Ø - 4W)
Number of Circuits
Bus
Ampere Rating

Main Breaker
Amps

Standard
QO

Tandem
QO

Main Breaker Factory Installed (QO3100VH & QDL32200)
100
200

100
200

24
42

30
60

◆

Does not include a door. Order kit # QODK60-2.

●

Rated 200A maximum with Aluminum conductors and 225A
maximum with Copper conductors.

•
•

Bus on all devices is one-piece, solid copper, standard.
Neutral terminals, main and ground lugs on all devices are
Aluminum, standard.

NQ Service Entrance Main Breaker Panelboards
Main Rating

300A

400A

Catalogue Number

1 or 3 Phase

NQSE142300F
NQSE184300F
NQSE142300S
NQSE184300S
NQSE142400F
NQSE342400S
NQSE184400F
NQSE372400S

1 phase
1 phase
1 phase
1 phase
1 phase
3 phase
1 phase
3 phase

Space
Standard QO Tandem QO
42
84
84
120
42
84
84
120
42
—
—
42
—
84
72
—

Factory Installed
Main Breaker

Enclosure Width

Trim Type

LAP26300MB
LAP26300MB
LAP26300MB
LAP26300MB
LAL26400
LAL36400
LAL26400
LAL36400

20”
20”
20”
20”
20”
20”
20”
20”

Flush
Flush
Surface
Surface
Flush
Surface
Flush
Surface

Application Information
• All loadcentres are suitable for both flush or surface
mounting.
• All Type 1 loadcentres are approved for vertical,
horizontal, or inverted mounting.
• All 100A loadcentres are approved for 100A max. QO
branch circuit breakers.
08/16

• All 125A loadcentres are approved for 125A max. QO
branch circuit breakers.
• The maximum QO branch circuit breaker is 70 ampere
(single pole), 200 ampere (two pole) and 100 ampere
(three pole). Two pole QO breakers rated 150 - 200
ampere are restricted to Square D QO Single Phase load
center, Series G1.

• Main Breaker loadcentres are approved for service
entrance use. The main breaker compartment can be
sealed and the main breaker can be locked.
• QO-L main breakers are 10 kAIC rated, QO-VHL main
breakers are 22 kAIC rated.
• QO is a registered trademark of Square D.
• For more information, consult Schneider Electric.

DE1-9

DE1

Bus
Ampere Rating

LOAD CENTRES

Main Breaker Loadcentres (1PH - 3W)

QO® Loadcentres and Circuit Breakers
QO® Main Lugs/Main Breaker Loadcentres - Type 3R Weatherproof

LOAD CENTRES

Main Lugs Loadcentres (1Ø - 3W)
Number of Circuits

Bus
Ampere
Rating

Box Size
(see page 16)

12-3 Al or 14-4Cu
8-1
8-1
4-1
4-2/0
4-250

1RB
2RB
2RB
6RB
6RB
8RB

Main Wire Size
Al or Cu
(AWG/MCM)

Box Size
(see page 16)

Tandem
QO

Loadcentre
Catalogue Number

Trim
Catalogue Number

2
6
8
16
24
40

4
12
15
32
48
80

QO2L70RB ✚ '✗
QO6L100RB
QO8L100RB
CQO116L100GRB
CQO124L125GRB
CQO140L200GRB

Included
Included
Included
Included
Included
Included

Tandem
QO

Loadcentre
Catalogue Number

Trim
Catalogue Number

QO403L100RB '
QO312ML1RB
QO320ML1RB
QO330ML2RB
QO342ML2RB

Included

12-1 Al or 14-1 Cu

3RB

Included
Included
Included
Included

4-2/0
4-2/0
4-250
4-300

4RB
5RB
7RB
9RB

Loadcentre
Catalogue Number

Trim
Catalogue Number

Main Wire Size
Al/Cu
(AWG/MCM)

Box Size
(see page 16)

70
100
125
200

DE1

Main Wire Size
Al or Cu
(AWG/MCM)

Standard
QO

Main Lugs Loadcentres (3Ø - 4W)
Number of Circuits

Bus
Ampere
Rating

Standard
QO

100

3

125
125
200
225

12
20
30
42

24
40
60
60

Main Breaker Loadcentres (1Ø - 3W)
Bus
Ampere Rating

Number of Circuits

Main
Breaker
Amps

Standard
QO

Tandem
QO

Main Breaker Factory Installed
100
100
125

60
100
100

8
16
24

16
32
48

CQO18M100RB60
CQO116M100RB100
CQO124M125RB100

Included
Included
Included

4-1
4-1
4 - 2/0

4RB
6RB
6RB

40

80

CQO140M200RB

Included

4-250

8RB

Loadcentre
Catalogue
Number

Trim
Catalogue Number

Main Breaker Factory Installed
200



200

Non-Metallic Enclosure (1Ø - 3W) Type 3R
Bus
Ampere Rating
60

Number of Circuits
Standard
QO
2

Tandem
QO
4

CQO24L60NRNM

Included

Main Wire Size
Al/Cu
(AWG/MCM)

Box Size
(see page
15)

#14-4 / #14-4

1NM

QO Hot Tub / Pool / Spa Pack

20 to 60 amp non-metallic

✚
▼

2 pole QOGFCI factory
installed into a
type 3R enclosure

CQOE220GFINM
CQOE230GFINM
CQOE240GFINM
CQOE250GFINM
CQOE260GFINM▼

'
✗

Maximum 20 A QO-GFI breaker.
60 amp, 2 wire 240V only. Not for hot tubs with neutral connection.
Service Entrance approved.
Not rated for 22k AIC.

•
•
•

Bus on 2-8 cct loadcentres is one-piece, solid aluminum. (Excluding CQO18M100RB.)
Bus on 8-42 cct, S-Series loadcentres is one-piece, solid copper.
Neutral terminals, main and ground lugs on all devices are Aluminum.

Application Information
• All 100A loadcentres are approved for 100A max. QO
branch circuit breakers.
• All 125A loadcentres are approved for 125A max. QO
branch circuit breakers.
• The maximum QO branch circuit breaker is 70 ampere
(single pole), 200 ampere (two pole) and 100 ampere

DE1-10

(three pole). Two pole QO breakers rated 150 - 200
ampere are restricted to Square D QO Single Phase load
center, Series G1..
• Main Breaker loadcentres are approved for service
entrance use. The main breaker compartment can be
sealed and the main breaker can be locked.

• Main lugs loadcentres cannot be field converted to ser
vice entrance approved, mainbreaker loadcentres.
• Weatherproof Loadcentres are supplied with main entry
hole cut in top endwall and closing cap (BCAP) installed.
Hole accepts 3/4 in. to 2 in. hubs. Gasket not required.
• QO is a registered trademark of Square D.
08/16

QO® Loadcentres and Circuit Breakers
QO® Plug-on Neutral Loadcentres

Number of Circuits
Standard
QO

Tandem
QO

Trim

Main Wire Size
Al/Cu
(AWG/MCM)

Box Size
(see page 16)

CQO124L125GCPON

Included

4 - 2/0

8

CQO124M125C100PON
CQO130M225C100PON
CQO142M225C100PON
CQO142M200CPON
CQO160M200CPON*
CQO124M125RB100PON

Included
Included
Included
Included
Included
Included

4 - 2/0
4 - 2/0
4 - 2/0
4 - 250
4 - 250
4 - 2/0

8
10
12
12
14
6RB

Loadcentre
Catalogue Number

Main Lugs Loadcentres (1Ø - 3W)
125

24

47

Main Breaker Loadcentres (1Ø - 3W)
Indoor

Outdoor
*

'

08/16

100
100
100
200
200
100

24
30
42
42
60
24

47
60
80
80
80
47

Does not include a door. Order kit # QODK60-2.
Plug-on Neutral loadcentres accept both pig-tail and Plug-on Neutral breakers

DE1-11

DE1

Mains Rating
Amps

LOAD CENTRES

QO Plug-on Neutral Loadcentres

QO® Loadcentres and Circuit Breakers
QO® Recreational Vehicle Park Loadcentres (ServicePak®)
QO® Mobile Home and Trailer Loadcentres

LOAD CENTRES

Recreational Vehicle Park Loadcentres (ServicePak® Panels)

DE1

Power
Ampere Rating
Outlet
Canada
Config.
Catalogue No.
Mains
Sub-feed
Spaces
Service
Underground or Overhead Loop-Feed Terminals - Non-Pedestal Mounted ◆
40

40

2

A

1Ø2W

50

50

2

B

1Ø2W

75

75

3

C

1Ø2W

QO2RV40A
QO2RV40AG
QO2RV50B
QO2RV50BG
QO2RV50BGFI
QO3RV75C
QO3RV75CG
QO3RV75CGFI

Main Wire Size
(AWG/MCM)
Al
Cu

Series

Box Size
(see page 16)

E01

14 - 6

12 - 6

RVP1

E01

14 - 6

12 - 6

RVP1

E01

14 - 1

12 - 1

RVP2

Underground Loop-Feed Terminals - Pedestal Mounted ●

•
•
•
•
•

50

200

2

B

1Ø2W

75

200

3

C

1Ø2W

100

200

4

D

1Ø3W

QO2RVP50B
QO2RVP50BG
QO2RVP50BGFI
QO3RVP75C
QO3RVP75CG
QO3RVP75CGFI
QO4RVP100D
QO4RVP100DG
QO4RVP100DGFI

Provide electrical power to individual recreational vehicle park sites.
Each receptacle protected by appropriate GFI or Standard QO® circuit breaker.
All receptacles and circuit breakers included.
10,000 RMS Symmetrical Ampere short circuit current rating.
All enclosures are rainproof.

•
•
•
•
•

E01

6 - 250

RVP1+Pedestal

E01

6 - 250

RVP2+Pedestal

E02

6 - 250

RVP2+Pedestal

No neutral bonding provisions.
Loop-Feed provisions.
Type 3R weatherproof.
Optional configurations not available.
Pedestal is factory installed only.

Power Outlet Configurations - Description
Configuration

A

B

C

T

T

T T

D

T

Receptacles

Catalogue Number Suffix

Canada Catalogue No.

configuration A
non-pedestal

STANDARD DEVICE - 2xQO115 + 2x 15A 120v recpt
G = 2xQO115GFI factory installed

QO2RV40A
QO2RV40AG

configuration B
non-pedestal

STANDARD DEVICE - 1xQO115+ 1xQO130 + 1x15A,1x30A 120v recpt
G = 1xQO115GFI & 1xQO130 factory installed
GFI = 1xQO115GFI & 1XQO130GFI factory installed

QO2RV50B
QO2RV50BG
QO2RV50BGFI

configuration C
non-pedestal

STANDARD DEVICE - 1xQO115+ 2xQO130 + 1x15A, 2x30A 120v recpt
G = 1xQO115GFI & 2xQO130 factory installed

QO3RV75C
QO3RV75CG

configuration B
pedestal

STANDARD DEVICE - 1xQO115+ 1xQO130 + 1x15A,1x30A 120v recpt
G = 1xQO115GFI & 1xQO130 factory installed
GFI = 1xQO115GFI & 1XQO130GFI factory installed

QO2RVP50B
QO2RVP50BG
QO2RVP50BGFI

configuration C
pedestal

STANDARD DEVICE - 1xQO115+ 2xQO130 + 1x15A, 2x30A 120v recpt
GFI = 1xQO115GFI & 2xQO130GFI factory installed

QO3RVP75C
QO3RVP75CGFI

configuration D
pedestal

STANDARD DEVICE - 1xQO115+ 1xQO130 + 1xQO250
+ 1x15A, 1x30A 120v recpt & 1x50A 120/240v recpt
G = 1xQO115GFI & 1xQO130 & 1xQO250 factory installed
GFI = 1xQO115GFI & 1x10130GFI & 1xQO250 factory installed

QO4RVP100D
QO4RVP100DG
QO4RVP100DGFI

Mobile Home and Trailer Loadcentres
Mains Ampere
Rating

Spaces

Service

Catalogue
Number

Main Wire Size (AWG/MCM)
Series

Al

Cu

Box Size
(see page 16)

Main Lugs Loadcentres

◆
◆
●
‡
✚
†

30
2
1Ø2W
QO2L30TTS ‡
G01
12 - 10
14 - 10
MH1
50
2
1Ø2W
QO24L50TTS ✚
G01
—
14 - 6
MH2
70
2
1Ø3W
QO24L70TS
G01
12 - 3
14 - 4
MH2
100
6
1Ø3W
QO612L100TF/S †
G01
4-1
MH3
100
6
1Ø3W
QO612L100DTF/S †
G01
4-1
MH3
Non-pedestal devices are supplied with main entry hole cut in top endwall and have closing cap (BCAP) installed. Hole accepts 3/4 in. to 2 1/2 in. hubs. Gasket not required.
Non-pedestal devices have provisions to field install a Type “B” bolt on hub on the bottom endwall. For bottom feed from a conduit riser, order Type “B” hub and two mounting screws P/N:
8002505501; and two hex nuts, P/N: 2340102000.
For pedestal devices, a stabilizer foot is available for use in unstable ground, P/N: HNPSF.
Will not accept QO-GFI circuit breakers.
Use #10 maximum size wire for QO-GFI circuit breakers.
70A Max. branch circuit breaker and 70A Max. back fed main circuit breaker.

Application Information
• All Servicepak® Panels have their breakers and
receptacles factory installed and prewired.
• Mobile Home and Trailer Loadcentres do not come with
factory installed breakers. Order separately.
• Servicepak® Panels and Mobile Home and Trailer Load
centres are not suitable for use as service equipment.

DE1-12

• All Servicepak® devices are set up for Loop-fed,
therefore, there are 2 wires per phase, neutral and
equipment ground.
• Servicepak® devices are suitable for surface mounting
only.

• Power Outlet Configurations, other than those shown
above, are not available.
• Servicepak® is a Registered Trademark of Square D.
• For more information, consult Schneider Electric.

08/16

QO® Loadcentres and Circuit Breakers
Accessories
Description

Catalogue Number

Converts any two adjacent 120/240Vac single pole QO breakers to independent trip two pole .......................... QO1HT
Converts any two adjacent 120/240Vac single pole side-by-side Tandem breakers to independent trip two pole QOTHT
Handle Lock-Off:
Clamp for holding QO single pole handle in “ON” or “OFF” position.................................................................... QO1LO
Clamp for holding QO, either 1, 2 or 3-pole breaker handles in “ON” or “OFF” position ...................................... HLO1
Handle Padlock Attachment:
For padlocking single pole QO breaker in “ON” or “OFF” position
Loose Attachment
QOHPL
Fixed Attachment
QO1PA
For padlocking single pole side-by-side QO Tandem breaker in “ON” or “OFF” position.... ................................. QOTHPA
For 2 and 3-pole QO breakers which require padlocking in either “ON” or “OFF” position
Loose Attachment........................................................................................................................................ . QO1HPL
Fixed Attachment........................................................................................................................................ .. QO1PL
For padlocking QOM main circuit breakers in “OFF”...............................................................50-125A... ........... . QOM1PA
150-225A... ...................................................................................................................................................... .... QOM2PA
For padlocking 2-Pole QO-GFI in either “ON” or “OFF” position.......... .............................................. .................. GFI2PA
Mechanical Interlock Attachment: For interlocking the handles of two 2-pole or one 2-pole and one 1-pole QO breakers mounted side-by-side
so that only one breaker can be “ON” at a time..... .............................................................................................. QO2DTI
125 ampere two pole plug-on – 2 spaces required (#12-2/0 Al/Cu)..................................................................... QO2125SL
Sub-feed lugs
125 ampere three pole plug-on – 3 spaces required (#12-2/0 Al/Cu) .................................................................. QO3125SL
Fills branch breaker openings in cover................................................................................................................. QOFP
Filler Plates
Fills QOM1 main breaker opening in cover...............................................................100-125A........................... . QOM1FP
Fills QOM2 main breaker opening in cover...............................................................150-225A........................... . QOM2FP
Fills main breaker opening in 3Ø covers (S-Series)............................................................................................. KFP

Lock Kits

Converts door latch from spring catch to lock type .............................................................................................. PK6FL

Neutral / Ground Lugs

Field installed for #12 to 2 Al or #14 to 4 Cu wire ................................................................................................
Field installed for #6 to 2/0 Al/Cu wire..................................................................................................................
Field installed for #14 to 2/0 Al/Cu wire................................................................................................................
Field installed for #2 to 3/0 Al/Cu wire..................................................................................................................
Field installed for #4 to 300 MCM Al/Cu...............................................................................................................

LK70AN
LK100AN
LK125AN
LK150AN
LK225AN

Neutral Extension kits

Field installed on 1ph QO loadcentres

See page DE1-12

Ground Bar Kits

Standard PK15GTA with a #1 to 4/0 Cu/Al Lug................................................................................................... . PK15GTAL
Standard PK18GTA with a #1 to 4/0 Cu/Al Lug................................................................................................. ... PK18GTAL
Standard PK23GTA with a #1 to 4/0 Cu/Al Lug................................................................................................... . PK23GTAL
Insulator Kit for PK9GTA thru PK27GTA.. .......................................................................................................... .. PKGTAB

Miscellaneous

QO main breaker barrier. .................................................................................................................................. ... 4055952201

Retaining Kit:

Secures circuit breaker to interior when used as a back-fed main.
For use on QO6L100S/F, RB and QO8L100S/F, RB Loadcentres. ................................................................... ... PK2MB
Secures circuit breaker to interior when used as a back-fed main. For 3Ø Loadcentres (S-Series)................... . PK3MB
Provides means of sealing trim mounting screws on QO load centre covers.. ................................................. ... QO1SE
For use on plug-on connectors only. Recommended for use whenever QO plug-on breakers are removed and
reinstalled for any reason. 57g container ............................................................................................................ . PJC7201
Aerosol spray paint can – ASA 49 ....................................................................................................................... W469X83

Cover Sealing Strap:
Joint Compound
Touch–up Paint

QO1HT
QO1PL
PK2MB

QO2DTI

PK3MB
QOSAMK
QO1LO

QO1PA

QOTHPA
QO1HPL

PKGTAB
QOFP
PK6FL

HLO1
HLO-1

Application Information
• QO is a registered trademarks of Square D.
• For more information consult Schneider Electric.
08/16

DE1-13

DE1

Handle Tie:

LOAD CENTRES

Handle Attachments

QO® Loadcentres and Circuit Breakers

DE1

LOAD CENTRES

QO® Single Phase Loadcentre - Field Installed Neutral Extension Kits

Loadcentre
catalogue number

Reference
neutral kit(s)*

Loadcentre
catalogue number

CQO124L125GC

1

CQO142L225GC

1 or 3

CQO124L125GRB

1

CQO160L225GC

2 , 3 or 4

CQO124M125C60

1

CQO160M200C

2 , 3 or 4

CQO124M125C100

1

CQO124M60CD

1

CQO124M125RB100

1

CQO124M100CD

1

CQO132L125GC

1

CQO132M100CD

1

CQO132L200GC

1

CQO132M125CD

1

CQO132M125C100

1

CQO140M200CD

2

CQO132M125C125

1

CQO112L100GC

–

CQO132M125C60

1

CQO116L100GC

–

CQO132M125C70

1

CQO116L100GRB

–

CQO132M200C

1

CQO116M100C60

–

CQO140L125GC

2

CQO116M100C100

–

CQO140L200GC

2

CQO116M100RB100

–

CQO140L200GRB

2

CQO18M100RB60

–

CQO140M125C100

2

CQO112M100C60

–

CQO140M125C125

2

CQO18M100RB100

–

CQO140M150C

2

CQO140M200C

2

CQO140M200RB

2

Reference
neutral kit(s)*

* Neutral kit reference number description
Reference neutral kit(s)

Neutral kit catalogue number

Neutral kit description

1

QONK1

14 neutral ports x 2

2

QONK2

22 neutral ports x 2

3

QONK3

34 neutral ports x 2

4

QONK4

41 neutral ports x 2

–

–

Neutral kit is not available

*Installing the Neutral Bar Extensions
When installing the QO neutral bar extension kits, circuit breaker mounting spaces need to be left
open below the neutral extension kits for ground fault interrupters, arc fault interrupters and the larger
amperage branch circuit breakers rated 150–200 A that would extend beyond the neutral bars.
These circuit breaker types will not fit over the OQ neutral extension kit bars.
QO neutral kit - customer opportunities
• Increased installation flexibility
• Enhanced retro-fit opportunities
QO neutral kit - advantages
• Multiple length kits available
• Kit includes a left and right side neutral bar
• Left side or right side installation option

Application Information
• For more information, contact our Customer Information Centre @ 1-800-565-6699.

DE1-14

08/16

QO® Loadcentres and Circuit Breakers
Secondary Surge Suppressors and Surge Arresters

LOAD CENTRES

SURGEBREAKER PLUS®

DE1

• Suitable for use in service entrance locations.
• Meets requirements of CSA C22.2 No. 8, UL 1449, 3rd Edition, ANSI/IEEE C62.41
and cULus Listed.
• AC line protection.
• Four line telephone protection.
• Two line coaxial protection.
• Suitable for indoor applications only.
• Flush or surface mounting.
• LED status indicator.
• Modular design with optional accessories.

Single Phase Three Wire – 120/240 Vac
Description

Catalogue Number

Surgebreaker Plus

SDSB80111C

SDSB80111C

SURGEBREAKER™ Secondary Surge Arrester
•
•
•
•
•

Suitable for use in service entrance locations.
Meets CSA C22.2 No. 8, CSA C233.1, ANSI/IEEE C62.11.
QO2175SB for QO load centers and combination devices, NQOD panelboards.
Plug–on design requires two pole spaces.
LED indicates operational status.
Description

QO Surgebreaker
cULus Listed
Secondary Surge Arrester
150Vac line–to–ground maximum

Catalogue
Number

QO2175SB

QO2175SB

Hard–Wired Secondary Surge Arresters
•
•
•
•
•

Suitable for use in service entrance locations.
cULus Listed Secondary Surge Arresters.
Meets CSA C233.1, ANSI/IEEE C62.11.
Suitable for indoor and outdoor applications.
LED indicates operational status.
Description

Catalogue
Number

SECONDARY SURGE ARRESTER
For 1Ø systems.
150Vac phase–to–ground maximum.

SDSA1175■

SECONDARY SURGE ARRESTER
for 3Ø systems.
600Vac phase–to–ground
maximum.●

SDSA3650

■
●

SDSA1175

SDSA3650

Catalogue Number QOSAMK required for installation in QO loadcentres (see page
DE1–11 for diagram).
Do not use on ungrounded systems. Systems must be
solidly grounded.

Application Information
• For more information, please refer to catalogue No. 6671CT9701.

08/16

DE1-15

QO® Loadcentres and Circuit Breakers

DE1

LOAD CENTRES

Enclosure Dimensions

Type 1 QO Loadcentre Enclosures
Type 1
Box Size

Height
(in./mm)

Width
(in./mm)

1

5.50/140

2

6.75/171

3
4

Type 3R QO Loadcentre Enclosures
Depth
(in./mm)

Type 3R
Box Size

Height
(in./mm)

Width
(in./mm)

Depth
(in./mm)

3.00/76

3.50/89

1NM

9.80/245

6.5/162.5

3.9/97.5

3.75/95

3.00/76

1RB

9.50/241

5.00/127

4.00/102

9.25/235

4.75/121

3.25/83

2RB

12.75/324

9.00/229

4.25/108

12.75/324

9.00/229

3.75/95

3RB

13.00/330

6.75/171

4.00/102
4.50/114

5

13.25/377

6.00/152

3.50/89

4RB

19.00/483

14.25/362

6

15.00/381

14.25/362

3.75/95

5RB

22.00/559

14.25/362

4.50/114

7

18.00/457

14.25/362

3.75/95

6RB

22.25/565

14.25/362

4.50/114

8

21.00/533

14.25/362

3.75/95

7RB

30.00/762

14.25/362

4.50/114

9

26.25/667

14.25/362

3.75/95

8RB

34.00/864

14.25/362

4.50/114

10

30.00/762

14.25/362

3.75/95

9RB

38.00/965

14.25/362

4.50/114

11

34.00/864

14.25/362

3.75/95

12

38.00/965

14.25/362

3.75/95

13

40.00/1016

14.25/362

3.75/95

14

41.25/1048

14.25/362

3.75/95

Recreational Vehicle Park Loadcentres
Box
Size

Mobile Home and Trailer Loadcentres

Height
(in./mm)

Width
(in./mm)

Depth
(in./mm)

Box
Size

Height
(in./mm)

Width
(in./mm)

Depth
(in./mm)

RVP1

8.50/216

7.75/197

5.80/147

MH1

RVP2

16.40/417

7.75/197

5.80/147

MH2

6.72/171

3.81/97

3.00/76

9.30/236

4.80/122

Pedestal

50.90/129

7.60/193

3.50/89

MH3

3.19/81

12.57/319

8.88/226

3.80/97

Application Information
• Dimensions for approximate only.
Do not use for construction.

DE1-16

08/16

Canadian HomeLine® Circuit Breakers and Loadcentres
General Information

Pages:

•

DE1-17 to DE1-34

Application:

•

Residential, Light Commercial

•

30 through 225 Amperes

•

CSA Certified under File

DE1

Standards:

LOAD CENTRES

Canadian HomeLine™ Single Phase Loadcentres

#LL-89066

Enclosures:

Features:

•

Type 1 and 3R

•

One piece, plated, shielded
aluminum bus
Split branch neutral with 3-1/0
“built in” branch neutral lugs
Combination Slot/Robertson neutral, ground and trim screws
Additional ground bar provisions

•
•
•

Accessories:

08/16

•

Trims have automatic flush
adjustment

•

Fusible loadcentre inserts
(HFLCI)

•

Secondary Surge Arresters

•

Sub-Feed Lugs

•
•

Filler Plates (for branch and main
breakers)
Door Lock Kits

•

Neutral Lugs

•

Neutral extension kits

DE1-17

Canadian HomeLine™ Circuit Breakers and Loadcentres
Product Description
The Residential Solution for Canadian Electrical Contractors
LOAD CENTRES

HomeLine™ circuit breaker loadcentres from Schneider Electric are CSA
certified panelboards. They are designed to meet residential requirements to
protect electrical systems, equipment, and people.

Features
Indoor (NEMA Type 1), Main Breaker, 12 to 60 spaces

DE1

•
•
•
•

HomeLine™ Main Breaker Loadcentre

•
•
•
•
•
•
•
•
•
•
•
•

Single phase, 120/240V
200A maximum tin plated aluminum bus
60 spaces, 120 circuits max
Short circuit rating
k

standard 22kAIC – main breaker (50A thru 200A)

k

series ratings up to 100kAIC

Distributed neutral bar design
Robertson/Slot neutral, ground and trim screws
Shielded bus bar
Appliance white combination flush/surface mount trim
Automatic flush trim adjustment with shutter type twistouts
Top or bottom feed
Multiple horizontal and vertical ground bar mounting positions
Straight in wiring for main and branch wiring
Removable interiors
Tangential main knockouts
Provision for optional door lock
Welded box construction

Indoor (NEMA Type 1), Main Lug, 2 to 42 spaces

•
•
•
•

•
•
•
•

Single phase, 120/240V
225A maximum tin plated aluminum bus
42 spaces, 84 circuits max
Short circuit rating
k

standard 10kAIC – main lug

k

series ratings up to 100kAIC

Robertson/Slot neutral, ground and trim screws
2 to 6 space single row loadcentres, ASA49 grey
Top or bottom feed
Welded box construction

HomeLine Fusible Loadcentre Inserts (HFLCI)
Indoor (NEMA Type 1), Main Lug, 12 spaces

Flush Cover

•
•
•
•

•
•

DE1-18

Single phase, 120/240V
125A maximum tin plated aluminum bus
12 spaces, 24 circuits max
Short circuit rating
k

standard 10kAIC

k

series ratings up to 100kAIC

Robertson/Slot neutral, ground and trim screws
Architectural white surface mount trim with door

08/16

Canadian HomeLine™ Circuit Breakers and Loadcentres
General Information and Application Data

•
•
•
•
•
•
•

Single phase, 120/240V
200A maximum tin plated aluminum bus
20 spaces, 40 circuits max
Short circuit rating
k

standard 22kAIC – main breaker

k

series ratings up to 100kAIC

DE1

•
•
•
•

LOAD CENTRES

Outdoor (NEMA Type 3R), Main Breaker,
8 to 20 spaces

Distributed neutral bar design
Robertson/Slot neutral, ground and trim screws
Shielded bus bar
Side hinged door
Welded, galvanealed steel, painted ASA49 grey enclosure
Gasketless rain hubs – 0.75” to 2.5”
Stainless steel locking hasp

Outdoor (NEMA Type 3R), Main Lug,
2 to 12 spaces

RB Device

•
•
•
•

•
•
•
•

Single phase, 120/240V
125A maximum tin plated aluminum bus
12 spaces, 24 circuits max
Short circuit rating
k

standard 10kAIC – main lug

k

series ratings up to 100kAIC

Robertson/Slot neutral, ground and trim screws
Welded, galvanealed steel, painted ASA49 grey enclosure
Gasketless rain hubs – 0.75” to 2.5”
Stainless steel locking hasp

Bolt-On Hubs

08/16

DE1-19

Canadian HomeLine™ Circuit Breakers and Loadcentres
General Information and Application Data

DE1

LOAD CENTRES

Main breakers, branch breakers and surge suppressors

CHOM 1-Pole
1 space required.

CHOM 2-Pole
2 spaces required.

•
•
•
•
•
•
•
•
•

CSA File # LL-89066
Accepts 60/75C wire up to 40A, 75C wire over 40A
HACR rated
SWD rating on 1” 15A and 20A breakers
1-pole and 2-pole
Standard – 1” per pole
Twin – 1/2” per pole
Quad – 1/2” per pole
Main breakers
k

•
•
•
•

15A thru 200A
Optional high magnetic on 1” 15A and 20A breakers
Subfeed lugs
k

•
•
CHOMT 1-Pole Tandem
1 space required.

CHOMT Quad Circuit Breaker
2 spaces required.

•

•
CHOM 1-Pole GFI
1 space required.

CHOM 2-Pole GFI
2 space required.

125A or 225A

Arc-fault circuit interrupters – 20A max
Combination arc-fault circuit interrupters – 20A max
k

•

30A thru 225A

Branch breakers

Senses series and parallel arcing

Ground fault circuit interrupters – 50A max
k

5mA Class A

k

30mA equipment protective devices

k

Spa packs

Accessories
k

handle lock offs

k

handle ties

k

branch filler plates

Plug-in surge suppressors
k

Electronic MOV technology

k

Plug-in or knockout mounted

Branch Circuit Breakers
10,000 AIR
CHOM

1-pole, 15–50 A
2-pole, 15–200 A

CHOMT

1-pole, 15–30 A
2-pole, 15–50 A

CHOM-GFI

1-pole, 15 & 20 A
2-pole, 15, 20, 30, 40, 50 A

CHOM-AFI
1 space required.

CHOM-AFI

1-pole, 15 & 20 A

CHOM-CAFI

1-pole & 2 pole, 15 & 20 A

CHOM-DF

1-pole, 15 & 20 A

QOM1 Frame Size
QOM2 Frame Size

DE1-20

08/16

Canadian Catalogue Number logic
HomeLine™ Loadcentres
Number Segment

Character

Description

Load Center Family

CHOM

CSA Listed

Spaces / Circuits

3060

CHOM

M

Main circuit breaker

L

Main lugs

G

Factory included

C

Combination flush / surface indoor cover

3060

L

200

G

—

C

LOAD CENTRES

Canadian HomeLine™ Circuit Breakers and Loadcentres
Product Description

DE1

Mains Type
Amps
Ground Bar

F

Flush

RB

Rainproof

S

Surface

Cover

HomeLine™ Circuit Breakers
Number Segment

Character Description

CHOM

1

CHOM

Full Size

CHOMT

Tandem/Quad

AFI

Arc fault circuit interruption

BB

High amp branch breaker

CAFI

Combination arc fault circuit interruption

EPD

Equipment protection device, 30mA

GFI

Ground fault circuit interruption, 5mA

HM

High magnetic trip

DF

Dual function

15

—

Brand
Number of Poles
Amps

Device Name

Notes:
1. CHOM 1pole - 1" wide, 1 space required.
2. CHOM 2pole - 2" wide, 2 spaces required.
3. CHOMT 1pole tandem - 1" wide, 1 space required,represents two 1pole circuit breakers, i.e. CHOMT1515.
4. CHOMT 2pole tandem quad - 2" wide, 2 spaces required, represents two 1pole outer poles and one 2pole inner circuit breaker with common trip,
i.e. CHOMT1515220.

08/16

DE1-21

Canadian HomeLine® Circuit Breakers and Loadcentres
Circuit Breakers and Accessories
Standard and Main Circuit Breakers

DE1

LOAD CENTRES

Standard Loadcentre Breakers

Amp
Rating

Type

1 Pole Cat.
No.

15
20
25
30
35
40
45
50
15
20
60
70
80
90
100
125
150
175
200

CHOM 1, 2 & 4

CHOM 5
high magnetic

CHOM 1 & 3

CHOM115
CHOM120
CHOM125
CHOM130
—
CHOM140
—
CHOM150
CHOM115HM
CHOM120HM
—
—
—
—
—
—
—
—
—

Lug Range

#14 - #8

#8-#2

#14-#8

—

—

2 Pole Cat. No. Lug Range
CHOM215
CHOM220
CHOM225
CHOM230
CHOM235
CHOM240
—
CHOM250
—
—
CHOM260
CHOM270
CHOM280
CHOM290
CHOM2100
CHOM2125
CHOM2150BB
CHOM2175BB
CHOM2200BB

#14 - #8

#8-#2

#4-2/0

#4-300mcm

Notes:
1. All CHOM 1 & 2 pole CSA listed as HACR type.
2. CHOM115 & 120 SWD rated.
3. CHOM2P150-2P200 require 4 spaces, use only in single phase loadcentres rated 150A or greater.
4. CHOM 1pole circuit breakers require one space. CHOM 2pole circuit breakers require two spaces.
5. High magnetic trip circuit breakers are recommended for applications where high initial inrush current may occur.

HomeLine Main Circuit Breakers

Type

QOM1

QOM2

DE1-22

Amp
Rating
30
40
50
60
70
80
100
125
100
125
150
175
200
225

2 Pole Cat No. kAIC Lug Range
QOM30L
QOM40L
QOM50VHL
QOM60VHL
QOM70VHL
QOM80VHL
QOM100VHL
QOM125VHL
QOM2100VHL
QOM2125VHL
QOM2150VHL
QOM175VHL
QOM2200VHL
QOM2225VHL

10
10

#12-2/0

22

QOM2
#4-300mcm

08/16

Canadian HomeLine™ Circuit Breakers and Loadcentres
Circuit Breakers and Accessories
CHOMT Breakers, Combination Arc Fault Circuit Interrupters, Dual Function Circuit Breakers

CHOMT Tandem & Quad Tandem Circuit Breakers

CHOMT
Tandem 1 & 3

CHOMT
Quad
Tandem 1, 2 & 4

CHOMT Tandem Cat. No.
15-15
15-20
20-20
30-15
30-20

Lug Range

CHOMT1515
CHOMT1520
CHOMT2020
CHOMT3015
CHOMT3020

HOMELINE

Amp Rating

15-30A
#14-#8

1P

2P

Quad CHOMT Tandem Cat. No.

(2)15A
(2)15A
(2)15A
(2)15A
(2)15A
(2)15A
(2)20A
(2)20A
(2)20A
(2)20A
(2)20A

15A
20A
25A
30A
40A
50A
20A
25A
30A
40A
50A

CHOMT1515215
CHOMT1515220
CHOMT1515225
CHOMT1515230
CHOMT1515240
CHOMT1515250
CHOMT2020220
CHOMT2020225
CHOMT2020230
CHOMT2020240
CHOMT2020250

DE1

Type

15-30A
#14-#8

40-50A
#6-12 Al #6-14 Cu

Notes:
1. CSA certified for use as HACR type circuit breakers.
2. Cat# represents two 1P outer poles and one 2P inner circuit breaker with common trip.
3. CHOMT tandems require 1 space.
4. CHOMT quad tandems require 2 spaces.

HomeLine Combination Arc-Fault Interrupter (CAFI)
HomeLine Combination Arc-Fault Interrupter (CAFI) provides overload and short circuit protection, plus both series and parallel
type arc protection as required in 2015 CEC. Integrated with Time Saver diagnostics, HomeLine CAFI breaker improves circuit
troubleshooting at the touch of a button.

Circuit Breaker Type

Ampere Rating

1P 120 Vac
10K AIR
1 Space Required

2P 120/240 Vac
10K AIR
2 Space Required

15

CHOM115CAFI

CHOM215CAFI*

20

CHOM120CAFI

CHOM220CAFI*

15

CHOM115PCAFI

20

CHOM120PCAFI

HomeLine Pigtail Neutral CAFI

HomeLine Plug-on Neutral CAFI

* Rated for 120/240V ~ 60 Hz, not for 208Y/120V

HomeLine Dual Function Circuit Breaker
HomeLine Dual Function (DF) breaker provides both combination arc-fault and ground-fault (5mA classA) protection in a single
compact device. Integrated with Plug-on Neutral and Time Saver Diagnostics features, HomeLine DF breaker offers maximum
circuit protection and installation flexibility.

Circuit Breaker Type

Ampere Rating

1P 120 Vac 10K AIR
1 Space Required
Catalog Number

HomeLine Dual Function Circuit Breaker with
Pigtail Neutral

15
20

CHOM120DF

HomeLine Plug-on Neutral Dual Function
Circuit Breaker

15

CHOM115PDF

20

CHOM120PDF

08/16

CHOM115DF

DE1-23

Canadian HomeLine™ Circuit Breakers and Loadcentres
Circuit Breakers and Accessories

HomeLine GFI with 5 mA Sensitivity (Class A)

Ground Fault Devices (GFI)

Amp
Rating

Spa Pack

1 Pole Cat. No.

15
20
30
40
50

DE1

LOAD CENTRES

Ground Fault Circuit Interrupters, Arc Fault Circuit Interrupters

2 Pole Cat. No.

CHOM115GFI
CHOM120GFI

CHOM215GFI
CHOM220GFI
CHOM230GFI
CHOM240GFI
CHOM250GFI

A complete kit consisting of a Type 3R enclosure, factory installed 2P50A
GFCI circuit breaker.

Spa Pack

Amp Rating
50

Poles

Cat. No.
2

CHOME250SPA

HomeLine EPD with 30 mA Sensitivity

Type

1 Pole Cat. No.
15
20
30
40
50

2 Pole Cat. No.

CHOM115EPD
CHOM120EPD

CHOM215EPD
CHOM220EPD
CHOM230EPD
CHOM240EPD
CHOM250EPD

Notes:
1. GFI breakers maximum 250 feet (one way) feeder length
2. Use solid conductor only when #14 wire is used

CHOM115GFI

CHOM230GFI

CHOM115PCAFI

CHOM215CAFI

CHOM115CAFI

Canadian HomeLine Breaker Accessories

Description

Cat. No.

Handle attachments
Handle tie, converts any 2 adjacent 1P HOM circuit breakers to independent trip 2P

HOM1HT

Handle tie, converts any adjacent 1P side by side HOMT CB's to independent 2P

HOMTHT

Handle lock, ON or OFF, nonpadlocking HomeLine 1p 15-50A CB

QO1LO

Handle blocking device, attaches to a HOM 2P CB for holding the handle in the OFF position

HOM2HBD

Handle lock, ON or OFF, padlocking HomeLine 1p 15-50A CB

HOM1PA

2 pole standard HomeLine handle lock ON or OFF, Padlocking
- Handle padlock attachment, for padlocking 2P 15-70A

HOM2PALA

- Handle padlock attachment, for padlocking 2P 80-125A

HOM2PAHA

- Handle padlock attachment, for padlocking 2P 150-200A

HOM2PAVHA

Handle Padlock Attachment, for padlocking 1P CAFI,DF, GFI, and EPD CHOM breakers in ON or OFF position

HOMELEC1PA

Handle Padlock Attachment, for padlocking 2P CAFI, GFI, and EPDC CHOM breakers in ON or OFF position

HOMELEC2PALA

Handle padlock attachment, for padlocking centre poles of HOM quad breakers in the OFF position

HOMQPA

Handle lock, OFF for QOM1 50-125A Main Circuit Breaker

QOM1PA

Handle lock, OFF for QOM2 100-225A Main Circuit Breaker

QOM2PA

Sub-feed Lugs
125A 2P plug-on - 2 spaces required

HOML2125

225A 2P plug-on - 4 spaces required

HOML2225

Note: Canadian HomeLine and QO loadcentre accessories may

DE1-24

08/16

Canadian HomeLine™ Circuit Breakers and Loadcentres
Type 1 Main Lug and Main Circuit Breaker Loadcentres

Maximum Number
of Circuits
Standard 1"

Tandem or
Quad

Loadcentre
Cover
Catalogue
Number

CHOM24L70F/S

2

4

Included

100

CHOM612L100F/S

6

12

Included

N

10,000 A

#8–1

4

Top

125

CHOM48L125GC

4

8

Included

N

10,000 A

#4–2/0

21

Top

Loadcentre
Catalogue Number

Service
Entrance
Approved

Maximum
Short
Circuit
Rating

N

10,000 A

Main
WireSize
AWG/kcmil
Al/Cu

Enclosure
No.
(Pages
34-35)

Top or
Bottom
Mains
Position

2

Top

Factory-Installed Main Lugs
70

#12–3
#14–4

Factory-Installed Main Lugs

125

CHOM816L125GC

8

16

Included

N

10,000 A

#6–2/0

6

Both

CHOM1224L125GC

12

24

Included

N

10,000 A

#6–2/0

6

Both

CHOM1632L125GC

16

32

Included

N

10,000 A

#6–2/0

8

Both

CHOM2448L125GC

24

48

Included

N

10,000 A

#6–2/0

8

Both

CHOM3060L125GC

30

60

Included

N

10,000 A

#6-2/0

10

Both

CHOM3060L225GC

30

60

Included

N

10,000 A

#6–250

10

Both

CHOM4284L225GC

42

84

Included

N

10,000 A

#6–250

12

Both

Factory-Installed Main Lugs
225

Single-Phase, Three-Wire, 120/240 Vac Main Circuit Breaker – Indoor
Mains
Rating
in
Amps

Loadcentre
Catalogue Number

Maximum Number
of Circuits
Standard 1"

Tandem or
Quad

Loadcentre
Cover
Catalogue
Number

Service
Entrance
Approved

Maximum
Short
Circuit
Rating

Main
WireSize
AWG/kcmil
Al/Cu

Enclosure
No.
(Pages
34-35)

Top or
Bottom
Mains
Position

Both

Factory-Installed Main Circuit Breaker
30

CHOM1224M30GC

12

24

Included

Y

10,000 A

#6-2/0

6

50

CHOM1224M50GC

12

24

Included

Y

22,000 A

#6-2/0

6

Both

CHOM1224M60GC

12

24

Included

Y

22,000 A

#6-2/0

6

Both

CHOM1632M60GC

16

32

Included

Y

22,000 A

#6-2/0

7

Both

CHOM1224M70GC

12

24

Included

Y

22,000 A

#6-2/0

6

Both

CHOM1632M70GC

16

32

Included

Y

22,000 A

#6-2/0

7

Both

CHOM1224M100GC

12

24

Included

Y

22,000 A

#6-2/0

6

Both

CHOM1632M100GC

16

32

Included

Y

22,000 A

#6-2/0

7

Both

CHOM2448M100GC

24

48

Included

Y

22,000 A

#6-2/0

8

Both

CHOM3060M100GC

30

60

Included

Y

22,000 A

#6-2/0

10

Both

CHOM1224M125GC

12

24

Included

Y

22,000 A

#6-2/0

6

Both

CHOM1632M125GC

16

32

Included

Y

22,000 A

#6-2/0

8

Both

CHOM2448M125GC

24

48

Included

Y

22,000 A

#6-2/0

8

Both

CHOM3060M125GC

30

60

Included

Y

22,000 A

#6-2/0

10

Both

60
70

100

125

Factory-Installed Main Circuit Breaker
100

150

200

CHOM3060M2100GC

30

60

Included

Y

22,000 A

#4–250

10

Both

CHOM4284M2100GC

42

84

Included

Y

22,000 A

#4–250

12

Both

CHOM60120M2100GC

60

120

Included k

Y

22,000 A

#4–250

24

Both

CHOM2040M150GC

20

40

Included

Y

22,000 A

#4–250

9

Both

CHOM3060M150GC

30

60

Included

Y

22,000 A

#4–250

10

Both

CHOM60120M150GC

60

120

Included k

Y

22,000 A

#4–250

24

Both

CHOM2040M200GC

20

40

Included

Y

22,000 A

#4–250

9

Both

CHOM3060M200GC

30

60

Included

Y

22,000 A

#4–250

10

Both

CHOM4284M200GC

42

84

Included

Y

22,000 A

#4–250

12

Both

CHOM60120M200GC

60

120

Included k

Y

22,000 A

#4–250

24

Both

k Does not include a door. Order kit # CHOMDK602.
- Main Breaker loadcentres are approved for service entrance use. The main breaker compartment can be sealed and the main breaker can be locked.
- All type 1 loacentres are approved for vertical, horizontal, or inverted mounting.
- Canadian HomeLine loadcentres 8/16-space and above (double-row construction) come with Plug-on Neutral capability as standard.
08/16

DE1-25

DE1

Mains
Rating
in
Amps

LOAD CENTRES

Single-Phase, Three-Wire, 120/240 Vac Main Lugs – Indoor

Canadian HomeLine™ Circuit Breakers and Loadcentres
Type 3R Main Lug and Main Circuit Breaker Loadcentres

DE1

LOAD CENTRES

Single-Phase, Three-Wire, 120/240 Vac Main Lugs – Rainproof

Mains
Rating
in Amps

Loadcentre
Catalogue
Number

Maximum Number
of Circuits
Standard 1"

Tandem or
Quad

Loadcentre
Cover
Catalogue
Number

Service
Entrance
Approved

Maximum
Short
Circuit
Rating

Main
WireSize
AWG/kcmil
Al/Cu

Enclosure
No.
(Pages
34-35)

Top or
Bottom
Mains
Position

#12–3 Al
#14–4 Cu

1R

Top

Factory-Installed Main Lugs
70

CHOM24L70RB

2

4

Included

N

10,000 A

100

CHOM612L100RB

6

12

Included

N

10,000 A

#8–1

2R

Top

15R

Top

125

4

8

Included

N

10,000 A

#12–2/0 Al
#14–2/0 Cu

CHOM816L125GRB

8

16

Included

N

10,000 A

#6–2/0

3R

Top

CHOM1224L125GRB

12

24

Included

N

10,000 A

#6–2/0

3R

Top

CHOM48L125GRB

Factory-Installed Main Lugs
125

Single-Phase Three Wire 120/240 Vac Main Breaker – Rainproof
Factory-Installed Main Circuit Breaker
CHOM816M100GRB

8

16

Included

Y

22,000 A

#6-1

3R

Top

CHOM1224M100GRB

12

24

Included

Y

22,000 A

#6-2/0

3R

Top

40

Included

Y

22,000 A

#4–250

6R

Top

100

Factory-Installed Main Circuit Breaker
200

CHOM2040M200GRB

20

- Canadian HomeLine loadcentres 8/16-space and above (double-row construction) come with Plug-on Neutral capability as standard.

DE1-26

08/16

Canadian HomeLine™ Circuit Breakers and Loadcentres
Loadcentres
HomeLine Fusible Loadcentre Inserts (HFLCI)

DE1

HOMELINE

Fusible Loadcentre Inserts

Step #1

Step #2

Step #3

Step #4

Identify Box Dimensions and
Catalogue Number

Remove Old Fusible
Interior

Install New HFLCI

Complete Installation

•

HomeLine Fusible Loadcentre Inserts (HFLCI) offer the safety and reliability of a modern circuit breaker loadcentre system
featuring HomeLine circuit breakers.

•
•
•
•
•
•
•

Easily replaces outdated fusible loadcentres.
Eliminates drywall removal and repair.
Eliminates painting new drywall.
No holes to drill.
No new ground required.
No branch conductors or conduit to remove.
Using the HomeLine FLCI substantially reduces installation time, as much as 80%, allowing for the economical replacement of
old fusible loadcentres.

08/16

DE1-27

Canadian HomeLine™ Circuit Breakers and Loadcentres
Loadcentres
HomeLine Fusible Loadcentre Inserts (HFLCI)

DE1

LOAD CENTRES

READ THIS FIRST!
To select the proper HFLCI, follow these three steps:
Step 1: Find your fusible loadcentre catalogue number using columns 1 and 2.
Step 2: Confirm that the original fusible loadcentre box dimensions match those in columns 5, 6, and 7.
Step 3: Use column 3 to identify the HomeLine Fusible Loadcentre Insert (HFLCI) catalogue number.

CAUTION: Do not proceed with an installation unless both the existing catalogue number and box dimensions match.

1

2

3

4

5

Original
Manufacturer

Original Main
Lug Loadcentre
Catalogue
Number

HomeLine
Catalogue
Number**

Maximum Number
of Circuits

6

7

Box Dimensions
Height

Width

Depth

Standard 1"

Tandem
or Quad

Inches

mm

Inches

mm

Inches

mm

Amalgamated Electric

4208

HFLCI12D

6

12

16.126

410

8.506

216

2.813

72

Amalgamated Electric

4212

HFLCI16D

8

16

19.506

496

8.506

216

2.813

72

Amalgamated Electric

4220

HFLCI20AD

10

20

24.256

616

8.506

216

2.813

72

Amalgamated Electric

4220

HFLCI24AD

12

24

24.256

616

8.506

216

2.813

72

Amalgamated Electric

4216

HFLCI20BD

10

20

23.126

587

8.506

216

2.813

72

Amalgamated Electric

4216

HFLCI24BD

12

24

23.126

587

8.506

216

2.813

72

Amalgamated Electric

4312

HFLCI20BD

10

20

23.126

587

8.506

216

2.813

72

Amalgamated Electric

4312

HFLCI24BD

12

24

23.126

587

8.506

216

2.813

72

CEB

NHP10-634

HFLCIC16BD

8

16

20.126

511

7.876

200

3.063

78

CEB

NHP10-636-3

HFLCIC20BD

10

20

24.126

613

10.126

257

3.063

78

CEB

NHP10-636-3

HFLCIC20ED

10

20

27.876

708

10.251

261

3.063

78

CEB

NHP10-636-3

HFLCIC24BD

12

24

24.126

613

10.126

257

3.063

78

CEB

NHP12-60

HFLCIC12DD

6

12

20.126

511

7.876

200

3.063

78

CEB

NHP12-633

HFLCIC20AD

10

20

23.126

587

7.876

200

3.063

78

CEB

NHP12-633

HFLCIC24AD

12

24

23.126

587

7.876

200

3.063

78

CEB

NHP4-632

HFLCIC12BD

6

12

16.256

413

7.876

200

3.063

78

CEB

NHP4-632-1

HFLCIC16D

8

16

19.126

486

7.876

200

3.063

78

CEB

NHP4-633-1

HFLCIC16D

8

16

19.126

486

7.876

200

3.063

78

CEB

NHP6-60

HFLCIC12CD

6

12

13.876

353

7.876

200

3.063

78

CEB

NHP6-633-1

HFLCIC16BD

8

16

20.126

511

7.876

200

3.063

78

CEB

NHP6-636-4

HFLCIC16CD

8

16

24.126

613

7.876

200

3.063

78

CEB

NHP8-60

HFLCIC12D

6

12

16.256

413

7.876

200

3.063

78

CEB

NHP8-635-2

HFLCIC20AD

10

20

23.126

587

7.876

200

3.063

78

CEB

NHP8-635-2

HFLCIC24AD

12

24

23.126

587

7.876

200

3.063

78

Taylor (Crouse Hinds)

NHP0020

HFLCIT8AD

4

8

12.876

327

9.626

245

3.063

78

Taylor (Crouse Hinds)

NHP6-30-60

HFLCIT16AD

8

16

21.126

537

7.506

191

3.063

78

Taylor (Crouse Hinds)

NHP1231

HFLCIT20AD

10

20

24.626

626

9.626

245

3.063

78

Taylor (Crouse Hinds)

NHP20-0821-6

HFLCIT20AD

10

20

24.626

626

9.626

245

3.063

78

** HomeLine FLCI's include distribution section interior, trim, door and painted architectural white.
Note: Not suitable for use with Canadian HomeLine AFI, CAFI, DF or GFI devices.

DE1-28

08/16

Canadian HomeLine™ Circuit Breakers and Loadcentres
Accessories

RB Hub

LOAD CENTRES

Plug-in surge breaker
Ground bars
Neutral lugs
Filler plates
Type 3R rain hubs
Type 3R coupling trough

DE1

•
•
•
•
•
•
•
•
•
•

Door lock
Main lugs
Replacement covers
Replacement interiors

BC200 Enclosure Coupling

CHOM Surgebreaker®
Surge Arrester
2 spaces required.

PK6FL

PK15GTA

QOL125
LK100AN

HOMFP
QOM1FP

QOL225

QOM2FP

08/16

DE1-29

Canadian HomeLine™ Circuit Breakers and Loadcentres
HomeLine Loadcentre Accessories

Reference Loadcentre Catalogue
Number

DE1

LOAD CENTRES

Replacement Covers, 1 Phase, Type 1 Enclosures ONLY

Replacement
Cover
Catalogue
Number

CHOM24L70S *

4055800801

Surge Protective Device

Surge arrester for 1PH3W system
150Vac maximum phase-to-ground

CHOM24L70RB

4056314401

Interchangeable Hubs

CHOM24L70F *

4055800701

Conduit Size

CHOM48L125GC

4055844801

CHOM48L125GRB

4056318650

CHOM612L100S *

4055801702

CHOM612L100F *

4055801801

CHOM612L100RB

4056318550

CHOM816M100GRB

4056319050

CHOM1224M100GRB

4056319050

CHOM2040M200GRB

4056319150

CHOM 8-16,12-24 ML-MB loadcentres

CHOMC12UC

CHOM 16-32 60-100A MB loadcentres

CHOMC21UC

CHOM 16-32 125A, 24-48 ML-MB loadcentres

CHOMC24UC

CHOM 30-60 100-125A MB loadcentres

CHOMC30U125C

CHOM 30-60 150-225A ML-MB loadcentres

CHOMC30UC

CHOM 42-84 ML-MB loadcentres

CHOMC42UC

CHOM 20-40 MB loadcentres

CHOMC20UC

* No door on cover.

Catalogue Number
PK6FL

CHOM2175SB

Type B Hubs

Closing Plate
3/4"
1"
1 1/4"
1 1/2"
2"
2 1/2"

BCAP
B075
B100
B125
B150
B200
B250

B-150

Coupling Trough

Catalogue Number
Door Lock Kits, 1 Phase, Type 1 Enclosures ONLY

Catalogue
Number

Description

BC200

Description
BC200 - enclosure coupling for RB devices

Description
For use with type 1 Canadian
HomeLine Loadcentres.

Filler Plates

Description

Catalogue Number

Branch Breaker

HOMFP

QOM1 Main Breaker

QOM1FP

QOM2 Main Breaker

QOM2FP

Optional Neutral Lugs

Wire Size
#12-2 AL
#14-4 Cu

Catalogue Number
LK70AN

#6-2/0 AL/Cu

LK100AN

#14-2/0 AL/Cu

LK125AN

#2-3/0 Al/Cu

LK150AN

Main Lug Kits

Catalogue Number

DE1-30

Description

QOL125

125A Kit

QOL225

225A Kit

08/16

Canadian HomeLine™ Circuit Breakers and Loadcentres
Technical Information
TECHNICAL INFORMATION
Grounding Bar Kits
All PK equipment grounding bar kits are supplied
with mounting screws, necessary installation
Terminals

0.3125
[8]

Distance
Approximate
Between
Overall
Mounting Mounting
Length
Holes

Quantity Each Size
See “Wire Range
Table” below.

Catalogue Total
Number
Qty.
I

II

III

IV

V

VI

in

[mm]

in

[mm]
One
hole

Top

PK0GTA2

2

—

—

—

—

—

2

1.75

[44]

One
hole

PK0GTA6

6

—

—

—

—

6

—

4.61

[117]

1.69

[43]

Top

One
hole

Top

PK3GTA1

3

3

—

—

—

—

—

1.38

[35]

One
hole

PK4GTA

4

4

—

—

—

—

—

1.63

[41]

One
hole

One
hole

Top

PK5GTA

5

5

—

—

—

—

—

2.25

[57]

1.25

[32]

Top

PK7GTA

7

7

—

—

—

—

—

2.88

[73]

1.25

[32]

Top
or
Side

PK9GTA1

9

9

—

—

—

—

—

3.25

[83]

One
hole

One
hole

Top

D
s Section of Size 1 Ground

LOAD CENTRES

instructions and an “Equipment Grounding
Terminal” self-adhesive label.

DE1

n screw

PK9GTA

9

9

—

—

—

—

—

3.78

[96]

3.13

[80]

Top

PK12GTA

12

12

—

—

—

—

—

4.70

[119]

3.13

[80]

Top

PK15GTA

15

15

—

—

—

—

—

5.63

[143]

3.13

[80]

Top

PK15GTAL

16

15

1

—

—

—

—

8.13

[207]

3.13

[80]

Top

PK15GTA6 1

21

15

—

—

6

—

—

5.88

[149]

✒

2

Top

PK18GTA

18

18

—

—

—

—

—

6.56

[167]

3.13

[80]

Top

PK18GTAL

19

18

1

—

—

—

—

8.81

[224]

3.13

[80]

Top

PK23GTA

23

23

—

—

—

—

—

8.11

[206]

3.13

[80]

Top

PK23GTAL

24

23

1

—

—

—

—

9.44

[240]

3.13

[80]

Top

PK27GTA 3

27
or
26

27
or
26

—

1

—

—

—

9.36

[238]

3.13

[80]

Top

1

Mounting screws 21594-14241(two required) and 21594-17121(two required).

2

3.13 in. (80 mm) on small terminals; 5.25 in. (133 mm) on large terminals.

3

PK27GTA includes one main grounding lug that mounts with two terminal screws and requires
three terminals for mounting.

Wire Range Table

08/16

Size

Cu (AWG)

Al (AWG)

I

(1) #14–#4 or (2) #14 or #12

(1) #12–#4 or (2) #12 or #10

II

(1) #1–4/0

(1) #1–4/0

III

(1) #6–2/0

(1) #6–2/0

IV

(1) #6–3/0

(1) #6–3/0

V

(1) #14–1/0

(1) #14–1/0

VI

(1) #10–2/0

(1) #6–2/0

DE1-31

Canadian HomeLine™ Circuit Breakers and Loadcentres
Wiring Diagrams

LOAD CENTRES

WIRING DIAGRAMS

S
N

S/N

S
N

DE1

S
N

CHOM24L70S/F

CHOM612L100S/F

CHOM816L125GC

CHOM24L70RB

CHOM612L100RB

CHOM816L125GRB

S
N

S
N

S
N

S
N

CHOM1224L125GC
CHOM1632L125GC

CHOM1224L125GRB

S
N

S
N
S
N

S
N

S
N

CHOM2448L125GC

DE1-32

S
N

CHOM3060L225GC

CHOM4284L225GC

08/16

Canadian HomeLine™ Circuit Breakers and Loadcentres
Wiring Diagrams

S
N

MAIN

MAIN

S
N

S
N

CHOM816M100RB

LOAD CENTRES

S
N

DE1

CHOM1224M100GC
CHOM1224M125GC
CHOM1224M100GR

S
N
S
N

MAIN

CHOM1632M100GC
CHOM1632M125GC

S
N

MAIN

MAIN

S
N

S
N

MAIN

S
N

S
N

S
N

CHOM2040M150GC
CHOM2040M200GC
CHOM2040M200GRB

S
N

MAIN

S
N

CHOM3060M100GC
CHOM3060M125GC
CHOM3060M150GC
CHOM3060M200GC
CHOM3060M2100GC

CHOM2448M100GC
CHOM2448M125GC

S
N

MAIN

S
N

CHOM4284M200GC
CHOM4284M2100GC

CHOM60120M200GC

1-Phase, 3-Wire Main Circuit Breakers

08/16

DE1-33

Canadian HomeLine™ Circuit Breakers and Loadcentres
Wiring
Indoor Diagrams
Dimensions and Knockouts
INDOOR DIMENSIONS AND KNOCKOUTS

DE1

LOAD CENTRES

Indoor Dimensions
W

Box
No.

H

D

in.

mm

in.

mm

in.

mm

2

4.81

122

9.30

236

3.19

81

4

8.88

226

12.57

319

3.80

97

6

14.25

362

17.92

455

3.75

95

7

14.25

362

20.92

531

3.75

95

8

14.25

362

26.04

661

3.75

95

9

14.25

362

29.86

758

3.75

95

10

14.25

362

33.78

858

3.75

95

12

14.25

362

39.37

1000

3.75

95

21

8.88

226

14.80

376

3.80

97

24*

14.25

362

48.50

1232

3.75

95

Knockouts
Symbol

A

B

C

D

E

F

G

H

I

Conduit
Size

0.50 in.
13 mm

0.75 in.
19 mm

1.00 in.
25 mm

1.25 in.
32 mm

1.50 in.
38 mm

2.00 in.
51 mm

2.50 in.
64 mm

3.00 in.
76 mm

3.50 in.
89 mm
B, C, D, E

* Note: Box 24 knockout drawing to follow.
B, C,
D, E

A, B, C, D
A, B, C

A, B,
C A

A,
B A B, C, D, E
B, C, D, E

C, D, E,
F,G A

A, B
B, C, D, E

C, D, E, F

A, B

A

A
A
B, C,
D, E

B, C, D, E
B, C, D, E

B, C, D,E
B, C, D, E

C, D, E,
F,G
A

A, B, C, D

Box 4

Box 2

C, D, E,
F,G
A

Box 7

A, B

C, D, E, F
A, B

C, D, E,
A A, B
B, C, D, E F,G
B, C, D, E
C, D, E, F
D, E,
D, E, F, G
F, G
B, C

B, C, D, E

C, D, E, F

A, B
A, B
A
A

A, B, C, D

B, C, D, E

Box 8

Box 6

B, C, D, E
C, D, E, F
D, E, F, G

D, E,
F, G

A, B, C, D

C, D, E,
F,G
A A, B
B, C, D, E
D, E, F, G

B, C, D, E
B, C, D, E
D, E, F, G

A, B, C, D
C, D, E, F

Box 9

C, D, E,
F, G
A A, B
C, D, E, F
D, E, F, G

B, C

B, C
A, B

A, B

A

A

A, B A B, C, D, E
B, C, D, E
B, C, D, E

A

D, E,
F, G

DE1-34

A, B, C, D,
C, D, E, F

Box 10

A, B, C, D
B, C, D, E

C, D, E, F

Box 12

B, C, D, E

B, C, D, E

B, C, D, E

Box 21

08/16

Canadian HomeLine™ Circuit Breakers and Loadcentres
Outdoor Dimensions and Knockouts
OUTDOOR DIMENSIONS AND KNOCKOUTS

W

H

LOAD CENTRES

Outdoor Dimensions
D

1

in.

mm

in.

mm

in.

mm

1R1

4.88

124

9.38

238

4.00

102

2R

8.88

226

12.65

321

4.27

108

3R

14.75

375

18.92

481

4.52

115

6R

14.75

375

29.86

758

4.52

115

15R

8.88

226

14.80

376

4.27

108

DE1

Box No.

CHOME250SPA top endwall has no hub opening.

Knockouts
Symbol
Conduit
Size

A

B

C

D

E

F

G

H

0.50 in. 0.75 in. 1.00 in. 1.25 in. 1.50 in. 2.00 in. 2.50 in. 3.00 in.
13 mm 19 mm 25 mm 32 mm 38 mm 51 mm 64 mm 76 mm

2.5 in. (64 mm)
Hub Max.
2.5 in. (64 mm)
Hub Max.

2.5 in. (64 mm)
Hub Max.

A, B, C, D

C, D, E F, G

C, D,
C, D, E, F
E, F A A, C, D, A, B, C
B E, F,
G

B, C,
A
D, E
A,
B
B, C, D, E

B, C, D, E

A
A, B
Box 1R

Box 3R

Box 2R

2.5 in. (64 mm)
Hub Max.

2.5 in. (64 mm)
Hub Max.
C, D, E, F, G

C, D,
E, F A

C, D, E, F
A, B C, D,A, B, C
E, F, G
Box 6R

B, C, D, E

B, C, D, E
A
A, B
B, C, D, E
Box 15R

E.&O.E.

08/16

DE1-35

DE1

LOAD CENTRES

Intentionally left blank

DE1-36

08/16

Stab-lok Circuit Breakers
General Information
Features and Benefits

•

Type NC with Robertson/slot screws

•

Type NC with colour coded handles

•

Thermal magnetic trip protection
Exclusive line side stab connection

•

Trip free operation

•

Calibrated at 40° C

•

Availability of a wide range of GFCIs

•

Arc resistant case

NC The Compact Stab-lok Breaker 1/2” Wide per pole

DE1

•

Stab-lok Breaker Rating Table
Type
NC

NA

Poles
1
2
1
2
3

1C

2

2C

2

NC015, NC0215, NC0230

Amp
Rating

Maximum
Voltage

Interrupting
Capacity

15-50
15-50
15-50
15-150
15-100
30-40
50-125
100-200

120
120/240
120
120/240
240

10,000 A
10,000 A
10,000 A
10,000 A
10,000 A
10,000 A
22,000 A
22,000 A

120/240
120/240

NA The Original Stab-lok Breaker - 1” Wide per pole

NA15

NA3P20

08/16

LOAD CENTRES

Breaker Features:

NA215

NA2P100

DE1-37

Stab-lok Circuit Breakers
Circuit Breakers and Accessories
Standard and Main Circuit Breakers

Type

Amp
Rating

1 Pole Cat.
No.

NC

15
20
25
30
40
50

NC015
NC020
NC025
NC030
NC040
NC050

15

NA15(2)

NA215

NA3P15

20

NA20(2)
NA25
NA30
NA35
NA40
NA50
—
—
—
—
—

NA220

NA3P20

NA225
NA230
—
NA240
NA250
NA260
NA270
NA2P90
NA2P100
NA2P125

—
NA3P30
—
NA3P40
NA3P50
NA3P60
NA3P70
NA3P90
NA3P100
—

—

—

—

DE1

LOAD CENTRES

Standard Loadcentre Breakers

NA

25
30
35
40
50
60
70
90
100
125
150

—

List
Price

Lug Range

2 Pole Cat.
No.
NC0215
NC0220
NC0225
NC0230
NC0240
NC0250

#14 - #6

#14 - #4

#14 - #2

—
—
—
—
—

—

—

List
Price

NA2P150

Lug Range

#14 - #6

#14 - #4

—

#14 - #2

#4 - 2/0

1

3 Pole Cat.
No.

List
Price

Lug Range

—
—
—
—
—
—

—
—
—
—
—
—

—

—
—
#14 - 1/0

Notes:
1. NA2P150 rated 150A when used with copper conductor only
2. Switching duty approved breakers. Breakers are marked SWD
3. 2-pole and 3-pole breakers greater than 70A take 4 and 6 NA breaker
positions respectively
4. Use solid conductor only when #14 wire is used
5. *

Stab-lok Main Circuit Breakers
Type
NA

1C

2C

Amp
Rating

2 Pole Cat
No.

30-100
30
40
50
60
70
90
100
125
100
125
150
175
200

—
1C30
1C40
1C50
1C60
1C70
1C90
1C100
1C125
2C100
2C125
2C150
2C175
2C200

List Price

Lug Range

—

—

#4-2/0

#4-250MCM

3 Pole Cat
No.
—
—
—
—
—
—
—
—
—
—
—
—
—

List Price

Lug
Range

Use Breaker Table Above
—
—
—
—
—
—
—
—
—
—
—
—
—

—
—
—
—
—
—
—
—
—
—
—
—
—

2C200

* NC015/NC0215 Breaker Handle Colour - Blue
NC020/NC0220 Breaker Handle Colour - Red
NC030/NC0230 Breaker Handle Colour - Green
NC040/NC0240 Breaker Handle Colour - Grey

DE1-38

08/16

Stab-lok Circuit Breakers

Breaker Type

Handle Lock Off NonPadlocking

Poles

Amp Rating

1

15 - 50

NCLOK(3) / 1LOK(2)

2

15 - 50

—

1

15 - 50

1LOK

2

15 - 70

—

—

2
3
3

90 - 150
Non - Modular
Modular

—
—
—

—
—
—

Cat. No.
NC

NA

List Price

—

Handle Lock Off
Padlocking

Handle Tie

Cat. No.

List Price

Cat. No.

—

—

NCTIE(1) / HTNC(2)

CLOK
(Not suitable for
ribbed handles)

—

1LOB

HTNA
(Not to be used for 2
pole applications)

2LOK
(2+3 pole
modular)
CLOK
3100LOK
2LOK

List Price

—

—

—

—
—
—

—
—
—

Note: Standard Packaging Size for all breaker accessories is 10
1. Suitable for ribbed handled NC breakers.
2. Suitable for square handled NC breakers.
3. Suitable for ribbed handled NC 1 + 2 pole breakers.

08/16

DE1-39

DE1

Stab-lok Breaker Accessories

LOAD CENTRES

Stab-lok Breaker Accessories

Stab-lok Circuit Breakers

DE1

LOAD CENTRES

Ground Fault Circuit Breakers and Spa Pack

Circuit Breakers
Stab-lok GFI with 5 mA Sensitivity (Class A)
Type

Amp
Rating

1 Pole
Cat. No.

NA

15
20
30
40

NAGF15
NAGF20
NAGF30
NAGF40

List
Price

2 Pole
Cat. No.

List
Price

NAGF215
NAGF220
NAGF230
NAGF240

NAGF15

NAGF215

Stab-lok GFI with 33 mA Sensitivity
Type

Amp
Rating

1 Pole Cat.
No.

NA

15
20
30
40

NAGF1533
NAGF2033
NAGF3033
NAGF4033

List
Price

2 Pole Cat.
No.

List
Price

NAGF21533
NAGF22033
NAGF23033
NAGF24033

Notes:
1. Submersible pump installations require ground fault protection to the
maximum sensitivity level of 10mA. These breakers are designed to
meet the Canadian Electrical Code under rule CEC 26-956

Stab-lok GFI with 10mA Sensitivity
Type

Amp Rating

2 Pole Cat. No.

NA

15
20
30
40

NAGF21510
NAGF22010
NAGF23010
NAGF24010

List Price

2. GFI breakers maximum 250 feet (one way) feeder length
3. Use solid conductor only when #14 wire is used
4. GFI 15 Amp Handles - Blue, GFI 20 Amp Handles - Red,
GFI 30 Amp Handles - Green, GFI 40 Amp Handles - Grey

DE1-40

08/16

Stab-lok Circuit Breakers

As per the Canadian Electrical Code (CEC), AFCIs will be required for ALL bedroom receptacle circuits beginning January 2002. The CEC does not
mandate existing homes be upgraded with AFCIs. However, if a new bedroom is added, the AFCI will be required. Reduce the risk of fire with the
installation of Federal Pioneer arc-fault circuit interrupters.

Ampere Rating

Poles
120Vac

Catalogue Number

15

1

NA15AFI

20

1

NA20AFI

DE1

Stab-lok - AFCI Stab-lok Arc Fault Circuit Interrupters (10,000 AIR)

Arc faults are any abnormal flow of electricity that create an arc, spark or
flash which is hot and capable of igniting flammable materials, thereby
increasing the potential for a residential fire.

Arcing can occur and may lead to fires in these common conditions:
•
•
•
•

pierced insulation on electrical construction wire
frayed appliance extension cords
loose electrical connections
overheated electrical cords and wires

The Federal Pioneer AFCI utilizes state-of-the-art digital microprocessor
technology that has been coupled with a Stab-lok circuit breaker. These
devices will disconnect power to the circuit during any of these conditions:
•
•
•

short circuit
overload
arc faults - parallel, line-to-neutral or line-to-ground, or in series on a
damaged wire

Federal Pioneer AFCI can be installed in any new or existing Stab-lok
load centre.
* NA15AFI Breaker Handle Colour - Blue
NA20AFI Breaker Handle Colour - Red

Stab-lok Generator Panel - Replacement Breakers
Catalogue
Number

Amp
Rating

Main Breaker Type

NA3P30GEN
NA3P60GEN
NA3P70GEN

30
60
70

NA3P30 Amp Modular Breaker-Transfer Disconnect
NA3P60 Amp Modular Breaker-Transfer Disconnect
NA3P70 Amp Modular Breaker-Transfer Disconnect

08/16

LOAD CENTRES

Arc-Fault Circuit Interrupters and Stab-lok Generator Panel - Replacement Breakers

List Price

DE1-41

Stab-lok Circuit Breakers

Receptacle Kits
Description

Cat. No.

Receptacle Kits for RH102-4CHTS
One 15A 125V duplex with break-off tabs for separate feed. (Eagle #4270B)

K1

One 30A 125V (Eagle #1263)

K3

Side blanking plate for RH102-4CHTS units.

RH1024CHTSBRC

DE1

LOAD CENTRES

Recreation Vehicle Park Power Centre - Receptacle Kits

Receptacle Kits for RH104-8CHTS
One 15A 125V duplex with break-off tabs for separate feed. (Eagle #4270B)

RM15

Two 15A 125V duplex with break-off tabs for (Eagle #4270B)

RM1515

15A receptacle module kit 1-1 GFI
15A (Hubbell GFR5252)

RM15GFI

15A receptacle module kit 2-1 GFI
15A (Hubbell GFR5252)

RM1515GFI

20A receptacle module kit 2-1 GFI
20A (Leviton 8899)

RM2020GFIS

One 30A 125V (Eagle #1263)

RM30

One 50A 125/250V (Eagle #58)

RM50

One 30A 125V and one 15A 125V duplex with break-off tabs for separate
feed (Eagle #1263 & #4270B)

RM1530

One 30A 125V and one 15A GFI receptacle (Hubbell GFR5252)

RM15GFI30

One 125V twist lock 20A (Hubbell #23CM10) 30A (Hubbell #26CM10)

RM20TL
RM30TL

Side blanking plate for RH104-8CHTS using non-twist lock receptacle kits.
Side blanking plate for RH104-8CHTS using twist lock receptacle kits.

RM00
RMBLTL

DE1-42

08/16

Stab-lok Loadcentres and Circuit Breakers
Accessories
Stab-lok Loadcentre Accessories

Door Kit
Catalogue
Number

108-16-125

DK1W98

112-24-125

DK2W98

116-32-125

DK3W98

120-40-125

DK4W98

124-48-125

DK5W98

132-64-225

DK8W98

142-84-225

DK9W98

BE108-16-1CXXX

DK1BEW98

BE112-24-1CXXX

DK2BEW98

BE116-32-1CXXX

DK3BEW98

BE120-40-1CXXX

DK4BEW98

BE124-48-1CXXX

DK5BEW98

BE132-64-1CXXX

DK6BEW98

BE120-40-2CXXX

DK7BEW98

BE124-48-2CXXX

DK7BEW98

BE132-64-2CXXX

DK8BEW98

BE142-84-2CXXX

DK9BEW98

List Price

Std. Package
Size

DE1

Reference Loadcentre
Catalogue Number

LOAD CENTRES

Door Kits, 1 Phase, Type 1 Enclosures ONLY

3

PK6FL

DK3W98

Main Lug Kits

Note: For use with W98 Series Stab-lok loadcentres.

Max. Bus Rating (A)

Main Lug Kit Catalogue
Number

125A

QOL125

225A

QOL225

Door Lock Kits, 1 Phase, Type 1 Enclosures ONLY
Catalogue Number
PK6FL

List Price

List Price

Description
For use with 125 and 225A W98
Series Stab-lok loadcentres.

Note: For use with W98 Series Stab-lok loadcentre interior. Single phase
only.

Filler Plates
Catalogue
Number

PF1

BFAB

Filler plate for NA or NC breakers. For use in
present design of Stab-lok enclosures, except
400 A - see BFAB. Will also fit previous design
using 1/2” metal KO’s PF1 consists of 1 strip of 4
1/2” plastic fillers suitable for 4 NC poles or 2 NA
poles.
Minimum order quantity 25
Filler plate for 1 NA breaker. For use in present
400 A enclosure design and previous enclosure
designs using aluminum center strip.
Minimum order quantity: 50

PF1

04/16

List
Price

Description

BFAB

DE1-43

Stab-lok Circuit Breakers

DE1

LOAD CENTRES

Stab-lok Loadcentre Accessories

Sub-Feed Kits, MLO Panels Only
Enclosure
Cat.
No.
10816125
11224125
11632125
12040125
12448125
31224 S/F
31836 S/F
33060 S/F
34284225 S/F

Ordering
Catalogue
Number

Drip Proof Hoods EEMAC 2

List
Price

Amp
Rating
(A)

Lug Range

SFL125W98*

125 A

#6-300MCM

SFL100

100 A

#14-1/0

SFL225

225 A

#6-300MCM

Enclosure Cat.
No.
1022S
1024S
1048S
31224S
31836S
33060S
34284225S

Ordering
Catalogue
Number

Std. Package
Size

R2

4

R4

2

SDH

1

List Price

* For use with 125A W98 Series Stab-lok Loadcentres.
** Sub-feed lugs for 225A W98 Series may be ordered as a factory installed option.

SFL100

Touch Up Paint
Description

Ordering
Catalogue Number

Architectural White

ARCWHITE

List Price

GLK12

Ground Lug Kits
No. of Ccts

Ordering
Catalogue
Number

3
6
10
12

L79A253
GLK6
GLK10
GLK12

List
Price

Lug Range

#14 - #4

Neutral Lug Kits
Amp Rating

Ordering
Catalogue
Number

150

NLK150W98

List Price

Lug Size
#6 - 2/0

Note: Suitable for Cu/Al conductors.

DE1-44

08/16



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
Author                          : 
Create Date                     : 2016:10:22 15:20:36+05:30
Modify Date                     : 2016:10:22 15:20:36+05:30
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Producer                        : Acrobat Distiller 11.0 (Windows)
Creator Tool                    : FrameMaker 10.0.2
Metadata Date                   : 2016:08:14 17:55:32-04:00
Format                          : application/pdf
Title                           : untitled
Creator                         : 
Document ID                     : uuid:524e1b85-0cda-45ca-9306-cbd439293aa3
Instance ID                     : uuid:c69d414f-9471-4561-a9bf-e17ab84a3859
Page Count                      : 44
EXIF Metadata provided by EXIF.tools

Navigation menu