SIMATIC HMI / PC Based Automation Operator Control And Monitoring Systems 1000471964 Catalog
2016-10-06
: Pdf 1000471964-Catalog 1000471964-Catalog B5 unilog
Open the PDF directly: View PDF .
Page Count: 676
Download | |
Open PDF In Browser | View PDF |
© Siemens AG 2013 Human Machine Interface Systems/ PC-based Automation SIMATIC HMI / PC-based Automation Catalog ST 80/ ST PC Edition 2013 Answers for industry. SO_Umschlag_KG_ST80_STPC_2013_en.indd 3 05.08.2013 13:48:25 © Siemens AG 2013 Related catalogs SIMATIC Products for Totally Integrated Automation ST 70 E86060-K4670-A101-B4-7600 Industrial Communication SIMATIC NET IK PI E86060-K6710-A101-B7-7600 SITOP Power supply SITOP KT 10.1 E86060-K2410-A111-A9-7600 SITRAIN Training for Automation and Industrial Solutions ITC Only available in German E86060-K6850-A101-C3 Products for Automation and Drives Interactive Catalog, DVD E86060-D4001-A510-D2-7600 Mall Information and Ordering Platform in the Internet: www.siemens.com/industrymall CA 01 © Siemens AG 2013 SIMATIC HMI / PC-based Automation Operator Control and Monitoring Systems Introduction 1 Operator panels 2 HMI devices for special requirements 3 HMI Software 4 PC-based Automation 5 Customized Automation 6 Appendix 7 Catalog ST 80 / ST PC · 2013 The products and systems described in this catalog are manufactured/distributed under application of a certified quality management system in accordance with DIN EN ISO 9001 (Certified Registration No. 2613-05). The certificate is recognized by all IQNet countries. Supersedes: Catalog ST 80 / ST PC · 2012 Refer to the Industry Mall for current updates of this catalog: www.siemens.com/industrymall The products contained in this catalog can also be found in the Interactive Catalog CA 01. Order No.: E86060-D4001-A510-D2-7600 Please contact your local Siemens branch. © Siemens AG 2013 Printed on paper from sustainably managed forests and controlled sources. www.pefc.org © Siemens AG 2013 2 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Answers for industry. Integrated technologies, vertical market expertise and services for greater productivity, energy efficiency, and flexibility. The Siemens Industry Sector is the world's leading supplier of innovative and environmentally friendly products and solutions for industrial companies. End-to-end automation technology and industrial software, solid market expertise, and technology-based services are the levers we use to increase our customers’ productivity, efficiency and flexibility. With a global workforce of more than 100 000 employees, the Industry Sector comprises the Industry Automation, Drive Technologies, and Customer Services divisions, as well as the Metals Technologies Business Unit. We consistently rely on integrated technologies and, thanks to our bundled portfolio, we can respond more quickly and flexibly to our customers' wishes. With our globally unmatched range of automation technology, industrial control and drive technology as well as industrial software, we equip companies with exactly what they need over their entire value chain – from product design and development to production, sales and service. Our industrial customers benefit from our comprehensive portfolio, which is tailored to their market and their needs. Market launch times can be reduced by up to 50% due to the combination of powerful automation technology and intelligent industrial software from Siemens Industry. At the same time, the costs for energy or waste water for a manufacturing company can be reduced significantly. In this way, we increase our customers’ competitive strength and make an important contribution to environmental protection with our energy-efficient products and solutions. Siemens ST 80 / ST PC · 2013 3 © Siemens AG 2013 (53²(QWHUSULVH5HVRXUFH3ODQQLQJ 3/0²3URGXFW/LIHF\FOH0DQDJHPHQW 0DQDJHPHQW/HYHO 3URGXFW'HVLJQ 3URGXFWLRQ3ODQQLQJDQG6LPXODWLRQ 'DWD0DQDJHPHQW 0(6²0DQXIDFWXULQJ([HFXWLRQ6\VWHPV 6,0$7,&,7 2SHUDWLRQV/HYHO 0DLQWHQDQFH $VVHW0DQDJHPHQW 6,0$7,&3&6 2SHUDWRU6\VWHP (QHUJ\ 0DQDJHPHQW (QJLQHHULQJ 6WDWLRQ 7,$3RUWDO &RQWURO/HYHO 6,0$7,&3&6 $XWRPDWLRQ 6\VWHPV 6,180(5,. &RPSXWHU1XPHULF&RQWURO 6,027,21 0RWLRQ&RQWURO 6,0$7,&1(7 ,QGXVWULDO &RPPXQLFDWLRQ 6,0$7,&&RQWUROOHUV 0RGXODU3&EDVHG )LHOG/HYHO 352),%863$ 3URFHVV,QVWUXPHQWDWLRQ 7RWDOO\ ,QWHJUDWHG $XWRPDWLRQ 6,0$7,&'LVWULEXWHG,2 6,0$7,&,GHQW ,QGXVWULDO,GHQWLÀFDWLRQ +$57 ,2/LQN Setting standards in productivity and competitiveness. Totally Integrated Automation. 4 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 TIA is characterized by its unique continuity. It provides maximum transparency at all levels with reduced interfacing requirements – covering the field level, production control level, up to the corporate management level. With TIA you also profit throughout the complete life cycle of your plant – starting with the initial planning steps through operation up to modernization, where we offer a high measure of investment security resulting from continuity in the further development of our products and from reducing the number of interfaces to a minimum. 3ODQW(QJLQHHULQJ &2026 (WKHUQHW 6,0$7,&:LQ&& 6&$'$6\VWHP The unique continuity is already a defined characteristic at the development stage of our products and systems. ,QGXVWULDO(WKHUQHW 6,0$7,&+0, +XPDQ0DFKLQH,QWHUIDFH The result: maximum interoperability – covering the controller, HMI, drives, up to the process control system. This reduces the complexity of the automation solution in your plant. You will experience this, for example, in the engineering phase of the automation solution in the form of reduced time requirements and cost, or during operation using the continuous diagnostics facilities of Totally Integrated Automation for increasing the availability of your plant. 6,5,86,QGXVWULDO&RQWUROV 352),1(7 ,QGXVWULDO(WKHUQHW 352),%86 6,1$0,&6'ULYH6\VWHPV 6,7233RZHU6XSSO\ $6,QWHUIDFH .1;*$00$LQVWDEXV /RZ9ROWDJH'LVWULEXWLRQ 7RWDOO\ ,QWHJUDWHG 3RZHU 6,027,&60RWRUV Thanks to Totally Integrated Automation, Siemens provides an integrated basis for the implementation of customized automation solutions – in all industries from inbound to outbound. Siemens ST 80 / ST PC · 2013 5 © Siemens AG 2013 Totally Integrated Power: Future-proof power supply from one source. 6 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Software tools, products, systems and support for integrated electrical power distribution Energy Management/ Energy Transparency Operation & Monitoring Load management Load curves Forecast Maintenance Substation Distribution Maintenance task Status reporting/ failure management Protocols Power Quality DATE: Cost center EMPLOYEE COST CENTER PAY PERIOD BEGINNING PAY PERIOD ENDING DATE SUN MON TUE WED THUR FRI SUN MON TUE WED THUR FRI SAT SUN TOTAL IN OUT IN OUT OVERTIME TOTAL HOURS DATE SAT SUN TOTAL IN OUT U I cos o P W IN Hall 1 Distribution 3 Process/ industrial automation Products & Systems Infeed II Renewables Medium voltage with protection technology Air conditioning system checkup Replacing circuit breaker contacts Replacing meters OUT OVERTIME TOTAL HOURS central ON OFF local ON OFF tripped Transformer DATE SUN MON TUE WED THUR FRI SAT SUN TOTAL IN OUT IN OUT Building automation OVERTIME TOTAL HOURS Low voltage with protection and measuring technology ≤ 110 kV Planning Software Tools The power supply system acts like a “vital artery”, forming the basis for the reliable and efficient functioning of all electrically operated building installations. Electrical power distribution therefore requires integrated solutions. Our answer: Totally Integrated Power (TIP). This includes software tools and support for planning and configuration and a complete, optimally aligned product and system portfolio for integrated power distribution from medium-voltage switchgear right to socket outlets. Network dimensioning with SIMARIS design Space requirements and budget calculation with SIMARIS project The power distribution products and systems can be interfaced to building or industrial automation systems (Total Building Solutions or Totally Integrated Automation) via communication-capable circuit breakers and components, allowing the full potential for optimization that an integrated solution offers to be exploited throughout the project cycle – from planning right through to installation and operation. Visualization of device characteristics with SIMARIS curves Get more information: www.siemens.com/tip www.siemens.com/simaris www.siemens.com/specifications Siemens ST 80 / ST PC · 2013 7 © Siemens AG 2013 8 Siemens ST 80 / ST PC · 2013 1 © Siemens AG 2013 Operator control and monitoring systems / PC-based Automation 1/2 1/2 1/8 Introduction SIMATIC HMI operator control and monitoring systems SIMATIC PC-based Automation Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Introduction Gain transparency and lower costs 1 SIMATIC HMI operator control and monitoring systems ■ Overview The interface between human and machine – the human machine interface or HMI for short – connects the world of automation with the individual requirements of the operator. Human machine interfacing is about managing the process, optimizing machine and system operation, availability and productivity. 1/2 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Introduction Gain transparency and lower costs SIMATIC HMI operator control and monitoring systems ■ Overview (continued) Everything from a single source Integrated into the World Wide Web With SIMATIC HMI, Siemens Automation and Drives offers a complete range of innovative and low-cost products and systems for the multi-faceted tasks of operator control and monitoring: Ranging from operator panels and visualization software for operator control and monitoring at the machine through to SCADA systems for widely differing requirements in process visualization. For special requirements, optimally adapted products are offered such as especially rugged HMI devices with all-round protection for mounting on support arms/ pedestals, or operator panels with stainless steel front for use in the food and beverages industry. Of course, individual, customer-specific requirements can also be implemented. SIMATIC HMI makes the Internet into a control desk - within a plant as well as in the worldwide network. Perfectly equipped for integration in the world of automation With their open, standardized interfaces in hardware and software, SIMATIC HMI products can be integrated at any time in the production and automation level as well as in the company management level. Connectability to almost every controller on the market as well as multiple language capability of the configuration and visualization software – including Asian ideographic languages, of course – facilitate operation worldwide. Using the WinCC/Web Navigator, you can monitor and operate plants over the Internet or over the internal corporate intranet. Thin client solutions can be used to integrate rugged, local devices which simultaneously establish the connection between the automation level and the control center. And over a wireless LAN or cell phone connection, you can use mobile thin clients such as laptop computers, PDAs (personal digital assistants) or WebPads. In this way, process, service or management information can be made individually available to users. At the machine level, many control units support remote operation, e.g. as a link between the automation level and the control room through to service and diagnostics over the Internet. For operation and monitoring at the machine, concepts with socalled Sm@rtClients and servers facilitate plant-wide access to variables and graphics, distributed operator stations as well as remote operation and diagnostics via the Internet – also in conjunction with SIMATIC Panels. www.siemens.com/simatic-hmi Increased production transparency through Plant Intelligence Plant Intelligence is based on the intelligent utilization of information to improve processes within the company. It is designed to lower plant costs, consolidate and improve quality, avoid wastage, utilize production facilities better and ultimately ensure greater efficiency and cost effectiveness within the company. WinCC provides the best requirements for achieving this since WinCC features an integrated Historian for acquiring important production data. Using intelligent functions and tools, this process data can be edited into information necessary for making decisions and can be made available throughout the company whenever and wherever it is required – for operators as well as production managers or anyone else within the company. Even the WinCC basic system provides a wealth of display and evaluation functions, such as the statistics function for the message and measured value logs. WinCC options for IT & business integration make additional "smart" tools available for optimizing production using Plant Intelligence. Siemens ST 80 / ST PC · 2013 1/3 1 © Siemens AG 2013 Introduction Gain transparency and lower costs 1 SIMATIC HMI operator control and monitoring systems ■ Overview (continued) Traceability and easy validation More than just operator control and monitoring SIMATIC HMI software with "FDA options" provides a high degree of support to machine and plant manufacturers who must fulfill high quality requirements, both with respect to the products to be manufactured as well as to the manufacturing processes themselves. The Multi Panels under Windows CE combine the advantages of two worlds: On the one hand, the ruggedness of an operator panel and on the other hand the flexibility typical of a PC. These options simplify plant validation enormously and thus provide the most convincing and comprehensive solution for the requirements of these industries. They support the user in fulfilling high quality requirements as specified by the FDA (Food and Drug Administration) 21 CFR Part 11 for the food, beverages and pharmaceutical industries. Increased plant availability All operator panels and Panel PCs are designed for harsh industrial use. Redundant process visualization systems ensure a high degree of plant availability during normal operation. Distributed operator control concepts SIMATIC HMI offers different solutions for different requirements for operator control of large machines and plants spread over extensive areas. Thus, the Sm@rtAccess option of the SIMATIC WinCC flexible visualization software, for example, allows HMI devices such as panels, Thin Clients and PCs plant-wide access via PROFINET/ Ethernet to current process values and the local screen images of all involved stations. SIMATIC HMI software offers appropriate options for diagnostics, maintenance and telecontrol over the Internet from local operator stations. As remote operator stations, SIMATIC Thin Clients make the functionality of machine-level panels available in the control room or in the office, thanks to their connection to PROFINET/ Ethernet, and in the other direction, they bring SIMATIC WinCC or office or IT functionality straight to the machine. In PC-based applications, a SIMATIC Flat Panel monitor can take over the function of the operating unit from PCs, such as SIMATIC Rack or Box PC, at a distance of up to 30 m. 1/4 Siemens ST 80 / ST PC · 2013 Apart from classical operator control and monitoring, other automation functions such as control functions can execute simultaneously. And for PC-based automation, the SIMATIC Panel PCs are available as a compact automation platform - the embedded versions being especially compact and rugged as well as maintenance-free. © Siemens AG 2013 Introduction Gain transparency and lower costs SIMATIC HMI operator control and monitoring systems ■ Overview (continued) All the advantages of Totally Integrated Automation Investment protection is included With Totally Integrated Automation (TIA), Siemens is the only supplier who offers a system-wide, integrated product and system range for automating the complete production workflow. The distinguishing feature of TIA is that it is completely integrated. The reduced number of interfaces results in very clear structures. Our many years of experience in the automation engineering sector are to your advantage. The same applies to our global service network with its expert support. Further services, such as a software update service, training, ordering over the Internet, etc. round off what we have to offer. This reduces time and costs required for engineering the automation solution and increases the availability of the plant. In conjunction with other SIMATIC components, SIMATIC HMI also supports system diagnostics and process diagnostics during normal operation. You can start STEP 7 diagnostics directly from WinCC for comprehensive error diagnostics from the circuit diagram through to the PLC program. The SIMATIC Maintenance Station visualizes the maintenance information for the automation technology of a system – from the controller and network components to switchgear, protective equipment and control devices and the drives. This gives a clear overview of the status of the automation at any time. A competent partner for automation solutions With SIMATIC HMI, you not only get excellent products to suit your requirements, we will also support you when selecting a partner for your automation solution. In our worldwide network of Siemens Automation Solution Partners, you will find competent contact partners in your area who are always up-to-date with SIMATIC HMI technology. The Siemens-internal WinCC Competence Centers implement technology-specific products as well as customer and industryspecific solutions on the basis of WinCC. WinCC specialists are external system integrators who combine their WinCC expertise with their industry and technology knowhow to create tailor-made, cost-effective solutions. Numerous products from our partners that perfectly interact with WinCC are available as WinCC Add-ons. Siemens ST 80 / ST PC · 2013 1/5 1 © Siemens AG 2013 Introduction A whole world of operator control and monitoring 1 SIMATIC HMI operator control and monitoring systems SIMATIC® HMI® HMI devices SIMATIC HMI Key Panels Operator panels with bus capability for easy and direct operation of machines. www.siemens.com/key-panels SIMATIC HMI Basic Panels Operator panels with basic functionality for low-cost operator control and monitoring of simple applications. www.siemens.com/basic-panels Process visualization Single-user PC SIMATIC HMI Comfort Panels HMI devices with high-end functionality for demanding applications. www.siemens.com/comfort-panels SIMATIC HMI Mobile Panels Mobile operator panels with or without cables for direct operator control of the plant and machine from any location. www.siemens.com/simatic-mobile-panels HMI devices for special requirements Operator control and monitoring directly at the machine Key Panels Basic Panels Fully enclosed HMI devices for SIMATIC The fully enclosed SIMATIC HMI devices (MP 377 PRO, HMI IPC477C PRO, Flat Panel PRO and Thin Client PRO) are ideal for industrial applications in harsh environments due to their extremely robust design. They are, for example, specially designed for mounting on a support arm/stand. www.siemens.com/ip65-hmi-devices Devices with stainless steel fronts Panels and Panel PCs with touch screens and stainless steel fronts are designed for machine-level operator control and monitoring in the food, beverages and tobacco industry. www.siemens.com/inox-hmi-devices SIMOTION Motion Control HMI devices for hazardous areas Intrinsically safe Panel PCs and Thin Clients that were specifically developed for hazardous areas. www.siemens.com/simatic-hmi-ex HMI software Flexibility in any HMI application – from Basic Panels through to process visualization Actuators / Sensors SIMATIC WinCC in the Totally Integrated Automation Portal (TIA Portal) is part of a new, integrated engineering framework which offers a uniform engineering environment for programming and configuration of control, visualization and drive solutions. WinCC in the TIA Portal is the software for all HMI applications ranging from the simplest operation solutions with Basic Panels to SCADA applications on PC-based multi-user systems. www.siemens.com/tia-portal SIMATIC WinCC V7 remains available for extremely complex applications featuring Plant Intelligence solutions, integrated archive servers or redundant architectures, whereas WinCC Open Architecture addresses applications with demanding customization requirements, also on non-Windows platforms. www.siemens.com/wincc WinCC Open Architecture adressiert Anwendungen mit hohem kundenspezifischen Anpassungsbedarf – auch auf Nicht-Windows-Plattformen. www.siemens.com/wincc-open-architecture 1/6 Siemens ST 80 / ST PC · 2013 Customized Automation With Customized Automation, field-proven SIMATIC, SIMATIC IPC and SIMATIC HMI standards are transferred to individual products and systems – tailored precisely to the customer's requirements. The portfolio covers the hardware and software range, as well as support and logistics. www.siemens.com/customized-automation © Siemens AG 2013 Introduction A whole world of operator control and monitoring SIMATIC HMI operator control and monitoring systems Enterprise Resource Planning (ERP) Manufacturing Execution Systems (MES) Plant Intelligence Internet client Client/Server Panel PCs Flat Panel monitors Mobile Panels SIMATIC Controller S7-200 S7-1200 Field devices S7-400 Software HMI WinCC (TIA Portal) Thin Clients Additional automation systems S7-300 Drives G_ST80_XX_00365 Comfort Panels SCADA system WinCC Siemens ST 80 / ST PC · 2013 1/7 1 © Siemens AG 2013 Introduction ■ Overview SIMATIC Thin Client SIMATIC WinCC Visualization Archive Databases SIMATIC Field PG Configuration Programming STEP 7 PROFINET Industrial Ethernet SIMATIC S7 SIMATIC Panel PC WinCC, WinAC Software PLC SIMATIC Rack PC SIMATIC Box PC Nanobox PC/Microbox PC WinAC (F) Software PLC WinAC (F) Software PLC SIMATIC Embedded Bundles: IPC2x7D/IPC4x7C S7-modular Embedded Controller PROFINET PROFIBUS SIMATIC HMI Panel Operator control and monitoring ET 200 SIMOTION D / SINAMICS / MICROMASTER G_ST70_XX_00169 1 SIMATIC PC-based Automation SIMATIlC PC-based Automation Embedded bundles with industrial PCs www.siemens.com/pc-based Embedded bundles based on the embedded industrial PCs are extremely compact, robust, and maintenance-free systems for use at machine level. The functions PC-based Control (also failsafe) and/or visualization are already pre-installed and ready to use. Industrial PCs Our reliable and innovative industrial PCs are the optimal PC hardware platform for PC-based Automation from Siemens. www.siemens.com/simatic-ipc PC-based controllers www.siemens.com/simatic-embedded-bundles Software packages for SIMATIC IPCs Siemens has developed a wide range of coordinated hardware and software components for PC-based Automation. Focal point: SIMATIC PC-based Control with SIMATIC WinAC, the open, flexible and reliable software controller for your PC-based automation solution, also approved by the German Technical Inspectorate and fail-safe. SIMATIC industrial PCs are offered with low-cost software packages. For the runtime versions with the visualization software products SIMATIC WinCC or WinCC Professional, WinCC flexible or WinCC Advanced, as well as the software controller SIMATIC WinAC RTX (F). The simultaneous purchase of industrial PC and software package results in the price advantage. www.siemens.com/winac www.siemens.com/simatic-ipc-packages Embedded controllers Industrial monitors and thin clients SIMATIC S7-mEC is a modular controller in S7-300 design with the latest embedded PC technology. It comprises the EC31 (CPU) as well as the optionally available expansion modules. Flexible distributed operating concepts can be implemented via Flat Panel monitors and thin clients. These are industry-standard LCD monitors with high-luminance displays that are placed up to 30 m away from the PC, or high-performance industrial thin clients. SIMATIC ITC, for one or even several operator stations, can be placed as far away as required via Industrial Ethernet. www.siemens.com/simatic-s7-mec www.siemens.com/simatic-ifp www.siemens.com/simatic-itc 1/8 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Introduction SIMATIC PC-based Automation ■ Overview (continued) Measurement of foil thickness Application examples www.siemens.com/pc-based-applications During the manufacture of plastic films, a highly accurate and uniform foil thickness over the entire width is a decisive quality criterion. For this purpose, a measuring head with radioactive source moves back and forth above the film and perpendicular to the continuously transported reel, and a sensor moves underneath the foil. Unit-type cogeneration unit When redesigning unit-type cogeneration units, the automation approach should also be restructured. The objective was to execute all control, visualization and archiving tasks which were previously handled by a PLC and a PC on a compact unit. Space was to be saved in the control cabinet, and the administration and training requirements reduced. At the same time a rugged, maintenancefree device was required which can also be easily connected over the Internet. The advantages of the solution with SIMATIC PC-based Automation: • Microbox PC IPC427C as a rugged, compact embedded system - Control, visualization and archiving of the process parameters in one device - Space and cost savings thanks to integration of several tasks on a single embedded industrial PC Previously: one PLC and one visualization PC • Easy and quick access to the embedded IPC over the Internet Router E-mail SIMATIC HMI IPC577 Remote control station 2 x ET 200S with motor starter 2 x ET 200S DI/DO The advantages of the solution with SIMATIC PC-based Automation: • Visualization is performed using WinCC, and control using WinAC RTX on a PC. • Complex mathematical algorithms are required for evaluation of the extensive measured data. • These are meaningfully implemented in the high-level language C++. Seamless and high-performance integration of these algorithms into the STEP 7 program is via the ODK (Open Development Kit). • Data exchange between WinAC RTX and WinCC, for visualization of the extensive measured curves, takes place very quickly via the hard drive cache. This functionality was also implemented via the ODK. • Interconnection of the standardized technology function is via CFC (Continuous Function Chart). WinCC WinAC RTX Visual C++ CP 5613 A2 Analysis of the measured data The plant concept ET 200M Drive PROFIBUS G_ST80_XX_00431 Embedded IPC Microbox PC IPC427 Internet/ telephone network G_ST80_XX_00430 Industrial Ethernet From the attenuation of the radiation, the foil thickness can be determined exactly at each position by extensive mathematical calculations, and deviations from the reference thickness can be compensated. The plant concept Siemens ST 80 / ST PC · 2013 1/9 1 © Siemens AG 2013 Introduction ■ Overview (continued) PC-based control of paint shops for plastic automotive parts For reasons of quality assurance and product liability, paint shop manufacturers are obliged to use a host computer for archiving the process data of a paint shop for flat parts, but this quickly developed into a PCbased automation system with control tasks. The advantages of the solution with SIMATIC PC-based Automation: • Performance of the SIMATIC WinAC PC-based control. • Coupling to Linux servers through an Industrial Ethernet fiberoptic network. • Open and flexible for expansions. • Possibility of integration into the existing automation concept. • Archiving and backup of process data, as well as production data acquisition. Linux Server FOC Ethernet Rack PC IPC847 WinAC RTX WinCC flexible PROFIBUS DP HMI Panel ET 200M S7-314 S7-314 HMI Panel MPI DP Frequency converter TP 177 HMI Panel The plant concept 1/10 Siemens ST 80 / ST PC · 2013 VS 710 G_ST80_XX_00432 1 SIMATIC PC-based Automation Innovative PC-based solution with safety for solar panel production For a new plant for the production of solar panels, the existing highly heterogeneous concept is to be replaced by a new, state-of-the-art automation solution which can cover the comprehensive demands in a compact and integrated way. There are increased performance and memory requirements due to the increased complexity of the system. The PLC should also be able to provide the specified safety functions (emergency stop, access protection to hazardous areas). Various bus systems must be linked in plant 3. Also a customerspecific Windows application is to be used on the selected systems and therefore the connection to a higher-level MES system has to be implemented. The system is designed for high throughput and three-shift operation. The advantages of the solution with SIMATIC PC-based Automation: • Very high performance and available memory with the SIMATIC Modular Embedded Controller EC31-RTX F. In the RTX F version (worldwide the first software PLC with safety functionality), the EC31 offers full coverage of all safety requirements in the plant. This system is integrated seamlessly in Totally Integrated Automation and enables effective, plant-wide engineering. • Thanks to its openness (Open Development Kit), WinAC RTX on the host SCADA industrial PC offers the possibility for integrating a Windows customer application with very little effort, and is thus used as a data concentrator (process quality/diagnostic data), and communication with the host MES system is also implemented in combination with WinCC (SCADA). • Industry-standard products from the SIMATIC range offer maximum quality for 24/7 round the clock operation. © Siemens AG 2013 Introduction SIMATIC PC-based Automation ■ Overview (continued) PC-based machine data acquisition optimizes the production of farming machinery Safe transfer at sea For transferring persons at sea to wind energy plants or oil platforms, a Dutch company has developed a six-legged platform on hydraulic cylinders. This platform is basically an upside-down flight simulator, and allows safe transfer from a ship even in bad weather. To introduce more efficient, resource-saving and therefore cost-effective production processes in the factory, a leading farming machinery manufacturer has integrated a central, plant-wide machine data acquisition system using Panel PCs. Due to the need for retrofitting in the existing environment, flexible and space-saving installation of the Panel PCs was paramount. A SIMATIC S7 modular embedded controller (S7-mEC) with fast I/O cards measures the movements of the ship and controls the extending or retracting of the cylinders so that all movements are compensated. More than 200 fully enclosed SIMATIC HMI IPC477C PRO Panel PCs for central machine data acquisition with communications interfacing to the production machines and the production planning computer. Mounting of the Panel PCs directly at the machine without additional control boxes on stand-alone columns. The advantages of the solution with SIMATIC PC-based Automation: • Fault-tolerant SIMATIC S7-400H in redundant design for general control tasks. • Two lower-level SIMATIC S7 modular embedded controllers which meet the requirements for high speeds, integration of fast I/O cards, and a flexible, modular and rugged design. • An integrated programming environment with SIMATIC STEP 7. • Automation products from Siemens comply with the stringent requirements of the offshore sector. The advantages of the solution with SIMATIC PC-based Automation: • Enhanced efficiency by optimizing the complete production organization through a high degree of uniformity. • Minimized use of resources (less paper is required in production). • Simple, low-cost retrofitting of the Panel PC directly in production on a stand, without the installation of an additional operator console. Siemens ST 80 / ST PC · 2013 1/11 1 © Siemens AG 2013 Introduction ■ Overview (continued) PC-based control in automotive test rigs PC-based control in the semiconductor industry Test rigs in the automotive industry require trouble-free operation and high quality. A high-performance system is required in the control, processing, archiving and visualization of measured data which can also provide openness and flexibility for connection to different bus systems and for the use of software. The advantages of the solution with SIMATIC PC-based Automation: • Flexible, easy-to-service and maintenance-friendly system with Windows XP Embedded in conjunction with SIMATIC WinAC. • Reduction in integration overhead thanks to integral interfaces such as PROFINET, PROFIBUS, Ethernet, CAN, and the flexibility when using modules for different bus systems, e.g. PC/104. • System availability concept ensures round-the-clock operation and reduced downtime costs. • Fan-free, temperature-resistant operation up to 50°C saves additional cooling measures. • High investment security through long-term availability of the components. Touch panel In the semiconductor industry, high quality and fault-free operation round-the-clock are decisive criteria. A high-performance system that guarantees fast and precise production of the semiconductors is required for controlling the machines, monitoring the production system, and processing the production data. High flexibility and openness are also required for connecting to the production control system and machine engineering system. The advantages of the solution with SIMATIC PC-based Automation: • Compact, rugged industrial PCs with powerful processors and the latest technology enable high processing performance. • Pre-installed systems save time and costs when integrated into the overall system. • WinCC ToolLink-EDA (equipment data acquisition) enables diagnostics of process and machine data in real time. • System availability concept with integral RAID1 functionality and remote monitoring with SIMATIC PC DiagMonitor ensures fault-free 24-hour operation. • High investment security through long-term availability of the components. • International certification and worldwide support guarantee global use. Touch Panel Host Industrial Ethernet Microbox PC IPC427 Label printer Industrial Ethernet CAN-Bus Barcode reader SIMATIC IPC627 Vehicle control unit Machine control Visualization PROFIBUS DP Distributed I/O devices Distributed I/O devices Sensors Sensors The plant concept 1/12 Siemens ST 80 / ST PC · 2013 SIMATIC IPC627 Industrial Ethernet Port to engineering system HUB HMI Panel The plant concept Measuring and control instruments Sensors G_ST80_XX_00434 RS232 USB G_ST80_XX_00433 1 SIMATIC PC-based Automation © Siemens AG 2013 Introduction SIMATIC PC-based Automation ■ Overview (continued) Track & trace line controller for tobacco industry In order to comply with new legal regulations, a track & trace system in an existing plant has been extended. The requirement is to test 100 cartons per minute in three-shift operation and to save the data in an SQL database for traceability reasons. The automation system should be characterized by high ruggedness, but also offer the openness required to connect additional components such as printers and the Machine Vision system. The advantages of the solution with SIMATIC PC-based Automation: • Compact automation solution consisting of embedded industrial PC Microbox PC IPC427, PLC with preinstalled and ready-to-use software PLC WinAC RTX, and visualization with WinCC flexible. • Control of the entire track & trace system and interfacing to the control system. • Open solution with the help of the WinAC ODK (Open Development Kit) thanks to a link to an SQL database for managing the serial numbers and other data. • Additional openness and flexibility by connecting printers and vision system. Retrofit of a woodworking machine – safe! In the past, machines and plants for wood-working were equipped with specially developed, proprietary controllers. Today, futureoriented standard components are used for retrofit projects. The customer decided in favor of integrating standard automation and safety technology in a single unit with the SIMATIC WinAC RTX F software controller in a fan-free and maintenancefree IPC, the SIMATIC IPC427C Microbox PC. PROFINET as an innovative fieldbus connects distributed I/O, safety and operator panels quickly and easily. The advantages of the solution with SIMATIC PC-based Automation: • The compact PC-based automation solution multiplies the performance and precision of the plant. • Implementation of PROFINET resulted in a series of additional advantages such as the diagnostics capability. • Integration of standard and fail-safe automation in a single unit achieved component savings. The size of the cabinet was reduced by 20 percent and the wiring by 50 percent. The customer benefited from a high level of operating convenience and minimized machine downtimes. www.siemens.com/reference-video-kuper Siemens ST 80 / ST PC · 2013 1/13 1 © Siemens AG 2013 Introduction ■ Overview (continued) Image processing with data backup In image processing applications, high performance computers are required due to the large volume of data to be processed. The image data must be recorded, processed and saved quickly. Frame grabber cards with a high data throughput, for example, are used for recording image data. The interfaces for the expansion cards must not become bottle-necks in this case. To ensure continued problem-free processing of the acquired data, you need a state-of-the-art system with up-to-date processor and memory technology. Lots of data is produced again during the subsequent data backup. Thus the available storage medium must be fast and fail-safe at the same time. An open system is required for connecting to existing plants. The advantages of the solution with SIMATIC PC-based Automation: • Rugged SIMATIC PC with state-of-the-art processor performance and the latest technology. • Current interfaces such as PCI Express for applications with a high data throughput rate, e.g. frame grabber cards for recording image data. • Visualization on up to two monitors with an optional, high-performance graphics card. • Onboard communication interfaces such as Ethernet and PROFINET, e.g. for connecting to EPS systems or integration in existing systems. • International certifications and global support facilitate the worldwide use of the image processing solution. Control room Server room Rack PC IPC547 for visualization and intermediate storage of data Flat Panel Rack PC IPC547 – Server for data management Industrial Ethernet Machine-level Rack PC IPC847 with PCIe frame grabber cards Camera . . . The plant concept 1/14 Siemens ST 80 / ST PC · 2013 High-performance industrial PC for reliable control and monitoring of wind power plants. All Siemens turbines for offshore wind power plants feature special technical characteristics that ensure long-term, low-maintenance operation. In contrast to sites on land, offshore wind farms are not always accessible to service teams. The basic quality requirements and standards for all components used in terms of absolute fail-safety and reliability, are therefore extremely high. The SIMATIC Box PC of the 627 series that has been implemented matches the requirements of the solution provider all the way down the line. The rugged industrial PC is designed for 24-hour continuous duty at ambient temperatures up to 55 °C. For reliable operation, the Box PC is installed in a solid metal enclosure that is resistant to shock and vibration and that demonstrates a high degree of of electromagnetic compatibility (EMC). For a high level of data security, the option of a mirror disk system with two hard disks (RAID1) was selected. The RAID1 controller is already onboard, and does not occupy a PCI slot. The rugged, reliable hardware with extremely compact dimensions in durable industrial design also stands up to the demands of continuous operation in a harsh environment. The advantages of the solution with SIMATIC PC-based Automation: • The mounting dimensions of Box PCs remain identical over several device generations and mounting solutions can be simply reused for the next generation. • Furthermore, when a new device generation is used, any frontaccessible interfaces and function elements can be retained. For example, the Siemens Wind division already utilized a complete lifecycle of a Box PC generation and no adjustments to a new hardware platform were required when the successor product was introduced. • Through compliance with international standards, such as CE and UL, and worldwide service, the Box PC can be implemented round the globe. G_ST80_XX_00436 1 SIMATIC PC-based Automation 2 © Siemens AG 2013 Operator panels 2/2 Introduction 2/6 2/6 Key Panels SIMATIC HMI KP8/KP8F/32F 2/12 2/12 Basic Panels Basic Panels – Standard 2/24 SIPLUS Basic Panels 2/26 2/26 Comfort Panels Comfort Panels – Standard 2/40 SIPLUS Comfort Panels 2/44 2/45 2/52 2/57 2/69 2/70 2/73 2/74 2/74 2/75 Mobile Panels SIMATIC Mobile Panel 177 SIMATIC Mobile Panel 277 SIMATIC Mobile Panel 277(F) IWLAN System components for Mobile Panels Terminal boxes SIPLUS connection boxes System components Charging station Transponder 2/76 2/77 2/79 System interfaces with WinCC (TIA Portal) SIMATIC S7 Controllers from other manufacturers 2/83 2/84 2/87 2/89 2/90 System interfaces with WinCC flexible SIMATIC S7 SIMATIC S5 SIMATIC 505 PLCs from other manufacturers 2/96 2/96 2/97 2/98 2/99 2/100 2/101 2/104 2/104 2/105 2/109 2/110 2/112 2/116 2/118 2/122 2/124 2/130 2/135 2/137 SIMATIC HMI accessories General HMI accessories Industrial USB Hub 4 Touch pen and touch stylus SIMATIC Mobile Panel accessories Power supply unit Additional accessories SIMATIC HMI accessories Connectors/converters/adapters HMI connecting components RS485 bus connector IE FC RJ45 Plug 2 x 2 Connecting cables Memory media Service sets Protective covers Protective films Fasteners Labeling strips Batteries Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels Introduction Introduction ■ Overview Highest demands in terms of performance and functionality? Brilliant widescreen displays from 4"... 22" Innovative commissioning and service concept Energy management with PROFIenergy 2 Comfort Panels Basic Panels Low priced, pixel graphics operator prompting? Mobile Panels Key Panels Intuitive operation of 3"... 15" Integrated HMI basis functionality Perfect interaction with SIMATIC S7-1200 Maximum mobility and flexibility? Innovative operation with and without cable Robust for site-related local operation Integrated safety concept Eng inee Fast commissioning Easy networking Intuitive state detection red w ith Tota lly tion Integrated Automa al Port G_ST80_XX_00501 Flexible expansion with keys – or even safety functions? A finely graded range of HMI devices is available for local operator control and monitoring: From Key Panels and Basic Panels to Comfort Panels and Mobile Panels. HMI devices with all-round IP65/NEMA 4 protection for distributed configurations are available for applications with especially high requirements with regard to ruggedness. Comfort Panels Key Panels The Comfort Panels are equipped with PROFINET/Ethernet as well as PROFIBUS DP/MPI interfaces. Key Panels (KP) are the innovative alternative to conventionally wired operator keypads. Supplied pre-assembled and ready for installation, the bus-compatible operator panels are the key to drastically reducing wiring times when compared with conventional methods. Basic Panels Basic Panels offer basic HMI functionality for small machines and applications. They are available in 3" and 4" sizes as a pure Key Panel (KP), from 4" to 10" with touch screen and additional keys (KTP), and as a pure Touch Panel (TP) in size 15". Variants can be selected for connection to PROFINET/Ethernet or PROFIBUS DP/MPI. 2/2 Siemens ST 80 / ST PC · 2013 Comfort Panels offer high-end functionality for demanding applications. They offer high-resolution widescreen displays in sizes from 4" to 22", alternatively for touch screen operation (TP) or key operation (KP). In size 4" also with touch screen and additional keys (KTP). Mobile Panels The portable operator panels facilitate operator control and monitoring at the actual scene of the event with direct access and visual contact to the process. They provide simple and safe reconnection during operation (Mobile Panel 177 and Mobile Panel 277) or wireless freedom (Mobile Panel 277 (F) IWLAN) and can therefore be used flexibly on a machine or system. © Siemens AG 2013 Operator panels Introduction Introduction ■ Overview (continued) Rugged and compact for use at machine level Open for a wide variety of automation systems With IP65/NEMA 4 degree of protection at the front, high EMC and extreme vibration resistance, the SIMATIC HMI operator panels are ideally suited for use at machine level in rough industrial environments. Thanks to their compact design with a shallow mounting depth, the stationary HMI devices can be fitted anywhere, even where only restricted space is available. For distributed configurations, there are also devices available with all-round IP65/NEMA 4 protection. Despite being consistently incorporated into the SIMATIC world, the Panels are nevertheless open for connection to PLCs from many different vendors. The standard delivery includes a comprehensive range of user-friendly drivers. The extremely rugged and shock-proof enclosure with degree of protection IP65 makes the Mobile Panels especially suitable for industrial applications. Their low weight and ergonomic design means that they are user-friendly and easy to operate. One configuration software for everything SIMATIC WinCC (TIA Portal) is a tool for the uniform configuration of all SIMATIC HMI Panels as well as PC-based systems. Graded variants are available for every task. The software permits simple and efficient configuration. Programming experience is not required. Once created, configurations can be reused within the family. Component of Totally Integrated Automation Siemens provides the complete modular system of matched components for automation solutions from one source and — with Totally Integrated Automation — one of the most globally successful automation concepts. SIMATIC WinCC (TIA Portal) is an integral component of this world. It offers crucial advantages. Thanks to the triple uniformity in configuration/programming, data management and communication, automation solution engineering costs are significantly reduced. Innovative operator control and monitoring The SIMATIC HMI Panels facilitate innovative operator control and monitoring combined with ruggedness, stability and simplicity. On the Comfort Panels in particular, standard hardware and software interfaces, e.g. the Multimedia Card/ SD Card, USB, Ethernet, PROFIBUS DP and Visual Basic scripts, provide more flexibility and openness as well as access to the office world. Worldwide application The SIMATIC HMI Panels are ideally equipped for global use. Online language switching permits selection of up to 32 languages during operation simply by pressing a button. The wide variety available also includes, for example, Asian logographic languages (Chinese, Taiwanese, Korean, Japanese) or Russian. The configuration interface of WinCC (TIA Portal) including the online help and the complete documentation is also multilingual. Up to 32 languages can be used in one project. And all this is complemented by global service and support from Siemens. Siemens ST 80 / ST PC · 2013 2/3 2 © Siemens AG 2013 Operator panels Introduction Introduction ■ Overview (continued) Configuration at a Glance WinCC (TIA Portal) engineering software Basic Comfort Advanced Professional Basic Panels 2 KP300 Basic • • • • KTP400 Basic mono PN • • • • KTP400/KP400 Basic color PN • 2) • 2) • 2) • 2) KTP600 Basic • • • • KTP1000 Basic • • • • TP1500 Basic • • • • Comfort Panels KTP400/KP400 Comfort • • • TP700/KP700 Comfort • • • TP900/KP900 Comfort • • • TP1200/KP1200 Comfort • • • TP1500/KP1500 Comfort • 2) • 2) • 2) TP1900 Comfort • 2) • 2) • 2) TP2200 Comfort 2) 2) • 2) • • Mobile Panels Mobile Panel 177 • • • Mobile Panel 277 • • • Mobile Panel 277(F) IWLAN • 3) • 3) • 3) Panels – 70 series OP73 • • • OP77A • • • OP77B • • • TP 177A • • • TP/OP 177B • • • • • • • • • • • • • • • WinAC MP 177 • 1) • 1) • 1) WinAC MP 277 • 1) • 1) • 1) WinAC MP 377 • 1) • 1) • 1) Panels – 170 series Panels – 270 series TP 277/OP 277 Multi Panels – 170 series MP 177 Multi Panels – 270 series MP 277 Multi Panels – 370 series MP 377 WinAC MP • Possible 1) from WinCC (TIA Portal) V11 SP1 2) from WinCC (TIA Portal) V11 SP2 Update 2 from WinCC (TIA Portal) V11 SP2 3) 2/4 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels Introduction Introduction ■ Overview (continued) WinCC flexible engineering software Micro Compact Standard Advanced •5) •5) •5) 5) 5) Basic Panels KTP400 Basic mono PN KTP600 Basic • • •5) KTP1000 Basic •4) •4) •4) TP1500 Basic •4) •4) •4) • 1) • 1) • 1) 2 Mobile Panels Mobile Panel 177 Mobile Panel 277 Mobile Panel 277(F) IWLAN • 2) 4) • 2) 4) • 3) • 3) Micro Panels OP 73micro • • • • TP 177micro • • • • OP 73 • • • OP 77A/B • • • TP 177A • • • TP/OP 177B • 1) • 1) • 1) • 2) • 2) • 4) • 4) • • • 3) • 3) • 5) • 5) • 5) • 5) • 5) • 5) Panels – 70 series Panels – 170 series Panels – 270 series TP 277/OP 277 Multi Panels – 170 series MP 177 • 5) Multi Panels – 270 series MP 277 Multi Panels – 370 series MP 377 WinAC MP WinAC MP 177 • 5) WinAC MP 277 WinAC MP 377 • Possible 1) WinCC flexible 2005 or higher and TP 177B 4" with WinCC flexible 2008 and higher 2) WinCC flexible 2005 SP1 and higher WinCC flexible 2007 and higher: Mobile Panel 277(F) IWLAN V1; WinCC flexible 2008 SP2 and higher: Mobile Panel 277(F) IWLAN V2 3) 4) 5) WinCC flexible 2008 and higher WinCC flexible 2008 SP1 and higher Siemens ST 80 / ST PC · 2013 2/5 © Siemens AG 2013 Operator panels Key Panels SIMATIC HMI KP8/KP8F/32F ■ Overview 2 SIMATIC HMI KP32F and HMI KP8 Empty front (similar to figure) Empty front (similar to figure) 2/6 Siemens ST 80 / ST PC · 2013 SIMATIC HMI Key Panels • Optimum operability thanks to large mechanical keys and multi-colored LED backlighting (daylight readable) • Over 60% time savings for wiring and installation (Plug&Play) • More than 30% savings in material costs compared to conventional keypad operator panels • 2 PROFINET ports (incl. switch) already integrated for setting up line and ring topologies • Freely configurable digital I/Os on the rear for connecting key-operated switches, indicator lamps, etc. • Connection of fail-safe emergency stop buttons or other fail-safe signals with KP8F and KP32F (in SIL2 or SIL3) • Functionally compatible with all standard PROFINET master CPUs, also non-Siemens • KP8 and empty front design, also optimized for installation in IPC Extension Units in IP65 • Maximum flexibility due to parameterization • Empty front design for standardized assembly of flexible operator panels • KP8 and empty front design, also optimized for installation in IPC Extension Units in IP65 © Siemens AG 2013 Operator panels Key Panels SIMATIC HMI KP8/KP8F/32F ■ Technical specifications 6AV3688-3AY36-0AX0 6AV3688-3AF37-0AX0 6AV3688-3EH47-0AX0 6AV3688-3XY38-3AX0 SIMATIC HMI KP8 PN SIMATIC HMI KP8F PN SIMATIC HMI KP32F PN SIMATIC HMI design empty front Yes Yes Yes No Yes; Automatically when switching on Yes; Automatically when switching on Yes; Automatically when switching on No Yes Yes Yes No 8 8 32 0 8 5; Red, green, blue, white, yellow 8 32 5; Red, green, blue, white, yellow 32 0 0 • Number/keys 8 5; Red, green, blue, white, yellow 8 Installation type/mounting Rack mounting possible Control elements With parameterizable keys With key and signal lamp test Keyboard fonts • freely inscribable membrane keys • Short stroke keys - Number of short-stroke keys Expansions for operator control of the process • Number/LEDs • Number of color modes for LED 2 0 No No No No Design/front/fastening Yes; Compatible with extension unit dimensions Yes; Compatible with extension unit dimensions Yes Yes; Compatible with extension unit dimensions Mounting rail installation possible No No No No Wall mounting/direct mounting possible No No No No Mounting in portrait format possible Yes Yes Yes Yes Mounting in landscape format possible Yes Yes Yes Yes Yes Yes Yes Yes 0 0 0 5; Max. 5 possible Supply voltage Type of supply voltage DC DC DC external Rated voltage/DC 24 V 24 V 24 V permissible range, lower limit (DC) 20.4 V 20.4 V 20.4 V permissible range, upper limit (DC) 28.8 V 28.8 V 28.8 V Type of output LED colors • Red • Yellow • Green • white • blue Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No No No No No 8; Max. 8 inputs and outputs (total) 8; Max. 32 inputs and outputs (total) 32; Max. 32 inputs and outputs (total) 0 8; Max. 8 inputs and outputs (total) 8; Max. 8 inputs and outputs (total) 16; Max. 32 inputs and outputs (total) 0 Mounting technology • Clamp terminals Number of slots for command devices and signaling units Digital inputs Number/binary inputs Digital outputs Number/binary outputs Load "resistive" 100 mA 100 mA 100 mA Voltage (DC) 24 V; Non-isolated 24 V; Non-isolated 24 V; Non-isolated Number of digital outputs • Output current (per output) max. • Total current (per group), max. • Short-circuit protection 100 mA 800 mA Yes 100 mA 800 mA Yes 100 mA 800 mA Yes No Siemens ST 80 / ST PC · 2013 2/7 © Siemens AG 2013 Operator panels Key Panels SIMATIC HMI KP8/KP8F/32F ■ Technical specifications (continued) 2 6AV3688-3AY36-0AX0 6AV3688-3AF37-0AX0 6AV3688-3EH47-0AX0 6AV3688-3XY38-3AX0 SIMATIC HMI KP8 PN SIMATIC HMI KP8F PN SIMATIC HMI KP32F PN SIMATIC HMI design empty front 2; Incl. switch 2; Incl. switch 2; Incl. switch 0 2; For the construction of lines and rings without external switch 2; Per port 2; Per port 2; For the construction of lines and rings without external switch 2; Per port 2; Per port 2; For the construction of lines and rings without external switch 2; Per port 2; Per port 0 Protocols PROFINET Yes; Incl. shared device Yes; Incl. shared device Yes; Incl. shared device No Supports protocol for PROFINET IO Yes Yes Yes No IRT supported Yes Yes Yes No MRP supported Yes Yes Yes No PROFINET CBA No No No No Supports protocol for PROFIsafe No Yes; Mode V2.0; 2 inputs can be used Yes; Mode V2.0; 4 inputs can be used No PROFIBUS No No No No Test commissioning functions Illuminant test Yes; During switch on Yes; During switch on Yes; During switch on No Pushbutton and lamp test Yes; During switch on Yes; During switch on Yes; During switch on No Yes; Group 1, measured at a distance of 10 m No Yes; Group 1, measured at a distance of 10 m No Yes; Group 1, measured at a distance of 10 m No No Degree and class of protection Type of protection IP20 IP20 IP20 IP20 IP (at the front) IP65 IP65 IP65 IP65 Enclosure type 4x at the front Yes; Incl. NEMA12 Yes; Incl. NEMA12 Yes; Incl. NEMA12 No Standards, approvals, certificates CE Yes Yes Yes Yes KC approval Yes Yes Yes No cULus Yes Yes Yes No C-TICK Yes Yes Yes No GL No No No No ABS No No No No BV No No No No DNV No No No No LRS No No No No Class NK No No No No PRS No No No No Suitable for safety functions No Yes Yes Yes; e.g. installation of emergency stop Yes Yes No Yes Yes Yes No Yes No; On request No; On request No Yes No No No No Yes Yes; Available soon Yes No Interfaces Supports protocol for PROFINET IO • Number of PROFINET interfaces Industrial Ethernet • Number of industrial Ethernet interfaces • Industrial Ethernet status LED • Number of ports of the integrated switch EMC Emission of radio interference acc. to EN 55 011 • Emission of radio interferences acc. to EN 55 011 (limit class A) • Emission of radio interference acc. to EN 55 011 (limit class B) Use in hazardous areas • ATEX Zone 2 • ATEX Zone 22 • cULus Class I Zone 1 • cULus Class I Zone 2, Division 2 • FM Class I Division 2 2/8 Siemens ST 80 / ST PC · 2013 0 0 No © Siemens AG 2013 Operator panels Key Panels SIMATIC HMI KP8/KP8F/32F ■ Technical specifications (continued) 6AV3688-3AY36-0AX0 6AV3688-3AF37-0AX0 6AV3688-3EH47-0AX0 6AV3688-3XY38-3AX0 SIMATIC HMI KP8 PN SIMATIC HMI KP8F PN SIMATIC HMI KP32F PN SIMATIC HMI design empty front vertical vertical vertical Any 30°; To the front/rear 30°; To the front/rear 30°; To the front/rear 180°; To the front/rear 55 °C 0 °C 55 °C 0 °C 55 °C 0 °C 55 °C 0 °C 0 °C 0 °C 0 °C 0 °C 55 °C 55 °C 55 °C 55 °C 0 °C 0 °C 0 °C 0 °C 45 °C 45 °C 45 °C 45 °C 0 °C 0 °C 0 °C 0 °C 45 °C 45 °C 45 °C 45 °C 0 °C 0 °C 0 °C 0 °C 45 °C 45 °C 45 °C 45 °C Storage/transport temperature • Min. • max. -20 °C 60 °C -20 °C 60 °C -20 °C 60 °C -20 °C 60 °C Relative humidity • max. relative humidity 95 % 95 % 95 % 95 % Yes Yes Yes Yes Yes Yes No No Yes Yes No Yes No Yes No No No No No No No No No No Yes Yes No Yes No Yes No No No No No No No No No No Yes Yes No Yes No Yes No No No No No No No No No No Yes Yes No Yes No Yes No No No No No No No No No No Ambient conditions Mounting position maximum permissible angle of inclination without external ventilation Operating temperature • Operating temperature range, max. • Operating temperature range, min. • Operation (vertical installation) - in vertical mounting position/ minimum - in vertical mounting position/ maximum • Operation (max. tilt angle) - at maximum tilt angle/ minimum - at maximum tilt angle/ maximum • Operation (vertical installation, portrait format) - in vertical mounting position/ minimum - in vertical mounting position/ maximum • Operation (max. tilt angle, portrait format) - at maximum tilt angle/ minimum - at maximum tilt angle/ maximum Configuration Configuration software • STEP 7 Basic (TIA Portal) • STEP 7 Professional (TIA Portal) Functionality under WinCC (TIA Portal) Process coupling • S7-1200 • S7-1500 • S7-200 • S7-300/400 • LOGO! • Win AC • SINUMERIK • SIMOTION • Allen Bradley (EtherNet/IP) • Allen Bradley (DF1) • Mitsubishi (MC TCP/IP) • Mitsubishi (FX) • OMRON (FINS TCP) • OMRON (LINK/Multilink) • Modicon (Modbus TCP/IP) • Modicon (Modbus) Siemens ST 80 / ST PC · 2013 2/9 2 © Siemens AG 2013 Operator panels Key Panels SIMATIC HMI KP8/KP8F/32F ■ Technical specifications (continued) 2 6AV3688-3AY36-0AX0 6AV3688-3AF37-0AX0 6AV3688-3EH47-0AX0 6AV3688-3XY38-3AX0 SIMATIC HMI KP8 PN SIMATIC HMI KP8F PN SIMATIC HMI KP32F PN SIMATIC HMI design empty front Yes No Yes No No Yes No Yes 1500000 1500000 1500000 Dimensions Width of the housing front 98 mm 98 mm 295 mm 98 mm Height of housing front 155 mm 155 mm 155 mm 155 mm 68 mm; Max. thickness of mounting plate 2-6 mm 129 mm 68 mm; Max. thickness of mounting plate 2-6 mm 129 mm 277 mm; Max. thickness of mounting plate 2-6 mm 137 mm 68 mm; Max. thickness of mounting plate 2-6 mm 129 mm 49 mm; Incl. angled SIMATIC Ethernet connector 49 mm; Incl. angled SIMATIC Ethernet connector 69 mm; Incl. angled SIMATIC Ethernet connector 49 mm 270 g 280 g 1 220 g 240 g Mechanics/material Type of housing (front) • Plastic • Aluminum Lifetime, typ. • Short-stroke keys (in switching cycles) Mounting cutout (W x H x D) • Mounting cutout, width • Mounting cutout, height Depth/installation dimension Weight Weight without packaging ■ Ordering data SIMATIC HMI KP8 PN Order No. 6AV3688-3AY36-0AX0 Key Panel, 8 short-stroke keys with multicolored LEDs, PROFINET interfaces, 2 x parameterizable with STEP 7 V5.5 or higher SIMATIC HMI KP8F PN 6AV3688-3AF37-0AX0 Key Panel, 8 short-stroke keys with multicolored LEDs, PROFINET interfaces with PROFIsafe, parameterizable with STEP 7 V5.5 or higher; 4 additional fail-safe inputs. Can be used as 2 x SIL 2 or 1 x SIL 3 SIMATIC HMI KP32F PN 6AV3688-3EH47-0AX0 Key Panel, 32 short-stroke keys with multicolored LEDs, PROFINET interfaces with PROFIsafe, parameterizable with STEP 7 V5.5 or higher; including 8 fail-safe inputs. Can be used as 4 x SIL 2 or 2 x SIL 3 Empty front design 6AV3688-3XY38-3AX0 for standard 22.5 mm operator controls, same mounting dimensions as KP8 Demo case A5E31477788 SIMATIC HMI Key Panel – low-cost demo and experiment case • Includes: - 1x case - 1x KP8 PN - 1x CPU1211C - 1x stand, permanently wired, including program • Power supply possible with a standard laptop mains adapter (not included in scope of supply) Only by fax to Siemens AG, Mr. Michael Christ Industry Sector, I IA CE SE MF RS FDS Wuerzburger Str. 121, 90766 Fuerth, Germany Tel.: +49 911 750-4128 Fax: +49 911 750-2411 2/10 Siemens ST 80 / ST PC · 2013 Order No. Documentation You can find the manual for the Key Panels on the Internet at: http://support.automation.siemens.com/WW/view/en/56652789 Accessories See SIMATIC HMI accessories, from page 2/96 © Siemens AG 2013 Operator panels Key Panels SIMATIC HMI KP8/KP8F/32F ■ Dimensional drawings ■ More information All dimensions in mm. For installation cutout, see technical specifications. Additional information is available on the Internet at: http://www.siemens.com/simatic-key-panels 13.7 Note: Do you need a specific modification or extension to the products described here? If so, refer to "Customized Automation". There you will find information about additional and generally available sector-specific products as well as options for customer-specific modification and adaptation. 127.7 155 Demo case Can be ordered by fax: Siemens AG, Mr. Michael Christ Industry Sector, I IA CE SE MF RS FDS Wuerzburger Str. 121, 90766 Fuerth, Germany Phone: +49 911 750-4128 Fax: +49 911 750-2411 38 98 6 48.8 16.2 G_ST80_XX_00442 67.5 275 10 10 2 37 6 G_ST80_XX_00499 295 135 155 SIMATIC HMI Key Panel KP8; installation dimensions also valid for empty front design SIMATIC HMI Key Panel KP32F Siemens ST 80 / ST PC · 2013 2/11 2 © Siemens AG 2013 Operator panels Basic Panels Basic Panels – Standard ■ Overview • Ideal entry-level series from 3" to 15" for operating and monitoring compact machines and systems • Clear process representation thanks to use of pixel-graphics displays • Intuitive operation using Touch and tactile function keys • Equipped with all the necessary basic functions such as alarm logging, recipe management, plots, vector graphics, and language switching • Simple connection to the controller via integral Ethernet interface or separate version with RS 485/422 • Faster commissioning thanks to integrated diagnostics viewer and IP setting for SIMATIC S7-1200 and S7-1500 PLCs 2 ■ Technical specifications 6AV6647-0AA11-3AX0 6AV6647-0AK11-3AX0 6AV6647-0AB11-3AX0 6AV6647-0AC11-3AX0 SIMATIC HMI KTP400 Basic mono PN SIMATIC HMI KTP400 Basic color PN SIMATIC HMI KTP600 Basic mono PN SIMATIC HMI KTP600 Basic color DP Display Design of display STN TFT STN TFT Screen diagonal 3.8 in 4.3 in 5.7 in 5.7 in Number of colors 4; Grayscales 256 4; Grayscales 256 Resolution (pixels) • Horizontal image resolution • Vertical image resolution 320 240 480 272 320 240 320 240 Backlighting • MTBF backlighting (at 25 °C) • Dimmable backlight 30 000 h No 50 000 h No 50 000 h No 50 000 h No Control elements Keyboard fonts • Number of function keys 4 4 6 6 Touch operation • Design as touch screen Yes Yes Yes Yes Yes Yes Yes Yes Supply voltage Type of supply voltage DC DC DC DC Rated voltage/DC 24 V 24 V 24 V 24 V Memory Usable memory for user data 1 Mbyte 1 Mbyte 1 Mbyte 1 Mbyte Type of output Acoustics • Buzzer Yes Yes Yes Yes Time of day Clock • Software clock • Battery-backed • Synchronizable Yes No Yes Yes No Yes Yes No Yes Yes No Yes Interfaces Number of RS 485 interfaces 0 0 0 1 Number of USB interfaces 0 0 0 0 Number of SD card slots 0 0 0 0 Industrial Ethernet • Number of industrial Ethernet interfaces 1 1 1 0 Installation type/mounting Mounting in portrait format possible 2/12 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels Basic Panels Basic Panels – Standard ■ Technical specifications (continued) 6AV6647-0AA11-3AX0 6AV6647-0AK11-3AX0 6AV6647-0AB11-3AX0 6AV6647-0AC11-3AX0 SIMATIC HMI KTP400 Basic mono PN SIMATIC HMI KTP400 Basic color PN SIMATIC HMI KTP600 Basic mono PN SIMATIC HMI KTP600 Basic color DP Protocols PROFINET Yes Yes Yes No PROFIBUS No No No Yes MPI No No No Yes Degree and class of protection Type of protection IP20 IP20 IP20 IP20 IP (at the front) IP65 IP65 IP65 IP65 Enclosure type 4x at the front Yes Yes Yes Yes Standards, approvals, certificates CE Yes Yes Yes Yes cULus Yes Yes Yes Yes GL Yes Yes Yes Yes ABS Yes Yes Yes Yes BV Yes Yes Yes Yes DNV Yes Yes Yes Yes LRS Yes Yes Yes Yes Class NK Yes Yes Yes Yes No No No No No No No No No No No No No No No No 0 °C 0 °C 0 °C 0 °C 50 °C 50 °C 50 °C 50 °C 90 % 90 % 90 % 90 % Yes; via integrated WinCC Basic (TIA Portal) Yes Yes Yes; via integrated WinCC Basic (TIA Portal) No Yes Yes; via integrated WinCC Basic (TIA Portal) Yes Yes Yes; via integrated WinCC Basic (TIA Portal) Yes Yes 5 5 5 5 No Yes No Yes No Yes No Yes 200 15 200 15 200 15 200 15 256 Yes Yes 256 Yes Yes 256 Yes Yes 256 Yes Yes 5 40 kbyte No 5 40 kbyte No 5 40 kbyte No Use in hazardous areas • ATEX Zone 2 • ATEX Zone 22 • cULus Class I Zone 2, Division 2 • FM Class I Division 2 Ambient conditions Operating temperature • Operation (vertical installation) - in vertical mounting position/ minimum - in vertical mounting position/ maximum Relative humidity • max. relative humidity Configuration Configuration software • STEP 7 Basic (TIA Portal) • WinCC flexible Compact • WinCC Basic (TIA Portal) Languages Online languages • Number of online/runtime languages Functionality under WinCC (TIA Portal) Task planner • time-controlled • task-controlled With alarm logging system (incl. buffer and acknowledgment) • Number of bit messages • Number of analog messages • Message buffer - Number of entries - Circulating buffer - retentive Recipes • Number of recipes 5 • Size of internal recipe memory 40 kbyte No • Recipe memory expandable Siemens ST 80 / ST PC · 2013 2 2/13 © Siemens AG 2013 Operator panels Basic Panels Basic Panels – Standard ■ Technical specifications (continued) 2 6AV6647-0AA11-3AX0 6AV6647-0AK11-3AX0 6AV6647-0AB11-3AX0 6AV6647-0AC11-3AX0 SIMATIC HMI KTP400 Basic mono PN SIMATIC HMI KTP400 Basic color PN SIMATIC HMI KTP600 Basic mono PN SIMATIC HMI KTP600 Basic color DP 250 500 500 500 30 30 30 30 Images • Number of configurable images 50 50 50 50 Archiving • Number of archives per device 0 0 0 0 Security • Number of user groups • Number of users 50 50 50 50 50 50 50 50 Transfer (upload/download) • MPI/PROFIBUS DP • Ethernet No Yes No Yes No Yes Yes No Process coupling • S7-1200 • S7-1500 • S7-200 • S7-300/400 • LOGO! • Win AC • SIMOTION • Allen Bradley (EtherNet/IP) • Allen Bradley (DF1) • Mitsubishi (MC TCP/IP) • Mitsubishi (FX) • OMRON (FINS TCP) • OMRON (LINK/Multilink) • Modicon (Modbus TCP/IP) • Modicon (Modbus) Yes Yes Yes Yes Yes Yes No Yes No Yes No No No Yes No Yes Yes Yes Yes Yes No No Yes No Yes No No No Yes No Yes Yes Yes Yes Yes Yes No Yes No Yes No No No Yes No Yes Yes Yes Yes Yes Yes No No Yes No Yes No Yes No Yes I/O I/O devices • Printer • Multi Media Card • SD card • USB memory No No No No No No No No No No No No No No No No Mechanics/material Type of housing (front) • Plastic Yes Yes Yes Yes Dimensions Width of the housing front 140 mm 140 mm 214 mm 214 mm Height of housing front 116 mm 116 mm 158 mm 158 mm Mounting cutout (W x H x D) • Mounting cutout, width • Mounting cutout, height 123 mm 99 mm 123 mm 99 mm 197 mm 141 mm 197 mm 141 mm Weight Weight without packaging 0.32 kg 0.34 kg 1.07 kg 1.07 kg Variables • Number of variables per device • Number of variables per screen 2/14 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels Basic Panels Basic Panels – Standard ■ Technical specifications (continued) 6AV6647-0AD11-3AX0 6AV6647-0AE11-3AX0 6AV6647-0AF11-3AX0 SIMATIC HMI KTP600 Basic color PN SIMATIC HMI KTP1000 Basic color DP SIMATIC HMI KTP1000 Basic color PN Display Design of display TFT TFT TFT Screen diagonal 5.7 in 10.4 in 10.4 in Number of colors 256 256 256 Resolution (pixels) • Horizontal image resolution • Vertical image resolution 320 240 640 480 640 480 Backlighting • MTBF backlighting (at 25 °C) • Dimmable backlight 50 000 h No 50 000 h No 50 000 h No Control elements Keyboard fonts • Number of function keys 6 8 8 Touch operation • Design as touch screen Yes Yes Yes Installation type/mounting Mounting in portrait format possible Yes No No Supply voltage Type of supply voltage DC DC DC Rated voltage/DC 24 V 24 V 24 V Memory Usable memory for user data 1 Mbyte 2 Mbyte 2 Mbyte Type of output Acoustics • Buzzer Yes Yes Yes Time of day Clock • Software clock • Battery-backed • Synchronizable Yes No Yes Yes No Yes Yes No Yes Interfaces Number of RS 485 interfaces 0 1 0 Number of USB interfaces 0 0 0 Number of SD card slots 0 0 0 Industrial Ethernet • Number of industrial Ethernet interfaces 1 0 1 Protocols PROFINET Yes No Yes PROFIBUS No Yes No MPI No Yes No Degree and class of protection Type of protection IP20 IP20 IP20 IP (at the front) IP65 IP65 IP65 Enclosure type 4x at the front Yes Yes Yes Standards, approvals, certificates CE Yes Yes Yes cULus Yes Yes Yes GL Yes Yes Yes ABS Yes Yes Yes BV Yes Yes Yes DNV Yes Yes Yes LRS Yes Yes Yes Class NK Yes Yes Yes Siemens ST 80 / ST PC · 2013 2 2/15 © Siemens AG 2013 Operator panels Basic Panels Basic Panels – Standard ■ Technical specifications (continued) 2 6AV6647-0AD11-3AX0 6AV6647-0AE11-3AX0 6AV6647-0AF11-3AX0 SIMATIC HMI KTP600 Basic color PN SIMATIC HMI KTP1000 Basic color DP SIMATIC HMI KTP1000 Basic color PN No No No No No No No No No No No No 0 °C 0 °C 0 °C 50 °C 50 °C 50 °C 90 % 90 % 90 % • WinCC flexible Compact • WinCC Basic (TIA Portal) Yes; via integrated WinCC Basic (TIA Portal) Yes Yes Yes; via integrated WinCC Basic (TIA Portal) Yes Yes Yes; via integrated WinCC Basic (TIA Portal) Yes Yes Languages Online languages • Number of online/runtime languages 5 5 5 Functionality under WinCC (TIA Portal) Task planner • time-controlled • task-controlled No Yes No Yes No Yes 200 15 200 15 200 15 256 Yes Yes 256 Yes Yes 256 Yes Yes Recipes • Number of recipes • Size of internal recipe memory • Recipe memory expandable 5 40 kbyte No 5 40 kbyte No 5 40 kbyte No Variables • Number of variables per device • Number of variables per screen 500 30 500 30 500 30 Images • Number of configurable images 50 50 50 Archiving • Number of archives per device 0 0 0 Security • Number of user groups • Number of users 50 50 50 50 50 50 Transfer (upload/download) • MPI/PROFIBUS DP • Ethernet No Yes Yes No No Yes Use in hazardous areas • ATEX Zone 2 • ATEX Zone 22 • cULus Class I Zone 2, Division 2 • FM Class I Division 2 Ambient conditions Operating temperature • Operation (vertical installation) - in vertical mounting position/ minimum - in vertical mounting position/ maximum Relative humidity • max. relative humidity Configuration Configuration software • STEP 7 Basic (TIA Portal) With alarm logging system (incl. buffer and acknowledgment) • Number of bit messages • Number of analog messages • Message buffer - Number of entries - Circulating buffer - retentive 2/16 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels Basic Panels Basic Panels – Standard ■ Technical specifications (continued) 6AV6647-0AD11-3AX0 6AV6647-0AE11-3AX0 6AV6647-0AF11-3AX0 SIMATIC HMI KTP600 Basic color PN SIMATIC HMI KTP1000 Basic color DP SIMATIC HMI KTP1000 Basic color PN Process coupling • S7-1200 • S7-1500 • S7-200 • S7-300/400 • LOGO! • Win AC • SIMOTION • Allen Bradley (EtherNet/IP) • Allen Bradley (DF1) • Mitsubishi (MC TCP/IP) • Mitsubishi (FX) • OMRON (FINS TCP) • OMRON (LINK/Multilink) • Modicon (Modbus TCP/IP) • Modicon (Modbus) Yes Yes Yes Yes Yes Yes No Yes No Yes No No No Yes No Yes Yes Yes Yes Yes Yes No No Yes No Yes No Yes No Yes Yes Yes Yes Yes Yes Yes No Yes No Yes No No No Yes Yes I/O I/O devices • Printer • Multi Media Card • SD card • USB memory No No No No No No No No No No No No Mechanics/material Type of housing (front) • Plastic Yes Yes Yes Dimensions Width of the housing front 214 mm 335 mm 335 mm Height of housing front 158 mm 275 mm 275 mm Mounting cutout (W x H x D) • Mounting cutout, width • Mounting cutout, height 197 mm 141 mm 310 mm 248 mm 310 mm 248 mm Weight Weight without packaging 1.07 kg 2.65 kg 2.65 kg Siemens ST 80 / ST PC · 2013 2 2/17 © Siemens AG 2013 Operator panels Basic Panels Basic Panels – Standard ■ Technical specifications (continued) 2 6AV6647-0AH11-3AX0 6AV6647-0AJ11-3AX0 6AV6647-0AG11-3AX0 SIMATIC HMI KP300 Basic mono PN SIMATIC HMI KP400 Basic color PN SIMATIC HMI TP1500 Basic color PN Display Design of display FSTN TFT TFT Screen diagonal 3.6 in 4.3 in 15 in Number of colors 4; Backlit display only (white, red, green, yellow) 256 256 Resolution (pixels) • Horizontal image resolution • Vertical image resolution 240 80 480 272 1 024 768 Backlighting • MTBF backlighting (at 25 °C) • Dimmable backlight 50 000 h No 50 000 h No 50 000 h No Control elements Keyboard fonts • Number of function keys 10 8 0 Touch operation • Design as touch screen No No Yes Installation type/mounting Mounting in portrait format possible No No No Supply voltage Type of supply voltage DC DC DC Rated voltage/DC 24 V 24 V 24 V Memory Usable memory for user data 1 Mbyte 1 Mbyte 2 Mbyte Type of output Acoustics • Buzzer No No Yes Time of day Clock • Software clock • Battery-backed • Synchronizable Yes No Yes Yes No Yes Yes No Yes Interfaces Number of RS 485 interfaces 0 0 0 Number of USB interfaces 0 0 0 Number of SD card slots 0 0 0 Industrial Ethernet • Number of industrial Ethernet interfaces 1 1 1 Protocols PROFINET Yes Yes Yes PROFIBUS No No No MPI No No No Degree and class of protection Type of protection IP20 IP20 IP20 IP (at the front) IP65 IP65 IP65 Enclosure type 4x at the front Yes Yes Yes Standards, approvals, certificates CE Yes Yes Yes cULus Yes Yes Yes GL Yes No No ABS Yes No No BV Yes No No DNV Yes No No LRS Yes No No Class NK Yes No No 2/18 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels Basic Panels Basic Panels – Standard ■ Technical specifications (continued) 6AV6647-0AH11-3AX0 6AV6647-0AJ11-3AX0 6AV6647-0AG11-3AX0 SIMATIC HMI KP300 Basic mono PN SIMATIC HMI KP400 Basic color PN SIMATIC HMI TP1500 Basic color PN No No Yes No No No No No No No No No 0 °C 0 °C 0 °C 50 °C 50 °C 50 °C 90 % 90 % 90 % • WinCC flexible Compact • WinCC Basic (TIA Portal) Yes; via integrated WinCC Basic (TIA Portal) No Yes Yes; via integrated WinCC Basic (TIA Portal) No Yes Yes; via integrated WinCC Basic (TIA Portal) Yes Yes Languages Online languages • Number of online/runtime languages 5 5 5 Functionality under WinCC (TIA Portal) Task planner • time-controlled • task-controlled No Yes No Yes No Yes 200 15 200 15 200 15 256 Yes Yes 256 Yes Yes 256 Yes Yes Recipes • Number of recipes • Size of internal recipe memory • Recipe memory expandable 5 40 kbyte No 5 40 kbyte No 5 40 kbyte No Variables • Number of variables per device • Number of variables per screen 250 30 500 30 500 30 Images • Number of configurable images 50 50 50 Archiving • Number of archives per device 0 0 0 Security • Number of user groups • Number of users 50 50 50 50 50 50 Transfer (upload/download) • MPI/PROFIBUS DP • Ethernet No Yes No Yes No Yes Use in hazardous areas • ATEX Zone 2 • ATEX Zone 22 • cULus Class I Zone 2, Division 2 • FM Class I Division 2 Ambient conditions Operating temperature • Operation (vertical installation) - in vertical mounting position/ minimum - in vertical mounting position/ maximum Relative humidity • max. relative humidity Configuration Configuration software • STEP 7 Basic (TIA Portal) With alarm logging system (incl. buffer and acknowledgment) • Number of bit messages • Number of analog messages • Message buffer - Number of entries - Circulating buffer - retentive Siemens ST 80 / ST PC · 2013 2 2/19 © Siemens AG 2013 Operator panels Basic Panels Basic Panels – Standard ■ Technical specifications (continued) 2 6AV6647-0AH11-3AX0 6AV6647-0AJ11-3AX0 6AV6647-0AG11-3AX0 SIMATIC HMI KP300 Basic mono PN SIMATIC HMI KP400 Basic color PN SIMATIC HMI TP1500 Basic color PN Process coupling • S7-1200 • S7-1500 • S7-200 • S7-300/400 • LOGO! • Win AC • SIMOTION • Allen Bradley (EtherNet/IP) • Allen Bradley (DF1) • Mitsubishi (MC TCP/IP) • Mitsubishi (FX) • OMRON (FINS TCP) • OMRON (LINK/Multilink) • Modicon (Modbus TCP/IP) • Modicon (Modbus) Yes Yes Yes Yes Yes Yes No Yes No Yes No No No Yes No Yes Yes Yes Yes Yes No No Yes No Yes No No No Yes No Yes Yes Yes Yes Yes Yes No Yes No Yes No No No Yes Yes I/O I/O devices • Printer • Multi Media Card • SD card • USB memory No No No No No No No No No No No No Mechanics/material Type of housing (front) • Plastic Yes Yes Yes Dimensions Width of the housing front 165 mm 162 mm 400 mm Height of housing front 97 mm 189 mm 310 mm Mounting cutout (W x H x D) • Mounting cutout, width • Mounting cutout, height 149 mm 82 mm 135 mm 171 mm 367 mm 289 mm Weight Weight without packaging 0.25 kg 0.51 kg 4.2 kg 2/20 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels Basic Panels Basic Panels – Standard ■ Ordering data Order No. SIMATIC HMI Basic Panels, Key and Touch Order No. Starter kits 6AV6647-0AA11-3AX0 Starter kit SIMATIC S7-1200 + KP300 Basic mono PN 6AV6651-7HA01-3AA3 SIMATIC HMI KTP400 Basic mono PN 6AV6647-0AK11-3AX0 Starter kit SIMATIC S7-1200 + KTP400 Basic color PN 6AV6651-7KA01-3AA3 SIMATIC HMI KTP400 Basic color PN 6AV6647-0AB11-3AX0 Starter kit SIMATIC S7-1200 + KTP600 Basic color PN 6AV6651-7DA01-3AA3 SIMATIC HMI KTP600 Basic mono PN SIMATIC HMI KTP600 Basic color DP 6AV6647-0AC11-3AX0 SIMATIC HMI KTP600 Basic color PN 6AV6647-0AD11-3AX0 SIMATIC HMI KTP1000 Basic color DP 6AV6647-0AE11-3AX0 SIMATIC HMI KTP1000 Basic color PN 6AV6647-0AF11-3AX0 SIMATIC HMI Basic Panels, Key SIMATIC HMI KP300 Basic mono PN 6AV6647-0AH11-3AX0 SIMATIC HMI KP400 Basic color PN 6AV6647-0AJ11-3AX0 SIMATIC HMI Basic Panels, Touch SIMATIC HMI TP1500 Basic color PN 6AV6647-0AG11-3AX0 2 Starter kits with an S7-1200 consist of: • the respective SIMATIC HMI Basic Panel - SIMATIC HMI KP300 Basic mono PN - SIMATIC HMI KTP400 Basic color PN - SIMATIC HMI KTP600 Basic color PN • SIMATIC S7-1200 CPU 1212C AC/DC/Rly • SIMATIC S7-1200 Simulator Module SIM 1274 • SIMATIC STEP 7 BASIC CD • SIMATIC S7-1200 HMI Manual Collection CD • Ethernet CAT5 cable, 2 m LOGO! starter kit + KP300 Basic mono PN 6AV2132-0HA00-0AA0 LOGO! starter kit + KTP400 Basic color PN 6AV2132-0KA00-0AA0 Starter kits with a LOGO! consist of: • the respective SIMATIC HMI Basic Panel - SIMATIC HMI KP300 Basic mono PN - SIMATIC HMI KTP400 Basic color PN • LOGO! 12/24 RCE • LOGO! POWER 24 V 1.3 A • LOGO! SOFT COMFORT V7 • WINCC BASIC (TIA Portal) • Ethernet CAT5 cable, 2 m Documentation You can find the manual for the Basic Panels on the Internet at: http://support.automation.siemens.com Accessories See HMI accessories, from page 2/96 Siemens ST 80 / ST PC · 2013 2/21 © Siemens AG 2013 Operator panels Basic Panels Basic Panels – Standard ■ Dimensional drawings All dimensions in mm. For installation cutout, see technical specifications. 148 165 98 116 2 28.9 KTP400 Basic color PN 190 122 170 KP300 Basic 122 G_ST80_XX_00517 6.2 33.5 39.7 G_ST80_XX_00462 81 96.6 141 116 98 SIMATIC PANEL 162 33.5 KTP400 Basic mono PN 2/22 Siemens ST 80 / ST PC · 2013 40 6.2 G_ST80_XX_00355 140 KP400 Basic G_ST80_XX_00516 39.7 134 © Siemens AG 2013 Operator panels Basic Panels Basic Panels – Standard ■ Dimensional drawings (continued) 196 S 366 2 SIMATIC PANEL SIMATIC PANEL 310 288 140 158 S G_ST80_XX_00356 6.2 400 59.9 6.2 G_ST80_XX_00358 44 214 TP1500 Basic KTP600 Basic 309 S 60.2 6.2 335 G_ST80_XX_00357 247 275 SIMATIC PANEL KTP1000 Basic ■ More information Additional information is available in the Internet under: http://www.siemens.com/simatic-basic-panels Note Do you require a specific modification to or supplement for the products described here? Look under "Customized products". We provide information there about additional and generally available sector products, and about the customer-specific modification and adaptation options. Siemens ST 80 / ST PC · 2013 2/23 © Siemens AG 2013 Operator panels SIPLUS Basic Panels SIPLUS Basic Panels ■ Overview • Ideal entry-level series of 3.8 inches to 15 inches for operating and monitoring compact machines and systems • Clear process representation through the use of full-graphic displays • Intuitive operation via touch and tactile function keys • Equipped with all the necessary basic functions such as reporting, recipe management, curve representation, vector graphics, and language selection • Easy connection to the controller via integrated Ethernet interface or a separate version with RS485/422 2 Note: SIPLUS extreme products are based on Siemens Industry standard products. The contents listed here were taken from the respective standard products. SIPLUS extreme specific information was added. SIPLUS HMI KTP300 BASIC MONO PN SIPLUS HMI KTP400 BASIC MONO PN SIPLUS HMI KTP600 BASIC COLOR PN SIPLUS HMI KTP1000 BASIC COLOR DP SIPLUS HMI KTP1000 BASIC COLOR PN SIPLUS HMI TP1500 BASIC COLOR PN Order number 6AG16470AH11-2AX0 6AG16470AA11-2AX0 6AG16470AD11-2AX0 6AG1647-0AE11- 6AG1647-0AF114AX0 4AX0 6AG16470AG11-4AX0 Order No. based on 6AV6647-0AH113AX0 6AV6647-0AA113AX0 6AV6647-0AD113AX0 6AV6647-0AE113AX0 6AV6647-0AF113AX0 6AV6647-0AG113AX0 Ambient temperature range -25 ... +60 °C -10 ... +60 °C -25 ... +60 °C 0 ... +50 °C 0 ... +50 °C 0 ... +50 °C Conformal coating Coating of the printed circuit boards and the electronic components Technical data The technical data of the standard product applies except for the ambient conditions. Ambient conditions Relative humidity 100 %, condensation/frost permissible. No commissioning if condensation present. Biologically active substances, compliance with EN 60721-3-3 Class 3B2 mold and fungal spores (excluding fauna). The supplied plug covers must remain in place over the unused interfaces during operation! Chemically active substances, compliance with EN 60721-3-3 Class 3C4 incl. salt spray in accordance with EN60068-2-52 (degree of severity 3). The supplied plug covers must remain in place over the unused interfaces during operation! Mechanically active substances, compliance with EN 60721-3-3 Class 3S4 incl. sand, dust. The supplied plug covers must remain in place over the unused interfaces during operation! Air pressure (depending on the highest positive temperature range specified) 1 080 ... 795 hPa (-1 000 ... +2 000 m) see ambient temperature range 795 ... 658 hPa (+2000 ... +3500 m) derating 10 K658 ... 540 hPa (+3 500 ... +5 000 m) derating 20 K For technical documentation on SIPLUS, see: http://www.siemens.com/siplus-extreme 2/24 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels SIPLUS Basic Panels SIPLUS Basic Panels ■ Ordering data SIPLUS HMI KTP300 Basic mono PN Order No. 6AG1647-0AH11-2AX0 For areas with extreme medial exposure (conformal coating); ambient temperature -25 ... +60 °C SIPLUS HMI KTP400 Basic mono PN For areas with extreme medial exposure (conformal coating); ambient temperature -25 ... +60 °C 6AG1647-0AE11-4AX0 For areas with extreme medial exposure (conformal coating); ambient temperature 0 ... +50 °C 6AG1647-0AA11-2AX0 For areas with extreme medial exposure (conformal coating); ambient temperature -10 ... +60 °C SIPLUS HMI KTP600 Basic color PN Order No. SIPLUS HMI KTP1000 Basic Color DP SIPLUS HMI KTP1000 Basic Color PN 6AG1647-0AF11-4AX0 2 For areas with extreme medial exposure (conformal coating); ambient temperature 0 ... +50 °C 6AG1647-0AD11-2AX0 SIPLUS HMI TP1500 Basic Color PN 6AG1647-0AG11-4AX0 For areas with extreme medial exposure (conformal coating); ambient temperature 0 ... +50 °C Accessories See SIMATIC Basic Panels, from page 2/12 Additional information is available in the Internet under: http://www.siemens.com/simatic-basic-panels Note Do you require a specific modification to or supplement for the products described here? Look under "Customized products". We provide information there about additional and generally available sector products, and about the customer-specific modification and adaptation options. Siemens ST 80 / ST PC · 2013 2/25 © Siemens AG 2013 Operator panels Comfort Panels Comfort Panels – Standard ■ Overview 2 • Excellent HMI functionality for demanding applications • Widescreen TFT displays with 4", 7", 9", 12", 15", 19" and 22" diagonals (all 16 million colors) with up to 40% more visualization area as compared to the predecessor devices • Integrated high-end functionality with archives, scripts, PDF/Word/Excel viewer, Internet Explorer, Media Player and Web Server • Dimmable displays from 0 to 100% via PROFIenergy, via the HMI project or via a controller • Modern industrial design, cast aluminum fronts for 7" upwards • Upright installation for all touch devices • Optimal selection option: seven touch and five key versions are available • Data security in the event of a power failure for the device and for the SIMATIC HMI Memory Card • Innovative service and commissioning concept through second SD card (automatic backup) • Easy project transfer via standard cable (standard Ethernet cable, standard USB cable) • Maximum performance with short screen refresh times • Suitable for extremely harsh industrial environments thanks to extended approvals such as ATEX 2/22 and marine approvals • Wide range of communication options: PROFIBUS and PROFINET onboard; 2 x PROFINET with integrated switch for 7" models or larger; plus 1 x PROFINET with Gigabit support for 15" models or larger • All variants can be used as an OPC UA client or as an OPC DA server • Key-operated devices with LED in every function key and new text input mechanism, similar to the keypads of mobile phones • All keys have a service life of 2 million operations • Configuring with the WinCC engineering software of the TIA Portal ■ Technical specifications 6AV2124-2DC01-0AX0 6AV2124-0GC01-0AX0 6AV2124-0JC01-0AX0 6AV2124-0MC01-0AX0 SIMATIC HMI KTP400 Comfort SIMATIC HMI TP700 Comfort SIMATIC HMI TP900 Comfort SIMATIC HMI TP1200 Comfort Display Design of display TFT TFT TFT TFT Screen diagonal 4.3 in 7 in 9 in 12.1 in Number of colors 16 777 200 16 777 200 16 777 200 16 777 200 Resolution (pixels) • Horizontal image resolution • Vertical image resolution 480 272 800 480 800 480 1 280 800 Backlighting • MTBF backlighting (at 25 °C) • Dimmable backlight 80 000 h Yes; 0-100 % 80 000 h Yes; 0-100 % 80 000 h Yes; 0-100 % 80 000 h Yes; 0-100 % Control elements Keyboard fonts • Number of function keys 4 0 0 0 Touch operation • Design as touch screen Yes Yes Yes Yes Yes Yes Yes Yes Supply voltage Type of supply voltage DC DC DC DC Rated voltage/DC 24 V 24 V 24 V 24 V Memory Usable memory for user data 4 Mbyte 12 Mbyte 12 Mbyte 12 Mbyte Type of output Acoustics • Speaker No Yes Yes Yes Installation type/mounting Mounting in portrait format possible 2/26 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels Comfort Panels Comfort Panels – Standard ■ Technical specifications (continued) 6AV2124-2DC01-0AX0 6AV2124-0GC01-0AX0 6AV2124-0JC01-0AX0 6AV2124-0MC01-0AX0 SIMATIC HMI KTP400 Comfort SIMATIC HMI TP700 Comfort SIMATIC HMI TP900 Comfort SIMATIC HMI TP1200 Comfort Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Interfaces Number of RS 485 interfaces 1; RS 422/485 combined 1; RS 422/485 combined 1; RS 422/485 combined 1; RS 422/485 combined Number of USB interfaces 1; USB 2.0 2; USB 2.0 2; USB 2.0 2; USB 2.0 Number of USB Mini B interfaces 1; 5-pole 1; 5-pole 1; 5-pole 1; 5-pole Number of SD card slots 2 2 2 2 1 2 2 2 1 2 2 2 Protocols PROFINET Yes Yes Yes Yes IRT supported No Yes Yes Yes MRP supported No Yes Yes Yes PROFIBUS Yes Yes Yes Yes MPI Yes Yes Yes Yes Degree and class of protection Type of protection IP20 IP20 IP20 IP20 IP (at the front) IP65 IP65 IP65 IP65 Enclosure type 4x at the front Yes Yes Yes Yes Standards, approvals, certificates CE Yes Yes Yes Yes cULus Yes Yes Yes Yes GL Yes Yes Yes Yes ABS Yes Yes Yes Yes BV Yes Yes Yes Yes DNV Yes Yes Yes Yes LRS Yes Yes Yes Yes Class NK No; Available soon No; Available soon No; Available soon No; Available soon PRS No No No No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 0 °C 0 °C 0 °C 0 °C 50 °C 50 °C 50 °C 50 °C Relative humidity • max. relative humidity 90 % 90 % 90 % 90 % Configuration Configuration software • WinCC Comfort (TIA Portal) Yes; from V11 Yes; from V11 Yes; from V11 Yes; from V11 Time of day Clock • Hardware clock (real-time clock) • Battery-backed • Synchronizable Industrial Ethernet • Number of industrial Ethernet interfaces • Number of ports of the integrated switch Use in hazardous areas • ATEX Zone 2 • ATEX Zone 22 • cULus Class I Zone 2, Division 2 • FM Class I Division 2 Ambient conditions Operating temperature • Operation (vertical installation) - in vertical mounting position/ minimum - in vertical mounting position/ maximum Siemens ST 80 / ST PC · 2013 2 2/27 © Siemens AG 2013 Operator panels Comfort Panels Comfort Panels – Standard ■ Technical specifications (continued) 2 6AV2124-2DC01-0AX0 6AV2124-0GC01-0AX0 6AV2124-0JC01-0AX0 6AV2124-0MC01-0AX0 SIMATIC HMI KTP400 Comfort SIMATIC HMI TP700 Comfort SIMATIC HMI TP900 Comfort SIMATIC HMI TP1200 Comfort 32 32 32 32 Functionality under WinCC (TIA Portal) Applications/options • Internet Explorer • Pocket Word • Pocket Excel • PDF Viewer • Media Player • SIMATIC WinCC Sm@rtServer Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Visual Basic Scripts Yes Yes Yes Yes Task planner • time-controlled • task-controlled Yes Yes Yes Yes Yes Yes Yes Yes 2 000 50 4 000 200 4 000 200 4 000 200 256 Yes Yes 1 024 Yes Yes 1 024 Yes Yes 1 024 Yes Yes 300 2 Mbyte Yes 300 2 Mbyte Yes 300 2 Mbyte Yes 1 024 2 048 2 048 2 048 50 400 400 400 Images • Number of configurable images 500 500 500 500 Archiving • Number of archives per device 10 50 50 50 Security • Number of user groups • Number of users • SIMATIC Logon 50 50 Yes 50 50 Yes 50 50 Yes 50 50 Yes Logging through printer • Alarms • Report (shift log) • Hardcopy • Electronic print to file Yes Yes Yes Yes; pdf, html Yes Yes Yes Yes; pdf, html Yes Yes Yes Yes; pdf, html Yes Yes Yes Yes; pdf, html Transfer (upload/download) • MPI/PROFIBUS DP • USB • Ethernet Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Languages Online languages • Number of online/runtime languages With alarm logging system (incl. buffer and acknowledgment) • Number of bit messages • Number of analog messages • Message buffer - Number of entries - Circulating buffer - retentive Recipes • Number of recipes 100 • Size of internal recipe memory 512 kbyte Yes • Recipe memory expandable Variables • Number of variables per device • Number of variables per screen 2/28 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels Comfort Panels Comfort Panels – Standard ■ Technical specifications (continued) 6AV2124-2DC01-0AX0 6AV2124-0GC01-0AX0 6AV2124-0JC01-0AX0 6AV2124-0MC01-0AX0 SIMATIC HMI KTP400 Comfort SIMATIC HMI TP700 Comfort SIMATIC HMI TP900 Comfort SIMATIC HMI TP1200 Comfort Yes Yes Yes Yes Yes Yes No; With WinCC, subsequent version Yes Yes Yes Yes No Yes Yes Yes Yes No Yes Yes Yes Yes Yes Yes No; With WinCC, subsequent version Yes Yes Yes Yes No Yes Yes Yes Yes No Yes Yes Yes Yes Yes Yes No; With WinCC, subsequent version Yes Yes Yes Yes No Yes Yes Yes Yes No Yes Yes Yes Yes Yes Yes No; With WinCC, subsequent version Yes Yes Yes Yes No Yes Yes Yes Yes No I/O I/O devices • Printer • Multi Media Card • SD card • USB memory • Network camera Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Mechanics/material Type of housing (front) • Plastic • Aluminum Yes No No Yes No Yes No Yes Dimensions Width of the housing front 140 mm 214 mm 274 mm 330 mm Height of housing front 116 mm 158 mm 190 mm 241 mm Mounting cutout (W x H x D) • Mounting cutout, width • Mounting cutout, height 123 mm 99 mm 197 mm 141 mm 251 mm 166 mm 310 mm 221 mm Weight Weight without packaging 0.6 kg 1.4 kg 1.9 kg 2.8 kg Process coupling • S7-1200 • S7-1500 • S7-200 • S7-300/400 • LOGO! • Win AC • SIMOTION • • • • • • • • • • Allen Bradley (EtherNet/IP) Allen Bradley (DF1) Mitsubishi (MC TCP/IP) Mitsubishi (FX) OMRON (FINS TCP) OMRON (LINK/Multilink) Modicon (Modbus TCP/IP) Modicon (Modbus) OPC UA Client OPC UA Server 6AV2124-1DC01-0AX0 6AV2124-1GC01-0AX0 6AV2124-1JC01-0AX0 6AV2124-1MC01-0AX0 6AV2124-1QC02-0AX0 SIMATIC HMI KP400 Comfort SIMATIC HMI KP700 Comfort SIMATIC HMI KP900 Comfort SIMATIC HMI KP1200 Comfort SIMATIC HMI KP1500 Comfort Display Design of display TFT TFT TFT TFT TFT Screen diagonal 4.3 in 7 in 9 in 12.1 in 15.4 in Number of colors 16 777 200 16 777 200 16 777 200 16 777 200 16 777 200 Resolution (pixels) • Horizontal image resolution • Vertical image resolution 480 272 800 480 800 480 1 280 800 1 280 800 Backlighting • MTBF backlighting (at 25 °C) • Dimmable backlight 80 000 h Yes; 0-100 % 80 000 h Yes; 0-100 % 80 000 h Yes; 0-100 % 80 000 h Yes; 0-100 % 80 000 h Yes; 0-100 % Control elements Keyboard fonts • Number of function keys 8 24 26 34 36 Touch operation • Design as touch screen No No No No No No No No No No Supply voltage Type of supply voltage DC DC DC DC DC Rated voltage/DC 24 V 24 V 24 V 24 V 24 V Installation type/mounting Mounting in portrait format possible Siemens ST 80 / ST PC · 2013 2/29 2 © Siemens AG 2013 Operator panels Comfort Panels Comfort Panels – Standard ■ Technical specifications (continued) 2 6AV2124-1DC01-0AX0 6AV2124-1GC01-0AX0 6AV2124-1JC01-0AX0 6AV2124-1MC01-0AX0 6AV2124-1QC02-0AX0 SIMATIC HMI KP400 Comfort SIMATIC HMI KP700 Comfort SIMATIC HMI KP900 Comfort SIMATIC HMI KP1200 Comfort SIMATIC HMI KP1500 Comfort Memory Usable memory for user data 4 Mbyte 12 Mbyte 12 Mbyte 12 Mbyte 24 Mbyte Type of output Acoustics • Speaker No Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 1; RS 422/485 combined 1; RS 422/485 combined 1; RS 422/485 combined 1; RS 422/485 combined 1; RS 422/485 combined Number of USB interfaces 1; USB 2.0 2; USB 2.0 2; USB 2.0 2; USB 2.0 2; USB 2.0 Number of USB Mini B interfaces 1; 5-pole 1; 5-pole 1; 5-pole 1; 5-pole 1; 5-pole Number of SD card slots 2 2 2 2 2 1 2 2 2 3 1 2 2 2 2 Protocols PROFINET Yes Yes Yes Yes Yes IRT supported No Yes Yes Yes Yes MRP supported No Yes Yes Yes Yes PROFIBUS Yes Yes Yes Yes Yes MPI Yes Yes Yes Yes Yes Degree and class of protection Type of protection IP20 IP20 IP20 IP20 IP20 IP (at the front) IP65 IP65 IP65 IP65 IP65 Enclosure type 4x at the front Yes Yes Yes Yes Yes Standards, approvals, certificates CE Yes Yes Yes Yes Yes cULus Yes Yes Yes Yes Yes GL Yes Yes Yes Yes No ABS Yes Yes Yes Yes No BV Yes Yes Yes Yes No DNV Yes Yes Yes Yes No LRS Yes Yes Yes Yes No Class NK No; Available soon No; Available soon No; Available soon No; Available soon No PRS No No No No No No; Available soon No; Available soon Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes No No Yes Yes Yes Yes Yes Yes 0 °C 0 °C 0 °C 0 °C 0 °C 50 °C 50 °C 50 °C 50 °C 50 °C 90 % 90 % 90 % 90 % 90 % Time of day Clock • Hardware clock (real-time clock) • Battery-backed • Synchronizable Interfaces Number of RS 485 interfaces Industrial Ethernet • Number of industrial Ethernet interfaces • Number of ports of the integrated switch Use in hazardous areas • ATEX Zone 2 • ATEX Zone 22 • cULus Class I Zone 2, Division 2 • FM Class I Division 2 Ambient conditions Operating temperature • Operation (vertical installation) - in vertical mounting position/ minimum - in vertical mounting position/ maximum Relative humidity • max. relative humidity 2/30 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels Comfort Panels Comfort Panels – Standard ■ Technical specifications (continued) 6AV2124-1DC01-0AX0 6AV2124-1GC01-0AX0 6AV2124-1JC01-0AX0 6AV2124-1MC01-0AX0 6AV2124-1QC02-0AX0 SIMATIC HMI KP400 Comfort SIMATIC HMI KP700 Comfort SIMATIC HMI KP900 Comfort SIMATIC HMI KP1200 Comfort SIMATIC HMI KP1500 Comfort Yes; from V11 Yes; from V11 Yes; from V11 Yes; from V11 Yes; V11 SP2 or higher 32 32 32 32 32 Functionality under WinCC (TIA Portal) Applications/options • Internet Explorer • Pocket Word • Pocket Excel • PDF Viewer • Media Player • SIMATIC WinCC Sm@rtServer Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Visual Basic Scripts Yes Yes Yes Yes Yes Task planner • time-controlled • task-controlled Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 2 000 50 4 000 200 4 000 200 4 000 200 6 000 200 256 Yes Yes 1 024 Yes Yes 1 024 Yes Yes 1 024 Yes Yes 1 024 Yes Yes 300 2 Mbyte Yes 300 2 Mbyte Yes 300 2 Mbyte Yes 500 4 Mbyte Yes 1 024 2 048 2 048 2 048 4 096 50 400 400 400 400 Images • Number of configurable images 500 500 500 500 750 Archiving • Number of archives per device 10 50 50 50 50 Security • Number of user groups • Number of users • SIMATIC Logon 50 50 Yes 50 50 Yes 50 50 Yes 50 50 Yes 50 50 Yes Logging through printer • Alarms • Report (shift log) • Hardcopy • Electronic print to file Yes Yes Yes Yes; pdf, html Yes Yes Yes Yes; pdf, html Yes Yes Yes Yes; pdf, html Yes Yes Yes Yes; pdf, html Yes Yes Yes Yes; pdf, html Transfer (upload/download) • MPI/PROFIBUS DP • USB • Ethernet Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Configuration Configuration software • WinCC Comfort (TIA Portal) Languages Online languages • Number of online/runtime languages With alarm logging system (incl. buffer and acknowledgment) • Number of bit messages • Number of analog messages • Message buffer - Number of entries - Circulating buffer - retentive Recipes • Number of recipes 100 • Size of internal recipe memory 512 kbyte • Recipe memory expandable Yes Variables • Number of variables per device • Number of variables per screen Siemens ST 80 / ST PC · 2013 2/31 2 © Siemens AG 2013 Operator panels Comfort Panels Comfort Panels – Standard ■ Technical specifications (continued) 2 6AV2124-1DC01-0AX0 6AV2124-1GC01-0AX0 6AV2124-1JC01-0AX0 6AV2124-1MC01-0AX0 6AV2124-1QC02-0AX0 SIMATIC HMI KP400 Comfort SIMATIC HMI KP700 Comfort SIMATIC HMI KP900 Comfort SIMATIC HMI KP1200 Comfort SIMATIC HMI KP1500 Comfort Yes Yes Yes Yes Yes Yes No; With WinCC, subsequent version Yes Yes Yes Yes No Yes Yes Yes Yes No Yes Yes Yes Yes Yes Yes No; With WinCC, subsequent version Yes Yes Yes Yes No Yes Yes Yes Yes No Yes Yes Yes Yes Yes Yes No; With WinCC, subsequent version Yes Yes Yes Yes No Yes Yes Yes Yes No Yes Yes Yes Yes Yes Yes No; With WinCC, subsequent version Yes Yes Yes Yes No Yes Yes Yes Yes No Yes Yes Yes Yes Yes Yes No; With WinCC, subsequent version Yes Yes Yes Yes No Yes Yes Yes Yes No I/O I/O devices • Printer • Multi Media Card • SD card • USB memory • Network camera Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Mechanics/material Type of housing (front) • Plastic • Aluminum Yes No No Yes No Yes No Yes No Yes Dimensions Width of the housing front 152 mm 308 mm 362 mm 454 mm 483 mm Height of housing front 188 mm 204 mm 230 mm 289 mm 310 mm Mounting cutout (W x H x D) • Mounting cutout, width • Mounting cutout, height 135 mm 171 mm 281 mm 177 mm 338 mm 206 mm 434 mm 269 mm 450 mm 291 mm Weight Weight without packaging 0.8 kg 2.2 kg 2.7 kg 4.4 kg 5.4 kg Process coupling • S7-1200 • S7-1500 • S7-200 • S7-300/400 • LOGO! • Win AC • SIMOTION • • • • • • • • • • Allen Bradley (EtherNet/IP) Allen Bradley (DF1) Mitsubishi (MC TCP/IP) Mitsubishi (FX) OMRON (FINS TCP) OMRON (LINK/Multilink) Modicon (Modbus TCP/IP) Modicon (Modbus) OPC UA Client OPC UA Server 2/32 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels Comfort Panels Comfort Panels – Standard ■ Technical specifications (continued) 6AV2124-0QC02-0AX0 6AV2124-0UC02-0AX0 6AV2124-0XC02-0AX0 SIMATIC HMI TP1500 Comfort SIMATIC HMI TP1900 Comfort SIMATIC HMI TP2200 Comfort Display Design of display TFT TFT TFT Screen diagonal 15.4 in 18.5 in 21.5 in Number of colors 16 777 200 16 777 200 16 777 200 Resolution (pixels) • Horizontal image resolution • Vertical image resolution 1 280 800 1 366 768 1 920 1 080 Backlighting • MTBF backlighting (at 25 °C) • Dimmable backlight 80 000 h Yes; 0-100 % 50 000 h Yes; 0-100 % 30 000 h Yes; 0-100 % Control elements Keyboard fonts • Number of function keys 0 0 0 Touch operation • Design as touch screen Yes Yes Yes Yes Yes Yes Supply voltage Type of supply voltage DC DC DC Rated voltage/DC 24 V 24 V 24 V Memory Usable memory for user data 24 Mbyte 24 Mbyte 24 Mbyte Type of output Acoustics • Speaker Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Interfaces Number of RS 485 interfaces 1; RS 422/485 combined 1; RS 422/485 combined 1; RS 422/485 combined Number of USB interfaces 2; USB 2.0 2; USB 2.0 2; USB 2.0 Number of USB Mini B interfaces 1; 5-pole 1; 5-pole 1; 5-pole Number of SD card slots 2 2 2 3 3 3 2 2 2 Protocols PROFINET Yes Yes Yes IRT supported Yes Yes Yes MRP supported Yes Yes Yes PROFIBUS Yes Yes Yes MPI Yes Yes Yes Degree and class of protection Type of protection IP20 IP20 IP20 IP (at the front) IP65 IP65 IP65 Enclosure type 4x at the front Yes Yes Yes Installation type/mounting Mounting in portrait format possible Time of day Clock • Hardware clock (real-time clock) • Battery-backed • Synchronizable Industrial Ethernet • Number of industrial Ethernet interfaces • Number of ports of the integrated switch Siemens ST 80 / ST PC · 2013 2 2/33 © Siemens AG 2013 Operator panels Comfort Panels Comfort Panels – Standard ■ Technical specifications (continued) 2 6AV2124-0QC02-0AX0 6AV2124-0UC02-0AX0 6AV2124-0XC02-0AX0 SIMATIC HMI TP1500 Comfort SIMATIC HMI TP1900 Comfort SIMATIC HMI TP2200 Comfort Standards, approvals, certificates CE Yes Yes Yes cULus Yes Yes Yes GL No No No ABS No No No BV No No No DNV No No No LRS No No No Class NK No No No PRS No No No No No Yes No No Yes No No Yes Yes Yes Yes 0 °C 0 °C 0 °C 50 °C 45 °C 45 °C Relative humidity • max. relative humidity 90 % 90 % 90 % Configuration Configuration software • WinCC Comfort (TIA Portal) Yes; V11 SP2 or higher Yes; V11 SP2 or higher Yes; V11 SP2 or higher 32 32 32 Functionality under WinCC (TIA Portal) Applications/options • Internet Explorer • Pocket Word • Pocket Excel • PDF Viewer • Media Player • SIMATIC WinCC Sm@rtServer Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Visual Basic Scripts Yes Yes Yes Task planner • time-controlled • task-controlled Yes Yes Yes Yes Yes Yes 6 000 200 6 000 200 6 000 200 1 024 Yes Yes 1 024 Yes Yes 1 024 Yes Yes 500 4 Mbyte Yes 500 4 Mbyte Yes 4 096 4 096 4 096 400 400 400 Use in hazardous areas • ATEX Zone 2 • ATEX Zone 22 • cULus Class I Zone 2, Division 2 • FM Class I Division 2 Ambient conditions Operating temperature • Operation (vertical installation) - in vertical mounting position/ minimum - in vertical mounting position/ maximum Languages Online languages • Number of online/runtime languages With alarm logging system (incl. buffer and acknowledgment) • Number of bit messages • Number of analog messages • Message buffer - Number of entries - Circulating buffer - retentive Recipes • Number of recipes 500 • Size of internal recipe memory 4 Mbyte • Recipe memory expandable Yes Variables • Number of variables per device • Number of variables per screen 2/34 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels Comfort Panels Comfort Panels – Standard ■ Technical specifications (continued) 6AV2124-0QC02-0AX0 6AV2124-0UC02-0AX0 6AV2124-0XC02-0AX0 SIMATIC HMI TP1500 Comfort SIMATIC HMI TP1900 Comfort SIMATIC HMI TP2200 Comfort Images • Number of configurable images 750 750 750 Archiving • Number of archives per device 50 50 50 Security • Number of user groups • Number of users • SIMATIC Logon 50 50 Yes 50 50 Yes 50 50 Yes Logging through printer • Alarms • Report (shift log) • Hardcopy • Electronic print to file Yes Yes Yes Yes; pdf, html Yes Yes Yes Yes; pdf, html Yes Yes Yes Yes; pdf, html Transfer (upload/download) • MPI/PROFIBUS DP • USB • Ethernet Yes Yes Yes Yes Yes Yes Yes Yes Yes Process coupling • S7-1200 • S7-1500 • S7-200 • S7-300/400 • LOGO! • Win AC • SIMOTION • Allen Bradley (EtherNet/IP) • Allen Bradley (DF1) • Mitsubishi (MC TCP/IP) • Mitsubishi (FX) • OMRON (FINS TCP) • OMRON (LINK/Multilink) • Modicon (Modbus TCP/IP) • Modicon (Modbus) • OPC UA Client • OPC UA Server Yes Yes Yes Yes Yes Yes No; With WinCC, subsequent version Yes Yes Yes Yes No Yes Yes Yes Yes No Yes Yes Yes Yes Yes Yes No; With WinCC, subsequent version Yes Yes Yes Yes No Yes Yes Yes Yes No Yes Yes Yes Yes Yes Yes No; With WinCC, subsequent version Yes Yes Yes Yes No Yes Yes Yes Yes No I/O I/O devices • Printer • Multi Media Card • SD card • USB memory • Network camera Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Mechanics/material Type of housing (front) • Plastic • Aluminum No Yes No Yes No Yes Dimensions Width of the housing front 415 mm 483 mm 560 mm Height of housing front 310 mm 337 mm 380 mm Mounting cutout (W x H x D) • Mounting cutout, width • Mounting cutout, height 396 mm 291 mm 465 mm 319 mm 542 mm 362 mm Weight Weight without packaging 5.2 kg 6.5 kg 7.1 kg Siemens ST 80 / ST PC · 2013 2 2/35 © Siemens AG 2013 Operator panels Comfort Panels Comfort Panels – Standard ■ Ordering data Order No. SIMATIC HMI Comfort Panels, Key and Touch SIMATIC HMI KTP400 Comfort 6AV2124-2DC01-0AX0 SIMATIC HMI Comfort Panels, Touch 2 SIMATIC HMI TP700 Comfort 6AV2124-0GC01-0AX0 SIMATIC HMI TP900 Comfort 6AV2124-0JC01-0AX0 SIMATIC HMI TP1200 Comfort 6AV2124-0MC01-0AX0 SIMATIC HMI TP1500 Comfort 6AV2124-0QC02-0AX0 SIMATIC HMI TP1900 Comfort 6AV2124-0UC02-0AX0 SIMATIC HMI TP2200 Comfort 6AV2124-0XC02-0AX0 SIMATIC HMI Comfort Panels, Key SIMATIC HMI KP400 Comfort 6AV2124-1DC01-0AX0 SIMATIC HMI KP700 Comfort 6AV2124-1GC01-0AX0 SIMATIC HMI KP900 Comfort 6AV2124-1JC01-0AX0 SIMATIC HMI KP1200 Comfort 6AV2124-1MC01-0AX0 SIMATIC HMI KP1500 Comfort 6AV2124-1QC02-0AX0 2/36 Siemens ST 80 / ST PC · 2013 Order No. Starter kits for SIMATIC HMI Comfort Panels Consisting of: the respective SIMATIC HMI Comfort Panel, SIMATIC WinCC Comfort, Ethernet cable, 2 m SIMATIC HMI memory card 2 GB 10 protective films for touch screen devices Starter kit for SIMATIC HMI KTP400 Comfort, Key and Touch 6AV2181-4DB20-0AX0 Starter kit for SIMATIC HMI TP700 Comfort, Touch 6AV2181-4GB00-0AX0 Starter kit for SIMATIC HMI TP900 Comfort, Touch 6AV2181-4JB00-0AX0 Starter kit for SIMATIC HMI TP1200 Comfort, Touch 6AV2181-4MB00-0AX0 Starter kit for SIMATIC HMI TP1500 Comfort, Touch 6AV2181-4QB00-0AX0 Starter kit for SIMATIC HMI TP1900 Comfort, Touch 6AV2181-4UB00-0AX0 Starter kit for SIMATIC HMI TP2200 Comfort, Touch 6AV2181-4XB00-0AX0 Starter kit for SIMATIC HMI KP400 Comfort, Key 6AV2181-4DB10-0AX0 Starter kit for SIMATIC HMI KP700 Comfort, Key 6AV2181-4GB10-0AX0 Starter kit for SIMATIC HMI KP900 Comfort, Key 6AV2181-4JB10-0AX0 Starter kit for SIMATIC HMI KP1200 Comfort, Key 6AV2181-4MB10-0AX0 Starter kit for SIMATIC HMI KP1500 Comfort, Key 6AV2181-4QB10-0AX0 Accessories See HMI accessories, from page 2/96 © Siemens AG 2013 Operator panels Comfort Panels Comfort Panels – Standard ■ Dimensional drawings 2 219 241 140 158 138.8 All dimensions in mm. For installation cutout, see technical specifications. 32.5 214 32.5 330 62.8 64.3 69 196 70.5 G_ST80_XX_00449 308 274 G_ST80_XX_00451 182 289 310 164 138.8 TP1200 Comfort 190 TP700 Comfort 194.7 32.5 47.6 415 63.1 TP900 Comfort 79.3 G_ST80_XX_00511 194.7 73.1 69.3 G_ST80_XX_00450 249 281 394 TP1500 Comfort Siemens ST 80 / ST PC · 2013 2/37 © Siemens AG 2013 Operator panels Comfort Panels Comfort Panels – Standard 483 170 188 182 337 2 317 98 ■ Dimensional drawings (continued) 47.6 18 73.1 152 48 79.3 134 463 308 47.6 69 280 79.3 TP2200 Comfort 2/38 Siemens ST 80 / ST PC · 2013 G_ST80_XX_00513 194.7 281 138.8 62.8 73.1 540 32.5 KP700 Comfort G_ST80_XX_00445 560 176 204 182 360 KP400 Comfort 380 TP1900 Comfort G_ST80_XX_00444 G_ST80_XX_00512 281 55.8 © Siemens AG 2013 Operator panels Comfort Panels Comfort Panels – Standard 182 289 310 47.6 483 32.5 62.8 73.1 69 79.3 G_ST80_XX_00446 336 2 194.7 281 448 KP1500 Comfort 140 454 98 116 267 289 138.8 KP900 Comfort G_ST80_XX_00510 362 204 138.8 230 ■ Dimensional drawings (continued) 18 32.5 48.6 64.5 54.8 70.5 122 KP1200 Comfort G_ST80_XX_00448 G_ST80_XX_00447 432 194.7 KTP400 Comfort ■ More information Additional information is available on the Internet at: http://www.siemens.com/simatic-comfort-panels You can find an overview of approved printers, supply sources and printer settings on the Internet at: http://support.automation.siemens.com/WW/view/en/11376409 Note Do you need a specific modification or extension to the products described here? If so, refer to "Customized Automation". There you will find information about additional and generally available sector-specific products as well as options for customer-specific modification and adaptation. Siemens ST 80 / ST PC · 2013 2/39 © Siemens AG 2013 Operator panels SIPLUS Comfort Panels SIPLUS Comfort Panels ■ Overview 2 • Excellent HMI functionality for demanding applications • Widescreen TFT displays with 4", 7", 9", 12", 15", 19" and 22" diagonals (all 16 million colors) with up to 40% more visualization area as compared to the predecessor devices • Integrated high-end functionality with archives, scripts, PDF/Word/Excel viewer, Internet Explorer, Media Player • Dimmable displays from 0 to 100% via PROFIenergy, via the HMI project or via a controller • Modern industrial design, cast aluminum fronts for 7" upwards • Upright installation for all touch devices • Optimal selection option: seven touch and five key versions are available 2/40 Siemens ST 80 / ST PC · 2013 • Data security in the event of a power failure for the device and for the SIMATIC HMI Memory Card • Innovative service and commissioning concept through second SD card (automatic backup) • Easy project transfer via standard cable (standard Ethernet cable, standard USB cable) • Maximum performance with short screen refresh times • Suitable for extremely harsh industrial environments thanks to extended approvals such as ATEX 2/22 • Wide range of communication options: PROFIBUS and PROFINET onboard; 2x PROFINET with integrated switch for 7" models or larger; plus 1 additional PROFINET with Gigabit support for 15" models or larger • All variants can be used as an OPC UA client or as an OPC DA server • Key-operated devices with LED in every function key and new text input mechanism, similar to the keypads of mobile phones • Key-operated devices with stamped keys for optimum tactile feedback • All keys have a service life of 2 million operations • Configuring with the WinCC engineering software of the TIA Portal Note: SIPLUS extreme products are based on Siemens Industry standard products. The contents listed here were taken from the respective standard products. SIPLUS extreme-specific information was added. © Siemens AG 2013 Operator panels SIPLUS Comfort Panels SIPLUS Comfort Panels ■ Technical specifications Ambient conditions Operating temperature • Operation (vertical installation) - in vertical mounting position/ minimum - in vertical mounting position/ maximum Extended ambient conditions • Relative humidity - With condensation/ maximum/tested in accordance with IEC 60068-2-38 • Resistance - to biologically active substances - to chemically active substances - to mechanically active substances Ambient conditions Operating temperature • Operation (vertical installation) - in vertical mounting position/ minimum - in vertical mounting position/ maximum Extended ambient conditions • Relative humidity - With condensation/ maximum/tested in accordance with IEC 60068-2-38 • Resistance - to biologically active substances - to chemically active substances - to mechanically active substances 6AG1124-2DC01-4AX0 6AG1124-0GC01-4AX0 6AG1124-0JC01-4AX0 6AG1124-0MC01-4AX0 SIPLUS HMI KTP400 Comfort SIPLUS HMI TP700 Comfort SIPLUS HMI TP900 Comfort SIPLUS HMI TP1200 Comfort 0 °C 0 °C 0 °C 0 °C 50 °C 50 °C 50 °C 50 °C 100 % 100 % 100 % 100 % Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 2 6AG1124-1DC01-4AX0 6AG1124-1GC01-4AX0 6AG1124-1JC01-4AX0 6AG1124-1MC01-4AX0 6AG1124-1QC02-4AX0 SIPLUS HMI KTP400 Comfort SIPLUS HMI KP700 Comfort SIPLUS HMI KP900 Comfort SIPLUS HMI KP1200 Comfort SIPLUS HMI KP1500 Comfort 0 °C 0 °C 0 °C 0 °C 0 °C 50 °C 50 °C 50 °C 50 °C 50 °C 100 % 100 % 100 % 100 % 100 % Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Siemens ST 80 / ST PC · 2013 2/41 © Siemens AG 2013 Operator panels SIPLUS Comfort Panels SIPLUS Comfort Panels ■ Technical specifications (continued) 2 Ambient conditions Operating temperature • Operation (vertical installation) - in vertical mounting position/ minimum - in vertical mounting position/ maximum Extended ambient conditions • Relative humidity - With condensation/ maximum/tested in accordance with IEC 60068-2-38 • Resistance - to biologically active substances - to chemically active substances - to mechanically active substances 2/42 6AG1124-0QC02-4AX0 6AG1124-0UC02-4AX0 6AG1124-0XC02-4AX0 SIPLUS HMI TP1500 Comfort SIPLUS HMI TP1900 Comfort SIPLUS HMI TP2200 Comfort 0 °C 0 °C 0 °C 50 °C 45 °C 45 °C 100 % 100 % 100 % Yes Yes Yes Yes Yes Yes Yes Yes Yes Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels SIPLUS Comfort Panels SIPLUS Comfort Panels ■ Ordering data Order No. SIPLUS HMI KTP400 Comfort ■ More information Additional information is available on the Internet at: http://www.siemens.com/simatic-comfort-panels SIPLUS HMI Comfort Panels, Keys and Touch 6AG1124-2DC01-4AX0 SIPLUS HMI Comfort Panels, Touch SIPLUS HMI TP700 Comfort 6AG1124-0GC01-4AX0 SIPLUS HMI TP900 Comfort 6AG1124-0JC01-4AX0 SIPLUS HMI TP1200 Comfort 6AG1124-1MC01-4AX0 SIPLUS HMI TP1500 Comfort 6AG1124-0QC02-4AX0 SIPLUS HMI TP1900 Comfort 6AG1124-0UC02-4AX0 SIPLUS HMI TP2200 Comfort 6AG1124-0XC02-4AX0 You can find an overview of approved printers, supply sources and printer settings on the Internet at: http://support.automation.siemens.com/WW/view/en/11376409 Note Do you need a specific modification or extension to the products described here? If so, refer to "Customized Automation". There you will find information about additional and generally available sector-specific products as well as options for customer-specific modification and adaptation. SIPLUS HMI Comfort Panels, Keys SIPLUS HMI KP400 Comfort 6AG1124-1DC01-4AX0 SIPLUS HMI KP700 Comfort 6AG1124-1GC01-4AX0 SIPLUS HMI KP900 Comfort 6AG1124-1JC01-4AX0 SIPLUS HMI KP1200 Comfort 6AG1124-1MC01-4AX0 SIPLUS HMI KP1500 Comfort 6AG1124-1QC02-4AX0 Accessories See HMI accessories, from page 2/26 Siemens ST 80 / ST PC · 2013 2/43 2 © Siemens AG 2013 Operator panels Mobile Panels Mobile Panels ■ Overview 2 SIMATIC Mobile Panel • Mobile operator panel for direct operator control of the plant and machine from any point • Supports an optimum view of the workpiece or process and, at the same time, direct access and visual contact with the operator panel • Versatile use thanks to easy unplugging and replugging during normal operation (Mobile Panel 177 and Mobile Panel 277) or • Wireless freedom (Mobile Panel 277(F) IWLAN) • Pixel-graphics, high-luminance color display with touch screen (analog/resistive) • PROFIBUS or PROFINET communication, PROFINET over WLAN for Mobile Panel 277(F) IWLAN • Freely-configurable function keys with customized labels (with LED) (not for Mobile Panel 277 10") SIMATIC Mobile Panel 177 and SIMATIC Mobile Panel 277 • Two three-stage acknowledgement buttons; Optional versions include: - STOP button - STOP button, handwheel, key-operated switch and illuminated pushbutton (not for Mobile Panel 277 10") • Communication is supported via a serial link, MPI/PROFIBUS or PROFINET • Connection point recognition for local identification of the device based on the connection point ID • Fast system availability after plugging into the connection boxes • Connection to the controller and power supply is made via the connection box and the connecting cable 2/44 Siemens ST 80 / ST PC · 2013 SIMATIC Mobile Panel 277(F) IWLAN • Wireless, mobile operator panel for flexible and locationindependent system and machine operation • WLAN communication in accordance with IEEE 802.11 (a/b/g/h) and PROFINET support • Powerful batteries and flexible concept for changing permit battery replacement "on the fly" without interrupting operation • Effective range limitation and the local identification of the device by using transponder technology • Low-cost, safety-related mobile operator control and monitoring via RFID technology (MOBY D) for plants with pre-installed safety resources (e.g. robot cells) • Optional variants with: Handwheel, key switch and illuminated pushbutton • Fail-safe operator controls of the SIMATIC Mobile Panel 277F IWLAN using PROFIsafe: - Two three-stage acknowledgment buttons - Emergency stop button IWLAN Access Points SCALANCE W for SIMATIC Mobile Panel 277(F) IWLAN • The Access Points of the product line SCALANCE W-780 are ideally suited for setting up Industrial Wireless LAN (IWLAN) radio networks for 2.4 GHz and 5 GHz with data rates of up to 54 Mbps; they can be used for all applications that require a high degree of operational reliability, even under extremely harsh ambient conditions • Suitable for any application: - SCALANCE W-788 for cabinet-free installation - SCALANCE W-786 for cabinet-free installation, also with integral antennas - SCALANCE W-784 for installation in control cabinets or integration into devices • Wireless communication suitable for use in applications with high real-time and reliability requirements, such as PROFINET, PROFIsafe or video • Standard-compliant thanks to IEEE 802.11 support, additional functional expansions especially for use with increased reliability • Effective encryption mechanisms protect against unauthorized access, spying, tapping, and corruption • The SINEMA E engineering tool, wizards and online help support planning, simulation, configuration and documentation; easy management with the web server and SNMP • Fast commissioning of the Access Points thanks to the optional swap medium PRESET-PLUG and fast device replacement in the event of a fault thanks to the optional swap medium C-PLUG (Configuration Plug) • Accessories such as antennas, connectors, cables incl. RCoax cables (radiating cables) that are tuned to one another for a reliable radio link. © Siemens AG 2013 Operator panels Mobile Panels — 170 series SIMATIC Mobile Panel 177 ■ Overview 2 SIMATIC Mobile Panel 177 ■ Technical specifications 6AV6645-0AA01-0AX0 6AV6645-0AB01-0AX0 6AV6645-0AC01-0AX0 with integrated acknowledgment button with integrated acknowledgment button and STOP button with integrated acknowledgment button, STOP button, handwheel, keyswitch and illuminated pushbutton Display Size 5.7" (121 mm x 92 mm) 5.7" (121 mm x 92 mm) 5.7" (121 mm x 92 mm) Display type STN, 256 colors STN, 256 colors STN, 256 colors Resolution (pixels) • Resolution (WxH in pixel) 320 x 240 320 x 240 320 x 240 Backlighting • MTBF backlighting (at 25 °C) • MTBF backlighting (at 25 °C) about 50,000 hours 50 000 h about 50,000 hours 50 000 h about 50,000 hours 50 000 h Control elements Operating options Keys and Touch Keys and Touch Keys and Touch Function keys, programmable 14 function keys, 8 with LEDs 14 function keys, 8 with LEDs 14 function keys, 8 with LEDs Keyboard fonts • System keys 0 0 0 Touch operation • Touch screen Analog, resistive Analog, resistive Analog, resistive Special operator controls • Stop button • Acknowledgement button • Key-operated switch • Illuminated pushbutton • Handwheel No Yes No No No Yes Yes No No No Yes Yes Yes Yes Yes Supply voltage Supply voltage via connection box via connection box via connection box Processor Processor RISC 32-bit, 200 MHz RISC 32-bit, 200 MHz RISC 32-bit, 200 MHz Memory Type Flash / RAM Flash / RAM Flash / RAM 2048 KB of usable memory for user data / no user memory for options 2048 KB of usable memory for user data / no user memory for options 2048 KB of usable memory for user data / no user memory for options maximum buffer time 10 min maximum buffer time 10 min maximum buffer time 10 min Usable memory for user data Battery Backup battery • Battery operation Siemens ST 80 / ST PC · 2013 2/45 © Siemens AG 2013 Operator panels Mobile Panels — 170 series SIMATIC Mobile Panel 177 ■ Technical specifications (continued) 2 6AV6645-0AA01-0AX0 6AV6645-0AB01-0AX0 6AV6645-0AC01-0AX0 with integrated acknowledgment button with integrated acknowledgment button and STOP button with integrated acknowledgment button, STOP button, handwheel, keyswitch and illuminated pushbutton Interfaces Interfaces 1 x RS422, 1 x RS485 (max. 12 Mbit/s) 1 x RS422, 1 x RS485 (max. 12 Mbit/s) 1 x RS422, 1 x RS485 (max. 12 Mbit/s) USB port No No No Number of USB interfaces 0 0 0 PC card slot No No No CF card slot No No No SD card slot No Multimedia card/SD card slot combined combined combined Industrial Ethernet • Industrial Ethernet interface No No No Degree and class of protection IP65 enclosure Yes Yes Yes Standards, approvals, certificates Certifications CE, cULus, C-TICK, SIBE CE, cULus, C-TICK, SIBE CE, cULus, C-TICK, SIBE CE Yes Yes Yes cULus Yes Yes Yes C-TICK Yes Safety category according to EN954-1 Safety category according to EN954-1 (acknowledgment button, STOP button if present) 3 Safety category according to EN954-1 (acknowledgment button, STOP button if present) 3 Safety category according to EN954-1 (acknowledgment button, STOP button if present) 3 d d d Ambient conditions Drop height 1.5 m 1.5 m 1.5 m Operating temperature • Operation 0 °C to +40 °C 0 °C to +40 °C 0 °C to +40 °C Storage/transport temperature • Transport, storage -20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C Relative humidity • max. relative humidity 80 % 80 % 80 % Operating systems Operating system Windows CE Windows CE Windows CE 5 5 5 Functionality under WinCC (TIA Portal) Libraries Yes Yes Yes Task planner Yes Yes Yes With alarm logging system (incl. buffer and acknowledgment) • Number of messages • Bit messages • Analog messages 2 000 Yes Yes 2 000 Yes Yes 2 000 Yes Yes Recipes • Number of recipes • Data records per recipe • Entries per data record • Recipe memory 100 200 200 32 KB integrated Flash, expandable 100 200 200 32 KB integrated Flash, expandable 100 200 200 32 KB integrated Flash, expandable Highest safety class achievable in safety mode • Performance Level in accordance with EN ISO 13849-1 Languages Online languages • Number of online/runtime languages 2/46 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels Mobile Panels — 170 series SIMATIC Mobile Panel 177 ■ Technical specifications (continued) Variables • Number of variables per device • Limit values • Multiplexing 6AV6645-0AA01-0AX0 6AV6645-0AB01-0AX0 6AV6645-0AC01-0AX0 with integrated acknowledgment button with integrated acknowledgment button and STOP button with integrated acknowledgment button, STOP button, handwheel, keyswitch and illuminated pushbutton 1 024 1 024 1 024 Yes Yes Yes Yes Yes Yes 500 500 500 2,500 text elements Bit maps, vector graphics 2,500 text elements Bit maps, vector graphics 2,500 text elements Bit maps, vector graphics With SIMATIC S7 Diagrams, bar graphs, sliders, invisible buttons With SIMATIC S7 Diagrams, bar graphs, sliders, invisible buttons With SIMATIC S7 Diagrams, bar graphs, sliders, invisible buttons 300 300 300 100 100 100 0 0 0 Security • Number of user groups • Number of user rights • Password export/import 50 32 Yes 50 32 Yes 50 32 Yes Data carrier support • PC card • CF card No No No No No No Logging through printer • Recording/Printing - - - MPI/PROFIBUS DP, serial, automatic transfer recognition MPI/PROFIBUS DP, serial, automatic transfer recognition MPI/PROFIBUS DP, serial, automatic transfer recognition • S7-1200 • S7-1500 S5, S7-200, S7- 300/400, TI 505, Win AC, SINUMERIK, SIMOTION, Allen Bradley (DF1), Allen Bradley (DF485), Mitsubishi (FX), OMRON (LINK/Multilink), Modicon (Modbus), further non-Siemens drivers, see chapter "System interfaces" Yes Yes S5, S7-200, S7- 300/400, TI 505, Win AC, SINUMERIK, SIMOTION, Allen Bradley (DF1), Allen Bradley (DF485), Mitsubishi (FX), OMRON (LINK/Multilink), Modicon (Modbus), further non-Siemens drivers, see chapter "System interfaces" Yes Yes S5, S7-200, S7- 300/400, TI 505, Win AC, SINUMERIK, SIMOTION, Allen Bradley (DF1), Allen Bradley (DF485), Mitsubishi (FX), OMRON (LINK/Multilink), Modicon (Modbus), further non-Siemens drivers, see chapter "System interfaces" Yes Yes Expandability/openness • Open Platform Program Yes Yes Yes I/O I/O devices • Multi Media Card Yes Yes Yes Mechanics/material Type of housing (front) Plastic Plastic Plastic Dimensions Housing diameter/depth (mm) Dia 245 mm / D 58 mm Dia 245 mm / D 58 mm Dia 245 mm / D 58 mm Weight Weight 1.3 kg 1.3 kg 1.3 kg Images • Number of configurable images Image objects • Text objects • Graphics object Complex image objects • Status/control • dynamic objects Lists • Number of text lists per project • Number of graphics lists per project Archiving • Number of archives per device Transfer (upload/download) • Transfer of configuration Process coupling • Connection to controller Siemens ST 80 / ST PC · 2013 2 2/47 © Siemens AG 2013 Operator panels Mobile Panels — 170 series SIMATIC Mobile Panel 177 ■ Technical specifications (continued) 2 6AV6645-0BA01-0AX0 6AV6645-0BB01-0AX0 6AV6645-0BC01-0AX0 with integrated acknowledgment button with integrated acknowledgment button and STOP button with integrated acknowledgment button, STOP button, handwheel, keyswitch and illuminated pushbutton Display Size 5.7" (121 mm x 92 mm) 5.7" (121 mm x 92 mm) 5.7" (121 mm x 92 mm) Display type STN, 256 colors STN, 256 colors STN, 256 colors Resolution (pixels) • Resolution (WxH in pixel) 320 x 240 320 x 240 320 x 240 Backlighting • MTBF backlighting (at 25 °C) • MTBF backlighting (at 25 °C) about 50,000 hours 50 000 h about 50,000 hours 50 000 h about 50,000 hours 50 000 h Control elements Operating options Keys and Touch Keys and Touch Keys and Touch Function keys, programmable 14 function keys, 8 with LEDs 14 function keys, 8 with LEDs 14 function keys, 8 with LEDs Keyboard fonts • System keys 0 0 0 Touch operation • Touch screen Analog, resistive Analog, resistive Analog, resistive Special operator controls • Stop button • Acknowledgement button • Key-operated switch • Illuminated pushbutton • Handwheel No Yes No No No Yes Yes No No No Yes Yes Yes Yes Yes Supply voltage Supply voltage via connection box via connection box via connection box Processor Processor RISC 32-bit, 200 MHz RISC 32-bit, 200 MHz RISC 32-bit, 200 MHz Memory Type Flash / RAM Flash / RAM Flash / RAM 2048 KB of usable memory for user data / no user memory for options 2048 KB of usable memory for user data / no user memory for options 2048 KB of usable memory for user data / no user memory for options Battery Backup battery • Battery operation maximum buffer time 10 min maximum buffer time 10 min maximum buffer time 10 min Interfaces Interfaces 1 x RS485, 1 x Ethernet (RJ45) 1 x RS485, 1 x Ethernet (RJ45) 1 x RS485, 1 x Ethernet (RJ45) USB port No No No Number of USB interfaces 0 0 0 PC card slot No No No CF card slot No No No Multimedia card/SD card slot combined combined combined Industrial Ethernet • Industrial Ethernet interface 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) Protocols PROFINET Yes Yes Yes Yes Yes Yes Yes Yes Yes Usable memory for user data Supports protocol for PROFINET IO Degree and class of protection IP65 enclosure 2/48 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels Mobile Panels — 170 series SIMATIC Mobile Panel 177 ■ Technical specifications (continued) 6AV6645-0BA01-0AX0 6AV6645-0BB01-0AX0 6AV6645-0BC01-0AX0 with integrated acknowledgment button with integrated acknowledgment button and STOP button with integrated acknowledgment button, STOP button, handwheel, keyswitch and illuminated pushbutton Standards, approvals, certificates Certifications CE, cULus, C-TICK, SIBE CE, cULus, C-TICK, SIBE CE, cULus, C-TICK, SIBE CE Yes Yes Yes cULus Yes Yes Yes Safety category according to EN954-1 Safety category according to EN954-1 (acknowledgment button, STOP button if present) 3 Safety category according to EN954-1 (acknowledgment button, STOP button if present) 3 Safety category according to EN954-1 (acknowledgment button, STOP button if present) 3 d d d Ambient conditions Drop height 1.5 m 1.5 m 1.5 m Operating temperature • Operation 0 °C to +40 °C 0 °C to +40 °C 0 °C to +40 °C Storage/transport temperature • Transport, storage -20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C Relative humidity • max. relative humidity 80 % 80 % 80 % Operating systems Operating system Windows CE Windows CE Windows CE 5 5 5 Functionality under WinCC (TIA Portal) Libraries Yes Yes Yes Task planner Yes Yes Yes With alarm logging system (incl. buffer and acknowledgment) • Number of messages • Bit messages • Analog messages 2 000 Yes Yes 2 000 Yes Yes 2 000 Yes Yes Recipes • Number of recipes • Data records per recipe • Entries per data record • Recipe memory 100 200 200 32 KB integrated Flash, expandable 100 200 200 32 KB integrated Flash, expandable 100 200 200 32 KB integrated Flash, expandable 1 024 1 024 1 024 Yes Yes Yes Yes Yes Yes 500 500 500 2,500 text elements Bit maps, vector graphics 2,500 text elements Bit maps, vector graphics 2,500 text elements Bit maps, vector graphics With SIMATIC S7 Diagrams, bar graphs, sliders, invisible buttons With SIMATIC S7 Diagrams, bar graphs, sliders, invisible buttons With SIMATIC S7 Diagrams, bar graphs, sliders, invisible buttons Highest safety class achievable in safety mode • Performance Level in accordance with EN ISO 13849-1 Languages Online languages • Number of online/runtime languages Variables • Number of variables per device • Limit values • Multiplexing Images • Number of configurable images Image objects • Text objects • Graphics object Complex image objects • Status/control • dynamic objects Siemens ST 80 / ST PC · 2013 2 2/49 © Siemens AG 2013 Operator panels Mobile Panels — 170 series SIMATIC Mobile Panel 177 ■ Technical specifications (continued) 2 Lists • Number of text lists per project • Number of graphics lists per project 6AV6645-0BA01-0AX0 6AV6645-0BB01-0AX0 6AV6645-0BC01-0AX0 with integrated acknowledgment button with integrated acknowledgment button and STOP button with integrated acknowledgment button, STOP button, handwheel, keyswitch and illuminated pushbutton 300 300 300 100 100 100 0 0 0 Security • Number of user groups • Number of user rights • Password export/import 50 32 Yes 50 32 Yes 50 32 Yes Data carrier support • PC card • CF card No No No No No No Logging through printer • Recording/Printing - - - Serial, Ethernet, automatic transfer recognition Serial, Ethernet, automatic transfer recognition Serial, Ethernet, automatic transfer recognition • S7-1200 • S7-1500 S7-200, S7- 300/400, Win AC, PC (TCP/IP), SIMOTION, Modicon (Modbus), see the chapter "System interfaces" Yes Yes S7-200, S7- 300/400, Win AC, PC (TCP/IP), SIMOTION, Modicon (Modbus), see the chapter "System interfaces" Yes Yes S7-200, S7- 300/400, Win AC, PC (TCP/IP), SIMOTION, Modicon (Modbus), see the chapter "System interfaces" Yes Yes Expandability/openness • Open Platform Program Yes Yes Yes I/O I/O devices • Multi Media Card Printer Yes Printer Yes Printer Yes Mechanics/material Type of housing (front) Plastic Plastic Plastic Dimensions Housing diameter/depth (mm) Dia 245 mm / D 58 mm Dia 245 mm / D 58 mm Dia 245 mm / D 58 mm Weight Weight 1.3 kg 1.3 kg 1.3 kg Archiving • Number of archives per device Transfer (upload/download) • Transfer of configuration Process coupling • Connection to controller 2/50 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels Mobile Panels — 170 series SIMATIC Mobile Panel 177 SIMATIC Mobile Panel 177 PN (PROFINET) 1) • With integrated acknowledgement button • With integrated acknowledgement button and STOP button • With integrated acknowledgement button, STOP button, handwheel, key-operated switch and illuminated pushbutton Order No. 6AV6645-0AA01-0AX0 ■ Dimensional drawings All dimensions in mm. For installation cutout, see technical specifications. 6AV6645-0AB01-0AX0 123.9 6AV6645-0AC01-0AX0 7.80 2 6AV6645-0BA01-0AX0 121.7 6AV6645-0BB01-0AX0 245 SIMATIC Mobile Panel 177 DP (MPI/PROFIBUS) 1) • With integrated acknowledgement button • With integrated acknowledgement button and STOP button • With integrated acknowledgement button, STOP button, handwheel, key-operated switch and illuminated pushbutton 92.3 ■ Ordering data 6AV6645-0BC01-0AX0 You can find the manuals for the Mobile Panels on the Internet at: http://support.automation.siemens.com/WW/view/en/11599011/ 133300 SIMATIC HMI Manual Collection Electronic documentation on DVD, 5 languages (English, German, French, Italian and Spanish); contains: all currently available user manuals, device manuals and communication manuals for SIMATIC HMI 61.3 6AV6691-1SA01-0AX0 G_ST80_XX_00046 Documentation Mobile Panel 177, front and side view ■ More information System components for Mobile Panels Additional information is available in the Internet under: http://www.siemens.com/simatic-mobile-panels DP connection box for Mobile Panels (MPI/PROFIBUS) • Basic • Plus Note 6AV6671-5AE00-0AX0 6AV6671-5AE10-0AX0 PN connection box for Mobile Panel (PROFINET) • Basic • Plus 6AV6671-5AE01-0AX0 6AV6671-5AE11-0AX0 Connecting cable and accessories for Mobile Panels See HMI accessories, from page 2/99 1) The system components (connecting cables and connection boxes) must be ordered separately. 2) Delivery time approximately 6 weeks Do you need a specific modification or option for the products described here? Then look up "Customized products", where you will find information about additional sector-specific products that can be ordered as well as about options for customer-specific modification and adaptation. Siemens ST 80 / ST PC · 2013 2/51 © Siemens AG 2013 Operator panels Mobile Panels — 270 series SIMATIC Mobile Panel 277 ■ Overview 2 SIMATIC Mobile Panel 277 10" SIMATIC Mobile Panel 277 8" ■ Technical specifications 6AV6645-0CA01-0AX0 6AV6645-0CB01-0AX0 6AV6645-0CC01-0AX0 6AV6645-0BE02-0AX0 8" with integrated acknowledgment button 8" with integrated acknowledgment button and STOP button 8" with integrated acknowledgment button, STOP button, handwheel, keyswitch and illuminated pushbutton 10" with integrated acknowledgment button and STOP button Display Size 7.5" 7.5" 7.5" 10.4" Display type TFT, 65536 colors TFT, 65536 colors TFT, 65536 colors TFT, 65536 colors Resolution (pixels) • Resolution (WxH in pixel) 640 x 480 640 x 480 640 x 480 800 x 600 Backlighting • MTBF backlighting (at 25 °C) • MTBF backlighting (at 25 °C) about 50,000 hours 50 000 h about 50,000 hours 50 000 h about 50,000 hours 50 000 h about 50,000 hours 50 000 h Control elements Operating options Keys and Touch Keys and Touch Keys and Touch Touch Function keys, programmable 18 function keys, 18 with LEDs 18 function keys, 18 with LEDs 18 function keys, 18 with LEDs none Connection for mouse/ keyboard/barcode reader USB / USB / USB USB / USB / USB USB / USB / USB USB / USB / USB Keyboard fonts • System keys 0 Touch operation • Touch screen Analog, resistive Analog, resistive Analog, resistive Analog, resistive Special operator controls • Stop button • Acknowledgement button • Key-operated switch • Illuminated pushbutton No Yes No No Yes Yes No No Yes Yes No No • Handwheel No No Yes Yes Yes Yes; Two illuminated pushbuttons Yes 2/52 Siemens ST 80 / ST PC · 2013 No © Siemens AG 2013 Operator panels Mobile Panels — 270 series SIMATIC Mobile Panel 277 ■ Technical specifications (continued) 6AV6645-0CA01-0AX0 6AV6645-0CB01-0AX0 6AV6645-0CC01-0AX0 6AV6645-0BE02-0AX0 8" with integrated acknowledgment button 8" with integrated acknowledgment button and STOP button 8" with integrated acknowledgment button, STOP button, handwheel, keyswitch and illuminated pushbutton 10" with integrated acknowledgment button and STOP button Supply voltage Supply voltage via connection box via connection box via connection box via connection box, DC Processor Processor ARM, 520 MHz ARM, 520 MHz ARM, 520 MHz ARM, 520 Memory Type Flash / RAM Flash / RAM Flash / RAM Flash / RAM 6 MB usable memory for user data 6 MB usable memory for user data 6 MB usable memory for user data 6 MB usable memory for user data maximum buffer time 10 min maximum buffer time 10 min maximum buffer time 10 min maximum buffer time 10 min 5h 500 Hardware clock, battery backup, synchronizable Hardware clock, battery backup, synchronizable Hardware clock, battery backup, synchronizable Hardware clock, battery backup, synchronizable 1 x RS422, 1 x RS485, 1 x Ethernet (RJ45) (max. 12 Mbit/s) 1 x RS422, 1 x RS485, 1 x Ethernet (RJ45) (max. 12 Mbit/s) 1 x RS422, 1 x RS485, 1 x Ethernet (RJ45) (max. 12 Mbit/s) 1 x RS422, 1 x RS485, 1 x Ethernet (RJ45) (max. 12 Mbit/s) USB port 1 x USB 1 x USB 1 x USB 1 x USB Multi Media Card slot 1 MMC/SD card slot 1 MMC/SD card slot 1 MMC/SD card slot Usable memory for user data Battery Backup battery • Battery operation - Charging duration - Number of loading cycles, min Time of day Clock • Type Interfaces Interfaces Multimedia card/SD card slot combined Industrial Ethernet • Industrial Ethernet interface 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) Protocols PROFINET Yes Yes Yes Yes Yes Yes Yes Yes Degree and class of protection IP65 enclosure Yes Yes Yes Yes Standards, approvals, certificates Certifications CE, cULus, C-TICK, SIBE CE, cULus, C-TICK, SIBE CE, cULus, C-TICK, SIBE CE, cULus, C-TICK, SIBE Safety category according to EN954-1 (acknowledgment button, STOP button if present) 3 Safety category according to EN954-1 (acknowledgment button, STOP button if present) 3 Safety category according to EN954-1 (acknowledgment button, STOP button if present) 3 Safety category according to EN954-1 (acknowledgment button, STOP button if present) 3 d d d d Supports protocol for PROFINET IO Safety category according to EN954-1 Highest safety class achievable in safety mode • Performance Level in accordance with EN ISO 13849-1 Siemens ST 80 / ST PC · 2013 2/53 2 © Siemens AG 2013 Operator panels Mobile Panels — 270 series SIMATIC Mobile Panel 277 ■ Technical specifications (continued) 2 6AV6645-0CA01-0AX0 6AV6645-0CB01-0AX0 6AV6645-0CC01-0AX0 6AV6645-0BE02-0AX0 8" with integrated acknowledgment button 8" with integrated acknowledgment button and STOP button 8" with integrated acknowledgment button, STOP button, handwheel, keyswitch and illuminated pushbutton 10" with integrated acknowledgment button and STOP button Ambient conditions Drop height 1.2 m 1.2 m 1.2 m 1m Operating temperature • Operation 0 °C to +40 °C 0 °C to +40 °C 0 °C to +40 °C 0 °C to +40 °C Storage/transport temperature • Transport, storage -20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C Relative humidity • max. relative humidity 80 % 80 % 80 % 80 % Operating systems Operating system Windows CE Windows CE Windows CE Windows CE 16 16 16 16 Functionality under WinCC (TIA Portal) Libraries Yes Yes Yes Yes Task planner Yes Yes Yes Yes With alarm logging system (incl. buffer and acknowledgment) • Number of messages • Bit messages • Analog messages 4 000 Yes Yes 4 000 Yes Yes 4 000 Yes Yes 4 000 Yes Yes 300 500 1 000 64 KB integrated Flash, expandable 300 500 1 000 64 KB integrated Flash, expandable 300 500 1 000 64 KB integrated Flash, expandable 300 200 1 000 64 KB integrated Flash, expandable 2 048 2 048 2 048 2 048 Yes Yes Yes Yes Yes Yes Yes Yes 500 500 500 500 10,000 text elements Bit maps, icons, vector graphics 10,000 text elements Bit maps, icons, vector graphics 10,000 text elements Bit maps, icons, vector graphics 10,000 text elements Bit maps, icons, vector graphics With SIMATIC S7 Diagrams, bar graphs, sliders, analog display, invisible buttons With SIMATIC S7 Diagrams, bar graphs, sliders, analog display, invisible buttons With SIMATIC S7 Diagrams, bar graphs, sliders, analog display, invisible buttons With SIMATIC S7 Diagrams, bar graphs, sliders, analog display, invisible buttons Languages Online languages • Number of online/runtime languages Recipes • Number of recipes • Data records per recipe • Entries per data record • Recipe memory Variables • Number of variables per device • Limit values • Multiplexing Images • Number of configurable images Image objects • Text objects • Graphics object Complex image objects • Status/control • dynamic objects 2/54 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels Mobile Panels — 270 series SIMATIC Mobile Panel 277 ■ Technical specifications (continued) 6AV6645-0CA01-0AX0 6AV6645-0CB01-0AX0 6AV6645-0CC01-0AX0 6AV6645-0BE02-0AX0 8" with integrated acknowledgment button 8" with integrated acknowledgment button and STOP button 8" with integrated acknowledgment button, STOP button, handwheel, keyswitch and illuminated pushbutton 10" with integrated acknowledgment button and STOP button 500 500 500 500 400 400 400 400 20 20 20 20 20 20 20 20 10 000 10 000 10 000 10 000 50 32 Yes 50 32 Yes 50 32 Yes 50 32 Yes Alarms, report (shift report), color print, hardcopy Alarms, report (shift report), color print, hardcopy Alarms, report (shift report), color print, hardcopy Alarms, report (shift report), color print, hardcopy, PROFINET MPI/PROFIBUS DP, USB, Ethernet, automatic transfer recognition MPI/PROFIBUS DP, USB, Ethernet, automatic transfer recognition MPI/PROFIBUS DP, USB, Ethernet, automatic transfer recognition MPI/PROFIBUS DP, USB, Ethernet, automatic transfer recognition • S7-1200 • S7-1500 S5, S7-200, S7-300/400, TI 505, Win AC, PC (TCP/IP), SINUMERIK, SIMOTION, Allen Bradley (DF1), Allen Bradley (DF485), Mitsubishi (FX), OMRON (LINK/Multilink), Modicon (Modbus), further non-Siemens drivers, see chapter "System interfaces" Yes Yes S5, S7-200, S7- 300/400, TI 505, SINUMERIK, SIMOTION, Allen Bradley (DF1), Allen Bradley (DF485), Mitsubishi (FX), OMRON (LINK/Multilink), Modicon (Modbus), further non-Siemens drivers, see chapter "System interfaces" Yes Yes S5, S7-200, S7- 300/400, TI 505, SINUMERIK, SIMOTION, Allen Bradley (DF1), Allen Bradley (DF485), Mitsubishi (FX), OMRON (LINK/Multilink), Modicon (Modbus), further non-Siemens drivers, see chapter "System interfaces" Yes Yes S5, S7-200, S7- 300/400, TI 505, Win AC, SINUMERIK, SIMOTION, Allen Bradley (DF1), Allen Bradley (DF485), Mitsubishi (FX), OMRON (LINK/Multilink), Modicon (Modbus), further non-Siemens drivers, see chapter "System interfaces" Yes Yes I/O I/O devices • Multi Media Card Printer, barcode reader Yes Printer, barcode reader Yes Printer, barcode reader Yes Printer, barcode reader Yes Mechanics/material Type of housing (front) Plastic Plastic Plastic Plastic Dimensions Housing diameter/depth (mm) Dia 290 mm / D 103 mm Dia 290 mm / D 103 mm Dia 290 mm / D 103 mm Weight Weight 1.7 kg 1.7 kg 1.7 kg Lists • Number of text lists per project • Number of graphics lists per project Archiving • Number of archives per device • Number of measuring points per project • Number of entries per archive Security • Number of user groups • Number of user rights • Password export/import Logging through printer • Recording/Printing Transfer (upload/download) • Transfer of configuration Process coupling • Connection to controller 2 2.3 kg Siemens ST 80 / ST PC · 2013 2/55 © Siemens AG 2013 Operator panels Mobile Panels — 270 series SIMATIC Mobile Panel 277 ■ Ordering data SIMATIC Mobile Panel 277 10" • With integrated acknowledgement button and STOP button Order No. 6AV6645-0CA01-0AX0 ■ Dimensional drawings All dimensions in mm. For installation cutout, see technical specifications. 6AV6645-0CB01-0AX0 6AV6645-0CC01-0AX0 8° 6AV6645-0BE02-0AX0 Documentation 9 155 6AV6691-1SA01-0AX0 5 languages (English, French, German, Italian and Spanish); contains: all currently available user manuals, device manuals and communication manuals for SIMATIC HMI 103 Ø 290 129 System components for Mobile Panels DP connection box for Mobile Panels (MPI/PROFIBUS) • Basic • Plus 6AV6671-5AE00-0AX0 6AV6671-5AE10-0AX0 PN connection box for Mobile Panel (PROFINET) • Basic • Plus 6AV6671-5AE01-0AX0 6AV6671-5AE11-0AX0 Connecting cable and accessories for Mobile Panels See HMI accessories, from page 2/99 G_ST80_XX_00277 SIMATIC HMI Manual Collection Electronic documentation, on DVD 117 You can find the manuals for the Mobile Panels on the Internet at: http://support.automation.siemens.com/WW/view/en/11599011/ 133300 Mobile Panel 277 8", front and side view 1) The system components (connecting cables and connection boxes) must be ordered separately. 2) Delivery time approximately 6 weeks 320 8° 212 159 103 350 129 G_ST80_XX_00354 2 SIMATIC Mobile Panel 277 8" 1) • With integrated acknowledgement button • With integrated acknowledgement button and STOP button • With integrated acknowledgement button, STOP button, handwheel, key-operated switch and two illuminated pushbuttons Mobile Panel 277 10", front and side view ■ More information Additional information is available in the Internet under: http://www.siemens.com/simatic-mobile-panels Note Do you need a specific modification or option for the products described here? Then look up "Customized products", where you will find information about additional sector-specific products that can be ordered as well as about options for customer-specific modification and adaptation. 2/56 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels Mobile Panels — 270 series SIMATIC Mobile Panel 277(F) IWLAN ■ Overview 2 SIMATIC Mobile Panel 277(F) IWLAN ■ Technical specifications 6AV6645-0DD01-0AX1 6AV6645-0DE01-0AX1 6AV6645-0EB01-0AX1 6AV6645-0EC01-0AX1 6AV6645-0EF01-0AX1 RFID TAG with integrated handwheel, keyoperated switch and two illuminated pushbuttons with integrated acknowledgement button and emergency stop button with integrated acknowledgement button and emergency stop button, handwheel, key-operated switch, and two illuminated pushbuttons with integrated acknowledgement button and emergency stop button, handwheel, key-operated switch, and two illuminated pushbuttons Display Size 7.5" 7.5" 7.5" 7.5" 7.5" Display type TFT, 65536 colors TFT, 65536 colors TFT, 65536 colors TFT, 65536 colors TFT, 65536 colors 640 x 480 640 x 480 640 x 480 640 x 480 about 50,000 hours about 50,000 hours about 50,000 hours about 50,000 hours about 50,000 hours 50 000 h 50 000 h 50 000 h 50 000 h 50 000 h Control elements Operating options Keys and Touch Keys and Touch Keys and Touch Keys and Touch Keys and Touch Function keys, programmable 18 function keys, 18 with LEDs 18 function keys, 18 with LEDs 18 function keys, 18 with LEDs 18 function keys, 18 with LEDs 18 function keys, 18 with LEDs Connection for mouse/ keyboard/barcode reader USB / USB / USB USB / USB / USB USB / USB / USB USB / USB / USB USB / USB / USB Analog, resistive Analog, resistive Analog, resistive Analog, resistive Analog, resistive No No No No Yes Yes Yes Yes Yes Yes No No No Yes Yes Yes No No No Yes Yes Yes Yes Yes Yes Resolution (pixels) • Resolution (WxH in pixel) 640 x 480 Backlighting • MTBF backlighting (at 25 °C) • MTBF backlighting (at 25 °C) Touch operation • Touch screen Special operator controls • Stop button • Acknowledgement button • Key-operated switch • Illuminated pushbutton • Handwheel Siemens ST 80 / ST PC · 2013 2/57 © Siemens AG 2013 Operator panels Mobile Panels — 270 series SIMATIC Mobile Panel 277(F) IWLAN ■ Technical specifications (continued) 6AV6645-0DD01-0AX1 6AV6645-0DE01-0AX1 6AV6645-0EB01-0AX1 6AV6645-0EC01-0AX1 6AV6645-0EF01-0AX1 RFID TAG with integrated handwheel, keyoperated switch and two illuminated pushbuttons with integrated acknowledgement button and emergency stop button with integrated acknowledgement button and emergency stop button, handwheel, key-operated switch, and two illuminated pushbuttons with integrated acknowledgement button and emergency stop button, handwheel, key-operated switch, and two illuminated pushbuttons 2 Supply voltage Supply voltage DC DC DC DC DC Via charging station Yes Yes Yes Yes Yes Via table power supply Yes Yes Yes Yes Yes Processor Processor ARM, 520 MHz ARM, 520 MHz ARM, 520 MHz ARM, 520 MHz ARM, 520 MHz Memory Type Flash / RAM Flash / RAM Flash / RAM Flash / RAM Flash / RAM Usable memory for user data 6 MB usable memory for user data 6 MB usable memory for user data 6 MB usable memory for user data 6 MB usable memory for user data 6 MB usable memory for user data 7.2 V 5 100 mA·h 500 7.2 V 5 100 mA·h 500 7.2 V 5 100 mA·h 500 7.2 V 5 100 mA·h 500 7.2 V 5 100 mA·h 500 4h 4h Yes 4h 4h Yes 4h 4h Yes 4h 4h Yes 4h 4h Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Battery Main battery • Rated voltage • Capacity • Number of loading cycles, min • Charging time, typ. • Operating time, typ. • Display for battery capacity • Energy-saving mode • Battery replacement during operation Type of output Status LEDs LED for safe LED for communication Yes Yes Yes Yes Yes LED for battery Yes Yes Yes Yes Yes Vibrations Yes Yes Yes Yes Yes Hardware clock, battery backup, synchronizable Hardware clock, battery backup, synchronizable Hardware clock, battery backup, synchronizable Hardware clock, battery backup, synchronizable Hardware clock, battery backup, synchronizable Interfaces Interfaces 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) USB port 1 x USB 1 x USB 1 x USB 1 x USB 1 x USB Multi Media Card slot 1 MMC/SD card slot 1 MMC/SD card slot 1 MMC/SD card slot 1 MMC/SD card slot 1 MMC/SD card slot Industrial Ethernet • Industrial Ethernet interface 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) WLAN • Wireless LAN • Supports rapid roaming Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Protocols PROFINET Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Time of day Clock • Type Supports protocol for PROFINET IO Supports protocol for PROFIsafe 2/58 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels Mobile Panels — 270 series SIMATIC Mobile Panel 277(F) IWLAN ■ Technical specifications (continued) 6AV6645-0DD01-0AX1 EMC Emission of radio interference acc. to EN 55 011 • Emission of radio interferences acc. to EN 55 011 (limit class A) 6AV6645-0DE01-0AX1 6AV6645-0EB01-0AX1 6AV6645-0EC01-0AX1 6AV6645-0EF01-0AX1 RFID TAG with integrated handwheel, keyoperated switch and two illuminated pushbuttons with integrated acknowledgement button and emergency stop button with integrated acknowledgement button and emergency stop button, handwheel, key-operated switch, and two illuminated pushbuttons with integrated acknowledgement button and emergency stop button, handwheel, key-operated switch, and two illuminated pushbuttons Yes; The product is designed for use in industrial environments. When used in residential areas, the emission of radio interference according to limit class B of EN 55011 must be ensured. For further information refer to the user documentation Yes; The product is designed for use in industrial environments. When used in residential areas, the emission of radio interference according to limit class B of EN 55011 must be ensured. For further information refer to the user documentation Yes; The product is designed for use in industrial environments. When used in residential areas, the emission of radio interference according to limit class B of EN 55011 must be ensured. For further information refer to the user documentation Yes; The product is designed for use in industrial environments. When used in residential areas, the emission of radio interference according to limit class B of EN 55011 must be ensured. For further information refer to the user documentation Yes; The product is designed for use in industrial environments. When used in residential areas, the emission of radio interference according to limit class B of EN 55011 must be ensured. For further information refer to the user documentation Degree and class of protection IP65 enclosure Yes Yes Yes Yes Yes Standards, approvals, certificates Certifications CE, cULus, C-TICK CE, cULus, C-TICK CE, cULus, C-TICK CE, cULus, C-TICK CE, cULus, C-TICK TÜV safety certification Yes Yes Yes Safety category according to EN954-1 Safety category according to EN954-1 (enabling button, STOP button if present) 4 Safety category according to EN954-1 (enabling button, STOP button if present) 4 Safety category according to EN954-1 (enabling button, STOP button if present) 4 e e e Highest safety class achievable in safety mode • Performance Level in accordance with EN ISO 13849-1 Ambient conditions Drop height 1.2 m 1.2 m 1.2 m 1.2 m 1.2 m Operating temperature • Operation 0 °C to +40 °C 0 °C to +40 °C 0 °C to +40 °C 0 °C to +40 °C 0 °C to +40 °C Storage/transport temperature • Transport, storage -20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C Relative humidity • max. relative humidity 80 % 80 % 80 % 80 % 80 % Operating systems Operating system Windows CE Windows CE Windows CE Windows CE Windows CE 16 16 16 16 16 Functionality under WinCC (TIA Portal) Libraries Yes Yes Yes Yes Yes Task planner Yes Yes Yes Yes Yes With alarm logging system (incl. buffer and acknowledgment) • Number of messages • Bit messages • Analog messages 4 000 Yes Yes 4 000 Yes Yes 4 000 Yes Yes 4 000 Yes Yes 4 000 Yes Yes 300 500 1 000 64 KB integrated Flash, expandable 300 500 1 000 64 KB integrated Flash, expandable 300 500 1 000 64 KB integrated Flash, expandable 300 500 1 000 64 KB integrated Flash, expandable 300 500 1 000 64 KB integrated Flash, expandable Languages Online languages • Number of online/runtime languages Recipes • Number of recipes • Data records per recipe • Entries per data record • Recipe memory Siemens ST 80 / ST PC · 2013 2/59 2 © Siemens AG 2013 Operator panels Mobile Panels — 270 series SIMATIC Mobile Panel 277(F) IWLAN ■ Technical specifications (continued) 6AV6645-0DD01-0AX1 6AV6645-0DE01-0AX1 6AV6645-0EB01-0AX1 6AV6645-0EC01-0AX1 6AV6645-0EF01-0AX1 RFID TAG with integrated handwheel, keyoperated switch and two illuminated pushbuttons with integrated acknowledgement button and emergency stop button with integrated acknowledgement button and emergency stop button, handwheel, key-operated switch, and two illuminated pushbuttons with integrated acknowledgement button and emergency stop button, handwheel, key-operated switch, and two illuminated pushbuttons 2 048 2 048 2 048 2 048 2 048 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 500 500 500 500 500 10,000 text elements Bit maps, icons, vector graphics 10,000 text elements Bit maps, icons, vector graphics 10,000 text elements Bit maps, icons, vector graphics 10,000 text elements Bit maps, icons, vector graphics 10,000 text elements Bit maps, icons, vector graphics With SIMATIC S7 Diagrams, bar graphs, sliders, analog display, invisible buttons With SIMATIC S7 Diagrams, bar graphs, sliders, analog display, invisible buttons With SIMATIC S7 Diagrams, bar graphs, sliders, analog display, invisible buttons With SIMATIC S7 Diagrams, bar graphs, sliders, analog display, invisible buttons With SIMATIC S7 Diagrams, bar graphs, sliders, analog display, invisible buttons 500 500 500 500 500 400 400 400 400 400 20 20 20 20 20 20 20 20 20 20 10 000 10 000 10 000 10 000 10 000 50 32 Yes 50 32 Yes 50 32 Yes 50 32 Yes 50 32 Yes Alarms, report (shift report), PROFINET Alarms, report (shift report), PROFINET Alarms, report (shift report), PROFINET Alarms, report (shift report), PROFINET Alarms, report (shift report), PROFINET USB, Ethernet, automatic transfer recognition Yes USB, Ethernet, automatic transfer recognition Yes USB, Ethernet, automatic transfer recognition Yes USB, Ethernet, automatic transfer recognition Yes USB, Ethernet, automatic transfer recognition Yes 2 Variables • Number of variables per device • Limit values • Multiplexing Images • Number of configurable images Image objects • Text objects • Graphics object Complex image objects • Status/control • dynamic objects Lists • Number of text lists per project • Number of graphics lists per project Archiving • Number of archives per device • Number of measuring points per project • Number of entries per archive Security • Number of user groups • Number of user rights • Password export/import Logging through printer • Recording/Printing Transfer (upload/download) • Transfer of configuration • Wireless LAN 2/60 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels Mobile Panels — 270 series SIMATIC Mobile Panel 277(F) IWLAN ■ Technical specifications (continued) 6AV6645-0DD01-0AX1 Process coupling • Connection to controller • S7-1200 • S7-1500 • Zones - Number of zones per project, max. - Number of transponders for zones per project, max. • Effective range - Number of effective ranges per project, max. - Number of transponders for effective ranges per project, max. • Transponder - Number of transponders per project, max. - Adjustable distance range - Adjustable distance, min. - Adjustable distance, max. 6AV6645-0DE01-0AX1 6AV6645-0EB01-0AX1 6AV6645-0EC01-0AX1 6AV6645-0EF01-0AX1 RFID TAG with integrated handwheel, keyoperated switch and two illuminated pushbuttons with integrated acknowledgement button and emergency stop button with integrated acknowledgement button and emergency stop button, handwheel, key-operated switch, and two illuminated pushbuttons with integrated acknowledgement button and emergency stop button, handwheel, key-operated switch, and two illuminated pushbuttons S7-200, S7- 300/400 see section on "System interfaces" No No S7-200, S7- 300/400 see section on "System interfaces" Yes Yes Yes 254 S7-200, S7- 300/400 see section on "System interfaces" Yes Yes Yes 254 S7-200, S7- 300/400 see section on "System interfaces" No No Yes 254 S7-200, S7- 300/400 see section on "System interfaces" No No Yes 254 255 255 255 255 Yes 127 Yes 127 127 127 Yes 127 Yes 256 Yes 256 Yes 256 Yes 256 Yes Yes Yes Yes 2m 2m 2m 2m 8m 8m 8m 8m I/O I/O devices • Multi Media Card Barcode reader Yes Barcode reader Yes Barcode reader Yes Barcode reader Yes Barcode reader Yes Mechanics/material Type of housing (front) Plastic Plastic Plastic Plastic Plastic Dia 290 mm / D 103 mm Dia 290 mm / D 103 mm Dia 290 mm / D 103 mm Dia 290 mm / D 103 mm Dia 290 mm / D 103 mm 2.2 kg 2.2 kg 2.2 kg 2.2 kg Dimensions Housing diameter/depth (mm) Weight Weight 2.2 kg Siemens ST 80 / ST PC · 2013 2/61 2 © Siemens AG 2013 Operator panels Mobile Panels — 270 series SIMATIC Mobile Panel 277(F) IWLAN ■ Technical specifications (continued) 6AV6645-0FD01-0AX1 6AV6645-0FE01-0AX1 6AV6645-0GB01-0AX1 6AV6645-0GC01-0AX1 6AV6645-0GF01-0AX1 USA version USA version with handwheel, keyoperated switch and two illuminated pushbuttons USA version with integrated acknowledgement button and emergency stop button USA version with integrated acknowledgement button and emergency stop button, handwheel, key-operated switch, and two illuminated pushbuttons USA version RFID TAG with integrated acknowledgement button and emergency stop button, handwheel, key-operated switch, and two illuminated pushbuttons Display Size 7.5" 7.5" 7.5" 7.5" 7.5" Display type TFT, 65536 colors TFT, 65536 colors TFT, 65536 colors TFT, 65536 colors TFT, 65536 colors 640 x 480 640 x 480 640 x 480 640 x 480 about 50,000 hours about 50,000 hours about 50,000 hours about 50,000 hours 50 000 h 50 000 h 50 000 h 2 Resolution (pixels) • Resolution (WxH in pixel) 640 x 480 Backlighting • MTBF backlighting (at 25 °C) • MTBF backlighting (at 25 °C) about 50,000 hours 50 000 h Control elements Operating options Keys and Touch Keys and Touch Keys and Touch Keys and Touch Keys and Touch Function keys, programmable 18 function keys, 18 with LEDs 18 function keys, 18 with LEDs 18 function keys, 18 with LEDs 18 function keys, 18 with LEDs 18 function keys, 18 with LEDs Connection for mouse/ keyboard/barcode reader USB / USB / USB USB / USB / USB USB / USB / USB USB / USB / USB USB / USB / USB Analog, resistive Analog, resistive Analog, resistive Analog, resistive Analog, resistive No No No No Yes Yes Yes Yes Yes Yes No No No Yes Yes Yes No No No Yes Yes Yes Yes Yes Yes Supply voltage Supply voltage DC DC DC DC DC Via charging station Yes Yes Yes Yes Yes Via table power supply Yes Yes Yes Yes Yes Processor Processor ARM, 520 MHz ARM, 520 MHz ARM, 520 MHz ARM, 520 MHz ARM, 520 MHz Memory Type Flash / RAM Flash / RAM Flash / RAM Flash / RAM Flash / RAM Usable memory for user data 6 MB usable memory for user data 6 MB usable memory for user data 6 MB usable memory for user data 6 MB usable memory for user data 6 MB usable memory for user data 7.2 V 5 100 mA·h 500 7.2 V 5 100 mA·h 500 7.2 V 5 100 mA·h 500 7.2 V 5 100 mA·h 500 7.2 V 5 100 mA·h 500 4h 4h Yes 4h 4h Yes 4h 4h Yes 4h 4h Yes 4h 4h Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Touch operation • Touch screen Special operator controls • Stop button • Acknowledgement button • Key-operated switch • Illuminated pushbutton • Handwheel Battery Main battery • Rated voltage • Capacity • Number of loading cycles, min • Charging time, typ. • Operating time, typ. • Display for battery capacity • Energy-saving mode • Battery replacement during operation 2/62 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels Mobile Panels — 270 series SIMATIC Mobile Panel 277(F) IWLAN ■ Technical specifications (continued) Type of output Status LEDs 6AV6645-0FD01-0AX1 6AV6645-0FE01-0AX1 6AV6645-0GB01-0AX1 6AV6645-0GC01-0AX1 6AV6645-0GF01-0AX1 USA version USA version with handwheel, keyoperated switch and two illuminated pushbuttons USA version with integrated acknowledgement button and emergency stop button USA version with integrated acknowledgement button and emergency stop button, handwheel, key-operated switch, and two illuminated pushbuttons USA version RFID TAG with integrated acknowledgement button and emergency stop button, handwheel, key-operated switch, and two illuminated pushbuttons Yes Yes Yes Yes Yes Yes Yes Yes LED for safe LED for communication Yes Yes Yes Yes Yes LED for battery Yes Yes Yes Yes Yes Vibrations Yes Yes Yes Yes Yes Hardware clock, battery backup, synchronizable Hardware clock, battery backup, synchronizable Hardware clock, battery backup, synchronizable Hardware clock, battery backup, synchronizable Hardware clock, battery backup, synchronizable Interfaces Interfaces 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) USB port 1 x USB 1 x USB 1 x USB 1 x USB 1 x USB Multi Media Card slot 1 MMC/SD card slot 1 MMC/SD card slot 1 MMC/SD card slot 1 MMC/SD card slot 1 MMC/SD card slot Industrial Ethernet • Industrial Ethernet interface 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) WLAN • Wireless LAN • Supports rapid roaming Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Protocols PROFINET Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes; The product is designed for use in industrial environments. When used in residential areas, the emission of radio interference according to limit class B of EN 55011 must be ensured. For further information refer to the user documentation Yes; The product is designed for use in industrial environments. When used in residential areas, the emission of radio interference according to limit class B of EN 55011 must be ensured. For further information refer to the user documentation Yes; The product is designed for use in industrial environments. When used in residential areas, the emission of radio interference according to limit class B of EN 55011 must be ensured. For further information refer to the user documentation Time of day Clock • Type Supports protocol for PROFINET IO Supports protocol for PROFIsafe EMC Emission of radio interference acc. to EN 55 011 • Emission of radio interferences acc. to EN 55 011 (limit class A) Yes; The product is designed for use in industrial environments. When used in residential areas, the emission of radio interference according to limit class B of EN 55011 must be ensured. For further information refer to the user documentation Yes; The product is designed for use in industrial environments. When used in residential areas, the emission of radio interference according to limit class B of EN 55011 must be ensured. For further information refer to the user documentation Siemens ST 80 / ST PC · 2013 2/63 2 © Siemens AG 2013 Operator panels Mobile Panels — 270 series SIMATIC Mobile Panel 277(F) IWLAN ■ Technical specifications (continued) 6AV6645-0FD01-0AX1 6AV6645-0FE01-0AX1 6AV6645-0GB01-0AX1 6AV6645-0GC01-0AX1 6AV6645-0GF01-0AX1 USA version USA version with handwheel, keyoperated switch and two illuminated pushbuttons USA version with integrated acknowledgement button and emergency stop button USA version with integrated acknowledgement button and emergency stop button, handwheel, key-operated switch, and two illuminated pushbuttons USA version RFID TAG with integrated acknowledgement button and emergency stop button, handwheel, key-operated switch, and two illuminated pushbuttons Degree and class of protection IP65 enclosure Yes Yes Yes Yes Yes Standards, approvals, certificates Certifications CE, cULus, C-TICK CE, cULus, C-TICK 2 CE, cULus, C-TICK CE, cULus, C-TICK CE, cULus, C-TICK TÜV safety certification Yes Yes Yes Safety category according to EN954-1 Safety category according to EN954-1 (enabling button, STOP button if present) 4 Safety category according to EN954-1 (enabling button, STOP button if present) 4 Safety category according to EN954-1 (enabling button, STOP button if present) 4 e e e Highest safety class achievable in safety mode • Performance Level in accordance with EN ISO 13849-1 Ambient conditions Drop height 1.2 m 1.2 m 1.2 m 1.2 m 1.2 m Operating temperature • Operation 0 °C to +40 °C 0 °C to +40 °C 0 °C to +40 °C 0 °C to +40 °C 0 °C to +40 °C Storage/transport temperature • Transport, storage -20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C Relative humidity • max. relative humidity 80 % 80 % 80 % 80 % 80 % Operating systems Operating system Windows CE Windows CE Windows CE Windows CE Windows CE 16 16 16 16 16 Functionality under WinCC (TIA Portal) Libraries Yes Yes Yes Yes Yes Task planner Yes Yes Yes Yes Yes With alarm logging system (incl. buffer and acknowledgment) • Number of messages • Bit messages • Analog messages 4 000 Yes Yes 4 000 Yes Yes 4 000 Yes Yes 4 000 Yes Yes 4 000 Yes Yes 300 500 1 000 64 KB integrated Flash, expandable 300 500 1 000 64 KB integrated Flash, expandable 300 500 1 000 64 KB integrated Flash, expandable 300 500 1 000 64 KB integrated Flash, expandable 300 500 1 000 64 KB integrated Flash, expandable Languages Online languages • Number of online/ runtime languages Recipes • Number of recipes • Data records per recipe • Entries per data record • Recipe memory 2/64 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels Mobile Panels — 270 series SIMATIC Mobile Panel 277(F) IWLAN ■ Technical specifications (continued) Variables • Number of variables per device • Limit values • Multiplexing Images • Number of configurable images Image objects • Text objects • Graphics object Complex image objects • Status/control • dynamic objects Lists • Number of text lists per project • Number of graphics lists per project Archiving • Number of archives per device • Number of measuring points per project • Number of entries per archive Security • Number of user groups • Number of user rights • Password export/import Logging through printer • Recording/Printing Transfer (upload/download) • Transfer of configuration • Wireless LAN 6AV6645-0FD01-0AX1 6AV6645-0FE01-0AX1 6AV6645-0GB01-0AX1 6AV6645-0GC01-0AX1 6AV6645-0GF01-0AX1 USA version USA version with handwheel, keyoperated switch and two illuminated pushbuttons USA version with integrated acknowledgement button and emergency stop button USA version with integrated acknowledgement button and emergency stop button, handwheel, key-operated switch, and two illuminated pushbuttons USA version RFID TAG with integrated acknowledgement button and emergency stop button, handwheel, key-operated switch, and two illuminated pushbuttons 2 048 2 048 2 048 2 048 2 048 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 500 500 500 500 500 10,000 text elements Bit maps, icons, vector graphics 10,000 text elements Bit maps, icons, vector graphics 10,000 text elements Bit maps, icons, vector graphics 10,000 text elements Bit maps, icons, vector graphics 10,000 text elements Bit maps, icons, vector graphics With SIMATIC S7 Diagrams, bar graphs, sliders, analog display, invisible buttons With SIMATIC S7 Diagrams, bar graphs, sliders, analog display, invisible buttons With SIMATIC S7 Diagrams, bar graphs, sliders, analog display, invisible buttons With SIMATIC S7 Diagrams, bar graphs, sliders, analog display, invisible buttons With SIMATIC S7 Diagrams, bar graphs, sliders, analog display, invisible buttons 500 500 500 500 500 400 400 400 400 400 20 20 20 20 20 20 20 20 20 20 10 000 10 000 10 000 10 000 10 000 50 32 Yes 50 32 Yes 50 32 Yes 50 32 Yes 50 32 Yes Alarms, report (shift report), PROFINET Alarms, report (shift report), PROFINET Alarms, report (shift report), PROFINET Alarms, report (shift report), PROFINET Alarms, report (shift report), PROFINET USB, Ethernet, automatic transfer recognition Yes USB, Ethernet, automatic transfer recognition Yes USB, Ethernet, automatic transfer recognition Yes USB, Ethernet, automatic transfer recognition Yes USB, Ethernet, automatic transfer recognition Yes Siemens ST 80 / ST PC · 2013 2/65 2 © Siemens AG 2013 Operator panels Mobile Panels — 270 series SIMATIC Mobile Panel 277(F) IWLAN ■ Technical specifications (continued) 6AV6645-0FD01-0AX1 6AV6645-0FE01-0AX1 6AV6645-0GB01-0AX1 6AV6645-0GC01-0AX1 6AV6645-0GF01-0AX1 USA version USA version with handwheel, keyoperated switch and two illuminated pushbuttons USA version with integrated acknowledgement button and emergency stop button USA version with integrated acknowledgement button and emergency stop button, handwheel, key-operated switch, and two illuminated pushbuttons USA version RFID TAG with integrated acknowledgement button and emergency stop button, handwheel, key-operated switch, and two illuminated pushbuttons S7-200, S7- 300/400 see section on "System interfaces" Yes Yes Yes 254 S7-200, S7- 300/400 see section on "System interfaces" Yes Yes Yes 254 S7-200, S7- 300/400 see section on "System interfaces" No No Yes 254 S7-200, S7- 300/400 see section on "System interfaces" No No Yes 254 S7-200, S7- 300/400 see section on "System interfaces" No No 255 255 255 255 Yes 127 Yes 127 127 127 2 Process coupling • Connection to controller • S7-1200 • S7-1500 • Zones - Number of zones per project, max. - Number of transponders for zones per project, max. • Effective range - Number of effective ranges per project, max. - Number of transponders for effective ranges per project, max. • Transponder - Number of transponders per project, max. - Adjustable distance range - Adjustable distance, min. - Adjustable distance, max. Yes 127 Yes 256 Yes 256 Yes 256 Yes 256 Yes Yes Yes Yes 2m 2m 2m 2m 8m 8m 8m 8m I/O I/O devices • Multi Media Card Barcode reader Yes Barcode reader Yes Barcode reader Yes Barcode reader Yes Barcode reader Yes Mechanics/material Type of housing (front) Plastic Plastic Plastic Plastic Plastic Dia 290 mm / D 103 mm Dia 290 mm / D 103 mm Dia 290 mm / D 103 mm Dia 290 mm / D 103 mm Dia 290 mm / D 103 mm 2.2 kg 2.2 kg 2.2 kg 2.2 kg Dimensions Housing diameter/depth (mm) Weight Weight 2/66 Siemens ST 80 / ST PC · 2013 2.2 kg © Siemens AG 2013 Operator panels Mobile Panels — 270 series SIMATIC Mobile Panel 277(F) IWLAN ■ Ordering data SIMATIC Mobile Panel 277 IWLAN V2 (RoW version 1)) • Communication via WLAN (PROFINET) • Communication via WLAN (PROFINET) with integrated handwheel, key-operated switch and two illuminated pushbuttons SIMATIC Mobile Panel 277F IWLAN V2 PROFIsafe (RoW version 1)) • Communication via WLAN (PROFINET) with acknowledgement button and emergency stop button • Communication via WLAN (PROFINET) with acknowledgement button and emergency stop button with integrated handwheel, key-operated switch, and two illuminated pushbuttons • RFID tag version: Communication via WLAN (PROFINET) with acknowledgement button and emergency stop button with integrated handwheel, key-operated switch, and two illuminated pushbuttons SIMATIC Mobile Panel 277 IWLAN V2 (USA version) • Communication via WLAN (PROFINET) • Communication via WLAN (PROFINET) with integrated handwheel, key-operated switch and two illuminated pushbuttons SIMATIC Mobile Panel 277F IWLAN V2 PROFIsafe (USA version) • with acknowledgement button and emergency stop button • with acknowledgement button and emergency stop button with integrated handwheel, key-operated switch, and two illuminated pushbuttons • with acknowledgement button and emergency stop button with integrated handwheel, key-operated switch, and two illuminated pushbuttons (tag version) Order No. Order No. See HMI accessories, from page 2/99 Accessories 6AV6645-0DD01-0AX1 6AV6645-0DE01-0AX1 Note: Please order the table-top power supply or charging station as well. Required for charging the battery. Documentation 6AV6645-0EB01-0AX1 SIMATIC HMI Manual Collection 6AV6645-0EC01-0AX1 2 You can find the manuals for the Mobile Panels on the Internet at: http://support.automation.siemens.com/WW/view/en/11599011/ 133300 6AV6691-1SA01-0AX0 Electronic documentation on DVD, 5 languages (English, German, French, Italian and Spanish); contains: all currently available user manuals, device manuals and communication manuals for SIMATIC HMI 6AV6645-0EF01-0AX1 6AV6645-0FD01-0AX1 6AV6645-0FE01-0AX1 6AV6645-0GB01-0AX1 6AV6645-0GC01-0AX1 6AV6645-0GF01-0AX1 Starter kit SIMATIC Mobile Panel 277(F) IWLAN (RoW version1)) for • Mobile Panel 277 IWLAN V2 • Mobile Panel 277F IWLAN V2 6AV6651-5GA01-0AA1 6AV6651-5HA01-0AA1 1) RoW version: "Rest of World" version: Version for worldwide sales except in the U.S. 2) Already prepared for Rapid Roaming (iPCF-MC). iPCF-MC is already included from SCALANCE FW version V4.3.37 and higher. For national approvals see: http://www.siemens.com/wireless-approvals The Function Manuals "Fail-Safe Operation of the Mobile Panel 277F IWLAN V1" are available for downloading in English, German, and Japanese. http://support.automation.siemens.com/WW/view/en/31255853 Siemens ST 80 / ST PC · 2013 2/67 © Siemens AG 2013 Operator panels Mobile Panels — 270 series SIMATIC Mobile Panel 277(F) IWLAN ■ Dimensional drawings ■ More information All dimensions in mm. For installation cutout, see technical specifications. Additional information is available in the Internet under: http://www.siemens.com/simatic-mobile-panels Note Do you need a specific modification or addition to the products described here? Then take a look under "Customer-specific products". There, you will find information on ordering additional and standard industry products as well as possibilities for customer-specific modifications and adjustments. 8° ø 290 mm Mobile Panel 277(F) IWLAN, front and side view 2/68 Siemens ST 80 / ST PC · 2013 103 mm 129 mm G_ST80_XX_00299 155 117 9 2 © Siemens AG 2013 Operator panels System components System components for Mobile Panels ■ Overview System components for Mobile Panels are perfectly matched to the SIMATIC HMI Mobile Panels. Charging stations, transponders, and diverse connection boxes are available for various applications. Accessories for SIMATIC HMI Mobile Panels can be found under "SIMATIC HMI accessories". Only the latest SIMATIC HMI accessories are listed in this section; the full range of SIMATIC HMI accessories is available in the Mall and in our other online media. Siemens ST 80 / ST PC · 2013 2/69 2 © Siemens AG 2013 Operator panels System components Terminal boxes ■ Overview 2 ■ Technical specifications 6AV6671-5AE00-0AX0 6AV6671-5AE10-0AX0 6AV6671-5AE01-0AX0 6AV6671-5AE11-0AX0 DP connection box for Mobile Panel 177/277 (MPI/PROFIBUS) Basic DP connection box for Mobile Panel 177/277 (MPI/PROFIBUS) Plus PN connection box for Mobile Panel 177/277 (PROFINET) Basic PN connection box for Mobile Panel 177/277 (PROFINET) Plus with emergency stop circuit interruption No without emergency stop circuit interruption Yes with emergency stop circuit interruption No without emergency stop circuit interruption Yes Yes No Yes No No Yes Yes Yes No Yes Yes Yes Supply voltage Type of actuation • AC • DC DC No Yes DC No Yes DC No Yes DC No Yes Rated voltage 24 V 24 V 24 V 24 V permissible range • Supply voltage range • Supply voltage range +20.4 V to +28.8 V DC 20.4 V 28.8 V +20.4 V to +28.8 V DC 20.4 V 28.8 V +20.4 V to +28.8 V DC 20.4 V 28.8 V +20.4 V to +28.8 V DC 20.4 V 28.8 V Supply voltage 24 V DC 24 V DC 24 V DC 24 V DC Input current Rated current 0.4 A 0.5 A 0.4 A 0.5 A Power Power 10 W 12 W 10 W 12 W 1 x RS232, 1 x RS422, 1 x RS485 (max. 12 Mbit/s) 1 x RS232, 1 x RS422, 1 x RS485 (max. 12 Mbit/s) 2 x Ethernet (RJ45) 2 x Ethernet (RJ45) Number of 20 mA interfaces (TTY) 0 0 Number of RS 232 interfaces 1 1 Number of RS 422 interfaces 1 1 2 x Ethernet (RJ45) 6 2 x Ethernet (RJ45) 6 Control elements Expansions for operator control of the process • Hot swapping - without emergency stop circuit interruption - with emergency stop circuit interruption - Monitoring the STOP button - Location identifier Interfaces Interfaces Industrial Ethernet • Industrial Ethernet interface • Industrial Ethernet status LED 2/70 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels System components Terminal boxes ■ Technical specifications (continued) 6AV6671-5AE00-0AX0 6AV6671-5AE10-0AX0 6AV6671-5AE01-0AX0 6AV6671-5AE11-0AX0 DP connection box for Mobile Panel 177/277 (MPI/PROFIBUS) Basic DP connection box for Mobile Panel 177/277 (MPI/PROFIBUS) Plus PN connection box for Mobile Panel 177/277 (PROFINET) Basic PN connection box for Mobile Panel 177/277 (PROFINET) Plus IP65 IP65 IP65 IP65 IP20 housing No No No No IP54 housing No No No No IP65 enclosure Yes Yes Yes Yes NEMA 4 No No No No NEMA 4X No No No No NEMA 12 No No No No Standards, approvals, certificates Certifications CE, cULus, C-TICK CE, cULus, C-TICK CE, cULus, C-TICK CE, cULus, C-TICK CE Yes Yes Yes Yes CSA No No No No UL No No No No FM Class I Div. 2 No No No No GL No No No No ABS No No No No BV No No No No DNV No No No No LRS No No No No PRS No No No No Gost-R No No No No Use in hazardous areas • EX zone 2 • EX zone 22 No No No No No No No No 0 °C to +50 °C 0 °C to +50 °C 0 °C to +50 °C 0 °C to +50 °C 0 °C 0 °C 0 °C 0 °C 50 °C 50 °C 50 °C 50 °C -20 °C -20 °C -20 °C -20 °C 70 °C 70 °C 70 °C 70 °C -20 °C to +70 °C -20 °C to +70 °C -20 °C to +70 °C -20 °C to +70 °C 85 % 85 % 85 % 85 % Yes Yes Yes Yes 160 x 120 x 70 160 x 120 x 70 230 x 120 x 80 230 x 120 x 80 160 120 70 160 120 70 230 120 80 230 120 80 Weight Weight 0.35 kg 0.4 kg 0.45 kg 0.5 kg other free hotline Yes Yes Yes Yes Warranty period 1a 1a 1a 1a Degree and class of protection Enclosure according to EN 60529 Ambient conditions Operating temperature • Operation (vertical installation) - in vertical mounting position/ minimum - in vertical mounting position/ maximum Storage/transport temperature • Ambient temperature during storage, minimum • Ambient temperature during storage, maximal • Transport, storage Relative humidity • max. relative humidity Functionality under WinCC (TIA Portal) Applications/options • Connection point identification Dimensions External dimensions (W x H x D) in mm • Width • Height • Depth Siemens ST 80 / ST PC · 2013 2 2/71 © Siemens AG 2013 Operator panels System components Terminal boxes ■ Dimensional drawings All dimensions in mm. For installation cutout, see technical specifications. 6AV6671-5AE00-0AX0 6AV6671-5AE10-0AX0 6AV6671-5AE01-0AX0 6AV6671-5AE11-0AX0 62.7 140 G_ST80_XX_00045 11 0 120 142 ± 2 160 150 DP connection box for SIMATIC Mobile Panel 230 55 110 120 142 ± 2 220 4.5 PN connection box for SIMATIC Mobile Panel 2/72 Siemens ST 80 / ST PC · 2013 G_ST80_XX_00273 76 210 10 2 PN connection box for Mobile Panels 177/277 (PROFINET) • Basic • Plus Order No. 43 DP connection box for Mobile Panels 177/277 (MPI/PROFIBUS) • Basic • Plus 10 ■ Ordering data © Siemens AG 2013 Operator panels System components SIPLUS connection boxes ■ Overview ■ Ordering data Order No. SIPLUS connection box DP Plus for Mobile Panels 177/277 (MPI/PROFIBUS) 6AG1671-5AE10-4AX0 2 Note: SIPLUS extreme products are based on Siemens Industry standard products. The contents listed here were taken from the respective standard products. SIPLUS extreme-specific information was added. SIPLUS connection box DP Plus Order number 6AG1 671-5AE10-4AX0 Order number based on 6AV6 671-5AE10-0AX0 Ambient temperature range 0 ... +50 °C Conformal coating Coating of the printed circuit boards and the electronic components Technical data The technical data of the standard product applies except for the ambient conditions. Ambient conditions Relative humidity 100%, condensation/frost permissible. No commissioning if condensation present. Air pressure (depending on the highest positive temperature range specified) 1080 ... 795 hPa (-1000 ... +2000m) see ambient temperature range 795 ... 658 hPa (+2000 ... +3500m) derating 10 K 658 … 540 hPa (+3500 … +5000m) derating 20 K Siemens ST 80 / ST PC · 2013 2/73 © Siemens AG 2013 Operator panels System components Charging station ■ Overview ■ Ordering data Order No. Charging station for Mobile Panels 6AV6671-5CE00-0AX1 ■ Dimensional drawings All dimensions in mm. For installation cutout, see technical specifications. 85 2 160 24 V permissible range • Supply voltage range • Supply voltage range +19.2 V to +28.8 V DC 19.2 V 28.8 V Supply voltage 24 V DC Input current Rated current 3.2 A Power Power 77 W Degree and class of protection Enclosure according to EN 60529 IP65 IP65 enclosure Yes Standards, approvals, certificates Certifications CE, cULus, C-TICK CE Yes Ambient conditions Operating temperature • Operation (vertical installation) - in vertical mounting position/ minimum - in vertical mounting position/ maximum 0 °C to +40 °C 0 °C 208 Storage/transport temperature • Ambient temperature during storage, minimum • Ambient temperature during storage, maximal • Transport, storage Relative humidity • max. relative humidity Dimensions External dimensions (W x H x D) in mm • Width • Height • Depth Weight Weight 2/74 40 °C -20 °C 60 °C -20 °C to +60 °C 85 % 208 x 333 x 75 208 333 75 1.1 kg Siemens ST 80 / ST PC · 2013 72 G_ST80_XX_00297 Rated voltage 198 DC Yes 61 6AV6671-5CE00-0AX1 Supply voltage Type of actuation • DC 343 ■ Technical specifications © Siemens AG 2013 Operator panels System components Transponder ■ Overview ■ Ordering data Order No. Transponder for Mobile Panels 277 6AV6671-5CM00-0AX1 ■ Dimensional drawings All dimensions in mm. For installation cutout, see technical specifications. 45 90 2 38.5 ■ Technical specifications 6AV6671-5CM00-0AX1 Degree and class of protection Enclosure according to EN 60529 IP65 IP65 enclosure Yes Enclosure according to NEMA NEMA 4x, NEMA 12 NEMA 4X Yes NEMA 12 Yes Standards, approvals, certificates Certifications CE, cULus, C-TICK, NEMA 4x, NEMA 12 CE Yes Ambient conditions Operating temperature • Operation (vertical installation) - in vertical mounting position/ minimum - in vertical mounting position/ maximum 0 °C to +50 °C 0 °C Storage/transport temperature • Ambient temperature during storage, minimum • Ambient temperature during storage, maximal • Transport, storage Relative humidity • max. relative humidity Dimensions External dimensions (W x H x D) in mm • Width • Height • Depth Weight Weight 172 G_ST80_XX_00298 162 50 °C -20 °C 60 °C -20 °C to +60 °C 85 % 172 x 90 x 38.5 172 90 38.5 0.3 kg Siemens ST 80 / ST PC · 2013 2/75 © Siemens AG 2013 Operator panels System interfaces with WinCC (TIA Portal) System interfaces with WinCC (TIA Portal) ■ Overview 2 The SIMATIC Touch Panel (TP), Operator Panel (OP), Basic Panel, Comfort Panel, Mobile Panel, multifunctional platforms (MP)1) offer HMI functionality for the control systems: • SIMATIC S7 • Non-Siemens controllers: - Allen Bradley - Mitsubishi - Modicon - Omron For more detailed information, refer to the WinCC (TIA Portal) user manual, the "Windows-based systems communication" manual, or the WinCC (TIA Portal) online help. OPC communication and HTTP communication are offered for all Panels with an integrated Ethernet interface. Both OPC and HTTP communication can be used in parallel with the process links to SIMATIC S7 or non-Siemens PLCs. 1) Note: Interface options for HMI devices: See the individual device descriptions. OPC communication OPC Data Access is an open standard for exchanging both local and remote variables between various applications via Industrial Ethernet. The original version of OPC is based on Microsoft COM/DCOM and, therefore, requires a Microsoft Windowsbased PC operating system (not Windows CE) on both clients and servers. As OPC XML, communication is based on the Internet standard SOAP/XML and is, therefore, suitable for embedded systems with Windows CE. HTTP communication for variable exchange between SIMATIC HMI systems Communication based on HTTP message frames enables variables to be exchanged between SIMATIC HMI systems. For the sake of simplicity, SIMATIC Panel is always used in the text below. This is not restrictive, as the information is valid for all systems referred to above. If there are constraints, direct reference is made to them in the text. Communication standard SIMATIC HMI Version Comfort Panel TP 177B DP/PN OP 177B DP/PN Mobile Panel 177 PN MP 177 TP 277 OP 277 Mobile Panel 277 MP 277 MP 377 WinCC Runtime Advanced OPC Data Access V2.05a + OPC UA Data Access V1.01 + OPC Data Access XML V1.00 OPC DA Client (COM/DCOM) – – – – • OPC DA server (COM/DCOM) – – – – • OPC UA client • – – – • OPC XML DA client (SOAP/XML) – – – – • 1) OPC XML DA server (SOAP/XML) • – – • – HTTP communication for variable exchange between SIMATIC HMI systems HTTP client • • • • • HTTP server • • • • • • System interface possible – System interface not possible 1) Only through DCOM/XML gateway in scope of delivery of WinCC Advanced for access to OPC XML server of the SIMATIC Panel 2/76 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels System interfaces with WinCC (TIA Portal) SIMATIC S7 ■ Overview The following types of interface are differentiated in respect of the link between the SIMATIC Panels and SIMATIC S7 controllers: • PROFINET interface: Coupling of SIMATIC Panel to SIMATIC S7 controllers via Industrial Ethernet TCP/IP using the integrated PROFINET interface of the CPU or, alternatively, a PROFINET interface module. • MPI/PROFIBUS interface: Coupling of SIMATIC Panel to SIMATIC S7 controllers via MPI/ PROFIBUS using the integrated MPI/PROFIBUS interface of the CPU for S7-300, S7-400 or the integrated PPI interface of the CPU in the case of S7-200 or, alternatively, a PROFIBUS interface module in the case of S7-1200, S7-300 and S7-400. • PPI interface: Coupling of SIMATIC Panel to SIMATIC S7-200 via PPI network using the integrated PPI interface of the CPU PPI interface The maximum possible number of S7 connections of one CPU is determined by its performance capacity (see Catalog ST 70); from the point of view of SIMATIC Panel, the following restrictions apply: • OP 73: max. 2 connections • OP 77A, TP 177A, Basic Panel, OP 77B, TP177B, OP 177B, Mobile Panel 177: max. 4 connections • Comfort Panel, TP 277, OP 277; Mobile Panel 277, MP 177, MP 277, MP 377: max. 6 connections • PC with WinCC Runtime Advanced: max. 8 connections The original format of a master/master link has been joined by a master/slave link, which has enabled integration of the S7-200 (except CPU 212).1) The PPI interface is a point-to-point connection between a SIMATIC Panel (PPI master) or alternatively a PG (PPI master) and an S7-200 (PPI slave). The corresponding multipoint-enabled communication interfaces of SIMATIC Panels and SIMATIC S7 are used. The following are possible: • Interface between one or a number of SIMATIC Panels (MPI master) and one or a number of S7-1200/300/400s or WinAC (MPI master).(possible network topology: MPI/PROFIBUS or Industrial Ethernet, TCP/IP) • Interface between one or a number of SIMATIC Panels (MPI master) and one or a number of S7-200s (MPI slave)1) (possible network topology: PPI, MPI/PROFIBUS) Unlike PPI connections, MPI connections are static connections that are set up during booting and then monitored. In principle this type of information exchange between SIMATIC Panels and SIMATIC S7 is independent of the network used, PPI, MPI/PROFIBUS or Industrial Ethernet: SIMATIC Panels are S7 clients and SIMATIC S7 CPUs are S7 servers. 1) With regard to restricted baud transmission rates for S7-200, see Catalog ST 70. Siemens ST 80 / ST PC · 2013 2/77 2 © Siemens AG 2013 Operator panels System interfaces with WinCC (TIA Portal) SIMATIC S7 ■ Overview (continued) 2 Controller SIMATIC HMI Target hardware (PROTOCOL) (physics) OP 73 OP 77A TP 177A Basic Panel Comfort Panel OP 77B TP 177B DP OP 177B DP TP 177B DP/PN OP 177B DP/PN Mobile Panel 177 DP1) Mobile Panel 177 PN 1) TP 277 OP 277 Mobile Panel 277 1) MP 177 MP 277 MP 377 WinCC Runtime Advanced via Ethernet (TCP/IP) to max. 4 x S7-1200 – • 5) • • 5) • • via MPI or PROFIBUS network to max. 4 x S7-1200 with PROFIBUS module (DP-Master) CM 1243-5 • 3) 4) • 6) • •5) • • 7) via Ethernet (TCP/IP) to max. 4 x S7-300, -400, WinAC – • 5) • • 5) • • via MPI or PROFIBUS network to up to 4 x S7-300, S7-400, WinAC • 3) 4) • 6) • • 6) • • 7) via Ethernet (TCP/IP) (MPI protocol) to max. 4 x S7-200 – • 5) • • 5) • • via MPI or PROFIBUS network (MPI protocol) to up to 4 x S7-200 • 3) 4) • 6) • 8) • 6) 8) • 8) • 7) 8) via PPI network (MPI protocol) to up to 4 x S7-200 • 3) 4) • 6) – • 9) – – via PPI network (PPI protocol) to max. 1 x S7-200 – – • 10) • 10) • 10) • 7)10) SIMATIC S7-1200 2) SIMATIC S7-300, -400, Win AC 2) SIMATIC S7-200 2) • System interface possible – System interface not possible 1) Mobile Panel connection via special connecting cable and junction box (see Mobile Panel), see Manual for cable layout. 2) Controllers can be combined as desired 3) OP 73 can only be interfaced with max. 2 x SIMATIC S7 (MPI); network operation (parallel PG, etc.) possible 4) 5) Max. transmission rate 1.5 Mbit/s Only Basic Panel PN, TP 177B DP/PN, OP 177B DP/PN, Mobile Panel 177 PN 6) Not Basic Panel PN, Mobile Panel 177 PN 7) Connection via integrated MPI/PROFIBUS interface; use the CP 5611 A2 with a standard PC 8) Only on passive S7-200; OP 77B also on active S7-200 Only OP 77B 9) 10) Can be interfaced via PPI to max. 1 x S7-200 (PPI); network operation (parallel PG, etc) is possible 2/78 Siemens ST 80 / ST PC · 2013 Note: Detailed information regarding cable layout can be found in the online help for WinCC. © Siemens AG 2013 Operator panels System interfaces with WinCC (TIA Portal) Controllers from other manufacturers ■ Overview The SIMATIC Touch Panel (TP), Operator Panel (OP), Basic Panel, Comfort Panel, Mobile Panel, multifunctional platforms (MP) and the SIMATIC HMI software package for PC WinCC Runtime Advanced support the following protocols for the linking of control systems from other manufacturers: • Allen Bradley - Ethernet IP protocol - DF1 protocol • Mitsubishi - MC TCP/IP protocol - FX protocol • Modicon - Modbus TCP/IP protocol - Modbus RTU protocol • Omron - Link/Multi-Link protocol 2 The following table contains more detailed information. Controller SIMATIC HMI Target hardware (PROTOCOL) (physics) OP 77A TP 177A Basic Panel Comfort Panel OP 77B TP 177B DP OP 177B DP TP 177B DP/PN OP 177B DP/PN Mobile Panel 177 DP1) Mobile Panel 177 PN 1) TP 277 OP 277 Mobile Panel 277 1) MP 177 MP 277 MP 377 WinCC Runtime Advanced – • 3) • • 3) • • • 4) • 4) 5) • 4) • 4) 5) • 4) • 6) • 4) • 4) 5) • 4) • 4) 5) • 4) • 7) • 4) • 4) 5) • 4) • 4) 5) • 4) • 7) 8) • • 5) • • 5) • – • 4) • 4) 5) • 4) • 4) 5) • 4) • 7) 8) Allen Bradley (Ethernet IP) via Ethernet TCP/IP network to max. 4 x controllers 2) • ControlLogix 1756-L6x, -L6xS with Ethernet module 1756-ENBT • Guard Logix System • CompactLogix 1769-L2xE, -L3xE • CompactLogix 1769-L4x with ETHERNET module 1768-ENBT • SLC 5/05 • MicroLogix 1100, 1400 Allen Bradley (DF1) to max. 1 x controller • SLC 5/03, /04, /05 • MicroLogix (RS 232) to max. 1 x controller • PLC5/11, /20, /30, /40, /60, /80 (RS 232) via KF2 gateway and DH+ network to max. 4 x controllers 2) • SLC 5/04 • PLC5/11, /20, /30, /40, /60, /80 (RS 232) via KF2 gateway and DH+ network to max. 4 x controllers 2) • SLC 5/04 • PLC5/11, /20, /30, /40, /60, /80 (RS 422) via KF3 gateway and DH485 network to max. 4 x controllers 2) • SLC 500 • MicroLogix (RS 232) • System interface possible – System interface not possible 1) Mobile Panel connection via special connecting cable and junction box (see Mobile Panel), see Manual for cable layout. 2) The following listed controllers can be combined as required 3) Only Basic Panel PN, TP 177B DP/PN, OP 177B DP/PN, Mobile Panel 177 PN 4) For Basic Panel, Touch Panel, Operator Panel, Comfort Panel, Multi Panel, the RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is required 5) Not Basic Panel PN, Mobile Panel 177 PN Connection via Allen Bradley PC cable 1747 CP3 6) 7) 8) Note: For detailed information on cable assignment, refer to Online Help of WinCC; see also FAQs: http://support.automation.siemens.com/WW/view/en/29034071 Connection via Allen Bradley PC cable 1784 CP10 For connection to KF2/KF3 gateway, a gender-changer (25-pin socket/25-pin socket) is required on the gateway side Siemens ST 80 / ST PC · 2013 2/79 © Siemens AG 2013 Operator panels System interfaces with WinCC (TIA Portal) Controllers from other manufacturers ■ Overview (continued) 2 Controller SIMATIC HMI Target hardware (PROTOCOL) (physics) OP 77A TP 177A Basic Panel Comfort Panel OP 77B TP 177B DP OP 177B DP TP 177B DP/PN OP 177B DP/PN Mobile Panel 177 DP1) Mobile Panel 177 PN 1) TP 277 OP 277 Mobile Panel 277 1) MP 177 MP 277 MP 377 WinCC Runtime Advanced – • 3) • • 3) • • • • 4) • • 4) • • 5) Mitsubishi (MC TCP/IP) via Ethernet IP network to max. 4 x controllers 2) • FX series FX3G, FX3U, FX3UC with Ethernet module FX3U ENET, • Series Q with Ethernet module QJ71E71-100 • iQ series/QnUD QnUDEH Mitsubishi FX (serial) to max. 1 x controller FX series FX1N, FX2N (RS 232) • System interface possible – System interface not possible 1) Mobile Panel connection via special connecting cable and junction box (see Mobile Panel), see Manual for cable layout. 2) The following listed controllers can be combined as required 3) Only Basic Panel PN, TP 177B DP/PN, OP 177B DP/PN, Mobile Panel 177 PN 4) Not Basic Panel PN, Mobile Panel 177 PN 5) Connection using a Mitsubishi PC cable SC-09 with integrated level converter RS 232/RS 422 2/80 Siemens ST 80 / ST PC · 2013 Note: For detailed information on cable assignment, refer to Online Help of WinCC; see also FAQs: http://support.automation.siemens.com/WW/view/en/29034071 © Siemens AG 2013 Operator panels System interfaces with WinCC (TIA Portal) Controllers from other manufacturers ■ Overview (continued) Controller SIMATIC HMI Target hardware (PROTOCOL) (physics) OP 77A TP 177A Basic Panel Comfort Panel OP 77B TP 177B DP OP 177B DP TP 177B DP/PN OP 177B DP/PN Mobile Panel 177 DP1) Mobile Panel 177 PN 1) TP 277 OP 277 Mobile Panel 277 1) MP 177 MP 277 MP 377 WinCC Runtime Advanced 3) • • 2 Modicon (MODBUS TCP/IP) Via MODBUS TCP/IP network to max. 4 x controllers 2) • Concept Quantum, Unity Quantum • Momentum • Premium (TSX57) • TSX Micro (TSX37) • Modicon M340 20x0 (except 2010) Via TCP/IP Modbus Plus Bridge 174 CEV 200 40 and MODBUS PLUS network to max. 4 x controllers 2) • Concept Quantum, Unity Quantum • Momentum • Compact – • 3) • • – • 3) • • 3) • • • 4) • 4) 5) • 4) • 4) 5) • 4) • • 4) • 4) 5) • 4) • 4) 5) • 4) • Modicon (MODBUS RTU) to max. 1 x controller • Concept Quantum • Momentum • Compact (RS 232) Via bridge BM85-000 or PLC with bridge functionality and MODBUS PLUS network to max. 4 x controllers 2) • Concept Quantum • Compact (RS 232) • System interface possible – System interface not possible 1) Mobile Panel connection via special connecting cable and junction box (see Mobile Panel), see Manual for cable layout. 2) The following listed controllers can be combined as required 3) Only Basic Panel PN, TP 177B DP/PN, OP 177B DP/PN, Mobile Panel 177 PN 4) For Basic Panel, Touch Panel, Operator Panel, Comfort Panel, Multi Panel, the RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is required 5) Not Basic Panel PN, Mobile Panel 177 PN Note: For detailed information on cable assignment, refer to Online Help of WinCC; see also FAQs: http://support.automation.siemens.com/WW/view/en/29034071 Siemens ST 80 / ST PC · 2013 2/81 © Siemens AG 2013 Operator panels System interfaces with WinCC (TIA Portal) Controllers from other manufacturers ■ Overview (continued) 2 Controller SIMATIC HMI Target hardware (PROTOCOL) (physics) OP 77A TP 177A Basic Panel Comfort Panel OP 77B TP 177B DP OP 177B DP TP 177B DP/PN OP 177B DP/PN Mobile Panel 177 DP1) Mobile Panel 177 PN 1) TP 277 OP 277 Mobile Panel 277 1) MP 177 MP 277 MP 377 WinCC Runtime Advanced – – • 3) • 3) 4) • 3) • – – • 3) • 3) 4) • 3) • • • 4) • • 4) • 4) – – – – • 4) • 4) – Omron (Link/MultiLink) to max. 1 x controller • CP1L, CP1H, CP1E • CJ1M, CJ1H, CJ1G • CJ2H • CS1G, CS1H, CS1D • CP2MC (RS 232) via converter NT-AL001 and RS 422 network to max.4 x controllers 2) • CP1L, CP1H, CP1E • CJ1M, CJ1H, CJ1G • CJ2H • CS1G, CS1H, CS1D • CP2MC (RS 232) via RS 422 network to max. 4 x controllers 2) • CP1L, CP1H, CP1E • CJ1M, CJ1H, CJ1G (RS 422) via RS422 network to max. 4 x controllers 2) • CJ2H • CS1G, CS1H, CS1D • CP2MC (RS 422) • System interface possible – System interface not possible 1) Mobile Panel connection via special connecting cable and junction box (see Mobile Panel), see Manual for cable layout. 2) The controllers listed below can be combined in any way required; connection via RS 422 interface of the controller or via RS 422 module For Basic Panel, Touch Panel, Operator Panel, Comfort Panel, Multi Panel, the RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is required 3) 4) Not Basic Panel PN, Mobile Panel 177 PN 2/82 Siemens ST 80 / ST PC · 2013 Note: For detailed information on cable assignment, refer to Online Help of WinCC; see also FAQs: http://support.automation.siemens.com/WW/view/en/29034071 © Siemens AG 2013 Operator panels System interfaces with WinCC flexible System interfaces with WinCC flexible ■ Overview SIMATIC Basic Panel, Touch Panels (TP), Operator Panels (OP), Mobile Panel, Multifunctional Platforms (MP)1) and the SIMATIC HMI software package for PC WinCC flexible Runtime support HMI functionality in conjunction with: • SIMATIC S7 • SIMATIC S5 • SIMATIC 505 • SIMOTION • SINUMERIK 2) • Non-Siemens controllers: - Allen Bradley - DF1, DH485 and Ethernet IP protocols - GE Fanuc - SNP/SNPX protocol - LG GLOFA GM - dedicated protocol - Mitsubishi - FX and MP 4 protocols - Modicon - Modbus RTU and TCP/IP protocols - Omron I - Link/MultiLink protocol - Telemecanique - UNI-TELWAY protocol Extended functionality with WinCC flexible For more detailed information, refer to the WinCC flexible user manual, the "Windows-based systems communication" manual, and the WinCC flexible online help. HTTP communication for the variable exchange between SIMATIC HMI systems (only TP 177B DP/PN, OP 177B DP/PN, Mobile Panel 177 PN, TP 277, OP 277, Mobile Panel 277, Mobile Panel 277 IWLAN, MP 277, MP 377, WinCC flexible Runtime) 1) 2) For the sake of simplicity, SIMATIC TP/OP/MP is always used in the text below. This is not restrictive, as the information is valid for all systems referred to above. If there are constraints, direct reference is made to them in the text. Required under WinCC flexible: "SINUMERIK HMI copy license WinCC flexible CE" and "SINUMERIK HMI copy license OA". For configuring, a "SINUMERIK HMI engineering package WinCC flexible" is also necessary. WinCC flexible supports OPC communication for Multi Panel and WinCC flexible Runtime and HTTP communication for all panels with integrated Ethernet interface. Both OPC and HTTP communication can be used in parallel with the process links to SIMATIC S7/S5/505 or non-Siemens PLCs. OPC Data Access (MP 277, MP 377, WinCC flexible Runtime only) OPC Data Access is an open standard for exchanging both local and remote variables between various applications via Industrial Ethernet. The original version of OPC is based on Microsoft COM/DCOM and, therefore, requires a Microsoft Windowsbased PC operating system (not Windows CE) on both clients and servers. As OPC XML, communication is based on the Internet standard SOAP/XML and is, therefore, suitable for embedded systems with Windows CE. Options that are required: WinCC flexible/OPC server Communication based on HTTP message frames enables variables to be exchanged between SIMATIC HMI systems. Options that are required: WinCC flexible/Sm@rt Access Note Interface options for HMI devices: See the individual device descriptions. Communication standard SIMATIC HMI Version TP 177B DP/PN TP 277 Mobile Panel 277 OP 177B DP/PN Mobile Panel 177 PN OP 277 Mobile Panel 277 IWLAN 6) WinCC flexible Runtime Connection via MP 277 MP 377 MP 177 OPC Data Access V2.05a + OPC Data Access XML V1.00 OPC client (COM/DCOM) – – – • Industrial Ethernet (see Catalog IK PI) OPC server (COM/DCOM) – – – •1) Industrial Ethernet (see Catalog IK PI) OPC XML client (SOAP/XML) – – – •2) Industrial Ethernet (see Catalog IK PI) OPC XML server (SOAP/XML) – – •3) – Industrial Ethernet (see Catalog IK PI) HTTP communication for variable exchange between SIMATIC HMI systems HTTP client •4) •4) •4) •5) Industrial Ethernet (see Catalog IK PI) HTTP server •4) •4) •4) •5) Industrial Ethernet (see Catalog IK PI) • System interface possible – System interface not possible 1) Option WinCC flexible/OPC Server for WinCC flexible Runtime required 4) Option WinCC flexible/Sm@rtAccess for SIMATIC Panel required 2) Only with DCOM/XML gateway included in the scope of delivery of WinCC flexible for access to MP 277, MP 377 and MP 370 OPC XML servers Option WinCC flexible/OPC Server for SIMATIC Multi Panel required 5) Option WinCC flexible/Sm@rtAccess for WinCC flexible Runtime required Depending on the terminal box used 3) 6) Siemens ST 80 / ST PC · 2013 2/83 2 © Siemens AG 2013 Operator panels System interfaces with WinCC flexible SIMATIC S7 ■ Overview 2 The following types of interface are supported in respect of the link between SIMATIC HMI Panels and SIMATIC WinCC flexible Runtime with SIMATIC S7: • PPI interface: Interface between SIMATIC HMI Panels and SIMATIC S7-200 via PPI. Communication runs on the PPI protocol, a standard FB as with SIMATIC S5 is not required. • MPI interface: Interface between SIMATIC HMI Panels and SIMATIC S7 via the integrated PPI interface with S7-200 or MPI interface with S7-300/-400 or alternatively via the MPI interface of a separate interface module and the backplane bus to the SIMATIC S7CPU. Communication runs on the MPI protocol (PG/OP communication), a standard FB as with SIMATIC S5 is not required. • PROFIBUS interface: Interface between SIMATIC HMI Panels and SIMATIC S7 via the integrated PROFIBUS interface on the CPU or alternatively via the PROFIBUS interface on a separate interface module and the backplane bus to the SIMATIC S7-CPU. Communication runs on the MPI protocol (PG/OP communication), a standard FB as with SIMATIC S5 is not required. • PROFINET interface: Interface between SIMATIC HMI Panels and SIMATIC S7 via the integrated PROFINET interface on the CPU or alternatively via the Industrial Ethernet interface on a separate interface module and the backplane bus to the SIMATIC S7-CPU. Communication runs on the MPI protocol (PG/OP communication), a standard FB as with SIMATIC S5 is not required. The maximum possible number of S7 connections of a CPU is determined by its power (see Catalog ST 70); from the point of view of SIMATIC HMI Panels the following restrictions apply: • OP 73micro, TP 177micro: 1 connection • OP 73: max. 2 connections • OP 77A, TP 177A, Basic Panel, OP 77B, TP177B, OP 177B, Mobile Panel 177: max. 4 connections • TP 277, OP 277; Mobile Panel 277, MP 177, MP 277, MP 377: max. 6 connections • PC with WinCC flexible Runtime: max. 8 connections 2/84 Siemens ST 80 / ST PC · 2013 PPI interface From the point of view of the concept, the PPI interface is a pointto-point connection between a SIMATIC HMI Panel (PPI master) or alternatively a PG (PPI master), and an S7-200 (PPI slave). MPI interface/PROFIBUS interface/ Industrial Ethernet interface The multipoint-enabled communication interfaces of SIMATIC HMI Panels and SIMATIC S7 are used. Options are: • Interface between one or a number of SIMATIC HMI Panels (MPI master) and one or a number of S7-300/400s or WinAC (MPI master) (possible network topology: "MPI/PROFIBUS/Industrial Ethernet") • Interface between one or a number of SIMATIC HMI Panels (MPI master) and one or a number of S7-200s (MPI slave) 1) (possible network topology: "PPI/MPI/PROFIBUS") Unlike PPI connections, MPI connections are static connections that are set up during booting and then monitored. The original format of a master/master link has in the meantime been joined by a master/slave link, which has enabled integration of the S7-200 (except CPU 212). 1) In principle this type of information exchange between SIMATIC HMI Panels and SIMATIC S7 is independent of the network used, PPI, MPI, PROFIBUS or Industrial Ethernet: SIMATIC HMI Panels are S7 clients and SIMATIC S7 CPUs are S7 servers. 1) Constraints with regard to baud rate for S7-200; see Catalog ST 70. © Siemens AG 2013 Operator panels System interfaces with WinCC flexible SIMATIC S7 ■ Overview (continued) Controller SIMATIC HMI Target hardware (PROTOCOL) (physics) TD 100C OP 73micro TD 200 TD 200C TP 177micro OP 73 OP 77A Connection via TP 177A TD 400C 2 SIMATIC S7 (PPI/MPI) via PPI on S7-200 (PPI) • 1) – – – MPI cable 5) via MPI or PROFIBUS (PG/OP communication) with S7-200 – • 2) • 3) • 4) MPI cable 5) via MPI or PROFIBUS (PG/OP communication) with S7-300, -400 – – • 3) • 4) MPI cable 5) via PPI network (PPI) with max. 1 x S7-200 • 1) – – – PPI network 6) (see Catalog ST 70 and IK PI) via PPI network (PG/OP communication) with max. 4 x S7-200 • 1) • 2) • 3) • 4) PPI network 6) (see Catalog ST 70 and IK PI) via MPI or PROFIBUS network (PG/OP communication) with max. 4 x S7-200 – • 2) • 3) • 4) MPI or PROFIBUS network 6) (see Catalogs ST 70 and IK PI) via MPI or PROFIBUS network (PG/OP communication) with max. 4 x S7-300, -400, WinAC – – • 3) • 4) MPI or PROFIBUS network 6) (see Catalogs ST 70 and IK PI) via Industrial Ethernet (TCP/IP) (PG/OP communication) with max. 4 x S7-200, -300, -400, WinAC – – – – Industrial Ethernet (see Catalog IK PI) • System interface possible – System interface not possible 1) 2) TD series can only be interfaced with max. 1 x S7-200 via PPI (PPI/MPI); network operation (parallel PG, etc.) possible; max. data transfer rate 187.5 kbit/s; cable included in scope of supply OP 73micro, TP 177 micro can only be interfaced with max. 1 x S7-200 (MPI); network operation (parallel PG, etc.) possible; max. data transfer rate 187.5 kbit/s 3) OP 73 can only be interfaced with max. 2 x SIMATIC S7 (MPI); network operation (parallel PG, etc.) possible; max. data transfer rate 1.5 Mbit/s 4) 5) Max. transmission rate 1.5 Mbit/s MPI cable 6ES7 901-0BF00-0AA0 (max. 187.5 Kbit/s) included in PG scope of delivery 6) Bus connector 6GK1 500-0EA02 Siemens ST 80 / ST PC · 2013 2/85 © Siemens AG 2013 Operator panels System interfaces with WinCC flexible SIMATIC S7 ■ Overview (continued) Controller SIMATIC HMI Target hardware (PROTOCOL) (physics) Basic Panels 2 OP 77B TP 277 TP 177B DP OP 177B DP OP 277 Mobile Panel 277 TP 177B DP/PN OP 177B DP/PN Mobile Panel 277 IWLAN Mobile Panel 177 DP Mobile Panel 177 PN MP 177 MP 277 WinCC flexible Runtime Connection via MP 377 via PPI on S7-200 (PPI) – 2) • 1) 2) • 1) 2) • 1) 3) MPI cable 11) 2)5) 2) 5) 3) 5) MPI cable 11) via MPI or PROFIBUS (PG/OP communication) on S7-200 • via MPI or PROFIBUS (PG/OP communication) with S7-300, -400 • 2) • 2) • 2) • 3) MPI cable 11) via PPI network (PPI) with max. 1 x S7-200 – • 1) 2) • 1) 2) • 1) 3) PPI network 12) (see Catalog ST 70 and IK PI) via PPI network (PG/OP communication) with max. 4 x S7-200 • 2) • 6) – – PPI network 12) (see Catalog ST 70 and IK PI) via MPI or PROFIBUS network (PG/OP communication) with max. 4 x S7-200 • 2) • 2) 5) • 2) 5) • 3) 5) MPI or PROFIBUS network 12) (see Catalogs ST 70 and IK PI) via MPI or PROFIBUS network (PG/OP communication) with max. 4 x S7-300, -400, WinAC • 2) • 2) • 2) • 3) MPI or PROFIBUS network 12) (see Catalogs ST 70 and IK PI) via Industrial Ethernet (TCP/IP) (PG/OP communication) with max. 4 x S7-200, -300, -400, WinAC – 7) • 7) 8) • 8) 9) • 10) Industrial Ethernet (see Catalog IK PI) • • • • System interface possible – System interface not possible 1) Can only be interfaced with max. 1 x S7-200 via PPI (PPI); network operation (parallel PG, etc.) possible 7) Only Basic Panel PN, TP 177B DP/PN, OP 177B DP/PN, Mobile Panel 177 PN 2) Not Basic Panel PN, Mobile Panel 177 PN, Mobile Panel 277 IWLAN; 8) Mobile Panel 177 PN, Mobile Panel 277 connection via special connecting cable and junction box (see Mobile Panel); Please refer to the manual for cable assignment 9) Mobile Panel 277 IWLAN (wireless interface, see Mobile Panel) Connection via integrated Industrial Ethernet interface; use the CP 1612 with a standard PC Mobile Panel 177 DP, Mobile Panel 277 connection via special connecting cable and junction box (see Mobile Panel); Please refer to the manual for cable assignment 3) Connection via integrated MPI/PROFIBUS interface; use the CP 5611 A2 with a standard PC. 10) 4) Max. transmission rate 1.5 Mbit/s 11) 5) Only on passive S7-200; OP 77B (MPI) also on active S7-200 Only OP 77B (MPI) MPI cable 6ES7 901-0BF00-0AA0 (max. 187.5 Kbit/s) included in PG scope of delivery (for download and test purposes only) 12) Bus connector 6GK1 500-0EA02 6) 2/86 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels System interfaces with WinCC flexible SIMATIC S5 ■ Overview A variety of interfaces differing in respect of type and performance are available for linking SIMATIC HMI Panels to SIMATIC S5 (not S5-150U). However, a feature common to all is that from the point of view of the connected SIMATIC HMI Panel, the connection is always a logical point-to-point one, i.e. there is always a fixed assignment between a SIMATIC HMI Panel and a PLC. AS511 interface (not for OP 77A, TP 177A, Basic Panel, Mobile Panel 177, Mobile Panel 277) S5-90U to -135U, -155U (except CPU 922 < Version 9, except CPU 928 [6ES5 928-3UA11], except CPU 946/947 [6ES5 94•-3UA11], except CPU 946/947 [6ES5 94•-3UA21], except CPU 946/947 [6ES5 94•-3UA22] < Version 5) The AS511 interface is implemented via the PG interface of SIMATIC S5 and uses the associated CPU resources, that is, the performance capability of the SIMATIC HMI Panel is determined by the performance capability of the SIMATIC CPU used. PROFIBUS DP interface (not for OP 77A, TP 177A, Basic Panel, Mobile Panel 177 PN, Mobile Panel 277 IWLAN) S5-115U, -135U, -155U via IM 308C or CP 5431 FMS/ DP (except CPU 922 < Version 9, except CPU 928 [6ES5 928-3UA11], except CPU 946/947 [6ES5 94•-3UA11], except CPU 946/947 [6ES5 94•-3UA21], except CPU 946/947 [6ES5 94•-3UA22] < Version 5) 2 The PROFIBUS DP interface supports the connection of: • Up to 2 SIMATIC HMI Panels as SLAVES via a PROFIBUS network to a SIMATIC S5-95U with integrated PROFIBUS DP/ master interface [6ES5 095-8ME01] • Up to 30 SIMATIC HMI Panels as SLAVES via a PROFIBUS network to a SIMATIC S5 with separate PROFIBUS DP/master interface IM 308C, or CP 5431 FMS/DP Communication between SIMATIC HMI Panels (DP slaves) and SIMATIC S5 (DP master) runs via PROFIBUS DP message frames in accordance with EN 50170 with higher-level "HMI profile". A function block which must be called for each connected SIMATIC HMI Panel is required in the PLC (FB is included in scope of delivery). Siemens ST 80 / ST PC · 2013 2/87 © Siemens AG 2013 Operator panels System interfaces with WinCC flexible SIMATIC S5 ■ Overview (continued) Controller SIMATIC HMI Target hardware (PROTOCOL) OP 77A OP 77B TP 277 (physics) TP 177A Basic Panel TP 177B DP OP 177B DP OP 277 Mobile Panel 277 TP 177B DP/PN OP 177B DP/PN Mobile Panel 277 IWLAN MP 177 Mobile Panel 177 DP Mobile Panel 177 PN MP 277 MP 377 • 2) – 2 WinCC flexible Runtime Connection via • 6ES5 734-1BD201) (3.2 m) SIMATIC S5 (AS511) S5-90U to 155U except CPU 922 < version 9, – except CPU 928 (6ES5 928-3UA11) 6XV1 440-2A… (see HMI accessories/ connecting cables) except CPU 946/947 (6ES5 94.-3UA11, 6ES5 94.-3UA21, 6ES5 94.-3UA22 < version 5) (TTY) S5-90U to 155U except CPU 922 < version 9, – • 3) 5) • 3) – 6AV6 671-8XJ000AX0 except CPU 928 (6ES5 928-3UA11) (RS422-TTY adapter) except CPU 946/947 (6ES5 94.-3UA11, 6ES5 94.-3UA21, 6ES5 94.-3UA22 < version 5) (TTY) (see HMI accessories/ connecting cables) 6XV1 440-2A… SIMATIC S5 (PROFIBUS DP + HMI) via PROFIBUS DP with 1 x S5-95U/L2-DP/master (6ES5 095-8ME02) via PROFIBUS DP with IM 308C on S5-115U, -135U, -155U – •3) •3) •4) – • 3) 3) 4) – •3) PROFIBUS4) (see Catalog IK PI) • • •3) •4) PROFIBUS4) (see Catalog IK PI) except CPU 922 < version 9, except CPU 928 (6ES5 928-3UA11), except CPU 946/947 (6ES5 94.-3UA11, 6ES5 94.-3UA21, 6ES5 94.-3UA22 < version 5) via PROFIBUS DP with CP 5431 FMS/DP on S5-115U, -135U, -155U except CPU 922 < version 9, except CPU 928 (6ES5 928-3UA11), except CPU 946/947 (6ES5 94.-3UA11, 6ES5 94.-3UA21, 6ES5 94.-3UA22 < version 5) • System interface possible – System interface not possible 1) PC cable with integrated level converter RS 232/TTY 2) OP 77B only 3) WinCC flexible 2008 Service Pack 2 and higher 4) Connection via integrated MPI/PROFIBUS interface: use the CP 5611 A2 for a standard PC. 5) not for OP 77B; in this case the RS 232 interface is to be used. 2/88 Siemens ST 80 / ST PC · 2013 PROFIBUS4) (see Catalog IK PI) © Siemens AG 2013 Operator panels System interfaces with WinCC flexible SIMATIC 505 ■ Overview A variety of interfaces differing in respect of type and performance are available for linking SIMATIC HMI Panels to SIMATIC 505. PROFIBUS DP interface (not for OP 77A, TP 177A, Basic Panel, Mobile Panel 177 PN, Mobile Panel 277 IWLAN) However, a feature common to all is that from the point of view of the connected SIMATIC HMI Panel, the connection is always a logical point-to-point one, that is, there is always a fixed assignment between an HMI Panel and a PLC. SIMATIC 505 PLC or SIMATIC 545, SIMATIC 555 with CP 5434 With the PROFIBUS DP interface, up to 30 SIMATIC HMI Panels can be connected as SLAVES to one SIMATIC 545, 555 via a PROFIBUS network, with plug-in PROFIBUS DP/master interface type CP 5434. NITP interface (not for OP 77A, TP 177A, Basic Panel, Mobile Panel 177 PN, Mobile Panel 277 IWLAN) Communication between SIMATIC HMI Panels (DP slaves) and SIMATIC 505 (DP master) runs via PROFIBUS DP message frames in accordance with EN 50170 with higher-level "HMI profile". An application ladder which must be called for each connected SIMATIC HMI Panel is required in the PLC (example of application ladder included in ProTool scope of delivery). The NITP interface runs via the PG interface of the SIMATIC 505 and uses the associated CPU resources, that is, the performance capability of the SIMATIC HMI Panel is determined by the performance capability of the SIMATIC CPU used. Controller SIMATIC HMI Target hardware (PROTOCOL) (physics) OP 77A OP 77B TP 277 TP 177A TP 177B DP OP 277 Basic Panel OP 177B DP Mobile Panel 277 TP 177B DP/PN Mobile Panel 277 IWLAN OP 177B DP/PN MP 177 Mobile Panel 177 DP MP 277 Mobile Panel 177 PN MP 377 – • 1) 2) • 1) 2) PLC 545, 555 (RS 232) – 1) 2) 1) 2) PLC 535, 545/CPU 1101, 565T (RS 422) – • 1) • 1) • 4) See online help 6) PLC 545/CPU 1102, 555 (RS 422) – • 1) • 1) • 4) See online help 6) • 1) • 1) • 5) PROFIBUS 7) WinCC flexible Runtime Connection via • PPX: 2601 094-8001 3) SIMATIC 505 (NITP) PLC 525, 535, 565T (RS 232) See online help 6) • • PPX: 2601 094-8001 3) • 6XV1 440-2K… (see HMI accessories/ connecting cables) SIMATIC 505 (PROFIBUS DP + HMI) via PROFIBUS DP to 1 x PLC 545, 555 with CP 5434 – (see Catalog IK PI) • System interface possible – System interface not possible 1) Not Mobile Panel 177 PN, Mobile Panel 277 IWLAN Mobile Panel 177 DP, Mobile Panel 277 connection via special connecting cable and junction box (see Mobile Panel); see manual for cable assignment. 2) The RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is required for Touch Panels, Operator Panels, and Multi Panels 3) A standard adapter (9-/25-pin male) is required on the PLC A commercially available level converter (RS 232/RS 422) is required on the PC Connection via integrated MPI/PROFIBUS interface, use the CP 5611 A2 with a standard PC 4) 5) 6) Detailed information (cable assignment) can be found in the online help for WinCC flexible and in the Communication User Manual for Windows-based systems 7) Bus connector 6GK1 500-0EA02 Siemens ST 80 / ST PC · 2013 2/89 2 © Siemens AG 2013 Operator panels System interfaces with WinCC flexible PLCs from other manufacturers ■ Overview Allen Bradley Three communication protocols are available for the interface between SIMATIC TP/OP/MP and Allen Bradley: 2 DF1 interface (not on OP 73, Basic Panel PN, Mobile Panel 177 PN, Mobile Panel 277 IWLAN) This communication between SIMATIC TP/OP/MP and Allen Bradley runs on the basis of the DF1 protocol; the following have been tested and released: • Direct connection between a SIMATIC TP/OP/MP and the PG interface on an Allen Bradley PLC5 or the DF1 interface on an Allen Bradley SLC500 (point-to-point link) • The integration of SIMATIC TP/OP/MP via Allen Bradley KF2 gateway in an Allen Bradley DH+ network. Communication is possible between SIMATIC TP/OP/MP and up to 4 SLC 500 PLCs or PLC5s (multipoint link from the point of view of the SIMATIC TP/OP/MP; only one connection possible with TP 170A) • The integration of SIMATIC TP/OP/MP via Allen Bradley KF3 gateway in an Allen Bradley DH485 network. Communication is possible between SIMATIC TP/OP/MP and up to 4 PLCs type SLC 500 or MicroLogix (multipoint link from the point of view of the SIMATIC TP/OP/MP; only one connection possible with TP 170A) DH485 interface (not on OP 73, OP 77A, TP 177A, Basic Panel, Mobile Panel 177 PN, Mobile Panel 277 IWLAN) This communication between SIMATIC TP/OP/MP and Allen Bradley runs on the basis of the DH485 protocol; the following have been tested and released: • Direct connection between a SIMATIC TP/OP/MP and an Allen Bradley SLC500 or MicroLogix (point-to-point link) • The integration of SIMATIC TP/OP/MP via Allen Bradley AIC adapter in an Allen Bradley DH485 network. Communication is possible between SIMATIC TP/OP/MP and up to 4 PLCs type SLC 500 or MicroLogix (multipoint link from the point of view of the SIMATIC TP/OP/MP; only one connection possible with TP 170A) • The integration of SIMATIC TP/OP/MP (not PC with WinCC flexible Runtime) in an Allen Bradley DH485 network. Communication is possible between SIMATIC TP/OP/MP and up to 4 PLCs type SLC 500 or MicroLogix (multipoint link from the point of view of the SIMATIC TP/OP/MP; only one connection possible with TP 170A) Ethernet IP protocol (not on OP 73, OP 77A, TP 177A, Basic Panel, OP 77B, TP 177B DP, OP 177B DP, Mobile Panel 177 DP, Mobile Panel 277 IWLAN) This communication between SIMATIC TP/OP/MP and Allen Bradley runs based on the Ethernet IP protocol; SIMATIC TP/OP/MP integration is tested and released in an Ethernet IP network. Communication is possible between SIMATIC TP/OP/MP and up to 4 ControlLogix or CompactLogix PLCs (multipoint link from the point of view of the SIMATIC TP/OP/MP) 2/90 Siemens ST 80 / ST PC · 2013 GE-Fanuc (not on OP 73, OP 77A, TP 177A, Basic Panel, Mobile Panel 177 PN, Mobile Panel 277 IWLAN) Communication between SIMATIC TP/OP/MP and GE-Fanuc runs on the basis of the SNP protocol; the following have been tested and released: • Direct connection between a SIMATIC TP/OP/MP and a GEF 90-Micro, 90-30 or 90-70 (point-to-point link) • Integration of SIMATIC TP/OP/MP in an RS 422 network via adapter. Communication is possible between SIMATIC TP/OP/MP and up to 4 GEF 90-Micro, 90-30 or 90-70 PLCs (multipoint link from the point of view of the SIMATIC TP/OP/MP; only one connection possible with TP 170A) • The integration of SIMATIC TP/OP/MP (not PC with ProTool/ Pro Runtime or WinCC flexible Runtime) in an RS 422 network. Communication is possible between SIMATIC TP/OP/MP and up to 4 GEF 90-Micro, 90-30 or 90-70 PLCs (multipoint link from the point of view of the SIMATIC TP/OP/MP; only one connection possible with TP 170A) LG GLOFA GM (not on OP 73, OP 77A, TP 177A, Basic Panel, Mobile Panel 177 PN, Mobile Panel 277 IWLAN) Communication between SIMATIC TP/OP/MP and LG GLOFA GM runs on the basis of the dedicated protocol; the following have been tested and released: • Connection between a SIMATIC TP/OP/MP and an LG GLOFA GM with Cnet module (point-to-point link) • Integration of SIMATIC TP/OP/MP in an RS 422 network via LG Cnet module. Communication is possible between SIMATIC TP/OP/MP (not PC with ProTool/Pro Runtime) and up to 4 LG GLOFA GM PLCs on the network (multipoint link from the point of view of the SIMATIC TP/OP/MP; only one connection possible with TP 170A) Mitsubishi (not with OP 73, Basic Panel, Mobile Panel 177 PN, Mobile Panel 277 IWLAN) Two communication protocols are available for the interface between SIMATIC TP/OP/MP and Mitsubishi: FX protocol This communication between SIMATIC TP/OP/MP and Mitsubishi runs on the basis of the FX protocol; the direct connection between a SIMATIC TP/OP/MP and the PG interface of a Mitsubishi FX/FX0 (logical point-to-point link) has been tested and released. MP4 protocol This communication between SIMATIC TP/OP/MP and Mitsubishi runs on the basis of the MP4 protocol; the following have been tested and released: • Direct connection between a SIMATIC TP/OP/MP and a Mitsubishi Series FX, Series A or Series Q (point-to-point link) • Integration of SIMATIC TP/OP/MP in an RS 422 network via Mitsubishi converter FX-48SC-IF. Communication is possible between SIMATIC TP/OP/MP and up to 4 Series FX, Series A or Series Q PLCs (multipoint link from the point of view of the SIMATIC TP/OP/MP; only one connection possible with TP 170A) • The integration of SIMATIC TP/OP/MP (not PC with ProTool/ Pro Runtime or WinCC flexible Runtime) in an RS 422 network. Communication is possible between SIMATIC TP/OP/MP and up to 4 Series FX, Series A or Series Q PLCs (multipoint link from the point of view of the SIMATIC TP/OP/MP; only one connection possible with TP 170A) © Siemens AG 2013 Operator panels System interfaces with WinCC flexible PLCs from other manufacturers ■ Overview (continued) Modicon Two communication protocols are available for the interface between SIMATIC TP/OP/MP and Modicon: Omron (not with OP 73, Basic Panel PN, Mobile Panel 177 PN, Mobile Panel 277 IWLAN) Communication between SIMATIC TP/OP/MP and Modicon runs on the basis of the Modbus protocol; the following have been tested and released: • Direct connection between a SIMATIC TP/OP/MP and the Modbus interface on a Modicon 984, TSX Quantum or TSX Compact (point-to-point link) • The integration of a SIMATIC TP/OP/MP via Modicon Modbus PLUS bridge BM85-000 or the bridge function of a MODICON 984-145 or TSX Quantum into a Modbus PLUS network and communication between SIMATIC TP/OP/MP (Modbus/master) and up to 4 Modicon 984 or TSX Quantum PLCs (Modbus/slave) on the network (multipoint link from the point of view of the SIMATIC TP/OP/MP; only one connection possible with TP 170A). Communication between SIMATIC TP/OP/MP and Omron runs on the basis of the Link/MultiLink protocol; the following have been tested and released: • Direct connection between a SIMATIC TP/OP/MP and an Omron Sysmac C, Sysmac or Sysmac CV (point-to-point link) • Integration of SIMATIC TP/OP/MP in an RS 422 network via Omron converter NT-AL001. Communication is possible between SIMATIC TP/OP/MP and up to 4 Sysmac C, Sysmac or Sysmac CV PLCs (multipoint link from the point of view of the SIMATIC TP/OP/MP; only one connection possible with TP 170A) • The integration of SIMATIC TP/OP/MP (not PC with ProTool/ Pro Runtime or WinCC flexible Runtime) in an RS 422 network. Communication is possible between SIMATIC TP/OP/MP and up to 4 Sysmac C, Sysmac or Sysmac CV PLCs (multipoint link from the point of view of the SIMATIC TP/OP/MP; only one connection possible with TP 170A) Modbus TCP/IP protocol (not for OP 73, OP 77A, TP 177A, Basic Panel DP, OP77B, TP 177B DP, OP 177B DP, Mobile Panel 177 DP, Mobile Panel 277 IWLAN) Telemecanique (not on OP 73, OP 77A, TP 177A, Basic Panel, Mobile Panel 177 PN, Mobile Panel 277 IWLAN, WinCC flexible Runtime) This communication between SIMATIC TP/OP/MP and Modicon runs on the basis of the Modbus TCP/IP protocol; the following have been tested and released: • Integration of SIMATIC TP/OP/MP into a Modbus TCP/IP network. Communication is possible between SIMATIC TP/OP/MP and up to 4 Momentum, TSX Micro ( TSX 37 ), TSX Premium ( TSX 57 ), TSX Unity Premium, TSX Quantum or TSX Unity Quantum PLCs (multipoint link from the point of view of the SIMATIC TP/OP/MP) • The communication between SIMATIC TP/OP/MP via TCP/IP Modbus Plus Bridge 174 CEV 200 40 / Modbus PLUS network to Modicon 984 (except 984A, 984B, 984X ), TSX Compact, TSX Quantum or TSX Unity Quantum (multipoint link from the point of view of the SIMATIC TP/OP/MP) Data exchange between SIMATIC TP/OP/MP and Telemecanique runs on the basis of the UNI-TELWAY protocol; the following have been tested and released: • Connection between a SIMATIC TP/OP/MP (UNI-T/slave) via Telemecanique outlet TSX SCA62 and a Telemecanique TSX 17 or TSX 47/67/87/107 (UNI-T/master) (logical point-to-point link) • Connection between a SIMATIC TP/OP/MP (UNI-T/slave) via Telemecanique outlets TSX SCA62 + ACC01 and a Telemecanique TSX 37 or TSX 57 (UNI-T/master) (logical point-to-point link) • The integration of a SIMATIC TP/OP/MP via Telemecanique outlet TSX SCA62 in a UNI-TELWAY network and communication between SIMATIC TP/OP/MP (UNI-T/slave) and up to 4 TSX 17, TSX 37, TSX 57 or TSX 47/67/87/107 PLCs (UNI-T/ master or slave) on the network (multipoint link from the point of view of the SIMATIC TP/OP/MP; only one connection possible with TP 170A). Modbus protocol (not for OP 73, Basic Panel PN, Mobile Panel 177 PN, Mobile Panel 277 IWLAN) Siemens ST 80 / ST PC · 2013 2/91 2 © Siemens AG 2013 Operator panels System interfaces with WinCC flexible PLCs from other manufacturers ■ Overview (continued) Controller SIMATIC HMI Target hardware (PROTOCOL) (physics) OP 77A Basic Panel TP 177A 2 OP 77B TP 277 TP 177B DP OP 177B DP TP 177B DP/PN OP 177B DP/PN OP 277 Mobile Panel 277 / 277 IWLAN MP 177 Mobile Panel 177 DP / 177 PN MP 277 MP 377 WinCC flexible Runtime Connection via • 1747 CP3 7) Allen Bradley (DF1) • 1) 2) • 1) 2) • 1) 2) • 1) 2) • 1) 2) • 1) 2) • 1) 2) • 1) 2) • 1) • 1) • 1) • 1) – See FAQ 9) via KF2 gateway and DH+ network with up to 4 x SLC 50/04 or PLC 5/11,20,30,40,60,80 (RS 232) • 1) 2) • 1) 2) • 1) 2) • 1) 2) • 1784 CP10 7) 8) via KF2 gateway and DH+ network with up to 4 x SLC 50/04 or PLC 5/11,20,30,40,60,80 (RS 422) • 1) • 1) • 1) • 1) – See FAQ 9) via KF3 gateway and DH485 network with up to 4 x SLC 500/00,01,02,03,04,05 or MicroLogix (RS 232) • 1) 2) • 1) 2) • 1) 2) • 1) 2) • 1784 CP10 7)8) SLC 500/03,04,05 or MicroLogix (RS 232) PLC 5/11,20,30,40,60,80 (RS 232) See FAQ 9) • 1784 CP10 7) See FAQ 9) PLC 5/11,20,30,40,60,80 (RS 422) See FAQ 9) See FAQ 9) Allen Bradley (DH485) SLC 500/03,04,05 or MicroLogix (RS 232) – – • 1) 2) • 1) 2) • See FAQ 9) via AIC adapter and DH485 network with up to 4 x SLC 500 or MicroLogix (RS 232) – – • 1) 2) • 1) 2) • See FAQ 9) via DH485 network with up to 4 x SLC 500/00,01,02,03,04,05 or MicroLogix (RS 485) – – • 1) • 1) – See FAQ 9) – – • 3) 4) • 4) • See FAQ 9) Allen Bradley (Ethernet IP) via Ethernet IPnetwork with up to 4 x ControlLogix (1756-L61, 1756-L62, 1756-L63, 1756-L64, 1756-L65, each with Ethernet module 1756-ENBT) GuardLogix (1756-L61S, 1756-L62S, 1756-L61S, each with Ethernet module 1756-ENBT) or CompactLogix (1769-L32E, 1769-L35E, each with Ethernet interface onboard • System interface possible – System interface not possible 1) Not Basic Panel PN, Mobile Panel 177 PN, Mobile Panel 277 IWLAN; Mobile Panel 177 DP, Mobile Panel 277 connection via special connecting cable and junction box (see Mobile Panel); see manual for cable assignment. 2) The RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is required for Basic Panel, Touch Panel, Operator Panel, and Multi Panel 3) Only TP 177B DP/PN, OP 177B DP/PN, Mobile Panel 177 PN 4) Mobile Panel 177 PN, Mobile Panel 277 connection via special connecting cable and junction box (see Mobile Panel); see manual for cable assignment. Not Mobile Panel 277 IWLAN (wireless interface, see Mobile Panel) 5) 6) Connection via integrated Industrial Ethernet interface; use the CP 1612 with a standard PC 7) Allen Bradley PC cable Cable for connection to KF2/KF3 gateway; a gander changer (25-pin socket/25-pin socket) is required on the gateway side 8) 2/92 Siemens ST 80 / ST PC · 2013 9) Detailed information (cables used) see FAQ: http://support.automation.siemens.com/WW/view/en/29034071 in the online help for WinCC flexible and in the Communication User Manual for Windows-based systems © Siemens AG 2013 Operator panels System interfaces with WinCC flexible PLCs from other manufacturers ■ Overview (continued) Controller SIMATIC HMI Target hardware (PROTOCOL) (physics) OP 77A Basic Panel TP 177A OP 77B TP 277 TP 177B DP OP 177B DP OP 277 Mobile Panel 277 TP 177B DP/PN OP 177B DP/PN Mobile Panel 277 IWLAN Mobile Panel 177 DP Mobile Panel 177 PN MP 177 MP 277 WinCC flexible Runtime Connection via 2 MP 377 GE-Fanuc (SNP) GEF 90-Micro, 90-30, 90-70 (RS 232) – – • 1) 2) • 1) 2) • See FAQ 4) via adapter with up to 4 x GEF 90-Micro, 90-30, 90-70 (RS 232) – – • 1) 2) • 1) 2) • See FAQ 4) via adapter with up to 4 x GEF 90-Micro, 90-30, 90-70 (RS 422) – – • 1) • 1) – See FAQ 4) GLOFA-GM with Cnet module (RS 232) – – • 1) 2) • 1) 2) • See FAQ 4) With up to 4 x GLOFA-GM with Cnet module (RS 422) – – • 1) • 1) – See FAQ 4) – – – – • SC-09 6) – See FAQ 4) LG GLOFA (Dedicated) Mitsubishi FX FX0 (RS 422) FX0n, FX1n, FX2n (RS 422) – – • – – – 1) • 1) • SC-09 6) 1) – – See FAQ 4) SC-09 6) – 1) – • 1) 6) – • 1) 6) • – • Series FX with communications module • Series A (AnN, AnA, AnU, AnS) with interface module • Series Q (QnA, QnAS) with interface module (RS 232) – – • 1) 2) • 1) 2) • See FAQ 4) via FX-48SC-IF converter with up to 4 PLCs • Series FX with communications module • Series A (AnN, AnA, AnU, AnS) with interface module • Series Q (QnA, QnAS) with interface module (RS 232) – – • 1) 2) • 1) 2) • See FAQ 4) with up to 4 PLCs • Series FX with communications module • Series A (AnN, AnA, AnU, AnS) with interface module • Series Q (QnA, QnAS) with interface module (RS 422) – – • 1) • 1) – See FAQ 4) • FX1N-14MR-DS • FX1S-10MR-DS • FX2N-16MR-DS (RS 422) • – Mitsubishi (MP4) • System interface possible – System interface not possible 1) Not Mobile Panel 177 PN, Mobile Panel 277 IWLAN; Mobile Panel 177 DP, Mobile Panel 277 connection via special connecting cable and junction box (see Mobile Panel); see manual for cable assignment. 2) The RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is required for Touch Panels, Operator Panels, and Multi Panels 3) With connection using a Mitsubishi PC cable, an 15-pin/9-pin adapter 6XV1 440-2UE32 is required 4) Detailed information (cables used) see FAQ: http://support.automation.siemens.com/WW/view/de/29034071 in the online help for WinCC flexible and in the Communication User Manual for Windows-based systems 5) Mitsubishi PC cable with integrated level converter RS 232/RS 422 WinCC flexible 2008 Service Pack 2 and higher 6) Siemens ST 80 / ST PC · 2013 2/93 © Siemens AG 2013 Operator panels System interfaces with WinCC flexible PLCs from other manufacturers ■ Overview (continued) Controller SIMATIC HMI Target hardware (PROTOCOL) (physics) OP 77A Basic Panel TP 177A 2 OP 77B TP 277 TP 177B DP OP 177B DP OP 277 Mobile Panel 277 TP 177B DP/PN OP 177B DP/PN Mobile Panel 277 IWLAN Mobile Panel 177 DP Mobile Panel 177 PN MP 177 MP 277 WinCC flexible Runtime Connection via MP 377 Modicon (Modbus) 984-120, 130, 131, 141, 145, 380, 381, 185, 480, 485, 680, 685, 780, 785, or TSX-Quantum-CPU 113, 213, 424, 434, 534 (RS 232) • 1) 2) • 1) 2) • 1) 2) • 1) 2) • See FAQ 7) via bridge BM85-000 or PLC with bridge function. / Modbus PLUS network with up to 4 x 984-120, ... or TSX Quantum - CPU 113, or TSX Contact (RS 232) • 1) 2) • 1) 2) • 1) 2) • 1) 2) • See FAQ 7) TSX Compact (RS 232) • 1) 2) • 1) 2) • 1) 2) • 1) 2) • See FAQ 7) via Modbus TCP/IP network with up to 4 x TSX Unity Quantum or TSX Unity Premium or TSX Quantum or TSX Quantum with TCP/IP module 140 NOE 771 01 or TSX Unity Premium or TSX Premium with TCP/IP module TSX ETY 110 or TSX Micro with TCP/IP module TSX ETY 410 or Momentum with CPU adapter 171 CCC 980 30 – – • 3) 4) • 4) 5) • via TCP/IP ModbusPlus bridge 174 CEV 200 40 / Modbus PLUS network with up to 4 x TSX Unity Quantum or TSX Quantum or TSX Compact or 984-120, ... (except 984A, 984B, 984X ) – – • 3) 4) • 4) 5) • via Modbus TCP/IP network with up to 4 x TSX Unity Quantum or TSX Unity Premium or TSX Quantum or TSX Quantum with TCP/IP module 140NOE 771 01 or TSX Unity Premium or TSX Premium with TCP/IP module TSX ETY 110 or TSX Micro with TCP/IP module TSX ETY 410 or Momentum with CPU adapter 171 CCC 980 30 • 3) 8) • 3) 8) – – – via TCP/IP ModbusPlus Bridge 174 CEV 200 40 / Modbus PLUS network with up to 4 x TSX Unity Quantum or TSX Quantum or TSX Compact • 3) 8) • 3) 8) – – – Modicon (Modbus TCP/IP) • System interface possible – System interface not possible 1) Not Mobile Panel 177 PN, Mobile Panel 277 IWLAN; Mobile Panel 177 DP, Mobile Panel 277 connection via special connecting cable and junction box (see Mobile Panel); see manual for cable assignment. 5) 2) The RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is required for Touch Panels, Operator Panels, and Multi Panels 7) 3) Only TP 177B DP/PN, OP 177B DP/PN, Mobile Panel 177 PN 4) Mobile Panel 177 PN, Mobile Panel 277 connection via special connecting cable and junction box (see Mobile Panel); see manual for cable assignment. 2/94 Siemens ST 80 / ST PC · 2013 6) 8) Not Mobile Panel 277 IWLAN (wireless interface, see Mobile Panel) Connection via integrated Industrial Ethernet interface; use the CP 1612 with a standard PC Detailed information (cables used) see FAQ: http://support.automation.siemens.com/WW/view/en/29034071 in the online help for WinCC flexible and in the Communication User Manual for Windows-based systems WinCC flexible 2008 Service Pack 2 and higher © Siemens AG 2013 Operator panels System interfaces with WinCC flexible PLCs from other manufacturers ■ Overview (continued) Controller SIMATIC HMI Target hardware (PROTOCOL) (physics) OP 77A Basic Panel TP 177A OP 77B TP 277 TP 177B DP OP 177B DP OP 277 Mobile Panel 277 TP 177B DP/PN OP 177B DP/PN Mobile Panel 277 IWLAN Mobile Panel 177 DP Mobile Panel 177 PN MP 177 MP 277 WinCC flexible Runtime Connection via 2 MP 377 Omron (Link/MultiLink) – – • 1) 2) • 1) 2) • See FAQ 3) – – • 1) 2) • 1) 2) • See FAQ 3) – – • 1) • 1) – See FAQ 3) • 1) 4) • 1) 4) – – – via TSX SCA62 outlet with – TSX 17 or TSX 47/67/87/107 (RS 485) – • 1) • 1) – See FAQ 3) via TSX SCA62 + ACC01 outlets with TSX 37/57 (RS 485) – – • 1) • 1) – See FAQ 3) via TSX SCA62 outlet and UNI-TELWAY network with 4 x TSX 17 or TSX 37/57 (+ACC 01) or TSX 47/67/87/107 (RS 485) – – • 1) • 1) – See FAQ 3) • SYSMAC C (except CPU CQM1 – CPU 11/21) • SYSMAC Alpha • SYSMAC CV (RS 232) via NT-AL001 converter with up to 4 PLCs • SYSMAC C (except CPU CQM1 – CPU 11/21) • SYSMAC Alpha • SYSMAC CV (RS 232) with up to 4 PLCs • SYSMAC C (except CPU CQM1 – CPU 11/21) • SYSMAC Alpha • SYSMAC CV (RS 422) • CP1L-L14DT1-D • C1H-Y20DT-D • CJ1M CPU11 Telemecanique (UNI-TELWAY) • System interface possible – System interface not possible 1) 2) 3) 4) Not Mobile Panel 177 PN, Mobile Panel 277 IWLAN; Mobile Panel 177 DP, Mobile Panel 277 connection via special connecting cable and junction box (see Mobile Panel); see manual for cable assignment. The RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is required for Touch Panels, Operator Panels, and Multi Panels Detailed information (cables used) see FAQ: http://support.automation.siemens.com/WW/view/en/29034071 in the online help for WinCC flexible and in the Communication User Manual for Windows-based systems WinCC flexible 2008 Service Pack 2 and higher Siemens ST 80 / ST PC · 2013 2/95 © Siemens AG 2013 Operator panels SIMATIC HMI accessories General HMI accessories ■ Overview The specially coordinated range of accessories supplements the SIMATIC HMI core products perfectly. Industrial Hub 4 can be used, for example, to make a USB port available to the user exactly where it is required. Touch pens can be used to operate extremely small buttons, and they also ensure that the display stays clean for longer. 2 SIMATIC HMI accessories can also be used in non-Siemens devices; see the technical specifications for more detailed information. General SIMATIC HMI accessories for all currently available Panels are listed in this chapter; the full range of SIMATIC HMI accessories is available in the Mall and in our other online media. Industrial USB Hub 4 Touchscreen stylus and touch pen 2/96 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels SIMATIC HMI accessories Industrial USB Hub 4 ■ Overview • The Industrial USB Hub 4 is used as a USB port extender (4 in 1) for the connection of peripheral devices to USB 2.0 interfaces of Comfort Panels, Multi Panels, IPCs, and standard PCs. • The Industrial USB Hub 4 (IP65 degree of protection on the front, service kit may be required) can also be mounted directly in a control cabinet. • With the USB Hub 4, the USB port can be moved forwards to the control cabinet door, making it accessible without opening the cabinet door • The USB Hub 4 can also be mounted on a standard mounting rail in the control cabinet, in which case it serves as a simple interface multiplier ■ Technical specifications 6AV6671-3AH00-0AX0 6AV6671-3AH00-0AX0 Industrial USB Hub 4 Installation type/mounting Mounting rail installation possible Mounting in landscape format possible Yes; Standard - DIN rail Yes Supply voltage Type of supply voltage 24 V DC Rated voltage/DC 24 V permissible range, lower limit (DC) 20.4 V permissible range, upper limit (DC) 28.8 V Interfaces Number of USB interfaces 4; Type USB 2.0, 500 mA each; e.g. connection of mouse, keyboard, printer, USB stick, USB IPC flash drive Industrial USB Hub 4 Ambient conditions Operating temperature • Operation (vertical installation) - in vertical mounting position/ minimum - in vertical mounting position/ maximum 0 °C to +50 °C 0 °C 50 °C Storage/transport temperature • Min. • max. -20 °C 60 °C Relative humidity • max. relative humidity 90 % Mechanics/material Type of housing (front) • Plastic Yes 212 mm Degree and class of protection Type of protection 20 Dimensions Width of the housing front IP (at the front) 65 Height of housing front 156 mm Depth/installation dimension 50 mm Weight Weight without packaging 460 g Standards, approvals, certificates CE Yes Scope of supply Delivery unit in items 1; Content: 1 X USB Hub 4, 10 x plastic mounting clip, 1 x female 2-pin connector other Note: ■ Ordering data Order No. Industrial USB Hub 4 4 x USB 2.0, IP65, for control cabinet door or standard rail, for use with MP 177/MP 277/MP 377, Panel PCs, HMI IPCs and standard PCs 6AV6671-3AH00-0AX0 Service set for Industrial USB Hub 4 (incl. IP65 expansion) See HMI accessories service sets, from page 2/118 for access to the USB interface of a built-in device without having to open the control cabinet, mounting on standard rail possible, suitable for standard USB interfaces ■ More information Note for SIMATIC Panel PCs The Industrial USB Hub 4 is approved for the Windows CE/2000/ XP/Windows 7 operating systems. The appropriate drivers are supplied with the operating system software. Siemens ST 80 / ST PC · 2013 2/97 2 © Siemens AG 2013 Operator panels SIMATIC HMI accessories Touch pen and touch stylus ■ Overview If you are working with gloves, touch pens are often extremely useful when operating touch displays. They protect the display from dirt and scratching during operation and use. They are also useful for operating small buttons or input fields accurately. 2 Optional package: Touchscreen stylus and touch pen ■ Technical specifications 6AV7672-1JB00-0AA0 Touch pen, thick, resistive technology 6AV6645-7AB14-0AS0 Touch pen, thin, resistive technology Installation type/mounting Wall mounting/direct mounting possible Yes; Terminal holder can be attached Yes; using 40 cm retaining cord Standards, approvals, certificates CE Yes Yes Ambient conditions Operating temperature • Operating temperature range, max. • Operating temperature range, min. 55 °C 0 °C 55 °C 0 °C Storage/transport temperature • Min. • max. -20 °C 70 °C -20 °C 70 °C Relative humidity • max. relative humidity 90 % 90 % Mechanics/material Screw type • Torx Yes Plastic Yes Yes Dimensions Height 155 mm; Length 125 mm; Length Thickness 20 mm; Diameter 8 mm; Diameter Scope of supply Delivery unit in items 1; Optional for extension units of the PRO devices 5; Incl. retaining cord for Mobile Panel 277 10" for resistive touch screens, optimized for operating while wearing gloves for resistive touch screens other Note: ■ Ordering data Touch stylus Order No. 6AV7672-1JB00-0AA0 This catalog only includes accessories for current products. for Panels, Panel PC, Touch Monitor and other touch applications, including screw-on wall holder • 1 unit Touch pen The complete range of accessories can be found in the Mall: https://eb.automation.siemens.com 6AV6645-7AB14-0AS0 Specially designed for Mobile Panel 277 10", but also other touch displays, including attachment cord • 5 units 2/98 Note: Siemens ST 80 / ST PC · 2013 or on our SIMATIC Support pages: http://support.automation.siemens.com © Siemens AG 2013 Operator panels Mobile Panel accessories SIMATIC Mobile Panel accessories ■ Overview General Mobile Panel accessories, such as service sets and protective membranes, are listed in the respective accessories section. Special Mobile Panel accessories are listed in the following section. System components for SIMATIC HMI Mobile Panels can be found directly under the respective Mobile Panel in the products section. Mobile Panel accessories Siemens ST 80 / ST PC · 2013 2/99 2 © Siemens AG 2013 Operator panels Mobile Panel accessories Power supply unit ■ Overview The external power supply for the Mobile Panel IWLAN is intended for laboratory and office operation. Suitable SITOP power supplies are available for use with machinery and plants. 2 ■ Technical specifications 6AV6671-5CN00-0AX2 6AV6671-5CN00-0AX2 Power pack, external, Mobile Panel IWLAN Power pack, external, Mobile Panel IWLAN Supply voltage Type of supply voltage 100-240 V AC Rated voltage/DC 12 V; Output side Input current Current consumption (rated value) 1.5 A; 50-60 Hz Output current each output 5A Power Output power 60 W Interfaces HMI-side interface EMC Emission of radio interference acc. to EN 55 011 • Emission of radio interferences acc. to EN 55 011 (limit class A) Standards, approvals, certificates CE Connector 5.5 mm jack ( -) / 2.1 mm pin ( +) 12 V DC Yes; EN61000-4-2,3,4,5,6,8,11 light industry level Yes; UL69950, TÜVEN600950-1, BSMI CNS14336, CCC GB4942 approved Ambient conditions Operating temperature • Operating temperature range, max. • Operating temperature range, min. 50 °C -10 °C Storage/transport temperature • Min. • max. -20 °C 85 °C Relative humidity • max. relative humidity 90 % Vibrations • Vibration • Frequency 2 g; 10 min./1 cycle 500 Hz; 10~500 Hz Mechanics/material Type of housing (front) • Plastic Yes Dimensions Width 125 mm Height 50 mm Thickness 31.5 mm Weight Weight without packaging 305 g Scope of supply Delivery unit in items ■ Ordering data 4; AC cable for EU, US, UK and JP other Note: for Mobile Panel IWLAN Note: This catalog only includes accessories for current products. 6AV6671-5CN00-0AX2 Only suitable for operation under laboratory/office conditions. 2/100 Number of sets Order No. Accessories for Mobile Panel 277(F) IWLAN Power supply unit, external, Mobile Panel IWLAN 1; Incl. AC and DC connecting cable Siemens ST 80 / ST PC · 2013 The complete range of accessories can be found in the Mall: https://eb.automation.siemens.com or on our SIMATIC Support pages: http://support.automation.siemens.com © Siemens AG 2013 Operator panels Mobile Panel accessories Additional accessories ■ Overview ■ Technical specifications Installation type/mounting Mounting in portrait format possible 6AV6574-1AG044AA0 Wall-mounting bracket Mobile Panel Spare key Mobile Panel 2 Yes Mounting in landscape format possible No Standards, approvals, certificates CE Yes Yes 55 °C 55 °C 0 °C 0 °C Storage/transport temperature • Min. • max. -20 °C 70 °C -20 °C 70 °C Relative humidity • max. relative humidity 90 % 90 % Ambient conditions Operating temperature • Operating temperature range, max. • Operating temperature range, min. Wall-mounting bracket for Mobile Panel, front view 6AV6574-1AF044AA0 Mechanics/material Sheet steel Yes; Handle made of plastic Type of housing (front) • Sheet steel Yes; Powder-coated Dimensions Width 200 mm 35 mm Height 230 mm 18 mm Thickness Depth Weight Weight without packaging Spare keys for Mobile Panel Scope of supply Delivery unit in items other Note: 4 mm 25 mm; Constructive 550 g; 880 g incl. cable holder 30 g 1; Color: Black 10; Coupled with key ring Mobile Panel 170, Mobile Panel 177, Mobile Panel 277 IWLAN, Mobile Panel 277F IWLAN, without mounting parts For all Mobile Panels with key-operated switch Moby D data card transponder Siemens ST 80 / ST PC · 2013 2/101 © Siemens AG 2013 Operator panels Mobile Panel accessories Additional accessories ■ Ordering data 2 Order No. Wall mounting bracket for Mobile Panels metal, without mounting accessories, suitable for all Mobile Panels • 1 unit 6AV6574-1AF04-4AA0 Replacement keys for Mobile Panels metal/plastic, for all Mobile Panels, two linked by keyring • 10 units 6AV6574-1AG04-4AA0 SCALANCE SCALANCE W-788 Access Points IWLAN Access Points with built-in wireless interface; wireless networks IEEE 802.11b/g/a/h at 2.4/5 GHz to 54 Mbps; national approvals; WPA2/AES; Power over Ethernet (PoE), degree of protection IP65 (-20°C to +60°C); scope of delivery: 2 ANT795-4MR antennas, IP 67 hybrid connector, installation material, manual on CD-ROM, English/German SCALANCE W788-2RR IWLAN Dual Access Point with two built-in radio interfaces for establishment of radio connections with iPCF • National approvals for operation outside the U.S.1) 2) • National approvals for operation within the U.S. 2) SCALANCE W788-1PRO IWLAN Access Point with one built-in wireless interface • National approvals for operation outside the U.S. 1) • National approvals for operation within the U.S. Order No. SCALANCE W-786 Access Points for SIMATIC Mobile Panel 277(F) IWLAN IWLAN Access Points with integrated wireless interfaces; wireless networks; IEEE 802.11b/g/a/h at 2.4/5 GHz up to 54 Mbps. National approvals; WPA2/AES; Power over Ethernet (PoE), degree of protection IP65 (-40 °C to +70 °C); scope of delivery: Mounting hardware, 48 V DC terminal block; manual on CD-ROM; English/German SCALANCE W-786-2RR IWLAN Dual Access Point with two integrated wireless interfaces for setting up radio connections with iPCF; RJ45 connection Four internal antennas • National approvals for operation outside the U.S.1) 2) • National approvals for operation within the U.S. 2) 6GK5786-2BA60-6AB0 SCALANCE W-786-1PRO IWLAN Access Points with built-in wireless interface RJ45 connection 6GK5788-2AA60-6AA0 6GK5788-2AA60-6AB0 6GK5788-1AA60-2AA0 6GK5788-1AA60-2AB0 Two internal antennas • National approvals for operation outside the U.S. 1) • National approvals for operation within the U.S. 1) RoW version: "Rest of World" version: Version for sale worldwide, apart from in the USA. 2) Already prepared for rapid roaming (iPCF-MC); iPCF-MC is already included as of SCALANCE FW version V4.3.37. Siemens ST 80 / ST PC · 2013 6GK5786-1BA60-2AA0 6GK5786-1BA60-2AB0 SCALANCE W-784 Access Points IWLAN Access Points with built-in wireless interfaces;wireless networks IEEE 802.11b/g/a/h at 2.4/5 GHz to 54 Mbps. National approvals; WPA2/AES; Power over Ethernet (PoE), IP30 degree of protection (-20 °C to +60 °C); scope of supply: Installation material, 24 V DC terminal block; manual on CD-ROM English/German SCALANCE W784-1 IWLAN Access Points with one built-in wireless interface • National approvals for operation outside the U.S. 1) • National approvals for operation within the U.S. 2/102 6GK5786-2BA60-6AA0 6GK5784-1AA30-2AA0 6GK5784-1AA30-2AB0 © Siemens AG 2013 Operator panels Mobile Panel accessories Additional accessories Order No. ■ Dimensional drawings Further IWLAN Access Point versions SCALANCE W-786 Access Points IWLAN Access Points with integrated wireless interfaces (see Catalog IK PI); wireless networks IEEE 802.11b/g/a/h at 2.4/5 GHz up to 54 Mbps. National approvals; WPA2/AES; Power over Ethernet (PoE), degree of protection IP65 (-40°C to +70°C); scope of delivery: Installation material, 48 V DC terminal block; manual on CD-ROM; English/German; 6GK5786-... (see Catalog IK PI) SCALANCE W-788 Access Points IWLAN Access Points with integrated wireless interfaces (see Catalog IK PI); wireless networks IEEE 802.11b/g/a/h at 2.4/5 GHz up to 54 Mbps. National approvals; WPA2/AES; Power over Ethernet (PoE), degree of protection IP65 (-20°C to +60°C); scope of delivery: 2 ANT795-4MR antennas, IP67 hybrid plug-in connector, installation material, manual on CD-ROM, English/German 6GK5788-... (see Catalog IK PI) PS791-2DC power supply 24 V DC power supply for installation in SCALANCE W-786 products; operating instructions in English/ German 6GK5791-2DC00-0AA0 PS791-2AC power supply 110 V AC to 230 V AC power supply for installation in SCALANCE W-786 products; operating instructions in English/German 6GK5791-2AC00-0AA0 8° 8° 100.7 2 2 G_ST80_XX_00047 6GK5784-1AA30-... (see Catalog IK PI) 18 24.6 SCALANCE W-784 Access Points IWLAN Access Points with integrated wireless interfaces (see Catalog IK PI), wireless networks IEEE 802.11b/g/a/h at 2.4/5 GHz up to 54 Mbps. National approvals; WPA2/AES; Power over Ethernet (PoE), degree of protection IP30 (-20 °C to +60 °C); scope of delivery: Installation material, 24 V DC terminal block; manual on CD-ROM; English/German; 225.2 ■ Ordering data SIMATIC Mobile Panel wall-mounting bracket MOBY D accessories MOBY D, MDS D100 6GT2600-0AD10 • 1 unit Spacer 6GT2190-0AA00 • 1 unit Fixing pocket 6GT2190-0AB00 • 1 unit This catalog only includes accessories for current products. The complete range of accessories can be found in the Mall: https://eb.automation.siemens.com or on our SIMATIC Support pages: http://support.automation.siemens.com Siemens ST 80 / ST PC · 2013 2/103 © Siemens AG 2013 Operator panels SIMATIC HMI accessories Connectors/converters/adapters ■ Overview Components for the connection of SIMATIC HMI Panels The range comprises connectors, adapters, converters, and transducers. An adapter can be used, for example, to mechanically rotate the connector of a 9-pin panel plug by 90°. This may be beneficial in confined spaces in the control desk or installation cabinet, and is an easy way to provide additional flexibility. 2 Connectors/converters/adapters A converter can be used to simulate a connection type that is missing at the panel. In this way, for example, a TTY (20 mA) can be generated from an RS422 signal, which is required for connection to various types of PLC. Connectors are required for power supply and I/O. • 2-pin to n-pin connectors • Converters • Transducers • Adapters for changing the cable outlet direction • Bus connector SIMATIC HMI accessories can also be used on non-Siemens devices; see the technical specifications for more detailed information. General SIMATIC HMI accessories are listed in this subsection; the full range of SIMATIC HMI accessories is available in the Mall and in our other online media. 2/104 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels SIMATIC HMI Accessories HMI connecting components ■ Overview 2 RS 422 to RS 232 converter Connector, female, 16-pin, I/O RS 422 to TTY converter Connector, female, 2x2-pin, jumpered internally 90 degree angle adapter, 1:1 Connector, female, 2-pin For: • Push Button Panels • Key Panels • Text Displays • Operator Panels • Touch Panels • Multi Panels • • • • • Basic Panels Comfort Panels Mobile Panels Thin Clients Industrial USB Hub Siemens ST 80 / ST PC · 2013 2/105 © Siemens AG 2013 Operator panels SIMATIC HMI Accessories HMI connecting components ■ Technical specifications 2 6AV6671-8XA00-0AX0 6ES7193-4JB00-0AA0 Connector, female, 2-pin Connector, female, 2x2-pin Installation type/mounting Wall mounting/direct mounting possible Yes; can be plugged into SIMATIC HMI device Yes; can be plugged into SIMATIC HMI device Supply voltage Rated voltage/DC 24 V; DC 24 V; DC Interfaces Number of pins HMI-side 2; Female 2; Outgoing side jumpered internally, color-coded Number of pins device-side 2; Female, screw terminals 4; Female, spring-loaded terminals, 0.75 mm2 Standards, approvals, certificates CE Yes Yes Ambient conditions Operating temperature • Operating temperature range, max. • Operating temperature range, min. 55 °C 0 °C 55 °C 0 °C Storage/transport temperature • Min. • max. -20 °C 70 °C -20 °C 70 °C Relative humidity • max. relative humidity 95 % 95 % Mechanics/material Screw type • 4.5 V Yes Type of housing (front) • Plastic Yes Yes Dimensions Width 10 mm 10 mm Height 15 mm 22 mm Thickness 27 mm 25 mm Scope of supply Delivery unit in items 10 10 other Note: for SIMATIC HMI Panels, except for Key Panel for ET 200S, interface module, KP32F, PN-to-PN coupler 6AV6671-3XY38-4AX0 6AV6671-3XY48-4AX0 6AV6671-3XY58-4AX0 Connector, female, 12-pin Connector, female, 16-pin Connector, female, 24-pin Yes; can be plugged into SIMATIC HMI device Yes; can be plugged into SIMATIC HMI device Yes; can be plugged into SIMATIC HMI device Supply voltage Rated voltage/DC 24 V; DC 24 V; DC 24 V; DC Interfaces Number of pins HMI-side 12; Female 16; Female 24; Female Number of pins device-side 12; Female, spring-loaded terminals 16; Female, spring-loaded terminals, 0.75 mm2 24; Female, spring-loaded terminals, 0.75 mm2 Standards, approvals, certificates CE Yes Yes Yes Ambient conditions Operating temperature • Operating temperature range, max. • Operating temperature range, min. 55 °C 0 °C 55 °C 0 °C 55 °C 0 °C Storage/transport temperature • Min. • max. -20 °C 70 °C -20 °C 70 °C -20 °C 70 °C Relative humidity • max. relative humidity 95 % 95 % 95 % Mechanics/material Type of housing (front) • Plastic Yes Yes Yes Installation type/mounting Wall mounting/direct mounting possible 2/106 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels SIMATIC HMI Accessories HMI connecting components ■ Technical specifications (continued) 6AV6671-3XY38-4AX0 6AV6671-3XY48-4AX0 6AV6671-3XY58-4AX0 Connector, female, 12-pin Connector, female, 16-pin Connector, female, 24-pin Dimensions Width 16 mm 16 mm 16 mm Height 20 mm 28 mm 54 mm Thickness 20 mm 20 mm 20 mm Scope of supply Delivery unit in items 10; Without ejector 10; Without ejector 4; Without ejector other Note: for KP8 PN for KP8F PN, KP32F PN for KP32F PN 6AV6671-8XE00-0AX0 6AV6671-8XJ00-0AX0 6AV6671-8XD00-0AX0 Converter, RS 422 to RS 232 Converter RS 422 to TTY 90 degree angle adapter, 1:1 Installation type/mounting Wall mounting/direct mounting possible Yes; Can be screwed onto the HMI Yes; Can be screwed onto the HMI Yes; Can be screwed onto the HMI Interfaces Number of pins HMI-side 9; Pin (RS422) 9; Pin (RS422) 9; Male Number of pins device-side 9; Pin (RS232) 15; Socket (TTY) 9; Female Standards, approvals, certificates CE Yes Yes Yes Ambient conditions Operating temperature • Operating temperature range, max. • Operating temperature range, min. 55 °C 0 °C 55 °C 0 °C 55 °C 0 °C Storage/transport temperature • Min. • max. -20 °C 70 °C -20 °C 70 °C -20 °C 70 °C Relative humidity • max. relative humidity 95 % 95 % 95 % Mechanics/material Screw type • 4.5 V Yes; HMI page Yes; HMI page Yes; HMI page Yes Yes Type of housing (front) • Plastic • Cast light alloy 2 Yes Dimensions Width 31 mm 42 mm 31 mm Height 50 mm 62 mm 25 mm Thickness 11 mm 11 mm 25 mm Weight Weight without packaging 26 g 28 g 34 g Scope of supply Delivery unit in items 1 1 1 suitable for all SIMATIC HMI RS422 interfaces, for details refer to the operating instructions of the respective device suitable for all SIMATIC HMI RS422 interfaces, for details refer to the operating instructions of the respective device suitable for all appropriate interfaces other Note: Siemens ST 80 / ST PC · 2013 2/107 © Siemens AG 2013 Operator panels SIMATIC HMI Accessories HMI connecting components ■ Ordering data Order No. Connectors 24 V DC connector (2-pin) 2 Order No. Converters 6AV6671-8XA00-0AX0 for all SIMATIC HMI Panels, without screw mounting, loop-through not possible. Approved for all SIMATIC HMI Panels except Key Panels. 24 V DC connector (2-pin) (can be looped through) 6ES7193-4JB00-0AA0 6AV6671-3XY38-4AX0 6AV6671-8XJ00-0AX0 Adapters 90 degree angle adapter 6AV6671-3XY48-4AX0 16-pin, 24 V DC for SIMATIC HMI Key Panel KP8F PN and Key Panel KP32F PN 24-pin cable connector RS422 to TTY converter 9-pin male contact (on HMI) to 15-pin female contact, to be screwed onto HMI RS422 interface, 180 degree cable outlet, for the connection to SIMATIC S5 12-pin, 24 V DC for SIMATIC HMI Key Panel KP8 PN 16-pin cable connector 6AV6671-8XE00-0AX0 9-pin male contact (on HMI) to 9-pin male contact, to be screwed onto HMI RS422 interface, cable outlet 180 degrees, for connection of non-Siemens PLC for all SIMATIC HMI Panels, without screw mounting, loop through possible, even if connecter unplugged. Approved for Key Panels. 12-pin cable connector RS422 to RS232 converter 6AV6671-8XD00-0AX0 9-pin male contact (on HMI) to 9-pin female contact, 1:1 connection, to be screwed onto the RS485/422/232 HMI interface, or any other suitable interface 6AV6671-3XY58-4AX0 24-pin, 24 V DC for SIMATIC HMI Key Panel KP32F PN Note: Delivery units/quantities are specified in the applicable technical data. This catalog only includes accessories for current products. The complete range of accessories can be found in the Mall: https://eb.automation.siemens.com or on our SIMATIC Support pages: http://support.automation.siemens.com 2/108 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels SIMATIC HMI Accessories RS485 bus connector ■ Overview • Used for connecting PROFIBUS nodes to the PROFIBUS bus cable • Easy installation • FastConnect plugs ensure extremely short assembly times due to their insulation-displacement technology • Integrated terminating resistors (not in the case of 6ES7 972-0BA30-0XA0) • Connectors with Sub-D socket permit PG connection without the additional installation of network nodes ■ Ordering data RS485 bus connector with axial cable outlet (180°) Order No. 6GK1500-0EA02 For industrial PC, SIMATIC HMI OP, OLM; max. transmission rate 12 Mbit/s SIPLUS DP PB RS485 connector with axial cable outlet (180°) 6AG1500-0EA02-2AA0 RS485 bus connector with cable outlet (90°) 6ES7972-0BA12-0XA0 6ES7972-0BB12-0XA0 SIPLUS DP PB RS485 connector with 90° cable outlet For extended temperature range -25 … + 60 °C • without PG interface Based on 6ES7 972-0BA12-0XA0 • with PG interface Based on 6ES7 972-0BB12-0XA0 6AG1972-0BA12-2XA0 6AG1972-0BB12-2XA0 6ES7972-0BA42-0XA0 6ES7972-0BB42-0XA0 SIPLUS DP PB RS485 connector with inclined cable outlet (35°) For extended temperature range -25 … + 60 °C • without PG interface Based on 6ES7 942-0BA42-0XA0 • with PG interface Based on 6ES7 942-0BB42-0XA0 RS485 bus connector with cable outlet (30°) With screw-terminals, low-cost variant, max. transmission rate 1.5 Mbit/s With insulation displacement, max. transmission rate 12 Mbps Without PG interface • 1 unit • 100 units 6ES7972-0BA52-0XA0 6ES7972-0BA52-0XB0 With PG interface • 1 unit • 100 units 6ES7972-0BB52-0XA0 6ES7972-0BB52-0XB0 Without PG interface, grounding via control cabinet cover • 1 unit 6ES7972-0BA70-0XA0 With PG interface, grounding via control cabinet cover • 1 unit 6ES7972-0BB70-0XA0 PROFIBUS FastConnect RS485 bus connector with angled cable outlet (35°) With insulation displacement, max. transmission rate 12 Mbps • without PG interface • with PG interface RS485 bus connector with angled cable outlet (35°) With screw-terminals, max. transmission rate 12 Mbit/s • without PG interface • with PG interface PROFIBUS bus connector RS485 with FastConnect technology PROFIBUS FastConnect bus connector RS485 with 90° cable outlet For medial stress; Based-on 6GK1 500-0EA02 With screw-terminals, max. transmission rate 12 Mbit/s • without PG interface • with PG interface Order No. 6AG1972-0BA42-7XA0 6AG1972-0BB42-7XA0 6ES7972-0BA30-0XA0 PROFIBUS FastConnect bus connector RS485 Plug 180 6ES7972-0BA60-0XA0 6ES7972-0BB60-0XA0 6GK1500-0FC10 With insulation displacement terminals, with 180° cable outlet, for industrial PC, SIMATIC HMI OP, OLM; max. transmission rate 12 Mbit/s SIMATIC S5/S7 plug-in cable for PROFIBUS 6ES7901-4BD00-0XA0 Preassembled with two 9-pin sub-D connectors; max. transmission rate 12 Mbit/s; 3 m SIMATIC NET Manual Collection 6GK1975-1AA00-3AA0 Electronic manuals for communication systems, communication protocols, and communication products; on DVD; German/English Siemens ST 80 / ST PC · 2013 2/109 2 © Siemens AG 2013 Operator panels SIMATIC HMI Accessories IE FC RJ45 Plug 2 x 2 ■ Overview • Implementation of direct device connections over distances of up to 100 m with Industrial Ethernet FC installation cable 2 x 2 without patching • Easy connection (insulation displacement contacts) for 4-core Twisted Pair installation cables (100 Mbit/s) without the need for special tools • Error-preventing connection technique thanks to visible connection area as well as colored blade terminals • Industry-compatible design (rugged metal housing, no easily lost small parts) • Excellent EMC shielding and deflection (metal housing) • Integrated strain-relief for installation cables • Compatible to the EN 50173 (RJ45) / ISO IEC 11801 standard • Additional strain and bending relief of plug connector possible through latching of plug on device housing, e.g. with SCALANCE X, SCALANCE S, ET 200S. 2 ■ Ordering data Order No. IE FC RJ45 plugs Order No. IE FC TP Standard Cable GP 2 x 2 (Type A) RJ45 plug connector for Industrial Ethernet with a rugged metal housing and integrated insulation displacement contacts for connecting Industrial Ethernet FC installation cables 4-core, shielded TP installation cable for connection to IE FC Outlet RJ45/ IE FC RJ45 Plug; PROFINET-compatible; with UL approval; IE FC RJ45 Plug 180 Sold by the meter 180° cable outlet; for network components and CPs/CPUs with Industrial Ethernet interface • 1 pack = 1 unit • 1 pack = 10 units • 1 pack = 50 units max. length 1,000 m; minimum order 20 m 6GK1901-1BB10-2AA0 6GK1901-1BB10-2AB0 6GK1901-1BB10-2AE0 IE FC RJ45 Plug 90 90° cable outlet; e.g. for ET 200S • 1 pack = 1 unit • 1 pack = 10 units • 1 pack = 50 units 6GK1901-1BB20-2AA0 6GK1901-1BB20-2AB0 6GK1901-1BB20-2AE0 IE FC RJ45 Plug 145 145° cable outlet; e.g. for SIMOTION and SINAMICS • 1 pack = 1 unit • 1 pack = 10 units • 1 pack = 50 units 6GK1901-1BB30-0AA0 6GK1901-1BB30-0AB0 6GK1901-1BB30-0AE0 IE FC stripping tool 6GK1901-1GA00 Preadjusted stripping tool for fast stripping of Industrial Ethernet FC cables 2/110 Siemens ST 80 / ST PC · 2013 Preferred length • 1000 m IE FC TP Flexible Cable GP 2 x 2 (Type B) 6XV1840-2AH10 6XV1840-2AU10 6XV1870-2B 4-core, shielded TP installation cable for connection to IE FC Outlet RJ45/ IE FC RJ45 Plug for occasional movement; PROFINET-compatible; with UL approval; sold by the meter; max. length 1000 m, minimum order 20 m IE FC TP Trailing Cable GP 2 x 2 (Type C) 4-core, shielded TP installation cable for connection to IE FC Outlet RJ45/ IE FC RJ45 Plug for use in trailing cables; PROFINET-compatible; with UL approval; sold by the meter; max. length 1000 m, minimum order 20 m 6XV1870-2D © Siemens AG 2013 Operator panels SIMATIC HMI Accessories IE FC RJ45 Plug 2 x 2 ■ Ordering data IE FC TP Trailing Cable 2 x 2 (Type C) Order No. 6XV1840-3AH10 4-core, shielded TP installation cable for connection to IE FC Outlet RJ45/ IE FC RJ45 Plug 180/90 for use in trailing cables; PROFINET-compatible; without UL approval; sold by the meter; max. length 1000 m, minimum order 20 m IE TP Torsion Cable GP 2 x 2 (Type C) 6XV1870-2F 6XV1840-4AH10 IE FC TP Food Cable GP 2 x 2 (Type C) 2 6XV1871-2L 4-core, shielded TP installation cable for connection to IE FC Outlet RJ45/ IE FC RJ45 Plug 180/90 for the food and beverages industry; PROFINET-compliant; sold by the meter; max. length 1000 m, minimum order 20 m IE FC Blade Cassettes (5 mm) 6GK1901-1GB01 Replacement blade cassette for the Industrial Ethernet stripping tool; for use with IE FC RJ45 Plugs and Modular Outlet, 5 items 4-core, shielded TP installation cable for connection to IE FC Outlet RJ45/ IE FC RJ45 Plug 180/90; marine approval; sold by the meter; max. length 1000 m, minimum order 20 m IE FC TP FRNC Cable GP 2 x 2 (Type B) 6XV1871-2S 4-core, shielded TP installation cable for connection to IE FC Outlet RJ45/ IE FC RJ45 Plug 180/90 for use in festoon applications; PROFINET-compatible; with UL approval; sold by the meter; max. length 1000 m, minimum order 20 m 4-core, shielded TP installation cable for connection to IE FC Outlet RJ45/ IE FC RJ45 Plug for use with robots; PROFINETcompatible; with UL approval; sold by the meter; max. length 1000 m, minimum order 20 m IE FC TP Marine Cable 2 x 2 (Type B) Order No. IE FC TP Festoon Cable GP 2 x 2 (Type B) 6XV1871-2F 4-core, shielded, halogen-free TP installation cable for connection to IE FC Outlet RJ45/ IE FC RJ45 Plug for occasional movement; PROFINET-compatible; with UL approval; sold by the meter; max. length 1000 m, minimum order 20 m Siemens ST 80 / ST PC · 2013 2/111 © Siemens AG 2013 Operator panels SIMATIC HMI Accessories Connecting cables ■ Overview 2 Example - connecting cables Connecting cable PN (PROFINET) for Mobile Panels Key P = PROCESS COUPLING K = optional process coupling (option required) D = DOWNLOAD (update operating system, project, …) U = booting (factory setting in the case of a missing or damaged operating system) MBP = Mobile Panel You can find order numbers for the connecting cables required to link SIMATIC Panels under ordering data. Connecting cable DP (PROFIBUS) for Mobile Panels 2/112 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels SIMATIC HMI Accessories Connecting cables ■ Overview (continued) Overview of SIMATIC HMI connection options RS 232 external (15/9-pole) TD-PPI (incl. voltage) RS 232 Null modem RS 232/PPI multi-master cable USB/PPI multi-master cable MPI (PG-S7) up to 187.5 kbaud 6XV1 440-2Kxxx 6ES7 9013EB10-0XA0 6ES7 9011BF00-0XA0 6ES7 9013CB30-0XA0 6ES7 9013DB30-0XA0 6ES7 9010BF00-0AA0 Key Panel KP8/KP8F, KP32F - - - - - - PP7, PP17-I, PP17-II - - - - - - KTP400 Basic mono PN - - - - - - KTP600 Basic mono PN - - - - - - KTP600 Basic color DP - - - D/U D/U P/D KTP600 Basic color PN - - - - - - KTP1000 Basic color DP - - - D/U D/U P/D KTP1000 Basic color PN - - - - - - KTP1500 Basic color PN - - - - - - K(T)P400 Comfort - - - - - P/D K(T)P700 - KP1500 Comfort - - - - - P/D TP700 -TP2200 Comfort - - - - - P/D MBP 177 - - - D/U - - MBP 277 - - - D/U - - TD200 - P - D/U - P TD400C - P - D/U - P OP73micro - P - D/U D/U P TP177micro - - - D/U D/U - OP73 - P - D/U D/U P/D OP77A - - - D/U D/U P/D OP77B P - D/U - - P/D TP177A - - - D/U D/U P/D TP177B P 1) - - D/U - P/D TP177B 4" P 1) - D D - P/D OP177B P 1) - - D/U - P/D TP277-6 P 1) - - D/U - P/D OP277-6 P 1) - - D/U - P/D MP177-6 T P 1) - - D/U - P/D MP277-8 T P 1) - - D/U - P/D MP277-10 T P 1) - - D/U - P/D MP377-12 T P 1) - - D - P/D MP377-15 T P 1) - - D - P/D MP377-19 T P 1) - - D - P/D 1) 2 Only in conjunction with the RS 422/232 converter Siemens ST 80 / ST PC · 2013 2/113 © Siemens AG 2013 Operator panels SIMATIC HMI Accessories Connecting cables ■ Overview (continued) DP PtP 6XV1 8300Axxx 2 DP Standard DP (Mobile Panel) PN (cross cable) 2) PN (standard cable) 2) PN (Mobile Panel) RS 422 to RS 232 converter RS 232 to TTY converter (20 mA) 90° angular (9-pin 1:1) Standard PROFIBUS (2-contact) 6XV1 4404Axxx 6XV1 8703RH20 Standard Ethernet CAT5 6XV1 4404Bxxx 6AV6 6718XE000AX0 6ES5 7341BD20 6AV6 6718XD000AX0 Point-topoint Key Panel KP8/KP8F, KP32F - - - P/D P/D - - - - PP7, PP17-I, PP17-II P P - - - - - - - KTP400 Basic mono PN - - - P/D/U P/D/U - - - - KTP600 Basic mono PN - - - P/D/U P/D/U - - - - KTP600 Basic color DP P/D P/D - - - - - - P/D/U KTP600 Basic color PN - - - P/D/U P/D/U - - - - KTP1000 Basic color DP P/D P/D - - - - - - P/D/U KTP1000 Basic color PN - - - P/D/U P/D/U - - - - KTP1500 Basic color PN - - - P/D/U P/D/U - - - - K(T)P400 Comfort P/D P/D - P/D/U P/D/U - - - P/D/U K(T)P700 - TP1500 Comfort P/D P/D - P/D/U P/D/U - - - P/D/U TP700 -TP2200 Comfort P/D P/D - P/D/U P/D/U - - - P/D/U MBP 177 DP P/D P/D P/D - - - - - - MBP 177 PN - - - - - P/D - - - MBP 277 P/D P/D P/D - - P/D - - - TD200 - - - - - - - - - TD400C - - - - - - - - - OP73micro P - - - - - - - - TP177micro P P - - - - - - P/D/U OP73 P P - - - - - - - OP77A P P - - - - - - P/D/U OP77B P/D P/D - - - - - P P/D/U TP177A P P - - - - - - P/D/U TP177B DP P/D P/D - - - - P P 4) P/D/U 4) P/D/U TP177B PN/DP P/D P/D - P/D P/D - P P TP177B 4" P/D P/D - P/D/U P/D/U - P P 4) P/D/U OP177B DP P/D P/D - - - - P P 4) P/D/U OP177B PN/DP P/D P/D - P/D P/D - P P 4) P/D/U TP277-6 P/D P/D - P/D P/D - P P 4) P/D/U OP277-6 P/D P/D - P/D P/D - P P 4) P/D/U MP177-6 T P/D P/D - P/D P/D - P P 4) P/D/U MP277-8 T P/D P/D - P/D P/D - P P 4) P/D/U MP277-8 K P/D P/D - P/D P/D - P P 4) P/D/U MP277-10 T P/D P/D - P/D P/D - P P 4) P/D/U MP277-10 K P/D P/D - P/D P/D - P P 4) P/D/U MP377-12 T P/D P/D - P/D/U P/D/U - P P 4) P/D MP377-12 K P/D P/D - P/D/U P/D/U - P P 4) P/D MP377-15 T P/D P/D - P/D/U P/D/U - P P 4) P/D MP377-19 T P/D P/D - P/D/U P/D/U - P P 4) P/D Note: This table is for basic orientation only. Technical characteristics are described in the communication manual or the respective user manual: 1) With gender changer 2) PROFINET IRT (Isochronous Runtime); isochronous mode only possible with IRT-enabled switch 3) Only in conjunction with the RS422/RS232 converter 6AV6 671-8XE00-0AX0 4) WinCC flexible 2008 SP2 and higher 2/114 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels SIMATIC HMI Accessories Connecting cables ■ Ordering data Order No. Connecting cables SIMATIC S7 connecting cables MPI cable 6ES7901-0BF00-0AA0 Between SIMATIC S7 and programming device via MPI max. 187.5 kBaud, standard length 5.0 m Connecting cable 6ES7901-1BF00-0XA0 Between HMI adapter and PC/TS Adapter (RS 232 cable/null-modem cable) for OP 77B, TP 177A/B, OP 177B, standard length 5.0 m Connecting cables 6XV1440-2A 2) 6XV1440-2A… Connecting cable between TD/TP/OP and AG S5 95U to -155U, 1000 m max. PROFIBUS connecting cable 830-1T For connection of data terminals, preassembled with two sub-D connectors, 9-pin terminated at both ends for PP, OP 73micro, OP 73, TP 177micro, OP 77A/B, TP 177A, TP/OP 177B • 1.5 m • 3.0 m 6XV1830-1CH15 6XV1830-1CH30 USB/PPI multi-master cable 6ES7901-3DB30-0XA0 Crossed TP cable 4 x 2, preassembled with 2 x RJ45 connectors • 1.0 m • 6.0 m • 10.0 m 6XV1870-3RH10 6XV1870-3RH60 6XV1870-3RN10 2 DP connecting cable (MPI/PROFIBUS) For wired Mobile Panels 177, Mobile Panels 277, standard lengths •2m •5m •8m • 10 m • 15 m • 20 m • 25 m 1) 6XV1440-4AH20 6XV1440-4AH50 6XV1440-4AH80 6XV1440-4AN10 6XV1440-4AN15 6XV1440-4AN20 6XV1440-4AN25 PN connecting cable (PROFINET) For connecting the S7-200 to the serial PC/OP interface Standard length 5 m PROFIBUS FC Standard Cable 2) Order No. Industrial Ethernet TP XP Cord RJ45/RJ45 For wired Mobile Panels 177, Mobile Panels 277, standard lengths •2m •5m •8m • 10 m • 15 m • 20 m • 25 m 1) 6XV1440-4BH20 6XV1440-4BH50 6XV1440-4BH80 6XV1440-4BN10 6XV1440-4BN15 6XV1440-4BN20 6XV1440-4BN25 6XV1830-0E… For connection to PPI; standard type with special design for quick mounting, 2-core, shielded, sold by the meter, max. delivery unit 1000 m, minimum ordering quantity 20 m 1) Instead of using longer cables, we recommend that you use additional connection boxes, see length code in catalog appendix. 2) See length code in catalog appendix. Note: Cable pin assignments can be found on the Internet in the online help of WinCC flexible and under FAQs http://support.automation.siemens.com This catalog only includes accessories for current products. The complete range of accessories can be found in the Mall: https://eb.automation.siemens.com or on our SIMATIC Support pages: http://support.automation.siemens.com Siemens ST 80 / ST PC · 2013 2/115 © Siemens AG 2013 Operator panels SIMATIC HMI Accessories Memory media ■ Overview SIMATIC HMI memory media are suitable for industry and optimized for the requirements in industrial environments. Special formatting and write logarithms ensure fast read/write cycles and a long service life of the memory cells. • Push Button Panels • Operator Panels • Touch Panels • Multi Panels • Comfort Panels • Mobile Panels • Industrial USB Hub 2 Memory media ■ Technical specifications 6AV6671-1CB000AX2 6AV6671-8XB100AX1 6AV2181-8XP000AX0 6AV6574-2AC002AA1 6ES7 648-0DC500AA0 SIMATIC HMI MM memory card, 128 MB SIMATIC HMI SD memory card, 512 MB SIMATIC HMI SD memory card, 2 GB SIMATIC HMI CF memory card, 512 MB SIMATIC IPC USB FLASH DRIVE, bootable, 8GB Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Supply voltage Type of supply voltage DC DC DC DC DC Rated voltage/DC 3.3 V 3.3 V 3.3 V 3.3 V 5.5 V Input current Current consumption (rated value) 60 mA 60 mA 60 mA 75 mA 60 mA Memory Type of memory Multi Media Card Secure Digital memory card Secure Digital memory card CompactFlash memory CF type I USB flash drive Size 128 Mbyte 512 Mbyte 2 048 Mbyte 512 Mbyte 8 192 Mbyte Standards, approvals, certificates CE Yes Yes Yes Yes Yes Ambient conditions Operating temperature • Operating temperature range, max. • Operating temperature range, min. 50 °C 0 °C 50 °C 0 °C 50 °C 0 °C 50 °C 0 °C 55 °C 5 °C Storage/transport temperature • Min. • max. -20 °C 60 °C -20 °C 60 °C -20 °C 60 °C -20 °C 60 °C -40 °C 70 °C Relative humidity • max. relative humidity 90 % 90 % 90 % 90 % 85 % Mechanics/material Type of housing (front) • Plastic Yes Yes Yes Yes Yes Installation type/mounting Mounting in portrait format possible Mounting in landscape format possible 2/116 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels SIMATIC HMI Accessories Memory media ■ Technical specifications (continued) 6AV6671-1CB000AX2 6AV6671-8XB100AX1 6AV2181-8XP000AX0 6AV6574-2AC002AA1 6ES7 648-0DC500AA0 SIMATIC HMI MM memory card, 128 MB SIMATIC HMI SD memory card, 512 MB SIMATIC HMI SD memory card, 2 GB SIMATIC HMI CF memory card, 512 MB SIMATIC IPC USB FLASH DRIVE, bootable, 8GB Dimensions Width 24 mm 24 mm 24 mm 42.8 mm 16.7 mm Height 32 mm 32 mm 32 mm 36.4 mm 59.1 mm Thickness 2.1 mm 2.1 mm 2.1 mm 3.3 mm 7 mm Weight Weight without packaging 3g 3g 3g 10 g 12 g Scope of supply Delivery unit in items 1 1 1 1 1 for OP 77B, TP177B, OP 177B, TP 277, OP 277, C7-635, MP 177, MP 277, MP 377, Mobile Panel 177, Mobile Panel 277, Comfort Panel for MP 177, MP 277, MP 377 and Mobile Panel 277, WinCC flexible 2008 SP1 and higher for OP 77, TP/OP 177, TP/OP 277, Mobile Panel 177, with SD/MMC slot For all Comfort Panels for SIMATIC HMI Panels and IPCs with CF slot for SIMATIC HMI devices with USB slot and SIMATIC IPC, with installed SIMATIC IPC BIOS Manager other Note: ■ Ordering data SIMATIC HMI MM memory card 128 MB Order No. 6AV6671-1CB00-0AX2 6AV6671-8XB10-0AX1 For contents and matching devices, see Technical Data in the Mall SIMATIC HMI SD memory card 2 GB Note: For delivery units/amounts, see the technical data for the relevant product. For contents and matching devices, see Technical Data in the Mall SIMATIC HMI SD memory card 512 MB 2 6AV2181-8XP00-0AX0 This catalog only includes accessories for current products. The complete range of accessories can be found in the Mall: https://eb.automation.siemens.com or on our SIMATIC Support pages: http://support.automation.siemens.com For contents and matching devices, see Technical Data in the Mall SIMATIC HMI CF memory card 512 MB 6AV6574-2AC00-2AA1 For contents and matching devices, see Technical Data in the Mall PC card adapter for CF memory card 6AV6574-2AF00-8AX0 For contents and matching devices, see Technical Data in the Mall PC memory card, 512 MB 6AV6574-2AC00-2AF1 For contents and matching devices, see Technical Data in the Mall SIMATIC IPC USB flash drive 8 GB 6ES7648-0DC50-0AA0 For contents and matching devices, see Technical Data in the Mall SIMATIC memory module for Push Button Panel 6ED1056-1BA00-0AA0 For contents and matching devices, see Technical Data in the Mall Siemens ST 80 / ST PC · 2013 2/117 © Siemens AG 2013 Operator panels SIMATIC HMI Accessories Service sets ■ Overview Service sets are available for the product groups listed below: • Push Button Panels • Key Panels • Operator Panels • Touch Panels • Multi Panels • Basic Panels • Comfort Panels • Mobile Panels • Industrial USB Hub 2 ■ Technical specifications 6AV6671-2EA000AX0 6AV6675-3AA000AX0 6AV6671-4CA000AX0 6AV6574-1AA044AA0 6AV6671-5CA000AX2 6AV6671-3EA010AX0 Service set 4" and 6" devices Service set 10" devices, Type 2 Service set 15" devices Service set Mobile Panel Service set Mobile Panel 277(F) IWLAN V2 Service set Industrial USB Hub 4 Battery Design • Special design Yes; Spare 3.6 V 1.5 Ah backup battery included in the package Standards, approvals, certificates CE Yes Yes Yes Yes Yes Yes Ambient conditions Operating temperature • Operating temperature range, max. • Operating temperature range, min. 55 °C 0 °C 55 °C 0 °C 55 °C 0 °C 55 °C 0 °C 55 °C 0 °C 55 °C 0 °C Storage/transport temperature • Min. • max. -20 °C 70 °C -20 °C 70 °C -20 °C 70 °C -20 °C 70 °C -20 °C 70 °C -20 °C 70 °C Relative humidity • max. relative humidity 95 % 95 % 95 % 95 % 95 % 95 % 2/118 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels SIMATIC HMI Accessories Service sets ■ Technical specifications (continued) 6AV6671-2EA000AX0 6AV6675-3AA000AX0 6AV6671-4CA000AX0 6AV6574-1AA044AA0 6AV6671-5CA000AX2 6AV6671-3EA010AX0 Service set 4" and 6" devices Service set 10" devices, Type 2 Service set 15" devices Service set Mobile Panel Service set Mobile Panel 277(F) IWLAN V2 Service set Industrial USB Hub 4 1; Content: 2 x seal KTP 400-TP 177B 4", 2 x seal for KTP 600, 7 x aluminum mounting clip, 1 x 2-pin female connector 1; Content: 1 x mounting seal, 10 x cast aluminum mounting clip, 1 x 2-pin female connector 1; Content: 1 x mounting seal, 1 x memory card lock, 12 x cast aluminum mounting clip, 1 x 2-pin female connector, 1 x Allen key 1; Content: 1 x blanking plug, 2 x PG cable gland A-Box, 2 x 12-pole terminal box, 1 x 3-pole terminal box, 1 x blanking cover A-Box, 2 x corner seal l/r and O-ring, 4 x decorative film for corner seal l/r 1; Content: 2 x charging station cover l/r, 1 x charging station connector, 2 x corner seal l/r, 2 x gasket corner seal, 4 x decorative film corner seal l/r, 1 x battery incl. cover, 1 x spare key 1; Content: 1 x mounting seal, 1 x mounting frame, 5 x plastic mounting clip, 1 x 2-pin female connector for KTP 400 for MP 277 10" Basic, KTP 600 Touch with stainBasic, TP 177B 4" less steel front for MP 377 15" Touch with stainless steel front for Mobile Panel 170, Mobile Panel 177 for Mobile Panel 277 IWLAN V2, Mobile Panel 277F IWLAN V2 For the Industrial USB Hub 4 6AV3678-3XC30 6AV3678-1CC10 6AV6671-1XA000AX0 6AV6574-1AA004AX0 6AV2181-8XA800AX0 6AV6671-2XA000AX0 Service set Push Button Panel Service set TD17, OP7/17 Service set OP73micro, OP73, OP77 Service set 6" devices, Type 1 Service set 6" devices, Type 2 Service set 6" devices, Type 3 Standards, approvals, certificates CE Yes Yes Yes Yes Yes Yes Ambient conditions Operating temperature • Operating temperature range, max. • Operating temperature range, min. 55 °C 0 °C 55 °C 0 °C 55 °C 0 °C 55 °C 0 °C 55 °C 0 °C 55 °C 0 °C Storage/transport temperature • Min. • max. -20 °C 70 °C -20 °C 70 °C -20 °C 70 °C -20 °C 70 °C -20 °C 70 °C -20 °C 70 °C Relative humidity • max. relative humidity 95 % 95 % 95 % 95 % 95 % 95 % 1; Content: 1 x mounting seal PP7, 1 x mounting seal PP17, 5 x plastic mounting clip, 1 x 2-pin female connector, 1 x 3-pin female connector, 1 x 4-pin female connector, 2 x 16-pin female connector 1; Content: 1 x mounting seal TD17, 1 x mounting seal OP7, 1 x mounting seal TD/OP17, 5 x plastic mounting clip 1; Content: 1 x mounting seal OP73, 1 x mounting seal OP77, 4 x plastic mounting clip, 1 x 2-pin female connector 1; Content: 3 x mounting seal, 2 x labeling strip, 7 x plastic mounting clip, 1 x 2-pin female connector 1; Content: 3 x mounting seal, 2 x labeling strip, 7 x plastic mounting clip, 20 x aluminum mounting clip, 1 x 2-pin female connector 1; Content: 1 x mounting seal TP 177, 1 x mounting seal OP 177, 7 x plastic mounting clip, 1 x 2-pin female connector for PP7, PP17-I, PP17-II for TD17, OP7, OP17 for OP73micro, OP73, OP77A, OP77B for TP 070, TP 170A/B, OP 170B, TP 170micro, OP 270 6", TP 270 6", MP 270B 6" Touch for TP 070, TP 170A/B, OP 170B, TP 170micro, OP /TP 270 6", MP 177 6"T, MP 270B 6" Touch for TP 177micro, TP 177A, TP 177B, OP 177B Scope of supply Number of sets other Note: Scope of supply Number of sets other Note: Siemens ST 80 / ST PC · 2013 2/119 2 © Siemens AG 2013 Operator panels SIMATIC HMI Accessories Service sets ■ Technical specifications (continued) 2 6AV65741AA00-2CX0 6AV65741AA00-2DX0 6AV66713XA01-0AX0 6AV66713XA01-0AX1 6AV65741AA00-2BX0 6AV66714XA00-0AX0 6AV66715CA00-0AX1 Service set 10" to 15" devices Service set 10" devices, Type 1 Service set 6" to 10" devices Service set 8" to 10" devices Service set 12" devices Service set 12" to 19" devices Service set Mobile Panel 277 (F) IWLAN V1 Battery Design • Special design Yes; Spare battery included in the package Standards, approvals, certificates CE Yes Yes Yes Yes Yes Yes Yes Ambient conditions Operating temperature • Operating temperature range, max. • Operating temperature range, min. 55 °C 0 °C 55 °C 0 °C 55 °C 0 °C 55 °C 0 °C 55 °C 0 °C 55 °C 0 °C 55 °C 0 °C Storage/transport temperature • Min. • max. -20 °C 70 °C -20 °C 70 °C -20 °C 70 °C -20 °C 70 °C -20 °C 70 °C -20 °C 70 °C -20 °C 70 °C Relative humidity • max. relative humidity 95 % 95 % 95 % 95 % 95 % 95 % 95 % 1; Content: 2 x mounting seal, 7 x mounting clip, 1 x 2-pin female connector, 1 x CF card lock, 1 x PC card lock 1; Content: 1 x slide-in labels OP 270 10" and MP 270 10" Key, 1 x mounting seal OP 270 10" and MP 270 10" Key, 10 x cast aluminum mounting clip, 1 x 2-pin female connector 1; Content: 6 x devicespecific seal, 15 x aluminum mounting clip, 1 x 2-pin female connector 1; Content: 14 x spring mounting clip, 1 x connector, female, 2-pin 1; Content: 2 x labeling strip, 6 x aluminum mounting clip, 1 x 2-pin female connector, 2 x memory card lock 1; Content: 1 x mounting seal MP 377 12" Key, 1 x mounting seal MP 377 12" Touch, 1 x mounting seal MP 377 15" Touch, 1 x mounting seal MP 377 19" Touch, 18 x aluminum mounting clip, 1 x 2-pin female connector 1; Content: 2 x charging station cover l/r, 1 x charging station connector, 2 x corner seal l/r, 2 x gasket corner seal, 4 x decorative film corner seal l/r, 1 x battery incl. cover, 1 x spare key for C7-636 Touch, TP270 10", MP270B 10" Touch, MP370 12" Touch, MP370 15" Touch for OP 270 10", MP 270B Key for TP/OP 277 6", MP 277 8" Touch, MP 277 8" Key, MP 277 10" Key product version "ES 14" and later, MP 277 10" Touch product version "ES 14" and later for MP 277 8" Touch, MP 277 8" Key product version "ES 15" and later, MP 277 10" Touch product version "ES 15" and later for MP 370 12" Key for MP 377 12" Key, MP 377 12" Touch, MP 377 15" Touch, MP 377 19" Touch for Mobile Panel 277 IWLAN, Mobile Panel 277F IWLAN Scope of supply Number of sets other Note: 2/120 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels SIMATIC HMI Accessories Service sets ■ Ordering data Service set for 4" and 6" devices Order No. 6AV6671-2EA00-0AX0 For contents and matching devices, see Technical Data Service set for 10" devices, Type 2 6AV6675-3AA00-0AX0 6AV6671-4CA00-0AX0 6AV6574-1AA04-4AA0 6AV6671-5CA00-0AX2 For contents and matching devices, see Technical Data in the Mall Service set for 10", Type 1 6AV6574-1AA00-2CX0 6AV6574-1AA00-2DX0 6AV6574-1AA00-2BX0 For contents and matching devices, see Technical Data in the Mall Service set for 12" to 19" devices 6AV6671-1XA00-0AX0 6AV6671-3XA01-0AX1 For contents and matching devices, see Technical Data in the Mall Service set for 12" devices 6AV3678-1CC10 6AV6671-3XA01-0AX0 For contents and matching devices, see Technical Data in the Mall Service set for 8" to 10" devices 6AV3678-3XC30 For contents and matching devices, see Technical Data in the Mall Service set for OP73 micro, OP73, OP77 Service set for 10" to 15" devices Service set for 6" to 10" devices 6AV6671-3EA01-0AX0 For contents and matching devices, see Technical Data in the Mall Service set for TD17, OP7/17 2 6AV6671-2XA00-0AX0 For contents and matching devices, see Technical Data in the Mall For contents and matching devices, see Technical Data Service set for pushbutton panel Service set for 6" devices, Type 3 For contents and matching devices, see Technical Data in the Mall For contents and matching devices, see Technical Data Service Kit Industrial USB Hub 4 6AV2181-8XA80-0AX0 For contents and matching devices, see Technical Data in the Mall For contents and matching devices, see Technical Data Service set for Mobile Panel 277(F) IWLAN Service set for 6" devices, Type 2 For contents and matching devices, see Technical Data in the Mall For contents and matching devices, see Technical Data Service set for Mobile Panel 6AV6574-1AA00-4AX0 For contents and matching devices, see Technical Data in the Mall For contents and matching devices, see Technical Data Service set for 15" devices Order No. Service set for 6" devices, Type 1 6AV6671-4XA00-0AX0 For contents and matching devices, see Technical Data in the Mall Service set for Mobile Panel 277(F) IWLAN V1 6AV6671-5CA00-0AX1 For contents and matching devices, see Technical Data in the Mall Note: This catalog only includes accessories for current products. The complete range of accessories can be found in the Mall: https://eb.automation.siemens.com or on our SIMATIC Support pages: http://support.automation.siemens.com Siemens ST 80 / ST PC · 2013 2/121 © Siemens AG 2013 Operator panels SIMATIC HMI Accessories Protective covers ■ Overview Protective covers with IP65 degree of protection provide complete frontal protection of the panel against dirt and scratches; the protective covers can be kept clean using highpressure cleaning equipment. Ready-made templates can be downloaded to help you create and print out your own low-cost frame designs between panel and protective cover. 2 Adhesive protective membranes are available for simple display protection. Protective covers are available for the following SIMATIC HMI Panels: • Touch Panels • Operator Panels • Multi Panels ■ Technical specifications 6AV6574-1AE004AX0 6AV6671-1AJ000AX0 6AV6671-2DJ000AX0 6AV6671-3CK010AX0 6AV6671-3CK000AX0 Protective cover 6" Touch devices Protective cover OP77 Protective cover OP177 Protective cover MP 277 8" Touch Protective cover MP 277 10" Touch Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Degree and class of protection IP (at the front) IP65 IP65 IP65 IP65 IP65 Standards, approvals, certificates CE Yes Yes Yes Yes Yes Ambient conditions Operating temperature • Operating temperature range, max. • Operating temperature range, min. 50 °C 0 °C 50 °C 0 °C 50 °C 0 °C 50 °C 0 °C 50 °C 0 °C Storage/transport temperature • Min. • max. -20 °C 60 °C -20 °C 60 °C -20 °C 60 °C -20 °C 60 °C -20 °C 60 °C Relative humidity • max. relative humidity 95 % 95 % 95 % 95 % 95 % Mechanics/material Plastic Yes Yes Yes Yes Yes Dimensions Width 242.3 mm 178.6 mm 274.3 mm 270.8 mm 355.8 mm Height 186.3 mm 214.6 mm 243.26 mm 211 mm 294 mm Thickness 10 mm 7.8 mm 7.8 mm 7.8 mm 7.8 mm Height of housing front • Mounting cutout, width • Mounting cutout, height 198 mm 142 mm 135 mm 171 mm 229 mm 196 mm 226 mm 166 mm 310 mm 248 mm Weight Weight without packaging 750 g 750 g 750 g 750 g 750 g Installation type/mounting Mounting in portrait format possible Mounting in landscape format possible 2/122 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels SIMATIC HMI Accessories Protective covers ■ Technical specifications (continued) Scope of supply Number of sets other Note: ■ Ordering data Protective covers for 6" Touch devices 6AV6574-1AE004AX0 6AV6671-1AJ000AX0 6AV6671-2DJ000AX0 6AV6671-3CK010AX0 6AV6671-3CK000AX0 Protective cover 6" Touch devices Protective cover OP77 Protective cover OP177 Protective cover MP 277 8" Touch Protective cover MP 277 10" Touch 2; 2 cover frames, 2 base frames, 2 protective covers, molded (for TP 070, TP 170micro, TP 170A/B), 2 protective covers, smooth (for TP 177micro, TP 177A/B, TP 270 6", MP 177 6" Touch, MP 270 6" Touch) 2; 2 cover frames, 2 base frames, 2 protective covers 2; 2 cover frames, 2 base frames, 2 protective covers 2; 2 cover frames, 2 base frames, 2 protective covers 2; 2 cover frames, 2 base frames, 2 protective covers for TP 070, TP 170A, TP 170B, TP 170micro, TP 177micro, TP 177A, TP 177B, TP 270 6 ", TP 277 6 ", MP 270 6" Touch for OP 77A, OP 77B For OP177B for MP 277 8" Touch as far as product version "ES 14" with narrow frame for MP 277 10" Touch up to product version "ES 14 ", Thin Client 10" up to "ES 03" (6AV6646-0AA212AX0) with narrow frame Order No. 6AV6574-1AE00-4AX0 This catalog only includes accessories for current products. For TP 070, TP 170micro, TP 177micro, TP 170A/B, TP 177A/B, TP 270 6", TP 277 6", MP 177 6" Touch, MP 270 6" Touch consisting of: see technical data Protective covers for OP 77 Note: The complete range of accessories can be found in the Mall: https://eb.automation.siemens.com 6AV6671-1AJ00-0AX0 or on our SIMATIC Support pages: http://support.automation.siemens.com For OP77 and OP77B consisting of: see technical data Protective covers for OP 177 6AV6671-2DJ00-0AX0 For OP177B consisting of: see technical data Protective covers for MP 277 8" Touch devices 6AV6671-3CK01-0AX0 Only suitable for MP 277 8" Touch up to E14 1) (for devices with a narrow frame geometry) consisting of: see technical data Protective covers for MP 277 10" Touch devices 6AV6671-3CK00-0AX0 Only suitable for MP 277 10" Touch up to E14 1) and 10" Thin Client up to E03 2) (for devices with a narrow frame geometry) consisting of: see technical data 1) E14 = Product version 14 2) E03 = Product version 03 Siemens ST 80 / ST PC · 2013 2/123 2 © Siemens AG 2013 Operator panels SIMATIC HMI Accessories Protective films ■ Overview Protective films for: • Touch Panels • C7 devices • Multi Panels • Thin Clients • Touch Panels • Basic Panels • Comfort Panels • Mobile Panels 2 Protective films protect the display from dirt and scratching during operation and use. For complete protection of the front side in harsh environments, protective covers are available for some devices. Note: During installation, the protective films must completely cover the display. For compatibility reasons, not all protective films extend as far as the edge of the enclosure. This does not, however, affect the protective function. 2/124 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels SIMATIC HMI Accessories Protective films ■ Technical specifications 6AV6671-2EC000AX0 6AV6671-2XC000AX0 6AV6574-1AD044AA0 6AV6671-5BC000AX0 6AV6645-7AB150AS0 6AV6671-3DC000AX0 Protective film 4" Touch devices Protective film 6" Touch devices, Type 3 Protective film 6" Touch devices, Type 10 Protective film 8" Touch devices, Type 10 Protective film 10" Touch devices, Type 10 Protective film 10" Thin Client and MP277 up to ES14 Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Standards, approvals, certificates CE Yes Yes Yes Yes Yes Yes Ambient conditions Operating temperature • Operating temperature range, max. • Operating temperature range, min. 50 °C 0 °C 50 °C 0 °C 50 °C 0 °C 50 °C 0 °C 50 °C 0 °C 50 °C 0 °C Storage/transport temperature • Min. • max. -20 °C 60 °C -20 °C 60 °C -20 °C 60 °C -20 °C 60 °C -20 °C 60 °C -20 °C 60 °C Relative humidity • max. relative humidity 90 % 90 % 90 % 90 % 90 % 90 % Films printable with laser printer Yes Yes Yes Yes Yes Yes Yes; Nonreflecting Yes; Nonreflecting Yes; Nonreflecting Yes; Nonreflecting Yes; Nonreflecting Yes; Nonreflecting Dimensions Width 120 mm 179.4 mm 120.5 mm 155.5 mm 223.17 mm 292 mm Height 105 mm 141.4 mm 91 mm 124.9 mm 170.37 mm 248 mm Thickness 0.125 mm 0.125 mm 0.125 mm 0.3 mm 0.3 mm 0.125 mm Scope of supply Delivery unit in items 10 10 10 2 10 10 for TP 177B 4", KTP 400 Basic for TP 177micro, TP 177A, TP 177B, OP 177B, KTP 600 Basic for Mobile Panel 170, Mobile Panel 177 for Mobile Panel 277 8" for Mobile Panel 277 10" Installation type/mounting Mounting in portrait format possible Mounting in landscape format possible Mechanics/material Plastic other Note: Siemens ST 80 / ST PC · 2013 2 2/125 © Siemens AG 2013 Operator panels SIMATIC HMI Accessories Protective films ■ Technical specifications (continued) 2 6AV6671-3DC000AX5 6AV6574-1AD004EX0 6AV2124-6DJ000AX0 6AV2124-6GJ000AX0 6AV2124-6JJ000AX0 6AV2124-6MJ000AX0 Protective film 10" Key Panel, Thin Client and MP277 as of ES15 Protective film 15" TP1500, MP370/377 and ThinClient Protective film 4" widescreen Protective film 7" widescreen Protective film 9" widescreen Protective film 12" widescreen Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Standards, approvals, certificates CE Yes Yes Yes Yes Yes Yes Ambient conditions Operating temperature • Operating temperature range, max. • Operating temperature range, min. 50 °C 0 °C 50 °C 0 °C 50 °C 0 °C 50 °C 0 °C 50 °C 0 °C 50 °C 0 °C Storage/transport temperature • Min. • max. -20 °C 60 °C -20 °C 60 °C -20 °C 60 °C -20 °C 60 °C -20 °C 60 °C -20 °C 60 °C Relative humidity • max. relative humidity 90 % 90 % 90 % 90 % 90 % 90 % Films printable with laser printer Yes Yes Yes Yes Yes Yes Yes; Nonreflecting Yes; Nonreflecting Yes; Nonreflecting Yes; Nonreflecting Yes; Nonreflecting Yes; Nonreflecting Dimensions Width 299.8 mm 362 mm 131.4 mm 205.4 mm 265.4 mm 321.4 mm Height 259.9 mm 289 mm 107.4 mm 149.4 mm 181.4 mm 232.4 mm Thickness 0.125 mm 0.125 mm 0.125 mm 0.125 mm 0.125 mm 0.125 mm Scope of supply Delivery unit in items 10 10 10 10 10 10 for KTP400 Comfort, KTP400 Basic color PN for TP700 Comfort, IPC277D for TP900 Comfort, IPC277D for TP1200 Comfort, IPC277D Installation type/mounting Mounting in portrait format possible Mounting in landscape format possible Mechanics/material Plastic other Note: 2/126 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels SIMATIC HMI Accessories Protective films ■ Technical specifications (continued) 6AV2124-6QJ00-0AX1 6AV2124-6UJ00-0AX1 6AV2124-6XJ00-0AX1 Protective film 15" widescreen Protective film 19" widescreen Protective film 22" widescreen Yes Yes Yes Yes Yes Yes Standards, approvals, certificates CE Yes Yes Yes Ambient conditions Operating temperature • Operating temperature range, max. • Operating temperature range, min. 50 °C 0 °C 50 °C 0 °C 50 °C 0 °C Storage/transport temperature • Min. • max. -20 °C 60 °C -20 °C 60 °C -20 °C 60 °C Relative humidity • max. relative humidity 90 % 90 % 90 % Films printable with laser printer Yes Yes Yes Mechanics/material Plastic Yes; Nonreflecting Yes; Nonreflecting Yes; Nonreflecting Dimensions Width 368 mm 451 mm 518 mm Height 231 mm 285 mm 334 mm Thickness 0.125 mm 0.125 mm 0.125 mm Weight Weight without packaging 26 g; Per unit 34 g; Per unit 44 g; Per unit Scope of supply Delivery unit in items 10 10 10 for Comfort Panel, IPC, Flat Panel, Thin Client for Comfort Panel, IPC, Flat Panel, Thin Client for Comfort Panel, IPC, Flat Panel, Thin Client Installation type/mounting Mounting in portrait format possible Mounting in landscape format possible other Note: Siemens ST 80 / ST PC · 2013 2 2/127 © Siemens AG 2013 Operator panels SIMATIC HMI Accessories Protective films ■ Technical specifications (continued) 2 6AV6574-1AD004DX0 6AV6574-1AD004CX0 6AV6671-2XC000AX0 6AV6671-3CC000AX0 6AV6671-3CC000AX5 6AV7672-1CE000AA0 Protective film 6" Touch devices, Type 2 Protective film 10" - 12" TP/MP 270/370/377 and C7-636 Protective film 6" Touch devices, Type 3 Protective film 8" Touch devices, Type 1 Protective film 8" Touch devices, Type 2 Protective film 19" MP377, panel PC and Flat Panel Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Standards, approvals, certificates CE Yes Yes Yes Yes Yes Yes Ambient conditions Operating temperature • Operating temperature range, max. • Operating temperature range, min. 50 °C 0 °C 50 °C 0 °C 50 °C 0 °C 50 °C 0 °C 50 °C 0 °C 50 °C 0 °C Storage/transport temperature • Min. • max. -20 °C 60 °C -20 °C 60 °C -20 °C 60 °C -20 °C 60 °C -20 °C 60 °C -20 °C 60 °C Relative humidity • max. relative humidity 90 % 90 % 90 % 90 % 90 % 90 % Films printable with laser printer Yes Yes Yes Yes Yes Yes Yes; Nonreflecting Yes; Nonreflecting Yes; Nonreflecting Yes; Nonreflecting Yes; Nonreflecting Yes; Nonreflecting Dimensions Width 178.4 mm 297.4 mm 179.4 mm 207 mm 217 mm 378 mm Height 135.4 mm 254.4 mm 141.4 mm 165 mm 217 mm 302.5 mm Thickness 0.125 mm 0.125 mm 0.125 mm 0.125 mm 0.125 mm 0.2 mm Scope of supply Delivery unit in items 10 10 10 10 10 10 for TP 177micro, TP 177A, TP 177B, OP 177B, KTP 600 Basic for MP 277 8" Touch up to product version "ES 14" for MP 277 8" Touch in product version "ES 15" and later Installation type/mounting Mounting in portrait format possible Mounting in landscape format possible Mechanics/material Plastic other Note: 2/128 for TP 270 6", TP 277 6", MP 177 6" Touch, MP 270B 6" Touch Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels SIMATIC HMI Accessories Protective films ■ Ordering data Protective films for 4" Touch devices Order No. Protective films for 6" Touch devices, type 1 For contents and matching devices, see Technical Data and Mall 6AV6574-1AD00-4AX0 6AV6671-2XC00-0AX0 Protective films for 6" Touch devices, type 4 For contents and matching devices, see Technical Data and Mall 6AV3672-2CS00 Protective films for 10" Touch devices, type 3 6AV3672-2CS11 For contents and matching devices, see Technical Data and Mall Protective films for 6" Touch devices, type 4 For contents and matching devices, see Technical Data and Mall Protective films for 6" Touch devices, type 10 6AV6574-1AD04-4AA0 6AV6671-5BC00-0AX0 6AV6645-7AB15-0AS0 6AV6671-3DC00-0AX0 6AV6671-3DC00-0AX5 6AV6574-1AD00-4EX0 6AV2124-6DJ00-0AX0 For contents and matching devices, see Technical Data and Mall Protective films 7" widescreen Protective films for 6" Touch devices, type 3 6AV6671-2XC00-0AX0 Protective films for 8" Touch devices, type 1 6AV6671-3CC00-0AX0 Protective films for 8" Touch devices, type 2 6AV6671-3CC00-0AX5 For contents and matching devices, see Technical Data and Mall For contents and matching devices, see Technical Data and Mall Protective films 4" widescreen 6AV6574-1AD00-4CX0 For contents and matching devices, see Technical Data and Mall For contents and matching devices, see Technical Data and Mall Protective films for 15" Touch devices Protective films for 10" to 12" Touch devices For contents and matching devices, see Technical Data and Mall For contents and matching devices, see Technical Data and Mall Protective films for 10" Touch devices, type 2 6AV6574-1AD00-4DX0 For contents and matching devices, see Technical Data and Mall For contents and matching devices, see Technical Data and Mall Protective films for 10" Touch devices, type 1 Protective films for 10" Touch devices, type 2 For contents and matching devices, see Technical Data and Mall For contents and matching devices, see Technical Data and Mall Protective films for 10" Touch devices, type 10 2 For contents and matching devices, see Technical Data and Mall For contents and matching devices, see Technical Data and Mall Protective films for 8" Touch devices, type 10 Order No. 6AV6671-2EC00-0AX0 Protective films for 19" Touch devices 6AV7672-1CE00-0AA0 For contents and matching devices, see Technical Data and Mall 6AV2124-6GJ00-0AX0 For contents and matching devices, see Technical Data and Mall Protective films 9" widescreen 6AV2124-6JJ00-0AX0 For contents and matching devices, see Technical Data and Mall Protective films 12" widescreen 6AV2124-6MJ00-0AX0 For contents and matching devices, see Technical Data and Mall Protective films 15" widescreen 6AV2124-6QJ00-0AX1 For contents and matching devices, see Technical Data and Mall Protective films 19" widescreen 6AV2124-6UJ00-0AX1 For contents and matching devices, see Technical Data and Mall Protective films 22" widescreen 6AV2124-6XJ00-0AX1 For contents and matching devices, see Technical Data and Mall Note: This catalog only includes accessories for current products. The complete range of accessories can be found in the Mall: https://eb.automation.siemens.com or on our SIMATIC Support pages: http://support.automation.siemens.com Siemens ST 80 / ST PC · 2013 2/129 © Siemens AG 2013 Operator panels SIMATIC HMI Accessories Fasteners ■ Overview All parts required to install a SIMATIC HMI Panel are listed here. Mounting frames enable compliance with device-specific degrees of protection IP65, NEMA4x and NEMA12 (indoor only) if the thickness of the mounting plate is less than the minimum plate thickness specified in the operating instructions. The mounting frame has been specially developed for plate thicknesses of less than 2 mm. 2 Depending on the device, different mounting clips are available for attaching the panel. Memory card locks (snappable and slideable) are also available to secure memory cards in the SIMATIC HMI Comfort Panels. • Push Button Panel • Key Panel • Text Display • Operator Panel • Touch Panel • Multi Panel • Basic Panel • Comfort Panel Note regarding Industrial USB Hub 4: The mounting frame is only available in the service pack 6AV6671-3EA01-0AX0. ■ Technical specifications 6AV6671-3CS00-0AX0 6AV6671-3CS01-0AX0 6AV6671-8XS00-0AX0 Mounting frame 8" Touch Mounting frame 8" Key Mounting frame 10" to 12" Touch devices Installation type/mounting Mounting in portrait format possible Yes Yes Yes Mounting in landscape format possible Yes Yes Yes Standards, approvals, certificates CE Yes Yes Yes Ambient conditions Operating temperature • Operating temperature range, max. • Operating temperature range, min. 55 °C 0 °C 55 °C 0 °C 55 °C 0 °C Storage/transport temperature • Min. • max. -20 °C 70 °C -20 °C 70 °C -20 °C 70 °C Relative humidity • max. relative humidity 90 % 90 % 90 % Mechanics/material Type of housing (front) • Sheet steel Yes Yes Yes Scope of supply Delivery unit in items 1 1 1 other Note: For MP 277 8" Touch For MP 277 8" Key For KTP1000 Basic, MP 277 10" Touch, MP 377 12" Touch, Thin Client 10" 2/130 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels SIMATIC HMI Accessories Fasteners ■ Technical specifications (continued) 6AV6671-8XK00-0AX2 6AV6671-8XK00-0AX1 6AV6671-8XK00-0AX0 Mounting clip, plastic Mounting clip, spring Mounting clip, aluminum Installation type/mounting Mounting in portrait format possible Yes Yes Yes Mounting in landscape format possible Yes Yes Yes Standards, approvals, certificates CE Yes Yes Yes Ambient conditions Operating temperature • Operating temperature range, max. • Operating temperature range, min. 55 °C 0 °C 55 °C 0 °C 55 °C 0 °C Storage/transport temperature • Min. • max. -20 °C 70 °C -20 °C 70 °C -20 °C 70 °C Relative humidity • max. relative humidity 90 % 90 % 90 % Mechanics/material Screw type • 4.5 V Yes; Original partially Phillips screw Type of housing (front) • Plastic • Aluminum Yes 2 Yes Yes Yes Dimensions Width 30 mm 20 mm 15 mm Height 17 mm; Without screw 35 mm 21 mm; Without screw Thickness 8 mm 20 mm 15 mm Weight Weight without packaging 4 g; Per unit 8 g; Per unit 5 g; Per unit Scope of supply Delivery unit in items 20 20 20 TD17, OP7/17/73, OP77A/B, TP/OP170, KP300 mono, KTP400 color, TP/OP177 except TP177 4", MP270-6T, TP/OP270-6" TP177-4", TP/OP 277-6", MP177-6, MP277-10" T, MP277-8", MP277-8"T, MP277-10"K, MP377 12-19", TC 10", TC 15", KTP400 Basic mono, KTP600, KTP1000, KTP1500, KP700 Comfort, TP700 Comfort, KP900 Comfort, TP900 Comfort, KP1200 Comfort, TP1200 Comfort and IPC 277D 7, 9, 12" TP177-4", TP/OP 277-6", MP177-6, MP277-10" T, MP277-8", MP277-8"T, MP277-10"K, MP377 12-19", TC 10", TC 15", KTP400 Basic mono, KTP600, KTP1000, KTP1500, KP700 Comfort, TP700 Comfort, KP900 Comfort, TP900 Comfort, KP1200 Comfort, TP1200 Comfort and IPC 277D 7, 9, 12" other Note: Siemens ST 80 / ST PC · 2013 2/131 © Siemens AG 2013 Operator panels SIMATIC HMI Accessories Fasteners ■ Technical specifications (continued) 2 6AV6671-8XK00-0AX3 6AV6671-8XK00-0AX4 Mounting clip, steel Mounting bracket, steel Installation type/mounting Mounting in portrait format possible Yes Yes Mounting in landscape format possible Yes Yes Standards, approvals, certificates CE Yes Yes Ambient conditions Operating temperature • Operating temperature range, max. • Operating temperature range, min. 55 °C 0 °C 55 °C 0 °C Storage/transport temperature • Min. • max. -20 °C 70 °C -20 °C 70 °C Relative humidity • max. relative humidity 90 % 90 % Mechanics/material Screw type • 4.5 V Yes Yes Type of housing (front) • Sheet steel Yes Yes Dimensions Width 20 mm 142 mm Height 15 mm; Without screw 18 mm; Without screw Thickness 8 mm 8 mm Scope of supply Delivery unit in items 20 10 15", 19" and 22" widescreen - Comfort Panels, IPCs, Flat Panels and Thin Clients. Plate thicknesses up to 6 mm 15", 19" and 22" widescreen - Comfort Panels, IPCs, Flat Panels and Thin Clients, except SCD1900 19" widescreen. Plate thicknesses up to 6 mm other Note: 2/132 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels SIMATIC HMI Accessories Fasteners ■ Technical specifications (continued) 6AV2181-4DM10-0AX0 6AV2181-4XM00-0AX0 Memory card lock 4" Memory card lock 7" - 22" Installation type/mounting Wall mounting/direct mounting possible Yes; Snap-on Yes; Snap-on Degree and class of protection IP (at the front) 20 20 Standards, approvals, certificates CE Yes Yes Ambient conditions Operating temperature • Operating temperature range, max. • Operating temperature range, min. 55 °C 0 °C 55 °C 0 °C Storage/transport temperature • Min. • max. -20 °C 70 °C -20 °C 70 °C Relative humidity • max. relative humidity 90 % 90 % Mechanics/material Plastic Yes Yes Dimensions Width 25 mm 45 mm Height 30 mm 59 mm Thickness 10 mm 12 mm Weight Weight without packaging 4 g; Per unit 6 g; Per unit Scope of supply Delivery unit in items 5 5 other Note: Comfort Panel 4" Comfort Panels 7" to 22" 2 Siemens ST 80 / ST PC · 2013 2/133 © Siemens AG 2013 Operator panels SIMATIC HMI Accessories Fasteners ■ Ordering data Mounting frame 8" Touch Order No. 6AV6671-3CS00-0AX0 For contents and matching devices, see Technical Data and Mall Mounting frame for 8" Key 2 4" memory card lock 6AV6671-3CS01-0AX0 For contents and matching devices, see Technical Data and Mall Mounting frame 10"/12" Touch Order No. Mounts and interlocks 7" … 22" memory card lock 6AV6671-8XS00-0AX0 6AV2181-4DM10-0AX0 For contents and matching devices, see Technical Data and Mall 6AV2181-4XM00-0AX0 For contents and matching devices, see Technical Data and Mall For contents and matching devices, see Technical Data and Mall Mounting clip/bracket Plastic mounting clip 6AV6671-8XK00-0AX2 For contents and matching devices, see Technical Data and Mall Spring mounting clip 6AV6671-8XK00-0AX1 For contents and matching devices, see Technical Data and Mall Aluminum mounting clip 6AV6671-8XK00-0AX0 For contents and matching devices, see Technical Data and Mall Steel mounting clip 6AV6671-8XK00-0AX3 For contents and matching devices, see Technical Data and Mall Steel mounting bracket 6AV6671-8XK00-0AX4 For contents and matching devices, see Technical Data and Mall Note: This catalog only includes accessories for current products. The complete range of accessories can be found in the Mall: https://eb.automation.siemens.com or on our SIMATIC Support pages: http://support.automation.siemens.com 2/134 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels SIMATIC HMI Accessories Labeling strips ■ Overview Labeling strips and membranes are available for: • Text display • Multi Panel • Mobile Panel The labeling strips, blank membranes, and protective membranes should be printed at a printing works. Templates can be used to create labeling strips for SIMATIC HMI devices. Alternatively, a tool for the creation of labeling strips is available. Download templates from: http://support.automation.siemens.com/WW/view/en/11274631 and download Label Creator from: http://support.automation.siemens.com/WW/view/en/61507590 Labeling strips Protective cover for labeling strips for Mobile Panel 170, Mobile Panel 177 ■ Technical specifications 6AV6574-1AB044AA0 6AV6671-5BF000AX0 6AV6574-1AB002BA0 6ES7272-1BF007AA0 6ES7272-1AF007AA0 6AV6671-0AP000AX0 Protective sleeve labeling strips Labeling set Mobile Panel 277 Labeling strip MP 37x Key Front membrane TD100C, blank Front membrane TD200C, blank Front membrane TD400C, blank Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Standards, approvals, certificates CE Yes Yes Yes Yes Yes Yes Ambient conditions Operating temperature • Operating temperature range, max. • Operating temperature range, min. 50 °C 0 °C 50 °C 0 °C 50 °C 0 °C 50 °C 0 °C 50 °C 0 °C 50 °C 0 °C Storage/transport temperature • Min. • max. -20 °C 60 °C -20 °C 60 °C -20 °C 60 °C -20 °C 60 °C -20 °C 60 °C -20 °C 60 °C Relative humidity • max. relative humidity 90 % 90 % 90 % 90 % 90 % 90 % Installation type/mounting Mounting in portrait format possible Mounting in landscape format possible Siemens ST 80 / ST PC · 2013 2/135 2 © Siemens AG 2013 Operator panels SIMATIC HMI Accessories Labeling strips ■ Technical specifications (continued) 2 6AV6574-1AB044AA0 6AV6671-5BF000AX0 6AV6574-1AB002BA0 6ES7272-1BF007AA0 6ES7272-1AF007AA0 6AV6671-0AP000AX0 Protective sleeve labeling strips Labeling set Mobile Panel 277 Labeling strip MP 37x Key Front membrane TD100C, blank Front membrane TD200C, blank Front membrane TD400C, blank Films Number of films per sheet 6 3 2 Yes Yes Yes Yes Yes Dimensions Width 210 mm 210 mm 210 mm 210 mm 210 mm Height 297 mm 297 mm 297 mm 297 mm 297 mm printable with laser printer 6 No Width of the housing front 163 mm Height of housing front 91 mm Scope of supply Delivery unit in items 5 Number of sets other Note: for Mobile Panel 170, Mobile Panel 177 ■ Ordering data Protective cover for Mobile Panel 17x 2 1 10 10 10 6 2 60 30 20 For Mobile Panel 277 For MP 370 Key, MP 377 Key For TD100C For TD200C For TD400C Order No. 6AV6574-1AB04-4AA0 This catalog only includes accessories for current products. For contents and matching devices, see Technical Data in the Mall Labeling set for Mobile Panel 277 6AV6671-5BF00-0AX0 6AV6574-1AB00-2BA0 For contents and matching devices, see Technical Data in the Mall Front membrane TD100C, unprinted 6ES7272-1BF00-7AA0 For contents and matching devices, see Technical Data in the Mall Front membrane TD200C, unprinted 6ES7272-1AF00-7AA0 For contents and matching devices, see Technical Data in the Mall Front membrane TD400C, unprinted 6AV6671-0AP00-0AX0 For contents and matching devices, see Technical Data in the Mall 2/136 The complete range of accessories can be found in the Mall: https://eb.automation.siemens.com or on our SIMATIC Support pages: http://support.automation.siemens.com For contents and matching devices, see Technical Data in the Mall Labeling set for MP 377 Key Note: Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Operator panels SIMATIC HMI Accessories Batteries ■ Overview 2 Rechargeable buffer battery for Mobile Panel Lithium battery for SIMATIC HMI, C7 and S7 ■ Technical specifications W790 84-E1001-B2 6ES7 623-1AE01-5AA0 6AV6 671-5CL00-0AX0 6AV6 671-5AD00-0AX0 Lithium battery SIMATIC HMI and C7 Lithium battery SIMATIC HMI, C7 and S7 Main battery Mobile Panel IWLAN Rechargeable back-up battery Mobile Panel Installation type/mounting Wall mounting/direct mounting possible Yes; in HMI devices, battery compartment Yes; in HMI devices, battery compartment Yes; in HMI devices, battery compartment Yes; in HMI devices, battery compartment Supply voltage Type of supply voltage DC DC DC DC Rated voltage/DC 3.6 V; 1.6 Ah 3.6 V; 1.6 Ah 7.2 V; 5.1 Ah 3.6 V; 1.15 Ah Battery Design • Special design Yes; 2/3 AA Yes; 2/3 AA Yes; bent Yes; flat Technology • Lithium-ion Yes; SL-361 Yes; SL-361 Yes; 2ICR19/65-2 CGR Yes; 1/CP7/34/50 01 CGA Standards, approvals, certificates CE Yes Yes Yes Yes Ambient conditions Operating temperature • Operating temperature range, max. • Operating temperature range, min. 55 °C 0 °C 55 °C 0 °C 55 °C 0 °C; Don't charge below 55 °C 0 °C; Don't charge below Storage/transport temperature • Min. • max. -20 °C 70 °C -55 °C 85 °C -20 °C 70 °C -20 °C 70 °C Relative humidity • max. relative humidity 90 % 90 % 90 % 90 % 75 mm 35 mm Height 33 mm; Length 33 mm; Length 78 mm 50 mm Thickness 14.7 mm; Diameter 14.7 mm; Diameter 33 mm 10 mm Weight Weight without packaging 12 g 14 g 320 g 38 g 1; incl. 220 mm connecting cable 1; Incl. 45 mm + 210 mm connecting cable 1 1; incl. 65 mm connecting cable for TD17, OP17, OP25, OP27, OP35, OP37, TP27, TP37, OP/TP270, MP 270, MP 270B, MP 370, C7-621, C7-623, C7-624, C7-626 and PG 7xx for TD17, OP17, OP25, OP27, OP35, OP37, TP27, TP37, OP/TP270, MP 270, MP 270B, MP 370, C7-621, C7-623, C7-624, C7-626 and PG 7xx for Mobile Panel 277 IWLAN, Mobile Panel 277F IWLAN, Mobile Panel 277 IWLAN V2, Mobile Panel 277F IWLAN V2, Mobile Panel 277F IWLAN (RFID tag) for Mobile Panel DP cabled, Mobile Panel PN cabled, Mobile Panel 277 IWLAN, Mobile Panel 277F IWLAN Dimensions Width Scope of supply Delivery unit in items other Note: Siemens ST 80 / ST PC · 2013 2/137 © Siemens AG 2013 Operator panels SIMATIC HMI Accessories Batteries ■ Ordering data Lithium battery for SIMATIC HMI and C7 Order No. W79084-E1001-B2 This catalog only includes accessories for current products. For contents and matching devices, see Technical Data Lithium battery for SIMATIC PG7xx, HMI and C7 2 6ES7623-1AE01-5AA0 6AV6671-5CL00-0AX0 For contents and matching devices, see Technical Data Rechargeable buffer battery for Mobile Panel 6AV6671-5AD00-0AX0 For contents and matching devices, see Technical Data 2/138 The complete range of accessories can be found in the Mall: https://eb.automation.siemens.com or on our SIMATIC Support pages: http://support.automation.siemens.com incl. 250 mm adapter cable Main rechargeable battery for Mobile Panel IWLAN Note: Siemens ST 80 / ST PC · 2013 3 © Siemens AG 2013 HMI devices for special requirements 3/2 Introduction 3/3 3/4 3/7 3/12 3/14 3/16 3/16 3/17 3/19 3/20 Fully enclosed HMI devices SIMATIC MP 377 PRO SIMATIC HMI IPC477C PRO SIMATIC Flat Panel PRO SIMATIC Thin Client PRO Accessories for fully enclosed HMI devices Adapter sets Extension units IP65 keyboards USB interfaces 3/21 3/22 Devices with stainless steel front SIMATIC HMI IPC677C INOX 3/25 3/26 3/30 HMI devices for hazardous areas SIMATIC HMI Panel PC Ex SIMATIC HMI Thin Client Ex Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 HMI devices for special requirements Introduction ■ Overview Fully enclosed HMI devices The fully enclosed SIMATIC HMI devices (MP 377 PRO, HMI IPC477C PRO, Flat Panel PRO and Thin Client PRO) are specially designed for mounting on a support arm/stand. Thanks to their extremely rugged design, the devices are ideal for industrial applications in harsh environments. Devices with stainless steel front For special requirements, the HMI IPC677C INOX with stainless steel front for use in the food and beverages industry. HMI devices for hazardous areas 3 The SIMATIC HMI Ex devices (HMI Panel PC Ex and HMI Thin Client Ex) are intrinsically safe Panel PCs and Thin Clients that have been specially developed for hazardous areas "Zone 1" and "Zone 2". Further SIMATIC HMI devices are also available for the hazardous area "Zone 2" and can be found in the chapter "Operator panels". 3/2 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 HMI devices for special requirements Fully enclosed HMI devices Overview ■ Overview The SIMATIC HMI PRO devices can be mounted direct on the support arm head of the desired support arm system using the basic adapter supplied. The adapter set can be ordered separately. The basic adapter can be attached to the top or bottom of the device. The connecting cables are run through the support arm. With the extension units, the range of possible on-site operations can be expanded. The extension units can be mounted on the right and/or left side of the SIMATIC HMI PRO device and can be equipped individually with, for example, illuminated pushbuttons, emergency stop buttons, RFID readers, etc. The SIMATIC HMI PRO (PRO = protected) devices have been designed for mounting on a support arm/pedestal. Thanks to their rugged aluminum enclosures, the SIMATIC HMI PRO devices offer overall IP65 protection and are also suitable for use in harsh environments. The separation of HMI and control cabinet allows flexible design concepts. The SIMATIC HMI PRO devices are used wherever the HMI device cannot be installed direct in the control cabinet due to restricted space, or whenever an operator control unit is required direct at the machine. All the devices are fan-free, and only standard connecting cables are used. The following are available as SIMATIC fully enclosed HMI devices: • SIMATIC MP 377 PRO 15" Touch: Multi Panel for operator control and monitoring of machines and plants • SIMATIC HMI IPC477C PRO 15"/19" Touch: Compact, high-performance and maintenance-free embedded IPC • SIMATIC Flat Panel PRO 15"/19" Touch: Industrial monitor with touch functionality, can be located up to 30 m from the operator control unit (as with Flat Panel Extended) • SIMATIC Thin Client PRO 15" Touch: HMI device for terminal and web client applications Siemens ST 80 / ST PC · 2013 3/3 3 © Siemens AG 2013 HMI devices for special requirements Fully enclosed HMI devices SIMATIC MP 377 PRO ■ Overview ■ Technical specifications MP 377 PRO 15" 15" (304.1 mm x 228.1 mm) Display type TFT, 65536 colors Resolution (pixels) • Resolution (WxH in pixel) 1024 x 768 Backlighting • MTBF backlighting (at 25 °C) about 50000 hours Control elements Control elements Touch screen Connection for mouse/keyboard/ barcode reader 3 SIMATIC MP 377 PRO 15" Analog, resistive Supply voltage Supply voltage 24 V DC Input current Rated current 1.8 A Memory Type Flash / RAM Time of day Clock • Type Interfaces Interfaces Siemens ST 80 / ST PC · 2013 USB / USB / USB Touch operation • Touch screen Usable memory for user data 3/4 6AV6 644-2AB01-2AX0 Display Size 12288 KB usable memory for user data / 12288 KB additional memory for options Hardware clock, battery backup, synchronizable 1 x RS422, 1 x RS485, 2 x Ethernet (RJ45) USB port 2 x USB CF card slot 1 x CF card slot Multi Media Card slot 1 x Multi Media Card slot Industrial Ethernet • Industrial Ethernet interface 2 x Ethernet (RJ45) Protocols Protocols (terminal link) • Sm@rtServer Yes Degree and class of protection Front IP65, NEMA 4, (when installed) Rear IP65 Standards, approvals, certificates Certifications CE, cULus, C-TICK, NEMA 4 FM Class I Div. 2 No Suitable for safety functions No Use in hazardous areas • EX zone 22 No © Siemens AG 2013 HMI devices for special requirements Fully enclosed HMI devices SIMATIC MP 377 PRO ■ Technical specifications (continued) MP 377 PRO 15" Ambient conditions Mounting position maximum permissible angle of inclination without external ventilation 6AV6 644-2AB01-2AX0 vertical +/- 45 ° MP 377 PRO 15" 6AV6 644-2AB01-2AX0 Functionality under WinCC (TIA Portal) (continued) Lists • Number of text lists per project • Number of graphics lists per project 500 500 Operating temperature • Operation 0 °C to +45 °C Storage/transport temperature • Transport, storage -20 °C to +60 °C Relative humidity • max. relative humidity 85 % Archiving • Number of archives per device • Number of measuring points per project • Number of entries per archive • external evaluation Operating systems Operating system Windows CE • Size of archive WinCC flexible Standard Version 2008 or higher (to be ordered separately) Security • Number of user groups • Number of user rights • Password export/import 50 32 Yes Data carrier support • CF card Yes Configuration Configuration software • Configuration tool Languages Online languages • Number of online/runtime languages 5 Logging through printer • Recording/Printing Functionality under WinCC (TIA Portal) Libraries Yes Task planner Yes With alarm logging system (incl. buffer and acknowledgment) • Number of messages • Bit messages • Analog messages 4 000 Yes Yes Recipes • Number of recipes • Data records per recipe • Entries per data record • Recipe memory Variables • Number of variables per device Process coupling • Connection to controller • Limit values • Multiplexing Images • Number of configurable images 500 Image objects • Text objects • Graphics object 30000 text elements Bit maps, icons, vector graphics 50 000 Readable, e.g. with MS Excel, MS Access, etc. depending on free memory on ext. card/stick or on free hard disk space via network drive Alarms, report (shift report), color print, hardcopy MPI/PROFIBUS DP, serial, USB, Ethernet, by means of external storage medium, automatic transfer recognition • S7-1200 • S7-1500 S5, S7-200, S7-300/400, TI 505, Win AC, PC (TCP/IP), SINUMERIK, SIMOTION, Allen Bradley (DF1), Allen Bradley (DF485), Mitsubishi (FX), OMRON (LINK/Multilink), Modicon (Modbus), further non-Siemens drivers, see chapter "System interfaces" Yes Yes Expandability/openness • Open Platform Program Yes I/O I/O devices • Multi Media Card Printer, card reader, barcode reader Yes Dimensions Front of enclosure (W x H) 400 mm x 310 mm Weight Weight 7.25 kg 500 1 000 1 000 128 KB integrated Flash, expandable 4 096; Configuration with WinCC flexible 2008 and higher Yes Yes Complex image objects • Status/control • dynamic objects Transfer (upload/download) • Transfer of configuration 50 50 With SIMATIC S7 Diagrams, bar graphs, sliders, analog display, invisible buttons Siemens ST 80 / ST PC · 2013 3/5 3 © Siemens AG 2013 HMI devices for special requirements Fully enclosed HMI devices SIMATIC MP 377 PRO ■ Ordering data ■ More information Order No. SIMATIC MP 377 PRO 15" Touch Additional information is available on the Internet at: 6AV6644-2AB01-2AX0 15" color TFT display, 12 MB configuration memory, can be configured from WinCC Comfort (TIA Portal) or from WinCC flexible 2008 http://www.siemens.com/ip65-hmi-devices Note: Note: An adapter plate is required for mounting on the support arm systems of well-known manufacturers; see "Accessories for fully enclosed HMI devices". ■ Dimensional drawings All dimensions in mm. For installation cutout, see technical specifications. 3 310 400 SIMATIC MP 377 PRO 15" Touch 3/6 Siemens ST 80 / ST PC · 2013 G_ST80_XX_00351 67.85 98.5 Do you require a specific modification or extension to the products described here? Under "Customized products" you can find information about additional and generally available products for the sector, and about the possibilities for customized modification and adaptation. © Siemens AG 2013 HMI devices for special requirements Fully enclosed HMI devices SIMATIC HMI IPC477C PRO ■ Overview 3 SIMATIC HMI IPC477C PRO 19" SIMATIC HMI IPC477C PRO 19" (rear view) ■ Technical specifications HMI IPC477C PRO 6AV7 883-6….-…. 15" 6AV7 883-7….-…. 19" Supply voltage 24 V DC 24 V DC Processors Intel Celeron M 1.2 GHz, Intel Core2 Solo 1.2 GHz or Core2 Duo 1.2 GHz Intel Celeron M 1.2 GHz, Intel Core2 Solo 1.2 GHz or Core2 Duo 1.2 GHz Memory type DDR3-RAM DDR3-RAM Main memory 1 GB, 2 GB or 4 GB 1 GB, 2 GB or 4 GB free slots 1 x CF card slot 1 x CF card slot Operating system Windows Embedded Standard 2009, Windows Embedded Standard 7, Windows 7, or Windows XP Professional Multi Language Windows Embedded Standard 2009, Windows Embedded Standard 7, Windows 7, or Windows XP Professional Multi Language Additional OS information Language: EN/DE Language: EN/DE SIMATIC Software Optionally with pre-installed bundle software SIMATIC WinCC flexible 2008 or WinCC RT Advanced and/or SIMATIC WinAC RTX / RTX F 2010, SIMATIC WinCC or WinCC RT Professional as web client or standard client Optionally with pre-installed bundle software SIMATIC WinCC flexible 2008 or WinCC RT Advanced and/or SIMATIC WinAC RTX / RTX F 2010, SIMATIC WinCC or WinCC RT Professional as web client or standard client Floppy drive optional via external USB floppy drive optional via external USB floppy drive Optical drives possible as an external drive via USB possible as an external drive via USB Hard disk/mass storage CompactFlash drive with 4, 8, or 16 GB and/or 50 GB SSD (High Endurance) CompactFlash drive with 4, 8, or 16 GB and/or 50 GB SSD (High Endurance) General features Drives Siemens ST 80 / ST PC · 2013 3/7 © Siemens AG 2013 HMI devices for special requirements Fully enclosed HMI devices SIMATIC HMI IPC477C PRO ■ Technical specifications (continued) HMI IPC477C PRO 6AV7 883-6….-…. 15" 6AV7 883-7….-…. 19" Graphics interface DVI-I can be used for additional display unit (only VGA via adapter); 32-bit color depth, graphics memory up to 128 MB; resolution as for integrated display in each case DVI-I can be used for additional display unit (only VGA via adapter); 32-bit color depth, graphics memory up to 128 MB; resolution as for integrated display in each case Connection for keyboard/mouse USB / USB USB / USB serial interface COM1: 1 x V.24 (RS232) COM1: 1 x V.24 (RS232) PROFIBUS/MPI Optionally onboard, isolated, max. 12 Mbit/s, no plug-in card required, CP5611-compatible, not upgradable Optionally onboard, isolated, max. 12 Mbit/s, no plug-in card required, CP5611-compatible, not upgradable PROFINET (RT/IRT) Optional: 3 x RJ45, CP1616-compatible; not for retrofitting Optional: 3 x RJ45, CP1616-compatible; not for retrofitting USB 4 x on rear, USB 2.0 (500 mA) 4 x on rear, USB 2.0 (500 mA) PROFINET (IE), Ethernet onboard, 2 x 10/100/1000 Mbit (RJ45 without/with PROFIBUS), 1 x 10/100/1000 Mbit (RJ45 with PROFINET), no plug-in card necessary onboard, 2 x 10/100/1000 Mbit (RJ45 without/with PROFIBUS), 1 x 10/100/1000 Mbit (RJ45 with PROFINET), no plug-in card necessary Multimedia No No Temperature Yes Yes Watchdog Yes Yes DiagBit (similar to S.M.A.R.T.) Yes (for CF cards and SSD) Yes (for CF cards and SSD) Status LEDs Yes Yes Front side according to EN 60529 IP65 all-round to EN 60529 and NEMA4 IP65 all-round to EN 60529 and NEMA4 Vibration load during operation Tested according to DIN IEC 60068-2-6: 10 to 58 Hz: 0.075 mm, 58 to 200 Hz: 9.8 m/s² (1 g) Tested according to DIN IEC 60068-2-6: 10 to 58 Hz: 0.075 mm, 58 to 200 Hz: 9.8 m/s² (1 g) Shock loading during operation Tested according to DIN IEC 60068-2-7: 50 m/s² (5 g), 30 ms, 100 shocks Tested according to DIN IEC 60068-2-7: 50 m/s² (5 g), 30 ms, 100 shocks Relative humidity Tested according to DIN IEC 68-78, DIN IEC 60068-2-30: 5 % to 80 % at 25 °C (no condensation) Tested according to DIN IEC 68-78, DIN IEC 60068-2-30: 5 % to 80 % at 25 °C (no condensation) maximum permissible installation angle +/- +/- 45° from the vertical +/- 45° from the vertical Ambient temperature 0°C to 45 °C 0°C to 40°C Approvals CE, cULus(508) CE, cULus(508) EMC CE, 55022A, EN 61000-6-4, EN 61000-6-2 CE, 55022A, EN 61000-6-4, EN 61000-6-2 Degree of protection Overall device IP65/enclosure type 4x/type 12 (indoor use only) Overall device IP65/enclosure type 4x/type 12 (indoor use only) Dimensions 400 mm x 310 mm x 98 mm 483 mm x 400 mm x 115 mm Weight 7.4 kg 10.9 kg 3/8 Siemens ST 80 / ST PC · 2013 Interfaces 3 Monitoring functions Ambient conditions Certifications & standards © Siemens AG 2013 HMI devices for special requirements Fully enclosed HMI devices SIMATIC HMI IPC477C PRO ■ Ordering data Order No. Order No. IPC477C PRO as "Built to Order" versions (max. delivery time is 15 working days and with identified repair). SIMATIC HMI IPC477C PRO optionally with WinAC / WinCC flexible 6AV7883- 7 A 7 7 7 - 7 7 7 0 Embedded and fan-free, with IP65 housing with all-round protection; 5 x USB (500 mA), 1 of which on the front 24 V DC power supply with On/Off switch Front panels • 15" TFT Touch (IP65 enclosure) • 19" TFT Touch (IP65 enclosure) Processors and fieldbus • Celeron M 1.2 GHz, 2 x PROFINET (IE) • Celeron M 1.2 GHz, 2 x PROFINET (IE), 1 x PROFIBUS DP 12 • Core2 Solo 1.2 GHz, 2 x PROFINET (IE) • Core2 Solo 1.2 GHz, 2 x PROFINET (IE), 1 x PROFIBUS DP 12 • Core2 Solo 1.2 GHz, 1 x PROFINET (IE), 1 x PROFINET (3 ports) • Core2 Duo 1.2 GHz, 2 x PROFINET (IE) • Core2 Duo 1.2 GHz, 2 x PROFINET (IE), 1 x PROFIBUS DP 12 • Core2 Duo 1.2 GHz, 1 x PROFINET (IE), 1 x PROFINET (3 ports) Main memory (DDR3 RAM), 1 database • 1 GB • 2 GB • 4 GB Mass storage swappable (formatted with a partition) • None • CompactFlash 2 GB • CompactFlash 4 GB • CompactFlash 8 GB • CompactFlash 16 GB • 50 GB SSD (High Endurance) Mass storage (with Windows Embedded Standard 2009 (EN/DE) / Windows Embedded Standard 7 pre-installed and optionally with SIMATIC software) • CompactFlash 2 GB (only with Windows Embedded Standard 2009) • CompactFlash 4 GB • CompactFlash 8 GB • CompactFlash 16 GB • 50 GB SSD (High Endurance) SIMATIC HMI IPC477C PRO optionally with WinAC / WinCC flexible (continued) 6AV7883- 7 A 7 7 7 - 7 7 7 0 Operating system (pre-installed and activated) • Windows Embedded Standard 2009 • Windows XP Professional Multi-Language, only with SSD; without SIMATIC software • Windows Embedded Standard 7 SP1, pre-installed on internal drive, CF > 4 GB, SSD, and 2 GB main memory • Windows 7 Ultimate, MUI (Eng, Ger, Fr, It, Sp) pre-installed on SSD 6 7 A B BA DA E A GA Software packages WinAC / WinCC flexible CF 4 GB or more and SSD, only together with Windows Embedded Standard 2009 or Windows Embedded Standard 7 • With WinAC RTX pre-installed and configured for PROFIBUS and with WinCC flexible 2008 RT (incl. Archives/Recipes) pre-installed and configured - Number of tags 128 PT - Number of tags 512 PT - Number of tags 2048 PT - Number of tags 4096 PT D E F G H J • With WinAC RTX and WinCC flexible 2008 RT (incl. Archives/Recipes) pre-installed and configured - Number of tags 128 PT - Number of tags 512 PT - Number of tags 2048 PT - Number of tags 4096 PT • With WinAC RTX F pre-installed and configured for PROFIBUS DP 12 - Number of tags 128 PT 1 2 3 0 2 3 4 5 6 • With WinAC RTX F and WinCC flexible 2008 RT (incl. Archives/Recipes), pre-installed and configured - Number of tags 512 PT - Number of tags 2048 PT - Number of tags 4096 PT B C D E F K L M N P R S T U 2 3 4 5 6 Siemens ST 80 / ST PC · 2013 3/9 3 © Siemens AG 2013 HMI devices for special requirements Fully enclosed HMI devices SIMATIC HMI IPC477C PRO ■ Ordering data SIMATIC HMI IPC477C PRO optionally with WinAC / WinCC RT Advanced Order No. 6AV7883- Order No. 7A777-777 1 Embedded and fan-free, with IP65 housing with all-round protection; 5 x USB (500 mA), 1 of which on the front 24 V DC power supply with On/Off switch Front panels • 15" TFT Touch (IP65 enclosure) • 19" TFT Touch (IP65 enclosure) 3 Processors and fieldbus • Celeron M 1.2 GHz, 2 x PROFINET (IE) • Celeron M 1.2 GHz, 2 x PROFINET (IE), 1 x PROFIBUS DP 12 • Core2 Solo 1.2 GHz, 2 x PROFINET (IE) • Core2 Solo 1.2 GHz, 2 x PROFINET (IE), 1 x PROFIBUS DP 12 • Core2 Solo 1.2 GHz, 1 x PROFINET (IE), 1 x PROFINET (3 ports) • Core2 Duo 1.2 GHz, 2 x PROFINET (IE) • Core2 Duo 1.2 GHz, 2 x PROFINET (IE), 1 x PROFIBUS DP 12 • Core2 Duo 1.2 GHz, 1 x PROFINET (IE), 1 x PROFINET (3 ports) Main memory (DDR3 RAM),1 database • 2 GB • 4 GB Mass storage, removable • None • CompactFlash 2 GB (only with Windows Embedded Standard 2009) • CompactFlash 4 GB • CompactFlash 8 GB • CompactFlash 16 GB • 50 GB SSD (High Endurance) Mass storage, installed (Windows Embedded Standard 7 pre-installed and optionally with SIMATIC software) • CompactFlash 4 GB • CompactFlash 8 GB • CompactFlash 16 GB • 50 GB SSD (High Endurance) SIMATIC HMI IPC477C PRO optionally with WinAC / WinCC RT Advanced (continued) Operating system (pre-installed and activated) • Windows Embedded Standard 7, pre-installed on internal drive 6AV7883- 7A777-777 1 E A Software packages WinAC / WinCC RT Advanced • With WinAC RTX pre-installed and configured for PROFIBUS and with WinCC RT Advanced (incl. Logging & Recipes) pre-installed and configured - Number of tags 128 PT - Number of tags 512 PT - Number of tags 2048 PT - Number of tags 4096 PT 6 7 A B D • With WinAC RTX and WinCC RT Advanced (incl. Logging & Recipes) pre-installed and configured - Number of tags 128 PT - Number of tags 512 PT - Number of tags 2048 PT - Number of tags 4096 PT • With WinAC RTX F pre-installed and configured for PROFIBUS DP 12 E F G H J • With WinAC RTX F and WinCC RT Advanced (incl. Logging & Recipes) pre-installed and configured - Number of tags 128 PT - Number of tags 512 PT - Number of tags 2048 PT - Number of tags 4096 PT 2 3 B C D E F K L M N P R S T U 0 2 3 4 5 6 3 4 5 6 Note: An adapter plate is required for mounting on the support arm systems of well-known manufacturers; see "Accessories for fully enclosed HMI devices". For further bundles with SIMATIC HMI IPC477C PRO with SIMATIC WinCC V7.0 and SIMATIC WinCC RT Professional (TIA Portal), see under SIMATIC HMI IPC477C bundles 3/10 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 HMI devices for special requirements Fully enclosed HMI devices SIMATIC HMI IPC477C PRO ■ Dimensional drawings 400 348.7 All dimensions in mm. For installation cutout, see technical specifications. SIMATIC HMI IPC477C PRO 15" Touch version 81.85 78.85 119 482.7 G_ST80_XX_00401 400 G_ST80_XX_00400 105 3 SIMATIC HMI IPC477C PRO 19" Touch version ■ More information Additional information is available on the Internet at: Note: http://www.siemens.com/ip65-hmi-devices Do you require a specific modification or extension to the products described here? Under "Customized products" you can find information about additional and generally available products for the sector, and about the possibilities for customized modification and adaptation. Siemens ST 80 / ST PC · 2013 3/11 © Siemens AG 2013 HMI devices for special requirements Fully enclosed HMI devices SIMATIC Flat Panel PRO ■ Overview 3 SIMATIC Flat Panel Monitor PRO 19" SIMATIC Flat Panel Monitor PRO 15" with expansion unit (rear view) ■ Technical specifications Flat Panel PRO 15" PRO 19" Supply voltage Supply voltage 24 V DC and 230 V AC combined 24 V DC and 230 V AC combined permissible frequency range 47 to 63 Hz 47 to 63 Hz Power consumption, max. 35 VA 35 VA General features Can be separate from the computer Flat Panel PRO 15" PRO 19" Certification cULus (UL 508), NEMA4-tested cULus (UL 508), NEMA4-tested EMC CE EN 55011 class A CE EN 55011 class A CE mark Yes Yes UL approval Yes Yes Certifications & standards up to 30 m up to 30 m Display Standards, approvals, certificates Ambient conditions On-screen display (OSD) configuration Yes Yes Display version 15" TFT 19" TFT visible area (H x W) in mm 304 x 228 376 x 301 Viewing angle 140° x 120° (min) 140° x 120° (min) Pixel pitch 0.297 mm x 0.297 mm 0.297 mm x 0.297 mm Inclination angle Resolution (W x H in pixels) 1024 x 768 1280 x 1024 Interfaces Refresh rate 60 to 75 Hz 60 to 75 Hz Line frequency 46.7 - 80 kHz 46.7 - 80 kHz Brightness/contrast > 260 cd/m2 / 350:1 > 300 cd/m2 / 300:1 Number of colors 16.7 million 16.7 million MTBF of backlit display (at 25 °C, 24 hours continuous operation) 50,000 h 50,000 h Touch screen analog-resistive analog-resistive 1 g (10 m/s²) 1 g (10 m/s²) 5 g (50 m/s²) 5 g (50 m/s²) Temperature • Ambient temperature during operation 5 to +45 °C 5 to +45 °C +/- 45° from the vertical +/- 45° from the vertical Graphics interface Standard VGA interface 15-pin sub-D/digital DVI-D interface Standard VGA interface 15-pin sub-D/digital DVI-D interface Interface for Touch USB (V1.1) USB (V1.1) USB interface for touch screen Yes Yes 400 mm x 310 mm x 91 mm 483 mm x 400 mm x 105 mm Connection for keyboard/mouse/ barcode reader Yes, via USB Yes, via USB Degree of protection Overall device IP65/enclosure type 4x/type 12 (indoor use only) Overall device IP65/enclosure type 4x/type 12 (indoor use only) 6.7 kg 10 kg Mounting Dimensions External dimensions (W x H x D) Type of operation 3/12 Vibration load during operation Shock loading during operation Siemens ST 80 / ST PC · 2013 Weight Weight © Siemens AG 2013 HMI devices for special requirements Fully enclosed HMI devices SIMATIC Flat Panel PRO ■ Ordering data ■ More information Order No. SIMATIC Flat Panel PRO 15" Touch 6AV7861-5TB10-1BA0 SIMATIC Flat Panel PRO 19" Touch 6AV7861-6TB10-1BA0 Additional information is available on the Internet at: http://www.siemens.com/ip65-hmi-devices Note: Note: An adapter plate is required for mounting on the support arm systems of well-known manufacturers; see "Accessories for fully enclosed HMI devices". Do you require a specific modification or extension to the products described here? Under "Customized products" you can find information about additional and generally available products for the sector, and about the possibilities for customized modification and adaptation. ■ Dimensional drawings All dimensions in mm. For installation cutout, see technical specifications. 400 310 3 67.85 G_ST80_XX_00350 90.85 SIMATIC Flat Panel PRO 15" Touch 483 400 SIMATIC FLAT PANEL G_ST80_XX_00371 82 105 SIMATIC Flat Panel PRO 19" Touch Siemens ST 80 / ST PC · 2013 3/13 © Siemens AG 2013 HMI devices for special requirements Fully enclosed HMI devices SIMATIC Thin Client PRO ■ Overview ■ Technical specifications Thin Client PRO 15" Touch 15.1" Display type TFT, 65536 colors Resolution (pixels) • Resolution (WxH in pixel) 1024 x 768 Backlighting • MTBF backlighting (at 25 °C) about 50000 hours Control elements Control elements Touch screen Connection for mouse/keyboard/ barcode reader 3 SIMATIC Thin Client PRO 15" Analog, resistive Supply voltage Supply voltage 24 V DC Processor Processor ARM, 266 MHz Memory Type Flash / RAM Usable memory for user data No info Interfaces Interfaces 1 x Ethernet (RJ45) USB port 1 x USB Industrial Ethernet • Industrial Ethernet interface 1 x Ethernet (RJ45) Protocols WEB characteristics • HTTP • HTML • CSS Yes Yes Yes Protocols (terminal link) • Sm@rtServer • RDP Yes Yes Degree and class of protection Front Rear Standards, approvals, certificates Certifications Siemens ST 80 / ST PC · 2013 USB / USB Touch operation • Touch screen EMC Emission of radio interference acc. to EN 55 011 • Emission of radio interferences acc. to EN 55 011 (limit class A) 3/14 6AV6646-2AB21-2AX0 Display Size Yes; EN 61000-6-4, interference emission: Intended for use in industrial areas. IP65, NEMA 4x, NEMA 12 (when installed) IP65 CE, cULus, C-TICK, NEMA 4x (Enclosure Type 4X, Type 12), NEMA 12 EMC The product is designed for use in industrial environments. When used in residential areas, the emission of radio interference according to limit class B of EN 55011 must be ensured. For further information please refer to the user documentation. Suitable for safety functions No © Siemens AG 2013 HMI devices for special requirements Fully enclosed HMI devices SIMATIC Thin Client PRO ■ Technical specifications (continued) 400 0 °C to +45 °C Storage/transport temperature • Transport, storage -20 °C to +60 °C Relative humidity • max. relative humidity 85 %; (Storage) Dimensions Front of enclosure (W x H) 400 mm x 310 mm Weight Weight 6.5 kg SIMATIC Thin Client PRO 15" Touch All dimensions in mm. For installation cutout, see technical specifications. +/- 45 ° Operating temperature • Operation ■ Ordering data ■ Dimensional drawings 3 Order No. 6AV6646-2AB21-2AX0 90.85 SIMATIC Thin Client with Sm@rtAccess • Touch device 15" PRO with Sm@rtAccess license (panels) • Touch device 15" PRO with Sm@rtAccess license for WinCC flexible 2008 Runtime 67.85 Starter packages 6AV6653-6CA01-2AA0 6AV6653-6FA01-2AA0 Note: An adapter plate is required for mounting on the support arm systems of well-known manufacturers; see "Accessories for fully enclosed HMI devices". G_ST80_XX_00350 Ambient conditions maximum permissible angle of inclination without external ventilation 6AV6646-2AB21-2AX0 310 Thin Client PRO 15" Touch SIMATIC Thin Client PRO 15" Touch ■ More information Additional information is available on the Internet at: http://www.siemens.com/ip65-hmi-devices Note: Do you require a specific modification or extension to the products described here? Under "Customized products" you can find information about additional and generally available products for the sector, and about the possibilities for customized modification and adaptation. Siemens ST 80 / ST PC · 2013 3/15 © Siemens AG 2013 HMI devices for special requirements Accessories for fully enclosed HMI devices Adapter sets ■ Overview ■ More information Adapter sets • The adapter sets are required for connecting the SIMATIC HMI PRO device with the support arm head of the respective support arm system • By directly connecting the support arm head to the device, there is complete flexibility in the choice of support arm components • Adapter sets are available for the VESA 75 and VESA 100 systems. • Further adapter sets can be obtained directly from the respective supporting bracket manufacturer: Bernstein, Rittal, Rose and Haseke ■ Ordering data 3 Order No. VESA 100 adapter set 1) for • VESA 100 • Rose GTN II 6AV7674-0KD00-0AA0 Adapter set VESA 75 for • VESA 75 6AV7674-0KE00-0AA0 Replacement basic adapter, suitable for SIMATIC HMI PRO devices 6AV7674-0KA00-0AA0 1) The VESA 100 adapter set cannot be used in combination with the 19" Flat Panel PRO. Note: The internal diameter of the 48 mm supporting bracket tubes is not suitable for passage of the standard DVI-D cable. Scope of delivery: • One basic adapter or one adapter plate • Mounting hardware 3/16 Siemens ST 80 / ST PC · 2013 Additional information is available on the Internet at: http://www.siemens.com/ip65-hmi-devices Note: Do you require a specific modification to or option for the products described here? Under "Customized products" you can find information about additional and generally available products for the sector, and about the possibilities for customized modification and adaptation. © Siemens AG 2013 HMI devices for special requirements Accessories for fully enclosed HMI devices Extension units ■ Overview ■ Ordering data Order No. Extension Unit 15" 6AV7674-0KG00-0AA0 For mounting on all 15" PRO devices Extension units With the extension units, the range of possible on-site operations can be extended. They are mounted on the SIMATIC HMI PRO device and can be equipped individually, e.g. with Key Panel (KP8), 3SB elements, emergency stop buttons, key switches, RFID reader, etc. • They can be mounted on the left or right side of the PRO device, as required • Direct installation of up to 2 Key Panels KP8 / KP8F • IP65 - cable routing • Can be equipped individually • For all 15"/19" PRO devices The combination of HMI PRO device and KP8 PN offers the following advantages: • No control cabinet required • Low cabling overhead • Optimally coordinated design Extension Unit 15" KP8 For mounting on all 15" PRO devices for direct installation of up to 2 KP8 / KP8F 6AV7674-0KG01-0AA0 Starter package Extension Unit 15" with KP8 1 x Extension Unit 15" KP8, 1 x Key Panel 8 PN, 1 x blank front 6AV7674-0KG11-0AA0 Extension Unit 19" right • For support arm mounting from above Mounting of the Extension Unit on the right side of the 19" PRO device • For support arm mounting from below Mounting of the Extension Unit on the left side of the 19" PRO device 6AV7674-0KJ00-0AA0 Extension Unit 19" KP8 right • For support arm mounting from above Mounting of the Extension Unit on the right side of the 19" PRO device • For support arm mounting from below Mounting of the Extension Unit on the left side of the 19" PRO device • For direct installation of up to 2 KP8 / KP8F 6AV7674-0KJ01-0AA0 Starter package Extension Unit 19" with KP8 right 1 x Extension Unit 19" KP8 right, 1 x Key Panel 8 PN, 1 x blank front 6AV7674-0KJ11-0AA0 Extension Unit 19" left • For support arm mounting from above Mounting of the Extension Unit on the left side of the 19" PRO device • For support arm mounting from below Mounting of the Extension Unit on the right side of the 19" PRO device 6AV7674-0KH00-0AA0 Starter package Extension Unit 19" with KP8 left 1 x Extension Unit 19" KP8 left, 1 x Key Panel 8 PN, 1 x blank front 6AV7674-0KH11-0AA0 Extension Unit 19" KP8 left • For support arm mounting from above Mounting of the Extension Unit on the left side of the 19" PRO device • For support arm mounting from below Mounting of the Extension Unit on the right side of the 19" PRO device • For direct installation of up to 2 KP8 / KP8F 6AV7674-0KH01-0AA0 3 Siemens ST 80 / ST PC · 2013 3/17 © Siemens AG 2013 HMI devices for special requirements Accessories for fully enclosed HMI devices Extension units ■ Ordering data 3 Order No. KP8 front plate for the Extension Unit • For installing up to two KP8 in an Extension Unit • Suitable for all 15" and 19" Extension Units 6AV7674-0KH30-0AB0 Empty front KP8 design in combination with front panel KP8 6AV3688-3XY38-3AX0 Spare front plate for the Extension Unit • Suitable for all 15" and 19" Extension Units • Required if the front plate supplied with the Extension Unit must be replaced 6AV7674-0KH30-0AA0 Additional information is available on the Internet at: http://www.siemens.com/ip65-hmi-devices Note: Scope of delivery: • 1 Extension Unit box • 1 front plate for the Extension Unit • 1 connecting tube • Mounting accessories 3/18 ■ More information Siemens ST 80 / ST PC · 2013 Do you require a specific modification to or option for the products described here? Under "Customized products" you can find information about additional and generally available products for the sector, and about the possibilities for customized modification and adaptation. © Siemens AG 2013 HMI devices for special requirements Accessories for fully enclosed HMI devices IP65 keyboards ■ Overview ■ More information IP65 keyboards Additional information is available on the Internet at: With the stainless steel IP65 keyboards, the range of possible on-site operations can be extended. They are mounted on the SIMATIC HMI PRO device underneath the base adapter, and they are available in two versions. • Anti-twist and non-removable stainless steel key caps • Abrasion-resistant laser labeling (depth engraving with annealing marking) • Secure, pleasant key feel • Maximum user-friendliness thanks to withdrawable long-stroke key • Windows layout (EN/US) with two additional keys (left and right mouse key function) via cursor block • USB interface • Angle-adjustable connection for optimal ergonomics • Water and dust protection in accordance with degree of protection IP65 • For all 15"/19" PRO devices http://www.siemens.com/ip65-hmi-devices ■ Ordering data Note: Do you require a specific modification to or option for the products described here? Under "Customized products" you can find information about additional and generally available products for the sector, and about the possibilities for customized modification and adaptation. 3 Order No. Stainless steel IP65 keyboard 15" • Width: 400 mm (adapted to 15" SIMATIC HMI PRO) • Windows layout (EN/US) without NUM block • Angle-adjustable adapter 6AV7674-0NC00-0AA0 Stainless steel IP65 keyboard 19" • Width: 483 mm (adapted to 19" SIMATIC HMI PRO) • Windows layout (EN/US) with NUM block • Angle-adjustable adapter 6AV7674-0NE00-0AA0 Tool and keyboard tray • Width: 483 mm (adapted to 19" SIMATIC HMI PRO) • Including 2-port USB interface • Angle-adjustable adapter 6AV7674-0NE01-0AA0 Scope of delivery: • One stainless steel IP65 keyboard incl. mounting adapter for PRO devices • Mounting accessories Siemens ST 80 / ST PC · 2013 3/19 © Siemens AG 2013 HMI devices for special requirements Accessories for fully enclosed HMI devices USB interfaces ■ Overview ■ More information • The USB interface is used for connecting external peripheral devices to the MP 377 PRO, the HMI IPC477C PRO, the Flat Panels PRO, and the Thin Client PRO. • USB peripheral devices can thus be connected and operated without opening the device • Extension of the internal USB interface externally ■ Ordering data 1-port USB interface Order No. 6AV7674-0LX00-0AA0 For fully enclosed HMI devices, length USB cable: 0.5 m 2-port USB interface 3 6AV7674-0LX01-0AA0 For fully enclosed HMI devices, length USB cable: 0.5 m. Not suitable for: Thin Client, MP 377, and Flat Panel 3/20 Siemens ST 80 / ST PC · 2013 Additional information is available on the Internet at: http://www.siemens.com/ip65-hmi-devices Note: Do you require a specific modification to or option for the products described here? Under "Customized products" you can find information about additional and generally available products for the sector, and about the possibilities for customized modification and adaptation. © Siemens AG 2013 HMI devices for special requirements Devices with stainless steel front Devices with stainless steel front ■ Overview For special requirements, the following HMI devices with stainless steel front (DIN EN 1672-2), e.g. for use in the food, beverages and tobacco industries, are offered. SIMATIC HMI IPC677C INOX PC platform with high degree of industrial compatibility for demanding tasks in the area of PC-based automation. Note: Do you require a specific modification to or option for the products described here? Then look up "Customized products", where you will find information about additional generallyavailable industry-specific products that can be ordered, as well as about options for customer-specific modifications and adaptations. Rugged construction: The PC is resistant to the harshest mechanical stress and is reliable in operation. • Compact design • High degree of investment protection • Fast integration capability • 15" TFT Touch, stainless steel/INOX • All interfaces such as PROFIBUS or PROFINET onboard 3 More SIMATIC HMI INOX panels You will find further INOX industry products, as well as customerspecific product variants, in the "Customized Automation" section, e.g. • SIMATIC HMI Flat Panel 15" Touch INOX • SIMATIC HMI Flat Panel 19" Touch INOX • SIMATIC HMI Flat Panel 19" Touch INOX fully enclosed Siemens ST 80 / ST PC · 2013 3/21 © Siemens AG 2013 HMI devices for special requirements Devices with stainless steel front SIMATIC HMI IPC677C INOX ■ Overview ■ Technical specifications HMI IPC677C INOX 15" Touch 6AV789... General features Front panel 15" TFT Touch Display Screen diagonal 15" Resolution (W x H in pixels) 1024 x 768 MTBF of backlighting (at 25 °C) 50 000 h at 24 h continuous operation, temperature-dependent Type of operation Touch screen Yes Design Central design Yes Dimensions 3 PC platform with high degree of industrial compatibility for demanding tasks in the area of PC-based automation. Rugged design: The PC is resistant to the harshest mechanical stress and is reliable in operation. • Compact design • High degree of investment protection • Fast integration capability • Front panel versions: - 15" TFT Touch, stainless steel/INOX 3/22 Siemens ST 80 / ST PC · 2013 Installation cutout/device depth (W x H x D) in mm 450 x 290 x 142 (incl. optical drive) Mounting dimensions in centralized configuration (W x H x D, without optical drive) in mm 450 x 290 x 121 Additional mounting depth (optical drive) in mm 21 Weight HMI IPC in a centralized configuration approx. 14 kg © Siemens AG 2013 HMI devices for special requirements Devices with stainless steel front SIMATIC HMI IPC677C INOX ■ Ordering data SIMATIC HMI IPC677C INOX Front panels • 15" TFT Touch Front options • INOX front, without front USB, with 15" TFT Touch only Power supply • 24 V DC • 110/230 V AC, power cable for Europe • 110/230 V AC, without power cable • 110/230 V AC, power cable for UK • 110/230 V AC, power cable for CH • 110/230 V AC, power cable for the USA • 110/230 V AC, power cable for Italy • 110/230 V AC, power cable for China Processor • Intel Celeron 1.86 GHz (2 MB shared cache), 2 cores • Intel Celeron 1.86 GHz (2 MB shared cache), 2 cores, PROFIBUS MPI, 2 MB buffered SRAM • Intel Celeron 1.86 GHz (2 MB shared cache), 2 cores, PROFINET (3x RJ45, CP1616-compatible), 2 MB buffered SRAM • Intel Core i3, 2.13 GHz (3 MB shared cache), 2 cores, hyper-threading • Intel Core i3, 2.13 GHz (3 MB shared cache), 2 cores, hyper-threading, PROFIBUS MPI, 2 MB buffered SRAM • Intel Core i3, 2.13 GHz (3 MB shared cache), 2 cores, hyper-threading, PROFINET (3x RJ45, CP1616-compatible), 2 MB buffered SRAM • Intel Core i7, 2.53 GHz (4 MB shared cache), 2 cores, hyper-threading, turbo boost • Intel Core i7, 2.53 GHz (4 MB shared cache), 2 cores, hyper-threading, turbo boost, PROFIBUS MPI, 2 MB buffered SRAM • Intel Core i7, 2.53 GHz (4 MB shared cache), 2 cores, hyper-threading, turbo boost, PROFINET (3 x RJ45, CP 1616-compatible), 2 MB buffered SRAM Order No. Order No. 6AV789 7 - 7 7 7 7 7 - 7 7 7 7 6AV789 7 - 7 7 7 7 7 - 7 7 7 7 SIMATIC HMI IPC677C INOX (continued) Main memory • 1 GB DDR3 • 2 GB DDR3 • 3 GB DDR3 • 4 GB DDR3 • 8 GB DDR3 • 2 GB DDR3 with ECC • 4 GB DDR3 with ECC • 8 GB DDR3 with ECC 2 2 A B C D E F G H A B C D E F G H J 0 1 2 3 4 5 6 7 Mass storage • 250 GB SATA hard disk • 500 GB SATA hard disk • RAID1 dual hard disk module 2 x 250 GB SATA, preconfigured • Dual hard disk module 2 x 250 GB SATA • 50 GB SSD (SLC) • Second CF card slot (only in combination with Windows XP embedded), internal, empty, only with version without opt. drive and without HDD • Without mass storage Optical drives • None • DVD±RW±R combo drive 0 1 2 3 3 4 5 8 0 1 Communication Interfaces • 2 x PCI available • 1 x PCI, 1 x PCIe (x16) available A B Operating system (pre-installed and activated) • Without operating system • Windows XP Professional Multi-Language 1) • Windows 7 Ultimate 32-bit Multi-Language 1) • Windows Embedded Standard on 8 GB CF card 2) • Windows 7 Ultimate 64-Bit Multi-Language 1) A B C D E Software expansion • None • SIMATIC IPC DiagMonitor V4.3 enclosed • SIMATIC IPC Image & Partition Creator V3.2 enclosed • SIMATIC IPC DiagMonitor V4.3, Image & Partition Creator V3.2 enclosed 0 1 2 3 1) Multi-language means: D/E/F/I/SP/CHIN traditional/CHIN simplified/ Korean/Japanese 2) Without RAID 1 option only Siemens ST 80 / ST PC · 2013 3/23 © Siemens AG 2013 HMI devices for special requirements Devices with stainless steel front SIMATIC HMI IPC677C INOX ■ Ordering data Order No. Non-heating apparatus cable for SIMATIC Box and Panel PC SIMATIC PC power cable, 230 V AC, angled, 3 m, for: • Germany • United Kingdom • Switzerland • USA • Italy • China 6ES7900-1AA00-0XA0 6ES7900-1BA00-0XA0 6ES7900-1CA00-0XA0 6ES7900-1DA00-0XA0 6ES7900-1EA00-0XA0 6ES7900-1FA00-0XA0 Touch pen Captive pen for operation of the touch devices, mounting of the support on the control cabinet 6AV7672-1JB00-0AA0 Expansion components From page 5/153 Communication components From page 5/186 M H 6ES7648-2AJ40-0KA0 6ES7648-2AJ50-0KA0 6ES7648-2AJ60-0KA0 6ES7648-2AJ40-1KA0 6ES7648-2AJ50-1KA0 6ES7648-2AJ60-1KA0 G Memory expansion • 1 GB DDR3 DIMM • 2 GB DDR3 DIMM • 4 GB DDR3 DIMM • 1 GB DDR3 DIMM with ECC • 2 GB DDR3 DIMM with ECC • 4 GB DDR3 DIMM with ECC J K K G_ST80_XX_00288 3 ■ Dimensional drawings All dimensions in mm. Accessories L N Panel PC 677C INOX 15" Touch Control units PC 677 INOX G H J K L M N 289 271 138 11 24 367 42 Touch devices 15" ■ More information Additional information is available in the Internet under: http://www.siemens.com/inox-hmi-devices Note: Do you require a specific modification or supplement to the products described here? Then refer to "Customized products", where you will find information about additional sector-specific products that can be ordered as well as about options for customer-specific modification and adaptation. 3/24 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 HMI devices for special requirements HMI devices for hazardous areas HMI devices for hazardous areas ■ Overview The SIMATIC HMI Ex devices are intrinsically-safe Panel PCs and Thin Clients which have been specially developed for hazardous areas. The intrinsically-safe design allows simple installation on site. The variety of certification allows use in many parts of the world without further approvals. Available as HMI devices for hazardous areas "Zone 1" and "Zone 2" are: • SIMATIC HMI Panel PC Ex • SIMATIC HMI Thin Client Ex The devices are fanless and permit completely maintenancefree installation without batteries or rotating parts. Further SIMATIC HMI devices are also available for the hazardous area "Zone 2/22" and can be found in the chapter "Operator panels": • SIMATIC HMI Comfort Panels 3 Siemens ST 80 / ST PC · 2013 3/25 © Siemens AG 2013 HMI devices for special requirements HMI devices for hazardous areas SIMATIC HMI Panel PC Ex ■ Overview SIMATIC HMI Panel PC Ex with international approvals for operation and monitoring in hazardous areas. 3 ■ Technical specifications HMI Panel PC Ex 6AV7200-1... HMI Panel PC Ex Design Panel PC built-in unit, protective enclosure available as an option Front 15" and 19", optional 15" sunlight-readable displays Operation Touch with 8 function keys Processor Intel Atom N270 with 1.6 GHz Main memory 1 GB DDR2 SDRAM, 2 GB optional Operating system, preinstalled and configured Windows XP Professional, Windows XP Embedded, Windows 7 MUI Mass storage CompactFlash 4 GB / 16 GB, hard disk 100 GB Power supply 24 V DC, max. 2.1 A (19") Devices in version "Zone 1" ATEX directive 94/9/EC • Network 10/100 Base-Tx • Network 10/100 Base-Fx IECEx • Network 10/100 Base-Tx • Network 10/100 Base-Fx Interfaces Ethernet 10/100 Mbit Ex e, or fiber-optics 100 Mbit (SC) Ex op is GOST-R • Network 10/100 Base-Tx USB 2.0 2 x Ex i, 2 x Ex e (Zone 1) or 2 x Ex nA (Zone 2) • Network 10/100 Base-Fx Serial 1 x RS232 or 1 x RS422/485 Ambient conditions Ex d e ia ib mb [ia ib] IIC T4 Gb Ex ia tb [ia ib] IIIC T80°C Db IP66 Ex d e ia ib mb [ia ib op is] IIC T4 Gb Ex ia tb [ia ib op is] IIIC T80°C Db IP66 2 Ex d e ia ib mb [iaib] IIC T4 DIP A21 TA80°C, IP66 2 Ex d e ia ib mb [iaibopis] IIC T4 DIP A21 TA80°C, IP66 Ex d e ia ib mb [ia ib] IIC T4 Gb, Type 4X, IP66 Class II, Division 1, Groups E, F, G, T80°C Ex ia tb [ia ib] IIIC T80°C Db, IP66 Ex d e ia ib mb [ia ib] IIC T4 Ex ia tb [ia ib] IIIC T80°C Db IP66 IP66 at front, IP65 at rear, IP66 in protective enclosure Ambient temperature during operation -20 °C ... +50 °C (cold start -10 °C) with optional additional heating down to -30 °C KGS Relative humidity during operation 90 % at + 40 °C, no condensation InMetro • Network 10/100 Base-Tx • Network 10/100 Base-Fx Device version "UL Class 1, Division 2" Siemens ST 80 / ST PC · 2013 II 2 (2) G Ex d e ia ib mb [ia ib] IIC T4 Gb II 2 (2) D Ex ia tb [ia ib] IIIC T80°C Db IP66 II 2 (2) G Ex d e ia ib mb [ia ib op is] IIC T4 Gb II 2 (2) D Ex ia tb [ia ib op is] IIIC T80°C Db IP66 CSA Degree of protection 3/26 6AV7200-1... Approvals/directives General features Ex d e ia ib mb [ia ib] IIC T4 Gb Ex ia tb [ia ib] IIIC T80°C Db IP66 Ex d e ia ib mb [ia ib op is] IIC T4 Gb Ex ia tb [ia ib op is] IIIC T80°C Db IP66 Class 1, Division 2, Groups A, B, C, D Class 2, Division 2, Groups F, G Class 3, Hazardous Locations © Siemens AG 2013 HMI devices for special requirements HMI devices for hazardous areas SIMATIC HMI Panel PC Ex ■ Technical specifications (continued) HMI Panel PC Ex 6AV7200-1... Devices in version "Zone 2" ATEX directive 94/9/EC • Network 10/100 Base-Tx • Network 10/100 Base-Fx IECEx • Network 10/100 Base-Tx • Network 10/100 Base-Fx GOST-R • Network 10/100 Base-Tx • Network 10/100 Base-Fx CSA InMetro • Network 10/100 Base-Tx • Network 10/100 Base-Fx Device version "UL Class 1, Division 2" HMI Panel PC Ex 6AV7200-1... Dimensions II 3 (2/3) G Ex d e ia ib mb nA [ib Gb] [ic] IIC T4 Gc II3 (2/3) D Ex ia tc [ib Db] [ic] IIIC T80°C Dc IP66 II 3 (2/3) G Ex d e ia ib mb nA [ib op is Gb] [ic] IIC T4 Gc II 3 (2/3) D Ex ia tc [ib op is Db] [ic] IIIC T80°C Dc IP66 Mounting dimensions (W x H x D) 15": 427.5 mm x 327.5 mm x 165 mm 19": 522.5 mm x 412.5 mm x 165 mm Front dimensions (W x H) 15": 440 mm x 340 mm 19": 535 mm x 425 mm Weight 15": 15 kg 19": 23 kg Ex d e ia ib mb nA [ib Gb] [ic] IIC T4 Gc Ex ia tc [ib Db] [ic] IIIC T80°C Dc IP66 Ex d e ia ib mb nA [ib op is Gb ] [ic] IIC T4 Gc Ex ia tc [ib op is Db] [ic] IIIC T80°C Dc IP66 3 2 Ex d e ia ib mb nA [ib][ic] IIC T4 DIP A21 TA80°C, IP66 2 Ex d e ia ib mb nA [ib opis][ic] IIC T4 DIP A21 TA80°C, IP66 Ex d e ia ib mb nA [ib Gb] [ic] IIC T4 Gc, Type 4X, IP66 Class II, Division 2, Groups E, F, G, T80°C; Ex ia tc [ib ic] IIIC T80°C Dc, IP66 Ex d e ia ib mb nA [ib Gb] [ic] IIC T4 Gc Ex ia tc [ib Db] [ic] IIIC T80°C Dc IP66 Ex d e ia ib mb nA [ib op is Gb] IIC T4 Ex ia tc [ib op is Db] [ic] IIIC T80°C Dc IP66 Class 1, Division 2, Groups A, B, C, D Class 2, Division 2, Groups F, G Class 3, Hazardous Locations Siemens ST 80 / ST PC · 2013 3/27 © Siemens AG 2013 HMI devices for special requirements HMI devices for hazardous areas SIMATIC HMI Panel PC Ex ■ Ordering data SIMATIC HMI Panel PC Ex 3 Order No. Order No. 6AV7200- 1 7 7 7 7 - 7 7 A 0 Design / display size • Zone 2: 15" Touch with function keys • Zone 2: 19" Touch with function keys • Zone 1: 15" Touch with function keys • Zone 1: 19" Touch with function keys • UL Class 1, Division 2: 15" Touch with function keys • UL Class 1, Division 2: 19" Touch with function keys • Zone 2: 15" Touch, sunlight readable with 8 function keys • Zone 1: 15" Touch, sunlight readable with 8 function keys Communication interfaces • 10/100 base Tx, Ex e • 100 base Fx FOC (SC), Ex op is Mass storage • CF 4 GB, 1 GB RAM • CF 16 GB, 1 GB RAM • HDD 100 GB, 1 GB RAM • CF 4 GB, 2 GB RAM • CF 16 GB, 2 GB RAM • HDD 100 GB, 2 GB RAM Operating system (preinstalled) • Windows XP Embedded on CF (language package 1) 1) • Windows XP Professional MUI (only on HDD) • Windows 7 Ultimate (only on HDD) Enclosure options (device is delivered already fitted) • without • Stainless steel enclosure for: - Wall mounting - Stand (incl. coupling, 300° rotation possible) - Suspension bracket (incl. coupling, 300° rotation possible) - Support arm (incl. coupling, 300° rotation possible) - Swivel arm from above (incl. coupling, 300° rotation possible) A B D E 1) G H J K A B 1 2 3 4 5 6 1 3 4 0 2 3 4 5 6 A B C D E F G -z -z -z -z A B C D 0 0 0 0 1 1 1 1 Package 1: upon initial startup, select the language from: English, German, French, Italian, Spanish, Portuguese, Brazilian, Dutch, Danish, Swedish, Norwegian, Finnish, Greek, Hungarian, Czech, Polish, Turkish, Russian, Hebrew, Arabic, Chinese, Japanese, Korean, Thai 3/28 Siemens ST 80 / ST PC · 2013 Digital KVM for HMI Thin Client Ex 6AV7675-0EX00-0AA0 USB drive • Intrinsically-safe, 8 GB • Intrinsically-safe, 8 GB with recovery function 6AV7675-0FX00-0AA0 6AV7675-0FX10-0AA0 Ethernet switch 6AV7675-0PX00-0AA0 with FOC 4 x 100 Base Tx, 1 x 100 Base (MTRJ) Fx Ex op is External keyboard for stainless steel enclosure (incl. keyboard enclosure) • without • QWERTZ keyboard • QWERTY keyboard • AZERTY keyboard • QWERTZ keyboard with trackball • QWERTY keyboard with trackball • AZERTY keyboard with trackball Further options together with stainless steel enclosure • Breather glands • Heating (requires breather glands) • Handles • Front USB (at bottom) Accessories © Siemens AG 2013 HMI devices for special requirements HMI devices for hazardous areas SIMATIC HMI Panel PC Ex ■ Dimensional drawings Legend: i = Clamping frame h = Mounting clamp (10 x) j = Control cabinet or enclosure All dimensions in mm. For mounting cut-out see technical specifications. 3 h 426 i 427.5+0.5 j G_ST80_XX_00419 340 327.5+0.5 165 326 440 SIMATIC HMI Panel PC Ex 15" h 521 522.5+0.5 i j G_ST80_XX_00420 412.5+0.5 165 411 425 535 SIMATIC HMI Panel PC Ex 19" ■ More information Additional information is available on the Internet at: http://www.siemens.com/simatic-hmi-ex Siemens ST 80 / ST PC · 2013 3/29 © Siemens AG 2013 HMI devices for special requirements HMI devices for hazardous areas SIMATIC HMI Thin Client Ex ■ Overview HMI Thin Client Ex IECEx • Network 10/100 Base-Tx • Network 10/100 Base-Fx GOST-R • Network 10/100 Base-Tx • Network 10/100 Base-Fx 3 6AV7200-0... General features Design Thin Client built-in unit, available in protective enclosure as an option Front 15", 19", and 15" sunlight readable display Operation Touch with 8 function keys MTBF backlight 50 000 h Operating system Closed system on Windows XP Embedded basis Mass storage Integrated Power supply 24 V DC, max. 2.1 A (19") KGS Ex d e ia ib mb [ia ib] IIC T4 Ex ia tb [ia ib] IIIC T80°C Db IP66 • Network 10/100 Base-Fx • Network 10/100 Base-Fx IECEx • Network 10/100 Base-Tx • Network 10/100 Base-Fx Ethernet 100 Mbit Ex e, or alternatively fiber-optics 100 Mbit (SC) Ex op is USB 2.0 2 x Ex i, 2 x Ex e (Zone 1) or 2 x Ex nA (Zone 2) GOST-R • Network 10/100 Base-Tx Serial 1 x RS232 or 1 x RS422/485 • Network 10/100 Base-Fx Degree of protection IP66 at front, IP65 at rear, IP66 in protective enclosure CSA Ambient temperature during operation - 20 °C ... + 50 °C, cold start -10 °C, with optional additional heating down to -30 °C Relative humidity during operation 90 % at 40 °C, no condensation Ambient conditions InMetro • Network 10/100 Base-Tx Devices in "Zone 1" version ATEX directive 94/9/EC • Network 10/100 Base-Tx • Network 10/100 Base-Fx II 2 (2) G Ex d e ia ib mb [ia ib] IIC T4 Gb II 2 (2) D Ex ia tb [ia ib] IIIC T80°C Db IP66 II 2 (2) G Ex d e ia ib mb [ia ib op is] IIC T4 Gb II 2 (2) D Ex ia tb [ia ib op is] IIIC T80°C Db IP66 Ex d e ia ib mb [ia ib] IIC T4 Gb Ex ia tb [ia ib] IIIC T80°C Db IP66 Ex d e ia ib mb [ia ib op is] IIC T4 Gb Ex ia tb [ia ib op is] IIIC T80°C Db IP66 Devices in version "Zone 2" ATEX directive 94/9/EC • Network 10/100 Base-Tx Interfaces Approvals/directives 2 Ex d e ia ib mb [iaib] IIC T4 DIP A21 TA80°C, IP66 2 Ex d e ia ib mb [iaibopis] IIC T4 DIP A21 TA80°C, IP66 Ex d e ia ib mb [ia ib] IIC T4 Gb, Type 4X, IP66 Class II, Division 1, Groups E, F, G, T80°C Ex ia tb [ia ib] IIIC T80°C Db, IP66 ■ Technical specifications HMI Thin Client Ex Ex d e ia ib mb [ia ib] IIC T4 Gb Ex ia tb [ia ib] IIIC T80°C Db IP66 Ex d e ia ib mb [ia ib op is] IIC T4 Gb Ex ia tb [ia ib op is] IIIC T80°C Db IP66 CSA InMetro • Network 10/100 Base-Tx SIMATIC HMI Thin Client Ex with international approvals for operation and monitoring in hazardous areas. 6AV7200-0... • Network 10/100 Base-Fx II 3 (2/3) G Ex d e ia ib mb nA [ib Gb] [ic] IIC T4 Gc II3 (2/3) D Ex ia tc [ib Db] [ic] IIIC T80°C Dc IP66 II 3 (2/3) G Ex d e ia ib mb nA [ib op is Gb] [ic] IIC T4 Gc II 3 (2/3) D Ex ia tc [ib op is Db] [ic] IIIC T80°C Dc IP66 Ex d e ia ib mb nA [ib Gb] [ic] IIC T4 Gc Ex ia tc [ib Db] [ic] IIIC T80°C Dc IP66 Ex d e ia ib mb nA [ib op is Gb] [ic] IIC T4 Gc Ex ia tc [ib op is Db] [ic] IIIC T80°C Dc IP66 2 Ex de i a ib mb nA [ib][ic] IIC T4 DIP A21 TA80°C, IP66 2 Ex de i a ib mb nA [ibopis][ic] IIC T4 DIP A21 TA80°C, IP66 Ex d e ia ib mb nA [ib Gb] [ic] IIC T4 Gc, Type 4X, IP66 Class II, Division 2, Groups E, F, G, T80°C; Ex ia tc [ib ic] IIIC T80°C Dc, IP66 Ex d e ia ib mb nA [ib Gb] [ic] IIC T4 Gc Ex ia tc [ib Db] [ic] IIIC T80°C Dc IP66 Ex d e ia ib mb nA [ib op is Gb] IIC T4 Ex ia tc [ib op is Db] [ic] IIIC T80°C Dc IP66 Protocols RDP, RealVNC Digital KVM switch Input: DVI / VGA, PS/2 / USB, output: RJ45 (IP network) Dimensions 3/30 Siemens ST 80 / ST PC · 2013 Mounting dimensions (W x H x D) in mm 15": 427.5 x 327.5 x 165 19": 522.5 x 412.5 x 165 Front dimensions in mm 15": 440 x 340 19": 535 x 425 Weight 15": 15 kg, 19": 23 kg © Siemens AG 2013 HMI devices for special requirements HMI devices for hazardous areas SIMATIC HMI Thin Client Ex ■ Ordering data SIMATIC HMI Thin Client Ex Design / display size • Zone 2: 15" Touch with function keys • Zone 2: 19" Touch with function keys • Zone 1: 15" Touch with function keys • Zone 1: 19" Touch with function keys • Zone 2: 15" Touch, sunlight readable with function keys • Zone 1: 15" Touch, sunlight • readable with function keys Communication interfaces • 10/100 base Tx, Ex e • 100 base Fx FOC (SC), Ex op is Enclosure options (device is delivered already fitted) • without • Stainless steel enclosure for: - Wall mounting - Stand (incl. coupling, 300° rotation possible) - Suspension bracket (incl. coupling, 300° rotation possible) - Support arm (incl. coupling, 300° rotation possible) - Swivel arm from above (incl. coupling, 300° rotation possible) Order No. 6AV7200- Order No. 077 0 0-77A0 A B D E Digital KVM for HMI Thin Client Ex 6AV7675-0EX00-0AA0 USB drive • Intrinsically-safe, 8 GB • Intrinsically-safe, 8 GB with recovery function 6AV7675-0FX00-0AA0 6AV7675-0FX10-0AA0 Ethernet switch 6AV7675-0PX00-0AA0 With FOC 4 x 100 Base Tx, 1 x 100 Base (MTRJ) Fx Ex op is G H A B 3 0 2 3 4 5 6 External keyboard for enclosure (incl. keyboard enclosure) • without • QWERTZ keyboard • QWERTY keyboard • AZERTY keyboard • QWERTZ keyboard with trackball • QWERTY keyboard with trackball • AZERTY keyboard with trackball Further options together with stainless steel enclosure • Breather glands • Heating (requires breather glands) • Handles • Front USB (at bottom) Accessories A B C D E F G -z -z -z -z A B C D 0 0 0 0 1 1 1 1 Siemens ST 80 / ST PC · 2013 3/31 © Siemens AG 2013 HMI devices for special requirements HMI devices for hazardous areas SIMATIC HMI Thin Client Ex ■ Dimensional drawings Legend: i = Clamping frame h = Mounting clamp (10 x) j = Control cabinet or enclosure All dimensions in mm. For mounting cut-out see technical specifications. G_ST80_XX_00419 327.5+0.5 340 3 165 326 440 h 426 i 427.5+0.5 j SIMATIC HMI Thin Client Ex 15" 15" touch front Width in mm Height in mm Depth in mm Operating unit 440 340 165 Installation cutout 427.5 ± 0.5 327.5 ± 0.5 - G_ST80_XX_00420 412.5+0.5 165 411 425 535 h 521 i 522.5+0.5 j SIMATIC HMI Thin Client Ex 19" 19" touch front Width in mm Height in mm Depth in mm Operating unit 535 425 165 Installation cutout 522 ± 0.5 412.5 ± 0.5 - ■ More information Additional information is available on the Internet at: http://www.siemens.com/simatic-hmi-ex 3/32 Siemens ST 80 / ST PC · 2013 4 © Siemens AG 2013 HMI Software 4/2 Introduction 4/5 4/6 4/12 4/14 4/19 4/25 4/31 4/32 4/34 4/36 4/37 4/38 4/42 4/44 4/47 4/50 HMI Software in the TIA Portal SIMATIC WinCC (TIA Portal) Engineering SIMATIC WinCC (TIA Portal) Runtime WinCC Runtime Advanced WinCC Runtime Professional WinCC Runtime Communication SIMATIC WinCC (TIA Portal) options WinCC Recipes WinCC Logging WinCC Audit SIMATIC Logon WinCC Sm@rtServer WinCC Server / WinCC Client WinCC WebNavigator WinCC DataMonitor WinCC ControlDevelopment 4/51 4/52 4/56 Software for energy management SIMATIC B.Data SIMATIC powerrate 4/59 SIMATIC WinCC flexible HMI system SIMATIC WinCC flexible ES SIMATIC WinCC flexible RT SIMATIC WinCC flexible options WinCC flexible /ChangeControl WinCC flexible /Archives WinCC flexible /Recipes WinCC flexible /Audit SIMATIC Logon for WinCC flexible WinCC flexible /Sm@rtAccess WinCC flexible /Sm@rtService WinCC flexible /OPC server WinCC flexible /ProAgent 4/60 4/64 4/71 4/72 4/73 4/74 4/75 4/76 4/78 4/82 4/85 4/87 4/88 4/89 4/107 4/108 4/110 4/111 4/112 4/115 4/116 4/117 4/118 4/120 4/122 4/124 4/126 4/127 4/129 4/130 4/131 4/132 4/133 4/134 4/138 4/139 SCADA system SIMATIC WinCC SIMATIC WinCC SIMATIC WinCC options SIMATIC BATCH for WinCC SIMATIC Information Server SIMATIC Logon SIMATIC Maintenance Station SIMATIC Process Historian WinCC/Calendar Scheduler WinCC/Central Archive Server (CAS) WinCC/ChangeControl & WinCC/Audit WinCC/Connectivity Pack & WinCC Connectivity Station WinCC/DataMonitor WinCC/DowntimeMonitor WinCC/Event Notifier WinCC/IndustrialDataBridge WinCC/IndustrialX WinCC/Open Development Kit (ODK) WinCC/ProAgent WinCC/Redundancy WinCC/Server WinCC/TeleControl WinCC/User Archives WinCC/Web Navigator 4/144 WinCC add-ons and partner management 4/146 SCADA System SIMATIC WinCC Open Architecture SIMATIC WinCC Open Architecture Add-ons 4/155 4/161 SIMATIC ProAgent process diagnostics software Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 HMI Software Introduction HMI software ■ Overview Engineering Software WinCC Professional WinCC Advanced WinCC Comfort WinCC Basic Integrated runtime module Comfort Panels Mobile Panels x77 Panels and Multi Panels PC-based single-user system, e.g. SIMATIC IPC PC-based multi-user system Integrated runtime module WinCC Runtime Advanced WinCC Runtime Professional SCADA functionality G_ST80_XX_00461 Runtime Software and target systems Basic Panels 4 With the product families SIMATIC WinCC (TIA Portal), SIMATIC WinCC flexible, SIMATIC WinCC and SIMATIC WinCC Open Architecture, SIMATIC HMI offers visualization and configuration software for the entire HMI spectrum: • SIMATIC WinCC (TIA Portal) Creation of applications in the machine-level area and of process visualization or SCADA systems • SIMATIC WinCC flexible Creation of applications in the machine-level area: • SIMATIC WinCC Creation of process visualization or SCADA systems • SIMATIC WinCC Open Architecture Creation of applications with a high demand for customerspecific adaptations, large and/or complex applications, as well as projects that demand special system requirements and functions. SIMATIC WinCC (TIA Portal) WinCC (TIA Portal) is based on the new central engineering framework Totally Integrated Automation Portal (TIA Portal), which provides users with an integrated, efficient and intuitive solution to all automation tasks. SIMATIC WinCC (TIA Portal) covers applications in the machine-level area and applications in the process visualization or SCADA environment. WinCC (TIA Portal) offers the uniform and scalable configuration tools WinCC Basic, Comfort, Advanced and Professional for configuring the current SIMATIC HMI devices: • SIMATIC Basic Panels • SIMATIC Comfort Panels • SIMATIC Mobile Panels • SIMATIC Panels 77/177/277 series • SIMATIC Multi Panels of the 177/277/377 series • PC-based systems - SIMATIC WinCC Runtime Advanced - SIMATIC WinCC Runtime Professional In addition, WinCC (TIA Portal) offers: • Intuitive user interface with maximum degree of operator friendliness • Clear configuration of devices and network topologies • Shared data management and uniform symbols via controller and HMI • Optimum interaction with the controller and HMI in a working environment • Powerful editors for efficient engineering • Integrated mass data operations for efficient configuration • System diagnostics as an integral component • Comprehensive library concept 4/2 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 HMI Software Introduction HMI software ■ Overview (continued) SIMATIC WinCC flexible SIMATIC WinCC Covers applications in the machine-level area. WinCC flexible offers the integrated and scalable configuration tools WinCC flexible Micro, Compact, Standard and Advanced for configuring SIMATIC HMI devices: • SIMATIC Basic Panels • SIMATIC Mobile Panels • SIMATIC Micro Panels • SIMATIC Panels of the 70/170/270 series as well as C7-635 and C7-636 • SIMATIC Multi Panels of the 170/270/370 series • PC-based systems - SIMATIC WinCC flexible Runtime • Runs under Windows XP Professional / Windows 7 Professional, Ultimate, Enterprise • Expanded integration into STEP 7 and SIMOTION • Optionally expandable with functions for version administration and logging changes (WinCC flexible /ChangeControl) • Modular PC-based HMI solution for single-user systems directly at the machine level • Basic package for visualization, reporting and logging; can be expanded by implementing option packages • Flexible expansion possible with VB scripts and customized ActiveX controls created with OPP (Open Platform Program) The process visualization or SCADA system for visualizing and operating processes, production flows, machines and plants in all sectors – from the simple single-user station through to distributed multi-user systems with redundant servers and cross-location solutions with web clients. WinCC is the information hub for company-wide, vertical integration (process visualization and platform for IT & business integration). • For universal use thanks to solutions for all sectors, e.g. conforming to FDA 21 CFR Part 11, and multiple languages for worldwide use • All HMI functions on-board with industry-standard functions for signaling and acknowledging events, archiving of messages and measured values, logging of all process and configuration data, user administration and visualization (WinCC basic software). • Company-wide, flexible client/server structures with operator stations on the Web, distributed servers and data integrity thanks to redundancy • Easy to integrate over standard interfaces such as OPC (OLE for Process Control), WinCC OLE-DB, VBA (Visual Basic for Applications), VB script, C-API (ODK) • Integration platform in the company thanks to the Historian functionality integrated into WinCC based on the Microsoft SQL Server, standard and programming interfaces and tools and clients for evaluation • Modular expansion with options and add-ons as well as individual functional expansions with VB Script, Visual Basic for Applications, C-API (ODK) and integration of ActiveX elements. • Object-orientation supports efficient engineering and flexible plant expansion • For large, distributed systems with up to 2048 servers • Scalable – from a small single-user system up to a networked, redundant high-end system • WinCC OA can be used on any platform and is available for Windows, Linux and Solaris • Hot-standby redundancy and disaster recovery system assure maximum fail-safety and availability • WinCC OA offers a platform for customer-specific solutions • Extensive driver and interfacing options: S7, SINAUT, OPC, OPC UA, Modbus, IEC 60870-5-101/104, DNP3, BACnet, and many others. • Flexible logging of data either in file-based value archive or in a relational database (ORACLE) • Modular expansion is possible using options and add-ons as well as individual functional expansions by means of own script language CONTROL, API(C++) and integration of ActiveX elements Siemens ST 80 / ST PC · 2013 4/3 4 © Siemens AG 2013 HMI Software Introduction HMI software ■ Overview (continued) SIMATIC WinCC Open Architecture The SCADA system SIMATIC WinCC Open Architecture addresses applications with high demand for customer-specific adaptations, large and/or complex applications, as well as projects that demand special system requirements and functions. SIMATIC WinCC Open Architecture demonstrates its high performance in networked and redundant high-end control systems in particular. From the field level to the control station, from the machine to the company headquarters – integrated, high-performance communication is ensured. In every situation, a high level of availability, reliable information, fast interaction and user friendliness are guaranteed. Applications can also be changed without interrupting the process. Profitability, efficiency and safety are therefore always in equilibrium. With its disaster recovery system and SIL3 certification, SIMATIC WinCC Open Architecture demonstrates its reliability in a wide range of critical applications. 4 4/4 Siemens ST 80 / ST PC · 2013 SIMATIC WinCC Open Architecture is open for independent inhouse developments, which means that ideas can be turned into new applications quickly and easily. • Object-orientation supports efficient engineering and flexible plant expansion • For large, distributed systems with up to 2048 servers • Scalable – from a small single-user system up to a networked, redundant high-end system • WinCC OA can be used on any platform and is available for Windows, Linux and Solaris • Hot-standby redundancy and disaster recovery system assure maximum fail-safety and availability • WinCC OA offers a platform for customer-specific solutions • Extensive driver and interfacing options: S7, SINAUT, OPC, OPC UA, Modbus, IEC 60870-5-101/104, DNP3, BACnet, and many others. • Flexible logging of data either in file-based value archive or in a relational database (ORACLE) • Modular expansion is possible using options and add-ons as well as individual functional expansions by means of own script language CONTROL, API(C++) and integration of ActiveX elements © Siemens AG 2013 HMI Software HMI Software in the TIA Portal HMI Software in the TIA Portal ■ Overview SIMATIC WinCC (TIA Portal) engineering software • Family of configuration systems with WinCC Basic, Comfort, Advanced and Professional for SIMATIC operator panels, as well as for the PC-based visualization systems WinCC Runtime Advanced and WinCC Runtime Professional SIMATIC WinCC Runtime Advanced visualization software • PC-based HMI solution for single-user systems directly at the machine • Basic package for visualization, reporting and logging, user administration, can be expanded flexibly with VB scripts • Basic package expandable by means of option packages • Integration of customer-specific ActiveX Controls created with WinCC ControlDevelopment • Can be integrated into automation solutions based on TCP/IP networks • Expanded service concepts with remote operation, diagnostics and administration over the Intranet and Internet in combination with e-mail communication SIMATIC WinCC Runtime Professional visualization software • PC-based operator control and monitoring system for visualization and operator control of processes, production flows, machines and plants in all sectors – from the simple singleuser station through to distributed multi-user systems and cross-location solutions with web clients. WinCC Runtime Professional is the information hub for corporation-wide vertical integration. • Industry-standard functions for signaling and acknowledging events, archiving of messages and measured values, logging of all process and configuration data, user administration, can be expanded flexibly with VB and C scripts • Basic package expandable by means of option packages • Also included are APIs for the Runtime to utilize the open programming interfaces • Integration of customer-specific ActiveX Controls created with WinCC ControlDevelopment 4 Siemens ST 80 / ST PC · 2013 4/5 © Siemens AG 2013 HMI Software HMI Software in the TIA Portal SIMATIC WinCC (TIA Portal) Engineering ■ Overview ■ Application • Integrated family of engineering tools for configuring SIMATIC HMI operator panels, as well as for the PC-based visualization systems WinCC Runtime Advanced and WinCC Runtime Professional. • WinCC (TIA Portal) is based on the new central engineering framework Totally Integrated Automation Portal (TIA Portal), which offers the user a uniform, efficient and intuitive solution to all automation tasks. • WinCC (TIA Portal) also offers uniform engineering from the Basic Panel through to the SCADA application. • Together with the STEP 7 (TIA Portal) products, WinCC (TIA Portal) forms the optimum solution for integrated, efficient engineering. Current version: • SIMATIC WinCC Basic V12 SP1 • SIMATIC WinCC Comfort V12 SP1 • SIMATIC WinCC Advanced V12 SP1 • SIMATIC WinCC Professional V12 SP1 ■ Benefits 4 • The integrated configuration software reduces training, maintenance and service overhead and protects the customer's investments. • Minimized engineering overhead and reduction of lifecycle costs thanks to Totally Integrated Automation (TIA) • Minimized configuration overhead due to reuse of scalable and dynamizable objects • Intelligent tools for efficient and simple configuration: - Wizard for defining the basic structure of the HMI project - Table-based editors simplify the generation and processing of similar types of object, e.g. for tags, texts, or alarms. - Complex configuration tasks such as the definition of paths of motion or the creation of the fundamental operator prompting are simplified by means of graphical configuration. • Comprehensive support of multi-language configurations for worldwide use - Selectable views for entering configuration data in several languages - System and user-specific text lexicons - Export/import of language-dependent texts • Investment protection due to - Import of the configuration from WinCC flexible 2008 SP2 and 2008 SP3 - Transfer of the configuration from WinCC V7.0 SP3 4/6 Siemens ST 80 / ST PC · 2013 SIMATIC WinCC in the editions Basic, Comfort, Advanced and Professional are innovative engineering tools for configuring SIMATIC HMI operator panels, as well as for the PC-based visualization systems WinCC Runtime Advanced and WinCC Runtime Professional. Depending on the selected product, various target systems can be configured: WinCC Basic • Basic Panels WinCC Comfort • As WinCC Basic, plus: • Comfort Panels • Mobile Panels: Mobile Panel 177, Mobile Panel 277 • Panels of the 70 series: OP 73, OP 77A, OP 77B • Panels of the 170 series: TP 177A, TP 177B, OP 177B • Panels of the 270 series: TP 277, OP 277 • Multi Panels: MP 177, MP 277, MP 377 WinCC Advanced • As WinCC Comfort, plus: • SIMATIC PCs with WinCC Runtime Advanced: - SIMATIC Panel PC: IPC277D, Panel PC 477B, IPC477C, IPC477D, Panel PC 577B, IPC577C, Panel PC 677B, IPC677C - SIMATIC Box PC: IPC227D, Box PC 427B, IPC427C, IPC427D, Box PC 627B, IPC627C, Box PC 827B, IPC827C - SIMATIC Rack PC: Rack PC 547B, IPC547C, IPC547D, Rack PC 647B, IPC647C, Rack PC 847B, IPC847C - SIMATIC modular Embedded Controller: EC31 • Standard PC with WinCC Runtime Advanced • SINUMERIK PC: PCU 50.3, PCU 50.5 WinCC Professional • As WinCC Advanced, plus: • SIMATIC PCs with WinCC Runtime Professional: - SIMATIC Panel PC: IPC477C, IPC477D, Panel PC 577B, IPC577C, Panel PC 677B, IPC677C, - SIMATIC Box PC: IPC427C, IPC427D, Box PC 627B, IPC627C, IPC827C - SIMATIC Rack PC: Rack PC 547B, IPC547C, IPC547D, Rack PC 647B, IPC647C, Rack PC 847B, IPC847C • Standard PC with WinCC Runtime Professional © Siemens AG 2013 HMI Software HMI Software in the TIA Portal SIMATIC WinCC (TIA Portal) Engineering ■ Design The functionalities of the engineering tools of the SIMATIC WinCC family are based on each other. The available editors are largely determined by the respective configurable target systems and their function. A more comprehensive engineering tool such as WinCC Advanced can always be used to configure lower-level target devices as well (e.g. Basic Panels) A Powerpack can be used to upgrade from a smaller edition to a larger one. This does not apply to WinCC Basic. The functionality of WinCC engineering tools already contains the configuration support of the available Runtime options for SIMATIC Panels, WinCC Runtime Advanced or WinCC Runtime Professional, irrespective of the purchased RT licenses. A separate license is required for the target system when using the configured Runtime options. ■ Function Integration into automation systems Integration into the SIMATIC Totally Integrated Automation Portal (TIA Portal) • Shared data management and uniform symbols via the controller and HMI • Optimum interaction between the controller and HMI in a working environment • System diagnostics as an integral component • Shared use of communication settings and process point definitions • Simple dragging and dropping of tags from STEP 7 to an HMI device, e.g. onto a screen • Excellent support for the new SIMATIC S7-1500 controller - With symbolic addressing - Access to the new memory-optimized data blocks - New alarm and diagnostics concept Configuration interface • Intuitive user interfaces with maximum degree of user friendliness • Comprehensive and fast access to editors and project data • Adaptive user interface of engineering tools depending on configured target system • User-definable user interface settings, e.g. layout, toolbars • Integrated mass data operations for efficient configuration Project handling • Device-independent configuration data can be used on a variety of target systems without the need for conversion. The interface adapts itself to the functional possibilities of the target device. • Cross-device utilization of common configuration data (e.g. alarm classes, text library) in multi-device projects • Wizard-assisted definition of basic structure of HMI projects (e.g. display layout, operator prompting) Screen editor with comprehensive options for efficient and fast screen configuration • Generation of interconnected screen objects via Drag&Drop, e.g. tags for the creation of input/output fields with process interfacing or buttons with screen selection function • Definition of screen templates and functions (comparable with the Slide Master in MS PowerPoint) • User-friendly editor for the creation of faceplates with defined external interface from screen objects • Graphics-based configuration of motion paths • Layer technology with up to 32 layers • Tools for the Align, Rotate and Mirror functions Import/export • of tags, links, text lists, and alarms Tabular editors • Quick and easy generation and modification of configuration objects of the same type, e.g. tags, texts or messages, in tabular editors • Intelligent default settings depending on previously configured data, e.g. automatic incrementing of addresses when generating consecutive tags • Simple access to the properties of an object without superfluous user intervention • Simultaneous modification of common object properties Object-based data management with user-friendly search and edit options • Configuration of alarms and logs directly on the HMI tag, no switching between different editors • Cross-reference list with direct access to all objects, e.g. for editing or selection • Search for objects in entire project • Text search and replace functions Project documentation • Selective project documentation, the following contents can be printed: - An entire project - One or more project-associated devices - Contents of an editor - Libraries Siemens ST 80 / ST PC · 2013 4/7 4 © Siemens AG 2013 HMI Software HMI Software in the TIA Portal SIMATIC WinCC (TIA Portal) Engineering ■ Function (continued) Libraries for predefined/user-defined configuration objects • Storage of all configuration objects in the library, e.g. blocks and even entire screens or tags • Faceplates can be constructed from simple screen objects on a customer-specific or project-specific basis. Changes to these faceplates can be made centrally (block definition). • A large number of scalable and dynamizable screen objects is included in the scope of delivery • Size-scalable graphics for industrial applications are included in the scope of delivery • Preview function for library objects System prerequisites WinCC engineering software Processor type (min.) Core i5; 2.4 GHz or comparable RAM (min.) 3 GB (32-bit operating system) 8 GB (64-bit operating system) Free hard disk space 2 GB on system drive "C:" Operating systems 32-bit operating systems • Windows XP Home SP3 (only WinCC Basic) • Windows XP Professional SP3 • Windows 7 Home Premium SP1 (only WinCC Basic) • Windows 7 Professional SP1 • Windows 7 Enterprise SP1 • Windows 7 Ultimate SP1 • Windows Server 2003 R2 Standard Edition SP2 (only WinCC Advanced and Professional) • Windows Server 2008 Standard Edition SP2 (only WinCC Advanced and Professional) Language support • Multilingual project creation (max. 32 languages) in editors thanks to selectable views • Central management of language-specific texts and graphics in libraries • Edit, export and import of texts for translation • Language-specific graphics 4 Visual Basic and C-Script Support • IntelliSense function for fast programming of access to runtime objects • Simple creation of control sequences in script code • Visual Basic Script debugging in simulator and WinCC Runtime Advanced and WinCC Runtime Professional Test and commissioning support • Simulation of HMI projects on engineering PC • Marking of incomplete or incorrect configuration directly in the respective editor • Jump to error cause based on alarm messages in the Compiler Migration of existing HMI projects • Data transfer in projects from WinCC flexible • Data transfer in projects from WinCC 64-bit operating systems • Windows 7 Home Premium SP1 (only WinCC Basic) • Windows 7 Professional SP1 • Windows 7 Enterprise SP1 • Windows 7 Ultimate SP1 • Windows Server 2008 R2 Standard Edition SP2 (only WinCC Advanced and Professional) Screen resolution at least 1280 x 1024 Optical drive DVD-ROM Note: Opening several instances of WinCC on your engineering PC at the same time may result in more demanding hardware requirements. In addition to WinCC, Windows also requires space on the hard disk; e.g. free disk space should be available for the swap file. The following formula has proven itself in the past: Size of swap file = 3 x size of RAM. For further information, refer to your Windows documentation 4/8 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 HMI Software HMI Software in the TIA Portal SIMATIC WinCC (TIA Portal) Engineering ■ Ordering data Order No. WinCC Basic V12 SP1 Engineering software for the configuration and simulation of Basic Panels; electronic documentation in English, French, German, Italian, Spanish, simplified Chinese, traditional Chinese • Software and documentation on DVD, floating license, license key on USB stick • New type of delivery: Online software delivery 1), floating license, software and license key download, e-mail address required for the delivery 6AV2100-0AA02-0AA5 6AV2100-0AA02-0AH5 WinCC Comfort V12 SP1 Engineering software for the configuration and simulation of SIMATIC Panels; electronic documentation in English, French, German, Italian, Spanish, simplified Chinese, traditional Chinese • Software and documentation on DVD, floating license, license key on USB stick • New type of delivery: Online software delivery 1), floating license, software and license key download, e-mail address required for the delivery Engineering software for the configuration and simulation of SIMATIC Panels; WinCC Runtime Professional (with max. 4096 PowerTags), WinCC Runtime Advanced electronic documentation in English, French, German, Italian, Spanish, simplified Chinese, traditional Chinese • Software and documentation on DVD, floating license, license key on USB stick • New type of delivery: Online software delivery 1), floating license, software and license key download, e-mail address required for the delivery 6AV2103-0HA02-0AA5 6AV2103-0HA02-0AH5 WinCC Professional max. PowerTags V12 SP1 6AV2101-0AA02-0AA5 6AV2101-0AA02-0AH5 WinCC Advanced V12 SP1 Engineering software for the configuration and simulation of SIMATIC Panels; WinCC Runtime Advanced, electronic documentation in English, French, German, Italian, Spanish, simplified Chinese, traditional Chinese • Software and documentation on DVD, floating license, license key on USB stick • New type of delivery: Online software delivery 1), floating license, software and license key download, e-mail address required for the delivery Order No. WinCC Professional 4096 PowerTags V12 SP1 Engineering software for the configuration and simulation of SIMATIC Panels; WinCC Runtime Professional (unlimited PowerTags), WinCC Runtime Advanced electronic documentation in English, French, German, Italian, Spanish, simplified Chinese, traditional Chinese • Software and documentation on DVD, floating license, license key on USB stick • New type of delivery: Online software delivery (OSD) 1), floating license, software and license key download, e-mail address required for the delivery 4 6AV2103-0XA02-0AA5 6AV2103-0XA02-0AH5 Trial licenses 6AV2102-0AA02-0AA5 6AV2102-0AA02-0AH5 on DVD, 21 day trial • WinCC Basic V12 SP1 • WinCC Comfort/Advanced V12 SP1 • WinCC Professional V12 SP1 6AV2100-0AA02-0AA7 6AV2102-0AA02-0AA7 6AV2103-0AA02-0AA7 WinCC Professional 512 PowerTags V12 SP1 Engineering software for the configuration and simulation of SIMATIC Panels; WinCC Runtime Professiona l (with max. 512 PowerTags), WinCC Runtime Advanced electronic documentation in English, French, German, Italian, Spanish, simplified Chinese, traditional Chinese • Software and documentation on DVD, floating license, license key on USB stick • New type of delivery: Online software delivery 1), floating license, license key download, e-mail address required for the delivery 1) 6AV2103-0DA02-0AA5 6AV2103-0DA02-0AH5 Current information and availability regarding the new delivery package can be found at: http://www.siemens.com/tia-online-software-delivery Siemens ST 80 / ST PC · 2013 4/9 © Siemens AG 2013 HMI Software HMI Software in the TIA Portal SIMATIC WinCC (TIA Portal) Engineering ■ Ordering data Order No. Software Update Service SIMATIC WinCC Engineering System Powerpacks (without version change) For a period of 12 months and for a fixed price, the customer is automatically provided with all upgrades and service packs for each installed WinCC engineering system or option. Floating license, license key only on USB stick • WinCC Basic to WinCC Comfort V12 2) • WinCC Comfort to WinCC Advanced V12 • WinCC Advanced to WinCC Professional 512 PowerTags V12 • WinCC Professional Powerpack 512 PowerTags to 4096 PowerTags V12 • WinCC Professional Powerpack 4096 PowerTags to max. PowerTags V12 6AV2101-2AA02-0AC5 6AV2102-2AA02-0BD5 6AV2103-2AD02-0AC5 6AV2103-2DH02-0BD5 6AV2103-2HX02-0BD5 Online software delivery (OSD) 1) 4 Order No. Powerpacks Floating license, license key download only e-mail address required for the delivery • WinCC Basic to WinCC Comfort V12 2) • WinCC Comfort to WinCC Advanced V12 • WinCC Advanced to WinCC Professional 512 PowerTags V12 • WinCC Professional Powerpack 512 PowerTags to 4096 PowerTags V12 • WinCC Professional Powerpack 4096 PowerTags to max. PowerTags 6AV2101-2AA02-0BJ5 6AV2102-2AA02-0BJ5 6AV2103-2AD02-0BJ5 6AV2103-2DH02-0BJ5 6AV2103-2HX02-0BJ5 The contract is automatically extended by a further year unless canceled at least 12 weeks prior to expiration. Software Update Service (Standard Edition) The delivery is implemented according to the number of ordered SUS products (e.g. 10 upgrade packages with 10 DVDs, 10 USB flash drives, etc.) • WinCC Comfort • WinCC Advanced • WinCC Professional 512 PowerTags • WinCC Professional 4096 PowerTags • WinCC Professional max. PowerTags 6AV6612-0AA00-0AL0 6AV6613-0AA00-0AL0 6AV2103-0DA00-0AL0 6AV2103-0HA00-0AL0 6AV2103-0XA00-0AL0 Software Update Service (Compact Edition) The delivery items are combined. For several contracts, only 1 package with 1 data medium set, 1 USB flash drive with the corresponding number of licenses and the corresponding number of CoLs will be supplied. Delivery items to be combined must be ordered as one item. • WinCC Comfort • WinCC Advanced • WinCC Professional 512 PowerTags • WinCC Professional 4096 PowerTags • WinCC Professional max. PowerTags 6AV6612-0AA00-0AM0 6AV6613-0AA00-0AM0 6AV2103-0DA00-0AM0 6AV2103-0HA00-0AM0 6AV2103-0XA00-0AM0 Online software delivery (OSD) 1) Software Update Service (Download) All deliveries to be downloaded. E-mail address required for the delivery • WinCC Comfort • WinCC Advanced • WinCC Professional 512 PowerTags • WinCC Professional 4096 PowerTags • WinCC Professional max. PowerTags 4/10 Siemens ST 80 / ST PC · 2013 6AV6612-0AA00-0AY0 6AV6613-0AA00-0AY0 6AV2103-0DA00-0AY0 6AV2103-0HA00-0AY0 6AV2103-0XA00-0AY0 1) Current information and availability regarding the new delivery package can be found at: http://www.siemens.com/tia-online-software-delivery 2) Valid only for order numbers 6AV2100-0AA02-0AA5 and 6AV2100-0AA02-0AH5 © Siemens AG 2013 HMI Software HMI Software in the TIA Portal SIMATIC WinCC (TIA Portal) Engineering ■ Ordering data Order No. Order No. Upgrades Upgrades WinCC V11 -> WinCC V12 SP1 Software and documentation on DVD, upgrade license, license key on USB stick • SIMATIC WinCC Basic V12 SP1 Upgrade V11 -> V12 SP1 • SIMATIC WinCC Comfort V12 SP1 Upgrade V11 -> V12 SP1 • SIMATIC WinCC Advanced V12 SP1 Upgrade V11 -> V12 SP1 • SIMATIC WinCC Professional 512 PowerTags V12 SP1 Upgrade V11 -> V12 SP1 • SIMATIC WinCC Professional 4096 PowerTags V12 SP1 Upgrade V11 -> V12 SP1 • SIMATIC WinCC Professional max. PowerTags V12 SP1 Upgrade V11 -> V12 SP1 WinCC flexible 2008 -> WinCC V12 SP1 Software and documentation on DVD, upgrade license, license key on USB stick • WinCC flexible 2008 Compact to WinCC Comfort V12 SP1 • WinCC flexible 2008 Standard to WinCC Comfort V12 SP1 • WinCC flexible 2008 Advanced to WinCC Advanced V12 SP1 6AV2101-4AB02-0AE5 Online software delivery (OSD) 1) Upgrade license, software and license key download, e-mail address required for the delivery • WinCC flexible 2008 Compact to WinCC Comfort V12 SP1 • WinCC flexible 2008 Standard to WinCC Comfort V12 SP1 • WinCC flexible 2008 Advanced to WinCC Advanced V12 SP1 6AV2101-4AB02-0AK5 Online software delivery (OSD) 1) Floating license, software and license key download e-mail address required for the delivery • SIMATIC WinCC Basic V12 SP1 Upgrade V11 -> V12 SP1 • SIMATIC WinCC Comfort V12 SP1 Upgrade V11 -> V12 SP1 • SIMATIC WinCC Advanced V12 SP1 Upgrade V11 -> V12 SP1 1) 6AV2100-3AA02-0AE5 6AV2101-3AA02-0AE5 6AV2102-3AA02-0AE5 6AV2103-3DA02-0AE5 6AV2103-3HA02-0AE5 6AV2103-3XA02-0AE5 6AV2100-3AA02-0AK5 6AV2101-3AA02-0AK5 6AV2102-3AA02-0AK5 WinCC V7 RC -> WinCC V12 SP1 Software and documentation on DVD, upgrade license, license key on USB stick • Upgrade SIMATIC WinCC V7.0 RC 128 -> WinCC Professional 512 PowerTags V12 SP1 and WinCC RT Professional 128 PowerTags • Upgrade SIMATIC WinCC V7.0 RC 512 -> WinCC Professional 512 PowerTags V12 SP1 and WinCC RT Professional 512 PowerTags • Upgrade SIMATIC WinCC V7.0 RC 2048 -> WinCC Professional 4096 PowerTags V12 SP1 and WinCC RT Professional 2048 PowerTags • Upgrade SIMATIC WinCC V7.0 RC 8192 -> WinCC Professional max. PowerTags V12 SP1 and WinCC RT Professional 8192 PowerTags • Upgrade SIMATIC WinCC V7.0 RC 65536 -> WinCC Professional max. PowerTags V12 SP1 and WinCC RT Professional 65536 PowerTags 6AV2101-4BB02-0AE5 6AV2102-4AA02-0AE5 6AV2101-4BB02-0AK5 6AV2102-4AA02-0AK5 4 6AV2103-4BD02-0AE5 6AV2103-4DD02-0AE5 6AV2103-4FH02-0AE5 6AV2103-4KX02-0AE5 6AV2103-4MX02-0AE5 Current information and availability regarding the new delivery package can be found at: http://www.siemens.com/tia-online-software-delivery ■ More information Further information can be found in the Internet at: http://www.siemens.com/tia-portal Siemens ST 80 / ST PC · 2013 4/11 © Siemens AG 2013 HMI Software SIMATIC WinCC (TIA Portal) Runtime SIMATIC WinCC (TIA Portal) Runtime ■ Overview SIMATIC WinCC Runtime Professional visualization software • PC-based operator control and monitoring system for visualization and operator control of processes, production flows, machines and plants in all sectors – from the simple singleuser station through to distributed multi-user systems and cross-location solutions with web clients. WinCC Runtime Professional is the information hub for corporation-wide vertical integration. • Industry-standard functions for signaling and acknowledging events, archiving of messages and measured values, logging of all process and configuration data, user administration, can be expanded flexibly with VB and C scripts • Basic package expandable by means of option packages • Also included are APIs for the Runtime to utilize the open programming interfaces 4 SIMATIC WinCC Runtime Advanced visualization software • PC-based HMI solution for single-user systems directly at the machine • Basic package for visualization, reporting and logging, user administration, can be expanded flexibly with VB scripts • Basic package expandable by means of option packages • Can be integrated into automation solutions based on TCP/IP networks • Expanded service concepts with remote operation, diagnostics and administration over the intranet and Internet in combination with email communication 4/12 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 HMI Software SIMATIC WinCC (TIA Portal) Runtime WinCC Runtime Advanced ■ Overview PC-based HMI solution for single-user systems directly at the machine. SIMATIC WinCC Runtime Advanced is configured with the SIMATIC WinCC Advanced or SIMATIC WinCC Professional configuration software. ■ Benefits • Functions for all visualization tasks: - Operator functions - Graphics and trend displays - Alarm logging - Report system - Archiving (option) - Recipe management (option) - Audit Trail (option) • Flexible runtime functionality due to Visual Basic scripts • Innovative service concepts with remote operation, diagnostics and administration via intranet and Internet as well as e-mail communication to increase availability (option) • Support for simple distributed automation solutions based on TCP/IP networks at the machine level (option) • Part of the Totally Integrated Automation Portal - Direct access to the tag and message configuration of the SIMATIC controller - Excellent support of the new SIMATIC S7-1500 controller With symbolic addressing Access to the new memory-optimized data blocks New alarm and diagnostics concept - Integrated diagnostic functions for increasing productivity ■ Application SIMATIC WinCC Runtime Advanced is the high-performance visualization software for simple, machine-oriented visualization tasks. It can be used as a single-user solution for all automation applications in production automation, process automation and building services automation. SIMATIC WinCC Runtime Advanced can be used in combination with the following HMI devices: • SIMATIC Panel PC: IPC277D, Panel PC 477B, HMI IPC477C, IPC477D, Panel PC 577B, HMI IPC577C, Panel PC 677B, HMI IPC677C • SIMATIC Box PC: IPC227D, Box PC 427B, IPC427C, IPC427D, Box PC 627B, IPC627C, Box PC 827B, IPC827C • SIMATIC Rack PC: Rack PC 547B, IPC547C, IPC547D, Rack PC 647B, IPC647C, Rack PC 847B, IPC847C • SIMATIC modular Embedded Controller: EC31 • SINUMERIK PC: PCU 50.3, PCU 50.5 • Standard PCs with resolutions (W x H in pixels) of: - 4:3 format: 640 x 480, 800 x 600, 1024 x 768, 1280 x 1024, 1600 x 1200 - Widescreen format: 800 x 480, 1280 x 800, 1366 x 768, 1440 x 900, 1680 x 1050, 1920 x 1080, 1920 x 1200, 1980 x 1080 4 Siemens ST 80 / ST PC · 2013 4/13 © Siemens AG 2013 HMI Software SIMATIC WinCC (TIA Portal) Runtime WinCC Runtime Advanced ■ Design SIMATIC WinCC Runtime Advanced is available as a software package with 128, 512, 2 048 or 4 096 PowerTags. The term PowerTags is used to identify process variables and area pointers that have a process link to the controller. Variables without process link, constant limit values of variables, and messages (up to 4 000 bit-triggered messages) are also available for additional system performance. The range of functions of WinCC Runtime Advanced includes the centralized HMI components for visualizing and reporting, and it can be expanded to suit requirements and costs by using optional packages. SIMATIC WinCC Runtime Advanced is configured with the SIMATIC WinCC Advanced or SIMATIC WinCC Professional configuration software. ■ Function Visualization via Windows-compliant user interface 4 Made up of parameterizable screen objects and faceplates created on a project-specific basis: • Numeric and alphanumeric input/output fields • Static text and graphic display plus vector graphics • Dynamizable graphics from HMI symbol library • Bar graph, trend curve graph with scroll and zoom function as well as read line • Signal-specific text and graphic lists • Buttons and switches for operator-process communication • Editing fields for process values (signals) • Analog display, slider as example for further screen objects • Project-specific faceplates created from basic objects of the system • Graphic displays for various standard graphic formats, e.g. bitmaps, .jpg, .wmf 4/14 Siemens ST 80 / ST PC · 2013 Alarms and messages • Discrete alarms and analog alarms as well as event-driven Alarm-S/Alarm-D message procedure with SIMATIC S7 • The new alarm and diagnostics concept of the S7-1500 controller is also supported • Freely-definable alarm classes for definition of acknowledgment response and display of alarm events Logging of alarms and process values 1) • Logging in files (e.g. CSV or TXT file) and Microsoft SQL databases • Online evaluation of process value and alarm logs • Evaluation of process value and alarm logs using standard Microsoft tools such as Excel Recipes 1) • Generation of data records for machine data or production data • Display or entry of data records via a configurable screen object or via process screens distributed within the project • Transmission of data records from or to the controller • Import/export of data records from/to CSV files for further processing with other tools (e.g. MS Excel) 1) Option for SIMATIC WinCC Runtime Advanced, runtime licenses must be purchased separately. For further information, refer to "WinCC options". Documentation of process data, alarm events, and recipes • Time or event-driven report output • User-definable layout Flexible expansion of integrated system function using Visual Basic script Language support for multilingual projects • Up to 32 online languages • Language-dependent texts and graphics • Language selection during runtime © Siemens AG 2013 HMI Software SIMATIC WinCC (TIA Portal) Runtime WinCC Runtime Advanced ■ Function (continued) User-oriented access protection according to requirements of regulated sectors • Authentication with user ID and password • User group-specific rights • Central system-wide user administration based on SIMATIC Logon1) • Monitoring of changes by operators in runtime operation1) • Recording of operator actions in an Audit Trail 1) Onboard controller connection to many different controllers • Communication via native drivers and standard OPC channel • Simultaneous connection using several protocols: OPC Client and SIMATIC HMI HTTP protocol are additive, i.e. they can be used in conjunction with other controller connections Open communication between HMI systems and with higherlevel systems • OPC server - Use of the visualization system as a data server (OPC Server) for higher-level automation components, e.g. control systems or systems in the office area - OPC-DA-Server: tags, e.g. process values • Communication between HMI systems is established on the basis of Ethernet networks, or via the Intranet/Internet - Read and write access to tags. The WinCC Runtime Advanced or SIMATIC Panels provide other SIMATIC HMI systems or office applications with data (variables) • Sending of e-mails on demand or event-driven - e.g. to maintenance personnel via SMTP server (Simple Mail Transfer Protocol) - The optional use of e-mail/SMS gateways enables access to standard networks (external service provider required) • System diagnostics via device-specific HTML pages; the following functions are available: - Starting and stopping the HMI runtime for maintenance - Remote access to recipe data records, passwords and information specific to the HMI system - Access to the HMI system files via a file explorer - Download of configuration data via the Intranet/Internet - Supplement with own HTML pages WinCC Sm@rtServer for the remote control via the Intranet and Internet 1) • Display and control of process screens on remote PC or Panel • A SIMATIC HMI system can be used to control or monitor another system remotely; entry level for client/server configurations for distributed operator stations or for solutions with head end or control room WinCC ControlDevelopment for extending the functionality by adding own Controls 1) • Development of proprietary VB.net or C# Controls for integration in SIMATIC WinCC Runtime Advanced 1) Option for SIMATIC WinCC Runtime Advanced, runtime licenses must be purchased separately. For further information, refer to "WinCC options". System prerequisites SIMATIC WinCC Runtime Advanced Processor type (min.) 1) All processors of the SIMATIC IPC, Pentium III or processor running at 500 MHz or comparable RAM (min.) 2) 512 MB Free hard disk space 3) 2 GB on system drive "C:" Operating systems 32-bit operating systems • Microsoft Windows XP Professional SP3 • Windows Embedded Standard 2009 (for IPC / IPC2x7D, HMI IPC4x7C only) • Microsoft Windows Server 2003 R2 StdE SP2 • Microsoft Windows Server 2008 StdE SP2 • Microsoft Windows 7 Professional SP1 • Microsoft Windows 7 Enterprise SP1 • Microsoft Windows 7 Ultimate SP1 • Microsoft Windows Embedded Standard 7 SP1 (for IPC / IPC2x7D, HMI IPC4x7C only) 64-bit operating systems • Microsoft Windows 7 Professional SP1 • Microsoft Windows 7 Enterprise SP1 • Microsoft Windows 7 Ultimate SP1 • Microsoft Windows Server 2003 R2 StdE SP2 • Microsoft Windows Server 2008 R2 Standard Edition SP1 DVD-ROM Optical drive 1) In combination with options, more powerful systems may be required 2) The required RAM is determined primarily by the size of the graphics used. 3) Without taking archives into account. In addition to WinCC, Windows also requires space on the hard disk; e.g. free disk space should be available for the swap file. The following formula has proven itself in the past: Size of swap file = 3 x size of RAM. For further information, refer to your Windows documentation. Siemens ST 80 / ST PC · 2013 4/15 4 © Siemens AG 2013 HMI Software SIMATIC WinCC (TIA Portal) Runtime WinCC Runtime Advanced ■ Technical specifications The following tables of system limitations provide assistance in estimating whether a specific project is still within the system limitations for WinCC Runtime Advanced. Logs The stated maximum values are not additive. Number of logs 100 We cannot guarantee proper functioning of configurations that make full use of all system limits on the HMI devices. Number of entries per log (including all log segments) 3) 500 000 In addition to the limitations specified, allowances must be made for restrictions in configuration memory resources. Number of log segments 400 Cyclical trigger for tag logging 1s Number of tags that can be logged per log 6 144 SIMATIC WinCC Runtime Advanced Trends Tags Number of tags in the project 6 144 Number of PowerTags 128 –4 096 Number of elements per array 1 600 Number of local tags 2 048 Alarms 4 SIMATIC WinCC Runtime Advanced Number of trends 800 Text lists and graphics lists Number of graphic lists 500 Number of text lists 500 Number of entries per text or graphic list 3 500 Number of alarm classes 32 Number of graphic objects 2 000 Number of discrete alarms 4 000 Number of text elements 30 000 Number of analog alarms 500 Scripts Length of an alarm in characters 80 Number of scripts Number of process values per alarm 8 Communication Size of the alarm buffer 1 024 Number of connections 8 Number of queued alarm events 500 Number of connections based on "SIMATIC HMI HTTP" 16 Number of screens 500 4 4) Number of fields per screen 400 Maximum number of connected Sm@rtClients (including a service client) Number of tags per screen 400 Help system Number of complex objects per screen1) 40 Number of characters in a help text Screens 320 Languages Recipes Number of recipes 999 Number of elements per recipe 2) 2 000 User data length in KB per data record 256 Number of data records per recipe 5 000 4/16 200 Siemens ST 80 / ST PC · 2013 Number of runtime languages 32 Scheduler Time-triggered tasks 5) 48 User administration Number of user groups 50 Number of user rights 32 Number of users 100 1) Complex objects are: Bars, sliders, symbol library, clock, and all objects from the Controls area. 2) When using arrays, each array element represents a recipe element 3) For the "segmented circular log" logging method, the number of entries for all sequence logs is valid. The product derived from the number of circular logs times the number of data records in this log may not be exceeded. 4) Up to three Sm@rtClients can interconnect with the Sm@rtServer on Panel PC 477. 5) Event-triggered tasks are not relevant for the system limits. © Siemens AG 2013 HMI Software SIMATIC WinCC (TIA Portal) Runtime WinCC Runtime Advanced ■ Ordering data Order No. Order No. Basic Packages Online software delivery (OSD) 2) SIMATIC WinCC Runtime Advanced V12 SP1 Single license, software and license key download. E-mail address required for the delivery. • WinCC Runtime Advanced 128 PowerTags to WinCC Runtime Professional 128 PowerTags • WinCC Runtime Advanced 512 PowerTags to WinCC Runtime Professional 512 PowerTags • WinCC Runtime Advanced 2048 PowerTags to WinCC Runtime Professional 2048 PowerTags • WinCC Runtime Advanced 4096 PowerTags to WinCC Runtime Professional 4096 PowerTags Software and documentation on DVD, including options software 1) Single license, license key on USB stick • 128 PowerTags • 512 PowerTags • 2048 PowerTags • 4096 PowerTags 6AV2104-0BA02-0AA0 6AV2104-0DA02-0AA0 6AV2104-0FA02-0AA0 6AV2104-0HA02-0AA0 Online software delivery (OSD) 2) Single license, software and license key download. E-mail address required for the delivery. • 128 PowerTags • 512 PowerTags • 2048 PowerTags • 4096 PowerTags 6AV2104-0BA02-0AH0 6AV2104-0DA02-0AH0 6AV2104-0FA02-0AH0 6AV2104-0HA02-0AH0 Powerpacks SIMATIC WinCC Runtime Advanced V12 (without version change) Single license, license key only on USB stick for PowerTags from • 128 PowerTags to 512 PowerTags • 512 PowerTags to 2048 PowerTags • 2048 PowerTags to 4096 PowerTags 6AV2104-2BD02-0BD0 6AV2104-2DF02-0BD0 6AV2104-2FH02-0BD0 Online software delivery (OSD) 2) Single license, software and license key download. E-mail address required for the delivery. • 128 PowerTags to 512 PowerTags • 512 PowerTags to 2048 PowerTags • 2048 PowerTags to 4096 PowerTags 6AV2104-2BD02-0BJ0 6AV2104-2DF02-0BJ0 6AV2104-2FH02-0BJ0 6AV2105-2DD02-0AJ0 6AV2105-2FF02-0AJ0 6AV2105-2HH02-0AJ0 6AV2105-2BB12-0AC0 4 6AV2105-2DD12-0AC0 6AV2105-2FF12-0AC0 6AV2105-2HH12-0AC0 Upgrades SIMATIC WinCC Runtime Advanced V12 to SIMATIC WinCC Runtime Professional V12 SP1 Single license, software and documentation on DVD, license key on USB stick for PowerTags from • WinCC Runtime Advanced 128 PowerTags to WinCC Runtime Professional 128 PowerTags • WinCC Runtime Advanced 512 PowerTags to WinCC Runtime Professional 512 PowerTags • WinCC Runtime Advanced 2048 PowerTags to WinCC Runtime Professional 2048 PowerTags • WinCC Runtime Advanced 4096 PowerTags to WinCC Runtime Professional 4096 PowerTags SIMATIC WinCC Runtime Advanced to SIMATIC WinCC Runtime Professional ASIA V12 SP1 • SIMATIC WinCC Runtime Professional Powerpack Runtime Advanced 128 PowerTags -> Runtime Professional 128 PowerTags ASIA V12 SP1 • SIMATIC WinCC Runtime Professional Powerpack Runtime Advanced 512 PowerTags -> Runtime Professional 512 PowerTags ASIA V12 SP1 • SIMATIC WinCC Runtime Professional Powerpack Runtime Advanced 2048 PowerTags -> Runtime Professional 2048 PowerTags ASIA V12 SP1 • SIMATIC WinCC Runtime Professional Powerpack Runtime Advanced 4096 PowerTags -> Runtime Professional 4096 PowerTags ASIA V12 SP1 6AV2105-2BB02-0AJ0 WinCC V11 to WinCC V12 SP1 SIMATIC WinCC Runtime Advanced V11 to SIMATIC WinCC Runtime Advanced V12 SP1 6AV2105-2BB02-0AC0 6AV2105-2DD02-0AC0 6AV2105-2FF02-0AC0 6AV2105-2HH02-0AC0 Software and documentation on DVD, including options software Single license, license keys on USB stick for • SIMATIC WinCC Runtime Advanced 128 PowerTags V12 SP1 Upgrade V11 -> V12 SP1 • SIMATIC WinCC Runtime Advanced 512 PowerTags V12 SP1 Upgrade V11 -> V12 SP1 • SIMATIC WinCC Runtime Advanced 2048 PowerTags V12 SP1 Upgrade V11 -> V12 SP1 • SIMATIC WinCC Runtime Advanced 4096 PowerTags V12 SP1 Upgrade V11 -> V12 SP1 6AV2104-3BB02-0AE0 6AV2104-3DD02-0AE0 6AV2104-3FF02-0AE0 6AV2104-3HH02-0AE0 1) Runtime licenses for WinCC flexible Runtime Advanced options must be purchased separately for each target system 2) Current information and availability regarding the new delivery package can be found at: http://www.siemens.com/tia-online-software-delivery Siemens ST 80 / ST PC · 2013 4/17 © Siemens AG 2013 HMI Software SIMATIC WinCC (TIA Portal) Runtime WinCC Runtime Advanced ■ Ordering data Order No. Online software delivery (OSD) 2) Single license, software and license key download. E-mail address required for the delivery. • SIMATIC WinCC Runtime Advanced 128 PowerTags V12 SP1 Upgrade V11 -> V12 SP1 • SIMATIC WinCC Runtime Advanced 512 PowerTags V12 SP1 Upgrade V11 -> V12 SP1 • SIMATIC WinCC Runtime Advanced 2048 PowerTags V12 SP1 Upgrade V11 -> V12 SP1 • SIMATIC WinCC Runtime Advanced 4096 PowerTags V12 SP1 Upgrade V11 -> V12 SP1 6AV2104-3BB02-0AK0 6AV2104-3DD02-0AK0 6AV2104-3FF02-0AK0 6AV2104-3HH02-0AK0 SIMATIC WinCC flexible 2008 to SIMATIC WinCC Runtime Advanced V12 SP1 4 6AV2107-4XP00-0BF0 Online software delivery (OSD) 2) Upgrades WinCC flexible 2008 to WinCC V12 SP1 Software and documentation on DVD, including options software single license, license keys on USB stick for • WinCC flexible 2008 Runtime 128 PowerTags to WinCC Runtime Advanced 128 PowerTags 1) • WinCC flexible 2008 Runtime 512 PowerTags to WinCC Runtime Advanced 512 PowerTags 1) • WinCC flexible 2008 Runtime 2048 PowerTags to WinCC Runtime Advanced 2048 PowerTags 1) • WinCC flexible 2008 Runtime 4096 PowerTags to WinCC Runtime Advanced 4096 PowerTags 1) Order No. SIMATIC WinCC flexible Panel Options to SIMATIC WinCC V11 / V12 Panel Options • WinCC flexible /Audit for SIMATIC Panels to SIMATIC WinCC Audit for SIMATIC Panels • WinCC flexible /Sm@rtAccess for SIMATIC Panel to SIMATIC WinCC Sm@rtServer for SIMATIC Panels • WinCC flexible /Sm@rtService for SIMATIC Panels to SIMATIC WinCC Sm@rtServer for SIMATIC Panels 6AV2104-4BB02-0AE0 6AV2104-4DD02-0AE0 Single license, license key download only. E-mail address required for the delivery. SIMATIC WinCC flexible Panel Options to SIMATIC WinCC V11 / V12 Panel Options • WinCC flexible /Audit for SIMATIC Panels to SIMATIC WinCC Audit for SIMATIC Panels • WinCC flexible /Sm@rtAccess for SIMATIC Panel to SIMATIC WinCC Sm@rtServer for SIMATIC Panels • WinCC flexible /Sm@rtService for SIMATIC Panels to SIMATIC WinCC Sm@rtServer for SIMATIC Panels 6AV2107-4XP00-0BK0 6AV2104-4FF02-0AE0 6AV2104-4HH02-0AE0 Online software delivery (OSD) 2) Single license, software and license key download. E-mail address required for the delivery. • WinCC flexible 2008 Runtime 128 PowerTags to WinCC Runtime Advanced 128 PowerTags 1) • WinCC flexible 2008 Runtime 512 PowerTags to WinCC Runtime Advanced 512 PowerTags 1) • WinCC flexible 2008 Runtime 2048 PowerTags to WinCC Runtime Advanced 2048 PowerTags 1) • WinCC flexible 2008 Runtime 4096 PowerTags to WinCC Runtime Advanced 4096 PowerTags 1) 6AV2104-4BB02-0AK0 6AV2104-4DD02-0AK0 6AV2104-4FF02-0AK0 6AV2104-4HH02-0AK0 ■ More information Further information can be found in the Internet at: http://www.siemens.com/tia-portal 4/18 Siemens ST 80 / ST PC · 2013 1) Each including 1 upgrade license to the WinCC Runtime Advanced options 2) Current information and availability regarding the new delivery package can be found at: http://www.siemens.com/tia-online-software-delivery © Siemens AG 2013 HMI Software SIMATIC WinCC (TIA Portal) Runtime WinCC Runtime Professional ■ Overview PC-based operator control and monitoring system for visualization and operator control of processes, production flows, machines and plants in all sectors – from the simple single-user station through to distributed multi-user systems and crosslocation solutions with web clients. SIMATIC WinCC Runtime Professional is the information hub for corporation-wide vertical integration. SIMATIC WinCC Runtime Professional is configured with the SIMATIC WinCC Professional configuration software. ■ Benefits • Functions for all visualization tasks: - Operator functions - Graphics and trend displays - Alarm logging - Report system - Archiving (option) - Recipe management (option) • Universally scalable - Expandable from single station to client-server configurations - Process visualization via the web with the WinCC WebNavigator • Open standards for easy integration - Efficient real-time database MS SQL Server - Open for application modules with ActiveX controls - Visual Basic for Applications for individual expansions - OPC for cross-vendor communication • Part of the Totally Integrated Automation Portal - Direct access to the tag and message configuration of the SIMATIC controller - Excellent support of the new SIMATIC S7-1500 controller With symbolic addressing Access to the new memory-optimized data blocks New alarm and diagnostics concept - Integrated diagnostic functions for increasing productivity ■ Application SIMATIC WinCC Runtime Professional is designed for visualization and operation of processes, manufacturing cycles, machines and plants. With its powerful process interface, especially to the SIMATIC family, and the secure data logging, WinCC Runtime Professional enables solutions for the process control. The sector-neutral basic system enables universal usage in all automation applications. SIMATIC WinCC Runtime Professional can be used in combination with the following HMI devices: SIMATIC PCs: • SIMATIC Panel PC: HMI IPC477C, IPC477D, Panel PC 577B, HMI IPC577C, Panel PC 677B, HMI IPC677C • SIMATIC Box PC: IPC427C, IPC427D, Box PC 627B, IPC627C, IPC827C • SIMATIC Rack PC: Rack PC 547B, IPC547C, IPC547D, Rack PC 647B, IPC647C, Rack PC 847B, IPC847C • Standard PC ■ Design SIMATIC WinCC Runtime Professional is available as a software package with 128, 512, 2 048, 4 096, 8 192, 65 536 PowerTags. PowerTags are data points that are connected to controllers or other data sources via a WinCC Runtime Professional channel. Up to 32 alarms can be obtained from one data point. Moreover, internal tags without coupling are available for additional system performance. WinCC Runtime Professional also contains 500 archive tags. Additional archive licenses can be obtained for greater quantity structures. Licenses for a multi-user configuration The system software with the required number of PowerTags and additionally the SIMATIC WinCC Server for Runtime Professional option must be installed on the server. For the clients in the basic configuration, a SIMATIC WinCC Client for Runtime Professional license is sufficient. ■ Function Visualization via Windows-compliant user interface Made up of parameterizable screen objects and faceplates created on a project-specific basis: • Numeric and alphanumeric input/output fields • Static text and graphic display plus vector graphics • Dynamizable graphics from HMI symbol library • Bar graph, trend curve graph with scroll and zoom function as well as read line • Signal-specific text and graphic lists • Buttons and switches for operator-process communication • Editing fields for process values (signals) • Analog display, slider as example for further screen objects • Project-specific faceplates created from basic objects of the system • Graphic displays for various standard graphic formats, e.g. bitmaps, .jpg, .wmf Alarms and messages • Discrete alarms and analog alarms, as well as event-driven Alarm-S/Alarm-D message procedure with SIMATIC S7 • The new alarm and diagnostics concept of the S7-1500 controller is also supported • Freely-definable alarm classes for definition of acknowledgment response and display of alarm events Logging of alarms and process values 1) • Signaling system for detecting and archiving events with display and control options according to DIN 19235 • Process logging for the acquisition, compression and storage of measured values • Online evaluation of process value and alarm logs 1) Option for SIMATIC WinCC Runtime Professional; runtime licenses must be purchased separately. For further information, refer to "WinCC options". Siemens ST 80 / ST PC · 2013 4/19 4 © Siemens AG 2013 HMI Software SIMATIC WinCC (TIA Portal) Runtime WinCC Runtime Professional ■ Function (continued) Recipes 1) • Generation of data records for machine data or production data • Display or entry of data records via a configurable screen object or via process screens distributed within the project • Transmission of data records from or to the controller • Import/export of data records for further processing with other tools (e.g. MS Excel) Documentation of process data, alarm events, and recipes • Time or event-driven report output • User-definable layout Flexible expansion by means of Visual Basic Script and ANSI-C • Programming interfaces for individual access to data and functions of WinCC Runtime Professional and for the integration in user programs with VBA, VB Script, C-API, C-Script (ANSI-C) Language support for multilingual projects • Language-dependent texts and graphics • Language selection during runtime 4 Onboard controller connection to many different controllers • Communication via native drivers and standard OPC channel • For communication with subordinate controls (SIMATIC protocols, PROFIBUS DP, PROFIBUS FMS, DDE and OPC server included in the scope of delivery) Open communication between HMI systems and with higher-level systems • OPC-Server Use of the visualization system as a data server (OPC-Server) for higher-level automation components such as control systems or systems in the office sector - OPC-DA-Server: tags, e.g. process values - OPC-HDA-Server: logged process values - OPC-A&E-Server: Alarms - OPC-XML-DA-Server: tags, e.g. process values - OPC-UA-DA-Server: tags, e.g. process values • OLE DB Server - Standardized and user-friendly access to WinCC log data (MS SQL Server 2005). - Access is via the OLE-DB Provider supplies all WinCC log data available along with the accompanying process values, as well as alarm and user texts. - The WinCC OLE-DB provider also supports analysis functions such as minimum, maximum, alarm hit list, etc. • WinCC WebNavigator for Runtime Professional 1) - Option for SIMATIC WinCC Runtime Professional for operating and monitoring plants over the Internet, company Intranet or LAN. - Configuration from a web server with the SIMATIC WinCC Runtime Professional software as a single-user, client or server version and a web client that enables operator control and monitoring of a current WinCC Runtime Professional project via an Internet browser with ActiveX support. The WinCC basic system does not have to be installed on the client computer. • WinCC DataMonitor for Runtime Professional 1) - The WinCC DataMonitor is used for displaying and evaluating current process states and historical data on office PCs using standard tools such as Microsoft Internet Explorer or Microsoft Excel. The DataMonitor Client is supported by a web server with current and historic process data and alarms. All staff ranging from machine operators to corporate managers can use the DataMonitor to obtain information. 1) 4/20 Siemens ST 80 / ST PC · 2013 Option for SIMATIC WinCC Runtime Professional; runtime licenses must be purchased separately. For further information, refer to "WinCC options". © Siemens AG 2013 HMI Software SIMATIC WinCC (TIA Portal) Runtime WinCC Runtime Professional ■ Function (continued) ■ Integration WinCC ControlDevelopment for extending the functionality by adding own Controls 1) • Development of proprietary VB.net or C# Controls for integration in WinCC Runtime Professional 1) Option for SIMATIC WinCC Runtime Professional; runtime licenses must be purchased separately. For further information, refer to "WinCC options". System prerequisites SIMATIC WinCC Runtime Professional Processor type (min.) 1) • Windows XP: 2.5 GHz P4 or comparable, Pentium M, 1.6 GHz or comparable • Windows 7 (32-bit): 3.5 GHz P4 or comparable, dual core • Windows Server 2003: 3 GHz P4 or comparable • Windows Server 2008: 3 GHz P4 or comparable, dual/multi core RAM (min.) 2) 2 GB Free hard disk space 3) 2 GB on system drive "C:" Operating systems 32-bit operating systems • Microsoft Windows XP Professional SP3 • Windows Embedded Standard 2009 (for IPC / IPC2x7D, HMI IPC4x7C only) • Microsoft Windows Server 2003 R2 StdE SP2 • Microsoft Windows Server 2008 StdE SP2 • Microsoft Windows 7 Professional SP1 • Microsoft Windows 7 Enterprise SP1 • Microsoft Windows 7 Ultimate SP1 • Microsoft Windows Embedded Standard 7 SP1 (for IPC / IPC2x7D, HMI IPC4x7C only) Integration in company-wide solutions (IT and business integration) WinCC Runtime Professional is strictly based on Microsoft technology, which provides for the greatest possible compatibility and integration ability. ActiveX and .net Controls support technology and sector-specific expansions. Cross-manufacturer communication is also a simply exercise. The reason: WinCC Runtime Professional can be used as an OPC client and server, and in addition to access to current process values, it also supports standards such as OPC HDA (Historical Data Access), OPC Alarm & Events, OPC UA Data Access and OPC XML Data Access. Just as important: Visual Basic Scripting (VBS) as an easy-to-learn, open Runtime language. If desired, professional application developers can also use ANSI-C. WinCC Runtime Professional integrates a powerful and scalable Historian function based on the Microsoft SQL Server in the basic system. Thus the user is given all possibilities: from high-performance archiving of current process data, to long-term archiving with high data compression, through to a central information turntable in form of a company-wide Process Historian. Open interfaces form the basis for an effective IT and business integration. 64-bit operating systems • Microsoft Windows 7 Professional SP1 • Microsoft Windows 7 Enterprise SP1 • Microsoft Windows 7 Ultimate SP1 • Microsoft Windows Server 2003 R2 StdE SP2 • Microsoft Windows Server 2008 R2 Standard Edition SP1 Graphics card 32 MB RAM, 24 bit color depth Network Ethernet 10 Mbit/s or higher Optical drive DVD-ROM 1) In combination with options, more powerful systems may be required 2) The required RAM is determined primarily by the size of the graphics used. 3) Without taking archives into account. Note: In addition to WinCC, Windows also requires space on the hard disk; e.g. free disk space should be available for the swap file. The following formula has proven itself in the past: Size of swap file = 3 x size of RAM. For further information, refer to your Windows documentation. Siemens ST 80 / ST PC · 2013 4/21 4 © Siemens AG 2013 HMI Software SIMATIC WinCC (TIA Portal) Runtime WinCC Runtime Professional ■ Technical specifications The following tables of system limits provide assistance in estimating whether a specific project is still within the system limitations for WinCC Runtime Professional. The stated maximum values are not additive. We cannot guarantee proper functioning of configurations that make full use of all system limits on the HMI devices. In addition to the limitations specified, allowances must be made for restrictions in configuration memory resources. SIMATIC WinCC Runtime Professional Alarms Logs Trend views per screen 25 Trends per trend view 80 Tables per screen 25 Columns per table 12 Values per table 30 000 Logs per single-user station/server 100 Log tags per single-user station/ server 7) 8 000 Configurable alarms per server/single user 20 000 PowerTags per alarm line 10 Trend views per image 25 User text blocks per alarm line 10 Trends per trend view 80 Alarm classes (incl. system alarm classes) 18 User administration Number of user groups 128 Alarm types 16 Number of user rights 999 Alarm priorities 17 (0...16) Number of users 128 Alarms per alarm log Unlimited 1) Configurations – Quantity structure in a multi-user system Alarms per short-term log list 1 000 WinCC clients in a system 32 8) 9) Alarms per long-term log list 1 000 2) Web clients in a system 50 10) Alarms per alarm display 5 000 3) Trends Alarms in Runtime 4 SIMATIC WinCC Runtime Professional Screens Objects per screen 4) 3 0005) Levels per screen 32 Screens per project 1 000 5) Instances of fixed faceplates in a process screen 31 instances of the same picture type Screen size in pixels 10 000 x 10 000 Nesting levels of screen objects 20 Recipes 000 5) Number of recipes 1 Number of recipe elements 500 6) Number of recipe data records 3 000 6) Number of views 4/22 Unlimited Siemens ST 80 / ST PC · 2013 5) 1) Limited by system resources. 2) On single-user station or server or on client per server if "LongTimeArchiveConsistency" is set to "No". On single-user station, server, or client if "LongTimeArchiveConsistency" is set to "Yes". 3) On single-user station or server or on client per server. 4) The number and complexity of the objects affect the performance. 5) Limited by system resources. 6) The sum of the number of recipe elements and number of data records must not exceed a value of 320,000. 7) Dependent on the Logging Powerpack used for the log tags. 500 log tags are contained in the basis version. 8) If the server is also used as an operating unit, the number of clients for this server is reduced to four. 9) Mixed configuration: 32 Clients + 3 Web Clients 10) Mixed configuration: 50 Web Clients + 1 WinCC Client © Siemens AG 2013 HMI Software SIMATIC WinCC (TIA Portal) Runtime WinCC Runtime Professional ■ Ordering data Order No. Order No. Basic software Powerpacks SIMATIC WinCC Runtime Professional V12 SP1 SIMATIC WinCC Runtime Professional V12 and SIMATIC WinCC Runtime Professional ASIA V12 For PC systems; incl. software options 1), language/script versions: DE, EN, FR, IT, ES Single License, on DVD incl. licensing, on USB stick, for: • 128 PowerTags • 512 PowerTags • 2048 PowerTags • 4096 PowerTags • 8192 PowerTags • 65535 PowerTags 6AV2105-0BA02-0AA0 6AV2105-0DA02-0AA0 6AV2105-0FA02-0AA0 6AV2105-0HA02-0AA0 6AV2105-0KA02-0AA0 6AV2105-0MA02-0AA0 Incl. 500 archive tags each Online software delivery (OSD) 3) Single license, software and license key download. E-mail address required for the delivery. • 128 PowerTags • 512 PowerTags • 2048 PowerTags • 4096 PowerTags • 8192 PowerTags • 65535 PowerTags 6AV2105-0BA02-0AH0 6AV2105-0DA02-0AH0 6AV2105-0FA02-0AH0 6AV2105-0HA02-0AH0 6AV2105-0KA02-0AH0 6AV2105-0MA02-0AH0 Incl. 500 archive tags each SIMATIC WinCC Runtime Professional ASIA V12 SP1 For PC systems; incl. software options 1), language/script versions: EN, CHs, CHt, KOR, JPN Single License, on DVD incl. licensing, for: • 128 PowerTags • 512 PowerTags • 2048 PowerTags • 4096 PowerTags • 8192 PowerTags • 65535 PowerTags 6AV2105-0BA12-0AA0 6AV2105-0DA12-0AA0 6AV2105-0FA12-0AA0 6AV2105-0HA12-0AA0 6AV2105-0KA12-0AA0 6AV2105-0MA12-0AA0 Incl. 500 archive tags each SIMATIC WinCC Client for Runtime Professional • WinCC Client for Runtime Professional • WinCC Client for Runtime Professional (form of delivery OSD 3)) • WinCC Client for Runtime Professional ASIA 6AV2107-0DB02-0AA0 6AV2107-0DB02-0AH0 6AV2107-0DB12-0AA0 1) Runtime licenses for WinCC Runtime Professional options must be purchased separately for each target system. 2) Each including 1 upgrade license to the WinCC Runtime Professional options. 3) Current information and availability regarding the new delivery package can be found at: http://www.siemens.com/tia-online-software-delivery Single license, license key only on USB sticks for PowerTags from • 128 to 512 PowerTags • 512 to 2048 PowerTags • 2048 to 4096 PowerTags • 4096 to 8192 PowerTags • 8192 to 65536 PowerTags 6AV2105-2BD02-0BD0 6AV2105-2DF02-0BD0 6AV2105-2FH02-0BD0 6AV2105-2HK02-0BD0 6AV2105-2KM02-0BD0 Online software delivery (OSD) 3) Single license, license key download only. E-mail address required for the delivery. • 128 to 512 PowerTags • 512 to 2048 PowerTags • 2048 to 4096 PowerTags • 4096 to 8192 PowerTags • 8192 to 65536 PowerTags 6AV2105-2BD02-0BJ0 6AV2105-2DF02-0BJ0 6AV2105-2FH02-0BJ0 6AV2105-2HK02-0BJ0 6AV2105-2KM02-0BJ0 Upgrades WinCC V11 to WinCC V12 SP1 SIMATIC WinCC Runtime Professional V11 to SIMATIC WinCC Runtime Professional V12 SP1 and SIMATIC WinCC Runtime Professional ASIA V11 to SIMATIC WinCC Runtime Professional ASIA V12 SP1 Single license, on DVD incl. licensing on USB stick • SIMATIC WinCC Runtime Professional 128 PowerTags V12 SP1 Upgrade V11 -> V12 SP1 • SIMATIC WinCC Runtime Professional 512 PowerTags V12 SP1 Upgrade V11 -> V12 SP1 • SIMATIC WinCC Runtime Professional 2048 PowerTags V12 SP1 Upgrade V11 -> V12 SP1 • SIMATIC WinCC Runtime Professional 4096 PowerTags V12 SP1 Upgrade V11 -> V12 SP1 • SIMATIC WinCC Runtime Professional 8192 PowerTags V12 SP1 Upgrade V11 -> V12 SP1 • SIMATIC WinCC Runtime Professional 65536 PowerTags V12 SP1 Upgrade V11 -> V12 SP1 4 6AV2105-3BB02-0AE0 6AV2105-3DD02-0AE0 6AV2105-3FF02-0AE0 6AV2105-3HH02-0AE0 6AV2105-3KK02-0AE0 6AV2105-3MM02-0AE0 Siemens ST 80 / ST PC · 2013 4/23 © Siemens AG 2013 HMI Software SIMATIC WinCC (TIA Portal) Runtime WinCC Runtime Professional ■ Ordering data 4 Order No. Order No. Upgrades WinCC V11 to WinCC V12 SP1 (continued) Upgrades WinCC V7 to WinCC V12 SP1 (continued) Online software delivery (OSD) 2) SIMATIC WinCC V7.0 to SIMATIC WinCC Runtime Professional V12 SP1 and SIMATIC WinCC V7.0 ASIA to SIMATIC WinCC Runtime Professional ASIA V12 SP1 • WinCC V7.0 Runtime 2048 PowerTags to WinCC Runtime Professional 2048 PowerTags V12 SP1 1) • WinCC V7.0 Runtime 8192 PowerTags to WinCC Runtime Professional 8192 PowerTags V12 SP1 1) • WinCC V7.0 Runtime 65536 PowerTags to WinCC Runtime Professional 65536 PowerTags V12 SP1 1) • WinCC V7.0 RC/RT128 / RC/RT Client to WinCC Client for Runtime Professional V12 SP1 Single license, software and license key download. E-mail address required for the delivery. • SIMATIC WinCC Runtime Professional 128 PowerTags V12 SP1 Upgrade V11 -> V12 SP1 • SIMATIC WinCC Runtime Professional 512 PowerTags V12 SP1 Upgrade V11 -> V12 SP1 • SIMATIC WinCC Runtime Professional 2048 PowerTags V12 SP1 Upgrade V11 -> V12 SP1 • SIMATIC WinCC Runtime Professional 4096 PowerTags V12 SP1 Upgrade V11 -> V12 SP1 • SIMATIC WinCC Runtime Professional 8192 PowerTags V12 SP1 Upgrade V11 -> V12 SP1 • SIMATIC WinCC Runtime Professional 65536 PowerTags V12 SP1 Upgrade V11 -> V12 SP1 6AV2105-3BB02-0AK0 6AV2105-3DD02-0AK0 6AV2105-3FF02-0AK0 6AV2105-3HH02-0AK0 6AV2105-3KK02-0AK0 6AV2105-3MM02-0AK0 Upgrades WinCC V7 to WinCC V12 SP1 SIMATIC WinCC V7.0 to SIMATIC WinCC Runtime Professional V12 SP1 and SIMATIC WinCC V7.0 ASIA to SIMATIC WinCC Runtime Professional ASIA V12 SP1 Single license, on DVD incl. licensing on USB stick • WinCC V7.0 Runtime 128 PowerTags to WinCC Runtime Professional 128 PowerTags V12 SP1 1) • WinCC V7.0 Runtime 512 PowerTags to WinCC Runtime Professional 512 PowerTags V12 SP1 1) 6AV2105-4BB02-0AE0 6AV2105-4DD02-0AE0 6AV2105-4FF02-0AE0 ■ More information Further information can be found in the Internet at: http://www.siemens.com/tia-portal 4/24 Siemens ST 80 / ST PC · 2013 6AV2105-4KK02-0AE0 6AV2105-4MM02-0AE0 6AV2107-4DB02-0AE0 6AV2105-4BB02-0AE0 Online software delivery (OSD) 2) Single license, software and license key download. E-mail address required for the delivery. • WinCC V7.0 Runtime 128 PowerTags to WinCC Runtime Professional 128 PowerTags V12 SP1 1) • WinCC V7.0 Runtime 512 PowerTags to WinCC Runtime Professional 512 PowerTags V12 SP1 1) • WinCC V7.0 Runtime 2048 PowerTags to WinCC Runtime Professional 2048 PowerTags V12 SP1 1) • WinCC V7.0 Runtime 8192 PowerTags to WinCC Runtime Professional 8192 PowerTags V12 SP1 1) • WinCC V7.0 Runtime 65536 PowerTags to WinCC Runtime Professional 65536 PowerTags V12 SP1 1) • WinCC V7.0 RC/RT128 / RC/RT Client to WinCC Client for Runtime Professional V12 SP1 6AV2105-4BB02-0AK0 6AV2105-4DD02-0AK0 6AV2105-4FF02-0AK0 6AV2105-4KK02-0AK0 6AV2105-4MM02-0AK0 6AV2107-4DB02-0AK0 1) Each including 1 upgrade license to the WinCC Runtime Professional options. 2) Current information and availability regarding the new delivery package can be found at: http://www.siemens.com/tia-online-software-delivery © Siemens AG 2013 HMI Software SIMATIC WinCC (TIA Portal) Runtime WinCC Runtime Communication ■ Overview Communication – SIMATIC WinCC Runtime Advanced Protocol WinCC Advanced is an open visualization system and offers the option of connecting the most diverse control systems. Third-party controllers (from WinCC V11.0) 3) Number of connectable controllers Current notes and information about OPC servers from many different suppliers can be found at: http://www.opcfoundation.org/ WinCC Advanced supports the standards: • OPC Data Access 2.05a • OPC UA Data Access 1.01 • OPC XML Data Access 1.00 (client via DCOM/XML gateway) Protocol Description PC interface Channel for communication with max. 4 x Allen Bradley controllers via Ethernet TCP/IP with Allen Bradley Ethernet IP protocol The controllers ControlLogix / CompactLogix, SLC500 / MicroLogix and PLC5 are supported CP 1612 A2 Allen Bradley DF1 Channel for communication with Allen Bradley controllers via DF1 protocol The controllers SLC500 / MicroLogix and PLC5 are supported 3) COM1/COM2 Mitsubishi MC TCP/IP Channel for communication with max. 4 x Mitsubishi controllers via Ethernet TCP/IP with Mitsubishi MC TCP/IP protocol The FX3, Q, and iQ/QnUD controller series are supported CP 1612 A2 Mitsubishi FX Channel for communication with Mitsubishi controllers via FX protocol The FX1N, FX2N controllers are supported COM1/COM2 HTTP communication for data exchange between SIMATIC HMI (client + server) 1) CP 1612 A2 Modbus TCP/IP Channel for communication with max. 4 x Modicon controllers via Ethernet TCP/IP using the Modbus TCP/IP protocol The Quantum, Momentum, Premium, TSX Micro, Compact and M340 controllers are supported CP 1612 A2 Channel for communication via Ethernet TCP/IP with max. 8 x SIMATIC S7 controllers S7-1200, S7-1500 S7-300, S7-400, S7-200 with CP 243-1 CP 1612 A2 CP 1613 A2 CP 1623 Modbus RTU Channel for communication with Modicon controllers via the Modbus RTU protocol The Quantum, Momentum, and Compact controllers are supported COM1/COM2 Channel for communication via MPI, PROFIBUS with max. 8 x SIMATIC S7 controllers S7-1200 with CM 1243-5 (DP master), S7-1500 S7-300, S7-400 S7-200 (only passive S7-200) CP 5611 A2 CP 5621 CP 5512 CP 5711 CP 5613 A2 CP 5623 Omron Link / Multi Link Channel for communication with Omron controllers via the Link/Multi protocol The CP1x, CJ1x, CJ2H, CS1x, and CP2MC controllers are supported COM1/COM2 Channel for communication via PPI with 1 x SIMATIC S7-200 (network operation, e.g. parallel PG possible) CP 5611 A2 CP 5621 CP 5512 CP 5711 CP 5613 A2 CP 5623 OPC client 1) 4) for OPC DA, OPC UA DA, XML DA Channel for OPC communication, WinCC can acquire data from OPC server applications CP 1612 A2 OPC server for OPC DA Server applications for OPC communication; WinCC provides process data to OPC clients CP 1612 A2 SIMATIC HMI Ethernet TCP/IP (HTTP communication) SIMATIC S7 Ethernet TCP/IP (S7 communication) MPI, PROFIBUS (S7 communication) PPI (PPI protocol) Software interface (S7 communication) Channel for communication via software interface with WinAC Cross-manufacturer SINUMERIK 2) Ethernet TCP/IP (S7 communication) Channel for communication via Ethernet TCP/IP with SINUMERIK 840D sl CP 1612 A2 CP 1613 A2 CP 1623 MPI (S7 communication) Channel for communication via MPI with SINUMERIK 840D sl CP 5611 A2 CP 5621 CP 5512 CP 5711 CP 5613 A2 CP 5623 PC interface Allen Bradley Ethernet IP WinCC Advanced permits the parallel coupling of up to 8 controllers. Connection to third-party controllers The following "Coupling overview" table lists third-party protocols and controllers which are directly supported by WinCC Advanced. Generally it is also possible to connect third-party controllers via OPC (OLE for Process Control). Description 1) HTTP and OPC communication can be used in combination with the other couplings; regarding SIMATIC Panels that support HTTP or OPC communication, see the overview under "System interfaces (WinCC V11)". 2) "SINUMERIK Operate WinCC RT Advanced" license required; for further information, see NC 60 Catalog. 3) For detailed information regarding supported controllers, see "System interfaces (WinCC V11)" 4) Application note: The parallel use of the OPC client channel allows, for example, the connection to an SNMP OPC Server for visualization of the data present there. The SNMP OPC Server enables monitoring of any network components (e.g. switch) that support the SNMP protocol. Further information can be foundunder SIMATIC NET communications systems/SNMP OPC Server. Siemens ST 80 / ST PC · 2013 4/25 4 © Siemens AG 2013 HMI Software SIMATIC WinCC (TIA Portal) Runtime WinCC Runtime Communication ■ Overview (continued) Communication – SIMATIC WinCC Runtime Professional Protocol WinCC Professional is an open process visualization system and offers the option of connecting the most diverse control systems. SIMATIC S7 SIMATIC S7 Released communication software Only communication software with the listed (or higher) product versions should be used. Corresponding SIMATIC NET upgrades are available for the upgrading of older versions. Number of connectable controllers With CP 1613, a maximum of 64 S7 controllers can be connected via Industrial Ethernet; with CP 5611 a maximum of 8 and with CP 5613 a maximum of 44 S7 controllers can be connected via PROFIBUS. With approx. 10 or more controllers, the use of Industrial Ethernet is recommended. Client-server communication Communication between the clients and the server is implemented using the TCP/IP protocol. The construction of a separate PC-LAN is recommended. For small projects with correspondingly small message frame advent, a SIMATIC NET Industrial Ethernet can be used for both process communication (WinCC/server ↔ PLC) and for PC-PC communication (WinCC/client ↔ WinCC/server) 4 Siemens ST 80 / ST PC · 2013 CP 1612 A2 CP 1613 A2 CP 5611 A2 CP 5621 CP 5512 CP 5711 CP 5613 A2 CP 5623 Channel for communication with Allen Bradley controllers via Ethernet TCP/IP with Ethernet IP protocol The controllers ControlLogix / CompactLogix, SLC500 / MicroLogix, and PLC5 are supported CP 1612 A2 Mitsubishi MC TCP/IP Channel for communication with Mitsubishi controllers via Ethernet TCP/IP with Mitsubishi MC TCP/IP protocol The FX3, Q, and iQ/QnUD controller series are supported CP 1612 A2 Modbus TCP/IP Channel for communication with Modicon controllers via Ethernet TCP/IP using the Modbus TCP/ IP protocol The Quantum, Momentum, Premium, TSX Micro, Compact and M340 controllers are supported CP 1612 A2 OPC client 1) for OPC DA, OPC XML DA Channel for OPC communication, WinCC can acquire data from OPC server applications CP 1612 A2 OPC server for OPC DA, OPC UA DA, OPC XML DA, OPC A&E, OPC HDA Server applications for OPC communication; WinCC provides process data to OPC clients CP 1612 A2 Cross-manufacturer 1) 4/26 Protocol Suite with channel units for communication with SIMATIC S7 via • Ethernet TCP/IP (S7 communication) to S7-1200, S7-1500, S7-300, S7-400 • MPI, PROFIBUS (S7 communication) to S7-1200 with CM 1243-5 (DP master), S7-1500, S7-300, S7-400 • Software interface (S7 communication) to Win AC Allen Bradley Ethernet IP Current notes and information about OPC servers from many different suppliers can be found at: http://www.opcfoundation.org/ WinCC Professional supports the standards: • OPC Data Access 2.05a • OPC Data Access 3.00 • OPC UA Data Access 1.01 • OPC XML Data Access 1.00 • OPC HDA 1.20 • OPC A&E 1.10 PC interface Third-party controllers (from WinCC V11.0) Connection to third-party controllers The following "Coupling overview" table lists third-party protocols and controllers which are directly supported by WinCC Professional. Generally it is also possible to connect third-party controllers via OPC (OLE for Process Control). Description Application note: The parallel use of the OPC client channel allows, for example, the connection to an SNMP OPC Server for visualization of the data present there. The SNMP OPC Server enables monitoring of any network components (e.g. switch) that support the SNMP protocol. Further information can be foundunder SIMATIC NET communications systems/SNMP OPC Server. © Siemens AG 2013 HMI Software SIMATIC WinCC (TIA Portal) Runtime WinCC Runtime Communication ■ Overview (continued) Industrial Ethernet SIMATIC S7-400 WinCC Runtime Advanced PROFIBUS SIMATIC S7-1200 *B67B;;B SIMATIC S7-300 WinCC Runtime Advanced single-user system WinCC RT Professional Client 4 WinCC RT Professional Client WinCC RT Professional Client WinCC RT Professional Client Industrial Ethernet WinCC RT Professional Server PROFIBUS SIMATIC S7-400 *B67B;;B SIMATIC S7-400 WinCC Runtime Professional multi-user system with operable Server Siemens ST 80 / ST PC · 2013 4/27 © Siemens AG 2013 HMI Software SIMATIC WinCC (TIA Portal) Runtime WinCC Runtime Communication ■ Overview (continued) OPC Client WinCC RT Professional Industrial Ethernet OPC Server WinCC RT Advanced 4 SIMATIC S7-300 OPC coupling 4/28 Siemens ST 80 / ST PC · 2013 SIMATIC S7-1200 *B67B;;B PROFIBUS © Siemens AG 2013 HMI Software SIMATIC WinCC (TIA Portal) Runtime WinCC Runtime Communication ■ Ordering data Order No. Communication via Industrial Ethernet TCP/IP CP 1612 A2 6GK1161-2AA01 PCI card (32-bit) for connection of a programming device or PC to Industrial Ethernet (10/100/1000 Mbit/s) with RJ45 connection via SOFTNET S7 and SOFTNET PG. For (32-bit) Windows XP Professional, Windows 2003 Server, VISTA Ultimate/Business; for CP 1612; CP 1612 A2 German/English • Single license for 1 installation • Upgrade package for SIMATIC NET from Edition 2006 • Upgrade package for SIMATIC NET V6.0, V6.1, V6.2 and Edition 2005 WinCC Runtime Professional: SOFTNET-S7 Lean (maximum of 8 connections) or SOFTNET-S7 (maximum of 64 connections) must be installed (SOFTNET-S7 Lean is included in the scope of delivery of WinCC Runtime Professional) CP 1613-A2 SOFTNET-S7 Version 8.0 SP1 / Edition 2008 SP2 (V7.1) 6GK1161-3AA01 Software for S7 and S5-compatible communication, incl. PG/OP communication, OPC server and NCM PC; up to 120 connections, single license for 1 installation, runtime software, software and electronic manual on CD-ROM, license key on USB flash drive, Class A For (32-bit) Windows 7 Ultimate, Professional; for CP 1612; CP 1612 A2 German/English (included in the scope of delivery: Edition 2008 SP2 (V7.1) ) 4 Version 8.0 SP1 For (32-bit) Windows 7 Ultimate, Professional; for CP 1613; CP 1613 A2, CP 1623 German/English (included in the scope of delivery: Edition 2008 SP2 (V7.1) ) Edition 2008 SP2 (V7.1) Software for S7-compatible and S5-compatible communication incl. OPC server, PG/OP communication and NCM PC; up to 8 connections; single license for one installation of runtime software, software and electronic manual on CD-ROM; license key on USB stick; Class A 6GK1704-1LW00-3AE1 S7-1613 Version 8.0 SP1 / Edition 2008 SP2 (V7.1) Version 8.0 SP1 (included in the scope of delivery of WinCC V11) 6GK1704-1LW80-3AA0 6GK1704-1LW00-3AE0 PCI card (32 bit) for connecting a PG/PC to Industrial Ethernet (communications software must be ordered separately) Software for S7 and S5-compatible communication, incl. OPC server, PG/OP communication and NCM PC; up to 64 connections, single license for 1 installation, runtime software, software and electronic manual on CD-ROM, license key on USB flash drive, Class A SOFTNET-S7 Lean Version 8.0 SP1 / Edition 2008 SP2 (V7.1) For (32-bit) Windows 7 Ultimate, Professional; for CP 1612; CP 1612 A2 German/English (included in scope of supply: Edition 2008 SP2 (V7.1) ) Edition 2008 SP2 (V7.1) Software requirement: WinCC Runtime Advanced: No further installation is required (SOFTNET-S7) For (32-bit) Windows XP Professional, Windows 2003 Server, VISTA Ultimate/Business; for CP 1612; CP 1612 A2 German/English • Single license for 1 installation • Upgrade package for SIMATIC NET from Edition 2006 • Upgrade package for SIMATIC NET V6.0, V6.1, V6.2 and Edition 2005 Order No. Version 8.0 SP1 Edition 2008 SP2 (V7.1) 6GK1704-1CW80-3AA0 6GK1704-1CW00-3AE0 6GK1704-1CW00-3AE1 For (32-bit) Windows XP Professional, Windows 2003 Server, VISTA Ultimate/Business; for CP 1613; CP 1613 A2, CP 1623 German/English • Single license for 1 installation • Upgrade package for SIMATIC NET from Edition 2006 • Upgrade package for SIMATIC NET V6.0, V6.1, V6.2 and Edition 2005 CP 1623 6GK1716-1CB80-3AA0 6GK1716-1CB00-3AE0 6GK1716-1CB00-3AE1 6GK1162-3AA00 PCI Express X1 card (32-bit) for connection of PG/PC to Industrial Ethernet (communications software to be ordered separately) Siemens ST 80 / ST PC · 2013 4/29 © Siemens AG 2013 HMI Software SIMATIC WinCC (TIA Portal) Runtime WinCC Runtime Communication ■ Ordering data Order No. Communication via PROFIBUS PC adapter USB 6ES7972-0CB20-0XA0 Can be used under Windows XP CP 5611 A2 6GK1561-1AA01 6GK1562-1AA00 6GK1562-1AM00 Software for S7 Communication incl. PG/OP protocol, FDL, OPC server; runtime software, software and electronic manual on CD-ROM, license key on USB flash drive, Class A 6GK1551-2AA00 Version 8.0 SP1 Comprising CP 5621 (32-bit) and MPI cable, 5 m CP 5512 PCMCIA card (CARDBUS 32-bit) for the connection of a PG/notebook to PROFIBUS or MPI (communications software included in WinCC basic package) CP 5711 4 For (32-bit) Windows 7 Ultimate, Professional; for CP 5613 A2, CP 5623 German/English 6GK1571-1AM00 USB adapter for connecting a PG/PC to PROFIBUS or MPI (communications software included in the WinCC basic package) 4/30 6GK1562-3AA00 PCI Express X1 card (32-bit) for connection of PG/PC to Industrial Ethernet (communications software to be ordered separately) S7-5613 Version 8.0 SP1 / Edition 2008 SP2 (V7.1) PCI Express X1 card (32-bit) for connection of PG/PC to PROFIBUS (communications software included in WinCC basic package) CP 5621 MPI 6GK1561-3AA01 PCI card (32-bit) for connecting a PC to PROFIBUS (communications software must be ordered separately). CP 5623 PCI Card (32-bit) for connecting a PG/PC to PROFIBUS (Communication software included in the WinCC basic package) CP 5621 Order No. CP 5613 A2 Siemens ST 80 / ST PC · 2013 For (32-bit) Windows XP Professional, Windows 2003 Server, VISTA Ultimate/Business; for CP 5613 A2, CP 5623 German/English • Single license for 1 installation • Upgrade package for SIMATIC NET from Edition 2006 • Upgrade package for SIMATIC NET V6.0, V6.1, V6.2 and Edition 2005 6GK1713-5CB80-3AA0 6GK1713-5CB00-3AE0 6GK1713-5CB00-3AE1 © Siemens AG 2013 HMI Software SIMATIC WinCC (TIA Portal) options SIMATIC WinCC (TIA Portal) options ■ Overview Options for SIMATIC Panels, SIMATIC WinCC Runtime Advanced and SIMATIC WinCC Runtime Professional SIMATIC WinCC Recipes for SIMATIC WinCC Runtime Advanced and SIMATIC WinCC Runtime Professional • Generation and management of data records for machine or production data • Display or entry of data records via a configurable screen object or via process screens distributed within the project • Transmission of data records from or to the controller • Import/export of data records for further processing with other tools (e.g. MS Excel) SIMATIC WinCC Logging for SIMATIC WinCC Runtime Advanced and SIMATIC WinCC Runtime Professional • Logging of alarms and process values • Online evaluation of process value logs and alarm logs • Evaluation of process value and alarm logs using standard MS tools such as Excel SIMATIC WinCC Audit for SIMATIC Panels and SIMATIC WinCC Runtime Advanced • Recording of operator actions in an Audit Trail • Electronic signature for important operator actions relevant to production • Audit supports users in meeting special quality requirements, e.g. - Production plant requiring validation according to 21 CFR Part 11 (Food Drug Administration law) - In respect of traceability according to EU 175/2002 (EU directive) SIMATIC WinCC Server and SIMATIC WinCC Client for SIMATIC WinCC Runtime Professional For setting up a high-performance client-server system • A number of coordinated HMI stations can be operated in a single group with networked automation systems • Client/server solution: - One server can supply up to 32 connected clients with process and archive data, alarms, screens and reports - Depending on the size of the plant, up to 12 servers and 32 clients can be employed. SIMATIC WinCC WebNavigator for SIMATIC WinCC Runtime Professional • Operator control and monitoring of plants via the Internet or the in-house intranet or LAN • Web Client permits the operator control and monitoring of a current WinCC Runtime Professional project via an Internet browser with ActiveX support. SIMATIC WinCC DataMonitor for SIMATIC WinCC Runtime Professional • Display and analysis of current process states and historical data on office PCs with standard tools. • Information can be compiled online individually during runtime via the Internet/Intranet. SIMATIC WinCC ControlDevelopment for SIMATIC WinCC Runtime Advanced and SIMATIC WinCC Runtime Professional • Expansion of the basic functionality with proprietary controls. • Development of proprietary VB.net or C# Controls for integration in WinCC Runtime Advanced and WinCC Runtime Professional SIMATIC Logon for SIMATIC Panels and SIMATIC WinCC Runtime Advanced and SIMATIC WinCC Runtime Professional • Creates user administration on a central computer to which one or more WinCC stations can be connected over Ethernet. • With each logging-on/off of a user on one of the connected stations, SIMATIC Logon checks whether a user password has been created and that the required privileges exist. • SIMATIC Logon supports the user in combination with the Audit option in meeting requirements in accordance with FDA 21 CFR Part 11 and EU178. SIMATIC WinCC Sm@rtServer for SIMATIC Panels and SIMATIC WinCC Runtime Advanced • Flexible solution for remote access to HMI systems • Remote maintenance of machines and plants via the Internet/ Intranet • Reduced downtimes for machines and plants due to direct remote access • Flexible solution for remote access to machines and plants Siemens ST 80 / ST PC · 2013 4/31 4 © Siemens AG 2013 HMI Software SIMATIC WinCC (TIA Portal) options WinCC Recipes ■ Overview ■ Benefits • Generation and management of machine parameters and production data on the basis of data records, and exchange with the automation device, e.g. with the machine. • Clear tabular representation of the data elements with the aid of a configurable screen object, or depiction in technological relationships across several process screens. • Simple operator guidance through standard functions. • Export/import of data records for further processing with other tools (e.g. MS Excel) ■ Function 4 • Option for SIMATIC WinCC Runtime Advanced and WinCC Runtime Professional for managing data records in recipes that contain related machine or production data • The data in a data set can be transferred, for example, from the control unit to the PLC to switch production to a different product variant • Licensing: - SIMATIC Panels / Multi Panels / Comfort Panels: No license is required. - WinCC Runtime Advanced: One license is required per operator station - WinCC Runtime Professional: A license is only required on the server (or single-user system). • Input of data records (e.g. operating parameters of a machine, production data for a plastics machine) on the HMI device as well as their storage and transfer to the control • Display or entry of data records via a configurable screen object or via several process screens distributed within the project • The data record elements are coupled with the process via a direct tag connection • Transmission of data records from or to the controller • Powerful interfaces enable a synchronized data exchange with the controller • Storage of data records on local data carriers or on remote data servers via networks • Logging of data records, e.g. as batch report/shift report • User-friendly and flexible management of data records by powerful standard functions The recipes and the associated data records are created using a separate, user-friendly WinCC Engineering editor and data is pre-assigned to them. A configurable table object is used for displaying the data at runtime. Furthermore, the individual data record elements can also be displayed directly based on standard input/output fields across several process screens. In this way, the data in technological views can be presented clearly to the operator. Import and export functions support the importing and exporting of data via external applications (e.g. MS Excel). 4/32 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 HMI Software SIMATIC WinCC (TIA Portal) options WinCC Recipes ■ Technical specifications ■ Ordering data Order No. WinCC Recipes for Runtime Advanced SIMATIC WinCC Recipes for Runtime Advanced 1) The values specified are maximum values Single license, license key only on USB stick Number of recipes 999 SIMATIC WinCC Recipes + Logging for Runtime Advanced 1) Number of elements per recipe 1) 2 000 Single license, license key only on USB stick User data length in KB per data record 256 SIMATIC WinCC Recipes for Runtime Professional 1) Number of data records per recipe 5 000 Single license, license key only on USB stick 1) When using arrays, each array element represents a recipe element WinCC Recipes for Runtime Professional The values specified are maximum values Number of recipes Unlimited 2) Number of elements per recipe 2) 500 3) User data length in KB per data record 3 000 3) Number of data records per recipe 5 000 2) 6AV2107-0JA00-0BB0 6AV2107-0HA00-0BB0 6AV2107-0JB00-0BB0 Online software delivery (OSD) 2) WinCC Recipes for Runtime Advanced 1) 6AV2107-0JA00-0BH0 Single license, license key download only; E-mail address required for the delivery WinCC Recipes for Runtime Professional 1) 6AV2107-0JB00-0BH0 Single license, license key download only; E-mail address required for the delivery 4 2) Limited by system resources. 1) 3) The sum of the number of recipe elements and number of data records must not exceed a value of 320,000. One license is required for each operator console. A license is not required for the engineering system for configuring the runtime option. 2) Current information and availability regarding the new delivery package can be found at: http://www.siemens.com/tia-online-software-delivery Siemens ST 80 / ST PC · 2013 4/33 © Siemens AG 2013 HMI Software SIMATIC WinCC (TIA Portal) options WinCC Logging ■ Overview ■ Benefits • Alarm and process value logs enable predictive diagnostics, which avoids downtimes • Early detection of danger and fault conditions • Increase of the product quality and the productivity thanks to regular analysis of the alarm and process value logs ■ Application • • • • • Transfer of the logs for evaluation and long-term archiving Detection of recurring error states Optimization of maintenance cycles Ensuring the quality standard Quality assurance and checking the utilization of production sequences • Documentation of process sequences 4 • Option for SIMATIC WinCC Runtime Advanced and WinCC Runtime Professional for logging process values and alarms • Logging of process values and alarms supports the acquisition and processing of process data from an industrial plant or machine. Evaluation of the logged process data provides information about the operating states of the plant or machine • Licensing: - SIMATIC Panels / Multi Panels / Comfort Panels: No license is required. - WinCC Runtime Advanced: One license is required per operator station - WinCC Runtime Professional: 500 Logging Tags are already included in the basic package The number of Logging Tags can be increased by means of additional licenses 4/34 Siemens ST 80 / ST PC · 2013 ■ Function • Time-controlled as well as manual or process-controlled swapping out of process data and alarms for long-term archiving • During runtime, swapped out data are read in and selectively analyzed using WinCC Runtime Professional - Presentation and evaluation of archived process data based on a configurable trend display. Reading of the values is facilitated by a read line. - Presentation and evaluation of archived alarms based on a configurable alarm view. - User-friendly navigation in the logs • External evaluation of the logs using MS standard tools • Various log types are supported: sequence and circular logs • Logging of process values and alarms on external, Windowssupported storage media - SIMATIC Panels and WinCC Runtime Advanced: CSV files, RDB files, Microsoft SQL Server via ODBC - WinCC Runtime Professional: Microsoft SQL Server 2005 • Powerful standard functions permit user-friendly and flexible utilization of the logs © Siemens AG 2013 HMI Software SIMATIC WinCC (TIA Portal) options WinCC Logging ■ Technical specifications ■ Ordering data Order No. WinCC Logging for Runtime Advanced SIMATIC WinCC Logging for Runtime Advanced 1) The values specified are maximum values Single license, license key only on USB stick Number of logs 100 Archivable data Process values, alarms SIMATIC WinCC Recipes + Logging for Runtime Advanced 1) Cyclical trigger for archiving process values (variables) 1s Max. number of entries per log (incl. sequence log) 500 000 1) SIMATIC WinCC Logging for Runtime Professional 1500 Logging Tags Log types Circular logs, sequence logs (max. 400 per log) Single license, license key only on USB stick Data storage format CSV (Comma Separated Variable), RDB (Runtime Data Base), Microsoft SQL database (database not included in scope of delivery) SIMATIC WinCC Logging for Runtime Professional 5000 Logging Tags 1) 6AV2107-0GA00-0BB0 Single license per option, license key only on USB stick 6AV2107-0GB00-0BB0 6AV2107-0GD00-0BB0 Single license, license key only on USB stick Dependent on memory medium used WinCC Logging for Runtime Professional The values specified are maximum values WinCC Logging for Runtime Professional Powerpack 1500 -> 5000 Logging Tags 6AV2107-2GD00-0BD0 Single license, license key only on USB stick Number of logs per single-user station/server 100 Archivable data Process values, alarms WinCC Logging Upgrade for SIMATIC WinCC Archives V7.0 (10 licenses) Measured values per second, max. Server/single-user station: 5 000 per sec. Single license per option, license key only on USB stick Log tags per single-user station/ server 80 000 2) Online software delivery (OSD) 2) Log types Circular log with and without long-term logging Data storage format Microsoft SQL 2005 database 2) 6AV2107-0HA00-0BB0 Dependent on the Logging Powerpack used for the log tags. 500 log tags are contained in the basis version. WinCC Logging for Runtime Advanced 1) 6AV2107-4GX00-0BF0 4 6AV2107-0GA00-0BH0 Single license, license key download only e-mail address required for the delivery WinCC Logging for Runtime Professional - 1500 Logging Tags 6AV2107-0GB00-0BH0 Single license, license key download only e-mail address required for the delivery WinCC Logging for Runtime Professional - 5000 Logging Tags 6AV2107-0GD00-0BH0 Single license, license key download only e-mail address required for the delivery WinCC Logging for Runtime Professional Powerpack 1500 -> 5000 Logging Tags 6AV2107-2GD00-0BJ0 Single license, license key download only e-mail address required for the delivery 1) One license is required for each operator console. A license is not required for the engineering system for configuring the runtime option. 2) Current information and availability regarding the new delivery package can be found at: http://www.siemens.com/tia-online-software-delivery Siemens ST 80 / ST PC · 2013 4/35 © Siemens AG 2013 HMI Software SIMATIC WinCC (TIA Portal) options WinCC Audit ■ Overview ■ Technical specifications WinCC Audit Storage location for Audit Trail when used on the Panel Plug-in Flash memory card or via Ethernet in the higher-level PC Storage location for Audit Trail when using WinCC Runtime Advanced Local hard disk or via Ethernet in the higher-level PC Execution platform SIMATIC Panels Mobile Panel 277, TP/OP 277 SIMATIC Multi Panels MP 277, MP 377 SIMATIC Comfort Panels all PC systems SIMATIC WinCC Runtime Advanced ■ Ordering data 4 • Option for SIMATIC WinCC Runtime Advanced as well as SIMATIC Panels for recording operations in an audit trail, and electronic signature • The audit trail is furnished with a security mechanism that displays subsequent manipulations. • A user-friendly configuration function, which is included as standard in WinCC, is used to define the following: - Which user actions should be recorded in the audit trail during runtime - Which important operator actions during execution time require electronic signature/comments • Available for the following SIMATIC HMI systems: - Comfort Panels - Mobile Panels - TP/OP 277 - MP 277 - MP 377 - WinCC Runtime Advanced • Licensing: - A license is required for every operator control unit (panel or PC). ■ Benefits • Audit supports the user in meeting special quality requirements, e.g. - Production plant requiring validation according to 21 CFR Part 11 FDA 1) - In respect of traceability according to EU 175/2002 2) • The entries in the audit trail are uniquely assigned to users. This means that responsibilities are clearly identifiable. • The audit trail, stored as a CSV file 3), can be checked via a security mechanism to find out if subsequent changes have been made. • For particularly important user actions, e.g., starting production or loading new recipes, electronic signatures and comments can be configured and then called up and logged during runtime. 1) The FDA (Food and Drug Administration) is the American public health body 2) 21 CFR Part 11- law on plant validation 3) CSV Comma Separated Values 4/36 Siemens ST 80 / ST PC · 2013 SIMATIC WinCC Audit for SIMATIC Panels Order No. 6AV2107-0RP00-0BB0 Single license, license key only on USB stick SIMATIC WinCC Audit for Runtime Advanced 6AV2107-0RA00-0BB0 Single license, license key only on USB stick Online software delivery (OSD) 1) WinCC Audit for SIMATIC Panels 6AV2107-0RP00-0BH0 Single license, license key download only E-mail address required for the delivery WinCC Audit for Runtime Advanced 6AV2107-0RA00-0BH0 Single license, license key download only E-mail address required for the delivery 1) Current information and availability regarding the new delivery package can be found at: http://www.siemens.com/tia-online-software-delivery © Siemens AG 2013 HMI Software SIMATIC WinCC (TIA Portal) options SIMATIC Logon ■ Overview ■ Design SIMATIC Logon for Panels and WinCC Runtime Advanced SIMATIC Logon and SIMATIC Logon Remote Access are installed on a central station. • Option for connecting SIMATIC Panels and PCs with SIMATIC WinCC Runtime Advanced as well as WinCC Runtime Professional to a central user administration. • Creates user administration on a central computer to which one or more panels or WinCC stations can be connected over Ethernet. • With each logging-on/off of a user on one of the connected stations, SIMATIC Logon checks whether a user password has been created and that the required privileges exist. SIMATIC Logon for Panels and WinCC Runtime Advanced • All users of the SIMATIC Panels or WinCC Runtime Advanced stations can be managed plant-wide from a central location • Supports the user in combination with the Audit option in meeting requirements in accordance with FDA 21 CFR Part 11 and EU178. • Licensing: SIMATIC Logon (basic license) and SIMATIC Logon Remote Access (3-pack license) for the connection of 3 panels or WinCC Runtime Advanced stations to a central user administration. Additional stations can be connected by using further SIMATIC Logon Remote Access licenses (3-pack/10-pack). SIMATIC Logon for WinCC Runtime Professional • All users of WinCC Runtime Professional can be managed plant-wide from a central location. • The central user management with SL utilizes Windows mechanisms and must be installed on all participating WinCC Runtime Professional stations. • Licensing: SIMATIC Logon (basic license) is included in the basic package of WinCC Runtime Professional ■ Benefits • Centralized configuration of all access authorizations of a distributed system avoids unnecessary travel times. Timeconsuming multiple configurations for each individual local station become unnecessary. Accordingly, users can be easily configured from a central location. • All access data apply throughout the plant on every connected station. Additional access data on local subsystems is no longer necessary. The following Runtime stations are connected to the central station via the Ethernet network: • PCs with WinCC Runtime Advanced • SIMATIC Panels from the 177 series or higher (with Ethernet interface) • SIMATIC Mobile Panels from the 177 series or higher (with Ethernet interface) • SIMATIC Multi Panels • SIMATIC Comfort Panels SIMATIC Logon for WinCC Runtime Professional The SIMATIC Logon can be used for the central user management of several WinCC Runtime Professional stations. Operation in a Windows Workgroup or even in a domain is possible. ■ Function Users receive a unique user ID, user name and password. This information is encrypted and stored at a central point (for SIMATIC Logon in the Windows user management). Functions such as changing the password, automatic log-off after a predefined time and lockout after several incorrect entries of a password ensure maximum security of operation. In addition, SIMATIC Logon allows setting up new users online, plant-wide and across applications, or blocking of existing users. SIMATIC Logon also supports electronic signature. ■ Ordering data Order No. SIMATIC Logon V1.5 6ES7658-7BX51-0YA0 Basic license 1) For panels or WinCC Runtime Advanced stations, the corresponding number of additional SIMATIC Logon Remote Access licenses is required. No SIMATIC Logon Remote Access licenses are required for WinCC Runtime Professional SIMATIC Logon Upgrade to V1.5 6ES7658-7BX51-0YE0 SIMATIC Logon Remote Access (3 clients) 6ES7658-7BA00-2YB0 Remote Access for 3 clients; Single License for 3 SIMATIC Logon Remote Access clients; the number of licensed clients is determined from the sum of the installed SIMATIC Logon Remote Access licenses. SIMATIC Logon Remote Access (10 clients) 6ES7658-7BB00-2YB0 Remote Access for 10 clients; Single License for 10 SIMATIC Logon Remote Access clients; the number of licensed clients is determined from the sum of the installed SIMATIC Logon Remote Access licenses. 1) SIMATIC Logon V1.5 included in scope of supply of WinCC Runtime Professional. Siemens ST 80 / ST PC · 2013 4/37 4 © Siemens AG 2013 HMI Software SIMATIC WinCC (TIA Portal) options WinCC Sm@rtServer ■ Overview Sm@rtServer Master Station Sm@rtClient Operator Station 1 Operator Station 2 Operator Station n G_ST80_XX_00071 ... Industrial Ethernet 4 • Option for SIMATIC WinCC Runtime Advanced plus SIMATIC Panels for communication between various SIMATIC HMI systems. • Available for the following SIMATIC HMI systems: - Comfort Panels - Mobile Panel 177 PN, Mobile Panel 277 - TP 177B PN/DP, OP 177B PN/DP - TP 277, OP 277 - MP 177, MP 277, MP 377 - WinCC Runtime Advanced • A SIMATIC HMI system can be used to control or monitor another system remotely; entry level for client/server configurations for distributed operator stations or for solutions with head end or control room • Local operation, visualization and data processing are as possible as plant-wide access to information. Integrated information flows ensure an overview of the status of all processes. • Licensing: The "SIMATIC WinCC Sm@rtServer for Panel" or "SIMATIC WinCC Sm@rtServer for WinCC Runtime Advanced" license must be installed on the server HMI device. A license is not required for the engineering system for configuring the runtime option. Note: When accessing the operator stations via the Sm@rtServer option, suitable protective measures (including IT security such as network segmentation) should be taken in order to ensure safe operation of the system. You will find more information on the topic of Industrial Security on the Internet at: http://www.siemens.com/industrialsecurity ■ Benefits • Flexible solution for remote access to HMI systems • Quick elimination of malfunctions or downtimes – thus increasing the productivity – through global access to machines/plants by the service and maintenance personnel. 4/38 Siemens ST 80 / ST PC · 2013 • Avoidance of on-site service calls. © Siemens AG 2013 HMI Software SIMATIC WinCC (TIA Portal) options WinCC Sm@rtServer ■ Application • Operator control and monitoring of machines covering large areas with several operator stations by one operator. • Operator control and monitoring of machine-level HMI systems from one central station (e.g. head-end station of a production line or from a control room) Sm@rtServer Master Station • Remote maintenance and servicing of machines/plants over the Internet/Intranet Sm@rtClient Operator Station 1 Operator Station 2 Operator Station n G_ST80_XX_00071 ... Industrial Ethernet Application of the Sm@rtClient concept: Coordinated operation of several operator stations Master Control Station Sm@rtClient display Industrial Ethernet Server 1 Sm@rtServer Server 2 Sm@rtServer Server 3 Server 4 Sm@rtServer Sm@rtServer G_ST80_XX_00072 PROFIBUS Use of the Sm@rtClient display: Operator control and monitoring of machine-level HMI systems from one central station Siemens ST 80 / ST PC · 2013 4/39 4 © Siemens AG 2013 HMI Software SIMATIC WinCC (TIA Portal) options WinCC Sm@rtServer ■ Function ■ Application (continued) Coordinated operation of several operator stations: • The HMI application and communication with the controller takes place via the master station. "Sm@rtClients" can be activated from here in the case of machines/plants with larger dimensions which require a larger number of HMI devices. The Sm@rtClients are then provided with access to the master station and thus to the process. Access procedures guarantee that only one operator system can actively access the process at any given time. • Embedded in process screens, a configurable screen object (Sm@rtClient display) represents the screen of the relevant HMI system (Sm@rtServer) • Powerful standard functions permit user-friendly and flexible operation of the display {jwVpw pzkuVkzs tVy lGz wjVwn p pzkuVkzs tVy Remote operator control and monitoring of SIMATIC HMI systems using Industrial Ethernet and/or via the Intranet/Internet jGYaG vGGG GGpVpG GGGGb GGG Engineering Station PC/PG jGXaG vGGG GGtGpG l pGl wyvmpi|z nz{_WWWW^] 4 G_ST80_XX_00073 pG Remote operator control and monitoring of SIMATIC HMI systems using Industrial Ethernet and/or via the Intranet/Internet 4/40 Siemens ST 80 / ST PC · 2013 Remote control of an operating station: • The HMI application and communication with the controller takes place via the HMI system. Using the Sm@rtServer, the HMI systems in the machines/systems can be serviced remotely. An access process ensures that only one operator (either locally at the machine or remotely via Internet Explorer) can actively access the process at one time. • Microsoft Internet Explorer V6.0 SP1 or higher is sufficient for accessing an HMI system. © Siemens AG 2013 HMI Software SIMATIC WinCC (TIA Portal) options WinCC Sm@rtServer ■ Technical specifications ■ Ordering data WinCC Sm@rtServer The values specified are maximum values Execution platform SIMATIC Comfort Panels all SIMATIC Panels Mobile Panel 177 PN, Mobile Panel 277, TP/OP 177B PN/DP, TP/OP 277 SIMATIC Multi Panels MP 177, MP 277, MP 377 PC systems SIMATIC WinCC Runtime Advanced Number of Sm@rtClients that can simultaneously connect to a Sm@rtServer Comfort Panel as Sm@rtServer 2 clients for 4" devices 3 clients for 7", 9", 12" and 15" devices 2 clients for 19" devices 1 client for 22" devices Mobile Panel 177 PN, TP/OP 177B PN/DP, MP 177 as Sm@rtServer 2 clients Mobile Panel 277, TP/OP 277, MP 277 as Sm@rtServer 3 clients for 6" devices 2 clients for 8" and 10" devices MP 377 as Sm@rtServer 3 clients for 12" devices 2 clients for 15" devices 1 client for 19" devices WinCC Runtime Advanced as Sm@rtServer 5 clients Order No. WinCC Sm@rtServer for SIMATIC Panels 1) Single license, license key only on USB stick 6AV2107-0CP00-0BB0 WinCC Sm@rtServer for Runtime Advanced 1) Single license, license key only on USB stick 6AV2107-0CA00-0BB0 Online software delivery (OSD) 2) WinCC Sm@rtServer for SIMATIC Panels 1) Single license, license key download only E-mail address required for the delivery 6AV2107-0CP00-0BH0 WinCC Sm@rtServer for Runtime Advanced 1) Single license, license key download only E-mail address required for the delivery 6AV2107-0CA00-0BH0 4 1) The license must be installed on the Sm@rtServer HMI device. A license is not required for the engineering system for configuring the runtime option. 2) Current information and availability regarding the new delivery package can be found at: http://www.siemens.com/tia-online-software-delivery Siemens ST 80 / ST PC · 2013 4/41 © Siemens AG 2013 HMI Software SIMATIC WinCC (TIA Portal) options WinCC Server / WinCC Client ■ Overview WinCC Client WinCC Client WinCC Client TCP/IP SIMATIC S7-1200 SIMATIC S7-300 SIMATIC S7-400 4 • Option for SIMATIC WinCC Runtime Professional, which permits the configuration of a powerful client/server system • One of the following operating systems must be available to install the option on the server: Windows Server 2003, Windows Server 2003 R2, Windows Server 2008 or Windows XP Professional. When using Windows XP Professional, max. 3 clients can be connected. • A number of coordinated HMI stations can be operated in a single group with networked automation systems 4/42 Siemens ST 80 / ST PC · 2013 nz{_WWW[^Y Process bus • Client/server solution: One server can supply up to 32 connected clients with process and archive data, alarms, screens and reports - Requirement: Network connection (TCP/IP) between the server PC and the connected clients • Licensing: - A WinCC Runtime Professional license on the server with the appropriate number of PowerTags and the "WinCC Server for RT Professional" license. - The "WinCC Client for RT Professional" license on the clients. © Siemens AG 2013 HMI Software SIMATIC WinCC (TIA Portal) options WinCC Server / WinCC Client ■ Benefits • Integrated scalability from the single-user system to the client/ server solution • Considerably expanded quantity structure, relieves the load on the individual servers, and thus better performance through the distribution of the overall application or of the tasks among several servers ■ Application In a complex plant, WinCC Runtime Professional can be configured as a distributed system depending on the requirements: • Functional distribution (e.g. alarm server, log server, etc.), or • Distribution corresponding to the physical plant structure (e.g. body-in-white, paint shop, etc.). ■ Function All process data of a WinCC project is stored in different Runtime databases, e.g. alarms, trend values, etc. These Runtime databases are located on a central computer, the WinCC Server, instead on each HMI device. The operator stations, i.e. the WinCC Clients, then access the WinCC Server. WinCC Clients and WinCC Server are independent systems. You can also connect WinCC Clients subsequently. Alternatively, you can activate and deactivate a project from a WinCC Client. ■ Ordering data Order No. SIMATIC WinCC server for Runtime Professional Single license, license key only on USB stick 6AV2107-0EB00-0BB0 SIMATIC WinCC Client for Runtime Professional V12 Single license, license key on USB stick, software and documentation on DVD 6AV2107-0DB02-0AA0 SIMATIC WinCC Client for Runtime Professional ASIA V12 Single license, license key on USB stick, software and documentation on DVD 6AV2107-0DB12-0AA0 Online software delivery (OSD) 1) SIMATIC WinCC server for Runtime Professional Single license, license key download only, e-mail address required for the delivery 6AV2107-0EB00-0BH0 SIMATIC WinCC Client for Runtime Professional V12 Single license, software an d license key download. E-mail address required for the delivery 6AV2107-4DB02-0AK0 4 A license is not required for the engineering system for configuring the runtime option. 1) Current information and availability regarding the new delivery package can be found at: http://www.siemens.com/tia-online-software-delivery Siemens ST 80 / ST PC · 2013 4/43 © Siemens AG 2013 HMI Software SIMATIC WinCC (TIA Portal) options WinCC WebNavigator ■ Overview ~jj zjhkhG ~jj ~G ~jj kt shu ~jjG RG~uV kt wyvmpul{ wyvmpi|z nz{_WWW\\] 4 • Option for SIMATIC WinCC Runtime Professional for operating and monitoring plants over the Internet, company Intranet or LAN. • Configuration from: - A web server with SIMATIC WinCC Runtime Professional as single-user or server version and a web client that permits operator control and monitoring of a current WinCC Runtime Professional project using the Internet Explorer. • Licensing: - A license is required for using the Web server. - Server-based licenses are available for access to the web server by 3, 10, 25 or 50 clients. - Client-based licenses are available for guaranteed access to the web server (Diagnostics Client) 4/44 Siemens ST 80 / ST PC · 2013 Note: When accessing the operator stations via the WinCC WebNavigator option, suitable protective measures (including IT security such as network segmentation) should be taken in order to ensure safe operation of the system. You will find more information on the topic of Industrial Security on the Internet at: http://www.siemens.com/industrialsecurity © Siemens AG 2013 HMI Software SIMATIC WinCC (TIA Portal) options WinCC WebNavigator ■ Benefits • Operator control and monitoring across long distances and on different platforms (PC, local panel, mobile PDA) • Large configurations with up to 50 operator stations • Fast update rates due to event-driven communication • Optimally tailored clients for operating and monitoring, analysis, service and diagnostics • Acceptance of configuration data for the web, generally without changes • Minimum maintenance costs due to central software administration • High security standards and availability - Support for commonly used security mechanisms (routers, firewalls, proxy servers) - WinCC access authorizations and user administration • Support of Microsoft Internet Explorer, including "tabbed browsing". A new license is not required for separate tabs. • With the WinCC Web Viewer (WinCC Viewer RT), the process screens can be displayed on the web client independently of the Internet Explorer. Settings for the client are made on the client itself. The WinCC Web Viewer can also be used in conjunction with the MS Terminal Service. • The SIMATIC WinCC WebNavigator can also be operated in "view only" mode and is thus used as tool for monitoring and navigating using Internet Explorer or WinCC Web Viewer (WinCC Viewer RT). • Web server logins and logouts are recorded in the alarm and audit log. • There is a gadget available for the Windows 7 operating system in which selected WinCC process screens can be displayed. No additional WebNavigator license is required for the gadget. The WebNavigator server can be selected directly via the gadget. • Security is increased by adjustable automatic logout. If an automatic logout is to take place, an absolute or inactive time period can be set. Highlights: • Multiple Web servers can be accessed from a single Web client • User-friendly services and tools for distributing customized objects (controls, files) to web clients can be supplied for use as an integration platform. These components can then also be integrated into cross-web/server navigation. • Both Internet Explorer and the supplied, browser-independent WinCC Web Viewer (WinCC Viewer RT) can be used as a front end • Access to WebNavigator Server of the WinCC V7.x series. ■ Application In addition to the typical use of the WebNavigator in WANs (Wide Area Networks), the WebNavigator can also be used to implement especially low-cost applications. This especially includes applications that have a pronounced distributed structure (water/wastewater, oil and gas), or in which access to process information is only sporadic (building management). The WebNavigator also permits vertical integration, i.e. a networked IT landscape with integrated data flow between the planning and operating level of a company. Only a standard browser is required for direct access to current process information. In addition to the standard WebNavigator licensing, there is the "Diagnostics Client" with identical functionality but different licensing. It is especially suitable for the following applications: • Remote diagnostics/operation of several unmanned WinCC Runtime Professional stations • Central control rooms that monitor several web servers via one user interface • Maintenance personnel who require guaranteed access to the server at any time, regardless of the number of users already logged on to the server. On the server side, only one WebNavigator Diagnostics Server license or, alternatively, one Standard WebNavigator license is required. 4 ■ Design Licenses for the WebNavigator The WebNavigator Client software can be installed as many times as required without the need for a license. • Server-based licensing - A license is required for using the WebNavigator Server. - Licenses are available for simultaneous access to the Web server by 3, 10, 25 or 50 clients. • Diagnostics client licensing - For cost-optimized access by one or a small number of WebNavigator clients to numerous Web servers (e.g. for diagnostic purposes). This client license provides guaranteed access to Web servers at any time. In respect of function there is no difference compared with regular WebNavigator clients and the two can be mixed. WebNavigator Clients are capable of accessing several different Web Servers. Thin client solutions The WebNavigator can also run under Windows Server 2003 or Windows Server 2008 terminal services. A Windows Server 2003 or Windows Server 2008 (or higher) operating system is required. This makes it possible to connect SIMATIC Thin Clients as visualization stations to WinCC Runtime Professional, for example. For this purpose, the Windows terminal services must be installed on the PC on which the Web Client is installed. A Windows Server 2003 or Windows Server 2008 (or higher) operating system is required. Up to 25 thin clients can be connected to one terminal server. Applications: • Mobile devices • Handhelds • Rugged on-site visualizations Siemens ST 80 / ST PC · 2013 4/45 © Siemens AG 2013 HMI Software SIMATIC WinCC (TIA Portal) options WinCC WebNavigator ■ Design (continued) Hybrid configuration System requirements: WinCC WebNavigator – Server V12 • Windows 7 SP1 (32- and 64-bit) Business, Enterprise and Ultimate (max. 3 Clients) • Windows XP Professional Service Pack 3 (max. 3 clients) • Windows Server 2003 SP2 • Windows Server 2008 SP2 32-bit • Windows Server 2008 R2 SP1 64-bit • Internet Explorer V7.0, V8.0, V9.0 • Microsoft SQL Server 2008 R2 SP1 32-bit (included in the WinCC product delivery) • WinCC Basic System V12 System requirements: WinCC WebNavigator – Client V12 • Internet Explorer 7, IE 8, IE9 4 System requirements: WinCC WebNavigator – Server V11 • Windows 7 (32-bit) Business, Enterprise and Ultimate (max. 3 clients) • Windows XP Professional Service Pack 2 (max. 3 clients) • Windows Server 2003 SP2 and Windows Server R2 SP2 • Windows Server 2008 • Internet Explorer 7 as well as Internet Explorer 8 • Microsoft SQL Server 2005 SP2 (scope of supply of WinCC) • WinCC Runtime Professional V11 System requirements: WinCC WebNavigator – Client V11 • Internet Explorer 7 as well as Internet Explorer 8 ■ Function WinCC Professional makes setting up and configuring a WebNavigator server very easy. WinCC process screens to be visualized via the Internet are created as usual in WinCC Professional and the web access is activated via a process screen option. To display WinCC process screens on the web client, the Microsoft Internet Explorer or browser is used independent of the supplied WinCC Web Viewer (WinCC Viewer RT). The operator on the Web Client is integrated in the central WinCC user administration and can operate and monitor the system according to the configured access rights. The WebNavigator supports all standard security mechanisms that can be used for applications on the Internet, e.g. routers, firewalls and proxy servers. ■ Ordering data Order No. SIMATIC WinCC WebNavigator for Runtime Professional Single license, license key only on USB stick • 3 clients, runtime software • 10 clients • 25 clients • 50 clients • 100 clients • 150 clients 6AV2107-0KD00-0BB0 6AV2107-0KF00-0BB0 6AV2107-0KH00-0BB0 6AV2107-0KK00-0BB0 6AV2107-0KM00-0BB0 6AV2107-0KP00-0BB0 SIMATIC WinCC WebNavigator for Runtime Professional Powerpacks Single license, license key only on USB stick • From 3 to 10 clients • From 10 to 25 clients • From 25 to 50 clients • From 50 to 100 clients • From 100 to 150 clients 6AV2107-2KF00-0BD0 6AV2107-2KH00-0BD0 6AV2107-2KK00-0BD0 6AV2107-2KM00-0BD0 6AV2107-2KP00-0BD0 SIMATIC WinCC WebNavigator Diagnostics Server/Client Single license, license key only on USB stick • WinCC WebDiagnostics Server for Runtime Professional, Runtime software • WinCC WebDiagnostics Client for Runtime Professional, Runtime software 6AV2107-0KR00-0BB0 6AV2107-0KT00-0BB0 New type of delivery Online software delivery (OSD) 1) WinCC WebNavigator for Runtime Professional Single license, license key download only, e-mail address required for the delivery • 3 clients • 10 clients • 25 clients • 50 clients • 100 clients • 150 clients 6AV2107-0KD00-0BH0 6AV2107-0KF00-0BH0 6AV2107-0KH00-0BH0 6AV2107-0KK00-0BH0 6AV2107-0KM00-0BH0 6AV2107-0KP00-0BH0 WinCC WebNavigator for Runtime Professional Powerpacks Single license, license key download only, e-mail address required for the delivery • 3 to 10 clients • 10 to 25 clients • 25 to 50 clients • 50 to 100 clients • 100 to 150 clients 6AV2107-2KF00-0BJ0 6AV2107-2KH00-0BJ0 6AV2107-2KK00-0BJ0 6AV2107-2KM00-0BJ0 6AV2107-2KP00-0BJ0 WinCC WebNavigator Diagnostics Server/Client Single license, license key download only, e-mail address required for the delivery • WinCC Web Diagnostics Server for Runtime Professional • WinCC Web Diagnostics Client for Runtime Professional 6AV2107-0KR00-0BH0 6AV2107-0KT00-0BH0 A license is not required for the engineering system for configuring the runtime option. 1) 4/46 Siemens ST 80 / ST PC · 2013 Current information and availability regarding the new delivery package can be found at: http://www.siemens.com/tia-online-software-delivery © Siemens AG 2013 HMI Software SIMATIC WinCC (TIA Portal) options WinCC DataMonitor ■ Overview ~jj zjhkhG ~jj ~G ~jj kt shu ~jjG RG~uV kt wyvmpul{ nz{_WWW\\] wyvmpi|z • The WinCC DataMonitor is used for displaying and evaluating current process states and historical data on office PCs using standard tools such as Microsoft Internet Explorer or Microsoft Excel. In doing so, the DataMonitor client is supplied by a Web server with current and historic process data and alarms. All staff ranging from machine operators to corporate managers can use the DataMonitor to obtain information. • DataMonitor is a suite of Internet-capable tools: - Process Builder Tool exclusively for monitoring and navigating via WinCC Runtime Professional screens using Internet Explorer (view only) or the WinCC Web Viewer (WinCCViewerRT) - Excel Workbooks Logging tool that integrates WinCC Runtime Professional Archive and online values into Microsoft Excel and supports online analysis - Published Reports Event or time-driven implementation of Excel or PDF reports for the output of process data and analysis results - Webcenter Individual configuration of Internet pages and summary of information within a portal with reference to WinCC Runtime Professional applications - Trends and Alarms (tables and graphs) are preconfigured Webcenter pages • DataMonitor does not require manual client installation because it loads the required components from the web server. • There is no installation required on the client for the Webcenter and Trends and Alarms functions. • Licensing: - Licenses for access by 1, 3, 10, 25, or 50 DataMonitor clients are available. - Any combination of DataMonitor and WebNavigator licenses can be used in an application. Note: When accessing the operator stations via the WinCC DataMonitor option, suitable protective measures (including IT security such as network segmentation) should be taken in order to ensure safe operation of the system. You will find more information on the topic of Industrial Security on the Internet at: http://www.siemens.com/industrialsecurity Siemens ST 80 / ST PC · 2013 4/47 4 © Siemens AG 2013 HMI Software SIMATIC WinCC (TIA Portal) options WinCC DataMonitor ■ Benefits ■ Function • Information can be compiled online individually during runtime via the Internet/Intranet. • Efficiently monitor and analyze production lines. - Display and evaluation of current process states and historical data on remote office PCs with standard tools such as Microsoft Internet Explorer or Excel. - Easy access to production data via the Intranet or Internet - Quick ascertainment of the production situation • Easily collect and distribute information. - Automated report creation - No additional configuration effort through direct use of screens from the WinCC project - No training required for standard products - Easy exchange of configuration data • Substantiate decisions with reports. - Evaluation via ready-made templates for special analyses of the business processes (e.g. reports, statistics) - Display bottlenecks transparently - Individual views for user and situation - Relative and absolute timeframe for information generation • View production status anywhere and anytime. - Individual views of information in production - View the process and system operation - Historical data can be compiled online individually 4 Highlights: • With the Webcenter function, WinCC Runtime Professional archive tags can be accessed without changing the configuration system. • Dedicated Internet pages can be created for displaying data with the Webcenter. For this purpose, the following tools, which can be integrated in the Internet sites, are available. - Bar chart, pie chart, trend curve display - Process value table and statistics functions for the process values - Alarms, hit list for alarms - Message text display for individual message texts, message display, selection list of created reports, - Links to internal and external pages - Display of graphics in jpg format - Representation of the WinCC Runtime Professional process screens • The analyses can be made with relative or absolute time specification. This enables comparisons of identical time periods on different days. • Reports generated with Excel or with WinCC Professional can be made available on the DataMonitor server or e-mailed automatically to the relevant group of people based on time intervals or triggered by events. • Connections to WinCC Runtime Professional and to swapped out archives can be established • Support of Microsoft Internet Explorer version, including "tabbed browsing". 4/48 Siemens ST 80 / ST PC · 2013 • All tools are fully Internet-compatible and, therefore, support access via any type of connection (LAN, GSM, radio, modem, Internet, etc.). • All popular security mechanisms such as login/password, firewalls, encryption, etc. are supported. • Users can combine the available tools at will. Licensing only takes into account simultaneous access to one Web server. • For display purposes, screens from the WinCC project can be used or special overview displays configured. Animations, scripts, navigation and access rights remain valid. • The WinCC DataMonitor supports a display function only. • Company-wide Excel reports, which contain historical and current process values, can be stored centrally for general access (reports, statistics). However, local queries to meet individual requirements can be compiled and executed online. Plot and tabular representation are supported for archive data already swapped out. • Data can be automatically entered into created report templates and distributed by e-mail. • Pre-made elements make the assembly of individual web pages easier for evaluating information. • Individual information compilation on one or more Internet pages with the option of branching to other detail pages. • Pre-made Internet pages for trend and alarm display enable an ad-hoc entry to Internet data evaluation. • An higher-level navigation feature provides a common framework for the various tools. • Enhanced user management for the web center in order to assign individual Internet pages and created reports to specific user groups. • A search function facilitates the management of connections to the WinCC server. • Swapped out archives can be connected and evaluated in the DataMonitor WebCenter. • Excel reports created offline can be loaded onto the DataMonitor server and are thus made available to selected user groups or for automatic distribution. © Siemens AG 2013 HMI Software SIMATIC WinCC (TIA Portal) options WinCC DataMonitor ■ Ordering data SIMATIC WinCC DataMonitor for Runtime Professional Single license, license key only on USB stick • 1 client • 3 clients • 10 clients • 25 clients • 50 clients SIMATIC WinCC DataMonitor for Runtime Professional Powerpacks Single license, license key only on USB stick • From 1 to 3 Clients • From 3 to 10 Clients • From 10 to 25 Clients • From 25 to 50 Clients Order No. Order No. Online Software Delivery (OSD) 1) 6AV2107-0LB00-0BB0 6AV2107-0LD00-0BB0 6AV2107-0LF00-0BB0 6AV2107-0LH00-0BB0 6AV2107-0LK00-0BB0 6AV2107-2LD00-0BD0 6AV2107-2LF00-0BD0 6AV2107-2LH00-0BD0 6AV2107-2LK00-0BD0 SIMATIC WinCC DataMonitor for Runtime Professional Single license, license key download only, e-mail address required for the delivery • 1 client • 3 clients • 10 clients • 25 clients • 50 clients 6AV2107-0LB00-0BH0 6AV2107-0LD00-0BH0 6AV2107-0LF00-0BH0 6AV2107-0LH00-0BH0 6AV2107-0LK00-0BH0 SIMATIC WinCC DataMonitor for Runtime Professional Powerpacks Single license, license key download only, e-mail address required for the delivery • From 1 to 3 clients • From 3 to 10 clients • From 10 to 25 clients • From 25 to 50 clients 6AV2107-2LD00-0BJ0 6AV2107-2LF00-0BJ0 6AV2107-2LH00-0BJ0 6AV2107-2LK00-0BJ0 A license is not required for the engineering system for configuring the runtime option. 1) Current information and availability regarding the new delivery package can be found at: http://www.siemens.com/tia-online-software-delivery Siemens ST 80 / ST PC · 2013 4/49 4 © Siemens AG 2013 HMI Software SIMATIC WinCC (TIA Portal) options WinCC ControlDevelopment ■ Overview ■ Ordering data You use the ControlDevelopment option to create your own .net controls for controlling and monitoring processes. You can use the controls in screens for WinCC Runtime Advanced and WinCC Runtime Professional. You create the controls based on the standard controls from Visual Studio 2005/2008 Professional .net. Application examples: • Special trend views • Own recipe managements • Complex display objects ■ Benefits The ControlDevelopment option enables user-specific software solutions based on a proven building block principle: • Lower development overhead by using standards (Visual Studio 2005/2008 Professional .net) • Very short "Time-to-Market" resulting in a competitive advantage • Utilization of tried components and proven industrial functionality 4 The development of proprietary controls for WinCC Runtime Advanced and WinCC Runtime Professional does not require expensive, special hardware. 4/50 Siemens ST 80 / ST PC · 2013 WinCC ControlDevelopment V12 • Runtime license, single license, software and documentation on CD • Runtime software, single license, software download (e-mail address required for the delivery) 1) 1) Order No. 6AV2107-0TA02-0DA8 6AV2107-0TA02-0DG8 Current information and availability regarding the new delivery package can be found at: http://www.siemens.com/tia-online-software-delivery ■ More information Further information can be found in the Internet at: http://www.siemens.com/tia-portal © Siemens AG 2013 HMI Software Software for energy management Software for energy management ■ Overview SIMATIC offers numerous reasons for corporate energy management in industrial plants. However, there is one in particular: It makes an important contribution towards improving plant productivity. This results in enhanced competitiveness. Energy management with SIMATIC makes energy flows transparent in production plants. This supports the analysis and derivation of energy saving potential. The result: Permanently increased efficiency, higher productivity and an improved cost situation. 4 Siemens ST 80 / ST PC · 2013 4/51 © Siemens AG 2013 HMI Software Software for energy management SIMATIC B.Data ■ Overview SIMATIC B.Data V5.3 SP2 Energy Management System SIMATIC B.Data is a modular, cross-sector energy management system for industrial firms. Energy management – Company portal 4 WinCC Automation field level Energy planning and procurement Energy controlling Energy purchase Purchase support Scenario calculator Emission CO2 emission monitoring Wastewater disposal Forecast Energy forecast Budget planning Energy accounting Cost center allocation Evaluation/invoicing Monitoring and reporting Connection of external systems Facility management ERP (e.g. SAP R/3) Maintenance management Energy reporting system Analysis and reporting Workflow system Intranet/Internet viewer Energy schedule Energy purchase schedule Specifications for Load management Energy and material balance KPI calculation Production allocation Fault/alarm management Alarms/messages Remote alarms (text message) Operation and control system Central detection Plant visualization Data processing and archiving Interfaces to lower-level systems Meters/ measuring devices Process control/ building management systems PLCs Load management Load shedding Load control Circuitbreakers Mobile data acquisition G_ST80_XX_00379 B.Data ■ Benefits The option SIMATIC B.Data forms the basis of a cost-effective energy management system for reducing energy costs and increasing energy efficiency, and it confers the following immediate benefits: • It creates company-wide transparency, thanks to continuous energy balancing and materials balancing for the power generation systems and loads • It allows energy costs to be allocated according to the costsby-cause principle and permits transfer to the billing system (e.g. SAP R/3 CO) • It generates characteristic values for well-informed suggestions for increasing the efficiency of power generation systems and loads 4/52 Siemens ST 80 / ST PC · 2013 • It provides planning reliability thanks to production-related load and demand forecasts • It supports purchasing with cost-optimized energy procurement • It fulfills the legal obligations for monitoring and reporting on greenhouse gas emissions (CO2 emissions) • It relieves personnel of extra work through automatically updating internal and external energy reports • It supports customers in the continuous improvement of energy efficiency (e.g. ISO 50001) by integrated project management for energy efficiency measures © Siemens AG 2013 HMI Software Software for energy management SIMATIC B.Data ■ Design SIMATIC B.Data V5.3 SP2 Basic System The B.Data Basic System is available in variants for 100, 500, 1 000 and 30 000 tags and comprises the following components: • A B.Data acquisition component (WinCC, OPC, etc.) • A B.Data Client • B.Data Mobile • ERP interface • Reporting, Trender, Visu, document management, Matrix, KPI, Profile SIMATIC B.Data Software Update Service (SUS) For each B.Data Basic System there is a corresponding SUS (Software Update Service), which is dependent on the number of tags. The SUS is valid for 1 year. The contract is automatically extended by 1 more year unless canceled 3 months prior to expiration. SIMATIC B.Data V5 Expansions The scope of B.Data can be extended by purchasing add-on packages: • B.Data Web Server • B.Data Client • B.Data Energy Forecasting and Planning • B.Data Acquisition Component ■ Function Acquisition and pre-processing of energy and operating data from WinCC • In addition to an interface to WinCC, SIMATIC B.Data also offers the latest interface standards such as OPC, ODBC, ASCII, or XML • Preprocessing of energy data in a real-time calculation core that can be freely modeled including a formula editor for defining and configuring new calculation functions (heat calculations for boilers, quality for cogeneration plants, etc.) • B.Data Mobile for mobile recording of energy data including route planning for meter reading operations • Management and analysis of energy data • Automatic plausibility check and generation of simulated values • Long-term archive with versioning, compression and consolidation functions • Measured value editor for entering and processing energy and operating values • Trender for presenting up-to-date (online) and historical load curves (trends), also for setpoint/actual value analyses • Energy management dashboards for creating cross-company transparency through visualization of parameters and display of Sankey diagrams. Siemens ST 80 / ST PC · 2013 4/53 4 © Siemens AG 2013 HMI Software Software for energy management SIMATIC B.Data ■ Function (continued) Energy and material balance Freely parameterizable balancing of the energy flows of various media such as electricity, heat, gas, steam, and emissions (CO2) in the B.Data Plant Explorer • Calculation of characteristic values (KPIs, efficiency coefficients, etc.) with direct reference to production (batches, quantities, etc.). 4 Energy accounting (costs and revenue accounting) Calculation and allocation/assignment of energy costs to plants and/or customers/cost units in accordance with the costs-bycause principle. The bottom up (measurement) and top down (allocation) procedures are supported here • Flexible modeling of the hierarchic accounting structures in the Plant Explorer • Tariff allocation of quantities, flexible price assessment with tariff and price time series • Transfer of costs/revenues to the ERP system (e.g. SAP R/3 CO) 10% 90% Consumption area (e.g.: Building 1) 20% 1 ... n 75% 80% Consumption area (e.g.: Building 2) 25% Counter 1 Counter 3 Counter 2 4/54 Siemens ST 80 / ST PC · 2013 Factors are based on: • Numbers of employees • Area data • Allocation formula • etc. 100% Distribution ensured G_ST80_XX_00380 Accounting area (e.g. Cost center) Losses Energy planning • Generation of requirement forecasts based on productiondependent factors (production planning) and basic load profiles (typical days) • Generation of energy schedules for registering with the energy suppliers. Energy reporting • Freely parameterizable report generator for creating balances, protocols, shift logs, bills • Fully automated reporting with task management, e-mail dispatch and document management • B.Data Intranet/Internet viewer (web client) for company-wide viewing of reports and results • Information about discrepancies from specified parameters through KPI warning system © Siemens AG 2013 HMI Software Software for energy management SIMATIC B.Data ■ Technical specifications ■ Ordering data SIMATIC B.Data V5.3 SP2 2) Operating system • Windows Server 2003 SP2 32 bit Eng./Ger. • Windows Server 2008 Std. Edition 32 bit Eng./Ger. • Windows Server 2008 R2 Eng./Ger. • Windows XP Professional SP3 32 bit Eng./Ger. • Windows 7 Professional/Ultimate 32 bit/64 bit Eng./Ger. • Minimum of 2 GB RAM Interface In addition to an interface to WinCC, B.Data also offers the latest interface standards, such as OPC, ODBC, ASCII and XML. WinCC versions 1) • SIMATIC WinCC V7.0 SP3, V7.2 • SIMATIC WinCC RT Professional V11 SP2, V12 PCS 7 versions 3) • SIMATIC PCS 7 V8.0 SP1 1) If an acquisition computer is installed on a WinCC system, these requirements must also be complied with. 2) The SIMATIC B.Data V5.3 Basic System is delivered with an Oracle Database Standard Edition Embedded. For larger quantity frameworks (as of 250 million stored measured values), you need Oracle Database Enterprise Edition with Partitioning Option, which must be ordered separately from Oracle. 3) The SIMATIC B.Data system for connection to the PCS 7 must always be installed on a separate PC. ■ More information Further information can be found on the Internet at: www.siemens.com/simatic-bdata Order No. SIMATIC B.Data V5.3 SP2 Basic System In the basic system of B.Data, the following components are already included: One B.Data acquisition component (WinCC, OPC, etc.), 1 B.Data client, B.Data Data Mobile, ERP interface, Reporting, Trender, Visu, document management, Matrix, KPI, Profile • Basic system, 100 tags1) • SUS for 100 tags2) • Basic system, 500 tags1) • SUS for 500 tags2) • Basic system, 1 000 tags1) • SUS for 1 000 tags2) • Basic system, 30 000 tags1) • SUS for 30 000 tags2) SIMATIC B.Data V5 Powerpack • Basic system, Powerpack 1) Tag upgrade by 1 level • SUS and support contract for Powerpack 2) SIMATIC B.Data V5.3 Trial License 6AV6372-1DF05-3AX0 6AV6372-1DF00-0AL1 6AV6372-1DF05-3BX0 6AV6372-1DF00-0BL1 6AV6372-1DF05-3CX0 6AV6372-1DF00-0CL1 6AV6372-1DF05-3DX0 6AV6372-1DF00-0DL1 6AV6372-1DF05-3XX0 6AV6372-1DF00-0XL1 6AV6372-1DF15-3AX0 Basic System, 90 days 5) 4 SIMATIC B.Data V5 Expansions 3) The functional scope of B.Data can be expanded with the following packages. SIMATIC B.Data Web Server • incl. 3 web clients • incl. 20 web clients 6AV6372-1DF25-2AX0 6AV6372-1DF25-2BX0 SIMATIC B.Data Client 6AV6372-1DF35-2AX0 SIMATIC B.Data Prognosis & Planning 6AV6372-1DF45-2AX0 SIMATIC B.Data Acquisition Component 6AV6372-1DF55-2AX0 SIMATIC B.Data upgrades • SIMATIC B.Data 100 tags, upgrade V5.2 -> V5.3 SP2 4) • SIMATIC B.Data 500 tags, upgrade V5.2 -> V5.3 SP2 4) • SIMATIC B.Data 1 000 tags, upgrade V5.2 -> V5.3 SP2 4) • SIMATIC B.Data 30 000 tags, upgrade V5.2 -> V5.3 SP2 4) 6AV6372-1DF05-3AX4 6AV6372-1DF05-3BX4 6AV6372-1DF05-3CX4 6AV6372-1DF05-3DX4 1) The SIMATIC B.Data V5.3 Basic System is delivered with an Oracle Database Standard Edition Embedded. For larger quantity frameworks (as of approx. 250 million stored measured values), you need Oracle Database Enterprise Edition with Partitioning Option, which must be ordered separately from Oracle. 2) The SUS contract runs for 1 year. The contract is automatically extended by a further year unless canceled 3 months prior to expiration. 3) B.Data expansions can also be used with B.Data V5.2 (SP1). 4) The upgrades are delivered without Oracle Database Standard Edition Embedded. 5) The trial DVD can also be used to upgrade V5.3 SP1 -> V5.3 SP2. Siemens ST 80 / ST PC · 2013 4/55 © Siemens AG 2013 HMI Software Software for energy management SIMATIC powerrate ■ Overview ■ Benefits • Identification of energy-intensive equipment and processes to develop measures for improving energy efficiency. • Comparison of consumption profiles for more efficient processes. • Optimization of the company according to energy parameters, based on an evaluation of consumption and costs. • Compliance with the contractually agreed power limits, thus preventing higher power supply costs or penalty payments. • Integration of the 7KM PAC3200/4200 measuring devices for a clear overview of selected measured values and alarms. • Integration of switches with an overview of the switch status and the switching possibilities. • Accurate assignment and comparison of the consumption data of specific work processes or batches ■ Design SIMATIC powerrate, as an option for WinCC / PCS 7, ensures transparency in energy consumption from the infeed to the load. 4 SIMATIC powerrate is used in all sectors in which WinCC or PCS 7 are deployed and energy efficiency considerations play a major role. Total integration into WinCC or PCS 7 means that there is no need for a special system environment. Predefined modules and symbols give you the assurance of building on tested product components, with interfaces that support customized expansion. SIMATIC powerrate therefore provides a solution that you can use to obtain an overview of the energy consumption of a plant easily and cost-effectively through integration in an existing SIMATIC SCADA system. 4/56 Siemens ST 80 / ST PC · 2013 SIMATIC powerrate comprises the following components: • Blocks for acquiring and conditioning energy data • Faceplates for displaying and editing energy data • Blocks for implementing load management (calculating the trend, monitoring the limit, releasing/inhibiting loads), batchrelated consumption recording and for integrating measuring instruments and switches • Additional blocks – for example, for time synchronization, data backup, data exchange with archives • Faceplates for displaying results and entering values (e.g. for configuration, or manually measured values) • Excel-based reports for allocating energy data to cost centers, for batch-related evaluation and for determining and displaying the load duration curve • Exporting data to Excel © Siemens AG 2013 HMI Software Software for energy management SIMATIC powerrate ■ Function Acquiring and conditioning energy data Using ready-to-use function blocks, energy data can be acquired by any PROFIBUS-capable devices. The data can be input to the function blocks in the form of counter pulses, count values or power values. Count values can also be entered manually. From this data, the function block calculates the power averages and the work values for a predefined period. This calculated data is subsequently saved in the WinCC archive. In addition, a final value forecast is extrapolated for the power values for each period. A sample function (heat calculation) that can be adapted to the needs of the customer at any time by means of open interfaces has been implemented for the purpose of visualizing customized calculations. Data from manually read counters can be entered directly into the system and used for further analysis. Absolute numerical values (entry of an absolute value instead of the difference from the previous value) can also be recorded and used in further processing. The up-to-date, acquired energy data is displayed as power averages/work values for each time interval (total value for the previous interval, current value of the current interval, extrapolated value for the end of the current interval). A load trend display enables analysis of archived energy data as well as its representation in tables. The archived data can be exported to Excel directly from WinCC using the export functions. The exported energy data can also be included in further customized processing. WinCC tools can be used to access the data from the WinCC archive. For this purpose, selected energy data is read from archives (Tag Logging archive, user archives) from the WinCC Runtime database; using Microsoft Excel the following reports can then be generated: • Cost center report Here the consumption can be allocated to different cost centers and the costs can be calculated on the basis of predefined tariffs. The results can be output by means of 2 reports in the form of tables or diagrams. • Load duration curve An analysis is carried out on the basis of the archived power averages to establish how often a certain power average has occurred in a given period. It can be quickly detected from this characteristic curve whether temporary power peaks exist which can represent a possible starting point for cost savings by means of load management. • Batch report This is used to allocate consumption to batches, whereby the data can be presented in chronological order or in order of batch name. The generation of exports or reports can be activated manually or automatically time-controlled (daily, weekly or monthly). Data access and report generation can also take place via a separate "office" PC; which enables the WinCC installation and the "office" applications to be distributed across different PCs. Contractually agreed power limits (in the case of electricity, normally the 15-minute average power value) must be observed, otherwise significantly higher supply prices or even penalty payments may become due to the energy supply company. The load management feature of SIMATIC powerrate carries out cyclic trend calculations in order to issue warnings/alarms if violation of the limit is likely and to switch off loads in accordance with the given configuration should this be required. If a limit is exceeded despite this, the latest load management data is archived to enable future evaluation or analysis. To prevent unnecessary switching operations, numerous parameters are available for adapting the load management to the current process conditions - and all this can be done easily and conveniently via the faceplate. For loads that are distributed over different PLCs, SIMATIC powerrate contains appropriate PLC-to-PLC communication blocks which can be used to integrate these loads into the load management system. Load management is scalable, according to the maximum number of loads to be integrated or monitored, for up to 10, 25, 50, 75 or 100 loads. Load management can be performed for different media (e.g. electricity, gas) simultaneously. A batch comprises all the units of a product that have been produced in one production cycle, i.e. under identical conditions. Batch-related consumption recording allows accurate recording of energy consumption for each batch. Batch-related consumption recording is possible for five types of energy each with up to 10 loads. Appropriate reports can be generated for analysis of the data (see also the batch report). If the 7KM PAC3200/PAC4200 measuring devices are integrated, selected measured values can be displayed and alarms (current, voltage, pulse frequency too high) can be generated from the digital status information and displayed. Switch integration via digital inputs/outputs (DI/DO) supports display of the switch status (On, Off, tripped, unplugged). With the appropriate authorization, switching is also possible via the faceplate. Switching takes place in a 2-step operation (switch command is issued, followed by a prompt for repeated confirmation; the switch command is not forwarded to the switch until confirmation has been received). Support for the WinCC Web Navigator option also makes the powerrate functionality possible via the web. To avoid data loss in the event of a communication fault, the data is stored temporarily in a circulating buffer on the S7. Siemens ST 80 / ST PC · 2013 4/57 4 © Siemens AG 2013 HMI Software Software for energy management SIMATIC powerrate ■ Technical specifications ■ Ordering data SIMATIC powerrate V4.0 SP1 Hardware requirements SIMATIC powerrate can be used in the PCS 7 or WinCC SCADA environments. For installation, the respective hardware requirements of the following products apply: • PCS 7 • STEP 7 and WinCC SCADA Released CPUs - SIMATIC powerrate is released in the PCS 7 environment for • S7-400 CPUs supported by PCS 7 • WinAC RTX 2010 Released CPUs - SIMATIC powerrate is released in the WinCC SCADA environment for • S7-400 • S7-300 - SIMATIC S7 CPU 319-3 PN/DP V2.5 and higher - SIMATIC S7 CPU 317-2 PN/DP V2.6 and higher - SIMATIC S7 CPU 315-2 PN/DP V3.1 and higher • SIMATIC ET 200S IM151-8 PN/DP CPU V3.2 and higher • WinAC RTX 2010 You can use SIMATIC powerrate in the PCS 7 or WinCC SCADA environments. For installation, the respective software requirements of the following products apply: • PCS 7 • STEP 7 and WinCC SCADA The library is released for the following PCS 7 versions • SIMATIC PCS 7 V8.0 with Update 1 (Europe & ASIA) • SIMATIC PCS 7 V7.1 SP3 The library is released for the following WinCC version with the corresponding versions of STEP 7 • SIMATIC WinCC V7. 0 SP3, SP3 with Update 1 (Europe & ASIA) For use with WinCC V7.0 SP3, the following installations are required • WinCC minimum installation - Basic Process Control - User archives for load management and batch-oriented energy acquisition • WinCC add-on "AS-OS Engineering" For the use of SIMATIC powerrate V4.0, WinCC must execute in integrated mode with STEP 7. • SIMATIC NET • STEP 7 powerrate Reports has been released for the following versions • Microsoft Excel 2003 • Microsoft Excel 2007 • Microsoft Excel 2010 4/58 Order No. 6AV6372-1DE04-0AX0 Also included are • License for user/archive • PAC3200 function block library for WinCC • Block library PAC3200, 3WL/3VL for PCS 7 SIMATIC powerrate V4.0 SP1 upgrade 6AV6372-1DE04-0AX4 Upgrade V3.0 SP1 to V 4.0 SP1, ES + OS-RT1) SIMATIC powerrate V4.0 SP1 update 6AV6372-1DE04-0AX3 Update V4.0 to V 4.0 SP1 SIMATIC powerrate V4.0 SP1 trial license 6AV6372-1DE04-0AX7 Limited 30-day ES + OS Runtime license 1) Software requirements 4 SIMATIC powerrate V4.0 SP1 ES + OS Runtime 1) For operation on a WinCC/PCS 7 OS single-user workstation or server and any number of automation systems. When using additional WinCC/PCS 7 OS single-user stations/servers, one license is required per WinCC/PCS 7 OS single-user station/server. ■ More information Siemens ST 80 / ST PC · 2013 Further information can be found on the Internet at: http://www.siemens.com/simatic-powerrate Important information on the use of SIMATIC powerrate is available on the Internet at: http://support.automation.siemens.com/WW/view/en/48204134/ 133200 © Siemens AG 2013 HMI Software SIMATIC WinCC flexible HMI system SIMATIC WinCC flexible HMI system ■ Overview SIMATIC WinCC flexible ES engineering software • Family of configuration systems with WinCC flexible Micro/ Compact/Standard/Advanced for SIMATIC operator panels, the HMI part of SIMATIC C7 as well as for the PC-based visualization software WinCC flexible Runtime • Runs under Windows XP Professional / Windows 7 Professional, Ultimate, Enterprise • Can be expanded by the option "WinCC flexible /ChangeControl" for version management and change logging SIMATIC WinCC flexible Runtime visualization software • Modular PC-based HMI solution for single-user systems directly at the machine (further development of ProTool/Pro RT) • Runs under Windows XP Professional / Windows 7 Professional, Ultimate, Enterprise • Basic package for visualization, reporting and logging; can be expanded by implementing option packages • Flexible expansion possible with VB scripts and customized ActiveX controls created with OPP (Open Platform Program) • Can be integrated into automation solutions based on TCP/IP networks • Expanded service concepts with remote operation, diagnostics and administration over the intranet and Internet in combination with email communication 4 Siemens ST 80 / ST PC · 2013 4/59 © Siemens AG 2013 HMI Software SIMATIC WinCC flexible HMI system SIMATIC WinCC flexible ES ■ Overview ■ Application SIMATIC WinCC flexible Micro/Compact/Standard/Advanced are engineering tools for configuring SIMATIC HMI devices, the operating component of SIMATIC C7 devices, the SIMOTION/ SINUMERIK Panel PCs as well as the PC-based visualization system WinCC flexible Runtime. Depending on the selected product, various target systems can be configured: WinCC flexible Micro • Micro Panels: OP 73micro, TP 170micro, TP 177micro WinCC flexible Compact 4 • Uniform family of engineering tools for configuration SIMATIC HMI Operator Panels, the operator control part of SIMATIC C7 units, SIMOTION/SINUMERIK Panel PCs as well as the PC-based visualization software WinCC flexible Runtime. • Runs under Windows XP Professional / Windows 7 Professional, Ultimate, Enterprise • Current version: - SIMATIC WinCC flexible 2008 SP3 Micro - SIMATIC WinCC flexible 2008 SP3 Compact - SIMATIC WinCC flexible 2008 SP3 Standard - SIMATIC WinCC flexible 2008 SP3 Advanced WinCC flexible Standard In addition to the target systems that are configured using WinCC flexible Compact: • Mobile Panels: Mobile Panel 277 • 270 series Panels: TP 270, TP 277, OP 270, OP 277 • 270 series Multi Panels: MP 270B, MP 277 • 370 series Multi Panels: MP 370, MP 377 • C7 devices: C7-636 (Touch/Key) WinCC flexible Advanced ■ Benefits • The integrated configuration software reduces training, maintenance and service overhead and protects the customer's investments • Minimized configuration overhead due to reuse of scalable and dynamizable objects • Tools for efficient and simple configuration: - Wizard for defining the basic structure of the HMI project - Table-based editors simplify the generation and processing of similar types of object, e.g. for tags, texts, or alarms. - Complex configuration tasks such as the definition of paths of motion or the creation of the fundamental operator prompting are simplified by means of graphical configuration. • Comprehensive support of multi-language configurations for worldwide use - Selectable views for entering configuration data in several languages - System and user-specific text lexicons - Export/import of language-dependent texts 4/60 In addition to the target systems that are configured using WinCC flexible Micro: • Basic Panels: KTP400 Basic, KTP600 Basic, KTP1000 Basic, TP1500 Basic • Mobile Panels: Mobile Panel 170, Mobile Panel 177 • 70 series Panels: OP 73, OP 77A, OP 77B • 170 series Panels: TP 170A, TP 177A, TP 170B, TP 177B, OP 170B, OP 177B • 170 series Multi Panels: MP 177 • C7 devices: C7-635 (Touch/Key) Siemens ST 80 / ST PC · 2013 In addition to the target systems that are configured using WinCC flexible Standard: • Standard PC • SIMATIC Panel PC: Panel PC IL 70, Panel PC IL 77, Panel PC 477/477B, Panel PC 577/577B, Panel PC 670, Panel PC 677/677B, Panel PC 870, Panel PC 877 • SIMOTION Panel PC: P012K, P012T, P015K, P015T, PCR, PCR-Touch • SINUMERIK Panel PC: HT8, OP08T, OP010, OP012, TP012, OP015, TP015, OP015A For configuring panels released after the start of delivery of WinCC flexible 2008, an HSP (Hardware Support Package) is required that can be downloaded free of charge via the following link: http://www.siemens.com/wincc-flexible-hsp © Siemens AG 2013 HMI Software SIMATIC WinCC flexible HMI system SIMATIC WinCC flexible ES ■ Design The engineering tools of the SIMATIC WinCC flexible range are based on one another. The available editors largely depend on the respectively configured target systems and their functions. A more comprehensive engineering tool such as WinCC flexible Standard also offers the facilities of the smaller engineering tools, e.g. WinCC flexible Compact or Micro. Upgrading of a smaller engineering tool to a larger one is possible using a Powerpack. An exception is WinCC flexible Micro. The scope of functions of the WinCC flexible engineering tools already includes project support for the Runtime options available for SIMATIC Panels or WinCC flexible Runtime, independent of the RT licenses purchased. Separate licensing is required for the target system in order to use the configured Runtime options. ■ Function Integration into automation systems • Integration into SIMATIC STEP 7 V5.x and Simotion - Management of HMI projects within the SIMATIC Manager - Shared use of communication settings and process point definitions, i.e., symbols and messages - Display of the HMI configuring objects in the SIMATIC Manager - Transfer of configuring data via MPI/PROFIBUS/Ethernet using routing Configuration interface • Comprehensive and fast access to editors and project data via Workbench applications • Adaptive user interface of engineering tools depending on configured target system • User-definable user interface settings, e.g., layout, toolbars, object defaults Project handling • Device-independent configuration data can be used on a variety of target systems without the need for conversion; the interface adapts to the functional possibilities of the device currently configured. • Cross-device utilization of common configuration data (e.g., text library) in multi-device projects • Wizard-assisted definition of basic structure of HMI projects (e.g., display layout, operator prompting) Screen editor with extensive options for efficient and fast screen configuration • Generation of interconnected screen objects via Drag&Drop, e.g., tags for the creation of input/output fields with process interfacing or buttons with screen selection function • Template for the definition of global screen objects and functions (comparable with the Slide Master in MS PowerPoint) • User-friendly editor for the creation of image blocks with defined external interface from screen objects • Graphics-based configuration of motion paths • Layer technology with up to 32 layers • Tools for the Align, Rotate and Mirror functions Import/export • of texts for translation • of tags, links, text lists, and messages • Generation of variable lists for importing from controller programming tools Object-based data management with user-friendly search and edit options • Cross-reference list with direct access to all objects, e.g. for editing or selection • Search for objects in entire project • Central reassignment of variables • Text search and replace functions Libraries for predefined/user-defined configuration objects • Large number of scalable and dynamizable screen objects included in scope of delivery • Size-scalable WMF-format graphics for industrial applications included in scope of delivery • Preview function for library objects • Storage of all engineering objects in library, e.g., blocks and even entire displays or variables; picture blocks can be created on a customer- or projectspecific basis by combining simple screen objects. Changes to these picture blocks can be made centrally (block definition). Language support • Multilingual project creation (max. 32 languages) in editors thanks to selectable views • Automatic translation on basis of system- and user-specific dictionaries in central text library • Central management of language-specific texts and graphics in libraries • Edit, export and import of texts for translation • Language-specific graphics Visual Basic Script support • IntelliSense function for fast programming of access to runtime objects • Simple creation of control sequences in script code; • Script debugging in Simulator and WinCC flexible Runtime Test and startup support • Simulation of HMI projects on engineering PC • Jump to error cause based on alarm messages in the Compiler • Advanced ProSave service tool for all operating systems supported by WinCC flexible ChangeControl (option) • Version management of project versions with rollback • Logging of configuration changes, e.g., for regulated industries Note: For further information, refer to "WinCC flexible options". Default runtime data in engineering tools • Users and passwords • Recipe data records Siemens ST 80 / ST PC · 2013 4/61 4 © Siemens AG 2013 HMI Software SIMATIC WinCC flexible HMI system SIMATIC WinCC flexible ES ■ Technical specifications System requirements (minimum requirements) WinCC flexible Engineering Software Operating system Windows XP Professional SP3 (32 bit), Windows 7 Professional, Ultimate, Enterprise (32 and 64 bit) Additionally for SIMATIC WinCC flexible Micro: Windows XP Home SP3 Processor Pentium 4 (or comparable) processor running at 1.6 GHz or faster Resolution 1024 x 768 or higher Main memory (RAM) ≥ 1 GB, ≥ 512 MB for WinCC flexible Micro Hard disk (free memory space) 1) ≥ 2 GB 2) ≥ 1.2 GB for WinCC flexible Micro 3) DVD drive for software installation ■ Ordering data 4 6AV6610-0AA01-3CA8 WinCC flexible 2008 Compact incl. SP3 Floating license, license key on USB stick, software and documentation on DVD, contains: • Engineering software for configuring Micro Panels, Basic Panels and 70/170 series Panels incl. C7-635 • Software for WinCC flexible /ChangeControl engineering option 1) • Simulation software for Micro Panels, Basic Panels, and 70/170 series Panels incl. C7-635 • Native drivers 6AV6611-0AA51-3CA5 2) When installing one language. An additional 200 MB are required for each further language. In the case of different partitions for system and configuration: System partition approx. 700 MB, project partition approx. 1.3 GB. 3) When installing one language. An additional 80 MB are required for each further language. In the case of different partitions for system and configuration: System partition approx. 600 MB, project partition approx. 600 MB. Order No. WinCC flexible 2008 Advanced incl. SP3 Floating license, license key on USB stick, software and documentation on DVD, contains: • Engineering software for configuring WinCC flexible Runtime on basic PCs/Panel PCs as well as Micro Panels, Basic Panels and 70/170/270/370 series Panels incl. C7-635/636 • Software for WinCC flexible /ChangeControl engineering option 1) • Simulation software for WinCC flexible Runtime as well as Micro Panels, Basic Panels, and 70/170/270/370 series Panels incl. C7-635/636 • Native drivers 6AV6613-0AA51-3CA5 • Electronic documentation (.pdf) WinCC flexible /ChangeControl for WinCC flexible 2008 Compact/Standard/Advanced 1) 2) Floating license, option, license key only • Electronic documentation (.pdf) 6AV6612-0AA51-3CA5 • Electronic documentation (.pdf) 1) A separate license for WinCC flexible /ChangeControl must be purchased for each engineering station 2) The ChangeControl option has not been released for integrated operation with STEP 7 4/62 In addition to the space needed by WinCC flexible, Windows also requires space on the hard disk; e.g. for the swap file. The following formula has proven itself in the past: The size of the swap file = 3 x the size of available RAM. For further information, refer to your Windows documentation Order No. WinCC flexible 2008 Micro incl. SP3 Single license, without license key software and documentation on DVD, without license key, contains: • Engineering software for configuration of Micro Panels • Electronic documentation (.pdf) WinCC flexible 2008 Standard incl. SP3 Floating license, license key on USB stick, software and documentation on DVD, contains: • Engineering software for configuring Micro Panels, Basic Panels and 70/170/270/370 series Panels incl. C7-635/636 • Software for WinCC flexible /ChangeControl engineering option 1) • Simulation software for Micro Panels, Basic Panels, and 70/170/270/370 series Panels incl. C7-635/636 • Native drivers 1) Siemens ST 80 / ST PC · 2013 6AV6613-6AA01-3AB5 Powerpacks SIMATIC WinCC flexible Powerpacks Single license, license key only • WinCC flexible 2008 Standard to 2008 Advanced • WinCC flexible 2008 Compact to 2008 Advanced • WinCC flexible 2008 Compact to 2008 Standard 6AV6613-2CD01-3AD5 6AV6613-2BD01-3AD5 6AV6612-2BC01-3AD5 Updates WinCC flexible 2008 Micro Update 2008, 2008 SP1, 2008 SP2 -> 2008 SP3 6AV6610-0AA51-3CU8 WinCC flexible 2008 Compact/Standard/Advanced Update 2008, 2008 SP1, 2008 SP2 -> 2008 SP3 6AV6613-0AA51-3CU8 © Siemens AG 2013 HMI Software SIMATIC WinCC flexible HMI system SIMATIC WinCC flexible ES ■ Ordering data Order No. Upgrades SIMATIC WinCC flexible 2004/2005/2007 to SIMATIC WinCC flexible 2008 incl. SP3 • Upgrade to WinCC flexible 2008 Micro 2) • Upgrade to WinCC flexible 2008 Compact, incl. ChangeControl option 1) • Upgrade to WinCC flexible 2008 Standard, incl. ChangeControl option 1) • Upgrade to WinCC flexible 2008 Advanced, incl. ChangeControl option 1) SIMATIC WinCC flexible ASIA 2004/2005/2007 to SIMATIC WinCC flexible ASIA 2008 incl. SP3 • Upgrade to WinCC flexible 2008 ASIA Standard, incl. ChangeControl option 1) • Upgrade to WinCC flexible 2008 ASIA Advanced, incl. ChangeControl option 1) 6AV6610-0AA01-3CE8 6AV6611-0AA51-3CE5 6AV6612-0AA51-3CE5 6AV6613-0AA51-3CE5 6AV6613-0AA11-3CA5 • Electronic documentation (.pdf) 6AV6612-0AA11-3CE5 6AV6613-0AA11-3CE5 Versions for China/Taiwan/Korea/Japan WinCC flexible 2008 ASIA Standard incl. SP3 Floating license, license key on USB stick, software and documentation on DVD, contains: • Engineering software for configuring Micro Panels, Basic Panels and 70/170/270/370 series Panels incl. C7-635/636 • Simulation software for Micro Panels, Basic Panels and 70/170/270/370 series Panels incl. C7-635/636 • Native drivers Order No. WinCC flexible 2008 ASIA Advanced incl. SP3 Floating license, license key on USB stick, software and documentation on DVD, contains: • Engineering software for configuring WinCC flexible Runtime as well as Micro Panels, Basic Panels and 70/170/270/370 series Panels incl. C7-635/636 • Software for WinCC flexible /ChangeControl engineering option 1) • Simulation software for WinCC flexible Runtime as well as Micro Panels, Basic Panels, and 70/170/270/370 series Panels incl. C7-635/636 • Native drivers 6AV6612-0AA11-3CA5 • Electronic documentation (.pdf) Documentation (must be ordered separately) User Manual WinCC flexible Communication • German • English • French • Italian • Spanish 6AV6691-1CA01-3AA0 6AV6691-1CA01-3AB0 6AV6691-1CA01-3AC0 6AV6691-1CA01-3AD0 6AV6691-1CA01-3AE0 WinCC flexible Micro User Manual • German • English • French • Italian • Spanish 6AV6691-1AA01-3AA0 6AV6691-1AA01-3AB0 6AV6691-1AA01-3AC0 6AV6691-1AA01-3AD0 6AV6691-1AA01-3AE0 User Manual WinCC flexible Compact/Standard/Advanced • German • English • French • Italian • Spanish 6AV6691-1AB01-3AA0 6AV6691-1AB01-3AB0 6AV6691-1AB01-3AC0 6AV6691-1AB01-3AD0 6AV6691-1AB01-3AE0 4 1) A separate license for WinCC flexible /ChangeControl must be purchased for each engineering station 2) Original delivery note or Certificate of License (CoL) from previous WinCC flexible Micro is required ■ More information Additional information is available in the Internet under: http://www.siemens.com/wincc-flexible Note Do you require a specific modification or extension to the products described here? You will find information about the Open Platform Program for the creation of user-specific functions and controls for WinCC flexible under "Customized Products". Siemens ST 80 / ST PC · 2013 4/63 © Siemens AG 2013 HMI Software SIMATIC WinCC flexible HMI system SIMATIC WinCC flexible RT ■ Overview ■ Application SIMATIC WinCC flexible Runtime is the high-performance visualization software for simple visualization tasks at machine level. It can be used as a single-user solution for all automation applications in factory automation, process automation and building services automation. 4 PC-based visualization software for single-user systems directly at the machine. • Runs under Windows XP Professional and Windows 7 Professional, Ultimate, Enterprise • Current version: SIMATIC WinCC flexible 2008 SP3 Runtime SIMATIC WinCC flexible Runtime is configured with the SIMATIC WinCC flexible Advanced configuration software. ■ Benefits • Optimum price/performance ratio thanks to individually scalable system functionality • Functions for all visualization tasks: Operator functions, graphical and trend displays, signaling system, log system, archiving (option), recipe management (option), Audit Trail (option), process fault diagnostics (option) • Flexible runtime functionality thanks to Visual Basic scripts • Innovative service concepts with remote operation, diagnostics and administration via intranet and Internet as well as e-mail communication to increase availability (option) • Support for simple distributed automation solutions based on TCP/IP networks at the machine level (option) 4/64 Siemens ST 80 / ST PC · 2013 SIMATIC WinCC flexible Runtime can be used in combination with the following operator panels: • SIMATIC Panel PCs - PC IL 70/77 - Microbox 420 - Panel PC 477 - Panel PC 577 - Panel PC 670/677 - Panel PC 870/877 • SIMOTION Panel PCs - P012, P015 - PCR, PCR-Touch • SINUMERIK Panel PCs - HT8; OP08T - OP010, OP012, OP015 - TP012, TP015, OP015A • Standard PCs with resolutions (W x H in pixels) of: - 4:3 format: 640 x 480, 800 x 600, 1024 x 768, 1280 x 1024, 1600 x 1200 - Widescreen format: 800 x 480, 1280 x 800, 1366 x 768, 1440 x 900, 1680 x 1050, 1920 x 1080, 1920 x 1200, 1980 x 1080 ■ Design SIMATIC WinCC flexible Runtime is available as a software package with 128, 512, 2048 or 4096 PowerTags. The term PowerTags is used exclusively to identify process variables and range pointers that have a process link to the controller. Variables without process link, constant limit values of variables, and messages (up to 4000 bit-triggered messages) are also available for additional system performance. The range of functions of WinCC flexible Runtime includes the centralized HMI components for visualizing and reporting, and it can be expanded to suit requirements and costs by using optional packages. SIMATIC WinCC flexible Runtime is configured with the SIMATIC WinCC flexible Advanced configuration software. © Siemens AG 2013 HMI Software SIMATIC WinCC flexible HMI system SIMATIC WinCC flexible RT ■ Function Visualization via Windows-compliant operator interface made up of parameterizable screen objects and image blocks created on a project-specific basis: • Numeric and alphanumeric input/output fields • Static text and graphic display plus vector graphics • Dynamizable graphics from HMI symbol library • Bar graph, trend curve graph with scroll and zoom function as well as read line • Signal-specific text and graphic lists • Buttons and switches for operator-process communication • Editing fields for process values (signals) • Analog display, slider as example for further screen objects • Project-specific image blocks created from system basic objects • Graphic displays for various standard graphic formats, e.g., bitmaps, .jpg, .wmf Alarms and messages • Discrete alarms and analog alarms as well as event-driven Alarm-S/Alarm-D message procedure with SIMATIC S7 and SIMOTION • Freely-definable message classes for definition of acknowledgment response and display of message events Logging of alarms and process values 1) • Archiving in files (e.g. CSV or TXT file) and Microsoft SQL databases • Online evaluation of process value archives and alarm logs • Evaluation of process value archives and alarm logs using standard Microsoft tools such as Excel Recipes 1) • Generation of data records for machine or production data • Display or entry of data records via a configurable screen object or via process images when distributed within the project • Transmission of data records from or to the PLC • Import/export for data records from/to CSV files Documentation of process data, alarm events and recipes • Time- or event-driven report output • User-definable layout Flexible expansion of system function • thanks to Visual Basic Script Language support for multilingual projects • Up to 16 online languages (incl. Asian and Cyrillic) • Language-dependent texts and graphics • Language selection during runtime User-oriented access protection according to requirements of regulated sectors • Authentication with user ID and password • User-group-specific rights • Central system-wide user administration based on SIMATIC Logon 1) • Monitoring of changes by operators in runtime operation 1) • Recording of operator actions in an Audit Trail 1) PLC link for a wide variety of PLCs on-board • Simultaneous connection using several protocols: OPC Client or SIMATIC HMI HTTP protocol are additive, i.e. can be used in conjunction with other PLC links • Communication via native drivers and standard OPC channel Open communication between HMI systems and with higher-level systems 1) • OPC server • Sm@rtAccess for communication between HMI systems based on Ethernet networks, or via the intranet/Internet: • Read and write access to variables; WinCC flexible Runtime or SIMATIC Panels make data (variables) available to other SIMATIC HMI systems or Office applications. • A SIMATIC HMI system can be used to control or monitor another system remotely; entry level for client/server configurations for distributed operator stations or for solutions with headend or control room. Sm@rtService for remote control, diagnostics and administration via intranet and Internet 1) • Display and control of process images on remote PC or Panel • Sending of e-mails on demand or event-driven • System diagnostics visualized via device-specific HTML pages 1) Option for SIMATIC WinCC flexible Runtime; runtime licenses must be purchased separately. For further information, refer to "WinCC flexible options". System requirements WinCC flexible Runtime Operating system Windows XP Professional SP3 (32 bit) Windows XP Embedded 1) Windows 7 Professional / Ultimate / Enterprise (32 bit and 64 bit) Processor 4) • Minimum Windows XP: 300 MHz Windows 7: 1 GHz Windows XP: ≥ Pentium III, 500 MHz Windows 7: ≥ 1 GHz • Recommended Graphics • Minimum • Resolution SVGA 640 x 480 to 1600 x 1200 or 800 x 480 to 1980 x 1080 RAM 2) • Minimum Windows XP: 128 MB Windows 7: 1 GB Windows XP: ≥ 512 MB Windows 7: ≥ 1 GB • Recommended Hard disk (free memory space) 3) ≥ 250 MB 1) Only for enabled platforms (e.g. Panel PC 477). You can get information from your Siemens contact. 2) RAM requirements are determined primarily by the size of the graphics used. 3) Without taking archives into account. In addition to the space needed by WinCC flexible, Windows also requires space on the hard disk; e.g., for the swap file. The following formula has proven itself in the past: The size of the swap file = 3 x the size of the RAM. For further information, refer to your Windows documentation 4) More powerful systems (Pentium 4 and higher) may be required in order to use options Siemens ST 80 / ST PC · 2013 4/65 4 © Siemens AG 2013 HMI Software SIMATIC WinCC flexible HMI system SIMATIC WinCC flexible RT ■ Integration SIMATIC WinCC flexible Runtime supports linking to: Protocol PC interfaces SIMATIC S5 via AS511 (TTY) COM1/COM2 13) S5-90U SIMATIC 500/505 RS 232/RS 422 S5-90U SIMATIC 505 via PROFIBUS DP S5-100U (CPU 100, 102, 103) SIMATIC 545/555 with CP 5434 S5-115U (CPU 941, 942, 943, 944, 945) SIMOTION 8) S5-135U (CPU 928A, 928B) SINUMERIK 9) S5-155U (CPU 946/947, 948) SIMATIC S5 via PROFIBUS DP S5-115U (CPU 941, 942, 943, 944, 945) CP 5512 2) CP 5611 A2 2) S5-135U (CPU 928A, 928B) S5-155U (CPU 946/947, 948) SIMATIC S7 via PPI CP 5512 2) CP 5611 A2 2) CP 5621 1) CP 5613 A2 CP 5614 A2 PC/PPI adapter 3) S7-200 SIMATIC S7 via MPI S7-200 (except CPU 212) 4) S7-300 S7-400 WinAC Basis (V3.0 and higher) WinAC RTX CP 5512 2) CP 5611 A2 2) CP 5621 1) CP 5711 2) CP 5613 A2 CP 5614 A2 PC adapter USB 6) Teleservice V6.1 SIMATIC S7 via PROFIBUS DP 5) S7-215 4) S7-300 CPUs with integr. PROFIBUS interface S7-300 with CP 342-5 CP 5512 2) CP 5611 A2 2) CP 5621 1) CP 5711 2) CP 5613 A2 CP 5614 A2 S7-400 CPUs with integr. PROFIBUS interface WinAC Basis (V3.0 and higher) CP 5512 2) CP 5611 A2 2) COM1/COM2 Allen Bradley (Ethernet) CP 1612 7) GE Fanuc (SNP/SNPX) COM1/COM2 LG GLOFA GM COM1/COM2 Mitsubishi (FX/MP4) COM1/COM2 Modicon (Modbus) COM1/COM2 Modicon (Modbus TCP/IP) CP 1612 7) OMRON (Link/Multilink) COM1/COM2 OPC 10) 12) Data Access V2.05a (client + server) SIMATIC S7 via Ethernet (TCP/IP) S7-200 with CP 243-1 S7-300 CPUs with integral Ethernet interface CP 1612 7) CP 1613 A2 S7-300 with CP 343-1 S7-400 CPUs with integral Ethernet interface CP 1612 7) Data Access XML V1.00 (client) HTTP communication for data exchange between SIMATIC HMI (client + server) 11) 12) CP 1612 7) 1) WinCC flexible Runtime is passive (DP slave); the function block required for the link is included in the scope of delivery of WinCC flexible 2) For Microbox 427 and Panel PC 477/577/677 via internal MPI/DP interface 3) Only point-to-point to S7-200; no configuration download, operating systems: Windows 2000/XP; Order number: 6ES7 901-3CB30-0AX0 4) Constraint with regard to baud rate for S7-200; see Catalog ST 70 5) WinCC flexible RT is active; communication with S7 functions 6) Only point-to-point to S7-300/-400; No configuration download, operating systems: Windows 2000/XP; order number: 6ES7 972-0CB20-0XA0 (USB) 7) For Microbox 427 and Panel PC 477/577/677/877 via internal Ethernet interface 8) For further information, see Catalog PM 10 9) "SINUMERIK HMI copy license OA" option required; for further information, see Catalog NC 60 10) OPC Client is included in scope of delivery, the "WinCC flexible /OPC Server for WinCC flexible Runtime" license is required for the OPC Server option 11) "WinCC flexible /Sm@rtAccess for WinCC flexible Runtime" license required 12) OPC and HTTP communication are additive, i.e. can be used in conjunction with the PLC links listed above 13) Via PC cable with integrated level converter RS 232/TTY; Order number: 6ES5 734-1BD20 WinAC RTX For information about SIMATIC Panels that support OPC/http communication, see the overview under "System interfaces". S7-400 with CP 443-1 WinAC Basis (V3.0 and higher) WinAC RTX SIMATIC S7 via integrated interface Internal system interface WinAC RTX 4/66 COM1/COM2 Allen Bradley (DF1/DH485) S7-400 with CP 443-5 or IM 467 WinAC Basis (V2.0 and higher) PC interfaces Third-party controllers 1) S5-95U/L2-DP master 4 Protocol SIMATIC 505 NITP Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 HMI Software SIMATIC WinCC flexible HMI system SIMATIC WinCC flexible RT ■ Integration (continued) Application note In parallel with each and every PLC link, WinCC flexible Runtime supports the use of the OPC Client channel; this enables, for example, connection to an SNMP OPC Server for the purpose of visualizing the data stored there. Note: For further information, see "HMI devices/System interfaces" The SNMP OPC Server provides a means of monitoring network components of any type (e.g. switches) which support the SNMP protocol. For further information, see Catalog IK PI. Higher level visualization system OPC Client Industrial Ethernet On-site visualization OPC Server OPC Server 4 OPC Client SIMATIC S7-300 SIMATIC S7-400 3rd party OPC Server Non-Siemens PLCs G_ST80_XX_00077 PROFIBUS SIMATIC WinCC flexible Runtime application example Siemens ST 80 / ST PC · 2013 4/67 © Siemens AG 2013 HMI Software SIMATIC WinCC flexible HMI system SIMATIC WinCC flexible RT ■ Technical specifications Type 4 SIMATIC WinCC flexible Runtime Type SIMATIC WinCC flexible Runtime The specifications are maximum values Password protection • User rights • Number of user groups 32 50 Visual Basic scripts 200 Online languages, max. 16 Displays • Fields per screen • Variables per screen • Static text • Graphics objects • Complex objects per display (e.g. bars) • Trends • Graphics lists 1) • Text lists 1) • Number of entries in symbol tables 500 400 400 30,000 2,000 40 Variables 4,096 3) Messages bit-triggered / analog • Message text (number of characters) • Number of process values per message • Size of message buffer • Pending message events 4,000 / 500 80 8 Archives 4) • Archivable data 100 Process data, messages 500,000 • Max. number of entries per archive (incl. all archive segments) • Archive types 800 500 500 3,500 1,024 500 • Data storage format Short-term archive, sequence archive (max. 400 per archive) CSV (Comma Separated Variable), RDB (Runtime Data Base), interface to MS SQL database Recipes 4) • Elements per recipe • Data records per recipe 1,000 2,000 3) 5,000 2) 4/68 Siemens ST 80 / ST PC · 2013 Communication SIMATIC S7 MPI interface/ PROFIBUS DP interface • Number of connectable stations, max. Depending on the scope of the configuration (communication) from the point of view of WinCC flexible Runtime, as many as 8 connections are possible SIMATIC S7 PPI interface • Number of connectable stations, max. 1 from viewpoint of WinCC flexible Runtime SIMATIC S5 PROFIBUS DP interface • Number of connectable stations, max. 1 from viewpoint of WinCC flexible Runtime Multi-protocol operation Yes, OPC Client or SIMATIC HMI HTTP protocol are additive, i.e. can be used in conjunction with other PLC links 1) Together only 500 text and graphics lists 2) Dependent on memory medium used 3) Dependent on number of licensed PowerTags 4) Option for SIMATIC WinCC flexible Runtime. For further information, refer to "WinCC flexible options". © Siemens AG 2013 HMI Software SIMATIC WinCC flexible HMI system SIMATIC WinCC flexible RT ■ Ordering data SIMATIC WinCC flexible 2008 Runtime for PC systems; incl. SW for PC systems options 1) Single license, on CD-ROM incl. licensing, for: • 128 PowerTags (RT 128) • 512 PowerTags (RT 512) • 2048 PowerTags (RT 2048) • 4096 PowerTags (RT 4096) Order No. 6AV6613-1BA51-3CA0 6AV6613-1DA51-3CA0 6AV6613-1FA51-3CA0 6AV6613-1GA51-3CA0 Powerpacks SIMATIC WinCC flexible 2008 Runtime Single license, only license key for PowerTags, from • 128 to 512 PowerTags • 128 to 2048 PowerTags • 512 to 2048 PowerTags • 128 to 4096 PowerTags • 512 to 4096 PowerTags • 2048 to 4096 PowerTags 6AV6613-4BD01-3AD0 6AV6613-4BF01-3AD0 6AV6613-4DF01-3AD0 6AV6613-4BG01-3AD0 6AV6613-4DG01-3AD0 6AV6613-4FG01-3AD0 Updates SIMATIC WinCC flexible 2008 Runtime Update 2008, 2008 SP1, 2008 SP2 -> 2008 SP3 Order No. Documentation (must be ordered separately) 6AV6613-1XA51-3CU8 User Manual WinCC flexible Runtime • German • English • French • Italian • Spanish 6AV6691-1BA01-3AA0 6AV6691-1BA01-3AB0 6AV6691-1BA01-3AC0 6AV6691-1BA01-3AD0 6AV6691-1BA01-3AE0 User Manual WinCC flexible Communication • German • English • French • Italian • Spanish 6AV6691-1CA01-3AA0 6AV6691-1CA01-3AB0 6AV6691-1CA01-3AC0 6AV6691-1CA01-3AD0 6AV6691-1CA01-3AE0 SIMATIC HMI Manual Collection Electronic documentation, on DVD 6AV6691-1SA01-0AX0 5 languages (English, French, German, Italian and Spanish); contains: all currently available user manuals, device manuals and communication manuals for SIMATIC HMI 4 Upgrades SIMATIC WinCC flexible 2004/2005/2007 Runtime to SIMATIC WinCC flexible 2008 Runtime • Upgrade to SIMATIC WinCC flexible Runtime 2008 PowerTags incl. Runtime Options for: - WinCC flexible /Archives 6AV6613-1XA51-3CE0 - WinCC flexible /Recipes - WinCC flexible /Audit - WinCC flexible /Sm@rtAccess - WinCC flexible /Sm@rtService - WinCC flexible /OPC server - WinCC flexible /ProAgent • Upgrade of the SIMATIC WinCC flexible Panel options: - WinCC flexible /Audit for SIMATIC Panel - WinCC flexible /Sm@rtAccess for SIMATIC Panel - WinCC flexible /Sm@rtService for SIMATIC Panel - WinCC flexible /OPC server for SIMATIC Multi Panel - WinCC flexible /ProAgent for SIMATIC Multi Panel 6AV6618-7XX01-3AF0 1) Runtime licenses for WinCC flexible Runtime options must be purchased separately for each target system. Siemens ST 80 / ST PC · 2013 4/69 © Siemens AG 2013 HMI Software SIMATIC WinCC flexible HMI system SIMATIC WinCC flexible RT ■ Ordering data Order No. Communication via Industrial Ethernet CP 1613-A2 PCI card (32-bit) for connecting a PG/PC to Industrial Ethernet (communications software must be ordered separately) SIMATIC NET IE S7-1613 V8.0 SP1 Software for S7 and open communication, incl. PG/OP communication, OPC server and NCM PC; up to 120 connections, Runtime software, software and electronic manual on CD-ROM, license key on USB flash drive, Class A, for 32-bit Windows 7 Professional/Ultimate for up to 4 CP 1613/CP 1613 A2 / CP 1623; English/German • Single license for 1 installation • Software Update Service for one year, with automatic extension; requirement: Current software version • Upgrade S7-1613 from V6.4 to S7-1613 V8.0 SP1 • Upgrade S7-1613 from V6.0, V6.1, V6.2 or V6.3 to S7-1613 V8.0 SP1 4 6GK1161-3AA01 6GK1716-1CB80-3AA0 6GK1716-1CB00-3AL0 6GK1716-1CB00-3AE0 6GK1716-1CB00-3AE1 Communication via PROFIBUS CP 5613-A2 PCI card (32-bit) for connecting a PC to PROFIBUS (communications software must be ordered separately) 6GK1561-3AA01 CP 5614-A2 PCI card (32-bit) for connecting a PC to PROFIBUS (communications software must be ordered separately) 6GK1561-4AA01 ■ More information Additional information is available in the Internet under: http://www.siemens.com/wincc-flexible Note Do you need a specific modification or option for the products described here? You will find information about the Open Platform Program for the creation of user-specific functions and controls for WinCC flexible under "Customized Products". 4/70 Siemens ST 80 / ST PC · 2013 Order No. SIMATIC NET PB S7-5613 V8.0 SP1 Software for S7 communication, incl. PG and FDL protocol, OPC server and NCM PC; Runtime software, software and electronic manual on USB flash drive, license key on diskette, Class A, for 32-bit Windows 7 Professional/Ultimate for up to 4 CP 5613 A2, CP5614 A2, CP 5603 / CP 5623 / CP 5624; • Single license for 1 installation • Software Update Service for one year, with automatic extension; requirement: Current software version • Upgrade S7-5613 from V6.4 to S7-5613 V8.0 SP1 • Upgrade S7-5613 from V6.0, V6.1, V6.2 or V6.3 to S7-5613 V8.0 SP1 6GK1713-5CB80-3AA0 6GK1713-5CB00-3AL0 6GK1713-5CB00-3AE0 6GK1713-5CB00-3AE1 CP 5512 PCMCIA card (32-bit CARDBUS) for connecting a PG/Notebook to PROFIBUS or MPI (communications software included in WinCC flexible). 6GK1551-2AA00 CP 5611-A2 PCI card (32-bit) for connecting a PG/PC to PROFIBUS (communications software included in WinCC flexible basic package) 6GK1561-1AA01 CP 5611 MPI Comprising CP 5611 A2 (32-bit) and MPI cable, 5 m 6GK1561-1AM01 CP 5621 PCI Express X1 card (32-bit) for connection of PG/PC to PROFIBUS or MPI (communications software included in WinCC flexible basic package) 6GK1562-1AA00 CP 5711 USB adapter (USB V2.0) for connecting a PG or Notebook to PROFIBUS or MPI (2 m USB cable and 5 m MPI cable included) 6GK1571-1AM00 PC/PPI adapter RS 232, 9-pin; male with RS 232/PPI converter, max. 19.2 kbps 6ES7901-3CB30-0XA0 PC adapter USB For use with Windows 2000/XP 6ES7972-0CB20-0XA0 © Siemens AG 2013 HMI Software SIMATIC WinCC flexible options SIMATIC WinCC flexible options ■ Overview Option for SIMATIC WinCC flexible Engineering SIMATIC Logon for WinCC flexible SIMATIC WinCC flexible /ChangeControl Option for connecting PCs with SIMATIC WinCC flexible Runtime and SIMATIC Panels to central user administration. • Creates user administration on a central computer to which one or more WinCC flexible stations can be connected over Ethernet. • With each logging-on/off of a user on one of the connected stations, SIMATIC Logon checks whether a user password has been created and that the required privileges exist. • SIMATIC Logon for WinCC flexible supports the user in combination with the /Audit and /ChangeControl options in meeting requirements in accordance with FDA 21 CFR Part 11 and EU178. WinCC flexible/ChangeControl enables consistent backup of configuration data. The history of changes can be verified down to the last detail for applications requiring interruption-free proof for the complete life cycle of a product. • Delivered customer projects, approved reference states or development stages are managed in a database. • Changes to project data can be integrated without problem into the version management using new versions. • A rollback is possible at any time. SIMATIC WinCC flexible /Archives Archiving of alarms and process values • Archiving in files (e.g. CSV file) and Microsoft SQL databases • Online evaluation of process value archives and alarm logs • Evaluation of process value archives and alarm logs using standard MS tools such as Excel SIMATIC WinCC flexible /Recipes Generation and management of data records for machine or production data • Display or entry of data records via a configurable screen object or via process images when distributed within the project • Transmission of data records from or to the controller • Import/export of data sets as CSV files SIMATIC WinCC flexible /Audit Recording of operator actions in an Audit Trail • Electronic signature for important operator actions relevant to production • The ChangeControl option supports users in respect of tracking modifications to projects. • Audit supports users in meeting special quality requirements, e.g. - Production plant requiring validation according to 21 CFR Part 11 (Food Drug Administration law) - In respect of traceability according to EU 175/2002 (EU directive) SIMATIC WinCC flexible /Sm@rtAccess • Flexible solution for access to HMI systems and process data from any location • Communication between different SIMATIC HMI systems SIMATIC WinCC flexible /Sm@rtService • Remote maintenance and servicing of machines and plant via Internet/intranet • Reduced downtimes for machines and plant with direct remote access • Flexible solution for remote access to machines and plant SIMATIC WinCC flexible /OPC Server • Incorporation of automation components from different vendors into a single automation concept • Communication for data exchange between HMI systems and/or higher-level control system • Communication with applications from different vendors, e.g. MES, ERP or applications in the office sector SIMATIC WinCC flexible /ProAgent • Precise and rapid process fault diagnostics in plant and machines for SIMATIC S7 and SIMATIC HMI • Standardized diagnostics concept for various SIMATIC components • No further configuration overhead for diagnostics functionality • Frees up PLC capacity with regard to memory and program execution time Siemens ST 80 / ST PC · 2013 4/71 4 © Siemens AG 2013 HMI Software SIMATIC WinCC flexible options WinCC flexible /ChangeControl ■ Overview ■ Application • In machine/special machine construction for project management, e.g. delivered customer versions and their modifications • For saving of intermediate states during complex new developments or expansions, with rollback facility • During work for specific orders as basis for calculating costs for modifications • In regulated sectors as proof of state of plants or machines and any modifications made to them ■ Function • Integral GUI for management of project versions (version tree with main line and secondary lines for modified project versions) • Modification log can be activated/deactivated and shows who carried out modifications, and when/which. Modification reasons can be entered as comments ■ Ordering data 4 • Options for the versioning of configuration data and for tracing configuration changes (e.g. as verification in regulated sectors) • For the engineering tool SIMATIC WinCC flexible Compact/Standard/Advanced • One license is required for each configuration computer 1) 6AV6613-6AA01-3AB5 The ChangeControl option has not been released for integrated operation with STEP 7. ■ More information ■ Benefits • Consistent backup of configuration data - Delivered versions, approved reference states or development stages are managed in a database. - Changes to project data can be integrated without problem into the version management using new versions. A rollback is possible at any time. • Tracing of configuration changes - The history of changes can be verified down to the last detail for applications requiring interruption-free proof for the complete life cycle of a product. 4/72 WinCC flexible /ChangeControl for WinCC flexible 2008 Compact/Standard/Advanced 1) Floating License, option, license key only Order No. Siemens ST 80 / ST PC · 2013 Note Do you need a specific modification or option for the products described here? Then look up "Customized products", where you will find information about the Open Platform Program for the creation of user-specific functions and controls for WinCC flexible. © Siemens AG 2013 HMI Software SIMATIC WinCC flexible options WinCC flexible /Archives ■ Overview ■ Function • Time-controlled as well as manual or process-controlled swapping out of process data and messages for long-term archiving • During runtime, swapped out data are read in and selectively analyzed using WinCC flexible Runtime - Presentation and evaluation of archived process data based on a configurable trend display. Reading of the values is facilitated by a read line. - Presentation and evaluation of archived alarms based on a configurable alarm view. - User-friendly navigation in the archives • External evaluation of the archives using MS standard tools • Various archive types are supported: sequence and shortterm archives • Archiving of process values and messages on external, Windows-supported storage media - CSV files - RDB files - Microsoft SQL server via ODBC • Power standard functions permit user-friendly and flexible utilization of the archives • Option for SIMATIC WinCC flexible Runtime for archiving process values and messages • Archiving of process values and messages supports the acquisition and processing of process data from an industrial plant or machine. Evaluation of the archived process data provides information about the operating states of the plant or machine • One license is required per operator station (no license is required for SIMATIC Panels/Multi Panels) ■ Benefits • Message and process value archives permit foresighted diagnostics which prevents downtimes • Early detection of danger or fault states • Increase in product quality and productivity thanks to regular evaluation of process value and message archives ■ Technical specifications Type WinCC flexible /Archives The specifications are maximum values Execution platform SIMATIC WinCC flexible Runtime Archives • Archivable data • Cyclical trigger for archiving process values (variables) • Max. number of entries per archive (incl. sequence archive) • Archive types 100 Process values, messages 1s Further use of archives for evaluation and long-term archiving Record of repeated fault states Optimization of maintenance cycles Ensured quality standards Control of quality as well as production capacity utilization Documentation of process sequence • Data storage format 1) • Circulating archive • Sequence archive (max. 400 per archive) CSV (Comma Separated Variable), RDB (Runtime Data Base) and interface to Microsoft SQL database (database not included in scope of delivery) ■ Application • • • • • • 500,000 1) Dependent on memory medium used ■ Ordering data Order No. WinCC flexible /Archives for WinCC flexible 2008 Runtime 1) Single License, license key only 6AV6618-7ED01-3AB0 WinCC flexible /Archives+ Recipes for WinCC flexible 2008 Runtime 1) Single License for each option, license key only 6AV6618-7GD01-3AB0 1) One license is required for each operator station. A license is not required for the engineering system for configuring the runtime option. ■ More information Note Do you need a specific modification or option for the products described here? Then look up "Customized products", where you will find information about the Open Platform Program for the creation of user-specific functions and controls for WinCC flexible. Siemens ST 80 / ST PC · 2013 4/73 4 © Siemens AG 2013 HMI Software SIMATIC WinCC flexible options WinCC flexible /Recipes ■ Overview ■ Function • Input of data sets (e.g. operating parameters for a machine, production data for a plastics processing machine) in WinCC flexible Runtime, their storage, and passing on to the PLC • Display and input of data sets using a configurable graphics object, or distributed among several process displays within the project • Data set elements are coupled to the process using direct linking of the variables • Transmission of data records from or to the PLC • Powerful interfaces permit synchronized exchange of data with the PLC • Saving of data sets on local media or on remote data servers via networks • Import/export of data sets as CSV files • Logging of data sets, e.g. as batch report/shift report • Convenient and flexible management of data sets using powerful standard functions 4 • Option for SIMATIC WinCC flexible Runtime for managing data records in recipes that contain related machine or production data • The data in a data set can be transferred, for example, from the control unit to the PLC to switch production to a different product variant • One license is required per operator station (no license is required for SIMATIC Panels/Multi Panels) ■ Benefits WinCC flexible recipes and the associated data sets are conveniently created using a separate editor in the WinCC flexible Advanced engineering tool, and assigned default data. A configurable table object is used to display the data during runtime. Furthermore, the individual data set elements can also be directly output for several process displays on the basis of standard input/output boxes. The data can therefore be clearly presented for the operator in technological layers. ■ Technical specifications Type • Generation and management of machine parameters and production data on the basis of data sets, and exchange with the automation equipment, e.g. with the machine • Clear tabular representation of data elements with support of a configurable graphic object, or representation in technical relationships for several process graphics • Simple operator prompting using standard functions • Export/import of data sets for further processing with other tools (e.g. MS Excel) ■ Application • Assignment of plant/machine parameters in the production industry • Batch-oriented production, e.g. in the food or plastics industry WinCC flexible /Recipes The specifications are maximum values Execution platform SIMATIC WinCC flexible Runtime Recipes • Entries per recipe • Data records per recipe • User data length in bytes per data record 1000 2000 1) 5000 2) 8000 KB 2) 1) Dependent on number of licensed PowerTags 2) Dependent on memory medium used ■ Ordering data Order No. WinCC flexible /Recipes for WinCC flexible 2008 Runtime 1) Single License, license key only 6AV6618-7FD01-3AB0 WinCC flexible /Archives+Recipes for WinCC flexible 2008 Runtime 1) Single License for each option, license key only 6AV6618-7GD01-3AB0 1) One license is required for each operator station. A license is not required for the engineering system for configuring the Runtime option. ■ More information Note Do you need a specific modification or option for the products described here? Then look up "Customized products", where you will find information about the Open Platform Program for the creation of user-specific functions and controls for WinCC flexible. 4/74 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 HMI Software SIMATIC WinCC flexible options WinCC flexible /Audit ■ Overview ■ Benefits • Audit supports the user in meeting special quality requirements, e.g., - production plant requiring validation according to 21 CFR Part 11 FDA 2) - in respect of traceability according to EU 175/2002 3) • Entries in the audit trail are allocated to individual users. This ensures that responsibilities can be clearly identified. • The audit trail, stored as a CSV file 1), can be checked via a security mechanism to find out if subsequent changes have been made. • For particularly important user actions, e.g., starting production or loading new recipes, electronic signatures and comments can be configured and then called up and logged during runtime. • Option for SIMATIC WinCC flexible Runtime as well as SIMATIC Panels for recording operations in an audit trail, and electronic signature • The audit trail features a safety mechanism that indicates subsequent manipulation. • An easy-to-use configuration option included as standard in WinCC flexible enables you to set: - The operator actions to be recorded in the audit trail during runtime - The important operator actions requiring electronic signature/comments during runtime • The audit option combined with the WinCC flexible ES ChangeControl option supports the user with plant validation • Available for the following SIMATIC HMI systems: TP/OP 270, TP/OP 277, MP 270B, MP 277, MP 370, MP 377, WinCC flexible Runtime • A license is required for every operator control unit (panel or PC) 1) CSV Comma Separated Values 2) The FDA (Food and Drug Administration) is the American public health authority 3) 21 CFR Part 11- law on plant validation ■ Technical specifications WinCC flexible /Audit • Plug-in flash memory card on the panel Archive for Audit Trail use on the Panel • In the higher-level PC (memory medium) connected to the panel via Ethernet On the PC (storage medium) Archive for Audit Trail use of WinCC flexible Runtime Execution platform SIMATIC Panels Mobile Panel 277, TP/OP 270, TP/OP 277 SIMATIC Multi Panels MP 270B, MP 277, MP 370, MP 377 PCs SIMATIC WinCC flexible Runtime ■ Ordering data Order No. WinCC flexible /Audit for SIMATIC Panels Single license, license key only 6AV6618-7HB01-3AB0 WinCC flexible /Audit for WinCC flexible Runtime 2008 Single license, license key only 6AV6618-7HD01-3AB0 ■ More information Note Do you need a specific modification or option for the products described here? Then look up "Customized products", where you will find information about the Open Platform Program for the creation of user-specific functions and controls for WinCC flexible. Siemens ST 80 / ST PC · 2013 4/75 4 © Siemens AG 2013 HMI Software SIMATIC WinCC flexible options SIMATIC Logon for WinCC flexible ■ Overview ■ Design SIMATIC Logon and SIMATIC Logon Remote Access are installed on a central station. The following WinCC flexible stations are connected to the central station via Ethernet network: • PCs with WinCC flexible Runtime • SIMATIC Panels from the 177 series or higher (panels with Ethernet interface) Licensing The following licenses are required: • SIMATIC Logon basic license • SIMATIC Logon Remote Access license (3-pack license 10-pack license); more than one SIMATIC Logon Remote Access license can be installed. 4 • Option for connecting PCs with SIMATIC WinCC flexible Runtime and SIMATIC Panels to central user administration. • Creates user administration on a central computer to which one or more WinCC flexible stations can be connected over Ethernet. • With each logging-on/off of a user on one of the connected stations, SIMATIC Logon checks whether a user password has been created and that the required privileges exist. • SIMATIC Logon for WinCC flexible supports the user in combination with the /Audit and /ChangeControl options in meeting requirements in accordance with FDA 21 CFR Part 11 and EU178. • Licensing: SIMATIC Logon (basic license) and SIMATIC Logon Remote Access (3-pack license) for connection of 3 WinCC flexible stations to a central user administration. Additional stations can be connected by using further SIMATIC Logon Remote Access licenses (3-pack/10-pack). ■ Benefits • Centralized configuration of all access authorizations of a distributed system avoids unnecessary travel times. Timeconsuming multiple configurations for each individual local station become unnecessary. Accordingly, users can be easily configured from a central location. • All access data apply throughout the plant on every connected station. Additional access data on local subsystems is no longer necessary. The number of connectable stations depends on the SIMATIC Logon Remote Access licenses used. This number is the total of the connections provided by the individual licenses. As an example: Two installed licenses for 10 enable the connection of 20 stations to the central station. ■ Function Configuration In the first step, the following data must be saved in the user administration of WinCC flexible on every WinCC flexible station in the plant: • Required user groups with associated user privileges • IP address, port number, Windows domain of the central station on which the central user administration is stored. All user groups are configured with the same names in the central user administration. All users are created here, and have automatic access to the connected WinCC flexible stations in accordance with the relevant user group. If the connection fails between the central station with SIMATIC Logon and a WinCC flexible station, the operation is handled through an "emergency user" which must first be preconfigured locally. Intervals for password aging and regulations for the structure of a password are defined according to the configuration on the central station and then also apply to all decentrally connected WinCC flexible stations or the respective users. ■ Technical specifications SIMATIC Logon for WinCC flexible Execution platform 4/76 Siemens ST 80 / ST PC · 2013 SIMATIC Panels Mobile Panel 177 PN; Mobile Panel 277, TP/OP 177B PN/DP, TP/OP 277 SIMATIC Multi Panels MP 177, MP 277, MP 377 PCs WinCC flexible Runtime © Siemens AG 2013 HMI Software SIMATIC WinCC flexible options SIMATIC Logon for WinCC flexible ■ Ordering data Order No. SIMATIC Logon V1.5 Basic license; for panels or WinCC flexible Runtime stations, the corresponding number of additional SIMATIC Logon Remote Access licenses is required. 6ES7658-7BX51-0YA0 SIMATIC Logon Upgrade to V1.5 6ES7658-7BX51-0YE0 SIMATIC Logon Remote Access for WinCC flexible (3 clients) Remote access for 3 WinCC flexible 2008 clients; single license for 3 remote access clients; type of delivery: CD, license key disk, Certificate of License, Terms and Conditions The number of licensed clients is determined based on the amount of installed SIMATIC logon remote access licenses. 6ES7658-7BA00-2YB0 SIMATIC Logon Remote Access for WinCC flexible (10 clients) Remote access for 10 WinCC flexible 2008 clients; single license for 10 remote access clients; type of delivery: CD, license key disk, Certificate of License, Terms and Conditions The number of licensed clients is determined based on the amount of installed SIMATIC logon remote access licenses. 6ES7658-7BB00-2YB0 ■ More information Note Do you need a specific modification or addition to the products described here? Then take a look under "Customer-specific products". There, we provide information on the Open Platform Program for creating your own functions or Controls for WinCC flexible. 4 Siemens ST 80 / ST PC · 2013 4/77 © Siemens AG 2013 HMI Software SIMATIC WinCC flexible options WinCC flexible /Sm@rtAccess ■ Overview 4 ■ Benefits • Option for SIMATIC WinCC flexible Runtime plus SIMATIC Panels for communication between various SIMATIC HMI systems. • Available for the following SIMATIC HMI systems: - Mobile Panel 177 PN, Mobile Panel 277 - TP 177B PN/DP, OP 177B PN/DP - TP 270, TP 277, OP 270, OP 277 - MP 177, MP 270B, MP 277, MP 370, MP 377 - WinCC flexible Runtime • Communication between HMI systems is established on the basis of Ethernet networks, or via the intranet/Internet: - Read and write access to variables; WinCC flexible Runtime or SIMATIC Panels make data (variables) available to other SIMATIC HMI systems or Office applications. - A SIMATIC HMI system can be used to control or monitor another system remotely; entry level for client/server configurations for distributed operator stations or for solutions with headend or control room. • Local operation, visualization and data processing is as possible as plant-wide access to information or central archiving of process data. Integrated information flows ensure an overview of the status of all processes. • Licensing: The license "WinCC flexible /Sm@rtAccess for Panel" or "WinCC flexible/Sm@rtAccess for WinCC flexible Runtime" must be installed on both the server and client HMI device. Server applications are the options Sm@rtServer, HTTP-Server and SOAP-Server. Client applications are the screen object Sm@rtClient display, and the utilization of the communication driver SIMATIC HTTP protocol. No license is required on the client system for access to a Sm@rtServer using the application Sm@rtClient.EXE or the Microsoft Internet Explorer. A license is also not required for the engineering system for configuring the runtime option. Note: If the operator stations are accessed using the Sm@rtAccess option, suitable protective measures (including IT security such as network segmentation) should be taken in order to ensure safe operation of the system. You will find more information on the topic of Industrial Security on the Internet at: http://www.siemens.com/industrialsecurity 4/78 Siemens ST 80 / ST PC · 2013 • Flexible solution for location-independent access to HMI systems and process data • Reduction in load on fieldbuses: WinCC flexible Runtime as well as SIMATIC Panels permit a control system, for example, to access the process data. The sensitive field level is not loaded by the control level as far as the communications requirements are concerned. The requirements are processed by WinCC flexible Runtime and the SIMATIC Panels. • Simple, fast configuration of communications relationships using the WinCC flexible engineering software ■ Application • Use of machine-level HMI systems as data servers for higherlevel automation components such as control systems or office systems. Process values from different machines, for example, are displayed on a process screen. • Operator control and monitoring of machines covering large areas with several operator stations by one operator • Operator control and monitoring of machine-level HMI systems from one central station (e.g. head-end station of a production line or from a control room) © Siemens AG 2013 HMI Software SIMATIC WinCC flexible options WinCC flexible /Sm@rtAccess ■ Application (continued) Master Control Station HTTP Data Client SIMATIC HMI HTTP Protocol Industrial Ethernet Server 1 Server 2 HTTP-Data Server/Client HTTP-Data Server/Client Server 3 Server 4 HTTP-Data Server/Client HTTP-Data Server/Client G_ST80_XX_00070 PROFIBUS Communication between HMI systems via Industrial Ethernet: Use of machine-level HMI systems as data servers for higher-level automation components Sm@rtServer Master Station Sm@rtClient Operator Station 1 Operator Station 2 Operator Station n G_ST80_XX_00071 ... Industrial Ethernet Application of the Sm@rtClient concept: Coordinated operation of several operator stations Siemens ST 80 / ST PC · 2013 4/79 4 © Siemens AG 2013 HMI Software SIMATIC WinCC flexible options WinCC flexible /Sm@rtAccess ■ Application (continued) Master Control Station Sm@rtClient display Industrial Ethernet Server 1 Sm@rtServer Server 2 Sm@rtServer Server 3 Server 4 Sm@rtServer Sm@rtServer G_ST80_XX_00072 PROFIBUS 4 Use of the Sm@rtClient display: Operator control and monitoring of machine-level HMI systems from one central station ■ Function Communication between different SIMATIC HMI systems or between the units of a machine or plant is carried out via Industrial Ethernet or intranet/Internet on the basis of Sm@rtAccess Possible communication relationships: • Reading and writing the variables of a SIMATIC HMI system on the basis of an HTTP protocol - Reading and writing the variables of different HMI systems - Simple configuring of variables in the HMI client configuration using browsers in the WinCC flexible engineering tool - Reading and writing the variables of an HMI system using standard applications such as MS Excel. Communication is made possible by embedding a script in the application, on the basis of the SOAP protocol (Simple Object Access Protocol) superimposed by HTTP 4/80 Siemens ST 80 / ST PC · 2013 • Remote control of an operator station; the HMI application and communication with the PLC are via the master station. In the case of spatially distributed machines/plants (which require a larger number of operator panels), so-called Sm@rtClients can be activated from here which are then assigned access to the master station and thus to the process. Access procedures guarantee that only one operator system can actively access the process at a time. - A configurable graphic object (Sm@rtClient display) embedded in process displays represents the screen of the associated HMI system (Sm@rtServers) - Powerful standard functions permit convenient and flexible operation of the display Password protection can be optionally activated for access to variables or for remote operation of an HMI system. © Siemens AG 2013 HMI Software SIMATIC WinCC flexible options WinCC flexible /Sm@rtAccess ■ Technical specifications Type ■ Ordering data WinCC flexible /Sm@rtAccess The specifications are maximum values Execution platform • SIMATIC Panels • SIMATIC Multi Panels • PCs Mobile Panel 177 PN, Mobile Panel 277, TP/OP 177B PN/DP, TP/OP 270, TP/OP 277 MP 177, MP 270B, MP 277, MP 370, MP 377 WinCC flexible Runtime Sm@rtAccess SIMATIC HMI HTTP protocol Number of connections for one client • Mobile Panel 177 PN, TP/OP 177 B PN/DP, MP 177 as HTTP server • Mobile Panel 277, TP/OP 270, TP/OP 277, MP 270B, MP 277, MP 370, MP 377 as HTTP server • for WinCC flexible Runtime 4 8 16 Sm@rtAccess Sm@rtClient concept Number of Sm@rtClients that can connect to a Sm@rtServer at the same time1) 2) • Mobile Panel 177 PN, TP/OP 177B PN/DP, MP 177 as Sm@rtServer • Mobile Panel 277, TP/OP 270, TP/OP 277, MP 270B, MP 277 as Sm@rtServer • MP 370, MP 377 as Sm@rtServer • for WinCC flexible Runtime as Sm@rtServer Number of Sm@rtClient displays per screen • for Panels/Multi Panels • for WinCC flexible Runtime Order No. WinCC flexible /Sm@rtAccess for SIMATIC Panel 1) Single license, license key only 6AV6618-7AB01-3AB0 WinCC flexible /Sm@rtAccess for WinCC flexible 2008 Runtime 1) Single license, license key only 6AV6618-7AD01-3AB0 1) The license must be installed on the server and on the client HMI device. Server applications are the options Sm@rtServer, HTTP-Server and SOAP-Server. Client applications are the screen object Sm@rtClient display, and the utilization of the communication driver HTTP protocol. A license is not required for the engineering system for configuring the runtime option. ■ More information Note Do you need a specific modification or option for the products described here? Then look up "Customized products", where you will find information about the Open Platform Program for the creation of user-specific functions and controls for WinCC flexible. 4 2 clients 3 clients for 6" devices 2 clients for 8" and 10" devices 3 clients for 12" devices 2 clients for 15" devices 1 client for 19" devices 5 clients 1 2 1) Including 1 Service Client 2) The Sm@rtServer and the WinCC flexible /Pro Agent option cannot be used simultaneously on OP/TP/MP 270/370. Parallel operation of the runtime options ProAgent, Sm@rtAccess and Sm@rtService is possible in the context of the MP 277 8" and 10" devices, Mobile Panel 277 as well as the MP 377. Limitation: a maximum of 2 clients can be connected simultaneously to a Sm@rtServer. Siemens ST 80 / ST PC · 2013 4/81 © Siemens AG 2013 HMI Software SIMATIC WinCC flexible options WinCC flexible /Sm@rtService ■ Overview ■ Function • Option for SIMATIC WinCC flexible Runtime and SIMATIC Panels for remote maintenance and servicing of machines/plant via the Internet/intranet • Available for the following SIMATIC HMI systems: - Mobile Panel 177 PN, Mobile Panel 277 - TP 177B PN/DP, OP 177B PN/DP - TP 270, TP 277, OP 270, OP 277 - MP 177, MP 270B, MP 277, MP 370, MP 377 - WinCC flexible Runtime • Licensing The "WinCC flexible /Sm@rtService for Panel" license or "WinCC flexible /Sm@rtService for WinCC flexible Runtime" license must be installed on the operator panels that use one of the following options/functions: Sm@rtServer, HTML pages (mini-Web server), e-mail. The remote service PC and engineering system do not require a license for configuration the runtime option. Note If the operator stations are accessed using the Sm@rtService option, suitable protective measures (including IT security such as network segmentation) should be taken in order to ensure safe operation of the system. 4 You will find more information on the topic of Industrial Security on the Internet at: http://www.siemens.com/industrialsecurity ■ Benefits • Fast elimination of faults or downtimes and thus increased productivity by means of global access to machines/systems by the service and maintenance personnel • Avoids the need for site visits ■ Application • Remote maintenance and servicing of machines and plants via Internet/Intranet • Calling of system information, control of target systems, and updating of data sets via Internet/Intranet • Automatic sending of emails to experts for fast elimination of faults 4/82 Siemens ST 80 / ST PC · 2013 Remote operator control and monitoring of SIMATIC HMI systems using Industrial Ethernet and/or via the Intranet/Internet Microsoft Internet Explorer V6.0 SP1 or higher is sufficient for accessing an HMI system. Remote control of an operating station the HMI application and communication with the controller takes place via the HMI system. Using Sm@rtService, the HMI systems in the machines/systems can be serviced remotely. An access process ensures that only one operator (either locally at the machine or remotely via Internet Explorer) can actively access the process at one time. Integrated Web Server to process standard HTML pages The following functions can be accessed from the homepage: • Starting and stopping the HMI runtime for maintenance • Remote access to recipe data sets, passwords and information specific to the HMI system • Access the HMI system files via a file explorer • Download configuration data via the Intranet/Internet • Supplement with own HTML pages Sending e-mails to maintenance personnel via SMTP server (Simple Mail Transfer Protocol) • Events that trigger an e-mail: - Reporting of a message class - Configurable standard functions: Changing the value of a variable, pressing a function key, scripts, etc. • Possible e-mail content - Subject - Message text with process variables - Date/Time • The optional use of e-mail/SMS gateways enables access to standard networks (external service provider required) Standard functions make maintenance and service functionality easier. WinCC flexible allows you to quickly and easily configure maintenance and service functions. Password protection can be activated as an option for accessing the HMI system. Different passwords may be configured for different functions. © Siemens AG 2013 HMI Software SIMATIC WinCC flexible options WinCC flexible /Sm@rtService ■ Function (continued) Engineering Station PC/PG {jwVpw lGz wjVwn jGYaG vGGG GGpVpG GGGGb GGG pzkuVkzs tVy jGXaG vGGG GGtGpG l p pGl G_ST80_XX_00073 pG Remote operator control and monitoring of SIMATIC HMI systems using Industrial Ethernet and/or via the Intranet/Internet nz{_WWWW^] pzkuVkzs tVy wyvmpi|z Remote operator control and monitoring of SIMATIC HMI systems using Industrial Ethernet and/or via the Intranet/Internet zt{wGz pG p pzkuVkzs tV y lG zGwjVwn {jwVpw {jwVpw pzkuVkzs tVy SGtlzS vG pG l G_ST80_XX_00074 wyvmpi|z p z w Remote operator control and monitoring of SIMATIC HMI systems using Industrial Ethernet and/or via the Intranet/Internet nz{_WWWW^\ pzkuVkzs tVy wyvmpi|z Sending e-mails to maintenance personnel via SMTP server (Simple Mail Transfer Protocol) Siemens ST 80 / ST PC · 2013 4/83 4 © Siemens AG 2013 HMI Software SIMATIC WinCC flexible options WinCC flexible /Sm@rtService ■ Technical specifications Type ■ Ordering data WinCC flexible /Sm@rtService Execution platform • SIMATIC Panels • SIMATIC Multi Panels • PCs Mobile Panel 177 PN, Mobile Panel 277, TP 177B PN/DP, OP 177B PN/DP, TP/OP 270, TP/OP 277 MP 177, MP 270B, MP 277, MP 370, MP 377 SIMATIC WinCC flexible Runtime Sm@rtService 1) Remote access via HTML pages • for Panels/Multi Panels Internet Explorer V6.0 SP1 and higher • for WinCC flexible Runtime HTML V1.1 (no support for ActiveX, Java, ASP) HTML V1.1 Sending emails • via SMTP server • Subject, message texts with 250 characters of text per email; date/time of message, message No. 1) 4 The Sm@rtServer and the WinCC flexible /ProAgent option cannot be used simultaneously on OP/TP/MP 270/370. Parallel operation of the runtime options ProAgent, Sm@rtAccess and Sm@rtService is possible in the context of the MP 277 8" and 10" devices, Mobile Panel 277 as well as the MP 377. Limitation: a maximum of 2 clients can be connected with a Sm@rtServer. 4/84 Siemens ST 80 / ST PC · 2013 Order No. WinCC flexible /Sm@rtService for SIMATIC Panels 1) Single license, license key only 6AV6618-7BB01-3AB0 WinCC flexible /Sm@rtService for WinCC flexible Runtime 2008 1) Single license, license key only 6AV6618-7BD01-3AB0 1) The "WinCC flexible /Sm@rtService for Panel" license or "WinCC flexible /Sm@rtService for WinCC flexible Runtime" license must be installed on the operator panels that use one of the following options: Sm@rtServer, HTML pages, e-mail. The remote service PC and engineering system do not require a license for configuration of the Runtime option. ■ More information Note Do you need a specific modification or option for the products described here? Then look up "Customized products", where you will find information about the Open Platform Program for the creation of user-specific functions and controls for WinCC flexible. © Siemens AG 2013 HMI Software SIMATIC WinCC flexible options WinCC flexible /OPC server ■ Overview Higher level visualization system OPC Client Industrial Ethernet On-site visualization OPC Server OPC Server OPC Server Multi Panel OPC Client PROFIBUS SIMATIC S7-300 SIMATIC S7-400 3rd party OPC Server • Option for SIMATIC WinCC flexible Runtime as well as Multi Panels for communication with applications from different vendors (e.g. MES, ERP, or applications in the office sector) G_ST80_XX_00078 3rd party PLCs • Available for the following SIMATIC HMI systems: - Mobile Panel 277, MP 270B, MP 277, MP 370, MP 377 (use of OPC on XML basis) - WinCC flexible Runtime (use of OPC based on DCOM) • One license is required for each operator station. ■ Benefits • Incorporation of automation components from different vendors into an automation concept • Saving of development costs through communication between automation systems based on a homogeneous, uniform protocol • Reduction in load on fieldbuses: WinCC flexible Runtime as well as SIMATIC Panels permit a control system, for example, to access the process data. The sensitive field level is not loaded by the control level as far as the communications requirements are concerned. The requirements are processed by WinCC flexible Runtime and the SIMATIC Panels. ■ Application OPC (OLE for Process Control) is a standardized, open, uniform and multi-vendor software interface. OPC is based on the Windows technology of COM (Component Object Model), DCOM (Distributed COM) or on XML. Windows-based systems such as SIMATIC Panel PC or SIMATIC Multi Panels are used for tasks at the machine and process levels, and can communicate with all OPC-compatible applications via Ethernet using TCP/IP and OPC. WinCC flexible Runtime or the SIMATIC Multi Panel (OPC server) provide data for one or more OPC clients. As a result, local visualization and data processing are possible to the same extent as plant-wide calling of information or archiving of process data. Uniform flows of information guarantee an overview of the status of all processes. Communication with OPC-compatible applications from different vendors (e.g. MES, ERP, or applications in the office sector) is possible. OPC Foundation http://www.opcfoundation.org Siemens ST 80 / ST PC · 2013 4/85 4 © Siemens AG 2013 HMI Software SIMATIC WinCC flexible options WinCC flexible /OPC server ■ Function ■ Ordering data • Use of a visualization system as a data server (OPC server) for higher-level automation components such as control systems or office systems - OPC-XML server for multi panels - OPC server (DCOM) for WinCC flexible Runtime • The WinCC flexible engineering system can conveniently select a desired OPC item from the variables function of the OPC server using an OPC browser (component of the OPC server). To do this, the OPC server must be started and must be accessible for the engineering system. Execution platform • SIMATIC Panels • SIMATIC Multi Panels • PCs OPC server • XML server for Multi Panels 4 • DCOM server for WinCC flexible Runtime • Number of connections that an OPC server can accommodate 1) WinCC flexible /OPC server for WinCC flexible Runtime 2008 1) Single license, license key only 6AV6618-7CD01-3AB0 1) One license is required for each operator station. A license is not required for the engineering system for configuring the Runtime option. WinCC flexible /OPC Server Note The specifications are maximum values Do you need a specific modification or option for the products described here? Then look up "Customized products", where you will find information about the Open Platform Program for the creation of user-specific functions and controls for WinCC flexible. Mobile Panel 277 MP 270B, MP 277, MP 370, MP 377 SIMATIC WinCC flexible Runtime Supports the OPC XML Data Access specification V1.0 1) Supports the OPC Data Access specification V1.0a and V2.0 8 Data access via XML has a functional scope that is similar to OPC Data Access. A software adapter is required that must be installed on the OPC client PC to enable DCOM-based OPC clients to access the OPC XML server without any modification. The software adapter is supplied with WinCC flexible Engineering and Runtime. 4/86 6AV6618-7CC01-3AB0 ■ More information ■ Technical specifications Type Order No. WinCC flexible /OPC Server for SIMATIC Multi Panels 1) Single license, license key only Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 HMI Software SIMATIC WinCC flexible options WinCC flexible /ProAgent ■ Overview ■ Ordering data Order No. WinCC flexible /ProAgent Software option package for process diagnostics based on Functional enhancement for SIMATIC WinCC flexible; electronic documentation in English, French, German, Italian, and Spanish • WinCC flexible /ProAgent for SIMATIC Panels 1) Runtime license (Single License) executable on Mobile Panel 277, TP/OP/MP 270/277 and MP 370/377 • WinCC flexible/ProAgent for WinCC flexible Runtime 2008 1) Runtime license (single license) 67(3 G_ST80_XX_00367 1) • Targeted and rapid process diagnostics in plants and machines for SIMATIC S7 and SIMATIC HMI • Standardized diagnostics concept for various SIMATIC components • No further configuration overhead for diagnostics functionality • Frees up PLC capacity with regard to memory and program execution time 6AV6618-7DB01-3AB0 6AV6618-7DD01-3AB0 One license is required for each operator station. A license is not required for the engineering system for configuring the Runtime option. ■ More information Note Do you need a specific modification or option for the products described here? Then look up "Customized products", where you will find information about the Open Platform Program for the creation of user-specific functions and controls for WinCC flexible. Note For further information, refer to "SIMATIC ProAgent Process Diagnostics Software". Siemens ST 80 / ST PC · 2013 4/87 4 © Siemens AG 2013 HMI Software SCADA system SIMATIC WinCC SIMATIC WinCC ■ Overview Current versions: SIMATIC WinCC V7.2 Executable with: • Windows 7 SP1 (32 / 64 bit) Professional, Enterprise, Ultimate • Windows XP Professional SP3 • Windows Server 2003 SP2, Standard • Windows Server 2008 SP2 (32 bit) Standard • Windows Server 2008 R2 SP1 (64 bit) Standard • contains the Microsoft SQL Server 2008 R2 SP1 (32 bit) SIMATIC WinCC V7.0 SP3 4 • PC-based operator control and monitoring system for visualizing and operating processes, production flows, machines and plants in all sectors – from the simple single-user station through to distributed multi-user systems with redundant servers and cross-location solutions with Web clients. WinCC is the information hub for corporation-wide vertical integration. • The basic system configuration (WinCC basic software) includes industry-standard functions for signaling and acknowledging events, archiving of messages and measured values, logging of all process and configuration data, user administration and visualization. • The WinCC basic software forms the core of a wide range of different applications. Based on the open programming interfaces, a wide range of WinCC options (from Siemens Industry Automation) and WinCC add-ons have been developed (by Siemens-internal and external partners). • WinCC can be operated with every PC that meets the given HW requirements. The SIMATIC Box / Panel PC and SIMATIC Rack PC product range in particular is available for the industrial use of WinCC systems. SIMATIC PCs impress with their powerful PC technology, are designed for round-the-clock operation, and can be operated in both office areas and harsh industrial environments. • SIMATIC WinCC can be ordered in combination with a SIMATIC IPC (Box/Rack/Panel PC) as SIMATIC HMI Package at a price advantage • Together with the SIMATIC IPC427C and IPC477C there are turnkey solutions available as WinCC standard client or single station (see also Packages and IPC427C/IPC477C) 4/88 Siemens ST 80 / ST PC · 2013 Executable with: • Windows 7 SP1 (32 / 64 bit) Professional, Enterprise, Ultimate • Windows XP Professional SP3 • Windows Server 2003 SP2 and Windows Server 2003 R2 SP2 Standard • Windows Server 2008 SP2 (32 bit) Standard • Windows Server 2008 R2 SP1 (64 bit) Standard includes the Microsoft SQL Server 2005 SP4 • Use in virtual environments – for additional information, see http://support.automation.siemens.com/WW/view/en/ 49370459 SIMATIC WinCC V6.2 SP3 Executable with: • Windows XP Professional SP3 • Windows 2000 Professional SP4 • Windows Server 2003 SP2 and Windows Server 2003 R2 SP2 include Microsoft SQL Server 2005 SP2 © Siemens AG 2013 HMI Software SCADA system SIMATIC WinCC SIMATIC WinCC ■ Benefits • All-purpose - Solutions for all sectors - Multilingual for worldwide usage - Can be integrated into all automation solutions • All HMI functions on board - User administration - Operator control and monitoring - Reporting, acknowledging, and archiving of events - Acquisition, compression and archiving of measured values (incl. long-term backup) - Logging and documenting of process and configuration data • Can be configured simply and efficiently - Configuration wizards let the user focus on the essentials - In the picture by means of cross-reference lists and screen property displays - Configuration of multilingual applications - Configuring tool for configuring bulk data • Universally scalable - Expandable from single station to client-server configurations - Increased availability by means of redundant servers - Process visualization via the web with the WinCC WebNavigator • Open standards for simple integration - Powerful real-time database Microsoft SQL Server 2008 R2 SP1 (32 bit) - Open for application modules with ActiveX controls - Visual Basic for Applications for individual expansions - OPC for cross-vendor communication • Process visualization with Plant Intelligence - Integrated high-performance Historian on the basis of the Microsoft SQL Server 2008 R2 SP1 (32 bit) - Integrated evaluation functions for the online analysis (statistical process control) - Production optimization with the help of diverse options • Expandable using options and add-ons - Options for scalable configurations - Options for increasing the availability - Options for IT & business integration - Options for SCADA expansions - Options for validation in accordance with FDA 21 CFR Part 11 - Options for the use of telecontrol protocols • Part of Totally Integrated Automation - Direct access to the tag and message configuration of the SIMATIC control system - Integrated diagnostic functions for increasing productivity - Options for the use of telecontrol protocols New in V7.2 • Expansion into Graphic Designer - Know-how protection by means of password protection for PDL images and image blocks • Unicode support - WinCC SETUP in 5 languages / up to 9 installed languages - Individual language selection for engineering and runtime, regardless of the language settings in the operating system • Simplified configuration of the Tag Management by means of the innovative WinCC Configuration Studio - Configuration options similar to those in Excel - Simplified tags / structure tag management • New communication channels - Communication channel to new CPU (S7-1200 / S7-1500) (absolute address only, no CPU alarming support) - Introduction of the OPC UA server (DA, HDA) • Expansion into archive system - New archive recording (day, weak, year) - New archiving methods (difference) and more ... 4 Siemens ST 80 / ST PC · 2013 4/89 © Siemens AG 2013 HMI Software SCADA system SIMATIC WinCC SIMATIC WinCC ■ Application SIMATIC WinCC is designed for visualization and operation of processes, manufacturing cycles, machines and plants. With its powerful process interface, especially to the SIMATIC family, and the secure data archiving, WinCC enables highly available solutions for the process control. The sector-neutral basic system enables universal usage in all automation applications. Sector-specific solutions can, for example, be implemented using WinCC options (e.g. FDA options for the pharmaceutical industry) and sector-specific add-ons (e.g. for the water industry). ■ Design SIMATIC WinCC is available as a complete package and as a runtime package with 128, 512, 2048, 8192, 65536, 102400, 153600, 262144 PowerTags 1). PowerTags are data points that are connected to controllers or other data sources over a WinCC channel. Up to 32 alarms can be obtained from one data point. Moreover, internal tags without coupling are available for additional system performance. In addition WinCC also contains 512 archive tags. Individual archive licenses can be obtained for greater quantity structures. Licenses for a multi-user configuration 4 The system software with the required number of PowerTags and additionally the option WinCC/Server must be installed on the WinCC server. In the basic configuration, an RT128 or RT client license is sufficient for the WinCC clients. In order to configure on clients, an RC128 or RC client license is required. Remote configuration is possible if WinCC clients without their own project (UniClient) on the server project are configured. 1) ■ Function The powerful configuration functions of SIMATIC WinCC contribute to a reduced engineering and training overhead and lead to a more flexible use of personnel and greater operational reliability. Whoever is familiar with Microsoft Windows can also operate the WinCC Explorer, the central switching point of WinCC. In combination with other SIMATIC components, the system is also equipped with auxiliary functions such as process diagnostics and maintenance. All SIMATIC engineering tools work together in the configuration of the functions. SIMATIC WinCC offers a complete basic functionality for process visualization and operation. To this end WinCC has a number of editors and interfaces that can be used to individually configure this functionality according to the respective application. Expansions of a WinCC station for control tasks are also possible with minimal engineering effort. WinCC editors Task or configurable runtime functionality WinCC Explorer Central project management for the quick access to all project data and central settings WinCC Graphics Designer Graphics system for user-defined visualization and operation via pixelgraphic objects WinCC Alarm Logging Signaling system for detecting and archiving events with display and control options according to DIN 19235; freely selectable message classes, message display and logging WinCC Tag Logging Process archiving for the acquisition, compression and storage of measured values, e.g., presentation in trend and table format as well as further processing WinCC Report Designer Reporting and logging system for time and event-controlled documentation of messages, operator inputs and current process data in the form of user reports or project documentation in an arbitrary layout WinCC User Administrator Tool for user-friendly administration of users and authorizations WinCC Global Script Processing functions with limitless functionality by means of the use of VBScript and ANSI-C V6: 128, 256, 1024, 8192, 65536 PowerTags 4/90 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 HMI Software SCADA system SIMATIC WinCC SIMATIC WinCC Integration in automation solutions ■ Function (continued) WinCC is an open process visualization system and provides the option to connect the most diverse control systems. Interfaces Task or configurable runtime functionality Approved communication software Only communication software with the listed product versions (or higher) should be used. Corresponding SIMATIC NET upgrades are available for upgrading older versions. Communication channels For communication with subordinate controls (SIMATIC protocols, PROFIBUS DP, PROFIBUS FMS, DDE and OPC server included in the scope of delivery) Standard interfaces For the open integration of other Windows applications via WinCC, WinCC-OLE-DB, ActiveX, OLE, DDE, OPC, etc.) For the number of controls connectable via Industrial Ethernet CP 1613, the following applies to a message frame length of 512 bytes: Programming ports For the individual access to data and functions of WinCC and for the integration in user programs with VBA, VB Script, C-API (ODK), C-Script (ANSI-C) Type of connection Number of nodes SIMATIC S5 Ethernet Layer 4 + TCP/IP Up to 60 SIMATIC S7 Protocol Suite Up to 64 SIMATIC 505 Ethernet Layer 4 + TCP/IP Up to 60 ■ Integration Integration in company-wide solutions (IT and business integration) WinCC is strictly based on Microsoft technology, which provides the greatest possible compatibility and integration ability. ActiveX and .net 1) controls support technology-specific and industry-specific expansions. Cross-manufacturer communication is also a simple exercise. The reason: WinCC can be used as an OPC client and server, and in addition to access to current process values, it also supports standards such as OPC HDA (Historical Data Access), OPC Alarm & Events, and OPC XML Data Access. Just as important: Visual Basic for Applications (VBA) for userspecific expansions of the WinCC Graphics Designer and Visual Basic Scripting (VBS) as an easy-to-learn, open runtime language. If desired, professional application developers can also use ANSI-C. And access to the API programming interfaces is really simple with the Open Development Kit ODK. WinCC integrates a powerful and scalable historian function based on Microsoft SQL Server 2005 into the basic system. As a result, users have every possibility: from high-performance archiving of current process data, to long-term archiving with high data compression, through to a central information hub in the form of a company-wide process historian. With the help of the Central Archive Server option, this can be set up within the framework of a WinCC solution. Versatile clients and tools for evaluation, the open interfaces, and special options (Connectivity Pack, Connectivity Station, IndustrialDataBridge) provide the basis for effective IT and business integration. If external networks are accessed, suitable protective measures (incl. IT security measures, such as network segmentation) should be taken in order to ensure safe operation of the system. Number of connectable controls Via PROFIBUS, a maximum of 8 controls can be connected with CP 5611, and a maximum of 44 controls with CP 5613. With approx. 10 or more controls, the usage of Industrial Ethernet is recommended. Mixed operation with different controls With their multi-protocol stack, the CP 1613 and CP 5613 communication processors allow parallel operation of two protocols, such as for the mixed operation of different controls, via a bus cable. WinCC supports the operation of two similar interface boards only in connection with the channels SIMATIC S5 Ethernet Layer 4 (2 x CP 1613), SIMATIC S7 Protocol Suite (2 x CP 1613, 2 x CP 5613) as well as PROFIBUS DP (4 x CP 5613; each CP 5613 max. 122 slaves). In addition to communication over industrial Ethernet CP 1613 or PROFIBUS CP 5613, one CP 5611 can be used in each case for communication with SIMATIC S7 via MPI. Client-server communication Communication between the clients and the server is via TCP/IP protocol. Setting up a separate PC LAN is recommended. For small projects with a correspondingly low incidence of message frames, SIMATIC NET Industrial Ethernet communication can be used for both process communication (WinCC/Server ↔ PLC) and PC-PC communication (WinCC/client ↔ WinCC/server). Channel DLL PROFIBUS DP In accordance with the PROFIBUS standard, DP/slaves are always permanently assigned to a DP master; i.e. a second WinCC station (DP/master) cannot access the same controls (DP/slave). This means that redundant operation of two WinCC stations is not possible using the PROFIBUS DP connection. You can find more information on the topic of Industrial Security on the Internet at: http://www.siemens.com/industrialsecurity 1) Only supported in WinCC V7.0 or higher Siemens ST 80 / ST PC · 2013 4/91 4 © Siemens AG 2013 HMI Software SCADA system SIMATIC WinCC SIMATIC WinCC ■ Integration (continued) Connection to controls from other manufacturers: OPC (OLE for Process Control) is recommended for the connection of controls from other manufacturers. Current notes and information about OPC servers from various suppliers can be found at: http://www.opcfoundation.org WinCC supports the standards: • OPC Data Access 2.05a • OPC Data Access 3.00 • OPC XML Data Access 1.00 (Connectivity Pack / Connectivity Station) • OPC HDA 1.20 (Connectivity Pack / Connectivity Station) • OPC A&E 1.10 (Connectivity Pack / Connectivity Station) • OPC UA Client Data Access • OPC UA Server Data Access, HDA (Connectivity Pack / Connectivity Station) 4 Connection overview Protocol Description SIMATIC S7 SIMATIC S7 Protocol Suite Channel DLL for S7 functions via MPI, PROFIBUS or Ethernet Layer 4 + TCP/IP SIMATIC S5 SIMATIC S5 Ethernet Layer 4 Channel DLL for S5 Layer 4 communication + TCP/IP SIMATIC S5 Programmer Port AS511 Channel DLL and driver for serial communication with S5 using AS511 protocol to programmers port SIMATIC S5 Serial 3964R Channel DLL and driver for serial communication with S5 using RK512 protocol SIMATIC S5 PROFIBUS-FDL Channel DLL for S5-FDL SIMATIC 505 SIMATIC 505 Serial Channel DLL and driver for serial communication with 505 using NITP/ TBP protocol to SIMATIC 535/545/ 555/565/575 SIMATIC 505 Ethernet Layer 4 Channel DLL for 505 Layer 4 communication SIMATIC 505 TCP/IP Channel DLL for 505 TCP/IP communication SIMATIC S7-1200, S7-1500 (WinCC 7.2 or higher) SIMATIC S7-1200, S7-1500 Channel 1) Channel DLL for S7-1200 and S7-1500 communication Controllers from other manufacturers (from WinCC V7.0 SP3) Allen Bradley Ethernet IP Channel DLL and drivers for communication with Allen Bradley controllers via Ethernet TCP/IP using Ethernet IP protocol Modbus TCP/IP Channel DLL and drivers for communication with Modicon controllers via Ethernet TCP/IP using Modbus TCP/IP protocol Mitsubishi MC TCP/IP Channel DLL and drivers for communication with Mitsubishi controllers via Ethernet TCP/IP using Mitsubishi MC TCP/IP protocol Cross-manufacturer 4/92 Siemens ST 80 / ST PC · 2013 OPC client 1) 2) for DA, XML DA Channel DLL for OPC communication, WinCC can acquire data from OPC server applications. OPC server for DA, XML DA, A&E, HDA Server applications for OPC communication; WinCC provides process data to OPC clients OPC UA server for DA, HDA Server applications for OPC UA communication PROFIBUS FMS Channel DLL for PROFIBUS FMS PROFIBUS DP Channel DLL for PROFIBUS DP SIMOTION Channel DLL for SIMOTION 1) WinCC version V7.2 or higher supports communication with S7-1200 / S7-1500 CPU. Restrictions: No symbolic address, type safe structure support (absolute address only) No CPU alarming support 2) Application note: Parallel usage of the OPC client channel allows, for example, connection to an SNMP-OPC server for visualization of the data contained there. The SNMP OPC server enables monitoring of any network components (such as switches) that support the SNMP protocol. You can find more information under SIMATIC NET Communications Systems/SNMP OPC Server. 3) WinCC V7.0 SP3 and later supports OPC UA (United Architecture) Client for DA. © Siemens AG 2013 HMI Software SCADA system SIMATIC WinCC SIMATIC WinCC ■ Integration (continued) Communications components for PG/PC for SIMATIC (for WinCC V7.2) Industrial Ethernet SIMATIC S5 Ethernet Layer 4 SIMATIC S5 TCP/IP • • SIMATIC S7 Protocol Suite SIMATIC 505 Ethernet Layer 4 SIMATIC 505 TCP/IP 1) Order No. WinCC – channel DLL SIMATIC S5 Ethernet Layer 4 Channel DLL for S5 Layer 4 communication + TCP/IP Included in the basic package Included in the basic package • SIMATIC S7 Protocol Suite Channel DLL for S7 functions Included in the basic package • SIMATIC 505 Ethernet Layer 4 Channel DLL for 505 Layer 4 communication SIMATIC 505 TCP/IP 1) Channel DLL for 505 TCP/IP communication • Included in the basic package • 6GK1161-2AA00 Communication components for extension of the OS/OP CP 1612 PCI card for connecting a PG/PC to Industrial Ethernet (SOFTNET-S7 or SOFTNET-S7 Lean communication software must be ordered separately) • • SOFTNET-S7 Communication software for S7 functions (max. 64 connections) • Version 8.1 2)3) for Windows 7 (32/64-bit) and Server 2008 R2 (64-bit) • Edition 2008 SP2 (V7.1) 2) for Windows XP/2003 Server/(32-bit) 2008 Server • • SOFTNET-S7 Lean Communication software for S7 functions (max. 8 connections) • Version 8.2 SP1 2) 4) for Windows 7 (32/64-bit) and Server 2008 R2 (64-bit) • Edition 2008 SP2 (V7.1) 2) 4) for Windows XP/2003 Server / (32-bit) 2008 Server • 6GK1704-1CW81-3AA0 6GK1704-1CW71-3AA0 • 6GK1704-1LW08-2AA0 6GK1704-1LW71-3AA0 CP 1613 PCI card for connecting a PG/PC to Industrial Ethernet (S7-1613 communication software must be ordered separately) • • • • • 6GK1161-3AA00 CP 1613 A2 PCI card (32-bit) for connecting a PG/PC to Industrial Ethernet (S7-1613 communication software required) • • • • • 6GK1161-3AA01 CP 1623 PCI Express X1 card (32-bit) for connecting a PG/PC to Industrial Ethernet (S7-1613 communication software required) • • • • • 6GK1162-3AA00 S7-1613 Communication software for S7 functions and S5/505 Layer 4 communication with TCP/IP • Version 8.2 SP1 2)3) for Windows 7 (32/64-bit) and Server 2008 R2 (64-bit) • Edition 2008 SP2 (V7.1) 2) for Windows XP/2003 Server / (32-bit) 2008 Server • • • • 6GK1716-1CB08-2AA0 6GK1 716-1CB71-3AA0 • System interface possible 1) Via any interface board with NDIS 3.0 interface; no separate communication software required 2) See ordering data for SIMATIC NET upgrade packages 3) SIMATIC NET Version 8.2 SP1 4) SOFTNET-S7 Lean included in scope of supply of WinCC V7.2 Siemens ST 80 / ST PC · 2013 4/93 4 © Siemens AG 2013 HMI Software SCADA system SIMATIC WinCC SIMATIC WinCC ■ Integration (continued) Communication components for PG/PC for SIMATIC (for WinCC V7.0) PROFIBUS SIMATIC S5 PROFIBUS FDL SIMATIC S7 Protocol Suite PROFIBUS DP PROFIBUS FMS Order No. WinCC – channel DLL SIMATIC S5 PROFIBUS FDL Channel DLL for S5-FDL Included in the basic package • SIMATIC S7 Protocol Suite Channel DLL for S7 functions Included in the basic package • Included in the basic package • PROFIBUS DP Channel DLL for PROFIBUS DP • PROFIBUS FMS Channel DLL for PROFIBUS FMS Included in the basic package Communication components for extension of the OS/OP 4 CP 5611 A2 PCI card (32-bit) for connecting a PG/PC to PROFIBUS or MPI (communication software included in WinCC basic package) • 6GK1561-1AA01 CP 5612 2) PCI card (32-bit) for connecting a PG/PC to PROFIBUS (communication software included in WinCC basic package) • 6GK1561-2AA00 CP 5621 PCI Express X1 card (32-bit) for connecting a PG/PC to PROFIBUS or MPI (communication software included in WinCC basic package) • 6GK1562-1AA00 CP 5622 2) PCI Express X1 card (32-bit) for connecting a PG/PC to PROFIBUS (communication software included in WinCC basic package) • 6GK1562-2AA00 CP 5711 2) USB adapter for connecting a PG/PC to PROFIBUS or MPI (communication software included in the WinCC basic package) • 6GK1571-1AA00 CP 5512 PCMCIA card (Cardbus 32-bit) for connecting a PG/PC to PROFIBUS or MPI (communication software included in WinCC basic package) • 6GK1551-2AA00 • System interface possible 1) See ordering data for SIMATIC NET upgrade package 2) SIMATIC NET Version 8.2 SP1 4/94 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 HMI Software SCADA system SIMATIC WinCC SIMATIC WinCC ■ Integration (continued) Communication components for PG/PC for SIMATIC (for WinCC V7.0) PROFIBUS SIMATIC S5 PROFIBUS FDL SIMATIC S7 Protocol Suite PROFIBUS DP PROFIBUS FMS Order No. Communication components for extension of the OS/OP (continued) CP 5613 A2 PCI card (32-bit) for connecting a PC to PROFIBUS (S7-5613, DP-5613 or FMS-5613 communication software required) • • • • 6GK1561-3AA01 CP 5614 A2 PCI card (32-bit) for connecting a PC to PROFIBUS (communication software must be ordered separately) • • • • 6GK1561-4AA01 CP 5623 PCI Express X1 card (32-bit) for connecting a PG/PC to PROFIBUS or MPI (S7-5613 communication software or DP-5613 or FMS-5613 required) • • • • 6GK1562-3AA00 S7-5613 communication software for S7 functions + FDL • Version 8.1 1) 2) for Windows 7 (32/64-bit) and Server 2008 R2 (64-bit) • Edition 2008 SP2 (V7.1) 1) 2) for Windows XP/2003 Server / (32-bit) 2008 Server • • DP-5613 Communication software for DP master + FDL • Version 8.1 1) 2) for Windows 7 (32/64-bit) and Server 2008 R2 (64-bit) • Edition 2008 SP2 (V7.1) 1) 2) for Windows XP/2003 Server / (32-bit) 2008 Server • FMS-5613 Communication software for PROFIBUS-FMS + FDL • Edition 2008 SP2 (V7.1) 1) 2) for Windows XP/2003 Server / (32-bit) 2008 Server • 6GK1713-5CB81-3AA0 6GK1713-5CB71-3AA0 4 • 6GK1713-5DB81-3AA0 6GK1713-5DB71-3AA0 • 6GK1713-5FB71-3AA0 • System interface possible 1) See ordering data for SIMATIC NET upgrade package 2) SIMATIC NET Version 8.2 SP1 Siemens ST 80 / ST PC · 2013 4/95 © Siemens AG 2013 HMI Software SCADA system SIMATIC WinCC SIMATIC WinCC ■ Integration (continued) Communication examples SIMATIC NET PROFIBUS (S7 functions) Standard PC with WinCC e.g. RC 64 k or RT 64 k - CP 5613 A2 - CP 5623 - S7-5613 (communication software) PROFIBUS - CP 443-5 Extended (DP/M, S7, S/R) - CP 443-5 Basis (FMS, S7, S/R) - NCM S7 PROFIBUS manual (SIMATIC NET CD or Internet Download) 4 SIMATIC S7-300 - CP 342-5 (DP, S7, S/R) - CP 343-5 (FMS, S7, S/R) - NCM S7 PROFIBUS manual (SIMATIC NET CD or Internet Download) G_ST80_XX_00010 SIMATIC S7-400 WinCC single-user system: PROFIBUS with S7 communication SIMATIC NET Industrial Ethernet (S7 functions) Standard PC with WinCC e.g. RC 64 k or RT 64 k - CP 1613 A2 6GK1 161-3AA01 - CP 1623 6GK1 162-3AA00 - S7-1613 (communication software) 6GK1 716-1CB80-3AA0 Industrial Ethernet - CP 443-1 (S7, S/R) ISO + TCP 6GK7 443-1EX20-0XE0 - CP 443-1 Advanced (S7, S/R, HTTP) 6GK7 443-1GX20-0XE0 - NCM S7 PROFIBUS manual (SIMATIC NET CD or Internet Download) WinCC single-user system: Industrial Ethernet with S7 communication 4/96 Siemens ST 80 / ST PC · 2013 SIMATIC S7-300 - CP 343-1 (S7, S/R) ISO + TCP 6GK7 343-1EX30-0XE0 - CP 343-1 Advanced (S7, S/R, HTTP) 6GK7 343-1GX30-0XE0 - NCM S7 PROFIBUS manual (SIMATIC NET CD or Internet Download) G_ST80_XX_00011 SIMATIC S7-400 © Siemens AG 2013 HMI Software SCADA system SIMATIC WinCC SIMATIC WinCC ■ Integration (continued) SIMATIC NET PROFIBUS-FMS - CP 5613 A2 6GK1 561-3AA00 - CP 5623 6GK1 562-3AA00 - FMS-5613 (communication software) 6GK1 713-5FB80-3AA0 Standard PC with WinCC e.g. RC 64 k or RT 64 k + FMS channel DLL PROFIBUS FMS SIMATIC S7-400 SIMATIC S7-300 - CP 443-5 Basic - CP 343-5 (FMS, S7, S/R) (FMS, S7, S/R) 6GK7 343-5FA01-0XE0 6GK7 443-5FX02-0XE0 SIMATIC S5115/135/155U - COM 5431 FMS/DP 6GK1 745-1AD00-0EA0 G_ST80_XX_00012 - CP 5431 FMS/DP 6GK1 543-1AA01 WinCC single-user system: PROFIBUS FMS without operator controls: 32 clients + 3 web clients or 50 web clients + 1 client Standard PC with WinCC e.g. RC 64 k or RT 64 k + TCP/IP interface module Client up to 4 clients with operator controls Client TERMINAL BUS TCP/IP Server PROCESS BUS (Industrial Ethernet/PROFIBUS) SIMATIC S7-300 This allows you to set up the following application examples - WinCC single-user system: SIMATIC NET PROFIBUS with S7 functions - WinCC single-user system: SIMATIC NET Industrial Ethernet with S7 functions - WinCC single-user system: SIMATIC NET PROFIBUS-FMS G_ST80_XX_00013 SIMATIC S7-400 WinCC multi-user system with operable server Siemens ST 80 / ST PC · 2013 4/97 4 © Siemens AG 2013 HMI Software SCADA system SIMATIC WinCC SIMATIC WinCC ■ Integration (continued) Higher-level visualisation system - OPC server functionality (included in WinCC basic package) - TCP-IP interface board required OPC Client Industrial Ethernet - OPC Server functionality (OPC Server option for WinCC flexible required) On-site visualization OPC Server OPC Server - OPC Server functionality (included in WinCC basic package) - TCP-IP Interface board required OPC Client OPC Server PROFIBUS SIMATIC S7-300 SIMATIC S7-400 third-party PLCs 4 OPC link 4/98 Siemens ST 80 / ST PC · 2013 - OPC Client functionality (included in WinCC basic package) - OPC Server required for interfacing with third-party PLCs G_ST80_XX_00015 - integrated PROFIBUS interface © Siemens AG 2013 HMI Software SCADA system SIMATIC WinCC SIMATIC WinCC ■ Technical specifications Type SIMATIC WinCC V7.2 and V7.0 SP3 SIMATIC WinCC V6.2 SP3 Operating system • Windows 7 (32 bit / 64 bit) Ultimate, Professional and Enterprise • Windows XP Professional SP3, • Windows XP Professional SP3 • Windows Server 2003 SP2, • Windows 2003 Server SP2 and Windows 2003 Server R2 SP2 • Windows Server 2003 R2 SP2 • Windows 2000 Professional SP4, • Windows Server 2008 SP2 (32 bit) Standard • Windows Server 2008 R2 SP1 (64 bit) Standard PC hardware requirements Processor type 1) • Minimum Single-user station/server: Pentium 4, 2.5 GHz 2) Single-user station/server: Pentium III, 1 GHz Central Archive Server (V7.0 SP3): Pentium 4, 2.5 GHz Central Archive Server: Pentium 4, 2 GHz Client: Pentium 3, 1 GHz 2) Client: Pentium III, 600 MHz WebClient/DataMonitor Client: Pentium III, 600 MHz 2) Single-user station/server: Pentium 4 or Dual Core, 3 GHz 2) Single-user station/server: Pentium 4, 2 GHz Central Archive Server (V7.0 SP3): Pentium 4 or Dual Core, 3 GHz Central Archive Server: Pentium 4, 2.5 GHz Client: Pentium 4, 2 GHz 2) Client: Pentium III, 1 GHz WebClient/DataMonitor Client: Pentium III, 1 GHz WebClient/DataMonitor Client: Pentium III, 1 GHz Single-user station/server: 4 GB 2) Single-user station: 512 MB, server: 1 GB Central Archive Server: 4 GB Central Archive Server: 1 GB Client: 1 GB 2) Client: 512 MB WebClient/DataMonitor Client: 512 MB 2) Single-user station/server: 8 GB 2) WebClient/DataMonitor Client: 256 MB Single-user station: >= 1 GB, server: >1 GB Central Archive Server: ≥ 4 GB Central Archive Server: ≥ 2 GB Client: 2 GB 2) Client: 512 MB WebClient/DataMonitor Client: 1 GB 2) WebClient/DataMonitor Client: 512 MB Graphics card • Minimum • Recommended 16 MB, 800 x 600 2) 32 MB, 1280 x 1024 2) 16 MB, 800 x 600 32 MB, 1280 x 1024 Hard disk • Minimum Single-user station/server: 80 GB Single-user station/server: 20 GB Client: 20 GB Client: 5 GB Central Archive Server: 40 GB Central Archive Server: 40 GB WebClient/DataMonitor Client: 5 GB Single-user station/server: 160 GB WebClient/DataMonitor Client: 5 GB Single-user station/server: 80 GB Client: 40 GB Client: 20 GB Central Archive Server: 2 x 80 GB Central Archive Server: 2 x 80 GB WebClient/DataMonitor Client: 10 GB WebClient/DataMonitor Client: 10 GB Server: >1.5 GB Server: 1.5 GB Client: 1.5 GB Server: >10 GB Client: 1 GB Server: >10 GB Client: >1.5 GB Client: >1.5 GB for software installation for software installation • Recommended RAM • Minimum • Recommended • Recommended • Hard disk (available memory for installation) - Minimum - Recommended CD-ROM/DVD-ROM/disk drive/ USB port 1) An AMD system with comparable performance can also be used 2) Hardware requirements when using Microsoft XP Professional Siemens ST 80 / ST PC · 2013 4 4/99 © Siemens AG 2013 HMI Software SCADA system SIMATIC WinCC SIMATIC WinCC ■ Technical specifications (continued) Type SIMATIC WinCC Functionality/ quantity structure Number of messages • Message text (number of characters) • Message archive • Process values per message • Constant load of messages, max. • Message burst, max. Archives • Archive data points • Archive types • Data storage format • Measured values per second, max. User archive • Archives and views • Product consisting of data record and column per user archive • Fields per user archive 4 Graphics system • Number of screens • Number of objects per screen • Number of controllable fields per screen 4/100 150,000 10 x 256 > 500,000 messages 1) 10 Central Archive Server: 100/sec Server/single-user station: 10/s Server/single-user station: 2,000/10 s every 5 min Max. 120,000 per server 2) Short-term archive with and without long-term archiving Microsoft SQL Server 2005 Server/single-user station: 5,000/s 500 each 320,000 500 System-limited 1) System-limited 1) System-limited 1) Siemens ST 80 / ST PC · 2013 Type SIMATIC WinCC PowerTags 256 K 3) Trends • Trend views per image • Trends per trend view 25 80 User administration • User groups • Number of users • Authorization groups 128 128 999 Configuration languages Protocols • Message sequence reports (simultaneously) • Message archive reports (simultaneously) • User reports • Report lines per group • Variables per report Multi-user system • Server • Clients for server with operator station • Clients for server without operator station 5 European (Eng., Fr., Ger., It., Sp.), 4 Asian (simpl.+trad. Chi/Kor/Jpn) 4) 1 per server/single-user station 3 System-limited 1) 66 300 5) 18 4 32 clients + 3 WebClients or 50 WebClients + 1 client 1) Dependent on the available storage space 2) Dependent on the number of licensed archive variables 3) Dependent on number of licensed PowerTags 4) Asian versions for Version 7 SP1 or higher 5) The number of variables per report is dependent on process communication performance © Siemens AG 2013 HMI Software SCADA system SIMATIC WinCC SIMATIC WinCC ■ Ordering data Order No. SIMATIC WinCC system software V7.2 For upgrading from: Runtime packages on DVD Language/script versions: De, En, Fr, It, Es; with license for • WinCC RT Client • 128 PowerTags (RT 128) • 512 PowerTags (RT 512) • 2048 PowerTags (RT 2048) • 8192 PowerTags (RT 8192) • 65536 PowerTags (RT 65536) • 102400 PowerTags (RT 102400) • 153600 PowerTags (RT 153600) • 262144 PowerTags (RT 262144) 6AV6381-2CA07-2AX0 6AV6381-2BC07-2AX0 6AV6381-2BD07-2AX0 6AV6381-2BE07-2AX0 6AV6381-2BH07-2AX0 6AV6381-2BF07-2AX0 6AV6381-2BJ07-2AX0 6AV6381-2BK07-2AX0 6AV6381-2BL07-2AX0 Including 512 archive tags each Complete packages on DVD Language versions: De, En, Fr, It, Es; with license for • WinCC RC Client • 128 PowerTags (RC 128) • 512 PowerTags (RC 512) • 2048 PowerTags (RC 2048) • 8192 PowerTags (RC 8192) • 65536 PowerTags (RC 65536) • 102400 PowerTags (RC 102400) • 153600 PowerTags (RC 153600) • 262144 PowerTags (RC 262144) 6AV6381-2CB07-2AX0 6AV6381-2BM07-2AX0 6AV6381-2BN07-2AX0 6AV6381-2BP07-2AX0 6AV6381-2BS07-2AX0 6AV6381-2BQ07-2AX0 6AV6381-2BT07-2AX0 6AV6381-2BU07-2AX0 6AV6381-2BV07-2AX0 SIMATIC WinCC system software V7.2 ASIA Runtime packages on DVD Language/script versions: En, Chs, Cht, Kor, Jpn; with license for • WinCC RT Client • 128 PowerTags (RT 128) • 512 PowerTags (RT 512) • 2048 PowerTags (RT 2048) • 8192 PowerTags (RT 8192) • 65536 PowerTags (RT 65536) • 102400 PowerTags (RT 102400) • 153600 PowerTags (RT 153600) • 262144 PowerTags (RT 262144) Order No. SIMATIC WinCC V7.2 Powerpacks 6AV6381-2CA07-2AV0 6AV6381-2BC07-2AV0 6AV6381-2BD07-2AV0 6AV6381-2BE07-2AV0 6AV6381-2BH07-2AV0 6AV6381-2BF07-2AV0 6AV6381-2BJ07-2AV0 6AV6381-2BK07-2AV0 6AV6381-2BL07-2AV0 Including 512 archive tags each Complete packages on DVD Language versions: EN, CHS, CHT, KOR, JPN; with license for • WinCC RC Client • 128 PowerTags (RC 128) • 512 PowerTags (RC 512) • 2048 PowerTags (RC 2048) • 8192 PowerTags (RC 8192) • 65536 PowerTags (RC 65536) • 102400 PowerTags (RC 102400) • 153600 PowerTags (RC 153600) • 262144 PowerTags (RC 262144) 6AV6381-2CB07-2AV0 6AV6381-2BM07-2AV0 6AV6381-2BN07-2AV0 6AV6381-2BP07-2AV0 6AV6381-2BS07-2AV0 6AV6381-2BQ07-2AV0 6AV6381-2BT07-2AV0 6AV6381-2BU07-2AV0 6AV6381-2BV07-2AV0 Clients • RT Client ASIA • RT Client • RC Client ASIA • RC Client 6AV6381-2CA07-2AV0 6AV6381-2CA07-2AX0 6AV6381-2CB07-2AV0 6AV6381-2CB07-2AX0 Runtime packages • 128 to 512 PowerTags • 512 to 2048 PowerTags • 2048 to 8192 PowerTags • 8192 to 65536 PowerTags • 65536 to 102400 PowerTags • 102400 to 153600 PowerTags • 153600 to 262144 PowerTags 6AV6371-2BD07-2AX0 6AV6371-2BG07-2AX0 6AV6371-2BM07-2AX0 6AV6371-2BN07-2AX0 6AV6371-2BP07-2AX0 6AV6371-2BQ07-2AX0 6AV6371-2BR07-2AX0 Complete packages • 128 to 512 PowerTags • 512 to 2048 PowerTags • 2048 to 8192 PowerTags • 8192 to 65536 PowerTags • 65536 to 102400 PowerTags • 102400 to 153600 PowerTags • 153600 to 262144 PowerTags 6AV6371-2BD17-2AX0 6AV6371-2BG17-2AX0 6AV6371-2BM17-2AX0 6AV6371-2BN17-2AX0 6AV6371-2BP17-2AX0 6AV6371-2BQ17-2AX0 6AV6371-2BR17-2AX0 SIMATIC WinCC V7.2 archives • 1500 archives • 5000 archives • 10000 archives • 30000 archives • 80000 archives 6AV6371-1DQ17-2AX0 6AV6371-1DQ17-2BX0 6AV6371-1DQ17-2CX0 6AV6371-1DQ17-2EX0 6AV6371-1DQ17-2GX0 4 SIMATIC WinCC V7.2 archive powerpacks For upgrading archiving from • 1500 to 5000 archive tags • 5000 to 10000 archive tags • 10000 to 30000 archive tags • 30000 to 80000 archive tags 6AV6371-1DQ17-2AB0 6AV6371-1DQ17-2BC0 6AV6371-1DQ17-2CE0 6AV6371-1DQ17-2EG0 SIMATIC WinCC Upgrade/ Software Update Service SIMATIC WinCC V7.2 upgrade 1) For upgrading the RT version • from V6.2 to V7.2 • from V7.0 to V7.2 • from V6.2 ASIA to V7.2 ASIA • from V7.0 ASIA to V7.2 ASIA 6AV6381-2AA07-2AX4 6AV6381-2AA07-2AX3 6AV6381-2AA07-2AV4 6AV6381-2AA07-2AV3 For upgrading the Client RT version • from V6.2 to V7.2 • from V7.0 to V7.2 • from V6.2 ASIA to V7.2 ASIA • from V7.0 ASIA to V7.2 ASIA 6AV6381-2BC07-2AX4 6AV6381-2BC07-2AX3 6AV6381-2BC07-2AV4 6AV6381-2BC07-2AV3 For upgrading the RC version • from V6.2 to V7.2 • from V7.0 to V7.2 • from V6.2 ASIA to V7.2 ASIA • from V7.0 ASIA to V7.2 ASIA 6AV6381-2AB07-2AX4 6AV6381-2AB07-2AX3 6AV6381-2AB07-2AV4 6AV6381-2AB07-2AV3 SIMATIC WinCC Software Update Service (SUS) 2) 3) SIMATIC WinCC V7 Update Software Update Service for WinCC basic software and options: • 1 license • 3 licenses • 10 licenses 6AV6381-1AA00-0AX5 6AV6381-1AA00-0BX5 6AV6381-1AA00-0CX5 1) According to licensing provisions, 1 upgrade package must be ordered for each WinCC station 2) The Software Update Service is valid for 1 year. The contract is automatically extended by 1 more year unless canceled 3 months prior to expiration. According to licensing provisions, 1 Software Update Service must be ordered for each WinCC station. 3) Requires the current software version Siemens ST 80 / ST PC · 2013 4/101 © Siemens AG 2013 HMI Software SCADA system SIMATIC WinCC SIMATIC WinCC ■ Ordering data Order No. For upgrading from: Runtime packages on CD-ROM Language/script versions: DE/EN/FR/IT/ES; with license for • 128 PowerTags (RT 128) • 256 PowerTags (RT 256) • 1024 PowerTags (RT 1024) • 8192 PowerTags (RT 8192) • 65536 PowerTags (RT 65536) • 102400 PowerTags (RT 102400) • 153600 PowerTags (RT 153600) • 262144 PowerTags (RT 262144) 6AV6381-1BC06-2AX0 6AV6381-1BD06-2AX0 6AV6381-1BE06-2AX0 6AV6381-1BH06-2AX0 6AV6381-1BF06-2AX0 6AV6381-1BJ06-2AX0 6AV6381-1BK06-2AX0 6AV6381-1BL06-2AX0 Including 512 archive tags each Complete packages on CD-ROM 4 Language versions: DE/EN/FR/IT/ES; with license for • 128 PowerTags (RC 128) • 256 PowerTags (RC 256) • 1024 PowerTags (RC 1024) • 8192 PowerTags (RC 8192) • 65536 PowerTags (RC 65536) • 102400 PowerTags (RC 102400) • 153600 PowerTags (RC 153600) • 262144 PowerTags (RC 262144) 6AV6381-1BM06-2AX0 6AV6381-1BN06-2AX0 6AV6381-1BP06-2AX0 6AV6381-1BS06-2AX0 6AV6381-1BQ06-2AX0 6AV6381-1BT06-2AX0 6AV6381-1BU06-2AX0 6AV6381-1BV06-2AX0 Including 512 archive tags each SIMATIC WinCC system software V6.2 SP3 ASIA Runtime packages on CD-ROM Language versions: English/simplified and traditional Chinese/Korean/ Taiwanese/Japanese; with license for • 128 PowerTags (RT 128) • 256 PowerTags (RT 256) • 1024 PowerTags (RT 1024) • 8192 PowerTags (RT 8192) • 65536 PowerTags (RT 65536) Order No. SIMATIC WinCC V6.2 Powerpacks SIMATIC WinCC system software V6.2 SP3 Runtime packages • 128 to 256 PowerTags • 128 to 1024 PowerTags • 128 to 8192 PowerTags • 128 to 65536 PowerTags • 256 to 1024 PowerTags • 256 to 8192 PowerTags • 256 to 65536 PowerTags • 1024 to 8192 PowerTags • 1024 to 65536 PowerTags • 8192 to 65536 PowerTags 6AV6371-1BD06-2AX0 6AV6371-1BE06-2AX0 6AV6371-1BK06-2AX0 6AV6371-1BF06-2AX0 6AV6371-1BG06-2AX0 6AV6371-1BL06-2AX0 6AV6371-1BH06-2AX0 6AV6371-1BM06-2AX0 6AV6371-1BJ06-2AX0 6AV6371-1BN06-2AX0 Complete packages • 128 to 256 PowerTags • 128 to 1024 PowerTags • 128 to 8192 PowerTags • 128 to 65536 PowerTags • 256 to 1024 PowerTags • 256 to 8192 PowerTags • 256 to 65536 PowerTags • 1024 to 8192 PowerTags • 1024 to 65536 PowerTags • 8192 to 65536 PowerTags 6AV6371-1BD16-2AX0 6AV6371-1BE16-2AX0 6AV6371-1BK16-2AX0 6AV6371-1BF16-2AX0 6AV6371-1BG16-2AX0 6AV6371-1BL16-2AX0 6AV6371-1BH16-2AX0 6AV6371-1BM16-2AX0 6AV6371-1BJ16-2AX0 6AV6371-1BN16-2AX0 SIMATIC WinCC V6.2 Archive • 1500 archives • 5000 archives • 10000 archives • 30000 archives • 80000 archives • 120000 archives 6AV6371-1DQ16-2AX0 6AV6371-1DQ16-2BX0 6AV6371-1DQ16-2CX0 6AV6371-1DQ16-2EX0 6AV6371-1DQ16-2GX0 6AV6371-1DQ16-2JX0 SIMATIC WinCC V6.2 Archive Powerpacks 6AV6381-1BC06-2AV0 6AV6381-1BD06-2AV0 6AV6381-1BE06-2AV0 6AV6381-1BH06-2AV0 6AV6381-1BF06-2AV0 Including 512 archive tags each For upgrading archiving from • 1500 to 5000 archive tags • 5000 to 10000 archive tags • 10000 to 30000 archive tags • 30000 to 80000 archive tags • 80000 to 120000 archive tags Complete packages on CD-ROM SIMATIC WinCC V6.2 upgrade 1) Language versions: English/simplified and traditional Chinese/Korean/ Taiwanese, Japanese; with license for • 128 PowerTags (RC 128) • 256 PowerTags (RC 256) • 1024 PowerTags (RC 1024) • 8192 PowerTags (RC 8192) • 65536 PowerTags (RC 65536) 6AV6381-1BM06-2AV0 6AV6381-1BN06-2AV0 6AV6381-1BP06-2AV0 6AV6381-1BS06-2AV0 6AV6381-1BQ06-2AV0 Including 512 archive tags each For upgrading the RT version • from V5.x to V6.2 SP3 • from V6.x to V6.2 SP3 • from V5.x ASIA to V6.2 SP3 ASIA • from V6.x ASIA to V6.2 SP3 ASIA 6AV6381-1AA06-2AX4 6AV6381-1AA06-2AX3 6AV6381-1AA06-2AV4 6AV6381-1AA06-2AV3 For upgrading the RC version • from V5.x to V6.2 SP3 • from V6.x to V6.2 SP3 • from V5.x ASIA to V6.2 SP3 ASIA • from V6.x ASIA to V6.2 SP3 ASIA 6AV6381-1AB06-2AX4 6AV6381-1AB06-2AX3 6AV6381-1AB06-2AV4 6AV6381-1AB06-2AV3 1) 4/102 Siemens ST 80 / ST PC · 2013 6AV6371-1DQ16-2AB0 6AV6371-1DQ16-2BC0 6AV6371-1DQ16-2CE0 6AV6371-1DQ16-2EG0 6AV6371-1DQ16-2GJ0 According to licensing provisions, 1 upgrade package must be ordered for each WinCC station. © Siemens AG 2013 HMI Software SCADA system SIMATIC WinCC SIMATIC WinCC ■ Ordering data Order No. SIMATIC WinCC V7.2 communication Communication via Industrial Ethernet CP 1612 A2 PCI card (32-bit) for connection of a programming device or PC to Industrial Ethernet (10/100/1000 Mbps) with RJ45 connection via SOFTNET S7 and SOFTNET PG SOFTNET-IE S7 Version 8.2 SP1 1) Software for S7-compatible and S5-compatible communication incl. OPC server, PG/OP communication and NCM PC; up to 64 connections; single license for one installation of Runtime software, software and electronic manual on CD-ROM; license key on USB stick; Class A for CP 1612-A2 English/German • Single license for 1 installation • Upgrade package for SIMATIC NET Edition 2006 or higher • Upgrade package for SIMATIC NET V6.0, V6.1, V6.2 and Edition 2005 SOFTNET-IE S7 Lean Version 8.2 SP1 (license included in scope of delivery of WinCC V7.2) Software for S7-compatible and S5-compatible communication incl. OPC server, PG/OP communication and NCM PC; up to 8 connections; single license for one installation of Runtime software, software and electronic manual on CD-ROM; license key on USB stick; Class A for CP 1612-A2 English/German • Single license for 1 installation • Upgrade package for SIMATIC NET Edition 2006 or higher • Upgrade package for SIMATIC NET V6.0, V6.1, V6.2 and Edition 2005 6GK1161-2AA01 Order No. HARDNET-IE S7 V8.2 SP1 1) Software for S7-compatible and S5-compatible communication incl. OPC server, PG/OP communication and NCM PC, single license for one installation of Runtime software, software and electronic manual on CD-ROM, license key on USB stick, Class A for CP 1613-A2, CP 1623, CP 1628; English/German • Single license for 1 installation • Upgrade package for SIMATIC NET Edition 2006 or higher • Upgrade package for SIMATIC NET V6.0, V6.1, V6.2 and Edition 2005 6GK1716-1CB08-2AA0 6GK1716-1CB00-3AE0 6GK1716-1CB00-3AE1 Communication via PROFIBUS 6GK1704-1CW08-2AA0 6GK1704-1CW00-3AE0 6GK1704-1CW00-3AE1 6GK1704-1LW81-3AA0 6GK1704-1LW00-3AE0 6GK1704-1LW00-3AE1 CP 1613 A2 PCI card (32-bit) for connecting a PG/PC to Industrial Ethernet (communications software must be ordered separately) 6GK1161-3AA01 CP 1623 PCI Express X1 card (32-bit) for connection of PG/PC to Industrial Ethernet (communications software must be ordered separately) 6GK1162-3AA00 CP 1628 PCI Express X1 card (32-bit) for connection of PG/PC to Industrial Ethernet (communications software must be ordered separately) 6GK1162-8AA00 1) According to licensing provisions, 1 upgrade package must be ordered for each WinCC station 2) The Software Update Service is valid for 1 year. The contract is automatically extended by 1 more year unless canceled 3 months prior to expiration. According to licensing provisions, 1 Software Update Service must be ordered for each WinCC station. CP 5611 A2 PCI card (32-bit) for connecting a PG/PC to PROFIBUS (communications software included in the WinCC basic package) 6GK1561-1AA01 CP 5612 2) PCI card (32-bit) for connecting a PG/PC to PROFIBUS (communications software included in the WinCC basic package) 6GK1561-2AA00 CP 5621 PCI Express X1 card (32-bit) for connection of PG/PC to PROFIBUS (communications software included in WinCC basic package) 6GK1562-1AA00 CP 5622 2) PCI Express X1 card (32-bit) for connecting a PG/PC to PROFIBUS (communications software included in WinCC basic package) 6GK1562-2AA00 CP 5711 USB adapter for connecting a PG/PC to PROFIBUS or MPI (communications software included in WinCC basic package) 6GK1571-1AA00 CP 5512 PCMCIA card (CARDBUS 32-bit) for the connection of a PG/notebook to PROFIBUS or MPI (communications software included in WinCC basic package) 6GK1551-2AA00 CP 5613 A2 PCI card (32-bit) for connecting a PC to PROFIBUS (communications software must be ordered separately) 6GK1561-3AA01 4 Siemens ST 80 / ST PC · 2013 4/103 © Siemens AG 2013 HMI Software SCADA system SIMATIC WinCC SIMATIC WinCC ■ Ordering data Order No. Communication via PROFIBUS (continued) CP 5614 A2 PCI card (32-bit) for connecting a PC to PROFIBUS (communications software must be ordered separately) 6GK1561-4AA01 CP 5623 PCI Express X1 card (32-bit) for connection of PG/PC to Industrial Ethernet (communications software must be ordered separately) 6GK1562-3AA00 CP 1612 A2 PCI card (32-bit) for connecting a PG/PC to Industrial Ethernet (SOFTNET-S7 must be ordered separately) HARDNET-PB S7 V8.2 SP1 1) Software for S7 communication incl. PG/OP communication, FDL, OPC server, Runtime software, software and electronic manual on CD-ROM, license key on USB stick, Class A for CP 5613-A2, CP 5614-A2, CP 5623 English/German • Single license for 1 installation • Upgrade package for SIMATIC NET Edition 2006 or higher • Upgrade package for SIMATIC NET V6.0, V6.1, V6.2 and Edition 2005 4 Order No. SIMATIC WinCC V6.2 communication Communication via Industrial Ethernet HARDNET-PB DP V8.2 SP1 1) Software for DP protocol incl. PG/OP communication, FDL, DP OPC server, Runtime software, software and electronic manual on CD-ROM, license key on USB stick, Class A, for CP 5613-A2, CP 5614-A2, CP 5623; English/German • Single license for 1 installation • Upgrade package for SIMATIC NET Edition 2006 or higher • Upgrade package for SIMATIC NET V6.0, V6.1, V6.2 and Edition 2005 6GK1713-5CB08-2AA0 6GK1713-5CB00-3AE0 6GK1713-5CB00-3AE1 1) 6GK1713-5DB08-2AA0 6GK1713-5DB00-3AE0 6GK1713-5DB00-3AE1 (license included in scope of delivery of WinCC V6.2) Software for S7-compatible and S5-compatible communication incl. OPC server, PG/OP communication and NCM PC; up to 8 connections; single license for one installation of Runtime software, software and electronic manual on CD-ROM, license key on USB stick, Class A, for CP 1612-A2, English/German • Single license for 1 installation • Upgrade package for SIMATIC NET V6.0, V6.1, V6.2 and Edition 2005 1) CP 1613 A2 PCI card (32-bit) for connecting a PG/PC to Industrial Ethernet (communications software must be ordered separately) 6GK1713-5FB71-3AA0 6GK1713-5FB00-3AE0 6GK1713-5FB00-3AE1 According to licensing provisions, 1 upgrade package must be ordered for each WinCC station 4/104 6GK1704-1CW71-3AA0 6GK1704-1CW00-3AE1 SOFTNET-S7 Lean V7.1 SP6 (Edition 2008+SP6) 1) FMS-5613 V7.1 SP6 (Edition 2008+SP6) 1) Software for FMS protocol incl. PG/OP communication, FDL, OPC server, Runtime software, software and electronic manual on CD-ROM, license key on USB stick, Class A; for CP 5613-A2, CP 5614-A2, CP 5623; English/German • Single license for 1 installation • Upgrade package for SIMATIC NET Edition 2006 or higher • Upgrade package for SIMATIC NET V6.0, V6.1, V6.2 and Edition 2005 SOFTNET-S7 V7.1 SP6 (Edition 2008+SP6) 1) Software for S7-compatible and S5-compatible communication incl. OPC server, PG/OP communication and NCM PC; up to 64 connections; single license for one installation of Runtime software, software and electronic manual on CD-ROM, license key on USB stick, Class A, for CP 1612-A2, English/German • Single license for 1 installation • Upgrade package for SIMATIC NET Edition 2007 Upgrade package for SIMATIC NET V6.0, V6.1, V6.2, and Edition 2005 1) 6GK1161-2AA01 Siemens ST 80 / ST PC · 2013 S7-1613 V7.1 SP6 (Edition 2008+SP6) 1) Software for S7-compatible and S5-compatible communication incl. PG/OP communication, OPC server and NCM PC; single license for one installation of Runtime software, software and electronic manual on CD-ROM, license key on USB stick, Class A for CP 1613-A2; English/German • Single license for 1 installation • Upgrade package for SIMATIC NET V6.0, V6.1, V6.2 and Edition 2005 1) 6GK1704-1LW71-3AA0 6GK1704-1LW00-3AE1 6GK1161-3AA01 6GK1716-1CB71-3AA0 6GK1716-1CB00-3AE1 © Siemens AG 2013 HMI Software SCADA system SIMATIC WinCC SIMATIC WinCC ■ Ordering data Order No. Communication via Industrial Ethernet T7-1613 V7.1 SP6 (Edition 2008+SP6) 1) Software for TF protocol, S5-compatible communication incl. OPC, PG/OP communication (S5/505 layer 4 communication with TCP/IP) single license for one installation of Runtime software, software and electronic manual on CD-ROM, license key on USB stick; Class A for CP 1613-A2 English/German • Single license • Upgrade package for SIMATIC NET Edition 2007 Upgrade package for SIMATIC NET V6.0, V6.1, V6.2, and Edition 2005 1) 6GK1716-1TB71-3AA0 6GK1716-1CB00-3AE1 Communication via PROFIBUS CP 5611 A2 PCI card (32-bit) for connecting a PG/PC to PROFIBUS (communications software included in the WinCC basic package) 6GK1561-1AA01 CP 5621 PCI Express X1 card (32-bit) for connection of PG/PC to PROFIBUS (communications software included in WinCC basic package) 6GK1562-1AA00 CP 5611 MPI Comprising CP 5611 A2 and MPI cable, 5 m 6GK1561-1AM01 CP 5621 MPI Comprising CP 5621 (32-bit) and MPI cable, 5 m 6GK1562-1AM00 CP 5512 PCMCIA card (CARDBUS 32-bit) for the connection of a PG/notebook to PROFIBUS or MPI (communications software included in WinCC basic package) 6GK1551-2AA00 CP 5613 A2 PCI card (32-bit) for connecting a PC to PROFIBUS (communications software must be ordered separately) 6GK1561-3AA01 CP 5614-A2 PCI Card (32-Bit) for connecting a PC to PROFIBUS (communications software must be ordered separately) 6GK1561-4AA01 1) The SIMATIC NET PC software delivered with SIMATIC WinCC V7.2 must always be used. The scope of supply for WinCC V7.2 includes the SIMATIC NET PC software V8.2 SP1 / supported operating systems: 32/64-bit Windows 7 Professional, Ultimate, 64-bit Windows Server 2008 R2 and SIMATIC NET PC Software V7.1 SP6 (Edition 2008+SP6) / supported operating systems: 32-bit Windows XP Professional, Windows Vista Professional, Ultimate, Windows Server 2003, Windows Server 2008 Standard. Only the license is to be used from the scope of supply of the above-listed SIMATIC NET PC software products. The licenses supplied with SIMATIC NET V8.2 SP1 are valid for all older versions up to and including Edition 2006. Order No. S7-5613 V7.1 SP6 (Edition 2008 SP6) Software for S7 communication incl. PG/OP communication, FDL, OPC server; for Windows XP Professional/ 2003 Server/2000 Professional/ Server for CP 5613/CP 5614; English/German • Single license for 1 installation • Upgrade package for SIMATIC NET Edition 2007 Upgrade package for SIMATIC NET V6.0, V6.1, V6.2, and Edition 2005 1) DP-5613 V7.1 SP6 (Edition 2008 + SP6) Software for DP protocol incl. PG/OP communication, FDL, OPC server, Runtime software, software and electronic manual on CD-ROM, license key on USB flash drive, Class A, for 32-bit: Windows XP Professional, Windows 2003 Server, Windows VISTA Ultimate/Business; for CP 5613 A2; English/German • Single license for 1 installation • Upgrade package for SIMATIC NET Edition 2007 Upgrade package for SIMATIC NET V6.0, V6.1, V6.2, and Edition 2005 1) FMS-5613 V7.1 SP6 (Edition 2008 + SP6) Software for FMS protocol incl. PG/OP communication, FDL, FMS-OPC server, for Windows XP Professional/2003 Server/2000 Professional/Server for CP 5613/CP 5614; English/German • Single license for 1 installation • Upgrade package for SIMATIC NET Edition 2007 Upgrade package for SIMATIC NET V6.0, V6.1, V6.2, and Edition 2005 1) 6GK1713-5CB71-3AA0 6GK1713-5CB00-3AE1 6GK1713-5DB71-3AA0 6GK1713-5DB00-3AE1 4 6GK1713-5FB71-3AA0 6GK1713-5FB00-3AE1 Hardware for process control functions DCF-77 receiver for time synchronization • DCF77 (Europe) 2XV9450-1AR14 Note For further information on control technology options see Catalog ST PCS7. Siemens ST 80 / ST PC · 2013 4/105 © Siemens AG 2013 HMI Software SCADA system SIMATIC WinCC SIMATIC WinCC ■ More information WinCC language versions SIMATIC WinCC is also offered in simplified Chinese, traditional Chinese, Korean and Japanese especially for Asian markets. These WinCC versions are intended for machine manufacturers, plant constructors and exporters who supply the regions of China, Taiwan, Korea and Japan. WinCC ASIA includes all familiar WinCC functions and offers in addition the configuration user interface in the respective national language and English. The online help is available in simplified Chinese, traditional Chinese, Korean, Japanese and English. A Chinese, Korean, Japanese or multilingual Windows operating system is required for operation. WinCC ASIA is delivered on a separate DVD which contains all of the above mentioned language versions. The corresponding documentation can be obtained from the national subsidiaries in China, Korea, Taiwan and Japan. The runtime licenses are language-neutral. The English handling program (Automation License Manager – ALM) is executable under the Chinese, Korean and Japanese Windows versions. In order to use the Asian languages in WinCC, an Asia hardware dongle is required. 4 4/106 Siemens ST 80 / ST PC · 2013 Additional information is available on the Internet at: http://www.siemens.com/wincc Separate configurators are available for PC hardware: • SIMATIC IPC547C, SIMATIC Rack PC 547B • SIMATIC IPC647C, SIMATIC Rack PC 647B • SIMATIC IPC847C, SIMATIC Rack PC 847B • SIMATIC IPC427C • SIMATIC IPC627C, SIMATIC Box PC 627B • SIMATIC Box PC 827B • SIMATIC HMI IPC577C, SIMATIC Panel PC 577B • SIMATIC HMI IPC677C, SIMATIC Panel PC 677B © Siemens AG 2013 HMI Software SIMATIC WinCC options SIMATIC WinCC options Options for IT and Business Integration – Plant Intelligence • SIMATIC InformationServer Web-based, integrated reporting from production to management, based on archived data • WinCC/DataMonitor For displaying and evaluating current process states and historical data on office PCs with standard tools • WinCC/DowntimeMonitor For detecting and analyzing downtimes for machines and plants • WinCC/Connectivity Pack Access to WinCC archives via OPC HDA, OPC A&E, OPC XML Server and WinCC OLE-DB /OLE-DB • WinCC/Connectivity Station Gateway to WinCC server data over OPC HDA, OPC A&E, OPC XML server and WinCC OLE-DB /OLE-DB from independent computers • WinCC/IndustrialDataBridge Configurable connection to databases and IT systems ■ Overview C WinCis-SW Bas C, RT R C WinCtion Op C WinCd-on Ad C WinCtion Op C WinCd-on Ad G_ST80_XX_00175 C WinCtion Op C WinCd-on Ad The universal WinCC basic software is the basis for modular expansions. These functional expansions can be obtained in the form of WinCC options and as WinCC Premium add-ons. WinCC options are created by WinCC Development and are Siemens Industry Automation products. You can obtain support from our Advisory Services and via the central hotline. Options for scalable plant configurations • WinCC/Server For configuring a powerful client/server system • WinCC/Web Navigator For controlling and monitoring plants via the Internet, in-house intranet or LAN • WinCC/TeleControl For connecting to outlying stations (remote terminal units = RTUs) via telecontrol protocols in a WinCC SCADA system. • SIMATIC ProcessHistorian Central scalable long-term archive for the whole plant Options for increasing the availability • WinCC/Redundancy For increasing system availability through redundancy • SIMATIC Maintenance Station For system-integrated diagnostics and plant asset management • WinCC/ProAgent For reliable process diagnostics Options for SCADA expansions • WinCC/User Archives For managing data records in user archives • WinCC/Calendar Scheduler Calendar-based planning of events • WinCC/Event Notifier For sending of notifications depending on specific events in the WinCC message system Options for sector-specific expansions • WinCC/ChangeControl - Change and version management - Generation of audit trails for engineering • WinCC/Audit - Change management - Generation of audit trails for engineering and runtime • SIMATIC Logon - Central management of WinCC users, plant-wide (to CFR 21 Part 11) Options for individual system expansions • WinCC/IndustrialX 1) For creating customized WinCC ActiveX objects in a VB development environment • WinCC/ODK (Open Development Kit) For the use of open programming interfaces 1) For WinCC V7.2, the option WinCC/IndustrialX is part of the option WinCC/ODK. ■ More information WinCC options http://www.siemens.com/wincc/options Siemens ST 80 / ST PC · 2013 4/107 4 © Siemens AG 2013 HMI Software SIMATIC WinCC options SIMATIC BATCH for WinCC ■ Overview ■ Benefits • WinCC in connection with the SIMATIC BATCH product range offers a solution for the implementation of batch processes in accordance with ISA S88. • SIMATIC BATCH for WinCC is of particular interest where different PLCs such as S7-400/300, S5 or non-Siemens PLCs are to be used in a BATCH system. • SIMATIC BATCH for WinCC is offered as a bundle that includes the SIMATIC BATCH components as well as the WinCC components. • SIMATIC BATCH for WinCC contains the software for SIMATIC BATCH including options, as well as for SIMATIC WinCC including options. These products are released for any combinations. - SIMATIC BATCH for WinCC includes the licenses SIMATIC BATCH Server (10 units 1)), SIMATIC BATCH CC, and SIMATIC BATCH Recipe. - All other SIMATIC BATCH and SIMATIC WinCC products require the purchase of the relevant license or licenses. 1) Current versions: • SIMATIC BATCH for WinCC V7.1 SP1 (only runs on Windows XP und Windows 2003 Server operating systems) - WinCC V7.0 SP3 - SIMATIC BATCH V7.1 SP1 Configuration S5-135U S7-300/400 SIMATIC BATCH for WinCC 4/108 Siemens ST 80 / ST PC · 2013 SIMATIC BATCH for WinCC has been designed for: • Batch processes in the WinCC environment in accordance with ISA S88 • Users of S7-300, S7-400, S5 or non-Siemens controllers • Users of STEP5/STEP7 SIMATIC BATCH for WinCC ships with the following 3 software components and licenses: • SIMATIC BATCH Server for 10 units • SIMATIC BATCH Recipe system (Floating License) • SIMATIC BATCH CC (Floating License) PROCESS BUS 3rd-party PLCs ■ Application ■ Design SIMATIC BATCH for WinCC BASIC 10 Units G_ST80_XX_00263 4 Units are the number of subsystems that can be operated with this license. • SIMATIC BATCH for WinCC supports the user in the implementation of batch processes in accordance with ISA S88 • Modular architecture with flexible scalability and optimal adaptation to plant size and individual requirements, especially with regard to the use of PLCs such as SIMATIC S7-400/300, SIMATIC S5 and non-Siemens devices • High availability via redundant system configurations provides protection against loss of batch data • Cross-subsystem recipes with significant simplification of recipe management • Hierarchical recipes in accordance with ISA S88.01 for the creation of recipes oriented toward process engineering • Saving, archiving and comprehensive reporting of batch data • Formula support • Validation in accordance with 21 CFR Part 11 is significantly simplified by functions such as Audit Trail (change log), versioning of recipes, recipe operations and formulas, electronic signature and access protection. The following SIMATIC BATCH options can be used to expand or configure a plant or the relevant licenses can be purchased: • SIMATIC BATCH Recipe system (Floating License) • SIMATIC BATCH Planning (Floating License) • SIMATIC BATCH CC (Floating License) • SIMATIC BATCH Library • SIMATIC BATCH Hierarchical Recipe • SIMATIC BATCH Formula • SIMATIC BATCH Powerpacks (20, 40, 100, unlimited) © Siemens AG 2013 HMI Software SIMATIC WinCC options SIMATIC BATCH for WinCC ■ Design (continued) SIMATIC BATCH Separation, Procedures and Formulas offers powerful functions for the following tasks: The following basic products and SIMATIC WinCC options can be used to expand or configure a plant or the relevant licenses can be purchased. • SIMATIC WinCC RT/RC (incl. Powerpacks) • SIMATIC WinCC/Server • SIMATIC WinCC/Redundancy • SIMATIC WinCC/Archives (incl. Powerpacks) • SIMATIC Logon All previously listed software components including options of SIMATIC BATCH and SIMATIC WinCC are supplied with the product SIMATIC BATCH for WinCC. In addition, supplementary components for configuring the interfaces between WinCC and SIMATIC BATCH are included in the basic package. The use and compatibility of WinCC and SIMATIC BATCH is only guaranteed for the software versions that come with SIMATIC BATCH for WinCC. Formula 1 Formula 2 Formula 3 Quantity 1 000 kg 500 kg 900 kg Temperature 90 °C 10 min 80 °C 15 min 95 °C 12 min Yes No 100 g Yes No 150 g No Yes 50 g Time Salt Pepper Sugar Master Recipe #1 Master Recipe #2 Master Recipe #3 The functions of SIMATIC BATCH for WinCC are based on the SIMATIC BATCH range of products. SIMATIC BATCH for WinCC includes the following licenses or functions: • SIMATIC BATCH Server for 10 units • SIMATIC BATCH CC (BATCH Control Center) • SIMATIC BATCH Recipe System (recipe editor) It can be used to run a SIMATIC BATCH project with 10 subsystems on a single-user station or a client/server combination (Batch Client and Batch Server). The capacity of the Server Basic Packages with 10 units can be expanded to 20, 40, 100 or unlimited units using SIMATIC BATCH Powerpacks. SIMATIC BATCH CC offers powerful functions for the following tasks: • Reading in and updating the plant data of the basic automation • Defining user privileges for all functions, for clients or subsystems • Definition of material names and codes • Managing master recipes and starting the recipe editor • Management of libraries with recipe elements (library operations) • Editing of formula categories and management of associated formulas (parameter sets) • Creation of batches with master recipes • Starting of batch processing and controlling of batches • Monitoring and diagnostics of batch processing • Recording and archiving of recipes and batch data Use of the "SIMATIC BATCH Hierarchical Recipe" license permits the creation of hierarchical recipes in accordance with ISA-88 The hierarchical recipe structure is mapped on the plant module as follows: • Recipe procedure for controlling the process or the production in a plant • Partial recipe procedure for controlling a process step in a plant unit • Recipe operation/function to implement the process engineering task/function in a technical facility G_PCS7_XX_00064 ■ Function The flexibility achieved by recipes which are independent of plant units can be increased even further if the procedure and parameter sets (formulas) are separated from one another. Various master recipes can be created by linking several formulas using a recipe procedure. This enables central modification of procedures. The formula structure is determined by the formula category defined by the user. Compatibility In respect of compatibility, please note that only the SIMATIC WinCC and SIMATIC BATCH versions included in the product package are compatible with each other. Only predecessor products of the product bundle SIMATIC BATCH for WinCC are upward compatible, not single components of the product range SIMATIC WinCC and SIMATIC BATCH. ■ Integration A detailed description of how to integrate SIMATIC Batch in WinCC appears in the interface description "SIMATIC BATCH Configuration Guide". ■ Ordering data Order No. SIMATIC BATCH for WinCC Software bundle for the creation of recipes and control of batch processes in accordance with ISA S88 based on SIMATIC BATCH. • SIMATIC BATCH Server 10 units • SIMATIC BATCH Recipe system (Floating License) • SIMATIC BATCH CC (Floating License) 6ES7657-1SA17-0YA0 Siemens ST 80 / ST PC · 2013 4/109 4 © Siemens AG 2013 HMI Software SIMATIC WinCC options SIMATIC Information Server ■ Overview View in the Web browser IS client Add-ins for Microsoft Word and Excel 4 The Information Server is the reporting system for WinCC and the Process Historian. Based on Microsoft Reporting Services, the historical data (tags and alarms) are made available via a web client. The Information Server Client does not need a client installation. Using a pure web client, it offers functionality for administration, configuration, and visualization of reports. Add-ins for Microsoft Office applications such as Word and Excel offer additional ways to access the WinCC and Process Historian database. Reports can be created automatically cyclically and sent by email. The Information Server can be used on a WinCC station, on a Process Historian, or independently. The basic package contains licenses for three clients and one data source. The available licenses are additive and refer to simultaneous access to the client computer. Pre-created report, such as for trends and alarms, are contained in the standard package. ■ Benefits • Central, web-based report system as interface for all corporate areas up to the management level. • Simple handling through use of standard tools such as Microsoft Word and Excel • Provision of freely configurable reports via the web • Automatic sending of reports via email • Import of data from any number of WinCC applications • Transparent access to WinCC tag and alarm logs as well as SIMATIC Process Historian data G_PCS7_XX_00298 Process Historian and information server (IS) Highlights: • Frequently used report templates for process values, messages, and batches • Open reporting system for creating any number of new report templates • Storage of configured (parameterized) report templates for faster access • Report export in common document formats • Support of subscriptions for cyclic report generation including email service • Creation and storage of role-based dashboards • Role management for Windows users; supports workgroups and Active Directory; user rights can be assigned for specific projects • Generation of reports and inserting as graphics in Microsoft Office Word documents • Creation of Microsoft Excel reports for historical process values and messages as well as storage of the Excel report templates on the Information • Server Support for subscriptions to Excel report templates ■ Ordering data SIMATIC Information Server 2013 "Basic Package" • Information server • Information Server Client access (3) • Information Server Datasource access (1) SIMATIC Information Server • 1 Client access • 3 Client access • 5 Client access • 10 Client access • 1 Datasource access • 3 Datasource access 4/110 Siemens ST 80 / ST PC · 2013 Order No. 6AV6361-2AA01-3AA0 6AV6361-2BD01-3BB0 6AV6361-2BE01-3BB0 6AV6361-2BF01-3BB0 6AV6361-2BG01-3BB0 6AV6361-2CD01-3BB0 6AV6361-2CE01-3BB0 © Siemens AG 2013 HMI Software SIMATIC WinCC options SIMATIC Logon ■ Overview ■ Function SIMATIC Logon Users receive a unique user ID, user name and password. This information is stored encrypted at a central point (for SIMATIC Logon in the Windows user management). Functions such as changing the password, automatic logoff after a predefined time and lockout after several incorrect entries of a password ensure maximum security of operation. In the case of the SIMATIC Logon, user administration is integrated into the security system and user administration of MS Windows. • SIMATIC Logon (SL) for WinCC is a software option package supporting the central administration of all WinCC users on a plant-wide basis. The central user management with SL uses the Windows mechanisms and is to be installed on all participating WinCC stations. The user management actions such as logging in and out are automatically supplied in the audit trail of WinCC/Audit and WinCC/ChangeControl by SL. • The WinCC/Audit or WinCC/ChangeControl and SIMATIC Logon options support users in respect of plant validation and meet the requirements of FDA CFR 21 Part 11. A declaration of conformity (White Paper) offers proof of this. ■ Benefits • Central, system-wide user management • Conforms with the requirements of the Food and Drug Administration (FDA) for the pharmaceuticals and food processing industry ■ Design The SIMATIC Logon Service can be used for the central user management of a number of WinCC stations. Operation in a Windows Workgroup or even in a domain is possible. To meet in particular the Food and Drug Administration (FDA) requirements for the pharmaceuticals and food processing industry, all user and administrator actions, such as log in, log out, password changes, incorrect password inputs, and creating and deleting users, are recorded with timestamp in a secure database or are available in the audit trail of WinCC/Change Control or WinCC/Audit. In addition, SIMATIC Logon allows setting up new users online, plant-wide and across applications, or blocking existing users. SIMATIC Logon also supports electronic signature. ■ Ordering data Order No. SIMATIC Logon V1.4 SP1 6ES7658-7BX41-2YA0 4 Central user management for WinCC V6.2 and WinCC V7.0 Runtime license for an operator station 1) SIMATIC Logon V1.5 upgrade 6ES7658-7BX51-0YA0 Single License, 7 languages (De, En, Fr, Es, Jap, Chin) 1) SIMATIC Logon included in scope of supply of WinCC ■ More information Information on FDA can be found in a White Paper: Declaration of conformity of SIMATIC WinCC for FDA21 CFR Part 11. http://www.siemens.com/automation/hmi/html_76/products/ software/wincc/fda01.htm Siemens ST 80 / ST PC · 2013 4/111 © Siemens AG 2013 HMI Software SIMATIC WinCC options SIMATIC Maintenance Station • Scalability: - Support of WinCC single-user stations and client/server configurations. - The SIMATIC Maintenance Station can be added to an existing WinCC project. • Consistency: - The maintenance view is generated from the control project and is consistent with it. • Flexibility in selection of devices: - Use of the PROFIBUS and PROFINET standards for device interfacing. - An additional proxy concept allows devices to be displayed that are not included in the STEP 7 hardware configuration or that do not support the standard diagnostics of PROFIBUS/ PROFINET. ■ Overview ■ Application 4 System-integrated plant asset management system • Automatic generation of a maintenance view in WinCC from the STEP 7 hardware configuration • Plant-wide visualization of all automation components from the management level to the field level in ready linked, hierarchically arranged WinCC displays • Mapping of central and distributed SIMATIC S7 components, PROFIBUS and PROFINET networks as well as associated bus nodes • Ethernet network components and industrial PCs can be integrated through SIMATIC NET SNMP OPC Server • Display of device status with group status generation in overview and detail displays • The device statuses "Maintenance required" and "Maintenance request" are supported for status-based maintenance • Provision of uniform faceplates showing detailed information for all components displayed • Display of the device identification data (electronic rating plate) • Integrated display of the status of the request ■ Benefits • Reducing down times: - Problems in the plant are detected sooner due to the uniform presentation and clear overview of all information that is important for maintenance. • Avoiding downtimes: - Support of condition-based maintenance. • Reduced maintenance costs: - Optimization of the flow of information between production and maintenance by submitting maintenance requests and presenting the status of requests. • Transparency and traceability: - All procedures are based on messages and can therefore be archived and traced. - A comprehensive database is generated that can be analyzed with WinCC functions or external tools. 4/112 Siemens ST 80 / ST PC · 2013 The SIMATIC Maintenance Station is a tool for the diagnosis and maintenance of machines and plants. This is an option package for STEP 7 V5.4 and WinCC V6.2 or V7.0 that generates a WinCC maintenance view for a STEP 7 project/multiproject. ■ Design The SIMATIC Maintenance Station is available in various different packages: • Basic package: Contains all the tools needed to configure a Maintenance Station and a license for the display of 100 devices. • Powerpacks: For larger quantities, powerpacks are available with licenses for 100, 500 or 1000 devices. These can be added to the existing licenses and can be combined as required. In this context, devices can be: • AS systems • Distributed devices (PROFIBUS / PROFINET) • PCs • Network components • Asset proxies Requirements for configuring a SIMATIC Maintenance Station • STEP 7 license (V5.4 upwards) • WinCC RC license (V7.0 upwards) • The SIMATIC NET licenses required for the plant configuration Requirements for operation of a SIMATIC Maintenance Station • The WinCC licenses (V7.0 upwards) complying with the plant configuration © Siemens AG 2013 HMI Software SIMATIC WinCC options SIMATIC Maintenance Station ■ Function ■ Technical specifications Hierarchic visualization of plant components in WinCC • Generation of a WinCC picture tree for hierarchic display of the plant components. • Automatic creation and linking of displays, equipment symbols, status indicators, faceplates and the required variables. • Presentation of the detailed data in faceplates with selectable views. • Easy navigation in the plant using the WinCC Picture Tree Manager. • Generated pictures can be enhanced using the WinCC Graphic Designer. • Switchover between a WinCC SCADA project and the picture tree of the SIMATIC Maintenance Station can be configured using standard WinCC functions. Hardware requirements System Operating system Display of the current status of the plant and its components • Clearly understandable status displays through the use of uniform symbols. • Display of no-fault status, fault, maintenance requirement and maintenance request. • Display of status of request for submitted repair requests. • Display of order status. • Display of the alarm status of the components. Engineering station "ES" Windows XP Professional SP3 Windows Server 2003 (R2) SP2 Windows Server 2008 R2 SP1 MS Windows 7 SP1. Supported versions: Ultimate and Professional Maintenance Station Stand-alone / WinCC-Station "Single-user Workstation" Windows XP Professional SP3 Windows Server 2003 (R2) SP2 Windows Server 2008 R2 SP1 MS Windows 7 SP1. Supported versions: Ultimate and Professional ES with Maintenance Station Stand-alone Windows XP Professional SP3 Windows Server 2003 (R2) SP2 Windows Server 2008 R2 SP1 Windows 7 SP1. Supported versions: Ultimate and Professional Maintenance Station Server / WinCC Server Windows Server 2003 (R2) SP2 Windows Server 2008 SP2 Windows Server 2008 R2 SP1 Maintenance Station Client / WinCC Client Windows XP Professional SP3 Windows Server 2003 (R2) SP2 Windows Server 2008 SP2 Windows Server 2008 R2 SP1 Windows 7 SP1. Supported versions: Ultimate and Professional Display of the identification data of the plant components • Display of the identification data available for a device in the faceplate for the device. • Automatic loading of the data available in the configuration into the maintenance station. • Reading of the "Identification & Maintenance functions (I&M1) )" in accordance with the PROFIBUS International specification. • Export2) of I&M data for all devices in the form of an XML file. Displaying alarms • Loading of system error messages from STEP 7. STEP 7 provides the messages in 5 languages3), translation into additional languages is possible in STEP 7. • Display of the most recent message in a message line. • Presentation of the active/archived messages of the selected device in the faceplate. System Clock frequency Main memory Free hard disk space Engineering station 2.8 GHz 1 GB 15 GB Maintenance Station Stand-alone / WinCC-Station "Single-user Workstation" 2.8 GHz 1 GB 15 GB Maintenance Station Server / WinCC Server 2.8 GHz 1 GB 15 GB Maintenance Station Client / WinCC Client 2.8 GHz 512 MB 3 GB Software requirements Calling the STEP 7 hardware configuration • The STEP 7 hardware configuration can be opened for a selected device using a button in the faceplate. STEP 7 and the project must be installed on the maintenance station for this purpose. 1) The Maintenance Station 2007 supports reading of I&M data for PROFIBUS devices with C1 channel access. 2) The I&M data loaded from the configuration are exported. 3) For Siemens components that are included in the STEP 7 hardware catalog. In the case of components that are integrated in STEP 7 using GSD files, the GSD files must support the relevant languages. Siemens ST 80 / ST PC · 2013 4/113 4 © Siemens AG 2013 HMI Software SIMATIC WinCC options SIMATIC Maintenance Station ■ Technical specifications (continued) ■ Ordering data Requirements for the integration of devices Type Integration SIMATIC S7 controllers / I/O • S7-300 1) Yes • S7-400 Yes • WinAC Yes Distributed devices • ET 200 Yes • PROFIBUS standard slaves Yes • PROFINET standard devices Yes Comment PROFIBUS DP and PROFINET IO according to STEP 7 hardware catalog Integration using a GSD file Integration using a GSD file Network components Ethernet network components Yes PROFINET network components Yes PROFIBUS diagnostic repeater Yes SIMATIC NET SNMP OPC Server and MIB also required Personal Computer 4 PC/Industrial PC Yes SIMATIC NET SNMP OPC Server also required Drives with PROFIBUS connection Yes For integrating devices designed to the PROFIDRIVE profile, Drive ES SIMATIC (V5.4 SP1 or higher) is required Drives with PROFINET connection Yes For integrating devices designed to the PROFIDRIVE profile, Drive ES SIMATIC (V5.4 SP1 or higher) is required Yes Integrated via function block (asset proxy) Drives Accessory devices Devices not configured in STEP 7 Hardware Config 1) With S7-300, PROFIBUS/PROFINET systems are supported if they are connected to the internal CPU interfaces 4/114 Siemens ST 80 / ST PC · 2013 Order No. SIMATIC Maintenance Station 2009 Can be used with STEP 7 V5.4 or higher and WinCC V7 • Basic package with engineering software (Floating License) and Runtime License for 100 devices • Powerpack 100 Runtime License for 100 additional devices • Powerpack 500 Runtime License for 500 additional devices • Powerpack 1000 Runtime License for 1000 additional devices • Basic demo package 2009 • Upgrade from SIMATIC Maintenance Station 2007 to SIMATIC Maintenance Station 2009 6ES7840-0WD01-0YA0 6ES7840-0WD11-0YD0 6ES7840-0WD21-0YD0 6ES7840-0WD31-0YD0 6ES7840-0WD01-0YA7 6ES7840-0WD01-0YE0 © Siemens AG 2013 HMI Software SIMATIC WinCC options SIMATIC Process Historian ■ Overview ■ Function Project A Project B OS clients Information server Terminal bus OS single station - OS server - Batch server Process Historian Automation systems G_PCS7_XX_00297 Plant bus The Process Historian is a high-performance tong-term archiving server solution that stores WinCC process values and messages in a central database. The system offers full scalability for performance and scope: It records and saves data from one or several WinCC and PCS 7 projects. The number of connected single stations, servers, or redundant server pairs is unrestricted. SIMATIC Process Historian is designed for use throughout your plant, below the corporate management level (ERP, MES). Process Historian is the basis for the Information Server reporting system, which accesses the central Process Historian database and ensures clear, user-friendly data visualization on WinCC stations and office PCs. • Real-time data storage of the WinCC archive data (process values and messages) from any number of WinCC stations • Visualization of the archive data on WinCC clients or WinCC single stations either directly or using the SIMATIC Information Server. Process Historian configuration tool for fast, simple engineering • The redundant Process Historian is based on Microsoft SQL Server Mirroring (third system for monitoring the availability of redundancy). • The database and segmenting are set up in the initial configuration. • For archiving to the PH, the PH Ready component is installed on the WinCC server • The PH automatically detects all connected WinCC server projects (via the PH Ready component) • The "Process Historian Management" dashboard for diagnostics, displaying data sources, changing the database segmentation ■ Ordering data Order No. SIMATIC Process Historian Server 2013 Single License 6AV6361-1AA01-3AA0 SIMATIC Process Historian Server 2013 Single License (Redundancy Complete) • 2x Process Historian Server • 2x Process Historian Server Redundancy 6AV6361-1BA01-3AA0 SIMATIC Process Historian 2013 Single License Redundancy 6AV6361-1CA01-3AA0 4 Upgrades Upgrade from CAS (Central Archive Server) V7.0 SP3 to Process Historian 2013 6AV6361-1AA01-3AE0 The central Process Historian database provides access to realtime data throughout the plant. This data is the key to sustainable plant optimization. Because this is a completely integratable archive system, the engineering can also be performed without additional effort. SIMATIC Process Historian uses the integrated relational database Microsoft® SQL Server. No complex reconfiguration is needed because the archive system is integrated in WinCC. Time or event-driven archiving of selected process values or messages in the WinCC long-term archive is possible. ■ Benefits • Fully integrated long-term archive solution for large volumes of data • Central, plant-wide long-term archive as company-wide information hub • Process data and messages can be archived from any number of lower-level WinCC systems • Plant expansions without interrupting the production process • High availability in redundant mode • High degree of security due to integrated backup system • Database for analyses with the goal of optimizing the plant and thus the productivity Siemens ST 80 / ST PC · 2013 4/115 © Siemens AG 2013 HMI Software SIMATIC WinCC options WinCC/Calendar Scheduler ■ Overview ■ Benefits • Simple operation, configuration and planning of events thanks to handling in the style of Microsoft Office Calendar • Simple configuration of the actions by parameterization (execution of WinCC scripts or writing of WinCC tags at certain times) • Configuration of recurring events taking account of configurable public holidays, vacation periods, and maintenance periods • Secure operation of the plant taking account of different authentication levels • Clear representation of events at runtime by means of Calendar Runtime Control • Flexible use in all typical WinCC plant configurations, client/server, redundant systems, WebNavigator ■ Function With the WinCC Calendar Scheduler, events and their associated actions can be configured in a user-friendly and clear way in an editor in WinCC Explorer. 4 • Option for SIMATIC WinCC for managing events in a calendar. • Setting WinCC variables or starting global scripts at defined times. • A license is only necessary on the server (or single user system). The events are represented in a calendar. The period represented can be freely selected. Recurring events can be defined as serial events with any desired exceptions. The events are displayed in a .Net control. The Calendar Scheduler is easy and intuitive to operate and supports drag & drop during configuration and runtime. ■ Ordering data Order No. WinCC/Calendar Scheduler • for WinCC V7.2 • for WinCC V7.0 SP3 4/116 Siemens ST 80 / ST PC · 2013 6AV6372-1DC07-2AX0 6AV6372-1DC07-0AX0 © Siemens AG 2013 HMI Software SIMATIC WinCC options WinCC/Central Archive Server (CAS) ■ Overview Central data management, reliable, high-performance archiving and central backup mechanisms form the basis of a Process Historian solution: Integration in the SCADA world, data interfaces for access to archived data and analysis functions are the component parts. The option CAS was designed for this purpose and is used to export the archived data of all servers in the system to a computer and manage it. Integration of CAS in the WinCC world means that the data remains available for the WinCC clients as well as for the WinCC standard interfaces. WinCC/CAS contains all licenses for the central archive server including 1500 archive tags. The number of archive tags can be increased to 120000 using Powerpacks or further WinCC archives. ■ Benefits • Central data management of all archived alarms and process values • Integrated back-up system for the archive data • Transparent access to the data from all WinCC clients and over the open interfaces • Integrated Web viewer for analyzing data ■ Function Both the process value archive and alarm log are created on the separate WinCC servers and transferred to CAS when individual database segments have been closed. With "Store&Forward", when the network is interrupted between the WinCC server and CAS, data will be reliably transferred as soon as the network is operating again. Data access is transparent for display and analysis and is still possible through the standard WinCC clients. For the clients, it is of no consequence whether the data are on the WinCC server or already on CAS. Data saved in CAS can also be viewed using the Web viewer included in the package. The data of the distributed WinCC system can also be accessed through the familiar interfaces (OPC DA, OPC A&E, OPC HDA and Ole-DB) with the help of the Connectivity Pack or the Connectivity Station. In this manner, the data saved in CAS can be efficiently transferred to higher-level systems or used for the purposes of analysis. ■ Ordering data Order No. WinCC/CAS V7.0 SP3 basic packages • WinCC/CAS V7.0 SP3 • WinCC/CAS V7.0 SP3 ASIA 6AV6371-1DQ17-0XX0 6AV6371-1DQ17-0XV0 WinCC/CAS upgrade • V6.2 to V7.0 SP3 • V6.2 ASIA to V7.0 SP3 ASIA 6AV6371-1DQ17-0XX3 6AV6371-1DQ17-0XV3 WinCC/CAS V6.2 SP3 basic packages • WinCC/CAS V6.2 SP3 • WinCC/CAS V6.2 SP3 ASIA 6AV6371-1DQ16-2XX0 6AV6371-1DQ16-2XV0 4 Note: Standard Archive Powerpacks (see WinCC ordering data) can also be used for WinCC/Central Archive Server (CAS) WinCC V7.2 is not supported. The successor product is the option Process Historian for V7.2. Siemens ST 80 / ST PC · 2013 4/117 © Siemens AG 2013 HMI Software SIMATIC WinCC options WinCC/ChangeControl & WinCC/Audit ■ Overview 4 ■ Benefits • WinCC/ChangeControl is used to trace engineering changes in a tamper-proof long-term audit trail database, called the audit trail for short. All changes are automatically entered in the engineering system in the audit trail. This enables all the changes to be traced that have been made, to deduce the causes and minimize downtimes on the system. To begin tracing at a defined project status, a project version definition is provided that contains all data and files of a WinCC project version. The project version definition naturally provides the ability to reactivate earlier project versions. Document management is also provided, which manages and archives intermediate status for system graphics, reports or user files and stores change information of the user. An audit viewer with helpful filter functions can be used for quickly and simply evaluating the audit trail, exporting it to an Excel sheet or printing it out. • WinCC/Audit Includes the full functionality of WinCC/ChangeControl and is also used for tracing all operations. All operations are automatically recorded in the audit trail at RT. • Licensing : To configure which change information from the project should be recorded in the audit trail, the WinCC/ChangeControl RC or WinCC/Audit RC package is required. "RC" stands for Runtime and Configuration. It is required on the station that is to be configured and also includes an RT license. For recording an audit trail, one WinCC/Audit RT license is required per WinCC station (Client/Server). • The WinCC/Audit or WinCC/ChangeControl and SIMATIC Logon options support users in respect of plant validation and meet the requirements of FDA CFR 21 Part 11. A declaration of conformity (White Paper) offers proof of this. 4/118 Siemens ST 80 / ST PC · 2013 • Quick and easy traceability configuration • Gap-free and automated recording of engineering changes and operator actions in an audit trail • Reduction in plant downtimes thanks to fast analysis of the gap-free recorded audit trail information • Logging of defined WinCC project status with all database information and files of the application • Gap-free documentation of the project version definition procedures with version number, user and comments • Complete tracing support by WinCC single and multi-station systems, single and multi-project solutions, Client/Server architecture • Extensive reduction in engineering outlay in order to meet the requirements of FDA 21 CFR Part11 & EU 178/2002 • Compliance with the requirements of the Food and Drug Administration (FDA) for the pharmaceutical and food industries. ■ Design WinCC/ChangeControl and WinCC/Audit consist of five components: • The audit editor for configuration the audit trail content • The project version definition for logging WinCC projects • Document management for automatic archiving and versioning of WinCC plant mimics, scripts, reports, and project-specific documents, and the recording of the associated change information • The audit viewer for visualizing, exporting and printing WinCC and WinCC flexible audit trails. The viewer is available as an executable program under Windows, as well as OCX with WinCC Runtime. • The audit trail, which tracks all changes in respect of both engineering and plant operation in a separate SQL database. The audit trail can be set up as a central audit trail for a number of projects or even just for a single project. WinCC/ChangeControl and WinCC/Audit support both singleuser and multi-user systems, client/server architectures and even the WinCC redundancy system. No redundant audit trail is created however. © Siemens AG 2013 HMI Software SIMATIC WinCC options WinCC/ChangeControl & WinCC/Audit ■ Function WinCC/ChangeControl WinCC/ChangeControl is a functional subset of WinCC/Audit. WinCC/ChangeControl is for tracing engineering changes in the engineering phase or in online operation. All change data is recorded in an audit trail. There are two types of engineering changes: • those that change the WinCC database or are executed through the WinCC Explorer, such as e.g. changes to tag management or creating a user group, and those • limited to changing files, the so-called document administration. The document management manages system images, scripts and log layouts and customer-specific documents and stores respective intermediate versions as backups. All of these documents or files are subject to a change process, i.e. documents can be booked out for processing, booked in for finalization and intermediate versions can be retrieved from backup storage with a rollback function. The project version definition as a component of WinCC/ChangeControl archives WinCC projects and creates reproducible project status or defined start-time points for starting tracing. An audit trail is also provided with information on who has created which project version or which version has been reproduced or deleted. Configuring the audit trail, the project version definition and the document management is simple, quick and comfortable. The audit trail data is visualized from WinCC, as well as from WinCC flexible via the audit viewer, an executable program under Windows. The data can also be evaluated with the audit viewer OCX in Runtime by WinCC however. Users select the desired view of the audit trail information via filters or selection criteria and can export the data to an Excel file or print it on a printer. Audit trail information is tamper-proof and can thus not be modified or deleted. An export function can be used to swap out the audit trail to an XML file or to archive it. ■ Ordering data Order No. WinCC/ChangeControl For the configuration of the audit trail incl. RT • WinCC V7.0 SP3 • V6.2, for WinCC V6.2 and WinCC V6.2 SP2/SP3 6AV6371-1DV27-0AX0 6AV6371-1DV26-2AX0 WinCC/Audit RC For the configuration of the audit trail incl. RT • WinCC V7.0 SP3 • V6.2, for WinCC V6.2 and WinCC V6.2 SP2/SP3 6AV6371-1DV17-0AX0 6AV6371-1DV16-2AX0 WinCC/Audit RT Creation of audit trails in RT • WinCC V7.0 SP3 • V6.2, for WinCC V6.2 and WinCC V6.2 SP2/SP3 6AV6371-1DV07-0AX0 6AV6371-1DV06-2AX0 Upgrades V6.x to V7.0 • for WinCC/Audit RT • for WinCC/Audit RC or WinCC/ChangeControl 6AV6371-1DV07-0BX4 6AV6371-1DV17-0BX4 V6.x to V6.2 • for WinCC/Audit RC and WinCC/Audit RT 6AV6371-1DV06-2AX3 4 ■ More information Information about FDA can be found in a White Paper: Declaration of conformity of SIMATIC WinCC to FDA21 CFR Part 11. http://www.siemens.com/automation/hmi/html_76/products/ software/wincc/fda01.htm WinCC/Audit WinCC/Audit has all of the functionality of WinCC/ChangeControl and is also used for tracing user operations in RT operation. Tracing can be used for determining who, when and what conditions the machine has undergone. In addition to recording operator activities, the audit trail also records the starting and modifying of recipes or user logs. At specific objects or events, such as function buttons or sliders, the user can also record activities of an individual nature such as e.g., pressing a function button, moving sliders and other actions with a so-called audit entry function in the audit trail. A WinCC/ChangeControl RC license or a WinCC/Audit RC license is required for configuring the audit trail. One RT license is required for each station (client/server) to be monitored. One RC license always includes one RT license. Siemens ST 80 / ST PC · 2013 4/119 © Siemens AG 2013 HMI Software SIMATIC WinCC options WinCC/Connectivity Pack & WinCC/Connectivity Station ■ Overview MES Online data access to variables OPC DA OPC XML DA OPC UA DA ERP MES Online messages forward/acknowledge OPC A&E Online data access to historical data OPC HDA OPC UA HDA VB (.NET), VB Script, VBA Database access through 3rd party application WinCC OLE-DB SIMATIC WinCC 4 Cross-vendor communication in the automation sector has always been of primary importance for WinCC. This is even more true for the release of preprocessed production data for higherlevel information systems (e.g., MES = Management Execution System, ERP = Enterprise Resource Planning or Office packages = MS Excel, MS Access etc.). WinCC features integrated OPC Data Access and OPC XML DA servers for access to all online values in the system and makes open interfaces available for access to historical WinCC data. • The Connectivity Pack includes OPC XML DA 1.00, OPC HDA 1.20 (Historical Data Access), OPC A&E 1.10 (Alarm & Events) and a WinCC OLE-DB interface which even allows remote computers without WinCC to access WinCC archive and alarm data. • The function of the OPC servers (XML DA, HDA and A&E) is assured by the WinCC/Connectivity Pack. In order to access data in the database via WinCC OLE-DB/OLE-DB, you will also need a license for the WinCC/Connectivity Pack. ■ Benefits • Access to variables, historical WinCC data, alarm data and user archives from any computer • Options for analyzing and evaluating process data with specialist tools or user-defined applications (e.g., via VisualBasic) 4/120 Siemens ST 80 / ST PC · 2013 MS SQL Server G_ST80_XX_00066 WinCC/ConnectivityPack • A Connectivity Pack license is required for every WinCC system to be accessed. • If the Connectivity Station is used, an additional Connectivity Pack license does not have to be installed on the WinCC systems that are accessed. The Connectivity Station functions autonomously and does not require a WinCC installation on the computer. • For versions below V7.0 Access to WinCC archive and alarm data from a computer without installed WinCC basic system license or WinCC option via the interfaces of the Connectivity Pack or Connectivity Station requires a WinCC/Client Access license on the client side (see also "WinCC/Client Access License"). • Connectivity Station Option for WinCC V6.2 and higher © Siemens AG 2013 HMI Software SIMATIC WinCC options WinCC/Connectivity Pack & WinCC/Connectivity Station ■ Function As an OPC HDA server, WinCC makes historical data from the WinCC archive system available to other applications. An OPC HDA client (e.g. a reporting tool) can define the time interval for the required data by entering a start and end time. OPC HDA servers also support the generation of a variety of aggregate functions on the server itself (e.g. standard deviation, variance, mean values, integral values, etc.), thereby helping to relieve the load on the network, as only preprocessed data are transmitted. OPC A&E servers are used to forward WinCC messages (along with all associated process values) to any client at production or enterprise control level. Filter mechanisms and subscriptions ensure that only selected modified data are transmitted. Acknowledgement is of course also supported. The WinCC OPC XML DA server makes cross-platform communication between Windows and non-Windows systems possible, even via the Internet. This enables read and write WinCC online values (external and internal WinCC variables) to be exchanged with non-Siemens systems. WinCC OLE-DB makes standardized and user-friendly access to WinCC archive data possible (MS SQL Server 2005). In exactly the same way as access via the OPC HDA and OPC A&E interfaces, access via the WinCC OLE DB provider makes all WinCC archive data available along with the associated process values and message/user texts. The WinCC OLE-DB provider also supports analysis functions such as minimum, maximum, message hit list, etc. The WinCC Connectivity Station was designed as a stand-alone gateway to WinCC server data. It supports access to WinCC server data over the OPC channels described as well as those for process values (not alarms) over OLE DB . Access to WinCC data is transparent, i.e. independent of which server of a redundant pair is active or whether data have already been transferred to the central archive server. Connectivity Station If no visualization is required at a station, any Windows computer with access to WinCC via OPC and OLE-DB can be configured via the Connectivity Station. This permits access to WinCC stations with server packages from a central computer without WinCC installation. The WinCC stations can be accessed via the following interfaces: • OPC interfaces of the Connectivity Station • OLE DB interface of the Connectivity Pack The two access variants are autonomous access options with different ranges of functions. OPC interfaces of the Connectivity Station The Connectivity Station provides interfaces via which you can access the following using an OPC-Client. • OPC-DA-Server: tags, e.g. process values • OPC-HDA-Server: archived process values • OPC-A&E-Server: alarms Licensing You require the "WinCC Connectivity Station" license in order to utilize the OPC interfaces of the Connectivity Station on a computer without WinCC installed. If you only use the OPC interfaces of a WinCC installation, you only need the "Connectivity Pack" license. The following table shows the combinations: New: WinCC-independent installation with Connectivity Station Standard installation: OPC with WinCC OPC DA "WinCC Connectivity Station" license No license required OPC HDA "WinCC Connectivity Station" license "WinCC Connectivity Pack" license OPC A&E "WinCC Connectivity Station" license "WinCC Connectivity Pack" license "WinCC OPC UA HDA Connectivity Pack" license OPC UA DA The Connectivity Station is planned over NCM PC Manager or SIMATIC Manager. In Version 7, the Connectivity Station does not run as service. ■ Ordering data 4 Order No. WinCC/Connectivity Pack & WinCC/Connectivity Station V7.2; for WinCC V7.2 Basic packages • WinCC/Connectivity Pack V7.2 1) • WinCC/Connectivity Station V7.2 1) 6AV6371-1DR07-2AX0 6AV6371-1DR17-2AX0 V7.0; for WinCC V7.0, WinCC V7.0 SP1/SP2/SP3 and WinCC V7.0 SP1/SP2/SP3 ASIA Basic packages • WinCC/Connectivity Pack V7.0 1) • WinCC/Connectivity Station V7.0 1) 6AV6371-1DR07-0AX0 6AV6371-1DR17-0AX0 V6.2 SP3; for WinCC V6.2 SP3 and WinCC V6.2 SP3 ASIA Basic packages • WinCC/Connectivity Pack V6.2 SP3 • WinCC/Connectivity Station V6.2 SP3 • WinCC/Connectivity Pack V6.2 SP3 ASIA • WinCC/Connectivity Station V6.2 SP3 ASIA Upgrade1) • WinCC/Connectivity Pack V6.x -> V6.2 SP3 1) 6AV6371-1DR06-2AX0 6AV6371-1DR16-2AX0 6AV6371-1DR06-2AV0 6AV6371-1DR16-2AV0 6AV6371-1DR06-2AX3 Upgrades from V6.x to V7.x are included in the WinCC V7.x upgrades Siemens ST 80 / ST PC · 2013 4/121 © Siemens AG 2013 HMI Software SIMATIC WinCC options WinCC/DataMonitor ■ Overview 4 ■ Benefits • The WinCC/DataMonitor is a component of WinCC Plant Intelligence and is used for displaying and evaluating current process statuses and historical data on office PCs with standard tools such as Microsoft Internet Explorer or Microsoft Excel. The DataMonitor client is provided with current and historic process data and alarms by a DataMonitor server. All staff ranging from machine operators to corporate managers can use the DataMonitor to obtain information. • DataMonitor is a suite of Internet-capable tools: - Process Builder - Tool for simple visualization and navigation with WinCC screens using WinCC Web Viewer (WinC Viewer RT) in "view only" mode - Excel Workbooks - Protocol tool that integrates WinCC archives and online values into MS Excel and supports online analysis - Published Reports - Event- or time-driven execution of Excel or PDF reports for the output of process data and analysis results - Web center - Individual configuration of Internet pages and summary of information within a portal in terms of WinCC applications - Trends and alarms are preconfigured Web Center pages • DataMonitor does not require manual client installation because it loads the required components from the DataMonitor server • There is no installation required on the client for the Webcenter, Trends and Alarms functions. • Licenses for simultaneous access by 1, 3, 10, 25 or 50 DataMonitor clients. Any combination of DataMonitor and Web Navigator licenses can be used for an application. • Preconfigured Web Center pages permit ad hoc entry 4/122 Siemens ST 80 / ST PC · 2013 • Information can be compiled online individually during runtime via the Internet/intranet. • Efficiently monitor and analyze production lines. - Display and evaluation of current process states and historical data on remote office PCs with standard tools such as Microsoft Internet Explorer or Excel. - Easy access to production data via the intranet or Internet - Quick ascertainment of the production situation - Use of standard products • Easily collect and distribute information. - Automated report creation - No additional configuration effort through direct use of images from the WinCC project - No training required for standard products - Easy exchange of configuration data • Substantiate decisions with reports. - Evaluation via ready-made templates for special analyses of the business processes (e.g. reports, statistics) - Make bottlenecks transparent - Individual views for user and situation - Relative and absolute timeframe for information generation • View production status anywhere and anytime. - Individual views of information in production - View the process and system operation - Historical data can be compiled online individually Highlights • Access to the lower-level servers when installing the DataMonitor server on a WinCC Client with separate project (RT128 license) • Tag logging archive tags can be accessed by means of the web center function without changing the WinCC configuration system. • Installation of the DataMonitor web center function on a WinCC file server • Dedicated Internet pages can be created for displaying data with the Webcenter. For this purpose, the following tools which can be integrated in the Internet sites are available. - Bar diagram, pie chart, trend curve display - Process value table and statistics functions for the process values - Alarms, hit list for alarms - Message text display for individual message texts, message display, selection list of created reports - Links to internal and external pages - Display of graphics in converted jpg format - Display of the WinCC process images • The analyses can be made with relative or absolute time specification. This enables comparisons of identical time periods on different days. • Reports generated with Excel or the WinCC Report Designer can be made available on the DataMonitor server or e-mailed automatically to the relevant group of people based on time intervals or triggered by events. • Connections can be established to WinCC Runtime, the central archive server, and the swapped-out archives © Siemens AG 2013 HMI Software SIMATIC WinCC options WinCC/DataMonitor ■ Benefits (continued) New in V7.2 • DataMonitor - In V7.2 or higher, the upgrade license is contained in the corresponding WinCC version - Supports Internet Explorer V 7.0, V8.0 and V9.0, including tabbed browsing. - Excel reports can be generated with Microsoft Excel version 2003 / 2007 / 2010 ■ Function • All tools are fully Internet-compatible and, therefore, support access via any type of connection (LAN, GSM, radio, modem, Internet, etc.). • All popular security mechanisms such as login/password, firewalls, encryption, etc. are supported. • Users can combine the available tools at will. Licensing only takes into account simultaneous access to one Web server. • For display purposes, screens from the WinCC project can be used or special overview displays configured. Animations, scripts, navigation and access rights remain valid. • The WinCC/DataMonitor has purely a display function. • Company-wide Excel reports, which contain historical and current process values, can be stored centrally for general access (reports, statistics). However, local queries to meet individual requirements can be compiled and executed online. Plot and tabular representation are supported for archive data already swapped out. • Data can be automatically entered into created report templates and distributed by e-mail or saved on the server. • The screens are displayed in the WinCC Web Viewer or in the Internet Explorer in the view only mode of the Web Navigator. • Enhanced user management for the web center in order to assign individual Internet pages and created reports to specific user groups. • Integrating WinCC process screens on Internet pages without installation download • A search function facilitates the management of connections to the WinCC Server. • Swapped out archives can be connected and evaluated in the DataMonitor Web center. Expansion of the display area in the Web center (Menu Hide function) • Excel reports created offline can be loaded onto the DataMonitor server and are thus made available to selected user groups or for automatic distribution. • Pre-made elements make the assembly of individual web pages easier for evaluating information. • Individual information compilation on one or more Internet pages with the option of branching to other detail pages. • Pre-made Internet pages for trend and alarm display enable an ad-hoc entry to Internet data evaluation. • An higher-level navigation feature provides a common framework for the various tools. ■ Ordering data Order No. WinCC/DataMonitor V7.2 for WinCC V7.2 and WinCC V7.2 ASIA • 1 client license • 3 client licenses • 10 client licenses • 25 client licenses • 50 client licenses 6AV6371-1DN07-2LX0 6AV6371-1DN07-2AX0 6AV6371-1DN07-2BX0 6AV6371-1DN07-2CX0 6AV6371-1DN07-2DX0 WinCC/DataMonitor Powerpacks V7.0 • From 1 to 3 clients • From 3 to 10 clients • From 10 to 25 clients • From 25 to 50 clients 6AV6371-1DN07-2LA0 6AV6371-1DN07-2AB0 6AV6371-1DN07-2BC0 6AV6371-1DN07-2CD0 WinCC/DataMonitor V7.0 for WinCC V7.0, WinCC V7.0 SP3 and WinCC V7.0 SP3 ASIA • 1 client license • 3 client licenses • 10 client licenses • 25 client licenses • 50 client licenses 6AV6371-1DN07-0LX0 6AV6371-1DN07-0AX0 6AV6371-1DN07-0BX0 6AV6371-1DN07-0CX0 6AV6371-1DN07-0DX0 WinCC/DataMonitor Powerpacks V7.0 • From 1 to 3 clients • From 3 to 10 clients • From 10 to 25 clients • From 25 to 50 clients 6AV6371-1DN07-0LA0 6AV6371-1DN07-0AB0 6AV6371-1DN07-0BC0 6AV6371-1DN07-0CD0 WinCC/DataMonitor, Upgrade • from V6.0 to V7.0 • from V6.2 to V7.0 • from V6.x to V6.2 SP3 • from V6.x ASIA to V6.2 SP3 ASIA 6AV6371-1DN07-0XX4 6AV6371-1DN07-0XX3 6AV6371-1DN06-2XX3 6AV6371-1DN06-2XV3 WinCC/DataMonitor V6.2 SP3 for WinCC V6.2 SP3 • 1 client license • 3 client licenses • 10 client licenses • 25 client licenses • 50 client licenses 6AV6371-1DN06-2LX0 6AV6371-1DN06-2AX0 6AV6371-1DN06-2BX0 6AV6371-1DN06-2CX0 6AV6371-1DN06-2DX0 WinCC/DataMonitor V6.2 SP3 ASIA for WinCC V6.2 SP3 ASIA • 1 client license • 3 client licenses • 10 client licenses • 25 client licenses • 50 client licenses 6AV6371-1DN06-2LV0 6AV6371-1DN06-2AV0 6AV6371-1DN06-2BV0 6AV6371-1DN06-2CV0 6AV6371-1DN06-2DV0 WinCC/DataMonitor, Powerpacks V6.2 • From 1 to 3 clients • From 3 to 10 clients • From 10 to 25 clients • From 25 to 50 clients 6AV6371-1DN06-2LA0 6AV6371-1DN06-2AB0 6AV6371-1DN06-2BC0 6AV6371-1DN06-2CD0 Siemens ST 80 / ST PC · 2013 4 4/123 © Siemens AG 2013 HMI Software SIMATIC WinCC options WinCC/DowntimeMonitor ■ Overview ■ Benefits • Recording failure times, localizing causes and reasons for failure times, and monitoring of equipment efficiency. • Weak-point analysis in production processes and recording of undesirable process activities. • Basis for decision making based on performance indicators. • Identification of the events that lead to cost-intensive failures. • Entry point for an extended downtime analysis with upgrade options in the MES software SIMATIC IT. • Identification of speed and quality losses. • Complete transparency for all machines as basis for optimizing the plant's productivity. Faults and bottlenecks are prevented to increase availability. • Derivation of specific parameters (KPI - Key Performance Indicators). • Integration of respective display instruments (controls) in WinCC process images. • Can be utilized for individual machines or even complete production plants. • Distribution of evaluations to various people over the web. 4 The entry point to SIMATIC Plant Intelligence can be through options for the SIMATIC WinCC process visualization system. The WinCC/DowntimeMonitor is a component of WinCC Plant Intelligence and is used for monitoring the efficiency and performance of individual machine modules, subsystems and production lines. The combined elements to be monitored are designated as equipment. Using the WinCC/DowntimeMonitor, the machine data management software, standstill time can be recorded and analyzed centrally in production. For individual devices, machines or entire production lines, the specific parameters can be determined this way. Integration into WinCC ensures complete transparency of all machine and plant data as a basis for optimizing the plant's productivity. The process values are read directly from WinCC and are connected with the respective analysis function. • The SIMATIC WinCC DowntimeMonitor can be installed on a WinCC single station, WinCC Server or WinCC Client with project (RT128 license), and consists of an Engineering Client as well as a Runtime User interface. • All engineering operations are performed using a graphic Engineering Client. The Engineering Client is called up from the WinCC Explorer. • SIMATIC WinCC DowntimeMonitor provides ActiveX control elements. These are used for displaying the determined parameters and the progress of the various status over a certain time period. These controls are integrated in WinCC process images for presenting results. • The recorded data is stored in an online database set and can be moved to an offline database set. • The basic package consists of the Engineering and Runtime software and 5 licensed equipment units. Other licenses are available for up to 25, up to 50, 100 and up to 200 equipment units. 4/124 Siemens ST 80 / ST PC · 2013 ■ Function • Creation of a time model by defining various time categories as a basis for the KPI calculation for elements (equipment) to be evaluated. • Creation of equipment, as central components for the evaluation by dividing the system into individual groups. • Creation of a Reason Tree for detailed display of reasons for downtimes. • Allocation of the system status in the controller to the time categories and Reason Trees defined in the DowntimeMonitor. • Storing the system status for calculating and presenting Key Performance Indicators. • The following pre-defined Key Performance Indicators are available: Availability, change-over, cycle time, failure time loss, duration, effective performance, maintenance, Mean Time Between Assist (MTBA), Mean Time Between Failures (MTBF), Mean Time To Assists (MTTA), Mean Time To Repair (MTTR), failure time frequency, Overall Equipment Effectiveness (OEE), performance rate, production duration, quality rate, speed loss, Total Efficient Equipment Performance (TEEP), utilization. • Integration of three new controls Gant View, KPI View, and Table View in WinCC for the display of results for one or more equipment units. • The WinCC DowntimeMonitor Gant View presents the equipment status development within a certain time period. • The WinCC DowntimeMonitor KPI View shows the distribution of failure times and the Key Performance Indicators in a trend, bar, segmented bar charts or Pareto chart using historical data. • The WinCC DowntimeMonitor Table View shows raw data for failure times and analyzes it in the selected time period. The user can utilize these control elements to enter, change, distribute or combine and comment on failure times manually. • The controls can be displayed on intranet or Internet using the option WinCC/Web Navigator. © Siemens AG 2013 HMI Software SIMATIC WinCC options WinCC/DowntimeMonitor ■ Ordering data WinCC/DowntimeMonitor V7.0 SP3 for WinCC V7.0 SP3 and WinCC V7.0 SP3 ASIA • 5 equipment units • 25 equipment units • 50 equipment units • 100 equipment units • 200 equipment units Order No. Order No. 6AV6372-1DB07-0BX0 6AV6372-1DB07-0DX0 6AV6372-1DB07-0FX0 6AV6372-1DB07-0HX0 6AV6372-1DB07-0KX0 WinCC/DowntimeMonitor V1.0 SP1 for WinCC V6.2 SP2 and WinCC V6.2 SP2 ASIA • 5 equipment units • 25 equipment units • 50 equipment units • 100 equipment units • 200 equipment units 6AV6372-1DB06-2BX0 6AV6372-1DB06-2DX0 6AV6372-1DB06-2FX0 6AV6372-1DB06-2HX0 6AV6372-1DB06-2KX0 WinCC/DowntimeMonitor Powerpacks V7.0 • From 5 to 25 equipment units • From 25 to 50 equipment units • From 50 to 100 equipment units • From 100 to 200 equipment units 6AV6372-1DB07-0BD0 6AV6372-1DB07-0DF0 6AV6372-1DB07-0FH0 6AV6372-1DB06-2HK0 WinCC/DowntimeMonitor Powerpacks V1.0 • From 5 to 25 equipment units • From 25 to 50 equipment units • From 50 to 100 equipment units • From 100 to 200 equipment units 6AV6372-1DB06-2BD0 6AV6372-1DB06-2DF0 6AV6372-1DB06-2FH0 6AV6372-1DB06-2HX0 WinCC/DowntimeMonitor upgrade • V1.x to V7.0 SP3 6AV6372-1DB07-0XX4 Note WinCC V7.2 is not supported. 4 Siemens ST 80 / ST PC · 2013 4/125 © Siemens AG 2013 HMI Software SIMATIC WinCC options WinCC/Event Notifier ■ Overview ■ Benefits • Simple operation, configuration and planning of notifications thanks to handling like the Microsoft Office Calendar • Easy configuration of the notifications including support of the WinCC Runtime languages by connecting to the WinCC alarm system • Configuration of recurring events taking account of configurable public holidays, vacation periods, and maintenance periods • Secure operation of the plant taking account of different authentication levels • Clear display and intuitive operation at runtime by means of Calendar Control • Flexible use in all typical WinCC plant configurations, single station, client/server, redundant systems, WebNavigator ■ Function 4 • Option for SIMATIC WinCC for notifying selected persons by e-mail in specified time slots • Notification depends on events occurring in the WinCC Alarm System. • Escalation levels, i.e. Group 2 is only notified when nobody "on site" or from Group 1 has reacted within a specified time. • Final notification of all persons previously notified in connection with the specific event about the reaction that has taken place A license is only necessary on the server (or single user system). The WinCC Event Notifier enables the following to be configured in a clear and user-friendly manner via the Calendar Options Editor in the WinCC Explorer: • The e-mail service for sending and receiving messages • The messages by selecting configured messages in the WinCC Alarm System as well the setup and contents of the message by selecting the message blocks • Contacts by selecting predefined persons from the WinCC user administration. In a calendar it is then possible to select the persons to be notified within in the opened time slot from the existing contacts. If several persons or groups of persons are set up for the same time slot, escalation levels can be implemented by assigning different escalation times (= dead time before notification). The period represented by the calendar can be freely selected. Recurring events can be defined as serial events with any desired exceptions. The calendar can also be integrated as .Net Control in WinCC screens; the appearance of the calendar controls at runtime is configurable. Via the calendar control, you can create time slots during runtime with contacts who should be notified upon occurrence of the configured events in the WinCC Alarm System. In addition, the calendar control allows the creation of new contacts by means of selection from the WinCC user management. The Event Notifier is easy and intuitive to operate and supports drag & drop during configuration and runtime. ■ Ordering data Order No. WinCC/Event Notifier • for WinCC V7.2 • for WinCC V7.0 SP3 4/126 Siemens ST 80 / ST PC · 2013 6AV6372-1DD07-2AX0 6AV6372-1DD07-0AX0 © Siemens AG 2013 HMI Software SIMATIC WinCC options WinCC/IndustrialDataBridge ■ Overview WinCC V7 WinCC Professional SIMATIC NET OPC Server OPC DA & OPC XML DA Online Data Exchange Microsoft Office MS Excel File (csv) Online Data Storage Microsoft Office MS Access Online Data Exchange Microsoft SQL Server Online Data Reading My Oracle My SQL Data Export SIMATIC WinCC OPC DA WinCC User Archive • The WinCC/IndustrialDataBridge option uses standard interfaces in order to connect the automation world with the world of IT and ensure two-way information flow. Typical examples of such interfaces are OPC in the field of automation and SQL database interfaces in the world of IT. • With the SIMATIC WinCC/IndustrialDataBridge, simple configuration/parameterization of communication connections between various data sources and data destinations can be created. The IndustrialDataBridge can be integrated into WinCC and can also be used in stand-alone mode (not in conjunction with WinCC). • For example, SIMATIC WinCC with its OPC DA server interface is the data source and an external database is the data destination. - Highly flexible, thanks to support for various database formats and standard interfaces - Fast and secure thanks to configuration instead of programming G_ST80_XX_00067 WinCC/IndustrialDataBridge MS SQL Server OLE-DB (Alarm-, Tag logging) • In addition to access to WinCC variables, access to messages, process values and user archive data (in the WinCC database) is also supported. • WinCC/IndustrialDataBridge can be used as stand-alone application with its standard interfaces. • Option from WinCC V6 • For versions below V7.0 On a computer without a license for the WinCC basic system or a WinCC option, which is to be accessed in read/write mode by the option WinCC/IndustrialDataBridge, a WinCC Client Access License is required (see also "WinCC/Client Access License"). ■ Benefits • Connecting the automation level with the IT world • Integration of systems from different manufacturers via a host of standard interfaces (including OPC, OLE-DB, Office formats) • Simple configuration with standard software without programming and thus at low cost • High-performance data transfer between several systems simultaneously ■ Design The software comprises a configuration environment and a runtime environment. The different data interfaces are integrated via software modules. In each case, one module is required as the data source and one module as the data destination. The different modules can be combined in any way. The connections between data source and data destination are created in the configuration environment. In the runtime environment, the IndustrialDataBridge establishes the connection autonomously and transfers the data of the linked variables. Siemens ST 80 / ST PC · 2013 4/127 4 © Siemens AG 2013 HMI Software SIMATIC WinCC options WinCC/IndustrialDataBridge Interfaces: ■ Function 4 • IndustrialDataBridge establishes a link between the source and destination interfaces and transfers data on the basis of a change in value, once a configurable period of time has elapsed or when a specific event occurs. • IndustrialDataBridge exchanges data between automation systems from different vendors, e.g., via OPC. The connection of OPC servers via IndustrialDataBridge enables communication between a variety of devices, data sources and data destinations. The OPC international interface standard is the key to open systems both now and in the future. Thanks to IndustrialDataBridge, OPC data exchange can already be supported. • WinCC supports access to variables, tag logging, alarm logging and user archive data. • Storage of process data in Office formats such as Excel or Access. Databases can also be integrated for the archiving of larger aggregates. • One of the features of IndustrialDataBridge is a Send/Receive interface supporting data transfer to SIMATIC S5/S7 stations or other Send/Receive-compatible devices. • IndustrialDataBridge enables SCADA and control systems from different vendors to be linked via the OPC interface. Communication via RFC1006 or Send/Receive is also supported. • SQL databases are available as data destinations for production data acquisition. Data can be transferred from the data source on an event-driven basis with the OPC module or sent directly from the PLC with the Send/Receive module. • Cyclic data archiving can be implemented via the OPC Data Access, WinAC ODK or Send/Receive data sources and the SQL database data destinations. On the database side, various transmission mechanisms are supported. • Individual control during runtime for each IndustrialDataBridge connection (start, stop, connect, and disconnect). • Integration of IndustrialDataBridge runtime control in WinCC screens if IDB is installed on a WinCC station. • Independent CSV files are created if a configurable number of entries is reached or the value of a WinCC tag changes. • Block transfer for databases through support for the operators "<" and ">" in the Select instruction. • Available providers (data sources) can be connected to any consumers (data destinations) (see table, below) New functions in Version 7.2: • Faster configuration due to new configuration interface • OPC XML DA Provider / Consumer (data exchange via the Internet using HTTP and SOAP) • Support for Asian languages (Simplified Chinese, Japanese) • Unicode support • Getting Started for data exchange between User Archive and Microsoft Access • For installation in combination with the WebNavigator Server, the IndustrialDataBridge can be controlled via the Internet 4/128 Siemens ST 80 / ST PC · 2013 The table below shows the possible data sources and destinations Provider (data sources) Consumer (data destinations) • MS Access 2003, 2007, 2010 • CSV, TXT • MS SQL server 2005, 2008, 2008 R2 • MS Access 2003, 2007, 2010 • MySQL ODBC 3, 5, 5.1, 5.5 • MySQL ODBC 3, 5, 5.1, 5.5 • Oracle 8i, 10g, 11g • Oracle 8i, 19g, 11g • OPC Data Access 3.0, OPC XML 1.0 • MS Excel • Send / Receive • MS SQL server • OPC Data Access Server (internal) • WinCC OLE DB V7.2 • OPC Data Access 3.0, OPC XML 1.0 • WinCC User Archive V7.2 • Send / Receive • WinCC User Archive V7.2 ■ Ordering data Order No. WinCC/IndustrialDataBridge V7.2, option for WinCC V7.2 For data exchange with databases and OPC servers; language versions: German, English, Chinese simplified, Japanese • with 128 tags • with 512 tags • with 2048 tags • with 10000 tags 6AV6371-1DX07-2AX0 6AV6371-1DX07-2BX0 6AV6371-1DX07-2CX0 6AV6371-1DX07-2DX0 V7.0 SP1, option for WinCC V7.0 SP3 For data exchange with databases and OPC servers; language versions: German/English • with 128 tags • with 512 tags • with 2048 tags • with 10000 tags 6AV6371-1DX07-0AX0 6AV6371-1DX07-0BX0 6AV6371-1DX07-0CX0 6AV6371-1DX07-0DX0 WinCC/IndustrialDataBridge Powerpack V7.2 • from 128 to 512 tags • from 512 to 2048 tags • from 2048 to 10000 tags 6AV6371-1DX07-2AB0 6AV6371-1DX07-2BC0 6AV6371-1DX07-2CD0 WinCC/IndustrialDataBridge Powerpack V7.0 • from 128 to 512 tags • from 512 to 2048 tags • from 2048 to 10000 tags 6AV6371-1DX07-0AB0 6AV6371-1DX07-0BC0 6AV6371-1DX07-0CD0 WinCC/IndustrialDataBridge upgrade • from V7.0 to V7.2 • from V6.x to V7.2 • from V6.x to V7.0 SP3 6AV6371-1DX07-2XX3 6AV6371-1DX07-2XX4 6AV6371-1DX07-0XX4 WinCC/IndustrialDataBridge V6.1, option for WinCC V6. 2 For data exchange with databases and OPC servers; language versions: English/German • with 128 tags • with 512 tags • with 2048 tags • with 10000 tags 6AV6371-1DX06-1AX0 6AV6371-1DX06-1BX0 6AV6371-1DX06-1CX0 6AV6371-1DX06-1DX0 WinCC/IndustrialDataBridge Powerpack V6.1 • from 128 to 512 tags • from 128 to 2048 tags • from 128 to 10000 tags • from 512 to 2048 tags • from 512 to 10000 tags • from 2048 to 10000 tags 6AV6371-1DX06-1AB0 6AV6371-1DX06-1AC0 6AV6371-1DX06-1AD0 6AV6371-1DX06-1BC0 6AV6371-1DX06-1BD0 6AV6371-1DX06-1CD0 © Siemens AG 2013 HMI Software SIMATIC WinCC options WinCC/IndustrialX ■ Overview ■ Benefits • Easy creation using configuration wizards • Quick entry due to the use of standards: ActiveX technology, creating with the aid of Visual Basic • Central creating and changing of object displays of the same type (typing) saves time and money • Configuring of intelligent, sector-specific objects (graphic illustration and logical processing) with know-how protection • Can be used in versatile ways: in WinCC screens and other Windows applications (e.g. Internet Explorer, Excel) Innovations of V7.0 Support of Visual Studio 2005 (.NET) ■ Application IndustrialX controls create standardized presentations and allow flexible customization to the requirements of a wide range of applications, e.g. applications in the chemical, glass or paper manufacturing industries. • WinCC/IndustrialX makes it easier to develop a solution for a visualization task by allowing customized objects to be standardized • A license must be installed on each development computer (current version of Visual Basic must be installed on the development computer) ■ Function • Configuring intelligent, industry-specific objects (graphic illustration and logical processing) with know-how protection • Automatic object supply with WinCC data structures (templates) • Creation of Web Navigator-compatible, customer-specific ActiveX components with active process data supply • Integration into WinCC via structure names ■ Ordering data Order No. WinCC/IndustrialX • V7.0; for WinCC V7.0 and V6.x 6AV6371-1EL17-0AX0 Note For WinCC V7.2, the WinCC/IndustrialX option is part of the WinCC/ODK option. Siemens ST 80 / ST PC · 2013 4/129 4 © Siemens AG 2013 HMI Software SIMATIC WinCC options WinCC/Open Development Kit (ODK) ■ Overview ■ Function WinCC/ODK (Open Development Kit) • WinCC option for utilization of the exposed programming interfaces that can be used to access data and functions of the WinCC configuration and WinCC runtime system • The interfaces are designed as "C-Application Programming Interface" (C-API) • Scope of delivery: - CD-ROM with examples - Voucher for a one-day intensive workshop ■ Benefits • Individual system expansions via an open standard programming language • Access to data and functions of the WinCC configuration and runtime system • Development of your own applications and add-ons for the WinCC basic system New in V7.0 • Support for Visual Studio 2005 (.NET) 4 New in V7.2 • UNICODE support • Support for Visual Studio 2008, 2012 4/130 Siemens ST 80 / ST PC · 2013 The API functions are configuration and runtime functions, and include: • MSRTCreateMsg: Creates a message • DMGetValue: Gets the value of a variable • PDLRTSetProp: Sets the object properties in a display They can be used in the following places: • within WinCC, for example in global scripts or as part of C actions in the Graphics Designer, • in Windows applications in the programming language C (the current version of Microsoft Visual C++ is necessary as a development environment for WinCC). ■ Ordering data WinCC/ODK • V7.2; for WinCC V7.x • V7.0; for WinCC V7.0 and V6.x Order No. 6AV6371-1CC07-2AX0 6AV6371-1CC07-0AX0 © Siemens AG 2013 HMI Software SIMATIC WinCC options WinCC/ProAgent ■ Overview ■ Ordering data Order No. SIMATIC WinCC/ProAgent • V7.2; for WinCC V7.2 • V7.0 SP3; for WinCC V7.0 SP3 SIMATIC WinCC/ProAgent Upgrade • to SIMATIC WinCC/ProAgent V7.2 • to SIMATIC WinCC/ProAgent V7.0 SP3 6AV6371-1DG07-2AX0 6AV6371-1DG07-0AX0 6AV6371-1DG07-2AX3 6AV6371-1DG07-0AX4 3B67B;;B 67(3 • Precise and rapid process fault diagnostics in plants and machines for SIMATIC S7 and SIMATIC HMI • Standardized diagnostics concept for various SIMATIC components • No further configuration for diagnostics functionality • Reduces PLC memory and processor usage 4 Note For further details, see "SIMATIC ProAgent process diagnostics software" Siemens ST 80 / ST PC · 2013 4/131 © Siemens AG 2013 HMI Software SIMATIC WinCC options WinCC/Redundancy • Option for SIMATIC WinCC, supporting the parallel operation of two interfaced WinCC single-user systems or process data servers for mutual monitoring • If one of the two server PCs or one of the two WinCC stations fails, the second one will take over control of the entire system. Once the failed server or station is restored to operation, the content of all the message and process value archives are copied to it. • One WinCC/Redundancy package is required for each redundant pair of servers. ■ Overview ~jj j shu ■ Benefits ~jj z wyvmpul{ G_ST80_XX_00082 wyvmpi|z ■ Function Normally, two WinCC stations or process data servers run in parallel. Each station has its own process connection and its own data archives. WinCC/Redundancy ensures automatic matching of system and user archive data. ~jj j 4 • Increased system availability with continuous data integrity • Automatic changeover of client in the event of failure of a server or failure of the communication to a server • Continuous operator control and visualization thanks to automatic client changeover to the intact server • Automatic updating of all archives in the background after rectification of the fault If one of the two server computers or WinCC stations fails, the second will take over the archiving of messages and process data, thereby ensuring seamless data integrity. In client/server mode, the clients are automatically switched from the failed server to the redundant partner. This ensures continuous plant visualization and operation on every operator station. shu ~jj z When the failed partner resumes operation, all process values, messages and data archived during the fail period are automatically matched with the partner. This process runs in the background and does not affect plant continuity. Once this is complete, two equivalent servers/stations will be available again. wyvmpul{ G_ST80_XX_00083 wyvmpi|z Communication with the SIMATIC S7 can also be configured with redundancy (an H Series SIMATIC S7 is required) by plugging in two communication modules and configuring two communication paths (S7-REDCONNECT software package). The use of failsafe H Series SIMATIC S7 can, if required, further increase availability at control level. ■ Ordering data ~jj j SIMATIC WinCC/Redundancy • Option for SIMATIC WinCC V7.2, Runtime software, single license for 2 installations • Option for SIMATIC WinCC V7.0, Runtime software, single license for 2 installations • Option for SIMATIC WinCC V6.2, Single license for 2 installations shu ~jj z wyvmpul{ G_ST80_XX_00084 wyvmpi|z 4/132 Siemens ST 80 / ST PC · 2013 Order No. 6AV6371-1CF07-2AX0 6AV6371-1CF07-0AX0 6AV6371-1CF06-2AX0 © Siemens AG 2013 HMI Software SIMATIC WinCC options WinCC/Server ■ Overview WinCC Client WinCC Client WinCC Client TERMINAL BUS TCP/IP PROCESS BUS G_ST80_XX_00005 WinCC Server • Option for SIMATIC WinCC, which permits the configuration of a powerful client/server system • One of the following operating systems must be available to install the option on the server: Windows Server 2003 (for V6) or Windows Server 2003 R2 (for V6.2 / V7.0 / V7.2) or Windows Server 2008 (for V7.0 with SP2 and higher or V7.2). When using Windows XP Professional and Windows 7 SP1, no more than 3 clients can be connected. • A number of coordinated HMI stations can be operated in a single group with networked automation systems • Client/server solution: - One server can supply up to 32 connected clients with process and archive data, messages, images and reports - Depending on the size of the plant, up to 12 servers (or up to 18 in version 7.2 or higher) can be used. - 32 clients (max. 12 or 18 redundant WinCC servers) possible per system • Requirement: Network connection (TCP/IP) between the server PC and the connected clients. 1) • One license is required for each server. 1) One of the following operating systems is installed on one WinCC server: Windows Server 2003, Windows Server 2003 R2 or Windows Server 2008. Max. 3 clients with Windows XP Professional and Windows 7 SP1. ■ Benefits • Plant-wide scalability from the single-user system to the client/server solution • Significantly higher quantity framework, relieving the individual servers and better performance due to distributing the complete application or tasks over several servers • Low-cost configuration on the client is possible (the minimum RC license is sufficient) 4 ■ Application In a complex plant, WinCC can also be configured as a distributed system according to requirements: • Functional distribution (e.g. message servers, archive servers, etc.) or • Distribution according to the physical plant structure (e.g. body-in-white, paintshop, etc.) ■ Function Each client can access more than one server at a time. Clients can also be used for configuration on the server. A configuration of WinCC clients as a central Web server - as a distributed system if required - with an overview of all server projects in the system is also possible. For WinCC clients, only the smallest runtime license RT128 is required. In order to also configure on WinCC clients, the smallest complete license RC128 is required. Remote configuration is possible if WinCC clients without their own project (Uniclients) on the server project are configured. This makes it possible to configure inexpensive operator and configuration stations in a network. ■ Ordering data Order No. SIMATIC WinCC/Server • Option for SIMATIC WinCC V7.2, Runtime software, single license • Option for SIMATIC WinCC V7.0, Runtime software, single license • Option for SIMATIC WinCC V6.2, Single license 6AV6371-1CA07-2AX0 6AV6371-1CA07-0AX0 6AV6371-1CA06-2AX0 Siemens ST 80 / ST PC · 2013 4/133 © Siemens AG 2013 HMI Software SIMATIC WinCC options WinCC/TeleControl ■ Overview WinCC/TeleControl for WinCC V7.0 SP2 supports connection to outlying stations (Remote Terminal Units = RTUs) via telecontrol protocols. ■ Benefits WinCC/TeleControl for WinCC V7.0 SP2 cannot only integrate newly configured RTUs, it can also integrate units which already exist in outlying areas by means of DNP3 or IEC 870-5-101/104 drivers. For communication with the outstations, WinCC/TeleControl for WinCC V7.0 SP2 uses the SINAUT ST7 and DNP3 protocols (both via serial and TCP/IP communication connections) as well as IEC 870-5-101 (serial) and IEC 870-5-104 (Ethernet TCP/IP). The serial RTU link is possible via the following components, which can be connected directly via WinCC (single station or server): • SINAUT TIM communication modules (SINAUT ST7 telecontrol protocol) • TCP/IP serial converter (telecontrol protocols DNP3, Modbus (not released for WinCC TC), IEC 870-5-101) Equipment from MOXA or Lantronix, for example, can be used as TCP/IP serial converters. 4 By means of Ethernet TCP/IP, the RTUs can be connected directly or via TCP/IP WAN routers to the SIMATIC WinCC system bus (SINAUT ST7, DNP3, IEC 870-5-104 telecontrol protocols). When using the SINAUT ST7 telecontrol protocol, the SINAUT TIM communication module can be used in addition to the TCP/IP WAN router or as an alternative. ■ Application Telecontrol communication over the wide area network is largely determined by the communication infrastructure which already exists. Various transmission media such as dedicated line, analog or digital telephone networks, wireless networks (GSM or private), DSL or GPRS can also be combined with each other. SINAUT ST7 telecontrol protocol Detailed information for implementing telecontrol applications with the SINAUT ST 7 telecontrol protocol via the Industry Mall. IEC 870-5-101/-104 telecontrol protocols Detailed information for implementing telecontrol applications with the IEC 870-5-101/-104 telecontrol protocols via the Industry Mall. DNP3 telecontrol protocol WinCC/TeleControl for WinCC V7.0 SP2 also supports the DNP3 telecontrol protocol. Widely distributed outstations (RTUs) can be controlled and monitored with the DNP3 telecontrol protocol via serial or Ethernet TCP/IP communication links by means of the telecontrol center in SIMATIC WinCC. The control center integrated with SIMATIC WinCC TeleControl into the SCADA system is the master during telecontrol communication. The slaves are represented by the outstations. SIMATIC S7-300/ S7-300F and S7-400/S7-400F/S7-400H/S7-400FH controllers as well as third-party RTUs can be used as outstations. 4/134 Siemens ST 80 / ST PC · 2013 Further hardware and software components round off the range of products: • TIM communication modules • TCP/IP converters – serial and MD modem modules • GSM/GPRS components • TCP/IP routers and switches • SCALANCE S612 and S613 security modules • Dedicated-line accessories • Connecting cables and cables • Engineering package for configuration of DNP3 data objects, stations, networks and connections as well as for diagnostics In order to implement telecontrol networks, basic topologies including point-to-point, multi-point, star and ring can be configured using classic or TCP/IP-based media. These can be combined flexibly independent from existing infrastructure. Classic WAN media: • Dedicated line via modem, e.g. SINAUT MD2 • Private wireless networks • Analog telephone network • Digital ISDN network • Mobile radio network GSM TCP/IP-based WAN media: • Ethernet networks, e.g. SCALANCE X with fiber-optic cables • Industrial Wireless LAN with SCALANCE W • Public networks and the Internet using DSL and/or GPRS ■ Function Special characteristics of DNP3 communication • Change-driven data transmission - Change-driven transmission of process data between RTU and control center - Signaling of RTU, control center or connection failure - Automatic data updating for all communication partners involved following troubleshooting and following the startup of the RTU or control center • Chronological processing of process data - Time tagging of all data frames at the place of origin allows process data to be archived by the process control system in the correct chronological order - The time of the DNP3 stations in the WAN can be synchronized via SIMATIC WinCC (including summertime/wintertime switchover) • Local data storage - The TIM communication module can temporarily store (for several hours or even days) message frames should the connection or the communication partner fail - Intermediate storage of message frames of lower priority in the case of priority-controlled data transmission (with dial-up networks or quantity-dependent data transmission costs) Operating modes The DNP3 telecontrol protocol supports the following operating modes: • Polling • Polling with time slot procedure • Multi-master polling with time slot procedure • Spontaneous mode in dial-up networks • Spontaneous mode in the TCP/IP-based WAN © Siemens AG 2013 HMI Software SIMATIC WinCC options WinCC/TeleControl ■ Integration Integration of WinCC/TeleControl for WinCC V7.0 SP2 into the WinCC SCADA system offers particular advantages for the water and waste water sectors, as well as oil and gas sectors, especially in the case of the following types of plant: • Freshwater treatment and distribution • Wastewater treatment plants • Oil and gas pipelines and water pipes • Oil and gas drilling fields and the associated treatment plants In these types of plant, remote outstations such as pumping stations, valve stations or automated stations for wellheads must be integrated. Through the support of communication protocols for RTUs such as SINAUT ST7, WinCC/TeleControl for WinCC V7.0 SP2 supports the following advanced communication concepts: • Reduction in the transferred data volume by means of eventcontrolled communication mechanisms for alarm and measured value information. • Time-synchronization of RTUs and correct time stamping of all data in the RTU. • Tolerance of lower bandwidth, high latency or lack of reliability of communication lines • Prevention of data loss due to communications failure through data backup in the RTU • Support of communication media with serial interface (dedicated lines, dial-up connections over analog telephone lines and ISDN lines), various radio devices (standard, spread spectrum modulation), microwave and GSM • Support for TCP/IP-based WANs (Wide Area Networks) such as DSL, GPRS or Ethernet radio networks • Support for redundant communication connections • Expanded communication diagnostics functions for RTU communication links • Remote programming of RTUs • Support for different communication topologies – point-to-point, multidrop (multistation mode) and hierarchic network structures • High quality server redundancy scheme without data loss in the case of server failure Through the support of communication protocols for RTUs such as IEC 60870-5 and DNP3, SIMATIC TeleControl for WinCC V7.0 SP2 supports the following advanced communication concepts: • Reduction in the transferred data volume by means of eventcontrolled communication mechanisms for alarm and measured value information. • Time synchronization of RTUs and correct time stamping of all data in the RTU. • Tolerance of lower bandwidth, high latency or lack of reliability of communication lines • Prevention of data loss due to communications failure through data backup in the RTU (not all non-Siemens RTUs support this) • Support of communication media with serial interface (dedicated lines, dial-up connections over analog telephone lines and ISDN lines), various radio devices (standard, spread spectrum modulation), microwave and GSM • Support for TCP/IP-based WANs (Wide Area Networks) such as DSL, GPRS or Ethernet radio networks • Support for redundant communication connections • Expanded communication diagnostics functions for RTU communication links • Remote programming of RTUs • Support for different communication topologies – Point-topoint, multidrop (multistation mode) and hierarchic network structures • High quality server redundancy scheme without data loss in the case of server failure Outstations/remote terminal units WinCC/TeleControl for WinCC V7.0 SP2 supports the following preferred outstations for local distributed automation: • Controller integrated into ET 200S (IEC 870-5-101/104 telecontrol protocols); for cost-sensitive applications, up to approx. 30 I/O signals or approx. 200 data points • S7-300/S7-300F controller (SINAUT ST7, DNP3, IEC 870-5-101/104 telecontrol protocols); for extremely flexible configuration, up to 100 I/O signals or approx. 2000 data points • S7-400/S7-400F controller (SINAUT ST7, DNP3, IEC 870-5-101/104 telecontrol protocols); up to 500 I/O signals or approx. 5000 data points • S7-400/S7-400F redundant controller (IEC 870-5-101/104 and DNP3 telecontrol protocols); up to 500 I/O signals or approx. 5000 data points • Third-party station with the IEC 870-5-101/104 and DNP3 telecontrol protocols (depending on type of station) Siemens ST 80 / ST PC · 2013 4/135 4 © Siemens AG 2013 HMI Software SIMATIC WinCC options WinCC/TeleControl ■ Integration (continued) The following table provides an overview of the current options for connecting to these outstations: Spectrum of outstations and integration versions Telecontrol protocol SINAUT ST 7 IEC 870-5-01 IEC 870-5-04 Type of communication Serial Ethernet TCP/IP Serial Ethernet TCP/IP Serial Ethernet TCP/IP Interface TIM 4R-IE TCP/IP WAN router or/and TIM 4R-IE TCP/IP serial converter TCP/IP WAN router TCP/IP serial converter TCP/IP WAN router ET 200S with integr. CPU (corresponding to S7-314) - - - - IM 151-7 CPU or IM 151-8 PN/DP CPU as well as 1 SI module + SIPLUS RIC library IM 151-8 PN/DP CPU + SIPLUS RIC library S7-300/S7-300F TIM 3V-IE TIM 3V-IE TIM 3V-IE DNP3 TIM 3V-IE DNP3 CP 341 + SIPLUS RIC library CP 343 + IEC on S7 or integr. PN interface + SIPLUS RIC library S7-400/S7-400F TIM 4R-IE TIM 4R-IE TIM 4R-IE DNP3 TIM 4R-IE DNP3 CP 441 + SIPLUS RIC library CP 443 + SIPLUS RIC library or integr. PN interface + SIPLUS RIC library S7-400H/ S7-400FH - - TIM 4R-IE DNP3 TIM 4R-IE DNP3 ET 200M + 2 x CP 341 + SIPLUS RIC library CP 443 + SIPLUS RIC library Third-party station - - Depends on type of station Depends on type of station Dial-up lines • - • - - - Dedicated line and radio networks • • • • • • Master/slave • • • • • • Peer-to-peer • • - - • • Mesh networks • • • • • • Time tagging in RTU • • • • • • RTU time synchronization • • • • • RTU/interface 4 DNP3 • 1) • 1) Data buffering in RTU • • • • • Routing with SIMATIC PDM • • - - - • International standard - - • • • • 1) Data buffering is limited to two SIMATIC S7 data blocks. Depending on the SIMATIC CPU, this corresponds to approx. 800 to 3200 buffered frames. 4/136 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 HMI Software SIMATIC WinCC options WinCC/TeleControl ■ Ordering data SIMATIC TeleControl 7.0 SP2 for WinCC Basic Engineering Order No. 6DL5000-7AA07-0XA5 Software package with SIMATIC TeleControl for WinCC 7.0 SP2 Engineering Software, 2 languages (English, German), executable with Windows XP Professional/Server 2003, Floating License for one user; electronic documentation on CD/DVD, 2 languages (English, German) Type of delivery: License key memory stick, Certificate of License incl. terms and conditions, SIMATIC WinCC Data Medium Package V7.0 + SP2 and CD "WinCC TeleControl Option V7.0 + SP2" SIMATIC TeleControl 7.0 SP2 for Server Runtime (6 stations) 6DL5002-7AA07-0XA0 Software package with SIMATIC TeleControl for WinCC 7.0 SP2 Runtime Software, 2 languages (English, German), executable with Windows Server 2003, Single License for one user; electronic documentation on CD/DVD, 2 languages (English, German) Type of delivery: License key memory stick, Certificate of License incl. Terms and Conditions, SIMATIC WinCC Data Medium Package V7.0 + SP2 and CD "WinCC TeleControl Option V7.0 + SP2" 6DL5101-8AX00-0XB0 Runtime license for one WinCC Single Station or one WinCC server, Single License for 1 installation Requirement: Software SIMATIC TeleControl 7.0 SP2 for WinCC Server Runtime (6, 12, 256 stations) Type of delivery: License key memory stick, Certificate of License incl. terms and conditions TeleControl DNP3 Driver 6DL5002-7AB07-0XA0 Software package with SIMATIC TeleControl for WinCC 7.0 SP2 Runtime software, 2 languages (English, German), executable with Windows Server 2003, single license for one user; electronic documentation on CD/DVD, 2 languages (English, German) Type of delivery: License key memory stick, Certificate of License incl. terms and conditions, SIMATIC WinCC Data Medium Package V7.0 + SP2 and CD "WinCC TeleControl Option V7.0 + SP2" SIMATIC TeleControl 7.0 SP2 for Server Runtime (256 stations) 6DL5002-7AF07-0XA0 Driver software for telecontrol protocols TeleControl SINAUT Driver Software package with SIMATIC TeleControl for WinCC 7.0 SP2 Runtime Software, 2 languages (English, German), executable with Windows Server 2003, Single License for one user; electronic documentation on CD/DVD, 2 languages (English, German) Type of delivery: License key memory stick, Certificate of License incl. terms and conditions, SIMATIC WinCC Data Medium Package V7.0 + SP2 and CD "WinCC TeleControl Option V7.0 + SP2" SIMATIC TeleControl 7.0 SP2 for Server Runtime (12 stations) Order No. SIMATIC TeleControl 7.0 SP2 for Server Runtime (unlimited stations) 6DL5101-8EX00-0XB0 Runtime license for one WinCC Single Station or one WinCC server, single license for 1 installation Requirement: Software SIMATIC TeleControl 7.0 SP2 for WinCC Server Runtime (6, 12, 256 stations) Type of delivery: License key memory stick, Certificate of License incl. terms and conditions TeleControl IEC 870-5-101/-104 Driver 6DL5002-7AE07-0XA0 Software package with SIMATIC TeleControl for WinCC 7.0 SP2 Runtime software, 2 languages (English, German), executable with Windows Server 2003, single license for one user; electronic documentation on CD/DVD, 2 languages (English, German) Type of delivery: License key memory stick, Certificate of License incl. terms and conditions, SIMATIC WinCC Data Medium Package V7.0 + SP2 and CD "WinCC TeleControl Option V7.0 + SP2" 4 6DL5101-8CX00-0XB0 Runtime license for one WinCC Single Station or one WinCC server, single license for 1 installation Requirement: Software SIMATIC TeleControl 7.0 SP2 for WinCC Server Runtime (6, 12, 256 stations) Type of delivery: License key memory stick, Certificate of License incl. terms and conditions ■ More information For an overview of the complete performance spectrum on the Internet, visit: Service & Support: http://www.siemens.com/automation/csi_en_WW/service (international) Technical Support (hotline) for Automation & Drives: http://www.siemens.com/automation/csi_en_WW/ support_request (international) Siemens ST 80 / ST PC · 2013 4/137 © Siemens AG 2013 HMI Software SIMATIC WinCC options WinCC/User Archives ■ Overview ■ Function • Input of parameter sets (e.g. operating parameters of a machine) in WinCC, storage of the sets in the user archive, and forwarding to the automation level • Continuous acquisition of production parameters by the automation system and forwarding of the parameters to WinCC at the end of the shift • Acquisition of batch data • Specification of production parameters • Management of warehousing data WinCC user archives are created and assigned data in a userfriendly way using a dedicated editor. Special ActiveX controls are used for displaying data from the user archives at runtime. Data sets and fields from user archives are linked to the process via direct tag linking. 4 • Option for SIMATIC WinCC for managing data sets in user archives that contain related data. • WinCC and its automation partners (e.g. a SIMATIC S7 controller) write these data sets and exchange them if required. • A license is only required for the server (or single-user system). The WinCC/User Archives option can also be used in the context of the WinCC/Web Navigator (see also WinCC/Web Navigator option). WinCC provides functions for free organization of the data storage in the user archives that affect archives, data sets and fields. Archives can thus be generated, opened, closed, or reset, and data sets or field contents can be read, written or overwritten. Sequence archives can accommodate batch data, shift production data, or also product quality data, and meet legal obligations for verification thanks to gap-free recording. ■ Ordering data ■ Benefits • Storing and managing of any user data in data sets • Flexible display using ActiveX controls • Simple linking of data set fields to the process via direct tag linking • Import/export functions for further processing with other tools (e.g. MS Excel) 4/138 Import and export functions support read-in/out of data via external applications (e.g. MS Excel). Freely selectable filter criteria allow clear representation of data sets. Siemens ST 80 / ST PC · 2013 SIMATIC WinCC/User Archives • Option for SIMATIC WinCC V7.2, Runtime software, single license • Option for SIMATIC WinCC V7.0, Runtime software, single license • Option for SIMATIC WinCC V6.2, Single license Order No. 6AV6371-1CB07-2AX0 6AV6371-1CB07-0AX0 6AV6371-1CB06-2AX0 © Siemens AG 2013 HMI Software SIMATIC WinCC options WinCC/Web Navigator ■ Overview WinCC Web client WinCC DataMonitor Internet WinCC SCADA client + Web server WinCC SCADA clients WinCC Web client WinCC DataMonitor LAN WinCC server (max. 18) 4 PROFINET G_ST80_XX_00021 PROFIBUS • Option for SIMATIC WinCC for operator control and monitoring of plants via the Internet, in-house intranet or LAN • Configuration from: - a Web server with the SIMATIC WinCC software as a singleuser, client or server version and a Web client that enables operator control and monitoring of a current WinCC project via an Internet browser with ActiveX support. The WinCC basic system does not have to be installed on the client computer. It is also possible to use the Web client without Microsoft Internet Explorer. • Licensing: - A license is required in order to use the Web server. - Licenses are available for access to the Web server by 1, 3, 5, 10, 25, 50, 100 or 150 clients. - Low-priced WebNavigator diagnostics licenses are available for the remote diagnostics via multiple, distributed Web servers. Siemens ST 80 / ST PC · 2013 4/139 © Siemens AG 2013 HMI Software SIMATIC WinCC options WinCC/Web Navigator ■ Overview (continued) 4 Highlights: • Installation of the Web server - in distributed systems - also on a WinCC Client; - Access to as many as 18 subordinate WinCC stations (servers) possible - Web clients offer common views of data on various WinCC Servers - If you are using WinCC/Redundancy, the Web clients will also transfer via the subordinate WinCC servers (requires WebNavigator server to be installed on the WinCC Client (RT128) ) - Separating the Web functionality from the WinCC data servers makes the overall system safer and more scalable in respect of load. Integrated user management with WinCC: The configured WinCC operator authorizations are taken into account on the Web client. • Access to WebNavigator server from the WebNavigator TIA Portal series of products. • Access to user archives. • VB scripts are supported in the same way as the new objects and RT functions in WinCC V7.x. • User-friendly services and tools for distributing customized objects (controls, files) to Web clients can be supplied for use as an integration platform. These components can then also be integrated into cross-Web/Server navigation. • Distribution of load across a number of Web servers in order to run several hundred Web clients in a single system; Web clients are distributed across Web servers automatically. • Version 7.2 supports Microsoft Internet Explorer Version 8.0 and 9.0, including tabbed browsing. A new license is not required for separate tabs. • With the WinCC Web Viewer, the process screens can be displayed on the Web client independently of the Internet Explorer. Settings for the client are made on the client itself. • The WinCC Web Viewer can also be used in conjunction with the Microsoft Terminal Service. • From version 7 on, the WebNavigator can also be operated in "view only" mode and is thus used as tool for operating and navigating only via WinCC screens by means of the Internet Explorer. • The cursor for View only mode can be selected according to individual requirements. • Web server logins and logouts are recorded in the alarm and audit archive. • There is a gadget available for the Windows 7 operating system in which selected WinCC process screens can be displayed. The gadget does not require any additional WebNavigator license. The WebNavigator server can be selected direct using the gadget. • Security is increased by adjustable automatic logout. If an automatic logout is to take place, an absolute or inactive time period can be set. • Runtime in the Web client can be terminated by means of scripting. 4/140 Siemens ST 80 / ST PC · 2013 ■ Benefits • Operator control and monitoring across long distances and on different platforms (PC, local panel, mobile PDA) • Large configurations with up to 150 operator stations • Fast updating rates thanks to event-driven communication • Optimally tailored clients for operating and monitoring, analysis, service and diagnostics • Acceptance of configuration data for the Web, generally without changes • Minimum maintenance costs thanks to centralized software administration • High security standards and availability - Increased security due to separation of WinCC server and Web server (Web server in secure environment) - Support for commonly used security mechanisms (routers, firewalls, proxy servers) - Access authorization and user administration New in V7.2 • New license stages for 1, 5, 100, 150 clients and associated powerpacks 1/3, 3/5, 50/100, 100/150 • Unicode support • PDL password protection with WebNavigator PDLPad • Login / logout / register: • Log user in/out on the WebNavigator client • Manual logout in the Internet Explorer by means of ODK C-Script (PWRTLogout function) • Configurable logout/login in the WinCC RT Viewer ■ Application In addition to the typical use of the Web Navigator in WANs (Wide Area Network), the Web Navigator is also suitable for solving especially low-cost applications. This especially includes applications that have a pronounced distributed structure (water/wastewater, oil & gas), or in which access to process information is only sporadic (building management). The Web Navigator also permits vertical integration, i.e. a networked IT landscape with integrated data flow between the planning and operating levels within a company. Only a standard browser is required for direct access to current process information. The Web Server can have its own dedicated direct process connection. An alternative is coupling via OPC or the use of a remote Web Server to a WinCC Client. This simultaneously increases security and reduces the communication load of the plant. In addition to the Standard Web Navigator licensing there is the so-called Diagnostics Client, with identical functions in principle, but which is especially suitable for the following applications: • Remote diagnostics/operation of several unmanned WinCC stations. • Central control rooms which monitor multiple Web Servers on one user interface. • Power Users that always require guaranteed access to the server regardless of the number of users already logged on to the server. © Siemens AG 2013 HMI Software SIMATIC WinCC options WinCC/Web Navigator ■ Design Licenses for the Web Navigator The Web Navigator Client software can be installed as many times as required without the need for a license. • Server-based licensing; a license is required in order to use the Web Navigator Server. Licenses are available for simultaneous access to the Web server by 1, 3, 5, 10, 25, 50, 100 or 150 clients. • Diagnostics client licensing; for optimum-cost access by one or a small number of Web Navigator Clients to numerous Web servers (e.g., for the purpose of diagnostics). This client license provides guaranteed access to Web servers at any time. In respect of function there is no difference compared with regular Web Navigator Clients and the two can be mixed. Web Navigator Clients can: • Access a number of different web servers or • Access data on a number of higher-level WinCC stations simultaneously via a remote Web server ■ Function The Web Configurator (Wizard) makes setting up and configuring a Web Navigator Server very easy. WinCC process screens to be visualized via the Internet are created as usual using WinCC Graphics Designer. Under normal circumstances the project can be worked on locally without modification. The Web Publishing Wizard optimizes the screens for transmission and display on the Internet. A standard browser is all that is required to display WinCC process screens on the Web Client. The MS Internet Explorer is used depending on the Web Navigator version used (tip: start the Internet Explorer in fullscreen mode with the start parameter "-k"). The operator on the Web Client is integrated in the central WinCC user administration and can operate and monitor the system according to the configured access rights. The Web Navigator supports all standard security mechanisms that can be used for applications on the Internet, e.g. routers, firewalls and proxy servers. On the server side, only one Web Navigator Diagnostics Server license or, alternatively, one Standard Web Navigator license is required. Alternatively, a number of Web Navigator Servers with the same WinCC project can be combined to create a "server farm". This means that it is possible for several hundred Web clients to have access to the same database. The service ensures that the clients accessing are distributed evenly across all servers. If a server fails the Web client is automatically forwarded to the next available server. 4 In order to use this functionality you will need to install a Web Load Balancing license on the Web servers involved. Each Load Balance package contains 2 licenses. An inexpensive expansion option for Web Load Balancing is available for redundant WinCC stations on which the Web Navigator is also installed. For this purpose, you need to install a Web Load Balancing Step Up license on the web servers involved. Each Step Up package contains 2 licenses. Thin Client solutions The Web Navigator can also run under Windows Server 2003 or Windows Server 2008 terminal services. A Windows Server 2003 or Windows Server 2008 (or higher) operating system is required. This makes it possible to connect SIMATIC Thin Clients as visualization stations to WinCC, for example. For this purpose, the Windows terminal services must be installed on the PC on which the Web client is installed. A Windows Server 2003 or Windows Server 2008 (or higher) operating system is required. Up to 25 ThinClients can be connected to one terminal server. Applications: • Mobile devices • Handhelds • Rugged on-site visualizations Hybrid configuration Web Navigator and DataMonitor clients can be mixed in a single system. Siemens ST 80 / ST PC · 2013 4/141 © Siemens AG 2013 HMI Software SIMATIC WinCC options WinCC/Web Navigator ■ Ordering data Order No. WinCC/Web Navigator 4 V7.2; for WinCC V7.2 • 1 client license • 3 client licenses • 5 client licenses • 10 client licenses • 25 client licenses • 50 client licenses • 100 client licenses • 150 client licenses 6AV6371-1DH07-2LX0 6AV6371-1DH07-2AX0 6AV6371-1DH07-2MX0 6AV6371-1DH07-2BX0 6AV6371-1DH07-2CX0 6AV6371-1DH07-2DX0 6AV6371-1DH07-2GX0 6AV6371-1DH07-2HX0 WinCC/Web Navigator Powerpacks V7.2 • From 1 to 3 clients • From 3 to 5 clients • From 5 to 10 clients • From 10 to 25 clients • From 25 to 50 clients • From 50 to 100 clients • From 100 to 150 clients 6AV6371-1DH07-2LA0 6AV6371-1DH07-2AM0 6AV6371-1DH07-2MB0 6AV6371-1DH07-2BC0 6AV6371-1DH07-2CD0 6AV9681-1DH07-2DG0 6AV9681-1DH07-2GH0 WinCC/Web Navigator Diagnostics Client • for WinCC V7.2 6AV6371-1DH07-2EX0 WinCC/Web Navigator Diagnostics Server • for WinCC V7.2 6AV6371-1DH07-2FX0 WinCC/Web Navigator upgrade V6.0 to V7.0; V6.2 to V7.0; V6.2 to V7.2 • For 3, 10, 25, 50 clients • Diagnostics server and diagnostics client • Load Balancing WinCC/Web Load Balancing V7.2 • Load Balancing • Load Balancing Step Up 4/142 Included in corresponding WinCC upgrade 6AV6371-1DH07-2JX0 6AV6371-1DH07-2FJ0 Siemens ST 80 / ST PC · 2013 Order No. V7.0; for WinCC V7.0, WinCC V7.0 SP1/SP2/SP3 and WinCC V7.0 SP1/SP2/SP3 ASIA • Base Pack (3 client licenses) • 10 client licenses • 25 client licenses • 50 client licenses 6AV6371-1DH07-0AX0 6AV6371-1DH07-0BX0 6AV6371-1DH07-0CX0 6AV6371-1DH07-0DX0 WinCC/Web Navigator Powerpacks V7.0 • From 3 to 10 clients • From 10 to 25 clients • From 25 to 50 clients 6AV6371-1DH07-0AB0 6AV6371-1DH07-0BC0 6AV6371-1DH07-0CD0 WinCC/Web Navigator Diagnostics Client • for WinCC V7.0 6AV6371-1DH07-0EX0 WinCC/Web Navigator Diagnostics Server • for WinCC V7.0 6AV6371-1DH07-0FX0 WinCC/Web Navigator upgrade V6.0 to V7.0 • For 3 clients • For 10 clients • For 25 clients • For 50 clients 6AV6371-1DH07-0AX4 6AV6371-1DH07-0BX4 6AV6371-1DH07-0CX4 6AV6371-1DH07-0DX4 V6.2 to V7.0 • For 3 clients • For 10 clients • For 25 clients • For 50 clients 6AV6371-1DH07-0AX3 6AV6371-1DH07-0BX3 6AV6371-1DH07-0CX3 6AV6371-1DH07-0DX3 V6.x to V7.0 • For Web Navigator Diagnostics Client • For Web Navigator Diagnostics Server WinCC/Web Load Balancing V7.0 • Load Balancing • Load Balancing Step Up 6AV6371-1DH07-0EX4 6AV6371-1DH07-0FX4 6AV6371-1DH07-0JX0 6AV6371-1DH07-0FJ0 © Siemens AG 2013 HMI Software SIMATIC WinCC options WinCC/Web Navigator ■ Ordering data Order No. WinCC/Web Navigator System requirements – Web server V6.2 SP3; for WinCC V6.2 SP3 • Base Pack (3 client licenses) • 10 client licenses • 25 client licenses • 50 client licenses 6AV6371-1DH06-2AX0 6AV6371-1DH06-2BX0 6AV6371-1DH06-2CX0 6AV6371-1DH06-2DX0 V6.2 SP3 ASIA; for WinCC V6.2 SP3 ASIA • Base Pack (3 client licenses) • 10 client licenses • 25 client licenses • 50 client licenses 6AV6371-1DH06-2AV0 6AV6371-1DH06-2BV0 6AV6371-1DH06-2CV0 6AV6371-1DH06-2DV0 WinCC/Web Navigator Powerpacks • V6.2 (for ASIA variants as well) • From 3 to 10 clients • From 10 to 25 clients • From 25 to 50 clients 6AV6371-1DH06-2AB0 6AV6371-1DH06-2BC0 6AV6371-1DH06-2CD0 WinCC/Web Navigator Diagnostics Client • for WinCC V6.2 SP3 • for WinCC V6.2 SP3 ASIA 6AV6371-1DH06-2EX0 6AV6371-1DH06-2EV0 WinCC/Web Navigator Diagnostics Server • for WinCC V6.2 SP3 • for WinCC V6.2 SP3 ASIA 6AV6371-1DH06-2FX0 6AV6371-1DH06-2FV0 WinCC/Web Navigator upgrade V1.x to V6.2 SP3 • For 3 clients • For 10 clients • For 25 clients • For 50 clients V6.x to V6.2 SP3 • For 3, 10, 25, 50 clients 1) • For Web Navigator Diagnostics Client • For Web Navigator Diagnostics Server V6.x ASIA to V6.2 SP3 ASIA • For 3, 10, 25, 50 clients 1) WinCC/Web Load Balancing V6.2 SP3 • Web Load Balancing (2 licenses) • Web Load Balancing Step Up (2 licenses) 1) ■ More information 6AV6371-1DH06-2AX4 6AV6371-1DH06-2BX4 6AV6371-1DH06-2CX4 6AV6371-1DH06-2DX4 6AV6371-1DH06-2XX3 6AV6371-1DH06-2EX3 6AV6371-1DH06-2FX3 6AV6371-1DH06-2XV3 6AV6371-1DH06-2JX0 6AV6371-1DH06-2FJ0 Including upgrade for diagnostics client, diagnostics server, Web Load Balancing and Web Load Balancing Step Up. For WinCC/Web Navigator V7.2 • Windows 7 SP1 (32- and 64-bit) Business, Enterprise and Ultimate (max. 3 clients) • Windows XP Professional Service Pack 3 (max. 3 clients) • Windows Server 2003 SP2 • Windows Server 2008 SP2 32-bit • Windows Server 2008 R2 SP1 64-bit • Internet Explorer V7.0, V8.0 and V9.0 • Microsoft SQL Server 2008 R2 SP1, 32-bit (included in the WinCC product delivery) For WinCC/Web Navigator V7.0 • Windows 7 (32-bit) Business, Enterprise and Ultimate (max. 3 clients) • Windows XP Professional Service Pack 3 (max. 3 clients) • Windows Server 2003 SP2 and Windows Server 2003 R2 SP2 • Windows Server 2008 SP2 • Internet Explorer V6.0 SP1 or SP2 as well as Internet Explorer V7.0. • Microsoft SQL Server 2005 SP2 (scope of supply of WinCC) • WinCC Basic System V7.0 SP2 For WinCC/Web Navigator V6.2 SP3 • Windows 2000 Professional Service Pack 4 (max. 3 clients) • Windows XP Professional or Service Pack 3 (max. 3 clients) • Windows Server 2003 SP2 or Windows Server 2003 R2 SP2 • Internet Explorer 6.0 SP1, SP2 or 7.0 (without multitabbing) • Microsoft SQL Server 2005 SP1 (scope of supply of WinCC) • WinCC basic system V6.2 SP3 System requirements –Web client For WinCC/Web Navigator V7.0 • Internet Explorer V6.0 SP1 or SP2 as well as Internet Explorer V7.0 For WinCC/Web Navigator V6.2 SP3 • Internet Explorer 6.0 SP1, SP2 or 7.0 (without multitabbing) WinCC Web Navigator V6.2 SP3 ASIA (requires SIMATIC WinCC V6.2 SP3 ASIA) The functions included in this version differ from the standard version of WinCC/Web Navigator V6.2 SP3 as follows: • This version does not allow an Asian Web Navigator client to access a non-Asian server and vice versa. Siemens ST 80 / ST PC · 2013 4/143 4 © Siemens AG 2013 HMI Software WinCC add-ons und partner management WinCC add-ons and partner management Premium Add-ons for Connectivity: • PM OPEN IMPORT system software for importing WinCC flexible archives into the WinCC system. • PM OPEN EXPORT system software for exporting WinCC data to local storage media or storage media released in the network. • PM OPEN TCP/IP system software permits bidirectional exchange of WinCC data (tags, messages) with one or more computers that communicate using the TCP/IP protocol. • Historian CONNECT ALARM system software permits importing of messages and alarms from WinCC and WinCC flexible into the SIMATIC IT Historian. • TOP Server/TOP Server UCON expands OPC-based the connection capability for WinCC & WinCC flexible Advanced (PC based runtime) ■ Overview C WinCis-SW Bas C, RT R C WinCtion Op C WinCd-on Ad C WinCtion Op C WinCd-on Ad 4 G_ST80_XX_00175 C WinCtion Op C WinCd-on Ad WinCC Premium Add-ons – Solutions for all sectors and technologies The basic system is designed to be independent of any specific technology or industrial sector, to be modular and flexibly expandable and to permit not only simple single-user applications in machine construction, but also complex multi-user solutions or even distributed systems with several servers and clients in plant engineering. WinCC Premium Add-ons are supplementary products that have been created by competent partners working in the specifc sectors and technologies and represent interesting expansions for WinCC. WinCC Premium Add-ons are not IA (Siemens Industry Automation) products, but the products of partners who are committed to complying with certain quality features and boundary conditions. The Premium Add-ons are checked, for example, in the Siemens Test Center for their compatibility with the basic WinCC system and supported in the first instance by the central Hotline. As they are important application- and sector-specific add-on products for SIMATIC WinCC, they are marketed jointly by Siemens and the respective add-on suppliers. The WinCC Premium Add-on products can be found on the Internet (see Further Information) and in the "Online WinCC Premium Add-on Catalog". 4/144 Siemens ST 80 / ST PC · 2013 Premium Add-on for process management: • PM CONTROL system software is a recipe system for user-friendly generation and modification of recipes. • PM QUALITY system software is an archive system for the administration of job and batchrelated production and process data. Premium Add-on for sector products: • Library SENTRON PAC3200 for SIMATIC WinCC permits seamless integration of the SENTRON PAC3200 multifunctional measuring instrument in WinCC. • Sm@rtlib function library provides function blocks for S7-300/400 as well as faceplates and icons for WinCC and WinCC flexible from the areas of process industry, HVAC, pharmaceuticals and energy. • ACRON for WinCC/PCS 7 is used for long-term archiving and logging of process data for small to medium-sized plants, specifically in the water supply and treatment industry. Premium Add-on for configuration tools: • DCC TranslationEditor for translating multilingual projects with in-built security, convenience and globalization features. Premium Add-on for diagnostics and maintenance: • Management System Alarm Control Center for transmitting fault messages via various communication paths, such as GSM, LAN, e-mail. • PM MAINT system software is a tool for the maintenance of production plants. • PM ANALYZE system software for analysis of fault and operating messages, as well as process values. © Siemens AG 2013 HMI Software WinCC add-ons und partner management WinCC add-ons and partner management ■ Overview (continued) ■ More information Competent partners WinCC Competence Center With SIMATIC WinCC, you not only get excellent products to suit your requirements, but we will also support you with selecting a partner for your automation solution. In our global network of Siemens Automation Solution Providers you will always find competent partners in your neighborhood. In addition, we implement and support the Siemens-internal WinCC Competence Centers and the WinCC Professionals external system integrators on the basis of WinCC customer- and industryspecific and economic solutions. http://www.siemens.com/winCC/competencecenter Siemens Solution Partner Automation http://www.siemens.com/automation/solutionpartner WinCC Premium Add-on http://www.siemens.com/winCC/addons WinCC Competence Centers Mannheim Emphasis on process management • Sector-independent solutions and products in the fields: Production, environmental protection, maintenance and diagnostics • Connectivity tools, system integration, connection to SAP R/3 • Support of FDA validation and WinCC ODK • Support for advanced users with application of ODK and VBA • Customer-specific software development for panels, PCs/IPCs, and servers • Consulting on web technologies, web servers/thin clients, DataMonitor • Customer-specific workshops, e.g. VBS, VBA, and all WinCC options, e.g. Process Historian • Information Server and other WinCC topics according to customer requirements 4 Stuttgart Emphasis on production technology • Solutions for maintenance management • Web-based solutions with WinCC Nuremberg Solutions in the Oil & Gas, Metal & Mining, Pulp & Paper sectors • Network and security • Microsoft Certified • Migration from COROS to WinCC • Customized expansions also for WinCC flexible • Web solutions • Customer-specific workshops, e.g. training courses for VBS, VBA, web technologies à Web Server/Thin Client, DataMonitor à Webcenter Reports, Excell Workbook, and all WinCC topics as required by the customer (the latter with lead time) Further information can be found in the Internet at: http://www.siemens.com/wincc/competencecenter Siemens ST 80 / ST PC · 2013 4/145 © Siemens AG 2013 HMI Software SCADA System SIMATIC WinCC Open Architecture SIMATIC WinCC Open Architecture ■ Overview SIMATIC WinCC Open Architecture is a SCADA system for visualizing and operating processes, production flows, machines and plants in all industrial sectors. 4 SIMATIC WinCC OA relies throughout on object-oriented structures. Due to this consistent and well-considered use of objectoriented structures, from process pictures to the database, the engineering costs improve for SIMATIC WinCC OA customers. Distributed systems enable the connection of up to 2048 autonomous SIMATIC WinCC Open Architecture systems via one network. Each subsystem can be configured either as single-user or multi-user system, each of which may be redundant or non-redundant. • Current version: SIMATIC WinCC Open Architecture V3.11 Runs on: - Windows 8 Enterprise (64-bit) - Windows 7 Ultimate/Enterprise/Professional SP1 (32/64-bit) - Windows XP SP2/SP3 (32-bit) - Windows Server 2008 R2 (64-bit) - Red Hat Linux 5 (32/64-bit) - OpenSuse 12.1 (32/64-bit) - Sun Solaris 10 SPARC (32-bit) - Sun Solaris 10 x86 (64-bit) - VMWare ESXi Version 4.0.0 & 5.0.0 Note Native 64-bit support on 64-bit systems. ■ Benefits • Efficient engineering and flexible plant expansion - Object orientation - Unlimited number of data points - Mass engineering - Multilingual with UTF-8 support 4/146 Siemens ST 80 / ST PC · 2013 • Object-oriented data model - Mapping of setpoint values and measured values for a physical plant object onto a structured data point - Data point comprises a tree structure with data point elements - The individual process values are mapped onto the data point elements - Any number of data points can be instanced from one defined data point structure (data point type), e.g. 20 pumps of the same type. - Data point types can be embedded in other data point types, which enables more complex plant objects to be generated (e.g. one pump station comprises 2 pumps). - Graphical plant symbols can be linked with a data point type, in which case they only need to be drawn once, but can be used for all instances of the linked type. - Savings in engineering outlay. • Freely scalable - From a small single-user system up to a networked, redundant high-end system - Distributed systems of up to 2048 servers • Platform-independent - Available for Windows, Linux and Solaris • Native 64-bit support - More system memory is usable, due to native 64-bit support - This means that larger data quantity structures per server can be processed • Maximum fail-safety and availability - Hot standby redundancy - Disaster recovery system - SIL3 certification according to IEC 61508 • Platform for customized solutions - Quick and easy implementation of new processes - Swift adaptation of the control and visualization of the plant to current market requirements - Company-internal programming and in-house developments enable independence and protection of intellectual property - Structure of standardized solutions permits continuous use - Support of brand-labeling - Individual brand names for OEM developments • Openness thanks to comprehensive driver and interface options: - Modbus serial, Modbus Plus / RS485, RK512, TLS, Teleperm M, SSI driver, IEC 60870-5-101, -104, DNP3, SINAUT, PROFIBUS DP, PROFIBUS S7 + MPI, S7 TCP/IP, Modbus TCP/IP, Ethernet/IP, OPC DA Client & Server, OPC A&E Client & Server, OPC UA Client & Server (DA, AC), SNMP, BACnet, API, Kerberus • Seamless traceability of system states by means of highperformance archiving: - Data archiving in value archives (internal database format) - Data archiving in an Oracle database • Expandable by means of add-ons and solution frameworks: - Add-on for quick and easy engineering (Etool, AdvS7, etc.) - Add-on for increasing the availability (DRS, etc.) - Add-on for clarity in distributed systems (GIS Viewer, etc.) - Add-on for efficient maintenance management (AMS, Scheduler, etc.) - Add-on for mobile operability (Web Client, Ultralight Client, etc.) - Add-on for efficient building automation technology (BacNet, etc.) - Add-on for the integration of video management © Siemens AG 2013 HMI Software SCADA System SIMATIC WinCC Open Architecture SIMATIC WinCC Open Architecture ■ Application The SCADA system SIMATIC WinCC Open Architecture addresses applications with high demand for customer-specific adaptations, large and/or complex applications, as well as projects that demand special system requirements and functions. SIMATIC WinCC Open Architecture demonstrates its high performance in networked and redundant high-end control systems in particular. Integrated, high-performance communication is guaranteed from the field level to the control station, from the machine to the company headquarters. In every situation, high availability, reliable information, fast interaction, and user friendliness are guaranteed. Applications can also be changed without interrupting the process. Profitability, efficiency and safety are therefore always in equilibrium. SIMATIC WinCC Open Architecture displays its reliability in a wide range of business-critical applications. ■ Function SIMATIC WinCC Open Architecture is a very modular SCADA system. The required functionalities are realized by specific, functional entities created for various tasks. In SIMATIC WinCC Open Architecture these units are called "Managers" – they are also independent processes in software terms. WinCC OA Manager Task Event Manager (EV) The Event Manager (EV) is the processing center in WinCC OA. This unit provides a constantly updated image of all PowerTags in the memory. Each other functional unit (Manager) that wants to access the data receives it from the process image of the Event Manager and does not have to communicate directly with a controller. Conversely, a command from an operator station is initially set only as a value change in the process image of the Event Manager. The associated driver then forwards it to the corresponding target device (e.g. PLC) automatically. The Event Manager is a kind of central data distributor, in effect the communication center for WinCC OA. Furthermore, this Manager also carries out the alarm handling and can execute various arithmetic functions autonomously. Driver Manager (D) The lowest level in a WinCC OA System is represented by the process connections, referred to in WinCC OA as drivers (D). These are special programs that handle the communication with the control and field level. Since numerous different forms of communication are possible with the PLCs or telecontrol nodes, there are different drivers that can be selected. In very simple terms, the driver is a unit for converting a particular protocol into the internal communication form of WinCC OA. The driver reads the current states, measurement or counter values from the field and in the opposite direction it forwards commands and setpoints to the lower-level controllers (= the term "control" should be used here and below to represent all possible devices of the basic automation (PLC, DDC, telecontrol system, etc.)). With SIMATIC WinCC Open Architecture, ideas can be quickly and easily converted into new applications. SIMATIC WinCC Open Architecture is open for independent in-house developments and also enables own product branding. Thanks to its special system properties, SIMATIC WinCC Open Architecture meets the highest demands especially in the case of traffic solutions, building management systems and supply systems (power, water, oil and gas, etc.). ■ Design SIMATIC WinCC Open Architecture is available as a single-user runtime license, multi-user runtime license, Web Client license, and parameterization and development license. With SIMATIC WinCC Open Architecture the required license is determined, among other things, according to the number of inputs and outputs (I/O). An "I/O" refers to a data point element (DPE) whose content is exchanged either by means of drivers (e.g. S7 driver communicates with a PLC), with other software systems. Internal data point elements, i.e. DPEs without communication to the outside, are not counted for licensing. The licenses are available either with an unlimited number of I/Os or with limitations of 500 to 250 000 I/Os. The multi-user runtime license allows working simultaneously from different PCs, with the licensing taking place via the server. The active clients are then counted. The web client and the ultralight client enable the visualization and operation of process pictures over an exclusively HTTP connection between the server and the respective web client. The parameterization and development licenses extend a runtime license with the option of configuration and parameterization. They each require a server license. Data Manager (DB) The Data Manager (DB) represents the link to database. On one hand, it involves the parameterization data of an application that is to be stored in such a database. On the other hand, it involves the historical recording of changes in values or alarms. If a user wishes to query historical data at a later date, then the Data Manager completes this request and not the database itself. Siemens ST 80 / ST PC · 2013 4/147 4 © Siemens AG 2013 HMI Software SCADA System SIMATIC WinCC Open Architecture SIMATIC WinCC Open Architecture ■ Function (continued) WinCC OA Manager Task Control Manager (CTRL) WinCC OA has numerous options for implementing your own algorithms and processing. The two most important are the internal language control (CTRL) and the general application programming interface (API). Control is an extremely powerful scripting language. The processing is interpretative, so that no compilation is required. The syntax is almost identical with ANSI-C, with some modifications for simplification. This is a fully developed, procedural high-level language with multi-threading (= quasiparallel processing of individual programs; the system itself carries out the processing check). The language offers a comprehensive function library for tasks of the control and visualization technology. Control can be used as a stand-alone process (Control Manager), for animation and user interface design or for standardized, data objectoriented processing functions. The API (WinCC OA API) represents the most powerful form of functional expansion. It is configured as a C++ class library and allows the software developer to implement individual functions as an independent, additional manager (forecast system, simulation, tools, proprietary databases, etc. ). The interface to the user is created by the User Interface Manager (UI). This comprises a graphics editor (GEDI), a database editor (PARA) or the general user interface of the application (Vision module). The User Interface serves to display values, issue commands or track alarms in the alarm list. Trends and reports are also usually part of the UI. From a programming viewpoint, the user interaction in WinCC OA is completely isolated from the background processing – this is merely a view of the data of the current process image or the history. 4 UI UI UI Userinterface Editorr Userinterface Runtimee Userinterface Runtimee CTRL API Control manager API manager DB EV CON Database manager Event manager Connection to other systems D D D Driver Driver Driver Visualization, Operation UI GEDI PARA = Runtime = Graphical Editor = Database Editor Processing, Control Control = Script language Manager = Application API Programming Interface Process Image, History Event manager = Communication and Alarming Data manager, = History RDB Process Interface Driver: PLC, Field busses, DDC, Telemetry/RTU, Special drivers G_ST80_XX_00463 User Interface Manager (UI) A WinCC OA System consists of function-specific units, the managers 4/148 Siemens ST 80 / ST PC · 2013 For special tasks such as redundancy, management for distributed systems, web server, reporting, simulation, COM etc., further managers are available. The powerful configuration functions contribute to a reduction of engineering and training overheads and lead to increased flexibility and operational reliability. Special functions Task Access to external databases The database interfaces offer the possibility of access to external databases. Under Windows, the link is established via the ADO Standard. ADO (ActiveX Data Objects) is an interface developed by Microsoft for vendor-independent access to data sources of all types, primarily databases. The data source for ADO is an OLE DB Provider, although ODBC-compatible databases can also be addressed via an internal wrapper. In Linux, the Qt library is used as an interface to relational databases. Access in this case is either direct via the native DB-API or via ODBC. Application Programming Interface (API) The API offers a series of functions that enable WinCC OA to be extended with special managers. A manager means a program that communicates with the system by via a protocol defined by WinCC OA. COM (Component Object Model) This is a specification for the development of modular software components that can be used by each COM-compatible application. COM components can easily be integrated into such applications and can even be removed from an application during runtime. COM components can be programmed in a host of different languages, even though C++ is usually used for this purpose. The specifications OLE, ActiveX and DirectX are based on the COM technology. Control expansion Expansion that allows C++ functions to be added to the programming language. Panel topology/ summation signal Generation of panel hierarchies/topologies in existing or new projects and automatic creation of summation signals of the alarm data points that are located in the panels of the topology. Redundancy (see figure below) The failure safety in a redundant system is implemented by means of hot standby. Hot standby is a hardware-independent solution for high availability. This is a safety concept that consists of two interconnected server systems. Both servers are constantly in operation and are subject to the same functional loading (but only one server is ever active; the second compares the data with the primary unit at runtime). On the failure of one unit, an "on-the-fly changeover" takes place and the previously passive server assumes the leading role. This guarantees access to data or functions at all times. © Siemens AG 2013 HMI Software SCADA System SIMATIC WinCC Open Architecture SIMATIC WinCC Open Architecture ■ Function (continued) Special functions Task Special functions Task SMS Allows the sending and receiving of text messages with WinCC OA. Drag and Draw Encryption of panels and CTRL scripts/ libraries Allows your panels or scripts to be encrypted, thereby protecting your knowledge and work. Several representative graphical objects can be defined and configured for each plant object in the data model (data point type). These are pre-configured and need only be moved to the panel via drag-and-drop when the plant pictures are drawn. This saves valuable time during engineering. Script Wizard Easy-to-use tool that simplifies the creation of animated, graphical plant symbols, which saves time during engineering. Distributed systems (see the diagram below) Simple Symbols Basic package of plant symbols that have been created using the script wizard. These can be adapted quickly and easily to the specific requirements of the customer. Easy Faceplates Simple parameter assignment of predefined popup windows that display details of the associated plant symbol. Without any additional drawing outlay, several standard functions per object can be activated for the detail view (alarm display, trend display, measured value table, setpoint value table, address table, notes). Permits the coupling of two or more autonomous WinCC OA systems via a network. Each subsystem of a distributed system can be configured either as a single-user or multi-user system, each of which may be redundant or non-redundant. A sub-system in this context means a server on which an Event Manager is running, whereby in case of redundancy both redundantly operating servers are considered as one system. Operational station 1 UI UI Userinterface Runtime Userinterface Runtime Server 2 CTRL CTRL Control manager Control manager EV DB Event manager Database manager REDU REDU Redundancy manager Redundancy manager Event manager D D Driver Driver Process connection The diagram shows a detailed representation of the two computers Server 1 and Server 2. Server 1 is in the management mode (active) and Server 2 is in hot standby mode (passive). In the case of redundant operation, the UIs of both operator stations are connected to both Event Managers, however only the data of the active system is displayed on both UIs. Process connection DB Database manager G_ST80_XX_00479 Message direction Server 1 ACTIVE 4 Operational station 2 HOT-STANDBY The Event Manager of the passive system is restricted exclusively to communication with the Event Manager of the active system for comparison of the process data (it sends no data to the connected UIs or it discards messages from the drivers – this can be seen in the figure with the switches on the UIs or on the passive Event Manager). Siemens ST 80 / ST PC · 2013 4/149 © Siemens AG 2013 HMI Software SCADA System SIMATIC WinCC Open Architecture SIMATIC WinCC Open Architecture ■ Integration Integration in automation solutions SIMATIC WinCC Open Architecture is an open SCADA system with comprehensive drivers and flexible options for connection to other external systems. Depending on the communications protocol and the bus physics used, specific drivers are used in each case: • Serial protocols: RK512, 3964R, etc. • Ethernet: Industrial Ethernet (S7), Modbus TCP (OpenModbus), Ethernet IP (AB), etc. • Telecontrol systems: SINAUT, SSI (Ethernet), IEC 60870-5-101, IEC 60870-5-104, etc. • Vendor-independent interfaces: OPC UA, etc. In SIMATIC WinCC Open Architecture, several drivers can be operated in parallel. These can be of the same type or also of different types. It is possible in a SIMATIC WinCC Open Architecture system, for example, to establish connections via the S7 protocol to a SIMATIC controller, via IEC 60870-5-104 to a telecontrol system, and via OPC DA to any OPC server at the same time. Coupling overview 4 Protocol Description Protocol Description SIMATIC S7 via TCP/IP and MPI SSI OPC Client (Data Access) • Compatibility with the specifications DA 1.0 and 2.05a • Connection to inproc, local or remote server • Connection with up to 20 servers at the same time • Monitoring of the connection to the server and automatic reconnection if the connection is interrupted. • Address browsing if supported by the server. • Benefits of the CALL-R functionality for CALL-R servers (simplified parameter assignment) Is used for the interfacing of SAT remote control systems. The data is exchanged via the LAN (Ethernet, IEEE 802.3); the frame formats used are the SSI formats defined by SAT. The SK 1703 telecontrol components with a suitable communication card (KE/ET) are supported. IEC 60870-5-101, -104 IEC drivers are standardized telecontrol drivers that can process proprietary frames. IEC stands for International Electrotechnical Commission, the international standardization committee for electrical engineering. • IEC 60870-5-104 for data exchange via TCP/IP • IEC 60870-5-101 for serial connection DNP3 The DNP3 (Distributed Network Protocol 3) driver is an open, rugged and modern protocol which exhibits characteristics and strengths similar to the IEC driver. The transfer of any number of frames with different data types takes place between the WinCC OA System (Master) and the remote stations (Slave). SINAUT SINAUT (SIemens Network AUTomation) is a communication protocol for automated monitoring and control of remote process stations on the basis of SIMATIC S7. Communication takes place via TCP/IP. SNMP Manager & Agent SNMP (Simple Network Management Protocol) is a protocol for monitoring network elements (servers, workstations, routers, switches, hubs, etc.) and their functions. • SNMP Manager supports SNMP V1, V2, and V3 • SNMP Agent supports SNMP V1 and V2 BACnet over IP – driver BACnet (Building Automation and Control Networks) is a standardized protocol for building automation and has been set by the ASHRAE (American Society of Heating, Refrigerating and Air-conditioning Engineers) as a guideline to provide a uniform and cross-company standard for data communication within and between building automation systems. OPC Server (Data Access) OPC Alarms & Events • Corresponds to Data Access 2.05a specification (reading/writing of online values). • Is to be started as a manager just like other drivers. • The provided DPEs (server -> client) can be easily and quickly defined via data point groups. • DPEs can be declared as readable (read-only access is permitted; Group OPCRead) or as writable items (Group OPCWrite). • Clients can browse the WinCC OA OPC Server hierarchically. OPC Alarms & Events (abbreviated to OPC A&E) is, in addition to Data Access, a further standard for performing central alarm management on a cross-vendor basis. OPC A&E is used to ensure the link to other control systems and the display of alarms/events in a hierarchical system. OPC UA (Unified Architecture) • The OPC UA client supports the OPC UA standards Data Access and Alarms & Conditions. • The OPC UA Server supports the OPC UA standards Data Access and Alarms & Conditions. Modbus TCP Modbus/TCP is based on the serial Modbus protocol, which was adapted for TCP/IP. The Modbus/TCP driver can be used simultaneously for Modbus/TCP or UNICOS. Serial: RK512/3964R Is used for interfacing a PLC via the 3964R/ RK512 protocol Cerberus Cerberus is a fire, intrusion and gas alarm system. The Cerberus driver guarantees communication to and from the central fire alarm systems and building security facilities in the event a fire, gas or intruder alarm. The BACnet Standard 2004 is supported in accordance with the PIC list (see product documentation) Dynamic Logic – driver The Dynamic Logic driver communicates with different Dynamic Logic devices via the "FSK outstation protocol". Applicom General Interface Applicom is, among other things, a manufacturer of I/O cards and software tools, with a wide range of applications in automation engineering. The Applicom products are compatible with many common fieldbus systems and communications components. Further drivers on request or via C++ API 4/150 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 HMI Software SCADA System SIMATIC WinCC Open Architecture SIMATIC WinCC Open Architecture ■ Technical specifications Type SIMATIC WinCC Open Architecture V3.11 Type Operating system • Windows 8 Enterprise (64-bit) Functionality/quantity structure • Windows 7 Ultimate/Enterprise/Professional SP1 (32/64-bit) SIMATIC WinCC Open Architecture Number of messages 150,000 2) Message text (number of characters) System-limited 1) • Windows Server 2008 R2 (64-bit) • Red Hat Linux 5 (32/64-bit) Message archive System-limited 1) Process values per message 1 process value + up to 32 alarm associated values per message Constant load of messages, max. 500/s 2) Message burst, max. 15,000/10 s every 5 min 2) • Windows XP SP2/SP3 (32-bit) • OpenSuse 12.1 (32/64-bit) • Sun Solaris 10 SPARC (32-bit) • Sun Solaris 10 x86 (64-bit) • VMWare ESXi Version 4.0.0 & 5.0.0 Note: Native 64-bit support on 64-bit systems PC hardware requirements 1) Archives Archive data points Max. 250,000 per server 2) Archive types < 20 parallel logs, different retention period for each log Processor type Intel Pentium or equivalent Minimum Intel Pentium IV 1.6 GHz (or better)2)3) Recommended • Client: Intel Pentium IV/Core2/i3, 2 GHz2)3) • Server: Intel Core i3 CPU Dual, 3 GHz2) • Server large system4): Intel(R) Core(TM) i5/i7 CPU Dual / Quad, 3 GHz2)3) Data storage format Oracle or file system Measured values per second, max. Server/single-user station: 7,000/s 2) 3) Minimum 2 GB 2) Archives System-limited 1) Recommended • Client: 2 GB 2)3) • Server: 8 GB 2)3) • Server large system: 16 GB 2) Type SIMATIC WinCC Open Architecture Table size System-limited by ORACLE database User archive RAM Hard disk (available memory for installation) Minimum HD with 800 MB available 2) Recommended Server large system with local logging: SCSI LVD Controller, WIDE SCSI / LVD HDD or comparable storage system with at least 500 MB of available space 2) Number of screens System-limited 1) Number of objects per screen System-limited 1) Number of controllable fields per screen System-limited 1) PowerTags < 750,000 per server 2) User administration Screen and graphics card (TrueColor) User accounts < 4096 Minimum 1024 x 768 2) Configuration languages 2 (De, En) Recommended 1280 x 1024 2) Runtime languages 40 (of which 8 Asian) Mouse and keyboard Mouse, keyboard Multi-user system DVD drive for software installation Server < 2048 2) 4) Local power user rights • for installation • for operation Number of clients < 244 per server 2) 5) 1) 4 Graphics system For actual use in plants, the hardware requirements are largely dependent on the project size and the dynamic response of the process variables. Whenever possible, use rugged, high-quality hardware with corresponding functionalities such as redundant power supply units or RAID hard disks. WinCC OA supports dual and multi-processor mode and benefits significantly from the fact that each WinCC OA Manager can be assigned to one processor core as a system process. At the same time, however, it is important that the individual cores offer the highest possible performance (high clocking), since load-critical core processes such as the event manager run on exactly one core (for this reason, multi-core machines with low-clocked cores are unsuitable for WinCC OA). As for RAM, CPU and HDD, the usual rule applies: more is better 2) System requirements generally only refer to WinCC OA Version 3.11 under the supported versions of the Windows and Linux operating systems 3) A precondition for the minimum requirement is that the operating system used does not have any greater requirements itself 4) With a large system it is essential that the system permits not only the highest data point numbers but also a high dynamic response 1) Dependent on the available storage space 2) Dependent on the system configuration and the system load (due to the event-oriented architecture, the system load is essentially determined by the change rates of the values to be processed) 3) By means of high-performance hardware configuration (one archiving cluster and approx. 120 distributed systems that archive parallel values in the cluster): 200,000 archived value changes per second 4) Physical limit: <2048, in practice systems have already been implemented with up to 550 distributed systems 5) Physical limit: < 244 clients per server, recommended: max. 100 clients per server WinCC OA is ideally suited for use in very large distributed systems. The optimum design of such systems demands corresponding system knowledge of WinCC OA. Due to the eventoriented processing, individual design parameters can be increased or reduced as necessary in actual applications. Siemens ST 80 / ST PC · 2013 4/151 © Siemens AG 2013 HMI Software SCADA System SIMATIC WinCC Open Architecture SIMATIC WinCC Open Architecture ■ Ordering data Order No. SIMATIC WinCC Open Architecture system software V3.11 WinCC OA core components WinCC OA Server Language/script versions: De, En; with license for: WinCC OA single-user station 500 I/O V3.11 License for single-user station with up to 500 I/Os of any type (bit, integer), alerting, extended trend, historical recording, not expandable to more than one operator station, not expandable by means of add-ons, including S7 driver, OPC client, OPC server, and OPC UA client. 4 WinCC OA Server I/O V3.11 License for server (without operator station licenses), alerting, extended trend, historical recording, including S7 driver, OPC client, OPC server, and OPC UA client. • WinCC OA Server 1,000 I/O V3.11 with a max. of 1,000 I/Os of any type • WinCC OA Server 3,000 I/O V3.11 with a maximum of 3,000 I/Os of any type • WinCC OA Server 5,000 I/O V3.11 with a max. of 5,000 I/Os of any type • WinCC OA Server 10,000 I/O V3.11 with a max. of 10,000 I/Os of any type • WinCC OA Server 15,000 I/O V3.11 with a max. of 15,000 I/Os of any type • WinCC OA Server 25,000 I/O V3.11 with a max. of 25,000 I/Os of any type • WinCC OA Server 50,000 I/O V3.11 with a max. of 50,000 I/Os of any type • WinCC OA Server 75,000 I/O V3.11 with a max. of 75,000 I/Os of any type • WinCC OA Server 100,000 I/O V3.11 with a max. of 100,000 I/Os of any type • WinCC OA Server 150,000 I/O V3.11 with a max. of 150,000 I/Os of any type • WinCC OA Server 200,000 I/O V3.11 with a maximum of 200,000 I/Os of any type • WinCC OA Server 250,000 I/O V3.11 with a maximum of 250,000 I/Os of any type 4/152 Order No. WinCC OA Server unlimited V3.11 6AV6351-1HA31-1AA0 6AV6351-1HB31-1AA0 6AV6351-1HC31-1AA0 6AV6351-1HD31-1AA0 License for server and one singleuser station (expandable to several operator stations by means of clients) with unlimited number of I/O, alerting, extended trend, historical recording, including S7 driver, OPC client, OPC server, and OPC UA client. WinCC OA Dongle V3.11 Hardware dongle on the USB port for operation with a hardware-independent license attached to the dongle, which can also extend the hardware-linked license of the operator station or server on a temporary basis. 6AV6351-1AH31-1AA0 WinCC OA on data medium WinCC OA Software DVD – current version on disk 6AV6351-1AX31-1AA0 WinCC OA Client floating Language/script versions: De, En; with license for: WinCC OA Client V3.11 Additional operator station license with all server operator station functionalities. The client license can be installed on more than one PC – only the number of simultaneously active clients is counted. 6AV6351-1HE31-1AA0 WinCC OA Web User Interface Language versions: De, En; with license for: 6AV6351-1HF31-1AA0 WinCC OA Web Client V3.11 Web client license for WinCC OA Server. Only the number of simultaneously active web clients is counted. 6AV6351-1HG31-1AA0 6AV6351-1HH31-1AA0 6AV6351-1HJ31-1AA0 6AV6351-1HK31-1AA0 6AV6351-1HL31-1AA0 6AV6351-1HM31-1AA0 6AV6351-1HN31-1AA0 Siemens ST 80 / ST PC · 2013 6AV6351-1HP31-1AA0 6AV6351-1CP31-1AA0 6AV6351-1DP31-1AA0 © Siemens AG 2013 HMI Software SCADA System SIMATIC WinCC Open Architecture SIMATIC WinCC Open Architecture ■ Ordering data Order No. WinCC OA Ultralight Client WinCC OA Ultralight PC Client Licenses for one or several ultralight clients running on a laptop or PC. Only the number of simultaneously active ultralight clients is counted. Please note restrictions of the ultralight client according to the online help. • WinCC OA 1 Ultralight PC Client License for one ultralight client • WinCC OA 3 Ultralight PC Clients License for 3 ultralight clients • WinCC OA 10 Ultralight PC Clients License for 10 ultralight clients WinCC OA Ultralight Mobile Client Licenses for one or several ultralight clients running on a smartphone or tablet PC. Only the number of simultaneously active ultralight clients is counted. Please note restrictions of the ultralight client according to the online help. • WinCC OA 1 Ultralight Mobile Client License for one ultralight client • WinCC OA 3 Ultralight Mobile Clients License for 3 ultralight clients • WinCC OA 10 Ultralight Mobile Clients License for 10 ultralight clients 6AV6351-1JA31-1AA0 6AV6351-1JB31-1AA0 6AV6351-1JC31-1AA0 6AV6351-1JG31-1AA0 Order No. WinCC OA API interface gen. V3.11 Application programming interface for the integration of customer-specific managers or drivers. One license is required for each development workstation. We strongly recommend the participation in a Certified WinCC OA Developer Workshop when ordering this product for the first time. 6AV6351-1EK31-1AA0 WinCC OA Custom Driver V3.11 Extends a WinCC OA server license with the option of communication with a customer-specific driver. One license is required for each customer-specific driver. 6AV6351-1EL31-1AA0 WinCC OA Custom Manager V3.11 Extends a WinCC OA server license with the option of communicating with a customer-specific manager. One license is required for each customer-specific manager 6AV6351-1EM31-1AA0 WinCC OA redundancy 6AV6351-1JG31-1AA0 6AV6351-1JH31-1AA0 WinCC OA Redundancy V3.11 Extends a WinCC OA Server with the option of bumpless switchover to a hot standby partner. 6AV6351-1FP31-1AA0 4 WinCC OA distributed systems 6AV6351-1JJ31-1AA0 WinCC OA parameter assignment and development license WinCC OA Para for single-user station V3.11 Parameterization and development license for single-user station, graphic editor with symbol catalog and ActiveX Controls, user-friendly script development language, alerting, extended trend, historical recording. Requires a corresponding single-user station license. 6AV6351-1EA31-1AA0 WinCC OA Para V3.11 Parameterization and development license for server, graphic editor with symbol catalog and ActiveX Controls, user-friendly script development language, alerting, extended trend, historical recording. Requires corresponding server license. 6AV6351-1EP31-1AA0 WinCC OA ETool V3.11 License for the use of the integrated WinCC OA ETool engineering environment, including the object library S7-BaseLib. Intellectual property right owner: Siemens AG. 6AV6351-1EJ31-1AA0 WinCC OA distributed systems V3.11 Extends a WinCC OA Server to include the Multiserver option. 6AV6351-1GP31-1AA0 WinCC OA Disaster Recovery System WinCC OA Disaster Recovery Center V3.11 Allows the configuration of a remote backup control center. A disaster recovery center comprises two distributed systems. Each system can be redundant or non-redundant. Requires Oracle databases and RDB. Refer to the online help for example configurations. Each server in the Disaster Recovery System requires one WinCC OA Disaster Recovery Center option. 6AV6352-1AA31-1AA0 Siemens ST 80 / ST PC · 2013 4/153 © Siemens AG 2013 HMI Software SCADA System SIMATIC WinCC Open Architecture SIMATIC WinCC Open Architecture ■ Ordering data Order No. SIMATIC WinCC Open Architecture V3.11 communication 4 Order No. WinCC OA SINAUT 25 devices SINAUT driver for connecting up to 25 controllers 6AV6352-1BR31-1AA0 WinCC OA SINAUT 50 devices SINAUT driver for connecting up to 50 controllers 6AV6352-1BS31-1AA0 WinCC OA TLS driver Driver in accordance with TLS regulations in connection with Siemens Commbox (see separate data sheet). 6AV6352-1BA31-1AA0 WinCC OA Teleperm M Driver for Teleperm M Bus C275 (requires an Acotex Comm Box) 6AV6352-1BB31-1AA0 WinCC OA SINAUT 250 devices SINAUT driver for connecting up to 250 controllers 6AV6352-1BT31-1AA0 WinCC OA S7 TCP/IP driver TCP/IP for Siemens Industrial Ethernet 6AV6352-1BC31-1AA0 WinCC OA SINAUT unlimited SINAUT driver – unlimited license 6AV6352-1BU31-1AA0 WinCC OA Modbus TCP/IP driver TCP/IP for Schneider Modbus 6AV6352-1BD31-1AA0 6AV6352-1CA31-1AA0 WinCC OA Modbus serial Serial driver for Schneider Modbus 6AV6352-1BE31-1AA0 WinCC OA RK512 Driver for connection via 3964R / RK512 protocol 6AV6352-1CB31-1AA0 WinCC OA SSI driver Driver for SAT telecontrol components 6AV6352-1BF31-1AA0 WinCC OA PROFIBUS DP Driver PROFIBUS DP, an Applicom card is required 6AV6352-1CC31-1AA0 WinCC OA SNMP Driver SNMP – network monitoring (V2&V3) 6AV6352-1BG31-1AA0 WinCC OA PROFIBUS S7 Driver PROFIBUS S7 + MPI, an Applicom card is required 6AV6352-1BH31-1AA0 WinCC OA Omron FINS TCP-IP Driver Omron FINSTCP-IP, an Applicom card is required 6AV6352-1CE31-1AA0 WinCC OA IEC 104 Driver IEC 60870-5-104 6AV6352-1BJ31-1AA0 WinCC OA GE Fanuc SRTP Driver GE Fanuc SRTP, an Applicom card is required 6AV6352-1CF31-1AA0 WinCC OA IEC 101 Driver IEC 60870-5-101 WinCC OA DNP3 10 devices Driver DNP3 for connecting up to 10 DNP3 devices 6AV6352-1BK31-1AA0 WinCC OA Allen Bradley Ethernet/IP Driver Allen Bradley Ethernet/IP, an Applicom card is required. 6AV6352-1CG31-1AA0 WinCC OA DNP3 25 devices Driver DNP3 for connecting up to 25 DNP3 devices 6AV6352-1BL31-1AA0 6AV6352-1CH31-1AA0 WinCC OA DNP3 50 devices Driver DNP3 for connecting up to 50 DNP3 devices 6AV6352-1BM31-1AA0 WinCC OA Cerberus Driver for connection with the Siemens DMS7000 / Cerberus fire alarm system. Communication is implemented via the C-Bus (Cer-Ban) using the serial interface RS 232 (MK 7022). 6AV6352-1BN31-1AA0 WinCC OA OPC UA Server Driver for OPC UA DA and OPC UA AC Server 6AV6352-1CJ31-1AA0 WinCC OA DNP3 250 devices Driver DNP3 for connecting up to 250 DNP3 devices WinCC OA DNP3 unlimited Driver DNP3 – unlimited license 6AV6352-1BP31-1AA0 WinCC OA SINAUT 10 devices SINAUT driver for connecting up to 10 controllers 6AV6352-1BQ31-1AA0 ■ More information Further information can be found in the Internet at: http://www.siemens.com/wincc-open-architecture 4/154 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 HMI Software SCADA System SIMATIC WinCC Open Architecture SIMATIC WinCC Open Architecture Add-ons ■ Overview SIMATIC WinCC Open Architecture is a SCADA system for visualizing and operating processes, production flows, machines and plants in all industrial sectors. SIMATIC WinCC OA is built consistently on object-oriented structures. The rigorous and well-considered use of objectoriented structures, from process images to the database, help to improve engineering costs for SIMATIC WinCC OA customers. Distributed systems enable the connection of up to 2048 autonomous SIMATIC WinCC Open Architecture systems via one network. Each subsystem can be configured either as singleuser or multi-user system, each of which may be redundant or non-redundant. • Current version: SIMATIC WinCC Open Architecture V3.11 Runs on: - Windows 8 Enterprise (64-bit) - Windows 7 Ultimate/Enterprise/Professional SP1 (32/64-bit) - Windows XP SP2/SP3 (32-bit) - Windows Server 2008 R2 (64-bit) - Red Hat Linux 5 (32/64-bit) - OpenSuse 12.1 (32/64-bit) - Sun Solaris 10 SPARC (32-bit) - Sun Solaris 10 x86 (64-bit) - VMWare ESXi Version 4.0.0 & 5.0.0 Note: Native 64-bit support on 64-bit systems. ■ Function SIMATIC WinCC Open Architecture add-ons The universal WinCC Open Architecture basic software is the basis for modular expansions. These functional expansions are available in the form of WinCC Open Architecture add-ons. Field devices or other connected systems 4 MODBUS (TCP) WinCC OA Server (multi-user system) OPC UA (TCP) WinCC OA Server (stand alone system) Operational station System 3 Operational station System 2 WinCC OA System communication TCP System 1 WinCC OA Server (redundant) Operational station Operational station Operational station G_ST80_XX_00480 S7 Industrial Ethernet (TCP) Distributed systems with WinCC OA Siemens ST 80 / ST PC · 2013 4/155 © Siemens AG 2013 HMI Software SCADA System SIMATIC WinCC Open Architecture SIMATIC WinCC Open Architecture Add-ons ■ Function (continued) 4 Add-ons Task Add-ons Task ETool The engineering tool ETool offers significant benefits in engineering in the case of combined WinCC OA and SIMATIC STEP7/PCS7 projects. It provides a user-friendly engineering environment that permits easy, integrated and fast configuration on the basis of the WinCC OA mass parameterization. Video (see figure below) Enables the integration of a video management system in WinCC OA. Through the combination of SCADA and video monitoring in one system, the costs for separate video interfaces and the additional expense of maintenance and operation can be saved, and the period of training for operating personnel can also be reduced. BACnet BACnet provides an integrated BACnet-compliant online/offline engineering solution for building automation technology, including object library. Designed for heating, ventilation and air-conditioning, lighting control and safety systems. HTTP server For displaying WinCC OA data via Intranet and Web. Authentication via Kerberos A WinCC OA system can be exposed to a variety of attacks. An unauthorized WinCC OA System could set up a connection to the distribution manager or hackers could try to manipulate WinCC OA messages. Secure authentication has been developed to prevent such attacks. The authentication based on Kerberos enables each WinCC OA component to verify the identity of another component. WinCC OA servers can verify the identity of the clients and clients can verify the identity of the servers. In addition, Kerberos ensures that messages are not modified during their transmission (capture-replay attacks are prevented). Furthermore, it is also possible to send messages in encrypted form. AMS (Advanced Maintenance Suite) For the effective planning, administration, implementation and monitoring of maintenance work and faults. The processes are evaluated by means of statistics and reports are communicated. Web client From a technical standpoint, the WinCC OA Web Client is a plug-in that is downloaded via the web browser (which is used on the client computer) and a WinCC OA UI Manager is then displayed embedded in the HTML page. No WinCC OA installation on the client computer is required, except for the required web client plug-ins. Ultralight client A "thin client" that supports access to the plant via a mobile device (such as a cell phone or tablet) in addition to a PC workstation. Access is possible via a standard Web browser using native Web technologies (Javascript, SVG) without the need for any additional installations. It provides a user interface even at those locations with Internet connections offering very low bandwidth, as only the most essential data is transferred. Disaster Recovery System (see figure below) This system expands the simple redundancy to include a second redundant system, to which the system can switch over in the event of a fault (e.g. fire or explosion in the building of the primary system). By means of this additional local redundancy, the highest level of system stability is obtained. S7 AdvancedLib object library The S7 AdvancedLib (AdvS7) is an industry-independent object library that permits the use and visualization of objects from the process control system (e.g.: drives, valves, regulators, motors, etc.) in a project with WinCC OA and S7. In addition to the WinCC OA and AdvS7 license, the use of S7 AdvancedLib requires the use of the relevant library on the SIMATIC side. Maintenance package Includes the following functions: Operating hours counter, operating cycle counter and maintenance log. Scheduler Permits the creation, parameterization and management of time programs that allow the time and event-driven triggering of specific actions. Recipes WinCC OA recipes allow setpoints or commands for certain data point elements to be sent simultaneously. Based on "recipe types", which define the quantity of the assigned data point elements, recipes are created that send their values to the data point elements upon activation. With the help of this viewer, standardized cards of a geo-information system (GIS) can be fully integrated in WinCC OA. Furthermore, it is possible to display all WinCC OA objects in the cards. GIS Viewer Powerful report generator directly in Microsoft Excel. Templates can be created easily and directly in Excel. If a report has to be created over a defined period of time, the system accesses the template and automatically completes it with data from the WinCC OA process database. Reports can also be created, printed and saved on a timecontrolled basis, without any need for user access. The Excel Report fully supports compression structures (AC - archive compression) of WinCC OA. Excel report Communication Center 4/156 Stands for modern alarm management/remote alerting and communication using the latest standards and various media. The Communication Center creates synergies by using the various interfaces for remote alerting via the control system. Text message and email media are covered with the Communication Center. Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 HMI Software SCADA System SIMATIC WinCC Open Architecture SIMATIC WinCC Open Architecture Add-ons ■ Function (continued) Video workstation Monitor 1 Operator keyboard mouse joystick Video monitor 1 Video monitor 2 (optional) Control monitor (optional) Encoder Control commands TCP/IP connection Decoder Cameras or crossbars Network video recorder WinCC OA Server Control of monitor wall via POSA protocol Monitor wall (monitors 2 ... n) G_ST80_XX_00481 4 Network topology Video Primary Server System (PSS) Secondary Server System (SSS) Database in Oracle Cluster WinCC OA active Server (A) WinCC OA Hot-Standby System WinCC OA passive Server (B) Operating Interface with one or two interfaces WinCC OA active Server (C) WinCC OA Hot-Standby System WinCC OA passive Server (D) Field device or other connected systems like for example OPC UA G_ST80_XX_00482 Database in Oracle Cluster Disaster Recovery System architecture with WinCC OA Siemens ST 80 / ST PC · 2013 4/157 © Siemens AG 2013 HMI Software SCADA System SIMATIC WinCC Open Architecture SIMATIC WinCC Open Architecture Add-ons ■ Ordering data Order No. SIMATIC WinCC Open Architecture add-ons 4 Order No. Solution Frameworks WinCC OA PMS Application framework for the implementation of production management systems. The framework offers functions for recording and evaluating production and batch-related quality data. This item is not available as a product but only in combination with consulting and additional testing overhead. 6AV6352-1EA31-1AA0 WinCC OA topology package The topology package is an application framework enabling the topological coloring of network views. A qualitative statement is made regarding which parts of a network are directly connected to which infeed units in a connection established by switching elements. Only available in combination with consulting and additional testing overhead. 6AV6352-1EB31-1AA0 WinCC OA ACAS WinCC OA Advanced Command Authority Suite framework for managing and visualizing authority settings. The license includes the management panel and panel expansions for alarm, horn and acknowledgement functions. This item is not available as a product but only in combination with consulting and additional testing overhead. 6AV6352-1EC31-1AA0 WinCC OA BACnet driver + diagnostics Extends a WinCC OA Server to include a license for using the WinCC OA BACnet online engineering environment consisting of WinCC OA BACnet driver, WinCC OA BACnet object library including faceplates, and WinCC OA BACnet browser (max. 5,000 objects per server). 6AV6352-1DA31-1AA0 WinCC OA BACnet Engineering Extends a WinCC OA Server to include a license for using the WinCC OA BACnet engineering environment consisting of WinCC OA BACnet browser, WinCC OA EDE-Tool + EDE file interface (requires the WinCC OA engineering license) (max. 5,000 objects per server). 6AV6352-1DB31-1AA0 WinCC OA GIS GIS viewer for displaying ESRI Shapes Files. One license is required for each UI. Can be used in WinCC OA Client and Web Client. Maps are not included. Dynamization performed using Ctrl scripting. 6AV6352-1DC31-1AA0 WinCC OA S7 AdvancedLib Runtime license for using the object library WinCC OA S7 AdvancedLib, coordinated with the SIMATIC object library also supplied, which is free of charge until revoked. License required for each server. 6AV6352-1DD31-1AA0 6AV6352-1DE31-1AA0 WinCC OA Report 1 UI Expands a WinCC OA Server by 1 active Excel report process; Microsoft Excel is not included. 6AV6352-1FA31-1AA0 WinCC OA Maintenance Maintenance management for recording operating hours, switching cycles, alarm handling and notepad function. License required for each server. 6AV6352-1FB31-1AA0 WinCC OA Scheduler Daily, weekly and monthly program, as well as individual non-periodic events with consideration of public holidays, assignment of priority and override function. License required for each server. 6AV6352-1DF31-1AA0 WinCC OA Report 2 UI Expands a WinCC OA Server by 2 parallel active Excel report processes; Microsoft Excel is not included. 6AV6352-1FC31-1AA0 WinCC OA Recipe Creation of any recipe types and recipes, acceptance of current process values as recipe, activation/download to data points, import and export (Microsoft Excel). License required for each server. 6AV6352-1DG31-1AA0 WinCC OA Report 5 UI Expands a WinCC OA Server by 5 parallel active Excel report processes; Microsoft Excel is not included. WinCC OA Report 10 UI Expands a WinCC OA Server by 10 parallel active Excel report processes; Microsoft Excel is not included. 6AV6352-1FD31-1AA0 WinCC OA RDB RDB Oracle connection for WinCC OA Server S-UL. Oracle licenses are not included. License required for each server. 6AV6352-1DH31-1AA0 4/158 Excel report Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 HMI Software SCADA System SIMATIC WinCC Open Architecture SIMATIC WinCC Open Architecture Add-ons ■ Ordering data Order No. Communication Center WinCC OA CommCenter 1 Basic package for 25 alarms. Output as text message or e-mail is possible. Price per WinCC OA Server. 6AV6352-1GA31-1AA0 WinCC OA CommCenter 2 Basic package for 250 alarms. Output as text message or e-mail is possible. Price per WinCC OA Server. 6AV6352-1GB31-1AA0 WinCC OA CommCenter 3 Basic package for 2,500 alarms. Output as text message or e-mail is possible. Price per WinCC OA Server. 6AV6352-1GC31-1AA0 WinCC OA CommCenter 4 Basic package for unlimited alarms. Output as text message or e-mail is possible. Price per WinCC OA Server. 6AV6352-1GD31-1AA0 Video management Order No. WinCC OA video driver RS 485TVI Driver for controlling TVI pan-tilt cameras. One license is required for each WinCC OA Server. 6AV6352-1HK31-1AA0 WinCC OA video driver SNK RS485 Funkwerk Driver for controlling Funkwerk pan-tilt cameras. One license is required for each WinCC OA Server. 6AV6352-1HL31-1AA0 WinCC OA video driver SNK RS485 Globe Driver for controlling Globe pan-tilt cameras. One license is required for each WinCC OA Server. 6AV6352-1HM31-1AA0 WinCC OA video driver SNK development Driver development for controlling pan-tilt cameras 6AV6352-1HN31-1AA0 WinCC OA video driver for cameras with RCP+ and H264 Drivers for controlling cameras with RCP+ and H264. One license is required for each WinCC OA Server. 6AV6352-1HP31-1AA0 WinCC OA video driver dev. Driver development for controlling decoder/encoder/host protocols 6AV6352-1HQ31-1AA0 WinCC OA video driver Bosch IntKey Driver for controlling Bosch IntKey console controller. One license is required per server 6AV6352-1HR31-1AA0 WinCC OA Video driver development for console controllers Driver development for controlling console controllers 6AV6352-1HS31-1AA0 6AV6352-1HT31-1AA0 6AV6352-1HU31-1AA0 WinCC OA Video Light Including 4 streams. Possible video operator station configuration: 1 x quad image or 2 dual images or 4 single images. Not expandable with further streams, redundancy not possible. 6AV6352-1HA31-1AA0 WinCC OA Video Basic Including 7 streams. Possible video operator station configuration: Display in quad, dual or single images. Expandable by additional streams, redundancy is possible. One license is required for each WinCC OA Server. 6AV6352-1HB31-1AA0 WinCC OA Video Extension 5 Streams Extends WinCC OA Video Basic by 5 streams 6AV6352-1HC31-1AA0 WinCC OA Video Extension 7 Streams Extends WinCC OA Video Basic by 7 streams 6AV6352-1HD31-1AA0 WinCC OA Video Extension 32 Streams Extends WinCC OA Video Basic by 32 streams 6AV6352-1HE31-1AA0 WinCC OA video driver Bosch VRM (NVR) Drivers for controlling Bosch video recording equipment / NVR. One license is required per server WinCC OA Video Extension 128 Streams Extends WinCC OA Video Basic by 128 streams 6AV6352-1HF31-1AA0 WinCC OA video driver development for recording equipment / NVR Driver development for video recorder equipment / NVR WinCC OA Video Extension 256 Streams Extends WinCC OA Video Basic by 256 streams 6AV6352-1HG31-1AA0 WinCC OA Video Extension 512 Streams Extends WinCC OA Video Basic by 512 streams 6AV6352-1HH31-1AA0 WinCC OA video driver SNK RS485 eneo Driver for controlling eneo pan-tilt cameras. One license is required for each WinCC OA Server. 6AV6352-1HJ31-1AA0 4 HTTP server WinCC OA HTTP Server Forwarding of alarms, events and WinCC OA information to the Internet in HTML format including 1 HTTP connection. 6AV6352-1KA31-1AA0 WinCC OA HTTP Server Extension5 Extends the WinCC OA HTTP server by 5 HTTP connections. 6AV6352-1KB31-1AA0 WinCC OA HTTP Server Extension10 Extends the WinCC OA HTTP server by 10 HTTP connections. 6AV6352-1KC31-1AA0 WinCC OA HTTP Server Extension25 Extends the WinCC OA HTTP server by 25 HTTP connections. 6AV6352-1KD31-1AA0 Siemens ST 80 / ST PC · 2013 4/159 © Siemens AG 2013 HMI Software SCADA System SIMATIC WinCC Open Architecture SIMATIC WinCC Open Architecture Add-ons ■ Ordering data Order No. Kerberos WinCC OA Secure Extends a WinCC OA Server to include protection by Kerberos. Each WinCC OA Server requires a separate WinCC OA Secure license. 6AV6352-1LA31-1AA0 AMS (Advanced Maintenance Suite) 4 AMS Starter Package 20A/E This fully functional trial license valid for 90 days includes the AMS application as well as up to 20 A/E = 20 checklists assigned to alarm/event DP. 1)2)3) 6AV6352-1MA31-1AA0 AMS Entry 20 A/E The license includes the AMS application as well as up to 20 A/E = 20 checklists assigned to alarm/event DP. 1)2)3) 6AV6352-1MB31-1AA0 AMS Small 100 A/E The license includes the AMS application as well as up to 100 A/E = 100 checklists assigned to alarm/event DP. 1)2)3) 6AV6352-1MC31-1AA0 AMS Medium 1,000 A/E The license includes the AMS application as well as up to 1,000 A/E = 1,000 checklists assigned to alarm/event DP. 1)2)3) 6AV6352-1MD31-1AA0 AMS Large 5,000 A/E The license includes the AMS application as well as up to 5,000 A/E = 5,000 checklists assigned to alarm/event DP. 1)2)3) 6AV6352-1ME31-1AA0 ■ More information Additional information is available on the Internet at: http://www.siemens.com/wincc-open-architecture 4/160 Siemens ST 80 / ST PC · 2013 Order No. AMS Upgrade Large The license contains an upgrade of the AMS Large 5,000 A/E license with 1,000 A/E = 1,000 checklists assigned to alarm/event DP. 6AV6352-1MF31-1AA0 AMS UL A/E The license includes the AMS application as well as an unlimited number of alarm/event DP checklist assignments. 1)2)3) 6AV6352-1MG31-1AA0 AMS Client 2 UI Operating station license for simultaneous use of no more than 2 parallel client sessions. The client license can be installed on more than one PC – only the number of simultaneously active clients is counted. 6AV6352-1MH31-1AA0 AMS Client 5 UI Operating station license for simultaneous use of no more than 5 parallel client sessions. The client license can be installed on more than one PC – only the number of simultaneously active clients is counted. 6AV6352-1MJ31-1AA0 AMS Client 10 UI Operating station license for simultaneous use of no more than 10 parallel client sessions. The client license can be installed on more than one PC – only the number of simultaneously active clients is counted. 6AV6352-1MK31-1AA0 1) The basic price also includes the AMS Reports packages. 2) AMS importer as well as 1 day of consulting for initial design by ETM Consultants (excluding travel expenses) and 5 hours of telephone support within 3 months after delivery. 3) AMS Reports and AMS Importer, and 1 day of consulting for initial conceptualization by ETM consultants (not incl. travel costs). This license does not include any support and cannot be expanded or extended. © Siemens AG 2013 HMI Software SIMATIC ProAgent process diagnostics software SIMATIC ProAgent ■ Overview ■ Benefits • Process error diagnostics software for quick and precise diagnosis of faults/errors in plants and machines for SIMATIC S7 and SIMATIC HMI • Standardized diagnostics concept for various SIMATIC components: optimum interaction of STEP 7 engineering tools and SIMATIC HMI • Standardized user interface • Integral component of Totally Integrated Automation (TIA): increases productivity, minimizes the engineering outlay, reduces the lifecycle costs • ProAgent: - Provides optimum support for plant and machine personnel in respect of troubleshooting and fault rectification - Increases plant availability - Reduces downtimes • No further configuration overhead for diagnostics functionality • Frees up PLC capacity with regard to memory and program execution time • No special operator know-how is required thanks to clearly comprehensible indication of the cause of error ■ Application Increased productivity is being achieved more and more by cutting costs. In this context, the focus is increasingly on maintenance. The emphasis here is on rectifying faults as quickly and efficiently as possible. G_ST80_XX_00367 67(3 Process error diagnostics with ProAgent for WinCC flexible /ProAgent and with the STEP 7 engineering tools Ideally, the operating personnel should also perform part of the maintenance tasks. The operating personnel are on-site, they are familiar with the procedures and can intervene quickly. This saves time and reduces costs. It is precisely here that ProAgent can assist operating personnel in identifying faults quickly, in particular in the automotive and machine tool industries. In the event of a process fault, process fault diagnostics with SIMATIC ProAgent will provide information about the location and cause of that fault and support personnel with troubleshooting. The ProAgent solution has been optimized specifically for use with SIMATIC S7-300/S7-400 and SIMATIC WinAC. It can be used in combination with the S7-PDIAG, S7-GRAPH and S7-HiGraph1) STEP 7 engineering tools. The ProAgent option package features standard displays that are updated with process-specific data during runtime. 1) Process diagnostics with S7-HiGraph in combination with TP/OP/MP 270/277, MP 370/377, and C7636 and PC RT systems. 3B67B;;B 67(3 Process error diagnostics with WinCC/ProAgent and the STEP 7 engineering tools Siemens ST 80 / ST PC · 2013 4/161 4 © Siemens AG 2013 HMI Software SIMATIC ProAgent process diagnostics software SIMATIC ProAgent ■ Function • Context-sensitive diagnostics initiation due to process error message • Output of operands with symbols and comment • Switching is possible between LAD, STL and signal list • Supporting fault rectification with direct process access when using the motion display • Output of the faulty operands directly in the message including address, symbol and comment 1) • Consistency test in RT: Inconsistent diagnostic units are marked with icons. This permits quick locating of faults regarding configured data in the commissioning phase. • Direct, unit-related entry point in the diagnostic display from user displays by using ProAgent functions • Unit or message-related entry to STEP 7 (LAD/STL/FD editor, S7-GRAPH, HW CONFIG (upon system error messages)), supported fully automatically 2) • Unit or message-related entry to STEP 7), supported fully automatically 3) • Graphic display of step sequences (overview display) 4) 4 1) In combination with TP/OP/MP 270/277, MP 370/377, C7 636, WinCC/ProAgent as of V6.0, and WinCC flexible /ProAgent 2) WinCC/ProAgent as of V5.5 and as of WinCC flexible 2007 /ProAgent on PC RT 3) Only WinCC/ProAgent as of V5.5 4) As of WinCC flexible 2007 /ProAgent, WinCC/ProAgent as of V5.6 in combination with S7-GRAPH as of V5.1 (OCX is delivered as of S7-GRAPH 5.1) Standardized user interface with standard displays • Message display • Unit overview • Diagnostics detail display • Motion display • Sequencer operating display The displayed image contents are related to the previously selected units or messages. This means that the proper. contextsensitive diagnostics display can be called up based on a message or a selected technological unit. 4/162 Siemens ST 80 / ST PC · 2013 Message display All of the existing process messages are shown in the message display. Context-sensitive branching to other diagnostic displays is also possible with a selected message. The operating personnel can also take the message directly from the erroneous operands and react immediately without having to perform any other operations on the HMI device. WinCC flexible permits this function on the Windows CE-based devices TP/OP/MP 270/277, MP 370/377, and on PC Runtime systems. The function is available as of version 6.0 for WinCC/ProAgent. Unit overview The units overview displays all technological units and the respective sub-units (system/machine components) in table form. In this display, the user is able to recognize, for example, which operating mode or which status the respective unit is in. The operating mode can be changed by the user if required. Faulty units are marked with attributes. © Siemens AG 2013 HMI Software SIMATIC ProAgent process diagnostics software SIMATIC ProAgent ■ Function (continued) Diagnostics detail display Sequencer operating display The diagnostic detail display shows the faulty operands at the time of origination of a process error. As an option, current status information can also be displayed. The diagnostics results are either displayed in a ladder diagram (LAD), statement list (STL), or in a clearly arranged signal list overview. The output of the operands depends on the display format with symbols and comments from the S7 symbol table. Only the operands that cause the fault are displayed and marked with a highlighted attribute. Switching to a display that calls up the current status of all operands in the controller is also possible. The sequencer operating display supports sequencer control. This makes functions such as initializing and acknowledging sequencers, activating/deactivating individual steps and operating mode settings possible analog to the status/control in S7-GRAPH. The steps are output to a list with step number/name. Attributes for identifying an active/faulty step give the operating personnel an overview of the current status of the step sequence. 4 Motion display Sequencer diagnostic display The motion display is used for supported fault rectification. Every motion line contains a comment line that describes the motion (e.g. x-axis), two actions for implementing the motion, response concerning the actuation of a motion and information on the respectively achieved end positions (max. 16). WinCC flexible/ProAgent and WinCC/ProAgent1) also offer capabilities for graphic monitoring and sequencer diagnostics. This gives the user the ability to monitor active/faulty steps as well as the fault cause, e.g. faulty transition conditions, simultaneously on the HMI device. The motion itself is controlled with softkeys on the side of SIMATIC Panels and Multi Panels. For time-critical motions, the actuation can be done directly through inputs of the controller (depending on the capabilities of the target hardware: 24 V direct keys, DP direct keys via PROFIBUS). 1) WinCC/ProAgent as of V5.6 in combination with S7-GRAPH as of V5.1 (OCX is delivered as of S7-GRAPH 5.1) Siemens ST 80 / ST PC · 2013 4/163 © Siemens AG 2013 HMI Software SIMATIC ProAgent process diagnostics software SIMATIC ProAgent ■ Technical specifications Interfaces • Can be used in conjunction with programmable controllers: • Types of connection WinCC/ProAgent WinCC flexible /ProAgent SIMATIC S7: S7-300/S7-400; WinAC SIMATIC S7 Protocol Suite: MPI, PROFIBUS DP, Industrial Ethernet, TCP/IP SIMATIC S7: S7-300/S7-400; WinAC SIMATIC S7 Protocol Suite: MPI, PROFIBUS DP, PROFINET IO, Industrial Ethernet, TCP/IP Display units Standard images for: Standard displays for easy embedding in user displays, example project for MP 377 3 (de/en/fr) 5 (de/en/fr/it/es) Modification of HMI diagnostics data management in RT WinCC/ProAgent V6.0 and higher No Unit overview Yes Yes Message display Yes Yes Sequencer operating display Yes Yes Diagnostics detail display • Display STL/LAD/signal list • Display of operands with symbol and comment Yes Yes/Yes/Yes Yes Yes/Yes/Yes Yes Yes Criteria analysis When fault occurs/current status/can be archived When fault occurs/current status 6 6 2 16 2 16 de/en/fr; included in scope of delivery de/en/fr/it/es; included in scope of delivery HMI software WinCC V7.0 SP3 (ProAgent V7.0 SP3) WinCC flexible 2008 Operating system: Configuration WinCC/ProAgent V7.0 + SP2: Windows Professional SP3, Windows 7 (32 bit) Ultimate, Business, and Enterprise WinCC flexible /ProAgent 2008 + SP2: Windows XP SP3, Windows 7 Professional, Ultimate, Enterprise Operating system Runtime WinCC/ProAgent V7.0 + SP2: Windows XP Professional SP3, Windows 7 (32 bit) Ultimate, Business and Enterprise, Windows 2003 Server SP2, Windows 2008 Server SP2 WinCC flexible /ProAgent for SIMATIC Panels: WinCC flexible /ProAgent for WinCC flexible Runtime: Windows XP SP3, Windows 7 Professional, Ultimate, Enterprise STEP 7 • S7-GRAPH • S7-PDIAG • S7-HiGraph V5.4 SP4 and higher V5.3 SP6 and higher V5.3 SP3 and higher No V5.3 and higher V5.2 + SP3 and higher V5.1 and higher V5.3 and higher Type of delivery (one license is required for each target hardware) CD-ROM / Runtime license Runtime license Number of languages for online language selection Functionality 4 Motion display • Number of viewable movements • Directions of motion • Number of viewable end positions per movement Documentation In electronic format Requirements 4/164 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 HMI Software SIMATIC ProAgent process diagnostics software SIMATIC ProAgent ■ Ordering data Order No. SIMATIC WinCC/ProAgent Order No. Documentation (must be ordered separately) Software option package for process error diagnostics based on S7 GRAPH V5 and higher and S7 PDIAG V5 and higher; functional enhancement for SIMATIC WinCC; electronic documentation in English, French and German; functions and standard screens for use on a PC (resolution 1024 x 768 pixel) and Panel PC 577/677/ 877 15" (resolution 1024 x 768 pixel) in English, French and German, Runtime license (single license) WinCC version: SIMATIC HMI Manual Collection 6AV6691-1SA01-0AX0 Electronic documentation on CD-ROM 5 languages (English, German, French, Italian and Spanish); contains: all currently available user manuals, device manuals and communication manuals for SIMATIC HMI • V7.0 SP3; for WinCC V7.0 SP3 1) 6AV6371-1DG07-0AX0 Upgrade • to V7.0 SP3 1) 6AV6371-1DG07-0AX4 SIMATIC WinCC flexible /ProAgent Software option package for process error diagnostics based on S7 PDIAG V5.1 and higher, S7 GRAPH V5.2 + SP3 and higher; S7 HiGRAPH V5.3 and higher. Functional enhancement for SIMATIC WinCC flexible; electronic documentation in English, French, German, Italian and Spanish • WinCC flexible /ProAgent for SIMATIC Panels Runtime license (Single License) executable on TP/OP/MP 270/277, Mobile Panel 277 and MP 370/377 • WinCC flexible /ProAgent for WinCC flexible Runtime Runtime license (single license) 4 6AV6618-7DB01-3AB0 6AV6618-7DD01-3AB0 1) Not multi-station-capable Siemens ST 80 / ST PC · 2013 4/165 © Siemens AG 2013 HMI Software Notes 4 4/166 Siemens ST 80 / ST PC · 2013 5 © Siemens AG 2013 PC-based Automation 5/2 SIMATIC Industrial PC 5/3 5/7 5/13 5/20 Rack PC SIMATIC IPC547D SIMATIC IPC647C SIMATIC IPC847C 5/27 5/30 5/36 5/39 5/44 5/47 Box PC SIMATIC IPC227D SIMATIC IPC427D SIMATIC IPC427C SIMATIC IPC627C SIMATIC IPC827C 5/50 5/53 5/58 5/63 5/67 5/71 SIMATIC Panel PC SIMATIC IPC277D SIMATIC IPC477D SIMATIC HMI IPC477C SIMATIC HMI IPC577C SIMATIC HMI IPC677C 5/76 5/77 5/84 5/90 5/167 5/167 5/168 5/168 5/169 5/169 Input and output devices SIMATIC PC keyboard IP65 membrane keyboard, desk version IP65 membrane keyboard, 19" built-in version 19" slide-in keyboard PS/2 with trackball SIMATIC IPC mouse 5/170 5/171 5/171 5/172 5/172 5/173 SITOP power supplies 1-phase, 24 V DC/10 A (SITOP PSU100S) 1-phase, 24 V DC/20 A (SITOP PSU100S) 3-phase, 24 V DC/10 A (SITOP PSU300S) 3-phase, 24 V DC/20 A (SITOP PSU300S) 3-phase, 24 V DC/40 A (SITOP PSU300S) 5/174 24 V DC uninterruptible power supplies 5/176 5/177 5/178 DC UPS with capacitors SITOP UPS500S SITOP UPS500P SIMATIC PC-based controllers SIMATIC WinAC RTX SIMATIC WinAC RTX F SIMATIC WinAC ODK 5/179 5/181 5/91 5/93 5/100 Embedded Controller EC31 Expansion modules 5/183 5/101 5/102 5/103 5/104 5/108 5/109 5/110 5/114 Embedded bundles/Software packages SIMATIC IPC227D bundles SIMATIC IPC427D bundles SIMATIC IPC427C bundles SIMATIC IPC277D bundles SIMATIC IPC477D bundles SIMATIC HMI IPC477C bundles Software packages for SIMATIC IPC and S7-mEC DC UPS with battery modules DC UPS module 6 A, DC UPS module 15 A DC UPS module 40 A, Battery module 1.2 Ah Battery module 2.5 Ah, Battery module 3.2 Ah Battery module 7 Ah, Battery module 12 Ah 5/117 5/117 5/120 5/130 5/134 5/136 5/139 5/143 Industrial monitors and thin clients SIMATIC Industrial Flat Panel MT SIMATIC Industrial Flat Panel SIMATIC Flat Panels SCD desk monitors SCD 19101 SCD monitors 1900 SIMATIC Industrial Thin Client SIMATIC Thin Client 5/146 5/147 5/149 5/150 5/151 5/152 RMOS3 real-time operating system RMOS3 V3.50 real-time operating system RMOS3-GNU V3.0 RMOS3-TCP/IP V3.0 RMOS3-GRAPHX V1.0 BSP SIMATIC IPC V4.0 for RMOS3 5/153 5/155 5/155 5/156 5/161 5/163 5/164 5/165 5/166 Expansion components / accessories SIMATIC IPC CompactFlash SIMATIC IPC (Service) USB FlashDrive PC I/O SIMATIC Panel PC Remote Kit SIMATIC IPC Image & Partition Creator SIMATIC IPC DiagMonitor SIMATIC IPC Remote Manager SIMATIC IPC BIOS Manager 5/182 5/184 5/185 MASTERGUARD power supply 5/186 5/186 5/187 5/188 5/189 5/191 5/192 5/193 5/194 5/196 5/198 5/199 5/201 5/203 5/205 5/206 5/207 Communication – Industrial Ethernet Connection options to SIMATIC IPCs CP 1604 CP 1616 CP 1612 A2 CP 1613 A2 CP 1623 CP 1628 HARDNET-IE S7-REDCONNECT SOFTNET for Industrial Ethernet SOFTNET-IE RNA SOFTNET PN IO OPC server for Industrial Ethernet PN CBA OPC server S7 OPC Redundancy for Industrial Ethernet SNMP OPC server SINEMA server 5/208 5/208 5/209 5/211 5/213 5/215 5/217 5/219 5/221 5/223 5/225 5/227 5/229 5/230 Communication – PROFIBUS Connection options to SIMATIC IPCs CP 5603 CP 5613 A2 CP 5614 A2 CP 5623 CP 5624 CP 5512 CP 5612 CP 5622 CP 5711 SOFTNET for PROFIBUS OPC server for PROFIBUS S7 OPC Redundancy for PROFIBUS Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation SIMATIC Industrial PC Industrial PC ■ Overview Industrial PC Our reliable and innovative industrial PCs are the optimal PC hardware platform for PC-based Automation from Siemens. Rack PC Rack PCs are flexible, high-availability industrial PC systems for powerful yet compact applications using 19" technology. Box PC SIMATIC Box PCs provide mechanical engineers, plant engineers and control cabinet makers with particularly rugged industrial PC systems for use in powerful yet compact applications. 5 Ruggedness and industrial compatibility for 24-hour continuous use in an industrial environment • Compact, space-saving enclosure (Box PC and Panel PC) • Suitable for installing in space-saving control cabinets, only 500 mm deep (Rack PC) • All-metal enclosure with a high degree of electromagnetic compatibility for use in industrial areas and in domestic, business and commercial environments and for a degree of protection up to IP65/NEMA 4 • The mounting position of the devices can be varied by means of wall, portrait or control cabinet mounting (Box PC), rail mounting (SIMATIC IPC427D or IPC227D only) and horizontal or vertical mounting position in the 19" cabinet or with the appropriate kit as an industrial tower PC (Rack PC). • High resistance to shock/vibration thanks to special hard disk mountings, locked connectors, and card retainers • Maintenance-free, due to design without hard disk and fans using SIMATIC CompactFlash cards or solid-state drive (SIMATIC IPC427D/IPC477D and SIMATIC IPC227D/ IPC277D) • Service-friendly, modular device design for replacement of defective components • Integral industrial power supplies (according to NAMUR) for safe power supplies protected against system disturbances • Attractive product design with dirt-repelling fronts and coated surfaces • Dust protection thanks to a pressurized cooling concept, frontmounted fans and dust filters (Rack PC) ■ More information Notes on the scope of delivery Panel PC Microsoft operating systems are pre-installed in an OEM version. SIMATIC Panel PCs are suitable thanks to their high industrial compatibility for use in control cabinets, consoles and control panels, as well as directly on the machine. Typical areas of application can be found in both factory and process automation. The scope of supply also includes: • Recovery CD for simple reinstallation of the operating system (not for Windows Embedded) • Restore DVD (hard disk image) for fast and very easy restoration of the PC delivery status • SIMATIC IPC Documentation and Drivers DVD • Compact Operating Instructions (German/English/French/Spanish/Italian/Chinese) • Electronic manual on IPC Documentation and Drivers DVD (German/English) Industrial monitors and thin clients Flexible operator input concepts can be implemented via Flat Panel monitors or thin clients. These are industry-standard LCD monitors with high-contrast displays that can be located up to 30 m away from the PC, or low-cost, rugged thin clients that offer HMI functionality over the network in larger plants spread over wide areas. Further information can be found in the Internet at: http://www.siemens.com/simatic-ipc Information material for ordering and for downloading is available on the Internet: http://www.siemens.com/simatic/printmaterial 5/2 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation Rack PC Rack PC ■ Overview Rack PCs are flexible, high-availability industrial PC systems for powerful yet compact applications using 19" technology. Three device classes are available for various requirements: SIMATIC IPC547 – maximum performance at an attractive price SIMATIC IPC647 – maximum compactness combined with maximum industrial functionality SIMATIC IPC847 – maximum expandability and industrial functionality Shared industrial functionality • Maximum system performance for complex automation tasks and computationally intensive PC tasks in the industrial environment through use of Intel Core processors • Designed for 24-hour continuous operation • Monitoring and diagnostics functions (e.g. temperature, fan, watchdog) • RAID1 configuration (mirrored drives), optionally in "hot swap" frames • Hard disks with capacities up to 1 TB for large volumes of data • Solid-state drive (SSD) with SLC technology, optional • Compact dimensions for installation in control cabinets only 500 mm deep • Dust protection thanks to overpressure ventilation concept with fan on the front and dust filter • Lockable front panel or front door • Service-friendly equipment design due to prepared telescopic rail mounting • Universal implementation as an industrial workstation or server • Operating system preinstalled and activated for fast startup • Fast restoration of the delivery status of the HDD thanks to restore DVD • High flexibility and expandability of components • PCI and PCI Express expansion slots • Independent industrial product design 5 Siemens ST 80 / ST PC · 2013 5/3 © Siemens AG 2013 PC-based Automation Rack PC Rack PC ■ Overview (continued) SIMATIC IPC547D – maximum performance at an attractive price • Intel Core i processors 2nd generation • Maximum processor performance in maximum configuration without loss of power (throttling) at ambient temperatures of up to 40 °C • Optional RAID5 configuration (striping with parity) in "hot swap" frames • Redundant AC power supply, optional • Low noise output thanks to controlled fans • Status and alarm LEDs at the front for signaling critical system states • Availability for at least 1.5 years • Guaranteed spare parts availability for at least 3 years 5 SIMATIC IPC647C – maximum compactness combined with maximum industrial functionality • Maximum compactness due to 3 free PCI/PCI Express slots for installing long expansion cards and integrated interfaces for communication, e.g. integrated PROFIBUS/MPI or PROFINET interface • High thermal stability up to 50°C even at maximum processor performance • High vibration/shock resistance thanks to special hard disk holders • Intel Core i processors • Enhanced server functionality: Hardware RAID PCIe x8 controller with zero-maintenance cache protection module, SAS hard disks in hot-swap frame with capacities up to 1 TB for large volumes of data • Redundant AC power supply, optional • ECC memory, optional • Service-friendly device design due, for example, to the replacement of filters/fans from the front without the need for tools, or opening of the enclosure with just one screw. • Front LED concept for efficient self-diagnostics, e.g. monitoring of the hard disks in RAID1 configurators, fans or the status display for Ethernet, PROFINET and PROFIBUS. • Integrated PROFIBUS DP/MPI or PROFINET interface (optional) • High continuity of the components/design • Motherboard developed and manufactured by Siemens • Availability for up to 6 years • Guaranteed spare parts availability for at least 5 years 5/4 Siemens ST 80 / ST PC · 2013 SIMATIC IPC847C – maximum expandability and industrial functionality • Maximum expandability due to 11 free PCI/PCI Express slots for installing long expansion cards and integrated interfaces for communication, e.g. integrated PROFIBUS/MPI or PROFINET interface • High thermal stability up to 50°C even at maximum processor performance • High vibration/shock resistance thanks to special hard disk holders • Intel Core i processors • Optional RAID5 configuration (striping with parity) in "hot swap" frames • Extended server functionality: Hardware RAID PCIe x8 controller, SAS hard disks in hot-swap frame with capacities up to 1 TB for large volumes of data • Redundant AC power supply, optional • SATA hard disks with capacities up to 500 GB for large volumes of data • ECC memory, optional • Service-friendly device design due, for example, to the replacement of filters/fans from the front without the need for tools, or opening of the enclosure with just one screw. • Front LED concept for efficient self-diagnostics, e.g. monitoring of the hard disks in RAID1 configurators, fans or the status display for Ethernet, PROFINET and PROFIBUS. • Integrated PROFIBUS DP/MPI or PROFINET interface (optional) • High continuity of the components/design • Motherboard developed and manufactured by Siemens • Availability for up to 6 years • Guaranteed spare parts availability for at least 5 years © Siemens AG 2013 PC-based Automation Rack PC Rack PC ■ Overview (continued) SIMATIC IPC547D SIMATIC IPC647C SIMATIC IPC847C 19" rack 4 HU 2 HU 4 HU Prepared for telescopic rails • • • Horizontal/vertical installation •/• •/- •/• 19" mounting bracket can be removed from outside • • • Tower Kit (optional) • - • Processor • Intel Core i7-2600 (4C/8T, 3.40 GHz) • Intel Core i5-2400 4C/4T, 3.10 GHz) • Intel Pentium G850 (2C/2T, 2.90 GHz) • Intel Core i7-610E (2C/4T, 2.53 GHz) • Intel Core i5-520E (2C/4T, 2.4 GHz) • Intel Core i3-330E (2C/4T, 2.13 GHz) • Intel Core i7-610E (2C/4T, 2.53 GHz) • Intel Core i5-520E (2C/4T, 2.4 GHz) • Intel Core i3-330E (2C/4T, 2.13 GHz) Main memory • 1 GB, expandable up to 32 GB • 1 GB, expandable up to 8 GB • ECC optional • 1 GB, expandable up to 8 GB • ECC optional Slots for expansions (all long, up to 312 mm) • • • • • 2 x PCI • 1 x PCI Express x16 • 7 x PCI • 1 x PCI Express x16 • 3 x PCI Express x4 Design General features 4 x PCI 1 x PCI Express x16 1 x PCI Express x16 (4 lanes) 1 x PCI Express x8 (1 lane) or • 1 x PCI • 1 x PCI Express x8 (4-lane) • 1 x PCI Express x16 or • 7 x PCI • 1 x PCI Express x16 Onboard graphics • 1 x DisplayPort • 1 x DVI-I • 1 x VGA (via adapter cable, optional) • 1 x DVI-I • 1 x VGA (via adapter cable, optional) • 1 x DVI-I • 1 x VGA (via adapter cable, optional) Graphics card (optional) • PCI Express x16 (2 x VGA or 2 x DVI-D) • PCI Express x16 (2 x VGA or 2 x DVI-D) • PCI Express x 16 (2 x VGA or 2 x DVI-D) without • • • Preinstalled and activated, supplied on restore DVD • Windows XP Professional Multi-Language (32-bit) • Windows 7 Ultimate Multi-Language (32/64-bit) • Windows Server 2008 incl. 5 Client Multi-Language (32-bit) • Windows Server 2008 R2 incl. 5 Clients Multi-Language (64-bit) • Windows XP Professional Multi-Language (32-bit) • Windows 7 Ultimate Multi-Language (32/64-bit) • Windows Server 2003 R2 incl. 5 Clients Multi-Language (32-bit) • Windows Server 2008 incl. 5 Clients Multi-Language (32-bit) • Windows Server 2008 R2 incl. 5 Clients Multi-Language (64-bit) • Windows XP Professional Multi-Language (32-bit) • Windows 7 Ultimate Multi-Language (32/64-bit) • Windows Server 2003 R2 incl. 5 Clients Multi-Language (32-bit) • Windows Server 2008 incl. 5 Clients Multi-Language (32-bit) • Windows Server 2008 R2 incl. 5 Clients Multi-Language (64-bit) Order separately - RMOS3 V3.50 RMOS3 V3.50 Project-specific on request • Linux 1) • Other • Linux 1) • Other • Linux 1) • Other PROFIBUS/MPI - 12 Mbit/s (CP 5611-compatible), optional 12 Mbit/s (CP 5611-compatible), optional PROFINET - 3 x RJ45 (CP 1616-compatible), optional 3 x RJ45 (CP 1616-compatible), optional Ethernet 2 x 10/100/1000 Mbit/s 2 x 10/100/1000 Mbit/s 2 x 10/100/1000 Mbit/s USB 2.0 (high current) 11 x, 2 of which at front, 1 x internal 7 x , 2 of which at front, 1 x internal 7 x , 2 of which at front, 1 x internal VGA • optional • optional • optional DVI • • • DisplayPort • - - Operating system Interfaces Siemens ST 80 / ST PC · 2013 5/5 5 © Siemens AG 2013 PC-based Automation Rack PC Rack PC ■ Overview (continued) SIMATIC IPC547D SIMATIC IPC647C SIMATIC IPC847C • • • • • - • • RAID1/5 configuration with onboard RAID •/• •/- • /• Solid-state drive (SSD), SLC • • • Installation at the front in the swap frame - • • RAID1/5 configuration with HW RAID controller PCI x 8 incl. zero maintenance cache protection module -/- •/- • /• DVD-ROM • - • DVD±R/RW • • • AC power supply • • • Redundant (optional) • • • Vibration/shock load during operation 0.2 g / 1 g 0.5 g / 5 g 0.5 g / 5 g Ambient temperature during operation With maximum configuration: 5 ... 40 °C With maximum configuration: 5 ... 50 °C With maximum configuration: 5 ... 50 °C Drives SATA hard disks • Internal installation • Installation at the front in the swap frame • Internal installation in drive holder (shock and vibration-damped) Hard disks SAS Optical drives Ambient conditions 2) • Available - Not available 5 1) Suitable for specific Linux versions in accordance with the specifications of the Siemens manufacturer's declaration "Suitable for Linux", see http://www.siemens.com/simatic-pc/suited-for-linux (Linux is a trademark of Linus Torvald) 2) Restrictions when using DVD±R/RW and hard disks in swap frame. ■ More information Further information can be found in the Internet under: http://www.siemens.com/simatic-pc Information material can be ordered or downloaded from the Internet: http://www.siemens.com/simatic/printmaterial 5/6 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation Rack PC SIMATIC IPC547D ■ Overview ■ Technical specifications SIMATIC IPC547D General features Design 19" rack, 4 HU, externally painted Processor • Intel Core i7-2600 (4C/8T, 3.40 GHz, 8 MB Last Level Cache, Turbo Boost 2.0, EM64T, VT-x/-d, iAMT) • Intel Core i5-2400 (4C/4T, 3.10 GHz, 6 MB Last Level Cache, Turbo Boost 2.0, EM64T, VT-x/-d, iAMT) • Intel Pentium Dual Core G850 (2C/2T, 2.90 GHz, 3 MB Last Level Cache, EM64T, VT) Chipset • Intel Q67 Main memory • • • • From 1 GB DDR3 1333 SDRAM Dual channel support 4 DIMM base Expandable up to 32 GB 1) Spare slots for expansions (all long) • • • • 4 x PCI 1 x PCI Express x16 1 x PCI-Express x16 (4 lanes) 1 x PCI-Express x8 (1 Lane) Graphics • Onboard Intel HD 2000 graphics controller integrated into the processor; Shared Video Memory up to 1.7 GB; up to 2560 x 1600 pixels at 60 Hz image refresh rate and 32-bit colors • PCI Express graphics card (Dual Head: 2 x VGA or 2 x DVI-D) in the PCIe x16 slot; 512 MB; up to 2048 x 1536 pixels at 85 Hz image refresh rate and 32 bit colors (optional) Operating system • without The SIMATIC IPC547D is a rugged industrial PC in 19" rack design (4 HU). It offers: • Maximum performance • Attractive price • Intel Core i technology Preinstalled and activated (supplied on restore DVD): • Windows XP Professional MUI (32-bit) • Windows 7 Ultimate MUI (32/64-bit) • Windows Server 2008 incl. 5 Client MUI (32 bit) • Windows Server 2008 R2 incl. 5 Client MUI (64 bit) MUI (Multilanguage User Interface, 5 languages): English, German, French, Italian, Spanish Project-specific on request: • Linux 2) • Other Power supply • 100 ... 240 V AC, 50 ... 60 Hz, with bridging of short-term power failures: max. 20 ms at 0.85% rated voltage • Redundant 100 ... 240 V AC, 50 ... 60 Hz 1) Memory information: In order to use a memory with more than 4 GB, a 64-bit operating system is required. In the case of configurations with 4 GB, the visible memory can be reduced to about 3.5 GB or less (with 32-bit operating systems). In configurations with 8 GB, the visible memory can be reduced to about 7.5 GB or less. 2) Suitable for specific LINUX versions in accordance with the specifications of the Siemens manufacturer's declaration "Suitable for LINUX", see http://www.siemens.com/simatic-pc/suited-for-linux (LINUX is a trademark of Linus Torvald). Siemens ST 80 / ST PC · 2013 5/7 5 © Siemens AG 2013 PC-based Automation Rack PC SIMATIC IPC547D ■ Technical specifications (continued) SIMATIC IPC547D Drives SIMATIC IPC547D Monitoring functions Hard disk, SATA 3.5" with NCQ technology Solid State Drive, SATA 2.5" with SLC technology Installation in internal drive support • 500 GB • 1 TB • RAID1 3) 1 TB (2 x 1 TB, mirror disks) • 50 GB solid-state drive Installation at the front in swap frame (low profile) • 500 GB • 2 x 500 GB • RAID1 3) 1 TB (2 x 1 TB, mirror disks), "hot swap" • RAID5 3) 2 TB (3 x 1 TB, striping with parity), "hot swap" • 50 GB solid-state drive • RAID1 3) 1 TB (2 x 1 TB, mirror disks), "hot swap" + 50 GB solidstate drive (operating system installed on SSD if configured) DVD-ROM, 5.25", SATA • 16 x (DVD media) • 32 x (CD media) DVD±R/RW, 5.25", SATA • 16 x 24 x 8 x (DVD media) • 48 x 48 x 32 x (CD media) Slots for drives Front: • 3 x 5.25" • 1 x 3.5" Basic functionality Message locally via DiagBase software Temperature When permitted operating temperature range is exceeded Fan Speed monitoring • 1 x front fan • 1 x CPU fan • 1 x power supply fan Watchdog • Monitoring of program execution • Monitoring time can be parameterized in software Monitoring functions via the network SIMATIC IPC DiagMonitor Version V4.3.x.x or higher (optional) Remote monitoring capability for: • Watchdog • Temperature • Fan speed • Battery • Hard disks (SMART) • System/Ethernet Communication: • Ethernet interface (SNMP protocol) • OPC for integration in SIMATIC software • Client server architecture • Structure of log files Internal: • 2 x 3.5" Front LEDs Interfaces 5 Ethernet 2 x Intel Gbit Ethernet (RJ45, teaming-capable) USB 2.0 • 2 x front (high current) • 8 x rear (high current) • 1 x internal (high current), e.g. for USB dongle with optional interlocking Serial 9-pole COM1 (V.24); COM2 (V.24) (optional) Parallel LPT (optional) VGA Optionally via adapter cable DVI-I 1x DisplayPort 1x Keyboard PS/2 Mouse PS/2 Audio 1 x Line In; 1 x Line Out; 1 x Micro 3) SATA RAID controller onboard in Intel Q67 chipset 4) Restrictions in use of optical drives and HDD in swap frames. 5/8 Siemens ST 80 / ST PC · 2013 • • • • POWER (PC switched on) HDD (access to hard disk) TEMP (temperature monitoring) FAN (fan monitoring) Additional HDD alarm LEDs for RAID configurations behind the front flap Ambient conditions Degree of protection IP30 front, IP20 rear according to EN 60529 Dust protection With the front door closed according to IEC 60529 filter class G2 EN 779, 99% of particles > 0.5 mm are filtered Protection class Protection class I according to IEC 61140 Vibration load during operation 4) IEC 60068-2-6, 10 cycles • 20 ... 58 Hz: 0.015 mm • 58 ... 200 Hz: 2 m/s2 (approx. 0.2 g) Shock load in operation 4) IEC 60068-2-27 • Half-sine: 9.8 m/s2, 20 ms (approx. 1 g), 100 shocks per axis © Siemens AG 2013 PC-based Automation Rack PC SIMATIC IPC547D ■ Technical specifications (continued) SIMATIC IPC547D Electromagnetic compatibility (EMC) Emitted interference SIMATIC IPC547D Approvals and safety regulations EN 61000-6-3; EN 61000-6-4; CISPR 22 / EN 55022 Class B; FCC Class A; EN 61000-3-2 Class D; EN 61000-3-3 Immunity to conducted interference on the supply lines • ± 2 kV (IEC 61000-4-4, burst) • ± 1 kV (IEC 61000-4-5, symm. surge) • ± 2 kV (IEC 61000-4-5, asymm. surge) Immunity to interference on signal lines • ±2 kV (IEC 61000-4-4, burst, length > 30 m) • ± 1 kV (IEC 61000-4-4, burst, length < 30 m) • ± 2 kV (IEC 61000-4-5, surge, length > 30 m) Immunity to static discharge • ± 4 kV, contact discharge (IEC 61000-4-2) • ±8 kV, air discharge (IEC 61000-4-2) Immunity to high radio frequency interference • 1 V/m 80% AM; 2 ... 2.7 GHz (IEC 61000-4-3) • 10 V/m 80% AM; 80 MHz ... 1 GHz and 1.4 GHz … 2 GHz (IEC 61000-4-3); • 10 V, 10 kHz ... 80 MHz (IEC 61000-4-6) Immunity to magnetic fields 100 A/m, 50/60 Hz (IEC 61000-4-8) Ambient temperature during operation 5 ... 40 °C Safety regulations IEC 60950-1; UL60950; CSA Approvals cULus 60950 CE mark For use in industrial areas as well as domestic, business and commercial environments: • Emitted interference: EN 61000-6-3:2007 • Noise immunity: EN 61000-6-2:2005 Dimensions and weights Mounting dimensions (W x H x D) in mm 434 x 177 x 446 Weight, approx. 19 kg Note: Limitations for operation of DVD±R/RW Humidity during operation 5 ... 80% at 25 °C (no condensation) Note regarding SIMATIC PC operating system licenses The accompanying operating system license is only valid for installation on the respective supplied SIMATIC IPC. Installation can only be performed on these SIMATIC systems in accordance with Microsoft OEM licensing regulations. Siemens ST 80 / ST PC · 2013 5/9 5 © Siemens AG 2013 PC-based Automation Rack PC SIMATIC IPC547D ■ Ordering data SIMATIC IPC547D Order No. 1) Order No. 6AG4104- 2 7 7 7 7 - 7 7 7 7 Interfaces: 2 x Gbit Ethernet (RJ45), 1 x DisplayPort, 1 x DVI-I, 8 x USB on the rear, 2 x USB on the front, 1 x USB internal, 1 x serial (COM1), 2 x PS/2, audio; 7 slots (all long): 4 x PCI, 1 x PCIe x16, 1 x PCIe x16 (4 lanes), 1 x PCIe x8 (1 lane); mounting locations: 6 (3 x 5.25", 1 x 3.5" externally accessible; 2 x 3.5" internal); temperature and fan monitoring; watchdog; card retainer Processors • Pentium Dual Core G850 (2C/2T, 2.90 GHz, 3 MB Last Level Cache, EM64T, VT) • Core i5-2400 (4C/4T, 3.10 GHz, 6 MB Last Level Cache, Turbo Boost 2.0, EM64T, VT-x/-d, iAMT) • Core i7-2600 (4C/8T, 3.40 GHz, 8 MB Last Level Cache, Turbo Boost 2.0, EM64T, VT-x/-d, iAMT) 5 Drives • 500 GB HDD SATA; internal • 1 TB HDD SATA; internal • RAID1, 1 TB (2 x 1 TB HDD SATA, mirror disks); internal 2) • 50 GB solid-state drive (SLC) SATA; internal • 500 GB HDD SATA in swap frame; front • 2 x 500 GB HDD SATA in swap frame; front • RAID1, 1 TB (2 x 1 TB HDD SATA, mirror disks) in swap frame; for hot swapping; at the front • RAID5, 2 TB (3 x 1 TB HDD SATA, striping with parity) in swap frame; for hot swapping; at the front • 50 GB solid-state drive (SLC) SATA in swap frame; at the front • RAID1, 1 TB (2 x 1 TB HDD SATA, mirror disks) in swap frame; hot swapping; at the front + 50 GB solid-state drive (SLC) SATA in swap frame; at the front (operating system installed on SSD, if configured) Memory configuration • 1 GB DDR3 SDRAM (1 x 1 GB), single channel • 2 GB DDR3 SDRAM (2 x 1 GB), dual channel • 4 GB DDR3 SDRAM (2 x 2 GB), dual channel • 8 GB DDR3 SDRAM 3) (2 x 4 GB), dual channel • 16 GB DDR3 SDRAM 3) (4 x 4 GB), dual channel • 32 GB DDR3 SDRAM 3) (4 x 8 GB), dual channel Removable media • DVD-ROM • DVD±RW Expansions (hardware) • Without expansions (HW); onboard graphics • No expansions (HW); onboard graphics; DVI-I VGA-compliant adapter cable for onboard graphics • Serial (COM2) & parallel (LPT); onboard graphics • Serial (COM2) and parallel (LPT); onboard graphics; DVI-I VGAcompliant adapter cable for onboard graphics • Serial (COM2) & parallel (LPT) + PCIe x16 graphics card (Dual Head: 2 x VGA or 2 x DVI-D), 512 MB A C Operating systems (preinstalled and activated) • Windows XP Professional, MUI (Eng, Ger, Fr, It, Sp), 32-bit, SP3 • Windows 7 Ultimate, MUI (Eng, Ger, Fr, It, Sp), 32 bit, SP1 enclosed • Windows 7 Ultimate, MUI (Eng, Ger, Fr, It, Sp), 64 bit, SP1 enclosed • Windows Server 2008 Standard Edition incl. 5 Client, MUI (Eng, Ger, Fr, It, Sp), 32 bit, SP2 • Windows Server 2008 R2 Standard Edition incl. 5 clients, MUI (Eng, Ger, Fr, It, Sp), 64 bit, SP1 enclosed • Without operating system D A B D E G H P Expansions (software) • SIMATIC IPC DiagMonitor V4.3 software included • SIMATIC IPC Image & Partition Creator V3.2 software included • SIMATIC IPC DiagMonitor V4.3 + Image & Partition Creator V3.2 software included • Without expansions (software) R S T 0 1 2 3 4 5 1) For an up-to-date overview, see the SIMATIC PC online configurator at: www.siemens.com/ipc-configurator 2) Not in combination with redundant power supply 3) Can only be used on 64-bit operating systems 5/10 Siemens ST 80 / ST PC · 2013 SIMATIC IPC547D (continued) 1) Power supply, with country-specific cable: • 100/240 V AC industrial power supply; power cable for Europe • 100/240 V AC industrial power supply; USA power cable • 100/240 V AC industrial power supply; power cable for China • 2 x 100/240 V AC redundant industrial power supply; without power cable 6AG4104- 2 7 7 7 7 - 7 7 7 7 1 2 0 1 2 3 4 B E F P Q X A B C X 0 4 5 6 © Siemens AG 2013 PC-based Automation Rack PC SIMATIC IPC547D ■ Ordering data Order No. Preferred variants (ex-stock) SIMATIC IPC547D • Pentium Dual Core G850 (2C/2T, 2.90 GHz, 3 MB Last Level Cache, EM64T, VT); 500 GB HDD SATA internal; 1 GB DDR3 SDRAM (1 x 1 GB), single channel; DVD-ROM; interfaces: 2 x Gbit Ethernet (RJ45), 1 x serial, 8 x USB rear, 2 x USB front, 1 x USB internal, 2 x PS/2, audio; 100/240 V industrial power supply, power cable for Europe; without operating system • Core i5-2400 (4C/4T, 3.10 GHz, 6 MB Last Level Cache, Turbo Boost 2.0, EM64T, VT-x/-d, iAMT); RAID1, 1 TB (2 x 1 TB HDD SATA, mirror disks) in swap frame, for hot swapping, at the front; 4 GB DDR3 SDRAM (2 x 2 GB) dual channel; DVD±RW; interfaces: 2 x Gbit Ethernet (RJ45), 2 x serial, 1 x parallel, 8 x USB rear, 2 x USB front, 1 x USB internal, 2 x PS/2, Audio; 100/240V industrial power supply, power cable for Europe; without operating system • Core i7-2600 (4C/8T, 3.40 GHz, 8 MB Last Level Cache, Turbo Boost 2.0, EM64T, VT-x/-d, iAMT); RAID1, 1 TB (2 x 1 TB HDD SATA, mirror disks) in swap frame, for hot swapping, at the front; 8 GB DDR3 SDRAM (2 x 4 GB) dual channel; DVD±RW; interfaces: 2 x Gbit Ethernet (RJ45), 2 x serial, 1 x parallel, 8 x USB rear, 2 x USB front, 1 x USB internal, 2 x PS/2, audio; 100/240 V industrial power supply, power cable for Europe, Windows 7 Ultimate MUI (Eng, Ger, Fr, It, Sp), 64-bit, SP1 supplied Order No. Accessories 6AG4104-2AA01-0XX0 6AG4104-2CP22-2XX0 6AG4104-2DP32-2FX0 Memory expansion • 1 GB DDR3 1333 SDRAM, DIMM (1 x 1 GB) • 2 GB DDR3 1333 SDRAM, DIMM, kit for dual-channel technology (2 x 1 GB) • 4 GB DDR3 1333 SDRAM, DIMM, kit for dual-channel technology (2 x 2 GB) • 8 GB DDR3 1333 SDRAM, DIMM, kit for dual-channel technology (2 x 4 GB) 6ES7648-2AJ40-0LA0 6ES7648-2AJ50-0LB0 6ES7648-2AJ60-0LB0 6ES7648-2AJ70-0LB0 Tower Kit For converting the computer into an industrial tower PC 6ES7648-1AA00-0XC0 Retainer for pin assignment of the internal USB port 6ES7648-1AA00-0XK0 Power cable, straight, 3 m long • Austria, Belgium, Finland, France, Germany, Netherlands, Spain, Sweden • United Kingdom • Switzerland • USA • Italy • China 6ES7900-0AA00-0XA0 6ES7900-0BA00-0XA0 6ES7900-0CA00-0XA0 6ES7900-0DA00-0XA0 6ES7900-0EA00-0XA0 6ES7900-0FA00-0XA0 Rack unit for low-profile HDD swap frame for 3.5" hard disk, SATA (without hard disk) 6ES7648-0EG00-1BA0 Expansion components From page 5/153 5 Note: Software Packages with SIMATIC WinCC flexible, SIMATIC WinCC RT Advanced, SIMATIC WinCC, and SIMATIC WinAC RTX (F) can be ordered together with the SIMATIC IPC at favorable prices. More information under "Embedded Bundles / Packages for industrial PCs". Siemens ST 80 / ST PC · 2013 5/11 © Siemens AG 2013 PC-based Automation Rack PC SIMATIC IPC547D ■ Dimensional drawings ■ More information All dimensions in mm. For mounting cut-out see technical specifications. Further information can be found on the Internet at: http://www.siemens.com/simatic-pc 37.5 465.1 176.5 101.6 481.4 G_ST80_XX_00452 489 18.5 14.3 445.5 433.5 Technical data of the telescopic rails 5 Carrying capacity per pair, min. 30 kg Full extension length, min. 470 mm Rail thickness, max. 9.7 mm Fixing screws M5 x 6 mm The fixing screws of the telescopic rails should not project more than 5 mm into the enclosure. The enclosure is prepared for the following telescopic rails: • Rittal: Type 3659.180 for 600 mm cabinet / Type RP 3659.190 for 800 mm cabinet • Schroff: Type 20110-072 5/12 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation Rack PC SIMATIC IPC647C ■ Overview ■ Technical specifications SIMATIC IPC647C General features Design 19" rack, 2 HUs, external coating Processor • Intel Core i7-610E (2C/4T, 2.53 GHz, 4 MB cache, Turbo Boost, VT-d, iAMT, EM64T) • Intel Core i5-520E (2C/4T, 2.4 GHz, 3 MB cache, Turbo Boost, VT-d, iAMT, EM64T) • Intel Core i3-330E (2C/4T, 2.13 GHz, 3 MB cache, EM64T) Chipset Intel QM57 Main memory • • • • Spare slots for expansions (all long) • 2 x PCI • 1 x PCI Express x16 The SIMATIC IPC647C is a very rugged, high-performance industrial PC in 19" rack design (2 HMs) with excellent industrial functionality. It offers: • Extreme compactness • Extreme ruggedness • Intel Core i technology from 1 GB DDR3 1066 SDRAM Dual channel support 2 DIMM slots Expandable up to 8 GB, optional ECC 1) or • 1 x PCI • 1 x PCI Express x8 (4 lane) • 1 x PCI Express x16 Graphics 1) • Onboard Intel GMA HD graphics controller integrated into processor; dynamic video memory; up to 2048 x 1536 pixels with 75 Hz refresh rate and 16-bit colors • PCI Express graphics card (Dual Head: 2 x VGA or 2 x DVI-D via display port adapter) in the PCIe x16 slot; 256 MB; up to 2048 x 1536 pixels with 75 Hz refresh rate and 32-bit colors (optional) Memory information: In order to use a memory with more than 4 GB, a 64-bit operating system is required. In the case of configurations with 4 GB, the visible memory can be reduced to about 3.5 GB or less (with 32-bit operating systems). In configurations with 8 GB, the visible memory can be reduced to about 7.5 GB or less. Siemens ST 80 / ST PC · 2013 5/13 5 © Siemens AG 2013 PC-based Automation Rack PC SIMATIC IPC647C ■ Technical specifications (continued) SIMATIC IPC647C Operating system • without • Preinstalled, activated, and supplied on restore DVD • Windows XP Professional MUI, 32-bit • Windows 7 Ultimate MUI, 32/64-bit • Windows Server 2003 R2 incl. 5 client MUI, 32-bit • Windows Server 2008 incl. 5 client MUI, 32-bit • Windows Server 2008 R2 incl. 5 client MUI, 64-bit MUI: Multi-language User Interface; 5 languages (English, French, German, Italian, Spanish) • Project-specific on request 2) • Other • 100 ... 240 V AC, 50 ... 60 Hz; with bridging of temporary power failures in accordance with NAMUR: max. 20 ms at 0.85% rated voltage • Redundant 100 ... 240 V AC, 50 ... 60 Hz Power supply SIMATIC IPC647C Interfaces PROFINET 3 x RJ45 (CP 1616-compatible), optional PROFIBUS/MPI 12 Mbit/s (isolated, compatible with CP 5611), optional Ethernet 2 x 10/100/1000 Mbit/s (RJ45, teaming-capable) USB 2.0 • 2 x front (high current) • 4 x rear (high current) • 1 x internal (high current), e.g. for USB dongle with optional lock Serial • 9-pin COM1 (V.24) • 9-pin COM2 (V.24) Parallel LPT1 VGA 1x Keyboard PS/2 Mouse PS/2 Audio 1 x Line Out; 1 x Micro Drives Hard disks: SATA 3.5" or SAS 3.5" Mounted in internal shock/ vibration-resistant drive cage • 250 GB • 500 GB • 2 x 500 GB • 500 GB RAID1 3), (2 x 500 GB, mirror disks) Mounted in front drive cage in swap frame (low profile) • 250 GB • 500 GB • 2 x 500 GB • 500 GB RAID1 3), (2 x 500 GB, mirror disks), "hot swap" • 1 TB RAID1, (2 x 1 TB HDD SAS, mirror disks), "hot swap"; RAID controller in PCIe x8 slot with zero-maintenance cache protection module 5 Solid-State Drive (SSD) (2.5" SATA) Installed internally or front-mounted in removable frame • 50 GB (SLC), optional DVD+/-R/RW, slimline • 8 x 8 x 6 x (DVD media) • 24 x 24 x 24 x (CD media) Slots for drives Front: • 2 x low profile swap frames (for 3.5" HDD) • 1 x 12.7 mm slimline (for ODD or CF drive) Internal: • 2 x 3.5" as an alternative to swap frames (in the optional, shock and vibration-damped drive cage) 5/14 Siemens ST 80 / ST PC · 2013 2) Suitable for specific LINUX versions in accordance with the specifications of the Siemens manufacturer's declaration "Suitable for LINUX", see (LINUX is a trademark of Linus Torvald). 3) SATA RAID controller on board in Intel chipset © Siemens AG 2013 PC-based Automation Rack PC SIMATIC IPC647C ■ Technical specifications (continued) SIMATIC IPC647C Monitoring functions SIMATIC IPC647C Ambient conditions Basic functionality Message locally via DiagBas e software Degree of protection IP41 at the front, IP20 at the rear acc. to EN 60529 Temperature • Overshoot/undershoot of permissible operating temperature range • Messages can be evaluated by the application program Dust protection with front door closed: G2 EN 779, 99% of particles > 0.5 mm are held back Protection class Fan • Speed monitoring • 2 x enclosure fan (front) • 1 x power supply fan Protection class I in accordance with IEC 61140 Vibration load during operation DIN EN 60068-2-6, 10 cycles Watchdog • Monitoring of program execution • Monitoring time can be parameterized in software • Restart can be parameterized in the event of a fault • Messages can be evaluated by the application program Monitoring functions via the network SIMATIC IPC DiagMonitor (optional) Version 4.3 and higher Remote monitoring capability for: • Watchdog • Temperature • Fan speed • Hard disk monitoring (SMART) • Redundant power supply (module) • System/Ethernet monitoring (Heartbeat) Communication: • Ethernet interface (SNMP protocol) • OPC for integration in SIMATIC software • Configuration of client/server architectures • Structure of log files Front LEDs • POWER (internal power supply unit, PC switched on) • HARDDISK (access to hard disk) • ETHERNET1 (Ethernet status, "Heartbeat") • ETHERNET2 (Ethernet status, "Heartbeat") • PROFIBUS/MPI (PROFIBUS status) • SF PROFINET (PROFINET status) • WATCHDOG (ready/fault indication) • TEMP (temperature status) • FAN (fan speed monitoring) • HDD1 ALARM (hard disk alarm in conjunction with RAID1 and monitoring software) • HDD2 ALARM (hard disk alarm in conjunction with RAID1 and monitoring software) Internal mounting of the hard disk drives in optional, internal drive cage: • 10 ... 58 Hz: 0.0375 mm; • 58 ... 500 Hz: 5 m/s2 (approx. 0.5 g) Note: There are limitations when DVD+/-RW and HDD are operated in a swap frame Shock loading during operation DIN EN 60068-2-27, IEC 60068-2-29 Internal mounting of the hard disk drives in optional, internal drive cage: • Half-sine: 50 m/s2, 30 ms (ca. 5 g), 100 shocks per axis Note: There are limitations when DVD+/-RW and HDD are operated in a swap frame Electromagnetic compatibility (EMC) Emitted interference (AC) EN 61000-6-3, EN 61000-3-3, EN 61000-3-2 Class D; FCC Class A Immunity to conducted interference on the supply lines ± 2 kV (IEC 61000-4-4, burst) ± 1 kV (IEC 61000-4-5, symm. surge) ± 2 kV (IEC 61000-4-5, asymm. surge) Immunity to interference on signal lines ± 1 kV (IEC 61000-4-4, burst, length < 30 m) ± 2 kV (IEC 61000-4-4, symm. surge, length > 30 m) ± 2 kV (IEC 61000-4-5, asymm. surge, length > 30 m) Siemens ST 80 / ST PC · 2013 5/15 5 © Siemens AG 2013 PC-based Automation Rack PC SIMATIC IPC647C ■ Technical specifications (continued) SIMATIC IPC647C Immunity to static discharge ±6 kV, contact discharge (IEC 61000-4-2) ±8 kV, air discharge (IEC 61000-4-2) Immunity to high radio frequency interference • 1 V/m 80% AM 1 kHz; 2 ... 2.7 GHz (IEC 61000-4-3) • 10 V/m 80% AM 1 kHz; 80 MHz - 1 GHz and 1.4 GHz - 2 GHz (IEC 61000-4-3); • 10 V, 10 kHz to 80 MHz (IEC 61000-4-6) Immunity to magnetic fields 100 A/m, 50/60 Hz (IEC 61000-4-8) Ambient temperature during operation 5 … 50 °C Note: There are limitations when DVD+/-RW and HDD are operated in a swap frame Relative operating humidity 5 ... 85 % at 30 °C (no condensation) Approvals and safety regulations Safety regulations IEC 60950-1 Second Edition, EN 60950-1, UL 60950, CSA C22.2 No 60950 Approvals cULus 60950, KCC Marine approval (only for configurations with CompactFlash or SSD memory) • • • • CE mark Use in industry: • Noise immunity: EN 61000-6-2:2005 5 GL –- Germanische Lloyd BV – Bureau Veritas LR – Lloyds Register of Shipping ABS – American Bureau of Shipping • DNV – Det Norske Veritas • NKK – Nippon Kaiji Kyokai Use in domestic environments: • Emitted interference: EN 61000-6-3:2007 Dimensions and weights Mounting dimensions (W x H x D, in mm) 430 x 88 x 445 Note regarding SIMATIC PC operating system licenses The accompanying operating system license is only valid for installation on the respective supplied SIMATIC IPC. Installation can only be performed on these SIMATIC systems in accordance with Microsoft OEM licensing regulations. 5/16 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation Rack PC SIMATIC IPC647C ■ Ordering data SIMATIC IPC647C Order No. 1) Order No. 6AG4112- 1 7 7 7 7 - 7 7 7 7 Interfaces: 2 x 10/100/1000 Mbps Ethernet (RJ45); 1 x graphic (DVI-I); 2 x COM; 1 x LPT; 2 x PS/2; 4 x USB 2.0 at rear, 2 x USB 2.0 at front; 1 x USB 2.0 internal; audio; temperature and fan monitoring, watchdog; card retainer Processor/motherboard • Core i3-330E (2C/4T, 2.13 GHz, 3 MB cache), motherboard without fieldbus • Core i3-330E (2C/4T, 2.13 GHz, 3 MB cache), motherboard with PROFIBUS/MPI • Core i3-330E (2C/4T; 2.13 GHz, 3 MB cache), motherboard with PROFINET (3 x RJ45, CP 1616-compatible) 2) • Core i5-520E (2C/4T, 2.4 GHz, 3 MB cache, TB, iAMT, VT), motherboard without fieldbus • Core i5-520E (2C/4T, 2.4 GHz, 3 MB cache, TB, iAMT, VT), motherboard with PROFIBUS/MPI • Core i5-520E (2C/4T; 2.4 GHz, 3 MB cache, TB, iAMT, VT), motherboard with PROFINET (3 x RJ45, CP 1616-compatible) 2) • Core i7-610E (2C/4T, 2.53 GHz, 4 MB cache, TB, iAMT, VT), motherboard without field bus • Core i7-610E (2C/4T, 2.53 GHz, 4 MB cache, TB, iAMT, VT), motherboard with PROFIBUS/MPI • Core i7-610E (2C/4T; 2.53 GHz, 4 MB cache, TB, iAMT, VT), motherboard with PROFINET (3 x RJ45, CP 1616-compatible) 2) Hard disks: • 250 GB HDD SATA; 0.5 g vibration, 5 g shock, internal • 500 GB HDD SATA; 0.5 g vibration, 5 g shock, internal • 2 x 500 GB HDD SATA; 0.5 g vibration, 5 g shock, internal • RAID1 500 GB (2 x 250 GB HDD SATA, mirror disks); 0.5 g vibration, 5 g shock, internal • 250 GB HDD SATA in swap frame; front • 500 GB HDD SATA in swap frame; front • 2 x 500 GB HDD SATA in swap frame; front • RAID1 500 GB (2 x 250 GB HDD SATA) in swap frame, for hot swapping; front • 50 GB SSD (SLC) SATA, internal • 50 GB SSD (SLC) SATA in swap frame; front • RAID1 1 TB (2 x 1 TB HDD SAS) in swap frame, for hot-swapping, front; PCIe x8 RAID controller with zero-maintenance cache protection module in PCIe x16 slot 3) SIMATIC IPC647C (continued) 1) 6AG4112- 1 7 7 7 7 - 7 7 7 7 Memory configuration: • 1 GB DDR3 SDRAM (1 x 1 GB), single channel • 2 GB DDR3 SDRAM (1 x 2 GB), single channel • 4 GB DDR3 SDRAM (2 x 2 GB), dual channel • 6 GB DDR3 SDRAM (1 x 2 GB, 1 x 4 GB), dual channel • 8 GB DDR3 SDRAM (2 x 4 GB), dual channel • 2 GB DDR3 SDRAM (2 x 1 GB), dual channel • 4 GB DDR3 SDRAM (2 x 2 GB), dual channel • 8 GB DDR3 SDRAM (2 x 4 GB), dual channel G H J Swap media: • CompactFlash drive, at front • DVD±RW • without swap medium K L M N P R A B C D H 0 1 2 3 4 5 6 7 0 1 8 Bus module / hardware expansion • Bus modules 3 slots: 2 x PCI; 1 x PCIe x16; without hardware expansions • Bus modules 3 slots: 2 x PCI; 1 x PCIe x16; DVI-VGA adapter (1 x VGA) for onboard graphics • Bus modules 3 slots: 2 x PCI; 1 x PCIe x16 assigned; + graphics card PCIe x16, 2 x DP (2 x DVI-D via 2 x DP-DVI adapters) • Bus modules 3 slots: 2 x PCI; 1 x PCIe x16 assigned; + graphics card PCIe x16, 2 x DP (2 x VGA via 2 x DP-VGA adapters) • Bus modules 3 slots: 1 x PCI, 1 x PCIe x8 (4-lane); 1 x PCIe x16; without HW expansions • Bus modules 3 slots: 1 x PCI; 1 x PCIe x8 (4-lane); 1 x PCIe x16; DVI-VGA adapter (1 x VGA) for onboard graphics • Bus modules 3 slots: 1 x PCI; 1 x PCIe x8 (4-lane); 1 x PCIe x16 assigned; + graphics card PCIe x16, 2 x DP (2x DVI-D via 2x DP-DVI adapters) • Bus modules 3 slots: 1 x PCI; 1 x PCIe x8 (4-lane); 1 x PCIe x16 assigned; + graphics card PCIe x16, 2 x DP (2x VGA via 2x DP-VGA adapters) 0 1 2 3 5 4 5 6 7 K M P S T U 1) For an up-to-date overview, see the SIMATIC PC online configurator at: www.siemens.com/ipc-configurator 2) Not in combination with Windows Server operating systems. 3) Not in combination with graphics card, Windows XP, Windows 7 (32-bit), without removable media. Siemens ST 80 / ST PC · 2013 5/17 © Siemens AG 2013 PC-based Automation Rack PC SIMATIC IPC647C ■ Ordering data SIMATIC IPC647C 1) (continued) Order No. Operating system (preinstalled and activated) • Windows XP Professional, MUI (Eng, Ger, Fr, It, Sp), SP3, 32-bit • Windows 7 Ultimate, MUI (Eng, Ger, Fr, It, Sp), 32-bit, SP1 included • Windows 7 Ultimate, MUI (Eng, Ger, Fr, It, Sp), 64-bit, SP1 included • Windows Server 2003 R2 Standard Edition incl. 5 clients, MUI (Eng, Fr, Ger, It, Sp), SP2, 32-bit, SP2 • Windows Server 2008 Standard Edition incl. 5 clients, MUI (Eng, Fr, Ger, It, Sp), SP2, 32-bit • Windows Server 2008 R2 Standard Edition incl. 5 clients, MUI (Eng, Fr, Ger, It, Sp), SP2, 64-bit, SP1 included • Without operating system Expansion (software) • SIMATIC IPC DiagMonitor 4.3 included • SIMATIC IPC Image Creator software 3.2 included • SIMATIC IPC DiagMonitor 4.3 and Image Creator Software 3.2 included • Without software 5 Order No. 6AG4112- 1 7 7 7 7 - 7 7 7 7 Memory expansion • 1 GB DDR3 1066 SDRAM, DIMM • 2 GB DDR3 1066 SDRAM, DIMM • 4 GB DDR3 1066 SDRAM, DIMM • 1 GB DDR3 1066 SDRAM, DIMM, ECC • 2 GB DDR3 1066 SDRAM, DIMM, ECC • 4 GB DDR3 1066 SDRAM, DIMM, ECC B E F N P Q X B C X For an up-to-date overview, see the SIMATIC PC online configurator at: www.siemens.com/ipc-configurator 0 1 2 6ES7648-2AJ40-0KA0 6ES7648-2AJ50-0KA0 6ES7648-2AJ60-0KA0 6ES7648-2AJ40-1KA0 6ES7648-2AJ50-1KA0 6ES7648-2AJ60-1KA0 Hard disk slide-in unit for swap frame SIMATIC PC accessories, slide-in HDD swap frame, low-profile, for 3.5" hard disk, serial ATA / SAS (without hard disk) 6ES7648-0EG00-1BA0 Filter mats for SIMATIC IPC647C (packing unit: 10 units) A5E02396171 Power cable, straight, 3 m long • Austria, Belgium, Finland, France, Germany, Netherlands, Spain, Sweden • United Kingdom • Switzerland • USA • Italy • China A Power supply, with country-specific cable: • 100/240°V°AC industrial power supply with Namur; power cable for Europe • 100/240 V AC industrial power supply with Namur; power cable for United Kingdom • 100/240 V AC industrial power supply with Namur; power cable for Switzerland • 100/240 V AC industrial power supply with Namur; power cable for USA • 100/240 V AC industrial power supply with Namur; power cable for Italy • 100/240 V AC industrial power supply with Namur; power cable for China • 100/240 V AC redundant power supply with Namur; without power cable 1) Accessories 6ES7900-0AA00-0XA0 6ES7900-0BA00-0XA0 6ES7900-0CA00-0XA0 6ES7900-0DA00-0XA0 6ES7900-0EA00-0XA0 6ES7900-0FA00-0XA0 USB retainer for pin assignment of the internal USB port 6ES7648-1AA00-0XK0 Expansion components From page 5/153 Communication products From page 5/186 RMOS real-time operating system From page 5/146 3 4 5 6 Note: Software Packages with SIMATIC WinCC flexible, WinCC RT Advanced, SIMATIC WinCC, and SIMATIC WinAC RTX (F) can be ordered together with the SIMATIC IPC at favorable prices. More information under "Embedded bundles / Packages for industrial PCs". 5/18 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation Rack PC SIMATIC IPC647C ■ Dimensional drawings ■ More information All dimensions in mm. For mounting cut-out see technical specifications. Further information can be found in the Internet under: http://www.siemens.com/simatic-pc 481.4 87.6 5.7 76.2 465 G_ST80_XX_00453 444.6 429.9 487.1 8.2 Technical data of the telescopic rails Carrying capacity per pair, min. 30 kg Full extension length, min. 470 mm Rail thickness, max. 9.7 mm Fixing screws M5 x 6 mm 5 The fixing screws of the telescopic rails should not project more than 5 mm into the enclosure. The enclosure is prepared for the following telescopic rails: • Rittal: Type 3659.180 for 600 mm cabinet / Type RP 3659.190 for 800 mm cabinet Siemens ST 80 / ST PC · 2013 5/19 © Siemens AG 2013 PC-based Automation Rack PC SIMATIC IPC847C ■ Overview ■ Technical specifications SIMATIC IPC847C General features Design 19" rack, 4 HU, externally painted Processor • Intel Core i7-610E ( 2C/4T, 2.53 GHz, 4 MB Cache, Turbo Boost, VT-d, iAMT, EM64T) • Intel Core i5-520E (2C/4T, 2.4 GHz, 3 MB cache, Turbo Boost, VT-d, iAMT, EM64T) • Intel Core i3-330E (2C/4T, 2.13 GHz, 3 MB cache, EM64T) Chipset Intel QM57 Main memory • • • • Spare slots for expansions (all long) • 7 x PCI • 1 x PCI Express x16 • 3 x PCI Express x4 The SIMATIC IPC847C is a very robust, high-performance industrial PC in 19" rack design (4 HU) with excellent industrial functionality. It offers: • Maximum expandability • Extreme ruggedness • Intel Core i technology or • 7 x PCI • 1 x PCI Express x16 Graphics 1) 5 5/20 Siemens ST 80 / ST PC · 2013 from 1 GB DDR3 1066 SDRAM Dual channel support 2 DIMM slots Expandable up to 8 GB 1) • Onboard Intel GMA HD graphics controller integrated into processor; dynamic video memory; up to 2048 x 1536 pixels with 75 Hz refresh rate and 16-bit colors • PCI Express graphics card (Dual Head: 2 x VGA or 2 x DVI-D via display port adapter) in the PCIe x16 slot; 256 MB; up to 2048 x 1536 pixels with 75 Hz refresh rate and 32-bit colors (optional) Memory information: In order to use a memory with more than 4 GB, a 64-bit operating system is required. In the case of configurations with 4 GB, the visible memory can be reduced to about 3.5 GB or less (with 32-bit operating systems). In configurations with 8 GB, the visible memory can be reduced to about 7.5 GB or less. © Siemens AG 2013 PC-based Automation Rack PC SIMATIC IPC847C ■ Technical specifications (continued) SIMATIC IPC847C Operating system • without • Preinstalled and activated / supplied on restore DVD • Windows XP Professional MUI, 32-bit • Windows 7 Ultimate MUI, 32/64-bit • Windows Server 2003 R2 incl. 5 client MUI, 32-bit • Windows Server 2008 incl. 5 client MUI, 32-bit • Windows Server 2008 R2 incl. 5 client MUI, 64-bit MUI: Multi-language User Interface; 5 languages (English, French, German, Italian, Spanish) • Project-specific on request • Linux 2) • Other Power supply • 100 ... 240 V AC, 50 ... 60 Hz with bridging of temporary power failures in accordance with NAMUR: max. 20 ms at 0.85% rated voltage • Redundant 100 ... 240 V AC, 50 ... 60 Hz SIMATIC IPC847C Interfaces PROFINET 3x RJ45 (CP 1616-compatible), optional PROFIBUS/MPI 12 Mbit/s (isolated, compatible with CP 5611), optional Ethernet 2 x 10/100/1000 Mbit/s (RJ45, teaming-capable) USB 2.0 • 2 x front (high current) • 4 x rear (high current) • 1 x internal (high current), e.g. for USB dongle Serial • 9-pin COM1 (V.24) • 9-pin COM2 (V.24) Parallel LPT1 VGA 1x Keyboard PS/2 Mouse PS/2 Audio 1 x Line Out; 1 x Micro Drives Hard disks SATA 3.5" or SAS 3.5" Installation in internal drive cage • 250 GB Can be installed in internal shock and vibration-damped drive cage (optional) • 250 GB • 500 GB • 2 x 500 GB • 500 GB RAID13), (2 x 500 GB, mirror disks) Installation in front drive cage in swap frame • 250 GB • 2 x 500 GB • 500 GB RAID13), (2 x 500 GB, mirror disks), "hot swap" • 1 TB RAID53), (3 x 500 GB, striping with parity), "hot swap" • 1 TB RAID1, (2 x 1 TB, mirror disks), "hot swap"; PCIe x8 RAID controller in PCIe x16 slot • 1.8 TB RAID5, (3 x 1 TB, striping with parity), "hot swap"; controller with zero-maintenance cache protection module in PCIe x16 slot • 50 GB SATA solid-state drive (SLC) Solid-State Drive (SSD) (2.5" SATA) Installed internally or front-mounted in removable frame 50 GB (SLC), optional DVD-ROM, 5.25", SATA • 16 x (DVD media) • 48 x (CD media) DVD+/-R/RW, 5.25", SATA • 16 x 16 x 12 x (DVD media) • 48 x 32 x 48 x (CD media) Floppy disk - Slots for drives Front: • 3 x 5.25" and 2 x 3.5" 5 Internal: • 2 x 3.5" (in the optional, vibration-damping drive cage) 2) Suitable for specific LINUX versions in accordance with the specifications of the Siemens manufacturer's declaration "Suitable for LINUX", see http://www.siemens.com/simatic-pc/suited-for-linux (LINUX is a trademark of Linus Torvald). 3) SATA RAID controller on board in Intel chipset Siemens ST 80 / ST PC · 2013 5/21 © Siemens AG 2013 PC-based Automation Rack PC SIMATIC IPC847C ■ Technical specifications (continued) SIMATIC IPC847C Monitoring functions SIMATIC IPC847C Ambient conditions Basic functionality Message locally via DiagBase software Degree of protection IP41 at the front, IP20 at the rear acc. to EN 60529 Temperature • Overshoot/undershoot of permissible operating temperature range • Messages can be evaluated by the application program Dust protection With front door closed: G2 EN 779, 99% of particles > 0.5 mm are held back Protection class Fan • Speed monitoring • 2 x enclosure fans • 1 x fan power supply Protection class I in accordance with IEC 61140 Vibration load during operation DIN EN 60068-2-6, 10 cycles Watchdog • Monitoring of program execution • Monitoring time can be parameterized in software • Restart can be parameterized in the event of a fault • Messages can be evaluated by the application program Monitoring functions via the network SIMATIC PC DiagMonitor (optional) Internal mounting of the hard disk drives in optional, internal drive cage: • 10 ... 58 Hz: 0.0375 mm • 58 ... 500 Hz: 5 m/s2 (approx. 0.5 g) Permanently installed internal hard disk drives: • 10 ... 58 Hz: 0.019 mm • 58 ... 500 Hz: 3 m/s2 (approx. 0.3 g) Remote monitoring capability for: • Watchdog • Temperature • Fan speed • Hard disk monitoring (SMART) • System/Ethernet monitoring (Heart Beat) Communication: • Ethernet interface (SNMP protocol) • OPC for integration in SIMATIC software • Configuration of client/server architectures • Structure of log files Front LEDs 5 5/22 • POWER (internal power supply unit, PC switched on) • HARDDISK (access to hard disk) • ETHERNET1 (Ethernet status, "Heartbeat") • ETHERNET2 (Ethernet status, "Heartbeat") • PN / MPI/DP (PROFINET/PROFIBUS status) • WATCHDOG (ready/fault indication) • TEMP (temperature status) • FAN (fan speed monitoring) • HDD1 ALARM (hard disk alarm in conjunction with RAID and monitoring software) • HDD2 ALARM (hard disk alarm in conjunction with RAID and monitoring software) • HDD3 ALARM (hard disk alarm in conjunction with RAID and monitoring software) Siemens ST 80 / ST PC · 2013 Note: There are limitations when DVD+/-RW and HDD are operated in a swap frame Shock loading during operation DIN EN 60068-2-27, IEC 60068-2-29 Internal mounting of the hard disk drives in optional, internal drive cage: • Half-sine: 50 m/s2, 30 ms (approx. 5 g), 100 shocks per axis • Permanently installed internal hard disk drives: 30 m/s2, 30 ms (approx. 3 g) Note: There are limitations when DVD+/-RW and HDD are operated in a swap frame © Siemens AG 2013 PC-based Automation Rack PC SIMATIC IPC847C ■ Technical specifications (continued) SIMATIC IPC847C Electromagnetic compatibility (EMC) Emitted interference (AC) EN 61000-6-3 FCC Class A EN 61000-3-2 Class D and EN 61000-3-3 Immunity to conducted interference on the supply lines ± 2 kV (IEC 61000-4-4, burst) ± 1 kV (IEC 61000-4-5, symm. surge) ± 2 kV (IEC 61000-4-5, asymm. surge) Immunity to interference on signal lines ± 1 kV (IEC 61000-4-4, burst, length < 30 m) ± 2 kV (IEC 61000-4-4, symm. surge, length > 30 m) ± 2 kV (IEC 61000-4-5, asymm. surge, length > 30 m) Immunity to static discharge ±6 kV, contact discharge (IEC 61000-4-2) ±8 kV, air discharge (IEC 61000-4-2) Immunity to high radio frequency interference • 1 V/m 80% AM; 2-2.7 GHz (IEC 61000-4-3) • 10 V/m 80% AM; 80 MHz to 1 GHz and 1.4 GHz and 2 GHz (IEC 61000-4-3); • 10 V, 10 kHz to 80 MHz (IEC 61000-4-6) Immunity to magnetic fields 100 A/m, 50/60 Hz (IEC 61000-4-8) Ambient temperature during operation 5 ... 50 °C Relative operating humidity 5 ... 80% at 25 °C (no condensation) Note: There are limitations when using DVD-ROM / DVD+/-RW and SAS HDD in swap frames 5 Approvals and safety regulations Safety regulations IEC 60950-1 Second Edition, EN 60950-1:2006, UL 60950-1 Second Edition CSA C22.2 No 60950-1-07 Second Edition Approvals cULus 60950-1 Second Edition, KCC CE mark • Emitted interference: EN 61000-6-3:2007 • Noise immunity: EN 61000-6-2:2005 Dimensions and weights Mounting dimensions (W x H x D, in mm) 430 x 177 x 448 Note regarding SIMATIC PC operating system licenses The accompanying operating system license is only valid for installation on the respective supplied SIMATIC IPC. Installation can only be performed on these SIMATIC systems in accordance with Microsoft OEM licensing regulations. Siemens ST 80 / ST PC · 2013 5/23 © Siemens AG 2013 PC-based Automation Rack PC SIMATIC IPC847C ■ Ordering data SIMATIC IPC847C Order No. 1) Order No. 6AG4114- 1 7 7 7 7 - 7 7 7 7 Interfaces: 2 x 10/100/1000 Mbps Ethernet (RJ45); 1 x graphic (DVI-I); 2 x COM; 1 x LPT; 2 x PS/2; 4 x USB 2.0 at rear, 2 x USB 2.0 at front, 1x USB 2.0 internal; audio; temperature and fan monitoring, watchdog; 5 Processor, motherboard: • Core i3-330E (2C/4T, 2.13 GHz, 3 MB cache), motherboard without fieldbus • Core i3-330E (2C/4T, 2.13 GHz, 3 MB cache), motherboard with PROFIBUS/MPI • Core i3-330E (2C/4T; 2.13 GHz, 3 MB cache), motherboard with PROFINET (3 x RJ45, CP 1616-compatible) 2) • Core i5-520E (2C/4T, 2.4 GHz, 3 MB cache, TB, iAMT, VT), motherboard without fieldbus • Core i5-520E (2C/4T, 2.4 GHz, 3 MB cache, TB, iAMT, VT), motherboard with PROFIBUS/MPI • Core i5-520E (2C/4T; 2.4 GHz, 3 MB cache, TB, iAMT, VT), motherboard with PROFINET (3 x RJ45, CP 1616-compatible) 2) • Core i7-610E (2C/4T, 2.53 GHz, 4 MB cache, TB, iAMT, VT), motherboard without field bus • Core i7-610E (2C/4T, 2.53 GHz, 4 MB cache, TB, iAMT, VT), motherboard with PROFIBUS/MPI • Core i7-610E (2C/4T; 2.53 GHz, 4 MB cache, TB, iAMT, VT), motherboard with PROFINET (3 x RJ45, CP 1616-compatible) 2) 5/24 Siemens ST 80 / ST PC · 2013 G H J K L M N P R SIMATIC IPC847C (continued) 1) Hard disks: • 250 GB HDD SATA; 0.5 g vibration, 5 g shock, internal • 500 GB HDD SATA; 0.5 g vibration, 5 g shock, internal • 2 x 500 GB HDD SATA; 0.5 g vibration, 5 g shock, internal • RAID1 500 GB (2 x 500 GB HDD SATA, mirror disks); 0.5 g vibration, 5 g shock, internal • 250 GB HDD SATA; 0.3 g vibration, 3 g shock, internal • 250 GB HDD SATA in swap frame; front • 500 GB HDD SATA in swap frame; front • 2 x 500 GB HDD SATA in swap frame; front • RAID1 500 GB (2 x 500 GB HDD SATA) in swap frame, for hot swapping; front • RAID5 1 TB (3 x 500 GB HDD SATA) in swap frame, for hot swapping; front • 50 GB SSD (SLC) SATA, internal • 50 GB SSD (SLC) SATA in swap frame; front • RAID1 1 TB (2 x 1 TB HDD SAS) in swap frame, for hot-swapping, front; PCIe x8 RAID controller with zero-maintenance cache protection module in PCIe x16 slot 3) • RAID5 1.8 TB (3 x 1 TB HDD SAS) in swap frame, for hot-swapping, front; PCIe x8 RAID controller with zero-maintenance cache protection module in PCIe x16 slot 3) Memory configuration: • 1 GB DDR3 SDRAM (1 x 1 GB), single channel • 2 GB DDR3 SDRAM (1 x 2 GB), single channel • 4 GB DDR3 SDRAM (2 x 2 GB), dual channel • 6 GB DDR3 SDRAM (1 x 2 GB, 1 x 4 GB), dual channel • 8 GB DDR3 SDRAM (2 x 4 GB), dual channel • 2 GB DDR3 SDRAM (2 x 1 GB), dual channel • 4 GB DDR3 SDRAM (2 x 2 GB), dual channel • 8 GB DDR3 SDRAM (2 x 4 GB), dual channel 6AG4114- 1 7 7 7 7 - 7 7 7 7 A B C D G H K M P R S T U V 0 1 2 3 4 5 6 7 1) For an up-to-date overview, see the SIMATIC PC online configurator at: www.siemens.com/ipc-configurator 2) Not in combination with Windows Server 2008 R2, Windows Server 2008 and Windows Server 2003 R2 3) Not in combination with graphics card, Windows XP, Windows 7 (32-bit), without removable media. © Siemens AG 2013 PC-based Automation Rack PC SIMATIC IPC847C ■ Ordering data SIMATIC IPC847C 1) (continued) Swap media: • DVD-ROM • DVD+/-RW • Without swap medium Bus module / hardware expansion • Bus module, 8 slots: 7 x PCI, 1 x PCIe x16; without hardware expansions • Bus module, 8 slots: 7 x PCI; 1x PCIe x16; DVI-VGA adapter (1 x VGA) for onboard graphics • Bus module, 8 slots: 7x PCI; 1x PCIe x16 assigned; + graphics card PCIe x16, 2 x DP (2x DVI-D via 2x DP-DVI adapters) • Bus module, 8 slots: 7x PCI; 1x PCIe x16 assigned; + graphics card PCIe x16, 2 x DP (2x VGA via 2x DP-VGA adapters) • Bus module, 11 slots: 7 x PCI, 1 x PCIe x16, 3 x PCIe x4; without hardware expansions • Bus module, 11 slots: 7x PCI, 1x PCIe x16, 3x PCIe x4; + DVI-VGA adapter (VGA) for onboard graphics • Bus module, 11 slots: 7x PCI; 1x PCIe x16 assigned, 3x PCIe x4; + graphics card PCIe x16, 2 x DP (2x DVI-D via 2x DP-DVI adapters) • Bus module, 11 slots: 7x PCI; 1x PCIe x16 assigned; 3x PCIe x4; + graphics card PCIe x16, 2x DP (2x VGA via 2x DP-VGA adapters) Order No. Order No. 6AG4114- 1 7 7 7 7 - 7 7 7 7 1 2 8 0 1 2 3 4 5 6 7 SIMATIC IPC847C 1) (continued) 6AG4114- 1 7 7 7 7 - 7 7 7 7 Operating system (preinstalled and activated) • Windows XP Professional, MUI (Eng, Ger, Fr, It, Sp), 32-bit, SP3 • Windows 7 Ultimate, MUI (Eng, Ger, Fr, It, Sp), 32-bit, SP1 included • Windows 7 Ultimate, MUI (Eng, Ger, Fr, It, Sp), 64-bit, SP1 included • Windows Server 2003 R2 Standard Edition incl. 5 clients, MUI (Eng, Fr, Ger, It, Sp), 32-bit, SP2 • Windows Server 2008 Standard Edition incl. 5 clients, MUI (Eng, Ger, Fr, It, Sp), 32-bit, SP2 • Windows Server 2008 R2 Standard Edition incl. 5 clients, MUI (Eng, Ger, Fr, It, Sp), 64-bit, SP1 enclosed • Without operating system Software expansion • SIMATIC IPC DiagMonitor 4.3 included • SIMATIC IPC Image Creator software 3.2 included • SIMATIC IPC DiagMonitor 4.3 & Image Creator software 3.2 included • Without software Power supply, country-specific cable • 100/240 V AC industrial power supply with Namur; power cable for Europe • 100/240 V AC industrial power supply with Namur; power cable for United Kingdom • 100/240 V AC industrial power supply with Namur; power cable for Switzerland • 100/240 V AC industrial power supply with Namur; power cable for USA • 100/240 V AC industrial power supply with Namur; power cable for Italy • 100/240 V AC industrial power supply with Namur; power cable for China • 100/240 V AC industrial redundant power supply unit with Namur; without power cable 1) B E F N P Q X A B C X 0 1 2 3 4 5 6 For an up-to-date overview, see the SIMATIC PC online configurator at: http://www.siemens.com/ipc-configurator Siemens ST 80 / ST PC · 2013 5/25 5 © Siemens AG 2013 PC-based Automation Rack PC SIMATIC IPC847C ■ Ordering data Order No. Order No. Accessories Memory expansion • 1 GB DDR3 1066 SDRAM, DIMM • 2 GB DDR3 1066 SDRAM, DIMM • 4 GB DDR3 1066 SDRAM, DIMM • 1 GB DDR3 1066 SDRAM, DIMM, ECC • 2 GB DDR3 1066 SDRAM, DIMM, ECC • 4 GB DDR3 1066 SDRAM, DIMM, ECC Power cable, straight, 3 m long • Austria, Belgium, Finland, France, Germany, Netherlands, Spain, Sweden • United Kingdom • Switzerland • USA • Italy • China 6ES7648-2AJ40-0KA0 6ES7648-2AJ50-0KA0 6ES7648-2AJ60-0KA0 6ES7648-2AJ40-1KA0 6ES7648-2AJ50-1KA0 6ES7648-2AJ60-1KA0 Tower Kit for converting the computer into an industrial tower PC 6ES7648-0EG00-1BA0 Hard disk slide-in unit for swap frame SIMATIC PC accessories, slide-in unit for low-profile HDD swap frame, for 3.5" hard disk, SATA / SAS (without hard disk) Filter mats For Rack PC 847B and IPC847C Packing unit 10 units A5E01064980 6ES7900-0AA00-0XA0 6ES7900-0BA00-0XA0 6ES7900-0CA00-0XA0 6ES7900-0DA00-0XA0 6ES7900-0EA00-0XA0 6ES7900-0FA00-0XA0 6ES7648-1AA00-0XD0 Retainer for pin assignment of the internal USB port 6ES7648-1AA00-0XK0 Expansion components From page 5/153 Communication products From page 5/186 RMOS real-time operating system From page 5/146 Note: Software Packages with SIMATIC WinCC flexible, WinCC RT Advanced, SIMATIC WinCC, and SIMATIC WinAC RTX (F) can be ordered together with the SIMATIC IPC at favorable prices. More information under "Embedded Bundles / Packages for industrial PCs". ■ Dimensional drawings All dimensions in mm. For mounting cut-out see technical specifications. 101.6 5 176.5 481.4 465.1 *B67B;;B 492 448 Further information can be found in the Internet under: Siemens ST 80 / ST PC · 2013 470 mm Rail thickness, max. 9.7 mm Fixing screws M5 x 6 mm The enclosure is prepared for the following telescopic rails: • Rittal: Type 3659.180 for 600 mm cabinet / Type RP 3659.190 for 800 mm cabinet • Schroff: Type 20110-072 ■ More information 5/26 30 kg Full extension length, min. The fixing screws of the telescopic rails should not project more than 5 mm into the enclosure. 430 http://www.siemens.com/simatic-pc Technical data of the telescopic rails Carrying capacity per pair, min. © Siemens AG 2013 PC-based Automation Box PC Box PC ■ Overview SIMATIC Box PCs provide mechanical engineers, plant engineers and control cabinet makers with particularly rugged industrial PC systems for use in powerful yet compact applications. The following device classes are available for various requirements: • SIMATIC IPC227 (Nanobox PC): The compact embedded IPC – maintenance-free and dust-proof with versatile mounting • SIMATIC IPC427 (Microbox PC): The powerful embedded IPC – maintenance-free with versatile configuration • SIMATIC IPC627/IPC827 (Box PC): The high-end IPC – with maximum performance, functional scope, and expansion capability Shared industrial functionality: • Extreme compactness • Certification for global marketing • System-tested with SIMATIC components • High vibration/shock load during operation • Wide operational temperature range • Robust data storage with CompactFlash/CFast or Solid-State Drive (SSD) • Integrated PROFIBUS or PROFIBUS/MPI interface (optional) • Varied mounting possibilities for flexibility with installation • Designed for 24-hour continuous operation • Integrated parameterizable monitoring functions (temperature, fan, watchdog) • High service friendliness • Operating system preinstalled and activated for fast startup • Motherboard developed and manufactured by Siemens • Availability for 3 to 6 years • Repairs and spare parts service for 5 years • High continuity of the components/design • Installation and software compatible with predecessor model • Long-term availability of PC components from the Intel embedded line SIMATIC IPC227 (Nanobox PC): The compact embedded IPC – maintenance-free and dustproof with versatile mounting • Maximum compactness with approx. 1 liter enclosure volume with integrated industrial power supply for minimum space requirements in the control cabinet • Maximum flexibility thanks four mounting options and interfaces on one side suitable for every installation situation • Optimum variety of interfaces due to a large number of integrated interfaces such as selectable serial ports (RS 232/RS 485/CAN) and 2 x teaming-capable Gigabit LAN • Maximum industrial functionality due to closed enclosure for optimum dust protection and non-volatile retentive memory • Further device options for optimum adaptation to the application with additional PCIe slot or RS 232 interfaces or digital I/O Siemens ST 80 / ST PC · 2013 5/27 5 © Siemens AG 2013 PC-based Automation Box PC Box PC ■ Overview (continued) SIMATIC IPC427 (Microbox PC): The powerful embedded IPC – maintenance-free with versatile configuration • Fan-free operation • High performance with maximum compactness and ruggedness for direct installation in the machine • Optimized for embedded applications • Flexibility expandable using one or two PCIe I/O cards (optional) • Flexible installation options due to DIN rail/wall/front upright mounting, even outside a control cabinet • NVRAM for retentive data storage (optional) SIMATIC IPC627/IPC827 (Box PC): The high-end IPC – with maximum performance, functional scope, and expansion capability • Maximum system performance for complex measuring, control and visualization tasks • High flexibility with expansion slots and integral interfaces • Flexible, space-saving installation with mounting brackets or portrait assembly kits • Rugged design for direct installation in the machine • RAID1 controller onboard • Maximum processor performance up to ambient temperature of 55 °C • High system availability • Battery-backed SRAM as memory for WinAC data • 2 x 7-segment display and 2 signal LEDs (freely programmable) SIMATIC IPC227D (Nanobox PC) SIMATIC IPC427D (Microbox PC) SIMATIC IPC427C (Microbox PC) SIMATIC IPC627C (Box PC) SIMATIC IPC827C (Box PC) Rail or wall mounting • • • - - Wall or portrait mounting • Also: Side mounting • • • • Processor • Intel Atom E620 600 MHz • Intel Atom E640 1.0 GHz • Intel Atom E660 1.3 GHz • Intel Core i73517UE, 1.7 GHz, 4 MB SLC • Intel Core i33217UE, 1.6 GHz, 3 MB SLC • Intel Celeron 827E 1.4 GHz, 1.5 MB SLC • Intel Core2 Duo 1.2 GHz, 800 MHz FSB, 3 MB SLC • Intel Core2 Solo 1.2 GHz, 800 MHz FSB, 3 MB SLC • Intel Celeron M 1.2 GHz, 800 MHz FSB, 1 MB SLC • Intel Core i7-620E, 2.53 GHz, 2 cores, 4 threads, 4 MB cache, TB, HT, VT-x, VT-d • Intel Core i3-330E, 2.13 GHz, 2 cores, 4 threads, 3 MB cache, HT, VT-x • Intel Celeron P4505, 1.86 GHz, 2 cores, 2 MB cache • Intel Core i7-620E, 2.53 GHz, 2 cores, 4 threads, TB, HT, VT-x, VT-d, AMT 4 MB cache • Intel Core i3-330E, 2.13 GHz, 2 cores, 4 threads, HT, VT-x, 3 MB cache • Intel Celeron P4505, 1.86 GHz, 2 cores, 2 MB cache Main memory 512 MB, 1 GB, 2 GB 1 GB, 2 GB, 4 GB, 8 GB 1 GB, 2 GB, 4 GB 1 GB, expandable up to 8 GB, optional ECC 1 GB, expandable up to 8 GB, optional ECC Static RAM 512 KB 512 KB 2 MB 2 MB 2 MB Free slots for expansions 1 x PCIe with PCIe enclosure option Up to 2 x PCIe (enclosure option) Up to 3 x PCI-104 (with expansion frame) 2 x PCI or 1 x PCI-Express x16 / 1 x PCI (175 mm / 265 mm) 3 x PCI (290/290/240 mm), 1 PCI-Express x (185 mm) 1 x PCI-Express x16 (240 mm) Graphics Onboard Onboard Onboard Onboard Onboard Design General features 5 5/28 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation Box PC Box PC ■ Overview (continued) SIMATIC IPC227D (Nanobox PC) SIMATIC IPC427D (Microbox PC) SIMATIC IPC427C (Microbox PC) SIMATIC IPC627C (Box PC) SIMATIC IPC827C (Box PC) Operating system without • • • • • Preinstalled and activated / supplied on restore CD • Windows Embedded Standard 2009 (CF card ≥ 2 GB, SSD, hard disk) • Windows XP Professional MUI (SSD, hard disk) • Windows Embedded Standard 7, 32 bit (CF card ≥ 4 GB, SSD, hard disk) • Windows 7 Ultimate MUI, 32 bit (SSD, hard disk) • Windows 7 Ultimate MUI • Windows Embedded Standard 7 in combination with CF card ≥ 4 GB, solid-state drive, or hard drive • Windows Embedded Standard 2009, in combination with CF card ≥ 2 GB, solidstate drive, or hard drive • Windows XP Professional Multi-Language; in combination with solid-state drive or hard drive • Windows 7 Ultimate MUI • Windows Embedded Standard 7 • Windows XP Professional MUI • Windows 7 Ultimate 32-bit MUI • Windows 7 Ultimate 64-bit MUI • Windows Embedded Standard 2009 English on 8 GB CompactFlash • Windows XP Professional MUI • Windows 7 Ultimate 32-bit MUI • Windows 7 Ultimate 64-bit MUI • Windows Embedded Standard 2009 English on 8 GB CompactFlash Order separately RMOS3 V3.50 RMOS3 V3.50 RMOS3 V3.50 RMOS3 V3.50 RMOS3 V3.50 Project-specific on request • Linux 1) • Other • Linux 1) • Other • Linux 1) • Other • Linux 1) • Other • Linux 1) • Other PROFINET onboard - 3 x RJ45 (CP 1616 compatible) onboard, optional 3 x RJ45 (CP 1616 compatible) onboard, optional 3 x RJ45 (CP 1616 compatible) onboard, optional 3 x RJ45 (CP 1616 compatible) onboard, optional PROFIBUS/MPI - 12 Mbps (compatible with CP 5622), optional 12 Mbps (CP 5611compatible), optional 12 Mbps (CP 5611compatible) onboard, optional 12 Mbps (CP 5611compatible) onboard, optional Ethernet 2 x 10/100/ 1000 Mbps 2 x 10/100/ 1000 Mbps 2 x 10/100/1000 Mbps 2 x 10/100/ 1000 Mbps 1 x 10/100/ 1000 Mbps USB 2.0 (high current) 4x 4 x USB 3.0 4x 4x 4x VGA, LVDS, DVI, DPP 1 x DVI-D • 1 x DVI-I (DVI and VGA) • 1 x DisplayPort 1 x DVI-I (DVI and VGA) 1 x DVI-I (DVI and VGA) 1 x DVI-I (DVI and VGA) Hard disks 1 x 2.5" (optional) 1 x 2.5" (optional) 1 x 2.5" (optional) • 1 x 3.5" • 2 x 2.5" • RAID1/2 x 2.5" • 1 x 3.5" • 2 x 2.5" • RAID1/2 x 2.5" Solid-state drive 1 x 2.5" SATA (optional) 1 x 2.5" SATA (optional) 1 x 2.5" SATA (optional) 1 x 2.5" SATA (optional) 1 x 2.5" SATA (optional) FlashDrive 1 x CF externally accessible • 1 x CFast externally accessible • 1 x CFast internal, in place of HDD, SSD (optional) • 1 x CF externally accessible • 1 x CF internal, in place of HDD, SSD (optional) • 1 x CF at the front, externally accessible • 1 x CF internal, in place of HDD (optional) 1 x CF at the front, externally accessible Optical drives - - - DVD R/W DVD R/W Vibration/shock load during operation 1 g / 15 g (with FlashDrive) 1 g / 15 g (with FlashDrive) 1 g / 15 g (with FlashDrive) 1g/5g 1g/5g Ambient temperature during operation 0 °C … 50 °C (with FlashDrive) 0 °C … 40 °C (with hard disk) With maximum configuration: 0 ... 50/55 ºC (with FlashDrive) With maximum configuration: 0 ... 50/55 ºC (with FlashDrive) With maximum configuration: 5 ... 45 °C With maximum configuration: 5 ... 45 °C 5 ... 40 ºC (with hard disk) 5 ... 40 ºC (with hard disk) 5 ... 50/55 °C (with 20/10 W load on PCI/PCI-Express bus) 5 ... 50/55 °C (with 20/10 W load on PCI/PCI-Express bus) Interfaces Drives Ambient conditions • Available - Not available 1) Suitable for specific Linux versions in accordance with the specifications of the Siemens manufacturer's declaration "Suitable for Linux", see http://www.siemens.com/simatic-pc/suited-for-linux (Linux is a trademark of Linus Torvald). ■ More information Further information can be found on the Internet at: http://www.siemens.com/simatic-pc Information material can be ordered or downloaded from the Internet: http://www.siemens.com/simatic/printmaterial Siemens ST 80 / ST PC · 2013 5/29 5 © Siemens AG 2013 PC-based Automation Box PC SIMATIC IPC227D ■ Overview ■ Technical specifications SIMATIC IPC227D General features 5 SIMATIC IPC227D (Nanobox PC): The compact embedded IPC – maintenance-free and dust-proof with versatile mounting • Maximum compactness with approx. 1 liter enclosure volume or more with integrated industrial power supply for minimum space requirements in the control cabinet • Maximum flexibility thanks four mounting options and interfaces on one side suitable for every installation situation • Optimum variety of interfaces due to a large number of integrated interfaces such as a selectable serial port (RS 232/RS 485/CAN) and 2 x teaming-capable Gigabit LAN • Maximum industrial functionality due to closed enclosure for optimum dust protection and non-volatile retentive memory • Further device options for optimum adaptation to the application with additional PCIe slot or R S232 interfaces or digital I/O Design Rail, wall, portrait or side mounting Processor • Intel Atom E620 600 MHz, 512 MB RAM • Intel Atom E640 1.0 GHz, 1 GB RAM • Intel Atom E660 1.3 GHz, 2 GB RAM Chipset Intel Controller Hub EG20T Buffered MRAM optional, 512 KB, of which 128 KB can be written within the buffer time Free slots for expansions Optional PCIe expansion slot Graphics • Integrated into Intel Atom CPU E6xx • 8 to 256 MB (shared memory), 1920 x 1200, 60 Hz, 32-bit colors Operating system • Without • Windows Embedded Standard 2009 preinstalled, in combination with CF card or solid-state drive or hard drive (optional) • Windows XP Professional MUI preinstalled (in combination with solidstate drive or hard drive; MUI: Multi Language User Interface) (optional) • Windows Embedded Standard 7, 32-bit, preinstalled, in combination with CF card or solid-state drive or hard drive (optional) • Windows 7 Ultimate MUI 32 bit preinstalled (in combination with solidstate drive or hard drive; MUI: Multi Language User Interface) (optional) • Linux 1) (project-specific, on request) • RMOS (project-specific on request) • Others on request project-specifically Design Rail, wall, portrait or side mounting Power supply • 24 V DC (20.4 V ... 28.8 V) • Isolated • With buffering of temporary power failures: max. 10 ms • Line side switch • With power failure indication by means of Power Fail signal 1) 5/30 Siemens ST 80 / ST PC · 2013 Suitable for specific LINUX versions in accordance with the specifications of the Siemens manufacturer's declaration "Suitable for LINUX", see http://www.siemens.com/simatic-pc/suited-for-linux (LINUX is a trademark of Linus Torvald). © Siemens AG 2013 PC-based Automation Box PC SIMATIC IPC227D ■ Technical specifications (continued) SIMATIC IPC227D Drives Flash drive SIMATIC IPC227D Monitoring functions Optional; replaceable, accessible, diagnosable • 2 GB • 4 GB • 8 GB • 16 GB • Processor temperature • Motherboard Temperature Messages can be evaluated by the application program Solid-state drive (SSD) Optional • 50 GB SATA, High Endurance, 2.5" • 80 GB SATA, Standard, 2.5" • Monitoring of program execution • Monitoring time can be parameterized in software • Can be parameterized for a fault or restart Hard disk Optional • 250 GB SATA Messages can be evaluated by the application program CD-ROM Via USB (not included in scope of delivery) DVD-RW Via USB (not included in scope of delivery) Floppy disk Via USB (not included in scope of delivery) Watchdog Monitoring functions via the network Remote monitoring capability for: • Watchdog • Temperature • Mass memory monitoring (SMART) • System/Ethernet monitoring (Heart Beat) • Runtime meter Interfaces PROFINET PROFINET RT via Standard Ethernet controller PROFIBUS/MPI - Ethernet • 2 x 10/100/1000 Mbps (RJ 45) • Two independent Intel Controllers: Intel 82574L / Intel Controller Hub EG20T • With teaming function USB V2.0: 4 x Serial COM1 (V.24), optional COM2-4 DVI-I 1 x DVI-D Keyboard Via USB (not included in scope of delivery) Mouse Via USB (not included in scope of delivery) • DiagBase • SIMATIC IPC DiagMonitor Communication: • Ethernet interface (SNMP protocol) • OPC for integration in SIMATIC software • Configuration of client/server architectures • Structure of log files Ambient conditions Degree of protection to EN 60529 (front/rear) IP40 Vibration load during operation Devices without hard disk: • Requirements according to: IEC 61131-2 • Tested according to: IEC 60068-2-6, Test Fc • 10-58: 0.0375 mm • 58-200: 9.8 m/s2 • 10 x /axis Devices with hard disk: • Requirements according to: IEC 61131-2 • Tested according to: IEC 60068-2-6, Test Fc • 10-58: 0.0375 mm • 58-200: 4.9 m/s2 • 10 x /axis Shock loading during operation Devices without hard disk: • Requirements according to: IEC 61131-2 • Tested according to: IEC 60068-2-27, Test Ea • 150 m/s2, 30 ms shock duration Devices with hard disk: • Requirements according to: IEC 61131-2 • Tested according to: IEC 60068-2-27, Test Ea 50 m/s2, 30 ms shock duration Moist heat With CompactFlash card/SSD: 95 % With hard disk: 80 % Ambient temperature during operation 0 °C up to 50 °C Siemens ST 80 / ST PC · 2013 5/31 5 © Siemens AG 2013 PC-based Automation Box PC SIMATIC IPC227D ■ Technical specifications (continued) SIMATIC IPC227D Electromagnetic compatibility (EMC) SIMATIC IPC227D Approvals Emitted interference EN 55022 Class B Interference immunity, burst EN 61000-6-2 or IEC 61131-2: • 2 kV - tested acc. to IEC 61000-4-4 • 1 kV symmetrical / 2 kV asymmetrical - tested acc. to IEC 61000-4-5 Interference immunity, surge • 1 kV to IEC 61000-4-5; symmetrical • 2 kV to IEC 61000-4-5; asymmetrical Marine approval Only for configurations with CompactFlash or SSD memory • • • • • • GL – Germanische Lloyd BV – Bureau Veritas LR – Lloyds Register of Shipping ABS – American Bureau of Shipping DNV – Det Norske Veritas NKK – Nippon Kaiji Kyokai Device versions Basic version Width x Height x Depth: approx. 191 x 100 x 60 mm ESD interference immunity According to NAMUR Recommendation NE 21 and EN 61000-6-2: • 6 kV contact discharge - tested acc. to IEC 61000-4-2 • 8 kV air discharge - tested acc. to IEC 61000-4-2 COM • 3 additional, integrated serial interfaces (COM2-4); only sending/receiving of data • Width x Height x Depth: approx. 191 x 100 x 89 mm Immunity to high radio frequency interference According to EN 61000-6-2 or IEC 61131-2: • Interference immunity 80 ... 1000 MHz: 10 V/m with 80% AM (1 kHz); tested acc. to IEC 61000-4-3; • 1.4 GHz ... 2 Hz: 10 V/m with 50% pulse modulation; tested according to IEC 61000-4-3 IO • 4 digital inputs/outputs each, 24 V, integrated • Width x Height x Depth: approx. 191 x 100 x 89 mm PCIe • 1 PCIe (x1) slot, integrated • Width x Height x Depth: approx. 191 x 187 x 89 mm Immunity to high-frequency current feed Acc. to NAMUR Recommendation NE 21 and EN 61000-6-2 or IEC 61131-2: • 10 kHz ... 80 MHz: 10 V with 80% AM (1 kHz) tested acc. to IEC 61000-4-6 Immunity to magnetic fields Acc. to NAMUR Recommendation NE 21 and EN 61000-6-2 or IEC 61131-2: • 50/60 Hz; 100 A/m rms value tested acc. to IEC 61000-4-8 Release for individual order variants: See releases in the ordering procedure. 5 5/32 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation Box PC SIMATIC IPC227D ■ Ordering data SIMATIC IPC227D Order No. Order No. 6ES7647- 8 A 7 7 7 - 7 7 7 7 Atom E620 (600 MHz), 512 MB RAM, without drive, with CF slot, COM1: RS232, without operating system, device version: Base, DIN rail, 1 x DVI-D graphics interface 2 x 10/100/1000 Mbps Ethernet RJ45 4 x USB V2.0 (high current) CompactFlash slot 24 V DC industrial power supply Processors / memory configuration / NVRAM • Atom E620 (600 MHz), 512 MB RAM • Atom E620 (600 MHz), 512 MB RAM, NVRAM • Atom E640 (1.0 GHz), 1 GB RAM • Atom E640 (1.0 GHz), 1 GB RAM, NVRAM • Atom E660 (1.3 GHz), 2 GB RAM • Atom E660 (1.3 GHz), 2 GB RAM, NVRAM Drives • Without drive, with CF slot • 250 GB HDD SATA • 50 GB Solid-State Drive SATA (High Endurance) • 80 GB Solid-State Drive SATA (Standard) • 2 GB SIMATIC IPC CompactFlash • 4 GB SIMATIC IPC CompactFlash • 8 GB SIMATIC IPC CompactFlash • 16 GB SIMATIC IPC CompactFlash COM interface • COM1: RS232 • COM1: RS485 • COM1: CAN Operating system • Without operating system • Windows Embedded Standard 2009 preinstalled (CF from 2 GB/SSD/HD) • XP Prof. MUI preinstalled on SSD/HD • Windows Embedded Standard 7 (32-bit) preinstalled (CF from 4 GB/SSD/HD) • Windows 7 (32-bit) MUI preinstalled on SSD/HD 6ES7647- 8 A 7 7 7 - 7 7 7 7 SIMATIC IPC227D Software bundles • Without RTX/HMI software • RTX: WinAC RTX 2010 • RTX-F: WinAC RTX F 2010 • HMI: WinCC RT Advanced 128 PT • HMI: WinCC RT Advanced 512 PT • HMI: WinCC RT Advanced 2048 PT • HMI/RTX: RT 128 PT • HMI/RTX: RT 512 PT • HMI/RTX: RT 2048 PT • HMI/RTX-F: RT 128 PT • HMI/RTX-F: RT 512 PT • HMI/RTX-F: RT 2048 PT A A B C F G H M N P R S T Device versions • Device version: Base line • Device version: PCIe (1 slot) • Device version: COM (COM2-4: RS232) • Device version: IO (4x dig. in/out each) B E F G H A B D E Mounting accessories • Standard mounting rail • Wall mounting • Portrait mounting • Side mounting 0 1 3 1 2 3 4 Release for individual order variants: See releases in the ordering procedure. 4 5 6 7 8 Accessories Cable strain relief set for IPC227D Packing unit: 5 units 6ES7648-1AA50-0XL0 Dust protection set for IPC227D 6ES7648-1AA50-0XG0 5 0 1 2 0 1 2 3 4 Siemens ST 80 / ST PC · 2013 5/33 © Siemens AG 2013 PC-based Automation Box PC SIMATIC IPC227D ■ Dimensional drawings All dimensions in mm. For mounting cut-out see technical specifications. 46 28 4.8 21.5 4.8 19 21 220 231.5 198 220 231.5 20.3 14.5 15 197 76.6 56 2.5 105 SIMATIC IPC227D basic unit, portrait mounting 93.1 G_ST80_XX_00475 100 90.6 G_ST80_XX_00474 60 62 2 100 105 SIMATIC IPC227D COM version, portrait mounting 5 60 SIMATIC IPC227D basic unit, standard rail mounting 5/34 Siemens ST 80 / ST PC · 2013 100 50 8.5 SIMATIC IPC227D COM version, standard rail mounting G_ST80_XX_00465 8.5 G_ST80_XX_00464 50 100 90.6 © Siemens AG 2013 PC-based Automation Box PC SIMATIC IPC227D ■ Dimensional drawings (continued) ■ More information 76.6 56 4.8 21 Further information can be found on the Internet at: http://www.siemens.com/simatic-pc 20.3 220 198 231.5 14.5 G_ST80_XX_00476 90.6 93.1 2.5 187 192 SIMATIC IPC227D PCIe version, portrait mounting 5 8.5 G_ST80_XX_00473 93.5 167 90.6 SIMATIC IPC227D PCIe version, standard rail mounting Siemens ST 80 / ST PC · 2013 5/35 © Siemens AG 2013 PC-based Automation Box PC SIMATIC IPC427D ■ Overview SIMATIC IPC427D (Microbox PC): The powerful embedded IPC – maintenance-free with versatile configuration Ready-to-run, complete solutions (software is already installed and preconfigured) for visualization and automation in connection with WinCC RT Advanced and/or WinAC RTX: • Ultra-compact • Maintenance-free • Third generation Intel Core i technology ■ Technical specifications SIMATIC IPC427D Design • DIN rail mounting • Wall mounting • Portrait mounting • Intel Celeron 827E 1.4 GHz, 1.5 MB SLC • Intel Core i3-3217UE 1.6 GHz, 3 MB SLC • Intel Core i7-3517UE 1.7 GHz, 4 MB SLC Processor SIMATIC IPC427D USB stick General features External, can be connected via USB port Interfaces Serial • COM1 (RS 232) • COM2 (RS 232); optional Graphics • DVI-I: Can be used as DVI or VGA • DPP++: Display port, DVI via DPP-to-DVI adapter USB Memory module without ECC: • 1 GB DDR3-SDRAM SODIMM • 2 GB DDR3-SDRAM SODIMM • 4 GB DDR3-SDRAM SODIMM • 8 GB DDR3-SDRAM SODIMM 4 x USB 3.0, max. 2 high-current at the same time, downward-compatible with USB 2.0/1.1 Ethernet Memory module with ECC: • 4 GB DDR3-ECC SODIMM • 8 GB DDR3-ECC SODIMM • 2 x RJ45 (10/100/1000 Mbps) teaming-capable or • 1 x RJ45 (10/100/1000 Mbps) with PROFINET versions PROFIBUS DP 12 Mbps (isolated, compatible with CP 5622), optional Free slots for expansions Up to 2 x PCIe cards, depending on enclosure design PROFINET 3 x RJ45 (10/100 Mbps), CP 1616 onboard, optional Graphics • Integrated Intel HD2000 or HD4000 • DVI resolution of 640 x 480 pixels up to 1920 x 1200 pixels • Maximum display port resolution 1920 x 1200 pixels • Graphics memory is occupied in the main memory (UMA dynamic) CAN interface Optional Keyboard, mouse Connection via USB port Main memory 5 Power supply 24 V DC (-20%/+20%) max. 4 A Rated conditions Fan-free operation Advanced device functions Temperature • When permitted operating temperature range is exceeded • Warnings can be analyzed by the application program (local, via LAN) Watchdog • Monitoring function for program execution • Restart can be parameterized in the event of a fault • Warnings can be analyzed by the application program (local, via LAN) LED display 4 LEDs for displaying system status, 3 of these can be programmed by the user Short-term voltage dip Up to 15 ms buffer time at full load Buffer memory 512 KB MRAM optional Operating systems Available • without • Windows Embedded Standard 7 • Windows 7 Ultimate MUI Project-specific • Linux • QNX • VxWorks Drives and storage media CFast card • • • • Hard disk • 2.5", 1 x ≥ 250 GB, SATA Solid-state drive (SSD) • 1 x ≥ 50 GB, 2.5" SATA-SSD, high endurance or • 1 x ≥ 80 GB, 2.5" SATA-SSD, standard or • 1 x ≥ 160 GB, 2.5" SATA-SSD, standard 5/36 2 GB optional or 4 GB optional or 8 GB optional or 16 GB optional Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation Box PC SIMATIC IPC427D ■ Ordering data SIMATIC IPC427D (Box PC) 1) 2) Processor and fieldbus: • Celeron U827E (1C/1T, 1.4 GHz, 1.5 MB cache); 2 x Gigabit Ethernet (IE/PN) • Celeron U827E (1C/1T, 1.4 GHz, 1.5 MB cache); 2 x Gigabit Ethernet (IE/PN); PROFIBUS DP12 • Celeron U827E (1C/1T, 1.4 GHz, 1.5 MB cache); 2 x Gigabit Ethernet (IE/PN); CAN interface • Core i3-3217UE (2C/4T, 1.6 GHz, 3 MB cache); 2 x Gigabit Ethernet (IE/PN) • Core i3-3217UE (2C/4T, 1.6 GHz,3 MB cache); 2 x Gigabit Ethernet (IE/PN); PROFIBUS DP12 • Core i3-3217UE (2C/4T, 1.6 GHz, 3 MB cache); 1 x Gigabit Ethernet (IE/PN); 1 x PROFINET (IRT, 3 ports) • Core i7-3517UE (2C/4T, 1.7 (2.8) GHz, 3 MB cache); 2 x Gigabit Ethernet (IE/PN) (optional ECC only here) • Core i7-3517UE (2C/4T, 1.7 (2.8) GHz, 3 MB cache); 2 x Gigabit Ethernet (IE/PN); PROFIBUS DP12 • Core i7-3517UE (2C/4T, 1.7 (2.8) GHz, 3 MB cache); 1 x Gigabit Ethernet (IE/PN); 1 x PROFINET (IRT, 3 ports) Mounting accessories: • DIN rail mounting • Wall mounting • Portrait mounting Work memory/NVRAM/ECC: • 1 GB • 2 GB • 4 GB • 8 GB • 4 GB with ECC (only with Core i7, 2 x Gigabit Ethernet (IE/PN)) • 8 GB with ECC (only with Core i7, 2 x Gigabit Ethernet (IE/PN)) • 1 GB and NVRAM • 2 GB and NVRAM • 4 GB and NVRAM • 8 GB and NVRAM • 4 GB with ECC and NVRAM (only with Core i7, 2 x Gigabit Ethernet (IE/PN)) • 8 GB with ECC and NVRAM (only with Core i7, 2 x Gigabit Ethernet (IE/PN)) Expansions/interface: • One RS 232, without PCIe • One RS 232 and one PCIe • One RS 232 and two PCIe • Second RS 232, without PCIe • Second RS 232 and one PCIe • Second RS 232 and second PCIe Operating system: • Without operating system • Windows Embedded Standard 7 SP1, English, 32-bit • Windows 7 Ultimate SP1, 32-bit, MUI (Eng, Ger, Fr, It, Sp) • Windows 7 Ultimate SP1, 64-bit, MUI (Eng, Ger, Fr, It, Sp) Order No. Order No. 6AG4140- 7 7 7 7 7 - 7 7 7 7 SIMATIC IPC427D (Box PC) 1) 2) (continued) 6AG4140- 7 7 7 7 7 - 7 7 7 7 Mass storage, externally accessible: • Without external mass storage • CFast 2 GB Without operating system • CFast 4 GB (only optionally with operating system if no internal mass storage) • CFast 8 GB (only optionally with operating system if no internal mass storage) • CFast 16 GB (only optionally with operating system if no internal mass storage) 0 1 2 3 Internal mass storage: • Without internal mass storage • CFast 2 GB, without software • CFast 4 GB, without software • CFast 8 GB, without software • CFast 16 GB, without software • SSD 50 GB high endurance (SLC) • SSD 80 GB Standard • HDD 250 GB • SSD 160 GB Standard 4 5 6 SIMATIC software preinstalled (bundles, only with Windows Embedded Standard 7): • Without SIMATIC software • WinAC RTX 2010 3) • WinCC RT Advanced, 128 PT • WinCC RT Advanced, 512 PT • WinCC RT Advanced, 2048 PT • WinCC RT Advanced, 4096 PT • WinCC RT Advanced 128 PT, WinAC RTX 2010 3) • WinCC RT Advanced 512 PT, WinAC RTX 2010 3) • WinCC RT Advanced 2048 PT, WinAC RTX 2010 3) • WinCC RT Advanced 4096 PT, WinAC RTX 2010 3) • WinAC RTX F 2010 3) • WinCC RT Advanced 128 PT, WinAC RTX F 2010 3) • WinCC RT Advanced 512 PT, WinAC RTX F 2010 3) • WinCC RT Advanced 2048 PT, WinAC RTX F 2010 3) • WinCC RT Advanced 4096 PT, WinAC RTX F 2010 3) 7 8 B D E A B C D G H J K L M N Power supply: • 24 V DC industrial power supply • 24 V DC and TPM (not for China and Russia) P 0 1 2 3 4 5 0 1 2 3 4 A B C D E G H K P A B C D E F J 5 K L M N P Q R S 0 8 1) "Built to order" – versions with a delivery time of max. 15 working days and with identified repair, if not preferred type. 2) For an up-to-date overview, see the SIMATIC PC online configurator at: www.siemens.com/ipc-configurator 3) Only with "main memory and NVRAM". Note: 0 4 Bundles with SIMATIC software only with Windows Embedded Standard 7, main memory and NVRAM (with RTX and RTX F), and CFast mass storage of 4 GB or more / SSD. 6 7 Siemens ST 80 / ST PC · 2013 5/37 © Siemens AG 2013 PC-based Automation Box PC SIMATIC IPC427D ■ Dimensional drawings 1.5 133 6.7 1.5 16.5 184 262 85 100 50 16.5 2 262 50 10 50.5 All dimensions in mm. For mounting cut-out see technical specifications. SIMATIC IPC427D, wall mounting 315 300 272 21.5 6.1 SIMATIC IPC427D, DIN rail mounting 5 25 15.3 143 55.5 61.5 G SIMATIC IPC427D, portrait mounting 5/38 Siemens ST 80 / ST PC · 2013 G_ST80_XX_00555 8.9 2.5 5.8 G_ST80_XX_00554 286 297 G 50.5 G 9 G_ST80_XX_00553 6.7 133 83.7 Ø 4.5 © Siemens AG 2013 PC-based Automation Box PC SIMATIC IPC427C ■ Overview ■ Technical specifications SIMATIC IPC427C General features Design DIN rail or wall mounting, front upright mounting, mounting position preferably horizontal, vertical possible Processor • Intel Core2 Duo 1.2 GHz, 800 MHz FSB, 3 MB SLC • Intel Core2 Solo 1.2 GHz, 800 MHz FSB, 3 MB SLC • Intel Celeron M 1.2 GHz, 800 MHz FSB, 1 MB SLC Chipset Intel GM45 / ICH9M Main memory 1 GB, (2/4 GB) DDR3 SDRAM Buffered SRAM 2 MB, of which 128 KB can be written within the buffer time Free slots for expansions Up to 3 x PCI-104, 3 W per slot Graphics • Integrated Intel GMAX4500 graphics • 8 ... 512 MB shared graphics memory (managed dynamically) • CRT resolution: 640 x 480 pixels up to max. 1920 x 1200 pixels at 32 bit colors • DVI-D resolution: 640 x 480 pixels up to max. 1920 x 1200 pixels at 32 bit colors Operating system • Without • Windows XP Embedded Standard 2009 preinstalled, in combination with CF card of 2 GB or more, solid-state drive, or hard drive • Windows XP Professional MUI (in combination with solid-state drive or hard drive; MUI: Multi Language User Interface) • Windows 7 Ultimate MUI (in combination with solid-state drive or hard drive; MUI: Multi Language User Interface) • Windows Embedded Standard 7 preinstalled, in combination with CF card of 4 GB or more, or solid-sate drive, or hard drive RMOS3 (can be ordered separately) • Linux1) (project-specific, on request) • Others on request project-specifically SIMATIC IPC427C (Microbox PC): The powerful embedded IPC – maintenance-free with versatile configuration • Ultra-compact • Maintenance-free • Intel Core2 Duo technology Power supply 1) • 24 V DC (19.2 V ... 28.8 V) • Isolated • With buffering of temporary power failures: Max. 10 ms at 0.85% rated voltage • Line side switch • With power failure indication by means of Power Fail signal Suitable for specific LINUX versions in accordance with the specifications of the Siemens manufacturer's declaration "Suitable for LINUX", see http://www.siemens.com/simatic-pc/suited-for-linux (LINUX is a trademark of Linus Torvald). Siemens ST 80 / ST PC · 2013 5/39 5 © Siemens AG 2013 PC-based Automation Box PC SIMATIC IPC427C ■ Technical specifications (continued) SIMATIC IPC427C Drives Flash drive Optional; replaceable, accessible, diagnosable • 2 GB • 4 GB • 8 GB • 16 GB Optional; internal, not accessible, diagnosable • 2 GB • 4 GB • 8 GB • 16 GB Solid-State Drive (SSD) Optional • 50 GB SATA, 2.5" in single-level cell (SLC) architecture (High Endurance), especially suitable for industrial applications • 80 GB SATA, 2.5" Standard Hard disk Optional • > 250 GB SATA CD-ROM Via USB (not included in scope of delivery) DVD-RW Via USB (not included in scope of delivery) Diskette Via USB (not included in scope of delivery) Temperature • Processor temperature • Motherboard • Messages can be evaluated by the application program Watchdog • Monitoring of program execution • Monitoring time can be parameterized in software • Can be parameterized for a fault or restart • Messages can be evaluated by the application program. Monitoring functions via the network • DiagBase • SIMATIC IPC DiagMonitor Remote monitoring capability for: • Watchdog • Temperature • Mass memory monitoring (SMART) • System/Ethernet monitoring (Heart Beat) • Runtime meter Communication: • Ethernet interface (SNMP protocol) • OPC for integration in SIMATIC software • Configuration of client/server architectures • Layout of log files Ambient conditions Interfaces PROFINET 3 x RJ45 (CP 1616-compatible, optional) PROFIBUS/MPI 12 Mbit/s (isolated, compatible to CP 5611) optional Ethernet • 2 x 10/100/1000 Mbit/s (RJ 45) • Two independent Intel 82574L controllers (via PCI-Express) • One controller with none-shared interrupt • With teaming function USB V2.0/High Speed: 4 x Serial COM1 (V.24) COM2 (V.24) optional (in expansion frame) DVI-I 1 x DVI-I (includes DVI-D and VGA) Keyboard Via USB (not included in scope of delivery) Mouse Via USB (not included in scope of delivery) 5 SIMATIC IPC427C Monitoring functions Degree of protection to EN 60529 (front/rear) IP20 Vibration load during operation Devices without hard disk: • Requirements according to: IEC 61131-2 • Tested according to: IEC 60068-2-6, Test Fc • Devices without drive: - 5-9 Hz, 3.5 mm deviation, 10x /axis, 1 octave/min - 9-150 Hz, 9.8 m/s2, 10x /axis, 1 octave/min Devices with hard disk: Wall mounting • Requirements according to: IEC 61131-2 • Tested according to: IEC 60068-2-6, Test Fc • 10 ... 58 Hz, 0.0375 mm deviation, 10x /axis, 1 octave/min • 58 ... 200 Hz, 4.9 m/s2, 10x /axis, 1 octave/min Shock loading during operation Devices without hard disk: • Requirements according to: IEC 61131-2 • Tested according to: IEC 60068-2-27, Test Ea • Module/rack: 150 m/s2, power-up, 11 ms shock duration Devices with hard disk: Wall mounting • Requirements according to: IEC 61131-2 • Tested according to: IEC 60068-2-27, Test Ea • Devices with drive: 50 m/s2, power-up, 30 ms shock duration 5/40 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation Box PC SIMATIC IPC427C ■ Technical specifications (continued) SIMATIC IPC427C Electromagnetic compatibility (EMC) • Emitted interference • Interference immunity, burst • Interference immunity, surge • ESD interference immunity • Immunity to high radio frequency interference • Immunity to high-frequency current feed • Immunity to magnetic fields EN 55022 Class B EN 61000-6-2 or IEC 61131-2: • 2 kV - Tested acc. to IEC 61000-4-4 • 1 kV symmetrical / 2 kV asymmetrical - Tested acc. to IEC 61000-4-5 1 kV to IEC 61000-4-5; symmetrical 2 kV to IEC 61000-4-5; asymmetrical According to NAMUR Recommendation NE 21 and EN 61000-6-2: • 6 kV contact discharge Tested acc. to IEC 61000-4-2 • 8 kV air discharge Tested acc. to IEC 61000-4-2 According to EN 61000-6-2 or IEC 61131-2: • Interference immunity 80 ... 1000 MHz: 10 V/m with 80% AM (1 kHz); tested acc. to IEC 61000-4-3; • 1.4 GHz ... 2 Hz: 10 V/m with 50% pulse modulation; tested according to IEC 61000-4-3 Acc. to NAMUR Recommendation NE 21 and EN 61000-6-2 or IEC 61131-2: • 10 kHz ... 80 MHz: 10 V with 80% AM (1 kHz) tested acc. to IEC 61000-4-6 Acc. to NAMUR Recommendation NE 21 and EN 61000-6-2 or IEC 61131-2: SIMATIC IPC427C System-tested SIMATIC Industrial Software WinAC RTX (F), WinCC flexible, WinCC (SCADA as of V7.0), WinCC RT Advanced and Professional Approvals UL508, UL60950, cULus Marine approval • • • • • • Only for configurations with CompactFlash or SSD memory Safety regulations • IEC 61131-2 • IEC 61010-1 • EN 60950-1 CE mark • EC Directive 89/336/EEC (EMC Directive) • Use in industry: • Applications in residential areas, business and trade environments as well as in workshops: - Emitted interference: EN 61000-6-4 - Noise immunity: EN 61000-6-2 • Applications in residential areas, business and trade environments as well as in workshops: - Emitted interference: EN 61000-6-3 - Noise immunity: EN 61000-6-1 Dimensions and weights Equipment dimensions (in mm) • • • • Weight, approx. 2 kg 50/60 Hz; 100 A/m rms value - tested acc. to IEC 61000-4-8 Ambient temperature during operation Moist heat • 0 ... 55 ºC with flash drive/SSD (horizontal; preferred mounting position; with derating) • 0 ... 50 ºC with flash drive/SSD (horizontal; preferred mounting position; maximum configuration) • 0 ... 50 ºC with flash drive/SSD (vertical) • 5 ... 40 ºC with hard disk (horizontal and vertical) GL - Germanische Lloyd BV - Bureau Veritas LR - Lloyds Register of Shipping ABS - American Bureau of Shipping DNV - Det Norske Veritas NKK - Nippon Kaiji Kyokai Width x height: 262 x 134 Depth of basic unit: 47 Depth of basic unit above rail: 50 Additional depth per expansion (1-3): 17 each 5 • With CompactFlash card/SSD: 95 % • With hard drive 80% Siemens ST 80 / ST PC · 2013 5/41 © Siemens AG 2013 PC-based Automation Box PC SIMATIC IPC427C ■ Ordering data SIMATIC IPC427C 1) Order No. Order No. 6ES7647- 7 B 7 7 7 - 7 7 7 0 Memory expansion • 1 GB DDR3 1066 SDRAM, SODIMM • 2 GB DDR3 1066 SDRAM, SODIMM • 4 GB DDR3 1066 SDRAM, SODIMM Intel Celeron M 1.2 GHz, 800 MHz FSB, SLC 0 KB; 512 MB DDR3 RAM; without HD; without flash drive; without operating system; 24 V DC industrial power supply Processor: • Intel Celeron M 1.2 GHz, 800 MHz FSB • Intel Celeron M 1.2 GHz, 800 MHz FSB, PROFIBUS • Intel Celeron M 1.2 GHz, 800 MHz FSB, CAN • Core2 Solo 1.2 GHz, 800 MHz FSB SLC, 3 MB • Core2 Solo 1.2 GHz, 800 MHz FSB SLC, 3 MB, PROFIBUS • Core2 Solo 1.2 GHz, 800 MHz FSB SLC, 3 MB, PROFINET • Core2 Duo 1.2 GHz, 800 MHz FSB SLC, 3 MB • Core2 Duo 1.2 GHz, 800 MHz FSB SLC, 3 MB, PROFIBUS • Core2 Duo 1.2 GHz, 800 MHz FSB SLC, 3 MB, PROFINET A B D E F G J K L Memory configuration: • 1 GB DDR3 1066, SODIMM • 2 GB DDR3 1066, SODIMM • 4 GB DDR3 1066, SODIMM Expansion (HW): • No expansion (HW) • Second RS232 interface in expansion rack 5 Drives exchangeable (accessible) • Without drive • 2 GB CompactFlash • 4 GB CompactFlash • 8 GB CompactFlash • 16 GB CompactFlash 2 3 4 6ES7648-2AH40-0KA0 6ES7648-2AH50-0KA0 6ES7648-2AH60-0KA0 Expansion kit PC/104 For integration of PC/104 modules in the SIMATIC Microbox PC; packing unit contains 6 expansion frames 6AG4070-0BA00-0XA0 SIMATIC PC adapter cable DVI-I acc. to VGA, 250 mm 6ES7648-3AB00-0XA0 SIMATIC PC DVI-I Y graphics adapter cable DVI-I to VGA and DVI-D 6ES7648-3AE00-0XA0 Portrait assembly kit Interfaces to the front 6ES7648-1AA20-0YB0 Expansion components From page 5/153 Communication products From page 5/186 For power supplies and uninterruptible power supplies From page 5/170 RMOS3 real-time operating system From page 5/146 0 1 0 2 3 4 5 Drives internal (not accessible) • Without internal drive • 250 GB HDD SATA • 50 GB SSD High Endurance SATA • 80 GB Standard SATA • 2 GB CompactFlash internal • 4 GB CompactFlash internal • 8 GB CompactFlash internal • 16 GB CompactFlash internal Operating system (preinstalled and activated)2) • Without operating system • Windows Embedded Standard 2009 English preinstalled on internal drive • Windows XP Professional MUI, SP3 (Eng, Ger, Fr, It, Sp) preinstalled on internal drive • Windows Embedded Standard 7 preinstalled on internal drive • Windows 7 Ultimate, 32-bit, MUI (Eng, Ger, Fr, It, Sp) preinstalled on internal drive Accessories X A D E N P Q R 0 0 X A 0 B 0 C 0 D 1) For an up-to-date overview, see the SIMATIC PC online configurator at: www.siemens.com/ipc-configurator Note: 2) XP Embedded on 2 GB CompactFlash or hard disk. XP Professional or Windows 7 only with hard disk/SSD. Ready-to-use SIMATIC IPC427C as bundles can be found under "Embedded Bundles". Software packages with SIMATIC WinCC flexible, SIMATIC WinCC RT Advanced, SIMATIC WinCC, SIMATIC WinCC RT Professional and SIMATIC WinAC RTX (F) can be ordered together with the SIMATIC IPC with a price advantage. 5/42 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation Box PC SIMATIC IPC427C ■ Dimensional drawings SIMATIC IPC427Cb 262 138 G_ST80_XX_00456 46.5 *B67B;;B 138 133 262 52.5 97.5 All dimensions in mm. For mounting cut-out see technical specifications. SIMATIC IPC427C, interfaces ■ More information Further information can be found in the Internet under: http://www.siemens.com/simatic-pc 5 Siemens ST 80 / ST PC · 2013 5/43 © Siemens AG 2013 PC-based Automation Box PC SIMATIC IPC627C ■ Overview ■ Technical specifications SIMATIC IPC627C Supply voltage Supply voltage Processor Processor Interfaces PROFIBUS/MPI SIMATIC IPC627C (Box PC): The high-end IPC – with maximum performance, functional scope and expansion capability It offers: • Maximum performance in the smallest space • Intel Core i7 technology Free slots 2 X PCI or 1xPCI & 1 x PCIe X16 (265 mm/185mm long) , 1xslot for CompactFlash Card Connection for keyboard/mouse USB / USB serial interface COM1: 1 x V.24 (RS232) Video interfaces • Graphics interface DVI-I: VGA / DVI combined Industrial Ethernet • Industrial Ethernet interface 2 x Fast Ethernet Monitoring functions Temperature Yes Watchdog Yes Status LEDs Yes Standards, approvals, certificates Approval CE, cULus (508), C-Tick Vibrations • Vibration load in operation Shock testing • Shock loading in operation Operating systems Operating system Software SIMATIC Software Siemens ST 80 / ST PC · 2013 Onboard, isolated, max. 12 Mbit/s, CP5611-compatible 4x USB 2.0 high speed/high current Ambient conditions Relative humidity • Relative humidity 5/44 Core i7-610E (2C/4T, 2.53 GHz, TB, HT, VT, AMT, 4MB cache); Core i3-330E (2C/4T, 2.13 GHz, HT, VT, 3MB cache); Celeron P4505 (2C/2T, 1.86 GHz, VT, 2MB cache); USB port EMC 5 100 - 240 V AC, optional 24 V CE, EN 55022A, EN 61000-6-4, EN 61000-6-2 Tested to DIN IEC 68-2-3, DIN IEC 68-2-30, DIN IEC 68-2-56: 5% to 80% at 25 °C (no condensation) Tested to DIN IEC 68-2-6: 10 to 58 Hz: 0.075 mm, 58 to 200 Hz: 9.8 m/s2 (1 g) Tested to DIN IEC 68-2-29: 50 m/s2 (5g), 30 ms, 100 shocks Windows XP Prof. SP3, MUI; Windows 7 Ultimate 32/64Bit, MUI; Windows Embedded Standard 2009 English on 8 GB CompactFlash; without operating system; Optionally in package with SIMATIC WinCC or WinCC flexible Dimensions Width 312 mm Height 80 mm; with DVD drive: 100 mm Depth 301 mm; incl. mounting rail © Siemens AG 2013 PC-based Automation Box PC SIMATIC IPC627C ■ Ordering data SIMATIC IPC627C 1) Order No. Order No. 6ES7647- 6 C 7 7 7 - 7 7 7 7 HD graphics on-board, 128 MB dyn. shared memory; 2 x 10/100/1000 Mbps Ethernet RJ45; 4 x USB V2.0 (high current); 1 x serial (COM1), RAID controller on-board; CompactFlash drive no. 1 at front (without CF); watchdog, temp./fan monitoring; Processor: • Celeron P4505 (2C/2T, 1.86 GHz, VT, 2 MB cache) • Celeron P4505 (2C/2T, 1.86 GHz, VT, 2 MB cache), PROFIBUS/MPI (CP5611-compatible), 2 MB battery-backed SRAM • Celeron P4505 (2C/2T, 1.86 GHz, VT, 2 MB cache), PROFINET (3 x RJ45, CP1616-compatible), 2 MB battery-backed SRAM • Core i3-330E (2C/4T, 2.13 GHz, HT, VT, 3 MB cache) • Core i3-330E (2C/4T, 2.13 GHz, HT, VT, 3 MB cache), PROFIBUS/MPI, 2 MB battery-backed SRAM • Core i3-330E (2C/4T, 2.13 GHz, HT, VT, 3 MB cache), PROFINET (3 x RJ45, CP1616-compatible), 2 MB battery-backed SRAM • Core i7-610E (2C/4T, 2.53 GHz, TB, HT, VT, AMT, 4 MB cache) • Core i7-610E (2C/4T, 2.53 GHz, TB, HT, VT, AMT, 4 MB cache), PROFIBUS/MPI, 2 MB battery-backed SRAM • Core i7-610E (2C/4T, 2.53 GHz, TB, HT, VT, AMT, 4 MB cache), PROFINET (3 x RJ45, CP1616compatible), 2 MB battery-backed SRAM Memory configuration • 1 GB DDR3 1066 DIMM • 2 GB DDR3 1066 DIMM • 3 GB DDR3 1066 DIMM • 4 GB DDR3 1066 DIMM • 8 GB DDR3 1066 DIMM • 2 GB DDR3 1066 DIMM, ECC • 4 GB DDR3 1066 DIMM, ECC • 8 GB DDR3 1066 DIMM, ECC Country-specific version/ power supply • 100/240 V AC industrial power supply with Namur; European cable • 100/240 V AC industrial power supply with Namur; UK cable • 100/240 V AC industrial power supply with Namur; Swiss cable • 100/240 V AC industrial power supply with Namur; USA cable • 100/240 V AC industrial power supply with Namur; Italian cable • 100/240 V AC industrial power supply with Namur; Chinese cable • 24 V DC industrial power supply Device Certification UL Class I Div. 2; 24 V DC industrial power supply • Device Certification UL Class I Div. 2; 110 / 230 V AC Industrial Power Supply with Namur SIMATIC IPC627C 1) (continued) 6ES7647- 6 C 7 7 7 - 7 7 7 7 PC slots • 2 x PCI free • 1 x PCI, 1x PCIe (x16) free 0 1 Drives • 250 GB HDD SATA • 250 GB HDD SATA; DVD+/-RW • 500 GB HDD SATA • 500 GB HDD SATA; DVD+/-RW • 2 x 250 GB SATA (2.5") • 2 x 250 GB SATA (2.5") + DVD+/-RW • RAID1 2 x 250 GB SATA (2.5") • RAID1 2 x 250 GB SATA (2.5"); DVD+/-RW • 50 GB SATA solid-state drive (SLC) • 50 GB SATA solid-state drive (SLC); DVD+/-RW • CompactFlash drive No. 2 installed, DVD+/-RW • CompactFlash drive No. 2 installed • DVD+/-RW • Without drives A B C D E Operating system (preinstalled and activated) • Windows XP Professional MUI, SP3 (Eng, Ger, Fr, It, Sp) • Windows 7 Ultimate, MUI (Eng, Ger, Fr, It, Sp), 32-bit, SP1 included • Windows 7 Ultimate, MUI (Eng, Ger, Fr, It, Sp), 64-bit, SP1 included • Windows Embedded Standard 2009 English on 8 GB CompactFlash • Without operating system F G H J Expansion • No expansion (software) • SIMATIC IPC DiagMonitor software included • SIMATIC IPC Image&Partition Creator software included • SIMATIC IPC DiagMonitor, Image & Partition Creator software included 0 1 2 3 4 5 6 7 A B C D E F G H J K U V W X A B C F X 0 1 2 3 0 1 2 3 4 5 6 7 8 1) For an up-to-date overview, see the SIMATIC PC online configurator at: www.siemens.com/ipc-configurator Siemens ST 80 / ST PC · 2013 5/45 5 © Siemens AG 2013 PC-based Automation Box PC SIMATIC IPC627C Order No. SIMATIC PC, 230 V AC power cable angled, 3 m for Box PC and Panel PC for • Austria, Belgium, Finland, France, Germany, Netherlands, Spain, Sweden • United Kingdom • Switzerland • USA • Italy • China 5 295.2 3.9 78.5 11.2 6ES7648-1AA10-0YA0 6ES7648-1AA10-0YB0 G_ST80_XX_00457 Portrait assembly kit • Interfaces upward/downward • Interfaces to the front 6ES7648-3AB00-0XA0 6ES7648-3AE00-0XA0 3.6 265 Graphics adapter cable • DVI-I acc. to VGA, 250 mm long • DVI-I acc. to VGA and DVI-D, 250 mm long (Y cable) 6ES7648-2CA01-0AA0 6ES7900-1AA00-0XA0 6ES7900-1BA00-0XA0 6ES7900-1CA00-0XA0 6ES7900-1DA00-0XA0 6ES7900-1EA00-0XA0 6ES7900-1FA00-0XA0 ■ More information Expansion components From page 5/153 Further information can be found in the Internet under: Communication products From page 5/186 http://www.siemens.com/simatic-pc For power supplies and uninterruptible power supplies From page 5/170 RMOS3 real-time operating system From page 5/146 Note: Software Packages with SIMATIC WinCC flexible, WinCC RT Advanced, SIMATIC WinCC, and SIMATIC WinAC RTX (F) can be ordered together with the SIMATIC IPC at favorable prices. More information under "Embedded Bundles / Packages for industrial PCs". 5/46 Siemens ST 80 / ST PC · 2013 272.8 PCI expansion card with COM1 and LPT 6ES7648-2AJ40-0KA0 6ES7648-2AJ40-1KA0 6ES7648-2AJ50-0KA0 6ES7648-2AJ50-1KA0 6ES7648-2AJ60-0KA0 6ES7648-2AJ60-1KA0 99.8 All dimensions in mm. For mounting cut-out see technical specifications. Accessories Memory expansions • 1 GB DDR3 1066, DIMM • 1 GB DDR3 1066, DIMM; ECC • 2 GB DDR3 1066, DIMM • 2 GB DDR3 1066, DIMM; ECC • 4 GB DDR3 1066, DIMM • 4 GB DDR3 1066, DIMM; ECC ■ Dimensional drawings 99.1 ■ Ordering data © Siemens AG 2013 PC-based Automation Box PC SIMATIC IPC827C ■ Overview ■ Technical specifications SIMATIC IPC827C Supply voltage Supply voltage 100 - 240 V AC, optional 24 V Processor Processor Core i7-610E (2C/4T, 2.53 GHz, TB, HT, VT, AMT, 4MB cache); Core i3-330E (2C/4T, 2.13 GHz, HT, VT, 3MB cache); Celeron P4505 (2C/2T, 1.86 GHz, VT, 2MB cache); Interfaces PROFIBUS/MPI SIMATIC IPC827C (Box PC): The high-end IPC – with maximum performance, functional scope and expansion capability It offers: • Maximum performance and high expandability • with Intel Core i technology Onboard, isolated, max. 12 Mbit/s, CP5611-compatible USB port 4x USB 2.0 high speed/high current Free slots 3xPCI, 1 x PCIe (x4), 1 x PCIe (x16), 1xslot for CompactFlash Card Connection for keyboard/mouse USB / USB serial interface COM1: 1 x V.24 (RS232) Video interfaces • Graphics interface DVI-I: VGA / DVI combined Industrial Ethernet • Industrial Ethernet interface 2 x Fast Ethernet Monitoring functions Temperature Yes Watchdog Yes Status LEDs Yes Standards, approvals, certificates Approval CE, cULus (508), C-Tick EMC Ambient conditions Relative humidity • Relative humidity Vibrations • Vibration load in operation Shock testing • Shock loading in operation Operating systems Operating system Software SIMATIC Software CE, EN 55022A, EN 61000-6-4, EN 61000-6-2 Tested to DIN IEC 68-2-3, DIN IEC 68-2-30, DIN IEC 68-2-56: 5% to 80% at 25 °C (no condensation) Tested to DIN IEC 68-2-6: 10 to 58 Hz: 0.075 mm, 58 to 200 Hz: 9.8 m/s2 (1 g) Tested to DIN IEC 68-2-29: 50 m/s2 (5g), 30 ms, 100 shocks Windows XP Prof. SP3, MUI; Windows 7 Ultimate 32/64Bit, MUI; Windows Embedded Standard 2009 English on 8 GB CompactFlash; without operating system; Optionally in package with SIMATIC WinCC or WinCC flexible Dimensions Width 312 mm Height 150 mm; with DVD drive: 170 mm Depth 301 mm; incl. mounting rail Siemens ST 80 / ST PC · 2013 5/47 5 © Siemens AG 2013 PC-based Automation Box PC SIMATIC IPC827C ■ Ordering data SIMATIC IPC827C Order No. Processor • Celeron P 4505 (2C/2T, 1.86 GHz, VT, 2 MB cache) • Celeron P 4505 (2C/2T, 1.86 GHz, VT, 2 MB cache); PROFIBUS/MPI; 2 MB battery-backed SRAM • Celeron P 4505 (2C/2T, 1.86 GHz, VT, 2 MB cache); PROFINET (3 x RJ45, CP1616-compatible); 2 MB battery-backed SRAM • Core i3-330E (2C/4T, 2.13 GHz, HT, VT, 3 MB cache) • Core i3-330E (2.13 GHz, HT, VT, 3 MB cache); PROFIBUS/MPI; 2 MB battery-backed SRAM • Core i3-330 (2C/4T, 2.13 GHz, HT, VT, 3 MB cache); PROFINET (3 x RJ45, CP1616-compatible); 2 MB battery-backed SRAM • Core i7-610E (2C/4T, 2.53 GHz, TB, HT, VT, AMT, 4 MB cache) • Core i7-610E (2C/4T, 2.53 GHz, TB, HT, VT, AMT, 4 MB cache); PROFIBUS/MPI; 2 MB battery-backed SRAM • Core i7-610E (2C/4T, 2.53 GHz, TB, HT, VT, AMT, 4 MB cache); PROFINET (3 x RJ45, CP1616-compatible); 2 MB battery-backed SRAM 5 Memory configuration • 1 GB DDR3 1066 DIMM • 2 GB DDR3 1066 DIMM • 3 GB DDR3 1066 DIMM • 4 GB DDR3 1066 DIMM • 8 GB DDR3 1066 DIMM • 2 GB DDR3 1066 DIMM, ECC • 4 GB DDR3 1066 DIMM, ECC • 8 GB DDR3 1066 DIMM, ECC Power supply • 100/240 V AC industrial power supply with Namur; European cable • 100/240 V AC industrial power supply with Namur; UK cable • 100/240 V AC industrial power supply with Namur; Swiss cable • 100/240 V AC industrial power supply with Namur; USA cable • 100/240 V AC industrial power supply with Namur; Italian cable • 100/240 V AC industrial power supply with Namur; Chinese cable • 24 V DC industrial power supply 5/48 Order No. 6ES7647- 6 P 7 7 7 - 7 7 7 7 Siemens ST 80 / ST PC · 2013 SIMATIC IPC827C (continued) Expansions (HW) • 3 x PCI, 2 x PCIe (x4), 1 x PCIe (x16) available A B Mass storage • 250 GB HDD SATA • 250 GB HDD SATA; DVD+/-RW • 500 GB HDD SATA • 500 GB HDD SATA; DVD+/-RW • 2 x 250 GB SATA (2.5") • 2 x 250 GB SATA (2.5") + DVD+/-RW • RAID1 2 x 250 GB SATA (2.5") • RAID1 2 x 250 GB SATA (2.5"); DVD+/-RW • Solid-state drive 50 GB (SLC) • Solid-state drive 50 GB (SLC); DVD+/-RW • DVD+/-RW • Without drives C D E F Operating system (preinstalled and activated) • Windows XP Professional MUI, SP3 (Eng, Ger, Fr, It, Sp) • Windows 7 Ultimate, 32-bit, MUI (Eng, Ger, Fr, It, Sp) • Windows 7 Ultimate, 64-bit, MUI (Eng, Ger, Fr, It, Sp) • Windows XP Embedded Standard 2009 English on 8 GB CompactFlash • Without operating system G H J Expansion software • No expansion (software) • SIMATIC IPC DiagMonitor software included • SIMATIC IPC Image&Partition Creator included • SIMATIC IPC DiagMonitor & Image & Partition Creator included 0 1 2 3 4 5 6 7 6ES7647- 6 P 7 7 7 - 7 7 7 7 0 A B C D E F G H J K W X A B C F X 0 1 4 5 Note: Windows Embedded only without RAID option 0 1 2 3 4 5 6 Note: Software Packages with SIMATIC WinCC flexible, WinCC RT Advanced, SIMATIC WinCC, and SIMATIC WinAC RTX (F) can be ordered together with the SIMATIC IPC at favorable prices. More information under "Embedded Bundles / Packages for industrial PCs". © Siemens AG 2013 PC-based Automation Box PC SIMATIC IPC827C Order No. All dimensions in mm. For mounting cut-out see technical specifications. Accessories Portrait assembly kit • Interfaces upward/downward • Interfaces to the front Power supply cable SIMATIC PC, power cable for 230 V AC, angled, 3 m for Box PC and Panel PC for • Austria, Belgium, Finland, France, Germany, Netherlands, Spain, Sweden • United Kingdom • Switzerland • USA • Italy • China 173.2 3 6ES7648-3AB00-0XA0 6ES7648-3AE00-0XA0 295.2 11 6ES7648-1AA30-0YA0 6ES7648-1AA30-0YB0 6ES7900-1AA00-0XA0 6ES7900-1BA00-0XA0 6ES7900-1CA00-0XA0 6ES7900-1DA00-0XA0 6ES7900-1EA00-0XA0 6ES7900-1FA00-0XA0 297.2 G_ST80_XX_00458 Graphics adapter cable • DVI-I acc. to VGA, 250 mm long • DVI-I acc. to VGA and DVI-D, 250 mm long (Y cable) 6ES7648-2CA01-0AA0 2.4 PCI expansion card with COM1 and LPT 6ES7648-2AJ40-0KA0 6ES7648-2AJ40-1KA0 6ES7648-2AJ50-0KA0 6ES7648-2AJ50-1KA0 6ES7648-2AJ60-0KA0 6ES7648-2AJ60-1KA0 269.8 Memory expansions • 1 GB DDR3 1066, DIMM • 1 GB DDR3 1066, DIMM; ECC • 2 GB DDR3 1066, DIMM • 2 GB DDR3 1066, DIMM; ECC • 4 GB DDR3 1066, DIMM • 4 GB DDR3 1066, DIMM; ECC ■ Dimensional drawings 265 ■ Ordering data ■ More information Expansion components From page 5/153 Weitere Informationen finden Sie im Internet unter: Communication products From page 5/186 http://www.siemens.com/simatic-pc For power supplies and uninterruptible power supplies From page 5/170 RMOS3 real-time operating system From page 5/146 5 Siemens ST 80 / ST PC · 2013 5/49 © Siemens AG 2013 PC-based Automation SIMATIC Panel PC Panel PC ■ Overview SIMATIC IPC277: The embedded Nanopanel PC – maintenance-free and compact with displays starting from 7" • High degree of flexibility for selecting rugged widescreen fronts from 7" to 19" for a more freely configurable display area • High resolution, large viewing angle, and up to 100% dimmable backlighting for a brilliant display with optimized power consumption • Absolutely maintenance-free due to the use of CompactFlash or SSD as mass storage and fanless operation up to 50 °C ambient temperature • Maximum industrial functionality due to non-volatile retentive memory (option) • Ready-to-use embedded bundles with visualization and/or control software SIMATIC Panel PCs are suitable thanks to their high industrial compatibility for use in control cabinets, consoles and control panels, as well as directly on the machine. Typical areas of application can be found in both factory and process automation. There is a broad range of robust, high-performance SIMATIC Panel PCs available for different requirements. 5 Shared industrial functionality • High-quality components and modules with a high MTBF (mean time between failure), which also ensure 24-hour operation in the extended temperature range. • High swing/shock capacity of the devices through special hard-disk suspensions, locked connectors and card retainers • Rugged housing model with high electromagnetic compatibility (EMC) and integrated industrial power supplies (also as per NAMUR) • Service-friendly device design • Bright, brilliant displays in different sizes up to 19" • Same front panel mounting dimensions and uniform front design across all device families • Rugged fronts protected from dust, humidity and chemical substances (front-side IP65 / NEMA 4 degrees of protection) SIMATIC IPC477D: The powerful embedded Panel PC – maintenance-free with versatile configuration • Compact design • High performance with highly compact design and ruggedness • Flexible expansion using a PCIe I/O card (optional) • No rotating parts (without fan and hard disk) • High security due to Windows Embedded Standard 7 operating system • Ready-to-use devices with optionally preinstalled software - HMI: Innovative HMI software WinCC RT Advanced (incl. archives and recipes) - RTX: with real-time capable software PLC WinAC RTX • Retentive memory on board (NV-RAM, usable with WinAC RTX) SIMATIC HMI IPC477C: The powerful embedded Panel PC – maintenance-free with versatile configuration • Compact design • High performance with highly compact design and ruggedness • Also available as PRO version (all-round IP65 degree of protection) with 15" and 19" Touch displays • No rotating parts (without fan and hard disk) • High security due to Microsoft Windows Embedded Standard 2009 or Windows Embedded Standard 7 operating systems • Ready-to-use devices with optionally preinstalled software - HMI: Innovative HMI software WinCC flexible (incl. archives and recipes) - RTX: with real-time capable software PLC WinAC RTX • Retentive memory on board (NV-RAM, usable with WinAC RTX) SIMATIC HMI IPC677: The high-end Panel PC – with maximum performance, functional scope and expansion capability • Rugged, expandable industrial PC with different front panels • Rugged design for industrial use • Complete PC openness • Optional PROFIBUS or PROFINET onboard • All CPUs with dual core 5/50 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation SIMATIC Panel PC Panel PC ■ Overview (continued) SIMATIC IPC277D SIMATIC IPC477D SIMATIC HMI IPC477C SIMATIC HMI IPC577C SIMATIC HMI IPC677C 7) Centralized configuration • • • • • Distributed configuration (via remote kit) - - - - - Size 7"/9"/12"/15"/19“ Widescreen TFT 12"/15"/19"/22" Widescreen TFT 12"/15"/19" TFT 12"/15"/19" TFT 12"/15"/19" TFT Resolution 800 x 480 / 800 x 480 / 1280 x 800 / 1280 x 800 / 1366 x 768 1280 x 800 / 1280 x 800 / 1366 x 768/ 800 x 600/ 1024 x 768/ 1280 x 1024 800 x 600/ 1024 x 768/ 1280 x 1024 800 x 600/ 1024 x 768/ 1280 x 1024 Membrane keyboard - • 8) • 1) • 1) • 1) Touch screen • • • • • Power supply 24 V DC / 110/240 V AC •/- •/- •/- •/• •/• Processor • Intel Atom E640, 1.0 GHz; • Intel Atom E660, 1.3 GHz • Intel Core i73517UE, 1.7 GHz, 4 MB SLC • Intel Core i33217UE, 1.6 GHz, 3 MB SLC • Intel Celeron 827E 1.4 GHz, 1.5 MB SLC • Intel Celeron M 1.2 GHz • Intel Core2 Solo 1.2 GHz • Intel Core2 Duo 1.2 GHz • Intel Celeron M 1.2 GHz • Intel Core2 Solo 1.2 GHz • Intel Core2 Duo 1.86 GHz • Intel Celeron P4505, 1.86 GHz, 2 cores, 2 MB cache • Intel Core i3-330E, 2.13 GHz, 2 cores, 4 threads, 3 MB cache, HT, VT-x • Intel Core i7-620E, 2.53 GHz, 2 cores, 4 threads, 4 MB cache, TB, HT, VT-x, VT-d Main memory 1 GB, 2 GB 1 GB, 2 GB, 4 GB, 8 GB 1 GB, 2 GB, 4 GB 1 GB, 2 GB, 4 GB 1 GB, expandable up to 8 GB, optional ECC Expansion slots 1 x CF slot for CompactFlash card (externally accessible) • 1 x PCIe; • 2 x CFast slot (externally accessible) 2 x CF slot for CompactFlash Card (internally and externally accessible) • 1 x PCI 2) • 1 x CF slot for CompactFlash card (externally accessible) • 2 x PCI or 1 x PCI and 1 x PCIe x16 • 1 x CF slot for CompactFlash card (externally accessible) Operating system • Windows Embedded Standard 2009 or XP Professional MUI • Windows Embedded Standard 7 (32-bit) or Windows 7 Ultimate MUI (32-bit) • Without • Windows 7 Ultimate MUI (32-bit or 64-bit) • Windows Embedded Standard 7 (32-bit) • Windows Embedded 2009 or XP Professional MUI • Windows 7 Ultimate MUI (32-bit) or Windows Embedded Standard 7 (32-bit) • Without • Windows Embedded 2009 or XP Professional MUI • Without • Windows XP Professional MUI • Windows 7 Ultimate 32-bit MUI • Windows 7 Ultimate 64-bit MUI • Windows Embedded Standard 2009 on CF Design Display 1920 x 1080 Operator controls General features Interfaces PROFIBUS/MPI - • • • • PROFINET (RT/IRT) •/- •/• •/• •/• •/• Ethernet 2x 10/100/1000 Mbps 2x 10/100/1000 Mbps 2x 10/100/1000 Mbps 2x 10/100/1000 Mbps 2x 10/100/1000 Mbps USB • • • • • Serial interface • • • • • Graphics interface - • • • • Siemens ST 80 / ST PC · 2013 5/51 5 © Siemens AG 2013 PC-based Automation SIMATIC Panel PC Panel PC ■ Overview (continued) SIMATIC IPC277D SIMATIC IPC477D SIMATIC HMI IPC477C SIMATIC HMI IPC577C SIMATIC HMI IPC677C 7) Vibration load during operation 1g 1g 1g 1 g 3) 1 g 3) Shock loading during operation 5g 5g 5g 5 g 3) 5g Permissible temperature during operation with maximum configuration +0 °C … +50 °C 7) +0 °C … +50 °C 7) +0 °C … +50 °C 7) +0 °C … +45 °C 7) +5 °C … +50 °C 6) 8) Ambient conditions Power loss in maximum configuration 7" display 27 W 9" display 29 W 12" display 34 W 55 W 40 W 4) 55 W 5) 140 W 5) 15" display 42 W 56 W 45 W 4) 57 W 5) 140 W 5) 19" display 45 W 65 W 60 W 4) 84 W 5) 163 W 5) 22" display 74 W • Available - Not available 5 1) 12"/15" displays 2) All slots with card retainer 3) Valid with CF or SSD; with HDD: 5 g / 0.5 g; 4) 3 W taken into account for each PCI/PCIe slot 5) 15 W taken into account for each PCI/PCIe slot 6) +0 °C to +50 °C; max. +50 °C in installation space; max. 40 °C if at the front 7) +0 °C to +45 °C for 19" 8) 15" display optionally as Touch/Key version 9) With 12" and 15", vertical installation and use of CFast or SSD ■ More information Additional information is available on the Internet at: http://www.siemens.com/simatic-panel-pc Note: Do you need a specific modification or extension to the products described here? Then refer to "Customized Automation". There you will find information about additional and generally available sector-specific products as well as options for customer-specific modification and adaptation. Examples are: • Specific front panels for SIMATIC Panel PC, e.g. honing oil-resistant or with lateral function/movement keys • SIMATIC HMI Net Panel with 46" large-scale display 5/52 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation SIMATIC Panel PC SIMATIC IPC277D ■ Overview ■ Technical specifications SIMATIC IPC277D General features SIMATIC IPC277D: The embedded Nanopanel PC – maintenance-free and compact with displays starting from 7" • Offers great flexibility in the selection of rugged widescreen fronts • From 7" to 19" for more freely configurable display area • High resolution, large viewing angle, and up to 100% dimmable backlighting for a brilliant display with optimized power consumption • Absolutely maintenance-free due to the use of CompactFlash and SSD as mass storage and fanless operation up to 50 °C ambient temperature • Maximum industrial functionality due to non-volatile retentive memory • Ready-to-use embedded bundles with visualization or/and control software The following front installation versions are available: • 7" Touch • 9" Touch • 12" Touch • 15" Touch with USB interface on the front • 19" Touch with USB interface on the front • All fronts as widescreen version Processors • Intel Atom E660 1.3 GHz, 2 GB RAM • Intel Atom E640 1.0 GHz, 1 GB RAM Chipset Intel Controller Hub EG20T NVRAM optional 512 KB, of which 128 KB can be written within the buffer time Operating system • Windows Embedded Standard 2009 preinstalled, in combination with CF card of 2 GB or more, or solid-state drive, or hard drive (optional) • Windows XP Professional MUI (in combination with solid-state drive or hard drive; MUI: Multi Language User Interface) (optional) • Windows Embedded Standard 7 32 bit, preinstalled, in combination with CF card or solid-state drive (optional) • Windows 7 Ultimate MUI 32 bit (in combination with solid-state drive; MUI: Multi Language User Interface) (optional) • Linux 1) (project-specific, on request) Others on request project-specifically Power supply • 24 V DC (20.4 V ... 28.8 V) • Isolated • With buffering of temporary power failures: max. 10 ms • Line side switch • With power failure indication by means of Power Fail signal Drives FlashDrive Optional; replaceable, accessible, diagnosable • 2 GB • 4 GB • 8 GB • 16 GB Solid-state drive (SSD) Optional • 50 GB SATA, High Endurance, 2.5" • 80 GB SATA, Standard, 2.5" CD/DVD/Floppy Via USB (not included in scope of delivery) Interfaces PROFINET PROFINET RT via Standard Ethernet controller Ethernet • 2 x 10/100/1000 Mbps (RJ 45) • Two independent Intel Controllers: Intel 82574L / Intel Controller Hub EG20T With teaming function USB V2.0, 3 x Serial COM1 (V.24) Keyboard Via USB (not included in scope of delivery) Mouse Via USB (not included in scope of delivery) 1) Suitable for specific LINUX versions in accordance with the specifications of the Siemens manufacturer's declaration "Suitable for LINUX", see http://www.siemens.com/simatic-pc/suited-for-linux (LINUX is a trademark of Linus Torvald). Siemens ST 80 / ST PC · 2013 5/53 5 © Siemens AG 2013 PC-based Automation SIMATIC Panel PC SIMATIC IPC277D ■ Technical specifications (continued) SIMATIC IPC277D SIMATIC IPC277D Monitoring functions Temperature Monitoring functions • Processor temperature • Motherboard Messages can be evaluated by the application program • Monitoring of program execution • Monitoring time can be parameterized in software • Can be parameterized for a fault or restart Watchdog Temperature Yes Watchdog Yes Mass storage Yes Ambient conditions Vibration load during operation Requirements according to: IEC 61131-2, tested according to: IEC 60068-2-6, Test Fc 10-58: 0.0375 mm, 58-200: 9.8 m/s2, 10x /axis • DiagBase • SIMATIC IPC DiagMonitor Shock loading during operation Remote monitoring capability for: • Watchdog • Temperature • Mass memory monitoring (SMART) • System/Ethernet monitoring (Heart Beat) • Runtime meter Requirements according to: IEC 61131-2, tested according to: IEC 60068-2-27, test Ea, 50 m/s2 Relative humidity Tested in accordance with DIN IEC 68-78, DIN IEC 60068-2-30: 5% to 80% at 25 °C (no condensation) Maximum permissible installation angle +/- 45° over vertical Ambient temperature during operation 0 °C … +50° C in maximum configuration; no fan (19": 0 °C … +45 °C) Messages can be evaluated by the application program Monitoring functions via the network Communication: • Ethernet interface (SNMP protocol) • OPC for integration in SIMATIC software • Configuration of client/server architectures • Structure of log files Supply voltage Supply voltage 5 Certifications & standards Approvals CE, cULus (508), marine approval available for 7" /9" /12", 15" /19" available soon: GL, LRS, BV, DNV, ABS, ClassNK EMC CE, FFC A, 55022A, EN 61000-6-4, EN 61000-6-2 24 V DC SIMATIC IPC277D Front panel 7" TFT Touch, widescreen 9" TFT Touch, widescreen 12" TFT Touch, widescreen 15" TFT Touch, widescreen 19" TFT Touch, widescreen 800 x 480 800 x 480 1280 x 800 1280 x 800 1366 x 768 Touch pen, touch protective films Touch pen, touch protective films Touch pen, touch protective films Touch pen, touch protective films Touch pen, touch protective films Display Resolution (W x H in pixels) General features Accessories Type of operation Function keys No No No No No Alphanumeric keyboard No No No No No Touch screen (analog/resistive) Yes Yes Yes Yes Yes USB port on the front No No No Yes Yes Centralized configuration Yes Yes Yes Yes Yes Distributed configuration No No No No No Mounting dimensions in centralized configuration (W x H x D) in mm 197 x 141 x 71 251 x 166 x 71 310 x 221 x 66 396 x 291 x 73 465 x 319 x 73 Operator control unit (W x H) in mm 214 x 158 274 x 190 330 x 241 415 x 310 483 x 337 Weight 1500 g 1950 g 2750 g 4000 g 5700 g Max. power loss in maximum configuration 27 W 29 W 37 W 42 W 45 W Design Dimensions 5/54 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation SIMATIC Panel PC SIMATIC IPC277D ■ Ordering data Nanopanel PC SIMATIC IPC277D Order No. Order No. 6AV7881- 7 A 7 0 0 - 7 7 7 0 Accessories Interfaces: 2 x Gbit LAN (RJ45), 1 x serial (COM1), 3 x USB Touch protective films 7" 1) 6AV2124-6GJ00-0AX0 Touch protective films 9" 1) 6AV2124-6JJ00-0AX0 Operating unit • Touch 7" TFT • Touch 9" TFT • Touch 12" TFT • Touch 15" TFT, front USB interface • Touch 19" TFT, front USB interface Touch protective films 12" 1) 6AV2124-6MJ00-0AX0 Touch protective films 15" 1) 6AV2124-6QJ00-0AX0 Touch protective films 19" 1) 6AV2124-6UJ00-0AX0 Bracket clamp, long for 15", 19" and 22" widescreen, Comfort Panels, IPC, Flat Panel monitors and Thin Client (except SCD1900 19" widescreen) 6AV6671-8XK00-0AX4 Touch pen Captive pen for operation of the touch devices, mounting of the support on the control cabinet or directly on the PRO unit 6AV7672-1JB00-0AA0 Processors / memory configuration / NVRAM • Atom E640 (1.0 GHz), 1 GB RAM • Atom E640 (1.0 GHz), 1 GB RAM, NVRAM • Atom E660 (1.3 GHz), 2 GB RAM • Atom E660 (1.3 GHz), 2 GB RAM, NVRAM Drives • Without drive, with CF slot • 2 GB SIMATIC PC CompactFlash • 4 GB SIMATIC PC CompactFlash • 8 GB SIMATIC PC CompactFlash • 16 GB SIMATIC PC CompactFlash • 50 GB Solid-State Drive SATA (High Endurance) • 80 GB Solid-State Drive SATA (Standard) Operating system • Without operating system • WES 2009 preinstalled (CF from 2 GB/SSD) • XP-Prof. MUI preinstalled on SSD • WES 7 32 bit preinstalled (CF from 4 GB/SSD) • Windows 7 MUI 32 bit preinstalled on SSD Software bundles • Without RTX/HMI software • RTX: WinAC RTX 2010 • RTX-F: WinAC RTX F 2010 • HMI: WinCC RT Advanced 128 PT • HMI: WinCC RT Advanced 512 PT • HMI: WinCC RT Advanced 2048 PT • HMI/RTX: RT 128 PT • HMI/RTX: RT 512 PT • HMI/RTX: RT 2048 PT • HMI/RTX-F: RT 128 PT • HMI/RTX-F: RT 512 PT • HMI/RTX-F: RT 2048 PT 1 2 3 4 5 A B E F 1) 0 1 2 3 4 7 10 units per packing unit Please be sure to note: The IPC277D with bundled software is always supplied with inserted CF card. The licenses are on the supplied USB flash drive. 8 A B C D E 5 A B C F G H M N P R S T Siemens ST 80 / ST PC · 2013 5/55 © Siemens AG 2013 PC-based Automation SIMATIC Panel PC SIMATIC IPC277D ■ Dimensional drawings 141.5 G_ST80_XX_00468 38 72.6 6.2 276 2.3 196 308 99.5 10.5 310 129.5 32.5 4.8 164 190 SIMATIC IPC277D 12" version 289 141.5 2.3 177.6 66.4 G_ST80_XX_00466 77.3 71.1 36.5 330 SIMATIC IPC277D 7" version 274 SIMATIC IPC277D 9" version 5/56 Siemens ST 80 / ST PC · 2013 SIMATIC IPC277D 15" version G_ST80_XX_00518 73 6.2 249 2,3 25.5 177.6 G_ST80_XX_00467 35.7 394 77.3 71.1 36.5 6.2 415 2.3 5 4.8 75.5 6.2 8.5 214 219 241 4.8 140 129.5 158 All dimensions in mm. For mounting cut-out see technical specifications. © Siemens AG 2013 PC-based Automation SIMATIC Panel PC SIMATIC IPC277D ■ Dimensional drawings (continued) ■ More information Further information can be found on the Internet at: 141.5 10.5 317 113,5 337 http://www.siemens.com/simatic-panel-pc 483 6.2 25.5 73 2,3 G_ST80_XX_00519 463 SIMATIC IPC277D 19" version 5 Siemens ST 80 / ST PC · 2013 5/57 © Siemens AG 2013 PC-based Automation SIMATIC Panel PC SIMATIC IPC477D ■ Overview ■ Technical specifications SIMATIC IPC477D General features SIMATIC IPC477D: The powerful embedded Panel PC – maintenance-free with versatile configuration • Embedded PC platform with extremely high industrial compatibility for demanding tasks in the field of PC-based automation • Maintenance-free (no rotating components such as fan and hard disk) • Rugged construction: The PC is resistant to even the harshest mechanical stress and is extremely reliable in operation • Compact design • Battery-independent retentive memory onboard • High degree of investment security • Fast integration capability 5 The following front versions are available: • Built-in versions - 12" TFT Touch - 15" TFT Touch - 15" TFT Touch/Key - 19" TFT Touch - 22" TFT Touch 5/58 Siemens ST 80 / ST PC · 2013 Supply voltage1) • 24 V DC (-20 % / +20 %) 1) • 100 - 240 V AC (-15 % / +20 %); 50 - 60 Hz Brief voltage interruption in accordance with NAMUR • Min. 20 ms (DC) • Min. 20 ms (AC); max. 10 events per hour; min. 1 s recovery time Power consumption (DC) of devices (without expansions): • 12" display • 15" display • 19" display • 22" display 55 W 56 W 65 W 74 W Additional power consumption of devices with expansions: • DVD drive • PCIe card 1W 5W Processor • Intel Celeron 827E 1.4 GHz; 1.5 MB SLC or • Intel Core i3-3217UE 1.6 GHz; 3 MB SLC or • Intel Core i7-3517UE 1.7 GHz; 4 MB SLC Main memory • SO-DIMM module; 1024 MB DDR3-SDRAM or • SO-DIMM module; 2048 MB DDR3-SDRAM or • SO-DIMM module; 4096 MB DDR3-SDRAM or • SO-DIMM module; 8192 MB DDR3-SDRAM Buffer memory 2) 512 KB MRAM Drive and storage media SATA drive 1 slot Solid-state drive • 1 x ≥ 50 GB; 2.5" SATA-SSD, high endurance or • 1 x ≥ 80 GB; 2.5" SATA-SSD, standard or • 1 x ≥ 160 GB; 2.5" SATA-SSD, standard Hard disk drive (HDD) • 1 x ≥ 250 GB, 2.5"-SATA-HD CFast card • • • • DVD drive, RW 1 slot for devices with expansion 2 GB or 4 GB or 8 GB or 16 GB 1) The generation of the supply voltage by the line-side power supply must be realized as safety extra-low voltage with safe electrical isolation, isolated according to IEC 60364 4 41, or as SELV according to IEC/UL/EN/DIN-EN 60950-1. 2) For devices with retentivity. © Siemens AG 2013 PC-based Automation SIMATIC Panel PC SIMATIC IPC477D ■ Technical specifications (continued) SIMATIC IPC477D Display, resolution SIMATIC IPC477D Ethernet 3) Graphics • 2 x RJ45 connection, Intel 82579LM and Intel 82574L 10/100/1000 Mbps, electrically isolated, teaming-capable 4) • 12" screen diagonal with LED backlighting, resolution 1280 × 800 pixels, WXGA (Wide XGA) • 15" screen diagonal with LED backlighting, resolution 1280 × 800 pixels, WXGA(Wide XGA) • 19" screen diagonal with LED backlighting, resolution 1366 x 768 pixels • 22" screen diagonal with LED backlighting, resolution 1920 x 1080 pixels Slot for PCIe expansion cards Degree of protection Resistive Tyco Elotouch controller ELO CTR-2216SU-AT-CHP-00, touch screen, analog resistive, touch force with test pen of 2 mm diameter: 5 N • IP 20 to IEC 60529 (enclosure) • IP 65 (front) Quality assurance In accordance with ISO 9001 Backlighting (MTBF) LED Emitted interference S EN 61000-6-4; CISPR 22 Class A; FCC Class A Half brightness life time, typical Min. 50000 h at 50 °C, 50% brightness Immunity with regard to conducted interference on the supply lines Graphics controller • Intel HD 2000 or • Intel HD 4000 Graphics memory • 32 … 512 MB shared memory • ± 2 kV to IEC 61000-4-4; burst • ± 1 kV to IEC 61000-4-5; surge symmetrical • ± 2 kV to IEC 61000-4-5; surge asymmetrical Resolutions, frequency, colors • DVI-I: 640 x 480 … 1920 x 1200, 60 Hz • DP display port: 1920 x 1200, 60 Hz Noise immunity on signal lines • ± 2 kV to IEC 61000-4-4; burst, length > 3 m • ± 1 kV to IEC 61000-4-4; burst, length < 3 m • ± 2 kV to IEC 61000-4-5; symmetrical surge, length > 30 m Immunity to static discharge • ± 6 kV, contact discharge at the front to IEC 61000-4-2 • ± 4 kV contact discharge at the rear to IEC 61000-4-2 • ± 8 kV air discharge to IEC 61000-4-2 Immunity to high radio frequency interference • 10 V/m, 80 … 1000 MHz 80 % AM to IEC 61000-4-3 • 1 V/m, 2 … 2.7 GHz • 3 V/m, 2 … 2.7 GHz • 10 V, 10 kHz … 80 MHz to IEC 61000-4-6 Immunity to magnetic fields • 100 A/m, 50/60 Hz to IEC 61000-4-8 Touch controller or • For PROFINET versions: 1 x Ethernet Only for device with expansions: 1 x PCIe-x4 expansion card can be used, max. permissible power loss: 5W Degree of protection Electromagnetic compatibility Interfaces COM 1 and COM 2 RS 232, max. 115 kbps, 9-pin, sub-D connector DVI Connection of VDUs with DVI connection Display port (DPP) Connection of VDUs with DPP connection Keyboard Connection via USB port Mouse Connection via USB port USB • Rear of device: 4 x USB 3.0, max. 2 high-current at the same time • Front of device (only with IPC477D with 15", 19" or 22" display): 1 x USB 2.0, high-current PROFIBUS/MPI • Transmission rate • Operating modes PROFINET 9-pole, 2 rows, electrically isolated, Sub-D socket, compatible with CP 5622 9.6 Kbps … 12 Mbps DP master: DP-V0, DP-V1 with SOFTNET-DP DP slave: DP-V0, DP-V1 with SOFTNET-DP slave 3 x RJ45 interface, CP 1616 compatible onboard interface based on ERTEC 400 10/100 Mbps, electrically isolated Weight • IPC477D, touch device, 12" display • IPC477D, touch device, 15" display • IPC477D, touch/key device (without expansions), 15" display • IPC477D, touch device, 19" display • IPC477D, touch device, 22" display Approx. 3200 g Approx. 4920 g Approx. 5750 g Approx. 6400 g Approx. 7000 g 3) For unambiguous labeling, the Ethernet ports are numbered on the enclosure. The numbering by the operating system can differ. 4) Teaming can be set and initiated in the configuration interface. In teaming operation, jumbo frames, e.g. for the camera application, are not supported Siemens ST 80 / ST PC · 2013 5/59 5 © Siemens AG 2013 PC-based Automation SIMATIC Panel PC SIMATIC IPC477D ■ Ordering data SIMATIC IPC477D Order No. 1) 6AV7240- 7 7 7 7 7 - 7 7 A 0 Processor and fieldbus: • Celeron U827E (1C/1T, 1.4 GHz, 1.5 MB cache); 2 x Gigabit Ethernet (IE/PN) • Celeron U827E (1C/1T, 1.4 GHz, 1.5 MB cache); 2 x Gigabit Ethernet (IE/PN); PROFIBUS DP12 • Core i3-3217UE (2C/4T, 1.6 GHz, 3 MB cache); 2 x Gigabit Ethernet (IE/PN) • Core i3-3217UE (2C/4T, 1.6 GHz, 3 MB cache); 2 x Gigabit Ethernet (IE/PN); PROFIBUS DP12 • Core i3-3217UE (2C/4T, 1.6 GHz, 3 MB cache); 1 x Gigabit Ethernet (IE/PN); 1 x PROFINET (IRT, 3 ports) • Core i7-3517UE (2C/4T, 1.7 (2.8) GHz, 3 MB cache); 2 x Gigabit Ethernet (IE/PN) • Core i7-3517UE (2C/4T, 1.7 (2.8) GHz, 3 MB cache); 2 x Gigabit Ethernet (IE/PN); PROFIBUS DP12 • Core i7-3517UE (2C/4T, 1.7 (2.8) GHz, 3 MB cache); 1 x Gigabit Ethernet (IE/PN); 1 x PROFINET (IRT, 3 ports) 5 Operator control unit: • 12" Touch (1280 x 800) (caution, restrictions regarding options: HDD, PCI, AC, DVD) • 15" Touch (1280 x 800) with front USB • 15" Touch/Key (1280 x 800) with front USB • 19" Touch (1366 x 768) with front USB • 22" Touch (1920 x 1080) with front USB Main memory/NVRAM: • 1 GB • 2 GB • 4 GB • 8 GB • 1 GB and NVRAM • 2 GB and NVRAM • 4 GB and NVRAM • 8 GB and NVRAM 1) Order No. Expansions/interface: • 1 x RS 232, without PCIe • 1 x RS 232 and 1 x PCIe • Second RS 232, without PCIe • Second RS 232 and 1 x PCIe 0 1 Operating system: • Without operating system • Windows Embedded Standard 7 SP1, English, 32-bit • Windows 7 Ultimate SP1, 32-bit, MUI (Eng, Ger, Fr, It, Sp) • Windows 7 Ultimate SP1, 64-bit, MUI (Eng, Ger, Fr, It, Sp) 3 4 5 Externally accessible mass storage (without operating system): • Without external mass storage • CFAST 2 GB, without software • CFAST 4 GB • CFAST 8 GB • CFAST 16 GB • DVD 6 7 Internal mass storage: • Without internal mass storage • CFAST 2 GB • CFAST 4 GB • CFAST 8 GB • CFAST 16 GB • SSD 50 GB High Endurance • SSD 80 GB Standard • HDD 250 GB • DVD • SSD 50 GB high endurance with DVD • SSD 80 GB standard with DVD 8 A B C D E • SSD 160 GB standard with DVD • HDD min. 250 GB with DVD A B C D J K L M Built to order versions with a delivery time of max. 15 working days and with identified repair. 5/60 Siemens ST 80 / ST PC · 2013 SIMATIC IPC477D (continued) 1) 6AV7240- 7 7 7 7 7 - 7 7 A 0 0 1 3 4 0 4 6 7 0 1 2 3 4 6 A B C D E G H K L M N P Q © Siemens AG 2013 PC-based Automation SIMATIC Panel PC SIMATIC IPC477D ■ Ordering data Order No. SIMATIC IPC477D 1) (continued) Order No. 6AV7240- 7 7 7 7 7 - 7 7 A 0 SIMATIC software preinstalled (bundles): • Without SIMATIC software • WinAC RTX 2010 2) • WinCC RT Advanced 128 PT • WinCC RT Advanced 512 PT • WinCC RT Advanced 2048 PT • WinCC RT Advanced 4096 PT • WinCC RT Advanced 128 PT, WinAC RTX 2) • WinCC RT Advanced 512 PT, WinAC RTX 2) • WinCC RT Advanced 2048 PT, WinAC RTX 2) • WinCC RT Advanced 4096 PT, WinAC RTX 2) • WinAC RTX 2010 F 2) • WinCC RT Advanced 128 PT, WinAC RTX F 2) • WinCC RT Advanced 512 PT, WinAC RTX F 2) • WinCC RT Advanced 2048 PT, WinAC RTX F 2) • WinCC RT Advanced 4096 PT, WinAC RTX F 2) SIMATIC IPC477D 1) (continued) 6AV7240- 7 7 7 7 7 - 7 7 A 0 Power supply: • 24 V DC industrial power supply • 110/230 V AC industrial power supply with Namur; no power cable • 110/230 V AC industrial power supply with Namur; European power cable • 110/230 V AC industrial power supply with Namur; US power cable • 110/230 V AC industrial power supply with Namur; Chinese power cable • 110/230 V AC industrial power supply with Namur; Italian power cable • 110/230 V AC industrial power supply with Namur; Swiss power cable • 110/230 V AC industrial power supply with Namur; UK power cable • 24 V DC industrial power supply and TPM (not for China and Russia) A B C D E F J K L M N P Q R S 0 1 2 3 4 5 6 7 8 1) Built to order versions with a delivery time of max. 15 working days and with identified repair. 2) Only with main memory and NVRAM. ■ Dimensional drawings All dimensions in mm. For mounting cut-out see technical specifications. 194.6 288.9 310 11 SIMATIC IPC477D 12" Touch device 75.5 6.2 82.2 2.3 G_ST80_XX_00524 11.2 2.3 81.6 393.9 372.4 G_ST80_XX_00523 6.2 38 11 415 25.5 330 308 276.4 68.2 39.1 4.6 241 219 178.7 5 SIMATIC IPC477D 15" Touch device Siemens ST 80 / ST PC · 2013 5/61 © Siemens AG 2013 PC-based Automation SIMATIC Panel PC SIMATIC IPC477D 194.6 289 68.2 310 194.6 82.2 337 316.9 ■ Dimensional drawings (continued) 483 483 426.9 372.4 38.2 448 372.4 SIMATIC IPC477D 15" Touch/Key device ■ More information Additional information is available in the Internet under: 103.8 5 194.6 380 360 http://www.siemens.com/simatic-panel-pc 560 84.2 540 372.4 SIMATIC IPC477D 22" Touch device 5/62 Siemens ST 80 / ST PC · 2013 81.6 G_ST80_XX_00526 25.5 6.2 75.5 2.3 G_ST80_XX_00527 75.5 6.2 G_ST80_XX_00525 81.6 75.5 25.5 6.2 SIMATIC IPC477D 19" Touch device 81.6 2.3 2.3 25.5 45.7 © Siemens AG 2013 PC-based Automation SIMATIC Panel PC SIMATIC HMI IPC477C ■ Overview SIMATIC HMI IPC477C: The powerful embedded Panel PC – maintenance-free with versatile configuration • Embedded PC platform with extremely high industrial compatibility for demanding tasks in the field of PC-based automation • Maintenance-free (no rotating components such as fan and hard disk) • Rugged construction: The PC is resistant to even the harshest mechanical stress and is extremely reliable in operation • Compact design (only 61-69 mm installation depth for 12"-19") • Battery-backed retentive memory onboard • High degree of investment security • Fast integration capability The following front versions are available: • Built-in versions - 12" and 15" TFT Touch - 12" and 15" TFT keypad - 19" Touch • Support arm versions - PRO 15" and PRO 19" Touch - Fully enclosed device with degree of protection IP65 for mounting on a support arm/stand ■ Technical specifications 6AV7 884-1....-...0 6AV7 884-2....-...0 6AV7 884-3....-...0 SIMATIC HMI IPC477C SIMATIC HMI IPC477C SIMATIC HMI IPC477C Operator control and monitoring Accessory components Slide-in keyboard labels Touch protective foil (not for Inox front) Slide-in keyboard labels Display Screen diagonal 12 in 15 in 15 in Resolution (pixels) • Resolution (WxH in pixel) 800 x 600 1024 x 768 1024 x 768 General features • Front panel 12" TFT Key 15" TFT Touch 15" TFT Key Backlighting • MTBF backlighting (at 25 °C) about 50,000 hours 50000 h about 50,000 hours Control elements Function keys 36 No 36 Mouse, at front Yes No Yes Keyboard fonts • Alphanumeric keyboard Yes No Yes Touch operation • Design as touch screen - Touch screen (analog/resistive) No No Yes Yes No No Installation type/mounting central design Yes Yes Yes Distributed design No No No 24 V DC: Max. 60 W (incl. USB interfaces) 140 W max. (15 W included per slot) 24 V DC: Max. 60 W (incl. USB interfaces) 450 mm x 290 mm/75 mm device depth 450x290 / 108 (incl. optical drive) 450 x 321 x 75 No drive planned. No drive planned. No drive planned. 6.6 kg 7 kg 7.2 kg Power losses Power loss in full configuration Dimensions Mounting cutout (W x H x D) additional mounting depth (optical drive) Weight Panel PC in central design, approx. Siemens ST 80 / ST PC · 2013 5 5/63 © Siemens AG 2013 PC-based Automation SIMATIC Panel PC SIMATIC HMI IPC477C ■ Ordering data Order No. Order No. SIMATIC HMI IPC477C and IPC477C PRO (built to order versions with a delivery time of max. 15 working days and with original part repair, if not preferred type). SIMATIC HMI IPC477C SIMATIC HMI IPC477C PRO (continued) 6AV7884- 7 A 7 7 7 - 7 7 7 0 SIMATIC HMI IPC477C PRO 0 1 2 3 5 6AV7883- 7 A 7 7 7 - 7 7 7 0 Embedded and fan-free with IP65 enclosure protected all-round; 5 x USB (500 mA), of which 1 x on the front, battery-backed retentive memory onboard, 24 V DC power supply with On/Off switch • 15" TFT Touch (IP65 enclosure) • 19" TFT Touch (IP65 enclosure) 5 Processors and fieldbus • Celeron M 1.2 GHz, 2 x PROFINET (IE) 1) • Celeron M 1.2 GHz, 2 x PROFINET (IE), 1 x PROFIBUS DP 12 1) • Core2 Solo 1.2 GHz, 2 x PROFINET (IE) 1) • Core2 Solo 1.2 GHz, 2 x PROFINET (IE), 1 x PROFIBUS 1) • Core2 Solo 1.2 GHz, 1 x PROFINET (IE), 1 x PROFINET (RT/IRT) (3 ports) • Core2 Duo 1.2 GHz, 2 x PROFINET (IE) 1) • Core2 Duo 1.2 GHz, 2 x PROFINET (IE), 1 x PROFIBUS 1) • Core2 Duo 1.2 GHz, 1 x PROFINET (IE), 1 x PROFINET (RT/IRT) (3 ports) Main memory (DDR3 RAM), 1 bank • 1 GB • 2 GB 1) • 4 GB 1 2 3 Second mass storage (installed and formatted) • Without1) • CompactFlash 2 GB 1) • CompactFlash 4 GB 1) • CompactFlash 8 GB 1) • CompactFlash 16 GB 1) • SSD High Endurance, min. 50 GB • SSD Standard, min. 80 GB (not for PRO version) Embedded and fan-free 5 x USB (500 mA), of which 1 x on the front, battery-backed retentive memory onboard, 24 V DC power supply with On/Off switch Front Panels • 12" TFT Touch 1) • 12" TFT Key • 15" TFT Touch 1) • 15" TFT Key • 19" TFT Touch 1) 6AV7883- 7 A 7 7 7 - 7 7 7 0 6 7 A B D E F 0 2 3 4 5 6 7 Mass storage (built-in, operating system pre-installed) • CompactFlash 2 GB (only with Windows Embedded Standard 2009) 1) • CompactFlash 4 GB 1) • CompactFlash 8 GB 1) • CompactFlash 16 GB 1) • SSD High Endurance, min. 50 GB • SSD Standard, min. 80 GB (not for PRO version) 2 3 4 5 6 7 Operating system (preinstalled and activated) • Windows Embedded Standard 2009 1) • Windows XP Professional Multi-Language, only with SSD; without SIMATIC software • Windows Embedded Standard 7 (only with CF > 4 GB or SSD and from 2 GB RAM) • Windows 7 Ultimate, MUI (Eng, Ger, Fr, It, Sp) only with SSD; without SIMATIC software SIMATIC HMI IPC477C (PRO) with SIMATIC software BA DA E A GA See Embedded bundles / Packages for industrial PCs G H J 1) Preferred types with replacement devices in exchange Note: Ready-to-use SIMATIC IPC477C (PRO) as bundles can be found under "Embedded bundles". Software packages with SIMATIC WinCC flexible, SIMATIC WinCC RT Advanced, SIMATIC WinCC, SIMATIC WinCC RT Professional, and SIMATIC WinAC RTX (F) can be ordered together with the SIMATIC IPC with a price advantage. More information under "Embedded bundles / Packages for industrial PCs". 5/64 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation SIMATIC Panel PC SIMATIC HMI IPC477C ■ Ordering data Order No. Order No. Accessories Protective film for Panel PCs 477/577/677 For protecting the touch screen against dirt/scratches • for 12" Touch • for 15" Touch (not for PRO) • for 19" Touch Labeling membranes for Panel PCs 477/577/677 For labeling soft keys and function keys, blank, supplied in sets of 10 6AV7671-2BA00-0AA0 6AV7671-4BA00-0AA0 6AV7672-1CE00-0AA0 Touch pen Captive pen for operation of the touch devices, mounting of the support on the control cabinet or directly on the PRO unit 6AV7672-1JB00-0AA0 Expansion components From page 5/153 6AV7672-0DA00-0AA0 Please be sure to note: The HMI IPC477C is delivered as standard with an inserted CF card. The licenses are on the supplied USB flash drive. Note: Further embedded versions based on IPC427C and Embedded Controller (mEC) are listed under SIMATIC PC-based Control. ■ Dimensional drawings 19.5 70.8 60.3 10.5 328 447.2 37.3 65.1 70.8 44 60.3 10.5 All dimensions in mm. For mounting cut-out see technical specifications. 328 366 482.6 G_ST80_XX_00396 59.15 4.8 207.5 288.3 G_ST80_XX_00395 4.8 310.3 207.5 59.15 SIMATIC HMI IPC477C 12" Key version 5 400 288.3 235 310.3 465 SIMATIC HMI IPC477C 12" Touch version Siemens ST 80 / ST PC · 2013 5/65 © Siemens AG 2013 PC-based Automation SIMATIC Panel PC SIMATIC HMI IPC477C 10.5 74.6 328 88.1 447.2 40.1 328 447.2 43.5 65.1 64.1 69.8 59.3 10.5 ■ Dimensional drawings (continued) 482.6 482.6 465 SIMATIC HMI IPC477C 19" Touch version ■ More information Additional information is available in the Internet under: http://www.siemens.com/simatic-panel-pc 5/66 Siemens ST 80 / ST PC · 2013 G_ST80_XX_00399 104 4.8 400 235 378 207.5 482.6 465 207.5 288.3 4.8 G_ST80_XX_00398 G_ST80_XX_00397 40.9 81 70.5 5 328 447.2 59.1 310.3 4.8 74.7 SIMATIC HMI IPC477C 15" Touch version 10.5 SIMATIC HMI IPC477C 15" Key version 88.1 235 207.5 354.8 235 319.4 465 © Siemens AG 2013 PC-based Automation SIMATIC Panel PC SIMATIC HMI IPC577C ■ Overview Rugged, expandable industry PC for demanding tasks in the area of PC-based automation with various control units (front panels): • Rugged and compact design for industrial use • Full PC openness - Windows Embedded Standard or Windows XP Professional, or without operating system - CF card, HDD, SSD - DVD drive • Expandable using a PCI slot • Optionally with PROFIBUS or PROFINET (RT/IRT) onboard • Installation-compatible with Panel PC 577B - Touch screen control units with 12", 15" and 19" TFT display - 12" and 15" TFT Key • High degree of investment protection ■ Technical specifications 6AV7 885-0....-.... SIMATIC HMI IPC577C 6AV7 885-1....-.... SIMATIC HMI IPC577C 6AV7 885-2....-.... SIMATIC HMI IPC577C 6AV7 885-3....-.... SIMATIC HMI IPC577C 6AV7 885-5....-.... SIMATIC HMI IPC577C Operator control and monitoring Accessory components Touch protective foil Slide-in keyboard labels Touch protective foil Slide-in keyboard labels Touch protective foil Display Screen diagonal 12 in 12 in 15 in 15 in 19 in Resolution (pixels) • Resolution (WxH in pixel) 800 x 600 800 x 600 1024 x 768 1024 x 768 1280 x 1024 General features • Front panel 12" TFT touch display 12" TFT Key 15" TFT touch display 15" TFT Key 19" TFT Touch Backlighting • MTBF backlighting (at 25 °C) about 50,000 hours about 50,000 hours about 50,000 hours about 50,000 hours about 50,000 hours Control elements Function keys No 36 No 36 No Mouse, at front No Yes No Yes No Keyboard fonts • Alphanumeric keyboard No Yes No Yes No Touch operation • Design as touch screen - Touch screen (analog/resistive) Yes Yes No No Yes Yes No No Yes Yes Installation type/mounting central design Yes Yes Yes Yes Yes Distributed design No No No No No 24 V DC: Max. 80 W (incl. USB interfaces) 24 V DC: Max. 80 W (incl. USB interfaces) 24 V DC: Max. 80 W (incl. USB interfaces) 24 V DC: Max. 80 W (incl. USB interfaces) 24 V DC: Max. 80 W (incl. USB interfaces) 368 x 290 x 115 450 x 290 x 115 450 x 290 x 120 450 x 321 x 115 450 x 380 x 125 23 mm 23 mm 23 mm 23 mm 23 mm 8.1 kg 8.6 kg 9 kg 9.3 kg 11.6 kg Power losses Power loss in full configuration Dimensions Mounting cutout (W x H x D) additional mounting depth (optical drive) Weight Panel PC in central design, approx. Siemens ST 80 / ST PC · 2013 5/67 5 © Siemens AG 2013 PC-based Automation SIMATIC Panel PC SIMATIC HMI IPC577C ■ Ordering data SIMATIC HMI IPC577C Order No. 6AV7885- 7 7 7 7 7 - 7 7 7 7 Front Panels • 12" TFT Touch • 12" TFT Key • 15" TFT Touch • 15" TFT Key • 19" TFT Touch Mainboards (processor with fieldbus interfaces) • Celeron M 1.2 GHz, 1 MB cache, 800 MHz FSB - with PROFINET (Industrial Ethernet); 2x LAN 1 Gbps • Core2 Solo 1.2 GHz, 3 MB cache, 800 MHz FSB - with PROFINET (Industrial Ethernet), 2x LAN 1 Gbps - with PROFIBUS DP12/MPI (CP5611-compatible), 2x LAN 1 Gbps - with PROFINET (RT/IRT) 3 ports, 1x LAN 1 Gbps • Core2 Duo 1.86 GHz, 6 MB cache, 1066 MHz FSB - with PROFINET (Industrial Ethernet), 2x LAN 1 Gbps - with PROFIBUS DP12/MPI (CP5611-compatible), 2x LAN 1 Gbps - with PROFINET (RT/IRT) 3 ports, 1x LAN 1 Gbps 5 RAM • 1 GB RAM, DDR3 • 2 GB RAM, DDR3 • 4 GB RAM, DDR3 Second mass storage and/or drive (formatted without operating system) • No second mass storage/drive • DVD-RW drive • HDD + DVD-RW drive • SSD 50 GB High Endurance+ DVD-RW drive • SSD 80 GB Standard+ DVD-RW drive • SSD 50 GB High Endurance • SSD 80 GB Standard • HDD min. 250 GB 1) Order No. SIMATIC HMI IPC577C (continued) First mass storage (formatted, optionally with operating system): • Without • HDD min. 250 GB (not if 2nd mass storage HDD or SSD) • 2 GB CompactFlash • 4 GB CompactFlash • 8 GB CompactFlash • 16 GB CompactFlash • SSD 50 GB High Endurance (not if 2nd mass storage HDD or SSD) • SSD 80 GB Standard (not if 2nd mass storage HDD or SSD) 0 1 2 3 5 AA Operating system (pre-installed on first mass storage) • Without operating system • Windows Embedded Standard • Windows XP Professional Multi-Language 1) • Windows Embedded Standard 7 • Windows 7 Ultimate Multi-Language 1) AD A E A F Expansion (software) • Without expansion • IPC DiagMonitor V4.3 enclosed • IPC Image & Partition Creator • IPC DiagMonitor V4.3 and Image & Partition Creator V3.2 enclosed AK A L AM 1 2 3 0 1 2 3 4 6 7 8 Multi-Language means: D/E/F/I/SP/CHIN traditional/CHIN simplified/ Korean/Japanese 6AV7885- 7 7 7 7 7 - 7 7 7 7 0 1 2 3 4 5 6 7 A B D E G A B C D Power supply • 100/240 V AC industrial power supply with Namur • 100/240 V AC industrial power supply with Namur; power cable for Europe • 100/240 V AC industrial power supply with Namur; power cable for the USA • 100/240 V AC industrial power supply with Namur; CN power cable • 100/240 V AC industrial power supply with Namur; IT power cable • 100/240 V AC industrial power supply with Namur; CH cable • 100/240 V AC industrial power supply with Namur; UK cable • 24 V DC industrial power supply Siemens ST 80 / ST PC · 2013 2 3 4 5 6 7 8 Note: Software Packages with SIMATIC WinCC flexible, SIMATIC WinCC and SIMATIC WinAC RTX (F) can be ordered together with the SIMATIC IPC with a price advantage. More information under "Embedded Bundles / Packages for industrial PCs". 5/68 1 © Siemens AG 2013 PC-based Automation SIMATIC Panel PC SIMATIC HMI IPC577C ■ Ordering data Order No. Order No. Accessories Protective film for SIMATIC HMI IPC577C For protecting the touch screen against dirt/scratches, set of 10 • for 12" Touch • for 15" Touch • for 19" Touch Labeling strips for Key devices For labeling soft keys and function keys, blank, supplied in sets of 10 6AV7671-2BA00-0AA0 6AV7671-4BA00-0AA0 6AV7672-1CE00-0AA0 Touch pen Captive pen for operation of the touch devices, mounting of the support on the control cabinet 6AV7672-1JB00-0AA0 Expansion components From page 5/153 Communication components From page 5/186 6AV7672-0DA00-0AA0 ■ Dimensional drawings 83.8 104.4 70.8 104.4 10.5 10.5 All dimensions in mm. For mounting cut-out see technical specifications. 354.4 482.6 465 SIMATIC HMI IPC577C 12" Key version 5 G_ST80_XX_00403 229 55.6 G_ST80_XX_00402 288.3 310.3 229 48.7 288.3 235 310.3 400 SIMATIC HMI IPC577C 12" Touch version Siemens ST 80 / ST PC · 2013 5/69 © Siemens AG 2013 PC-based Automation SIMATIC Panel PC SIMATIC HMI IPC577C 94 103.4 82.8 114.6 10.5 10.5 ■ Dimensional drawings (continued) 87.6 108.2 328 5 482.6 55.6 SIMATIC HMI IPC577C 15" Touch version ■ More information Additional information is available in the Internet under: http://www.siemens.com/simatic-panel-pc 5/70 Siemens ST 80 / ST PC · 2013 G_ST80_XX_00405 288.3 229 235 310.3 465 G_ST80_XX_00406 102.4 229 400 235 G_ST80_XX_00404 71.2 SIMATIC HMI IPC577C 19" Touch version 10.5 SIMATIC HMI IPC577C 15" Key version 378 465 229 483 465 319.4 482.6 235 354.8 354.4 © Siemens AG 2013 PC-based Automation SIMATIC Panel PC SIMATIC HMI IPC677C ■ Overview ■ Technical specifications SIMATIC HMI IPC677C General features SIMATIC HMI IPC677C: The high-end Panel PC – with maximum performance, functional scope and expansion capability • Compact design • High degree of investment security • Fast integration capability • Front panel versions: - 12", 15" and 19" TFT Touch - 12" and 15" TFT Key - 15" TFT Touch INOX with stainless steel front for special requirements, e.g. in the food, beverages and tobacco industries Processor • Intel Core i7-610E (2C/4T, 2.53 GHz, 4 MB L2, Turbo Boost, VT-d) • Intel Core i3-330E (2C/4T, 2.13 GHz, 3 MB L2) • Intel Celeron P4505 (2C/2T, 1.86 GHz, 2 MB L2) Main memory 1 GB, optionally 2, 3, 4 or 8 GB or 2, 4 or 8 GB with ECC Free slots for expansions • 2 x PCI (slot with card retainer) or 1 x PCI and 1 x PCIe x16 • 1 x slot for CompactFlash Card (accessible from outside) Operating system Different Windows operating systems incl. Windows 7 Ultimate 64-bit Power supply 24 V DC or 110/240 V AC (autorange), 50/60 Hz MTBF backlighting Typ. 50 000 h (at 24 h continuous operation, temperature-dependent) Drives Optical drives Optional DVD±RW±R combo drive, at the rear, operable from the side Hard disk/mass storage • 3.5" SATA hard disk ≥ 250 GB; • optional 3.5" SATA hard disk ≥ 500 GB, • Dual hard disk module 2 x ≥ 250 GB SATA as single disk configuration or RAID1 preconfigured, • 50 GB SSD (solid-state drive) 5 Siemens ST 80 / ST PC · 2013 5/71 © Siemens AG 2013 PC-based Automation SIMATIC Panel PC SIMATIC HMI IPC677C ■ Technical specifications (continued) SIMATIC HMI IPC677C Interfaces SIMATIC HMI IPC677C Certifications & standards Graphics interface DVI-I for additional display unit: Color depth 32 bits Connection for keyboard/mouse USB / USB Serial interface COM1: 1 x V.24 (RS232) PROFIBUS DP/MPI Onboard, isolated, max. 12 Mbit/s, compatible with CP 5611, not upgradeable PROFINET (IRT) Onboard, 3 x RJ 45, CP 1616-compatible, not upgradeable PROFINET (IE), Ethernet Onboard, 2 x 10/100/1000 Mbit USB 1 x on front, 4 x on rear, USB 2.0 (500 mA) Audio Possible via USB (external) Multimedia No Approvals CE, cULus(508) ATEX 22, UL Class 1 Div 2 (see front options) Shipbuilding approval (for configurations with CompactFlash or SSD memory and without optical drive) • • • • Expansion components Uninterruptible power supply (UPS), SIMATIC NET communication modules, SIMATIC IPC DiagMonitor, SIMATIC IPC Image & Partition Creator, SIMATIC IPC USB FlashDrive GL - Germanische Lloyd BV - Bureau Veritas LR - Lloyds Register of Shipping ABS - American Bureau of Shipping • DNV - Det Norske Veritas • NKK - Nippon Kaiji Kyokai Monitoring functions Temperature Yes Watchdog Yes Ambient conditions 5 Degree of protection IP65 (front) in accordance with EN 60529 and NEMA 4 Vibration load during operation Tested according to DIN IEC 60068-2-6: 10 - 58 Hz: 0.075 mm, 58 to 500 Hz: 10 m/s² (1 g) 2) Shock loading during operation Tested according to DIN IEC 60068-2-27: 50 m/s² (5 g), 30 ms, 100 shocks EMC CE, FCC A, 55022A, EN 61000-6-41), EN 61000-6-2 Ambient temperature during operation • 12"/15": 5 °C … +50 °C in maximum configuration • 19": 5 °C … +45 °C in maximum configuration Relative humidity Tested according to DIN IEC 60068-78, DIN IEC 60068-2-30: 5% to 80% at 25 °C (no condensation) Maximum permissible installation angle +/- 20° over vertical 5/72 Siemens ST 80 / ST PC · 2013 1) 61000-6-2 replaces 50082-2; 61000-6-4 replaces 50081-2 2) Valid with CF or SSD; with HDD: 5 g/0.5 g © Siemens AG 2013 PC-based Automation SIMATIC Panel PC SIMATIC HMI IPC677C ■ Ordering data SIMATIC HMI IPC677C Front panels • 12" TFT Touch • 12" TFT Key • 15" TFT Touch • 15" TFT Key • 19" TFT Touch Front options • With front USB interface • Without front USB interface • INOX front, without front USB, with 15" TFT Touch only • 19" TFT Touch with ATEX 22 and UL Class 1 Division 2 certification Power supply • 24 V DC • 110/230 V AC, power cable for Europe • 110/230 V AC, without power cable • 110/230 V AC, power cable for UK • 110/230 V AC, power cable for CH • 110/230 V AC, power cable for the USA • 110/230 V AC, power cable for Italy • 110/230 V AC, power cable for China Processor • Intel Celeron 1.86 GHz (2 Mbyte shared cache), 2 cores • Intel Celeron 1.86 GHz (2 MB shared cache), 2 cores, PROFIBUS MPI, 2 MB buffered SRAM • Intel Celeron 1.86 GHz (2 MB shared cache), 2 cores, PROFINET (3 x RJ45, CP1616-compatible), 2 MB buffered SRAM • Intel Core i3; 2.13 GHz (3 MB shared cache), 2 cores, hyper-threading • Intel Core i3; 2.13 GHz (3 MB shared cache), 2 cores, hyper-threading, PROFIBUS MPI, 2 MB buffered SRAM • Intel Core i3; 2.13 GHz (3 MB shared cache), 2 cores, hyper-threading, PROFINET (3 x RJ45, CP1616-compatible), 2 MB buffered SRAM • Intel Core i7; 2.53 GHz (4 MB shared cache), 2 cores, hyper-threading, turbo boost • Intel Core i7; 2.53 GHz (4 MB shared cache), 2 cores, hyper-threading, turbo boost, PROFIBUS MPI, 2 MB buffered SRAM • Intel Core i7; 2.53 GHz (4 MB shared cache), 2 cores, hyper-threading, turbo boost, PROFINET (3 x RJ45, CP 1616-compatible), 2 MB buffered SRAM Order No. Order No. 6AV789 7 - 7 7 7 7 7 - 7 7 7 7 Main memory • 1 GB DDR3 • 2 GB DDR3 • 3 GB DDR3 • 4 GB DDR3 • 8 GB DDR3 • 2 GB DDR3 with ECC • 4 GB DDR3 with ECC • 8 GB DDR3 with ECC 0 1 2 3 4 3 0 1 2 4 3 6AV789 7 - 7 7 7 7 7 - 7 7 7 7 SIMATIC HMI IPC677C (continued) 0 1 2 3 4 5 6 7 Mass storage • 250 GB SATA hard disk • 500 GB SATA hard disk • RAID1 dual hard disk module 2 x 250 GB SATA, preconfigured • Dual hard disk module 2 x 250 GB SATA • 50 GB SSD • Second CF card slot, internal, empty (not with Windows XP or Windows 7) instead of hard disk or SSD • Without mass memory A B C D E F G Optical drives • without • DVD±RW±R combo drive H A B C D E F G H 0 1 2 3 4 5 8 0 1 Communication interfaces • 2x PCI free • 1x PCI, 1x PCIe (x16) free A B Operating system (preinstalled and activated) • Without operating system • Windows XP Professional Multi-Language 1) • Windows 7 Ultimate 32 Bit Multi-Language 1) • Windows Embedded Standard on 8 GB CF card 2) • Windows 7 Ultimate 64 Bit Multi-Language 1) A B D E Software expansion • Without • SIMATIC IPC DiagMonitor V4.3 enclosed • SIMATIC IPC Image & Partition Creator V3.2 enclosed • SIMATIC IPC DiagMonitor V4.3, Image & Partition Creator V3.2 enclosed 1) Multi-Language means: D/E/F/I/SP/CHIN 2) Only without RAID 1 option 0 1 2 3 Note: J Software Packages with SIMATIC WinCC flexible, SIMATIC WinCC and SIMATIC WinAC RTX (F) can be ordered together with the SIMATIC IPC with a price advantage. More information under "Embedded Bundles / Packages for industrial PCs". Siemens ST 80 / ST PC · 2013 5 C 5/73 © Siemens AG 2013 PC-based Automation SIMATIC Panel PC SIMATIC HMI IPC677C ■ Ordering data Order No. Preferred versions 12" TFT Touch with Windows XP Prof. MUI, 110/230 V AC power supply, Core i3 2.13 GHz, 2 x PCI, 1 GB RAM, 250 GB HDD DVD±R/RW burner, PROFIBUS/MPI, NVRAM 6AV7890-0BE00-1AB0 12" TFT Key with Windows XP Prof. MUI, 110/230 V AC power supply, Core i3 2.13 GHz, 2 x PCI, 1 GB RAM, 250 GB HDD DVD±R/RW burner, PROFIBUS/MPI, NVRAM 6AV7891-0BE00-1AB0 15" TFT Touch with Windows XP Prof. MUI, 110/230 V AC power supply, Core i3 2.13 GHz, 2 x PCI, 1 GB RAM, 250 GB HDD DVD±R/RW burner, PROFIBUS/MPI, NVRAM 6AV7892-0BE00-1AB0 15" TFT Key with Windows XP Prof. MUI, 110/230 V AC power supply, Core i3 2.13 GHz, 2 x PCI, 1 GB RAM, 250 GB HDD DVD±R/RW burner, PROFIBUS/MPI, NVRAM 6AV7893-0BE00-1AB0 19" TFT Touch with Windows XP Prof. MUI, 110/230 V AC power supply, Core i3 2.13 GHz, 2 x PCI, 1 GB RAM, 250 GB HDD DVD±R/RW burner, PROFIBUS/MPI, NVRAM 6AV7894-0BE00-1AB0 5 5/74 Order No. Accessories Siemens ST 80 / ST PC · 2013 Protective film for Panel PCs 477/577/677/Flat Panel Set of 10, for protecting the touch screen against dirt/scratches • for 12" Touch • for 15" Touch • for 19" Touch Labeling strips for Panel PC 477/577/677 key devices For labeling soft keys and function keys, blank, supplied in sets of 10 Memory expansion • 1 GB DDR3 1066 SDRAM, DIMM • 2 GB DDR3 1066 SDRAM, DIMM • 4 GB DDR3 1066 SDRAM, DIMM • 1 GB DDR3 1066 SDRAM, DIMM, ECC • 2 GB DDR3 1066 SDRAM, DIMM, ECC • 4 GB DDR3 1066 SDRAM, DIMM, ECC Non-heating apparatus cable for SIMATIC Box and Panel PC SIMATIC PC power cable, 230 V AC, angled, 3 m, for: • Germany • United Kingdom • Switzerland • USA • Italy • China 6AV7671-2BA00-0AA0 6AV7671-4BA00-0AA0 6AV7672-1CE00-0AA0 6AV7672-0DA00-0AA0 6ES7648-2AJ40-0KA0 6ES7648-2AJ50-0KA0 6ES7648-2AJ60-0KA0 6ES7648-2AJ40-1KA0 6ES7648-2AJ50-1KA0 6ES7648-2AJ60-1KA0 6ES7900-1AA00-0XA0 6ES7900-1BA00-0XA0 6ES7900-1CA00-0XA0 6ES7900-1DA00-0XA0 6ES7900-1EA00-0XA0 6ES7900-1FA00-0XA0 Touch pen Captive pen for operation of the touch devices, mounting of the support on the control cabinet 6AV7672-1JB00-0AA0 Expansion components From page 5/153 Communication components From page 5/186 © Siemens AG 2013 PC-based Automation SIMATIC Panel PC SIMATIC HMI IPC677C ■ Dimensional drawings All dimensions in mm. For mounting cut-out see technical specifications. Operating units IPC 677 G H J K L M N • 12" 289 271 141 11 53 369 71 • 15" 289 271 138 11 24 367 42 • 19" 378 271 147 11 18 376 36 • 12" 289 271 122 11 42 351 59 • 15" 324 271 141 11 31 370 48 H G Touch devices Key devices M Note: All dimensions without screw clearances. K K L N G_ST80_XX_00288 J Operator control unit and overall device Front dimensions Installation cutout W H W+1 H+1 D • 12" 400 310 368 290 51 • 15" 483 310 450 290 55 • 19" 483 400 450 380 57 • 12" 483 310 450 290 • 15" 483 355 450 3211) H Touch devices Key devices W 1) In addition: Two cutouts 25 x 5 mm on the top for keyboard slide-in label channels. G_ST80_XX_00289 H+1 (cutout) W+1 (cutout) Installation cutout ■ More information Additional information is available in the Internet under: http://www.siemens.com/simatic-panel-pc Note Do you need a specific modification or option for the products described here? Under "Customized products", you will find information about additional sector-specific products that can be ordered as well as about options for customer-specific modification and adaptation. Siemens ST 80 / ST PC · 2013 5/75 5 © Siemens AG 2013 PC-based Automation SIMATIC PC-based controllers SIMATIC PC-based controllers ■ Overview SIMATIC PC-based Control • Adds PC-based controllers to the SIMATIC S7 controller family • Especially suitable where a variety of tasks such as data processing, communication, visualization, technology and control have to be integrated in one PC. Versions • SIMATIC WinAC Software PLC for tasks requiring a high level of flexibility and integration capability. • SIMATIC WinAC ODK allows PC solutions for technological tasks to be integrated flexibly and powerfully into the controller. Siemens has developed a wide range of coordinated hardware and software components for PC-based Automation. Focal point: SIMATIC PC-based Control with SIMATIC WinAC, the open, flexible and reliable controller for your PC-based automation solution. All automation tasks can be implemented on one platform on the PC, such as open-loop control, closed-loop control, HMI and motion control. PC-based Automation is your first choice wherever PC applications have to be handled in addition to classic PLC tasks. ■ More information Brochures 5 Information material for downloading can be found in the Internet: http://www.siemens.com/simatic/printmaterial 5/76 Siemens ST 80 / ST PC · 2013 Properties: • Runs on standard PCs under Windows XP Professional SP2. • Code-compatible with SIMATIC S7: Programmed with SIMATIC industrial software, created programs can also be used for SIMATIC S7. • Uses standard interfaces for integration into the office environment. • Open interfaces for the integration of solution-specific technological hardware and software. © Siemens AG 2013 PC-based Automation SIMATIC PC-based controllers SIMATIC WinAC RTX ■ Overview • SIMATIC WinAC RTX: Optimized for applications that require a high degree of flexibility and integration capability. • The software solution for tasks that require hard deterministic behavior and high performance. • With real-time expansion for assuring deterministic behavior for the control section. New with WinAC RTX 2010: • Operation under Windows 7 • Web server • New PROFINET functions: - Isochronous mode - Shared Device - Media redundancy - IP configuration ■ Technical specifications 6ES7671-0RC08-0YA0 6ES7671-0RC08-0YA0 SIMATIC WinAC RTX 2010 General information Hardware product version - Firmware version V4.6 Engineering with • Programming package Memory Work memory • integrated (for program) • integrated (for data) Load memory • integrated RAM, max. STEP7 as of V5.5 + HW update / iMap V3.0 SP1 4 Mbyte; Adjustable; depends on Non Paged Memory Pool 4 Mbyte; Adjustable; depends on Non Paged Memory Pool 8 Mbyte; Adjustable; depends on Non Paged Memory Pool CPU processing times for bit operations, typ. 0.004 µs; typ. for fixed point arithmetic, typ. 0.003 µs; typ. for floating point arithmetic, typ. 0.004 µs; typ. Reference platform Pentium IV, 2.4 GHz CPU-blocks DB • Number, max. • Size, max. FB • Number, max. • Size, max. FC • Number, max. 65 535; Limited only by RAM set for data 64 kbyte 65 536; Limited only by RAM set for code 64 kbyte • Size, max. 65 536; Limited only by RAM set for code 64 kbyte OB • Size, max. 64 kbyte Nesting depth • per priority class • additional within an error OB 24 24 SIMATIC WinAC RTX 2010 Counters, timers and their retentivity S7 counter • Number • Retentivity - adjustable - lower limit - upper limit - preset • Counting range - adjustable - lower limit - upper limit 2 048 Yes 0 2 047 8 Yes 0 999 IEC counter • present • Type • Number Yes SFB Unlimited (limited only by RAM capacity) S7 times • Number • Retentivity - adjustable - lower limit - upper limit - preset • Time range - lower limit - upper limit 2 048 Yes 0 2 047 0 10 ms 9 990 s IEC timer • present • Type • Number Yes SFB Unlimited (limited only by RAM capacity) Data areas and their retentivity Retentivity without UPS and PS Extension Board 128 kbyte with SIMATIC IPC427C and HMI IPC477C; further SIMATIC PCs on request Retentivity with UPS all data Flag • Number, max. • Retentivity preset • Number of clock memories 16 kbyte MB 0 to MB 15 8 Data blocks • Retentivity adjustable • Retentivity preset Yes; via non-retain property on DB Yes Siemens ST 80 / ST PC · 2013 5/77 5 © Siemens AG 2013 PC-based Automation SIMATIC PC-based controllers SIMATIC WinAC RTX ■ Technical specifications (continued) 6ES7671-0RC08-0YA0 6ES7671-0RC08-0YA0 SIMATIC WinAC RTX 2010 Local data • adjustable, max. • preset • per priority class, max. Address area I/O address area • Inputs • Outputs • of which, distributed - DP interface, inputs - DP interface, outputs - PN interface, inputs - PN interface, outputs 16 kbyte 16 kbyte 16 kbyte 16 kbyte 16 kbyte 16 kbyte Process image • Inputs, adjustable • Outputs, adjustable • Inputs, default • Outputs, default 8 kbyte 8 kbyte 512 byte 512 byte Subprocess images • Number of subprocess images, max. 15 Digital channels • Inputs • Outputs 128 000 128 000 Analog channels • Inputs • Outputs 8 000 8 000 Hardware configuration Submodules • Number of submodules, max • of which PROFIBUS, max. 5 64 kbyte 32 kbyte 61 440 byte • of which Industrial Ethernet, max. Number of operable FMs and CPs (recommended) • FM • CP, point-to-point • CP, LAN 4 4; Supported interfaces: see 1st and 2nd interface 1; Supported interfaces: see 3rd and 4th interface FM distributed: FM 350-1 / 350-2, FM 351, FM 352, FM 353, FM 355 / 355-2 2; CP 340, CP 341 distributed Over PC CP Time of day Clock • Hardware clock (real-time clock) • battery-backed and synchronizable Yes Yes Operating hours counter • Number 8 Clock synchronization • supported • to PC-CP, slave • on Ethernet via NTP Yes Yes Yes Interfaces Number of USB interfaces 0 1st interface Type of interface CP 5611-A2, CP 5621, integrated PB interface of the SIMATIC PC Max. no. of simultaneously operable CPs 1 Physics RS 485 / PROFIBUS Isolated Yes Power supply to interface (15 to 30 V DC), max. does not exist Number of connection resources 8 5/78 Siemens ST 80 / ST PC · 2013 SIMATIC WinAC RTX 2010 Functionality • MPI • DP master • DP slave DP master • Number of connections, max. • Transmission rate, max. • Number of DP slaves, max. • Services - PG/OP communication - Global data communication - S7 basic communication - S7 communication - S7 communication, as client - S7 communication, as server - Equidistance mode support - Isochronous mode - SYNC/FREEZE - Activation/deactivation of DP slaves - Direct data exchange (slave-to-slave communication) - DPV1 • Address area - Inputs, max. - Outputs, max. • User data per DP slave - Inputs, max. - Outputs, max. 2nd interface Type of interface No Yes No 8 12 Mbit/s 64 Yes No No Yes Yes Yes Yes; Only in conjunction with isochronous mode Yes Yes Yes Yes Yes 16 kbyte 16 kbyte 244 byte 244 byte CP 5613, CP 5613-A2, CP 5603 Max. no. of simultaneously operable CPs 4 Physics RS 485 / PROFIBUS Isolated Yes Functionality • MPI • DP master • DP slave No Yes No DP master • Number of connections, max. • Transmission rate, max. • Number of DP slaves, max. • Services - PG/OP communication - Global data communication - S7 basic communication - S7 communication - S7 communication, as client - S7 communication, as server - Equidistance mode support - Isochronous mode - SYNC/FREEZE - Activation/deactivation of DP slaves - Direct data exchange (slave-to-slave communication) - DPV1 • Address area - Inputs, max. - Outputs, max. • User data per DP slave - Inputs, max. - Outputs, max. 50 12 Mbit/s 125 Yes No No Yes Yes Yes Yes; Only in conjunction with isochronous mode Yes Yes Yes Yes Yes 16 kbyte 16 kbyte 244 byte 244 byte © Siemens AG 2013 PC-based Automation SIMATIC PC-based controllers SIMATIC WinAC RTX ■ Technical specifications (continued) 6ES7671-0RC08-0YA0 6ES7671-0RC08-0YA0 SIMATIC WinAC RTX 2010 3rd interface Type of interface PROFINET SIMATIC WinAC RTX 2010 4th interface Type of interface PROFINET 1; Intel Pro/1000 (Intel 82571EB, 82573L, 82574L, 82541PI; non-shared IRQ required); integrated IE interface SIMATIC PC 4x7B, 6x7B, 8x7B, IPC4x7C, IPC6x7C, IPC8x7C Max. no. of simultaneously operable CPs 1; CP 1616 (HW release 8 or above), CP 1604 (HW release 7 or higher), integrated PN interface of SIMATIC PC and S7-mEC Physics Ethernet Ethernet Isolated Yes Yes Integrated switch Yes No Number of ports 3 Number of ports 1 Automatic detection of transmission speed Yes; 10/100 Mbit/s Automatic detection of transmission speed Yes; 10/100 Mbit/s Autonegotiation Yes Yes Autocrossing Yes Autocrossing Yes Change of IP address at runtime, supported Yes Media redundancy • supported No Number of connection resources 32 Max. no. of simultaneously operable CPs Physics Isolated Integrated switch Autonegotiation Functionality • PROFINET IO Controller • PROFINET IO Device • PROFINET CBA PROFINET IO Controller • Transmission rate, min. • Transmission rate, max. • Max. number of connectable IO devices for RT - of which in line, max. • IRT, supported • Prioritized startup supported - Number of IO Devices, max. • Activation/deactivation of IO Devices - Maximum number of IO devices that can be activated/deactivated at the same time. • IO Devices changing during operation (partner ports), supported • Device replacement without swap medium • Send cycles • Updating time • Services - PG/OP communication - S7 communication - Isochronous mode - Open IE communication • Address area - Inputs, max. - Outputs, max. - User data per address area, max. - User data consistency, max. Open IE communication • Open IE communication, supported • Number of connections, max. • Local port numbers used at the system end • Keep-alive function, supported Yes No Yes Media redundancy • supported • Switchover time on line break, typically • Number of stations in the ring, max. 100 Mbit/s 100 Mbit/s 128 Functionality • PROFINET IO Controller • PROFINET IO Device • PROFINET CBA 128 No Yes 32 Yes 8 Yes Yes 1 ms 1 - 512 ms (minimum value depends on communication share set for PROFINET I/O, on the number of I/O devices, and on the volume of configured user data) Yes Yes No Yes 16 kbyte 16 kbyte 2 kbyte 256 byte Yes 32 0, 20, 21, 23, 25, 80, 102, 135, 161, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535 Yes Yes 200 ms 50 Yes No Yes PROFINET IO Controller • Transmission rate, max. • Max. number of connectable IO Devices for RT - of which in line, max. • Number of IO devices with IRT and the option "high flexibility" - of which in line, max. • Number of IO Devices with IRT and the option "high performance", max. - of which in line, max. • IRT, supported • Prioritized startup supported - Number of IO Devices, max. • Activation/deactivation of IO Devices - Maximum number of IO devices that can be activated/deactivated at the same time. • IO Devices changing during operation (partner ports), supported • Device replacement without swap medium • Send cycles • Updating time • Services - PG/OP communication - S7 communication - Isochronous mode - Open IE communication • Address area - Inputs, max. - Outputs, max. - User data per address area, max. - User data consistency, max. 100 Mbit/s 256 5 256 64 32 64 32 Yes Yes 32 Yes 8 Yes Yes 250 µs, 500 µs, 1 ms 0.25...512 depending on the send cycle Yes Yes Yes Yes 16 kbyte 16 kbyte 2 kbyte 256 byte Siemens ST 80 / ST PC · 2013 5/79 © Siemens AG 2013 PC-based Automation SIMATIC PC-based controllers SIMATIC WinAC RTX ■ Technical specifications (continued) 6ES7671-0RC08-0YA0 6ES7671-0RC08-0YA0 SIMATIC WinAC RTX 2010 Open IE communication • Open IE communication, supported • Number of connections, max. • Local port numbers used at the system end Isochronous mode Isochronous operation (application synchronized up to terminal) Yes Number of DP masters with isochronous mode 2 User data per isochronous slave, max. 128 byte equidistance Yes shortest clock pulse 2.2 ms; 2.2 ms without partial p rocess image; 2.2 ms with partial process image Communication functions PG/OP communication Data record routing Yes Yes; Only with CP 5611 or integrated PROFIBUS interface of the SIMATIC PC Global data communication • supported No S7 basic communication • supported No S7 communication • supported • as server • as client • User data per job, max. 5 Yes 32 0, 20, 21, 25, 80, 102, 135, 161, 34962, 34963, 34964, 65532, 65533, 65534, 65535 Open IE communication • TCP/IP - Number of connections, max. - Data length for connection type 01H, max. - Data length for connection type 11H, max. - Data length, max. • ISO-on-TCP (RFC1006) - Number of connections, max. - Data length, max. • UDP - Number of connections, max. - Data length, max. Web server • supported • Number of HTTP clients • User-defined websites Yes Yes Yes 64 kbyte; When using BSEND/USEND Yes 32 Not supported 65 534 byte 65 534 byte Yes 32 65 534 byte Yes 32 1 472 byte Yes 2 No SIMATIC WinAC RTX 2010 PROFINET CBA (at set setpoint communication load) • Setpoint for the CPU communication load • Number of remote interconnection partners • Number of functions, master/slave • Total of all Master/Slave connections • Data length of all incoming connections master/slave, max. • Data length of all outgoing connections master/slave, max. • Number of device-internal and PROFIBUS interconnections • Data length of device-internal und PROFIBUS interconnections, max. • Data length per connection, max. • Remote interconnections with acyclic transmission - Sampling frequency: Sampling time, min. - Number of incoming interconnections - Number of outgoing interconnections - Data length of all incoming interconnections, max. - Data length of all outgoing interconnections, max. - Data length per connection, max. • Remote interconnections with cyclic transmission - Transmission frequency: Transmission interval, min. - Number of incoming interconnections - Number of outgoing interconnections - Data length of all incoming interconnections, max. - Data length of all outgoing interconnections, max. - Data length per connection, max. • HMI variables via PROFINET (acyclic) - Number of stations that can log on for HMI variables (PN OPC/iMap) - HMI variable updating - Number of HMI variables - Data length of all HMI variables, max. • PROFIBUS proxy functionality - supported - Number of linked PROFIBUS devices - Data length per connection, max. Number of connections • overall 5/80 Siemens ST 80 / ST PC · 2013 20 % 64 30 1 000 6 800 byte 6 800 byte 500 4 000 byte 1 400 byte 500 ms 100 100 2 000 byte 2 000 byte 1 400 byte 10 ms 200 200 4 800 byte 4 800 byte 250 byte 3 500 ms 200 2 000 byte Yes 16 240 byte; Slave-dependent 96 © Siemens AG 2013 PC-based Automation SIMATIC PC-based controllers SIMATIC WinAC RTX ■ Technical specifications (continued) 6ES7671-0RC08-0YA0 6ES7671-0RC08-0YA0 SIMATIC WinAC RTX 2010 S7 message functions Number of login stations for message functions, max. 62 SCAN procedure No Process diagnostic messages Yes; ALARM_S, ALARM_SQ, ALARM_D, ALARM_DQ simultaneously active Alarm-S blocks, max. 20; of a total of 20 for all SFCs Alarm 8-blocks • Number of instances for alarm 8 and S7 communication blocks, max. Yes 4 000 Process control messages No Test commissioning functions Status block Yes Single step Yes Number of breakpoints 20 Status/control • Status/control variable Yes Forcing • Forcing No Diagnostic buffer • present • Number of entries, max. - adjustable - preset Yes 3 200 Yes 120 Hardware requirements Hardware required PC with color monitor, keyboard, mouse or pointing device for Windows Required memory on hard disk, min. 100 Mbyte Main memory, min. 1 Gbyte; WES7: 2 GB Processor Intel Celeron M, 900 MHz or compatible Yes; Dual Pentium, CoreDuo, Core2Duo or compatible Yes • Multi-processor system • Hyper-threading SIMATIC WinAC RTX 2010 Operating systems Windows NT 4.0 No Windows 2000 No Windows XP Yes; Professional, SP2 and SP3 Windows XP embedded Yes; With the delivery image of the SIMATIC PC ACPI uniprocessor PC, ACPI multiprocessor PC, MPS multiprocessor PC • Supported HAL types under Windows XP Windows Vista No Windows 7 Yes; Professional, Enterprise, Ultimate (only 32 bits) Windows embedded Standard 7 Yes Configuration programming • Nesting levels • Programming language - LAD - FBD - STL - SCL - CFC - GRAPH - HiGraph® • Software libraries - Easy Motion Control 8 Yes Yes Yes Yes Yes Yes Yes Yes Know-how protection • User program protection/password protection Open Development interfaces • CCX (Custom Code Extension) • CMI (Controller Management Interface) • SMX (Shared Memory Extension) - Inputs - Outputs Weight Weight, approx. Yes Yes; WinAC ODK V4.2 or higher Yes; WinAC ODK V4.2 or higher Yes; WinAC ODK V4.2 or higher 4 kbyte 4 kbyte 100 g; With packaging Siemens ST 80 / ST PC · 2013 5/81 5 © Siemens AG 2013 PC-based Automation SIMATIC PC-based controllers SIMATIC WinAC RTX ■ Ordering data SIMATIC WinAC RTX 2010 Order No. 6ES7671-0RC08-0YA0 Software PLC for PC-based automation tasks with stringent deterministic requirements; PROFIBUS and PROFINET; CD-ROM with electronic documentation d, e, f; single license, executable under Windows XP SP2 and SP3 as well as Windows 7 (32 bit) SIMATIC WinAC RTX 2010 Upgrade 6ES7671-0RC08-0YE0 For upgrading from basic/RTX V3.x, V4.0, V4.1 2005, 2008 and 2009; single license, executable under Windows XP SP2 and SP3 and Windows 7 (32 bit) CP 5611 A2 communications processor 6GK1561-1AA01 CP 5603 Microbox Package 6GK1562-1AA00 6GK1560-3AU00 Comprising CP 5603 module and Microbox expansion rack CP 5613 A2 communications processor 5 6GK1561-3AA01 PCI card (32 bit; 3.3 V/5 V) for connection to PROFIBUS incl. DP-Base software with NCM PC; DP-RAM interface for DP master, incl. PG and FDL protocol; single license for 1 installation, runtime software, software and electronic manual on CD-ROM, Class A, for 32 bit Windows 2000 Professional/ Server, Windows XP Professional, German/English 5/82 Siemens ST 80 / ST PC · 2013 6GK1161-6AA02 PCI Card (32 bit; 3.3/5 V universal key) with ASIC ERTEC 400 for connecting PCs to PROFINET IO with 4-port real-time switch (RJ45); incl. IO-Base software for PROFINET IO controller (RT operation) and NCM PC; single license for one installation, runtime software, software and electronic manual on CD-ROM, Class A, for 32 bit Windows XP Professional; German/English CP 1604 Microbox Package 6GK1562-1AM00 6GK1562-3AA00 PCI Express x1 card (32 bit) for connection to PROFIBUS incl. DP-Base software with NCM PC; DP-RAM interface for DP master or DP slave, incl. PG and FDL protocols; single license for 1 installation, runtime software, software and electronic manual on CD-ROM, Class A, for operating system support see SIMATIC NET software; German/English CP 1616 communications processor PCI card (32 bit) for connection of a programming device or PC to PROFIBUS CP 5621 communications processor • PCI Express x1 card (32 bit) for connection of a programming device or PC to PROFIBUS • PCI Express x1 card (32 bit) CP 5621 and MPI cable, 5 m Order No. CP 5623 communications processor Package for implementing the CP 1604 in the SIMATIC Microbox PC; comprising the CP 1604, connection board, power supply and expansion rack for Microbox PC; for use with Development Kit DK-16xx PN IO; NCM PC 6GK1160-4AU00 © Siemens AG 2013 PC-based Automation SIMATIC PC-based controllers SIMATIC WinAC RTX ■ More information Add-ons for SIMATIC WinAC Application Function PC-based Competence Center Cologne WinAC serial driver Our add-ons supplement the WinAC RTX soft PLC by useful functions which have arisen in the context of projects. You can thus fully utilize the advantages of PC-based automation. Communication over serial interfaces WinAC PC IO driver Access to central I/O expansion PC IO including interrupt handling WinAC SQL Access to SQL databases WinAC TCP/IP driver Data exchange between WinAC and other communication partners over Windows interface using TCP/IP, UDP, or ISO-on-TCP WinAC OPC Client Access to various OPC servers WinAC Shutdown Controlled shutdown of WinAC and PC system WinAC File-I/O Reading and writing of DBs as file on the PC system WinAC Command Calling of batch commands from WinAC WinAC Access-DB High-performance access to DBs, bit memories or I/O image WinAC SMX Cover Provision of SMX functions, e.g. for Delphi or VB WinAC CMI Wrapper Simple program-based operation of WinAC The applications are available in the form of function blocks and are easy to use without special programming knowledge. Detailed information and prices can be obtained from your Siemens contact or from: Contact: Siemens AG Competence Center Cologne E-mail: CCCologne@siemens.com Brochures Information material for downloading can be found in the Internet: http://www.siemens.com/simatic/printmaterial 5 Siemens ST 80 / ST PC · 2013 5/83 © Siemens AG 2013 PC-based Automation SIMATIC PC-based controllers SIMATIC WinAC RTX F ■ Overview ■ Technical specifications 6ES7671-1RC08-0YA0 SIMATIC WinAC RTX F 2010 General information Hardware product version - Firmware version V4.6 Engineering with • Programming package Memory Work memory • integrated (for program) • integrated (for data) Load memory • integrated RAM, max. • SIMATIC WinAC RTX F: Optimized for applications that demand a high degree of flexibility and integration capability and that must also satisfy safety requirements up to SIL 3 (IEC 61508). • The software solution for tasks that require hard deterministic behavior and high performance. • With real-time expansion for assuring deterministic behavior for the control section. • Distributed I/O can be connected over PROFIBUS and/or PROFINET, also safety-related over PROFIsafe. for fixed point arithmetic, typ. 0.003 µs; typ. for floating point arithmetic, typ. 0.004 µs; typ. Reference platform Pentium IV, 2.4 GHz CPU-blocks DB • Number, max. • Size, max. FC • Number, max. 65 535; Limited only by RAM set for data 64 kbyte 65 536; Limited only by RAM set for code 64 kbyte • Size, max. 65 536; Limited only by RAM set for code 64 kbyte OB • Size, max. 64 kbyte Nesting depth • per priority class • additional within an error OB 24 24 Counters, timers and their retentivity S7 counter • Number • Retentivity - adjustable - lower limit - upper limit - preset • Counting range - adjustable - lower limit - upper limit IEC counter • present • Type • Number Siemens ST 80 / ST PC · 2013 Adjustable; depends on Non Paged Memory Pool 0.004 µs; typ. FB • Number, max. 5/84 4 Mbyte; Adjustable; depends on Non Paged Memory Pool 4 Mbyte; Adjustable; depends on Non Paged Memory Pool CPU processing times for bit operations, typ. • Size, max. 5 STEP 7 V5.5 or higher + hardware update / iMap V3.0 SP1 / option package S7 Distributed Safety V5.4 + SP5 / S7 F Configuration Pack V5.5 + SP6 + HF1 2 048 Yes 0 2 047 8 Yes 0 999 Yes SFB Unlimited (limited only by RAM capacity) © Siemens AG 2013 PC-based Automation SIMATIC PC-based controllers SIMATIC WinAC RTX F ■ Technical specifications (continued) 6ES7671-1RC08-0YA0 6ES7671-1RC08-0YA0 SIMATIC WinAC RTX F 2010 S7 times • Number • Retentivity - adjustable - lower limit - upper limit - preset • Time range - lower limit - upper limit 2 048 Yes 0 2 047 0 10 ms 9 990 s SIMATIC WinAC RTX F 2010 Hardware configuration Submodules • Number of submodules, max • of which PROFIBUS, max. • of which Industrial Ethernet, max. Number of operable FMs and CPs (recommended) • FM 4 4; Supported interfaces: see 1st and 2nd interface 1; Supported interfaces: see 3rd and 4th interface • CP, point-to-point • CP, LAN 4; FM distributed: FM 350-1, FM 350-2, FM 351, FM 352 / FM 352-5, FM 353, FM 354, FM 355, FM 355-2 2; CP 340, CP 341 distributed Over PC CP Time of day Clock • Hardware clock (real-time clock) • battery-backed and synchronizable Yes Yes all data Operating hours counter • Number 8 Flag • Number, max. • Retentivity preset • Number of clock memories 16 kbyte MB 0 to MB 15 8 Clock synchronization • supported • to PC-CP, slave • on Ethernet via NTP Yes Yes Yes Data blocks • Retentivity adjustable • Retentivity preset Yes; via non-retain property on DB Yes Local data • adjustable, max. • preset • per priority class, max. 64 kbyte 32 kbyte 61 440 byte IEC timer • present • Type • Number Data areas and their retentivity Retentivity without UPS and PS Extension Board Retentivity with UPS Address area I/O address area • Inputs • Outputs • of which, distributed - DP interface, inputs - DP interface, outputs - PN interface, inputs - PN interface, outputs Yes SFB Unlimited (limited only by RAM capacity) 128 kbyte with SIMATIC IPC427C and HMI IPC477C; further SIMATIC PCs on request 16 kbyte 16 kbyte 16 kbyte 16 kbyte 16 kbyte 16 kbyte Process image • Inputs, adjustable • Outputs, adjustable • Inputs, default • Outputs, default 8 kbyte 8 kbyte 512 byte 512 byte Subprocess images • Number of subprocess images, max. 15 Digital channels • Inputs • Outputs 128 000 128 000 Analog channels • Inputs • Outputs 8 000 8 000 1st interface Type of interface CP 5611-A2, CP 5621, integrated PB interface of the SIMATIC PC Max. no. of simultaneously operable CPs 1 Physics RS 485 / PROFIBUS Isolated Yes Power supply to interface (15 to 30 V DC), max. does not exist Number of connection resources 8 Functionality • MPI • DP master • DP slave No Yes No DP master • Number of connections, max. • Transmission rate, max. • Number of DP slaves, max. • Services - PG/OP communication - Global data communication - S7 basic communication - S7 communication - S7 communication, as client - S7 communication, as server - Equidistance mode support - Isochronous mode - SYNC/FREEZE - Activation/deactivation of DP slaves - Direct data exchange (slave-toslave communication) - DPV1 • Address area - Inputs, max. - Outputs, max. • User data per DP slave - Inputs, max. - Outputs, max. 5 8 12 Mbit/s 64 Yes No No Yes Yes Yes Yes; Only in conjunction with isochronous mode Yes Yes Yes Yes Yes 16 kbyte 16 kbyte 244 byte 244 byte Siemens ST 80 / ST PC · 2013 5/85 © Siemens AG 2013 PC-based Automation SIMATIC PC-based controllers SIMATIC WinAC RTX F ■ Technical specifications (continued) 6ES7671-1RC08-0YA0 6ES7671-1RC08-0YA0 SIMATIC WinAC RTX F 2010 2nd interface Type of interface Max. no. of simultaneously operable CPs 4 Physics RS 485 / PROFIBUS Isolated Yes Functionality • MPI • DP master • DP slave No Yes No DP master • Number of connections, max. • Transmission rate, max. • Number of DP slaves, max. • Services - PG/OP communication - Global data communication - S7 basic communication - S7 communication - S7 communication, as client - S7 communication, as server - Equidistance mode support 5 CP 5613, CP 5613-A2, CP 5603, CP 5623 - Isochronous mode - SYNC/FREEZE - Activation/deactivation of DP slaves - Direct data exchange (slave-to-slave communication) - DPV1 • Address area - Inputs, max. - Outputs, max. • User data per DP slave - Inputs, max. - Outputs, max. 3rd interface Type of interface Max. no. of simultaneously operable CPs 50 12 Mbit/s 125 Yes No No Yes Yes Yes Yes; Only in conjunction with isochronous mode Yes Yes Yes Yes Yes 16 kbyte 16 kbyte 244 byte 244 byte SIMATIC WinAC RTX F 2010 PROFINET IO Controller • Transmission rate, min. • Transmission rate, max. • Number of connectable IO devices, max. • Max. number of connectable IO devices for RT - of which in line, max. • IRT, supported • Prioritized startup supported - Number of IO Devices, max. • Activation/deactivation of IO Devices - Maximum number of IO devices that can be activated/deactivated at the same time. • IO Devices changing during operation (partner ports), supported • Device replacement without swap medium • Send cycles • Updating time • Services - PG/OP communication - S7 communication - Isochronous mode - Open IE communication • Address area - Inputs, max. - Outputs, max. - User data per address area, max. - User data consistency, max. Open IE communication • Open IE communication, supported • Number of connections, max. • Local port numbers used at the system end 128 128 No Yes 32 Yes 8 Yes Yes 1 ms 1 - 512 ms (minimum value depends on communication share set for PROFINET I/O, on the number of I/O devices, and on the volume of configured user data) Yes Yes No Yes 16 kbyte 16 kbyte 2 kbyte 256 byte • Keep-alive function, supported Yes 32 0, 20, 21, 23, 25, 80, 102, 135, 161, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535 Yes 4th interface Type of interface PROFINET PROFINET 1; Intel Pro/1000 (Intel 82571EB, 82573L, 82574L, 82541PI; non-shared IRQ required); integrated IE interface SIMATIC PC 4x7B, 6x7B, 8x7B, IPC4x7C, IPC6x7C, IPC8x7C 100 Mbit/s 100 Mbit/s 128 Max. no. of simultaneously operable CPs 1; CP 1616 (HW release 8 or above), CP 1604 (HW release 7 or higher), integrated PN interface of SIMATIC PC and S7-mEC Physics Ethernet Isolated Yes Physics Ethernet Integrated switch No Isolated Yes Number of ports 1 Integrated switch Yes Automatic detection of transmission speed Yes; 10/100 Mbit/s Number of ports 3 Autonegotiation Yes Automatic detection of transmission speed Yes; 10/100 Mbit/s Autocrossing Yes Autonegotiation Yes Autocrossing Yes Change of IP address at runtime, supported Yes Number of connection resources 32 Media redundancy • supported No Functionality • PROFINET IO Controller • PROFINET IO Device • PROFINET CBA Yes No Yes 5/86 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation SIMATIC PC-based controllers SIMATIC WinAC RTX F ■ Technical specifications (continued) 6ES7671-1RC08-0YA0 6ES7671-1RC08-0YA0 SIMATIC WinAC RTX F 2010 Media redundancy • supported • Switchover time on line break, typically • Number of stations in the ring, max. Functionality • PROFINET IO Controller • PROFINET IO Device • PROFINET CBA PROFINET IO Controller • Transmission rate, max. • Max. number of connectable IO Devices for RT - of which in line, max. • Number of IO devices with IRT and the option "high flexibility" - of which in line, max. • Number of IO Devices with IRT and the option "high performance", max. - of which in line, max. • IRT, supported • Prioritized startup supported - Number of IO Devices, max. • Activation/deactivation of IO Devices - Maximum number of IO devices that can be activated/deactivated at the same time. • IO Devices changing during operation (partner ports), supported • Device replacement without swap medium • Send cycles • Updating time • Services - PG/OP communication - S7 communication - Isochronous mode - Open IE communication • Address area - Inputs, max. - Outputs, max. - User data per address area, max. - User data consistency, max. Open IE communication • Open IE communication, supported • Number of connections, max. • Local port numbers used at the system end Isochronous mode Isochronous operation (application synchronized up to terminal) Yes 200 ms SIMATIC WinAC RTX F 2010 Communication functions PG/OP communication Yes Yes; Only with CP 5611 or integrated PROFIBUS interface of the SIMATIC PC Data record routing 50 Yes No Yes 100 Mbit/s 256 256 64 32 64 64 Yes Yes 32 Yes 8 Yes Yes Global data communication • supported No S7 basic communication • supported No S7 communication • supported • as server • as client • User data per job, max. Yes Yes Yes 64 kbyte; Depends on which block is used: BSEND/USEND or PUT/GET Open IE communication • TCP/IP - Number of connections, max. - Data length for connection type 01H, max. - Data length for connection type 11H, max. - Data length, max. • ISO-on-TCP (RFC1006) - Number of connections, max. - Data length, max. • UDP - Number of connections, max. - Data length, max. 250 µs, 500 µs, 1 ms 0.25...512 depending on the send cycle Web server • supported • Number of HTTP clients • User-defined websites Yes Yes Yes Yes PROFINET CBA (at set setpoint communication load) • Setpoint for the CPU communication load • Number of remote interconnection partners • Number of functions, master/slave • Total of all Master/Slave connections • Data length of all incoming connections master/slave, max. • Data length of all outgoing connections master/slave, max. • Number of device-internal and PROFIBUS interconnections • Data length of device-internal und PROFIBUS interconnections, max. • Data length per connection, max. • Remote interconnections with acyclic transmission - Sampling frequency: Sampling time, min. - Number of incoming interconnections - Number of outgoing interconnections - Data length of all incoming interconnections, max. - Data length of all outgoing interconnections, max. - Data length per connection, max. 16 kbyte 16 kbyte 2 kbyte 256 byte Yes 32 0, 20, 21, 25, 80, 102, 135, 161, 34962, 34963, 34964, 65532, 65533, 65534, 65535 Yes Number of DP masters with isochronous mode 2 User data per isochronous slave, max. 128 byte equidistance Yes shortest clock pulse 2.2 ms; 2.2 ms without partial process image; 2.2 ms with partial process image Yes 32 Not supported 65 534 byte 65 534 byte Yes 32 65 534 byte Yes 32 1 472 byte Yes 2 No 5 20 % 64 30 1 000 6 800 byte 6 800 byte 500 4 000 byte 1 400 byte 500 ms 100 100 2 000 byte 2 000 byte 1 400 byte Siemens ST 80 / ST PC · 2013 5/87 © Siemens AG 2013 PC-based Automation SIMATIC PC-based controllers SIMATIC WinAC RTX F ■ Technical specifications (continued) 6ES7671-1RC08-0YA0 6ES7671-1RC08-0YA0 SIMATIC WinAC RTX F 2010 • Remote interconnections with cyclic transmission - Transmission frequency: Transmission interval, min. - Number of incoming interconnections - Number of outgoing interconnections - Data length of all incoming interconnections, max. - Data length of all outgoing interconnections, max. - Data length per connection, max. • HMI variables via PROFINET (acyclic) - Number of stations that can log on for HMI variables (PN OPC/iMap) - HMI variable updating - Number of HMI variables - Data length of all HMI variables, max. • PROFIBUS proxy functionality - supported - Number of linked PROFIBUS devices - Data length per connection, max. Number of connections • overall 5 10 ms PC with color monitor, keyboard, mouse or pointing device for Windows 200 Required memory on hard disk, min. 100 Mbyte 200 Main memory, min. 1 Gbyte Processor • Multi-processor system • Hyper-threading Intel Celeron M 900 MHz or compatible (older PC systems with Programmable Interrupt Controllers (PIC) are not suitable for WinAC RTX F 2010.) No Yes Operating systems Windows NT 4.0 No 500 ms 200 2 000 byte Windows 2000 No Windows XP Yes; Professional, SP2 and SP3 Windows XP embedded Yes 16 • Supported HAL types under Windows XP Yes; With the delivery image of the SIMATIC PC ACPI uniprocessor PC, ACPI multiprocessor PC, MPS multiprocessor PC 240 byte; Slave-dependent Windows Vista No Windows 7 Yes; Professional, Enterprise, Ultimate (only 32 bits) Windows embedded Standard 7 No 4 800 byte 4 800 byte 250 byte 3 96 S7 message functions Number of login stations for message functions, max. 62 SCAN procedure No Process diagnostic messages Yes; ALARM_S, ALARM_SQ, ALARM_D, ALARM_DQ simultaneously active Alarm-S blocks, max. 20; of a total of 20 for all SFCs Alarm 8-blocks • Number of instances for alarm 8 and S7 communication blocks, max. Yes 4 000 Process control messages No Test commissioning functions Status block Yes Single step Yes Number of breakpoints 20 Status/control • Status/control variable Yes Forcing • Forcing No Diagnostic buffer • present • Number of entries, max. - adjustable - preset Yes 3 200 Yes 120 5/88 SIMATIC WinAC RTX F 2010 Hardware requirements Hardware required Siemens ST 80 / ST PC · 2013 Configuration programming • Nesting levels • Programming language - LAD - FBD - STL - SCL - CFC - GRAPH - HiGraph® • Software libraries - Easy Motion Control Know-how protection • User program protection/password protection • Block encryption Open Development interfaces • CCX (Custom Code Extension) • CMI (Controller Management Interface) • SMX (Shared Memory Extension) - Inputs - Outputs Weight Weight, approx. 8 Yes Yes Yes Yes Yes Yes Yes Yes Yes No Yes; WinAC ODK V4.2 or higher Yes; WinAC ODK V4.2 or higher Yes; WinAC ODK V4.2 or higher 4 kbyte 4 kbyte 100 g; With packaging © Siemens AG 2013 PC-based Automation SIMATIC PC-based controllers SIMATIC WinAC RTX F ■ Ordering data Order No. ■ More information SIMATIC WinAC RTX F 2010 6ES7671-1RC08-0YA0 Add-ons for SIMATIC WinAC SIMATIC WinAC RTX F 2010 upgrade 6ES7671-1RC08-0YE0 PC-based Competence Center Cologne CP 5611 A2 communications processor 6GK1561-1AA01 Our add-ons supplement the WinAC RTX soft PLC by useful functions which have arisen in the context of projects. In this way, you can fully utilize the advantages of PC based Automation. PCI card (32 bit) for connection of a programming device or PC to PROFIBUS The applications are available in the form of function blocks and are easy to use without special programming knowledge. CP 5621 communications processor PCI Express x1 card (32 bit) for connection of a programming device or PC to PROFIBUS 6GK1562-1AA00 PCI Express x1 card (32 bit) CP 5621 and MPI cable, 5 m 6GK1562-1AM00 CP 5603 Microbox Package 6GK1560-3AU00 Contact: Comprising CP 5603 module and Microbox expansion rack CP 5613 A2 communications processor 6GK1561-3AA01 PCI card (32 bit; 3.3 V/5 V) for connection to PROFIBUS incl. DP-Base software with NCM PC; DP-RAM interface for DP master, incl. PG and FDL protocol; single license for 1 installation, runtime software, software and electronic manual on CD-ROM, Class A, for 32 bit Windows 2000 Professional/ Server, Windows XP Professional, German/English CP 5623 communications processor 6GK1161-6AA02 PCI Card (32 bit; 3.3/5 V universal key) with ASIC ERTEC 400 for connecting PCs to PROFINET IO with 4-port real-time switch (RJ45); incl. IO-Base software for PROFINET IO controller (RT operation) and NCM PC; single license for one installation, runtime software, software and electronic manual on CD-ROM, Class A, for 32 bit Windows XP Professional; German/English CP 1604 Microbox Package Siemens AG Competence Center Cologne E-mail: CCCologne@siemens.com Application Function WinAC serial driver Communication over serial interfaces WinAC PC IO driver Access to central I/O expansion PC IO including interrupt handling WinAC SQL Access to SQL databases WinAC TCP/IP driver Data exchange between WinAC and other communication partners over Windows interface using TCP/IP, UDP, or ISO-on-TCP WinAC OPC Client Access to various OPC servers WinAC Shutdown Controlled shutdown of WinAC and the PC system WinAC File I/O Reading and writing of DBs as a file on the PC system WinAC Command Calling batch commands from WinAC WinAC Access DB High-performance accesses to DBs, bit memories or I/O image WinAC SMX Cover Provides SMX functions, e.g. for Delphi or VB WinAC CMI Wrapper Easy program-controlled operation of WinAC 6GK1562-3AA00 PCI Express x1 card (32 bit) for connection to PROFIBUS incl. DP-Base software with NCM PC; DP-RAM interface for DP master or DP slave, incl. PG and FDL protocols; single license for 1 installation, runtime software, software and electronic manual on CD-ROM, Class A, for operating system support see SIMATIC NET software; German/English CP 1616 communications processor Detailed information and prices can be obtained from your Siemens contact or from: Brochures Information material is available for downloading in the Internet at: http://www.siemens.com/simatic/printmaterial 6GK1160-4AU00 Package for implementing the CP 1604 in the SIMATIC Microbox PC; comprising the CP 1604, connection board, power supply and expansion rack for Microbox PC; for use with Development Kit DK-16xx PN IO; NCM PC Siemens ST 80 / ST PC · 2013 5/89 5 © Siemens AG 2013 PC-based Automation SIMATIC PC-based controllers SIMATIC WinAC ODK ■ Overview ■ Technical specifications 6ES7806-1CC03-0BA0 SIMATIC WinAC ODK V4.2 Hardware requirements Hardware required Required memory on hard disk, min. 30 Mbyte Main memory, min. 512 Mbyte Processor Intel Pentium 800 MHz Operating systems Windows XP Yes; Professional, SP2 and SP3 Configuration Open Development interfaces • CCX (Custom Code Extension) • SIMATIC WinAC software PLCs support powerful interfaces which permit close meshing of the control task with PC-based applications. • WinAC ODK allows the user to develop applications or to integrate already existing applications into the control task. 5 New with WinAC ODK V4.2: • CCX interface: - New SFB 65003 for asynchronous execution of ODK applications - Expansion of data access functions - Creation of Windows DLL with C# and VB • SMX interface: - Access to the Shared Memory interface under IntervalZero RTX - Expansion of data access functions - Creation of Windows applications with C# and VB • Supports MS Visual Studio 2005 and 2008 (under Windows) PC with color monitor, keyboard, mouse or pointing device for Windows • CMI (Controller Management Interface) • SMX (Shared Memory Extension) Weight Weight, approx. ■ Ordering data SIMATIC WinAC ODK V4.2 Yes; WinAC RTX 2008 (V4.4) or higher; programming languages: Microsoft Visual C++ V6.0 SP5 or higher, .net 2003, 2005, 2008; Microsoft Visual Basic 2005, 2008; Microsoft Visual C# 2005, 2008 Yes; WinAC RTX 2005 SP2 (V4.3) or higher; programming languages: Microsoft Visual C++ V6.0 SP5 or higher, .net 2003, 2005, 2008; Microsoft Visual Basic V6.0 SP5 or higher, .net 2003, 2005, 2008; Microsoft Visual C# .net 2003, 2005, 2008 Yes; WinAC RTX 2008 (V4.4) or higher; programming languages: Microsoft Visual C++ V6.0 SP5 or higher, .net 2003, 2005, 2008; Microsoft Visual Basic 2005, 2008; Microsoft Visual C# 2005, 2008 200 g Order No. 6ES7806-1CC03-0BA0 for integration of C/C++ code in WinAC PLCs, executable under Windows XP SP2 or SP3; CD-ROM with electronic documentation Single license ■ More information Brochures Information material for downloading can be found in the Internet: http://www.siemens.com/simatic/printmaterial 5/90 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation Embedded Controller Embedded Controller ■ Overview SIMATIC IPC bundles The SIMATIC IPC bundles are ready-to-use, combined embedded PCs with the following SIMATIC software options: • SIMATIC WinAC RTX • SIMATIC WinAC RTX F • SIMATIC WinCC flexible or WinCC RT Advanced • Combinations with WinAC and WinCC SIMATIC IPC227D and IPC277D bundles SIMATIC IPC227D and SIMATIC IPC277D are also available with ready-to-use, pre-installed SIMATIC software: • SIMATIC WinCC RT Advanced • SIMATIC WinAC RTX • SIMATIC WinAC RTX F • Combinations of SIMATIC WinAC (F) and WinCC An embedded PC or embedded device is combined with automation software (e.g. software PLC, HMI system, etc.) and is ready-for-use. Windows Embedded Standard or Windows Embedded Compact is used as the operating system. PC-based Automation comprises: • Control • Technology • Visualization • Data processing • Communication • Fail-safe on a common embedded PC platform. S7-mEC SIMATIC S7-mEC is a modular controller in S7-300 design with powerful embedded PC technology. The embedded controller combines the advantages of the tried-and-tested modular S7 controller with PC technology in one new device. SIMATIC S7-mEC RTX is characterized by: • Maximum ruggedness without fan or hard disk • Modular expansion options, e.g. central expansion with S7-300 I/O or PC interfaces • Commissioning, as for S7-300, by automation specialists • SIMATIC WinAC RTX or alternatively WinAC RTX F preinstalled as a software PLC. The panels are available in 7", 9", 12", 15" and 19" TFT touch operation. With their compact structure, these SIMATIC IPCs are the ideal solution for simple control and HMI tasks on a single platform and also offer the openness of a PC-based system. SIMATIC IPC477C bundles As in the case of SIMATIC IPC427C, the SIMATIC HMI IPC477C can also be ordered with ready-to-use, pre-installed SIMATIC software: • SIMATIC WinCC flexible or WinCC RT Advanced • SIMATIC WinAC RTX • SIMATIC WinAC RTX F • Combinations of SIMATIC WinAC RTX (F) and WinCC The panels are available in 12", 15" and 19" front variants, optionally with touch or key functionality. With their compact structure, Panel PCs are the ideal solution for complex control and HMI tasks on a single platform and also offer the openness of a PC-based system. SIMATIC IPC477D bundles As in the case of SIMATIC IPC427D, the SIMATIC IPC477D can also be ordered with ready-to-use, pre-installed SIMATIC software: • SIMATIC WinCC RT Advanced • SIMATIC WinAC RTX • SIMATIC WinAC RTX F • Combinations of SIMATIC WinAC RTX (F) and WinCC The panels are available in 12" TFT Touch, 15" TFT Touch, 15" TFT Touch/Key, 19" TFT Touch and 22" TFT Touch front variants. With their compact structure, Panel PCs are the ideal solution for complex control and HMI tasks on a single platform and also offer the openness of a PC-based system. Siemens ST 80 / ST PC · 2013 5/91 5 © Siemens AG 2013 PC-based Automation Embedded Controller Embedded Controller ■ More information (continued) Decision aid for the use of embedded systems Customer benefits Modular Control PC-based Automation SIMATIC S7 S7 Modular Embedded Controller (S7-mEC) IPC227D, IPC277D bundles IPC427C/D bundles, HMI IPC477C/ IPC477D bundles on SIMATIC PC Ruggedness •• • • • • (depends on hardware configuration) Type of construction Modular Modular Compact Compact Depending on the type of construction Spare parts availability (beyond date of discontinuation) 10 years 5 years 5 years 5 years 5 years Design Performance Fast restart after power failure • - - - - Hard real-time •• •• •• •• •• Fast program processing • •• •• (depending on processor) •• (depending on processor) ••• (depending on processor) Safety Integrated • •• (option) •• (option) •• (option) •• ••/•• •/•• -/•• •/•• 4x7D: - / • • -/•• • • • • - I/O interfacing Central/distributed User know-how Preconfigured, turnkey Previous knowledge 5 PLC ••• •• • • • PC - • •• •• ••• HMI - o o o •• - • • • • Modularization with distributed intelligence (CBA) • • • • • Integration of PLC and HMI on one hardware platform - • • • • Openness Openness • Integration of C++ programs • Further processing of data using external programs via OPC on a hardware platform • Applies o Applies under certain conditions - Does not apply ■ More information Brochures Information material for downloading can be found in the Internet: http://www.siemens.com/simatic/printmaterial 5/92 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation Embedded Controller EC31 ■ Overview • Get off to a fast start in automation solutions with embedded PC platforms. - Ready-to-use SIMATIC WinAC RTX or WinAC RTX F preinstalled on EC31 - Prepared for use in a SIMATIC environment with PROFINET and Industrial Ethernet - Commissioning by specialist automation personnel as with the S7-300 - Configuring and programming with SIMATIC STEP 7 over Industrial Ethernet - Optional visualization • Modular expansion capability: Central expansion with - S7-300 I/O (SM modules of S7-300) - Expansion modules for additional PC interfaces, e.g. DVI-I, USB, Gigabit Ethernet networks and memory card slots, as well as PCI-104 • Rugged operation - Hard-disk-free operation based on flash disk and Windows Embedded Standard - Fan-free operation • Flexibility of a PC-based automation environment - Free memory space on flash disk can be used for other PC applications - Use of WinAC ODK with SIMATIC WinAC RTX and WinAC RTX F (read-only in safety-related program part) - Connection option for USB devices - Memory capacity expandable using multimedia card • Data retentivity for WinAC RTX and RTX F without uninterruptible power supply (UPS) ■ Technical specifications 6ES7677-1DD100BA0 6ES7677-1DD100BB0 6ES7677-1FD100FB0 6ES7677-1DD100BF0 6ES7677-1DD100BG0 6ES7677-1DD100BH0 SIMATIC S7-mEC, EC31 S7-mEC, EC31-RTX S7-mEC, EC31-RTX F S7-mEC, EC31HMI/RTX 128PT S7-mEC, EC31HMI/RTX 512PT S7-mEC, EC31HMI/RTX 2048PT General information Hardware product version 01 01 01 01 01 01 Firmware version V2.0 V2.0 V2.0 V2.0 V2.0 V2.0 SIMATIC S7 modular embedded controller SIMATIC S7 modular embedded controller SIMATIC S7 modular embedded controller SIMATIC S7 modular embedded controller SIMATIC S7 modular embedded controller SIMATIC S7 modular embedded controller Processor selection Intel Core Duo 1.2 GHz Intel Core Duo 1.2 GHz Intel Core Duo 1.2 GHz Intel Core Duo 1.2 GHz Intel Core Duo 1.2 GHz Intel Core Duo 1.2 GHz Main memory 1 GB RAM 1 GB RAM 1 GB RAM 1 GB RAM 1 GB RAM 1 GB RAM Operating systems Windows Embedded Standard 2009 Windows Embedded Standard 2009 Windows Embedded Standard 2009 Windows Embedded Standard 2009 Windows Embedded Standard 2009 Windows Embedded Standard 2009 SIMATIC WinAC RTX 2010 Yes SIMATIC WinAC RTX F 2010 Yes WinCC flexible RT 2008 SP2, incl. Sm@rtAccess, recipes, archives options SIMATIC WinAC RTX 2010 Yes WinCC flexible RT 2008 SP2, incl. Sm@rtAccess, recipes, archives options SIMATIC WinAC RTX 2010 Yes WinCC flexible RT 2008 SP2, incl. Sm@rtAccess, recipes, archives options SIMATIC WinAC RTX 2010 Yes 34 W 34 W 34 W 34 W 34 W PC configuration Computer platform Installed software • Visualization • Control • Communication Power losses Power loss, typ. 34 W Siemens ST 80 / ST PC · 2013 5/93 5 © Siemens AG 2013 PC-based Automation Embedded Controller EC31 ■ Technical specifications (continued) Memory Memory type Work memory • integrated 6ES7677-1DD100BA0 6ES7677-1DD100BB0 6ES7677-1FD100FB0 6ES7677-1DD100BF0 6ES7677-1DD100BG0 6ES7677-1DD100BH0 SIMATIC S7-mEC, EC31 S7-mEC, EC31-RTX S7-mEC, EC31-RTX F S7-mEC, EC31HMI/RTX 128PT S7-mEC, EC31HMI/RTX 512PT S7-mEC, EC31HMI/RTX 2048PT 256 KB non-volatile memory for retentive data 512 KB non-volatile memory for retentive data 512 KB non-volatile memory for retentive data 512 KB non-volatile memory for retentive data 512 KB non-volatile memory for retentive data 512 KB non-volatile memory for retentive data 1 Gbyte 1 Gbyte 1 Gbyte 1 Gbyte 1 Gbyte 1 Gbyte CPU processing times for bit operations, typ. 0.004 µs; typ. 0.004 µs; typ. 0.004 µs; typ. 0.004 µs; typ. 0.004 µs; typ. for fixed point arithmetic, typ. 0.003 µs; typ. 0.003 µs; typ. 0.003 µs; typ. 0.003 µs; typ. 0.003 µs; typ. for floating point arithmetic, typ. 0.004 µs; typ. 0.004 µs; typ. 0.004 µs; typ. 0.004 µs; typ. 0.004 µs; typ. Max. code size and max. data size: 4 MB each 64 kbyte Max. code size and max. data size: 4 MB each 64 kbyte Max. code size and max. data size: 4 MB each 64 kbyte Max. code size and max. data size: 4 MB each 64 kbyte Max. code size and max. data size: 4 MB each 64 kbyte Max. code size and max. data size: 4 MB each 64 kbyte Max. code size and max. data size: 4 MB each 64 kbyte Max. code size and max. data size: 4 MB each 64 kbyte Max. code size and max. data size: 4 MB each 64 kbyte Max. code size and max. data size: 4 MB each 64 kbyte Max. code size and max. data size: 4 MB each 64 kbyte Max. code size and max. data size: 4 MB each 64 kbyte Max. code size and max. data size: 4 MB each 64 kbyte Max. code size and max. data size: 4 MB each 64 kbyte Max. code size and max. data size: 4 MB each 64 kbyte • Number of synchronous error OBs 64 kbyte 2; OB 100, 102 7; OB 80, 82-85, 86, 88 2; OB 121, 122 64 kbyte 2; OB 100, 102 7; OB 80, 82-85, 86, 88 2; OB 121, 122 64 kbyte 2; OB 100, 102 7; OB 80, 82-85, 86, 88 2; OB 121, 122 64 kbyte 2; OB 100, 102 7; OB 80, 82-85, 86, 88 2; OB 121, 122 64 kbyte 2; OB 100, 102 7; OB 80, 82-85, 86, 88 2; OB 121, 122 Nesting depth • per priority class • additional within an error OB 24 24 24 24 24 24 24 24 24 24 2 048 2 048 2 048 2 048 2 048 Yes 0 2 047 8 Yes 0 2 047 8 Yes 0 2 047 8 Yes 0 2 047 8 Yes 0 2 047 8 Yes 0 999 Yes 0 999 Yes 0 999 Yes 0 999 Yes 0 999 Yes SFB Yes SFB Yes SFB Yes SFB Yes SFB CPU-blocks DB • Number, max. • Size, max. FB • Number, max. • Size, max. FC • Number, max. • Size, max. 5 OB • Size, max. • Number of startup OBs • Number of asynchronous error OBs Counters, timers and their retentivity S7 counter • Number • Retentivity - adjustable - lower limit - upper limit - preset • Counting range - adjustable - lower limit - upper limit IEC counter • present • Type 5/94 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation Embedded Controller EC31 ■ Technical specifications (continued) 6ES7677-1DD100BA0 6ES7677-1DD100BB0 6ES7677-1FD100FB0 6ES7677-1DD100BF0 6ES7677-1DD100BG0 6ES7677-1DD100BH0 SIMATIC S7-mEC, EC31 S7-mEC, EC31-RTX S7-mEC, EC31-RTX F S7-mEC, EC31HMI/RTX 128PT S7-mEC, EC31HMI/RTX 512PT S7-mEC, EC31HMI/RTX 2048PT 2 048 2 048 2 048 2 048 2 048 Yes 0 2 047 Yes 0 2 047 Yes 0 2 047 Yes 0 2 047 Yes 0 2 047 10 ms 9 990 s 10 ms 9 990 s 10 ms 9 990 s 10 ms 9 990 s 10 ms 9 990 s IEC timer • present • Type Yes SFB Yes SFB Yes SFB Yes SFB Yes SFB Data areas and their retentivity retentive data area, total 512 KB 512 KB 512 KB 512 KB 512 KB Flag • Number, max. • Retentivity preset • Number of clock memories 16 kbyte MB 0 to MB 15 8 16 kbyte MB 0 to MB 15 8 16 kbyte MB 0 to MB 15 8 16 kbyte MB 0 to MB 15 8 16 kbyte MB 0 to MB 15 8 16 kbyte 16 kbyte 16 kbyte 16 kbyte 16 kbyte 16 kbyte 16 kbyte 16 kbyte 16 kbyte 16 kbyte 8 kbyte 8 kbyte 8 kbyte 8 kbyte 8 kbyte 8 kbyte 8 kbyte 8 kbyte 8 kbyte 8 kbyte Process image • Inputs, adjustable • Outputs, adjustable • Inputs, default • Outputs, default 16 kbyte 16 kbyte 512 byte 512 byte 16 kbyte 16 kbyte 512 byte 512 byte 8 kbyte 8 kbyte 512 byte 512 byte 8 kbyte 8 kbyte 512 byte 512 byte 8 kbyte 8 kbyte 512 byte 512 byte Subprocess images • Number of subprocess images, max. 15 15 15 15 15 Digital channels • Inputs • Outputs 128 000 128 000 128 000 128 000 128 000 128 000 128 000 128 000 128 000 128 000 Analog channels • Inputs • Outputs 8 000 8 000 8 000 8 000 8 000 8 000 8 000 8 000 8 000 8 000 Time of day Clock • Hardware clock (real-time clock) Yes Yes; Resolution: 1 s Yes Yes Yes Clock synchronization • supported • to PC-CP, slave • on Ethernet via NTP Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes S7 times • Number • Retentivity - adjustable - lower limit - upper limit • Time range - lower limit - upper limit Address area I/O address area • Inputs • Outputs • of which, distributed - Inputs - Outputs 5 Interfaces Number of USB interfaces 2 2 2 2 2 serial interface 0 0 0 0 0 X1: 2 ports 10/100 Mbit/s (ERTEC-based) X2: 1 port 10/100 Mbit/s X1: 2 ports 10/100 Mbit/s (ERTEC-based) X2: 1 port 10/100 Mbit/s X1: 2 ports 10/100 Mbit/s (ERTEC-based) X2: 1 port 10/100 Mbit/s X1: 2 ports 10/100 Mbit/s (ERTEC-based) X2: 1 port 10/100 Mbit/s X1: 2 ports 10/100 Mbit/s (ERTEC-based) X2: 1 port 10/100 Mbit/s Industrial Ethernet • Industrial Ethernet interface X1: 2 ports 10/100 Mbit/s (ERTEC-based) X2: 1 port 10/100 Mbit/s Siemens ST 80 / ST PC · 2013 5/95 © Siemens AG 2013 PC-based Automation Embedded Controller EC31 ■ Technical specifications (continued) 6ES7677-1DD100BA0 6ES7677-1DD100BB0 6ES7677-1FD100FB0 6ES7677-1DD100BF0 6ES7677-1DD100BG0 6ES7677-1DD100BH0 SIMATIC S7-mEC, EC31 S7-mEC, EC31-RTX S7-mEC, EC31-RTX F S7-mEC, EC31HMI/RTX 128PT S7-mEC, EC31HMI/RTX 512PT S7-mEC, EC31HMI/RTX 2048PT 1st interface Type of interface PROFINET PROFINET PROFINET PROFINET PROFINET Physics 2x RJ45 2x RJ45 2x RJ45 2x RJ45 2x RJ45 Automatic detection of transmission speed Yes Yes Yes Yes Yes Autonegotiation Yes Yes Yes Yes Yes Autocrossing Yes Yes Yes Yes Yes Number of connection resources 32 32 32 32 32 No Yes Yes No Yes Yes No Yes Yes Functionality • MPI • DP master • DP slave • PROFINET IO Device • PROFINET IO Controller • PROFINET CBA • Point-to-point connection 5 PROFINET IO Controller • Number of connectable IO devices, max. • Max. number of connectable IO devices for RT - of which in line, max. • Number of IO devices with IRT and the option "high flexibility" - of which in line, max. • Number of IO Devices with IRT and the option "high performance", max. - of which in line, max. • IRT, supported • Prioritized startup supported - Number of IO Devices, max. • Activation/deactivation of IO Devices - Maximum number of IO devices that can be activated/deactivated at the same time. • IO Devices changing during operation (partner ports), supported - Max. number of IO devices per tool • Device replacement without swap medium • Send cycles • Updating times • Services - PG/OP communication - S7 routing - S7 communication - Isochronous mode • Address area - Inputs, max. - Outputs, max. - User data per address area, max. - User data consistency, max. 5/96 Siemens ST 80 / ST PC · 2013 No Yes Yes No No No No Yes Yes No 256 256 256 256 256 256 256 256 256 256 256 256 256 256 256 256 256 256 256 256 61 256 61 256 61 256 61 256 61 256 64 Yes Yes 32 Yes 8 64 Yes Yes 32 Yes 8 64 Yes Yes 32 Yes 8 64 Yes Yes 32 Yes 8 64 Yes Yes 32 Yes 8 Yes Yes Yes Yes Yes 8 8 8 8 8 Yes Yes Yes Yes Yes Adjustable: 250 µs, 500 µs and 1 ms 250 µs - 128 ms (with signal cycle 250 µs); 500 µs 256 ms (with signal cycle 500 µs); 1 ms - 512 ms (with signal cycle 1 ms) Adjustable: 250 µs, 500 µs and 1 ms 250 µs - 128 ms (with signal cycle 250 µs); 500 µs 256 ms (with signal cycle 500 µs); 1 ms - 512 ms (with signal cycle 1 ms) Adjustable: 250 µs, 500 µs and 1 ms 250 µs - 128 ms (with signal cycle 250 µs); 500 µs 256 ms (with signal cycle 500 µs); 1 ms - 512 ms (with signal cycle 1 ms) Adjustable: 250 µs, 500 µs and 1 ms 250 µs - 128 ms (with signal cycle 250 µs); 500 µs 256 ms (with signal cycle 500 µs); 1 ms - 512 ms (with signal cycle 1 ms) Adjustable: 250 µs, 500 µs and 1 ms 250 µs - 128 ms (with signal cycle 250 µs); 500 µs 256 ms (with signal cycle 500 µs); 1 ms - 512 ms (with signal cycle 1 ms) Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes 16 kbyte 16 kbyte 2 kbyte 256 byte 16 kbyte 16 kbyte 2 kbyte 256 byte 16 kbyte 16 kbyte 2 kbyte 256 byte 16 kbyte 16 kbyte 2 kbyte 256 byte 16 kbyte 16 kbyte 2 kbyte 256 byte © Siemens AG 2013 PC-based Automation Embedded Controller EC31 ■ Technical specifications (continued) 6ES7677-1DD100BA0 6ES7677-1DD100BB0 6ES7677-1FD100FB0 6ES7677-1DD100BF0 6ES7677-1DD100BG0 6ES7677-1DD100BH0 SIMATIC S7-mEC, EC31 S7-mEC, EC31-RTX S7-mEC, EC31-RTX F S7-mEC, EC31HMI/RTX 128PT S7-mEC, EC31HMI/RTX 512PT S7-mEC, EC31HMI/RTX 2048PT Yes 32 0, 20, 21, 23, 25, 80, 102, 135, 161, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535 Yes 32 0, 20, 21, 23, 25, 80, 102, 135, 161, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535 Yes 32 0, 20, 21, 23, 25, 80, 102, 135, 161, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535 Yes 32 0, 20, 21, 23, 25, 80, 102, 135, 161, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535 Yes 32 0, 20, 21, 23, 25, 80, 102, 135, 161, 8080, 34962, 34963, 34964, 65532, 65533, 65534, 65535 Yes; DCP Yes; DCP Yes; DCP Yes; DCP Yes; DCP Yes; DCP Yes; DCP Yes; DCP Yes; DCP Yes; DCP Yes; DCP Yes; DCP Yes; DCP Yes; DCP Yes; DCP Yes; LLDP, LLDP MIB, SNMP Yes; Standard MIB II, SNMP Yes; LLDP, LLDP MIB, SNMP Yes; Standard MIB II, SNMP Yes; LLDP, LLDP MIB, SNMP Yes; Standard MIB II, SNMP Yes; LLDP, LLDP MIB, SNMP Yes; Standard MIB II, SNMP Yes; LLDP, LLDP MIB, SNMP Yes; Standard MIB II, SNMP Integrated Ethernet interface Integrated Ethernet interface Integrated Ethernet interface Integrated Ethernet interface Integrated Ethernet interface Physics Ethernet RJ45 Ethernet RJ45 Ethernet RJ45 Ethernet RJ45 Ethernet RJ45 Automatic detection of transmission speed Yes Yes Yes Yes Yes Autonegotiation Yes Yes Yes Yes Yes Autocrossing No No No No No Number of connection resources 32 32 32 32 32 Functionality • PROFINET IO Controller • PROFINET IO Device • PROFINET CBA No No No No No No No No No No No No No No No Yes; DCP Yes; DCP Yes; DCP Yes; DCP Yes; DCP Yes; DCP Yes; DCP Yes; DCP Yes; DCP Yes; DCP Yes; DCP Yes; DCP Yes; DCP Yes; DCP Yes; DCP • Extended network diagnostics with Standard MIB II, supported Yes; LLDP, LLDP MIB, SNMP Yes; Standard MIB II, SNMP Yes; LLDP, LLDP MIB, SNMP Yes; Standard MIB II, SNMP Yes; LLDP, LLDP MIB, SNMP Yes; Standard MIB II, SNMP Yes; LLDP, LLDP MIB, SNMP Yes; Standard MIB II, SNMP Yes; LLDP, LLDP MIB, SNMP Yes; Standard MIB II, SNMP Communication functions PG/OP communication Yes Yes Yes Yes Yes Global data communication • supported No No No No No S7 basic communication • supported No No No No No S7 communication • supported • as server • as client Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Open IE communication • Open IE communication, supported • Number of connections, max. • Local port numbers used at the system end PROFINET functions • Detection of accessible nodes, supported • Assignment of the IP address, supported • Assignment of the device name, supported • Topology recognition, supported • Extended network diagnostics with Standard MIB II, supported 2nd interface Type of interface PROFINET functions • Detection of accessible nodes, supported • Assignment of the IP address, supported • Assignment of the device name, supported • Topology recognition, supported Siemens ST 80 / ST PC · 2013 5 5/97 © Siemens AG 2013 PC-based Automation Embedded Controller EC31 ■ Technical specifications (continued) 6ES7677-1DD100BA0 6ES7677-1DD100BB0 6ES7677-1FD100FB0 6ES7677-1DD100BF0 6ES7677-1DD100BG0 6ES7677-1DD100BH0 SIMATIC S7-mEC, EC31 S7-mEC, EC31-RTX S7-mEC, EC31-RTX F S7-mEC, EC31HMI/RTX 128PT S7-mEC, EC31HMI/RTX 512PT S7-mEC, EC31HMI/RTX 2048PT Yes; Via integrated PROFINET interface (X1) and loadable FBs 32 32 kbyte Yes; Via integrated PROFINET interface (X1) and loadable FBs 32 32 kbyte Yes; Via integrated PROFINET interface (X1) and loadable FBs 32 1 472 byte Yes; Via integrated PROFINET interface (X1) and loadable FBs 32 32 kbyte Yes; via integrated PROFINET interface and loadable FBs 32 32 kbyte Yes; Via integrated PROFINET interface (X1) and loadable FBs 32 1 472 byte Yes; Via integrated PROFINET interface (X1) and loadable FBs 32 32 kbyte Yes; Via integrated PROFINET interface (X1) and loadable FBs 32 32 kbyte Yes; Via integrated PROFINET interface (X1) and loadable FBs 32 1 472 byte Yes; Via integrated PROFINET interface (X1) and loadable FBs 32 32 kbyte Yes; Via integrated PROFINET interface (X1) and loadable FBs 32 32 kbyte Yes; Via integrated PROFINET interface (X1) and loadable FBs 32 1 472 byte Yes; Via integrated PROFINET interface (X1) and loadable FBs 32 32 kbyte Yes; Via integrated PROFINET interface (X1) and loadable FBs 32 32 kbyte Yes; Via integrated PROFINET interface (X1) and loadable FBs 32 1 472 byte 62; The alarm functions cannot currently be used for central bus modules 62; The alarm functions cannot currently be used for central bus modules 62; The alarm functions cannot currently be used for central bus modules 62; The alarm functions cannot currently be used for central bus modules 62; The alarm functions cannot currently be used for central bus modules Process diagnostic messages Yes; Alarm_S Yes; Alarm_S Yes; Alarm_S Yes; Alarm_S Yes; Alarm_S Test commissioning functions Status/control • Status/control variable Yes Yes Yes Yes Yes Forcing • Forcing No No No No No Diagnostic buffer • present Yes Yes Yes Yes Yes 0 °C 50 °C 0 °C 50 °C 0 °C 50 °C 0 °C 50 °C 0 °C 50 °C Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Open IE communication • TCP/IP - Number of connections, max. - Data length, max. • ISO-on-TCP (RFC1006) - Number of connections, max. - Data length, max. • UDP - Number of connections, max. - Data length, max. S7 message functions Number of login stations for message functions, max. 5 Ambient conditions Operating temperature • Min. • max. 0 °C 50 °C Configuration programming • Programming language - LAD - FBD - STL - SCL - CFC - GRAPH - HiGraph® Dimensions Width 160 mm 160 mm 160 mm 160 mm 160 mm 160 mm Height 125 mm 125 mm 125 mm 125 mm 125 mm 125 mm Depth 115 mm 115 mm 115 mm 115 mm 115 mm 115 mm Weight Weight, approx. 1.5 kg 1.5 kg 1.5 kg 1.5 kg 1.5 kg 1.5 kg 5/98 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation Embedded Controller EC31 ■ Ordering data Order No. SIMATIC S7-modular Embedded Controller EC31 EM PCI-104 expansion module 6ES7677-1DD10-0BA0 Intel CoreDuo 1.2 GHz processor Memory configuration: 1 GB RAM, 4 GB Flash Disk; interfaces: 1 Industrial Ethernet port, 2 PROFINET ports, 2 USB ports, 1 slot for multimedia card; Software: Windows Embedded Standard preinstalled, Software Development Kit (SDK) for creating C/C++ applications with accesses to central I/O modules EC31-RTX Order No. Accessories 6ES7677-1DD60-1AA0 For fitting up to 3 additional PCI-104 cards EM PC expansion module 6ES7677-1DD50-2AA0 Additional connection options: 2 USB interfaces, 1 Gigabit Ethernet interface, 1 serial interface, 1 slot for CF card, 1 slot for SD card/Micro Memory Card 6ES7677-1DD10-0BB0 Intel CoreDuo 1.2 GHz processor Memory configuration: 1 GB RAM, 4 GB Flash Disk; interfaces: 1 Industrial Ethernet port, 2 PROFINET ports, 2 USB ports, 1 slot for multimedia card; Software: Windows Embedded Standard and WinAC RTX 2010 preinstalled EC31-RTX F 6ES7677-1FD10-0FB0 Intel CoreDuo 1.2 GHz processor Memory configuration: 1 GB RAM, 4 GB Flash Disk; interfaces: 1 Industrial Ethernet port, 2 PROFINET ports, 2 USB ports, 1 slot for multimedia card; Software: Windows Embedded Standard and WinAC RTX F 2010 preinstalled 5 EC31-HMI/RTX Intel CoreDuo 1.2 GHz processor Memory configuration: 1 GB RAM, 4 GB Flash Disk; interfaces: 1 Industrial Ethernet port, 2 PROFINET ports, 2 USB ports, 1 slot for multimedia card; Software: Windows Embedded Standard, WinAC RTX 2010, SIMATIC SOFTNET-S7/V7.0 Lean preinstalled • With WinCC flexible 2008 RT 128 PT • With WinCC flexible 2008 RT 512 PT • With WinCC flexible 2008 RT 2048 PT 6ES7677-1DD10-0BF0 6ES7677-1DD10-0BG0 6ES7677-1DD10-0BH0 Siemens ST 80 / ST PC · 2013 5/99 © Siemens AG 2013 PC-based Automation Embedded Controller Expansion modules ■ Overview ■ Technical specifications 6ES76771DD60-1AA0 6ES76771DD50-2AA0 EM PCI-104 EM PC General information Hardware product version 01 01 Input current from expansion bus 100 mA 580 mA 2.4 W; Without inserted PCI-104 cards 9W Power losses Power loss, typ. 14 W Power loss, max. Interfaces Number of USB interfaces 0 2 serial interface 0 1x V.24 (RS232) Industrial Ethernet • Industrial Ethernet interface • Expansion modules for SIMATIC S7-modular Embedded Controller EC31 - EM PCI-104 for additionally accommodating up to 3 PCI-104 cards - EM PC with additional PC interfaces and slots for memory media Ambient conditions Operating temperature • Min. • max. 0 °C 50 °C 0 °C 50 °C 120 mm; Without bus connector ExtensionBus 80 mm; Without bus connector Extension-Bus Height 125 mm; Without external voltage connecting terminal 125 mm Depth 115 mm 115 mm Weight Weight, approx. 0.5 kg 0.4 kg Dimensions Width 5 Onboard, 10/ 100/1000 Mbit, RJ45 ■ Ordering data EM PCI-104 expansion module Order No. 6ES7677-1DD60-1AA0 For fitting up to 3 additional PCI-104 cards EM PC expansion module Additional connection options: 1 DVI-I interface, 2 USB interfaces, 1 Gigabit Ethernet interface, 1 serial interface, 1 slot for CF card, 1 slot for SD card/Micro Memory Card 5/100 Siemens ST 80 / ST PC · 2013 6ES7677-1DD50-2AA0 © Siemens AG 2013 PC-based Automation Embedded bundles/Software packages Embedded bundles/Software packages ■ Overview The Embedded Bundles for PC-based Automation are based on rugged, fan-free SIMATIC IPCs. They are pre-installed, configured, and ready-to-use with the SIMATIC WinAC RTX (F) software controller and/or the SIMATIC WinCC/WinCC flexible visualization software. ■ More information You can find more information on the Internet at: http://www.automation.siemens.com/mcms/pc-basedautomation/en/embedded-bundles Software packages with WinCC or WinAC together with the corresponding SIMATIC IPC. The following are available: • SIMATIC IPC packages with WinCC flexible • SIMATIC IPC packages with WinCC RT Advanced (TIA Portal) • SIMATIC IPC Packages with WinCC • SIMATIC IPC packages with WinCC RT Professional (TIA Portal) • SIMATIC IPC packages with WinAC RTX (F) A Software Package can only be supplied if the same number of SIMATIC industrial PCs is ordered together with the software. It cannot be ordered subsequently. 5 Siemens ST 80 / ST PC · 2013 5/101 © Siemens AG 2013 PC-based Automation Embedded bundles/Software packages SIMATIC IPC227D bundles ■ Overview • A quick start in automation solutions with embedded PC platforms - SIMATIC WinAC RTX or SIMATIC WinAC RTX F preinstalled on SIMATIC IPC227D and ready for use - PROFINET RT and Industrial Ethernet pre-configured for use in a SIMATIC environment - Optional WinCC RT Advanced for visualization tasks in parallel with SIMATIC WinAC RTX - Configuration and programming with SIMATIC STEP 7 via Industrial Ethernet or PROFINET • Safety requirements up to SIL 3 in accordance with IEC 61508/62061 or EN ISO 13849-1 up to PL e can be implemented with WinAC RTX F. • Rugged operation - Hard-disk-free operation with CompactFlash card (CF card) or solid-state drive and Windows Embedded Standard 2009 or Windows Embedded Standard 7, 32-bit - Fan-free operation - 128 KB of retentive data for WinAC RTX, also without uninterruptible power supply (UPS) • Flexibility of a PC-based automation environment - Use of WinAC ODK with SIMATIC WinAC RTX or SIMATIC WinAC RTX F (read-only for fail-safe program section) - Connection option for USB devices, flat panel monitor or screen - PCIe cards can be plugged in ■ Technical specifications See "PC-based Automation -> Box PC -> SIMATIC IPC227D". ■ Ordering data For Selection and ordering data see SIMATIC Box PC -> SIMATIC IPC227D 5 ■ More information Delivery Production and delivery of the devices will typically be completed within 15 business days after receipt of order. The hardware and mass memory with the complete, pre-installed, ready-to-use software are supplied fully assembled. 5/102 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation Embedded bundles/Software packages SIMATIC IPC427D bundles ■ Overview SIMATIC IPC427D (Microbox PC): The powerful embedded IPC – maintenance-free with versatile configuration Ready-to-run, complete solutions (software is already installed and preconfigured) for visualization and automation in connection with WinCC RT Advanced and/or WinAC RTX. • Ultra-compact • Maintenance-free • Third generation Intel Core i technology • Current product versions of the pre-installed software: - SIMATIC WinCC RT Advanced V12 - SIMATIC WinAC RTX 2010 - SIMATIC Net V8.x ■ Technical specifications See "PC-based Automation -> Box PC -> SIMATIC IPC427D" ■ Ordering data For selection and ordering data, see "SIMATIC Box PC -> SIMATIC IPC427D" ■ More information Delivery Production and delivery of the devices will typically be completed within 13 business days after receipt of order. The hardware and mass memory with the complete, pre-installed, ready-to-use software are supplied fully assembled. Commissioning Before the control or visualization application is complete, simply perform the following steps: • Optional: Installation and setup of additional software on the device • Optional: Installation and setup of other software on the device • Transfer of the engineering projects from STEP 7 or WinCC Advanced • Transfer of the supplied license keys for SIMATIC software • Backup of the installed software and protection of the flashbased mass memory by switching on the Enhance Write filter 5 Siemens ST 80 / ST PC · 2013 5/103 © Siemens AG 2013 PC-based Automation Embedded bundles/Software packages SIMATIC IPC427C bundles ■ Overview Embedded PC platform with extremely high industrial compatibility for demanding tasks in the field of PC-based automation • Rugged operation - Operation without a hard disk, based on CompactFlash card (CF Card) or solid-state drive and Windows Embedded Standard - Fan-free operation - 128 KB of retentive data for WinAC RTX, also without uninterruptible power supply (UPS) • Flexibility of a PC-based automation environment - Free memory space on CF Card can be used for other PC applications - Use of WinAC ODK with SIMATIC WinAC RTX or SIMATIC WinAC RTX F (read-only for fail-safe program section) - Connection option for USB devices, flat panel monitor or screen - PCI 104 cards can be plugged in • High-performance service concept - Replacement parts for preferred types available ex stock • Safety requirements up to SIL 3 in accordance with IEC 61508/62061 or EN ISO 13849-1 up to PL e can be implemented with WinAC RTX F. • Cost-effective versions with PROFINET, based on the standard Ethernet interface • Current product versions of the pre-installed software: - SIMATIC WinAC RTX 2010 or SIMATIC WinAC RTX F 2010 - SIMATIC WinCC flexible 2008 or WinCC RT Advanced - and the combinations of the software packages above - SIMATIC NET Edition 2008 or V8.1 (depending on operating system), as well as - SIMATIC WInCC V7.0 SP2 or WinCC RT Professional as a client / single station 5 5/104 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation Embedded bundles/Software packages SIMATIC IPC427C bundles ■ Ordering data Order No. Order No. SIMATIC IPC427C bundles HMI bundles with WinCC flexible 2008 or WinCC RT Advanced V11 bundles HMI/RTX bundles combining HMI and RTX SIMATIC IPC427C with pre-installed software Processor • Celeron M, 1.2 GHz, 2x PROFINET (IE) 1) • Celeron M, 1.2 GHz, 2x PROFINET (IE), 1x PROFIBUS 1) • Core2 Solo, 1.2 GHz, 2x PROFINET (IE) 1) • Core2 Solo, 1.2 GHz, 2x PROFINET (IE), 1x PROFIBUS 1) • Core2 Solo, 1.2 GHz, 1x PROFINET (IE), PROFINET (RT/IRT) 3 ports • Core2 Duo, 1.2 GHz, 2x PROFINET (IE) 1) • Core2 Duo, 1.2 GHz, • 2x PROFINET (IE), 1x PROFIBUS 1) • Core2 Duo, 1.2 GHz, 1x PROFINET (IE), PROFINET (RT/IRT) 3 ports Main memory • 1 GB RAM • 2 GB RAM 1) • 4 GB RAM Operating system • Windows Embedded Standard 2009 (WES2009) 1) • Windows Embedded Standard 7 (WES7) 2) Mass storage, internal • None (can only be ordered with externally accessible mass storage) 1) • 250 GB HDD SATA, only additionally with externally accessible CF • 50 GB solid-state drive (high-endurance), operating system and software pre-installed • 80 GB solid-state drive (standard SATA), operating system and software pre-installed • 4 GB internal CompactFlash, operating system and software pre-installed 1) • 8 GB internal CompactFlash, operating system and software pre-installed 1) • 16 GB internal CompactFlash, operating system and software pre-installed 1) 6ES7675-1D 7 7 7 - 7 7 7 7 SIMATIC IPC427C with pre-installed software (continued) RTX bundles with SIMATIC WinAC RTX (F) 2010 6ES7675-1D 7 7 7 - 7 7 7 7 A B Externally accessible mass storage • None (can only be ordered with internal mass storage) 1) • 4 GB CompactFlash, operating system and software pre-installed 1) • 8 GB CompactFlash, operating system and software pre-installed 1) • 16 GB internal CompactFlash, operating system and software pre-installed 1) Software configurations 1) • WinAC RTX • HMI RT 128 PT • HMI RT 512 PT • HMI RT 2048 PT • HMI RT 4096 PT • WinAC RTX, HMI RT 128 PT • WinAC RTX, HMI RT 512 PT • WinAC RTX, HMI RT 2048 PT • WinAC RTX, HMI RT 4096 PT • WinAC RTX F • WinAC RTX F, HMI RT 128 PT • WinAC RTX F, HMI RT 512 PT • WinAC RTX F, HMI RT 2048 PT • WinAC RTX F, HMI RT 4096 PT E F G J K L 2 3 4 • HMI RT: WinCC flexible 2008 3) or w/o HMI software • HMI RT: WinCC Advanced V11 SP2 (TIA Portal), only with WES7 and 2GB RAM 0 A D E F B C D E F K L M N P R S T U 0 1 5 1 0 1 2 3 6 7 8 1) Replacement hardware units available in exchange 2) Only together from 2 GB main memory 3) WinCC flexible 2008 SP2 with WES2009 and WinCC flexible 2008 SP3 with WES7 Siemens ST 80 / ST PC · 2013 5/105 © Siemens AG 2013 PC-based Automation Embedded bundles/Software packages SIMATIC IPC427C bundles ■ Ordering data Order No. In-stock models Replacement hardware units available in exchange SIMATIC IPC427C bundle with WinAC RTX 2010 • Core2 Solo processor, 1.2 GHz, 2x PROFINET (IE), 1x PROFIBUS, 2 GB RAM, 4 GB CompactFlash • Core2 Duo processor, 1.2 GHz, 2x PROFINET (IE), 1x PROFIBUS, 2 GB RAM, 4 GB CompactFlash • Core2 Duo processor, 1.2 GHz, 2x PROFINET (IE), 1x PROFIBUS, 2 GB RAM, 8 GB CompactFlash SIMATIC IPC427C bundle with WinAC RTX 2010 and WinCC flexible 2008 512 PT • Core2 Duo processor, 1.2 GHz, 2x PROFINET (IE), 1x PROFIBUS, 2 GB RAM, 4 GB CompactFlash ("Built to order" with max. delivery time of 14 working days; only repairs are possible for hardware) 6ES7675-1DF30-0DB0 6ES7675-1DK30-0DB0 6ES7675-1DK30-0EP0 6ES7675-1DK30-0DL0 Bundles with WinCC IPC427C with WinCC RT, V7.0 SP2, incl. Update 1 Fan-free, 4 x USB 2.0 (500 mA), 1 x COM (RS 232), 24 V DC power supply with On/Off switch, 2 x PROFINET (IE), Windows Embedded Standard 2009 pre-installed, SIMATIC WinCC V7.0 SP2 incl. Update1 Runtime pre-installed 5 Client and stand-alone station configurations • Core2 Solo processor 1.2 GHz, 8 GB CF card, runtime license 128 PT1) • Core2 Solo processor 1.2 GHz, PROFIBUS DP, 2 GB SDRAM-DDR3, 8 GB CF card, runtime license 128 PT1) Stand-alone station configurations Core2 Duo processor 1.2 GHz, PROFIBUS DP, 4 GB SDRAM-DDR3 • 8 GB CF card, runtime license 128 PT1) • 50 GB SSD (High Endurance), runtime license 128 PT1) • 8 GB CF card, runtime license 2048 PT1) • 50 GB SSD (High Endurance), runtime license 2048 PT1) 1) 6ES7675-1DA20-6AX0 6ES7675-1DE30-7AX0 Client configurations • Celeron M processor 1.2 GHz, 2 GB SDRAM DDR3, 8 GB CF card, runtime license 128 PT 1) Stand-alone station configurations Core2 Duo processor 1.2 GHz, PROFIBUS DP, 4 GB SDRAM-DDR3 • 8 GB CF card, runtime license 128 PT1) • 50 GB SSD (High Endurance), runtime license 128 PT1) • 8 GB CF card, runtime license 2048 PT1) • 50 GB SSD (High Endurance), runtime license 2048 PT1) 6ES7675-1DA31-7AY0 6ES7675-1DE31-7AY0 6ES7675-1DF31-7AY0 6ES7675-1DK41-7AY0 6ES7675-1DK41-2AY0 6ES7675-1DK41-7AV0 6ES7675-1DK41-2AV0 Accessories 6ES7675-1DF30-7AX0 CP 5603 Microbox Package Package for using the PROFIBUS CP 5603 in Microbox PCs; comprising a CP 5603 module and a Microbox expansion rack 6GK1560-3AU00 6ES7675-1DK40-.A.0 6GK1160-4AU00 6ES7675-1DK40-7AW0 CP 1604 Microbox Package Package for the use of the PROFINET CP 1604 in Microbox PCs; consisting of CP 1604 card, connection board, power supply and Microbox PC expansion frame; used via development kit DK-16xx PN IO; NCM P Portrait assembly kit Interfaces to the front 6ES7648-1AA20-0YB0 6ES7675-1DK40-2AW0 Expansion components From page 5/153 6ES7675-1DK40-7AX0 6ES7675-1DK40-2AX0 Number of process tags (PT) can be increased by means of PowerPacks. 5/106 IPC427C with WinCC RT Professional, V11 SP2 Fan-free, 4 x USB 2.0 (500 mA), 1 x COM (RS 232), 24 V DC power supply with On/Off switch, 2 x PROFINET (IE), Windows Embedded Standard 7 SP1 pre-installed, SIMATIC WinCC Runtime Professional V11 SP2 pre-installed Client and stand-alone station configurations • Core2 Solo processor 1.2 GHz, 2 GB SDRAM DDR3, 8 GB CF card, runtime license 128 PT 1) • Core2 Solo processor 1.2 GHz, PROFIBUS DP, 2 GB SDRAM DDR3, 8 GB CF card, runtime license 128 PT 1) ("Built to order" with max. delivery time of 14 working days; only repairs are possible for hardware) Client configurations Processor Celeron M 1.2 GHz, 1 GB SDRAM-DDR3, 4 GB CF Card, runtime license 128 PT Order No. Bundles with WinCC RT Professional (TIA Portal) Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation Embedded bundles/Software packages SIMATIC IPC427C bundles ■ More information Delivery Replacement units Production and delivery of the devices will typically be completed within 13 business days after receipt of order. The hardware and mass memory with the complete, pre-installed, ready-to-use software are supplied fully assembled. For the preferred versions, repaired replacement devices are available extremely quickly ex stock. Preferred versions offer the following options: • All processor versions with PROFINET(IE) or PROFIBUS option • 2 GB RAM • Exclusively for replaceable CompactFlash memory (supplied without mass memory) • All software configurations Commissioning Before the control or visualization application is complete, simply perform the following steps: • Optional: Install and setup additional hardware on the device (e.g. an additional SIMATIC CP 5603 PROFIBUS interface) • Optional: Installation and setup of other software on the device • Transfer of the engineering projects from STEP 7 and/or WinCC flexible • Transfer of the supplied license keys for SIMATIC software • Backup of the installed software and protection of the flashbased mass memory by switching on the Enhance Write filter 5 Siemens ST 80 / ST PC · 2013 5/107 © Siemens AG 2013 PC-based Automation Embedded bundles/Software packages SIMATIC IPC277D bundles ■ Overview ■ Technical specifications See "PC-based Automation -> Panel PC -> SIMATIC IPC277D" ■ Ordering data For selection and ordering data see SIMATIC Panel PC -> SIMATIC IPC277D ■ More information Delivery Production and delivery of the devices will typically be completed within 13 business days after receipt of order. The hardware and mass memory with the complete, pre-installed, ready-to-use software are supplied fully assembled. 5 SIMATIC IPC277D for implementing simple visualization and control tasks • High degree of flexibility when selecting rugged widescreen fronts from 7" to 19" for more freely configurable display area • High resolution, large viewing angle and up to 100% dimmable backlighting for brilliant display with optimized power consumption • Absolutely maintenance-free due to the use of CompactFlash and SSD as mass storage and fanless operation up to 50 °C ambient temperature • Maximum industrial functionality due to non-volatile retentive memory for battery-free operation • Ready-to-run embedded bundles with visualization or/and control software The following front installation versions are available: • 7" Touch • 9" Touch • 12" Touch • 15" Touch with front USB interface • 19" Touch with front USB interface • All fronts in widescreen design 5/108 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation Embedded bundles/Software packages SIMATIC IPC477D bundles ■ Overview ■ Integration Integrated interfaces: • Ethernet The integral PROFINET interfaces (10/100/1000 Mbit/s) can be used for IT communication and for data exchange with programmable controllers such as SIMATIC S7 (with software packages "SOFTNET S7 Basis"). • PROFIBUS onboard (option) The isolated PROFIBUS interface (12 Mbit/s) can be used for connecting distributed field devices or for coupling to SIMATIC S7 (with software packages "SOFTNET for PROFIBUS"). • Other interfaces 5 USB (Universal Serial Bus) interfaces and up to two serial interfaces are available for connecting additional I/O devices. ■ Technical specifications See "PC-based Automation -> Panel PC -> SIMATIC IPC477D" SIMATIC IPC477D: The powerful embedded Panel PC – maintenance-free with versatile configuration Ready-to-run, complete solutions (software is already installed and preconfigured) for visualization and automation in connection with WinCC RT Advanced and/or WinAC RTX. • Embedded PC platform with extremely high industrial compatibility for demanding tasks in the field of PC-based automation • Maintenance-free (no rotating components such as fan and hard disk) • Rugged construction: the PC is resistant to even the harshest mechanical stress and is extremely reliable in operation • Compact design • Battery-independent retentive memory onboard • High investment protection • Fast integration capability • Safety requirements up to SIL 3 in accordance with IEC 61508/62061 or EN ISO 13849-1 up to PL e can be implemented with WinAC RTX F ■ Ordering data For selection and ordering data, see SIMATIC Panel PC -> SIMATIC IPC477D 5 The following front versions are available: • Built-in versions - 12" TFT Touch - 15" TFT Touch - 19" TFT Touch - 22" TFT Touch - 15" TFT Touch/Key • Current product versions of the pre-installed SIMATIC software: - SIMATIC WinCC RT Advanced V12 - SIMATIC WinAC RTX 2010 or SIMATIC WinAC RTX F 2010 - SIMATIC NET V8.2 (including SIMATIC SOFTNET S7 Basis license) - and the combinations of the software packageslisted above Siemens ST 80 / ST PC · 2013 5/109 © Siemens AG 2013 PC-based Automation Embedded bundles/Software packages SIMATIC HMI IPC477C bundles ■ Overview Embedded PC platform with extremely high industrial compatibility for demanding tasks in the field of PC-based automation. • Rugged operation - Operation without a hard disk, based on CompactFlash card (CF Card) or solid-state drive and Windows Embedded Standard - Fan-free operation - 128 KB of retentive data for WinAC RTX, also without uninterruptible power supply (UPS) • Flexibility of a PC-based automation environment - Free memory space on CF Card can be used for other PC applications - Use of WinAC ODK with SIMATIC WinAC RTX or SIMATIC WinAC RTX F (read-only for fail-safe program section) - Connection option for USB devices, flat panel monitor or screen • High-performance service concept - Replacement parts for preferred types available ex stock • Safety requirements up to SIL 3 in accordance with IEC 61508/62061 or EN ISO 13849-1 up to PL e can be implemented with WinAC RTX F. • Cost-effective versions with PROFINET, based on the standard Ethernet interface • Product versions of the pre-installed software: - SIMATIC WinAC RTX 2010 or SIMATIC WinAC RTX F 2010 - SIMATIC WinCC flexible 2008 or WinCC RT Advanced - and the combinations of the software packages above - SIMATIC NET Edition 2008 or V8.x (depending on operating system) as well as - SIMATIC WInCC V7.0 SP2 or WinCC RT Professional as a client / single station The following display versions are available: • Built-in versions - 12" and 15" TFT Touch - 12" and 15" TFT Key - 19" Touch • Support arm versions - PRO 15" and 19" Touch Fully-enclosed device to IP65 degree of protection for mounting on a support arm/stand. 5 5/110 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation Embedded bundles/Software packages SIMATIC HMI IPC477C bundles ■ Ordering data Order No. SIMATIC HMI IPC477C bundles HMI bundles with WinCC flexible 2008 or WinCC RT Advanced bundles HMI/RTX bundles combining HMI and RTX ("Built to order" version, max. delivery time of 15 working days and with identified repair, if not preferred type) 6AV7883- 7 A 7 7 7 - 7 7 7 7 Embedded and fan-free with fully enclosed IP65 enclosure 4 x USB (500 mA), 24 V DC power supply with On/Off switch SIMATIC HMI IPC477C 6AV7884- 7 A 7 7 7 - 7 7 7 7 SIMATIC HMI IPC477C (continued) RTX bundles with SIMATIC WinAC RTX (F) 2010 SIMATIC HMI IPC477C PRO Order No. 6AV7884- 7 A 7 7 7 - 7 7 7 7 Fan-free 5 x USB 2.0 (500 mA), one of which on the front 1 x COM (RS232) 24 V DC power supply with On/Off switch Front panels • 12" TFT Touch 1) • 12" TFT Key • 15" TFT Touch 1) • 15" TFT Key • 19" TFT Touch 1) • 15" TFT Touch (IP65 enclosure; PRO) • 19" TFT Touch (IP65 enclosure; PRO) 0 1 2 3 5 6 7 1) Preferred versions with repaired replacement device from warehouse 2) Only together from 2 GB main memory 3) Only with IPC477C Processors and fieldbus • Celeron M 1.2 GHz, 2 x PROFINET (IE) 1) • Celeron M 1.2 GHz, 2 x PROFINET (IE), 1 x PROFIBUS DP 12 1) • Core2 Solo 1.2 GHz, 2 x PROFINET (IE) 1) • Core2 Solo 1.2 GHz, 2 x PROFINET (IE), 1 x PROFIBUS DP 12 1) • Core2 Solo 1.2 GHz, 1 x PROFINET (IE), 1 x PROFINET (3 ports) 1) • Core2 Duo 1.2 GHz, 2 x PROFINET (IE) 1) • Core2 Duo 1.2 GHz, 2 x PROFINET (IE), 1 x PROFIBUS DP 12 1) • Core2 Duo 1.2 GHz, 1 x PROFINET (IE), 1 x PROFINET (3 ports) 1) A B D E F G H J Main memory (DDR3 RAM), 1 database • 1 GB • 2 GB 1) • 4 GB 1 2 3 Second mass storage (installed, CF replaceable) • None 1) • CompactFlash 2 GB (only with Windows Embedded Standard 2009) 1) • CompactFlash 4 GB 1) • CompactFlash 8 GB 1) • CompactFlash 16 GB 1) • 50 GB SSD (High Endurance) • 80 GB SSD (Standard) 3) 0 2 3 4 5 6 7 Siemens ST 80 / ST PC · 2013 5 5/111 © Siemens AG 2013 PC-based Automation Embedded bundles/Software packages SIMATIC HMI IPC477C bundles ■ Ordering data SIMATIC HMI IPC477C (continued) Order No. Mass storage (installed, operating system pre-installed, optionally with SIMATIC software) • CompactFlash 2 GB 1) • CompactFlash 4 GB 1) • CompactFlash 8 GB 1) • CompactFlash 16 GB 1) • 50 GB SSD (High Endurance) • 80 GB SSD (Standard) 3) Operating system • Windows Embedded Standard 2009, pre-installed 1) • Windows Embedded Standard 7 SP1, pre-installed 2) 5 Order No. 6AV7884- 7 A 7 7 7 - 7 7 7 7 Software packages, only with CF 4 GB or higher 1) • with operating system and RTX pre-installed and configured • with operating system and HMI (incl. archives/recipes) pre-installed and configured - Number of tags 128 PT - Number of tags 512 PT - Number of tags 2048 PT - Number of tags 4096 PT • with operating system and HMI/RTX (incl. archives/recipes) pre-installed and configured - Number of tags 128 PT - Number of tags 512 PT - Number of tags 2048 PT - Number of tags 4096 PT • with operating system and RTX F pre-installed and configured • with operating system and HMI/RTX F (incl. archives/recipes) pre-installed and configured - Number of tags 128 PT - Number of tags 512 PT - Number of tags 2048 PT - Number of tags 4096 PT Bundles with WinCC RT Professional (TIA Portal) ("Built to order" with max. delivery time of 14 working days; only repairs are possible for hardware) SIMATIC HMI IPC477C 2 3 4 5 6 7 BA E A SIMATIC HMI IPC477C PRO C D E F Front panel • 15" TFT Touch • 19" TFT Touch • 15" TFT Touch PRO • 19" TFT Touch PRO K L M N P 6AV78846AV78846AV78836AV7883- 2 5 6 7 Client configurations Celeron M processor 1.2 GHz, 1 GB DDR3 RAM, 4 GB CF card, runtime license 128 PT A 2 4 Y Core2 Solo processor 1.2 GHz, 2 GB SDRAM-DDR3, 8 GB CF card, runtime license 128 PT D 2 4 Y Core2 Solo processor 1.2 GHz, PROFIBUS DP, 2 GB SDRAM-DDR3, 8 GB CF card, runtime license 128 PT E 2 4 Y Client and stand-alone station configurations R S T U 0 1 Stand-alone station configurations SIMATIC HMI IPC477C 6AV7884- 7 A H 3 0 - 7 E 7 0 SIMATIC HMI IPC477C PRO 6AV7883- 7 A H 3 0 - 7 E 7 0 Core2 Duo processor 1.2 GHz, PROFIBUS DP, 4 GB SDRAM-DDR3 • 8 GB CF card • 50 GB SSD (High Endurance) • Runtime license 128 PT • Runtime license 2048 PT 1) Preferred versions with repaired replacement device from warehouse 2) Only together from 2 GB main memory 3) Only with IPC477C 4) with WES 2009: SP2; with WES 7: SP3 Siemens ST 80 / ST PC · 2013 6AV7883- 7 A 7 7 0 - 7 E 7 0 Fanless, 4 x USB 2.0 (500 mA), 1 x USB 2.0 on front (except PRO), 1 x COM (RS232), 24 VDC power supply with On/Off switch, 2 x PROFINET (IE), Windows Embedded Standard 7 SP1 pre-installed, SIMATIC WinCC Professional V11 SP2 B • HMI RT: WinCC flexible 2008 4) or w/o HMI software • HMI RT: WinCC Advanced V11 SP2 (TIA Portal), only with WES7 SP1 and 2 GB RAM 5/112 6AV7884- 7 A 7 7 0 - 7 E 7 0 Fanless 4 x USB 2.0 at rear, 1 x USB 2.0 at front, 1 x COM (RS232), 2 x 10/100/1000 Mbit/s Ethernet (RJ45); software pre-installed on CF/SSD: Windows Embedded Standard 7 SP1, SIMATIC WinCC Professional V11 SP2 4 6 Y V © Siemens AG 2013 PC-based Automation Embedded bundles/Software packages SIMATIC HMI IPC477C bundles ■ Ordering data Order No. Order No. Bundles with WinCC V7.0 SP2 incl. Update 1 ("Built to order" with max. delivery time of 14 working days; only repairs are possible for hardware) SIMATIC HMI IPC477C Accessories 6AV7884- 7 A 7 7 0 - 7 B 7 0 Fanless 4 x USB 2.0 at rear, 1 x USB 2.0 at front, 1 x COM (RS232), 2 x 10/100/1000 Mbit/s Ethernet (RJ45); software pre-installed on CF/SSD: Windows Embedded Standard, SIMATIC WinCC V7.0 SP1 SIMATIC HMI IPC477C PRO 6AV7883- 7 A 7 7 0 - 7 B 7 0 Fanless, 5 x USB 2.0 (500 mA), 1 x USB 2.0 at front (not on PRO), 1 x COM (RS232), 24 V DC power supply with On/Off switch, 2 x PROFINET (IE), Windows Embedded 2009 pre-installed, SIMATIC WinCC V7.0 SP2 incl. Update 1 Runtime pre-installed Front panel • 15" TFT Touch • 19" TFT Touch • 15" TFT Touch PRO • 19" TFT Touch PRO 6AV78846AV78846AV78836AV7883- Protective film for Panel PCs 477/577/677 For protecting the touch screen against dirt/scratches • for 12" Touch • for 15" Touch (not for PRO) • for 19" Touch 6AV7671-2BA00-0AA0 6AV7671-4BA00-0AA0 6AV7672-1CE00-0AA0 Labeling membranes for Panel PCs 477/577/677 For labeling soft keys and function keys, blank, supplied in sets of 10 6AV7672-0DA00-0AA0 Touch pen Captive pen for operation of the touch devices; holder can be mounted on the control cabinet or direct on the PRO unit 6AV7672-1JB00-0AA0 Expansion components From page 5/153 2 5 6 7 Client configurations Celeron M processor 1.2 GHz, 1 GB DDR3 RAM, 4 GB CF card, runtime license 128 PT A 1 3 X • Core2 Solo processor 1.2 GHz, 2 GB SDRAM-DDR3, 8 GB CF card, runtime license 128 PT D 2 4 X • Core2 Solo processor 1.2 GHz, PROFIBUS DP, 2 GB SDRAM-DDR3, 8 GB CF card, runtime license 128 PT E 2 4 X Client and stand-alone station configurations 5 Stand-alone station configurations SIMATIC HMI IPC477C 6AV7884- 7 A H 3 0 - 7 B 7 0 SIMATIC HMI IPC477C PRO 6AV7883- 7 A H 3 0 - 7 B 7 0 Core2 Duo processor 1.2 GHz, PROFIBUS DP, 4 GB SDRAM-DDR3 • 8 GB CF card • 50 GB SSD (High Endurance) • Runtime license 128 PT • Runtime license 2048 PT 4 6 X W Note: Please be sure to note: Other ready-to-use SIMATIC HMI IPC477Cs can be found in the Panel PC chapter under HMI IPC477C. The HMI IPC477C is delivered as standard with an inserted CF card. The licenses are located on the supplied USB flash drive. Siemens ST 80 / ST PC · 2013 5/113 © Siemens AG 2013 PC-based Automation Embedded bundles/Software packages Software packages for SIMATIC IPC and S7-mEC ■ Overview HMI complete systems SIMATIC IPC and S7-mEC with SIMATIC WinCC flexible • SIMATIC IPC packages with WinCC flexible are an innovative solution for simple visualization tasks directly at the machine in the field of HMI. • This package can only be supplied if a SIMATIC IPC or S7-mEC (same quantity) is ordered together with the WinCC flexible Runtime software. It cannot be ordered subsequently. • In combination with the embedded SIMATIC IPC (HMI IPC477C (PRO) and IPC427C) and the embedded controller S7-mEC, there are turn-key solutions (bundles), i.e. the runtime software is already preinstalled. SIMATIC IPC with SIMATIC WinCC (TIA Portal) • The SIMATIC IPC packages with WinCC make it easy to order all the components required for an HMI solution on the basis of a Panel PC. • This package can only be supplied if a SIMATIC IPC (same quantity) is ordered together with the WinCC RT Advanced or WinCC RT Professional software. It cannot be ordered subsequently. • In combination with the embedded SIMATIC IPC (IPC277D / HMI IPC477C (PRO) / IPC477D and IPC227D / IPC427C / IPC427D) there are turn-key solutions (bundles) available, i.e. the runtime software is already preinstalled. SIMATIC IPC with SIMATIC WinAC RTX (F) • The SIMATIC IPC packages with WinAC RTX (F) make it easy to order all the components required for a control solution on the basis of an industrial PC. • This package can only be supplied if a SIMATIC Industrial PC (same quantity) is ordered together with the WinAC RTX Runtime software. It cannot be ordered subsequently. • In combination with the embedded SIMATIC IPC (IPC277D / HMI IPC477C (PRO) / IPC477D and IPC227D / IPC427C / IPC427D) and the S7-mEC embedded controller, there are turn-key solutions (bundles) available, i.e. the runtime software is already preinstalled. 5 5/114 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation Embedded bundles/Software packages Software packages for SIMATIC IPC and S7-mEC ■ Ordering data Order No. SIMATIC WinCC flexible package 1) 3) (incl. archives and recipes) 6AV6623- 2 7 A 0 0 - 0 A A 0 WinCC flexible 2008 Runtime • 128 PowerTags • 512 PowerTags • 2048 PowerTags • 4096 PowerTags SIMATIC WinCC package 2) B D F G 6AV6382- 2 7 A 0 7 - 2 A X 0 WinCC V7.2 Runtime 2) • 128 PowerTags • 256 Power Tags • 1 024 PowerTags • 8 192 PowerTags • 65 536 PowerTags C D E H F SIMATIC WinCC package 2) WinCC V7.0 SP3 Runtime • 128 PowerTags • 512 PowerTags • 2 048 PowerTags • 8 192 PowerTags • 65 536 PowerTags Order No. 6AV6382- 2 7 A 0 7 - 0 A X 0 2) C D E H F 1) Only if ordered together with a SIMATIC IPC, SIMATIC Panel PC Ex, or S7-mEC 2) Only if ordered together with a SIMATIC IPC 3) The current version will always be supplied SIMATIC WinCC (TIA Portal) WinCC Runtime Advanced Package 1)3) 6AV2114- 2 7 A 0 0 - 0 A A 0 Incl. Recipes + Logging • 128 PowerTags • 512 PowerTags • 2048 PowerTags • 4096 PowerTags SIMATIC WinCC Runtime Professional Package 2)3) • 128 PowerTags • 512 PowerTags • 2048 PowerTags • 4096 PowerTags • 8192 PowerTags • 65536 PowerTags B D F H 6AV2115- 2 7 A 0 0 - 0 A A 0 B D F H K M 1) Only if ordered together with a SIMATIC IPC, SIMATIC Panel PC Ex, or S7-mEC 2) Only if ordered together with a SIMATIC IPC 3) The current version will always be supplied SIMATIC WinAC RTX (F) package • SIMATIC WinAC RTX 1) 2) • SIMATIC WinAC RTX F 1) 2) Ready-to-use SIMATIC HMI IPC477C with WinCC ("Built to order" with max. delivery time of 14 working days; only repairs are possible for hardware) 6AV7884- 7 A 7 7 0 - 7 B 7 0 SIMATIC HMI IPC477C with WinCC V7.0 Fanless, 5 x USB2.0 (500 mA), 1 of which at front, 1 x COM (RS232), power supply 24 V DC with On/Off switch, 2 x PROFINET (IE), 2 GB main memory (DDR3-SDRAM), CompactFlash Card 8 GB; Windows Embedded 2009 preinstalled; SIMATIC WinCC V7.0 SP2 Runtime preinstalled Client configurations 7AA 1 0 - 4 BX 0 Celeron M processor, 1.2 GHz, 1 GB SDRAM-DDR3, 8 GB CF card, runtime license 128 PT • 15" Touch • 19" Touch 3 5 Client and stand-alone station configurations Core2 Solo processor 1.2 GHz, 2 GB SDRAM-DDR3, 8 GB CF card, runtime license 128 PT • 15" Touch • 19" Touch 7AE 2 0 - 4 BX 0 3 5 7AH 3 0 -7B7 0 Stand-alone station configurations Processor Core2 Duo 1.2 GHz, 4 GB SDRAM-DDR3 • 15" Touch • 19" Touch • 8 GB CF card • 50 GB SSD • Runtime license 128 PT • Runtime license 2048 PT 5 3 5 7 7 7 7 A A A A H H H H 3 3 3 3 0 0 0 0 - 4 6 7BX 0 7 BW 0 6ES7671-0RC08-6YA0 6ES7671-1RC08-6YA0 1) Only if ordered together with a SIMATIC IPC 2) The current version will always be supplied Note: For ordering data for Panel PCs and accessories, see configurators in "SIMATIC Panel PCs". Siemens ST 80 / ST PC · 2013 5/115 © Siemens AG 2013 PC-based Automation Embedded bundles/Software packages Software packages for SIMATIC IPC and S7-mEC ■ Ordering data ■ More information Order No. Further information can be found in the Internet at: HMI IPC477C / HMI IPC477C PRO with WinCC RT Professional (TIA Portal) http://www.automation.siemens.com/simatic-hmi ("Built to order" version, max. delivery time of 15 working days and with identified repair, if not preferred type) SIMATIC HMI IPC477C with WinCC RT Professional (TIA Portal) 6AV788 4 - 7 A 7 7 0 - 7 E 7 0 SIMATIC HMI IPC477C PRO with WinCC RT Professional (TIA Portal) 6AV788 3 - 7 A 7 7 0 - 7 E 7 0 Fan-free 5 x USB 2.0 (500 mA), one of which on the front 1 x COM (RS232) 24 V DC power supply with On/Off switch, 2 x PROFINET (IE), 2 GB main memory (DDR3-SDRAM), CompactFlash Card 8 GB, Windows Embedded Standard 7 SP1 pre-installed, SIMATIC WinCC RT Professional V11 SP2 pre-installed Front panels • 15" Touch • 15" Touch PRO • 19" Touch • 19" Touch PRO 4 3 4 3 Client configurations 7-7AA 2 0 - 4 E Y 0 3 6 5 7 Core2 Solo processor 1.2 GHz, 2 GB SDRAM-DDR3, 8 GB CF card, runtime license 128 PT 5 Client and stand-alone station configurations 4 - 7 A A 2 0 - 4 E Y 0 Core2 Solo processor 1.2 GHz, 2 GB SDRAM-DDR3, 8 GB CF card, runtime license 128 PT Stand-alone station configurations Processor Core2 Duo 1.2 GHz, 4 GB SDRAM-DDR3 • 8 GB CF card • 50 GByte SSDe • Runtime license 128 PT • Runtime license 2048 PT 4 - 7 A H 3 0 - 7 E 7 0 7-7AH 3 0 - 4 E7 0 6 7-7AH 3 0 -7 E Y 0 V Note: Other ready-to-use SIMATIC HMI IPC477Cs can be found in the Panel PC chapter under HMI IPC477C. 5/116 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation Industrial monitors and thin clients SIMATIC Industrial Flat Panel MT ■ Overview SIMATIC IFP1900 MT Flat Panel Monitor – industrial monitors with innovative multi-touch operation and brilliant display for the next generation of operating concepts. • Installation: - Equally suited to installation in machines, control cabinets, consoles, and gantries or in 19" racks • Operator input options: - Innovative projected capacitive touch technology (PCT) - Optimized touch technology for industrial requirements with multi-touch operation - High protection against incorrect operation thanks to detection and filtering out of ball of hand, drops of water, and cleaning operations ■ Technical specifications 6AV7466-7TB01-0AA0 6AV7466-7TB01-0AA0 IFP1900 MT Display Screen diagonal 18.5 in Screen diagonal (cm) 47 cm Display width 409.8 mm Display height 230.4 mm Viewing angle 170° x 170° Type TFT widescreen display, LED backlighting On Screen Display (OSD) configuration No, can be set with the software Number of colors (bit levels) 24 bit Resolution (pixels) • Resolution (WxH in pixel) 1366 x 768 General features • Detachable from computer unit 30 m Backlighting • Backlighting (type) • MTBF backlighting (up to 50%, at 25 °C) • Dimmable backlight LED 50 000 h; At 25°C Yes; 0-100 % IFP1900 MT Control elements Function keys No Mouse/cursor control • external mouse USB Touch operation • Touch keyboard Yes Installation type/mounting Built-in unit • Permissible angle to the vertical backward (console) • Permissible angle to the vertical forward (ceiling mounting) Yes 35° 5 35° Supply voltage Type of actuation • AC • DC AC, DC Yes Yes Rated voltage (AC) 0V Rated voltage (DC) 24 V permissible range, lower limit (DC) 19.2 V permissible range, upper limit (DC) 28.8 V permissible range, lower limit (AC) 85 V permissible range, upper limit (AC) 265 V Siemens ST 80 / ST PC · 2013 5/117 © Siemens AG 2013 PC-based Automation Industrial monitors and thin clients SIMATIC Industrial Flat Panel MT ■ Technical specifications (continued) 6AV7466-7TB01-0AA0 6AV7466-7TB01-0AA0 IFP1900 MT Power losses Power loss AC • Typical • Maximum 40 W 60 W Power loss DC • Typical • Maximum 40 W 65 W Interfaces USB on the rear 2 Video interfaces • DVI-D • Display port Yes Yes; Display port V1.1 Touch interfaces • USB Yes Degree and class of protection IP65 at front Yes Enclosure Type 4 at the front Yes NEMA4 at the front No NEMA4X at the front IP20 rear Standards, approvals, certificates CE 5 0 °C Max. ambient temperature 45 °C Storage/transport temperature • Min. • max. -20 °C 60 °C Relative humidity • Relative humidity during operation 95 % Connection method Connector for cooling devices Yes Mechanics/material Type of housing (front) • Aluminum Aluminum Yes Dimensions Width of the housing front 483 mm Height of housing front 337 mm No Mounting cutout (W x H x D) • Mounting cutout, width • Mounting cutout, height 465 mm 319 mm Yes Depth/installation dimension 62.5 mm Yes Weight Weight without packaging 6.34 kg Weight incl. packaging 9.52 kg UL approval • UL 508 Yes cULus Yes EN 50081-1 Yes EN 50081-2 Yes EN 50082-1 Yes EN 50082-2 Yes 5/118 IFP1900 MT Ambient conditions Min. ambient temperature Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation Industrial monitors and thin clients SIMATIC Industrial Flat Panel MT Order No. 6AV7466-7TB01-0AA0 ■ Dimensional drawings All dimensions in mm. For mounting cut-out see technical specifications. H D W 6.5 W+1 G_ST80_XX_00522 SIMATIC IFP1900 MT Flat Panel, 19" display (16:9), operation using multitouch gestures, extended version up to 30 m, 1366 x 768 pixels, for 24 V DC and 100-240 V AC, display port/DVI interface, incl. 1.8 m DVI/USB cable H+1 ■ Ordering data Mounting dimensions Industrial Flat Panel MT IFP1900 Front dimensions in mm Mounting Cutout, in mm W H W+1 H+1 D 483 337 465 319 93 5 Siemens ST 80 / ST PC · 2013 5/119 © Siemens AG 2013 PC-based Automation Industrial monitors and thin clients SIMATIC Industrial Flat Panel ■ Overview The Industrial Flat Panels are rugged industry-standard LCD monitors in a wide screen design. • Installation: - Equally suited for installation in the machine, in control cabinets, in consoles, to gantries, or in 19" racks. • Type of operator control: - Simple display devices without operator functionality - Optional devices with touch control - Rear-mounted connection of I/O devices (optional). ■ Technical specifications 5 6AV7863-2AA00-0AA0 IFP1500 6AV7863-2AB10-0AA0 IFP1500 6AV7863-2TA00-0AA0 IFP1500 6AV7863-2TB10-0AA0 IFP1500 General information Short designation Flat Panel 15" display Flat Panel 15" display ext. Flat Panel 15" Touch Flat Panel 15" Touch ext. Display Screen diagonal 15.4 in 15.4 in 15.4 in 15.4 in Screen diagonal (cm) 40 cm 40 cm 40 cm 40 cm Display width 331.2 mm 331.2 mm 331.2 mm 331.2 mm Display height 207 mm 207 mm 207 mm 207 mm Viewing angle 170° x 170° 170° x 170° 170° x 170° 170° x 170° Type TFT widescreen display, LED backlighting TFT widescreen display, LED backlighting TFT widescreen display, LED backlighting TFT widescreen display, LED backlighting On Screen Display (OSD) configuration No, can be set with the software No, can be set with the software No, can be set with the software No, can be set with the software Number of colors (bit levels) 24 bit 24 bit 24 bit 24 bit Number of colors 16 777 200 16 777 200 16 777 200 16 777 200 Resolution (pixels) • Horizontal image resolution • Vertical image resolution • Pixel size, horizontal • Pixel size, vertical 1 280 800 0.259 mm 0.259 mm 1 280 800 0.259 mm 0.259 mm 1 280 800 0.259 mm 0.259 mm 1 280 800 0.259 mm 0.259 mm Yes Yes 5m 400 cd/m² / 1000:1 400 cd/m² 30 m 400 cd/m² / 1000:1 400 cd/m² 5m 400 cd/m² / 1000:1 400 cd/m² 5m 400 cd/m² / 1000:1 400 cd/m² LED 50 000 h; At 25°C LED 50 000 h; At 25°C LED 50 000 h; At 25°C LED 50 000 h; At 25°C Yes; 0-100 % Yes; 0-100 % Yes; 0-100 % Yes; 0-100 % General features • Non-reflective and tempered mineral glass screen • Detachable from computer unit • Brightness/contrast • Brightness, max. Backlighting • Backlighting (type) • MTBF backlighting (up to 50%, at 25 °C) • Dimmable backlight 5/120 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation Industrial monitors and thin clients SIMATIC Industrial Flat Panel ■ Technical specifications (continued) Control elements Function keys 6AV7863-2AA00-0AA0 IFP1500 6AV7863-2AB10-0AA0 IFP1500 6AV7863-2TA00-0AA0 IFP1500 6AV7863-2TB10-0AA0 IFP1500 No No No No Mouse/cursor control • external mouse USB Keyboard fonts • Alphanumeric and numeric block Yes Touch operation • Touch keyboard Installation type/mounting Built-in unit • Permissible angle to the vertical backward (console) • Permissible angle to the vertical forward (ceiling mounting) Supply voltage Type of actuation • AC • DC USB Yes Yes Yes 35° Yes 35° Yes 35° Yes 35° 35° 35° 35° 35° DC DC Yes Yes DC Yes DC Yes Yes Yes 100 V; Up to 240V 50/60Hz Rated voltage (AC) Rated voltage (DC) 24 V 24 V 24 V 24 V permissible range, lower limit (DC) 19.2 V 19.2 V 19.2 V 19.2 V permissible range, upper limit (DC) 28.8 V 28.8 V 28.8 V 28.8 V permissible range, lower limit (AC) 90 V 90 V permissible range, upper limit (AC) 264 V 264 V Power losses Power loss AC • Typical • Maximum 40 W 60 W 40 W 60 W Power loss DC • Typical • Maximum 40 W 65 W Interfaces USB on the rear 40 W 65 W 40 W 65 W 5 40 W 65 W 2 2 Video interfaces • DVI-D • Display port Yes Yes; Display port V1.1 Yes Yes; Display port V1.1 Yes Yes; Display port V1.1 Yes Yes; Display port V1.1 Touch interfaces • USB No No Yes Yes Degree and class of protection IP65 at front Yes Yes Yes Yes Enclosure Type 4 at the front Yes Yes Yes Yes NEMA4 at the front No No No No NEMA4X at the front No No No No IP20 rear Yes Yes Yes Yes Siemens ST 80 / ST PC · 2013 5/121 © Siemens AG 2013 PC-based Automation Industrial monitors and thin clients SIMATIC Industrial Flat Panel ■ Technical specifications (continued) 6AV7863-2AA00-0AA0 IFP1500 6AV7863-2AB10-0AA0 IFP1500 6AV7863-2TA00-0AA0 IFP1500 6AV7863-2TB10-0AA0 IFP1500 Standards, approvals, certificates CE Yes Yes Yes Yes KC approval Yes Yes Yes Yes cULus Yes; Corresponds to UL 508 Yes; Corresponds to UL 508 Yes; Corresponds to UL 508 Yes; Corresponds to UL 508 C-TICK Yes Yes Yes Yes GL Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon ABS Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon BV Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon DNV Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon LRS Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon Class NK Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon Use in hazardous areas • ATEX Zone 22 • FM Class I Division 2 Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon Ambient conditions Min. ambient temperature 0 °C 0 °C 0 °C 0 °C 50 °C; Vertical installation (horizontal) 50 °C; Vertical installation (horizontal) 50 °C; Vertical installation (horizontal) 50 °C; Vertical installation (horizontal) Storage/transport temperature • Min. • max. -20 °C 60 °C -20 °C 60 °C -20 °C 60 °C -20 °C 60 °C Relative humidity • Relative humidity during operation 95 %; Non-condensing 95 %; Non-condensing 95 %; Non-condensing 95 %; Non-condensing 1g 1g 1g 1g 1g 1g 1g 1g 15 g 15 g 15 g 15 g 15 g 15 g 15 g 15 g Max. ambient temperature Vibrations • Vibration load in operation • Vibration load during transport/storage 5 Shock testing • Shock loading in operation • Shock load during transport/storage Connection method Connector for cooling devices Yes Mechanics/material Type of housing (front) • Aluminum Aluminum Yes Aluminum Yes Aluminum Yes Aluminum Yes Dimensions Width of the housing front 415 mm 415 mm 415 mm 415 mm Height of housing front 310 mm 310 mm 310 mm 310 mm Depth/installation dimension 62.5 mm 62.5 mm 62.5 mm 62.5 mm Mounting cutout, width 396 mm; Tolerance: +1 mm 396 mm; Tolerance: +1 mm 396 mm; Tolerance: +1 mm 396 mm; Tolerance: +1 mm Mounting cutout, height 291 mm; Tolerance: +1 mm 291 mm; Tolerance: +1 mm 291 mm; Tolerance: +1 mm 291 mm; Tolerance: +1 mm Weight Weight without packaging 3.9 kg 3.9 kg 3.9 kg 3.9 kg Weight incl. packaging 5 kg 5 kg 5 kg 5 kg 5/122 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation Industrial monitors and thin clients SIMATIC Industrial Flat Panel ■ Technical specifications (continued) 6AV7 863-3AA00-0AA0 IFP1900 6AV7 863-3AB10-0AA0 IFP1900 6AV7 863-3TA00-0AA0 IFP1900 6AV7 863-3TB10-0AA0 IFP1900 General information Short designation Flat Panel 19" display Flat Panel 19" display ext. Flat Panel 19" Touch Flat Panel 19" Touch ext. Display Screen diagonal 18.5 in 18.5 in 18.5 in 18.5 in Screen diagonal (cm) 47 cm 47 cm 47 cm 47 cm Display width 409.8 mm 409.8 mm 409.8 mm 409.8 mm Display height 230.4 mm 230.4 mm 230.4 mm 230.4 mm Type TFT TFT TFT TFT On Screen Display (OSD) configuration No, can be set with the software No, can be set with the software No, can be set with the software No, can be set with the software Number of colors (bit levels) 24 bit 24 bit 24 bit 24 bit Resolution (pixels) • Resolution (WxH in pixel) • Pixel size, horizontal • Pixel size, vertical 1366 x 768 0.3 mm 0.3 mm 1366 x 768 0.3 mm 0.3 mm 1366 x 768 0.3 mm 0.3 mm 1366 x 768 0.3 mm 0.3 mm Yes Yes 5m 30 m 5m 30 m LED 50 000 h; At 25°C LED 50 000 h; At 25°C LED 50 000 h; At 25°C LED 50 000 h; At 25°C Yes; 0-100 % Yes; 0-100 % Yes; 0-100 % Yes; 0-100 % No No No No General features • Non-reflective and tempered mineral glass screen • Detachable from computer unit Backlighting • Backlighting (type) • MTBF backlighting (up to 50%, at 25 °C) • Dimmable backlight Control elements Function keys Mouse/cursor control • external mouse USB Touch operation • Touch keyboard Installation type/mounting Built-in unit • Permissible angle to the vertical backward (console) • Permissible angle to the vertical forward (ceiling mounting) USB Yes Yes Yes 35° Yes 35° Yes 35° Yes 35° 35° 35° 35° 35° Siemens ST 80 / ST PC · 2013 5 5/123 © Siemens AG 2013 PC-based Automation Industrial monitors and thin clients SIMATIC Industrial Flat Panel ■ Technical specifications (continued) Supply voltage Type of actuation • AC • DC 6AV7 863-3AA00-0AA0 IFP1900 6AV7 863-3AB10-0AA0 IFP1900 6AV7 863-3TA00-0AA0 IFP1900 6AV7 863-3TB10-0AA0 IFP1900 DC DC Yes Yes DC DC Yes Yes Yes 100 V; Up to 240V 50/60Hz Rated voltage (DC) 24 V 24 V 24 V 24 V permissible range, lower limit (DC) 19.2 V 19.2 V 19.2 V 19.2 V permissible range, upper limit (DC) 28.8 V 28.8 V 28.8 V 28.8 V permissible range, lower limit (AC) 90 V 90 V permissible range, upper limit (AC) 264 V 264 V Power losses Power loss AC • Typical • Maximum 40 W 60 W 40 W 60 W Power loss DC • Typical • Maximum 40 W 65 W Interfaces USB on the rear 5 Yes 100 V; Up to 240V 50/60Hz Rated voltage (AC) 40 W 65 W 40 W 65 W 2 40 W 65 W 2 Video interfaces • DVI-D • Display port Yes Yes; Display port V1.1 Yes Yes; Display port V1.1 Yes Yes; Display port V1.1 Yes Yes; Display port V1.1 Touch interfaces • USB No No Yes Yes Degree and class of protection IP65 at front Yes Yes Yes Yes Enclosure Type 4 at the front Yes Yes Yes Yes NEMA4 at the front No No No No NEMA4X at the front No No No No IP20 rear Yes Yes Yes Yes Standards, approvals, certificates CE Yes Yes Yes Yes KC approval Yes Yes Yes Yes cULus Yes; Corresponds to UL 508 Yes; Corresponds to UL 508 Yes; Corresponds to UL 508 Yes; Corresponds to UL 508 C-TICK Yes Yes Yes Yes GL Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon ABS Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon BV Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon DNV Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon LRS Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon Class NK Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon Use in hazardous areas • ATEX Zone 22 • FM Class I Division 2 Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon 5/124 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation Industrial monitors and thin clients SIMATIC Industrial Flat Panel ■ Technical specifications (continued) 6AV7 863-3AA00-0AA0 IFP1900 6AV7 863-3AB10-0AA0 IFP1900 6AV7 863-3TA00-0AA0 IFP1900 6AV7 863-3TB10-0AA0 IFP1900 0 °C 0 °C 0 °C 0 °C 45 °C; Vertical installation (horizontal) 45 °C; Vertical installation (horizontal) 45 °C; Vertical installation (horizontal) 45 °C; Vertical installation (horizontal) Storage/transport temperature • Min. • max. -20 °C 60 °C -20 °C 60 °C -20 °C 60 °C -20 °C 60 °C Relative humidity • Relative humidity during operation 95 %; Non-condensing 95 %; Non-condensing 95 %; Non-condensing 95 %; Non-condensing 1g 1g 1g 1g 1g 1g 1g 1g 15 g 15 g 15 g 15 g 15 g 15 g 15 g 15 g Ambient conditions Min. ambient temperature Max. ambient temperature Vibrations • Vibration load in operation • Vibration load during transport/storage Shock testing • Shock loading in operation • Shock load during transport/storage Connection method Connector for cooling devices Yes Yes Mechanics/material Type of housing (front) • Aluminum Aluminum Yes Aluminum Yes Aluminum Yes Aluminum Yes Dimensions Width of the housing front 483 mm 483 mm 483 mm 483 mm Height of housing front 337 mm 337 mm 337 mm 337 mm Mounting cutout (W x H x D) • Mounting cutout, width • Mounting cutout, height 465 mm; Tolerance: +1 mm 319 mm; Tolerance: +1 mm 465 mm; Tolerance: +1 mm 319 mm; Tolerance: +1 mm 465 mm; Tolerance: +1 mm 319 mm; Tolerance: +1 mm 465 mm; Tolerance: +1 mm 319 mm; Tolerance: +1 mm Depth/installation dimension 62.5 mm 62.5 mm 62.5 mm 62.5 mm Weight Weight without packaging 5.5 kg 5.5 kg 5.5 kg 5.5 kg Weight incl. packaging 6.5 kg 6.5 kg 6.5 kg 6.5 kg Siemens ST 80 / ST PC · 2013 5 5/125 © Siemens AG 2013 PC-based Automation Industrial monitors and thin clients SIMATIC Industrial Flat Panel ■ Technical specifications (continued) 6AV7 863-4AA00-0AA0 IFP2200 6AV7 863-4AB10-0AA0 IFP2200 6AV7 863-4TA00-0AA0 IFP2200 6AV7 863-4TB10-0AA0 IFP2200 General information Short designation Flat Panel 22" display Flat Panel 22" display ext. Flat Panel 19" Touch Flat Panel 22" Touch ext. Display Screen diagonal 21.5 in 21.5 in 21.5 in 21.5 in Screen diagonal (cm) 56 cm 56 cm 56 cm 56 cm Display width 476 mm 476 mm 476 mm 476 mm Display height 268 mm 268 mm 268 mm 268 mm Viewing angle 170° x 170° 170° x 170° 170° x 170° 170° x 170° Type TFT TFT TFT TFT On Screen Display (OSD) configuration No, can be set with the software No, can be set with the software No, can be set with the software No, can be set with the software Number of colors (bit levels) 24 bit 24 bit 24 bit 24 bit Resolution (pixels) • Resolution (WxH in pixel) • Pixel size, horizontal • Pixel size, vertical 1920 x 1080 0.2475 mm 0.2475 mm 1920 x 1080 0.2475 mm 0.2475 mm 1920 x 1080 0.2475 mm 0.2475 mm 1920 x 1080 0.2475 mm 0.2475 mm Yes Yes 5m 250 cd/m² / 1000:1 30 m 250 cd/m² / 1000:1 5m 250 cd/m² / 1000:1 30 m 250 cd/m² / 1000:1 LED 50 000 h; At 25°C LED 50 000 h; At 25°C LED 50 000 h; At 25°C LED 50 000 h; At 25°C Yes; 0-100 % Yes; 0-100 % Yes; 0-100 % Yes; 0-100 % No No No No General features • Non-reflective and tempered mineral glass screen • Detachable from computer unit • Brightness/contrast Backlighting • Backlighting (type) • MTBF backlighting (up to 50%, at 25 °C) • Dimmable backlight Control elements Function keys 5 Mouse/cursor control • external mouse USB Touch operation • Touch keyboard Installation type/mounting Built-in unit • Permissible angle to the vertical backward (console) • Permissible angle to the vertical forward (ceiling mounting) Supply voltage Type of actuation • AC • DC USB Yes Yes Yes 35° Yes 35° Yes 35° Yes 35° 35° 35° 35° 35° DC DC Yes Yes DC DC Yes Yes Yes Yes 100 V; Up to 240V 50/60Hz Rated voltage (AC) 100 V; Up to 240V 50/60Hz Rated voltage (DC) 24 V 24 V 24 V 24 V permissible range, lower limit (DC) 19.2 V 19.2 V 19.2 V 19.2 V permissible range, upper limit (DC) 28.8 V 28.8 V 28.8 V 28.8 V permissible range, lower limit (AC) 90 V 90 V permissible range, upper limit (AC) 264 V 264 V 5/126 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation Industrial monitors and thin clients SIMATIC Industrial Flat Panel ■ Technical specifications (continued) 6AV7 863-4AA00-0AA0 IFP2200 Power losses Power loss AC • Typical • Maximum Power loss DC • Typical • Maximum 6AV7 863-4AB10-0AA0 IFP2200 6AV7 863-4TA00-0AA0 IFP2200 40 W 60 W 40 W 65 W Interfaces USB on the rear 40 W 65 W 6AV7 863-4TB10-0AA0 IFP2200 40 W 60 W 40 W 65 W 40 W 65 W 2 2 Video interfaces • DVI-D • Display port Yes Yes; Display port V1.1 Yes Yes; Display port V1.1 Yes Yes; Display port V1.1 Yes Yes; Display port V1.1 Touch interfaces • USB No No Yes Yes Degree and class of protection IP65 at front Yes Yes Yes Yes Enclosure Type 4 at the front Yes Yes Yes Yes NEMA4 at the front No No No No NEMA4X at the front No No No No IP20 rear Yes Yes Yes Yes Standards, approvals, certificates CE Yes Yes Yes Yes KC approval Yes Yes Yes Yes cULus Yes; Corresponds to UL 508 Yes; Corresponds to UL 508 Yes; Corresponds to UL 508 Yes; Corresponds to UL 508 C-TICK Yes Yes Yes Yes GL Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon ABS Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon BV Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon DNV Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon LRS Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon Class NK Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon Use in hazardous areas • ATEX Zone 22 • FM Class I Division 2 Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon Ambient conditions Min. ambient temperature 0 °C 0 °C 0 °C 0 °C 45 °C; Vertical installation (horizontal) 45 °C; Vertical installation (horizontal) 45 °C; Vertical installation (horizontal) 45 °C; Vertical installation (horizontal) Storage/transport temperature • Min. • max. -20 °C 60 °C -20 °C 60 °C -20 °C 60 °C -20 °C 60 °C Relative humidity • Relative humidity during operation 95 %; Non-condensing 95 %; Non-condensing 95 %; Non-condensing 95 %; Non-condensing 1g 1g 1g 1g 1g 1g 1g 1g 15 g 15 g 15 g 15 g 15 g 15 g 15 g 15 g Max. ambient temperature Vibrations • Vibration load in operation • Vibration load during transport/storage Shock testing • Shock loading in operation • Shock load during transport/storage Siemens ST 80 / ST PC · 2013 5/127 5 © Siemens AG 2013 PC-based Automation Industrial monitors and thin clients SIMATIC Industrial Flat Panel ■ Technical specifications (continued) 6AV7 863-4AA00-0AA0 IFP2200 Connection method Connector for cooling devices 6AV7 863-4TA00-0AA0 IFP2200 Yes 6AV7 863-4TB10-0AA0 IFP2200 Yes Mechanics/material Type of housing (front) • Aluminum Aluminum Yes Aluminum Yes Aluminum Yes Aluminum Yes Dimensions Width of the housing front 560 mm 560 mm 560 mm 560 mm Height of housing front 380 mm 380 mm 380 mm 380 mm Mounting cutout (W x H x D) • Mounting cutout, width • Mounting cutout, height 542 mm; Tolerance: +1 mm 362 mm; Tolerance: +1 mm 542 mm; Tolerance: +1 mm 362 mm; Tolerance: +1 mm 542 mm; Tolerance: +1 mm 362 mm; Tolerance: +1 mm 542 mm; Tolerance: +1 mm 362 mm; Tolerance: +1 mm Depth/installation dimension 62.5 mm 62.5 mm 62.5 mm 62.5 mm Weight Weight without packaging 6.5 kg 6.5 kg 6.5 kg 6.5 kg Weight incl. packaging 7.6 kg 7.6 kg 7.6 kg 7.6 kg ■ Ordering data Industrial Flat Panel Monitor Order No. Order No. 6AV7863- 7 7 7 7 - 0 A A 0 Display size • 15“ • 19“ • 22“ 5 6AV7 863-4AB10-0AA0 IFP2200 2 3 4 Operator functionality • Display devices without operator functionality • Touch screen (analog/resistive) • Touch screen + function keys, 15" only and extended special functions Special functions • Standard, can be located up to 5 m away • Extended, for positioning at a distance of up to 30 m, 100 ... 230 V AC (without supply cable) + special functions A T BB1 Accessories Set of protective films for ITC/IFP/TP1500 6AV2124-6QJ00-0AX1 Set of protective films for ITC/IFP/TP1900 6AV2124-6UJ00-0AX1 Set of protective films for ITC/IFP/TP2200 6AV2124-6XJ00-0AX1 Touch pen Undetachable pen for operation of the touch devices, mounting of the support on the control cabinet or directly on the PRO unit 6AV7672-1JB00-0AA0 A0 Accessories for standard variants up to 5 m (6AV7863-..A0.-0AA0) B1 DisplayPort cable (industrial quality) •3m •5m 6AV7860-0DH30-0AA0 6AV7860-0DH50-0AA0 DVI-D cable (industrial quality) •3m •5m 6AV7860-0BH30-0AA0 6AV7860-0BH50-0AA0 USB cable (industrial quality) •3m •5m 6AV7860-0CH30-0AA0 6AV7860-0CH50-0AA0 Accessories for extended variants up to 30 m (6AV7863-..B1.-0AA0) Cable set (USB/Cat5; sender module, DVI) • 10 m • 15 m • 20 m • 30 m 5/128 Siemens ST 80 / ST PC · 2013 6AV7860-1EX21-0AA1 6AV7860-1EX21-5AA1 6AV7860-1EX22-0AA1 6AV7860-1EX23-0AA1 Cable set 90° USB/Cat5; sender module, DVI 90° angle, 20 m 6AV7860-1EX22-0BA1 USB host extender incl. 20 cm USB cable (USB to Cat5) 6AV7671-1EX02-0AA0 © Siemens AG 2013 PC-based Automation Industrial monitors and thin clients SIMATIC Industrial Flat Panel ■ Dimensional drawings All dimensions in mm. For mounting cut-out see technical specifications. Mounting dimensions Industrial Flat Panel H D W Faceplate Dimensions, in mm Mounting Cutout, in mm W H W+1 H+1 D IF1500 Key/Touch 483 310 450 291 62.5 IFP1500 415 310 396 291 62.5 IFP1900 483 337 465 319 62.5 IFP2200 560 380 542 362 62.5 6.5 G_ST80_XX_00522 H+1 W+1 5 Siemens ST 80 / ST PC · 2013 5/129 © Siemens AG 2013 PC-based Automation Industrial monitors and thin clients SIMATIC Flat Panels ■ Overview The Flat Panels are rugged industry-standard LCD monitors. • Installation: - They are equally suited to installation in the machine, in control cabinets, consoles and gantries or in 19" racks. - As a device with all-round IP65 protection for mounting on a supporting arm/stand • Type of operator control: - Simple display devices without operator functionality - Optional devices with touch control - Rear connection of I/O devices (optional) ■ Technical specifications Flat Panel 12“ 15“ 19“ Supply voltage 24 V DC, additional option 100-240 V AC 24 V DC, additional option 100-240 V AC 24 V DC, additional option 100/240 V AC Permissible frequency range 47 - 63 Hz 47 - 63 Hz 47 - 63 Hz Power consumption, max. 25 VA 35 VA 55 VA Anti-glare and hardened mineral glass screen Yes Yes Yes Line side switch No No No Can be separate from the computer Optional up to 30 m Optional up to 30 m Optional up to 30 m On-screen display (OSD) configuration Yes Yes Yes Display version 12" TFT 15" TFT 19" TFT Visible area (HxV) in mm 246 x 184.5 304 x 228 376 x 301 Viewing angle 140° x 120° 140° x 120° (min) 170° x 170° Pixel pitch 0.3075 mm x 0.3075 mm 0.297 mm x 0.297 mm 0.294 mm x 0.294 mm Resolution (W x H in pixels) 800 x 600 1024 x 768 1280 x 1024 Refresh rate 60 - 75 Hz 60 - 75 Hz 60 - 75 Hz Line frequency 25 - 48 kHz 46.7 - 62.5 kHz 30 - 80 KHz Brightness/Contrast > 350 cd/m² / 450:1 > 260cd/m² / 350:1 > 300cd/m² / 300:1 Number of colors 262k 16.7 million 16.7 million MTBF backlit display (at 25 °C, 24 h continuous duty) 50.000 h 50.000 h 50.000 h Touch screen analog-resistive, optional analog-resistive, optional analog-resistive, optional Connection for mouse/keyboard/ barcode reader Yes, at rear, optionally via USB Yes, at rear, optionally via USB Yes, at rear, optionally via USB Front side according to EN 60529 IP65 IP65 IP65 Rear side according to EN 60529 IP20 IP20 IP20 Supply voltage General features 5 Display Type of operation Degree of protection 5/130 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation Industrial monitors and thin clients SIMATIC Flat Panels ■ Technical specifications (continued) Flat Panel 12“ 15“ 19“ Certification cULus (UL 508), NEMA4 tested cULus (UL 508), NEMA4 tested cULus (UL 508), NEMA4 tested EMC CE EN 55011 class A CE EN 55011 class A CE EN 55011 class A CE mark Yes Yes Yes UL approval Yes Yes Yes CCC marking Yes Yes Yes Vibration load during operation 1 g (10 m/s²) 1 g (10 m/s²) 1 g (10 m/s²) Shock loading during operation 5 g (50 m/s²) 5 g (50 m/s²) 5 g (50 m/s²) 5 to +50°C 5 to +50°C 5 to +45°C Rack mounting No No No Front mounting Yes (IP65) Yes (IP65) Yes (IP65) Angle of inclination for desk mounting -20°/+70° -20°/+70° -20°/+70° Graphics interface Standard VGA interface 15-pin Sub D / digital DVI-D interface Standard VGA interface 15-pin Sub D / digital DVI-D interface Standard VGA interface 15-pin Sub D / digital DVI-D interface Interface for Touch USB (V1.1) USB (V1.1) USB (V1.1) USB interface for touch screen Optional Optional Optional External dimensions (W x H x D) in mm 400 x 310 x 61.5 483 x 310 x 54 483 x 400 x 56 Installation cutout/device depth (W x H x D) in mm 368 x 290 x 51 450 x 290 x 54 449 x 380 x 56 5 kg 6.4 kg 10.2 kg Certifications & standards Standards, approvals, certificates Ambient conditions Temperature Ambient temperature during operation Mounting Interfaces Dimensions Weight Weight, approx. Siemens ST 80 / ST PC · 2013 5 5/131 © Siemens AG 2013 PC-based Automation Industrial monitors and thin clients SIMATIC Flat Panels ■ Ordering data Flat Panel Monitor Order No. Order No. 6AV7861- 7 7 7 7 0- 11 A A 0 Display size • 12“ • 15“ • 19“ Flat Panel Monitor • 12" Key • 15" Key • PRO 15" Touch • PRO 19" Touch 1 2 3 Operator functionality: • Display devices without operator functionality • Touch screen (analog/resistive) Power supply • 24 VDC (not for Extended versions since these always have AC and DC) • 100 to 230 V AC (incl. Euro power supply cable) and 24 V DC Version • Standard, can be located up to 5 m away • Extended, can be located up to 30 m away, marine approvals Dimmable background illumination Ex22 Special versions A Accessories T A 0 B 0 1 Protective films For protecting the touch screen against dirt and scratches Pack with 10 units • for 12" Touch • for 15" Touch • for 19" Touch Touch pen Undetachable pen for operation of the touch devices, mounting of the support on the control cabinet or directly on the PRO unit 5/132 Siemens ST 80 / ST PC · 2013 6AV7671-2BA00-0AA0 6AV7671-4BA00-0AA0 6AV7672-1CE00-0AA0 6AV7672-1JB00-0AA0 Connection cables for Standard, Extended and PRO versions • Video (VGA) - 3.0 m - 5.0 m 6AV7860-0AH30-0AA0 6AV7860-0AH50-0AA0 • Video (DVI-D) - 3.0 m - 5.0 m 6AV7860-0BH30-0AA0 6AV7860-0BH50-0AA0 • USB for optional touch screen - 3.0 m - 5.0 m 6AV7860-0CH30-0AA0 6AV7860-0CH50-0AA0 Connection cables for Extended and PRO versions • Cable set 10 m (DVI-D, CAT5 cable (USB), USB transmitter module) • Cable set 15 m (DVI-D, CAT5 cable (USB), USB transmitter module) • Cable set 20 m (DVI-D, CAT5 cable (USB), USB transmitter module) • Cable set 30 m (DVI-D, CAT5 cable (USB), USB transmitter module) 5 6AV7861-1KB10-1AA0 6AV7861-2KB10-1AA0 6AV7861-5TB10-1BA0 6AV7861-6TB10-1BA0 6AV7860-1EX21-0AA1 6AV7860-1EX21-5AA1 6AV7860-1EX22-0AA1 6AV7860-1EX23-0AA1 © Siemens AG 2013 PC-based Automation Industrial monitors and thin clients SIMATIC Flat Panels ■ Dimensional drawings All dimensions in mm. For mounting cut-out see technical specifications. 400 310 H 10.5 D W W+1 (cutout) Installation cutout for Flat Panel G_ST80_XX_00350 Flat Panel PRO 15" Touch Front dimensions Installation cutout W H W+1 H+1 D 12" 400 310 368 290 51 15" 483 310 450 290 55 19" 483 400 450 380 57 483 SIMATIC FLAT PANEL 5 400 Touch devices 67.85 G_ST80_XX_00238 H+1 (cutout) 90.85 G_ST80_XX_00371 82 105 Flat Panel PRO 19" Touch ■ More information Additional information is available on the Internet at: http://www.siemens.com/industrial-lcd Note: Examples are: • SIMATIC SCD monitor 1900 for portrait operation • SIMATIC Flat Panels with 6" and 10" Touch Do you need a specific modification or extension to the products described here? Then refer to "Customized Automation". There you will find information about additional and generally available sector-specific products as well as options for customer-specific modification and adaptation. Siemens ST 80 / ST PC · 2013 5/133 © Siemens AG 2013 PC-based Automation Industrial monitors and thin clients SCD desk monitors SCD 19101 ■ Overview ■ Technical specifications 19" monitors SCD 19101-D/-DT General features Supply voltage • Supply voltage • Frequency/power consumption • Line side switch • Representation The SCD 19101 D/DT monitors are LCD desktop monitors for use in industry. Type of operator control: • Simple display devices • Panels with touch control Display • Display version • Screen diagonals • visible area (HxV) in mm • Viewing angle • Pixel pitch • Optimum resolution (in pixels) • Refresh rate • Line frequency • Brightness/contrast (typical) • Number of colors • MTBF of backlit display (up to 50%, at 25 °C) Type of operation • Function keys • Membrane keyboard & piezo mouse • Touch screen Degree of protection • Degree of protection according to EN 60529 110/230 V AC 47 - 63 Hz/30 VA No Full screen 19" TFT 19" 359 x 287 170° x 170° 0.28 x 0.28 1280 x 1024 30 - 100 Hz 50 - 97 KHz 270 cd/m2/400:1 16 million 50,000 h No No Optional IP20 Ambient conditions • Temperature - Ambient temperature during operation Interfaces • Interface design, analog video signal (VGA) • PS/2 interfaces for keyboard & mouse • Serial interface for touch screen 5 Dimensions • External dimensions (W x H x D) in mm • Installation cutout/depth (W x H x D) in mm • Weight in kg ■ Ordering data 5/134 Siemens ST 80 / ST PC · 2013 0 to +40°C Yes No Optional/serial 465 x 444 x 91 (stand depth 240) 465 x 444 x 91 (stand depth 240) 7 Order No. 19" LCD monitors SCD 19101-D, desktop model 6GF6220-1DA01 19" Touch LCD monitors SCD 19101-DT, desktop model 6GF6220-1DB01 © Siemens AG 2013 PC-based Automation Industrial monitors and thin clients SCD desk monitors SCD 19101 ■ Dimensional drawings All dimensions in mm. For mounting cut-out see technical specifications. 465 15" 380 G_ST80_XX_00031 240 287.6 393 444 47 20 393 91 5" 160 SCD 19101-D/DT ■ More information Additional information is available in the Internet under: http://www.siemens.com/industrial-lcd 5 Siemens ST 80 / ST PC · 2013 5/135 © Siemens AG 2013 PC-based Automation Industrial monitors and thin clients SCD monitors 1900 ■ Overview The SIMATIC HMI SCD 1900 is a rugged, industry-standard PC monitor. It is used as an operator control unit in all types of industrial and standard PC, including for portrait mounting. Standard interfaces permit a wide range of possible applications. Built-in versions: • Built-in unit (for control cabinets, control desks, and gantries) • Built-in portrait for portrait mounting (for control cabinets, control desks and gantries) • 19" built-in units (for 19" racks) Type of operator control: • Panels with touch control ■ Technical specifications 6AV7862-2TA00-1AA0 SCD 1900 5 General information Short designation Flat Panel 19" Touch Display Screen diagonal 19 in visible area (HxV) in mm 255 x 408 Viewing angle 160° x 170° Type TFT widescreen display, LED backlighting On Screen Display (OSD) configuration Yes Number of colors (bit levels) 24 bit Backlighting • MTBF backlighting (up to 50%, at 25 °C) 50 000 h Installation type/mounting Rack mounting possible Yes Built-in unit Yes VESA mounting No Supply voltage Type of actuation • AC • DC DC Yes; With an external power supply unit Yes permissible range, lower limit (DC) 21.6 V permissible range, upper limit (DC) 26.4 V 5/136 Siemens ST 80 / ST PC · 2013 6AV7862-2TA00-1AA0 SCD 1900 Interfaces Video interfaces • VGA • DVI-D Yes Yes Touch interfaces • USB Yes Degree and class of protection IP65 at front Yes IP20 rear Yes Standards, approvals, certificates CE Yes; Industry CSA No UL Yes cULus Yes Ambient conditions Storage/transport temperature • Min. • max. -20 °C 60 °C Shock testing • Shock loading in operation • Shock load during transport/storage 10 g 10 g Mechanics/material Type of housing (front) • Aluminum Yes Weight Weight without packaging 6 kg © Siemens AG 2013 PC-based Automation Industrial monitors and thin clients SCD monitors 1900 ■ Ordering data Order No. SCD monitor 1900 6AV7862-2TA00-1AA0 Portrait SCD monitor 1900 6AV7466-2TA17-1AA0 ■ Dimensional drawings All dimensions in mm. For mounting cut-out see technical specifications. Accessories USB cable for connecting the touch screen • 3.0 m • 5.0 m 6AV7860-0CH30-0AA0 6AV7860-0CH50-0AA0 6AV7860-2AD06-0AA0 483 W+1 (cutout) H+1 (cutout) External power supply for SCD 1900 100-230 V AC, 50-60 Hz; incl. mounting accessories for optional installation at the device. G_ST80_XX_00239 6AV7860-0AH30-0AA0 6AV7860-0AH50-0AA0 6AV7860-0BH30-0AA0 6AV7860-0BH50-0AA0 310 S Cable for connecting to the graphics interface of the PC • VGA cable 3.0 m • VGA cable 5.0 m • DVI-D cable, 3.0 m • DVI-D cable, 5.0 m SCD 1900 5 Siemens ST 80 / ST PC · 2013 5/137 © Siemens AG 2013 PC-based Automation Industrial monitors and thin clients SCD monitors 1900 ■ Dimensional drawings (continued) 18.5 18.5 1 63 23.3 105.1 114.4 Power 24V... 67 DVI 43 VGA 11 USB-Touch 136.5 310 133.6 57.7 6 1 483 1 5 with installed optional DC power supply unit All dimensions in mm. For mounting cut-out see technical specifications. ■ More information Additional information is available in the Internet under: http://www.siemens.com/industrial-lcd 5/138 Siemens ST 80 / ST PC · 2013 81 G_ST80_XX_00429 11 62.5 1 © Siemens AG 2013 PC-based Automation Industrial monitors and thin clients SIMATIC Industrial Thin Client ■ Overview SIMATIC ITC Industrial Thin Clients are powerful operating units for flexible use in distributed visualization applications. All devices are equipped with high-resolution, brilliant widescreen displays, and due to the diverse communication protocols they can be used both for challenging machine-level operator control & monitoring and for the connection to control systems, e.g. in the SCADA environment. They can be used as (additional) operator stations on a SIMATIC Industrial PC, Panel PC, or server, and on a SIMATIC Panel. The following installation versions are available: • SIMATIC ITC1200 – 12" Touch • SIMATIC ITC1500 – 15" Touch • SIMATIC ITC1900 – 19" Touch • SIMATIC ITC2200 – 22" Touch In addition to these devices, we continue to offer the SIMATIC Thin Client 10", SIMATIC Thin Client 15", and SIMATIC Thin Client PRO 15" for solutions in 4:3 format. These differ technically from the SIMATIC ITC. For more details, refer to the SIMATIC Thin Client chapter. The SIMATIC HMI Thin Client Ex is available for hazardous areas. This device differs technically from the devices mentioned above. For more details, refer to the SIMATIC Thin Client EX chapter. ■ Technical specifications 6AV6 646-1AA22-0AX0 6AV6 646-1AB22-0AX0 6AV6 646-1AC22-0AX0 6AV6 646-1AD22-0AX0 Display Screen diagonal 12.1 in 15.4 in 18.5 in 21.5 in Display width 261.1 mm 331.2 mm 409.8 mm 495.6 mm Display height 163.2 mm 207 mm 230.4 mm 292.2 mm Type TFT widescreen display, LED backlighting TFT widescreen display, LED backlighting TFT widescreen display, LED backlighting TFT widescreen display, LED backlighting Number of colors 16 777 200 16 777 200 16 777 200 16 777 200 Resolution (pixels) • Horizontal image resolution • Vertical image resolution 1 280 800 1 280 800 1 366 768 1 920 1 080 General features • PDF reader Yes Yes Yes Yes Backlighting • Backlighting (type) • Dimmable backlight LED, dimmable Yes; 5-100 % LED, dimmable Yes; 5-100 % LED, dimmable Yes; 5-100 % LED, dimmable Yes; 5-100 % Control elements Mouse/cursor control • USB Yes Yes Yes Yes Keyboard fonts • external keyboard - USB Yes Yes Yes Yes Touch operation • Design as touch screen - Analog, resistive • Touch keyboard Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Installation type/mounting Built-in unit Yes Yes Yes Yes Siemens ST 80 / ST PC · 2013 5/139 5 © Siemens AG 2013 PC-based Automation Industrial monitors and thin clients SIMATIC Industrial Thin Client ■ Technical specifications (continued) 5 6AV6 646-1AA22-0AX0 6AV6 646-1AB22-0AX0 6AV6 646-1AC22-0AX0 6AV6 646-1AD22-0AX0 Supply voltage Type of actuation 24 V DC 24 V DC 24 V DC 24 V DC permissible range, lower limit (DC) 19.2 V 19.2 V 19.2 V 19.2 V permissible range, upper limit (DC) 28.8 V 28.8 V 28.8 V 28.8 V Input current Current consumption 1.2 A 1.5 A 1.3 A 2.2 A Inrush current A²s 0.5 A²·s 0.5 A²·s 0.5 A²·s 0.5 A²·s Interfaces USB on the rear 2 2 2 2 USB at the front 0 0 0 0 Industrial Ethernet • Transmission rate, max. • Number of industrial Ethernet interfaces 1 000 Mbit/s 1 1 000 Mbit/s 1 1 000 Mbit/s 1 1 000 Mbit/s 1 Protocols Protocols (Ethernet) • TCP/IP • DHCP • SNMP • DCP • LLDP Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes WEB characteristics • HTTP • HTML • XML • CSS • JavaScript Yes Yes; HTML5 Yes Yes Yes Yes Yes; HTML5 Yes Yes Yes Yes Yes; HTML5 Yes Yes Yes Yes Yes; HTML5 Yes Yes Yes Protocols (terminal link) • Sm@rtServer • RDP • VNC viewer • Citrix • SINUMERIK Yes Yes Yes No Yes Yes Yes Yes No Yes Yes Yes Yes No Yes Yes Yes Yes No No Protocols PROFINET IO Device • Services - PROFIenergy No No No No Degree and class of protection IP65 at front Yes Yes Yes Yes IP20 rear Yes Yes Yes Yes Standards, approvals, certificates CE Yes Yes Yes Yes KC approval Yes Yes Yes Yes cULus Yes Yes Yes Yes C-TICK Yes Yes Yes Yes Use in hazardous areas • cULus Class I Zone 1 • cULus Class I Zone 2, Division 2 • FM Class I Division 2 No Yes; Available soon Yes; Available soon No Yes; Available soon Yes; Available soon No Yes; Available soon Yes; Available soon No Yes; Available soon Yes; Available soon 5/140 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation Industrial monitors and thin clients SIMATIC Industrial Thin Client ■ Technical specifications (continued) 6AV6 646-1AA22-0AX0 6AV6 646-1AB22-0AX0 6AV6 646-1AC22-0AX0 6AV6 646-1AD22-0AX0 Ambient conditions Min. ambient temperature 0 °C 0 °C 0 °C 0 °C Max. ambient temperature 50 °C 50 °C 45 °C 45 °C Storage/transport temperature • Min. • max. -20 °C 60 °C -20 °C 60 °C -20 °C 60 °C -20 °C 60 °C Relative humidity • Relative humidity during operation 90 % 90 % 90 % 90 % Software Web browser Yes Yes Yes Yes Yes Yes; With Remote Configuration Center (RCC) as of V2.0 Yes Yes; With Remote Configuration Center (RCC) as of V2.0 Yes Yes; With Remote Configuration Center (RCC) as of V2.0 Yes Yes; With Remote Configuration Center (RCC) as of V2.0 Yes Yes Yes Yes Yes Yes Yes Yes Yes; USB storage media can be connected Yes; USB storage media can be connected Yes; USB storage media can be connected Yes; USB storage media can be connected Mechanics/material Type of housing (front) • Aluminum Yes Yes Yes Yes Dimensions External dimensions (W x H x D) • Width • Height 330 mm 241 mm 415 mm 310 mm 483 mm 337 mm 560 mm 380 mm Mounting cutout (W x H x D) • Width • Height • Depth 310 mm 221 mm 82 mm 396 mm 291 mm 75 mm 465 mm 319 mm 75 mm 542 mm 362 mm 75 mm Weight Weight without packaging 3.4 kg 5.2 kg 6.5 kg 7.1 kg Weight incl. packaging 4.1 kg 5.7 kg 7.1 kg 7.8 kg Configuration • On-board • Remote administration Languages Online languages • German • English I/O I/O devices • USB memory Siemens ST 80 / ST PC · 2013 5 5/141 © Siemens AG 2013 PC-based Automation Industrial monitors and thin clients SIMATIC Industrial Thin Client ■ Ordering data Industrial Thin Client • SIMATIC ITC1200 12" Touch device • SIMATIC ITC1500 15" Touch device • SIMATIC ITC1900 19" Touch device • SIMATIC ITC2200 22" Touch device 6AV6646-1AA22-0AX0 ■ Dimensional drawings All dimensions in mm. For mounting cut-out see technical specifications. 6AV6646-1AB22-0AX0 6AV6646-1AC22-0AX0 6AV6646-1AD22-0AX0 See HMI accessories, from page 2/96 H Accessories Order No. D W 6.5 G_ST80_XX_00522 H+1 W+1 Mounting dimensions Industrial Thin Client 5 Faceplate Dimensions, in mm Mounting Cutout, in mm W H W+1 H+1 D ITC1200 330 241 310 221 82 ITC1500 415 310 396 291 75 ITC1900 483 337 465 319 75 ITC2200 560 380 542 362 75 ■ More information Additional information is available on the Internet at: http://www.siemens.com/simatic-itc 5/142 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation Industrial monitors and thin clients SIMATIC Thin Client ■ Overview SIMATIC Thin Clients are very economical operator panels which can be used flexibly in various distributed applications. They can be used as (additional) operator stations on a SIMATIC industrial PC or also on a SIMATIC Panel. The following versions are available: • The rack-mounting versions SIMATIC Thin Client 10" Touch and SIMATIC Thin Client 15" Touch • The support arm version SIMATIC Thin Client PRO 15" Touch with a rugged and very compact aluminum enclosure which is completely IP65 protected The new high-performance SIMATIC ITC Industrial Thin Clients with high-resolution touch displays in widescreen format from 12" to 22" are available for demanding terminal applications. There are technical differences to the SIMATIC Thin Client. For more information, see SIMATIC Industrial Thin Client. The SIMATIC HMI Thin Client Ex is available for hazardous areas. This device differs technically from the devices mentioned above. ■ Technical specifications 6AV6646-0AA21-2AX0 10" Touch 6AV6646-0AB21-2AX0 15" Touch Display Size 10.4" 15.1" Display type TFT, 65536 colors TFT, 65536 colors Resolution (pixels) • Resolution (WxH in pixel) 640 x 480 1024 x 768 Backlighting • MTBF backlighting (at 25 °C) about 50000 hours about 50000 hours Control elements Control elements Touch screen Touch screen USB / USB USB / USB Touch operation • Touch screen Analog, resistive Analog, resistive Supply voltage Supply voltage 24 V DC 24 V DC Processor Processor ARM, 266 MHz ARM, 266 MHz Memory Type Flash / RAM Flash / RAM Interfaces Interfaces 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) USB port 1 x USB 1 x USB Industrial Ethernet • Industrial Ethernet interface 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) Connection for mouse/keyboard/ barcode reader Siemens ST 80 / ST PC · 2013 5 5/143 © Siemens AG 2013 PC-based Automation Industrial monitors and thin clients SIMATIC Thin Client ■ Technical specifications (continued) 6AV6646-0AA21-2AX0 10" Touch 6AV6646-0AB21-2AX0 15" Touch Protocols WEB characteristics • HTTP • HTML • XML • CSS • JavaScript Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Protocols (terminal link) • Sm@rtServer • RDP Yes Yes Yes Yes EMC Emission of radio interference acc. to EN 55 011 • Emission of radio interferences acc. to EN 55 011 (limit class A) Yes; EN 61000-6-4, interference emission: Intended for use in industrial areas. Degree and class of protection Front IP54, NEMA 12, (when installed) IP54, NEMA 12, (when installed) Rear IP20 IP20 CE, cULus, C-TICK, NEMA 12 (when installed: IP54, enclosure type 12; optional IP65, enclosure type 4X/type 12 (6AV6671-6AP00-0AX0)) CE, cULus, C-TICK, NEMA 12 (when installed: IP54, enclosure type 12; optional IP65, enclosure type 4X/type 12 (6AV6671-6AP00-0AX0)) EMC The product is designed for use in industrial environments. When used in residential areas, the emission of radio interference according to limit class B of EN 55011 must be ensured. For further information please refer to the user documentation. The product is designed for use in industrial environments. When used in residential areas, the emission of radio interference according to limit class B of EN 55011 must be ensured. For further information please refer to the user documentation. Suitable for safety functions No No Ambient conditions maximum permissible angle of inclination without external ventilation +/- 35 ° +/- 35 ° Storage/transport temperature • Transport, storage -20 °C to +60 °C -20 °C to +60 °C Relative humidity • max. relative humidity 85 %; (Storage) Dimensions Front of enclosure (W x H) 325 mm x 263 mm 400 mm x 310 mm Weight Weight 2.2 kg 3.6 kg Standards, approvals, certificates Certifications 5 ■ Ordering data SIMATIC Thin Client • 10" Touch device • 15" Touch device Order No. 6AV6646-0AA21-2AX0 6AV6646-0AB21-2AX0 Starter kits SIMATIC Thin Client with Sm@rtAccess (License to operate SmartAccess on the server) • Touch device 10" with Sm@rtAccess license (panels) • Touch device 15" with Sm@rtAccess license (panels) • Touch device 15"PRO with Sm@rtAccess license (panels) • Touch device 10" with Sm@rtAccess license for WinCC flexible 2008 Runtime • Touch device 15" with Sm@rtAccess license for WinCC flexible 2008 Runtime • Touch device 15" PRO with Sm@rtAccess license for WinCC flexible 2008 Runtime 5/144 Order No. Option packages 6AV6653-6AA01-2AA0 6AV6653-6BA01-2AA0 6AV6653-6CA01-2AA0 6AV6653-6DA01-2AA0 6AV6653-6EA01-2AA0 6AV6653-6FA01-2AA0 Siemens ST 80 / ST PC · 2013 IP65 set (upgrade from IP54 to IP65) 6AV6671-6AP00-0AX0 Accessories See HMI accessories, from page 2/96 © Siemens AG 2013 PC-based Automation Industrial monitors and thin clients SIMATIC Thin Client ■ Dimensional drawings All dimensions in mm. Tolerance ± 1 mm. 59.9 6.2 400 59.9 6.2 310 63.21 288 113.59 247 106.71 275 113.59 335 30 SIMATIC Thin Client 10" Touch 366 232.49 G_ST80_XX_00306 232.49 30 G_ST80_XX_00305 309 SIMATIC Thin Client 15" Touch ■ More information Additional information is available in the Internet under: http://www.siemens.com/simatic-thin-client 5 Siemens ST 80 / ST PC · 2013 5/145 © Siemens AG 2013 PC-based Automation RMOS3 real-time operating system RMOS3 real-time operating system ■ Overview SICOMP RMOS3 RMOS3-TCP/IP V3.0 RMOS3 is a real-time and multitasking-capable operating system. In addition to real-time capability, which ensures fast response times, deterministic behavior is also an important feature. This guarantees response times within a short time interval. The RMOS3-TCP/IP V3.0 software package offers the application developer a wide range of options for implementing TCP/ UDP-based communication tasks running under the real-time operating system RMOS3, V3.40 or higher. Rugged operating systems guarantee reliable behavior even under exceptional circumstances. RMOS3 has been optimized for use in embedded applications. In harsh environments, the rugged memory cards or CompactFlash memories can be used instead of hard disks. In addition, RMOS3 is suitable for operation with or without an operator. RMOS3 V3.50 Real-Time Operating System With the RMOS3 V3.50, Intel Core i processors with up to 2 cores/4 threads are now also supported. The "Symmetric Multicore Processing" (SMP) mode makes it possible to implement complex applications that are simultaneously processed on multiple processor cores. RMOS3 V3.50 ensures that the cores are symmetrically utilized so that a performance increase of up to 100% can be achieved on the SIMATIC IPC with 2 processors. 5 Apart from the usual UDP and TCP protocols for application development, the new version of RMOS3-TCP/IP not only provides Address Resolution Protocol (ARP), Multicast and ICMP services (Ping), but also client services for the DHCP (Dynamic Host Configuration Protocol), DNS (Domain Name System), NTP (Network Time Protocol) and SMTP (Simple Mail Transfer Protocol). Together with the FTP programming interface and the Web server with process data connection, the programmer obtains numerous programming interfaces for even greater flexibility in communication. RMOS3-GRAPHX V1.0 With the RMOS3-GRAPHX product, window-based, graphical user interfaces can be implemented with the RMOS3 real-time operating system Version V3.30 or higher. The new RMOS3 real-time operating system is characterized by increased security thanks to memory protection, minimum interrupt response times and fast hard disk access. For SIMATIC IPCs, automation solutions based on C/C++ with demands for hard real time, deterministic response and high performance can now be created more easily, conveniently and with greater stability. Extensive graphical libraries increase the user-friendliness of the system and support cost savings due to centralization of the control and operation on a CPU. RMOS3-GNU V3.0 BSP SIMATIC IPC V4.0 for RMOS3 The RMOS3-GNU software package uses generally available Linux tools with which users can easily create real-time applications for RMOS3 on the SIMATIC IPC. The Board Support Package BSP SIMATIC IPC V4.0 for RMOS3 is a software package for supporting all interfaces (e.g. PROFINET onboard) and other onboard functions (e.g. battery monitoring, watchdog) for the following industrial PCs: SIMATIC IPC227D, SIMATIC IPC427C, SIMATIC IPC627C, SIMATIC IPC 827C, SIMATIC IPC647C and SIMATIC IPC847C. The GNU-based software tools for Windows XP/Vista/Windows 7 computers comprise the assemblers, C/C++ compilers, linkers and debuggers familiar in the Linux environment as well as the Eclipse development interface. The integrated cross debugger is useful for commissioning the customer application since the development and target system can be connected via TCP/IP. C/C++ header files and libraries are available for applications which use RMOS3 Version 3.30 or higher. 5/146 Siemens ST 80 / ST PC · 2013 With a Graphical User Interface (GUI), familiar from Windows, window displays can be implemented with the familiar command elements in the form of buttons, toolbars, scrollbars, selection lists and symbols as well as dialog boxes for prompts or inputs. © Siemens AG 2013 PC-based Automation RMOS3 real-time operating system RMOS3 V3.50 real-time operating system ■ Overview RMOS3 is the real-time and multitasking-capable operating system from Siemens for implementing your automation solution with the programming languages C and C++. In mechanical engineering or in the manufacture of machine tools RMOS3 is used in test beds, packaging or printing machines where high response times in conjunction with open and closed-loop control tasks are required. The new RMOS3 real-time operating system is characterized by increased security thanks to memory protection, minimum interrupt response times and fast hard disk access. Furthermore, with the RMOS3 V3.50 version, Intel Core i processors with up to 2 cores/4 threads are now also supported. The "Symmetric Multicore Processing" (SMP) mode makes it possible to implement complex applications that are simultaneously processed on multiple processor cores. RMOS3 V3.50 ensures that the cores are symmetrically utilized so that a performance increase of up to 100% can be achieved on the SIMATIC IPC with 2 cores. For SIMATIC IPC, automation solutions based on C/C++ with demands for hard real time, deterministic response and high performance can now be created more easily, conveniently and with greater stability. RMOS3 has been optimized for use on PC platforms in embedded systems and fulfills industrial requirements with respect to: • Real-time and multitasking capability • Deterministic features • Ruggedness • Scalability/memory requirements • Operation with or without an operator • Modern development tools • Quality assurance • Warranty conditions • Service & Support ■ Technical specifications System requirements for the development system • PC with Windows XP, Windows Vista or Windows 7 Required software components: • RMOS3 development environment as of RMOS3 V3.40 • RMOS3-GNU as of V2.1, compiler and development interface • Board Support Packages (optional, module-specific expansion packages) System requirements for target system • SIMATIC IPC427C • SIMATIC Box PC 627B/827B, IPC627C • SIMATIC Rack PC 647B/847B, IPC647C, IPC847C Required software components: • RMOS3 V3.50 runtime environment (RMOS nucleus and service programs) • Board Support Packages (optional, module-specific drivers) Product structure, listed acc. to development and runtime licenses Product name Description RMOS3 V3.50 EL Single license for RMOS3 development environment incl. a RMOS3 runtime license comprising RMOS3 V3.50 EL Update • Sources and libraries for application creation • RMOS3 runtime environment incl. loadable programs and TCP/IP stack and 10/100 Mbit/s LAN drivers • Configurable RMOS3 Nucleus for the Use on SIMATIC IPCs • Examples and documentation Single license for the GNU development tools incl. • Compiler, linker, debugger and Eclipse IDE • Special RMOS3 libraries for application creation • Example projects and documentation RMOS3-GNU V3.0 EL RMOS3-GNU V3.0 EL Update BSP-SIMATIC IPC 4.0 EL 1) BSP SIMATIC IPC V4.0 EL Update 1) RMOS3-TCP/IP V3.0 EL 1) incl. German documentation RMOS3-TCP/IP V3.0 EL Update 1) RMOS3-PC IO V2.0 1) • Single license for IPC227D, IPC427C, IPC627C, IPC827C, IPC647C, IPC847C incl. runtime license for BSP (no runtime license for RMOS3 V3.50): • Configurable nucleus • Driver for USB, LAN, PROFINET IO, PROFIBUS DP, BasicCAN • GNU example projects and documentation Master license for TCP/IP communication • Application development with socket interface • Programming interface for FTP Free download as programming example with programming interface for access to PC I/O modules Optional Board Support Packages (BSP) Siemens ST 80 / ST PC · 2013 5/147 5 © Siemens AG 2013 PC-based Automation RMOS3 real-time operating system RMOS3 V3.50 real-time operating system ■ Technical specifications (continued) Product structure – Runtime licenses Product name Description RMOS3 V3.50 RT Single RMOS3 V3.50 runtime license RMOS3-TCP/IP V3.x RT 1) • Single RMOS3 TCP/IP runtime license • Required for application programs with socket interface RMOS3-CANopen168 1) Single runtime license with software package when the CPCI-COM168 module is used in networks with CANopen BSP SIMATIC IPC RT V4.x 1) Single runtime license for BSP Supported boot media • Disk • Hard disk • IDE flash disk • LAN (on request) Available drivers for RMOS3 V3.50 The drivers described below are currently available for RMOS3 V3.50 • PS2 keyboard Keyboard • USB keyboard 1) Serial, parallel • Universal I/O driver (BYT driver) for character-oriented I/O devices • COM driver for 3964(R) protocol Transmission mode and baud rate configurable • EGA (text mode) Graphics • Semi-graphical interface (function library on request) 5 • RMOS3-GRAPHX (graphics library for pixel graphics window displays) 1) 10/100/1000 Mbit/s LAN driver: Ethernet • IPC227D, IPC427C, IPC627C, IPC827C, IPC647C, IPC847C • Filter functionality, configurable transfer rates and transfer modes USB 1) • Optional USB driver for USB 1.1 protocol and USB 2.0 protocol • Support for keyboard, mouse, hub, memory stick and CD-ROM (on request) • Module driver for operating the CP 1616-compatible PROFINET components (CP 1616, CP 1604, SIMATIC IPC with PROFINET onboard) PROFINET IO • Supports the ERTEC 400 controller, RT and IRT, IO Controller and/or IO Device PROFIBUS DP 1) • Module driver and programming interface for SIMATIC PC with PROFIBUS onboard, CP5611 compatible, DPV0 master and/or slave CAN 1) • BasicCAN driver for connection to CAN bus • Supports the SJA1000 CAN controller on SIMATIC IPC427C 1) Optional Board Support Packages (BSP) 5/148 Siemens ST 80 / ST PC · 2013 ■ Ordering data Order No. RMOS3 V3.50 EL Single license for RMOS3 development environment incl. a RMOS3 runtime license 6AR1405-0EA00-1AA4 RMOS3 V3.50 EL Update Update from V3.40 to V3.50. Single license for RMOS3 development environment incl. a RMOS3 runtime license 6AR1405-0EA50-1AA4 RMOS3 V3.50 RT Single RMOS3 V3.50 runtime license 6AR1403-0DA3 © Siemens AG 2013 PC-based Automation RMOS3 real-time operating system RMOS3-GNU V3.0 ■ Overview RMOS3-GNU V3.0 is a software package that supports development and testing of applications for the real-time operating system RMOS3 (Version 3.40 and higher). It builds on a GNU-based tool chain that is well-known and widely implemented in the Linux environment and contains the expansions required for RMOS3. RMOS3-GNU V3.0 replaces the existing RMOS3-GNU V2.x product. An update from RMOS3-GNU V2.x to Version V3.0 is available. RMOS3-GNU V3.0 contains the following new functions: • Up-to-date versions of the GNU tool chain, e.g. C/C++ compiler V3.4.1 • Updated versions of Eclipse V3.4 and CDT plug-in V5.0. • New Eclipse "terminal" plug-in for remote operation of the target system • New Eclipse "profiling" plug-in for determining the system load and the task activity on the target system • Extended Eclipse "remote launcher" plug-in for testing the applications on Privilege Level 0 or alternatively on Privilege Level 1 ■ Technical specifications System requirements: Development system • Windows XP, Windows Vista, or Windows 7 • Java Runtime Environment, Version 1.5 and higher (only necessary when using Eclipse IDE) • RMOS3 development environment RMOS3 Version 3.40 (incl. software fix RMOS3 V3.40.02) or RMOS3 V3.50 (incl. software fix RMOS3 V3.50.04) System requirements: Target system • RMOS3 version 3.40.02 and higher or version 3.50.04 (configurable nucleus V3.30.06 R01) Licenses The GNU-based tool chain is subject to the GNU GENERAL PUBLIC LICENSE (GPL) or the GNU LESSER GENERAL PUBLIC LICENSE (LGPL). Please read the licensing rules supplied with the product. ■ Ordering data Order No. SICOMP RMOS3-GNU V3.0 EL Single license for the GNU development tools incl. compiler, linker, debugger and Eclipse IDE, special RMOS3 libraries for creating applications, project examples and documentation 6AR1405-0BA00-1CA0 SICOMP RMOS3-GNU V3.0 EL update Update V2.x to V3.0, development package, single license, CD-ROM, including description in German in PDF format 6AR1405-0BA50-1CA0 5 Siemens ST 80 / ST PC · 2013 5/149 © Siemens AG 2013 PC-based Automation RMOS3 real-time operating system RMOS3-TCP/IP V3.0 ■ Overview ■ Ordering data The RMOS3-TCP/IP V3.0 software package provides libraries for the quick and easy generation of TCP/IP, FTP and Web applications. In addition, the software package offers FTP and Telnet services for the exchange of files and for the remote maintenance of the RMOS3 system. New additions are the DHCP, DNS, NTP and SMTP services for even greater flexibility in communication. ■ Technical specifications System requirements for the development system • PC with Windows XP, Windows Vista or Windows 7 Required software components: • RMOS3 development environment as of RMOS3 V3.40 • RMOS3-GNU as of V2.1, compiler and development interface • Board support packages (optional, module-specific expansion packages) System requirements for target system • SIMATIC Microbox PC IPC427C • SIMATIC Box PC 627B/IPC627C • SIMATIC Box PC 827B • SIMATIC Rack PC 647B/IPC647C • SIMATIC Rack PC 847B/IPC847C Required software components: • RMOS3 V3.40 or higher runtime environment (RMOS nucleus and service programs) • Board support packages (optional, module-specific drivers) 5 5/150 Siemens ST 80 / ST PC · 2013 Order No. SICOMP RMOS3-TCP/IP V3.0 EL Development package, single license, TCP/IP software for RMOS3 V3.40 or higher, CD-ROM, including description in German in PDF format 6AR1403-0AN00-1BA0 SICOMP RMOS3-TCP/IP V3.0 EL, update from V2.3 to V3.0 Development package, single license, TCP/IP software for RMOS3 V3.40 or higher, CD-ROM, including description in German in PDF format 6AR1403-0AN50-1BA0 SICOMP RMOS3-TCP/IP V3.x Runtime license Runtime license for TCP/IP software V3.0 or higher for use with RMOS3 V3.40 or higher 6AR1403-0BN3 © Siemens AG 2013 PC-based Automation RMOS3 real-time operating system RMOS3-GRAPHX V1.0 ■ Overview RMOS3-GRAPHX V1.0 provides you with a comprehensive graphics package which enables you to expand your C/C++ based automation solution under SICOMP RMOS3 with a userfriendly graphics interface for operator control and monitoring. Use of the Qt-based graphics library of the Norwegian company Trolltech-Nokia (www.gt.nokia.com) allows window-based interfaces to be created with a "look and feel" and input facilities comparable to Windows. Real-time characteristics are maintained within the multi-tasking RMOS3 operating system environment. In combination with the widely used development tools GNU, Eclipse and the QT Designer from Trolltech-Nokia, convenient development tools are available to you for creating your real-time applications on approved SIMATIC IPC hardware. ■ Technical specifications System requirements for the development system • PC with Windows XP, Windows Vista or Windows 7 Required software components: • RMOS3 development enviroment RMOS3 V3.40 or higher or RMOS3 V3.30 including software fix RMOS3 V3.30.04 • RMOS3-GNU as of V2.1, compiler and development interface • For RMOS3-GNU V3.0 or higher, an update for RMOS3-GraphX V1.1 is offered via Customer Support: http://www.siemens.com/automation/support-request • RMOS3-GRAPHX V1.0, graphics package for creation of graphics interfaces for RMOS3 • Update RMOS3-GraphX V1.1 in connection with RMOS3-GNU V3.0 or higher is available via Customer Support: http://www.siemens.com/automation/support-request • Qt Desktop Light Edition for Windows from Trolltech-Nokia (www.gt.nokia.com) Optional: • Board support packages (optional, module-specific expansion packages) System requirements for target system • SIMATIC IPC Required software components: • RMOS3 V3.40 or higher runtime environment (RMOS nucleus and service programs) • RMOS3-GRAPHX V1.0 runtime license (graphics support, USB driver) Optional: • Board support packages (optional, module-specific drivers) ■ Ordering data 5 Order No. RMOS3-GRAPHX V1.0 EL Master license for graphic library for the creation of window-oriented interfaces of RMOS3 Version 3.30 and higher 6AR1403-0BG00-1AA0 Qt Desktop Light Edition Single Platform Windows development package Obtainable from Trolltech-Nokia, www.gt.nokia.com Qt Desktop Light Edition V4.1.4 for Windows, incl. Qt Designer Siemens ST 80 / ST PC · 2013 5/151 © Siemens AG 2013 PC-based Automation RMOS3 real-time operating system BSP SIMATIC IPC V4.0 for RMOS3 ■ Overview ■ Ordering data The Board Support Package BSP SIMATIC IPC V4.0 supports SIMATIC IPC devices of the C generation and the D generation starting with the NANOBOX PC IPC227D. The following SIMATIC IPCs can therefore now be operated along with their PROFINET onboard functionality, PROFIBUS, CAN, and hardware-based functions with the real time operating system RMOS3 V3.50 and higher: • IPC227D • IPC427C and IPC427D • IPC627C and IPC827C • IPC647C and IPC847C ■ Technical specifications System requirements for the development system • PC with Windows XP, Windows Vista or Windows 7 Required software components: • RMOS3 development environment as of RMOS3 V3.50 • RMOS3-GNU V3.0 and higher, compiler and development interface • Board Support Packages (optional, module-specific expansion packages) System requirements for target system • SIMATIC IPC227D • SIMATIC IPC427C and IPC427D • SIMATIC IPC627C and IPC827C • SIMATIC IPC647C and IPC847C 5 Required software components: • RMOS3 V3.50 or higher runtime environment (RMOS nucleus and service programs) • Board Support Packages (optional, module-specific drivers) 5/152 Siemens ST 80 / ST PC · 2013 BSP SIMATIC IPC V4.0 EL Order No. 6AR1403-0BC00-1DA0 Board Support Package for SIMATIC IPC227D, SIMATIC IPC427C, SIMATIC IPC627C, IPC827C, SIMATIC IPC647C, and IPC847C for use with the SICOMP RMOS3 operating system V3.50 and higher, development package, single license, runtime license, CD-ROM, including description in German in PDF format, RMOS3 runtime license V3.50 and higher not included. BSP SIMATIC IPC V4.0 EL Update 6AR1403-0BC50-1DA0 Update from BSP SIMATIC IPC V3.1 to BSP SIMATIC IPC V4.0 BSP Nanobox IPC V1.x RT Package 6AR1403-1DC3 License bundle comprising RMOS3 V3.50 RT, RMOS3-TCP/IP V3.x RT and BSP SIMATIC IPC V4.x RT runtime licenses for use with the Nanobox PC IPC227D. BSP SIMATIC IPC V4.x RT Runtime license for Board Support Package BSP SIMATIC IPC V4.0 EL for • SIMATIC IPC227D • SIMATIC IPC427C • SIMATIC IPC627C, IPC827C • SIMATIC IPC647C, IPC847C for use with the SICOMP RMOS3 operating system V3.50 and higher 6AR1403-0DC3 © Siemens AG 2013 PC-based Automation Expansion components and accessories Expansion components / accessories ■ Overview SIMATIC PCs offer users a wide range of designs and systems which perfectly match industrial applications and fulfill the high requirements in terms of ruggedness. These include e.g.: • Wide temperature of use up to 55 °C • High resistance to vibration/shock • Rugged housing design • Special degrees of protection up to IP65, NEMA 4 • High electromagnetic compatibility (EMC) • UL, CE industry certification • Integral industrial power supplies (NAMUR) • Easy-to-service design for rapid replacement of faulty components Increased system availability A graded concept is available for effective early detection of potential failures and minimization of actual downtimes. This consists of hardware and software expansion options specially developed for SIMATIC PCs with which the system availability can be individually increased depending on the safety requirements. The use pays off: Because the safety is significantly increased by components such as a second hard disk for additional data backup or the DiagMonitor for permanent self-diagnostics. The system availability options thus make a contribution to the significant minimization of the total costs (TCO) of the installation according to the motto: "Small effort, large effect". The following components are available: Hard disks options • Solid-state drive (SSD) • Second hard disk: The safety of the data stored on the hard disk is a cornerstone for system availability. - Simple and fast data backup of complete installation and user data in combination with the SIMATIC IPC Image & Partition Creator. - Following a faulty software installation or in the case of a hard disk defect, the system can be immediately put back into operation by booting the back-up disk. - Fast download of the last saved hard disk image to the working disk. Two hard disks are optionally available in a user-friendly swap frame for the Rack PC to permit fast and easy data backup. SIMATIC IPC CompactFlash/SIMATIC IPC CFast The application of PCs in industrial areas requires rugged systems to prevent or minimize production downtimes. SIMATIC IPCs have been developed precisely for this purpose. One way of improving the industrial suitability and system availability of SIMATIC IPCs even further is to use SIMATIC PC CompactFlash cards instead of hard disk drives. These are system-tested with the SIMATIC IPCs. SIMATIC PC CompactFlash is a hardware option that can be ordered via the relevant SIMATIC IPC configurator or separately as an accessory. The SIMATIC IPC CFast memory cards are readily replaceable mass storage units for SIMATIC IPC427D and IPC477D. They are connected via a SATA interface. As a result of the different interface, the SIMATIC IPC CFast memory cards are not compatible with the SIMATIC IPC CompactFlash memory cards. SIMATIC IPC USB FlashDrive • Mobile memory medium for SIMATIC IPC/PG • Fast data transfer (USB 2.0) and high memory capacity • Ultra-compact and rugged • Preinstalled SIMATIC IPC BIOS Manager SIMATIC IPC Service USB FlashDrive The SIMATIC IPC Service USB FlashDrive is the ideal tool for maintenance as well as saving and restoring of data. With the preinstalled SIMATIC IPC Image & Partition Creator and SIMATIC IPC BIOS Manager, the FlashDrive is immediately ready for use. Central I/O expansion PC IO The PC IO expansion comprises: • Basic module with encoder/counter functionality, PCI104 interface to the host system, and communication interfaces to the I/O modules • Digital and analog I/O modules that are managed by the basic module • Mechanical installation components Industrial USB Hub 4 (see HMI accessories, page 2/96) • The Industrial USB Hub 4 is essentially used as a USB hub for the connection of I/O devices to Multi Panels and Panel PCs with an integral USB interface • USB I/O devices can be connected to the panel and operated via the USB Hub 4 without opening the cabinet door • The Industrial Hub 4, in contrast to commercially available USB hubs, can be used in harsh industrial environments (IP65) SIMATIC Panel PC Remote Kit • Separation of computer unit and operator control unit • At a maximum distance of up to 30 m • Pure hardware solution, no need to install additional software • Maintaining the full Panel PC front functionality Siemens ST 80 / ST PC · 2013 5/153 5 © Siemens AG 2013 PC-based Automation Expansion components and accessories Expansion components / accessories ■ Overview (continued) SIMATIC IPC Image & Partition Creator • Software tool for preventive data backup of hard disk contents • High-speed restoring of system and data partitions with bit accuracy; user software and special installations are also backed up • Software tool for editing the hard disk partitioning ADDM Data Management SIMATIC IPC DiagMonitor • Diagnostic and alarm software for monitoring SIMATIC IPCs • Comprehensive monitoring of temperature, fans, hard disks (SMART, RAID, CF Card, SSD), watchdog • Operating hours counter for preventive maintenance • Integrated log functions, comprehensive text messages, online help (English/German) DC-UPS uninterruptible power supplies SIMATIC IPC Remote Manager Efficient remote maintenance and management of SIMATIC IPCs. With the SIMATIC IPC Remote Manager you can use functions of the Intel Active Management Technology (Intel AMT) for SIMATIC IPCs. Intel AMT is used for remote management of PCs. SIMATIC IPC BIOS Manager The SIMATIC IPC BIOS Manager is a software tool with which CMOS data from the BIOS configuration of a SIMATIC IPC can be edited. The tool is obtained by downloading it from the Internet using the Automation Value Card from Customer Support. 5 5/154 Siemens ST 80 / ST PC · 2013 With ADDM, you are completely in control of the SIMATIC and SINUMERIK controllers – around the clock and with any program version. This tool, indispensable in modern production systems, allows user-friendly backup, comparison and management of control data. The uninterruptible DC power supply with battery modules consists of DC UPS modules. The maintenance-free SITOP UPS500 with capacitors as energy stores are especially suitable for use at high ambient temperatures. A further advantage of these high-capacity double-layer capacitors is their shorter charging times. For flexible use, there is the SITOP UPS500S – 15 A basic unit in 2.5 kW and 5 kW versions. Up to 3 SITOP UPS501S expansion modules of 5 kW each can be connected in parallel to extend the backup times. The SITOP UPS500P IP65 version has capacitors for 5 or 10 kW and supplies up to 7 A output current. Input and output devices The SIMATIC IPC accessories encompass various input devices. © Siemens AG 2013 PC-based Automation Expansion components and accessories SIMATIC IPC CompactFlash ■ Overview Rugged systems are required when using PCs in industrial environments to ensure minimal production standstill times. SIMATIC IPCs have been developed precisely for this purpose. One possibility for enhancing the industrial compatibility and system availability of the SIMATIC IPC is to use SIMATIC IPC CompactFlash instead of hard disk drives. These have been system-tested with the respective SIMATIC IPC. SIMATIC IPC CompactFlash can be ordered as a hardware option through SIMATIC IPC Configurator or as an accessory. Depending on the application, cards are available with a storage capacity ranging from 2 GB to 16 GB. ■ Ordering data Order No. SIMATIC IPC CompactFlash • 2 GB • 4 GB • 8 GB • 16 GB 6ES7648-2BF02-0XF0 6ES7648-2BF02-0XG0 6ES7648-2BF02-0XH0 6ES7648-2BF02-0XJ0 SIMATIC IPC CFast • 2 GB • 4 GB • 8 GB • 16 GB 6ES7648-2BF10-0XF0 6ES7648-2BF10-0XG0 6ES7648-2BF10-0XH0 6ES7648-2BF10-0XJ0 The SIMATIC IPC CFast memory cards are readily replaceable mass storage units for SIMATIC IPC427D and IPC477D. They are connected via a SATA interface. As a result of the different interface, the SIMATIC IPC CFast memory cards are not compatible with the SIMATIC IPC CompactFlash memory cards. SIMATIC IPC USB FlashDrive ■ Overview ■ Technical specifications SIMATIC IPC USB FlashDrive SIMATIC IPC Service USB FlashDrive The SIMATIC IPC USB FlashDrive is the ideal mobile storage medium for industrial applications. Thanks to the rugged and ultra-compact construction in a metal enclosure, fast data transfer (USB 2.0) and the high memory capacity of 8 GB, the USB FlashDrive is ideally suited for use in industrial applications. It replaces diskettes, CD and DVD read/write media as data memory. Thanks to its high access speed, it is also ideal for tools that are not to be installed on the computer ("portable apps"). In addition, it can be set up ready to boot using SIMATIC PC BIOS-Manager. There is an option of expanding the USB FlashDrive set up in this way into a "tool stick" using SIMATIC IPC Image & Partition Creator. The SIMATIC IPC SERVICE USB FlashDrive is the perfect tool for backup and restoring. With the pre-installed SIMATIC IPC Image & Partition Creator V3.1, it is immediately ready to use. Supported operating systems Windows 2000/XP/Vista/Windows 7/ Windows Server 2003/2008 Capacity 8 GB Approvals CE Industry Temperature • During operation • Storage +5 ... +55 °C -40 ... +70 °C Device dimensions (L x W x H) in mm 59.1 x 16.7 x 7 Weight, approx. 12 g ■ Ordering data 5 Order No. SIMATIC IPC USB FlashDrive 8 GB (SLC), USB 2.0, metal enclosure, boot capability, SIMATIC IPC BIOS Manager V3.2 preinstalled for SIMATIC IPC: Rack PC, Box PC, Panel PC and for SIMATIC PG 6ES7648-0DC50-0AA0 SIMATIC IPC Service USB FlashDrive 8 GB (SLC), USB 2.0, metal enclosure, boot capability, SIMATIC IPC Image & Partition Creator V3.2 and SIMATIC IPC BIOS Manager V3.2 (Win PE) preinstalled, including CD 6AV7672-8JD01-0AA0 Siemens ST 80 / ST PC · 2013 5/155 © Siemens AG 2013 PC-based Automation Expansion components and accessories PC I/O ■ Overview The PC IO expansion extends the rugged use of the SIMATIC HMI IPC427C at the machine level. You can find further information under Industrial PC -> SIMATIC PC -> SIMATIC Box PC. The I/O expansion enables and supplements the use of the SIMATIC HMI IPC427C with: • Extremely compact dimensions (262 mm wide, 134 mm high, depth from 47 mm) • High system availability (rugged and maintenance-free, since without rotating parts, for example) • Maximum flexibility The PC IO expansion comprises: • Base module with encoder/counter functionality, PCI104 interface to the HOST system and communication interfaces to the I/O modules • Digital and analog I/O modules that are managed by the basic module • Mechanical installation components A selection guide with material list for your requirements can be found at: http://www.siemens.com/simatic-pc/pc-io-selection 5 Module Description PC IO Base 400 (base module) • PCI104 interface to host • 4 encoder inputs, can also be used as counters if required • 4 digital inputs • Management of encoder inputs and associated counters and up to four I/O modules over separate communication interfaces • Power supply distribution for 4 encoders PC IO MOD Digital 010 (digital I/O module 0) • 24 binary 24 V inputs • 16 binary 24 V outputs PC IO MOD Analog 020 (analog I/O module 0) • 8 analog inputs, 12 bits, 0 to 5 V, 0 to 10 V ±5 V, ±10 V • 8 analog outputs, 16 bits, ±10V • 4 Pt100 connections, 2-wire PC IO KIT 040 (encoder expansion rack) For expanding a SIMATIC Microbox PC 420/427B/IPC427C. Connection unit for: • 4 encoder inputs • 4 digital inputs • Encoder voltage supply PC IO KIT 030 (I/O expansion rack) Expansion rack to hold • max. 2 I/O modules in the Microbox PC 42x system ■ Technical specifications Electrical data Supply voltages and current consumption Parameters Value Power supply to base module Via PCI-104 interface: 3.3 V DC and 5 V DC Encoder supply voltage infeed 24 V DC Current consumption of encoder inputs and counters 0.3 A per encoder Power supply to digital I/O module 0 24 V DC Current consumption of digital I/O module 0, max. approx. 4A Power supply to analog I/O module 0 5 V DC from Base 400 Current consumption of analog I/O module 0, max. approx. 5/156 Siemens ST 80 / ST PC · 2013 For expanding a SIMATIC Microbox PC 420/427B/IPC427C. © Siemens AG 2013 PC-based Automation Expansion components and accessories PC I/O ■ Technical specifications (continued) Digital I/O module 0: Digital outputs Counters and encoder inputs Parameters Value Parameters Value Number of counters or encoder inputs on the base module 4 Number of outputs 16, Organized in 4 output groups Input signal from encoder RS 422 32 bits Cable length (without lightning protection element) max. 30 m Counting depth Encoder input counting frequency ≤ 2 MHz Output voltage 24 V DC Output current: • Per output group • Total per digital I/O module 0 1 A max. 4 A max. Switching rate ≤ 2 kHz Switching type Current sourcing Sampling time for timer or pulse-width measurement 1 MHz or 4 MHz Gate time for frequency measurement Adjustable in the following stages: 8 µs, 32 µs, 128 µs, 512 µs, 2048 µs, 8192 µs, 16384 µs, 32768 µs, 131072 µs, 262144 µs, 524288 µs, 1048576 µs, 2097152 µs, 4194304 µs, 8388608 µs, 16777216 µs Output delay: Internal transmission delay 16 µs Isolation No Protected against polarity reversal No Register output to driver output (load-dependent): • 0 → 1 signal • 1 → 0 signal (with a digital input connected) Base module: Digital inputs Isolation: Yes Parameters Value Number of digital inputs 4 For communication between the base module and the outputs of digital I/O module 0 Cable length (without lightning protection element) max. 30 m Isolation test voltage 500 V DC No, one electrical circuit Input voltage 24 V DC Between the individual inputs/outputs of digital I/O module 0 Input current Approx. 2 mA Short-circuit protection of the output drivers Threshold on Time constant of input filter 0.01 ms Isolation No Digital inputs on base module max. 30 µs max. 130 µs Typ. 9 A max. 11 A electronically pulsing In order to comply with UL requirements, the user must limit the input current to 4 A. Digital I/O module 0: Digital inputs: Use NEC Class 2 current source Parameters Value Excess temperature shutdown Above 150 °C Number of digital inputs 24 Overvoltage protection Cable length (without lightning protection element) max. 30 m Typ. 47 V max. 52 V 24 V DC Status after POWER ON and after RESET High resistance Input voltage Input current Approx. 2 mA Time constant of input filter: • Inputs 0 … 7 • Inputs 8 … 23 • Inputs 8 and 9 also designed as high-speed inputs (parallel to 1 ms path) 0.1 ms 1 ms 0.01 ms Isolation For communication between the base module and the inputs of digital I/O module 0 Yes Isolation test voltage 500 V DC Between the individual inputs/outputs of digital I/O module 0 No, one electrical circuit Siemens ST 80 / ST PC · 2013 5/157 5 © Siemens AG 2013 PC-based Automation Expansion components and accessories PC I/O ■ Technical specifications (continued) Analog I/O module Analog I/O module 0: Analog outputs Analog I/O module 0: Analog inputs Parameters Value Parameters Value Number of analog inputs 8 Number of analog outputs 8 Shielded cable length max. 30 m Type Single-ended Voltage ranges 0…5V 0 … 10 V ±5 V ±10 V Shielded cable length max. 30 m Voltage range ±10 V Load current 2 mA max. max. 15 V, continuous Resolution 16 bits (including sign) Accuracy 0.5 % Conversion time max. 200 µs per channel Output value after POWER ON and after RESET 0V Permissible input voltage against analog ground Impedance > 10 kOhms Input type Single-ended Resolution 12 bits (including sign) Repeatability 10 bits (including sign) Input filters No Conversion time max. 200 µs per channel Configuration cycle time for analog-to-digital conversion: • With one analog input • With 4 analog inputs • With 8 analog inputs Without Pt100 With Pt100 50 ... 100 µs 200 ... 400 µs 400 ... 800 µs 50 ... 200 µs 200 ... 500 µs 400 ... 1000 µs Isolation No Analog I/O module: Pt100 inputs 5 Parameters Value Number of external Pt100 inputs 4 Type Two-wire measurement Dynamic response The mean value is constantly available and is updated approximately every 6 ms. Isolation No 5/158 Siemens ST 80 / ST PC · 2013 Configuration cycle time for digital-to-analog conversion1): • With one analog input • With 4 analog inputs • With 8 analog inputs 100 ... 200 µs 400 ... 800 µs 800 ... 1600 µs Short-circuit protection No Isolation No 1) The times also depend on the software response time (interrupt response time or polling times). © Siemens AG 2013 PC-based Automation Expansion components and accessories PC I/O ■ Technical specifications (continued) Environmental requirements for installation in Microbox PC 42x Degree of protection to EN 60529 (front/rear) IP20 Protection class Protection class I acc. to VDE 0106 Part 1 (IEC 536) Vibration load during operation Devices without hard disk: Frequency Acceleration Displacement Cycles per axis Octaves/min 10 to 58 Hz - 0.075 mm 10 1 58 to 200 Hz 9.8 m/s2 - 10 1 Displacement Cycles per axis Octaves/min acc. to IEC 60068-2-6, test Fc Devices with hard disk: Wall mounting Frequency Acceleration 10 to 58 Hz 0.035 mm 10 1 58 to 200 Hz 4.9 m/s2 10 1 Standard rail: No mechanical excitation permitted Shock loading during operation Devices without hard disk: Acceleration Shock duration 150 m/s2 11 ms acc. to IEC 60068-2-27, test Ea 3 in both pos. and neg. direction per axis, half-sine Devices with hard disk: Wall mounting: Acceleration Shock duration 50 m/s2 30 ms Standard rail: No mechanical excitation permitted Electromagnetic compatibility (EMC) • Emitted interference • Immunity to conducted interference on the supply lines • Immunity to conducted interference on the unshielded supply lines • Immunity to conducted interference on the shielded supply lines • Immunity to static discharge • Immunity to radio frequ. interference • Immunity to high-frequ. current feed EN 55022 Class B In order to comply with Class B, a 230 V AC power supply unit must be used which meets the requirements of EN 55022 Class B (e.g. "SITOP modular 5 A", type No.: 6EP1333-3BA00). • ±2 kV (IEC 61000-4-4, Burst) • ±1 kV (IEC 61000-4-5, symm. surge, length > 30 m) with lightning protection element (e.g. from Dehn, type "Blitzductor BVT AD24", type No.: 918402) • ±2 kV (IEC 61000-4-5, unsymm. surge, length > 30 m) with lightning protection element (e.g. from Dehn, type "Blitzductor BVT AD24", type No.: 918402) • ±2 kV (IEC 61000-4-4, burst) • ±1 kV (IEC 61000-4-5, symm. surge, length > 30 m) with lightning protection element (e.g. from Dehn, type "Blitzductor BVT AD24", type No.: 918402) • ±2 kV (IEC 61000-4-5, unsymm. surge) Length > 30 m) with lightning protection element (e.g. from Dehn, type "Blitzductor BVT AD24", type No.: 918402) • ±2 kV (IEC 61000-4-4, burst) • ±1 kV (IEC 61000-4-5, surge symm., length > 30 m) • ±2 kV (IEC 61000-4-5, surge unsymm., length > 30 m) • ±6 kV, contact discharge (IEC 61000-4-2) • ±8 kV, air discharge (IEC 61000-4-2) • 10 V/m 80 % AM; 80 MHz to 1 GHz (IEC 61000-4-3); • 10 V/m 80 % AM; 1.4 GHz to 2 GHz (IEC 61000-4-3) • 10 V 80 % AM, 9 kHz to 80 MHz (IEC 61000-4-6) Ambient temperature during operation • 0 to 50 ºC with Flash drive (horizontal; preferred mounting position) • 0 to 45 ºC with Flash drive (vertical) • 5 to 40 ºC with hard disk (horizontal and vertical) Ambient temperature during storage and transport -20 °C … +60 °C Moist heat 30 °C/85 % (IEC 60068-2-78, Test Cab) 5 Approvals Safety regulations IEC/EN 60950-1 CE marking • EC Directive 89/336/EEC (EMC Directive) • Use in industry: • Applications in residential areas, business and trade environments as well as in workshops: - Emitted interference: EN 61000-6-4 - Noise immunity: EN 61000-6-2 • Applications in residential areas, business and trade environments as well as in workshops: - Emitted interference: EN 61000-6-3 - Noise immunity: EN 61000-6-1 Dimensions and weights Equipment dimensions (in mm) • • • • • Width x height: 262 x 134 Depth of basic unit: 47 Depth of basic unit above rail: 52 Additional depth per encoder expansion rack (Kit 040): 17 Additional depth per I/O expansion rack (Kit 030): 22 Siemens ST 80 / ST PC · 2013 5/159 © Siemens AG 2013 PC-based Automation Expansion components and accessories PC I/O ■ Ordering data PC IO Base 400 Order No. 6ES7648-2CE20-0AA0 PCI104 module for connecting up to 4 PC IO MOD xxx 010/020, with 4 encoder interfaces and 4 DI incl. fixing accessories (base module with fixing accessories) Order No. PC IO KIT 030 I/O module expansion rack for Microbox PC 420/427B/IPC427C for installing up to 2 I/O modules, including fixing accessories and a cover plate PC IO MOD Digital 010 Digital I/O module with 24 DI and 16 DO, incl. connecting cable to PC IO Base 400 and mating connector 6ES7648-2CE40-0BA0 PC IO KIT 040 PC IO MOD Analog 020 6ES7648-2CE40-0CA0 Encoder expansion rack for Microbox PC 420/427B/IPC427C for contacting the encoder interfaces and DIs of the PC IO Base 400, including fixing accessories Analog I/O module with 8 AI, 8 AO and 4 PT100, incl. connecting cable to PC IO Base 400, mating connector and shield clamp 5 5/160 6ES7648-1AA20-0XF0 Siemens ST 80 / ST PC · 2013 6ES7648-1AA20-0XE0 © Siemens AG 2013 PC-based Automation Expansion components and accessories SIMATIC Panel PC Remote Kit ■ Overview ■ Ordering data Order No. SIMATIC Panel PC Remote Kit 24 V DC, 5 m 6AV7671-1EA00-5AA1 24 V DC, 10 m 6AV7671-1EA01-0AA1 24 V DC, 15 m 6AV7671-1EA01-5AA1 24 V DC, 20 m 6AV7671-1EA02-0AA1 24 V DC, 30 m 6AV7671-1EA03-0AA1 100/240 V AC, 5 m 6AV7671-1EA10-5AA1 100/240 V AC, 10 m 6AV7671-1EA11-0AA1 100/240 V AC, 15 m 6AV7671-1EA11-5AA1 100/240 V AC, 20 m 6AV7671-1EA12-0AA1 100/240 V AC, 30 m 6AV7671-1EA13-0AA1 Accessories Power supply cable The Remote Kit makes it possible to separate the Panel PC 677B operator control unit from the computer unit and install them up to 30 m apart. ■ Technical specifications SIMATIC Panel PC Remote Kit Europe: D/F/NL/E/B/A/S/FIN 1) 6ES7900-1AA00-0XA0 United Kingdom 6ES7900-1BA00-0XA0 Switzerland 6ES7900-1CA00-0XA0 USA 6ES7900-1DA00-0XA0 Italy 6ES7900-1EA00-0XA0 China 6ES7900-1FA00-0XA0 Sub-components of the Remote Kit (only available individually as spare parts) Design Subsequent installation on the Panel PC 677B operator control unit Supported operator control units All Panel PC 677B operator control units: • 12" Touch/Key • 15" Touch/Key • 17" Touch • 19" Touch 24 V DC remote module with fixing accessories 6AV7671-1EX01-0AD0 110/240 V AC remote module with fixing accessories 6AV7671-1EX01-0BD0 USB amplifier/CAT6 converter 6AV7671-1EX02-0AB0 • • • • • 5 m cable set (DVI, USB standard cable) 6AV7671-1EX10-5AA0 10 m cable set (DVI, Cat 6 cable) 6AV7671-1EX11-0AA0 15 m cable set (DVI, Cat 6 cable) 6AV7671-1EX11-5AA0 20 m cable set (DVI, Cat 6 cable) 6AV7671-1EX12-0AA0 30 m cable set (DVI, Cat 6 cable) 6AV7671-1EX13-0AA0 Cable sets Front panel functionality 5m 10 m 15 m 20 m 30 m As centralized installation with the following constraint in respect of USB functionality: • Distance 5 m: USB 2.0, and only one external 2.0 Hub • Distance > 5 m: USB 1.1, and only one external 1.1 Hub External ports 2 additional USB ports on the remote module (on the rear of the remote operator control unit) Power supply 24 V DC; 20.4 ... 28.8 V DC or 110 ... 240 V AC; 50/60 Hz Approvals CE, cULus (UL 508) Scope of supply • Remote module • Cable set • Mounting accessories for the PC 677B computer unit • European power supply cable (with the AC option) 1) 5 A European power supply cable is included in the scope of delivery of the AC (100-240 V) version of the Remote Kit. Siemens ST 80 / ST PC · 2013 5/161 © Siemens AG 2013 PC-based Automation Expansion components and accessories SIMATIC Panel PC Remote Kit ■ Dimensional drawings All dimensions in mm. For mounting cut-out see technical specifications. Front dimensions H 400 483 483 310 310 400 483 483 310 355 W+1 H+1 D 368 450 450 290 290 380 95 93 102 450 450 290 321* 77 96 H W 10.5 W Touch panels 12" 15" 19" Key Panels 12" 15" Installation cutout W+1 (cutout) H+1 (cutout) Touch panels 12" 15" 19" Key Panels 12" 15" * In addition: two recesses 25 x 5 mm on the top side for keyboard slide-in label channels 5 5/162 Siemens ST 80 / ST PC · 2013 G_ST80_XX_00267 D © Siemens AG 2013 PC-based Automation Expansion components and accessories SIMATIC IPC Image & Partition Creator ■ Overview ■ Ordering data Order No. SIMATIC IPC Image & Partition Creator V3.3 Can be ordered using the SIMATIC IPC Configurator SIMATIC IPC Image & Partition Creator V3.3 Software tool for very easy preventive data backup and efficient partition management on SIMATIC IPCs 6ES7648-6AA03-3YA0 Note: SIMATIC IPC Image & Partition Creator is also available together with the SIMATIC IPC BIOS Manager preinstalled with the SIMATIC IPC Service USB FlashDrive. SIMATIC IPC Image & Partition Creator is the software tool for easy, preventive back-up and restoring of hard disk contents (images of individual partitions or complete hard disks). This software can be ordered through the Configurator for the SIMATIC IPCs, or separately with single license. • Can run on all SIMATIC IPCs, regardless of the computer configuration • Direct starting from the CD possible (no installation required) • Complete backup by means of a mouse double-click with "1ClickImage" (must be installed) • Menu-driven creation of a bootable USB flash drive as an alternative start medium from which SIMATIC IPC Image & Partition Creator can be started. • Independent of the operating system thanks to ability to start from the bootable SIMATIC IPC Image & Partition Creator CD or bootable USB flash drive with Image & Partition Creator 5 Siemens ST 80 / ST PC · 2013 5/163 © Siemens AG 2013 PC-based Automation Expansion components and accessories SIMATIC IPC DiagMonitor ■ Overview ■ Ordering data Can be ordered using the SIMATIC IPC Configurator SIMATIC IPC DiagMonitor V4.4 6ES7648-6CA04-4YX0 Software tool for monitoring the SIMATIC IPC, incl. manual on CD ROM (English, German), single license SIMATIC IPC DiagMonitor: Intelligent and comprehensive diagnostics for the SIMATIC IPC – local and remote. The SIMATIC IPC DiagMonitor software for monitoring and remote signaling detects possible hardware and software faults at an early stage. It monitors, signals and visualizes the operating statuses of the SIMATIC IPC both locally and remotely. 5 DiagMonitor V4.4 can run on the following SIMATIC IPCs: • Microbox PC 427B • Box PC 627B/827B • Rack PC IL 43 / 547B / 647B / 847B • Panel PC 477B/577B/677B • IPC427C / IPC627C / IPC827C • IPC547C / IPC647C / IPC847C • HMI IPC477C / HMI IPC477C PRO / HMI IPC577C / HMI IPC677C • IPC227D / IPC277D / IPC427D / IPC477D / IPC547D The software can be ordered as: • Individual product from stock (e.g. for server applications on third-party PCs or immediate integration in new systems) or • Option ordered according to the SIMATIC IPC configurator (Internet, Mall). (DiagMonitor V3.1 is used with SIMATIC Microbox PC 420/427B, Box PC 627/627B, Rack PC IL 43/840/847B, Panel PC 477/477B/ 677/677B/877 and can be ordered directly via the PC configurator or as an individual product.) 5/164 Siemens ST 80 / ST PC · 2013 Order No. SIMATIC IPC DiagMonitor V4.4 © Siemens AG 2013 PC-based Automation Expansion components and accessories SIMATIC IPC Remote Manager ■ Overview Remote diagnostics and access without on-site support • Troubleshooting • No operating system required • BIOS and program updates • Remote filling (supports ISO image > 2 GB) • Configurable time-out Control Production Administrator Without AMT AMT clients Central service Resource management • Easy access on SIMATIC IPC • No additional hardware (e.g. KVM switch) • Over secure connections • Saves electricity cost • Efficient use of production time G_ST80_XX_00443 With AMT SIMATIC IPC Remote Manager Efficient remote maintenance and management of SIMATIC IPCs. With the SIMATIC IPC Remote Manager you can use functions of the Intel active management technology (Intel AMT) for SIMATIC IPCs. Intel AMT is used for remote management of PCs. 5 Intel AMT offers a range of functions, such as: • Remote reboot • IDE redirection • Keyboard video mouse redirection • Power on / off / reset, and • an integrated Web server. http://support.automation.siemens.com/WW/view/en/56230140 ■ Ordering data SIMATIC IPC Remote Manager V1.2 Software tool for remote maintenance and management of SIMATIC IPC, incl. manual on CD-ROM (English, German), single license Order No. 6ES7648-6EA01-2YA0 Siemens ST 80 / ST PC · 2013 5/165 © Siemens AG 2013 PC-based Automation Expansion components and accessories SIMATIC IPC BIOS Manager ■ Overview ■ Ordering data SIMATIC IPC BIOS Manager Software tool for the management and processing of SIMATIC IPC BIOS data Order No. available as a download from Customer Support http://support.automation.siemens.com/WW/ view/en/58512643 Note: SIMATIC IPC BIOS Manager is also available together with the SIMATIC IPC USB FlashDrive and IPC Service USB FlashDrive. The SIMATIC IPC BIOS Manager V3.3 (WinPE) is a software tool for the management and processing of SIMATIC IPC BIOS data. The tool is obtained by downloading it from the Service & Support web pages of Industry Automation & Drive Technologies using the Automation Value Card. http://support.automation.siemens.com/WW/view/en/58512643 5 5/166 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation Input and output devices SIMATIC PC keyboard ■ Overview ■ Ordering data The original SIMATIC PC keyboard is the ideal input medium for your SIMATIC PC. It combines the convenience of an office keyboard with the ruggedness of an industrial device. The SIMATIC PC keyboard is available with a USB connection and German/international layout. SIMATIC PC keyboard Order No. 6ES7648-0CB00-0YA0 German/international, USB connection incl. USB-PS2 adapter ■ Technical specifications SIMATIC PC keyboard Description SIMATIC PC keyboard Layout MF2, 105 keys, German/international Dimensions (L x W x H) in mm 470 x 195 x 44 Weight, approx. 1400 g Connecting cable Length 1.75 m, USB plug Temperature • During operation • Storage 0 ... +50 °C -20 ... +60 °C Current consumption - Current delivery - Transmission rate - Approvals FCC, cURus, GS, CE, c-tick, GOST-R 5 Siemens ST 80 / ST PC · 2013 5/167 © Siemens AG 2013 PC-based Automation Input and output devices IP65 membrane keyboard, desk version ■ Overview ■ Ordering data The desktop version of the IP65 membrane keyboard is ideal for use in industrial areas in which a high degree of protection (IP65) is required. The keyboard is equipped with a touchpad. ■ Technical specifications • Color “light-basic” • MF2/Windows 95 compatible key layout with 105 short-stroke keys, type Omron • German or international key layout • Desktop unit made of polyester • Mounting plate and base made of metal • Front membrane made of resistant polyester (150 µm thick) • 1 million strokes per key • Y cable with 2 PS/2 connectors with 1.8 m connecting cable • Weight approx. 1190 g • Dimensions in mm (W x D x H): 478.6 x 180 x 26 • Licences: UL 1950, CSA C22.2 No. 950 • CE conformity according to EC 89/336 • Degree of protection IP65 Order No. Standard configuration IP65 membrane keyboard, desktop version with touchpad With PS/2 connector • German keyboard layout • International keyboard layout 6GF6710-2AC 6GF6710-2BC IP65 membrane keyboard, 19" built-in version ■ Overview 5 ■ Ordering data The built-in version of the IP65 membrane keyboard is ideal for use in industrial areas in which a high degree of protection (IP65 at the front, IP54 at the rear) is required. The keyboard is specially designed for installation in 19" cabinets. ■ Technical specifications • Color “light-basic” • MF2/Windows 95 compatible key layout with 105 short-stroke keys, type Omron • German or international key layout • Desktop unit made of polyester • 19“/4HU mounting plate made of metal (1.6 mm thick) • Front membrane made of resistant polyester (180 µm thick) • Touchpad or trackball (IP65 version) • Y cable with 2 PS/2 connectors with 1.8 m connecting cable • Weight approx. 1480 g • Dimensions in mm (W x D x H): 482.6 x 177.8 x 42.5 • Licences: UL 1950, CSA C22.2 No. 950 • CE conformity according to EC 89/336 • IP65 protection at the front, IP54 at the rear 5/168 Siemens ST 80 / ST PC · 2013 Order No. Standard configuration IP65 membrane keyboard, 19" built-in version For installation in 19" cabinets With touchpad • German keyboard layout • International keyboard layout 6GF6710-3AE 6GF6710-3BE With trackball • German keyboard layout • International keyboard layout 6GF6710-3BF 6GF6710-3BG © Siemens AG 2013 PC-based Automation Input and output devices 19" slide-in keyboard PS/2 with trackball ■ Overview With its compact design and integrated trackball the new drawout keyboard is suitable in particular for industrial applications with limited space. This can be, for example, cubicles or mobile systems. The draw-out keyboard is supplied in combination with a drawer. ■ Ordering data Order No. Standard configuration 19" withdrawable keyboard With trackball • German keyboard layout • International keyboard layout 6GF6710-3BJ 6GF6710-3BK SIMATIC IPC mouse ■ Overview Robust mouse for harsh everyday use with a pleasantly coated slip-free surface, precise BlueTrack technology, three buttons incl. large scroll wheel, trouble-free cable operation and symmetrical casing design for right-handed and left-handed users. • Interface: USB • Operating systems: Microsoft Windows® 7, Windows Vista® and Windows XP (not for Windows XP 64 bit) • Connection cable: 2 m long, USB plug • Approvals corresponding to office environment: - ACA/MED Declaration of Conformity (Australia and New Zealand) - ICES-003 report on file (Canada) - EIP Pollution Control Mark, EPUP (China) - CE Declaration of Conformity, Safety and EMC (European Union) - WEEE (European Union) - VCCI Certificate (Japan) - KCC Certificate (Korea) - GOST Certificate (Russia) - BSMI Certificate (Taiwan) - FCC Declaration of Conformity (USA) - UL and cUL Listed Accessory (USA and Canada) - CB Scheme Certificate (International) ■ Ordering data Order No. SIMATIC IPC mouse Optical (BlueTrack) wheel mouse, USB interface Color • Anthracite • White 6ES7648-0BB00-0XA0 6ES7648-0BB00-0XA1 5 Siemens ST 80 / ST PC · 2013 5/169 © Siemens AG 2013 PC-based Automation SITOP power supplies SITOP power supplies ■ Overview The complete SITOP range In addition to the power supplies, the perfectly coordinated, complete range offers a unique choice of modules - from those that protect the 24 V power supply against interference on the primary and secondary side, right up to those providing complete protection. Every day, SITOP is used successfully in innumerable practical applications and protects against plant downtimes and production outages. Quick selection and fast delivery With the SITOP Selection Tool - available in the Internet under http://www.siemens.com/sitop-selection-tool and in the Industry Mall – the suitable power supply can be selected quickly and easily, the selected products can be saved or placed into the Mall's shopping cart and then ordered there. We deliver all SITOP standard products from stock to ensure that you receive the SITOP power supply you selected quickly. Customized SITOP products SITOP – reliable 24 V power supply Efficient operation of a machine or plant requires a reliable, constant power supply. The quality and reliability of the SITOP stabilized power supplies ensure high levels of safety in DC power supply in industrial engineering and building management systems. They supply a stabilized 24 volts, but also other output voltages. Even in the case of large input voltage variations, the output voltage is kept stable with a high degree of accuracy. This enables the use of primary switchedmode power supplies in many applications for the supply of sensitive electronic systems - all the way up to loads requiring high currents. 5 The fan-free power supplies are characterized by their compact and rugged design, high overload capability, as well as special energy efficiency. The high efficiency across the entire load range and the low no-load loss ensure efficient operation. The large input voltage range and the international approvals mean that use is possible in almost all supply networks worldwide. 5/170 Siemens ST 80 / ST PC · 2013 Our standard power supplies cannot, of course, satisfy the requirements of every application. We can design a specific power supply for your application-specific requirements. You benefit from the expertise of large-scale production and gain maximum development security and quality. Our customer-specific solutions are used today in many sectors of mechanical engineering, in automation technology, vehicle electronics, equipment manufacturing, or in industrial instrumentation technology. If your are interested, please contact your local Siemens office. © Siemens AG 2013 PC-based Automation SITOP power supplies 1-phase, 24 V DC/10 A (SITOP PSU100S) 1-phase, 24 V DC/20 A (SITOP PSU100S) ■ 1-phase, 24 V DC/10 A (SITOP PSU100S) The single-phase power supply for universal use; complies with EU directive 94/9/EC (ATEX 100a); slim design; with 50 % extra power for 5 s and 120 % rated power up to 45 °C. ■ Ordering data SITOP PSU100S 24 V/10 A Order No. 6EP1334-2BA20 Stabilized power supply Input: 120/230 V AC Output: 24 V DC/10 A SITOP smart 240 W ■ 1-phase, 24 V DC/20 A (SITOP PSU100S) High-performance, standard power supply for 1-phase 120/230 V AC grids, with automatic range switching; high overload capability through Extra power with 1.5 times the rated current for 5 s and continuous 120 % output power up to +45 °C ambient temperature. ■ Ordering data Order No. SITOP PSU100S 20A Stabilized power supply; Input: 120/230 V AC, Output: 24 V DC/20 A 6EP1336-2BA10 6EP1334-2AA01 Stabilized power supply Input: 120/230 V AC Output: 24 V DC/10 A SIPLUS smart 10 A 5 6AG1334-2BA20-4AA0 For medial load based on 6EP1334-2BA20 Siemens ST 80 / ST PC · 2013 5/171 © Siemens AG 2013 PC-based Automation SITOP power supplies 3-phase, 24 V DC/10 A (SITOP PSU300S) 3-phase, 24 V DC/20 A (SITOP PSU300S) ■ 3-phase, 24 V DC/10 A (SITOP PSU300S) High-performance, standard power supply for 3-phase networks 3 AC 400-500 V, high overload capability through Extra power with 1.5 times the rated current for 5 s and continuous 120 % output power to +45° C ambient temperature. ■ Ordering data SITOP smart PSU300S 10 A Order No. 6EP1434-2BA10 Stabilized power supply; input: 3 AC 400 … 500 V; output: 24 V DC/10 A ■ Ordering data SITOP smart PSU300S 20 A Order No. 6EP1436-2BA10 Accessories 3RT1900-1SB20 5 5/172 High-performance, standard power supply for 3-phase networks 3 AC 400-500 V, high overload capability through Extra power with 1.5 times the rated current for 5 s and continuous 120 % output power to +45° C ambient temperature. Stabilized power supply Input: 3 AC 400 ... 500 V Output: 24 V DC/20 A Accessories Device labels ■ 3-phase, 24 V DC/20 A (SITOP PSU300S) Siemens ST 80 / ST PC · 2013 Device labels 3RT1900-1SB20 © Siemens AG 2013 PC-based Automation SITOP power supplies 3-phase, 24 V DC/40 A (SITOP PSU300S) ■ 3-phase, 24 V DC/ 40 A (SITOP PSU300S) ■ Ordering data Order No. SITOP PSU300S 40 A 6EP1437-2BA20 Stabilized power supply Input: 3 AC 400 … 500 V Output: 24 V DC/40 A Accessories SITOP PSE202U redundancy module 6EP1961-3BA21 Input/output: 24 V DC/40 A suitable for decoupling two SITOP power supplies with a maximum of 20 A output current Device labels 3RT1900-1SB20 High-performance, standard power supply for 3-phase networks 3 AC 400-500 V, high overload capability through Extra power with 1.5 times the rated current for 5 s and continuous 120 % output power to +45° C ambient temperature. 5 Siemens ST 80 / ST PC · 2013 5/173 © Siemens AG 2013 PC-based Automation 24 V DC uninterruptible power supplies 24 V DC uninterruptible power supplies ■ Overview Permanently reliable 24 V – even when the power fails: Uninterruptible power supply Supply network irregularities in the millisecond range are compensated for supremely well by all our power supplies. Large fluctuations or even power failures, however, require special measures: The buffer module (see SITOP add-on modules) ensures optimal protection in the case of brief power failures up to 3 seconds. Longer power failures into the minute range can be bridged with the new maintenance-free SITOP UPS500 with capacitor technology. The DC UPS modules with battery modules secure continued operation for hours! Both DC UPS systems can be integrated simply into PC-based automation solutions using a free software tool. Backup module SITOP DC UPS module SITOP UPS500 Expansion module with electrolyte capacitors for bridging temporary power failures. Can be combined with SITOP modular. DC UPS module with maintenance-free lead-gel batteries for energy storage. Bridging of power failures even for hours. DC UPS with high-capacity double-layer capacitors. Bridging of power failures for severyl minutes. Selection criteria: Selection criteria: Selection criteria: Low-cost protection against power failures for max. 3 seconds Supports the power supply unit when there is a temporary increased power demand High load current up to 40 A The 24 V power supply is maintained for a long time, e.g. in order to continue processes. High load current up to 40 A Backup data and closing of applications within minutes. Absolutely maintenance-free High ambient temperatures up to 60°C No ventilation is required since no gas is emitted For distributed applications without control cabinet G_ST80_XX_00486 5 The SITOP UPS500 is completely maintenance-free because it saves energy in high-capacitance double-layer capacitors. These have a long service life even in high temperatures, and do not need to be replaced. The installation location does not have to be ventilated because no gas is emitted. The innovative DC UPS buffers 24 V into the minutes range and makes it possible to back up data and to shut down PC-based applications (e.g. with SIMATIC PC) safely. The SITOP UPS500S is designed for installing on a standard mounting rail and it can be modularly expanded to extend the backup time. The UPS500P in degree of protection IP65 is suitable for distributed use. The SITOP DC UPS with battery modules using lead gel batteries up to 12 Ah enables process operation to continue for hours. The availability, battery supply line, aging status, and charge status are permanently monitored. The integral battery management system ensures optimal charging of the battery modules and a long service life. 5/174 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation 24 V DC uninterruptible power supplies 24 V DC uninterruptible power supplies ■ Overview (continued) SITOP power supply Load DC UPS module with battery module Messages - Mains or buffer operation - Buffer ready or alarm Charging status >85 % or <85 % via USB interface or floating relay contacts SITOP UPS500S basic unit 15 A maintanance-free with capacitor, optionally with expansion module as additional energy storage 24 V DC AC or 3 AC G_KT01_EN_00357 24 V DC USB interface for data exchange with industrial PC 5 DC UPS software The uninterruptible DC power supplies are optionally available with USB interface or serial interface. All relevant messages about the status of the uninterruptible DC power supply can be transferred to a PC (e.g. SIMATIC IPC) via this interface. SITOP DC UPS software provides the user with a very easy to use software tool with which the signals sent by the uninterruptible DC power supply can be further processed on the PC. In monitoring mode, the statuses of the uninterruptible DC power supply are visualized on the PC. Safe shutdown in the event of a power failure and automatic PC restart are supported. It is also possible to freely define responses to the different operating states of the uninterruptible DC power supply, so that extremely flexible integration into a wide variety of applications is possible. The software runs under the Windows 2000, Windows XP, Windows Vista and Windows 7 operating systems. It is available as downloadable freeware on the SITOP homepage. Monitoring and configuration window of software V3 for SITOP DC UPS http://www.siemens.com/sitop-ups ■ More information You can select the appropriate power supply quickly and easily using the SITOP Selection Tool: http://www.siemens.com/sitop-selection-tool Siemens ST 80 / ST PC · 2013 5/175 © Siemens AG 2013 PC-based Automation DC UPS with capacitors DC UPS with capacitors ■ Overview Uninterruptible power supplies normally store the electrical energy in lead-acid batteries. Temperatures such as those prevalent in control cabinets considerably shorten the service life of the battery, however, and the batteries must be replaced on a regular basis – annually at an ambient temperature of 40 °C, for example. The innovative SITOP UPS500, however, is based on absolutely maintenance-free capacitors with a long service life. Even at temperatures of 50 °C they still have more than 80% of their capacity after 8 years. This means that the energy storage unit does not have to be replaced. Because the capacitors do not emit any gas, the control cabinet does not have to be ventilated. Another advantage is the significantly shorter charging times of the double-layer capacitors, which ensure that the buffer is ready very quickly after loss of power. The SITOP UPS500P IP65 version has capacitors for 5 or 10 kW and supplies up to 7 A output current. The oblong metal enclosure is also suitable for installing on support arm systems. Selection table SITOP UPS500 (optional with SITOP UPS501S expansion module) and mains buffering times Buffering and charging times UPS500P SITOP UPS500S/501S configurations 5 Basic unit 2.5 kW 5 kW 2.5 kW 5 kW 2.5 kW 5 kW 2.5 kW 5 kW 5 kW 10 kW Expansion modules - - 1 × 5 kW 1 × 5 kW 2 × 5 kW 2 × 5 kW 3 × 5 kW 3 × 5 kW - - Total energy 2.5 kW 5 kW 7.5 kW 10 kW 12.5 kW 15 kW 17.5 kW 20 kW 5 kW 10 kW Load current Buffer times 0.5 A 134 s 236 s 390 s 478 s 632 s 748 s 851 s 1007 s 284 s 647 s 0.8 A 90 s 167 s 266 s 346 s 440 s 527 s 580 s 706 s 190 s 435 s 1A 75 s 138 s 219 s 296 s 365 s 414 s 490 s 572 s 153 s 351 s 2A 38 s 76 s 122 s 156 s 203 s 230 s 265 s 306 s 80 s 152 s 3A 26 s 52 s 82 s 106 s 136 s 159 s 186 s 213 s 53 s 108 s 4A 19 s 39 s 61 s 81 s 101 s 120 s 139 s 160 s 40 s 84 s 5A 15 s 31 s 49 s 65 s 81 s 95 s 111 s 130 s 30 s 68 s 6A 12 s 26 s 40 s 55 s 67 s 80 s 94 s 106 s 25 s 57 s 7A 10 s 21 s 34 s 47 s 58 s 69 s 81 s 82 s 21 s 49 s 8A 8s 18 s 29 s 40 s 50 s 59 s 69 s 79 s - - 10 A 6s 15 s 23 s 32 s 39 s 47 s 54 s 62 s - - 12 A 4s 12 s 19 s 26 s 32 s 38 s 44 s 52 s - - 15 A 3s 9s 14 s 20 s 25 s 30 s 35 s 40 s - - Charging current Charging times 2A 54 s 120 s 158 s 223 s 263 s 318 s 355 s 417 s 130 s 360 s 1A 110 s 205 s 311 s 425 s 503 s 625 s 695 s 816 s - - Important information for selecting the energy storage units: When the mains buffering times were determined, the discharge period of new or non-aged, completely charged capacitors was used as a basis. At a continuous ambient temperature of +50 °C, ■ More information You can select the appropriate power supply quickly and easily using the SITOP Selection Tool: http://www.siemens.com/sitop-selection-tool 5/176 Siemens ST 80 / ST PC · 2013 a loss of capacity of approx. 20% must be considered after a service life of 8 years. © Siemens AG 2013 PC-based Automation DC UPS with capacitors SITOP UPS500S ■ Overview Basic device 15 A, SITOP UPS500S • Compact design, only 120 mm wide • Two versions with integrated energy storage units: 2.5 kW or 5 kW • Can be expanded easily using a user-friendly plug-in system with the expansion module 5 kW • Absolutely uninterruptible bridging of power failures, as soon as the DC UPS input voltage falls below the value set by the DIP switches • High level of safety and availability through monitoring of operational readiness, and monitoring of the capacitor charge (message "> 85% charged") • Support for automatic warm restart of industrial PCs through selectable shutdown characteristics • With USB interface Maintenance-free power supply in the form of a combination of a basic module and an expansion module SITOP UPS501S expansion module • Additional energy storage (5 kW) • Up to 3 expansion modules can be connected to a SITOP UPS500S to extend the buffer times • Compact design, only 70 mm wide • Can be easily connected to SITOP UPS500S via a user-friendly plug-in system • Complete with balancing and safety circuits • Can be snapped onto standard mounting rail EN 60715 35x7.5/15 • Dimensions (W x H x D) in mm: Approx. 70 x 125 x 125 • Weight: Approx. 0.7 kg ■ Ordering data Order No. SITOP UPS500S DC UPS basic device 15 A with • 2.5 kW • 5 kW 6EP1933-2EC41 6EP1933-2EC51 SITOP UPS501S Expansion module 5 kW for connecting to the basic device 6EP1935-5PG01 Accessories Device labels 3RT1900-1SB20 Siemens ST 80 / ST PC · 2013 5/177 5 © Siemens AG 2013 PC-based Automation DC UPS with capacitors SITOP UPS500P ■ Overview ■ Ordering data Order No. SITOP UPS500P DC UPS basic device 7 A with • 5 kW • 10 kW Connector set consisting of connector for input and output and an assembled USB cable (2 m in length) Basic device 7 A, IP65, SITOP UPS500P • Compact design, degree of protection IP65 • For distributed use, e.g. on support arms • Integrated energy storage: 5 kW or 10 kW • Ambient temperature range for operation: 0 to +55 °C • High degree of efficiency 96.9% or low power loss, approx. 6 W with 7 A load current • USB interface • Indication of the operating states normal operation, buffer mode, alarm message "Buffer not ready" and indication of the capacitor charge > 85% 5 5/178 Siemens ST 80 / ST PC · 2013 6EP1933-2NC01 6EP1933-2NC11 6EP1975-2ES00 © Siemens AG 2013 PC-based Automation DC UPS with battery modules DC UPS with battery modules ■ Overview By combining a DC UPS module with at least one 24 V battery module and a SITOP power supply unit, longer power failures can be bridged without any interruption. The combination is used for example in machine-tool building, in the textile industry, on all types of production lines and filling plants, and in conjunction with 24 V industrial PCs. This prevents the negative effects which often result from power failures. DC UPS modules: 6 A, 15 A, 40 A Battery modules: • 1.2 Ah (contains lead-acid batteries with corrosion-resistant lead-calcium high-performance grid plates and fiberglass mat) • 3.2 Ah (contains lead-acid batteries with corrosion-resistant lead-calcium high-performance grid plates and fiberglass mat) • 7 Ah (contains lead-acid batteries with corrosion-resistant lead-calcium high-performance grid plates and fiberglass mat) • 12 Ah (contains lead-acid batteries with corrosion-resistant lead-calcium high-performance grid plates and fiberglass mat) • 2.5 Ah (contains "high-temperature battery" type pure lead) Selection table for battery modules and mains buffering times Load current Battery module 1.2 Ah (6EP1935-6MC01) Battery module 3.2 Ah (6EP1935-6MD11) Battery module 7 Ah (6EP1935-6ME21) Battery module 12 Ah (6EP1935-6MF01) Battery module 2.5 Ah (6EP1935-6MD31) 1A 34.5 min 2.6 h 5.4 h 9h 2h 2A 15 min 1h 2.6 h 4.6 h 1h 3A 9 min 39.3 min 1.6 h 2.9 h 37.5 min 4A 6.5 min 27.1 min 1.2 h 2.2 h 27 min 6A 3.5 min 17.5 min 41 min 1.2 h 17.6 min 8A - 12.1 min 28.6 min 53.3 min 12.5 min 10 A - 9 min 21.8 min 43.5 min 8.8 min 12 A - - 17.3 min 33.3 min 6.8 min 14 A - - 15.1 min 27.5 min 5.1 min 16 A - - 12.5 min 23.8 min 4.3 min 20 A - - 9.1 min 20.1 min - 25 A - - - 12.6 min - 30 A - - - 9.1 min - Important information for selecting the battery capacity: • Determination of the mains buffering times is based on the discharge period of new or non-aged, completely charged battery modules at a battery temperature not below +25 °C to the shutdown of the DC UPS. • Battery aging reduces the still available battery capacity up until the end of the service life to typically around 50 % of the original capacity value when new (1.2 Ah/3.2 Ah/7 Ah, etc.) and the internal resistance increases. When the message "Battery charge > 85%" appears, only around 50% x 85% = approx. 43% of the originally available capacity can be assumed at the end of the battery service life. 5 At battery temperatures below +25 °C, the available capacity is further reduced by approx. 30% at +5 °C battery temperature to approx. 70% of approx. 43%, leaving only approx. 30% of the original capacity available. Accordingly, a significantly greater battery capacity must be selected when configuring the system: A drop to approx. 50% is compensated for by selecting 1/approx. 0.5 = approx. double the battery capacity (than required according to the table for the relevant load current and the relevant buffering time). Available capacity of approx. 43% is compensated for by selecting 1/approx. 0.43 = approx. 2.33 times the battery capacity. Available capacity of approx. 30% is compensated for by selecting 1/approx. 0.3 = approx. 3.33 times the battery capacity. Siemens ST 80 / ST PC · 2013 5/179 © Siemens AG 2013 PC-based Automation DC UPS with battery modules DC UPS with battery modules ■ Overview (continued) ■ More information Recommendation: • Instead of installing double the battery capacity to cope with battery aging, regular battery replacement midway through the expected service life (reduction of capacity to approx. 50%) can be more advisable for the following reasons: Until the middle (or somewhat past the middle) of the anticipated battery service life is reached, the capacity does not drop below 100 %. If the battery is replaced on a regular basis after reaching half of the anticipated service life, only single (instead of double) battery capacity must be installed (→ neutral price in terms of battery module costs, but only half of the space requirement). When swapped after half of the service life, the large scatter range of the residual capacity, which is not defined in more detail by battery manufacturers, can be avoided at the end of the service life (after the full time, many batteries are over or under the average of 50 % remaining capacity; this means that even if double the capacity is installed, the effect of aging at the end of the service life is not reliably compensated for, but only typically). If the battery is swapped after half of the anticipated service life, the projected buffering time is much more reliably adhered to. For batteries stored in a cool place below +25 °C and for no longer than approx. 4 months, the following service life can usually be assumed, highly dependent on the battery temperature): 5 Battery temperature Drop to approx. 50% of residual capacity Recommendation: Replace (at 100% of residual capacity) all +20 °C 4 years 2 years +30 °C 2 years 1 year +40 °C 1 year 0.5 years Alternative recommendation Install double capacity and replace 1 x per year In normal cases (installation in the coolest location in the control cabinet at approx. +30 °C), the battery should be replaced with single installed battery capacity in accordance with the selection table after 1 year of operation! • On the DC UPS module 40 A, at least 2 battery modules of 7 Ah or higher must be connected in parallel for output currents > 30 A. When connecting battery modules in parallel, you must ensure identical capacity and aging. • After a power failure, and at the end of the selected buffering time, the battery module is disconnected electronically from the loads as soon as the 24 V input voltage returns either automatically or by opening the On/Off control circuit, and quickly recharged with the charge current of the relevant DC UPS module (with I-U charge characteristic: initially constant current I for fast charging, and changeover to constant voltage U to maintain the charge when the battery is almost full). 5/180 Siemens ST 80 / ST PC · 2013 You can select the appropriate power supply quickly and easily using the SITOP Selection Tool: http://www.siemens.com/sitop-selection-tool © Siemens AG 2013 PC-based Automation DC UPS with battery modules DC UPS module 6 A DC UPS module 15 A ■ SITOP DC UPS module 6 A ■ SITOP DC UPS module 15 A • Compact design, only 50 mm wide • Simple DIN rail mounting • Completely uninterruptible mains buffering through immediate electronic connection of the battery as soon as the DC UPS input voltage falls below the value set by means of DIP switches. • High level of safety and availability through monitoring of operational readiness, battery supply line, battery aging (message "Battery replacement necessary") and battery charge (message "Battery charged >85 %") • Support for automatic warm restart of industrial PCs through selectable shutdown characteristics. • Optionally with serial or USB interface. SW tool available for download from http://www.siemens.com/sitop Executes under Windows NT4.0, Windows 2000 and Windows XP. ■ Ordering data SITOP DC UPS module 6 A • With serial interface • With USB interface Order No. 6EP1931-2DC21 6EP1931-2DC31 6EP1931-2DC42 • Compact design, only 50 mm wide • Completely uninterruptible mains buffering through immediate electronic connection of the battery as soon as the DC UPS input voltage falls below the value set by means of DIP switches. • High level of safety and availability through monitoring of operational readiness, battery supply line, battery aging (message "Battery replacement necessary") and battery charge (message "Battery charged >85%") • Support for automatic warm restart of industrial PCs through selectable shutdown characteristics. • Optionally with serial or USB interface. SW tool available for download from http://www.siemens.com/sitop Executes under Windows NT4.0, Windows 2000 and Windows XP. ■ Ordering data Order No. SITOP DC UPS module 15 A • With serial interface • With USB interface 6EP1931-2EC21 6EP1931-2EC31 6EP1931-2EC42 SIPLUS PS DC UPS module 15 A 6AG1931-2EC21-2AA0 (Extended temperature range -25 ... +60 °C) Siemens ST 80 / ST PC · 2013 5/181 5 © Siemens AG 2013 PC-based Automation DC UPS with battery modules DC UPS module 40 A Battery module 1.2 Ah ■ SITOP DC UPS module 40 A 5 ■ Battery module 1.2 Ah • Compact design, only 102 mm wide • Completely uninterruptible mains buffering through immediate electronic connection of the battery as soon as the DC UPS input voltage falls below the value set by means of DIP switches. • High level of safety and availability through monitoring of operational readiness, battery supply line, battery aging (message "Battery replacement necessary") and battery charge (message "Battery charged >85 %") • Support for automatic warm restart of industrial PCs through selectable shutdown characteristics. • Optionally with USB interface. SW tool available for download from http://www.siemens.com/sitop Executes under Windows NT4.0, Windows 2000 and Windows XP. ■ Ordering data Order No. SITOP DC UPS module 40 A • With USB interface 6EP1931-2FC21 6EP1931-2FC42 SIPLUS PS DC UPS module 40 A 6AG1931-2FC21-7AA0 (extended temperature range +25 A ... +70 A °C and medial loading) 5/182 Siemens ST 80 / ST PC · 2013 • Battery module for DC UPS module 6 A • It has two maintenance-free, closed lead-acid batteries (from the same lot) which are installed in a holder and connected in series with corrosion-resistant lead-calcium high-performance grid plates and glass fiber. • Completely prewired with battery retainer and terminals • Low self-discharge rate of approximately 3 % per month (at +20 °C) ■ Ordering data Battery module 24 V/1.2 Ah for DC UPS module 6 A Order No. 6EP1935-6MC01 © Siemens AG 2013 PC-based Automation DC UPS with battery modules Battery module 2.5 Ah Battery module 3.2 Ah ■ Battery module 24 V/2.5 Ah ■ Battery module 24 V/3.2 Ah • High-temperature battery module for DC UPS module 6 A and 15 A • It has two maintenance-free, closed pure lead-acid batteries (from the same lot), which are installed in a holder and connected in series. • Completely prewired with battery retainer and terminals • Low self-discharge rate of approximately 3 % per month (at +20 °C) ■ Ordering data Battery module 24 V/2.5 Ah for DC UPS module 15 A Order No. 6EP1935-6MD31 • Battery module for DC UPS module 6 A and 15 A • It has two maintenance-free, closed lead-acid batteries (from the same lot) which are installed in a holder and connected in series with corrosion-resistant lead-calcium high-performance grid plates and glass fiber. • Complete with battery retainer and terminals • Low self-discharge rate of approximately 3 % per month (at +20 °C) ■ Ordering data Battery module 24 V/3.2 Ah Order No. 6EP1935-6MD11 for DC UPS module 15 A 5 Siemens ST 80 / ST PC · 2013 5/183 © Siemens AG 2013 PC-based Automation DC UPS with battery modules Battery module 7 Ah Battery module 12 Ah ■ Battery module 7 Ah ■ Battery module 12 Ah • Battery module for DC UPS module 6 A, 15 A and DC UPS module 40 A (for > 30 to 40 A, 2 units are required in parallel) • It has two maintenance-free, closed lead-acid batteries (from the same lot) which are installed in a holder and connected in series with corrosion-resistant lead-calcium high-performance grid plates and glass fiber. • Completely pre-wired with terminals and battery retainer • Low self-discharge rate of approximately 3% per month (at +20 °C) ■ Ordering data Battery module 24 V/7 Ah 5 Order No. 6EP1935-6ME21 for DC UPS module 6 A, 15 A and 40 A 5/184 Siemens ST 80 / ST PC · 2013 • Battery module for DC UPS module 6 A, 15 A and DC UPS module 40 A (for > 30 to 40 A, 2 units are required in parallel) • It has two maintenance-free, closed lead-acid batteries (from the same lot) which are installed in a holder and connected in series with corrosion-resistant lead-calcium high-performance grid plates and glass fiber. • Completely pre-wired with terminals and battery retainer • Low self-discharge rate of approximately 3% per month (at +20 °C) ■ Ordering data Battery module 24 V/12 Ah for DC UPS module 6 A, 15 A and 40 A Order No. 6EP1935-6MF01 © Siemens AG 2013 PC-based Automation MASTERGUARD power supply MASTERGUARD power supply ■ Overview ■ More information MASTERGUARD UPS • The A-19 and EI-19 series of Masterguard offer effective online protection against all kinds of power supply disturbances • Genuine online operating principle, i.e. complete disconnection of the load from the irregularities of the line power supply • 19" compact modules • Simple operation and functional indication of operating states and load stages http://www.masterguard.de MASTERGUARD UPS Series A-19/EI-19 • Permanent double-converter technology evens out any irregularity in the power supply and offers totally uninterrupted protection • Easily configurable for use in 19" cabinets thanks to battery expansions and universal slide rail units • With a height of just 2 HU for the A-19 series and 3 HU for the EI-19 series and with power-regulated fan and functional display, these units are ideal where space is limited. • For communication, a choice can be made between serial and USB interface and, in addition, a network connection of the UPS can be set up by means of an SNMP plug-in card for the communication slot. Information hotline: +49 180-532 37 51 Sales contact: MASTERGUARD GmbH Mr. Willi Brinkmann Phone: +49 9131 6300 248 Fax: +49 9131 6300 271 E-mail: willi.brinkmann@masterguard.de Service contact: MASTERGUARD GmbH Mr. Alexander Zink Phone: +49 9131 6300 218 Fax: +49 9131 6300 281 E-mail: alexander.zink@masterguard.de Support line: +49 180-522 10 96 Standard configuration MASTERGUARD UPS Series A-19 • A700-19 Output: 700 VA; integrated battery: 6 min. • A1000-19 Output: 1000 VA; integrated battery: 7 min. • A2000-19 Output: 2000 VA • A3000-19 Output: 3000 A 5 Battery pack for MASTERGUARD Series A-19 • BPA 1000-19 for UPS A1000-19 (max. 2 BP) • BPA 3000-19 for UPS A2000-19 (max. 5 BP) and UPS A3000-19 (max. 5 BP) Accessories Slide rail unit 2 HU 330-580 mm Slide rail unit 2 HU 575-855 mm Standard configuration MASTERGUARD UPS Series El-19 • EI-19 Output: 6000 VA Battery pack for MASTERGUARD Series EI-19 • BPEI-19 Accessories Slide rail unit 3 HU 330-580 mm Slide rail unit 3 HU 575-855 mm ManageUPS SNMP adapter card MopUPS shutdown software • for Intel operating systems (Windows, Linux, Solaris for Intel) • for Risc operating systems (Solaris SPARC, HPUX, AIX) Siemens ST 80 / ST PC · 2013 5/185 © Siemens AG 2013 PC-based Automation Communication — Industrial Ethernet Connection options to SIMATIC IPCs ■ Overview The operating systems listed in the table refer exclusively to the communication products specified! Please refer to the description of the relevant IPC for the operating system that is available and has been released for that IPC. Embedded Systems - - SIMATIC S7 modular Embedded Controller - SIMATIC IPC627C ○ SIMATIC HMI IPC677C ○ SIMATIC Industrial-PC SIMATIC IPC427C, SIMATIC HMI IPC477C ○ Windows XP Embedded + SP1/SP2/FP 2007 SIMATIC IPC427C • • • • • • • • • - SIMATIC IPC627C SIMATIC IPC827C SIMATIC IPC547C/D Op. sys. • • • • ○ • • • • • ○ • ○ ○ • • • • • ○ • ○ ○ • • • • • • • • • • • • • • • • • • • • • • • • • • • • SIMATIC IPC847C Field PG M3 SIMATIC Industrial PC/ Field PG other operating systems Windows Server 2003 R2 / SP2 Windows XP Pro + SP3 Vista Business / Ultimate + SP1/2 Windows Server 2008 + SP1/2 Windows Server 2008 R2 Operating system environment of the communication software Windows 7 Professional / Ultimate Communication Communication hardware software CPs and software for Industrial Ethernet HARDNET-IE S7 (S7-1613) HARDNET-IE S7 REDCONNECT 3) S7 OPC Redundancy for Industrial Ethernet HARDNET-IE S7 (S7-1613) HARDNET-IE S7 REDCONNECT 3) S7 OPC Redundancy for Industrial Ethernet HARDNET-IE S7 (S7-1613) HARDNET-IE S7 REDCONNECT 3) S7 OPC Redundancy for Industrial Ethernet CP 1613 A2 (PCI 32 Bit) CP 1623 (PCIe x1) CP 1628 (PCIe x1) SOFTNET-IE S7 SOFTNET-IE S7 Lean SOFTNET-IE PG S7 OPC Redundancy for Industrial Ethernet SIMATIC PG/PC with integral Ethernet interface SOFTNET-IE S7 SOFTNET-IE S7 Lean SOFTNET-IE PG S7 OPC Redundancy for Industrial Ethernet • • • • • • - - - • • • • • • - - - • • • • • • • • • - - - • • • • • • • • • - - - - - • • • • • • • • ○5) • • ○5) • • • • • • • • • • • • • • • • • • • • • ○ - - ○ 4)5) 5) 5) 4)5) 5) 5) 4)5) - • • ○4)5) ○4)5) • • ○5) ○5) ○4)5) ○4)5) ○5) • ○ ○5) 5) ○4)5) ○4)5) • • • • • • • • • • • • • • • • • • • • • ○ - ○ ○ ○ ○ - - ○5) - • • • • CPs and software for PROFINET CP 1616 1) (PCI 32 Bit) HARDNET PN IO DK (DK-16xx PN IO) 1) CP 1604 1) (PCI-104) HARDNET PN IO DK (DK-16xx PN IO) 1) SIMATIC PG/PC with integral Ethernet interface SOFTNET PN IO • - - - • • - - - • • • • • • • 1) Use of these CPs requires porting of the Development Kit DK-16xx PN IO to the relevant operating system environment. You can order the DK-16xx PN IO at www.siemens.com/simatic-net/ dk16xx on the Internet. It contains sample software for Linux Suse 12 and Windows XP Professional. For IRT operation an exclusive interrupt is necessary; this is not available in all slots. The additional use of CP 1616/CP 1604 is not approved for SIMATIC Industrial PC versions and integrated PROFINET interface. 2) possible with restrictions, if necessary, depending on memory expansion and processor capacity 3) requires at least 2 PCI or 2 PCIe slots (4-way redundancy requires 4 free PCI or 4 PCIe slots!); hybrid configurations with CP 1613 A2 (PCI) and CP 1623 (PCIe) are possible, depending on PC expansion 4) without 4-way redundancy as there are only 2 slots 5) depending on the slots of the selected PC version Connection options of Industrial Ethernet CPs to PG/PC/IPC 5/186 Siemens ST 80 / ST PC · 2013 ○ - - • • • • • • • • • • • ○ 2) Notes - Please always note the supplementary conditions for the specified SIMATIC NET products that you can view on the Internet pages shown below. - for further details on XP embedded, see http://support.automation.siemens.com/WW/view/en/21661049 - further details on system requirements and operating environments can be found in the Readme file of the communication products on the SIMATIC NET PC Software V8.1 CD - Updates and supplements to the catalog entries, as well as the above tables can be viewed at http://www.siemens.com/simatic-net/ik-info 2) • - suitable - not suitable ○ suitable under certain conditions *B,.B;;B 5 CP 1612 A2 (PCI 32 Bit) • • • • • • - • • • • • • • - • • • • • - • • • • • • • • • • - • • • • • • • • • • - • - © Siemens AG 2013 PC-based Automation Communication — Industrial Ethernet CP 1604 ■ Overview • PCI-104 module for connecting PCI-104 systems to PROFINET IO • Full/half duplex with autonegotiation • With Ethernet real-time ASIC ERTEC 400 • Integral 4-port real-time switch • Communication services: - PROFINET IO controller and/or PROFINET IO device - Support of IRT in motion control applications - Support of PROFIenergy functionality • High performance through direct memory access • Integration in network management systems through the support of SNMP • Comprehensive diagnostics possibilities for installation, start-up and operation of the module • Powerful configuration tools are included in delivery of module 7&3 8'3 31 053 23& 3*23 66 ,7 *B,.B;;B ,62 ■ Ordering data CP 1604 communications processor Order No. 6GK1160-4AA01 Connection board for CP 1604 PCI-104 card (32-bit) with ASIC ERTEC 400 for connecting PCI-104 systems to PROFINET IO with 4-port real-time switch (RJ45); incl. IO-Base software for PROFINET IO-Controller and NCM PC; single license for one installation, runtime software, software and electronic manual on CD-ROM, Class A, for 32-bit Windows XP Professional and Windows 7; other operating systems using DK-16xx PN IO Development Kit German/English CP 1604 Microbox Package Order No. Accessories 6GK1160-4AC00 Connection board for CP 1604 with four RJ45 sockets incl. connecting cable Power supply for CP 1604 6GK1160-4AP00 Redundant power supply for CP 1604 for operating the integral 4-port switch of the CP 1604 with the PC-104 system switched off; includes connecting cable Development Kit DK-16xx PN IO 6GK1160-4AU01 Package for implementing the CP 1604 in the SIMATIC Microbox PC; comprising the CP 1604, connection board, power supply and expansion racks for Microbox PC; for use with Development Kit DK-16xx PN IO; NCM PC Software Development Kit for CP 1616/CP 1604; driver and IO-Base software for CP 1616/CP 1604 as PN IO controller and PN IO device in source code for transfer to other PC-based operating systems; incl. executable sample code for SUSE Linux 10, Windows XP Professional and Windows 7 5 See http://www.siemens.com/ simatic-net/dk16xx IE TP Cord RJ45/RJ45 TP cable 4 x 2 with 2 RJ45 connectors • 0.5 m •1m •2m •6m • 10 m 6XV1870-3QE50 6XV1870-3QH10 6XV1870-3QH20 6XV1870-3QH60 6XV1870-3QN10 SCALANCE X204IRT 6GK5204-0BA00-2BA3 Managed Industrial Ethernet switches; isochronous real time, LED diagnostics, error signaling contact with SET button, redundant power supply 4 x 10/100 Mbit/s RJ45 ports ■ More information The DK-16xx PN IO development kit can be found on the Internet at: http://www.siemens.com/simatic-net/dk16xx Siemens ST 80 / ST PC · 2013 5/187 © Siemens AG 2013 PC-based Automation Communication — Industrial Ethernet CP 1616 ■ Overview 7&3 8'3 31 053 23& 3*23 66 ,7 *B,.B;;B ,62 • PCI module for connecting PCs and SIMATIC PGs/PCs to PROFINET IO (Universal Keyed 3.3 V and 5 V; 33 MHz/66 MHz; 32-bit, runs in 64-bit PCI-X systems) • Full/half duplex with autonegotiation • With Ethernet real-time ASIC ERTEC 400 • Integral 4-port real-time switch • Communication services: - PROFINET IO controller and/or PROFINET IO device - Support of IRT in motion control applications • High performance through direct memory access • Integration in network management systems through the support of SNMP • Comprehensive diagnostics possibilities for installation, start-up and operation of the module • Powerful configuration tools are part of the scope of delivery of the module ■ Ordering data CP 1616 communications processor 5 Order No. 6GK1161-6AA02 PCI Card (32 bit; 3.3/5 V universal keyed) with ASIC ERTEC 400 for connecting PCs to PROFINET IO with 4-Port-Real-Time-Switch (RJ45); incl. IO Base Software for PROFINET IO Controller and NCM PC; single license for one installation, runtime software, software and electronic manual on CD-ROM, Class A, for 32-bit Windows XP Professional and Windows 7; other operating systems via Development Kit DK-16xx PN IO; German/English Order No. Accessories Development Kit DK-16xx PN IO Software development kit for CP 1616/CP 1604; driver and IO-Base software for CP 1616/CP 1604 as PN IO controller and IO device in source code for transfer to other PC-based operating systems; including executable example code for SUSE Linux 10, Windows XP Professional and Windows 7 IE TP Cord RJ45/RJ45 TP cable 4 x 2 with 2 RJ45 connectors • 0.5 m •1m •2m •6m • 10 m 6XV1870-3QE50 6XV1870-3QH10 6XV1870-3QH20 6XV1870-3QH60 6XV1870-3QN10 SCALANCE X204IRT 6GK5204-0BA00-2BA3 Managed Industrial Ethernet switches; isochronous real time, LED diagnostics, error signaling contact with SET button, redundant power supply 4 x 10/100 Mbit/s RJ45 ports ■ More information The DK-16xx PN IO development kit can be found on the Internet at: http://www.siemens.com/simatic-net/dk16xx 5/188 Siemens ST 80 / ST PC · 2013 See http://www.siemens.com/ simatic-net/dk16xx © Siemens AG 2013 PC-based Automation Communication — Industrial Ethernet CP 1612 A2 ■ Overview • PCI card (32 bit; 33 MHz/66 MHz; 3.3 V/5 V Universal Key) for the connection of PG/PC to Industrial Ethernet • 1 x 10/100/1000 Mbit/s RJ45 port, electrical • Automatic data transmission rate detection (10/100/1000 Mbit/s), with autosensing and autocrossover function • Communication services via - PROFINET - ISO or TCP/IP transport protocol - PG/OP communication - S7 communication - Open communication (SEND/RECEIVE) • Designed for use in industrial environments • The appropriate OPC servers and configuration tools are included in the scope of supply of the respective communication software. 7&3 8'3 31 053 23& 3*23 66 ,7 *B,.B;;B ,62 ■ Ordering data CP 1612 A2 communications processor Order No. 6GK1161-2AA01 Software for designing secure IP-based VPN connections from a programming device/PC to network segments which are secured by SCALANCE S in bridge mode; Single license for 1 installation, runtime software (German/English), configuring tool (German/English) and electronic manual on CD-ROM (German/English/French/Italian/ Spanish) for 32-bit Windows, XP Professional + SP1, SP2, SP3; for 32/64-bit Windows 7 Ultimate/ Business SOFTNET PN IO Software for PROFINET IO Controller with OPC server and NCM PC, runtime software, software and electronic manual on CD-ROM, license key on USB flash drive, Class A PCI card (32 bit, 33 MHz/66 MHz; 3.3 V/5 V universal keyed) for connection to Industrial Ethernet (10/100/1000 Mbit/s) with RJ45 interface, incl. driver for 32-bit Windows XP Professional SP2/3, 2003 R2 Server SP2, Vista Business/ Ultimate SP1, Windows 2008 Server; German/English SOFTNET Security Client V4 Order No. SOFTNET-IE PN IO V8.2 6GK1704-1VW04-0AA0 For 32/64-bit: Windows 7 Professional/Ultimate; for 64-bit: Windows 2008 Server R2 German/English • Single License for one installation 5 6GK1704-1HW08-2AA0 SOFTNET PN IO Edition 2008 (V7.1) For 32-bit Windows XP Professional SP 2/3; Windows 2003 Server R2, SP2; Windows Vista Business/ Ultimate SP1; Windows 2008 Server; English/German • Single License for one installation 6GK1704-1HW71-3AA0 Software Update Service 6GK1704-1HW00-3AL0 For 1 year with automatic extension; requirement: current software version Upgrade • From Edition 2006 to SOFTNET PN IO Edition 2008 or V8.1 • From V6.0, V6.1, V6.2 or V6.3 to SOFTNET PN IO Edition 2008 or V8.1 6GK1704-1HW00-3AE0 6GK1704-1HW00-3AE1 Siemens ST 80 / ST PC · 2013 5/189 © Siemens AG 2013 PC-based Automation Communication — Industrial Ethernet CP 1612 A2 ■ Ordering data Order No. SOFTNET-IE PG for Industrial Ethernet Software for S7 and open communication, incl. OPC server, PG/OP communication, and NCM PC, runtime software, software and electronic manual on CD-ROM, license key on a USB stick, Class A Software for PG/OP communication, runtime software, software and electronic manual on CD-ROM, license key on USB flash drive, Class A SOFTNET-IE S7 V8.2 For 32/64-bit: Windows 7 Professional/Ultimate; for 64-bit: Windows 2008 Server R2; German/English • Single License for one installation SOFTNET-IE PG V8.2 For 32/64-bit: Windows 7 Professional/Ultimate; for 64-bit: Windows 2008 Server R2; German/English Up to 64 connections • Single License for one installation 6GK1704-1CW08-2AA0 For 32-bit Windows XP Professional SP2/3; Windows 2003 Server R2, SP2; Windows Vista Business/ Ultimate SP1; Windows 2008 Server; English/German Up to 64 connections • Single License for one installation 6GK1704-1CW71-3AA0 Software Update Service 6GK1704-1CW00-3AL0 For 1 year with automatic extension; requirement: current software version Upgrade • From Edition 2006 to Edition 2008 or V8.1 • From V6.0, V6.1, V6.2 or V6.3 to Edition 2008 or V8.1 6GK1704-1PW08-2AA0 SOFTNET-PG Edition 2008 (V7.1) for Industrial Ethernet SOFTNET S7 Edition 2008 (V7.1) for Industrial Ethernet 5 Order No. SOFTNET S7 for Industrial Ethernet 6GK1704-1CW00-3AE0 For 32-bit Windows XP Professional SP2/3; Windows 2003 Server R2, SP2; Windows Vista Business/ Ultimate SP1; Windows 2008 Server; English/German • Single License for one installation 6GK1704-1PW71-3AA0 Software update 6GK1704-1PW00-3AL0 For 1 year with automatic extension; requirement: current software version Upgrade • From Edition 2006 to Edition 2008 or V8.1 • From V6.0, V6.1, V6.2 or V6.3 to Edition 2008 or V8.1 6GK1704-1PW00-3AE0 6GK1704-1PW00-3AE1 IE TP Cord RJ45/RJ45 TP cable 4 x 2 with 2 RJ45 connectors • 0.5 m •1m •2m •6m • 10 m 6XV1870-3QE50 6XV1870-3QH10 6XV1870-3QH20 6XV1870-3QH60 6XV1870-3QN10 SOFTNET-S7 Lean Edition 2008 (V7.1) for Industrial Ethernet Software Update Service 6GK1706-0HB00-3AL0 Up to eight connections • Single License for one installation 6GK1704-1LW71-3AA0 For 1 year with automatic extension; requirement: current software version Software Update Service 6GK1704-1LW00-3AL0 6GK1704-1CW00-3AE1 SOFTNET-IE S7 Lean Edition V8.2 Up to eight connections • Single License for one installation 6GK1704-1LW08-2AA0 For 1 year with automatic extension; requirement: current software version Upgrade • From Edition 2006 to Edition 2008 or V8.1 • From V6.0, V6.1, V6.2 or V6.3 to Edition 2008 or V8.1 5/190 6GK1704-1LW00-3AE0 6GK1704-1LW00-3AE1 Siemens ST 80 / ST PC · 2013 Upgrade • From Edition 2006 and higher to Edition 2008, single license • From V6.0 to Edition 2008, single license 6GK1706-0HB00-3AE0 6GK1706-0HB00-3AE1 © Siemens AG 2013 PC-based Automation Communication — Industrial Ethernet CP 1613 A2 ■ Overview ■ Ordering data Order No. CP 1613 A2 communications processor 6GK1161-3AA01 PCI card (32-bit, 33 MHz/66 MHz; 3.3 V/5 V universal keyed) for connection to Industrial Ethernet (10/100 Mbit/s) with ITP and RJ45 connection over HARDNET-IE S7/ S7-1613 and S7-REDCONNECT, for operating system support see SIMATIC NET Software HARDNET-IE S7 for Industrial Ethernet Software for S7 and open communication, incl. PG/OP communication, OPC server and NCM PC; up to 120 connections, runtime software, software and electronic manual on CD-ROM, license key on USB stick, Class A; for CP 1613/CP 1613 A2/ CP 1623/CP 1628; HARDNET-IE S7 V8.2 7&3 8'3 31 053 23& 3*23 66 ,7 *B,.B;;B ,62 • PCI card (32 bit; 33 MHz/66 MHz; 3.3 V/5 V universal key) with microprocessor for connection of PG/PC to Industrial Ethernet with 10/100 Mbit/s Autosensing/Autonegotiation • Communication services using - Open IE communication via TCP/IP and UDP) - ISO transport protocol - PG/OP communication - S7 communication - Open communication (SEND/RECEIVE) • 15-pole ITP connection • RJ45 connection • Time synchronization • ISO and TCP/IP transport protocol onboard • SNMP-supported diagnostics • The appropriate OPC server and configuration tools are included in the respective scope of supply of the communication software For 32/64-bit: Windows 7 Professional/Ultimate; for 64-bit: Windows 2008 Server R2 German/English • Single License for one installation 6GK1716-1CB08-2AA0 S7-1613 Edition 2008 (V7.1) For 32-bit Windows XP Professional SP2/3; Windows 2003 Server R2, SP2; Windows Vista Business/ Ultimate SP1; Windows 2008 Server; English/German • Single License for one installation 6GK1716-1CB71-3AA0 Software Update Service 6GK1716-1CB00-3AL0 For 1 year with automatic extension; requirement: current software version Upgrade • S7-1613, Edition 2006 or higher, to S7-1613 Edition 2008 or HARDNET-IE S7 V8.1 • from S7-1613 V6.0, V6.1, V6.2 or V6.3 to S7-1613 Edition 2008 or HARDNET-IE S7 V8.1 5 6GK1716-1CB00-3AE0 6GK1716-1CB00-3AE1 IE TP Cord RJ45/RJ45 TP cable 4 x 2 with 2 RJ45 connectors • 0.5 m •1m •2m •6m • 10 m 1) 6XV1870-3QE50 6XV1870-3QH10 6XV1870-3QH20 6XV1870-3QH60 6XV1870-3QN10 also S5-compatible communication Siemens ST 80 / ST PC · 2013 5/191 © Siemens AG 2013 PC-based Automation Communication — Industrial Ethernet CP 1623 ■ Overview ■ Ordering data CP 1623 communications processor Order No. 6GK1162-3AA00 PCI Express x1 card for connection to Industrial Ethernet (10/100/1000 Mbit/s), with 2-port switch (RJ45) via HARDNET-IE S7/ S7-1613 and S7-REDCONNECT. For operating system support, see SIMATIC NET Software HARDNET-IE S7 for Industrial Ethernet Software for S7 and open communication, incl. PG/OP communication, OPC server and NCM PC; up to 120 connections, runtime software, software and electronic manual on CD-ROM, license key on USB stick, Class A; for CP 1613/CP 1613 A2/ CP 1623/CP 1628; HARDNET-IE S7 V8.2 7&3 8'3 31 053 23& 3*23 66 ,7 *B,.B;;B ,62 5 • PCI Express Card (PCIe x1) with an internal microprocessor for connection of PG/PC to Industrial Ethernet • 10/100/1000 Mbit/s (Autosensing/Autocrossover/Autonegotiation) • Integrated 2-port switch (2 x RJ45 connection) • Communications services via - Open IE communication (TCP/IP and UDP) - ISO transport protocol - PG/OP communication - S7 communication - Open communication (SEND/RECEIVE) • Time synchronization • ISO and TCP/IP transport protocol on board • Integration into network management systems through the support of SNMP (V1) • The appropriate OPC server and configuration tools are included in the scope of supply of the respective communication software. 5/192 Siemens ST 80 / ST PC · 2013 For 32/64-bit: Windows 7 Professional/Ultimate; for 64-bit: Windows 2008 Server R2 German/English • Single License for one installation 6GK1716-1CB08-2AA0 S7-1613 Edition 2008 (V7.1) For 32-bit Windows XP Professional SP2/3; Windows 2003 Server R2, SP2; Windows Vista Business/ Ultimate SP1; Windows 2008 Server; English/German • Single License for one installation 6GK1716-1CB71-3AA0 Software Update Service 6GK1716-1CB00-3AL0 For 1 year with automatic extension; requirement: current software version Upgrade • S7-1613, Edition 2006 or higher, to S7-1613 Edition 2008 or HARDNET-IE S7 V8.1 • from S7-1613 V6.0, V6.1, V6.2 or V6.3 to S7-1613 Edition 2008 or HARDNET-IE S7 V8.1 6GK1716-1CB00-3AE0 6GK1716-1CB00-3AE1 IE TP Cord RJ45/RJ45 TP cable 4 x 2 with 2 RJ45 connectors • 0.5 m •1m •2m •6m • 10 m 6XV1870-3QE50 6XV1870-3QH10 6XV1870-3QH20 6XV1870-3QH60 6XV1870-3QN10 © Siemens AG 2013 PC-based Automation Communication — Industrial Ethernet CP 1628 ■ Overview ■ Ordering data Order No. Communications processor CP 1628 1) 6GK1162-8AA00 PCI Express x1 card for connection to Industrial Etherne t (10/100/1000 Mbps), with 2-port switch (RJ45) and integrated security (firewall, VPN) via HARDNET-IE S7 and S7-REDCONNECT. For operating system support, see SIMATIC NET Software HARDNET S7 for Industrial Ethernet Software for S7 and open communication, incl. PG/OP communication, OPC server and NCM PC; up to 120 connections, runtime software, software and electronic manual on CD-ROM, license key on USB stick, Class A; for CP 1613/CP 1613 A2/ CP 1623/CP 1628; 7&3 8'3 31 053 23& 3*23 66 HARDNET-IE S7 V8.2 ,7 *B,.B;;B ,62 • PCI Express card (PCIe x1) with its own microprocessor and integrated 2-port switch (2 x RJ45 connection, 10/100/1000 Mbit/s) for the connection of a PG/PC to Industrial Ethernet • Integrated security mechanisms (e.g. Firewall, VPN) • ISO and TCP/IP transport protocol on board • Communications services via - Open IE communication (TCP/IP and UDP) - ISO transport protocol - PG/OP communication - S7 communication - Open communication (SEND/RECEIVE) • Integration into network management systems through the support of SNMP (V1/V3) For 32/64-bit: Windows 7 Professional/Ultimate; for 64-bit: Windows 2008 Server R2 German/English • Single license for one installation 6GK1716-1CB08-2AA0 Software Update Service 6GK1716-1CB00-3AL0 For one year with automatic extension; requirement: Current software version Upgrade • S7-1613, Edition 2006 or higher, to S7-1613 Edition 2008 or HARDNET-IE S7 V8.1 • from S7-1613 V6.0, V6.1, V6.2 or V6.3 to S7-1613 Edition 2008 or HARDNET-IE S7 V8.1 6GK1716-1CB00-3AE0 5 6GK1716-1CB00-3AE1 IE TP Cord RJ45/RJ45 TP cable 4 x 2 with 2 RJ45 connectors • 0.5 m •1m •2m •6m • 10 m 1) 6XV1870-3QE50 6XV1870-3QH10 6XV1870-3QH20 6XV1870-3QH60 6XV1870-3QN10 Shipment without individual export license is restricted to certain countries. Export to other countries requires an individual export license that must be applied for from BIS (Bureau of Industry and Security). Note: Check the current country list: http://support.automation.siemens.com/WW/view/en/66627157 ■ More information You will find more information on the topic of Industrial Security on the Internet at: http://www.siemens.com/industrialsecurity Siemens ST 80 / ST PC · 2013 5/193 © Siemens AG 2013 PC-based Automation Communication — Industrial Ethernet HARDNET-IE S7-REDCONNECT ■ Overview • For connecting PCs over redundant Industrial Ethernet to the SIMATIC S7-400H • Protected from communication failures arising from a fault in the double bus or in redundant rings • For redundant Layer 2 or Layer 3 Industrial Ethernet • Can also be implemented in non-redundant networks • No additional programming overhead for the PC and in H systems • The appropriate OPC server and configuration tools are included in the scope of supply of the respective communication software • Enhanced redundancy over 4-way communication (STEP 7 V5.1 + SP4 and higher) PC with 2 x CP 1613 A2/CP 1623/CP 1628 and HARDNET-IE S7-REDCONNECT Industrial Ethernet H CPU in single mode ET 200M PROFIBUS G_IK10_XX_10048 S7-400H System configuration for S7-REDCONNECT 7&3 8'3 31 053 23& 3*23 66 ,7 *B,.B;;B ,62 5 5/194 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation Communication — Industrial Ethernet HARDNET-IE S7-REDCONNECT ■ Ordering data Order No. HARDNET-IE S7-REDCONNECT Software for fail-safe S7 communication via redundant networks, incl. S7 OPC server, HARDNET-IE S7, runtime software, software and electronic manual on CD-ROM, license key on USB stick, Class A; For expansion from HARDNET-IE S7 to S7-REDCONNECT, single license for one installation, runtime software, software and electronic manual on CD-ROM, license key on USB stick, Class A; HARDNET-IE S7-REDCONNECT V8.2 For 32/64-bit: Windows 7 Professional/Ultimate; for 64-bit: Windows 2008 Server R2 German/English • Single License for one installation Order No. HARDNET-IE S7-REDCONNECT Power Pack HARDNET-IE S7-REDCONNECT Power Pack V8.2 6GK1716-0HB08-2AA0 For 32/64-bit: Windows 7 Professional/Ultimate; for 64-bit: Windows 2008 Server R2; German/English; S7-REDCONNECT Edition 2008 (V7.1) S7-REDCONNECT Power Pack Edition 2008 (V7.1) For 32-bit Windows XP Professional SP 2/3; Windows 2003 Server R2, SP2; Windows Vista Business/Ultimate SP1; Windows 2008 Server; English/German • Single License for one installation For 32-bit Windows XP Professional SP 2/3; Windows 2003 Server R2, SP2; Windows Vista Business/ Ultimate SP1; Windows 2008 Server; English/German 6GK1716-0HB71-3AA0 Software Update Service 6GK1716-0HB00-3AL0 For 1 year with automatic extension; requirement: current software version Upgrade • From Edition 2006 to S7-REDCONNECT Edition 2008 or V8.1 • From V6.0, V6.1, V6.2 or V6.3 to S7-REDCONNECT Edition 2008 or V8.1 6GK1716-0HB00-3AE0 6GK1716-0HB00-3AE1 6GK1716-0HB08-2AC0 CP 1613 A2 communications processor 6GK1716-0HB71-3AC0 6GK1161-3AA01 PCI card (32-bit, 33 MHz/66 MHz; 3.3 V/5 V universal keyed) for connection to Industrial Ethernet (10/100 Mbit/s) with ITP and RJ45 connection over HARDNET-IE S7 and S7-REDCONNECT, for operating system support see SIMATIC NET Software CP 1623 communications processor 6GK1162-3AA00 PCI Express x1 card for connection to Industrial Ethernet (10/100/1000 Mbit/s), with 2-port switch (RJ45) via HARDNET-IE S7 and S7-REDCONNECT. For operating system support, see SIMATIC NET Software CP 1628 communications processor 5 6GK1162-8AA00 PCI Express x1 card for connection to Industrial Ethernet (10/100/1000 Mbit/s), with 2-port switch (RJ45) and integral security (firewall, VPN) via HARDNET-IE S7 and S7-REDCONNECT. For operating system support, see SIMATIC NET software Siemens ST 80 / ST PC · 2013 5/195 © Siemens AG 2013 PC-based Automation Communication — Industrial Ethernet SOFTNET for Industrial Ethernet ■ Overview zvm{ul{V ohykul{TplGz^GG plGz^GvwjGy zvm{ul{V ohykul{TplGz^GG plGz^GvwjGy • Software for coupling programming devices/workstations to automation systems • Communication services: - PG/OP communication - S7 communication - Open communication (SEND/RECEIVE) • Can be used with - Layer 2 Ethernet card (PCI/PCIe) - Integrated Industrial Ethernet interface, e.g. CP 1612 A2 - Modem (Remote Access Service RAS) • Complete protocol stack as a software package • Increased availability thanks to additional option packages such as OPC Server Redundancy otp p l S7-1200 G CSM 1277 nprXWXWW[\ z^TZWWGG jwGZ[ZTX z^T[WWGG jwG[[ZTX System configuration SOFTNET for Industrial Ethernet 7&3 8'3 31 053 23& 3*23 66 ,7 *B,.B;;B ,62 5 5/196 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation Communication — Industrial Ethernet SOFTNET for Industrial Ethernet ■ Ordering data Order No. Order No. SOFTNET S7 for Industrial Ethernet SOFTNET-PG for Industrial Ethernet Software for S7 and open communication, incl. OPC server, PG/OP communication, and NCM PC, runtime software, software and electronic manual on CD-ROM, license key on a USB stick, Class A Software for PG/OP communication, runtime software, software and electronic manual on CD-ROM, license key on USB flash drive, Class A SOFTNET-IE S7 V8.2 For 32/64-bit: Windows 7 Professional/Ultimate; for 64-bit: Windows 2008 Server R2; German/English • Single License for one installation SOFTNET-IE PG V8.2 For 32/64-bit Windows 7 Professional/Ultimate; for 64-bit: Windows 2008 Server R2; German/English Up to 64 connections • Single License for one installation 6GK1704-1CW08-2AA0 SOFTNET-S7 Edition 2008 (V7.1) for Industrial Ethernet For 32-bit Windows XP Professional SP2/3; Windows 2003 Server R2, SP2; Windows Vista Business/Ultimate SP1; Windows 2008 Server; English/German Up to 64 connections • Single License for one installation 6GK1704-1CW71-3AA0 Software Update Service 6GK1704-1CW00-3AL0 Upgrade • From Edition 2006 to Edition 2008 or V8.2 • From V6.0, V6.1, V6.2 or V6.3 to Edition 2008 or V8.1 6GK1704-1CW00-3AE0 6GK1704-1CW00-3AE1 SOFTNET-IE S7 REDCONNECT VM V8.2 Software for fail-safe S7 communication via redundant networks, incl. S7 OPC server, HARDNET-IE S7, runtime software, software and electronic manual on CD-ROM, license key on USB stick, Class A for 32/64-bit: Windows 7 Professional/Ultimate; for 64-bit: Windows 2008 Server R2; German/English; • Single License for one installation For 32-bit Windows XP Professional SP2/3; Windows 2003 Server R2, SP2; Windows Vista Business/ Ultimate SP1; Windows 2008 Server; English/German • Single License for one installation 6GK1704-1PW71-3AA0 Software update 6GK1704-1PW00-3AL0 For 1 year with automatic extension; requirement: current software version 6GK1704-1PW00-3AE0 6GK1704-1PW00-3AE1 IE S7 OPC Redundancy Software for redundant OPC servers in the environment of Industrial Ethernet software, S7 products, runtime software, software and electronic manual on CD-ROM, license key on USB flash drive, Class A 5 IE S7 OPC Redundancy V8.2 6GK1704-0HB08-2AA0 SOFTNET-IE S7 Lean Edition V8.2 Up to eight connections • Single License for one installation SOFTNET-PG Edition 2008 (V7.1) for Industrial Ethernet Upgrade • From Edition 2006 to Edition 2008 or V8.1 • From V6.0, V6.1, V6.2 or V6.3 to Edition 2008 or V8.1 For 1 year with automatic extension; requirement: current software version 6GK1704-1PW08-2AA0 For 64-bit: Windows 2008 Server R2; German/English • Single License for one installation • Software Update Service for one year, with automatic extension; requirement: current software version 6GK1706-1CW08-2AA0 6GK1706-1CW00-3AL0 6GK1704-1LW08-2AA0 SOFTNET-S7 Lean Edition 2008 (V7.1) for Industrial Ethernet Up to eight connections • Single License for one installation 6GK1704-1LW71-3AA0 Software Update Service 6GK1704-1LW00-3AL0 For 1 year with automatic extension; requirement: current software version Upgrade • From Edition 2006 to Edition 2008 or V8.1 • From V6.0, V6.1, V6.2 or V6.3 to Edition 2008 or V8.1 6GK1704-1LW00-3AE0 6GK1704-1LW00-3AE1 Siemens ST 80 / ST PC · 2013 5/197 © Siemens AG 2013 PC-based Automation Communication — Industrial Ethernet SOFTNET-IE RNA ■ Overview ■ Ordering data Order No. SOFTNET-IE RNA Software for connecting PCs to PRP-enabled networks with integrated SNMP, runtime software, software and electronic manual on CD-ROM, license key on USB flash drive, Class A SOFTNET-IE RNA V8.1 For 32-bit Windows XP; German/English • Single License for one installation 6GK1711-1EW08-1AA0 SOFTNET-IE RNA V8.2 • SOFTNET-IE RNA (Redundant Network Access is the software for connecting a PC to networks with PRP (Parallel Redundancy Protocol in accordance with IEC62439-3) capability • High level of plant availability thanks to duplicate transmission of frames in two parallel, separate networks • Reconfiguration times in a subnetwork do not affect the propogation time because the frames are transmitted via two separate networks (bumpless redundancy) • Integration in network management systems through support for SNMP • Configuring tools are included in the scope of delivery of the communication software in each case Industrial Ethernet (LAN A) Industrial Ethernet (LAN B) SIPROTEC SIMATIC S7-400 with CP 443-1RNA 5/198 Siemens ST 80 / ST PC · 2013 SCALANCE X204RNA PC G_IK10_XX_10333 5 Server with SOFTNET-IE RNA PG/PC/IPC with SOFTNET-IE RNA For 32/64-bit Windows 7 Professional/Ultimate; for 64-bit Windows 2008 Server R2; German/English • Single License for one installation 6GK1711-1EW08-2AA0 Software Update Service 6GK1711-1EW00-3AL0 For 1 year with automatic extension; requirement: current software version SCALANCE X-200RNA Industrial Ethernet network access points Industrial Ethernet network access points with integrated SNMP access, web diagnostics and PROFINET diagnostics, for connecting non-PRP-enabled terminal equipment to PRP networks; incl. operating instructions, Industrial Ethernet network manual and configuration software on CD-ROM; with electrical and optical ports for glass multimode fiber-optic cable up to 5 km • SCALANCE X204RNA with four 100 Mbit/s RJ45 ports • SCALANCE X204RNA EEC with two 100 Mbit/s RJ45 ports and two RJ45/SFP combo ports 6GK5204-0BA00-2KB2 6GK5204-0BS00-3LA3 © Siemens AG 2013 PC-based Automation Communication — Industrial Ethernet SOFTNET PN IO ■ Overview SIMATIC NET OPC-Scout PC/IPC with SOFTNET PN IO WinCC OPC-Client OPC UA Microsoft Office OPC-Client OPC XML Webclient COM/DCOM Internet Intranet OPC XML DA as Webservice PN IO OPC-Server PROFINET Communication SOFTNET PN IO PROFINET Industrial Ethernet IE/PB Link PN IO ET 200pro ET 200S with IM 151-3 PN G_IK10_XX_10073 PROFIBUS e.g. S7-300 with CPU 31x and CP 343-1 e. g. S7-300 with CP 342-5 as Slave ET 200S PC with SOFTNET PN IO as PROFINET IO Controller 7&3 8'3 31 053 23& 3*23 66 ,7 *B,.B;;B ,62 • Software with PROFINET IO Controller function for coupling PG/PC and IPC with PROFINET IO Devices • Possible applications: - PC-based control systems - HMI systems - Test applications • Communication services: - PROFINET IO Controller • Can be used with - Integrated interfaces of SIMATIC PG/PC - You can find more information about the environment of use at www.siemens.com/simatic-net/ik-info • Cost-effective solution for the low-end performance range • OPC server for I/O interfacing over PROFINET included in scope of supply Siemens ST 80 / ST PC · 2013 5/199 5 © Siemens AG 2013 PC-based Automation Communication — Industrial Ethernet SOFTNET PN IO ■ Ordering data Order No. Order No. SOFTNET PN IO Software Update Service Software for PROFINET IO Controller with OPC server and NCM PC, runtime software, software and electronic manual on CD-ROM, license key on USB flash drive, Class A For 1 year with automatic extension; requirement: current software version Upgrade • From Edition 2006 to SOFTNET PN IO Edition 2008 or V8.1 • From V6.0, V6.1, V6.2 or V6.3 to SOFTNET PN IO Edition 2008 or V8.1 SOFTNET-IE PN IO V8.2 For 32/64-bit: Windows 7 Professional/Ultimate; for 64-bit: Windows 2008 Server R2 German/English • Single License for one installation 6GK1704-1HW08-2AA0 SOFTNET PN IO Edition 2008 (V7.1) For 32-bit Windows XP Professional SP 2/3; Windows 2003 Server R2, SP2; Windows Vista Business/ Ultimate SP1; Windows 2008 Server; German/English • Single License for one installation 6GK1704-1HW71-3AA0 5 5/200 Siemens ST 80 / ST PC · 2013 6GK1704-1HW00-3AL0 6GK1704-1HW00-3AE0 6GK1704-1HW00-3AE1 © Siemens AG 2013 PC-based Automation Communication — Industrial Ethernet OPC server for Industrial Ethernet ■ Overview PC/Windows PC SIMATIC NET OPC-Scout WinCC OPC-Client Microsoft Office OPC-Client OPC XML Webclient OPC UA COM/DCOM DP OPC server FMS OPC server S7 OPC server Internet Intranet S/R OPC server PN IO OPC server SNMP OPC server OPC XML DA as Web service DP protocol FMS protocol S7 communication Open communication (SEND/RECEIVE) PROFINET SNMP PROFINET Industrial Ethernet S7-1200 S7-1200 PC S7-400 S7-300 SIMATIC S5 (SEND/RECEIVE only) ET 200pro 5 PC PROFIBUS G_IK10_XX 10103 SIMATIC S5 System integration with OPC server OPC (Openness, Productivity & Collaboration) is a standardized, open, and vendor-independent interface that is widely used in automation. A fundamental distinction is made between the classic OPC and its consistent further development OPC UA (Unified Architecture). Smooth migration to the new OPC UA standard is easily possible; this offers further value added, such as security. The SIMATIC NET OPC servers offer the two interfaces OPC UA and classic OPC for SIMATIC S7 and PROFINET. • The appropriate OPC servers are included in the scope of supply of the respective communication software • Standardized, open multi-vendor interface • It permits interfacing of OPC-capable Windows applications to S7-communication, open communication (SEND/RECEIVE), PROFINET and SNMP. • Increased availability thanks to additional option packages such as OPC server redundancy • OPC Scout with browser functionality as an OPC client and OCX Data Control/.NET Data Control for simple OPC client creation Siemens ST 80 / ST PC · 2013 5/201 © Siemens AG 2013 PC-based Automation Communication — Industrial Ethernet OPC server for Industrial Ethernet ■ Ordering data SNMP OPC server Order No. See SNMP OPC server Status monitoring of SNMP-capable devices in any OPC client systems; e.g. SIMATIC WinCC/PCS 7 Order No. S7 OPC Redundancy Software for redundant OPC servers in the environment of Industrial Ethernet software, S7 products, runtime software, software and electronic manual on CD-ROM, license key on USB flash drive, Class A S7 OPC Redundancy V8.2 For 64-bit: Windows 2008 Server R2; German/English • Single License for one installation 6GK1706-1CW08-2AA0 Software Update Service 6GK1706-1CW00-3AL0 For 1 year with automatic extension; requirement: current software version 5 5/202 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation Communication — Industrial Ethernet PN CBA OPC server ■ Overview WinCC flexible OPC client SOFTNET-S7 SOFTNET-S7 Lean S7-1613 Microsoft Office OPC client PN CBA OPC-Server SIMATIC NET OPC Scout SOFTNET PN IO S7-OPC-Server PN CBA OPC-Server PN IO OPC-Server S7 communication PROFINET CBA PROFINET IO PROFINET Industrial Ethernet PROFINET CBA component PROFINET IO Devices e.g. S7-300 with CP 343-1 and CP 343-5 ET 200pro IE/PB Link PN IO e.g. S7-400 with CP 443-1 Advanced ET 200S PROFIBUS DP S7-300 with CP 343-1, IPC with CP 343-1 Lean CP 1616/ CP 343-1 CP 1604 ET 200S PROFINET IO Device Data access Data access via PROFIBUS DP from viewpoint of PN CBA OPC server 5 PROFIBUS DP ET 200S from viewpoint of PN IO OPC server G_IK10_XX_10122 PROFINET CBA component System integration with the PN CBA OPC server • Access to variables in PROFINET CBA components over the OPC interface • Use of the objects and symbols defined using the PROFINET engineering tool SIMATIC iMap and STEP 7 • Adding PROFINET functionality to existing installations. This enables it to be used in parallel with other communication protocols such as S7 communication with SOFTNET-S7 for Industrial Ethernet. • OPC Scout as an OPC client with browser functions for the variables of the PROFINET CBA components Siemens ST 80 / ST PC · 2013 5/203 © Siemens AG 2013 PC-based Automation Communication — Industrial Ethernet PN CBA OPC server ■ Ordering data Order No. PROFINET OPC server for CBA; runtime software, software and electronic manual on CD-ROM, license key on USB flash drive, Class A, for 32-bit Windows XP Professional SP 2/3; Windows 2003 Server R2, SP2; German/English • Single license for one installation • Software Update Service for one year, with automatic extension; requirement: Current software version • Upgrade from Edition 2006 and higher to Edition 2008, single license • Upgrade from V6.0, V6.1, V6.2 or V6.3 to Edition 2008, Single License 6GK1706-0HB71-3AA0 6GK1706-0HB00-3AL0 6GK1706-0HB00-3AE0 6GK1706-0HB00-3AE1 Software iMap V3.0 for configuring PROFINET CBA Requirement: Windows 2000 Prof. with Service Pack 4 or later or Windows XP Prof. with Service Pack 1 or later or Windows 2003 Server with Service Pack 1 or later; on PG or PC with Pentium processor, min. 1 GHz; STEP 7 V5.3 or later with Service Pack 3, PN OPC Server V6.3 or later 5 Type of supply: German, English with electronic documentation • Single license • Software Update Service • Upgrade to V3.0, single license 5/204 ■ More information http://www.siemens.com/cba PN CBA OPC Server Edition 2008 6ES7820-0CC04-0YA5 6ES7820-0CC01-0YX2 6ES7820-0CC04-0YE5 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 PC-based Automation Communication — Industrial Ethernet S7 OPC Redundancy for Industrial Ethernet ■ Overview ■ Ordering data OPC (Openness, Productivity & Collaboration) is a standardized, open, and vendor-independent interface that is widely used in automation. OPC UA (Unified Architecture) is the result of consistent further development of this standard, offering additional functions such as security or redundancy. S7 OPC Redundancy is a software product compliant with the OPC UA standard that enables the redundant configuration of OPC UA servers to SIMATIC S7. The availability of automation data to operator control and monitoring systems is guaranteed thanks to the redundant use of OPC UA servers. This requires neither additional cabling for synchronizing the redundant OPC UA servers, nor additional programming overhead in the PC. The OPC UA servers are synchronized via high-performance Industrial Ethernet network access points at 10/100 and 1000 Mpbs. S7 OPC Redundancy represents an integrated customer solution for all SIMATIC NET S7 SOFTNET and HARDNET software products in the automation world. Order No. S7 OPC Redundancy Software for redundant OPC servers in the environment of Industrial Ethernet software, S7 products, runtime software, software and electronic manual on CD-ROM, license key on USB flash drive, Class A S7 OPC Redundancy V8.2 for Industrial Ethernet For 64-bit: Windows 2008 Server R2; German/English • Single License for one installation 6GK1706-1CW08-2AA0 Software Update Service 6GK1706-1CW00-3AL0 For 1 year with automatic extension; requirement: current software version HMI Industrial Ethernet S7 OPC redundancy S7 OPC redundancy OPC UA synchronization Station A 5 Station B Industrial Ethernet G_IK10_XX_10295 PROFIBUS Siemens ST 80 / ST PC · 2013 5/205 © Siemens AG 2013 PC-based Automation Communication — Industrial Ethernet SNMP OPC server ■ Overview Pumpstation Network Pump Main 1GBit Pump Old ■ Ordering data Order No. Order No. SNMP OPC server SNMP OPC Server Extended Including MIB compiler; single license for one installation of runtime software; software and electronic manual on CD-ROM; license key on USB stick, Class A; Administration of up to 200 IP addresses • Extended V8.2 for 32/64-bit: Windows 7 Professional/Ultimate; for 64-bit: Windows 2008 Server R2; Single license for one installation • Extended 2008 (V7.1) for 32-bit Windows XP Professional SP2/3; Windows 2003 Server R2, SP2; Windows Vista Business/Ultimate SP1; Windows 2008 Server; Single license for one installation SNMP OPC Server Basic 5 S_IK10_XX_00004 Pump Substation 1 • Status monitoring of SNMP-capable devices in any OPC client systems; e.g. SIMATIC WinCC/PCS 7 • Easy access to SNMP-capable devices over the OPC interface • Devices without SNMP agents can be monitored using the ping mechanism • Configuring with STEP 7 or NCM PC • Ready-to-use SNMP diagnostics profiles for Siemens devices, e.g. SCALANCE X/W • Generation of any SNMP diagnostics profiles by means of the integral MIB compiler • Easy setup of the monitored devices with the help of an autodiscovery function Administration of up to 20 IP addresses • Basic V8.2 for 32/64-bit: Windows 7 Professional/Ultimate; for 64-bit: Windows 2008 Server R2; Single license for one installation • Basic 2008 (V7.1) for 32-bit Windows XP Professional SP2/3; Windows 2003 Server R2, SP2; Windows Vista Business/Ultimate SP1; Windows 2008 Server; Single license for one installation Software Update Service SNMP OPC Server Basic 6GK1706-1NW08-2AA0 6GK1706-1NW71-3AA0 5/206 6GK1706-1NX71-3AA0 6GK1706-1NX00-3AL0 For 1 year with automatic extension; requirement: current software version 6GK1706-1NW00-3AL0 For 1 year with automatic extension; requirement: current software version Upgrade SNMP OPC Server Basic • From Edition 2006 to Edition 2008 or V8.1 • From V6.0, V6.1, V6.2 or V6.3 to Edition 2008 or V8.1 Software Update Service SNMP OPC Server Extended 6GK1706-1NX08-2AA0 Upgrade SNMP OPC Server Extended • From Edition 2006 to Edition 2008 or V8.1 • From V6.0, V6.1, V6.2 or V6.3 to Edition 2008 or V8.1 6GK1706-1NX00-3AE0 6GK1706-1NX00-3AE1 SNMP OPC Server Power Pack 6GK1706-1NW00-3AE0 6GK1706-1NW00-3AE1 Siemens ST 80 / ST PC · 2013 For upgrade from SNM OPC Server Basic to SNM OPC Server Extended Power Pack V8.2 6GK1706-1NX08-2AC0 Power Pack Edition 2008 (V7.1) 6GK1706-1NX71-3AC0 © Siemens AG 2013 PC-based Automation Communication — Industrial Ethernet SINEMA server ■ Overview ■ Ordering data Order No. SINEMA Server Basic V12 SINEMA Server is a web-based network monitoring software that significantly reduces the response time to communications problems in industrial networks, and thus avoids downtimes and saves costs. • Simple operator input even for plant operators or service personnel, to enable autonomous detection and correction of communications problems • Graphical representation of industrial networks (automatic topology detection and layout) • Standardized network documentation (reports for inventory, availability and utilization) • Simple operation via web browser or via an HMI/SCADA application, without special IT knowledge • Network data such as network topology and device information automatically saved to a database • Low installation and maintenance costs, especially thanks to the use of pre-installed industrial PCs (Microbox PC) • High degree of flexibility for graphical representation thanks to automatic and customizable topology views • Monitoring can be adapted to devices and users Network monitoring software for industrial Ethernet and PROFINET networks, runtime software, software and electronic manual on DVD, license key on USB flash memory; software for installation on PC hardware with Windows 7 Ultimate/ Enterprise SP1 (32/64-bit), Windows XP SP3 (32-bit) and Windows Server 2008 R2 (64-bit); English/German/French/Chinese. Other languages possible on request. • For 50 devices that can be identified via IP address • For 100 devices that can be identified via IP address • For 250 devices that can be identified via IP address • For 500 devices that can be identified via IP address Upgrade SINEMA Server V11 to V12 6GK1781-1BA12-0AA0 6GK1781-1DA12-0AA0 6GK1781-1JA12-0AA0 6GK1781-1TA12-0AA0 6GK1781-2AA12-0AA0 5 Siemens ST 80 / ST PC · 2013 5/207 © Siemens AG 2013 PC-based Automation Communication — PROFIBUS Connection options to SIMATIC IPCs ■ Overview Embedded Systems Windows XP Pro + SP3 Windows Server 2003 + SP1/2 Windows Server 2003 R2 / SP2 other operating systems Field PG M3 SIMATIC IPC847C SIMATIC IPC647C SIMATIC IPC547C, SIMATIC HMI IPC577D SIMATIC IPC627C SIMATIC IPC827C SIMATIC IPC427C Windows XP Embedded + SP1/SP2/FP 2007 SIMATIC IPC427C SIMATIC HMI IPC477C SIMATIC HMI IPC677C SIMATIC IPC627C SIMATIC S7 modular Embedded Controller SIMATIC Industrial PCs 3) Vista Business / Ultimate + SP1/2 Op. sys. Windows Server 2008 + SP1/2 SIMATIC Industrial PC/ Field PG Windows Server 2008 R2 Operating system environment of the communication software Windows 7 Professional / Ultimate Communication Communication hardware software ● ○ ● ○ ● ○ ● ○ ● ○ ● ○ ● ○ ○ - - - - - - ● ○ ● ○ ● ○ ● ○ - - ○5) ● ● ● ● ● ● ● - - - - - - - ● ● ● ● - - - ● ● ● ● ● ● ● - - - - - - - ● ● ● ● - - - ● ○ ● ● ○ ● ○ ● ○ ● ○ ● ○ ● ○ ○ - ● ○ ● ○ ● ○ ● ○ ● ○ ● - ● ○ ● - ● - ● ○ ● ○ - ● ● ● ● ● ● ● - - ● ● ● ● ● - - - - ● ● - ● ● ● ● ● ● ● - - ● ● ● ● ● - - - - ● ● - ● ○ ● ● ○ ● ○ ● ○ ● ○ ● ○ ● ○ ○ - ● ●4) ○ ● - ● ● ○ ● ○4) ○ ● ● ○ - ○ - - ● ● ○4) ○4) ○4) ○4) - ● ● ● ● ● ● ● - - ●4) - ● ○4) ● - - - - ○4) ○4) - ● ● ● ● ● ● ● - - ● - ● ○ ● - - - - ○ ○ - ● ● ● ● ● ● ● ● ● ● ● ● - ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● - ● ● ● ● ● ● ● ● ● - ● ● ● ● ● ● ● ● ● - ● ● ● ● ● ● ● ● ● - ● ● ● ● ● ● ● ● ● - - ● ● ● ● ● ● ● ● ● ● ● ●4) ● ● ● ● ●4) ●4) ●4) ●4) ● ● ● ● ○2) ○2) ○2) ○2) ● ● ● ● ● ● ● ● ○2) ○2) ○2) ○2) ● ● ● ● ● ● ● ● ● ● ● ● ● - ○4) ● ● ● ● ○4) ○4) ○4) ○4) ● ● ● ● ○2) ○2) ○2) ○2) ● ● ● ● ● ● ● ● ● ● ● ● ● ○2) ○2) ○2) ○2) ● ● ● ● ○2) ○2) ○2) ○2) ● ● ● ● ● ● ● ● ● ● ● ● ○2) ○2) ○2) ○2) ● ● ● ● ● ● ● ● ○4) ● ● ● ● ○4) ○4) ○4) ○4) ● ● ● ● ○2) ○2) ○2) ○2) ○4) ● ● ● ● ○4) ○4) ○4) ○4) ● ● ● ● ○2) ○2) ○2) ○2) ● ● ● ● - • suitable CP with DP-Base CP 5603 (PCI-104) HARDNET-PB DP DK 1) (DK-5613, DP-base) HARDNET-PB DP (DP-5613) HARDNET-PB S7 (S7-5613) S7 OPC Redundancy for PROFIBUS CP mit DP-Base CP 5613 A2, CP 5614 A2 (PCI 32 Bit) HARDNET-PB DP DK 1) (DK-5613, DP-base) HARDNET-PB DP (DP-5613) HARDNET-PB S7 (S7-5613) S7 OPC Redundancy for PROFIBUS CP with DP-Base CP 5623, CP 5624 (PCIe x1) 5 HARDNET-PB DP DK 1) (DK-5613, DP-base) HARDNET-PB DP (DP-5613) HARDNET-PB S7 (S7-5613) S7 OPC Redundancy for PROFIBUS SOFTNET-PB DP CP 5612 (PCI 32 Bit) SOFTNET-PB DP Slave SOFTNET-PB S7 S7 OPC Redundancy for PROFIBUS SOFTNET-PB DP CP 5622 (PCIe x1) SOFTNET-PB DP Slave SOFTNET-PB S7 S7 OPC Redundancy for PROFIBUS CP 5512 (Cardbus 32 Bit) SOFTNET-PB DP CP 5711 (USB V2.0) SOFTNET-PB DP SOFTNET-PB DP Slave SOFTNET-PB S7 SOFTNET-PB DP Slave SOFTNET-PB S7 S7 OPC Redundancy for PROFIBUS SIMATIC PG/PC SOFTNET-PB DP SOFTNET-PB DP Slave SOFTNET-PB S7 S7 OPC Redundancy for PROFIBUS 1) In order to use these CPs in other operating system environments, it is required to port HARDNET DP Development Kits (DK-5613) into the respective operating system. You can request the HARDNET DP DK in the Internet under www.siemens.com/simatic-net/dk5613. 2) integrated PROFIBUS interface is optional 3) depending on available memory and processor performance there could be restrictions 4) depending on the slots of the selected PC version 5) EM-PCI 104 expansion module is required Siemens ST 80 / ST PC · 2013 4) Notes - Please always note the supplementary conditions for the specified SIMATIC NET products that you can view on the Internet pages shown below. - for further details on XP embedded, see http://support.automation.siemens.com/WW/view/en/21661049 - further details on system requirements and operating environments can be found in the Readme file of the communication products on the SIMATIC NET PC Software CD V8.1 - Updates and supplements to the catalog entries, as well as the above tables can be viewed at http://www.siemens.com/simatic-net/ik-info Connection options of PROFIBUS CPs to PG/PC Note: The operating systems listed refer exclusively to the communication products specified! 5/208 4) 4) 4) - not suitable ○ suitable under certain conditions *B,.B;;B CPs and software for Industrial Ethernet For the actual operating system that is available and has been released, please refer to the description of the corresponding IPC. © Siemens AG 2013 PC-based Automation Communication — PROFIBUS CP 5603 ■ Overview ■ Ordering data Order No. CP 5603 communications processor 6GK1560-3AA00 PCI-104 card for connection to PROFIBUS incl. DP-Base software with NCM PC; DP-RAM interface for DP master or DP slave, incl. PG and FDL protocols; single license for one installation, runtime software, software and electronic manual on CD-ROM, Class A, for operating system support see SIMATIC NET software; German/English Software Upgrade 6GK1561-3AA01-3AE0 For CP 5603, CP 5613 A2 and CP 5623 to Edition 2008 or V8.1 CP 5603 Microbox Package 6GK1560-3AU00 For use of CP 5603 in Microbox 420/427B/427C; consisting of CP 5603 module and Microbox expansion frame '36 )06 23& 3*23 CP 5603 expansion rack 66 *B,.B;;B '30 • PCI-104 interface card with own microprocessor for connecting embedded systems with PCI-104 interface to PROFIBUS at up to 12 Mbit/s • Function compatible with CP 5613 A2 • Communication services: - PROFIBUS DP master Class 1 and 2 or DP slave according to IEC 61158/61784 - PG/OP communication with STEP 5 and STEP 7 - S7 communication with HARDNET-PB S7 software package - Open communication (SEND/RECEIVE) based on the FDL interface - PROFIBUS FMS according to IEC 61158/61784 with FMS-5613 software package • Extensive diagnostics options for installation, commissioning and operation of the module • Event and filter mechanism for reducing the load on the host CPU • Multiprotocol operation and parallel operation of up to three CPs • The appropriate OPC server and configuration tools are included in the scope of delivery of the respective communication software • Linux-based development kit with driver sources for integration into "non-Windows" environments 6GK1560-3AA00-0AU0 For use in Microbox 420/427B/427C with mounting material CP 5603 mEC Package 6GK1560-3AE00 For use of CP 5603 in SIMATIC S7-MEC; consisting of CP 5603 and withdrawable unit for CP 5603 for installation in the EM PCI-104 expansion module of the SIMATIC S7-MEC CP 5603 insert plate 6GK1560-3AA00-0AE0 Metal plate with RS485 cutout for inserting for the S7 modular embedded controller See http://www.siemens.com/ simatic-net/dk5613 HARDNET-PB DP Development Kit HARDNET-PB DP Development Kit software for CP 5603, CP 5613, CP 5613 A2, CP 5623, CP 5613 FO, CP 5614, CP 5614 A2, CP 5624; for integration into other operating system environments on systems with a PCI slot Siemens ST 80 / ST PC · 2013 5/209 5 © Siemens AG 2013 PC-based Automation Communication — PROFIBUS CP 5603 ■ Ordering data Order No. Software Update Service Software for DP, incl. PG and FDL protocol, OPC server and NCM PC; runtime software, software and electronic manual on CD-ROM, license key on USB flash drive, Class A, for CP 5603, CP 5613 A2, CP 5623, CP 5614 A2, CP 5624; For 1 year with automatic extension; requirement: current software version Upgrade • From Edition 2006 or 2007 to S7-5613 Edition 2008 or HARDNET-PB S7 V8.1 • From V6.0, V6.1, V6.2 or V6.3 to S7-5613 Edition 2008 or HARDNET-PB S7 V8.1 HARDNET-PB DP V8.2 For 32/64-bit: Windows 7 Professional/Ultimate; for 64-bit: Windows 2008 Server R2 German/English • Single License for one installation 6GK1713-5DB08-2AA0 For 32-bit Windows XP Professional SP2/3; Windows 2003 Server R2, SP2; Windows Vista Business/ Ultimate SP1; Windows 2008 Server; English/German • Single License for one installation 6GK1713-5DB71-3AA0 Software Update Service 6GK1713-5DB00-3AL0 For 1 year with automatic extension; requirement: current software version Upgrade • From Edition 2006 or 2007 to DP-5613 Edition 2008 or HARDNET-PB DP V8.1 • From V6.0, V6.1, V6.2 or V6.3 to DP-5613 Edition 2008 or HARDNET-PB DP V8.1 6GK1713-5DB00-3AE0 6GK1713-5DB00-3AE1 HARDNET-PB S7 6GK1713-5FB71-3AA0 Software Update Service 6GK1713-5FB00-3AL0 For 1 year with automatic extension; requirement: current software version Upgrade • From Edition 2006 or 2007 to FMS-5613 Edition 2008 • From V6.0, V6.1, V6.2 or V6.3 to FMS-5613 Edition 2008 PROFIBUS FastConnect bus connector RS485 Plug 180 6GK1713-5FB00-3AE0 6GK1713-5FB00-3AE1 6XV1830-0EH10 6GK1500-0FC10 With 180° cable outlet, insulation displacement PROFIBUS bus terminal 12M 6GK1713-5CB08-2AA0 S7-5613 Edition 2008 6GK1713-5CB71-3AA0 You can find the HARDNET-PB DP Development Kit on the Internet at: http://www.siemens.com/simatic-net/dk5613 Siemens ST 80 / ST PC · 2013 6GK1500-0AA10 Bus terminal for connection of PROFIBUS stations up to 12 Mbit/s with plug-in cable 1.5 m long PROFIBUS FastConnect Stripping Tool ■ More information 5/210 6GK1713-5CB00-3AE1 Standard type with special design for quick assembly, 2-core, shielded, sold in meters; delivery unit max. 1000 m, minimum order 20 m HARDNET-PB S7 V8.2 For 32-bit Windows XP Professional SP2/3; Windows 2003 Server R2, SP2; Windows Vista Business/ Ultimate SP1; Windows 2008 Server; English/German • Single License for one installation 6GK1713-5CB00-3AE0 Software for FMS protocol incl. PG/OP communication; FDL, FMS-OPC server and NCM PC; runtime software, software and electronic manual on USB stick, Class A, for 32-bit Windows XP Professional SP2/3; Windows 2003 Server R2, SP2; Windows Vista Business/ Ultimate SP1; Windows 2008 Server; for CP 5603, CP 5613, CP 5613 A2, CP 5623, CP 5613 FO, CP 5614, CP 5614 A2, CP 5624; German/English • Single License for one installation PROFIBUS FC Standard Cable GP Software for S7 communication, incl. PG and FDL protocol, OPC server and NCM PC; runtime software, software and electronic manual on USB flash drive, Class A, for CP 5603, CP 5613 A2, CP 5623, CP 5614 A2, CP 5624; For 32/64-bit: Windows 7 Professional/Ultimate; for 64-bit: Windows 2008 Server R2 German/English • Single License for one installation 6GK1713-5CB00-3AL0 FMS-5613 Edition 2008 DP-5613 Edition 2008 5 Order No. HARDNET-PB DP Preset stripping tool for fast stripping of PROFIBUS FastConnect bus cables 6GK1905-6AA00 © Siemens AG 2013 PC-based Automation Communication — PROFIBUS CP 5613 A2 ■ Overview ■ Ordering data Order No. CP 5613 A2 communications processor 6GK1561-3AA01 PCI card (32-bit; 3.3 V/5 V) for connection to PROFIBUS incl. DP-Base software with NCM PC; DP-RAM interface for DP master, incl. PG and FDL protocols; single license for one installation, runtime software, software and electronic manual on CD-ROM, Class A, for operating system support see SIMATIC NET software; German/English Software Upgrade 6GK1561-3AA01-3AE0 For CP 5603, CP 5613 A2 and CP 5623 to Edition 2008 or V8.1 See http://www.siemens.com/ simatic-net/dk5613 HARDNET-PB DP Development Kit '36 )06 23& 3*23 66 *B,.B;;B '30 • PCI card (universal keyed 5 V/3.3 V) with own microprocessor for connection of PCs and SIMATIC PG/PC to PROFIBUS at up to 12 Mbit/s • Communication services: - PROFIBUS DP master according to IEC 61158/61784 on a PCI card - PG/OP communication with STEP 5 and STEP 7 - S7 communication with HARDNET-PB S7 software package - Open communication (SEND/RECEIVE) based on the FDL interface - PROFIBUS FMS according to IEC 61158/61784 with FMS-5613 software package • Comprehensive diagnostics possibilities for installation, commissioning and operation of the module • High performance over direct dual-port RAM access • Event and filter mechanisms to reduce the loading on the host CPU • Multiprotocol operation and parallel operation of up to four CPs • Implementation in Motion Control applications is possible because a constant bus cycle time is supported • The appropriate OPC servers and configuration tools are included in the scope of supply of the respective communications software. HARDNET-PB DP Development Kit software for CP 5613/CP 5614/ CP 5613 A2/CP 5614 A2/ CP 5613 FO for integration into other operating system environments on systems with a PCI slot HARDNET-PB DP Software for DP, incl. PG and FDL protocol, OPC server and NCM PC; runtime software, software and electronic manual on CD-ROM, license key on USB flash drive, Class A, for CP 5603, CP 5613 A2, CP 5623, CP 5614 A2, CP 5624; HARDNET-PB DP V8.2 For 32/64-bit: Windows 7 Professional/Ultimate; for 64-bit: Windows 2008 Server R2 German/English • Single License for one installation 5 6GK1713-5DB08-2AA0 DP-5613 Edition 2008 For 32-bit Windows XP Professional SP2/3; Windows 2003 Server R2, SP2; Windows Vista Business/Ultimate SP1; Windows 2008 Server; English/German • Single License for one installation 6GK1713-5DB71-3AA0 Software Update Service 6GK1713-5DB00-3AL0 For 1 year with automatic extension; requirement: current software version Upgrade • From Edition 2006 or 2007 to DP-5613 Edition 2008 or HARDNET-PB DP V8.1 • From V6.0, V6.1, V6.2 or V6.3 to DP-5613 Edition 2008 or HARDNET-PB DP V8.1 6GK1713-5DB00-3AE0 6GK1713-5DB00-3AE1 Siemens ST 80 / ST PC · 2013 5/211 © Siemens AG 2013 PC-based Automation Communication — PROFIBUS CP 5613 A2 ■ Ordering data Order No. Software Update Service Software for S7 communication, incl. PG and FDL protocol, OPC server and NCM PC; runtime software, software and electronic manual on USB flash drive, Class A, for CP 5603, CP 5613 A2, CP 5623, CP 5614 A2, CP 5624; For 1 year with automatic extension; requirement: current software version Upgrade • From Edition 2006 or 2007 to FMS-5613 Edition 2008 • From V6.0, V6.1, V6.2 or V6.3 to FMS-5613 Edition 2008 HARDNET-PB S7 V8.2 For 32/64-bit: Windows 7 Professional/Ultimate; for 64-bit: Windows 2008 Server R2 German/English • Single License for one installation PROFIBUS FC Standard Cable GP 6GK1713-5CB08-2AA0 S7-5613 Edition 2008 6GK1713-5CB71-3AA0 PROFIBUS bus terminal 12M Software Update Service 6GK1713-5CB00-3AL0 Bus terminal for connection of PROFIBUS stations up to 12 Mbit/s with plug-in cable 1.5 m long Upgrade • From Edition 2006 or 2007 to S7-5613 Edition 2008 or HARDNET-PB S7 V8.1 • From V6.0, V6.1, V6.2 or V6.3 to S7-5613 Edition 2008 or HARDNET-PB S7 V8.1 PROFIBUS FastConnect bus connector RS485 Plug 180 PROFIBUS FastConnect Stripping Tool 6GK1713-5CB00-3AE0 6GK1713-5CB00-3AE1 6GK1713-5FB71-3AA0 ■ More information You can find the HARDNET-PB DP Development Kit on the Internet. You will find more information on the Internet at: http://www.siemens.com/simatic-net/dk5613 The CP 5613 A2 module can also be used under the LINUX and UNIX operating systems. Information on the available LINUX distributors and UNIX operating systems can be found at: www.siemens.com/simatic-net/ik-info 5/212 6GK1713-5FB00-3AE0 6GK1713-5FB00-3AE1 6XV1830-0EH10 6GK1500-0FC10 With 180° cable outlet, insulation displacement FMS-5613 Edition 2008 Software for FMS protocol, including PG/OP communication, FDL, FMS-OPC server and NCM PC; runtime software, software and electronic manual on USB flash drive, Class A for 32-bit Windows XP Professional SP2/3, Windows 2003 Server R2, SP2, Windows Vista Business/Ultimate SP1; Windows 2008 Server; for CP 5613, CP 5613 A2, CP 5613 FO, CP 5614, CP 5614 A2; German/English • Single License for one installation 6GK1713-5FB00-3AL0 Standard type with special design for quick assembly, 2-core, shielded, sold in meters; delivery unit max. 1000 m, minimum order 20 m For 32-bit Windows XP Professional SP2/3; Windows 2003 Server R2, SP2; Windows Vista Business/Ultimate SP1; Windows 2008 Server; English/German • Single License for one installation For 1 year with automatic extension; requirement: current software version 5 Order No. HARDNET-PB S7 Siemens ST 80 / ST PC · 2013 Preset stripping tool for fast stripping of PROFIBUS FastConnect bus cables 6GK1500-0AA10 6GK1905-6AA00 © Siemens AG 2013 PC-based Automation Communication — PROFIBUS CP 5614 A2 ■ Overview ■ Ordering data Order No. CP 5614 A2 communications processor 6GK1561-4AA01 PCI card (32-bit; 3.3 V/5 V) master and slave connection to PROFIBUS incl. DP-Base software with NCM PC; DP-RAM interface for DP master, incl. PG and FDL protocols; single license for one installation, runtime software, software and electronic manual on CD-ROM, Class A, for operating system support see SIMATIC NET software; German/English Software Upgrade 6GK1561-3AA01-3AE0 For CP 5614 A2 and CP 5624 to Edition 2008 or V8.1 HARDNET-PB DP Development Kit '36 )06 23& 3*23 66 *B,.B;;B '30 • PCI card (universal keyed 5 V/3.3 V) with own microprocessor for connection of PCs and SIMATIC PG/PC to PROFIBUS at up to 12 Mbit/s • Communication services: - PROFIBUS DP master and slave interface according to IEC 61158/61784 on one PCI card - PG/OP communication with STEP 5 and STEP 7 - S7 communication with HARDNET-PB S7 software package - Open communication (SEND/RECEIVE) based on the FDL interface - PROFIBUS FMS according to IEC 61158/61784 with FMS-5613 software package • Comprehensive diagnostics possibilities for installation, commissioning and operation of the module • High performance over direct dual-port RAM access • Event and filter mechanisms to reduce the loading on the host CPU • Multiprotocol operation and parallel operation of up to four CPs • Implementation of Motion Control applications is possible because a constant bus cycle time is supported • The appropriate OPC servers and configuration tools are included in the scope of supply of the respective communications software. See http://www.siemens.com/ simatic-net/dk5613 HARDNET-PB DP Development Kit software for CP 5613/CP 5614/ CP 5613 A2/CP 5614 A2/ CP 5613 FO for integration into other operating system environments on systems with a PCI slot HARDNET-PB DP Software for DP, incl. PG and FDL protocol, OPC server and NCM PC; runtime software, software and electronic manual on CD-ROM, license key on USB flash drive, Class A, for CP 5603, CP 5613 A2, CP 5623, CP 5614, CP 5614 A2, CP 5624; HARDNET-PB DP V8.2 For 32/64-bit: Windows 7 Professional/Ultimate; for 64-bit: Windows 2008 Server R2 German/English • Single License for one installation 5 6GK1713-5DB08-2AA0 DP-5613 Edition 2008 For 32-bit Windows XP Professional SP2/3; Windows 2003 Server R2, SP2; Windows Vista Business/Ultimate SP1; Windows 2008 Server; English/German • Single License for one installation 6GK1713-5DB71-3AA0 Software Update Service 6GK1713-5DB00-3AL0 For 1 year with automatic extension; requirement: current software version Upgrade • From Edition 2006 or 2007 to DP-5613 Edition 2008 or HARDNET-PB DP V8.1 • From V6.0, V6.1, V6.2 or V6.3 to DP-5613 Edition 2008 or HARDNET-PB DP V8.1 6GK1713-5DB00-3AE0 6GK1713-5DB00-3AE1 Siemens ST 80 / ST PC · 2013 5/213 © Siemens AG 2013 PC-based Automation Communication — PROFIBUS CP 5614 A2 ■ Ordering data Order No. Software Update Service Software for S7 communication, incl. PG and FDL protocol, OPC server and NCM PC; runtime software, software and electronic manual on USB flash drive, Class A, for CP 5603, CP 5613 A2, CP 5623, CP 5614 A2, CP 5624; For 1 year with automatic extension; requirement: current software version Upgrade • From Edition 2006 or 2007 to FMS-5613 Edition 2008 • From V6.0, V6.1, V6.2 or V6.3 to FMS-5613 Edition 2008 HARDNET-PB S7 V8.2 For 32/64-bit: Windows 7 Professional/Ultimate; for 64-bit: Windows 2008 Server R2 German/English • Single License for one installation PROFIBUS FC Standard Cable GP 6GK1713-5CB08-2AA0 For 32-bit Windows XP Professional SP2/3; Windows 2003 Server R2, SP2; Windows Vista Business/Ultimate SP1; Windows 2008 Server; English/German • Single License for one installation Upgrade • From Edition 2006 or 2007 to S7-5613 Edition 2008 or HARDNET-PB S7 V8.1 • From V6.0, V6.1, V6.2 or V6.3 to S7-5613 Edition 2008 or HARDNET-PB S7 V8.1 PROFIBUS bus terminal 12M 6GK1713-5CB71-3AA0 Bus terminal for connection of PROFIBUS stations up to 12 Mbit/s with plug-in cable 1.5 m long 6GK1713-5CB00-3AL0 PROFIBUS FastConnect Stripping Tool 6GK1713-5CB00-3AE0 6GK1713-5CB00-3AE1 FMS-5613 Edition 2008 Software for FMS protocol, including PG/OP communication, FDL, FMS-OPC server and NCM PC; runtime software, software and electronic manual on USB flash drive, Class A for 32-bit Windows XP Professional SP2/3, Windows 2003 Server R2, SP2, Windows Vista Business/Ultimate SP1; Windows 2008 Server; for CP 5613, CP 5613 A2, CP 5613 FO, CP 5614, CP 5614 A2, German/English • Single License for one installation 6GK1713-5FB71-3AA0 ■ More information You can find the HARDNET-PB DP Development Kit on the Internet. http://www.siemens.com/simatic-net/dk5613 5/214 6GK1713-5FB00-3AE0 6GK1713-5FB00-3AE1 6XV1830-0EH10 6GK1500-0FC10 With 180° cable outlet, insulation displacement Software Update Service For 1 year with automatic extension; requirement: current software version 6GK1713-5FB00-3AL0 Standard type with special design for quick assembly, 2-core, shielded, sold in meters; delivery unit max. 1000 m, minimum order 20 m PROFIBUS FastConnect bus connector RS485 Plug 180 S7-5613 Edition 2008 5 Order No. HARDNET-PB S7 Siemens ST 80 / ST PC · 2013 Preset stripping tool for fast stripping of PROFIBUS FastConnect bus cables 6GK1500-0AA10 6GK1905-6AA00 © Siemens AG 2013 PC-based Automation Communication — PROFIBUS CP 5623 ■ Overview ■ Ordering data Order No. CP 5623 communications processor 6GK1562-3AA00 PCI Express x1 card (32 bit) for connection to PROFIBUS incl. DP-Base software with NCM PC; DP-RAM interface for DP master or DP slave, incl. PG and FDL protocols; single license for one installation, runtime software, software and electronic manual on CD-ROM, Class A, for operating system support see SIMATIC NET software; German/English Software Upgrade 6GK1561-3AA01-3AE0 For CP 5603, CP 5613 A2 and CP 5623 to Edition 2008 or V8.1 see http://www.siemens.com/ simatic-net/dk5613 HARDNET-PB DP Development Kit '36 )06 23& 3*23 66 *B,.B;;B '30 • PCI Express card (PCIe x1) with own microprocessor for connecting PCs and SIMATIC PG/PC to PROFIBUS at up to 12 Mbit/s • Communication services: - PROFIBUS DP master Class 1 and 2 or DP slave according to IEC 61158/61784 on a PCI card - PG/OP communication with STEP 5 and STEP 7 - S7 communication with HARDNET-PB S7 software package - Open communication (SEND/RECEIVE) based on the FDL interface - PROFIBUS FMS according to IEC 61158/61784 with FMS-5613 software package • Extensive diagnostics options for installation, commissioning and operation of the module • Event and filter mechanism for reducing the load on the host CPU • Multiprotocol operation and parallel operation of up to four CPs • The appropriate OPC servers and configuration tools are included in the scope of supply of the respective communication software HARDNET-PB DP Development Kit software for CP 5603, CP 5613, CP 5613 A2, CP 5623, CP 5613 FO, CP 5614, CP 5614 A2, CP 5624; for integration into other operating system environments on systems with a PCI or PCI Express slot HARDNET-PB DP Software for DP, incl. PG and FDL protocol, OPC server and NCM PC; runtime software, software and electronic manual on CD-ROM, license key on USB flash drive, Class A, for CP 5603, CP 5613 A2, CP 5623, CP 5614 A2, CP 5624; HARDNET-PB DP V8.2 For 32/64-bit: Windows 7 Professional/Ultimate; for 64-bit: Windows 2008 Server R2 German/English • Single License for one installation 5 6GK1713-5DB08-2AA0 DP-5613, Edition 2008 For 32-bit Windows XP Professional SP2/3; Windows 2003 Server R2, SP2; indows Vista Business/ Ultimate SP1; Windows 2008 Server; English/German • Single License for one installation 6GK1713-5DB71-3AA0 Software Update Service 6GK1713-5DB00-3AL0 For 1 year with automatic extension; requirement: current software version Upgrade • From Edition 2006 or 2007 to DP-5613 Edition 2008 or HARDNET-PB DP V8.1 • From V6.0, V6.1, V6.2 or V6.3 to DP-5613 Edition 2008 or HARDNET-PB DP V8.1 6GK1713-5DB00-3AE0 6GK1713-5DB00-3AE1 Siemens ST 80 / ST PC · 2013 5/215 © Siemens AG 2013 PC-based Automation Communication — PROFIBUS CP 5623 ■ Ordering data Order No. Software Update Service Software for S7 communication, incl. PG and FDL protocol, OPC server and NCM PC; runtime software, software and electronic manual on USB flash drive, Class A, for CP 5603, CP 5613 A2, CP 5623, CP 5614 A2, CP 5624; For 1 year with automatic extension; requirement: current software version Upgrade • From Edition 2006 or 2007 to FMS-5613 Edition 2008 • From V6.0, V6.1, V6.2 or V6.3 to FMS-5613 Edition 2008 HARDNET-PB S7 V8.2 For 32/64-bit: Windows 7 Professional/Ultimate; for 64-bit: Windows 2008 Server R2 German/English • Single License for one installation PROFIBUS FC Standard Cable GP 6GK1713-5CB08-2AA0 S7-5613 Edition 2008 6GK1713-5CB71-3AA0 PROFIBUS bus terminal 12M Software Update Service 6GK1713-5CB00-3AL0 Bus terminal for connection of PROFIBUS stations up to 12 Mbit/s with plug-in cable 1.5 m long Upgrade • From Edition 2006 or 2007 to S7-5613 Edition 2008 or HARDNET-PB S7 V8.1 • From V6.0, V6.1, V6.2 or V6.3 to S7-5613 Edition 2008 or HARDNET-PB S7 V8.1 PROFIBUS FastConnect bus connector RS485 Plug 180 PROFIBUS FastConnect Stripping Tool 6GK1713-5CB00-3AE0 6GK1713-5CB00-3AE1 6GK1713-5FB71-3AA0 ■ More information You can find the HARDNET-PB DP Development Kit on the Internet. You will find more information on the Internet at: http://www.siemens.com/simatic-net/dk5613 The CP 5623 module can also be used under LINUX and UNIX operating systems. Information on the available LINUX distributors and UNIX operating systems can be found at: www.siemens.com/simatic-net/ik-info 5/216 6GK1713-5FB00-3AE0 6GK1713-5FB00-3AE1 6XV1830-0EH10 6GK1500-0FC10 With 180° cable outlet, insulation displacement FMS-5613 Edition 2008 Software for FMS protocol incl. PG/OP communication; FDL, FMS-OPC server and NCM PC; runtime software, software and electronic manual on USB stick, Class A, for 32-bit Windows XP Professional SP2/3; Windows 2003 Server R2, SP2; Windows Vista Business/ Ultimate SP1; Windows 2008 Server; for CP 5603, CP 5613, CP 5613 A2, CP 5623, CP 5613 FO, CP 5614, CP 5614 A2, CP 5624; German/English • Single License for one installation 6GK1713-5FB00-3AL0 Standard type with special design for quick assembly, 2-core, shielded, sold in meters; delivery unit max. 1000 m, minimum order 20 m For 32-bit Windows XP Professional SP2/3; Windows 2003 Server R2, SP2; Windows Vista Business/ Ultimate SP1; Windows 2008 Server; English/German • Single License for one installation For 1 year with automatic extension; requirement: current software version 5 Order No. HARDNET-PB S7 Siemens ST 80 / ST PC · 2013 Preset stripping tool for fast stripping of PROFIBUS FastConnect bus cables 6GK1500-0AA10 6GK1905-6AA00 © Siemens AG 2013 PC-based Automation Communication — PROFIBUS CP 5624 ■ Overview ■ Ordering data Order No. CP 5624 A2 communications processor 6GK1562-4AA00 PCI Express x1 card (32 bit) for master and slave connection to PROFIBUS incl. DP-Base software with NCM PC; DP-RAM interface for DP master, incl. PG and FDL protocols; single license for one installation, runtime software, software and electronic manual on CD-ROM, Class A, for operating system support see SIMATIC NET software; German/English Software Upgrade 6GK1561-3AA01-3AE0 for CP 5614 A2 and CP 5624 to Edition 2008 or V8.1 HARDNET-PB DP Development Kit '36 )06 23& 3*23 66 *B,.B;;B '30 • PCI Express card (PCIe x1) with own microprocessor for connecting PCs and SIMATIC PG/PC to PROFIBUS at up to 12 Mbit/s • Two 9-pin sub-D sockets for parallel operation as DP master and DP slave • Communication services: - PROFIBUS DP master and slave interface according to IEC 61158/61784 on one PCI card - PG/OP communication with STEP 5 and STEP 7 - S7 communication with HARDNET-PB S7 software package - Open communication (SEND/RECEIVE) based on the FDL interface - PROFIBUS FMS according to IEC 61158/61784 with FMS-5613 software package • Extensive diagnostics options for installation, commissioning and operation of the module • Event and filter mechanism for reducing the load on the host CPU • Multiprotocol operation and parallel operation of up to four CPs • The appropriate OPC servers and configuration tools are included in the scope of supply of the respective communication software HARDNET-PB DP Development Kit software for CP 5603, CP 5613, CP 5613 A2, CP 5623, CP 5613 FO, CP 5614, CP 5614 A2, CP 5624; for integration into other operating system environments on systems with a PCI or PCI Express slot see http://www.siemens.com/ simatic-net/dk5613 HARDNET-PB DP Software for DP, incl. PG and FDL protocol, OPC server and NCM PC; runtime software, software and electronic manual on CD-ROM, license key on USB flash drive, Class A, for CP 5603, CP 5613 A2, CP 5623, CP 5614 A2, CP 5624; HARDNET-PB DP V8.2 For 32/64-bit: Windows 7 Professional/Ultimate; for 64-bit: Windows 2008 Server R2 German/English • Single License for one installation 5 6GK1713-5DB08-2AA0 DP-5613, Edition 2008 For 32-bit Windows XP Professional SP2/3; Windows 2003 Server R2, SP2; Windows Vista Business/Ultimate SP1; Windows 2008 Server; English/German • Single License for one installation 6GK1713-5DB71-3AA0 Software Update Service 6GK1713-5DB00-3AL0 For 1 year with automatic extension; requirement: current software version Upgrade • From Edition 2006 or 2007 to DP-5613 Edition 2008 or HARDNET-PB DP V8.1 • From V6.0, V6.1, V6.2 or V6.3 to DP-5613 Edition 2008 or HARDNET DP V8.1 6GK1713-5DB00-3AE0 6GK1713-5DB00-3AE1 Siemens ST 80 / ST PC · 2013 5/217 © Siemens AG 2013 PC-based Automation Communication — PROFIBUS CP 5624 ■ Ordering data Order No. FMS-5613 Edition 2008 Software for S7 communication, incl. PG and FDL protocol, OPC server and NCM PC; runtime software, software and electronic manual on USB flash drive, Class A, for CP 5603, CP 5613 A2, CP 5623, CP 5614 A2, CP 5624; Software for FMS protocol incl. PG/OP communication; FDL, FMS-OPC server and NCM PC; runtime software, software and electronic manual on USB flash drive, Class A, for 32-bit Windows XP Professional SP2/3; Windows 2003 Server R2, SP2; Windows Vista Business/Ultimate SP1; Windows 2008 Server; for CP 5603, CP 5613, CP 5613 A2, CP 5623, CP 5613 FO, CP 5614, CP 5614 A2, CP 5624; German/English • Single License for one installation 6GK1713-5FB71-3AA0 Software Update Service 6GK1713-5FB00-3AL0 HARDNET-PB S7 V8.2 For 32/64-bit: Windows 7 Professional/Ultimate; for 64-bit: Windows 2008 Server R2 German/English • Single License for one installation 6GK1713-5CB08-2AA0 S7-5613 Edition 2008 For 1 year with automatic extension; requirement: current software version For 32-bit Windows XP Professional SP2/3; Windows 2003 Server R2, SP2; Windows Vista Business/Ultimate SP1; Windows 2008 Server; English/German • Single License for one installation 6GK1713-5CB71-3AA0 Software Update Service 6GK1713-5CB00-3AL0 For 1 year with automatic extension; requirement: current software version Upgrade • From Edition 2006 or 2007 to S7-5613 Edition 2008 or HARDNET-PB S7 V8.1 • From V6.0, V6.1, V6.2 or V6.3 to S7-5613 Edition 2008 or HARDNET-PB S7 V8.1 5 Order No. HARDNET-PB S7 PROFIBUS FastConnect bus connector RS 485 Plug 180 6GK1713-5FB00-3AE0 6GK1713-5FB00-3AE1 6GK1500-0FC10 with 180° cable outlet PROFIBUS bus terminal 12M 6GK1713-5CB00-3AE0 6GK1713-5CB00-3AE1 ■ More information You can find the HARDNET-PB DP Development Kit on the Internet. You can find more information on the Internet at: http://www.siemens.com/simatic-net/dk5613 5/218 Upgrade • From Edition 2006 or 2007 to FMS-5613 Edition 2008 • From V6.0, V6.1, V6.2 or V6.3 to FMS-5613 Edition 2008 Siemens ST 80 / ST PC · 2013 Bus terminal for connection of PROFIBUS stations for up to 12 Mbit/s with plug-in cable 6GK1500-0AA10 © Siemens AG 2013 PC-based Automation Communication — PROFIBUS CP 5512 ■ Overview ■ Ordering data Order No. CP 5512 communications processor 6GK1551-2AA00 PC-Card (CardBus, 32-bit) for connection of a programming device or notebook to PROFIBUS or MPI, under 32 bit in connection with PROFIBUS SOFTNET software or STEP 7; German/English SOFTNET-PB S7 Software for S7 communication, incl. FDL protocol with OPC server and NCM PC, runtime software, software and electronic manual on CD-ROM, license key on USB flash drive, Class A; for CP 5512, CP 5611, CP 5611 A2, CP 5612 (Win 7 and higher), CP 5621, CP 5622 (Win 7 and higher), CP 5711; '36 )06 23& 3*23 SOFTNET-PB S7 V8.2 66 *B,.B;;B '30 • PC Card Type II (CardBus 32 bit) to connect PG/PC and notebooks with PC card slot (CardBus 32 bit) to PROFIBUS and to the MPI of the SIMATIC S7 • Communication services: - PROFIBUS DP Master Class 1 incl. acyclic DP expansions with SOFTNET-PB DP software package - PROFIBUS DP Master Class 2 incl. acyclic DP expansions with SOFTNET-PB DP software package - PROFIBUS DP slave with SOFTNET-PB DP Slave software package - PG/OP communication with STEP 5 or STEP 7 - S7 communication with SOFTNET-PB S7 software package - Open communication (SEND/RECEIVE on basis of the FDL interface) with SOFTNET-PB DP or SOFTNET-PB S7 software package • Can be used with: - STEP 7 and NCM PC; (ProTool, Micro/Win, ProTool/Pro, SIMATIC PDM for PG/OP communication) - SOFTNET-PB S7 (for S7 communication) - SOFTNET-PB DP, SOFTNET-PB DP slave (for DP) • The appropriate OPC servers are included in the scope of supply of the respective communication software for 32 Bit Windows 7 Professional/ Ultimate; English/German • Single License for one installation 6GK1704-5CW08-2AA0 SOFTNET-S7 Edition 2008 for 32 Bit Windows XP Professional SP2/3; Windows 2003 Server R2, SP2; Windows Vista Business/ Ultimate SP1; Windows 2008 Server; English/German • Single License for one installation 6GK1704-5CW71-3AA0 Software Update Service 6GK1704-5CW00-3AL0 For 1 year with automatic extension; requirement: current software version Upgrade • From Edition 2006 to SOFTNET-S7 Edition 2008 or V8.1 • From V6.0, V6.1, V6.2 or V6.3 to SOFTNET-S7 Edition 2008 or V8.1 6GK1704-5CW00-3AE0 5 6GK1704-5CW00-3AE1 Siemens ST 80 / ST PC · 2013 5/219 © Siemens AG 2013 PC-based Automation Communication — PROFIBUS CP 5512 ■ Ordering data Order No. Order No. SOFTNET-PB DP SOFTNET-PB DP slave Software for DP protocol (master class 1 and 2), incl. FDL protocol with OPC server and NCM PC, runtime software, software and electronic manual on CD-ROM, license key on USB flash drive; for CP 5512, CP 5611, CP 5611 A2, CP 5612 (Win 7 and higher), CP 5621, CP 5622 (Win 7 and higher), CP 5711; Software for DP slave, with DP OPC server and NCM PC, single license for one installation, runtime software, software and electronic manual on CD-ROM, license key on USB flash drive, Class A; for CP 5512, CP 5611, CP 5611 A2, CP 5612 (Win 7 and higher), CP 5621, CP 5622 (Win 7 and higher), CP 5711; SOFTNET-PB DP Slave V8.2 SOFTNET-PB DP V8.2 for 32 Bit Windows 7 Professional/ Ultimate; English/German • Single License for one installation 6GK1704-5DW08-2AA0 SOFTNET-DP Edition 2008 (V7.1) 6GK1704-5SW08-2AA0 SOFTNET-DP Slave Edition 2008 (V7.1) for Windows XP Professional SP2/3; Windows 2003 Server R2, SP2; Windows Vista Business/Ultimate SP1; Windows 2008 Server; English/German • Single License for one installation 6GK1704-5DW71-3AA0 Software Update Service 6GK1704-5DW00-3AL0 For 1 year with automatic extension; requirement: current software version Upgrade • From Edition 2006 to SOFTNET-DP Edition 2008 or V8.1 • From V6.0, V6.1, V6.2 or V6.3 to SOFTNET-DP Edition 2008 or V8.1 for 32/64-bit: Windows 7 Professional/Ultimate; for 64-bit: Windows 2008 Server R2 German/English • Single License for one installation 6GK1704-5DW00-3AE0 6GK1704-5DW00-3AE1 5 for 32 Bit Windows XP Professional SP2/3; Windows 2003 Server R2, SP2; Windows Vista Business/ Ultimate SP1; Windows 2008 Server; English/German • Single License for one installation 6GK1704-5SW71-3AA0 Software Update Service 6GK1704-5SW00-3AL0 For 1 year with automatic extension; requirement: current software version Upgrade • From Edition 2006 to SOFTNET-DP Slave Edition 2008 or V8.1 • From V6.0, V6.1, V6.2 or V6.3 to SOFTNET-DP Slave Edition 2008 or V8.1 PROFIBUS FastConnect bus connector RS 485 Plug 180 6GK1704-5SW00-3AE0 6GK1704-5SW00-3AE1 6GK1500-0FC10 With 180° cable outlet PROFIBUS adapter for CP 5512 5/220 Siemens ST 80 / ST PC · 2013 C79459-A1890-A10 © Siemens AG 2013 PC-based Automation Communication — PROFIBUS CP 5612 ■ Overview ■ Ordering data Order No. CP 5612 communications processor • PCI card (32-bit) for connection of a programming device or PC to PROFIBUS • PCI card (32-bit) CP 5612 and MPI cable, 5 m 6GK1561-2AA00 6GK1561-2AM00 SOFTNET-PB S7 Software for S7 communication, incl. FDL protocol with OPC server and NCM PC, runtime software, software and electronic manual on CD-ROM, license key on USB flash drive, Class A; for CP 5512, CP 5611, CP 5611 A2, CP 5612 (Win 7 and higher), CP 5621, CP 5622 (Win 7 and higher), CP 5711; SOFTNET-PB S7 V8.2 '36 )06 23& 3*23 66 *B,.B;;B '30 • PCI card (universal-keyed 5 V/3.3 V) for connecting PCs and SIMATIC PG/PC to PROFIBUS at up to 12 Mbit/s and to the MPI interface of SIMATIC S7 • Communication services: - PROFIBUS DP Master Class 1 incl. acyclic DP expansions with SOFTNET-PB DP software package - PROFIBUS DP Master Class 2 incl. acyclic DP expansions with SOFTNET-PB DP software package - PROFIBUS DP slave with SOFTNET-PB DP Slave software package - PG/OP communication with STEP 7 - S7 communication with SOFTNET-PB S7 software package - Open communication (SEND/RECEIVE on basis of the FDL interface) with SOFTNET-PB DP or SOFTNET-PB S7 software package • Can be used with: - STEP 7, STEP 7-Micro/Win, SIMATIC PDM (for PG/OP communication) - SOFTNET-PB S7 (for S7 communication) - SOFTNET-PB DP, SOFTNET-PB DP slave (for DP) • The appropriate OPC servers and configuration tools are included in the scope of supply of the respective communications software. For 32/64-bit: Windows 7 Professional/Ultimate; for 64-bit: Windows 2008 Server R2 German/English • Single License for one installation 6GK1704-5CW08-2AA0 Software Update Service 6GK1704-5CW00-3AL0 For 1 year with automatic extension; requirement: current software version Upgrade • From Edition 2006 to SOFTNET-S7 Edition 2008 or V8.1 • From V6.0, V6.1, V6.2 or V6.3 to SOFTNET-S7 Edition 2008 or V8.1 6GK1704-5CW00-3AE0 6GK1704-5CW00-3AE1 SOFTNET-PB DP Software for DP protocol (master class 1 and 2), incl. FDL protocol with OPC server and NCM PC, runtime software, software and electronic manual on CD-ROM, license key on USB flash drive; for CP 5611 A2, CP 5612 (Win 7 and higher), CP 5621, CP 5622 (Win 7 and higher), CP 5711; 5 SOFTNET-PB DP V8.2 For 32/64-bit: Windows 7 Professional/Ultimate; for 64-bit: Windows 2008 Server R2 German/English • Single License for one installation 6GK1704-5DW08-2AA0 Software Update Service 6GK1704-5DW00-3AL0 For 1 year with automatic extension; requirement: current software version Upgrade • From Edition 2006 to SOFTNET-DP Edition 2008 or V8.1 • From V6.0, V6.1, V6.2 or V6.3 to SOFTNET-DP Edition 2008 or V8.1 6GK1704-5DW00-3AE0 6GK1704-5DW00-3AE1 Siemens ST 80 / ST PC · 2013 5/221 © Siemens AG 2013 PC-based Automation Communication — PROFIBUS CP 5612 ■ Ordering data Order No. Order No. SOFTNET-PB DP slave Software Update Service Software for DP slave, with DP OPC server and NCM PC, single license for one installation, runtime software, software and electronic manual on CD-ROM, license key on USB flash drive, Class A; for CP 5611 A2, CP 5612 (Win 7 and higher), CP 5621, CP 5622 (Win 7 and higher), CP 5711; For 1 year with automatic extension; requirement: current software version Upgrade • From Edition 2006 to SOFTNET-DP Slave Edition 2008 or V8.1 • From V6.0, V6.1, V6.2 or V6.3 to SOFTNET-DP Slave Edition 2008 or V8.1 SOFTNET-PB DP Slave V8.2 for 32/64-bit: Windows 7 Professional/Ultimate; for 64-bit: Windows 2008 Server R2 German/English • Single License for one installation PROFIBUS FastConnect bus connector RS 485 Plug 180 6GK1704-5SW00-3AE0 6GK1704-5SW00-3AE1 6GK1500-0FC10 With 180° cable outlet 6GK1704-5SW08-2AA0 PROFIBUS bus terminal 12M Bus terminal for connection of PROFIBUS stations for up to 12 Mbit/s with plug-in cable 5 5/222 6GK1704-5SW00-3AL0 Siemens ST 80 / ST PC · 2013 6GK1500-0AA10 © Siemens AG 2013 PC-based Automation Communication — PROFIBUS CP 5622 ■ Overview ■ Ordering data Order No. CP 5622 communications processor • PCI Express x1 card (32-bit) for connection of a PG or PC to PROFIBUS • PCI Express x1 card (32-bit) CP 5622 and MPI cable, 5 m 6GK1562-2AA00 6GK1562-2AM00 SOFTNET-PB S7 Software for S7 communication, incl. FDL protocol with OPC server and NCM PC, runtime software, software and electronic manual on CD-ROM, license key on USB flash drive, Class A; for CP 5512, CP 5611, CP 5611 A2, CP 5612 (Win 7 and higher), CP 5621, CP 5622 (Win 7 and higher), CP 5711; SOFTNET-PB S7 V8.2 '36 )06 23& 3*23 66 *B,.B;;B '30 • PCI Express card (PCIe x1) for connection of PCs and SIMATIC PG/PC to PROFIBUS at up to 12 Mbit/s and to the MPI of the SIMATIC S7 • Communication services: - PROFIBUS DP Master Class 1 incl. acyclic DP expansions with SOFTNET-PB DP software package - PROFIBUS DP Master Class 2 incl. acyclic DP expansions with SOFTNET-PB DP software package - PROFIBUS DP slave with SOFTNET-PB DP Slave software package - PG/OP communication with STEP 7 - S7 communication with SOFTNET-PB S7 software package - Open communication (SEND/RECEIVE on basis of the FDL interface) with SOFTNET-PB DP or SOFTNET-PB S7 software package • Can be used with: - STEP 7, STEP 7-Micro/Win, SIMATIC PDM (for PG/OP communication) - SOFTNET-PB S7 (for S7 communication) - SOFTNET-PB DP, SOFTNET-PB DP slave (for DP) • The appropriate OPC servers and configuration tools are included in the scope of supply of the respective communications software. For 32/64-bit: Windows 7 Professional/Ultimate; for 64-bit: Windows 2008 Server R2 German/English • Single License for one installation 6GK1704-5CW08-2AA0 Software Update Service 6GK1704-5CW00-3AL0 For 1 year with automatic extension; requirement: current software version Upgrade • From Edition 2006 to SOFTNET-S7 Edition 2008 or V8.1 • From V6.0, V6.1, V6.2 or V6.3 to SOFTNET-S7 Edition 2008 or V8.1 6GK1704-5CW00-3AE0 6GK1704-5CW00-3AE1 SOFTNET-PB DP Software for DP protocol (master class 1 and 2), incl. FDL protocol with OPC server and NCM PC, runtime software, software and electronic manual on CD-ROM, license key on USB flash drive; for CP 5611 A2, CP 5612 (Win 7 and higher), CP 5621, CP 5622 (Win 7 and higher), CP 5711; 5 SOFTNET-PB DP V8.2 For 32/64-bit: Windows 7 Professional/Ultimate; for 64-bit: Windows 2008 Server R2 German/English • Single License for one installation 6GK1704-5DW08-2AA0 Software Update Service 6GK1704-5DW00-3AL0 For 1 year with automatic extension; requirement: current software version Upgrade • From Edition 2006 to SOFTNET-DP Edition 2008 or V8.1 • From V6.0, V6.1, V6.2 or V6.3 to SOFTNET-DP Edition 2008 or V8.1 6GK1704-5DW00-3AE0 6GK1704-5DW00-3AE1 Siemens ST 80 / ST PC · 2013 5/223 © Siemens AG 2013 PC-based Automation Communication — PROFIBUS CP 5622 ■ Ordering data Order No. SOFTNET-PB DP slave Software for DP slave, with DP OPC server and NCM PC, single license for one installation, runtime software, software and electronic manual on CD-ROM, license key on USB flash drive, Class A; for CP 5611 A2, CP 5612 (Win 7 and higher), CP 5621, CP 5622 (Win 7 and higher), CP 5711; PROFIBUS FastConnect bus connector RS 485 Plug 180 6GK1704-5SW00-3AE0 6GK1704-5SW00-3AE1 6GK1500-0FC10 With 180° cable outlet SOFTNET-PB DP Slave V8.2 PROFIBUS bus terminal 12M For 32/64-bit: Windows 7 Professional/Ultimate; for 64-bit: Windows 2008 Server R2 German/English • Single License for one installation 6GK1704-5SW08-2AA0 Software Update Service 6GK1704-5SW00-3AL0 Bus terminal for connection of PROFIBUS stations for up to 12 Mbit/s with plug-in cable For 1 year with automatic extension; requirement: current software version 5 5/224 Order No. Upgrade • From Edition 2006 to SOFTNET-DP Slave Edition 2008 or V8.1 • From V6.0, V6.1, V6.2 or V6.3 to SOFTNET-DP Slave Edition 2008 or V8.1 Siemens ST 80 / ST PC · 2013 6GK1500-0AA10 © Siemens AG 2013 PC-based Automation Communication — PROFIBUS CP 5711 ■ Overview ■ Ordering data Order No. CP 5711 communications processor for connection of a programming device or notebook to PROFIBUS or MPI, under 32 bit in connection with PROFIBUS SOFTNET software or STEP 7; German/English • USB V2.0 adapter • USB V2.0 adapter CP 5711 and MPI cable, 5 m Mounting rail support for CP 5711 6GK1571-1AA00 6GK1571-1AM00 6GK1571-1AA00-0AH0 Compartment for CP 5711 enclosure; fastened mechanically to 35 mm DIN rail SOFTNET-PB S7 '36 )06 23& 3*23 66 *B,.B;;B '30 Software for S7 communication, incl. FDL protocol with OPC server and NCM PC, runtime software, software and electronic manual on CD-ROM, license key on USB flash drive, Class A; for CP 5611 A2, CP 5612 (Win 7 and higher), CP 5621, CP 5622 (Win 7 and higher), CP 5711; SOFTNET-PB S7 V8.2 • USB adapter for the connection of PCs and SIMATIC PG/PC to PROFIBUS DP or MPI via USB 2.0 • Operation in extended temperature range of -20 °C to +60 °C • Active PROFIBUS termination to supply the PROFIBUS network as end station of a segment • Robust USB connection due to mechanical locking of the USB connector to the CP 5711 enclosure • Communication services: - PROFIBUS DP master Class 1 and 2 according to IEC 61158/61784 with SOFTNET-PB DP software package - PROFIBUS DP slave with SOFTNET-PB DP Slave software package - PG/OP communication with STEP 5 or STEP 7 software package - S7 communication with SOFTNET-PB S7 software package - Open communication (SEND/RECEIVE on basis of the FDL interface) with SOFTNET-PB DP or SOFTNET-PB S7 software package • PROFIBUS connection with up to 12 Mbit/s • Can be used with: - STEP 7, STEP 7 Micro/WIN, WinCC/WinCC flexible, NCM PC, SIMATIC PDM (for PG/OP communication) - SOFTNET-PB S7 (for S7 communication) - SOFTNET-PB DP, SOFTNET-PB DP slave (for DP) • The appropriate OPC servers and configuration tools are included in the scope of supply of the respective communication software For 32/64-bit: Windows 7 Professional/Ultimate; for 64-bit: Windows 2008 Server R2 German/English • Single License for one installation 6GK1704-5CW08-2AA0 SOFTNET-S7 Edition 2008 (V7.1) For 32-bit Windows XP Professional SP2/3; Windows 2003 Server R2, SP2; Windows Vista Business/ Ultimate SP1; Windows 2008 Server; English/German • Single License for one installation 6GK1704-5CW71-3AA0 Software Update Service 6GK1704-5CW00-3AL0 5 For 1 year with automatic extension; requirement: current software version Upgrade • From Edition 2006 to SOFTNET-S7 Edition 2008 or V8.1 • From V6.0, V6.1, V6.2 or V6.3 to SOFTNET-S7 Edition 2008 or V8.1 6GK1704-5CW00-3AE0 6GK1704-5CW00-3AE1 Siemens ST 80 / ST PC · 2013 5/225 © Siemens AG 2013 PC-based Automation Communication — PROFIBUS CP 5711 ■ Ordering data Order No. Order No. SOFTNET-PB DP SOFTNET-PB DP slave Software for DP protocol (master class 1 and 2), incl. FDL protocol with OPC server and NCM PC, runtime software, software and electronic manual on CD-ROM, license key on USB flash drive; for CP 5611 A2, CP 5612 (Win 7 and higher), CP 5621, CP 5622 (Win 7 and higher), CP 5711; Software for DP slave, with DP OPC server and NCM PC, single license for one installation, runtime software, software and electronic manual on CD-ROM, license key on USB flash drive, Class A; for CP 5611 A2, CP 5612 (Win 7 and higher), CP 5621, CP 5622 (Win 7 and higher), CP 5711; SOFTNET-PB DP Slave V8.2 SOFTNET-PB DP V8.2 For 32/64-bit: Windows 7 Professional/Ultimate; for 64-bit: Windows 2008 Server R2 German/English • Single License for one installation For 32/64-bit: Windows 7 Professional/Ultimate; for 64-bit: Windows 2008 Server R2 German/English • Single License for one installation 6GK1704-5DW08-2AA0 SOFTNET-DP Edition 2008 (V7.1) For Windows XP Professional SP2/3; Windows 2003 Server R2, SP2; Windows Vista Business/Ultimate SP1; Windows 2008 Server; English/German • Single License for one installation 6GK1704-5DW71-3AA0 Software Update Service 6GK1704-5DW00-3AL0 For 1 year with automatic extension; requirement: current software version Upgrade • From Edition 2006 to SOFTNET-DP Edition 2008 or V8.1 • From V6.0, V6.1, V6.2 or V6.3 to SOFTNET-DP Edition 2008 or V8.1 For 32-bit Windows XP Professional SP2/3; Windows 2003 Server R2, SP2; Windows Vista Business/ Ultimate SP1; Windows 2008 Server; English/German • Single License for one installation 6GK1704-5SW71-3AA0 Software Update Service 6GK1704-5SW00-3AL0 For 1 year with automatic extension; requirement: current software version 6GK1704-5DW00-3AE0 6GK1704-5DW00-3AE1 5 Upgrade • From Edition 2006 to SOFTNET-DP Slave Edition 2008 or V8.1 • From V6.0, V6.1, V6.2 or V6.3 to SOFTNET-DP Slave Edition 2008 or V8.1 PROFIBUS FastConnect bus connector RS485 Plug 180 With 180° cable outlet 5/226 6GK1704-5SW08-2AA0 SOFTNET-DP Slave Edition 2008 (V7.1) Siemens ST 80 / ST PC · 2013 6GK1704-5SW00-3AE0 6GK1704-5SW00-3AE1 6GK1500-0FC10 © Siemens AG 2013 PC-based Automation Communication — PROFIBUS SOFTNET for PROFIBUS ■ Overview ■ Ordering data Order No. SOFTNET-PB S7 Software for S7 communication, incl. FDL protocol with OPC server and NCM PC, runtime software, software and electronic manual on CD-ROM, license key on USB flash drive, Class A; for CP 5611 A2, CP 5612 (Win 7 and higher), CP 5621, CP 5622 (Win 7 and higher), CP 5711; PC/IPC with CP 5612/ CP 5622/CP 5711 and SOFTNET for PROFIBUS PROFIBUS SOFTNET-PB S7 V8.2 For 32/64-bit: Windows 7 Professional/Ultimate; for 64-bit: Windows 2008 Server R2 German/English • Single License for one installation S7-1200 with CM 1243-5 '36 )06 23& 3*23 66 *B,.B;;B '30 S7-300 with CP 342-5 S7-400 with or CP 343-5 CP 443-5 G_IK10_XX_50039 S5-115U to S5-155U with CP 5431 FMS/DP 6GK1704-5CW08-2AA0 SOFTNET-S7 Edition 2008 (V7.1) • Software for connecting PCs/programming devices and notebooks to programmable controllers • Communication services: - PROFIBUS DP master Class 1 and 2 with acyclic expansions - PROFIBUS DP slave - PG/OP communication - S7 communication - Open communication (SEND/RECEIVE) based on the FDL interface • The corresponding OPC servers are included in the scope of supply of the respective communication software • Can be used with: - CP 5512 (PC card, CardBus 32-bit) - CP 5611 A2 and CP 5612 (PCI, 32-bit) - CP 5612 (PCI, 32-bit) - CP 5621 and CP 5622 (PCIe x1) - CP 5622 (PCIe x1) - CP 5711 (USB V2.0) - Integrated PROFIBUS interfaces of SIMATIC PGs/PCs For 32-bit Windows XP Professional SP2/3; Windows 2003 Server R2, SP2; Windows Vista Business/ Ultimate SP1; Windows 2008 Server; English/German • Single License for one installation 6GK1704-5CW71-3AA0 Software Update Service 6GK1704-5CW00-3AL0 For 1 year with automatic extension; requirement: current software version Upgrade • From Edition 2006 to SOFTNET-S7 Edition 2008 or V8.1 • From V6.0, V6.1, V6.2 or V6.3 to SOFTNET-S7 Edition 2008 or V8.1 6GK1704-5CW00-3AE0 6GK1704-5CW00-3AE1 5 Siemens ST 80 / ST PC · 2013 5/227 © Siemens AG 2013 PC-based Automation Communication — PROFIBUS SOFTNET for PROFIBUS ■ Ordering data Order No. Order No. SOFTNET-PB DP SOFTNET-PB DP slave Software for DP protocol (master class 1 and 2), incl. FDL protocol with OPC server and NCM PC, runtime software, software and electronic manual on CD-ROM, license key on USB flash drive; for CP 5611 A2, CP 5612 (Win 7 and higher), CP 5621, CP 5622 (Win 7 and higher), CP 5711; Software for DP slave, with DP OPC server and NCM PC, single license for one installation, runtime software, software and electronic manual on CD-ROM, license key on USB flash drive, Class A; for CP 5611 A2, CP 5612 (Win 7 and higher), CP 5621, CP 5622 (Win 7 and higher), CP 5711; SOFTNET-PB DP V8.2 SOFTNET-PB DP Slave V8.2 For 32/64-bit: Windows 7 Professional/Ultimate; for 64-bit: Windows 2008 Server R2 German/English • Single License for one installation For 32/64-bit: Windows 7 Professional/Ultimate; for 64-bit: Windows 2008 Server R2 German/English • Single License for one installation 6GK1704-5DW08-2AA0 SOFTNET-DP Edition 2008 (V7.1) For Windows XP Professional SP2/3; Windows 2003 Server R2, SP2; Windows Vista Business/Ultimate SP1; Windows 2008 Server; English/German • Single License for one installation 6GK1704-5DW71-3AA0 Software Update Service 6GK1704-5DW00-3AL0 For 1 year with automatic extension; requirement: current software version Upgrade • From Edition 2006 to SOFTNET-DP Edition 2008 or V8.1 • From V6.0, V6.1, V6.2 or V6.3 to SOFTNET-DP Edition 2008 or V8.1 6GK1704-5DW00-3AE0 6GK1704-5DW00-3AE1 5 5/228 6GK1704-5SW08-2AA0 SOFTNET-DP Slave Edition 2008 (V7.1) Siemens ST 80 / ST PC · 2013 For 32-bit Windows XP Professional SP2/3; Windows 2003 Server R2, SP2; Windows Vista Business/ Ultimate SP1; Windows 2008 Server; English/German • Single License for one installation 6GK1704-5SW71-3AA0 Software Update Service 6GK1704-5SW00-3AL0 For 1 year with automatic extension; requirement: current software version Upgrade • From Edition 2006 to SOFTNET-DP Slave Edition 2008 or V8.1 • From V6.0, V6.1, V6.2 or V6.3 to SOFTNET-DP Slave Edition 2008 or V8.1 6GK1704-5SW00-3AE0 6GK1704-5SW00-3AE1 © Siemens AG 2013 PC-based Automation Communication — PROFIBUS OPC server for PROFIBUS ■ Overview PC/Windows PC SIMATIC NET OPC-Scout WinCC OPC-Client Microsoft Office OPC-Client OPC XML Webclient OPC UA COM/DCOM DP OPC server FMS OPC server DP protocol FMS protocol S7 OPC server S7 communication Internet Intranet S/R OPC server Open communication (SEND/RECEIVE) PN IO OPC server PROFINET SNMP OPC server OPC XML DA as Web service SNMP PROFINET Industrial Ethernet S7-1200 SIMATIC S7-1200 PC S7-400 S7-300 ET 200pro SIMATIC S5 (SEND/RECEIVE only) 5 PC PROFIBUS G_IK10_XX 50700 SIMATIC S5 System integration with OPC server • Standardized, open multi-vendor interface • Interfacing of OPC-capable Windows applications to DP, FMS, S7 communication and open communication (SEND/RECEIVE) based on the FDL interface • OPC Scout with browser functionality as an OPC client and OCX-Data-Control/.NET Data Control for simple OPC client creation • The relevant OPC servers are supplied with each communication software package Siemens ST 80 / ST PC · 2013 5/229 © Siemens AG 2013 PC-based Automation Communication — PROFIBUS S7 OPC Redundancy for PROFIBUS ■ Overview ■ Ordering data OPC (Openness, Productivity & Collaboration) is a standardized, open, and vendor-independent interface that is widely used in automation. OPC UA (Unified Architecture) is the result of consistent further development of this standard, offering additional functions such as security or redundancy. S7 OPC Redundancy is a software product compliant with the OPC UA standard that enables the redundant configuration of OPC UA servers to SIMATIC S7. The availability of automation data to operator control and monitoring systems is guaranteed thanks to the redundant use of OPC UA servers. This requires neither additional cabling for synchronizing the redundant OPC UA servers, nor additional programming overhead in the PC. The OPC UA servers are synchronized via high-performance Industrial Ethernet network access points at 10/100 and 1000 Mpbs. S7 OPC Redundancy represents an integrated customer solution for all SIMATIC NET S7 SOFTNET and HARDNET software products in the automation world. 5 5/230 Siemens ST 80 / ST PC · 2013 Order No. S7 OPC Redundancy Software for redundant OPC servers, Runtime software, software and electronic manual on CD-ROM, license key on USB stick, Class A S7 OPC Redundancy V8.2 for PROFIBUS For 64-bit Windows 2008 server R2; English/German • Single License for one installation 6GK1706-5CW08-2AA0 Software Update Service 6GK1706-5CW00-3AL0 For 1 year with automatic extension; requirement: current software version 6 © Siemens AG 2013 Customized Automation 6/2 6/2 Customized Automation Introduction 6/4 6/4 Customized adaptations Introduction 6/6 6/7 Customized hardware Design products 6/10 6/11 6/13 6/14 OEM products Flexible front design concept for HMI products MP 277 8" Touch control console SIMATIC HMI Net Panel 6/17 6/18 Turnkey products HMI operator stations 6/20 6/21 6/22 6/24 Customized software Remote Operate Software SIMATIC KNX/EIB2S7 S7 OpenModbusTCP 6/26 Examples of sector products 6/27 6/28 6/29 Renewable energy Solar systems Wind farms 6/30 6/30 6/32 6/33 Automotive industry HMI operator stations Front panel 15" with motion keys at side Mobile Panel 277 10" Remote Operate 6/36 6/36 General machine construction Front panel 15" Touch and Key for Panel PCs, resistant to honing oil Flat Panels, 10.4" for Panel PC 6/38 6/39 6/44 6/46 6/48 Food and beverages industry/ pharmaceuticals Panels and Panel PCs with stainless steel front HMI Panels as rear-mounted devices Flat Panels with stainless steel front HMI stainless steel operator stations 6/49 6/50 Oil & gas/chemicals/shipbuilding MP 377 15" Touch daylight readable 6/41 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Customized Automation Introduction Customized Automation ■ Overview OEM products Turnkey products G_ST80_XX_00557 Software products and customer-specific software images Standard products Design products Customized Automation - Hardware Customized Automation Customized Hardware Design products OEM products Turnkey products Customized Software Customized Service & Support SIMATIC standard products SIMATIC controller SIMATIC HMI Customized Automation - overview With Customized Automation, field-proven SIMATIC, SIMATIC PC and SIMATIC HMI standards are transferred to individual products and systems – tailored precisely to the customer's requirements. The portfolio covers the hardware and software range, as well as support and logistics. 6/2 Siemens ST 80 / ST PC · 2013 SIMATIC IPCs Customized Logistics G_ST80_XX_00441 6 © Siemens AG 2013 Customized Automation Introduction Customized Automation ■ Benefits Time savings • you can use comprehensive customization know-how and our long years of experience with the SIMATIC components • you do not have to build up any additional know-how, and you can concentrate completely on your own core competence Increase in profitability • you invest your money and resources selectively in your core competence • you implement reliable material requirements and logistics planning, tailored to your needs, thanks to our logistics services • you have maximum investment security thanks to maximum quality, long-term availability and continuity with SIMATIC, SIMATIC PC and SIMATIC HMI • you save unnecessary costs thanks to tailor-made solutions, and you benefit from the global service & support concepts with SIMATIC, SIMATIC IPC, and SIMATIC HMI Increase in competitive edge for the machine • you use SIMATIC products that correspond to the highest quality standards, offer optimal performance, and thus boost your productivity by minimizing standstill times • you receive customized products with Customized Automation that fit outstandingly well into the "Totally Integrated Automation" (TIA) concept • you stand out not only for exceptional technology but also for individual design of your machine, for example, by printing a logo on the front of the enclosure. Customized hardware: Customized products are modified SIMATIC HMI standard products. According to the necessary degree of modification of the hardware, these types of product are separately identified as: • Design products • OEM products • Turnkey products Customized software: In the case of customer-specific products, the software can also be individually installed. This includes the generation of operating systems and also the integration and installation of driver software and images – for complete, turnkey systems. Customized software products: • Remote Operate Software for implementation of multi-user systems with HMI IPC and clients on the basis of MP 377 and HMI IPC477 • SIMATIC KNX/EIB2S7 enables integration of actuators/sensors on a KNX/EIB bus of building automation systems into SIMATIC S7 • Open MODBUS for SIMATIC systems provides the capability of connecting systems from various manufacturers to SIMATIC automation systems Customized products from various industries SIMATIC HMI products are provided with additional features in order to facilitate optimum use in specific sectors of industry. Stainless steel front panels for the food, beverages and tobacco industry are one such example. With the exception of their front panels, the devices are identical to standard products in respect of function and technology. We can offer products for the following industries: • Renewable energy • Automotive industry - HMI for factory automation • General machine construction • Food and beverages industry/pharmaceuticals • Oil & gas/chemicals and shipbuilding Customized products for various industries are developed and produced in conjunction with a customized product agreement. ■ More information More information is available in the Internet at http://www.siemens.com/hmi-oem The customer-specific modifications are available in all performance classes, starting with Push Button Panels or Key Panels, Basic Panels, Comfort Panels up to Rack/Box/Panel PCs. 6 Siemens ST 80 / ST PC · 2013 6/3 © Siemens AG 2013 Customized Automation Introduction Customized adaptations ■ Application Customized Software Customized Logistics Customized Service & Support Our SIMATIC IPC Customization Centers convert the fieldproven SIMATIC IPCs into individualized products and systems for you – tailored precisely to your specific needs. Our portfolio ranges from individualized design, through software installation and special tests or certifications, right up to just-in-time delivery. This provides you with more time for your own projects while improving your profitability and thus your competitive advantage. Customized SIMATIC IPC precisely tailored to your requirements ■ Benefits You gain time because you ... • can benefit from our comprehensive customization expertise and many years of experience regarding industrial PCs. • do not have to create industrial computer-specific expertise and can therefore fully concentrate on your core competencies. 6 You increase profitability because you ... • invest your money and resources specifically in your core competencies. • implement a reliable inventory control and logistics planning as required thanks to our logistics services. • ensure maximum investment protection due to maximum quality, long-term availability and continuity with SIMATIC IPC. • avoid unnecessary costs due to custom-tailored solutions. • benefit from worldwide Service & Support concepts with SIMATIC IPC. You increase your competitive edge because you ... • use industrial PCs that conform to the highest quality standards, offer optimum performance, and thus increase productivity by minimizing downtimes. • use customer-specific SIMATIC IPCs that are optimally integrated in the Totally Integrated Automation (TIA) concept. • not only stand out due to extraordinary technology, but also due to the customized design of your machine, e.g. by printing a logo on the device front of the industrial PC. 6/4 Siemens ST 80 / ST PC · 2013 Driver development Image generation Requirements analysis, concept development, solution determination Long-term availability Demand-oriented manufacturing Individual labeling Adaptable packaging and delivery Requirements analysis, concept development, solution determination Customized project monitoring Individual repair concepts G_ST80_XX_00558 ■ Overview Customized hardware Individual in design and configuration Customized design • Inscription or printed logo, e.g. on the front cover of the enclosure, matches your corporate design requirements • Custom color design of enclosure, individual enclosure components, e.g. enclosure front and front cover – for perfect optical integration of the PC in the operating environment Customer-specific configuration • Optimization of the computer configuration – corresponding to the requirements of your application, e.g. with or without PROFIBUS interfaces or optical drives • Optimal selection of the required components - with regard to performance capability, long-term availability and compatibility, e.g. processor, fan, work memory, etc. • Installation of the hardware you specified – e.g. third-party hardware such as drives and PC cards or customized, supplied hardware Customized software – operating systems, drivers, image Generation of operating systems • E.g. for Windows XP embedded, • and the RMOS3 real-time operating system from Siemens • For customer-specific preinstalled LINUX operating system1) Integration and installation of driver software and image storage • E.g. for additional plug-in cards, controllers and memory media • For complete, turn-key systems 1) Suitable for specific LINUX versions in accordance with the specifications of the Siemens manufacturer's declaration "Suitable for LINUX", see http://www.siemens.com/simatic-pc/suitable-for-linux © Siemens AG 2013 Customized Automation Introduction Customized adaptations ■ Application (continued) Customized service and support Pre-sales and after-sales support • Requirements analysis, concept creation, solution generation • Competent project support from the offer through to delivery and beyond • Individual repair concepts with worldwide Siemens service network with 190 branches and 33 repair centers • 24-hour product support over the SIMATIC Hotline System test of hardware and software, e.g. • EMC chamber – Test for electromagnetic compatibility • Thermal simulation – Thermal simulation and heat imaging camera to detect heat pockets • Heat test – Testing of all components in a 36-hour heat test at 40 degrees Celsius in a heated cabinet • Stress test – Test for high vibration/shock loading, specially for CPU, graphics, memory, modules, etc. Product Equipment Data (PED) • Online tool PED (www.siemens.com/ped) – For easy, systematic identification and management of device components. It shows you the most important components of your equipment (delivery status) easily and quickly and supports you worldwide in the event of a servicing requirement with the procurement of suitable replacement parts. Individual logistics solutions • Kanban delivery – We supply according to the requirements of the organization units in the production process of our customers who organize their production process control in accordance with the Kanban principle. This shortens the throughput time and reduces inventories. • Just in time – We reduce the inventories and throughput times of our customers by supplying the hardware manufactured customer specifically at exactly the time when they need them in the production process or in the logistics chain • Reusable packaging – Better than recycling! The packaging is collected from our customers after the specially manufactured hardware has been unpacked and reused for transporting the next delivery. Packaging material is saved to the advantage of our customers and the environment. ■ More information You can find further information at: Internet: http://www.siemens.com/customized-pc Email: customized-pc.automation@siemens.com "Tempesting" (SITEMP) • TEMPEST (Temporary emanation and spurious transmission) – For protecting compromising data from listening-in attacks by means of electromagnetic radiation • Series measurements and certification of special PC hardware according to the standards of the German Institute for Safety in Information Technology (BSI) for radiation safety • E.g. PC for processing highly sensitive research and development data Certification and approval of hardware and software – e.g. UL and CE industry certification On-site service – e.g. for plant failure, on-site repairs, product upgrades Customized logistics 6 Availability tailored to your requirements • Configuration and design freeze – Individual availability agreements for unchanged hardware and software versions of the products (image compatibility) • Replacement parts in centralized or decentralized spare parts storage – For individually agreed periods or, where applicable, last-time buying and storage of components • License authorization for discontinued software, e.g. for Microsoft operating systems such as Windows NT, MS DOS Tailor-made right down to the detail • Change notices – Individual agreements for customer information management, e.g. product discontinuation, version updates, phase-out announcements • Individual labeling – On the industrial PC and/or product packaging, e.g. customized item/device/inventory numbers, warehouse barcodes or packing and safety instructions • Supply of accessories – e.g. adapter cables, keyboards or accompanying documents and manuals Siemens ST 80 / ST PC · 2013 6/5 © Siemens AG 2013 Customized Automation Customized hardware Customized hardware ■ Overview For this purpose, we simply combine the standard components, the customized components, and the additionally required software function expansions into a SIMATIC OEM device, as with a modular system. Customized products are modified SIMATIC HMI standard products A distinction is made according to the degree of hardware modification: • Design products • OEM products • Turnkey products The Open Platform Program is available for customized software solutions. With these possible modifications, products are planned for special customer requirements in the various industries. • Customized products from various sectors Further information can be found on the Internet at: http://www.siemens.com/hmi-oem Proportion of customized modifications on the individual product types: Standard Products Design Products 15% OEM Products However, new OEM products can frequently be based on already implemented OEM products for efficiency and cost savings (see product examples). The end product is then represented as a customized modification of an existing OEM product. 25% Turnkey Products G_ST80_XX_00296 10% Customized hardware: Design products Customized design means modifying the design and visual impact of the SIMATIC, SIMATIC HMI and SIMATIC IPC products for seamless adaptation into the customer's individual machine and plant design and special operator philosophy. 6 The modification options are: • Changing the company logo and and device type designation • Changing the keyboard color scheme, the key labeling, or the key symbols • Changing the enclosure color (front frame) Design products are fully compatible with the standard products in technology and functionality, and can thus be fully integrated into the Totally Integrated Automation environment. Identical technology enables, for example, replacement using standard devices in the event of a fault in case the machine or plant supplier does not currently have a customized product in the spare parts warehouse. OEM products Product modifications for OEM (Original Equipment Manufacturer) customers are suitable for individual, industrial automation solutions that cannot be fulfilled with the help of standard products, or can only be handled with design-modified panels. OEM products are individual solutions based on SIMATIC standard components. They are specified, offered, developed and supplied individually in consultation with the customer. 6/6 Siemens ST 80 / ST PC · 2013 Modification options: • Changes in the keyboard layout, key size/design and key arrangement • Freely definable front dimensions and mechanical components • Integration into enclosure for desktop use or support arm mounting • Different processes and memory media • Different display technologies, sizes and resolutions • Distributed configuration • Additional modules or interfaces • Freely selectable Windows versions as operating systems, pre-installed SIMATIC software packages Our OEM devices are available in every performance class starting from OEM Push Button Panels, through Text Displays, Touch and Operator Panels, right up to multifunctional platforms (MPs) and PCs in rack/box/panel versions with extensive changes to hardware, equipment and installed software. Customized OEM products are developed and produced in various stages in accordance with quality standards. Turnkey products Customized turnkey products are ready-to-install and ready-touse products from a single source that have been combined and assembled to customer specifications and in accordance with the specific technical requirements of HMI products. With the turnkey products, the HMI products are tested and supplied, e.g. as complete operator stations, that is, mounted and wired in special enclosures, and installed with the specified software: • Optimized HMI operator station: ergonomic, functional, certified and tested • Optimal mechanical installation of the devices with defined high degree of protection • Flexible in installation and wiring • Variable mounting options (support arm, stand, wall-mounting) • Certified in accordance with VDE, CE and UL (in accordance with agreements and statutory conditions) • Vibration-tested and shock-tested • Packaged for safe transport • Tested heat balance with passive cooling and with specified ambient temperature • Customer-specific software suite with electronic software release management Customized SIMATIC turnkey products offer standard product quality from a single source and are ready-to-install and readyto-use. © Siemens AG 2013 Customized Automation Customized hardware Design products ■ Overview The following applies for implementation in Digital Express design: • Without contractual obligation • Even small ordering quantities • Significantly reduced implementation time • Photo-realistic print quality The SIMATIC HMI products with customer-specific design are completely identical to the standard products in respect of technology and function. This similarity makes it possible to respond flexibly to almost any need situation. In this way, a machinery and plant supplier can quickly switch to standard products if in the event of a fault there are no HMI design units available in the spare parts inventory. This flexible production makes cost-effective design products possible even in small ordering quantities. The devices are manufactured in the series production factory and are subject to the same quality requirements as standard devices. The professional creation of customized designs is handled by the SIMATIC HMI Design Center. SIMATIC HMI products in individual corporate design for machines and plants are important for customers when making purchasing decisions. Seamless integration of the HMI devices in operation and ergonomics as well as in the overall machine and plant design is especially important. The HMI devices with customer-specific design fully meet these requirements. The following design changes are possible depending on the variant: • Extremely fast design implementations • Implementation of even low minimum quantities (no general agreements) • Photo-realistic design up to 600 dpi • Color gradients in the logo The following changes (design variants) are possible: • Version A: Inserting the individual company logo instead of the Siemens logo and changing the type designation • Version B: Version A + changing keyboard colors, key labels, symbols and background color • Version C: Version B + changing the frame color for the front frame • Digital Express design: Version B in photo-realistic print quality, for small quantities with accelerated execution of the project The following applies for variants A-C: • A contractually agreed minimum quantity per year is necessary • Stockpiling in accordance with contract • First deliveries approximately 8 weeks after design start The following services are offered to the customer: • Support in the selection of suitable design variants • Direct, specialist coordination and customer consultation in the selection of appropriate typefaces, colors, and standard symbols, e.g. to optimize machine operation • Creation of a customer-specific design draft • Short response times, first design draft around 5 days after design start • Obtaining required customer approval There are no one-off project costs for these services of the SIMATIC HMI Design Center (see "Additional information" for details). A quotation will be made for any further changes and consultation services. Regarding customized design, it is also possible to match the colors of various SIMATIC HMI design devices in order to achieve a uniform corporate identity. The associated costs will be calculated according to actual requirements. ■ Benefits • Seamless adaptation to the customer's machine and plant design and special operating philosophy • No restrictions in ergonomics compared with a standard product • Even small quantities of design products may be ordered • Replaceable and fully compatible with the standard devices in terms of: - Functions and interfaces - SIMATIC HMI configuration software - Enclosure and installation dimensions - Logistics and service, identified repairs • UL and CE certification, more upon request Selected SIMATIC HMI Touch devices are available in Digital Express design thanks to adapted production procedures. Siemens ST 80 / ST PC · 2013 6/7 6 © Siemens AG 2013 Customized Automation Customized hardware Design products ■ Ordering data According to size of display Device type Order No. of basic product Minimum order quantities Normal design Variant A/B Minimum order quantities per order Express design HMI TP700 Comfort 6AV2124-0GC01-0AX0 75 3 TP 177 6" DP mono 6AV6642-0BC01-1AX1 TP 177 6" DP/PN color 6AV6642-0BA01-1AX1 9 inch HMI TP900 Comfort 6AV2124-0JC01-0AX0 75 3 12 inch HMI TP1200 Comfort 6AV2124-0MC01-0AX0 50 3 MP 377 12" Touch 6AV6644-0AA01-2AX0 MP 277 10" Touch 6AV6643-0CD01-1AX1 HMI TP1500 Comfort 6AV2124-0QC02-0AX0 MP 377 15" Touch 6AV6644-0AB01-2AX0 HMI TP1500 Basic color PN 6AV6647-0AG11-3AX0 50 on request 19 inch HMI TP1900 Comfort 6AV2124-0UC02-0AX0 50 on request 22 inch HMI TP2200 Comfort 6AV2124-0XC02-0AX0 50 - HMI KP8 PN, Key Panel 6AV3688-3AY36-0AX0 on request on request HMI KP8F PN 6AV3688-3AF37-0AX0 on request on request HMI KP300 Basic mono PN 6AV6647-0AH11-3AX0 200 on request HMI KTP400 Comfort 6AV2124-2DC01-0AX0 100 on request HMI KP400 Comfort 6AV2124-1DC01-0AX0 100 on request HMI KTP400 Basic mono PN 6AV6647-0AA11-3AX0 200 on request HMI KP700 Comfort 6AV2124-1GC01-0AX0 75 on request HMI KTP600 Basic mono PN 6AV6647-0AB11-3AX0 200 on request HMI KTP600 Basic color DP 6AV6647-0AC11-3AX0 200 on request HMI KTP600 Basic color PN 6AV6647-0AD11-3AX0 200 on request 9 inch HMI KP900 Comfort 6AV2124-1JC01-0AX0 75 on request 12 inch HMI KP1200 Comfort 6AV2124-1MC01-0AX0 50 on request HMI KTP1000 Basic color DP 6AV6647-0AE11-3AX0 75 on request HMI KTP1000 Basic color PN 6AV6647-0AF11-3AX0 75 on request HMI KP1500 Comfort 6AV2124-1QC02-0AX0 50 on request Touchscreen 7 inch 15 inch 4 4 3 3 50 on request 3 Key 3 inch 4 inch 7 inch 15 inch 6 6/8 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Customized Automation Customized hardware Design products ■ Ordering data (continued) According to size of display Device type Order No. of basic product Minimum order quantities Normal design Variant A/B Minimum order quantities per order Express design 7 inch IPC277D Touch depending on the configuration 50 2 9 inch IPC277D Touch depending on the configuration 50 2 12 inch Flat Panel Touch or Monitor depending on the configuration 50 on request IPC277D Touch depending on the configuration 50 2 Panel PC Touch or Key depending on the configuration 50 on request ITC1200 6AV6646-1AA22-0AX0 75 on request Flat Panel Touch or Monitor depending on the configuration 50 on request Flat Panel Touch PRO 6AV7861-5TB10-1BA0 50 on request IPC277D Touch depending on the configuration 30 on request IPC477C Touch PRO depending on the configuration 30 on request IPC477C Touch depending on the configuration 30 2 IPC677C Touch depending on the configuration 30 2 (USB) Panel PC Touch or Key depending on the configuration 30 on request ITC1500 6AV6646-1AB22-0AX0 30 on request Flat Panel Touch or Monitor depending on the configuration 30 on request Flat Panel Touch PRO 6AV7861-6TB10-1BA0 30 on request IPC477C Touch PRO depending on the configuration 30 2 Panel PC Touch depending on the configuration 30 on request ITC1900 6AV6646-1AC22-0AX0 30 on request ITC2200 6AV6646-1AD22-0AX0 30 on request Touch/Monitor/Key 15 inch 19 inch 22 inch For all other products not listed here, please inquire directly. ■ More information Ordering information Processing Explanation of the tables with selection and order data: A special order processing is required for the customized design. Various approval steps by the customer are to ensure that the end product meets the customer's expectations. The orders are processed, like standard orders, via the Logistic Center Nuremberg (LZN). Orders and deliveries of 1 unit or more depending on the version or contract are possible! "Device type" and "Order No. of the associated basic product" • "Type specification" and "Order No." of the HMI standard product to be modified. • Start of delivery of a design variant cannot commence less than 4 months after the start of delivery of a standard device. "Design variant" • Type of modification required, according to design variants "Minimum quantity" • In order to be able to offer high-quality products at a competitive price in the global market, there must be a lower limit to the annual quantity and a minimum order quantity. • The possible design devices with the associated minimum quantities are listed in the overview tables. 6 Repairs/spare parts storage Only identified repairs are carried out. The customer-specific spare parts required for this purpose (device front panels) are to be stored and made available by the customer on expiry of the warranty period or on termination of supply. Contacts Please contact your local/national SIMATIC HMI representative (visit our Internet site for more information) Prices and one-off costs Further information can be found on the Internet at: An additional amount over the price of the standard device is charged for the customized design device. http://www.siemens.com/hmi-oem There are no additional costs for a one-off design (without Change Requests). Siemens ST 80 / ST PC · 2013 6/9 © Siemens AG 2013 Customized Automation OEM products OEM products ■ Overview ■ Benefits • The SIMATIC HMI OEM concept represents "customizing at its best": Your requirements, based on sector and application knowhow, combined with our experience in the development of HMI devices of all performance classes, result in tailor-made solutions at a fair price. • Customized OEM products are developed in defined stages in accordance with quality standards and produced using standard plant facilities - always in close cooperation with the customer. • Users in various industries, including regenerative energies, the automotive industry, the food, beverages and tobacco industries, the oil and gas industry, as well as in the plasticsprocessing industry and others are benefiting from our experience of delivering tried and tested OEM versions and industry standards. 6 • HMI product modifications for OEM customers are suitable for complex industrial automation tasks that cannot be implemented using standard products. • OEM devices are available in all performance classes: from OEM Push Button Panels through Micro Panels, Panels and Multi Panels right up to Panel PCs as well as Rack and Box PCs - with far-reaching changes in hardware, equipment and software. • The following modifications are possible: - Changes to keyboard layout: Number of keys, key size/design and key layout - Freely definable front dimensions and mechanical components - A variety of processors for customized performance - A variety of memory media and capacities - Installation of function cards - Display technologies, sizes and resolutions - Options such as direct key modules - Distributed configuration of Panel PCs - Housings for desktop, stand or support-arm versions (operator station concept) - Additional modules or interfaces, of course always complete with the necessary device drivers - Selectable Windows operating systems - Preinstalled SIMATIC software and customized software packages - additional functions due to PCIe slot - Frontplate design in color and labeling of the interfaces - Large number of interface options in the configurator in a very small space 6/10 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Customized Automation OEM products Flexible front design concept for HMI products ■ Overview ■ Benefits The flexible front-mounting concept allows customized HMI solutions based on the field-proven SIMATIC components. A project using the flexible front-mounting concept is the obvious choice especially for the following customer requirements: • Customized integration of operator elements and display systems • High integration density of SIMATIC products • Demand for customized design and layout • Demand for optimal integration into plants and machinery • Compact design as stand-alone product in enclosure • Compact design as built-in unit at the machine level • Use of field-proven components and thus also optimized timeto-market These requirements can be implemented for the customer by means of a flexible front-mounting concept. MP 377 15" Touch OEM according to flexible front-mounting concept for injection molding machines Customer requirements with regard to HMI devices are extremely diverse. The flexible front-mounting concept makes it possible to meet these diverse customer-specific requirements. The flexible front-mounting concept enables customized front design as well as customized layout of the operator elements. The SIMATIC products form the technical basis of a device developed according to the flexible front-mounting concept. The diversity of the standard products enables integration from the small 6" Flat Panel right up to high-performance PC technology. The customer's own, typical operator philosophy can also be optimally implemented since the flexible frontmounting concept offers the wide range of operator elements – from the classic 3SB operator elements, through short-stroke keys, right up to membrane keyboards. The general conditions for a project using the flexible frontmounting concept are: • Minimum unit quantity 100 p.a. • Project agreement - With unit quantity start-up forecasting and annual unit quantities for the project - for funding development costs - Key project dates and standard start-of-delivery dates - Logistics with delivery times ■ Application The industrial environment imposes diverse requirements on technology and design. Thanks to its variable and modular approach, the flexible front-mounting concept opens up diverse options for re-combining SIMATIC standard components in a compact device configuration with individualized design and layout. The possible uses are thus diverse and universal. The flexible communication options with PROFIBUS or PROFINET facilitate integration into new or existing machine concepts. Fail-safe operation can be implemented by using PROFIsafe components. To meet individual customer requirements, a device built in accordance with the flexible frontmounting concept can be designed as a built-in device or as a stand-alone unit. If designed as a stand-alone unit, care is taken to make the enclosure slimline and modern in appearance. 6 Siemens ST 80 / ST PC · 2013 6/11 © Siemens AG 2013 Customized Automation OEM products Flexible front design concept for HMI products ■ Design ■ More information The flexible design and the use of standard SIMATIC products make it possible to meet just about every technical requirement with regard to customized HMI. Components that can be combined to form an individualized HMI are listed below: Quotation preparation Basic devices: • Flat Panels with different screen diagonals • Thin Client • Comfort Panel • Panel PC Determining: • One-time project costs • Costs for sample devices/prototypes • Standard unit prices • General conditions (product agreement) Operator control: • Touch functionality • Keys functionality with - 3SB elements - Short-stroke keys - Membrane keys (also illuminated) • Keyswitches etc. There must be a minimum limit to the annual unit quantity/ purchase quantity (minimum quantity per version: from 100) and this must be agreed with the project customer. Customized products can only be ordered in conjunction with a product agreement. A customer-specific order number is allocated during the product agreement process. Additional elements: • High-speed keys via PROFINET • Emergency stop (also PROFIsafe) • Front USB etc. Design: • Stand-alone (IP65 at front, <= IP54 at rear) • Built-in unit (IP65 at front; IP20 at rear) • Slimline enclosure design Device connection: • With support arm via VESA 100 on rear of enclosure • Connected at the edges using hinges • Installation in machinery Design: • Customized design • Customized key layout • Customized symbols and logos Product specification in accordance with customer requirements. Quotation drafted by SIMATIC HMI specialists. Contacts Please contact the HMI representatives of your Siemens sales office/national company. Additional information in the Internet is available at: http://www.siemens.com/hmi-oem Flexible front-mounting concept project development and service Customized projects using the flexible front-mounting concept are developed and produced in different steps in accordance with quality standards. Prototypes are created to test products. Once the devices have been approved by the customer, they undergo certification and are introduced into the production process. Devices are produced in standard product factories, ensuring observation of customer quantity forecasts. For this purpose, individual quantity forecasts are exchanged with the customer. In the event of questions and problems, customers can contact our worldwide 24-hour SIMATIC Customer Support. Customized products can only be ordered in conjunction with a product agreement. The following points are defined in the product agreement: • Delivery and pricing • Logistics - annual volume, purchase quantity, delivery batch volumes • Spare parts • Service • Repairs/spare parts storage 6 The repair concept is also agreed with the customer. The necessary customized spare parts (device fronts) are defined here and offered to customers for their products after completion of delivery. 6/12 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Customized Automation OEM products MP 277 8" Touch control console ■ Overview OEM MP 277 8.4" Touch ■ Technical specifications • • • • • • Rugged die-cast aluminum housing 8.4'' TFT display 800 x 600 pixel resolution Operation by means of touch screen and optional joystick Customized application and customized WinCE image Degree of protection on front: IP65. Option • Different housing color ■ Ordering data OEM MP 277 8.4" Touch ■ Benefits • • • • • • • Heavy-duty, die-cast aluminum housing Easy mounting on patient table with clamping device Low space requirements Extremely good readability Simple operation Joystick can be connected optionally on left or right Ethernet communication Order No. On request Customized products can only be ordered in conjunction with a product agreement. The following points are defined in the product agreement: • Status: Released for delivery • Project runtime: None • Non-recurring costs: None • Minimum quantity: 200 ■ More information Additional information is available in the Internet under: http://www.siemens.com/hmi-oem ■ Application The OEM MP 277 8.4" Touch is suitable for use as a control console for coronary angiography systems in the medical field. 6 Siemens ST 80 / ST PC · 2013 6/13 © Siemens AG 2013 Customized Automation OEM products SIMATIC HMI Net Panel ■ Overview ■ Benefits Professional display system for continuous, maintenance-free operation The SIMATIC HMI Net Panel is multifunctional when it comes to rugged, large-scale display applications for industrial areas, as it is ideal for production plants and control stations or for trade fairs and information points visited by the public. The Net Panel is based on a reliable industrial PC of the SIMATIC IPC series and is designed for 24-hour, maintenancefree operation in an industrial environment. It is extremely flexible in operation and can be used as a stand-alone solution or in the network as a complete industrial display system comprising several Net Panels. For applications that require audio output, variants of the Net Panel are available with audio modules and speaker equipment. Remote Control for setting up the SIMATIC HMI Net Panel The Remote Control Software included in the scope of delivery allows the Net Panel to be operated either locally or via the network. It enables the brightness and volume to be adjusted and the backlight to be switched off. 6 For self-diagnosis the device temperature can be indicated. The Remote Control software allows the function to be shut down to prevent burn-in effects (anti-image sticking). The anti-image sticking function should, however, only be deactivated when adequate measures have been implemented on the Net Panel to prevent image sticking. Remote Operate as client/server solution for industrial display systems (optional) When Remote Operate is installed, four virtual graphics cards can be set up on one IPC and presented as extended desktops. On every SIMATIC HMI Net Panel, a Remote Operate client is installed that is assigned to a virtual graphics card. The different screen contents are distributed to the virtual graphics adapters using the HMI software WinCC. If the Net Panel is equipped with sound, MP3 and Wave files can be sent to a specific Net Panel where they can be played, using an easily accessible function. 6/14 Siemens ST 80 / ST PC · 2013 • High degree of system availability due to maintenance-free industrial design with IP65 degree of protection for continuous 24-hour operation • High security of investment due to rugged industrial products from SIMATIC that will remain available over the long term • Reduced costs through low-wear and power-saving LED backlight and anti image sticking function • Easy, cost-efficient integration in a standard network environment without VGA/DVI/HDMI extensions or expensive video signal extenders • Optionally available with audio module and loudspeaker for sound output • Flexible mounting on support arm systems, wall and ceiling, as well as back-to-back mounting and with an angle of inclination of up to 20° from the vertical • Remote Control Software (locally on the device and remotely from the network) for the easy parameterization of - Brightness - Deactivation of backlighting - Status messages of display - Speaker control • Supported by WinCC flexible 2008 SP2 or higher (IPC427C with 1920 x 1080 resolution) ■ Application The SIMATIC HMI Net Panel is designed for demanding largescale displays in the industrial environment. It is based on rugged, reliable PC technology with interfaces for easy, cost-efficient integration in existing networks and offers maximum flexibility for positioning and mounting. The large LCD display with LED backlight, round-the-clock operation, and full PC openness make the large-scale display ideal for use as an industrial manufacturing display, add-on system, multimedia display, process visualization system, railway station and airport display (check-in, gate, baggage claim, advertising display) or at trade fairs, in shopping centers, hotels, museums and more. ■ Design The SIMATIC HMI Net Panel is a rugged display system with an integrated industrial PC and optional audio and loudspeaker equipment. • LCD display with 1920 x 1080 pixel full HD resolution • Power saving and long-life LED backlight • Integral SIMATIC industrial PC • Rugged and attractive device design with reduced enclosure depth • Degree of protection IP65 all-round, industry compatible • Solid, shatterproof front pane of 6 mm laminated glass • Anti-glare front pane resistant to welding beads • Safety eyebolts (removable as required) for additional protection against dropping in suspended installations • Optional: adapter for Rose & Krieger FSK 50 support arm system • Integrated wide-range power supply • Rear connector for 1x USB (with IP65 protective cap), 1x Industrial Ethernet (M12 4-pin with protective cap) • Rear Quick-On connection for integrated 100 - 240 V power supply (connector included in scope of delivery) • Rear status indicator © Siemens AG 2013 Customized Automation OEM products SIMATIC HMI Net Panel ■ Technical specifications SIMATIC HMI Net Panel SIMATIC HMI Net Panel Size 46" (116 cm) LCD TFT 46" (116 cm) LCD TFT Resolution 1920 x 1080 Full HD (16:9) 1920 x 1080 Full HD (16:9) Colors 16.7 million colors 16.7 million colors Reading angle +/- 178° +/- 178° Backlighting LED backlight LED backlight Brightness Typically 400 cd/m² Typically 400 cd/m² Processor Celeron M 1.2 GHz Core2 Solo 1.2 GHz Main memory 1 GB 4 GB Mass storage Compact Flash 4 GB 250 GB hard disk Operating system Windows Embedded Standard 2009 Windows Embedded Standard 2009 Enclosure design Industry-compatible steel enclosure, black, powder-coated Industry-compatible steel enclosure, black, powder-coated Glass front Shatterproof front pane of 6 mm laminated glass, anti-glare, resistant to welding beads Shatterproof front pane of 6 mm laminated glass, anti-glare, resistant to welding beads Audio module 2x 15 W audio module 2x 15 W audio module Loudspeakers 1 pair, mounted to left and right, BOSE or alternatively Visaton 1 pair, mounted to left and right, BOSE or alternatively Visaton USB 2.0 1x at rear (with IP65 protective cap) 1x at rear (with IP65 protective cap) Ethernet 1x Industrial Ethernet, D-coded (M12 4-pin with protective cap) 1x Industrial Ethernet, D-coded (M12 4-pin with protective cap) Power supply 100 - 230 V AC Quick-On plug connector 100 - 230 V AC Quick-On plug connector Keyboard; mouse Connectable via USB interface (optional USB hub recommended for commissioning) Connectable via USB interface (optional USB hub recommended for commissioning) Degree of protection IP 65 all-round; IP54 when USB is plugged in IP 65 all-round; IP54 when USB is plugged in Vibration load during operation 1g outline specification 1g outline specification Shock loading during operation 5g outline specification 5g outline specification Ambient temperature during operation 5…45°C for 24 h operation 5…45°C for 24 h operation CE CE External dimensions (W x H x D in mm), weight 1138 x 681 x 130; approx. 55 kg 1138 x 681 x 130; approx. 55 kg External dimensions (W x H x D in mm) with BOSE loudspeaker, weight 1410 x 681 x 130; approx. 58 kg 1410 x 681 x 130; approx. 58 kg External dimensions (W x H x D in mm) with Visaton loudspeakers, weight 1565 x 681 x 130; approx. 57 kg 1565 x 681 x 130; approx. 57 kg HMI software Supported by WinCC flexible 2008 SP2 or higher Supported by WinCC flexible 2008 SP2 or higher Remote Control Software For adjustment and control, locally or via network For adjustment and control, locally or via network Continuous glass front with narrow protective frame Continuous glass front with narrow protective frame Auto-refresh function for anti image sticking Auto-refresh function for anti image sticking 2-point mounting, M8 on left and right sides of enclosure, 75 mm spacing 2-point mounting, M8 on left and right sides of enclosure, 75 mm spacing 2x removable safety eyebolts on top of enclosure 2x removable safety eyebolts on top of enclosure Display PC configuration General features Audio (optional) Interfaces Ambient conditions Conformity Approvals 6 Dimensions Software Special features Siemens ST 80 / ST PC · 2013 6/15 © Siemens AG 2013 Customized Automation OEM products SIMATIC HMI Net Panel ■ Ordering data SIMATIC HMI Net Panel Intelligent large-scale display; 1920 x 1080 full HD widescreen; 1 x Industrial Ethernet interface and 1 x USB on the rear; Windows Embedded Standard 2009; remote control software; enclosure design according to IP65, if plugged in at the rear IP54; includes Quick-On connector for 100 - 230 V power supply; CE • Preferred type: 46" screen diagonal, IPC Celeron M 1.2 GHz, 1 GB RAM, 4 GB CF Card, without speakers, without audio module • 46" screen diagonal, IPC Celeron M 1.2 GHz, 1 GB RAM, 4 GB CF Card, with Visaton speaker, with audio module 2 x 15 W • 46" screen diagonal, IPC Celeron M 1.2 GHz, 1 GB RAM, 4 GB CF Card, with BOSE speaker, with audio module 2 x 15 W • 46" screen diagonal, IPC Core2 Solo 1.2 GHz, 4 GB RAM, 250 GB hard disk, without speakers, without audio module • Preferred type: 46" screen diagonal, IPC Core2 Solo 1.2 GHz, 4 GB RAM, 250 GB hard disk, with Visaton speakers, with audio module 2 x 15 W • Preferred type: 46" screen diagonal, IPC Core2 Solo 1.2 GHz, 4 GB RAM, 250 GB hard disk, with BOSE speakers, with audio module 2 x 15 W Order No. Support arm systems Various support arm systems for ceiling, back-to-back, wall or stand mounting are offered by Rose & Krieger. 6AV7426-0AA12-0BA0 6AV7426-0AA12-1BA0 6AV7426-0AA12-2BA0 6AV7426-0AD35-0BA0 6AV7426-0AD35-1BA0 6AV7426-0AD35-2BA0 ■ More information Customized modification options on request. Recommended support arm system from Rose & Krieger. 6 SIMATIC HMI specialists define the product modifications precisely in accordance with customer requirements. This is followed by drafting of a quote with: • Non-recurring costs • Prototype costs • Standard unit prices • and the marginal conditions in the form of a product agreement (e.g. minimum quantity). The defined device can then be ordered easily using this product agreement and a customized order number. 6/16 Order No. Accessories Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Customized Automation Turnkey products Turnkey products ■ Overview Turnkey products are ready-to-install and ready-to-use SIMATIC HMI products. The benefits are found in the optimal mechanical installation of the devices, ergonomic, functional and with tested heat balance, and flexible in installation. Products • HMI operator stations HMI devices with display diagonal of 10" and more are installed in selected enclosures to suit the function. HMI operator stations can be used wherever it is not possible to install human machine interface devices in a control cabinet or direct at the machine, and where off-the-shelf, turnkey products can save on engineering overhead. Installation of a customized image in the devices is possible (ready-to-run). Customized SIMATIC turnkey products offer standardized quality from a single source. • Backplane cover The backplane cover enables the enclosure of flat HMI products such as the HMI IPC 477C or MP 377. The backplane cover is provided with a VESA flange on the rear. More operator elements can be installed on the side in additional enclosures. 6 Siemens ST 80 / ST PC · 2013 6/17 © Siemens AG 2013 Customized Automation Turnkey products HMI operator stations for turnkey products ■ Overview ■ Application Turnkey products are SIMATIC HMI products or "ready-to-run" operator stations, i.e. pre-configured, ready for installation and ready-to-run SIMATIC Panels Thin Client, Multi Panels or Flat Panels and Panel PCs, installed in customer-specific enclosures. Examples are Multi Panels fitted in customized die-cast aluminum enclosures with external keyboard; with installed application software, ready for connection, and ready-to-run. Complete HMI operator stations can be used wherever HMI devices cannot be installed in a control cabinet or directly at the machine. Operator stations are suitable for: • Industrial application • Near-industrial application • Use in secondary applications in food, beverage and tobacco production • Stainless steel version in the primary areas of the food, beverages and tobacco industries HMI turnkey products can be used wherever prefabricated, ready-to-run hardware and software products can be used to save on engineering. ■ Design Application example: Multi Panel in aluminum enclosure with operator controls, two-tier and with external keyboard ■ Benefits High industrial capability thanks to an all-round rugged, tried and tested design: • Ergonomic, technically proven and certified solutions ready for operation • Safe operation even under difficult environmental conditions • Temperature-tested and temperature-monitored • Suitable even for special industries, e.g., stainless steel versions for the food, beverages and tobacco industries • For high availability and a safe return on your investment • Siemens quality support, service and repair 6 The following issues are considered when developing the HMI operator stations: • Optimal HMI product installation technology to eliminate thermal hotspots and heat pockets in the housing • Calculation of actual maximum permissible ambient temperature of the entire operator station in continuous duty at location of use Data takes into account device heat dissipation values • Ensuring the adherence to the load limits for rotary mass storage systems and large displays verified by shock and vibration tests on the entire operator station during operation • Adherence to legal regulations (certifications) • Determination and testing of required degrees of protection and EMC measures • Assurance of surface quality along with its abrasion and chemical resistance • To the greatest possible extent, passive technology provides the basis for all measures to improve the suitability of use of the operator stations in specific environments (e.g., no active air conditioning). The aim is to ensure durability and fault-free operation with minimum maintenance. 6/18 Siemens ST 80 / ST PC · 2013 The HMI operator station concept is based on a modular system where HMI devices are built into selected enclosures to suit the functionality. • HMI device enclosure for all-round protection (IP65) • Mounting possible on stand or supporting bracket • Rotation possible by means of adjusting elements • Connection option for external keyboard and mouse • Installation option for specific hardware components Ambient temperature for turnkey products The ambient temperature is always lower than the max. permissible ambient temperature of the HMI products (temperature values in Manual) installed in the operator station housing. Depending on the components and version (e.g. according to heat dissipation), permissible ambient temperatures around the operator station will vary between 5°C and 40 °C. Higher operator station ambient temperatures can be achieved by applying additional cooling measures. ■ Function • • • • • • • • • Fatigue-free, fast operation Operator station can be quickly adapted to different operators Coherent, easy-to-learn operator philosophy Rugged against shocks and vibrations in operation Suitable device selection (SIMATIC HMI devices from 10“ display) Ensuring the data transfer and access to drives and interfaces Direct operation of the machine (conventional operator elements for direct connection to machine units) Simple alphanumeric input Cleaning agents taken into account © Siemens AG 2013 Customized Automation Turnkey products HMI operator stations for turnkey products ■ Ordering data ■ More information Ordering notes Contacts Product specifications and quotation preparations • Product specification according to customer requirements • Quotation preparation by SIMATIC HMI specialists, specification of: - one-time project costs - costs for sample devices/prototypes - standard unit prices - general conditions (product agreement) Please contact the HMI representatives of your Siemens sales office/national company. http://www.siemens.com/hmi-oem Processing Customized turnkey products are developed and produced in various stages in accordance with quality standards. Prototypes are created to test products. Once the devices have been approved by the customer, they undergo certification and are introduced into the production process. Devices are produced using standard plant facilities, ensuring observation of customer quantity forecasts. For this purpose, individual quantity forecasts are exchanged with the customer. In the event of questions and problems, customers can contact our worldwide 24-hour SIMATIC Customer Support. This is complemented by a special OEM After Sales Support service. Customer-specific project hotlines can be set up for bulk quantity customers. Customized products can only be ordered in conjunction with a product agreement. The following points are defined in the product agreement: • Delivery and pricing • Logistics - annual volume, purchase quantity, delivery batch volumes • Spare parts • Service Repairs/spare parts storage Only identified repairs are performed. The required customerspecific spare parts (device fronts) are to be stored and provided by the customer upon delivery completion. 6 Siemens ST 80 / ST PC · 2013 6/19 © Siemens AG 2013 Customized Automation Customized software Customized software ■ Overview Customized software Remote Operate Software In the case of customer-specific products, the software can also be individually installed. This includes the generation of operating systems and also the integration and installation of driver software and images – for complete, turnkey systems. The HMI Remote Operate Software is an industrial remote control system based on Ethernet. The customized software suite comprises: • Generation of operating systems - for Windows XP embedded, for example - and the RMOS3 real-time operating system from Siemens - for customized LINUX installation • Integration and installation of driver software and pre-installed images - for additional cards, controllers, or memory media, for example - for completely turnkey systems In addition, customized software products based on our experience in the industrial automation offer an opportunity to set up multi-user systems and industrial remote operation and the possibility of integrating SIMATIC S7 into building automation: 6 6/20 Siemens ST 80 / ST PC · 2013 The software (server) enables the creation of a multi-user system with HMI IPC. Up to 6 operator stations (slaves) based on clients with MP 377 and HMI IPCs. The clients can also be assigned to several servers. KNX/EIB2S7 Bus systems for building management systems, such as KNX/EIB, and a host of associated components, are used for automation of building systems. While controllers for the room level are used for local automation, field-proven industrial components like SIMATIC are resorted to in the case of more complex, higher-level automation. Communication between the automation levels takes place over Ethernet using special KNXnet/IP interfaces. The KNX/EIB2S7 software package provides blocks for communication between SIMATIC S7 and building automation components. This means message frames of the KNX bus can be processed in a SIMATIC controller. © Siemens AG 2013 Customized Automation Customized software Remote Operate Software ■ Application Remote Operate Software Remote Operate Clients PD[&OLHQWVSHU6HUYHU 3DQHO3& 5HPRWH2SHUDWH 035HPRWH2SHUDWH 5HPRWH2SHUDWH 3& *B67B;;B ,QGXVWULDO(WKHUQHW 5HPRWH2SHUDWH 3& Remote Operate Server Panel PC with connected thin clients Multi-user system with Panel PCs for up to 6 operator stations based on Thin Clients with MP 377 and PC 477 • Including operator lock • In one software application with identical image contents • Identical screen resolution • Excluding server operating system • Industrial remote control - Independent of the installed software • Identical images on all devices • Automatic scaling takes place in the case of differences in screen resolution between server and client • Resolution up to 1280 x 1024 with true color • Remote Operate Server with Windows XP Professional, Windows XP embedded, or Windows 7 • Up to 6 clients on one server • Communication via Ethernet • Designed for industrial requirements - Automatic login - Simple administration - Automatic reconnect - Permanent server/client assignment - Administration of operator authorization - Can be used after Windows login - Optional key-operated switch for operator authorization Siemens ST 80 / ST PC · 2013 6/21 6 © Siemens AG 2013 Customized Automation Customized software SIMATIC KNX/EIB2S7 ■ Overview ■ Design • Software for communication between SIMATIC S7 and components of a building automation system • For using components from industrial automation in the area of building automation • Enables the integration of actuators/sensors into a KNX/EIB bus in automation solutions with SIMATIC S7 • For transferring information from the building automation system for automating a production plant ■ Benefits • Use of field-proven industrial components in the area of building automation • Use of information from building automation for automating production plants • Simple transfer of configuring data from the KNX configuring tool ETS3 • Automatic matching of KNX addresses with the associated SIMATIC addresses • Use of the SIMATIC standard ■ Application With rising energy awareness and increased requirements regarding user-friendliness and security, recent years have seen building automation facing far-reaching demands. Bus systems for building management systems, such as KNX/EIB, and a host of available components for these are used for implementing the corresponding systems. While controllers for the room level are used for local automation, field-proven industrial components like SIMATIC are resorted to in the case of more complex, higher-level automation. Communication between the automation levels takes place over Ethernet using special KNXnet/IP interfaces. The KNX/EIB2S7 software package provides blocks for communication between SIMATIC S7 and building automation components. This means message frames of the KNX bus can be processed in a SIMATIC controller. 6 The SIMATIC S7 is connected with the KNX/EIB components via KNXnet/IP interfaces. The interfaces connect the KNX/EIB bus with the Industrial Ethernet bus of the SIMATIC S7. Up to 5 KNXnet/IP interfaces can be connected to a SIMATIC S7 controller Up to 7,000 group addresses can be monitored, operated and read via these interfaces. The maximum number of group addresses depends on the controller type and the number of connected KNXnet/IP interfaces. KNX/EIB2S7 supports the following CPUs of the SIMATIC S7: • ET 200 - IM 151-8 PN/DP CPU • S7 300/400 - CPU 315-2 PN/DP - CPU 317-2 PN/DP - CPU 319-3 PN/DP - CPU 414-3 PN/DP - CPU 416-3 PN/DP • Soft PLC - SIMATIC WinAC RTX 2008 SP 1 • SIMATIC S7-300 with CP 343-1 - CPU 315-2 DP - CPU 317-2 DP - CPU 319-3 PN/DP • SIMATIC S7-400 with CP 443–1 Advanced - CPU 412-2 MPI/DP - CPU 414-2 MPI/DP - CPU 416-2 MPI • Supported KNXnet/IP interfaces: - N 146/2 IP router - N 148/221 IP interface - N 350E IP controller - N 151 IP viewer ■ Mode of operation The KNX components are parameterized with the ETS 3 software of the Konnex organization. The KNX/EIB2S7 Editor is based on the exported parameterization data of ETS3 and evaluates the group address, data type, name and description. It only remains to select the group addresses that are to be received and to mark those that are to be automatically read at initialization. Addresses are assigned automatically by the editor. The addresses can be viewed in the Editor or exported for documentation. The parameterization of the blocks necessary for the SIMATIC is generated by the Editor at the click of a mouse and can then be downloaded to the SIMATIC. The blocks contained in KNX/EIB2S7 handle the communication on the basis of this parameterization. When data is received, the current values are saved in the data blocks provided for them. The values that have been updated are then marked. Equally, there are blocks available for the selective reading and writing of values. 6/22 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Customized Automation Customized software SIMATIC KNX/EIB2S7 ■ Technical specifications Representation of the data types Data type KNX value EIS type SIMATIC data type Representation in the SIMATIC User conversion DPT1 BOOL EIS1 Bit TRUE/FALSE n DPT2 1 bit controlled EIS8 Byte MSB ([0000 00XY) LSB n X = controlled Y = Value DPT3 4 bits EIS2 Byte MSB (0000 XYYY) LSB n X = Increase/decrease Y = Step 0-7 DPT4 Char EIS13 Char DPT5 1 byte unsigned EIS14 Byte n DPT6 1 byte signed EIS14 Byte y DPT7 2 bytes unsigned EIS10 Word DPT8 2 bytes signed EIS10 Int Representation in 2s complement n DPT9 2 bytes float EIS5 Real Conversion implicit in the driver n DPT10 Time of Day EIS3 DWord MSB (0000 0000/dddh hhhh/00mm mmmm/00ss ssss) LSB n ASCII n n d = day 0 no day; 1-7 h = hour 0-23 m = minute 0-59 s = second 0-59 Important! No value check by the driver DPT11 Date EIS4 DWord MSB (0000 0000/000d dddd/0000 mmmm/0yyy yyyy) LSB n d = day 0-31 m = month 0-12 y = year 0-99 (0-89 = 2000-2089; 90-99 = 1990-1999) Important! No value check by the driver DPT12 4 bytes unsigned EIS11 DWord DPT13 4 bytes signed EIS11 D Int Representation in 2s complement n DPT14 Float EIS9 Real IEEE754 n DPT15 Access EIS12 DWord MSB (XXXX6 XXXX5/XXXX4 XXXX3/ XXXX2 XXXX1/EPDC NNNN) LSB n n 6 X = AccessCode 6-digit; 0-9; 1 nibble each E = 1 detection error (reading of access information code was not successful) P = Permission 0=not accepted; 1= accepted D = Direction 0=left to DPT16 String ■ Ordering data KNX/EIB2S7 program package EIS15 String (14) Driver evaluates header of the S7 string and then generates the 14-character long EIB string. n Order No. 6AV6643-7AC10-0AA1 Task: Software for connecting KNX/EIB components from building management systems to SIMATIC S7 Type of delivery: Editor, function blocks for SIMATIC S7, samples, documentation on CD License for Editor on USB flash drive Siemens ST 80 / ST PC · 2013 6/23 © Siemens AG 2013 Customized Automation Customized software S7 OpenModbusTCP ■ Overview ■ Design Communication with Modbus TCP stations is performed via a communications processor (CP) or via the integrated PN interface of the SIMATIC S7 CPU. SIMATIC S7-400 with CP443-1 SIMATIC S7-400 with 2x CP443-1 SIMATIC ET 200S tvki|zG {jw MODBUS participant pG l MODBUS participant MODBUS participant G_ST80_XX_00520 SIMATIC S7-300 • Software for communication between SIMATIC S7 and devices that support the Modbus TCP protocol • Expansion or upgrade of existing plants with SIMATIC automation systems • Connection of controllers and systems from different manufacturers ■ Benefits • Easy coupling of systems from different manufacturers with SIMATIC automation systems over Industrial Ethernet • No specialized Modbus know-how required • Engineering with the standard tool SIMATIC STEP 7 • Fast configuration with the help of a wizard (only available for specific versions) ■ Application 6 MODBUS is a protocol that is widely used internationally, open to all users and supported by many manufacturers. MODBUS/ TCP was developed from it for use in modern networks. This protocol is now an open Internet draft standard that was introduced by IEFT (Internet Engineering Task Force), the organization for Internet standardization. This openness means that every manufacturer and user is able to use this protocol – a possibility that many leading manufacturers have already availed of. The increasing expansion of Ethernet communication into industrial areas as well as the office environment has extended the use of MODBUS/TCP in every sector. Heterogeneous system landscapes are the typical areas of use. 6/24 Siemens ST 80 / ST PC · 2013 A SIMATIC S7 controller can communicate simultaneously with more than one Modbus TCP station simultaneously, depending on the number of connection resources of the S7 CPU. S7 OpenModbusTCP CP and Redundant V2 support the following CPs of SIMATIC S7: • S7 300 - CP 343-1 • S7 400 - CP 443-1 S7 OpenModbusTCP PN CPU supports the following CPUs of SIMATIC S7: • ET 200 - IM 151-8 PN/DP CPU • S7 300/400 - CPU 314C-2 PN/DP - CPU 315-2 PN/DP - CPU 317-2 PN/DP - CPU 319-3 PN/DP - CPU 412-2 PN - CPU 414-3 PN/DP - CPU 416-3 PN/DP • Soft PLC - SIMATIC WinAC RTX ■ Mode of operation The Modbus block functions according to the client/server principle. The client is the active station and the server is the passive station in the communication process. Data is exchanged between the communication partners by means of various different function codes. The S7 can be operated as a client as well as a server during transmission. In the initialization phase, it is determined on which S7 data blocks the Modbus registers and coils should be represented. A distinction is made between client and server functionality during cyclic operation: • If the S7 is operating as a client, when a task is activated, a Modbus message frame is generated from the specified current parameters and sent to the coupling partner over the TCP/IP connection. After the response frame has been received and the data has been checked and found to be consistent, the required actions, such as reading or writing data, will be performed. Any errors that occur during evaluation or processing will be indicated on the Modbus block. • If the S7 is operating as a server, the block waits for a response frame from the client. If a frame is received from a client, it is checked and evaluated. After the frame has been checked and found to be consistent, the response frame is generated and the required actions, such as reading or writing data, will be performed. A processed request, or any errors that occur during evaluation, will be indicated on the Modbus block. © Siemens AG 2013 Customized Automation Customized software S7 OpenModbusTCP ■ Technical specifications 2XV9 450-1MB00 2XV9 450-1MB02 2XV9 450-1MB11 Client/server functionality •/• •/• •/• Function codes 1, 2, 3, 4, 5, 6, 15 and 16 1, 2, 3, 4, 5, 6, 15 and 16 1, 2, 3, 4, 5, 6, 15 and 16 Modbus address range 0 - 65535 0 - 65535 0 - 65535 Read register 125 125 125 Write register 123 123 123 Read bits 2000 2000 2000 Write bits 1968 1968 1968 Capable of multi-instance • • • Max. number of parallel block calls • CPU-dependent • Client: No limits on block calls; max. number of blocks simultaneously active is limited by the CPU (AG_SEND) • Server: Limited by the max. number of AG_RECV calls of the CPU • Unlimited number of block calls; • Number of simultaneously established connections is dependent on the CPU • CPU-dependent • Client: No limits on block calls; max. number of blocks simultaneously active is limited by the CPU (AG_SEND) • Server: Limited by the max. number of AG_RECV calls of the CPU Connection configuration Static connections over NetPro Dynamic connections over TCON and TDISCON Static connections over NetPro Communication AG_(L)SEND/ AG_(L)RECV TSEND/ TRCV AG_(L)SEND/ AG_(L)RECV Work memory requirement FB (Client/Server) 16 KB 19 KB 20 KB approx. 1 KB approx. 1 KB approx. 1 KB Can be used in CFC/PCS 7 • • • Used with older CPs that do not support AG_CNTRL Yes - No Multiplexing of TCP connections CP-dependent - CP-dependent Redundancy functions - - Single-sided or two-sided redundancy is possible Bit memories/timers can be used No No No Data volume IDB ■ Ordering data S7-OpenModbusTCP CP Order No. 2XV9450-1MB00 Task: Software for coupling ModbusTCP devices to SIMATIC S7 via a communications processor (CP) 2XV9450-1MB11 Task: Software for coupling ModbusTCP devices to SIMATIC S7 H stations via 2 communications processors (CPs) Type of delivery: Function blocks for SIMATIC S7, example projects, documentation on CD S7-OpenModbusTCP PN CPU Order No. S7-OpenModbusTCP RED 2XV9450-1MB02 6 Type of delivery: Function blocks for SIMATIC S7, example projects, documentation on CD Task: Software for coupling ModbusTCP devices to SIMATIC S7 via the integrated PN interface Type of delivery: Function blocks for SIMATIC S7, example projects, documentation on CD Siemens ST 80 / ST PC · 2013 6/25 © Siemens AG 2013 Customized Automation Examples of sector products Examples of sector products ■ Overview SIMATIC HMI products are provided with additional features in order to facilitate optimum use in specific sectors of industry. Stainless steel front panels for the food, beverages and tobacco industry are one such example. With the exception of their front panels, the devices are identical to standard products in respect of function and technology. We can offer products for the following sectors: • Renewable energy • Automotive industry - HMI for factory automation • General machine construction • Food and beverages industry, pharmaceuticals • Oil & gas, chemicals industry and shipbuilding Customized products for various industries are developed and produced in association with a customized product agreement. 6 6/26 Siemens ST 80 / ST PC · 2013 Examples: • Application area renewable energy: - SIMATIC Rack PC with flexible expansion - SIMATIC Box PC: 627/427 with QNX • Use in the automobile industry: - HMI operator stations - Front panel for Panel PC, 15" with arrow keys on the side - Mobile Panel 277 10" Remote Operate • Application area mechanical equipment manufacture, general: - Touch and Key front panel 15" for Panel PC, resistant to honing oil - Flat Panels 10.4" for Panel PCs – Flat Panel SCD1900 portrait • Area of application food and beverages industry and pharmaceuticals: - Panels and Panel PCs with stainless steel front - HMI panels as rear-mounting devices - Flat Panels with stainless steel front - HMI stainless steel operator stations • Area of application oil & gas, chemicals and shipbuilding: - MP 377 15" Touch daylight readable © Siemens AG 2013 Customized Automation Renewable energy Renewable energy ■ Overview SIMATIC HMI products are provided with additional features in order to facilitate use in specific sectors. Photovoltaic systems are subject to hardly any mechanical stress and therefore require little maintenance. This also requires reliable and low-maintenance devices in the automation system. With the wide operating temperature range at a high computing power, with their various mounting styles, as well as options for diagnostics and data backup, SIMATIC Panels and IPCs meet these requirements. Wind farms can be used in all climatic zones and also in poorly accessible areas, e.g. offshore. The requirements regarding the control systems are accordingly diverse, and complete freedom from maintenance of the devices is required. The industrial PCs of the 427 series can meet these requirements. Versions of the Microbox treated by special paint processes can also be used in salt-laden air. 6 Siemens ST 80 / ST PC · 2013 6/27 © Siemens AG 2013 Customized Automation Renewable energy Solar systems ■ Overview ■ Application Solar systems Compared to other power plants, photovoltaic systems are subject to hardly any mechanical stress and therefore require little maintenance. The same also applies for solar and solarthermal systems. This also reduces the maintenance overhead on the devices. The SIMATIC Industrial PCs and Panels meet these requirements through the targeted selection of highquality components and special production processes. ■ Benefits 6 SIMATIC Box PC family with mounting bracket for front mounting in portrait format • • • • • Long service life Extra long spare parts availability Adapted computing power High system availability Individually adaptable 6/28 Siemens ST 80 / ST PC · 2013 All SIMATIC Panels and IPCs are developed for especially demanding environments and also for long service life. Spare parts availability for many years secures use in sound solar and photovoltaic systems. • Rugged: Ambient temperatures of 0 °C to +55 °C offer high flexibility in the choice of installation location. Use of a TEK is recommended for increasing the temperature range (see Chapter: Temperature Extension Kit). • Innovative and flexible: - We meet the ever-increasing demand for more computing power by using the current generation of processors from Intel®. Based on the current chipsets, devices are available with CeleronM, Core2Solo, Core2Duo and Core2Quad. This makes power-saving applications (e.g. simple data acquisition) just as possible as power-hungry applications (such as the software PLC in real-time WinAC RTX) and server systems. - The SIMATIC IPCs fit into any control cabinet. Different mounting methods enable a host of installation variants. Optimized equipping of the Panels and IPCs for more system availability is one of the simplest options for increasing productivity by means of reducing standstill times. Electromechanical components often cause malfunctions in PCs. Since hard disks and fans in the industrial PC usually operate continuously, they are subject to an especially high rate of wear and tear. Software options for diagnostics and data backup, such as SIMATIC IPC DiagMonitor or SIMATIC IPC Image Creator, are particularly effective here, in addition to the use of high-quality industrial grade components. © Siemens AG 2013 Customized Automation Renewable energy Wind farms ■ Overview Wind farms Wind farms can be used to produce electrical power in all climatic zones, at sea, and in all types of terrain. The requirements regarding the control systems for wind turbines and wind parks are as diverse as the installation locations. These locations are increasingly difficult to reach. This means the equipment must be completely maintenance-free. The Industrial PCs of the 427 series can meet these requirements. By selecting high-quality components and special production procedures, all the SIMATIC IPCs and Panels can be used for several years without requiring servicing. ■ Benefits ■ Application All SIMATIC Panels and IPCs are developed for especially demanding environments. The devices are optimally equipped to deal with vibration in wind turbines: rugged enclosures, special hard disk brackets, and interlocks are just a few examples of standard features on SIMATIC devices. • Rugged: - The SIMATIC IPCs fit into any control cabinet. Different mounting methods enable a host of installation variants. Ambient temperatures of 0 °C to +55 °C are supported on the IPC427C, with much higher temperatures in some applications. Use of a TEK is recommended for extreme temperatures (see Chapter: Temperature Extension Kit). - Salt-laden atmospheres are hard on the devices. SIMATIC Panels are also available in the IP65 type and are thus eminently suitable for offshore use. Versions of the Microbox 427C also enable use in salt-laden atmospheres: this is made possible by special paint processes that have been in use for many years. • Innovative and flexible: We meet the ever-increasing demand for more computing power by using the current generation of processors from Intel®. Based on current chipsets, devices with Celeron M, Core2 Solo, Core2 Duo and Core2 Quad are available. This makes power-saving applications (e.g. simple data acquisition) just as possible as power-hungry applications (such as the software PLC in real-time WinAC RTX) and server systems. Optimized equipping of the IPC and the Panel for more system availability is one of the simplest options for increasing productivity by means of reducing standstill times. Electromechanical components often cause malfunctions in PCs. Since hard disks and fans in the industrial PC usually operate continuously, they are subject to an especially high rate of wear and tear. Software options for diagnostics and data backup, such as SIMATIC IPC DiagMonitor or SIMATIC IPC Image Creator, are particularly effective here, in addition to the use of high-quality industrial grade components. 6 SIMATIC IPC427C with expansion frame • • • • • Suitable for special temperature requirements Maintenance-free for offshore use Can handle high mechanical load High system availability Individually adaptable Siemens ST 80 / ST PC · 2013 6/29 © Siemens AG 2013 Customized Automation Automotive industry HMI operator stations for the automobile industry ■ Overview Operations computer: Unit operator panel and protective guard control box (PGCB) • Colors to complement design, also possible in customized RAL colors • Rugged and maintenance-friendly device design • Very high EMC • Distributed configuration for large machines and distributed installations • Optimized high-speed operator control thanks to: - Reduced number of operator controls - Optimum control element layout - 24 V DC hardware - Direct keys or high-speed PROFIBUS communication for direct keys • Use of high-capacity mass storage for large software applications • Silicone-free device configuration • Chemically-resistant surfaces (resistant to lubricants and fillers, oils, etc., in particular) • Welding sputter-resistant surface • Project-specific software ready installed ■ Application In automotive industry, the fault-free operation of production facilities is of paramount importance. The requirements of industrial control enclosures in respect of impermeability to dust and water, as well as those in respect of the management of the internal heat balance are therefore very high. In addition to the HMI IPC477C and HMI IPC577C, the HMI IPC677C and Flat Panels are also suitable for use as operator PCs in the automotive industry. ■ Design The fully-equipped and wired turnkey solutions in a variety of designs are ideal for the requirements of the automotive industry. 6 ■ Benefits • Modern design combined with outstanding functionality • Increased heat dissipation thanks to ribbed aluminum profile and backpanel heat sink • Easy access to controls thanks to hinged front frame or hinged backpanel • Modular system for precise customization and tailoring to Panel or Panel PC • High-quality aluminum press-drawn section with clean surface finish 6/30 Siemens ST 80 / ST PC · 2013 • The modular design with a variety of aluminum frame and expansion profiles can support all required device combinations. A variety of operator stations appear in the overview: - Modular aluminum control enclosure system for the combination of multiple HMI Panels, Panel PCs, and Simatic S7 PLCs - Modular aluminum control enclosure system for the combination of multiple HMI Panels - Modular aluminum control enclosure system for the installation of an HMI Panel or Panel PC (see "Overview" figure bottom left) • Can be accessed via hinged front frame or hinged backpanel • Integrated support arm elements at the top and bottom for the direct attachment of support arm couplings • Integrated handle attachments facilitate handling and underline the design image Certifications/Approvals • IP65 • NEMA 4/EEMAC Type 12 • cULus • CE © Siemens AG 2013 Customized Automation Automotive industry HMI operator stations for the automobile industry ■ Technical specifications Examples from the automotive industry Type HMI operator control unit Operator PC unit operator panel + PLC SIMATIC HMI IPC677C PC Box based on SIMATIC HMI IPC677C • • • • • Core i7, 2.53 GHz, 4 GB RAM • 250 GB HD, • Without MPI/PROFIBUS + 2 x Ethernet interface 10/100 Mbit • Europe default 230 V Components Computing unit Front panel Core i7, 2.53 GHz, 4 GB RAM 250 GB HD, PROFINET + 2 x Ethernet interfaces 10/100 Mbit Europe default 230 V SIMATIC HMI IPC677C 15" Touch, 15" XGA 1024x768 resolution Customized front with 2x6 control keys, 15“ XGA 1024x768 resolution • PP17-I PROFIsafe • PP17-II • S7-400 configuration Additional components Additional components Operator panel enclosure CC-4000, mounted on stand • VIP 6000 (upper part) • IW 6900 (lower part) Dimensions 578 x 764 x 183 mm 630 x 1870 x 636 mm Operator panel with slide-in label – Keyboard Sasse stainless steel keyboard IP65 Sasse stainless steel keyboard IP65 Mouse Track-Ball integrated in the keyboard Optical mouse Elements 3 x 3SB3 elements with labeling plates, 1 x Emergency Off, 1x machine circuit-breaker, signal light processing possible 2 x 4 operator controls, 1 x Emergency Stop Locking • E1-locking for enclosure lock • E7 key-operated switch Customized enclosure lock Mounting Installation in operator panel enclosure with electrical wiring Installation in operator panel enclosure with electrical wiring Ventilation – – Terminals Use of 3-wire terminals Use of Wago terminals Core identification Yes Yes Base profile • Icotec • RJ45 Ethernet port • Icotec • RJ45 Ethernet port Software: • Windows 7, MUI • WinCC V7.x • SIMATIC STEP 7 Prof V5.x • • • • • • Type Protective guard control box (PGCB) Components • SIMATIC HMI KP8F • SIMATIC ET200S • SCALANCE X202 – 2P IRT Ethernet switch Additional components Operator panel enclosure AE housing Dimensions 300 x 300 x 155 mm Elements • • • • Locking Customized enclosure lock Mounting Installation in operator panel enclosure with electrical wiring Core identification Yes 8 short-stroke keys 1 x emergency stop 3 x Siemens key switches 1 x signaling column Windows 7, MUI SIMATIC Softnet S7 for IE V 6.x SIMATIC STEP 7 V 5.x SIMATIC S7-Graph V 5.x SIMATIC DistributedSafety V 5.x InTouch Runtime V 9.x 6 ■ More information Quotation preparation Product specification according to customer requirements. Quotation preparation by SIMATIC HMI specialists, specification of: • Non-recurring costs • Prototype costs • Standard unit prices • General conditions (product agreement) There is a minimum annual quantity/purchase quantity (minimum quantity per type: 20), which is agreed with the customer for the project. Customized products can only be ordered in conjunction with a product agreement. A customer-specific order number is allocated during the product agreement process. SIMATIC contacts in your area http://www.siemens.com/automation/partners Siemens ST 80 / ST PC · 2013 6/31 © Siemens AG 2013 Customized Automation Automotive industry Front panel 15" with motion keys at side ■ Overview ■ Design • 2 x 6 function keys (24 V DC) on left and right of display • Function keys connectable using non-interchangeable terminals, e.g. using vacant inputs of a Push Button Panel to the control • Display surface resistant to welding beads • USB interface at the front • External dimensions and mounting cutout as for corresponding standard product • IP65 degree of protection at the front ■ Technical specifications Front panel 15" with function keys at side for Panel PC in the automotive industry The front panel 15.1" with arrow keys at side is designed as a front unit for Panel PC. The arrow keys at the side allow intuitive and direct activation of movements in the plant. The display is a pure display unit, alphanumeric characters are entered using an external keyboard and external pointing device. ■ Benefits • Display unit with additional function keys for efficient and direct activation of motions • Display surface resistant to welding beads • 24 V DC function keys for wiring to digital inputs of controller • Non-interchangeable terminals ■ Application Type Front panel 15" with lateral function keys Display 15.1" TFT Resolution (pixels) 1024 x 768 pixels General features As for 15.1" front panel for HMI IPC677C Special features Interfaces USB interface at the front Connectable to Panel PC HMI IPC477C, HMI IPC677C, compact and distributed design Number of keys 2 x 6 function keys (24 V DC) on left and right of display, wired to terminals Modification possibilities • Customized design • Modification of front design ■ More information Quotation preparation Product specification according to customer requirements. Quotation preparation by SIMATIC HMI specialists, specification of: • Non-recurring costs • Prototype costs • Standard unit prices • General conditions (product agreement) 6 There is a minimum annual quantity/purchase quantity (minimum quantity per type: 20), which is agreed with the customer for the project. Customized products can only be ordered in conjunction with a product agreement. A customer-specific order number is allocated during the product agreement process. SIMATIC contacts in your area http://www.siemens.com/automation/partners Application example: Operations computer in the automotive industry The front panel for Panel PCs with function keys at the side is designed for HMI operations in the automotive industry, e.g. as a display for control computers. The front unit as the display unit with function keys at the side is always used if comprehensive inputs are necessary using an external keyboard and pointing device, but where efficient control of movements should be additionally possible using the function keys assigned to the graphics and directly to the PLC. 6/32 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Customized Automation Automotive industry Mobile Panel 277 10" Remote Operate ■ Overview Front view ■ Design Rear view • For high-contrast and clearly readable display of already configured SIMATIC WinCC process pictures of a stationary operator panel (e.g. with PC 677) without further configuring and adaptation overhead • Server and client optimized for the following resolutions: - Remote Operate Server with 1024 x 768 pixels - Remote Operate Client with 800 x 600 pixels. • Features - High-resolution display 10" SVGA - Integral acknowledgment and stop button (safety category 3 in accordance with EN 954-1) - Rugged and double-panel enclosure (drop height 1 m, complete IP65 degree of protection) - Thin Client concept: Communication with the higher-level operator station using Remote Operate software and PROFINET ■ Application Side view User-friendliness and ergonomic use were consistent design considerations. With its low weight and compact design, the Mobile Panel sits comfortably in the hand. The Mobile Panels are extremely impact-resistant thanks to the double-panel design and the rounded enclosure shape. The STOP button is protected by a "collar" against unintentional use and against damage when dropped. Harsh industrial environments present no problems to the SIMATIC Mobile Panels with their dust and spray-water-protected enclosures in degree of protection IP65. The Mobile Panel is simply connected wherever it is needed in the plant. The rugged connection box with degree of protection IP65 can be installed anywhere. It ensures fault-free connection and disconnection during normal operation and thus enables the operator-control locations to be easily and safely changed when several connection points are available in a plant. RO Client 800 x 600 pixels and RO Server 1024 x 768 pixels The SIMATIC Mobile Panel 277 10" Remote Operate (RO) from Siemens bridges the gap between flexible use through portability and ease of handling, and the benefits of a thin client concept. The cable is up to 25 meters in length and handles power supply, transfer of the STOP and acknowledgment button signals, and also data communication. The device has no rotating media. Existing WinCC configurations of a Panel PC 677 15" can be represented with functional compatibility. Reliable data transfer and short response times are guaranteed here. Operator input using the touch screen is intuitive. The optional device holder enables secure storage or stationary operation of the Mobile Panel. Siemens ST 80 / ST PC · 2013 6/33 6 © Siemens AG 2013 Customized Automation Automotive industry Mobile Panel 277 10" Remote Operate ■ Mode of operation All applications are run on the the Remote Operate Server, which in turn handles any control connection to the production process. The user now decides which applications will be operated and monitored from the Mobile Panel. The plant operator hardly notices that he or she is now working on the main operator station and no longer locally. ■ Technical specifications Type Mobile Panel 277 10" Remote Operate Display 10" touch screen SVGA with 800x600 pixels, TFT display with 65,536 colors Operation Touch screen with captive stylus and stylus holder, three-level acknowledgment button (deadman's switch) integrated into the handle, stop button, function keys, key-operated switches and backlit pushbuttons as option. Suitable for left and right-handed operation Interfaces Hardwired connection line to connection box Plus for PROFINET/ Ethernet and power supply (e.g. Mobile Panel 277 PN) Software Remote Operate Client software (Thin Client) on Windows CE 5.0, function-compatible representation of existing WinCC configurations/ software applications of an existing server, e.g. PC677 Ambient conditions Full IP65 degree of protection, ambient operating temperature 0°C to 40°C, drop height to 1.0 m Certification CE, cULus, C-Tick, EMC compliance, prototype test (BG/BIA or SIBE Switzerland) In the accessories pack CD-ROM, operating instructions, programming manual for Remote Operate Software Options Membrane function keys, access control (key-operated switch), buttons, handwheel Weight 2.3 kg The device does not process the data locally, but instead accesses the data of up to ten selectable main operator stations with the help of the pre-installed Remote Operate Client software. These main operator stations are, in turn, equipped with the Remote Operate Server software. All stations are connected via Industrial Ethernet. The Mobile Panel is thus optimized exclusively on the visualization and management of the different stationary operator stations. Communication with the higher-level operator station takes place via the Remote Operate software and is enabled via PROFINET. ■ Function • Automatic restart after switching on and display of the server selection list (up to 4 hierarchical levels and up to 10 servers) • Password protection • Automatic Reconnect of client • Operation authorization indication (traffic light) on the server and client Sophisticated safety concept The Mobile Panel has an acknowledgement button (in accordance with EN 60204-1) with three switching steps. This can be adjusted to an ergonomic position for both left-handed users and right-handed users simply by turning. The STOP pushbutton (acc. to EN 60204-1) can be looped into the EMERGENCY OFF circuit of a machine and positively latches when pressed. It is distinguished from an EMERGENCYOFF button by its gray color. This ensures that it cannot be mistaken for the EMERGENCY-OFF equipment. 6 The STOP and acknowledgment buttons are implemented as double circuits in accordance with Safety Category 3 to EN 954-1. 6/34 Siemens ST 80 / ST PC · 2013 Type PN Plus connection box Interfaces 2 x Ethernet with 10/100 Mbit/s, integrated switch Expansion for operator-process communication Reconnection during operation without interrupting the emergency stop circuit, monitoring of the STOP button, location recognition (through hardware) ■ Ordering data Order No. Mobile Panel 277 10" Remote Operate Configuration on request 6AV6645-7AB10-0AS0 Connection box PN Plus 6AV6671-5AE11-0AX0 Connecting cable •5m • 10 m • 25 m 6XV1440-4BH50 6XV1440-4BN10 6XV1440-4BN25 © Siemens AG 2013 Customized Automation Automotive industry Mobile Panel 277 10" Remote Operate ■ More information Customer-specific modifications • Individual company logo instead of the Siemens logo and changing the type designation • Changing the keyboard colors, labeling, symbols and background color • Possible options: Membrane function keys, access control, pushbuttons and handwheel Quotation preparation SIMATIC HMI specialists define the product modifications precisely in accordance with customer requirements. This is followed by drafting of a quote by SIMATIC HMI specialists, determining the following: • Non-recurring costs • Prototype costs • Standard unit prices • and the marginal conditions in the form of a product agreement (e.g. minimum quantity). The defined device can be easily ordered using this product agreement and a customized order number. Device fronts are to be stored and provided by the customer upon delivery completion. 6 Siemens ST 80 / ST PC · 2013 6/35 © Siemens AG 2013 Customized Automation General machine construction Front panel 15" Touch and Key for Panel PCs, resistant to honing oil ■ Overview ■ Benefits • • • • • Combined Touch + Key operation for increased inefficiency Touch pen operation avoids contamination of the display area Ergonomically shaped touch pen which cannot be lost Simple cleaning Resistant to coolants and lubricants ■ Application The front panel for Panel PCs with touch screen and membrane keyboard has been designed for operator control and monitoring at machine level for machine construction applications, where honing oil and lubricants are used. The touch and key front is always used if efficient operation of the machine is associated with the following requirements: • Intuitive operation using graphic representation on display • Specific command inputs using fixed command inputs • Effective inputs in forms using the integrated numeric and alphanumeric keyboard Also in applications with increased environmental influences such as dirt and oil. The homogenous foil surface without joints or edges permits easy cleaning, and is resistant to coolants and lubricants. Application examples • Printing machines • Drilling, milling, honing machines • Brake test stands • Injection molding machines • Building management • Warehouse systems • Automotive industry ■ Design The Front Panel Touch and Key is designed as a front unit for Panel PCs. The combination of Touch and Key operation as well as the resistance to honing oil are characteristics of this product. 6 Complete lamination of the decoration foil over the touch area of the display increases the resistance against contamination and welding beads, and the absence of edges and joints facilitates cleaning. Openings and cutouts in the front have been completely omitted in favor of a homogenous surface which can also be used in the environment of honing oil and similar cooling agents and lubricants. Clear operation is achieved using the Touch pen which is delivered as standard and can be stored in a front holder. Dirty or oily hands are therefore not an argument against using a Touch screen. The pen has an ergonomic shape, is optimized for operations when wearing gloves, and is linked to the front using an elastic helix cable. Its "parking position" in the special stainless steel holder on the front means that it is always readily accessible. 6/36 Siemens ST 80 / ST PC · 2013 • External dimensions and mounting cutout as for corresponding standard product • Degree of protection IP65 at the front © Siemens AG 2013 Customized Automation General machine construction Front panel 15" Touch and Key for Panel PCs, resistant to honing oil ■ Technical specifications ■ More information Type Front panel 15" Touch + Key, resistant to honing oil Display 15.1" TFT Touch Resolution (pixels) 1024 x 768 pixels General features As front panel 15.1" Touch for Panel PC 677 Special features Interfaces Without front-sided USB interface Connectable to Panel PC PC 477, PC 677 compact and distributed design Number of keys 58 system keys and alphanumeric keys 20 function keys with LED Resistance Tested with: Castrol Honilo 981 honing oil Quotation preparation Product specification according to customer requirements. Quotation preparation by SIMATIC HMI specialists, specification of: • Non-recurring costs • Prototype costs • Standard unit prices • General conditions (product agreement) There is a minimum annual quantity/purchase quantity (minimum quantity per type: 20), which is agreed with the customer for the project. Customized products can only be ordered in conjunction with a product agreement. A customer-specific Order No. is allocated during the product agreement process. http://www.siemens.com/automation/partners 6 Siemens ST 80 / ST PC · 2013 6/37 © Siemens AG 2013 Customized Automation General machine construction Flat Panels, 10.4" for Panel PC ■ Overview ■ Technical specifications • Ideal for machine-level human machine interfacing • Especially suitable for use in machines with restricted installation space • Can be modified in design and front mechanical components (e.g. stainless steel front for food and beverages industry) • Distance between the Flat Panel and PC max. 30 m • Functions correspond to the standard Flat Panels • Available with and without touch operation • VGA and SVGA resolution ■ Application The Flat Panel 10.4" TFT Touch has been designed as display and operator control unit for industrial PCs (e.g. SIMATIC Microbox 427C) and Panel PCs (e.g. PC 677C) and can be separated from the computing unit by up to 30 m. They supplement the SIMATIC standard products and are suitable for machine-level human machine interfacing when PC functionality is required but little space is available for installing a display. VGA and SVGA resolution also in a secondary display, e.g. Panel PC 677C. Flat Panel 10.4” Resolution (pixels) 800 x 600 pixels Input unit Analog-resistive touch screen MTBF (at 25 °C) 50 000 h Power supply 24 V DC, RoHS Front dimensions (L x W x D in mm) 335 x 275 x 75 Installation dimensions (L x W in mm) 310 x 248 Certified in accordance with Can be connected to Approx. weight in kg 0.80 ■ Ordering data Flat Panel 10" Touch Order No. 6AV7461-7TA00-0AA1 SIMATIC Flat Panel 10.4" TFT with analog-resistive Touch Panel, resolution 800 x 600 pixels, 24 V DC power supply, VGA, DVI-D interface, incl. VGA cable 1.8 m ■ More information Customized modification options • Customized design • Modification of front design, e.g. stainless steel front 6 6/38 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Customized Automation Food and beverages industry/pharmaceuticals Introduction ■ Overview Hygiene areas in food and beverage production, pharmaceuticals or fine chemicals all share one requirement: The devices and equipment must be easy to clean. The relevant directives, standards and legislative requirements must be observed, e.g. EHEDG, FDA, DIN EN 1672-2 (Hygienic Design), GMP, LMHV, LMBG. However, optimization and variation in the device hardware are also perfectly possible: • Degree of protection • Ruggedness • Temperature resistance • Design and installation versions • Suitable for clean rooms • Certification in accordance with ATEX The aim is to find the cost-optimized solution for the specific application case. The overview below shows different features depending on the applications areas, from packaging to the wet area in processing. Applications Features Hygienic packaging Pharmaceuticals, fine chemicals Food and beverages, bottle cleaning, bottle filling, laboratories Abattoirs, meat processing Stainless steel front partially x x x Stainless steel control boxes x x x x Stainless steel fully enclosed x x x x Simple to clean x x x x No grooves and gaps, no projections partially partially membrane-covered protective edge not always accepted - Increased tightness - - x x Mechanical ruggedness, no membrane front - - partially x Suitable for high-pressure cleaning (IP69K) - - - partially ATEX Ex Zone 2/22 x x partially - The product examples described on the following pages cover a wide range of the most important requirements. 6 ■ Benefits • Simpler cleaning thanks to resistant and rugged stainless steel front with smooth surface, and minimal grooves and gaps • High degree of protection IP66K (TP 177B and MP 277 additionally IP66K) on the front for increased sealing properties and ruggedness • Food-standard sealing material and shatter protection for the display to prevent contamination of the foodstuffs • Optimized frame design almost flush with the control cabinet so that liquids can run off • Device front developed on the basis of DIN EN 1672-2 • Decorative membrane tested against chemicals in accordance with DIN 42115, Part 21) • Food-standard flat seal in accordance with FDA 21 CFR 177.2006 • Rear tensioning frame (included in scope of supply) for even application pressure of the seal • External dimensions and mounting cutout as for corresponding standard product 1) High degree of protection for humid environments With low installation depth and rugged front, the SIMATIC HMI Standard Panels are eminently suitable for industrial and machine-level use. The Panels with stainless steel front are also even better equipped to meet the high requirements presented by the food and beverage production environment. IP66K degree of protection protects against water even with a jet strength of 100 l/min at 10 bar from a distance of 2.5 m to 3 m. The optimized frame profile and almost flush-mounting of the device on the control cabinet allow liquids to run off. Installation of the operator panels in a stainless steel control cabinet as ready-to-use units is optionally available as a customized version. Special resistance requirements must be examined separately. Siemens ST 80 / ST PC · 2013 6/39 © Siemens AG 2013 Customized Automation Food and beverages industry/pharmaceuticals Introduction ■ Benefits (continued) Certificates, listings and appraisals SIMATIC HMI products with stainless steel front, and the stainless steel operator panel, were subjected to some or all of the tests below and are listed or appraised in accordance with: • High degree or protection IP66K, NEMA Type 4, 4x, 12 • CE-compliant, cULus-listed • LGA mark "Hygiene tested" (Approval document No. 5664018) • Expert appraisal of the Munich University of Technology, Research Center Weihenstephan, in accordance with EHEDG recommendation (Report No.126/01.03.2007) • Clean room qualification by IPA Fraunhofer Institute (test report: Examination of the clean room suitability and ESD characteristics of Panel PCs from Siemens AG, Report No. SI 0810-450 of October 2008) Qualification for clean rooms High-quality products such as semiconductors, medicines, food & beverages, and nanotechnology products are subject to special demands with regard to contamination with particles or bacteria. Increased requirements for protection of the products and processes can only be met by production in clean rooms with suitable equipment under controlled conditions. Clean rooms are classified according to particle quantities and sizes per m3 of room air and time unit. Clean room classes in accordance with ISO 14644-1 (ISO 1 to 9) have been introduced in pharmaceuticals, for example, in accordance with EG-GMP, Annex 1 (Classes A to F), and in semiconductor production. 6 Example: A person in normal clothing emits approximately 80,000 particles >= 0.5 mm per second (in clean room clothing, this can be reduced to approximately 700 particles/s >= 0.5 mm). • Requirements regarding equipment in clean rooms include the following: • Surfaces that are easy to clean and disinfect • As few adhesives as possible, e.g. electrostatic • No emitting surfaces • Shape favorable to air circulation, no air eddies • Dense, as few hollow or dead spaces as possible • Smooth, as few grooves and gaps as possible The SIMATIC HMI products with stainless steel front and the stainless steel operator panel have been designed for these requirements. The stainless steel operator stations with Panel PC 677B 15" Touch INOX and MP 377 15" Touch INOX have been tested by the Fraunhofer Institute and qualified for "obvious suitability for clean rooms of ISO Class 1 in accordance with DIN EN ISO 14644-1". 6/40 Siemens ST 80 / ST PC · 2013 ■ Application Quality and hygiene are decisive competitive features in the production of food and beverages. In addition, higher volumes have to be produced in shorter times and with rising quality demands. Objects and equipment that come into contact with food and beverages must be • such that they are clean and can be maintained and, if necessary, disinfected, and have no adverse effect on the food and beverages • installed in such a way that the immediate environment can be cleaned appropriately. Objects and equipment must be clean and well maintained (extract from the German food and beverages hygiene legislation). This requires not only the innovative know-how of engineering offices, mechanical equipment manufacturers and plant builders, but also modern, powerful human machine interface systems whose hardware and software are adapted to the special requirements. The SIMATIC Panels and Panel PCs with touch screens and stainless steel fronts have been designed for use in the food, beverages and tobacco industry and for operator control and monitoring close to food processing machines. For this reason, the devices with stainless steel front have been developed in compliance with DIN EN 1672-2 "Food processing machinery – Safety and Hygiene Requirements". Simpler cleaning and disinfecting The high quality requirements in the food and beverages industry require a high standard of the food processing machinery. There are many relevant regulations, directives, ordinances, standards and laws. Essential here is that all equipment and components must be easy to clean and disinfect so that cross-contamination of the foodstuffs can be avoided. The Panels with stainless steel front have a 240 grit hairline finish, so they are suitably smooth. The membrane covering the display cutout is tested with regard to its resistance to chemicals, has minimal grooves and gaps in which microorganisms could settle, and also provides shatter protection for the display. © Siemens AG 2013 Customized Automation Food and beverages industry/pharmaceuticals Panels and Panel PCs with stainless steel front ■ Overview TP 177B color PN/DP, MP 277 10" Touch, MP 377 15" Touch and Panel PC 677B 15" The SIMATIC Panels with touch screens and stainless steel fronts have been designed for use in the food, beverages and tobacco industry for operator control and monitoring close to food processing machines. They have been developed in compliance with DIN EN 1672-2 "Food processing machines – Safety and Hygiene Requirements". • Simple cleaning and disinfecting - Stainless steel surface with 240 grade hairline finish - Membrane tested for resistance to chemicals - Minimal number of grooves and joints - Optimized frame profile so that liquids can run off • Display shattering protection • Degree of protection IP66K ■ Design • External dimensions and mounting cutout as for corresponding standard product • Optimized frame profile with a slight projection to the cabinet • IP66K degree of protection at the front • Surface ground with 240 grain abrasive • Minimal number of grooves and joints • • • • Decorative film tested for resistance to chemicals Display splash protection Food-standard seals Rear tensioning frame for even application pressure of the seal ■ Technical specifications Multi Panels MP 277 10" Touch INOX MP 377 15" Touch INOX Power supply 24 V DC 24 V DC Display 10.4" color TFT Touch 15.1" TFT Touch Resolution (pixels) 640 x 480 1024 x 768 MTBF of backlighting (at 25 °C) about 50 000 hours LED backlighting about 50 000 hours CCFL backlighting General features Front Material Stainless steel 1.4301, polyester-based membrane Surface Hairline finish, 240 grit abrasive grain Device seal EPDM flat seal 6 Special features Ambient conditions Degree of protection on the front: IP66K, NEMA 4, 4x and 12; on the rear: IP20 Ambient temperature during operation 0 ... 50 °C Relative humidity max. 85% (no condensation) Transport/storage temperature -20 °C to +60 °C Approvals FM Class 1 Div 2, cULus, CE, C-Tick, ATEX Zone 2/22 Sector Food & beverages, pharmaceuticals Food & beverages, pharmaceuticals WinCC flexible 2005 Standard and higher WinCC flexible 2007 Standard and higher External dimensions (W x H x D in mm) 325 x 263 400 x 310 Installation cutout (W x H x D in mm) 310 x 248 368 x 290 Special features Clamping frame Clamping frame Weight Approx. 4.2 kg Approx. 6.2 kg HMI software (to be obtained separately) HMI engineering software Dimensions Siemens ST 80 / ST PC · 2013 6/41 © Siemens AG 2013 Customized Automation Food and beverages industry/pharmaceuticals Panels and Panel PCs with stainless steel front ■ Technical specifications (continued) Panel PC Panels Panel PC 677B 15" Touch INOX TP 177B PN/DP INOX Power supply 100/230 V AC (autorange), 50/60 Hz or 24 V DC 24 V DC Display 15.1" TFT Touch 5.7" color STN Touch (256 colors) Resolution (pixels) 1024 x 768 320 x 240 MTBF of backlighting (at 25 °C) about 50,000 hours CCFL backlighting Special features Without front USB interface General features 1 x emergency-off, 3 x short-stroke membrane keys with LED on front, wired to terminal Front Material Stainless steel 1.4301, polyester-based membrane Surface Hairline finish, 240 grit abrasive grain Device seal EPDM flat seal Special features on the front: IP66K, NEMA 4, 4x and 12; on the rear: IP20 Decorative membrane drawn across the display Degree of protection on the front: IP66K, NEMA 4, 4x and 12; on the rear: IP20 on the front: IP66K, NEMA 4, 4x and 12; on the rear: IP20 Ambient temperature during operation 0 ... 50 °C 0 ... 50 °C Relative humidity max. 85% (no condensation) Transport/storage temperature -20 °C to +60 °C Approvals CE, cULus FM Class 1 Div 2, cULus, CE, C-Tick, ATEX Zone 2/22 Sector Food & beverages, pharmaceuticals Food & beverages, pharmaceuticals HMI engineering software WinCC flexible Advanced and higher WinCC flexible 2005 Compact and higher HMI Runtime software WinCC flexible RT Ambient conditions HMI software (to be obtained separately) Dimensions External dimensions (W x H x D in mm) 483 x 310 212 x 156 Installation cutout (W x H x D in mm) 450 x 296 198 x 142 Special features Clamping frame Clamping frame Can be connected to SIMATIC PC On Panel PCs as well as other SIMATIC Rack and Box PCs Weight Approx. 15 kg 6 6/42 Siemens ST 80 / ST PC · 2013 Approx. 1.5 kg © Siemens AG 2013 Customized Automation Food and beverages industry/pharmaceuticals Panels and Panel PCs with stainless steel front ■ Ordering data TP 177B color PN/DP INOX Order No. 6AV6642-8BA10-0AA0 with stainless steel front, otherwise corresponding to 6AV6642-0BA01-1AX0 MP 277 10" Touch INOX 6AV6643-0ED01-2AX0 with stainless steel front and LED backlight, otherwise corresponding to 6AV6643-0CD01-1AX1 MP 377 15" Touch 6AV6644-0CB01-2AX0 with stainless steel front and LED backlight; otherwise corresponding to 6AV6644-0AB01-2AX0 Panel PC 677B 15" with stainless steel front, otherwise corresponding to Panel PC 677B Configurator 6AV6643-0CD01-1AX1 6AV7872-2… ■ More information Customized modification options • Customized design - Use of the company name instead of the Siemens logo and modification of the type designation - Changing the background color • Customer-specific hardware modifications such as the design and dimensions of the front plate, selection of the display, memory capacity, drives, options • Customer-specific Panel PC configuration as a rugged embedded hardware and software system, without hard disk and with tailor-made software • Customer-specific software suite with choice of Windows operating systems • Customer-specific Panel PCs with software suite with choice of Windows operating systems • Protection against condensation and corrosive gases (for selected panels) • Device mounted in a stainless steel cabinet as a ready-toinstall and ready-to-connect terminal which is ergonomic, functional, with high degree of protection as well as tested heat dissipation (e.g. with complete degree of protection IP66K) Drafting a quotation SIMATIC HMI specialists define the product modifications precisely in accordance with customer requirements. This is followed by drafting a quotation with: • Non-recurring costs • Prototype costs • Standard unit prices • and the marginal conditions in the form of a product agreement (e.g. minimum quantity). The defined device can then be easily ordered using this product agreement and a customized Order No. 6 Siemens ST 80 / ST PC · 2013 6/43 © Siemens AG 2013 Customized Automation Food and beverages industry/pharmaceuticals HMI Panels as rear-mounted devices ■ Overview ■ Design MP 377 12" Touch, rear-mounting The front frame is modified customer-specifically on the "rear-mounting devices": The surface with the display viewing area covered with decorative membrane, and the marginal area around the display necessary for touch operation must be flush with the control cabinet sheet metal at the front. For this purpose, the front frame with the device seal and the cutouts for the holding bolts are set back from the visible surface by the thickness of the control cabinet sheet metal. The enclosure must have a suitable number of stud bolts available. The all-round device seal thus enables a high degree of protection: IP65. The installation cutout can be dimensioned in such a way that the rear-mounting device can be replaced with the same type of front-mounting device for service purposes. MP 277 8" Touch vertical, rear-mounting MP 377 12" Touch, rear-mounting, MP 277 8" Touch vertical, rear-mounting 6 The solution for installing HMI devices without "corners and edges" on the front. The devices are installed in the control cabinet enclosure from the rear and are flush with the control cabinet sheet metal at the front. They are therefore known as "rear-mounting devices". ■ Benefits • • • • Front surface flush with the control box Simple to clean No dirt-collecting edges and deposits Front membrane resistant to the usual cleaning agents and disinfectants • Can be replaced with front-mounting device of the same type for service purposes (MP 377 12" Touch rear-mounting only) 6/44 Siemens ST 80 / ST PC · 2013 The decorative membrane is also drawn across the visible area of the display on the rear-mounting devices, so there is no cutout with adhesive edge above the display. The decorative membrane is smooth. For sensitive applications where the gap dimension of the control cabinet cutout has too great a tolerance, there is the option of covering the entire surface including the gap with a transparent and replaceable membrane. © Siemens AG 2013 Customized Automation Food and beverages industry/pharmaceuticals HMI Panels as rear-mounted devices ■ Technical specifications MP 277 8" Touch vertical, rear-mounting MP 377 12" Touch, rear-mounting Power supply 24 V DC 24 V DC Display 7.5" TFT Touch 12.1" TFT Touch Resolution (pixels) 480 x 640 (portrait) 800 x 600 MTBF of backlighting (at 25 °C) about 50,000 hours CCFL backlighting Special features 1 x emergency-off, 3 x short-stroke membrane keys with LED on front, wired to terminal General features Front Material Aluminum under polyester-based membrane Surface Hairline finish, 240 grit abrasive grain Device seal On the enclosure, customized Special features Decorative membrane drawn across display On the front Ambient conditions Degree of protection IP65 at front; IP20 at rear Ambient temperature during operation 0 ... 50 °C Relative humidity max. 85% (no condensation) Transport/storage temperature -20 °C to +60 °C Approvals CE Sector Food & beverages, packaging systems, pharmaceuticals CE, cULus HMI software (to be obtained separately) HMI engineering software From WinCC flexible 2007 Standard with add-on for portrait format WinCC flexible 2007 Standard and higher External dimensions (W x H x D in mm) 229 x 318 As installation cut-out Installation cutout (W x H x D in mm) 233 x 322 x 67 Compatible with standard device Special features Rear-mounting panel in portrait format Rear-mounting panel; panel cutout as on standard device Weight Approx. 2.7 kg Approx. 5.5 kg Dimensions ■ Ordering data MP 377 12" Touch, rear-mounting Order No. 6AV6644-… Configuration on request MP 277 8" Touch vertical, rear-mounting With emergency-off button and 3 short-stroke keys with LEDs on the front Configuration on request 6AV6643-… ■ More information Customized modification options Customized rear-mounting versions can also be implemented: • Customized operator controls possible on the front, e.g. membrane keys, emergency-off • Adaptation to the design of the customized enclosure • Customized design (logo and color scheme) on the front membrane • Portrait mode of the display • Increased resistance to shock and machine vibration Quotation preparation SIMATIC HMI specialists define the product modifications precisely in accordance with customer requirements. This is followed by drafting of a quote with: • Non-recurring costs • Prototype costs • Standard unit prices • and the marginal conditions in the form of a product agreement (e.g. minimum quantity). The defined device can then be easily ordered using this product agreement and a customized order number. Siemens ST 80 / ST PC · 2013 6/45 6 © Siemens AG 2013 Customized Automation Food and beverages industry/pharmaceuticals Flat Panels with stainless steel front ■ Overview ■ Design • Functions compatible with the SIMATIC HMI Standard Flat Panels • Enclosure seal EPDM, sulfur-free • Decorative membrane laminated over display, no display cutout • 240 grain brushed stainless steel surface The Flat Panels 15" Touch INOX and 19" Touch INOX VESA are fully enclosed and are suitable for space-saving mounting on a support system. The cables are then run in the supporting tube. Flat Panel 15" Touch INOX, Flat Panel 15" Touch INOX (enclosed), Flat Panel 19" Touch INOX, Flat Panel 19" Touch INOX (enclosed) The Flat Panels with touch screen and stainless steel front are designed as a display and operating unit for SIMATIC PCs in the food and beverages industry, pharmaceuticals and related industries. They are easy to clean and can be installed in production areas subjected to splashes in a suitable control cabinet. 6 6/46 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Customized Automation Food and beverages industry/pharmaceuticals Flat Panels with stainless steel front ■ Technical specifications Flat Panel 15" Touch, INOX 15" Touch INOX fully enclosed 19" Touch, INOX 19" Touch INOX fully enclosed General features Power supply 24 V DC 24 V DC 24 V DC 24 V DC Display 15.1" TFT Touch 15.1" TFT Touch 19.1" TFT Touch 19.1" TFT Touch Resolution (pixels) 1024 x 768 1024 x 768 1280 x 1024 1280 x 1024 MTBF of backlighting (at 25 °C) approx. 50 000 hours CCFL backlighting Special features Without front USB interface Without front USB interface OSD operation not accessible; values preset EPDM flat seal EPDM flat seal OSD operation not accessible; values preset Front Material Stainless steel 1.4301, polyester-based membrane Surface Hairline finish, 240 grit abrasive grain Device seal EPDM flat seal Special features Decorative membrane drawn across display Ambient conditions Degree of protection On the front: IP66K, NEMA 4, 4x and 12; on rear: IP20 Complete IP65, NEMA 4 On the front: IP66K, NEMA 4, 4x and 12; on rear: IP20 Complete IP66K, NEMA 4, 4x and NEMA 12 Ambient temperature during operation 0 ... 50 °C 0 ... +40 °C at an angle of up to +/- 20° from the vertical 0 ... 50 °C 0 ... +40 °C Relative humidity Max. 85% (no condensation) Transport/storage temperature -20 °C to +60 °C Approvals CE, cULus CE, cULus CE, cULus CE, cULus Sector Food & beverages, pharmaceuticals Pharmaceuticals Food & beverages, pharmaceuticals Food & beverages, pharmaceuticals External dimensions (W x H x D in mm) 483 x 310 383 x 324 x 72 483 x 400 483 x 399 x 61 Installation cutout (W x H x D in mm) 450 x 296 Special features Clamping frame Tiltable customized flange for mounting on control cabinet, sealed by bellows Clamping frame fully enclosed, VESA 100 Weight Approx. 7 kg Approx. 12 kg Approx. 10 kg Approx. 12 kg Dimensions ■ Ordering data Order No. Flat Panel 15" Touch INOX 6AV7486-2TA10-1AA0 Flat Panel 15" Touch INOX fully enclosed 6AV7476-... Configuration on request Flat Panel 19" Touch INOX 6AV7486-4TA01-0AA0 Cable 1.8 m pre-assembled ■ More information 6 Customized modification options • Customized design • Customized flange connection • Cable length up to 30 m Drafting a quotation Cable 1.8 m enclosed Flat Panel 19" Touch INOX fully enclosed 450 x 380 6AV7486-4TA11-0AA0 SIMATIC HMI specialists define the product modifications precisely in accordance with customer requirements. This is followed by drafting a quotation with: • Non-recurring costs • Prototype costs • Standard unit prices • and the marginal conditions in the form of a product agreement (e.g. minimum quantity). The defined device can then be easily ordered using this product agreement and a customized order number. Siemens ST 80 / ST PC · 2013 6/47 © Siemens AG 2013 Customized Automation Food and beverages industry/pharmaceuticals HMI stainless steel operator stations ■ Overview ■ More information Customized modification options • Other HMI devices, display sizes and resolutions • External stainless steel keyboard, e.g. without short-stroke keys with piezo technology • Modification of the front/enclosure design (hygiene test optional) and cable routing • Specific flange from enclosure manufacturers • Breather gland • Use in extended ambient temperature range, e.g. -20 °C to +60 °C - Air-water heat exchanger (internal) - "Temperature Extension Kit" plus active heating and cooling elements SIMATIC HMI Panels or Panel PCs mounted in a stainless steel cabinet as a ready-to-install and ready-to-use terminal that is ergonomic and functional, and has a high degree of protection (complete degree of protection IP66K) as well as tested heat balance. The populated and wired turnkey solutions are based on the hygienic design requirements of the food and beverages industry as well as other hygiene and wet areas, pharmaceuticals, fine chemicals and semiconductor production. ■ Design • Control box completely assembled, wired, tested, with passive cooling Design of stainless steel terminal • For Panels and Panel PCs • Angular surfaces so that liquids can run off • Prepared for stand mounting • With integrated handles at sides. 6 High complete degree of protection • Screwed-on rear panel • Cable inlet through stand and flange Simple to clean • No sharp corners or edges • No dead spaces • Hairline finish of surface with 240 grade grain 6/48 Siemens ST 80 / ST PC · 2013 Certification/approvals • LGA Certificate "Hygiene-tested" • Inspection certificate of the Munich University of Technology • IPA Fraunhofer Institute These modifications are defined by HMI specialists in consultation with the customer who then receives a specific offer. A product agreement with minimum quantities is required for the implementation of customized modifications. Please contact your local/national Siemens HMI representative. © Siemens AG 2013 Customized Automation Oil & gas/chemicals/shipbuilding Oil & gas/chemicals/shipbuilding ■ Overview The requirements of the sectors oil and gas, chemicals and shipbuilding are diverse and range from use in areas subject to explosion hazard involving drill pipes, use in the extended temperature range (outdoor) and in direct sunlight, all the way to use on the darkened bridge of a ship. The following features are required in shipbuilding: • Dimmable display down to complete black-out • Marine Type certification such as Germanischer Lloyd and others In the case of drill pipes in the oil and gas industry and also in the chemicals industry, the following product features are important: • Certification for areas subject to explosion hazard in Zones 2 and 22 in accordance with ATEX, FM Class I, Div. 2 and UL Haz. Loc. • Daylight-readable display • Use in sub-zero temperatures and in regions with high atmospheric humidity • Resistant to harsh environmental conditions • Stainless steel surfaces are demanded for increased resistance to chemicals HMI sector products • MP 377 15" Touch daylight readable 6 Siemens ST 80 / ST PC · 2013 6/49 © Siemens AG 2013 Customized Automation Oil & gas/chemicals/shipbuilding MP 377 15" Touch daylight readable ■ Overview 6 ■ Design • Ideal for use in the oil & gas industry: - Certification in accordance with ATEX for Zone 2/22, UL Haz. Loc., - FM Class I, Div.2 - Bright, daylight-readable display - Rugged front for harsh environmental conditions - UV-protected decorative membrane - High degree of protection - Can be used in the extended outdoor temperature range at -30 °C to +70 °C with the TEK option in an air-conditioned control cabinet • Ideal for use in shipbuilding: - Diverse shipbuilding certificates (available soon) - 100% dimmable display backlighting, local and centralized - Console installation without special measures or restrictions - High-contrast display with wide reading angle - Design version with black frame possible • Features: - Daylight-readable, bright and dimmable LCD display - Splashwater-protected (IP66) - Rugged aluminum front, impact-resistant, UV-protected - Capacitive touch with 3 mm glass for harsh environmental conditions - Touch operation with thin gloves - Outdoor applications with extended temperature range (option) - ATEX Zone 2/22, FM Class I, Div. 2, UL Haz. Loc. - Marine certificates: DNV, GL, NK, ABS, LRS, CCS, RINA - Fan-free ■ Benefits • A panel for applications inside and outside the production hall • Extremely easy to read under diverse conditions • Ergonomic dimmer function for optimal reading in control desks • Can be connected to centralized dimming potentiometer (via PLC) • Familiar HMI functions (exception: Sm@rt option and high-speed keys), no new training ■ Application The Panel has a daylight-readable and dimmable display, making it predestined for use in control desks for, e.g. drill strings (oil & gas industry), ships (shipbuilding) and other exposed areas up to outdoor applications with the TEK Temperature Extension Kit option. 6/50 Siemens ST 80 / ST PC · 2013 The "MP 377 15" Touch daylight readable" has a powder-coated milled aluminum front that is impact-resistant, scratch-proof and highly resistant to chemicals. Touch operation uses projected capacitive technology protected against humidity, heat and dirt in harsh environments by a 3-mm pane of glass, without reflective membranes. The refined polyester-based decorative membrane is UV-resistant and protected against yellowing and embrittling. The LED-backlit and dimmable display is designed using transflective technology that allows a higher contrast than conventional, transmissive displays in extremely bright environments. The LED backlighting is dimmable using a slider on the process picture or centrally via the controller. Dimming is carried out using a gradation curve and is thus optimally ergonomically matched to the human eye. The Panel is based on the field-proven electronics card of the MP 377 with WinCC flexible functionality and the familiar interfaces. The entire mechanical design is prepared for good convection and temperature balance, for long service life, and for operation onboard ship, or other vehicles with corresponding shock and vibration stresses. © Siemens AG 2013 Customized Automation Oil & gas/chemicals/shipbuilding MP 377 15" Touch daylight readable ■ Technical specifications Multi Panels ■ Ordering data MP 377 15" Touch daylight readable General features Order No. MP 377 15" Touch daylight readable 6AV6644-8AB20-0AA1 Multi Panel 15" Touch with display suitable for natural-light viewing Display 15" TFT, transflective Brightness typ. 800 cd/m2 Contrast typ. 1000:1 Reading angle 160° Resolution 1024 x 768 MTBF of backlit display (at 25°C) 50,000 hrs LED backlighting, dimmable 0 (off) to 100% Input unit Touch, projected capacitive Drafting a quotation Power supply 24 V DC, typ. 1.5 A Special features Daylight-readable SIMATIC HMI specialists define the product modifications precisely in accordance with customer requirements. Front Material Aluminum, Autotex XE, glass Surface Powder-coated aluminum, polyester-based decorative membrane, glass (Mohs 7) Device seal HC / EPDM 4x4 Ambient conditions Degree of protection Front IP66, rear IP20 Ambient temperature during operation Front -30 °C to +70 °C, rear 0 °C to +50 °C, changeover time >= 3 min. Relative humidity 10% to 90%, without condensation Vibration IEC 60068, Part 2–6 (sine), constant acceleration 1 g Shock IEC 60068, Part 2–29, 15 g peak value, 11 ms duration Transport and storage conditions IEC 60721-3-2, Class 2M2 Transport/storage temperature -40 °C to +80 °C Approvals CE, cULus, C-Tick, ATEX Zone 2/22, UL haz. loc., FM Class I, Div. 2, shipbuilding certificates available soon Sector Oil & gas, ship, outdoor Can be connected to SIMATIC PC Multi Panels ■ More information Customized modification options • Integration into customized turnkey operator panels • Customized design This is followed by drafting a quotation with: • Non-recurring costs • Prototype costs • Standard unit prices • and the marginal conditions in the form of a product agreement (e.g. minimum quantity). The defined device can then be easily ordered using this product agreement and a customized Order No. HMI software HMI engineering software Configurable from WinCC flexible 2008, SP1 with add-ons 6 HMI Runtime software Special features Console mounting with an inclination of up to 90°, installation cutout as on MP 377 15" Touch (W x H) Dimensions External dimensions (W x H x D in mm) 400 x 315.5 x 106 Installation cutout (W x H x D in mm) 365.6 x 287 x 100 Weight 4.6 kg Siemens ST 80 / ST PC · 2013 6/51 © Siemens AG 2013 Customized Automation Notes 6 6/52 Siemens ST 80 / ST PC · 2013 7 © Siemens AG 2013 Appendix 7/2 7/3 Siemens Industry Training Course overview 7/4 Standards and approvals 7/5 Partners at Industry Automation and Drive Technologies Siemens contacts worldwide WinCC Competence Centers Solution Partner 7/5 7/6 7/7 7/8 7/8 7/10 7/10 7/11 Siemens Automation Cooperates with Education Applicable practical know-how Online Services Information and Ordering in the Internet and on DVD Information and Download Center Social Media, Mobile Media 7/12 7/13 Industry Services For the entire life cycle 7/17 Siemens Service Option for SIMATIC PC / PG 7/18 Expertise and services relating to all aspects of PC-based Automation 7/19 Software Licenses 7/21 Index 7/25 Order No. Index 7/27 Length key for connecting cables 7/28 Catalog improvement suggestions 7/32 Conditions of sale and delivery Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Appendix Siemens Industry Training ■ Faster and more applicable know-how: Hands-on training from the manufacturer Siemens Industry Training provides you with comprehensive support in solving your tasks. Training by the market leader in the industry enables you to make independent decisions with confidence. Especially where the optimum and efficient use of products and plants are concerned. You can eliminate deficiencies in existing plants, and exclude expensive faulty planning right from the beginning. ■ Highlights Siemens Industry Training Top trainers Our trainers are skilled teachers with direct practical experience. Course developers have close contact with product development, and directly pass on their knowledge to the trainers. Practical experience The practical experience of our trainers enables them to teach theory effectively. But since theory can be pretty drab, we attach great importance to practical exercises which can comprise up to half of of the course time. You can therefore immediately implement your new knowledge in practice. We train you on stateof-the-art methodically/didactically designed training equipment. This training approach will give you all the confidence you need. Wide variety With a total of about 300 local attendance courses, we train the complete range of Siemens Industry products as well as interaction of the products in systems. Tailor-made training We are only a short distance away. You can find us at more than 50 locations in Germany, and in 62 countries worldwide. You wish to have individual training instead of one of our 300 courses? Our solution: We will provide a program tailored exactly to your personal requirements. Training can be carried out in our Training Centers or at your company. First-class know-how directly pays for itself: In shorter startup times, high-quality end products, faster troubleshooting and reduced downtimes. In other words, increased profits and lower costs. Achieve more with Siemens Industry Training • Shorter times for startup, maintenance and servicing • Optimized production operations • Reliable configuration and startup • Minimization of plant downtimes • Flexible plant adaptation to market requirements • Compliance with quality standards in production • Increased employee satisfaction and motivation • Shorter familiarization times following changes in technology and staff ■ Contact Visit our site on the Internet at: www.siemens.com/sitrain or let us advise you personally. 7 Siemens Industry Training Customer Support Germany: Phone: +49 (911) 895-7575 Fax: +49 (911) 895-7576 E-Mail: info@sitrain.com 7/2 Siemens ST 80 / ST PC · 2013 The right mixture: Blended learning "Blended learning" is a combination of various training media and sequences. For example, a local attendance course in a Training Center can be optimally supplemented by a teach-yourself program as preparation or follow-up. Additional effect: Reduced traveling costs and periods of absence. © Siemens AG 2013 Appendix Siemens Industry Training ■ Training offer for SIMATIC HMI This page contains an overview of the SITRAIN training offer for SIMATIC HMI operator control and monitoring systems as well as for PC-based Automation. Depending on your demands we’ll make you fit for specific applications or teach you important background knowledge about products and systems. All courses contain the largest possible share of practical exercises so that training can be carried out very intensively in very small groups. Further information regarding course contents, dates and prices can be found in the Internet at: www.siemens.com/sitrain ■ SITRAIN courses for SIMATIC HMI / PC-based Automation Commissioning engineers, configuration engineers Programmers Service personnel Project managers, project team members Operators, users Decision makers, sales personnel Title Maintenance personnel Target Group Duration/ Medium Short title ■ SIMATIC WinCC based onTIA Portal ✔ ✔ ✔ ✔ ✔ 3 days TIA-WCCSUP ✔ ✔ ✔ ✔ ✔ 3 days TIA-WCCM ✔ ✔ ✔ ✔ ✔ 5 days TIA-WCCS ✔ ✔ ✔ ✔ ✔ WBT WT-TIAWMUP SIMATIC WinCC flexible, system course 1 ✔ ✔ ✔ ✔ ✔ 3 days ST-WCCFSYS1 SIMATIC WinCC flexible, system course 2 ✔ ✔ ✔ ✔ 3 days ST-WCCFSY2 SIMATIC WinCC, system course ✔ ✔ ✔ ✔ 5 days ST-BWINCCS SIMATIC WinCC, advanced configuration, options for networking and access to database ✔ ✔ 5 days ST-BWINOND ANSI-C in the SIMATIC World, Introduction ✔ ✔ 5 days ST-SIMACE SIMATIC TIA Portal WinCC SCADA retraining course TIA SIMATIC TIA Portal WinCC on the machine level TIA SIMATIC TIA Portal WinCC SCADA TIA SIMATIC TIA Portal WinCC on the machine level TIA ■ SIMATIC WinCC flexible ■ SIMATIC WinCC V7.x ✔ ✔ ✔ 7 ■ SIMATIC WinCC V7.x Market-specific Solutions Energy management Energy management with SIMATIC powerrate for WinCC ✔ ✔ ✔ ✔ ✔ 3 days ST-EMPRWCC Energy management with B.Data ✔ ✔ ✔ ✔ ✔ 4 days ST-EMBDATA TIA These courses are based on the new engineering platform TIA Portal. Siemens ST 80 / ST PC · 2013 7/3 © Siemens AG 2013 Appendix Standards and approvals ■ Operating system licenses for SIMATIC PC/PG The accompanying operating system license is only valid for installation on the supplied SIMATIC PC/PG. Installation can only be performed on these SIMATIC systems in accordance with Microsoft OEM licensing regulations. ■ Standards UL (U) and CSA (C) All HMI products comply with the standards UL (U) and CSA (C), or the approval procedure has been applied for. Products which have no approval are specially marked (see ordering data of the products). ■ CE marking The electronic products described in this catalog comply with the requirements and protection objectives of the following EC directives insofar as they relate to the product concerned. They also comply with the corresponding harmonized European standards (EN) published for these products in the Official Journals of the European Community. • Directive 2004/108/EC of the European Parliament and Council on the approximation of the laws of the Member States relating to electromagnetic compatibility (EMC Directive) • Directive 2006/95/EC of the European Parliament and of the Council on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits (Low Voltage Directive) • Directive 94/9/EC of the European Parliament and the Council on approximation of the laws of the Member States concerning equipment and protective systems intended for use in potentially explosive atmospheres (ATEX Directive). • Directive 1999/5/EC of the European Parliament and of the Council on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity (RTTE Directive) The originals of the declarations of conformity are kept available for the responsible supervisory authorities at: SIMATIC HMI: Siemens AG I IA AS S ID Postfach 48 48 90327 Nürnberg Germany SIMATIC, SIMATIC NET, SIMATIC PC: Siemens AG IA AS EWA Postfach 19 63 92209 Amberg Germany Note on the EMC Directive: The installation instructions in the manuals must be adhered to when installing and operating the products described in this catalog. These contain, for example, important information on installation in cabinets and on the use of shielded cables. 7 7/4 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Appendix Partners at Industry Automation and Drive Technologies Siemens contacts worldwide ■ Overview At Siemens Industry Automation and Drive Technologies, more than 85 000 people are resolutely pursuing the same goal: longterm improvement of your competitive ability. We are committed to this goal. Thanks to our commitment, we continue to set new standards in automation and drive technology. In all industries – worldwide. At your service locally, around the globe for consulting, sales, training, service, support, spare parts ... on the entire Industry Automation and Drive Technologies range. Your personal contact can be found in our Contacts Database at: www.siemens.com/automation/partner You start by selecting a • Product group, • Country, • City, • Service. 7 Siemens ST 80 / ST PC · 2013 7/5 © Siemens AG 2013 Appendix Partners at Industry Automation and Drive Technologies WinCC Competence Centers ■ WinCC Competence Centers The WinCC Competence Centers are Siemens-internal partners. They offer a wide range of products and services designed to make optimal economic and system-oriented use of the openness and integration capability of WinCC. In addition to the development of standard solutions/add-on products, they are authorized to implement customized/ industry-specific solutions in the areas of application development and system integration on the basis of WinCC. The portfolio is rounded off with consulting services, project-related training, and workshops for decision-makers and users. Sector competence in addition to automation expertise and WinCC system know-how ensure professional and efficient solutions. The software is, of course, developed in compliance with recognized standards on the basis of certified quality management in accordance with DIN ISO 9001. 7 7/6 Siemens ST 80 / ST PC · 2013 You can find more information on the Internet at: www.siemens.com/wincc-competence-center © Siemens AG 2013 Appendix Partners at Industry Automation and Drive Technologies Siemens Solution Partner Automation ■ Overview Siemens Solution Partner Automation Solution Partner Finder Solution Partner: Highest quality - guaranteed The products and systems from Siemens Industry Automation and Drive Technologies offer the ideal platform for all automation applications. Under the name of Siemens Solution Partner Automation, selected system integrators around the world act as uniformly qualified solution providers for the Siemens range of products and services in the fields of automation and drives. Day after day, they utilize their qualified product and system know-how as well as their excellent industry expertise to your advantage – for all requirements. The partner emblem is the guarantee and indicator of proven quality. The basis for this are defined quality features that identify Solution Partners as reliable and competent solution providers: • Solution quality Always a good result with tried and tested solutions expertise. • Expert quality Certified technical competence ensures maximum efficiency. • Project quality With proven project experience straight to the target. • Portfolio quality Comprehensive portfolio for state-of-the-art solutions from a single source. The Siemens Solution Partner Program helps you to find the optimum partner for your specific requirements. Support is provided by the Solution Partner Finder, a comprehensive online platform that showcases the profiles of all our solution partners. You can convince yourself of the competence of the respective Solution Partner by means of the references provided. Various search criteria are available for this purpose. Once you have located a partner, you are only one small step away from contacting them. Find the right partner here for your specific task and convince yourself of the solution competence provided: www.siemens.com/automation/partnerfinder Additional information on the Siemens Solution Partner Program is available online at: www.siemens.com/automation/solutionpartner 7 Siemens ST 80 / ST PC · 2013 7/7 © Siemens AG 2013 Appendix Siemens Automation Cooperates with Education Applicable practical know-how ■ Comprehensive teaching support for educational institutions • The new TIA Portal training materials for SIMATIC S7-1200 are available in English, German, French, Italian, Spanish and Chinese for download. www.siemens.com/sce/documents Trainer packages for hands-on learning Siemens Automation Cooperates with Education (SCE) offers a global system for sustained support of technical skills. SCE supports educational institutions in their teaching assignment in the industrial automation sector and offers added value in the form of partnerships, technical expertise, and know-how. As the technological leader, our comprehensive range of services can support you in the knowledge transfer for Industry 4.0. Our services at a glance • Training curriculums for your lessons • Trainer packages for hands-on learning • Courses convey up-to-date, specialist knowledge • Support for your projects/textbooks • Complete didactic solutions from our partners • Personal contact for individual support Training curriculums for your lessons 7 Use our profound industrial know-how for practice-oriented and individual design of your course. We offer you more than 100 didactically prepared training curriculums on the topics of automation and drives technology free of charge. These materials are perfectly matched to your curricula and syllabuses, and optimally suited for use with our trainer packages. This takes into account all aspects of a modern industrial solution: installation, configuration, programming, and commissioning. All documents, including projects, can be individually matched to your specific requirements. Particular highlights: • With the new SIMATIC PCS 7 curriculums and trainer packages, you can pass on basic, practice-oriented PCS 7 knowledge at universities within about 60 hours (= 1 semester), using plant simulation. 7/8 Siemens ST 80 / ST PC · 2013 Our SCE trainer packages offer a specific combination of original industrial components which are perfectly matched to your requirements and can be conveniently used in your course. These price reduced bundles available exclusively to schools include innovative and flexible hardware and software packages. SCE can currently offers more than 90 SCE trainer packages including related equipment. These cover both the factory and process automation sectors. You can use them to impart the complete course contents on industrial automation at a very low cost. Trainer packages are available for: • Introduction to automation technology with LOGO! logic module and SIMATIC S7-1200 compact controller • PLC engineering with SIMATIC S7 hardware and STEP 7 software (S7-300, S7-1500 and TIA Portal) • Operator control and monitoring with SIMATIC HMI • Industrial networking over bus systems with SIMATIC NET (PROFINET, PROFIBUS, IO-Link) • Sensor systems with VISION, RFID and SIWAREX • Process automation with SIMATIC PCS 7 • Power Monitoring Devices SENTRON PAC 4200 • Motor Management SIMOCODE • Networked drive and motion technologies with SINAMICS/ SIMOTION • CNC programming with SinuTrain Important ordering notes: Only the following institutions are authorized to obtain trainer packages: vocational schools, Colleges and Universities, in-house vocational training departments, non commercial research institutions and non commercial training departments. To purchase a trainer package, you require a specific end-use certificate, which you can obtain from your regional sales office. www.siemens.com/sce/tp © Siemens AG 2013 Appendix Siemens Automation Cooperates with Education Applicable practical know-how ■ Comprehensive teaching support for educational institutions (continued) Courses convey up-to-date specialist knowledge We can provide you with consulting for selected projects and support from your personal SCE contact as well as our web based and regional Customer Support. As a particular service, SCE supports technical authors with our know-how as well as with intensive technical consulting. Siemens library of special textbooks covering the industrial automation sector provides an additional resource for you and your students. These can be found at the SCE web site. www.siemens.com/sce/contact www.siemens.com/sce/books Complete didactic solutions Profit from our excellent know-how as the leader in industrial technologies. We offer you specific courses for automation and drive technology worldwide. These support you in the practiceoriented transferring of product and system know-how, are in conformance with curriculums, and derived from the training fields. Compact technical courses especially for use at universities are also available. Our range of courses comprises a wide variety of training modules based on the principle of Totally Integrated Automation (TIA). The focus is on the same subject areas as with the SCE trainer packages. Every PLC and drive course is oriented on state-of-the-art technology. Your graduates can thus be prepared optimally for their future professional life. In some countries we are offering classes based on our training curriculums. Please inquire with your SCE contact partner. www.siemens.com/sce/contact Support for your projects/textbooks Our partners for learning systems offer a wide range of training systems and solutions for use in your courses or laboratory. These models have been designed based on our trainer packages and thus save you the time and cost of selfconstruction of individual components. The Partner systems provide you with simple and effective help in the fulfillment of your teaching assignment. www.siemens.com/sce/partner Contact for individual support You can find your personal SCE contact on our Internet site. Your local SCE Promoter will answer all your questions concerning the complete SCE offering, and provide you with timely and competent information about innovations. When you encounter challenges, you can profit from our global team of excellence. If a direct SCE contact is not listed for your country, please contact your local Siemens office. www.siemens.com/sce/contact SCE Support Finder for your Internet request You are an educator and need support on the topic of industry automation? Send us your request: www.siemens.com/sce/supportfinder Automation and drive technology is characterized by continuous and rapid developments. Service and Support therefore play an important role. 6FDQWKH45 FRGHIRUIXUWKHU LQIRUPDWLRQ 6&(KRPHSDJH Siemens ST 80 / ST PC · 2013 7/9 7 © Siemens AG 2013 Appendix Online Services Information and Ordering in the Internet and on DVD ■ Siemens Industry Automation and Drive Technologies in the WWW A detailed knowledge of the range of products and services available is essential when planning and configuring automation systems. It goes without saying that this information must always be fully up-to-date. Siemens Industry Automation and Drive Technologies has therefore built up a comprehensive range of information in the World Wide Web, which offers quick and easy access to all data required. Under the address www.siemens.com/industry you will find everything you need to know about products, systems and services. ■ Product Selection Using the Interactive Catalog CA 01 of Industry Detailed information together with convenient interactive functions: The interactive catalog CA 01 covers more than 80 000 products and thus provides a full summary of the Siemens Industry Automation and Drive Technologies product base. Here you will find everything that you need to solve tasks in the fields of automation, switchgear, installation and drives. All information is linked into a user interface which is easy to work with and intuitive. After selecting the product of your choice you can order at the press of a button, by fax or by online link. Information on the interactive catalog CA 01 can be found in the Internet under www.siemens.com/automation/ca01 or on DVD. ■ Easy Shopping with the Industry Mall The Industry Mall is the virtual department store of Siemens AG on the Internet. Here you have access to a huge range of products presented in electronic catalogs in an informative and attractive way. Data transfer via EDIFACT allows the whole procedure from selection through ordering to tracking of the order to be carried out online via the Internet. 7 Numerous functions are available to support you. For example, powerful search functions make it easy to find the required products, which can be immediately checked for availability. Customer-specific discounts and preparation of quotes can be carried out online as well as order tracking and tracing. Please visit the Industry Mall on the Internet under: www.siemens.com/industrymall 7/10 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Appendix Online Services Information and Download Center Social Media, Mobile Media ■ Downloading Catalogs In addition to numerous other useful documents, you can also find the catalogs listed on the back inside cover of this catalog in the Information and Download Center. Without having to register, you can download these catalogs in PDF format or increasingly as digital page-turning e-books. The filter dialog box above the first catalog displayed makes it possible to carry out targeted searches. If you enter “MD 3” for example, you will find both the MD 30.1 and MD 31.1 catalogs. If you enter “ST 70” both the ST 70 catalog and the associated news or add-ons are displayed. Visit us on the web at: www.siemens.com/industry/infocenter ■ Social Media Connect with Siemens through social media: visit our social networking sites for a wealth of useful information, demos on products and services, the opportunity to provide feedback, to exchange information and ideas with customers and other Siemens employees, and much, much more. Stay in the know and follow us on the ever-expanding global network of social media. Connect with Siemens Industry at our central access point: www.siemens.com/industry/socialmedia Or via our product pages at: www.siemens.com/automation or www.siemens.com/drives To find out more about Siemens' current social media activities visit us at: www.siemens.com/socialmedia ■ Mobile Media Discover the world of Siemens. We are also constantly expanding our offering of cross-platform apps for smartphones and tablets. You will find the current Siemens apps at the app store (iOS) or at Google Play (Android). The Siemens app, for example, tells you all about the history, latest developments and future plans of the company – with informative pictures, fascinating reports and the most recent press releases. Siemens ST 80 / ST PC · 2013 7/11 7 © Siemens AG 2013 Appendix Industry Services Your machines and plant can do more – with Industry Services. Whether it is production or process industry - in view of rising cost pressure, growing energy costs, and increasingly stringent environmental regulations, services for industry are a crucial competitive factor in manufacturing as well as in process industries. All over the world Siemens supports its customers with product, system, and application-related services throughout the entire life cycle of a plant. Right from the earliest stages of planning, engineering, and building, all the way to operation and modernization. These services enable customers to benefit from the Siemens experts’ unique technological and product knowledge and industry expertise. Thus downtimes are reduced and the utilization of resources is optimized. The bottom line: increased plant productivity, flexibility, and efficiency, plus reduced overall costs. Discover all advantages of our service portfolio: www.siemens.com/industry-services {GjGMGG lGz l GMG G lGz {GjGMGG lGz l GMG lGz Modernization Modernization t¡GM G v¡Gz Planning Planning Online Support Technical Support Spare Parts Repair Services Field Services Training Operation Operation {GjGMGG lGz Engineer Engineer & & Build Build l GMG lGz wGtGMGG jGt zG l GMGlG t¡GMGv¡Gz 7 G_DA65_EN_00270 Siemens supports its clients with technology based Services across a plants entire life cycle. 7/12 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Appendix Industry Services Industry Services for the entire life cycle Online Support Online support is a comprehensive information system for all questions relating to products, systems, and solutions that Siemens has developed for industry over time. With more than 300,000 documents, examples and tools, it offers users of automation and drive technology a way to quickly find up-to-date information. The 24-hour service enables direct, central access to detailed product information as well as numerous solution examples for programming, configuration and application. The content, in six languages, is increasingly multimediabased – and now also available as a mobile app. Online support’s “Technical Forum” offers users the opportunity to share information with each other. The “Support Request” option can be used to contact Siemens’ technical support experts. The latest content, software updates, and news via newsletters and Twitter ensure that industry users are always up to date. www.siemens.com/industry/onlinesupport Online Support App Using the Online Support app, you can access over 300,000 documents covering all Siemens industrial products - anywhere, any time. Regardless of whether you need help implementing your project, fault-finding, expanding your system or are planning a new machine. You have access to FAQs, manuals, certificates, characteristics curves, application examples, product notices (e.g. announcements of new products) and information on successor products in the event that a product is discontinued. Just scan the product code printed on the product directly using the camera of your mobile device to immediately see all technical information available on this product at a glance. The graphical CAx information (3D model, circuit diagrams or EPLAN macros) is also displayed. You can forward this information to your workplace using the e-mail function. find your favorite pages – articles you need frequently – under “mySupport”. You also receive selected news on new functions, important articles or events in the News section. Scan the QR code for information on our Online Support app. The app is available free of charge from the Apple App Store (iOS) or from Google Play (Android). www.siemens.com/industry/onlinesupportapp The search function retrieves product information and articles and supports you with a personalized suggestion list. You can Technical Support The ability to quickly analyze system and error messages and take appropriate action are key factors in ensuring that plants run safely and efficiently. Questions can arise at any time and in any industry, whether it’s an individual product or a complete automation solution. Siemens technical support offers individual technical assistance in matters related to functionality, how to operate, applications, and fault clearance in industrial products and systems – at any time and globally, over the phone, by email, or via remote access. Experienced experts from Siemens answer incoming questions promptly. Depending on the requirements, they first consult specialists in the areas of development, on-site services, and sales. Technical support is also available for discontinued products that are no longer available. Using the support request number, any inquiry can be clearly identified and systematically tracked. 7 Siemens ST 80 / ST PC · 2013 7/13 © Siemens AG 2013 Appendix Industry Services Industry Services for the entire life cycle Spare Parts Drive and automation systems must be available at all times. Even a single missing spare part can bring the entire plant to a standstill – and result in substantial financial losses for the operator. The spare parts services from Siemens protects against such losses – with the aid of quickly available, original spare parts that ensure smooth interaction with all other system components. Spare parts are kept on hand for up to ten years; defective parts can be returned. For many products and solutions, individual spare parts packages ensure a preventive stock of spare parts on-site. The spare parts services is available around the world and around the clock. Optimum supply chain logistics ensure that replacement components reach their destination as quickly as possible. Siemens’ logistics experts take care of planning and management as well as procurement, transportation, customs handling, warehousing, and complete order management for spare parts. Repair Services Reliable electrical and electronic equipment is crucial for operating continuous processes. That is why it is essential that motors and converters always undergo highly specialized repair and maintenance. Siemens offers complete customer and repair services – on site and in repair centers – as well as technical emergency services worldwide. The repair services include all measures necessary to quickly restore the functionality of defective units. In addition, services such as spare parts logistics, spare parts storage and rapid manufacturing are available to plant operators in all verticals. With a global network of certified repair shops operated by Siemens as well as third parties, Siemens handles the maintenance and overhaul of motors, converters, and other devices as an authorized service partner. Field Services It’s a top priority in all industries: the availability of plants and equipment. Siemens offers specialized maintenance services such as inspection and upkeep as well as rapid fault clearance in industrial plants – worldwide, continuously, and even with emergency services as needed. The services include startup as well as maintenance and fault clearance during operation. The startup service includes checking the installation, function tests, parameterization, integration tests for machines and plants, trial operation, final acceptance, and employee training. All services, including remote maintenance of drives, are also available as elements of customized service contracts. 7 7/14 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Appendix Industry Services Industry Services for the entire life cycle Training Increasingly, up-to-date knowledge is becoming a determining factor in success. One of the key resources of any company is well-trained staff that can make the right decision at the right moment and take full advantage of the potential. With SITRAIN – Training for Industry, Siemens offers comprehensive advanced training programs. The technical training courses convey expertise and practical knowledge directly from the manufacturer. SITRAIN covers Siemens’ entire product and system portfolio in the field of automation and drives. Together with the customer, Siemens determines the company’s individual training needs and then develops an advanced training program tailored to the desired requirements. Additional services guarantee that the knowledge of all Siemens partners and their employees is always up-to-date. Technical Consulting & Engineering Support The efficiency of plants and processes leads to sustainable economic success. Individual services from Siemens help save substantial time and money while also guaranteeing maximum safety. Technical consulting covers the selection of products and systems for efficient industrial plants. The services include planning, consulting, and conceptual design as well as product training, application support, and configuration verification – in all phases of a plant’s lifecycle and in all questions related to product safety. Engineering support offers competent assistance throughout the entire project, from developing a precise structure for startup to product-specific preparation for implementation as well as support services in areas such as prototype development, testing and acceptance. Energy & Environmental Services Efficient energy use and resource conservation – these top sustainability concerns pay off – both for the environment and for companies. Siemens offers integrated solutions that unlock all technical and organizational potential for successful environmental management. Customized consulting services are aimed at sustainably lowering the cost of energy and environmental protection and thus increasing plant efficiency and availability. The experts provide support in the conceptual design and implementation of systematic solutions in energy and environmental management, enabling maximum energy efficiency and optimized water consumption throughout the entire company. Improved data transparency makes it possible to identify savings potential, reduce emissions, optimize production processes, and thereby noticeably cut costs. 7 Siemens ST 80 / ST PC · 2013 7/15 © Siemens AG 2013 Appendix Industry Services Industry Services for the entire life cycle Modernization & Optimization Services High machine availability, expanded functionality and selective energy savings – in all industries, these are decisive factors for increasing productivity and lowering costs. Whether a company wants to modernize individual machines, optimize drive systems, or upgrade entire plants, Siemens’ experts support the projects from planning to commissioning. Expert consulting and project management with solution responsibility lead to security and make it possible to specifically identify savings potential in production. This secures investments over the long term and increases economic efficiency in operation. Plant Maintenance & Condition Monitoring Modern industrial plants are complex and highly automated. They must operate efficiently in order to ensure the company’s competitive strength. In addition, the steadily increasing networking of machines and plants require consistent security concepts. Maintenance and status monitoring as well as the implementation of integrated security concepts by Siemens’ experts support optimum plant use and avoid downtime. The services include maintenance management as well as consulting on maintenance concepts, including the complete handling and execution of the necessary measures. Complete solutions also cover remote services, including analysis, remote diagnosis, and remote monitoring. These are based on the Siemens Remote Services platform with certified IT security. Service Contracts 7 Making maintenance costs calculable, reducing interfaces, speeding up response times, and unburdening the company’s resources – the reduced downtimes that these measures achieve increase the productivity of a plant. Service contracts from Siemens make maintenance and repairs more cost-effective and efficient. The service packages include local and remote maintenance for a system or product group in automation and drive technology. Whether you need extended service periods, defined response times, or special maintenance intervals, the services are compiled individually and according to need. They can be adjusted flexibly at any time and used independently of each other. The expertise of Siemens’ specialists and the capabilities of remote maintenance thus ensure reliable and fast maintenance processes throughout a plant’s entire lifecycle. 7/16 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Appendix Siemens Service Option for SIMATIC PC / PG ■ Siemens Service Option for SIMATIC PC / PG Product family Order No. Service Option Order designation SIMATIC Rack PC A5E00510072 36 months service option for SIMATIC Rack PC and Box PC A5E00509961 36 months service option for SIMATIC Panel PCs A5E00510007 36 months service option for SIMATIC Field PG M2/M3 • SIMATIC IPC547 • SIMATIC IPC647 • SIMATIC IPC847 SIMATIC Box PC • SIMATIC IPC227 • SIMATIC IPC427 • SIMATIC IPC627 • SIMATIC IPC827 The expanded hardware service for SIMATIC PC/PG products SIMATIC Panel PC Purchasing and registering this additional agreement for a SIMATIC PC/PG extends the time period for free repairs of this device to 36 months after delivery. • SIMATIC IPC477D/ HMI IPC477 Scope of services of the service option within the period of service (36 months): • Free1) repair during the period of service at one of our authorized repair centers near you The addresses of our worldwide partners can be found on the Internet at www.siemens.com/asis • Within the agreed contractual period, Siemens will bear the costs that are incurred in the repair center (labor and materials/replacement parts), which are needed to restore the functions2) of the hardware • Siemens will also assume the return shipping costs of the repaired device from the repair center to the customer • SIMATIC HMI IPC677 1) Wear and tear as well as problems that arise due to improper handling of the devices are not included. 2) For hard disk defects that require the system to be restored, the repair service will only cover restoring the installation to its original condition ex works. The uploading of additional application software, drivers and setting up the operating software are not covered by the free repair service. • SIMATIC IPC277 • SIMATIC HMI IPC577 SIMATIC Field PG • SIMATIC Field PG M2 • SIMATIC Field PG M3 Ordering and registering the additional agreement: • Select the appropriate order number for the optional package based on the family of products and place your order • Scope of delivery: Description of services in 4 languages + service device label with a license number for identifying the additional agreement on the device • Activation of the service license number for a SIMATIC PC/ SIMATIC PG via the Internet (www.siemens.com/ped): The registration must be completed within the first 90 days after initial delivery of the device! 7 Siemens ST 80 / ST PC · 2013 7/17 © Siemens AG 2013 Appendix Expertise and services relating to all aspects of PC-based Automation ■ Overview Expertise and services relating to all aspects of PC-based Automation Do you require support with the dimensioning and options of a PC-based Automation project, or even engineering support? Specifically for this purpose, Siemens has established a team of specialists in Cologne and Milan who work closely with Development and Product Marketing and can thus provide our sales departments worldwide with competent support in PC-based Automation. ■ Our core competencies • Design of PC-based Automation systems from Siemens • Integrated, customer-specific technology (add-ons) using high-level languages (C++) in Windows or real-time environments • Knowledge transfer/workshops for the integration of thirdparty components, as well as for applications using the Open Development Kit (ODK) • Technology and application know-how • Development of add-ons for WinAC and WinCC flexible ■ Reference applications • Fast recording of measured values • Software blocks for drives library • Customer-specific communications via Ethernet (OPC/ActiveX, TCP socket) • Synchronous operation, flying shear, table interpolation for electric and hydraulic axes • Integration of PCI cards into PC-based Automation applications (e.g. WinAC and ASi-Bus) • Customer-specific development and integration of C++ programs • Database connections • Integration of complex control algorithms 7 ■ Contacts Activation of the Competence Centers for your application via your regional contact. If you do not yet have a contact person in your region, just go to: www.siemens.com/automation/partner 7/18 Siemens ST 80 / ST PC · 2013 The latest information about the workshops offered can be found on the Internet: www.siemens.com/pc-based © Siemens AG 2013 Appendix Software Licenses ■ Overview Software types Software requiring a license is categorized into types. The following software types have been defined: • Engineering software • Runtime software Engineering software This includes all software products for creating (engineering) user software, e.g. for configuring, programming, parameterizing, testing, commissioning or servicing. Data generated with engineering software and executable programs can be duplicated for your own use or for use by thirdparties free-of-charge. Runtime software This includes all software products required for plant/machine operation, e.g. operating system, basic system, system expansions, drivers, etc. The duplication of the runtime software and executable programs created with the runtime software for your own use or for use by third-parties is subject to a charge. You can find information about license fees according to use in the ordering data (e.g. in the catalog). Examples of categories of use include per CPU, per installation, per channel, per instance, per axis, per control loop, per variable, etc. Information about extended rights of use for parameterization/configuration tools supplied as integral components of the scope of delivery can be found in the readme file supplied with the relevant product(s). License types Siemens Industry Automation & Drive Technologies offers various types of software license: • Floating license • Single license • Rental license • Rental floating license • Trial license • Demo license • Demo floating license Floating license The software may be installed for internal use on any number of devices by the licensee. Only the concurrent user is licensed. The concurrent user is the person using the program. Use begins when the software is started. A license is required for each concurrent user. Single license Unlike the floating license, a single license permits only one installation of the software per license. The type of use licensed is specified in the ordering data and in the Certificate of License (CoL). Types of use include for example per instance, per axis, per channel, etc. One single license is required for each type of use defined. Rental license A rental license supports the "sporadic use" of engineering software. Once the license key has been installed, the software can be used for a specific period of time (the operating hours do not have to be consecutive). One license is required for each installation of the software. Rental floating license The rental floating license corresponds to the rental license, except that a license is not required for each installation of the software. Rather, one license is required per object (for example, user or device). Trial license A trial license supports "short-term use" of the software in a nonproductive context, e.g. for testing and evaluation purposes. It can be transferred to another license. Demo license The demo license support the "sporadic use" of engineering software in a non-productive context, for example, use for testing and evaluation purposes. It can be transferred to another license. After the installation of the license key, the software can be operated for a specific period of time, whereby usage can be interrupted as often as required. One license is required per installation of the software. Demo floating license The demo floating license corresponds to the demo license, except that a license is not required for each installation of the software. Rather, one license is required per object (for example, user or device). Certificate of license (CoL) The CoL is the licensee's proof that the use of the software has been licensed by Siemens. A CoL is required for every type of use and must be kept in a safe place. Downgrading The licensee is permitted to use the software or an earlier version/release of the software, provided that the licensee owns such a version/release and its use is technically feasible. Delivery versions Software is constantly being updated. The following delivery versions • PowerPack • Upgrade can be used to access updates. Existing bug fixes are supplied with the ServicePack version. PowerPack PowerPacks can be used to upgrade to more powerful software. The licensee receives a new license agreement and CoL (Certificate of License) with the PowerPack. This CoL, together with the CoL for the original product, proves that the new software is licensed. A separate PowerPack must be purchased for each original license of the software to be replaced. Upgrade An upgrade permits the use of a new version of the software on the condition that a license for a previous version of the product is already held. The licensee receives a new license agreement and CoL with the upgrade. This CoL, together with the CoL for the previous product, proves that the new version is licensed. A separate upgrade must be purchased for each original license of the software to be upgraded. Siemens ST 80 / ST PC · 2013 7/19 7 © Siemens AG 2013 Appendix Software Licenses ■ Overview ServicePack ServicePacks are used to debug existing products. ServicePacks may be duplicated for use as prescribed according to the number of existing original licenses. License key Siemens Industry Automation & Drive Technologies supplies software products with and without license keys. The license key serves as an electronic license stamp and is also the "switch" for activating the software (floating license, rental license, etc.). The complete installation of software products requiring license keys includes the program to be licensed (the software) and the license key (which represents the license). 7 7/20 Siemens ST 80 / ST PC · 2013 Software Update Service (SUS) As part of the SUS contract, all software updates for the respective product are made available to you free of charge for a period of one year from the invoice date. The contract will automatically be extended for one year if it is not canceled three months before it expires. The possession of the current version of the respective software is a basic condition for entering into an SUS contract. You can download explanations concerning license conditions from www.siemens.com/automation/salesmaterial-as/catalog/en/ terms_of_trade_en.pdf © Siemens AG 2013 Appendix Index Numerics 19" slide-in keyboard PS/2 with trackball ......................... 1-phase, 24 V DC/10 A (SITOP PSU100S)....................... 1-phase, 24 V DC/20 A (SITOP PSU100S)....................... 24 V DC uninterruptible power supplies .......................... 3-phase, 24 V DC/10 A (SITOP PSU300S)....................... 3-phase, 24 V DC/20 A (SITOP PSU300S)....................... 3-phase, 24 V DC/40 A (SITOP PSU300S)....................... C (continued) 5/169 5/171 5/171 5/174 5/172 5/172 5/173 A A whole world of operator control and monitoring ............... 1/6 Accessories for fully enclosed HMI devices ...................... 3/16 Adapter sets ....................................................................... 3/16 Additional accessories ..................................................... 2/101 Applicable practical know-how ............................................ 7/8 Automotive industry............................................................ 6/30 B Basic Panels....................................................................... 2/12 Basic Panels – Standard .................................................... 2/12 Batteries ........................................................................... 2/137 Battery module 1.2 Ah...................................................... 5/182 Battery module 2.5 Ah...................................................... 5/183 Battery module 3.2 Ah...................................................... 5/183 Battery module 7 Ah......................................................... 5/184 Battery module 12 Ah....................................................... 5/184 Box PC................................................................................ 5/27 BSP SIMATIC IPC V4.0 for RMOS3 .................................. 5/152 C Catalog improvement suggestions .................................... 7/28 Charging station ................................................................. 2/74 Comfort Panels................................................................... 2/26 Comfort Panels – Standard ................................................ 2/26 Communication – Industrial Ethernet ............................... 5/186 Communication – PROFIBUS ........................................... 5/208 Conditions of sale and delivery .......................................... 7/32 Connecting cables ........................................................... 2/112 Connection options to SIMATIC IPCs ............................... 5/186 Connection options to SIMATIC PCs ................................ 5/208 Connectors/converters/adapters ..................................... 2/104 Controllers from other manufacturers................................. 2/79 Course overview................................................................... 7/3 CP 1604............................................................................ 5/187 CP 1612 A2 ...................................................................... 5/189 CP 1613 A2 ...................................................................... 5/191 CP 1616............................................................................ 5/188 CP 1623............................................................................ 5/192 CP 1628............................................................................ 5/193 CP 5512............................................................................ 5/219 CP 5603............................................................................ 5/209 CP 5612............................................................................ 5/221 CP 5613 A2 ...................................................................... 5/211 CP 5614 A2 ...................................................................... 5/213 CP 5622............................................................................ 5/223 CP 5623............................................................................ 5/215 CP 5624............................................................................ 5/217 CP 5711............................................................................ 5/225 Customized adaptations ...................................................... 6/4 Customized Automation ....................................................... 6/2 Customized hardware .......................................................... 6/6 Customized software.......................................................... 6/20 D DC UPS module 6 A ......................................................... 5/181 DC UPS module 15 A ....................................................... 5/181 DC UPS module 40 A ....................................................... 5/182 DC UPS with battery modules .......................................... 5/179 DC UPS with capacitors ................................................... 5/176 Design products................................................................... 6/7 Devices with stainless steel front ....................................... 3/21 E EC31................................................................................... 5/93 Embedded bundles/Software packages.......................... 5/101 Embedded Controller ......................................................... 5/91 Examples of sector products ............................................. 6/26 Expansion components and accessories ........................ 5/153 Expansion modules .......................................................... 5/100 Expertise and services relating to all aspects of PC-based Automation.................................. 7/18 Extension units ................................................................... 3/17 7 Siemens ST 80 / ST PC · 2013 7/21 © Siemens AG 2013 Appendix Index F M Fasteners.......................................................................... 2/130 Fax form ............................................................................. 7/28 Flat Panels with stainless steel front................................... 6/46 Flat Panels, 10.4" for Panel PC ........................................... 6/38 Flexible front design concept for HMI products................. 6/11 Food and beverages industry/pharmaceuticals ................ 6/39 Front panel 15" Touch and Key for Panel PCs, resistant to honing oil ......................................................... 6/36 Front panel with motion keys at side .................................. 6/32 Fully enclosed HMI devices ................................................. 3/3 MASTERGUARD power supply........................................ 5/185 Memory media ................................................................. 2/116 Mobile Panel 277 10" Remote Operate .............................. 6/33 Mobile panel accessories .................................................. 2/99 Mobile Panels ..................................................................... 2/44 Mobile Panels – 170 series................................................. 2/45 Mobile Panels – 270 series................................................. 2/52 MP 277 8" Touch control console ....................................... 6/13 MP 377 15" Touch daylight readable.................................. 6/50 O G Gain transparency and lower costs ..................................... 1/2 General HMI accessories................................................... 2/96 General machine construction ........................................... 6/36 H HARDNET-IE S7-REDCONNECT...................................... 5/194 HMI connecting components ........................................... 2/105 HMI devices for hazardous areas ...................................... 3/25 HMI operator stations for the automobile industry ............. 6/30 HMI operator stations for turnkey products........................ 6/18 HMI Panels as rear-mounted devices ................................ 6/44 HMI software ........................................................................ 4/2 HMI Software in the TIA portal.............................................. 4/5 HMI stainless steel operator stations ................................. 6/48 I IE FC RJ45 Plug 2 x 2....................................................... 2/110 Industrial monitors and thin clients................................... 5/117 Industrial PC ......................................................................... 5/2 Industrial USB Hub 4.......................................................... 2/97 Industry Services................................................................ 7/12 Industry Services for the entire life cycle ........................................................ 7/13 Information and Download Center ..................................... 7/11 Information and Ordering in the Internet and on DVD ................................................. 7/10 Input and output devices ................................................. 5/167 IP65 keyboards .................................................................. 3/19 IP65 membrane keyboard, desk version ......................... 5/168 K Key Panels............................................................................ 2/6 L 7 Labeling strips.................................................................. 2/135 Length key for connecting cables...................................... 7/27 7/22 Siemens ST 80 / ST PC · 2013 OEM products .................................................................... 6/10 Oil & gas/chemicals/shipbuilding....................................... 6/49 Online Services .................................................................. 7/10 OPC server for Industrial Ethernet ................................... 5/201 OPC server for PROFIBUS ............................................... 5/229 Order No. Index.................................................................. 7/25 P Panel PC............................................................................. 5/50 Panels and Panel PCs with stainless steel front................. 6/41 Partners at Industry Automation and Drive Technologies .... 7/5 PC I/O ............................................................................... 5/156 PLCs from other manufacturers ......................................... 2/90 PN CBA OPC server......................................................... 5/203 Power supply unit ............................................................. 2/100 Protective covers.............................................................. 2/122 Protective films ................................................................. 2/124 R Rack PC................................................................................ 5/3 Remote Operate Software .................................................. 6/21 Renewable energy ............................................................. 6/27 RMOS3 real-time operating system ................................. 5/146 RMOS3 V3.50 real-time operating system ....................... 5/147 RMOS3-GNU V3.0............................................................ 5/149 RMOS3-GRAPHX V1.0 ..................................................... 5/151 RMOS3-TCP/IP V3.0......................................................... 5/150 RS485 bus connector....................................................... 2/109 © Siemens AG 2013 Appendix Index S S (continued) S7 OPC Redundancy for Industrial Ethernet.................... 5/205 S7 OPC Redundancy for PROFIBUS ............................... 5/230 S7 OpenModbusTCP ......................................................... 6/24 SCADA System SIMATIC WinCC ....................................... 4/88 SCADA System SIMATIC WinCC Open Architecture ....... 4/146 SCD desk monitors SCD 19101 ....................................... 5/134 SCD monitors 1900 .......................................................... 5/136 Service sets ...................................................................... 2/118 Siemens Automation Cooperates with Education ................ 7/8 Siemens contacts worldwide................................................ 7/5 Siemens Industry Training .................................................... 7/2 Siemens Service Option for SIMATIC PC / PG ................... 7/17 Siemens Solution Partner Automation .................................. 7/7 SIMATIC 505....................................................................... 2/89 SIMATIC B.Data.................................................................. 4/52 SIMATIC BATCH for WinCC.............................................. 4/108 SIMATIC Flat Panel PRO .................................................... 3/12 SIMATIC Flat Panels ......................................................... 5/130 SIMATIC HMI accessories.................................................. 2/96 SIMATIC HMI IPC477C....................................................... 5/63 SIMATIC HMI IPC477C bundles....................................... 5/110 SIMATIC HMI IPC477C PRO ................................................ 3/7 SIMATIC HMI IPC577C....................................................... 5/67 SIMATIC HMI IPC677C....................................................... 5/71 SIMATIC HMI IPC677C INOX ............................................. 3/22 SIMATIC HMI KP8/KP8F/32F ................................................ 2/6 SIMATIC HMI Net Panel ..................................................... 6/14 SIMATIC HMI operator control and monitoring systems .............................................................. 1/2 SIMATIC HMI Panel PC Ex ................................................. 3/26 SIMATIC HMI Thin Client Ex ............................................... 3/30 SIMATIC Industrial Flat Panel ........................................... 5/120 SIMATIC Industrial Flat Panel MT ..................................... 5/117 SIMATIC Industrial PC .......................................................... 5/2 SIMATIC Industrial Thin Client .......................................... 5/139 SIMATIC Information Server ............................................. 4/110 SIMATIC IPC BIOS Manager ............................................ 5/166 SIMATIC IPC CompactFlash ............................................ 5/155 SIMATIC IPC DiagMonitor ................................................ 5/164 SIMATIC IPC Image & Partition Creator ........................... 5/163 SIMATIC IPC Remote Manager ........................................ 5/165 SIMATIC IPC227D .............................................................. 5/30 SIMATIC IPC227D bundles .............................................. 5/102 SIMATIC IPC277D .............................................................. 5/53 SIMATIC IPC277D bundles .............................................. 5/108 SIMATIC IPC427C .............................................................. 5/39 SIMATIC IPC427C bundles .............................................. 5/104 SIMATIC IPC427D .............................................................. 5/36 SIMATIC IPC427D bundles .............................................. 5/103 SIMATIC IPC477D .............................................................. 5/58 SIMATIC IPC477D bundles .............................................. 5/109 SIMATIC IPC547D ................................................................ 5/7 SIMATIC IPC627C .............................................................. 5/44 SIMATIC IPC647C .............................................................. 5/13 SIMATIC IPC827C .............................................................. 5/47 SIMATIC IPC847C .............................................................. 5/20 SIMATIC KNX/EIB2S7......................................................... 6/22 SIMATIC Logon ....................................................... 4/37, 4/111 SIMATIC Logon for WinCC flexible..................................... 4/76 SIMATIC Maintenance Station .......................................... 4/112 SIMATIC Mobile Panel 177 ................................................. 2/45 SIMATIC Mobile Panel 277 ................................................. 2/52 SIMATIC Mobile Panel 277(F) IWLAN ................................ 2/57 SIMATIC mobile panel accessories ................................... 2/99 SIMATIC MP 377 PRO .......................................................... 3/4 SIMATIC Panel PC .............................................................. 5/50 SIMATIC Panel PC Remote Kit ......................................... 5/161 SIMATIC PC keyboard...................................................... 5/167 SIMATIC PC-based Automation ........................................... 1/8 SIMATIC PC-based controllers........................................... 5/76 SIMATIC powerrate ............................................................ 4/56 SIMATIC ProAgent............................................................ 4/161 SIMATIC ProAgent process diagnostics software............ 4/161 SIMATIC Process Historian............................................... 4/115 SIMATIC S5 ........................................................................ 2/87 SIMATIC S7 ............................................................... 2/77, 2/84 SIMATIC Thin Client.......................................................... 5/143 SIMATIC Thin Client PRO ................................................... 3/14 SIMATIC WinAC ODK ......................................................... 5/90 SIMATIC WinAC RTX .......................................................... 5/77 SIMATIC WinAC RTX F ....................................................... 5/84 SIMATIC WinCC ................................................................. 4/88 SIMATIC WinCC (TIA Portal) Engineering ............................ 4/6 SIMATIC WinCC (TIA Portal) options.................................. 4/31 SIMATIC WinCC (TIA Portal) Runtime ................................ 4/12 SIMATIC WinCC flexible ES................................................ 4/60 SIMATIC WinCC flexible HMI system ................................. 4/59 SIMATIC WinCC flexible options ........................................ 4/71 SIMATIC WinCC flexible RT................................................ 4/64 SIMATIC WinCC Open Architecture ................................. 4/146 Siemens ST 80 / ST PC · 2013 7/23 7 © Siemens AG 2013 Appendix Index S (continued) W SIMATIC WinCC Open Architecture Add-ons .................. 4/155 SIMATIC WinCC options................................................... 4/107 SINEMA server ................................................................. 5/207 SIPLUS Basic Panels.......................................................... 2/24 SIPLUS Comfort Panels...................................................... 2/40 SIPLUS connection boxes.................................................. 2/73 SITOP power supplies...................................................... 5/170 SITOP UPS500P ............................................................... 5/178 SITOP UPS500S ............................................................... 5/177 SNMP OPC server ............................................................ 5/206 Social Media, Mobile Media ............................................... 7/11 SOFTNET for Industrial Ethernet ...................................... 5/196 SOFTNET for PROFIBUS .................................................. 5/227 SOFTNET PN IO ............................................................... 5/199 SOFTNET-IE RNA ............................................................. 5/198 Software for energy management ...................................... 4/51 Software Licenses .............................................................. 7/19 Software packages for SIMATIC IPC and S7-mEC .......... 5/114 Solar systems ..................................................................... 6/28 Standards and approvals ..................................................... 7/4 System components........................................................... 2/69 System components for Mobile Panels .............................. 2/69 System interfaces with WinCC (TIA Portal) ........................ 2/76 System interfaces with WinCC flexible ............................... 2/83 WinCC add-ons and partner management ...................... 4/144 WinCC Audit ....................................................................... 4/36 WinCC Competence Centers ............................................... 7/6 WinCC ControlDevelopment .............................................. 4/50 WinCC DataMonitor............................................................ 4/47 WinCC flexible /Archives .................................................... 4/73 WinCC flexible /Audit.......................................................... 4/75 WinCC flexible /ChangeControl.......................................... 4/72 WinCC flexible /OPC server ............................................... 4/85 WinCC flexible /ProAgent ................................................... 4/87 WinCC flexible /Recipes..................................................... 4/74 WinCC flexible /Sm@rtAccess............................................ 4/78 WinCC flexible /Sm@rtService............................................ 4/82 WinCC Logging .................................................................. 4/34 WinCC Recipes .................................................................. 4/32 WinCC Runtime Advanced................................................. 4/13 WinCC Runtime Communication ........................................ 4/25 WinCC Runtime Professional.............................................. 4/19 WinCC Server / WinCC Client............................................. 4/42 WinCC Sm@rtServer........................................................... 4/38 WinCC WebNavigator ........................................................ 4/44 WinCC/Calendar Scheduler ............................................. 4/116 WinCC/Central Archive Server (CAS)............................... 4/117 WinCC/ChangeControl & WinCC/Audit ............................ 4/118 WinCC/Connectivity Pack & WinCC/Connectivity Station.............................................. 4/120 WinCC/DataMonitor.......................................................... 4/122 WinCC/DowntimeMonitor ................................................. 4/124 WinCC/Event Notifier ........................................................ 4/126 WinCC/IndustrialDataBridge ............................................ 4/127 WinCC/IndustrialX ............................................................ 4/129 WinCC/Open Development Kit (ODK).............................. 4/130 WinCC/ProAgent .............................................................. 4/131 WinCC/Redundancy......................................................... 4/132 WinCC/Server ................................................................... 4/133 WinCC/TeleControl ........................................................... 4/134 WinCC/User Archives....................................................... 4/138 WinCC/Web Navigator ..................................................... 4/139 Wind farms ......................................................................... 6/29 T Terminal boxes ................................................................... Touch pen and touch stylus ............................................... Transponder ....................................................................... Turnkey products................................................................ 2/70 2/98 2/75 6/17 U USB interfaces ................................................................... 3/20 Y Your machines and plant can do more – with Industry Services ..................................................... 7/12 7 7/24 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Appendix Order No. Index 2XV9 6AV6 (Fortsetzung) 2XV9450 .................................................................. 4/105, 6/25 6AV6645 .............................. 2/51, 2/56, 2/67, 2/98, 2/129, 6/34 6AV6646 ................................................ 3/15, 5/142, 5/144, 6/9 6AV6647 ...................................................................... 2/21, 6/8 6AV6651 .................................................................... 2/21, 2/67 6AV6653 .................................................................. 3/15, 5/144 6AV6671 ............................... 2/51, 2/56, 2/72, 2/73, 2/75, 2/97, .............................................. 2/100, 2/108, 2/117, 2/121, 2/123, ............................. 2/129, 2/134, 2/136, 2/138, 5/55, 5/144, 6/34 6AV6675 ........................................................................... 2/121 6AV6691 .............................. 2/51, 2/56, 2/67, 4/63, 4/69, 4/165 6AG1 6AG1124 6AG1500 6AG1647 6AG1671 6AG1931 6AG1972 ............................................................................ 2/43 .......................................................................... 2/109 ............................................................................ 2/25 ............................................................................ 2/73 ............................................................... 5/181, 5/182 ............................................................... 2/109, 5/181 6AG4 6AG4070 6AG4104 6AG4112 6AG4114 6AG4140 ............................................................................ 5/42 ................................................................... 5/10, 5/11 ................................................................... 5/17, 5/18 ................................................................... 5/22, 5/23 ............................................................................ 5/37 6AR1 6AR1403 .......................................... 5/148, 5/150, 5/150, 5/152 6AR1405 ................................................................ 5/148, 5/149 6AV2 6AV2107 ........................................ 4/18, 4/23, 4/24, 4/33, 4/35, ................................................ 4/36, 4/41, 4/43, 4/46, 4/49, 4/50 6AV2114 ........................................................................... 5/115 6AV2115 ........................................................................... 5/115 6AV2124 ....................................... 2/36, 2/129, 5/55, 5/128, 6/8 6AV2132 ............................................................................. 2/21 6AV2181 ............................................ 2/36, 2/117, 2/121, 2/133 6AV3 6AV3672 ........................................................................... 2/129 6AV3678 ........................................................................... 2/121 6AV3688 ............................................................. 2/10, 3/18, 6/8 6AV6 6AV6351 ................................................................ 4/152, 4/153 6AV6352 ............................... 4/153, 4/154, 4/158, 4/159, 4/160 6AV6361 ................................................................ 4/110, 4/115 6AV6371 .............................. 4/101, 4/102, 4/117, 4/119, 4/121, .............................................. 4/123, 4/128, 4/129, 4/130, 4/131, .................................... 4/132, 4/133, 4/138, 4/142, 4/143, 4/165 6AV6372 ................................... 4/55, 4/58, 4/116, 4/125, 4/126 6AV6381 ................................................................ 4/101, 4/102 6AV6382 ........................................................................... 5/115 6AV6574 .................... 2/102, 2/117, 2/121, 2/123, 2/129, 2/136 6AV6610 .................................................................... 4/62, 4/63 6AV6611 .................................................................... 4/62, 4/63 6AV6612 ........................................................... 4/10, 4/62, 4/63 6AV6613 ........................................................... 4/10, 4/62, 4/63 6AV6618 ... 4/69, 4/73, 4/74, 4/75, 4/81, 4/84, 4/86, 4/87, 4/165 6AV6623 ........................................................................... 5/115 6AV6642 ...................................................................... 6/8, 6/43 6AV6643 .................................................... 6/8, 6/23, 6/43, 6/45 6AV6644 ............................................. 3/6, 6/8, 6/43, 6/45, 6/51 6AV7 6AV7200 .................................................................... 3/28, 3/31 6AV7240 .................................................................... 5/60, 5/61 6AV7426 ............................................................................. 6/16 6AV7461 ............................................................................. 6/38 6AV7466 ................................................................ 5/119, 5/137 6AV7476 ............................................................................. 6/47 6AV7486 ............................................................................. 6/47 6AV7671 ............... 5/65, 5/69, 5/74, 5/113, 5/128, 5/132, 5/161 6AV7672 ............................. 2/98, 2/129, 3/24, 5/55, 5/65, 5/69, ................................................. 5/74, 5/113, 5/128, 5/132, 5/155 6AV7674 ......................................... 3/16, 3/17, 3/18, 3/19, 3/20 6AV7675 .................................................................... 3/28, 3/31 6AV7860 ..................................................... 5/128, 5/132, 5/137 6AV7861 ........................................................... 3/13, 5/132, 6/9 6AV7862 ........................................................................... 5/137 6AV7863 ........................................................................... 5/128 6AV7872 ............................................................................. 6/43 6AV7881 ............................................................................. 5/55 6AV7883 ............................ 3/9, 3/10, 5/64, 5/111, 5/112, 5/113 6AV7884 ................................. 5/64, 5/111, 5/112, 5/113, 5/115 6AV7885 ............................................................................. 5/68 6AV789 ...................................................................... 3/23, 5/73 6AV7890 ............................................................................. 5/74 6AV7891 ............................................................................. 5/74 6AV7892 ............................................................................. 5/74 6AV7893 ............................................................................. 5/74 6AV7894 ............................................................................. 5/74 6AV9 6AV9681 ........................................................................... 4/142 6DL5 6DL5000 ........................................................................... 4/137 6DL5002 ........................................................................... 4/137 6DL5101 ........................................................................... 4/137 6ED1 6ED1056 ........................................................................... 2/117 6EP1 6EP1931 ................................................................ 5/181, 5/182 6EP1935 .......................................... 5/177, 5/182, 5/183, 5/184 Siemens ST 80 / ST PC · 2013 7/25 7 © Siemens AG 2013 Appendix Order No. Index 6ES7 6GK5 6ES7193 ........................................................................... 2/108 6ES7272 ........................................................................... 2/136 6ES7623 ........................................................................... 2/138 6ES7647 ....................................... 5/33, 5/42, 5/45, 5/48, 5/207 6ES7648 ............................. 2/117, 3/24, 5/11, 5/18, 5/26, 5/33, ........................................... 5/42, 5/46, 5/49, 5/74, 5/106, 5/155, ................................... 5/160, 5/159, 5/160, 5/163, 5/164, 5/165, ................................................................................ 5/167, 5/169 6ES7657 ........................................................................... 4/109 6ES7658 ......................................................... 4/37, 4/77, 4/111 6ES7671 ......................................................... 5/82, 5/89, 5/115 6ES7675 ................................................................ 5/105, 5/106 6ES7677 .................................................................. 5/99, 5/100 6ES7806 ............................................................................. 5/90 6ES7820 ........................................................................... 5/204 6ES7840 ........................................................................... 4/114 6ES7900 ............ 3/24, 5/11, 5/18, 5/26, 5/46, 5/49, 5/74, 5/161 6ES7901 ....................................................... 2/109, 2/115, 4/70 6ES7972 ......................................................... 2/109, 4/30, 4/70 6GK5204 6GK5784 6GK5786 6GK5788 6GK5791 6GT2 6GT2190 ........................................................................... 2/103 6GT2600 ........................................................................... 2/103 6XV1 6XV1440 .................................................................. 2/115, 6/34 6XV1830 ............................... 2/115, 5/210, 5/212, 5/214, 5/216 6XV1840 ................................................................ 2/110, 2/111 6XV1870 ................... 2/110, 2/111, 2/115, 5/187, 5/188, 5/190, ..................................................................... 5/191, 5/192, 5/193 6XV1871 ........................................................................... 2/111 A5E 6GF6220 ........................................................................... 5/134 A5E01064980 ..................................................................... 5/26 A5E02396171 ..................................................................... 5/18 A5E31477788 ..................................................................... 2/10 6GK1 C794 6GK1160 ............................................. 5/82, 5/89, 5/106, 5/187 6GK1161 .......................... 4/29, 4/70, 4/103, 4/104, 5/82, 5/89, .......................................................... 5/188, 5/189, 5/191, 5/195 6GK1162 ................................ 4/29, 4/103, 5/192, 5/193, 5/195 6GK1500 .................. 2/109, 5/210, 5/212, 5/214, 5/216, 5/218, .......................................................... 5/220, 5/222, 5/224, 5/226 6GK1551 .................................. 4/30, 4/70, 4/103, 4/105, 5/219 6GK1560 ............................................. 5/82, 5/89, 5/106, 5/209 6GK1561 ........................ 4/30, 4/70, 4/103, 4/104, 4/105, 5/82, ................................................ 5/89, 5/209, 5/211, 5/213, 5/215, ................................................................................ 5/217, 5/221 6GK1562 ........................ 4/30, 4/70, 4/103, 4/104, 4/105, 5/82, ............................................................ 5/89, 5/215, 5/217, 5/223 6GK1571 ............................................. 4/30, 4/70, 4/103, 5/225 C79459 ............................................................................. 5/220 6GF6 7 .................................................... 5/187, 5/188, 5/198 ............................................................... 2/102, 2/103 ............................................................... 2/102, 2/103 ............................................................... 2/102, 2/103 .......................................................................... 2/103 6GK1704 .................... 4/29, 4/103, 5/104, 5/189, 5/190, 5/197, ................................... 5/200, 5/219, 5/220, 5/221, 5/222, 5/223, ............................................... 5/224, 5/225, 5/226, 5/227, 5/228 6GK1706 ........ 5/190, 5/197, 5/202, 5/204, 5/205, 5/206, 5/230 6GK1711 .......................................................................... 5/198 6GK1713 ...................... 4/30, 4/70, 4/104, 4/105, 5/210, 5/211, ................................... 5/212, 5/213, 5/214, 5/215, 5/216, 5/217, ........................................................................................... 5/218 6GK1716 ...................... 4/29, 4/70, 4/103, 4/104, 4/105, 5/191, ..................................................................... 5/192, 5/193, 5/195 6GK1781 .......................................................................... 5/207 6GK1901 ............................................................... 2/110, 2/111 6GK1905 ......................................... 5/210, 5/212, 5/214, 5/216 6GK1975 .......................................................................... 2/109 7/26 Siemens ST 80 / ST PC · 2013 W790 W79084 ............................................................................ 2/138 © Siemens AG 2013 Appendix Length key for connecting cables ■ Length key for connecting cables On connecting cables whose length is freely selectable according to the following lists, the blanks (…) in the order no. must be completed in accordance with the length codes given. Length of the connecting cable = Multiplier x length key The different length keys must be taken into account here! Other lengths on request. Multiplier Order no. supplement of the connecting cable 6XV7 777-77777 • 0.01 m E • 0.1 m H • 1.0 m N • 10.0 m T • 100.0 m U Length digit • 10 10 • 12 12 • 15 15 • 16 16 • 20 20 • 25 25 • 32 32 • 40 40 • 50 50 • 60 60 • 63 63 • 80 80 Ordering example: The 6XV1 404-0A… connecting cable must be 16 m long. Multiplier 1.0 m (N) x length digit 16 (16) gives a length of 16 m. The order no. supplement is N16. This is entered in the blank spaces of the order no. The complete order no. for the 16 m long connecting cable is then 6XV1 404-0AN16. 7 Siemens ST 80 / ST PC · 2013 7/27 © Siemens AG 2013 Appendix Catalog improvement suggestions Fax form ■ To Your address Siemens AG I IA AS S ID 2 ST 80 / ST PC 2013 / Ms. Beyer Gleiwitzer Str. 555 90475 Nürnberg Name Fax: +49 (911) 895-153114 Job E-mail: barbara.beyer@siemens.com Company/Department Street/No. Postal code/City Tel. No./Fax E-mail address ■ Your opinion is important to us! Our catalog should be an important and frequently used document. For this reason we are continuously endeavoring to improve it. A small request on our part to you: Please take time to fill in the following form and fax it to us. Thank You! ■ We invite you to grade our catalog on a point system from 1 (= good) to 6 (= poor): Do the contents of the catalog live up to your expectations? Do the technical details meet your expectations? Is the information easy to find? How would you assess the graphics and tables? Can the texts be readily understood? ■ Did you find any printing errors? 7 7/28 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Appendix Notes 7 Siemens ST 80 / ST PC · 2013 7/29 © Siemens AG 2013 Appendix Notes 7 7/30 Siemens ST 80 / ST PC · 2013 © Siemens AG 2013 Appendix Notes 7 Siemens ST 80 / ST PC · 2013 7/31 © Siemens AG 2013 Appendix Conditions of sale and delivery ■ 1. General Provisions By using this catalog you can acquire hardware and software products described therein from Siemens AG subject to the following Terms and Conditions of Sale and Delivery (hereinafter referred to as "T&C"). Please note that the scope, the quality and the conditions for supplies and services, including software products, by any Siemens entity having a registered office outside Germany, shall be subject exclusively to the General Terms and Conditions of the respective Siemens entity. The following T&C apply exclusively for orders placed with Siemens Aktiengesellschaft, Germany. 1.1 For customers with a seat or registered office in Germany For customers with a seat or registered office in Germany, the following applies subordinate to the T&C: • the "General Terms of Payment"1) and, • for software products, the "General License Conditions for Software Products for Automation and Drives for Customers with a Seat or Registered Office in Germany"1) and, • for other supplies and services, the "General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry"1). 1.2 For customers with a seat or registered office outside Germany For customers with a seat or registered office outside Germany, the following applies subordinate to the T&C: • the "General Terms of Payment"1) and, • for software products, the "General License Conditions for Software Products for Automation and Drives for Customers with a Seat or Registered Office outside of Germany"1) and • for other supplies and/or services, the "General Conditions for Supplies of Siemens Industry for Customers with a Seat or Registered Office outside of Germany"1). ■ 2. Prices 7 The prices are in € (Euro) ex point of delivery, exclusive of packaging. The sales tax (value added tax) is not included in the prices. It shall be charged separately at the respective rate according to the applicable statutory legal regulations. Prices are subject to change without prior notice. We will charget the prices valid at the time of delivery. To compensate for variations in the price of raw materials (e.g. silver, copper, aluminum, lead, gold, dysprosium and neodym), surcharges are calculated on a daily basis using the so-called metal factor for products containing these raw materials. A surcharge for the respective raw material is calculated as a supplement to the price of a product if the basic official price of the raw material in question is exceeded. The metal factor of a product indicates the basic official price (for those raw materials concerned) as of which the surcharges on the price of the product are applied, and with what method of calculation. An exact explanation of the metal factor can be downloaded at: www.siemens.com/automation/salesmaterial-as/catalog/en/ terms_of_trade_en.pdf To calculate the surcharge (except in the cases of dysprosium and neodym), the official price from the day prior to that on which the order was received or the release order was effected is used. To calculate the surcharge applicable to dysprosium and neodym ("rare earths"), the corresponding three-month basic average price in the quarter prior to that in which the order was received or the release order was effected is used with a onemonth buffer (details on the calculation can be found in the explanation of the metal factor). 7/32 Siemens ST 80 / ST PC · 2013 ■ 3. Additional Terms and Conditions The dimensions are in mm. In Germany, according to the German law on units in measuring technology, data in inches apply only to devices for export. Illustrations are not binding. Insofar as there are no remarks on the individual pages of this catalog - especially with regard to data, dimensions and weights given - these are subject to change without prior notice. ■ 4. Export regulations We shall not be obligated to fulfill any agreement if such fulfillment is prevented by any impediments arising out of national or international foreign trade or customs requirements or any embargoes and/or other sanctions. Export of goods listed in this catalog may be subject to licensing requirements. We will indicate in the delivery details whether licenses are required under German, European and US export lists. Goods labeled with "AL" not equal to "N" are subject to European or German export authorization when being exported out of the EU. Goods labeled with "ECCN" not equal to "N" are subject to US re-export authorization. The export indications can be viewed in advance in the description of the respective goods on the Industry Mall, our online catalog system. Only the export labels "AL" and "ECCN" indicated on order confirmations, delivery notes and invoices are authoritative. Even without a label, or with label "AL:N" or "ECCN:N", authorization may be required i .a. due to the final disposition and intended use of goods. If you transfer goods (hardware and/or software and/or technology as well as corresponding documentation, regardless of the mode of provision) delivered by us or works and services (including all kinds of technical support) performed by us to a third party worldwide, you must comply with all applicable national and international (re-)export control regulations. If required for the purpose of conducting export control checks, you (upon request by us) shall promptly provide us with all information pertaining to the particular end customer, final disposition and intended use of goods delivered by us respectively works and services provided by us, as well as to any export control restrictions existing in this relation. The products listed in this catalog may be subject to European/German and/or US export regulations. Any export requiring approval is therefore subject to authorization by the relevant authorities. Errors excepted and subject to change without prior notice. 1) The text of the Terms and Conditions of Siemens AG can be downloaded at www.siemens.com/automation/salesmaterial-as/catalog/en/ terms_of_trade_en.pdf © Siemens AG 2013 Catalogs Industry Automation, Drive Technologies and Low-Voltage Power Distribution Further information can be obtained from our branch offices listed at www.siemens.com/automation/partner System Solutions Interactive Catalog on DVD Catalog Low-Voltage Power Distribution and Electrical Installation Technology Catalog Products for Automation and Drives and Low Voltage Power Distribution CA 01 SENTRON Protection, Switching, Measuring and Monitoring Devices SIVACON · ALPHA Switchboards and Distribution Systems Standards-Compliant Components for Photovoltaic Plants 3WT Air Circuit Breakers up to 4000 A 3VT Molded Case Circuit Breakers up to 1600 A Digital: SIVACON System Cubicles, System Lighting and System Air-Conditioning Digital: ALPHA Distribution Systems ALPHA FIX Terminal Blocks SIVACON S4 Power Distribution Boards SIVACON 8PS Busbar Trunking Systems LV 10.1 Building Control GAMMA Building Control Drive Systems SINAMICS G130 Drive Converter Chassis Units SINAMICS G150 Drive Converter Cabinet Units SINAMICS GM150, SINAMICS SM150 Medium-Voltage Converters ROBICON Perfect Harmony Medium-Voltage Air-Cooled Drives Germany Edition Digital: SINAMICS G180 Converters – Compact Units, Cabinet Systems, Cabinet Units Air-Cooled and Liquid-Cooled SINAMICS S120 Chassis Format Units and Cabinet Modules SINAMICS S150 Converter Cabinet Units SINAMICS DCM Converter Units SINAMICS DCM Cabinet SINAMICS and Motors for Single-Axis Drives Three-Phase Induction Motors SIMOTICS HV, SIMOTICS TN • Series H-compact • Series H-compact PLUS Asynchronous Motors Standardline Synchronous Motors with Permanent-Magnet Technology, HT-direct DC Motors SIMOREG DC MASTER 6RA70 Digital Chassis Converters SIMOREG K 6RA22 Analog Chassis Converters Digital: SIMOREG DC MASTER 6RM70 Digital Converter Cabinet Units SIMOVERT PM Modular Converter Systems SIEMOSYN Motors MICROMASTER 420/430/440 Inverters MICROMASTER 411/COMBIMASTER 411 SIMOVERT MASTERDRIVES Vector Control SIMOVERT MASTERDRIVES Motion Control Synchronous and asynchronous servomotors for SIMOVERT MASTERDRIVES SIMODRIVE 611 universal and POSMO ET G1 D 11 D 12 D 15.1 D 18.1 D 21.3 D 23.1 D 23.2 D 31 D 84.1 D 86.1 D 86.2 DA 12 DA 21.1 DA 21.2 DA 22 DA 45 DA 48 DA 51.2 DA 51.3 DA 65.10 DA 65.11 DA 65.3 Low-Voltage Three-Phase-Motors SIMOTICS Low-Voltage Motors MOTOX Geared Motors SIMOGEAR Geared Motors SIMOGEAR Gearboxes with adapter D 81.1 D 87.1 MD 50.1 MD 50.11 Mechanical Driving Machines FLENDER Standard Couplings FLENDER High Performance Couplings FLENDER SIG Standard industrial gear unit FLENDER SIP Standard industrial planetary gear units MD 10.1 MD 10.2 MD 30.1 MD 31.1 Digital: These catalogs are only available as a PDF and/or as an e-book. LV 11 LV 35 LV 36 LV 50 LV 51 LV 52 LV 56 LV 70 NC 60 NC 61 NC 62 NC 81.1 NC 82 PM 21 CR 1 Power Supply and System Cabling Power supply SITOP KT 10.1 Safety Integrated Safety Technology for Factory Automation SI 10 SIMATIC HMI/PC-based Automation Human Machine Interface Systems/ PC-based Automation ST 80/ ST PC SIMATIC Ident Industrial Identification Systems ID 10 DA 65.4 Note: Additional catalogs on SIMODRIVE or SINAMICS drive systems and SIMOTICS motors with SINUMERIK and SIMOTION can be found under Motion Control Process Instrumentation and Analytics Field Instruments for Process Automation Digital: SIPART Controllers and Software Products for Weighing Technology Digital: Process Analytical Instruments Digital: Process Analytics, Components for the System Integration Motion Control SINUMERIK & SIMODRIVE Automation Systems for Machine Tools SINUMERIK & SINAMICS Equipment for Machine Tools SINUMERIK 840D sl Type 1B Equipment for Machine Tools SINUMERIK 808D, SINAMICS V60 and G120, SIMOTICS 1FL5 and 1LE1 SINUMERIK 828D BASIC T/BASIC M, SINAMICS S120 Combi, 1FK7 and 1PH8 motors SIMOTION, SINAMICS S120 & SIMOTICS Equipment for Production Machines Drive and Control Components for Cranes LV 10.2 FI 01 MP 31 WT 10 PA 01 PA 11 SIMATIC Industrial Automation Systems Products for Totally Integrated Automation SIMATIC PCS 7 Process Control System Add-ons for the SIMATIC PCS 7 Process Control System Digital: Migration solutions with the SIMATIC PCS 7 Process Control System SIMATIC NET Industrial Communication ST 70 ST PCS 7 ST PCS 7.1 ST PCS 7.2 IK PI SINVERT Photovoltaics Inverters and Components for Photovoltaic Installations RE 10 SIRIUS Industrial Controls SIRIUS Industrial Controls IC 10 Information and Download Center PDF versions of the catalogs are available on the Internet at: www.siemens.com/industry/infocenter There you’ll find additional catalogs in other languages. Please note the section “Downloading catalogs” on page “Online services” in the appendix of this catalog. © Siemens AG 2013 Siemens AG Industry Sector Industrial Automation Systems Postfach 48 48 90026 NÜRNBERG GERMANY Subject to change without prior notice Order No. E86060-K4680-A101-C1-7600 MQ.R0.R1.0000.04.3.01 / Dispo 07900 KG 0813 3. AUM 672 En / IWI TSTE Printed in Germany © Siemens AG 2013 The information provided in this catalog contains descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. Availability and technical specifications are subject to change without notice. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners. www.siemens.com/automation SO_Umschlag_KG_ST80_STPC_2013_en.indd 2 05.08.2013 13:48:18
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : I IA AS S ID 2 Create Date : 2013:08:05 13:49:35+02:00 Keywords : E86060-D4001-A510-D2-7600 Modify Date : 2013:10:25 13:48:11+02:00 Has XFA : No Language : en XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Producer : Acrobat Distiller 9.5.5 (Windows) Creator Tool : PScript5.dll Version 5.2.2 Metadata Date : 2013:10:25 13:48:11+02:00 Format : application/pdf Description : Catalog Title : SIMATIC HMI / PC-based Automation Operator Control and Monitoring Systems Creator : I IA AS S ID 2, I IA CC PRI Subject : E86060-D4001-A510-D2-7600 Rights : © Siemens AG 2013 Document ID : uuid:3d8d011a-8af9-4647-9fae-49e208bdda84 Instance ID : uuid:4ae5b097-81b6-4bf3-8213-85f507566bfe Marked : True Startup Profile : Print Page Layout : SinglePage Page Mode : UseOutlines Page Count : 676 Signing Date : 2013:10:25 13:47:56+02:00 Signing Authority : ARE Acrobat Product v8.0 P23 0002337 Annotation Usage Rights : Create, Delete, Modify, Copy, Import, ExportEXIF Metadata provided by EXIF.tools