R Contactor.indb Brochure
2016-10-27
: Pdf 1000449036-Brochure 1000449036-Brochure B6 unilog
Open the PDF directly: View PDF .
Page Count: 137
Download | |
Open PDF In Browser | View PDF |
US catalog R contactors Control of AC and DC power circuits up to 5000 A Motor rated operational powers and currents The currents given below concern standard three-phase four-pole cage motors (1500 r.p.m. at 50 Hz 1800 r.p.m. at 60 Hz). These values are given for guidance and may vary according to the motor manufacturer and depending on the number of poles. IEC Motor nominal current: standardized values in blue color (according to IEC 60947-4-1 Annex G) UL / CSA Motor nominal current: standardized values (according to IEC 60947-4-1 Annex G and UL 508) Motor power 220 V 230 V 240 V 380 V 400 V 415 V 440 V 500 V 660 V 690 V Motor power 208 V 220-240 V 380-415 V 440-480 V kW A A A A A A A A A A hp A A A A A 0.06 0.09 0.12 0.18 0.25 0.37 0.55 0.75 1.1 1.5 2.2 3 4 5.5 7.5 11 15 18.5 22 30 37 45 55 75 90 110 132 160 200 250 315 355 400 500 560 630 710 800 900 1000 0.37 0.54 0.73 1 1.6 2.0 2.7 3.5 4.9 6.6 8.9 11.8 15.7 20.9 28.2 39.7 53.3 63.8 75.3 100 120 146 177 240 291 355 418 509 637 782 983 1109 1255 1545 1727 1928 2164 2446 2760 3042 0.35 0.52 0.7 1 1.5 1.9 2.6 3.3 4.7 6.3 8.5 11.3 15 20 27 38 51 61 72 96 115 140 169 230 278 340 400 487 609 748 940 1061 1200 1478 1652 1844 2070 2340 2640 2910 0.34 0.50 0.67 1 1.4 1.8 2.5 3.2 4.5 6 8.1 10.8 14.4 19.2 25.9 36.4 48.9 58.5 69 92 110 134 162 220 266 326 383 467 584 717 901 1017 1150 1416 1583 1767 1984 2243 2530 2789 0.21 0.32 0.46 0.63 0.9 1.2 1.6 2.0 2.8 3.8 5.2 6.8 8.9 12.1 16.3 23.2 30.5 36.8 43.2 57.9 69 84 102 139 168 205 242 295 368 453 568 642 726 895 1000 1116 1253 1417 1598 1761 0.2 0.3 0.44 0.6 0.85 1.1 1.5 1.9 2.7 3.6 4.9 6.5 8.5 11.5 15.5 22 29 35 41 55 66 80 97 132 160 195 230 280 350 430 540 610 690 850 950 1060 1190 1346 1518 1673 0.19 0.29 0.42 0.58 0.82 1.1 1.4 1.8 2.6 3.5 4.7 6.3 8.2 11.1 14.9 21.2 28 33.7 39.5 53 64 77 93 127 154 188 222 270 337 414 520 588 665 819 916 1022 1147 1297 1463 1613 0.18 0.26 0.39 0.53 0.74 1 1.3 1.7 2.4 3.2 4.3 5.7 7.4 10.1 13.6 19.3 25.4 30.7 35.9 48.2 58 70 85 116 140 171 202 245 307 377 473 535 605 745 832 929 1043 1179 1330 1466 0.16 0.24 0.32 0.48 0.68 0.88 1.2 1.5 2.2 2.9 3.9 5.2 6.8 9.2 12.4 17.6 23 28 33 44 53 64 78 106 128 156 184 224 280 344 432 488 552 680 760 848 952 1076 1214 1339 0.13 0.18 0.24 0.37 0.51 0.67 0.91 1.15 1.7 2.2 2.9 4 5.1 7 9.3 13.4 17.8 22 25.1 33.5 40.8 49.1 59.6 81 97 118 140 169 212 261 327 370 418 515 576 643 721 815 920 1014 0.12 0.17 0.23 0.35 0.49 0.64 0.87 1.1 1.6 2.1 2.8 3.8 4.9 6.7 8.9 12.8 17 21 24 32 39 47 57 77 93 113 134 162 203 250 313 354 400 493 551 615 690 780 880 970 1/2 3/4 1 1-1/2 2 3 5 7-1/2 10 15 20 25 30 40 50 60 75 100 125 150 200 250 300 350 400 450 500 2.4 3.5 4.6 6.6 7.5 10.6 16.7 24.2 30.8 46.2 59.4 74.8 88 114 143 169 211 273 343 396 528 – – – – – – 2.2 3.2 4.2 6 6.8 9.6 15.2 22 28 42 54 68 80 104 130 154 192 248 312 360 480 604 722 828 954 1030 1180 1.3 1.8 2.3 3.3 4.3 6.1 9.7 14 18 27 34 44 51 66 83 103 128 165 208 240 320 403 482 560 636 – 786 1.1 1.6 2.1 3 3.4 4.8 7.6 11 14 21 27 34 40 52 65 77 96 124 156 180 240 302 361 414 477 515 590 0.9 1.3 1.7 2.4 2.7 3.9 6.1 9 11 17 22 27 32 41 52 62 77 99 125 144 192 242 289 336 382 412 472 2 1SXU10607C0201 | R contactor US catalog 550-600 V R contactors Control of AC and DC power circuits up to 5000 A 1 Overview 2 Construction characteristics 3 AC circuit switching 4 DC circuit switching 5 Advanced applications 6 General technical data 7 Accessories and spare parts 8 Terminal marking and wiring diagrams 9 Dimensions 10 Terms and definitions 11 Questionnaire 12 Index R contactor US catalog | 1SXU106047C0201 3 R contactors Engineered to perform in heavy duty applications With over 100 years of experience in control, ABB meets AC and DC requirements from 63 A up to 5000 A with R contactor range. We offer our application know-how through the R contactor range to perfectly match your utilization requirements, whatever the usage condition and the required configuration. Robustness and reliability bring R contactors technology beyond the limits of other contactors. Secure Operation Reliability ¡ ¡ ¡ ¡ High making and breaking capacity Durability up to 5 million electrical operations Easy inspection access and availability of spare parts Experienced and proven for years Improved Installation Efficiency ¡ ¡ ¡ ¡ Variable number of poles NO, NC or combined main poles configuration Main pole for On-load breaking or for coupling Magnetic or mechanical latch available Increased Application Productivity ¡ Rated current up to 5000 A ¡ Rated voltage up to 1000 V AC or 1500 V DC ¡ IEC AC-1, AC-3, DC-1, DC-3 and DC-5 utilization categories. ¡ UL general use rated 800 - 2000A at 600VDC ¡ Mechanical switching frequency up to 1200 cycles per hour ... you can trust From standard to tailor-made solution – Most commonly used configurations are presented in the R contactor catalog and well documented – 120V 60Hz coil and 2 N.O. + 2 N.C. auxiliary contacts as standard – Other configurations and ratings are available on request Engineered to perform in wide variety of applications Industries – Iron and steel industries – Mining – Cranes – Induction furnaces 4 Power generation – Hydroelectric power stations – Photovoltaic power plants – Power distribution – Energy storage 1SXU10607C0201 | R contactor US catalog Infrastructure – Power panels – Pump station – Rail transportation R contactors Get the right product Conventional applications 1 AC circuit switching DC circuit switching Up to 500 V AC IOR contactors Up to 1500 V DC with poles in series IOR..CC contactors From 500 up to 1000 V AC IOR..MT contactors AC-1 Rated operational current up to 5000 A AC-3 Rated power up to 1500 kW (1520 A - 440 V) DC-1 Rated operational current up to 5000 A DC-3 / DC-5 operational current up to 2000 A Advanced applications N.O./N.C. main poles combination Power circuit coupling Slip-ring motor control AC circuit switching NOR..MT contactors Up to 1000 V AC / 1500 V DC LOR couplers Ue up to 5000 V AC FOR contactors DC circuit switching NOR..CC contactors Energy saving and safety requirements Alternator field discharge Equipped with latching ..AMA, ..AME contactor types Umax 2250 V DC AM-CC-JORE contactors R contactor US catalog | 1SXU106047C0201 5 R contactors for AC circuit switching 1 Rated operational voltage Ue from 500 up to 1000 V AC Contactor type IORR63..MT Categories AC-1 IORR125..MT IORR200..MT IORR400..MT IORR500..MT IORR800..MT Ue at 40 °C AC-3 AC-3 Ie 85 A 170 A 260 A 400 A 550 A 800 A 690 V AC Ie 85 A 160 A 260 A 400 A 550 A 800 A 1000 V AC max. Ie 56 A 105 A 180 A 280 A 380 A 580 A 150 kW 240 kW 400 kW 540 kW 780 kW 690 V AC Power 80 kW *120 V 60Hz coil and 2 N.O. + 2 N.C. auxiliary contacts as standard Rated operational voltage Ue up to 500 V AC Contactor type – Categories AC-1 AC-3 AC-3 Ue at 40 °C Ie From 85 A to 550 A, select above IOR..-MT 900 A 380-415-440 V AC Ie – 800 A 500 V AC max. Ie – 800 A Power – 450 kW 400 V AC *120 V 60Hz coil and 2 N.O. + 2 N.C. auxiliary contacts as standard 6 IORR800 1SXU10607C0201 | R contactor US catalog 1 IORR1400..MT IORR1700..MT IORR2100..MT IORR2500..MT IORR3200..MT IORR3800..MT IORR4500..MT IORR5100..MT 1250 A 1650 A 1850 A 2200 A 3000 A 3500 A 4000 A 4500 A 970 A 1170 A 1270 A – – – – – 610 A 680 A 810 A – – – – – 1000 kW 1200 kW 1300 kW – – – – – IORR1000 IORR1400 IORR1700 IORR2100 IORR2500 IORR3200 IORR3800 IORR4500 IORR5100 1000 A 1350 A 1650 A 2000 A 2400 A 3200 A 3800 A 4500 A 5000 A 800 A 1080 A 1260 A 1520 A – – – – – 800 A 1080 A 1220 A 1340 A – – – – – 450 kW 630 kW 750 kW 900 kW – – – – – R contactor US catalog | 1SXU106047C0201 7 R contactors for DC circuit switching 1 Rated operational voltage Ue up to 1500 V DC Contactor type Number of poles Categories in series IORR63 ..CC IORR125 ..CC IORR200 ..CC IORR400 ..CC IORR500 ..CC Ue max. DC-1 500 V DC Ie 85 A 170 A 275 A 400 A 550 A DC-3 / DC-5 500 V DC Ie 68 A 125 A 205 A 350 A 500 A DC-1 1000 V DC Ie 85 A 170 A 275 A 400 A* 550 A* DC-3 / DC-5 1000 V DC Ie 68 A 125 A 205 A 350 A 500 A DC-1 1500 V DC Ie 85 A* 170 A* 275 A* 400 A* 550 A* DC-3 / DC-5 1500 V DC Ie 68 A* 125 A* 205 A* 350 A* 500 A* 1 pole 2 poles 3 poles * Ue max. = 1500 V DC, version with increased insulation for 1000 V DC < Ue ≤ 1500 V DC, please consult us. *120 V 60Hz coil and 2 N.O. + 2 N.C. auxiliary contacts as standard Contactors UL / CSA approved Rated operational voltage Ue up to 600 V DC Contactor type IORR800-10-CC-U IORR1000-10-CC-U IORR1400-10-CC-U IORR1700-10-CC-U IORR2100-10-CC-U 1000 A 1700 A 2000 A U max. 1 pole General use 600 V DC Ie 800 A *120 V 60Hz coil and 2 N.O. + 2 N.C. auxiliary contacts as standard 8 1SXU10607C0201 | R contactor US catalog 1300 A 1 IORR800..CC IORR1000..CC IORR1400..CC IORR1700..CC IORR2100..CC IORR2500..CC IORR3200..CC IORR3800..CC IORR4500..CC IORR5100..CC 750 V DC 800 A 1000 A 1250 A 1600 A 2000 A 2300 A 3200 A 3800 A 4500 A 5000 A 600 V DC 720 A 1000 A 1250 A 1600 A 2000 A On request On request On request On request On request 1500 V DC 800 A 1000 A 1250 A 1600 A 2000 A 2300 A 3200 A 3800 A 4500 A 5000 A 1000 V DC 720 A 1000 A 1250 A 1600 A 2000 A On request On request On request On request On request 1500 V DC 800 A 1000 A 1250 A 1600 A 2000 A 2300 A 3200 A 3800 A 4500 A 5000 A 1500 V DC 720 A 1000 A 1250 A 1600 A 2000 A On request On request On request On request On request Ue max. R contactor US catalog | 1SXU106047C0201 9 2 10 1SXU10607C0201 | R contactor US catalog Construction characteristics Construction characteristics 12 Contactors with magnetic latching ..AMA type 14 Contactors with mechanical latching ..AME type 15 Type and order code for R contactors 16 Coil voltage and blowout type 17 2 Auxiliary contacts Main characteristics R contactor US catalog | 1SXU106047C0201 18 11 Construction characteristics Auxiliary frame Auxiliary contacts Upper connection This design offers a great flexibility with standard types as well as special variants 2 Flexible design R contactors are built with a main frame supporting main poles, electro-magnet, auxiliary contacts and feature: – Variable number of N.O. and N.C. poles, with or without blowout coils – Large number of N.O. and N.C. auxiliary contacts – Control circuit for standard and specific voltages – Mechanical or magnetic latching available. Main frame Electro-magnet Lower connection Main poles with arc chutes All parts are easily accessible and removable from the front. Main frame The main frame is designed with a fixed bar and a rotating shaft linked by 2 bearings. All parts (poles, electro-magnet, auxiliary contacts) are mounted on this frame. Small frame for R63 ... R500 contactors Large frame for R800 ... R5100 contactors Fixed bar Auxiliary frame Rotating shaft Bearings Main poles Arc chute Arcing horn Fixed contacts Moving contacts The moving contacts are similarly mounted and move directly with the rotating shaft. A blowout coil The standard blowout coil is rated to carry the total current flowing through the poles. Arc chutes Ensure a rapid extinction of the arcs. Quick and easy removal of the arc chutes allows an easy inspection of the contacts and their replacement if necessary. Each pole is designed with: Fixed and moving contacts The fixed contacts are mounted on an insulated support screwed onto the fixed bar. 12 1SXU10607C0201 | R contactor US catalog Arcing horn Assits the elongation and breaking of the electric arc (not applicable to LOR couplers). Construction characteristics Low current breaking for DC circuits R63 … R2100 contactors If the breaking current is lower than 50 % of the contactor rating, a permanent magnet must be added. Please consult us. Refer to blowout code table in DC circuit switching 2 Control circuit The electro-magnet is built with a magnetic circuit and a coil. It is mounted on the right side or on the frame center, in standard. It can be mounted on the left side on request. Rectifier Economy resistor AC control circuit supply: RR electro-magnet The coil is fed from an AC supply via a rectifier and an economy resistor. The control supply frequency is 50/60 Hz in standard. For others frequencies, please consult us. DC control circuit supply (on request): RE electro-magnet The coil is fed from a DC supply via an economy resistor. Latching version (see following pages) Magnetic latching for R63 … R200 Mechanical latching for R500 … R5100 Low consumption coil for R63 … R500 contactors (on request) – Up to 6 times less in control power consumption at holding – Reduced width up to 15 % compared to standard R contactors – Control voltage available: - 24…440 V 50 / 60 Hz - 24…250 V DC – Example of type: IORE63..-LC. Principle Uc A varistor and a lagging contact for holding winding insertion are factory mounted. A2 B1 = Pull-in A3 U B2 = Holding Varistor A1 Only a part of the winding (B1) is energized at closing. After opening the NC contact, the complete coil (B1 + B2) is used for contactor holding. R contactor US catalog | 1SXU106047C0201 13 Contactors with magnetic latching ..AMA type For R63 ... R200 contactors Description Contactors with magnetic latching are very similar to standard contactor in construction and dimensions. Only the electro-magnet and the coil have a specific design. 2 AC operated: ..RR..AMA DC operated: ..R..AMA A permanent magnet is mounted in the upper part of the fixed laminated circuit. The double-winding coil is always fed from d.c. supply (from rectifier for IORR..AMA type) and has: – 1 terminal for "De-latching" + marked "A1" (red) – 1 terminal for "Latching" + marked "A2" (red) – 1 common terminal (blue). Coil windings are only energized at the point of opening and closing of the contactor. 2 NO + 2 NC auxiliary contacts is fitted as standard. For additional auxiliary contact, refer to "Auxiliary contact fitting details". Air-gap Permanent magnet Electro-magnet of contactors ..AMA Applications – Contactors which remain permanently closed, that allows energy saving – Installations where the control circuits are fed from batteries and where it's needed to reduce the power consumption – In case of accidental supply failure, the user knows the state (ON or OFF) of the contactor when the failure occurred – Contactors which must remain closed for safety reasons, even if the control circuit current decreases – Contactors in distribution circuits. The contactor is used as an isolating switch – Protection against accidental failure of the main supply. Operation Contactor closing (latching) The electro-magnet being open, the coil winding (1) is fed via the contact B with a current i1. The strength and direction of the magnetic field produced in this winding is the same as that produced by the permanent magnet. Contactor opening (de-latching) The electro-magnet being closed, the coil winding (2) is fed via the contact A with a current i2. The direction of the field produced by current i2, open the contactor. 1 2 i1 i2 Contactor opening and closing On opening and closing of the contactor, the coil is immediately deenergized by auxiliary contacts B and A mounted on the contactor. B A + - + Block diagram 14 1SXU10607C0201 | R contactor US catalog Mechanical durability 0.2 millions of operating cycles. Contactors with mechanical latching ..AME type Tripping electro-magnet Mechanical latch For R500 ... R5100 contactors Description Contactors with mechanical latching differ from standard contactor by a double electro-magnet (with closing and tripping electro-magnet, electrically separated). 2 A mechanical latch is mounted above the closing electro-magnet. The tripping electro-magnet releases the mechanical latch. 2 NO + 2 NC auxiiliary contacts are fitted as standard for ..AME types. For additional auxiliary contacts, refer to "Auxiliary contact fitting details. AC operated: ..RR..AME Closing electro-magnet Applications – Contactors which remain permanently closed allows energy saving – Installations where the control circuits are fed from batteries and where reduction of power consumption is needed – In case of accidental supply failure, the user knows the state (ON or OFF) of the contactor when the failure occurred – Contactors which must remain closed for safety reasons, even if the control circuit current decreases – Contactors in distribution circuits where the contact serves as an isolating switch – Protection against accidental failure of the main supply. Operation Contactor closing (latching) Once the closing coil is energized, the contactor closes. It remains in this position by the mechanical latch action. The closing coil is de-energized by an electrical interlocking contact. Contactor opening (de-latching) Once the tripping coil is energized, the mechanical latch is released and the contactor opens.The tripping coil is deenergized by an electrical interlocking contact. Mechanical durability 0.2 millions of operating cycles. Variant AMF types with 2 tripping coils are available on request. R contactor US catalog | 1SXU106047C0201 15 Type and order code for R contactors 2 Example: IORE800-30-MT-AME, 220 V DC coil + 1 CA15-F + 1 CA15-O R contactor with RE electro-magnet and circuit for DC operation via an economy resistor, 800 A rating, 3 N.O. main poles, 0 N.C. main pole, with mechanical latching, 220 V DC coil + 1 extra CA15-F (N.O.) auxiliary contact block + 1 extra CA15-O (N.C.) auxiliary contact (total auxiliary contacts: 1 N.O. + 1 N.C.) Type I O R E 800 - 3 0 - MT - AME 220 + 1 CA15-F + 1CA15-O Auxiliary contacts Contactor type N.O. poles I N.C./N.O. poles, break before make N.C./N.O. poles, make before break J Coupler L Contactor for slip-ring motors Coil voltage (refer to following page) N F Open bar mounted O empty No option AMA Magnetic latching (63…200 A) AME Mechanical latching (400…5000 A) LC Low consumption coil Electro-magnet empty AC switching, poles up to 500 V AC AC operated coil + rectifier + economy resistor RR MT AC switching, poles from 500…1000 V AC DC operated coil + economy resistor RE CC DC switching, poles up to 1500 V DC Contactor rating Number of N.C. poles Number of N.O. poles Order code FPL 8 6 2 9 3 2 5 R 0 1 1 6 Contactor rating Operating coil voltage (see table on next page) Equipment type I 1 N 4 I..MT 2 N..MT 5 L 3 J 6 Extra auxiliary contacts (see selection table) Blowout type Electro-magnet type (see table on next page) RR 5 RE 9 RR..CC 6 RE..CC 0 Operation mode 1 Direct 2 Mechanical latching Number of poles Notes: – Additional auxiliary contacts can be ordered separately and mounted by the user if the fixed dimension F doesn't increase (see Auxiliary contact fitting details table). – Order code or contactor rating must be specified when the CA15 auxiliary contact are ordered separately. 16 1SXU10607C0201 | R contactor US catalog Coil voltage and blowout type Selection table Blowout code table in DC circuit switching Standard electromagnetic blowout coil (bidirectional) Used to stretch and break the electric arc from contacts gap to the arc chute. Blowout coil rating according to the operational current. Rating 63 A A 32 40 85 2 Code 125 A A – 170 – 200 A A – 260 – 400 A A – 400 – 500 A A – 550 – £R 4R 5R 6R Permanent magnets blowout (unidirectional) If breaking current < 50% of contactor rating, the electromagnetic field remains too weak to blow the arc, therefore permanent magnets must be added. Rating from 63 to 2100 A Code £R 7R Permanent magnets blowout Pole polarization with permanent magnet + - 1-pole + - 2-pole + - 3-pole R contactor US catalog | 1SXU106047C0201 17 Auxiliary contacts Main characteristics For R63 ... R500 contactors 2 CARB, 1-pole auxiliary contact – 1 N.O. auxiliary contact, generally used for "hold-in" – Ith = 6 A – Fitted on the left side. CA12, 2-pole auxiliary contact blocks CA12-1 CA12-2 1 N.O. + 1 N.C. 2 N.O. – Ith = 12 A – Fitted on the upper part of the electro-magnet. CAOVE, 1-pole auxiliary contact – 1 N.C. auxiliary contact, generally used for electrical interlocking (adjustable) – Ith = 6 A – Fitted on the right side. For R63 ... R5100 contactors CA15, 1-pole adjustable auxiliary contacts Small frame for R63 ... R500 contactors CA15-F CA15-O CA12 1 N.O. 1 N.C. – For R63 ... R500 contactors: auxiliary contact is mounted between the main pole and the electro-magnet – For R800 … R5100 contactors: auxiliary contact is mounted on the auxiliary frame. If more CA15s are needed, they are mounted on the main frame – Ith = 15 A. CAOVE (N.C.) Large frame for R800 ... R5100 contactors CA15 on auxiliary frame CA15 CARB (N.O.) CA15 on main frame 18 1SXU10607C0201 | R contactor US catalog Auxiliary contacts Selection tables Extra auxiliary contact code tables F fixing dimension can change according to the number of CA15 auxiliary contacts. Refer to table below and "Dimensions" section. Type RR, RE (63...500 A) R..AMA (63...200 A) CA12-1 CA12-2 N.O. + N.C. 2 x N.O. – – 1 – 1 – 1 – – 1 1 – 2 – – 1 1 1 3 – – 2 2 1 1 2 – 3 1 – 1 – – 1 – 1 – 1 – 1 – 1 Type RR, RE, RR..AME, RE..AME (≥ 800 A) RR..AMA (63...200 A) CA15F CA15O N.O. N.C. – – – 1 – 2 – 3 – 4 1 – 1 1 1 2 2 – 2 1 2 2 3 – 3 1 3 2 3 3 4 – 4 1 4 2 4 3 5 – 5 1 6 – Code CA15F N.O. – – – – – 1 – 1 – – – – – – 1 2 1 2 2 4 3 CA15O N.C. – – 1 2 – – – – – – – – – – 1 2 1 – 2 – 1 R_££_ R_00_ R_11_ R_12_ R_13_ R_20_ R_21_ R_22_ R_30_ R_31_ R_33_ R_40_ R_42_ R_51_ R_60_ R_61_ R_62_ R_63_ R_64_ R_65_ R_66_ R_67_ Code 2 R_££_ R_00_ R_01_ R_02_ R_03_ R_04_ R_10_ R_11_ R_12_ R_20_ R_21_ R_22_ R_30_ R_31_ R_32_ R_33_ R_40_ R_41_ R_42_ R_43_ R_50_ R_51_ R_60_ The above tables indicate the main auxiliary contact combinations. For other combinations, please consult us. Auxiliary contact fitting details Contactor types Rating Auxiliary contacts fitted as standard Additional auxiliary contacts without increasing dimension F (1) CA15 IORR IORE IORR..MT IORR..CC IORE..MT IORE..CC IOR..AMA IORR..AMA IORR..AME IORE..AME NORR..MT NORR..CC NORE..MT NORE..CC A 800…5100 1 CA15-F + 1 CA15-O 63…500 800…5100 63…500 800…5100 63…500 800…5100 63…200 63…200 400...500 800…5100 63...200 800 63...200 800 1 1 1 1 1 1 1 1 1 1 1 1 + + + + + + 1 1 1 1 1 1 1 1 1 1 CARB CA15-F CARB CA15-F CARB CA15-F CARB CARB CARB CA15-F CARB CA15-F + + + + CAOVE CA15-O CAOVE CA15-O CAOVE CA15-O CAOVE CA15-O CAOVE CA15-O + + + + + + 2 max. CA12 Single block (incl. 2 contacts) - 2 2 2 1 5 2 2 1 1 1 1 - max. + max. + max. + max. max. max. + max. max. max. max. max. CA12 Double block (incl. 4 contacts) + 1 + 1 + 1 + 1 + 1 - max. max. max. max. max. (1) More CA15 auxiliary contacts can be fitted with increasing dimension F. See fixing dimension F in "Dimensions" section. R contactor US catalog | 1SXU106047C0201 19 3 20 1SXU10607C0201 | R contactor US catalog AC circuit switching Overview 22 Ordering details Power circuit up to 500 V AC IORR AC operated 24 3 Power circuit up to 1000 V AC IORR..MT AC operated 25 Power circuit up to 500 V AC, with mechanical latching IORR..AME AC operated 26 Power circuit up to 1000 V AC, with latching IORR..MT-AMA AC operated 27 IORR..MT-AME AC operated 27 Technical data 28 Type and order code for R contactors 18 R contactor US catalog | 1SXU106047C0201 21 R contactors for AC circuit switching Rated operational voltage 3 Ue from 500 up to 1000 V AC Contactor type IORR63..MT Categories AC-1 IORR125..MT IORR200..MT IORR400..MT IORR500..MT IORR800..MT Ie 85 A 170 A 260 A 400 A 550 A 800 A Ie 85 A 160 A 260 A 400 A 550 A 800 A Ue at 40 °C AC-3 690 V AC 1000 V AC max. AC-3 690 V AC Ie 56 A Power 80 kW 105 A 180 A 280 A 380 A 580 A 150 kW 240 kW 400 kW 540 kW 780 kW *120 V 60Hz coil and 2 N.O. + 2 N.C. auxiliary contacts as standard Rated operational voltage Ue up to 500 V AC Contactor type – Categories AC-1 AC-3 AC-3 Ue at 40 °C Ie From 85 A to 550 A, select above IOR..-MT 900 A 380-415-440 V AC Ie – 800 A 500 V AC max. Ie – 800 A Power – 450 kW 400 V AC *120 V 60Hz coil and 2 N.O. + 2 N.C. auxiliary contacts as standard 22 IORR800 1SXU10607C0201 | R contactor US catalog 3 IORR1400..MT IORR1700..MT IORR2100..MT IORR2500..MT IORR3200..MT IORR3800..MT IORR4500..MT IORR5100..MT 1250 A 1650 A 1850 A 2200 A 3000 A 3500 A 4000 A 4500 A 970 A 1170 A 1270 A – – – – – 610 A 680 A 810 A – – – – – 1000 kW 1200 kW 1300 kW – – – – – IORR1000 IORR1400 IORR1700 IORR2100 IORR2500 IORR3200 IORR3800 IORR4500 IORR5100 1000 A 1350 A 1650 A 2000 A 2400 A 3200 A 3800 A 4500 A 5000 A 800 A 1080 A 1260 A 1520 A – – – – – 800 A 1080 A 1220 A 1340 A – – – – – 450 kW 630 kW 750 kW 900 kW – – – – – R contactor US catalog | 1SXU106047C0201 23 IORR contactors Power circuit up to 500 V AC Control circuit 120V 60Hz Description 1SBC104038F0000 IORR contactors are used for controlling AC power circuits up to 500 V AC. 3 IORR800-30 These contactors are designed with: – variable number of poles according to the application – control circuit: AC operated – 2 NO + 2 NC auxiliary contacts available, as standard Ordering details AC-3 Rated operational power 380 V 440 V 500 V 400 V 415 V kW kW kW 450 500 560 AC-1 Number Rated control Auxiliary Type of poles circuit voltage contacts Uc fitted (2) current (1) ≤ 440 V θ ≤ 40 °C A 800 A 900 - - - - 1000 630 710 800 1080 1350 750 800 900 1260 1650 900 1000 1000 1520 2000 - - - - 2400 - - - - 3200 - - - - 3800 - - - - 4500 - - - - 5000 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 2 3 2 3 2 3 2 3 V 50/60 Hz 120V 120V 120V 120V 120V 120V 120V 120V 120V 120V (1) Other control voltages, please contact us. (2) Other auxiliary contact arrangements, please contact us. 24 1SXU10607C0201 | R contactor US catalog 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 IORR800-20 IORR800-30 IORR800-40 IORR1000-20 IORR1000-30 IORR1000-40 IORR1400-20 IORR1400-30 IORR1400-40 IORR1700-20 IORR1700-30 IORR1700-40 IORR2100-20 IORR2100-30 IORR2100-40 IORR2500-20 IORR2500-30 IORR3200-20 IORR3200-30 IORR3800-20 IORR3800-30 IORR4500-20 IORR4500-30 IORR5100-20 IORR5100-30 Order code Weight Pkg (1 pce) FPL8615215R2113 FPL8615315R2113 FPL8615415R2113 FPL8715215R2113 FPL8715315R2113 FPL8715415R2113 FPL6115215R2113 FPL6115315R2113 FPL6115415R2113 FPL6215215R2113 FPL6215315R2113 FPL6215415R2113 FPL6315215R2113 FPL6315315R2113 FPL6315415R2113 FPL6715215R2113 FPL6715315R2113 FPL6515215R2113 FPL6515315R2113 FPL6615215R2113 FPL6615001R2113 FPL6815215R2113 FPL6815001R2113 FPL6915001R2113 FPL6915002R2113 kg 38 48 58 38 48 58 40 50 63 44 56 72 48 62 78 On request On request On request On request On request IORR..MT contactors Power circuit up to 1000 V AC Control circuit 120V 50/60 Hz Description 1SBC104041F0000 IORR..MT contactors are used for controlling AC power circuits from 500 up to 1000 V AC. IORR1400-20-MT These contactors are designed with: – variable number of poles according to the application – control circuit: AC operated – 2 NO + 2 NC auxiliary contacts available, as standard Ordering details AC-3 Rated operational power (3) current 690 V 1000 V ≤ 690 V AC-1 kW 80 kW 80 A 85 A 85 150 150 160 170 240 250 260 260 400 400 400 400 540 550 550 550 780 850 800 800 1000 900 970 1250 1200 1000 1170 1650 1300 1200 1270 1850 - - - 2200 - - - 3000 - - - 3500 - - - 4000 - - - 4500 Number of poles θ ≤ 40 °C 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 2 3 2 3 2 3 Rated control Auxiliary Type circuit voltage contacts Uc fitted (2) (1) V 50/60 Hz 120V 120V 120V 120V 120V 120V 120V 120V 120V 120V 120V 120V 120V 120V 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 IORR63-20-MT IORR63-30-MT IORR63-40-MT IORR125-20-MT IORR125-30-MT IORR125-40-MT IORR200-20-MT IORR200-30-MT IORR200-40-MT IORR400-20-MT IORR400-30-MT IORR400-40-MT IORR500-20-MT IORR500-30-MT IORR500-40-MT IORR800-20-MT IORR800-30-MT IORR800-40-MT IORR1400-20-MT IORR1400-30-MT IORR1400-40-MT IORR1700-20-MT IORR1700-30-MT IORR1700-40-MT IORR2100-20-MT IORR2100-30-MT IORR2100-40-MT IORR2500-20-MT IORR2500-30-MT IORR2500-40-MT IORR3200-20-MT IORR3200-30-MT IORR3800-20-MT IORR3800-30-MT IORR4500-20-MT IORR4500-30-MT IORR5100-20-MT IORR5100-30-MT Order code Weight 3 Pkg (1 pce) FPL7125216R2113 FPL7125386R2113 FPL7125416R2113 FPL7425215R2113 FPL7425315R2113 FPL7425415R2113 FPL7625215R2113 FPL7625315R2113 FPL7625415R2113 FPL9425215R2113 FPL9425315R2113 FPL9425415R2113 FPL8325215R2113 FPL8325315R2113 FPL8325415R2113 FPL8625215R2113 FPL8625315R2113 FPL8625415R2113 FPL6125215R2113 FPL6125315R2113 FPL6125415R2113 FPL6225215R2113 FPL6225315R2113 FPL6225415R2113 FPL6325215R2113 FPL6325315R2113 FPL6325415R2113 FPL6725215R2113 FPL6725315R2113 FPL6725415R2113 FPL6525215R2113 FPL6525315R2113 FPL6625215R2113 FPL6625001R2113 FPL6825215R2113 FPL6825002R2113 FPL6925001R2113 FPL6925002R2113 kg 4.2 5.2 6.2 6.2 8.2 10.2 9.6 12.6 15.6 19.2 25 30.8 19.7 25.5 31.3 40 51 62 42 52 65 47 61 74 52 68 82 71 On request 83 On request 95 On request On request On request (1) Other control voltages, please contact us. (2) Other auxiliary contact arrangements, please contact us. (3) Power circuit above 1000 V AC, please contact us. R contactor US catalog | 1SXU106047C0201 25 IORR..AME contactors Power circuit up to 500 V AC, with mechanical latching Control circuit 120V 50/60 Hz Description 1SBC104044F0000 IORR..AME contactors are used for controlling AC power circuits up to 500 V AC. 3 These contactors are designed with: – mechanical latching – variable number of poles according to the application – control circuit: AC operated – 2 NO + 2 NC auxiliary contacts available Ordering details IORR800-30-AME AC-3 Rated operational power 380 V 440 V 500 V 400 V 415 V kW kW kW 450 500 560 AC-1 Nb of poles current ≤ 440 V θ ≤ 40 °C A 800 A 900 2 3 4 2 3 4 2 3 4 2 3 4 2 3 4 2 3 2 3 Rated control Auxiliary Type circuit voltage contacts Uc fitted (2) (1) V 50/60 Hz 120V 120V 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 IORR800-20-AME IORR800-30-AME IORR800-40-AME IORR1000-20-AME IORR1000-30-AME IORR1000-40-AME IORR1400-20-AME IORR1400-30-AME IORR1400-40-AME IORR1700-20-AME IORR1700-30-AME IORR1700-40-AME IORR2100-20-AME IORR2100-30-AME IORR2100-40-AME IORR2500-20-AME IORR2500-30-AME IORR3200-20-AME IORR3200-30-AME FPL8615225R2223 FPL8615325R2223 FPL8615425R2223 FPL8715225R2223 FPL8715325R2223 FPL8715425R2223 FPL6115225R2223 FPL6115325R2223 FPL6115425R2223 FPL6215225R2223 FPL6215325R2223 FPL6215425R2223 FPL6315225R2223 FPL6315325R2223 FPL6315425R2223 FPL6715225R2223 FPL6715325R2223 FPL6515225R2223 FPL6515325R2223 - - - 1000 630 710 800 1080 1350 750 800 900 1260 1650 900 1000 1000 1520 2000 - - - - 2400 - - - - 3200 - - - - 3800 2 120V 2 2 IORR3800-20-AME FPL6615225R2223 - - - - 4500 2 120V 2 2 IORR4500-20-AME FPL6815225R2223 120V 120V 120V 120V 120V 1SXU10607C0201 | R contactor US catalog Weight Pkg (1 pce) - (1) Other control voltages please consult us. (2) Other auxiliary contact arrangements, please consult us. 26 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Order code kg 48 58 68 48 58 68 50 60 73 54 66 82 58 72 88 On request On request On request On request IORR..MT-AMA and IORR..MT-AME contactors Power circuit up to 1000 V AC, with latching Control circuit 120V 50/60 Hz Description 1SBC104044F0000 IORR..MT-AMA and IORR..MT-AME contactors are used for controlling AC power circuits from 500 up to 1000 V AC. IORR800-30-MT-AME These contactors are designed with: – magnetic latching, AMA types – mechanical latching, AME types – variable number of poles according to the application – control circuit: AC operated – 2 NO + 2 NC auxiliary contact available for AMA version, as standard – 2 NO + 2 NC auxiliary contacts available for AME version 3 Ordering details AC-3 AC-1 Number of poles Rated operational power (3) current 690 V 1000 V ≤ 690 V θ ≤ 40 °C Rated control Auxiliary Type circuit voltage contacts Uc fitted (2) (1) kW V 50/60 Hz kW A A Magnetic latching 80 80 85 85 150 150 160 170 240 250 260 260 Mechanical latching 400 400 400 400 540 550 550 550 780 850 800 800 1000 900 970 1250 1200 1000 1170 1650 1300 1200 1270 1850 - - - 2200 - - - 3000 - - - 3500 - - - 4000 2 3 4 2 3 4 2 3 4 2 3 2 3 2 3 2 3 2 3 2 3 2 3 2 3 2 3 2 120V 120V 120V 120V 120V 120V 120V 120V 120V 120V 120V 120V 120V Order code Weight Pkg (1 pce) kg 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 IORR63-20-MT-AMA IORR63-30-MT-AMA IORR63-40-MT-AMA IORR125-20-MT-AMA IORR125-30-MT-AMA IORR125-40-MT-AMA IORR200-20-MT-AMA IORR200-30-MT-AMA IORR200-40-MT-AMA FPL7125236R2123 FPL7125336R2123 FPL7125436R2123 FPL7425235R2123 FPL7425335R2123 FPL7425435R2123 FPL7625235R2123 FPL7625335R2123 FPL7625435R2123 3.9 4.9 5.9 5.9 7.9 9.9 9.2 12.2 15.2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 IORR400-20-MT-AME IORR400-30-MT-AME IORR500-20-MT-AME IORR500-30-MT-AME IORR800-20-MT-AME IORR800-30-MT-AME IORR1400-20-MT-AME IORR1400-30-MT-AME IORR1700-20-MT-AME IORR1700-30-MT-AME IORR2100-20-MT-AME IORR2100-30-MT-AME IORR2500-20-MT-AME IORR2500-30-MT-AME IORR3200-20-MT-AME IORR3200-30-MT-AME IORR3800-20-MT-AME IORR3800-30-MT-AME IORR4500-20-MT-AME FPL9425225R2123 FPL9425325R2123 FPL8325225R2123 FPL8325325R2123 FPL8625225R2123 FPL8625325R2123 FPL6125225R2123 FPL6125325R2123 FPL6225225R2123 FPL6225325R2123 FPL6325225R2123 FPL6325325R2123 FPL6725225R2123 FPL6725325R2123 FPL6525225R2123 FPL6525325R2123 FPL6625225R2123 FPL6625325R2123 FPL6825225R2123 24.2 30 24.2 30 50 61 52 62 57 71 62 78 On request On request On request On request (1) Other control voltages, please consult us. (2) Other auxiliary contact arrangements, please consult us. (3) Power circuit above 1000 V AC, please consult us. R contactor US catalog | 1SXU106047C0201 27 IORR800 … IORR2100 contactors Technical data Main pole - Utilization characteristics according to IEC 3 AC operated Contactor types Standards Rated operational voltage Ue max. Rated frequency (without derating) Number of poles Conventional free-air thermal current Ith acc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C With conductor cross-sectional area AC-1 Utilization category For air temperature close to contactor θ ≤ 40 °C Ie / Rated operational current AC-1 θ ≤ 55 °C Ue max. ≤ 500 V, 50/60 Hz With conductor cross-sectional area AC-3 Utilization category For air temperature close to contactor θ ≤ 55 °C Ie / Max. rated operational current AC-3 M 3 IORR800 IORR1000 IORR1400 IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1 500 V 25…60 Hz (for > 60...400 Hz please consult us) 2...4 IORR1700 IORR2100 1000 A 600 mm² 900 840 θ ≤ 70 °C 720 600 380-415-440 V 500 V A A A mm² 800 A 800 A 1100 A 600 mm² 1400 A 1000 mm² 1700 A 1500 mm² 2100 A 2000 mm² 1000 A 930 A 800 A 600 mm² 1350 1180 1000 1000 1650 1450 1250 1500 2000 1750 1500 2000 - 1080 A 1080 A 1260 A 1220 A 1520 A 1340 A 630 kW 710 kW 800 kW 750 kW 800 kW 900 kW 900 kW 1000 kW 1000 kW 1600 A 11000 A 9000 A 5000 A 3700 A 2000 A 2000 A 13000 A 11000 A 6000 A 4400 A 2400 A 2500 A 15000 A 12200 A 7000 A 5000 A 2800 A 10000 A 19000 A 19000 A 0.10 mΩ 150 cycles/h 150 cycles/h - 13500 A 21000 A 21000 A 0.09 mΩ 120 cycles/h 120 cycles/h A A A mm² A A A mm² A A A mm² Rated operational power AC-3 M 3 380-415 V 440 V 500 V 450 kW 500 kW 560 kW 10 x Ie AC-3 acc. to IEC 60947-4-1 8 x Ie AC-3 acc. to IEC 60947-4-1 Rated making capacity AC-3 Rated breaking capacity AC-3 Short-circuit protection device for contactors without thermal overload relay - Motor protection excluded Circuit breaker 1250 A 1 s 9000 A Rated short-time withstand current Icw 10 s 8000 A at 40 °C ambient temperature, 30 s 4000 A in free air from a cold state 1 min 3000 A 15 min 1600 A Maximum breaking capacity at 500 V 6400 A cos φ = 0.35 Maximum making capacity 14000 A Dynamical withstand of pole 14000 A Impedance per pole 0.18 mΩ AC-1 300 cycles/h Maximum electrical switching frequency AC-3 300 cycles/h AC-4 150 cycles/h Mechanical durability Number of operating cycles 5 millions cycles Max. switching frequency 1200 cycles/h 1250 9000 8000 4000 3000 1600 A A A A A A 6400 A 14000 A 14000 A 0.18 mΩ - 2 millions cycles 600 cycles/h Note: These characteristics are suitable for IOR..AME contactor versions (except for mechanical durability = 0.2 millions of operating cycles). 28 1SXU10607C0201 | R contactor US catalog 24000 A 24000 A 0.08 mΩ IORR2500 … IORR5100 contactors Technical data Main pole - Utilization characteristics according to IEC AC operated Contactor types Standards Rated operational voltage Ue max. Rated frequency (without derating) Number of poles Conventional free-air thermal current Ith acc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C With conductor cross-sectional area AC-1 Utilization category For air temperature close to contactor θ ≤ 40 °C Ie / Rated operational current AC-1 θ ≤ 55 °C Ue max. ≤ 500 V, 50/60 Hz With conductor cross-sectional area Rated making capacity AC-1 Rated breaking capacity AC-1 AC-3 Utilization category For air temperature close to contactor θ ≤ 55 °C Ie / Max. rated operational current AC-3 M 3 IORR2500 IORR3200 IORR3800 IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1 500 V 25…60 Hz (for > 60...400 Hz please consult us) 2...4 IORR4500 IORR5100 2500 A 2000 mm² 4500 A 4000 mm² 5000 A 4000 mm² 3200 A 3000 mm² 3 2400 A 3200 A 2100 A 2810 A θ ≤ 70 °C 1760 A 2350 A 2000 mm² 3000 mm² 1.5 x Ie AC-1 acc. to IEC 60947-4-1 1.5 x Ie AC-1 acc. to IEC 60947-4-1 380-415-440 V 500 V 3800 A 3000 mm² 3800 3330 2790 3000 A A A mm² 4500 3950 3300 4000 A A A mm² 5000 4390 3670 4000 A A A mm² Please consult us Please consult us Short-circuit protection device for contactors without thermal overload relay - Motor protection excluded Circuit breaker 1 s 20000 A Rated short-time withstand current Icw 10 s 15000 A at 40 °C ambient temperature, 30 s 8000 A in free air from a cold state 1 min 6000 A 15 min 3000 A Maximum making capacity 24000 A Dynamical withstand of pole 24000 A Impedance per pole 0.05 mΩ AC-1 60 cycles/h Maximum electrical switching frequency Mechanical durability Number of operating cycles 2 millions cycles Max. switching frequency 600 cycles/h 21000 A 18000 A 10000 A 7000 A 4000 A 26000 A 26000 A 0.045 mΩ 24000 A 19000 A 11000 A 7500 A 4500 A 29000 A 29000 A 0.040 mΩ 40 cycles/h 28000 A 21000 A 12000 A 8000 A 5000 A 32000 A 32000 A 0.030 mΩ 30000 A 24000 A 13000 A 9000 A 5500 A 32000 A 32000 A 0.027 mΩ 1 million cycles 300 cycles/h Note: These characteristics are suitable for IOR..AME contactor versions (except for mechanical durability = 0.2 millions of operating cycles). R contactor US catalog | 1SXU106047C0201 29 IORR63..MT … IORR500..MT contactors Technical data Main pole - Utilization characteristics according to IEC 3 AC operated Contactor types Standards Rated operational voltage Ue max. Rated frequency (without de-rating) Number of poles Conventional free-air thermal current Ith acc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C With conductor cross-sectional area AC-1 Utilization category For air temperature close to contactor θ ≤ 40 °C Ie / Rated operational current AC-1 θ ≤ 55 °C Ue max. ≤ 1000 V, 50/60 Hz With conductor cross-sectional area AC-3 Utilization category For air temperature close to contactor θ ≤ 55 °C Ie / Max. rated operational current AC-3 M 3 IORR63..MT IORR125..MT IORR200..MT IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1 1000 V 25…60 Hz (for > 60...400 Hz please consult us) 2...4 IORR400..MT IORR500..MT 85 A 25 mm² 85 76 θ ≤ 70 °C 68 25 A A A mm² 170 A 70 mm² 275 A 150 mm² 400 A 240 mm² 550 A 400 mm² 170 A 150 A 135 A 70 mm² 260 230 205 150 400 350 300 240 550 490 400 400 160 A 105 A 260 A 180 A 400 A 280 A 550 A 380 A 240 kW 250 kW 400 kW 400 kW 540 kW 550 kW 200 A 2250 A 1280 A 680 A 450 A 250 A 315 A 3800 A 2080 A 1040 A 730 A 390 A 500 A 6000 A 3200 A 1600 A 1200 A 600 A 630 A 8400 A 4400 A 2200 A 1680 A 840 A 1280 A 850 A 2400 A 2500 A 1.20 mΩ 2100 A 1450 A 4000 A 4500 A 0.60 mΩ 4480 A 3050 A 7000 A 8000 A 0.40 mΩ 4480 A 3050 A 9000 A 10000 A 0.35 mΩ 690 V 1000 V 85 A 56 A 690 V 1000 V 80 kW 150 kW 80 kW 150 kW 10 x Ie AC-3 acc. to IEC 60947-4-1 8 x Ie AC-3 acc. to IEC 60947-4-1 A A A mm² A A A mm² A A A mm² Rated operational power AC-3 M 3 Rated making capacity AC-3 Rated breaking capacity AC-3 Short-circuit protection device for contactors without thermal overload relay - Motor protection excluded Ue ≤ 1000 V AC - gG type fuse 100 A Ue ≤ 1000 V AC - L type fuse 1 s 1150 A Rated short-time withstand current Icw 10 s 680 A at 40 °C ambient temperature, 30 s 310 A in free air from a cold state 1 min 230 A 15 min 120 A Maximum breaking capacity at 690 V 680 A cos φ = 0.45 at 1000 V 450 A (cos φ = 0.35 for Ie > 100 A) Maximum making capacity 1300 A Dynamical withstand of pole 1400 A Impedance per pole 1.8 mΩ AC-1 300 cycles/h Maximum electrical switching frequency AC-3 300 cycles/h AC-4 150 cycles/h Mechanical durability Number of operating cycles 5 millions cycles Max. switching frequency 1200 cycles/h Note: These characteristics are suitable for IOR..MT-AMA and IOR..MT-AME contactors with latching versions (except for mechanical durability = 0.2 millions of operating cycles). 30 1SXU10607C0201 | R contactor US catalog IORR800..MT … IORR2100..MT contactors Technical data Main pole - Utilization characteristics according to IEC AC operated Contactor types Standards Rated operational voltage Ue max. Rated frequency (without derating) Number of poles Conventional free-air thermal current Ith acc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C With conductor cross-sectional area AC-1 Utilization category For air temperature close to contactor θ ≤ 40 °C Ie / Rated operational current AC-1 θ ≤ 55 °C Ue max. ≤ 690 V, 50/60 Hz IORR800..MT IORR1400..MT IORR1700..MT IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1 1000 V 25…60 Hz (for > 60...400 Hz please consult us) 2...4 IORR2100..MT 800 A 500 mm² 1850 A 1500 mm² M 3 1700 A 1500 mm² 3 800 A 740 A θ ≤ 70 °C 640 A Ie / Rated operational current AC-1 Ue max. ≤ 1000 V, 50/60 Hz With conductor cross-sectional area AC-3 Utilization category For air temperature close to contactor θ ≤ 55 °C Ie / Max. rated operational current AC-3 1300 A 1000 mm² 1250 A 1100 A 900 A 1650 A 1450 A 1250 A 1850 A 1620 A 1400 A 800 A 500 mm² 1220 A 1000 mm² 1360 A 1500 mm² 1620 A 1500 mm² 690 V 1000 V 800 A 580 A 970 A 610 A 1170 A 680 A 1270 A 810 A 690 V 1000 V 780 kW 1000 KW 850 kW 900 kW 10 x Ie AC-3 acc. to IEC 60947-4-1 8 x Ie AC-3 acc. to IEC 60947-4-1 1200 kW 1000 kW 1300 kW 1200 kW 1600 A 11000 A 9000 A 5000 A 3600 A 1900 A 2000 A 13000 A 11000 A 6000 A 4200 A 2200 A 2500 A 15000 A 12000 A 7000 A 4600 A 2600 A 8500 A 5000 A 19000 A 19000 A 0.24 mΩ 150 cycles/h 150 cycles/h 11000 A 8500 A 21000 A 21000 A 0.18 mΩ 120 cycles/h 120 cycles/h 24000 A 24000 A 0.17 mΩ θ ≤ 40 °C Rated operational power AC-3 M 3 Rated making capacity AC-3 Rated breaking capacity AC-3 Short-circuit protection device for contactors without thermal overload relay - Motor protection excluded Circuit breaker 1250 A 1 s 9000 A Rated short-time withstand current Icw 10 s 6400 A at 40 °C ambient temperature, 30 s 3200 A in free air from a cold state 1 min 2100 A 15 min 1200 A Maximum breaking capacity at 690 V 6400 A cos φ = 0.45 at 1000 V 4650 A (cos φ = 0.35 for Ie > 100 A) Maximum making capacity 14000 A Dynamical withstand of pole 14000 A Impedance per pole 0.28 mΩ AC-1 300 cycles/h Maximum electrical switching frequency AC-3 300 cycles/h Mechanical durability Number of operating cycles 5 millions cycles Max. switching frequency 1200 cycles/h 2 millions cycles 600 cycles/h Note: These characteristics are suitable for IOR..MT-AME contactor versions (except for mechanical durability = 0.2 millions of operating cycles). R contactor US catalog | 1SXU106047C0201 31 IORR2500..MT … IORR5100..MT contactors Technical data Main pole - Utilization characteristics according to IEC 3 AC operated Contactor types Standards Rated operational voltage Ue max. Rated frequency (without derating) Number of poles Conventional free-air thermal current Ith acc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C With conductor cross-sectional area AC-1 Utilization category For air temperature close to contactor θ ≤ 40 °C Ie / Rated operational current AC-1 θ ≤ 55 °C Ue max. ≤ 690 V, 50/60 Hz With conductor cross-sectional area Rated making capacity AC-1 Rated breaking capacity AC-1 AC-3 Utilization category For air temperature close to contactor θ ≤ 55 °C Ie / Max. rated operational current AC-3 IORR2500..MT IORR3200..MT IORR3800..MT IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1 690 V 25…60 Hz (for > 60...400 Hz please consult us) 2...4 IORR4500..MT IORR5100..MT 2200 A 2000 mm² 3500 A 3000 mm² 4000 A 4000 mm² 4500 A 4000 mm² 3500 3070 2570 3000 4000 3510 2940 4000 4500 3950 3300 4000 3000 A 3000 mm² 2200 A 3000 A 1930 A 2630 A θ ≤ 70 °C 1620 A 2200 A 2000 mm² 3000 mm² 1.5 x Ie AC-1 acc. to IEC 60947-4-1 1.5 x Ie AC-1 acc. to IEC 60947-4-1 A A A mm² A A A mm² A A A mm² M 3 690 V Please consult us Short-circuit protection device for contactors without thermal overload relay - Motor protection excluded Circuit breaker 1 s 20000 A Rated short-time withstand current Icw 10 s 15000 A at 40 °C ambient temperature, 30 s 8000 A in free air from a cold state 1 min 6000 A 15 min 3000 A Maximum making capacity 24000 A Dynamical withstand of pole 24000 A Impedance per pole 0.12 mΩ AC-1 60 cycles/h Maximum electrical switching frequency Mechanical durability Number of operating cycles 2 millions cycles Max. switching frequency 600 cycles/h 21000 A 18000 A 10000 A 7000 A 4000 A 26000 A 26000 A 0.09 mΩ 24000 A 19000 A 11000 A 7500 A 4500 A 29000 A 29000 A 0.085 mΩ 40 cycles/h 28000 A 21000 A 12000 A 8000 A 5000 A 32000 A 32000 A 0.06 mΩ 1 million cycles 300 cycles/h Note: These characteristics are suitable for IOR..MT-AME contactor versions (except for mechanical durability = 0.2 millions of operating cycles). 32 1SXU10607C0201 | R contactor US catalog 30000 A 24000 A 13000 A 9000 A 5500 A 32000 A 32000 A 0.055 mΩ Notes R contactor US catalog | 1SXU106047C0201 33 4 34 1SXU10607C0201 | R contactor US catalog DC circuit switching Overview 36 Ordering details Power circuit up to 1500 V DC IORR..CC AC operated 38 Power circuit up to 600 V DC acc. to UL / CSA IORR..CC-U AC operated 39 Power circuit up to 1500 V DC, with latching IORR..CC-AMA AC operated 40 IORR..CC-AME AC operated 40 Technical data 42 Type and order code for R contactors 18 R contactor US catalog | 1SXU106047C0201 4 35 R contactors for DC circuit switching Rated operational voltage Ue up to 4 1500 V DC Contactor type IORR63 ..CC Number of poles Categories in series IORR125 ..CC IORR200 ..CC IORR400 ..CC IORR500 ..CC Ue max. DC-1 500 V DC Ie 85 A 170 A 275 A 400 A 550 A DC-3 / DC-5 500 V DC Ie 68 A 125 A 205 A 350 A 500 A DC-1 1000 V DC Ie 85 A 170 A 275 A 400 A* 550 A* DC-3 / DC-5 1000 V DC Ie 68 A 125 A 205 A 350 A 500 A DC-1 1500 V DC Ie 85 A* 170 A* 275 A* 400 A* 550 A* DC-3 / DC-5 1500 V DC Ie 68 A* 125 A* 205 A* 350 A* 500 A* IORR1000-10-CC IORR1400-10-CC IORR1700-10-CC IORR2100-10-CC 1000 A 1300 A 1700 A 2000 A 1 pole 2 poles 3 poles * Ue max. = 1500 V DC, version with increased insulation for 1000 V DC < Ue ≤ 1500 V DC, please consult us. *120 V 60Hz coil and 2 N.O. + 2 N.C. auxiliary contacts as standard Contactors UL / CSA approved Rated operational voltage Ue up to 600 V DC Contactor type IORR800-10-CC U max. 1 pole General use 600 V DC Ie 800 A *120 V 60Hz coil and 2 N.O. + 2 N.C. auxiliary contacts as standard 36 1SXU10607C0201 | R contactor US catalog 4 IORR800..CC IORR1000..CC IORR1400..CC IORR1700..CC IORR2100..CC IORR2500..CC IORR3200..CC IORR3800..CC IORR4500..CC IORR5100..CC 750 V DC 800 A 1000 A 1250 A 1600 A 2000 A 2300 A 3200 A 3800 A 4500 A 5000 A 600 V DC 720 A 1000 A 1250 A 1600 A 2000 A On request On request On request On request On request 1500 V DC 800 A 1000 A 1250 A 1600 A 2000 A 2300 A 3200 A 3800 A 4500 A 5000 A Ue max. 1000 V DC 720 A 1000 A 1250 A 1600 A 2000 A On request On request On request On request On request 1500 V DC 800 A 1000 A 1250 A 1600 A 2000 A 2300 A 3200 A 3800 A 4500 A 5000 A 1500 V DC 720 A 1000 A 1250 A 1600 A 2000 A On request On request On request On request On request R contactor US catalog | 1SXU106047C0201 37 IORR..CC contactors Power circuit up to 1500 V DC Control circuit 120V 50/60 Hz Description 1SBC104034F0000 IORR..CC contactors are used for controlling DC power circuits up to 1500 V DC. These contactors are designed with: – variable number of poles according to the application – control circuit: AC operated – 2 NO + 2 NC auxiliary contacts available, as standard Blowout in DC circuit switching IORR800-10-CC If the breaking current is lower than 50 % of the contactor rating, permanent magnet must be added, see blowout code table. Ordering details Number Rated con- Auxiliary IEC of poles trol circuit contacts DC-1 DC-3 / DC-5 fitted (2) voltage Rated operationnal Rated operationnal Uc current voltage (3) current voltage (3) (1) A V DC A V DC V 50/60 Hz 85 500 68 500 1 120V 2 2 1000 1000 2 2 2 1500 1500 3 2 2 170 500 125 500 1 120V 2 2 1000 1000 2 2 2 1500 1500 3 2 2 275 500 205 500 1 120V 2 2 1000 1000 2 2 2 1500 1500 3 2 2 400 500 350 500 1 120V 2 2 1000 1000 2 2 2 1500 1500 3 2 2 550 500 500 500 1 120V 2 2 1000 1000 2 2 2 1500 1500 3 2 2 800 750 720 600 1 120V 2 2 1500 1000 2 2 2 1500 3 2 2 1000 750 1000 600 1 120V 2 2 1500 1000 2 2 2 1500 3 2 2 1250 750 1250 600 1 120V 2 2 1500 1000 2 2 2 1500 3 2 2 1600 750 1600 600 1 120V 2 2 1500 1000 2 2 2 1500 3 2 2 2000 750 2000 600 1 120V 2 2 1500 1000 2 2 2 1500 3 2 2 2300 750 On On 1 120V 2 2 request request 1500 2 2 2 3 2 2 3200 750 On On 1 120V 2 2 request request 1500 2 2 2 3 2 2 3800 750 On On 1 120V 2 2 request request 1500 2 2 2 3 2 2 4500 750 On On 1 120V 2 2 request request 1500 2 2 2 3 2 2 5000 750 On On 1 120V 2 2 request request 1500 2 2 2 3 2 2 4 (1) Other control voltages, please consult us. (2) Other auxiliary contact arrangements, please consult us. (3) Power circuit above 1500 V DC, please consult us. 38 1SXU10607C0201 | R contactor US catalog Type Order code Weight pkg (1 pce) IORR63-10-CC IORR63-20-CC IORR63-30-CC IORR125-10-CC IORR125-20-CC IORR125-30-CC IORR200-10-CC IORR200-20-CC IORR200-30-CC IORR400-10-CC IORR400-20-CC IORR400-30-CC IORR500-10-CC IORR500-20-CC IORR500-30-CC IORR800-10-CC-U IORR800-20-CC IORR800-30-CC IORR1000-10-CC-U IORR1000-20-CC IORR1000-30-CC IORR1400-10-CC-U IORR1400-20-CC IORR1400-30-CC IORR1700-10-CC-U IORR1700-20-CC IORR1700-30-CC IORR2100-10-CC-U IORR2100-20-CC IORR2100-30-CC IORR2500-10-CC IORR2500-20-CC IORR2500-30-CC IORR3200-10-CC IORR3200-20-CC IORR3200-30-CC IORR3800-10-CC IORR3800-20-CC IORR3800-30-CC IORR4500-10-CC IORR4500-20-CC IORR4500-30-CC IORR5100-10-CC IORR5100-20-CC IORR5100-30-CC FPL7116116R2113 FPL7116216R2113 On request FPL7416115R2113 FPL7416215R2113 On request FPL7616115R2113 FPL7616215R2113 On request FPL9416115R2113 FPL9416215R2113 On request FPL8316115R2113 FPL8316215R2113 On request FPL8616195R2113 FPL8616215R2113 FPL8616315R2113 FPL8716195R2113 FPL8716215R2113 FPL8716315R2113 FPL6616195R2113 FPL6116215R2113 FPL6116315R2113 FPL6216195R2113 FPL6216215R2113 FPL6216315R2113 FPL6316195R2113 FPL6316215R2113 FPL6316315R2113 FPL6716115R2113 FPL6716215R2113 FPL6716315R2113 FPL6516115R2113 FPL6516215R2113 FPL6516315R2113 FPL6616115R2113 FPL6616215R2113 FPL6616001R2113 FPL6816115R2113 FPL6816215R2113 FPL6816001R2113 FPL6916115R2113 FPL6916002R2113 FPL6916001R2113 kg 3.2 4.2 5.2 4.2 6.2 8.2 6.6 9.6 12.6 13.9 19.7 25.5 13.9 19.7 25.5 30 40 51 31 42 50 32 42 52 34 47 61 37 52 68 45 71 On request 52 83 On request 58 95 On request On request On request IORR..CC-U contactors Power circuit up to 600 V DC acc. to UL / CSA Control circuit 120V 50/60 Hz Description 1SBC104034F0000 IORR..CC-U contactors are used for controlling DC power circuits up to 600 V DC. IORR800-10-CC-U These contactors are designed with: – One N.O. Pole – control circuit: AC operated – 2 NO + 2 NC auxiliary contacts available, as standard For R800 … R2100 contactors, if the breaking current is lower than 50 % of the contactor rating, permanent magnet must be added: see blowout code table. Ordering details UL / CSA General use rating 600 V DC A 800 1000 1300 1700 2000 Number of poles 1 1 1 1 1 Rated con- Auxiliary trol circuit contacts fitted (2) voltage Uc (1) V 50/60 Hz 120V 2 2 120V 2 2 120V 2 2 120V 2 2 120V 2 2 Type Order code Weight 4 pkg (1 pce) IORR800-10-CC-U IORR1000-10-CC-U IORR1400-10-CC-U IORR1700-10-CC-U IORR2100-10-CC-U FPL8616195R2113 FPL8716195R2113 FPL6116195R2113 FPL6216195R2113 FPL6316195R2113 kg 30 31 32 34 37 (1) Other control voltages, please consult us. (2) Other auxiliary contact arrangements, please consult us. R contactor US catalog | 1SXU106047C0201 39 IORR..CC-AMA and IORR..CC-AME contactors Power circuit up to 1500 V DC, with latching Control circuit 120V 50/60 Hz Description 1SBC104044F0000 IORR..CC-AMA and IORR..CC-AME contactors are used for controlling DC power circuits up to 1500 V DC. IORR800-30-CC-AME These contactors are designed with: – magnetic latching, AMA types – mechanical latching, AME types – variable number of poles according to the application – control circuit: AC operated – 2 NO + 2 NC auxiliary contact available for AMA version, as standard – 2 NO + 2 NC auxiliary contacts available for AME version Ordering details IEC DC-1 Rated operational current voltage (3) A V DC 4 DC-3 / DC-5 Rated operational current voltage (3) A V DC Magnetical latching 85 500 68 1000 1500 170 500 125 1000 1500 275 500 205 1000 1500 Mechanical latching 400 500 350 1000 1500 550 500 500 1000 1500 800 750 720 1500 1000 750 720 1500 1250 750 720 1500 1600 750 720 1500 2000 750 720 1500 2300 750 On request 1500 3200 750 On request 1500 3800 750 On request 1500 4500 750 On request 1500 5000 750 On request Number Rated con- Auxiliary Type of poles trol circuit contacts fitted (2) voltage Uc (1) V 50/60 Hz 500 1000 1500 500 1000 1500 500 1000 1500 1 2 3 1 2 3 1 2 3 120V 500 1000 1500 500 1000 1500 600 1000 1500 600 1000 1500 600 1000 1500 600 1000 1500 600 1000 1500 On request 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 1 2 1 2 1 120V On request On request On request On request 120V 120V 120V 120V 120V 120V 120V 120V 120V 120V 120V 120V 120V (1) Other control voltages, please consult us. (2) Other auxiliary contact arrangements, please consult us. (3) Power circuit above 1500 V DC, please consult us. 40 1SXU10607C0201 | R contactor US catalog Order code Weight pkg (1 pce) kg 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 IORR63-10-CC-AMA IORR63-20-CC-AMA IORR63-30-CC-AMA IORR125-10-CC-AMA IORR125-20-CC-AMA IORR125-30-CC-AMA IORR200-10-CC-AMA IORR200-20-CC-AMA IORR200-30-CC-AMA FPL7116136R2123 FPL7116236R2123 On request FPL7416135R2123 FPL7416235R2123 On request FPL7616135R2123 FPL7616235R2123 On request 2.9 3.9 4.9 3.9 5.9 7.9 6.2 9.2 12.2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 IORR400-10-CC-AME IORR400-20-CC-AME IORR400-30-CC-AME IORR500-10-CC-AME IORR500-20-CC-AME IORR500-30-CC-AME IORR800-10-CC-AME IORR800-20-CC-AME IORR800-30-CC-AME IORR1000-10-CC-AME IORR1000-20-CC-AME IORR1000-30-CC-AME IORR1400-10-CC-AME IORR1400-20-CC-AME IORR1400-30-CC-AME IORR1700-10-CC-AME IORR1700-20-CC-AME IORR1700-30-CC-AME IORR2100-10-CC-AME IORR2100-20-CC-AME IORR2100-30-CC-AME IORR2500-10-CC-AME IORR2500-20-CC-AME IORR2500-30-CC-AME IORR3200-10-CC-AME IORR3200-20-CC-AME IORR3200-30-CC-AME IORR3800-10-CC-AME IORR3800-20-CC-AME IORR4500-10-CC-AME IORR4500-20-CC-AME IORR5100-10-CC-AME FPL9416125R2223 FPL9416225R2223 FPL9416325R2223 FPL8316125R2223 FPL8316225R2223 FPL8316325R2223 FPL8616125R2223 FPL8616225R2223 FPL8616325R2223 FPL8716125R2223 FPL8716225R2223 FPL8716325R2223 FPL6116125R2223 FPL6116225R2223 FPL6116325R2223 FPL6216125R2223 FPL6216225R2223 FPL6216325R2223 FPL6316125R2223 FPL6316225R2223 FPL6316325R2223 FPL6716125R2223 FPL6716225R2223 FPL6716325R2223 FPL6516125R2223 FPL6516225R2223 FPL6516325R2223 FPL6616125R2223 FPL6616225R2223 FPL6816125R2223 FPL6816225R2223 FPL6916125R2223 18.4 24.2 30 18.4 24.2 30 40 50 61 40 50 61 42 52 62 43 57 71 46 62 78 On request On request On request On request On request Notes R contactor US catalog | 1SXU106047C0201 41 IORR63..CC … IORR500..CC contactors Technical data Main pole - Utilization characteristics according to IEC AC operated Contactor types Standards Rated operational voltage Ue max. Number of poles Conventional free-air thermal current Ith acc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C With conductor cross-sectional area DC-1 Utilization category, L/R ≤ 1 ms Ie / Rated operational current DC-1 1 pole IORR63..CC IORR125..CC IORR200..CC IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1 1000 V DC (1500 V DC with increased insulation (1)) 1...4 IORR400..CC IORR500..CC 85 A 25 mm² 170 A 70 mm² 275 A 150 mm² 400 A 240 mm² 550 A 400 mm² ≤ 500 V 85 A 170 A 275 A 400 A 550 A ≤ 1000 V ≤ 1500 V (1) 85 A - 170 A - 275 A - 400 A 400 A 550 A 550 A ≤ 1500 V (1) 85 A 170 A 275 A 400 A 550 A ≤ 500 V 68 A 125 A 205 A 350 A 500 A ≤ 1000 V 68 A 125 A 205 A 350 A 500 A ≤ 1500 V (1) 68 A 125 A 205 A 350 A 500 A ≤ 500 V 68 A 125 A 205 A 350 A 500 A ≤ 1000 V 68 A 125 A 205 A 350 A 500 A 68 A 1150 A 680 A 310 A 230 A 120 A 125 A 2250 A 1280 A 680 A 450 A 250 A 205 A 3800 A 2080 A 1040 A 730 A 390 A 350 A 6000 A 3200 A 1600 A 1200 A 600 A 500 A 8400 A 4400 A 2200 A 1680 A 840 A 272 A 272 A 272 A 1300 A 1400 A 1.8 mΩ 120 cycles/h 500 A 500 A 500 A 2400 A 2500 A 1.20 mΩ 820 A 820 A 820 A 4000 A 4500 A 0.60 mΩ 1400 A 1400 A 1400 A 7000 A 8000 A 0.40 mΩ 2000 A 2000 A 2000 A 9000 A 10000 A 0.35 mΩ 2 poles in series 4 3 poles in series DC-3 Utilization category, L/R ≤ 2 ms Ie / Rated operational current DC-3 1 pole 2 poles in series 3 poles in series DC-5 Utilization category, L/R ≤ 7.5 ms Ie / Rated operational current DC-5 1 pole 2 poles in series 3 poles in series Rated short-time withstand current Icw at 40 °C ambient temperature, in free air from a cold state Rated breaking capacity (L/R ≤ 15 ms) Maximum making capacity Dynamical withstand of pole Impedance per pole Maximum electrical switching frequency Mechanical durability Number of operating cycles Maximum switching frequency ≤ 1500 V (1) 1s 10 s 30 s 1 min 15 min 1 pole 500 V 2 poles 1000 V 3 poles 1500 V 5 millions cycles 1200 cycles/h (1) Version with increased insulation for 1000 V < Ue < 1500 V, please consult us. Notes: - The arc switching on DC is more difficult than on AC - For information, typical time constant values are quoted hereafter: non inductive loads such as resistance furnaces: L/R < 1 ms; inductive loads such as shunt motor: L/R < 2 ms; series motor: L/R < 7.5 ms - The addition of a resistor in parallel with an inductive winding helps in the elimination of the arcs - All the poles required for breaking must be connected, in series, between the load and the source polarity not linked to the earth - Connection of the poles in series by the user, according to the above diagrams. The connection of the poles in series helps in the elimination of the arcs - These characteristics are suitable for IOR..CC-AMA and IOR..CC-AME contactor latching versions (except for mechanical durability = 0.2 millions of operating cycles). 42 1SXU10607C0201 | R contactor US catalog IORR800..CC … IORR2100..CC contactors Technical data Main pole - Utilization characteristics according to IEC AC operated Contactor types Standards Rated operational voltage Ue max. Number of poles Conventional free-air thermal current Ith acc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C With conductor cross-sectional area DC-1 Utilization category, L/R ≤ 1 ms Ie / Rated operational current DC-1 1 pole IORR800..CC IORR1000..CC IORR1400..CC IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1 1500 V DC 1...4 IORR1700..CC IORR2100..CC 800 A 500 mm² 1000 A 600 mm² 1300 A 1000 mm² 1700 A 1500 mm² 2000 A 1500 mm² ≤ 750 V 800 A 1000 A 1250 A 1600 A 2000 A ≤ 1000 V ≤ 1500 V 800 A 800 A 1000 A 1000 A 1250 A 1250 A 1600 A 1600 A 2000 A 2000 A ≤ 600 V 720 A 1000 A 1250 A 1600 A 2000 A ≤ 1000 V 720 A 1000 A 1250 A 1600 A 2000 A ≤ 1500 V 720 A 1000 A 1250 A 1600 A 2000 A ≤ 600 V 720 A 1000 A 1250 A 1600 A 2000 A ≤ 1000 V 720 A 1000 A 1250 A 1600 A 2000 A ≤ 1500 V 1s 10 s 30 s 1 min 15 min 720 A 9000 A 6400 A 3200 A 2100 A 1200 A 1000 9000 6400 3200 2100 1200 1250 A 11000 A 9000 A 5000 A 3600 A 1900 A 1600 A 13000 A 11000 A 6000 A 4200 A 2200 A 2000 A 15000 A 12000 A 7000 A 4600 A 2600 A 2880 A 2880 A 2880 A 14000 A 14000 A 0.28 mΩ 120 cycles/h 4000 A 4000 A 4000 A 14000 A 14000 A 0.24 mΩ 5000 A 5000 A 5000 A 19000 A 19000 A 0.18 mΩ 60 cycles/h 6400 A 6400 A 6400 A 21000 A 21000 A 0.12 mΩ 8000 A 8000 A 8000 A 24000 A 24000 A 0.10 mΩ 2 poles in series 4 DC-3 Utilization category, L/R ≤ 2 ms Ie / Rated operational current DC-3 1 pole 2 poles in series 3 poles in series DC-5 Utilization category, L/R ≤ 7.5 ms Ie / Rated operational current DC-5 1 pole 2 poles in series 3 poles in series Rated short-time withstand current Icw at 40 °C ambient temperature, in free air from a cold state Rated breaking capacity (L/R ≤ 15 ms) Maximum making capacity Dynamical withstand of pole Impedance per pole Maximum electrical switching frequency Mechanical durability Number of operating cycles Maximum switching frequency 1 pole 600 V 2 poles 1000 V 3 poles 1500 V 5 millions cycles 1200 cycles/h A A A A A A 2 millions cycles 600 cycles/h Notes: - The arc switching on DC is more difficult than on AC - For information, typical time constant values are quoted hereafter: non inductive loads such as resistance furnaces: L/R < 1 ms; inductive loads such as shunt motor: L/R < 2 ms; series motor: L/R < 7.5 ms - The addition of a resistor in parallel with an inductive winding helps in the elimination of the arcs - All the poles required for breaking must be connected, in series, between the load and the source polarity not linked to the earth - Connection of the poles in series by the user, according to the above diagrams. The connection of the poles in series helps in the elimination of the arcs - These characteristics are suitable for IOR..CC-AME contactor latching versions (except for mechanical durability = 0.2 millions of operating cycles). R contactor US catalog | 1SXU106047C0201 43 IORR2500..CC … IORR5100..CC contactors Technical data Main pole - Utilization characteristics according to IEC AC operated Contactor types Standards Rated operational voltage Ue max. Number of poles Conventional free-air thermal current Ith acc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C With conductor cross-sectional area DC-1 Utilization category, L/R ≤ 1 ms Ie / Rated operational current DC-1 1 pole IORR2500..CC IORR3200..CC IORR3800..CC IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1 1500 V DC 1...4 IORR4500..CC IORR5100..CC 2300 A 2000 mm² 3200 A 3000 mm² 3800 A 3000 mm² 4500 A 4000 mm² 5000 A 4000 mm² ≤ 750 V 2300 A 3200 A 3800 A 4500 A 5000 A ≤ 1000 V ≤ 1500 V 2300 A 2300 A 3200 A 3200 A 3800 A 3800 A 4500 A 4500 A 5000 A 5000 A 21000 A 18000 A 10000 A 7000 A 4000 A 26000 A 26000 A 0.06 mΩ 24000 A 19000 A 11000 A 7500 A 4500 A 29000 A 29000 A 0.05 mΩ 40 cycles/h 28000 A 21000 A 12000 A 8000 A 5000 A 32000 A 32000 A 0.04 mΩ 30000 A 24000 A 13000 A 9000 A 5500 A 32000 A 32000 A 0.03 mΩ 2 poles in series 4 DC-3 Utilization category, L/R ≤ 2 ms Ie / Rated operational current DC-3 For voltage up to 1500 V DC-5 Utilization category, L/R ≤ 7.5 ms Ie / Rated operational current DC-5 For voltage up to 1500 V Rated short-time withstand current Icw at 40 °C ambient temperature, in free air from a cold state Maximum making capacity Dynamical withstand of pole Impedance per pole Maximum electrical switching frequency Mechanical durability Number of operating cycles Maximum switching frequency Please consult us 1s 10 s 30 s 1 min 15 min Please consult us 20000 A 15000 A 8000 A 6000 A 3000 A 24000 A 24000 A 0.09 mΩ 60 cycles/h 2 millions cycles 600 cycles/h 1 million cycles 300 cycles/h Notes: - The arc switching on DC is more difficult than on AC - For information, typical time constant values are quoted hereafter: non inductive loads such as resistance furnaces: L/R < 1 ms; inductive loads such as shunt motor: L/R < 2 ms; series motor: L/R < 7.5 ms - The addition of a resistor in parallel with an inductive winding helps in the elimination of the arcs - All the poles required for breaking must be connected, in series, between the load and the source polarity not linked to the earth - Connection of the poles in series by the user, according to the above diagrams. The connection of the poles in series helps in the elimination of the arcs - These characteristics are suitable for IOR..CC-AME contactor latching versions (except for mechanical durability = 0.2 millions of operating cycles). 44 1SXU10607C0201 | R contactor US catalog Notes R contactor US catalog | 1SXU106047C0201 45 5 46 1SXU10607C0201 | R contactor US catalog Advanced applications N.O. / N.C. main poles combination Presentation 48 Power circuit up to 690 V AC NORR, NORR..MT AC operated 49 Power circuit up to 1500 V DC NORR, NORR..CC AC operated 50 Technical data 51 Power circuit coupling Presentation 54 Power circuit up to 1000 V AC or 1500 V DC LORR AC operated 5 55 Technical data 57 Slip-ring motor control 60 Rotor voltages up to 1500 V AC FORR1000 … FORR3800 AC operated 62 AC operated 63 AC operated 64 AC operated 65 Rotor voltages up to 2500 V AC FORR1000S … FORR2100S Rotor voltages up to 3500 V AC FORR1000NSP … FORR2100NSP Rotor voltages up to 4200 V AC FORR1000SPE … FORR2100SPE Closed transition star-delta starting of three-phase asynchronous motors 66 Field discharge contactors AM-CC-JOR and AMF-CC-JOR 67 Autotransformer starters 68 Type and order code for R contactors 18 R contactor US catalog | 1SXU106047C0201 47 N.O. / N.C. main poles combination NOR contactors Description NOR contactors are built with a combination of N.O. and N.C. poles: – AC switching: NOR..MT up to 690 V AC – DC switching: NOR..CC up to 1500 V DC in standard. – For low current breaking, permanent magnet must be added. 2 NO + 2 NC auxiliary contacts are fitted as standard. For additional auxiliary contacts refer to “Auxiliary contact fitting details.” Example of use : Change-over contactor with 2 N.C. poles + 2 N.O. poles. Block diagrams These contactors are suitable for controlling 2 separate circuits, i.e. 2 loads with 2 separate supplies, or 1 circuit including 2 separate loads with a single supply (diagrams on left column). When the contactor operates there is no mechanical overlapping between the N.O. poles and the N.C. poles: BREAK before MAKE operation. R1 R3 5 7 R2 R4 6 8 R0114D 5 These contactors are not suitable for a reversing starter or star-delta starter, or for controlling a single load from 2 separate supplies. ! 2 N.C. poles + 2 N.O. poles Supply R1 A2 R2 R3 5 R4 6 Load 7 8 Load R0115DG A1 Single supply and 2 separate loads A1 R1 A2 R2 Load The breaking and making capacities of the N.C. poles are identical to those of the N.O. poles. Main supply R3 5 R4 6 7 8 Load R0116DG Back-up supply 2 separate supplies and 2 separate loads 48 Operation The N.O. and N.C. poles are set-up without any mechanical overlap: – as the electro-magnet closes, the N.C. pole(s) BREAK before the N.O. pole(s) MAKE – as the electro-magnet opens, the N.O. pole(s) BREAK before the N.C. pole(s) MAKE. 1SXU10607C0201 | R contactor US catalog Other variants Please consult us for : – NOR..AMA and NOR..AME with latching – JOR types: version with overlapping between N.O. and N.C. main poles. 1SBC104042F0000 NORR, NORE, NORR..MT and NORE..MT contactors Power circuit up to 690 V AC Control circuit 120V 50/60 Hz NORR125-02-MT Description NORR..MT and NORE..MT contactors with N.O. and N.C. main poles are used for controlling AC power circuits up to 690 V AC. NORR400 ... NORR800 and NORE400 ... NORE800 contactors with N.O. and N.C. main poles are used for controlling AC power circuits up to 500 V AC. These contactors are designed with: – variable number of poles according to the application – control circuit: AC or DC operated – 2 NO + 2 NC auxiliary contacts available, as standard. AC operated IEC Rated operationnal current voltage (3) θ ≤ 40 °C AC-1 A V AC 63 690 125 690 200 690 315 500 800 500 690 (1) (2) (3) (4) Number of poles (4) 0 2 3 0 2 3 0 2 3 0 2 3 0 2 3 0 2 3 2 1 1 2 1 1 2 1 1 2 1 1 2 1 1 2 1 1 Rated con- Auxiliary trol circuit contacts fitted (2) voltage Uc (1) V 50/60 Hz 120V 2 2 2 2 2 2 120V 2 2 2 2 2 2 120V 2 2 2 2 2 2 120V 2 2 2 2 2 2 120V 2 2 2 2 2 2 120V 2 2 2 2 2 2 Type Order code Weight pkg (1 pce) NORR63-02-MT NORR63-21-MT NORR63-31-MT NORR125-02-MT NORR125-21-MT NORR125-31-MT NORR200-02-MT NORR200-21-MT NORR200-31-MT NORR400-02 NORR400-21 NORR400-31 NORR800-02 NORR800-21 NORR800-31 NORR800-02-MT NORR800-21-MT NORR800-31-MT FPL7155216R2113 FPL7155516R2113 FPL7155716R2113 FPL7455215R2113 FPL7455515R2113 FPL7455715R2113 FPL7655215R2113 FPL7655515R2113 FPL7655715R2113 FPL9445215R2113 FPL9445515R2113 FPL9445715R2113 FPL8645215R2113 FPL8645515R2113 FPL8645715R2113 FPL8655215R2113 FPL8655515R2113 FPL8655715R2113 5 kg 4.2 3.9 4.9 6.2 8.2 9 9.6 10 12.2 12 15 18 38 48 58 40 51 62 Other control voltages, please consult us. Other auxiliary contact arrangements, please consult us. Power circuit above 690 V AC, please consult us. Other main pole combinations, please consult us. R contactor US catalog | 1SXU106047C0201 49 1SBC104042F0000 NORR, NORE, NORR..CC and NORE..CC contactors Power circuit up to 1500 V DC Control circuit 120V 50/60 Hz NORR125-02-CC Description NORR..CC and NORE..CC contactors with N.O. and N.C. main poles are used for controlling DC power circuits up to 1500 V DC. NORR and NORE400 up to 440 V DC. These contactors are designed with: – variable number of poles according to the application – control circuit: AC or DC operated – 2 NO + 2 NC auxiliary contacts available, as standard. AC operated Number of poles (4) IEC Rated operationnal current voltage (3) DC-1 DC-3 DC-5 A 63 A 63 125 125 200 200 315 315 800 720 5 V DC 1000 1000 1000 1000 1000 1000 440 440 1000 1500 V DC 500 1000 500 500 500 1000 500 500 500 1000 500 500 220 440 220 220 500 1000 500 500 0 0 2 3 0 0 2 3 0 0 2 3 0 0 2 3 0 0 2 3 1 2 1 1 1 2 1 1 1 2 1 1 1 2 1 1 1 2 1 1 Rated con- Auxiliary Type trol circuit contacts fitted (2) voltage Uc (1) V 50/60 Hz 120V 120V 120V 120V 120V (1) Other control voltages, please consult us. (2) Other auxiliary contact arrangements, please consult us. (3) Please consult us for power circuit above: - 1000 V DC for ratings 63…500 A - 1500 V DC for ratings 800 A. (4) Other main pole combinations, please consult us. 50 1SXU10607C0201 | R contactor US catalog 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 NORR63-01-CC NORR63-02-CC NORR63-21-CC NORR63-31-CC NORR125-01-CC NORR125-02-CC NORR125-21-CC NORR125-31-CC NORR200-01-CC NORR200-02-CC NORR200-21-CC NORR200-31-CC NORR400-01 NORR400-02 NORR400-21 NORR400-31 NORR800-01-CC NORR800-02-CC NORR800-21-CC NORR800-31-CC Order code Weight pkg (1 pce) FPL7146116R2113 FPL7146216R2113 FPL7146516R2113 FPL7146716R2113 FPL7446115R2113 FPL7446215R2113 FPL7446515R2113 FPL7446715R2113 FPL7646115R2113 FPL7646215R2113 FPL7646515R2113 FPL7646715R2113 FPL9445115R2113 FPL9445215R2113 FPL9445515R2113 FPL9445715R2113 FPL8646115R2113 FPL8646215R2113 FPL8646515R2113 FPL8646715R2113 kg 3.2 4.2 3.9 4.9 4.2 6.2 8.2 9 6.6 9.6 10 12.2 9 12 15 18 28.6 40 51 62 NORR63..MT … NORR800..MT contactors Technical data Main pole - Utilization characteristics according to IEC AC operated Contactor types Standards Rated operational voltage Ue max. Rated frequency (without de-rating) Number of poles Conventional free-air thermal current Ith acc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C With conductor cross-sectional area AC-1 Utilization category For air temperature close to contactor θ ≤ 40 °C Ie / Rated operational current AC-1 Ue max. ≤ 690 V, 50/60 Hz θ ≤ 55 °C With conductor cross-sectional area Rated making capacity AC-1 Rated breaking capacity AC-1 AC-3 Utilization category For air temperature close to contactor θ ≤ 55 °C Ie / Max. rated operational current AC-3 NORR63..MT NORR125..MT NORR200..MT NORR800..MT IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1 690 V 25…60 Hz (for > 60...400 Hz please consult us) 2…4 500 V 63 A 16 mm² 125 A 50 mm² 63 A 125 A 56 A 110 A θ ≤ 70 °C 50 A 100 A 16 mm² 50 mm² 1.5 x Ie AC-1 acc. to IEC 60947-4-1 1.5 x Ie AC-1 acc. to IEC 60947-4-1 NORR400 NORR800 200 A 95 mm² 800 A 500 mm² 315 A 185 mm² 800 A 500 mm² 200 A 180 A 160 A 95 mm² 800 710 640 500 315 280 250 185 800 710 640 500 A A A mm² A A A mm² A A A mm² 5 M 3 690 V Please consult us Short-circuit protection device for contactors without thermal overload relay - Motor protection excluded Ue ≤ 1000 V AC - gG type fuse 80 A Ue ≤ 1000 V AC - L type fuse 1 s 850 A Rated short-time withstand current Icw 10 s 500 A at 40 °C ambient temperature, 30 s 250 A in free air from a cold state 1 min 230 A 15 min 120 A Impedance per pole 1.8 mΩ AC-1 300 cycles/h Maximum electrical switching frequency Mechanical durability Number of operating cycles 3 millions cycles Maximum switching frequency 1200 cycles/h 160 A 2250 A 1280 A 680 A 450 A 250 A 1.20 mΩ 250 A 3800 A 2080 A 1040 A 730 A 390 A 0.60 mΩ 1000 A 7500 A 6000 A 3000 A 2000 A 1200 A 0.28 mΩ 630 A 5000 A 2500 A 1250 A 870 A 460 A 0.40 mΩ 300 cycles/h 1000 A 7500 A 6000 A 3000 A 2000 A 1200 A 0.18 mΩ 1 million cycles 3 millions 1 million cycles cycles 1200 cycles/h Note: These characteristics are suitable for NOR..MT-AMA and NOR..MT-AME contactors with latching versions (except for mechanical durability = 0.2 millions of operating cycles). R contactor US catalog | 1SXU106047C0201 51 NORR63..CC … NORR800..CC contactors Technical data Main pole - Utilization characteristics according to IEC AC operated Contactor types Standards Rated operational voltage Ue max. Number of poles Conventional free-air thermal current Ith acc. to IEC 60947-4-1, open contactors, θ ≤ 40 °C With conductor cross-sectional area DC-1 Utilization category, L/R ≤ 1 ms Ie / Rated operational current DC-1 1 pole 2 poles in series NORR63..CC NORR125..CC NORR200..CC IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1 1000 V DC (1500 V DC with increased insulation (1)) 1…4 NORR800..CC NORR400 63 A 16 mm² 125 A 50 mm² 200 A 95 mm² 800 A 500 mm² 315 A 185 mm² ≤ 220 V ≤ 500 V ≤ 440 V ≤ 1000 V ≤ 1500 V 63 A 63 A - 125 A 125 A - 200 A 200 A - 800 A 800 A 800 A 315 A 315 A - ≤ 1500 V (1) 63 A 125 A 200 A 800 A - ≤ 220 V ≤ 500 V 63 A 125 A 200 A 720 A 315 A - ≤ 440 V ≤ 1000 V 63 A 125 A 200 A 720 A 315 A - ≤ 1500 V (1) 63 A 125 A 200 A 720 A - ≤ 220 V ≤ 500 V 63 A 125 A 200 A 720 A 315 A - ≤ 440 V ≤ 1000 V 63 A 125 A 200 A 720 A 315 A - 63 A 850 A 500 A 250 A 170 A 90 A 125 A 1700 A 900 A 450 A 310 A 180 A 200 A 3100 A 1600 A 800 A 560 A 300 A 720 A 9000 A 6400 A 3200 A 2100 A 1200 A 5000 A 2500 A 1250 A 870 A 460 A 252 A 252 A 252 A 1.8 mΩ 120 cycles/h 500 A 500 A 500 A 1.20 mΩ 800 A 800 A 800 A 0.60 mΩ 2880 A 2880 A 2880 A 0.18 mΩ 1260 A (220 V) 1260 A (440 V) 0.40 mΩ 120 cycles/h 1 million cycles 3 million cycles 1200 cycles/h 440 V DC 3 poles in series 5 DC-3 Utilization category, L/R ≤ 2 ms Ie / Rated operational current DC-3 1 pole 2 poles in series 3 poles in series DC-5 Utilization category, L/R ≤ 7.5 ms Ie / Rated operational current DC-5 1 pole 2 poles in series 3 poles in series Rated short-time withstand current Icw at 40 °C ambient temperature, in free air from a cold state Rated breaking capacity (L/R ≤ 15 ms) Impedance per pole Maximum electrical switching frequency Mechanical durability Number of operating cycles Maximum switching frequency ≤ 1500 V (1) 1s 10 s 30 s 1 min 15 min 1 pole 500 V 2 poles 1000 V 3 poles 1500 V 3 millions cycles 1200 cycles/h (1) NOR63 ... NOR200: version with increased insulation for 1000 V < Ue < 1500 V, please consult us. Notes: - The arc switching on DC is more difficult than on AC - For selecting a contactor, it is essential to determine the current, the voltage, an the L/R time constant of the controlled load - For information, typical time constant values are quoted hereafter: non inductive loads such as resistance furnaces: L/R < 1 ms; inductive loads such as shunt motor: L/R < 2 ms; series motor: L/R < 7.5 ms - The addition of a resistor in parallel with an inductive winding helps in the elimination of the arcs - All the poles required for breaking must be connected, in series, between the load and the source polarity not linked to the earth - Connection of the poles in series by the user, according to the above diagrams. The connection of the poles in series helps in the elimination of the arcs - These characteristics are suitable for NOR..CC-AMA and NOR..CC-AME contactor latching versions (except for mechanical durability = 0.2 millions of operating cycles). 52 1SXU10607C0201 | R contactor US catalog Notes R contactor US catalog | 1SXU106047C0201 53 Power circuit coupling LOR couplers Description LOR couplers are built without blowout coil and arc chutes. They are not suitable for breaking on-load at voltages above 24 V AC or DC. – AC switching up to 1000 V AC – DC switching up to: - 1000 V DC for R85 … R550 - 1500 V DC for R800 … R5100 For other voltages, please consult us. 2 NO + 2 NC auxiliary contacts are fitted as standard. For additional auxiliary contact, refer to "Auxiliary contact fitting details". Example of use – Automatic short-circuiting of the starting resistances of a slip-ring or DC motors without the possibility of opening on-load – Electrolytic installations and electro-plating plants – Induction furnaces (please consult us). 5 Other variants: Please consult us for: – LOR couplers with N.C. poles – LOR..AMA and LOR..AME couplers with latching. 54 1SXU10607C0201 | R contactor US catalog 1SBC104043F0000 LORR couplers Power circuit up to 1000 V AC or 1500 V DC Control circuit 120V 50/60 Hz LORR550-20 Description LORR are used for controlling: – AC power circuits up to 1000 V AC – DC power circuits up to: - 1000 V DC for ratings 85…550 A - 1500 V DC for ratings 800…5100 A They are not suitable for breaking on-load at voltages above 24 V AC or DC. These contactors are designed with: – variable number of poles according to the application – control circuit: AC operated – 2 NO + 2 NC auxiliary contacts available, as standard. Ordering details Conventional Rated thermal current operational voltage lth (θ ≤ 40 °C) A 90 V AC 1000 V DC (3) 1000 185 1000 1000 300 1000 1000 420 1000 1000 630 1000 1000 1100 1000 1400 1000 1700 1000 2100 1000 2500 1000 3200 1000 3800 1000 4500 1000 5100 1000 1000 1500 1500 1500 1000 1500 1500 1500 1000 1500 1500 1500 1000 1500 1500 1500 1000 1500 1500 1500 1000 1500 1500 1500 1000 1500 1500 1500 1000 1500 1500 1000 1500 Number Rated control of poles circuit voltage Uc (1) 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 1 2 V 50/60 Hz 120V 120V 120V 120V 120V 120V 120V 120V 120V 120V 120V 120V 120V 120V Auxiliary Type contacts fitted (2) 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 LORR85-10 LORR85-20 LORR85-30 LORR85-40 LORR170-10 LORR170-20 LORR170-30 LORR170-40 LORR260-10 LORR260-20 LORR260-30 LORR260-40 LORR400-10 LORR400-20 LORR400-30 LORR400-40 LORR550-10 LORR550-20 LORR550-30 LORR550-40 LORR800-10 LORR800-20 LORR800-30 LORR800-40 LORR1400-10 LORR1400-20 LORR1400-30 LORR1400-40 LORR1700-10 LORR1700-20 LORR1700-30 LORR1700-40 LORR2100-10 LORR2100-20 LORR2100-30 LORR2100-40 LORR2500-10 LORR2500-20 LORR2500-30 LORR2500-40 LORR3200-10 LORR3200-20 LORR3200-30 LORR3200-40 LORR3800-10 LORR3800-20 LORR3800-30 LORR3800-40 LORR4500-10 LORR4500-20 LORR4500-30 LORR5100-10 LORR5100-20 Order code Weight pkg (1 pce) FPL7235110R2113 FPL7235210R2113 FPL7235310R2113 FPL7235410R2113 FPL7535110R2113 FPL7535210R2113 FPL7535310R2113 FPL7535410R2113 FPL7835110R2113 FPL7835210R2113 FPL7835310R2113 FPL7835410R2113 FPL9435110R2113 FPL9435210R2113 FPL9435310R2113 FPL9435410R2113 FPL8435110R2113 FPL8435210R2113 FPL8435310R2113 FPL8435410R2113 FPL8635110R2113 FPL8635210R2113 FPL8635310R2113 FPL8635410R2113 FPL6135110R2113 FPL6135210R2113 FPL6135310R2113 FPL6135410R2113 FPL6235110R2113 FPL6235210R2113 FPL6235310R2113 FPL6235410R2113 FPL6335110R2113 FPL6335210R2113 FPL6335310R2113 FPL6335410R2113 FPL6735110R2113 FPL6735210R2113 FPL6735310R2113 FPL6735410R2113 FPL6535110R2113 FPL6535210R2113 FPL6535310R2113 FPL6535001R2113 FPL6635110R2113 FPL6635210R2113 FPL6635002R2113 FPL6635003R2113 FPL6835110R2113 FPL6835210R2113 FPL6835001R2113 FPL6935110R2113 FPL6935001R2113 5 kg 2.6 3 3.4 3.8 3.2 4.1 5 5.9 4.7 5.9 7.1 8.3 11.4 14.7 18 21.3 11.4 14.7 18 21.3 29 34 42 54 30 36 44 56 34 42 50 66 36 44 52 68 On request On request On request On request On request (1) Other control voltages, please consult us. (2) Other auxiliary contact arrangements, please consult us. (3) Please consult us for power circuit above 1000 V AC or 1500 V DC. R contactor US catalog | 1SXU106047C0201 55 LORR85 ... LORR550 couplers Technical data Main pole - Utilization characteristics according to IEC AC operated Couplers types Standards Rated operational voltage Ue max. Rated frequency (without derating) Number of poles Conventional free-air thermal current Ith acc. to IEC 60947-4-1, open couplers, θ ≤ 40 °C With conductor cross-sectional area AC-1 / DC-1 Utilization category For air temperature close to couplers θ ≤ 40 °C Ie / Rated operational current AC-1 / DC-1 θ ≤ 55 °C Ue max. ≤ 690 V, 50/60 Hz LORR85 LORR170 LORR260 IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1 1000 V 25…60 Hz (for > 60…400 Hz please contact us) 1…4 LORR400 LORR550 90 A 35 mm² 420 A 300 mm² 630 A 400 mm² 420 370 330 300 630 570 500 400 185 A 95 mm² 300 A 185 mm² 90 A 185 A 300 A 82 A 170 A 270 A θ ≤ 70 °C 72 A 150 A 240 A 35 mm² 95 mm² 185 mm² 1000 V max. 1.5 x Ie / AC-1 or DC-1 acc. to IEC 60947-4-1 24 V max. 1.5 x Ie / AC-1 or DC-1 acc. to IEC 60947-4-1 With conductor cross-sectional area Rated making capacity AC-1 / DC-1 Rated breaking capacity AC-1 / DC-1 Short-circuit protection device for couplers without thermal overload relay - Motor protection excluded Ue ≤ 1000 V AC - gG type fuse 100 A Ue ≤ 1000 V AC - L type fuse 1 s 1150 A Rated short-time withstand current Icw 10 s 680 A at 40 °C ambient temperature, 30 s 310 A in free air from a cold state 1 min 230 A 15 min 120 A Impedance per pole 1.80 mΩ AC-1 300 cycles/h Maximum electrical switching frequency Mechanical durability Number of operating cycles 5 millions cycles Maximum switching frequency 1200 cycles/h 5 200 A 2250 A 1200 A 680 A 450 A 250 A 1.20 mΩ 315 A 3800 A 1920 A 1040 A 730 A 390 A 0.60 mΩ A A A mm² 500 A 6000 A 2960 A 1480 A 1100 A 600 A 0.40 mΩ Note: - Technical data applicable for N.O. main poles. For N.C. main poles, please consult us. - These characteristics are suitable for LOR..AMA and LOR..AME contactor versions (except for mechanical durability = 0.2 millions of operating cycles). 56 1SXU10607C0201 | R contactor US catalog A A A mm² 700 A 8400 A 4400 A 2200 A 1680 A 840 A 0.35 mΩ LORR800 ... LORR5100 couplers Technical data Main pole - Utilization characteristics according to IEC AC operated Couplers types Standards Rated operational voltage Ue max. Rated frequency (without de-rating) Number of poles Conventional free-air thermal current Ith acc. to IEC 60947-4-1, open couplers, θ ≤ 40 °C With conductor cross-sectional area AC-1 / DC-1 Utilization category For air temperature close to couplers θ ≤ 40 °C Ie / Rated operational current AC-1 / DC-1 θ ≤ 55 °C Ue max. ≤ 690 V, 50/60 Hz LORR800 LORR1400 LORR1700 LORR2100 LORR2500 LORR3200 LORR3800 LORR4500 LORR5100 IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1 1000 V 25…60 Hz (for > 60…400 Hz please consult us) 1…4 1100 A 800 mm² 1400 A 1700 A 2100 A 2500 A 3200 A 3800 A 4500 A 5100 A 1000 mm² 1500 mm² 1500 mm² 2000 mm² 3000 mm² 3000 mm² 4000 mm² 4000 mm² 1100 A 1400 A 1700 A 2100 A 1000 A 1230 A 1500 A 1840 A θ ≤ 70 °C 900 A 1030 A 1250 A 1540 A 800 mm² 1000 mm² 1500 mm² 1500 mm² 1000 V max. 1.5 x Ie / AC-1 or DC-1 acc. to IEC 60947-4-1 24 V max. 1.5 x Ie / AC-1 or DC-1 acc. to IEC 60947-4-1 With conductor cross-sectional area Rated making capacity AC-1 / DC-1 Rated breaking capacity AC-1 / DC-1 Short-circuit protection device for couplers without thermal overload relay - Motor protection excluded Ue ≤ 1000 V AC - Circuit breaker 1250 A 1600 A 1 s 9000 A 11000 A Rated short-time withstand current Icw 10 s 8000 A at 40 °C ambient temperature, 9000 A 30 s 4000 A 5000 A in free air from a cold state 1 min 3000 A 3700 A 15 min 1600 A 2000 A Impedance per pole 0.18 mΩ 0.10 mΩ AC-1 300 cycles/h 150 cycles/h Maximum electrical switching frequency Mechanical durability Number of operating cycles 5 millions cycles Maximum switching frequency 1200 cycles/h 2500 2200 1830 2000 A A A mm² 3200 2800 2350 3000 A A A mm² 3800 3330 2780 3000 A A A mm² 4500 3950 3300 4000 A A A mm² 5100 4470 3740 4000 A A A mm² 5 2000 A 2500 A 13000 A 15000 A 11000 A 12200 A 6000 A 7000 A 4400 A 5000 A 2400 A 2800 A 0.090 mΩ 0.080 mΩ 120 cycles/h 20000 A 21000 A 15000 A 18000 A 8000 A 10000 A 6000 A 7000 A 3000 A 4000 A 0.05 mΩ 0.045 mΩ 60 cycles/h 24000 A 28000 A 19000 A 21000 A 11000 A 12000 A 7500 A 8000 A 4500 A 5000 A 0.04 mΩ 0.03 mΩ 40 cycles/h 2 millions cycles 600 cycles/h 1 million cycles 300 cycles/h 29000 A 22000 A 13000 A 8500 A 5500 A 0.027 mΩ Note: - Technical data applicable for N.O. main poles. For N.C. main poles, please consult us. - These characteristics are suitable for LOR..AME contactor versions (except for mechanical durability = 0.2 millions of operating cycles). R contactor US catalog | 1SXU106047C0201 57 Notes 58 1SXU10607C0201 | R contactor US catalog Slip-ring motor control With rheostats Application Three kinds of contactors are used to control three-phase slip-ring motors: the stator contactor, the acceleration contactor(s), and the rotor short-circuit contactor. Example of a three-stroke starter (star (Y) connection diagram) Stator contactor Rotor short-circuit contactor Acceleration contactor R2 R1 M 3 5 The starting resistances should be star (Y) or V connected acc. to the following wiring diagrams. Contactors have to be selected accordingly. V Stator contactor The standard R contactor selection is based on the motor rated current acc. to the AC-2 utilization category, as well as on the rated operational voltage and the on-load factor. Acceleration contactor and rotor short-circuit contactor FOR contactor selection is based on the contactor rated operational current Ie acc. to the AC-1 utilization category. At the time of slip-ring motor starting and as soon as the motor nominal speed is reached, these contactors are used for the short-circuiting of the rotor current limitation starting resistances (e.g. vapor-liquid rheostats). These contactors are derived from the standard R contactors and are available in 2, 3, 4 or 6-pole versions acc. to the applicable connection diagram required (Y, V). They can control rotor currents up to 3800 A and rotor voltages up to 4200 V (with increased insulation) acc. to the IEC 60947-4-1 standard requirements. For rotor voltages ≥ 4200 V, please consult us. Although the breaking of the rotor circuit is normally carried out in "off-load" conditions, the contactors are equipped with blowout devices and can occasionally break "on-load". Ordering details, dimensions : please consult us. The LOR couplers may be used for applications where equipment is breaking in "Off-load" conditions only. R contactor US catalog | 1SXU106047C0201 59 Slip-ring motor control With variable frequency drive Application This variant is used to start a slip-ring motor which will be then controlled by a variable frequency drive. (1) Stator contactor (4) Rotor inverter contactor 5 M 3 (2) Starter coupling contactor (3) Rotor short-circuit contactor Rheostat Description A liquid rheostat is used to start and accelerate the motor after closing of the starter coupling contactor (2) and then the stator contactor (1). When the nominal speed is reached, the rotor short-circuit contactor (3) closes. Then the rotor inverter contactor closes (4) and the starter coupling contactor (2) opens. The speed of the motor is controlled by the variable frequency drive. FOR contactors are suitable for starter coupling (2), rotor short-circuiting (3) and rotor inverter (4) contactor. IOR contactors must be used for stator contactor (1). 60 1SXU10607C0201 | R contactor US catalog FORR1000 … FORR3800 contactors Rotor voltages up to 1500 V AC Main pole - Utilization characteristics according to IEC (Y and V connection diagram) AC operated Contactor types Rated rotor operational voltage Uer Rated frequency (without de-rating) Conventional free-air thermal current Ith acc. to IEC 60947-4-1, θ ≤ 40 °C With conductor cross-sectional area Rated rotor operational current Ier For air temperature close to contactor θ ≤ 40 °C θ ≤ 55 °C θ ≤ 70 °C With conductor cross-sectional area Maximum making capacity Maximum breaking capacity at cos φ = 0.80 and 1000 V Rated short-time withstand current Icw at 40 °C ambient temperature, in free air from a cold state Impedance per pole Maximum electrical switching frequency Mechanical durability Number of operating cycles Max. switching frequency 1s 10 s 30 s 1 min 15 min FORR1000 FORR1400 FORR1700 1500 V 0.1...60 Hz (for > 60 Hz consult us) FORR2100 FORR2500 FORR3200 FORR3800 1000 A 600 mm² 1400 A 1000 mm² 1700 A 1500 mm² 2100 A 2000 mm² 2500 A 2000 mm² 3200 A 3000 mm² 3800 A 3000 mm² 1000 A 930 A 800 A 600 mm² 14000 A 1400 A 1180 A 1000 A 1000 mm² 19000 A 1700 A 1450 A 1250 A 1500 mm² 21000 A 2100 A 1750 A 1500 A 2000 mm² 24000 A 2500 A 2200 A 1830 A 2000 mm² 24000 A 3200 A 2800 A 2350 A 3000 mm² 26000 A 3800 A 3200 A 2780 A 3000 mm² 29000 A 1500 A 9000 A 8000 A 4000 A 3000 A 1600 A 0.18 mΩ 120 cycles/h 2100 A 11000 A 9000 A 5000 A 3700 A 2000 A 0.10 mΩ 2600 A 13000 A 11000 A 6000 A 4400 A 2400 A 0.09 mΩ 3200 A 15000 A 12200 A 7000 A 5000 A 2800 A 0.08 mΩ 3800 A 20000 A 15000 A 8000 A 6000 A 3000 A 0.05 mΩ 4800 A 21000 A 18000 A 10000 A 7000 A 4000 A 0.045 mΩ 5700 A 24000 A 19000 A 11000 A 7500 A 4500 A 0.04 mΩ 5 millions cycles 600 cycles/h 2 millions cycles 5 Note: Altitude ≥ 2000 m, dimension drawings: please consult us. - Consult us for order codes. R contactor US catalog | 1SXU106047C0201 61 FORR1000S … FORR2100S contactors Rotor voltages up to 2500 V AC Main pole - Utilization characteristics according to IEC (Y and V connection diagram) AC operated Contactor types Rated rotor operational voltage Uer Rated frequency (without de-rating) Conventional free-air thermal current Ith acc. to IEC 60947-4-1, θ ≤ 40 °C With conductor cross-sectional area Rated rotor operational current Ier For air temperature close to contactor θ ≤ 40 °C θ ≤ 55 °C θ ≤ 70 °C With conductor cross-sectional area Maximum making capacity Maximum breaking capacity at cos φ = 0.80 and 1000 V Rated short-time withstand current Icw at 40 °C ambient temperature, in free air from a cold state 5 Impedance per pole Maximum electrical switching frequency Mechanical durability Number of operating cycles Max. switching frequency 1s 10 s 30 s 1 min 15 min FORR1000S FORR1400S FORR1700S FORR2100S FORR2500S FORR3200S FORR3800S 2500 V 0.1...60 Hz (for > 60 Hz consult us) 1000 A 600 mm² 1400 A 1000 mm² 1700 A 1500 mm² 2100 A 2000 mm² 2500 A 2000 mm² 3200 A 3000 mm² 3800 A 3000 mm² 1000 A 930 A 800 A 600 mm² 14000 A 1400 A 1180 A 1000 A 1000 mm² 19000 A 1700 A 1450 A 1250 A 1500 mm² 21000 A 2100 A 1750 A 1500 A 2000 mm² 24000 A 2500 A 2200 A 1830 A 2000 mm² 24000 A 3200 A 2800 A 2350 A 3000 mm² 26000 A 3800 A 3200 A 2780 A 3000 mm² 29000 A 1500 A 9000 A 8000 A 4000 A 3000 A 1600 A 0.18 mΩ 120 cycles/h 2100 A 11000 A 9000 A 5000 A 3700 A 2000 A 0.10 mΩ 2600 A 13000 A 11000 A 6000 A 4400 A 2400 A 0.09 mΩ 3200 A 15000 A 12200 A 7000 A 5000 A 2800 A 0.08 mΩ 3800 A 20000 A 15000 A 8000 A 6000 A 3000 A 0.05 mΩ 4800 A 21000 A 18000 A 10000 A 7000 A 4000 A 0.045 mΩ 5700 A 24000 A 19000 A 11000 A 7500 A 4500 A 0.04 mΩ 5 millions cycles 600 cycles/h 2 millions cycles Note: Altitude ≥ 2000 m, dimension drawings: please consult us. - Consult us for order codes. 62 1SXU10607C0201 | R contactor US catalog FORR1000NSP … FORR2100NSP contactors Rotor voltages up to 3500 V AC Main pole - Utilization characteristics according to IEC (Y and V connection diagram) AC operated Contactor types Rated rotor operational voltage Uer Rated frequency (without de-rating) Conventional free-air thermal current Ith acc. to IEC 60947-4-1, θ ≤ 40 °C With conductor cross-sectional area Rated rotor operational current Ier For air temperature close to contactor θ ≤ 40 °C θ ≤ 55 °C θ ≤ 70 °C With conductor cross-sectional area Maximum making capacity Maximum breaking capacity at cos φ = 0.80 and 1000 V Rated short-time withstand current Icw at 40 °C ambient temperature, in free air from a cold state Impedance per pole Maximum electrical switching frequency Mechanical durability Number of operating cycles Max. switching frequency 1s 10 s 30 s 1 min 15 min FORR1000NSP FORR1400NSP FORR1700NSP FORR2100NSP FORR2500NSP FORR3200NSP FORR3800NSP 3500 V 0.1...60 Hz (for > 60 Hz consult us) 1000 A 600 mm² 1400 A 1000 mm² 1700 A 1500 mm² 2100 A 2000 mm² 2500 A 2000 mm² 3200 A 3000 mm² 3800 A 3000 mm² 1000 A 930 A 800 A 600 mm² 14000 A 1400 A 1180 A 1000 A 1000 mm² 19000 A 1700 A 1450 A 1250 A 1500 mm² 21000 A 2100 A 1750 A 1500 A 2000 mm² 24000 A 2500 A 2200 A 1830 A 2000 mm² 24000 A 3200 A 2800 A 2350 A 3000 mm² 26000 A 3800 A 3200 A 2780 A 3000 mm² 29000 A 1500 A 9000 A 8000 A 4000 A 3000 A 1600 A 0.18 mΩ 120 cycles/h 2100 A 11000 A 9000 A 5000 A 3700 A 2000 A 0.10 mΩ 2600 A 13000 A 11000 A 6000 A 4400 A 2400 A 0.09 mΩ 3200 A 15000 A 12200 A 7000 A 5000 A 2800 A 0.08 mΩ 3800 A 20000 A 15000 A 8000 A 6000 A 3000 A 0.05 mΩ 4800 A 21000 A 18000 A 10000 A 7000 A 4000 A 0.045 mΩ 5700 A 24000 A 19000 A 11000 A 7500 A 4500 A 0.04 mΩ 5 millions cycles 600 cycles/h 2 millions cycles 5 Note: Altitude ≥ 2000 m, dimension drawings: please consult us. - Consult us for order codes. R contactor US catalog | 1SXU106047C0201 63 FORR1000SPE … FORR2100SPE contactors Rotor voltages up to 4200 V AC Main pole - Utilization characteristics according to IEC (Y only connection diagram) AC operated Contactor types Rated rotor operational voltage Uer Rated frequency (without de-rating) Conventional free-air thermal current Ith acc. to IEC 60947-4-1, θ ≤ 40 °C With conductor cross-sectional area Rated rotor operational current Ier For air temperature close to contactor θ ≤ 40 °C θ ≤ 55 °C θ ≤ 70 °C With conductor cross-sectional area Maximum making capacity Maximum breaking capacity at cos φ = 0.80 and 1000 V Rated short-time withstand current Icw at 40 °C ambient temperature, in free air from a cold state 5 Impedance per pole Maximum electrical switching frequency Mechanical durability Number of operating cycles Max. switching frequency 1s 10 s 30 s 1 min 15 min FORR1000SPE FORR1400SPE FORR1700SPE FORR2100SPE FORR2500SPE FORR3200SPE FORR3800SPE 4200 V 0.1...60 Hz (for > 60 Hz consult us) 1000 A 600 mm² 1400 A 1000 mm² 1700 A 1500 mm² 2100 A 2000 mm² 2500 A 2000 mm² 3200 A 3000 mm² 3800 A 3000 mm² 1000 A 930 A 800 A 600 mm² 14000 A 1400 A 1180 A 1000 A 1000 mm² 19000 A 1700 A 1450 A 1250 A 1500 mm² 21000 A 2100 A 1750 A 1500 A 2000 mm² 24000 A 2500 A 2200 A 1830 A 2000 mm² 24000 A 3200 A 2800 A 2350 A 3000 mm² 26000 A 3800 A 3200 A 2780 A 3000 mm² 29000 A 1500 A 9000 A 8000 A 4000 A 3000 A 1600 A 0.18 mΩ 120 cycles/h 2100 A 11000 A 9000 A 5000 A 3700 A 2000 A 0.10 mΩ 2600 A 13000 A 11000 A 6000 A 4400 A 2400 A 0.09 mΩ 3200 A 15000 A 12200 A 7000 A 5000 A 2800 A 0.08 mΩ 3800 A 20000 A 15000 A 8000 A 6000 A 3000 A 0.05 mΩ 4800 A 21000 A 18000 A 10000 A 7000 A 4000 A 0.045 mΩ 5700 A 24000 A 19000 A 11000 A 7500 A 4500 A 0.04 mΩ 5 millions cycles 600 cycles/h 2 millions cycles Note: - Uer > 4200 V AC, please consult us. - Altitude ≥ 2000 m, dimension drawings: please consult us. - Consult us for order codes. 64 1SXU10607C0201 | R contactor US catalog Closed transition star-delta starting of three-phase asynchronous motors R contactor selection Application R contactors can be used for closed transition star-delta starting of three-phase asynchronous motors up to 1300 kW. Description This starting method, mainly used for large motor powers, prevents the speed drop during the "star-delta" transition time and maintains the resulting current peak at a relatively low value. For this purpose the extra KM4 transition contactor closes first before the KM2 star contactor opens. When the KM4 contactor closes, the motor windings are automatically delta connected, via resistances, to compensate the lack of current during the transition time. Thus the motor speed remains basically the same. The final delta connection step is then achieved by the KM3 delta contactor closing which switches-off the coil supply to the KM4 transition contactor. As in the basic star-delta starting mode, the closed transition star-delta starting mode is restricted to low resistive torque machines. It is advisable, especially for big masses of inertia, to observe that the connection is made in acc. to the clockwise or anticlockwise rotation direction, as indicated in the block diagram shown below, in order to prevent damages due to torque throbs. 5 Equipment sizing – KM1 main contactor and KM3 delta contactor: rating = 0.58 x In for both contactors – KM2 star contactor: compared with a star contactor that would be used for a basic open transition star-delta starter the present KM2 star contactor has to be over-rated as it is intended to break the star current (0.34 x In) and the transition current too. – KM4 transition contactor: the rating is based on the calculation of the short permissible current duration (Icw). The value of the current flow is about 1.5 x In and the current flow duration < 100 ms. A block type contactor in the AF series can be selected for this step. – Transition resistances: empiric value, generally as follows, R (Ω) = 0.4 x Ue In Watt dissipation values for the transition resistances: Ue2 1200 x R - for 30 cycles/h max. P (W) = Ue 2 500 x R - for 12 cycles/h max. P (W) = Block Diagram 1 3 5 2 4 6 KM4 1 3 5 2 4 6 KM2 / (Y) 1 3 5 2 4 6 L1 L2 L3 1 3 5 2 4 6 KM1 / (L) KM3 / ( ) 1 3 5 2 4 6 R W2 KM1: Line contactor KM2: Star contactor KM3: Delta contactor KM4: Closed transition contactor R: Transition resistances W1 V2 V1 U2 U1 W2 W1 V2 V1 U2 U1 R contactor US catalog | 1SXU106047C0201 65 AM-CC-JOR and AMF-CC-JOR field discharge contactors Power circuit up to 2250 V DC, R63 ... R4500 Application Field discharge contactors (or field circuit breakers) are used to control the field winding of synchronous machines or exciter machines. In case of disturbances, the contactors ensure a definite disconnection from the supply source and the subsequent discharge of the energy stored in the machine magnetic circuit via a discharge resistor. Diagram Supply AMF-CC-JORE 800-21 Discharge resistor 5 Field discharge contactor Field winding Description These contactors are designed with: – 2 or 3 N.O. main poles with blowout devices, suitable for 2250 V DC max. operational voltage and circuit time constant L/R ≤ 15 ms – 1 N.C. main pole, without blowout device, named "discharge pole" and set MAKE before BREAK with regard to the N.O. main poles. Electro-magnet AM-CC-JOR and AMF-CC-JOR field discharge contactors are equipped with a latching device: – magnetic latch for R63 ... R200 – mechanical latch for R550 ... R4500. AC or DC control circuit. The AMF-CC-JOR type is equipped with 2 tripping coils (double de-latching control). Auxiliary contacts – AM-CC: 5 auxiliary contacts as standard (3 N.O. + 2 N.C.) – AMF-CC: 4 auxiliary contacts as standard (2 N.O. + 2 N.C.) – Up to 16 auxiliary contacts max. on request. 66 1SXU10607C0201 | R contactor US catalog Autotransformer starters General An autotransformer starter allows to start a squirrel-cage motor with a reduced starting current due to the reduced voltage within the accelerating duration. At the contrary of the star-delta wiring, this autotransformer starting method needs three wires and three terminals on the motor. At the starting period, the motor is wired to the autotransformer taps: the "KM3" star contactor and the "KM2" autotransformer contactor are closed, the motor is under reduced voltage. Consequently, the torque is reduced as the square of the applied voltage. The auto-transformers are generally equipped of three taps at each phase in order to adapt the starting parameters to the field requirements. When the motor reaches 80...95% of its nominal speed, the star contactor opens. Then, the "KM1" line contactor is making and the autotransformer contactor is opening. This starting process is done without any network interruption. Electrical distribution KM2 KM1 T1 Autotransformer KM3 5 Selection table (Id starting current / In nominal current < 8 - Acceleration time < 20 s - 30 cycles / h max.) Motor ratings 50/60 Hz 440 V kW 500 560 630 710 800 900 1000 Contactors KM1 Line IOR..800 IOR..1400 IOR..1400 IOR..1400 IOR..1700 IOR..2100 IOR..2100 KM2 Autotransformer taps 90 % 80 % IOR..800 IOR..500..MT IOR..800 IOR..500..MT IOR..800 IOR..800 IOR..1400 IOR..800 IOR..1400 IOR..800 IOR..1700 IOR..1400..MT IOR..1700 IOR..1400..MT 70 % IOR..400..MT IOR..500..MT IOR..500..MT IOR..500..MT IOR..800 IOR..800 IOR..800 60 % IOR..400..MT IOR..400..MT IOR..400..MT IOR..400..MT IOR..500..MT IOR..500..MT IOR..500..MT KM3 Autotransformer taps 90 % 80 % IOR..200..MT IOR..400..MT IOR..200..MT IOR..400..MT IOR..200..MT IOR..400..MT IOR..200..MT IOR..500..MT IOR..400..MT IOR..500..MT IOR..400..MT IOR..800 IOR..400..MT IOR..800 R contactor US catalog | 1SXU106047C0201 60-70 % IOR..500..MT IOR..500..MT IOR..800 IOR..800 IOR..800 IOR..1400 IOR..1400 67 6 68 1SXU10607C0201 | R contactor US catalog Advanced applications Technical data 70 6 R contactor US catalog | 1SXU106047C0201 69 R contactors Technical data Types NORR63..MT NORR63..CC NORR125..MT NORR125..CC NORR200..MT NORR200..CC NORR400 NORR800..MT NORR800..CC NORR800 Magnet system characteristics Coil operating limits acc. to IEC 60947-4-1 AC control voltage 50/60 Hz Rated control circuit voltage Uc Coil consumption At θ ≤ 55 °C 0.85…1.1 x Uc Average pull-in value Average holding value Drop-out voltage Operating time (average values for Uc) For N.O. poles of the NORR Between coil energization and N.C. contact opening Between coil de-energization and N.C. contact closing For N.C. poles of the NORR Between coil energization and N.O. contact closing Between coil de-energization and N.O. contact opening 6 Types 24…550 V AC 290 VA 25 VA 20...75 % of Uc 460 VA 45 VA 410 VA 45 VA 540 VA 65 VA 610 VA 55 VA 30 ms 20 ms 30 ms 20 ms 40 ms 20 ms 60 ms 50 ms 100 ms 55 ms 27 ms 23 ms 27 ms 23 ms 37 ms 23 ms 55 ms 28 ms 85 ms 60 ms NORR63..MT NORR63..CC NORR125..MT NORR125..CC NORR200..MT NORR200..CC NORR400 NORR800..MT NORR800..CC NORR800 2 X M6 2 x M6 2 x M8 2 x M12 4 x M12 Mounting characteristics Fixing by screws (not supplied) Connecting characteristics Main terminals Connection capacity (min. ... max.) Main conductors (poles) Terminal plates width Terminal screw (not supplied) Drilling holes (without thread) Auxiliary conductors (built-in auxiliary terminals + coil terminals) Rigid solid Flexible without ferrule Tightening torque Coil terminals Built-in auxiliary terminals Screw terminals Main terminals Coil terminals Built-in auxiliary terminals 70 Terminal plates for lugs or bars 16 mm 2 x M6 - 1 or 2 x 1 or 2 x 20 mm 2 x M6 - 1...2.5 mm² 1...2.5 mm² 1.5 Nm 1.5 Nm Screws and bolts M4 with cable clamps M4 with cable clamps 1SXU10607C0201 | R contactor US catalog 25 mm 2 x M8 - 30 mm 1 x ø13 mm 48 mm 2 x ø13 mm R contactors Technical data General technical data Contactor types Standards Rated insulation voltage Ui acc. to IEC 60947-4-1 and EN 60947-4-1 R63 ... R500 R800 ... R5100 Rated impulse withstand voltage Uimp. Ambient air temperature close to contactor Operation Storage Climatic withstand Maximum operating altitude (without de-rating) IOR, LOR, NOR contactors IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1 1000 V AC or 1000 V DC (1500 V DC with increased insulation) 1000 V AC or 1500 V DC 8 kV -20...+70 °C -20...+80 °C Standard version for industrial environment and atmospheres 2000 m Mounting characteristics and condition for use Contactor types Mounting positions IOR, LOR, NOR contactors Position 1 (horizontal bar) 6 Mounting distances Maximum angle of inclination, in any direction : ±22° 30' See "Dimensions" R contactor US catalog | 1SXU106047C0201 71 R contactors Technical data Types IORR63..MT IORR63..CC LORR85 IORR125..MT IORR125..CC LORR170 IORR200..MT IORR200..CC LORR260 IORR400..MT IORR400..CC LORR400 IORR500..MT IORR500..CC LORR550 Magnet system characteristics Coil operating limits acc. to IEC 60947-4-1 AC control voltage 50/60 Hz Rated control circuit voltage Uc Coil consumption At θ ≤ 55 °C 0.85…1.1 x Uc Average pull-in value Average holding value Drop-out voltage Operating time (average values for Uc) Between coil energization and N.O. contact closing Between coil de-energization and N.O. contact opening Types 6 24…550 V AC 290 VA 25 VA 20...75 % of Uc 460 VA 45 VA 410 VA 45 VA 540 VA 65 VA 540 VA 65 VA 30 ms 20 ms 30 ms 20 ms 40 ms 20 ms 60 ms 50 ms 60 ms 50 ms IORR63..MT IORR63..CC LORR85 IORR125..MT IORR125..CC LORR170 IORR200..MT IORR200..CC LORR260 IORR400..MT IORR400..CC LORR400 IORR500..MT IORR500..CC LORR550 2 x M6 2 x M6 2 x M8 2 x M12 2 x M12 Mounting characteristics Fixing by screws (not supplied) Connecting characteristics Main terminals Connection capacity (min. ... max.) Main conductors (poles) Terminal plates width Terminal screw (not supplied) Drilling holes (without thread) Auxiliary conductors (built-in auxiliary terminals + coil terminals) Rigid solid Flexible without ferrule Tightening torque Coil terminals Built-in auxiliary terminals Screw terminals Main terminals Coil terminals Built-in auxiliary terminals 72 Terminal plates for lugs or bars 16 mm M6 x 20 - 1 or 2 x 1 or 2 x 20 mm M8 x 20 - 1...2.5 mm² 1...2.5 mm² 1.5 Nm 1.5 Nm Screws and bolts M4 with cable clamps M4 with cable clamps 1SXU10607C0201 | R contactor US catalog 25 mm M10 x 25 - 30 mm 1 x ø13 mm 30 mm 1 x ø13 mm R contactors Technical data Types IORR800 LORR800 IORR800..MT IORR800..CC IORR1000 IORR1000..CC FORR1000 IORR1400 LORR1400 IORR1400..MT IORR1400..CC FORR1400 IORR1700 LORR1700 IORR1700..MT IORR1700..CC FORR1700 IORR2100 LORR2100 IORR2100..MT IORR2100..CC FORR2100 Magnet system characteristics Coil operating limits acc. to IEC 60947-4-1 AC control voltage 50/60 Hz Rated control circuit voltage Uc Coil consumption At θ ≤ 55 °C 0.85…1.1 x Uc Average pull-in value Average holding value 24…550 V AC 610 VA 2 4 2 4 55 VA and 3 poles: 610 VA 2...4 poles: 925 VA poles: 925 VA and 3 poles: 55 VA 2...4 poles: 130 VA poles: 130 VA Drop-out voltage Operating time (average values for Uc) Between coil energization and N.O. contact closing Between coil de-energization and N.O. contact opening 20...75 % of Uc 100 ms 55 ms 100 ms 55 ms 100 ms 55 ms 90 ms 40 ms 90 ms 30 ms Types IORR800 LORR800 IORR800..MT IORR800..CC IORR1000 IORR1400 LORR1400 IORR1400..MT IORR1400..CC FORR1400 IORR1700 LORR1700 IORR1700..MT IORR1700..CC FORR1700 IORR2100 LORR2100 IORR2100..MT IORR2100..CC FORR2100 IORR1000..CC FORR1000 6 Mounting characteristics Fixing by screws (not supplied) 4 x M12 Connecting characteristics Main terminals Connection capacity (min. ... max.) Main conductors (poles) Terminal plates width Drilling holes (without thread) Auxiliary conductors (built-in auxiliary terminals + coil terminals) Rigid solid Flexible without ferrule Tightening torque Coil terminals Built-in auxiliary terminals Screw terminals Main terminals Coil terminals Built-in auxiliary terminals Terminal plates for lugs or bars 48 mm 2 x ø13 mm 1 or 2 x 1 or 2 x 48 mm 2 x ø13 mm 60 mm 2 x ø13 mm 80 mm 4 x ø11 mm 100 mm 4 x ø11 mm 1...2.5 mm² 1...2.5 mm² 1.5 Nm 1.5 Nm Screws and bolts M4 with cable clamps M4 with cable clamps R contactor US catalog | 1SXU106047C0201 73 R contactors Technical data Types IORR2500 LORR2500 IORR2500..MT IORR2500..CC FORR2500 IORR3200 LORR3200 IORR3200..MT IORR3200..CC FORR3200 IORR3800 LORR3800 IORR3800..MT IORR3800..CC FORR3800 IORR4500 LORR4500 IORR4500..MT IORR4500..CC IORR5100 LORR5100 IORR5100..MT IORR5100..CC 1...3 poles: 925 VA 1...3 poles: 130 VA 1 and 2 poles: 925 VA 1 and 2 poles: 130 VA 1 and 2 poles: 925 VA 1 and 2 poles: 130 VA 1 pole: 925 VA 1 pole: 130 VA IORR2500 LORR2500 IORR2500..MT IORR2500..CC FORR2500 IORR3200 LORR3200 IORR3200..MT IORR3200..CC FORR3200 IORR3800 LORR3800 IORR3800..MT IORR3800..CC FORR3800 IORR4500 LORR4500 IORR4500..MT IORR4500..CC IORR5100 LORR5100 IORR5100..MT IORR5100..CC 4 x M12 4 or 6 x M12 Magnet system characteristics Coil operating limits acc. to IEC 60947-4-1 AC control voltage 50/60 Hz Rated control circuit voltage Uc Coil consumption At θ ≤ 55 °C 0.85…1.1 x Uc 48…550 V AC 1...4 poles: 925 VA Average holding value 1...4 poles: 130 VA 20...75 % of Uc Average pull-in value Drop-out voltage Operating time (average values for Uc) Between coil energization and N.O. contact closing Between coil de-energization and N.O. contact opening 6 Types - Mounting characteristics Fixing by screws (not supplied) Connecting characteristics Main terminals Connection capacity (min. ... max.) Main conductors (poles) Terminal plates width Drilling holes (without thread) Auxiliary conductors (built-in auxiliary terminals + coil terminals) Rigid solid Flexible without ferrule Tightening torque Coil terminals Built-in auxiliary terminals Screw terminals Main terminals Coil terminals Built-in auxiliary terminals 74 Terminal plates for lugs or bars 150 mm 8 x ø9 mm 1 or 2 x 1 or 2 x 180 mm 8 x ø13 mm 1...2.5 mm² 1...2.5 mm² 1.5 Nm 1.5 Nm Screws and bolts M4 with cable clamps M4 with cable clamps 1SXU10607C0201 | R contactor US catalog 220 mm 8 x ø13 mm 280 mm 12 x ø11 mm 340 mm 14 x ø13 mm Notes R contactor US catalog | 1SXU106047C0201 75 7 76 1SXU10607C0201 | R contactor US catalog Accessories and spare parts Auxiliary contacts Auxiliary contact blocks CA12 78 Auxiliary contacts CA15 78 Technical data 79 Main poles Contact sets 80 Arcing horns 80 Equipotential connections 81 Arc chutes 81 Control circuits Surge suppressors 82 Rectifiers 82 Magnet circuits 82 7 Mechanical interlock units 83 Mounting feet - Shaft extensions 84 R contactor US catalog | 1SXU106047C0201 77 Auxiliary contacts Auxiliary contact blocks type CA12 1SBC373832F0301 Description CA12-1 CA12 auxiliary contact blocks 2 or 4-pole are mounted on a support bracket, above the electro-magnet. The R contactors type R and RE can be equipped with: – 1 or 2 x 2-pole blocks – 1 x 2-pole block + 1 x 4-pole blocks. The R contactors type RR can be equipped with 1 or 2 x 2-pole blocks. Ordering details For R contactors type R, RE, RR (RC excluded) Auxiliary contacts Type Order code Pkg qty Weight (1 pce) kg Auxiliary contact blocks 63 ... 550 1 2 2 3 4 1 0 2 1 0 Support bracket 63 … 260 315 … 550 7 CA12-1 CA12-2 CA12-11 CA12-12 CA12-22 FPTN410004R0001 FPTN410005R0001 FPTN410013R0001 FPTN410016R0001 FPTN410012R0001 1 1 1 1 1 0.050 0.050 0.090 0.090 0.090 Support bracket Support bracket FPTN410056R0001 FPTN410056R0002 1 1 0.060 0.060 1SBC104054F0014 Auxiliary contacts type CA15 Description CA15 auxiliary contacts are mounted on a mounting kit, on the frame. Ordering details For R contactors type R, RE, RR, RC CA15-F Auxiliary Type contacts Order code Pkg qty Weight (1 pce) kg 1SBC104053F0014 Auxiliary contact with screw terminals 63 ... 5100 CA15-O Auxiliary contact for railway 63 ... 5100 Mounting kit 63 … 170, 315 … 550, auxiliary frame ≥ 800 200 … 260 Main frame ≥ 800 1 0 0 1 CA15-F CA15-O FPTN410008R0004 FPTN410007R0006 1 1 0.070 0.070 1 0 0 1 CA15-F CA15-O FPTN210382R0003 FPTN210382R0004 1 1 0.070 0.070 universal mounting kit Mounting kit Mounting kit FPTN410054R0016 1 On request FPTN410054R0017 FPTN410213R0006 1 1 Special auxiliary contact blocks Please contact your local sales organization (order code of R contactor needed). 78 1SXU10607C0201 | R contactor US catalog Auxiliary contact blocks Technical data CA auxiliary contact blocks Types Rated operational voltage Ue max. Rated frequency (without de-rating) Conventional free-air thermal current Ith acc. to IEC 60947-4-1, open couplers, θ ≤ 40 °C Ie / Rated operational current AC-15 acc. to IEC 60947-5-1 24-48 V 50/60 Hz 110-127 V 50/60 Hz 220-240 V 50/60 Hz 380-440 V 50/60 Hz 500-600 V 50/60 Hz Making capacity acc. to IEC 60947-5-1 Breaking capacity acc. to IEC 60947-5-1 Ie / Rated operational current DC-13 acc. to IEC 60947-5-1 Short-circuit protection device gG type fuse 24 V DC 48 V DC 72 V DC 110-125 V DC 220-250 V DC CA12 690 V 25...400 Hz CA15 12 A 15 A 8A 8A 5A 3A 2A 10 x Ie / AC-15 10 x Ie / AC-15 10 A 10 A 6A 3.5 A 2.5 A 6A 2.8 A 1A 0.55 A 0.3 A 10 A 16 A 7 R contactor US catalog | 1SXU106047C0201 79 Main poles 1SBC388134F0302NB Contacts sets for N.O. or N.C. main poles Description The contact sets include 1 fixed contact, 1 moving contact, 1 arcing horn (according to table below) and screws. The quantities needed are defined per ratings as follow: – 1 set per pole for R63….R800, R1000, R1400, R1700, R2100 – 2 sets per pole for R1250, R1500, R2500, R3200, R3800 – 3 sets per pole for R2000, R4500, R5100 – 4 sets per pole for R3150 – 5 sets per pole for R4000. Ordering details 7 For R contactors type Order code Pkg qty Weight (1 pce) kg Contact set with arcing horn IOR, NOR, JOR, FOR 63, 85 125, 170 200, 260 315, 400 (1), 420 400 (2), 500, 550, 630 FPTN410389R0001 FPTN410389R0002 FPTN410389R0003 FPTN410389R0004 FPTN410389R0005 1 set 1 set 1 set 1 set 1 set 0.050 0.150 0.250 0.400 0.480 Contact set without arcing horn LOR 85 170 260 420 400, 550 IOR, NOR, JOR, FOR, LOR 800, 1000, 1250, 1500, 2000, 3150, 4000 1400, 2500 1700, 2100, 3200, 3800, 4500, 5100 FPTN410390R0001 FPTN410390R0002 FPTN410390R0003 FPTN410390R0004 FPTN410390R0005 FPTN410391R0001 FPTN410503R0001 FPTN410506R0001 1 set 1 set 1 set 1 set 1 set 1 set 1 set 1 set 0.040 0.090 0.180 0.250 0.470 0.520 0.520 0.830 Weight (1 pce) kg 0.200 0.200 0.280 (1) For NOR and JOR types, NC poles (2) For IOR, NOR and JOR types, NO poles Arcing horns for N.O. or N.C. main poles 1SBC104033F0014 Ordering details 80 For R contactors type IOR, NOR, JOR, FOR Order code Pkg qty 800, 1000, 1250, 1500, 2000, 3150, 4000 1400, 2500 1700, 2100, 3200, 3800, 4500, 5100 FPTN410446R0001 FPTN410446R0001 FPTN410508R0001 1 1 1 1SXU10607C0201 | R contactor US catalog Main poles Equipotential connections 1SBC104032F0014 Description Equipotential connections must be ordered separately for ratings ≥ 800 A. Ordering details For R contactors type IOR, NOR, JOR and FOR Type Order code Pkg qty 800 ... 5100 800 ... 4000 NO poles NC poles FPTN410176R0006 FPTN410176R0007 1 1 Weight (1 pce) kg 0.500 0.530 Arc chutes Description De-ion arc chutes replace basic arc chutes except for 315 and 420 A ratings. 1SBC387943F0302 Ordering details For R contactors type IOR, NOR, JOR and FOR Type 63, 85 125, 170 200, 260 315, 400 (1),420 400 (2), 500, 550 800, 1000, 1250, 1500, 2000, 3150, 4000 1400, 2500 1700, 2100, 3200, 3800, 4500, 5100 De-ion arc chute De-ion arc chute De-ion arc chute Basic arc chute De-ion arc chute De-ion arc chute De-ion arc chute De-ion arc chute Order code FPTN401938R0002 FPTN401939R0002 FPTN401940R0002 FPTN401936R0002 FPTN401941R0002 FPTN410067R0002 FPTN410067R0002 FPTN410507R0001 Pkg qty 1 1 1 1 1 1 1 1 Weight (1 pce) kg 0.470 0.930 1.360 1.300 3.600 2.570 2.570 3.150 7 (1) For NOR and JOR types, NC poles (2) For IOR, NOR and JOR types, NO poles Pressure springs, insulated supports, complete poles and other spare parts Please contact your local sales organization (order code for R contactor needed). R contactor US catalog | 1SXU106047C0201 81 Control circuits Surge suppressors for contactor coils 1SBC104030F0014 Ordering details For R contactors type IOR, NOR , JOR, LOR and FOR Rated control circuit Type voltage Uc V AC DC ● 24...60 – RV-R1/60 ● – RV-R1/133 60...133 ● 110...250 – RV-R1/250 ● – RV-R1/440 250...440 ● – RV-R1/660 440...660 Order code Pkg qty Weight (1 pce) FPTN410463R6001 FPTN410463R6002 FPTN410463R6003 FPTN410463R6004 FPTN410463R6005 1 1 1 1 1 kg 0.050 0.050 0.050 0.050 0.050 For R contactors type IORR, NORR, JORR, LORR and FORR Rated control circuit voltage Uc Order code Pkg qty Weight (1 pce) 63 ... 5100 < 440 V AC TRE2614501 1 kg 0.050 ≥ 440 V AC TRE2720806 1 0.050 63 ... 5100 Rectifiers 1SBC104029F0014 Ordering details 7 Complete control circuit kit Including: – 1 coil – 1 economy resistor – 1 surge suppressor – 1 rectifier For complete kit, please contact your local sales organization (order code of R contactor needed). Magnet circuits Ordering details For R contactors type IORR, NORR, JORR, LORR, and FORR IORE, NORE, JORE, LORE, and FORE Order code Pkg qty 63, 85 125, 170 200, 260 400 ... 630 ≥ 800 FPTN410437R0001 FPTN410438R0001 FPTN410439R0001 FPTN410441R0001 FPTN410200R0006 1 1 1 1 1 For tripping electro-magnet circuit AME or AM(F)-CC > 800 A: use 63, 85 A electro-magnet circuit. For IOR and IOR..AMA versions, please consult your local sales organization (order code of R contactor needed). Coils, economy resistors and other specific parts Please contact your local sales organization (order code of R contactor needed). 82 1SXU10607C0201 | R contactor US catalog Weight (1 pce) kg 1.500 1.500 1.500 2.500 8.000 Mechanical interlock units Description The VM mechanical interlock units are designed for the interlocking of two R contactors of the same rating. The mounting between 2 contactors of a same rating doesn't affect their fixing centers or their overall dimensions. 1SBC388162F0302 Ordering details VM For R contactors type IOR, NOR , JOR, LOR and FOR Rating IOR..-CC, IOR..-MT, NOR..-CC, NOR..-MT, LOR IOR..-CC, IOR..-MT, NOR..400, LOR IOR…, LOR…800, NOR…800, FOR…1000 IOR…-CC, IOR…-MT IOR, LOR, FOR IOR…-CC, IOR…-MT Type Order code Pkg qty 63 125 200 400 ... 500 Fixing center mm 220 260 320 520 VM21/24 VM25 VM27 VM15-SP FPL7101403R0001 FPL7401404R0001 FPL8001401R0001 FPL8301401R0002 1 1 1 1 Weight (1 pce) kg 0.140 0.180 0.260 0.500 800 ... 1000 520 VM16 FPL8601401R0001 1 0.600 VM17/18 FPL8801401R0001 1 0.700 VM19 FPL9001401R0001 1 0.800 800 … 1000 640 1400, 1700, 2100 640 1400, 1700, 2100 680 Note: For special versions, please consult us: - interlocking between contactors with N.O. + N.C. poles or with latching - interlocking between 2 contactors of different ratings - interlocking between 3 contactors. 7 R contactor US catalog | 1SXU106047C0201 83 Mounting feet - Shaft extensions Mounting feet Description 1SBC104030F0014 When the contactors are to be fitted on a back plate the mounting feet provide an increased clearance behind the contactor for easier cabling. Two pieces are required for one contactor. Ordering details For R contactors Drilling for bar fixing Ø 63 ... 170 200, 260 400, 500, 550 mm 6.2 8.2 12.5 Fixing centres for vertical wall mounting mm 85 / 100...110 85 / 100...110 110...120 Type Order code Pkg qty Weight (2 pce) 4NMW1009 4NMW1039 4NMW1041 FPL7108201P0001 FPL7608201P0001 FPL8308201P0001 2 2 2 kg 0.060 0.060 0.320 Main dimensions mm 2 x ø 6.5 ø 8.5 ø 6.2* ø 8.2* ø 10.5* ø 12.5* 85 7 100 ... 110 01041 20 x 6.5 110 ... 120 54 1SBC104029F0014 4NMW1009/1039 22 x 8.5 40 22 50 * 4 NMW 1040 : ø = 10.5 * 4 NMW 1041 : ø = 12.5 R0112D * 4 NMW 1009 : ø = 6.2 * 4 NMW 1039 : ø = 8.2 R0111D 15 Shaft extensions Description For 3 or 4 pole reversing or changeover pairs built with two contactors of different ratings, vertically mounted above one another. Fitting on the shaft of the contactor having the smaller frame size. Ordering details For R contactors Type Order code Pkg qty 63 ... 170 - FPTN410111R0001 1 Weight (1 pce) kg (1) 200 ... 420 - FPTN410111R0002 1 (1) 400, 500, 550 - FPTN410111R0003 1 (1) (1) On request. 84 1SXU10607C0201 | R contactor US catalog Notes R contactor US catalog | 1SXU106047C0201 85 8 86 1SXU10607C0201 | R contactor US catalog Terminal marking and wiring diagrams Terminal marking and positioning R63 ... R500 88 R800 ... R5100 89 Wiring diagrams R contactors and couplers Control by 2 impulse pushbuttons and hold-in contact 90 Control by switch 90 R magnetically latched contactors - Contactors and couplers Control by 2 impulse pushbuttons 91 Control by switch 92 8 R contactor US catalog | 1SXU106047C0201 87 R contactors Terminal marking and positioning R63 ... R500 (the main poles in variable number) Main poles The L.H.S. main pole is marked 1-2, the following poles are marked 3-4, 5-6, etc CA12 auxiliary contact blocks Coil 3 2 1 8 CAOVE contact for electrical interlocking CA15 auxiliary contact blocks CA15-OR contact for economy resistor insertion Main poles Coil CAOVE contact CARB contact CA15-OR contact CA12 auxiliary contacts Block No 3 N.O. main poles are respectively marked 1-2, 3-4, 5-6, 7-8 For N.C. main poles the letter R precedes the figures AC coil: the terminals are marked A1 and A2 DC coil: the terminals are marked A1 (-) and A2 (+) N.C. contact, adjustable, intended for electrical interlocking. Terminal marking: 21-22 N.O. contact, intended for "hold-in" function. Terminal marking: 13-14 N.C. contact, factory wired. It is intended for insertion of economy resistor. Terminal marking: 15-16 1 NO + 1 NC 2 NO 2 NO + 2 NC 3 NO + 1 NC 4 NO 3 NO + 3 NC 4 NO + 2 NC Block No 2 Block No 1 CA15 extra auxiliary contacts CA15-F (N.O.) or CA15-O (N.C.) CARB contacts for "hold-in" function 43 31 44 32 No "n" ..3 43 33 44 34 No 8 173 6 NO 71 83 73 83 73 83 73 84 72 84 74 84 74 84 74 63 51 63 53 63 53 63 51 63 51 63 53 63 53 64 52 64 54 64 54 64 52 64 52 64 54 64 54 43 31 43 31 43 33 43 31 43 31 43 31 43 33 44 32 44 32 44 34 44 32 44 32 44 32 44 34 No 7 163 No 6 153 No 5 143 No 4 133 No 3 123 No 2 113 No 1 103 ..4 174 164 154 144 134 124 114 104 ..1 171 161 151 141 131 121 111 101 ..2 172 162 152 142 132 122 112 102 The CA15 auxiliary contacts are fitted from the right on the contactor frame according to this marking. 88 5 NO + 1 NC 83 1SXU10607C0201 | R contactor US catalog R contactors Terminal marking and positioning R800 ... R5100 (the main poles in variable number, can be distributed on both sides of the electro-magnet) Main poles The L.H.S. main pole is marked 1-2, the following poles are marked 3-4, 5-6, etc 4 3 2 1 CA15 auxiliary contact blocks mounted on auxiliary frame Position of the CA15 starting from the right 8 CA15 auxiliary contact blocks mounted on main frame Coil Main poles N.O. main poles are respectively marked 1-2, 3-4, 5-6, 7-8 For N.C. main poles the letter R precedes the figures Coil AC coil: the terminals are marked A1 and A2 DC coil: the terminals are marked A1 (-) and A2 (+) CA15 auxiliary contact No 1 CA15-O (N.C.) contact intended for electrical interlocking. Terminal marking: 21-22 No 2 CA15-F (N.O.) contact intended for "hold-in" function. Terminal marking: 13-14 No 3 CA15-OR (N.C.). This contact is factory wired. It is intended for insertion of economy resistor. Terminal marking: 15-16 No 11 No 10 No 9 No 8 No 7 No 6 No 5 CA15 extra auxiliary contacts No "n" 173 163 153 143 133 123 113 CA15-F (N.O.) ..3 or CA15-O (N.C.) No 4 103 ..4 174 164 154 144 134 124 114 104 ..1 171 161 151 141 131 121 111 101 ..2 172 162 152 142 132 122 112 102 The CA15 auxiliary contacts are fitted from the right, first on the auxiliary frame and next on the main frame of the contactor, according to this marking. R contactor US catalog | 1SXU106047C0201 89 R contactors and couplers Wiring diagrams Control by 2 impulse pushbuttons and hold-in contact AC operated 13 KM I 0 14 16 Re KM 15 A1 + – KM A2 IORR, IORR-MT, IORR-CC, NORR-MT, NORR-CC, LORR 8 Control by switch AC operated I 16 Re KM 15 A1 + – KM A2 IORR, IORR-MT, IORR-CC, NORR-MT, NORR-CC, LORR Note: remove the factory wired strap 14-16 90 1SXU10607C0201 | R contactor US catalog R magnetically latched contactors Contactors and couplers Wiring diagrams Control by 2 impulse pushbuttons AC operated AC operated Control voltage Uc ≤ 110 V AC Control voltage Uc > 110 V AC 63 53 KM 64 63 53 64 54 KM 0 54 0 I I Rad A1 + A2 – KM – 85 86 IORR-CC-AMA, IORR-MT-AMA, NORR-CC-AMA, NORR-MT-AMA, LORR-AMA A1 75 + KM 76 A2 – KM – 85 75 KM 86 76 8 IORR-CC-AMA, IORR-MT-AMA, NORR-CC-AMA, NORR-MT-AMA, LORR-AMA R contactor US catalog | 1SXU106047C0201 91 R mechanically latched contactors Contactors and couplers Wiring diagrams Control by switch AC operated 9 1 1/L1 3/L2 5/L3 7/L4 4/T2 6/T3 8/T4 KM = Closing coil KL = Tripping coil KA1 = Contactor relay KA2 = Timed contactor relay Re = Economy resistor KA1 I 2/T1 3 2 12 Supply between 9 and 10 Closing between 1 and 3 Tripping between 1 and 2 KM 11 A2 A2 KA2 A1 KA1 A1 A1 58 KA2 KL A2 16 + – A2 15 KM 57 A1 KM 14 Re KM 13 10 IORR-AME, IORR-MT-AME, IORR-CC-AME, NORR-CC-AME, NORR-MT-AME, LORR-AME 8 92 1SXU10607C0201 | R contactor US catalog Notes R contactor US catalog | 1SXU106047C0201 93 9 94 1SXU10607C0201 | R contactor US catalog Main dimensions IORR and LORR types R800 … R2100 96 R2500 … R5100 98 IORR..MT and IORR..CC types R63 … R500 100 R800 … R2100 102 R2500 … R5100 104 IORR..AME and LORR..AME types R800 … R2100 106 R2500 … R5100 108 IORR..MT-AMA … IOR..MT-AMA and IORR..CC-AMA … IOR..CC-AMA types R63 ... R200 110 IORR..MT-AME and IORR..CC-AME types R400 ... R500 112 R800 … R2100 114 R2500 … R5100 116 9 NORR..MT and NORR..CC types R63 … R200 118 LORR type R85 … R550 120 R contactor US catalog | 1SXU106047C0201 95 IORR and LORR types R800 … R2100 Main dimensions mm 50 F IORR D 60 LORR D1 D2 LORR types poles are not equipped with arc chutes LORR I = 0 200 IORR I I1 180 200 IORR M LORR M1 CA15 H CA15 N ø A B D3 B 40 F IORR Y 50 LORR Y1 Terminal plate details 48 11.5 25 60 11.5 17.5 25 100 80 17.5 20 40 25 20 2 x ø13 R800 4 x ø11 2 x ø13 R1400 Terminal plate thickness: top terminal plates = 10 mm, bottom terminal plates = 12 mm 96 25 4 x ø11 2 x ø13 R1000 30 25 12.5 25 12.5 25 12.5 9 50 15 11.5 15 25 30 48 11.5 1SXU10607C0201 | R contactor US catalog R1700 R2100 IORR and LORR types R800 … R2100 Contactor types Number Fixing of poles holes Fixing dimensions F R800 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 245 345 385 245 345 385 285 385 540 300 445 540 300 445 540 R1000 R1400 R1700 R2100 Fixing - 4 x ø13 4 x ø13 4 x ø13 4 x ø13 4 x ø13 Dimensions - Dimensions A 60 60 60 60 60 60 85 85 85 85 85 85 85 85 85 B 90 70 90 70 110 120 140 120 140 120 Clearing distances - D 325 325 325 325 325 325 325 325 325 325 325 325 325 325 325 D1 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 D2 75 75 75 75 75 75 75 75 75 75 75 75 75 75 75 D3 77 77 77 77 77 77 77 77 77 77 77 77 77 77 77 H 70 70 70 70 70 70 70 70 70 84 84 84 84 84 84 I 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 I1 98 98 98 98 98 98 98 98 98 112 112 112 112 112 112 M 158 158 158 158 158 158 228 228 228 258 258 258 258 258 258 M1 115 115 115 115 115 115 165 165 165 165 165 165 165 165 165 N 85 85 85 85 85 85 100 100 100 125 125 125 125 125 125 Y 345 345 345 345 345 345 400 400 400 425 425 425 425 425 425 Y1 280 280 280 280 280 280 280 280 280 280 280 280 280 280 280 Connecting 9 R contactor US catalog | 1SXU106047C0201 97 IORR and LORR types R2500 … R5100 Main dimensions mm 50 F IORR D 60 LORR D1 D2 LORR types poles are not equipped with arc chutes LORR I = 0 200 IORR I I1 180 200 IORR M LORR M1 CA15 H CA15 N ø A B D3 B 40 F IORR Y 50 LORR Y1 Fig 1 = right electro-magnet (see table in the following page) 50 F 60 200 M 9 180 CA15 CA15 N ø A B 40 A1 F Fig 2 = central electro-magnet (see table in the following page) 220 180 30 150 30 30 40 35 30 30 50 50 50 35 20 30 40 30 45 45 15 20 30 40 R2500 R3200 Terminal plate thickness for R2500 ... R5100: top and bottom terminal plates = 10 mm 98 8 x ø13 8 x ø13 8 x ø9 1SXU10607C0201 | R contactor US catalog R3800 IORR and LORR types R2500 … R5100 Contactor types Number Fixing of poles holes Fixing dimension F R2500 1 2 3 1 2 3 1 2 1 2 1 385 635 950 445 760 950 445 760 540 950 540 R3200 R3800 R4500 R5100 Fixing - 4 x ø13 4 x ø13 4 x ø13 4 x ø13 4 x ø13 Dimensions - Dimensions A 130 135 135 150 135 135 160 145 185 185 210 A1 135 135 135 145 180 - Clearing distances - B 220 - D 325 325 325 325 325 325 325 325 325 325 325 D1 260 260 260 260 260 260 260 260 260 260 260 D2 85 85 85 99 99 99 99 99 99 99 99 D3 87 87 87 87 87 87 87 87 87 87 87 H 135 135 135 174 174 174 174 174 174 174 174 I 108 108 108 108 108 108 108 108 108 108 108 I1 161 161 161 202 202 202 202 202 202 202 202 40 N 152 152 152 215 215 215 215 215 215 215 215 Y 425 425 425 450 450 450 450 450 450 450 465 Y1 280 280 280 280 280 280 280 280 280 280 280 Fig 1 1 2 1 2 2 1 2 1 2 1 340 40 40 40 20 50 50 50 50 50 50 20 45 45 20 40 20 40 M1 245 245 245 245 245 245 245 245 245 245 245 Connecting 280 40 M 258 258 258 300 300 300 300 300 300 300 300 12 x ø13 R4500 14 x ø13 R5100 Terminal plate thickness for R2500 ... R5100: top and bottom terminal plates = 10 mm 9 R contactor US catalog | 1SXU106047C0201 99 IORR..MT and IORR..CC types R63 … R500 Main dimensions mm Q F R CH = Frame CH CH S W D M CA12 K I1 I CA15 H N ø E A B 22 22 22 B O C F V Z Terminal plate details Lower terminal plate 9 100 Upper terminal plate 1SXU10607C0201 | R contactor US catalog P Y IORR..MT and IORR..CC types R63 … R500 Contactor Number Fixing types holes Fixing Dimensions dimension F of poles R63 R125 R200 R400 R500 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 Fixing - 2 x ø7 2 2 2 2 205 245 285 x ø7 205 285 345 x ø9 245 345 385 x ø13 345 445 540 x ø13 345 445 540 Dimensions - A 45 45 45 57 57 57 69 69 69 79 79 79 79 79 79 B 50 50 61 61 68 68 80 80 80 80 C 93 93 93 93 93 93 116 116 116 160 160 160 160 160 160 Clearing distances - D 148 148 148 153 153 153 190 190 190 260 260 260 260 260 260 E 36 36 36 40 40 40 40 40 40 100 100 100 100 100 100 H 63 63 63 76 76 76 93 93 93 118 118 118 118 118 118 I 114 114 114 138 138 138 140 140 140 230 230 230 230 230 230 I1 101 101 101 130 130 130 123 123 123 195 195 195 195 195 195 K M6 x 20 M6 x 20 M6 x 20 M8 x 20 M8 x 20 M8 x 20 M10 x 25 M10 x 25 M10 x 25 ø13 ø13 ø13 ø13 ø13 ø13 ℓ 16 16 16 20 20 20 25 25 25 30 30 30 30 30 30 M 164 164 164 188 188 188 190 190 190 253 253 253 253 253 253 N 83 83 83 96 96 96 116 116 116 150 150 150 150 150 150 O 12.5 12.5 12.5 12.5 12.5 12.5 9 9 9 15 15 15 15 15 15 P 10.5 10.5 10.5 10.5 10.5 10.5 10 10 10 14 14 14 14 14 14 Q 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 R 23 23 23 23 23 23 20 20 20 20 20 20 20 20 20 S 15 15 15 15 15 15 25 25 25 20 20 20 20 20 20 V 8 8 8 10 10 10 13 13 13 20 20 20 20 20 20 W 16 16 16 20 20 20 20 20 20 46 46 46 46 46 46 Y 178 178 178 183 183 183 220 220 220 290 290 290 290 290 290 Z 8 8 8 10 10 10 12 12 12 20 20 20 20 20 20 Connecting 9 R contactor US catalog | 1SXU106047C0201 101 IORR..MT and IORR..CC types R800 … R2100 Main dimensions mm 50 F 60 D D2 I1 200 200 I M 180 CA15 H CA15 N ø A B D3 B 40 F Y 50 Terminal plate details 48 11.5 25 60 11.5 17.5 25 100 80 17.5 20 40 25 20 2 x ø13 R800 4 x ø11 2 x ø13 R1400 Terminal plate thickness: top terminal plates = 10 mm, bottom terminal plates = 12 mm 102 25 4 x ø11 2 x ø13 R1000 30 25 12.5 25 12.5 25 12.5 9 50 15 11.5 15 25 30 48 11.5 1SXU10607C0201 | R contactor US catalog R1700 R2100 IORR..MT and IORR..CC types R800 … R2100 Contactor types Number Fixing of poles holes R800 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 R1000 R1400 R1700 R2100 Fixing - 4 x ø13 4 x ø13 4 x ø13 4 x ø13 4 x ø13 Dimensions - Fixing Dimensions dimension F A B 245 60 345 60 90 385 60 70 285 60 345 60 90 445 60 80 285 80 385 80 110 540 85 120 300 85 445 85 140 540 85 120 300 85 445 85 140 540 85 120 Clearing distances - D 325 325 325 325 325 325 325 325 325 325 325 325 325 325 325 D2 76 76 76 76 76 76 76 76 76 89 89 89 89 89 89 D3 77 77 77 77 77 77 77 77 77 77 77 77 77 77 77 H 70 70 70 70 70 70 70 70 70 84 84 84 84 84 84 I 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 I1 175 175 175 175 175 175 175 175 175 189 189 189 189 189 189 M 195 195 195 195 195 195 258 258 258 288 288 288 288 288 288 N 90 90 90 90 90 90 100 100 100 125 125 125 125 125 125 Y 375 375 375 375 375 375 425 425 425 450 450 450 450 450 450 Connecting 9 R contactor US catalog | 1SXU106047C0201 103 IORR..MT and IORR..CC types R2500 … R5100 Main dimensions mm 50 F 60 D D2 I1 200 200 I M 180 CA15 H CA15 N ø A B D3 B 40 F Y 50 Fig 1 = right electro-magnet (see table in the following page) 50 F 60 200 M 9 180 CA15 CA15 N ø A B 40 A1 F Fig 2 = central electro-magnet (see table in the following page) 220 180 30 150 30 30 40 35 30 30 50 50 50 35 20 30 40 30 45 45 15 20 30 40 R2500 R3200 Terminal plate thickness for R2500 ... R5100: top and bottom terminal plates = 10 mm 104 8 x ø13 8 x ø13 8 x ø9 1SXU10607C0201 | R contactor US catalog R3800 IORR..MT and IORR..CC types R2500 … R5100 Contactor types Number Fixing of poles holes R2500 1 2 3 1 2 3 1 2 1 2 1 R3200 R3800 R4500 R5100 Fixing - 4 x ø13 4 x ø13 4 x ø13 4 x ø13 4 x ø13 Fixing Dimensions dimension F A A1 385 130 635 135 950 135 135 445 150 760 135 135 950 135 135 445 160 760 145 145 540 185 950 185 180 540 210 - B 220 - Clearing distances - Connecting Dimensions - D 325 325 325 325 325 325 325 325 325 325 325 D2 85 85 85 99 99 99 99 99 99 99 99 D3 87 87 87 87 87 87 87 87 87 87 87 H 135 135 135 174 174 174 174 174 174 174 174 I 108 108 108 108 108 108 108 108 108 108 108 I1 238 238 238 279 279 279 279 279 279 279 279 280 40 40 N 152 152 152 215 215 215 215 215 215 215 215 Y 425 425 425 450 450 450 450 450 450 450 465 Fig 1 1 2 1 2 2 1 2 1 2 1 340 40 40 40 20 50 50 50 50 50 50 20 45 45 20 40 20 40 M 258 258 258 300 300 300 300 300 300 300 300 12 x ø13 R4500 14 x ø13 R5100 Terminal plate thickness for R2500 ... R5100: top and bottom terminal plates = 10 mm 9 R contactor US catalog | 1SXU106047C0201 105 IORR..AME and LORR..AME types R800 … R2100 Main dimensions mm IORR D 50 F 60 LORR D1 D2 200 200 I I1 210 180 LORR M1 IORR M CA15 CA15 N A B H 100 ø B 40 F 50 D3 IORR Y LORR Y1 Terminal plate details 48 11.5 11.5 25 60 11.5 17.5 25 100 80 17.5 40 25 20 2 x ø13 R800 4 x ø11 2 x ø13 R1400 Terminal plate thickness: top terminal plates = 10 mm, bottom terminal plates = 12 mm 106 50 25 4 x ø11 2 x ø13 R1000 30 25 12.5 25 12.5 12.5 25 15 9 20 15 25 30 48 11.5 1SXU10607C0201 | R contactor US catalog R1700 R2100 IORR..AME and LORR..AME types R800 … R2100 Contactor types Number Fixing of poles holes R800 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 R1000 R1400 R1700 R2100 Fixing - 4 x ø13 4 x ø13 4 x ø13 4 x ø13 4 x ø13 Dimensions - Fixing Dimensions dimension F A B 345 60 445 60 90 540 60 70 345 60 445 60 90 540 60 70 385 80 540 80 110 635 85 120 385 85 540 85 140 635 85 120 385 85 540 85 140 635 85 120 Clearing distances - D 325 325 325 325 325 325 325 325 325 325 325 325 325 325 325 D1 260 260 260 260 260 260 260 260 260 260 260 260 260 260 260 D2 75 75 75 75 75 75 76 76 76 75 75 75 75 75 75 D3 77 77 77 77 77 77 77 77 77 77 77 77 77 77 77 H 70 70 70 70 70 70 70 70 70 84 84 84 84 84 84 I 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 I1 98 98 98 98 98 98 98 98 98 112 112 112 112 112 112 M 245 245 245 245 245 245 258 258 258 288 288 288 288 288 288 M1 245 245 245 245 245 245 245 245 245 245 245 245 245 245 245 N 90 90 90 90 90 90 100 100 100 125 125 125 125 125 125 Y 345 345 345 345 345 345 400 400 400 425 425 425 425 425 425 Y1 280 280 280 280 280 280 280 280 280 280 280 280 280 280 280 Connecting 9 R contactor US catalog | 1SXU106047C0201 107 IORR..AME and LORR..AME types R2500 … R5100 Main dimensions mm IORR D 50 F 60 LORR D1 D2 I I1 210 180 LORR M1 IORR M CA15 200 200 LORR types poles are not equiped with arc chutes CA15 N B H 100 ø A B 40 F 50 D3 IORR Y LORR Y1 Fig 1 = right electro-magnet (see table in the following page) 50 F 60 200 M 9 180 CA15 CA15 N ø A B 40 A1 F Fig 2 = central electro-magnet (see table in the following page) 220 180 30 150 30 30 40 35 30 30 50 50 50 35 20 30 40 30 45 45 15 20 30 40 R2500 R3200 Terminal plate thickness for R2500 ... R5100: top and bottom terminal plates = 10 mm 108 8 x ø13 8 x ø13 8 x ø9 1SXU10607C0201 | R contactor US catalog R3800 IORR..AME and LORR..AME types R2500 … R5100 Contactor types Number Fixing of poles holes R2500 1 2 3 1 2 3 1 2 1 2 1 R3200 R3800 R4500 R5100 Fixing - 4 x ø13 4 x ø13 4 x ø13 4 x ø13 4 x ø13 Fixing Dimensions dimensions F A A1 540 130 685 135 1050 135 135 540 150 885 135 135 1050 135 135 540 160 885 145 145 635 185 1050 185 180 635 210 - Dimensions - Clearing distances - B 220 - D 325 325 325 325 325 325 325 325 325 325 325 D1 260 260 260 260 260 260 260 260 260 260 260 D2 85 85 85 99 99 99 99 99 99 99 99 D3 87 87 87 87 87 87 87 87 87 87 87 H 135 135 135 174 174 174 174 174 174 174 174 I 108 108 108 108 108 108 108 108 108 108 108 I1 161 161 161 202 202 202 202 202 202 202 202 40 N 152 152 152 215 215 215 215 215 215 215 215 Y 425 425 425 450 450 450 450 450 450 450 465 Y1 280 280 280 280 280 280 280 280 280 280 280 Fig 1 1 2 1 2 2 1 2 1 2 1 340 40 40 40 20 50 50 50 50 50 50 20 45 45 20 40 20 40 M1 245 245 245 245 245 245 245 245 245 245 245 Connecting 280 40 M 258 258 258 300 300 300 300 300 300 300 300 12 x ø13 R4500 14 x ø13 R5100 Terminal plate thickness for R2500 ... R5100: top and bottom terminal plates = 10 mm 9 R contactor US catalog | 1SXU106047C0201 109 IORR..MT-AMA … IOR..MT-AMA and IORR..CC-AMA … IOR..CC-AMA types R63 … R200 Main dimensions mm Q F R CH = Frame CH CH S W D M CA12 K I1 I CA15 H N ø E A B B O 22 22 F C P V Z Terminal plate details 9 Lower terminal plate 110 Upper terminal plate 1SXU10607C0201 | R contactor US catalog Y IORR..MT-AMA … IOR..MT-AMA and IORR..CC-AMA … IOR..CC-AMA types R63 … R200 Contactor Number Fixing types of poles holes R63 R125 R200 1 2 3 1 2 3 1 2 3 Fixing - 2 x ø7 2 x ø7 2 x ø9 Fixing Dimensions dimension F A B 245 45 285 45 50 345 45 50 285 57 345 57 61 385 57 61 345 69 445 69 68 540 69 68 Dimensions - C 93 93 93 93 93 93 116 116 116 Clearing distances - D 148 148 148 153 153 153 190 190 190 E 36 36 36 40 40 40 40 40 40 H 63 63 63 76 76 76 93 93 93 I 114 114 114 138 138 138 140 140 140 I1 101 101 101 130 130 130 123 123 123 K M6 x 20 M6 x 20 M6 x 20 M8 x 20 M8 x 20 M8 x 20 M10 x 25 M10 x 25 M10 x 25 ℓ 16 16 16 20 20 20 25 25 25 M 164 164 164 188 188 188 190 190 190 N 83 83 83 96 96 96 116 116 116 O 12.5 12.5 12.5 12.5 12.5 12.5 9 9 9 P 10.5 10.5 10.5 10.5 10.5 10.5 10 10 10 Q 53 53 53 53 53 53 53 53 53 R 23 23 23 23 23 23 20 20 20 S 15 15 15 15 15 15 25 25 25 V 8 8 8 10 10 10 13 13 13 W 16 16 16 20 20 20 20 20 20 Y 178 178 178 183 183 183 220 220 220 Z 8 8 8 10 10 10 12 12 12 Connecting 9 R contactor US catalog | 1SXU106047C0201 111 IORR..MT-AME and IORR..CC-AME types R400 … R500 Main dimensions mm Q F R CH CH W D M K I1 CA 15 I 300 S N H ø B 22 22 B O F C P V Z Terminal plate details Lower terminal plate 9 112 Upper terminal plate 1SXU10607C0201 | R contactor US catalog R0021D E A Y IORR..MT-AME and IORR..CC-AME types R400 … R500 Contactor Number Fixing types of poles holes R400 R500 1 2 3 1 2 3 Fixing - Fixing Dimensions dimension F A B C 2 x ø13 445 79 160 540 79 80 160 635 79 80 160 2 x ø13 445 79 160 540 79 80 160 635 79 80 160 Dimensions - Clearing distances - D 260 260 260 260 260 260 E 100 100 100 100 100 100 H 118 118 118 118 118 118 I 230 230 230 230 230 230 I1 195 195 195 195 195 195 K ø13 ø13 ø13 ø13 ø13 ø13 ℓ 30 30 30 30 30 30 M 313 313 313 313 313 313 N 150 150 150 150 150 150 O 15 15 15 15 15 15 P 14 14 14 14 14 14 Q 53 53 53 53 53 53 R 20 20 20 20 20 20 S 20 20 20 20 20 20 V 20 20 20 20 20 20 W 46 46 46 46 46 46 Y 335 335 335 335 335 335 Z 20 20 20 20 20 20 Connecting 9 R contactor US catalog | 1SXU106047C0201 113 IORR..MT-AME and IORR..CC-AME types R800 … R2100 Main dimensions mm D 50 F 60 D2 210 200 200 I I1 M 180 CA15 N ø A B H 100 CA15 B D3 40 F 50 Y Terminal plate details 48 11.5 11.5 25 60 11.5 17.5 25 100 80 17.5 40 25 20 2 x ø13 R800 4 x ø11 2 x ø13 R1400 Terminal plate thickness: top terminal plates = 10 mm, bottom terminal plates = 12 mm 114 50 25 4 x ø11 2 x ø13 R1000 30 25 12.5 25 12.5 12.5 25 15 9 20 15 25 30 48 11.5 1SXU10607C0201 | R contactor US catalog R1700 R2100 IORR..MT-AME and IORR..CC-AME types R800 … R2100 Contactor types Number Fixing of poles holes R800 1 2 3 1 2 3 1 2 3 1 2 3 1 2 3 R1000 R1400 R1700 R2100 Fixing - 4 x ø13 4 x ø13 4 x ø13 4 x ø13 4 x ø13 Dimensions - Fixing Dimensions dimension F A B 345 60 445 60 90 540 60 70 345 60 445 60 90 540 60 80 385 80 540 80 100 635 85 120 385 85 540 85 140 635 85 120 385 85 540 85 140 635 85 120 Clearing distances - D 325 325 325 325 325 325 325 325 325 325 325 325 325 325 325 D2 76 76 76 76 76 76 76 76 76 89 89 89 89 89 89 D3 77 77 77 77 77 77 77 77 77 77 77 77 77 77 77 H 70 70 70 70 70 70 70 70 70 84 84 84 84 84 84 I 108 108 108 108 108 108 108 108 108 108 108 108 108 108 108 I1 175 175 175 175 175 175 175 175 175 189 189 189 189 189 189 M 245 245 245 245 245 245 258 258 258 288 288 288 288 288 288 N 90 90 90 90 90 90 100 100 100 125 125 125 125 125 125 Y 375 375 375 375 375 375 425 425 425 450 450 450 450 450 450 Connecting 9 R contactor US catalog | 1SXU106047C0201 115 IORR..MT-AME and IORR..CC-AME types R2500 … R5100 Main dimensions mm D 50 F 60 D2 210 200 200 I I1 M 180 CA15 N ø A B H 100 CA15 B D3 40 F 50 Y Fig 1 = right electro-magnet (see table in the following page) 50 F 60 CA15 200 M 180 9 CA15 N ø A B 40 A1 F Fig 2 = central electro-magnet (see table in the following page) 220 180 30 150 30 30 40 35 30 30 50 50 50 35 20 30 40 30 45 45 15 20 30 40 R2500 R3200 Terminal plate thickness for R2500 ... R5100: top and bottom terminal plates = 10 mm 116 8 x ø13 8 x ø13 8 x ø9 1SXU10607C0201 | R contactor US catalog R3800 IORR..MT-AME and IORR..CC-AME types R2500 … R5100 Contactor types Number Fixing of poles holes R2500 1 2 3 1 2 3 1 2 1 2 1 R3200 R3800 R4500 R5100 Fixing - 4 x ø13 4 x ø13 4 x ø13 4 x ø13 4 x ø13 Fixing Dimensions dimension F A A1 540 130 685 135 1050 135 135 540 150 885 135 135 1050 135 540 160 885 145 145 635 185 1050 185 180 635 210 - Dimensions - Clearing distances - B 220 220 - D 325 325 325 325 325 325 325 325 325 325 325 B1 - D2 85 85 85 99 99 99 99 99 99 99 99 D3 87 87 87 87 87 87 87 87 87 87 87 H 135 135 135 174 174 174 174 174 174 174 174 I 108 108 108 108 108 108 108 108 108 108 108 I1 238 238 238 279 279 279 279 279 279 279 279 M 258 258 258 300 300 300 300 300 300 300 300 N 152 152 152 215 215 215 215 215 215 215 215 Y 425 425 425 450 450 450 450 450 450 450 465 Fig 1 1 2 1 2 2 1 2 1 2 1 Connecting 9 280 40 40 340 40 40 40 20 50 50 50 50 50 50 20 45 45 20 40 20 40 12 x ø13 R4500 14 x ø13 R5100 Terminal plate thickness for R2500 ... R5100: top and bottom terminal plates = 10 mm R contactor US catalog | 1SXU106047C0201 117 NORR..MT and NORR..CC types R63 … R200 Main dimensions mm Q F R CH = Frame CH CH S W D M CA12 K I1 I CA15 N.C. pole T N.O. pole H N ø E A B 22 22 22 B O C F V Z Terminal plate details Lower terminal plate 9 118 Upper terminal plate 1SXU10607C0201 | R contactor US catalog P Y NORR..MT and NORR..CC types R63 … R200 Contactor Number fixing types of poles holes Fixing Dimensions dimension F R63 205 245 285 345 205 285 345 385 245 345 385 445 R125 R200 1 2 3 4 1 2 3 4 1 2 3 4 Fixing - 2 x ø7 2 x ø7 2 x ø9 Dimensions - A 45 45 45 45 57 57 57 57 69 69 69 69 B 50 50 50 61 61 61 68 68 68 C 93 93 93 93 93 93 93 93 116 116 116 116 Clearing distances - D 148 148 148 148 153 153 153 153 190 190 190 190 E 36 36 36 36 40 40 40 40 40 40 40 40 H 63 63 63 63 76 76 76 76 93 93 93 93 I 114 114 114 114 138 138 138 138 140 140 140 140 I1 101 101 101 101 130 130 130 130 123 123 123 123 K M6 x 20 M6 x 20 M6 x 20 M6 x 20 M8 x 20 M8 x 20 M8 x 20 M8 x 20 M10 x 25 M10 x 25 M10 x 25 M10 x 25 ℓ 16 16 16 16 20 20 20 20 25 25 25 25 M 164 164 164 164 188 188 188 188 190 190 190 190 N 111 111 111 111 126 126 126 126 143 143 143 143 O 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 9 9 9 9 P 10.5 10.5 10.5 10.5 10.5 10.5 10.5 10.5 10 10 10 10 Q 53 53 53 53 53 53 53 53 53 53 53 53 R 23 23 23 23 23 23 23 23 20 20 20 20 S 15 15 15 15 15 15 15 15 25 25 25 25 T 96 96 96 96 111 111 111 111 125 125 125 125 V 8 8 8 8 10 10 10 10 13 13 13 13 W 16 16 16 16 20 20 20 20 20 20 20 20 Y 178 178 178 178 183 183 183 183 220 220 220 220 Z 8 8 8 8 10 10 10 10 12 12 12 12 Connecting 9 R contactor US catalog | 1SXU106047C0201 119 LORR type R85 … R550 Main dimensions mm Q F R CH = Frame CH CH D I1 M S A B O B K C F V Z Terminal plate details 9 Lower terminal plate 120 Upper terminal plate 1SXU10607C0201 | R contactor US catalog H N ø E P Y LORR type R85 … R550 Contactor Number Fixing types of poles holes R85 R170 R260 R400 R550 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 1 2 3 4 Fixing - 2 2 2 2 2 Fixing Dimensions dimension F A B x ø7 175 35 205 35 37 245 35 37 345 35 37 x ø7 175 41 245 41 46 285 41 46 345 41 46 x ø9 205 48 285 45 54.5 345 48 54.5 385 48 54.5 x ø13 345 62 385 62 68 445 62 68 540 62 68 x ø13 345 62 385 62 68 445 62 68 540 62 68 Dimensions - C 93 93 93 93 93 93 93 93 116 116 116 116 160 160 160 160 160 160 160 160 Clearing distances - D 110 110 110 110 110 110 110 110 130 130 130 130 178 178 178 178 178 178 178 178 E 36 36 36 36 40 40 40 40 40 40 40 40 100 100 100 100 100 100 100 100 H 63 63 63 63 76 76 76 76 93 93 93 93 118 118 118 118 118 118 118 118 I1 101 101 101 101 130 130 130 130 123 123 123 123 195 195 195 195 195 195 195 195 K M6 x 20 M6 x 20 M6 x 20 M6 x 20 M8 x 20 M8 x 20 M8 x 20 M8 x 20 M10 x 25 M10 x 25 M10 x 25 M10 x 25 ø13 ø13 ø13 ø13 ø13 ø13 ø13 ø13 ℓ 16 16 16 16 20 20 20 20 25 25 25 25 30 30 30 30 30 30 30 30 M 150 150 150 150 150 150 150 150 167 167 167 167 142 142 142 142 142 142 142 142 N 83 83 83 83 96 96 96 96 116 116 116 116 150 150 150 150 150 150 150 150 O 12.5 12.5 12.5 12.5 12.5 12.5 12.5 12.5 9 9 9 9 15 15 15 15 15 15 15 15 P 10.5 10.5 10.5 10.5 10.5 10.5 10.5 10.5 10 10 10 10 14 14 14 14 14 14 14 14 Q 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 53 R 23 23 23 23 23 23 23 23 20 20 20 20 20 20 20 20 20 20 20 20 S 15 15 15 15 15 15 15 15 25 25 25 25 20 20 20 20 20 20 20 20 V 8 8 8 8 10 10 10 10 13 13 13 13 20 20 20 20 20 20 20 20 Y 125 125 125 125 125 125 125 125 145 145 145 145 193 193 193 193 193 193 193 193 Z 8 8 8 8 10 10 10 10 12 12 12 12 20 20 20 20 20 20 20 20 Connecting 9 R contactor US catalog | 1SXU106047C0201 121 10 122 1SXU10607C0201 | R contactor US catalog Terms and definition Specifications, standards and certifying 124 Terms and technical definitions 125 Utilization categories 126 Climatic withstand of devices 128 10 R contactor US catalog | 1SXU106047C0201 123 Specifications, standards and certifying Definitions ABB low voltage devices are developed and manufactured according to the rules set out in IEC international publications and in EN European specifications. In most countries, low voltage apparatus is built according to such rules with checking being the responsibility of the manufacturer. The devices are therefore not subject to any further obligation for approval. A test report from our laboratories can be remitted to our customers, on request, for presentation to different qualified local organizations. Prescriptions and standards International specifications The International Electrotechnical Commission, IEC, which is part of the International Standards Organization, ISO, publishes IEC publications which act as a basis for the world market. European specifications and national specifications The European Committee for Electrotechnical Standardization (CENELEC), which groups together 18 European countries, publishes EN standards. These European standards differ very little from IEC international standards and have similar numbering. The same applies for national standards which use, without exception, the same numbering and reproduce the texts of these unified standards in their entirety. Contradicting national standards are withdrawn. European directives The guarantee of the free movement of goods within the European Community means that any regulatory differences between member states have been eliminated. The European directives set up common rules that are included in the legislation of each state while contradictory regulations are canceled. Three directives are essential: – Low voltage directive 2006/95/EC concerns electrical equipment from 0 to 1000 V AC and from 75 to 1500 V DC – This specifies that compliance with the requirements that it sets out is acquired if the equipment conforms to the standards harmonized on a European level: EN 60947-1 and EN 60947-4-1 for contactors – Machines directive 2006/42/EC for safety specifications of machines and equipment on complete machines. Machines bearing the ce mark comply with these specifications – Electromagnetic compatibility directive 2004/108/EC which concerns all devices able to create electromagnetic disturbance – Standard EN 60947-4-1 does not set out any requirement concerning the level of emission or immunity of contactors which do not have any active electronic components. Owing to this fact, compliance with standard EN 60947-4-1 meets the requirements for ce marking, with respect to this directive. 10 CE Marking : – must not be confused with a quality label – is proof of conformity with the European Directives concerning the product – is part of an administrative procedure and guarantees free movement of the product within the European Community. International standards IEC 60947-1 Low-voltage switchgear and controlgear – Part 1: General rules. IEC 60947-4-1 Low-voltage switchgear and controlgear – Part 4: Contactors and motor starters. Section 1: Electromechanical contactors and motor starters. IEC 60947-5-1 Low-voltage switchgear and controlgear – Part 5: Control circuit devices and switching elements. Section 1: Electromechanical control circuit devices. European standards EN 60947-1 EN 60947-4-1 Low-voltage switchgear and controlgear – Part 1: General rules. Low-voltage switchgear and controlgear – Part 4: Contactors and motor starters. Section 1: Electromechanical contactors and motor starters. EN 60947-5-1 Low-voltage switchgear and controlgear – Part 5: Control circuit devices and switching elements. Section 1: Electromechanical control circuit devices. 124 1SXU10607C0201 | R contactor US catalog Terms and technical definitions Terminology Rated breaking or making capacity Altitude Root mean square value (R.M.S.) Of the current that the contactor is able to break or make at a given voltage according to the conditions specified by standards and for a given utilization category. Characterizes the place of use. It is expressed in meters above sea level. Circuits – Auxiliary circuit: All the conductive parts of a contactor designed to be inserted in a different circuit from the main circuit and the contactor control circuits. – Control circuit: All the conductive parts of a contactor (other than the main circuit and the auxiliary circuit) used to control the contactor's closing operation or opening operation or both. – Main circuit: All the conductive parts of a contactor designed to be inserted in the circuit that it controls. Rated operational current Ie Current rated by the manufacturer. It is mainly based on the rated operational voltage Ue, the rated frequency, the utilization category, the rated duty and the type of protective enclosure, if necessary. Conventional free air thermal current Ith Ambient temperature Air temperature close to the contactor. Time – Time constant : Ratio of the inductance to the resistance (L/R = mh/Ω = ms). – Short-time withstand current Icw: Current that the contactor is able to withstand in closed position for a short time interval and in specified conditions. – Minimum switching time: This is the minimum closing or opening order time necessary for the contactor to reach complete closing or opening. – Closing time: Time interval between the beginning of the closing operation and the instant the contacts touch on all the poles. – Opening time: Time interval between the specified starting instant of the opening operation and the instant the arcing contacts separate on all the poles. Current that the contactor can withstand in free air for a duty time of 8 hours without the temperature rise of its various parts exceeding the maximum values given by the standard. Rated control voltage Uc Electrical durability Rated operational voltage Ue Number of on-load operating cycles that the contactor is able to carry out. It depends on the utilization category. Voltage to which the contactor's utilization characteristics refer. In three-phase it is the phase-to-phase voltage. Mechanical durability Rated insulation voltage Ui Number of no-current operating cycles that a contactor is able to carry out. Reference voltage for dielectric tests and creepage distances. Control voltage value for which the control circuit is sized. 10 Rated impulse withstand voltage Uimp Switching frequency Number of switching cycles per hour. Peak value of an impulse voltage, having a specified form and polarity, which does not cause breakdown in specific test conditions. Coil operating limits Shock withstand Expressed in multiples of the nominal control circuit voltage Uc for the upper and lower limits. Requirement for vehicles, crane drives, installations on board ships and plug-in equipment. The contactors must not change position and the overload relays must not trip. Mounting position Comply with the manufacturer's instructions. Resistance to vibrations Requirements for vehicles, boats and other means of transport. For the specified vibration amplitude and frequency values the device must remain able to operate. R contactor US catalog | 1SXU106047C0201 125 Utilization categories Standards IEC publications 60941-1, 60947-4-1 and 60947-5-1 should be referred to on an international level with respect to contactors. A contactor's duty is characterised by the utilization category together with the rated operational voltage and current indicated. Utilization categories for contactors according to IEC 60947-4-1 Alternating current: – AC-1 Non-inductive or slightly inductive loads, resistance furnaces – AC-2 Slip-ring motors: starting, switching off – AC-3 Cage motors: starting, switching off running motors – AC-4 Cage motors: starting, plugging, inching – AC-5a Discharge lamp switching – AC-5b Incandescent lamp switching – AC-6a Transformer switching – AC-6b Capacitor bank switching – AC-7a Slightly inductive loads for domestic devices and similar applications – AC-7b Motors for domestic applications – AC-8a Hermetic refrigeration compressor motor control with manual resetting of overload releases – AC-8b Hermetic refrigeration compressor motor control with automatic resetting of overload releases. Direct current: – DC-1 Non inductive or slightly inductive loads, resistance furnaces – DC-3 Shunt motors: starting, plugging, inching, dynamic breaking of DC motors – DC-5 Series motors: starting, plugging, inching, dynamic breaking of DC motors – DC-6 Incandescent lamp switching. 10 126 1SXU10607C0201 | R contactor US catalog Utilization categories for the auxiliary contacts according to IEC 60947-5-1 Alternating current: – AC-12 Control of isolation – AC-13 Control of – AC-14 Control of – AC-15 Control of resistive loads and static loads with opto-coupler static loads with transformer isolation weak electromagnetic loads (≤ 72 VA) electromagnetic loads (> 72 VA). Direct current: – DC-12 Control of resistive loads and static loads with opto-coupler isolation – DC-13 Control of DC electromagnets – DC-14 Control of DC electromagnets having economy resistors. In fact some applications, and the specific criteria characterizing the various loads controlled by contactors, may modify the utilization characteristics of the contactors. DC power circuit switching Arc suppression is more difficult in direct current than in alternating current and this is all the more true the higher the circuit time constant which is why it is necessary to connect several poles in series in order to improve breaking conditions. AC high current circuit switching Possibility of increasing performances by connecting poles in parallel (please consult us). Influence of the length of the conductors used in the contactor control circuit According to the operational voltages and the coil consumption, take line resistances and capacitances into consideration, for the length and the cross-sectional of the conductors. Utilization categories Making and breaking conditions for utilization categories Utilization category Durability test conditions Occasional operation Making conditions I/Ie U/Ue Breaking conditions Making conditions Breaking conditions Cos. φ or L/R (ms) I/Ie U/Ue Cos. φ or L/R (ms) Ic/Ie Ur/Ue Cos. φ or L/R (ms) Ic/Ie Ur/Ue Cos. φ or L/R (ms) Contactors for AC circuit switching AC-1 1 1 AC-2 2.5 1 AC-3 Ie ≤ 100 A 6 1 Ie > 100 A 6 1 AC-4 Ie ≤ 100 A 6 1 Ie > 100 A 6 1 0.95 0.65 0.35 0.35 0.35 0.35 1 2.5 1 1 6 6 1 1 0.17 0.17 1 1 0.95 0.65 0.35 0.35 0.35 0.35 1.5 4 10 10 12 12 1.05 1.05 1.05 1.05 1.05 1.05 0.8 0.65 0.45 0.35 0.45 0.35 1.5 4 8 8 10 10 1.05 1.05 1.05 1.05 1.05 1.05 0.8 0.65 0.45 0.35 0.45 0.35 Contactors for DC circuit switching DC-1 1 1 DC-3 2.5 1 DC-5 2.5 1 1 2 7.5 1 2.5 2.5 1 1 1 1 2 7.5 1.5 4 4 1.05 1.05 1.05 1 2.5 15 1.5 4 4 1.05 1.05 1.05 1 2.5 15 1 1 0.4 6 10 1.1 1.1 0.7 0.3 6 10 1.1 1.1 0.7 0.3 Auxiliary contacts for AC circuit switching AC-14 (≤ 72 VA) AC-15 (> 72 VA) 10 1 0.7 Auxiliary contacts for DC circuit switching Utilization category Standard operation Making conditions DC-13 DC-14 I/Ie 1 - U/Ue 1 - Occasional operation Breaking conditions T0.95 6 P (1) - I/Ie 1 - U/Ue 1 - Making conditions T0.95 6 P (1) - I/Ie 1.1 10 U/Ue 1.1 1.1 Breaking conditions T0.95 6 P (1) 15 ms I/Ie 1.1 10 U/Ue 1.1 1.1 T0.95 6 P (1) 15 ms (1) The value "6 x P" is the result of an empirical relation which is estimated to represent most DC magnetic loads up to the highest limit of P = 50 W (6 x P = 300 ms). It is accepted that loads having drawn energy above 50 W are made up of weaker loads in parallel. As a consequence, the 300 ms value must form the highest limit whatever the value of the power drawn. Key: U (I) Ur L/R Ue (Ie) = applied voltage (current) = recovery voltage = test circuit time constant = rated operational voltage (current) Ic = making and breaking current expressed in DC or in AC like the r.m.s. value of the symmetrical components T0.95 = time required to reach 95 % of the current in steady-state conditions, expressed in milliseconds R contactor US catalog | 1SXU106047C0201 10 127 Climatic withstand of devices General The life time and dependability of devices are mainly influenced by a series of climatic factors which cause their corrosion. In practice, besides climatic conditions, there are other factors which may damage equipment such as fungi, insects (termites), dust, work site dirt and aggressive environment (salty or sulphurous atmosphere, etc.) which can often only be identified at the place of installation. The entrance of dust, insects, dirt, etc. in devices may be prevented if the appropriate degree of protection according to IEC 60529 is chosen. ABB contactors have been used for many years in the most varied countries, with hot and humid climates for example: Brazil, Indonesia, India etc. Experience has shown that ABB devices can be used in most countries throughout the world. The climate of the country in which the device is installed is not the determining choice factor. Account must be taken of: – the immediate environment of the devices (sheltered, ventilated, temperature) – the aggressiveness of the immediate atmosphere at the place of installation – the length and frequency of non operating periods. In the case of frequent condensation (Ie the formation of steam caused by rapid changes in temperature), heating resistors must be installed in cubicles (100 to 250 W per m3 of enclosure). The table below gives the cases where heating is necessary. Environment Operating conditions Climate Internal heating of enclosure no running water, no condensation Continuous or not All climates Without with running water Continuous Frequent or long stops Outside, sheltered no running water, no condensation Continuous or not All climates Temperate Tropical Temperate Without Without With Without Outside or by the seaside with running water Continuous Frequent or long stops Tropical All climates Temperate Tropical With Without Without With Inside premises 10 The standard R series contactors are suitable for industrial environment and tropical atmospheres. 128 1SXU10607C0201 | R contactor US catalog Notes R contactor US catalog | 1SXU106047C0201 129 Questionnaire Specification for R contactors Customer ................................................................................................................. Contact person ...................................................... Date .............................. Tel. .......................................................... e-mail .................................................. ABB ............................................................................................................................. Contact person .................................................................................................... Tel. ............................................................................................................................... Quantity ................... Requested delivery date ..................................... Project / Application ........................................................................................................................................................................................................................................... Power circuit Auxiliary contacts AC switching Application type AC-1 (resistive load) AC-3 (direct starting, switching off running motors) No load breaking Other .............................................................................................. Number of poles: N.O. ..................... N.C. ..................... Rated operational current Ie .................. A Max. making current ............................ A Max. breaking current ......................... A Rated operational voltage Ue ............... V ............... Hz Number of N.O. auxiliary contacts Number of N.C. auxiliary contacts ............ ............. or DC switching Application type DC-1 (resistive load) DC-3 (shunt motors) DC-5 (series motors) No load breaking Other ....................................... L/R .............. ms Number of poles: N.O. ..................... N.C. ..................... Rated operational current Ie .................. A Making current ........................................ A max. .......... A Breaking current min. .......... A Rated operational voltage Ue ............... V DC 11 Operating conditions Switching frequency ............................................. cycles/h Mech. durability required (millions of operating cycles) .............. Remarks .......................................................................................... Accessories Control circuit (coil) AC Voltage ..................... V ............... Hz Voltage ..................... V DC DC Options Magnetic/Mechanical latching option ............................................................................................................................................................................................................................................. Please add any other useful documents for further information e.g. technical specification, drawing, wiring diagram, etc. Brand ................................................................ Type .................................................................. Fixing dimension F = ............... mm Overall dimensions W = ............... mm H = ............... mm D = ............... mm H Replacement of an existing contactor F D W Please photocopy and forward. Questionnaire also available on the ABB Website: www.abb.com/lowvoltage Section: Our offering Select: Control Products > Contactors > Bar mounted contactors 130 1SXU10607C0201 | R contactor US catalog Questionnaire Specification for R contactors Other information / Application type 11 This document is used to define the contactor specification according to the complete information on the application Please photocopy and forward. Questionnaire also available on the ABB Website: www.abb.com/lowvoltage Section: Our offering Select: Control Products > Contactors > Bar mounted contactors R contactor US catalog | 1SXU106047C0201 131 Index Order code classification Order code 12 132 Type Page Order code Type Page Order code Type Page FPL6115215R2113 IORR1400-20 24 FPL6335310R2113 LORR2100-30 55 FPL6816225R2223 IORR4500-20-CC-AME 40 FPL6115225R2223 IORR1400-20-AME 26 FPL6335410R2113 LORR2100-40 55 FPL6825002R2113 IORR4500-30-MT 25 FPL6115315R2113 IORR1400-30 24 FPL6515215R2113 IORR3200-20 24 FPL6825215R2113 IORR4500-20-MT 25 FPL6115325R2223 IORR1400-30-AME 26 FPL6515225R2223 IORR3200-20-AME 26 FPL6825225R2123 IORR4500-20-MT-AME 27 FPL6115415R2113 IORR1400-40 24 FPL6515315R2113 IORR3200-30 24 FPL6835001R2113 LORR4500-30 55 FPL6115425R2223 IORR1400-40-AME 26 FPL6515325R2223 IORR3200-30-AME 26 FPL6835110R2113 LORR4500-10 55 FPL6116125R2223 IORR1400-10-CC-AME 40 FPL6516115R2113 IORR3200-10-CC 38 FPL6835210R2113 LORR4500-20 55 FPL6116195R2113 IORR1400-10-CC-U 39 FPL6516125R2223 IORR3200-10-CC-AME 40 FPL6915001R2113 IORR5100-20 24 FPL6116215R2113 IORR1400-20-CC 38 FPL6516215R2113 IORR3200-20-CC 38 FPL6915002R2113 IORR5100-30 24 FPL6116225R2223 IORR1400-20-CC-AME 40 FPL6516225R2223 IORR3200-20-CC-AME 40 FPL6916001R2113 IORR5100-30-CC 38 FPL6116315R2113 IORR1400-30-CC 38 FPL6516315R2113 IORR3200-30-CC 38 FPL6916002R2113 IORR5100-20-CC 38 FPL6116325R2223 IORR1400-30-CC-AME 40 FPL6516325R2223 IORR3200-30-CC-AME 40 FPL6916115R2113 IORR5100-10-CC 38 FPL6125215R2113 IORR1400-20-MT 25 FPL6525215R2113 IORR3200-20-MT 25 FPL6916125R2223 IORR5100-10-CC-AME 40 FPL6125225R2123 IORR1400-20-MT-AME 27 FPL6525225R2123 IORR3200-20-MT-AME 27 FPL6925001R2113 IORR5100-20-MT 25 FPL6125315R2113 IORR1400-30-MT 25 FPL6525315R2113 IORR3200-30-MT 25 FPL6925002R2113 IORR5100-30-MT 25 FPL6125325R2123 IORR1400-30-MT-AME 27 FPL6525325R2123 IORR3200-30-MT-AME 27 FPL6935001R2113 LORR5100-20 55 FPL6125415R2113 IORR1400-40-MT 25 FPL6535001R2113 LORR3200-40 55 FPL6935110R2113 LORR5100-10 55 FPL6135110R2113 LORR1400-10 55 FPL6535110R2113 LORR3200-10 55 FPL7101403R0001 VM21/24 83 FPL6135210R2113 LORR1400-20 55 FPL6535210R2113 LORR3200-20 55 FPL7108201P0001 4NMW1009 84 FPL6135310R2113 LORR1400-30 55 FPL6535310R2113 LORR3200-30 55 FPL7116116R2113 IORR63-10-CC 38 FPL6135410R2113 LORR1400-40 55 FPL6615001R2113 IORR3800-30 24 FPL7116136R2123 IORR63-10-CC-AMA 40 FPL6215215R2113 IORR1700-20 24 FPL6615215R2113 IORR3800-20 24 FPL7116216R2113 IORR63-20-CC 38 FPL6215225R2223 IORR1700-20-AME 26 FPL6615225R2223 IORR3800-20-AME 26 FPL7116236R2123 IORR63-20-CC-AMA 40 FPL6215315R2113 IORR1700-30 24 FPL6616001R2113 IORR3800-30-CC 38 FPL7125216R2113 IORR63-20-MT 25 FPL6215325R2223 IORR1700-30-AME 26 FPL6616115R2113 IORR3800-10-CC 38 FPL7125236R2123 IORR63-20-MT-AMA 27 FPL6215415R2113 IORR1700-40 24 FPL6616125R2223 IORR3800-10-CC-AME 40 FPL7125336R2123 IORR63-30-MT-AMA 27 FPL6215425R2223 IORR1700-40-AME 26 FPL6616195R2113 IORR1400-10-CC-U 38 FPL7125386R2113 IORR63-30-MT 25 FPL6216125R2223 IORR1700-10-CC-AME 40 FPL6616215R2113 IORR3800-20-CC 38 FPL7125416R2113 IORR63-40-MT 25 FPL6216195R2113 IORR1700-10-CC-U 38 FPL6616225R2223 IORR3800-20-CC-AME 40 FPL7125436R2123 IORR63-40-MT-AMA 27 FPL6216195R2113 IORR1700-10-CC-U 39 FPL6625001R2113 IORR3800-30-MT 25 FPL7146116R2113 NORR63-01-CC 50 FPL6216215R2113 IORR1700-20-CC 38 FPL6625215R2113 IORR3800-20-MT 25 FPL7146216R2113 NORR63-02-CC 50 FPL6216225R2223 IORR1700-20-CC-AME 40 FPL6625225R2123 IORR3800-20-MT-AME 27 FPL7146516R2113 NORR63-21-CC 50 FPL6216315R2113 IORR1700-30-CC 38 FPL6625325R2123 IORR3800-30-MT-AME 27 FPL7146716R2113 NORR63-31-CC 50 FPL6216325R2223 IORR1700-30-CC-AME 40 FPL6635002R2113 LORR3800-30 55 FPL7155216R2113 NORR63-02-MT 49 FPL6225215R2113 IORR1700-20-MT 25 FPL6635003R2113 LORR3800-40 55 FPL7155516R2113 NORR63-21-MT 49 FPL6225225R2123 IORR1700-20-MT-AME 27 FPL6635110R2113 LORR3800-10 55 FPL7155716R2113 NORR63-31-MT 49 FPL6225315R2113 IORR1700-30-MT 25 FPL6635210R2113 LORR3800-20 55 FPL7235110R2113 LORR85-10 55 FPL6225325R2123 IORR1700-30-MT-AME 27 FPL6715215R2113 IORR2500-20 24 FPL7235210R2113 LORR85-20 55 FPL6225415R2113 IORR1700-40-MT 25 FPL6715225R2223 IORR2500-20-AME 26 FPL7235310R2113 LORR85-30 55 FPL6235110R2113 LORR1700-10 55 FPL6715315R2113 IORR2500-30 24 FPL7235410R2113 LORR85-40 55 FPL6235210R2113 LORR1700-20 55 FPL6715325R2223 IORR2500-30-AME 26 FPL7401404R0001 VM25 83 FPL6235310R2113 LORR1700-30 55 FPL6716115R2113 IORR2500-10-CC 38 FPL7416115R2113 IORR125-10-CC 38 FPL6235410R2113 LORR1700-40 55 FPL6716125R2223 IORR2500-10-CC-AME 40 FPL7416135R2123 IORR125-10-CC-AMA 40 FPL6315215R2113 IORR2100-20 24 FPL6716215R2113 IORR2500-20-CC 38 FPL7416215R2113 IORR125-20-CC 38 FPL6315225R2223 IORR2100-20-AME 26 FPL6716225R2223 IORR2500-20-CC-AME 40 FPL7416235R2123 IORR125-20-CC-AMA 40 FPL6315315R2113 IORR2100-30 24 FPL6716315R2113 IORR2500-30-CC 38 FPL7425215R2113 IORR125-20-MT 25 FPL6315325R2223 IORR2100-30-AME 26 FPL6716325R2223 IORR2500-30-CC-AME 40 FPL7425235R2123 IORR125-20-MT-AMA 27 FPL6315415R2113 IORR2100-40 24 FPL6725215R2113 IORR2500-20-MT 25 FPL7425315R2113 IORR125-30-MT 25 FPL6315425R2223 IORR2100-40-AME 26 FPL6725225R2123 IORR2500-20-MT-AME 27 FPL7425335R2123 IORR125-30-MT-AMA 27 FPL6316125R2223 IORR2100-10-CC-AME 40 FPL6725315R2113 IORR2500-30-MT 25 FPL7425415R2113 IORR125-40-MT 25 FPL6316195R2113 IORR2100-10-CC-U 38 FPL6725325R2123 IORR2500-30-MT-AME 27 FPL7425435R2123 IORR125-40-MT-AMA 27 FPL6316195R2113 IORR2100-10-CC-U 39 FPL6725415R2113 IORR2500-40-MT 25 FPL7446115R2113 NORR125-01-CC 50 FPL6316215R2113 IORR2100-20-CC 38 FPL6735110R2113 LORR2500-10 55 FPL7446215R2113 NORR125-02-CC 50 FPL6316225R2223 IORR2100-20-CC-AME 40 FPL6735210R2113 LORR2500-20 55 FPL7446515R2113 NORR125-21-CC 50 FPL6316315R2113 IORR2100-30-CC 38 FPL6735310R2113 LORR2500-30 55 FPL7446715R2113 NORR125-31-CC 50 FPL6316325R2223 IORR2100-30-CC-AME 40 FPL6735410R2113 LORR2500-40 55 FPL7455215R2113 NORR125-02-MT 49 FPL6325215R2113 IORR2100-20-MT 25 FPL6815001R2113 IORR4500-30 24 FPL7455515R2113 NORR125-21-MT 49 FPL6325225R2123 IORR2100-20-MT-AME 27 FPL6815215R2113 IORR4500-20 24 FPL7455715R2113 NORR125-31-MT 49 FPL6325315R2113 IORR2100-30-MT 25 FPL6815225R2223 IORR4500-20-AME 26 FPL7535110R2113 LORR170-10 55 FPL6325325R2123 IORR2100-30-MT-AME 27 FPL6816001R2113 IORR4500-30-CC 38 FPL7535210R2113 LORR170-20 55 FPL6325415R2113 IORR2100-40-MT 25 FPL6816115R2113 IORR4500-10-CC 38 FPL7535310R2113 LORR170-30 55 FPL6335110R2113 LORR2100-10 55 FPL6816125R2223 IORR4500-10-CC-AME 40 FPL7535410R2113 LORR170-40 55 FPL6335210R2113 LORR2100-20 55 FPL6816215R2113 IORR4500-20-CC 38 FPL7608201P0001 4NMW1039 84 1SXU10607C0201 | R contactor US catalog Index Order code classification Order code Type Page Order code Type Page Order code Type Page FPL7616115R2113 IORR200-10-CC 38 FPL8645715R2113 NORR800-31 49 FPTN410067R0002 ARC CHUTE 81 FPL7616135R2123 IORR200-10-CC-AMA 40 FPL8646115R2113 NORR800-01-CC 50 FPTN410111R0001 FPL7616215R2113 IORR200-20-CC 38 FPL8646215R2113 NORR800-02-CC 50 SHAFT EXTENSION R63… R170 84 FPL7616235R2123 IORR200-20-CC-AMA 40 FPL8646515R2113 NORR800-21-CC 50 FPTN410111R0002 FPL7625215R2113 IORR200-20-MT 25 FPL8646715R2113 NORR800-31-CC 50 SHAFT EXTENSION R200… R420 84 FPTN410111R0003 SHAFT EXTENSION R400, 500 550 84 FPTN410176R0006 EQUIPOTENTIAL CONNECTION 81 FPTN410176R0007 EQUIPOTENTIAL CONNECTION 81 FPTN410200R0006 MAGNET SET FOR MAIN COIL 82 MOUNTING KIT 77 FPL7625235R2123 IORR200-20-MT-AMA 27 FPL8655215R2113 NORR800-02-MT 49 FPL7625315R2113 IORR200-30-MT 25 FPL8655515R2113 NORR800-21-MT 49 FPL7625335R2123 IORR200-30-MT-AMA 27 FPL8655715R2113 NORR800-31-MT 49 FPL7625415R2113 IORR200-40-MT 25 FPL8715215R2113 IORR1000-20 24 FPL7625435R2123 IORR200-40-MT-AMA 27 FPL8715225R2223 IORR1000-20-AME 26 FPL7646115R2113 NORR200-01-CC 50 FPL8715315R2113 IORR1000-30 24 FPL7646215R2113 NORR200-02-CC 50 FPL8715325R2223 IORR1000-30-AME 26 FPL7646515R2113 NORR200-21-CC 50 FPL8715415R2113 IORR1000-40 24 FPTN410213R0006 FPL7646715R2113 NORR200-31-CC 50 FPL8715425R2223 IORR1000-40-AME 26 FPTN410389R0001 FPL7655215R2113 NORR200-02-MT 49 FPL8716125R2223 IORR1000-10-CC-AME 40 CONTACT SET WITH ARCING HORN 80 FPTN410389R0002 CONTACT SET WITH ARCING HORN 80 FPTN410389R0003 CONTACT SET WITH ARCING HORN 80 FPTN410389R0004 CONTACT SET WITH ARCING HORN 80 FPTN410389R0005 CONTACT SET WITH ARCING HORN 80 FPTN410390R0001 CONTACT SET WITH ARCING HORN 80 FPTN410390R0002 CONTACT SET WITH ARCING HORN 80 FPTN410390R0003 CONTACT SET WITH ARCING HORN 80 FPTN410390R0004 CONTACT SET WITH ARCING HORN 80 FPTN410390R0005 CONTACT SET WITH ARCING HORN 80 FPTN410391R0001 CONTACT SET WITH ARCING HORN 80 FPTN410437R0001 MAGNET SET FOR MAIN COIL 82 FPTN410438R0001 MAGNET SET FOR MAIN COIL 82 FPTN410439R0001 MAGNET SET FOR MAIN COIL 82 FPTN410441R0001 MAGNET SET FOR MAIN COIL 82 FPTN410446R0001 ARCING HORN 80 FPTN410446R0001 ARCING HORN 80 FPTN410463R6001 RV-R1/60 82 FPTN410463R6002 RV-R1/133 82 FPL7655515R2113 NORR200-21-MT 49 FPL8716195R2113 IORR1000-10-CC-U 38 FPL7655715R2113 NORR200-31-MT 49 FPL8716195R2113 IORR1000-10-CC-U 39 FPL7835110R2113 LORR260-10 55 FPL8716215R2113 IORR1000-20-CC 38 FPL7835210R2113 LORR260-20 55 FPL8716225R2223 IORR1000-20-CC-AME 40 FPL7835310R2113 LORR260-30 55 FPL8716315R2113 IORR1000-30-CC 38 FPL7835410R2113 LORR260-40 55 FPL8716325R2223 IORR1000-30-CC-AME 40 FPL8001401R0001 VM27 83 FPL8801401R0001 VM17/18 83 FPL8301401R0002 VM15-SP 83 FPL9001401R0001 VM19 83 FPL8308201P0001 4NMW1041 84 FPL9416115R2113 IORR400-10-CC 38 FPL8316115R2113 IORR500-10-CC 38 FPL9416125R2223 IORR400-10-CC-AME 40 FPL8316125R2223 IORR500-10-CC-AME 40 FPL9416215R2113 IORR400-20-CC 38 FPL8316215R2113 IORR500-20-CC 38 FPL9416225R2223 IORR400-20-CC-AME 40 FPL8316225R2223 IORR500-20-CC-AME 40 FPL9416325R2223 IORR400-30-CC-AME 40 FPL8316325R2223 IORR500-30-CC-AME 40 FPL9425215R2113 IORR400-20-MT 25 FPL8325215R2113 IORR500-20-MT 25 FPL9425225R2123 IORR400-20-MT-AME 27 FPL8325225R2123 IORR500-20-MT-AME 27 FPL9425315R2113 IORR400-30-MT 25 FPL8325315R2113 IORR500-30-MT 25 FPL9425325R2123 IORR400-30-MT-AME 27 FPL8325325R2123 IORR500-30-MT-AME 27 FPL9425415R2113 IORR400-40-MT 25 FPL8325415R2113 IORR500-40-MT 25 FPL9435110R2113 LORR400-10 55 FPL8435110R2113 LORR550-10 55 FPL9435210R2113 LORR400-20 55 FPL8435210R2113 LORR550-20 55 FPL9435310R2113 LORR400-30 55 FPL8435310R2113 LORR550-30 55 FPL9435410R2113 LORR400-40 55 FPL8435410R2113 LORR550-40 55 FPL9445115R2113 NORR400-01 50 FPL8601401R0001 VM16 83 FPL9445215R2113 NORR400-02 49 FPL8615215R2113 IORR800-20 24 FPL9445215R2113 NORR400-02 50 FPL8615225R2223 IORR800-20-AME 26 FPL9445515R2113 NORR400-21 49 FPL8615315R2113 IORR800-30 24 FPL9445515R2113 NORR400-21 50 FPL8615325R2223 IORR800-30-AME 26 FPL9445715R2113 NORR400-31 49 FPL8615415R2113 IORR800-40 24 FPL9445715R2113 NORR400-31 50 FPL8615425R2223 IORR800-40-AME 26 FPTN210382R0003 CA15-F 77 FPTN410463R6003 RV-R1/250 82 FPL8616125R2223 IORR800-10-CC-AME 40 FPTN210382R0004 CA15-O 77 FPTN410463R6004 RV-R1/440 82 FPL8616195R2113 IORR800-10-CC-U 38 FPTN401936R0002 ARC CHUTE 81 FPTN410463R6005 RV-R1/660 82 FPTN410503R0001 CONTACT SET WITH ARCING HORN 80 FPTN410506R0001 CONTACT SET WITH ARCING HORN 80 FPTN410507R0001 ARC CHUTE 81 FPTN410508R0001 ARCING HORN 80 TRE2614501 RECTIFIER BRIDGE 82 TRE2720806 RECTIFIER BRIDGE 82 On request IORR125-30-CC 38 On request IORR125-30-CC-AMA 40 FPL8616195R2113 IORR800-10-CC-U 39 FPTN401938R0002 ARC CHUTE 81 FPL8616215R2113 IORR800-20-CC 38 FPTN401939R0002 ARC CHUTE 81 FPL8616225R2223 IORR800-20-CC-AME 40 FPTN401940R0002 ARC CHUTE 81 FPL8616315R2113 IORR800-30-CC 38 FPTN401941R0002 ARC CHUTE 81 FPL8616325R2223 IORR800-30-CC-AME 40 FPTN410004R0001 CA12-1 77 FPL8625215R2113 IORR800-20-MT 25 FPTN410005R0001 CA12-2 77 FPL8625225R2123 IORR800-20-MT-AME 27 FPTN410007R0006 CA15-O 77 FPL8625315R2113 IORR800-30-MT 25 FPTN410008R0004 CA15-F 77 FPL8625325R2123 IORR800-30-MT-AME 27 FPTN410012R0001 CA12-22 77 FPL8625415R2113 IORR800-40-MT 25 FPTN410013R0001 CA12-11 77 FPL8635110R2113 LORR800-10 55 FPTN410016R0001 CA12-12 77 On request IORR200-30-CC 38 FPL8635210R2113 LORR800-20 55 FPTN410054R0016 UNIVERSAL MOUNTING KIT 77 On request IORR200-30-CC-AMA 40 FPL8635310R2113 LORR800-30 55 FPTN410054R0017 MOUNTING KIT 77 On request IORR400-30-CC 38 FPL8635410R2113 LORR800-40 55 FPTN410056R0001 CA12-1 SUPPORT BRACKET 77 On request IORR500-30-CC 38 FPL8645215R2113 NORR800-02 49 FPTN410056R0002 CA12 SUPPORT BRACKET 77 On request IORR63-30-CC 38 FPL8645515R2113 NORR800-21 49 FPTN410067R0002 ARC CHUTE 81 On request IORR63-30-CC-AMA 40 R contactor US catalog | 1SXU106047C0201 12 133 Index Type classification Type Order code 4NMW1009 FPL7108201P0001 4NMW1039 FPL7608201P0001 Order code Page Type Order code Page 84 IORR1000-40-AME FPL8715425R2223 26 IORR2100-20 FPL6315215R2113 24 84 IORR125-10-CC FPL7416115R2113 38 IORR2100-20-AME FPL6315225R2223 26 FPL8308201P0001 84 IORR125-10-CC-AMA FPL7416135R2123 40 IORR2100-20-CC FPL6316215R2113 38 ARC CHUTE FPTN401938R0002 81 IORR125-20-CC FPL7416215R2113 38 IORR2100-20-CC-AME FPL6316225R2223 40 ARC CHUTE FPTN401939R0002 81 IORR125-20-CC-AMA FPL7416235R2123 40 IORR2100-20-MT FPL6325215R2113 25 ARC CHUTE FPTN401940R0002 81 IORR125-20-MT FPL7425215R2113 25 IORR2100-20-MT-AME FPL6325225R2123 27 ARC CHUTE FPTN401936R0002 81 IORR125-20-MT-AMA FPL7425235R2123 27 IORR2100-30 FPL6315315R2113 24 ARC CHUTE FPTN401941R0002 81 IORR125-30-CC On request 38 IORR2100-30-AME FPL6315325R2223 26 ARC CHUTE FPTN410067R0002 81 IORR125-30-CC-AMA On request 40 IORR2100-30-CC FPL6316315R2113 38 ARC CHUTE FPTN410067R0002 81 IORR125-30-MT FPL7425315R2113 25 IORR2100-30-CC-AME FPL6316325R2223 40 ARC CHUTE FPTN410507R0001 81 IORR125-30-MT-AMA FPL7425335R2123 27 IORR2100-30-MT FPL6325315R2113 25 ARCING HORN FPTN410446R0001 80 IORR125-40-MT FPL7425415R2113 25 IORR2100-30-MT-AME FPL6325325R2123 27 ARCING HORN FPTN410446R0001 80 IORR125-40-MT-AMA FPL7425435R2123 27 IORR2100-40 FPL6315415R2113 24 ARCING HORN FPTN410508R0001 80 IORR1400-10-CC-AME FPL6116125R2223 40 IORR2100-40-AME FPL6315425R2223 26 CA12 SUPPORT BRACKET IORR1400-10-CC-U FPL6616195R2113 38 IORR2100-40-MT FPL6325415R2113 25 FPTN410056R0002 77 IORR1400-10-CC-U FPL6116195R2113 39 IORR2500-10-CC FPL6716115R2113 38 CA12-1 FPTN410004R0001 77 IORR1400-20 FPL6115215R2113 24 IORR2500-10-CC-AME FPL6716125R2223 40 CA12-1 SUPPORT BRACKET FPTN410056R0001 77 IORR1400-20-AME FPL6115225R2223 26 IORR2500-20 FPL6715215R2113 24 CA12-11 FPTN410013R0001 77 IORR1400-20-CC FPL6116215R2113 38 IORR2500-20-AME FPL6715225R2223 26 CA12-12 FPTN410016R0001 77 IORR1400-20-CC-AME FPL6116225R2223 40 IORR2500-20-CC FPL6716215R2113 38 CA12-2 FPTN410005R0001 77 IORR1400-20-MT FPL6125215R2113 25 IORR2500-20-CC-AME FPL6716225R2223 40 CA12-22 FPTN410012R0001 77 IORR1400-20-MT-AME FPL6125225R2123 27 IORR2500-20-MT FPL6725215R2113 25 CA15-F FPTN410008R0004 77 IORR1400-30 FPL6115315R2113 24 IORR2500-20-MT-AME FPL6725225R2123 27 CA15-F FPTN210382R0003 77 IORR1400-30-AME FPL6115325R2223 26 IORR2500-30 FPL6715315R2113 24 CA15-O FPTN410007R0006 77 IORR1400-30-CC FPL6116315R2113 38 IORR2500-30-AME FPL6715325R2223 26 CA15-O FPTN210382R0004 77 IORR1400-30-CC-AME FPL6116325R2223 40 IORR2500-30-CC FPL6716315R2113 38 CONTACT SET WITH ARCING HORN IORR1400-30-MT FPL6125315R2113 25 IORR2500-30-CC-AME FPL6716325R2223 40 FPTN410389R0001 80 IORR1400-30-MT-AME FPL6125325R2123 27 IORR2500-30-MT FPL6725315R2113 25 IORR1400-40 FPL6115415R2113 24 IORR2500-30-MT-AME FPL6725325R2123 27 IORR1400-40-AME FPL6115425R2223 26 IORR2500-40-MT FPL6725415R2113 25 IORR1400-40-MT FPL6125415R2113 25 IORR3200-10-CC FPL6516115R2113 38 IORR1700-10-CC-AME FPL6216125R2223 40 IORR3200-10-CC-AME FPL6516125R2223 40 IORR1700-10-CC-U FPL6216195R2113 38 IORR3200-20 FPL6515215R2113 24 IORR1700-10-CC-U FPL6216195R2113 39 IORR3200-20-AME FPL6515225R2223 26 FPTN410389R0002 80 CONTACT SET WITH ARCING HORN FPTN410389R0003 80 CONTACT SET WITH ARCING HORN FPTN410389R0004 80 CONTACT SET WITH ARCING HORN CONTACT SET WITH ARCING HORN CONTACT SET WITH ARCING HORN FPTN410389R0005 FPTN410390R0001 FPTN410390R0002 80 80 80 CONTACT SET WITH ARCING HORN FPTN410390R0003 80 CONTACT SET WITH ARCING HORN FPTN410390R0004 80 CONTACT SET WITH ARCING HORN FPTN410390R0005 80 CONTACT SET WITH ARCING HORN FPTN410391R0001 80 CONTACT SET WITH ARCING HORN 134 Type 4NMW1041 CONTACT SET WITH ARCING HORN 12 Page FPTN410503R0001 80 IORR1700-20 FPL6215215R2113 24 IORR3200-20-CC FPL6516215R2113 38 IORR1700-20-AME FPL6215225R2223 26 IORR3200-20-CC-AME FPL6516225R2223 40 IORR1700-20-CC FPL6216215R2113 38 IORR3200-20-MT FPL6525215R2113 25 IORR1700-20-CC-AME FPL6216225R2223 40 IORR3200-20-MT-AME FPL6525225R2123 27 IORR1700-20-MT FPL6225215R2113 25 IORR3200-30 FPL6515315R2113 24 IORR1700-20-MT-AME FPL6225225R2123 27 IORR3200-30-AME FPL6515325R2223 26 IORR1700-30 FPL6215315R2113 24 IORR3200-30-CC FPL6516315R2113 38 IORR1700-30-AME FPL6215325R2223 26 IORR3200-30-CC-AME FPL6516325R2223 40 IORR1700-30-CC FPL6216315R2113 38 IORR3200-30-MT FPL6525315R2113 25 IORR1700-30-CC-AME FPL6216325R2223 40 IORR3200-30-MT-AME FPL6525325R2123 27 IORR1700-30-MT FPL6225315R2113 25 IORR3800-10-CC FPL6616115R2113 38 IORR1700-30-MT-AME FPL6225325R2123 27 IORR3800-10-CC-AME FPL6616125R2223 40 IORR1700-40 FPL6215415R2113 24 IORR3800-20 FPL6615215R2113 24 IORR1700-40-AME FPL6215425R2223 26 IORR3800-20-AME FPL6615225R2223 26 IORR1700-40-MT FPL6225415R2113 25 IORR3800-20-CC FPL6616215R2113 38 IORR200-10-CC FPL7616115R2113 38 IORR3800-20-CC-AME FPL6616225R2223 40 IORR200-10-CC-AMA FPL7616135R2123 40 IORR3800-20-MT FPL6625215R2113 25 IORR200-20-CC FPL7616215R2113 38 IORR3800-20-MT-AME FPL6625225R2123 27 40 IORR200-20-CC-AMA FPL7616235R2123 40 IORR3800-30 FPL6615001R2113 24 FPL8716195R2113 38 IORR200-20-MT FPL7625215R2113 25 IORR3800-30-CC FPL6616001R2113 38 IORR1000-10-CC-U FPL8716195R2113 39 IORR200-20-MT-AMA FPL7625235R2123 27 IORR3800-30-MT FPL6625001R2113 25 IORR1000-20 FPL8715215R2113 24 IORR200-30-CC On request 38 IORR3800-30-MT-AME FPL6625325R2123 27 IORR1000-20-AME FPL8715225R2223 26 IORR200-30-CC-AMA On request 40 IORR400-10-CC FPL9416115R2113 38 IORR1000-20-CC FPL8716215R2113 38 IORR200-30-MT FPL7625315R2113 25 IORR400-10-CC-AME FPL9416125R2223 40 IORR1000-20-CC-AME FPL8716225R2223 40 IORR200-30-MT-AMA FPL7625335R2123 27 IORR400-20-CC FPL9416215R2113 38 IORR1000-30 FPL8715315R2113 24 IORR200-40-MT FPL7625415R2113 25 IORR400-20-CC-AME FPL9416225R2223 40 IORR1000-30-AME FPL8715325R2223 26 IORR200-40-MT-AMA FPL7625435R2123 27 IORR400-20-MT FPL9425215R2113 25 IORR1000-30-CC FPL8716315R2113 38 IORR2100-10-CC-AME FPL6316125R2223 40 IORR400-20-MT-AME FPL9425225R2123 27 IORR1000-30-CC-AME FPL8716325R2223 40 IORR2100-10-CC-U FPL6316195R2113 38 IORR400-30-CC On request 38 IORR1000-40 FPL8715415R2113 24 IORR2100-10-CC-U FPL6316195R2113 39 IORR400-30-CC-AME FPL9416325R2223 40 CONTACT SET WITH ARCING HORN FPTN410506R0001 80 EQUIPOTENTIAL CONNECTION FPTN410176R0006 81 EQUIPOTENTIAL CONNECTION FPTN410176R0007 81 IORR1000-10-CC-AME FPL8716125R2223 IORR1000-10-CC-U 1SXU10607C0201 | R contactor US catalog Index Type classification Type Order code Page Type Order code Page Type Order code Page IORR400-30-MT FPL9425315R2113 25 LORR1400-20 FPL6135210R2113 55 NORR125-02-CC FPL7446215R2113 50 IORR400-30-MT-AME FPL9425325R2123 27 LORR1400-30 FPL6135310R2113 55 NORR125-02-MT FPL7455215R2113 49 IORR400-40-MT FPL9425415R2113 25 LORR1400-40 FPL6135410R2113 55 NORR125-21-CC FPL7446515R2113 50 IORR4500-10-CC FPL6816115R2113 38 LORR1700-10 FPL6235110R2113 55 NORR125-21-MT FPL7455515R2113 49 IORR4500-10-CC-AME FPL6816125R2223 40 LORR1700-20 FPL6235210R2113 55 IORR4500-20 FPL6815215R2113 24 LORR1700-30 FPL6235310R2113 55 IORR4500-20-AME FPL6815225R2223 26 LORR1700-40 FPL6235410R2113 55 IORR4500-20-CC FPL6816215R2113 38 LORR170-10 FPL7535110R2113 55 IORR4500-20-CC-AME FPL6816225R2223 40 LORR170-20 FPL7535210R2113 55 NORR125-31-CC FPL7446715R2113 50 NORR125-31-MT FPL7455715R2113 49 NORR200-01-CC FPL7646115R2113 50 NORR200-02-CC FPL7646215R2113 50 FPL7655215R2113 49 IORR4500-20-MT FPL6825215R2113 25 LORR170-30 FPL7535310R2113 55 NORR200-02-MT IORR4500-20-MT-AME FPL6825225R2123 27 LORR170-40 FPL7535410R2113 55 NORR200-21-CC FPL7646515R2113 50 IORR4500-30 FPL6815001R2113 24 LORR2100-10 FPL6335110R2113 55 NORR200-21-MT FPL7655515R2113 49 IORR4500-30-CC FPL6816001R2113 38 LORR2100-20 FPL6335210R2113 55 NORR200-31-CC FPL7646715R2113 50 IORR4500-30-MT FPL6825002R2113 25 LORR2100-30 FPL6335310R2113 55 NORR200-31-MT FPL7655715R2113 49 IORR500-10-CC FPL8316115R2113 38 LORR2100-40 FPL6335410R2113 55 NORR400-01 FPL9445115R2113 50 IORR500-10-CC-AME FPL8316125R2223 40 LORR2500-10 FPL6735110R2113 55 IORR500-20-CC FPL8316215R2113 38 NORR400-02 FPL9445215R2113 49 LORR2500-20 FPL6735210R2113 55 LORR2500-30 FPL6735310R2113 55 NORR400-02 FPL9445215R2113 50 NORR400-21 FPL9445515R2113 49 NORR400-21 FPL9445515R2113 50 49 IORR500-20-CC-AME FPL8316225R2223 40 IORR500-20-MT FPL8325215R2113 25 IORR500-20-MT-AME FPL8325225R2123 27 LORR260-10 FPL7835110R2113 55 IORR500-30-CC On request 38 LORR260-20 FPL7835210R2113 55 NORR400-31 FPL9445715R2113 IORR500-30-CC-AME FPL8316325R2223 40 LORR260-30 FPL7835310R2113 55 NORR400-31 FPL9445715R2113 50 IORR500-30-MT FPL8325315R2113 25 LORR260-40 FPL7835410R2113 55 NORR63-01-CC FPL7146116R2113 50 IORR500-30-MT-AME FPL8325325R2123 27 LORR3200-10 FPL6535110R2113 55 NORR63-02-CC FPL7146216R2113 50 IORR500-40-MT FPL8325415R2113 25 LORR3200-20 FPL6535210R2113 55 NORR63-02-MT FPL7155216R2113 49 NORR63-21-CC FPL7146516R2113 50 NORR63-21-MT FPL7155516R2113 49 LORR2500-40 FPL6735410R2113 55 IORR5100-10-CC FPL6916115R2113 38 LORR3200-30 FPL6535310R2113 55 IORR5100-10-CC-AME FPL6916125R2223 40 LORR3200-40 FPL6535001R2113 55 IORR5100-20 FPL6915001R2113 24 LORR3800-10 FPL6635110R2113 55 IORR5100-20-CC FPL6916002R2113 38 LORR3800-20 FPL6635210R2113 55 IORR5100-20-MT FPL6925001R2113 25 LORR3800-30 FPL6635002R2113 55 IORR5100-30 FPL6915002R2113 24 LORR3800-40 FPL6635003R2113 55 IORR5100-30-CC FPL6916001R2113 38 LORR400-10 FPL9435110R2113 55 IORR5100-30-MT FPL6925002R2113 25 LORR400-20 FPL9435210R2113 IORR63-10-CC FPL7116116R2113 38 LORR400-30 FPL9435310R2113 IORR63-10-CC-AMA FPL7116136R2123 40 LORR400-40 FPL9435410R2113 IORR63-20-CC FPL7116216R2113 38 LORR4500-10 IORR63-20-CC-AMA FPL7116236R2123 40 IORR63-20-MT FPL7125216R2113 25 IORR63-20-MT-AMA FPL7125236R2123 27 IORR63-30-CC On request 38 IORR63-30-CC-AMA On request 40 IORR63-30-MT FPL7125386R2113 25 IORR63-30-MT-AMA FPL7125336R2123 27 IORR63-40-MT FPL7125416R2113 25 IORR63-40-MT-AMA FPL7125436R2123 27 IORR800-10-CC-AME FPL8616125R2223 40 IORR800-10-CC-U FPL8616195R2113 38 IORR800-10-CC-U FPL8616195R2113 39 IORR800-20 FPL8615215R2113 24 IORR800-20-AME FPL8615225R2223 26 IORR800-20-CC FPL8616215R2113 38 IORR800-20-CC-AME FPL8616225R2223 40 IORR800-20-MT FPL8625215R2113 25 IORR800-20-MT-AME FPL8625225R2123 27 IORR800-30 FPL8615315R2113 24 IORR800-30-AME FPL8615325R2223 26 IORR800-30-CC FPL8616315R2113 38 IORR800-30-CC-AME IORR800-30-MT FPL8616325R2223 FPL8625315R2113 40 25 NORR63-31-CC FPL7146716R2113 50 NORR63-31-MT FPL7155716R2113 49 NORR800-01-CC FPL8646115R2113 50 NORR800-02 FPL8645215R2113 49 55 NORR800-02-CC FPL8646215R2113 50 55 NORR800-02-MT FPL8655215R2113 49 55 NORR800-21 FPL8645515R2113 49 FPL6835110R2113 55 NORR800-21-CC FPL8646515R2113 50 LORR4500-20 FPL6835210R2113 55 NORR800-21-MT FPL8655515R2113 49 LORR4500-30 FPL6835001R2113 55 NORR800-31 FPL8645715R2113 49 LORR5100-10 FPL6935110R2113 55 NORR800-31-CC FPL8646715R2113 50 LORR5100-20 FPL6935001R2113 55 LORR550-10 FPL8435110R2113 55 NORR800-31-MT FPL8655715R2113 49 RECTIFIER BRIDGE TRE2614501 82 TRE2720806 82 LORR550-20 FPL8435210R2113 55 LORR550-30 FPL8435310R2113 55 RECTIFIER BRIDGE LORR550-40 FPL8435410R2113 55 RV-R1/133 FPTN410463R6002 82 LORR800-10 FPL8635110R2113 55 RV-R1/250 FPTN410463R6003 82 LORR800-20 FPL8635210R2113 55 RV-R1/440 FPTN410463R6004 82 LORR800-30 FPL8635310R2113 55 RV-R1/60 FPTN410463R6001 82 LORR800-40 FPL8635410R2113 55 RV-R1/660 FPTN410463R6005 82 LORR85-10 FPL7235110R2113 55 LORR85-20 FPL7235210R2113 55 SHAFT EXTENSION R200… R420 FPTN410111R0002 84 LORR85-30 FPL7235310R2113 55 LORR85-40 FPL7235410R2113 55 SHAFT EXTENSION R400, 500 550 FPTN410111R0003 84 82 SHAFT EXTENSION R63… R170 FPTN410111R0001 84 MAGNET SET FOR MAIN COIL FPTN410437R0001 MAGNET SET FOR MAIN COIL FPTN410438R0001 82 UNIVERSAL MOUNTING KIT FPTN410054R0016 77 MAGNET SET FOR MAIN COIL FPTN410439R0001 82 VM15-SP FPL8301401R0002 83 VM16 FPL8601401R0001 83 FPL8801401R0001 83 MAGNET SET FOR MAIN COIL FPTN410441R0001 82 VM17/18 IORR800-30-MT-AME FPL8625325R2123 27 IORR800-40 FPL8615415R2113 24 MAGNET SET FOR MAIN COIL FPTN410200R0006 82 VM19 FPL9001401R0001 83 FPTN410054R0017 77 VM21/24 FPL7101403R0001 83 IORR800-40-AME FPL8615425R2223 26 MOUNTING KIT IORR800-40-MT FPL8625415R2113 25 MOUNTING KIT FPTN410213R0006 77 VM25 FPL7401404R0001 83 LORR1400-10 FPL6135110R2113 55 NORR125-01-CC FPL7446115R2113 50 VM27 FPL8001401R0001 83 R contactor US catalog | 1SXU106047C0201 12 135 Notes 136 1SXU10607C0201 | R contactor US catalog ABB Low Voltage Products 8155 T&B Boulevard Memphis, TN 38125 www.abb.us/lowvoltage USA Technical Support: 888-385-1221 Customer Service: 888-862-3290 7:00 a.m.-5:30 p.m., CST, Monday-Friday lvps.support@us.abb.com R contactors www.abb.com/lowvoltage Note We reserve the right to make technical changes or modify the contents of this document without prior notice. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents – in whole or in parts – is forbidden without prior written consent of ABB. Copyright © 2015 ABB - All rights reserved 1SXU106047C0201 - Printed in US July 2015 Contact us
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Author : USDOTHU Create Date : 2015:07:08 09:26:13-05:00 Modify Date : 2015:07:09 11:46:53-05:00 XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Producer : Acrobat Distiller 15.0 (Windows) Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2015:07:09 11:46:53-05:00 Format : application/pdf Title : R-Contactor.indb Creator : USDOTHU Document ID : uuid:081809fc-72f2-4b46-a82f-668e90905cd1 Instance ID : uuid:7f054e61-1790-41d0-9e1b-2f0fcb5a9a30 Page Count : 137EXIF Metadata provided by EXIF.tools