SIMATIC HMI / PC Based Automation Operator Control And Monitoring Systems 1000471964 Catalog

2016-10-06

: Pdf 1000471964-Catalog 1000471964-Catalog B5 unilog

Open the PDF directly: View PDF PDF.
Page Count: 676

DownloadSIMATIC HMI / PC-based Automation Operator Control And Monitoring Systems  1000471964-Catalog
Open PDF In BrowserView PDF
© Siemens AG 2013

Human Machine Interface Systems/
PC-based Automation
SIMATIC HMI / PC-based Automation

Catalog
ST 80/
ST PC

Edition
2013

Answers for industry.

SO_Umschlag_KG_ST80_STPC_2013_en.indd 3

05.08.2013 13:48:25

© Siemens AG 2013

Related catalogs
SIMATIC
Products for
Totally Integrated Automation

ST 70

E86060-K4670-A101-B4-7600
Industrial Communication
SIMATIC NET

IK PI

E86060-K6710-A101-B7-7600
SITOP
Power supply
SITOP

KT 10.1

E86060-K2410-A111-A9-7600
SITRAIN
Training for Automation and
Industrial Solutions

ITC

Only available in German
E86060-K6850-A101-C3
Products for Automation
and Drives
Interactive Catalog, DVD

E86060-D4001-A510-D2-7600
Mall
Information and Ordering Platform
in the Internet:

www.siemens.com/industrymall

CA 01

© Siemens AG 2013

SIMATIC HMI /
PC-based Automation
Operator Control and
Monitoring Systems

Introduction

1

Operator panels

2

HMI devices for special requirements

3

HMI Software

4

PC-based Automation

5

Customized Automation

6

Appendix

7

Catalog ST 80 / ST PC · 2013

The products and systems described in this
catalog are manufactured/distributed under
application of a certified
quality management
system in accordance
with DIN EN ISO 9001
(Certified Registration
No. 2613-05). The certificate is recognized by all
IQNet countries.

Supersedes:
Catalog ST 80 / ST PC · 2012
Refer to the Industry Mall for current updates
of this catalog:
www.siemens.com/industrymall
The products contained in this
catalog can also be found in the
Interactive Catalog CA 01.
Order No.:
E86060-D4001-A510-D2-7600
Please contact your local Siemens branch.
© Siemens AG 2013

Printed on paper
from sustainably
managed forests and
controlled sources.
www.pefc.org

© Siemens AG 2013

2

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Answers for industry.
Integrated technologies, vertical market expertise and services
for greater productivity, energy efficiency, and flexibility.

The Siemens Industry Sector is the
world's leading supplier of innovative
and environmentally friendly products
and solutions for industrial companies.
End-to-end automation technology and
industrial software, solid market expertise, and technology-based services are
the levers we use to increase our customers’ productivity, efficiency and
flexibility. With a global workforce of
more than 100 000 employees,
the Industry Sector comprises the
Industry Automation, Drive Technologies, and Customer Services divisions,
as well as the Metals Technologies
Business Unit.

We consistently rely on integrated technologies and, thanks to our bundled
portfolio, we can respond more quickly
and flexibly to our customers' wishes.
With our globally unmatched range of
automation technology, industrial
control and drive technology as well
as industrial software, we equip companies with exactly what they need over
their entire value chain – from product
design and development to production,
sales and service. Our industrial customers benefit from our comprehensive
portfolio, which is tailored to their
market and their needs.

Market launch times can be reduced by
up to 50% due to the combination of
powerful automation technology and
intelligent industrial software from
Siemens Industry. At the same time,
the costs for energy or waste water
for a manufacturing company can be
reduced significantly. In this way, we
increase our customers’ competitive
strength and make an important contribution to environmental protection
with our energy-efficient products and
solutions.

Siemens ST 80 / ST PC · 2013

3

© Siemens AG 2013

(53²(QWHUSULVH5HVRXUFH3ODQQLQJ

3/0²3URGXFW/LIHF\FOH0DQDJHPHQW

0DQDJHPHQW/HYHO

‡3URGXFW'HVLJQ
‡3URGXFWLRQ3ODQQLQJDQG6LPXODWLRQ
‡'DWD0DQDJHPHQW

0(6²0DQXIDFWXULQJ([HFXWLRQ6\VWHPV
6,0$7,&,7

2SHUDWLRQV/HYHO

0DLQWHQDQFH
$VVHW0DQDJHPHQW

6,0$7,&3&6
2SHUDWRU6\VWHP

(QHUJ\
0DQDJHPHQW

(QJLQHHULQJ
6WDWLRQ

7,$3RUWDO

&RQWURO/HYHO
6,0$7,&3&6
$XWRPDWLRQ
6\VWHPV

6,180(5,.
&RPSXWHU1XPHULF&RQWURO

6,027,21
0RWLRQ&RQWURO

6,0$7,&1(7
,QGXVWULDO
&RPPXQLFDWLRQ

6,0$7,&&RQWUROOHUV
0RGXODU3&EDVHG

)LHOG/HYHO
352),%863$
3URFHVV,QVWUXPHQWDWLRQ

7RWDOO\
,QWHJUDWHG
$XWRPDWLRQ

6,0$7,&'LVWULEXWHG,2

6,0$7,&,GHQW
,QGXVWULDO,GHQWLÀFDWLRQ

+$57

,2/LQN

Setting standards in
productivity and competitiveness.
Totally Integrated Automation.

4

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

TIA is characterized by its unique continuity.
It provides maximum transparency at all levels
with reduced interfacing requirements – covering
the field level, production control level, up to the
corporate management level. With TIA you also
profit throughout the complete life cycle of your
plant – starting with the initial planning steps
through operation up to modernization, where
we offer a high measure of investment security resulting from continuity in the further development
of our products and from reducing the number of
interfaces to a minimum.

3ODQW(QJLQHHULQJ
&2026

(WKHUQHW

6,0$7,&:LQ&&
6&$'$6\VWHP

The unique continuity is already a defined
characteristic at the development stage of
our products and systems.

,QGXVWULDO(WKHUQHW

6,0$7,&+0,
+XPDQ0DFKLQH,QWHUIDFH

The result: maximum interoperability – covering
the controller, HMI, drives, up to the process
control system. This reduces the complexity of
the automation solution in your plant. You will
experience this, for example, in the engineering
phase of the automation solution in the form of
reduced time requirements and cost, or during
operation using the continuous diagnostics facilities of Totally Integrated Automation for increasing the availability of your plant.

6,5,86,QGXVWULDO&RQWUROV

352),1(7
,QGXVWULDO(WKHUQHW
352),%86
6,1$0,&6'ULYH6\VWHPV

6,7233RZHU6XSSO\

$6,QWHUIDFH
.1;*$00$LQVWDEXV

/RZ9ROWDJH'LVWULEXWLRQ

7RWDOO\
,QWHJUDWHG
3RZHU

6,027,&60RWRUV

Thanks to Totally Integrated Automation, Siemens provides
an integrated basis for the implementation of customized
automation solutions – in all industries from inbound to
outbound.

Siemens ST 80 / ST PC · 2013

5

© Siemens AG 2013

Totally Integrated Power:
Future-proof power supply
from one source.

6

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Software tools, products, systems and
support for integrated electrical
power distribution
Energy Management/
Energy Transparency

Operation &
Monitoring

Load
management

Load curves

Forecast

Maintenance
Substation
Distribution
Maintenance
task

Status
reporting/
failure
management

Protocols

Power
Quality

DATE:

Cost center

EMPLOYEE
COST CENTER
PAY PERIOD BEGINNING
PAY PERIOD ENDING

DATE
SUN

MON

TUE

WED

THUR

FRI

SUN

MON

TUE

WED

THUR

FRI

SAT

SUN

TOTAL

IN
OUT
IN
OUT
OVERTIME

TOTAL HOURS
DATE
SAT

SUN

TOTAL

IN
OUT

U
I
cos o
P
W

IN

Hall 1
Distribution 3

Process/
industrial automation

Products & Systems

Infeed II

Renewables

Medium voltage with
protection technology

Air conditioning system
checkup
Replacing circuit
breaker contacts
Replacing meters

OUT
OVERTIME

TOTAL HOURS

central ON
OFF
local ON
OFF
tripped

Transformer

DATE
SUN

MON

TUE

WED

THUR

FRI

SAT

SUN

TOTAL

IN
OUT
IN
OUT

Building
automation

OVERTIME

TOTAL HOURS

Low voltage with
protection and measuring technology

≤ 110 kV

Planning Software Tools

The power supply system acts like a
“vital artery”, forming the basis for
the reliable and efficient functioning
of all electrically operated building
installations. Electrical power distribution therefore requires integrated
solutions. Our answer:
Totally Integrated Power (TIP).
This includes software tools and
support for planning and configuration
and a complete, optimally aligned
product and system portfolio for
integrated power distribution from
medium-voltage switchgear right to
socket outlets.

Network dimensioning
with SIMARIS design

Space requirements and budget calculation
with SIMARIS project

The power distribution products and
systems can be interfaced to building
or industrial automation systems
(Total Building Solutions or
Totally Integrated Automation) via
communication-capable circuit breakers
and components, allowing the full potential for optimization that an integrated solution offers to be exploited
throughout the project cycle – from
planning right through to installation
and operation.

Visualization of device characteristics
with SIMARIS curves

Get more information:
www.siemens.com/tip
www.siemens.com/simaris
www.siemens.com/specifications

Siemens ST 80 / ST PC · 2013

7

© Siemens AG 2013

8

Siemens ST 80 / ST PC · 2013

1

© Siemens AG 2013

Operator control and
monitoring systems /
PC-based Automation
1/2
1/2
1/8

Introduction
SIMATIC HMI operator control and
monitoring systems
SIMATIC PC-based Automation

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Introduction
Gain transparency and lower costs

1

SIMATIC HMI operator control and
monitoring systems

■ Overview
The interface between human and machine –
the human machine interface or HMI for short –
connects the world of automation with the
individual requirements of the operator.
Human machine interfacing is about managing
the process, optimizing machine and system
operation, availability and productivity.

1/2

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Introduction
Gain transparency and lower costs
SIMATIC HMI operator control and
monitoring systems

■ Overview (continued)
Everything from a single source

Integrated into the World Wide Web

With SIMATIC HMI, Siemens Automation and Drives offers a
complete range of innovative and low-cost products and
systems for the multi-faceted tasks of operator control and
monitoring: Ranging from operator panels and visualization
software for operator control and monitoring at the machine
through to SCADA systems for widely differing requirements in
process visualization. For special requirements, optimally
adapted products are offered such as especially rugged HMI
devices with all-round protection for mounting on support arms/
pedestals, or operator panels with stainless steel front for use in
the food and beverages industry. Of course, individual,
customer-specific requirements can also be implemented.

SIMATIC HMI makes the Internet into a control desk - within a
plant as well as in the worldwide network.

Perfectly equipped for integration
in the world of automation
With their open, standardized interfaces in hardware and
software, SIMATIC HMI products can be integrated at any time
in the production and automation level as well as in the company
management level. Connectability to almost every controller on
the market as well as multiple language capability of the configuration and visualization software – including Asian ideographic
languages, of course – facilitate operation worldwide.

Using the WinCC/Web Navigator, you can monitor and operate
plants over the Internet or over the internal corporate intranet.
Thin client solutions can be used to integrate rugged, local
devices which simultaneously establish the connection between
the automation level and the control center. And over a wireless
LAN or cell phone connection, you can use mobile thin clients
such as laptop computers, PDAs (personal digital assistants) or
WebPads.
In this way, process, service or management information can be
made individually available to users. At the machine level, many
control units support remote operation, e.g. as a link between
the automation level and the control room through to service and
diagnostics over the Internet.
For operation and monitoring at the machine, concepts with socalled Sm@rtClients and servers facilitate plant-wide access to
variables and graphics, distributed operator stations as well as
remote operation and diagnostics via the Internet – also in
conjunction with SIMATIC Panels.
www.siemens.com/simatic-hmi

Increased production transparency
through Plant Intelligence
Plant Intelligence is based on the intelligent utilization of information to improve processes within the company.
It is designed to lower plant costs, consolidate and improve
quality, avoid wastage, utilize production facilities better and
ultimately ensure greater efficiency and cost effectiveness within
the company. WinCC provides the best requirements for
achieving this since WinCC features an integrated Historian for
acquiring important production data.
Using intelligent functions and tools, this process data can be
edited into information necessary for making decisions and can
be made available throughout the company whenever and
wherever it is required – for operators as well as production
managers or anyone else within the company.
Even the WinCC basic system provides a wealth of display and
evaluation functions, such as the statistics function for the
message and measured value logs. WinCC options for IT &
business integration make additional "smart" tools available for
optimizing production using Plant Intelligence.

Siemens ST 80 / ST PC · 2013

1/3

1

© Siemens AG 2013

Introduction
Gain transparency and lower costs

1

SIMATIC HMI operator control and
monitoring systems

■ Overview (continued)
Traceability and easy validation

More than just operator control and monitoring

SIMATIC HMI software with "FDA options" provides a high
degree of support to machine and plant manufacturers who
must fulfill high quality requirements, both with respect to the
products to be manufactured as well as to the manufacturing
processes themselves.

The Multi Panels under Windows CE combine the advantages of
two worlds: On the one hand, the ruggedness of an operator
panel and on the other hand the flexibility typical of a PC.

These options simplify plant validation enormously and thus
provide the most convincing and comprehensive solution for the
requirements of these industries.
They support the user in fulfilling high quality requirements as
specified by the FDA (Food and Drug Administration) 21 CFR
Part 11 for the food, beverages and pharmaceutical industries.
Increased plant availability
All operator panels and Panel PCs are designed for harsh industrial use. Redundant process visualization systems ensure a
high degree of plant availability during normal operation.
Distributed operator control concepts
SIMATIC HMI offers different solutions for different requirements
for operator control of large machines and plants spread over
extensive areas.
Thus, the Sm@rtAccess option of the SIMATIC WinCC flexible
visualization software, for example, allows HMI devices such as
panels, Thin Clients and PCs plant-wide access via PROFINET/
Ethernet to current process values and the local screen images
of all involved stations.
SIMATIC HMI software offers appropriate options for
diagnostics, maintenance and telecontrol over the Internet from
local operator stations.
As remote operator stations, SIMATIC Thin Clients make the
functionality of machine-level panels available in the control
room or in the office, thanks to their connection to PROFINET/
Ethernet, and in the other direction, they bring SIMATIC WinCC
or office or IT functionality straight to the machine.
In PC-based applications, a SIMATIC Flat Panel monitor can take
over the function of the operating unit from PCs, such as
SIMATIC Rack or Box PC, at a distance of up to 30 m.

1/4

Siemens ST 80 / ST PC · 2013

Apart from classical operator control and monitoring, other
automation functions such as control functions can execute
simultaneously. And for PC-based automation, the SIMATIC
Panel PCs are available as a compact automation platform - the
embedded versions being especially compact and rugged as
well as maintenance-free.

© Siemens AG 2013

Introduction
Gain transparency and lower costs
SIMATIC HMI operator control and
monitoring systems

■ Overview (continued)
All the advantages of Totally Integrated Automation

Investment protection is included

With Totally Integrated Automation (TIA), Siemens is the only
supplier who offers a system-wide, integrated product and
system range for automating the complete production workflow.
The distinguishing feature of TIA is that it is completely
integrated. The reduced number of interfaces results in very
clear structures.

Our many years of experience in the automation engineering
sector are to your advantage. The same applies to our global
service network with its expert support.
Further services, such as a software update service, training,
ordering over the Internet, etc. round off what we have to offer.

This reduces time and costs required for engineering the
automation solution and increases the availability of the plant.
In conjunction with other SIMATIC components, SIMATIC HMI
also supports system diagnostics and process diagnostics
during normal operation. You can start STEP 7 diagnostics
directly from WinCC for comprehensive error diagnostics from
the circuit diagram through to the PLC program.
The SIMATIC Maintenance Station visualizes the maintenance
information for the automation technology of a system – from the
controller and network components to switchgear, protective
equipment and control devices and the drives.
This gives a clear overview of the status of the automation at any
time.
A competent partner for automation solutions
With SIMATIC HMI, you not only get excellent products to suit
your requirements, we will also support you when selecting a
partner for your automation solution. In our worldwide network of
Siemens Automation Solution Partners, you will find competent
contact partners in your area who are always up-to-date with
SIMATIC HMI technology.
The Siemens-internal WinCC Competence Centers implement
technology-specific products as well as customer and industryspecific solutions on the basis of WinCC.
WinCC specialists are external system integrators who combine
their WinCC expertise with their industry and technology knowhow to create tailor-made, cost-effective solutions. Numerous
products from our partners that perfectly interact with WinCC are
available as WinCC Add-ons.

Siemens ST 80 / ST PC · 2013

1/5

1

© Siemens AG 2013

Introduction
A whole world of operator control and monitoring

1

SIMATIC HMI operator control and
monitoring systems

SIMATIC® HMI®
HMI devices
SIMATIC HMI Key Panels
Operator panels with bus capability for easy and direct
operation of machines.
www.siemens.com/key-panels
SIMATIC HMI Basic Panels
Operator panels with basic functionality for low-cost operator
control and monitoring of simple applications.
www.siemens.com/basic-panels

Process
visualization
Single-user PC

SIMATIC HMI Comfort Panels
HMI devices with high-end functionality for demanding
applications.
www.siemens.com/comfort-panels
SIMATIC HMI Mobile Panels
Mobile operator panels with or without cables for direct operator
control of the plant and machine from any location.
www.siemens.com/simatic-mobile-panels
HMI devices for special requirements

Operator control
and monitoring
directly at the
machine

Key Panels

Basic Panels

Fully enclosed HMI devices for SIMATIC
The fully enclosed SIMATIC HMI devices (MP 377 PRO,
HMI IPC477C PRO, Flat Panel PRO and Thin Client PRO) are
ideal for industrial applications in harsh environments due to
their extremely robust design. They are, for example, specially
designed for mounting on a support arm/stand.
www.siemens.com/ip65-hmi-devices
Devices with stainless steel fronts
Panels and Panel PCs with touch screens and stainless steel
fronts are designed for machine-level operator control and
monitoring in the food, beverages and tobacco industry.
www.siemens.com/inox-hmi-devices

SIMOTION
Motion Control

HMI devices for hazardous areas
Intrinsically safe Panel PCs and Thin Clients that were specifically developed for hazardous areas.
www.siemens.com/simatic-hmi-ex
HMI software
Flexibility in any HMI application – from Basic Panels through to
process visualization

Actuators / Sensors

SIMATIC WinCC in the Totally Integrated Automation Portal
(TIA Portal) is part of a new, integrated engineering framework
which offers a uniform engineering environment for
programming and configuration of control, visualization and
drive solutions.
WinCC in the TIA Portal is the software for all HMI applications
ranging from the simplest operation solutions with Basic Panels
to SCADA applications on PC-based multi-user systems.
www.siemens.com/tia-portal
SIMATIC WinCC V7 remains available for extremely complex
applications featuring Plant Intelligence solutions, integrated
archive servers or redundant architectures, whereas WinCC
Open Architecture addresses applications with demanding
customization requirements, also on non-Windows platforms.
www.siemens.com/wincc
WinCC Open Architecture adressiert Anwendungen mit
hohem kundenspezifischen Anpassungsbedarf – auch auf
Nicht-Windows-Plattformen.
www.siemens.com/wincc-open-architecture

1/6

Siemens ST 80 / ST PC · 2013

Customized Automation
With Customized Automation, field-proven SIMATIC,
SIMATIC IPC and SIMATIC HMI standards are transferred to
individual products and systems – tailored precisely to the
customer's requirements. The portfolio covers the hardware and
software range, as well as support and logistics.
www.siemens.com/customized-automation

© Siemens AG 2013

Introduction
A whole world of operator control and monitoring
SIMATIC HMI operator control and
monitoring systems

Enterprise Resource Planning (ERP)

Manufacturing Execution Systems (MES)
Plant Intelligence
Internet client

Client/Server

Panel PCs
Flat Panel monitors

Mobile Panels

SIMATIC Controller

S7-200 S7-1200

Field devices

S7-400

Software HMI
WinCC (TIA Portal)

Thin Clients

Additional automation systems

S7-300

Drives

G_ST80_XX_00365

Comfort Panels

SCADA system WinCC

Siemens ST 80 / ST PC · 2013

1/7

1

© Siemens AG 2013

Introduction

■ Overview
SIMATIC
Thin Client

SIMATIC WinCC
Visualization
Archive
Databases

SIMATIC Field PG
Configuration
Programming
STEP 7

PROFINET
Industrial Ethernet
SIMATIC S7

SIMATIC Panel PC
WinCC, WinAC
Software PLC

SIMATIC Rack PC

SIMATIC Box PC
Nanobox PC/Microbox PC

WinAC (F)
Software PLC

WinAC (F)
Software PLC

SIMATIC Embedded Bundles:
IPC2x7D/IPC4x7C
S7-modular Embedded Controller

PROFINET
PROFIBUS
SIMATIC HMI Panel
Operator control and
monitoring

ET 200

SIMOTION D / SINAMICS / MICROMASTER

G_ST70_XX_00169

1

SIMATIC PC-based Automation

SIMATIlC PC-based Automation

Embedded bundles with industrial PCs

www.siemens.com/pc-based

Embedded bundles based on the embedded industrial PCs are
extremely compact, robust, and maintenance-free systems for
use at machine level. The functions PC-based Control (also failsafe) and/or visualization are already pre-installed and ready to
use.

Industrial PCs
Our reliable and innovative industrial PCs are the optimal PC
hardware platform for PC-based Automation from Siemens.
www.siemens.com/simatic-ipc
PC-based controllers

www.siemens.com/simatic-embedded-bundles
Software packages for SIMATIC IPCs

Siemens has developed a wide range of coordinated hardware
and software components for PC-based Automation. Focal
point: SIMATIC PC-based Control with SIMATIC WinAC, the
open, flexible and reliable software controller for your PC-based
automation solution, also approved by the German Technical
Inspectorate and fail-safe.

SIMATIC industrial PCs are offered with low-cost software
packages. For the runtime versions with the visualization
software products SIMATIC WinCC or WinCC Professional,
WinCC flexible or WinCC Advanced, as well as the software
controller SIMATIC WinAC RTX (F). The simultaneous purchase
of industrial PC and software package results in the price
advantage.

www.siemens.com/winac

www.siemens.com/simatic-ipc-packages

Embedded controllers

Industrial monitors and thin clients

SIMATIC S7-mEC is a modular controller in S7-300 design with
the latest embedded PC technology. It comprises the EC31
(CPU) as well as the optionally available expansion modules.

Flexible distributed operating concepts can be implemented via
Flat Panel monitors and thin clients. These are industry-standard
LCD monitors with high-luminance displays that are placed up
to 30 m away from the PC, or high-performance industrial thin
clients. SIMATIC ITC, for one or even several operator stations,
can be placed as far away as required via Industrial Ethernet.

www.siemens.com/simatic-s7-mec

www.siemens.com/simatic-ifp
www.siemens.com/simatic-itc

1/8

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Introduction
SIMATIC PC-based Automation

■ Overview (continued)
Measurement of foil thickness

Application examples
www.siemens.com/pc-based-applications

During the manufacture of
plastic films, a highly accurate
and uniform foil thickness over
the entire width is a decisive
quality criterion.
For this purpose, a measuring
head with radioactive source
moves back and forth above the
film and perpendicular to the
continuously transported reel,
and a sensor moves underneath
the foil.

Unit-type cogeneration unit
When redesigning unit-type
cogeneration units, the
automation approach should
also be restructured. The
objective was to execute all
control, visualization and
archiving tasks which were
previously handled by a PLC
and a PC on a compact unit.
Space was to be saved in the
control cabinet, and the administration and training requirements reduced. At the same
time a rugged, maintenancefree device was required which can also be easily connected
over the Internet.
The advantages of the solution with SIMATIC PC-based
Automation:
• Microbox PC IPC427C as a rugged, compact embedded
system
- Control, visualization and archiving of the process parameters in one device
- Space and cost savings thanks to integration of several
tasks on a single embedded industrial PC
Previously: one PLC and one visualization PC
• Easy and quick access to the embedded IPC over the Internet

Router

E-mail
SIMATIC HMI IPC577
Remote control
station

2 x ET 200S with
motor starter
2 x ET 200S
DI/DO

The advantages of the solution with SIMATIC PC-based
Automation:
• Visualization is performed using WinCC, and control using
WinAC RTX on a PC.
• Complex mathematical algorithms are required for evaluation
of the extensive measured data.
• These are meaningfully implemented in the high-level
language C++. Seamless and high-performance integration
of these algorithms into the STEP 7 program is via the ODK
(Open Development Kit).
• Data exchange between WinAC RTX and WinCC, for visualization of the extensive measured curves, takes place very
quickly via the hard drive cache. This functionality was also
implemented via the ODK.
• Interconnection of the standardized technology function is via
CFC (Continuous Function Chart).

WinCC

WinAC RTX

Visual C++

CP 5613 A2

Analysis of the
measured data

The plant concept
ET 200M
Drive
PROFIBUS

G_ST80_XX_00431

Embedded IPC
Microbox PC
IPC427

Internet/
telephone network

G_ST80_XX_00430

Industrial
Ethernet

From the attenuation of the radiation, the foil thickness can be
determined exactly at each position by extensive mathematical
calculations, and deviations from the reference thickness can be
compensated.

The plant concept

Siemens ST 80 / ST PC · 2013

1/9

1

© Siemens AG 2013

Introduction

■ Overview (continued)
PC-based control of paint shops for plastic automotive parts
For reasons of quality assurance
and product liability, paint shop
manufacturers are obliged to
use a host computer for
archiving the process data of a
paint shop for flat parts, but this
quickly developed into a PCbased automation system with
control tasks.

The advantages of the solution with SIMATIC PC-based
Automation:
• Performance of the SIMATIC WinAC PC-based control.
• Coupling to Linux servers through an Industrial Ethernet fiberoptic network.
• Open and flexible for expansions.
• Possibility of integration into the existing automation concept.
• Archiving and backup of process data, as well as production
data acquisition.

Linux
Server

FOC Ethernet

Rack PC IPC847
WinAC RTX
WinCC flexible
PROFIBUS DP
HMI
Panel
ET 200M

S7-314

S7-314
HMI Panel
MPI DP

Frequency
converter

TP 177
HMI Panel

The plant concept

1/10

Siemens ST 80 / ST PC · 2013

VS 710

G_ST80_XX_00432

1

SIMATIC PC-based Automation

Innovative PC-based solution with safety for solar panel
production
For a new plant for the
production of solar panels, the
existing highly heterogeneous
concept is to be replaced by a
new, state-of-the-art automation
solution which can cover the
comprehensive demands in a
compact and integrated way.
There are increased performance and memory requirements due to the increased
complexity of the system. The
PLC should also be able to
provide the specified safety functions (emergency stop, access
protection to hazardous areas).
Various bus systems must be linked in plant 3. Also a customerspecific Windows application is to be used on the selected
systems and therefore the connection to a higher-level MES
system has to be implemented.
The system is designed for high throughput and three-shift
operation.
The advantages of the solution with SIMATIC PC-based
Automation:
• Very high performance and available memory with the
SIMATIC Modular Embedded Controller EC31-RTX F. In the
RTX F version (worldwide the first software PLC with safety
functionality), the EC31 offers full coverage of all safety
requirements in the plant. This system is integrated
seamlessly in Totally Integrated Automation and enables
effective, plant-wide engineering.
• Thanks to its openness (Open Development Kit), WinAC RTX
on the host SCADA industrial PC offers the possibility for
integrating a Windows customer application with very little
effort, and is thus used as a data concentrator (process
quality/diagnostic data), and communication with the host
MES system is also implemented in combination with WinCC
(SCADA).
• Industry-standard products from the SIMATIC range offer
maximum quality for 24/7 round the clock operation.

© Siemens AG 2013

Introduction
SIMATIC PC-based Automation

■ Overview (continued)
PC-based machine data acquisition optimizes the production
of farming machinery

Safe transfer at sea
For transferring persons at sea
to wind energy plants or oil
platforms, a Dutch company has
developed a six-legged
platform on hydraulic cylinders.
This platform is basically an
upside-down flight simulator,
and allows safe transfer from a
ship even in bad weather.

To introduce more efficient,
resource-saving and therefore
cost-effective production
processes in the factory, a
leading farming machinery
manufacturer has integrated a
central, plant-wide machine
data acquisition system using
Panel PCs. Due to the need for
retrofitting in the existing
environment, flexible and
space-saving installation of the
Panel PCs was paramount.

A SIMATIC S7 modular embedded controller (S7-mEC) with fast
I/O cards measures the movements of the ship and controls the
extending or retracting of the cylinders so that all movements are
compensated.

More than 200 fully enclosed SIMATIC HMI IPC477C PRO Panel
PCs for central machine data acquisition with communications
interfacing to the production machines and the production
planning computer. Mounting of the Panel PCs directly at the
machine without additional control boxes on stand-alone
columns.

The advantages of the solution with SIMATIC PC-based
Automation:
• Fault-tolerant SIMATIC S7-400H in redundant design for
general control tasks.
• Two lower-level SIMATIC S7 modular embedded controllers
which meet the requirements for high speeds, integration of
fast I/O cards, and a flexible, modular and rugged design.
• An integrated programming environment
with SIMATIC STEP 7.
• Automation products from Siemens comply
with the stringent requirements of the offshore sector.

The advantages of the solution with SIMATIC PC-based
Automation:
• Enhanced efficiency by optimizing the complete production
organization through a high degree of uniformity.
• Minimized use of resources
(less paper is required in production).
• Simple, low-cost retrofitting of the Panel PC directly in
production on a stand, without the installation of an additional
operator console.

Siemens ST 80 / ST PC · 2013

1/11

1

© Siemens AG 2013

Introduction

■ Overview (continued)
PC-based control in automotive test rigs

PC-based control in the semiconductor industry

Test rigs in the automotive
industry require trouble-free
operation and high quality.
A high-performance system is
required in the control,
processing, archiving and
visualization of measured data
which can also provide
openness and flexibility for
connection to different bus
systems and for the use of
software.
The advantages of the solution with SIMATIC PC-based
Automation:
• Flexible, easy-to-service and maintenance-friendly
system with Windows XP Embedded in conjunction with
SIMATIC WinAC.
• Reduction in integration overhead thanks to integral interfaces
such as PROFINET, PROFIBUS, Ethernet, CAN, and the flexibility when using modules for different bus systems,
e.g. PC/104.
• System availability concept ensures round-the-clock
operation and reduced downtime costs.
• Fan-free, temperature-resistant operation up to 50°C saves
additional cooling measures.
• High investment security through long-term availability of the
components.

Touch panel

In the semiconductor industry, high quality and fault-free
operation round-the-clock are decisive criteria. A high-performance system that guarantees fast and precise production of
the semiconductors is required for controlling the machines,
monitoring the production system, and processing the
production data.
High flexibility and openness are also required for connecting to
the production control system and machine engineering system.
The advantages of the solution with SIMATIC PC-based
Automation:
• Compact, rugged industrial PCs with powerful processors
and the latest technology enable high processing performance.
• Pre-installed systems save time and costs when integrated
into the overall system.
• WinCC ToolLink-EDA (equipment data acquisition) enables
diagnostics of process and machine data in real time.
• System availability concept with integral RAID1 functionality
and remote monitoring with SIMATIC PC DiagMonitor ensures
fault-free 24-hour operation.
• High investment security through long-term availability of the
components.
• International certification and worldwide support guarantee
global use.

Touch Panel
Host
Industrial Ethernet

Microbox
PC IPC427

Label printer
Industrial Ethernet

CAN-Bus

Barcode
reader

SIMATIC
IPC627

Vehicle
control unit

Machine
control
Visualization

PROFIBUS DP
Distributed
I/O devices

Distributed
I/O devices

Sensors

Sensors

The plant concept

1/12

Siemens ST 80 / ST PC · 2013

SIMATIC
IPC627

Industrial Ethernet

Port to
engineering
system

HUB

HMI
Panel

The plant concept

Measuring and
control
instruments
Sensors

G_ST80_XX_00434

RS232
USB

G_ST80_XX_00433

1

SIMATIC PC-based Automation

© Siemens AG 2013

Introduction
SIMATIC PC-based Automation

■ Overview (continued)
Track & trace line controller for tobacco industry
In order to comply with new
legal regulations, a track & trace
system in an existing plant has
been extended.
The requirement is to test
100 cartons per minute in
three-shift operation and to save
the data in an SQL database for
traceability reasons.
The automation system should
be characterized by high
ruggedness, but also offer the
openness required to connect
additional components such as printers and the Machine Vision
system.
The advantages of the solution with SIMATIC PC-based
Automation:
• Compact automation solution consisting of embedded
industrial PC Microbox PC IPC427, PLC with preinstalled and
ready-to-use software PLC WinAC RTX, and visualization with
WinCC flexible.
• Control of the entire track & trace system and interfacing to the
control system.
• Open solution with the help of the WinAC ODK (Open Development Kit) thanks to a link to an SQL database for managing
the serial numbers and other data.
• Additional openness and flexibility by connecting printers and
vision system.

Retrofit of a woodworking machine – safe!
In the past, machines and plants
for wood-working were
equipped with specially
developed, proprietary
controllers. Today, futureoriented standard components
are used for retrofit projects. The
customer decided in favor of
integrating standard automation
and safety technology in a
single unit with the SIMATIC
WinAC RTX F software controller
in a fan-free and maintenancefree IPC, the SIMATIC IPC427C
Microbox PC. PROFINET as an innovative fieldbus connects
distributed I/O, safety and operator panels quickly and easily.
The advantages of the solution with SIMATIC PC-based
Automation:
• The compact PC-based automation solution multiplies the
performance and precision of the plant.
• Implementation of PROFINET resulted in a series of additional
advantages such as the diagnostics capability.
• Integration of standard and fail-safe automation in a single unit
achieved component savings. The size of the cabinet was
reduced by 20 percent and the wiring by 50 percent. The
customer benefited from a high level of operating convenience and minimized machine downtimes.
www.siemens.com/reference-video-kuper

Siemens ST 80 / ST PC · 2013

1/13

1

© Siemens AG 2013

Introduction

■ Overview (continued)
Image processing with data backup
In image processing applications, high performance computers
are required due to the large volume of data to be processed.
The image data must be recorded, processed and saved
quickly. Frame grabber cards with a high data throughput, for
example, are used for recording image data. The interfaces for
the expansion cards must not become bottle-necks in this case.
To ensure continued problem-free processing of the acquired
data, you need a state-of-the-art system with up-to-date
processor and memory technology.
Lots of data is produced again during the subsequent data
backup. Thus the available storage medium must be fast and
fail-safe at the same time. An open system is required for
connecting to existing plants.
The advantages of the solution with SIMATIC PC-based
Automation:
• Rugged SIMATIC PC with state-of-the-art processor performance and the latest technology.
• Current interfaces such as PCI Express for applications with a
high data throughput rate, e.g. frame grabber cards for
recording image data.
• Visualization on up to two monitors with an optional,
high-performance graphics card.
• Onboard communication interfaces such as Ethernet and
PROFINET, e.g. for connecting to EPS systems or integration
in existing systems.
• International certifications and global support facilitate the
worldwide use of the image processing solution.

Control room

Server room
Rack PC IPC547
for visualization and
intermediate storage
of data

Flat Panel

Rack PC
IPC547 –
Server for data
management

Industrial Ethernet

Machine-level
Rack PC IPC847 with
PCIe frame grabber cards

Camera

.
.
.
The plant concept

1/14

Siemens ST 80 / ST PC · 2013

High-performance industrial PC for reliable control and
monitoring of wind power plants.
All Siemens turbines for offshore
wind power plants feature
special technical characteristics
that ensure long-term,
low-maintenance operation.
In contrast to sites on land,
offshore wind farms are not
always accessible to service
teams. The basic quality
requirements and standards for
all components used in terms of
absolute fail-safety and
reliability, are therefore
extremely high.
The SIMATIC Box PC of the 627 series that has been implemented matches the requirements of the solution provider all the
way down the line. The rugged industrial PC is designed for
24-hour continuous duty at ambient temperatures up to 55 °C.
For reliable operation, the Box PC is installed in a solid metal
enclosure that is resistant to shock and vibration and that
demonstrates a high degree of of electromagnetic compatibility
(EMC). For a high level of data security, the option of a mirror disk
system with two hard disks (RAID1) was selected. The RAID1
controller is already onboard, and does not occupy a PCI slot.
The rugged, reliable hardware with extremely compact dimensions in durable industrial design also stands up to the demands
of continuous operation in a harsh environment.
The advantages of the solution with SIMATIC PC-based
Automation:
• The mounting dimensions of Box PCs remain identical over
several device generations and mounting solutions can be
simply reused for the next generation.
• Furthermore, when a new device generation is used, any frontaccessible interfaces and function elements can be retained.
For example, the Siemens Wind division already utilized a
complete lifecycle of a Box PC generation and no adjustments
to a new hardware platform were required when the successor
product was introduced.
• Through compliance with international standards, such as CE
and UL, and worldwide service, the Box PC can be implemented round the globe.

G_ST80_XX_00436

1

SIMATIC PC-based Automation

2

© Siemens AG 2013

Operator panels
2/2

Introduction

2/6
2/6

Key Panels
SIMATIC HMI KP8/KP8F/32F

2/12
2/12

Basic Panels
Basic Panels – Standard

2/24

SIPLUS Basic Panels

2/26
2/26

Comfort Panels
Comfort Panels – Standard

2/40

SIPLUS Comfort Panels

2/44
2/45
2/52
2/57
2/69
2/70
2/73
2/74
2/74
2/75

Mobile Panels
SIMATIC Mobile Panel 177
SIMATIC Mobile Panel 277
SIMATIC Mobile Panel 277(F) IWLAN
System components for Mobile Panels
Terminal boxes
SIPLUS connection boxes
System components
Charging station
Transponder

2/76
2/77
2/79

System interfaces with WinCC
(TIA Portal)
SIMATIC S7
Controllers from other manufacturers

2/83
2/84
2/87
2/89
2/90

System interfaces with WinCC flexible
SIMATIC S7
SIMATIC S5
SIMATIC 505
PLCs from other manufacturers

2/96
2/96
2/97
2/98
2/99
2/100
2/101
2/104
2/104
2/105
2/109
2/110
2/112
2/116
2/118
2/122
2/124
2/130
2/135
2/137

SIMATIC HMI accessories
General HMI accessories
Industrial USB Hub 4
Touch pen and touch stylus
SIMATIC Mobile Panel accessories
Power supply unit
Additional accessories
SIMATIC HMI accessories
Connectors/converters/adapters
HMI connecting components
RS485 bus connector
IE FC RJ45 Plug 2 x 2
Connecting cables
Memory media
Service sets
Protective covers
Protective films
Fasteners
Labeling strips
Batteries

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
Introduction
Introduction

■ Overview

Highest demands in terms
of performance and functionality?
Brilliant widescreen displays from 4"... 22"
Innovative commissioning and service concept
Energy management with PROFIenergy

2

Comfort
Panels
Basic
Panels

Low priced, pixel graphics
operator prompting?

Mobile
Panels
Key
Panels

Intuitive operation of
3"... 15"
Integrated HMI basis
functionality
Perfect interaction with
SIMATIC S7-1200

Maximum mobility and
flexibility?
Innovative operation
with and without cable
Robust for site-related local
operation
Integrated safety
concept

Eng
inee

Fast commissioning
Easy networking
Intuitive state detection

red w

ith Tota
lly

tion
Integrated Automa

al
Port

G_ST80_XX_00501

Flexible expansion with keys –
or even safety functions?

A finely graded range of HMI devices is available for local
operator control and monitoring: From Key Panels and Basic
Panels to Comfort Panels and Mobile Panels. HMI devices with
all-round IP65/NEMA 4 protection for distributed configurations
are available for applications with especially high requirements
with regard to ruggedness.

Comfort Panels

Key Panels

The Comfort Panels are equipped with PROFINET/Ethernet as
well as PROFIBUS DP/MPI interfaces.

Key Panels (KP) are the innovative alternative to conventionally
wired operator keypads. Supplied pre-assembled and ready for
installation, the bus-compatible operator panels are the key to
drastically reducing wiring times when compared with conventional methods.
Basic Panels
Basic Panels offer basic HMI functionality for small machines
and applications. They are available in 3" and 4" sizes as a pure
Key Panel (KP), from 4" to 10" with touch screen and additional
keys (KTP), and as a pure Touch Panel (TP) in size 15". Variants
can be selected for connection to PROFINET/Ethernet or
PROFIBUS DP/MPI.

2/2

Siemens ST 80 / ST PC · 2013

Comfort Panels offer high-end functionality for demanding applications. They offer high-resolution widescreen displays in sizes
from 4" to 22", alternatively for touch screen operation (TP) or key
operation (KP). In size 4" also with touch screen and additional
keys (KTP).

Mobile Panels
The portable operator panels facilitate operator control and
monitoring at the actual scene of the event with direct access
and visual contact to the process. They provide simple and safe
reconnection during operation (Mobile Panel 177 and Mobile
Panel 277) or wireless freedom (Mobile Panel 277 (F) IWLAN)
and can therefore be used flexibly on a machine or system.

© Siemens AG 2013

Operator panels
Introduction
Introduction

■ Overview (continued)
Rugged and compact for use at machine level

Open for a wide variety of automation systems

With IP65/NEMA 4 degree of protection at the front, high EMC
and extreme vibration resistance, the SIMATIC HMI operator
panels are ideally suited for use at machine level in rough industrial environments. Thanks to their compact design with a
shallow mounting depth, the stationary HMI devices can be
fitted anywhere, even where only restricted space is available.
For distributed configurations, there are also devices available
with all-round IP65/NEMA 4 protection.

Despite being consistently incorporated into the SIMATIC world,
the Panels are nevertheless open for connection to PLCs from
many different vendors. The standard delivery includes a
comprehensive range of user-friendly drivers.

The extremely rugged and shock-proof enclosure with degree of
protection IP65 makes the Mobile Panels especially suitable for
industrial applications. Their low weight and ergonomic design
means that they are user-friendly and easy to operate.
One configuration software for everything
SIMATIC WinCC (TIA Portal) is a tool for the uniform configuration of all SIMATIC HMI Panels as well as PC-based systems.
Graded variants are available for every task. The software
permits simple and efficient configuration. Programming
experience is not required.
Once created, configurations can be reused within the family.
Component of Totally Integrated Automation
Siemens provides the complete modular system of matched
components for automation solutions from one source and —
with Totally Integrated Automation — one of the most globally
successful automation concepts. SIMATIC WinCC (TIA Portal) is
an integral component of this world. It offers crucial advantages.
Thanks to the triple uniformity in configuration/programming,
data management and communication, automation solution
engineering costs are significantly reduced.

Innovative operator control and monitoring
The SIMATIC HMI Panels facilitate innovative operator control
and monitoring combined with ruggedness, stability and
simplicity. On the Comfort Panels in particular, standard
hardware and software interfaces, e.g. the Multimedia Card/
SD Card, USB, Ethernet, PROFIBUS DP and Visual Basic
scripts, provide more flexibility and openness as well as access
to the office world.
Worldwide application
The SIMATIC HMI Panels are ideally equipped for global use.
Online language switching permits selection of up to
32 languages during operation simply by pressing a button.
The wide variety available also includes, for example, Asian
logographic languages (Chinese, Taiwanese, Korean,
Japanese) or Russian. The configuration interface of WinCC
(TIA Portal) including the online help and the complete
documentation is also multilingual. Up to 32 languages can be
used in one project. And all this is complemented by global
service and support from Siemens.

Siemens ST 80 / ST PC · 2013

2/3

2

© Siemens AG 2013

Operator panels
Introduction
Introduction

■ Overview (continued)
Configuration at a Glance
WinCC (TIA Portal) engineering software
Basic

Comfort

Advanced

Professional

Basic Panels

2

KP300 Basic

•

•

•

•

KTP400 Basic mono PN

•

•

•

•

KTP400/KP400 Basic color PN

• 2)

• 2)

• 2)

• 2)

KTP600 Basic

•

•

•

•

KTP1000 Basic

•

•

•

•

TP1500 Basic

•

•

•

•

Comfort Panels
KTP400/KP400 Comfort

•

•

•

TP700/KP700 Comfort

•

•

•

TP900/KP900 Comfort

•

•

•

TP1200/KP1200 Comfort

•

•

•

TP1500/KP1500 Comfort

• 2)

• 2)

• 2)

TP1900 Comfort

• 2)

• 2)

• 2)

TP2200 Comfort

2)

2)

• 2)

•

•

Mobile Panels
Mobile Panel 177

•

•

•

Mobile Panel 277

•

•

•

Mobile Panel 277(F) IWLAN

• 3)

• 3)

• 3)

Panels – 70 series
OP73

•

•

•

OP77A

•

•

•

OP77B

•

•

•

TP 177A

•

•

•

TP/OP 177B

•

•

•

•

•

•

•

•

•

•

•

•

•

•

•

WinAC MP 177

• 1)

• 1)

• 1)

WinAC MP 277

• 1)

• 1)

• 1)

WinAC MP 377

• 1)

• 1)

• 1)

Panels – 170 series

Panels – 270 series
TP 277/OP 277
Multi Panels – 170 series
MP 177
Multi Panels – 270 series
MP 277
Multi Panels – 370 series
MP 377
WinAC MP

• Possible
1)

from WinCC (TIA Portal) V11 SP1

2)

from WinCC (TIA Portal) V11 SP2 Update 2
from WinCC (TIA Portal) V11 SP2

3)

2/4

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
Introduction
Introduction

■ Overview (continued)
WinCC flexible engineering software
Micro

Compact

Standard

Advanced

•5)

•5)

•5)

5)

5)

Basic Panels
KTP400 Basic mono PN
KTP600 Basic

•

•

•5)

KTP1000 Basic

•4)

•4)

•4)

TP1500 Basic

•4)

•4)

•4)

• 1)

• 1)

• 1)

2

Mobile Panels
Mobile Panel 177
Mobile Panel 277
Mobile Panel 277(F) IWLAN

•

2) 4)

• 2) 4)

•

3)

• 3)

Micro Panels
OP 73micro

•

•

•

•

TP 177micro

•

•

•

•

OP 73

•

•

•

OP 77A/B

•

•

•

TP 177A

•

•

•

TP/OP 177B

• 1)

• 1)

• 1)

• 2)

• 2)

• 4)

• 4)

•

•

• 3)

• 3)

• 5)

• 5)

•

5)

• 5)

•

5)

• 5)

Panels – 70 series

Panels – 170 series

Panels – 270 series
TP 277/OP 277
Multi Panels – 170 series
MP 177

• 5)

Multi Panels – 270 series
MP 277
Multi Panels – 370 series
MP 377
WinAC MP
WinAC MP 177

• 5)

WinAC MP 277
WinAC MP 377

• Possible
1)

WinCC flexible 2005 or higher and TP 177B 4" with WinCC flexible 2008 and higher

2)

WinCC flexible 2005 SP1 and higher
WinCC flexible 2007 and higher: Mobile Panel 277(F) IWLAN V1; WinCC flexible 2008 SP2 and higher: Mobile Panel 277(F) IWLAN V2

3)
4)
5)

WinCC flexible 2008 and higher
WinCC flexible 2008 SP1 and higher

Siemens ST 80 / ST PC · 2013

2/5

© Siemens AG 2013

Operator panels
Key Panels
SIMATIC HMI KP8/KP8F/32F

■ Overview

2
SIMATIC HMI KP32F and HMI KP8

Empty front (similar to figure)

Empty front (similar to figure)

2/6

Siemens ST 80 / ST PC · 2013

SIMATIC HMI Key Panels
• Optimum operability thanks to large mechanical keys and
multi-colored LED backlighting (daylight readable)
• Over 60% time savings for wiring and installation (Plug&Play)
• More than 30% savings in material costs compared to conventional keypad operator panels
• 2 PROFINET ports (incl. switch) already integrated for setting
up line and ring topologies
• Freely configurable digital I/Os on the rear for connecting
key-operated switches, indicator lamps, etc.
• Connection of fail-safe emergency stop buttons or other
fail-safe signals with KP8F and KP32F (in SIL2 or SIL3)
• Functionally compatible with all standard PROFINET master
CPUs, also non-Siemens
• KP8 and empty front design, also optimized for installation in
IPC Extension Units in IP65
• Maximum flexibility due to parameterization
• Empty front design for standardized assembly of flexible
operator panels
• KP8 and empty front design, also optimized for installation in
IPC Extension Units in IP65

© Siemens AG 2013

Operator panels
Key Panels
SIMATIC HMI KP8/KP8F/32F

■ Technical specifications
6AV3688-3AY36-0AX0

6AV3688-3AF37-0AX0

6AV3688-3EH47-0AX0

6AV3688-3XY38-3AX0

SIMATIC HMI KP8 PN

SIMATIC HMI KP8F PN

SIMATIC HMI KP32F PN

SIMATIC HMI
design empty front

Yes

Yes

Yes

No

Yes; Automatically when
switching on

Yes; Automatically when
switching on

Yes; Automatically when
switching on

No

Yes

Yes

Yes

No

8

8

32

0

8
5; Red, green, blue, white,
yellow
8

32
5; Red, green, blue, white,
yellow
32

0
0

• Number/keys

8
5; Red, green, blue, white,
yellow
8

Installation type/mounting
Rack mounting possible

Control elements
With parameterizable keys
With key and signal lamp test
Keyboard fonts
• freely inscribable membrane keys
• Short stroke keys
- Number of short-stroke keys
Expansions for operator control
of the process
• Number/LEDs
• Number of color modes for LED

2

0

No

No

No

No

Design/front/fastening

Yes; Compatible with
extension unit dimensions

Yes; Compatible with
extension unit dimensions

Yes

Yes; Compatible with
extension unit dimensions

Mounting rail installation possible

No

No

No

No

Wall mounting/direct mounting possible

No

No

No

No

Mounting in portrait format possible

Yes

Yes

Yes

Yes

Mounting in landscape format
possible

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

0

0

0

5; Max. 5 possible

Supply voltage
Type of supply voltage

DC

DC

DC

external

Rated voltage/DC

24 V

24 V

24 V

permissible range, lower limit (DC)

20.4 V

20.4 V

20.4 V

permissible range, upper limit (DC)

28.8 V

28.8 V

28.8 V

Type of output
LED colors
• Red
• Yellow
• Green
• white
• blue

Yes
Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes
Yes

No
No
No
No
No

8; Max. 8 inputs and
outputs (total)

8; Max. 32 inputs and
outputs (total)

32; Max. 32 inputs and
outputs (total)

0

8; Max. 8 inputs and outputs (total)

8; Max. 8 inputs and outputs (total)

16; Max. 32 inputs and
outputs (total)

0

Mounting technology
• Clamp terminals
Number of slots for command
devices and signaling units

Digital inputs
Number/binary inputs
Digital outputs
Number/binary outputs
Load "resistive"

100 mA

100 mA

100 mA

Voltage (DC)

24 V; Non-isolated

24 V; Non-isolated

24 V; Non-isolated

Number of digital outputs
• Output current (per output) max.
• Total current (per group), max.
• Short-circuit protection

100 mA
800 mA
Yes

100 mA
800 mA
Yes

100 mA
800 mA
Yes

No

Siemens ST 80 / ST PC · 2013

2/7

© Siemens AG 2013

Operator panels
Key Panels
SIMATIC HMI KP8/KP8F/32F

■ Technical specifications (continued)

2

6AV3688-3AY36-0AX0

6AV3688-3AF37-0AX0

6AV3688-3EH47-0AX0

6AV3688-3XY38-3AX0

SIMATIC HMI KP8 PN

SIMATIC HMI KP8F PN

SIMATIC HMI KP32F PN

SIMATIC HMI
design empty front

2; Incl. switch

2; Incl. switch

2; Incl. switch

0

2; For the construction of
lines and rings without
external switch
2; Per port
2; Per port

2; For the construction of
lines and rings without
external switch
2; Per port
2; Per port

2; For the construction of
lines and rings without
external switch
2; Per port
2; Per port

0

Protocols
PROFINET

Yes; Incl. shared device

Yes; Incl. shared device

Yes; Incl. shared device

No

Supports protocol for PROFINET IO

Yes

Yes

Yes

No

IRT supported

Yes

Yes

Yes

No

MRP supported

Yes

Yes

Yes

No

PROFINET CBA

No

No

No

No

Supports protocol for PROFIsafe

No

Yes; Mode V2.0; 2 inputs
can be used

Yes; Mode V2.0; 4 inputs
can be used

No

PROFIBUS

No

No

No

No

Test commissioning functions
Illuminant test

Yes; During switch on

Yes; During switch on

Yes; During switch on

No

Pushbutton and lamp test

Yes; During switch on

Yes; During switch on

Yes; During switch on

No

Yes; Group 1, measured
at a distance of 10 m
No

Yes; Group 1, measured
at a distance of 10 m
No

Yes; Group 1, measured
at a distance of 10 m
No

No

Degree and class of protection
Type of protection

IP20

IP20

IP20

IP20

IP (at the front)

IP65

IP65

IP65

IP65

Enclosure type 4x at the front

Yes; Incl. NEMA12

Yes; Incl. NEMA12

Yes; Incl. NEMA12

No

Standards, approvals, certificates
CE

Yes

Yes

Yes

Yes

KC approval

Yes

Yes

Yes

No

cULus

Yes

Yes

Yes

No

C-TICK

Yes

Yes

Yes

No

GL

No

No

No

No

ABS

No

No

No

No

BV

No

No

No

No

DNV

No

No

No

No

LRS

No

No

No

No

Class NK

No

No

No

No

PRS

No

No

No

No

Suitable for safety functions

No

Yes

Yes

Yes; e.g. installation of
emergency stop

Yes
Yes
No
Yes

Yes
Yes
No
Yes

No; On request
No; On request
No
Yes

No
No
No
No

Yes

Yes; Available soon

Yes

No

Interfaces
Supports protocol for PROFINET IO
• Number of PROFINET interfaces
Industrial Ethernet
• Number of industrial Ethernet
interfaces
• Industrial Ethernet status LED
• Number of ports of the integrated
switch

EMC
Emission of radio interference
acc. to EN 55 011
• Emission of radio interferences
acc. to EN 55 011 (limit class A)
• Emission of radio interference
acc. to EN 55 011 (limit class B)

Use in hazardous areas
• ATEX Zone 2
• ATEX Zone 22
• cULus Class I Zone 1
• cULus Class I Zone 2,
Division 2
• FM Class I Division 2

2/8

Siemens ST 80 / ST PC · 2013

0
0

No

© Siemens AG 2013

Operator panels
Key Panels
SIMATIC HMI KP8/KP8F/32F

■ Technical specifications (continued)
6AV3688-3AY36-0AX0

6AV3688-3AF37-0AX0

6AV3688-3EH47-0AX0

6AV3688-3XY38-3AX0

SIMATIC HMI KP8 PN

SIMATIC HMI KP8F PN

SIMATIC HMI KP32F PN

SIMATIC HMI
design empty front

vertical

vertical

vertical

Any

30°; To the front/rear

30°; To the front/rear

30°; To the front/rear

180°; To the front/rear

55 °C
0 °C

55 °C
0 °C

55 °C
0 °C

55 °C
0 °C

0 °C

0 °C

0 °C

0 °C

55 °C

55 °C

55 °C

55 °C

0 °C

0 °C

0 °C

0 °C

45 °C

45 °C

45 °C

45 °C

0 °C

0 °C

0 °C

0 °C

45 °C

45 °C

45 °C

45 °C

0 °C

0 °C

0 °C

0 °C

45 °C

45 °C

45 °C

45 °C

Storage/transport temperature
• Min.
• max.

-20 °C
60 °C

-20 °C
60 °C

-20 °C
60 °C

-20 °C
60 °C

Relative humidity
• max. relative humidity

95 %

95 %

95 %

95 %

Yes
Yes

Yes
Yes

Yes
Yes

No
No

Yes
Yes
No
Yes
No
Yes
No
No
No
No
No
No
No
No
No
No

Yes
Yes
No
Yes
No
Yes
No
No
No
No
No
No
No
No
No
No

Yes
Yes
No
Yes
No
Yes
No
No
No
No
No
No
No
No
No
No

Yes
Yes
No
Yes
No
Yes
No
No
No
No
No
No
No
No
No
No

Ambient conditions
Mounting position
maximum permissible angle of
inclination without external ventilation
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.
• Operation (vertical installation)
- in vertical mounting position/
minimum
- in vertical mounting position/
maximum
• Operation (max. tilt angle)
- at maximum tilt angle/
minimum
- at maximum tilt angle/
maximum
• Operation (vertical installation,
portrait format)
- in vertical mounting position/
minimum
- in vertical mounting position/
maximum
• Operation (max. tilt angle,
portrait format)
- at maximum tilt angle/
minimum
- at maximum tilt angle/
maximum

Configuration
Configuration software
• STEP 7 Basic (TIA Portal)
• STEP 7 Professional
(TIA Portal)
Functionality under
WinCC (TIA Portal)
Process coupling
• S7-1200
• S7-1500
• S7-200
• S7-300/400
• LOGO!
• Win AC
• SINUMERIK
• SIMOTION
• Allen Bradley (EtherNet/IP)
• Allen Bradley (DF1)
• Mitsubishi (MC TCP/IP)
• Mitsubishi (FX)
• OMRON (FINS TCP)
• OMRON (LINK/Multilink)
• Modicon (Modbus TCP/IP)
• Modicon (Modbus)

Siemens ST 80 / ST PC · 2013

2/9

2

© Siemens AG 2013

Operator panels
Key Panels
SIMATIC HMI KP8/KP8F/32F

■ Technical specifications (continued)

2

6AV3688-3AY36-0AX0

6AV3688-3AF37-0AX0

6AV3688-3EH47-0AX0

6AV3688-3XY38-3AX0

SIMATIC HMI KP8 PN

SIMATIC HMI KP8F PN

SIMATIC HMI KP32F PN

SIMATIC HMI
design empty front

Yes
No

Yes
No

No
Yes

No
Yes

1500000

1500000

1500000

Dimensions
Width of the housing front

98 mm

98 mm

295 mm

98 mm

Height of housing front

155 mm

155 mm

155 mm

155 mm

68 mm; Max. thickness of
mounting plate 2-6 mm
129 mm

68 mm; Max. thickness of
mounting plate 2-6 mm
129 mm

277 mm; Max. thickness of
mounting plate 2-6 mm
137 mm

68 mm; Max. thickness of
mounting plate 2-6 mm
129 mm

49 mm; Incl. angled
SIMATIC Ethernet
connector

49 mm; Incl. angled
SIMATIC Ethernet
connector

69 mm; Incl. angled
SIMATIC Ethernet
connector

49 mm

270 g

280 g

1 220 g

240 g

Mechanics/material
Type of housing (front)
• Plastic
• Aluminum
Lifetime, typ.
• Short-stroke keys
(in switching cycles)

Mounting cutout (W x H x D)
• Mounting cutout, width
• Mounting cutout, height
Depth/installation dimension

Weight
Weight without packaging

■ Ordering data
SIMATIC HMI KP8 PN

Order No.
6AV3688-3AY36-0AX0

Key Panel, 8 short-stroke keys with
multicolored LEDs, PROFINET interfaces, 2 x parameterizable with
STEP 7 V5.5 or higher
SIMATIC HMI KP8F PN

6AV3688-3AF37-0AX0

Key Panel, 8 short-stroke keys with
multicolored LEDs, PROFINET interfaces with PROFIsafe, parameterizable with STEP 7 V5.5 or higher;
4 additional fail-safe inputs. Can be
used as 2 x SIL 2 or 1 x SIL 3
SIMATIC HMI KP32F PN

6AV3688-3EH47-0AX0

Key Panel, 32 short-stroke keys with
multicolored LEDs, PROFINET interfaces with PROFIsafe, parameterizable with STEP 7 V5.5 or higher;
including 8 fail-safe inputs. Can be
used as 4 x SIL 2 or 2 x SIL 3
Empty front design

6AV3688-3XY38-3AX0

for standard 22.5 mm operator
controls, same mounting
dimensions as KP8
Demo case

A5E31477788

SIMATIC HMI Key Panel – low-cost
demo and experiment case
• Includes:
- 1x case
- 1x KP8 PN
- 1x CPU1211C
- 1x stand, permanently wired,
including program
• Power supply possible with a
standard laptop mains adapter
(not included in scope of supply)

Only by fax to
Siemens AG,
Mr. Michael Christ
Industry Sector,
I IA CE SE MF RS FDS
Wuerzburger Str. 121,
90766 Fuerth, Germany
Tel.: +49 911 750-4128
Fax: +49 911 750-2411

2/10

Siemens ST 80 / ST PC · 2013

Order No.
Documentation
You can find the manual for
the Key Panels on the Internet at:

http://support.automation.siemens.com/WW/view/en/56652789

Accessories

See SIMATIC HMI accessories,
from page 2/96

© Siemens AG 2013

Operator panels
Key Panels
SIMATIC HMI KP8/KP8F/32F

■ Dimensional drawings

■ More information

All dimensions in mm. For installation cutout, see technical
specifications.

Additional information is available on the Internet at:
http://www.siemens.com/simatic-key-panels

13.7

Note:
Do you need a specific modification or extension to the products
described here? If so, refer to "Customized Automation". There
you will find information about additional and generally available
sector-specific products as well as options for customer-specific
modification and adaptation.

127.7

155

Demo case
Can be ordered by fax:
Siemens AG, Mr. Michael Christ
Industry Sector, I IA CE SE MF RS FDS
Wuerzburger Str. 121, 90766 Fuerth, Germany
Phone: +49 911 750-4128
Fax: +49 911 750-2411
38

98

6

48.8
16.2
G_ST80_XX_00442

67.5

275

10

10

2 37

6
G_ST80_XX_00499

295

135

155

SIMATIC HMI Key Panel KP8; installation dimensions also valid for empty
front design

SIMATIC HMI Key Panel KP32F

Siemens ST 80 / ST PC · 2013

2/11

2

© Siemens AG 2013

Operator panels
Basic Panels
Basic Panels – Standard

■ Overview
• Ideal entry-level series from 3" to 15" for operating and
monitoring compact machines and systems
• Clear process representation thanks to use of pixel-graphics
displays
• Intuitive operation using Touch and tactile function keys
• Equipped with all the necessary basic functions such as alarm
logging, recipe management, plots, vector graphics, and
language switching
• Simple connection to the controller via integral Ethernet
interface or separate version with RS 485/422
• Faster commissioning thanks to integrated diagnostics viewer
and IP setting for SIMATIC S7-1200 and S7-1500 PLCs

2

■ Technical specifications
6AV6647-0AA11-3AX0

6AV6647-0AK11-3AX0

6AV6647-0AB11-3AX0

6AV6647-0AC11-3AX0

SIMATIC HMI KTP400
Basic mono PN

SIMATIC HMI KTP400
Basic color PN

SIMATIC HMI KTP600
Basic mono PN

SIMATIC HMI KTP600
Basic color DP

Display
Design of display

STN

TFT

STN

TFT

Screen diagonal

3.8 in

4.3 in

5.7 in

5.7 in

Number of colors

4; Grayscales

256

4; Grayscales

256

Resolution (pixels)
• Horizontal image resolution
• Vertical image resolution

320
240

480
272

320
240

320
240

Backlighting
• MTBF backlighting (at 25 °C)
• Dimmable backlight

30 000 h
No

50 000 h
No

50 000 h
No

50 000 h
No

Control elements
Keyboard fonts
• Number of function keys

4

4

6

6

Touch operation
• Design as touch screen

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Supply voltage
Type of supply voltage

DC

DC

DC

DC

Rated voltage/DC

24 V

24 V

24 V

24 V

Memory
Usable memory for user data

1 Mbyte

1 Mbyte

1 Mbyte

1 Mbyte

Type of output
Acoustics
• Buzzer

Yes

Yes

Yes

Yes

Time of day
Clock
• Software clock
• Battery-backed
• Synchronizable

Yes
No
Yes

Yes
No
Yes

Yes
No
Yes

Yes
No
Yes

Interfaces
Number of RS 485 interfaces

0

0

0

1

Number of USB interfaces

0

0

0

0

Number of SD card slots

0

0

0

0

Industrial Ethernet
• Number of industrial Ethernet
interfaces

1

1

1

0

Installation type/mounting
Mounting in portrait format
possible

2/12

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
Basic Panels
Basic Panels – Standard

■ Technical specifications (continued)
6AV6647-0AA11-3AX0

6AV6647-0AK11-3AX0

6AV6647-0AB11-3AX0

6AV6647-0AC11-3AX0

SIMATIC HMI KTP400
Basic mono PN

SIMATIC HMI KTP400
Basic color PN

SIMATIC HMI KTP600
Basic mono PN

SIMATIC HMI KTP600
Basic color DP

Protocols
PROFINET

Yes

Yes

Yes

No

PROFIBUS

No

No

No

Yes

MPI

No

No

No

Yes

Degree and class of
protection
Type of protection

IP20

IP20

IP20

IP20

IP (at the front)

IP65

IP65

IP65

IP65

Enclosure type 4x at the front

Yes

Yes

Yes

Yes

Standards, approvals,
certificates
CE

Yes

Yes

Yes

Yes

cULus

Yes

Yes

Yes

Yes

GL

Yes

Yes

Yes

Yes

ABS

Yes

Yes

Yes

Yes

BV

Yes

Yes

Yes

Yes

DNV

Yes

Yes

Yes

Yes

LRS

Yes

Yes

Yes

Yes

Class NK

Yes

Yes

Yes

Yes

No
No
No

No
No
No

No
No
No

No
No
No

No

No

No

No

0 °C

0 °C

0 °C

0 °C

50 °C

50 °C

50 °C

50 °C

90 %

90 %

90 %

90 %

Yes; via integrated WinCC
Basic (TIA Portal)
Yes
Yes

Yes; via integrated WinCC
Basic (TIA Portal)
No
Yes

Yes; via integrated WinCC
Basic (TIA Portal)
Yes
Yes

Yes; via integrated WinCC
Basic (TIA Portal)
Yes
Yes

5

5

5

5

No
Yes

No
Yes

No
Yes

No
Yes

200
15

200
15

200
15

200
15

256
Yes
Yes

256
Yes
Yes

256
Yes
Yes

256
Yes
Yes

5
40 kbyte
No

5
40 kbyte
No

5
40 kbyte
No

Use in hazardous areas
• ATEX Zone 2
• ATEX Zone 22
• cULus Class I Zone 2,
Division 2
• FM Class I Division 2
Ambient conditions
Operating temperature
• Operation (vertical
installation)
- in vertical mounting
position/ minimum
- in vertical mounting
position/ maximum
Relative humidity
• max. relative humidity
Configuration
Configuration software
• STEP 7 Basic (TIA Portal)
• WinCC flexible Compact
• WinCC Basic (TIA Portal)
Languages
Online languages
• Number of online/runtime
languages
Functionality under WinCC
(TIA Portal)
Task planner
• time-controlled
• task-controlled
With alarm logging system (incl.
buffer and acknowledgment)
• Number of bit messages
• Number of analog messages
• Message buffer
- Number of entries
- Circulating buffer
- retentive

Recipes
• Number of recipes
5
• Size of internal recipe memory 40 kbyte
No
• Recipe memory expandable

Siemens ST 80 / ST PC · 2013

2

2/13

© Siemens AG 2013

Operator panels
Basic Panels
Basic Panels – Standard

■ Technical specifications (continued)

2

6AV6647-0AA11-3AX0

6AV6647-0AK11-3AX0

6AV6647-0AB11-3AX0

6AV6647-0AC11-3AX0

SIMATIC HMI KTP400
Basic mono PN

SIMATIC HMI KTP400
Basic color PN

SIMATIC HMI KTP600
Basic mono PN

SIMATIC HMI KTP600
Basic color DP

250

500

500

500

30

30

30

30

Images
• Number of configurable
images

50

50

50

50

Archiving
• Number of archives per
device

0

0

0

0

Security
• Number of user groups
• Number of users

50
50

50
50

50
50

50
50

Transfer (upload/download)
• MPI/PROFIBUS DP
• Ethernet

No
Yes

No
Yes

No
Yes

Yes
No

Process coupling
• S7-1200
• S7-1500
• S7-200
• S7-300/400
• LOGO!
• Win AC
• SIMOTION
• Allen Bradley (EtherNet/IP)
• Allen Bradley (DF1)
• Mitsubishi (MC TCP/IP)
• Mitsubishi (FX)
• OMRON (FINS TCP)
• OMRON (LINK/Multilink)
• Modicon (Modbus TCP/IP)
• Modicon (Modbus)

Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
No
Yes
No
No
No
Yes
No

Yes
Yes
Yes
Yes
Yes
No
No
Yes
No
Yes
No
No
No
Yes
No

Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
No
Yes
No
No
No
Yes
No

Yes
Yes
Yes
Yes
Yes
Yes
No
No
Yes
No
Yes
No
Yes
No
Yes

I/O
I/O devices
• Printer
• Multi Media Card
• SD card
• USB memory

No
No
No
No

No
No
No
No

No
No
No
No

No
No
No
No

Mechanics/material
Type of housing (front)
• Plastic

Yes

Yes

Yes

Yes

Dimensions
Width of the housing front

140 mm

140 mm

214 mm

214 mm

Height of housing front

116 mm

116 mm

158 mm

158 mm

Mounting cutout (W x H x D)
• Mounting cutout, width
• Mounting cutout, height

123 mm
99 mm

123 mm
99 mm

197 mm
141 mm

197 mm
141 mm

Weight
Weight without packaging

0.32 kg

0.34 kg

1.07 kg

1.07 kg

Variables
• Number of variables per
device
• Number of variables per
screen

2/14

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
Basic Panels
Basic Panels – Standard

■ Technical specifications (continued)
6AV6647-0AD11-3AX0

6AV6647-0AE11-3AX0

6AV6647-0AF11-3AX0

SIMATIC HMI KTP600
Basic color PN

SIMATIC HMI KTP1000
Basic color DP

SIMATIC HMI KTP1000
Basic color PN

Display
Design of display

TFT

TFT

TFT

Screen diagonal

5.7 in

10.4 in

10.4 in

Number of colors

256

256

256

Resolution (pixels)
• Horizontal image resolution
• Vertical image resolution

320
240

640
480

640
480

Backlighting
• MTBF backlighting (at 25 °C)
• Dimmable backlight

50 000 h
No

50 000 h
No

50 000 h
No

Control elements
Keyboard fonts
• Number of function keys

6

8

8

Touch operation
• Design as touch screen

Yes

Yes

Yes

Installation type/mounting
Mounting in portrait format possible

Yes

No

No

Supply voltage
Type of supply voltage

DC

DC

DC

Rated voltage/DC

24 V

24 V

24 V

Memory
Usable memory for user data

1 Mbyte

2 Mbyte

2 Mbyte

Type of output
Acoustics
• Buzzer

Yes

Yes

Yes

Time of day
Clock
• Software clock
• Battery-backed
• Synchronizable

Yes
No
Yes

Yes
No
Yes

Yes
No
Yes

Interfaces
Number of RS 485 interfaces

0

1

0

Number of USB interfaces

0

0

0

Number of SD card slots

0

0

0

Industrial Ethernet
• Number of industrial Ethernet
interfaces

1

0

1

Protocols
PROFINET

Yes

No

Yes

PROFIBUS

No

Yes

No

MPI

No

Yes

No

Degree and class of protection
Type of protection

IP20

IP20

IP20

IP (at the front)

IP65

IP65

IP65

Enclosure type 4x at the front

Yes

Yes

Yes

Standards, approvals, certificates
CE

Yes

Yes

Yes

cULus

Yes

Yes

Yes

GL

Yes

Yes

Yes

ABS

Yes

Yes

Yes

BV

Yes

Yes

Yes

DNV

Yes

Yes

Yes

LRS

Yes

Yes

Yes

Class NK

Yes

Yes

Yes

Siemens ST 80 / ST PC · 2013

2

2/15

© Siemens AG 2013

Operator panels
Basic Panels
Basic Panels – Standard

■ Technical specifications (continued)

2

6AV6647-0AD11-3AX0

6AV6647-0AE11-3AX0

6AV6647-0AF11-3AX0

SIMATIC HMI KTP600
Basic color PN

SIMATIC HMI KTP1000
Basic color DP

SIMATIC HMI KTP1000
Basic color PN

No
No
No
No

No
No
No
No

No
No
No
No

0 °C

0 °C

0 °C

50 °C

50 °C

50 °C

90 %

90 %

90 %

• WinCC flexible Compact
• WinCC Basic (TIA Portal)

Yes; via integrated WinCC Basic
(TIA Portal)
Yes
Yes

Yes; via integrated WinCC Basic
(TIA Portal)
Yes
Yes

Yes; via integrated WinCC Basic
(TIA Portal)
Yes
Yes

Languages
Online languages
• Number of online/runtime languages

5

5

5

Functionality under WinCC
(TIA Portal)
Task planner
• time-controlled
• task-controlled

No
Yes

No
Yes

No
Yes

200
15

200
15

200
15

256
Yes
Yes

256
Yes
Yes

256
Yes
Yes

Recipes
• Number of recipes
• Size of internal recipe memory
• Recipe memory expandable

5
40 kbyte
No

5
40 kbyte
No

5
40 kbyte
No

Variables
• Number of variables per device
• Number of variables per screen

500
30

500
30

500
30

Images
• Number of configurable images

50

50

50

Archiving
• Number of archives per device

0

0

0

Security
• Number of user groups
• Number of users

50
50

50
50

50
50

Transfer (upload/download)
• MPI/PROFIBUS DP
• Ethernet

No
Yes

Yes
No

No
Yes

Use in hazardous areas
• ATEX Zone 2
• ATEX Zone 22
• cULus Class I Zone 2, Division 2
• FM Class I Division 2
Ambient conditions
Operating temperature
• Operation (vertical installation)
- in vertical mounting position/
minimum
- in vertical mounting position/
maximum
Relative humidity
• max. relative humidity
Configuration
Configuration software
• STEP 7 Basic (TIA Portal)

With alarm logging system
(incl. buffer and acknowledgment)
• Number of bit messages
• Number of analog messages
• Message buffer
- Number of entries
- Circulating buffer
- retentive

2/16

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
Basic Panels
Basic Panels – Standard

■ Technical specifications (continued)
6AV6647-0AD11-3AX0

6AV6647-0AE11-3AX0

6AV6647-0AF11-3AX0

SIMATIC HMI KTP600
Basic color PN

SIMATIC HMI KTP1000
Basic color DP

SIMATIC HMI KTP1000
Basic color PN

Process coupling
• S7-1200
• S7-1500
• S7-200
• S7-300/400
• LOGO!
• Win AC
• SIMOTION
• Allen Bradley (EtherNet/IP)
• Allen Bradley (DF1)
• Mitsubishi (MC TCP/IP)
• Mitsubishi (FX)
• OMRON (FINS TCP)
• OMRON (LINK/Multilink)
• Modicon (Modbus TCP/IP)
• Modicon (Modbus)

Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
No
Yes
No
No
No
Yes
No

Yes
Yes
Yes
Yes
Yes
Yes
No
No
Yes
No
Yes
No
Yes
No
Yes

Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
No
Yes
No
No
No
Yes
Yes

I/O
I/O devices
• Printer
• Multi Media Card
• SD card
• USB memory

No
No
No
No

No
No
No
No

No
No
No
No

Mechanics/material
Type of housing (front)
• Plastic

Yes

Yes

Yes

Dimensions
Width of the housing front

214 mm

335 mm

335 mm

Height of housing front

158 mm

275 mm

275 mm

Mounting cutout (W x H x D)
• Mounting cutout, width
• Mounting cutout, height

197 mm
141 mm

310 mm
248 mm

310 mm
248 mm

Weight
Weight without packaging

1.07 kg

2.65 kg

2.65 kg

Siemens ST 80 / ST PC · 2013

2

2/17

© Siemens AG 2013

Operator panels
Basic Panels
Basic Panels – Standard

■ Technical specifications (continued)

2

6AV6647-0AH11-3AX0

6AV6647-0AJ11-3AX0

6AV6647-0AG11-3AX0

SIMATIC HMI KP300
Basic mono PN

SIMATIC HMI KP400
Basic color PN

SIMATIC HMI TP1500
Basic color PN

Display
Design of display

FSTN

TFT

TFT

Screen diagonal

3.6 in

4.3 in

15 in

Number of colors

4; Backlit display only
(white, red, green, yellow)

256

256

Resolution (pixels)
• Horizontal image resolution
• Vertical image resolution

240
80

480
272

1 024
768

Backlighting
• MTBF backlighting (at 25 °C)
• Dimmable backlight

50 000 h
No

50 000 h
No

50 000 h
No

Control elements
Keyboard fonts
• Number of function keys

10

8

0

Touch operation
• Design as touch screen

No

No

Yes

Installation type/mounting
Mounting in portrait format possible

No

No

No

Supply voltage
Type of supply voltage

DC

DC

DC

Rated voltage/DC

24 V

24 V

24 V

Memory
Usable memory for user data

1 Mbyte

1 Mbyte

2 Mbyte

Type of output
Acoustics
• Buzzer

No

No

Yes

Time of day
Clock
• Software clock
• Battery-backed
• Synchronizable

Yes
No
Yes

Yes
No
Yes

Yes
No
Yes

Interfaces
Number of RS 485 interfaces

0

0

0

Number of USB interfaces

0

0

0

Number of SD card slots

0

0

0

Industrial Ethernet
• Number of industrial Ethernet
interfaces

1

1

1

Protocols
PROFINET

Yes

Yes

Yes

PROFIBUS

No

No

No

MPI

No

No

No

Degree and class of protection
Type of protection

IP20

IP20

IP20

IP (at the front)

IP65

IP65

IP65

Enclosure type 4x at the front

Yes

Yes

Yes

Standards, approvals, certificates
CE

Yes

Yes

Yes

cULus

Yes

Yes

Yes

GL

Yes

No

No

ABS

Yes

No

No

BV

Yes

No

No

DNV

Yes

No

No

LRS

Yes

No

No

Class NK

Yes

No

No

2/18

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
Basic Panels
Basic Panels – Standard

■ Technical specifications (continued)
6AV6647-0AH11-3AX0

6AV6647-0AJ11-3AX0

6AV6647-0AG11-3AX0

SIMATIC HMI KP300
Basic mono PN

SIMATIC HMI KP400
Basic color PN

SIMATIC HMI TP1500
Basic color PN

No
No
Yes
No

No
No
No
No

No
No
No
No

0 °C

0 °C

0 °C

50 °C

50 °C

50 °C

90 %

90 %

90 %

• WinCC flexible Compact
• WinCC Basic (TIA Portal)

Yes; via integrated WinCC Basic
(TIA Portal)
No
Yes

Yes; via integrated WinCC Basic
(TIA Portal)
No
Yes

Yes; via integrated WinCC Basic
(TIA Portal)
Yes
Yes

Languages
Online languages
• Number of online/runtime languages

5

5

5

Functionality under WinCC
(TIA Portal)
Task planner
• time-controlled
• task-controlled

No
Yes

No
Yes

No
Yes

200
15

200
15

200
15

256
Yes
Yes

256
Yes
Yes

256
Yes
Yes

Recipes
• Number of recipes
• Size of internal recipe memory
• Recipe memory expandable

5
40 kbyte
No

5
40 kbyte
No

5
40 kbyte
No

Variables
• Number of variables per device
• Number of variables per screen

250
30

500
30

500
30

Images
• Number of configurable images

50

50

50

Archiving
• Number of archives per device

0

0

0

Security
• Number of user groups
• Number of users

50
50

50
50

50
50

Transfer (upload/download)
• MPI/PROFIBUS DP
• Ethernet

No
Yes

No
Yes

No
Yes

Use in hazardous areas
• ATEX Zone 2
• ATEX Zone 22
• cULus Class I Zone 2, Division 2
• FM Class I Division 2
Ambient conditions
Operating temperature
• Operation (vertical installation)
- in vertical mounting position/
minimum
- in vertical mounting position/
maximum
Relative humidity
• max. relative humidity
Configuration
Configuration software
• STEP 7 Basic (TIA Portal)

With alarm logging system
(incl. buffer and acknowledgment)
• Number of bit messages
• Number of analog messages
• Message buffer
- Number of entries
- Circulating buffer
- retentive

Siemens ST 80 / ST PC · 2013

2

2/19

© Siemens AG 2013

Operator panels
Basic Panels
Basic Panels – Standard

■ Technical specifications (continued)

2

6AV6647-0AH11-3AX0

6AV6647-0AJ11-3AX0

6AV6647-0AG11-3AX0

SIMATIC HMI KP300
Basic mono PN

SIMATIC HMI KP400
Basic color PN

SIMATIC HMI TP1500
Basic color PN

Process coupling
• S7-1200
• S7-1500
• S7-200
• S7-300/400
• LOGO!
• Win AC
• SIMOTION
• Allen Bradley (EtherNet/IP)
• Allen Bradley (DF1)
• Mitsubishi (MC TCP/IP)
• Mitsubishi (FX)
• OMRON (FINS TCP)
• OMRON (LINK/Multilink)
• Modicon (Modbus TCP/IP)
• Modicon (Modbus)

Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
No
Yes
No
No
No
Yes
No

Yes
Yes
Yes
Yes
Yes
No
No
Yes
No
Yes
No
No
No
Yes
No

Yes
Yes
Yes
Yes
Yes
Yes
No
Yes
No
Yes
No
No
No
Yes
Yes

I/O
I/O devices
• Printer
• Multi Media Card
• SD card
• USB memory

No
No
No
No

No
No
No
No

No
No
No
No

Mechanics/material
Type of housing (front)
• Plastic

Yes

Yes

Yes

Dimensions
Width of the housing front

165 mm

162 mm

400 mm

Height of housing front

97 mm

189 mm

310 mm

Mounting cutout (W x H x D)
• Mounting cutout, width
• Mounting cutout, height

149 mm
82 mm

135 mm
171 mm

367 mm
289 mm

Weight
Weight without packaging

0.25 kg

0.51 kg

4.2 kg

2/20

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
Basic Panels
Basic Panels – Standard

■ Ordering data

Order No.

SIMATIC HMI Basic Panels,
Key and Touch

Order No.
Starter kits

6AV6647-0AA11-3AX0

Starter kit SIMATIC S7-1200 +
KP300 Basic mono PN

6AV6651-7HA01-3AA3

SIMATIC HMI KTP400
Basic mono PN

6AV6647-0AK11-3AX0

Starter kit SIMATIC S7-1200 +
KTP400 Basic color PN

6AV6651-7KA01-3AA3

SIMATIC HMI KTP400
Basic color PN

6AV6647-0AB11-3AX0

Starter kit SIMATIC S7-1200 +
KTP600 Basic color PN

6AV6651-7DA01-3AA3

SIMATIC HMI KTP600
Basic mono PN
SIMATIC HMI KTP600
Basic color DP

6AV6647-0AC11-3AX0

SIMATIC HMI KTP600
Basic color PN

6AV6647-0AD11-3AX0

SIMATIC HMI KTP1000
Basic color DP

6AV6647-0AE11-3AX0

SIMATIC HMI KTP1000
Basic color PN

6AV6647-0AF11-3AX0

SIMATIC HMI Basic Panels, Key
SIMATIC HMI KP300
Basic mono PN

6AV6647-0AH11-3AX0

SIMATIC HMI KP400
Basic color PN

6AV6647-0AJ11-3AX0

SIMATIC HMI Basic Panels, Touch
SIMATIC HMI TP1500
Basic color PN

6AV6647-0AG11-3AX0

2

Starter kits with an S7-1200
consist of:
• the respective SIMATIC HMI
Basic Panel
- SIMATIC HMI KP300
Basic mono PN
- SIMATIC HMI KTP400
Basic color PN
- SIMATIC HMI KTP600
Basic color PN
• SIMATIC S7-1200 CPU 1212C
AC/DC/Rly
• SIMATIC S7-1200
Simulator Module SIM 1274
• SIMATIC STEP 7 BASIC CD
• SIMATIC S7-1200 HMI
Manual Collection CD
• Ethernet CAT5 cable, 2 m
LOGO! starter kit + KP300
Basic mono PN

6AV2132-0HA00-0AA0

LOGO! starter kit + KTP400
Basic color PN

6AV2132-0KA00-0AA0

Starter kits with a LOGO! consist of:
• the respective SIMATIC HMI
Basic Panel
- SIMATIC HMI KP300
Basic mono PN
- SIMATIC HMI KTP400
Basic color PN
• LOGO! 12/24 RCE
• LOGO! POWER 24 V 1.3 A
• LOGO! SOFT COMFORT V7
• WINCC BASIC (TIA Portal)
• Ethernet CAT5 cable, 2 m
Documentation
You can find the manual for the
Basic Panels on the Internet at:

http://support.automation.siemens.com

Accessories

See HMI accessories,
from page 2/96

Siemens ST 80 / ST PC · 2013

2/21

© Siemens AG 2013

Operator panels
Basic Panels
Basic Panels – Standard

■ Dimensional drawings
All dimensions in mm. For installation cutout, see technical specifications.

148
165

98

116

2
28.9

KTP400 Basic color PN

190

122

170

KP300 Basic

122
G_ST80_XX_00517

6.2

33.5
39.7

G_ST80_XX_00462

81

96.6

141

116

98

SIMATIC PANEL

162

33.5

KTP400 Basic mono PN

2/22

Siemens ST 80 / ST PC · 2013

40

6.2

G_ST80_XX_00355

140

KP400 Basic

G_ST80_XX_00516

39.7
134

© Siemens AG 2013

Operator panels
Basic Panels
Basic Panels – Standard

■ Dimensional drawings (continued)

196
S

366

2

SIMATIC PANEL

SIMATIC PANEL

310

288

140

158

S

G_ST80_XX_00356

6.2

400

59.9

6.2

G_ST80_XX_00358

44

214

TP1500 Basic

KTP600 Basic

309
S

60.2

6.2

335

G_ST80_XX_00357

247

275

SIMATIC PANEL

KTP1000 Basic

■ More information
Additional information is available in the Internet under:
http://www.siemens.com/simatic-basic-panels
Note
Do you require a specific modification to or supplement for the
products described here? Look under "Customized products".
We provide information there about additional and generally
available sector products, and about the customer-specific
modification and adaptation options.

Siemens ST 80 / ST PC · 2013

2/23

© Siemens AG 2013

Operator panels
SIPLUS Basic Panels
SIPLUS Basic Panels

■ Overview
• Ideal entry-level series of 3.8 inches to 15 inches for operating
and monitoring compact machines and systems
• Clear process representation through the use of full-graphic
displays
• Intuitive operation via touch and tactile function keys
• Equipped with all the necessary basic functions such as
reporting, recipe management, curve representation, vector
graphics, and language selection
• Easy connection to the controller via integrated Ethernet
interface or a separate version with RS485/422

2

Note:
SIPLUS extreme products are based on Siemens Industry
standard products. The contents listed here were taken from the
respective standard products. SIPLUS extreme specific information was added.

SIPLUS HMI
KTP300 BASIC
MONO PN

SIPLUS HMI
KTP400 BASIC
MONO PN

SIPLUS HMI
KTP600 BASIC
COLOR PN

SIPLUS HMI
KTP1000 BASIC
COLOR DP

SIPLUS HMI
KTP1000 BASIC
COLOR PN

SIPLUS HMI
TP1500 BASIC
COLOR PN

Order number

6AG16470AH11-2AX0

6AG16470AA11-2AX0

6AG16470AD11-2AX0

6AG1647-0AE11- 6AG1647-0AF114AX0
4AX0

6AG16470AG11-4AX0

Order No. based on

6AV6647-0AH113AX0

6AV6647-0AA113AX0

6AV6647-0AD113AX0

6AV6647-0AE113AX0

6AV6647-0AF113AX0

6AV6647-0AG113AX0

Ambient temperature range

-25 ... +60 °C

-10 ... +60 °C

-25 ... +60 °C

0 ... +50 °C

0 ... +50 °C

0 ... +50 °C

Conformal coating

Coating of the printed circuit boards and the electronic components

Technical data

The technical data of the standard product applies except for the ambient conditions.

Ambient conditions
Relative humidity

100 %, condensation/frost permissible. No commissioning if condensation present.

Biologically active substances,
compliance with EN 60721-3-3

Class 3B2 mold and fungal spores (excluding fauna).
The supplied plug covers must remain in place over the unused interfaces during operation!

Chemically active substances,
compliance with EN 60721-3-3

Class 3C4 incl. salt spray in accordance with EN60068-2-52 (degree of severity 3).
The supplied plug covers must remain in place over the unused interfaces during operation!

Mechanically active substances,
compliance with EN 60721-3-3

Class 3S4 incl. sand, dust. The supplied plug covers must remain in place over the unused interfaces during operation!

Air pressure
(depending on the highest positive
temperature range specified)

1 080 ... 795 hPa (-1 000 ... +2 000 m)
see ambient temperature range
795 ... 658 hPa (+2000 ... +3500 m)
derating 10 K658 ... 540 hPa
(+3 500 ... +5 000 m)
derating 20 K

For technical documentation on SIPLUS, see:
http://www.siemens.com/siplus-extreme

2/24

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
SIPLUS Basic Panels
SIPLUS Basic Panels

■ Ordering data
SIPLUS HMI KTP300
Basic mono PN

Order No.
6AG1647-0AH11-2AX0

For areas with extreme medial
exposure (conformal coating);
ambient temperature -25 ... +60 °C
SIPLUS HMI KTP400
Basic mono PN

For areas with extreme medial
exposure (conformal coating);
ambient temperature -25 ... +60 °C

6AG1647-0AE11-4AX0

For areas with extreme medial
exposure (conformal coating);
ambient temperature 0 ... +50 °C
6AG1647-0AA11-2AX0

For areas with extreme medial
exposure (conformal coating);
ambient temperature -10 ... +60 °C
SIPLUS HMI KTP600
Basic color PN

Order No.
SIPLUS HMI KTP1000
Basic Color DP

SIPLUS HMI KTP1000
Basic Color PN

6AG1647-0AF11-4AX0

2

For areas with extreme medial
exposure (conformal coating);
ambient temperature 0 ... +50 °C
6AG1647-0AD11-2AX0

SIPLUS HMI TP1500
Basic Color PN

6AG1647-0AG11-4AX0

For areas with extreme medial
exposure (conformal coating);
ambient temperature 0 ... +50 °C
Accessories

See SIMATIC Basic Panels,
from page 2/12

Additional information is available in the Internet under:
http://www.siemens.com/simatic-basic-panels
Note
Do you require a specific modification to or supplement for the
products described here? Look under "Customized products".
We provide information there about additional and generally
available sector products, and about the customer-specific
modification and adaptation options.

Siemens ST 80 / ST PC · 2013

2/25

© Siemens AG 2013

Operator panels
Comfort Panels
Comfort Panels – Standard

■ Overview

2

• Excellent HMI functionality for demanding applications
• Widescreen TFT displays with 4", 7", 9", 12", 15", 19" and 22"
diagonals (all 16 million colors) with up to 40% more visualization area as compared to the predecessor devices
• Integrated high-end functionality with archives, scripts,
PDF/Word/Excel viewer, Internet Explorer, Media Player and
Web Server
• Dimmable displays from 0 to 100% via PROFIenergy, via the
HMI project or via a controller

• Modern industrial design, cast aluminum fronts for 7" upwards
• Upright installation for all touch devices
• Optimal selection option: seven touch and five key versions
are available
• Data security in the event of a power failure for the device and
for the SIMATIC HMI Memory Card
• Innovative service and commissioning concept through
second SD card (automatic backup)
• Easy project transfer via standard cable
(standard Ethernet cable, standard USB cable)
• Maximum performance with short screen refresh times
• Suitable for extremely harsh industrial environments thanks to
extended approvals such as ATEX 2/22 and marine approvals
• Wide range of communication options: PROFIBUS and
PROFINET onboard; 2 x PROFINET with integrated switch for
7" models or larger; plus 1 x PROFINET with Gigabit support
for 15" models or larger
• All variants can be used as an OPC UA client or as an OPC DA
server
• Key-operated devices with LED in every function key and new
text input mechanism, similar to the keypads of mobile phones
• All keys have a service life of 2 million operations
• Configuring with the WinCC engineering software of the
TIA Portal

■ Technical specifications
6AV2124-2DC01-0AX0

6AV2124-0GC01-0AX0

6AV2124-0JC01-0AX0

6AV2124-0MC01-0AX0

SIMATIC HMI KTP400
Comfort

SIMATIC HMI TP700
Comfort

SIMATIC HMI TP900
Comfort

SIMATIC HMI TP1200
Comfort

Display
Design of display

TFT

TFT

TFT

TFT

Screen diagonal

4.3 in

7 in

9 in

12.1 in

Number of colors

16 777 200

16 777 200

16 777 200

16 777 200

Resolution (pixels)
• Horizontal image resolution
• Vertical image resolution

480
272

800
480

800
480

1 280
800

Backlighting
• MTBF backlighting (at 25 °C)
• Dimmable backlight

80 000 h
Yes; 0-100 %

80 000 h
Yes; 0-100 %

80 000 h
Yes; 0-100 %

80 000 h
Yes; 0-100 %

Control elements
Keyboard fonts
• Number of function keys

4

0

0

0

Touch operation
• Design as touch screen

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Supply voltage
Type of supply voltage

DC

DC

DC

DC

Rated voltage/DC

24 V

24 V

24 V

24 V

Memory
Usable memory for user data

4 Mbyte

12 Mbyte

12 Mbyte

12 Mbyte

Type of output
Acoustics
• Speaker

No

Yes

Yes

Yes

Installation type/mounting
Mounting in portrait format
possible

2/26

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
Comfort Panels
Comfort Panels – Standard

■ Technical specifications (continued)
6AV2124-2DC01-0AX0

6AV2124-0GC01-0AX0

6AV2124-0JC01-0AX0

6AV2124-0MC01-0AX0

SIMATIC HMI KTP400
Comfort

SIMATIC HMI TP700
Comfort

SIMATIC HMI TP900
Comfort

SIMATIC HMI TP1200
Comfort

Yes

Yes

Yes

Yes

Yes
Yes

Yes
Yes

Yes
Yes

Yes
Yes

Interfaces
Number of RS 485 interfaces

1; RS 422/485 combined

1; RS 422/485 combined

1; RS 422/485 combined

1; RS 422/485 combined

Number of USB interfaces

1; USB 2.0

2; USB 2.0

2; USB 2.0

2; USB 2.0

Number of USB Mini B
interfaces

1; 5-pole

1; 5-pole

1; 5-pole

1; 5-pole

Number of SD card slots

2

2

2

2

1

2

2

2

1

2

2

2

Protocols
PROFINET

Yes

Yes

Yes

Yes

IRT supported

No

Yes

Yes

Yes

MRP supported

No

Yes

Yes

Yes

PROFIBUS

Yes

Yes

Yes

Yes

MPI

Yes

Yes

Yes

Yes

Degree and class of
protection
Type of protection

IP20

IP20

IP20

IP20

IP (at the front)

IP65

IP65

IP65

IP65

Enclosure type 4x at the front

Yes

Yes

Yes

Yes

Standards, approvals,
certificates
CE

Yes

Yes

Yes

Yes

cULus

Yes

Yes

Yes

Yes

GL

Yes

Yes

Yes

Yes

ABS

Yes

Yes

Yes

Yes

BV

Yes

Yes

Yes

Yes

DNV

Yes

Yes

Yes

Yes

LRS

Yes

Yes

Yes

Yes

Class NK

No; Available soon

No; Available soon

No; Available soon

No; Available soon

PRS

No

No

No

No

Yes
Yes
Yes

Yes
Yes
Yes

Yes
Yes
Yes

Yes
Yes
Yes

Yes

Yes

Yes

Yes

0 °C

0 °C

0 °C

0 °C

50 °C

50 °C

50 °C

50 °C

Relative humidity
• max. relative humidity

90 %

90 %

90 %

90 %

Configuration
Configuration software
• WinCC Comfort (TIA Portal)

Yes; from V11

Yes; from V11

Yes; from V11

Yes; from V11

Time of day
Clock
• Hardware clock
(real-time clock)
• Battery-backed
• Synchronizable

Industrial Ethernet
• Number of industrial Ethernet
interfaces
• Number of ports of the
integrated switch

Use in hazardous areas
• ATEX Zone 2
• ATEX Zone 22
• cULus Class I Zone 2,
Division 2
• FM Class I Division 2
Ambient conditions
Operating temperature
• Operation
(vertical installation)
- in vertical mounting
position/ minimum
- in vertical mounting
position/ maximum

Siemens ST 80 / ST PC · 2013

2

2/27

© Siemens AG 2013

Operator panels
Comfort Panels
Comfort Panels – Standard

■ Technical specifications (continued)

2

6AV2124-2DC01-0AX0

6AV2124-0GC01-0AX0

6AV2124-0JC01-0AX0

6AV2124-0MC01-0AX0

SIMATIC HMI KTP400
Comfort

SIMATIC HMI TP700
Comfort

SIMATIC HMI TP900
Comfort

SIMATIC HMI TP1200
Comfort

32

32

32

32

Functionality under WinCC
(TIA Portal)
Applications/options
• Internet Explorer
• Pocket Word
• Pocket Excel
• PDF Viewer
• Media Player
• SIMATIC WinCC Sm@rtServer

Yes
Yes
Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes
Yes
Yes

Visual Basic Scripts

Yes

Yes

Yes

Yes

Task planner
• time-controlled
• task-controlled

Yes
Yes

Yes
Yes

Yes
Yes

Yes
Yes

2 000
50

4 000
200

4 000
200

4 000
200

256
Yes
Yes

1 024
Yes
Yes

1 024
Yes
Yes

1 024
Yes
Yes

300
2 Mbyte
Yes

300
2 Mbyte
Yes

300
2 Mbyte
Yes

1 024

2 048

2 048

2 048

50

400

400

400

Images
• Number of configurable
images

500

500

500

500

Archiving
• Number of archives per
device

10

50

50

50

Security
• Number of user groups
• Number of users
• SIMATIC Logon

50
50
Yes

50
50
Yes

50
50
Yes

50
50
Yes

Logging through printer
• Alarms
• Report (shift log)
• Hardcopy
• Electronic print to file

Yes
Yes
Yes
Yes; pdf, html

Yes
Yes
Yes
Yes; pdf, html

Yes
Yes
Yes
Yes; pdf, html

Yes
Yes
Yes
Yes; pdf, html

Transfer (upload/download)
• MPI/PROFIBUS DP
• USB
• Ethernet

Yes
Yes
Yes

Yes
Yes
Yes

Yes
Yes
Yes

Yes
Yes
Yes

Languages
Online languages
• Number of online/runtime
languages

With alarm logging system (incl.
buffer and acknowledgment)
• Number of bit messages
• Number of analog messages
• Message buffer
- Number of entries
- Circulating buffer
- retentive

Recipes
• Number of recipes
100
• Size of internal recipe memory 512 kbyte
Yes
• Recipe memory expandable
Variables
• Number of variables per
device
• Number of variables per
screen

2/28

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
Comfort Panels
Comfort Panels – Standard

■ Technical specifications (continued)
6AV2124-2DC01-0AX0

6AV2124-0GC01-0AX0

6AV2124-0JC01-0AX0

6AV2124-0MC01-0AX0

SIMATIC HMI KTP400
Comfort

SIMATIC HMI TP700
Comfort

SIMATIC HMI TP900
Comfort

SIMATIC HMI TP1200
Comfort

Yes
Yes
Yes
Yes
Yes
Yes
No; With WinCC, subsequent
version
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
No

Yes
Yes
Yes
Yes
Yes
Yes
No; With WinCC, subsequent
version
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
No

Yes
Yes
Yes
Yes
Yes
Yes
No; With WinCC, subsequent
version
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
No

Yes
Yes
Yes
Yes
Yes
Yes
No; With WinCC, subsequent
version
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
No

I/O
I/O devices
• Printer
• Multi Media Card
• SD card
• USB memory
• Network camera

Yes
Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes
Yes

Mechanics/material
Type of housing (front)
• Plastic
• Aluminum

Yes
No

No
Yes

No
Yes

No
Yes

Dimensions
Width of the housing front

140 mm

214 mm

274 mm

330 mm

Height of housing front

116 mm

158 mm

190 mm

241 mm

Mounting cutout (W x H x D)
• Mounting cutout, width
• Mounting cutout, height

123 mm
99 mm

197 mm
141 mm

251 mm
166 mm

310 mm
221 mm

Weight
Weight without packaging

0.6 kg

1.4 kg

1.9 kg

2.8 kg

Process coupling
• S7-1200
• S7-1500
• S7-200
• S7-300/400
• LOGO!
• Win AC
• SIMOTION
•
•
•
•
•
•
•
•
•
•

Allen Bradley (EtherNet/IP)
Allen Bradley (DF1)
Mitsubishi (MC TCP/IP)
Mitsubishi (FX)
OMRON (FINS TCP)
OMRON (LINK/Multilink)
Modicon (Modbus TCP/IP)
Modicon (Modbus)
OPC UA Client
OPC UA Server

6AV2124-1DC01-0AX0

6AV2124-1GC01-0AX0

6AV2124-1JC01-0AX0

6AV2124-1MC01-0AX0

6AV2124-1QC02-0AX0

SIMATIC HMI
KP400 Comfort

SIMATIC HMI
KP700 Comfort

SIMATIC HMI
KP900 Comfort

SIMATIC HMI
KP1200 Comfort

SIMATIC HMI
KP1500 Comfort

Display
Design of display

TFT

TFT

TFT

TFT

TFT

Screen diagonal

4.3 in

7 in

9 in

12.1 in

15.4 in

Number of colors

16 777 200

16 777 200

16 777 200

16 777 200

16 777 200

Resolution (pixels)
• Horizontal image resolution
• Vertical image resolution

480
272

800
480

800
480

1 280
800

1 280
800

Backlighting
• MTBF backlighting (at 25 °C)
• Dimmable backlight

80 000 h
Yes; 0-100 %

80 000 h
Yes; 0-100 %

80 000 h
Yes; 0-100 %

80 000 h
Yes; 0-100 %

80 000 h
Yes; 0-100 %

Control elements
Keyboard fonts
• Number of function keys

8

24

26

34

36

Touch operation
• Design as touch screen

No

No

No

No

No

No

No

No

No

No

Supply voltage
Type of supply voltage

DC

DC

DC

DC

DC

Rated voltage/DC

24 V

24 V

24 V

24 V

24 V

Installation type/mounting
Mounting in portrait format
possible

Siemens ST 80 / ST PC · 2013

2/29

2

© Siemens AG 2013

Operator panels
Comfort Panels
Comfort Panels – Standard

■ Technical specifications (continued)

2

6AV2124-1DC01-0AX0

6AV2124-1GC01-0AX0

6AV2124-1JC01-0AX0

6AV2124-1MC01-0AX0

6AV2124-1QC02-0AX0

SIMATIC HMI
KP400 Comfort

SIMATIC HMI
KP700 Comfort

SIMATIC HMI
KP900 Comfort

SIMATIC HMI
KP1200 Comfort

SIMATIC HMI
KP1500 Comfort

Memory
Usable memory for user data

4 Mbyte

12 Mbyte

12 Mbyte

12 Mbyte

24 Mbyte

Type of output
Acoustics
• Speaker

No

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes
Yes

Yes
Yes

Yes
Yes

Yes
Yes

Yes
Yes

1; RS 422/485
combined

1; RS 422/485
combined

1; RS 422/485
combined

1; RS 422/485
combined

1; RS 422/485
combined

Number of USB interfaces

1; USB 2.0

2; USB 2.0

2; USB 2.0

2; USB 2.0

2; USB 2.0

Number of USB Mini B
interfaces

1; 5-pole

1; 5-pole

1; 5-pole

1; 5-pole

1; 5-pole

Number of SD card slots

2

2

2

2

2

1

2

2

2

3

1

2

2

2

2

Protocols
PROFINET

Yes

Yes

Yes

Yes

Yes

IRT supported

No

Yes

Yes

Yes

Yes

MRP supported

No

Yes

Yes

Yes

Yes

PROFIBUS

Yes

Yes

Yes

Yes

Yes

MPI

Yes

Yes

Yes

Yes

Yes

Degree and class of
protection
Type of protection

IP20

IP20

IP20

IP20

IP20

IP (at the front)

IP65

IP65

IP65

IP65

IP65

Enclosure type 4x at the front

Yes

Yes

Yes

Yes

Yes

Standards, approvals,
certificates
CE

Yes

Yes

Yes

Yes

Yes

cULus

Yes

Yes

Yes

Yes

Yes

GL

Yes

Yes

Yes

Yes

No

ABS

Yes

Yes

Yes

Yes

No

BV

Yes

Yes

Yes

Yes

No

DNV

Yes

Yes

Yes

Yes

No

LRS

Yes

Yes

Yes

Yes

No

Class NK

No; Available soon

No; Available soon

No; Available soon

No; Available soon

No

PRS

No

No

No

No

No

No; Available soon
No; Available soon
Yes

Yes
Yes
Yes

Yes
Yes
Yes

Yes
Yes
Yes

No
No
Yes

Yes

Yes

Yes

Yes

Yes

0 °C

0 °C

0 °C

0 °C

0 °C

50 °C

50 °C

50 °C

50 °C

50 °C

90 %

90 %

90 %

90 %

90 %

Time of day
Clock
• Hardware clock
(real-time clock)
• Battery-backed
• Synchronizable
Interfaces
Number of RS 485 interfaces

Industrial Ethernet
• Number of industrial Ethernet
interfaces
• Number of ports of the
integrated switch

Use in hazardous areas
• ATEX Zone 2
• ATEX Zone 22
• cULus Class I Zone 2,
Division 2
• FM Class I Division 2
Ambient conditions
Operating temperature
• Operation (vertical
installation)
- in vertical mounting
position/ minimum
- in vertical mounting
position/ maximum
Relative humidity
• max. relative humidity

2/30

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
Comfort Panels
Comfort Panels – Standard

■ Technical specifications (continued)
6AV2124-1DC01-0AX0

6AV2124-1GC01-0AX0

6AV2124-1JC01-0AX0

6AV2124-1MC01-0AX0

6AV2124-1QC02-0AX0

SIMATIC HMI
KP400 Comfort

SIMATIC HMI
KP700 Comfort

SIMATIC HMI
KP900 Comfort

SIMATIC HMI
KP1200 Comfort

SIMATIC HMI
KP1500 Comfort

Yes; from V11

Yes; from V11

Yes; from V11

Yes; from V11

Yes; V11 SP2 or higher

32

32

32

32

32

Functionality under WinCC
(TIA Portal)
Applications/options
• Internet Explorer
• Pocket Word
• Pocket Excel
• PDF Viewer
• Media Player
• SIMATIC WinCC Sm@rtServer

Yes
Yes
Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes
Yes
Yes

Visual Basic Scripts

Yes

Yes

Yes

Yes

Yes

Task planner
• time-controlled
• task-controlled

Yes
Yes

Yes
Yes

Yes
Yes

Yes
Yes

Yes
Yes

2 000
50

4 000
200

4 000
200

4 000
200

6 000
200

256
Yes
Yes

1 024
Yes
Yes

1 024
Yes
Yes

1 024
Yes
Yes

1 024
Yes
Yes

300
2 Mbyte
Yes

300
2 Mbyte
Yes

300
2 Mbyte
Yes

500
4 Mbyte
Yes

1 024

2 048

2 048

2 048

4 096

50

400

400

400

400

Images
• Number of configurable
images

500

500

500

500

750

Archiving
• Number of archives per
device

10

50

50

50

50

Security
• Number of user groups
• Number of users
• SIMATIC Logon

50
50
Yes

50
50
Yes

50
50
Yes

50
50
Yes

50
50
Yes

Logging through printer
• Alarms
• Report (shift log)
• Hardcopy
• Electronic print to file

Yes
Yes
Yes
Yes; pdf, html

Yes
Yes
Yes
Yes; pdf, html

Yes
Yes
Yes
Yes; pdf, html

Yes
Yes
Yes
Yes; pdf, html

Yes
Yes
Yes
Yes; pdf, html

Transfer (upload/download)
• MPI/PROFIBUS DP
• USB
• Ethernet

Yes
Yes
Yes

Yes
Yes
Yes

Yes
Yes
Yes

Yes
Yes
Yes

Yes
Yes
Yes

Configuration
Configuration software
• WinCC Comfort (TIA Portal)
Languages
Online languages
• Number of online/runtime
languages

With alarm logging system (incl.
buffer and acknowledgment)
• Number of bit messages
• Number of analog messages
• Message buffer
- Number of entries
- Circulating buffer
- retentive

Recipes
• Number of recipes
100
• Size of internal recipe memory 512 kbyte
• Recipe memory expandable
Yes
Variables
• Number of variables per
device
• Number of variables per
screen

Siemens ST 80 / ST PC · 2013

2/31

2

© Siemens AG 2013

Operator panels
Comfort Panels
Comfort Panels – Standard

■ Technical specifications (continued)

2

6AV2124-1DC01-0AX0

6AV2124-1GC01-0AX0

6AV2124-1JC01-0AX0

6AV2124-1MC01-0AX0

6AV2124-1QC02-0AX0

SIMATIC HMI
KP400 Comfort

SIMATIC HMI
KP700 Comfort

SIMATIC HMI
KP900 Comfort

SIMATIC HMI
KP1200 Comfort

SIMATIC HMI
KP1500 Comfort

Yes
Yes
Yes
Yes
Yes
Yes
No; With WinCC,
subsequent version
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
No

Yes
Yes
Yes
Yes
Yes
Yes
No; With WinCC,
subsequent version
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
No

Yes
Yes
Yes
Yes
Yes
Yes
No; With WinCC,
subsequent version
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
No

Yes
Yes
Yes
Yes
Yes
Yes
No; With WinCC,
subsequent version
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
No

Yes
Yes
Yes
Yes
Yes
Yes
No; With WinCC,
subsequent version
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
No

I/O
I/O devices
• Printer
• Multi Media Card
• SD card
• USB memory
• Network camera

Yes
Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes
Yes

Mechanics/material
Type of housing (front)
• Plastic
• Aluminum

Yes
No

No
Yes

No
Yes

No
Yes

No
Yes

Dimensions
Width of the housing front

152 mm

308 mm

362 mm

454 mm

483 mm

Height of housing front

188 mm

204 mm

230 mm

289 mm

310 mm

Mounting cutout (W x H x D)
• Mounting cutout, width
• Mounting cutout, height

135 mm
171 mm

281 mm
177 mm

338 mm
206 mm

434 mm
269 mm

450 mm
291 mm

Weight
Weight without packaging

0.8 kg

2.2 kg

2.7 kg

4.4 kg

5.4 kg

Process coupling
• S7-1200
• S7-1500
• S7-200
• S7-300/400
• LOGO!
• Win AC
• SIMOTION
•
•
•
•
•
•
•
•
•
•

Allen Bradley (EtherNet/IP)
Allen Bradley (DF1)
Mitsubishi (MC TCP/IP)
Mitsubishi (FX)
OMRON (FINS TCP)
OMRON (LINK/Multilink)
Modicon (Modbus TCP/IP)
Modicon (Modbus)
OPC UA Client
OPC UA Server

2/32

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
Comfort Panels
Comfort Panels – Standard

■ Technical specifications (continued)
6AV2124-0QC02-0AX0

6AV2124-0UC02-0AX0

6AV2124-0XC02-0AX0

SIMATIC HMI TP1500 Comfort

SIMATIC HMI TP1900 Comfort

SIMATIC HMI TP2200 Comfort

Display
Design of display

TFT

TFT

TFT

Screen diagonal

15.4 in

18.5 in

21.5 in

Number of colors

16 777 200

16 777 200

16 777 200

Resolution (pixels)
• Horizontal image resolution
• Vertical image resolution

1 280
800

1 366
768

1 920
1 080

Backlighting
• MTBF backlighting (at 25 °C)
• Dimmable backlight

80 000 h
Yes; 0-100 %

50 000 h
Yes; 0-100 %

30 000 h
Yes; 0-100 %

Control elements
Keyboard fonts
• Number of function keys

0

0

0

Touch operation
• Design as touch screen

Yes

Yes

Yes

Yes

Yes

Yes

Supply voltage
Type of supply voltage

DC

DC

DC

Rated voltage/DC

24 V

24 V

24 V

Memory
Usable memory for user data

24 Mbyte

24 Mbyte

24 Mbyte

Type of output
Acoustics
• Speaker

Yes

Yes

Yes

Yes

Yes

Yes

Yes
Yes

Yes
Yes

Yes
Yes

Interfaces
Number of RS 485 interfaces

1; RS 422/485 combined

1; RS 422/485 combined

1; RS 422/485 combined

Number of USB interfaces

2; USB 2.0

2; USB 2.0

2; USB 2.0

Number of USB Mini B
interfaces

1; 5-pole

1; 5-pole

1; 5-pole

Number of SD card slots

2

2

2

3

3

3

2

2

2

Protocols
PROFINET

Yes

Yes

Yes

IRT supported

Yes

Yes

Yes

MRP supported

Yes

Yes

Yes

PROFIBUS

Yes

Yes

Yes

MPI

Yes

Yes

Yes

Degree and class of
protection
Type of protection

IP20

IP20

IP20

IP (at the front)

IP65

IP65

IP65

Enclosure type 4x at the front

Yes

Yes

Yes

Installation type/mounting
Mounting in portrait format
possible

Time of day
Clock
• Hardware clock
(real-time clock)
• Battery-backed
• Synchronizable

Industrial Ethernet
• Number of industrial Ethernet
interfaces
• Number of ports of the
integrated switch

Siemens ST 80 / ST PC · 2013

2

2/33

© Siemens AG 2013

Operator panels
Comfort Panels
Comfort Panels – Standard

■ Technical specifications (continued)

2

6AV2124-0QC02-0AX0

6AV2124-0UC02-0AX0

6AV2124-0XC02-0AX0

SIMATIC HMI TP1500 Comfort

SIMATIC HMI TP1900 Comfort

SIMATIC HMI TP2200 Comfort

Standards, approvals,
certificates
CE

Yes

Yes

Yes

cULus

Yes

Yes

Yes

GL

No

No

No

ABS

No

No

No

BV

No

No

No

DNV

No

No

No

LRS

No

No

No

Class NK

No

No

No

PRS

No

No

No

No
No
Yes

No
No
Yes

No
No
Yes

Yes

Yes

Yes

0 °C

0 °C

0 °C

50 °C

45 °C

45 °C

Relative humidity
• max. relative humidity

90 %

90 %

90 %

Configuration
Configuration software
• WinCC Comfort (TIA Portal)

Yes; V11 SP2 or higher

Yes; V11 SP2 or higher

Yes; V11 SP2 or higher

32

32

32

Functionality under WinCC
(TIA Portal)
Applications/options
• Internet Explorer
• Pocket Word
• Pocket Excel
• PDF Viewer
• Media Player
• SIMATIC WinCC Sm@rtServer

Yes
Yes
Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes
Yes
Yes

Visual Basic Scripts

Yes

Yes

Yes

Task planner
• time-controlled
• task-controlled

Yes
Yes

Yes
Yes

Yes
Yes

6 000
200

6 000
200

6 000
200

1 024
Yes
Yes

1 024
Yes
Yes

1 024
Yes
Yes

500
4 Mbyte
Yes

500
4 Mbyte
Yes

4 096

4 096

4 096

400

400

400

Use in hazardous areas
• ATEX Zone 2
• ATEX Zone 22
• cULus Class I Zone 2,
Division 2
• FM Class I Division 2
Ambient conditions
Operating temperature
• Operation (vertical
installation)
- in vertical mounting
position/ minimum
- in vertical mounting
position/ maximum

Languages
Online languages
• Number of online/runtime
languages

With alarm logging system (incl.
buffer and acknowledgment)
• Number of bit messages
• Number of analog messages
• Message buffer
- Number of entries
- Circulating buffer
- retentive

Recipes
• Number of recipes
500
• Size of internal recipe memory 4 Mbyte
• Recipe memory expandable
Yes
Variables
• Number of variables per
device
• Number of variables per
screen

2/34

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
Comfort Panels
Comfort Panels – Standard

■ Technical specifications (continued)
6AV2124-0QC02-0AX0

6AV2124-0UC02-0AX0

6AV2124-0XC02-0AX0

SIMATIC HMI TP1500 Comfort

SIMATIC HMI TP1900 Comfort

SIMATIC HMI TP2200 Comfort

Images
• Number of configurable
images

750

750

750

Archiving
• Number of archives per
device

50

50

50

Security
• Number of user groups
• Number of users
• SIMATIC Logon

50
50
Yes

50
50
Yes

50
50
Yes

Logging through printer
• Alarms
• Report (shift log)
• Hardcopy
• Electronic print to file

Yes
Yes
Yes
Yes; pdf, html

Yes
Yes
Yes
Yes; pdf, html

Yes
Yes
Yes
Yes; pdf, html

Transfer (upload/download)
• MPI/PROFIBUS DP
• USB
• Ethernet

Yes
Yes
Yes

Yes
Yes
Yes

Yes
Yes
Yes

Process coupling
• S7-1200
• S7-1500
• S7-200
• S7-300/400
• LOGO!
• Win AC
• SIMOTION
• Allen Bradley (EtherNet/IP)
• Allen Bradley (DF1)
• Mitsubishi (MC TCP/IP)
• Mitsubishi (FX)
• OMRON (FINS TCP)
• OMRON (LINK/Multilink)
• Modicon (Modbus TCP/IP)
• Modicon (Modbus)
• OPC UA Client
• OPC UA Server

Yes
Yes
Yes
Yes
Yes
Yes
No; With WinCC, subsequent version
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
No

Yes
Yes
Yes
Yes
Yes
Yes
No; With WinCC, subsequent version
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
No

Yes
Yes
Yes
Yes
Yes
Yes
No; With WinCC, subsequent version
Yes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
No

I/O
I/O devices
• Printer
• Multi Media Card
• SD card
• USB memory
• Network camera

Yes
Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes
Yes

Mechanics/material
Type of housing (front)
• Plastic
• Aluminum

No
Yes

No
Yes

No
Yes

Dimensions
Width of the housing front

415 mm

483 mm

560 mm

Height of housing front

310 mm

337 mm

380 mm

Mounting cutout (W x H x D)
• Mounting cutout, width
• Mounting cutout, height

396 mm
291 mm

465 mm
319 mm

542 mm
362 mm

Weight
Weight without packaging

5.2 kg

6.5 kg

7.1 kg

Siemens ST 80 / ST PC · 2013

2

2/35

© Siemens AG 2013

Operator panels
Comfort Panels
Comfort Panels – Standard

■ Ordering data

Order No.

SIMATIC HMI Comfort Panels,
Key and Touch
SIMATIC HMI KTP400 Comfort

6AV2124-2DC01-0AX0

SIMATIC HMI Comfort Panels,
Touch

2

SIMATIC HMI TP700 Comfort

6AV2124-0GC01-0AX0

SIMATIC HMI TP900 Comfort

6AV2124-0JC01-0AX0

SIMATIC HMI TP1200 Comfort

6AV2124-0MC01-0AX0

SIMATIC HMI TP1500 Comfort

6AV2124-0QC02-0AX0

SIMATIC HMI TP1900 Comfort

6AV2124-0UC02-0AX0

SIMATIC HMI TP2200 Comfort

6AV2124-0XC02-0AX0

SIMATIC HMI Comfort Panels, Key
SIMATIC HMI KP400 Comfort

6AV2124-1DC01-0AX0

SIMATIC HMI KP700 Comfort

6AV2124-1GC01-0AX0

SIMATIC HMI KP900 Comfort

6AV2124-1JC01-0AX0

SIMATIC HMI KP1200 Comfort

6AV2124-1MC01-0AX0

SIMATIC HMI KP1500 Comfort

6AV2124-1QC02-0AX0

2/36

Siemens ST 80 / ST PC · 2013

Order No.
Starter kits for SIMATIC HMI
Comfort Panels
Consisting of:
the respective SIMATIC HMI
Comfort Panel, SIMATIC WinCC
Comfort, Ethernet cable, 2 m
SIMATIC HMI memory card 2 GB
10 protective films for touch screen
devices
Starter kit for SIMATIC HMI
KTP400 Comfort,
Key and Touch

6AV2181-4DB20-0AX0

Starter kit for SIMATIC HMI
TP700 Comfort, Touch

6AV2181-4GB00-0AX0

Starter kit for SIMATIC HMI
TP900 Comfort, Touch

6AV2181-4JB00-0AX0

Starter kit for SIMATIC HMI
TP1200 Comfort, Touch

6AV2181-4MB00-0AX0

Starter kit for SIMATIC HMI
TP1500 Comfort, Touch

6AV2181-4QB00-0AX0

Starter kit for SIMATIC HMI
TP1900 Comfort, Touch

6AV2181-4UB00-0AX0

Starter kit for SIMATIC HMI
TP2200 Comfort, Touch

6AV2181-4XB00-0AX0

Starter kit for SIMATIC HMI
KP400 Comfort, Key

6AV2181-4DB10-0AX0

Starter kit for SIMATIC HMI
KP700 Comfort, Key

6AV2181-4GB10-0AX0

Starter kit for SIMATIC HMI
KP900 Comfort, Key

6AV2181-4JB10-0AX0

Starter kit for SIMATIC HMI
KP1200 Comfort, Key

6AV2181-4MB10-0AX0

Starter kit for SIMATIC HMI
KP1500 Comfort, Key

6AV2181-4QB10-0AX0

Accessories

See HMI accessories,
from page 2/96

© Siemens AG 2013

Operator panels
Comfort Panels
Comfort Panels – Standard

■ Dimensional drawings

2

219

241

140

158

138.8

All dimensions in mm. For installation cutout, see technical specifications.

32.5

214

32.5

330

62.8

64.3

69
196

70.5

G_ST80_XX_00449

308

274

G_ST80_XX_00451

182

289

310

164
138.8

TP1200 Comfort

190

TP700 Comfort

194.7

32.5
47.6

415
63.1

TP900 Comfort

79.3

G_ST80_XX_00511

194.7

73.1

69.3
G_ST80_XX_00450

249

281
394

TP1500 Comfort

Siemens ST 80 / ST PC · 2013

2/37

© Siemens AG 2013

Operator panels
Comfort Panels
Comfort Panels – Standard

483

170

188

182

337

2

317

98

■ Dimensional drawings (continued)

47.6
18

73.1

152

48

79.3
134

463

308
47.6

69
280

79.3

TP2200 Comfort

2/38

Siemens ST 80 / ST PC · 2013

G_ST80_XX_00513

194.7
281

138.8
62.8

73.1

540

32.5

KP700 Comfort

G_ST80_XX_00445

560

176

204

182

360

KP400 Comfort

380

TP1900 Comfort

G_ST80_XX_00444

G_ST80_XX_00512

281

55.8

© Siemens AG 2013

Operator panels
Comfort Panels
Comfort Panels – Standard

182

289

310

47.6

483

32.5
62.8

73.1

69

79.3
G_ST80_XX_00446

336

2

194.7

281
448

KP1500 Comfort

140
454

98

116

267

289

138.8

KP900 Comfort

G_ST80_XX_00510

362

204
138.8

230

■ Dimensional drawings (continued)

18

32.5

48.6
64.5

54.8

70.5

122

KP1200 Comfort

G_ST80_XX_00448

G_ST80_XX_00447

432
194.7

KTP400 Comfort

■ More information
Additional information is available on the Internet at:
http://www.siemens.com/simatic-comfort-panels
You can find an overview of approved printers, supply sources
and printer settings on the Internet at:
http://support.automation.siemens.com/WW/view/en/11376409

Note
Do you need a specific modification or extension to the products
described here? If so, refer to "Customized Automation". There
you will find information about additional and generally available
sector-specific products as well as options for customer-specific
modification and adaptation.

Siemens ST 80 / ST PC · 2013

2/39

© Siemens AG 2013

Operator panels
SIPLUS Comfort Panels
SIPLUS Comfort Panels

■ Overview

2

• Excellent HMI functionality for demanding applications
• Widescreen TFT displays with 4", 7", 9", 12", 15", 19" and 22"
diagonals (all 16 million colors) with up to 40% more visualization area as compared to the predecessor devices
• Integrated high-end functionality with archives, scripts,
PDF/Word/Excel viewer, Internet Explorer, Media Player
• Dimmable displays from 0 to 100% via PROFIenergy, via the
HMI project or via a controller
• Modern industrial design, cast aluminum fronts for 7" upwards
• Upright installation for all touch devices
• Optimal selection option: seven touch and five key versions
are available

2/40

Siemens ST 80 / ST PC · 2013

• Data security in the event of a power failure for the device and
for the SIMATIC HMI Memory Card
• Innovative service and commissioning concept through
second SD card (automatic backup)
• Easy project transfer via standard cable
(standard Ethernet cable, standard USB cable)
• Maximum performance with short screen refresh times
• Suitable for extremely harsh industrial environments thanks to
extended approvals such as ATEX 2/22
• Wide range of communication options: PROFIBUS and
PROFINET onboard; 2x PROFINET with integrated switch for
7" models or larger; plus 1 additional PROFINET with Gigabit
support for 15" models or larger
• All variants can be used as an OPC UA client or as an OPC DA
server
• Key-operated devices with LED in every function key and new
text input mechanism, similar to the keypads of mobile phones
• Key-operated devices with stamped keys for optimum tactile
feedback
• All keys have a service life of 2 million operations
• Configuring with the WinCC engineering software of the
TIA Portal
Note:
SIPLUS extreme products are based on Siemens Industry
standard products. The contents listed here were taken from the
respective standard products. SIPLUS extreme-specific information was added.

© Siemens AG 2013

Operator panels
SIPLUS Comfort Panels
SIPLUS Comfort Panels

■ Technical specifications

Ambient conditions
Operating temperature
• Operation
(vertical installation)
- in vertical mounting
position/ minimum
- in vertical mounting
position/ maximum
Extended ambient conditions
• Relative humidity
- With condensation/
maximum/tested in accordance with IEC 60068-2-38
• Resistance
- to biologically active
substances
- to chemically active
substances
- to mechanically active
substances

Ambient conditions
Operating temperature
• Operation
(vertical installation)
- in vertical mounting
position/ minimum
- in vertical mounting
position/ maximum
Extended ambient conditions
• Relative humidity
- With condensation/
maximum/tested in accordance with IEC 60068-2-38
• Resistance
- to biologically active
substances
- to chemically active
substances
- to mechanically active
substances

6AG1124-2DC01-4AX0

6AG1124-0GC01-4AX0

6AG1124-0JC01-4AX0

6AG1124-0MC01-4AX0

SIPLUS HMI KTP400
Comfort

SIPLUS HMI TP700
Comfort

SIPLUS HMI TP900
Comfort

SIPLUS HMI TP1200
Comfort

0 °C

0 °C

0 °C

0 °C

50 °C

50 °C

50 °C

50 °C

100 %

100 %

100 %

100 %

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

2

6AG1124-1DC01-4AX0

6AG1124-1GC01-4AX0

6AG1124-1JC01-4AX0

6AG1124-1MC01-4AX0

6AG1124-1QC02-4AX0

SIPLUS HMI KTP400
Comfort

SIPLUS HMI KP700
Comfort

SIPLUS HMI KP900
Comfort

SIPLUS HMI KP1200
Comfort

SIPLUS HMI KP1500
Comfort

0 °C

0 °C

0 °C

0 °C

0 °C

50 °C

50 °C

50 °C

50 °C

50 °C

100 %

100 %

100 %

100 %

100 %

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Siemens ST 80 / ST PC · 2013

2/41

© Siemens AG 2013

Operator panels
SIPLUS Comfort Panels
SIPLUS Comfort Panels

■ Technical specifications (continued)

2

Ambient conditions
Operating temperature
• Operation
(vertical installation)
- in vertical mounting
position/ minimum
- in vertical mounting
position/ maximum
Extended ambient conditions
• Relative humidity
- With condensation/
maximum/tested in accordance with IEC 60068-2-38
• Resistance
- to biologically active
substances
- to chemically active
substances
- to mechanically active
substances

2/42

6AG1124-0QC02-4AX0

6AG1124-0UC02-4AX0

6AG1124-0XC02-4AX0

SIPLUS HMI TP1500 Comfort

SIPLUS HMI TP1900 Comfort

SIPLUS HMI TP2200 Comfort

0 °C

0 °C

0 °C

50 °C

45 °C

45 °C

100 %

100 %

100 %

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
SIPLUS Comfort Panels
SIPLUS Comfort Panels

■ Ordering data

Order No.

SIPLUS HMI KTP400 Comfort

■ More information
Additional information is available on the Internet at:
http://www.siemens.com/simatic-comfort-panels

SIPLUS HMI Comfort Panels,
Keys and Touch
6AG1124-2DC01-4AX0

SIPLUS HMI Comfort Panels,
Touch
SIPLUS HMI TP700 Comfort

6AG1124-0GC01-4AX0

SIPLUS HMI TP900 Comfort

6AG1124-0JC01-4AX0

SIPLUS HMI TP1200 Comfort

6AG1124-1MC01-4AX0

SIPLUS HMI TP1500 Comfort

6AG1124-0QC02-4AX0

SIPLUS HMI TP1900 Comfort

6AG1124-0UC02-4AX0

SIPLUS HMI TP2200 Comfort

6AG1124-0XC02-4AX0

You can find an overview of approved printers, supply sources
and printer settings on the Internet at:
http://support.automation.siemens.com/WW/view/en/11376409
Note
Do you need a specific modification or extension to the products
described here? If so, refer to "Customized Automation". There
you will find information about additional and generally available
sector-specific products as well as options for customer-specific
modification and adaptation.

SIPLUS HMI Comfort Panels,
Keys
SIPLUS HMI KP400 Comfort

6AG1124-1DC01-4AX0

SIPLUS HMI KP700 Comfort

6AG1124-1GC01-4AX0

SIPLUS HMI KP900 Comfort

6AG1124-1JC01-4AX0

SIPLUS HMI KP1200 Comfort

6AG1124-1MC01-4AX0

SIPLUS HMI KP1500 Comfort

6AG1124-1QC02-4AX0

Accessories

See HMI accessories,
from page 2/26

Siemens ST 80 / ST PC · 2013

2/43

2

© Siemens AG 2013

Operator panels
Mobile Panels
Mobile Panels

■ Overview

2

SIMATIC Mobile Panel
• Mobile operator panel for direct operator control of the plant
and machine from any point
• Supports an optimum view of the workpiece or process and,
at the same time, direct access and visual contact with the
operator panel
• Versatile use thanks to easy unplugging and replugging
during normal operation (Mobile Panel 177 and
Mobile Panel 277) or
• Wireless freedom (Mobile Panel 277(F) IWLAN)
• Pixel-graphics, high-luminance color display with touch
screen (analog/resistive)
• PROFIBUS or PROFINET communication, PROFINET over
WLAN for Mobile Panel 277(F) IWLAN
• Freely-configurable function keys with customized labels
(with LED) (not for Mobile Panel 277 10")
SIMATIC Mobile Panel 177 and SIMATIC Mobile Panel 277
• Two three-stage acknowledgement buttons;
Optional versions include:
- STOP button
- STOP button, handwheel, key-operated switch and
illuminated pushbutton (not for Mobile Panel 277 10")
• Communication is supported via a serial link, MPI/PROFIBUS
or PROFINET
• Connection point recognition for local identification of the
device based on the connection point ID
• Fast system availability after plugging into the connection
boxes
• Connection to the controller and power supply is made via the
connection box and the connecting cable

2/44

Siemens ST 80 / ST PC · 2013

SIMATIC Mobile Panel 277(F) IWLAN
• Wireless, mobile operator panel for flexible and locationindependent system and machine operation
• WLAN communication in accordance with
IEEE 802.11 (a/b/g/h) and PROFINET support
• Powerful batteries and flexible concept for changing permit
battery replacement "on the fly" without interrupting operation
• Effective range limitation and the local identification of the
device by using transponder technology
• Low-cost, safety-related mobile operator control and
monitoring via RFID technology (MOBY D) for plants with
pre-installed safety resources (e.g. robot cells)
• Optional variants with: Handwheel, key switch and illuminated
pushbutton
• Fail-safe operator controls of the
SIMATIC Mobile Panel 277F IWLAN using PROFIsafe:
- Two three-stage acknowledgment buttons
- Emergency stop button
IWLAN Access Points SCALANCE W for
SIMATIC Mobile Panel 277(F) IWLAN
• The Access Points of the product line SCALANCE W-780 are
ideally suited for setting up Industrial Wireless LAN (IWLAN)
radio networks for 2.4 GHz and 5 GHz with data rates of up to
54 Mbps; they can be used for all applications that require a
high degree of operational reliability, even under extremely
harsh ambient conditions
• Suitable for any application:
- SCALANCE W-788 for cabinet-free installation
- SCALANCE W-786 for cabinet-free installation, also with
integral antennas
- SCALANCE W-784 for installation in control cabinets or
integration into devices
• Wireless communication suitable for use in applications with
high real-time and reliability requirements, such as PROFINET,
PROFIsafe or video
• Standard-compliant thanks to IEEE 802.11 support, additional
functional expansions especially for use with increased
reliability
• Effective encryption mechanisms protect against
unauthorized access, spying, tapping, and corruption
• The SINEMA E engineering tool, wizards and online help
support planning, simulation, configuration and documentation; easy management with the web server and SNMP
• Fast commissioning of the Access Points thanks to the
optional swap medium PRESET-PLUG and fast device
replacement in the event of a fault thanks to the optional swap
medium C-PLUG (Configuration Plug)
• Accessories such as antennas, connectors, cables incl.
RCoax cables (radiating cables) that are tuned to one another
for a reliable radio link.

© Siemens AG 2013

Operator panels
Mobile Panels — 170 series
SIMATIC Mobile Panel 177

■ Overview

2

SIMATIC Mobile Panel 177

■ Technical specifications
6AV6645-0AA01-0AX0

6AV6645-0AB01-0AX0

6AV6645-0AC01-0AX0

with integrated acknowledgment
button

with integrated acknowledgment
button and STOP button

with integrated acknowledgment
button, STOP button, handwheel,
keyswitch and illuminated pushbutton

Display
Size

5.7" (121 mm x 92 mm)

5.7" (121 mm x 92 mm)

5.7" (121 mm x 92 mm)

Display type

STN, 256 colors

STN, 256 colors

STN, 256 colors

Resolution (pixels)
• Resolution (WxH in pixel)

320 x 240

320 x 240

320 x 240

Backlighting
• MTBF backlighting (at 25 °C)
• MTBF backlighting (at 25 °C)

about 50,000 hours
50 000 h

about 50,000 hours
50 000 h

about 50,000 hours
50 000 h

Control elements
Operating options

Keys and Touch

Keys and Touch

Keys and Touch

Function keys, programmable

14 function keys, 8 with LEDs

14 function keys, 8 with LEDs

14 function keys, 8 with LEDs

Keyboard fonts
• System keys

0

0

0

Touch operation
• Touch screen

Analog, resistive

Analog, resistive

Analog, resistive

Special operator controls
• Stop button
• Acknowledgement button
• Key-operated switch
• Illuminated pushbutton
• Handwheel

No
Yes
No
No
No

Yes
Yes
No
No
No

Yes
Yes
Yes
Yes
Yes

Supply voltage
Supply voltage

via connection box

via connection box

via connection box

Processor
Processor

RISC 32-bit, 200 MHz

RISC 32-bit, 200 MHz

RISC 32-bit, 200 MHz

Memory
Type

Flash / RAM

Flash / RAM

Flash / RAM

2048 KB of usable memory for
user data / no user memory for options

2048 KB of usable memory for
user data / no user memory for options

2048 KB of usable memory for
user data / no user memory for options

maximum buffer time 10 min

maximum buffer time 10 min

maximum buffer time 10 min

Usable memory for user data
Battery
Backup battery
• Battery operation

Siemens ST 80 / ST PC · 2013

2/45

© Siemens AG 2013

Operator panels
Mobile Panels — 170 series
SIMATIC Mobile Panel 177

■ Technical specifications (continued)

2

6AV6645-0AA01-0AX0

6AV6645-0AB01-0AX0

6AV6645-0AC01-0AX0

with integrated acknowledgment
button

with integrated acknowledgment
button and STOP button

with integrated acknowledgment
button, STOP button, handwheel,
keyswitch and illuminated pushbutton

Interfaces
Interfaces

1 x RS422, 1 x RS485 (max. 12 Mbit/s)

1 x RS422, 1 x RS485 (max. 12 Mbit/s)

1 x RS422, 1 x RS485 (max. 12 Mbit/s)

USB port

No

No

No

Number of USB interfaces

0

0

0

PC card slot

No

No

No

CF card slot

No

No

No

SD card slot

No

Multimedia card/SD card slot

combined

combined

combined

Industrial Ethernet
• Industrial Ethernet interface

No

No

No

Degree and class of
protection
IP65 enclosure

Yes

Yes

Yes

Standards, approvals,
certificates
Certifications

CE, cULus, C-TICK, SIBE

CE, cULus, C-TICK, SIBE

CE, cULus, C-TICK, SIBE

CE

Yes

Yes

Yes

cULus

Yes

Yes

Yes

C-TICK

Yes

Safety category according to
EN954-1

Safety category according to EN954-1
(acknowledgment button, STOP button
if present) 3

Safety category according to EN954-1
(acknowledgment button, STOP button
if present) 3

Safety category according to EN954-1
(acknowledgment button, STOP button
if present) 3

d

d

d

Ambient conditions
Drop height

1.5 m

1.5 m

1.5 m

Operating temperature
• Operation

0 °C to +40 °C

0 °C to +40 °C

0 °C to +40 °C

Storage/transport temperature
• Transport, storage

-20 °C to +60 °C

-20 °C to +60 °C

-20 °C to +60 °C

Relative humidity
• max. relative humidity

80 %

80 %

80 %

Operating systems
Operating system

Windows CE

Windows CE

Windows CE

5

5

5

Functionality under WinCC
(TIA Portal)
Libraries

Yes

Yes

Yes

Task planner

Yes

Yes

Yes

With alarm logging system (incl.
buffer and acknowledgment)
• Number of messages
• Bit messages
• Analog messages

2 000
Yes
Yes

2 000
Yes
Yes

2 000
Yes
Yes

Recipes
• Number of recipes
• Data records per recipe
• Entries per data record
• Recipe memory

100
200
200
32 KB integrated Flash, expandable

100
200
200
32 KB integrated Flash, expandable

100
200
200
32 KB integrated Flash, expandable

Highest safety class achievable
in safety mode
• Performance Level in accordance with EN ISO 13849-1

Languages
Online languages
• Number of online/runtime
languages

2/46

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
Mobile Panels — 170 series
SIMATIC Mobile Panel 177

■ Technical specifications (continued)

Variables
• Number of variables per
device
• Limit values
• Multiplexing

6AV6645-0AA01-0AX0

6AV6645-0AB01-0AX0

6AV6645-0AC01-0AX0

with integrated acknowledgment
button

with integrated acknowledgment
button and STOP button

with integrated acknowledgment
button, STOP button, handwheel,
keyswitch and illuminated pushbutton

1 024

1 024

1 024

Yes
Yes

Yes
Yes

Yes
Yes

500

500

500

2,500 text elements
Bit maps, vector graphics

2,500 text elements
Bit maps, vector graphics

2,500 text elements
Bit maps, vector graphics

With SIMATIC S7
Diagrams, bar graphs, sliders, invisible
buttons

With SIMATIC S7
Diagrams, bar graphs, sliders, invisible
buttons

With SIMATIC S7
Diagrams, bar graphs, sliders, invisible
buttons

300

300

300

100

100

100

0

0

0

Security
• Number of user groups
• Number of user rights
• Password export/import

50
32
Yes

50
32
Yes

50
32
Yes

Data carrier support
• PC card
• CF card

No
No

No
No

No
No

Logging through printer
• Recording/Printing

-

-

-

MPI/PROFIBUS DP, serial, automatic
transfer recognition

MPI/PROFIBUS DP, serial, automatic
transfer recognition

MPI/PROFIBUS DP, serial, automatic
transfer recognition

• S7-1200
• S7-1500

S5, S7-200, S7- 300/400, TI 505,
Win AC, SINUMERIK, SIMOTION, Allen
Bradley (DF1), Allen Bradley (DF485),
Mitsubishi (FX), OMRON (LINK/Multilink), Modicon (Modbus),
further non-Siemens drivers,
see chapter "System interfaces"
Yes
Yes

S5, S7-200, S7- 300/400, TI 505,
Win AC, SINUMERIK, SIMOTION, Allen
Bradley (DF1), Allen Bradley (DF485),
Mitsubishi (FX), OMRON (LINK/Multilink), Modicon (Modbus),
further non-Siemens drivers,
see chapter "System interfaces"
Yes
Yes

S5, S7-200, S7- 300/400, TI 505,
Win AC, SINUMERIK, SIMOTION, Allen
Bradley (DF1), Allen Bradley (DF485),
Mitsubishi (FX), OMRON (LINK/Multilink), Modicon (Modbus),
further non-Siemens drivers,
see chapter "System interfaces"
Yes
Yes

Expandability/openness
• Open Platform Program

Yes

Yes

Yes

I/O
I/O devices
• Multi Media Card

Yes

Yes

Yes

Mechanics/material
Type of housing (front)

Plastic

Plastic

Plastic

Dimensions
Housing diameter/depth (mm)

Dia 245 mm / D 58 mm

Dia 245 mm / D 58 mm

Dia 245 mm / D 58 mm

Weight
Weight

1.3 kg

1.3 kg

1.3 kg

Images
• Number of configurable
images
Image objects
• Text objects
• Graphics object
Complex image objects
• Status/control
• dynamic objects
Lists
• Number of text lists per
project
• Number of graphics lists per
project
Archiving
• Number of archives per
device

Transfer (upload/download)
• Transfer of configuration
Process coupling
• Connection to controller

Siemens ST 80 / ST PC · 2013

2

2/47

© Siemens AG 2013

Operator panels
Mobile Panels — 170 series
SIMATIC Mobile Panel 177

■ Technical specifications (continued)

2

6AV6645-0BA01-0AX0

6AV6645-0BB01-0AX0

6AV6645-0BC01-0AX0

with integrated acknowledgment
button

with integrated acknowledgment
button and STOP button

with integrated acknowledgment
button, STOP button, handwheel,
keyswitch and illuminated pushbutton

Display
Size

5.7" (121 mm x 92 mm)

5.7" (121 mm x 92 mm)

5.7" (121 mm x 92 mm)

Display type

STN, 256 colors

STN, 256 colors

STN, 256 colors

Resolution (pixels)
• Resolution (WxH in pixel)

320 x 240

320 x 240

320 x 240

Backlighting
• MTBF backlighting (at 25 °C)
• MTBF backlighting (at 25 °C)

about 50,000 hours
50 000 h

about 50,000 hours
50 000 h

about 50,000 hours
50 000 h

Control elements
Operating options

Keys and Touch

Keys and Touch

Keys and Touch

Function keys, programmable

14 function keys, 8 with LEDs

14 function keys, 8 with LEDs

14 function keys, 8 with LEDs

Keyboard fonts
• System keys

0

0

0

Touch operation
• Touch screen

Analog, resistive

Analog, resistive

Analog, resistive

Special operator controls
• Stop button
• Acknowledgement button
• Key-operated switch
• Illuminated pushbutton
• Handwheel

No
Yes
No
No
No

Yes
Yes
No
No
No

Yes
Yes
Yes
Yes
Yes

Supply voltage
Supply voltage

via connection box

via connection box

via connection box

Processor
Processor

RISC 32-bit, 200 MHz

RISC 32-bit, 200 MHz

RISC 32-bit, 200 MHz

Memory
Type

Flash / RAM

Flash / RAM

Flash / RAM

2048 KB of usable memory for user
data / no user memory for options

2048 KB of usable memory for user
data / no user memory for options

2048 KB of usable memory for user
data / no user memory for options

Battery
Backup battery
• Battery operation

maximum buffer time 10 min

maximum buffer time 10 min

maximum buffer time 10 min

Interfaces
Interfaces

1 x RS485, 1 x Ethernet (RJ45)

1 x RS485, 1 x Ethernet (RJ45)

1 x RS485, 1 x Ethernet (RJ45)

USB port

No

No

No

Number of USB interfaces

0

0

0

PC card slot

No

No

No

CF card slot

No

No

No

Multimedia card/SD card slot

combined

combined

combined

Industrial Ethernet
• Industrial Ethernet interface

1 x Ethernet (RJ45)

1 x Ethernet (RJ45)

1 x Ethernet (RJ45)

Protocols
PROFINET

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Usable memory for user data

Supports protocol for
PROFINET IO
Degree and class of
protection
IP65 enclosure

2/48

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
Mobile Panels — 170 series
SIMATIC Mobile Panel 177

■ Technical specifications (continued)
6AV6645-0BA01-0AX0

6AV6645-0BB01-0AX0

6AV6645-0BC01-0AX0

with integrated acknowledgment
button

with integrated acknowledgment
button and STOP button

with integrated acknowledgment
button, STOP button, handwheel,
keyswitch and illuminated pushbutton

Standards, approvals,
certificates
Certifications

CE, cULus, C-TICK, SIBE

CE, cULus, C-TICK, SIBE

CE, cULus, C-TICK, SIBE

CE

Yes

Yes

Yes

cULus

Yes

Yes

Yes

Safety category according to
EN954-1

Safety category according to EN954-1
(acknowledgment button, STOP button
if present) 3

Safety category according to EN954-1
(acknowledgment button, STOP button
if present) 3

Safety category according to EN954-1
(acknowledgment button, STOP button
if present) 3

d

d

d

Ambient conditions
Drop height

1.5 m

1.5 m

1.5 m

Operating temperature
• Operation

0 °C to +40 °C

0 °C to +40 °C

0 °C to +40 °C

Storage/transport temperature
• Transport, storage

-20 °C to +60 °C

-20 °C to +60 °C

-20 °C to +60 °C

Relative humidity
• max. relative humidity

80 %

80 %

80 %

Operating systems
Operating system

Windows CE

Windows CE

Windows CE

5

5

5

Functionality under WinCC
(TIA Portal)
Libraries

Yes

Yes

Yes

Task planner

Yes

Yes

Yes

With alarm logging system (incl.
buffer and acknowledgment)
• Number of messages
• Bit messages
• Analog messages

2 000
Yes
Yes

2 000
Yes
Yes

2 000
Yes
Yes

Recipes
• Number of recipes
• Data records per recipe
• Entries per data record
• Recipe memory

100
200
200
32 KB integrated Flash, expandable

100
200
200
32 KB integrated Flash, expandable

100
200
200
32 KB integrated Flash, expandable

1 024

1 024

1 024

Yes
Yes

Yes
Yes

Yes
Yes

500

500

500

2,500 text elements
Bit maps, vector graphics

2,500 text elements
Bit maps, vector graphics

2,500 text elements
Bit maps, vector graphics

With SIMATIC S7
Diagrams, bar graphs, sliders, invisible
buttons

With SIMATIC S7
Diagrams, bar graphs, sliders, invisible
buttons

With SIMATIC S7
Diagrams, bar graphs, sliders, invisible
buttons

Highest safety class achievable
in safety mode
• Performance Level in accordance with EN ISO 13849-1

Languages
Online languages
• Number of online/runtime
languages

Variables
• Number of variables per
device
• Limit values
• Multiplexing
Images
• Number of configurable
images
Image objects
• Text objects
• Graphics object
Complex image objects
• Status/control
• dynamic objects

Siemens ST 80 / ST PC · 2013

2

2/49

© Siemens AG 2013

Operator panels
Mobile Panels — 170 series
SIMATIC Mobile Panel 177

■ Technical specifications (continued)

2

Lists
• Number of text lists
per project
• Number of graphics lists
per project

6AV6645-0BA01-0AX0

6AV6645-0BB01-0AX0

6AV6645-0BC01-0AX0

with integrated acknowledgment
button

with integrated acknowledgment
button and STOP button

with integrated acknowledgment
button, STOP button, handwheel,
keyswitch and illuminated pushbutton

300

300

300

100

100

100

0

0

0

Security
• Number of user groups
• Number of user rights
• Password export/import

50
32
Yes

50
32
Yes

50
32
Yes

Data carrier support
• PC card
• CF card

No
No

No
No

No
No

Logging through printer
• Recording/Printing

-

-

-

Serial, Ethernet, automatic transfer
recognition

Serial, Ethernet, automatic transfer
recognition

Serial, Ethernet, automatic transfer
recognition

• S7-1200
• S7-1500

S7-200, S7- 300/400, Win AC, PC
(TCP/IP), SIMOTION, Modicon
(Modbus), see the chapter "System
interfaces"
Yes
Yes

S7-200, S7- 300/400, Win AC, PC
(TCP/IP), SIMOTION, Modicon
(Modbus), see the chapter "System
interfaces"
Yes
Yes

S7-200, S7- 300/400, Win AC, PC
(TCP/IP), SIMOTION, Modicon
(Modbus), see the chapter "System
interfaces"
Yes
Yes

Expandability/openness
• Open Platform Program

Yes

Yes

Yes

I/O
I/O devices
• Multi Media Card

Printer
Yes

Printer
Yes

Printer
Yes

Mechanics/material
Type of housing (front)

Plastic

Plastic

Plastic

Dimensions
Housing diameter/depth (mm)

Dia 245 mm / D 58 mm

Dia 245 mm / D 58 mm

Dia 245 mm / D 58 mm

Weight
Weight

1.3 kg

1.3 kg

1.3 kg

Archiving
• Number of archives
per device

Transfer (upload/download)
• Transfer of configuration
Process coupling
• Connection to controller

2/50

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
Mobile Panels — 170 series
SIMATIC Mobile Panel 177

SIMATIC Mobile Panel 177 PN
(PROFINET) 1)
• With integrated acknowledgement
button
• With integrated acknowledgement
button and STOP button
• With integrated acknowledgement
button, STOP button, handwheel,
key-operated switch and
illuminated pushbutton

Order No.

6AV6645-0AA01-0AX0

■ Dimensional drawings
All dimensions in mm. For installation cutout, see technical
specifications.

6AV6645-0AB01-0AX0

123.9

6AV6645-0AC01-0AX0

7.80

2

6AV6645-0BA01-0AX0

121.7
6AV6645-0BB01-0AX0

245

SIMATIC Mobile Panel 177 DP
(MPI/PROFIBUS) 1)
• With integrated acknowledgement
button
• With integrated acknowledgement
button and STOP button
• With integrated acknowledgement
button, STOP button, handwheel,
key-operated switch and
illuminated pushbutton

92.3

■ Ordering data

6AV6645-0BC01-0AX0

You can find the manuals for the
Mobile Panels on the Internet at:
http://support.automation.siemens.com/WW/view/en/11599011/
133300
SIMATIC HMI Manual Collection
Electronic documentation on DVD,
5 languages (English, German,
French, Italian and Spanish); contains: all currently available user
manuals, device manuals and
communication manuals for
SIMATIC HMI

61.3
6AV6691-1SA01-0AX0

G_ST80_XX_00046

Documentation

Mobile Panel 177, front and side view

■ More information

System components for
Mobile Panels

Additional information is available in the Internet under:
http://www.siemens.com/simatic-mobile-panels

DP connection box for
Mobile Panels
(MPI/PROFIBUS)
• Basic
• Plus

Note
6AV6671-5AE00-0AX0
6AV6671-5AE10-0AX0

PN connection box for
Mobile Panel (PROFINET)
• Basic
• Plus

6AV6671-5AE01-0AX0
6AV6671-5AE11-0AX0

Connecting cable and
accessories for Mobile Panels

See HMI accessories,
from page 2/99

1)

The system components (connecting cables and connection boxes) must
be ordered separately.

2)

Delivery time approximately 6 weeks

Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about additional sector-specific
products that can be ordered as well as about options for
customer-specific modification and adaptation.

Siemens ST 80 / ST PC · 2013

2/51

© Siemens AG 2013

Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277

■ Overview

2

SIMATIC Mobile Panel 277 10"

SIMATIC Mobile Panel 277 8"

■ Technical specifications
6AV6645-0CA01-0AX0

6AV6645-0CB01-0AX0

6AV6645-0CC01-0AX0

6AV6645-0BE02-0AX0

8" with integrated
acknowledgment button

8" with integrated
acknowledgment button
and STOP button

8" with integrated
acknowledgment button,
STOP button, handwheel,
keyswitch and illuminated
pushbutton

10" with integrated
acknowledgment button
and STOP button

Display
Size

7.5"

7.5"

7.5"

10.4"

Display type

TFT, 65536 colors

TFT, 65536 colors

TFT, 65536 colors

TFT, 65536 colors

Resolution (pixels)
• Resolution (WxH in pixel)

640 x 480

640 x 480

640 x 480

800 x 600

Backlighting
• MTBF backlighting (at 25 °C)
• MTBF backlighting (at 25 °C)

about 50,000 hours
50 000 h

about 50,000 hours
50 000 h

about 50,000 hours
50 000 h

about 50,000 hours
50 000 h

Control elements
Operating options

Keys and Touch

Keys and Touch

Keys and Touch

Touch

Function keys, programmable

18 function keys, 18 with
LEDs

18 function keys, 18 with
LEDs

18 function keys, 18 with
LEDs

none

Connection for mouse/
keyboard/barcode reader

USB / USB / USB

USB / USB / USB

USB / USB / USB

USB / USB / USB

Keyboard fonts
• System keys

0

Touch operation
• Touch screen

Analog, resistive

Analog, resistive

Analog, resistive

Analog, resistive

Special operator controls
• Stop button
• Acknowledgement button
• Key-operated switch
• Illuminated pushbutton

No
Yes
No
No

Yes
Yes
No
No

Yes
Yes
No
No

• Handwheel

No

No

Yes
Yes
Yes
Yes; Two illuminated
pushbuttons
Yes

2/52

Siemens ST 80 / ST PC · 2013

No

© Siemens AG 2013

Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277

■ Technical specifications (continued)
6AV6645-0CA01-0AX0

6AV6645-0CB01-0AX0

6AV6645-0CC01-0AX0

6AV6645-0BE02-0AX0

8" with integrated
acknowledgment button

8" with integrated
acknowledgment button
and STOP button

8" with integrated
acknowledgment button,
STOP button, handwheel,
keyswitch and illuminated
pushbutton

10" with integrated
acknowledgment button
and STOP button

Supply voltage
Supply voltage

via connection box

via connection box

via connection box

via connection box, DC

Processor
Processor

ARM, 520 MHz

ARM, 520 MHz

ARM, 520 MHz

ARM, 520

Memory
Type

Flash / RAM

Flash / RAM

Flash / RAM

Flash / RAM

6 MB usable memory for user
data

6 MB usable memory for user
data

6 MB usable memory for user
data

6 MB usable memory for user
data

maximum buffer time 10 min

maximum buffer time 10 min

maximum buffer time 10 min

maximum buffer time 10 min
5h
500

Hardware clock, battery
backup, synchronizable

Hardware clock, battery
backup, synchronizable

Hardware clock, battery
backup, synchronizable

Hardware clock, battery
backup, synchronizable

1 x RS422, 1 x RS485,
1 x Ethernet (RJ45)
(max. 12 Mbit/s)

1 x RS422, 1 x RS485,
1 x Ethernet (RJ45)
(max. 12 Mbit/s)

1 x RS422, 1 x RS485,
1 x Ethernet (RJ45)
(max. 12 Mbit/s)

1 x RS422, 1 x RS485,
1 x Ethernet (RJ45)
(max. 12 Mbit/s)

USB port

1 x USB

1 x USB

1 x USB

1 x USB

Multi Media Card slot

1 MMC/SD card slot

1 MMC/SD card slot

1 MMC/SD card slot

Usable memory for user data
Battery
Backup battery
• Battery operation
- Charging duration
- Number of loading cycles,
min
Time of day
Clock
• Type
Interfaces
Interfaces

Multimedia card/SD card slot

combined

Industrial Ethernet
• Industrial Ethernet interface

1 x Ethernet (RJ45)

1 x Ethernet (RJ45)

1 x Ethernet (RJ45)

1 x Ethernet (RJ45)

Protocols
PROFINET

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Degree and class of
protection
IP65 enclosure

Yes

Yes

Yes

Yes

Standards, approvals,
certificates
Certifications

CE, cULus, C-TICK, SIBE

CE, cULus, C-TICK, SIBE

CE, cULus, C-TICK, SIBE

CE, cULus, C-TICK, SIBE

Safety category according to
EN954-1 (acknowledgment
button, STOP button if present) 3

Safety category according to
EN954-1 (acknowledgment
button, STOP button if present) 3

Safety category according to
EN954-1 (acknowledgment
button, STOP button if present) 3

Safety category according to
EN954-1 (acknowledgment
button, STOP button if present) 3

d

d

d

d

Supports protocol for
PROFINET IO

Safety category according to
EN954-1

Highest safety class achievable
in safety mode
• Performance Level in accordance with EN ISO 13849-1

Siemens ST 80 / ST PC · 2013

2/53

2

© Siemens AG 2013

Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277

■ Technical specifications (continued)

2

6AV6645-0CA01-0AX0

6AV6645-0CB01-0AX0

6AV6645-0CC01-0AX0

6AV6645-0BE02-0AX0

8" with integrated
acknowledgment button

8" with integrated
acknowledgment button
and STOP button

8" with integrated
acknowledgment button,
STOP button, handwheel,
keyswitch and illuminated
pushbutton

10" with integrated
acknowledgment button
and STOP button

Ambient conditions
Drop height

1.2 m

1.2 m

1.2 m

1m

Operating temperature
• Operation

0 °C to +40 °C

0 °C to +40 °C

0 °C to +40 °C

0 °C to +40 °C

Storage/transport temperature
• Transport, storage

-20 °C to +60 °C

-20 °C to +60 °C

-20 °C to +60 °C

-20 °C to +60 °C

Relative humidity
• max. relative humidity

80 %

80 %

80 %

80 %

Operating systems
Operating system

Windows CE

Windows CE

Windows CE

Windows CE

16

16

16

16

Functionality under WinCC
(TIA Portal)
Libraries

Yes

Yes

Yes

Yes

Task planner

Yes

Yes

Yes

Yes

With alarm logging system (incl.
buffer and acknowledgment)
• Number of messages
• Bit messages
• Analog messages

4 000
Yes
Yes

4 000
Yes
Yes

4 000
Yes
Yes

4 000
Yes
Yes

300
500
1 000
64 KB integrated Flash,
expandable

300
500
1 000
64 KB integrated Flash,
expandable

300
500
1 000
64 KB integrated Flash,
expandable

300
200
1 000
64 KB integrated Flash,
expandable

2 048

2 048

2 048

2 048

Yes
Yes

Yes
Yes

Yes
Yes

Yes
Yes

500

500

500

500

10,000 text elements
Bit maps, icons, vector
graphics

10,000 text elements
Bit maps, icons, vector
graphics

10,000 text elements
Bit maps, icons, vector
graphics

10,000 text elements
Bit maps, icons, vector
graphics

With SIMATIC S7
Diagrams, bar graphs,
sliders, analog display,
invisible buttons

With SIMATIC S7
Diagrams, bar graphs,
sliders, analog display,
invisible buttons

With SIMATIC S7
Diagrams, bar graphs,
sliders, analog display,
invisible buttons

With SIMATIC S7
Diagrams, bar graphs,
sliders, analog display,
invisible buttons

Languages
Online languages
• Number of online/runtime
languages

Recipes
• Number of recipes
• Data records per recipe
• Entries per data record
• Recipe memory
Variables
• Number of variables
per device
• Limit values
• Multiplexing
Images
• Number of configurable
images
Image objects
• Text objects
• Graphics object
Complex image objects
• Status/control
• dynamic objects

2/54

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277

■ Technical specifications (continued)
6AV6645-0CA01-0AX0

6AV6645-0CB01-0AX0

6AV6645-0CC01-0AX0

6AV6645-0BE02-0AX0

8" with integrated
acknowledgment button

8" with integrated
acknowledgment button
and STOP button

8" with integrated
acknowledgment button,
STOP button, handwheel,
keyswitch and illuminated
pushbutton

10" with integrated
acknowledgment button
and STOP button

500

500

500

500

400

400

400

400

20

20

20

20

20

20

20

20

10 000

10 000

10 000

10 000

50
32
Yes

50
32
Yes

50
32
Yes

50
32
Yes

Alarms, report (shift report),
color print, hardcopy

Alarms, report (shift report),
color print, hardcopy

Alarms, report (shift report),
color print, hardcopy

Alarms, report (shift report),
color print, hardcopy,
PROFINET

MPI/PROFIBUS DP, USB,
Ethernet, automatic transfer
recognition

MPI/PROFIBUS DP, USB,
Ethernet, automatic transfer
recognition

MPI/PROFIBUS DP, USB,
Ethernet, automatic transfer
recognition

MPI/PROFIBUS DP, USB,
Ethernet, automatic transfer
recognition

• S7-1200
• S7-1500

S5, S7-200, S7-300/400,
TI 505, Win AC, PC (TCP/IP),
SINUMERIK, SIMOTION,
Allen Bradley (DF1), Allen
Bradley (DF485), Mitsubishi
(FX), OMRON (LINK/Multilink), Modicon (Modbus),
further non-Siemens drivers,
see chapter "System interfaces"
Yes
Yes

S5, S7-200, S7- 300/400,
TI 505, SINUMERIK,
SIMOTION, Allen Bradley
(DF1), Allen Bradley (DF485),
Mitsubishi (FX), OMRON
(LINK/Multilink), Modicon
(Modbus),
further non-Siemens drivers,
see chapter "System interfaces"
Yes
Yes

S5, S7-200, S7- 300/400,
TI 505, SINUMERIK,
SIMOTION, Allen Bradley
(DF1), Allen Bradley (DF485),
Mitsubishi (FX), OMRON
(LINK/Multilink), Modicon
(Modbus),
further non-Siemens drivers,
see chapter "System interfaces"
Yes
Yes

S5, S7-200, S7- 300/400,
TI 505, Win AC, SINUMERIK,
SIMOTION, Allen Bradley
(DF1), Allen Bradley (DF485),
Mitsubishi (FX), OMRON
(LINK/Multilink), Modicon
(Modbus),
further non-Siemens drivers,
see chapter "System interfaces"
Yes
Yes

I/O
I/O devices
• Multi Media Card

Printer, barcode reader
Yes

Printer, barcode reader
Yes

Printer, barcode reader
Yes

Printer, barcode reader
Yes

Mechanics/material
Type of housing (front)

Plastic

Plastic

Plastic

Plastic

Dimensions
Housing diameter/depth (mm)

Dia 290 mm / D 103 mm

Dia 290 mm / D 103 mm

Dia 290 mm / D 103 mm

Weight
Weight

1.7 kg

1.7 kg

1.7 kg

Lists
• Number of text lists per
project
• Number of graphics lists per
project
Archiving
• Number of archives per
device
• Number of measuring points
per project
• Number of entries per archive
Security
• Number of user groups
• Number of user rights
• Password export/import
Logging through printer
• Recording/Printing

Transfer (upload/download)
• Transfer of configuration

Process coupling
• Connection to controller

2

2.3 kg

Siemens ST 80 / ST PC · 2013

2/55

© Siemens AG 2013

Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277

■ Ordering data

SIMATIC Mobile Panel 277 10"
• With integrated acknowledgement
button and STOP button

Order No.
6AV6645-0CA01-0AX0

■ Dimensional drawings
All dimensions in mm. For installation cutout, see technical
specifications.

6AV6645-0CB01-0AX0
6AV6645-0CC01-0AX0

8°

6AV6645-0BE02-0AX0

Documentation

9
155

6AV6691-1SA01-0AX0

5 languages (English, French,
German, Italian and Spanish);
contains: all currently available user
manuals, device manuals and
communication manuals for
SIMATIC HMI

103
Ø 290

129

System components
for Mobile Panels
DP connection box for
Mobile Panels (MPI/PROFIBUS)
• Basic
• Plus

6AV6671-5AE00-0AX0
6AV6671-5AE10-0AX0

PN connection box for
Mobile Panel (PROFINET)
• Basic
• Plus

6AV6671-5AE01-0AX0
6AV6671-5AE11-0AX0

Connecting cable and
accessories for Mobile Panels

See HMI accessories,
from page 2/99

G_ST80_XX_00277

SIMATIC HMI Manual Collection
Electronic documentation, on DVD

117

You can find the manuals for the
Mobile Panels on the Internet at:
http://support.automation.siemens.com/WW/view/en/11599011/
133300

Mobile Panel 277 8", front and side view

1)

The system components (connecting cables and connection boxes) must
be ordered separately.

2)

Delivery time approximately 6 weeks

320

8°

212
159

103
350

129

G_ST80_XX_00354

2

SIMATIC Mobile Panel 277 8" 1)
• With integrated acknowledgement
button
• With integrated acknowledgement
button and STOP button
• With integrated acknowledgement
button, STOP button, handwheel,
key-operated switch and two illuminated pushbuttons

Mobile Panel 277 10", front and side view

■ More information
Additional information is available in the Internet under:
http://www.siemens.com/simatic-mobile-panels
Note
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about additional sector-specific
products that can be ordered as well as about options for
customer-specific modification and adaptation.

2/56

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277(F) IWLAN

■ Overview

2

SIMATIC Mobile Panel 277(F) IWLAN

■ Technical specifications
6AV6645-0DD01-0AX1

6AV6645-0DE01-0AX1

6AV6645-0EB01-0AX1

6AV6645-0EC01-0AX1

6AV6645-0EF01-0AX1
RFID TAG

with integrated
handwheel,
keyoperated switch
and two illuminated
pushbuttons

with integrated
acknowledgement
button and emergency
stop button

with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons

with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons

Display
Size

7.5"

7.5"

7.5"

7.5"

7.5"

Display type

TFT, 65536 colors

TFT, 65536 colors

TFT, 65536 colors

TFT, 65536 colors

TFT, 65536 colors

640 x 480

640 x 480

640 x 480

640 x 480

about 50,000 hours

about 50,000 hours

about 50,000 hours

about 50,000 hours

about 50,000 hours

50 000 h

50 000 h

50 000 h

50 000 h

50 000 h

Control elements
Operating options

Keys and Touch

Keys and Touch

Keys and Touch

Keys and Touch

Keys and Touch

Function keys,
programmable

18 function keys,
18 with LEDs

18 function keys,
18 with LEDs

18 function keys,
18 with LEDs

18 function keys,
18 with LEDs

18 function keys,
18 with LEDs

Connection for mouse/
keyboard/barcode reader

USB / USB / USB

USB / USB / USB

USB / USB / USB

USB / USB / USB

USB / USB / USB

Analog, resistive

Analog, resistive

Analog, resistive

Analog, resistive

Analog, resistive

No
No

No
No

Yes
Yes

Yes
Yes

Yes
Yes

No
No
No

Yes
Yes
Yes

No
No
No

Yes
Yes
Yes

Yes
Yes
Yes

Resolution (pixels)
• Resolution (WxH in pixel) 640 x 480
Backlighting
• MTBF backlighting
(at 25 °C)
• MTBF backlighting
(at 25 °C)

Touch operation
• Touch screen
Special operator controls
• Stop button
• Acknowledgement
button
• Key-operated switch
• Illuminated pushbutton
• Handwheel

Siemens ST 80 / ST PC · 2013

2/57

© Siemens AG 2013

Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277(F) IWLAN

■ Technical specifications (continued)
6AV6645-0DD01-0AX1

6AV6645-0DE01-0AX1

6AV6645-0EB01-0AX1

6AV6645-0EC01-0AX1

6AV6645-0EF01-0AX1
RFID TAG

with integrated
handwheel,
keyoperated switch
and two illuminated
pushbuttons

with integrated
acknowledgement
button and emergency
stop button

with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons

with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons

2
Supply voltage
Supply voltage

DC

DC

DC

DC

DC

Via charging station

Yes

Yes

Yes

Yes

Yes

Via table power supply

Yes

Yes

Yes

Yes

Yes

Processor
Processor

ARM, 520 MHz

ARM, 520 MHz

ARM, 520 MHz

ARM, 520 MHz

ARM, 520 MHz

Memory
Type

Flash / RAM

Flash / RAM

Flash / RAM

Flash / RAM

Flash / RAM

Usable memory for user
data

6 MB usable memory
for user data

6 MB usable memory
for user data

6 MB usable memory
for user data

6 MB usable memory
for user data

6 MB usable memory
for user data

7.2 V
5 100 mA·h
500

7.2 V
5 100 mA·h
500

7.2 V
5 100 mA·h
500

7.2 V
5 100 mA·h
500

7.2 V
5 100 mA·h
500

4h
4h
Yes

4h
4h
Yes

4h
4h
Yes

4h
4h
Yes

4h
4h
Yes

Yes
Yes

Yes
Yes

Yes
Yes

Yes
Yes

Yes
Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Battery
Main battery
• Rated voltage
• Capacity
• Number of loading
cycles, min
• Charging time, typ.
• Operating time, typ.
• Display for battery
capacity
• Energy-saving mode
• Battery replacement
during operation
Type of output
Status LEDs
LED for safe
LED for communication

Yes

Yes

Yes

Yes

Yes

LED for battery

Yes

Yes

Yes

Yes

Yes

Vibrations

Yes

Yes

Yes

Yes

Yes

Hardware clock, battery
backup, synchronizable

Hardware clock, battery
backup, synchronizable

Hardware clock, battery
backup, synchronizable

Hardware clock, battery
backup, synchronizable

Hardware clock, battery
backup, synchronizable

Interfaces
Interfaces

1 x Ethernet (RJ45)

1 x Ethernet (RJ45)

1 x Ethernet (RJ45)

1 x Ethernet (RJ45)

1 x Ethernet (RJ45)

USB port

1 x USB

1 x USB

1 x USB

1 x USB

1 x USB

Multi Media Card slot

1 MMC/SD card slot

1 MMC/SD card slot

1 MMC/SD card slot

1 MMC/SD card slot

1 MMC/SD card slot

Industrial Ethernet
• Industrial Ethernet
interface

1 x Ethernet (RJ45)

1 x Ethernet (RJ45)

1 x Ethernet (RJ45)

1 x Ethernet (RJ45)

1 x Ethernet (RJ45)

WLAN
• Wireless LAN
• Supports rapid roaming

Yes
Yes

Yes
Yes

Yes
Yes

Yes
Yes

Yes
Yes

Protocols
PROFINET

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Time of day
Clock
• Type

Supports protocol for
PROFINET IO
Supports protocol for
PROFIsafe

2/58

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277(F) IWLAN

■ Technical specifications (continued)
6AV6645-0DD01-0AX1

EMC
Emission of radio interference acc. to EN 55 011
• Emission of radio
interferences acc. to
EN 55 011 (limit class A)

6AV6645-0DE01-0AX1

6AV6645-0EB01-0AX1

6AV6645-0EC01-0AX1

6AV6645-0EF01-0AX1
RFID TAG

with integrated
handwheel,
keyoperated switch
and two illuminated
pushbuttons

with integrated
acknowledgement
button and emergency
stop button

with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons

with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons

Yes; The product is
designed for use in
industrial environments.
When used in residential areas, the emission
of radio interference
according to limit class
B of EN 55011 must be
ensured. For further
information refer to the
user documentation

Yes; The product is
designed for use in
industrial environments.
When used in residential areas, the emission
of radio interference
according to limit class
B of EN 55011 must be
ensured. For further
information refer to the
user documentation

Yes; The product is
designed for use in
industrial environments.
When used in residential areas, the emission
of radio interference
according to limit class
B of EN 55011 must be
ensured. For further
information refer to the
user documentation

Yes; The product is
designed for use in
industrial environments.
When used in residential areas, the emission
of radio interference
according to limit class
B of EN 55011 must be
ensured. For further
information refer to the
user documentation

Yes; The product is
designed for use in
industrial environments.
When used in residential areas, the emission
of radio interference
according to limit class
B of EN 55011 must be
ensured. For further
information refer to the
user documentation

Degree and class of
protection
IP65 enclosure

Yes

Yes

Yes

Yes

Yes

Standards, approvals,
certificates
Certifications

CE, cULus, C-TICK

CE, cULus, C-TICK

CE, cULus, C-TICK

CE, cULus, C-TICK

CE, cULus, C-TICK

TÜV safety certification

Yes

Yes

Yes

Safety category according
to EN954-1

Safety category according to EN954-1
(enabling button, STOP
button if present) 4

Safety category according to EN954-1
(enabling button, STOP
button if present) 4

Safety category according to EN954-1
(enabling button, STOP
button if present) 4

e

e

e

Highest safety class
achievable in safety mode
• Performance Level in
accordance with
EN ISO 13849-1
Ambient conditions
Drop height

1.2 m

1.2 m

1.2 m

1.2 m

1.2 m

Operating temperature
• Operation

0 °C to +40 °C

0 °C to +40 °C

0 °C to +40 °C

0 °C to +40 °C

0 °C to +40 °C

Storage/transport
temperature
• Transport, storage

-20 °C to +60 °C

-20 °C to +60 °C

-20 °C to +60 °C

-20 °C to +60 °C

-20 °C to +60 °C

Relative humidity
• max. relative humidity

80 %

80 %

80 %

80 %

80 %

Operating systems
Operating system

Windows CE

Windows CE

Windows CE

Windows CE

Windows CE

16

16

16

16

16

Functionality under
WinCC (TIA Portal)
Libraries

Yes

Yes

Yes

Yes

Yes

Task planner

Yes

Yes

Yes

Yes

Yes

With alarm logging system
(incl. buffer and acknowledgment)
• Number of messages
• Bit messages
• Analog messages

4 000
Yes
Yes

4 000
Yes
Yes

4 000
Yes
Yes

4 000
Yes
Yes

4 000
Yes
Yes

300
500
1 000
64 KB integrated Flash,
expandable

300
500
1 000
64 KB integrated Flash,
expandable

300
500
1 000
64 KB integrated Flash,
expandable

300
500
1 000
64 KB integrated Flash,
expandable

300
500
1 000
64 KB integrated Flash,
expandable

Languages
Online languages
• Number of online/runtime languages

Recipes
• Number of recipes
• Data records per recipe
• Entries per data record
• Recipe memory

Siemens ST 80 / ST PC · 2013

2/59

2

© Siemens AG 2013

Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277(F) IWLAN

■ Technical specifications (continued)
6AV6645-0DD01-0AX1

6AV6645-0DE01-0AX1

6AV6645-0EB01-0AX1

6AV6645-0EC01-0AX1

6AV6645-0EF01-0AX1
RFID TAG

with integrated
handwheel,
keyoperated switch
and two illuminated
pushbuttons

with integrated
acknowledgement
button and emergency
stop button

with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons

with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons

2 048

2 048

2 048

2 048

2 048

Yes
Yes

Yes
Yes

Yes
Yes

Yes
Yes

Yes
Yes

500

500

500

500

500

10,000 text elements
Bit maps, icons, vector
graphics

10,000 text elements
Bit maps, icons, vector
graphics

10,000 text elements
Bit maps, icons, vector
graphics

10,000 text elements
Bit maps, icons, vector
graphics

10,000 text elements
Bit maps, icons, vector
graphics

With SIMATIC S7
Diagrams, bar graphs,
sliders, analog display,
invisible buttons

With SIMATIC S7
Diagrams, bar graphs,
sliders, analog display,
invisible buttons

With SIMATIC S7
Diagrams, bar graphs,
sliders, analog display,
invisible buttons

With SIMATIC S7
Diagrams, bar graphs,
sliders, analog display,
invisible buttons

With SIMATIC S7
Diagrams, bar graphs,
sliders, analog display,
invisible buttons

500

500

500

500

500

400

400

400

400

400

20

20

20

20

20

20

20

20

20

20

10 000

10 000

10 000

10 000

10 000

50
32
Yes

50
32
Yes

50
32
Yes

50
32
Yes

50
32
Yes

Alarms, report (shift
report), PROFINET

Alarms, report (shift
report), PROFINET

Alarms, report (shift
report), PROFINET

Alarms, report (shift
report), PROFINET

Alarms, report (shift
report), PROFINET

USB, Ethernet, automatic transfer recognition
Yes

USB, Ethernet, automatic transfer recognition
Yes

USB, Ethernet, automatic transfer recognition
Yes

USB, Ethernet, automatic transfer recognition
Yes

USB, Ethernet, automatic transfer recognition
Yes

2
Variables
• Number of variables
per device
• Limit values
• Multiplexing
Images
• Number of configurable
images
Image objects
• Text objects
• Graphics object
Complex image objects
• Status/control
• dynamic objects

Lists
• Number of text lists
per project
• Number of graphics lists
per project
Archiving
• Number of archives
per device
• Number of measuring
points per project
• Number of entries
per archive
Security
• Number of user groups
• Number of user rights
• Password export/import
Logging through printer
• Recording/Printing
Transfer
(upload/download)
• Transfer of configuration

• Wireless LAN

2/60

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277(F) IWLAN

■ Technical specifications (continued)
6AV6645-0DD01-0AX1

Process coupling
• Connection to controller

• S7-1200
• S7-1500
• Zones
- Number of zones
per project, max.
- Number of transponders for zones per
project, max.
• Effective range
- Number of effective
ranges per project,
max.
- Number of
transponders for
effective ranges per
project, max.
• Transponder
- Number of transponders per project, max.
- Adjustable distance
range
- Adjustable distance,
min.
- Adjustable distance,
max.

6AV6645-0DE01-0AX1

6AV6645-0EB01-0AX1

6AV6645-0EC01-0AX1

6AV6645-0EF01-0AX1
RFID TAG

with integrated
handwheel,
keyoperated switch
and two illuminated
pushbuttons

with integrated
acknowledgement
button and emergency
stop button

with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons

with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
S7-200, S7- 300/400
see section on "System
interfaces"
No
No

S7-200, S7- 300/400
see section on "System
interfaces"
Yes
Yes
Yes
254

S7-200, S7- 300/400
see section on "System
interfaces"
Yes
Yes
Yes
254

S7-200, S7- 300/400
see section on "System
interfaces"
No
No
Yes
254

S7-200, S7- 300/400
see section on "System
interfaces"
No
No
Yes
254

255

255

255

255

Yes
127

Yes
127

127

127

Yes
127

Yes
256

Yes
256

Yes
256

Yes
256

Yes

Yes

Yes

Yes

2m

2m

2m

2m

8m

8m

8m

8m

I/O
I/O devices
• Multi Media Card

Barcode reader
Yes

Barcode reader
Yes

Barcode reader
Yes

Barcode reader
Yes

Barcode reader
Yes

Mechanics/material
Type of housing (front)

Plastic

Plastic

Plastic

Plastic

Plastic

Dia 290 mm / D 103 mm Dia 290 mm / D 103 mm

Dia 290 mm / D 103 mm

Dia 290 mm / D 103 mm

Dia 290 mm / D 103 mm

2.2 kg

2.2 kg

2.2 kg

2.2 kg

Dimensions
Housing diameter/depth
(mm)
Weight
Weight

2.2 kg

Siemens ST 80 / ST PC · 2013

2/61

2

© Siemens AG 2013

Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277(F) IWLAN

■ Technical specifications (continued)
6AV6645-0FD01-0AX1

6AV6645-0FE01-0AX1

6AV6645-0GB01-0AX1

6AV6645-0GC01-0AX1

6AV6645-0GF01-0AX1

USA version

USA version
with handwheel,
keyoperated switch
and two illuminated
pushbuttons

USA version
with integrated
acknowledgement
button and emergency
stop button

USA version
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons

USA version
RFID TAG
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons

Display
Size

7.5"

7.5"

7.5"

7.5"

7.5"

Display type

TFT, 65536 colors

TFT, 65536 colors

TFT, 65536 colors

TFT, 65536 colors

TFT, 65536 colors

640 x 480

640 x 480

640 x 480

640 x 480

about 50,000 hours

about 50,000 hours

about 50,000 hours

about 50,000 hours

50 000 h

50 000 h

50 000 h

2

Resolution (pixels)
• Resolution (WxH in pixel) 640 x 480
Backlighting
• MTBF backlighting
(at 25 °C)
• MTBF backlighting
(at 25 °C)

about 50,000 hours
50 000 h

Control elements
Operating options

Keys and Touch

Keys and Touch

Keys and Touch

Keys and Touch

Keys and Touch

Function keys,
programmable

18 function keys,
18 with LEDs

18 function keys,
18 with LEDs

18 function keys,
18 with LEDs

18 function keys,
18 with LEDs

18 function keys,
18 with LEDs

Connection for mouse/
keyboard/barcode reader

USB / USB / USB

USB / USB / USB

USB / USB / USB

USB / USB / USB

USB / USB / USB

Analog, resistive

Analog, resistive

Analog, resistive

Analog, resistive

Analog, resistive

No
No

No
No

Yes
Yes

Yes
Yes

Yes
Yes

No
No
No

Yes
Yes
Yes

No
No
No

Yes
Yes
Yes

Yes
Yes
Yes

Supply voltage
Supply voltage

DC

DC

DC

DC

DC

Via charging station

Yes

Yes

Yes

Yes

Yes

Via table power supply

Yes

Yes

Yes

Yes

Yes

Processor
Processor

ARM, 520 MHz

ARM, 520 MHz

ARM, 520 MHz

ARM, 520 MHz

ARM, 520 MHz

Memory
Type

Flash / RAM

Flash / RAM

Flash / RAM

Flash / RAM

Flash / RAM

Usable memory for user
data

6 MB usable memory
for user data

6 MB usable memory
for user data

6 MB usable memory
for user data

6 MB usable memory
for user data

6 MB usable memory
for user data

7.2 V
5 100 mA·h
500

7.2 V
5 100 mA·h
500

7.2 V
5 100 mA·h
500

7.2 V
5 100 mA·h
500

7.2 V
5 100 mA·h
500

4h
4h
Yes

4h
4h
Yes

4h
4h
Yes

4h
4h
Yes

4h
4h
Yes

Yes
Yes

Yes
Yes

Yes
Yes

Yes
Yes

Yes
Yes

Touch operation
• Touch screen
Special operator controls
• Stop button
• Acknowledgement
button
• Key-operated switch
• Illuminated pushbutton
• Handwheel

Battery
Main battery
• Rated voltage
• Capacity
• Number of loading
cycles, min
• Charging time, typ.
• Operating time, typ.
• Display for battery
capacity
• Energy-saving mode
• Battery replacement
during operation

2/62

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277(F) IWLAN

■ Technical specifications (continued)

Type of output
Status LEDs

6AV6645-0FD01-0AX1

6AV6645-0FE01-0AX1

6AV6645-0GB01-0AX1

6AV6645-0GC01-0AX1

6AV6645-0GF01-0AX1

USA version

USA version
with handwheel,
keyoperated switch
and two illuminated
pushbuttons

USA version
with integrated
acknowledgement
button and emergency
stop button

USA version
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons

USA version
RFID TAG
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

LED for safe
LED for communication

Yes

Yes

Yes

Yes

Yes

LED for battery

Yes

Yes

Yes

Yes

Yes

Vibrations

Yes

Yes

Yes

Yes

Yes

Hardware clock, battery
backup, synchronizable

Hardware clock, battery
backup, synchronizable

Hardware clock, battery
backup, synchronizable

Hardware clock, battery
backup, synchronizable

Hardware clock, battery
backup, synchronizable

Interfaces
Interfaces

1 x Ethernet (RJ45)

1 x Ethernet (RJ45)

1 x Ethernet (RJ45)

1 x Ethernet (RJ45)

1 x Ethernet (RJ45)

USB port

1 x USB

1 x USB

1 x USB

1 x USB

1 x USB

Multi Media Card slot

1 MMC/SD card slot

1 MMC/SD card slot

1 MMC/SD card slot

1 MMC/SD card slot

1 MMC/SD card slot

Industrial Ethernet
• Industrial Ethernet
interface

1 x Ethernet (RJ45)

1 x Ethernet (RJ45)

1 x Ethernet (RJ45)

1 x Ethernet (RJ45)

1 x Ethernet (RJ45)

WLAN
• Wireless LAN
• Supports rapid roaming

Yes
Yes

Yes
Yes

Yes
Yes

Yes
Yes

Yes
Yes

Protocols
PROFINET

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes; The product is
designed for use in
industrial environments.
When used in residential areas, the emission
of radio interference
according to limit class
B of EN 55011 must be
ensured. For further
information refer to the
user documentation

Yes; The product is
designed for use in
industrial environments.
When used in residential areas, the emission
of radio interference
according to limit class
B of EN 55011 must be
ensured. For further
information refer to the
user documentation

Yes; The product is
designed for use in
industrial environments.
When used in residential areas, the emission
of radio interference
according to limit class
B of EN 55011 must be
ensured. For further
information refer to the
user documentation

Time of day
Clock
• Type

Supports protocol for
PROFINET IO
Supports protocol for
PROFIsafe
EMC
Emission of radio interference acc. to EN 55 011
• Emission of radio
interferences acc. to
EN 55 011 (limit class A)

Yes; The product is
designed for use in
industrial environments.
When used in residential areas, the emission
of radio interference
according to limit class
B of EN 55011 must be
ensured. For further
information refer to the
user documentation

Yes; The product is
designed for use in
industrial environments.
When used in residential areas, the emission
of radio interference
according to limit class
B of EN 55011 must be
ensured. For further
information refer to the
user documentation

Siemens ST 80 / ST PC · 2013

2/63

2

© Siemens AG 2013

Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277(F) IWLAN

■ Technical specifications (continued)
6AV6645-0FD01-0AX1

6AV6645-0FE01-0AX1

6AV6645-0GB01-0AX1

6AV6645-0GC01-0AX1

6AV6645-0GF01-0AX1

USA version

USA version
with handwheel,
keyoperated switch
and two illuminated
pushbuttons

USA version
with integrated
acknowledgement
button and emergency
stop button

USA version
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons

USA version
RFID TAG
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons

Degree and class of
protection
IP65 enclosure

Yes

Yes

Yes

Yes

Yes

Standards, approvals,
certificates
Certifications

CE, cULus, C-TICK

CE, cULus, C-TICK

2

CE, cULus, C-TICK

CE, cULus, C-TICK

CE, cULus, C-TICK

TÜV safety certification

Yes

Yes

Yes

Safety category according
to EN954-1

Safety category
according to EN954-1
(enabling button, STOP
button if present) 4

Safety category
according to EN954-1
(enabling button, STOP
button if present) 4

Safety category
according to EN954-1
(enabling button, STOP
button if present) 4

e

e

e

Highest safety class
achievable in safety mode
• Performance Level in
accordance with
EN ISO 13849-1
Ambient conditions
Drop height

1.2 m

1.2 m

1.2 m

1.2 m

1.2 m

Operating temperature
• Operation

0 °C to +40 °C

0 °C to +40 °C

0 °C to +40 °C

0 °C to +40 °C

0 °C to +40 °C

Storage/transport temperature
• Transport, storage

-20 °C to +60 °C

-20 °C to +60 °C

-20 °C to +60 °C

-20 °C to +60 °C

-20 °C to +60 °C

Relative humidity
• max. relative humidity

80 %

80 %

80 %

80 %

80 %

Operating systems
Operating system

Windows CE

Windows CE

Windows CE

Windows CE

Windows CE

16

16

16

16

16

Functionality under
WinCC (TIA Portal)
Libraries

Yes

Yes

Yes

Yes

Yes

Task planner

Yes

Yes

Yes

Yes

Yes

With alarm logging system
(incl. buffer and acknowledgment)
• Number of messages
• Bit messages
• Analog messages

4 000
Yes
Yes

4 000
Yes
Yes

4 000
Yes
Yes

4 000
Yes
Yes

4 000
Yes
Yes

300
500
1 000
64 KB integrated Flash,
expandable

300
500
1 000
64 KB integrated Flash,
expandable

300
500
1 000
64 KB integrated Flash,
expandable

300
500
1 000
64 KB integrated Flash,
expandable

300
500
1 000
64 KB integrated Flash,
expandable

Languages
Online languages
• Number of online/
runtime languages

Recipes
• Number of recipes
• Data records per recipe
• Entries per data record
• Recipe memory

2/64

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277(F) IWLAN

■ Technical specifications (continued)

Variables
• Number of variables per
device
• Limit values
• Multiplexing
Images
• Number of configurable
images
Image objects
• Text objects
• Graphics object
Complex image objects
• Status/control
• dynamic objects

Lists
• Number of text lists per
project
• Number of graphics lists
per project
Archiving
• Number of archives per
device
• Number of measuring
points per project
• Number of entries per
archive
Security
• Number of user groups
• Number of user rights
• Password export/import
Logging through printer
• Recording/Printing
Transfer
(upload/download)
• Transfer of configuration

• Wireless LAN

6AV6645-0FD01-0AX1

6AV6645-0FE01-0AX1

6AV6645-0GB01-0AX1

6AV6645-0GC01-0AX1

6AV6645-0GF01-0AX1

USA version

USA version
with handwheel,
keyoperated switch
and two illuminated
pushbuttons

USA version
with integrated
acknowledgement
button and emergency
stop button

USA version
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons

USA version
RFID TAG
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons

2 048

2 048

2 048

2 048

2 048

Yes
Yes

Yes
Yes

Yes
Yes

Yes
Yes

Yes
Yes

500

500

500

500

500

10,000 text elements
Bit maps, icons, vector
graphics

10,000 text elements
Bit maps, icons, vector
graphics

10,000 text elements
Bit maps, icons, vector
graphics

10,000 text elements
Bit maps, icons, vector
graphics

10,000 text elements
Bit maps, icons, vector
graphics

With SIMATIC S7
Diagrams, bar graphs,
sliders, analog display,
invisible buttons

With SIMATIC S7
Diagrams, bar graphs,
sliders, analog display,
invisible buttons

With SIMATIC S7
Diagrams, bar graphs,
sliders, analog display,
invisible buttons

With SIMATIC S7
Diagrams, bar graphs,
sliders, analog display,
invisible buttons

With SIMATIC S7
Diagrams, bar graphs,
sliders, analog display,
invisible buttons

500

500

500

500

500

400

400

400

400

400

20

20

20

20

20

20

20

20

20

20

10 000

10 000

10 000

10 000

10 000

50
32
Yes

50
32
Yes

50
32
Yes

50
32
Yes

50
32
Yes

Alarms, report (shift
report), PROFINET

Alarms, report (shift
report), PROFINET

Alarms, report (shift
report), PROFINET

Alarms, report (shift
report), PROFINET

Alarms, report (shift
report), PROFINET

USB, Ethernet, automatic transfer recognition
Yes

USB, Ethernet, automatic transfer recognition
Yes

USB, Ethernet, automatic transfer recognition
Yes

USB, Ethernet, automatic transfer recognition
Yes

USB, Ethernet, automatic transfer recognition
Yes

Siemens ST 80 / ST PC · 2013

2/65

2

© Siemens AG 2013

Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277(F) IWLAN

■ Technical specifications (continued)
6AV6645-0FD01-0AX1

6AV6645-0FE01-0AX1

6AV6645-0GB01-0AX1

6AV6645-0GC01-0AX1

6AV6645-0GF01-0AX1

USA version

USA version
with handwheel,
keyoperated switch
and two illuminated
pushbuttons

USA version
with integrated
acknowledgement
button and emergency
stop button

USA version
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons

USA version
RFID TAG
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons

S7-200, S7- 300/400
see section on "System
interfaces"
Yes
Yes
Yes
254

S7-200, S7- 300/400
see section on "System
interfaces"
Yes
Yes
Yes
254

S7-200, S7- 300/400
see section on "System
interfaces"
No
No
Yes
254

S7-200, S7- 300/400
see section on "System
interfaces"
No
No
Yes
254

S7-200, S7- 300/400
see section on "System
interfaces"
No
No

255

255

255

255

Yes
127

Yes
127

127

127

2
Process coupling
• Connection to controller

• S7-1200
• S7-1500
• Zones
- Number of zones per
project, max.
- Number of
transponders for zones
per project, max.
• Effective range
- Number of effective
ranges per project,
max.
- Number of
transponders for
effective ranges per
project, max.
• Transponder
- Number of transponders per project, max.
- Adjustable distance
range
- Adjustable distance,
min.
- Adjustable distance,
max.

Yes
127

Yes
256

Yes
256

Yes
256

Yes
256

Yes

Yes

Yes

Yes

2m

2m

2m

2m

8m

8m

8m

8m

I/O
I/O devices
• Multi Media Card

Barcode reader
Yes

Barcode reader
Yes

Barcode reader
Yes

Barcode reader
Yes

Barcode reader
Yes

Mechanics/material
Type of housing (front)

Plastic

Plastic

Plastic

Plastic

Plastic

Dia 290 mm / D 103 mm Dia 290 mm / D 103 mm

Dia 290 mm / D 103 mm

Dia 290 mm / D 103 mm

Dia 290 mm / D 103 mm

2.2 kg

2.2 kg

2.2 kg

2.2 kg

Dimensions
Housing diameter/depth
(mm)
Weight
Weight

2/66

Siemens ST 80 / ST PC · 2013

2.2 kg

© Siemens AG 2013

Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277(F) IWLAN

■ Ordering data
SIMATIC Mobile Panel 277
IWLAN V2 (RoW version 1))
• Communication via WLAN
(PROFINET)
• Communication via WLAN
(PROFINET)
with integrated handwheel,
key-operated switch and
two illuminated pushbuttons
SIMATIC Mobile Panel 277F
IWLAN V2 PROFIsafe
(RoW version 1))
• Communication via WLAN
(PROFINET)
with acknowledgement button and
emergency stop button
• Communication via WLAN
(PROFINET)
with acknowledgement button and
emergency stop button with integrated handwheel, key-operated
switch, and two illuminated pushbuttons
• RFID tag version: Communication
via WLAN (PROFINET) with acknowledgement button and emergency stop button with integrated
handwheel, key-operated switch,
and two illuminated pushbuttons
SIMATIC Mobile Panel 277
IWLAN V2 (USA version)
• Communication via WLAN
(PROFINET)
• Communication via WLAN
(PROFINET)
with integrated handwheel,
key-operated switch and
two illuminated pushbuttons
SIMATIC Mobile Panel 277F
IWLAN V2 PROFIsafe
(USA version)
• with acknowledgement button and
emergency stop button
• with acknowledgement button and
emergency stop button with integrated handwheel, key-operated
switch, and two illuminated pushbuttons
• with acknowledgement button and
emergency stop button with integrated handwheel, key-operated
switch, and two illuminated pushbuttons (tag version)

Order No.

Order No.
See HMI accessories,
from page 2/99

Accessories
6AV6645-0DD01-0AX1
6AV6645-0DE01-0AX1

Note:
Please order the table-top power
supply or charging station as well.
Required for charging the battery.
Documentation

6AV6645-0EB01-0AX1

SIMATIC HMI Manual Collection
6AV6645-0EC01-0AX1

2

You can find the manuals for the
Mobile Panels on the Internet at:
http://support.automation.siemens.com/WW/view/en/11599011/
133300
6AV6691-1SA01-0AX0

Electronic documentation on DVD,
5 languages (English, German,
French, Italian and Spanish);
contains: all currently available user
manuals, device manuals and communication manuals for
SIMATIC HMI

6AV6645-0EF01-0AX1

6AV6645-0FD01-0AX1
6AV6645-0FE01-0AX1

6AV6645-0GB01-0AX1
6AV6645-0GC01-0AX1

6AV6645-0GF01-0AX1

Starter kit
SIMATIC Mobile Panel 277(F)
IWLAN (RoW version1))
for
• Mobile Panel 277 IWLAN V2
• Mobile Panel 277F IWLAN V2

6AV6651-5GA01-0AA1
6AV6651-5HA01-0AA1
1)

RoW version: "Rest of World" version:
Version for worldwide sales except in the U.S.

2)

Already prepared for Rapid Roaming (iPCF-MC). iPCF-MC is already
included from SCALANCE FW version V4.3.37 and higher.

For national approvals see:
http://www.siemens.com/wireless-approvals
The Function Manuals "Fail-Safe Operation of the Mobile Panel
277F IWLAN V1" are available for downloading in English,
German, and Japanese.
http://support.automation.siemens.com/WW/view/en/31255853

Siemens ST 80 / ST PC · 2013

2/67

© Siemens AG 2013

Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277(F) IWLAN

■ Dimensional drawings

■ More information

All dimensions in mm. For installation cutout, see technical
specifications.

Additional information is available in the Internet under:
http://www.siemens.com/simatic-mobile-panels
Note
Do you need a specific modification or addition to the products
described here? Then take a look under "Customer-specific
products". There, you will find information on ordering additional
and standard industry products as well as possibilities for
customer-specific modifications and adjustments.

8°

ø 290 mm

Mobile Panel 277(F) IWLAN, front and side view

2/68

Siemens ST 80 / ST PC · 2013

103 mm
129 mm

G_ST80_XX_00299

155

117

9

2

© Siemens AG 2013

Operator panels
System components
System components for Mobile Panels

■ Overview
System components for Mobile Panels are perfectly matched
to the SIMATIC HMI Mobile Panels. Charging stations,
transponders, and diverse connection boxes are available for
various applications.
Accessories for SIMATIC HMI Mobile Panels can be found under
"SIMATIC HMI accessories".
Only the latest SIMATIC HMI accessories are listed in this
section; the full range of SIMATIC HMI accessories is available
in the Mall and in our other online media.

Siemens ST 80 / ST PC · 2013

2/69

2

© Siemens AG 2013

Operator panels
System components
Terminal boxes

■ Overview

2

■ Technical specifications
6AV6671-5AE00-0AX0

6AV6671-5AE10-0AX0

6AV6671-5AE01-0AX0

6AV6671-5AE11-0AX0

DP connection box for
Mobile Panel 177/277
(MPI/PROFIBUS) Basic

DP connection box for
Mobile Panel 177/277
(MPI/PROFIBUS) Plus

PN connection box for
Mobile Panel 177/277
(PROFINET) Basic

PN connection box for
Mobile Panel 177/277
(PROFINET) Plus

with emergency stop circuit
interruption
No

without emergency stop
circuit interruption
Yes

with emergency stop circuit
interruption
No

without emergency stop
circuit interruption
Yes

Yes

No

Yes

No

No
Yes

Yes
Yes

No
Yes

Yes
Yes

Supply voltage
Type of actuation
• AC
• DC

DC
No
Yes

DC
No
Yes

DC
No
Yes

DC
No
Yes

Rated voltage

24 V

24 V

24 V

24 V

permissible range
• Supply voltage range
• Supply voltage range

+20.4 V to +28.8 V DC
20.4 V
28.8 V

+20.4 V to +28.8 V DC
20.4 V
28.8 V

+20.4 V to +28.8 V DC
20.4 V
28.8 V

+20.4 V to +28.8 V DC
20.4 V
28.8 V

Supply voltage

24 V DC

24 V DC

24 V DC

24 V DC

Input current
Rated current

0.4 A

0.5 A

0.4 A

0.5 A

Power
Power

10 W

12 W

10 W

12 W

1 x RS232, 1 x RS422,
1 x RS485 (max. 12 Mbit/s)

1 x RS232, 1 x RS422,
1 x RS485 (max. 12 Mbit/s)

2 x Ethernet (RJ45)

2 x Ethernet (RJ45)

Number of 20 mA interfaces
(TTY)

0

0

Number of RS 232 interfaces

1

1

Number of RS 422 interfaces

1

1
2 x Ethernet (RJ45)
6

2 x Ethernet (RJ45)
6

Control elements
Expansions for operator control
of the process
• Hot swapping
- without emergency stop
circuit interruption
- with emergency stop circuit
interruption
- Monitoring the STOP button
- Location identifier

Interfaces
Interfaces

Industrial Ethernet
• Industrial Ethernet interface
• Industrial Ethernet status LED

2/70

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
System components
Terminal boxes

■ Technical specifications (continued)
6AV6671-5AE00-0AX0

6AV6671-5AE10-0AX0

6AV6671-5AE01-0AX0

6AV6671-5AE11-0AX0

DP connection box for
Mobile Panel 177/277
(MPI/PROFIBUS) Basic

DP connection box for
Mobile Panel 177/277
(MPI/PROFIBUS) Plus

PN connection box for
Mobile Panel 177/277
(PROFINET) Basic

PN connection box for
Mobile Panel 177/277
(PROFINET) Plus

IP65

IP65

IP65

IP65

IP20 housing

No

No

No

No

IP54 housing

No

No

No

No

IP65 enclosure

Yes

Yes

Yes

Yes

NEMA 4

No

No

No

No

NEMA 4X

No

No

No

No

NEMA 12

No

No

No

No

Standards, approvals,
certificates
Certifications

CE, cULus, C-TICK

CE, cULus, C-TICK

CE, cULus, C-TICK

CE, cULus, C-TICK

CE

Yes

Yes

Yes

Yes

CSA

No

No

No

No

UL

No

No

No

No

FM Class I Div. 2

No

No

No

No

GL

No

No

No

No

ABS

No

No

No

No

BV

No

No

No

No

DNV

No

No

No

No

LRS

No

No

No

No

PRS

No

No

No

No

Gost-R

No

No

No

No

Use in hazardous areas
• EX zone 2
• EX zone 22

No
No

No
No

No
No

No
No

0 °C to +50 °C

0 °C to +50 °C

0 °C to +50 °C

0 °C to +50 °C

0 °C

0 °C

0 °C

0 °C

50 °C

50 °C

50 °C

50 °C

-20 °C

-20 °C

-20 °C

-20 °C

70 °C

70 °C

70 °C

70 °C

-20 °C to +70 °C

-20 °C to +70 °C

-20 °C to +70 °C

-20 °C to +70 °C

85 %

85 %

85 %

85 %

Yes

Yes

Yes

Yes

160 x 120 x 70

160 x 120 x 70

230 x 120 x 80

230 x 120 x 80

160
120
70

160
120
70

230
120
80

230
120
80

Weight
Weight

0.35 kg

0.4 kg

0.45 kg

0.5 kg

other
free hotline

Yes

Yes

Yes

Yes

Warranty period

1a

1a

1a

1a

Degree and class of
protection
Enclosure according to
EN 60529

Ambient conditions
Operating temperature
• Operation
(vertical installation)
- in vertical mounting
position/ minimum
- in vertical mounting
position/ maximum
Storage/transport temperature
• Ambient temperature
during storage, minimum
• Ambient temperature
during storage, maximal
• Transport, storage
Relative humidity
• max. relative humidity
Functionality under WinCC
(TIA Portal)
Applications/options
• Connection point
identification
Dimensions
External dimensions
(W x H x D) in mm
• Width
• Height
• Depth

Siemens ST 80 / ST PC · 2013

2

2/71

© Siemens AG 2013

Operator panels
System components
Terminal boxes

■ Dimensional drawings
All dimensions in mm. For installation cutout, see technical
specifications.

6AV6671-5AE00-0AX0
6AV6671-5AE10-0AX0

6AV6671-5AE01-0AX0
6AV6671-5AE11-0AX0

62.7

140

G_ST80_XX_00045

11 0
120
142 ± 2

160
150

DP connection box for SIMATIC Mobile Panel

230
55

110
120
142 ± 2

220

4.5

PN connection box for SIMATIC Mobile Panel

2/72

Siemens ST 80 / ST PC · 2013

G_ST80_XX_00273

76

210

10

2

PN connection box
for Mobile Panels 177/277
(PROFINET)
• Basic
• Plus

Order No.

43

DP connection box
for Mobile Panels 177/277
(MPI/PROFIBUS)
• Basic
• Plus

10

■ Ordering data

© Siemens AG 2013

Operator panels
System components
SIPLUS connection boxes

■ Overview

■ Ordering data

Order No.

SIPLUS connection box DP Plus
for Mobile Panels 177/277
(MPI/PROFIBUS)

6AG1671-5AE10-4AX0

2

Note:
SIPLUS extreme products are based on Siemens Industry
standard products. The contents listed here were taken from the
respective standard products. SIPLUS extreme-specific information was added.
SIPLUS connection box DP Plus
Order number

6AG1 671-5AE10-4AX0

Order number based on

6AV6 671-5AE10-0AX0

Ambient temperature range

0 ... +50 °C

Conformal coating

Coating of the printed circuit boards
and the electronic components

Technical data

The technical data of the standard
product applies except for the
ambient conditions.

Ambient conditions
Relative humidity

100%, condensation/frost
permissible. No commissioning
if condensation present.

Air pressure
(depending on the highest positive
temperature range specified)

1080 ... 795 hPa (-1000 ... +2000m)
see ambient temperature range
795 ... 658 hPa (+2000 ... +3500m)
derating 10 K
658 … 540 hPa (+3500 … +5000m)
derating 20 K

Siemens ST 80 / ST PC · 2013

2/73

© Siemens AG 2013

Operator panels
System components
Charging station

■ Overview

■ Ordering data

Order No.

Charging station for
Mobile Panels

6AV6671-5CE00-0AX1

■ Dimensional drawings
All dimensions in mm. For installation cutout, see technical
specifications.

85

2

160

24 V

permissible range
• Supply voltage range
• Supply voltage range

+19.2 V to +28.8 V DC
19.2 V
28.8 V

Supply voltage

24 V DC

Input current
Rated current

3.2 A

Power
Power

77 W

Degree and class of protection
Enclosure according to EN 60529

IP65

IP65 enclosure

Yes

Standards, approvals, certificates
Certifications

CE, cULus, C-TICK

CE

Yes

Ambient conditions
Operating temperature
• Operation (vertical installation)
- in vertical mounting position/
minimum
- in vertical mounting position/
maximum

0 °C to +40 °C
0 °C

208

Storage/transport temperature
• Ambient temperature during storage,
minimum
• Ambient temperature during storage,
maximal
• Transport, storage
Relative humidity
• max. relative humidity
Dimensions
External dimensions
(W x H x D) in mm
• Width
• Height
• Depth
Weight
Weight

2/74

40 °C

-20 °C
60 °C
-20 °C to +60 °C
85 %
208 x 333 x 75
208
333
75
1.1 kg

Siemens ST 80 / ST PC · 2013

72

G_ST80_XX_00297

Rated voltage

198

DC
Yes

61

6AV6671-5CE00-0AX1
Supply voltage
Type of actuation
• DC

343

■ Technical specifications

© Siemens AG 2013

Operator panels
System components
Transponder

■ Overview

■ Ordering data

Order No.

Transponder for
Mobile Panels 277

6AV6671-5CM00-0AX1

■ Dimensional drawings
All dimensions in mm. For installation cutout, see technical
specifications.

45

90

2

38.5

■ Technical specifications
6AV6671-5CM00-0AX1
Degree and class of protection
Enclosure according to EN 60529

IP65

IP65 enclosure

Yes

Enclosure according to NEMA

NEMA 4x, NEMA 12

NEMA 4X

Yes

NEMA 12

Yes

Standards, approvals, certificates
Certifications

CE, cULus, C-TICK, NEMA 4x,
NEMA 12

CE

Yes

Ambient conditions
Operating temperature
• Operation (vertical installation)
- in vertical mounting position/
minimum
- in vertical mounting position/
maximum

0 °C to +50 °C
0 °C

Storage/transport temperature
• Ambient temperature during storage,
minimum
• Ambient temperature during storage,
maximal
• Transport, storage
Relative humidity
• max. relative humidity
Dimensions
External dimensions
(W x H x D) in mm
• Width
• Height
• Depth
Weight
Weight

172

G_ST80_XX_00298

162

50 °C

-20 °C
60 °C
-20 °C to +60 °C
85 %
172 x 90 x 38.5
172
90
38.5
0.3 kg

Siemens ST 80 / ST PC · 2013

2/75

© Siemens AG 2013

Operator panels
System interfaces with WinCC (TIA Portal)
System interfaces with WinCC (TIA Portal)

■ Overview

2

The SIMATIC Touch Panel (TP), Operator Panel (OP),
Basic Panel, Comfort Panel, Mobile Panel, multifunctional
platforms (MP)1) offer HMI functionality for the control systems:
• SIMATIC S7
• Non-Siemens controllers:
- Allen Bradley
- Mitsubishi
- Modicon
- Omron
For more detailed information, refer to the WinCC (TIA Portal)
user manual, the "Windows-based systems communication"
manual, or the WinCC (TIA Portal) online help.
OPC communication and HTTP communication are offered for all
Panels with an integrated Ethernet interface. Both OPC and
HTTP communication can be used in parallel with the process
links to SIMATIC S7 or non-Siemens PLCs.
1)

Note:
Interface options for HMI devices: See the individual device
descriptions.
OPC communication
OPC Data Access is an open standard for exchanging both local
and remote variables between various applications via Industrial
Ethernet. The original version of OPC is based on Microsoft
COM/DCOM and, therefore, requires a Microsoft Windowsbased PC operating system (not Windows CE) on both clients
and servers. As OPC XML, communication is based on the
Internet standard SOAP/XML and is, therefore, suitable for
embedded systems with Windows CE.
HTTP communication for variable exchange between
SIMATIC HMI systems
Communication based on HTTP message frames enables
variables to be exchanged between SIMATIC HMI systems.

For the sake of simplicity, SIMATIC Panel is always used in the text below.
This is not restrictive, as the information is valid for all systems referred to
above. If there are constraints, direct reference is made to them in the text.

Communication standard

SIMATIC HMI

Version

Comfort Panel

TP 177B DP/PN
OP 177B DP/PN
Mobile Panel 177 PN
MP 177

TP 277
OP 277
Mobile Panel 277

MP 277
MP 377

WinCC Runtime
Advanced

OPC Data Access V2.05a + OPC UA Data Access V1.01 + OPC Data Access XML V1.00
OPC DA Client
(COM/DCOM)

–

–

–

–

•

OPC DA server
(COM/DCOM)

–

–

–

–

•

OPC UA client

•

–

–

–

•

OPC XML DA client
(SOAP/XML)

–

–

–

–

• 1)

OPC XML DA server
(SOAP/XML)

•

–

–

•

–

HTTP communication for variable exchange between SIMATIC HMI systems
HTTP client

•

•

•

•

•

HTTP server

•

•

•

•

•

• System interface possible
– System interface not possible
1)

Only through DCOM/XML gateway in scope of delivery of
WinCC Advanced for access to OPC XML server of the SIMATIC Panel

2/76

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
System interfaces with WinCC (TIA Portal)
SIMATIC S7

■ Overview
The following types of interface are differentiated in respect of
the link between the SIMATIC Panels and SIMATIC S7
controllers:
• PROFINET interface:
Coupling of SIMATIC Panel to SIMATIC S7 controllers via
Industrial Ethernet TCP/IP using the integrated PROFINET
interface of the CPU or, alternatively, a PROFINET interface
module.
• MPI/PROFIBUS interface:
Coupling of SIMATIC Panel to SIMATIC S7 controllers via MPI/
PROFIBUS using the integrated MPI/PROFIBUS interface of
the CPU for S7-300, S7-400 or the integrated PPI interface of
the CPU in the case of S7-200 or, alternatively, a PROFIBUS
interface module in the case of S7-1200, S7-300 and S7-400.
• PPI interface:
Coupling of SIMATIC Panel to SIMATIC S7-200 via PPI network
using the integrated PPI interface of the CPU

PPI interface

The maximum possible number of S7 connections of one CPU is
determined by its performance capacity (see Catalog ST 70);
from the point of view of SIMATIC Panel, the following restrictions
apply:
• OP 73: max. 2 connections
• OP 77A, TP 177A, Basic Panel, OP 77B, TP177B, OP 177B,
Mobile Panel 177: max. 4 connections
• Comfort Panel, TP 277, OP 277; Mobile Panel 277, MP 177,
MP 277, MP 377: max. 6 connections
• PC with WinCC Runtime Advanced: max. 8 connections

The original format of a master/master link has been joined by a
master/slave link, which has enabled integration of the S7-200
(except CPU 212).1)

The PPI interface is a point-to-point connection between a
SIMATIC Panel (PPI master) or alternatively a PG (PPI master)
and an S7-200 (PPI slave).
The corresponding multipoint-enabled communication interfaces of SIMATIC Panels and SIMATIC S7 are used.
The following are possible:
• Interface between one or a number of SIMATIC Panels (MPI
master) and one or a number of S7-1200/300/400s or WinAC
(MPI master).(possible network topology: MPI/PROFIBUS or
Industrial Ethernet, TCP/IP)
• Interface between one or a number of SIMATIC Panels
(MPI master) and one or a number of S7-200s (MPI slave)1)
(possible network topology: PPI, MPI/PROFIBUS)
Unlike PPI connections, MPI connections are static connections
that are set up during booting and then monitored.

In principle this type of information exchange between SIMATIC
Panels and SIMATIC S7 is independent of the network used, PPI,
MPI/PROFIBUS or Industrial Ethernet: SIMATIC Panels are
S7 clients and SIMATIC S7 CPUs are S7 servers.
1)

With regard to restricted baud transmission rates for S7-200,
see Catalog ST 70.

Siemens ST 80 / ST PC · 2013

2/77

2

© Siemens AG 2013

Operator panels
System interfaces with WinCC (TIA Portal)
SIMATIC S7

■ Overview (continued)

2

Controller

SIMATIC HMI

Target hardware (PROTOCOL)
(physics)

OP 73
OP 77A
TP 177A

Basic Panel

Comfort Panel

OP 77B
TP 177B DP
OP 177B DP
TP 177B DP/PN
OP 177B DP/PN
Mobile Panel 177 DP1)
Mobile Panel 177 PN 1)

TP 277
OP 277
Mobile Panel 277 1)
MP 177
MP 277
MP 377

WinCC Runtime
Advanced

via Ethernet (TCP/IP)
to max. 4 x S7-1200

–

• 5)

•

• 5)

•

•

via MPI or PROFIBUS network
to max. 4 x S7-1200 with
PROFIBUS module (DP-Master)
CM 1243-5

• 3) 4)

• 6)

•

•5)

•

• 7)

via Ethernet (TCP/IP)
to max. 4 x S7-300, -400,
WinAC

–

• 5)

•

• 5)

•

•

via MPI or PROFIBUS network
to up to 4 x S7-300, S7-400,
WinAC

• 3) 4)

• 6)

•

• 6)

•

• 7)

via Ethernet (TCP/IP)
(MPI protocol)
to max. 4 x S7-200

–

• 5)

•

• 5)

•

•

via MPI or PROFIBUS network
(MPI protocol)
to up to 4 x S7-200

• 3) 4)

• 6)

• 8)

• 6) 8)

• 8)

• 7) 8)

via PPI network
(MPI protocol)
to up to 4 x S7-200

• 3) 4)

• 6)

–

• 9)

–

–

via PPI network
(PPI protocol)
to max. 1 x S7-200

–

–

• 10)

• 10)

• 10)

• 7)10)

SIMATIC S7-1200 2)

SIMATIC S7-300, -400, Win AC 2)

SIMATIC S7-200 2)

• System interface possible
– System interface not possible
1)

Mobile Panel connection via special connecting cable and junction box
(see Mobile Panel), see Manual for cable layout.

2)

Controllers can be combined as desired

3)

OP 73 can only be interfaced with max. 2 x SIMATIC S7 (MPI);
network operation (parallel PG, etc.) possible

4)
5)

Max. transmission rate 1.5 Mbit/s
Only Basic Panel PN, TP 177B DP/PN, OP 177B DP/PN,
Mobile Panel 177 PN

6)

Not Basic Panel PN, Mobile Panel 177 PN

7)

Connection via integrated MPI/PROFIBUS interface; use the CP 5611 A2
with a standard PC

8)

Only on passive S7-200; OP 77B also on active S7-200
Only OP 77B

9)
10)

Can be interfaced via PPI to max. 1 x S7-200 (PPI);
network operation (parallel PG, etc) is possible

2/78

Siemens ST 80 / ST PC · 2013

Note:
Detailed information regarding cable layout can be found in the
online help for WinCC.

© Siemens AG 2013

Operator panels
System interfaces with WinCC (TIA Portal)
Controllers from other manufacturers

■ Overview
The SIMATIC Touch Panel (TP), Operator Panel (OP), Basic
Panel, Comfort Panel, Mobile Panel, multifunctional platforms
(MP) and the SIMATIC HMI software package for PC WinCC
Runtime Advanced support the following protocols for the linking
of control systems from other manufacturers:
• Allen Bradley
- Ethernet IP protocol
- DF1 protocol

• Mitsubishi
- MC TCP/IP protocol
- FX protocol
• Modicon
- Modbus TCP/IP protocol
- Modbus RTU protocol
• Omron
- Link/Multi-Link protocol

2

The following table contains more detailed information.
Controller

SIMATIC HMI

Target hardware (PROTOCOL)
(physics)

OP 77A
TP 177A

Basic Panel

Comfort Panel

OP 77B
TP 177B DP
OP 177B DP
TP 177B DP/PN
OP 177B DP/PN
Mobile Panel 177 DP1)
Mobile Panel 177 PN 1)

TP 277
OP 277
Mobile Panel 277 1)
MP 177
MP 277
MP 377

WinCC Runtime
Advanced

–

• 3)

•

• 3)

•

•

• 4)

• 4) 5)

• 4)

• 4) 5)

• 4)

• 6)

• 4)

• 4) 5)

• 4)

• 4) 5)

• 4)

• 7)

• 4)

• 4) 5)

• 4)

• 4) 5)

• 4)

• 7) 8)

•

• 5)

•

• 5)

•

–

• 4)

• 4) 5)

• 4)

• 4) 5)

• 4)

• 7) 8)

Allen Bradley (Ethernet IP)
via Ethernet TCP/IP network
to max. 4 x controllers 2)
• ControlLogix 1756-L6x, -L6xS
with Ethernet module
1756-ENBT
• Guard Logix System
• CompactLogix 1769-L2xE,
-L3xE
• CompactLogix 1769-L4x with
ETHERNET module
1768-ENBT
• SLC 5/05
• MicroLogix 1100, 1400
Allen Bradley (DF1)
to max. 1 x controller
• SLC 5/03, /04, /05
• MicroLogix (RS 232)
to max. 1 x controller
• PLC5/11, /20, /30, /40, /60, /80
(RS 232)
via KF2 gateway and DH+ network to max. 4 x controllers 2)
• SLC 5/04
• PLC5/11, /20, /30, /40, /60, /80
(RS 232)
via KF2 gateway and DH+ network to max. 4 x controllers 2)
• SLC 5/04
• PLC5/11, /20, /30, /40, /60, /80
(RS 422)
via KF3 gateway and DH485
network to max.
4 x controllers 2)
• SLC 500
• MicroLogix (RS 232)

• System interface possible
– System interface not possible
1)

Mobile Panel connection via special connecting cable and junction box
(see Mobile Panel), see Manual for cable layout.

2)

The following listed controllers can be combined as required

3)

Only Basic Panel PN, TP 177B DP/PN, OP 177B DP/PN,
Mobile Panel 177 PN

4)

For Basic Panel, Touch Panel, Operator Panel, Comfort Panel, Multi Panel,
the RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is required

5)

Not Basic Panel PN, Mobile Panel 177 PN
Connection via Allen Bradley PC cable 1747 CP3

6)
7)
8)

Note:
For detailed information on cable assignment, refer to Online
Help of WinCC; see also FAQs:
http://support.automation.siemens.com/WW/view/en/29034071

Connection via Allen Bradley PC cable 1784 CP10
For connection to KF2/KF3 gateway, a gender-changer
(25-pin socket/25-pin socket) is required on the gateway side

Siemens ST 80 / ST PC · 2013

2/79

© Siemens AG 2013

Operator panels
System interfaces with WinCC (TIA Portal)
Controllers from other manufacturers

■ Overview (continued)

2

Controller

SIMATIC HMI

Target hardware (PROTOCOL)
(physics)

OP 77A
TP 177A

Basic Panel

Comfort Panel

OP 77B
TP 177B DP
OP 177B DP
TP 177B DP/PN
OP 177B DP/PN
Mobile Panel 177 DP1)
Mobile Panel 177 PN 1)

TP 277
OP 277
Mobile Panel 277 1)
MP 177
MP 277
MP 377

WinCC Runtime
Advanced

–

• 3)

•

• 3)

•

•

•

• 4)

•

• 4)

•

• 5)

Mitsubishi (MC TCP/IP)
via Ethernet IP network
to max. 4 x controllers 2)
• FX series FX3G, FX3U, FX3UC
with Ethernet module FX3U
ENET,
• Series Q with Ethernet module
QJ71E71-100
• iQ series/QnUD QnUDEH
Mitsubishi FX (serial)
to max. 1 x controller
FX series FX1N, FX2N (RS 232)

• System interface possible
– System interface not possible
1)

Mobile Panel connection via special connecting cable and junction box
(see Mobile Panel), see Manual for cable layout.

2)

The following listed controllers can be combined as required

3)

Only Basic Panel PN, TP 177B DP/PN, OP 177B DP/PN,
Mobile Panel 177 PN

4)

Not Basic Panel PN, Mobile Panel 177 PN

5)

Connection using a Mitsubishi PC cable SC-09 with integrated level
converter RS 232/RS 422

2/80

Siemens ST 80 / ST PC · 2013

Note:
For detailed information on cable assignment, refer to Online
Help of WinCC; see also FAQs:
http://support.automation.siemens.com/WW/view/en/29034071

© Siemens AG 2013

Operator panels
System interfaces with WinCC (TIA Portal)
Controllers from other manufacturers

■ Overview (continued)
Controller

SIMATIC HMI

Target hardware (PROTOCOL)
(physics)

OP 77A
TP 177A

Basic Panel

Comfort Panel

OP 77B
TP 177B DP
OP 177B DP
TP 177B DP/PN
OP 177B DP/PN
Mobile Panel 177 DP1)
Mobile Panel 177 PN 1)

TP 277
OP 277
Mobile Panel 277 1)
MP 177
MP 277
MP 377

WinCC Runtime
Advanced

3)

•

•

2

Modicon (MODBUS TCP/IP)
Via MODBUS TCP/IP network to
max. 4 x controllers 2)
• Concept Quantum,
Unity Quantum
• Momentum
• Premium (TSX57)
• TSX Micro (TSX37)
• Modicon M340 20x0
(except 2010)
Via TCP/IP Modbus Plus
Bridge 174 CEV 200 40 and
MODBUS PLUS network to
max. 4 x controllers 2)
• Concept Quantum,
Unity Quantum
• Momentum
• Compact

–

•

3)

•

•

–

• 3)

•

• 3)

•

•

• 4)

• 4) 5)

• 4)

• 4) 5)

• 4)

•

• 4)

• 4) 5)

• 4)

• 4) 5)

• 4)

•

Modicon (MODBUS RTU)
to max. 1 x controller
• Concept Quantum
• Momentum
• Compact
(RS 232)
Via bridge BM85-000 or PLC
with bridge functionality and
MODBUS PLUS network to
max. 4 x controllers 2)
• Concept Quantum
• Compact (RS 232)

• System interface possible
– System interface not possible
1)

Mobile Panel connection via special connecting cable and junction box
(see Mobile Panel), see Manual for cable layout.

2)

The following listed controllers can be combined as required

3)

Only Basic Panel PN, TP 177B DP/PN, OP 177B DP/PN,
Mobile Panel 177 PN

4)

For Basic Panel, Touch Panel, Operator Panel, Comfort Panel, Multi Panel,
the RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is required

5)

Not Basic Panel PN, Mobile Panel 177 PN

Note:
For detailed information on cable assignment, refer to Online
Help of WinCC; see also FAQs:
http://support.automation.siemens.com/WW/view/en/29034071

Siemens ST 80 / ST PC · 2013

2/81

© Siemens AG 2013

Operator panels
System interfaces with WinCC (TIA Portal)
Controllers from other manufacturers

■ Overview (continued)

2

Controller

SIMATIC HMI

Target hardware (PROTOCOL)
(physics)

OP 77A
TP 177A

Basic Panel

Comfort Panel

OP 77B
TP 177B DP
OP 177B DP
TP 177B DP/PN
OP 177B DP/PN
Mobile Panel 177 DP1)
Mobile Panel 177 PN 1)

TP 277
OP 277
Mobile Panel 277 1)
MP 177
MP 277
MP 377

WinCC Runtime
Advanced

–

–

• 3)

• 3) 4)

• 3)

•

–

–

• 3)

• 3) 4)

• 3)

•

•

• 4)

•

• 4)

• 4)

–

–

–

–

• 4)

• 4)

–

Omron (Link/MultiLink)
to max. 1 x controller
• CP1L, CP1H, CP1E
• CJ1M, CJ1H, CJ1G
• CJ2H
• CS1G, CS1H, CS1D
• CP2MC (RS 232)
via converter NT-AL001 and
RS 422 network to
max.4 x controllers 2)
• CP1L, CP1H, CP1E
• CJ1M, CJ1H, CJ1G
• CJ2H
• CS1G, CS1H, CS1D
• CP2MC (RS 232)
via RS 422 network to
max. 4 x controllers 2)
• CP1L, CP1H, CP1E
• CJ1M, CJ1H, CJ1G
(RS 422)
via RS422 network to
max. 4 x controllers 2)
• CJ2H
• CS1G, CS1H, CS1D
• CP2MC (RS 422)

• System interface possible
– System interface not possible
1)

Mobile Panel connection via special connecting cable and junction box
(see Mobile Panel), see Manual for cable layout.

2)

The controllers listed below can be combined in any way required;
connection via RS 422 interface of the controller or via RS 422 module
For Basic Panel, Touch Panel, Operator Panel, Comfort Panel, Multi Panel,
the RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is required

3)
4)

Not Basic Panel PN, Mobile Panel 177 PN

2/82

Siemens ST 80 / ST PC · 2013

Note:
For detailed information on cable assignment, refer to Online
Help of WinCC; see also FAQs:
http://support.automation.siemens.com/WW/view/en/29034071

© Siemens AG 2013

Operator panels
System interfaces with WinCC flexible
System interfaces with WinCC flexible

■ Overview
SIMATIC Basic Panel, Touch Panels (TP), Operator Panels (OP),
Mobile Panel, Multifunctional Platforms (MP)1) and the SIMATIC
HMI software package for PC WinCC flexible Runtime support
HMI functionality in conjunction with:
• SIMATIC S7
• SIMATIC S5
• SIMATIC 505
• SIMOTION
• SINUMERIK 2)
• Non-Siemens controllers:
- Allen Bradley - DF1, DH485 and Ethernet IP protocols
- GE Fanuc - SNP/SNPX protocol
- LG GLOFA GM - dedicated protocol
- Mitsubishi - FX and MP 4 protocols
- Modicon - Modbus RTU and TCP/IP protocols
- Omron I - Link/MultiLink protocol
- Telemecanique - UNI-TELWAY protocol

Extended functionality with WinCC flexible

For more detailed information, refer to the WinCC flexible user
manual, the "Windows-based systems communication" manual,
and the WinCC flexible online help.

HTTP communication for the variable exchange between
SIMATIC HMI systems
(only TP 177B DP/PN, OP 177B DP/PN, Mobile Panel 177 PN,
TP 277, OP 277, Mobile Panel 277, Mobile Panel 277 IWLAN,
MP 277, MP 377, WinCC flexible Runtime)

1)

2)

For the sake of simplicity, SIMATIC TP/OP/MP is always used in the text
below. This is not restrictive, as the information is valid for all systems
referred to above. If there are constraints, direct reference is made to them
in the text.
Required under WinCC flexible: "SINUMERIK HMI copy license
WinCC flexible CE" and "SINUMERIK HMI copy license OA".
For configuring, a "SINUMERIK HMI engineering package WinCC flexible"
is also necessary.

WinCC flexible supports OPC communication for Multi Panel
and WinCC flexible Runtime and HTTP communication for all
panels with integrated Ethernet interface. Both OPC and HTTP
communication can be used in parallel with the process links to
SIMATIC S7/S5/505 or non-Siemens PLCs.
OPC Data Access
(MP 277, MP 377, WinCC flexible Runtime only)
OPC Data Access is an open standard for exchanging both local
and remote variables between various applications via Industrial
Ethernet. The original version of OPC is based on Microsoft
COM/DCOM and, therefore, requires a Microsoft Windowsbased PC operating system (not Windows CE) on both clients
and servers. As OPC XML, communication is based on the
Internet standard SOAP/XML and is, therefore, suitable for
embedded systems with Windows CE.
Options that are required: WinCC flexible/OPC server

Communication based on HTTP message frames enables
variables to be exchanged between SIMATIC HMI systems.
Options that are required: WinCC flexible/Sm@rt Access

Note
Interface options for HMI devices: See the individual device
descriptions.
Communication standard

SIMATIC HMI

Version

TP 177B DP/PN

TP 277

Mobile Panel 277

OP 177B DP/PN
Mobile Panel 177 PN

OP 277

Mobile Panel 277
IWLAN

6)

WinCC flexible
Runtime

Connection via

MP 277
MP 377

MP 177
OPC Data Access V2.05a + OPC Data Access XML V1.00
OPC client
(COM/DCOM)

–

–

–

•

Industrial Ethernet
(see Catalog IK PI)

OPC server
(COM/DCOM)

–

–

–

•1)

Industrial Ethernet
(see Catalog IK PI)

OPC XML client
(SOAP/XML)

–

–

–

•2)

Industrial Ethernet
(see Catalog IK PI)

OPC XML server
(SOAP/XML)

–

–

•3)

–

Industrial Ethernet
(see Catalog IK PI)

HTTP communication for variable exchange between SIMATIC HMI systems
HTTP client

•4)

•4)

•4)

•5)

Industrial Ethernet
(see Catalog IK PI)

HTTP server

•4)

•4)

•4)

•5)

Industrial Ethernet
(see Catalog IK PI)

• System interface possible
– System interface not possible
1)

Option WinCC flexible/OPC Server for WinCC flexible Runtime required

4)

Option WinCC flexible/Sm@rtAccess for SIMATIC Panel required

2)

Only with DCOM/XML gateway included in the scope of delivery of
WinCC flexible for access to MP 277, MP 377 and MP 370 OPC XML
servers
Option WinCC flexible/OPC Server for SIMATIC Multi Panel required

5)

Option WinCC flexible/Sm@rtAccess for WinCC flexible Runtime required
Depending on the terminal box used

3)

6)

Siemens ST 80 / ST PC · 2013

2/83

2

© Siemens AG 2013

Operator panels
System interfaces with WinCC flexible
SIMATIC S7

■ Overview

2

The following types of interface are supported in respect of the
link between SIMATIC HMI Panels and SIMATIC WinCC flexible
Runtime with SIMATIC S7:
• PPI interface:
Interface between SIMATIC HMI Panels and SIMATIC S7-200
via PPI. Communication runs on the PPI protocol, a standard
FB as with SIMATIC S5 is not required.
• MPI interface:
Interface between SIMATIC HMI Panels and SIMATIC S7 via
the integrated PPI interface with S7-200 or MPI interface with
S7-300/-400 or alternatively via the MPI interface of a separate
interface module and the backplane bus to the SIMATIC S7CPU. Communication runs on the MPI protocol (PG/OP
communication), a standard FB as with SIMATIC S5 is not
required.
• PROFIBUS interface:
Interface between SIMATIC HMI Panels and SIMATIC S7 via
the integrated PROFIBUS interface on the CPU or alternatively
via the PROFIBUS interface on a separate interface module
and the backplane bus to the SIMATIC S7-CPU. Communication runs on the MPI protocol (PG/OP communication), a
standard FB as with SIMATIC S5 is not required.
• PROFINET interface:
Interface between SIMATIC HMI Panels and SIMATIC S7 via
the integrated PROFINET interface on the CPU or alternatively
via the Industrial Ethernet interface on a separate interface
module and the backplane bus to the SIMATIC S7-CPU.
Communication runs on the MPI protocol (PG/OP communication), a standard FB as with SIMATIC S5 is not required.
The maximum possible number of S7 connections of a CPU is
determined by its power (see Catalog ST 70); from the point of
view of SIMATIC HMI Panels the following restrictions apply:
• OP 73micro, TP 177micro: 1 connection
• OP 73: max. 2 connections
• OP 77A, TP 177A, Basic Panel, OP 77B, TP177B, OP 177B,
Mobile Panel 177: max. 4 connections
• TP 277, OP 277; Mobile Panel 277, MP 177, MP 277, MP 377:
max. 6 connections
• PC with WinCC flexible Runtime: max. 8 connections

2/84

Siemens ST 80 / ST PC · 2013

PPI interface
From the point of view of the concept, the PPI interface is a pointto-point connection between a SIMATIC HMI Panel (PPI master)
or alternatively a PG (PPI master), and an S7-200 (PPI slave).
MPI interface/PROFIBUS interface/
Industrial Ethernet interface
The multipoint-enabled communication interfaces of
SIMATIC HMI Panels and SIMATIC S7 are used.
Options are:
• Interface between one or a number of SIMATIC HMI Panels
(MPI master) and one or a number of S7-300/400s or WinAC
(MPI master)
(possible network topology: "MPI/PROFIBUS/Industrial
Ethernet")
• Interface between one or a number of SIMATIC HMI Panels
(MPI master) and one or a number of S7-200s (MPI slave) 1)
(possible network topology: "PPI/MPI/PROFIBUS")
Unlike PPI connections, MPI connections are static connections
that are set up during booting and then monitored.
The original format of a master/master link has in the meantime
been joined by a master/slave link, which has enabled
integration of the S7-200 (except CPU 212). 1)
In principle this type of information exchange between
SIMATIC HMI Panels and SIMATIC S7 is independent of the
network used, PPI, MPI, PROFIBUS or Industrial Ethernet:
SIMATIC HMI Panels are S7 clients and SIMATIC S7 CPUs are
S7 servers.
1)

Constraints with regard to baud rate for S7-200; see Catalog ST 70.

© Siemens AG 2013

Operator panels
System interfaces with WinCC flexible
SIMATIC S7

■ Overview (continued)
Controller

SIMATIC HMI

Target hardware (PROTOCOL)
(physics)

TD 100C

OP 73micro

TD 200
TD 200C

TP 177micro

OP 73

OP 77A

Connection via

TP 177A

TD 400C

2

SIMATIC S7 (PPI/MPI)
via PPI on S7-200 (PPI)

• 1)

–

–

–

MPI cable 5)

via MPI or PROFIBUS
(PG/OP communication)
with S7-200

–

• 2)

• 3)

• 4)

MPI cable 5)

via MPI or PROFIBUS
(PG/OP communication)
with S7-300, -400

–

–

• 3)

• 4)

MPI cable 5)

via PPI network (PPI)
with max. 1 x S7-200

• 1)

–

–

–

PPI network 6)
(see Catalog ST 70 and IK PI)

via PPI network
(PG/OP communication)
with max. 4 x S7-200

• 1)

• 2)

• 3)

• 4)

PPI network 6)
(see Catalog ST 70 and IK PI)

via MPI or PROFIBUS network
(PG/OP communication)
with max. 4 x S7-200

–

• 2)

• 3)

• 4)

MPI or PROFIBUS network 6)
(see Catalogs ST 70 and IK PI)

via MPI or PROFIBUS network
(PG/OP communication)
with max. 4 x S7-300, -400, WinAC

–

–

• 3)

• 4)

MPI or PROFIBUS network 6)
(see Catalogs ST 70 and IK PI)

via Industrial Ethernet (TCP/IP)
(PG/OP communication)
with max. 4 x S7-200, -300, -400,
WinAC

–

–

–

–

Industrial Ethernet
(see Catalog IK PI)

• System interface possible
– System interface not possible
1)

2)

TD series can only be interfaced with max. 1 x S7-200 via PPI (PPI/MPI);
network operation (parallel PG, etc.) possible; max. data transfer rate
187.5 kbit/s; cable included in scope of supply
OP 73micro, TP 177 micro can only be interfaced with max. 1 x S7-200
(MPI); network operation (parallel PG, etc.) possible; max. data transfer
rate 187.5 kbit/s

3)

OP 73 can only be interfaced with max. 2 x SIMATIC S7 (MPI); network
operation (parallel PG, etc.) possible; max. data transfer rate 1.5 Mbit/s

4)
5)

Max. transmission rate 1.5 Mbit/s
MPI cable 6ES7 901-0BF00-0AA0 (max. 187.5 Kbit/s) included in PG
scope of delivery

6)

Bus connector 6GK1 500-0EA02

Siemens ST 80 / ST PC · 2013

2/85

© Siemens AG 2013

Operator panels
System interfaces with WinCC flexible
SIMATIC S7

■ Overview (continued)
Controller

SIMATIC HMI

Target hardware (PROTOCOL)
(physics)

Basic Panels

2

OP 77B

TP 277

TP 177B DP
OP 177B DP

OP 277
Mobile Panel 277

TP 177B DP/PN
OP 177B DP/PN

Mobile Panel 277
IWLAN

Mobile Panel 177 DP
Mobile Panel 177 PN

MP 177
MP 277

WinCC flexible
Runtime

Connection via

MP 377

via PPI on S7-200 (PPI)

–
2)

• 1) 2)

• 1) 2)

• 1) 3)

MPI cable 11)

2)5)

2) 5)

3) 5)

MPI cable 11)

via MPI or PROFIBUS
(PG/OP communication)
on S7-200

•

via MPI or PROFIBUS
(PG/OP communication)
with S7-300, -400

• 2)

• 2)

• 2)

• 3)

MPI cable 11)

via PPI network (PPI)
with max. 1 x S7-200

–

• 1) 2)

• 1) 2)

• 1) 3)

PPI network 12)
(see Catalog ST 70
and IK PI)

via PPI network
(PG/OP communication)
with max. 4 x S7-200

• 2)

• 6)

–

–

PPI network 12)
(see Catalog ST 70
and IK PI)

via MPI or PROFIBUS network
(PG/OP communication)
with max. 4 x S7-200

• 2)

• 2) 5)

• 2) 5)

• 3) 5)

MPI or PROFIBUS
network 12)
(see Catalogs ST 70
and IK PI)

via MPI or PROFIBUS network
(PG/OP communication)
with max. 4 x S7-300, -400, WinAC

• 2)

• 2)

• 2)

• 3)

MPI or PROFIBUS
network 12)
(see Catalogs ST 70
and IK PI)

via Industrial Ethernet (TCP/IP)
(PG/OP communication)
with max. 4 x S7-200, -300, -400,
WinAC

– 7)

• 7) 8)

• 8) 9)

• 10)

Industrial Ethernet
(see Catalog IK PI)

•

•

•

• System interface possible
– System interface not possible
1)

Can only be interfaced with max. 1 x S7-200 via PPI (PPI);
network operation (parallel PG, etc.) possible

7)

Only Basic Panel PN, TP 177B DP/PN, OP 177B DP/PN,
Mobile Panel 177 PN

2)

Not Basic Panel PN, Mobile Panel 177 PN, Mobile Panel 277 IWLAN;

8)

Mobile Panel 177 PN, Mobile Panel 277 connection via special connecting
cable and junction box (see Mobile Panel);
Please refer to the manual for cable assignment

9)

Mobile Panel 277 IWLAN (wireless interface, see Mobile Panel)
Connection via integrated Industrial Ethernet interface; use the CP 1612
with a standard PC

Mobile Panel 177 DP, Mobile Panel 277 connection via special
connecting cable and junction box (see Mobile Panel);
Please refer to the manual for cable assignment
3)

Connection via integrated MPI/PROFIBUS interface; use the CP 5611 A2
with a standard PC.

10)

4)

Max. transmission rate 1.5 Mbit/s

11)

5)

Only on passive S7-200; OP 77B (MPI) also on active S7-200
Only OP 77B (MPI)

MPI cable 6ES7 901-0BF00-0AA0 (max. 187.5 Kbit/s) included in PG
scope of delivery (for download and test purposes only)

12)

Bus connector 6GK1 500-0EA02

6)

2/86

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
System interfaces with WinCC flexible
SIMATIC S5

■ Overview
A variety of interfaces differing in respect of type and
performance are available for linking SIMATIC HMI Panels to
SIMATIC S5 (not S5-150U). However, a feature common to all is
that from the point of view of the connected SIMATIC HMI Panel,
the connection is always a logical point-to-point one, i.e. there is
always a fixed assignment between a SIMATIC HMI Panel and a
PLC.
AS511 interface
(not for OP 77A, TP 177A, Basic Panel, Mobile Panel 177,
Mobile Panel 277)
S5-90U to -135U, -155U
(except CPU 922 < Version 9,
except CPU 928 [6ES5 928-3UA11],
except CPU 946/947 [6ES5 94•-3UA11],
except CPU 946/947 [6ES5 94•-3UA21],
except CPU 946/947 [6ES5 94•-3UA22] < Version 5)
The AS511 interface is implemented via the PG interface of
SIMATIC S5 and uses the associated CPU resources, that is, the
performance capability of the SIMATIC HMI Panel is determined
by the performance capability of the SIMATIC CPU used.

PROFIBUS DP interface
(not for OP 77A, TP 177A, Basic Panel, Mobile Panel 177 PN,
Mobile Panel 277 IWLAN)
S5-115U, -135U, -155U via IM 308C or
CP 5431 FMS/ DP (except CPU 922 < Version 9,
except CPU 928 [6ES5 928-3UA11],
except CPU 946/947 [6ES5 94•-3UA11],
except CPU 946/947 [6ES5 94•-3UA21],
except CPU 946/947 [6ES5 94•-3UA22] < Version 5)

2

The PROFIBUS DP interface supports the connection of:
• Up to 2 SIMATIC HMI Panels as SLAVES via a PROFIBUS
network to a SIMATIC S5-95U with integrated PROFIBUS DP/
master interface [6ES5 095-8ME01]
• Up to 30 SIMATIC HMI Panels as SLAVES via a PROFIBUS
network to a SIMATIC S5 with separate PROFIBUS DP/master
interface IM 308C, or CP 5431 FMS/DP
Communication between SIMATIC HMI Panels (DP slaves)
and SIMATIC S5 (DP master) runs via PROFIBUS DP message
frames in accordance with EN 50170 with higher-level
"HMI profile". A function block which must be called for each
connected SIMATIC HMI Panel is required in the PLC
(FB is included in scope of delivery).

Siemens ST 80 / ST PC · 2013

2/87

© Siemens AG 2013

Operator panels
System interfaces with WinCC flexible
SIMATIC S5

■ Overview (continued)
Controller

SIMATIC HMI

Target hardware (PROTOCOL)

OP 77A

OP 77B

TP 277

(physics)

TP 177A
Basic Panel

TP 177B DP
OP 177B DP

OP 277
Mobile Panel 277

TP 177B DP/PN
OP 177B DP/PN

Mobile Panel 277 IWLAN
MP 177

Mobile Panel 177 DP
Mobile Panel 177 PN

MP 277
MP 377

• 2)

–

2

WinCC flexible
Runtime

Connection via

•

6ES5 734-1BD201)
(3.2 m)

SIMATIC S5 (AS511)
S5-90U to 155U
except CPU 922 < version 9,

–

except CPU 928
(6ES5 928-3UA11)

6XV1 440-2A…
(see HMI accessories/
connecting cables)

except CPU 946/947
(6ES5 94.-3UA11,
6ES5 94.-3UA21,
6ES5 94.-3UA22 < version 5)
(TTY)
S5-90U to 155U
except CPU 922 < version 9,

–

• 3) 5)

• 3)

–

6AV6 671-8XJ000AX0

except CPU 928
(6ES5 928-3UA11)

(RS422-TTY adapter)

except CPU 946/947
(6ES5 94.-3UA11,
6ES5 94.-3UA21,
6ES5 94.-3UA22 < version 5)
(TTY)

(see HMI accessories/
connecting cables)

6XV1 440-2A…

SIMATIC S5 (PROFIBUS DP + HMI)
via PROFIBUS DP with
1 x S5-95U/L2-DP/master
(6ES5 095-8ME02)
via PROFIBUS DP with IM 308C
on S5-115U, -135U, -155U

–

•3)

•3)

•4)

–

•

3)

3)

4)

–

•3)

PROFIBUS4)
(see Catalog IK PI)

•

•

•3)

•4)

PROFIBUS4)
(see Catalog IK PI)

except CPU 922 < version 9,
except CPU 928
(6ES5 928-3UA11),
except CPU 946/947
(6ES5 94.-3UA11,
6ES5 94.-3UA21,
6ES5 94.-3UA22 < version 5)
via PROFIBUS DP with
CP 5431 FMS/DP on
S5-115U, -135U, -155U
except CPU 922 < version 9,
except CPU 928
(6ES5 928-3UA11),
except CPU 946/947
(6ES5 94.-3UA11,
6ES5 94.-3UA21,
6ES5 94.-3UA22 < version 5)

• System interface possible
– System interface not possible
1)

PC cable with integrated level converter RS 232/TTY

2)

OP 77B only

3)

WinCC flexible 2008 Service Pack 2 and higher

4)

Connection via integrated MPI/PROFIBUS interface: use the CP 5611 A2
for a standard PC.

5)

not for OP 77B; in this case the RS 232 interface is to be used.

2/88

Siemens ST 80 / ST PC · 2013

PROFIBUS4)
(see Catalog IK PI)

© Siemens AG 2013

Operator panels
System interfaces with WinCC flexible
SIMATIC 505

■ Overview
A variety of interfaces differing in respect of type and performance are available for linking SIMATIC HMI Panels to
SIMATIC 505.

PROFIBUS DP interface
(not for OP 77A, TP 177A, Basic Panel, Mobile Panel 177 PN,
Mobile Panel 277 IWLAN)

However, a feature common to all is that from the point of view of
the connected SIMATIC HMI Panel, the connection is always a
logical point-to-point one, that is, there is always a fixed
assignment between an HMI Panel and a PLC.

SIMATIC 505 PLC or SIMATIC 545, SIMATIC 555 with CP 5434
With the PROFIBUS DP interface, up to 30 SIMATIC HMI Panels
can be connected as SLAVES to one SIMATIC 545, 555 via a
PROFIBUS network, with plug-in PROFIBUS DP/master interface
type CP 5434.

NITP interface
(not for OP 77A, TP 177A, Basic Panel, Mobile Panel 177 PN,
Mobile Panel 277 IWLAN)

Communication between SIMATIC HMI Panels (DP slaves) and
SIMATIC 505 (DP master) runs via PROFIBUS DP message
frames in accordance with EN 50170 with higher-level "HMI
profile". An application ladder which must be called for each
connected SIMATIC HMI Panel is required in the PLC (example
of application ladder included in ProTool scope of delivery).

The NITP interface runs via the PG interface of the SIMATIC 505
and uses the associated CPU resources, that is, the performance capability of the SIMATIC HMI Panel is determined by the
performance capability of the SIMATIC CPU used.
Controller

SIMATIC HMI

Target hardware (PROTOCOL)
(physics)

OP 77A

OP 77B

TP 277

TP 177A

TP 177B DP

OP 277

Basic Panel

OP 177B DP

Mobile Panel 277

TP 177B DP/PN

Mobile Panel 277 IWLAN

OP 177B DP/PN

MP 177

Mobile Panel 177 DP

MP 277

Mobile Panel 177 PN

MP 377

–

• 1) 2)

• 1) 2)

PLC 545, 555
(RS 232)

–

1) 2)

1) 2)

PLC 535, 545/CPU 1101, 565T
(RS 422)

–

• 1)

• 1)

• 4)

See online help 6)

PLC 545/CPU 1102, 555
(RS 422)

–

• 1)

• 1)

• 4)

See online help 6)

• 1)

• 1)

• 5)

PROFIBUS 7)

WinCC flexible
Runtime

Connection via

•

PPX: 2601 094-8001 3)

SIMATIC 505 (NITP)
PLC 525, 535, 565T
(RS 232)

See online help 6)
•

•

PPX: 2601 094-8001 3)

•

6XV1 440-2K…
(see HMI accessories/
connecting cables)

SIMATIC 505 (PROFIBUS DP + HMI)
via PROFIBUS DP to
1 x PLC 545, 555 with CP 5434

–

(see Catalog IK PI)

• System interface possible
– System interface not possible
1)

Not Mobile Panel 177 PN, Mobile Panel 277 IWLAN Mobile Panel 177 DP,

Mobile Panel 277 connection via special connecting cable and
junction box (see Mobile Panel); see manual for cable assignment.
2)

The RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is required for Touch
Panels, Operator Panels, and Multi Panels

3)

A standard adapter (9-/25-pin male) is required on the PLC
A commercially available level converter (RS 232/RS 422) is required on
the PC
Connection via integrated MPI/PROFIBUS interface, use the CP 5611 A2
with a standard PC

4)
5)
6)

Detailed information (cable assignment) can be found in the online help for
WinCC flexible and in the Communication User Manual for Windows-based
systems

7)

Bus connector 6GK1 500-0EA02

Siemens ST 80 / ST PC · 2013

2/89

2

© Siemens AG 2013

Operator panels
System interfaces with WinCC flexible
PLCs from other manufacturers

■ Overview
Allen Bradley
Three communication protocols are available for the interface
between SIMATIC TP/OP/MP and Allen Bradley:

2

DF1 interface
(not on OP 73, Basic Panel PN, Mobile Panel 177 PN,
Mobile Panel 277 IWLAN)
This communication between SIMATIC TP/OP/MP and Allen
Bradley runs on the basis of the DF1 protocol; the following have
been tested and released:
• Direct connection between a SIMATIC TP/OP/MP and the PG
interface on an Allen Bradley PLC5 or the DF1 interface on an
Allen Bradley SLC500 (point-to-point link)
• The integration of SIMATIC TP/OP/MP via Allen Bradley KF2
gateway in an Allen Bradley DH+ network. Communication is
possible between SIMATIC TP/OP/MP and up to 4 SLC 500
PLCs or PLC5s (multipoint link from the point of view of the
SIMATIC TP/OP/MP; only one connection possible with TP
170A)
• The integration of SIMATIC TP/OP/MP via Allen Bradley KF3
gateway in an Allen Bradley DH485 network. Communication
is possible between SIMATIC TP/OP/MP and up to 4 PLCs
type SLC 500 or MicroLogix (multipoint link from the point of
view of the SIMATIC TP/OP/MP; only one connection possible
with TP 170A)
DH485 interface
(not on OP 73, OP 77A, TP 177A, Basic Panel,
Mobile Panel 177 PN, Mobile Panel 277 IWLAN)
This communication between SIMATIC TP/OP/MP and Allen
Bradley runs on the basis of the DH485 protocol; the following
have been tested and released:
• Direct connection between a SIMATIC TP/OP/MP and an Allen
Bradley SLC500 or MicroLogix (point-to-point link)
• The integration of SIMATIC TP/OP/MP via Allen Bradley AIC
adapter in an Allen Bradley DH485 network. Communication
is possible between SIMATIC TP/OP/MP and up to 4 PLCs
type SLC 500 or MicroLogix (multipoint link from the point of
view of the SIMATIC TP/OP/MP; only one connection possible
with TP 170A)
• The integration of SIMATIC TP/OP/MP (not PC with
WinCC flexible Runtime) in an Allen Bradley DH485 network.
Communication is possible between SIMATIC TP/OP/MP and
up to 4 PLCs type SLC 500 or MicroLogix (multipoint link from
the point of view of the SIMATIC TP/OP/MP; only one
connection possible with TP 170A)
Ethernet IP protocol
(not on OP 73, OP 77A, TP 177A, Basic Panel, OP 77B,
TP 177B DP, OP 177B DP, Mobile Panel 177 DP,
Mobile Panel 277 IWLAN)
This communication between SIMATIC TP/OP/MP and
Allen Bradley runs based on the Ethernet IP protocol;
SIMATIC TP/OP/MP integration is tested and released in an
Ethernet IP network. Communication is possible between
SIMATIC TP/OP/MP and up to 4 ControlLogix or
CompactLogix PLCs (multipoint link from the point of view
of the SIMATIC TP/OP/MP)

2/90

Siemens ST 80 / ST PC · 2013

GE-Fanuc
(not on OP 73, OP 77A, TP 177A, Basic Panel,
Mobile Panel 177 PN, Mobile Panel 277 IWLAN)
Communication between SIMATIC TP/OP/MP and GE-Fanuc
runs on the basis of the SNP protocol; the following have been
tested and released:
• Direct connection between a SIMATIC TP/OP/MP and
a GEF 90-Micro, 90-30 or 90-70 (point-to-point link)
• Integration of SIMATIC TP/OP/MP in an RS 422 network
via adapter. Communication is possible between
SIMATIC TP/OP/MP and up to 4 GEF 90-Micro, 90-30 or
90-70 PLCs (multipoint link from the point of view of the
SIMATIC TP/OP/MP; only one connection possible with
TP 170A)
• The integration of SIMATIC TP/OP/MP (not PC with ProTool/
Pro Runtime or WinCC flexible Runtime) in an RS 422 network.
Communication is possible between SIMATIC TP/OP/MP and
up to 4 GEF 90-Micro, 90-30 or 90-70 PLCs (multipoint link
from the point of view of the SIMATIC TP/OP/MP; only one
connection possible with TP 170A)
LG GLOFA GM
(not on OP 73, OP 77A, TP 177A, Basic Panel,
Mobile Panel 177 PN, Mobile Panel 277 IWLAN)
Communication between SIMATIC TP/OP/MP and
LG GLOFA GM runs on the basis of the dedicated protocol;
the following have been tested and released:
• Connection between a SIMATIC TP/OP/MP and an
LG GLOFA GM with Cnet module (point-to-point link)
• Integration of SIMATIC TP/OP/MP in an RS 422 network via
LG Cnet module. Communication is possible between
SIMATIC TP/OP/MP (not PC with ProTool/Pro Runtime) and up
to 4 LG GLOFA GM PLCs on the network (multipoint link from
the point of view of the SIMATIC TP/OP/MP; only one
connection possible with TP 170A)
Mitsubishi
(not with OP 73, Basic Panel, Mobile Panel 177 PN,
Mobile Panel 277 IWLAN)
Two communication protocols are available for the interface
between SIMATIC TP/OP/MP and Mitsubishi:
FX protocol
This communication between SIMATIC TP/OP/MP and
Mitsubishi runs on the basis of the FX protocol; the direct
connection between a SIMATIC TP/OP/MP and the PG interface
of a Mitsubishi FX/FX0 (logical point-to-point link) has been
tested and released.
MP4 protocol
This communication between SIMATIC TP/OP/MP and
Mitsubishi runs on the basis of the MP4 protocol;
the following have been tested and released:
• Direct connection between a SIMATIC TP/OP/MP and a
Mitsubishi Series FX, Series A or Series Q (point-to-point link)
• Integration of SIMATIC TP/OP/MP in an RS 422 network via
Mitsubishi converter FX-48SC-IF. Communication is possible
between SIMATIC TP/OP/MP and up to 4 Series FX, Series A
or Series Q PLCs (multipoint link from the point of view of the
SIMATIC TP/OP/MP; only one connection possible with
TP 170A)
• The integration of SIMATIC TP/OP/MP (not PC with ProTool/
Pro Runtime or WinCC flexible Runtime) in an RS 422 network.
Communication is possible between SIMATIC TP/OP/MP and
up to 4 Series FX, Series A or Series Q PLCs (multipoint link
from the point of view of the SIMATIC TP/OP/MP; only one
connection possible with TP 170A)

© Siemens AG 2013

Operator panels
System interfaces with WinCC flexible
PLCs from other manufacturers

■ Overview (continued)
Modicon
Two communication protocols are available for the interface
between SIMATIC TP/OP/MP and Modicon:

Omron
(not with OP 73, Basic Panel PN, Mobile Panel 177 PN,
Mobile Panel 277 IWLAN)

Communication between SIMATIC TP/OP/MP and Modicon runs
on the basis of the Modbus protocol; the following have been
tested and released:
• Direct connection between a SIMATIC TP/OP/MP and the
Modbus interface on a Modicon 984, TSX Quantum or
TSX Compact (point-to-point link)
• The integration of a SIMATIC TP/OP/MP via Modicon
Modbus PLUS bridge BM85-000 or the bridge function of a
MODICON 984-145 or TSX Quantum into a Modbus PLUS
network and communication between SIMATIC TP/OP/MP
(Modbus/master) and up to 4 Modicon 984 or TSX Quantum
PLCs (Modbus/slave) on the network (multipoint link from the
point of view of the SIMATIC TP/OP/MP; only one connection
possible with TP 170A).

Communication between SIMATIC TP/OP/MP and Omron runs
on the basis of the Link/MultiLink protocol; the following have
been tested and released:
• Direct connection between a SIMATIC TP/OP/MP and an
Omron Sysmac C, Sysmac  or Sysmac CV (point-to-point
link)
• Integration of SIMATIC TP/OP/MP in an RS 422 network
via Omron converter NT-AL001. Communication is possible
between SIMATIC TP/OP/MP and up to 4 Sysmac C,
Sysmac  or Sysmac CV PLCs (multipoint link from the point
of view of the SIMATIC TP/OP/MP; only one connection
possible with TP 170A)
• The integration of SIMATIC TP/OP/MP (not PC with ProTool/
Pro Runtime or WinCC flexible Runtime) in an RS 422 network.
Communication is possible between SIMATIC TP/OP/MP and
up to 4 Sysmac C, Sysmac  or Sysmac CV PLCs (multipoint
link from the point of view of the SIMATIC TP/OP/MP; only one
connection possible with TP 170A)

Modbus TCP/IP protocol
(not for OP 73, OP 77A, TP 177A, Basic Panel DP, OP77B,
TP 177B DP, OP 177B DP, Mobile Panel 177 DP,
Mobile Panel 277 IWLAN)

Telemecanique
(not on OP 73, OP 77A, TP 177A, Basic Panel,
Mobile Panel 177 PN, Mobile Panel 277 IWLAN,
WinCC flexible Runtime)

This communication between SIMATIC TP/OP/MP and Modicon
runs on the basis of the Modbus TCP/IP protocol; the following
have been tested and released:
• Integration of SIMATIC TP/OP/MP into a Modbus TCP/IP
network. Communication is possible between
SIMATIC TP/OP/MP and up to 4 Momentum, TSX Micro
( TSX 37 ), TSX Premium ( TSX 57 ), TSX Unity Premium,
TSX Quantum or TSX Unity Quantum PLCs (multipoint link
from the point of view of the SIMATIC TP/OP/MP)
• The communication between SIMATIC TP/OP/MP via
TCP/IP Modbus Plus Bridge 174 CEV 200 40 / Modbus PLUS
network to Modicon 984 (except 984A, 984B, 984X ),
TSX Compact, TSX Quantum or TSX Unity Quantum (multipoint link from the point of view of the SIMATIC TP/OP/MP)

Data exchange between SIMATIC TP/OP/MP and
Telemecanique runs on the basis of the UNI-TELWAY protocol;
the following have been tested and released:
• Connection between a SIMATIC TP/OP/MP (UNI-T/slave) via
Telemecanique outlet TSX SCA62 and a Telemecanique
TSX 17 or TSX 47/67/87/107 (UNI-T/master)
(logical point-to-point link)
• Connection between a SIMATIC TP/OP/MP (UNI-T/slave) via
Telemecanique outlets TSX SCA62 + ACC01 and a Telemecanique TSX 37 or TSX 57 (UNI-T/master) (logical point-to-point
link)
• The integration of a SIMATIC TP/OP/MP via Telemecanique
outlet TSX SCA62 in a UNI-TELWAY network and communication between SIMATIC TP/OP/MP (UNI-T/slave) and up to
4 TSX 17, TSX 37, TSX 57 or TSX 47/67/87/107 PLCs (UNI-T/
master or slave) on the network (multipoint link from the point
of view of the SIMATIC TP/OP/MP; only one connection
possible with TP 170A).

Modbus protocol
(not for OP 73, Basic Panel PN, Mobile Panel 177 PN,
Mobile Panel 277 IWLAN)

Siemens ST 80 / ST PC · 2013

2/91

2

© Siemens AG 2013

Operator panels
System interfaces with WinCC flexible
PLCs from other manufacturers

■ Overview (continued)
Controller

SIMATIC HMI

Target hardware (PROTOCOL)
(physics)

OP 77A

Basic Panel

TP 177A

2

OP 77B

TP 277

TP 177B DP
OP 177B DP
TP 177B DP/PN
OP 177B DP/PN

OP 277
Mobile Panel
277 / 277 IWLAN
MP 177

Mobile Panel
177 DP / 177 PN

MP 277
MP 377

WinCC flexible
Runtime

Connection via

•

1747 CP3 7)

Allen Bradley (DF1)
• 1) 2)

• 1) 2)

• 1) 2)

• 1) 2)

•

1) 2)

•

1) 2)

•

1) 2)

•

1) 2)

•

1)

•

1)

•

1)

•

1)

–

See FAQ 9)

via KF2 gateway and
DH+ network with up to
4 x SLC 50/04 or
PLC 5/11,20,30,40,60,80 (RS 232)

•

1) 2)

•

1) 2)

•

1) 2)

•

1) 2)

•

1784 CP10 7) 8)

via KF2 gateway and
DH+ network with up to
4 x SLC 50/04 or
PLC 5/11,20,30,40,60,80 (RS 422)

• 1)

• 1)

• 1)

• 1)

–

See FAQ 9)

via KF3 gateway and
DH485 network with up to
4 x SLC 500/00,01,02,03,04,05 or
MicroLogix (RS 232)

• 1) 2)

• 1) 2)

• 1) 2)

• 1) 2)

•

1784 CP10 7)8)

SLC 500/03,04,05 or MicroLogix
(RS 232)
PLC 5/11,20,30,40,60,80 (RS 232)

See FAQ 9)
•

1784 CP10 7)
See FAQ 9)

PLC 5/11,20,30,40,60,80 (RS 422)

See FAQ 9)

See FAQ 9)

Allen Bradley (DH485)
SLC 500/03,04,05 or
MicroLogix (RS 232)

–

–

• 1) 2)

• 1) 2)

•

See FAQ 9)

via AIC adapter and
DH485 network with up to
4 x SLC 500 or MicroLogix
(RS 232)

–

–

• 1) 2)

• 1) 2)

•

See FAQ 9)

via DH485 network with up to
4 x SLC 500/00,01,02,03,04,05 or
MicroLogix (RS 485)

–

–

• 1)

• 1)

–

See FAQ 9)

–

–

• 3) 4)

• 4)

•

See FAQ 9)

Allen Bradley (Ethernet IP)
via Ethernet IPnetwork
with up to 4 x ControlLogix
(1756-L61, 1756-L62, 1756-L63,
1756-L64, 1756-L65, each with
Ethernet module 1756-ENBT)
GuardLogix
(1756-L61S, 1756-L62S,
1756-L61S, each with Ethernet
module 1756-ENBT) or
CompactLogix
(1769-L32E, 1769-L35E, each with
Ethernet interface onboard

• System interface possible
– System interface not possible
1)

Not Basic Panel PN, Mobile Panel 177 PN, Mobile Panel 277 IWLAN;
Mobile Panel 177 DP, Mobile Panel 277 connection via special connecting
cable and junction box (see Mobile Panel); see manual for cable
assignment.

2)

The RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is required for
Basic Panel, Touch Panel, Operator Panel, and Multi Panel

3)

Only TP 177B DP/PN, OP 177B DP/PN, Mobile Panel 177 PN

4)

Mobile Panel 177 PN, Mobile Panel 277 connection via special connecting
cable and junction box (see Mobile Panel); see manual for cable
assignment.
Not Mobile Panel 277 IWLAN (wireless interface, see Mobile Panel)

5)
6)

Connection via integrated Industrial Ethernet interface; use the
CP 1612 with a standard PC

7)

Allen Bradley PC cable
Cable for connection to KF2/KF3 gateway; a gander changer
(25-pin socket/25-pin socket) is required on the gateway side

8)

2/92

Siemens ST 80 / ST PC · 2013

9)

Detailed information (cables used) see FAQ:
http://support.automation.siemens.com/WW/view/en/29034071
in the online help for WinCC flexible and in the Communication User
Manual for Windows-based systems

© Siemens AG 2013

Operator panels
System interfaces with WinCC flexible
PLCs from other manufacturers

■ Overview (continued)
Controller

SIMATIC HMI

Target hardware (PROTOCOL)
(physics)

OP 77A

Basic Panel

TP 177A

OP 77B

TP 277

TP 177B DP
OP 177B DP

OP 277
Mobile Panel 277

TP 177B DP/PN
OP 177B DP/PN

Mobile Panel 277
IWLAN

Mobile Panel 177 DP
Mobile Panel 177 PN

MP 177
MP 277

WinCC flexible
Runtime

Connection via

2

MP 377
GE-Fanuc (SNP)
GEF 90-Micro, 90-30, 90-70
(RS 232)

–

–

• 1) 2)

• 1) 2)

•

See FAQ 4)

via adapter with up to 4 x GEF
90-Micro, 90-30, 90-70 (RS 232)

–

–

• 1) 2)

• 1) 2)

•

See FAQ 4)

via adapter with up to 4 x GEF
90-Micro, 90-30, 90-70 (RS 422)

–

–

• 1)

• 1)

–

See FAQ 4)

GLOFA-GM with Cnet module
(RS 232)

–

–

• 1) 2)

• 1) 2)

•

See FAQ 4)

With up to 4 x GLOFA-GM with
Cnet module (RS 422)

–

–

• 1)

• 1)

–

See FAQ 4)

–

–

–

–

•

SC-09 6)

–

See FAQ 4)

LG GLOFA (Dedicated)

Mitsubishi FX
FX0 (RS 422)

FX0n, FX1n, FX2n (RS 422)

–

–

•

–

–

–

1)

•

1)

•

SC-09 6)

1)

–
–

See FAQ 4)
SC-09 6)

–
1)

–
• 1) 6)

–
• 1) 6)

•
–

• Series FX
with communications module
• Series A (AnN, AnA, AnU, AnS)
with interface module
• Series Q (QnA, QnAS) with
interface module (RS 232)

–

–

• 1) 2)

• 1) 2)

•

See FAQ 4)

via FX-48SC-IF converter
with up to 4 PLCs
• Series FX with communications
module
• Series A (AnN, AnA, AnU, AnS)
with interface module
• Series Q (QnA, QnAS) with
interface module (RS 232)

–

–

• 1) 2)

• 1) 2)

•

See FAQ 4)

with up to 4 PLCs
• Series FX
with communications module
• Series A (AnN, AnA, AnU, AnS)
with interface module
• Series Q (QnA, QnAS) with
interface module (RS 422)

–

–

• 1)

• 1)

–

See FAQ 4)

• FX1N-14MR-DS
• FX1S-10MR-DS
• FX2N-16MR-DS (RS 422)

•
–

Mitsubishi (MP4)

• System interface possible
– System interface not possible
1)

Not Mobile Panel 177 PN, Mobile Panel 277 IWLAN; Mobile Panel 177 DP,
Mobile Panel 277 connection via special connecting cable and junction
box (see Mobile Panel); see manual for cable assignment.

2)

The RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is required for Touch
Panels, Operator Panels, and Multi Panels

3)

With connection using a Mitsubishi PC cable, an 15-pin/9-pin adapter
6XV1 440-2UE32 is required

4)

Detailed information (cables used) see FAQ:
http://support.automation.siemens.com/WW/view/de/29034071 in the
online help for WinCC flexible and in the Communication User Manual for
Windows-based systems

5)

Mitsubishi PC cable with integrated level converter RS 232/RS 422
WinCC flexible 2008 Service Pack 2 and higher

6)

Siemens ST 80 / ST PC · 2013

2/93

© Siemens AG 2013

Operator panels
System interfaces with WinCC flexible
PLCs from other manufacturers

■ Overview (continued)
Controller

SIMATIC HMI

Target hardware (PROTOCOL)
(physics)

OP 77A

Basic Panel

TP 177A

2

OP 77B

TP 277

TP 177B DP
OP 177B DP

OP 277
Mobile Panel 277

TP 177B DP/PN
OP 177B DP/PN

Mobile Panel 277
IWLAN

Mobile Panel 177 DP
Mobile Panel 177 PN

MP 177
MP 277

WinCC flexible
Runtime

Connection via

MP 377
Modicon (Modbus)
984-120, 130, 131, 141, 145,
380, 381, 185, 480, 485, 680,
685, 780, 785, or
TSX-Quantum-CPU 113, 213,
424, 434, 534 (RS 232)

• 1) 2)

• 1) 2)

• 1) 2)

• 1) 2)

•

See FAQ 7)

via bridge BM85-000 or
PLC with bridge function. /
Modbus PLUS network
with up to 4 x 984-120, ... or
TSX Quantum - CPU 113, or
TSX Contact
(RS 232)

• 1) 2)

• 1) 2)

• 1) 2)

• 1) 2)

•

See FAQ 7)

TSX Compact (RS 232)

• 1) 2)

• 1) 2)

• 1) 2)

• 1) 2)

•

See FAQ 7)

via Modbus TCP/IP network
with up to 4 x
TSX Unity Quantum or
TSX Unity Premium or
TSX Quantum or
TSX Quantum with TCP/IP
module 140 NOE 771 01 or
TSX Unity Premium or
TSX Premium with
TCP/IP module TSX ETY 110
or TSX Micro with
TCP/IP module TSX ETY 410
or Momentum with
CPU adapter 171 CCC 980 30

–

–

• 3) 4)

• 4) 5)

•

via TCP/IP ModbusPlus bridge
174 CEV 200 40 / Modbus PLUS
network with up to 4 x
TSX Unity Quantum or
TSX Quantum or
TSX Compact or 984-120, ...
(except 984A, 984B, 984X )

–

–

• 3) 4)

• 4) 5)

•

via Modbus TCP/IP network
with up to 4 x
TSX Unity Quantum or
TSX Unity Premium or
TSX Quantum or
TSX Quantum with TCP/IP
module 140NOE 771 01 or
TSX Unity Premium or
TSX Premium with TCP/IP
module TSX ETY 110 or
TSX Micro with TCP/IP module
TSX ETY 410 or
Momentum with CPU adapter
171 CCC 980 30

• 3) 8)

• 3) 8)

–

–

–

via TCP/IP ModbusPlus Bridge
174 CEV 200 40 / Modbus PLUS
network with up to 4 x
TSX Unity Quantum or
TSX Quantum or
TSX Compact

• 3) 8)

• 3) 8)

–

–

–

Modicon (Modbus TCP/IP)

• System interface possible
– System interface not possible
1)

Not Mobile Panel 177 PN, Mobile Panel 277 IWLAN; Mobile Panel 177 DP,
Mobile Panel 277 connection via special connecting cable and
junction box (see Mobile Panel); see manual for cable assignment.

5)

2)

The RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is required for
Touch Panels, Operator Panels, and Multi Panels

7)

3)

Only TP 177B DP/PN, OP 177B DP/PN, Mobile Panel 177 PN

4)

Mobile Panel 177 PN, Mobile Panel 277 connection via special connecting
cable and junction box (see Mobile Panel); see manual for cable
assignment.

2/94

Siemens ST 80 / ST PC · 2013

6)

8)

Not Mobile Panel 277 IWLAN (wireless interface, see Mobile Panel)
Connection via integrated Industrial Ethernet interface; use the CP 1612
with a standard PC
Detailed information (cables used) see FAQ:
http://support.automation.siemens.com/WW/view/en/29034071 in the
online help for WinCC flexible and in the Communication User Manual for
Windows-based systems
WinCC flexible 2008 Service Pack 2 and higher

© Siemens AG 2013

Operator panels
System interfaces with WinCC flexible
PLCs from other manufacturers

■ Overview (continued)
Controller

SIMATIC HMI

Target hardware (PROTOCOL)
(physics)

OP 77A

Basic Panel

TP 177A

OP 77B

TP 277

TP 177B DP
OP 177B DP

OP 277
Mobile Panel 277

TP 177B DP/PN
OP 177B DP/PN

Mobile Panel 277
IWLAN

Mobile Panel 177 DP
Mobile Panel 177 PN

MP 177
MP 277

WinCC flexible
Runtime

Connection via

2

MP 377
Omron (Link/MultiLink)
–

–

• 1) 2)

• 1) 2)

•

See FAQ 3)

–

–

• 1) 2)

• 1) 2)

•

See FAQ 3)

–

–

• 1)

• 1)

–

See FAQ 3)

• 1) 4)

• 1) 4)

–

–

–

via TSX SCA62 outlet with
–
TSX 17 or TSX 47/67/87/107 (RS 485)

–

• 1)

• 1)

–

See FAQ 3)

via TSX SCA62 + ACC01 outlets
with TSX 37/57 (RS 485)

–

–

• 1)

• 1)

–

See FAQ 3)

via TSX SCA62 outlet and
UNI-TELWAY network with
4 x TSX 17 or TSX 37/57 (+ACC 01)
or TSX 47/67/87/107 (RS 485)

–

–

• 1)

• 1)

–

See FAQ 3)

• SYSMAC C
(except CPU CQM1 – CPU 11/21)
• SYSMAC Alpha
• SYSMAC CV (RS 232)
via NT-AL001 converter
with up to 4 PLCs
• SYSMAC C
(except CPU CQM1 – CPU 11/21)
• SYSMAC Alpha
• SYSMAC CV (RS 232)
with up to 4 PLCs
• SYSMAC C
(except CPU CQM1 – CPU 11/21)
• SYSMAC Alpha
• SYSMAC CV (RS 422)
• CP1L-L14DT1-D
• C1H-Y20DT-D
• CJ1M CPU11
Telemecanique (UNI-TELWAY)

• System interface possible
– System interface not possible
1)

2)
3)

4)

Not Mobile Panel 177 PN, Mobile Panel 277 IWLAN; Mobile Panel 177 DP,
Mobile Panel 277 connection via special connecting cable and junction
box (see Mobile Panel); see manual for cable assignment.
The RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is required for
Touch Panels, Operator Panels, and Multi Panels
Detailed information (cables used) see FAQ:
http://support.automation.siemens.com/WW/view/en/29034071 in the
online help for WinCC flexible and in the Communication User Manual for
Windows-based systems
WinCC flexible 2008 Service Pack 2 and higher

Siemens ST 80 / ST PC · 2013

2/95

© Siemens AG 2013

Operator panels
SIMATIC HMI accessories
General HMI accessories

■ Overview
The specially coordinated range of accessories supplements
the SIMATIC HMI core products perfectly. Industrial Hub 4 can
be used, for example, to make a USB port available to the user
exactly where it is required. Touch pens can be used to operate
extremely small buttons, and they also ensure that the display
stays clean for longer.

2

SIMATIC HMI accessories can also be used in non-Siemens
devices; see the technical specifications for more detailed information.
General SIMATIC HMI accessories for all currently available
Panels are listed in this chapter; the full range of SIMATIC HMI
accessories is available in the Mall and in our other online
media.

Industrial USB Hub 4

Touchscreen stylus and touch pen

2/96

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
SIMATIC HMI accessories
Industrial USB Hub 4

■ Overview
• The Industrial USB Hub 4 is used as a USB port extender
(4 in 1) for the connection of peripheral devices to USB 2.0
interfaces of Comfort Panels, Multi Panels, IPCs, and standard
PCs.
• The Industrial USB Hub 4 (IP65 degree of protection on the
front, service kit may be required) can also be mounted
directly in a control cabinet.
• With the USB Hub 4, the USB port can be moved forwards to
the control cabinet door, making it accessible without opening
the cabinet door
• The USB Hub 4 can also be mounted on a standard mounting
rail in the control cabinet, in which case it serves as a simple
interface multiplier

■ Technical specifications
6AV6671-3AH00-0AX0

6AV6671-3AH00-0AX0

Industrial USB Hub 4
Installation type/mounting
Mounting rail installation possible
Mounting in landscape format
possible

Yes; Standard - DIN rail
Yes

Supply voltage
Type of supply voltage

24 V DC

Rated voltage/DC

24 V

permissible range, lower limit (DC)

20.4 V

permissible range, upper limit (DC)

28.8 V

Interfaces
Number of USB interfaces

4; Type USB 2.0, 500 mA each;
e.g. connection of mouse,
keyboard, printer, USB stick,
USB IPC flash drive

Industrial USB Hub 4
Ambient conditions
Operating temperature
• Operation (vertical installation)
- in vertical mounting position/
minimum
- in vertical mounting position/
maximum

0 °C to +50 °C
0 °C
50 °C

Storage/transport temperature
• Min.
• max.

-20 °C
60 °C

Relative humidity
• max. relative humidity

90 %

Mechanics/material
Type of housing (front)
• Plastic

Yes
212 mm

Degree and class of protection
Type of protection

20

Dimensions
Width of the housing front

IP (at the front)

65

Height of housing front

156 mm

Depth/installation dimension

50 mm

Weight
Weight without packaging

460 g

Standards, approvals, certificates
CE

Yes

Scope of supply
Delivery unit in items

1; Content: 1 X USB Hub 4,
10 x plastic mounting clip,
1 x female 2-pin connector

other
Note:

■ Ordering data

Order No.

Industrial USB Hub 4
4 x USB 2.0, IP65, for control cabinet door or standard rail, for use
with MP 177/MP 277/MP 377, Panel
PCs, HMI IPCs and standard PCs

6AV6671-3AH00-0AX0

Service set for Industrial USB
Hub 4 (incl. IP65 expansion)

See HMI accessories service sets,
from page 2/118

for access to the USB interface of
a built-in device without having to
open the control cabinet, mounting
on standard rail possible, suitable
for standard USB interfaces

■ More information
Note for SIMATIC Panel PCs
The Industrial USB Hub 4 is approved for the Windows CE/2000/
XP/Windows 7 operating systems. The appropriate drivers are
supplied with the operating system software.

Siemens ST 80 / ST PC · 2013

2/97

2

© Siemens AG 2013

Operator panels
SIMATIC HMI accessories
Touch pen and touch stylus

■ Overview
If you are working with gloves, touch pens are often extremely
useful when operating touch displays. They protect the display
from dirt and scratching during operation and use. They are also
useful for operating small buttons or input fields accurately.

2

Optional package: Touchscreen stylus and touch pen

■ Technical specifications
6AV7672-1JB00-0AA0
Touch pen, thick, resistive technology

6AV6645-7AB14-0AS0
Touch pen, thin, resistive technology

Installation type/mounting
Wall mounting/direct mounting possible

Yes; Terminal holder can be attached

Yes; using 40 cm retaining cord

Standards, approvals, certificates
CE

Yes

Yes

Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.

55 °C
0 °C

55 °C
0 °C

Storage/transport temperature
• Min.
• max.

-20 °C
70 °C

-20 °C
70 °C

Relative humidity
• max. relative humidity

90 %

90 %

Mechanics/material
Screw type
• Torx

Yes

Plastic

Yes

Yes

Dimensions
Height

155 mm; Length

125 mm; Length

Thickness

20 mm; Diameter

8 mm; Diameter

Scope of supply
Delivery unit in items

1; Optional for extension units of the PRO devices

5; Incl. retaining cord for Mobile Panel 277 10"

for resistive touch screens, optimized for operating
while wearing gloves

for resistive touch screens

other
Note:

■ Ordering data
Touch stylus

Order No.
6AV7672-1JB00-0AA0

This catalog only includes accessories for current products.

for Panels, Panel PC, Touch Monitor
and other touch applications,
including screw-on wall holder
• 1 unit
Touch pen

The complete range of accessories can be found in the Mall:
https://eb.automation.siemens.com
6AV6645-7AB14-0AS0

Specially designed for
Mobile Panel 277 10",
but also other touch displays,
including attachment cord
• 5 units

2/98

Note:

Siemens ST 80 / ST PC · 2013

or on our SIMATIC Support pages:
http://support.automation.siemens.com

© Siemens AG 2013

Operator panels
Mobile Panel accessories
SIMATIC Mobile Panel accessories

■ Overview
General Mobile Panel accessories, such as service sets and
protective membranes, are listed in the respective accessories
section.
Special Mobile Panel accessories are listed in the following
section.
System components for SIMATIC HMI Mobile Panels can be
found directly under the respective Mobile Panel in the products
section.

Mobile Panel accessories

Siemens ST 80 / ST PC · 2013

2/99

2

© Siemens AG 2013

Operator panels
Mobile Panel accessories
Power supply unit

■ Overview
The external power supply for the Mobile Panel IWLAN is
intended for laboratory and office operation.
Suitable SITOP power supplies are available for use with
machinery and plants.

2

■ Technical specifications
6AV6671-5CN00-0AX2

6AV6671-5CN00-0AX2

Power pack, external,
Mobile Panel IWLAN

Power pack, external,
Mobile Panel IWLAN

Supply voltage
Type of supply voltage

100-240 V AC

Rated voltage/DC

12 V; Output side

Input current
Current consumption (rated value)

1.5 A; 50-60 Hz

Output current
each output

5A

Power
Output power

60 W

Interfaces
HMI-side interface
EMC
Emission of radio interference
acc. to EN 55 011
• Emission of radio interferences
acc. to EN 55 011 (limit class A)
Standards, approvals, certificates
CE

Connector 5.5 mm jack ( -) /
2.1 mm pin ( +) 12 V DC

Yes; EN61000-4-2,3,4,5,6,8,11
light industry level
Yes; UL69950, TÜVEN600950-1,
BSMI CNS14336,
CCC GB4942 approved

Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.

50 °C
-10 °C

Storage/transport temperature
• Min.
• max.

-20 °C
85 °C

Relative humidity
• max. relative humidity

90 %

Vibrations
• Vibration
• Frequency

2 g; 10 min./1 cycle
500 Hz; 10~500 Hz

Mechanics/material
Type of housing (front)
• Plastic

Yes

Dimensions
Width

125 mm

Height

50 mm

Thickness

31.5 mm

Weight
Weight without packaging

305 g

Scope of supply
Delivery unit in items

■ Ordering data

4; AC cable for EU, US, UK and JP

other
Note:

for Mobile Panel IWLAN

Note:
This catalog only includes accessories for current products.
6AV6671-5CN00-0AX2

Only suitable for operation under
laboratory/office conditions.

2/100

Number of sets

Order No.

Accessories for
Mobile Panel 277(F) IWLAN
Power supply unit, external,
Mobile Panel IWLAN

1; Incl. AC and DC connecting
cable

Siemens ST 80 / ST PC · 2013

The complete range of accessories can be found in the Mall:
https://eb.automation.siemens.com
or on our SIMATIC Support pages:
http://support.automation.siemens.com

© Siemens AG 2013

Operator panels
Mobile Panel accessories
Additional accessories

■ Overview

■ Technical specifications

Installation type/mounting
Mounting in portrait format
possible

6AV6574-1AG044AA0

Wall-mounting
bracket
Mobile Panel

Spare key
Mobile Panel

2

Yes

Mounting in landscape format
possible

No

Standards, approvals,
certificates
CE

Yes

Yes

55 °C

55 °C

0 °C

0 °C

Storage/transport temperature
• Min.
• max.

-20 °C
70 °C

-20 °C
70 °C

Relative humidity
• max. relative humidity

90 %

90 %

Ambient conditions
Operating temperature
• Operating temperature range,
max.
• Operating temperature range,
min.

Wall-mounting bracket for Mobile Panel, front view

6AV6574-1AF044AA0

Mechanics/material
Sheet steel

Yes; Handle made
of plastic

Type of housing (front)
• Sheet steel

Yes; Powder-coated

Dimensions
Width

200 mm

35 mm

Height

230 mm

18 mm

Thickness
Depth
Weight
Weight without packaging

Spare keys for Mobile Panel
Scope of supply
Delivery unit in items
other
Note:

4 mm
25 mm;
Constructive
550 g; 880 g incl.
cable holder

30 g

1; Color: Black

10; Coupled with
key ring

Mobile Panel 170,
Mobile Panel 177,
Mobile Panel 277
IWLAN, Mobile
Panel 277F IWLAN,
without mounting
parts

For all
Mobile Panels with
key-operated switch

Moby D data card transponder

Siemens ST 80 / ST PC · 2013

2/101

© Siemens AG 2013

Operator panels
Mobile Panel accessories
Additional accessories

■ Ordering data

2

Order No.

Wall mounting bracket
for Mobile Panels
metal, without mounting accessories, suitable for all Mobile Panels
• 1 unit

6AV6574-1AF04-4AA0

Replacement keys
for Mobile Panels
metal/plastic, for all Mobile Panels,
two linked by keyring
• 10 units

6AV6574-1AG04-4AA0

SCALANCE
SCALANCE W-788 Access Points
IWLAN Access Points with built-in
wireless interface; wireless networks
IEEE 802.11b/g/a/h at 2.4/5 GHz to
54 Mbps; national approvals;
WPA2/AES; Power over Ethernet
(PoE), degree of protection IP65
(-20°C to +60°C);
scope of delivery: 2 ANT795-4MR
antennas, IP 67 hybrid connector,
installation material, manual on
CD-ROM, English/German
SCALANCE W788-2RR
IWLAN Dual Access Point with two
built-in radio interfaces for establishment of radio connections with iPCF
• National approvals for
operation outside the U.S.1) 2)
• National approvals for
operation within the U.S. 2)
SCALANCE W788-1PRO
IWLAN Access Point with
one built-in wireless interface
• National approvals for
operation outside the U.S. 1)
• National approvals for
operation within the U.S.

Order No.
SCALANCE W-786 Access Points
for SIMATIC Mobile Panel 277(F)
IWLAN
IWLAN Access Points with
integrated wireless interfaces;
wireless networks;
IEEE 802.11b/g/a/h at 2.4/5 GHz
up to 54 Mbps. National approvals;
WPA2/AES; Power over Ethernet
(PoE), degree of protection IP65
(-40 °C to +70 °C); scope of
delivery: Mounting hardware,
48 V DC terminal block; manual
on CD-ROM; English/German
SCALANCE W-786-2RR
IWLAN Dual Access Point with two
integrated wireless interfaces for
setting up radio connections with
iPCF; RJ45 connection
Four internal antennas
• National approvals for
operation outside the U.S.1) 2)
• National approvals for
operation within the U.S. 2)

6GK5786-2BA60-6AB0

SCALANCE W-786-1PRO
IWLAN Access Points with built-in
wireless interface RJ45 connection
6GK5788-2AA60-6AA0
6GK5788-2AA60-6AB0

6GK5788-1AA60-2AA0
6GK5788-1AA60-2AB0

Two internal antennas
• National approvals for
operation outside the U.S. 1)
• National approvals for
operation within the U.S.

1)

RoW version: "Rest of World" version: Version for sale worldwide, apart
from in the USA.

2)

Already prepared for rapid roaming (iPCF-MC); iPCF-MC is already
included as of SCALANCE FW version V4.3.37.

Siemens ST 80 / ST PC · 2013

6GK5786-1BA60-2AA0
6GK5786-1BA60-2AB0

SCALANCE W-784 Access Points
IWLAN Access Points with built-in
wireless interfaces;wireless
networks IEEE 802.11b/g/a/h at
2.4/5 GHz to 54 Mbps. National
approvals; WPA2/AES; Power over
Ethernet (PoE), IP30 degree of
protection (-20 °C to +60 °C);
scope of supply: Installation
material, 24 V DC terminal block;
manual on CD-ROM
English/German
SCALANCE W784-1
IWLAN Access Points with
one built-in wireless interface
• National approvals for
operation outside the U.S. 1)
• National approvals for
operation within the U.S.

2/102

6GK5786-2BA60-6AA0

6GK5784-1AA30-2AA0
6GK5784-1AA30-2AB0

© Siemens AG 2013

Operator panels
Mobile Panel accessories
Additional accessories
Order No.

■ Dimensional drawings

Further IWLAN Access Point
versions

SCALANCE W-786 Access Points
IWLAN Access Points with
integrated wireless interfaces
(see Catalog IK PI); wireless
networks IEEE 802.11b/g/a/h at
2.4/5 GHz up to 54 Mbps. National
approvals; WPA2/AES; Power over
Ethernet (PoE), degree of protection IP65 (-40°C to +70°C); scope of
delivery: Installation material,
48 V DC terminal block; manual on
CD-ROM; English/German;

6GK5786-...
(see Catalog IK PI)

SCALANCE W-788 Access Points
IWLAN Access Points with
integrated wireless interfaces
(see Catalog IK PI); wireless
networks IEEE 802.11b/g/a/h at
2.4/5 GHz up to 54 Mbps. National
approvals; WPA2/AES; Power over
Ethernet (PoE), degree of protection IP65 (-20°C to +60°C); scope of
delivery: 2 ANT795-4MR antennas,
IP67 hybrid plug-in connector,
installation material, manual on
CD-ROM, English/German

6GK5788-...
(see Catalog IK PI)

PS791-2DC power supply
24 V DC power supply for installation in SCALANCE W-786 products;
operating instructions in English/
German

6GK5791-2DC00-0AA0

PS791-2AC power supply
110 V AC to 230 V AC power supply
for installation in SCALANCE W-786
products; operating instructions in
English/German

6GK5791-2AC00-0AA0

8°

8°
100.7

2

2

G_ST80_XX_00047

6GK5784-1AA30-...
(see Catalog IK PI)

18

24.6

SCALANCE W-784 Access Points
IWLAN Access Points with
integrated wireless interfaces
(see Catalog IK PI), wireless
networks IEEE 802.11b/g/a/h at
2.4/5 GHz up to 54 Mbps. National
approvals; WPA2/AES; Power over
Ethernet (PoE), degree of protection IP30 (-20 °C to +60 °C); scope
of delivery: Installation material,
24 V DC terminal block; manual on
CD-ROM; English/German;

225.2

■ Ordering data

SIMATIC Mobile Panel wall-mounting bracket

MOBY D accessories
MOBY D, MDS D100

6GT2600-0AD10

• 1 unit
Spacer

6GT2190-0AA00

• 1 unit
Fixing pocket

6GT2190-0AB00

• 1 unit

This catalog only includes accessories for current products.
The complete range of accessories can be found in the Mall:
https://eb.automation.siemens.com
or on our SIMATIC Support pages:
http://support.automation.siemens.com

Siemens ST 80 / ST PC · 2013

2/103

© Siemens AG 2013

Operator panels
SIMATIC HMI accessories
Connectors/converters/adapters

■ Overview
Components for the connection of SIMATIC HMI Panels
The range comprises connectors, adapters, converters, and
transducers.
An adapter can be used, for example, to mechanically rotate the
connector of a 9-pin panel plug by 90°. This may be beneficial
in confined spaces in the control desk or installation cabinet,
and is an easy way to provide additional flexibility.

2

Connectors/converters/adapters

A converter can be used to simulate a connection type that is
missing at the panel. In this way, for example, a TTY (20 mA) can
be generated from an RS422 signal, which is required for
connection to various types of PLC. Connectors are required for
power supply and I/O.
• 2-pin to n-pin connectors
• Converters
• Transducers
• Adapters for changing the cable outlet direction
• Bus connector
SIMATIC HMI accessories can also be used on non-Siemens
devices; see the technical specifications for more detailed information.
General SIMATIC HMI accessories are listed in this subsection;
the full range of SIMATIC HMI accessories is available in the Mall
and in our other online media.

2/104

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
SIMATIC HMI Accessories
HMI connecting components

■ Overview

2

RS 422 to RS 232 converter

Connector, female, 16-pin, I/O

RS 422 to TTY converter

Connector, female, 2x2-pin, jumpered internally

90 degree angle adapter, 1:1

Connector, female, 2-pin

For:
• Push Button Panels
• Key Panels
• Text Displays
• Operator Panels
• Touch Panels
• Multi Panels

•
•
•
•
•

Basic Panels
Comfort Panels
Mobile Panels
Thin Clients
Industrial USB Hub

Siemens ST 80 / ST PC · 2013

2/105

© Siemens AG 2013

Operator panels
SIMATIC HMI Accessories
HMI connecting components

■ Technical specifications

2

6AV6671-8XA00-0AX0

6ES7193-4JB00-0AA0

Connector, female, 2-pin

Connector, female, 2x2-pin

Installation type/mounting
Wall mounting/direct mounting possible

Yes; can be plugged into SIMATIC HMI device

Yes; can be plugged into SIMATIC HMI device

Supply voltage
Rated voltage/DC

24 V; DC

24 V; DC

Interfaces
Number of pins HMI-side

2; Female

2; Outgoing side jumpered internally, color-coded

Number of pins device-side

2; Female, screw terminals

4; Female, spring-loaded terminals, 0.75 mm2

Standards, approvals, certificates
CE

Yes

Yes

Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.

55 °C
0 °C

55 °C
0 °C

Storage/transport temperature
• Min.
• max.

-20 °C
70 °C

-20 °C
70 °C

Relative humidity
• max. relative humidity

95 %

95 %

Mechanics/material
Screw type
• 4.5 V

Yes

Type of housing (front)
• Plastic

Yes

Yes

Dimensions
Width

10 mm

10 mm

Height

15 mm

22 mm

Thickness

27 mm

25 mm

Scope of supply
Delivery unit in items

10

10

other
Note:

for SIMATIC HMI Panels, except for Key Panel

for ET 200S, interface module, KP32F, PN-to-PN coupler

6AV6671-3XY38-4AX0

6AV6671-3XY48-4AX0

6AV6671-3XY58-4AX0

Connector, female, 12-pin

Connector, female, 16-pin

Connector, female, 24-pin

Yes; can be plugged into
SIMATIC HMI device

Yes; can be plugged into
SIMATIC HMI device

Yes; can be plugged into
SIMATIC HMI device

Supply voltage
Rated voltage/DC

24 V; DC

24 V; DC

24 V; DC

Interfaces
Number of pins HMI-side

12; Female

16; Female

24; Female

Number of pins device-side

12; Female, spring-loaded terminals

16; Female, spring-loaded
terminals, 0.75 mm2

24; Female, spring-loaded
terminals, 0.75 mm2

Standards, approvals, certificates
CE

Yes

Yes

Yes

Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.

55 °C
0 °C

55 °C
0 °C

55 °C
0 °C

Storage/transport temperature
• Min.
• max.

-20 °C
70 °C

-20 °C
70 °C

-20 °C
70 °C

Relative humidity
• max. relative humidity

95 %

95 %

95 %

Mechanics/material
Type of housing (front)
• Plastic

Yes

Yes

Yes

Installation type/mounting
Wall mounting/direct mounting possible

2/106

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
SIMATIC HMI Accessories
HMI connecting components

■ Technical specifications (continued)
6AV6671-3XY38-4AX0

6AV6671-3XY48-4AX0

6AV6671-3XY58-4AX0

Connector, female, 12-pin

Connector, female, 16-pin

Connector, female, 24-pin

Dimensions
Width

16 mm

16 mm

16 mm

Height

20 mm

28 mm

54 mm

Thickness

20 mm

20 mm

20 mm

Scope of supply
Delivery unit in items

10; Without ejector

10; Without ejector

4; Without ejector

other
Note:

for KP8 PN

for KP8F PN, KP32F PN

for KP32F PN

6AV6671-8XE00-0AX0

6AV6671-8XJ00-0AX0

6AV6671-8XD00-0AX0

Converter, RS 422 to RS 232

Converter RS 422 to TTY

90 degree angle adapter, 1:1

Installation type/mounting
Wall mounting/direct mounting possible

Yes; Can be screwed onto the HMI

Yes; Can be screwed onto the HMI

Yes; Can be screwed onto the HMI

Interfaces
Number of pins HMI-side

9; Pin (RS422)

9; Pin (RS422)

9; Male

Number of pins device-side

9; Pin (RS232)

15; Socket (TTY)

9; Female

Standards, approvals, certificates
CE

Yes

Yes

Yes

Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.

55 °C
0 °C

55 °C
0 °C

55 °C
0 °C

Storage/transport temperature
• Min.
• max.

-20 °C
70 °C

-20 °C
70 °C

-20 °C
70 °C

Relative humidity
• max. relative humidity

95 %

95 %

95 %

Mechanics/material
Screw type
• 4.5 V

Yes; HMI page

Yes; HMI page

Yes; HMI page

Yes

Yes

Type of housing (front)
• Plastic
• Cast light alloy

2

Yes

Dimensions
Width

31 mm

42 mm

31 mm

Height

50 mm

62 mm

25 mm

Thickness

11 mm

11 mm

25 mm

Weight
Weight without packaging

26 g

28 g

34 g

Scope of supply
Delivery unit in items

1

1

1

suitable for all SIMATIC HMI RS422
interfaces, for details refer to the
operating instructions of the
respective device

suitable for all SIMATIC HMI RS422
interfaces, for details refer to the
operating instructions of the
respective device

suitable for all appropriate interfaces

other
Note:

Siemens ST 80 / ST PC · 2013

2/107

© Siemens AG 2013

Operator panels
SIMATIC HMI Accessories
HMI connecting components

■ Ordering data

Order No.

Connectors
24 V DC connector (2-pin)

2

Order No.
Converters

6AV6671-8XA00-0AX0

for all SIMATIC HMI Panels, without
screw mounting, loop-through not
possible.
Approved for all SIMATIC HMI
Panels except Key Panels.
24 V DC connector (2-pin)
(can be looped through)

6ES7193-4JB00-0AA0

6AV6671-3XY38-4AX0

6AV6671-8XJ00-0AX0

Adapters
90 degree angle adapter

6AV6671-3XY48-4AX0

16-pin, 24 V DC for
SIMATIC HMI Key Panel KP8F PN
and Key Panel KP32F PN
24-pin cable connector

RS422 to TTY converter
9-pin male contact (on HMI) to
15-pin female contact, to be
screwed onto HMI RS422 interface,
180 degree cable outlet,
for the connection to SIMATIC S5

12-pin, 24 V DC for
SIMATIC HMI Key Panel KP8 PN
16-pin cable connector

6AV6671-8XE00-0AX0

9-pin male contact (on HMI) to 9-pin
male contact, to be screwed onto
HMI RS422 interface, cable outlet
180 degrees, for connection of
non-Siemens PLC

for all SIMATIC HMI Panels, without
screw mounting, loop through possible, even if connecter unplugged.
Approved for Key Panels.
12-pin cable connector

RS422 to RS232 converter

6AV6671-8XD00-0AX0

9-pin male contact (on HMI) to 9-pin
female contact, 1:1 connection, to
be screwed onto the RS485/422/232
HMI interface, or any other suitable
interface

6AV6671-3XY58-4AX0

24-pin, 24 V DC for
SIMATIC HMI Key Panel KP32F PN

Note:
Delivery units/quantities are specified in the applicable technical
data.
This catalog only includes accessories for current products.
The complete range of accessories can be found in the Mall:
https://eb.automation.siemens.com
or on our SIMATIC Support pages:
http://support.automation.siemens.com

2/108

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
SIMATIC HMI Accessories
RS485 bus connector

■ Overview
• Used for connecting PROFIBUS nodes to the PROFIBUS bus
cable
• Easy installation
• FastConnect plugs ensure extremely short assembly times
due to their insulation-displacement technology
• Integrated terminating resistors (not in the case of
6ES7 972-0BA30-0XA0)
• Connectors with Sub-D socket permit PG connection without
the additional installation of network nodes

■ Ordering data
RS485 bus connector
with axial cable outlet (180°)

Order No.
6GK1500-0EA02

For industrial PC, SIMATIC HMI OP,
OLM; max. transmission rate
12 Mbit/s
SIPLUS DP PB RS485 connector
with axial cable outlet (180°)

6AG1500-0EA02-2AA0

RS485 bus connector
with cable outlet (90°)

6ES7972-0BA12-0XA0
6ES7972-0BB12-0XA0

SIPLUS DP PB RS485 connector
with 90° cable outlet
For extended temperature range
-25 … + 60 °C
• without PG interface
Based on 6ES7 972-0BA12-0XA0
• with PG interface
Based on 6ES7 972-0BB12-0XA0

6AG1972-0BA12-2XA0
6AG1972-0BB12-2XA0

6ES7972-0BA42-0XA0
6ES7972-0BB42-0XA0

SIPLUS DP PB RS485 connector
with inclined cable outlet (35°)
For extended temperature range
-25 … + 60 °C
• without PG interface
Based on 6ES7 942-0BA42-0XA0
• with PG interface
Based on 6ES7 942-0BB42-0XA0
RS485 bus connector
with cable outlet (30°)
With screw-terminals,
low-cost variant,
max. transmission rate 1.5 Mbit/s

With insulation displacement, max.
transmission rate 12 Mbps
Without PG interface
• 1 unit
• 100 units

6ES7972-0BA52-0XA0
6ES7972-0BA52-0XB0

With PG interface
• 1 unit
• 100 units

6ES7972-0BB52-0XA0
6ES7972-0BB52-0XB0

Without PG interface, grounding
via control cabinet cover
• 1 unit

6ES7972-0BA70-0XA0

With PG interface, grounding
via control cabinet cover
• 1 unit

6ES7972-0BB70-0XA0

PROFIBUS FastConnect RS485
bus connector with angled cable
outlet (35°)
With insulation displacement,
max. transmission rate 12 Mbps
• without PG interface
• with PG interface

RS485 bus connector
with angled cable outlet (35°)
With screw-terminals, max.
transmission rate 12 Mbit/s
• without PG interface
• with PG interface

PROFIBUS bus connector RS485
with FastConnect technology
PROFIBUS FastConnect bus connector RS485 with 90° cable outlet

For medial stress;
Based-on 6GK1 500-0EA02

With screw-terminals, max. transmission rate 12 Mbit/s
• without PG interface
• with PG interface

Order No.

6AG1972-0BA42-7XA0
6AG1972-0BB42-7XA0
6ES7972-0BA30-0XA0

PROFIBUS FastConnect
bus connector RS485 Plug 180

6ES7972-0BA60-0XA0
6ES7972-0BB60-0XA0
6GK1500-0FC10

With insulation displacement
terminals, with 180° cable outlet,
for industrial PC, SIMATIC HMI OP,
OLM; max. transmission rate
12 Mbit/s
SIMATIC S5/S7 plug-in cable for
PROFIBUS

6ES7901-4BD00-0XA0

Preassembled with two 9-pin sub-D
connectors; max. transmission rate
12 Mbit/s; 3 m
SIMATIC NET Manual Collection

6GK1975-1AA00-3AA0

Electronic manuals for communication systems, communication protocols, and communication products;
on DVD; German/English

Siemens ST 80 / ST PC · 2013

2/109

2

© Siemens AG 2013

Operator panels
SIMATIC HMI Accessories
IE FC RJ45 Plug 2 x 2

■ Overview
• Implementation of direct device connections over distances of
up to 100 m with Industrial Ethernet FC installation cable 2 x 2
without patching
• Easy connection (insulation displacement contacts) for 4-core
Twisted Pair installation cables (100 Mbit/s) without the need
for special tools
• Error-preventing connection technique thanks to visible
connection area as well as colored blade terminals
• Industry-compatible design (rugged metal housing, no easily
lost small parts)
• Excellent EMC shielding and deflection (metal housing)
• Integrated strain-relief for installation cables
• Compatible to the EN 50173 (RJ45) / ISO IEC 11801 standard
• Additional strain and bending relief of plug connector possible
through latching of plug on device housing, e.g. with
SCALANCE X, SCALANCE S, ET 200S.

2

■ Ordering data

Order No.

IE FC RJ45 plugs

Order No.
IE FC TP Standard Cable GP 2 x 2
(Type A)

RJ45 plug connector for Industrial
Ethernet with a rugged metal housing and integrated insulation displacement contacts for connecting
Industrial Ethernet FC installation
cables

4-core, shielded TP installation
cable for connection to
IE FC Outlet RJ45/ IE FC RJ45 Plug;
PROFINET-compatible;
with UL approval;

IE FC RJ45 Plug 180

Sold by the meter

180° cable outlet; for network
components and CPs/CPUs with
Industrial Ethernet interface
• 1 pack = 1 unit
• 1 pack = 10 units
• 1 pack = 50 units

max. length 1,000 m;
minimum order 20 m
6GK1901-1BB10-2AA0
6GK1901-1BB10-2AB0
6GK1901-1BB10-2AE0

IE FC RJ45 Plug 90
90° cable outlet; e.g. for ET 200S
• 1 pack = 1 unit
• 1 pack = 10 units
• 1 pack = 50 units

6GK1901-1BB20-2AA0
6GK1901-1BB20-2AB0
6GK1901-1BB20-2AE0

IE FC RJ45 Plug 145
145° cable outlet; e.g.
for SIMOTION and SINAMICS
• 1 pack = 1 unit
• 1 pack = 10 units
• 1 pack = 50 units

6GK1901-1BB30-0AA0
6GK1901-1BB30-0AB0
6GK1901-1BB30-0AE0

IE FC stripping tool

6GK1901-1GA00

Preadjusted stripping tool for fast
stripping of Industrial Ethernet FC
cables

2/110

Siemens ST 80 / ST PC · 2013

Preferred length
• 1000 m
IE FC TP Flexible Cable GP 2 x 2
(Type B)

6XV1840-2AH10

6XV1840-2AU10
6XV1870-2B

4-core, shielded TP installation
cable for connection to
IE FC Outlet RJ45/ IE FC RJ45 Plug
for occasional movement;
PROFINET-compatible;
with UL approval;
sold by the meter; max. length
1000 m, minimum order 20 m
IE FC TP Trailing Cable GP 2 x 2
(Type C)
4-core, shielded TP installation
cable for connection to
IE FC Outlet RJ45/ IE FC RJ45 Plug
for use in trailing cables;
PROFINET-compatible;
with UL approval;
sold by the meter; max. length
1000 m, minimum order 20 m

6XV1870-2D

© Siemens AG 2013

Operator panels
SIMATIC HMI Accessories
IE FC RJ45 Plug 2 x 2

■ Ordering data
IE FC TP Trailing Cable 2 x 2
(Type C)

Order No.
6XV1840-3AH10

4-core, shielded TP installation
cable for connection to
IE FC Outlet RJ45/
IE FC RJ45 Plug 180/90
for use in trailing cables;
PROFINET-compatible;
without UL approval;
sold by the meter;
max. length 1000 m,
minimum order 20 m
IE TP Torsion Cable GP 2 x 2
(Type C)

6XV1870-2F

6XV1840-4AH10

IE FC TP Food Cable GP 2 x 2
(Type C)

2
6XV1871-2L

4-core, shielded TP installation
cable for connection to
IE FC Outlet RJ45/
IE FC RJ45 Plug 180/90
for the food and beverages industry;
PROFINET-compliant;
sold by the meter;
max. length 1000 m,
minimum order 20 m
IE FC Blade Cassettes (5 mm)

6GK1901-1GB01

Replacement blade cassette for the
Industrial Ethernet stripping tool;
for use with IE FC RJ45 Plugs and
Modular Outlet,
5 items

4-core, shielded TP installation
cable for connection to
IE FC Outlet RJ45/ IE FC RJ45
Plug 180/90; marine approval;
sold by the meter;
max. length 1000 m,
minimum order 20 m
IE FC TP FRNC Cable GP 2 x 2
(Type B)

6XV1871-2S

4-core, shielded TP installation
cable for connection to
IE FC Outlet RJ45/
IE FC RJ45 Plug 180/90 for use in
festoon applications;
PROFINET-compatible;
with UL approval;
sold by the meter;
max. length 1000 m,
minimum order 20 m

4-core, shielded TP installation
cable for connection to
IE FC Outlet RJ45/ IE FC RJ45 Plug
for use with robots; PROFINETcompatible; with UL approval;
sold by the meter;
max. length 1000 m,
minimum order 20 m
IE FC TP Marine Cable 2 x 2
(Type B)

Order No.
IE FC TP Festoon Cable GP 2 x 2
(Type B)

6XV1871-2F

4-core, shielded, halogen-free TP
installation cable for connection to
IE FC Outlet RJ45/ IE FC RJ45 Plug
for occasional movement;
PROFINET-compatible;
with UL approval;
sold by the meter;
max. length 1000 m,
minimum order 20 m

Siemens ST 80 / ST PC · 2013

2/111

© Siemens AG 2013

Operator panels
SIMATIC HMI Accessories
Connecting cables

■ Overview

2

Example - connecting cables

Connecting cable PN (PROFINET) for Mobile Panels

Key
P = PROCESS COUPLING
K = optional process coupling (option required)
D = DOWNLOAD (update operating system, project, …)
U = booting (factory setting in the case of a missing or damaged
operating system)
MBP = Mobile Panel
You can find order numbers for the connecting cables required
to link SIMATIC Panels under ordering data.

Connecting cable DP (PROFIBUS) for Mobile Panels

2/112

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
SIMATIC HMI Accessories
Connecting cables

■ Overview (continued)
Overview of SIMATIC HMI connection options
RS 232 external
(15/9-pole)

TD-PPI
(incl. voltage)

RS 232
Null modem

RS 232/PPI
multi-master
cable

USB/PPI
multi-master
cable

MPI (PG-S7)
up to
187.5 kbaud

6XV1 440-2Kxxx

6ES7 9013EB10-0XA0

6ES7 9011BF00-0XA0

6ES7 9013CB30-0XA0

6ES7 9013DB30-0XA0

6ES7 9010BF00-0AA0

Key Panel KP8/KP8F, KP32F

-

-

-

-

-

-

PP7, PP17-I, PP17-II

-

-

-

-

-

-

KTP400 Basic mono PN

-

-

-

-

-

-

KTP600 Basic mono PN

-

-

-

-

-

-

KTP600 Basic color DP

-

-

-

D/U

D/U

P/D

KTP600 Basic color PN

-

-

-

-

-

-

KTP1000 Basic color DP

-

-

-

D/U

D/U

P/D

KTP1000 Basic color PN

-

-

-

-

-

-

KTP1500 Basic color PN

-

-

-

-

-

-

K(T)P400 Comfort

-

-

-

-

-

P/D

K(T)P700 - KP1500 Comfort

-

-

-

-

-

P/D

TP700 -TP2200 Comfort

-

-

-

-

-

P/D

MBP 177

-

-

-

D/U

-

-

MBP 277

-

-

-

D/U

-

-

TD200

-

P

-

D/U

-

P

TD400C

-

P

-

D/U

-

P

OP73micro

-

P

-

D/U

D/U

P

TP177micro

-

-

-

D/U

D/U

-

OP73

-

P

-

D/U

D/U

P/D

OP77A

-

-

-

D/U

D/U

P/D

OP77B

P

-

D/U

-

-

P/D

TP177A

-

-

-

D/U

D/U

P/D

TP177B

P 1)

-

-

D/U

-

P/D

TP177B 4"

P 1)

-

D

D

-

P/D

OP177B

P

1)

-

-

D/U

-

P/D

TP277-6

P 1)

-

-

D/U

-

P/D

OP277-6

P 1)

-

-

D/U

-

P/D

MP177-6 T

P 1)

-

-

D/U

-

P/D

MP277-8 T

P 1)

-

-

D/U

-

P/D

MP277-10 T

P 1)

-

-

D/U

-

P/D

MP377-12 T

P 1)

-

-

D

-

P/D

MP377-15 T

P 1)

-

-

D

-

P/D

MP377-19 T

P 1)

-

-

D

-

P/D

1)

2

Only in conjunction with the RS 422/232 converter

Siemens ST 80 / ST PC · 2013

2/113

© Siemens AG 2013

Operator panels
SIMATIC HMI Accessories
Connecting cables

■ Overview (continued)
DP PtP

6XV1 8300Axxx

2

DP
Standard

DP
(Mobile
Panel)

PN (cross
cable) 2)

PN
(standard
cable) 2)

PN
(Mobile
Panel)

RS 422 to
RS 232
converter

RS 232 to
TTY
converter
(20 mA)

90° angular
(9-pin 1:1)

Standard
PROFIBUS
(2-contact)

6XV1 4404Axxx

6XV1 8703RH20

Standard
Ethernet
CAT5

6XV1 4404Bxxx

6AV6 6718XE000AX0

6ES5 7341BD20

6AV6 6718XD000AX0

Point-topoint

Key Panel KP8/KP8F, KP32F

-

-

-

P/D

P/D

-

-

-

-

PP7, PP17-I, PP17-II

P

P

-

-

-

-

-

-

-

KTP400 Basic mono PN

-

-

-

P/D/U

P/D/U

-

-

-

-

KTP600 Basic mono PN

-

-

-

P/D/U

P/D/U

-

-

-

-

KTP600 Basic color DP

P/D

P/D

-

-

-

-

-

-

P/D/U

KTP600 Basic color PN

-

-

-

P/D/U

P/D/U

-

-

-

-

KTP1000 Basic color DP

P/D

P/D

-

-

-

-

-

-

P/D/U

KTP1000 Basic color PN

-

-

-

P/D/U

P/D/U

-

-

-

-

KTP1500 Basic color PN

-

-

-

P/D/U

P/D/U

-

-

-

-

K(T)P400 Comfort

P/D

P/D

-

P/D/U

P/D/U

-

-

-

P/D/U

K(T)P700 - TP1500 Comfort

P/D

P/D

-

P/D/U

P/D/U

-

-

-

P/D/U

TP700 -TP2200 Comfort

P/D

P/D

-

P/D/U

P/D/U

-

-

-

P/D/U

MBP 177 DP

P/D

P/D

P/D

-

-

-

-

-

-

MBP 177 PN

-

-

-

-

-

P/D

-

-

-

MBP 277

P/D

P/D

P/D

-

-

P/D

-

-

-

TD200

-

-

-

-

-

-

-

-

-

TD400C

-

-

-

-

-

-

-

-

-

OP73micro

P

-

-

-

-

-

-

-

-

TP177micro

P

P

-

-

-

-

-

-

P/D/U

OP73

P

P

-

-

-

-

-

-

-

OP77A

P

P

-

-

-

-

-

-

P/D/U

OP77B

P/D

P/D

-

-

-

-

-

P

P/D/U

TP177A

P

P

-

-

-

-

-

-

P/D/U

TP177B DP

P/D

P/D

-

-

-

-

P

P 4)

P/D/U

4)

P/D/U

TP177B PN/DP

P/D

P/D

-

P/D

P/D

-

P

P

TP177B 4"

P/D

P/D

-

P/D/U

P/D/U

-

P

P 4)

P/D/U

OP177B DP

P/D

P/D

-

-

-

-

P

P 4)

P/D/U

OP177B PN/DP

P/D

P/D

-

P/D

P/D

-

P

P 4)

P/D/U

TP277-6

P/D

P/D

-

P/D

P/D

-

P

P 4)

P/D/U

OP277-6

P/D

P/D

-

P/D

P/D

-

P

P 4)

P/D/U

MP177-6 T

P/D

P/D

-

P/D

P/D

-

P

P 4)

P/D/U

MP277-8 T

P/D

P/D

-

P/D

P/D

-

P

P 4)

P/D/U

MP277-8 K

P/D

P/D

-

P/D

P/D

-

P

P 4)

P/D/U

MP277-10 T

P/D

P/D

-

P/D

P/D

-

P

P 4)

P/D/U

MP277-10 K

P/D

P/D

-

P/D

P/D

-

P

P 4)

P/D/U

MP377-12 T

P/D

P/D

-

P/D/U

P/D/U

-

P

P 4)

P/D

MP377-12 K

P/D

P/D

-

P/D/U

P/D/U

-

P

P 4)

P/D

MP377-15 T

P/D

P/D

-

P/D/U

P/D/U

-

P

P 4)

P/D

MP377-19 T

P/D

P/D

-

P/D/U

P/D/U

-

P

P 4)

P/D

Note:
This table is for basic orientation only. Technical characteristics
are described in the communication manual or the respective
user manual:
1)

With gender changer

2)

PROFINET IRT (Isochronous Runtime); isochronous mode only possible
with IRT-enabled switch

3)

Only in conjunction with the RS422/RS232 converter
6AV6 671-8XE00-0AX0

4)

WinCC flexible 2008 SP2 and higher

2/114

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
SIMATIC HMI Accessories
Connecting cables

■ Ordering data

Order No.

Connecting cables
SIMATIC S7 connecting cables
MPI cable

6ES7901-0BF00-0AA0

Between SIMATIC S7 and
programming device via MPI max.
187.5 kBaud, standard length 5.0 m
Connecting cable

6ES7901-1BF00-0XA0

Between HMI adapter and PC/TS
Adapter (RS 232 cable/null-modem
cable) for OP 77B, TP 177A/B,
OP 177B, standard length 5.0 m
Connecting cables 6XV1440-2A 2)

6XV1440-2A…

Connecting cable between
TD/TP/OP and AG S5 95U to -155U,
1000 m max.
PROFIBUS connecting cable
830-1T
For connection of data terminals,
preassembled with two sub-D connectors, 9-pin terminated at both
ends
for PP, OP 73micro, OP 73,
TP 177micro, OP 77A/B, TP 177A,
TP/OP 177B
• 1.5 m
• 3.0 m

6XV1830-1CH15
6XV1830-1CH30

USB/PPI multi-master cable

6ES7901-3DB30-0XA0

Crossed TP cable 4 x 2, preassembled with 2 x RJ45 connectors
• 1.0 m
• 6.0 m
• 10.0 m

6XV1870-3RH10
6XV1870-3RH60
6XV1870-3RN10

2

DP connecting cable
(MPI/PROFIBUS)
For wired Mobile Panels 177,
Mobile Panels 277,
standard lengths
•2m
•5m
•8m
• 10 m
• 15 m
• 20 m
• 25 m 1)

6XV1440-4AH20
6XV1440-4AH50
6XV1440-4AH80
6XV1440-4AN10
6XV1440-4AN15
6XV1440-4AN20
6XV1440-4AN25

PN connecting cable (PROFINET)

For connecting the S7-200 to the
serial PC/OP interface
Standard length 5 m
PROFIBUS FC Standard Cable 2)

Order No.
Industrial Ethernet TP XP Cord
RJ45/RJ45

For wired Mobile Panels 177,
Mobile Panels 277, standard lengths
•2m
•5m
•8m
• 10 m
• 15 m
• 20 m
• 25 m 1)

6XV1440-4BH20
6XV1440-4BH50
6XV1440-4BH80
6XV1440-4BN10
6XV1440-4BN15
6XV1440-4BN20
6XV1440-4BN25

6XV1830-0E…

For connection to PPI;
standard type with special design
for quick mounting, 2-core,
shielded, sold by the meter,
max. delivery unit 1000 m,
minimum ordering quantity 20 m
1)

Instead of using longer cables, we recommend that you use additional
connection boxes, see length code in catalog appendix.

2)

See length code in catalog appendix.

Note:
Cable pin assignments can be found on the Internet in the online
help of WinCC flexible and under FAQs
http://support.automation.siemens.com
This catalog only includes accessories for current products. The
complete range of accessories can be found in the Mall:
https://eb.automation.siemens.com
or on our SIMATIC Support pages:
http://support.automation.siemens.com

Siemens ST 80 / ST PC · 2013

2/115

© Siemens AG 2013

Operator panels
SIMATIC HMI Accessories
Memory media

■ Overview
SIMATIC HMI memory media are suitable for industry and
optimized for the requirements in industrial environments.
Special formatting and write logarithms ensure fast read/write
cycles and a long service life of the memory cells.
• Push Button Panels
• Operator Panels
• Touch Panels
• Multi Panels
• Comfort Panels
• Mobile Panels
• Industrial USB Hub

2

Memory media

■ Technical specifications
6AV6671-1CB000AX2

6AV6671-8XB100AX1

6AV2181-8XP000AX0

6AV6574-2AC002AA1

6ES7 648-0DC500AA0

SIMATIC HMI
MM memory card,
128 MB

SIMATIC HMI
SD memory card,
512 MB

SIMATIC HMI
SD memory card,
2 GB

SIMATIC HMI
CF memory card,
512 MB

SIMATIC IPC USB
FLASH DRIVE,
bootable, 8GB

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Supply voltage
Type of supply voltage

DC

DC

DC

DC

DC

Rated voltage/DC

3.3 V

3.3 V

3.3 V

3.3 V

5.5 V

Input current
Current consumption
(rated value)

60 mA

60 mA

60 mA

75 mA

60 mA

Memory
Type of memory

Multi Media Card

Secure Digital
memory card

Secure Digital
memory card

CompactFlash
memory CF type I

USB flash drive

Size

128 Mbyte

512 Mbyte

2 048 Mbyte

512 Mbyte

8 192 Mbyte

Standards, approvals,
certificates
CE

Yes

Yes

Yes

Yes

Yes

Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.

50 °C
0 °C

50 °C
0 °C

50 °C
0 °C

50 °C
0 °C

55 °C
5 °C

Storage/transport temperature
• Min.
• max.

-20 °C
60 °C

-20 °C
60 °C

-20 °C
60 °C

-20 °C
60 °C

-40 °C
70 °C

Relative humidity
• max. relative humidity

90 %

90 %

90 %

90 %

85 %

Mechanics/material
Type of housing (front)
• Plastic

Yes

Yes

Yes

Yes

Yes

Installation type/mounting
Mounting in portrait format possible
Mounting in landscape format
possible

2/116

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
SIMATIC HMI Accessories
Memory media

■ Technical specifications (continued)
6AV6671-1CB000AX2

6AV6671-8XB100AX1

6AV2181-8XP000AX0

6AV6574-2AC002AA1

6ES7 648-0DC500AA0

SIMATIC HMI
MM memory card,
128 MB

SIMATIC HMI
SD memory card,
512 MB

SIMATIC HMI
SD memory card,
2 GB

SIMATIC HMI
CF memory card,
512 MB

SIMATIC IPC USB
FLASH DRIVE,
bootable, 8GB

Dimensions
Width

24 mm

24 mm

24 mm

42.8 mm

16.7 mm

Height

32 mm

32 mm

32 mm

36.4 mm

59.1 mm

Thickness

2.1 mm

2.1 mm

2.1 mm

3.3 mm

7 mm

Weight
Weight without packaging

3g

3g

3g

10 g

12 g

Scope of supply
Delivery unit in items

1

1

1

1

1

for OP 77B, TP177B,
OP 177B, TP 277,
OP 277, C7-635,
MP 177, MP 277,
MP 377,
Mobile Panel 177,
Mobile Panel 277,
Comfort Panel

for MP 177,
MP 277, MP 377 and
Mobile Panel 277,
WinCC flexible 2008
SP1 and higher for
OP 77, TP/OP 177,
TP/OP 277,
Mobile Panel 177,
with SD/MMC slot

For all
Comfort Panels

for SIMATIC HMI
Panels and IPCs with
CF slot

for SIMATIC HMI
devices with USB slot
and SIMATIC IPC,
with installed
SIMATIC IPC BIOS
Manager

other
Note:

■ Ordering data
SIMATIC HMI MM memory card
128 MB

Order No.
6AV6671-1CB00-0AX2

6AV6671-8XB10-0AX1

For contents and matching devices,
see Technical Data in the Mall
SIMATIC HMI SD memory card
2 GB

Note:
For delivery units/amounts, see the technical data for the
relevant product.

For contents and matching devices,
see Technical Data in the Mall
SIMATIC HMI SD memory card
512 MB

2

6AV2181-8XP00-0AX0

This catalog only includes accessories for current products.
The complete range of accessories can be found in the Mall:
https://eb.automation.siemens.com
or on our SIMATIC Support pages:
http://support.automation.siemens.com

For contents and matching devices,
see Technical Data in the Mall
SIMATIC HMI CF memory card
512 MB

6AV6574-2AC00-2AA1

For contents and matching devices,
see Technical Data in the Mall
PC card adapter
for CF memory card

6AV6574-2AF00-8AX0

For contents and matching devices,
see Technical Data in the Mall
PC memory card, 512 MB

6AV6574-2AC00-2AF1

For contents and matching devices,
see Technical Data in the Mall
SIMATIC IPC USB flash drive 8 GB

6ES7648-0DC50-0AA0

For contents and matching devices,
see Technical Data in the Mall
SIMATIC memory module for
Push Button Panel

6ED1056-1BA00-0AA0

For contents and matching devices,
see Technical Data in the Mall

Siemens ST 80 / ST PC · 2013

2/117

© Siemens AG 2013

Operator panels
SIMATIC HMI Accessories
Service sets

■ Overview
Service sets are available for the product groups listed below:
• Push Button Panels
• Key Panels
• Operator Panels
• Touch Panels
• Multi Panels
• Basic Panels
• Comfort Panels
• Mobile Panels
• Industrial USB Hub

2

■ Technical specifications
6AV6671-2EA000AX0

6AV6675-3AA000AX0

6AV6671-4CA000AX0

6AV6574-1AA044AA0

6AV6671-5CA000AX2

6AV6671-3EA010AX0

Service set 4"
and 6" devices

Service set 10"
devices, Type 2

Service set 15"
devices

Service set
Mobile Panel

Service set
Mobile Panel
277(F)
IWLAN V2

Service set
Industrial USB
Hub 4

Battery
Design
• Special design

Yes;
Spare 3.6 V
1.5 Ah backup
battery included
in the package

Standards, approvals, certificates
CE

Yes

Yes

Yes

Yes

Yes

Yes

Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.

55 °C
0 °C

55 °C
0 °C

55 °C
0 °C

55 °C
0 °C

55 °C
0 °C

55 °C
0 °C

Storage/transport temperature
• Min.
• max.

-20 °C
70 °C

-20 °C
70 °C

-20 °C
70 °C

-20 °C
70 °C

-20 °C
70 °C

-20 °C
70 °C

Relative humidity
• max. relative humidity

95 %

95 %

95 %

95 %

95 %

95 %

2/118

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
SIMATIC HMI Accessories
Service sets

■ Technical specifications (continued)
6AV6671-2EA000AX0

6AV6675-3AA000AX0

6AV6671-4CA000AX0

6AV6574-1AA044AA0

6AV6671-5CA000AX2

6AV6671-3EA010AX0

Service set 4"
and 6" devices

Service set 10"
devices, Type 2

Service set 15"
devices

Service set
Mobile Panel

Service set
Mobile Panel
277(F)
IWLAN V2

Service set
Industrial USB
Hub 4

1; Content: 2 x
seal KTP 400-TP
177B 4", 2 x seal
for KTP 600, 7 x
aluminum mounting clip, 1 x 2-pin
female connector

1; Content:
1 x mounting
seal, 10 x cast
aluminum mounting clip, 1 x 2-pin
female connector

1; Content:
1 x mounting
seal, 1 x memory
card lock,
12 x cast aluminum mounting
clip, 1 x 2-pin
female connector,
1 x Allen key

1; Content:
1 x blanking plug,
2 x PG cable
gland A-Box,
2 x 12-pole terminal box,
1 x 3-pole terminal box,
1 x blanking
cover A-Box,
2 x corner seal l/r
and O-ring, 4 x
decorative film for
corner seal l/r

1; Content:
2 x charging station cover l/r,
1 x charging station connector,
2 x corner seal l/r,
2 x gasket corner seal, 4 x
decorative film
corner seal l/r,
1 x battery incl.
cover, 1 x spare
key

1; Content:
1 x mounting
seal, 1 x mounting frame, 5 x
plastic mounting
clip, 1 x 2-pin
female connector

for KTP 400
for MP 277 10"
Basic, KTP 600
Touch with stainBasic, TP 177B 4" less steel front

for MP 377 15"
Touch with stainless steel front

for Mobile Panel
170, Mobile Panel
177

for Mobile Panel
277 IWLAN V2,
Mobile Panel
277F IWLAN V2

For the Industrial
USB Hub 4

6AV3678-3XC30

6AV3678-1CC10

6AV6671-1XA000AX0

6AV6574-1AA004AX0

6AV2181-8XA800AX0

6AV6671-2XA000AX0

Service set
Push Button
Panel

Service set
TD17, OP7/17

Service set
OP73micro,
OP73, OP77

Service set 6"
devices, Type 1

Service set 6"
devices, Type 2

Service set 6"
devices, Type 3

Standards, approvals, certificates
CE

Yes

Yes

Yes

Yes

Yes

Yes

Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.

55 °C
0 °C

55 °C
0 °C

55 °C
0 °C

55 °C
0 °C

55 °C
0 °C

55 °C
0 °C

Storage/transport temperature
• Min.
• max.

-20 °C
70 °C

-20 °C
70 °C

-20 °C
70 °C

-20 °C
70 °C

-20 °C
70 °C

-20 °C
70 °C

Relative humidity
• max. relative humidity

95 %

95 %

95 %

95 %

95 %

95 %

1; Content:
1 x mounting seal
PP7, 1 x mounting seal PP17, 5
x plastic mounting clip, 1 x 2-pin
female connector,
1 x 3-pin female
connector, 1 x
4-pin female connector, 2 x 16-pin
female connector

1; Content:
1 x mounting seal
TD17, 1 x mounting seal OP7,
1 x mounting seal
TD/OP17,
5 x plastic
mounting clip

1; Content:
1 x mounting seal
OP73, 1 x mounting seal OP77,
4 x plastic mounting clip, 1 x 2-pin
female connector

1; Content:
3 x mounting
seal, 2 x labeling
strip, 7 x plastic
mounting clip,
1 x 2-pin female
connector

1; Content:
3 x mounting
seal, 2 x labeling
strip, 7 x plastic
mounting clip,
20 x aluminum
mounting clip,
1 x 2-pin female
connector

1; Content:
1 x mounting seal
TP 177, 1 x
mounting seal
OP 177, 7 x plastic mounting clip,
1 x 2-pin female
connector

for PP7, PP17-I,
PP17-II

for TD17, OP7,
OP17

for OP73micro,
OP73, OP77A,
OP77B

for TP 070, TP
170A/B, OP
170B, TP
170micro, OP
270 6", TP 270 6",
MP 270B 6"
Touch

for TP 070, TP
170A/B, OP
170B, TP
170micro, OP /TP
270 6", MP 177
6"T, MP 270B 6"
Touch

for TP 177micro,
TP 177A, TP
177B, OP 177B

Scope of supply
Number of sets

other
Note:

Scope of supply
Number of sets

other
Note:

Siemens ST 80 / ST PC · 2013

2/119

2

© Siemens AG 2013

Operator panels
SIMATIC HMI Accessories
Service sets

■ Technical specifications (continued)

2

6AV65741AA00-2CX0

6AV65741AA00-2DX0

6AV66713XA01-0AX0

6AV66713XA01-0AX1

6AV65741AA00-2BX0

6AV66714XA00-0AX0

6AV66715CA00-0AX1

Service set
10" to 15"
devices

Service set
10" devices,
Type 1

Service set
6" to 10"
devices

Service set
8" to 10"
devices

Service set
12" devices

Service set
12" to 19"
devices

Service set
Mobile Panel
277 (F)
IWLAN V1

Battery
Design
• Special design

Yes; Spare
battery
included in the
package

Standards, approvals, certificates
CE

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.

55 °C
0 °C

55 °C
0 °C

55 °C
0 °C

55 °C
0 °C

55 °C
0 °C

55 °C
0 °C

55 °C
0 °C

Storage/transport temperature
• Min.
• max.

-20 °C
70 °C

-20 °C
70 °C

-20 °C
70 °C

-20 °C
70 °C

-20 °C
70 °C

-20 °C
70 °C

-20 °C
70 °C

Relative humidity
• max. relative humidity

95 %

95 %

95 %

95 %

95 %

95 %

95 %

1; Content:
2 x mounting
seal,
7 x mounting
clip, 1 x 2-pin
female connector,
1 x CF card
lock, 1 x
PC card lock

1; Content:
1 x slide-in
labels OP 270
10" and MP
270 10" Key,
1 x mounting
seal OP 270
10" and MP
270 10" Key,
10 x cast aluminum mounting clip, 1 x
2-pin female
connector

1; Content:
6 x devicespecific seal,
15 x aluminum mounting
clip, 1 x 2-pin
female connector

1; Content:
14 x spring
mounting clip,
1 x connector,
female, 2-pin

1; Content:
2 x labeling
strip, 6 x aluminum mounting clip, 1 x
2-pin female
connector,
2 x memory
card lock

1; Content:
1 x mounting
seal MP 377
12" Key, 1 x
mounting seal
MP 377 12"
Touch, 1 x
mounting seal
MP 377 15"
Touch, 1 x
mounting seal
MP 377 19"
Touch, 18 x
aluminum
mounting clip,
1 x 2-pin
female connector

1; Content:
2 x charging
station cover
l/r, 1 x charging station
connector, 2 x
corner seal l/r,
2 x gasket corner seal, 4 x
decorative film
corner seal l/r,
1 x battery
incl. cover, 1 x
spare key

for C7-636
Touch, TP270
10", MP270B
10" Touch,
MP370 12"
Touch, MP370
15" Touch

for OP 270 10",
MP 270B Key

for TP/OP 277
6", MP 277 8"
Touch, MP 277
8" Key, MP 277
10" Key product version "ES
14" and later,
MP 277 10"
Touch product
version "ES 14"
and later

for MP 277 8"
Touch, MP 277
8" Key product version "ES
15" and later,
MP 277 10"
Touch product
version "ES 15"
and later

for MP 370 12"
Key

for MP 377 12"
Key, MP 377
12" Touch,
MP 377 15"
Touch, MP 377
19" Touch

for Mobile
Panel 277
IWLAN, Mobile
Panel 277F
IWLAN

Scope of supply
Number of sets

other
Note:

2/120

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
SIMATIC HMI Accessories
Service sets

■ Ordering data
Service set for 4" and 6" devices

Order No.
6AV6671-2EA00-0AX0

For contents and matching devices,
see Technical Data
Service set for 10" devices, Type 2

6AV6675-3AA00-0AX0

6AV6671-4CA00-0AX0

6AV6574-1AA04-4AA0

6AV6671-5CA00-0AX2

For contents and matching devices,
see Technical Data in the Mall

Service set for 10", Type 1

6AV6574-1AA00-2CX0

6AV6574-1AA00-2DX0

6AV6574-1AA00-2BX0

For contents and matching devices,
see Technical Data in the Mall
Service set for 12" to 19" devices

6AV6671-1XA00-0AX0

6AV6671-3XA01-0AX1

For contents and matching devices,
see Technical Data in the Mall
Service set for 12" devices

6AV3678-1CC10

6AV6671-3XA01-0AX0

For contents and matching devices,
see Technical Data in the Mall
Service set for 8" to 10" devices

6AV3678-3XC30

For contents and matching devices,
see Technical Data in the Mall
Service set for OP73 micro, OP73,
OP77

Service set for 10" to 15" devices

Service set for 6" to 10" devices
6AV6671-3EA01-0AX0

For contents and matching devices,
see Technical Data in the Mall
Service set for TD17, OP7/17

2

6AV6671-2XA00-0AX0

For contents and matching devices,
see Technical Data in the Mall

For contents and matching devices,
see Technical Data
Service set for pushbutton panel

Service set for 6" devices, Type 3

For contents and matching devices,
see Technical Data in the Mall

For contents and matching devices,
see Technical Data
Service Kit Industrial USB Hub 4

6AV2181-8XA80-0AX0

For contents and matching devices,
see Technical Data in the Mall

For contents and matching devices,
see Technical Data
Service set for Mobile Panel
277(F) IWLAN

Service set for 6" devices, Type 2
For contents and matching devices,
see Technical Data in the Mall

For contents and matching devices,
see Technical Data
Service set for Mobile Panel

6AV6574-1AA00-4AX0

For contents and matching devices,
see Technical Data in the Mall

For contents and matching devices,
see Technical Data
Service set for 15" devices

Order No.
Service set for 6" devices, Type 1

6AV6671-4XA00-0AX0

For contents and matching devices,
see Technical Data in the Mall
Service set for Mobile Panel
277(F) IWLAN V1

6AV6671-5CA00-0AX1

For contents and matching devices,
see Technical Data in the Mall

Note:
This catalog only includes accessories for current products.
The complete range of accessories can be found in the Mall:
https://eb.automation.siemens.com
or on our SIMATIC Support pages:
http://support.automation.siemens.com

Siemens ST 80 / ST PC · 2013

2/121

© Siemens AG 2013

Operator panels
SIMATIC HMI Accessories
Protective covers

■ Overview
Protective covers with IP65 degree of protection provide
complete frontal protection of the panel against dirt and
scratches; the protective covers can be kept clean using highpressure cleaning equipment. Ready-made templates can be
downloaded to help you create and print out your own low-cost
frame designs between panel and protective cover.

2

Adhesive protective membranes are available for simple display
protection.
Protective covers are available for the following
SIMATIC HMI Panels:
• Touch Panels
• Operator Panels
• Multi Panels

■ Technical specifications
6AV6574-1AE004AX0

6AV6671-1AJ000AX0

6AV6671-2DJ000AX0

6AV6671-3CK010AX0

6AV6671-3CK000AX0

Protective cover 6"
Touch devices

Protective cover
OP77

Protective cover
OP177

Protective cover
MP 277 8" Touch

Protective cover
MP 277 10" Touch

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Degree and class of protection
IP (at the front)

IP65

IP65

IP65

IP65

IP65

Standards, approvals, certificates
CE

Yes

Yes

Yes

Yes

Yes

Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.

50 °C
0 °C

50 °C
0 °C

50 °C
0 °C

50 °C
0 °C

50 °C
0 °C

Storage/transport temperature
• Min.
• max.

-20 °C
60 °C

-20 °C
60 °C

-20 °C
60 °C

-20 °C
60 °C

-20 °C
60 °C

Relative humidity
• max. relative humidity

95 %

95 %

95 %

95 %

95 %

Mechanics/material
Plastic

Yes

Yes

Yes

Yes

Yes

Dimensions
Width

242.3 mm

178.6 mm

274.3 mm

270.8 mm

355.8 mm

Height

186.3 mm

214.6 mm

243.26 mm

211 mm

294 mm

Thickness

10 mm

7.8 mm

7.8 mm

7.8 mm

7.8 mm

Height of housing front
• Mounting cutout, width
• Mounting cutout, height

198 mm
142 mm

135 mm
171 mm

229 mm
196 mm

226 mm
166 mm

310 mm
248 mm

Weight
Weight without packaging

750 g

750 g

750 g

750 g

750 g

Installation type/mounting
Mounting in portrait format possible
Mounting in landscape format
possible

2/122

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
SIMATIC HMI Accessories
Protective covers

■ Technical specifications (continued)

Scope of supply
Number of sets

other
Note:

■ Ordering data
Protective covers
for 6" Touch devices

6AV6574-1AE004AX0

6AV6671-1AJ000AX0

6AV6671-2DJ000AX0

6AV6671-3CK010AX0

6AV6671-3CK000AX0

Protective cover 6"
Touch devices

Protective cover
OP77

Protective cover
OP177

Protective cover
MP 277 8" Touch

Protective cover
MP 277 10" Touch

2; 2 cover frames,
2 base frames,
2 protective covers,
molded (for TP 070,
TP 170micro,
TP 170A/B), 2 protective covers, smooth
(for TP 177micro,
TP 177A/B, TP 270 6",
MP 177 6" Touch,
MP 270 6" Touch)

2; 2 cover frames,
2 base frames,
2 protective covers

2; 2 cover frames,
2 base frames,
2 protective covers

2; 2 cover frames,
2 base frames,
2 protective covers

2; 2 cover frames,
2 base frames,
2 protective covers

for TP 070,
TP 170A, TP 170B,
TP 170micro,
TP 177micro,
TP 177A, TP 177B,
TP 270 6 ", TP 277 6 ",
MP 270 6" Touch

for OP 77A, OP 77B

For OP177B

for MP 277 8" Touch
as far as product
version "ES 14" with
narrow frame

for MP 277 10" Touch
up to product version
"ES 14 ", Thin Client
10" up to "ES 03"
(6AV6646-0AA212AX0) with narrow
frame

Order No.
6AV6574-1AE00-4AX0

This catalog only includes accessories for current products.

For TP 070, TP 170micro,
TP 177micro, TP 170A/B,
TP 177A/B, TP 270 6", TP 277 6",
MP 177 6" Touch, MP 270 6" Touch
consisting of: see technical data
Protective covers for OP 77

Note:
The complete range of accessories can be found in the Mall:
https://eb.automation.siemens.com

6AV6671-1AJ00-0AX0

or on our SIMATIC Support pages:
http://support.automation.siemens.com

For OP77 and OP77B
consisting of: see technical data
Protective covers for OP 177

6AV6671-2DJ00-0AX0

For OP177B
consisting of: see technical data
Protective covers for MP 277 8"
Touch devices

6AV6671-3CK01-0AX0

Only suitable for MP 277 8" Touch
up to E14 1) (for devices with a
narrow frame geometry)
consisting of: see technical data
Protective covers for MP 277 10"
Touch devices

6AV6671-3CK00-0AX0

Only suitable for
MP 277 10" Touch up to E14 1)
and 10" Thin Client up to E03 2)
(for devices with a narrow frame
geometry)
consisting of: see technical data
1)

E14 = Product version 14

2)

E03 = Product version 03

Siemens ST 80 / ST PC · 2013

2/123

2

© Siemens AG 2013

Operator panels
SIMATIC HMI Accessories
Protective films

■ Overview
Protective films for:
• Touch Panels
• C7 devices
• Multi Panels
• Thin Clients
• Touch Panels
• Basic Panels
• Comfort Panels
• Mobile Panels

2

Protective films protect the display from dirt and scratching
during operation and use.
For complete protection of the front side in harsh environments,
protective covers are available for some devices.
Note:
During installation, the protective films must completely cover
the display. For compatibility reasons, not all protective films
extend as far as the edge of the enclosure. This does not,
however, affect the protective function.

2/124

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
SIMATIC HMI Accessories
Protective films

■ Technical specifications
6AV6671-2EC000AX0

6AV6671-2XC000AX0

6AV6574-1AD044AA0

6AV6671-5BC000AX0

6AV6645-7AB150AS0

6AV6671-3DC000AX0

Protective film
4" Touch
devices

Protective film
6" Touch
devices, Type 3

Protective film
6" Touch
devices,
Type 10

Protective film
8" Touch
devices,
Type 10

Protective film
10" Touch
devices,
Type 10

Protective film
10" Thin Client
and MP277 up to
ES14

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Standards, approvals, certificates
CE

Yes

Yes

Yes

Yes

Yes

Yes

Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.

50 °C
0 °C

50 °C
0 °C

50 °C
0 °C

50 °C
0 °C

50 °C
0 °C

50 °C
0 °C

Storage/transport temperature
• Min.
• max.

-20 °C
60 °C

-20 °C
60 °C

-20 °C
60 °C

-20 °C
60 °C

-20 °C
60 °C

-20 °C
60 °C

Relative humidity
• max. relative humidity

90 %

90 %

90 %

90 %

90 %

90 %

Films
printable with laser printer

Yes

Yes

Yes

Yes

Yes

Yes

Yes;
Nonreflecting

Yes;
Nonreflecting

Yes;
Nonreflecting

Yes;
Nonreflecting

Yes; Nonreflecting

Yes;
Nonreflecting

Dimensions
Width

120 mm

179.4 mm

120.5 mm

155.5 mm

223.17 mm

292 mm

Height

105 mm

141.4 mm

91 mm

124.9 mm

170.37 mm

248 mm

Thickness

0.125 mm

0.125 mm

0.125 mm

0.3 mm

0.3 mm

0.125 mm

Scope of supply
Delivery unit in items

10

10

10

2

10

10

for TP 177B 4",
KTP 400 Basic

for TP 177micro,
TP 177A,
TP 177B,
OP 177B,
KTP 600 Basic

for
Mobile Panel 170,
Mobile Panel 177

for
Mobile Panel 277
8"

for
Mobile Panel 277
10"

Installation type/mounting
Mounting in portrait format possible
Mounting in landscape format possible

Mechanics/material
Plastic

other
Note:

Siemens ST 80 / ST PC · 2013

2

2/125

© Siemens AG 2013

Operator panels
SIMATIC HMI Accessories
Protective films

■ Technical specifications (continued)

2

6AV6671-3DC000AX5

6AV6574-1AD004EX0

6AV2124-6DJ000AX0

6AV2124-6GJ000AX0

6AV2124-6JJ000AX0

6AV2124-6MJ000AX0

Protective film
10" Key Panel,
Thin Client and
MP277 as of
ES15

Protective film
15" TP1500,
MP370/377 and
ThinClient

Protective film
4" widescreen

Protective film
7" widescreen

Protective film
9" widescreen

Protective film
12" widescreen

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Standards, approvals, certificates
CE

Yes

Yes

Yes

Yes

Yes

Yes

Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.

50 °C
0 °C

50 °C
0 °C

50 °C
0 °C

50 °C
0 °C

50 °C
0 °C

50 °C
0 °C

Storage/transport temperature
• Min.
• max.

-20 °C
60 °C

-20 °C
60 °C

-20 °C
60 °C

-20 °C
60 °C

-20 °C
60 °C

-20 °C
60 °C

Relative humidity
• max. relative humidity

90 %

90 %

90 %

90 %

90 %

90 %

Films
printable with laser printer

Yes

Yes

Yes

Yes

Yes

Yes

Yes;
Nonreflecting

Yes;
Nonreflecting

Yes;
Nonreflecting

Yes;
Nonreflecting

Yes;
Nonreflecting

Yes;
Nonreflecting

Dimensions
Width

299.8 mm

362 mm

131.4 mm

205.4 mm

265.4 mm

321.4 mm

Height

259.9 mm

289 mm

107.4 mm

149.4 mm

181.4 mm

232.4 mm

Thickness

0.125 mm

0.125 mm

0.125 mm

0.125 mm

0.125 mm

0.125 mm

Scope of supply
Delivery unit in items

10

10

10

10

10

10

for KTP400
Comfort, KTP400
Basic color PN

for TP700
Comfort,
IPC277D

for TP900
Comfort,
IPC277D

for TP1200
Comfort,
IPC277D

Installation type/mounting
Mounting in portrait format possible
Mounting in landscape format
possible

Mechanics/material
Plastic

other
Note:

2/126

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
SIMATIC HMI Accessories
Protective films

■ Technical specifications (continued)
6AV2124-6QJ00-0AX1

6AV2124-6UJ00-0AX1

6AV2124-6XJ00-0AX1

Protective film 15" widescreen

Protective film 19" widescreen

Protective film 22" widescreen

Yes

Yes

Yes

Yes

Yes

Yes

Standards, approvals, certificates
CE

Yes

Yes

Yes

Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.

50 °C
0 °C

50 °C
0 °C

50 °C
0 °C

Storage/transport temperature
• Min.
• max.

-20 °C
60 °C

-20 °C
60 °C

-20 °C
60 °C

Relative humidity
• max. relative humidity

90 %

90 %

90 %

Films
printable with laser printer

Yes

Yes

Yes

Mechanics/material
Plastic

Yes; Nonreflecting

Yes; Nonreflecting

Yes; Nonreflecting

Dimensions
Width

368 mm

451 mm

518 mm

Height

231 mm

285 mm

334 mm

Thickness

0.125 mm

0.125 mm

0.125 mm

Weight
Weight without packaging

26 g; Per unit

34 g; Per unit

44 g; Per unit

Scope of supply
Delivery unit in items

10

10

10

for Comfort Panel, IPC, Flat Panel,
Thin Client

for Comfort Panel, IPC, Flat Panel,
Thin Client

for Comfort Panel, IPC, Flat Panel,
Thin Client

Installation type/mounting
Mounting in portrait format possible
Mounting in landscape format
possible

other
Note:

Siemens ST 80 / ST PC · 2013

2

2/127

© Siemens AG 2013

Operator panels
SIMATIC HMI Accessories
Protective films

■ Technical specifications (continued)

2

6AV6574-1AD004DX0

6AV6574-1AD004CX0

6AV6671-2XC000AX0

6AV6671-3CC000AX0

6AV6671-3CC000AX5

6AV7672-1CE000AA0

Protective film
6" Touch
devices, Type 2

Protective film
10" - 12" TP/MP
270/370/377 and
C7-636

Protective film
6" Touch
devices, Type 3

Protective film
8" Touch
devices, Type 1

Protective film
8" Touch
devices, Type 2

Protective film
19" MP377,
panel PC and
Flat Panel

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Standards, approvals, certificates
CE

Yes

Yes

Yes

Yes

Yes

Yes

Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.

50 °C
0 °C

50 °C
0 °C

50 °C
0 °C

50 °C
0 °C

50 °C
0 °C

50 °C
0 °C

Storage/transport temperature
• Min.
• max.

-20 °C
60 °C

-20 °C
60 °C

-20 °C
60 °C

-20 °C
60 °C

-20 °C
60 °C

-20 °C
60 °C

Relative humidity
• max. relative humidity

90 %

90 %

90 %

90 %

90 %

90 %

Films
printable with laser printer

Yes

Yes

Yes

Yes

Yes

Yes

Yes;
Nonreflecting

Yes;
Nonreflecting

Yes;
Nonreflecting

Yes;
Nonreflecting

Yes;
Nonreflecting

Yes;
Nonreflecting

Dimensions
Width

178.4 mm

297.4 mm

179.4 mm

207 mm

217 mm

378 mm

Height

135.4 mm

254.4 mm

141.4 mm

165 mm

217 mm

302.5 mm

Thickness

0.125 mm

0.125 mm

0.125 mm

0.125 mm

0.125 mm

0.2 mm

Scope of supply
Delivery unit in items

10

10

10

10

10

10

for TP 177micro,
TP 177A,
TP 177B,
OP 177B,
KTP 600 Basic

for MP 277 8"
Touch up to
product version
"ES 14"

for MP 277 8"
Touch in product
version "ES 15"
and later

Installation type/mounting
Mounting in portrait format possible
Mounting in landscape format
possible

Mechanics/material
Plastic

other
Note:

2/128

for TP 270 6",
TP 277 6",
MP 177 6" Touch,
MP 270B 6"
Touch

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
SIMATIC HMI Accessories
Protective films

■ Ordering data
Protective films for 4" Touch
devices

Order No.
Protective films for 6" Touch
devices, type 1
For contents and matching devices,
see Technical Data and Mall

6AV6574-1AD00-4AX0

6AV6671-2XC00-0AX0

Protective films for 6" Touch
devices, type 4
For contents and matching devices,
see Technical Data and Mall

6AV3672-2CS00

Protective films for 10" Touch
devices, type 3

6AV3672-2CS11

For contents and matching devices,
see Technical Data and Mall
Protective films for 6" Touch
devices, type 4
For contents and matching devices,
see Technical Data and Mall
Protective films for 6" Touch
devices, type 10

6AV6574-1AD04-4AA0

6AV6671-5BC00-0AX0

6AV6645-7AB15-0AS0

6AV6671-3DC00-0AX0

6AV6671-3DC00-0AX5

6AV6574-1AD00-4EX0

6AV2124-6DJ00-0AX0

For contents and matching devices,
see Technical Data and Mall
Protective films 7" widescreen

Protective films for 6" Touch
devices, type 3

6AV6671-2XC00-0AX0

Protective films for 8" Touch
devices, type 1

6AV6671-3CC00-0AX0

Protective films for 8" Touch
devices, type 2

6AV6671-3CC00-0AX5

For contents and matching devices,
see Technical Data and Mall

For contents and matching devices,
see Technical Data and Mall
Protective films 4" widescreen

6AV6574-1AD00-4CX0

For contents and matching devices,
see Technical Data and Mall

For contents and matching devices,
see Technical Data and Mall
Protective films for 15" Touch
devices

Protective films for 10" to 12"
Touch devices

For contents and matching devices,
see Technical Data and Mall

For contents and matching devices,
see Technical Data and Mall
Protective films for 10" Touch
devices, type 2

6AV6574-1AD00-4DX0

For contents and matching devices,
see Technical Data and Mall

For contents and matching devices,
see Technical Data and Mall
Protective films for 10" Touch
devices, type 1

Protective films for 10" Touch
devices, type 2
For contents and matching devices,
see Technical Data and Mall

For contents and matching devices,
see Technical Data and Mall
Protective films for 10" Touch
devices, type 10

2

For contents and matching devices,
see Technical Data and Mall

For contents and matching devices,
see Technical Data and Mall
Protective films for 8" Touch
devices, type 10

Order No.

6AV6671-2EC00-0AX0

Protective films for 19" Touch
devices

6AV7672-1CE00-0AA0

For contents and matching devices,
see Technical Data and Mall
6AV2124-6GJ00-0AX0

For contents and matching devices,
see Technical Data and Mall
Protective films 9" widescreen

6AV2124-6JJ00-0AX0

For contents and matching devices,
see Technical Data and Mall
Protective films 12" widescreen

6AV2124-6MJ00-0AX0

For contents and matching devices,
see Technical Data and Mall
Protective films 15" widescreen

6AV2124-6QJ00-0AX1

For contents and matching devices,
see Technical Data and Mall
Protective films 19" widescreen

6AV2124-6UJ00-0AX1

For contents and matching devices,
see Technical Data and Mall
Protective films 22" widescreen

6AV2124-6XJ00-0AX1

For contents and matching devices,
see Technical Data and Mall

Note:
This catalog only includes accessories for current products. The
complete range of accessories can be found in the Mall:
https://eb.automation.siemens.com
or on our SIMATIC Support pages:
http://support.automation.siemens.com

Siemens ST 80 / ST PC · 2013

2/129

© Siemens AG 2013

Operator panels
SIMATIC HMI Accessories
Fasteners

■ Overview
All parts required to install a SIMATIC HMI Panel are listed here.
Mounting frames enable compliance with device-specific
degrees of protection IP65, NEMA4x and NEMA12 (indoor only)
if the thickness of the mounting plate is less than the minimum
plate thickness specified in the operating instructions. The
mounting frame has been specially developed for plate thicknesses of less than 2 mm.

2

Depending on the device, different mounting clips are available
for attaching the panel.
Memory card locks (snappable and slideable) are also available
to secure memory cards in the SIMATIC HMI Comfort Panels.
• Push Button Panel
• Key Panel
• Text Display
• Operator Panel
• Touch Panel
• Multi Panel
• Basic Panel
• Comfort Panel
Note regarding Industrial USB Hub 4:
The mounting frame is only available in the service pack
6AV6671-3EA01-0AX0.

■ Technical specifications
6AV6671-3CS00-0AX0

6AV6671-3CS01-0AX0

6AV6671-8XS00-0AX0

Mounting frame 8" Touch

Mounting frame 8" Key

Mounting frame 10" to 12"
Touch devices

Installation type/mounting
Mounting in portrait format possible

Yes

Yes

Yes

Mounting in landscape format possible

Yes

Yes

Yes

Standards, approvals, certificates
CE

Yes

Yes

Yes

Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.

55 °C
0 °C

55 °C
0 °C

55 °C
0 °C

Storage/transport temperature
• Min.
• max.

-20 °C
70 °C

-20 °C
70 °C

-20 °C
70 °C

Relative humidity
• max. relative humidity

90 %

90 %

90 %

Mechanics/material
Type of housing (front)
• Sheet steel

Yes

Yes

Yes

Scope of supply
Delivery unit in items

1

1

1

other
Note:

For MP 277 8" Touch

For MP 277 8" Key

For KTP1000 Basic, MP 277 10"
Touch, MP 377 12" Touch,
Thin Client 10"

2/130

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
SIMATIC HMI Accessories
Fasteners

■ Technical specifications (continued)
6AV6671-8XK00-0AX2

6AV6671-8XK00-0AX1

6AV6671-8XK00-0AX0

Mounting clip, plastic

Mounting clip, spring

Mounting clip, aluminum

Installation type/mounting
Mounting in portrait format possible

Yes

Yes

Yes

Mounting in landscape format possible

Yes

Yes

Yes

Standards, approvals, certificates
CE

Yes

Yes

Yes

Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.

55 °C
0 °C

55 °C
0 °C

55 °C
0 °C

Storage/transport temperature
• Min.
• max.

-20 °C
70 °C

-20 °C
70 °C

-20 °C
70 °C

Relative humidity
• max. relative humidity

90 %

90 %

90 %

Mechanics/material
Screw type
• 4.5 V

Yes; Original partially Phillips screw

Type of housing (front)
• Plastic
• Aluminum

Yes

2

Yes
Yes
Yes

Dimensions
Width

30 mm

20 mm

15 mm

Height

17 mm; Without screw

35 mm

21 mm; Without screw

Thickness

8 mm

20 mm

15 mm

Weight
Weight without packaging

4 g; Per unit

8 g; Per unit

5 g; Per unit

Scope of supply
Delivery unit in items

20

20

20

TD17, OP7/17/73, OP77A/B,
TP/OP170, KP300 mono,
KTP400 color, TP/OP177 except
TP177 4", MP270-6T, TP/OP270-6"

TP177-4", TP/OP 277-6", MP177-6,
MP277-10" T, MP277-8", MP277-8"T,
MP277-10"K, MP377 12-19", TC 10",
TC 15", KTP400 Basic mono,
KTP600, KTP1000, KTP1500,
KP700 Comfort, TP700 Comfort,
KP900 Comfort, TP900 Comfort,
KP1200 Comfort, TP1200 Comfort
and IPC 277D 7, 9, 12"

TP177-4", TP/OP 277-6", MP177-6,
MP277-10" T, MP277-8", MP277-8"T,
MP277-10"K, MP377 12-19", TC 10",
TC 15", KTP400 Basic mono,
KTP600, KTP1000, KTP1500,
KP700 Comfort, TP700 Comfort,
KP900 Comfort, TP900 Comfort,
KP1200 Comfort, TP1200 Comfort
and IPC 277D 7, 9, 12"

other
Note:

Siemens ST 80 / ST PC · 2013

2/131

© Siemens AG 2013

Operator panels
SIMATIC HMI Accessories
Fasteners

■ Technical specifications (continued)

2

6AV6671-8XK00-0AX3

6AV6671-8XK00-0AX4

Mounting clip, steel

Mounting bracket, steel

Installation type/mounting
Mounting in portrait format possible

Yes

Yes

Mounting in landscape format possible

Yes

Yes

Standards, approvals, certificates
CE

Yes

Yes

Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.

55 °C
0 °C

55 °C
0 °C

Storage/transport temperature
• Min.
• max.

-20 °C
70 °C

-20 °C
70 °C

Relative humidity
• max. relative humidity

90 %

90 %

Mechanics/material
Screw type
• 4.5 V

Yes

Yes

Type of housing (front)
• Sheet steel

Yes

Yes

Dimensions
Width

20 mm

142 mm

Height

15 mm; Without screw

18 mm; Without screw

Thickness

8 mm

8 mm

Scope of supply
Delivery unit in items

20

10

15", 19" and 22" widescreen - Comfort Panels, IPCs, Flat
Panels and Thin Clients. Plate thicknesses up to 6 mm

15", 19" and 22" widescreen - Comfort Panels, IPCs, Flat
Panels and Thin Clients, except SCD1900 19" widescreen. Plate thicknesses up to 6 mm

other
Note:

2/132

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
SIMATIC HMI Accessories
Fasteners

■ Technical specifications (continued)
6AV2181-4DM10-0AX0

6AV2181-4XM00-0AX0

Memory card lock 4"

Memory card lock 7" - 22"

Installation type/mounting
Wall mounting/direct mounting possible

Yes; Snap-on

Yes; Snap-on

Degree and class of protection
IP (at the front)

20

20

Standards, approvals, certificates
CE

Yes

Yes

Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.

55 °C
0 °C

55 °C
0 °C

Storage/transport temperature
• Min.
• max.

-20 °C
70 °C

-20 °C
70 °C

Relative humidity
• max. relative humidity

90 %

90 %

Mechanics/material
Plastic

Yes

Yes

Dimensions
Width

25 mm

45 mm

Height

30 mm

59 mm

Thickness

10 mm

12 mm

Weight
Weight without packaging

4 g; Per unit

6 g; Per unit

Scope of supply
Delivery unit in items

5

5

other
Note:

Comfort Panel 4"

Comfort Panels 7" to 22"

2

Siemens ST 80 / ST PC · 2013

2/133

© Siemens AG 2013

Operator panels
SIMATIC HMI Accessories
Fasteners

■ Ordering data
Mounting frame 8" Touch

Order No.
6AV6671-3CS00-0AX0

For contents and matching devices,
see Technical Data and Mall
Mounting frame for 8" Key

2

4" memory card lock
6AV6671-3CS01-0AX0

For contents and matching devices,
see Technical Data and Mall
Mounting frame 10"/12" Touch

Order No.
Mounts and interlocks

7" … 22" memory card lock
6AV6671-8XS00-0AX0

6AV2181-4DM10-0AX0

For contents and matching devices,
see Technical Data and Mall
6AV2181-4XM00-0AX0

For contents and matching devices,
see Technical Data and Mall

For contents and matching devices,
see Technical Data and Mall
Mounting clip/bracket
Plastic mounting clip

6AV6671-8XK00-0AX2

For contents and matching devices,
see Technical Data and Mall
Spring mounting clip

6AV6671-8XK00-0AX1

For contents and matching devices,
see Technical Data and Mall
Aluminum mounting clip

6AV6671-8XK00-0AX0

For contents and matching devices,
see Technical Data and Mall
Steel mounting clip

6AV6671-8XK00-0AX3

For contents and matching devices,
see Technical Data and Mall
Steel mounting bracket

6AV6671-8XK00-0AX4

For contents and matching devices,
see Technical Data and Mall

Note:
This catalog only includes accessories for current products.
The complete range of accessories can be found in the Mall:
https://eb.automation.siemens.com
or on our SIMATIC Support pages:
http://support.automation.siemens.com

2/134

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
SIMATIC HMI Accessories
Labeling strips

■ Overview
Labeling strips and membranes are available for:
• Text display
• Multi Panel
• Mobile Panel
The labeling strips, blank membranes, and protective
membranes should be printed at a printing works.
Templates can be used to create labeling strips for SIMATIC HMI
devices. Alternatively, a tool for the creation of labeling strips is
available.
Download templates from:
http://support.automation.siemens.com/WW/view/en/11274631
and
download Label Creator from:
http://support.automation.siemens.com/WW/view/en/61507590
Labeling strips

Protective cover for labeling strips for Mobile Panel 170,
Mobile Panel 177

■ Technical specifications
6AV6574-1AB044AA0

6AV6671-5BF000AX0

6AV6574-1AB002BA0

6ES7272-1BF007AA0

6ES7272-1AF007AA0

6AV6671-0AP000AX0

Protective
sleeve labeling
strips

Labeling set
Mobile
Panel 277

Labeling strip
MP 37x Key

Front membrane TD100C,
blank

Front membrane TD200C,
blank

Front membrane TD400C,
blank

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Standards, approvals, certificates
CE

Yes

Yes

Yes

Yes

Yes

Yes

Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.

50 °C
0 °C

50 °C
0 °C

50 °C
0 °C

50 °C
0 °C

50 °C
0 °C

50 °C
0 °C

Storage/transport temperature
• Min.
• max.

-20 °C
60 °C

-20 °C
60 °C

-20 °C
60 °C

-20 °C
60 °C

-20 °C
60 °C

-20 °C
60 °C

Relative humidity
• max. relative humidity

90 %

90 %

90 %

90 %

90 %

90 %

Installation type/mounting
Mounting in portrait format possible
Mounting in landscape format possible

Siemens ST 80 / ST PC · 2013

2/135

2

© Siemens AG 2013

Operator panels
SIMATIC HMI Accessories
Labeling strips

■ Technical specifications (continued)

2

6AV6574-1AB044AA0

6AV6671-5BF000AX0

6AV6574-1AB002BA0

6ES7272-1BF007AA0

6ES7272-1AF007AA0

6AV6671-0AP000AX0

Protective
sleeve labeling
strips

Labeling set
Mobile
Panel 277

Labeling strip
MP 37x Key

Front membrane TD100C,
blank

Front membrane TD200C,
blank

Front membrane TD400C,
blank

Films
Number of films per sheet

6

3

2

Yes

Yes

Yes

Yes

Yes

Dimensions
Width

210 mm

210 mm

210 mm

210 mm

210 mm

Height

297 mm

297 mm

297 mm

297 mm

297 mm

printable with laser printer

6
No

Width of the housing front

163 mm

Height of housing front

91 mm

Scope of supply
Delivery unit in items

5

Number of sets
other
Note:

for Mobile Panel
170, Mobile Panel
177

■ Ordering data
Protective cover
for Mobile Panel 17x

2

1

10

10

10

6

2

60

30

20

For Mobile Panel
277

For MP 370 Key,
MP 377 Key

For TD100C

For TD200C

For TD400C

Order No.
6AV6574-1AB04-4AA0

This catalog only includes accessories for current products.

For contents and matching devices,
see Technical Data in the Mall
Labeling set for Mobile Panel 277

6AV6671-5BF00-0AX0

6AV6574-1AB00-2BA0

For contents and matching devices,
see Technical Data in the Mall
Front membrane TD100C,
unprinted

6ES7272-1BF00-7AA0

For contents and matching devices,
see Technical Data in the Mall
Front membrane TD200C,
unprinted

6ES7272-1AF00-7AA0

For contents and matching devices,
see Technical Data in the Mall
Front membrane TD400C,
unprinted

6AV6671-0AP00-0AX0

For contents and matching devices,
see Technical Data in the Mall

2/136

The complete range of accessories can be found in the Mall:
https://eb.automation.siemens.com
or on our SIMATIC Support pages:
http://support.automation.siemens.com

For contents and matching devices,
see Technical Data in the Mall
Labeling set for MP 377 Key

Note:

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Operator panels
SIMATIC HMI Accessories
Batteries

■ Overview

2

Rechargeable buffer battery for Mobile Panel

Lithium battery for SIMATIC HMI, C7 and S7

■ Technical specifications
W790 84-E1001-B2

6ES7 623-1AE01-5AA0

6AV6 671-5CL00-0AX0

6AV6 671-5AD00-0AX0

Lithium battery
SIMATIC HMI and C7

Lithium battery
SIMATIC HMI, C7 and S7

Main battery Mobile Panel
IWLAN

Rechargeable back-up
battery Mobile Panel

Installation type/mounting
Wall mounting/direct mounting possible

Yes; in HMI devices,
battery compartment

Yes; in HMI devices,
battery compartment

Yes; in HMI devices,
battery compartment

Yes; in HMI devices,
battery compartment

Supply voltage
Type of supply voltage

DC

DC

DC

DC

Rated voltage/DC

3.6 V; 1.6 Ah

3.6 V; 1.6 Ah

7.2 V; 5.1 Ah

3.6 V; 1.15 Ah

Battery
Design
• Special design

Yes; 2/3 AA

Yes; 2/3 AA

Yes; bent

Yes; flat

Technology
• Lithium-ion

Yes; SL-361

Yes; SL-361

Yes; 2ICR19/65-2 CGR

Yes; 1/CP7/34/50 01 CGA

Standards, approvals, certificates
CE

Yes

Yes

Yes

Yes

Ambient conditions
Operating temperature
• Operating temperature range, max.
• Operating temperature range, min.

55 °C
0 °C

55 °C
0 °C

55 °C
0 °C; Don't charge below

55 °C
0 °C; Don't charge below

Storage/transport temperature
• Min.
• max.

-20 °C
70 °C

-55 °C
85 °C

-20 °C
70 °C

-20 °C
70 °C

Relative humidity
• max. relative humidity

90 %

90 %

90 %

90 %

75 mm

35 mm

Height

33 mm; Length

33 mm; Length

78 mm

50 mm

Thickness

14.7 mm; Diameter

14.7 mm; Diameter

33 mm

10 mm

Weight
Weight without packaging

12 g

14 g

320 g

38 g

1; incl. 220 mm connecting
cable

1; Incl. 45 mm + 210 mm
connecting cable

1

1; incl. 65 mm connecting
cable

for TD17, OP17, OP25,
OP27, OP35, OP37, TP27,
TP37, OP/TP270, MP 270,
MP 270B, MP 370, C7-621,
C7-623, C7-624, C7-626
and PG 7xx

for TD17, OP17, OP25,
OP27, OP35, OP37, TP27,
TP37, OP/TP270, MP 270,
MP 270B, MP 370, C7-621,
C7-623, C7-624, C7-626
and PG 7xx

for Mobile Panel 277
IWLAN, Mobile Panel 277F
IWLAN, Mobile Panel 277
IWLAN V2, Mobile Panel
277F IWLAN V2, Mobile
Panel 277F IWLAN (RFID
tag)

for Mobile Panel DP cabled,
Mobile Panel PN cabled,
Mobile Panel 277 IWLAN,
Mobile Panel 277F IWLAN

Dimensions
Width

Scope of supply
Delivery unit in items
other
Note:

Siemens ST 80 / ST PC · 2013

2/137

© Siemens AG 2013

Operator panels
SIMATIC HMI Accessories
Batteries

■ Ordering data
Lithium battery for SIMATIC HMI
and C7

Order No.
W79084-E1001-B2

This catalog only includes accessories for current products.

For contents and matching devices,
see Technical Data
Lithium battery for
SIMATIC PG7xx, HMI and C7

2

6ES7623-1AE01-5AA0

6AV6671-5CL00-0AX0

For contents and matching devices,
see Technical Data
Rechargeable buffer battery for
Mobile Panel

6AV6671-5AD00-0AX0

For contents and matching devices,
see Technical Data

2/138

The complete range of accessories can be found in the Mall:
https://eb.automation.siemens.com
or on our SIMATIC Support pages:
http://support.automation.siemens.com

incl. 250 mm adapter cable
Main rechargeable battery for
Mobile Panel IWLAN

Note:

Siemens ST 80 / ST PC · 2013

3

© Siemens AG 2013

HMI devices
for special requirements
3/2

Introduction

3/3
3/4
3/7
3/12
3/14
3/16
3/16
3/17
3/19
3/20

Fully enclosed HMI devices
SIMATIC MP 377 PRO
SIMATIC HMI IPC477C PRO
SIMATIC Flat Panel PRO
SIMATIC Thin Client PRO
Accessories
for fully enclosed HMI devices
Adapter sets
Extension units
IP65 keyboards
USB interfaces

3/21
3/22

Devices with stainless steel front
SIMATIC HMI IPC677C INOX

3/25
3/26
3/30

HMI devices for hazardous areas
SIMATIC HMI Panel PC Ex
SIMATIC HMI Thin Client Ex

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

HMI devices for special requirements
Introduction
■ Overview
Fully enclosed HMI devices
The fully enclosed SIMATIC HMI devices (MP 377 PRO,
HMI IPC477C PRO, Flat Panel PRO and Thin Client PRO) are
specially designed for mounting on a support arm/stand. Thanks
to their extremely rugged design, the devices are ideal for industrial applications in harsh environments.
Devices with stainless steel front
For special requirements, the HMI IPC677C INOX with stainless
steel front for use in the food and beverages industry.
HMI devices for hazardous areas

3

The SIMATIC HMI Ex devices (HMI Panel PC Ex and HMI Thin
Client Ex) are intrinsically safe Panel PCs and Thin Clients that
have been specially developed for hazardous areas "Zone 1"
and "Zone 2". Further SIMATIC HMI devices are also available for
the hazardous area "Zone 2" and can be found in the chapter
"Operator panels".

3/2

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

HMI devices for special requirements
Fully enclosed HMI devices
Overview

■ Overview
The SIMATIC HMI PRO devices can be mounted direct on the
support arm head of the desired support arm system using the
basic adapter supplied. The adapter set can be ordered
separately. The basic adapter can be attached to the top or
bottom of the device. The connecting cables are run through the
support arm.
With the extension units, the range of possible on-site operations
can be expanded. The extension units can be mounted on the
right and/or left side of the SIMATIC HMI PRO device and can be
equipped individually with, for example, illuminated
pushbuttons, emergency stop buttons, RFID readers, etc.

The SIMATIC HMI PRO (PRO = protected) devices have been
designed for mounting on a support arm/pedestal. Thanks to
their rugged aluminum enclosures, the SIMATIC HMI PRO
devices offer overall IP65 protection and are also suitable for use
in harsh environments. The separation of HMI and control
cabinet allows flexible design concepts.
The SIMATIC HMI PRO devices are used wherever the HMI
device cannot be installed direct in the control cabinet due to
restricted space, or whenever an operator control unit is
required direct at the machine. All the devices are fan-free,
and only standard connecting cables are used.

The following are available as SIMATIC fully enclosed
HMI devices:
• SIMATIC MP 377 PRO 15" Touch:
Multi Panel for operator control and monitoring of machines
and plants
• SIMATIC HMI IPC477C PRO 15"/19" Touch:
Compact, high-performance and maintenance-free
embedded IPC
• SIMATIC Flat Panel PRO 15"/19" Touch:
Industrial monitor with touch functionality, can be located up
to 30 m from the operator control unit
(as with Flat Panel Extended)
• SIMATIC Thin Client PRO 15" Touch:
HMI device for terminal and web client applications

Siemens ST 80 / ST PC · 2013

3/3

3

© Siemens AG 2013

HMI devices for special requirements
Fully enclosed HMI devices
SIMATIC MP 377 PRO

■ Overview

■ Technical specifications
MP 377 PRO 15"

15" (304.1 mm x 228.1 mm)

Display type

TFT, 65536 colors

Resolution (pixels)
• Resolution (WxH in pixel)

1024 x 768

Backlighting
• MTBF backlighting (at 25 °C)

about 50000 hours

Control elements
Control elements

Touch screen

Connection for mouse/keyboard/
barcode reader

3
SIMATIC MP 377 PRO 15"

Analog, resistive

Supply voltage
Supply voltage

24 V DC

Input current
Rated current

1.8 A

Memory
Type

Flash / RAM

Time of day
Clock
• Type
Interfaces
Interfaces

Siemens ST 80 / ST PC · 2013

USB / USB / USB

Touch operation
• Touch screen

Usable memory for user data

3/4

6AV6 644-2AB01-2AX0

Display
Size

12288 KB usable memory for user
data / 12288 KB additional memory
for options

Hardware clock, battery backup,
synchronizable
1 x RS422, 1 x RS485,
2 x Ethernet (RJ45)

USB port

2 x USB

CF card slot

1 x CF card slot

Multi Media Card slot

1 x Multi Media Card slot

Industrial Ethernet
• Industrial Ethernet interface

2 x Ethernet (RJ45)

Protocols
Protocols (terminal link)
• Sm@rtServer

Yes

Degree and class of protection
Front

IP65, NEMA 4, (when installed)

Rear

IP65

Standards, approvals, certificates
Certifications

CE, cULus, C-TICK, NEMA 4

FM Class I Div. 2

No

Suitable for safety functions

No

Use in hazardous areas
• EX zone 22

No

© Siemens AG 2013

HMI devices for special requirements
Fully enclosed HMI devices
SIMATIC MP 377 PRO

■ Technical specifications (continued)
MP 377 PRO 15"
Ambient conditions
Mounting position
maximum permissible angle of
inclination without external ventilation

6AV6 644-2AB01-2AX0
vertical
+/- 45 °

MP 377 PRO 15"

6AV6 644-2AB01-2AX0

Functionality under
WinCC (TIA Portal) (continued)
Lists
• Number of text lists per project
• Number of graphics lists per project

500
500

Operating temperature
• Operation

0 °C to +45 °C

Storage/transport temperature
• Transport, storage

-20 °C to +60 °C

Relative humidity
• max. relative humidity

85 %

Archiving
• Number of archives per device
• Number of measuring points per
project
• Number of entries per archive
• external evaluation

Operating systems
Operating system

Windows CE

• Size of archive

WinCC flexible Standard Version
2008 or higher (to be ordered
separately)

Security
• Number of user groups
• Number of user rights
• Password export/import

50
32
Yes

Data carrier support
• CF card

Yes

Configuration
Configuration software
• Configuration tool

Languages
Online languages
• Number of online/runtime languages

5

Logging through printer
• Recording/Printing

Functionality under
WinCC (TIA Portal)
Libraries

Yes

Task planner

Yes

With alarm logging system
(incl. buffer and acknowledgment)
• Number of messages
• Bit messages
• Analog messages

4 000
Yes
Yes

Recipes
• Number of recipes
• Data records per recipe
• Entries per data record
• Recipe memory
Variables
• Number of variables per device

Process coupling
• Connection to controller

• Limit values
• Multiplexing
Images
• Number of configurable images

500

Image objects
• Text objects
• Graphics object

30000 text elements
Bit maps, icons, vector graphics

50 000
Readable, e.g. with MS Excel,
MS Access, etc.
depending on free memory on ext.
card/stick or on free hard disk space
via network drive

Alarms, report (shift report), color
print, hardcopy
MPI/PROFIBUS DP, serial, USB,
Ethernet, by means of external
storage medium, automatic transfer
recognition

• S7-1200
• S7-1500

S5, S7-200, S7-300/400, TI 505,
Win AC, PC (TCP/IP), SINUMERIK,
SIMOTION, Allen Bradley (DF1),
Allen Bradley (DF485), Mitsubishi
(FX), OMRON (LINK/Multilink),
Modicon (Modbus),
further non-Siemens drivers,
see chapter "System interfaces"
Yes
Yes

Expandability/openness
• Open Platform Program

Yes

I/O
I/O devices
• Multi Media Card

Printer, card reader, barcode reader
Yes

Dimensions
Front of enclosure (W x H)

400 mm x 310 mm

Weight
Weight

7.25 kg

500
1 000
1 000
128 KB integrated Flash,
expandable
4 096; Configuration with
WinCC flexible 2008 and higher
Yes
Yes

Complex image objects
• Status/control
• dynamic objects

Transfer (upload/download)
• Transfer of configuration

50
50

With SIMATIC S7
Diagrams, bar graphs, sliders,
analog display, invisible buttons

Siemens ST 80 / ST PC · 2013

3/5

3

© Siemens AG 2013

HMI devices for special requirements
Fully enclosed HMI devices
SIMATIC MP 377 PRO

■ Ordering data

■ More information

Order No.

SIMATIC MP 377 PRO 15" Touch

Additional information is available on the Internet at:

6AV6644-2AB01-2AX0

15" color TFT display,
12 MB configuration memory,
can be configured from
WinCC Comfort (TIA Portal)
or from WinCC flexible 2008

http://www.siemens.com/ip65-hmi-devices
Note:

Note:
An adapter plate is required for mounting on the support arm
systems of well-known manufacturers; see "Accessories for fully
enclosed HMI devices".

■ Dimensional drawings
All dimensions in mm. For installation cutout, see technical
specifications.

3

310

400

SIMATIC MP 377 PRO 15" Touch

3/6

Siemens ST 80 / ST PC · 2013

G_ST80_XX_00351

67.85

98.5

Do you require a specific modification or extension to the
products described here? Under "Customized products" you
can find information about additional and generally available
products for the sector, and about the possibilities for
customized modification and adaptation.

© Siemens AG 2013

HMI devices for special requirements
Fully enclosed HMI devices
SIMATIC HMI IPC477C PRO

■ Overview

3
SIMATIC HMI IPC477C PRO 19"

SIMATIC HMI IPC477C PRO 19" (rear view)

■ Technical specifications
HMI IPC477C PRO

6AV7 883-6….-…. 15"

6AV7 883-7….-…. 19"

Supply voltage

24 V DC

24 V DC

Processors

Intel Celeron M 1.2 GHz, Intel Core2 Solo 1.2 GHz or
Core2 Duo 1.2 GHz

Intel Celeron M 1.2 GHz, Intel Core2 Solo 1.2 GHz or
Core2 Duo 1.2 GHz

Memory type

DDR3-RAM

DDR3-RAM

Main memory

1 GB, 2 GB or 4 GB

1 GB, 2 GB or 4 GB

free slots

1 x CF card slot

1 x CF card slot

Operating system

Windows Embedded Standard 2009,
Windows Embedded Standard 7, Windows 7,
or Windows XP Professional Multi Language

Windows Embedded Standard 2009,
Windows Embedded Standard 7, Windows 7,
or Windows XP Professional Multi Language

Additional OS information

Language: EN/DE

Language: EN/DE

SIMATIC Software

Optionally with pre-installed bundle software
SIMATIC WinCC flexible 2008 or WinCC RT Advanced
and/or SIMATIC WinAC RTX / RTX F 2010,
SIMATIC WinCC or WinCC RT Professional as web client
or standard client

Optionally with pre-installed bundle software
SIMATIC WinCC flexible 2008 or WinCC RT Advanced
and/or SIMATIC WinAC RTX / RTX F 2010,
SIMATIC WinCC or WinCC RT Professional as web client
or standard client

Floppy drive

optional via external USB floppy drive

optional via external USB floppy drive

Optical drives

possible as an external drive via USB

possible as an external drive via USB

Hard disk/mass storage

CompactFlash drive with 4, 8, or 16 GB
and/or 50 GB SSD (High Endurance)

CompactFlash drive with 4, 8, or 16 GB
and/or 50 GB SSD (High Endurance)

General features

Drives

Siemens ST 80 / ST PC · 2013

3/7

© Siemens AG 2013

HMI devices for special requirements
Fully enclosed HMI devices
SIMATIC HMI IPC477C PRO

■ Technical specifications (continued)
HMI IPC477C PRO

6AV7 883-6….-…. 15"

6AV7 883-7….-…. 19"

Graphics interface

DVI-I can be used for additional display unit
(only VGA via adapter); 32-bit color depth, graphics
memory up to 128 MB; resolution as for integrated
display in each case

DVI-I can be used for additional display unit
(only VGA via adapter); 32-bit color depth, graphics
memory up to 128 MB; resolution as for integrated
display in each case

Connection for keyboard/mouse

USB / USB

USB / USB

serial interface

COM1: 1 x V.24 (RS232)

COM1: 1 x V.24 (RS232)

PROFIBUS/MPI

Optionally onboard, isolated, max. 12 Mbit/s, no plug-in
card required, CP5611-compatible, not upgradable

Optionally onboard, isolated, max. 12 Mbit/s, no plug-in
card required, CP5611-compatible, not upgradable

PROFINET (RT/IRT)

Optional: 3 x RJ45, CP1616-compatible; not for retrofitting

Optional: 3 x RJ45, CP1616-compatible; not for retrofitting

USB

4 x on rear, USB 2.0 (500 mA)

4 x on rear, USB 2.0 (500 mA)

PROFINET (IE), Ethernet

onboard, 2 x 10/100/1000 Mbit (RJ45 without/with
PROFIBUS), 1 x 10/100/1000 Mbit (RJ45 with PROFINET),
no plug-in card necessary

onboard, 2 x 10/100/1000 Mbit (RJ45 without/with
PROFIBUS), 1 x 10/100/1000 Mbit (RJ45 with PROFINET),
no plug-in card necessary

Multimedia

No

No

Temperature

Yes

Yes

Watchdog

Yes

Yes

DiagBit (similar to S.M.A.R.T.)

Yes (for CF cards and SSD)

Yes (for CF cards and SSD)

Status LEDs

Yes

Yes

Front side according to EN 60529

IP65 all-round to EN 60529 and NEMA4

IP65 all-round to EN 60529 and NEMA4

Vibration load during operation

Tested according to DIN IEC 60068-2-6: 10 to 58 Hz:
0.075 mm, 58 to 200 Hz: 9.8 m/s² (1 g)

Tested according to DIN IEC 60068-2-6: 10 to 58 Hz:
0.075 mm, 58 to 200 Hz: 9.8 m/s² (1 g)

Shock loading during operation

Tested according to DIN IEC 60068-2-7:
50 m/s² (5 g), 30 ms, 100 shocks

Tested according to DIN IEC 60068-2-7:
50 m/s² (5 g), 30 ms, 100 shocks

Relative humidity

Tested according to DIN IEC 68-78, DIN IEC 60068-2-30:
5 % to 80 % at 25 °C (no condensation)

Tested according to DIN IEC 68-78, DIN IEC 60068-2-30:
5 % to 80 % at 25 °C (no condensation)

maximum permissible installation
angle +/-

+/- 45° from the vertical

+/- 45° from the vertical

Ambient temperature

0°C to 45 °C

0°C to 40°C

Approvals

CE, cULus(508)

CE, cULus(508)

EMC

CE, 55022A, EN 61000-6-4, EN 61000-6-2

CE, 55022A, EN 61000-6-4, EN 61000-6-2

Degree of protection

Overall device IP65/enclosure type 4x/type 12
(indoor use only)

Overall device IP65/enclosure type 4x/type 12
(indoor use only)

Dimensions

400 mm x 310 mm x 98 mm

483 mm x 400 mm x 115 mm

Weight

7.4 kg

10.9 kg

3/8

Siemens ST 80 / ST PC · 2013

Interfaces

3

Monitoring functions

Ambient conditions

Certifications & standards

© Siemens AG 2013

HMI devices for special requirements
Fully enclosed HMI devices
SIMATIC HMI IPC477C PRO

■ Ordering data

Order No.

Order No.

IPC477C PRO as "Built to Order" versions
(max. delivery time is 15 working days and with identified repair).
SIMATIC HMI IPC477C PRO
optionally with
WinAC / WinCC flexible

6AV7883- 7 A 7 7 7 - 7 7 7 0

Embedded and fan-free, with IP65
housing with all-round protection;
5 x USB (500 mA),
1 of which on the front
24 V DC power supply
with On/Off switch
Front panels
• 15" TFT Touch (IP65 enclosure)
• 19" TFT Touch (IP65 enclosure)
Processors and fieldbus
• Celeron M 1.2 GHz,
2 x PROFINET (IE)
• Celeron M 1.2 GHz,
2 x PROFINET (IE),
1 x PROFIBUS DP 12
• Core2 Solo 1.2 GHz,
2 x PROFINET (IE)
• Core2 Solo 1.2 GHz,
2 x PROFINET (IE),
1 x PROFIBUS DP 12
• Core2 Solo 1.2 GHz,
1 x PROFINET (IE),
1 x PROFINET (3 ports)
• Core2 Duo 1.2 GHz,
2 x PROFINET (IE)
• Core2 Duo 1.2 GHz,
2 x PROFINET (IE),
1 x PROFIBUS DP 12
• Core2 Duo 1.2 GHz,
1 x PROFINET (IE),
1 x PROFINET (3 ports)
Main memory
(DDR3 RAM), 1 database
• 1 GB
• 2 GB
• 4 GB
Mass storage swappable
(formatted with a partition)
• None
• CompactFlash 2 GB
• CompactFlash 4 GB
• CompactFlash 8 GB
• CompactFlash 16 GB
• 50 GB SSD (High Endurance)
Mass storage
(with Windows Embedded Standard
2009 (EN/DE) / Windows Embedded
Standard 7 pre-installed and
optionally with SIMATIC software)
• CompactFlash 2 GB
(only with Windows Embedded
Standard 2009)
• CompactFlash 4 GB
• CompactFlash 8 GB
• CompactFlash 16 GB
• 50 GB SSD (High Endurance)

SIMATIC HMI IPC477C PRO
optionally with
WinAC / WinCC flexible (continued)

6AV7883- 7 A 7 7 7 - 7 7 7 0

Operating system
(pre-installed and activated)
• Windows Embedded Standard
2009
• Windows XP Professional
Multi-Language, only with SSD;
without SIMATIC software
• Windows Embedded Standard 7
SP1, pre-installed on internal drive,
CF > 4 GB, SSD, and 2 GB main
memory
• Windows 7 Ultimate, MUI (Eng,
Ger, Fr, It, Sp) pre-installed on SSD

6
7
A
B

BA
DA

E A

GA

Software packages
WinAC / WinCC flexible
CF 4 GB or more and SSD,
only together with
Windows Embedded Standard 2009
or Windows Embedded Standard 7
• With WinAC RTX
pre-installed and configured
for PROFIBUS and with
WinCC flexible 2008 RT
(incl. Archives/Recipes)
pre-installed and configured
- Number of tags 128 PT
- Number of tags 512 PT
- Number of tags 2048 PT
- Number of tags 4096 PT

D
E

F

G
H

J

• With WinAC RTX and WinCC flexible 2008 RT (incl. Archives/Recipes) pre-installed and configured
- Number of tags 128 PT
- Number of tags 512 PT
- Number of tags 2048 PT
- Number of tags 4096 PT
• With WinAC RTX F
pre-installed and configured for
PROFIBUS DP 12
- Number of tags 128 PT

1
2
3

0
2
3
4
5
6

• With WinAC RTX F and
WinCC flexible 2008 RT
(incl. Archives/Recipes),
pre-installed and configured
- Number of tags 512 PT
- Number of tags 2048 PT
- Number of tags 4096 PT

B

C
D
E
F

K
L
M
N
P

R

S
T
U

2

3
4
5
6

Siemens ST 80 / ST PC · 2013

3/9

3

© Siemens AG 2013

HMI devices for special requirements
Fully enclosed HMI devices
SIMATIC HMI IPC477C PRO

■ Ordering data
SIMATIC HMI IPC477C PRO
optionally with
WinAC / WinCC RT Advanced

Order No.
6AV7883-

Order No.
7A777-777 1

Embedded and fan-free, with IP65
housing with all-round protection;
5 x USB (500 mA),
1 of which on the front
24 V DC power supply
with On/Off switch
Front panels
• 15" TFT Touch (IP65 enclosure)
• 19" TFT Touch (IP65 enclosure)

3

Processors and fieldbus
• Celeron M 1.2 GHz,
2 x PROFINET (IE)
• Celeron M 1.2 GHz,
2 x PROFINET (IE),
1 x PROFIBUS DP 12
• Core2 Solo 1.2 GHz,
2 x PROFINET (IE)
• Core2 Solo 1.2 GHz,
2 x PROFINET (IE),
1 x PROFIBUS DP 12
• Core2 Solo 1.2 GHz,
1 x PROFINET (IE),
1 x PROFINET (3 ports)
• Core2 Duo 1.2 GHz,
2 x PROFINET (IE)
• Core2 Duo 1.2 GHz,
2 x PROFINET (IE),
1 x PROFIBUS DP 12
• Core2 Duo 1.2 GHz,
1 x PROFINET (IE),
1 x PROFINET (3 ports)
Main memory
(DDR3 RAM),1 database
• 2 GB
• 4 GB
Mass storage, removable
• None
• CompactFlash 2 GB
(only with Windows Embedded
Standard 2009)
• CompactFlash 4 GB
• CompactFlash 8 GB
• CompactFlash 16 GB
• 50 GB SSD (High Endurance)
Mass storage, installed
(Windows Embedded Standard 7
pre-installed and optionally with
SIMATIC software)
• CompactFlash 4 GB
• CompactFlash 8 GB
• CompactFlash 16 GB
• 50 GB SSD (High Endurance)

SIMATIC HMI IPC477C PRO
optionally with
WinAC / WinCC RT Advanced
(continued)
Operating system
(pre-installed and activated)
• Windows Embedded Standard 7,
pre-installed on internal drive

6AV7883-

7A777-777 1

E A

Software packages
WinAC / WinCC RT Advanced
• With WinAC RTX
pre-installed and configured
for PROFIBUS and with
WinCC RT Advanced
(incl. Logging & Recipes)
pre-installed and configured
- Number of tags 128 PT
- Number of tags 512 PT
- Number of tags 2048 PT
- Number of tags 4096 PT

6
7
A
B

D

• With WinAC RTX and
WinCC RT Advanced
(incl. Logging & Recipes)
pre-installed and configured
- Number of tags 128 PT
- Number of tags 512 PT
- Number of tags 2048 PT
- Number of tags 4096 PT
• With WinAC RTX F
pre-installed and configured
for PROFIBUS DP 12

E

F

G
H

J

• With WinAC RTX F and WinCC RT
Advanced (incl. Logging & Recipes) pre-installed and configured
- Number of tags 128 PT
- Number of tags 512 PT
- Number of tags 2048 PT
- Number of tags 4096 PT

2
3

B

C
D
E
F

K
L
M
N
P

R
S
T
U

0
2

3
4
5
6

3
4
5
6

Note:
An adapter plate is required for mounting on the support arm
systems of well-known manufacturers; see "Accessories for fully
enclosed HMI devices".
For further bundles with SIMATIC HMI IPC477C PRO with
SIMATIC WinCC V7.0 and SIMATIC WinCC RT Professional
(TIA Portal), see under SIMATIC HMI IPC477C bundles

3/10

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

HMI devices for special requirements
Fully enclosed HMI devices
SIMATIC HMI IPC477C PRO

■ Dimensional drawings

400

348.7

All dimensions in mm. For installation cutout, see technical specifications.

SIMATIC HMI IPC477C PRO 15" Touch version

81.85

78.85

119

482.7

G_ST80_XX_00401

400

G_ST80_XX_00400

105

3

SIMATIC HMI IPC477C PRO 19" Touch version

■ More information
Additional information is available on the Internet at:

Note:

http://www.siemens.com/ip65-hmi-devices

Do you require a specific modification or extension to the
products described here? Under "Customized products" you
can find information about additional and generally available
products for the sector, and about the possibilities for
customized modification and adaptation.

Siemens ST 80 / ST PC · 2013

3/11

© Siemens AG 2013

HMI devices for special requirements
Fully enclosed HMI devices
SIMATIC Flat Panel PRO

■ Overview

3
SIMATIC Flat Panel Monitor PRO 19"

SIMATIC Flat Panel Monitor PRO 15" with expansion unit (rear view)

■ Technical specifications
Flat Panel

PRO 15"

PRO 19"

Supply voltage
Supply voltage

24 V DC and
230 V AC
combined

24 V DC and
230 V AC
combined

permissible frequency range

47 to 63 Hz

47 to 63 Hz

Power consumption, max.

35 VA

35 VA

General features
Can be separate from the computer

Flat Panel

PRO 15"

PRO 19"

Certification

cULus (UL 508),
NEMA4-tested

cULus (UL 508),
NEMA4-tested

EMC

CE EN 55011
class A

CE EN 55011
class A

CE mark

Yes

Yes

UL approval

Yes

Yes

Certifications & standards

up to 30 m

up to 30 m

Display

Standards, approvals, certificates

Ambient conditions

On-screen display (OSD)
configuration

Yes

Yes

Display version

15" TFT

19" TFT

visible area (H x W) in mm

304 x 228

376 x 301

Viewing angle

140° x 120°
(min)

140° x 120°
(min)

Pixel pitch

0.297 mm x
0.297 mm

0.297 mm x
0.297 mm

Inclination angle

Resolution (W x H in pixels)

1024 x 768

1280 x 1024

Interfaces

Refresh rate

60 to 75 Hz

60 to 75 Hz

Line frequency

46.7 - 80 kHz

46.7 - 80 kHz

Brightness/contrast

> 260 cd/m2 /
350:1

> 300 cd/m2 /
300:1

Number of colors

16.7 million

16.7 million

MTBF of backlit display (at 25 °C,
24 hours continuous operation)

50,000 h

50,000 h

Touch screen

analog-resistive

analog-resistive

1 g (10 m/s²)

1 g (10 m/s²)

5 g (50 m/s²)

5 g (50 m/s²)

Temperature
• Ambient temperature during operation

5 to +45 °C

5 to +45 °C

+/- 45° from the
vertical

+/- 45° from the
vertical

Graphics interface

Standard VGA
interface 15-pin
sub-D/digital
DVI-D interface

Standard VGA
interface 15-pin
sub-D/digital
DVI-D interface

Interface for Touch

USB (V1.1)

USB (V1.1)

USB interface for touch screen

Yes

Yes

400 mm x 310
mm x 91 mm

483 mm x 400
mm x 105 mm

Connection for keyboard/mouse/
barcode reader

Yes, via USB

Yes, via USB

Degree of protection

Overall device
IP65/enclosure
type 4x/type 12
(indoor use only)

Overall device
IP65/enclosure
type 4x/type 12
(indoor use only)

6.7 kg

10 kg

Mounting

Dimensions
External dimensions (W x H x D)

Type of operation

3/12

Vibration load during operation
Shock loading during operation

Siemens ST 80 / ST PC · 2013

Weight
Weight

© Siemens AG 2013

HMI devices for special requirements
Fully enclosed HMI devices
SIMATIC Flat Panel PRO

■ Ordering data

■ More information

Order No.

SIMATIC Flat Panel PRO 15"
Touch

6AV7861-5TB10-1BA0

SIMATIC Flat Panel PRO 19"
Touch

6AV7861-6TB10-1BA0

Additional information is available on the Internet at:
http://www.siemens.com/ip65-hmi-devices
Note:

Note:
An adapter plate is required for mounting on the support arm
systems of well-known manufacturers; see "Accessories for fully
enclosed HMI devices".

Do you require a specific modification or extension to the
products described here? Under "Customized products" you
can find information about additional and generally available
products for the sector, and about the possibilities for
customized modification and adaptation.

■ Dimensional drawings
All dimensions in mm. For installation cutout, see technical
specifications.
400

310

3

67.85

G_ST80_XX_00350

90.85

SIMATIC Flat Panel PRO 15" Touch
483

400

SIMATIC FLAT PANEL

G_ST80_XX_00371

82

105

SIMATIC Flat Panel PRO 19" Touch

Siemens ST 80 / ST PC · 2013

3/13

© Siemens AG 2013

HMI devices for special requirements
Fully enclosed HMI devices
SIMATIC Thin Client PRO

■ Overview

■ Technical specifications
Thin Client PRO 15" Touch

15.1"

Display type

TFT, 65536 colors

Resolution (pixels)
• Resolution (WxH in pixel)

1024 x 768

Backlighting
• MTBF backlighting (at 25 °C)

about 50000 hours

Control elements
Control elements

Touch screen

Connection for mouse/keyboard/
barcode reader

3
SIMATIC Thin Client PRO 15"

Analog, resistive

Supply voltage
Supply voltage

24 V DC

Processor
Processor

ARM, 266 MHz

Memory
Type

Flash / RAM

Usable memory for user data

No info

Interfaces
Interfaces

1 x Ethernet (RJ45)

USB port

1 x USB

Industrial Ethernet
• Industrial Ethernet interface

1 x Ethernet (RJ45)

Protocols
WEB characteristics
• HTTP
• HTML
• CSS

Yes
Yes
Yes

Protocols (terminal link)
• Sm@rtServer
• RDP

Yes
Yes

Degree and class of protection
Front
Rear
Standards, approvals, certificates
Certifications

Siemens ST 80 / ST PC · 2013

USB / USB

Touch operation
• Touch screen

EMC
Emission of radio interference
acc. to EN 55 011
• Emission of radio interferences
acc. to EN 55 011 (limit class A)

3/14

6AV6646-2AB21-2AX0

Display
Size

Yes; EN 61000-6-4, interference
emission: Intended for use in
industrial areas.
IP65, NEMA 4x, NEMA 12
(when installed)
IP65
CE, cULus, C-TICK,
NEMA 4x (Enclosure Type 4X,
Type 12), NEMA 12

EMC

The product is designed for use in
industrial environments. When used
in residential areas, the emission of
radio interference according to limit
class B of EN 55011 must be
ensured. For further information
please refer to the user documentation.

Suitable for safety functions

No

© Siemens AG 2013

HMI devices for special requirements
Fully enclosed HMI devices
SIMATIC Thin Client PRO

■ Technical specifications (continued)

400
0 °C to +45 °C

Storage/transport temperature
• Transport, storage

-20 °C to +60 °C

Relative humidity
• max. relative humidity

85 %; (Storage)

Dimensions
Front of enclosure (W x H)

400 mm x 310 mm

Weight
Weight

6.5 kg

SIMATIC Thin Client PRO 15"
Touch

All dimensions in mm. For installation cutout, see technical
specifications.

+/- 45 °

Operating temperature
• Operation

■ Ordering data

■ Dimensional drawings

3

Order No.
6AV6646-2AB21-2AX0

90.85

SIMATIC Thin Client with
Sm@rtAccess
• Touch device 15" PRO with
Sm@rtAccess license (panels)
• Touch device 15" PRO with
Sm@rtAccess license for
WinCC flexible 2008 Runtime

67.85

Starter packages

6AV6653-6CA01-2AA0
6AV6653-6FA01-2AA0

Note:
An adapter plate is required for mounting on the support arm
systems of well-known manufacturers; see "Accessories for fully
enclosed HMI devices".

G_ST80_XX_00350

Ambient conditions
maximum permissible angle of
inclination without external ventilation

6AV6646-2AB21-2AX0

310

Thin Client PRO 15" Touch

SIMATIC Thin Client PRO 15" Touch

■ More information
Additional information is available on the Internet at:
http://www.siemens.com/ip65-hmi-devices
Note:
Do you require a specific modification or extension to the
products described here? Under "Customized products" you
can find information about additional and generally available
products for the sector, and about the possibilities for
customized modification and adaptation.

Siemens ST 80 / ST PC · 2013

3/15

© Siemens AG 2013

HMI devices for special requirements
Accessories for fully enclosed HMI devices
Adapter sets

■ Overview

■ More information

Adapter sets
• The adapter sets are required for connecting the
SIMATIC HMI PRO device with the support arm head of the
respective support arm system
• By directly connecting the support arm head to the device,
there is complete flexibility in the choice of support arm
components
• Adapter sets are available for the VESA 75 and
VESA 100 systems.
• Further adapter sets can be obtained directly from the
respective supporting bracket manufacturer: Bernstein, Rittal,
Rose and Haseke

■ Ordering data

3

Order No.

VESA 100 adapter set 1) for
• VESA 100
• Rose GTN II

6AV7674-0KD00-0AA0

Adapter set VESA 75 for
• VESA 75

6AV7674-0KE00-0AA0

Replacement basic adapter,
suitable for
SIMATIC HMI PRO devices

6AV7674-0KA00-0AA0

1)

The VESA 100 adapter set cannot be used in combination
with the 19" Flat Panel PRO.

Note:
The internal diameter of the 48 mm supporting bracket tubes is
not suitable for passage of the standard DVI-D cable.
Scope of delivery:
• One basic adapter or one adapter plate
• Mounting hardware

3/16

Siemens ST 80 / ST PC · 2013

Additional information is available on the Internet at:
http://www.siemens.com/ip65-hmi-devices
Note:
Do you require a specific modification to or option for the
products described here? Under "Customized products" you
can find information about additional and generally available
products for the sector, and about the possibilities for
customized modification and adaptation.

© Siemens AG 2013

HMI devices for special requirements
Accessories for fully enclosed HMI devices
Extension units

■ Overview

■ Ordering data

Order No.

Extension Unit 15"

6AV7674-0KG00-0AA0

For mounting on all 15" PRO devices

Extension units
With the extension units, the range of possible on-site operations
can be extended. They are mounted on the SIMATIC HMI PRO
device and can be equipped individually, e.g. with Key Panel
(KP8), 3SB elements, emergency stop buttons, key switches,
RFID reader, etc.
• They can be mounted on the left or right side of the
PRO device, as required
• Direct installation of up to 2 Key Panels KP8 / KP8F
• IP65 - cable routing
• Can be equipped individually
• For all 15"/19" PRO devices
The combination of HMI PRO device and KP8 PN offers the
following advantages:
• No control cabinet required
• Low cabling overhead
• Optimally coordinated design

Extension Unit 15" KP8
For mounting on all 15" PRO devices
for direct installation of up to
2 KP8 / KP8F

6AV7674-0KG01-0AA0

Starter package Extension Unit
15" with KP8
1 x Extension Unit 15" KP8,
1 x Key Panel 8 PN,
1 x blank front

6AV7674-0KG11-0AA0

Extension Unit 19" right
• For support arm mounting
from above
Mounting of the Extension Unit on
the right side of the 19" PRO device
• For support arm mounting
from below
Mounting of the Extension Unit on
the left side of the 19" PRO device

6AV7674-0KJ00-0AA0

Extension Unit 19" KP8 right
• For support arm mounting
from above
Mounting of the Extension Unit on
the right side of the 19" PRO device
• For support arm mounting
from below
Mounting of the Extension Unit on
the left side of the 19" PRO device
• For direct installation of
up to 2 KP8 / KP8F

6AV7674-0KJ01-0AA0

Starter package Extension Unit
19" with KP8 right
1 x Extension Unit 19" KP8 right,
1 x Key Panel 8 PN,
1 x blank front

6AV7674-0KJ11-0AA0

Extension Unit 19" left
• For support arm mounting
from above
Mounting of the Extension Unit on
the left side of the 19" PRO device
• For support arm mounting
from below
Mounting of the Extension Unit on
the right side of the 19" PRO device

6AV7674-0KH00-0AA0

Starter package Extension Unit
19" with KP8 left
1 x Extension Unit 19" KP8 left,
1 x Key Panel 8 PN,
1 x blank front

6AV7674-0KH11-0AA0

Extension Unit 19" KP8 left
• For support arm mounting
from above
Mounting of the Extension Unit on
the left side of the 19" PRO device
• For support arm mounting
from below
Mounting of the Extension Unit on
the right side of the 19" PRO device
• For direct installation of up to
2 KP8 / KP8F

6AV7674-0KH01-0AA0

3

Siemens ST 80 / ST PC · 2013

3/17

© Siemens AG 2013

HMI devices for special requirements
Accessories for fully enclosed HMI devices
Extension units

■ Ordering data

3

Order No.

KP8 front plate
for the Extension Unit
• For installing up to two KP8
in an Extension Unit
• Suitable for all 15" and 19"
Extension Units

6AV7674-0KH30-0AB0

Empty front KP8 design
in combination
with front panel KP8

6AV3688-3XY38-3AX0

Spare front plate
for the Extension Unit
• Suitable for all 15" and 19"
Extension Units
• Required if the front plate supplied
with the Extension Unit must be replaced

6AV7674-0KH30-0AA0

Additional information is available on the Internet at:
http://www.siemens.com/ip65-hmi-devices
Note:

Scope of delivery:
• 1 Extension Unit box
• 1 front plate for the Extension Unit
• 1 connecting tube
• Mounting accessories

3/18

■ More information

Siemens ST 80 / ST PC · 2013

Do you require a specific modification to or option for the
products described here? Under "Customized products" you
can find information about additional and generally available
products for the sector, and about the possibilities for
customized modification and adaptation.

© Siemens AG 2013

HMI devices for special requirements
Accessories for fully enclosed HMI devices
IP65 keyboards

■ Overview

■ More information

IP65 keyboards

Additional information is available on the Internet at:

With the stainless steel IP65 keyboards, the range of possible
on-site operations can be extended. They are mounted on the
SIMATIC HMI PRO device underneath the base adapter, and
they are available in two versions.
• Anti-twist and non-removable stainless steel key caps
• Abrasion-resistant laser labeling
(depth engraving with annealing marking)
• Secure, pleasant key feel
• Maximum user-friendliness thanks to withdrawable
long-stroke key
• Windows layout (EN/US) with two additional keys
(left and right mouse key function) via cursor block
• USB interface
• Angle-adjustable connection for optimal ergonomics
• Water and dust protection in accordance with degree of
protection IP65
• For all 15"/19" PRO devices

http://www.siemens.com/ip65-hmi-devices

■ Ordering data

Note:
Do you require a specific modification to or option for the
products described here? Under "Customized products" you
can find information about additional and generally available
products for the sector, and about the possibilities for
customized modification and adaptation.

3

Order No.

Stainless steel IP65 keyboard 15"
• Width: 400 mm (adapted to
15" SIMATIC HMI PRO)
• Windows layout (EN/US)
without NUM block
• Angle-adjustable adapter

6AV7674-0NC00-0AA0

Stainless steel IP65 keyboard 19"
• Width: 483 mm (adapted to
19" SIMATIC HMI PRO)
• Windows layout (EN/US)
with NUM block
• Angle-adjustable adapter

6AV7674-0NE00-0AA0

Tool and keyboard tray
• Width: 483 mm (adapted to
19" SIMATIC HMI PRO)
• Including 2-port USB interface
• Angle-adjustable adapter

6AV7674-0NE01-0AA0

Scope of delivery:
• One stainless steel IP65 keyboard incl. mounting adapter for
PRO devices
• Mounting accessories

Siemens ST 80 / ST PC · 2013

3/19

© Siemens AG 2013

HMI devices for special requirements
Accessories for fully enclosed HMI devices
USB interfaces

■ Overview

■ More information

• The USB interface is used for connecting external peripheral
devices to the MP 377 PRO, the HMI IPC477C PRO,
the Flat Panels PRO, and the Thin Client PRO.
• USB peripheral devices can thus be connected and operated
without opening the device
• Extension of the internal USB interface externally

■ Ordering data
1-port USB interface

Order No.
6AV7674-0LX00-0AA0

For fully enclosed HMI devices,
length USB cable: 0.5 m
2-port USB interface

3

6AV7674-0LX01-0AA0

For fully enclosed HMI devices,
length USB cable: 0.5 m.
Not suitable for: Thin Client,
MP 377, and Flat Panel

3/20

Siemens ST 80 / ST PC · 2013

Additional information is available on the Internet at:
http://www.siemens.com/ip65-hmi-devices
Note:
Do you require a specific modification to or option for the
products described here? Under "Customized products" you
can find information about additional and generally available
products for the sector, and about the possibilities for
customized modification and adaptation.

© Siemens AG 2013

HMI devices for special requirements
Devices with stainless steel front
Devices with stainless steel front

■ Overview
For special requirements, the following HMI devices with
stainless steel front (DIN EN 1672-2), e.g. for use in the food,
beverages and tobacco industries, are offered.
SIMATIC HMI IPC677C INOX
PC platform with high degree of industrial compatibility for
demanding tasks in the area of PC-based automation.

Note:
Do you require a specific modification to or option for the
products described here? Then look up "Customized products",
where you will find information about additional generallyavailable industry-specific products that can be ordered, as well
as about options for customer-specific modifications and
adaptations.

Rugged construction:
The PC is resistant to the harshest mechanical stress and is
reliable in operation.
• Compact design
• High degree of investment protection
• Fast integration capability
• 15" TFT Touch, stainless steel/INOX
• All interfaces such as PROFIBUS or PROFINET onboard

3

More SIMATIC HMI INOX panels
You will find further INOX industry products, as well as customerspecific product variants, in the "Customized Automation"
section, e.g.
• SIMATIC HMI Flat Panel 15" Touch INOX
• SIMATIC HMI Flat Panel 19" Touch INOX
• SIMATIC HMI Flat Panel 19" Touch INOX fully enclosed

Siemens ST 80 / ST PC · 2013

3/21

© Siemens AG 2013

HMI devices for special requirements
Devices with stainless steel front
SIMATIC HMI IPC677C INOX

■ Overview

■ Technical specifications
HMI IPC677C INOX 15" Touch

6AV789...

General features
Front panel

15" TFT Touch

Display
Screen diagonal

15"

Resolution (W x H in pixels)

1024 x 768

MTBF of backlighting (at 25 °C)

50 000 h at 24 h continuous operation, temperature-dependent

Type of operation
Touch screen

Yes

Design
Central design

Yes

Dimensions

3
PC platform with high degree of industrial compatibility for
demanding tasks in the area of PC-based automation.
Rugged design:
The PC is resistant to the harshest mechanical stress and is
reliable in operation.
• Compact design
• High degree of investment protection
• Fast integration capability
• Front panel versions:
- 15" TFT Touch, stainless steel/INOX

3/22

Siemens ST 80 / ST PC · 2013

Installation cutout/device depth
(W x H x D) in mm

450 x 290 x 142 (incl. optical drive)

Mounting dimensions in centralized
configuration (W x H x D, without
optical drive) in mm

450 x 290 x 121

Additional mounting depth
(optical drive) in mm

21

Weight
HMI IPC in a centralized configuration
approx.

14 kg

© Siemens AG 2013

HMI devices for special requirements
Devices with stainless steel front
SIMATIC HMI IPC677C INOX

■ Ordering data
SIMATIC HMI IPC677C INOX
Front panels
• 15" TFT Touch
Front options
• INOX front, without front USB,
with 15" TFT Touch only
Power supply
• 24 V DC
• 110/230 V AC,
power cable for Europe
• 110/230 V AC, without power cable
• 110/230 V AC, power cable for UK
• 110/230 V AC, power cable for CH
• 110/230 V AC,
power cable for the USA
• 110/230 V AC,
power cable for Italy
• 110/230 V AC,
power cable for China
Processor
• Intel Celeron 1.86 GHz
(2 MB shared cache), 2 cores
• Intel Celeron 1.86 GHz
(2 MB shared cache),
2 cores, PROFIBUS MPI,
2 MB buffered SRAM
• Intel Celeron 1.86 GHz
(2 MB shared cache),
2 cores, PROFINET
(3x RJ45, CP1616-compatible),
2 MB buffered SRAM
• Intel Core i3, 2.13 GHz
(3 MB shared cache),
2 cores, hyper-threading
• Intel Core i3, 2.13 GHz
(3 MB shared cache), 2 cores,
hyper-threading, PROFIBUS MPI,
2 MB buffered SRAM
• Intel Core i3, 2.13 GHz
(3 MB shared cache), 2 cores,
hyper-threading, PROFINET
(3x RJ45, CP1616-compatible),
2 MB buffered SRAM
• Intel Core i7, 2.53 GHz
(4 MB shared cache), 2 cores,
hyper-threading, turbo boost
• Intel Core i7, 2.53 GHz
(4 MB shared cache),
2 cores, hyper-threading,
turbo boost, PROFIBUS MPI,
2 MB buffered SRAM
• Intel Core i7, 2.53 GHz
(4 MB shared cache), 2 cores,
hyper-threading, turbo boost,
PROFINET (3 x RJ45,
CP 1616-compatible),
2 MB buffered SRAM

Order No.

Order No.

6AV789 7 - 7 7 7 7 7 - 7 7 7 7

6AV789 7 - 7 7 7 7 7 - 7 7 7 7

SIMATIC HMI IPC677C INOX
(continued)
Main memory
• 1 GB DDR3
• 2 GB DDR3
• 3 GB DDR3
• 4 GB DDR3
• 8 GB DDR3
• 2 GB DDR3 with ECC
• 4 GB DDR3 with ECC
• 8 GB DDR3 with ECC

2
2

A
B
C
D
E
F
G
H

A
B

C

D

E

F

G

H

J

0
1
2
3
4
5
6
7

Mass storage
• 250 GB SATA hard disk
• 500 GB SATA hard disk
• RAID1 dual hard disk module
2 x 250 GB SATA, preconfigured
• Dual hard disk module
2 x 250 GB SATA
• 50 GB SSD (SLC)
• Second CF card slot
(only in combination with
Windows XP embedded),
internal, empty, only with version
without opt. drive and without HDD
• Without mass storage
Optical drives
• None
• DVD±RW±R combo drive

0
1
2

3

3
4
5

8
0
1

Communication Interfaces
• 2 x PCI available
• 1 x PCI, 1 x PCIe (x16) available

A
B

Operating system
(pre-installed and activated)
• Without operating system
• Windows XP Professional
Multi-Language 1)
• Windows 7 Ultimate 32-bit
Multi-Language 1)
• Windows Embedded Standard
on 8 GB CF card 2)
• Windows 7 Ultimate 64-Bit
Multi-Language 1)

A
B
C
D
E

Software expansion
• None
• SIMATIC IPC DiagMonitor V4.3
enclosed
• SIMATIC IPC Image & Partition
Creator V3.2 enclosed
• SIMATIC IPC DiagMonitor V4.3,
Image & Partition Creator V3.2
enclosed

0
1
2
3

1)

Multi-language means: D/E/F/I/SP/CHIN traditional/CHIN simplified/
Korean/Japanese

2)

Without RAID 1 option only

Siemens ST 80 / ST PC · 2013

3/23

© Siemens AG 2013

HMI devices for special requirements
Devices with stainless steel front
SIMATIC HMI IPC677C INOX

■ Ordering data

Order No.

Non-heating apparatus cable for
SIMATIC Box and Panel PC
SIMATIC PC power cable,
230 V AC, angled, 3 m, for:
• Germany
• United Kingdom
• Switzerland
• USA
• Italy
• China

6ES7900-1AA00-0XA0
6ES7900-1BA00-0XA0
6ES7900-1CA00-0XA0
6ES7900-1DA00-0XA0
6ES7900-1EA00-0XA0
6ES7900-1FA00-0XA0

Touch pen
Captive pen for operation of the
touch devices, mounting of the
support on the control cabinet

6AV7672-1JB00-0AA0

Expansion components

From page 5/153

Communication components

From page 5/186

M

H

6ES7648-2AJ40-0KA0
6ES7648-2AJ50-0KA0
6ES7648-2AJ60-0KA0
6ES7648-2AJ40-1KA0
6ES7648-2AJ50-1KA0
6ES7648-2AJ60-1KA0

G

Memory expansion
• 1 GB DDR3 DIMM
• 2 GB DDR3 DIMM
• 4 GB DDR3 DIMM
• 1 GB DDR3 DIMM with ECC
• 2 GB DDR3 DIMM with ECC
• 4 GB DDR3 DIMM with ECC

J

K

K

G_ST80_XX_00288

3

■ Dimensional drawings
All dimensions in mm.

Accessories

L
N

Panel PC 677C INOX 15" Touch
Control units
PC 677 INOX

G

H

J

K

L

M

N

289

271

138

11

24

367

42

Touch devices
15"

■ More information
Additional information is available in the Internet under:
http://www.siemens.com/inox-hmi-devices
Note:
Do you require a specific modification or supplement to the
products described here? Then refer to "Customized products",
where you will find information about additional sector-specific
products that can be ordered as well as about options for
customer-specific modification and adaptation.

3/24

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

HMI devices for special requirements
HMI devices for hazardous areas
HMI devices for hazardous areas

■ Overview
The SIMATIC HMI Ex devices are intrinsically-safe Panel PCs
and Thin Clients which have been specially developed for
hazardous areas. The intrinsically-safe design allows simple
installation on site. The variety of certification allows use in many
parts of the world without further approvals.

Available as HMI devices for hazardous areas "Zone 1" and
"Zone 2" are:
• SIMATIC HMI Panel PC Ex
• SIMATIC HMI Thin Client Ex

The devices are fanless and permit completely maintenancefree installation without batteries or rotating parts.

Further SIMATIC HMI devices are also available for the
hazardous area "Zone 2/22" and can be found in the chapter
"Operator panels":
• SIMATIC HMI Comfort Panels

3

Siemens ST 80 / ST PC · 2013

3/25

© Siemens AG 2013

HMI devices for special requirements
HMI devices for hazardous areas
SIMATIC HMI Panel PC Ex

■ Overview
SIMATIC HMI Panel PC Ex with international approvals for
operation and monitoring in hazardous areas.

3
■ Technical specifications
HMI Panel PC Ex

6AV7200-1...

HMI Panel PC Ex

Design

Panel PC built-in unit, protective
enclosure available as an option

Front

15" and 19", optional 15"
sunlight-readable displays

Operation

Touch with 8 function keys

Processor

Intel Atom N270 with 1.6 GHz

Main memory

1 GB DDR2 SDRAM, 2 GB optional

Operating system,
preinstalled and configured

Windows XP Professional,
Windows XP Embedded,
Windows 7 MUI

Mass storage

CompactFlash 4 GB / 16 GB,
hard disk 100 GB

Power supply

24 V DC, max. 2.1 A (19")

Devices in version "Zone 1"
ATEX directive 94/9/EC
• Network 10/100 Base-Tx

• Network 10/100 Base-Fx

IECEx
• Network 10/100 Base-Tx
• Network 10/100 Base-Fx

Interfaces
Ethernet

10/100 Mbit Ex e, or fiber-optics
100 Mbit (SC) Ex op is

GOST-R
• Network 10/100 Base-Tx

USB 2.0

2 x Ex i, 2 x Ex e (Zone 1) or
2 x Ex nA (Zone 2)

• Network 10/100 Base-Fx

Serial

1 x RS232 or 1 x RS422/485

Ambient conditions

Ex d e ia ib mb [ia ib] IIC T4 Gb
Ex ia tb [ia ib] IIIC T80°C Db IP66
Ex d e ia ib mb [ia ib op is] IIC T4
Gb
Ex ia tb [ia ib op is] IIIC T80°C Db
IP66
2 Ex d e ia ib mb [iaib] IIC T4
DIP A21 TA80°C, IP66
2 Ex d e ia ib mb [iaibopis] IIC T4
DIP A21 TA80°C, IP66
Ex d e ia ib mb [ia ib] IIC T4 Gb,
Type 4X, IP66
Class II, Division 1, Groups E, F, G,
T80°C
Ex ia tb [ia ib] IIIC T80°C Db, IP66
Ex d e ia ib mb [ia ib] IIC T4
Ex ia tb [ia ib] IIIC T80°C Db IP66

IP66 at front, IP65 at rear,
IP66 in protective enclosure

Ambient temperature during operation

-20 °C ... +50 °C (cold start -10 °C)
with optional additional heating
down to -30 °C

KGS

Relative humidity during operation

90 % at + 40 °C, no condensation

InMetro
• Network 10/100 Base-Tx
• Network 10/100 Base-Fx

Device version "UL Class 1,
Division 2"

Siemens ST 80 / ST PC · 2013

II 2 (2) G Ex d e ia ib mb [ia ib] IIC
T4 Gb
II 2 (2) D Ex ia tb [ia ib] IIIC T80°C
Db IP66
II 2 (2) G Ex d e ia ib mb [ia ib op is]
IIC T4 Gb
II 2 (2) D Ex ia tb [ia ib op is] IIIC
T80°C Db IP66

CSA

Degree of protection

3/26

6AV7200-1...

Approvals/directives

General features

Ex d e ia ib mb [ia ib] IIC T4 Gb
Ex ia tb [ia ib] IIIC T80°C Db IP66
Ex d e ia ib mb [ia ib op is] IIC T4
Gb
Ex ia tb [ia ib op is] IIIC T80°C Db
IP66
Class 1, Division 2,
Groups A, B, C, D
Class 2, Division 2, Groups F, G
Class 3, Hazardous Locations

© Siemens AG 2013

HMI devices for special requirements
HMI devices for hazardous areas
SIMATIC HMI Panel PC Ex

■ Technical specifications (continued)
HMI Panel PC Ex

6AV7200-1...

Devices in version "Zone 2"
ATEX directive 94/9/EC
• Network 10/100 Base-Tx

• Network 10/100 Base-Fx

IECEx
• Network 10/100 Base-Tx

• Network 10/100 Base-Fx

GOST-R
• Network 10/100 Base-Tx
• Network 10/100 Base-Fx

CSA

InMetro
• Network 10/100 Base-Tx

• Network 10/100 Base-Fx

Device version "UL Class 1,
Division 2"

HMI Panel PC Ex

6AV7200-1...

Dimensions
II 3 (2/3) G Ex d e ia ib mb nA
[ib Gb] [ic] IIC T4 Gc
II3 (2/3) D Ex ia tc [ib Db] [ic] IIIC
T80°C Dc IP66
II 3 (2/3) G Ex d e ia ib mb nA
[ib op is Gb] [ic] IIC T4 Gc
II 3 (2/3) D Ex ia tc [ib op is Db]
[ic] IIIC T80°C Dc IP66

Mounting dimensions (W x H x D)

15":
427.5 mm x 327.5 mm x 165 mm
19":
522.5 mm x 412.5 mm x 165 mm

Front dimensions (W x H)

15": 440 mm x 340 mm
19": 535 mm x 425 mm

Weight

15": 15 kg
19": 23 kg

Ex d e ia ib mb nA [ib Gb] [ic]
IIC T4 Gc
Ex ia tc [ib Db] [ic] IIIC T80°C Dc
IP66
Ex d e ia ib mb nA [ib op is Gb
] [ic] IIC T4 Gc
Ex ia tc [ib op is Db] [ic] IIIC T80°C
Dc IP66

3

2 Ex d e ia ib mb nA [ib][ic] IIC T4
DIP A21 TA80°C, IP66
2 Ex d e ia ib mb nA [ib opis][ic] IIC
T4
DIP A21 TA80°C, IP66
Ex d e ia ib mb nA [ib Gb] [ic] IIC T4
Gc, Type 4X, IP66
Class II, Division 2, Groups E, F, G,
T80°C;
Ex ia tc [ib ic] IIIC T80°C Dc, IP66
Ex d e ia ib mb nA [ib Gb] [ic] IIC T4
Gc
Ex ia tc [ib Db] [ic] IIIC T80°C Dc
IP66
Ex d e ia ib mb nA [ib op is Gb] IIC
T4
Ex ia tc [ib op is Db] [ic] IIIC T80°C
Dc IP66
Class 1, Division 2,
Groups A, B, C, D
Class 2, Division 2, Groups F, G
Class 3, Hazardous Locations

Siemens ST 80 / ST PC · 2013

3/27

© Siemens AG 2013

HMI devices for special requirements
HMI devices for hazardous areas
SIMATIC HMI Panel PC Ex

■ Ordering data
SIMATIC HMI Panel PC Ex

3

Order No.

Order No.

6AV7200- 1 7 7 7 7 - 7 7 A 0

Design / display size
• Zone 2: 15" Touch
with function keys
• Zone 2: 19" Touch
with function keys
• Zone 1: 15" Touch
with function keys
• Zone 1: 19" Touch
with function keys
• UL Class 1, Division 2:
15" Touch with function keys
• UL Class 1, Division 2:
19" Touch with function keys
• Zone 2: 15" Touch, sunlight
readable with 8 function keys
• Zone 1: 15" Touch, sunlight
readable with 8 function keys
Communication interfaces
• 10/100 base Tx, Ex e
• 100 base Fx FOC (SC), Ex op is
Mass storage
• CF 4 GB, 1 GB RAM
• CF 16 GB, 1 GB RAM
• HDD 100 GB, 1 GB RAM
• CF 4 GB, 2 GB RAM
• CF 16 GB, 2 GB RAM
• HDD 100 GB, 2 GB RAM
Operating system (preinstalled)
• Windows XP Embedded on CF
(language package 1) 1)
• Windows XP Professional MUI
(only on HDD)
• Windows 7 Ultimate (only on HDD)
Enclosure options
(device is delivered already fitted)
• without
• Stainless steel enclosure for:
- Wall mounting
- Stand (incl. coupling,
300° rotation possible)
- Suspension bracket (incl.
coupling, 300° rotation possible)
- Support arm (incl. coupling,
300° rotation possible)
- Swivel arm from above (incl.
coupling, 300° rotation possible)

A
B
D
E

1)

G
H
J
K

A
B
1
2
3
4
5
6
1
3
4

0
2
3
4
5
6

A
B
C
D
E
F
G

-z
-z
-z
-z

A
B
C
D

0
0
0
0

1
1
1
1

Package 1: upon initial startup, select the language from: English, German,
French, Italian, Spanish, Portuguese, Brazilian, Dutch, Danish, Swedish,
Norwegian, Finnish, Greek, Hungarian, Czech, Polish, Turkish, Russian,
Hebrew, Arabic, Chinese, Japanese, Korean, Thai

3/28

Siemens ST 80 / ST PC · 2013

Digital KVM for HMI Thin Client Ex

6AV7675-0EX00-0AA0

USB drive
• Intrinsically-safe, 8 GB
• Intrinsically-safe,
8 GB with recovery function

6AV7675-0FX00-0AA0
6AV7675-0FX10-0AA0

Ethernet switch

6AV7675-0PX00-0AA0

with FOC 4 x 100 Base Tx,
1 x 100 Base (MTRJ) Fx Ex op is

External keyboard for stainless steel
enclosure (incl. keyboard enclosure)
• without
• QWERTZ keyboard
• QWERTY keyboard
• AZERTY keyboard
• QWERTZ keyboard with trackball
• QWERTY keyboard with trackball
• AZERTY keyboard with trackball
Further options together with
stainless steel enclosure
• Breather glands
• Heating (requires breather glands)
• Handles
• Front USB (at bottom)

Accessories

© Siemens AG 2013

HMI devices for special requirements
HMI devices for hazardous areas
SIMATIC HMI Panel PC Ex

■ Dimensional drawings
Legend:

i = Clamping frame

h = Mounting clamp (10 x)

j = Control cabinet or enclosure

All dimensions in mm. For mounting cut-out see technical specifications.

3

h
426

i

427.5+0.5

j

G_ST80_XX_00419

340

327.5+0.5

165

326

440

SIMATIC HMI Panel PC Ex 15"

h
521
522.5+0.5

i
j

G_ST80_XX_00420

412.5+0.5

165

411

425

535

SIMATIC HMI Panel PC Ex 19"

■ More information
Additional information is available on the Internet at:
http://www.siemens.com/simatic-hmi-ex

Siemens ST 80 / ST PC · 2013

3/29

© Siemens AG 2013

HMI devices for special requirements
HMI devices for hazardous areas
SIMATIC HMI Thin Client Ex

■ Overview

HMI Thin Client Ex
IECEx
• Network 10/100 Base-Tx
• Network 10/100 Base-Fx

GOST-R
• Network 10/100 Base-Tx
• Network 10/100 Base-Fx

3

6AV7200-0...

General features
Design

Thin Client built-in unit, available in
protective enclosure as an option

Front

15", 19", and 15" sunlight readable
display

Operation

Touch with 8 function keys

MTBF backlight

50 000 h

Operating system

Closed system on Windows XP
Embedded basis

Mass storage

Integrated

Power supply

24 V DC, max. 2.1 A (19")

KGS

Ex d e ia ib mb [ia ib] IIC T4
Ex ia tb [ia ib] IIIC T80°C Db IP66

• Network 10/100 Base-Fx

• Network 10/100 Base-Fx

IECEx
• Network 10/100 Base-Tx

• Network 10/100 Base-Fx

Ethernet

100 Mbit Ex e, or alternatively
fiber-optics 100 Mbit (SC) Ex op is

USB 2.0

2 x Ex i, 2 x Ex e (Zone 1) or
2 x Ex nA (Zone 2)

GOST-R
• Network 10/100 Base-Tx

Serial

1 x RS232 or 1 x RS422/485

• Network 10/100 Base-Fx

Degree of protection

IP66 at front, IP65 at rear, IP66 in
protective enclosure

CSA

Ambient temperature during operation

- 20 °C ... + 50 °C, cold start -10 °C,
with optional additional heating
down to -30 °C

Relative humidity during operation

90 % at 40 °C, no condensation

Ambient conditions

InMetro
• Network 10/100 Base-Tx

Devices in "Zone 1" version
ATEX directive 94/9/EC
• Network 10/100 Base-Tx

• Network 10/100 Base-Fx

II 2 (2) G Ex d e ia ib mb [ia ib] IIC
T4 Gb
II 2 (2) D Ex ia tb [ia ib] IIIC T80°C
Db IP66
II 2 (2) G Ex d e ia ib mb [ia ib op is]
IIC T4 Gb
II 2 (2) D Ex ia tb [ia ib op is] IIIC
T80°C Db IP66

Ex d e ia ib mb [ia ib] IIC T4 Gb
Ex ia tb [ia ib] IIIC T80°C Db IP66
Ex d e ia ib mb [ia ib op is] IIC T4
Gb
Ex ia tb [ia ib op is] IIIC T80°C Db
IP66

Devices in version "Zone 2"
ATEX directive 94/9/EC
• Network 10/100 Base-Tx

Interfaces

Approvals/directives

2 Ex d e ia ib mb [iaib] IIC T4
DIP A21 TA80°C, IP66
2 Ex d e ia ib mb [iaibopis] IIC T4
DIP A21 TA80°C, IP66
Ex d e ia ib mb [ia ib] IIC T4 Gb,
Type 4X, IP66
Class II, Division 1, Groups E, F, G,
T80°C
Ex ia tb [ia ib] IIIC T80°C Db, IP66

■ Technical specifications
HMI Thin Client Ex

Ex d e ia ib mb [ia ib] IIC T4 Gb
Ex ia tb [ia ib] IIIC T80°C Db IP66
Ex d e ia ib mb [ia ib op is] IIC T4
Gb
Ex ia tb [ia ib op is] IIIC T80°C Db
IP66

CSA

InMetro
• Network 10/100 Base-Tx

SIMATIC HMI Thin Client Ex with international approvals for
operation and monitoring in hazardous areas.

6AV7200-0...

• Network 10/100 Base-Fx

II 3 (2/3) G Ex d e ia ib mb nA [ib
Gb] [ic] IIC T4 Gc
II3 (2/3) D Ex ia tc [ib Db] [ic] IIIC
T80°C Dc IP66
II 3 (2/3) G Ex d e ia ib mb nA [ib op
is Gb] [ic] IIC T4 Gc
II 3 (2/3) D Ex ia tc [ib op is Db] [ic]
IIIC T80°C Dc IP66
Ex d e ia ib mb nA [ib Gb] [ic] IIC T4
Gc
Ex ia tc [ib Db] [ic] IIIC T80°C Dc
IP66
Ex d e ia ib mb nA [ib op is Gb] [ic]
IIC T4 Gc
Ex ia tc [ib op is Db] [ic] IIIC T80°C
Dc IP66
2 Ex de i a ib mb nA [ib][ic] IIC T4
DIP A21 TA80°C, IP66
2 Ex de i a ib mb nA [ibopis][ic] IIC
T4
DIP A21 TA80°C, IP66
Ex d e ia ib mb nA [ib Gb] [ic] IIC T4
Gc, Type 4X, IP66
Class II, Division 2, Groups E, F, G,
T80°C; Ex ia tc [ib ic] IIIC
T80°C Dc, IP66
Ex d e ia ib mb nA [ib Gb] [ic] IIC T4
Gc
Ex ia tc [ib Db] [ic] IIIC T80°C Dc
IP66
Ex d e ia ib mb nA [ib op is Gb] IIC
T4
Ex ia tc [ib op is Db] [ic] IIIC T80°C
Dc IP66

Protocols

RDP, RealVNC

Digital KVM switch

Input: DVI / VGA, PS/2 / USB,
output: RJ45 (IP network)

Dimensions

3/30

Siemens ST 80 / ST PC · 2013

Mounting dimensions
(W x H x D) in mm

15": 427.5 x 327.5 x 165
19": 522.5 x 412.5 x 165

Front dimensions in mm

15": 440 x 340
19": 535 x 425

Weight

15": 15 kg, 19": 23 kg

© Siemens AG 2013

HMI devices for special requirements
HMI devices for hazardous areas
SIMATIC HMI Thin Client Ex

■ Ordering data
SIMATIC HMI Thin Client Ex
Design / display size
• Zone 2: 15" Touch
with function keys
• Zone 2: 19" Touch
with function keys
• Zone 1: 15" Touch
with function keys
• Zone 1: 19" Touch
with function keys
• Zone 2: 15" Touch, sunlight
readable with function keys
• Zone 1: 15" Touch, sunlight
• readable with function keys
Communication interfaces
• 10/100 base Tx, Ex e
• 100 base Fx FOC (SC), Ex op is
Enclosure options
(device is delivered already fitted)
• without
• Stainless steel enclosure for:
- Wall mounting
- Stand (incl. coupling,
300° rotation possible)
- Suspension bracket (incl.
coupling, 300° rotation possible)
- Support arm (incl. coupling,
300° rotation possible)
- Swivel arm from above (incl.
coupling, 300° rotation possible)

Order No.
6AV7200-

Order No.
077 0 0-77A0
A
B
D
E

Digital KVM for HMI Thin Client Ex

6AV7675-0EX00-0AA0

USB drive
• Intrinsically-safe, 8 GB
• Intrinsically-safe,
8 GB with recovery function

6AV7675-0FX00-0AA0
6AV7675-0FX10-0AA0

Ethernet switch

6AV7675-0PX00-0AA0

With FOC 4 x 100 Base Tx,
1 x 100 Base (MTRJ) Fx Ex op is

G
H

A
B

3
0
2
3
4
5
6

External keyboard for enclosure
(incl. keyboard enclosure)
• without
• QWERTZ keyboard
• QWERTY keyboard
• AZERTY keyboard
• QWERTZ keyboard with trackball
• QWERTY keyboard with trackball
• AZERTY keyboard with trackball
Further options together with
stainless steel enclosure
• Breather glands
• Heating (requires breather glands)
• Handles
• Front USB (at bottom)

Accessories

A
B
C
D
E
F
G

-z
-z
-z
-z

A
B
C
D

0
0
0
0

1
1
1
1

Siemens ST 80 / ST PC · 2013

3/31

© Siemens AG 2013

HMI devices for special requirements
HMI devices for hazardous areas
SIMATIC HMI Thin Client Ex

■ Dimensional drawings
Legend:

i = Clamping frame

h = Mounting clamp (10 x)

j = Control cabinet or enclosure

All dimensions in mm. For mounting cut-out see technical specifications.

G_ST80_XX_00419

327.5+0.5

340

3

165

326

440

h
426

i

427.5+0.5

j

SIMATIC HMI Thin Client Ex 15"
15" touch front

Width in mm

Height in mm

Depth in mm

Operating unit

440

340

165

Installation cutout

427.5 ± 0.5

327.5 ± 0.5

-

G_ST80_XX_00420

412.5+0.5

165

411

425

535

h
521

i

522.5+0.5

j

SIMATIC HMI Thin Client Ex 19"
19" touch front

Width in mm

Height in mm

Depth in mm

Operating unit

535

425

165

Installation cutout

522 ± 0.5

412.5 ± 0.5

-

■ More information
Additional information is available on the Internet at:
http://www.siemens.com/simatic-hmi-ex

3/32

Siemens ST 80 / ST PC · 2013

4

© Siemens AG 2013

HMI Software
4/2

Introduction

4/5
4/6
4/12
4/14
4/19
4/25
4/31
4/32
4/34
4/36
4/37
4/38
4/42
4/44
4/47
4/50

HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal)
Engineering
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Advanced
WinCC Runtime Professional
WinCC Runtime Communication
SIMATIC WinCC (TIA Portal) options
WinCC Recipes
WinCC Logging
WinCC Audit
SIMATIC Logon
WinCC Sm@rtServer
WinCC Server / WinCC Client
WinCC WebNavigator
WinCC DataMonitor
WinCC ControlDevelopment

4/51
4/52
4/56

Software for energy management
SIMATIC B.Data
SIMATIC powerrate

4/59

SIMATIC WinCC flexible
HMI system
SIMATIC WinCC flexible ES
SIMATIC WinCC flexible RT
SIMATIC WinCC flexible options
WinCC flexible /ChangeControl
WinCC flexible /Archives
WinCC flexible /Recipes
WinCC flexible /Audit
SIMATIC Logon for WinCC flexible
WinCC flexible /Sm@rtAccess
WinCC flexible /Sm@rtService
WinCC flexible /OPC server
WinCC flexible /ProAgent

4/60
4/64
4/71
4/72
4/73
4/74
4/75
4/76
4/78
4/82
4/85
4/87

4/88
4/89
4/107
4/108
4/110
4/111
4/112
4/115
4/116
4/117
4/118
4/120
4/122
4/124
4/126
4/127
4/129
4/130
4/131
4/132
4/133
4/134
4/138
4/139

SCADA system SIMATIC WinCC
SIMATIC WinCC
SIMATIC WinCC options
SIMATIC BATCH for WinCC
SIMATIC Information Server
SIMATIC Logon
SIMATIC Maintenance Station
SIMATIC Process Historian
WinCC/Calendar Scheduler
WinCC/Central Archive Server (CAS)
WinCC/ChangeControl & WinCC/Audit
WinCC/Connectivity Pack &
WinCC Connectivity Station
WinCC/DataMonitor
WinCC/DowntimeMonitor
WinCC/Event Notifier
WinCC/IndustrialDataBridge
WinCC/IndustrialX
WinCC/Open Development Kit (ODK)
WinCC/ProAgent
WinCC/Redundancy
WinCC/Server
WinCC/TeleControl
WinCC/User Archives
WinCC/Web Navigator

4/144

WinCC add-ons and
partner management

4/146

SCADA System
SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture
Add-ons

4/155

4/161

SIMATIC ProAgent process
diagnostics software

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

HMI Software
Introduction
HMI software

■ Overview

Engineering
Software

WinCC Professional
WinCC Advanced
WinCC Comfort
WinCC Basic

Integrated runtime
module

Comfort Panels
Mobile Panels
x77 Panels and
Multi Panels

PC-based
single-user system,
e.g. SIMATIC IPC

PC-based multi-user system

Integrated runtime
module

WinCC Runtime
Advanced

WinCC Runtime Professional

SCADA functionality

G_ST80_XX_00461

Runtime Software
and target systems

Basic Panels

4
With the product families SIMATIC WinCC (TIA Portal),
SIMATIC WinCC flexible, SIMATIC WinCC and SIMATIC WinCC
Open Architecture, SIMATIC HMI offers visualization and configuration software for the entire HMI spectrum:
• SIMATIC WinCC (TIA Portal)
Creation of applications in the machine-level area and of
process visualization or SCADA systems
• SIMATIC WinCC flexible
Creation of applications in the machine-level area:
• SIMATIC WinCC
Creation of process visualization or SCADA systems
• SIMATIC WinCC Open Architecture
Creation of applications with a high demand for customerspecific adaptations, large and/or complex applications, as
well as projects that demand special system requirements
and functions.

SIMATIC WinCC (TIA Portal)
WinCC (TIA Portal) is based on the new central engineering
framework Totally Integrated Automation Portal (TIA Portal),
which provides users with an integrated, efficient and intuitive
solution to all automation tasks. SIMATIC WinCC (TIA Portal)
covers applications in the machine-level area and applications
in the process visualization or SCADA environment. WinCC
(TIA Portal) offers the uniform and scalable configuration tools
WinCC Basic, Comfort, Advanced and Professional for configuring the current SIMATIC HMI devices:
• SIMATIC Basic Panels
• SIMATIC Comfort Panels
• SIMATIC Mobile Panels
• SIMATIC Panels 77/177/277 series
• SIMATIC Multi Panels of the 177/277/377 series
• PC-based systems
- SIMATIC WinCC Runtime Advanced
- SIMATIC WinCC Runtime Professional
In addition, WinCC (TIA Portal) offers:
• Intuitive user interface with maximum degree of operator
friendliness
• Clear configuration of devices and network topologies
• Shared data management and uniform symbols via controller
and HMI
• Optimum interaction with the controller and HMI in a working
environment
• Powerful editors for efficient engineering
• Integrated mass data operations for efficient configuration
• System diagnostics as an integral component
• Comprehensive library concept

4/2

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

HMI Software
Introduction
HMI software

■ Overview (continued)
SIMATIC WinCC flexible

SIMATIC WinCC

Covers applications in the machine-level area. WinCC flexible
offers the integrated and scalable configuration tools
WinCC flexible Micro, Compact, Standard and Advanced for
configuring SIMATIC HMI devices:
• SIMATIC Basic Panels
• SIMATIC Mobile Panels
• SIMATIC Micro Panels
• SIMATIC Panels of the 70/170/270 series as well as C7-635
and C7-636
• SIMATIC Multi Panels of the 170/270/370 series
• PC-based systems
- SIMATIC WinCC flexible Runtime
• Runs under Windows XP Professional /
Windows 7 Professional, Ultimate, Enterprise
• Expanded integration into STEP 7 and SIMOTION
• Optionally expandable with functions for version administration and logging changes (WinCC flexible /ChangeControl)
• Modular PC-based HMI solution for single-user systems
directly at the machine level
• Basic package for visualization, reporting and logging; can be
expanded by implementing option packages
• Flexible expansion possible with VB scripts and customized
ActiveX controls created with OPP (Open Platform Program)

The process visualization or SCADA system for visualizing and
operating processes, production flows, machines and plants in
all sectors – from the simple single-user station through to
distributed multi-user systems with redundant servers and
cross-location solutions with web clients. WinCC is the information hub for company-wide, vertical integration (process
visualization and platform for IT & business integration).
• For universal use thanks to solutions for all sectors, e.g.
conforming to FDA 21 CFR Part 11, and multiple languages for
worldwide use
• All HMI functions on-board with industry-standard functions
for signaling and acknowledging events, archiving of
messages and measured values, logging of all process and
configuration data, user administration and visualization
(WinCC basic software).
• Company-wide, flexible client/server structures with operator
stations on the Web, distributed servers and data integrity
thanks to redundancy
• Easy to integrate over standard interfaces such as
OPC (OLE for Process Control), WinCC OLE-DB,
VBA (Visual Basic for Applications), VB script, C-API (ODK)
• Integration platform in the company thanks to the Historian
functionality integrated into WinCC based on the Microsoft
SQL Server, standard and programming interfaces and tools
and clients for evaluation
• Modular expansion with options and add-ons as well as
individual functional expansions with VB Script, Visual Basic
for Applications, C-API (ODK) and integration of ActiveX
elements.
• Object-orientation supports efficient engineering and flexible
plant expansion
• For large, distributed systems with up to 2048 servers
• Scalable – from a small single-user system up to a networked,
redundant high-end system
• WinCC OA can be used on any platform and is available for
Windows, Linux and Solaris
• Hot-standby redundancy and disaster recovery system
assure maximum fail-safety and availability
• WinCC OA offers a platform for customer-specific solutions
• Extensive driver and interfacing options: S7, SINAUT, OPC,
OPC UA, Modbus, IEC 60870-5-101/104, DNP3, BACnet, and
many others.
• Flexible logging of data either in file-based value archive or in
a relational database (ORACLE)
• Modular expansion is possible using options and add-ons as
well as individual functional expansions by means of own
script language CONTROL, API(C++) and integration of
ActiveX elements

Siemens ST 80 / ST PC · 2013

4/3

4

© Siemens AG 2013

HMI Software
Introduction
HMI software

■ Overview (continued)
SIMATIC WinCC Open Architecture
The SCADA system SIMATIC WinCC Open Architecture
addresses applications with high demand for customer-specific
adaptations, large and/or complex applications, as well as
projects that demand special system requirements and
functions.
SIMATIC WinCC Open Architecture demonstrates its high
performance in networked and redundant high-end control
systems in particular. From the field level to the control station,
from the machine to the company headquarters – integrated,
high-performance communication is ensured. In every situation,
a high level of availability, reliable information, fast interaction
and user friendliness are guaranteed. Applications can also be
changed without interrupting the process. Profitability, efficiency
and safety are therefore always in equilibrium.
With its disaster recovery system and SIL3 certification, SIMATIC
WinCC Open Architecture demonstrates its reliability in a wide
range of critical applications.

4

4/4

Siemens ST 80 / ST PC · 2013

SIMATIC WinCC Open Architecture is open for independent inhouse developments, which means that ideas can be turned into
new applications quickly and easily.
• Object-orientation supports efficient engineering and flexible
plant expansion
• For large, distributed systems with up to 2048 servers
• Scalable – from a small single-user system up to a networked,
redundant high-end system
• WinCC OA can be used on any platform and is available for
Windows, Linux and Solaris
• Hot-standby redundancy and disaster recovery system
assure maximum fail-safety and availability
• WinCC OA offers a platform for customer-specific solutions
• Extensive driver and interfacing options: S7, SINAUT, OPC,
OPC UA, Modbus, IEC 60870-5-101/104, DNP3, BACnet, and
many others.
• Flexible logging of data either in file-based value archive or in
a relational database (ORACLE)
• Modular expansion is possible using options and add-ons as
well as individual functional expansions by means of own
script language CONTROL, API(C++) and integration of
ActiveX elements

© Siemens AG 2013

HMI Software
HMI Software in the TIA Portal
HMI Software in the TIA Portal

■ Overview
SIMATIC WinCC (TIA Portal) engineering software
• Family of configuration systems with WinCC Basic, Comfort,
Advanced and Professional for SIMATIC operator panels, as
well as for the PC-based visualization systems WinCC
Runtime Advanced and WinCC Runtime Professional
SIMATIC WinCC Runtime Advanced visualization software
• PC-based HMI solution for single-user systems directly at the
machine
• Basic package for visualization, reporting and logging, user
administration, can be expanded flexibly with VB scripts
• Basic package expandable by means of option packages
• Integration of customer-specific ActiveX Controls created with
WinCC ControlDevelopment
• Can be integrated into automation solutions based on TCP/IP
networks
• Expanded service concepts with remote operation,
diagnostics and administration over the Intranet and Internet
in combination with e-mail communication

SIMATIC WinCC Runtime Professional visualization
software
• PC-based operator control and monitoring system for visualization and operator control of processes, production flows,
machines and plants in all sectors – from the simple singleuser station through to distributed multi-user systems and
cross-location solutions with web clients. WinCC Runtime
Professional is the information hub for corporation-wide
vertical integration.
• Industry-standard functions for signaling and acknowledging
events, archiving of messages and measured values, logging
of all process and configuration data, user administration, can
be expanded flexibly with VB and C scripts
• Basic package expandable by means of option packages
• Also included are APIs for the Runtime to utilize the open
programming interfaces
• Integration of customer-specific ActiveX Controls created with
WinCC ControlDevelopment

4

Siemens ST 80 / ST PC · 2013

4/5

© Siemens AG 2013

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Engineering

■ Overview

■ Application

• Integrated family of engineering tools for configuring
SIMATIC HMI operator panels, as well as for the PC-based
visualization systems WinCC Runtime Advanced and
WinCC Runtime Professional.
• WinCC (TIA Portal) is based on the new central engineering
framework Totally Integrated Automation Portal (TIA Portal),
which offers the user a uniform, efficient and intuitive solution
to all automation tasks.
• WinCC (TIA Portal) also offers uniform engineering from the
Basic Panel through to the SCADA application.
• Together with the STEP 7 (TIA Portal) products, WinCC
(TIA Portal) forms the optimum solution for integrated, efficient
engineering.
Current version:
• SIMATIC WinCC Basic V12 SP1
• SIMATIC WinCC Comfort V12 SP1
• SIMATIC WinCC Advanced V12 SP1
• SIMATIC WinCC Professional V12 SP1

■ Benefits

4

• The integrated configuration software reduces training,
maintenance and service overhead and protects the
customer's investments.
• Minimized engineering overhead and reduction of lifecycle
costs thanks to Totally Integrated Automation (TIA)
• Minimized configuration overhead due to reuse of scalable
and dynamizable objects
• Intelligent tools for efficient and simple configuration:
- Wizard for defining the basic structure of the HMI project
- Table-based editors simplify the generation and processing
of similar types of object, e.g. for tags, texts, or alarms.
- Complex configuration tasks such as the definition of paths
of motion or the creation of the fundamental operator
prompting are simplified by means of graphical configuration.
• Comprehensive support of multi-language configurations for
worldwide use
- Selectable views for entering configuration data in several
languages
- System and user-specific text lexicons
- Export/import of language-dependent texts
• Investment protection due to
- Import of the configuration from WinCC flexible 2008 SP2
and 2008 SP3
- Transfer of the configuration from WinCC V7.0 SP3

4/6

Siemens ST 80 / ST PC · 2013

SIMATIC WinCC in the editions Basic, Comfort, Advanced and
Professional are innovative engineering tools for configuring
SIMATIC HMI operator panels, as well as for the PC-based
visualization systems WinCC Runtime Advanced and WinCC
Runtime Professional.
Depending on the selected product, various target systems can
be configured:
WinCC Basic
• Basic Panels
WinCC Comfort
• As WinCC Basic, plus:
• Comfort Panels
• Mobile Panels: Mobile Panel 177, Mobile Panel 277
• Panels of the 70 series: OP 73, OP 77A, OP 77B
• Panels of the 170 series: TP 177A, TP 177B, OP 177B
• Panels of the 270 series: TP 277, OP 277
• Multi Panels: MP 177, MP 277, MP 377
WinCC Advanced
• As WinCC Comfort, plus:
• SIMATIC PCs with WinCC Runtime Advanced:
- SIMATIC Panel PC: IPC277D, Panel PC 477B, IPC477C,
IPC477D, Panel PC 577B, IPC577C, Panel PC 677B,
IPC677C
- SIMATIC Box PC: IPC227D, Box PC 427B, IPC427C,
IPC427D, Box PC 627B, IPC627C, Box PC 827B, IPC827C
- SIMATIC Rack PC: Rack PC 547B, IPC547C, IPC547D,
Rack PC 647B, IPC647C, Rack PC 847B, IPC847C
- SIMATIC modular Embedded Controller: EC31
• Standard PC with WinCC Runtime Advanced
• SINUMERIK PC: PCU 50.3, PCU 50.5
WinCC Professional
• As WinCC Advanced, plus:
• SIMATIC PCs with WinCC Runtime Professional:
- SIMATIC Panel PC: IPC477C, IPC477D, Panel PC 577B,
IPC577C, Panel PC 677B, IPC677C,
- SIMATIC Box PC: IPC427C, IPC427D, Box PC 627B,
IPC627C, IPC827C
- SIMATIC Rack PC: Rack PC 547B, IPC547C, IPC547D,
Rack PC 647B, IPC647C, Rack PC 847B, IPC847C
• Standard PC with WinCC Runtime Professional

© Siemens AG 2013

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Engineering

■ Design
The functionalities of the engineering tools of the SIMATIC
WinCC family are based on each other. The available editors are
largely determined by the respective configurable target
systems and their function. A more comprehensive engineering
tool such as WinCC Advanced can always be used to configure
lower-level target devices as well (e.g. Basic Panels)
A Powerpack can be used to upgrade from a smaller edition to
a larger one. This does not apply to WinCC Basic.
The functionality of WinCC engineering tools already contains
the configuration support of the available Runtime options for
SIMATIC Panels, WinCC Runtime Advanced or WinCC Runtime
Professional, irrespective of the purchased RT licenses.
A separate license is required for the target system when using
the configured Runtime options.

■ Function
Integration into automation systems
Integration into the SIMATIC Totally Integrated Automation Portal
(TIA Portal)
• Shared data management and uniform symbols via the
controller and HMI
• Optimum interaction between the controller and HMI in a
working environment
• System diagnostics as an integral component
• Shared use of communication settings and process point
definitions
• Simple dragging and dropping of tags from STEP 7 to an
HMI device, e.g. onto a screen
• Excellent support for the new SIMATIC S7-1500 controller
- With symbolic addressing
- Access to the new memory-optimized data blocks
- New alarm and diagnostics concept
Configuration interface
• Intuitive user interfaces with maximum degree of
user friendliness
• Comprehensive and fast access to editors and project data
• Adaptive user interface of engineering tools depending on
configured target system
• User-definable user interface settings, e.g. layout, toolbars
• Integrated mass data operations for efficient configuration

Project handling
• Device-independent configuration data can be used on a
variety of target systems without the need for conversion.
The interface adapts itself to the functional possibilities of the
target device.
• Cross-device utilization of common configuration data
(e.g. alarm classes, text library) in multi-device projects
• Wizard-assisted definition of basic structure of HMI projects
(e.g. display layout, operator prompting)
Screen editor with comprehensive options for efficient and
fast screen configuration
• Generation of interconnected screen objects via Drag&Drop,
e.g. tags for the creation of input/output fields with process
interfacing or buttons with screen selection function
• Definition of screen templates and functions
(comparable with the Slide Master in MS PowerPoint)
• User-friendly editor for the creation of faceplates with defined
external interface from screen objects
• Graphics-based configuration of motion paths
• Layer technology with up to 32 layers
• Tools for the Align, Rotate and Mirror functions
Import/export
• of tags, links, text lists, and alarms
Tabular editors
• Quick and easy generation and modification of configuration
objects of the same type, e.g. tags, texts or messages, in
tabular editors
• Intelligent default settings depending on previously
configured data, e.g. automatic incrementing of addresses
when generating consecutive tags
• Simple access to the properties of an object without superfluous user intervention
• Simultaneous modification of common object properties
Object-based data management with user-friendly search
and edit options
• Configuration of alarms and logs directly on the HMI tag,
no switching between different editors
• Cross-reference list with direct access to all objects,
e.g. for editing or selection
• Search for objects in entire project
• Text search and replace functions
Project documentation
• Selective project documentation, the following contents can
be printed:
- An entire project
- One or more project-associated devices
- Contents of an editor
- Libraries

Siemens ST 80 / ST PC · 2013

4/7

4

© Siemens AG 2013

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Engineering

■ Function (continued)
Libraries for predefined/user-defined configuration objects
• Storage of all configuration objects in the library, e.g. blocks
and even entire screens or tags
• Faceplates can be constructed from simple screen objects on
a customer-specific or project-specific basis. Changes to
these faceplates can be made centrally (block definition).
• A large number of scalable and dynamizable screen objects
is included in the scope of delivery
• Size-scalable graphics for industrial applications are included
in the scope of delivery
• Preview function for library objects

System prerequisites
WinCC engineering software
Processor type (min.)

Core i5; 2.4 GHz or comparable

RAM (min.)

3 GB (32-bit operating system)
8 GB (64-bit operating system)

Free hard disk space

2 GB on system drive "C:"

Operating systems

32-bit operating systems
• Windows XP Home SP3
(only WinCC Basic)
• Windows XP Professional SP3
• Windows 7 Home Premium SP1
(only WinCC Basic)
• Windows 7 Professional SP1
• Windows 7 Enterprise SP1
• Windows 7 Ultimate SP1
• Windows Server 2003 R2 Standard
Edition SP2
(only WinCC Advanced
and Professional)
• Windows Server 2008 Standard
Edition SP2
(only WinCC Advanced
and Professional)

Language support
• Multilingual project creation (max. 32 languages) in editors
thanks to selectable views
• Central management of language-specific texts and graphics
in libraries
• Edit, export and import of texts for translation
• Language-specific graphics

4

Visual Basic and C-Script Support
• IntelliSense function for fast programming of access to
runtime objects
• Simple creation of control sequences in script code
• Visual Basic Script debugging in simulator and
WinCC Runtime Advanced and WinCC Runtime Professional
Test and commissioning support
• Simulation of HMI projects on engineering PC
• Marking of incomplete or incorrect configuration directly in the
respective editor
• Jump to error cause based on alarm messages in the
Compiler
Migration of existing HMI projects
• Data transfer in projects from WinCC flexible
• Data transfer in projects from WinCC

64-bit operating systems
• Windows 7 Home Premium SP1
(only WinCC Basic)
• Windows 7 Professional SP1
• Windows 7 Enterprise SP1
• Windows 7 Ultimate SP1
• Windows Server 2008 R2 Standard
Edition SP2
(only WinCC Advanced
and Professional)
Screen resolution

at least 1280 x 1024

Optical drive

DVD-ROM

Note:
Opening several instances of WinCC on your engineering PC at
the same time may result in more demanding hardware requirements.
In addition to WinCC, Windows also requires space on the hard
disk; e.g. free disk space should be available for the swap file.
The following formula has proven itself in the past: Size of swap
file = 3 x size of RAM.
For further information, refer to your Windows documentation

4/8

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Engineering

■ Ordering data

Order No.

WinCC Basic V12 SP1
Engineering software for the
configuration and simulation of
Basic Panels;
electronic documentation in English,
French, German, Italian, Spanish,
simplified Chinese, traditional Chinese
• Software and documentation on
DVD, floating license, license key
on USB stick
• New type of delivery:
Online software delivery 1),
floating license, software
and license key download,
e-mail address required for the
delivery

6AV2100-0AA02-0AA5

6AV2100-0AA02-0AH5

WinCC Comfort V12 SP1
Engineering software for the
configuration and simulation of
SIMATIC Panels;
electronic documentation in English,
French, German, Italian, Spanish,
simplified Chinese, traditional Chinese
• Software and documentation
on DVD, floating license,
license key on USB stick
• New type of delivery:
Online software delivery 1),
floating license, software
and license key download,
e-mail address required for the
delivery

Engineering software for the
configuration and simulation of
SIMATIC Panels;
WinCC Runtime Professional
(with max. 4096 PowerTags),
WinCC Runtime Advanced
electronic documentation in English,
French, German, Italian, Spanish,
simplified Chinese, traditional Chinese
• Software and documentation
on DVD, floating license,
license key on USB stick
• New type of delivery:
Online software delivery 1),
floating license, software
and license key download,
e-mail address required for the
delivery

6AV2103-0HA02-0AA5

6AV2103-0HA02-0AH5

WinCC Professional max.
PowerTags V12 SP1

6AV2101-0AA02-0AA5

6AV2101-0AA02-0AH5

WinCC Advanced V12 SP1
Engineering software for the
configuration and simulation of
SIMATIC Panels;
WinCC Runtime Advanced,
electronic documentation in English,
French, German, Italian, Spanish,
simplified Chinese, traditional Chinese
• Software and documentation on
DVD, floating license, license key
on USB stick
• New type of delivery:
Online software delivery 1),
floating license, software
and license key download,
e-mail address required for the
delivery

Order No.
WinCC Professional 4096
PowerTags V12 SP1

Engineering software for the
configuration and simulation of
SIMATIC Panels;
WinCC Runtime Professional
(unlimited PowerTags),
WinCC Runtime Advanced
electronic documentation in English,
French, German, Italian, Spanish,
simplified Chinese, traditional Chinese
• Software and documentation
on DVD, floating license,
license key on USB stick
• New type of delivery:
Online software delivery (OSD) 1),
floating license, software
and license key download,
e-mail address required for the
delivery

4
6AV2103-0XA02-0AA5

6AV2103-0XA02-0AH5

Trial licenses
6AV2102-0AA02-0AA5

6AV2102-0AA02-0AH5

on DVD, 21 day trial
• WinCC Basic V12 SP1
• WinCC Comfort/Advanced
V12 SP1
• WinCC Professional V12 SP1

6AV2100-0AA02-0AA7
6AV2102-0AA02-0AA7
6AV2103-0AA02-0AA7

WinCC Professional 512
PowerTags V12 SP1
Engineering software for the
configuration and simulation of
SIMATIC Panels;
WinCC Runtime Professiona
l (with max. 512 PowerTags),
WinCC Runtime Advanced
electronic documentation in English,
French, German, Italian, Spanish,
simplified Chinese, traditional Chinese
• Software and documentation on
DVD, floating license,
license key on USB stick
• New type of delivery:
Online software delivery 1),
floating license, license key
download,
e-mail address required for the
delivery
1)

6AV2103-0DA02-0AA5

6AV2103-0DA02-0AH5

Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery

Siemens ST 80 / ST PC · 2013

4/9

© Siemens AG 2013

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Engineering

■ Ordering data

Order No.
Software Update Service

SIMATIC WinCC Engineering
System Powerpacks
(without version change)

For a period of 12 months and for a
fixed price, the customer is automatically provided with all upgrades
and service packs for each installed
WinCC engineering system or
option.

Floating license, license key
only on USB stick
• WinCC Basic to
WinCC Comfort V12 2)
• WinCC Comfort to
WinCC Advanced V12
• WinCC Advanced to WinCC
Professional 512 PowerTags V12
• WinCC Professional Powerpack
512 PowerTags to
4096 PowerTags V12
• WinCC Professional Powerpack
4096 PowerTags to max.
PowerTags V12

6AV2101-2AA02-0AC5
6AV2102-2AA02-0BD5
6AV2103-2AD02-0AC5
6AV2103-2DH02-0BD5

6AV2103-2HX02-0BD5

Online software delivery (OSD) 1)

4

Order No.

Powerpacks

Floating license, license key
download only
e-mail address required for the
delivery
• WinCC Basic to
WinCC Comfort V12 2)
• WinCC Comfort to
WinCC Advanced V12
• WinCC Advanced to WinCC
Professional 512 PowerTags V12
• WinCC Professional Powerpack
512 PowerTags to
4096 PowerTags V12
• WinCC Professional Powerpack
4096 PowerTags to max.
PowerTags

6AV2101-2AA02-0BJ5
6AV2102-2AA02-0BJ5
6AV2103-2AD02-0BJ5
6AV2103-2DH02-0BJ5

6AV2103-2HX02-0BJ5

The contract is automatically
extended by a further year unless
canceled at least 12 weeks prior to
expiration.
Software Update Service
(Standard Edition)
The delivery is implemented
according to the number of ordered
SUS products (e.g. 10 upgrade
packages with 10 DVDs, 10 USB
flash drives, etc.)
• WinCC Comfort
• WinCC Advanced
• WinCC Professional
512 PowerTags
• WinCC Professional
4096 PowerTags
• WinCC Professional
max. PowerTags

6AV6612-0AA00-0AL0
6AV6613-0AA00-0AL0
6AV2103-0DA00-0AL0
6AV2103-0HA00-0AL0
6AV2103-0XA00-0AL0

Software Update
Service (Compact Edition)
The delivery items are combined.
For several contracts, only 1 package with 1 data medium set, 1 USB
flash drive with the corresponding
number of licenses and the corresponding number of CoLs will be
supplied.
Delivery items to be combined must
be ordered as one item.
• WinCC Comfort
• WinCC Advanced
• WinCC Professional
512 PowerTags
• WinCC Professional
4096 PowerTags
• WinCC Professional
max. PowerTags

6AV6612-0AA00-0AM0
6AV6613-0AA00-0AM0
6AV2103-0DA00-0AM0
6AV2103-0HA00-0AM0
6AV2103-0XA00-0AM0

Online software delivery (OSD) 1)
Software Update Service
(Download)
All deliveries to be downloaded.
E-mail address required for the
delivery
• WinCC Comfort
• WinCC Advanced
• WinCC Professional
512 PowerTags
• WinCC Professional
4096 PowerTags
• WinCC Professional
max. PowerTags

4/10

Siemens ST 80 / ST PC · 2013

6AV6612-0AA00-0AY0
6AV6613-0AA00-0AY0
6AV2103-0DA00-0AY0
6AV2103-0HA00-0AY0
6AV2103-0XA00-0AY0

1)

Current information and availability regarding the new delivery package
can be found at:
http://www.siemens.com/tia-online-software-delivery

2)

Valid only for order numbers 6AV2100-0AA02-0AA5 and
6AV2100-0AA02-0AH5

© Siemens AG 2013

HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Engineering

■ Ordering data

Order No.

Order No.

Upgrades

Upgrades

WinCC V11 -> WinCC V12 SP1
Software and documentation
on DVD, upgrade license,
license key on USB stick
• SIMATIC WinCC Basic V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Comfort V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Advanced
V12 SP1 Upgrade V11 -> V12 SP1
• SIMATIC WinCC Professional
512 PowerTags V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Professional
4096 PowerTags V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Professional
max. PowerTags V12 SP1
Upgrade V11 -> V12 SP1

WinCC flexible 2008 ->
WinCC V12 SP1
Software and documentation
on DVD, upgrade license,
license key on USB stick
• WinCC flexible 2008 Compact to
WinCC Comfort V12 SP1
• WinCC flexible 2008 Standard to
WinCC Comfort V12 SP1
• WinCC flexible 2008 Advanced to
WinCC Advanced V12 SP1

6AV2101-4AB02-0AE5

Online software delivery (OSD) 1)
Upgrade license, software and
license key download,
e-mail address required for the
delivery
• WinCC flexible 2008 Compact to
WinCC Comfort V12 SP1
• WinCC flexible 2008 Standard to
WinCC Comfort V12 SP1
• WinCC flexible 2008 Advanced to
WinCC Advanced V12 SP1

6AV2101-4AB02-0AK5

Online software delivery (OSD) 1)
Floating license, software
and license key download
e-mail address required for the
delivery
• SIMATIC WinCC Basic V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Comfort V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Advanced
V12 SP1
Upgrade V11 -> V12 SP1

1)

6AV2100-3AA02-0AE5
6AV2101-3AA02-0AE5
6AV2102-3AA02-0AE5
6AV2103-3DA02-0AE5

6AV2103-3HA02-0AE5

6AV2103-3XA02-0AE5

6AV2100-3AA02-0AK5
6AV2101-3AA02-0AK5
6AV2102-3AA02-0AK5

WinCC V7 RC -> WinCC V12 SP1
Software and documentation
on DVD, upgrade license,
license key on USB stick
• Upgrade
SIMATIC WinCC V7.0 RC 128 ->
WinCC Professional
512 PowerTags V12 SP1 and
WinCC RT Professional
128 PowerTags
• Upgrade
SIMATIC WinCC V7.0 RC 512 ->
WinCC Professional
512 PowerTags V12 SP1 and
WinCC RT Professional
512 PowerTags
• Upgrade
SIMATIC WinCC V7.0 RC 2048 ->
WinCC Professional
4096 PowerTags V12 SP1 and
WinCC RT Professional
2048 PowerTags
• Upgrade
SIMATIC WinCC V7.0 RC 8192 ->
WinCC Professional
max. PowerTags V12 SP1 and
WinCC RT Professional
8192 PowerTags
• Upgrade
SIMATIC WinCC V7.0 RC 65536 ->
WinCC Professional
max. PowerTags V12 SP1 and
WinCC RT Professional
65536 PowerTags

6AV2101-4BB02-0AE5
6AV2102-4AA02-0AE5

6AV2101-4BB02-0AK5
6AV2102-4AA02-0AK5

4

6AV2103-4BD02-0AE5

6AV2103-4DD02-0AE5

6AV2103-4FH02-0AE5

6AV2103-4KX02-0AE5

6AV2103-4MX02-0AE5

Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery

■ More information
Further information can be found in the Internet at:
http://www.siemens.com/tia-portal

Siemens ST 80 / ST PC · 2013

4/11

© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) Runtime
SIMATIC WinCC (TIA Portal) Runtime

■ Overview
SIMATIC WinCC Runtime Professional
visualization software
• PC-based operator control and monitoring system for visualization and operator control of processes, production flows,
machines and plants in all sectors – from the simple singleuser station through to distributed multi-user systems and
cross-location solutions with web clients. WinCC Runtime
Professional is the information hub for corporation-wide
vertical integration.
• Industry-standard functions for signaling and acknowledging
events, archiving of messages and measured values, logging
of all process and configuration data, user administration, can
be expanded flexibly with VB and C scripts
• Basic package expandable by means of option packages
• Also included are APIs for the Runtime to utilize the open
programming interfaces

4

SIMATIC WinCC Runtime Advanced
visualization software
• PC-based HMI solution for single-user systems directly at the
machine
• Basic package for visualization, reporting and logging, user
administration, can be expanded flexibly with VB scripts
• Basic package expandable by means of option packages
• Can be integrated into automation solutions based on
TCP/IP networks
• Expanded service concepts with remote operation,
diagnostics and administration over the intranet and Internet
in combination with email communication

4/12

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Advanced

■ Overview
PC-based HMI solution for single-user systems directly at the
machine. SIMATIC WinCC Runtime Advanced is configured with
the SIMATIC WinCC Advanced or SIMATIC WinCC Professional
configuration software.

■ Benefits
• Functions for all visualization tasks:
- Operator functions
- Graphics and trend displays
- Alarm logging
- Report system
- Archiving (option)
- Recipe management (option)
- Audit Trail (option)
• Flexible runtime functionality due to Visual Basic scripts
• Innovative service concepts with remote operation,
diagnostics and administration via intranet and Internet as
well as e-mail communication to increase availability (option)
• Support for simple distributed automation solutions based on
TCP/IP networks at the machine level (option)
• Part of the Totally Integrated Automation Portal
- Direct access to the tag and message configuration of the
SIMATIC controller
- Excellent support of the new SIMATIC S7-1500 controller
With symbolic addressing
Access to the new memory-optimized data blocks
New alarm and diagnostics concept
- Integrated diagnostic functions for increasing productivity

■ Application
SIMATIC WinCC Runtime Advanced is the high-performance
visualization software for simple, machine-oriented visualization
tasks. It can be used as a single-user solution for all automation
applications in production automation, process automation and
building services automation.
SIMATIC WinCC Runtime Advanced can be used in combination
with the following HMI devices:
• SIMATIC Panel PC: IPC277D, Panel PC 477B, HMI IPC477C,
IPC477D, Panel PC 577B, HMI IPC577C, Panel PC 677B,
HMI IPC677C
• SIMATIC Box PC: IPC227D, Box PC 427B, IPC427C,
IPC427D, Box PC 627B, IPC627C, Box PC 827B, IPC827C
• SIMATIC Rack PC: Rack PC 547B, IPC547C, IPC547D,
Rack PC 647B, IPC647C, Rack PC 847B, IPC847C
• SIMATIC modular Embedded Controller: EC31
• SINUMERIK PC: PCU 50.3, PCU 50.5
• Standard PCs with resolutions (W x H in pixels) of:
- 4:3 format: 640 x 480, 800 x 600, 1024 x 768, 1280 x 1024,
1600 x 1200
- Widescreen format: 800 x 480, 1280 x 800, 1366 x 768,
1440 x 900, 1680 x 1050, 1920 x 1080, 1920 x 1200,
1980 x 1080

4

Siemens ST 80 / ST PC · 2013

4/13

© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Advanced

■ Design
SIMATIC WinCC Runtime Advanced is available as a software
package with 128, 512, 2 048 or 4 096 PowerTags.
The term PowerTags is used to identify process variables and
area pointers that have a process link to the controller.
Variables without process link, constant limit values of variables,
and messages (up to 4 000 bit-triggered messages) are also
available for additional system performance.
The range of functions of WinCC Runtime Advanced includes
the centralized HMI components for visualizing and reporting,
and it can be expanded to suit requirements and costs by using
optional packages.
SIMATIC WinCC Runtime Advanced is configured with the
SIMATIC WinCC Advanced or SIMATIC WinCC Professional
configuration software.

■ Function
Visualization via Windows-compliant user interface

4

Made up of parameterizable screen objects and faceplates
created on a project-specific basis:
• Numeric and alphanumeric input/output fields
• Static text and graphic display plus vector graphics
• Dynamizable graphics from HMI symbol library
• Bar graph, trend curve graph with scroll and zoom function as
well as read line
• Signal-specific text and graphic lists
• Buttons and switches for operator-process communication
• Editing fields for process values (signals)
• Analog display, slider as example for further screen objects
• Project-specific faceplates created from basic objects of the
system
• Graphic displays for various standard graphic formats,
e.g. bitmaps, .jpg, .wmf

4/14

Siemens ST 80 / ST PC · 2013

Alarms and messages
• Discrete alarms and analog alarms as well as event-driven
Alarm-S/Alarm-D message procedure with SIMATIC S7
• The new alarm and diagnostics concept of the S7-1500
controller is also supported
• Freely-definable alarm classes for definition of acknowledgment response and display of alarm events
Logging of alarms and process values 1)
• Logging in files (e.g. CSV or TXT file) and Microsoft SQL
databases
• Online evaluation of process value and alarm logs
• Evaluation of process value and alarm logs using standard
Microsoft tools such as Excel
Recipes 1)
• Generation of data records for machine data or production
data
• Display or entry of data records via a configurable screen
object or via process screens distributed within the project
• Transmission of data records from or to the controller
• Import/export of data records from/to CSV files for further
processing with other tools (e.g. MS Excel)
1)

Option for SIMATIC WinCC Runtime Advanced, runtime licenses must be
purchased separately. For further information, refer to "WinCC options".

Documentation of process data, alarm events, and recipes
• Time or event-driven report output
• User-definable layout
Flexible expansion of integrated system function using
Visual Basic script
Language support for multilingual projects
• Up to 32 online languages
• Language-dependent texts and graphics
• Language selection during runtime

© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Advanced

■ Function (continued)
User-oriented access protection according to requirements of
regulated sectors
• Authentication with user ID and password
• User group-specific rights
• Central system-wide user administration based on
SIMATIC Logon1)
• Monitoring of changes by operators in runtime operation1)
• Recording of operator actions in an Audit Trail 1)
Onboard controller connection to many different controllers
• Communication via native drivers and standard OPC channel
• Simultaneous connection using several protocols: OPC Client
and SIMATIC HMI HTTP protocol are additive, i.e. they can be
used in conjunction with other controller connections
Open communication between HMI systems and with higherlevel systems
• OPC server
- Use of the visualization system as a data server
(OPC Server) for higher-level automation components,
e.g. control systems or systems in the office area
- OPC-DA-Server: tags, e.g. process values
• Communication between HMI systems is established on
the basis of Ethernet networks, or via the Intranet/Internet
- Read and write access to tags. The WinCC Runtime
Advanced or SIMATIC Panels provide other SIMATIC HMI
systems or office applications with data (variables)
• Sending of e-mails on demand or event-driven
- e.g. to maintenance personnel via SMTP server
(Simple Mail Transfer Protocol)
- The optional use of e-mail/SMS gateways enables access to
standard networks (external service provider required)
• System diagnostics via device-specific HTML pages;
the following functions are available:
- Starting and stopping the HMI runtime for maintenance
- Remote access to recipe data records, passwords and information specific to the HMI system
- Access to the HMI system files via a file explorer
- Download of configuration data via the Intranet/Internet
- Supplement with own HTML pages

WinCC Sm@rtServer
for the remote control via the Intranet and Internet 1)
• Display and control of process screens on remote PC or Panel
• A SIMATIC HMI system can be used to control or monitor
another system remotely; entry level for client/server configurations for distributed operator stations or for solutions with
head end or control room
WinCC ControlDevelopment
for extending the functionality by adding own Controls 1)
• Development of proprietary VB.net or C# Controls for
integration in SIMATIC WinCC Runtime Advanced
1)

Option for SIMATIC WinCC Runtime Advanced, runtime licenses must be
purchased separately. For further information, refer to "WinCC options".

System prerequisites
SIMATIC WinCC
Runtime Advanced
Processor type (min.) 1)

All processors of the SIMATIC IPC,
Pentium III or processor running at
500 MHz or comparable

RAM (min.) 2)

512 MB

Free hard disk space 3)

2 GB on system drive "C:"

Operating systems

32-bit operating systems
• Microsoft Windows XP Professional
SP3
• Windows Embedded Standard
2009 (for IPC / IPC2x7D,
HMI IPC4x7C only)
• Microsoft Windows Server 2003 R2
StdE SP2
• Microsoft Windows Server 2008
StdE SP2
• Microsoft Windows 7 Professional
SP1
• Microsoft Windows 7 Enterprise
SP1
• Microsoft Windows 7 Ultimate SP1
• Microsoft Windows Embedded
Standard 7 SP1 (for IPC / IPC2x7D,
HMI IPC4x7C only)
64-bit operating systems
• Microsoft Windows 7 Professional
SP1
• Microsoft Windows 7 Enterprise
SP1
• Microsoft Windows 7 Ultimate SP1
• Microsoft Windows Server 2003 R2
StdE SP2
• Microsoft Windows Server 2008 R2
Standard Edition SP1
DVD-ROM

Optical drive
1)

In combination with options, more powerful systems may be required

2)

The required RAM is determined primarily by the size of the graphics used.

3)

Without taking archives into account.

In addition to WinCC, Windows also requires space on the hard
disk; e.g. free disk space should be available for the swap file.
The following formula has proven itself in the past: Size of swap
file = 3 x size of RAM.
For further information, refer to your Windows documentation.

Siemens ST 80 / ST PC · 2013

4/15

4

© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Advanced

■ Technical specifications
The following tables of system limitations provide assistance in
estimating whether a specific project is still within the system
limitations for WinCC Runtime Advanced.

Logs

The stated maximum values are not additive.

Number of logs

100

We cannot guarantee proper functioning of configurations that
make full use of all system limits on the HMI devices.

Number of entries per log
(including all log segments) 3)

500 000

In addition to the limitations specified, allowances must be
made for restrictions in configuration memory resources.

Number of log segments

400

Cyclical trigger for tag logging

1s

Number of tags that can be logged
per log

6 144

SIMATIC WinCC
Runtime Advanced

Trends

Tags
Number of tags in the project

6 144

Number of PowerTags

128 –4 096

Number of elements per array

1 600

Number of local tags

2 048

Alarms

4

SIMATIC WinCC
Runtime Advanced

Number of trends

800

Text lists and graphics lists
Number of graphic lists

500

Number of text lists

500

Number of entries per text or
graphic list

3 500

Number of alarm classes

32

Number of graphic objects

2 000

Number of discrete alarms

4 000

Number of text elements

30 000

Number of analog alarms

500

Scripts

Length of an alarm in characters

80

Number of scripts

Number of process values per alarm

8

Communication

Size of the alarm buffer

1 024

Number of connections

8

Number of queued alarm events

500

Number of connections based on
"SIMATIC HMI HTTP"

16

Number of screens

500

4 4)

Number of fields per screen

400

Maximum number of connected
Sm@rtClients (including a service
client)

Number of tags per screen

400

Help system

Number of complex objects per
screen1)

40

Number of characters in a help text

Screens

320

Languages

Recipes
Number of recipes

999

Number of elements per recipe 2)

2 000

User data length in KB per data
record

256

Number of data records per recipe

5 000

4/16

200

Siemens ST 80 / ST PC · 2013

Number of runtime languages

32

Scheduler
Time-triggered tasks 5)

48

User administration
Number of user groups

50

Number of user rights

32

Number of users

100

1)

Complex objects are: Bars, sliders, symbol library, clock, and all objects
from the Controls area.

2)

When using arrays, each array element represents a recipe element

3)

For the "segmented circular log" logging method, the number of entries for
all sequence logs is valid. The product derived from the number of circular
logs times the number of data records in this log may not be exceeded.

4)

Up to three Sm@rtClients can interconnect with the Sm@rtServer on
Panel PC 477.

5)

Event-triggered tasks are not relevant for the system limits.

© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Advanced

■ Ordering data

Order No.

Order No.

Basic Packages

Online software delivery (OSD) 2)

SIMATIC WinCC Runtime
Advanced V12 SP1

Single license, software and license
key download.
E-mail address required for the
delivery.
• WinCC Runtime Advanced
128 PowerTags to
WinCC Runtime Professional
128 PowerTags
• WinCC Runtime Advanced
512 PowerTags to
WinCC Runtime Professional
512 PowerTags
• WinCC Runtime Advanced
2048 PowerTags to
WinCC Runtime Professional
2048 PowerTags
• WinCC Runtime Advanced
4096 PowerTags to
WinCC Runtime Professional
4096 PowerTags

Software and documentation on
DVD, including options software 1)
Single license, license key on
USB stick
• 128 PowerTags
• 512 PowerTags
• 2048 PowerTags
• 4096 PowerTags

6AV2104-0BA02-0AA0
6AV2104-0DA02-0AA0
6AV2104-0FA02-0AA0
6AV2104-0HA02-0AA0

Online software delivery (OSD) 2)
Single license, software and license
key download.
E-mail address required for the
delivery.
• 128 PowerTags
• 512 PowerTags
• 2048 PowerTags
• 4096 PowerTags

6AV2104-0BA02-0AH0
6AV2104-0DA02-0AH0
6AV2104-0FA02-0AH0
6AV2104-0HA02-0AH0

Powerpacks
SIMATIC WinCC Runtime
Advanced V12
(without version change)
Single license, license key only
on USB stick for PowerTags from
• 128 PowerTags to 512 PowerTags
• 512 PowerTags to 2048 PowerTags
• 2048 PowerTags to
4096 PowerTags

6AV2104-2BD02-0BD0
6AV2104-2DF02-0BD0
6AV2104-2FH02-0BD0

Online software delivery (OSD) 2)
Single license, software and license
key download.
E-mail address required for the
delivery.
• 128 PowerTags to 512 PowerTags
• 512 PowerTags to 2048 PowerTags
• 2048 PowerTags to
4096 PowerTags

6AV2104-2BD02-0BJ0
6AV2104-2DF02-0BJ0
6AV2104-2FH02-0BJ0

6AV2105-2DD02-0AJ0

6AV2105-2FF02-0AJ0

6AV2105-2HH02-0AJ0

6AV2105-2BB12-0AC0

4

6AV2105-2DD12-0AC0

6AV2105-2FF12-0AC0

6AV2105-2HH12-0AC0

Upgrades

SIMATIC WinCC Runtime
Advanced V12 to
SIMATIC WinCC Runtime
Professional V12 SP1
Single license, software and documentation on DVD, license key on
USB stick for PowerTags from
• WinCC Runtime Advanced
128 PowerTags to
WinCC Runtime Professional
128 PowerTags
• WinCC Runtime Advanced
512 PowerTags to
WinCC Runtime Professional
512 PowerTags
• WinCC Runtime Advanced
2048 PowerTags to
WinCC Runtime Professional
2048 PowerTags
• WinCC Runtime Advanced
4096 PowerTags to
WinCC Runtime Professional
4096 PowerTags

SIMATIC WinCC Runtime
Advanced to
SIMATIC WinCC Runtime
Professional ASIA V12 SP1
• SIMATIC WinCC Runtime
Professional Powerpack Runtime
Advanced 128 PowerTags
-> Runtime Professional
128 PowerTags ASIA V12 SP1
• SIMATIC WinCC Runtime
Professional Powerpack Runtime
Advanced 512 PowerTags
-> Runtime Professional
512 PowerTags ASIA V12 SP1
• SIMATIC WinCC Runtime
Professional Powerpack Runtime
Advanced 2048 PowerTags
-> Runtime Professional
2048 PowerTags ASIA V12 SP1
• SIMATIC WinCC Runtime
Professional Powerpack Runtime
Advanced 4096 PowerTags
-> Runtime Professional
4096 PowerTags ASIA V12 SP1

6AV2105-2BB02-0AJ0

WinCC V11 to WinCC V12 SP1
SIMATIC WinCC Runtime
Advanced V11 to
SIMATIC WinCC Runtime
Advanced V12 SP1
6AV2105-2BB02-0AC0

6AV2105-2DD02-0AC0

6AV2105-2FF02-0AC0

6AV2105-2HH02-0AC0

Software and documentation on
DVD, including options software
Single license, license keys on
USB stick for
• SIMATIC WinCC Runtime
Advanced 128 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Runtime
Advanced 512 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Runtime
Advanced 2048 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Runtime
Advanced 4096 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1

6AV2104-3BB02-0AE0

6AV2104-3DD02-0AE0

6AV2104-3FF02-0AE0

6AV2104-3HH02-0AE0

1)

Runtime licenses for WinCC flexible Runtime Advanced options must
be purchased separately for each target system

2)

Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery

Siemens ST 80 / ST PC · 2013

4/17

© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Advanced

■ Ordering data

Order No.

Online software delivery (OSD) 2)
Single license, software and
license key download.
E-mail address required for the
delivery.
• SIMATIC WinCC Runtime
Advanced 128 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Runtime
Advanced 512 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Runtime
Advanced 2048 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Runtime
Advanced 4096 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1

6AV2104-3BB02-0AK0

6AV2104-3DD02-0AK0

6AV2104-3FF02-0AK0

6AV2104-3HH02-0AK0

SIMATIC WinCC flexible 2008
to SIMATIC WinCC Runtime
Advanced V12 SP1

4

6AV2107-4XP00-0BF0

Online software delivery (OSD) 2)

Upgrades WinCC flexible 2008
to WinCC V12 SP1

Software and documentation on
DVD, including options software
single license, license keys on
USB stick for
• WinCC flexible 2008 Runtime
128 PowerTags to
WinCC Runtime Advanced
128 PowerTags 1)
• WinCC flexible 2008 Runtime
512 PowerTags to
WinCC Runtime Advanced
512 PowerTags 1)
• WinCC flexible 2008 Runtime
2048 PowerTags to
WinCC Runtime Advanced
2048 PowerTags 1)
• WinCC flexible 2008 Runtime
4096 PowerTags to
WinCC Runtime Advanced
4096 PowerTags 1)

Order No.
SIMATIC WinCC flexible Panel
Options to
SIMATIC WinCC V11 / V12
Panel Options
• WinCC flexible /Audit
for SIMATIC Panels to
SIMATIC WinCC Audit for
SIMATIC Panels
• WinCC flexible /Sm@rtAccess
for SIMATIC Panel to
SIMATIC WinCC Sm@rtServer
for SIMATIC Panels
• WinCC flexible /Sm@rtService
for SIMATIC Panels to
SIMATIC WinCC Sm@rtServer
for SIMATIC Panels

6AV2104-4BB02-0AE0

6AV2104-4DD02-0AE0

Single license, license key
download only.
E-mail address required for
the delivery.
SIMATIC WinCC flexible Panel
Options to SIMATIC WinCC
V11 / V12 Panel Options
• WinCC flexible /Audit for
SIMATIC Panels to
SIMATIC WinCC Audit for
SIMATIC Panels
• WinCC flexible /Sm@rtAccess
for SIMATIC Panel to
SIMATIC WinCC Sm@rtServer
for SIMATIC Panels
• WinCC flexible /Sm@rtService
for SIMATIC Panels to
SIMATIC WinCC Sm@rtServer
for SIMATIC Panels

6AV2107-4XP00-0BK0

6AV2104-4FF02-0AE0

6AV2104-4HH02-0AE0

Online software delivery (OSD) 2)
Single license, software and license
key download.
E-mail address required for the
delivery.
• WinCC flexible 2008 Runtime
128 PowerTags to
WinCC Runtime Advanced
128 PowerTags 1)
• WinCC flexible 2008 Runtime
512 PowerTags to
WinCC Runtime Advanced
512 PowerTags 1)
• WinCC flexible 2008 Runtime
2048 PowerTags to
WinCC Runtime Advanced
2048 PowerTags 1)
• WinCC flexible 2008 Runtime
4096 PowerTags to
WinCC Runtime Advanced
4096 PowerTags 1)

6AV2104-4BB02-0AK0

6AV2104-4DD02-0AK0

6AV2104-4FF02-0AK0

6AV2104-4HH02-0AK0

■ More information
Further information can be found in the Internet at:
http://www.siemens.com/tia-portal

4/18

Siemens ST 80 / ST PC · 2013

1)

Each including 1 upgrade license to the WinCC Runtime Advanced
options

2)

Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery

© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Professional

■ Overview
PC-based operator control and monitoring system for visualization and operator control of processes, production flows,
machines and plants in all sectors – from the simple single-user
station through to distributed multi-user systems and crosslocation solutions with web clients.
SIMATIC WinCC Runtime Professional is the information hub for
corporation-wide vertical integration. SIMATIC WinCC Runtime
Professional is configured with the SIMATIC WinCC Professional
configuration software.

■ Benefits
• Functions for all visualization tasks:
- Operator functions
- Graphics and trend displays
- Alarm logging
- Report system
- Archiving (option)
- Recipe management (option)
• Universally scalable
- Expandable from single station to client-server configurations
- Process visualization via the web with the
WinCC WebNavigator
• Open standards for easy integration
- Efficient real-time database MS SQL Server
- Open for application modules with ActiveX controls
- Visual Basic for Applications for individual expansions
- OPC for cross-vendor communication
• Part of the Totally Integrated Automation Portal
- Direct access to the tag and message configuration of the
SIMATIC controller
- Excellent support of the new SIMATIC S7-1500 controller
With symbolic addressing
Access to the new memory-optimized data blocks
New alarm and diagnostics concept
- Integrated diagnostic functions for increasing productivity

■ Application
SIMATIC WinCC Runtime Professional is designed for visualization and operation of processes, manufacturing cycles,
machines and plants. With its powerful process interface,
especially to the SIMATIC family, and the secure data logging,
WinCC Runtime Professional enables solutions for the process
control.
The sector-neutral basic system enables universal usage in all
automation applications.
SIMATIC WinCC Runtime Professional can be used in combination with the following HMI devices:
SIMATIC PCs:
• SIMATIC Panel PC: HMI IPC477C, IPC477D, Panel PC 577B,
HMI IPC577C, Panel PC 677B, HMI IPC677C
• SIMATIC Box PC: IPC427C, IPC427D, Box PC 627B,
IPC627C, IPC827C
• SIMATIC Rack PC: Rack PC 547B, IPC547C, IPC547D,
Rack PC 647B, IPC647C, Rack PC 847B, IPC847C
• Standard PC

■ Design
SIMATIC WinCC Runtime Professional is available as a software
package with 128, 512, 2 048, 4 096, 8 192, 65 536 PowerTags.
PowerTags are data points that are connected to controllers or
other data sources via a WinCC Runtime Professional channel.
Up to 32 alarms can be obtained from one data point. Moreover,
internal tags without coupling are available for additional system
performance.
WinCC Runtime Professional also contains 500 archive tags.
Additional archive licenses can be obtained for greater quantity
structures.
Licenses for a multi-user configuration
The system software with the required number of PowerTags and
additionally the SIMATIC WinCC Server for Runtime Professional
option must be installed on the server. For the clients in the basic
configuration, a SIMATIC WinCC Client for Runtime Professional
license is sufficient.

■ Function
Visualization via Windows-compliant user interface
Made up of parameterizable screen objects and faceplates
created on a project-specific basis:
• Numeric and alphanumeric input/output fields
• Static text and graphic display plus vector graphics
• Dynamizable graphics from HMI symbol library
• Bar graph, trend curve graph with scroll and zoom function as
well as read line
• Signal-specific text and graphic lists
• Buttons and switches for operator-process communication
• Editing fields for process values (signals)
• Analog display, slider as example for further screen objects
• Project-specific faceplates created from basic objects of the
system
• Graphic displays for various standard graphic formats,
e.g. bitmaps, .jpg, .wmf
Alarms and messages
• Discrete alarms and analog alarms, as well as event-driven
Alarm-S/Alarm-D message procedure with SIMATIC S7
• The new alarm and diagnostics concept of the S7-1500
controller is also supported
• Freely-definable alarm classes for definition of acknowledgment response and display of alarm events
Logging of alarms and process values 1)
• Signaling system for detecting and archiving events with
display and control options according to DIN 19235
• Process logging for the acquisition, compression and storage
of measured values
• Online evaluation of process value and alarm logs
1)

Option for SIMATIC WinCC Runtime Professional; runtime licenses must be
purchased separately. For further information, refer to "WinCC options".

Siemens ST 80 / ST PC · 2013

4/19

4

© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Professional

■ Function (continued)
Recipes 1)
• Generation of data records for machine data or production
data
• Display or entry of data records via a configurable screen
object or via process screens distributed within the project
• Transmission of data records from or to the controller
• Import/export of data records for further processing with other
tools (e.g. MS Excel)
Documentation of process data, alarm events, and recipes
• Time or event-driven report output
• User-definable layout
Flexible expansion by means of Visual Basic Script and ANSI-C
• Programming interfaces for individual access to data and
functions of WinCC Runtime Professional and for the
integration in user programs with VBA, VB Script, C-API,
C-Script (ANSI-C)
Language support for multilingual projects
• Language-dependent texts and graphics
• Language selection during runtime

4

Onboard controller connection to many different controllers
• Communication via native drivers and standard OPC channel
• For communication with subordinate controls
(SIMATIC protocols, PROFIBUS DP, PROFIBUS FMS, DDE
and OPC server included in the scope of delivery)

Open communication between HMI systems and
with higher-level systems
• OPC-Server
Use of the visualization system as a data server (OPC-Server)
for higher-level automation components such as control
systems or systems in the office sector
- OPC-DA-Server: tags, e.g. process values
- OPC-HDA-Server: logged process values
- OPC-A&E-Server: Alarms
- OPC-XML-DA-Server: tags, e.g. process values
- OPC-UA-DA-Server: tags, e.g. process values
• OLE DB Server
- Standardized and user-friendly access to WinCC log data
(MS SQL Server 2005).
- Access is via the OLE-DB Provider supplies all WinCC log
data available along with the accompanying process values,
as well as alarm and user texts.
- The WinCC OLE-DB provider also supports analysis
functions such as minimum, maximum, alarm hit list, etc.
• WinCC WebNavigator for Runtime Professional 1)
- Option for SIMATIC WinCC Runtime Professional for
operating and monitoring plants over the Internet, company
Intranet or LAN.
- Configuration from a web server with the SIMATIC WinCC
Runtime Professional software as a single-user, client or
server version and a web client that enables operator control
and monitoring of a current WinCC Runtime Professional
project via an Internet browser with ActiveX support. The
WinCC basic system does not have to be installed on the
client computer.
• WinCC DataMonitor for Runtime Professional 1)
- The WinCC DataMonitor is used for displaying and evaluating current process states and historical data on office PCs
using standard tools such as Microsoft Internet Explorer or
Microsoft Excel.
The DataMonitor Client is supported by a web server with
current and historic process data and alarms. All staff
ranging from machine operators to corporate managers can
use the DataMonitor to obtain information.
1)

4/20

Siemens ST 80 / ST PC · 2013

Option for SIMATIC WinCC Runtime Professional; runtime licenses must be
purchased separately. For further information, refer to "WinCC options".

© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Professional

■ Function (continued)

■ Integration

WinCC ControlDevelopment
for extending the functionality by adding own Controls 1)
• Development of proprietary VB.net or C# Controls for
integration in WinCC Runtime Professional
1)

Option for SIMATIC WinCC Runtime Professional; runtime licenses must be
purchased separately. For further information, refer to "WinCC options".

System prerequisites

SIMATIC WinCC
Runtime Professional

Processor type (min.) 1)

• Windows XP: 2.5 GHz P4 or
comparable, Pentium M, 1.6 GHz
or comparable
• Windows 7 (32-bit): 3.5 GHz P4
or comparable, dual core
• Windows Server 2003: 3 GHz P4
or comparable
• Windows Server 2008: 3 GHz P4
or comparable, dual/multi core

RAM (min.) 2)

2 GB

Free hard disk space 3)

2 GB on system drive "C:"

Operating systems

32-bit operating systems
• Microsoft Windows XP Professional
SP3
• Windows Embedded Standard
2009 (for IPC / IPC2x7D, HMI
IPC4x7C only)
• Microsoft Windows Server 2003 R2
StdE SP2
• Microsoft Windows Server 2008
StdE SP2
• Microsoft Windows 7 Professional
SP1
• Microsoft Windows 7 Enterprise
SP1
• Microsoft Windows 7 Ultimate SP1
• Microsoft Windows Embedded
Standard 7 SP1 (for IPC / IPC2x7D,
HMI IPC4x7C only)

Integration in company-wide solutions
(IT and business integration)
WinCC Runtime Professional is strictly based on Microsoft
technology, which provides for the greatest possible compatibility and integration ability. ActiveX and .net Controls support
technology and sector-specific expansions.
Cross-manufacturer communication is also a simply exercise.
The reason: WinCC Runtime Professional can be used as an
OPC client and server, and in addition to access to current
process values, it also supports standards such as OPC HDA
(Historical Data Access), OPC Alarm & Events, OPC UA Data
Access and OPC XML Data Access. Just as important: Visual
Basic Scripting (VBS) as an easy-to-learn, open Runtime
language. If desired, professional application developers can
also use ANSI-C.
WinCC Runtime Professional integrates a powerful and scalable
Historian function based on the Microsoft SQL Server in the
basic system.
Thus the user is given all possibilities: from high-performance
archiving of current process data, to long-term archiving with
high data compression, through to a central information
turntable in form of a company-wide Process Historian.
Open interfaces form the basis for an effective IT and business
integration.

64-bit operating systems
• Microsoft Windows 7 Professional
SP1
• Microsoft Windows 7 Enterprise
SP1
• Microsoft Windows 7 Ultimate SP1
• Microsoft Windows Server 2003 R2
StdE SP2
• Microsoft Windows Server 2008 R2
Standard Edition SP1
Graphics card

32 MB RAM, 24 bit color depth

Network

Ethernet 10 Mbit/s or higher

Optical drive

DVD-ROM

1)

In combination with options, more powerful systems may be required

2)

The required RAM is determined primarily by the size of the graphics used.

3)

Without taking archives into account.

Note:
In addition to WinCC, Windows also requires space on the hard
disk; e.g. free disk space should be available for the swap file.
The following formula has proven itself in the past:
Size of swap file = 3 x size of RAM.
For further information, refer to your Windows documentation.

Siemens ST 80 / ST PC · 2013

4/21

4

© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Professional

■ Technical specifications
The following tables of system limits provide assistance in
estimating whether a specific project is still within the system
limitations for WinCC Runtime Professional. The stated maximum
values are not additive.
We cannot guarantee proper functioning of configurations that
make full use of all system limits on the HMI devices. In addition
to the limitations specified, allowances must be made for restrictions in configuration memory resources.
SIMATIC WinCC
Runtime Professional
Alarms

Logs
Trend views per screen

25

Trends per trend view

80

Tables per screen

25

Columns per table

12

Values per table

30 000

Logs per single-user station/server

100

Log tags per single-user station/
server 7)

8 000

Configurable alarms
per server/single user

20 000

PowerTags per alarm line

10

Trend views per image

25

User text blocks per alarm line

10

Trends per trend view

80

Alarm classes
(incl. system alarm classes)

18

User administration
Number of user groups

128

Alarm types

16

Number of user rights

999

Alarm priorities

17 (0...16)

Number of users

128

Alarms per alarm log

Unlimited 1)

Configurations – Quantity structure
in a multi-user system

Alarms per short-term log list

1 000

WinCC clients in a system

32 8) 9)

Alarms per long-term log list

1 000 2)

Web clients in a system

50 10)

Alarms per alarm display

5 000 3)

Trends

Alarms in Runtime

4

SIMATIC WinCC
Runtime Professional

Screens
Objects per screen 4)

3 0005)

Levels per screen

32

Screens per project

1 000 5)

Instances of fixed faceplates
in a process screen

31 instances of the same picture
type

Screen size in pixels

10 000 x 10 000

Nesting levels of screen objects

20

Recipes
000 5)

Number of recipes

1

Number of recipe elements

500 6)

Number of recipe data records

3 000 6)

Number of views

4/22

Unlimited

Siemens ST 80 / ST PC · 2013

5)

1)

Limited by system resources.

2)

On single-user station or server or on client per server if "LongTimeArchiveConsistency" is set to "No". On single-user station, server, or client if
"LongTimeArchiveConsistency" is set to "Yes".

3)

On single-user station or server or on client per server.

4)

The number and complexity of the objects affect the performance.

5)

Limited by system resources.

6)

The sum of the number of recipe elements and number of data records
must not exceed a value of 320,000.

7)

Dependent on the Logging Powerpack used for the log tags.
500 log tags are contained in the basis version.

8)

If the server is also used as an operating unit, the number of clients for this
server is reduced to four.

9)

Mixed configuration: 32 Clients + 3 Web Clients

10)

Mixed configuration: 50 Web Clients + 1 WinCC Client

© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Professional

■ Ordering data

Order No.

Order No.

Basic software

Powerpacks

SIMATIC WinCC
Runtime Professional V12 SP1

SIMATIC WinCC
Runtime Professional V12 and
SIMATIC WinCC
Runtime Professional ASIA V12

For PC systems;
incl. software options 1),
language/script versions:
DE, EN, FR, IT, ES
Single License, on DVD
incl. licensing, on USB stick, for:
• 128 PowerTags
• 512 PowerTags
• 2048 PowerTags
• 4096 PowerTags
• 8192 PowerTags
• 65535 PowerTags

6AV2105-0BA02-0AA0
6AV2105-0DA02-0AA0
6AV2105-0FA02-0AA0
6AV2105-0HA02-0AA0
6AV2105-0KA02-0AA0
6AV2105-0MA02-0AA0

Incl. 500 archive tags each
Online software delivery (OSD) 3)
Single license, software and
license key download.
E-mail address required
for the delivery.
• 128 PowerTags
• 512 PowerTags
• 2048 PowerTags
• 4096 PowerTags
• 8192 PowerTags
• 65535 PowerTags

6AV2105-0BA02-0AH0
6AV2105-0DA02-0AH0
6AV2105-0FA02-0AH0
6AV2105-0HA02-0AH0
6AV2105-0KA02-0AH0
6AV2105-0MA02-0AH0

Incl. 500 archive tags each
SIMATIC WinCC
Runtime Professional ASIA
V12 SP1
For PC systems;
incl. software options 1),
language/script versions:
EN, CHs, CHt, KOR, JPN
Single License, on DVD
incl. licensing, for:
• 128 PowerTags
• 512 PowerTags
• 2048 PowerTags
• 4096 PowerTags
• 8192 PowerTags
• 65535 PowerTags

6AV2105-0BA12-0AA0
6AV2105-0DA12-0AA0
6AV2105-0FA12-0AA0
6AV2105-0HA12-0AA0
6AV2105-0KA12-0AA0
6AV2105-0MA12-0AA0

Incl. 500 archive tags each
SIMATIC WinCC Client for
Runtime Professional
• WinCC Client for
Runtime Professional
• WinCC Client for
Runtime Professional
(form of delivery OSD 3))
• WinCC Client for
Runtime Professional ASIA

6AV2107-0DB02-0AA0
6AV2107-0DB02-0AH0

6AV2107-0DB12-0AA0

1)

Runtime licenses for WinCC Runtime Professional options must be
purchased separately for each target system.

2)

Each including 1 upgrade license to the WinCC Runtime Professional
options.

3)

Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery

Single license, license key only on
USB sticks for PowerTags from
• 128 to 512 PowerTags
• 512 to 2048 PowerTags
• 2048 to 4096 PowerTags
• 4096 to 8192 PowerTags
• 8192 to 65536 PowerTags

6AV2105-2BD02-0BD0
6AV2105-2DF02-0BD0
6AV2105-2FH02-0BD0
6AV2105-2HK02-0BD0
6AV2105-2KM02-0BD0

Online software delivery (OSD) 3)
Single license, license key
download only.
E-mail address required
for the delivery.
• 128 to 512 PowerTags
• 512 to 2048 PowerTags
• 2048 to 4096 PowerTags
• 4096 to 8192 PowerTags
• 8192 to 65536 PowerTags

6AV2105-2BD02-0BJ0
6AV2105-2DF02-0BJ0
6AV2105-2FH02-0BJ0
6AV2105-2HK02-0BJ0
6AV2105-2KM02-0BJ0

Upgrades WinCC V11
to WinCC V12 SP1
SIMATIC WinCC
Runtime Professional V11 to
SIMATIC WinCC
Runtime Professional V12 SP1
and SIMATIC WinCC
Runtime Professional ASIA V11
to SIMATIC WinCC
Runtime Professional ASIA
V12 SP1
Single license, on DVD
incl. licensing on USB stick
• SIMATIC WinCC Runtime
Professional 128 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Runtime
Professional 512 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Runtime
Professional 2048 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Runtime
Professional 4096 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Runtime
Professional 8192 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Runtime
Professional 65536 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1

4

6AV2105-3BB02-0AE0

6AV2105-3DD02-0AE0

6AV2105-3FF02-0AE0

6AV2105-3HH02-0AE0

6AV2105-3KK02-0AE0

6AV2105-3MM02-0AE0

Siemens ST 80 / ST PC · 2013

4/23

© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Professional

■ Ordering data

4

Order No.

Order No.

Upgrades WinCC V11
to WinCC V12 SP1
(continued)

Upgrades WinCC V7
to WinCC V12 SP1
(continued)

Online software delivery (OSD) 2)

SIMATIC WinCC V7.0
to SIMATIC WinCC
Runtime Professional V12 SP1
and SIMATIC WinCC V7.0 ASIA
to SIMATIC WinCC
Runtime Professional ASIA
V12 SP1
• WinCC V7.0 Runtime
2048 PowerTags to
WinCC Runtime Professional
2048 PowerTags V12 SP1 1)
• WinCC V7.0 Runtime
8192 PowerTags to
WinCC Runtime Professional
8192 PowerTags V12 SP1 1)
• WinCC V7.0 Runtime
65536 PowerTags to
WinCC Runtime Professional
65536 PowerTags V12 SP1 1)
• WinCC V7.0 RC/RT128 / RC/RT
Client to WinCC Client for
Runtime Professional V12 SP1

Single license, software and
license key download.
E-mail address required
for the delivery.
• SIMATIC WinCC Runtime
Professional 128 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Runtime
Professional 512 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Runtime
Professional 2048 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Runtime
Professional 4096 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Runtime
Professional 8192 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
• SIMATIC WinCC Runtime
Professional 65536 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1

6AV2105-3BB02-0AK0

6AV2105-3DD02-0AK0

6AV2105-3FF02-0AK0

6AV2105-3HH02-0AK0

6AV2105-3KK02-0AK0

6AV2105-3MM02-0AK0

Upgrades WinCC V7
to WinCC V12 SP1
SIMATIC WinCC V7.0
to SIMATIC WinCC
Runtime Professional V12 SP1
and SIMATIC WinCC V7.0 ASIA
to SIMATIC WinCC
Runtime Professional ASIA
V12 SP1
Single license, on DVD
incl. licensing on USB stick
• WinCC V7.0 Runtime
128 PowerTags to
WinCC Runtime Professional
128 PowerTags V12 SP1 1)
• WinCC V7.0 Runtime
512 PowerTags to
WinCC Runtime Professional
512 PowerTags V12 SP1 1)

6AV2105-4BB02-0AE0
6AV2105-4DD02-0AE0

6AV2105-4FF02-0AE0

■ More information
Further information can be found in the Internet at:
http://www.siemens.com/tia-portal

4/24

Siemens ST 80 / ST PC · 2013

6AV2105-4KK02-0AE0

6AV2105-4MM02-0AE0

6AV2107-4DB02-0AE0

6AV2105-4BB02-0AE0

Online software delivery (OSD) 2)
Single license, software and
license key download.
E-mail address required
for the delivery.
• WinCC V7.0 Runtime
128 PowerTags to
WinCC Runtime Professional
128 PowerTags V12 SP1 1)
• WinCC V7.0 Runtime
512 PowerTags to
WinCC Runtime Professional
512 PowerTags V12 SP1 1)
• WinCC V7.0 Runtime
2048 PowerTags to
WinCC Runtime Professional
2048 PowerTags V12 SP1 1)
• WinCC V7.0 Runtime
8192 PowerTags to
WinCC Runtime Professional
8192 PowerTags V12 SP1 1)
• WinCC V7.0 Runtime
65536 PowerTags to
WinCC Runtime Professional
65536 PowerTags V12 SP1 1)
• WinCC V7.0 RC/RT128 / RC/RT
Client to WinCC Client for
Runtime Professional V12 SP1

6AV2105-4BB02-0AK0

6AV2105-4DD02-0AK0

6AV2105-4FF02-0AK0

6AV2105-4KK02-0AK0

6AV2105-4MM02-0AK0

6AV2107-4DB02-0AK0

1)

Each including 1 upgrade license to the WinCC Runtime Professional
options.

2)

Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery

© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Communication

■ Overview
Communication – SIMATIC WinCC Runtime Advanced

Protocol

WinCC Advanced is an open visualization system and offers the
option of connecting the most diverse control systems.

Third-party controllers (from WinCC V11.0) 3)

Number of connectable controllers

Current notes and information about OPC servers from many
different suppliers can be found at:
http://www.opcfoundation.org/
WinCC Advanced supports the standards:
• OPC Data Access 2.05a
• OPC UA Data Access 1.01
• OPC XML Data Access 1.00 (client via DCOM/XML gateway)
Protocol

Description

PC interface

Channel for communication
with max. 4 x Allen Bradley
controllers via Ethernet TCP/IP
with Allen Bradley Ethernet IP
protocol
The controllers ControlLogix /
CompactLogix, SLC500 /
MicroLogix and PLC5 are
supported

CP 1612 A2

Allen Bradley DF1

Channel for communication
with Allen Bradley controllers
via DF1 protocol
The controllers SLC500 /
MicroLogix and PLC5 are
supported 3)

COM1/COM2

Mitsubishi MC TCP/IP

Channel for communication with
max. 4 x Mitsubishi controllers
via Ethernet TCP/IP with Mitsubishi MC TCP/IP protocol
The FX3, Q, and iQ/QnUD
controller series are supported

CP 1612 A2

Mitsubishi FX

Channel for communication
with Mitsubishi controllers
via FX protocol
The FX1N, FX2N controllers are
supported

COM1/COM2

HTTP communication for data
exchange between SIMATIC
HMI (client + server) 1)

CP 1612 A2

Modbus TCP/IP

Channel for communication
with max. 4 x Modicon controllers via Ethernet TCP/IP using
the Modbus TCP/IP protocol
The Quantum, Momentum,
Premium, TSX Micro, Compact
and M340 controllers are
supported

CP 1612 A2

Channel for communication via
Ethernet TCP/IP with max. 8 x
SIMATIC S7 controllers
S7-1200, S7-1500
S7-300, S7-400,
S7-200 with CP 243-1

CP 1612 A2
CP 1613 A2
CP 1623
Modbus RTU

Channel for communication
with Modicon controllers via
the Modbus RTU protocol
The Quantum, Momentum,
and Compact controllers are
supported

COM1/COM2

Channel for communication via
MPI, PROFIBUS with max. 8 x
SIMATIC S7 controllers
S7-1200 with CM 1243-5
(DP master), S7-1500
S7-300, S7-400
S7-200 (only passive S7-200)

CP 5611 A2
CP 5621
CP 5512
CP 5711
CP 5613 A2
CP 5623

Omron Link / Multi Link

Channel for communication
with Omron controllers via the
Link/Multi protocol
The CP1x, CJ1x, CJ2H, CS1x,
and CP2MC controllers are
supported

COM1/COM2

Channel for communication via
PPI with
1 x SIMATIC S7-200
(network operation,
e.g. parallel PG possible)

CP 5611 A2
CP 5621
CP 5512
CP 5711
CP 5613 A2
CP 5623

OPC client 1) 4) for
OPC DA, OPC UA DA,
XML DA

Channel for OPC communication, WinCC can acquire data
from OPC server applications

CP 1612 A2

OPC server for OPC DA

Server applications for
OPC communication;
WinCC provides process data
to OPC clients

CP 1612 A2

SIMATIC HMI
Ethernet TCP/IP
(HTTP communication)
SIMATIC S7
Ethernet TCP/IP
(S7 communication)

MPI, PROFIBUS
(S7 communication)

PPI
(PPI protocol)

Software interface
(S7 communication)

Channel for communication via
software interface with WinAC

Cross-manufacturer

SINUMERIK 2)
Ethernet TCP/IP
(S7 communication)

Channel for communication
via Ethernet TCP/IP
with SINUMERIK 840D sl

CP 1612 A2
CP 1613 A2
CP 1623

MPI
(S7 communication)

Channel for communication
via MPI with
SINUMERIK 840D sl

CP 5611 A2
CP 5621
CP 5512
CP 5711
CP 5613 A2
CP 5623

PC interface

Allen Bradley
Ethernet IP

WinCC Advanced permits the parallel coupling of up to
8 controllers.
Connection to third-party controllers
The following "Coupling overview" table lists third-party protocols
and controllers which are directly supported by WinCC
Advanced. Generally it is also possible to connect third-party
controllers via OPC (OLE for Process Control).

Description

1)

HTTP and OPC communication can be used in combination with the other
couplings; regarding SIMATIC Panels that support HTTP or OPC

communication, see the overview under "System interfaces
(WinCC V11)".
2)

"SINUMERIK Operate WinCC RT Advanced" license required;
for further information, see NC 60 Catalog.

3)

For detailed information regarding supported controllers,
see "System interfaces (WinCC V11)"

4)

Application note:

The parallel use of the OPC client channel allows, for example, the
connection to an SNMP OPC Server for visualization of the data
present there. The SNMP OPC Server enables monitoring of any
network components (e.g. switch) that support the SNMP protocol.
Further information can be foundunder SIMATIC NET communications
systems/SNMP OPC Server.

Siemens ST 80 / ST PC · 2013

4/25

4

© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Communication

■ Overview (continued)
Communication – SIMATIC WinCC Runtime Professional

Protocol

WinCC Professional is an open process visualization system and
offers the option of connecting the most diverse control systems.

SIMATIC S7
SIMATIC S7

Released communication software
Only communication software with the listed (or higher) product
versions should be used. Corresponding SIMATIC NET
upgrades are available for the upgrading of older versions.
Number of connectable controllers
With CP 1613, a maximum of 64 S7 controllers can be connected
via Industrial Ethernet; with CP 5611 a maximum of 8 and with
CP 5613 a maximum of 44 S7 controllers can be connected via
PROFIBUS. With approx. 10 or more controllers, the use of
Industrial Ethernet is recommended.
Client-server communication
Communication between the clients and the server is implemented using the TCP/IP protocol. The construction of a
separate PC-LAN is recommended. For small projects with
correspondingly small message frame advent, a SIMATIC NET
Industrial Ethernet can be used for both process communication
(WinCC/server ↔ PLC) and for PC-PC communication
(WinCC/client ↔ WinCC/server)

4

Siemens ST 80 / ST PC · 2013

CP 1612 A2
CP 1613 A2
CP 5611 A2
CP 5621
CP 5512
CP 5711
CP 5613 A2
CP 5623

Channel for communication with
Allen Bradley controllers via
Ethernet TCP/IP with Ethernet IP
protocol
The controllers ControlLogix /
CompactLogix,
SLC500 / MicroLogix,
and PLC5 are supported

CP 1612 A2

Mitsubishi MC TCP/IP

Channel for communication
with Mitsubishi controllers via
Ethernet TCP/IP with
Mitsubishi MC TCP/IP protocol
The FX3, Q, and iQ/QnUD
controller series are supported

CP 1612 A2

Modbus TCP/IP

Channel for communication with
Modicon controllers via Ethernet
TCP/IP using the Modbus TCP/
IP protocol
The Quantum, Momentum, Premium, TSX Micro, Compact and
M340 controllers are supported

CP 1612 A2

OPC client 1) for
OPC DA, OPC XML DA

Channel for OPC communication, WinCC can acquire data
from OPC server applications

CP 1612 A2

OPC server for
OPC DA, OPC UA DA,
OPC XML DA,
OPC A&E, OPC HDA

Server applications for
OPC communication;
WinCC provides process data
to OPC clients

CP 1612 A2

Cross-manufacturer

1)

4/26

Protocol Suite with channel
units for communication with
SIMATIC S7 via
• Ethernet TCP/IP
(S7 communication) to
S7-1200, S7-1500, S7-300,
S7-400
• MPI, PROFIBUS
(S7 communication) to
S7-1200 with CM 1243-5
(DP master), S7-1500, S7-300,
S7-400
• Software interface
(S7 communication)
to Win AC

Allen Bradley
Ethernet IP

Current notes and information about OPC servers from many
different suppliers can be found at:
http://www.opcfoundation.org/
WinCC Professional supports the standards:
• OPC Data Access 2.05a
• OPC Data Access 3.00
• OPC UA Data Access 1.01
• OPC XML Data Access 1.00
• OPC HDA 1.20
• OPC A&E 1.10

PC interface

Third-party controllers (from WinCC V11.0)

Connection to third-party controllers
The following "Coupling overview" table lists third-party protocols
and controllers which are directly supported by WinCC Professional. Generally it is also possible to connect third-party
controllers via OPC (OLE for Process Control).

Description

Application note:
The parallel use of the OPC client channel allows, for example, the
connection to an SNMP OPC Server for visualization of the data present
there.
The SNMP OPC Server enables monitoring of any network components
(e.g. switch) that support the SNMP protocol.
Further information can be foundunder SIMATIC NET communications
systems/SNMP OPC Server.

© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Communication

■ Overview (continued)
Industrial Ethernet

SIMATIC S7-400
WinCC
Runtime
Advanced

PROFIBUS

SIMATIC S7-1200

*B67B;;B

SIMATIC S7-300

WinCC Runtime Advanced single-user system

WinCC RT
Professional
Client

4
WinCC RT
Professional
Client

WinCC RT
Professional
Client

WinCC RT
Professional
Client

Industrial Ethernet

WinCC RT
Professional
Server

PROFIBUS
SIMATIC S7-400
*B67B;;B

SIMATIC S7-400

WinCC Runtime Professional multi-user system with operable Server

Siemens ST 80 / ST PC · 2013

4/27

© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Communication

■ Overview (continued)
OPC Client
WinCC RT
Professional

Industrial Ethernet
OPC Server
WinCC RT
Advanced

4

SIMATIC S7-300

OPC coupling

4/28

Siemens ST 80 / ST PC · 2013

SIMATIC S7-1200

*B67B;;B

PROFIBUS

© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Communication

■ Ordering data

Order No.

Communication
via Industrial Ethernet TCP/IP
CP 1612 A2

6GK1161-2AA01

PCI card (32-bit) for connection of
a programming device or PC to
Industrial Ethernet
(10/100/1000 Mbit/s) with RJ45
connection via SOFTNET S7 and
SOFTNET PG.

For (32-bit) Windows XP
Professional, Windows 2003 Server,
VISTA Ultimate/Business;
for CP 1612; CP 1612 A2
German/English
• Single license for 1 installation
• Upgrade package for
SIMATIC NET from Edition 2006
• Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2
and Edition 2005

WinCC Runtime Professional:
SOFTNET-S7 Lean (maximum of
8 connections) or SOFTNET-S7
(maximum of 64 connections) must
be installed (SOFTNET-S7 Lean is
included in the scope of delivery of
WinCC Runtime Professional)

CP 1613-A2

SOFTNET-S7 Version 8.0 SP1 /
Edition 2008 SP2 (V7.1)

6GK1161-3AA01

Software for S7 and S5-compatible
communication, incl. PG/OP communication, OPC server and NCM
PC; up to 120 connections, single
license for 1 installation, runtime
software, software and electronic
manual on CD-ROM, license key
on USB flash drive, Class A

For (32-bit) Windows 7 Ultimate,
Professional;
for CP 1612; CP 1612 A2
German/English
(included in the scope of delivery:
Edition 2008 SP2 (V7.1) )

4

Version 8.0 SP1
For (32-bit) Windows 7 Ultimate,
Professional;
for CP 1613; CP 1613 A2,
CP 1623 German/English
(included in the scope of delivery:
Edition 2008 SP2 (V7.1) )

Edition 2008 SP2 (V7.1)

Software for S7-compatible and
S5-compatible communication
incl. OPC server, PG/OP
communication and NCM PC;
up to 8 connections; single license
for one installation of runtime
software,
software and electronic manual
on CD-ROM;
license key on USB stick; Class A

6GK1704-1LW00-3AE1

S7-1613 Version 8.0 SP1 /
Edition 2008 SP2 (V7.1)

Version 8.0 SP1

(included in the scope of delivery of
WinCC V11)

6GK1704-1LW80-3AA0
6GK1704-1LW00-3AE0

PCI card (32 bit) for connecting a
PG/PC to Industrial Ethernet
(communications software must
be ordered separately)

Software for S7 and S5-compatible
communication, incl. OPC server,
PG/OP communication and NCM
PC; up to 64 connections, single
license for 1 installation, runtime
software, software and electronic
manual on CD-ROM, license key on
USB flash drive, Class A

SOFTNET-S7 Lean Version 8.0
SP1 / Edition 2008 SP2 (V7.1)

For (32-bit) Windows 7 Ultimate,
Professional; for CP 1612;
CP 1612 A2 German/English
(included in scope of supply:
Edition 2008 SP2 (V7.1) )
Edition 2008 SP2 (V7.1)

Software requirement:
WinCC Runtime Advanced:
No further installation is required
(SOFTNET-S7)

For (32-bit) Windows XP Professional, Windows 2003 Server,
VISTA Ultimate/Business;
for CP 1612; CP 1612 A2
German/English
• Single license for 1 installation
• Upgrade package for
SIMATIC NET from Edition 2006
• Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2
and Edition 2005

Order No.
Version 8.0 SP1

Edition 2008 SP2 (V7.1)
6GK1704-1CW80-3AA0
6GK1704-1CW00-3AE0
6GK1704-1CW00-3AE1

For (32-bit) Windows XP
Professional, Windows 2003 Server,
VISTA Ultimate/Business;
for CP 1613; CP 1613 A2,
CP 1623 German/English
• Single license for 1 installation
• Upgrade package for
SIMATIC NET from Edition 2006
• Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2
and Edition 2005
CP 1623

6GK1716-1CB80-3AA0
6GK1716-1CB00-3AE0
6GK1716-1CB00-3AE1

6GK1162-3AA00

PCI Express X1 card (32-bit) for
connection of PG/PC to Industrial
Ethernet (communications software
to be ordered separately)

Siemens ST 80 / ST PC · 2013

4/29

© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Communication

■ Ordering data

Order No.

Communication via PROFIBUS
PC adapter USB

6ES7972-0CB20-0XA0

Can be used under Windows XP
CP 5611 A2

6GK1561-1AA01

6GK1562-1AA00

6GK1562-1AM00

Software for S7 Communication incl.
PG/OP protocol, FDL, OPC server;
runtime software, software and
electronic manual on CD-ROM,
license key on USB flash drive,
Class A

6GK1551-2AA00

Version 8.0 SP1

Comprising CP 5621 (32-bit) and
MPI cable, 5 m
CP 5512
PCMCIA card (CARDBUS 32-bit)
for the connection of a PG/notebook
to PROFIBUS or MPI
(communications software included
in WinCC basic package)
CP 5711

4

For (32-bit) Windows 7 Ultimate,
Professional; for CP 5613 A2,
CP 5623 German/English

6GK1571-1AM00

USB adapter for connecting a
PG/PC to PROFIBUS or MPI
(communications software included
in the WinCC basic package)

4/30

6GK1562-3AA00

PCI Express X1 card (32-bit) for
connection of PG/PC to Industrial
Ethernet (communications software
to be ordered separately)
S7-5613 Version 8.0 SP1 /
Edition 2008 SP2 (V7.1)

PCI Express X1 card (32-bit) for
connection of PG/PC to PROFIBUS
(communications software included
in WinCC basic package)
CP 5621 MPI

6GK1561-3AA01

PCI card (32-bit) for connecting
a PC to PROFIBUS
(communications software must
be ordered separately).
CP 5623

PCI Card (32-bit) for connecting a
PG/PC to PROFIBUS
(Communication software included
in the WinCC basic package)
CP 5621

Order No.
CP 5613 A2

Siemens ST 80 / ST PC · 2013

For (32-bit) Windows XP
Professional, Windows 2003 Server,
VISTA Ultimate/Business;
for CP 5613 A2, CP 5623
German/English
• Single license for 1 installation
• Upgrade package for
SIMATIC NET from Edition 2006
• Upgrade package
for SIMATIC NET V6.0, V6.1, V6.2
and Edition 2005

6GK1713-5CB80-3AA0
6GK1713-5CB00-3AE0
6GK1713-5CB00-3AE1

© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) options
SIMATIC WinCC (TIA Portal) options

■ Overview
Options for SIMATIC Panels,
SIMATIC WinCC Runtime Advanced and
SIMATIC WinCC Runtime Professional
SIMATIC WinCC Recipes
for SIMATIC WinCC Runtime Advanced and
SIMATIC WinCC Runtime Professional
• Generation and management of data records for machine or
production data
• Display or entry of data records via a configurable screen
object or via process screens distributed within the project
• Transmission of data records from or to the controller
• Import/export of data records for further processing with other
tools (e.g. MS Excel)
SIMATIC WinCC Logging
for SIMATIC WinCC Runtime Advanced
and SIMATIC WinCC Runtime Professional
• Logging of alarms and process values
• Online evaluation of process value logs and alarm logs
• Evaluation of process value and alarm logs using standard
MS tools such as Excel
SIMATIC WinCC Audit
for SIMATIC Panels and SIMATIC WinCC Runtime Advanced
• Recording of operator actions in an Audit Trail
• Electronic signature for important operator actions relevant to
production
• Audit supports users in meeting special quality requirements,
e.g.
- Production plant requiring validation according to 21 CFR
Part 11 (Food Drug Administration law)
- In respect of traceability according to EU 175/2002
(EU directive)

SIMATIC WinCC Server and SIMATIC WinCC Client
for SIMATIC WinCC Runtime Professional
For setting up a high-performance client-server system
• A number of coordinated HMI stations can be operated in a
single group with networked automation systems
• Client/server solution:
- One server can supply up to 32 connected clients with
process and archive data, alarms, screens and reports
- Depending on the size of the plant, up to 12 servers and
32 clients can be employed.
SIMATIC WinCC WebNavigator
for SIMATIC WinCC Runtime Professional
• Operator control and monitoring of plants via the Internet or
the in-house intranet or LAN
• Web Client permits the operator control and monitoring of a
current WinCC Runtime Professional project via an Internet
browser with ActiveX support.
SIMATIC WinCC DataMonitor
for SIMATIC WinCC Runtime Professional
• Display and analysis of current process states and historical
data on office PCs with standard tools.
• Information can be compiled online individually during
runtime via the Internet/Intranet.
SIMATIC WinCC ControlDevelopment
for SIMATIC WinCC Runtime Advanced and
SIMATIC WinCC Runtime Professional
• Expansion of the basic functionality with proprietary controls.
• Development of proprietary VB.net or C# Controls for
integration in WinCC Runtime Advanced and WinCC Runtime
Professional

SIMATIC Logon
for SIMATIC Panels and SIMATIC WinCC Runtime Advanced
and SIMATIC WinCC Runtime Professional
• Creates user administration on a central computer to which
one or more WinCC stations can be connected over Ethernet.
• With each logging-on/off of a user on one of the connected
stations, SIMATIC Logon checks whether a user password has
been created and that the required privileges exist.
• SIMATIC Logon supports the user in combination with the
Audit option in meeting requirements in accordance with
FDA 21 CFR Part 11 and EU178.
SIMATIC WinCC Sm@rtServer
for SIMATIC Panels and SIMATIC WinCC Runtime Advanced
• Flexible solution for remote access to HMI systems
• Remote maintenance of machines and plants via the Internet/
Intranet
• Reduced downtimes for machines and plants due to direct
remote access
• Flexible solution for remote access to machines and plants

Siemens ST 80 / ST PC · 2013

4/31

4

© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC Recipes

■ Overview

■ Benefits
• Generation and management of machine parameters and
production data on the basis of data records, and exchange
with the automation device, e.g. with the machine.
• Clear tabular representation of the data elements with the aid
of a configurable screen object, or depiction in technological
relationships across several process screens.
• Simple operator guidance through standard functions.
• Export/import of data records for further processing with other
tools (e.g. MS Excel)

■ Function

4

• Option for SIMATIC WinCC Runtime Advanced and
WinCC Runtime Professional for managing data records in
recipes that contain related machine or production data
• The data in a data set can be transferred, for example, from
the control unit to the PLC to switch production to a different
product variant
• Licensing:
- SIMATIC Panels / Multi Panels / Comfort Panels:
No license is required.
- WinCC Runtime Advanced:
One license is required per operator station
- WinCC Runtime Professional:
A license is only required on the server
(or single-user system).

• Input of data records (e.g. operating parameters of a
machine, production data for a plastics machine) on the
HMI device as well as their storage and transfer to the control
• Display or entry of data records via a configurable screen
object or via several process screens distributed within the
project
• The data record elements are coupled with the process via a
direct tag connection
• Transmission of data records from or to the controller
• Powerful interfaces enable a synchronized data exchange
with the controller
• Storage of data records on local data carriers or on remote
data servers via networks
• Logging of data records, e.g. as batch report/shift report
• User-friendly and flexible management of data records by
powerful standard functions
The recipes and the associated data records are created using
a separate, user-friendly WinCC Engineering editor and data is
pre-assigned to them. A configurable table object is used for
displaying the data at runtime. Furthermore, the individual data
record elements can also be displayed directly based on
standard input/output fields across several process screens.
In this way, the data in technological views can be presented
clearly to the operator.
Import and export functions support the importing and exporting
of data via external applications (e.g. MS Excel).

4/32

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC Recipes

■ Technical specifications

■ Ordering data

Order No.

WinCC Recipes
for Runtime Advanced

SIMATIC WinCC Recipes for
Runtime Advanced 1)

The values specified are maximum
values

Single license, license key
only on USB stick

Number of recipes

999

SIMATIC WinCC Recipes +
Logging for Runtime Advanced 1)

Number of elements per recipe 1)

2 000

Single license, license key
only on USB stick

User data length in KB per data
record

256

SIMATIC WinCC Recipes for
Runtime Professional 1)

Number of data records per recipe

5 000

Single license, license key
only on USB stick

1)

When using arrays, each array element represents a recipe element
WinCC Recipes
for Runtime Professional
The values specified are maximum
values

Number of recipes

Unlimited 2)

Number of elements per recipe 2)

500 3)

User data length in KB per data
record

3 000 3)

Number of data records per recipe

5 000 2)

6AV2107-0JA00-0BB0

6AV2107-0HA00-0BB0

6AV2107-0JB00-0BB0

Online software delivery (OSD) 2)
WinCC Recipes for
Runtime Advanced 1)

6AV2107-0JA00-0BH0

Single license, license key
download only; E-mail address
required for the delivery
WinCC Recipes for
Runtime Professional 1)

6AV2107-0JB00-0BH0

Single license, license key
download only; E-mail address
required for the delivery

4

2)

Limited by system resources.

1)

3)

The sum of the number of recipe elements and number of data records
must not exceed a value of 320,000.

One license is required for each operator console. A license is not required
for the engineering system for configuring the runtime option.

2)

Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery

Siemens ST 80 / ST PC · 2013

4/33

© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC Logging

■ Overview

■ Benefits
• Alarm and process value logs enable predictive diagnostics,
which avoids downtimes
• Early detection of danger and fault conditions
• Increase of the product quality and the productivity thanks to
regular analysis of the alarm and process value logs

■ Application
•
•
•
•
•

Transfer of the logs for evaluation and long-term archiving
Detection of recurring error states
Optimization of maintenance cycles
Ensuring the quality standard
Quality assurance and checking the utilization of production
sequences
• Documentation of process sequences

4

• Option for SIMATIC WinCC Runtime Advanced and WinCC
Runtime Professional for logging process values and alarms
• Logging of process values and alarms supports the acquisition and processing of process data from an industrial plant
or machine. Evaluation of the logged process data provides
information about the operating states of the plant or machine
• Licensing:
- SIMATIC Panels / Multi Panels / Comfort Panels:
No license is required.
- WinCC Runtime Advanced:
One license is required per operator station
- WinCC Runtime Professional:
500 Logging Tags are already included in the basic package
The number of Logging Tags can be increased by means of
additional licenses

4/34

Siemens ST 80 / ST PC · 2013

■ Function
• Time-controlled as well as manual or process-controlled
swapping out of process data and alarms for long-term
archiving
• During runtime, swapped out data are read in and selectively
analyzed using WinCC Runtime Professional
- Presentation and evaluation of archived process data based
on a configurable trend display. Reading of the values is
facilitated by a read line.
- Presentation and evaluation of archived alarms based on a
configurable alarm view.
- User-friendly navigation in the logs
• External evaluation of the logs using MS standard tools
• Various log types are supported: sequence and circular logs
• Logging of process values and alarms on external, Windowssupported storage media
- SIMATIC Panels and WinCC Runtime Advanced:
CSV files, RDB files, Microsoft SQL Server via ODBC
- WinCC Runtime Professional: Microsoft SQL Server 2005
• Powerful standard functions permit user-friendly and flexible
utilization of the logs

© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC Logging

■ Technical specifications

■ Ordering data

Order No.

WinCC Logging
for Runtime Advanced

SIMATIC WinCC Logging
for Runtime Advanced 1)

The values specified are maximum
values

Single license, license key
only on USB stick

Number of logs

100

Archivable data

Process values, alarms

SIMATIC WinCC Recipes +
Logging for Runtime Advanced 1)

Cyclical trigger for archiving
process values (variables)

1s

Max. number of entries per log
(incl. sequence log)

500 000 1)

SIMATIC WinCC Logging
for Runtime Professional
1500 Logging Tags

Log types

Circular logs,
sequence logs (max. 400 per log)

Single license, license key
only on USB stick

Data storage format

CSV (Comma Separated Variable),
RDB (Runtime Data Base),
Microsoft SQL database (database
not included in scope of delivery)

SIMATIC WinCC Logging
for Runtime Professional
5000 Logging Tags

1)

6AV2107-0GA00-0BB0

Single license per option,
license key only on USB stick
6AV2107-0GB00-0BB0

6AV2107-0GD00-0BB0

Single license, license key
only on USB stick

Dependent on memory medium used
WinCC Logging
for Runtime Professional
The values specified are maximum
values

WinCC Logging for Runtime
Professional Powerpack
1500 -> 5000 Logging Tags

6AV2107-2GD00-0BD0

Single license, license key
only on USB stick

Number of logs
per single-user station/server

100

Archivable data

Process values, alarms

WinCC Logging Upgrade for
SIMATIC WinCC Archives V7.0
(10 licenses)

Measured values per second, max.

Server/single-user station:
5 000 per sec.

Single license per option,
license key only on USB stick

Log tags per single-user station/
server

80 000 2)

Online software delivery (OSD) 2)

Log types

Circular log with and without
long-term logging

Data storage format

Microsoft SQL 2005 database

2)

6AV2107-0HA00-0BB0

Dependent on the Logging Powerpack used for the log tags.
500 log tags are contained in the basis version.

WinCC Logging for
Runtime Advanced 1)

6AV2107-4GX00-0BF0

4
6AV2107-0GA00-0BH0

Single license,
license key download only
e-mail address required for
the delivery
WinCC Logging for Runtime
Professional - 1500 Logging Tags

6AV2107-0GB00-0BH0

Single license,
license key download only
e-mail address required for
the delivery
WinCC Logging for Runtime
Professional - 5000 Logging Tags

6AV2107-0GD00-0BH0

Single license,
license key download only
e-mail address required for
the delivery
WinCC Logging for Runtime
Professional Powerpack
1500 -> 5000 Logging Tags

6AV2107-2GD00-0BJ0

Single license,
license key download only
e-mail address required for
the delivery
1)

One license is required for each operator console. A license is not required
for the engineering system for configuring the runtime option.

2)

Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery

Siemens ST 80 / ST PC · 2013

4/35

© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC Audit

■ Overview

■ Technical specifications
WinCC Audit
Storage location for Audit Trail when
used on the Panel

Plug-in Flash memory card or
via Ethernet in the higher-level PC

Storage location for Audit Trail when
using WinCC Runtime Advanced

Local hard disk or
via Ethernet in the higher-level PC

Execution platform
SIMATIC Panels

Mobile Panel 277, TP/OP 277

SIMATIC Multi Panels

MP 277, MP 377

SIMATIC Comfort Panels

all

PC systems

SIMATIC WinCC Runtime Advanced

■ Ordering data

4

• Option for SIMATIC WinCC Runtime Advanced as well as
SIMATIC Panels for recording operations in an audit trail, and
electronic signature
• The audit trail is furnished with a security mechanism that
displays subsequent manipulations.
• A user-friendly configuration function, which is included as
standard in WinCC, is used to define the following:
- Which user actions should be recorded in the audit trail
during runtime
- Which important operator actions during execution time
require electronic signature/comments
• Available for the following SIMATIC HMI systems:
- Comfort Panels
- Mobile Panels
- TP/OP 277
- MP 277
- MP 377
- WinCC Runtime Advanced
• Licensing:
- A license is required for every operator control unit
(panel or PC).

■ Benefits
• Audit supports the user in meeting special quality requirements, e.g.
- Production plant requiring validation according to
21 CFR Part 11 FDA 1)
- In respect of traceability according to EU 175/2002 2)
• The entries in the audit trail are uniquely assigned to users.
This means that responsibilities are clearly identifiable.
• The audit trail, stored as a CSV file 3), can be checked via a
security mechanism to find out if subsequent changes have
been made.
• For particularly important user actions, e.g., starting
production or loading new recipes, electronic signatures and
comments can be configured and then called up and logged
during runtime.
1)

The FDA (Food and Drug Administration) is the American public health
body

2)

21 CFR Part 11- law on plant validation

3)

CSV Comma Separated Values

4/36

Siemens ST 80 / ST PC · 2013

SIMATIC WinCC Audit
for SIMATIC Panels

Order No.
6AV2107-0RP00-0BB0

Single license,
license key only on USB stick
SIMATIC WinCC Audit
for Runtime Advanced

6AV2107-0RA00-0BB0

Single license,
license key only on USB stick
Online software delivery (OSD) 1)
WinCC Audit for SIMATIC Panels

6AV2107-0RP00-0BH0

Single license,
license key download only
E-mail address required for the
delivery
WinCC Audit
for Runtime Advanced

6AV2107-0RA00-0BH0

Single license,
license key download only
E-mail address required for the
delivery
1)

Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery

© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) options
SIMATIC Logon

■ Overview

■ Design
SIMATIC Logon for Panels and WinCC Runtime Advanced
SIMATIC Logon and SIMATIC Logon Remote Access are
installed on a central station.

• Option for connecting SIMATIC Panels and PCs with
SIMATIC WinCC Runtime Advanced as well as WinCC
Runtime Professional to a central user administration.
• Creates user administration on a central computer to which
one or more panels or WinCC stations can be connected over
Ethernet.
• With each logging-on/off of a user on one of the connected
stations, SIMATIC Logon checks whether a user password has
been created and that the required privileges exist.
SIMATIC Logon for Panels and WinCC Runtime Advanced
• All users of the SIMATIC Panels or WinCC Runtime Advanced
stations can be managed plant-wide from a central location
• Supports the user in combination with the Audit option in
meeting requirements in accordance with FDA 21 CFR Part 11
and EU178.
• Licensing:
SIMATIC Logon (basic license) and SIMATIC Logon Remote
Access (3-pack license) for the connection of 3 panels or
WinCC Runtime Advanced stations to a central user administration. Additional stations can be connected by using further
SIMATIC Logon Remote Access licenses (3-pack/10-pack).
SIMATIC Logon for WinCC Runtime Professional
• All users of WinCC Runtime Professional can be managed
plant-wide from a central location.
• The central user management with SL utilizes Windows
mechanisms and must be installed on all participating
WinCC Runtime Professional stations.
• Licensing:
SIMATIC Logon (basic license) is included in the basic
package of WinCC Runtime Professional

■ Benefits
• Centralized configuration of all access authorizations of a
distributed system avoids unnecessary travel times. Timeconsuming multiple configurations for each individual local
station become unnecessary. Accordingly, users can be
easily configured from a central location.
• All access data apply throughout the plant on every
connected station. Additional access data on local
subsystems is no longer necessary.

The following Runtime stations are connected to the central
station via the Ethernet network:
• PCs with WinCC Runtime Advanced
• SIMATIC Panels from the 177 series or higher
(with Ethernet interface)
• SIMATIC Mobile Panels from the 177 series or higher
(with Ethernet interface)
• SIMATIC Multi Panels
• SIMATIC Comfort Panels
SIMATIC Logon for WinCC Runtime Professional
The SIMATIC Logon can be used for the central user
management of several WinCC Runtime Professional stations.
Operation in a Windows Workgroup or even in a domain is
possible.

■ Function
Users receive a unique user ID, user name and password.
This information is encrypted and stored at a central point
(for SIMATIC Logon in the Windows user management).
Functions such as changing the password, automatic log-off
after a predefined time and lockout after several incorrect entries
of a password ensure maximum security of operation.
In addition, SIMATIC Logon allows setting up new users online,
plant-wide and across applications, or blocking of existing
users. SIMATIC Logon also supports electronic signature.

■ Ordering data

Order No.

SIMATIC Logon V1.5

6ES7658-7BX51-0YA0

Basic license 1)
For panels or WinCC Runtime
Advanced stations, the corresponding number of additional SIMATIC
Logon Remote Access licenses is
required.
No SIMATIC Logon Remote Access
licenses are required for WinCC
Runtime Professional
SIMATIC Logon Upgrade to V1.5

6ES7658-7BX51-0YE0

SIMATIC Logon Remote Access
(3 clients)

6ES7658-7BA00-2YB0

Remote Access for 3 clients;
Single License for 3 SIMATIC Logon
Remote Access clients;
the number of licensed clients is
determined from the sum of the
installed SIMATIC Logon Remote
Access licenses.
SIMATIC Logon Remote Access
(10 clients)

6ES7658-7BB00-2YB0

Remote Access for 10 clients;
Single License for 10 SIMATIC
Logon Remote Access clients;
the number of licensed clients is
determined from the sum of the
installed SIMATIC Logon Remote
Access licenses.
1)

SIMATIC Logon V1.5 included in scope of supply of WinCC Runtime
Professional.

Siemens ST 80 / ST PC · 2013

4/37

4

© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC Sm@rtServer

■ Overview
Sm@rtServer

Master Station

Sm@rtClient

Operator Station 1

Operator Station 2

Operator Station n

G_ST80_XX_00071

...

Industrial Ethernet

4

• Option for SIMATIC WinCC Runtime Advanced plus
SIMATIC Panels for communication between various
SIMATIC HMI systems.
• Available for the following SIMATIC HMI systems:
- Comfort Panels
- Mobile Panel 177 PN, Mobile Panel 277
- TP 177B PN/DP, OP 177B PN/DP
- TP 277, OP 277
- MP 177, MP 277, MP 377
- WinCC Runtime Advanced
• A SIMATIC HMI system can be used to control or monitor
another system remotely; entry level for client/server configurations for distributed operator stations or for solutions with
head end or control room
• Local operation, visualization and data processing are as
possible as plant-wide access to information. Integrated information flows ensure an overview of the status of all processes.

• Licensing:
The "SIMATIC WinCC Sm@rtServer for Panel" or
"SIMATIC WinCC Sm@rtServer for WinCC Runtime Advanced"
license must be installed on the server HMI device. A license
is not required for the engineering system for configuring the
runtime option.
Note:
When accessing the operator stations via the Sm@rtServer
option, suitable protective measures (including IT security such
as network segmentation) should be taken in order to ensure
safe operation of the system.
You will find more information on the topic of Industrial Security
on the Internet at:
http://www.siemens.com/industrialsecurity

■ Benefits
• Flexible solution for remote access to HMI systems
• Quick elimination of malfunctions or downtimes – thus
increasing the productivity – through global access to
machines/plants by the service and maintenance personnel.

4/38

Siemens ST 80 / ST PC · 2013

• Avoidance of on-site service calls.

© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC Sm@rtServer

■ Application
• Operator control and monitoring of machines covering large
areas with several operator stations by one operator.
• Operator control and monitoring of machine-level HMI
systems from one central station (e.g. head-end station of a
production line or from a control room)

Sm@rtServer

Master Station

• Remote maintenance and servicing of machines/plants over
the Internet/Intranet

Sm@rtClient

Operator Station 1

Operator Station 2

Operator Station n

G_ST80_XX_00071

...

Industrial Ethernet

Application of the Sm@rtClient concept: Coordinated operation of several operator stations

Master Control Station

Sm@rtClient display

Industrial Ethernet

Server 1

Sm@rtServer

Server 2

Sm@rtServer

Server 3

Server 4

Sm@rtServer

Sm@rtServer

G_ST80_XX_00072

PROFIBUS

Use of the Sm@rtClient display: Operator control and monitoring of machine-level HMI systems from one central station

Siemens ST 80 / ST PC · 2013

4/39

4

© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC Sm@rtServer

■ Function

■ Application (continued)

Coordinated operation of several operator stations:
• The HMI application and communication with the controller
takes place via the master station. "Sm@rtClients" can be
activated from here in the case of machines/plants with larger
dimensions which require a larger number of HMI devices.
The Sm@rtClients are then provided with access to the master
station and thus to the process. Access procedures guarantee
that only one operator system can actively access the process
at any given time.
• Embedded in process screens, a configurable screen object
(Sm@rtClient display) represents the screen of the relevant
HMI system (Sm@rtServer)
• Powerful standard functions permit user-friendly and flexible
operation of the display

{jwVpw
pzkuVkzs
t–‹Œ”Vy–œ›Œ™

l•Ž•ŒŒ™•ŽGz›ˆ›–•
wjVwn

p•›Œ™•Œ›

pzkuVkzs
t–‹Œ”Vy–œ›Œ™

Remote operator control and monitoring of SIMATIC HMI systems using
Industrial Ethernet and/or via the Intranet/Internet

jˆšŒGYaG
v—Œ™ˆ›–™GŠ–•›™–“Gˆ•‹G”–•›–™•Ž
œš•ŽG›ŒGp•›Œ™•Œ›Vp•›™ˆ•Œ›Gž›
ˆŠŠŒššG›–G›ŒGŠ–”—“Œ›ŒG‹ŒŠŒb
š–›’Œ šGˆ•‹Gœ•Š›–•G’Œ š

Engineering Station
PC/PG

jˆšŒGXaG
v—Œ™ˆ›–™GŠ–•›™–“Gˆ•‹G”–•›–™•Ž
œš•ŽG›ŒGtŠ™–š–›Gp•›Œ™•Œ›G
lŸ—“–™Œ™

p•‹œš›™ˆ“Gl›Œ™•Œ›

wyvmpi|z

n†z{_W††WWW^]

4

G_ST80_XX_00073

p•‹œš›™ˆ“G

Remote operator control and monitoring of SIMATIC HMI systems using
Industrial Ethernet and/or via the Intranet/Internet

4/40

Siemens ST 80 / ST PC · 2013

Remote control of an operating station:
• The HMI application and communication with the controller
takes place via the HMI system. Using the Sm@rtServer, the
HMI systems in the machines/systems can be serviced
remotely. An access process ensures that only one operator
(either locally at the machine or remotely via Internet Explorer)
can actively access the process at one time.
• Microsoft Internet Explorer V6.0 SP1 or higher is sufficient for
accessing an HMI system.

© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC Sm@rtServer

■ Technical specifications

■ Ordering data
WinCC Sm@rtServer
The values specified are maximum
values

Execution platform
SIMATIC Comfort Panels

all

SIMATIC Panels

Mobile Panel 177 PN,
Mobile Panel 277,
TP/OP 177B PN/DP,
TP/OP 277

SIMATIC Multi Panels

MP 177,
MP 277,
MP 377

PC systems

SIMATIC WinCC Runtime Advanced

Number of Sm@rtClients that
can simultaneously connect to
a Sm@rtServer
Comfort Panel
as Sm@rtServer

2 clients for 4" devices
3 clients for 7", 9", 12" and 15"
devices
2 clients for 19" devices
1 client for 22" devices

Mobile Panel 177 PN,
TP/OP 177B PN/DP,
MP 177 as Sm@rtServer

2 clients

Mobile Panel 277,
TP/OP 277,
MP 277 as Sm@rtServer

3 clients for 6" devices
2 clients for 8" and 10" devices

MP 377 as Sm@rtServer

3 clients for 12" devices
2 clients for 15" devices
1 client for 19" devices

WinCC Runtime Advanced as
Sm@rtServer

5 clients

Order No.

WinCC Sm@rtServer
for SIMATIC Panels 1)
Single license, license key
only on USB stick

6AV2107-0CP00-0BB0

WinCC Sm@rtServer
for Runtime Advanced 1)
Single license, license key only on
USB stick

6AV2107-0CA00-0BB0

Online software delivery (OSD) 2)
WinCC Sm@rtServer
for SIMATIC Panels 1)
Single license, license key
download only
E-mail address required for
the delivery

6AV2107-0CP00-0BH0

WinCC Sm@rtServer
for Runtime Advanced 1)
Single license, license key
download only
E-mail address required for
the delivery

6AV2107-0CA00-0BH0

4

1)

The license must be installed on the Sm@rtServer HMI device. A license is
not required for the engineering system for configuring the runtime option.

2)

Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery

Siemens ST 80 / ST PC · 2013

4/41

© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC Server / WinCC Client

■ Overview

WinCC
Client

WinCC
Client

WinCC
Client

TCP/IP

SIMATIC S7-1200
SIMATIC S7-300

SIMATIC S7-400

4

• Option for SIMATIC WinCC Runtime Professional, which
permits the configuration of a powerful client/server system
• One of the following operating systems must be available to
install the option on the server: Windows Server 2003,
Windows Server 2003 R2, Windows Server 2008 or
Windows XP Professional. When using Windows XP
Professional, max. 3 clients can be connected.
• A number of coordinated HMI stations can be operated in a
single group with networked automation systems

4/42

Siemens ST 80 / ST PC · 2013

n†z{_W††WW[^Y

Process bus

• Client/server solution: One server can supply up to
32 connected clients with process and archive data, alarms,
screens and reports
- Requirement: Network connection (TCP/IP) between the
server PC and the connected clients
• Licensing:
- A WinCC Runtime Professional license on the server with the
appropriate number of PowerTags and the "WinCC Server for
RT Professional" license.
- The "WinCC Client for RT Professional" license on the clients.

© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC Server / WinCC Client

■ Benefits
• Integrated scalability from the single-user system to the client/
server solution
• Considerably expanded quantity structure, relieves the load
on the individual servers, and thus better performance
through the distribution of the overall application or of the
tasks among several servers

■ Application
In a complex plant, WinCC Runtime Professional can be
configured as a distributed system depending on the requirements:
• Functional distribution (e.g. alarm server, log server, etc.), or
• Distribution corresponding to the physical plant structure
(e.g. body-in-white, paint shop, etc.).

■ Function
All process data of a WinCC project is stored in different Runtime
databases, e.g. alarms, trend values, etc. These Runtime
databases are located on a central computer, the WinCC Server,
instead on each HMI device. The operator stations, i.e. the
WinCC Clients, then access the WinCC Server.
WinCC Clients and WinCC Server are independent systems.
You can also connect WinCC Clients subsequently. Alternatively,
you can activate and deactivate a project from a WinCC Client.

■ Ordering data

Order No.

SIMATIC WinCC server
for Runtime Professional
Single license, license key
only on USB stick

6AV2107-0EB00-0BB0

SIMATIC WinCC Client
for Runtime Professional V12
Single license, license key on USB
stick, software and documentation
on DVD

6AV2107-0DB02-0AA0

SIMATIC WinCC Client for
Runtime Professional ASIA V12
Single license, license key on USB
stick, software and documentation
on DVD

6AV2107-0DB12-0AA0

Online software delivery (OSD) 1)
SIMATIC WinCC server
for Runtime Professional
Single license, license key
download only,
e-mail address required for the
delivery

6AV2107-0EB00-0BH0

SIMATIC WinCC Client
for Runtime Professional V12
Single license, software an
d license key download.
E-mail address required for
the delivery

6AV2107-4DB02-0AK0

4

A license is not required for the engineering system for
configuring the runtime option.
1)

Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery

Siemens ST 80 / ST PC · 2013

4/43

© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC WebNavigator

■ Overview
~•jj
zjhkhGŠ“Œ•›š

~•jj
~Œ‰GŠ“Œ•›

~•jj
kˆ›ˆt–•›–™

shu
~•jjGšŒ™Œ™
RG~Œ‰uˆŽˆ›–™V
kˆ›ˆt–•›–™
šŒ™Œ™

wyvmpul{
wyvmpi|z

n†z{_W††WW\\]

4

• Option for SIMATIC WinCC Runtime Professional for operating
and monitoring plants over the Internet, company Intranet or
LAN.
• Configuration from:
- A web server with SIMATIC WinCC Runtime Professional as
single-user or server version and a web client that permits
operator control and monitoring of a current WinCC Runtime
Professional project using the Internet Explorer.
• Licensing:
- A license is required for using the Web server.
- Server-based licenses are available for access to the web
server by 3, 10, 25 or 50 clients.
- Client-based licenses are available for guaranteed access to
the web server (Diagnostics Client)

4/44

Siemens ST 80 / ST PC · 2013

Note:
When accessing the operator stations via the
WinCC WebNavigator option, suitable protective measures
(including IT security such as network segmentation) should be
taken in order to ensure safe operation of the system.
You will find more information on the topic of Industrial Security
on the Internet at:
http://www.siemens.com/industrialsecurity

© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC WebNavigator

■ Benefits
• Operator control and monitoring across long distances and
on different platforms (PC, local panel, mobile PDA)
• Large configurations with up to 50 operator stations
• Fast update rates due to event-driven communication
• Optimally tailored clients for operating and monitoring,
analysis, service and diagnostics
• Acceptance of configuration data for the web, generally
without changes
• Minimum maintenance costs due to central software
administration
• High security standards and availability
- Support for commonly used security mechanisms
(routers, firewalls, proxy servers)
- WinCC access authorizations and user administration
• Support of Microsoft Internet Explorer, including "tabbed
browsing". A new license is not required for separate tabs.
• With the WinCC Web Viewer (WinCC Viewer RT), the process
screens can be displayed on the web client independently of
the Internet Explorer. Settings for the client are made on the
client itself. The WinCC Web Viewer can also be used in
conjunction with the MS Terminal Service.
• The SIMATIC WinCC WebNavigator can also be operated in
"view only" mode and is thus used as tool for monitoring and
navigating using Internet Explorer or WinCC Web Viewer
(WinCC Viewer RT).
• Web server logins and logouts are recorded in the alarm and
audit log.
• There is a gadget available for the Windows 7 operating
system in which selected WinCC process screens can be
displayed. No additional WebNavigator license is required for
the gadget. The WebNavigator server can be selected directly
via the gadget.
• Security is increased by adjustable automatic logout. If an
automatic logout is to take place, an absolute or inactive time
period can be set.
Highlights:
• Multiple Web servers can be accessed from a single Web
client
• User-friendly services and tools for distributing customized
objects (controls, files) to web clients can be supplied for use
as an integration platform. These components can then also
be integrated into cross-web/server navigation.
• Both Internet Explorer and the supplied, browser-independent
WinCC Web Viewer (WinCC Viewer RT) can be used as a front
end
• Access to WebNavigator Server of the WinCC V7.x series.

■ Application
In addition to the typical use of the WebNavigator in WANs
(Wide Area Networks), the WebNavigator can also be used to
implement especially low-cost applications. This especially
includes applications that have a pronounced distributed
structure (water/wastewater, oil and gas), or in which access to
process information is only sporadic (building management).
The WebNavigator also permits vertical integration, i.e. a
networked IT landscape with integrated data flow between the
planning and operating level of a company. Only a standard
browser is required for direct access to current process information.
In addition to the standard WebNavigator licensing, there is the
"Diagnostics Client" with identical functionality but different
licensing. It is especially suitable for the following applications:
• Remote diagnostics/operation of several unmanned
WinCC Runtime Professional stations
• Central control rooms that monitor several web servers via one
user interface
• Maintenance personnel who require guaranteed access to
the server at any time, regardless of the number of users
already logged on to the server. On the server side, only one
WebNavigator Diagnostics Server license or, alternatively, one
Standard WebNavigator license is required.

4

■ Design
Licenses for the WebNavigator
The WebNavigator Client software can be installed as many
times as required without the need for a license.
• Server-based licensing
- A license is required for using the WebNavigator Server.
- Licenses are available for simultaneous access to the Web
server by 3, 10, 25 or 50 clients.
• Diagnostics client licensing
- For cost-optimized access by one or a small number of
WebNavigator clients to numerous Web servers (e.g. for
diagnostic purposes). This client license provides
guaranteed access to Web servers at any time. In respect of
function there is no difference compared with regular
WebNavigator clients and the two can be mixed.
WebNavigator Clients are capable of accessing several different
Web Servers.
Thin client solutions
The WebNavigator can also run under Windows Server 2003 or
Windows Server 2008 terminal services. A Windows Server 2003
or Windows Server 2008 (or higher) operating system is
required. This makes it possible to connect SIMATIC Thin Clients
as visualization stations to WinCC Runtime Professional, for
example.
For this purpose, the Windows terminal services must be
installed on the PC on which the Web Client is installed.
A Windows Server 2003 or Windows Server 2008 (or higher)
operating system is required. Up to 25 thin clients can be
connected to one terminal server.
Applications:
• Mobile devices
• Handhelds
• Rugged on-site visualizations

Siemens ST 80 / ST PC · 2013

4/45

© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC WebNavigator

■ Design (continued)
Hybrid configuration
System requirements: WinCC WebNavigator – Server V12
• Windows 7 SP1 (32- and 64-bit) Business, Enterprise and
Ultimate (max. 3 Clients)
• Windows XP Professional Service Pack 3 (max. 3 clients)
• Windows Server 2003 SP2
• Windows Server 2008 SP2 32-bit
• Windows Server 2008 R2 SP1 64-bit
• Internet Explorer V7.0, V8.0, V9.0
• Microsoft SQL Server 2008 R2 SP1 32-bit
(included in the WinCC product delivery)
• WinCC Basic System V12
System requirements: WinCC WebNavigator – Client V12
• Internet Explorer 7, IE 8, IE9

4

System requirements: WinCC WebNavigator – Server V11
• Windows 7 (32-bit) Business, Enterprise and Ultimate
(max. 3 clients)
• Windows XP Professional Service Pack 2 (max. 3 clients)
• Windows Server 2003 SP2 and Windows Server R2 SP2
• Windows Server 2008
• Internet Explorer 7 as well as Internet Explorer 8
• Microsoft SQL Server 2005 SP2 (scope of supply of WinCC)
• WinCC Runtime Professional V11
System requirements: WinCC WebNavigator – Client V11
• Internet Explorer 7 as well as Internet Explorer 8

■ Function
WinCC Professional makes setting up and configuring a
WebNavigator server very easy. WinCC process screens to be
visualized via the Internet are created as usual in WinCC Professional and the web access is activated via a process screen
option. To display WinCC process screens on the web client, the
Microsoft Internet Explorer or browser is used independent of
the supplied WinCC Web Viewer (WinCC Viewer RT).
The operator on the Web Client is integrated in the central
WinCC user administration and can operate and monitor the
system according to the configured access rights.
The WebNavigator supports all standard security mechanisms
that can be used for applications on the Internet, e.g. routers,
firewalls and proxy servers.

■ Ordering data

Order No.

SIMATIC WinCC WebNavigator
for Runtime Professional
Single license, license key
only on USB stick
• 3 clients, runtime software
• 10 clients
• 25 clients
• 50 clients
• 100 clients
• 150 clients

6AV2107-0KD00-0BB0
6AV2107-0KF00-0BB0
6AV2107-0KH00-0BB0
6AV2107-0KK00-0BB0
6AV2107-0KM00-0BB0
6AV2107-0KP00-0BB0

SIMATIC WinCC WebNavigator
for Runtime Professional
Powerpacks
Single license, license key
only on USB stick
• From 3 to 10 clients
• From 10 to 25 clients
• From 25 to 50 clients
• From 50 to 100 clients
• From 100 to 150 clients

6AV2107-2KF00-0BD0
6AV2107-2KH00-0BD0
6AV2107-2KK00-0BD0
6AV2107-2KM00-0BD0
6AV2107-2KP00-0BD0

SIMATIC WinCC WebNavigator
Diagnostics Server/Client
Single license, license key only on
USB stick
• WinCC WebDiagnostics Server
for Runtime Professional, Runtime
software
• WinCC WebDiagnostics Client for
Runtime Professional, Runtime
software

6AV2107-0KR00-0BB0

6AV2107-0KT00-0BB0

New type of delivery
Online software delivery (OSD) 1)
WinCC WebNavigator
for Runtime Professional
Single license, license key
download only,
e-mail address required for
the delivery
• 3 clients
• 10 clients
• 25 clients
• 50 clients
• 100 clients
• 150 clients

6AV2107-0KD00-0BH0
6AV2107-0KF00-0BH0
6AV2107-0KH00-0BH0
6AV2107-0KK00-0BH0
6AV2107-0KM00-0BH0
6AV2107-0KP00-0BH0

WinCC WebNavigator for
Runtime Professional
Powerpacks
Single license, license key
download only,
e-mail address required for
the delivery
• 3 to 10 clients
• 10 to 25 clients
• 25 to 50 clients
• 50 to 100 clients
• 100 to 150 clients

6AV2107-2KF00-0BJ0
6AV2107-2KH00-0BJ0
6AV2107-2KK00-0BJ0
6AV2107-2KM00-0BJ0
6AV2107-2KP00-0BJ0

WinCC WebNavigator
Diagnostics Server/Client
Single license, license key
download only,
e-mail address required for
the delivery
• WinCC Web Diagnostics Server
for Runtime Professional
• WinCC Web Diagnostics Client
for Runtime Professional

6AV2107-0KR00-0BH0
6AV2107-0KT00-0BH0

A license is not required for the engineering system for configuring the
runtime option.
1)

4/46

Siemens ST 80 / ST PC · 2013

Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery

© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC DataMonitor

■ Overview

~•jj
zjhkhGŠ“Œ•›š

~•jj
~Œ‰GŠ“Œ•›

~•jj
kˆ›ˆt–•›–™

shu
~•jjGšŒ™Œ™
RG~Œ‰uˆŽˆ›–™V
kˆ›ˆt–•›–™
šŒ™Œ™

wyvmpul{

n†z{_W††WW\\]

wyvmpi|z

• The WinCC DataMonitor is used for displaying and evaluating
current process states and historical data on office PCs using
standard tools such as Microsoft Internet Explorer or Microsoft
Excel. In doing so, the DataMonitor client is supplied by a Web
server with current and historic process data and alarms. All
staff ranging from machine operators to corporate managers
can use the DataMonitor to obtain information.
• DataMonitor is a suite of Internet-capable tools:
- Process Builder
Tool exclusively for monitoring and navigating via
WinCC Runtime Professional screens using Internet Explorer
(view only) or the WinCC Web Viewer (WinCCViewerRT)
- Excel Workbooks
Logging tool that integrates WinCC Runtime Professional
Archive and online values into Microsoft Excel and supports
online analysis
- Published Reports
Event or time-driven implementation of Excel or PDF reports
for the output of process data and analysis results
- Webcenter
Individual configuration of Internet pages and summary of
information within a portal with reference to WinCC Runtime
Professional applications
- Trends and Alarms
(tables and graphs) are preconfigured Webcenter pages

• DataMonitor does not require manual client installation
because it loads the required components from the web
server.
• There is no installation required on the client for the Webcenter
and Trends and Alarms functions.
• Licensing:
- Licenses for access by 1, 3, 10, 25, or 50 DataMonitor clients
are available.
- Any combination of DataMonitor and WebNavigator licenses
can be used in an application.
Note:
When accessing the operator stations via the
WinCC DataMonitor option, suitable protective measures
(including IT security such as network segmentation) should
be taken in order to ensure safe operation of the system.
You will find more information on the topic of Industrial Security
on the Internet at:
http://www.siemens.com/industrialsecurity

Siemens ST 80 / ST PC · 2013

4/47

4

© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC DataMonitor

■ Benefits

■ Function

• Information can be compiled online individually during
runtime via the Internet/Intranet.
• Efficiently monitor and analyze production lines.
- Display and evaluation of current process states and
historical data on remote office PCs with standard tools such
as Microsoft Internet Explorer or Excel.
- Easy access to production data via the Intranet or Internet
- Quick ascertainment of the production situation
• Easily collect and distribute information.
- Automated report creation
- No additional configuration effort through direct use of
screens from the WinCC project
- No training required for standard products
- Easy exchange of configuration data
• Substantiate decisions with reports.
- Evaluation via ready-made templates for special analyses
of the business processes (e.g. reports, statistics)
- Display bottlenecks transparently
- Individual views for user and situation
- Relative and absolute timeframe for information generation
• View production status anywhere and anytime.
- Individual views of information in production
- View the process and system operation
- Historical data can be compiled online individually

4

Highlights:
• With the Webcenter function, WinCC Runtime Professional
archive tags can be accessed without changing the configuration system.
• Dedicated Internet pages can be created for displaying data
with the Webcenter. For this purpose, the following tools,
which can be integrated in the Internet sites, are available.
- Bar chart, pie chart, trend curve display
- Process value table and statistics functions for the process
values
- Alarms, hit list for alarms
- Message text display for individual message texts, message
display, selection list of created reports,
- Links to internal and external pages
- Display of graphics in jpg format
- Representation of the WinCC Runtime Professional process
screens
• The analyses can be made with relative or absolute time
specification. This enables comparisons of identical time
periods on different days.
• Reports generated with Excel or with WinCC Professional can
be made available on the DataMonitor server or e-mailed
automatically to the relevant group of people based on time
intervals or triggered by events.
• Connections to WinCC Runtime Professional and to swapped
out archives can be established
• Support of Microsoft Internet Explorer version, including
"tabbed browsing".

4/48

Siemens ST 80 / ST PC · 2013

• All tools are fully Internet-compatible and, therefore, support
access via any type of connection (LAN, GSM, radio, modem,
Internet, etc.).
• All popular security mechanisms such as login/password,
firewalls, encryption, etc. are supported.
• Users can combine the available tools at will. Licensing only
takes into account simultaneous access to one Web server.
• For display purposes, screens from the WinCC project can be
used or special overview displays configured. Animations,
scripts, navigation and access rights remain valid.
• The WinCC DataMonitor supports a display function only.
• Company-wide Excel reports, which contain historical and
current process values, can be stored centrally for general
access (reports, statistics). However, local queries to meet
individual requirements can be compiled and executed
online. Plot and tabular representation are supported for
archive data already swapped out.
• Data can be automatically entered into created report
templates and distributed by e-mail.
• Pre-made elements make the assembly of individual web
pages easier for evaluating information.
• Individual information compilation on one or more Internet
pages with the option of branching to other detail pages.
• Pre-made Internet pages for trend and alarm display enable
an ad-hoc entry to Internet data evaluation.
• An higher-level navigation feature provides a common
framework for the various tools.
• Enhanced user management for the web center in order to
assign individual Internet pages and created reports to
specific user groups.
• A search function facilitates the management of connections
to the WinCC server.
• Swapped out archives can be connected and evaluated in the
DataMonitor WebCenter.
• Excel reports created offline can be loaded onto the
DataMonitor server and are thus made available to selected
user groups or for automatic distribution.

© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC DataMonitor

■ Ordering data
SIMATIC WinCC DataMonitor
for Runtime Professional
Single license, license key
only on USB stick
• 1 client
• 3 clients
• 10 clients
• 25 clients
• 50 clients
SIMATIC WinCC DataMonitor
for Runtime Professional
Powerpacks
Single license, license key
only on USB stick
• From 1 to 3 Clients
• From 3 to 10 Clients
• From 10 to 25 Clients
• From 25 to 50 Clients

Order No.

Order No.
Online Software Delivery (OSD) 1)

6AV2107-0LB00-0BB0
6AV2107-0LD00-0BB0
6AV2107-0LF00-0BB0
6AV2107-0LH00-0BB0
6AV2107-0LK00-0BB0

6AV2107-2LD00-0BD0
6AV2107-2LF00-0BD0
6AV2107-2LH00-0BD0
6AV2107-2LK00-0BD0

SIMATIC WinCC DataMonitor
for Runtime Professional
Single license, license key
download only,
e-mail address required for
the delivery
• 1 client
• 3 clients
• 10 clients
• 25 clients
• 50 clients

6AV2107-0LB00-0BH0
6AV2107-0LD00-0BH0
6AV2107-0LF00-0BH0
6AV2107-0LH00-0BH0
6AV2107-0LK00-0BH0

SIMATIC WinCC DataMonitor
for Runtime Professional
Powerpacks
Single license, license key
download only,
e-mail address required for
the delivery
• From 1 to 3 clients
• From 3 to 10 clients
• From 10 to 25 clients
• From 25 to 50 clients

6AV2107-2LD00-0BJ0
6AV2107-2LF00-0BJ0
6AV2107-2LH00-0BJ0
6AV2107-2LK00-0BJ0

A license is not required for the engineering system for configuring the runtime option.
1)

Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery

Siemens ST 80 / ST PC · 2013

4/49

4

© Siemens AG 2013

HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC ControlDevelopment

■ Overview

■ Ordering data

You use the ControlDevelopment option to create your own
.net controls for controlling and monitoring processes. You can
use the controls in screens for WinCC Runtime Advanced and
WinCC Runtime Professional. You create the controls based
on the standard controls from Visual Studio 2005/2008
Professional .net.
Application examples:
• Special trend views
• Own recipe managements
• Complex display objects

■ Benefits
The ControlDevelopment option enables user-specific software
solutions based on a proven building block principle:
• Lower development overhead by using standards
(Visual Studio 2005/2008 Professional .net)
• Very short "Time-to-Market" resulting in a competitive
advantage
• Utilization of tried components and proven industrial functionality

4

The development of proprietary controls for WinCC Runtime
Advanced and WinCC Runtime Professional does not require
expensive, special hardware.

4/50

Siemens ST 80 / ST PC · 2013

WinCC ControlDevelopment V12
• Runtime license,
single license, software
and documentation on CD
• Runtime software,
single license, software download
(e-mail address required for the
delivery) 1)
1)

Order No.
6AV2107-0TA02-0DA8

6AV2107-0TA02-0DG8

Current information and availability regarding the new delivery package
can be found at:
http://www.siemens.com/tia-online-software-delivery

■ More information
Further information can be found in the Internet at:
http://www.siemens.com/tia-portal

© Siemens AG 2013

HMI Software
Software for energy management
Software for energy management

■ Overview
SIMATIC offers numerous reasons for corporate energy
management in industrial plants.
However, there is one in particular:
It makes an important contribution towards improving plant
productivity. This results in enhanced competitiveness. Energy
management with SIMATIC makes energy flows transparent in
production plants. This supports the analysis and derivation of
energy saving potential.
The result:
Permanently increased efficiency, higher productivity and an
improved cost situation.

4

Siemens ST 80 / ST PC · 2013

4/51

© Siemens AG 2013

HMI Software
Software for energy management
SIMATIC B.Data

■ Overview
SIMATIC B.Data V5.3 SP2 Energy Management System
SIMATIC B.Data is a modular, cross-sector energy management
system for industrial firms.

Energy management – Company portal

4
WinCC

Automation
field level

Energy planning and procurement

Energy controlling

Energy purchase
Purchase support
Scenario calculator

Emission
CO2 emission monitoring
Wastewater disposal

Forecast
Energy forecast
Budget planning

Energy accounting
Cost center allocation
Evaluation/invoicing

Monitoring and reporting
Connection of external systems
Facility management
ERP (e.g. SAP R/3)
Maintenance management

Energy reporting system
Analysis and reporting
Workflow system
Intranet/Internet viewer

Energy schedule
Energy purchase schedule
Specifications for Load management

Energy and material balance
KPI calculation
Production allocation

Fault/alarm management
Alarms/messages
Remote alarms (text message)

Operation and control system
Central detection
Plant visualization
Data processing and archiving

Interfaces to lower-level systems

Meters/
measuring
devices

Process
control/
building
management
systems

PLCs

Load management
Load shedding
Load control

Circuitbreakers

Mobile
data
acquisition

G_ST80_XX_00379

B.Data

■ Benefits
The option SIMATIC B.Data forms the basis of a cost-effective
energy management system for reducing energy costs and
increasing energy efficiency, and it confers the following
immediate benefits:
• It creates company-wide transparency, thanks to continuous
energy balancing and materials balancing for the power
generation systems and loads
• It allows energy costs to be allocated according to the costsby-cause principle and permits transfer to the billing system
(e.g. SAP R/3 CO)
• It generates characteristic values for well-informed suggestions for increasing the efficiency of power generation systems
and loads

4/52

Siemens ST 80 / ST PC · 2013

• It provides planning reliability thanks to production-related
load and demand forecasts
• It supports purchasing with cost-optimized energy
procurement
• It fulfills the legal obligations for monitoring and reporting on
greenhouse gas emissions (CO2 emissions)
• It relieves personnel of extra work through automatically
updating internal and external energy reports
• It supports customers in the continuous improvement of
energy efficiency (e.g. ISO 50001) by integrated project
management for energy efficiency measures

© Siemens AG 2013

HMI Software
Software for energy management
SIMATIC B.Data

■ Design
SIMATIC B.Data V5.3 SP2 Basic System
The B.Data Basic System is available in variants for 100, 500,
1 000 and 30 000 tags and comprises the following components:
• A B.Data acquisition component (WinCC, OPC, etc.)
• A B.Data Client
• B.Data Mobile
• ERP interface
• Reporting, Trender, Visu, document management, Matrix, KPI,
Profile
SIMATIC B.Data Software Update Service (SUS)
For each B.Data Basic System there is a corresponding SUS
(Software Update Service), which is dependent on the number
of tags. The SUS is valid for 1 year. The contract is automatically
extended by 1 more year unless canceled 3 months prior to
expiration.
SIMATIC B.Data V5 Expansions
The scope of B.Data can be extended by purchasing add-on
packages:
• B.Data Web Server
• B.Data Client
• B.Data Energy Forecasting and Planning
• B.Data Acquisition Component

■ Function
Acquisition and pre-processing of energy and operating
data from WinCC
• In addition to an interface to WinCC, SIMATIC B.Data also
offers the latest interface standards such as OPC, ODBC,
ASCII, or XML
• Preprocessing of energy data in a real-time calculation core
that can be freely modeled including a formula editor for
defining and configuring new calculation functions (heat
calculations for boilers, quality for cogeneration plants, etc.)
• B.Data Mobile for mobile recording of energy data including
route planning for meter reading operations
• Management and analysis of energy data
• Automatic plausibility check and generation of simulated
values
• Long-term archive with versioning, compression and consolidation functions
• Measured value editor for entering and processing energy
and operating values
• Trender for presenting up-to-date (online) and historical load
curves (trends), also for setpoint/actual value analyses
• Energy management dashboards for creating cross-company
transparency through visualization of parameters and display
of Sankey diagrams.

Siemens ST 80 / ST PC · 2013

4/53

4

© Siemens AG 2013

HMI Software
Software for energy management
SIMATIC B.Data

■ Function (continued)
Energy and material balance
Freely parameterizable balancing of the energy flows of various
media such as electricity, heat, gas, steam, and emissions
(CO2) in the B.Data Plant Explorer
• Calculation of characteristic values (KPIs, efficiency coefficients, etc.) with direct reference to production (batches,
quantities, etc.).

4
Energy accounting (costs and revenue accounting)
Calculation and allocation/assignment of energy costs to plants
and/or customers/cost units in accordance with the costs-bycause principle. The bottom up (measurement) and top down
(allocation) procedures are supported here
• Flexible modeling of the hierarchic accounting structures in
the Plant Explorer
• Tariff allocation of quantities, flexible price assessment with
tariff and price time series
• Transfer of costs/revenues to the ERP system
(e.g. SAP R/3 CO)

10%

90%

Consumption area
(e.g.: Building 1)

20%
1 ... n

75%

80%

Consumption area
(e.g.: Building 2)

25%

Counter 1

Counter 3
Counter 2

4/54

Siemens ST 80 / ST PC · 2013

Factors are based on:
• Numbers of
employees
• Area data
• Allocation formula
• etc.

100% Distribution
ensured
G_ST80_XX_00380

Accounting area
(e.g. Cost center)

Losses

Energy planning
• Generation of requirement forecasts based on productiondependent factors (production planning) and basic load
profiles (typical days)
• Generation of energy schedules for registering with the
energy suppliers. Energy reporting
• Freely parameterizable report generator for creating
balances, protocols, shift logs, bills
• Fully automated reporting with task management, e-mail
dispatch and document management
• B.Data Intranet/Internet viewer (web client) for company-wide
viewing of reports and results
• Information about discrepancies from specified parameters
through KPI warning system

© Siemens AG 2013

HMI Software
Software for energy management
SIMATIC B.Data

■ Technical specifications

■ Ordering data
SIMATIC B.Data V5.3 SP2 2)

Operating system

• Windows Server 2003 SP2 32 bit
Eng./Ger.
• Windows Server 2008 Std. Edition
32 bit Eng./Ger.
• Windows Server 2008 R2 Eng./Ger.
• Windows XP Professional SP3
32 bit Eng./Ger.
• Windows 7 Professional/Ultimate
32 bit/64 bit Eng./Ger.
• Minimum of 2 GB RAM

Interface

In addition to an interface to WinCC,
B.Data also offers the latest interface standards, such as OPC,
ODBC, ASCII and XML.

WinCC versions 1)

• SIMATIC WinCC V7.0 SP3, V7.2
• SIMATIC WinCC RT Professional
V11 SP2, V12

PCS 7 versions 3)

• SIMATIC PCS 7 V8.0 SP1

1)

If an acquisition computer is installed on a WinCC system,
these requirements must also be complied with.

2)

The SIMATIC B.Data V5.3 Basic System is delivered with an Oracle
Database Standard Edition Embedded. For larger quantity frameworks
(as of 250 million stored measured values), you need Oracle Database
Enterprise Edition with Partitioning Option, which must be ordered
separately from Oracle.

3)

The SIMATIC B.Data system for connection to the PCS 7 must always be
installed on a separate PC.

■ More information
Further information can be found on the Internet at:
www.siemens.com/simatic-bdata

Order No.

SIMATIC B.Data V5.3 SP2
Basic System
In the basic system of B.Data, the
following components are already
included:
One B.Data acquisition component
(WinCC, OPC, etc.),
1 B.Data client, B.Data Data Mobile,
ERP interface, Reporting, Trender,
Visu, document management,
Matrix, KPI, Profile
• Basic system, 100 tags1)
• SUS for 100 tags2)
• Basic system, 500 tags1)
• SUS for 500 tags2)
• Basic system, 1 000 tags1)
• SUS for 1 000 tags2)
• Basic system, 30 000 tags1)
• SUS for 30 000 tags2)
SIMATIC B.Data V5 Powerpack
• Basic system, Powerpack 1)
Tag upgrade by 1 level
• SUS and support contract
for Powerpack 2)
SIMATIC B.Data V5.3 Trial License

6AV6372-1DF05-3AX0
6AV6372-1DF00-0AL1
6AV6372-1DF05-3BX0
6AV6372-1DF00-0BL1
6AV6372-1DF05-3CX0
6AV6372-1DF00-0CL1
6AV6372-1DF05-3DX0
6AV6372-1DF00-0DL1
6AV6372-1DF05-3XX0
6AV6372-1DF00-0XL1
6AV6372-1DF15-3AX0

Basic System, 90 days 5)

4

SIMATIC B.Data V5 Expansions 3)
The functional scope of B.Data can
be expanded with the following
packages.
SIMATIC B.Data Web Server
• incl. 3 web clients
• incl. 20 web clients

6AV6372-1DF25-2AX0
6AV6372-1DF25-2BX0

SIMATIC B.Data Client

6AV6372-1DF35-2AX0

SIMATIC B.Data
Prognosis & Planning

6AV6372-1DF45-2AX0

SIMATIC B.Data
Acquisition Component

6AV6372-1DF55-2AX0

SIMATIC B.Data upgrades
• SIMATIC B.Data 100 tags,
upgrade V5.2 -> V5.3 SP2 4)
• SIMATIC B.Data 500 tags,
upgrade V5.2 -> V5.3 SP2 4)
• SIMATIC B.Data 1 000 tags,
upgrade V5.2 -> V5.3 SP2 4)
• SIMATIC B.Data 30 000 tags,
upgrade V5.2 -> V5.3 SP2 4)

6AV6372-1DF05-3AX4
6AV6372-1DF05-3BX4
6AV6372-1DF05-3CX4
6AV6372-1DF05-3DX4

1)

The SIMATIC B.Data V5.3 Basic System is delivered with an Oracle
Database Standard Edition Embedded. For larger quantity frameworks
(as of approx. 250 million stored measured values), you need Oracle
Database Enterprise Edition with Partitioning Option, which must be
ordered separately from Oracle.

2)

The SUS contract runs for 1 year. The contract is automatically extended
by a further year unless canceled 3 months prior to expiration.

3)

B.Data expansions can also be used with B.Data V5.2 (SP1).

4)

The upgrades are delivered without Oracle Database Standard Edition
Embedded.

5)

The trial DVD can also be used to upgrade V5.3 SP1 -> V5.3 SP2.

Siemens ST 80 / ST PC · 2013

4/55

© Siemens AG 2013

HMI Software
Software for energy management
SIMATIC powerrate

■ Overview

■ Benefits
• Identification of energy-intensive equipment and processes to
develop measures for improving energy efficiency.
• Comparison of consumption profiles for more efficient
processes.
• Optimization of the company according to energy parameters,
based on an evaluation of consumption and costs.
• Compliance with the contractually agreed power limits, thus
preventing higher power supply costs or penalty payments.
• Integration of the 7KM PAC3200/4200 measuring devices for
a clear overview of selected measured values and alarms.
• Integration of switches with an overview of the switch status
and the switching possibilities.
• Accurate assignment and comparison of the consumption
data of specific work processes or batches

■ Design
SIMATIC powerrate, as an option for WinCC / PCS 7, ensures
transparency in energy consumption from the infeed to the load.

4

SIMATIC powerrate is used in all sectors in which WinCC or
PCS 7 are deployed and energy efficiency considerations play
a major role.
Total integration into WinCC or PCS 7 means that there is no
need for a special system environment. Predefined modules and
symbols give you the assurance of building on tested product
components, with interfaces that support customized
expansion.
SIMATIC powerrate therefore provides a solution that you can
use to obtain an overview of the energy consumption of a plant
easily and cost-effectively through integration in an existing
SIMATIC SCADA system.

4/56

Siemens ST 80 / ST PC · 2013

SIMATIC powerrate comprises the following components:
• Blocks for acquiring and conditioning energy data
• Faceplates for displaying and editing energy data
• Blocks for implementing load management (calculating the
trend, monitoring the limit, releasing/inhibiting loads), batchrelated consumption recording and for integrating measuring
instruments and switches
• Additional blocks – for example, for time synchronization, data
backup, data exchange with archives
• Faceplates for displaying results and entering values
(e.g. for configuration, or manually measured values)
• Excel-based reports for allocating energy data to cost
centers, for batch-related evaluation and for determining and
displaying the load duration curve
• Exporting data to Excel

© Siemens AG 2013

HMI Software
Software for energy management
SIMATIC powerrate

■ Function
Acquiring and conditioning energy data
Using ready-to-use function blocks, energy data can be
acquired by any PROFIBUS-capable devices. The data can be
input to the function blocks in the form of counter pulses, count
values or power values. Count values can also be entered
manually.
From this data, the function block calculates the power averages
and the work values for a predefined period. This calculated
data is subsequently saved in the WinCC archive. In addition,
a final value forecast is extrapolated for the power values for
each period.
A sample function (heat calculation) that can be adapted to the
needs of the customer at any time by means of open interfaces
has been implemented for the purpose of visualizing customized
calculations.
Data from manually read counters can be entered directly into
the system and used for further analysis. Absolute numerical
values (entry of an absolute value instead of the difference from
the previous value) can also be recorded and used in further
processing.
The up-to-date, acquired energy data is displayed as power
averages/work values for each time interval (total value for the
previous interval, current value of the current interval, extrapolated value for the end of the current interval). A load trend
display enables analysis of archived energy data as well as its
representation in tables.
The archived data can be exported to Excel directly from WinCC
using the export functions. The exported energy data can also
be included in further customized processing. WinCC tools can
be used to access the data from the WinCC archive.
For this purpose, selected energy data is read from archives
(Tag Logging archive, user archives) from the WinCC Runtime
database; using Microsoft Excel the following reports can then
be generated:
• Cost center report
Here the consumption can be allocated to different cost
centers and the costs can be calculated on the basis of
predefined tariffs. The results can be output by means of
2 reports in the form of tables or diagrams.
• Load duration curve
An analysis is carried out on the basis of the archived power
averages to establish how often a certain power average has
occurred in a given period. It can be quickly detected from
this characteristic curve whether temporary power peaks exist
which can represent a possible starting point for cost savings
by means of load management.
• Batch report
This is used to allocate consumption to batches, whereby the
data can be presented in chronological order or in order of
batch name.

The generation of exports or reports can be activated manually
or automatically time-controlled (daily, weekly or monthly). Data
access and report generation can also take place via a separate
"office" PC; which enables the WinCC installation and the "office"
applications to be distributed across different PCs.
Contractually agreed power limits (in the case of electricity,
normally the 15-minute average power value) must be observed,
otherwise significantly higher supply prices or even penalty
payments may become due to the energy supply company.
The load management feature of SIMATIC powerrate carries out
cyclic trend calculations in order to issue warnings/alarms if
violation of the limit is likely and to switch off loads in accordance
with the given configuration should this be required. If a limit is
exceeded despite this, the latest load management data is
archived to enable future evaluation or analysis.
To prevent unnecessary switching operations, numerous parameters are available for adapting the load management to the
current process conditions - and all this can be done easily and
conveniently via the faceplate.
For loads that are distributed over different PLCs, SIMATIC
powerrate contains appropriate PLC-to-PLC communication
blocks which can be used to integrate these loads into the load
management system. Load management is scalable, according
to the maximum number of loads to be integrated or monitored,
for up to 10, 25, 50, 75 or 100 loads. Load management can be
performed for different media (e.g. electricity, gas) simultaneously.
A batch comprises all the units of a product that have been
produced in one production cycle, i.e. under identical conditions. Batch-related consumption recording allows accurate
recording of energy consumption for each batch. Batch-related
consumption recording is possible for five types of energy each
with up to 10 loads. Appropriate reports can be generated for
analysis of the data (see also the batch report).
If the 7KM PAC3200/PAC4200 measuring devices are
integrated, selected measured values can be displayed and
alarms (current, voltage, pulse frequency too high) can be
generated from the digital status information and displayed.
Switch integration via digital inputs/outputs (DI/DO) supports
display of the switch status (On, Off, tripped, unplugged).
With the appropriate authorization, switching is also possible via
the faceplate. Switching takes place in a 2-step operation
(switch command is issued, followed by a prompt for repeated
confirmation; the switch command is not forwarded to the switch
until confirmation has been received).
Support for the WinCC Web Navigator option also makes the
powerrate functionality possible via the web.
To avoid data loss in the event of a communication fault, the data
is stored temporarily in a circulating buffer on the S7.

Siemens ST 80 / ST PC · 2013

4/57

4

© Siemens AG 2013

HMI Software
Software for energy management
SIMATIC powerrate

■ Technical specifications

■ Ordering data
SIMATIC powerrate V4.0 SP1

Hardware requirements
SIMATIC powerrate can be used in
the PCS 7 or WinCC SCADA environments. For installation, the respective
hardware requirements of the following
products apply:

• PCS 7
• STEP 7 and WinCC SCADA

Released CPUs - SIMATIC powerrate
is released in the PCS 7 environment
for

• S7-400 CPUs supported
by PCS 7
• WinAC RTX 2010

Released CPUs - SIMATIC powerrate
is released in the WinCC SCADA
environment for

• S7-400
• S7-300
- SIMATIC S7 CPU 319-3 PN/DP
V2.5 and higher
- SIMATIC S7 CPU 317-2 PN/DP
V2.6 and higher
- SIMATIC S7 CPU 315-2 PN/DP
V3.1 and higher
• SIMATIC ET 200S IM151-8 PN/DP
CPU V3.2 and higher
• WinAC RTX 2010

You can use SIMATIC powerrate in
the PCS 7 or WinCC SCADA environments. For installation, the respective
software requirements of the following
products apply:

• PCS 7
• STEP 7 and WinCC SCADA

The library is released for the following
PCS 7 versions

• SIMATIC PCS 7 V8.0 with
Update 1 (Europe & ASIA)
• SIMATIC PCS 7 V7.1 SP3

The library is released for the following
WinCC version with the corresponding
versions of STEP 7

• SIMATIC WinCC V7. 0 SP3,
SP3 with Update 1
(Europe & ASIA)

For use with WinCC V7.0 SP3, the
following installations are required

• WinCC minimum installation
- Basic Process Control
- User archives for load management and batch-oriented energy
acquisition
• WinCC add-on
"AS-OS Engineering"
For the use of SIMATIC powerrate
V4.0, WinCC must execute in
integrated mode with STEP 7.
• SIMATIC NET
• STEP 7

powerrate Reports has been released
for the following versions

• Microsoft Excel 2003
• Microsoft Excel 2007
• Microsoft Excel 2010

4/58

Order No.
6AV6372-1DE04-0AX0

Also included are
• License for user/archive
• PAC3200 function block library
for WinCC
• Block library PAC3200,
3WL/3VL for PCS 7
SIMATIC powerrate V4.0 SP1
upgrade

6AV6372-1DE04-0AX4

Upgrade V3.0 SP1 to V 4.0 SP1,
ES + OS-RT1)
SIMATIC powerrate V4.0 SP1
update

6AV6372-1DE04-0AX3

Update V4.0 to V 4.0 SP1
SIMATIC powerrate V4.0 SP1
trial license

6AV6372-1DE04-0AX7

Limited 30-day
ES + OS Runtime license
1)

Software requirements

4

SIMATIC powerrate V4.0 SP1 ES +
OS Runtime 1)

For operation on a WinCC/PCS 7 OS single-user workstation or server
and any number of automation systems. When using additional
WinCC/PCS 7 OS single-user stations/servers, one license is required
per WinCC/PCS 7 OS single-user station/server.

■ More information

Siemens ST 80 / ST PC · 2013

Further information can be found on the Internet at:
http://www.siemens.com/simatic-powerrate
Important information on the use of SIMATIC powerrate is
available on the Internet at:
http://support.automation.siemens.com/WW/view/en/48204134/
133200

© Siemens AG 2013

HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible HMI system

■ Overview
SIMATIC WinCC flexible ES engineering software
• Family of configuration systems with WinCC flexible Micro/
Compact/Standard/Advanced for SIMATIC operator panels,
the HMI part of SIMATIC C7 as well as for the PC-based visualization software WinCC flexible Runtime
• Runs under Windows XP Professional /
Windows 7 Professional, Ultimate, Enterprise
• Can be expanded by the option
"WinCC flexible /ChangeControl" for
version management and change logging

SIMATIC WinCC flexible Runtime visualization software
• Modular PC-based HMI solution for single-user systems
directly at the machine (further development of
ProTool/Pro RT)
• Runs under Windows XP Professional /
Windows 7 Professional, Ultimate, Enterprise
• Basic package for visualization, reporting and logging; can be
expanded by implementing option packages
• Flexible expansion possible with VB scripts and customized
ActiveX controls created with OPP (Open Platform Program)
• Can be integrated into automation solutions based on TCP/IP
networks
• Expanded service concepts with remote operation,
diagnostics and administration over the intranet and Internet
in combination with email communication

4

Siemens ST 80 / ST PC · 2013

4/59

© Siemens AG 2013

HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible ES

■ Overview

■ Application
SIMATIC WinCC flexible Micro/Compact/Standard/Advanced
are engineering tools for configuring SIMATIC HMI devices, the
operating component of SIMATIC C7 devices, the SIMOTION/
SINUMERIK Panel PCs as well as the PC-based visualization
system WinCC flexible Runtime.
Depending on the selected product, various target systems can
be configured:
WinCC flexible Micro
• Micro Panels: OP 73micro, TP 170micro, TP 177micro
WinCC flexible Compact

4

• Uniform family of engineering tools for configuration
SIMATIC HMI Operator Panels, the operator control part of
SIMATIC C7 units, SIMOTION/SINUMERIK Panel PCs as well
as the PC-based visualization software WinCC flexible
Runtime.
• Runs under Windows XP Professional /
Windows 7 Professional, Ultimate, Enterprise
• Current version:
- SIMATIC WinCC flexible 2008 SP3 Micro
- SIMATIC WinCC flexible 2008 SP3 Compact
- SIMATIC WinCC flexible 2008 SP3 Standard
- SIMATIC WinCC flexible 2008 SP3 Advanced

WinCC flexible Standard
In addition to the target systems that are configured using
WinCC flexible Compact:
• Mobile Panels: Mobile Panel 277
• 270 series Panels: TP 270, TP 277, OP 270, OP 277
• 270 series Multi Panels: MP 270B, MP 277
• 370 series Multi Panels: MP 370, MP 377
• C7 devices: C7-636 (Touch/Key)
WinCC flexible Advanced

■ Benefits
• The integrated configuration software reduces training,
maintenance and service overhead and protects the
customer's investments
• Minimized configuration overhead due to reuse of scalable
and dynamizable objects
• Tools for efficient and simple configuration:
- Wizard for defining the basic structure of the HMI project
- Table-based editors simplify the generation and processing
of similar types of object, e.g. for tags, texts, or alarms.
- Complex configuration tasks such as the definition of paths
of motion or the creation of the fundamental operator
prompting are simplified by means of graphical configuration.
• Comprehensive support of multi-language configurations for
worldwide use
- Selectable views for entering configuration data in several
languages
- System and user-specific text lexicons
- Export/import of language-dependent texts

4/60

In addition to the target systems that are configured using
WinCC flexible Micro:
• Basic Panels: KTP400 Basic, KTP600 Basic, KTP1000 Basic,
TP1500 Basic
• Mobile Panels: Mobile Panel 170, Mobile Panel 177
• 70 series Panels: OP 73, OP 77A, OP 77B
• 170 series Panels: TP 170A, TP 177A, TP 170B, TP 177B,
OP 170B, OP 177B
• 170 series Multi Panels: MP 177
• C7 devices: C7-635 (Touch/Key)

Siemens ST 80 / ST PC · 2013

In addition to the target systems that are configured using
WinCC flexible Standard:
• Standard PC
• SIMATIC Panel PC: Panel PC IL 70, Panel PC IL 77,
Panel PC 477/477B, Panel PC 577/577B, Panel PC 670,
Panel PC 677/677B, Panel PC 870, Panel PC 877
• SIMOTION Panel PC: P012K, P012T, P015K, P015T, PCR,
PCR-Touch
• SINUMERIK Panel PC: HT8, OP08T, OP010, OP012, TP012,
OP015, TP015, OP015A
For configuring panels released after the start of delivery of
WinCC flexible 2008, an HSP (Hardware Support Package)
is required that can be downloaded free of charge via the
following link:
http://www.siemens.com/wincc-flexible-hsp

© Siemens AG 2013

HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible ES

■ Design
The engineering tools of the SIMATIC WinCC flexible range are
based on one another. The available editors largely depend on
the respectively configured target systems and their functions.
A more comprehensive engineering tool such as WinCC flexible
Standard also offers the facilities of the smaller engineering
tools, e.g. WinCC flexible Compact or Micro.
Upgrading of a smaller engineering tool to a larger one is
possible using a Powerpack. An exception is WinCC flexible
Micro.
The scope of functions of the WinCC flexible engineering tools
already includes project support for the Runtime options
available for SIMATIC Panels or WinCC flexible Runtime,
independent of the RT licenses purchased. Separate licensing
is required for the target system in order to use the configured
Runtime options.

■ Function
Integration into automation systems
• Integration into SIMATIC STEP 7 V5.x and Simotion
- Management of HMI projects within the SIMATIC Manager
- Shared use of communication settings and process point
definitions, i.e., symbols and messages
- Display of the HMI configuring objects in the
SIMATIC Manager
- Transfer of configuring data via MPI/PROFIBUS/Ethernet
using routing
Configuration interface
• Comprehensive and fast access to editors and project data
via Workbench applications
• Adaptive user interface of engineering tools depending on
configured target system
• User-definable user interface settings, e.g., layout, toolbars,
object defaults
Project handling
• Device-independent configuration data can be used on a
variety of target systems without the need for conversion;
the interface adapts to the functional possibilities of the device
currently configured.
• Cross-device utilization of common configuration data
(e.g., text library) in multi-device projects
• Wizard-assisted definition of basic structure of HMI projects
(e.g., display layout, operator prompting)
Screen editor with extensive options for efficient and fast screen
configuration
• Generation of interconnected screen objects via Drag&Drop,
e.g., tags for the creation of input/output fields with process
interfacing or buttons with screen selection function
• Template for the definition of global screen objects and
functions (comparable with the Slide Master in
MS PowerPoint)
• User-friendly editor for the creation of image blocks with
defined external interface from screen objects
• Graphics-based configuration of motion paths
• Layer technology with up to 32 layers
• Tools for the Align, Rotate and Mirror functions

Import/export
• of texts for translation
• of tags, links, text lists, and messages
• Generation of variable lists for importing from controller
programming tools
Object-based data management with user-friendly search and
edit options
• Cross-reference list with direct access to all objects,
e.g. for editing or selection
• Search for objects in entire project
• Central reassignment of variables
• Text search and replace functions
Libraries for predefined/user-defined configuration objects
• Large number of scalable and dynamizable screen objects
included in scope of delivery
• Size-scalable WMF-format graphics for industrial applications
included in scope of delivery
• Preview function for library objects
• Storage of all engineering objects in library, e.g., blocks and
even entire displays or variables;
picture blocks can be created on a customer- or projectspecific basis by combining simple screen objects.
Changes to these picture blocks can be made centrally
(block definition).
Language support
• Multilingual project creation (max. 32 languages) in editors
thanks to selectable views
• Automatic translation on basis of system- and user-specific
dictionaries in central text library
• Central management of language-specific texts and graphics
in libraries
• Edit, export and import of texts for translation
• Language-specific graphics
Visual Basic Script support
• IntelliSense function for fast programming of access to
runtime objects
• Simple creation of control sequences in script code;
• Script debugging in Simulator and WinCC flexible Runtime
Test and startup support
• Simulation of HMI projects on engineering PC
• Jump to error cause based on alarm messages in the
Compiler
• Advanced ProSave service tool for all operating systems
supported by WinCC flexible
ChangeControl (option)
• Version management of project versions with rollback
• Logging of configuration changes,
e.g., for regulated industries
Note:
For further information, refer to "WinCC flexible options".
Default runtime data in engineering tools
• Users and passwords
• Recipe data records

Siemens ST 80 / ST PC · 2013

4/61

4

© Siemens AG 2013

HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible ES

■ Technical specifications
System requirements
(minimum requirements)

WinCC flexible
Engineering Software

Operating system

Windows XP Professional SP3
(32 bit),
Windows 7 Professional, Ultimate,
Enterprise (32 and 64 bit)
Additionally for
SIMATIC WinCC flexible Micro:
Windows XP Home SP3

Processor

Pentium 4 (or comparable) processor running at 1.6 GHz or faster

Resolution

1024 x 768 or higher

Main memory (RAM)

≥ 1 GB,
≥ 512 MB for WinCC flexible Micro

Hard disk (free memory space) 1)

≥ 2 GB 2)
≥ 1.2 GB for WinCC flexible Micro 3)

DVD drive

for software installation

■ Ordering data

4

6AV6610-0AA01-3CA8

WinCC flexible 2008 Compact
incl. SP3
Floating license, license key on USB
stick, software and documentation
on DVD, contains:
• Engineering software for configuring Micro Panels, Basic Panels
and 70/170 series Panels incl.
C7-635
• Software for
WinCC flexible /ChangeControl
engineering option 1)
• Simulation software for
Micro Panels, Basic Panels, and
70/170 series Panels incl. C7-635
• Native drivers

6AV6611-0AA51-3CA5

2)

When installing one language. An additional 200 MB are required for each
further language. In the case of different partitions for system and configuration: System partition approx. 700 MB, project partition approx. 1.3 GB.

3)

When installing one language. An additional 80 MB are required for each
further language. In the case of different partitions for system and configuration: System partition approx. 600 MB, project partition approx. 600 MB.

Order No.
WinCC flexible 2008 Advanced
incl. SP3
Floating license, license key on USB
stick, software and documentation
on DVD, contains:
• Engineering software for configuring WinCC flexible Runtime on
basic PCs/Panel PCs as well as
Micro Panels, Basic Panels and
70/170/270/370 series Panels incl.
C7-635/636
• Software for
WinCC flexible /ChangeControl
engineering option 1)
• Simulation software for
WinCC flexible Runtime as well
as Micro Panels, Basic Panels,
and 70/170/270/370 series Panels
incl. C7-635/636
• Native drivers

6AV6613-0AA51-3CA5

• Electronic documentation (.pdf)
WinCC flexible /ChangeControl
for WinCC flexible 2008
Compact/Standard/Advanced 1) 2)
Floating license, option, license key
only

• Electronic documentation (.pdf)
6AV6612-0AA51-3CA5

• Electronic documentation (.pdf)

1)

A separate license for WinCC flexible /ChangeControl must be purchased
for each engineering station

2)

The ChangeControl option has not been released for integrated operation
with STEP 7

4/62

In addition to the space needed by WinCC flexible, Windows also requires
space on the hard disk;
e.g. for the swap file. The following formula has proven itself in the past:
The size of the swap file = 3 x the size of available RAM.
For further information, refer to your Windows documentation

Order No.

WinCC flexible 2008 Micro
incl. SP3
Single license, without license key
software and documentation on
DVD, without license key, contains:
• Engineering software for configuration of Micro Panels
• Electronic documentation (.pdf)

WinCC flexible 2008 Standard
incl. SP3
Floating license, license key on USB
stick, software and documentation
on DVD, contains:
• Engineering software for configuring Micro Panels, Basic Panels
and 70/170/270/370 series Panels
incl. C7-635/636
• Software for
WinCC flexible /ChangeControl
engineering option 1)
• Simulation software for
Micro Panels, Basic Panels,
and 70/170/270/370 series Panels
incl. C7-635/636
• Native drivers

1)

Siemens ST 80 / ST PC · 2013

6AV6613-6AA01-3AB5

Powerpacks
SIMATIC WinCC flexible
Powerpacks
Single license, license key only
• WinCC flexible 2008 Standard
to 2008 Advanced
• WinCC flexible 2008 Compact
to 2008 Advanced
• WinCC flexible 2008 Compact
to 2008 Standard

6AV6613-2CD01-3AD5
6AV6613-2BD01-3AD5
6AV6612-2BC01-3AD5

Updates
WinCC flexible 2008
Micro Update 2008, 2008 SP1,
2008 SP2 -> 2008 SP3

6AV6610-0AA51-3CU8

WinCC flexible 2008
Compact/Standard/Advanced
Update 2008, 2008 SP1,
2008 SP2 -> 2008 SP3

6AV6613-0AA51-3CU8

© Siemens AG 2013

HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible ES

■ Ordering data

Order No.

Upgrades
SIMATIC WinCC flexible
2004/2005/2007
to SIMATIC WinCC flexible
2008 incl. SP3
• Upgrade to
WinCC flexible 2008 Micro 2)
• Upgrade to
WinCC flexible 2008 Compact,
incl. ChangeControl option 1)
• Upgrade to
WinCC flexible 2008 Standard,
incl. ChangeControl option 1)
• Upgrade to
WinCC flexible 2008 Advanced,
incl. ChangeControl option 1)
SIMATIC WinCC flexible ASIA
2004/2005/2007
to SIMATIC WinCC flexible ASIA
2008 incl. SP3
• Upgrade to
WinCC flexible 2008
ASIA Standard,
incl. ChangeControl option 1)
• Upgrade to
WinCC flexible 2008
ASIA Advanced,
incl. ChangeControl option 1)

6AV6610-0AA01-3CE8
6AV6611-0AA51-3CE5

6AV6612-0AA51-3CE5

6AV6613-0AA51-3CE5

6AV6613-0AA11-3CA5

• Electronic documentation (.pdf)
6AV6612-0AA11-3CE5

6AV6613-0AA11-3CE5

Versions for
China/Taiwan/Korea/Japan
WinCC flexible 2008 ASIA
Standard incl. SP3
Floating license, license key on USB
stick, software and documentation
on DVD, contains:
• Engineering software for configuring Micro Panels, Basic Panels
and 70/170/270/370 series Panels
incl. C7-635/636
• Simulation software for
Micro Panels, Basic Panels and
70/170/270/370 series Panels incl.
C7-635/636
• Native drivers

Order No.
WinCC flexible 2008 ASIA
Advanced incl. SP3
Floating license, license key on USB
stick, software and documentation
on DVD, contains:
• Engineering software for configuring WinCC flexible Runtime as well
as Micro Panels, Basic Panels and
70/170/270/370 series Panels incl.
C7-635/636
• Software for
WinCC flexible /ChangeControl
engineering option 1)
• Simulation software for
WinCC flexible Runtime as well
as Micro Panels, Basic Panels,
and 70/170/270/370 series Panels
incl. C7-635/636
• Native drivers

6AV6612-0AA11-3CA5

• Electronic documentation (.pdf)

Documentation
(must be ordered separately)
User Manual
WinCC flexible Communication
• German
• English
• French
• Italian
• Spanish

6AV6691-1CA01-3AA0
6AV6691-1CA01-3AB0
6AV6691-1CA01-3AC0
6AV6691-1CA01-3AD0
6AV6691-1CA01-3AE0

WinCC flexible Micro
User Manual
• German
• English
• French
• Italian
• Spanish

6AV6691-1AA01-3AA0
6AV6691-1AA01-3AB0
6AV6691-1AA01-3AC0
6AV6691-1AA01-3AD0
6AV6691-1AA01-3AE0

User Manual
WinCC flexible
Compact/Standard/Advanced
• German
• English
• French
• Italian
• Spanish

6AV6691-1AB01-3AA0
6AV6691-1AB01-3AB0
6AV6691-1AB01-3AC0
6AV6691-1AB01-3AD0
6AV6691-1AB01-3AE0

4

1)

A separate license for WinCC flexible /ChangeControl must be purchased
for each engineering station

2)

Original delivery note or Certificate of License (CoL) from previous
WinCC flexible Micro is required

■ More information
Additional information is available in the Internet under:
http://www.siemens.com/wincc-flexible

Note
Do you require a specific modification or extension to the
products described here? You will find information about the
Open Platform Program for the creation of user-specific
functions and controls for WinCC flexible under "Customized
Products".

Siemens ST 80 / ST PC · 2013

4/63

© Siemens AG 2013

HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible RT

■ Overview

■ Application
SIMATIC WinCC flexible Runtime is the high-performance visualization software for simple visualization tasks at machine level.
It can be used as a single-user solution for all automation applications in factory automation, process automation and building
services automation.

4

PC-based visualization software for single-user systems directly
at the machine.
• Runs under Windows XP Professional and
Windows 7 Professional, Ultimate, Enterprise
• Current version: SIMATIC WinCC flexible 2008 SP3 Runtime
SIMATIC WinCC flexible Runtime is configured with the
SIMATIC WinCC flexible Advanced configuration software.

■ Benefits
• Optimum price/performance ratio thanks to individually
scalable system functionality
• Functions for all visualization tasks:
Operator functions, graphical and trend displays, signaling
system, log system, archiving (option), recipe management
(option), Audit Trail (option), process fault diagnostics (option)
• Flexible runtime functionality thanks to Visual Basic scripts
• Innovative service concepts with remote operation,
diagnostics and administration via intranet and Internet as
well as e-mail communication to increase availability (option)
• Support for simple distributed automation solutions based on
TCP/IP networks at the machine level (option)

4/64

Siemens ST 80 / ST PC · 2013

SIMATIC WinCC flexible Runtime can be used in combination
with the following operator panels:
• SIMATIC Panel PCs
- PC IL 70/77
- Microbox 420
- Panel PC 477
- Panel PC 577
- Panel PC 670/677
- Panel PC 870/877
• SIMOTION Panel PCs
- P012, P015
- PCR, PCR-Touch
• SINUMERIK Panel PCs
- HT8; OP08T
- OP010, OP012, OP015
- TP012, TP015, OP015A
• Standard PCs with resolutions (W x H in pixels) of:
- 4:3 format: 640 x 480, 800 x 600, 1024 x 768, 1280 x 1024,
1600 x 1200
- Widescreen format: 800 x 480, 1280 x 800, 1366 x 768,
1440 x 900, 1680 x 1050, 1920 x 1080, 1920 x 1200,
1980 x 1080

■ Design
SIMATIC WinCC flexible Runtime is available as a software
package with 128, 512, 2048 or 4096 PowerTags. The term
PowerTags is used exclusively to identify process variables and
range pointers that have a process link to the controller.
Variables without process link, constant limit values of variables,
and messages (up to 4000 bit-triggered messages) are also
available for additional system performance.
The range of functions of WinCC flexible Runtime includes the
centralized HMI components for visualizing and reporting, and it
can be expanded to suit requirements and costs by using
optional packages.
SIMATIC WinCC flexible Runtime is configured with the
SIMATIC WinCC flexible Advanced configuration software.

© Siemens AG 2013

HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible RT

■ Function
Visualization via Windows-compliant operator interface
made up of parameterizable screen objects and image blocks
created on a project-specific basis:
• Numeric and alphanumeric input/output fields
• Static text and graphic display plus vector graphics
• Dynamizable graphics from HMI symbol library
• Bar graph, trend curve graph with scroll and zoom function as
well as read line
• Signal-specific text and graphic lists
• Buttons and switches for operator-process communication
• Editing fields for process values (signals)
• Analog display, slider as example for further screen objects
• Project-specific image blocks created from system basic
objects
• Graphic displays for various standard graphic formats,
e.g., bitmaps, .jpg, .wmf
Alarms and messages
• Discrete alarms and analog alarms as well as event-driven
Alarm-S/Alarm-D message procedure with SIMATIC S7 and
SIMOTION
• Freely-definable message classes for definition of acknowledgment response and display of message events
Logging of alarms and process values 1)
• Archiving in files (e.g. CSV or TXT file) and Microsoft SQL
databases
• Online evaluation of process value archives and alarm logs
• Evaluation of process value archives and alarm logs using
standard Microsoft tools such as Excel
Recipes 1)
• Generation of data records for machine or production data
• Display or entry of data records via a configurable screen
object or via process images when distributed within the
project
• Transmission of data records from or to the PLC
• Import/export for data records from/to CSV files
Documentation of process data, alarm events and recipes
• Time- or event-driven report output
• User-definable layout
Flexible expansion of system function
• thanks to Visual Basic Script
Language support for multilingual projects
• Up to 16 online languages (incl. Asian and Cyrillic)
• Language-dependent texts and graphics
• Language selection during runtime
User-oriented access protection according to requirements
of regulated sectors
• Authentication with user ID and password
• User-group-specific rights
• Central system-wide user administration based on
SIMATIC Logon 1)
• Monitoring of changes by operators in runtime operation 1)
• Recording of operator actions in an Audit Trail 1)

PLC link for a wide variety of PLCs on-board
• Simultaneous connection using several protocols: OPC Client
or SIMATIC HMI HTTP protocol are additive, i.e. can be used
in conjunction with other PLC links
• Communication via native drivers and standard OPC channel
Open communication between
HMI systems and with higher-level systems 1)
• OPC server
• Sm@rtAccess for communication between HMI systems
based on Ethernet networks, or via the intranet/Internet:
• Read and write access to variables;
WinCC flexible Runtime or SIMATIC Panels make data
(variables) available to other SIMATIC HMI systems or Office
applications.
• A SIMATIC HMI system can be used to control or monitor
another system remotely;
entry level for client/server configurations for distributed
operator stations or for solutions with headend or control
room.
Sm@rtService for remote control,
diagnostics and administration via intranet and Internet 1)
• Display and control of process images on remote PC or Panel
• Sending of e-mails on demand or event-driven
• System diagnostics visualized via device-specific HTML
pages
1)

Option for SIMATIC WinCC flexible Runtime; runtime licenses
must be purchased separately. For further information, refer to
"WinCC flexible options".

System requirements

WinCC flexible Runtime

Operating system

Windows XP Professional SP3
(32 bit)
Windows XP Embedded 1)
Windows 7 Professional / Ultimate /
Enterprise (32 bit and 64 bit)

Processor 4)
• Minimum

Windows XP: 300 MHz
Windows 7: 1 GHz
Windows XP: ≥ Pentium III, 500 MHz
Windows 7: ≥ 1 GHz

• Recommended
Graphics
• Minimum
• Resolution

SVGA
640 x 480 to 1600 x 1200 or
800 x 480 to 1980 x 1080

RAM 2)
• Minimum

Windows XP: 128 MB
Windows 7: 1 GB
Windows XP: ≥ 512 MB
Windows 7: ≥ 1 GB

• Recommended
Hard disk (free memory space) 3)

≥ 250 MB

1)

Only for enabled platforms (e.g. Panel PC 477).
You can get information from your Siemens contact.

2)

RAM requirements are determined primarily by the size of the graphics
used.

3)

Without taking archives into account.
In addition to the space needed by WinCC flexible, Windows also requires
space on the hard disk; e.g., for the swap file. The following formula has
proven itself in the past: The size of the swap file = 3 x the size of the RAM.
For further information, refer to your Windows documentation

4)

More powerful systems (Pentium 4 and higher) may be required in order to
use options

Siemens ST 80 / ST PC · 2013

4/65

4

© Siemens AG 2013

HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible RT

■ Integration
SIMATIC WinCC flexible Runtime supports linking to:
Protocol

PC interfaces

SIMATIC S5 via AS511 (TTY)
COM1/COM2 13)

S5-90U

SIMATIC 500/505 RS 232/RS 422

S5-90U

SIMATIC 505 via PROFIBUS DP

S5-100U (CPU 100, 102, 103)

SIMATIC 545/555 with CP 5434

S5-115U
(CPU 941, 942, 943, 944, 945)

SIMOTION 8)

S5-135U (CPU 928A, 928B)

SINUMERIK 9)

S5-155U (CPU 946/947, 948)
SIMATIC S5 via PROFIBUS DP

S5-115U
(CPU 941, 942, 943, 944, 945)

CP 5512 2)
CP 5611 A2 2)

S5-135U (CPU 928A, 928B)
S5-155U (CPU 946/947, 948)
SIMATIC S7 via PPI
CP 5512 2)
CP 5611 A2 2)
CP 5621 1)
CP 5613 A2
CP 5614 A2
PC/PPI adapter 3)

S7-200

SIMATIC S7 via MPI
S7-200 (except CPU 212) 4)
S7-300
S7-400
WinAC Basis (V3.0 and higher)
WinAC RTX

CP 5512 2)
CP 5611 A2 2)
CP 5621 1)
CP 5711 2)
CP 5613 A2
CP 5614 A2
PC adapter USB 6)
Teleservice V6.1

SIMATIC S7 via PROFIBUS DP 5)
S7-215 4)
S7-300 CPUs
with integr. PROFIBUS interface
S7-300 with CP 342-5

CP 5512 2)
CP 5611 A2 2)
CP 5621 1)
CP 5711 2)
CP 5613 A2
CP 5614 A2

S7-400 CPUs
with integr. PROFIBUS interface

WinAC Basis (V3.0 and higher)

CP 5512 2)
CP 5611 A2 2)

COM1/COM2

Allen Bradley (Ethernet)

CP 1612 7)

GE Fanuc (SNP/SNPX)

COM1/COM2

LG GLOFA GM

COM1/COM2

Mitsubishi (FX/MP4)

COM1/COM2

Modicon (Modbus)

COM1/COM2

Modicon (Modbus TCP/IP)

CP 1612 7)

OMRON (Link/Multilink)

COM1/COM2

OPC 10) 12)
Data Access V2.05a (client + server)

SIMATIC S7 via Ethernet (TCP/IP)
S7-200 with CP 243-1
S7-300 CPUs
with integral Ethernet interface

CP 1612 7)
CP 1613 A2

S7-300 with CP 343-1
S7-400 CPUs
with integral Ethernet interface

CP 1612 7)

Data Access XML V1.00 (client)
HTTP communication for data
exchange between SIMATIC HMI
(client + server) 11) 12)

CP 1612 7)

1)

WinCC flexible Runtime is passive (DP slave); the function block required
for the link is included in the scope of delivery of WinCC flexible

2)

For Microbox 427 and Panel PC 477/577/677 via internal MPI/DP interface

3)

Only point-to-point to S7-200; no configuration download, operating
systems: Windows 2000/XP; Order number: 6ES7 901-3CB30-0AX0

4)

Constraint with regard to baud rate for S7-200; see Catalog ST 70

5)

WinCC flexible RT is active; communication with S7 functions

6)

Only point-to-point to S7-300/-400; No configuration download, operating
systems: Windows 2000/XP; order number: 6ES7 972-0CB20-0XA0 (USB)

7)

For Microbox 427 and Panel PC 477/577/677/877 via internal Ethernet
interface

8)

For further information, see Catalog PM 10

9)

"SINUMERIK HMI copy license OA" option required; for further information,
see Catalog NC 60

10)

OPC Client is included in scope of delivery,
the "WinCC flexible /OPC Server for WinCC flexible Runtime" license is
required for the OPC Server option

11)

"WinCC flexible /Sm@rtAccess for WinCC flexible Runtime" license
required

12)

OPC and HTTP communication are additive, i.e. can be used in
conjunction with the PLC links listed above

13)

Via PC cable with integrated level converter RS 232/TTY;
Order number: 6ES5 734-1BD20

WinAC RTX

For information about SIMATIC Panels that support OPC/http
communication, see the overview under "System interfaces".

S7-400 with CP 443-1
WinAC Basis (V3.0 and higher)
WinAC RTX
SIMATIC S7 via integrated interface
Internal system interface

WinAC RTX

4/66

COM1/COM2

Allen Bradley (DF1/DH485)

S7-400 with CP 443-5 or IM 467

WinAC Basis (V2.0 and higher)

PC interfaces

Third-party controllers
1)

S5-95U/L2-DP master

4

Protocol
SIMATIC 505 NITP

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible RT

■ Integration (continued)
Application note
In parallel with each and every PLC link, WinCC flexible Runtime
supports the use of the OPC Client channel; this enables, for
example, connection to an SNMP OPC Server for the purpose of
visualizing the data stored there.

Note:
For further information, see "HMI devices/System interfaces"

The SNMP OPC Server provides a means of monitoring network
components of any type (e.g. switches) which support the SNMP
protocol. For further information, see Catalog IK PI.
Higher level visualization system

OPC Client

Industrial Ethernet
On-site visualization

OPC Server

OPC Server

4
OPC Client

SIMATIC S7-300

SIMATIC S7-400

3rd party
OPC Server
Non-Siemens
PLCs

G_ST80_XX_00077

PROFIBUS

SIMATIC WinCC flexible Runtime application example

Siemens ST 80 / ST PC · 2013

4/67

© Siemens AG 2013

HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible RT

■ Technical specifications
Type

4

SIMATIC WinCC flexible Runtime

Type

SIMATIC WinCC flexible Runtime

The specifications are
maximum values

Password protection
• User rights
• Number of user groups

32
50

Visual Basic scripts

200

Online languages, max.

16

Displays
• Fields per screen
• Variables per screen
• Static text
• Graphics objects
• Complex objects per display
(e.g. bars)
• Trends
• Graphics lists 1)
• Text lists 1)
• Number of entries in symbol tables

500
400
400
30,000
2,000
40

Variables

4,096 3)

Messages bit-triggered / analog
• Message text (number of characters)
• Number of process values per message
• Size of message buffer
• Pending message events

4,000 / 500
80
8

Archives 4)
• Archivable data

100
Process data,
messages
500,000

• Max. number of entries per archive
(incl. all archive segments)
• Archive types

800
500
500
3,500

1,024
500

• Data storage format

Short-term archive, sequence
archive (max. 400 per archive)
CSV (Comma Separated Variable),
RDB (Runtime Data Base),
interface to MS SQL database

Recipes 4)
• Elements per recipe
• Data records per recipe

1,000
2,000 3)
5,000 2)

4/68

Siemens ST 80 / ST PC · 2013

Communication
SIMATIC S7 MPI interface/
PROFIBUS DP interface
• Number of connectable stations,
max.

Depending on the scope of the
configuration (communication) from
the point of view of WinCC flexible
Runtime, as many as 8 connections
are possible

SIMATIC S7 PPI interface
• Number of connectable stations,
max.

1 from viewpoint of
WinCC flexible Runtime

SIMATIC S5
PROFIBUS DP interface
• Number of connectable stations,
max.

1 from viewpoint of
WinCC flexible Runtime

Multi-protocol operation

Yes, OPC Client or SIMATIC HMI
HTTP protocol are additive, i.e. can
be used in conjunction with other
PLC links

1)

Together only 500 text and graphics lists

2)

Dependent on memory medium used

3)

Dependent on number of licensed PowerTags

4)

Option for SIMATIC WinCC flexible Runtime.
For further information, refer to "WinCC flexible options".

© Siemens AG 2013

HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible RT

■ Ordering data
SIMATIC WinCC flexible 2008
Runtime
for PC systems;
incl. SW for PC systems options 1)
Single license,
on CD-ROM incl. licensing, for:
• 128 PowerTags (RT 128)
• 512 PowerTags (RT 512)
• 2048 PowerTags (RT 2048)
• 4096 PowerTags (RT 4096)

Order No.

6AV6613-1BA51-3CA0
6AV6613-1DA51-3CA0
6AV6613-1FA51-3CA0
6AV6613-1GA51-3CA0

Powerpacks
SIMATIC WinCC flexible 2008
Runtime
Single license, only license key
for PowerTags, from
• 128 to 512 PowerTags
• 128 to 2048 PowerTags
• 512 to 2048 PowerTags
• 128 to 4096 PowerTags
• 512 to 4096 PowerTags
• 2048 to 4096 PowerTags

6AV6613-4BD01-3AD0
6AV6613-4BF01-3AD0
6AV6613-4DF01-3AD0
6AV6613-4BG01-3AD0
6AV6613-4DG01-3AD0
6AV6613-4FG01-3AD0

Updates
SIMATIC WinCC flexible 2008
Runtime
Update 2008, 2008 SP1, 2008 SP2
-> 2008 SP3

Order No.
Documentation
(must be ordered separately)

6AV6613-1XA51-3CU8

User Manual
WinCC flexible Runtime
• German
• English
• French
• Italian
• Spanish

6AV6691-1BA01-3AA0
6AV6691-1BA01-3AB0
6AV6691-1BA01-3AC0
6AV6691-1BA01-3AD0
6AV6691-1BA01-3AE0

User Manual
WinCC flexible Communication
• German
• English
• French
• Italian
• Spanish

6AV6691-1CA01-3AA0
6AV6691-1CA01-3AB0
6AV6691-1CA01-3AC0
6AV6691-1CA01-3AD0
6AV6691-1CA01-3AE0

SIMATIC HMI Manual Collection
Electronic documentation, on DVD

6AV6691-1SA01-0AX0

5 languages (English, French,
German, Italian and Spanish);
contains: all currently available
user manuals, device manuals
and communication manuals for
SIMATIC HMI

4

Upgrades
SIMATIC WinCC flexible
2004/2005/2007 Runtime
to SIMATIC WinCC flexible 2008
Runtime
• Upgrade to
SIMATIC WinCC flexible Runtime
2008 PowerTags
incl. Runtime Options for:
- WinCC flexible /Archives

6AV6613-1XA51-3CE0

- WinCC flexible /Recipes
- WinCC flexible /Audit
- WinCC flexible /Sm@rtAccess
- WinCC flexible /Sm@rtService
- WinCC flexible /OPC server
- WinCC flexible /ProAgent
• Upgrade of the SIMATIC
WinCC flexible Panel options:
- WinCC flexible /Audit
for SIMATIC Panel
- WinCC flexible /Sm@rtAccess
for SIMATIC Panel
- WinCC flexible /Sm@rtService
for SIMATIC Panel
- WinCC flexible /OPC server
for SIMATIC Multi Panel
- WinCC flexible /ProAgent
for SIMATIC Multi Panel

6AV6618-7XX01-3AF0

1)

Runtime licenses for WinCC flexible Runtime options must be purchased
separately for each target system.

Siemens ST 80 / ST PC · 2013

4/69

© Siemens AG 2013

HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible RT

■ Ordering data

Order No.

Communication
via Industrial Ethernet
CP 1613-A2
PCI card (32-bit) for connecting
a PG/PC to Industrial Ethernet
(communications software must
be ordered separately)
SIMATIC NET IE S7-1613 V8.0 SP1
Software for S7 and open communication, incl. PG/OP communication,
OPC server and NCM PC; up to
120 connections, Runtime software,
software and electronic manual on
CD-ROM, license key on USB flash
drive, Class A, for 32-bit Windows 7
Professional/Ultimate for up to
4 CP 1613/CP 1613 A2 / CP 1623;
English/German
• Single license for 1 installation
• Software Update Service for one
year, with automatic extension;
requirement: Current software
version
• Upgrade S7-1613 from V6.4 to
S7-1613 V8.0 SP1
• Upgrade S7-1613 from V6.0, V6.1,
V6.2 or V6.3 to S7-1613 V8.0 SP1

4

6GK1161-3AA01

6GK1716-1CB80-3AA0
6GK1716-1CB00-3AL0

6GK1716-1CB00-3AE0
6GK1716-1CB00-3AE1

Communication via PROFIBUS
CP 5613-A2
PCI card (32-bit) for connecting a
PC to PROFIBUS (communications
software must be ordered separately)

6GK1561-3AA01

CP 5614-A2
PCI card (32-bit) for connecting a
PC to PROFIBUS (communications
software must be ordered separately)

6GK1561-4AA01

■ More information
Additional information is available in the Internet under:
http://www.siemens.com/wincc-flexible
Note
Do you need a specific modification or option for the products
described here? You will find information about the Open
Platform Program for the creation of user-specific functions and
controls for WinCC flexible under "Customized Products".

4/70

Siemens ST 80 / ST PC · 2013

Order No.
SIMATIC NET PB S7-5613 V8.0
SP1
Software for S7 communication, incl.
PG and FDL protocol, OPC server
and NCM PC; Runtime software,
software and electronic manual on
USB flash drive, license key on diskette, Class A, for 32-bit Windows 7
Professional/Ultimate for up to
4 CP 5613 A2, CP5614 A2,
CP 5603 / CP 5623 / CP 5624;
• Single license for 1 installation
• Software Update Service for one
year, with automatic extension;
requirement: Current software
version
• Upgrade S7-5613 from V6.4 to
S7-5613 V8.0 SP1
• Upgrade S7-5613 from V6.0, V6.1,
V6.2 or V6.3 to S7-5613 V8.0 SP1

6GK1713-5CB80-3AA0
6GK1713-5CB00-3AL0

6GK1713-5CB00-3AE0
6GK1713-5CB00-3AE1

CP 5512
PCMCIA card (32-bit CARDBUS)
for connecting a PG/Notebook to
PROFIBUS or MPI
(communications software
included in WinCC flexible).

6GK1551-2AA00

CP 5611-A2
PCI card (32-bit) for connecting
a PG/PC to PROFIBUS
(communications software included
in WinCC flexible basic package)

6GK1561-1AA01

CP 5611 MPI
Comprising CP 5611 A2 (32-bit)
and MPI cable, 5 m

6GK1561-1AM01

CP 5621
PCI Express X1 card (32-bit) for
connection of PG/PC to PROFIBUS
or MPI (communications software
included in WinCC flexible basic
package)

6GK1562-1AA00

CP 5711
USB adapter (USB V2.0) for
connecting a PG or Notebook to
PROFIBUS or MPI (2 m USB cable
and 5 m MPI cable included)

6GK1571-1AM00

PC/PPI adapter
RS 232, 9-pin; male with RS 232/PPI
converter, max. 19.2 kbps

6ES7901-3CB30-0XA0

PC adapter USB
For use with Windows 2000/XP

6ES7972-0CB20-0XA0

© Siemens AG 2013

HMI Software
SIMATIC WinCC flexible options
SIMATIC WinCC flexible options

■ Overview
Option for SIMATIC WinCC flexible Engineering

SIMATIC Logon for WinCC flexible

SIMATIC WinCC flexible /ChangeControl

Option for connecting PCs with SIMATIC WinCC flexible Runtime
and SIMATIC Panels to central user administration.
• Creates user administration on a central computer to which
one or more WinCC flexible stations can be connected over
Ethernet.
• With each logging-on/off of a user on one of the connected
stations, SIMATIC Logon checks whether a user password has
been created and that the required privileges exist.
• SIMATIC Logon for WinCC flexible supports the user in combination with the /Audit and /ChangeControl options in meeting
requirements in accordance with FDA 21 CFR Part 11 and
EU178.

WinCC flexible/ChangeControl enables consistent backup of
configuration data. The history of changes can be verified down
to the last detail for applications requiring interruption-free proof
for the complete life cycle of a product.
• Delivered customer projects, approved reference states or
development stages are managed in a database.
• Changes to project data can be integrated without problem
into the version management using new versions.
• A rollback is possible at any time.
SIMATIC WinCC flexible /Archives
Archiving of alarms and process values
• Archiving in files (e.g. CSV file) and Microsoft SQL databases
• Online evaluation of process value archives and alarm logs
• Evaluation of process value archives and alarm logs using
standard MS tools such as Excel
SIMATIC WinCC flexible /Recipes
Generation and management of data records for machine or
production data
• Display or entry of data records via a configurable screen
object or via process images when distributed within the
project
• Transmission of data records from or to the controller
• Import/export of data sets as CSV files
SIMATIC WinCC flexible /Audit
Recording of operator actions in an Audit Trail
• Electronic signature for important operator actions relevant to
production
• The ChangeControl option supports users in respect of
tracking modifications to projects.
• Audit supports users in meeting special quality requirements,
e.g.
- Production plant requiring validation according to
21 CFR Part 11 (Food Drug Administration law)
- In respect of traceability according to EU 175/2002
(EU directive)

SIMATIC WinCC flexible /Sm@rtAccess
• Flexible solution for access to HMI systems and process data
from any location
• Communication between different SIMATIC HMI systems
SIMATIC WinCC flexible /Sm@rtService
• Remote maintenance and servicing of machines and plant via
Internet/intranet
• Reduced downtimes for machines and plant with direct
remote access
• Flexible solution for remote access to machines and plant
SIMATIC WinCC flexible /OPC Server
• Incorporation of automation components from different
vendors into a single automation concept
• Communication for data exchange between HMI systems
and/or higher-level control system
• Communication with applications from different vendors,
e.g. MES, ERP or applications in the office sector
SIMATIC WinCC flexible /ProAgent
• Precise and rapid process fault diagnostics in plant and
machines for SIMATIC S7 and SIMATIC HMI
• Standardized diagnostics concept for various SIMATIC
components
• No further configuration overhead for diagnostics functionality
• Frees up PLC capacity with regard to memory and program
execution time

Siemens ST 80 / ST PC · 2013

4/71

4

© Siemens AG 2013

HMI Software
SIMATIC WinCC flexible options
WinCC flexible /ChangeControl

■ Overview

■ Application
• In machine/special machine construction for project
management, e.g. delivered customer versions and their
modifications
• For saving of intermediate states during complex new developments or expansions, with rollback facility
• During work for specific orders as basis for calculating costs
for modifications
• In regulated sectors as proof of state of plants or machines
and any modifications made to them

■ Function
• Integral GUI for management of project versions (version tree
with main line and secondary lines for modified project
versions)
• Modification log can be activated/deactivated and shows who
carried out modifications, and when/which. Modification
reasons can be entered as comments

■ Ordering data

4

• Options for the versioning of configuration data and for tracing
configuration changes (e.g. as verification in regulated
sectors)
• For the engineering tool SIMATIC WinCC flexible
Compact/Standard/Advanced
• One license is required for each configuration computer

1)

6AV6613-6AA01-3AB5

The ChangeControl option has not been released for integrated operation
with STEP 7.

■ More information

■ Benefits
• Consistent backup of configuration data
- Delivered versions, approved reference states or development stages are managed in a database.
- Changes to project data can be integrated without problem
into the version management using new versions. A rollback
is possible at any time.
• Tracing of configuration changes
- The history of changes can be verified down to the last detail
for applications requiring interruption-free proof for the
complete life cycle of a product.

4/72

WinCC flexible /ChangeControl
for WinCC flexible 2008
Compact/Standard/Advanced 1)
Floating License, option,
license key only

Order No.

Siemens ST 80 / ST PC · 2013

Note
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about the Open Platform Program
for the creation of user-specific functions and controls for
WinCC flexible.

© Siemens AG 2013

HMI Software
SIMATIC WinCC flexible options
WinCC flexible /Archives

■ Overview

■ Function
• Time-controlled as well as manual or process-controlled
swapping out of process data and messages for long-term
archiving
• During runtime, swapped out data are read in and selectively
analyzed using WinCC flexible Runtime
- Presentation and evaluation of archived process data based
on a configurable trend display. Reading of the values is
facilitated by a read line.
- Presentation and evaluation of archived alarms based on a
configurable alarm view.
- User-friendly navigation in the archives
• External evaluation of the archives using MS standard tools
• Various archive types are supported: sequence and shortterm archives
• Archiving of process values and messages on external,
Windows-supported storage media
- CSV files
- RDB files
- Microsoft SQL server via ODBC
• Power standard functions permit user-friendly and flexible
utilization of the archives

• Option for SIMATIC WinCC flexible Runtime for archiving
process values and messages
• Archiving of process values and messages supports the
acquisition and processing of process data from an industrial
plant or machine. Evaluation of the archived process data
provides information about the operating states of the plant or
machine
• One license is required per operator station
(no license is required for SIMATIC Panels/Multi Panels)

■ Benefits
• Message and process value archives permit foresighted
diagnostics which prevents downtimes
• Early detection of danger or fault states
• Increase in product quality and productivity thanks to regular
evaluation of process value and message archives

■ Technical specifications
Type

WinCC flexible /Archives
The specifications are maximum
values

Execution platform

SIMATIC WinCC flexible Runtime

Archives
• Archivable data
• Cyclical trigger for archiving process
values (variables)
• Max. number of entries per archive
(incl. sequence archive)
• Archive types

100
Process values, messages
1s

Further use of archives for evaluation and long-term archiving
Record of repeated fault states
Optimization of maintenance cycles
Ensured quality standards
Control of quality as well as production capacity utilization
Documentation of process sequence

• Data storage format

1)

• Circulating archive
• Sequence archive
(max. 400 per archive)
CSV (Comma Separated Variable),
RDB (Runtime Data Base) and
interface to Microsoft SQL database (database not included in
scope of delivery)

■ Application
•
•
•
•
•
•

500,000 1)

Dependent on memory medium used

■ Ordering data

Order No.

WinCC flexible /Archives for
WinCC flexible 2008 Runtime 1)
Single License, license key only

6AV6618-7ED01-3AB0

WinCC flexible /Archives+
Recipes for WinCC flexible 2008
Runtime 1)
Single License for each option,
license key only

6AV6618-7GD01-3AB0

1)

One license is required for each operator station. A license is not required
for the engineering system for configuring the runtime option.

■ More information
Note
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about the Open Platform Program
for the creation of user-specific functions and controls for
WinCC flexible.

Siemens ST 80 / ST PC · 2013

4/73

4

© Siemens AG 2013

HMI Software
SIMATIC WinCC flexible options
WinCC flexible /Recipes

■ Overview

■ Function
• Input of data sets (e.g. operating parameters for a machine,
production data for a plastics processing machine) in
WinCC flexible Runtime, their storage, and passing on to the
PLC
• Display and input of data sets using a configurable graphics
object, or distributed among several process displays within
the project
• Data set elements are coupled to the process using direct
linking of the variables
• Transmission of data records from or to the PLC
• Powerful interfaces permit synchronized exchange of data
with the PLC
• Saving of data sets on local media or on remote data servers
via networks
• Import/export of data sets as CSV files
• Logging of data sets, e.g. as batch report/shift report
• Convenient and flexible management of data sets using
powerful standard functions

4

• Option for SIMATIC WinCC flexible Runtime for managing data
records in recipes that contain related machine or production
data
• The data in a data set can be transferred, for example, from
the control unit to the PLC to switch production to a different
product variant
• One license is required per operator station (no license is
required for SIMATIC Panels/Multi Panels)

■ Benefits

WinCC flexible recipes and the associated data sets are conveniently created using a separate editor in the WinCC flexible
Advanced engineering tool, and assigned default data.
A configurable table object is used to display the data during
runtime. Furthermore, the individual data set elements can also
be directly output for several process displays on the basis of
standard input/output boxes. The data can therefore be clearly
presented for the operator in technological layers.

■ Technical specifications
Type

• Generation and management of machine parameters and
production data on the basis of data sets, and exchange with
the automation equipment, e.g. with the machine
• Clear tabular representation of data elements with support of
a configurable graphic object, or representation in technical
relationships for several process graphics
• Simple operator prompting using standard functions
• Export/import of data sets for further processing with other
tools (e.g. MS Excel)

■ Application
• Assignment of plant/machine parameters in the production
industry
• Batch-oriented production, e.g. in the food or plastics industry

WinCC flexible /Recipes
The specifications are maximum
values

Execution platform

SIMATIC WinCC flexible Runtime

Recipes
• Entries per recipe
• Data records per recipe
• User data length in bytes
per data record

1000
2000 1)
5000 2)
8000 KB 2)

1)

Dependent on number of licensed PowerTags

2)

Dependent on memory medium used

■ Ordering data

Order No.

WinCC flexible /Recipes for
WinCC flexible 2008 Runtime 1)
Single License, license key only

6AV6618-7FD01-3AB0

WinCC flexible /Archives+Recipes
for WinCC flexible 2008 Runtime 1)
Single License for each option,
license key only

6AV6618-7GD01-3AB0

1)

One license is required for each operator station.
A license is not required for the engineering system for configuring the
Runtime option.

■ More information
Note
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about the Open Platform Program
for the creation of user-specific functions and controls for
WinCC flexible.

4/74

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

HMI Software
SIMATIC WinCC flexible options
WinCC flexible /Audit

■ Overview

■ Benefits
• Audit supports the user in meeting special quality requirements, e.g.,
- production plant requiring validation according to 21 CFR
Part 11 FDA 2)
- in respect of traceability according to EU 175/2002 3)
• Entries in the audit trail are allocated to individual users.
This ensures that responsibilities can be clearly identified.
• The audit trail, stored as a CSV file 1), can be checked via a
security mechanism to find out if subsequent changes have
been made.
• For particularly important user actions, e.g., starting
production or loading new recipes, electronic signatures and
comments can be configured and then called up and logged
during runtime.

• Option for SIMATIC WinCC flexible Runtime as well as
SIMATIC Panels for recording operations in an audit trail, and
electronic signature
• The audit trail features a safety mechanism that indicates
subsequent manipulation.
• An easy-to-use configuration option included as standard in
WinCC flexible enables you to set:
- The operator actions to be recorded in the audit trail during
runtime
- The important operator actions requiring electronic
signature/comments during runtime
• The audit option combined with the WinCC flexible ES
ChangeControl option supports the user with plant validation
• Available for the following SIMATIC HMI systems:
TP/OP 270, TP/OP 277, MP 270B, MP 277, MP 370, MP 377,
WinCC flexible Runtime
• A license is required for every operator control unit
(panel or PC)

1)

CSV Comma Separated Values

2)

The FDA (Food and Drug Administration) is the American public health
authority

3)

21 CFR Part 11- law on plant validation

■ Technical specifications
WinCC flexible /Audit
• Plug-in flash memory card on the
panel

Archive for Audit Trail use
on the Panel

• In the higher-level PC (memory
medium) connected to the panel
via Ethernet
On the PC (storage medium)

Archive for Audit Trail use of
WinCC flexible Runtime
Execution platform
SIMATIC Panels

Mobile Panel 277, TP/OP 270,
TP/OP 277

SIMATIC Multi Panels

MP 270B, MP 277, MP 370, MP 377

PCs

SIMATIC WinCC flexible Runtime

■ Ordering data

Order No.

WinCC flexible /Audit for
SIMATIC Panels
Single license, license key only

6AV6618-7HB01-3AB0

WinCC flexible /Audit for
WinCC flexible Runtime 2008
Single license, license key only

6AV6618-7HD01-3AB0

■ More information
Note
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about the Open Platform Program
for the creation of user-specific functions and controls for
WinCC flexible.

Siemens ST 80 / ST PC · 2013

4/75

4

© Siemens AG 2013

HMI Software
SIMATIC WinCC flexible options
SIMATIC Logon for WinCC flexible

■ Overview

■ Design
SIMATIC Logon and SIMATIC Logon Remote Access are
installed on a central station.
The following WinCC flexible stations are connected to the
central station via Ethernet network:
• PCs with WinCC flexible Runtime
• SIMATIC Panels from the 177 series or higher
(panels with Ethernet interface)
Licensing
The following licenses are required:
• SIMATIC Logon basic license
• SIMATIC Logon Remote Access license (3-pack license
10-pack license); more than one SIMATIC Logon Remote
Access license can be installed.

4

• Option for connecting PCs with SIMATIC WinCC flexible
Runtime and SIMATIC Panels to central user administration.
• Creates user administration on a central computer to which
one or more WinCC flexible stations can be connected over
Ethernet.
• With each logging-on/off of a user on one of the connected
stations, SIMATIC Logon checks whether a user password has
been created and that the required privileges exist.
• SIMATIC Logon for WinCC flexible supports the user in combination with the /Audit and /ChangeControl options in meeting
requirements in accordance with FDA 21 CFR Part 11 and
EU178.
• Licensing:
SIMATIC Logon (basic license) and SIMATIC Logon Remote
Access (3-pack license) for connection of 3 WinCC flexible
stations to a central user administration. Additional stations
can be connected by using further SIMATIC Logon Remote
Access licenses (3-pack/10-pack).

■ Benefits
• Centralized configuration of all access authorizations of a
distributed system avoids unnecessary travel times. Timeconsuming multiple configurations for each individual local
station become unnecessary. Accordingly, users can be
easily configured from a central location.
• All access data apply throughout the plant on every
connected station. Additional access data on local
subsystems is no longer necessary.

The number of connectable stations depends on the
SIMATIC Logon Remote Access licenses used. This number is
the total of the connections provided by the individual licenses.
As an example: Two installed licenses for 10 enable the
connection of 20 stations to the central station.

■ Function
Configuration
In the first step, the following data must be saved in the user
administration of WinCC flexible on every WinCC flexible station
in the plant:
• Required user groups with associated user privileges
• IP address, port number, Windows domain of the central
station on which the central user administration is stored.
All user groups are configured with the same names in the
central user administration. All users are created here, and have
automatic access to the connected WinCC flexible stations in
accordance with the relevant user group.
If the connection fails between the central station with
SIMATIC Logon and a WinCC flexible station, the operation is
handled through an "emergency user" which must first be
preconfigured locally.
Intervals for password aging and regulations for the structure of
a password are defined according to the configuration on the
central station and then also apply to all decentrally connected
WinCC flexible stations or the respective users.

■ Technical specifications
SIMATIC Logon for
WinCC flexible
Execution platform

4/76

Siemens ST 80 / ST PC · 2013

SIMATIC Panels

Mobile Panel 177 PN;
Mobile Panel 277,
TP/OP 177B PN/DP, TP/OP 277

SIMATIC Multi Panels

MP 177, MP 277, MP 377

PCs

WinCC flexible Runtime

© Siemens AG 2013

HMI Software
SIMATIC WinCC flexible options
SIMATIC Logon for WinCC flexible

■ Ordering data

Order No.

SIMATIC Logon V1.5
Basic license;
for panels or WinCC flexible
Runtime stations, the corresponding
number of additional
SIMATIC Logon Remote Access
licenses is required.

6ES7658-7BX51-0YA0

SIMATIC Logon Upgrade to V1.5

6ES7658-7BX51-0YE0

SIMATIC Logon Remote Access
for WinCC flexible (3 clients)
Remote access
for 3 WinCC flexible 2008 clients;
single license for 3 remote access
clients;
type of delivery:
CD, license key disk, Certificate
of License, Terms and Conditions
The number of licensed clients is
determined based on the amount
of installed SIMATIC logon remote
access licenses.

6ES7658-7BA00-2YB0

SIMATIC Logon Remote Access
for WinCC flexible (10 clients)
Remote access
for 10 WinCC flexible 2008 clients;
single license for 10 remote access
clients;
type of delivery:
CD, license key disk, Certificate
of License, Terms and Conditions
The number of licensed clients is
determined based on the amount
of installed SIMATIC logon remote
access licenses.

6ES7658-7BB00-2YB0

■ More information
Note
Do you need a specific modification or addition to the products
described here? Then take a look under "Customer-specific
products". There, we provide information on the Open Platform
Program for creating your own functions or Controls for
WinCC flexible.

4

Siemens ST 80 / ST PC · 2013

4/77

© Siemens AG 2013

HMI Software
SIMATIC WinCC flexible options
WinCC flexible /Sm@rtAccess

■ Overview

4

■ Benefits

• Option for SIMATIC WinCC flexible Runtime plus
SIMATIC Panels for communication between various
SIMATIC HMI systems.
• Available for the following SIMATIC HMI systems:
- Mobile Panel 177 PN, Mobile Panel 277
- TP 177B PN/DP, OP 177B PN/DP
- TP 270, TP 277, OP 270, OP 277
- MP 177, MP 270B, MP 277, MP 370, MP 377
- WinCC flexible Runtime
• Communication between HMI systems is established on the
basis of Ethernet networks, or via the intranet/Internet:
- Read and write access to variables;
WinCC flexible Runtime or SIMATIC Panels make data
(variables) available to other SIMATIC HMI systems or Office
applications.
- A SIMATIC HMI system can be used to control or monitor
another system remotely;
entry level for client/server configurations for distributed
operator stations or for solutions with headend or control
room.
• Local operation, visualization and data processing is as
possible as plant-wide access to information or central
archiving of process data. Integrated information flows ensure
an overview of the status of all processes.
• Licensing:
The license "WinCC flexible /Sm@rtAccess for Panel" or
"WinCC flexible/Sm@rtAccess for WinCC flexible Runtime"
must be installed on both the server and client HMI device.
Server applications are the options Sm@rtServer, HTTP-Server
and SOAP-Server. Client applications are the screen object
Sm@rtClient display, and the utilization of the communication
driver SIMATIC HTTP protocol.
No license is required on the client system for access to a
Sm@rtServer using the application Sm@rtClient.EXE or the
Microsoft Internet Explorer. A license is also not required for
the engineering system for configuring the runtime option.
Note:
If the operator stations are accessed using the Sm@rtAccess
option, suitable protective measures (including IT security such
as network segmentation) should be taken in order to ensure
safe operation of the system.
You will find more information on the topic of Industrial Security
on the Internet at:
http://www.siemens.com/industrialsecurity

4/78

Siemens ST 80 / ST PC · 2013

• Flexible solution for location-independent access to
HMI systems and process data
• Reduction in load on fieldbuses:
WinCC flexible Runtime as well as SIMATIC Panels permit a
control system, for example, to access the process data. The
sensitive field level is not loaded by the control level as far as
the communications requirements are concerned. The
requirements are processed by WinCC flexible Runtime and
the SIMATIC Panels.
• Simple, fast configuration of communications relationships
using the WinCC flexible engineering software

■ Application
• Use of machine-level HMI systems as data servers for higherlevel automation components such as control systems or
office systems. Process values from different machines, for
example, are displayed on a process screen.
• Operator control and monitoring of machines covering large
areas with several operator stations by one operator
• Operator control and monitoring of machine-level HMI
systems from one central station (e.g. head-end station of a
production line or from a control room)

© Siemens AG 2013

HMI Software
SIMATIC WinCC flexible options
WinCC flexible /Sm@rtAccess

■ Application (continued)
Master Control Station
HTTP Data Client
SIMATIC HMI HTTP Protocol

Industrial Ethernet

Server 1

Server 2

HTTP-Data
Server/Client

HTTP-Data
Server/Client

Server 3

Server 4

HTTP-Data
Server/Client

HTTP-Data
Server/Client

G_ST80_XX_00070

PROFIBUS

Communication between HMI systems via Industrial Ethernet: Use of machine-level HMI systems as data servers for higher-level automation components

Sm@rtServer

Master Station

Sm@rtClient

Operator Station 1

Operator Station 2

Operator Station n

G_ST80_XX_00071

...

Industrial Ethernet

Application of the Sm@rtClient concept: Coordinated operation of several operator stations

Siemens ST 80 / ST PC · 2013

4/79

4

© Siemens AG 2013

HMI Software
SIMATIC WinCC flexible options
WinCC flexible /Sm@rtAccess

■ Application (continued)
Master Control Station

Sm@rtClient display

Industrial Ethernet

Server 1

Sm@rtServer

Server 2

Sm@rtServer

Server 3

Server 4

Sm@rtServer

Sm@rtServer

G_ST80_XX_00072

PROFIBUS

4
Use of the Sm@rtClient display: Operator control and monitoring of machine-level HMI systems from one central station

■ Function
Communication between different SIMATIC HMI systems or
between the units of a machine or plant is carried out via
Industrial Ethernet or intranet/Internet on the basis of
Sm@rtAccess
Possible communication relationships:
• Reading and writing the variables of a SIMATIC HMI system on
the basis of an HTTP protocol
- Reading and writing the variables of different HMI systems
- Simple configuring of variables in the HMI client configuration using browsers in the WinCC flexible engineering tool
- Reading and writing the variables of an HMI system using
standard applications such as MS Excel. Communication is
made possible by embedding a script in the application, on
the basis of the SOAP protocol (Simple Object Access
Protocol) superimposed by HTTP

4/80

Siemens ST 80 / ST PC · 2013

• Remote control of an operator station;
the HMI application and communication with the PLC are via
the master station. In the case of spatially distributed
machines/plants (which require a larger number of operator
panels), so-called Sm@rtClients can be activated from here
which are then assigned access to the master station and thus
to the process. Access procedures guarantee that only one
operator system can actively access the process at a time.
- A configurable graphic object (Sm@rtClient display)
embedded in process displays represents the screen of the
associated HMI system (Sm@rtServers)
- Powerful standard functions permit convenient and flexible
operation of the display
Password protection can be optionally activated for access to
variables or for remote operation of an HMI system.

© Siemens AG 2013

HMI Software
SIMATIC WinCC flexible options
WinCC flexible /Sm@rtAccess

■ Technical specifications
Type

■ Ordering data
WinCC flexible /Sm@rtAccess
The specifications are maximum
values

Execution platform
• SIMATIC Panels

• SIMATIC Multi Panels
• PCs

Mobile Panel 177 PN,
Mobile Panel 277,
TP/OP 177B PN/DP,
TP/OP 270, TP/OP 277
MP 177, MP 270B, MP 277,
MP 370, MP 377
WinCC flexible Runtime

Sm@rtAccess
SIMATIC HMI HTTP protocol
Number of connections for one client
• Mobile Panel 177 PN,
TP/OP 177 B PN/DP,
MP 177 as HTTP server
• Mobile Panel 277, TP/OP 270,
TP/OP 277, MP 270B, MP 277,
MP 370, MP 377 as HTTP server
• for WinCC flexible Runtime

4

8

16

Sm@rtAccess
Sm@rtClient concept
Number of Sm@rtClients that can
connect to a Sm@rtServer at the same
time1) 2)
• Mobile Panel 177 PN,
TP/OP 177B PN/DP,
MP 177 as Sm@rtServer
• Mobile Panel 277, TP/OP 270,
TP/OP 277, MP 270B, MP 277 as
Sm@rtServer
• MP 370, MP 377 as Sm@rtServer

• for WinCC flexible Runtime as
Sm@rtServer
Number of Sm@rtClient displays per
screen
• for Panels/Multi Panels
• for WinCC flexible Runtime

Order No.

WinCC flexible /Sm@rtAccess
for SIMATIC Panel 1)
Single license, license key only

6AV6618-7AB01-3AB0

WinCC flexible /Sm@rtAccess for
WinCC flexible 2008 Runtime 1)
Single license, license key only

6AV6618-7AD01-3AB0

1)

The license must be installed on the server and on the client HMI device.
Server applications are the options Sm@rtServer, HTTP-Server and
SOAP-Server.
Client applications are the screen object Sm@rtClient display, and the utilization of the communication driver HTTP protocol.
A license is not required for the engineering system for configuring the
runtime option.

■ More information
Note
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about the Open Platform Program for the
creation of user-specific functions and controls for
WinCC flexible.

4

2 clients

3 clients for 6" devices
2 clients for 8" and 10" devices
3 clients for 12" devices
2 clients for 15" devices
1 client for 19" devices
5 clients

1
2

1)

Including 1 Service Client

2)

The Sm@rtServer and the WinCC flexible /Pro Agent option cannot be used
simultaneously on OP/TP/MP 270/370. Parallel operation of the runtime
options ProAgent, Sm@rtAccess and Sm@rtService is possible in the
context of the MP 277 8" and 10" devices, Mobile Panel 277 as well as the
MP 377. Limitation: a maximum of 2 clients can be connected simultaneously to a Sm@rtServer.

Siemens ST 80 / ST PC · 2013

4/81

© Siemens AG 2013

HMI Software
SIMATIC WinCC flexible options
WinCC flexible /Sm@rtService

■ Overview

■ Function

• Option for SIMATIC WinCC flexible Runtime and
SIMATIC Panels for remote maintenance and servicing of
machines/plant via the Internet/intranet
• Available for the following SIMATIC HMI systems:
- Mobile Panel 177 PN, Mobile Panel 277
- TP 177B PN/DP, OP 177B PN/DP
- TP 270, TP 277, OP 270, OP 277
- MP 177, MP 270B, MP 277, MP 370, MP 377
- WinCC flexible Runtime
• Licensing
The "WinCC flexible /Sm@rtService for Panel" license or
"WinCC flexible /Sm@rtService for WinCC flexible Runtime"
license must be installed on the operator panels that use one
of the following options/functions: Sm@rtServer, HTML pages
(mini-Web server), e-mail.
The remote service PC and engineering system do not require
a license for configuration the runtime option.
Note
If the operator stations are accessed using the Sm@rtService
option, suitable protective measures (including IT security such
as network segmentation) should be taken in order to ensure
safe operation of the system.

4

You will find more information on the topic of Industrial Security
on the Internet at:
http://www.siemens.com/industrialsecurity

■ Benefits
• Fast elimination of faults or downtimes and thus increased
productivity by means of global access to machines/systems
by the service and maintenance personnel
• Avoids the need for site visits

■ Application
• Remote maintenance and servicing of machines and plants
via Internet/Intranet
• Calling of system information, control of target systems, and
updating of data sets via Internet/Intranet
• Automatic sending of emails to experts for fast elimination of
faults

4/82

Siemens ST 80 / ST PC · 2013

Remote operator control and monitoring of
SIMATIC HMI systems using Industrial Ethernet and/or
via the Intranet/Internet
Microsoft Internet Explorer V6.0 SP1 or higher is sufficient for
accessing an HMI system.
Remote control of an operating station
the HMI application and communication with the controller takes
place via the HMI system. Using Sm@rtService, the HMI systems
in the machines/systems can be serviced remotely. An access
process ensures that only one operator (either locally at the
machine or remotely via Internet Explorer) can actively access
the process at one time.
Integrated Web Server to process standard HTML pages
The following functions can be accessed from the homepage:
• Starting and stopping the HMI runtime for maintenance
• Remote access to recipe data sets, passwords and information specific to the HMI system
• Access the HMI system files via a file explorer
• Download configuration data via the Intranet/Internet
• Supplement with own HTML pages
Sending e-mails to maintenance personnel via SMTP server
(Simple Mail Transfer Protocol)
• Events that trigger an e-mail:
- Reporting of a message class
- Configurable standard functions: Changing the value of a
variable, pressing a function key, scripts, etc.
• Possible e-mail content
- Subject
- Message text with process variables
- Date/Time
• The optional use of e-mail/SMS gateways enables access to
standard networks (external service provider required)
Standard functions make maintenance and service functionality
easier. WinCC flexible allows you to quickly and easily configure
maintenance and service functions.
Password protection can be activated as an option for
accessing the HMI system. Different passwords may be
configured for different functions.

© Siemens AG 2013

HMI Software
SIMATIC WinCC flexible options
WinCC flexible /Sm@rtService

■ Function (continued)

Engineering Station
PC/PG

{jwVpw
l•Ž•ŒŒ™•ŽGz›ˆ›–•
wjVwn

jˆšŒGYaG
v—Œ™ˆ›–™GŠ–•›™–“Gˆ•‹G”–•›–™•Ž
œš•ŽG›ŒGp•›Œ™•Œ›Vp•›™ˆ•Œ›Gž›
ˆŠŠŒššG›–G›ŒGŠ–”—“Œ›ŒG‹ŒŠŒb
š–›’Œ šGˆ•‹Gœ•Š›–•G’Œ š

pzkuVkzs
t–‹Œ”Vy–œ›Œ™

jˆšŒGXaG
v—Œ™ˆ›–™GŠ–•›™–“Gˆ•‹G”–•›–™•Ž
œš•ŽG›ŒGtŠ™–š–›Gp•›Œ™•Œ›G
lŸ—“–™Œ™

p•›Œ™•Œ›
p•‹œš›™ˆ“Gl›Œ™•Œ›

G_ST80_XX_00073

p•‹œš›™ˆ“G

Remote operator control and monitoring of SIMATIC HMI systems using
Industrial Ethernet and/or via the Intranet/Internet

n†z{_W††WWW^]

pzkuVkzs
t–‹Œ”Vy–œ›Œ™

wyvmpi|z

Remote operator control and monitoring of SIMATIC HMI systems using
Industrial Ethernet and/or via the Intranet/Internet

zt{wGzŒ™Œ™
p•‹œš›™ˆ“G

p•›Œ™•Œ›

pzkuVkzs
t–‹Œ”V
y–œ›Œ™

l•Ž•ŒŒ™•ŽG
z›ˆ›–•GwjVwn
{jwVpw

{jwVpw
pzkuVkzs
t–‹Œ”Vy–œ›Œ™

žžžSGtlzS
vŠŒGˆ™Œˆ

p•‹œš›™ˆ“G
l›Œ™•Œ›

G_ST80_XX_00074

wyvmpi|z

p•›Œ™•Œ›
zŒ™ŠŒ
w™–‹Œ™

Remote operator control and monitoring of SIMATIC HMI systems using
Industrial Ethernet and/or via the Intranet/Internet

n†z{_W††WWW^\

pzkuVkzs
t–‹Œ”Vy–œ›Œ™

wyvmpi|z

Sending e-mails to maintenance personnel via SMTP server
(Simple Mail Transfer Protocol)

Siemens ST 80 / ST PC · 2013

4/83

4

© Siemens AG 2013

HMI Software
SIMATIC WinCC flexible options
WinCC flexible /Sm@rtService

■ Technical specifications
Type

■ Ordering data
WinCC flexible /Sm@rtService

Execution platform
• SIMATIC Panels

• SIMATIC Multi Panels
• PCs

Mobile Panel 177 PN,
Mobile Panel 277, TP 177B PN/DP,
OP 177B PN/DP, TP/OP 270,
TP/OP 277
MP 177, MP 270B, MP 277, MP 370,
MP 377
SIMATIC WinCC flexible Runtime

Sm@rtService 1)
Remote access via
HTML pages
• for Panels/Multi Panels

Internet Explorer V6.0 SP1 and
higher

• for WinCC flexible Runtime

HTML V1.1
(no support for ActiveX, Java, ASP)
HTML V1.1

Sending emails

• via SMTP server
• Subject, message texts with
250 characters of text per email;
date/time of message,
message No.

1)

4

The Sm@rtServer and the WinCC flexible /ProAgent option cannot be used
simultaneously on OP/TP/MP 270/370. Parallel operation of the runtime
options ProAgent, Sm@rtAccess and Sm@rtService is possible in the
context of the MP 277 8" and 10" devices, Mobile Panel 277 as well as the
MP 377. Limitation: a maximum of 2 clients can be connected with a
Sm@rtServer.

4/84

Siemens ST 80 / ST PC · 2013

Order No.

WinCC flexible /Sm@rtService
for SIMATIC Panels 1)
Single license, license key only

6AV6618-7BB01-3AB0

WinCC flexible /Sm@rtService for
WinCC flexible Runtime 2008 1)
Single license, license key only

6AV6618-7BD01-3AB0

1)

The "WinCC flexible /Sm@rtService for Panel" license or
"WinCC flexible /Sm@rtService for WinCC flexible Runtime" license must
be installed on the operator panels that use one of the following options:
Sm@rtServer, HTML pages, e-mail. The remote service PC and
engineering system do not require a license for configuration of the
Runtime option.

■ More information
Note
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about the Open Platform Program
for the creation of user-specific functions and controls for
WinCC flexible.

© Siemens AG 2013

HMI Software
SIMATIC WinCC flexible options
WinCC flexible /OPC server

■ Overview
Higher level visualization system

OPC Client

Industrial Ethernet
On-site visualization

OPC Server

OPC Server

OPC Server

Multi Panel

OPC Client
PROFIBUS
SIMATIC
S7-300

SIMATIC
S7-400

3rd party
OPC Server

• Option for SIMATIC WinCC flexible Runtime as well as Multi
Panels for communication with applications from different
vendors (e.g. MES, ERP, or applications in the office sector)

G_ST80_XX_00078

3rd party
PLCs

• Available for the following SIMATIC HMI systems:
- Mobile Panel 277, MP 270B, MP 277, MP 370, MP 377
(use of OPC on XML basis)
- WinCC flexible Runtime (use of OPC based on DCOM)
• One license is required for each operator station.

■ Benefits
• Incorporation of automation components from different
vendors into an automation concept
• Saving of development costs through communication
between automation systems based on a homogeneous,
uniform protocol

• Reduction in load on fieldbuses:
WinCC flexible Runtime as well as SIMATIC Panels permit
a control system, for example, to access the process data.
The sensitive field level is not loaded by the control level as far
as the communications requirements are concerned. The
requirements are processed by WinCC flexible Runtime and
the SIMATIC Panels.

■ Application
OPC (OLE for Process Control) is a standardized, open, uniform
and multi-vendor software interface. OPC is based on the
Windows technology of COM (Component Object Model),
DCOM (Distributed COM) or on XML.
Windows-based systems such as SIMATIC Panel PC or
SIMATIC Multi Panels are used for tasks at the machine and
process levels, and can communicate with all OPC-compatible
applications via Ethernet using TCP/IP and OPC. WinCC flexible
Runtime or the SIMATIC Multi Panel (OPC server) provide data
for one or more OPC clients. As a result, local visualization and
data processing are possible to the same extent as plant-wide
calling of information or archiving of process data. Uniform flows
of information guarantee an overview of the status of all
processes.

Communication with OPC-compatible applications from different
vendors (e.g. MES, ERP, or applications in the office sector) is
possible.
OPC Foundation
http://www.opcfoundation.org

Siemens ST 80 / ST PC · 2013

4/85

4

© Siemens AG 2013

HMI Software
SIMATIC WinCC flexible options
WinCC flexible /OPC server

■ Function

■ Ordering data

• Use of a visualization system as a data server (OPC server) for
higher-level automation components such as control systems
or office systems
- OPC-XML server for multi panels
- OPC server (DCOM) for WinCC flexible Runtime
• The WinCC flexible engineering system can conveniently
select a desired OPC item from the variables function of the
OPC server using an OPC browser (component of the OPC
server). To do this, the OPC server must be started and must
be accessible for the engineering system.

Execution platform
• SIMATIC Panels
• SIMATIC Multi Panels
• PCs
OPC server
• XML server for Multi Panels

4

• DCOM server for
WinCC flexible Runtime
• Number of connections that an
OPC server can accommodate
1)

WinCC flexible /OPC server
for WinCC flexible Runtime 2008 1)
Single license, license key only

6AV6618-7CD01-3AB0

1)

One license is required for each operator station.
A license is not required for the engineering system for configuring the
Runtime option.

WinCC flexible /OPC Server

Note

The specifications are maximum
values

Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about the Open Platform Program
for the creation of user-specific functions and controls for
WinCC flexible.

Mobile Panel 277
MP 270B, MP 277, MP 370, MP 377
SIMATIC WinCC flexible Runtime
Supports the OPC XML Data
Access specification V1.0 1)
Supports the OPC Data Access
specification V1.0a and V2.0
8

Data access via XML has a functional scope that is similar to OPC Data
Access. A software adapter is required that must be installed on the OPC
client PC to enable DCOM-based OPC clients to access the OPC XML
server without any modification. The software adapter is supplied with
WinCC flexible Engineering and Runtime.

4/86

6AV6618-7CC01-3AB0

■ More information

■ Technical specifications
Type

Order No.

WinCC flexible /OPC Server
for SIMATIC Multi Panels 1)
Single license, license key only

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

HMI Software
SIMATIC WinCC flexible options
WinCC flexible /ProAgent

■ Overview

■ Ordering data

Order No.

WinCC flexible /ProAgent
Software option package for
process diagnostics based on
Functional enhancement for
SIMATIC WinCC flexible; electronic
documentation in English, French,
German, Italian, and Spanish
• WinCC flexible /ProAgent
for SIMATIC Panels 1)
Runtime license (Single License)
executable on Mobile Panel 277,
TP/OP/MP 270/277 and
MP 370/377
• WinCC flexible/ProAgent for
WinCC flexible Runtime 2008 1)
Runtime license (single license)

67(3

G_ST80_XX_00367

1)

• Targeted and rapid process diagnostics in plants and
machines for SIMATIC S7 and SIMATIC HMI
• Standardized diagnostics concept for various SIMATIC
components
• No further configuration overhead for diagnostics functionality
• Frees up PLC capacity with regard to memory and program
execution time

6AV6618-7DB01-3AB0

6AV6618-7DD01-3AB0

One license is required for each operator station. A license is not required
for the engineering system for configuring the Runtime option.

■ More information
Note
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about the Open Platform Program
for the creation of user-specific functions and controls for
WinCC flexible.

Note
For further information, refer to
"SIMATIC ProAgent Process Diagnostics Software".

Siemens ST 80 / ST PC · 2013

4/87

4

© Siemens AG 2013

HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC

■ Overview
Current versions:
SIMATIC WinCC V7.2
Executable with:
• Windows 7 SP1 (32 / 64 bit) Professional, Enterprise, Ultimate
• Windows XP Professional SP3
• Windows Server 2003 SP2, Standard
• Windows Server 2008 SP2 (32 bit) Standard
• Windows Server 2008 R2 SP1 (64 bit) Standard
• contains the Microsoft SQL Server 2008 R2 SP1 (32 bit)
SIMATIC WinCC V7.0 SP3

4

• PC-based operator control and monitoring system for visualizing and operating processes, production flows, machines
and plants in all sectors – from the simple single-user station
through to distributed multi-user systems with redundant
servers and cross-location solutions with Web clients. WinCC
is the information hub for corporation-wide vertical integration.
• The basic system configuration (WinCC basic software)
includes industry-standard functions for signaling and
acknowledging events, archiving of messages and measured
values, logging of all process and configuration data, user
administration and visualization.
• The WinCC basic software forms the core of a wide range of
different applications. Based on the open programming interfaces, a wide range of WinCC options (from Siemens Industry
Automation) and WinCC add-ons have been developed
(by Siemens-internal and external partners).
• WinCC can be operated with every PC that meets the given
HW requirements. The SIMATIC Box / Panel PC and SIMATIC
Rack PC product range in particular is available for the industrial use of WinCC systems. SIMATIC PCs impress with their
powerful PC technology, are designed for round-the-clock
operation, and can be operated in both office areas and harsh
industrial environments.
• SIMATIC WinCC can be ordered in combination with a
SIMATIC IPC (Box/Rack/Panel PC) as SIMATIC HMI Package
at a price advantage
• Together with the SIMATIC IPC427C and IPC477C there are
turnkey solutions available as WinCC standard client or single
station (see also Packages and IPC427C/IPC477C)

4/88

Siemens ST 80 / ST PC · 2013

Executable with:
• Windows 7 SP1 (32 / 64 bit) Professional, Enterprise, Ultimate
• Windows XP Professional SP3
• Windows Server 2003 SP2 and
Windows Server 2003 R2 SP2 Standard
• Windows Server 2008 SP2 (32 bit) Standard
• Windows Server 2008 R2 SP1 (64 bit) Standard
includes the Microsoft SQL Server 2005 SP4
• Use in virtual environments – for additional information, see
http://support.automation.siemens.com/WW/view/en/
49370459
SIMATIC WinCC V6.2 SP3
Executable with:
• Windows XP Professional SP3
• Windows 2000 Professional SP4
• Windows Server 2003 SP2 and Windows Server 2003 R2 SP2
include Microsoft SQL Server 2005 SP2

© Siemens AG 2013

HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC

■ Benefits
• All-purpose
- Solutions for all sectors
- Multilingual for worldwide usage
- Can be integrated into all automation solutions
• All HMI functions on board
- User administration
- Operator control and monitoring
- Reporting, acknowledging, and archiving of events
- Acquisition, compression and archiving of measured values
(incl. long-term backup)
- Logging and documenting of process and configuration
data
• Can be configured simply and efficiently
- Configuration wizards let the user focus on the essentials
- In the picture by means of cross-reference lists and screen
property displays
- Configuration of multilingual applications
- Configuring tool for configuring bulk data
• Universally scalable
- Expandable from single station to client-server configurations
- Increased availability by means of redundant servers
- Process visualization via the web with the
WinCC WebNavigator
• Open standards for simple integration
- Powerful real-time database Microsoft SQL Server 2008 R2
SP1 (32 bit)
- Open for application modules with ActiveX controls
- Visual Basic for Applications for individual expansions
- OPC for cross-vendor communication
• Process visualization with Plant Intelligence
- Integrated high-performance Historian on the basis of the
Microsoft SQL Server 2008 R2 SP1 (32 bit)
- Integrated evaluation functions for the online analysis
(statistical process control)
- Production optimization with the help of diverse options
• Expandable using options and add-ons
- Options for scalable configurations
- Options for increasing the availability
- Options for IT & business integration
- Options for SCADA expansions
- Options for validation in accordance with
FDA 21 CFR Part 11
- Options for the use of telecontrol protocols
• Part of Totally Integrated Automation
- Direct access to the tag and message configuration of the
SIMATIC control system
- Integrated diagnostic functions for increasing productivity
- Options for the use of telecontrol protocols

New in V7.2
• Expansion into Graphic Designer
- Know-how protection by means of password protection for
PDL images and image blocks
• Unicode support
- WinCC SETUP in 5 languages / up to 9 installed languages
- Individual language selection for engineering and runtime,
regardless of the language settings in the operating system
• Simplified configuration of the Tag Management by means of
the innovative WinCC Configuration Studio
- Configuration options similar to those in Excel
- Simplified tags / structure tag management
• New communication channels
- Communication channel to new CPU (S7-1200 / S7-1500)
(absolute address only, no CPU alarming support)
- Introduction of the OPC UA server (DA, HDA)
• Expansion into archive system
- New archive recording (day, weak, year)
- New archiving methods (difference)
and more ...

4

Siemens ST 80 / ST PC · 2013

4/89

© Siemens AG 2013

HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC

■ Application
SIMATIC WinCC is designed for visualization and operation of
processes, manufacturing cycles, machines and plants. With its
powerful process interface, especially to the SIMATIC family,
and the secure data archiving, WinCC enables highly available
solutions for the process control.
The sector-neutral basic system enables universal usage in all
automation applications. Sector-specific solutions can, for
example, be implemented using WinCC options (e.g. FDA
options for the pharmaceutical industry) and sector-specific
add-ons (e.g. for the water industry).

■ Design
SIMATIC WinCC is available as a complete package and as a
runtime package with 128, 512, 2048, 8192, 65536, 102400,
153600, 262144 PowerTags 1).
PowerTags are data points that are connected to controllers or
other data sources over a WinCC channel. Up to 32 alarms can
be obtained from one data point. Moreover, internal tags without
coupling are available for additional system performance. In
addition WinCC also contains 512 archive tags. Individual
archive licenses can be obtained for greater quantity structures.
Licenses for a multi-user configuration

4

The system software with the required number of PowerTags and
additionally the option WinCC/Server must be installed on the
WinCC server.
In the basic configuration, an RT128 or RT client license is sufficient for the WinCC clients. In order to configure on clients, an
RC128 or RC client license is required. Remote configuration is
possible if WinCC clients without their own project (UniClient) on
the server project are configured.
1)

■ Function
The powerful configuration functions of SIMATIC WinCC
contribute to a reduced engineering and training overhead and
lead to a more flexible use of personnel and greater operational
reliability. Whoever is familiar with Microsoft Windows can also
operate the WinCC Explorer, the central switching point of
WinCC.
In combination with other SIMATIC components, the system is
also equipped with auxiliary functions such as process
diagnostics and maintenance. All SIMATIC engineering tools
work together in the configuration of the functions.
SIMATIC WinCC offers a complete basic functionality for
process visualization and operation. To this end WinCC has a
number of editors and interfaces that can be used to individually
configure this functionality according to the respective application. Expansions of a WinCC station for control tasks are also
possible with minimal engineering effort.
WinCC editors

Task or configurable
runtime functionality

WinCC Explorer

Central project management for the
quick access to all project data and
central settings

WinCC Graphics Designer

Graphics system for user-defined
visualization and operation via pixelgraphic objects

WinCC Alarm Logging

Signaling system for detecting and
archiving events with display and
control options according to
DIN 19235; freely selectable
message classes, message display
and logging

WinCC Tag Logging

Process archiving for the acquisition, compression and storage of
measured values, e.g., presentation
in trend and table format as well as
further processing

WinCC Report Designer

Reporting and logging system for
time and event-controlled documentation of messages, operator inputs
and current process data in the form
of user reports or project documentation in an arbitrary layout

WinCC User Administrator

Tool for user-friendly administration
of users and authorizations

WinCC Global Script

Processing functions with limitless
functionality by means of the use of
VBScript and ANSI-C

V6: 128, 256, 1024, 8192, 65536 PowerTags

4/90

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
Integration in automation solutions

■ Function (continued)

WinCC is an open process visualization system and provides the
option to connect the most diverse control systems.

Interfaces
Task or configurable
runtime functionality

Approved communication software
Only communication software with the listed product versions
(or higher) should be used. Corresponding SIMATIC NET
upgrades are available for upgrading older versions.

Communication channels

For communication with subordinate
controls (SIMATIC protocols,
PROFIBUS DP, PROFIBUS FMS,
DDE and OPC server included in
the scope of delivery)

Standard interfaces

For the open integration of other
Windows applications via WinCC,
WinCC-OLE-DB, ActiveX, OLE,
DDE, OPC, etc.)

For the number of controls connectable via Industrial Ethernet
CP 1613, the following applies to a message frame length of
512 bytes:

Programming ports

For the individual access to data
and functions of WinCC and for the
integration in user programs with
VBA, VB Script, C-API (ODK),
C-Script (ANSI-C)

Type of connection

Number of nodes

SIMATIC S5
Ethernet Layer 4 + TCP/IP

Up to 60

SIMATIC S7 Protocol Suite

Up to 64

SIMATIC 505
Ethernet Layer 4 + TCP/IP

Up to 60

■ Integration
Integration in company-wide solutions
(IT and business integration)
WinCC is strictly based on Microsoft technology, which provides
the greatest possible compatibility and integration ability.
ActiveX and .net 1) controls support technology-specific and
industry-specific expansions. Cross-manufacturer communication is also a simple exercise. The reason: WinCC can be used
as an OPC client and server, and in addition to access to current
process values, it also supports standards such as OPC HDA
(Historical Data Access), OPC Alarm & Events, and OPC XML
Data Access.
Just as important: Visual Basic for Applications (VBA) for userspecific expansions of the WinCC Graphics Designer and Visual
Basic Scripting (VBS) as an easy-to-learn, open runtime
language. If desired, professional application developers can
also use ANSI-C. And access to the API programming interfaces
is really simple with the Open Development Kit ODK.
WinCC integrates a powerful and scalable historian function
based on Microsoft SQL Server 2005 into the basic system.
As a result, users have every possibility: from high-performance
archiving of current process data, to long-term archiving with
high data compression, through to a central information hub in
the form of a company-wide process historian. With the help of
the Central Archive Server option, this can be set up within the
framework of a WinCC solution. Versatile clients and tools for
evaluation, the open interfaces, and special options (Connectivity Pack, Connectivity Station, IndustrialDataBridge) provide
the basis for effective IT and business integration.
If external networks are accessed, suitable protective measures
(incl. IT security measures, such as network segmentation)
should be taken in order to ensure safe operation of the system.

Number of connectable controls

Via PROFIBUS, a maximum of 8 controls can be connected with
CP 5611, and a maximum of 44 controls with CP 5613. With
approx. 10 or more controls, the usage of Industrial Ethernet is
recommended.
Mixed operation with different controls
With their multi-protocol stack, the CP 1613 and CP 5613
communication processors allow parallel operation of two
protocols, such as for the mixed operation of different controls,
via a bus cable. WinCC supports the operation of two similar
interface boards only in connection with the channels
SIMATIC S5 Ethernet Layer 4 (2 x CP 1613), SIMATIC S7
Protocol Suite (2 x CP 1613, 2 x CP 5613) as well as
PROFIBUS DP (4 x CP 5613; each CP 5613 max. 122 slaves).
In addition to communication over industrial Ethernet CP 1613 or
PROFIBUS CP 5613, one CP 5611 can be used in each case for
communication with SIMATIC S7 via MPI.
Client-server communication
Communication between the clients and the server is via TCP/IP
protocol. Setting up a separate PC LAN is recommended. For
small projects with a correspondingly low incidence of message
frames, SIMATIC NET Industrial Ethernet communication can be
used for both process communication (WinCC/Server ↔ PLC)
and PC-PC communication (WinCC/client ↔ WinCC/server).
Channel DLL PROFIBUS DP
In accordance with the PROFIBUS standard, DP/slaves are
always permanently assigned to a DP master; i.e. a second
WinCC station (DP/master) cannot access the same controls
(DP/slave). This means that redundant operation of two WinCC
stations is not possible using the PROFIBUS DP connection.

You can find more information on the topic of Industrial Security
on the Internet at:
http://www.siemens.com/industrialsecurity
1)

Only supported in WinCC V7.0 or higher

Siemens ST 80 / ST PC · 2013

4/91

4

© Siemens AG 2013

HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC

■ Integration (continued)
Connection to controls from other manufacturers:
OPC (OLE for Process Control) is recommended for the
connection of controls from other manufacturers.
Current notes and information about OPC servers from various
suppliers can be found at: http://www.opcfoundation.org
WinCC supports the standards:
• OPC Data Access 2.05a
• OPC Data Access 3.00
• OPC XML Data Access 1.00
(Connectivity Pack / Connectivity Station)
• OPC HDA 1.20 (Connectivity Pack / Connectivity Station)
• OPC A&E 1.10 (Connectivity Pack / Connectivity Station)
• OPC UA Client Data Access
• OPC UA Server Data Access, HDA
(Connectivity Pack / Connectivity Station)

4

Connection overview
Protocol

Description

SIMATIC S7
SIMATIC S7 Protocol Suite

Channel DLL for S7 functions
via MPI, PROFIBUS or
Ethernet Layer 4 + TCP/IP

SIMATIC S5
SIMATIC S5 Ethernet Layer 4

Channel DLL for S5 Layer 4
communication + TCP/IP

SIMATIC S5 Programmer Port AS511

Channel DLL and driver for serial
communication with S5 using AS511
protocol to programmers port

SIMATIC S5 Serial 3964R

Channel DLL and driver for serial
communication with S5 using RK512
protocol

SIMATIC S5 PROFIBUS-FDL

Channel DLL for S5-FDL

SIMATIC 505
SIMATIC 505 Serial

Channel DLL and driver for serial
communication with 505 using NITP/
TBP protocol to SIMATIC 535/545/
555/565/575

SIMATIC 505 Ethernet Layer 4

Channel DLL for 505 Layer 4
communication

SIMATIC 505 TCP/IP

Channel DLL for 505 TCP/IP
communication

SIMATIC S7-1200, S7-1500 (WinCC 7.2 or higher)
SIMATIC S7-1200,
S7-1500 Channel 1)

Channel DLL for S7-1200
and S7-1500 communication

Controllers from other manufacturers (from WinCC V7.0 SP3)
Allen Bradley
Ethernet IP

Channel DLL and drivers for communication with Allen Bradley controllers via Ethernet TCP/IP using
Ethernet IP protocol

Modbus TCP/IP

Channel DLL and drivers for communication with Modicon controllers
via Ethernet TCP/IP using Modbus
TCP/IP protocol

Mitsubishi MC TCP/IP

Channel DLL and drivers for communication with Mitsubishi controllers via Ethernet TCP/IP using
Mitsubishi MC TCP/IP protocol

Cross-manufacturer

4/92

Siemens ST 80 / ST PC · 2013

OPC client 1) 2) for
DA, XML DA

Channel DLL for OPC communication, WinCC can acquire data from
OPC server applications.

OPC server for
DA, XML DA, A&E, HDA

Server applications for OPC communication; WinCC provides process data to OPC clients

OPC UA server for DA, HDA

Server applications for OPC UA
communication

PROFIBUS FMS

Channel DLL for PROFIBUS FMS

PROFIBUS DP

Channel DLL for PROFIBUS DP

SIMOTION

Channel DLL for SIMOTION

1)

WinCC version V7.2 or higher supports communication
with S7-1200 / S7-1500 CPU.
Restrictions: No symbolic address, type safe structure support
(absolute address only) No CPU alarming support

2)

Application note:
Parallel usage of the OPC client channel allows, for example, connection
to an SNMP-OPC server for visualization of the data contained there.
The SNMP OPC server enables monitoring of any network components
(such as switches) that support the SNMP protocol. You can find more
information under SIMATIC NET Communications Systems/SNMP OPC
Server.

3)

WinCC V7.0 SP3 and later supports OPC UA (United Architecture) Client
for DA.

© Siemens AG 2013

HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC

■ Integration (continued)
Communications components for PG/PC for SIMATIC (for WinCC V7.2)
Industrial Ethernet

SIMATIC S5
Ethernet
Layer 4

SIMATIC S5
TCP/IP

•

•

SIMATIC S7
Protocol
Suite

SIMATIC 505
Ethernet
Layer 4

SIMATIC 505
TCP/IP 1)

Order No.

WinCC – channel DLL
SIMATIC S5 Ethernet Layer 4
Channel DLL for S5 Layer 4
communication + TCP/IP

Included in the basic
package
Included in the basic
package

•

SIMATIC S7 Protocol Suite
Channel DLL for S7 functions

Included in the basic
package

•

SIMATIC 505 Ethernet Layer 4
Channel DLL for 505 Layer 4
communication
SIMATIC 505 TCP/IP 1)
Channel DLL for 505
TCP/IP communication

•

Included in the basic
package

•

6GK1161-2AA00

Communication components for extension of the OS/OP
CP 1612
PCI card for connecting a PG/PC to
Industrial Ethernet (SOFTNET-S7 or
SOFTNET-S7 Lean communication
software must be ordered separately)

•

•

SOFTNET-S7
Communication software for
S7 functions (max. 64 connections)
• Version 8.1 2)3)
for Windows 7 (32/64-bit)
and Server 2008 R2 (64-bit)
• Edition 2008 SP2 (V7.1) 2)
for Windows XP/2003 Server/(32-bit)
2008 Server

•

•

SOFTNET-S7 Lean
Communication software for S7
functions (max. 8 connections)
• Version 8.2 SP1 2) 4)
for Windows 7 (32/64-bit)
and Server 2008 R2 (64-bit)
• Edition 2008 SP2 (V7.1) 2) 4)
for Windows XP/2003 Server / (32-bit)
2008 Server

•

6GK1704-1CW81-3AA0

6GK1704-1CW71-3AA0

•

6GK1704-1LW08-2AA0

6GK1704-1LW71-3AA0

CP 1613
PCI card for connecting a PG/PC
to Industrial Ethernet
(S7-1613 communication software
must be ordered separately)

•

•

•

•

•

6GK1161-3AA00

CP 1613 A2
PCI card (32-bit) for connecting
a PG/PC to Industrial Ethernet
(S7-1613 communication software
required)

•

•

•

•

•

6GK1161-3AA01

CP 1623
PCI Express X1 card (32-bit) for
connecting a PG/PC to Industrial
Ethernet (S7-1613 communication
software required)

•

•

•

•

•

6GK1162-3AA00

S7-1613
Communication software for
S7 functions and S5/505 Layer 4
communication with TCP/IP
• Version 8.2 SP1 2)3)
for Windows 7 (32/64-bit)
and Server 2008 R2 (64-bit)
• Edition 2008 SP2 (V7.1) 2)
for Windows XP/2003 Server /
(32-bit) 2008 Server

•

•

•

•

6GK1716-1CB08-2AA0

6GK1 716-1CB71-3AA0

• System interface possible
1)

Via any interface board with NDIS 3.0 interface;
no separate communication software required

2)

See ordering data for SIMATIC NET upgrade packages

3)

SIMATIC NET Version 8.2 SP1

4)

SOFTNET-S7 Lean included in scope of supply of WinCC V7.2

Siemens ST 80 / ST PC · 2013

4/93

4

© Siemens AG 2013

HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC

■ Integration (continued)
Communication components for PG/PC for SIMATIC (for WinCC V7.0)
PROFIBUS

SIMATIC S5
PROFIBUS FDL

SIMATIC S7
Protocol Suite

PROFIBUS DP

PROFIBUS FMS

Order No.

WinCC – channel DLL
SIMATIC S5 PROFIBUS FDL
Channel DLL for S5-FDL

Included in the basic
package

•

SIMATIC S7 Protocol Suite
Channel DLL for S7 functions

Included in the basic
package

•

Included in the basic
package

•

PROFIBUS DP
Channel DLL for PROFIBUS DP

•

PROFIBUS FMS
Channel DLL for PROFIBUS FMS

Included in the basic
package

Communication components for extension of the OS/OP

4

CP 5611 A2
PCI card (32-bit) for connecting a
PG/PC to PROFIBUS or MPI
(communication software included in
WinCC basic package)

•

6GK1561-1AA01

CP 5612 2)
PCI card (32-bit) for connecting a PG/PC
to PROFIBUS (communication software
included in WinCC basic package)

•

6GK1561-2AA00

CP 5621
PCI Express X1 card (32-bit) for
connecting a PG/PC to PROFIBUS or
MPI (communication software included
in WinCC basic package)

•

6GK1562-1AA00

CP 5622 2)
PCI Express X1 card (32-bit) for
connecting a PG/PC to PROFIBUS
(communication software included in
WinCC basic package)

•

6GK1562-2AA00

CP 5711 2)
USB adapter for connecting a PG/PC
to PROFIBUS or MPI (communication
software included in the WinCC basic
package)

•

6GK1571-1AA00

CP 5512
PCMCIA card (Cardbus 32-bit) for
connecting a PG/PC to PROFIBUS or
MPI (communication software included
in WinCC basic package)

•

6GK1551-2AA00

• System interface possible
1)

See ordering data for SIMATIC NET upgrade package

2)

SIMATIC NET Version 8.2 SP1

4/94

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC

■ Integration (continued)
Communication components for PG/PC for SIMATIC (for WinCC V7.0)
PROFIBUS

SIMATIC S5
PROFIBUS FDL

SIMATIC S7
Protocol Suite

PROFIBUS DP

PROFIBUS FMS

Order No.

Communication components for extension of the OS/OP (continued)
CP 5613 A2
PCI card (32-bit) for connecting a PC
to PROFIBUS (S7-5613, DP-5613 or
FMS-5613 communication software
required)

•

•

•

•

6GK1561-3AA01

CP 5614 A2
PCI card (32-bit) for connecting a PC
to PROFIBUS (communication software
must be ordered separately)

•

•

•

•

6GK1561-4AA01

CP 5623
PCI Express X1 card (32-bit) for
connecting a PG/PC to PROFIBUS or
MPI (S7-5613 communication software
or DP-5613 or FMS-5613 required)

•

•

•

•

6GK1562-3AA00

S7-5613 communication software for
S7 functions + FDL
• Version 8.1 1) 2)
for Windows 7 (32/64-bit) and
Server 2008 R2 (64-bit)
• Edition 2008 SP2 (V7.1) 1) 2)
for Windows XP/2003 Server /
(32-bit) 2008 Server

•

•

DP-5613
Communication software for
DP master + FDL
• Version 8.1 1) 2)
for Windows 7 (32/64-bit)
and Server 2008 R2 (64-bit)
• Edition 2008 SP2 (V7.1) 1) 2)
for Windows XP/2003 Server /
(32-bit) 2008 Server

•

FMS-5613
Communication software for
PROFIBUS-FMS + FDL
• Edition 2008 SP2 (V7.1) 1) 2)
for Windows XP/2003 Server /
(32-bit) 2008 Server

•

6GK1713-5CB81-3AA0

6GK1713-5CB71-3AA0

4

•

6GK1713-5DB81-3AA0

6GK1713-5DB71-3AA0

•

6GK1713-5FB71-3AA0

• System interface possible
1)

See ordering data for SIMATIC NET upgrade package

2)

SIMATIC NET Version 8.2 SP1

Siemens ST 80 / ST PC · 2013

4/95

© Siemens AG 2013

HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC

■ Integration (continued)
Communication examples
SIMATIC NET PROFIBUS (S7 functions)
Standard PC
with WinCC
e.g. RC 64 k or RT 64 k

- CP 5613 A2
- CP 5623
- S7-5613
(communication software)

PROFIBUS

- CP 443-5 Extended
(DP/M, S7, S/R)
- CP 443-5 Basis (FMS, S7, S/R)
- NCM S7 PROFIBUS manual
(SIMATIC NET CD or
Internet Download)

4

SIMATIC S7-300

- CP 342-5 (DP, S7, S/R)
- CP 343-5 (FMS, S7, S/R)
- NCM S7 PROFIBUS manual
(SIMATIC NET CD or
Internet Download)

G_ST80_XX_00010

SIMATIC S7-400

WinCC single-user system: PROFIBUS with S7 communication

SIMATIC NET Industrial Ethernet (S7 functions)
Standard PC
with WinCC
e.g. RC 64 k or RT 64 k

- CP 1613 A2
6GK1 161-3AA01
- CP 1623
6GK1 162-3AA00
- S7-1613
(communication software)
6GK1 716-1CB80-3AA0

Industrial Ethernet

- CP 443-1 (S7, S/R) ISO + TCP
6GK7 443-1EX20-0XE0
- CP 443-1 Advanced
(S7, S/R, HTTP)
6GK7 443-1GX20-0XE0
- NCM S7 PROFIBUS manual
(SIMATIC NET CD or
Internet Download)

WinCC single-user system: Industrial Ethernet with S7 communication

4/96

Siemens ST 80 / ST PC · 2013

SIMATIC S7-300

- CP 343-1 (S7, S/R) ISO + TCP
6GK7 343-1EX30-0XE0
- CP 343-1 Advanced
(S7, S/R, HTTP)
6GK7 343-1GX30-0XE0
- NCM S7 PROFIBUS manual
(SIMATIC NET CD or
Internet Download)

G_ST80_XX_00011

SIMATIC S7-400

© Siemens AG 2013

HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC

■ Integration (continued)
SIMATIC NET PROFIBUS-FMS
- CP 5613 A2
6GK1 561-3AA00
- CP 5623
6GK1 562-3AA00
- FMS-5613
(communication software)
6GK1 713-5FB80-3AA0

Standard PC
with WinCC
e.g. RC 64 k or RT 64 k
+ FMS channel DLL

PROFIBUS FMS

SIMATIC S7-400
SIMATIC S7-300
- CP 443-5 Basic
- CP 343-5
(FMS, S7, S/R)
(FMS, S7, S/R)
6GK7 343-5FA01-0XE0 6GK7 443-5FX02-0XE0

SIMATIC S5115/135/155U

- COM 5431 FMS/DP
6GK1 745-1AD00-0EA0

G_ST80_XX_00012

- CP 5431 FMS/DP
6GK1 543-1AA01

WinCC single-user system: PROFIBUS FMS

without
operator controls:
32 clients
+ 3 web clients
or
50 web clients
+ 1 client

Standard PC
with WinCC
e.g. RC 64 k or RT 64 k

+ TCP/IP
interface module

Client

up to 4 clients
with operator
controls
Client

TERMINAL BUS TCP/IP

Server

PROCESS BUS (Industrial Ethernet/PROFIBUS)

SIMATIC S7-300

This allows you to set up the following application examples
- WinCC single-user system: SIMATIC NET PROFIBUS with S7 functions
- WinCC single-user system: SIMATIC NET Industrial Ethernet with S7 functions
- WinCC single-user system: SIMATIC NET PROFIBUS-FMS

G_ST80_XX_00013

SIMATIC S7-400

WinCC multi-user system with operable server

Siemens ST 80 / ST PC · 2013

4/97

4

© Siemens AG 2013

HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC

■ Integration (continued)
Higher-level visualisation system

- OPC server functionality
(included in WinCC basic package)
- TCP-IP interface board required

OPC Client

Industrial Ethernet
- OPC Server
functionality
(OPC Server
option for
WinCC flexible
required)

On-site visualization

OPC Server

OPC Server

- OPC Server
functionality
(included in WinCC
basic package)
- TCP-IP Interface
board required

OPC Client
OPC Server

PROFIBUS
SIMATIC S7-300

SIMATIC S7-400
third-party
PLCs

4
OPC link

4/98

Siemens ST 80 / ST PC · 2013

- OPC Client
functionality
(included in WinCC
basic package)
- OPC Server
required for
interfacing with
third-party PLCs

G_ST80_XX_00015

- integrated
PROFIBUS
interface

© Siemens AG 2013

HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC

■ Technical specifications
Type

SIMATIC WinCC V7.2 and V7.0 SP3

SIMATIC WinCC V6.2 SP3

Operating system

• Windows 7 (32 bit / 64 bit) Ultimate,
Professional and Enterprise

• Windows XP Professional SP3,

• Windows XP Professional SP3

• Windows Server 2003 SP2,

• Windows 2003 Server SP2 and
Windows 2003 Server R2 SP2

• Windows Server 2003 R2 SP2

• Windows 2000 Professional SP4,

• Windows Server 2008 SP2 (32 bit) Standard
• Windows Server 2008 R2 SP1 (64 bit) Standard
PC hardware requirements
Processor type 1)
• Minimum

Single-user station/server:
Pentium 4, 2.5 GHz 2)

Single-user station/server:
Pentium III, 1 GHz

Central Archive Server (V7.0 SP3):
Pentium 4, 2.5 GHz

Central Archive Server:
Pentium 4, 2 GHz

Client:
Pentium 3, 1 GHz 2)

Client:
Pentium III, 600 MHz

WebClient/DataMonitor Client: Pentium III, 600 MHz 2)
Single-user station/server:
Pentium 4 or Dual Core, 3 GHz 2)

Single-user station/server: Pentium 4, 2 GHz

Central Archive Server (V7.0 SP3):
Pentium 4 or Dual Core, 3 GHz

Central Archive Server:
Pentium 4, 2.5 GHz

Client: Pentium 4, 2 GHz 2)

Client: Pentium III, 1 GHz

WebClient/DataMonitor Client: Pentium III, 1 GHz

WebClient/DataMonitor Client: Pentium III, 1 GHz

Single-user station/server: 4 GB 2)

Single-user station: 512 MB, server: 1 GB

Central Archive Server: 4 GB

Central Archive Server: 1 GB

Client: 1 GB 2)

Client: 512 MB

WebClient/DataMonitor Client: 512 MB 2)
Single-user station/server: 8 GB 2)

WebClient/DataMonitor Client: 256 MB
Single-user station: >= 1 GB,
server: >1 GB

Central Archive Server: ≥ 4 GB

Central Archive Server: ≥ 2 GB

Client: 2 GB 2)

Client: 512 MB

WebClient/DataMonitor Client: 1 GB 2)

WebClient/DataMonitor Client: 512 MB

Graphics card
• Minimum
• Recommended

16 MB, 800 x 600 2)
32 MB, 1280 x 1024 2)

16 MB, 800 x 600
32 MB, 1280 x 1024

Hard disk
• Minimum

Single-user station/server: 80 GB

Single-user station/server: 20 GB

Client: 20 GB

Client: 5 GB

Central Archive Server: 40 GB

Central Archive Server: 40 GB

WebClient/DataMonitor Client: 5 GB
Single-user station/server: 160 GB

WebClient/DataMonitor Client: 5 GB
Single-user station/server: 80 GB

Client: 40 GB

Client: 20 GB

Central Archive Server: 2 x 80 GB

Central Archive Server: 2 x 80 GB

WebClient/DataMonitor Client: 10 GB

WebClient/DataMonitor Client: 10 GB

Server: >1.5 GB

Server: 1.5 GB

Client: 1.5 GB
Server: >10 GB

Client: 1 GB
Server: >10 GB

Client: >1.5 GB

Client: >1.5 GB

for software installation

for software installation

• Recommended

RAM
• Minimum

• Recommended

• Recommended

• Hard disk
(available memory for installation)
- Minimum
- Recommended

CD-ROM/DVD-ROM/disk drive/
USB port
1)

An AMD system with comparable performance can also be used

2)

Hardware requirements when using Microsoft XP Professional

Siemens ST 80 / ST PC · 2013

4

4/99

© Siemens AG 2013

HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC

■ Technical specifications (continued)
Type

SIMATIC WinCC

Functionality/
quantity structure
Number of messages
• Message text (number of characters)
• Message archive
• Process values per message
• Constant load of messages, max.
• Message burst, max.
Archives
• Archive data points
• Archive types
• Data storage format
• Measured values per second, max.
User archive
• Archives and views
• Product consisting of data record
and column per user archive
• Fields per user archive

4

Graphics system
• Number of screens
• Number of objects per screen
• Number of controllable fields per
screen

4/100

150,000
10 x 256
> 500,000 messages 1)
10
Central Archive Server: 100/sec
Server/single-user station: 10/s
Server/single-user station:
2,000/10 s every 5 min
Max. 120,000 per server 2)
Short-term archive with and
without long-term archiving
Microsoft SQL Server 2005
Server/single-user station: 5,000/s
500 each
320,000
500
System-limited 1)
System-limited 1)
System-limited 1)

Siemens ST 80 / ST PC · 2013

Type

SIMATIC WinCC

PowerTags

256 K 3)

Trends
• Trend views per image
• Trends per trend view

25
80

User administration
• User groups
• Number of users
• Authorization groups

128
128
999

Configuration languages
Protocols
• Message sequence reports
(simultaneously)
• Message archive reports
(simultaneously)
• User reports
• Report lines per group
• Variables per report
Multi-user system
• Server
• Clients for server
with operator station
• Clients for server
without operator station

5 European (Eng., Fr., Ger., It., Sp.),
4 Asian (simpl.+trad. Chi/Kor/Jpn) 4)
1 per server/single-user station
3
System-limited 1)
66
300 5)
18
4
32 clients + 3 WebClients or
50 WebClients + 1 client

1)

Dependent on the available storage space

2)

Dependent on the number of licensed archive variables

3)

Dependent on number of licensed PowerTags

4)

Asian versions for Version 7 SP1 or higher

5)

The number of variables per report is dependent on process communication performance

© Siemens AG 2013

HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC

■ Ordering data

Order No.

SIMATIC WinCC system software
V7.2

For upgrading from:

Runtime packages on DVD
Language/script versions: De, En,
Fr, It, Es; with license for
• WinCC RT Client
• 128 PowerTags (RT 128)
• 512 PowerTags (RT 512)
• 2048 PowerTags (RT 2048)
• 8192 PowerTags (RT 8192)
• 65536 PowerTags (RT 65536)
• 102400 PowerTags (RT 102400)
• 153600 PowerTags (RT 153600)
• 262144 PowerTags (RT 262144)

6AV6381-2CA07-2AX0
6AV6381-2BC07-2AX0
6AV6381-2BD07-2AX0
6AV6381-2BE07-2AX0
6AV6381-2BH07-2AX0
6AV6381-2BF07-2AX0
6AV6381-2BJ07-2AX0
6AV6381-2BK07-2AX0
6AV6381-2BL07-2AX0

Including 512 archive tags each
Complete packages on DVD
Language versions: De, En, Fr, It,
Es; with license for
• WinCC RC Client
• 128 PowerTags (RC 128)
• 512 PowerTags (RC 512)
• 2048 PowerTags (RC 2048)
• 8192 PowerTags (RC 8192)
• 65536 PowerTags (RC 65536)
• 102400 PowerTags (RC 102400)
• 153600 PowerTags (RC 153600)
• 262144 PowerTags (RC 262144)

6AV6381-2CB07-2AX0
6AV6381-2BM07-2AX0
6AV6381-2BN07-2AX0
6AV6381-2BP07-2AX0
6AV6381-2BS07-2AX0
6AV6381-2BQ07-2AX0
6AV6381-2BT07-2AX0
6AV6381-2BU07-2AX0
6AV6381-2BV07-2AX0

SIMATIC WinCC system software
V7.2 ASIA
Runtime packages on DVD
Language/script versions: En, Chs,
Cht, Kor, Jpn; with license for
• WinCC RT Client
• 128 PowerTags (RT 128)
• 512 PowerTags (RT 512)
• 2048 PowerTags (RT 2048)
• 8192 PowerTags (RT 8192)
• 65536 PowerTags (RT 65536)
• 102400 PowerTags (RT 102400)
• 153600 PowerTags (RT 153600)
• 262144 PowerTags (RT 262144)

Order No.
SIMATIC WinCC V7.2 Powerpacks

6AV6381-2CA07-2AV0
6AV6381-2BC07-2AV0
6AV6381-2BD07-2AV0
6AV6381-2BE07-2AV0
6AV6381-2BH07-2AV0
6AV6381-2BF07-2AV0
6AV6381-2BJ07-2AV0
6AV6381-2BK07-2AV0
6AV6381-2BL07-2AV0

Including 512 archive tags each
Complete packages on DVD
Language versions: EN, CHS, CHT,
KOR, JPN; with license for
• WinCC RC Client
• 128 PowerTags (RC 128)
• 512 PowerTags (RC 512)
• 2048 PowerTags (RC 2048)
• 8192 PowerTags (RC 8192)
• 65536 PowerTags (RC 65536)
• 102400 PowerTags (RC 102400)
• 153600 PowerTags (RC 153600)
• 262144 PowerTags (RC 262144)

6AV6381-2CB07-2AV0
6AV6381-2BM07-2AV0
6AV6381-2BN07-2AV0
6AV6381-2BP07-2AV0
6AV6381-2BS07-2AV0
6AV6381-2BQ07-2AV0
6AV6381-2BT07-2AV0
6AV6381-2BU07-2AV0
6AV6381-2BV07-2AV0

Clients
• RT Client ASIA
• RT Client
• RC Client ASIA
• RC Client

6AV6381-2CA07-2AV0
6AV6381-2CA07-2AX0
6AV6381-2CB07-2AV0
6AV6381-2CB07-2AX0

Runtime packages
• 128 to 512 PowerTags
• 512 to 2048 PowerTags
• 2048 to 8192 PowerTags
• 8192 to 65536 PowerTags
• 65536 to 102400 PowerTags
• 102400 to 153600 PowerTags
• 153600 to 262144 PowerTags

6AV6371-2BD07-2AX0
6AV6371-2BG07-2AX0
6AV6371-2BM07-2AX0
6AV6371-2BN07-2AX0
6AV6371-2BP07-2AX0
6AV6371-2BQ07-2AX0
6AV6371-2BR07-2AX0

Complete packages
• 128 to 512 PowerTags
• 512 to 2048 PowerTags
• 2048 to 8192 PowerTags
• 8192 to 65536 PowerTags
• 65536 to 102400 PowerTags
• 102400 to 153600 PowerTags
• 153600 to 262144 PowerTags

6AV6371-2BD17-2AX0
6AV6371-2BG17-2AX0
6AV6371-2BM17-2AX0
6AV6371-2BN17-2AX0
6AV6371-2BP17-2AX0
6AV6371-2BQ17-2AX0
6AV6371-2BR17-2AX0

SIMATIC WinCC V7.2 archives
• 1500 archives
• 5000 archives
• 10000 archives
• 30000 archives
• 80000 archives

6AV6371-1DQ17-2AX0
6AV6371-1DQ17-2BX0
6AV6371-1DQ17-2CX0
6AV6371-1DQ17-2EX0
6AV6371-1DQ17-2GX0

4

SIMATIC WinCC V7.2
archive powerpacks
For upgrading archiving from
• 1500 to 5000 archive tags
• 5000 to 10000 archive tags
• 10000 to 30000 archive tags
• 30000 to 80000 archive tags

6AV6371-1DQ17-2AB0
6AV6371-1DQ17-2BC0
6AV6371-1DQ17-2CE0
6AV6371-1DQ17-2EG0

SIMATIC WinCC Upgrade/
Software Update Service
SIMATIC WinCC V7.2 upgrade 1)
For upgrading the RT version
• from V6.2 to V7.2
• from V7.0 to V7.2
• from V6.2 ASIA to V7.2 ASIA
• from V7.0 ASIA to V7.2 ASIA

6AV6381-2AA07-2AX4
6AV6381-2AA07-2AX3
6AV6381-2AA07-2AV4
6AV6381-2AA07-2AV3

For upgrading the Client RT version
• from V6.2 to V7.2
• from V7.0 to V7.2
• from V6.2 ASIA to V7.2 ASIA
• from V7.0 ASIA to V7.2 ASIA

6AV6381-2BC07-2AX4
6AV6381-2BC07-2AX3
6AV6381-2BC07-2AV4
6AV6381-2BC07-2AV3

For upgrading the RC version
• from V6.2 to V7.2
• from V7.0 to V7.2
• from V6.2 ASIA to V7.2 ASIA
• from V7.0 ASIA to V7.2 ASIA

6AV6381-2AB07-2AX4
6AV6381-2AB07-2AX3
6AV6381-2AB07-2AV4
6AV6381-2AB07-2AV3

SIMATIC WinCC Software Update
Service (SUS) 2) 3)
SIMATIC WinCC V7 Update
Software Update Service for
WinCC basic software and options:
• 1 license
• 3 licenses
• 10 licenses

6AV6381-1AA00-0AX5
6AV6381-1AA00-0BX5
6AV6381-1AA00-0CX5

1)

According to licensing provisions, 1 upgrade package must be ordered for
each WinCC station

2)

The Software Update Service is valid for 1 year. The contract is automatically extended by 1 more year unless canceled 3 months prior to
expiration. According to licensing provisions, 1 Software Update Service
must be ordered for each WinCC station.

3)

Requires the current software version

Siemens ST 80 / ST PC · 2013

4/101

© Siemens AG 2013

HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC

■ Ordering data

Order No.

For upgrading from:

Runtime packages on CD-ROM
Language/script versions:
DE/EN/FR/IT/ES; with license for
• 128 PowerTags (RT 128)
• 256 PowerTags (RT 256)
• 1024 PowerTags (RT 1024)
• 8192 PowerTags (RT 8192)
• 65536 PowerTags (RT 65536)
• 102400 PowerTags (RT 102400)
• 153600 PowerTags (RT 153600)
• 262144 PowerTags (RT 262144)

6AV6381-1BC06-2AX0
6AV6381-1BD06-2AX0
6AV6381-1BE06-2AX0
6AV6381-1BH06-2AX0
6AV6381-1BF06-2AX0
6AV6381-1BJ06-2AX0
6AV6381-1BK06-2AX0
6AV6381-1BL06-2AX0

Including 512 archive tags each
Complete packages on CD-ROM

4

Language versions:
DE/EN/FR/IT/ES; with license for
• 128 PowerTags (RC 128)
• 256 PowerTags (RC 256)
• 1024 PowerTags (RC 1024)
• 8192 PowerTags (RC 8192)
• 65536 PowerTags (RC 65536)
• 102400 PowerTags (RC 102400)
• 153600 PowerTags (RC 153600)
• 262144 PowerTags (RC 262144)

6AV6381-1BM06-2AX0
6AV6381-1BN06-2AX0
6AV6381-1BP06-2AX0
6AV6381-1BS06-2AX0
6AV6381-1BQ06-2AX0
6AV6381-1BT06-2AX0
6AV6381-1BU06-2AX0
6AV6381-1BV06-2AX0

Including 512 archive tags each
SIMATIC WinCC system software
V6.2 SP3 ASIA
Runtime packages on CD-ROM
Language versions: English/simplified and traditional Chinese/Korean/
Taiwanese/Japanese; with license
for
• 128 PowerTags (RT 128)
• 256 PowerTags (RT 256)
• 1024 PowerTags (RT 1024)
• 8192 PowerTags (RT 8192)
• 65536 PowerTags (RT 65536)

Order No.
SIMATIC WinCC V6.2 Powerpacks

SIMATIC WinCC system software
V6.2 SP3

Runtime packages
• 128 to 256 PowerTags
• 128 to 1024 PowerTags
• 128 to 8192 PowerTags
• 128 to 65536 PowerTags
• 256 to 1024 PowerTags
• 256 to 8192 PowerTags
• 256 to 65536 PowerTags
• 1024 to 8192 PowerTags
• 1024 to 65536 PowerTags
• 8192 to 65536 PowerTags

6AV6371-1BD06-2AX0
6AV6371-1BE06-2AX0
6AV6371-1BK06-2AX0
6AV6371-1BF06-2AX0
6AV6371-1BG06-2AX0
6AV6371-1BL06-2AX0
6AV6371-1BH06-2AX0
6AV6371-1BM06-2AX0
6AV6371-1BJ06-2AX0
6AV6371-1BN06-2AX0

Complete packages
• 128 to 256 PowerTags
• 128 to 1024 PowerTags
• 128 to 8192 PowerTags
• 128 to 65536 PowerTags
• 256 to 1024 PowerTags
• 256 to 8192 PowerTags
• 256 to 65536 PowerTags
• 1024 to 8192 PowerTags
• 1024 to 65536 PowerTags
• 8192 to 65536 PowerTags

6AV6371-1BD16-2AX0
6AV6371-1BE16-2AX0
6AV6371-1BK16-2AX0
6AV6371-1BF16-2AX0
6AV6371-1BG16-2AX0
6AV6371-1BL16-2AX0
6AV6371-1BH16-2AX0
6AV6371-1BM16-2AX0
6AV6371-1BJ16-2AX0
6AV6371-1BN16-2AX0

SIMATIC WinCC V6.2 Archive
• 1500 archives
• 5000 archives
• 10000 archives
• 30000 archives
• 80000 archives
• 120000 archives

6AV6371-1DQ16-2AX0
6AV6371-1DQ16-2BX0
6AV6371-1DQ16-2CX0
6AV6371-1DQ16-2EX0
6AV6371-1DQ16-2GX0
6AV6371-1DQ16-2JX0

SIMATIC WinCC V6.2
Archive Powerpacks
6AV6381-1BC06-2AV0
6AV6381-1BD06-2AV0
6AV6381-1BE06-2AV0
6AV6381-1BH06-2AV0
6AV6381-1BF06-2AV0

Including 512 archive tags each

For upgrading archiving from
• 1500 to 5000 archive tags
• 5000 to 10000 archive tags
• 10000 to 30000 archive tags
• 30000 to 80000 archive tags
• 80000 to 120000 archive tags

Complete packages on CD-ROM

SIMATIC WinCC V6.2 upgrade 1)

Language versions: English/simplified and traditional Chinese/Korean/
Taiwanese, Japanese; with license
for
• 128 PowerTags (RC 128)
• 256 PowerTags (RC 256)
• 1024 PowerTags (RC 1024)
• 8192 PowerTags (RC 8192)
• 65536 PowerTags (RC 65536)

6AV6381-1BM06-2AV0
6AV6381-1BN06-2AV0
6AV6381-1BP06-2AV0
6AV6381-1BS06-2AV0
6AV6381-1BQ06-2AV0

Including 512 archive tags each

For upgrading the RT version
• from V5.x to V6.2 SP3
• from V6.x to V6.2 SP3
• from V5.x ASIA to V6.2 SP3 ASIA
• from V6.x ASIA to V6.2 SP3 ASIA

6AV6381-1AA06-2AX4
6AV6381-1AA06-2AX3
6AV6381-1AA06-2AV4
6AV6381-1AA06-2AV3

For upgrading the RC version
• from V5.x to V6.2 SP3
• from V6.x to V6.2 SP3
• from V5.x ASIA to V6.2 SP3 ASIA
• from V6.x ASIA to V6.2 SP3 ASIA

6AV6381-1AB06-2AX4
6AV6381-1AB06-2AX3
6AV6381-1AB06-2AV4
6AV6381-1AB06-2AV3

1)

4/102

Siemens ST 80 / ST PC · 2013

6AV6371-1DQ16-2AB0
6AV6371-1DQ16-2BC0
6AV6371-1DQ16-2CE0
6AV6371-1DQ16-2EG0
6AV6371-1DQ16-2GJ0

According to licensing provisions, 1 upgrade package must be ordered for
each WinCC station.

© Siemens AG 2013

HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC

■ Ordering data

Order No.

SIMATIC WinCC V7.2
communication
Communication via
Industrial Ethernet
CP 1612 A2
PCI card (32-bit) for connection of a
programming device or PC to Industrial Ethernet (10/100/1000 Mbps)
with RJ45 connection via
SOFTNET S7 and SOFTNET PG
SOFTNET-IE S7 Version 8.2 SP1 1)
Software for S7-compatible and
S5-compatible communication incl.
OPC server, PG/OP communication
and NCM PC; up to 64 connections;
single license for one installation of
Runtime software, software and
electronic manual on CD-ROM;
license key on USB stick; Class A
for CP 1612-A2 English/German
• Single license for 1 installation
• Upgrade package for SIMATIC NET
Edition 2006 or higher
• Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2 and
Edition 2005
SOFTNET-IE S7 Lean
Version 8.2 SP1
(license included in scope of
delivery of WinCC V7.2)
Software for S7-compatible and
S5-compatible communication incl.
OPC server, PG/OP communication
and NCM PC; up to 8 connections;
single license for one installation of
Runtime software, software and
electronic manual on CD-ROM;
license key on USB stick; Class A
for CP 1612-A2 English/German
• Single license for 1 installation
• Upgrade package for SIMATIC NET
Edition 2006 or higher
• Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2 and
Edition 2005

6GK1161-2AA01

Order No.
HARDNET-IE S7 V8.2 SP1 1)
Software for S7-compatible and
S5-compatible communication
incl. OPC server,
PG/OP communication and
NCM PC,
single license for one installation of
Runtime software,
software and electronic manual on
CD-ROM,
license key on USB stick, Class A
for CP 1613-A2, CP 1623, CP 1628;
English/German
• Single license for 1 installation
• Upgrade package for SIMATIC NET
Edition 2006 or higher
• Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2 and
Edition 2005

6GK1716-1CB08-2AA0
6GK1716-1CB00-3AE0
6GK1716-1CB00-3AE1

Communication via PROFIBUS
6GK1704-1CW08-2AA0
6GK1704-1CW00-3AE0
6GK1704-1CW00-3AE1

6GK1704-1LW81-3AA0
6GK1704-1LW00-3AE0
6GK1704-1LW00-3AE1

CP 1613 A2
PCI card (32-bit) for connecting a
PG/PC to Industrial Ethernet (communications software must be
ordered separately)

6GK1161-3AA01

CP 1623
PCI Express X1 card (32-bit) for
connection of PG/PC to Industrial
Ethernet (communications software
must be ordered separately)

6GK1162-3AA00

CP 1628
PCI Express X1 card (32-bit) for
connection of PG/PC to Industrial
Ethernet (communications software
must be ordered separately)

6GK1162-8AA00

1)

According to licensing provisions, 1 upgrade package must be ordered for
each WinCC station

2)

The Software Update Service is valid for 1 year. The contract is automatically extended by 1 more year unless canceled 3 months prior to
expiration. According to licensing provisions, 1 Software Update Service
must be ordered for each WinCC station.

CP 5611 A2
PCI card (32-bit) for connecting a
PG/PC to PROFIBUS (communications software included in the
WinCC basic package)

6GK1561-1AA01

CP 5612 2)
PCI card (32-bit) for connecting a
PG/PC to PROFIBUS (communications software included in the
WinCC basic package)

6GK1561-2AA00

CP 5621
PCI Express X1 card (32-bit) for
connection of PG/PC to PROFIBUS
(communications software included
in WinCC basic package)

6GK1562-1AA00

CP 5622 2)
PCI Express X1 card (32-bit) for
connecting a PG/PC to PROFIBUS
(communications software included
in WinCC basic package)

6GK1562-2AA00

CP 5711
USB adapter for connecting a
PG/PC to PROFIBUS or MPI
(communications software included
in WinCC basic package)

6GK1571-1AA00

CP 5512
PCMCIA card (CARDBUS 32-bit) for
the connection of a PG/notebook to
PROFIBUS or MPI (communications
software included in WinCC basic
package)

6GK1551-2AA00

CP 5613 A2
PCI card (32-bit) for connecting a
PC to PROFIBUS (communications
software must be ordered separately)

6GK1561-3AA01

4

Siemens ST 80 / ST PC · 2013

4/103

© Siemens AG 2013

HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC

■ Ordering data

Order No.

Communication via PROFIBUS
(continued)
CP 5614 A2
PCI card (32-bit) for connecting a
PC to PROFIBUS (communications
software must be ordered separately)

6GK1561-4AA01

CP 5623
PCI Express X1 card (32-bit) for
connection of PG/PC to Industrial
Ethernet (communications software
must be ordered separately)

6GK1562-3AA00

CP 1612 A2
PCI card (32-bit) for connecting
a PG/PC to Industrial Ethernet
(SOFTNET-S7 must be ordered
separately)

HARDNET-PB S7 V8.2 SP1 1)
Software for S7 communication incl.
PG/OP communication, FDL, OPC
server, Runtime software, software
and electronic manual on CD-ROM,
license key on USB stick, Class A
for CP 5613-A2, CP 5614-A2,
CP 5623
English/German
• Single license for 1 installation
• Upgrade package for SIMATIC NET
Edition 2006 or higher
• Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2 and
Edition 2005

4

Order No.
SIMATIC WinCC V6.2
communication
Communication via
Industrial Ethernet

HARDNET-PB DP V8.2 SP1 1)
Software for DP protocol incl.
PG/OP communication, FDL, DP
OPC server,
Runtime software, software and
electronic manual on CD-ROM,
license key on USB stick, Class A,
for CP 5613-A2, CP 5614-A2,
CP 5623; English/German
• Single license for 1 installation
• Upgrade package for SIMATIC NET
Edition 2006 or higher
• Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2 and
Edition 2005

6GK1713-5CB08-2AA0
6GK1713-5CB00-3AE0
6GK1713-5CB00-3AE1

1)

6GK1713-5DB08-2AA0
6GK1713-5DB00-3AE0
6GK1713-5DB00-3AE1

(license included in scope of
delivery of WinCC V6.2)
Software for S7-compatible and
S5-compatible communication
incl. OPC server,
PG/OP communication and
NCM PC; up to 8 connections;
single license for one installation
of Runtime software,
software and electronic manual on
CD-ROM,
license key on USB stick, Class A,
for CP 1612-A2, English/German
• Single license for 1 installation
• Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2 and
Edition 2005 1)
CP 1613 A2
PCI card (32-bit) for connecting a
PG/PC to Industrial Ethernet (communications software must be
ordered separately)

6GK1713-5FB71-3AA0
6GK1713-5FB00-3AE0
6GK1713-5FB00-3AE1

According to licensing provisions, 1 upgrade package must be ordered for
each WinCC station

4/104

6GK1704-1CW71-3AA0
6GK1704-1CW00-3AE1

SOFTNET-S7 Lean V7.1 SP6
(Edition 2008+SP6) 1)

FMS-5613 V7.1 SP6
(Edition 2008+SP6) 1)
Software for FMS protocol incl.
PG/OP communication, FDL,
OPC server,
Runtime software, software and
electronic manual on CD-ROM,
license key on USB stick, Class A;
for CP 5613-A2, CP 5614-A2,
CP 5623; English/German
• Single license for 1 installation
• Upgrade package for SIMATIC NET
Edition 2006 or higher
• Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2 and
Edition 2005

SOFTNET-S7 V7.1 SP6
(Edition 2008+SP6) 1)
Software for S7-compatible and
S5-compatible communication
incl. OPC server,
PG/OP communication and
NCM PC; up to 64 connections;
single license for one installation
of Runtime software,
software and electronic manual on
CD-ROM,
license key on USB stick, Class A,
for CP 1612-A2, English/German
• Single license for 1 installation
• Upgrade package for
SIMATIC NET Edition 2007
Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2,
and Edition 2005 1)

6GK1161-2AA01

Siemens ST 80 / ST PC · 2013

S7-1613 V7.1 SP6
(Edition 2008+SP6) 1)
Software for S7-compatible and
S5-compatible communication
incl. PG/OP communication,
OPC server and NCM PC;
single license for one installation
of Runtime software,
software and electronic manual on
CD-ROM,
license key on USB stick, Class A
for CP 1613-A2; English/German
• Single license for 1 installation
• Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2 and
Edition 2005 1)

6GK1704-1LW71-3AA0
6GK1704-1LW00-3AE1

6GK1161-3AA01

6GK1716-1CB71-3AA0
6GK1716-1CB00-3AE1

© Siemens AG 2013

HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC

■ Ordering data

Order No.

Communication via
Industrial Ethernet
T7-1613 V7.1 SP6
(Edition 2008+SP6) 1)
Software for TF protocol, S5-compatible communication incl. OPC,
PG/OP communication (S5/505
layer 4 communication with TCP/IP)
single license for one installation of
Runtime software, software and
electronic manual on CD-ROM,
license key on USB stick; Class A
for CP 1613-A2 English/German
• Single license
• Upgrade package for
SIMATIC NET Edition 2007
Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2,
and Edition 2005 1)

6GK1716-1TB71-3AA0
6GK1716-1CB00-3AE1

Communication via PROFIBUS
CP 5611 A2
PCI card (32-bit) for connecting a
PG/PC to PROFIBUS (communications software included in the
WinCC basic package)

6GK1561-1AA01

CP 5621
PCI Express X1 card (32-bit) for
connection of PG/PC to PROFIBUS
(communications software included
in WinCC basic package)

6GK1562-1AA00

CP 5611 MPI
Comprising CP 5611 A2 and
MPI cable, 5 m

6GK1561-1AM01

CP 5621 MPI
Comprising CP 5621 (32-bit) and
MPI cable, 5 m

6GK1562-1AM00

CP 5512
PCMCIA card (CARDBUS 32-bit) for
the connection of a PG/notebook to
PROFIBUS or MPI (communications
software included in WinCC basic
package)

6GK1551-2AA00

CP 5613 A2
PCI card (32-bit) for connecting a
PC to PROFIBUS (communications
software must be ordered separately)

6GK1561-3AA01

CP 5614-A2
PCI Card (32-Bit) for connecting a
PC to PROFIBUS (communications
software must be ordered separately)

6GK1561-4AA01

1)

The SIMATIC NET PC software delivered with SIMATIC WinCC V7.2
must always be used. The scope of supply for WinCC V7.2 includes the
SIMATIC NET PC software V8.2 SP1 / supported operating systems:
32/64-bit Windows 7 Professional, Ultimate, 64-bit Windows Server 2008
R2 and SIMATIC NET PC Software V7.1 SP6 (Edition 2008+SP6) /
supported operating systems: 32-bit Windows XP Professional, Windows
Vista Professional, Ultimate, Windows Server 2003, Windows Server 2008
Standard.
Only the license is to be used from the scope of supply of the
above-listed SIMATIC NET PC software products. The licenses supplied
with SIMATIC NET V8.2 SP1 are valid for all older versions up to and
including Edition 2006.

Order No.
S7-5613 V7.1 SP6
(Edition 2008 SP6)
Software for S7 communication incl.
PG/OP communication, FDL, OPC
server; for Windows XP Professional/
2003 Server/2000 Professional/
Server for CP 5613/CP 5614;
English/German
• Single license for 1 installation
• Upgrade package
for SIMATIC NET Edition 2007
Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2,
and Edition 2005 1)
DP-5613 V7.1 SP6
(Edition 2008 + SP6)
Software for DP protocol incl. PG/OP
communication, FDL, OPC server,
Runtime software, software and
electronic manual on CD-ROM,
license key on USB flash drive,
Class A, for 32-bit: Windows XP
Professional, Windows 2003 Server,
Windows VISTA Ultimate/Business;
for CP 5613 A2; English/German
• Single license for 1 installation
• Upgrade package
for SIMATIC NET Edition 2007
Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2,
and Edition 2005 1)
FMS-5613 V7.1 SP6
(Edition 2008 + SP6)
Software for FMS protocol incl.
PG/OP communication, FDL,
FMS-OPC server, for Windows XP
Professional/2003 Server/2000
Professional/Server for
CP 5613/CP 5614; English/German
• Single license for 1 installation
• Upgrade package for
SIMATIC NET Edition 2007
Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2,
and Edition 2005 1)

6GK1713-5CB71-3AA0
6GK1713-5CB00-3AE1

6GK1713-5DB71-3AA0
6GK1713-5DB00-3AE1

4

6GK1713-5FB71-3AA0
6GK1713-5FB00-3AE1

Hardware for process control functions
DCF-77 receiver
for time synchronization
• DCF77 (Europe)

2XV9450-1AR14

Note
For further information on control technology options see
Catalog ST PCS7.

Siemens ST 80 / ST PC · 2013

4/105

© Siemens AG 2013

HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC

■ More information
WinCC language versions
SIMATIC WinCC is also offered in simplified Chinese, traditional
Chinese, Korean and Japanese especially for Asian markets.
These WinCC versions are intended for machine manufacturers,
plant constructors and exporters who supply the regions of
China, Taiwan, Korea and Japan.
WinCC ASIA includes all familiar WinCC functions and offers in
addition the configuration user interface in the respective
national language and English. The online help is available in
simplified Chinese, traditional Chinese, Korean, Japanese and
English. A Chinese, Korean, Japanese or multilingual Windows
operating system is required for operation.
WinCC ASIA is delivered on a separate DVD which contains all
of the above mentioned language versions. The corresponding
documentation can be obtained from the national subsidiaries in
China, Korea, Taiwan and Japan.
The runtime licenses are language-neutral. The English handling
program (Automation License Manager – ALM) is executable
under the Chinese, Korean and Japanese Windows versions.
In order to use the Asian languages in WinCC, an Asia hardware
dongle is required.

4

4/106

Siemens ST 80 / ST PC · 2013

Additional information is available on the Internet at:
http://www.siemens.com/wincc
Separate configurators are available for PC hardware:
• SIMATIC IPC547C, SIMATIC Rack PC 547B
• SIMATIC IPC647C, SIMATIC Rack PC 647B
• SIMATIC IPC847C, SIMATIC Rack PC 847B
• SIMATIC IPC427C
• SIMATIC IPC627C, SIMATIC Box PC 627B
• SIMATIC Box PC 827B
• SIMATIC HMI IPC577C, SIMATIC Panel PC 577B
• SIMATIC HMI IPC677C, SIMATIC Panel PC 677B

© Siemens AG 2013

HMI Software
SIMATIC WinCC options
SIMATIC WinCC options
Options for IT and Business Integration – Plant Intelligence
• SIMATIC InformationServer
Web-based, integrated reporting from production to
management, based on archived data
• WinCC/DataMonitor
For displaying and evaluating current process states and
historical data on office PCs with standard tools
• WinCC/DowntimeMonitor
For detecting and analyzing downtimes for machines and
plants
• WinCC/Connectivity Pack
Access to WinCC archives via OPC HDA, OPC A&E,
OPC XML Server and WinCC OLE-DB /OLE-DB
• WinCC/Connectivity Station
Gateway to WinCC server data over OPC HDA, OPC A&E,
OPC XML server and WinCC OLE-DB /OLE-DB from
independent computers
• WinCC/IndustrialDataBridge
Configurable connection to databases and IT systems

■ Overview

C
WinCis-SW
Bas C, RT
R

C
WinCtion
Op

C
WinCd-on
Ad

C
WinCtion
Op

C
WinCd-on
Ad

G_ST80_XX_00175

C
WinCtion
Op

C
WinCd-on
Ad

The universal WinCC basic software is the basis for modular
expansions. These functional expansions can be obtained in the
form of WinCC options and as WinCC Premium add-ons.
WinCC options are created by WinCC Development and are
Siemens Industry Automation products. You can obtain support
from our Advisory Services and via the central hotline.
Options for scalable plant configurations
• WinCC/Server
For configuring a powerful client/server system
• WinCC/Web Navigator
For controlling and monitoring plants via the Internet,
in-house intranet or LAN
• WinCC/TeleControl
For connecting to outlying stations (remote terminal units =
RTUs) via telecontrol protocols in a WinCC SCADA system.
• SIMATIC ProcessHistorian
Central scalable long-term archive for the whole plant
Options for increasing the availability
• WinCC/Redundancy
For increasing system availability through redundancy
• SIMATIC Maintenance Station
For system-integrated diagnostics and plant asset
management
• WinCC/ProAgent
For reliable process diagnostics

Options for SCADA expansions
• WinCC/User Archives
For managing data records in user archives
• WinCC/Calendar Scheduler
Calendar-based planning of events
• WinCC/Event Notifier
For sending of notifications depending on specific events in
the WinCC message system
Options for sector-specific expansions
• WinCC/ChangeControl
- Change and version management
- Generation of audit trails for engineering
• WinCC/Audit
- Change management
- Generation of audit trails for engineering and runtime
• SIMATIC Logon
- Central management of WinCC users, plant-wide
(to CFR 21 Part 11)
Options for individual system expansions
• WinCC/IndustrialX 1)
For creating customized WinCC ActiveX objects in a
VB development environment
• WinCC/ODK (Open Development Kit)
For the use of open programming interfaces
1)

For WinCC V7.2, the option WinCC/IndustrialX is part of the option
WinCC/ODK.

■ More information
WinCC options
http://www.siemens.com/wincc/options

Siemens ST 80 / ST PC · 2013

4/107

4

© Siemens AG 2013

HMI Software
SIMATIC WinCC options
SIMATIC BATCH for WinCC

■ Overview

■ Benefits

• WinCC in connection with the SIMATIC BATCH product range
offers a solution for the implementation of batch processes in
accordance with ISA S88.
• SIMATIC BATCH for WinCC is of particular interest where
different PLCs such as S7-400/300, S5 or non-Siemens PLCs
are to be used in a BATCH system.
• SIMATIC BATCH for WinCC is offered as a bundle that
includes the SIMATIC BATCH components as well as the
WinCC components.
• SIMATIC BATCH for WinCC contains the software for
SIMATIC BATCH including options, as well as for
SIMATIC WinCC including options. These products are
released for any combinations.
- SIMATIC BATCH for WinCC includes the licenses
SIMATIC BATCH Server (10 units 1)), SIMATIC BATCH CC,
and SIMATIC BATCH Recipe.
- All other SIMATIC BATCH and SIMATIC WinCC products
require the purchase of the relevant license or licenses.
1)

Current versions:
• SIMATIC BATCH for WinCC V7.1 SP1 (only runs on
Windows XP und Windows 2003 Server operating systems)
- WinCC V7.0 SP3
- SIMATIC BATCH V7.1 SP1
Configuration

S5-135U
S7-300/400

SIMATIC BATCH for WinCC

4/108

Siemens ST 80 / ST PC · 2013

SIMATIC BATCH for WinCC has been designed for:
• Batch processes in the WinCC environment in accordance
with ISA S88
• Users of S7-300, S7-400, S5 or non-Siemens controllers
• Users of STEP5/STEP7

SIMATIC BATCH for WinCC ships with the following 3 software
components and licenses:
• SIMATIC BATCH Server for 10 units
• SIMATIC BATCH Recipe system (Floating License)
• SIMATIC BATCH CC (Floating License)

PROCESS BUS

3rd-party PLCs

■ Application

■ Design

SIMATIC BATCH for WinCC
BASIC 10 Units

G_ST80_XX_00263

4

Units are the number of subsystems that can be operated with this license.

• SIMATIC BATCH for WinCC supports the user in the implementation of batch processes in accordance with ISA S88
• Modular architecture with flexible scalability and optimal
adaptation to plant size and individual requirements,
especially with regard to the use of PLCs such as
SIMATIC S7-400/300, SIMATIC S5 and non-Siemens devices
• High availability via redundant system configurations provides
protection against loss of batch data
• Cross-subsystem recipes with significant simplification of
recipe management
• Hierarchical recipes in accordance with ISA S88.01 for the
creation of recipes oriented toward process engineering
• Saving, archiving and comprehensive reporting of batch data
• Formula support
• Validation in accordance with 21 CFR Part 11 is significantly
simplified by functions such as Audit Trail (change log),
versioning of recipes, recipe operations and formulas,
electronic signature and access protection.

The following SIMATIC BATCH options can be used to expand
or configure a plant or the relevant licenses can be purchased:
• SIMATIC BATCH Recipe system (Floating License)
• SIMATIC BATCH Planning (Floating License)
• SIMATIC BATCH CC (Floating License)
• SIMATIC BATCH Library
• SIMATIC BATCH Hierarchical Recipe
• SIMATIC BATCH Formula
• SIMATIC BATCH Powerpacks (20, 40, 100, unlimited)

© Siemens AG 2013

HMI Software
SIMATIC WinCC options
SIMATIC BATCH for WinCC

■ Design (continued)

SIMATIC BATCH Separation, Procedures and Formulas offers
powerful functions for the following tasks:

The following basic products and SIMATIC WinCC options can
be used to expand or configure a plant or the relevant licenses
can be purchased.
• SIMATIC WinCC RT/RC (incl. Powerpacks)
• SIMATIC WinCC/Server
• SIMATIC WinCC/Redundancy
• SIMATIC WinCC/Archives (incl. Powerpacks)
• SIMATIC Logon
All previously listed software components including options of
SIMATIC BATCH and SIMATIC WinCC are supplied with the
product SIMATIC BATCH for WinCC. In addition, supplementary
components for configuring the interfaces between WinCC and
SIMATIC BATCH are included in the basic package.
The use and compatibility of WinCC and SIMATIC BATCH
is only guaranteed for the software versions that come with
SIMATIC BATCH for WinCC.

Formula 1

Formula 2

Formula 3

Quantity

1 000 kg

500 kg

900 kg

Temperature

90 °C
10 min

80 °C
15 min

95 °C
12 min

Yes
No
100 g

Yes
No
150 g

No
Yes
50 g

Time
Salt
Pepper
Sugar

Master Recipe #1

Master Recipe #2

Master Recipe #3

The functions of SIMATIC BATCH for WinCC are based on the
SIMATIC BATCH range of products. SIMATIC BATCH for WinCC
includes the following licenses or functions:
• SIMATIC BATCH Server for 10 units
• SIMATIC BATCH CC (BATCH Control Center)
• SIMATIC BATCH Recipe System (recipe editor)
It can be used to run a SIMATIC BATCH project with
10 subsystems on a single-user station or a client/server
combination (Batch Client and Batch Server).
The capacity of the Server Basic Packages with 10 units can be
expanded to 20, 40, 100 or unlimited units using SIMATIC
BATCH Powerpacks.
SIMATIC BATCH CC offers powerful functions for the following
tasks:
• Reading in and updating the plant data of the basic
automation
• Defining user privileges for all functions, for clients or
subsystems
• Definition of material names and codes
• Managing master recipes and starting the recipe editor
• Management of libraries with recipe elements
(library operations)
• Editing of formula categories and management of associated
formulas (parameter sets)
• Creation of batches with master recipes
• Starting of batch processing and controlling of batches
• Monitoring and diagnostics of batch processing
• Recording and archiving of recipes and batch data
Use of the "SIMATIC BATCH Hierarchical Recipe" license
permits the creation of hierarchical recipes in accordance with
ISA-88
The hierarchical recipe structure is mapped on the plant module
as follows:
• Recipe procedure for controlling the process or the
production in a plant
• Partial recipe procedure for controlling a process step in a
plant unit
• Recipe operation/function to implement the process
engineering task/function in a technical facility

G_PCS7_XX_00064

■ Function

The flexibility achieved by recipes which are independent of
plant units can be increased even further if the procedure and
parameter sets (formulas) are separated from one another.
Various master recipes can be created by linking several
formulas using a recipe procedure. This enables central modification of procedures. The formula structure is determined by the
formula category defined by the user.
Compatibility
In respect of compatibility, please note that only the SIMATIC
WinCC and SIMATIC BATCH versions included in the product
package are compatible with each other. Only predecessor
products of the product bundle SIMATIC BATCH for WinCC are
upward compatible, not single components of the product range
SIMATIC WinCC and SIMATIC BATCH.

■ Integration
A detailed description of how to integrate SIMATIC Batch in
WinCC appears in the interface description "SIMATIC BATCH
Configuration Guide".

■ Ordering data

Order No.

SIMATIC BATCH for WinCC
Software bundle for the creation
of recipes and control of batch processes in accordance with ISA S88
based on SIMATIC BATCH.
• SIMATIC BATCH Server 10 units
• SIMATIC BATCH Recipe system
(Floating License)
• SIMATIC BATCH CC
(Floating License)

6ES7657-1SA17-0YA0

Siemens ST 80 / ST PC · 2013

4/109

4

© Siemens AG 2013

HMI Software
SIMATIC WinCC options
SIMATIC Information Server

■ Overview
View in the Web browser

IS client

Add-ins for
Microsoft Word and Excel

4

The Information Server is the reporting system for WinCC and
the Process Historian. Based on Microsoft Reporting Services,
the historical data (tags and alarms) are made available via a
web client.
The Information Server Client does not need a client installation.
Using a pure web client, it offers functionality for administration,
configuration, and visualization of reports. Add-ins for Microsoft
Office applications such as Word and Excel offer additional
ways to access the WinCC and Process Historian database.
Reports can be created automatically cyclically and sent by
email. The Information Server can be used on a WinCC station,
on a Process Historian, or independently.
The basic package contains licenses for three clients and one
data source. The available licenses are additive and refer to
simultaneous access to the client computer. Pre-created report,
such as for trends and alarms, are contained in the standard
package.

■ Benefits
• Central, web-based report system as interface for all
corporate areas up to the management level.
• Simple handling through use of standard tools such as
Microsoft Word and Excel
• Provision of freely configurable reports via the web
• Automatic sending of reports via email
• Import of data from any number of WinCC applications
• Transparent access to WinCC tag and alarm logs as well as
SIMATIC Process Historian data

G_PCS7_XX_00298

Process Historian and
information server (IS)

Highlights:
• Frequently used report templates for process values,
messages, and batches
• Open reporting system for creating any number of new report
templates
• Storage of configured (parameterized) report templates for
faster access
• Report export in common document formats
• Support of subscriptions for cyclic report generation including
email service
• Creation and storage of role-based dashboards
• Role management for Windows users; supports workgroups
and Active Directory; user rights can be assigned for specific
projects
• Generation of reports and inserting as graphics in Microsoft
Office Word documents
• Creation of Microsoft Excel reports for historical process
values and messages as well as storage of the Excel report
templates on the Information
• Server Support for subscriptions to Excel report templates

■ Ordering data
SIMATIC Information Server 2013
"Basic Package"
• Information server
• Information Server Client access (3)
• Information Server Datasource access (1)
SIMATIC Information Server
• 1 Client access
• 3 Client access
• 5 Client access
• 10 Client access
• 1 Datasource access
• 3 Datasource access

4/110

Siemens ST 80 / ST PC · 2013

Order No.
6AV6361-2AA01-3AA0

6AV6361-2BD01-3BB0
6AV6361-2BE01-3BB0
6AV6361-2BF01-3BB0
6AV6361-2BG01-3BB0
6AV6361-2CD01-3BB0
6AV6361-2CE01-3BB0

© Siemens AG 2013

HMI Software
SIMATIC WinCC options
SIMATIC Logon

■ Overview

■ Function
SIMATIC Logon
Users receive a unique user ID, user name and password.
This information is stored encrypted at a central point
(for SIMATIC Logon in the Windows user management).
Functions such as changing the password, automatic logoff
after a predefined time and lockout after several incorrect entries
of a password ensure maximum security of operation.
In the case of the SIMATIC Logon, user administration is
integrated into the security system and user administration of
MS Windows.

• SIMATIC Logon (SL) for WinCC is a software option package
supporting the central administration of all WinCC users on a
plant-wide basis. The central user management with SL uses
the Windows mechanisms and is to be installed on all participating WinCC stations. The user management actions such as
logging in and out are automatically supplied in the audit trail
of WinCC/Audit and WinCC/ChangeControl by SL.
• The WinCC/Audit or WinCC/ChangeControl and
SIMATIC Logon options support users in respect of plant
validation and meet the requirements of FDA CFR 21 Part 11.
A declaration of conformity (White Paper) offers proof of this.

■ Benefits
• Central, system-wide user management
• Conforms with the requirements of the Food and Drug Administration (FDA) for the pharmaceuticals and food processing
industry

■ Design
The SIMATIC Logon Service can be used for the central user
management of a number of WinCC stations. Operation in a
Windows Workgroup or even in a domain is possible.

To meet in particular the Food and Drug Administration (FDA)
requirements for the pharmaceuticals and food processing
industry, all user and administrator actions, such as log in, log
out, password changes, incorrect password inputs, and creating
and deleting users, are recorded with timestamp in a secure
database or are available in the audit trail of WinCC/Change
Control or WinCC/Audit.
In addition, SIMATIC Logon allows setting up new users online,
plant-wide and across applications, or blocking existing users.
SIMATIC Logon also supports electronic signature.

■ Ordering data

Order No.

SIMATIC Logon V1.4 SP1

6ES7658-7BX41-2YA0

4

Central user management for
WinCC V6.2 and WinCC V7.0
Runtime license for an operator
station 1)
SIMATIC Logon V1.5 upgrade

6ES7658-7BX51-0YA0

Single License, 7 languages
(De, En, Fr, Es, Jap, Chin)
1)

SIMATIC Logon included in scope of supply of WinCC

■ More information
Information on FDA can be found in a White Paper:
Declaration of conformity of SIMATIC WinCC for FDA21 CFR
Part 11.
http://www.siemens.com/automation/hmi/html_76/products/
software/wincc/fda01.htm

Siemens ST 80 / ST PC · 2013

4/111

© Siemens AG 2013

HMI Software
SIMATIC WinCC options
SIMATIC Maintenance Station
• Scalability:
- Support of WinCC single-user stations and client/server
configurations.
- The SIMATIC Maintenance Station can be added to an
existing WinCC project.
• Consistency:
- The maintenance view is generated from the control project
and is consistent with it.
• Flexibility in selection of devices:
- Use of the PROFIBUS and PROFINET standards for device
interfacing.
- An additional proxy concept allows devices to be displayed
that are not included in the STEP 7 hardware configuration or
that do not support the standard diagnostics of PROFIBUS/
PROFINET.

■ Overview

■ Application

4

System-integrated plant asset management system
• Automatic generation of a maintenance view in WinCC from
the STEP 7 hardware configuration
• Plant-wide visualization of all automation components from the
management level to the field level in ready linked, hierarchically arranged WinCC displays
• Mapping of central and distributed SIMATIC S7 components,
PROFIBUS and PROFINET networks as well as associated
bus nodes
• Ethernet network components and industrial PCs can be
integrated through SIMATIC NET SNMP OPC Server
• Display of device status with group status generation in
overview and detail displays
• The device statuses "Maintenance required" and "Maintenance request" are supported for status-based maintenance
• Provision of uniform faceplates showing detailed information
for all components displayed
• Display of the device identification data
(electronic rating plate)
• Integrated display of the status of the request

■ Benefits
• Reducing down times:
- Problems in the plant are detected sooner due to the uniform
presentation and clear overview of all information that is
important for maintenance.
• Avoiding downtimes:
- Support of condition-based maintenance.
• Reduced maintenance costs:
- Optimization of the flow of information between production
and maintenance by submitting maintenance requests and
presenting the status of requests.
• Transparency and traceability:
- All procedures are based on messages and can therefore be
archived and traced.
- A comprehensive database is generated that can be
analyzed with WinCC functions or external tools.

4/112

Siemens ST 80 / ST PC · 2013

The SIMATIC Maintenance Station is a tool for the diagnosis and
maintenance of machines and plants. This is an option package
for STEP 7 V5.4 and WinCC V6.2 or V7.0 that generates a WinCC
maintenance view for a STEP 7 project/multiproject.

■ Design
The SIMATIC Maintenance Station is available in various
different packages:
• Basic package:
Contains all the tools needed to configure a Maintenance
Station and a license for the display of 100 devices.
• Powerpacks:
For larger quantities, powerpacks are available with licenses
for 100, 500 or 1000 devices. These can be added to the
existing licenses and can be combined as required.
In this context, devices can be:
• AS systems
• Distributed devices (PROFIBUS / PROFINET)
• PCs
• Network components
• Asset proxies
Requirements for configuring a
SIMATIC Maintenance Station
• STEP 7 license (V5.4 upwards)
• WinCC RC license (V7.0 upwards)
• The SIMATIC NET licenses required for the plant configuration
Requirements for operation of a
SIMATIC Maintenance Station
• The WinCC licenses (V7.0 upwards) complying with the plant
configuration

© Siemens AG 2013

HMI Software
SIMATIC WinCC options
SIMATIC Maintenance Station

■ Function

■ Technical specifications

Hierarchic visualization of plant components in WinCC
• Generation of a WinCC picture tree for hierarchic display of
the plant components.
• Automatic creation and linking of displays, equipment
symbols, status indicators, faceplates and the required
variables.
• Presentation of the detailed data in faceplates with selectable
views.
• Easy navigation in the plant using the WinCC Picture Tree
Manager.
• Generated pictures can be enhanced using the
WinCC Graphic Designer.
• Switchover between a WinCC SCADA project and the picture
tree of the SIMATIC Maintenance Station can be configured
using standard WinCC functions.

Hardware requirements

System

Operating system

Display of the current status of the plant and its components
• Clearly understandable status displays through the use of
uniform symbols.
• Display of no-fault status, fault, maintenance requirement and
maintenance request.
• Display of status of request for submitted repair requests.
• Display of order status.
• Display of the alarm status of the components.

Engineering station "ES"

Windows XP Professional SP3
Windows Server 2003 (R2) SP2
Windows Server 2008 R2 SP1
MS Windows 7 SP1.
Supported versions:
Ultimate and Professional

Maintenance Station Stand-alone /
WinCC-Station "Single-user Workstation"

Windows XP Professional SP3
Windows Server 2003 (R2) SP2
Windows Server 2008 R2 SP1
MS Windows 7 SP1.
Supported versions:
Ultimate and Professional

ES with Maintenance Station
Stand-alone

Windows XP Professional SP3
Windows Server 2003 (R2) SP2
Windows Server 2008 R2 SP1
Windows 7 SP1.
Supported versions:
Ultimate and Professional

Maintenance Station Server /
WinCC Server

Windows Server 2003 (R2) SP2
Windows Server 2008 SP2
Windows Server 2008 R2 SP1

Maintenance Station Client /
WinCC Client

Windows XP Professional SP3
Windows Server 2003 (R2) SP2
Windows Server 2008 SP2
Windows Server 2008 R2 SP1
Windows 7 SP1.
Supported versions:
Ultimate and Professional

Display of the identification data of the plant components
• Display of the identification data available for a device in the
faceplate for the device.
• Automatic loading of the data available in the configuration
into the maintenance station.
• Reading of the "Identification & Maintenance functions
(I&M1) )" in accordance with the PROFIBUS International
specification.
• Export2) of I&M data for all devices in the form of an XML file.
Displaying alarms
• Loading of system error messages from STEP 7.
STEP 7 provides the messages in 5 languages3),
translation into additional languages is possible in STEP 7.
• Display of the most recent message in a message line.
• Presentation of the active/archived messages of the selected
device in the faceplate.

System

Clock frequency

Main
memory

Free
hard disk
space

Engineering station

2.8 GHz

1 GB

15 GB

Maintenance Station Stand-alone /
WinCC-Station "Single-user
Workstation"

2.8 GHz

1 GB

15 GB

Maintenance Station Server /
WinCC Server

2.8 GHz

1 GB

15 GB

Maintenance Station Client /
WinCC Client

2.8 GHz

512 MB

3 GB

Software requirements

Calling the STEP 7 hardware configuration
• The STEP 7 hardware configuration can be opened for a
selected device using a button in the faceplate. STEP 7 and
the project must be installed on the maintenance station for
this purpose.
1)

The Maintenance Station 2007 supports reading of I&M data for
PROFIBUS devices with C1 channel access.

2)

The I&M data loaded from the configuration are exported.

3)

For Siemens components that are included in the STEP 7 hardware
catalog.
In the case of components that are integrated in STEP 7 using GSD files,
the GSD files must support the relevant languages.

Siemens ST 80 / ST PC · 2013

4/113

4

© Siemens AG 2013

HMI Software
SIMATIC WinCC options
SIMATIC Maintenance Station

■ Technical specifications (continued)

■ Ordering data

Requirements for the integration of devices
Type

Integration

SIMATIC S7 controllers / I/O
• S7-300 1)

Yes

• S7-400

Yes

• WinAC

Yes

Distributed devices
• ET 200

Yes

• PROFIBUS standard slaves

Yes

• PROFINET standard devices

Yes

Comment

PROFIBUS DP and
PROFINET IO
according to STEP 7
hardware catalog
Integration using a
GSD file
Integration using a
GSD file

Network components
Ethernet network components

Yes

PROFINET network components

Yes

PROFIBUS diagnostic repeater

Yes

SIMATIC NET SNMP
OPC Server and MIB
also required

Personal Computer

4

PC/Industrial PC

Yes

SIMATIC NET SNMP
OPC Server also
required

Drives with PROFIBUS connection

Yes

For integrating
devices designed
to the PROFIDRIVE
profile, Drive ES
SIMATIC (V5.4 SP1
or higher) is required

Drives with PROFINET connection

Yes

For integrating
devices designed
to the PROFIDRIVE
profile, Drive ES
SIMATIC (V5.4 SP1
or higher) is required

Yes

Integrated via
function block
(asset proxy)

Drives

Accessory devices
Devices not configured in STEP 7
Hardware Config
1)

With S7-300, PROFIBUS/PROFINET systems are supported if they are
connected to the internal CPU interfaces

4/114

Siemens ST 80 / ST PC · 2013

Order No.

SIMATIC Maintenance Station
2009
Can be used with STEP 7 V5.4 or
higher and WinCC V7
• Basic package
with engineering software
(Floating License) and Runtime
License for 100 devices
• Powerpack 100
Runtime License
for 100 additional devices
• Powerpack 500
Runtime License
for 500 additional devices
• Powerpack 1000
Runtime License
for 1000 additional devices
• Basic demo package 2009
• Upgrade from
SIMATIC Maintenance Station
2007 to SIMATIC Maintenance
Station 2009

6ES7840-0WD01-0YA0

6ES7840-0WD11-0YD0

6ES7840-0WD21-0YD0

6ES7840-0WD31-0YD0

6ES7840-0WD01-0YA7
6ES7840-0WD01-0YE0

© Siemens AG 2013

HMI Software
SIMATIC WinCC options
SIMATIC Process Historian

■ Overview

■ Function

Project A

Project B
OS clients

Information server

Terminal bus
OS single
station
- OS server
- Batch server

Process Historian

Automation
systems

G_PCS7_XX_00297

Plant bus

The Process Historian is a high-performance tong-term
archiving server solution that stores WinCC process values and
messages in a central database. The system offers full
scalability for performance and scope: It records and saves data
from one or several WinCC and PCS 7 projects. The number of
connected single stations, servers, or redundant server pairs is
unrestricted. SIMATIC Process Historian is designed for use
throughout your plant, below the corporate management level
(ERP, MES).
Process Historian is the basis for the Information Server
reporting system, which accesses the central Process Historian
database and ensures clear, user-friendly data visualization on
WinCC stations and office PCs.

• Real-time data storage of the WinCC archive data (process
values and messages) from any number of WinCC stations
• Visualization of the archive data on WinCC clients or WinCC
single stations either directly or using the SIMATIC Information
Server. Process Historian configuration tool for fast, simple
engineering
• The redundant Process Historian is based on Microsoft SQL
Server Mirroring (third system for monitoring the availability of
redundancy).
• The database and segmenting are set up in the initial
configuration.
• For archiving to the PH, the PH Ready component is installed
on the WinCC server
• The PH automatically detects all connected WinCC server
projects (via the PH Ready component)
• The "Process Historian Management" dashboard for
diagnostics, displaying data sources, changing the database
segmentation

■ Ordering data

Order No.

SIMATIC Process Historian Server
2013 Single License

6AV6361-1AA01-3AA0

SIMATIC Process Historian Server
2013 Single License
(Redundancy Complete)
• 2x Process Historian Server
• 2x Process Historian Server Redundancy

6AV6361-1BA01-3AA0

SIMATIC Process Historian 2013
Single License Redundancy

6AV6361-1CA01-3AA0

4

Upgrades
Upgrade from CAS
(Central Archive Server)
V7.0 SP3 to
Process Historian 2013

6AV6361-1AA01-3AE0

The central Process Historian database provides access to realtime data throughout the plant. This data is the key to sustainable
plant optimization.
Because this is a completely integratable archive system,
the engineering can also be performed without additional effort.
SIMATIC Process Historian uses the integrated relational
database Microsoft® SQL Server.
No complex reconfiguration is needed because the archive
system is integrated in WinCC. Time or event-driven archiving of
selected process values or messages in the WinCC long-term
archive is possible.

■ Benefits
• Fully integrated long-term archive solution for large volumes
of data
• Central, plant-wide long-term archive as company-wide
information hub
• Process data and messages can be archived from any
number of lower-level WinCC systems
• Plant expansions without interrupting the production process
• High availability in redundant mode
• High degree of security due to integrated backup system
• Database for analyses with the goal of optimizing the plant
and thus the productivity

Siemens ST 80 / ST PC · 2013

4/115

© Siemens AG 2013

HMI Software
SIMATIC WinCC options
WinCC/Calendar Scheduler

■ Overview

■ Benefits
• Simple operation, configuration and planning of events thanks
to handling in the style of Microsoft Office Calendar
• Simple configuration of the actions by parameterization
(execution of WinCC scripts or writing of WinCC tags at certain
times)
• Configuration of recurring events taking account of configurable public holidays, vacation periods, and maintenance
periods
• Secure operation of the plant taking account of different
authentication levels
• Clear representation of events at runtime by means of
Calendar Runtime Control
• Flexible use in all typical WinCC plant configurations,
client/server, redundant systems, WebNavigator

■ Function
With the WinCC Calendar Scheduler, events and their
associated actions can be configured in a user-friendly and
clear way in an editor in WinCC Explorer.

4

• Option for SIMATIC WinCC for managing events in a calendar.
• Setting WinCC variables or starting global scripts at defined
times.
• A license is only necessary on the server
(or single user system).

The events are represented in a calendar. The period represented can be freely selected. Recurring events can be defined
as serial events with any desired exceptions.
The events are displayed in a .Net control. The Calendar
Scheduler is easy and intuitive to operate and supports drag &
drop during configuration and runtime.

■ Ordering data

Order No.

WinCC/Calendar Scheduler
• for WinCC V7.2
• for WinCC V7.0 SP3

4/116

Siemens ST 80 / ST PC · 2013

6AV6372-1DC07-2AX0
6AV6372-1DC07-0AX0

© Siemens AG 2013

HMI Software
SIMATIC WinCC options
WinCC/Central Archive Server (CAS)

■ Overview
Central data management, reliable, high-performance archiving
and central backup mechanisms form the basis of a Process
Historian solution: Integration in the SCADA world, data interfaces for access to archived data and analysis functions are the
component parts.
The option CAS was designed for this purpose and is used to
export the archived data of all servers in the system to a
computer and manage it. Integration of CAS in the WinCC world
means that the data remains available for the WinCC clients as
well as for the WinCC standard interfaces.
WinCC/CAS contains all licenses for the central archive server
including 1500 archive tags. The number of archive tags can be
increased to 120000 using Powerpacks or further WinCC
archives.

■ Benefits
• Central data management of all archived alarms and process
values
• Integrated back-up system for the archive data
• Transparent access to the data from all WinCC clients and
over the open interfaces
• Integrated Web viewer for analyzing data

■ Function
Both the process value archive and alarm log are created on the
separate WinCC servers and transferred to CAS when individual
database segments have been closed.
With "Store&Forward", when the network is interrupted between
the WinCC server and CAS, data will be reliably transferred as
soon as the network is operating again.
Data access is transparent for display and analysis and is still
possible through the standard WinCC clients. For the clients, it
is of no consequence whether the data are on the WinCC server
or already on CAS. Data saved in CAS can also be viewed using
the Web viewer included in the package.
The data of the distributed WinCC system can also be accessed
through the familiar interfaces (OPC DA, OPC A&E, OPC HDA
and Ole-DB) with the help of the Connectivity Pack or the
Connectivity Station. In this manner, the data saved in CAS can
be efficiently transferred to higher-level systems or used for the
purposes of analysis.

■ Ordering data

Order No.

WinCC/CAS V7.0 SP3
basic packages
• WinCC/CAS V7.0 SP3
• WinCC/CAS V7.0 SP3 ASIA

6AV6371-1DQ17-0XX0
6AV6371-1DQ17-0XV0

WinCC/CAS upgrade
• V6.2 to V7.0 SP3
• V6.2 ASIA to V7.0 SP3 ASIA

6AV6371-1DQ17-0XX3
6AV6371-1DQ17-0XV3

WinCC/CAS V6.2 SP3
basic packages
• WinCC/CAS V6.2 SP3
• WinCC/CAS V6.2 SP3 ASIA

6AV6371-1DQ16-2XX0
6AV6371-1DQ16-2XV0

4

Note:
Standard Archive Powerpacks (see WinCC ordering data) can
also be used for WinCC/Central Archive Server (CAS)
WinCC V7.2 is not supported. The successor product is the
option Process Historian for V7.2.

Siemens ST 80 / ST PC · 2013

4/117

© Siemens AG 2013

HMI Software
SIMATIC WinCC options
WinCC/ChangeControl & WinCC/Audit

■ Overview

4

■ Benefits

• WinCC/ChangeControl is used to trace engineering
changes in a tamper-proof long-term audit trail database,
called the audit trail for short. All changes are automatically
entered in the engineering system in the audit trail. This
enables all the changes to be traced that have been made, to
deduce the causes and minimize downtimes on the system.
To begin tracing at a defined project status, a project version
definition is provided that contains all data and files of a
WinCC project version. The project version definition naturally
provides the ability to reactivate earlier project versions.
Document management is also provided, which manages and
archives intermediate status for system graphics, reports or
user files and stores change information of the user. An audit
viewer with helpful filter functions can be used for quickly and
simply evaluating the audit trail, exporting it to an Excel sheet
or printing it out.
• WinCC/Audit Includes the full functionality of
WinCC/ChangeControl and is also used for tracing all
operations. All operations are automatically recorded in the
audit trail at RT.
• Licensing : To configure which change information
from the project should be recorded in the audit trail, the
WinCC/ChangeControl RC or WinCC/Audit RC package is
required. "RC" stands for Runtime and Configuration. It is
required on the station that is to be configured and also
includes an RT license. For recording an audit trail, one
WinCC/Audit RT license is required per WinCC station
(Client/Server).
• The WinCC/Audit or WinCC/ChangeControl and
SIMATIC Logon options support users in respect of plant
validation and meet the requirements of FDA CFR 21 Part 11.
A declaration of conformity (White Paper) offers proof of this.

4/118

Siemens ST 80 / ST PC · 2013

• Quick and easy traceability configuration
• Gap-free and automated recording of engineering changes
and operator actions in an audit trail
• Reduction in plant downtimes thanks to fast analysis of the
gap-free recorded audit trail information
• Logging of defined WinCC project status with all database
information and files of the application
• Gap-free documentation of the project version definition
procedures with version number, user and comments
• Complete tracing support by WinCC single and multi-station
systems, single and multi-project solutions, Client/Server
architecture
• Extensive reduction in engineering outlay in order to meet the
requirements of FDA 21 CFR Part11 & EU 178/2002
• Compliance with the requirements of the Food and Drug
Administration (FDA) for the pharmaceutical and food
industries.

■ Design
WinCC/ChangeControl and WinCC/Audit consist of five components:
• The audit editor for configuration the audit trail content
• The project version definition for logging WinCC projects
• Document management for automatic archiving and
versioning of WinCC plant mimics, scripts, reports, and
project-specific documents, and the recording of the
associated change information
• The audit viewer for visualizing, exporting and printing
WinCC and WinCC flexible audit trails. The viewer is available
as an executable program under Windows, as well as OCX
with WinCC Runtime.
• The audit trail, which tracks all changes in respect of both
engineering and plant operation in a separate SQL database.
The audit trail can be set up as a central audit trail for a
number of projects or even just for a single project.
WinCC/ChangeControl and WinCC/Audit support both singleuser and multi-user systems, client/server architectures and
even the WinCC redundancy system. No redundant audit trail is
created however.

© Siemens AG 2013

HMI Software
SIMATIC WinCC options
WinCC/ChangeControl & WinCC/Audit

■ Function
WinCC/ChangeControl
WinCC/ChangeControl is a functional subset of WinCC/Audit.
WinCC/ChangeControl is for tracing engineering changes in the
engineering phase or in online operation. All change data is
recorded in an audit trail.
There are two types of engineering changes:
• those that change the WinCC database or are executed
through the WinCC Explorer, such as e.g. changes to tag
management or creating a user group,
and those
• limited to changing files, the so-called document administration.
The document management manages system images, scripts
and log layouts and customer-specific documents and stores
respective intermediate versions as backups. All of these
documents or files are subject to a change process, i.e.
documents can be booked out for processing, booked in for
finalization and intermediate versions can be retrieved from
backup storage with a rollback function.
The project version definition as a component of
WinCC/ChangeControl archives WinCC projects and creates
reproducible project status or defined start-time points for
starting tracing. An audit trail is also provided with information on
who has created which project version or which version has
been reproduced or deleted.
Configuring the audit trail, the project version definition and the
document management is simple, quick and comfortable.
The audit trail data is visualized from WinCC, as well as from
WinCC flexible via the audit viewer, an executable program
under Windows. The data can also be evaluated with the audit
viewer OCX in Runtime by WinCC however. Users select the
desired view of the audit trail information via filters or selection
criteria and can export the data to an Excel file or print it on a
printer. Audit trail information is tamper-proof and can thus not
be modified or deleted. An export function can be used to swap
out the audit trail to an XML file or to archive it.

■ Ordering data

Order No.

WinCC/ChangeControl
For the configuration
of the audit trail incl. RT
• WinCC V7.0 SP3
• V6.2, for WinCC V6.2 and
WinCC V6.2 SP2/SP3

6AV6371-1DV27-0AX0
6AV6371-1DV26-2AX0

WinCC/Audit RC
For the configuration of the audit
trail incl. RT
• WinCC V7.0 SP3
• V6.2, for WinCC V6.2 and
WinCC V6.2 SP2/SP3

6AV6371-1DV17-0AX0
6AV6371-1DV16-2AX0

WinCC/Audit RT
Creation of audit trails in RT
• WinCC V7.0 SP3
• V6.2, for WinCC V6.2 and
WinCC V6.2 SP2/SP3

6AV6371-1DV07-0AX0
6AV6371-1DV06-2AX0

Upgrades
V6.x to V7.0
• for WinCC/Audit RT
• for WinCC/Audit RC or
WinCC/ChangeControl

6AV6371-1DV07-0BX4
6AV6371-1DV17-0BX4

V6.x to V6.2
• for WinCC/Audit RC and
WinCC/Audit RT

6AV6371-1DV06-2AX3

4

■ More information
Information about FDA can be found in a White Paper:
Declaration of conformity of SIMATIC WinCC to FDA21 CFR
Part 11.
http://www.siemens.com/automation/hmi/html_76/products/
software/wincc/fda01.htm

WinCC/Audit
WinCC/Audit has all of the functionality of WinCC/ChangeControl
and is also used for tracing user operations in RT operation.
Tracing can be used for determining who, when and what conditions the machine has undergone. In addition to recording
operator activities, the audit trail also records the starting and
modifying of recipes or user logs. At specific objects or events,
such as function buttons or sliders, the user can also record
activities of an individual nature such as e.g., pressing a function
button, moving sliders and other actions with a so-called audit
entry function in the audit trail.
A WinCC/ChangeControl RC license or a WinCC/Audit RC
license is required for configuring the audit trail. One RT license
is required for each station (client/server) to be monitored. One
RC license always includes one RT license.

Siemens ST 80 / ST PC · 2013

4/119

© Siemens AG 2013

HMI Software
SIMATIC WinCC options
WinCC/Connectivity Pack &
WinCC/Connectivity Station

■ Overview
MES
Online data access
to variables

OPC DA
OPC XML DA
OPC UA DA

ERP

MES

Online messages
forward/acknowledge

OPC A&E

Online data access
to historical data

OPC HDA
OPC UA HDA

VB (.NET),
VB Script, VBA
Database access through
3rd party application

WinCC OLE-DB

SIMATIC WinCC

4

Cross-vendor communication in the automation sector has
always been of primary importance for WinCC. This is even more
true for the release of preprocessed production data for higherlevel information systems (e.g., MES = Management Execution
System, ERP = Enterprise Resource Planning or Office
packages = MS Excel, MS Access etc.). WinCC features
integrated OPC Data Access and OPC XML DA servers for
access to all online values in the system and makes open interfaces available for access to historical WinCC data.
• The Connectivity Pack includes OPC XML DA 1.00, OPC HDA
1.20 (Historical Data Access), OPC A&E 1.10 (Alarm & Events)
and a WinCC OLE-DB interface which even allows remote
computers without WinCC to access WinCC archive and
alarm data.
• The function of the OPC servers (XML DA, HDA and A&E) is
assured by the WinCC/Connectivity Pack. In order to access
data in the database via WinCC OLE-DB/OLE-DB, you will
also need a license for the WinCC/Connectivity Pack.

■ Benefits
• Access to variables, historical WinCC data, alarm data and
user archives from any computer
• Options for analyzing and evaluating process data with
specialist tools or user-defined applications
(e.g., via VisualBasic)

4/120

Siemens ST 80 / ST PC · 2013

MS SQL Server

G_ST80_XX_00066

WinCC/ConnectivityPack

• A Connectivity Pack license is required for every
WinCC system to be accessed.
• If the Connectivity Station is used, an additional Connectivity
Pack license does not have to be installed on the WinCC
systems that are accessed. The Connectivity Station functions
autonomously and does not require a WinCC installation on
the computer.
• For versions below V7.0
Access to WinCC archive and alarm data from a computer
without installed WinCC basic system license or WinCC option
via the interfaces of the Connectivity Pack or Connectivity
Station requires a WinCC/Client Access license on the client
side (see also "WinCC/Client Access License").
• Connectivity Station Option for WinCC V6.2 and higher

© Siemens AG 2013

HMI Software
SIMATIC WinCC options
WinCC/Connectivity Pack &
WinCC/Connectivity Station

■ Function
As an OPC HDA server, WinCC makes historical data from the
WinCC archive system available to other applications. An OPC
HDA client (e.g. a reporting tool) can define the time interval for
the required data by entering a start and end time. OPC HDA
servers also support the generation of a variety of aggregate
functions on the server itself (e.g. standard deviation, variance,
mean values, integral values, etc.), thereby helping to relieve the
load on the network, as only preprocessed data are transmitted.
OPC A&E servers are used to forward WinCC messages (along
with all associated process values) to any client at production or
enterprise control level. Filter mechanisms and subscriptions
ensure that only selected modified data are transmitted.
Acknowledgement is of course also supported.
The WinCC OPC XML DA server makes cross-platform communication between Windows and non-Windows systems possible,
even via the Internet. This enables read and write WinCC online
values (external and internal WinCC variables) to be exchanged
with non-Siemens systems.
WinCC OLE-DB makes standardized and user-friendly access to
WinCC archive data possible (MS SQL Server 2005). In exactly
the same way as access via the OPC HDA and OPC A&E interfaces, access via the WinCC OLE DB provider makes all WinCC
archive data available along with the associated process values
and message/user texts. The WinCC OLE-DB provider also
supports analysis functions such as minimum, maximum,
message hit list, etc.
The WinCC Connectivity Station was designed as a stand-alone
gateway to WinCC server data. It supports access to WinCC
server data over the OPC channels described as well as those
for process values (not alarms) over OLE DB . Access to WinCC
data is transparent, i.e. independent of which server of a
redundant pair is active or whether data have already been
transferred to the central archive server.
Connectivity Station
If no visualization is required at a station, any Windows computer
with access to WinCC via OPC and OLE-DB can be configured
via the Connectivity Station. This permits access to WinCC
stations with server packages from a central computer without
WinCC installation. The WinCC stations can be accessed via the
following interfaces:
• OPC interfaces of the Connectivity Station
• OLE DB interface of the Connectivity Pack
The two access variants are autonomous access options with
different ranges of functions.
OPC interfaces of the Connectivity Station
The Connectivity Station provides interfaces via which you can
access the following using an OPC-Client.
• OPC-DA-Server: tags, e.g. process values
• OPC-HDA-Server: archived process values
• OPC-A&E-Server: alarms

Licensing
You require the "WinCC Connectivity Station" license in order to
utilize the OPC interfaces of the Connectivity Station on a
computer without WinCC installed.
If you only use the OPC interfaces of a WinCC installation, you
only need the "Connectivity Pack" license.
The following table shows the combinations:
New:
WinCC-independent
installation with
Connectivity Station

Standard
installation:
OPC with WinCC

OPC DA

"WinCC Connectivity
Station" license

No license required

OPC HDA

"WinCC Connectivity
Station" license

"WinCC Connectivity
Pack" license

OPC A&E

"WinCC Connectivity
Station" license

"WinCC Connectivity
Pack" license
"WinCC OPC UA HDA
Connectivity Pack"
license

OPC UA DA

The Connectivity Station is planned over NCM PC Manager or
SIMATIC Manager. In Version 7, the Connectivity Station does
not run as service.

■ Ordering data

4

Order No.

WinCC/Connectivity Pack &
WinCC/Connectivity Station
V7.2; for WinCC V7.2
Basic packages
• WinCC/Connectivity Pack V7.2 1)
• WinCC/Connectivity Station V7.2 1)

6AV6371-1DR07-2AX0
6AV6371-1DR17-2AX0

V7.0; for WinCC V7.0,
WinCC V7.0 SP1/SP2/SP3 and
WinCC V7.0 SP1/SP2/SP3 ASIA
Basic packages
• WinCC/Connectivity Pack V7.0 1)
• WinCC/Connectivity Station V7.0 1)

6AV6371-1DR07-0AX0
6AV6371-1DR17-0AX0

V6.2 SP3; for WinCC V6.2 SP3 and
WinCC V6.2 SP3 ASIA
Basic packages
• WinCC/Connectivity Pack V6.2
SP3
• WinCC/Connectivity Station V6.2
SP3
• WinCC/Connectivity Pack V6.2
SP3 ASIA
• WinCC/Connectivity Station V6.2
SP3 ASIA
Upgrade1)
• WinCC/Connectivity Pack V6.x ->
V6.2 SP3
1)

6AV6371-1DR06-2AX0
6AV6371-1DR16-2AX0
6AV6371-1DR06-2AV0
6AV6371-1DR16-2AV0

6AV6371-1DR06-2AX3

Upgrades from V6.x to V7.x are included in the WinCC V7.x upgrades

Siemens ST 80 / ST PC · 2013

4/121

© Siemens AG 2013

HMI Software
SIMATIC WinCC options
WinCC/DataMonitor

■ Overview

4

■ Benefits

• The WinCC/DataMonitor is a component of WinCC Plant
Intelligence and is used for displaying and evaluating current
process statuses and historical data on office PCs with
standard tools such as Microsoft Internet Explorer or Microsoft
Excel. The DataMonitor client is provided with current and
historic process data and alarms by a DataMonitor server.
All staff ranging from machine operators to corporate
managers can use the DataMonitor to obtain information.
• DataMonitor is a suite of Internet-capable tools:
- Process Builder - Tool for simple visualization and
navigation with WinCC screens using WinCC Web Viewer
(WinC Viewer RT) in "view only" mode
- Excel Workbooks - Protocol tool that integrates WinCC
archives and online values into MS Excel and supports
online analysis
- Published Reports - Event- or time-driven execution of Excel
or PDF reports for the output of process data and analysis
results
- Web center - Individual configuration of Internet pages and
summary of information within a portal in terms of WinCC
applications
- Trends and alarms are preconfigured Web Center pages
• DataMonitor does not require manual client installation
because it loads the required components from the
DataMonitor server
• There is no installation required on the client for the
Webcenter, Trends and Alarms functions.
• Licenses for simultaneous access by 1, 3, 10, 25 or
50 DataMonitor clients. Any combination of DataMonitor and
Web Navigator licenses can be used for an application.
• Preconfigured Web Center pages permit ad hoc entry

4/122

Siemens ST 80 / ST PC · 2013

• Information can be compiled online individually during
runtime via the Internet/intranet.
• Efficiently monitor and analyze production lines.
- Display and evaluation of current process states and
historical data on remote office PCs with standard tools such
as Microsoft Internet Explorer or Excel.
- Easy access to production data via the intranet or Internet
- Quick ascertainment of the production situation
- Use of standard products
• Easily collect and distribute information.
- Automated report creation
- No additional configuration effort through direct use of
images from the WinCC project
- No training required for standard products
- Easy exchange of configuration data
• Substantiate decisions with reports.
- Evaluation via ready-made templates for special analyses of
the business processes (e.g. reports, statistics)
- Make bottlenecks transparent
- Individual views for user and situation
- Relative and absolute timeframe for information generation
• View production status anywhere and anytime.
- Individual views of information in production
- View the process and system operation
- Historical data can be compiled online individually
Highlights
• Access to the lower-level servers when installing the
DataMonitor server on a WinCC Client with separate project
(RT128 license)
• Tag logging archive tags can be accessed by means of the
web center function without changing the WinCC configuration system.
• Installation of the DataMonitor web center function on a
WinCC file server
• Dedicated Internet pages can be created for displaying data
with the Webcenter. For this purpose, the following tools which
can be integrated in the Internet sites are available.
- Bar diagram, pie chart, trend curve display
- Process value table and statistics functions for the process
values
- Alarms, hit list for alarms
- Message text display for individual message texts, message
display, selection list of created reports
- Links to internal and external pages
- Display of graphics in converted jpg format
- Display of the WinCC process images
• The analyses can be made with relative or absolute time
specification. This enables comparisons of identical time
periods on different days.
• Reports generated with Excel or the WinCC Report Designer
can be made available on the DataMonitor server or e-mailed
automatically to the relevant group of people based on time
intervals or triggered by events.
• Connections can be established to WinCC Runtime, the
central archive server, and the swapped-out archives

© Siemens AG 2013

HMI Software
SIMATIC WinCC options
WinCC/DataMonitor

■ Benefits (continued)
New in V7.2
• DataMonitor
- In V7.2 or higher, the upgrade license is contained in the
corresponding WinCC version
- Supports Internet Explorer V 7.0, V8.0 and V9.0, including
tabbed browsing.
- Excel reports can be generated with Microsoft Excel
version 2003 / 2007 / 2010

■ Function
• All tools are fully Internet-compatible and, therefore, support
access via any type of connection (LAN, GSM, radio, modem,
Internet, etc.).
• All popular security mechanisms such as login/password,
firewalls, encryption, etc. are supported.
• Users can combine the available tools at will. Licensing only
takes into account simultaneous access to one Web server.
• For display purposes, screens from the WinCC project can be
used or special overview displays configured. Animations,
scripts, navigation and access rights remain valid.
• The WinCC/DataMonitor has purely a display function.
• Company-wide Excel reports, which contain historical and
current process values, can be stored centrally for general
access (reports, statistics). However, local queries to meet
individual requirements can be compiled and executed
online. Plot and tabular representation are supported for
archive data already swapped out.
• Data can be automatically entered into created report
templates and distributed by e-mail or saved on the server.
• The screens are displayed in the WinCC Web Viewer or in the
Internet Explorer in the view only mode of the Web Navigator.
• Enhanced user management for the web center in order to
assign individual Internet pages and created reports to
specific user groups.
• Integrating WinCC process screens on Internet pages without
installation download
• A search function facilitates the management of connections
to the WinCC Server.
• Swapped out archives can be connected and evaluated in the
DataMonitor Web center. Expansion of the display area in the
Web center (Menu Hide function)
• Excel reports created offline can be loaded onto the
DataMonitor server and are thus made available to selected
user groups or for automatic distribution.
• Pre-made elements make the assembly of individual web
pages easier for evaluating information.
• Individual information compilation on one or more Internet
pages with the option of branching to other detail pages.
• Pre-made Internet pages for trend and alarm display enable
an ad-hoc entry to Internet data evaluation.
• An higher-level navigation feature provides a common
framework for the various tools.

■ Ordering data

Order No.

WinCC/DataMonitor V7.2 for
WinCC V7.2 and
WinCC V7.2 ASIA
• 1 client license
• 3 client licenses
• 10 client licenses
• 25 client licenses
• 50 client licenses

6AV6371-1DN07-2LX0
6AV6371-1DN07-2AX0
6AV6371-1DN07-2BX0
6AV6371-1DN07-2CX0
6AV6371-1DN07-2DX0

WinCC/DataMonitor
Powerpacks V7.0
• From 1 to 3 clients
• From 3 to 10 clients
• From 10 to 25 clients
• From 25 to 50 clients

6AV6371-1DN07-2LA0
6AV6371-1DN07-2AB0
6AV6371-1DN07-2BC0
6AV6371-1DN07-2CD0

WinCC/DataMonitor V7.0 for
WinCC V7.0, WinCC V7.0 SP3 and
WinCC V7.0 SP3 ASIA
• 1 client license
• 3 client licenses
• 10 client licenses
• 25 client licenses
• 50 client licenses

6AV6371-1DN07-0LX0
6AV6371-1DN07-0AX0
6AV6371-1DN07-0BX0
6AV6371-1DN07-0CX0
6AV6371-1DN07-0DX0

WinCC/DataMonitor
Powerpacks V7.0
• From 1 to 3 clients
• From 3 to 10 clients
• From 10 to 25 clients
• From 25 to 50 clients

6AV6371-1DN07-0LA0
6AV6371-1DN07-0AB0
6AV6371-1DN07-0BC0
6AV6371-1DN07-0CD0

WinCC/DataMonitor, Upgrade
• from V6.0 to V7.0
• from V6.2 to V7.0
• from V6.x to V6.2 SP3
• from V6.x ASIA to V6.2 SP3 ASIA

6AV6371-1DN07-0XX4
6AV6371-1DN07-0XX3
6AV6371-1DN06-2XX3
6AV6371-1DN06-2XV3

WinCC/DataMonitor V6.2 SP3 for
WinCC V6.2 SP3
• 1 client license
• 3 client licenses
• 10 client licenses
• 25 client licenses
• 50 client licenses

6AV6371-1DN06-2LX0
6AV6371-1DN06-2AX0
6AV6371-1DN06-2BX0
6AV6371-1DN06-2CX0
6AV6371-1DN06-2DX0

WinCC/DataMonitor V6.2 SP3
ASIA for WinCC V6.2 SP3 ASIA
• 1 client license
• 3 client licenses
• 10 client licenses
• 25 client licenses
• 50 client licenses

6AV6371-1DN06-2LV0
6AV6371-1DN06-2AV0
6AV6371-1DN06-2BV0
6AV6371-1DN06-2CV0
6AV6371-1DN06-2DV0

WinCC/DataMonitor,
Powerpacks V6.2
• From 1 to 3 clients
• From 3 to 10 clients
• From 10 to 25 clients
• From 25 to 50 clients

6AV6371-1DN06-2LA0
6AV6371-1DN06-2AB0
6AV6371-1DN06-2BC0
6AV6371-1DN06-2CD0

Siemens ST 80 / ST PC · 2013

4

4/123

© Siemens AG 2013

HMI Software
SIMATIC WinCC options
WinCC/DowntimeMonitor

■ Overview

■ Benefits
• Recording failure times, localizing causes and reasons for
failure times, and monitoring of equipment efficiency.
• Weak-point analysis in production processes and recording of
undesirable process activities.
• Basis for decision making based on performance indicators.
• Identification of the events that lead to cost-intensive failures.
• Entry point for an extended downtime analysis with upgrade
options in the MES software SIMATIC IT.
• Identification of speed and quality losses.
• Complete transparency for all machines as basis for
optimizing the plant's productivity. Faults and bottlenecks are
prevented to increase availability.
• Derivation of specific parameters (KPI - Key Performance
Indicators).
• Integration of respective display instruments (controls) in
WinCC process images.
• Can be utilized for individual machines or even complete
production plants.
• Distribution of evaluations to various people over the web.

4

The entry point to SIMATIC Plant Intelligence can be through
options for the SIMATIC WinCC process visualization system.
The WinCC/DowntimeMonitor is a component of WinCC Plant
Intelligence and is used for monitoring the efficiency and performance of individual machine modules, subsystems and
production lines. The combined elements to be monitored are
designated as equipment. Using the WinCC/DowntimeMonitor,
the machine data management software, standstill time can be
recorded and analyzed centrally in production. For individual
devices, machines or entire production lines, the specific
parameters can be determined this way. Integration into WinCC
ensures complete transparency of all machine and plant data as
a basis for optimizing the plant's productivity.
The process values are read directly from WinCC and are
connected with the respective analysis function.
• The SIMATIC WinCC DowntimeMonitor can be installed on a
WinCC single station, WinCC Server or WinCC Client with
project (RT128 license), and consists of an Engineering Client
as well as a Runtime User interface.
• All engineering operations are performed using a graphic
Engineering Client. The Engineering Client is called up from
the WinCC Explorer.
• SIMATIC WinCC DowntimeMonitor provides ActiveX control
elements. These are used for displaying the determined
parameters and the progress of the various status over a
certain time period. These controls are integrated in WinCC
process images for presenting results.
• The recorded data is stored in an online database set and can
be moved to an offline database set.
• The basic package consists of the Engineering and Runtime
software and 5 licensed equipment units. Other licenses are
available for up to 25, up to 50, 100 and up to 200 equipment
units.

4/124

Siemens ST 80 / ST PC · 2013

■ Function
• Creation of a time model by defining various time categories
as a basis for the KPI calculation for elements (equipment) to
be evaluated.
• Creation of equipment, as central components for the evaluation by dividing the system into individual groups.
• Creation of a Reason Tree for detailed display of reasons for
downtimes.
• Allocation of the system status in the controller to the time
categories and Reason Trees defined in the DowntimeMonitor.
• Storing the system status for calculating and presenting Key
Performance Indicators.
• The following pre-defined Key Performance Indicators are
available: Availability, change-over, cycle time, failure time
loss, duration, effective performance, maintenance, Mean
Time Between Assist (MTBA), Mean Time Between Failures
(MTBF), Mean Time To Assists (MTTA), Mean Time To Repair
(MTTR), failure time frequency, Overall Equipment Effectiveness (OEE), performance rate, production duration, quality
rate, speed loss, Total Efficient Equipment Performance
(TEEP), utilization.
• Integration of three new controls Gant View, KPI View, and
Table View in WinCC for the display of results for one or more
equipment units.
• The WinCC DowntimeMonitor Gant View presents the
equipment status development within a certain time period.
• The WinCC DowntimeMonitor KPI View shows the distribution
of failure times and the Key Performance Indicators in a trend,
bar, segmented bar charts or Pareto chart using historical
data.
• The WinCC DowntimeMonitor Table View shows raw data for
failure times and analyzes it in the selected time period. The
user can utilize these control elements to enter, change,
distribute or combine and comment on failure times manually.
• The controls can be displayed on intranet or Internet using the
option WinCC/Web Navigator.

© Siemens AG 2013

HMI Software
SIMATIC WinCC options
WinCC/DowntimeMonitor

■ Ordering data
WinCC/DowntimeMonitor
V7.0 SP3
for WinCC V7.0 SP3 and
WinCC V7.0 SP3 ASIA
• 5 equipment units
• 25 equipment units
• 50 equipment units
• 100 equipment units
• 200 equipment units

Order No.

Order No.

6AV6372-1DB07-0BX0
6AV6372-1DB07-0DX0
6AV6372-1DB07-0FX0
6AV6372-1DB07-0HX0
6AV6372-1DB07-0KX0

WinCC/DowntimeMonitor
V1.0 SP1
for WinCC V6.2 SP2 and
WinCC V6.2 SP2 ASIA
• 5 equipment units
• 25 equipment units
• 50 equipment units
• 100 equipment units
• 200 equipment units

6AV6372-1DB06-2BX0
6AV6372-1DB06-2DX0
6AV6372-1DB06-2FX0
6AV6372-1DB06-2HX0
6AV6372-1DB06-2KX0

WinCC/DowntimeMonitor
Powerpacks V7.0
• From 5 to 25 equipment units
• From 25 to 50 equipment units
• From 50 to 100 equipment units
• From 100 to 200 equipment units

6AV6372-1DB07-0BD0
6AV6372-1DB07-0DF0
6AV6372-1DB07-0FH0
6AV6372-1DB06-2HK0

WinCC/DowntimeMonitor
Powerpacks V1.0
• From 5 to 25 equipment units
• From 25 to 50 equipment units
• From 50 to 100 equipment units
• From 100 to 200 equipment units

6AV6372-1DB06-2BD0
6AV6372-1DB06-2DF0
6AV6372-1DB06-2FH0
6AV6372-1DB06-2HX0

WinCC/DowntimeMonitor upgrade
• V1.x to V7.0 SP3

6AV6372-1DB07-0XX4

Note
WinCC V7.2 is not supported.

4

Siemens ST 80 / ST PC · 2013

4/125

© Siemens AG 2013

HMI Software
SIMATIC WinCC options
WinCC/Event Notifier

■ Overview

■ Benefits
• Simple operation, configuration and planning of notifications
thanks to handling like the Microsoft Office Calendar
• Easy configuration of the notifications including support of the
WinCC Runtime languages by connecting to the WinCC alarm
system
• Configuration of recurring events taking account of configurable public holidays, vacation periods, and maintenance
periods
• Secure operation of the plant taking account of different
authentication levels
• Clear display and intuitive operation at runtime by means of
Calendar Control
• Flexible use in all typical WinCC plant configurations, single
station, client/server, redundant systems, WebNavigator

■ Function

4

• Option for SIMATIC WinCC for notifying selected persons by
e-mail in specified time slots
• Notification depends on events occurring in the WinCC Alarm
System.
• Escalation levels, i.e. Group 2 is only notified when nobody
"on site" or from Group 1 has reacted within a specified time.
• Final notification of all persons previously notified in
connection with the specific event about the reaction that has
taken place
A license is only necessary on the server (or single user system).

The WinCC Event Notifier enables the following to be configured
in a clear and user-friendly manner via the Calendar Options
Editor in the WinCC Explorer:
• The e-mail service for sending and receiving messages
• The messages by selecting configured messages in the
WinCC Alarm System as well the setup and contents of the
message by selecting the message blocks
• Contacts by selecting predefined persons from the WinCC
user administration.
In a calendar it is then possible to select the persons to be
notified within in the opened time slot from the existing contacts.
If several persons or groups of persons are set up for the same
time slot, escalation levels can be implemented by assigning
different escalation times (= dead time before notification). The
period represented by the calendar can be freely selected.
Recurring events can be defined as serial events with any
desired exceptions.
The calendar can also be integrated as .Net Control in WinCC
screens; the appearance of the calendar controls at runtime is
configurable. Via the calendar control, you can create time slots
during runtime with contacts who should be notified upon occurrence of the configured events in the WinCC Alarm System. In
addition, the calendar control allows the creation of new
contacts by means of selection from the WinCC user
management.
The Event Notifier is easy and intuitive to operate and supports
drag & drop during configuration and runtime.

■ Ordering data

Order No.

WinCC/Event Notifier
• for WinCC V7.2
• for WinCC V7.0 SP3

4/126

Siemens ST 80 / ST PC · 2013

6AV6372-1DD07-2AX0
6AV6372-1DD07-0AX0

© Siemens AG 2013

HMI Software
SIMATIC WinCC options
WinCC/IndustrialDataBridge

■ Overview
WinCC V7
WinCC Professional
SIMATIC NET OPC Server
OPC DA & OPC XML DA

Online
Data Exchange

Microsoft Office
MS Excel
File (csv)

Online
Data Storage

Microsoft Office
MS Access

Online
Data Exchange

Microsoft SQL Server

Online
Data Reading

My Oracle
My SQL

Data Export

SIMATIC WinCC
OPC DA
WinCC User Archive

• The WinCC/IndustrialDataBridge option uses standard interfaces in order to connect the automation world with the world
of IT and ensure two-way information flow. Typical examples of
such interfaces are OPC in the field of automation and SQL
database interfaces in the world of IT.
• With the SIMATIC WinCC/IndustrialDataBridge, simple
configuration/parameterization of communication connections between various data sources and data destinations can
be created. The IndustrialDataBridge can be integrated into
WinCC and can also be used in stand-alone mode
(not in conjunction with WinCC).
• For example, SIMATIC WinCC with its OPC DA server
interface is the data source and an external database is the
data destination.
- Highly flexible, thanks to support for various database
formats and standard interfaces
- Fast and secure thanks to configuration instead of
programming

G_ST80_XX_00067

WinCC/IndustrialDataBridge

MS SQL Server
OLE-DB
(Alarm-, Tag logging)

• In addition to access to WinCC variables, access to
messages, process values and user archive data
(in the WinCC database) is also supported.
• WinCC/IndustrialDataBridge can be used as stand-alone
application with its standard interfaces.
• Option from WinCC V6
• For versions below V7.0
On a computer without a license for the WinCC basic
system or a WinCC option, which is to be accessed in
read/write mode by the option WinCC/IndustrialDataBridge,
a WinCC Client Access License is required
(see also "WinCC/Client Access License").

■ Benefits
• Connecting the automation level with the IT world
• Integration of systems from different manufacturers via a host
of standard interfaces (including OPC, OLE-DB, Office
formats)

• Simple configuration with standard software without
programming and thus at low cost
• High-performance data transfer between several systems
simultaneously

■ Design
The software comprises a configuration environment and a
runtime environment. The different data interfaces are integrated
via software modules. In each case, one module is required as
the data source and one module as the data destination. The
different modules can be combined in any way.

The connections between data source and data destination are
created in the configuration environment.
In the runtime environment, the IndustrialDataBridge establishes
the connection autonomously and transfers the data of the linked
variables.

Siemens ST 80 / ST PC · 2013

4/127

4

© Siemens AG 2013

HMI Software
SIMATIC WinCC options
WinCC/IndustrialDataBridge
Interfaces:

■ Function

4

• IndustrialDataBridge establishes a link between the source
and destination interfaces and transfers data on the basis of a
change in value, once a configurable period of time has
elapsed or when a specific event occurs.
• IndustrialDataBridge exchanges data between automation
systems from different vendors, e.g., via OPC. The connection
of OPC servers via IndustrialDataBridge enables communication between a variety of devices, data sources and data
destinations. The OPC international interface standard is the
key to open systems both now and in the future. Thanks to
IndustrialDataBridge, OPC data exchange can already be
supported.
• WinCC supports access to variables, tag logging, alarm
logging and user archive data.
• Storage of process data in Office formats such as Excel or
Access. Databases can also be integrated for the archiving of
larger aggregates.
• One of the features of IndustrialDataBridge is a Send/Receive
interface supporting data transfer to SIMATIC S5/S7 stations
or other Send/Receive-compatible devices.
• IndustrialDataBridge enables SCADA and control systems
from different vendors to be linked via the OPC interface.
Communication via RFC1006 or Send/Receive is also
supported.
• SQL databases are available as data destinations for
production data acquisition. Data can be transferred from the
data source on an event-driven basis with the OPC module or
sent directly from the PLC with the Send/Receive module.
• Cyclic data archiving can be implemented via the OPC Data
Access, WinAC ODK or Send/Receive data sources and the
SQL database data destinations. On the database side,
various transmission mechanisms are supported.
• Individual control during runtime for each
IndustrialDataBridge connection
(start, stop, connect, and disconnect).
• Integration of IndustrialDataBridge runtime control in
WinCC screens if IDB is installed on a WinCC station.
• Independent CSV files are created if a configurable number of
entries is reached or the value of a WinCC tag changes.
• Block transfer for databases through support for the operators
"<" and ">" in the Select instruction.
• Available providers (data sources) can be connected to any
consumers (data destinations) (see table, below)
New functions in Version 7.2:
• Faster configuration due to new configuration interface
• OPC XML DA Provider / Consumer (data exchange via the
Internet using HTTP and SOAP)
• Support for Asian languages (Simplified Chinese, Japanese)
• Unicode support
• Getting Started for data exchange between User Archive and
Microsoft Access
• For installation in combination with the WebNavigator Server,
the IndustrialDataBridge can be controlled via the Internet

4/128

Siemens ST 80 / ST PC · 2013

The table below shows the possible data sources and destinations
Provider (data sources)

Consumer (data destinations)

• MS Access 2003, 2007, 2010

• CSV, TXT

• MS SQL server 2005, 2008,
2008 R2

• MS Access 2003, 2007, 2010

• MySQL ODBC 3, 5, 5.1, 5.5

• MySQL ODBC 3, 5, 5.1, 5.5

• Oracle 8i, 10g, 11g

• Oracle 8i, 19g, 11g

• OPC Data Access 3.0,
OPC XML 1.0

• MS Excel

• Send / Receive

• MS SQL server

• OPC Data Access Server (internal)

• WinCC OLE DB V7.2

• OPC Data Access 3.0,
OPC XML 1.0

• WinCC User Archive V7.2

• Send / Receive
• WinCC User Archive V7.2

■ Ordering data

Order No.

WinCC/IndustrialDataBridge
V7.2, option for WinCC V7.2
For data exchange with databases
and OPC servers; language
versions: German, English, Chinese
simplified, Japanese
• with 128 tags
• with 512 tags
• with 2048 tags
• with 10000 tags

6AV6371-1DX07-2AX0
6AV6371-1DX07-2BX0
6AV6371-1DX07-2CX0
6AV6371-1DX07-2DX0

V7.0 SP1, option for WinCC V7.0
SP3
For data exchange with databases
and OPC servers; language
versions: German/English
• with 128 tags
• with 512 tags
• with 2048 tags
• with 10000 tags

6AV6371-1DX07-0AX0
6AV6371-1DX07-0BX0
6AV6371-1DX07-0CX0
6AV6371-1DX07-0DX0

WinCC/IndustrialDataBridge
Powerpack V7.2
• from 128 to 512 tags
• from 512 to 2048 tags
• from 2048 to 10000 tags

6AV6371-1DX07-2AB0
6AV6371-1DX07-2BC0
6AV6371-1DX07-2CD0

WinCC/IndustrialDataBridge
Powerpack V7.0
• from 128 to 512 tags
• from 512 to 2048 tags
• from 2048 to 10000 tags

6AV6371-1DX07-0AB0
6AV6371-1DX07-0BC0
6AV6371-1DX07-0CD0

WinCC/IndustrialDataBridge
upgrade
• from V7.0 to V7.2
• from V6.x to V7.2
• from V6.x to V7.0 SP3

6AV6371-1DX07-2XX3
6AV6371-1DX07-2XX4
6AV6371-1DX07-0XX4

WinCC/IndustrialDataBridge
V6.1, option for WinCC V6. 2
For data exchange with databases
and OPC servers; language
versions: English/German
• with 128 tags
• with 512 tags
• with 2048 tags
• with 10000 tags

6AV6371-1DX06-1AX0
6AV6371-1DX06-1BX0
6AV6371-1DX06-1CX0
6AV6371-1DX06-1DX0

WinCC/IndustrialDataBridge
Powerpack V6.1
• from 128 to 512 tags
• from 128 to 2048 tags
• from 128 to 10000 tags
• from 512 to 2048 tags
• from 512 to 10000 tags
• from 2048 to 10000 tags

6AV6371-1DX06-1AB0
6AV6371-1DX06-1AC0
6AV6371-1DX06-1AD0
6AV6371-1DX06-1BC0
6AV6371-1DX06-1BD0
6AV6371-1DX06-1CD0

© Siemens AG 2013

HMI Software
SIMATIC WinCC options
WinCC/IndustrialX

■ Overview

■ Benefits
• Easy creation using configuration wizards
• Quick entry due to the use of standards: ActiveX technology,
creating with the aid of Visual Basic
• Central creating and changing of object displays of the same
type (typing) saves time and money
• Configuring of intelligent, sector-specific objects (graphic
illustration and logical processing) with know-how protection
• Can be used in versatile ways: in WinCC screens and other
Windows applications (e.g. Internet Explorer, Excel)
Innovations of V7.0
Support of Visual Studio 2005 (.NET)

■ Application
IndustrialX controls create standardized presentations and allow
flexible customization to the requirements of a wide range of
applications, e.g. applications in the chemical, glass or paper
manufacturing industries.
• WinCC/IndustrialX makes it easier to develop a solution for a
visualization task by allowing customized objects to be
standardized
• A license must be installed on each development computer
(current version of Visual Basic must be installed on the development computer)

■ Function
• Configuring intelligent, industry-specific objects (graphic
illustration and logical processing) with know-how protection
• Automatic object supply with WinCC data structures
(templates)
• Creation of Web Navigator-compatible, customer-specific
ActiveX components with active process data supply
• Integration into WinCC via structure names

■ Ordering data

Order No.

WinCC/IndustrialX
• V7.0; for WinCC V7.0 and V6.x

6AV6371-1EL17-0AX0

Note
For WinCC V7.2, the WinCC/IndustrialX option is part of the
WinCC/ODK option.

Siemens ST 80 / ST PC · 2013

4/129

4

© Siemens AG 2013

HMI Software
SIMATIC WinCC options
WinCC/Open Development Kit (ODK)

■ Overview

■ Function

WinCC/ODK (Open Development Kit)
• WinCC option for utilization of the exposed programming interfaces that can be used to access data and functions of the
WinCC configuration and WinCC runtime system
• The interfaces are designed as "C-Application Programming
Interface" (C-API)
• Scope of delivery:
- CD-ROM with examples
- Voucher for a one-day intensive workshop

■ Benefits
• Individual system expansions via an open standard
programming language
• Access to data and functions of the WinCC configuration and
runtime system
• Development of your own applications and add-ons for the
WinCC basic system
New in V7.0
• Support for Visual Studio 2005 (.NET)

4

New in V7.2
• UNICODE support
• Support for Visual Studio 2008, 2012

4/130

Siemens ST 80 / ST PC · 2013

The API functions are configuration and runtime functions, and
include:
• MSRTCreateMsg: Creates a message
• DMGetValue: Gets the value of a variable
• PDLRTSetProp: Sets the object properties in a display
They can be used in the following places:
• within WinCC, for example in global scripts or as part of C
actions in the Graphics Designer,
• in Windows applications in the programming language C
(the current version of Microsoft Visual C++ is necessary as a
development environment for WinCC).

■ Ordering data
WinCC/ODK
• V7.2; for WinCC V7.x
• V7.0; for WinCC V7.0 and V6.x

Order No.
6AV6371-1CC07-2AX0
6AV6371-1CC07-0AX0

© Siemens AG 2013

HMI Software
SIMATIC WinCC options
WinCC/ProAgent

■ Overview

■ Ordering data

Order No.

SIMATIC WinCC/ProAgent
• V7.2; for WinCC V7.2
• V7.0 SP3; for WinCC V7.0 SP3
SIMATIC WinCC/ProAgent
Upgrade
• to SIMATIC WinCC/ProAgent V7.2
• to SIMATIC WinCC/ProAgent V7.0
SP3

6AV6371-1DG07-2AX0
6AV6371-1DG07-0AX0

6AV6371-1DG07-2AX3
6AV6371-1DG07-0AX4

3B67B;;B

67(3

• Precise and rapid process fault diagnostics in plants and
machines for SIMATIC S7 and SIMATIC HMI
• Standardized diagnostics concept for various
SIMATIC components
• No further configuration for diagnostics functionality
• Reduces PLC memory and processor usage

4

Note
For further details, see "SIMATIC ProAgent process diagnostics
software"

Siemens ST 80 / ST PC · 2013

4/131

© Siemens AG 2013

HMI Software
SIMATIC WinCC options
WinCC/Redundancy
• Option for SIMATIC WinCC, supporting the parallel operation
of two interfaced WinCC single-user systems or process data
servers for mutual monitoring
• If one of the two server PCs or one of the two WinCC stations
fails, the second one will take over control of the entire system.
Once the failed server or station is restored to operation, the
content of all the message and process value archives are
copied to it.
• One WinCC/Redundancy package is required for each
redundant pair of servers.

■ Overview
~•jj
j“Œ•›š

shu

■ Benefits

~•jj
zŒ™Œ™š
wyvmpul{

G_ST80_XX_00082

wyvmpi|z

■ Function
Normally, two WinCC stations or process data servers run in
parallel. Each station has its own process connection and its
own data archives. WinCC/Redundancy ensures automatic
matching of system and user archive data.

~•jj
j“Œ•›š

4

• Increased system availability with continuous data integrity
• Automatic changeover of client in the event of failure of a
server or failure of the communication to a server
• Continuous operator control and visualization thanks to
automatic client changeover to the intact server
• Automatic updating of all archives in the background after
rectification of the fault

If one of the two server computers or WinCC stations fails, the
second will take over the archiving of messages and process
data, thereby ensuring seamless data integrity. In client/server
mode, the clients are automatically switched from the failed
server to the redundant partner. This ensures continuous plant
visualization and operation on every operator station.

shu
~•jj
zŒ™Œ™š

When the failed partner resumes operation, all process values,
messages and data archived during the fail period are automatically matched with the partner. This process runs in the
background and does not affect plant continuity. Once this is
complete, two equivalent servers/stations will be available
again.

wyvmpul{

G_ST80_XX_00083

wyvmpi|z

Communication with the SIMATIC S7 can also be configured with
redundancy (an H Series SIMATIC S7 is required) by plugging in
two communication modules and configuring two communication paths (S7-REDCONNECT software package). The use of
failsafe H Series SIMATIC S7 can, if required, further increase
availability at control level.

■ Ordering data
~•jj
j“Œ•›š

SIMATIC WinCC/Redundancy
• Option for SIMATIC WinCC V7.2,
Runtime software, single license
for 2 installations
• Option for SIMATIC WinCC V7.0,
Runtime software, single license
for 2 installations
• Option for SIMATIC WinCC V6.2,
Single license for 2 installations

shu
~•jj
zŒ™Œ™š
wyvmpul{

G_ST80_XX_00084

wyvmpi|z

4/132

Siemens ST 80 / ST PC · 2013

Order No.
6AV6371-1CF07-2AX0

6AV6371-1CF07-0AX0

6AV6371-1CF06-2AX0

© Siemens AG 2013

HMI Software
SIMATIC WinCC options
WinCC/Server

■ Overview

WinCC Client

WinCC Client

WinCC Client

TERMINAL BUS TCP/IP

PROCESS BUS

G_ST80_XX_00005

WinCC Server

• Option for SIMATIC WinCC, which permits the configuration of
a powerful client/server system
• One of the following operating systems must be available to
install the option on the server: Windows Server 2003 (for V6)
or Windows Server 2003 R2 (for V6.2 / V7.0 / V7.2) or Windows
Server 2008 (for V7.0 with SP2 and higher or V7.2). When
using Windows XP Professional and Windows 7 SP1, no more
than 3 clients can be connected.
• A number of coordinated HMI stations can be operated in a
single group with networked automation systems
• Client/server solution:
- One server can supply up to 32 connected clients with
process and archive data, messages, images and reports
- Depending on the size of the plant, up to 12 servers
(or up to 18 in version 7.2 or higher) can be used.
- 32 clients (max. 12 or 18 redundant WinCC servers) possible
per system
• Requirement:
Network connection (TCP/IP) between the server PC and the
connected clients. 1)
• One license is required for each server.
1)

One of the following operating systems is installed on one WinCC server:
Windows Server 2003, Windows Server 2003 R2 or Windows Server 2008.
Max. 3 clients with Windows XP Professional and Windows 7 SP1.

■ Benefits
• Plant-wide scalability from the single-user system to the
client/server solution
• Significantly higher quantity framework, relieving the
individual servers and better performance due to distributing
the complete application or tasks over several servers
• Low-cost configuration on the client is possible
(the minimum RC license is sufficient)

4

■ Application
In a complex plant, WinCC can also be configured as a
distributed system according to requirements:
• Functional distribution (e.g. message servers, archive
servers, etc.) or
• Distribution according to the physical plant structure
(e.g. body-in-white, paintshop, etc.)

■ Function
Each client can access more than one server at a time. Clients
can also be used for configuration on the server.
A configuration of WinCC clients as a central Web server - as a
distributed system if required - with an overview of all server
projects in the system is also possible.
For WinCC clients, only the smallest runtime license RT128 is
required. In order to also configure on WinCC clients, the
smallest complete license RC128 is required. Remote configuration is possible if WinCC clients without their own project
(Uniclients) on the server project are configured. This makes it
possible to configure inexpensive operator and configuration
stations in a network.

■ Ordering data

Order No.

SIMATIC WinCC/Server
• Option for SIMATIC WinCC V7.2,
Runtime software, single license
• Option for SIMATIC WinCC V7.0,
Runtime software, single license
• Option for SIMATIC WinCC V6.2,
Single license

6AV6371-1CA07-2AX0
6AV6371-1CA07-0AX0
6AV6371-1CA06-2AX0

Siemens ST 80 / ST PC · 2013

4/133

© Siemens AG 2013

HMI Software
SIMATIC WinCC options
WinCC/TeleControl

■ Overview
WinCC/TeleControl for WinCC V7.0 SP2 supports connection to
outlying stations (Remote Terminal Units = RTUs) via telecontrol
protocols.

■ Benefits
WinCC/TeleControl for WinCC V7.0 SP2 cannot only integrate
newly configured RTUs, it can also integrate units which already
exist in outlying areas by means of DNP3 or IEC 870-5-101/104
drivers.
For communication with the outstations, WinCC/TeleControl for
WinCC V7.0 SP2 uses the SINAUT ST7 and DNP3 protocols
(both via serial and TCP/IP communication connections) as well
as IEC 870-5-101 (serial) and IEC 870-5-104 (Ethernet TCP/IP).
The serial RTU link is possible via the following components,
which can be connected directly via WinCC (single station or
server):
• SINAUT TIM communication modules
(SINAUT ST7 telecontrol protocol)
• TCP/IP serial converter (telecontrol protocols DNP3, Modbus
(not released for WinCC TC), IEC 870-5-101)
Equipment from MOXA or Lantronix, for example, can be used
as TCP/IP serial converters.

4

By means of Ethernet TCP/IP, the RTUs can be connected
directly or via TCP/IP WAN routers to the SIMATIC WinCC system
bus (SINAUT ST7, DNP3, IEC 870-5-104 telecontrol protocols).
When using the SINAUT ST7 telecontrol protocol, the SINAUT
TIM communication module can be used in addition to the
TCP/IP WAN router or as an alternative.

■ Application
Telecontrol communication over the wide area network is largely
determined by the communication infrastructure which already
exists. Various transmission media such as dedicated line,
analog or digital telephone networks, wireless networks (GSM or
private), DSL or GPRS can also be combined with each other.
SINAUT ST7 telecontrol protocol
Detailed information for implementing telecontrol applications
with the SINAUT ST 7 telecontrol protocol via the Industry Mall.
IEC 870-5-101/-104 telecontrol protocols
Detailed information for implementing telecontrol applications
with the IEC 870-5-101/-104 telecontrol protocols via the
Industry Mall.
DNP3 telecontrol protocol
WinCC/TeleControl for WinCC V7.0 SP2 also supports the DNP3
telecontrol protocol. Widely distributed outstations (RTUs) can
be controlled and monitored with the DNP3 telecontrol protocol
via serial or Ethernet TCP/IP communication links by means of
the telecontrol center in SIMATIC WinCC. The control center
integrated with SIMATIC WinCC TeleControl into the SCADA
system is the master during telecontrol communication. The
slaves are represented by the outstations. SIMATIC S7-300/
S7-300F and S7-400/S7-400F/S7-400H/S7-400FH controllers
as well as third-party RTUs can be used as outstations.

4/134

Siemens ST 80 / ST PC · 2013

Further hardware and software components round off the range
of products:
• TIM communication modules
• TCP/IP converters – serial and MD modem modules
• GSM/GPRS components
• TCP/IP routers and switches
• SCALANCE S612 and S613 security modules
• Dedicated-line accessories
• Connecting cables and cables
• Engineering package for configuration of DNP3 data objects,
stations, networks and connections as well as for diagnostics
In order to implement telecontrol networks, basic topologies
including point-to-point, multi-point, star and ring can be
configured using classic or TCP/IP-based media. These can be
combined flexibly independent from existing infrastructure.
Classic WAN media:
• Dedicated line via modem, e.g. SINAUT MD2
• Private wireless networks
• Analog telephone network
• Digital ISDN network
• Mobile radio network GSM
TCP/IP-based WAN media:
• Ethernet networks, e.g. SCALANCE X with fiber-optic cables
• Industrial Wireless LAN with SCALANCE W
• Public networks and the Internet using DSL and/or GPRS

■ Function
Special characteristics of DNP3 communication
• Change-driven data transmission
- Change-driven transmission of process data between RTU
and control center
- Signaling of RTU, control center or connection failure
- Automatic data updating for all communication partners
involved following troubleshooting and following the startup
of the RTU or control center
• Chronological processing of process data
- Time tagging of all data frames at the place of origin allows
process data to be archived by the process control system
in the correct chronological order
- The time of the DNP3 stations in the WAN can be synchronized via SIMATIC WinCC (including summertime/wintertime
switchover)
• Local data storage
- The TIM communication module can temporarily store
(for several hours or even days) message frames should the
connection or the communication partner fail
- Intermediate storage of message frames of lower priority in
the case of priority-controlled data transmission (with dial-up
networks or quantity-dependent data transmission costs)
Operating modes
The DNP3 telecontrol protocol supports the following operating
modes:
• Polling
• Polling with time slot procedure
• Multi-master polling with time slot procedure
• Spontaneous mode in dial-up networks
• Spontaneous mode in the TCP/IP-based WAN

© Siemens AG 2013

HMI Software
SIMATIC WinCC options
WinCC/TeleControl

■ Integration
Integration of WinCC/TeleControl for WinCC V7.0 SP2 into the
WinCC SCADA system offers particular advantages for the water
and waste water sectors, as well as oil and gas sectors,
especially in the case of the following types of plant:
• Freshwater treatment and distribution
• Wastewater treatment plants
• Oil and gas pipelines and water pipes
• Oil and gas drilling fields and the associated treatment plants
In these types of plant, remote outstations such as pumping
stations, valve stations or automated stations for wellheads must
be integrated.
Through the support of communication protocols for RTUs such
as SINAUT ST7, WinCC/TeleControl for WinCC V7.0 SP2
supports the following advanced communication concepts:
• Reduction in the transferred data volume by means of eventcontrolled communication mechanisms for alarm and
measured value information.
• Time-synchronization of RTUs and correct time stamping of all
data in the RTU.
• Tolerance of lower bandwidth, high latency or lack of reliability
of communication lines
• Prevention of data loss due to communications failure through
data backup in the RTU
• Support of communication media with serial interface
(dedicated lines, dial-up connections over analog telephone
lines and ISDN lines), various radio devices (standard, spread
spectrum modulation), microwave and GSM
• Support for TCP/IP-based WANs (Wide Area Networks) such
as DSL, GPRS or Ethernet radio networks
• Support for redundant communication connections
• Expanded communication diagnostics functions for RTU
communication links
• Remote programming of RTUs
• Support for different communication topologies –
point-to-point, multidrop (multistation mode) and hierarchic
network structures
• High quality server redundancy scheme without data loss in
the case of server failure

Through the support of communication protocols for RTUs such
as IEC 60870-5 and DNP3, SIMATIC TeleControl for WinCC V7.0
SP2 supports the following advanced communication concepts:
• Reduction in the transferred data volume by means of eventcontrolled communication mechanisms for alarm and
measured value information.
• Time synchronization of RTUs and correct time stamping of all
data in the RTU.
• Tolerance of lower bandwidth, high latency or lack of reliability
of communication lines
• Prevention of data loss due to communications failure through
data backup in the RTU (not all non-Siemens RTUs support
this)
• Support of communication media with serial interface
(dedicated lines, dial-up connections over analog telephone
lines and ISDN lines), various radio devices (standard, spread
spectrum modulation), microwave and GSM
• Support for TCP/IP-based WANs (Wide Area Networks) such
as DSL, GPRS or Ethernet radio networks
• Support for redundant communication connections
• Expanded communication diagnostics functions for RTU
communication links
• Remote programming of RTUs
• Support for different communication topologies – Point-topoint, multidrop (multistation mode) and hierarchic network
structures
• High quality server redundancy scheme without data loss in
the case of server failure
Outstations/remote terminal units
WinCC/TeleControl for WinCC V7.0 SP2 supports the following
preferred outstations for local distributed automation:
• Controller integrated into ET 200S (IEC 870-5-101/104
telecontrol protocols); for cost-sensitive applications, up to
approx. 30 I/O signals or approx. 200 data points
• S7-300/S7-300F controller (SINAUT ST7, DNP3,
IEC 870-5-101/104 telecontrol protocols); for extremely
flexible configuration, up to 100 I/O signals or
approx. 2000 data points
• S7-400/S7-400F controller (SINAUT ST7, DNP3,
IEC 870-5-101/104 telecontrol protocols);
up to 500 I/O signals or approx. 5000 data points
• S7-400/S7-400F redundant controller (IEC 870-5-101/104 and
DNP3 telecontrol protocols); up to 500 I/O signals or approx.
5000 data points
• Third-party station with the IEC 870-5-101/104 and DNP3
telecontrol protocols (depending on type of station)

Siemens ST 80 / ST PC · 2013

4/135

4

© Siemens AG 2013

HMI Software
SIMATIC WinCC options
WinCC/TeleControl

■ Integration (continued)
The following table provides an overview of the current options
for connecting to these outstations:
Spectrum of outstations and integration versions
Telecontrol protocol

SINAUT ST 7

IEC 870-5-01

IEC 870-5-04

Type of communication

Serial

Ethernet TCP/IP

Serial

Ethernet TCP/IP

Serial

Ethernet TCP/IP

Interface

TIM 4R-IE

TCP/IP WAN
router or/and
TIM 4R-IE

TCP/IP
serial converter

TCP/IP WAN
router

TCP/IP
serial converter

TCP/IP WAN router

ET 200S with
integr. CPU
(corresponding
to S7-314)

-

-

-

-

IM 151-7 CPU or
IM 151-8 PN/DP
CPU
as well as
1 SI module +
SIPLUS RIC library

IM 151-8 PN/DP
CPU
+ SIPLUS RIC
library

S7-300/S7-300F

TIM 3V-IE

TIM 3V-IE

TIM 3V-IE DNP3

TIM 3V-IE DNP3

CP 341
+ SIPLUS RIC
library

CP 343 + IEC on
S7 or integr. PN
interface
+ SIPLUS RIC
library

S7-400/S7-400F

TIM 4R-IE

TIM 4R-IE

TIM 4R-IE DNP3

TIM 4R-IE DNP3

CP 441
+ SIPLUS RIC
library

CP 443 + SIPLUS
RIC library or
integr. PN interface
+ SIPLUS RIC
library

S7-400H/
S7-400FH

-

-

TIM 4R-IE DNP3

TIM 4R-IE DNP3

ET 200M + 2 x CP
341 + SIPLUS RIC
library

CP 443
+ SIPLUS RIC
library

Third-party
station

-

-

Depends on type of station

Depends on type of station

Dial-up lines

•

-

•

-

-

-

Dedicated line and
radio networks

•

•

•

•

•

•

Master/slave

•

•

•

•

•

•

Peer-to-peer

•

•

-

-

•

•

Mesh networks

•

•

•

•

•

•

Time tagging in RTU

•

•

•

•

•

•

RTU time synchronization

•

•

•

•

•

RTU/interface

4

DNP3

•
1)

• 1)

Data buffering in RTU

•

•

•

•

•

Routing with SIMATIC PDM

•

•

-

-

-

•

International standard

-

-

•

•

•

•

1)

Data buffering is limited to two SIMATIC S7 data blocks. Depending on the
SIMATIC CPU, this corresponds to approx. 800 to 3200 buffered frames.

4/136

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

HMI Software
SIMATIC WinCC options
WinCC/TeleControl

■ Ordering data
SIMATIC TeleControl 7.0 SP2
for WinCC Basic Engineering

Order No.
6DL5000-7AA07-0XA5

Software package with
SIMATIC TeleControl for WinCC 7.0
SP2 Engineering Software,
2 languages (English, German),
executable with Windows XP
Professional/Server 2003, Floating
License for one user; electronic
documentation on CD/DVD,
2 languages (English, German)
Type of delivery:
License key memory stick, Certificate
of License incl. terms and conditions,
SIMATIC WinCC Data Medium Package V7.0 + SP2 and CD "WinCC
TeleControl Option V7.0 + SP2"
SIMATIC TeleControl 7.0 SP2
for Server Runtime (6 stations)

6DL5002-7AA07-0XA0

Software package with
SIMATIC TeleControl for WinCC 7.0
SP2 Runtime Software, 2 languages
(English, German), executable with
Windows Server 2003, Single
License for one user; electronic
documentation on CD/DVD,
2 languages (English, German)
Type of delivery:
License key memory stick,
Certificate of License incl.
Terms and Conditions, SIMATIC
WinCC Data Medium Package V7.0
+ SP2 and CD "WinCC TeleControl
Option V7.0 + SP2"
6DL5101-8AX00-0XB0

Runtime license for one
WinCC Single Station or one
WinCC server, Single License
for 1 installation
Requirement:
Software SIMATIC TeleControl 7.0
SP2 for WinCC Server Runtime
(6, 12, 256 stations)
Type of delivery:
License key memory stick,
Certificate of License incl. terms
and conditions
TeleControl DNP3 Driver
6DL5002-7AB07-0XA0

Software package with
SIMATIC TeleControl for WinCC 7.0
SP2 Runtime software, 2 languages
(English, German), executable with
Windows Server 2003, single
license for one user; electronic
documentation on CD/DVD,
2 languages (English, German)
Type of delivery:
License key memory stick,
Certificate of License incl. terms
and conditions, SIMATIC WinCC
Data Medium Package V7.0 + SP2
and CD "WinCC TeleControl Option
V7.0 + SP2"
SIMATIC TeleControl 7.0 SP2
for Server Runtime (256 stations)

6DL5002-7AF07-0XA0

Driver software
for telecontrol protocols
TeleControl SINAUT Driver

Software package with
SIMATIC TeleControl for WinCC 7.0
SP2 Runtime Software, 2 languages
(English, German), executable with
Windows Server 2003, Single
License for one user; electronic
documentation on CD/DVD,
2 languages (English, German)
Type of delivery:
License key memory stick,
Certificate of License incl. terms
and conditions, SIMATIC WinCC
Data Medium Package V7.0 + SP2
and CD "WinCC TeleControl Option
V7.0 + SP2"
SIMATIC TeleControl 7.0 SP2
for Server Runtime (12 stations)

Order No.
SIMATIC TeleControl 7.0 SP2
for Server Runtime
(unlimited stations)

6DL5101-8EX00-0XB0

Runtime license for one
WinCC Single Station or one
WinCC server, single license
for 1 installation
Requirement:
Software SIMATIC TeleControl 7.0
SP2 for
WinCC Server Runtime
(6, 12, 256 stations)
Type of delivery:
License key memory stick,
Certificate of License incl. terms
and conditions
TeleControl IEC 870-5-101/-104
Driver

6DL5002-7AE07-0XA0

Software package with
SIMATIC TeleControl for WinCC 7.0
SP2 Runtime software, 2 languages
(English, German), executable with
Windows Server 2003, single license
for one user; electronic documentation
on CD/DVD, 2 languages
(English, German)
Type of delivery:
License key memory stick, Certificate
of License incl. terms and conditions,
SIMATIC WinCC Data Medium Package V7.0 + SP2 and CD "WinCC
TeleControl Option V7.0 + SP2"

4

6DL5101-8CX00-0XB0

Runtime license for one
WinCC Single Station or one
WinCC server, single license
for 1 installation
Requirement:
Software SIMATIC TeleControl 7.0
SP2 for
WinCC Server Runtime
(6, 12, 256 stations)
Type of delivery:
License key memory stick,
Certificate of License incl. terms
and conditions

■ More information
For an overview of the complete performance spectrum on the
Internet, visit:
Service & Support:
http://www.siemens.com/automation/csi_en_WW/service
(international)

Technical Support (hotline) for Automation & Drives:
http://www.siemens.com/automation/csi_en_WW/
support_request
(international)

Siemens ST 80 / ST PC · 2013

4/137

© Siemens AG 2013

HMI Software
SIMATIC WinCC options
WinCC/User Archives

■ Overview

■ Function
• Input of parameter sets (e.g. operating parameters of a
machine) in WinCC, storage of the sets in the user archive,
and forwarding to the automation level
• Continuous acquisition of production parameters by the
automation system and forwarding of the parameters to
WinCC at the end of the shift
• Acquisition of batch data
• Specification of production parameters
• Management of warehousing data
WinCC user archives are created and assigned data in a userfriendly way using a dedicated editor. Special ActiveX controls
are used for displaying data from the user archives at runtime.
Data sets and fields from user archives are linked to the process
via direct tag linking.

4

• Option for SIMATIC WinCC for managing data sets in user
archives that contain related data.
• WinCC and its automation partners (e.g. a SIMATIC S7
controller) write these data sets and exchange them if
required.
• A license is only required for the server
(or single-user system).
The WinCC/User Archives option can also be used in the context
of the WinCC/Web Navigator (see also WinCC/Web Navigator
option).

WinCC provides functions for free organization of the data
storage in the user archives that affect archives, data sets and
fields. Archives can thus be generated, opened, closed, or
reset, and data sets or field contents can be read, written or
overwritten.
Sequence archives can accommodate batch data, shift
production data, or also product quality data, and meet legal
obligations for verification thanks to gap-free recording.

■ Ordering data

■ Benefits
• Storing and managing of any user data in data sets
• Flexible display using ActiveX controls
• Simple linking of data set fields to the process via direct tag
linking
• Import/export functions for further processing with other tools
(e.g. MS Excel)

4/138

Import and export functions support read-in/out of data via
external applications (e.g. MS Excel). Freely selectable filter
criteria allow clear representation of data sets.

Siemens ST 80 / ST PC · 2013

SIMATIC WinCC/User Archives
• Option for SIMATIC WinCC V7.2,
Runtime software, single license
• Option for SIMATIC WinCC V7.0,
Runtime software, single license
• Option for SIMATIC WinCC V6.2,
Single license

Order No.
6AV6371-1CB07-2AX0
6AV6371-1CB07-0AX0
6AV6371-1CB06-2AX0

© Siemens AG 2013

HMI Software
SIMATIC WinCC options
WinCC/Web Navigator

■ Overview
WinCC
Web client

WinCC
DataMonitor

Internet
WinCC
SCADA client
+ Web server

WinCC
SCADA clients

WinCC
Web client

WinCC
DataMonitor

LAN
WinCC server
(max. 18)

4

PROFINET

G_ST80_XX_00021

PROFIBUS

• Option for SIMATIC WinCC for operator control and monitoring
of plants via the Internet, in-house intranet or LAN
• Configuration from:
- a Web server with the SIMATIC WinCC software as a singleuser, client or server version and a Web client that enables
operator control and monitoring of a current WinCC project
via an Internet browser with ActiveX support. The WinCC
basic system does not have to be installed on the client
computer. It is also possible to use the Web client without
Microsoft Internet Explorer.

• Licensing:
- A license is required in order to use the Web server.
- Licenses are available for access to the Web server
by 1, 3, 5, 10, 25, 50, 100 or 150 clients.
- Low-priced WebNavigator diagnostics licenses are
available for the remote diagnostics via multiple, distributed
Web servers.

Siemens ST 80 / ST PC · 2013

4/139

© Siemens AG 2013

HMI Software
SIMATIC WinCC options
WinCC/Web Navigator

■ Overview (continued)

4

Highlights:
• Installation of the Web server - in distributed systems - also on
a WinCC Client;
- Access to as many as 18 subordinate WinCC stations
(servers) possible
- Web clients offer common views of data on various
WinCC Servers
- If you are using WinCC/Redundancy, the Web clients will
also transfer via the subordinate WinCC servers (requires
WebNavigator server to be installed on the WinCC Client
(RT128) )
- Separating the Web functionality from the WinCC data
servers makes the overall system safer and more scalable in
respect of load. Integrated user management with WinCC:
The configured WinCC operator authorizations are taken into
account on the Web client.
• Access to WebNavigator server from the WebNavigator
TIA Portal series of products.
• Access to user archives.
• VB scripts are supported in the same way as the new objects
and RT functions in WinCC V7.x.
• User-friendly services and tools for distributing customized
objects (controls, files) to Web clients can be supplied for use
as an integration platform. These components can then also
be integrated into cross-Web/Server navigation.
• Distribution of load across a number of Web servers in order
to run several hundred Web clients in a single system; Web
clients are distributed across Web servers automatically.
• Version 7.2 supports Microsoft Internet Explorer Version 8.0
and 9.0, including tabbed browsing. A new license is not
required for separate tabs.
• With the WinCC Web Viewer, the process screens can be
displayed on the Web client independently of the Internet
Explorer. Settings for the client are made on the client itself.
• The WinCC Web Viewer can also be used in conjunction with
the Microsoft Terminal Service.
• From version 7 on, the WebNavigator can also be operated in
"view only" mode and is thus used as tool for operating and
navigating only via WinCC screens by means of the Internet
Explorer.
• The cursor for View only mode can be selected according to
individual requirements.
• Web server logins and logouts are recorded in the alarm and
audit archive.
• There is a gadget available for the Windows 7 operating
system in which selected WinCC process screens can be
displayed. The gadget does not require any additional
WebNavigator license. The WebNavigator server can be
selected direct using the gadget.
• Security is increased by adjustable automatic logout. If an
automatic logout is to take place, an absolute or inactive time
period can be set.
• Runtime in the Web client can be terminated by means of
scripting.

4/140

Siemens ST 80 / ST PC · 2013

■ Benefits
• Operator control and monitoring across long distances and on
different platforms (PC, local panel, mobile PDA)
• Large configurations with up to 150 operator stations
• Fast updating rates thanks to event-driven communication
• Optimally tailored clients for operating and monitoring,
analysis, service and diagnostics
• Acceptance of configuration data for the Web, generally
without changes
• Minimum maintenance costs thanks to centralized software
administration
• High security standards and availability
- Increased security due to separation of WinCC server and
Web server (Web server in secure environment)
- Support for commonly used security mechanisms
(routers, firewalls, proxy servers)
- Access authorization and user administration
New in V7.2
• New license stages for 1, 5, 100, 150 clients and associated
powerpacks 1/3, 3/5, 50/100, 100/150
• Unicode support
• PDL password protection with WebNavigator PDLPad
• Login / logout / register:
• Log user in/out on the WebNavigator client
• Manual logout in the Internet Explorer by means of
ODK C-Script (PWRTLogout function)
• Configurable logout/login in the WinCC RT Viewer

■ Application
In addition to the typical use of the Web Navigator in WANs
(Wide Area Network), the Web Navigator is also suitable for
solving especially low-cost applications. This especially
includes applications that have a pronounced distributed
structure (water/wastewater, oil & gas), or in which access to
process information is only sporadic (building management).
The Web Navigator also permits vertical integration, i.e. a
networked IT landscape with integrated data flow between the
planning and operating levels within a company. Only a
standard browser is required for direct access to current
process information.
The Web Server can have its own dedicated direct process
connection. An alternative is coupling via OPC or the use of a
remote Web Server to a WinCC Client. This simultaneously
increases security and reduces the communication load of the
plant.
In addition to the Standard Web Navigator licensing there is the
so-called Diagnostics Client, with identical functions in principle,
but which is especially suitable for the following applications:
• Remote diagnostics/operation of several unmanned
WinCC stations.
• Central control rooms which monitor multiple Web Servers on
one user interface.
• Power Users that always require guaranteed access to the
server regardless of the number of users already logged on to
the server.

© Siemens AG 2013

HMI Software
SIMATIC WinCC options
WinCC/Web Navigator

■ Design
Licenses for the Web Navigator
The Web Navigator Client software can be installed as many
times as required without the need for a license.
• Server-based licensing;
a license is required in order to use the Web Navigator Server.
Licenses are available for simultaneous access to the Web
server by 1, 3, 5, 10, 25, 50, 100 or 150 clients.
• Diagnostics client licensing;
for optimum-cost access by one or a small number of Web
Navigator Clients to numerous Web servers (e.g., for the
purpose of diagnostics). This client license provides
guaranteed access to Web servers at any time. In respect of
function there is no difference compared with regular Web
Navigator Clients and the two can be mixed.
Web Navigator Clients can:
• Access a number of different web servers or
• Access data on a number of higher-level WinCC stations
simultaneously via a remote Web server

■ Function
The Web Configurator (Wizard) makes setting up and configuring a Web Navigator Server very easy. WinCC process
screens to be visualized via the Internet are created as usual
using WinCC Graphics Designer. Under normal circumstances
the project can be worked on locally without modification. The
Web Publishing Wizard optimizes the screens for transmission
and display on the Internet. A standard browser is all that is
required to display WinCC process screens on the Web Client.
The MS Internet Explorer is used depending on the Web
Navigator version used (tip: start the Internet Explorer in fullscreen mode with the start parameter "-k").
The operator on the Web Client is integrated in the central
WinCC user administration and can operate and monitor the
system according to the configured access rights. The Web
Navigator supports all standard security mechanisms that can
be used for applications on the Internet, e.g. routers, firewalls
and proxy servers.

On the server side, only one Web Navigator Diagnostics Server
license or, alternatively, one Standard Web Navigator license is
required.
Alternatively, a number of Web Navigator Servers with the same
WinCC project can be combined to create a "server farm". This
means that it is possible for several hundred Web clients to have
access to the same database. The service ensures that the
clients accessing are distributed evenly across all servers. If a
server fails the Web client is automatically forwarded to the next
available server.

4

In order to use this functionality you will need to install a Web
Load Balancing license on the Web servers involved. Each Load
Balance package contains 2 licenses.
An inexpensive expansion option for Web Load Balancing is
available for redundant WinCC stations on which the Web
Navigator is also installed. For this purpose, you need to install
a Web Load Balancing Step Up license on the web servers
involved. Each Step Up package contains 2 licenses.
Thin Client solutions
The Web Navigator can also run under Windows Server 2003 or
Windows Server 2008 terminal services. A Windows Server 2003
or Windows Server 2008 (or higher) operating system is
required. This makes it possible to connect SIMATIC Thin Clients
as visualization stations to WinCC, for example.
For this purpose, the Windows terminal services must be
installed on the PC on which the Web client is installed. A
Windows Server 2003 or Windows Server 2008 (or higher)
operating system is required. Up to 25 ThinClients can be
connected to one terminal server.
Applications:
• Mobile devices
• Handhelds
• Rugged on-site visualizations
Hybrid configuration
Web Navigator and DataMonitor clients can be mixed in a single
system.

Siemens ST 80 / ST PC · 2013

4/141

© Siemens AG 2013

HMI Software
SIMATIC WinCC options
WinCC/Web Navigator

■ Ordering data

Order No.

WinCC/Web Navigator

4

V7.2; for WinCC V7.2
• 1 client license
• 3 client licenses
• 5 client licenses
• 10 client licenses
• 25 client licenses
• 50 client licenses
• 100 client licenses
• 150 client licenses

6AV6371-1DH07-2LX0
6AV6371-1DH07-2AX0
6AV6371-1DH07-2MX0
6AV6371-1DH07-2BX0
6AV6371-1DH07-2CX0
6AV6371-1DH07-2DX0
6AV6371-1DH07-2GX0
6AV6371-1DH07-2HX0

WinCC/Web Navigator
Powerpacks V7.2
• From 1 to 3 clients
• From 3 to 5 clients
• From 5 to 10 clients
• From 10 to 25 clients
• From 25 to 50 clients
• From 50 to 100 clients
• From 100 to 150 clients

6AV6371-1DH07-2LA0
6AV6371-1DH07-2AM0
6AV6371-1DH07-2MB0
6AV6371-1DH07-2BC0
6AV6371-1DH07-2CD0
6AV9681-1DH07-2DG0
6AV9681-1DH07-2GH0

WinCC/Web Navigator
Diagnostics Client
• for WinCC V7.2

6AV6371-1DH07-2EX0

WinCC/Web Navigator
Diagnostics Server
• for WinCC V7.2

6AV6371-1DH07-2FX0

WinCC/Web Navigator upgrade
V6.0 to V7.0; V6.2 to V7.0;
V6.2 to V7.2
• For 3, 10, 25, 50 clients
• Diagnostics server and
diagnostics client
• Load Balancing
WinCC/Web Load Balancing V7.2
• Load Balancing
• Load Balancing Step Up

4/142

Included in corresponding WinCC upgrade

6AV6371-1DH07-2JX0
6AV6371-1DH07-2FJ0

Siemens ST 80 / ST PC · 2013

Order No.
V7.0; for WinCC V7.0,
WinCC V7.0 SP1/SP2/SP3 and
WinCC V7.0 SP1/SP2/SP3 ASIA
• Base Pack (3 client licenses)
• 10 client licenses
• 25 client licenses
• 50 client licenses

6AV6371-1DH07-0AX0
6AV6371-1DH07-0BX0
6AV6371-1DH07-0CX0
6AV6371-1DH07-0DX0

WinCC/Web Navigator
Powerpacks V7.0
• From 3 to 10 clients
• From 10 to 25 clients
• From 25 to 50 clients

6AV6371-1DH07-0AB0
6AV6371-1DH07-0BC0
6AV6371-1DH07-0CD0

WinCC/Web Navigator
Diagnostics Client
• for WinCC V7.0

6AV6371-1DH07-0EX0

WinCC/Web Navigator
Diagnostics Server
• for WinCC V7.0

6AV6371-1DH07-0FX0

WinCC/Web Navigator upgrade
V6.0 to V7.0
• For 3 clients
• For 10 clients
• For 25 clients
• For 50 clients

6AV6371-1DH07-0AX4
6AV6371-1DH07-0BX4
6AV6371-1DH07-0CX4
6AV6371-1DH07-0DX4

V6.2 to V7.0
• For 3 clients
• For 10 clients
• For 25 clients
• For 50 clients

6AV6371-1DH07-0AX3
6AV6371-1DH07-0BX3
6AV6371-1DH07-0CX3
6AV6371-1DH07-0DX3

V6.x to V7.0
• For Web Navigator
Diagnostics Client
• For Web Navigator
Diagnostics Server
WinCC/Web Load Balancing V7.0
• Load Balancing
• Load Balancing Step Up

6AV6371-1DH07-0EX4
6AV6371-1DH07-0FX4

6AV6371-1DH07-0JX0
6AV6371-1DH07-0FJ0

© Siemens AG 2013

HMI Software
SIMATIC WinCC options
WinCC/Web Navigator

■ Ordering data

Order No.

WinCC/Web Navigator

System requirements – Web server

V6.2 SP3; for WinCC V6.2 SP3
• Base Pack (3 client licenses)
• 10 client licenses
• 25 client licenses
• 50 client licenses

6AV6371-1DH06-2AX0
6AV6371-1DH06-2BX0
6AV6371-1DH06-2CX0
6AV6371-1DH06-2DX0

V6.2 SP3 ASIA; for WinCC V6.2
SP3 ASIA
• Base Pack (3 client licenses)
• 10 client licenses
• 25 client licenses
• 50 client licenses

6AV6371-1DH06-2AV0
6AV6371-1DH06-2BV0
6AV6371-1DH06-2CV0
6AV6371-1DH06-2DV0

WinCC/Web Navigator
Powerpacks
• V6.2 (for ASIA variants as well)
• From 3 to 10 clients
• From 10 to 25 clients
• From 25 to 50 clients

6AV6371-1DH06-2AB0
6AV6371-1DH06-2BC0
6AV6371-1DH06-2CD0

WinCC/Web Navigator
Diagnostics Client
• for WinCC V6.2 SP3
• for WinCC V6.2 SP3 ASIA

6AV6371-1DH06-2EX0
6AV6371-1DH06-2EV0

WinCC/Web Navigator
Diagnostics Server
• for WinCC V6.2 SP3
• for WinCC V6.2 SP3 ASIA

6AV6371-1DH06-2FX0
6AV6371-1DH06-2FV0

WinCC/Web Navigator upgrade
V1.x to V6.2 SP3
• For 3 clients
• For 10 clients
• For 25 clients
• For 50 clients
V6.x to V6.2 SP3
• For 3, 10, 25, 50 clients 1)
• For Web Navigator
Diagnostics Client
• For Web Navigator
Diagnostics Server
V6.x ASIA to V6.2 SP3 ASIA
• For 3, 10, 25, 50 clients 1)
WinCC/Web Load Balancing V6.2
SP3
• Web Load Balancing (2 licenses)
• Web Load Balancing Step Up
(2 licenses)
1)

■ More information

6AV6371-1DH06-2AX4
6AV6371-1DH06-2BX4
6AV6371-1DH06-2CX4
6AV6371-1DH06-2DX4
6AV6371-1DH06-2XX3
6AV6371-1DH06-2EX3
6AV6371-1DH06-2FX3

6AV6371-1DH06-2XV3

6AV6371-1DH06-2JX0
6AV6371-1DH06-2FJ0

Including upgrade for diagnostics client, diagnostics server, Web Load
Balancing and Web Load Balancing Step Up.

For WinCC/Web Navigator V7.2
• Windows 7 SP1 (32- and 64-bit) Business, Enterprise and
Ultimate (max. 3 clients)
• Windows XP Professional Service Pack 3 (max. 3 clients)
• Windows Server 2003 SP2
• Windows Server 2008 SP2 32-bit
• Windows Server 2008 R2 SP1 64-bit
• Internet Explorer V7.0, V8.0 and V9.0
• Microsoft SQL Server 2008 R2 SP1, 32-bit
(included in the WinCC product delivery)
For WinCC/Web Navigator V7.0
• Windows 7 (32-bit) Business, Enterprise and Ultimate
(max. 3 clients)
• Windows XP Professional Service Pack 3 (max. 3 clients)
• Windows Server 2003 SP2 and Windows Server 2003 R2 SP2
• Windows Server 2008 SP2
• Internet Explorer V6.0 SP1 or SP2 as well as Internet Explorer
V7.0.
• Microsoft SQL Server 2005 SP2 (scope of supply of WinCC)
• WinCC Basic System V7.0 SP2
For WinCC/Web Navigator V6.2 SP3
• Windows 2000 Professional Service Pack 4 (max. 3 clients)
• Windows XP Professional or Service Pack 3 (max. 3 clients)
• Windows Server 2003 SP2 or Windows Server 2003 R2 SP2
• Internet Explorer 6.0 SP1, SP2 or 7.0 (without multitabbing)
• Microsoft SQL Server 2005 SP1 (scope of supply of WinCC)
• WinCC basic system V6.2 SP3
System requirements –Web client
For WinCC/Web Navigator V7.0
• Internet Explorer V6.0 SP1 or SP2 as well as Internet Explorer
V7.0
For WinCC/Web Navigator V6.2 SP3
• Internet Explorer 6.0 SP1, SP2 or 7.0 (without multitabbing)
WinCC Web Navigator V6.2 SP3 ASIA
(requires SIMATIC WinCC V6.2 SP3 ASIA)
The functions included in this version differ from the standard
version of WinCC/Web Navigator V6.2 SP3 as follows:
• This version does not allow an Asian Web Navigator client to
access a non-Asian server and vice versa.

Siemens ST 80 / ST PC · 2013

4/143

4

© Siemens AG 2013

HMI Software
WinCC add-ons und partner management
WinCC add-ons and partner management
Premium Add-ons for Connectivity:
• PM OPEN IMPORT system software
for importing WinCC flexible archives into the WinCC system.
• PM OPEN EXPORT system software
for exporting WinCC data to local storage media or storage
media released in the network.
• PM OPEN TCP/IP system software
permits bidirectional exchange of WinCC data (tags,
messages) with one or more computers that communicate
using the TCP/IP protocol.
• Historian CONNECT ALARM system software
permits importing of messages and alarms from WinCC and
WinCC flexible into the SIMATIC IT Historian.
• TOP Server/TOP Server UCON
expands OPC-based the connection capability for WinCC &
WinCC flexible Advanced (PC based runtime)

■ Overview

C
WinCis-SW
Bas C, RT
R

C
WinCtion
Op

C
WinCd-on
Ad

C
WinCtion
Op

C
WinCd-on
Ad

4

G_ST80_XX_00175

C
WinCtion
Op

C
WinCd-on
Ad

WinCC Premium Add-ons – Solutions for all sectors and
technologies
The basic system is designed to be independent of any specific
technology or industrial sector, to be modular and flexibly
expandable and to permit not only simple single-user applications in machine construction, but also complex multi-user
solutions or even distributed systems with several servers and
clients in plant engineering. WinCC Premium Add-ons are
supplementary products that have been created by competent
partners working in the specifc sectors and technologies and
represent interesting expansions for WinCC.
WinCC Premium Add-ons are not IA (Siemens Industry
Automation) products, but the products of partners who are
committed to complying with certain quality features and
boundary conditions. The Premium Add-ons are checked, for
example, in the Siemens Test Center for their compatibility with
the basic WinCC system and supported in the first instance by
the central Hotline. As they are important application- and
sector-specific add-on products for SIMATIC WinCC, they are
marketed jointly by Siemens and the respective add-on
suppliers. The WinCC Premium Add-on products can be found
on the Internet (see Further Information) and in the "Online
WinCC Premium Add-on Catalog".

4/144

Siemens ST 80 / ST PC · 2013

Premium Add-on for process management:
• PM CONTROL system software
is a recipe system for user-friendly generation and modification of recipes.
• PM QUALITY system software
is an archive system for the administration of job and batchrelated production and process data.
Premium Add-on for sector products:
• Library SENTRON PAC3200 for SIMATIC WinCC
permits seamless integration of the SENTRON PAC3200 multifunctional measuring instrument in WinCC.
• Sm@rtlib function library
provides function blocks for S7-300/400 as well as faceplates
and icons for WinCC and WinCC flexible from the areas of
process industry, HVAC, pharmaceuticals and energy.
• ACRON for WinCC/PCS 7
is used for long-term archiving and logging of process data for
small to medium-sized plants, specifically in the water supply
and treatment industry.
Premium Add-on for configuration tools:
• DCC TranslationEditor
for translating multilingual projects with in-built security,
convenience and globalization features.
Premium Add-on for diagnostics and maintenance:
• Management System Alarm Control Center
for transmitting fault messages via various communication
paths, such as GSM, LAN, e-mail.
• PM MAINT system software
is a tool for the maintenance of production plants.
• PM ANALYZE system software
for analysis of fault and operating messages, as well as
process values.

© Siemens AG 2013

HMI Software
WinCC add-ons und partner management
WinCC add-ons and partner management

■ Overview (continued)

■ More information

Competent partners

WinCC Competence Center

With SIMATIC WinCC, you not only get excellent products to suit
your requirements, but we will also support you with selecting a
partner for your automation solution. In our global network of
Siemens Automation Solution Providers you will always find
competent partners in your neighborhood. In addition, we
implement and support the Siemens-internal WinCC Competence Centers and the WinCC Professionals external system
integrators on the basis of WinCC customer- and industryspecific and economic solutions.

http://www.siemens.com/winCC/competencecenter
Siemens Solution Partner Automation
http://www.siemens.com/automation/solutionpartner
WinCC Premium Add-on
http://www.siemens.com/winCC/addons

WinCC Competence Centers
Mannheim
Emphasis on process management
• Sector-independent solutions and products in the fields:
Production, environmental protection, maintenance and
diagnostics
• Connectivity tools, system integration, connection to SAP R/3
• Support of FDA validation and WinCC ODK
• Support for advanced users with application of ODK and VBA
• Customer-specific software development for panels,
PCs/IPCs, and servers
• Consulting on web technologies, web servers/thin clients,
DataMonitor
• Customer-specific workshops, e.g. VBS, VBA, and all
WinCC options, e.g. Process Historian
• Information Server and other WinCC topics according to
customer requirements

4

Stuttgart
Emphasis on production technology
• Solutions for maintenance management
• Web-based solutions with WinCC
Nuremberg
Solutions in the Oil & Gas, Metal & Mining, Pulp & Paper sectors
• Network and security
• Microsoft Certified
• Migration from COROS to WinCC
• Customized expansions also for WinCC flexible
• Web solutions
• Customer-specific workshops, e.g. training courses for VBS,
VBA, web technologies à Web Server/Thin Client, DataMonitor
à Webcenter Reports, Excell Workbook, and all WinCC topics
as required by the customer (the latter with lead time)
Further information can be found in the Internet at:
http://www.siemens.com/wincc/competencecenter

Siemens ST 80 / ST PC · 2013

4/145

© Siemens AG 2013

HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture

■ Overview

SIMATIC WinCC Open Architecture is a SCADA system for
visualizing and operating processes, production flows,
machines and plants in all industrial sectors.

4

SIMATIC WinCC OA relies throughout on object-oriented structures. Due to this consistent and well-considered use of objectoriented structures, from process pictures to the database, the
engineering costs improve for SIMATIC WinCC OA customers.
Distributed systems enable the connection of up to
2048 autonomous SIMATIC WinCC Open Architecture systems
via one network. Each subsystem can be configured either as
single-user or multi-user system, each of which may be
redundant or non-redundant.
• Current version: SIMATIC WinCC Open Architecture V3.11
Runs on:
- Windows 8 Enterprise (64-bit)
- Windows 7 Ultimate/Enterprise/Professional SP1 (32/64-bit)
- Windows XP SP2/SP3 (32-bit)
- Windows Server 2008 R2 (64-bit)
- Red Hat Linux 5 (32/64-bit)
- OpenSuse 12.1 (32/64-bit)
- Sun Solaris 10 SPARC (32-bit)
- Sun Solaris 10 x86 (64-bit)
- VMWare ESXi Version 4.0.0 & 5.0.0
Note
Native 64-bit support on 64-bit systems.

■ Benefits
• Efficient engineering and flexible plant expansion
- Object orientation
- Unlimited number of data points
- Mass engineering
- Multilingual with UTF-8 support

4/146

Siemens ST 80 / ST PC · 2013

• Object-oriented data model
- Mapping of setpoint values and measured values for a
physical plant object onto a structured data point
- Data point comprises a tree structure with data point
elements
- The individual process values are mapped onto the data
point elements
- Any number of data points can be instanced from one
defined data point structure (data point type), e.g. 20 pumps
of the same type.
- Data point types can be embedded in other data point types,
which enables more complex plant objects to be generated
(e.g. one pump station comprises 2 pumps).
- Graphical plant symbols can be linked with a data point
type, in which case they only need to be drawn once, but can
be used for all instances of the linked type.
- Savings in engineering outlay.
• Freely scalable
- From a small single-user system up to a networked,
redundant high-end system
- Distributed systems of up to 2048 servers
• Platform-independent
- Available for Windows, Linux and Solaris
• Native 64-bit support
- More system memory is usable, due to native 64-bit support
- This means that larger data quantity structures per server
can be processed
• Maximum fail-safety and availability
- Hot standby redundancy
- Disaster recovery system
- SIL3 certification according to IEC 61508
• Platform for customized solutions
- Quick and easy implementation of new processes
- Swift adaptation of the control and visualization of the plant
to current market requirements
- Company-internal programming and in-house developments enable independence and protection of intellectual
property
- Structure of standardized solutions permits continuous use
- Support of brand-labeling
- Individual brand names for OEM developments
• Openness thanks to comprehensive driver and interface
options:
- Modbus serial, Modbus Plus / RS485, RK512, TLS, Teleperm
M, SSI driver, IEC 60870-5-101, -104, DNP3, SINAUT,
PROFIBUS DP, PROFIBUS S7 + MPI, S7 TCP/IP, Modbus
TCP/IP, Ethernet/IP, OPC DA Client & Server, OPC A&E Client
& Server, OPC UA Client & Server (DA, AC), SNMP, BACnet,
API, Kerberus
• Seamless traceability of system states by means of highperformance archiving:
- Data archiving in value archives (internal database format)
- Data archiving in an Oracle database
• Expandable by means of add-ons and solution frameworks:
- Add-on for quick and easy engineering (Etool, AdvS7, etc.)
- Add-on for increasing the availability (DRS, etc.)
- Add-on for clarity in distributed systems (GIS Viewer, etc.)
- Add-on for efficient maintenance management
(AMS, Scheduler, etc.)
- Add-on for mobile operability
(Web Client, Ultralight Client, etc.)
- Add-on for efficient building automation technology
(BacNet, etc.)
- Add-on for the integration of video management

© Siemens AG 2013

HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture

■ Application
The SCADA system SIMATIC WinCC Open Architecture
addresses applications with high demand for customer-specific
adaptations, large and/or complex applications, as well as
projects that demand special system requirements and
functions.
SIMATIC WinCC Open Architecture demonstrates its high
performance in networked and redundant high-end control
systems in particular. Integrated, high-performance communication is guaranteed from the field level to the control station,
from the machine to the company headquarters. In every
situation, high availability, reliable information, fast interaction,
and user friendliness are guaranteed. Applications can also be
changed without interrupting the process. Profitability, efficiency
and safety are therefore always in equilibrium. SIMATIC WinCC
Open Architecture displays its reliability in a wide range of
business-critical applications.

■ Function
SIMATIC WinCC Open Architecture is a very modular SCADA
system. The required functionalities are realized by specific,
functional entities created for various tasks. In SIMATIC WinCC
Open Architecture these units are called "Managers" – they are
also independent processes in software terms.
WinCC OA Manager

Task

Event Manager (EV)

The Event Manager (EV) is the processing center
in WinCC OA. This unit provides a constantly
updated image of all PowerTags in the memory.
Each other functional unit (Manager) that wants to
access the data receives it from the process
image of the Event Manager and does not have to
communicate directly with a controller. Conversely,
a command from an operator station is initially set
only as a value change in the process image of the
Event Manager. The associated driver then forwards it to the corresponding target device
(e.g. PLC) automatically.
The Event Manager is a kind of central data distributor, in effect the communication center for
WinCC OA. Furthermore, this Manager also carries
out the alarm handling and can execute various
arithmetic functions autonomously.

Driver Manager (D)

The lowest level in a WinCC OA System is represented by the process connections, referred to in
WinCC OA as drivers (D). These are special programs that handle the communication with the
control and field level. Since numerous different
forms of communication are possible with the
PLCs or telecontrol nodes, there are different drivers that can be selected. In very simple terms, the
driver is a unit for converting a particular protocol
into the internal communication form of WinCC
OA. The driver reads the current states, measurement or counter values from the field and in the
opposite direction it forwards commands and setpoints to the lower-level controllers (= the term
"control" should be used here and below to represent all possible devices of the basic automation
(PLC, DDC, telecontrol system, etc.)).

With SIMATIC WinCC Open Architecture, ideas can be quickly
and easily converted into new applications. SIMATIC WinCC
Open Architecture is open for independent in-house developments and also enables own product branding.
Thanks to its special system properties, SIMATIC WinCC Open
Architecture meets the highest demands especially in the case
of traffic solutions, building management systems and supply
systems (power, water, oil and gas, etc.).

■ Design
SIMATIC WinCC Open Architecture is available as a single-user
runtime license, multi-user runtime license, Web Client license,
and parameterization and development license. With SIMATIC
WinCC Open Architecture the required license is determined,
among other things, according to the number of inputs and
outputs (I/O).
An "I/O" refers to a data point element (DPE) whose content is
exchanged either by means of drivers (e.g. S7 driver communicates with a PLC), with other software systems. Internal data
point elements, i.e. DPEs without communication to the outside,
are not counted for licensing. The licenses are available either
with an unlimited number of I/Os or with limitations of 500 to
250 000 I/Os.
The multi-user runtime license allows working simultaneously
from different PCs, with the licensing taking place via the server.
The active clients are then counted. The web client and the ultralight client enable the visualization and operation of process
pictures over an exclusively HTTP connection between the
server and the respective web client. The parameterization and
development licenses extend a runtime license with the option of
configuration and parameterization. They each require a server
license.

Data Manager (DB)

The Data Manager (DB) represents the link to
database. On one hand, it involves the parameterization data of an application that is to be stored in
such a database. On the other hand, it involves the
historical recording of changes in values or
alarms. If a user wishes to query historical data at
a later date, then the Data Manager completes this
request and not the database itself.

Siemens ST 80 / ST PC · 2013

4/147

4

© Siemens AG 2013

HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture

■ Function (continued)
WinCC OA Manager

Task

Control Manager
(CTRL)

WinCC OA has numerous options for implementing your own algorithms and processing. The two
most important are the internal language control
(CTRL) and the general application programming
interface (API).
Control is an extremely powerful scripting language. The processing is interpretative, so that no
compilation is required. The syntax is almost identical with ANSI-C, with some modifications for simplification. This is a fully developed, procedural
high-level language with multi-threading (= quasiparallel processing of individual programs; the
system itself carries out the processing check).
The language offers a comprehensive function
library for tasks of the control and visualization
technology. Control can be used as a stand-alone
process (Control Manager), for animation and user
interface design or for standardized, data objectoriented processing functions.
The API (WinCC OA API) represents the most powerful form of functional expansion. It is configured
as a C++ class library and allows the software
developer to implement individual functions as an
independent, additional manager (forecast system, simulation, tools, proprietary databases,
etc. ).
The interface to the user is created by the User
Interface Manager (UI). This comprises a graphics
editor (GEDI), a database editor (PARA) or the
general user interface of the application (Vision
module). The User Interface serves to display values, issue commands or track alarms in the alarm
list. Trends and reports are also usually part of the
UI. From a programming viewpoint, the user interaction in WinCC OA is completely isolated from the
background processing – this is merely a view of
the data of the current process image or the history.

4

UI

UI

UI

Userinterface
Editorr

Userinterface
Runtimee

Userinterface
Runtimee

CTRL

API

Control
manager

API
manager

DB

EV

CON

Database
manager

Event
manager

Connection
to other
systems

D

D

D

Driver

Driver

Driver

Visualization, Operation
UI
GEDI
PARA

= Runtime
= Graphical Editor
= Database Editor

Processing, Control
Control = Script language
Manager = Application
API
Programming
Interface

Process Image, History
Event manager = Communication
and Alarming
Data manager, = History
RDB

Process Interface
Driver: PLC, Field busses, DDC,
Telemetry/RTU, Special drivers

G_ST80_XX_00463

User Interface
Manager (UI)

A WinCC OA System consists of function-specific units, the managers

4/148

Siemens ST 80 / ST PC · 2013

For special tasks such as redundancy, management for
distributed systems, web server, reporting, simulation, COM
etc., further managers are available.
The powerful configuration functions contribute to a reduction of
engineering and training overheads and lead to increased flexibility and operational reliability.
Special functions

Task

Access to external
databases

The database interfaces offer the possibility of
access to external databases.
Under Windows, the link is established via the
ADO Standard. ADO (ActiveX Data Objects) is an
interface developed by Microsoft for vendor-independent access to data sources of all types, primarily databases. The data source for ADO is an
OLE DB Provider, although ODBC-compatible
databases can also be addressed via an internal
wrapper.
In Linux, the Qt library is used as an interface to
relational databases. Access in this case is either
direct via the native DB-API or via ODBC.

Application Programming Interface (API)

The API offers a series of functions that enable
WinCC OA to be extended with special managers.
A manager means a program that communicates
with the system by via a protocol defined by
WinCC OA.

COM (Component
Object Model)

This is a specification for the development of modular software components that can be used by
each COM-compatible application.
COM components can easily be integrated into
such applications and can even be removed from
an application during runtime. COM components
can be programmed in a host of different languages, even though C++ is usually used for this
purpose. The specifications OLE, ActiveX and
DirectX are based on the COM technology.

Control expansion

Expansion that allows C++ functions to be added
to the programming language.

Panel topology/
summation signal

Generation of panel hierarchies/topologies in
existing or new projects and automatic creation of
summation signals of the alarm data points that
are located in the panels of the topology.

Redundancy
(see figure below)

The failure safety in a redundant system is implemented by means of hot standby.
Hot standby is a hardware-independent solution
for high availability. This is a safety concept that
consists of two interconnected server systems.
Both servers are constantly in operation and are
subject to the same functional loading (but only
one server is ever active; the second compares
the data with the primary unit at runtime).
On the failure of one unit, an "on-the-fly
changeover" takes place and the previously
passive server assumes the leading role. This
guarantees access to data or functions at all
times.

© Siemens AG 2013

HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture

■ Function (continued)
Special functions

Task

Special functions

Task

SMS

Allows the sending and receiving of text messages
with WinCC OA.

Drag and Draw

Encryption of panels
and CTRL scripts/
libraries

Allows your panels or scripts to be encrypted,
thereby protecting your knowledge and work.

Several representative graphical objects can be
defined and configured for each plant object in the
data model (data point type). These are pre-configured and need only be moved to the panel via
drag-and-drop when the plant pictures are drawn.
This saves valuable time during engineering.

Script Wizard

Easy-to-use tool that simplifies the creation of animated, graphical plant symbols, which saves time
during engineering.

Distributed systems
(see the diagram
below)

Simple Symbols

Basic package of plant symbols that have been
created using the script wizard. These can be
adapted quickly and easily to the specific requirements of the customer.

Easy Faceplates

Simple parameter assignment of predefined popup windows that display details of the associated
plant symbol. Without any additional drawing outlay, several standard functions per object can be
activated for the detail view (alarm display, trend
display, measured value table, setpoint value
table, address table, notes).

Permits the coupling of two or more autonomous
WinCC OA systems via a network. Each subsystem of a distributed system can be configured
either as a single-user or multi-user system, each
of which may be redundant or non-redundant.
A sub-system in this context means a server on
which an Event Manager is running, whereby in
case of redundancy both redundantly operating
servers are considered as one system.

Operational station 1

UI

UI

Userinterface
Runtime

Userinterface
Runtime

Server 2

CTRL

CTRL

Control
manager

Control
manager

EV
DB

Event
manager

Database
manager

REDU

REDU

Redundancy
manager

Redundancy
manager

Event
manager

D

D

Driver

Driver

Process connection

The diagram shows a detailed representation of the two
computers Server 1 and Server 2. Server 1 is in the management
mode (active) and Server 2 is in hot standby mode (passive).
In the case of redundant operation, the UIs of both operator
stations are connected to both Event Managers, however only
the data of the active system is displayed on both UIs.

Process connection

DB
Database
manager

G_ST80_XX_00479

Message direction

Server 1

ACTIVE

4

Operational station 2

HOT-STANDBY

The Event Manager of the passive system is restricted exclusively to communication with the Event Manager of the active
system for comparison of the process data (it sends no data to
the connected UIs or it discards messages from the drivers – this
can be seen in the figure with the switches on the UIs or on the
passive Event Manager).

Siemens ST 80 / ST PC · 2013

4/149

© Siemens AG 2013

HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture

■ Integration
Integration in automation solutions
SIMATIC WinCC Open Architecture is an open SCADA system
with comprehensive drivers and flexible options for connection
to other external systems.
Depending on the communications protocol and the bus
physics used, specific drivers are used in each case:
• Serial protocols: RK512, 3964R, etc.
• Ethernet: Industrial Ethernet (S7), Modbus TCP
(OpenModbus), Ethernet IP (AB), etc.

• Telecontrol systems: SINAUT, SSI (Ethernet),
IEC 60870-5-101, IEC 60870-5-104, etc.
• Vendor-independent interfaces: OPC UA, etc.
In SIMATIC WinCC Open Architecture, several drivers can be
operated in parallel. These can be of the same type or also of
different types. It is possible in a SIMATIC WinCC Open Architecture system, for example, to establish connections via the
S7 protocol to a SIMATIC controller, via IEC 60870-5-104 to a
telecontrol system, and via OPC DA to any OPC server at the
same time.

Coupling overview

4

Protocol

Description

Protocol

Description

SIMATIC S7

via TCP/IP and MPI

SSI

OPC Client
(Data Access)

• Compatibility with the specifications DA 1.0
and 2.05a
• Connection to inproc, local or remote server
• Connection with up to 20 servers at the same
time
• Monitoring of the connection to the server
and automatic reconnection if the connection
is interrupted.
• Address browsing if supported by the server.
• Benefits of the CALL-R functionality for CALL-R
servers (simplified parameter assignment)

Is used for the interfacing of SAT remote control
systems. The data is exchanged via the LAN
(Ethernet, IEEE 802.3); the frame formats used
are the SSI formats defined by SAT. The SK 1703
telecontrol components with a suitable communication card (KE/ET) are supported.

IEC 60870-5-101, -104

IEC drivers are standardized telecontrol drivers
that can process proprietary frames. IEC stands
for International Electrotechnical Commission,
the international standardization committee for
electrical engineering.
• IEC 60870-5-104 for data exchange via TCP/IP
• IEC 60870-5-101 for serial connection

DNP3

The DNP3 (Distributed Network Protocol 3)
driver is an open, rugged and modern protocol
which exhibits characteristics and strengths similar to the IEC driver. The transfer of any number
of frames with different data types takes place
between the WinCC OA System (Master) and the
remote stations (Slave).

SINAUT

SINAUT (SIemens Network AUTomation) is a
communication protocol for automated monitoring and control of remote process stations on the
basis of SIMATIC S7. Communication takes
place via TCP/IP.

SNMP Manager & Agent

SNMP (Simple Network Management Protocol)
is a protocol for monitoring network elements
(servers, workstations, routers, switches, hubs,
etc.) and their functions.
• SNMP Manager supports SNMP V1, V2, and V3
• SNMP Agent supports SNMP V1 and V2

BACnet over IP – driver

BACnet (Building Automation and Control Networks) is a standardized protocol for building
automation and has been set by the ASHRAE
(American Society of Heating, Refrigerating and
Air-conditioning Engineers) as a guideline to provide a uniform and cross-company standard for
data communication within and between building automation systems.

OPC Server
(Data Access)

OPC Alarms & Events

• Corresponds to Data Access 2.05a specification (reading/writing of online values).
• Is to be started as a manager just like other
drivers.
• The provided DPEs (server -> client) can be
easily and quickly defined via data point
groups.
• DPEs can be declared as readable (read-only
access is permitted; Group OPCRead) or as
writable items (Group OPCWrite).
• Clients can browse the WinCC OA OPC Server
hierarchically.
OPC Alarms & Events (abbreviated to OPC A&E)
is, in addition to Data Access, a further standard
for performing central alarm management on a
cross-vendor basis. OPC A&E is used to ensure
the link to other control systems and the display
of alarms/events in a hierarchical system.

OPC UA
(Unified Architecture)

• The OPC UA client supports the OPC UA standards Data Access and Alarms & Conditions.
• The OPC UA Server supports the OPC UA standards Data Access and Alarms & Conditions.

Modbus TCP

Modbus/TCP is based on the serial Modbus
protocol, which was adapted for TCP/IP.
The Modbus/TCP driver can be used
simultaneously for Modbus/TCP or UNICOS.

Serial: RK512/3964R

Is used for interfacing a PLC via the 3964R/
RK512 protocol

Cerberus

Cerberus is a fire, intrusion and gas alarm system. The Cerberus driver guarantees communication to and from the central fire alarm systems
and building security facilities in the event a fire,
gas or intruder alarm.

The BACnet Standard 2004 is supported in
accordance with the PIC list (see product documentation)
Dynamic Logic – driver

The Dynamic Logic driver communicates
with different Dynamic Logic devices via the
"FSK outstation protocol".

Applicom General
Interface

Applicom is, among other things, a manufacturer
of I/O cards and software tools, with a wide
range of applications in automation engineering.
The Applicom products are compatible with
many common fieldbus systems and communications components.

Further drivers on request or via C++ API

4/150

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture

■ Technical specifications
Type

SIMATIC WinCC Open Architecture V3.11

Type

Operating system

• Windows 8 Enterprise (64-bit)

Functionality/quantity
structure

• Windows 7 Ultimate/Enterprise/Professional
SP1 (32/64-bit)

SIMATIC WinCC Open Architecture

Number of messages

150,000 2)

Message text
(number of characters)

System-limited 1)

• Windows Server 2008 R2 (64-bit)
• Red Hat Linux 5 (32/64-bit)

Message archive

System-limited 1)

Process values per message

1 process value + up to 32 alarm associated
values per message

Constant load of messages,
max.

500/s 2)

Message burst, max.

15,000/10 s every 5 min 2)

• Windows XP SP2/SP3 (32-bit)

• OpenSuse 12.1 (32/64-bit)
• Sun Solaris 10 SPARC (32-bit)
• Sun Solaris 10 x86 (64-bit)
• VMWare ESXi Version 4.0.0 & 5.0.0
Note:
Native 64-bit support on 64-bit systems
PC hardware requirements 1)

Archives
Archive data points

Max. 250,000 per server 2)

Archive types

< 20 parallel logs, different retention period for
each log

Processor type

Intel Pentium or equivalent

Minimum

Intel Pentium IV 1.6 GHz (or better)2)3)

Recommended

• Client: Intel Pentium IV/Core2/i3, 2 GHz2)3)
• Server: Intel Core i3 CPU Dual, 3 GHz2)
• Server large system4): Intel(R) Core(TM) i5/i7
CPU Dual / Quad, 3 GHz2)3)

Data storage format

Oracle or file system

Measured values per second, max.

Server/single-user station: 7,000/s 2) 3)

Minimum

2 GB 2)

Archives

System-limited 1)

Recommended

• Client: 2 GB 2)3)
• Server: 8 GB 2)3)
• Server large system: 16 GB 2)

Type

SIMATIC WinCC Open Architecture

Table size

System-limited by ORACLE database

User archive

RAM

Hard disk
(available memory for
installation)
Minimum

HD with 800 MB available 2)

Recommended

Server large system with local logging:
SCSI LVD Controller, WIDE SCSI / LVD HDD
or comparable storage system with at least
500 MB of available space 2)

Number of screens

System-limited 1)

Number of objects per
screen

System-limited 1)

Number of controllable
fields per screen

System-limited 1)

PowerTags

< 750,000 per server 2)

User administration

Screen and graphics card
(TrueColor)

User accounts

< 4096

Minimum

1024 x 768 2)

Configuration languages

2 (De, En)

Recommended

1280 x 1024 2)

Runtime languages

40 (of which 8 Asian)

Mouse and keyboard

Mouse, keyboard

Multi-user system

DVD drive

for software installation

Server

< 2048 2) 4)

Local power user rights

• for installation
• for operation

Number of clients

< 244 per server 2) 5)

1)

4

Graphics system

For actual use in plants, the hardware requirements are largely dependent
on the project size and the dynamic response of the process variables.
Whenever possible, use rugged, high-quality hardware with corresponding
functionalities such as redundant power supply units or RAID hard disks.
WinCC OA supports dual and multi-processor mode and benefits significantly from the fact that each WinCC OA Manager can be assigned to one
processor core as a system process. At the same time, however, it is
important that the individual cores offer the highest possible performance
(high clocking), since load-critical core processes such as the event
manager run on exactly one core (for this reason, multi-core machines with
low-clocked cores are unsuitable for WinCC OA). As for RAM, CPU and
HDD, the usual rule applies: more is better

2)

System requirements generally only refer to WinCC OA Version 3.11 under
the supported versions of the Windows and Linux operating systems

3)

A precondition for the minimum requirement is that the operating system
used does not have any greater requirements itself

4)

With a large system it is essential that the system permits not only the
highest data point numbers but also a high dynamic response

1)

Dependent on the available storage space

2)

Dependent on the system configuration and the system load (due to the
event-oriented architecture, the system load is essentially determined by
the change rates of the values to be processed)

3)

By means of high-performance hardware configuration (one archiving
cluster and approx. 120 distributed systems that archive parallel values in
the cluster): 200,000 archived value changes per second

4)

Physical limit: <2048, in practice systems have already been implemented
with up to 550 distributed systems

5)

Physical limit: < 244 clients per server, recommended: max. 100 clients per
server

WinCC OA is ideally suited for use in very large distributed
systems. The optimum design of such systems demands corresponding system knowledge of WinCC OA. Due to the eventoriented processing, individual design parameters can be
increased or reduced as necessary in actual applications.

Siemens ST 80 / ST PC · 2013

4/151

© Siemens AG 2013

HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture

■ Ordering data

Order No.

SIMATIC WinCC
Open Architecture
system software V3.11
WinCC OA core components
WinCC OA Server
Language/script versions: De, En;
with license for:
WinCC OA single-user station
500 I/O V3.11
License for single-user station with
up to 500 I/Os of any type (bit, integer), alerting, extended trend, historical recording, not expandable to
more than one operator station, not
expandable by means of add-ons,
including S7 driver, OPC client,
OPC server, and OPC UA client.

4

WinCC OA Server I/O V3.11
License for server (without operator
station licenses), alerting, extended
trend, historical recording,
including S7 driver, OPC client,
OPC server, and OPC UA client.
• WinCC OA Server 1,000 I/O V3.11
with a max. of 1,000 I/Os of any
type
• WinCC OA Server 3,000 I/O V3.11
with a maximum of 3,000 I/Os of
any type
• WinCC OA Server 5,000 I/O V3.11
with a max. of 5,000 I/Os of any
type
• WinCC OA Server 10,000 I/O
V3.11
with a max. of 10,000 I/Os of any
type
• WinCC OA Server 15,000 I/O
V3.11
with a max. of 15,000 I/Os of any
type
• WinCC OA Server 25,000 I/O
V3.11
with a max. of 25,000 I/Os of any
type
• WinCC OA Server 50,000 I/O
V3.11
with a max. of 50,000 I/Os of any
type
• WinCC OA Server 75,000 I/O
V3.11
with a max. of 75,000 I/Os of any
type
• WinCC OA Server 100,000 I/O
V3.11
with a max. of 100,000 I/Os of any
type
• WinCC OA Server 150,000 I/O
V3.11
with a max. of 150,000 I/Os of any
type
• WinCC OA Server 200,000 I/O
V3.11
with a maximum of 200,000 I/Os of
any type
• WinCC OA Server 250,000 I/O
V3.11
with a maximum of 250,000 I/Os of
any type

4/152

Order No.
WinCC OA Server unlimited V3.11

6AV6351-1HA31-1AA0

6AV6351-1HB31-1AA0

6AV6351-1HC31-1AA0

6AV6351-1HD31-1AA0

License for server and one singleuser station (expandable to several
operator stations by means of clients) with unlimited number of I/O,
alerting, extended trend, historical
recording, including S7 driver,
OPC client, OPC server, and
OPC UA client.
WinCC OA Dongle V3.11
Hardware dongle on the USB port
for operation with a hardware-independent license attached to the
dongle, which can also extend the
hardware-linked license of the operator station or server on a temporary
basis.

6AV6351-1AH31-1AA0

WinCC OA on data medium
WinCC OA Software DVD – current
version on disk

6AV6351-1AX31-1AA0

WinCC OA Client floating
Language/script versions: De, En;
with license for:
WinCC OA Client V3.11
Additional operator station license
with all server operator station
functionalities.
The client license can be installed
on more than one PC – only the
number of simultaneously active
clients is counted.

6AV6351-1HE31-1AA0

WinCC OA Web User Interface
Language versions: De, En; with
license for:

6AV6351-1HF31-1AA0

WinCC OA Web Client V3.11
Web client license for WinCC OA
Server. Only the number of simultaneously active web clients is
counted.

6AV6351-1HG31-1AA0

6AV6351-1HH31-1AA0

6AV6351-1HJ31-1AA0

6AV6351-1HK31-1AA0

6AV6351-1HL31-1AA0

6AV6351-1HM31-1AA0

6AV6351-1HN31-1AA0

Siemens ST 80 / ST PC · 2013

6AV6351-1HP31-1AA0

6AV6351-1CP31-1AA0

6AV6351-1DP31-1AA0

© Siemens AG 2013

HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture

■ Ordering data

Order No.

WinCC OA Ultralight Client
WinCC OA Ultralight PC Client
Licenses for one or several ultralight
clients running on a laptop or PC.
Only the number of simultaneously
active ultralight clients is counted.
Please note restrictions of the ultralight client according to the online
help.
• WinCC OA 1 Ultralight PC Client
License for one ultralight client
• WinCC OA 3 Ultralight PC Clients
License for 3 ultralight clients
• WinCC OA 10 Ultralight
PC Clients
License for 10 ultralight clients
WinCC OA Ultralight Mobile Client
Licenses for one or several ultralight
clients running on a smartphone or
tablet PC. Only the number of simultaneously active ultralight clients is
counted. Please note restrictions of
the ultralight client according to the
online help.
• WinCC OA 1 Ultralight Mobile
Client
License for one ultralight client
• WinCC OA 3 Ultralight Mobile
Clients
License for 3 ultralight clients
• WinCC OA 10 Ultralight Mobile
Clients
License for 10 ultralight clients

6AV6351-1JA31-1AA0
6AV6351-1JB31-1AA0
6AV6351-1JC31-1AA0

6AV6351-1JG31-1AA0

Order No.
WinCC OA API interface
gen. V3.11
Application programming interface
for the integration of customer-specific managers or drivers. One
license is required for each development workstation. We strongly recommend the participation in a
Certified WinCC OA Developer
Workshop when ordering this
product for the first time.

6AV6351-1EK31-1AA0

WinCC OA Custom Driver V3.11
Extends a WinCC OA server license
with the option of communication
with a customer-specific driver. One
license is required for each customer-specific driver.

6AV6351-1EL31-1AA0

WinCC OA Custom Manager V3.11
Extends a WinCC OA server license
with the option of communicating
with a customer-specific manager.
One license is required for each
customer-specific manager

6AV6351-1EM31-1AA0

WinCC OA redundancy
6AV6351-1JG31-1AA0

6AV6351-1JH31-1AA0

WinCC OA Redundancy V3.11
Extends a WinCC OA Server with
the option of bumpless switchover
to a hot standby partner.

6AV6351-1FP31-1AA0

4

WinCC OA distributed systems
6AV6351-1JJ31-1AA0

WinCC OA parameter assignment
and development license
WinCC OA Para for single-user
station V3.11
Parameterization and development
license for single-user station,
graphic editor with symbol catalog
and ActiveX Controls, user-friendly
script development language, alerting, extended trend, historical
recording. Requires a corresponding single-user station license.

6AV6351-1EA31-1AA0

WinCC OA Para V3.11
Parameterization and development
license for server, graphic editor
with symbol catalog and ActiveX
Controls, user-friendly script development language, alerting,
extended trend, historical recording.
Requires corresponding server
license.

6AV6351-1EP31-1AA0

WinCC OA ETool V3.11
License for the use of the integrated
WinCC OA ETool engineering environment, including the object library
S7-BaseLib.
Intellectual property right owner:
Siemens AG.

6AV6351-1EJ31-1AA0

WinCC OA distributed systems
V3.11
Extends a WinCC OA Server to
include the Multiserver option.

6AV6351-1GP31-1AA0

WinCC OA Disaster Recovery
System
WinCC OA Disaster Recovery
Center V3.11
Allows the configuration of a remote
backup control center. A disaster
recovery center comprises two distributed systems. Each system can
be redundant or non-redundant.
Requires Oracle databases and
RDB. Refer to the online help for
example configurations. Each
server in the Disaster Recovery
System requires one WinCC OA
Disaster Recovery Center option.

6AV6352-1AA31-1AA0

Siemens ST 80 / ST PC · 2013

4/153

© Siemens AG 2013

HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture

■ Ordering data

Order No.

SIMATIC WinCC Open Architecture
V3.11 communication

4

Order No.
WinCC OA SINAUT 25 devices
SINAUT driver for connecting
up to 25 controllers

6AV6352-1BR31-1AA0

WinCC OA SINAUT 50 devices
SINAUT driver for connecting
up to 50 controllers

6AV6352-1BS31-1AA0

WinCC OA TLS driver
Driver in accordance with TLS regulations in connection with Siemens
Commbox (see separate data sheet).

6AV6352-1BA31-1AA0

WinCC OA Teleperm M
Driver for Teleperm M Bus C275
(requires an Acotex Comm Box)

6AV6352-1BB31-1AA0

WinCC OA SINAUT 250 devices
SINAUT driver for connecting
up to 250 controllers

6AV6352-1BT31-1AA0

WinCC OA S7 TCP/IP driver
TCP/IP for Siemens Industrial Ethernet

6AV6352-1BC31-1AA0

WinCC OA SINAUT unlimited
SINAUT driver – unlimited license

6AV6352-1BU31-1AA0

WinCC OA Modbus TCP/IP driver
TCP/IP for Schneider Modbus

6AV6352-1BD31-1AA0

6AV6352-1CA31-1AA0

WinCC OA Modbus serial
Serial driver for Schneider Modbus

6AV6352-1BE31-1AA0

WinCC OA RK512
Driver for connection
via 3964R / RK512 protocol

6AV6352-1CB31-1AA0

WinCC OA SSI driver
Driver for SAT telecontrol components

6AV6352-1BF31-1AA0

WinCC OA PROFIBUS DP
Driver PROFIBUS DP,
an Applicom card is required

6AV6352-1CC31-1AA0

WinCC OA SNMP
Driver SNMP – network monitoring
(V2&V3)

6AV6352-1BG31-1AA0

WinCC OA PROFIBUS S7
Driver PROFIBUS S7 + MPI,
an Applicom card is required

6AV6352-1BH31-1AA0

WinCC OA Omron FINS TCP-IP
Driver Omron FINSTCP-IP,
an Applicom card is required

6AV6352-1CE31-1AA0

WinCC OA IEC 104
Driver IEC 60870-5-104

6AV6352-1BJ31-1AA0

WinCC OA GE Fanuc SRTP
Driver GE Fanuc SRTP,
an Applicom card is required

6AV6352-1CF31-1AA0

WinCC OA IEC 101
Driver IEC 60870-5-101
WinCC OA DNP3 10 devices
Driver DNP3 for connecting
up to 10 DNP3 devices

6AV6352-1BK31-1AA0

WinCC OA Allen Bradley Ethernet/IP
Driver Allen Bradley Ethernet/IP,
an Applicom card is required.

6AV6352-1CG31-1AA0

WinCC OA DNP3 25 devices
Driver DNP3 for connecting
up to 25 DNP3 devices

6AV6352-1BL31-1AA0

6AV6352-1CH31-1AA0

WinCC OA DNP3 50 devices
Driver DNP3 for connecting
up to 50 DNP3 devices

6AV6352-1BM31-1AA0

WinCC OA Cerberus
Driver for connection with the Siemens
DMS7000 / Cerberus fire alarm system. Communication is implemented
via the C-Bus (Cer-Ban) using the
serial interface RS 232 (MK 7022).

6AV6352-1BN31-1AA0

WinCC OA OPC UA Server
Driver for OPC UA DA and
OPC UA AC Server

6AV6352-1CJ31-1AA0

WinCC OA DNP3 250 devices
Driver DNP3 for connecting
up to 250 DNP3 devices
WinCC OA DNP3 unlimited
Driver DNP3 – unlimited license

6AV6352-1BP31-1AA0

WinCC OA SINAUT 10 devices
SINAUT driver for connecting
up to 10 controllers

6AV6352-1BQ31-1AA0

■ More information
Further information can be found in the Internet at:
http://www.siemens.com/wincc-open-architecture

4/154

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture Add-ons

■ Overview
SIMATIC WinCC Open Architecture is a SCADA system for
visualizing and operating processes, production flows,
machines and plants in all industrial sectors.
SIMATIC WinCC OA is built consistently on object-oriented
structures. The rigorous and well-considered use of objectoriented structures, from process images to the database, help
to improve engineering costs for SIMATIC WinCC OA customers.
Distributed systems enable the connection of up to 2048 autonomous SIMATIC WinCC Open Architecture systems via one
network. Each subsystem can be configured either as singleuser or multi-user system, each of which may be redundant or
non-redundant.

• Current version: SIMATIC WinCC Open Architecture V3.11
Runs on:
- Windows 8 Enterprise (64-bit)
- Windows 7 Ultimate/Enterprise/Professional SP1 (32/64-bit)
- Windows XP SP2/SP3 (32-bit)
- Windows Server 2008 R2 (64-bit)
- Red Hat Linux 5 (32/64-bit)
- OpenSuse 12.1 (32/64-bit)
- Sun Solaris 10 SPARC (32-bit)
- Sun Solaris 10 x86 (64-bit)
- VMWare ESXi Version 4.0.0 & 5.0.0
Note:
Native 64-bit support on 64-bit systems.

■ Function
SIMATIC WinCC Open Architecture add-ons
The universal WinCC Open Architecture basic software is the
basis for modular expansions. These functional expansions are
available in the form of WinCC Open Architecture add-ons.

Field devices
or other connected systems

4

MODBUS (TCP)

WinCC OA
Server (multi-user system)
OPC UA (TCP)
WinCC OA
Server
(stand alone
system)
Operational station

System 3

Operational station

System 2

WinCC OA System communication TCP

System 1

WinCC OA
Server
(redundant)

Operational station

Operational station

Operational station

G_ST80_XX_00480

S7 Industrial Ethernet (TCP)

Distributed systems with WinCC OA

Siemens ST 80 / ST PC · 2013

4/155

© Siemens AG 2013

HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture Add-ons

■ Function (continued)

4

Add-ons

Task

Add-ons

Task

ETool

The engineering tool ETool offers significant
benefits in engineering in the case of combined
WinCC OA and SIMATIC STEP7/PCS7 projects. It
provides a user-friendly engineering environment
that permits easy, integrated and fast configuration
on the basis of the WinCC OA mass parameterization.

Video
(see figure below)

Enables the integration of a video management
system in WinCC OA. Through the combination of
SCADA and video monitoring in one system, the
costs for separate video interfaces and the additional expense of maintenance and operation can
be saved, and the period of training for operating
personnel can also be reduced.

BACnet

BACnet provides an integrated BACnet-compliant
online/offline engineering solution for building
automation technology, including object library.
Designed for heating, ventilation and air-conditioning, lighting control and safety systems.

HTTP server

For displaying WinCC OA data via Intranet and
Web.

Authentication
via Kerberos

A WinCC OA system can be exposed to a variety
of attacks. An unauthorized WinCC OA System
could set up a connection to the distribution manager or hackers could try to manipulate WinCC OA
messages. Secure authentication has been developed to prevent such attacks. The authentication
based on Kerberos enables each WinCC OA component to verify the identity of another component.
WinCC OA servers can verify the identity of the clients and clients can verify the identity of the servers. In addition, Kerberos ensures that messages
are not modified during their transmission (capture-replay attacks are prevented). Furthermore,
it is also possible to send messages in encrypted
form.

AMS (Advanced
Maintenance Suite)

For the effective planning, administration, implementation and monitoring of maintenance work
and faults. The processes are evaluated by means
of statistics and reports are communicated.

Web client

From a technical standpoint, the WinCC OA Web
Client is a plug-in that is downloaded via the web
browser (which is used on the client computer)
and a WinCC OA UI Manager is then displayed
embedded in the HTML page. No WinCC OA
installation on the client computer is required,
except for the required web client plug-ins.

Ultralight client

A "thin client" that supports access to the plant via
a mobile device (such as a cell phone or tablet) in
addition to a PC workstation. Access is possible
via a standard Web browser using native Web
technologies (Javascript, SVG) without the need
for any additional installations. It provides a user
interface even at those locations with Internet connections offering very low bandwidth, as only the
most essential data is transferred.

Disaster Recovery
System
(see figure below)

This system expands the simple redundancy to
include a second redundant system, to which the
system can switch over in the event of a fault
(e.g. fire or explosion in the building of the primary
system). By means of this additional local redundancy, the highest level of system stability is
obtained.

S7 AdvancedLib
object library

The S7 AdvancedLib (AdvS7) is an industry-independent object library that permits the use and
visualization of objects from the process control
system (e.g.: drives, valves, regulators, motors,
etc.) in a project with WinCC OA and S7. In addition to the WinCC OA and AdvS7 license, the use
of S7 AdvancedLib requires the use of the relevant
library on the SIMATIC side.

Maintenance package

Includes the following functions: Operating hours
counter, operating cycle counter and maintenance
log.

Scheduler

Permits the creation, parameterization and management of time programs that allow the time and
event-driven triggering of specific actions.

Recipes

WinCC OA recipes allow setpoints or commands
for certain data point elements to be sent simultaneously. Based on "recipe types", which define the
quantity of the assigned data point elements, recipes are created that send their values to the data
point elements upon activation.
With the help of this viewer, standardized cards of
a geo-information system (GIS) can be fully integrated in WinCC OA. Furthermore, it is possible to
display all WinCC OA objects in the cards.

GIS Viewer

Powerful report generator directly in Microsoft
Excel. Templates can be created easily and
directly in Excel. If a report has to be created over
a defined period of time, the system accesses the
template and automatically completes it with data
from the WinCC OA process database. Reports
can also be created, printed and saved on a timecontrolled basis, without any need for user access.
The Excel Report fully supports compression
structures (AC - archive compression) of
WinCC OA.

Excel report

Communication
Center

4/156

Stands for modern alarm management/remote
alerting and communication using the latest standards and various media. The Communication
Center creates synergies by using the various
interfaces for remote alerting via the control
system.
Text message and email media are covered with
the Communication Center.

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture Add-ons

■ Function (continued)
Video workstation
Monitor 1
Operator keyboard
mouse
joystick

Video monitor 1

Video monitor 2
(optional)

Control monitor
(optional)

Encoder
Control commands

TCP/IP
connection
Decoder

Cameras or
crossbars

Network
video recorder

WinCC OA
Server
Control of monitor wall via POSA protocol

Monitor wall
(monitors 2 ... n)

G_ST80_XX_00481

4

Network topology Video

Primary Server System (PSS)

Secondary Server System (SSS)

Database in
Oracle Cluster

WinCC OA
active
Server (A)

WinCC OA
Hot-Standby
System

WinCC OA
passive
Server (B)

Operating Interface
with one or two
interfaces

WinCC OA
active
Server (C)

WinCC OA
Hot-Standby
System

WinCC OA
passive
Server (D)

Field device or other
connected systems like
for example OPC UA

G_ST80_XX_00482

Database in
Oracle Cluster

Disaster Recovery System architecture with WinCC OA
Siemens ST 80 / ST PC · 2013

4/157

© Siemens AG 2013

HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture Add-ons

■ Ordering data

Order No.

SIMATIC WinCC
Open Architecture add-ons

4

Order No.
Solution Frameworks
WinCC OA PMS
Application framework for the implementation of production management
systems. The framework offers
functions for recording and evaluating
production and batch-related quality
data. This item is not available as a
product but only in combination with
consulting and additional testing
overhead.

6AV6352-1EA31-1AA0

WinCC OA topology package
The topology package is an application framework enabling the topological coloring of network views.
A qualitative statement is made
regarding which parts of a network are
directly connected to which infeed
units in a connection established by
switching elements. Only available in
combination with consulting and additional testing overhead.

6AV6352-1EB31-1AA0

WinCC OA ACAS
WinCC OA Advanced Command
Authority Suite framework for managing and visualizing authority settings.
The license includes the management
panel and panel expansions for alarm,
horn and acknowledgement functions. This item is not available as a
product but only in combination with
consulting and additional testing overhead.

6AV6352-1EC31-1AA0

WinCC OA BACnet driver +
diagnostics
Extends a WinCC OA Server to include
a license for using the WinCC OA
BACnet online engineering environment consisting of WinCC OA BACnet
driver, WinCC OA BACnet object
library including faceplates, and
WinCC OA BACnet browser
(max. 5,000 objects per server).

6AV6352-1DA31-1AA0

WinCC OA BACnet Engineering
Extends a WinCC OA Server to include
a license for using the WinCC OA
BACnet engineering environment consisting of WinCC OA BACnet browser,
WinCC OA EDE-Tool + EDE file interface (requires the WinCC OA engineering license) (max. 5,000 objects
per server).

6AV6352-1DB31-1AA0

WinCC OA GIS
GIS viewer for displaying ESRI Shapes
Files. One license is required for each
UI. Can be used in WinCC OA Client
and Web Client. Maps are not
included. Dynamization performed
using Ctrl scripting.

6AV6352-1DC31-1AA0

WinCC OA S7 AdvancedLib
Runtime license for using the object
library WinCC OA S7 AdvancedLib,
coordinated with the SIMATIC object
library also supplied, which is free of
charge until revoked. License required
for each server.

6AV6352-1DD31-1AA0

6AV6352-1DE31-1AA0

WinCC OA Report 1 UI
Expands a WinCC OA Server
by 1 active Excel report process;
Microsoft Excel is not included.

6AV6352-1FA31-1AA0

WinCC OA Maintenance
Maintenance management for recording operating hours, switching cycles,
alarm handling and notepad function.
License required for each server.

6AV6352-1FB31-1AA0

WinCC OA Scheduler
Daily, weekly and monthly program, as
well as individual non-periodic events
with consideration of public holidays,
assignment of priority and override
function. License required for each
server.

6AV6352-1DF31-1AA0

WinCC OA Report 2 UI
Expands a WinCC OA Server
by 2 parallel active Excel report
processes; Microsoft Excel is not
included.

6AV6352-1FC31-1AA0

WinCC OA Recipe
Creation of any recipe types and recipes, acceptance of current process
values as recipe, activation/download
to data points, import and export
(Microsoft Excel). License required for
each server.

6AV6352-1DG31-1AA0

WinCC OA Report 5 UI
Expands a WinCC OA Server
by 5 parallel active Excel report
processes; Microsoft Excel is not
included.
WinCC OA Report 10 UI
Expands a WinCC OA Server
by 10 parallel active Excel report
processes; Microsoft Excel is not
included.

6AV6352-1FD31-1AA0

WinCC OA RDB
RDB Oracle connection for WinCC OA
Server S-UL. Oracle licenses are not
included. License required for each
server.

6AV6352-1DH31-1AA0

4/158

Excel report

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture Add-ons

■ Ordering data

Order No.

Communication Center
WinCC OA CommCenter 1
Basic package for 25 alarms. Output
as text message or e-mail is possible.
Price per WinCC OA Server.

6AV6352-1GA31-1AA0

WinCC OA CommCenter 2
Basic package for 250 alarms. Output
as text message or e-mail is possible.
Price per WinCC OA Server.

6AV6352-1GB31-1AA0

WinCC OA CommCenter 3
Basic package for 2,500 alarms. Output as text message or e-mail is possible. Price per WinCC OA Server.

6AV6352-1GC31-1AA0

WinCC OA CommCenter 4
Basic package for unlimited alarms.
Output as text message or e-mail is
possible. Price per WinCC OA Server.

6AV6352-1GD31-1AA0

Video management

Order No.
WinCC OA video driver RS 485TVI
Driver for controlling TVI pan-tilt
cameras. One license is required for
each WinCC OA Server.

6AV6352-1HK31-1AA0

WinCC OA video driver SNK
RS485 Funkwerk
Driver for controlling Funkwerk pan-tilt
cameras. One license is required for
each WinCC OA Server.

6AV6352-1HL31-1AA0

WinCC OA video driver SNK
RS485 Globe
Driver for controlling Globe pan-tilt
cameras.
One license is required for each
WinCC OA Server.

6AV6352-1HM31-1AA0

WinCC OA video driver SNK
development
Driver development for controlling
pan-tilt cameras

6AV6352-1HN31-1AA0

WinCC OA video driver
for cameras with RCP+ and H264
Drivers for controlling cameras with
RCP+ and H264.
One license is required for each
WinCC OA Server.

6AV6352-1HP31-1AA0

WinCC OA video driver dev.
Driver development for controlling
decoder/encoder/host protocols

6AV6352-1HQ31-1AA0

WinCC OA video driver Bosch
IntKey
Driver for controlling Bosch IntKey
console controller.
One license is required per server

6AV6352-1HR31-1AA0

WinCC OA Video driver development for console controllers
Driver development for controlling
console controllers

6AV6352-1HS31-1AA0

6AV6352-1HT31-1AA0

6AV6352-1HU31-1AA0

WinCC OA Video Light
Including 4 streams. Possible video
operator station configuration:
1 x quad image or 2 dual images or
4 single images. Not expandable with
further streams, redundancy not possible.

6AV6352-1HA31-1AA0

WinCC OA Video Basic
Including 7 streams. Possible video
operator station configuration: Display
in quad, dual or single images.
Expandable by additional streams,
redundancy is possible. One license is
required for each WinCC OA Server.

6AV6352-1HB31-1AA0

WinCC OA Video Extension
5 Streams
Extends WinCC OA Video Basic
by 5 streams

6AV6352-1HC31-1AA0

WinCC OA Video Extension
7 Streams
Extends WinCC OA Video Basic
by 7 streams

6AV6352-1HD31-1AA0

WinCC OA Video Extension
32 Streams
Extends WinCC OA Video Basic
by 32 streams

6AV6352-1HE31-1AA0

WinCC OA video driver Bosch VRM
(NVR)
Drivers for controlling Bosch video
recording equipment / NVR.
One license is required per server

WinCC OA Video Extension
128 Streams
Extends WinCC OA Video Basic by
128 streams

6AV6352-1HF31-1AA0

WinCC OA video driver development for recording equipment / NVR
Driver development for video recorder
equipment / NVR

WinCC OA Video Extension
256 Streams
Extends WinCC OA Video Basic
by 256 streams

6AV6352-1HG31-1AA0

WinCC OA Video Extension
512 Streams
Extends WinCC OA Video Basic
by 512 streams

6AV6352-1HH31-1AA0

WinCC OA video driver SNK
RS485 eneo
Driver for controlling eneo pan-tilt
cameras. One license is required for
each WinCC OA Server.

6AV6352-1HJ31-1AA0

4

HTTP server
WinCC OA HTTP Server
Forwarding of alarms, events and
WinCC OA information to the Internet
in HTML format including 1 HTTP connection.

6AV6352-1KA31-1AA0

WinCC OA HTTP Server Extension5
Extends the WinCC OA HTTP server
by 5 HTTP connections.

6AV6352-1KB31-1AA0

WinCC OA HTTP Server
Extension10
Extends the WinCC OA HTTP server
by 10 HTTP connections.

6AV6352-1KC31-1AA0

WinCC OA HTTP Server
Extension25
Extends the WinCC OA HTTP server
by 25 HTTP connections.

6AV6352-1KD31-1AA0

Siemens ST 80 / ST PC · 2013

4/159

© Siemens AG 2013

HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture Add-ons

■ Ordering data

Order No.

Kerberos
WinCC OA Secure
Extends a WinCC OA Server to include
protection by Kerberos.
Each WinCC OA Server requires a
separate WinCC OA Secure license.

6AV6352-1LA31-1AA0

AMS (Advanced Maintenance Suite)

4

AMS Starter Package 20A/E
This fully functional trial license
valid for 90 days includes the
AMS application as well as up to
20 A/E = 20 checklists assigned to
alarm/event DP. 1)2)3)

6AV6352-1MA31-1AA0

AMS Entry 20 A/E
The license includes the
AMS application as well as up to
20 A/E = 20 checklists assigned to
alarm/event DP. 1)2)3)

6AV6352-1MB31-1AA0

AMS Small 100 A/E
The license includes the
AMS application as well as
up to 100 A/E = 100 checklists
assigned to alarm/event DP. 1)2)3)

6AV6352-1MC31-1AA0

AMS Medium 1,000 A/E
The license includes the
AMS application as well as
up to 1,000 A/E = 1,000 checklists
assigned to alarm/event DP. 1)2)3)

6AV6352-1MD31-1AA0

AMS Large 5,000 A/E
The license includes the
AMS application as well as
up to 5,000 A/E = 5,000 checklists
assigned to alarm/event DP. 1)2)3)

6AV6352-1ME31-1AA0

■ More information
Additional information is available on the Internet at:
http://www.siemens.com/wincc-open-architecture

4/160

Siemens ST 80 / ST PC · 2013

Order No.
AMS Upgrade Large
The license contains an upgrade of
the AMS Large 5,000 A/E license with
1,000 A/E = 1,000 checklists assigned
to alarm/event DP.

6AV6352-1MF31-1AA0

AMS UL A/E
The license includes the AMS application as well as an unlimited number of
alarm/event DP checklist
assignments. 1)2)3)

6AV6352-1MG31-1AA0

AMS Client 2 UI
Operating station license for simultaneous use of no more than 2 parallel
client sessions. The client license can
be installed on more than one PC –
only the number of simultaneously
active clients is counted.

6AV6352-1MH31-1AA0

AMS Client 5 UI
Operating station license for simultaneous use of no more than 5 parallel
client sessions. The client license can
be installed on more than one PC –
only the number of simultaneously
active clients is counted.

6AV6352-1MJ31-1AA0

AMS Client 10 UI
Operating station license for simultaneous use of no more than 10 parallel
client sessions. The client license can
be installed on more than one PC –
only the number of simultaneously
active clients is counted.

6AV6352-1MK31-1AA0

1)

The basic price also includes the AMS Reports packages.

2)

AMS importer as well as 1 day of consulting for initial design by
ETM Consultants (excluding travel expenses) and 5 hours of telephone
support within 3 months after delivery.

3)

AMS Reports and AMS Importer, and 1 day of consulting for initial conceptualization by ETM consultants (not incl. travel costs). This license does not
include any support and cannot be expanded or extended.

© Siemens AG 2013

HMI Software
SIMATIC ProAgent process diagnostics software
SIMATIC ProAgent

■ Overview

■ Benefits

• Process error diagnostics software for quick and precise
diagnosis of faults/errors in plants and machines for
SIMATIC S7 and SIMATIC HMI
• Standardized diagnostics concept for various
SIMATIC components:
optimum interaction of STEP 7 engineering tools and
SIMATIC HMI
• Standardized user interface

• Integral component of Totally Integrated Automation (TIA):
increases productivity, minimizes the engineering outlay,
reduces the lifecycle costs
• ProAgent:
- Provides optimum support for plant and machine personnel
in respect of troubleshooting and fault rectification
- Increases plant availability
- Reduces downtimes
• No further configuration overhead for diagnostics functionality
• Frees up PLC capacity with regard to memory and program
execution time
• No special operator know-how is required thanks to clearly
comprehensible indication of the cause of error

■ Application
Increased productivity is being achieved more and more by
cutting costs.
In this context, the focus is increasingly on maintenance.
The emphasis here is on rectifying faults as quickly and
efficiently as possible.

G_ST80_XX_00367

67(3

Process error diagnostics with ProAgent for WinCC flexible /ProAgent
and with the STEP 7 engineering tools

Ideally, the operating personnel should also perform part of the
maintenance tasks. The operating personnel are on-site, they
are familiar with the procedures and can intervene quickly. This
saves time and reduces costs. It is precisely here that ProAgent
can assist operating personnel in identifying faults quickly, in
particular in the automotive and machine tool industries.
In the event of a process fault, process fault diagnostics with
SIMATIC ProAgent will provide information about the location
and cause of that fault and support personnel with troubleshooting.
The ProAgent solution has been optimized specifically for use
with SIMATIC S7-300/S7-400 and SIMATIC WinAC.
It can be used in combination with the S7-PDIAG, S7-GRAPH
and S7-HiGraph1) STEP 7 engineering tools. The ProAgent
option package features standard displays that are updated with
process-specific data during runtime.
1)

Process diagnostics with S7-HiGraph in combination with
TP/OP/MP 270/277, MP 370/377, and C7636 and PC RT systems.

3B67B;;B

67(3

Process error diagnostics with WinCC/ProAgent and the STEP 7
engineering tools

Siemens ST 80 / ST PC · 2013

4/161

4

© Siemens AG 2013

HMI Software
SIMATIC ProAgent process diagnostics software
SIMATIC ProAgent

■ Function
• Context-sensitive diagnostics initiation due to process error
message
• Output of operands with symbols and comment
• Switching is possible between LAD, STL and signal list
• Supporting fault rectification with direct process access when
using the motion display
• Output of the faulty operands directly in the message
including address, symbol and comment 1)
• Consistency test in RT:
Inconsistent diagnostic units are marked with icons. This
permits quick locating of faults regarding configured data in
the commissioning phase.
• Direct, unit-related entry point in the diagnostic display from
user displays by using ProAgent functions
• Unit or message-related entry to STEP 7 (LAD/STL/FD editor,
S7-GRAPH, HW CONFIG (upon system error messages)),
supported fully automatically 2)
• Unit or message-related entry to STEP 7),
supported fully automatically 3)
• Graphic display of step sequences (overview display) 4)

4

1)

In combination with TP/OP/MP 270/277, MP 370/377, C7 636,
WinCC/ProAgent as of V6.0, and WinCC flexible /ProAgent

2)

WinCC/ProAgent as of V5.5 and as of WinCC flexible 2007 /ProAgent
on PC RT

3)

Only WinCC/ProAgent as of V5.5

4)

As of WinCC flexible 2007 /ProAgent, WinCC/ProAgent as of V5.6 in
combination with S7-GRAPH as of V5.1 (OCX is delivered as of
S7-GRAPH 5.1)

Standardized user interface with standard displays
• Message display
• Unit overview
• Diagnostics detail display
• Motion display
• Sequencer operating display
The displayed image contents are related to the previously
selected units or messages. This means that the proper. contextsensitive diagnostics display can be called up based on a
message or a selected technological unit.

4/162

Siemens ST 80 / ST PC · 2013

Message display
All of the existing process messages are shown in the message
display. Context-sensitive branching to other diagnostic
displays is also possible with a selected message. The
operating personnel can also take the message directly from the
erroneous operands and react immediately without having to
perform any other operations on the HMI device. WinCC flexible
permits this function on the Windows CE-based devices
TP/OP/MP 270/277, MP 370/377, and on PC Runtime systems.
The function is available as of version 6.0 for WinCC/ProAgent.

Unit overview
The units overview displays all technological units and the
respective sub-units (system/machine components) in table
form. In this display, the user is able to recognize, for example,
which operating mode or which status the respective unit is in.
The operating mode can be changed by the user if required.
Faulty units are marked with attributes.

© Siemens AG 2013

HMI Software
SIMATIC ProAgent process diagnostics software
SIMATIC ProAgent

■ Function (continued)
Diagnostics detail display

Sequencer operating display

The diagnostic detail display shows the faulty operands at the
time of origination of a process error. As an option, current status
information can also be displayed. The diagnostics results are
either displayed in a ladder diagram (LAD), statement list (STL),
or in a clearly arranged signal list overview. The output of the
operands depends on the display format with symbols and
comments from the S7 symbol table. Only the operands that
cause the fault are displayed and marked with a highlighted
attribute. Switching to a display that calls up the current status of
all operands in the controller is also possible.

The sequencer operating display supports sequencer control.
This makes functions such as initializing and acknowledging
sequencers, activating/deactivating individual steps and
operating mode settings possible analog to the status/control in
S7-GRAPH.
The steps are output to a list with step number/name. Attributes
for identifying an active/faulty step give the operating personnel
an overview of the current status of the step sequence.

4

Motion display

Sequencer diagnostic display

The motion display is used for supported fault rectification. Every
motion line contains a comment line that describes the motion
(e.g. x-axis), two actions for implementing the motion, response
concerning the actuation of a motion and information on the
respectively achieved end positions (max. 16).

WinCC flexible/ProAgent and WinCC/ProAgent1) also offer
capabilities for graphic monitoring and sequencer diagnostics.
This gives the user the ability to monitor active/faulty steps as
well as the fault cause, e.g. faulty transition conditions, simultaneously on the HMI device.

The motion itself is controlled with softkeys on the side of
SIMATIC Panels and Multi Panels. For time-critical motions, the
actuation can be done directly through inputs of the controller
(depending on the capabilities of the target hardware:
24 V direct keys, DP direct keys via PROFIBUS).

1)

WinCC/ProAgent as of V5.6 in combination with S7-GRAPH as of V5.1
(OCX is delivered as of S7-GRAPH 5.1)

Siemens ST 80 / ST PC · 2013

4/163

© Siemens AG 2013

HMI Software
SIMATIC ProAgent process diagnostics software
SIMATIC ProAgent

■ Technical specifications
Interfaces
• Can be used in conjunction with
programmable controllers:
• Types of connection

WinCC/ProAgent

WinCC flexible /ProAgent

SIMATIC S7:
S7-300/S7-400; WinAC
SIMATIC S7 Protocol Suite:
MPI, PROFIBUS DP, Industrial Ethernet, TCP/IP

SIMATIC S7:
S7-300/S7-400; WinAC
SIMATIC S7 Protocol Suite:
MPI, PROFIBUS DP,
PROFINET IO, Industrial Ethernet, TCP/IP

Display units
Standard images for:

Standard displays for easy embedding in user displays,
example project for MP 377
3 (de/en/fr)

5 (de/en/fr/it/es)

Modification of HMI diagnostics data
management in RT

WinCC/ProAgent V6.0 and higher

No

Unit overview

Yes

Yes

Message display

Yes

Yes

Sequencer operating display

Yes

Yes

Diagnostics detail display
• Display
STL/LAD/signal list
• Display of operands with symbol and
comment

Yes
Yes/Yes/Yes

Yes
Yes/Yes/Yes

Yes

Yes

Criteria analysis

When fault occurs/current status/can be archived

When fault occurs/current status

6

6

2
16

2
16

de/en/fr; included in scope of delivery

de/en/fr/it/es; included in scope of delivery

HMI software

WinCC V7.0 SP3
(ProAgent V7.0 SP3)

WinCC flexible 2008

Operating system:
Configuration

WinCC/ProAgent V7.0 + SP2:
Windows Professional SP3, Windows 7 (32 bit) Ultimate,
Business, and Enterprise

WinCC flexible /ProAgent 2008 + SP2:
Windows XP SP3,
Windows 7 Professional,
Ultimate, Enterprise

Operating system
Runtime

WinCC/ProAgent V7.0 + SP2:
Windows XP Professional SP3,
Windows 7 (32 bit) Ultimate, Business and Enterprise,
Windows 2003 Server SP2, Windows 2008 Server SP2

WinCC flexible /ProAgent for SIMATIC Panels:
WinCC flexible /ProAgent for WinCC flexible Runtime:
Windows XP SP3,
Windows 7 Professional, Ultimate, Enterprise

STEP 7
• S7-GRAPH
• S7-PDIAG
• S7-HiGraph

V5.4 SP4 and higher
V5.3 SP6 and higher
V5.3 SP3 and higher
No

V5.3 and higher
V5.2 + SP3 and higher
V5.1 and higher
V5.3 and higher

Type of delivery
(one license is required for each target
hardware)

CD-ROM / Runtime license

Runtime license

Number of languages for
online language selection
Functionality

4

Motion display
• Number of viewable
movements
• Directions of motion
• Number of viewable
end positions per movement
Documentation
In electronic format
Requirements

4/164

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

HMI Software
SIMATIC ProAgent process diagnostics software
SIMATIC ProAgent

■ Ordering data

Order No.

SIMATIC WinCC/ProAgent

Order No.
Documentation
(must be ordered separately)

Software option package for
process error diagnostics based
on S7 GRAPH V5 and higher and
S7 PDIAG V5 and higher;
functional enhancement for
SIMATIC WinCC;
electronic documentation in English,
French and German;
functions and standard screens for
use on a PC (resolution 1024 x 768
pixel) and Panel PC 577/677/
877 15" (resolution 1024 x 768 pixel)
in English, French and German,
Runtime license (single license)
WinCC version:

SIMATIC HMI Manual Collection

6AV6691-1SA01-0AX0

Electronic documentation
on CD-ROM
5 languages (English, German,
French, Italian and Spanish);
contains: all currently available
user manuals, device manuals
and communication manuals for
SIMATIC HMI

• V7.0 SP3; for WinCC V7.0 SP3 1)

6AV6371-1DG07-0AX0

Upgrade
• to V7.0 SP3 1)

6AV6371-1DG07-0AX4

SIMATIC WinCC flexible /ProAgent
Software option package for process error diagnostics based on
S7 PDIAG V5.1 and higher,
S7 GRAPH V5.2 + SP3 and higher;
S7 HiGRAPH V5.3 and higher.
Functional enhancement for
SIMATIC WinCC flexible; electronic
documentation in English, French,
German, Italian and Spanish
• WinCC flexible /ProAgent
for SIMATIC Panels
Runtime license (Single License)
executable on TP/OP/MP 270/277,
Mobile Panel 277 and MP 370/377
• WinCC flexible /ProAgent
for WinCC flexible Runtime
Runtime license (single license)

4

6AV6618-7DB01-3AB0

6AV6618-7DD01-3AB0

1)

Not multi-station-capable

Siemens ST 80 / ST PC · 2013

4/165

© Siemens AG 2013

HMI Software
Notes

4

4/166

Siemens ST 80 / ST PC · 2013

5

© Siemens AG 2013

PC-based Automation
5/2

SIMATIC Industrial PC

5/3
5/7
5/13
5/20

Rack PC
SIMATIC IPC547D
SIMATIC IPC647C
SIMATIC IPC847C

5/27
5/30
5/36
5/39
5/44
5/47

Box PC
SIMATIC IPC227D
SIMATIC IPC427D
SIMATIC IPC427C
SIMATIC IPC627C
SIMATIC IPC827C

5/50
5/53
5/58
5/63
5/67
5/71

SIMATIC Panel PC
SIMATIC IPC277D
SIMATIC IPC477D
SIMATIC HMI IPC477C
SIMATIC HMI IPC577C
SIMATIC HMI IPC677C

5/76
5/77
5/84
5/90

5/167
5/167
5/168
5/168
5/169
5/169

Input and output devices
SIMATIC PC keyboard
IP65 membrane keyboard, desk version
IP65 membrane keyboard,
19" built-in version
19" slide-in keyboard PS/2 with trackball
SIMATIC IPC mouse

5/170
5/171
5/171
5/172
5/172
5/173

SITOP power supplies
1-phase, 24 V DC/10 A (SITOP PSU100S)
1-phase, 24 V DC/20 A (SITOP PSU100S)
3-phase, 24 V DC/10 A (SITOP PSU300S)
3-phase, 24 V DC/20 A (SITOP PSU300S)
3-phase, 24 V DC/40 A (SITOP PSU300S)

5/174

24 V DC uninterruptible power supplies

5/176
5/177
5/178

DC UPS with capacitors
SITOP UPS500S
SITOP UPS500P

SIMATIC PC-based controllers
SIMATIC WinAC RTX
SIMATIC WinAC RTX F
SIMATIC WinAC ODK

5/179
5/181

5/91
5/93
5/100

Embedded Controller
EC31
Expansion modules

5/183

5/101
5/102
5/103
5/104
5/108
5/109
5/110
5/114

Embedded bundles/Software packages
SIMATIC IPC227D bundles
SIMATIC IPC427D bundles
SIMATIC IPC427C bundles
SIMATIC IPC277D bundles
SIMATIC IPC477D bundles
SIMATIC HMI IPC477C bundles
Software packages for SIMATIC IPC
and S7-mEC

DC UPS with battery modules
DC UPS module 6 A,
DC UPS module 15 A
DC UPS module 40 A,
Battery module 1.2 Ah
Battery module 2.5 Ah,
Battery module 3.2 Ah
Battery module 7 Ah,
Battery module 12 Ah

5/117
5/117
5/120
5/130
5/134
5/136
5/139
5/143

Industrial monitors and thin clients
SIMATIC Industrial Flat Panel MT
SIMATIC Industrial Flat Panel
SIMATIC Flat Panels
SCD desk monitors SCD 19101
SCD monitors 1900
SIMATIC Industrial Thin Client
SIMATIC Thin Client

5/146
5/147
5/149
5/150
5/151
5/152

RMOS3 real-time operating system
RMOS3 V3.50 real-time operating system
RMOS3-GNU V3.0
RMOS3-TCP/IP V3.0
RMOS3-GRAPHX V1.0
BSP SIMATIC IPC V4.0 for RMOS3

5/153
5/155
5/155
5/156
5/161
5/163
5/164
5/165
5/166

Expansion components / accessories
SIMATIC IPC CompactFlash
SIMATIC IPC (Service) USB FlashDrive
PC I/O
SIMATIC Panel PC Remote Kit
SIMATIC IPC Image & Partition Creator
SIMATIC IPC DiagMonitor
SIMATIC IPC Remote Manager
SIMATIC IPC BIOS Manager

5/182

5/184
5/185

MASTERGUARD power supply

5/186
5/186
5/187
5/188
5/189
5/191
5/192
5/193
5/194
5/196
5/198
5/199
5/201
5/203
5/205
5/206
5/207

Communication – Industrial Ethernet
Connection options to SIMATIC IPCs
CP 1604
CP 1616
CP 1612 A2
CP 1613 A2
CP 1623
CP 1628
HARDNET-IE S7-REDCONNECT
SOFTNET for Industrial Ethernet
SOFTNET-IE RNA
SOFTNET PN IO
OPC server for Industrial Ethernet
PN CBA OPC server
S7 OPC Redundancy
for Industrial Ethernet
SNMP OPC server
SINEMA server

5/208
5/208
5/209
5/211
5/213
5/215
5/217
5/219
5/221
5/223
5/225
5/227
5/229
5/230

Communication – PROFIBUS
Connection options to SIMATIC IPCs
CP 5603
CP 5613 A2
CP 5614 A2
CP 5623
CP 5624
CP 5512
CP 5612
CP 5622
CP 5711
SOFTNET for PROFIBUS
OPC server for PROFIBUS
S7 OPC Redundancy for PROFIBUS

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
SIMATIC Industrial PC
Industrial PC

■ Overview

Industrial PC
Our reliable and innovative industrial PCs are the optimal
PC hardware platform for PC-based Automation from Siemens.
Rack PC
Rack PCs are flexible, high-availability industrial PC systems for
powerful yet compact applications using 19" technology.
Box PC
SIMATIC Box PCs provide mechanical engineers, plant
engineers and control cabinet makers with particularly rugged
industrial PC systems for use in powerful yet compact applications.

5

Ruggedness and industrial compatibility
for 24-hour continuous use in an industrial environment
• Compact, space-saving enclosure (Box PC and Panel PC)
• Suitable for installing in space-saving control cabinets, only
500 mm deep (Rack PC)
• All-metal enclosure with a high degree of electromagnetic
compatibility for use in industrial areas and in domestic,
business and commercial environments and for a degree of
protection up to IP65/NEMA 4
• The mounting position of the devices can be varied by means
of wall, portrait or control cabinet mounting (Box PC), rail
mounting (SIMATIC IPC427D or IPC227D only) and horizontal
or vertical mounting position in the 19" cabinet or with the
appropriate kit as an industrial tower PC (Rack PC).
• High resistance to shock/vibration thanks to special hard disk
mountings, locked connectors, and card retainers
• Maintenance-free, due to design without hard disk and fans
using SIMATIC CompactFlash cards or solid-state drive
(SIMATIC IPC427D/IPC477D and SIMATIC IPC227D/
IPC277D)
• Service-friendly, modular device design for replacement of
defective components
• Integral industrial power supplies (according to NAMUR) for
safe power supplies protected against system disturbances
• Attractive product design with dirt-repelling fronts and coated
surfaces
• Dust protection thanks to a pressurized cooling concept, frontmounted fans and dust filters (Rack PC)

■ More information
Notes on the scope of delivery

Panel PC

Microsoft operating systems are pre-installed in an OEM version.

SIMATIC Panel PCs are suitable thanks to their high industrial
compatibility for use in control cabinets, consoles and control
panels, as well as directly on the machine. Typical areas of application can be found in both factory and process automation.

The scope of supply also includes:
• Recovery CD for simple reinstallation of the operating system
(not for Windows Embedded)
• Restore DVD (hard disk image) for fast and very easy
restoration of the PC delivery status
• SIMATIC IPC Documentation and Drivers DVD
• Compact Operating Instructions
(German/English/French/Spanish/Italian/Chinese)
• Electronic manual on IPC Documentation and Drivers DVD
(German/English)

Industrial monitors and thin clients
Flexible operator input concepts can be implemented via Flat
Panel monitors or thin clients. These are industry-standard LCD
monitors with high-contrast displays that can be located up to
30 m away from the PC, or low-cost, rugged thin clients that offer
HMI functionality over the network in larger plants spread over
wide areas.

Further information can be found in the Internet at:
http://www.siemens.com/simatic-ipc
Information material for ordering and for downloading is
available on the Internet:
http://www.siemens.com/simatic/printmaterial

5/2

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
Rack PC
Rack PC

■ Overview

Rack PCs are flexible, high-availability industrial PC systems for
powerful yet compact applications using 19" technology.
Three device classes are available for various requirements:
SIMATIC IPC547 – maximum performance at an attractive price
SIMATIC IPC647 – maximum compactness combined with
maximum industrial functionality
SIMATIC IPC847 – maximum expandability and industrial
functionality

Shared industrial functionality
• Maximum system performance for complex automation tasks
and computationally intensive PC tasks in the industrial
environment through use of Intel Core processors
• Designed for 24-hour continuous operation
• Monitoring and diagnostics functions
(e.g. temperature, fan, watchdog)
• RAID1 configuration (mirrored drives), optionally in "hot swap"
frames
• Hard disks with capacities up to 1 TB for large volumes of data
• Solid-state drive (SSD) with SLC technology, optional
• Compact dimensions for installation in control cabinets only
500 mm deep
• Dust protection thanks to overpressure ventilation concept
with fan on the front and dust filter
• Lockable front panel or front door
• Service-friendly equipment design due to prepared telescopic
rail mounting
• Universal implementation as an industrial workstation or
server
• Operating system preinstalled and activated for fast startup
• Fast restoration of the delivery status of the HDD thanks to
restore DVD
• High flexibility and expandability of components
• PCI and PCI Express expansion slots
• Independent industrial product design

5

Siemens ST 80 / ST PC · 2013

5/3

© Siemens AG 2013

PC-based Automation
Rack PC
Rack PC

■ Overview (continued)
SIMATIC IPC547D –
maximum performance at an attractive price
• Intel Core i processors 2nd generation
• Maximum processor performance in maximum configuration
without loss of power (throttling) at ambient temperatures of up
to 40 °C
• Optional RAID5 configuration (striping with parity) in
"hot swap" frames
• Redundant AC power supply, optional
• Low noise output thanks to controlled fans
• Status and alarm LEDs at the front for signaling critical system
states
• Availability for at least 1.5 years
• Guaranteed spare parts availability for at least 3 years

5

SIMATIC IPC647C – maximum compactness combined with
maximum industrial functionality
• Maximum compactness due to 3 free PCI/PCI Express slots
for installing long expansion cards and integrated interfaces
for communication, e.g. integrated PROFIBUS/MPI or
PROFINET interface
• High thermal stability up to 50°C even at maximum processor
performance
• High vibration/shock resistance thanks to special hard disk
holders
• Intel Core i processors
• Enhanced server functionality:
Hardware RAID PCIe x8 controller with zero-maintenance
cache protection module, SAS hard disks in hot-swap frame
with capacities up to 1 TB for large volumes of data
• Redundant AC power supply, optional
• ECC memory, optional
• Service-friendly device design due, for example, to the
replacement of filters/fans from the front without the need for
tools, or opening of the enclosure with just one screw.
• Front LED concept for efficient self-diagnostics, e.g.
monitoring of the hard disks in RAID1 configurators, fans or
the status display for Ethernet, PROFINET and PROFIBUS.
• Integrated PROFIBUS DP/MPI or PROFINET interface
(optional)
• High continuity of the components/design
• Motherboard developed and manufactured by Siemens
• Availability for up to 6 years
• Guaranteed spare parts availability for at least 5 years

5/4

Siemens ST 80 / ST PC · 2013

SIMATIC IPC847C – maximum expandability and industrial
functionality
• Maximum expandability due to 11 free PCI/PCI Express slots
for installing long expansion cards and integrated interfaces
for communication, e.g. integrated PROFIBUS/MPI or
PROFINET interface
• High thermal stability up to 50°C even at maximum processor
performance
• High vibration/shock resistance thanks to special hard disk
holders
• Intel Core i processors
• Optional RAID5 configuration (striping with parity)
in "hot swap" frames
• Extended server functionality:
Hardware RAID PCIe x8 controller, SAS hard disks in hot-swap
frame with capacities up to 1 TB for large volumes of data
• Redundant AC power supply, optional
• SATA hard disks with capacities up to 500 GB for large
volumes of data
• ECC memory, optional
• Service-friendly device design due, for example, to the
replacement of filters/fans from the front without the need for
tools, or opening of the enclosure with just one screw.
• Front LED concept for efficient self-diagnostics, e.g.
monitoring of the hard disks in RAID1 configurators, fans or
the status display for Ethernet, PROFINET and PROFIBUS.
• Integrated PROFIBUS DP/MPI or PROFINET interface
(optional)
• High continuity of the components/design
• Motherboard developed and manufactured by Siemens
• Availability for up to 6 years
• Guaranteed spare parts availability for at least 5 years

© Siemens AG 2013

PC-based Automation
Rack PC
Rack PC

■ Overview (continued)
SIMATIC IPC547D

SIMATIC IPC647C

SIMATIC IPC847C

19" rack

4 HU

2 HU

4 HU

Prepared for telescopic rails

•

•

•

Horizontal/vertical installation

•/•

•/-

•/•

19" mounting bracket can be removed
from outside

•

•

•

Tower Kit (optional)

•

-

•

Processor

• Intel Core i7-2600
(4C/8T, 3.40 GHz)
• Intel Core i5-2400
4C/4T, 3.10 GHz)
• Intel Pentium G850
(2C/2T, 2.90 GHz)

• Intel Core i7-610E
(2C/4T, 2.53 GHz)
• Intel Core i5-520E
(2C/4T, 2.4 GHz)
• Intel Core i3-330E
(2C/4T, 2.13 GHz)

• Intel Core i7-610E
(2C/4T, 2.53 GHz)
• Intel Core i5-520E
(2C/4T, 2.4 GHz)
• Intel Core i3-330E
(2C/4T, 2.13 GHz)

Main memory

• 1 GB, expandable up to 32 GB

• 1 GB, expandable up to 8 GB
• ECC optional

• 1 GB, expandable up to 8 GB
• ECC optional

Slots for expansions
(all long, up to 312 mm)

•
•
•
•

• 2 x PCI
• 1 x PCI Express x16

• 7 x PCI
• 1 x PCI Express x16
• 3 x PCI Express x4

Design

General features

4 x PCI
1 x PCI Express x16
1 x PCI Express x16 (4 lanes)
1 x PCI Express x8
(1 lane)

or
• 1 x PCI
• 1 x PCI Express x8 (4-lane)
• 1 x PCI Express x16

or
• 7 x PCI
• 1 x PCI Express x16

Onboard graphics

• 1 x DisplayPort
• 1 x DVI-I
• 1 x VGA
(via adapter cable, optional)

• 1 x DVI-I
• 1 x VGA
(via adapter cable, optional)

• 1 x DVI-I
• 1 x VGA
(via adapter cable, optional)

Graphics card (optional)

• PCI Express x16
(2 x VGA or 2 x DVI-D)

• PCI Express x16
(2 x VGA or 2 x DVI-D)

• PCI Express x 16
(2 x VGA or 2 x DVI-D)

without

•

•

•

Preinstalled and activated,
supplied on restore DVD

• Windows XP Professional
Multi-Language (32-bit)
• Windows 7 Ultimate Multi-Language
(32/64-bit)
• Windows Server 2008 incl. 5 Client
Multi-Language (32-bit)
• Windows Server 2008 R2 incl.
5 Clients Multi-Language (64-bit)

• Windows XP Professional
Multi-Language (32-bit)
• Windows 7 Ultimate Multi-Language
(32/64-bit)
• Windows Server 2003 R2 incl.
5 Clients Multi-Language (32-bit)
• Windows Server 2008 incl. 5 Clients
Multi-Language (32-bit)
• Windows Server 2008 R2 incl.
5 Clients Multi-Language (64-bit)

• Windows XP Professional
Multi-Language (32-bit)
• Windows 7 Ultimate Multi-Language
(32/64-bit)
• Windows Server 2003 R2 incl.
5 Clients Multi-Language (32-bit)
• Windows Server 2008 incl. 5 Clients
Multi-Language (32-bit)
• Windows Server 2008 R2 incl.
5 Clients Multi-Language (64-bit)

Order separately

-

RMOS3 V3.50

RMOS3 V3.50

Project-specific on request

• Linux 1)
• Other

• Linux 1)
• Other

• Linux 1)
• Other

PROFIBUS/MPI

-

12 Mbit/s (CP 5611-compatible),
optional

12 Mbit/s (CP 5611-compatible),
optional

PROFINET

-

3 x RJ45 (CP 1616-compatible),
optional

3 x RJ45 (CP 1616-compatible),
optional

Ethernet

2 x 10/100/1000 Mbit/s

2 x 10/100/1000 Mbit/s

2 x 10/100/1000 Mbit/s

USB 2.0 (high current)

11 x, 2 of which at front, 1 x internal

7 x , 2 of which at front, 1 x internal

7 x , 2 of which at front, 1 x internal

VGA

• optional

• optional

• optional

DVI

•

•

•

DisplayPort

•

-

-

Operating system

Interfaces

Siemens ST 80 / ST PC · 2013

5/5

5

© Siemens AG 2013

PC-based Automation
Rack PC
Rack PC

■ Overview (continued)
SIMATIC IPC547D

SIMATIC IPC647C

SIMATIC IPC847C

•
•

•

•
•

-

•

•

RAID1/5 configuration
with onboard RAID

•/•

•/-

• /•

Solid-state drive (SSD), SLC

•

•

•

Installation at the front in the swap
frame

-

•

•

RAID1/5 configuration with HW RAID
controller PCI x 8 incl. zero maintenance cache protection module

-/-

•/-

• /•

DVD-ROM

•

-

•

DVD±R/RW

•

•

•

AC power supply

•

•

•

Redundant (optional)

•

•

•

Vibration/shock load
during operation

0.2 g / 1 g

0.5 g / 5 g

0.5 g / 5 g

Ambient temperature
during operation

With maximum configuration:
5 ... 40 °C

With maximum configuration:
5 ... 50 °C

With maximum configuration:
5 ... 50 °C

Drives
SATA hard disks
• Internal installation
• Installation at the front in the swap
frame
• Internal installation in drive holder
(shock and vibration-damped)

Hard disks SAS

Optical drives

Ambient conditions 2)

• Available
- Not available

5

1)

Suitable for specific Linux versions in accordance with the specifications
of the Siemens manufacturer's declaration "Suitable for Linux", see
http://www.siemens.com/simatic-pc/suited-for-linux
(Linux is a trademark of Linus Torvald)

2)

Restrictions when using DVD±R/RW and hard disks in swap frame.

■ More information
Further information can be found in the Internet under:
http://www.siemens.com/simatic-pc
Information material can be ordered or downloaded from the
Internet:
http://www.siemens.com/simatic/printmaterial

5/6

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
Rack PC
SIMATIC IPC547D

■ Overview

■ Technical specifications
SIMATIC IPC547D
General features
Design

19" rack, 4 HU, externally painted

Processor

• Intel Core i7-2600
(4C/8T, 3.40 GHz, 8 MB Last Level
Cache, Turbo Boost 2.0, EM64T,
VT-x/-d, iAMT)
• Intel Core i5-2400
(4C/4T, 3.10 GHz, 6 MB Last Level
Cache, Turbo Boost 2.0, EM64T,
VT-x/-d, iAMT)
• Intel Pentium Dual Core G850
(2C/2T, 2.90 GHz, 3 MB Last Level
Cache, EM64T, VT)

Chipset

• Intel Q67

Main memory

•
•
•
•

From 1 GB DDR3 1333 SDRAM
Dual channel support
4 DIMM base
Expandable up to 32 GB 1)

Spare slots for expansions (all long)

•
•
•
•

4 x PCI
1 x PCI Express x16
1 x PCI-Express x16 (4 lanes)
1 x PCI-Express x8 (1 Lane)

Graphics

• Onboard Intel HD 2000 graphics
controller integrated into the processor; Shared Video Memory up
to 1.7 GB; up to 2560 x 1600 pixels at 60 Hz image refresh rate
and 32-bit colors
• PCI Express graphics card (Dual
Head: 2 x VGA or 2 x DVI-D) in the
PCIe x16 slot; 512 MB; up to
2048 x 1536 pixels at 85 Hz image refresh rate and 32 bit colors
(optional)

Operating system

• without

The SIMATIC IPC547D is a rugged industrial PC in 19" rack
design (4 HU).
It offers:
• Maximum performance
• Attractive price
• Intel Core i technology

Preinstalled and activated
(supplied on restore DVD):
• Windows XP Professional MUI
(32-bit)
• Windows 7 Ultimate MUI
(32/64-bit)
• Windows Server 2008 incl.
5 Client MUI (32 bit)
• Windows Server 2008 R2 incl.
5 Client MUI (64 bit)
MUI (Multilanguage User Interface,
5 languages): English, German,
French, Italian, Spanish
Project-specific on request:
• Linux 2)
• Other
Power supply

• 100 ... 240 V AC, 50 ... 60 Hz, with
bridging of short-term power failures: max. 20 ms at 0.85% rated
voltage
• Redundant 100 ... 240 V AC,
50 ... 60 Hz

1)

Memory information:
In order to use a memory with more than 4 GB, a 64-bit operating system is
required. In the case of configurations with 4 GB, the visible memory can
be reduced to about 3.5 GB or less (with 32-bit operating systems).
In configurations with 8 GB, the visible memory can be reduced to about
7.5 GB or less.

2)

Suitable for specific LINUX versions in accordance with the specifications
of the Siemens manufacturer's declaration "Suitable for LINUX", see
http://www.siemens.com/simatic-pc/suited-for-linux
(LINUX is a trademark of Linus Torvald).

Siemens ST 80 / ST PC · 2013

5/7

5

© Siemens AG 2013

PC-based Automation
Rack PC
SIMATIC IPC547D

■ Technical specifications (continued)
SIMATIC IPC547D
Drives

SIMATIC IPC547D
Monitoring functions

Hard disk, SATA 3.5"
with NCQ technology
Solid State Drive, SATA 2.5"
with SLC technology

Installation in internal drive support
• 500 GB
• 1 TB
• RAID1 3) 1 TB
(2 x 1 TB, mirror disks)
• 50 GB solid-state drive
Installation at the front in swap
frame (low profile)
• 500 GB
• 2 x 500 GB
• RAID1 3) 1 TB (2 x 1 TB, mirror
disks), "hot swap"
• RAID5 3) 2 TB (3 x 1 TB, striping
with parity), "hot swap"
• 50 GB solid-state drive
• RAID1 3) 1 TB (2 x 1 TB, mirror
disks), "hot swap" + 50 GB solidstate drive (operating system installed on SSD if configured)

DVD-ROM, 5.25", SATA

• 16 x (DVD media)
• 32 x (CD media)

DVD±R/RW, 5.25", SATA

• 16 x 24 x 8 x (DVD media)
• 48 x 48 x 32 x (CD media)

Slots for drives

Front:
• 3 x 5.25"
• 1 x 3.5"

Basic functionality

Message locally
via DiagBase software

Temperature

When permitted operating temperature range is exceeded

Fan

Speed monitoring
• 1 x front fan
• 1 x CPU fan
• 1 x power supply fan

Watchdog

• Monitoring of program execution
• Monitoring time can be parameterized in software

Monitoring functions via the network

SIMATIC IPC DiagMonitor Version
V4.3.x.x or higher (optional)
Remote monitoring capability for:
• Watchdog
• Temperature
• Fan speed
• Battery
• Hard disks (SMART)
• System/Ethernet
Communication:
• Ethernet interface
(SNMP protocol)
• OPC for integration
in SIMATIC software
• Client server architecture
• Structure of log files

Internal:
• 2 x 3.5"
Front LEDs

Interfaces

5

Ethernet

2 x Intel Gbit Ethernet
(RJ45, teaming-capable)

USB 2.0

• 2 x front (high current)
• 8 x rear (high current)
• 1 x internal (high current),
e.g. for USB dongle with
optional interlocking

Serial

9-pole COM1 (V.24);
COM2 (V.24) (optional)

Parallel

LPT (optional)

VGA

Optionally via adapter cable

DVI-I

1x

DisplayPort

1x

Keyboard

PS/2

Mouse

PS/2

Audio

1 x Line In; 1 x Line Out; 1 x Micro

3)

SATA RAID controller onboard in Intel Q67 chipset

4)

Restrictions in use of optical drives and HDD in swap frames.

5/8

Siemens ST 80 / ST PC · 2013

•
•
•
•

POWER (PC switched on)
HDD (access to hard disk)
TEMP (temperature monitoring)
FAN (fan monitoring)

Additional HDD alarm LEDs for
RAID configurations behind the
front flap
Ambient conditions
Degree of protection

IP30 front, IP20 rear according to
EN 60529

Dust protection

With the front door closed according to IEC 60529 filter class G2
EN 779, 99% of particles > 0.5 mm
are filtered

Protection class

Protection class I according to
IEC 61140

Vibration load during operation 4)

IEC 60068-2-6, 10 cycles
• 20 ... 58 Hz: 0.015 mm
• 58 ... 200 Hz: 2 m/s2
(approx. 0.2 g)

Shock load in operation 4)

IEC 60068-2-27
• Half-sine: 9.8 m/s2, 20 ms
(approx. 1 g),
100 shocks per axis

© Siemens AG 2013

PC-based Automation
Rack PC
SIMATIC IPC547D

■ Technical specifications (continued)
SIMATIC IPC547D
Electromagnetic compatibility (EMC)
Emitted interference

SIMATIC IPC547D
Approvals and safety regulations

EN 61000-6-3; EN 61000-6-4;
CISPR 22 / EN 55022 Class B;
FCC Class A;
EN 61000-3-2 Class D;
EN 61000-3-3

Immunity to conducted interference on
the supply lines

• ± 2 kV (IEC 61000-4-4, burst)
• ± 1 kV
(IEC 61000-4-5, symm. surge)
• ± 2 kV
(IEC 61000-4-5, asymm. surge)

Immunity to interference on signal lines

• ±2 kV (IEC 61000-4-4, burst,
length > 30 m)
• ± 1 kV (IEC 61000-4-4, burst,
length < 30 m)
• ± 2 kV (IEC 61000-4-5, surge,
length > 30 m)

Immunity to static discharge

• ± 4 kV, contact discharge
(IEC 61000-4-2)
• ±8 kV, air discharge
(IEC 61000-4-2)

Immunity to high radio frequency interference

• 1 V/m 80% AM; 2 ... 2.7 GHz
(IEC 61000-4-3)
• 10 V/m 80% AM;
80 MHz ... 1 GHz and
1.4 GHz … 2 GHz
(IEC 61000-4-3);
• 10 V, 10 kHz ... 80 MHz
(IEC 61000-4-6)

Immunity to magnetic fields

100 A/m, 50/60 Hz (IEC 61000-4-8)

Ambient temperature during operation

5 ... 40 °C

Safety regulations

IEC 60950-1; UL60950; CSA

Approvals

cULus 60950

CE mark

For use in industrial areas as well
as domestic, business and commercial environments:
• Emitted interference:
EN 61000-6-3:2007
• Noise immunity:
EN 61000-6-2:2005

Dimensions and weights
Mounting dimensions (W x H x D)
in mm

434 x 177 x 446

Weight, approx.

19 kg

Note:
Limitations for operation
of DVD±R/RW
Humidity during operation

5 ... 80% at 25 °C
(no condensation)

Note regarding SIMATIC PC operating system licenses
The accompanying operating system license is only valid for
installation on the respective supplied SIMATIC IPC. Installation
can only be performed on these SIMATIC systems in accordance with Microsoft OEM licensing regulations.

Siemens ST 80 / ST PC · 2013

5/9

5

© Siemens AG 2013

PC-based Automation
Rack PC
SIMATIC IPC547D

■ Ordering data
SIMATIC IPC547D

Order No.
1)

Order No.

6AG4104- 2 7 7 7 7 - 7 7 7 7

Interfaces:
2 x Gbit Ethernet (RJ45),
1 x DisplayPort, 1 x DVI-I,
8 x USB on the rear,
2 x USB on the front,
1 x USB internal,
1 x serial (COM1), 2 x PS/2,
audio; 7 slots (all long):
4 x PCI, 1 x PCIe x16,
1 x PCIe x16 (4 lanes),
1 x PCIe x8 (1 lane);
mounting locations:
6 (3 x 5.25", 1 x 3.5" externally
accessible; 2 x 3.5" internal);
temperature and fan monitoring;
watchdog; card retainer
Processors
• Pentium Dual Core G850
(2C/2T, 2.90 GHz, 3 MB Last Level
Cache, EM64T, VT)
• Core i5-2400 (4C/4T, 3.10 GHz,
6 MB Last Level Cache, Turbo
Boost 2.0, EM64T, VT-x/-d, iAMT)
• Core i7-2600 (4C/8T, 3.40 GHz,
8 MB Last Level Cache, Turbo
Boost 2.0, EM64T, VT-x/-d, iAMT)

5

Drives
• 500 GB HDD SATA; internal
• 1 TB HDD SATA; internal
• RAID1, 1 TB (2 x 1 TB HDD SATA,
mirror disks); internal 2)
• 50 GB solid-state drive (SLC)
SATA; internal
• 500 GB HDD SATA in swap frame;
front
• 2 x 500 GB HDD SATA in swap
frame; front
• RAID1, 1 TB (2 x 1 TB HDD SATA,
mirror disks) in swap frame; for hot
swapping; at the front
• RAID5, 2 TB (3 x 1 TB HDD SATA,
striping with parity) in swap frame;
for hot swapping; at the front
• 50 GB solid-state drive (SLC) SATA
in swap frame; at the front
• RAID1, 1 TB (2 x 1 TB HDD SATA,
mirror disks) in swap frame; hot
swapping; at the front + 50 GB solid-state drive (SLC) SATA in swap
frame; at the front (operating system installed on SSD, if configured)
Memory configuration
• 1 GB DDR3 SDRAM
(1 x 1 GB), single channel
• 2 GB DDR3 SDRAM
(2 x 1 GB), dual channel
• 4 GB DDR3 SDRAM
(2 x 2 GB), dual channel
• 8 GB DDR3 SDRAM 3)
(2 x 4 GB), dual channel
• 16 GB DDR3 SDRAM 3)
(4 x 4 GB), dual channel
• 32 GB DDR3 SDRAM 3)
(4 x 8 GB), dual channel

Removable media
• DVD-ROM
• DVD±RW
Expansions (hardware)
• Without expansions (HW);
onboard graphics
• No expansions (HW); onboard
graphics; DVI-I VGA-compliant
adapter cable for onboard
graphics
• Serial (COM2) & parallel (LPT);
onboard graphics
• Serial (COM2) and parallel (LPT);
onboard graphics; DVI-I VGAcompliant adapter cable for onboard graphics
• Serial (COM2) & parallel (LPT)
+ PCIe x16 graphics card (Dual
Head: 2 x VGA or 2 x DVI-D),
512 MB

A

C

Operating systems
(preinstalled and activated)
• Windows XP Professional, MUI
(Eng, Ger, Fr, It, Sp), 32-bit, SP3
• Windows 7 Ultimate, MUI
(Eng, Ger, Fr, It, Sp), 32 bit,
SP1 enclosed
• Windows 7 Ultimate, MUI
(Eng, Ger, Fr, It, Sp), 64 bit,
SP1 enclosed
• Windows Server 2008 Standard
Edition incl. 5 Client, MUI
(Eng, Ger, Fr, It, Sp), 32 bit, SP2
• Windows Server 2008 R2 Standard
Edition incl. 5 clients, MUI
(Eng, Ger, Fr, It, Sp), 64 bit,
SP1 enclosed
• Without operating system

D

A
B
D
E
G
H
P

Expansions (software)
• SIMATIC IPC DiagMonitor V4.3
software included
• SIMATIC IPC Image & Partition
Creator V3.2 software included
• SIMATIC IPC DiagMonitor V4.3 +
Image & Partition Creator V3.2
software included
• Without expansions (software)

R

S
T

0
1
2
3
4
5

1)

For an up-to-date overview, see the SIMATIC PC online configurator at:
www.siemens.com/ipc-configurator

2)

Not in combination with redundant power supply

3)

Can only be used on 64-bit operating systems

5/10

Siemens ST 80 / ST PC · 2013

SIMATIC IPC547D
(continued)

1)

Power supply, with country-specific
cable:
• 100/240 V AC industrial power
supply; power cable for Europe
• 100/240 V AC industrial power
supply; USA power cable
• 100/240 V AC industrial power
supply; power cable for China
• 2 x 100/240 V AC redundant industrial power supply; without power
cable

6AG4104- 2 7 7 7 7 - 7 7 7 7

1
2
0
1

2
3

4

B
E

F

P

Q

X
A
B
C

X

0
4
5
6

© Siemens AG 2013

PC-based Automation
Rack PC
SIMATIC IPC547D

■ Ordering data

Order No.

Preferred variants (ex-stock)
SIMATIC IPC547D
• Pentium Dual Core G850
(2C/2T, 2.90 GHz, 3 MB Last Level
Cache, EM64T, VT); 500 GB HDD
SATA internal; 1 GB DDR3 SDRAM
(1 x 1 GB), single channel;
DVD-ROM; interfaces:
2 x Gbit Ethernet (RJ45),
1 x serial, 8 x USB rear,
2 x USB front, 1 x USB internal,
2 x PS/2, audio;
100/240 V industrial power supply,
power cable for Europe;
without operating system
• Core i5-2400 (4C/4T, 3.10 GHz,
6 MB Last Level Cache, Turbo
Boost 2.0, EM64T, VT-x/-d, iAMT);
RAID1, 1 TB (2 x 1 TB HDD SATA,
mirror disks) in swap frame,
for hot swapping, at the front;
4 GB DDR3 SDRAM (2 x 2 GB)
dual channel; DVD±RW;
interfaces: 2 x Gbit Ethernet
(RJ45), 2 x serial, 1 x parallel,
8 x USB rear, 2 x USB front,
1 x USB internal, 2 x PS/2, Audio;
100/240V industrial power supply,
power cable for Europe;
without operating system
• Core i7-2600 (4C/8T, 3.40 GHz,
8 MB Last Level Cache, Turbo
Boost 2.0, EM64T, VT-x/-d, iAMT);
RAID1, 1 TB (2 x 1 TB HDD SATA,
mirror disks) in swap frame,
for hot swapping, at the front;
8 GB DDR3 SDRAM (2 x 4 GB)
dual channel; DVD±RW;
interfaces: 2 x Gbit Ethernet
(RJ45), 2 x serial, 1 x parallel,
8 x USB rear, 2 x USB front,
1 x USB internal, 2 x PS/2, audio;
100/240 V industrial power supply,
power cable for Europe, Windows
7 Ultimate MUI (Eng, Ger, Fr, It,
Sp), 64-bit, SP1 supplied

Order No.
Accessories

6AG4104-2AA01-0XX0

6AG4104-2CP22-2XX0

6AG4104-2DP32-2FX0

Memory expansion
• 1 GB DDR3 1333 SDRAM, DIMM
(1 x 1 GB)
• 2 GB DDR3 1333 SDRAM, DIMM,
kit for dual-channel technology
(2 x 1 GB)
• 4 GB DDR3 1333 SDRAM, DIMM,
kit for dual-channel technology
(2 x 2 GB)
• 8 GB DDR3 1333 SDRAM, DIMM,
kit for dual-channel technology
(2 x 4 GB)

6ES7648-2AJ40-0LA0
6ES7648-2AJ50-0LB0

6ES7648-2AJ60-0LB0

6ES7648-2AJ70-0LB0

Tower Kit
For converting the computer into an
industrial tower PC

6ES7648-1AA00-0XC0

Retainer
for pin assignment of the internal
USB port

6ES7648-1AA00-0XK0

Power cable, straight, 3 m long
• Austria, Belgium, Finland, France,
Germany, Netherlands, Spain,
Sweden
• United Kingdom
• Switzerland
• USA
• Italy
• China

6ES7900-0AA00-0XA0

6ES7900-0BA00-0XA0
6ES7900-0CA00-0XA0
6ES7900-0DA00-0XA0
6ES7900-0EA00-0XA0
6ES7900-0FA00-0XA0

Rack unit for low-profile
HDD swap frame
for 3.5" hard disk, SATA
(without hard disk)

6ES7648-0EG00-1BA0

Expansion components

From page 5/153

5
Note:
Software Packages with SIMATIC WinCC flexible,
SIMATIC WinCC RT Advanced, SIMATIC WinCC, and
SIMATIC WinAC RTX (F) can be ordered together with the
SIMATIC IPC at favorable prices.
More information under
"Embedded Bundles / Packages for industrial PCs".

Siemens ST 80 / ST PC · 2013

5/11

© Siemens AG 2013

PC-based Automation
Rack PC
SIMATIC IPC547D

■ Dimensional drawings

■ More information

All dimensions in mm. For mounting cut-out see technical
specifications.

Further information can be found on the Internet at:
http://www.siemens.com/simatic-pc

37.5

465.1

176.5

101.6

481.4

G_ST80_XX_00452

489
18.5

14.3

445.5

433.5

Technical data of the telescopic rails

5

Carrying capacity per pair, min.

30 kg

Full extension length, min.

470 mm

Rail thickness, max.

9.7 mm

Fixing screws

M5 x 6 mm

The fixing screws of the telescopic rails should not project more
than 5 mm into the enclosure.
The enclosure is prepared for the following telescopic rails:
• Rittal: Type 3659.180 for 600 mm cabinet /
Type RP 3659.190 for 800 mm cabinet
• Schroff: Type 20110-072

5/12

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
Rack PC
SIMATIC IPC647C

■ Overview

■ Technical specifications
SIMATIC IPC647C
General features
Design

19" rack, 2 HUs, external coating

Processor

• Intel Core i7-610E
(2C/4T, 2.53 GHz, 4 MB cache,
Turbo Boost, VT-d, iAMT, EM64T)
• Intel Core i5-520E
(2C/4T, 2.4 GHz, 3 MB cache,
Turbo Boost, VT-d, iAMT, EM64T)
• Intel Core i3-330E
(2C/4T, 2.13 GHz, 3 MB cache,
EM64T)

Chipset

Intel QM57

Main memory

•
•
•
•

Spare slots for expansions (all long)

• 2 x PCI
• 1 x PCI Express x16

The SIMATIC IPC647C is a very rugged, high-performance
industrial PC in 19" rack design (2 HMs) with excellent industrial
functionality.
It offers:
• Extreme compactness
• Extreme ruggedness
• Intel Core i technology

from 1 GB DDR3 1066 SDRAM
Dual channel support
2 DIMM slots
Expandable up to 8 GB,
optional ECC 1)

or
• 1 x PCI
• 1 x PCI Express x8 (4 lane)
• 1 x PCI Express x16
Graphics

1)

• Onboard Intel GMA HD graphics
controller integrated into processor; dynamic video memory; up to
2048 x 1536 pixels with 75 Hz
refresh rate and 16-bit colors
• PCI Express graphics card
(Dual Head: 2 x VGA or 2 x DVI-D
via display port adapter) in the
PCIe x16 slot; 256 MB; up to
2048 x 1536 pixels with 75 Hz
refresh rate and 32-bit colors
(optional)

Memory information:
In order to use a memory with more than 4 GB, a 64-bit operating system is
required. In the case of configurations with 4 GB, the visible memory can
be reduced to about 3.5 GB or less (with 32-bit operating systems).
In configurations with 8 GB, the visible memory can be reduced to about
7.5 GB or less.

Siemens ST 80 / ST PC · 2013

5/13

5

© Siemens AG 2013

PC-based Automation
Rack PC
SIMATIC IPC647C

■ Technical specifications (continued)
SIMATIC IPC647C
Operating system

• without
• Preinstalled, activated,
and supplied on restore DVD
• Windows XP Professional MUI,
32-bit
• Windows 7 Ultimate MUI,
32/64-bit
• Windows Server 2003 R2
incl. 5 client MUI, 32-bit
• Windows Server 2008
incl. 5 client MUI, 32-bit
• Windows Server 2008 R2 incl.
5 client MUI, 64-bit
MUI: Multi-language User Interface;
5 languages (English, French,
German, Italian, Spanish)
• Project-specific on request 2)
• Other
• 100 ... 240 V AC, 50 ... 60 Hz;
with bridging of temporary power
failures in accordance with
NAMUR: max. 20 ms at
0.85% rated voltage
• Redundant 100 ... 240 V AC,
50 ... 60 Hz

Power supply

SIMATIC IPC647C
Interfaces
PROFINET

3 x RJ45 (CP 1616-compatible),
optional

PROFIBUS/MPI

12 Mbit/s (isolated, compatible with
CP 5611), optional

Ethernet

2 x 10/100/1000 Mbit/s
(RJ45, teaming-capable)

USB 2.0

• 2 x front (high current)
• 4 x rear (high current)
• 1 x internal (high current), e.g.
for USB dongle with optional lock

Serial

• 9-pin COM1 (V.24)
• 9-pin COM2 (V.24)

Parallel

LPT1

VGA

1x

Keyboard

PS/2

Mouse

PS/2

Audio

1 x Line Out; 1 x Micro

Drives
Hard disks: SATA 3.5" or SAS 3.5"

Mounted in internal shock/
vibration-resistant drive cage
• 250 GB
• 500 GB
• 2 x 500 GB
• 500 GB RAID1 3),
(2 x 500 GB, mirror disks)
Mounted in front drive cage
in swap frame (low profile)
• 250 GB
• 500 GB
• 2 x 500 GB
• 500 GB RAID1 3),
(2 x 500 GB, mirror disks),
"hot swap"
• 1 TB RAID1,
(2 x 1 TB HDD SAS, mirror disks),
"hot swap"; RAID controller in
PCIe x8 slot with zero-maintenance cache protection module

5
Solid-State Drive (SSD) (2.5" SATA)

Installed internally or front-mounted
in removable frame
• 50 GB (SLC), optional

DVD+/-R/RW, slimline

• 8 x 8 x 6 x (DVD media)
• 24 x 24 x 24 x (CD media)

Slots for drives

Front:
• 2 x low profile swap frames
(for 3.5" HDD)
• 1 x 12.7 mm slimline
(for ODD or CF drive)
Internal:
• 2 x 3.5" as an alternative to swap
frames (in the optional, shock and
vibration-damped drive cage)

5/14

Siemens ST 80 / ST PC · 2013

2)

Suitable for specific LINUX versions in accordance with the specifications
of the Siemens manufacturer's declaration "Suitable for LINUX", see
(LINUX is a trademark of Linus Torvald).

3)

SATA RAID controller on board in Intel chipset

© Siemens AG 2013

PC-based Automation
Rack PC
SIMATIC IPC647C

■ Technical specifications (continued)
SIMATIC IPC647C
Monitoring functions

SIMATIC IPC647C
Ambient conditions

Basic functionality

Message locally via DiagBas
e software

Degree of protection

IP41 at the front, IP20 at the rear
acc. to EN 60529

Temperature

• Overshoot/undershoot of permissible operating temperature range
• Messages can be evaluated by
the application program

Dust protection

with front door closed: G2 EN 779,
99% of particles > 0.5 mm are held
back

Protection class

Fan

• Speed monitoring
• 2 x enclosure fan (front)
• 1 x power supply fan

Protection class I in accordance
with IEC 61140

Vibration load during operation

DIN EN 60068-2-6, 10 cycles

Watchdog

• Monitoring of program execution
• Monitoring time can be parameterized in software
• Restart can be parameterized in
the event of a fault
• Messages can be evaluated by
the application program

Monitoring functions via the network

SIMATIC IPC DiagMonitor (optional)
Version 4.3 and higher
Remote monitoring capability for:
• Watchdog
• Temperature
• Fan speed
• Hard disk monitoring (SMART)
• Redundant power supply
(module)
• System/Ethernet monitoring
(Heartbeat)
Communication:
• Ethernet interface
(SNMP protocol)
• OPC for integration in
SIMATIC software
• Configuration of
client/server architectures
• Structure of log files

Front LEDs

• POWER (internal power supply
unit, PC switched on)
• HARDDISK (access to hard disk)
• ETHERNET1
(Ethernet status, "Heartbeat")
• ETHERNET2
(Ethernet status, "Heartbeat")
• PROFIBUS/MPI
(PROFIBUS status)
• SF PROFINET (PROFINET status)
• WATCHDOG
(ready/fault indication)
• TEMP (temperature status)
• FAN (fan speed monitoring)
• HDD1 ALARM (hard disk alarm
in conjunction with RAID1 and
monitoring software)
• HDD2 ALARM (hard disk alarm
in conjunction with RAID1 and
monitoring software)

Internal mounting of the hard disk
drives in optional, internal drive
cage:
• 10 ... 58 Hz: 0.0375 mm;
• 58 ... 500 Hz: 5 m/s2
(approx. 0.5 g)
Note:
There are limitations when
DVD+/-RW and HDD are operated
in a swap frame
Shock loading during operation

DIN EN 60068-2-27,
IEC 60068-2-29
Internal mounting of the hard disk
drives in optional, internal drive
cage:
• Half-sine: 50 m/s2, 30 ms
(ca. 5 g), 100 shocks per axis
Note:
There are limitations when
DVD+/-RW and HDD are operated
in a swap frame

Electromagnetic compatibility (EMC)
Emitted interference (AC)

EN 61000-6-3, EN 61000-3-3,
EN 61000-3-2 Class D;
FCC Class A

Immunity to conducted interference on
the supply lines

± 2 kV (IEC 61000-4-4, burst)
± 1 kV
(IEC 61000-4-5, symm. surge)
± 2 kV
(IEC 61000-4-5, asymm. surge)

Immunity to interference on signal lines

± 1 kV (IEC 61000-4-4, burst,
length < 30 m)
± 2 kV (IEC 61000-4-4, symm.
surge, length > 30 m)
± 2 kV (IEC 61000-4-5, asymm.
surge, length > 30 m)

Siemens ST 80 / ST PC · 2013

5/15

5

© Siemens AG 2013

PC-based Automation
Rack PC
SIMATIC IPC647C

■ Technical specifications (continued)
SIMATIC IPC647C
Immunity to static discharge

±6 kV, contact discharge
(IEC 61000-4-2)
±8 kV, air discharge
(IEC 61000-4-2)

Immunity to high radio frequency
interference

• 1 V/m 80% AM 1 kHz;
2 ... 2.7 GHz (IEC 61000-4-3)
• 10 V/m 80% AM 1 kHz;
80 MHz - 1 GHz and
1.4 GHz - 2 GHz (IEC 61000-4-3);
• 10 V, 10 kHz to 80 MHz
(IEC 61000-4-6)

Immunity to magnetic fields

100 A/m, 50/60 Hz (IEC 61000-4-8)

Ambient temperature during operation

5 … 50 °C
Note:
There are limitations when
DVD+/-RW and HDD are operated
in a swap frame

Relative operating humidity

5 ... 85 % at 30 °C
(no condensation)

Approvals and safety regulations
Safety regulations

IEC 60950-1 Second Edition,
EN 60950-1, UL 60950,
CSA C22.2 No 60950

Approvals

cULus 60950, KCC

Marine approval
(only for configurations with
CompactFlash or SSD memory)

•
•
•
•

CE mark

Use in industry:
• Noise immunity:
EN 61000-6-2:2005

5

GL –- Germanische Lloyd
BV – Bureau Veritas
LR – Lloyds Register of Shipping
ABS – American Bureau of
Shipping
• DNV – Det Norske Veritas
• NKK – Nippon Kaiji Kyokai

Use in domestic environments:
• Emitted interference:
EN 61000-6-3:2007
Dimensions and weights
Mounting dimensions
(W x H x D, in mm)

430 x 88 x 445

Note regarding SIMATIC PC operating system licenses
The accompanying operating system license is only valid for
installation on the respective supplied SIMATIC IPC. Installation
can only be performed on these SIMATIC systems in accordance with Microsoft OEM licensing regulations.

5/16

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
Rack PC
SIMATIC IPC647C

■ Ordering data
SIMATIC IPC647C

Order No.
1)

Order No.

6AG4112- 1 7 7 7 7 - 7 7 7 7

Interfaces:
2 x 10/100/1000 Mbps Ethernet
(RJ45); 1 x graphic (DVI-I);
2 x COM; 1 x LPT; 2 x PS/2;
4 x USB 2.0 at rear, 2 x USB 2.0
at front; 1 x USB 2.0 internal; audio;
temperature and fan monitoring,
watchdog; card retainer
Processor/motherboard
• Core i3-330E
(2C/4T, 2.13 GHz, 3 MB cache),
motherboard without fieldbus
• Core i3-330E
(2C/4T, 2.13 GHz, 3 MB cache),
motherboard with PROFIBUS/MPI
• Core i3-330E
(2C/4T; 2.13 GHz, 3 MB cache),
motherboard with PROFINET
(3 x RJ45, CP 1616-compatible) 2)
• Core i5-520E
(2C/4T, 2.4 GHz, 3 MB cache,
TB, iAMT, VT), motherboard
without fieldbus
• Core i5-520E
(2C/4T, 2.4 GHz, 3 MB cache,
TB, iAMT, VT), motherboard with
PROFIBUS/MPI
• Core i5-520E
(2C/4T; 2.4 GHz, 3 MB cache,
TB, iAMT, VT), motherboard with
PROFINET (3 x RJ45,
CP 1616-compatible) 2)
• Core i7-610E (2C/4T, 2.53 GHz,
4 MB cache, TB, iAMT, VT),
motherboard without field bus
• Core i7-610E (2C/4T, 2.53 GHz,
4 MB cache, TB, iAMT, VT),
motherboard with PROFIBUS/MPI
• Core i7-610E
(2C/4T; 2.53 GHz, 4 MB cache,
TB, iAMT, VT), motherboard with
PROFINET (3 x RJ45,
CP 1616-compatible) 2)
Hard disks:
• 250 GB HDD SATA; 0.5 g vibration,
5 g shock, internal
• 500 GB HDD SATA; 0.5 g vibration,
5 g shock, internal
• 2 x 500 GB HDD SATA; 0.5 g vibration, 5 g shock, internal
• RAID1 500 GB (2 x 250 GB HDD
SATA, mirror disks); 0.5 g vibration,
5 g shock, internal
• 250 GB HDD SATA in swap frame;
front
• 500 GB HDD SATA in swap frame;
front
• 2 x 500 GB HDD SATA in swap
frame; front
• RAID1 500 GB (2 x 250 GB HDD
SATA) in swap frame, for hot swapping; front
• 50 GB SSD (SLC) SATA, internal
• 50 GB SSD (SLC) SATA in swap
frame; front
• RAID1 1 TB (2 x 1 TB HDD SAS) in
swap frame, for hot-swapping,
front; PCIe x8 RAID controller with
zero-maintenance cache protection module in PCIe x16 slot 3)

SIMATIC IPC647C
(continued)

1)

6AG4112- 1 7 7 7 7 - 7 7 7 7

Memory configuration:
• 1 GB DDR3 SDRAM (1 x 1 GB),
single channel
• 2 GB DDR3 SDRAM (1 x 2 GB),
single channel
• 4 GB DDR3 SDRAM (2 x 2 GB),
dual channel
• 6 GB DDR3 SDRAM
(1 x 2 GB, 1 x 4 GB), dual channel
• 8 GB DDR3 SDRAM (2 x 4 GB),
dual channel
• 2 GB DDR3 SDRAM (2 x 1 GB),
dual channel
• 4 GB DDR3 SDRAM (2 x 2 GB),
dual channel
• 8 GB DDR3 SDRAM (2 x 4 GB),
dual channel

G

H

J

Swap media:
• CompactFlash drive, at front
• DVD±RW
• without swap medium

K

L

M

N

P

R

A
B
C
D

H

0
1
2
3
4
5
6
7

0
1
8

Bus module / hardware expansion
• Bus modules 3 slots: 2 x PCI;
1 x PCIe x16; without hardware
expansions
• Bus modules 3 slots: 2 x PCI;
1 x PCIe x16; DVI-VGA adapter
(1 x VGA) for onboard graphics
• Bus modules 3 slots: 2 x PCI;
1 x PCIe x16 assigned; + graphics
card PCIe x16, 2 x DP (2 x DVI-D
via 2 x DP-DVI adapters)
• Bus modules 3 slots: 2 x PCI;
1 x PCIe x16 assigned; + graphics
card PCIe x16, 2 x DP (2 x VGA via
2 x DP-VGA adapters)
• Bus modules 3 slots: 1 x PCI,
1 x PCIe x8 (4-lane); 1 x PCIe x16;
without HW expansions
• Bus modules 3 slots: 1 x PCI;
1 x PCIe x8 (4-lane); 1 x PCIe x16;
DVI-VGA adapter (1 x VGA) for onboard graphics
• Bus modules 3 slots: 1 x PCI;
1 x PCIe x8 (4-lane); 1 x PCIe x16
assigned; + graphics card
PCIe x16, 2 x DP (2x DVI-D via
2x DP-DVI adapters)
• Bus modules 3 slots: 1 x PCI;
1 x PCIe x8 (4-lane); 1 x PCIe x16
assigned; + graphics card
PCIe x16, 2 x DP (2x VGA via
2x DP-VGA adapters)

0

1

2

3

5

4

5

6

7

K
M
P

S
T
U

1)

For an up-to-date overview, see the SIMATIC PC online configurator at:
www.siemens.com/ipc-configurator

2)

Not in combination with Windows Server operating systems.

3)

Not in combination with graphics card, Windows XP, Windows 7 (32-bit),
without removable media.

Siemens ST 80 / ST PC · 2013

5/17

© Siemens AG 2013

PC-based Automation
Rack PC
SIMATIC IPC647C

■ Ordering data
SIMATIC IPC647C 1)
(continued)

Order No.

Operating system
(preinstalled and activated)
• Windows XP Professional, MUI
(Eng, Ger, Fr, It, Sp), SP3, 32-bit
• Windows 7 Ultimate, MUI (Eng,
Ger, Fr, It, Sp), 32-bit, SP1 included
• Windows 7 Ultimate, MUI (Eng,
Ger, Fr, It, Sp), 64-bit, SP1 included
• Windows Server 2003 R2 Standard
Edition incl. 5 clients, MUI (Eng, Fr,
Ger, It, Sp), SP2, 32-bit, SP2
• Windows Server 2008 Standard
Edition incl. 5 clients, MUI
(Eng, Fr, Ger, It, Sp), SP2, 32-bit
• Windows Server 2008 R2 Standard
Edition incl. 5 clients, MUI (Eng, Fr,
Ger, It, Sp), SP2, 64-bit, SP1 included
• Without operating system
Expansion (software)
• SIMATIC IPC DiagMonitor 4.3
included
• SIMATIC IPC Image Creator
software 3.2 included
• SIMATIC IPC DiagMonitor 4.3
and Image Creator Software 3.2
included
• Without software

5

Order No.

6AG4112- 1 7 7 7 7 - 7 7 7 7

Memory expansion
• 1 GB DDR3 1066 SDRAM, DIMM
• 2 GB DDR3 1066 SDRAM, DIMM
• 4 GB DDR3 1066 SDRAM, DIMM
• 1 GB DDR3 1066 SDRAM, DIMM,
ECC
• 2 GB DDR3 1066 SDRAM, DIMM,
ECC
• 4 GB DDR3 1066 SDRAM, DIMM,
ECC

B
E
F
N

P

Q

X

B
C

X

For an up-to-date overview, see the SIMATIC PC online configurator at:
www.siemens.com/ipc-configurator

0

1

2

6ES7648-2AJ40-0KA0
6ES7648-2AJ50-0KA0
6ES7648-2AJ60-0KA0
6ES7648-2AJ40-1KA0
6ES7648-2AJ50-1KA0
6ES7648-2AJ60-1KA0

Hard disk slide-in unit
for swap frame
SIMATIC PC accessories, slide-in
HDD swap frame, low-profile, for
3.5" hard disk, serial ATA / SAS
(without hard disk)

6ES7648-0EG00-1BA0

Filter mats
for SIMATIC IPC647C
(packing unit: 10 units)

A5E02396171

Power cable, straight, 3 m long
• Austria, Belgium, Finland, France,
Germany, Netherlands, Spain,
Sweden
• United Kingdom
• Switzerland
• USA
• Italy
• China

A

Power supply, with country-specific
cable:
• 100/240°V°AC industrial power
supply with Namur; power cable
for Europe
• 100/240 V AC industrial power
supply with Namur; power cable
for United Kingdom
• 100/240 V AC industrial power
supply with Namur; power cable
for Switzerland
• 100/240 V AC industrial power
supply with Namur; power cable
for USA
• 100/240 V AC industrial power
supply with Namur; power cable
for Italy
• 100/240 V AC industrial power
supply with Namur; power cable
for China
• 100/240 V AC redundant power
supply with Namur; without power
cable
1)

Accessories

6ES7900-0AA00-0XA0

6ES7900-0BA00-0XA0
6ES7900-0CA00-0XA0
6ES7900-0DA00-0XA0
6ES7900-0EA00-0XA0
6ES7900-0FA00-0XA0

USB retainer
for pin assignment of the internal
USB port

6ES7648-1AA00-0XK0

Expansion components

From page 5/153

Communication products

From page 5/186

RMOS real-time operating system

From page 5/146

3

4

5

6

Note:
Software Packages with SIMATIC WinCC flexible, WinCC RT
Advanced, SIMATIC WinCC, and SIMATIC WinAC RTX (F) can
be ordered together with the SIMATIC IPC at favorable prices.
More information under "Embedded bundles / Packages for
industrial PCs".

5/18

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
Rack PC
SIMATIC IPC647C

■ Dimensional drawings

■ More information

All dimensions in mm. For mounting cut-out see technical specifications.

Further information can be found in the Internet under:
http://www.siemens.com/simatic-pc

481.4

87.6

5.7

76.2

465

G_ST80_XX_00453

444.6

429.9

487.1

8.2

Technical data of the telescopic rails
Carrying capacity per pair, min.

30 kg

Full extension length, min.

470 mm

Rail thickness, max.

9.7 mm

Fixing screws

M5 x 6 mm

5

The fixing screws of the telescopic rails should not project more
than 5 mm into the enclosure.
The enclosure is prepared for the following telescopic rails:
• Rittal: Type 3659.180 for 600 mm cabinet /
Type RP 3659.190 for 800 mm cabinet

Siemens ST 80 / ST PC · 2013

5/19

© Siemens AG 2013

PC-based Automation
Rack PC
SIMATIC IPC847C

■ Overview

■ Technical specifications
SIMATIC IPC847C
General features
Design

19" rack, 4 HU, externally painted

Processor

• Intel Core i7-610E
( 2C/4T, 2.53 GHz, 4 MB Cache,
Turbo Boost, VT-d, iAMT, EM64T)
• Intel Core i5-520E
(2C/4T, 2.4 GHz, 3 MB cache,
Turbo Boost, VT-d, iAMT, EM64T)
• Intel Core i3-330E
(2C/4T, 2.13 GHz, 3 MB cache,
EM64T)

Chipset

Intel QM57

Main memory

•
•
•
•

Spare slots for expansions (all long)

• 7 x PCI
• 1 x PCI Express x16
• 3 x PCI Express x4

The SIMATIC IPC847C is a very robust, high-performance industrial PC in 19" rack design (4 HU) with excellent industrial
functionality.
It offers:
• Maximum expandability
• Extreme ruggedness
• Intel Core i technology

or
• 7 x PCI
• 1 x PCI Express x16
Graphics

1)

5

5/20

Siemens ST 80 / ST PC · 2013

from 1 GB DDR3 1066 SDRAM
Dual channel support
2 DIMM slots
Expandable up to 8 GB 1)

• Onboard Intel GMA HD graphics
controller integrated into processor; dynamic video memory; up to
2048 x 1536 pixels with 75 Hz
refresh rate and 16-bit colors
• PCI Express graphics card
(Dual Head: 2 x VGA or 2 x DVI-D
via display port adapter) in the
PCIe x16 slot; 256 MB; up to
2048 x 1536 pixels with 75 Hz
refresh rate and 32-bit colors
(optional)

Memory information:
In order to use a memory with more than 4 GB, a 64-bit operating system is
required. In the case of configurations with 4 GB, the visible memory can
be reduced to about 3.5 GB or less (with 32-bit operating systems).
In configurations with 8 GB, the visible memory can be reduced to about
7.5 GB or less.

© Siemens AG 2013

PC-based Automation
Rack PC
SIMATIC IPC847C

■ Technical specifications (continued)
SIMATIC IPC847C
Operating system

• without
• Preinstalled and activated /
supplied on restore DVD
• Windows XP Professional MUI,
32-bit
• Windows 7 Ultimate MUI,
32/64-bit
• Windows Server 2003 R2
incl. 5 client MUI, 32-bit
• Windows Server 2008 incl.
5 client MUI, 32-bit
• Windows Server 2008 R2
incl. 5 client MUI, 64-bit
MUI: Multi-language User Interface;
5 languages (English, French,
German, Italian, Spanish)
• Project-specific on request
• Linux 2)
• Other

Power supply

• 100 ... 240 V AC, 50 ... 60 Hz
with bridging of temporary power
failures in accordance with
NAMUR: max. 20 ms at
0.85% rated voltage
• Redundant 100 ... 240 V AC,
50 ... 60 Hz

SIMATIC IPC847C
Interfaces
PROFINET

3x RJ45 (CP 1616-compatible),
optional

PROFIBUS/MPI

12 Mbit/s (isolated, compatible
with CP 5611), optional

Ethernet

2 x 10/100/1000 Mbit/s
(RJ45, teaming-capable)

USB 2.0

• 2 x front (high current)
• 4 x rear (high current)
• 1 x internal (high current),
e.g. for USB dongle

Serial

• 9-pin COM1 (V.24)
• 9-pin COM2 (V.24)

Parallel

LPT1

VGA

1x

Keyboard

PS/2

Mouse

PS/2

Audio

1 x Line Out; 1 x Micro

Drives
Hard disks SATA 3.5" or SAS 3.5"

Installation in internal drive cage
• 250 GB
Can be installed in internal shock
and vibration-damped drive cage
(optional)
• 250 GB
• 500 GB
• 2 x 500 GB
• 500 GB RAID13),
(2 x 500 GB, mirror disks)
Installation in front drive cage in
swap frame
• 250 GB
• 2 x 500 GB
• 500 GB RAID13),
(2 x 500 GB, mirror disks),
"hot swap"
• 1 TB RAID53), (3 x 500 GB,
striping with parity), "hot swap"
• 1 TB RAID1, (2 x 1 TB, mirror
disks), "hot swap"; PCIe x8 RAID
controller in PCIe x16 slot
• 1.8 TB RAID5, (3 x 1 TB, striping
with parity), "hot swap"; controller
with zero-maintenance cache protection module in PCIe x16 slot
• 50 GB SATA solid-state drive
(SLC)

Solid-State Drive (SSD) (2.5" SATA)

Installed internally or front-mounted
in removable frame
50 GB (SLC), optional

DVD-ROM, 5.25", SATA

• 16 x (DVD media)
• 48 x (CD media)

DVD+/-R/RW, 5.25", SATA

• 16 x 16 x 12 x (DVD media)
• 48 x 32 x 48 x (CD media)

Floppy disk

-

Slots for drives

Front:
• 3 x 5.25" and 2 x 3.5"

5

Internal:
• 2 x 3.5" (in the optional,
vibration-damping drive cage)
2)

Suitable for specific LINUX versions in accordance with the specifications
of the Siemens manufacturer's declaration "Suitable for LINUX", see
http://www.siemens.com/simatic-pc/suited-for-linux
(LINUX is a trademark of Linus Torvald).

3)

SATA RAID controller on board in Intel chipset

Siemens ST 80 / ST PC · 2013

5/21

© Siemens AG 2013

PC-based Automation
Rack PC
SIMATIC IPC847C

■ Technical specifications (continued)
SIMATIC IPC847C
Monitoring functions

SIMATIC IPC847C
Ambient conditions

Basic functionality

Message locally
via DiagBase software

Degree of protection

IP41 at the front, IP20 at the rear
acc. to EN 60529

Temperature

• Overshoot/undershoot of permissible operating temperature range
• Messages can be evaluated by
the application program

Dust protection

With front door closed: G2 EN 779,
99% of particles > 0.5 mm are held
back

Protection class

Fan

• Speed monitoring
• 2 x enclosure fans
• 1 x fan power supply

Protection class I in accordance
with IEC 61140

Vibration load during operation

DIN EN 60068-2-6, 10 cycles

Watchdog

• Monitoring of program execution
• Monitoring time can be parameterized in software
• Restart can be parameterized in
the event of a fault
• Messages can be evaluated by
the application program

Monitoring functions via the network

SIMATIC PC DiagMonitor (optional)

Internal mounting of the hard disk
drives in optional, internal drive
cage:
• 10 ... 58 Hz: 0.0375 mm
• 58 ... 500 Hz: 5 m/s2
(approx. 0.5 g)
Permanently installed internal hard
disk drives:
• 10 ... 58 Hz: 0.019 mm
• 58 ... 500 Hz: 3 m/s2
(approx. 0.3 g)

Remote monitoring capability for:
• Watchdog
• Temperature
• Fan speed
• Hard disk monitoring (SMART)
• System/Ethernet monitoring
(Heart Beat)
Communication:
• Ethernet interface
(SNMP protocol)
• OPC for integration
in SIMATIC software
• Configuration of
client/server architectures
• Structure of log files
Front LEDs

5

5/22

• POWER (internal power supply
unit, PC switched on)
• HARDDISK (access to hard disk)
• ETHERNET1
(Ethernet status, "Heartbeat")
• ETHERNET2 (Ethernet status,
"Heartbeat")
• PN / MPI/DP
(PROFINET/PROFIBUS status)
• WATCHDOG
(ready/fault indication)
• TEMP (temperature status)
• FAN (fan speed monitoring)
• HDD1 ALARM (hard disk alarm in
conjunction with RAID and monitoring software)
• HDD2 ALARM (hard disk alarm in
conjunction with RAID and monitoring software)
• HDD3 ALARM (hard disk alarm in
conjunction with RAID and monitoring software)

Siemens ST 80 / ST PC · 2013

Note:
There are limitations when
DVD+/-RW and HDD are operated
in a swap frame
Shock loading during operation

DIN EN 60068-2-27,
IEC 60068-2-29
Internal mounting of the hard disk
drives in optional, internal drive
cage:
• Half-sine: 50 m/s2, 30 ms
(approx. 5 g), 100 shocks
per axis
• Permanently installed internal
hard disk drives: 30 m/s2,
30 ms (approx. 3 g)
Note:
There are limitations when
DVD+/-RW and HDD are operated
in a swap frame

© Siemens AG 2013

PC-based Automation
Rack PC
SIMATIC IPC847C

■ Technical specifications (continued)
SIMATIC IPC847C
Electromagnetic compatibility (EMC)
Emitted interference (AC)

EN 61000-6-3 FCC Class A
EN 61000-3-2 Class D and
EN 61000-3-3

Immunity to conducted interference
on the supply lines

± 2 kV (IEC 61000-4-4, burst)
± 1 kV
(IEC 61000-4-5, symm. surge)
± 2 kV
(IEC 61000-4-5, asymm. surge)

Immunity to interference on signal lines

± 1 kV (IEC 61000-4-4, burst,
length < 30 m)
± 2 kV (IEC 61000-4-4, symm.
surge, length > 30 m)
± 2 kV (IEC 61000-4-5, asymm.
surge, length > 30 m)

Immunity to static discharge

±6 kV, contact discharge
(IEC 61000-4-2)
±8 kV, air discharge
(IEC 61000-4-2)

Immunity to high radio frequency
interference

• 1 V/m 80% AM; 2-2.7 GHz
(IEC 61000-4-3)
• 10 V/m 80% AM; 80 MHz to
1 GHz and 1.4 GHz and 2 GHz
(IEC 61000-4-3);
• 10 V, 10 kHz to 80 MHz
(IEC 61000-4-6)

Immunity to magnetic fields

100 A/m, 50/60 Hz (IEC 61000-4-8)

Ambient temperature
during operation

5 ... 50 °C

Relative operating humidity

5 ... 80% at 25 °C
(no condensation)

Note:
There are limitations when using
DVD-ROM / DVD+/-RW and SAS
HDD in swap frames

5

Approvals and safety regulations
Safety regulations

IEC 60950-1 Second Edition,
EN 60950-1:2006,
UL 60950-1 Second Edition
CSA C22.2 No 60950-1-07
Second Edition

Approvals

cULus 60950-1 Second Edition,
KCC

CE mark

• Emitted interference:
EN 61000-6-3:2007
• Noise immunity:
EN 61000-6-2:2005

Dimensions and weights
Mounting dimensions
(W x H x D, in mm)

430 x 177 x 448

Note regarding SIMATIC PC operating system licenses
The accompanying operating system license is only valid for
installation on the respective supplied SIMATIC IPC. Installation
can only be performed on these SIMATIC systems in accordance with Microsoft OEM licensing regulations.

Siemens ST 80 / ST PC · 2013

5/23

© Siemens AG 2013

PC-based Automation
Rack PC
SIMATIC IPC847C

■ Ordering data
SIMATIC IPC847C

Order No.
1)

Order No.

6AG4114- 1 7 7 7 7 - 7 7 7 7

Interfaces: 2 x 10/100/1000 Mbps
Ethernet (RJ45);
1 x graphic (DVI-I); 2 x COM;
1 x LPT; 2 x PS/2;
4 x USB 2.0 at rear,
2 x USB 2.0 at front,
1x USB 2.0 internal; audio;
temperature and fan monitoring,
watchdog;

5

Processor, motherboard:
• Core i3-330E
(2C/4T, 2.13 GHz, 3 MB cache),
motherboard without fieldbus
• Core i3-330E
(2C/4T, 2.13 GHz, 3 MB cache),
motherboard with PROFIBUS/MPI
• Core i3-330E
(2C/4T; 2.13 GHz, 3 MB cache),
motherboard with PROFINET
(3 x RJ45, CP 1616-compatible) 2)
• Core i5-520E
(2C/4T, 2.4 GHz, 3 MB cache,
TB, iAMT, VT), motherboard
without fieldbus
• Core i5-520E
(2C/4T, 2.4 GHz, 3 MB cache,
TB, iAMT, VT), motherboard
with PROFIBUS/MPI
• Core i5-520E
(2C/4T; 2.4 GHz, 3 MB cache,
TB, iAMT, VT), motherboard
with PROFINET (3 x RJ45,
CP 1616-compatible) 2)
• Core i7-610E
(2C/4T, 2.53 GHz, 4 MB cache,
TB, iAMT, VT), motherboard
without field bus
• Core i7-610E (2C/4T, 2.53 GHz,
4 MB cache, TB, iAMT, VT),
motherboard with PROFIBUS/MPI
• Core i7-610E
(2C/4T; 2.53 GHz, 4 MB cache,
TB, iAMT, VT), motherboard
with PROFINET (3 x RJ45,
CP 1616-compatible) 2)

5/24

Siemens ST 80 / ST PC · 2013

G

H

J

K

L

M

N

P

R

SIMATIC IPC847C
(continued)

1)

Hard disks:
• 250 GB HDD SATA; 0.5 g vibration,
5 g shock, internal
• 500 GB HDD SATA; 0.5 g vibration,
5 g shock, internal
• 2 x 500 GB HDD SATA; 0.5 g vibration, 5 g shock, internal
• RAID1 500 GB (2 x 500 GB HDD
SATA, mirror disks); 0.5 g vibration,
5 g shock, internal
• 250 GB HDD SATA; 0.3 g vibration,
3 g shock, internal
• 250 GB HDD SATA in swap frame;
front
• 500 GB HDD SATA in swap frame;
front
• 2 x 500 GB HDD SATA in swap
frame; front
• RAID1 500 GB
(2 x 500 GB HDD SATA) in swap
frame, for hot swapping; front
• RAID5 1 TB
(3 x 500 GB HDD SATA) in swap
frame, for hot swapping; front
• 50 GB SSD (SLC) SATA, internal
• 50 GB SSD (SLC) SATA in swap
frame; front
• RAID1 1 TB (2 x 1 TB HDD SAS)
in swap frame, for hot-swapping,
front; PCIe x8 RAID controller with
zero-maintenance cache protection module in PCIe x16 slot 3)
• RAID5 1.8 TB (3 x 1 TB HDD SAS)
in swap frame, for hot-swapping,
front; PCIe x8 RAID controller with
zero-maintenance cache protection module in PCIe x16 slot 3)
Memory configuration:
• 1 GB DDR3 SDRAM
(1 x 1 GB), single channel
• 2 GB DDR3 SDRAM
(1 x 2 GB), single channel
• 4 GB DDR3 SDRAM
(2 x 2 GB), dual channel
• 6 GB DDR3 SDRAM
(1 x 2 GB, 1 x 4 GB), dual channel
• 8 GB DDR3 SDRAM
(2 x 4 GB), dual channel
• 2 GB DDR3 SDRAM
(2 x 1 GB), dual channel
• 4 GB DDR3 SDRAM
(2 x 2 GB), dual channel
• 8 GB DDR3 SDRAM
(2 x 4 GB), dual channel

6AG4114- 1 7 7 7 7 - 7 7 7 7

A
B
C
D

G
H
K
M
P

R

S
T
U

V

0
1
2
3
4
5
6
7

1)

For an up-to-date overview, see the SIMATIC PC online configurator at:
www.siemens.com/ipc-configurator

2)

Not in combination with Windows Server 2008 R2, Windows Server 2008
and Windows Server 2003 R2

3)

Not in combination with graphics card, Windows XP, Windows 7 (32-bit),
without removable media.

© Siemens AG 2013

PC-based Automation
Rack PC
SIMATIC IPC847C

■ Ordering data
SIMATIC IPC847C 1)
(continued)
Swap media:
• DVD-ROM
• DVD+/-RW
• Without swap medium
Bus module / hardware expansion
• Bus module, 8 slots:
7 x PCI, 1 x PCIe x16;
without hardware expansions
• Bus module, 8 slots:
7 x PCI; 1x PCIe x16;
DVI-VGA adapter (1 x VGA)
for onboard graphics
• Bus module, 8 slots:
7x PCI; 1x PCIe x16 assigned;
+ graphics card PCIe x16, 2 x DP
(2x DVI-D via 2x DP-DVI adapters)
• Bus module, 8 slots:
7x PCI; 1x PCIe x16 assigned;
+ graphics card PCIe x16, 2 x DP
(2x VGA via 2x DP-VGA adapters)
• Bus module, 11 slots:
7 x PCI, 1 x PCIe x16, 3 x PCIe x4;
without hardware expansions
• Bus module, 11 slots:
7x PCI, 1x PCIe x16, 3x PCIe x4;
+ DVI-VGA adapter (VGA) for
onboard graphics
• Bus module, 11 slots:
7x PCI; 1x PCIe x16 assigned,
3x PCIe x4; + graphics card
PCIe x16, 2 x DP (2x DVI-D via
2x DP-DVI adapters)
• Bus module, 11 slots:
7x PCI; 1x PCIe x16 assigned;
3x PCIe x4; + graphics card
PCIe x16, 2x DP (2x VGA via
2x DP-VGA adapters)

Order No.

Order No.

6AG4114- 1 7 7 7 7 - 7 7 7 7

1
2
8
0

1

2

3

4

5

6

7

SIMATIC IPC847C 1)
(continued)

6AG4114- 1 7 7 7 7 - 7 7 7 7

Operating system
(preinstalled and activated)
• Windows XP Professional, MUI
(Eng, Ger, Fr, It, Sp), 32-bit, SP3
• Windows 7 Ultimate, MUI (Eng,
Ger, Fr, It, Sp), 32-bit, SP1 included
• Windows 7 Ultimate, MUI (Eng,
Ger, Fr, It, Sp), 64-bit, SP1 included
• Windows Server 2003 R2 Standard
Edition incl. 5 clients, MUI
(Eng, Fr, Ger, It, Sp), 32-bit, SP2
• Windows Server 2008 Standard
Edition incl. 5 clients, MUI
(Eng, Ger, Fr, It, Sp), 32-bit, SP2
• Windows Server 2008 R2 Standard
Edition incl. 5 clients, MUI
(Eng, Ger, Fr, It, Sp), 64-bit, SP1
enclosed
• Without operating system
Software expansion
• SIMATIC IPC DiagMonitor 4.3
included
• SIMATIC IPC Image Creator
software 3.2 included
• SIMATIC IPC DiagMonitor 4.3 &
Image Creator software 3.2
included
• Without software
Power supply,
country-specific cable
• 100/240 V AC industrial power
supply with Namur; power cable
for Europe
• 100/240 V AC industrial power
supply with Namur; power cable
for United Kingdom
• 100/240 V AC industrial power
supply with Namur; power cable
for Switzerland
• 100/240 V AC industrial power
supply with Namur; power cable
for USA
• 100/240 V AC industrial power
supply with Namur; power cable
for Italy
• 100/240 V AC industrial power
supply with Namur; power cable
for China
• 100/240 V AC industrial redundant
power supply unit with Namur;
without power cable
1)

B
E
F
N

P

Q

X
A
B
C

X

0

1

2

3

4

5

6

For an up-to-date overview, see the SIMATIC PC online configurator at:
http://www.siemens.com/ipc-configurator

Siemens ST 80 / ST PC · 2013

5/25

5

© Siemens AG 2013

PC-based Automation
Rack PC
SIMATIC IPC847C

■ Ordering data

Order No.

Order No.

Accessories
Memory expansion
• 1 GB DDR3 1066 SDRAM, DIMM
• 2 GB DDR3 1066 SDRAM, DIMM
• 4 GB DDR3 1066 SDRAM, DIMM
• 1 GB DDR3 1066 SDRAM, DIMM,
ECC
• 2 GB DDR3 1066 SDRAM, DIMM,
ECC
• 4 GB DDR3 1066 SDRAM, DIMM,
ECC

Power cable, straight, 3 m long
• Austria, Belgium, Finland, France,
Germany, Netherlands, Spain,
Sweden
• United Kingdom
• Switzerland
• USA
• Italy
• China

6ES7648-2AJ40-0KA0
6ES7648-2AJ50-0KA0
6ES7648-2AJ60-0KA0
6ES7648-2AJ40-1KA0
6ES7648-2AJ50-1KA0
6ES7648-2AJ60-1KA0

Tower Kit
for converting the computer into an
industrial tower PC

6ES7648-0EG00-1BA0

Hard disk slide-in unit
for swap frame
SIMATIC PC accessories,
slide-in unit for low-profile HDD
swap frame, for 3.5" hard disk,
SATA / SAS (without hard disk)
Filter mats
For Rack PC 847B and IPC847C
Packing unit 10 units

A5E01064980

6ES7900-0AA00-0XA0

6ES7900-0BA00-0XA0
6ES7900-0CA00-0XA0
6ES7900-0DA00-0XA0
6ES7900-0EA00-0XA0
6ES7900-0FA00-0XA0
6ES7648-1AA00-0XD0

Retainer
for pin assignment of the internal
USB port

6ES7648-1AA00-0XK0

Expansion components

From page 5/153

Communication products

From page 5/186

RMOS real-time operating system

From page 5/146

Note:
Software Packages with SIMATIC WinCC flexible, WinCC RT
Advanced, SIMATIC WinCC, and SIMATIC WinAC RTX (F) can
be ordered together with the SIMATIC IPC at favorable prices.
More information under "Embedded Bundles / Packages for
industrial PCs".

■ Dimensional drawings
All dimensions in mm. For mounting cut-out see technical specifications.

101.6

5

176.5

481.4
465.1

*B67B;;B

492

448

Further information can be found in the Internet under:

Siemens ST 80 / ST PC · 2013

470 mm

Rail thickness, max.

9.7 mm

Fixing screws

M5 x 6 mm

The enclosure is prepared for the following telescopic rails:
• Rittal: Type 3659.180 for 600 mm cabinet /
Type RP 3659.190 for 800 mm cabinet
• Schroff: Type 20110-072

■ More information

5/26

30 kg

Full extension length, min.

The fixing screws of the telescopic rails should not project more
than 5 mm into the enclosure.

430

http://www.siemens.com/simatic-pc

Technical data of the telescopic rails
Carrying capacity per pair, min.

© Siemens AG 2013

PC-based Automation
Box PC
Box PC

■ Overview

SIMATIC Box PCs provide mechanical engineers, plant
engineers and control cabinet makers with particularly rugged
industrial PC systems for use in powerful yet compact applications.
The following device classes are available for various requirements:
• SIMATIC IPC227 (Nanobox PC):
The compact embedded IPC – maintenance-free and
dust-proof with versatile mounting
• SIMATIC IPC427 (Microbox PC):
The powerful embedded IPC – maintenance-free with
versatile configuration
• SIMATIC IPC627/IPC827 (Box PC):
The high-end IPC – with maximum performance, functional
scope, and expansion capability

Shared industrial functionality:
• Extreme compactness
• Certification for global marketing
• System-tested with SIMATIC components
• High vibration/shock load during operation
• Wide operational temperature range
• Robust data storage with CompactFlash/CFast or Solid-State
Drive (SSD)
• Integrated PROFIBUS or PROFIBUS/MPI interface (optional)
• Varied mounting possibilities for flexibility with installation
• Designed for 24-hour continuous operation
• Integrated parameterizable monitoring functions
(temperature, fan, watchdog)
• High service friendliness
• Operating system preinstalled and activated for fast startup
• Motherboard developed and manufactured by Siemens
• Availability for 3 to 6 years
• Repairs and spare parts service for 5 years
• High continuity of the components/design
• Installation and software compatible with predecessor model
• Long-term availability of PC components from the Intel
embedded line
SIMATIC IPC227 (Nanobox PC):
The compact embedded IPC – maintenance-free and dustproof with versatile mounting
• Maximum compactness with approx. 1 liter enclosure volume
with integrated industrial power supply for minimum space
requirements in the control cabinet
• Maximum flexibility thanks four mounting options and interfaces on one side suitable for every installation situation
• Optimum variety of interfaces due to a large number of
integrated interfaces such as selectable serial ports
(RS 232/RS 485/CAN) and 2 x teaming-capable Gigabit LAN
• Maximum industrial functionality due to closed enclosure for
optimum dust protection and non-volatile retentive memory
• Further device options for optimum adaptation to the
application with additional PCIe slot or RS 232 interfaces
or digital I/O

Siemens ST 80 / ST PC · 2013

5/27

5

© Siemens AG 2013

PC-based Automation
Box PC
Box PC

■ Overview (continued)
SIMATIC IPC427 (Microbox PC):
The powerful embedded IPC – maintenance-free with
versatile configuration
• Fan-free operation
• High performance with maximum compactness and
ruggedness for direct installation in the machine
• Optimized for embedded applications
• Flexibility expandable using one or two PCIe I/O cards
(optional)
• Flexible installation options due to DIN rail/wall/front upright
mounting, even outside a control cabinet
• NVRAM for retentive data storage (optional)

SIMATIC IPC627/IPC827 (Box PC):
The high-end IPC – with maximum performance, functional
scope, and expansion capability
• Maximum system performance for complex measuring,
control and visualization tasks
• High flexibility with expansion slots and integral interfaces
• Flexible, space-saving installation with mounting brackets or
portrait assembly kits
• Rugged design for direct installation in the machine
• RAID1 controller onboard
• Maximum processor performance up to ambient temperature
of 55 °C
• High system availability
• Battery-backed SRAM as memory for WinAC data
• 2 x 7-segment display and 2 signal LEDs
(freely programmable)

SIMATIC IPC227D
(Nanobox PC)

SIMATIC IPC427D
(Microbox PC)

SIMATIC IPC427C
(Microbox PC)

SIMATIC IPC627C
(Box PC)

SIMATIC IPC827C
(Box PC)

Rail or wall mounting

•

•

•

-

-

Wall or portrait mounting

• Also: Side mounting

•

•

•

•

Processor

• Intel Atom E620
600 MHz
• Intel Atom E640
1.0 GHz
• Intel Atom E660
1.3 GHz

• Intel Core i73517UE, 1.7 GHz,
4 MB SLC
• Intel Core i33217UE, 1.6 GHz,
3 MB SLC
• Intel Celeron 827E
1.4 GHz, 1.5 MB
SLC

• Intel Core2 Duo
1.2 GHz, 800 MHz
FSB, 3 MB SLC
• Intel Core2 Solo
1.2 GHz, 800 MHz
FSB, 3 MB SLC
• Intel Celeron M
1.2 GHz, 800 MHz
FSB, 1 MB SLC

• Intel Core i7-620E,
2.53 GHz, 2 cores,
4 threads, 4 MB
cache, TB, HT, VT-x,
VT-d
• Intel Core i3-330E,
2.13 GHz, 2 cores,
4 threads, 3 MB
cache, HT, VT-x
• Intel Celeron P4505,
1.86 GHz, 2 cores,
2 MB cache

• Intel Core i7-620E,
2.53 GHz, 2 cores,
4 threads, TB, HT,
VT-x, VT-d, AMT 4
MB cache
• Intel Core i3-330E,
2.13 GHz, 2 cores,
4 threads, HT, VT-x,
3 MB cache
• Intel Celeron P4505,
1.86 GHz, 2 cores,
2 MB cache

Main memory

512 MB, 1 GB, 2 GB

1 GB, 2 GB, 4 GB,
8 GB

1 GB, 2 GB, 4 GB

1 GB, expandable up
to 8 GB,
optional ECC

1 GB, expandable up
to 8 GB,
optional ECC

Static RAM

512 KB

512 KB

2 MB

2 MB

2 MB

Free slots for expansions

1 x PCIe with PCIe
enclosure option

Up to 2 x PCIe
(enclosure option)

Up to 3 x PCI-104
(with expansion frame)

2 x PCI or
1 x PCI-Express x16 /
1 x PCI
(175 mm / 265 mm)

3 x PCI
(290/290/240 mm),
1 PCI-Express x
(185 mm)
1 x PCI-Express x16
(240 mm)

Graphics

Onboard

Onboard

Onboard

Onboard

Onboard

Design

General features

5

5/28

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
Box PC
Box PC

■ Overview (continued)
SIMATIC IPC227D
(Nanobox PC)

SIMATIC IPC427D
(Microbox PC)

SIMATIC IPC427C
(Microbox PC)

SIMATIC IPC627C
(Box PC)

SIMATIC IPC827C
(Box PC)

Operating system
without

•

•

•

•

•

Preinstalled and activated / supplied
on restore CD

• Windows Embedded Standard 2009
(CF card ≥ 2 GB,
SSD, hard disk)
• Windows XP Professional MUI (SSD,
hard disk)
• Windows Embedded Standard 7,
32 bit
(CF card ≥ 4 GB,
SSD, hard disk)
• Windows 7 Ultimate
MUI, 32 bit (SSD,
hard disk)

• Windows 7
Ultimate MUI
• Windows Embedded Standard 7 in
combination with
CF card ≥ 4 GB,
solid-state drive,
or hard drive

• Windows Embedded
Standard 2009, in
combination with CF
card ≥ 2 GB, solidstate drive, or hard
drive
• Windows XP Professional Multi-Language; in combination
with solid-state drive
or hard drive
• Windows 7 Ultimate
MUI
• Windows Embedded
Standard 7

• Windows XP
Professional MUI
• Windows 7 Ultimate
32-bit MUI
• Windows 7 Ultimate
64-bit MUI
• Windows Embedded Standard 2009
English on 8 GB
CompactFlash

• Windows XP
Professional MUI
• Windows 7 Ultimate
32-bit MUI
• Windows 7 Ultimate
64-bit MUI
• Windows Embedded Standard 2009
English on 8 GB
CompactFlash

Order separately

RMOS3 V3.50

RMOS3 V3.50

RMOS3 V3.50

RMOS3 V3.50

RMOS3 V3.50

Project-specific on request

• Linux 1)
• Other

• Linux 1)
• Other

• Linux 1)
• Other

• Linux 1)
• Other

• Linux 1)
• Other

PROFINET onboard

-

3 x RJ45 (CP 1616
compatible)
onboard, optional

3 x RJ45 (CP 1616
compatible) onboard,
optional

3 x RJ45 (CP 1616
compatible) onboard,
optional

3 x RJ45 (CP 1616
compatible) onboard,
optional

PROFIBUS/MPI

-

12 Mbps (compatible with CP 5622),
optional

12 Mbps (CP 5611compatible), optional

12 Mbps (CP 5611compatible) onboard,
optional

12 Mbps (CP 5611compatible) onboard,
optional

Ethernet

2 x 10/100/
1000 Mbps

2 x 10/100/
1000 Mbps

2 x 10/100/1000 Mbps

2 x 10/100/
1000 Mbps

1 x 10/100/
1000 Mbps

USB 2.0 (high current)

4x

4 x USB 3.0

4x

4x

4x

VGA, LVDS, DVI, DPP

1 x DVI-D

• 1 x DVI-I
(DVI and VGA)
• 1 x DisplayPort

1 x DVI-I
(DVI and VGA)

1 x DVI-I
(DVI and VGA)

1 x DVI-I
(DVI and VGA)

Hard disks

1 x 2.5" (optional)

1 x 2.5" (optional)

1 x 2.5" (optional)

• 1 x 3.5"
• 2 x 2.5"
• RAID1/2 x 2.5"

• 1 x 3.5"
• 2 x 2.5"
• RAID1/2 x 2.5"

Solid-state drive

1 x 2.5" SATA
(optional)

1 x 2.5" SATA
(optional)

1 x 2.5" SATA (optional)

1 x 2.5" SATA
(optional)

1 x 2.5" SATA
(optional)

FlashDrive

1 x CF externally
accessible

• 1 x CFast externally accessible
• 1 x CFast internal,
in place of HDD,
SSD (optional)

• 1 x CF externally
accessible
• 1 x CF internal, in
place of HDD, SSD
(optional)

• 1 x CF at the front,
externally accessible
• 1 x CF internal, in
place of HDD
(optional)

1 x CF at the front,
externally accessible

Optical drives

-

-

-

DVD R/W

DVD R/W

Vibration/shock load during operation

1 g / 15 g
(with FlashDrive)

1 g / 15 g
(with FlashDrive)

1 g / 15 g
(with FlashDrive)

1g/5g

1g/5g

Ambient temperature
during operation

0 °C … 50 °C
(with FlashDrive)
0 °C … 40 °C
(with hard disk)

With maximum
configuration:
0 ... 50/55 ºC
(with FlashDrive)

With maximum
configuration:
0 ... 50/55 ºC
(with FlashDrive)

With maximum
configuration:
5 ... 45 °C

With maximum
configuration:
5 ... 45 °C

5 ... 40 ºC
(with hard disk)

5 ... 40 ºC
(with hard disk)

5 ... 50/55 °C
(with 20/10 W load on
PCI/PCI-Express bus)

5 ... 50/55 °C
(with 20/10 W load on
PCI/PCI-Express bus)

Interfaces

Drives

Ambient conditions

• Available
- Not available

1)

Suitable for specific Linux versions in accordance with the specifications of
the Siemens manufacturer's declaration "Suitable for Linux", see
http://www.siemens.com/simatic-pc/suited-for-linux
(Linux is a trademark of Linus Torvald).

■ More information
Further information can be found on the Internet at:
http://www.siemens.com/simatic-pc
Information material can be ordered or downloaded from the
Internet:
http://www.siemens.com/simatic/printmaterial

Siemens ST 80 / ST PC · 2013

5/29

5

© Siemens AG 2013

PC-based Automation
Box PC
SIMATIC IPC227D

■ Overview

■ Technical specifications
SIMATIC IPC227D
General features

5

SIMATIC IPC227D (Nanobox PC):
The compact embedded IPC – maintenance-free and
dust-proof with versatile mounting
• Maximum compactness with approx. 1 liter enclosure volume
or more with integrated industrial power supply for minimum
space requirements in the control cabinet
• Maximum flexibility thanks four mounting options and interfaces on one side suitable for every installation situation
• Optimum variety of interfaces due to a large number of
integrated interfaces such as a selectable serial port
(RS 232/RS 485/CAN) and 2 x teaming-capable Gigabit LAN
• Maximum industrial functionality due to closed enclosure for
optimum dust protection and non-volatile retentive memory
• Further device options for optimum adaptation to the application with additional PCIe slot or R S232 interfaces or
digital I/O

Design

Rail, wall, portrait or side mounting

Processor

• Intel Atom E620 600 MHz,
512 MB RAM
• Intel Atom E640 1.0 GHz,
1 GB RAM
• Intel Atom E660 1.3 GHz,
2 GB RAM

Chipset

Intel Controller Hub EG20T

Buffered MRAM

optional, 512 KB, of which 128 KB
can be written within the buffer time

Free slots for expansions

Optional PCIe expansion slot

Graphics

• Integrated into Intel Atom CPU E6xx
• 8 to 256 MB (shared memory),
1920 x 1200, 60 Hz, 32-bit colors

Operating system

• Without
• Windows Embedded Standard
2009 preinstalled, in combination
with CF card or solid-state drive or
hard drive (optional)
• Windows XP Professional MUI preinstalled (in combination with solidstate drive or hard drive; MUI: Multi
Language User Interface) (optional)
• Windows Embedded Standard 7,
32-bit, preinstalled, in combination
with CF card or solid-state drive or
hard drive (optional)
• Windows 7 Ultimate MUI 32 bit preinstalled (in combination with solidstate drive or hard drive; MUI: Multi
Language User Interface) (optional)
• Linux 1)
(project-specific, on request)
• RMOS (project-specific on request)
• Others on request project-specifically

Design

Rail, wall, portrait or side mounting

Power supply

• 24 V DC (20.4 V ... 28.8 V)
• Isolated
• With buffering of temporary power
failures: max. 10 ms
• Line side switch
• With power failure indication by
means of Power Fail signal

1)

5/30

Siemens ST 80 / ST PC · 2013

Suitable for specific LINUX versions in accordance with the specifications
of the Siemens manufacturer's declaration "Suitable for LINUX", see
http://www.siemens.com/simatic-pc/suited-for-linux
(LINUX is a trademark of Linus Torvald).

© Siemens AG 2013

PC-based Automation
Box PC
SIMATIC IPC227D

■ Technical specifications (continued)
SIMATIC IPC227D
Drives
Flash drive

SIMATIC IPC227D
Monitoring functions

Optional; replaceable, accessible,
diagnosable
• 2 GB
• 4 GB
• 8 GB
• 16 GB

• Processor temperature
• Motherboard

Temperature

Messages can be evaluated by the
application program

Solid-state drive (SSD)

Optional
• 50 GB SATA, High Endurance, 2.5"
• 80 GB SATA, Standard, 2.5"

• Monitoring of program execution
• Monitoring time can be parameterized in software
• Can be parameterized for a fault or
restart

Hard disk

Optional
• 250 GB SATA

Messages can be evaluated by the
application program

CD-ROM

Via USB
(not included in scope of delivery)

DVD-RW

Via USB
(not included in scope of delivery)

Floppy disk

Via USB
(not included in scope of delivery)

Watchdog

Monitoring functions via the network

Remote monitoring capability for:
• Watchdog
• Temperature
• Mass memory monitoring (SMART)
• System/Ethernet monitoring
(Heart Beat)
• Runtime meter

Interfaces
PROFINET

PROFINET RT via Standard Ethernet
controller

PROFIBUS/MPI

-

Ethernet

• 2 x 10/100/1000 Mbps (RJ 45)
• Two independent Intel Controllers:
Intel 82574L / Intel Controller Hub
EG20T
• With teaming function

USB

V2.0: 4 x

Serial

COM1 (V.24), optional COM2-4

DVI-I

1 x DVI-D

Keyboard

Via USB (not included in scope of
delivery)

Mouse

Via USB (not included in scope of
delivery)

• DiagBase
• SIMATIC IPC DiagMonitor

Communication:
• Ethernet interface (SNMP protocol)
• OPC for integration in
SIMATIC software
• Configuration of client/server architectures
• Structure of log files
Ambient conditions
Degree of protection to EN 60529
(front/rear)

IP40

Vibration load during operation

Devices without hard disk:
• Requirements according to:
IEC 61131-2
• Tested according to:
IEC 60068-2-6, Test Fc
• 10-58: 0.0375 mm
• 58-200: 9.8 m/s2
• 10 x /axis
Devices with hard disk:
• Requirements according to:
IEC 61131-2
• Tested according to:
IEC 60068-2-6, Test Fc
• 10-58: 0.0375 mm
• 58-200: 4.9 m/s2
• 10 x /axis

Shock loading during operation

Devices without hard disk:
• Requirements according to:
IEC 61131-2
• Tested according to:
IEC 60068-2-27, Test Ea
• 150 m/s2, 30 ms shock duration
Devices with hard disk:
• Requirements according to:
IEC 61131-2
• Tested according to:
IEC 60068-2-27, Test Ea
50 m/s2, 30 ms shock duration

Moist heat

With CompactFlash card/SSD: 95 %
With hard disk: 80 %

Ambient temperature
during operation

0 °C up to 50 °C

Siemens ST 80 / ST PC · 2013

5/31

5

© Siemens AG 2013

PC-based Automation
Box PC
SIMATIC IPC227D

■ Technical specifications (continued)
SIMATIC IPC227D
Electromagnetic compatibility
(EMC)

SIMATIC IPC227D
Approvals

Emitted interference

EN 55022 Class B

Interference immunity, burst

EN 61000-6-2 or IEC 61131-2:
• 2 kV - tested acc. to IEC 61000-4-4
• 1 kV symmetrical / 2 kV asymmetrical - tested acc. to IEC 61000-4-5

Interference immunity, surge

• 1 kV to IEC 61000-4-5; symmetrical
• 2 kV to IEC 61000-4-5; asymmetrical

Marine approval
Only for configurations with
CompactFlash or SSD memory

•
•
•
•
•
•

GL – Germanische Lloyd
BV – Bureau Veritas
LR – Lloyds Register of Shipping
ABS – American Bureau of Shipping
DNV – Det Norske Veritas
NKK – Nippon Kaiji Kyokai

Device versions
Basic version

Width x Height x Depth:
approx. 191 x 100 x 60 mm

ESD interference immunity

According to NAMUR Recommendation NE 21 and EN 61000-6-2:
• 6 kV contact discharge - tested acc.
to IEC 61000-4-2
• 8 kV air discharge - tested acc. to
IEC 61000-4-2

COM

• 3 additional, integrated
serial interfaces
(COM2-4);
only sending/receiving of data
• Width x Height x Depth:
approx. 191 x 100 x 89 mm

Immunity to high radio frequency
interference

According to EN 61000-6-2 or
IEC 61131-2:
• Interference immunity 80 ... 1000
MHz: 10 V/m with 80% AM (1 kHz);
tested acc. to IEC 61000-4-3;
• 1.4 GHz ... 2 Hz: 10 V/m with 50%
pulse modulation; tested according
to IEC 61000-4-3

IO

• 4 digital inputs/outputs each, 24 V,
integrated
• Width x Height x Depth:
approx. 191 x 100 x 89 mm

PCIe

• 1 PCIe (x1) slot, integrated
• Width x Height x Depth:
approx. 191 x 187 x 89 mm

Immunity to high-frequency current
feed

Acc. to NAMUR Recommendation
NE 21 and EN 61000-6-2 or
IEC 61131-2:
• 10 kHz ... 80 MHz: 10 V
with 80% AM (1 kHz)
tested acc. to IEC 61000-4-6

Immunity to magnetic fields

Acc. to NAMUR Recommendation
NE 21 and EN 61000-6-2
or IEC 61131-2:
• 50/60 Hz; 100 A/m rms value tested acc. to IEC 61000-4-8

Release for individual order variants: See releases in the
ordering procedure.

5

5/32

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
Box PC
SIMATIC IPC227D

■ Ordering data
SIMATIC IPC227D

Order No.

Order No.

6ES7647- 8 A 7 7 7 - 7 7 7 7

Atom E620 (600 MHz),
512 MB RAM,
without drive, with CF slot,
COM1: RS232, without operating
system,
device version: Base,
DIN rail,
1 x DVI-D graphics interface
2 x 10/100/1000 Mbps Ethernet
RJ45
4 x USB V2.0 (high current)
CompactFlash slot
24 V DC industrial power supply
Processors / memory configuration /
NVRAM
• Atom E620 (600 MHz), 512 MB
RAM
• Atom E620 (600 MHz), 512 MB
RAM, NVRAM
• Atom E640 (1.0 GHz), 1 GB RAM
• Atom E640 (1.0 GHz), 1 GB RAM,
NVRAM
• Atom E660 (1.3 GHz), 2 GB RAM
• Atom E660 (1.3 GHz), 2 GB RAM,
NVRAM
Drives
• Without drive, with CF slot
• 250 GB HDD SATA
• 50 GB Solid-State Drive SATA
(High Endurance)
• 80 GB Solid-State Drive SATA
(Standard)
• 2 GB SIMATIC IPC CompactFlash
• 4 GB SIMATIC IPC CompactFlash
• 8 GB SIMATIC IPC CompactFlash
• 16 GB SIMATIC IPC CompactFlash
COM interface
• COM1: RS232
• COM1: RS485
• COM1: CAN
Operating system
• Without operating system
• Windows Embedded Standard
2009 preinstalled
(CF from 2 GB/SSD/HD)
• XP Prof. MUI preinstalled
on SSD/HD
• Windows Embedded Standard 7
(32-bit) preinstalled
(CF from 4 GB/SSD/HD)
• Windows 7 (32-bit) MUI
preinstalled on SSD/HD

6ES7647- 8 A 7 7 7 - 7 7 7 7

SIMATIC IPC227D
Software bundles
• Without RTX/HMI software
• RTX: WinAC RTX 2010
• RTX-F: WinAC RTX F 2010
• HMI: WinCC RT Advanced 128 PT
• HMI: WinCC RT Advanced 512 PT
• HMI: WinCC RT Advanced
2048 PT
• HMI/RTX: RT 128 PT
• HMI/RTX: RT 512 PT
• HMI/RTX: RT 2048 PT
• HMI/RTX-F: RT 128 PT
• HMI/RTX-F: RT 512 PT
• HMI/RTX-F: RT 2048 PT

A

A
B
C
F
G
H
M
N
P
R
S
T

Device versions
• Device version: Base line
• Device version: PCIe (1 slot)
• Device version: COM
(COM2-4: RS232)
• Device version: IO
(4x dig. in/out each)

B
E
F
G
H

A
B
D
E

Mounting accessories
• Standard mounting rail
• Wall mounting
• Portrait mounting
• Side mounting

0
1
3

1
2
3
4

Release for individual order variants: See releases in the
ordering procedure.

4
5
6
7
8

Accessories
Cable strain relief set for IPC227D
Packing unit: 5 units

6ES7648-1AA50-0XL0

Dust protection set for IPC227D

6ES7648-1AA50-0XG0

5

0
1
2
0
1

2
3

4

Siemens ST 80 / ST PC · 2013

5/33

© Siemens AG 2013

PC-based Automation
Box PC
SIMATIC IPC227D

■ Dimensional drawings
All dimensions in mm. For mounting cut-out see technical specifications.
46
28

4.8
21.5

4.8

19

21

220

231.5

198

220

231.5

20.3

14.5

15

197

76.6
56

2.5

105

SIMATIC IPC227D basic unit, portrait mounting

93.1

G_ST80_XX_00475

100

90.6

G_ST80_XX_00474

60

62

2

100
105

SIMATIC IPC227D COM version, portrait mounting

5








60

SIMATIC IPC227D basic unit, standard rail mounting

5/34

Siemens ST 80 / ST PC · 2013

100
50
8.5

SIMATIC IPC227D COM version, standard rail mounting

G_ST80_XX_00465

8.5

G_ST80_XX_00464

50

100

90.6

© Siemens AG 2013

PC-based Automation
Box PC
SIMATIC IPC227D

■ Dimensional drawings (continued)

■ More information
76.6
56

4.8
21

Further information can be found on the Internet at:
http://www.siemens.com/simatic-pc

20.3

220

198

231.5

14.5

G_ST80_XX_00476

90.6

93.1

2.5

187
192

SIMATIC IPC227D PCIe version, portrait mounting

5



8.5

G_ST80_XX_00473

93.5

167

90.6

SIMATIC IPC227D PCIe version, standard rail mounting

Siemens ST 80 / ST PC · 2013

5/35

© Siemens AG 2013

PC-based Automation
Box PC
SIMATIC IPC427D

■ Overview
SIMATIC IPC427D (Microbox PC):
The powerful embedded IPC – maintenance-free
with versatile configuration
Ready-to-run, complete solutions (software is already installed
and preconfigured) for visualization and automation in
connection with WinCC RT Advanced and/or WinAC RTX:
• Ultra-compact
• Maintenance-free
• Third generation Intel Core i technology

■ Technical specifications
SIMATIC IPC427D

Design

• DIN rail mounting
• Wall mounting
• Portrait mounting
• Intel Celeron 827E 1.4 GHz,
1.5 MB SLC
• Intel Core i3-3217UE 1.6 GHz,
3 MB SLC
• Intel Core i7-3517UE 1.7 GHz,
4 MB SLC

Processor

SIMATIC IPC427D
USB stick

General features

External, can be connected
via USB port

Interfaces
Serial

• COM1 (RS 232)
• COM2 (RS 232); optional

Graphics

• DVI-I: Can be used as DVI or VGA
• DPP++: Display port, DVI via
DPP-to-DVI adapter

USB

Memory module without ECC:
• 1 GB DDR3-SDRAM SODIMM
• 2 GB DDR3-SDRAM SODIMM
• 4 GB DDR3-SDRAM SODIMM
• 8 GB DDR3-SDRAM SODIMM

4 x USB 3.0, max. 2 high-current at
the same time, downward-compatible
with USB 2.0/1.1

Ethernet

Memory module with ECC:
• 4 GB DDR3-ECC SODIMM
• 8 GB DDR3-ECC SODIMM

• 2 x RJ45 (10/100/1000 Mbps)
teaming-capable or
• 1 x RJ45 (10/100/1000 Mbps)
with PROFINET versions

PROFIBUS DP

12 Mbps (isolated, compatible with
CP 5622), optional

Free slots for expansions

Up to 2 x PCIe cards, depending on
enclosure design

PROFINET

3 x RJ45 (10/100 Mbps),
CP 1616 onboard, optional

Graphics

• Integrated Intel HD2000 or HD4000
• DVI resolution of 640 x 480 pixels up
to 1920 x 1200 pixels
• Maximum display port resolution
1920 x 1200 pixels
• Graphics memory is occupied in the
main memory (UMA dynamic)

CAN interface

Optional

Keyboard, mouse

Connection via USB port

Main memory

5

Power supply

24 V DC (-20%/+20%) max. 4 A

Rated conditions

Fan-free operation

Advanced device functions
Temperature

• When permitted operating
temperature range is exceeded
• Warnings can be analyzed by the
application program (local, via LAN)

Watchdog

• Monitoring function for program
execution
• Restart can be parameterized in the
event of a fault
• Warnings can be analyzed by the
application program (local, via LAN)

LED display

4 LEDs for displaying system status,
3 of these can be programmed by the
user

Short-term voltage dip

Up to 15 ms buffer time at full load

Buffer memory

512 KB MRAM optional

Operating systems
Available

• without
• Windows Embedded Standard 7
• Windows 7 Ultimate MUI

Project-specific

• Linux
• QNX
• VxWorks

Drives and storage media
CFast card

•
•
•
•

Hard disk

• 2.5", 1 x ≥ 250 GB, SATA

Solid-state drive (SSD)

• 1 x ≥ 50 GB, 2.5" SATA-SSD,
high endurance or
• 1 x ≥ 80 GB, 2.5" SATA-SSD,
standard or
• 1 x ≥ 160 GB, 2.5" SATA-SSD,
standard

5/36

2 GB optional or
4 GB optional or
8 GB optional or
16 GB optional

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
Box PC
SIMATIC IPC427D

■ Ordering data
SIMATIC IPC427D (Box PC) 1) 2)
Processor and fieldbus:
• Celeron U827E
(1C/1T, 1.4 GHz, 1.5 MB cache);
2 x Gigabit Ethernet (IE/PN)
• Celeron U827E
(1C/1T, 1.4 GHz, 1.5 MB cache);
2 x Gigabit Ethernet (IE/PN);
PROFIBUS DP12
• Celeron U827E
(1C/1T, 1.4 GHz, 1.5 MB cache);
2 x Gigabit Ethernet (IE/PN);
CAN interface
• Core i3-3217UE
(2C/4T, 1.6 GHz, 3 MB cache);
2 x Gigabit Ethernet (IE/PN)
• Core i3-3217UE
(2C/4T, 1.6 GHz,3 MB cache);
2 x Gigabit Ethernet (IE/PN);
PROFIBUS DP12
• Core i3-3217UE
(2C/4T, 1.6 GHz, 3 MB cache);
1 x Gigabit Ethernet (IE/PN);
1 x PROFINET (IRT, 3 ports)
• Core i7-3517UE
(2C/4T, 1.7 (2.8) GHz,
3 MB cache); 2 x Gigabit Ethernet
(IE/PN) (optional ECC only here)
• Core i7-3517UE
(2C/4T, 1.7 (2.8) GHz, 3 MB
cache); 2 x Gigabit Ethernet
(IE/PN); PROFIBUS DP12
• Core i7-3517UE
(2C/4T, 1.7 (2.8) GHz, 3 MB
cache); 1 x Gigabit Ethernet
(IE/PN); 1 x PROFINET
(IRT, 3 ports)
Mounting accessories:
• DIN rail mounting
• Wall mounting
• Portrait mounting
Work memory/NVRAM/ECC:
• 1 GB
• 2 GB
• 4 GB
• 8 GB
• 4 GB with ECC (only with Core i7,
2 x Gigabit Ethernet (IE/PN))
• 8 GB with ECC (only with Core i7,
2 x Gigabit Ethernet (IE/PN))
• 1 GB and NVRAM
• 2 GB and NVRAM
• 4 GB and NVRAM
• 8 GB and NVRAM
• 4 GB with ECC and NVRAM (only
with Core i7, 2 x Gigabit Ethernet
(IE/PN))
• 8 GB with ECC and NVRAM (only
with Core i7, 2 x Gigabit Ethernet
(IE/PN))
Expansions/interface:
• One RS 232, without PCIe
• One RS 232 and one PCIe
• One RS 232 and two PCIe
• Second RS 232, without PCIe
• Second RS 232 and one PCIe
• Second RS 232 and second PCIe
Operating system:
• Without operating system
• Windows Embedded Standard 7
SP1, English, 32-bit
• Windows 7 Ultimate SP1, 32-bit,
MUI (Eng, Ger, Fr, It, Sp)
• Windows 7 Ultimate SP1, 64-bit,
MUI (Eng, Ger, Fr, It, Sp)

Order No.

Order No.

6AG4140- 7 7 7 7 7 - 7 7 7 7

SIMATIC IPC427D (Box PC) 1) 2)
(continued)

6AG4140- 7 7 7 7 7 - 7 7 7 7

Mass storage, externally accessible:
• Without external mass storage
• CFast 2 GB
Without operating system
• CFast 4 GB
(only optionally with operating system if no internal mass storage)
• CFast 8 GB
(only optionally with operating system if no internal mass storage)
• CFast 16 GB
(only optionally with operating system if no internal mass storage)

0

1

2

3

Internal mass storage:
• Without internal mass storage
• CFast 2 GB, without software
• CFast 4 GB, without software
• CFast 8 GB, without software
• CFast 16 GB, without software
• SSD 50 GB high endurance (SLC)
• SSD 80 GB Standard
• HDD 250 GB
• SSD 160 GB Standard

4

5

6

SIMATIC software preinstalled
(bundles, only with Windows
Embedded Standard 7):
• Without SIMATIC software
• WinAC RTX 2010 3)
• WinCC RT Advanced, 128 PT
• WinCC RT Advanced, 512 PT
• WinCC RT Advanced, 2048 PT
• WinCC RT Advanced, 4096 PT
• WinCC RT Advanced 128 PT,
WinAC RTX 2010 3)
• WinCC RT Advanced 512 PT,
WinAC RTX 2010 3)
• WinCC RT Advanced 2048 PT,
WinAC RTX 2010 3)
• WinCC RT Advanced 4096 PT,
WinAC RTX 2010 3)
• WinAC RTX F 2010 3)
• WinCC RT Advanced 128 PT,
WinAC RTX F 2010 3)
• WinCC RT Advanced 512 PT,
WinAC RTX F 2010 3)
• WinCC RT Advanced 2048 PT,
WinAC RTX F 2010 3)
• WinCC RT Advanced 4096 PT,
WinAC RTX F 2010 3)

7

8

B
D
E
A
B
C
D
G
H
J
K
L
M
N

Power supply:
• 24 V DC
industrial power supply
• 24 V DC and TPM
(not for China and Russia)

P

0
1
2
3
4
5

0
1
2

3

4

A
B
C
D
E
G
H
K
P

A
B
C
D
E
F
J

5

K
L
M
N
P
Q
R
S

0
8

1)

"Built to order" – versions with a delivery time of max. 15 working days and
with identified repair, if not preferred type.

2)

For an up-to-date overview, see the SIMATIC PC online configurator at:
www.siemens.com/ipc-configurator

3)

Only with "main memory and NVRAM".

Note:
0
4

Bundles with SIMATIC software only with Windows Embedded
Standard 7, main memory and NVRAM (with RTX and RTX F),
and CFast mass storage of 4 GB or more / SSD.

6
7

Siemens ST 80 / ST PC · 2013

5/37

© Siemens AG 2013

PC-based Automation
Box PC
SIMATIC IPC427D

■ Dimensional drawings

1.5
133
6.7

1.5

16.5

184
262

85
100

50

16.5

2

262
50

10

50.5

All dimensions in mm. For mounting cut-out see technical specifications.

SIMATIC IPC427D, wall mounting

315

300

272

21.5

6.1

SIMATIC IPC427D, DIN rail mounting

5

25

15.3

143

55.5
61.5
G

SIMATIC IPC427D, portrait mounting

5/38

Siemens ST 80 / ST PC · 2013

G_ST80_XX_00555

8.9

2.5
5.8

G_ST80_XX_00554

286
297

G

50.5

G

9

G_ST80_XX_00553

6.7

133

83.7

Ø 4.5

© Siemens AG 2013

PC-based Automation
Box PC
SIMATIC IPC427C

■ Overview

■ Technical specifications
SIMATIC IPC427C
General features
Design

DIN rail or wall mounting, front upright
mounting, mounting position preferably horizontal, vertical possible

Processor

• Intel Core2 Duo 1.2 GHz,
800 MHz FSB, 3 MB SLC
• Intel Core2 Solo 1.2 GHz,
800 MHz FSB, 3 MB SLC
• Intel Celeron M 1.2 GHz,
800 MHz FSB, 1 MB SLC

Chipset

Intel GM45 / ICH9M

Main memory

1 GB, (2/4 GB) DDR3 SDRAM

Buffered SRAM

2 MB, of which 128 KB can be written
within the buffer time

Free slots for expansions

Up to 3 x PCI-104, 3 W per slot

Graphics

• Integrated Intel GMAX4500
graphics
• 8 ... 512 MB shared graphics memory (managed dynamically)
• CRT resolution: 640 x 480 pixels
up to max. 1920 x 1200 pixels at
32 bit colors
• DVI-D resolution: 640 x 480 pixels
up to max. 1920 x 1200 pixels at
32 bit colors

Operating system

• Without
• Windows XP Embedded Standard
2009 preinstalled, in combination
with CF card of 2 GB or more,
solid-state drive, or hard drive
• Windows XP Professional MUI
(in combination with solid-state
drive or hard drive; MUI:
Multi Language User Interface)
• Windows 7 Ultimate MUI (in combination with solid-state drive or hard
drive; MUI: Multi Language User
Interface)
• Windows Embedded Standard 7
preinstalled, in combination with CF
card of 4 GB or more, or solid-sate
drive, or hard drive RMOS3 (can be
ordered separately)
• Linux1)
(project-specific, on request)
• Others on request project-specifically

SIMATIC IPC427C (Microbox PC): The powerful embedded
IPC – maintenance-free with versatile configuration
• Ultra-compact
• Maintenance-free
• Intel Core2 Duo technology

Power supply

1)

• 24 V DC (19.2 V ... 28.8 V)
• Isolated
• With buffering of temporary power
failures: Max. 10 ms at 0.85% rated
voltage
• Line side switch
• With power failure indication by
means of Power Fail signal

Suitable for specific LINUX versions in accordance with the specifications
of the Siemens manufacturer's declaration "Suitable for LINUX", see
http://www.siemens.com/simatic-pc/suited-for-linux
(LINUX is a trademark of Linus Torvald).

Siemens ST 80 / ST PC · 2013

5/39

5

© Siemens AG 2013

PC-based Automation
Box PC
SIMATIC IPC427C

■ Technical specifications (continued)
SIMATIC IPC427C
Drives
Flash drive

Optional; replaceable, accessible,
diagnosable
• 2 GB
• 4 GB
• 8 GB
• 16 GB
Optional; internal, not accessible,
diagnosable
• 2 GB
• 4 GB
• 8 GB
• 16 GB

Solid-State Drive (SSD)

Optional
• 50 GB SATA, 2.5" in single-level cell
(SLC) architecture (High Endurance), especially suitable for
industrial applications
• 80 GB SATA, 2.5" Standard

Hard disk

Optional
• > 250 GB SATA

CD-ROM

Via USB
(not included in scope of delivery)

DVD-RW

Via USB
(not included in scope of delivery)

Diskette

Via USB
(not included in scope of delivery)

Temperature

• Processor temperature
• Motherboard
• Messages can be evaluated by the
application program

Watchdog

• Monitoring of program execution
• Monitoring time can be parameterized in software
• Can be parameterized for a fault or
restart
• Messages can be evaluated by the
application program.

Monitoring functions via the network

• DiagBase
• SIMATIC IPC DiagMonitor
Remote monitoring capability for:
• Watchdog
• Temperature
• Mass memory monitoring (SMART)
• System/Ethernet monitoring
(Heart Beat)
• Runtime meter
Communication:
• Ethernet interface (SNMP protocol)
• OPC for integration in
SIMATIC software
• Configuration of client/server
architectures
• Layout of log files

Ambient conditions

Interfaces
PROFINET

3 x RJ45
(CP 1616-compatible, optional)

PROFIBUS/MPI

12 Mbit/s
(isolated, compatible to CP 5611)
optional

Ethernet

• 2 x 10/100/1000 Mbit/s (RJ 45)
• Two independent Intel 82574L
controllers (via PCI-Express)
• One controller with none-shared
interrupt
• With teaming function

USB

V2.0/High Speed: 4 x

Serial

COM1 (V.24)
COM2 (V.24) optional
(in expansion frame)

DVI-I

1 x DVI-I (includes DVI-D and VGA)

Keyboard

Via USB
(not included in scope of delivery)

Mouse

Via USB
(not included in scope of delivery)

5

SIMATIC IPC427C
Monitoring functions

Degree of protection to EN 60529
(front/rear)

IP20

Vibration load during operation

Devices without hard disk:
• Requirements according to:
IEC 61131-2
• Tested according to:
IEC 60068-2-6, Test Fc
• Devices without drive:
- 5-9 Hz, 3.5 mm deviation,
10x /axis, 1 octave/min
- 9-150 Hz, 9.8 m/s2, 10x /axis,
1 octave/min
Devices with hard disk:
Wall mounting
• Requirements according to:
IEC 61131-2
• Tested according to:
IEC 60068-2-6, Test Fc
• 10 ... 58 Hz, 0.0375 mm deviation,
10x /axis, 1 octave/min
• 58 ... 200 Hz, 4.9 m/s2, 10x /axis,
1 octave/min

Shock loading during operation

Devices without hard disk:
• Requirements according to:
IEC 61131-2
• Tested according to:
IEC 60068-2-27, Test Ea
• Module/rack: 150 m/s2, power-up,
11 ms shock duration
Devices with hard disk:
Wall mounting
• Requirements according to:
IEC 61131-2
• Tested according to:
IEC 60068-2-27, Test Ea
• Devices with drive: 50 m/s2,
power-up, 30 ms shock duration

5/40

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
Box PC
SIMATIC IPC427C

■ Technical specifications (continued)
SIMATIC IPC427C
Electromagnetic compatibility
(EMC)
• Emitted interference
• Interference immunity, burst

• Interference immunity, surge
• ESD interference immunity

• Immunity to high radio frequency
interference

• Immunity to high-frequency
current feed

• Immunity to magnetic fields

EN 55022 Class B
EN 61000-6-2 or IEC 61131-2:
• 2 kV - Tested acc. to IEC 61000-4-4
• 1 kV symmetrical / 2 kV asymmetrical - Tested acc. to IEC 61000-4-5
1 kV to IEC 61000-4-5; symmetrical
2 kV to IEC 61000-4-5; asymmetrical
According to NAMUR Recommendation NE 21 and EN 61000-6-2:
• 6 kV contact discharge Tested acc. to IEC 61000-4-2
• 8 kV air discharge Tested acc. to IEC 61000-4-2
According to EN 61000-6-2 or
IEC 61131-2:
• Interference immunity
80 ... 1000 MHz: 10 V/m with
80% AM (1 kHz); tested acc. to
IEC 61000-4-3;
• 1.4 GHz ... 2 Hz: 10 V/m with 50%
pulse modulation; tested according
to IEC 61000-4-3
Acc. to NAMUR Recommendation
NE 21 and EN 61000-6-2 or
IEC 61131-2:
• 10 kHz ... 80 MHz:
10 V with 80% AM (1 kHz)
tested acc. to IEC 61000-4-6
Acc. to NAMUR Recommendation
NE 21 and EN 61000-6-2 or
IEC 61131-2:

SIMATIC IPC427C
System-tested
SIMATIC Industrial Software

WinAC RTX (F), WinCC flexible,
WinCC (SCADA as of V7.0), WinCC
RT Advanced and Professional

Approvals

UL508, UL60950, cULus

Marine approval

•
•
•
•
•
•

Only for configurations with
CompactFlash or SSD memory

Safety regulations

• IEC 61131-2
• IEC 61010-1
• EN 60950-1

CE mark

• EC Directive 89/336/EEC
(EMC Directive)
• Use in industry:
• Applications in residential areas,
business and trade environments as
well as in workshops:
- Emitted interference:
EN 61000-6-4
- Noise immunity: EN 61000-6-2
• Applications in residential areas,
business and trade environments as
well as in workshops:
- Emitted interference:
EN 61000-6-3
- Noise immunity: EN 61000-6-1

Dimensions and weights
Equipment dimensions (in mm)

•
•
•
•

Weight, approx.

2 kg

50/60 Hz; 100 A/m rms value
- tested acc. to IEC 61000-4-8
Ambient temperature
during operation

Moist heat

• 0 ... 55 ºC with flash drive/SSD
(horizontal; preferred mounting
position; with derating)
• 0 ... 50 ºC with flash drive/SSD
(horizontal; preferred mounting
position; maximum configuration)
• 0 ... 50 ºC with flash drive/SSD
(vertical)
• 5 ... 40 ºC with hard disk
(horizontal and vertical)

GL - Germanische Lloyd
BV - Bureau Veritas
LR - Lloyds Register of Shipping
ABS - American Bureau of Shipping
DNV - Det Norske Veritas
NKK - Nippon Kaiji Kyokai

Width x height: 262 x 134
Depth of basic unit: 47
Depth of basic unit above rail: 50
Additional depth per expansion
(1-3): 17 each

5

• With CompactFlash card/SSD: 95 %
• With hard drive 80%

Siemens ST 80 / ST PC · 2013

5/41

© Siemens AG 2013

PC-based Automation
Box PC
SIMATIC IPC427C

■ Ordering data
SIMATIC IPC427C 1)

Order No.

Order No.

6ES7647- 7 B 7 7 7 - 7 7 7 0

Memory expansion
• 1 GB DDR3 1066 SDRAM,
SODIMM
• 2 GB DDR3 1066 SDRAM,
SODIMM
• 4 GB DDR3 1066 SDRAM,
SODIMM

Intel Celeron M 1.2 GHz, 800 MHz
FSB, SLC 0 KB; 512 MB DDR3
RAM; without HD; without flash
drive; without operating system;
24 V DC industrial power supply
Processor:
• Intel Celeron M 1.2 GHz,
800 MHz FSB
• Intel Celeron M 1.2 GHz,
800 MHz FSB, PROFIBUS
• Intel Celeron M 1.2 GHz,
800 MHz FSB, CAN
• Core2 Solo 1.2 GHz,
800 MHz FSB SLC, 3 MB
• Core2 Solo 1.2 GHz, 800 MHz FSB
SLC, 3 MB, PROFIBUS
• Core2 Solo 1.2 GHz, 800 MHz FSB
SLC, 3 MB, PROFINET
• Core2 Duo 1.2 GHz, 800 MHz FSB
SLC, 3 MB
• Core2 Duo 1.2 GHz, 800 MHz FSB
SLC, 3 MB, PROFIBUS
• Core2 Duo 1.2 GHz, 800 MHz FSB
SLC, 3 MB, PROFINET

A
B
D
E
F
G
J
K
L

Memory configuration:
• 1 GB DDR3 1066, SODIMM
• 2 GB DDR3 1066, SODIMM
• 4 GB DDR3 1066, SODIMM
Expansion (HW):
• No expansion (HW)
• Second RS232 interface
in expansion rack

5

Drives exchangeable (accessible)
• Without drive
• 2 GB CompactFlash
• 4 GB CompactFlash
• 8 GB CompactFlash
• 16 GB CompactFlash

2
3
4

6ES7648-2AH40-0KA0
6ES7648-2AH50-0KA0
6ES7648-2AH60-0KA0

Expansion kit PC/104
For integration of PC/104 modules in
the SIMATIC Microbox PC; packing
unit contains 6 expansion frames

6AG4070-0BA00-0XA0

SIMATIC PC adapter cable
DVI-I acc. to VGA, 250 mm

6ES7648-3AB00-0XA0

SIMATIC PC DVI-I Y graphics
adapter cable
DVI-I to VGA and DVI-D

6ES7648-3AE00-0XA0

Portrait assembly kit
Interfaces to the front

6ES7648-1AA20-0YB0

Expansion components

From page 5/153

Communication products

From page 5/186

For power supplies and
uninterruptible power supplies

From page 5/170

RMOS3 real-time operating
system

From page 5/146

0
1

0
2
3
4
5

Drives internal (not accessible)
• Without internal drive
• 250 GB HDD SATA
• 50 GB SSD High Endurance SATA
• 80 GB Standard SATA
• 2 GB CompactFlash internal
• 4 GB CompactFlash internal
• 8 GB CompactFlash internal
• 16 GB CompactFlash internal
Operating system
(preinstalled and activated)2)
• Without operating system
• Windows Embedded Standard
2009 English preinstalled on internal drive
• Windows XP Professional MUI,
SP3 (Eng, Ger, Fr, It, Sp) preinstalled on internal drive
• Windows Embedded Standard 7
preinstalled on internal drive
• Windows 7 Ultimate, 32-bit, MUI
(Eng, Ger, Fr, It, Sp) preinstalled on
internal drive

Accessories

X
A
D
E
N
P
Q
R

0
0

X
A

0

B

0

C

0

D

1)

For an up-to-date overview, see the SIMATIC PC online configurator at:
www.siemens.com/ipc-configurator

Note:

2)

XP Embedded on 2 GB CompactFlash or hard disk.
XP Professional or Windows 7 only with hard disk/SSD.

Ready-to-use SIMATIC IPC427C as bundles can be found
under "Embedded Bundles".
Software packages with SIMATIC WinCC flexible, SIMATIC
WinCC RT Advanced, SIMATIC WinCC, SIMATIC WinCC RT
Professional and SIMATIC WinAC RTX (F) can be ordered
together with the SIMATIC IPC with a price advantage.

5/42

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
Box PC
SIMATIC IPC427C

■ Dimensional drawings

SIMATIC IPC427Cb

262

138

G_ST80_XX_00456

46.5

*B67B;;B

138

133
262

52.5
97.5

All dimensions in mm. For mounting cut-out see technical specifications.

SIMATIC IPC427C, interfaces

■ More information
Further information can be found in the Internet under:
http://www.siemens.com/simatic-pc

5

Siemens ST 80 / ST PC · 2013

5/43

© Siemens AG 2013

PC-based Automation
Box PC
SIMATIC IPC627C

■ Overview

■ Technical specifications
SIMATIC IPC627C
Supply voltage
Supply voltage
Processor
Processor

Interfaces
PROFIBUS/MPI

SIMATIC IPC627C (Box PC):
The high-end IPC – with maximum performance,
functional scope and expansion capability
It offers:
• Maximum performance in the smallest space
• Intel Core i7 technology

Free slots

2 X PCI or 1xPCI & 1 x PCIe X16
(265 mm/185mm long) , 1xslot for
CompactFlash Card

Connection for keyboard/mouse

USB / USB

serial interface

COM1: 1 x V.24 (RS232)

Video interfaces
• Graphics interface

DVI-I: VGA / DVI combined

Industrial Ethernet
• Industrial Ethernet interface

2 x Fast Ethernet

Monitoring functions
Temperature

Yes

Watchdog

Yes

Status LEDs

Yes

Standards, approvals, certificates
Approval

CE, cULus (508), C-Tick

Vibrations
• Vibration load in operation

Shock testing
• Shock loading in operation
Operating systems
Operating system

Software
SIMATIC Software

Siemens ST 80 / ST PC · 2013

Onboard, isolated, max. 12 Mbit/s,
CP5611-compatible
4x USB 2.0 high speed/high current

Ambient conditions
Relative humidity
• Relative humidity

5/44

Core i7-610E (2C/4T, 2.53 GHz,
TB, HT, VT, AMT, 4MB cache);
Core i3-330E (2C/4T, 2.13 GHz, HT,
VT, 3MB cache); Celeron P4505
(2C/2T, 1.86 GHz, VT, 2MB cache);

USB port

EMC

5

100 - 240 V AC, optional 24 V

CE, EN 55022A, EN 61000-6-4,
EN 61000-6-2

Tested to DIN IEC 68-2-3,
DIN IEC 68-2-30,
DIN IEC 68-2-56: 5% to 80%
at 25 °C (no condensation)
Tested to DIN IEC 68-2-6:
10 to 58 Hz: 0.075 mm,
58 to 200 Hz: 9.8 m/s2 (1 g)
Tested to DIN IEC 68-2-29:
50 m/s2 (5g), 30 ms, 100 shocks
Windows XP Prof. SP3, MUI;
Windows 7 Ultimate 32/64Bit, MUI;
Windows Embedded Standard 2009
English on 8 GB CompactFlash;
without operating system;
Optionally in package with
SIMATIC WinCC or WinCC flexible

Dimensions
Width

312 mm

Height

80 mm; with DVD drive: 100 mm

Depth

301 mm; incl. mounting rail

© Siemens AG 2013

PC-based Automation
Box PC
SIMATIC IPC627C

■ Ordering data
SIMATIC IPC627C 1)

Order No.

Order No.

6ES7647- 6 C 7 7 7 - 7 7 7 7

HD graphics on-board,
128 MB dyn. shared memory;
2 x 10/100/1000 Mbps Ethernet
RJ45; 4 x USB V2.0 (high current);
1 x serial (COM1), RAID controller
on-board;
CompactFlash drive no. 1 at front
(without CF);
watchdog, temp./fan monitoring;
Processor:
• Celeron P4505 (2C/2T, 1.86 GHz,
VT, 2 MB cache)
• Celeron P4505 (2C/2T, 1.86 GHz,
VT, 2 MB cache), PROFIBUS/MPI
(CP5611-compatible),
2 MB battery-backed SRAM
• Celeron P4505 (2C/2T, 1.86 GHz,
VT, 2 MB cache), PROFINET
(3 x RJ45, CP1616-compatible),
2 MB battery-backed SRAM
• Core i3-330E (2C/4T, 2.13 GHz,
HT, VT, 3 MB cache)
• Core i3-330E (2C/4T, 2.13 GHz,
HT, VT, 3 MB cache),
PROFIBUS/MPI,
2 MB battery-backed SRAM
• Core i3-330E (2C/4T, 2.13 GHz,
HT, VT, 3 MB cache), PROFINET
(3 x RJ45, CP1616-compatible),
2 MB battery-backed SRAM
• Core i7-610E (2C/4T, 2.53 GHz,
TB, HT, VT, AMT, 4 MB cache)
• Core i7-610E (2C/4T, 2.53 GHz,
TB, HT, VT, AMT, 4 MB cache),
PROFIBUS/MPI,
2 MB battery-backed SRAM
• Core i7-610E (2C/4T, 2.53 GHz,
TB, HT, VT, AMT, 4 MB cache),
PROFINET (3 x RJ45, CP1616compatible), 2 MB battery-backed
SRAM
Memory configuration
• 1 GB DDR3 1066 DIMM
• 2 GB DDR3 1066 DIMM
• 3 GB DDR3 1066 DIMM
• 4 GB DDR3 1066 DIMM
• 8 GB DDR3 1066 DIMM
• 2 GB DDR3 1066 DIMM, ECC
• 4 GB DDR3 1066 DIMM, ECC
• 8 GB DDR3 1066 DIMM, ECC
Country-specific version/
power supply
• 100/240 V AC industrial power
supply with Namur; European
cable
• 100/240 V AC industrial power
supply with Namur; UK cable
• 100/240 V AC industrial power
supply with Namur; Swiss cable
• 100/240 V AC industrial power
supply with Namur; USA cable
• 100/240 V AC industrial power
supply with Namur; Italian cable
• 100/240 V AC industrial power
supply with Namur; Chinese cable
• 24 V DC industrial power supply
Device Certification UL Class I
Div. 2; 24 V DC industrial
power supply
• Device Certification UL Class I
Div. 2; 110 / 230 V AC Industrial
Power Supply with Namur

SIMATIC IPC627C 1)
(continued)

6ES7647- 6 C 7 7 7 - 7 7 7 7

PC slots
• 2 x PCI free
• 1 x PCI, 1x PCIe (x16) free

0
1

Drives
• 250 GB HDD SATA
• 250 GB HDD SATA; DVD+/-RW
• 500 GB HDD SATA
• 500 GB HDD SATA; DVD+/-RW
• 2 x 250 GB SATA (2.5")
• 2 x 250 GB SATA (2.5") +
DVD+/-RW
• RAID1 2 x 250 GB SATA (2.5")
• RAID1 2 x 250 GB SATA (2.5");
DVD+/-RW
• 50 GB SATA solid-state drive (SLC)
• 50 GB SATA solid-state drive
(SLC); DVD+/-RW
• CompactFlash drive No. 2
installed, DVD+/-RW
• CompactFlash drive No. 2 installed
• DVD+/-RW
• Without drives

A
B

C

D
E

Operating system
(preinstalled and activated)
• Windows XP Professional MUI,
SP3 (Eng, Ger, Fr, It, Sp)
• Windows 7 Ultimate, MUI (Eng,
Ger, Fr, It, Sp), 32-bit, SP1 included
• Windows 7 Ultimate, MUI (Eng,
Ger, Fr, It, Sp), 64-bit, SP1 included
• Windows Embedded Standard
2009 English on 8 GB
CompactFlash
• Without operating system

F

G
H

J

Expansion
• No expansion (software)
• SIMATIC IPC DiagMonitor software
included
• SIMATIC IPC Image&Partition
Creator software included
• SIMATIC IPC DiagMonitor,
Image & Partition Creator software
included

0
1
2
3
4
5
6
7

A
B
C
D
E
F
G
H
J
K
U
V
W
X

A
B
C
F

X
0
1
2
3

0

1
2
3
4
5
6
7

8

1)

For an up-to-date overview, see the SIMATIC PC online configurator at:
www.siemens.com/ipc-configurator

Siemens ST 80 / ST PC · 2013

5/45

5

© Siemens AG 2013

PC-based Automation
Box PC
SIMATIC IPC627C
Order No.

SIMATIC PC,
230 V AC power cable
angled, 3 m for Box PC
and Panel PC for
• Austria, Belgium, Finland, France,
Germany, Netherlands, Spain,
Sweden
• United Kingdom
• Switzerland
• USA
• Italy
• China

5

295.2

3.9

78.5

11.2

6ES7648-1AA10-0YA0
6ES7648-1AA10-0YB0

G_ST80_XX_00457

Portrait assembly kit
• Interfaces upward/downward
• Interfaces to the front

6ES7648-3AB00-0XA0
6ES7648-3AE00-0XA0

3.6

265

Graphics adapter cable
• DVI-I acc. to VGA, 250 mm long
• DVI-I acc. to VGA and DVI-D,
250 mm long (Y cable)

6ES7648-2CA01-0AA0

6ES7900-1AA00-0XA0

6ES7900-1BA00-0XA0
6ES7900-1CA00-0XA0
6ES7900-1DA00-0XA0
6ES7900-1EA00-0XA0
6ES7900-1FA00-0XA0

■ More information

Expansion components

From page 5/153

Further information can be found in the Internet under:

Communication products

From page 5/186

http://www.siemens.com/simatic-pc

For power supplies and
uninterruptible power supplies

From page 5/170

RMOS3 real-time operating
system

From page 5/146

Note:
Software Packages with SIMATIC WinCC flexible, WinCC RT
Advanced, SIMATIC WinCC, and SIMATIC WinAC RTX (F) can
be ordered together with the SIMATIC IPC at favorable prices.
More information under "Embedded Bundles / Packages for
industrial PCs".

5/46

Siemens ST 80 / ST PC · 2013

272.8

PCI expansion card
with COM1 and LPT

6ES7648-2AJ40-0KA0
6ES7648-2AJ40-1KA0
6ES7648-2AJ50-0KA0
6ES7648-2AJ50-1KA0
6ES7648-2AJ60-0KA0
6ES7648-2AJ60-1KA0

99.8

All dimensions in mm. For mounting cut-out see technical specifications.

Accessories
Memory expansions
• 1 GB DDR3 1066, DIMM
• 1 GB DDR3 1066, DIMM; ECC
• 2 GB DDR3 1066, DIMM
• 2 GB DDR3 1066, DIMM; ECC
• 4 GB DDR3 1066, DIMM
• 4 GB DDR3 1066, DIMM; ECC

■ Dimensional drawings

99.1

■ Ordering data

© Siemens AG 2013

PC-based Automation
Box PC
SIMATIC IPC827C

■ Overview

■ Technical specifications
SIMATIC IPC827C
Supply voltage
Supply voltage

100 - 240 V AC, optional 24 V

Processor
Processor

Core i7-610E (2C/4T, 2.53 GHz,
TB, HT, VT, AMT, 4MB cache);
Core i3-330E (2C/4T, 2.13 GHz, HT,
VT, 3MB cache); Celeron P4505
(2C/2T, 1.86 GHz, VT, 2MB cache);

Interfaces
PROFIBUS/MPI

SIMATIC IPC827C (Box PC):
The high-end IPC – with maximum performance,
functional scope and expansion capability
It offers:
• Maximum performance and high expandability
• with Intel Core i technology

Onboard, isolated, max. 12 Mbit/s,
CP5611-compatible

USB port

4x USB 2.0 high speed/high current

Free slots

3xPCI, 1 x PCIe (x4), 1 x PCIe (x16),
1xslot for CompactFlash Card

Connection for keyboard/mouse

USB / USB

serial interface

COM1: 1 x V.24 (RS232)

Video interfaces
• Graphics interface

DVI-I: VGA / DVI combined

Industrial Ethernet
• Industrial Ethernet interface

2 x Fast Ethernet

Monitoring functions
Temperature

Yes

Watchdog

Yes

Status LEDs

Yes

Standards, approvals, certificates
Approval

CE, cULus (508), C-Tick

EMC
Ambient conditions
Relative humidity
• Relative humidity

Vibrations
• Vibration load in operation

Shock testing
• Shock loading in operation
Operating systems
Operating system

Software
SIMATIC Software

CE, EN 55022A, EN 61000-6-4,
EN 61000-6-2

Tested to DIN IEC 68-2-3,
DIN IEC 68-2-30,
DIN IEC 68-2-56: 5% to 80%
at 25 °C (no condensation)
Tested to DIN IEC 68-2-6:
10 to 58 Hz: 0.075 mm,
58 to 200 Hz: 9.8 m/s2 (1 g)
Tested to DIN IEC 68-2-29:
50 m/s2 (5g), 30 ms, 100 shocks
Windows XP Prof. SP3, MUI;
Windows 7 Ultimate 32/64Bit, MUI;
Windows Embedded Standard 2009
English on 8 GB CompactFlash;
without operating system;
Optionally in package with
SIMATIC WinCC or WinCC flexible

Dimensions
Width

312 mm

Height

150 mm; with DVD drive: 170 mm

Depth

301 mm; incl. mounting rail

Siemens ST 80 / ST PC · 2013

5/47

5

© Siemens AG 2013

PC-based Automation
Box PC
SIMATIC IPC827C

■ Ordering data
SIMATIC IPC827C

Order No.

Processor
• Celeron P 4505
(2C/2T, 1.86 GHz, VT, 2 MB cache)
• Celeron P 4505
(2C/2T, 1.86 GHz, VT,
2 MB cache); PROFIBUS/MPI;
2 MB battery-backed SRAM
• Celeron P 4505
(2C/2T, 1.86 GHz, VT,
2 MB cache);
PROFINET (3 x RJ45,
CP1616-compatible);
2 MB battery-backed SRAM
• Core i3-330E
(2C/4T, 2.13 GHz, HT, VT,
3 MB cache)
• Core i3-330E
(2.13 GHz, HT, VT,
3 MB cache); PROFIBUS/MPI;
2 MB battery-backed SRAM
• Core i3-330
(2C/4T, 2.13 GHz, HT, VT,
3 MB cache); PROFINET
(3 x RJ45, CP1616-compatible);
2 MB battery-backed SRAM
• Core i7-610E
(2C/4T, 2.53 GHz, TB, HT, VT,
AMT, 4 MB cache)
• Core i7-610E
(2C/4T, 2.53 GHz, TB, HT, VT,
AMT, 4 MB cache);
PROFIBUS/MPI;
2 MB battery-backed SRAM
• Core i7-610E
(2C/4T, 2.53 GHz, TB, HT, VT,
AMT, 4 MB cache);
PROFINET
(3 x RJ45, CP1616-compatible);
2 MB battery-backed SRAM

5

Memory configuration
• 1 GB DDR3 1066 DIMM
• 2 GB DDR3 1066 DIMM
• 3 GB DDR3 1066 DIMM
• 4 GB DDR3 1066 DIMM
• 8 GB DDR3 1066 DIMM
• 2 GB DDR3 1066 DIMM, ECC
• 4 GB DDR3 1066 DIMM, ECC
• 8 GB DDR3 1066 DIMM, ECC
Power supply
• 100/240 V AC industrial power
supply with Namur;
European cable
• 100/240 V AC industrial power
supply with Namur; UK cable
• 100/240 V AC industrial power
supply with Namur; Swiss cable
• 100/240 V AC industrial power
supply with Namur; USA cable
• 100/240 V AC industrial power
supply with Namur; Italian cable
• 100/240 V AC industrial power
supply with Namur; Chinese cable
• 24 V DC industrial power supply

5/48

Order No.

6ES7647- 6 P 7 7 7 - 7 7 7 7

Siemens ST 80 / ST PC · 2013

SIMATIC IPC827C
(continued)
Expansions (HW)
• 3 x PCI, 2 x PCIe (x4),
1 x PCIe (x16) available

A
B

Mass storage
• 250 GB HDD SATA
• 250 GB HDD SATA; DVD+/-RW
• 500 GB HDD SATA
• 500 GB HDD SATA; DVD+/-RW
• 2 x 250 GB SATA (2.5")
• 2 x 250 GB SATA (2.5") +
DVD+/-RW
• RAID1 2 x 250 GB SATA (2.5")
• RAID1 2 x 250 GB SATA (2.5");
DVD+/-RW
• Solid-state drive 50 GB (SLC)
• Solid-state drive 50 GB (SLC);
DVD+/-RW
• DVD+/-RW
• Without drives

C

D

E

F

Operating system
(preinstalled and activated)
• Windows XP Professional MUI,
SP3 (Eng, Ger, Fr, It, Sp)
• Windows 7 Ultimate, 32-bit, MUI
(Eng, Ger, Fr, It, Sp)
• Windows 7 Ultimate, 64-bit, MUI
(Eng, Ger, Fr, It, Sp)
• Windows XP Embedded Standard
2009 English on
8 GB CompactFlash
• Without operating system

G

H

J

Expansion software
• No expansion (software)
• SIMATIC IPC DiagMonitor software
included
• SIMATIC IPC Image&Partition
Creator included
• SIMATIC IPC DiagMonitor &
Image & Partition Creator included

0
1
2
3
4
5
6
7

6ES7647- 6 P 7 7 7 - 7 7 7 7

0

A
B
C
D
E
F
G
H
J
K
W
X

A
B
C
F

X
0
1
4
5

Note:
Windows Embedded only without
RAID option

0

1
2
3
4
5
6

Note:
Software Packages with SIMATIC WinCC flexible, WinCC RT
Advanced, SIMATIC WinCC, and SIMATIC WinAC RTX (F) can
be ordered together with the SIMATIC IPC at favorable prices.
More information under "Embedded Bundles / Packages for
industrial PCs".

© Siemens AG 2013

PC-based Automation
Box PC
SIMATIC IPC827C
Order No.

All dimensions in mm. For mounting cut-out see technical specifications.

Accessories

Portrait assembly kit
• Interfaces upward/downward
• Interfaces to the front
Power supply cable
SIMATIC PC, power cable for
230 V AC, angled, 3 m for Box PC
and Panel PC for
• Austria, Belgium, Finland, France,
Germany, Netherlands, Spain,
Sweden
• United Kingdom
• Switzerland
• USA
• Italy
• China

173.2
3

6ES7648-3AB00-0XA0
6ES7648-3AE00-0XA0

295.2

11

6ES7648-1AA30-0YA0
6ES7648-1AA30-0YB0

6ES7900-1AA00-0XA0

6ES7900-1BA00-0XA0
6ES7900-1CA00-0XA0
6ES7900-1DA00-0XA0
6ES7900-1EA00-0XA0
6ES7900-1FA00-0XA0

297.2

G_ST80_XX_00458

Graphics adapter cable
• DVI-I acc. to VGA, 250 mm long
• DVI-I acc. to VGA and DVI-D,
250 mm long (Y cable)

6ES7648-2CA01-0AA0

2.4

PCI expansion card
with COM1 and LPT

6ES7648-2AJ40-0KA0
6ES7648-2AJ40-1KA0
6ES7648-2AJ50-0KA0
6ES7648-2AJ50-1KA0
6ES7648-2AJ60-0KA0
6ES7648-2AJ60-1KA0

269.8

Memory expansions
• 1 GB DDR3 1066, DIMM
• 1 GB DDR3 1066, DIMM; ECC
• 2 GB DDR3 1066, DIMM
• 2 GB DDR3 1066, DIMM; ECC
• 4 GB DDR3 1066, DIMM
• 4 GB DDR3 1066, DIMM; ECC

■ Dimensional drawings

265

■ Ordering data

■ More information

Expansion components

From page 5/153

Weitere Informationen finden Sie im Internet unter:

Communication products

From page 5/186

http://www.siemens.com/simatic-pc

For power supplies and uninterruptible power supplies

From page 5/170

RMOS3 real-time operating
system

From page 5/146

5

Siemens ST 80 / ST PC · 2013

5/49

© Siemens AG 2013

PC-based Automation
SIMATIC Panel PC
Panel PC

■ Overview
SIMATIC IPC277:
The embedded Nanopanel PC – maintenance-free and
compact with displays starting from 7"
• High degree of flexibility for selecting rugged widescreen
fronts from 7" to 19" for a more freely configurable display area
• High resolution, large viewing angle, and up to 100%
dimmable backlighting for a brilliant display with optimized
power consumption
• Absolutely maintenance-free due to the use of CompactFlash
or SSD as mass storage and fanless operation up to 50 °C
ambient temperature
• Maximum industrial functionality due to non-volatile retentive
memory (option)
• Ready-to-use embedded bundles with visualization and/or
control software

SIMATIC Panel PCs are suitable thanks to their high industrial
compatibility for use in control cabinets, consoles and control
panels, as well as directly on the machine. Typical areas of application can be found in both factory and process automation.
There is a broad range of robust, high-performance
SIMATIC Panel PCs available for different requirements.

5

Shared industrial functionality
• High-quality components and modules with a high MTBF
(mean time between failure), which also ensure 24-hour
operation in the extended temperature range.
• High swing/shock capacity of the devices through special
hard-disk suspensions, locked connectors and card retainers
• Rugged housing model with high electromagnetic compatibility (EMC) and integrated industrial power supplies
(also as per NAMUR)
• Service-friendly device design
• Bright, brilliant displays in different sizes up to 19"
• Same front panel mounting dimensions and uniform front
design across all device families
• Rugged fronts protected from dust, humidity and chemical
substances (front-side IP65 / NEMA 4 degrees of protection)

SIMATIC IPC477D:
The powerful embedded Panel PC – maintenance-free with
versatile configuration
• Compact design
• High performance with highly compact design and
ruggedness
• Flexible expansion using a PCIe I/O card (optional)
• No rotating parts (without fan and hard disk)
• High security due to Windows Embedded Standard 7
operating system
• Ready-to-use devices with optionally preinstalled software
- HMI: Innovative HMI software WinCC RT Advanced
(incl. archives and recipes)
- RTX: with real-time capable software PLC WinAC RTX
• Retentive memory on board
(NV-RAM, usable with WinAC RTX)
SIMATIC HMI IPC477C:
The powerful embedded Panel PC – maintenance-free with
versatile configuration
• Compact design
• High performance with highly compact design and
ruggedness
• Also available as PRO version (all-round IP65 degree of
protection) with 15" and 19" Touch displays
• No rotating parts (without fan and hard disk)
• High security due to Microsoft Windows Embedded Standard
2009 or Windows Embedded Standard 7 operating systems
• Ready-to-use devices with optionally preinstalled software
- HMI: Innovative HMI software WinCC flexible
(incl. archives and recipes)
- RTX: with real-time capable software PLC WinAC RTX
• Retentive memory on board
(NV-RAM, usable with WinAC RTX)
SIMATIC HMI IPC677:
The high-end Panel PC – with maximum performance,
functional scope and expansion capability
• Rugged, expandable industrial PC with different front panels
• Rugged design for industrial use
• Complete PC openness
• Optional PROFIBUS or PROFINET onboard
• All CPUs with dual core

5/50

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
SIMATIC Panel PC
Panel PC

■ Overview (continued)
SIMATIC IPC277D

SIMATIC IPC477D

SIMATIC HMI
IPC477C

SIMATIC HMI
IPC577C

SIMATIC HMI
IPC677C 7)

Centralized configuration

•

•

•

•

•

Distributed configuration
(via remote kit)

-

-

-

-

-

Size

7"/9"/12"/15"/19“
Widescreen TFT

12"/15"/19"/22"
Widescreen TFT

12"/15"/19" TFT

12"/15"/19" TFT

12"/15"/19" TFT

Resolution

800 x 480 /
800 x 480 /
1280 x 800 /
1280 x 800 /
1366 x 768

1280 x 800 /
1280 x 800 /
1366 x 768/

800 x 600/
1024 x 768/
1280 x 1024

800 x 600/
1024 x 768/
1280 x 1024

800 x 600/
1024 x 768/
1280 x 1024

Membrane keyboard

-

• 8)

• 1)

• 1)

• 1)

Touch screen

•

•

•

•

•

Power supply
24 V DC / 110/240 V AC

•/-

•/-

•/-

•/•

•/•

Processor

• Intel Atom E640,
1.0 GHz;
• Intel Atom E660,
1.3 GHz

• Intel Core i73517UE, 1.7 GHz,
4 MB SLC
• Intel Core i33217UE, 1.6 GHz,
3 MB SLC
• Intel Celeron 827E
1.4 GHz, 1.5 MB
SLC

• Intel Celeron M
1.2 GHz
• Intel Core2 Solo
1.2 GHz
• Intel Core2 Duo
1.2 GHz

• Intel Celeron M
1.2 GHz
• Intel Core2 Solo
1.2 GHz
• Intel Core2 Duo
1.86 GHz

• Intel Celeron P4505,
1.86 GHz, 2 cores,
2 MB cache
• Intel Core i3-330E,
2.13 GHz, 2 cores,
4 threads, 3 MB
cache, HT, VT-x
• Intel Core i7-620E,
2.53 GHz, 2 cores,
4 threads, 4 MB
cache, TB, HT, VT-x,
VT-d

Main memory

1 GB, 2 GB

1 GB, 2 GB, 4 GB,
8 GB

1 GB, 2 GB, 4 GB

1 GB, 2 GB, 4 GB

1 GB, expandable up
to 8 GB, optional ECC

Expansion slots

1 x CF slot for
CompactFlash card
(externally accessible)

• 1 x PCIe;
• 2 x CFast slot
(externally
accessible)

2 x CF slot for
CompactFlash Card
(internally and externally accessible)

• 1 x PCI 2)
• 1 x CF slot for
CompactFlash card
(externally accessible)

• 2 x PCI or 1 x PCI
and 1 x PCIe x16
• 1 x CF slot for
CompactFlash card
(externally
accessible)

Operating system

• Windows
Embedded Standard 2009 or XP
Professional MUI
• Windows
Embedded
Standard 7 (32-bit)
or Windows 7
Ultimate MUI
(32-bit)

• Without
• Windows 7 Ultimate
MUI
(32-bit or 64-bit)
• Windows
Embedded
Standard 7 (32-bit)

• Windows Embedded 2009 or XP
Professional MUI
• Windows 7 Ultimate
MUI (32-bit) or
Windows
Embedded
Standard 7 (32-bit)

• Without
• Windows
Embedded 2009
or XP Professional
MUI

• Without
• Windows XP
Professional MUI
• Windows 7 Ultimate
32-bit MUI
• Windows 7 Ultimate
64-bit MUI
• Windows Embedded Standard 2009
on CF

Design

Display

1920 x 1080

Operator controls

General features

Interfaces
PROFIBUS/MPI

-

•

•

•

•

PROFINET (RT/IRT)

•/-

•/•

•/•

•/•

•/•

Ethernet

2x
10/100/1000 Mbps

2x
10/100/1000 Mbps

2x
10/100/1000 Mbps

2x
10/100/1000 Mbps

2x
10/100/1000 Mbps

USB

•

•

•

•

•

Serial interface

•

•

•

•

•

Graphics interface

-

•

•

•

•

Siemens ST 80 / ST PC · 2013

5/51

5

© Siemens AG 2013

PC-based Automation
SIMATIC Panel PC
Panel PC

■ Overview (continued)
SIMATIC IPC277D

SIMATIC IPC477D

SIMATIC HMI
IPC477C

SIMATIC HMI
IPC577C

SIMATIC HMI
IPC677C 7)

Vibration load during operation

1g

1g

1g

1 g 3)

1 g 3)

Shock loading during operation

5g

5g

5g

5 g 3)

5g

Permissible temperature during
operation with maximum configuration

+0 °C … +50 °C 7)

+0 °C … +50 °C 7)

+0 °C … +50 °C 7)

+0 °C … +45 °C 7)

+5 °C … +50 °C 6) 8)

Ambient conditions

Power loss in maximum
configuration
7" display

27 W

9" display

29 W

12" display

34 W

55 W

40 W 4)

55 W 5)

140 W 5)

15" display

42 W

56 W

45 W 4)

57 W 5)

140 W 5)

19" display

45 W

65 W

60 W 4)

84 W 5)

163 W 5)

22" display

74 W

• Available
- Not available

5

1)

12"/15" displays

2)

All slots with card retainer

3)

Valid with CF or SSD; with HDD: 5 g / 0.5 g;

4)

3 W taken into account for each PCI/PCIe slot

5)

15 W taken into account for each PCI/PCIe slot

6)

+0 °C to +50 °C; max. +50 °C in installation space;
max. 40 °C if at the front

7)

+0 °C to +45 °C for 19"

8)

15" display optionally as Touch/Key version

9)

With 12" and 15", vertical installation and use of CFast or SSD

■ More information
Additional information is available on the Internet at:
http://www.siemens.com/simatic-panel-pc
Note:
Do you need a specific modification or extension to the products
described here? Then refer to "Customized Automation". There
you will find information about additional and generally available
sector-specific products as well as options for customer-specific
modification and adaptation.
Examples are:
• Specific front panels for SIMATIC Panel PC, e.g. honing
oil-resistant or with lateral function/movement keys
• SIMATIC HMI Net Panel with 46" large-scale display

5/52

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
SIMATIC Panel PC
SIMATIC IPC277D

■ Overview

■ Technical specifications
SIMATIC IPC277D
General features

SIMATIC IPC277D: The embedded Nanopanel PC – maintenance-free and compact with displays starting from 7"
• Offers great flexibility in the selection of rugged widescreen
fronts
• From 7" to 19" for more freely configurable display area
• High resolution, large viewing angle, and up to 100%
dimmable backlighting for a brilliant display with optimized
power consumption
• Absolutely maintenance-free due to the use of CompactFlash
and SSD as mass storage and fanless operation up to 50 °C
ambient temperature
• Maximum industrial functionality due to non-volatile retentive
memory
• Ready-to-use embedded bundles with visualization or/and
control software
The following front installation versions are available:
• 7" Touch
• 9" Touch
• 12" Touch
• 15" Touch with USB interface on the front
• 19" Touch with USB interface on the front
• All fronts as widescreen version

Processors

• Intel Atom E660 1.3 GHz,
2 GB RAM
• Intel Atom E640 1.0 GHz,
1 GB RAM

Chipset

Intel Controller Hub EG20T

NVRAM optional

512 KB, of which 128 KB can be
written within the buffer time

Operating system

• Windows Embedded Standard
2009 preinstalled, in combination
with CF card of 2 GB or more,
or solid-state drive, or hard drive
(optional)
• Windows XP Professional MUI
(in combination with solid-state
drive or hard drive; MUI:
Multi Language User Interface)
(optional)
• Windows Embedded Standard 7
32 bit,
preinstalled, in combination with
CF card
or solid-state drive (optional)
• Windows 7 Ultimate MUI 32 bit
(in combination with solid-state
drive; MUI: Multi Language User
Interface) (optional)
• Linux 1) (project-specific,
on request)
Others on request project-specifically

Power supply

• 24 V DC (20.4 V ... 28.8 V)
• Isolated
• With buffering of temporary power
failures: max. 10 ms
• Line side switch
• With power failure indication
by means of Power Fail signal

Drives
FlashDrive

Optional; replaceable, accessible,
diagnosable
• 2 GB
• 4 GB
• 8 GB
• 16 GB

Solid-state drive (SSD)

Optional
• 50 GB SATA, High Endurance, 2.5"
• 80 GB SATA, Standard, 2.5"

CD/DVD/Floppy

Via USB (not included in scope of
delivery)

Interfaces
PROFINET

PROFINET RT via Standard Ethernet
controller

Ethernet

• 2 x 10/100/1000 Mbps (RJ 45)
• Two independent Intel Controllers:
Intel 82574L / Intel Controller Hub
EG20T
With teaming function

USB

V2.0, 3 x

Serial

COM1 (V.24)

Keyboard

Via USB (not included in scope of
delivery)

Mouse

Via USB (not included in scope of
delivery)

1)

Suitable for specific LINUX versions in accordance with the specifications
of the Siemens manufacturer's declaration "Suitable for LINUX", see
http://www.siemens.com/simatic-pc/suited-for-linux
(LINUX is a trademark of Linus Torvald).

Siemens ST 80 / ST PC · 2013

5/53

5

© Siemens AG 2013

PC-based Automation
SIMATIC Panel PC
SIMATIC IPC277D

■ Technical specifications (continued)
SIMATIC IPC277D

SIMATIC IPC277D

Monitoring functions
Temperature

Monitoring functions
• Processor temperature
• Motherboard
Messages can be evaluated by the
application program
• Monitoring of program execution
• Monitoring time can be parameterized in software
• Can be parameterized for a fault or
restart

Watchdog

Temperature

Yes

Watchdog

Yes

Mass storage

Yes

Ambient conditions
Vibration load during operation

Requirements according to:
IEC 61131-2,
tested according to:
IEC 60068-2-6, Test Fc
10-58: 0.0375 mm,
58-200: 9.8 m/s2, 10x /axis

• DiagBase
• SIMATIC IPC DiagMonitor

Shock loading during operation

Remote monitoring capability for:
• Watchdog
• Temperature
• Mass memory monitoring (SMART)
• System/Ethernet monitoring
(Heart Beat)
• Runtime meter

Requirements according to:
IEC 61131-2,
tested according to:
IEC 60068-2-27, test Ea,
50 m/s2

Relative humidity

Tested in accordance with
DIN IEC 68-78, DIN IEC 60068-2-30:
5% to 80% at 25 °C
(no condensation)

Maximum permissible installation
angle +/-

45° over vertical

Ambient temperature during operation

0 °C … +50° C in maximum configuration; no fan (19": 0 °C … +45 °C)

Messages can be evaluated by the
application program
Monitoring functions via the network

Communication:
• Ethernet interface (SNMP protocol)
• OPC for integration in
SIMATIC software
• Configuration of client/server
architectures
• Structure of log files
Supply voltage
Supply voltage

5

Certifications & standards
Approvals

CE, cULus (508),
marine approval available for
7" /9" /12", 15" /19" available soon:
GL, LRS, BV, DNV, ABS, ClassNK

EMC

CE, FFC A, 55022A, EN 61000-6-4,
EN 61000-6-2

24 V DC

SIMATIC IPC277D
Front panel

7" TFT Touch,
widescreen

9" TFT Touch,
widescreen

12" TFT Touch,
widescreen

15" TFT Touch,
widescreen

19" TFT Touch,
widescreen

800 x 480

800 x 480

1280 x 800

1280 x 800

1366 x 768

Touch pen, touch
protective films

Touch pen, touch
protective films

Touch pen, touch
protective films

Touch pen, touch
protective films

Touch pen, touch
protective films

Display
Resolution (W x H in pixels)
General features
Accessories
Type of operation
Function keys

No

No

No

No

No

Alphanumeric keyboard

No

No

No

No

No

Touch screen (analog/resistive)

Yes

Yes

Yes

Yes

Yes

USB port on the front

No

No

No

Yes

Yes

Centralized configuration

Yes

Yes

Yes

Yes

Yes

Distributed configuration

No

No

No

No

No

Mounting dimensions in centralized
configuration (W x H x D) in mm

197 x 141 x 71

251 x 166 x 71

310 x 221 x 66

396 x 291 x 73

465 x 319 x 73

Operator control unit (W x H) in mm

214 x 158

274 x 190

330 x 241

415 x 310

483 x 337

Weight

1500 g

1950 g

2750 g

4000 g

5700 g

Max. power loss
in maximum configuration

27 W

29 W

37 W

42 W

45 W

Design

Dimensions

5/54

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
SIMATIC Panel PC
SIMATIC IPC277D

■ Ordering data
Nanopanel PC SIMATIC IPC277D

Order No.

Order No.

6AV7881- 7 A 7 0 0 - 7 7 7 0

Accessories

Interfaces: 2 x Gbit LAN (RJ45),
1 x serial (COM1), 3 x USB

Touch protective films 7" 1)

6AV2124-6GJ00-0AX0

Touch protective films 9" 1)

6AV2124-6JJ00-0AX0

Operating unit
• Touch 7" TFT
• Touch 9" TFT
• Touch 12" TFT
• Touch 15" TFT, front USB interface
• Touch 19" TFT, front USB interface

Touch protective films 12" 1)

6AV2124-6MJ00-0AX0

Touch protective films 15" 1)

6AV2124-6QJ00-0AX0

Touch protective films 19" 1)

6AV2124-6UJ00-0AX0

Bracket clamp, long
for 15", 19" and 22" widescreen,
Comfort Panels, IPC, Flat Panel
monitors and Thin Client (except
SCD1900 19" widescreen)

6AV6671-8XK00-0AX4

Touch pen
Captive pen for operation of the
touch devices, mounting of the support on the control cabinet or directly
on the PRO unit

6AV7672-1JB00-0AA0

Processors / memory configuration /
NVRAM
• Atom E640 (1.0 GHz), 1 GB RAM
• Atom E640 (1.0 GHz), 1 GB RAM,
NVRAM
• Atom E660 (1.3 GHz), 2 GB RAM
• Atom E660 (1.3 GHz), 2 GB RAM,
NVRAM
Drives
• Without drive, with CF slot
• 2 GB SIMATIC PC CompactFlash
• 4 GB SIMATIC PC CompactFlash
• 8 GB SIMATIC PC CompactFlash
• 16 GB SIMATIC PC CompactFlash
• 50 GB Solid-State Drive SATA
(High Endurance)
• 80 GB Solid-State Drive SATA
(Standard)
Operating system
• Without operating system
• WES 2009 preinstalled
(CF from 2 GB/SSD)
• XP-Prof. MUI preinstalled on SSD
• WES 7 32 bit preinstalled
(CF from 4 GB/SSD)
• Windows 7 MUI 32 bit preinstalled
on SSD
Software bundles
• Without RTX/HMI software
• RTX: WinAC RTX 2010
• RTX-F: WinAC RTX F 2010
• HMI: WinCC RT Advanced 128 PT
• HMI: WinCC RT Advanced 512 PT
• HMI: WinCC RT Advanced
2048 PT
• HMI/RTX: RT 128 PT
• HMI/RTX: RT 512 PT
• HMI/RTX: RT 2048 PT
• HMI/RTX-F: RT 128 PT
• HMI/RTX-F: RT 512 PT
• HMI/RTX-F: RT 2048 PT

1
2
3
4
5

A
B
E
F

1)

0
1
2
3
4
7

10 units per packing unit

Please be sure to note:
The IPC277D with bundled software is always supplied with
inserted CF card.
The licenses are on the supplied USB flash drive.

8

A
B
C
D
E

5
A
B
C
F
G
H
M
N
P
R
S
T

Siemens ST 80 / ST PC · 2013

5/55

© Siemens AG 2013

PC-based Automation
SIMATIC Panel PC
SIMATIC IPC277D

■ Dimensional drawings

141.5

G_ST80_XX_00468

38

72.6

6.2

276

2.3

196

308

99.5

10.5

310

129.5
32.5

4.8

164

190

SIMATIC IPC277D 12" version

289
141.5

2.3

177.6

66.4

G_ST80_XX_00466

77.3

71.1

36.5

330

SIMATIC IPC277D 7" version

274

SIMATIC IPC277D 9" version

5/56

Siemens ST 80 / ST PC · 2013

SIMATIC IPC277D 15" version

G_ST80_XX_00518

73
6.2

249

2,3

25.5

177.6

G_ST80_XX_00467

35.7

394
77.3

71.1

36.5

6.2

415

2.3

5

4.8

75.5

6.2

8.5

214

219

241

4.8

140

129.5

158

All dimensions in mm. For mounting cut-out see technical specifications.

© Siemens AG 2013

PC-based Automation
SIMATIC Panel PC
SIMATIC IPC277D

■ Dimensional drawings (continued)

■ More information
Further information can be found on the Internet at:

141.5
10.5

317

113,5

337

http://www.siemens.com/simatic-panel-pc

483

6.2

25.5

73

2,3

G_ST80_XX_00519

463

SIMATIC IPC277D 19" version

5

Siemens ST 80 / ST PC · 2013

5/57

© Siemens AG 2013

PC-based Automation
SIMATIC Panel PC
SIMATIC IPC477D

■ Overview

■ Technical specifications
SIMATIC IPC477D
General features

SIMATIC IPC477D: The powerful embedded Panel PC –
maintenance-free with versatile configuration
• Embedded PC platform with extremely high industrial compatibility for demanding tasks in the field of PC-based automation
• Maintenance-free (no rotating components such as fan and
hard disk)
• Rugged construction: The PC is resistant to even the harshest
mechanical stress and is extremely reliable in operation
• Compact design
• Battery-independent retentive memory onboard
• High degree of investment security
• Fast integration capability

5

The following front versions are available:
• Built-in versions
- 12" TFT Touch
- 15" TFT Touch
- 15" TFT Touch/Key
- 19" TFT Touch
- 22" TFT Touch

5/58

Siemens ST 80 / ST PC · 2013

Supply voltage1)

• 24 V DC (-20 % / +20 %) 1)
• 100 - 240 V AC (-15 % / +20 %);
50 - 60 Hz

Brief voltage interruption
in accordance with NAMUR

• Min. 20 ms (DC)
• Min. 20 ms (AC); max. 10 events
per hour; min. 1 s recovery time

Power consumption (DC) of devices
(without expansions):
• 12" display
• 15" display
• 19" display
• 22" display

55 W
56 W
65 W
74 W

Additional power consumption of
devices with expansions:
• DVD drive
• PCIe card

1W
5W

Processor

• Intel Celeron 827E 1.4 GHz;
1.5 MB SLC or
• Intel Core i3-3217UE 1.6 GHz;
3 MB SLC or
• Intel Core i7-3517UE 1.7 GHz;
4 MB SLC

Main memory

• SO-DIMM module;
1024 MB DDR3-SDRAM or
• SO-DIMM module;
2048 MB DDR3-SDRAM or
• SO-DIMM module;
4096 MB DDR3-SDRAM or
• SO-DIMM module;
8192 MB DDR3-SDRAM

Buffer memory 2)

512 KB MRAM

Drive and storage media
SATA drive

1 slot

Solid-state drive

• 1 x ≥ 50 GB; 2.5" SATA-SSD,
high endurance or
• 1 x ≥ 80 GB; 2.5" SATA-SSD,
standard or
• 1 x ≥ 160 GB; 2.5" SATA-SSD,
standard

Hard disk drive (HDD)

• 1 x ≥ 250 GB, 2.5"-SATA-HD

CFast card

•
•
•
•

DVD drive, RW

1 slot for devices with expansion

2 GB or
4 GB or
8 GB or
16 GB

1)

The generation of the supply voltage by the line-side power supply
must be realized as safety extra-low voltage with safe electrical isolation,
isolated according to IEC 60364 4 41, or as SELV according to
IEC/UL/EN/DIN-EN 60950-1.

2)

For devices with retentivity.

© Siemens AG 2013

PC-based Automation
SIMATIC Panel PC
SIMATIC IPC477D

■ Technical specifications (continued)
SIMATIC IPC477D

Display, resolution

SIMATIC IPC477D
Ethernet 3)

Graphics

• 2 x RJ45 connection,
Intel 82579LM and Intel 82574L
10/100/1000 Mbps, electrically
isolated, teaming-capable 4)

• 12" screen diagonal with LED
backlighting, resolution
1280 × 800 pixels, WXGA
(Wide XGA)
• 15" screen diagonal with LED
backlighting, resolution
1280 × 800 pixels,
WXGA(Wide XGA)
• 19" screen diagonal with LED
backlighting, resolution
1366 x 768 pixels
• 22" screen diagonal with LED
backlighting, resolution
1920 x 1080 pixels

Slot for PCIe expansion cards

Degree of protection

Resistive Tyco Elotouch controller
ELO CTR-2216SU-AT-CHP-00, touch
screen, analog resistive, touch force
with test pen of 2 mm diameter: 5 N

• IP 20 to IEC 60529 (enclosure)
• IP 65 (front)

Quality assurance

In accordance with ISO 9001

Backlighting (MTBF)

LED

Emitted interference S

EN 61000-6-4; CISPR 22 Class A;
FCC Class A

Half brightness life time, typical

Min. 50000 h at 50 °C,
50% brightness

Immunity with regard to conducted
interference on the supply lines

Graphics controller

• Intel HD 2000 or
• Intel HD 4000

Graphics memory

• 32 … 512 MB shared memory

• ± 2 kV to IEC 61000-4-4; burst
• ± 1 kV to IEC 61000-4-5;
surge symmetrical
• ± 2 kV to IEC 61000-4-5; surge
asymmetrical

Resolutions, frequency, colors

• DVI-I: 640 x 480 … 1920 x 1200,
60 Hz
• DP display port:
1920 x 1200, 60 Hz

Noise immunity on signal lines

• ± 2 kV to IEC 61000-4-4; burst,
length > 3 m
• ± 1 kV to IEC 61000-4-4; burst,
length < 3 m
• ± 2 kV to IEC 61000-4-5;
symmetrical surge, length > 30 m

Immunity to static discharge

• ± 6 kV, contact discharge
at the front to IEC 61000-4-2
• ± 4 kV contact discharge
at the rear to IEC 61000-4-2
• ± 8 kV air discharge
to IEC 61000-4-2

Immunity to high radio frequency
interference

• 10 V/m, 80 … 1000 MHz
80 % AM to IEC 61000-4-3
• 1 V/m, 2 … 2.7 GHz
• 3 V/m, 2 … 2.7 GHz
• 10 V, 10 kHz … 80 MHz to
IEC 61000-4-6

Immunity to magnetic fields

• 100 A/m, 50/60 Hz
to IEC 61000-4-8

Touch controller

or
• For PROFINET versions:
1 x Ethernet
Only for device with expansions:
1 x PCIe-x4 expansion card can be
used, max. permissible power loss:
5W
Degree of protection

Electromagnetic compatibility

Interfaces
COM 1 and COM 2

RS 232, max. 115 kbps, 9-pin,
sub-D connector

DVI

Connection of VDUs
with DVI connection

Display port (DPP)

Connection of VDUs
with DPP connection

Keyboard

Connection via USB port

Mouse

Connection via USB port

USB

• Rear of device:
4 x USB 3.0, max. 2 high-current
at the same time
• Front of device (only with IPC477D
with 15", 19" or 22" display):
1 x USB 2.0, high-current

PROFIBUS/MPI

• Transmission rate
• Operating modes

PROFINET

9-pole, 2 rows, electrically isolated,
Sub-D socket, compatible with
CP 5622
9.6 Kbps … 12 Mbps
DP master: DP-V0,
DP-V1 with SOFTNET-DP
DP slave: DP-V0,
DP-V1 with SOFTNET-DP slave
3 x RJ45 interface, CP 1616
compatible onboard interface
based on ERTEC 400
10/100 Mbps, electrically isolated

Weight
• IPC477D, touch device,
12" display
• IPC477D, touch device,
15" display
• IPC477D, touch/key device
(without expansions),
15" display
• IPC477D, touch device,
19" display
• IPC477D, touch device,
22" display

Approx. 3200 g
Approx. 4920 g
Approx. 5750 g

Approx. 6400 g
Approx. 7000 g

3)

For unambiguous labeling, the Ethernet ports are numbered on the
enclosure. The numbering by the operating system can differ.

4)

Teaming can be set and initiated in the configuration interface. In teaming
operation, jumbo frames, e.g. for the camera application, are not
supported

Siemens ST 80 / ST PC · 2013

5/59

5

© Siemens AG 2013

PC-based Automation
SIMATIC Panel PC
SIMATIC IPC477D

■ Ordering data
SIMATIC IPC477D

Order No.
1)

6AV7240- 7 7 7 7 7 - 7 7 A 0

Processor and fieldbus:
• Celeron U827E
(1C/1T, 1.4 GHz, 1.5 MB cache);
2 x Gigabit Ethernet (IE/PN)
• Celeron U827E
(1C/1T, 1.4 GHz, 1.5 MB cache);
2 x Gigabit Ethernet (IE/PN);
PROFIBUS DP12
• Core i3-3217UE
(2C/4T, 1.6 GHz, 3 MB cache);
2 x Gigabit Ethernet (IE/PN)
• Core i3-3217UE
(2C/4T, 1.6 GHz, 3 MB cache);
2 x Gigabit Ethernet (IE/PN);
PROFIBUS DP12
• Core i3-3217UE
(2C/4T, 1.6 GHz, 3 MB cache);
1 x Gigabit Ethernet (IE/PN);
1 x PROFINET (IRT, 3 ports)
• Core i7-3517UE
(2C/4T, 1.7 (2.8) GHz,
3 MB cache);
2 x Gigabit Ethernet (IE/PN)
• Core i7-3517UE
(2C/4T, 1.7 (2.8) GHz,
3 MB cache); 2 x Gigabit Ethernet
(IE/PN); PROFIBUS DP12
• Core i7-3517UE
(2C/4T, 1.7 (2.8) GHz,
3 MB cache); 1 x Gigabit Ethernet
(IE/PN); 1 x PROFINET
(IRT, 3 ports)

5

Operator control unit:
• 12" Touch (1280 x 800)
(caution, restrictions regarding
options: HDD, PCI, AC, DVD)
• 15" Touch (1280 x 800)
with front USB
• 15" Touch/Key (1280 x 800)
with front USB
• 19" Touch (1366 x 768)
with front USB
• 22" Touch (1920 x 1080)
with front USB
Main memory/NVRAM:
• 1 GB
• 2 GB
• 4 GB
• 8 GB
• 1 GB and NVRAM
• 2 GB and NVRAM
• 4 GB and NVRAM
• 8 GB and NVRAM
1)

Order No.

Expansions/interface:
• 1 x RS 232, without PCIe
• 1 x RS 232 and 1 x PCIe
• Second RS 232, without PCIe
• Second RS 232 and 1 x PCIe

0

1

Operating system:
• Without operating system
• Windows Embedded Standard 7
SP1, English, 32-bit
• Windows 7 Ultimate SP1, 32-bit,
MUI (Eng, Ger, Fr, It, Sp)
• Windows 7 Ultimate SP1, 64-bit,
MUI (Eng, Ger, Fr, It, Sp)

3

4

5

Externally accessible mass storage
(without operating system):
• Without external mass storage
• CFAST 2 GB, without software
• CFAST 4 GB
• CFAST 8 GB
• CFAST 16 GB
• DVD

6

7

Internal mass storage:
• Without internal mass storage
• CFAST 2 GB
• CFAST 4 GB
• CFAST 8 GB
• CFAST 16 GB
• SSD 50 GB High Endurance
• SSD 80 GB Standard
• HDD 250 GB
• DVD
• SSD 50 GB high endurance
with DVD
• SSD 80 GB standard with DVD

8

A

B
C
D
E

• SSD 160 GB standard with DVD
• HDD min. 250 GB with DVD
A
B
C
D
J
K
L
M

Built to order versions with a delivery time of max. 15 working days and
with identified repair.

5/60

Siemens ST 80 / ST PC · 2013

SIMATIC IPC477D
(continued)

1)

6AV7240- 7 7 7 7 7 - 7 7 A 0

0
1
3
4
0
4
6
7

0
1
2
3
4
6
A
B
C
D
E
G
H
K
L
M
N
P
Q

© Siemens AG 2013

PC-based Automation
SIMATIC Panel PC
SIMATIC IPC477D

■ Ordering data

Order No.

SIMATIC IPC477D 1)
(continued)

Order No.

6AV7240- 7 7 7 7 7 - 7 7 A 0

SIMATIC software preinstalled
(bundles):
• Without SIMATIC software
• WinAC RTX 2010 2)
• WinCC RT Advanced 128 PT
• WinCC RT Advanced 512 PT
• WinCC RT Advanced 2048 PT
• WinCC RT Advanced 4096 PT
• WinCC RT Advanced 128 PT,
WinAC RTX 2)
• WinCC RT Advanced 512 PT,
WinAC RTX 2)
• WinCC RT Advanced 2048 PT,
WinAC RTX 2)
• WinCC RT Advanced 4096 PT,
WinAC RTX 2)
• WinAC RTX 2010 F 2)
• WinCC RT Advanced 128 PT,
WinAC RTX F 2)
• WinCC RT Advanced 512 PT,
WinAC RTX F 2)
• WinCC RT Advanced 2048 PT,
WinAC RTX F 2)
• WinCC RT Advanced 4096 PT,
WinAC RTX F 2)

SIMATIC IPC477D 1)
(continued)

6AV7240- 7 7 7 7 7 - 7 7 A 0

Power supply:
• 24 V DC industrial power supply
• 110/230 V AC industrial power
supply with Namur; no power
cable
• 110/230 V AC industrial power
supply with Namur; European
power cable
• 110/230 V AC industrial power
supply with Namur; US power
cable
• 110/230 V AC industrial power
supply with Namur; Chinese power
cable
• 110/230 V AC industrial power
supply with Namur; Italian power
cable
• 110/230 V AC industrial power
supply with Namur; Swiss power
cable
• 110/230 V AC industrial power
supply with Namur; UK power
cable
• 24 V DC industrial power supply
and TPM (not for China and
Russia)

A
B
C
D
E
F
J
K
L
M
N
P
Q
R
S

0
1

2

3

4

5

6

7

8

1)

Built to order versions with a delivery time of max. 15 working days and
with identified repair.

2)

Only with main memory and NVRAM.

■ Dimensional drawings
All dimensions in mm. For mounting cut-out see technical specifications.

194.6

288.9

310
11

SIMATIC IPC477D 12" Touch device

75.5
6.2

82.2

2.3
G_ST80_XX_00524

11.2

2.3

81.6

393.9
372.4
G_ST80_XX_00523

6.2

38

11

415

25.5

330
308
276.4

68.2

39.1

4.6

241

219
178.7

5

SIMATIC IPC477D 15" Touch device

Siemens ST 80 / ST PC · 2013

5/61

© Siemens AG 2013

PC-based Automation
SIMATIC Panel PC
SIMATIC IPC477D

194.6
289
68.2

310

194.6
82.2

337

316.9

■ Dimensional drawings (continued)

483
483
426.9
372.4

38.2

448
372.4

SIMATIC IPC477D 15" Touch/Key device

■ More information
Additional information is available in the Internet under:

103.8

5

194.6

380

360

http://www.siemens.com/simatic-panel-pc

560

84.2

540
372.4

SIMATIC IPC477D 22" Touch device

5/62

Siemens ST 80 / ST PC · 2013

81.6

G_ST80_XX_00526

25.5

6.2

75.5

2.3

G_ST80_XX_00527

75.5
6.2

G_ST80_XX_00525

81.6

75.5
25.5

6.2

SIMATIC IPC477D 19" Touch device

81.6

2.3

2.3

25.5

45.7

© Siemens AG 2013

PC-based Automation
SIMATIC Panel PC
SIMATIC HMI IPC477C

■ Overview
SIMATIC HMI IPC477C: The powerful embedded Panel PC –
maintenance-free with versatile configuration
• Embedded PC platform with extremely high industrial compatibility for demanding tasks in the field of PC-based automation
• Maintenance-free (no rotating components such as fan and
hard disk)
• Rugged construction: The PC is resistant to even the harshest
mechanical stress and is extremely reliable in operation
• Compact design (only 61-69 mm installation depth for 12"-19")
• Battery-backed retentive memory onboard
• High degree of investment security
• Fast integration capability
The following front versions are available:
• Built-in versions
- 12" and 15" TFT Touch
- 12" and 15" TFT keypad
- 19" Touch
• Support arm versions
- PRO 15" and PRO 19" Touch
- Fully enclosed device with degree of protection IP65 for
mounting on a support arm/stand

■ Technical specifications
6AV7 884-1....-...0

6AV7 884-2....-...0

6AV7 884-3....-...0

SIMATIC HMI IPC477C

SIMATIC HMI IPC477C

SIMATIC HMI IPC477C

Operator control and monitoring
Accessory components

Slide-in keyboard labels

Touch protective foil
(not for Inox front)

Slide-in keyboard labels

Display
Screen diagonal

12 in

15 in

15 in

Resolution (pixels)
• Resolution (WxH in pixel)

800 x 600

1024 x 768

1024 x 768

General features
• Front panel

12" TFT Key

15" TFT Touch

15" TFT Key

Backlighting
• MTBF backlighting (at 25 °C)

about 50,000 hours

50000 h

about 50,000 hours

Control elements
Function keys

36

No

36

Mouse, at front

Yes

No

Yes

Keyboard fonts
• Alphanumeric keyboard

Yes

No

Yes

Touch operation
• Design as touch screen
- Touch screen (analog/resistive)

No
No

Yes
Yes

No
No

Installation type/mounting
central design

Yes

Yes

Yes

Distributed design

No

No

No

24 V DC: Max. 60 W
(incl. USB interfaces)

140 W max.
(15 W included per slot)

24 V DC: Max. 60 W
(incl. USB interfaces)

450 mm x 290 mm/75 mm device
depth

450x290 / 108 (incl. optical drive)

450 x 321 x 75

No drive planned.

No drive planned.

No drive planned.

6.6 kg

7 kg

7.2 kg

Power losses
Power loss in full configuration
Dimensions
Mounting cutout (W x H x D)
additional mounting depth
(optical drive)
Weight
Panel PC in central design, approx.

Siemens ST 80 / ST PC · 2013

5

5/63

© Siemens AG 2013

PC-based Automation
SIMATIC Panel PC
SIMATIC HMI IPC477C

■ Ordering data

Order No.

Order No.

SIMATIC HMI IPC477C and
IPC477C PRO
(built to order versions with a delivery time of max. 15 working days
and with original part repair, if not
preferred type).
SIMATIC HMI IPC477C

SIMATIC HMI IPC477C PRO
(continued)

6AV7884- 7 A 7 7 7 - 7 7 7 0

SIMATIC HMI IPC477C PRO

0
1
2
3
5
6AV7883- 7 A 7 7 7 - 7 7 7 0

Embedded and fan-free with IP65
enclosure protected all-round;
5 x USB (500 mA),
of which 1 x on the front,
battery-backed retentive
memory onboard,
24 V DC power supply
with On/Off switch
• 15" TFT Touch (IP65 enclosure)
• 19" TFT Touch (IP65 enclosure)

5

Processors and fieldbus
• Celeron M 1.2 GHz,
2 x PROFINET (IE) 1)
• Celeron M 1.2 GHz,
2 x PROFINET (IE),
1 x PROFIBUS DP 12 1)
• Core2 Solo 1.2 GHz,
2 x PROFINET (IE) 1)
• Core2 Solo 1.2 GHz,
2 x PROFINET (IE),
1 x PROFIBUS 1)
• Core2 Solo 1.2 GHz,
1 x PROFINET (IE),
1 x PROFINET (RT/IRT) (3 ports)
• Core2 Duo 1.2 GHz,
2 x PROFINET (IE) 1)
• Core2 Duo 1.2 GHz,
2 x PROFINET (IE),
1 x PROFIBUS 1)
• Core2 Duo 1.2 GHz,
1 x PROFINET (IE),
1 x PROFINET (RT/IRT) (3 ports)

Main memory (DDR3 RAM), 1 bank
• 1 GB
• 2 GB 1)
• 4 GB

1
2
3

Second mass storage
(installed and formatted)
• Without1)
• CompactFlash 2 GB 1)
• CompactFlash 4 GB 1)
• CompactFlash 8 GB 1)
• CompactFlash 16 GB 1)
• SSD High Endurance, min. 50 GB
• SSD Standard, min. 80 GB
(not for PRO version)

Embedded and fan-free
5 x USB (500 mA),
of which 1 x on the front,
battery-backed retentive
memory onboard,
24 V DC power supply
with On/Off switch
Front Panels
• 12" TFT Touch 1)
• 12" TFT Key
• 15" TFT Touch 1)
• 15" TFT Key
• 19" TFT Touch 1)

6AV7883- 7 A 7 7 7 - 7 7 7 0

6
7
A
B

D
E

F

0
2
3
4
5
6
7

Mass storage (built-in, operating
system pre-installed)
• CompactFlash 2 GB
(only with Windows Embedded
Standard 2009) 1)
• CompactFlash 4 GB 1)
• CompactFlash 8 GB 1)
• CompactFlash 16 GB 1)
• SSD High Endurance, min. 50 GB
• SSD Standard, min. 80 GB
(not for PRO version)

2

3
4
5
6
7

Operating system
(preinstalled and activated)
• Windows Embedded Standard
2009 1)
• Windows XP Professional
Multi-Language, only with SSD;
without SIMATIC software
• Windows Embedded Standard 7
(only with CF > 4 GB or SSD and
from 2 GB RAM)
• Windows 7 Ultimate, MUI
(Eng, Ger, Fr, It, Sp) only with SSD;
without SIMATIC software
SIMATIC HMI IPC477C (PRO)
with SIMATIC software

BA
DA

E A

GA

See Embedded bundles / Packages
for industrial PCs

G
H

J

1)

Preferred types with replacement devices in exchange

Note:
Ready-to-use SIMATIC IPC477C (PRO) as bundles can be found
under "Embedded bundles".
Software packages with SIMATIC WinCC flexible, SIMATIC
WinCC RT Advanced, SIMATIC WinCC, SIMATIC WinCC RT
Professional, and SIMATIC WinAC RTX (F) can be ordered
together with the SIMATIC IPC with a price advantage.
More information under "Embedded bundles / Packages for
industrial PCs".

5/64

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
SIMATIC Panel PC
SIMATIC HMI IPC477C

■ Ordering data

Order No.

Order No.

Accessories
Protective film
for Panel PCs 477/577/677
For protecting the touch screen
against dirt/scratches
• for 12" Touch
• for 15" Touch (not for PRO)
• for 19" Touch
Labeling membranes
for Panel PCs 477/577/677
For labeling soft keys and function
keys, blank, supplied in sets of 10

6AV7671-2BA00-0AA0
6AV7671-4BA00-0AA0
6AV7672-1CE00-0AA0

Touch pen
Captive pen for operation of the
touch devices, mounting of the support on the control cabinet or directly
on the PRO unit

6AV7672-1JB00-0AA0

Expansion components

From page 5/153

6AV7672-0DA00-0AA0

Please be sure to note:
The HMI IPC477C is delivered as standard with an inserted
CF card. The licenses are on the supplied USB flash drive.
Note:
Further embedded versions based on IPC427C and Embedded
Controller (mEC) are listed under SIMATIC PC-based Control.

■ Dimensional drawings

19.5

70.8

60.3 10.5

328
447.2

37.3

65.1

70.8

44

60.3

10.5

All dimensions in mm. For mounting cut-out see technical specifications.

328
366

482.6

G_ST80_XX_00396

59.15

4.8

207.5

288.3

G_ST80_XX_00395

4.8

310.3

207.5
59.15

SIMATIC HMI IPC477C 12" Key version

5

400

288.3

235

310.3

465

SIMATIC HMI IPC477C 12" Touch version

Siemens ST 80 / ST PC · 2013

5/65

© Siemens AG 2013

PC-based Automation
SIMATIC Panel PC
SIMATIC HMI IPC477C

10.5

74.6
328

88.1

447.2

40.1

328
447.2

43.5

65.1

64.1

69.8

59.3 10.5

■ Dimensional drawings (continued)

482.6
482.6

465

SIMATIC HMI IPC477C 19" Touch version

■ More information
Additional information is available in the Internet under:
http://www.siemens.com/simatic-panel-pc

5/66

Siemens ST 80 / ST PC · 2013

G_ST80_XX_00399

104

4.8

400
235

378
207.5

482.6
465

207.5

288.3

4.8

G_ST80_XX_00398

G_ST80_XX_00397

40.9

81

70.5

5

328
447.2

59.1

310.3
4.8

74.7

SIMATIC HMI IPC477C 15" Touch version

10.5

SIMATIC HMI IPC477C 15" Key version

88.1

235

207.5

354.8
235

319.4

465

© Siemens AG 2013

PC-based Automation
SIMATIC Panel PC
SIMATIC HMI IPC577C

■ Overview
Rugged, expandable industry PC for demanding tasks in the
area of PC-based automation with various control units
(front panels):
• Rugged and compact design for industrial use
• Full PC openness
- Windows Embedded Standard or Windows XP Professional,
or without operating system
- CF card, HDD, SSD
- DVD drive
• Expandable using a PCI slot
• Optionally with PROFIBUS or PROFINET (RT/IRT) onboard
• Installation-compatible with Panel PC 577B
- Touch screen control units with 12", 15" and 19" TFT display
- 12" and 15" TFT Key
• High degree of investment protection

■ Technical specifications
6AV7 885-0....-....
SIMATIC HMI
IPC577C

6AV7 885-1....-....
SIMATIC HMI
IPC577C

6AV7 885-2....-....
SIMATIC HMI
IPC577C

6AV7 885-3....-....
SIMATIC HMI
IPC577C

6AV7 885-5....-....
SIMATIC HMI
IPC577C

Operator control and monitoring
Accessory components

Touch protective foil

Slide-in keyboard
labels

Touch protective foil

Slide-in keyboard
labels

Touch protective foil

Display
Screen diagonal

12 in

12 in

15 in

15 in

19 in

Resolution (pixels)
• Resolution (WxH in pixel)

800 x 600

800 x 600

1024 x 768

1024 x 768

1280 x 1024

General features
• Front panel

12" TFT touch display

12" TFT Key

15" TFT touch display

15" TFT Key

19" TFT Touch

Backlighting
• MTBF backlighting (at 25 °C)

about 50,000 hours

about 50,000 hours

about 50,000 hours

about 50,000 hours

about 50,000 hours

Control elements
Function keys

No

36

No

36

No

Mouse, at front

No

Yes

No

Yes

No

Keyboard fonts
• Alphanumeric keyboard

No

Yes

No

Yes

No

Touch operation
• Design as touch screen
- Touch screen (analog/resistive)

Yes
Yes

No
No

Yes
Yes

No
No

Yes
Yes

Installation type/mounting
central design

Yes

Yes

Yes

Yes

Yes

Distributed design

No

No

No

No

No

24 V DC: Max. 80 W
(incl. USB interfaces)

24 V DC: Max. 80 W
(incl. USB interfaces)

24 V DC: Max. 80 W
(incl. USB interfaces)

24 V DC: Max. 80 W
(incl. USB interfaces)

24 V DC: Max. 80 W
(incl. USB interfaces)

368 x 290 x 115

450 x 290 x 115

450 x 290 x 120

450 x 321 x 115

450 x 380 x 125

23 mm

23 mm

23 mm

23 mm

23 mm

8.1 kg

8.6 kg

9 kg

9.3 kg

11.6 kg

Power losses
Power loss in full configuration
Dimensions
Mounting cutout (W x H x D)
additional mounting depth
(optical drive)
Weight
Panel PC in central design, approx.

Siemens ST 80 / ST PC · 2013

5/67

5

© Siemens AG 2013

PC-based Automation
SIMATIC Panel PC
SIMATIC HMI IPC577C

■ Ordering data
SIMATIC HMI IPC577C

Order No.
6AV7885- 7 7 7 7 7 - 7 7 7 7

Front Panels
• 12" TFT Touch
• 12" TFT Key
• 15" TFT Touch
• 15" TFT Key
• 19" TFT Touch
Mainboards
(processor with fieldbus interfaces)
• Celeron M 1.2 GHz, 1 MB cache,
800 MHz FSB
- with PROFINET
(Industrial Ethernet);
2x LAN 1 Gbps
• Core2 Solo 1.2 GHz, 3 MB cache,
800 MHz FSB
- with PROFINET
(Industrial Ethernet),
2x LAN 1 Gbps
- with PROFIBUS DP12/MPI
(CP5611-compatible),
2x LAN 1 Gbps
- with PROFINET (RT/IRT) 3 ports,
1x LAN 1 Gbps
• Core2 Duo 1.86 GHz, 6 MB cache,
1066 MHz FSB
- with PROFINET
(Industrial Ethernet),
2x LAN 1 Gbps
- with PROFIBUS DP12/MPI
(CP5611-compatible),
2x LAN 1 Gbps
- with PROFINET (RT/IRT) 3 ports,
1x LAN 1 Gbps

5

RAM
• 1 GB RAM, DDR3
• 2 GB RAM, DDR3
• 4 GB RAM, DDR3
Second mass storage and/or
drive (formatted without operating
system)
• No second mass storage/drive
• DVD-RW drive
• HDD + DVD-RW drive
• SSD 50 GB High Endurance+
DVD-RW drive
• SSD 80 GB Standard+
DVD-RW drive
• SSD 50 GB High Endurance
• SSD 80 GB Standard
• HDD min. 250 GB
1)

Order No.
SIMATIC HMI IPC577C
(continued)
First mass storage (formatted,
optionally with operating system):
• Without
• HDD min. 250 GB (not if
2nd mass storage HDD or SSD)
• 2 GB CompactFlash
• 4 GB CompactFlash
• 8 GB CompactFlash
• 16 GB CompactFlash
• SSD 50 GB High Endurance (not if
2nd mass storage HDD or SSD)
• SSD 80 GB Standard (not if 2nd
mass storage HDD or SSD)

0
1
2
3
5

AA

Operating system
(pre-installed on first mass storage)
• Without operating system
• Windows Embedded Standard
• Windows XP Professional
Multi-Language 1)
• Windows Embedded Standard 7
• Windows 7 Ultimate
Multi-Language 1)

AD

A E

A F

Expansion (software)
• Without expansion
• IPC DiagMonitor V4.3 enclosed
• IPC Image & Partition Creator
• IPC DiagMonitor V4.3 and Image &
Partition Creator V3.2 enclosed

AK

A L

AM

1
2
3

0
1
2
3
4
6
7
8

Multi-Language means: D/E/F/I/SP/CHIN traditional/CHIN simplified/
Korean/Japanese

6AV7885- 7 7 7 7 7 - 7 7 7 7

0
1
2
3
4
5
6
7

A
B
D
E
G

A
B
C
D

Power supply
• 100/240 V AC industrial power
supply with Namur
• 100/240 V AC industrial power
supply with Namur; power cable
for Europe
• 100/240 V AC industrial power
supply with Namur; power cable
for the USA
• 100/240 V AC industrial power
supply with Namur; CN power
cable
• 100/240 V AC industrial power
supply with Namur; IT power cable
• 100/240 V AC industrial power
supply with Namur; CH cable
• 100/240 V AC industrial power
supply with Namur; UK cable
• 24 V DC industrial power supply

Siemens ST 80 / ST PC · 2013

2

3

4

5
6
7
8

Note:
Software Packages with SIMATIC WinCC flexible, SIMATIC
WinCC and SIMATIC WinAC RTX (F) can be ordered together
with the SIMATIC IPC with a price advantage.
More information under "Embedded Bundles / Packages for
industrial PCs".

5/68

1

© Siemens AG 2013

PC-based Automation
SIMATIC Panel PC
SIMATIC HMI IPC577C

■ Ordering data

Order No.

Order No.

Accessories
Protective film
for SIMATIC HMI IPC577C
For protecting the touch screen
against dirt/scratches,
set of 10
• for 12" Touch
• for 15" Touch
• for 19" Touch
Labeling strips for Key devices
For labeling soft keys and function
keys, blank, supplied in sets of 10

6AV7671-2BA00-0AA0
6AV7671-4BA00-0AA0
6AV7672-1CE00-0AA0

Touch pen
Captive pen for operation of the
touch devices, mounting of the
support on the control cabinet

6AV7672-1JB00-0AA0

Expansion components

From page 5/153

Communication components

From page 5/186

6AV7672-0DA00-0AA0

■ Dimensional drawings

83.8

104.4

70.8

104.4

10.5

10.5

All dimensions in mm. For mounting cut-out see technical specifications.

354.4
482.6
465

SIMATIC HMI IPC577C 12" Key version

5
G_ST80_XX_00403

229
55.6

G_ST80_XX_00402

288.3

310.3

229
48.7

288.3

235

310.3

400

SIMATIC HMI IPC577C 12" Touch version

Siemens ST 80 / ST PC · 2013

5/69

© Siemens AG 2013

PC-based Automation
SIMATIC Panel PC
SIMATIC HMI IPC577C

94

103.4

82.8

114.6

10.5

10.5

■ Dimensional drawings (continued)

87.6

108.2

328

5

482.6

55.6

SIMATIC HMI IPC577C 15" Touch version

■ More information
Additional information is available in the Internet under:
http://www.siemens.com/simatic-panel-pc

5/70

Siemens ST 80 / ST PC · 2013

G_ST80_XX_00405

288.3
229

235

310.3

465

G_ST80_XX_00406

102.4

229

400
235
G_ST80_XX_00404

71.2

SIMATIC HMI IPC577C 19" Touch version

10.5

SIMATIC HMI IPC577C 15" Key version

378

465

229

483

465

319.4

482.6

235

354.8

354.4

© Siemens AG 2013

PC-based Automation
SIMATIC Panel PC
SIMATIC HMI IPC677C

■ Overview

■ Technical specifications
SIMATIC HMI IPC677C
General features

SIMATIC HMI IPC677C: The high-end Panel PC –
with maximum performance, functional scope and
expansion capability
• Compact design
• High degree of investment security
• Fast integration capability
• Front panel versions:
- 12", 15" and 19" TFT Touch
- 12" and 15" TFT Key
- 15" TFT Touch INOX with stainless steel front for special
requirements, e.g. in the food, beverages and tobacco
industries

Processor

• Intel Core i7-610E
(2C/4T, 2.53 GHz, 4 MB L2,
Turbo Boost, VT-d)
• Intel Core i3-330E
(2C/4T, 2.13 GHz, 3 MB L2)
• Intel Celeron P4505
(2C/2T, 1.86 GHz, 2 MB L2)

Main memory

1 GB, optionally 2, 3, 4 or 8 GB or
2, 4 or 8 GB with ECC

Free slots for expansions

• 2 x PCI (slot with card retainer) or
1 x PCI and 1 x PCIe x16
• 1 x slot for CompactFlash Card
(accessible from outside)

Operating system

Different Windows operating
systems incl. Windows 7 Ultimate
64-bit

Power supply

24 V DC or 110/240 V AC
(autorange), 50/60 Hz

MTBF backlighting

Typ. 50 000 h (at 24 h continuous
operation, temperature-dependent)

Drives
Optical drives

Optional DVD±RW±R combo drive,
at the rear, operable from the side

Hard disk/mass storage

• 3.5" SATA hard disk ≥ 250 GB;
• optional 3.5" SATA hard disk
≥ 500 GB,
• Dual hard disk module
2 x ≥ 250 GB SATA as single
disk configuration or RAID1
preconfigured,
• 50 GB SSD (solid-state drive)

5

Siemens ST 80 / ST PC · 2013

5/71

© Siemens AG 2013

PC-based Automation
SIMATIC Panel PC
SIMATIC HMI IPC677C

■ Technical specifications (continued)
SIMATIC HMI IPC677C
Interfaces

SIMATIC HMI IPC677C
Certifications & standards

Graphics interface

DVI-I for additional display unit:
Color depth 32 bits

Connection for keyboard/mouse

USB / USB

Serial interface

COM1: 1 x V.24 (RS232)

PROFIBUS DP/MPI

Onboard, isolated, max. 12 Mbit/s,
compatible with CP 5611,
not upgradeable

PROFINET (IRT)

Onboard, 3 x RJ 45,
CP 1616-compatible,
not upgradeable

PROFINET (IE), Ethernet

Onboard, 2 x 10/100/1000 Mbit

USB

1 x on front, 4 x on rear,
USB 2.0 (500 mA)

Audio

Possible via USB (external)

Multimedia

No

Approvals

CE, cULus(508)
ATEX 22, UL Class 1 Div 2
(see front options)

Shipbuilding approval
(for configurations with CompactFlash
or SSD memory and without optical
drive)

•
•
•
•

Expansion components

Uninterruptible power supply (UPS),
SIMATIC NET communication
modules,
SIMATIC IPC DiagMonitor,
SIMATIC IPC Image & Partition
Creator,
SIMATIC IPC USB FlashDrive

GL - Germanische Lloyd
BV - Bureau Veritas
LR - Lloyds Register of Shipping
ABS - American Bureau of
Shipping
• DNV - Det Norske Veritas
• NKK - Nippon Kaiji Kyokai

Monitoring functions
Temperature

Yes

Watchdog

Yes

Ambient conditions

5

Degree of protection

IP65 (front) in accordance
with EN 60529 and NEMA 4

Vibration load during operation

Tested according to
DIN IEC 60068-2-6: 10 - 58 Hz:
0.075 mm, 58 to 500 Hz:
10 m/s² (1 g) 2)

Shock loading during operation

Tested according to
DIN IEC 60068-2-27: 50 m/s²
(5 g), 30 ms, 100 shocks

EMC

CE, FCC A, 55022A,
EN 61000-6-41), EN 61000-6-2

Ambient temperature
during operation

• 12"/15": 5 °C … +50 °C
in maximum configuration
• 19": 5 °C … +45 °C
in maximum configuration

Relative humidity

Tested according to
DIN IEC 60068-78,
DIN IEC 60068-2-30: 5% to 80%
at 25 °C (no condensation)

Maximum permissible installation
angle +/-

20° over vertical

5/72

Siemens ST 80 / ST PC · 2013

1)

61000-6-2 replaces 50082-2; 61000-6-4 replaces 50081-2

2)

Valid with CF or SSD; with HDD: 5 g/0.5 g

© Siemens AG 2013

PC-based Automation
SIMATIC Panel PC
SIMATIC HMI IPC677C

■ Ordering data
SIMATIC HMI IPC677C
Front panels
• 12" TFT Touch
• 12" TFT Key
• 15" TFT Touch
• 15" TFT Key
• 19" TFT Touch
Front options
• With front USB interface
• Without front USB interface
• INOX front, without front USB,
with 15" TFT Touch only
• 19" TFT Touch with ATEX 22 and
UL Class 1 Division 2 certification
Power supply
• 24 V DC
• 110/230 V AC,
power cable for Europe
• 110/230 V AC, without power cable
• 110/230 V AC, power cable for UK
• 110/230 V AC, power cable for CH
• 110/230 V AC,
power cable for the USA
• 110/230 V AC,
power cable for Italy
• 110/230 V AC,
power cable for China
Processor
• Intel Celeron 1.86 GHz
(2 Mbyte shared cache), 2 cores
• Intel Celeron 1.86 GHz
(2 MB shared cache),
2 cores, PROFIBUS MPI,
2 MB buffered SRAM
• Intel Celeron 1.86 GHz
(2 MB shared cache),
2 cores, PROFINET
(3 x RJ45, CP1616-compatible),
2 MB buffered SRAM
• Intel Core i3; 2.13 GHz
(3 MB shared cache),
2 cores, hyper-threading
• Intel Core i3; 2.13 GHz
(3 MB shared cache), 2 cores,
hyper-threading, PROFIBUS MPI,
2 MB buffered SRAM
• Intel Core i3; 2.13 GHz
(3 MB shared cache), 2 cores,
hyper-threading, PROFINET
(3 x RJ45, CP1616-compatible),
2 MB buffered SRAM
• Intel Core i7; 2.53 GHz
(4 MB shared cache), 2 cores,
hyper-threading, turbo boost
• Intel Core i7; 2.53 GHz
(4 MB shared cache), 2 cores,
hyper-threading, turbo boost,
PROFIBUS MPI,
2 MB buffered SRAM
• Intel Core i7; 2.53 GHz
(4 MB shared cache), 2 cores,
hyper-threading, turbo boost,
PROFINET (3 x RJ45,
CP 1616-compatible),
2 MB buffered SRAM

Order No.

Order No.

6AV789 7 - 7 7 7 7 7 - 7 7 7 7

Main memory
• 1 GB DDR3
• 2 GB DDR3
• 3 GB DDR3
• 4 GB DDR3
• 8 GB DDR3
• 2 GB DDR3 with ECC
• 4 GB DDR3 with ECC
• 8 GB DDR3 with ECC

0
1
2
3
4

3

0
1
2

4

3

6AV789 7 - 7 7 7 7 7 - 7 7 7 7

SIMATIC HMI IPC677C
(continued)

0
1
2
3
4
5
6
7

Mass storage
• 250 GB SATA hard disk
• 500 GB SATA hard disk
• RAID1 dual hard disk module
2 x 250 GB SATA, preconfigured
• Dual hard disk module
2 x 250 GB SATA
• 50 GB SSD
• Second CF card slot, internal,
empty (not with Windows XP or
Windows 7) instead of hard disk
or SSD
• Without mass memory

A
B
C
D
E
F
G

Optical drives
• without
• DVD±RW±R combo drive

H

A
B

C

D

E

F

G

H

0
1
2
3
4
5

8
0
1

Communication interfaces
• 2x PCI free
• 1x PCI, 1x PCIe (x16) free

A
B

Operating system
(preinstalled and activated)
• Without operating system
• Windows XP Professional
Multi-Language 1)
• Windows 7 Ultimate 32 Bit
Multi-Language 1)
• Windows Embedded Standard
on 8 GB CF card 2)
• Windows 7 Ultimate 64 Bit
Multi-Language 1)

A
B

D
E

Software expansion
• Without
• SIMATIC IPC DiagMonitor V4.3
enclosed
• SIMATIC IPC Image & Partition
Creator V3.2 enclosed
• SIMATIC IPC DiagMonitor V4.3,
Image & Partition Creator V3.2
enclosed
1)

Multi-Language means: D/E/F/I/SP/CHIN

2)

Only without RAID 1 option

0
1
2
3

Note:
J

Software Packages with SIMATIC WinCC flexible,
SIMATIC WinCC and SIMATIC WinAC RTX (F) can be ordered
together with the SIMATIC IPC with a price advantage.
More information under "Embedded Bundles / Packages for
industrial PCs".

Siemens ST 80 / ST PC · 2013

5

C

5/73

© Siemens AG 2013

PC-based Automation
SIMATIC Panel PC
SIMATIC HMI IPC677C

■ Ordering data

Order No.

Preferred versions
12" TFT Touch
with Windows XP Prof. MUI,
110/230 V AC power supply,
Core i3 2.13 GHz, 2 x PCI,
1 GB RAM, 250 GB HDD
DVD±R/RW burner, PROFIBUS/MPI,
NVRAM

6AV7890-0BE00-1AB0

12" TFT Key
with Windows XP Prof. MUI,
110/230 V AC power supply,
Core i3 2.13 GHz, 2 x PCI,
1 GB RAM, 250 GB HDD
DVD±R/RW burner, PROFIBUS/MPI,
NVRAM

6AV7891-0BE00-1AB0

15" TFT Touch
with Windows XP Prof. MUI,
110/230 V AC power supply,
Core i3 2.13 GHz, 2 x PCI,
1 GB RAM, 250 GB HDD
DVD±R/RW burner, PROFIBUS/MPI,
NVRAM

6AV7892-0BE00-1AB0

15" TFT Key
with Windows XP Prof. MUI,
110/230 V AC power supply,
Core i3 2.13 GHz, 2 x PCI,
1 GB RAM, 250 GB HDD
DVD±R/RW burner, PROFIBUS/MPI,
NVRAM

6AV7893-0BE00-1AB0

19" TFT Touch
with Windows XP Prof. MUI,
110/230 V AC power supply,
Core i3 2.13 GHz, 2 x PCI,
1 GB RAM, 250 GB HDD
DVD±R/RW burner, PROFIBUS/MPI,
NVRAM

6AV7894-0BE00-1AB0

5

5/74

Order No.
Accessories

Siemens ST 80 / ST PC · 2013

Protective film for
Panel PCs 477/577/677/Flat Panel
Set of 10, for protecting the touch
screen against dirt/scratches
• for 12" Touch
• for 15" Touch
• for 19" Touch
Labeling strips for
Panel PC 477/577/677 key devices
For labeling soft keys and function
keys, blank, supplied in sets of 10
Memory expansion
• 1 GB DDR3 1066 SDRAM, DIMM
• 2 GB DDR3 1066 SDRAM, DIMM
• 4 GB DDR3 1066 SDRAM, DIMM
• 1 GB DDR3 1066 SDRAM, DIMM,
ECC
• 2 GB DDR3 1066 SDRAM, DIMM,
ECC
• 4 GB DDR3 1066 SDRAM, DIMM,
ECC
Non-heating apparatus cable for
SIMATIC Box and Panel PC
SIMATIC PC power cable,
230 V AC, angled, 3 m,
for:
• Germany
• United Kingdom
• Switzerland
• USA
• Italy
• China

6AV7671-2BA00-0AA0
6AV7671-4BA00-0AA0
6AV7672-1CE00-0AA0

6AV7672-0DA00-0AA0

6ES7648-2AJ40-0KA0
6ES7648-2AJ50-0KA0
6ES7648-2AJ60-0KA0
6ES7648-2AJ40-1KA0
6ES7648-2AJ50-1KA0
6ES7648-2AJ60-1KA0

6ES7900-1AA00-0XA0
6ES7900-1BA00-0XA0
6ES7900-1CA00-0XA0
6ES7900-1DA00-0XA0
6ES7900-1EA00-0XA0
6ES7900-1FA00-0XA0

Touch pen
Captive pen for operation of the
touch devices, mounting of the
support on the control cabinet

6AV7672-1JB00-0AA0

Expansion components

From page 5/153

Communication components

From page 5/186

© Siemens AG 2013

PC-based Automation
SIMATIC Panel PC
SIMATIC HMI IPC677C

■ Dimensional drawings
All dimensions in mm. For mounting cut-out see technical specifications.
Operating units
IPC 677

G

H

J

K

L

M

N

• 12"

289

271

141

11

53

369

71

• 15"

289

271

138

11

24

367

42

• 19"

378

271

147

11

18

376

36

• 12"

289

271

122

11

42

351

59

• 15"

324

271

141

11

31

370

48

H

G

Touch devices

Key devices

M

Note:
All dimensions without screw clearances.

K

K

L
N

G_ST80_XX_00288

J

Operator control unit and overall device

Front dimensions

Installation cutout

W

H

W+1

H+1

D

• 12"

400

310

368

290

51

• 15"

483

310

450

290

55

• 19"

483

400

450

380

57

• 12"

483

310

450

290

• 15"

483

355

450

3211)

H

Touch devices

Key devices

W

1)

In addition: Two cutouts 25 x 5 mm on the top for keyboard slide-in label
channels.

G_ST80_XX_00289

H+1 (cutout)

W+1 (cutout)

Installation cutout

■ More information
Additional information is available in the Internet under:
http://www.siemens.com/simatic-panel-pc
Note
Do you need a specific modification or option for the products
described here? Under "Customized products", you will find
information about additional sector-specific products that can
be ordered as well as about options for customer-specific
modification and adaptation.

Siemens ST 80 / ST PC · 2013

5/75

5

© Siemens AG 2013

PC-based Automation
SIMATIC PC-based controllers
SIMATIC PC-based controllers

■ Overview
SIMATIC PC-based Control
• Adds PC-based controllers to the SIMATIC S7 controller family
• Especially suitable where a variety of tasks such as data
processing, communication, visualization, technology and
control have to be integrated in one PC.
Versions
• SIMATIC WinAC Software PLC
for tasks requiring a high level of flexibility and integration
capability.
• SIMATIC WinAC ODK
allows PC solutions for technological tasks to be integrated
flexibly and powerfully into the controller.

Siemens has developed a wide range of coordinated hardware
and software components for PC-based Automation.
Focal point: SIMATIC PC-based Control with SIMATIC WinAC,
the open, flexible and reliable controller for your PC-based
automation solution.
All automation tasks can be implemented on one platform on the
PC, such as open-loop control, closed-loop control, HMI and
motion control. PC-based Automation is your first choice
wherever PC applications have to be handled in addition to
classic PLC tasks.

■ More information
Brochures

5

Information material for downloading can be found in the
Internet:
http://www.siemens.com/simatic/printmaterial

5/76

Siemens ST 80 / ST PC · 2013

Properties:
• Runs on standard PCs under Windows XP Professional SP2.
• Code-compatible with SIMATIC S7:
Programmed with SIMATIC industrial software, created
programs can also be used for SIMATIC S7.
• Uses standard interfaces for integration into the office
environment.
• Open interfaces for the integration of solution-specific technological hardware and software.

© Siemens AG 2013

PC-based Automation
SIMATIC PC-based controllers
SIMATIC WinAC RTX

■ Overview
• SIMATIC WinAC RTX:
Optimized for applications that require a high degree of
flexibility and integration capability.
• The software solution for tasks that require hard deterministic
behavior and high performance.
• With real-time expansion for assuring deterministic behavior
for the control section.
New with WinAC RTX 2010:
• Operation under Windows 7
• Web server
• New PROFINET functions:
- Isochronous mode
- Shared Device
- Media redundancy
- IP configuration

■ Technical specifications
6ES7671-0RC08-0YA0

6ES7671-0RC08-0YA0

SIMATIC WinAC RTX 2010
General information
Hardware product version

-

Firmware version

V4.6

Engineering with
• Programming package
Memory
Work memory
• integrated (for program)
• integrated (for data)
Load memory
• integrated RAM, max.

STEP7 as of V5.5 +
HW update / iMap V3.0 SP1

4 Mbyte; Adjustable; depends on
Non Paged Memory Pool
4 Mbyte; Adjustable; depends on
Non Paged Memory Pool
8 Mbyte; Adjustable; depends on
Non Paged Memory Pool

CPU processing times
for bit operations, typ.

0.004 µs; typ.

for fixed point arithmetic, typ.

0.003 µs; typ.

for floating point arithmetic, typ.

0.004 µs; typ.

Reference platform

Pentium IV, 2.4 GHz

CPU-blocks
DB
• Number, max.
• Size, max.
FB
• Number, max.
• Size, max.
FC
• Number, max.

65 535; Limited only
by RAM set for data
64 kbyte
65 536; Limited only
by RAM set for code
64 kbyte

• Size, max.

65 536; Limited only
by RAM set for code
64 kbyte

OB
• Size, max.

64 kbyte

Nesting depth
• per priority class
• additional within an error OB

24
24

SIMATIC WinAC RTX 2010
Counters, timers and
their retentivity
S7 counter
• Number
• Retentivity
- adjustable
- lower limit
- upper limit
- preset
• Counting range
- adjustable
- lower limit
- upper limit

2 048
Yes
0
2 047
8
Yes
0
999

IEC counter
• present
• Type
• Number

Yes
SFB
Unlimited
(limited only by RAM capacity)

S7 times
• Number
• Retentivity
- adjustable
- lower limit
- upper limit
- preset
• Time range
- lower limit
- upper limit

2 048
Yes
0
2 047
0
10 ms
9 990 s

IEC timer
• present
• Type
• Number

Yes
SFB
Unlimited
(limited only by RAM capacity)

Data areas and their retentivity
Retentivity without
UPS and PS Extension Board

128 kbyte with SIMATIC IPC427C
and HMI IPC477C; further
SIMATIC PCs on request

Retentivity with UPS

all data

Flag
• Number, max.
• Retentivity preset
• Number of clock memories

16 kbyte
MB 0 to MB 15
8

Data blocks
• Retentivity adjustable
• Retentivity preset

Yes; via non-retain property on DB
Yes

Siemens ST 80 / ST PC · 2013

5/77

5

© Siemens AG 2013

PC-based Automation
SIMATIC PC-based controllers
SIMATIC WinAC RTX

■ Technical specifications (continued)
6ES7671-0RC08-0YA0

6ES7671-0RC08-0YA0

SIMATIC WinAC RTX 2010
Local data
• adjustable, max.
• preset
• per priority class, max.
Address area
I/O address area
• Inputs
• Outputs
• of which, distributed
- DP interface, inputs
- DP interface, outputs
- PN interface, inputs
- PN interface, outputs

16 kbyte
16 kbyte
16 kbyte
16 kbyte
16 kbyte
16 kbyte

Process image
• Inputs, adjustable
• Outputs, adjustable
• Inputs, default
• Outputs, default

8 kbyte
8 kbyte
512 byte
512 byte

Subprocess images
• Number of subprocess images, max.

15

Digital channels
• Inputs
• Outputs

128 000
128 000

Analog channels
• Inputs
• Outputs

8 000
8 000

Hardware configuration
Submodules
• Number of submodules, max
• of which PROFIBUS, max.

5

64 kbyte
32 kbyte
61 440 byte

• of which Industrial Ethernet, max.
Number of operable FMs and CPs
(recommended)
• FM

• CP, point-to-point
• CP, LAN

4
4; Supported interfaces:
see 1st and 2nd interface
1; Supported interfaces:
see 3rd and 4th interface

FM distributed: FM 350-1 / 350-2,
FM 351, FM 352, FM 353, FM 355 /
355-2
2; CP 340, CP 341 distributed
Over PC CP

Time of day
Clock
• Hardware clock (real-time clock)
• battery-backed and synchronizable

Yes
Yes

Operating hours counter
• Number

8

Clock synchronization
• supported
• to PC-CP, slave
• on Ethernet via NTP

Yes
Yes
Yes

Interfaces
Number of USB interfaces

0

1st interface
Type of interface

CP 5611-A2, CP 5621, integrated
PB interface of the SIMATIC PC

Max. no. of simultaneously operable
CPs

1

Physics

RS 485 / PROFIBUS

Isolated

Yes

Power supply to interface
(15 to 30 V DC), max.

does not exist

Number of connection resources

8

5/78

Siemens ST 80 / ST PC · 2013

SIMATIC WinAC RTX 2010
Functionality
• MPI
• DP master
• DP slave
DP master
• Number of connections, max.
• Transmission rate, max.
• Number of DP slaves, max.
• Services
- PG/OP communication
- Global data communication
- S7 basic communication
- S7 communication
- S7 communication, as client
- S7 communication, as server
- Equidistance mode support
- Isochronous mode
- SYNC/FREEZE
- Activation/deactivation of DP
slaves
- Direct data exchange
(slave-to-slave communication)
- DPV1
• Address area
- Inputs, max.
- Outputs, max.
• User data per DP slave
- Inputs, max.
- Outputs, max.
2nd interface
Type of interface

No
Yes
No
8
12 Mbit/s
64
Yes
No
No
Yes
Yes
Yes
Yes; Only in conjunction
with isochronous mode
Yes
Yes
Yes
Yes
Yes
16 kbyte
16 kbyte
244 byte
244 byte
CP 5613, CP 5613-A2, CP 5603

Max. no. of simultaneously operable
CPs

4

Physics

RS 485 / PROFIBUS

Isolated

Yes

Functionality
• MPI
• DP master
• DP slave

No
Yes
No

DP master
• Number of connections, max.
• Transmission rate, max.
• Number of DP slaves, max.
• Services
- PG/OP communication
- Global data communication
- S7 basic communication
- S7 communication
- S7 communication, as client
- S7 communication, as server
- Equidistance mode support
- Isochronous mode
- SYNC/FREEZE
- Activation/deactivation of DP
slaves
- Direct data exchange
(slave-to-slave communication)
- DPV1
• Address area
- Inputs, max.
- Outputs, max.
• User data per DP slave
- Inputs, max.
- Outputs, max.

50
12 Mbit/s
125
Yes
No
No
Yes
Yes
Yes
Yes; Only in conjunction
with isochronous mode
Yes
Yes
Yes
Yes
Yes
16 kbyte
16 kbyte
244 byte
244 byte

© Siemens AG 2013

PC-based Automation
SIMATIC PC-based controllers
SIMATIC WinAC RTX

■ Technical specifications (continued)
6ES7671-0RC08-0YA0

6ES7671-0RC08-0YA0

SIMATIC WinAC RTX 2010
3rd interface
Type of interface

PROFINET

SIMATIC WinAC RTX 2010
4th interface
Type of interface

PROFINET

1; Intel Pro/1000 (Intel 82571EB,
82573L, 82574L, 82541PI;
non-shared IRQ required);
integrated IE interface
SIMATIC PC 4x7B, 6x7B, 8x7B,
IPC4x7C, IPC6x7C, IPC8x7C

Max. no. of simultaneously operable
CPs

1; CP 1616 (HW release 8 or above),
CP 1604 (HW release 7 or higher),
integrated PN interface of
SIMATIC PC and S7-mEC

Physics

Ethernet

Ethernet

Isolated

Yes

Yes

Integrated switch

Yes

No

Number of ports

3

Number of ports

1

Automatic detection of transmission
speed

Yes; 10/100 Mbit/s

Automatic detection of transmission
speed

Yes; 10/100 Mbit/s

Autonegotiation

Yes

Yes

Autocrossing

Yes

Autocrossing

Yes

Change of IP address at runtime,
supported

Yes

Media redundancy
• supported

No

Number of connection resources

32

Max. no. of simultaneously operable
CPs

Physics
Isolated
Integrated switch

Autonegotiation

Functionality
• PROFINET IO Controller
• PROFINET IO Device
• PROFINET CBA
PROFINET IO Controller
• Transmission rate, min.
• Transmission rate, max.
• Max. number of connectable
IO devices for RT
- of which in line, max.
• IRT, supported
• Prioritized startup supported
- Number of IO Devices, max.
• Activation/deactivation of IO Devices
- Maximum number of IO devices
that can be activated/deactivated
at the same time.
• IO Devices changing during operation (partner ports), supported
• Device replacement without swap
medium
• Send cycles
• Updating time

• Services
- PG/OP communication
- S7 communication
- Isochronous mode
- Open IE communication
• Address area
- Inputs, max.
- Outputs, max.
- User data per address area, max.
- User data consistency, max.
Open IE communication
• Open IE communication, supported
• Number of connections, max.
• Local port numbers used at the system end
• Keep-alive function, supported

Yes
No
Yes

Media redundancy
• supported
• Switchover time on line break,
typically
• Number of stations in the ring, max.

100 Mbit/s
100 Mbit/s
128

Functionality
• PROFINET IO Controller
• PROFINET IO Device
• PROFINET CBA

128
No
Yes
32
Yes
8

Yes
Yes
1 ms
1 - 512 ms (minimum value
depends on communication share
set for PROFINET I/O, on the number of I/O devices, and on the
volume of configured user data)
Yes
Yes
No
Yes
16 kbyte
16 kbyte
2 kbyte
256 byte
Yes
32
0, 20, 21, 23, 25, 80, 102, 135, 161,
8080, 34962, 34963, 34964, 65532,
65533, 65534, 65535
Yes

Yes
200 ms
50
Yes
No
Yes

PROFINET IO Controller
• Transmission rate, max.
• Max. number of connectable
IO Devices for RT
- of which in line, max.
• Number of IO devices with IRT
and the option "high flexibility"
- of which in line, max.
• Number of IO Devices with IRT and
the option "high performance", max.
- of which in line, max.
• IRT, supported
• Prioritized startup supported
- Number of IO Devices, max.
• Activation/deactivation of IO Devices
- Maximum number of IO devices
that can be activated/deactivated
at the same time.
• IO Devices changing during
operation (partner ports), supported
• Device replacement without swap
medium
• Send cycles
• Updating time
• Services
- PG/OP communication
- S7 communication
- Isochronous mode
- Open IE communication
• Address area
- Inputs, max.
- Outputs, max.
- User data per address area, max.
- User data consistency, max.

100 Mbit/s
256

5

256
64
32
64
32
Yes
Yes
32
Yes
8

Yes
Yes
250 µs, 500 µs, 1 ms
0.25...512 depending
on the send cycle
Yes
Yes
Yes
Yes
16 kbyte
16 kbyte
2 kbyte
256 byte

Siemens ST 80 / ST PC · 2013

5/79

© Siemens AG 2013

PC-based Automation
SIMATIC PC-based controllers
SIMATIC WinAC RTX

■ Technical specifications (continued)
6ES7671-0RC08-0YA0

6ES7671-0RC08-0YA0

SIMATIC WinAC RTX 2010
Open IE communication
• Open IE communication, supported
• Number of connections, max.
• Local port numbers used
at the system end
Isochronous mode
Isochronous operation (application
synchronized up to terminal)

Yes

Number of DP masters
with isochronous mode

2

User data per isochronous slave, max.

128 byte

equidistance

Yes

shortest clock pulse

2.2 ms; 2.2 ms without partial p
rocess image; 2.2 ms with partial
process image

Communication functions
PG/OP communication
Data record routing

Yes
Yes; Only with CP 5611 or
integrated PROFIBUS interface of
the SIMATIC PC

Global data communication
• supported

No

S7 basic communication
• supported

No

S7 communication
• supported
• as server
• as client
• User data per job, max.

5

Yes
32
0, 20, 21, 25, 80, 102, 135, 161,
34962, 34963, 34964, 65532,
65533, 65534, 65535

Open IE communication
• TCP/IP
- Number of connections, max.
- Data length for connection type
01H, max.
- Data length for connection type
11H, max.
- Data length, max.
• ISO-on-TCP (RFC1006)
- Number of connections, max.
- Data length, max.
• UDP
- Number of connections, max.
- Data length, max.
Web server
• supported
• Number of HTTP clients
• User-defined websites

Yes
Yes
Yes
64 kbyte;
When using BSEND/USEND
Yes
32
Not supported
65 534 byte
65 534 byte
Yes
32
65 534 byte
Yes
32
1 472 byte
Yes
2
No

SIMATIC WinAC RTX 2010
PROFINET CBA
(at set setpoint communication load)
• Setpoint for the CPU communication
load
• Number of remote interconnection
partners
• Number of functions, master/slave
• Total of all Master/Slave connections
• Data length of all incoming
connections master/slave, max.
• Data length of all outgoing
connections master/slave, max.
• Number of device-internal
and PROFIBUS interconnections
• Data length of device-internal und
PROFIBUS interconnections, max.
• Data length per connection, max.
• Remote interconnections
with acyclic transmission
- Sampling frequency:
Sampling time, min.
- Number of incoming
interconnections
- Number of outgoing
interconnections
- Data length of all incoming
interconnections, max.
- Data length of all outgoing
interconnections, max.
- Data length per connection, max.
• Remote interconnections with cyclic
transmission
- Transmission frequency:
Transmission interval, min.
- Number of incoming
interconnections
- Number of outgoing
interconnections
- Data length of all incoming
interconnections, max.
- Data length of all outgoing
interconnections, max.
- Data length per connection, max.
• HMI variables via PROFINET
(acyclic)
- Number of stations that can log on
for HMI variables (PN OPC/iMap)
- HMI variable updating
- Number of HMI variables
- Data length of all HMI variables,
max.
• PROFIBUS proxy functionality
- supported
- Number of linked
PROFIBUS devices
- Data length per connection, max.
Number of connections
• overall

5/80

Siemens ST 80 / ST PC · 2013

20 %
64
30
1 000
6 800 byte
6 800 byte
500
4 000 byte
1 400 byte

500 ms
100
100
2 000 byte
2 000 byte
1 400 byte

10 ms
200
200
4 800 byte
4 800 byte
250 byte

3
500 ms
200
2 000 byte

Yes
16
240 byte; Slave-dependent
96

© Siemens AG 2013

PC-based Automation
SIMATIC PC-based controllers
SIMATIC WinAC RTX

■ Technical specifications (continued)
6ES7671-0RC08-0YA0

6ES7671-0RC08-0YA0

SIMATIC WinAC RTX 2010
S7 message functions
Number of login stations for message
functions, max.

62

SCAN procedure

No

Process diagnostic messages

Yes; ALARM_S, ALARM_SQ,
ALARM_D, ALARM_DQ

simultaneously active Alarm-S blocks,
max.

20; of a total of 20 for all SFCs

Alarm 8-blocks
• Number of instances for alarm 8
and S7 communication blocks, max.

Yes
4 000

Process control messages

No

Test commissioning functions
Status block

Yes

Single step

Yes

Number of breakpoints

20

Status/control
• Status/control variable

Yes

Forcing
• Forcing

No

Diagnostic buffer
• present
• Number of entries, max.
- adjustable
- preset

Yes
3 200
Yes
120

Hardware requirements
Hardware required

PC with color monitor, keyboard,
mouse or pointing device for
Windows

Required memory on hard disk, min.

100 Mbyte

Main memory, min.

1 Gbyte; WES7: 2 GB

Processor

Intel Celeron M,
900 MHz or compatible
Yes; Dual Pentium, CoreDuo,
Core2Duo or compatible
Yes

• Multi-processor system
• Hyper-threading

SIMATIC WinAC RTX 2010
Operating systems
Windows NT 4.0

No

Windows 2000

No

Windows XP

Yes; Professional, SP2 and SP3

Windows XP embedded

Yes; With the delivery image of the
SIMATIC PC
ACPI uniprocessor PC,
ACPI multiprocessor PC,
MPS multiprocessor PC

• Supported HAL types
under Windows XP
Windows Vista

No

Windows 7

Yes; Professional, Enterprise,
Ultimate (only 32 bits)

Windows embedded Standard 7

Yes

Configuration
programming
• Nesting levels
• Programming language
- LAD
- FBD
- STL
- SCL
- CFC
- GRAPH
- HiGraph®
• Software libraries
- Easy Motion Control

8
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

Know-how protection
• User program protection/password
protection
Open Development interfaces
• CCX (Custom Code Extension)
• CMI (Controller Management
Interface)
• SMX (Shared Memory Extension)
- Inputs
- Outputs
Weight
Weight, approx.

Yes

Yes; WinAC ODK V4.2 or higher
Yes; WinAC ODK V4.2 or higher
Yes; WinAC ODK V4.2 or higher
4 kbyte
4 kbyte
100 g; With packaging

Siemens ST 80 / ST PC · 2013

5/81

5

© Siemens AG 2013

PC-based Automation
SIMATIC PC-based controllers
SIMATIC WinAC RTX

■ Ordering data
SIMATIC WinAC RTX 2010

Order No.
6ES7671-0RC08-0YA0

Software PLC for PC-based
automation tasks with stringent
deterministic requirements;
PROFIBUS and PROFINET;
CD-ROM with electronic
documentation d, e, f;
single license, executable under
Windows XP SP2 and SP3
as well as Windows 7 (32 bit)
SIMATIC WinAC RTX 2010
Upgrade

6ES7671-0RC08-0YE0

For upgrading from basic/RTX V3.x,
V4.0, V4.1 2005, 2008 and 2009;
single license, executable under
Windows XP SP2 and SP3 and
Windows 7 (32 bit)
CP 5611 A2
communications processor

6GK1561-1AA01

CP 5603 Microbox Package

6GK1562-1AA00

6GK1560-3AU00

Comprising CP 5603 module and
Microbox expansion rack
CP 5613 A2
communications processor

5

6GK1561-3AA01

PCI card (32 bit; 3.3 V/5 V) for
connection to PROFIBUS incl.
DP-Base software with NCM PC;
DP-RAM interface for DP master,
incl. PG and FDL protocol; single
license for 1 installation, runtime
software, software and electronic
manual on CD-ROM, Class A, for
32 bit Windows 2000 Professional/
Server, Windows XP Professional,
German/English

5/82

Siemens ST 80 / ST PC · 2013

6GK1161-6AA02

PCI Card (32 bit; 3.3/5 V universal
key) with ASIC ERTEC 400 for
connecting PCs to PROFINET IO
with 4-port real-time switch (RJ45);
incl. IO-Base software for
PROFINET IO controller (RT operation) and NCM PC; single license for
one installation, runtime software,
software and electronic manual on
CD-ROM, Class A, for 32 bit
Windows XP Professional;
German/English
CP 1604 Microbox Package

6GK1562-1AM00

6GK1562-3AA00

PCI Express x1 card (32 bit) for
connection to PROFIBUS incl.
DP-Base software with NCM PC;
DP-RAM interface for DP master or
DP slave, incl. PG and FDL protocols; single license for 1 installation,
runtime software, software and electronic manual on CD-ROM, Class A,
for operating system support see
SIMATIC NET software;
German/English
CP 1616
communications processor

PCI card (32 bit) for connection
of a programming device or PC
to PROFIBUS
CP 5621
communications processor
• PCI Express x1 card (32 bit)
for connection of a programming
device or PC to PROFIBUS
• PCI Express x1 card (32 bit)
CP 5621 and MPI cable, 5 m

Order No.
CP 5623
communications processor

Package for implementing
the CP 1604 in the
SIMATIC Microbox PC;
comprising the CP 1604, connection
board, power supply and expansion
rack for Microbox PC; for use with
Development Kit DK-16xx PN IO;
NCM PC

6GK1160-4AU00

© Siemens AG 2013

PC-based Automation
SIMATIC PC-based controllers
SIMATIC WinAC RTX

■ More information
Add-ons for SIMATIC WinAC

Application

Function

PC-based Competence Center Cologne

WinAC serial driver

Our add-ons supplement the WinAC RTX soft PLC by useful
functions which have arisen in the context of projects. You can
thus fully utilize the advantages of PC-based automation.

Communication over
serial interfaces

WinAC PC IO driver

Access to central I/O expansion
PC IO including interrupt handling

WinAC SQL

Access to SQL databases

WinAC TCP/IP driver

Data exchange between WinAC and
other communication partners over
Windows interface using TCP/IP,
UDP, or ISO-on-TCP

WinAC OPC Client

Access to various OPC servers

WinAC Shutdown

Controlled shutdown of WinAC and
PC system

WinAC File-I/O

Reading and writing of DBs as file
on the PC system

WinAC Command

Calling of batch commands from
WinAC

WinAC Access-DB

High-performance access to DBs,
bit memories or I/O image

WinAC SMX Cover

Provision of SMX functions,
e.g. for Delphi or VB

WinAC CMI Wrapper

Simple program-based operation
of WinAC

The applications are available in the form of function blocks and
are easy to use without special programming knowledge.
Detailed information and prices can be obtained from your
Siemens contact or from:
Contact:
Siemens AG
Competence Center Cologne
E-mail: CCCologne@siemens.com

Brochures
Information material for downloading can be found in the
Internet:
http://www.siemens.com/simatic/printmaterial

5

Siemens ST 80 / ST PC · 2013

5/83

© Siemens AG 2013

PC-based Automation
SIMATIC PC-based controllers
SIMATIC WinAC RTX F

■ Overview

■ Technical specifications
6ES7671-1RC08-0YA0
SIMATIC WinAC RTX F 2010
General information
Hardware product version

-

Firmware version

V4.6

Engineering with
• Programming package

Memory
Work memory
• integrated (for program)
• integrated (for data)
Load memory
• integrated RAM, max.

• SIMATIC WinAC RTX F:
Optimized for applications that demand a high degree of
flexibility and integration capability and that must also satisfy
safety requirements up to SIL 3 (IEC 61508).
• The software solution for tasks that require hard deterministic
behavior and high performance.
• With real-time expansion for assuring deterministic behavior
for the control section.
• Distributed I/O can be connected over PROFIBUS and/or
PROFINET, also safety-related over PROFIsafe.

for fixed point arithmetic, typ.

0.003 µs; typ.

for floating point arithmetic, typ.

0.004 µs; typ.

Reference platform

Pentium IV, 2.4 GHz

CPU-blocks
DB
• Number, max.

• Size, max.
FC
• Number, max.

65 535; Limited only
by RAM set for data
64 kbyte
65 536; Limited only
by RAM set for code
64 kbyte

• Size, max.

65 536; Limited only
by RAM set for code
64 kbyte

OB
• Size, max.

64 kbyte

Nesting depth
• per priority class
• additional within an error OB

24
24

Counters, timers and
their retentivity
S7 counter
• Number
• Retentivity
- adjustable
- lower limit
- upper limit
- preset
• Counting range
- adjustable
- lower limit
- upper limit
IEC counter
• present
• Type
• Number

Siemens ST 80 / ST PC · 2013

Adjustable; depends on
Non Paged Memory Pool
0.004 µs; typ.

FB
• Number, max.

5/84

4 Mbyte; Adjustable; depends on
Non Paged Memory Pool
4 Mbyte; Adjustable; depends on
Non Paged Memory Pool

CPU processing times
for bit operations, typ.

• Size, max.

5

STEP 7 V5.5 or higher + hardware
update / iMap V3.0 SP1 / option
package S7 Distributed Safety V5.4
+ SP5 / S7 F Configuration Pack
V5.5 + SP6 + HF1

2 048
Yes
0
2 047
8
Yes
0
999
Yes
SFB
Unlimited
(limited only by RAM capacity)

© Siemens AG 2013

PC-based Automation
SIMATIC PC-based controllers
SIMATIC WinAC RTX F

■ Technical specifications (continued)
6ES7671-1RC08-0YA0

6ES7671-1RC08-0YA0

SIMATIC WinAC RTX F 2010
S7 times
• Number
• Retentivity
- adjustable
- lower limit
- upper limit
- preset
• Time range
- lower limit
- upper limit

2 048
Yes
0
2 047
0
10 ms
9 990 s

SIMATIC WinAC RTX F 2010
Hardware configuration
Submodules
• Number of submodules, max
• of which PROFIBUS, max.
• of which Industrial Ethernet, max.
Number of operable FMs and CPs
(recommended)
• FM

4
4; Supported interfaces:
see 1st and 2nd interface
1; Supported interfaces:
see 3rd and 4th interface

• CP, point-to-point
• CP, LAN

4; FM distributed: FM 350-1,
FM 350-2, FM 351, FM 352 /
FM 352-5, FM 353, FM 354,
FM 355, FM 355-2
2; CP 340, CP 341 distributed
Over PC CP

Time of day
Clock
• Hardware clock (real-time clock)
• battery-backed and synchronizable

Yes
Yes

all data

Operating hours counter
• Number

8

Flag
• Number, max.
• Retentivity preset
• Number of clock memories

16 kbyte
MB 0 to MB 15
8

Clock synchronization
• supported
• to PC-CP, slave
• on Ethernet via NTP

Yes
Yes
Yes

Data blocks
• Retentivity adjustable
• Retentivity preset

Yes; via non-retain property on DB
Yes

Local data
• adjustable, max.
• preset
• per priority class, max.

64 kbyte
32 kbyte
61 440 byte

IEC timer
• present
• Type
• Number
Data areas and their retentivity
Retentivity without
UPS and PS Extension Board
Retentivity with UPS

Address area
I/O address area
• Inputs
• Outputs
• of which, distributed
- DP interface, inputs
- DP interface, outputs
- PN interface, inputs
- PN interface, outputs

Yes
SFB
Unlimited
(limited only by RAM capacity)
128 kbyte with SIMATIC IPC427C
and HMI IPC477C;
further SIMATIC PCs on request

16 kbyte
16 kbyte
16 kbyte
16 kbyte
16 kbyte
16 kbyte

Process image
• Inputs, adjustable
• Outputs, adjustable
• Inputs, default
• Outputs, default

8 kbyte
8 kbyte
512 byte
512 byte

Subprocess images
• Number of subprocess images, max.

15

Digital channels
• Inputs
• Outputs

128 000
128 000

Analog channels
• Inputs
• Outputs

8 000
8 000

1st interface
Type of interface

CP 5611-A2, CP 5621, integrated
PB interface of the SIMATIC PC

Max. no. of simultaneously
operable CPs

1

Physics

RS 485 / PROFIBUS

Isolated

Yes

Power supply to interface
(15 to 30 V DC), max.

does not exist

Number of connection resources

8

Functionality
• MPI
• DP master
• DP slave

No
Yes
No

DP master
• Number of connections, max.
• Transmission rate, max.
• Number of DP slaves, max.
• Services
- PG/OP communication
- Global data communication
- S7 basic communication
- S7 communication
- S7 communication, as client
- S7 communication, as server
- Equidistance mode support
- Isochronous mode
- SYNC/FREEZE
- Activation/deactivation of DP
slaves
- Direct data exchange (slave-toslave communication)
- DPV1
• Address area
- Inputs, max.
- Outputs, max.
• User data per DP slave
- Inputs, max.
- Outputs, max.

5

8
12 Mbit/s
64
Yes
No
No
Yes
Yes
Yes
Yes; Only in conjunction
with isochronous mode
Yes
Yes
Yes
Yes
Yes
16 kbyte
16 kbyte
244 byte
244 byte

Siemens ST 80 / ST PC · 2013

5/85

© Siemens AG 2013

PC-based Automation
SIMATIC PC-based controllers
SIMATIC WinAC RTX F

■ Technical specifications (continued)
6ES7671-1RC08-0YA0

6ES7671-1RC08-0YA0

SIMATIC WinAC RTX F 2010
2nd interface
Type of interface
Max. no. of simultaneously operable
CPs

4

Physics

RS 485 / PROFIBUS

Isolated

Yes

Functionality
• MPI
• DP master
• DP slave

No
Yes
No

DP master
• Number of connections, max.
• Transmission rate, max.
• Number of DP slaves, max.
• Services
- PG/OP communication
- Global data communication
- S7 basic communication
- S7 communication
- S7 communication, as client
- S7 communication, as server
- Equidistance mode support

5

CP 5613, CP 5613-A2, CP 5603,
CP 5623

- Isochronous mode
- SYNC/FREEZE
- Activation/deactivation of DP
slaves
- Direct data exchange
(slave-to-slave communication)
- DPV1
• Address area
- Inputs, max.
- Outputs, max.
• User data per DP slave
- Inputs, max.
- Outputs, max.
3rd interface
Type of interface
Max. no. of simultaneously
operable CPs

50
12 Mbit/s
125
Yes
No
No
Yes
Yes
Yes
Yes; Only in conjunction
with isochronous mode
Yes
Yes
Yes
Yes
Yes
16 kbyte
16 kbyte
244 byte
244 byte

SIMATIC WinAC RTX F 2010
PROFINET IO Controller
• Transmission rate, min.
• Transmission rate, max.
• Number of connectable IO devices,
max.
• Max. number of connectable
IO devices for RT
- of which in line, max.
• IRT, supported
• Prioritized startup supported
- Number of IO Devices, max.
• Activation/deactivation of
IO Devices
- Maximum number of IO devices
that can be activated/deactivated
at the same time.
• IO Devices changing during operation (partner ports), supported
• Device replacement without swap
medium
• Send cycles
• Updating time

• Services
- PG/OP communication
- S7 communication
- Isochronous mode
- Open IE communication
• Address area
- Inputs, max.
- Outputs, max.
- User data per address area, max.
- User data consistency, max.
Open IE communication
• Open IE communication, supported
• Number of connections, max.
• Local port numbers used at the
system end

128
128
No
Yes
32
Yes
8

Yes
Yes
1 ms
1 - 512 ms (minimum value depends
on communication share set for
PROFINET I/O, on the number of
I/O devices, and on the volume of
configured user data)
Yes
Yes
No
Yes
16 kbyte
16 kbyte
2 kbyte
256 byte

• Keep-alive function, supported

Yes
32
0, 20, 21, 23, 25, 80, 102, 135, 161,
8080, 34962, 34963, 34964, 65532,
65533, 65534, 65535
Yes

4th interface
Type of interface

PROFINET

PROFINET
1; Intel Pro/1000 (Intel 82571EB,
82573L, 82574L, 82541PI;
non-shared IRQ required);
integrated IE interface
SIMATIC PC 4x7B, 6x7B, 8x7B,
IPC4x7C, IPC6x7C, IPC8x7C

100 Mbit/s
100 Mbit/s
128

Max. no. of simultaneously
operable CPs

1; CP 1616 (HW release 8 or above),
CP 1604 (HW release 7 or higher),
integrated PN interface of
SIMATIC PC and S7-mEC

Physics

Ethernet

Isolated

Yes

Physics

Ethernet

Integrated switch

No

Isolated

Yes

Number of ports

1

Integrated switch

Yes

Automatic detection of transmission
speed

Yes; 10/100 Mbit/s

Number of ports

3

Autonegotiation

Yes

Automatic detection of transmission
speed

Yes; 10/100 Mbit/s

Autocrossing

Yes

Autonegotiation

Yes

Autocrossing

Yes

Change of IP address at runtime,
supported

Yes

Number of connection resources

32

Media redundancy
• supported

No

Functionality
• PROFINET IO Controller
• PROFINET IO Device
• PROFINET CBA

Yes
No
Yes

5/86

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
SIMATIC PC-based controllers
SIMATIC WinAC RTX F

■ Technical specifications (continued)
6ES7671-1RC08-0YA0

6ES7671-1RC08-0YA0

SIMATIC WinAC RTX F 2010
Media redundancy
• supported
• Switchover time on line break,
typically
• Number of stations in the ring, max.
Functionality
• PROFINET IO Controller
• PROFINET IO Device
• PROFINET CBA
PROFINET IO Controller
• Transmission rate, max.
• Max. number of connectable
IO Devices for RT
- of which in line, max.
• Number of IO devices with IRT and
the option "high flexibility"
- of which in line, max.
• Number of IO Devices with IRT and
the option "high performance", max.
- of which in line, max.
• IRT, supported
• Prioritized startup supported
- Number of IO Devices, max.
• Activation/deactivation of IO Devices
- Maximum number of IO devices
that can be activated/deactivated
at the same time.
• IO Devices changing during operation (partner ports), supported
• Device replacement without
swap medium
• Send cycles
• Updating time
• Services
- PG/OP communication
- S7 communication
- Isochronous mode
- Open IE communication
• Address area
- Inputs, max.
- Outputs, max.
- User data per address area, max.
- User data consistency, max.
Open IE communication
• Open IE communication, supported
• Number of connections, max.
• Local port numbers used at the
system end
Isochronous mode
Isochronous operation (application
synchronized up to terminal)

Yes
200 ms

SIMATIC WinAC RTX F 2010
Communication functions
PG/OP communication

Yes
Yes; Only with CP 5611 or
integrated PROFIBUS interface
of the SIMATIC PC

Data record routing

50
Yes
No
Yes
100 Mbit/s
256
256
64
32
64
64
Yes
Yes
32
Yes
8

Yes
Yes

Global data communication
• supported

No

S7 basic communication
• supported

No

S7 communication
• supported
• as server
• as client
• User data per job, max.

Yes
Yes
Yes
64 kbyte; Depends on which block
is used: BSEND/USEND or PUT/GET

Open IE communication
• TCP/IP
- Number of connections, max.
- Data length for connection type
01H, max.
- Data length for connection type
11H, max.
- Data length, max.
• ISO-on-TCP (RFC1006)
- Number of connections, max.
- Data length, max.
• UDP
- Number of connections, max.
- Data length, max.

250 µs, 500 µs, 1 ms
0.25...512 depending on the send
cycle

Web server
• supported
• Number of HTTP clients
• User-defined websites

Yes
Yes
Yes
Yes

PROFINET CBA (at set setpoint
communication load)
• Setpoint for the CPU communication
load
• Number of remote interconnection
partners
• Number of functions, master/slave
• Total of all Master/Slave connections
• Data length of all incoming
connections master/slave, max.
• Data length of all outgoing
connections master/slave, max.
• Number of device-internal
and PROFIBUS interconnections
• Data length of device-internal und
PROFIBUS interconnections, max.
• Data length per connection, max.
• Remote interconnections with
acyclic transmission
- Sampling frequency:
Sampling time, min.
- Number of incoming
interconnections
- Number of outgoing
interconnections
- Data length of all incoming
interconnections, max.
- Data length of all outgoing
interconnections, max.
- Data length per connection, max.

16 kbyte
16 kbyte
2 kbyte
256 byte
Yes
32
0, 20, 21, 25, 80, 102, 135, 161,
34962, 34963, 34964, 65532,
65533, 65534, 65535
Yes

Number of DP masters
with isochronous mode

2

User data per isochronous slave, max.

128 byte

equidistance

Yes

shortest clock pulse

2.2 ms; 2.2 ms without partial
process image; 2.2 ms with partial
process image

Yes
32
Not supported
65 534 byte
65 534 byte
Yes
32
65 534 byte
Yes
32
1 472 byte
Yes
2
No

5

20 %
64
30
1 000
6 800 byte
6 800 byte
500
4 000 byte
1 400 byte

500 ms
100
100
2 000 byte
2 000 byte
1 400 byte

Siemens ST 80 / ST PC · 2013

5/87

© Siemens AG 2013

PC-based Automation
SIMATIC PC-based controllers
SIMATIC WinAC RTX F

■ Technical specifications (continued)
6ES7671-1RC08-0YA0

6ES7671-1RC08-0YA0

SIMATIC WinAC RTX F 2010
• Remote interconnections
with cyclic transmission
- Transmission frequency:
Transmission interval, min.
- Number of incoming
interconnections
- Number of outgoing
interconnections
- Data length of all incoming
interconnections, max.
- Data length of all outgoing
interconnections, max.
- Data length per connection, max.
• HMI variables via PROFINET
(acyclic)
- Number of stations that can log on
for HMI variables (PN OPC/iMap)
- HMI variable updating
- Number of HMI variables
- Data length of all HMI variables,
max.
• PROFIBUS proxy functionality
- supported
- Number of linked
PROFIBUS devices
- Data length per connection, max.
Number of connections
• overall

5

10 ms

PC with color monitor, keyboard,
mouse or pointing device for
Windows

200

Required memory on hard disk, min.

100 Mbyte

200

Main memory, min.

1 Gbyte

Processor

• Multi-processor system
• Hyper-threading

Intel Celeron M 900 MHz or
compatible (older PC systems with
Programmable Interrupt Controllers
(PIC) are not suitable for
WinAC RTX F 2010.)
No
Yes

Operating systems
Windows NT 4.0

No

500 ms
200
2 000 byte

Windows 2000

No

Windows XP

Yes; Professional, SP2 and SP3

Windows XP embedded

Yes
16

• Supported HAL types
under Windows XP

Yes; With the delivery image of the
SIMATIC PC
ACPI uniprocessor PC,
ACPI multiprocessor PC,
MPS multiprocessor PC

240 byte; Slave-dependent

Windows Vista

No

Windows 7

Yes; Professional, Enterprise,
Ultimate (only 32 bits)

Windows embedded Standard 7

No

4 800 byte
4 800 byte
250 byte

3

96

S7 message functions
Number of login stations for message
functions, max.

62

SCAN procedure

No

Process diagnostic messages

Yes; ALARM_S, ALARM_SQ,
ALARM_D, ALARM_DQ

simultaneously active Alarm-S blocks,
max.

20; of a total of 20 for all SFCs

Alarm 8-blocks
• Number of instances for alarm 8 and
S7 communication blocks, max.

Yes
4 000

Process control messages

No

Test commissioning functions
Status block

Yes

Single step

Yes

Number of breakpoints

20

Status/control
• Status/control variable

Yes

Forcing
• Forcing

No

Diagnostic buffer
• present
• Number of entries, max.
- adjustable
- preset

Yes
3 200
Yes
120

5/88

SIMATIC WinAC RTX F 2010
Hardware requirements
Hardware required

Siemens ST 80 / ST PC · 2013

Configuration
programming
• Nesting levels
• Programming language
- LAD
- FBD
- STL
- SCL
- CFC
- GRAPH
- HiGraph®
• Software libraries
- Easy Motion Control
Know-how protection
• User program protection/password
protection
• Block encryption
Open Development interfaces
• CCX (Custom Code Extension)
• CMI (Controller Management
Interface)
• SMX (Shared Memory Extension)
- Inputs
- Outputs
Weight
Weight, approx.

8
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
Yes; WinAC ODK V4.2 or higher
Yes; WinAC ODK V4.2 or higher
Yes; WinAC ODK V4.2 or higher
4 kbyte
4 kbyte
100 g; With packaging

© Siemens AG 2013

PC-based Automation
SIMATIC PC-based controllers
SIMATIC WinAC RTX F

■ Ordering data

Order No.

■ More information

SIMATIC WinAC RTX F 2010

6ES7671-1RC08-0YA0

Add-ons for SIMATIC WinAC

SIMATIC WinAC RTX F 2010
upgrade

6ES7671-1RC08-0YE0

PC-based Competence Center Cologne

CP 5611 A2
communications processor

6GK1561-1AA01

Our add-ons supplement the WinAC RTX soft PLC by useful
functions which have arisen in the context of projects. In this
way, you can fully utilize the advantages of PC based
Automation.

PCI card (32 bit) for connection
of a programming device or PC
to PROFIBUS

The applications are available in the form of function blocks and
are easy to use without special programming knowledge.

CP 5621
communications processor
PCI Express x1 card (32 bit) for
connection of a programming
device or PC to PROFIBUS

6GK1562-1AA00

PCI Express x1 card (32 bit)
CP 5621 and MPI cable, 5 m

6GK1562-1AM00

CP 5603 Microbox Package

6GK1560-3AU00

Contact:

Comprising CP 5603 module and
Microbox expansion rack
CP 5613 A2
communications processor

6GK1561-3AA01

PCI card (32 bit; 3.3 V/5 V) for
connection to PROFIBUS incl.
DP-Base software with NCM PC;
DP-RAM interface for DP master,
incl. PG and FDL protocol; single
license for 1 installation, runtime
software, software and electronic
manual on CD-ROM, Class A, for
32 bit Windows 2000 Professional/
Server, Windows XP Professional,
German/English
CP 5623
communications processor

6GK1161-6AA02

PCI Card (32 bit; 3.3/5 V universal
key) with ASIC ERTEC 400 for
connecting PCs to PROFINET IO
with 4-port real-time switch (RJ45);
incl. IO-Base software for
PROFINET IO controller (RT operation) and NCM PC; single license for
one installation, runtime software,
software and electronic manual on
CD-ROM, Class A, for 32 bit
Windows XP Professional;
German/English
CP 1604 Microbox Package

Siemens AG
Competence Center Cologne
E-mail: CCCologne@siemens.com
Application

Function

WinAC serial driver

Communication over
serial interfaces

WinAC PC IO driver

Access to central I/O expansion
PC IO including interrupt handling

WinAC SQL

Access to SQL databases

WinAC TCP/IP driver

Data exchange between WinAC and
other communication partners over
Windows interface using TCP/IP,
UDP, or ISO-on-TCP

WinAC OPC Client

Access to various OPC servers

WinAC Shutdown

Controlled shutdown of WinAC and
the PC system

WinAC File I/O

Reading and writing of DBs as a
file on the PC system

WinAC Command

Calling batch commands from
WinAC

WinAC Access DB

High-performance accesses to DBs,
bit memories or I/O image

WinAC SMX Cover

Provides SMX functions,
e.g. for Delphi or VB

WinAC CMI Wrapper

Easy program-controlled operation
of WinAC

6GK1562-3AA00

PCI Express x1 card (32 bit) for
connection to PROFIBUS incl.
DP-Base software with NCM PC;
DP-RAM interface for DP master or
DP slave, incl. PG and FDL protocols; single license for 1 installation,
runtime software, software and electronic manual on CD-ROM, Class A,
for operating system support see
SIMATIC NET software;
German/English
CP 1616
communications processor

Detailed information and prices can be obtained from your
Siemens contact or from:

Brochures
Information material is available for downloading in the Internet
at:
http://www.siemens.com/simatic/printmaterial

6GK1160-4AU00

Package for implementing the
CP 1604 in the SIMATIC Microbox
PC; comprising the CP 1604,
connection board, power supply
and expansion rack for
Microbox PC; for use with Development Kit DK-16xx PN IO; NCM PC

Siemens ST 80 / ST PC · 2013

5/89

5

© Siemens AG 2013

PC-based Automation
SIMATIC PC-based controllers
SIMATIC WinAC ODK

■ Overview

■ Technical specifications
6ES7806-1CC03-0BA0
SIMATIC WinAC ODK V4.2
Hardware requirements
Hardware required

Required memory on hard disk, min.

30 Mbyte

Main memory, min.

512 Mbyte

Processor

Intel Pentium 800 MHz

Operating systems
Windows XP

Yes; Professional, SP2 and SP3

Configuration
Open Development interfaces
• CCX (Custom Code Extension)

• SIMATIC WinAC software PLCs support powerful interfaces
which permit close meshing of the control task with PC-based
applications.
• WinAC ODK allows the user to develop applications or to
integrate already existing applications into the control task.

5

New with WinAC ODK V4.2:
• CCX interface:
- New SFB 65003 for asynchronous execution of
ODK applications
- Expansion of data access functions
- Creation of Windows DLL with C# and VB
• SMX interface:
- Access to the Shared Memory interface under
IntervalZero RTX
- Expansion of data access functions
- Creation of Windows applications with C# and VB
• Supports MS Visual Studio 2005 and 2008 (under Windows)

PC with color monitor, keyboard,
mouse or pointing device for
Windows

• CMI (Controller Management
Interface)

• SMX (Shared Memory Extension)

Weight
Weight, approx.

■ Ordering data
SIMATIC WinAC ODK V4.2

Yes; WinAC RTX 2008 (V4.4) or
higher; programming languages:
Microsoft Visual C++ V6.0 SP5 or
higher, .net 2003, 2005, 2008;
Microsoft Visual Basic 2005, 2008;
Microsoft Visual C# 2005, 2008
Yes; WinAC RTX 2005 SP2 (V4.3) or
higher; programming languages:
Microsoft Visual C++ V6.0 SP5 or
higher, .net 2003, 2005, 2008;
Microsoft Visual Basic V6.0 SP5 or
higher, .net 2003, 2005, 2008;
Microsoft Visual C# .net 2003, 2005,
2008
Yes; WinAC RTX 2008 (V4.4) or
higher; programming languages:
Microsoft Visual C++ V6.0 SP5 or
higher, .net 2003, 2005, 2008;
Microsoft Visual Basic 2005, 2008;
Microsoft Visual C# 2005, 2008
200 g

Order No.
6ES7806-1CC03-0BA0

for integration of C/C++ code in
WinAC PLCs, executable under
Windows XP SP2 or SP3; CD-ROM
with electronic documentation
Single license

■ More information
Brochures
Information material for downloading can be found in the
Internet:
http://www.siemens.com/simatic/printmaterial

5/90

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
Embedded Controller
Embedded Controller

■ Overview
SIMATIC IPC bundles
The SIMATIC IPC bundles are ready-to-use, combined
embedded PCs with the following SIMATIC software options:
• SIMATIC WinAC RTX
• SIMATIC WinAC RTX F
• SIMATIC WinCC flexible or WinCC RT Advanced
• Combinations with WinAC and WinCC
SIMATIC IPC227D and IPC277D bundles
SIMATIC IPC227D and SIMATIC IPC277D are also available with
ready-to-use, pre-installed SIMATIC software:
• SIMATIC WinCC RT Advanced
• SIMATIC WinAC RTX
• SIMATIC WinAC RTX F
• Combinations of SIMATIC WinAC (F) and WinCC
An embedded PC or embedded device is combined with
automation software (e.g. software PLC, HMI system, etc.) and
is ready-for-use.
Windows Embedded Standard or Windows Embedded
Compact is used as the operating system.
PC-based Automation comprises:
• Control
• Technology
• Visualization
• Data processing
• Communication
• Fail-safe
on a common embedded PC platform.
S7-mEC
SIMATIC S7-mEC is a modular controller in S7-300 design with
powerful embedded PC technology. The embedded controller
combines the advantages of the tried-and-tested modular S7
controller with PC technology in one new device.
SIMATIC S7-mEC RTX is characterized by:
• Maximum ruggedness without fan or hard disk
• Modular expansion options, e.g. central expansion
with S7-300 I/O or PC interfaces
• Commissioning, as for S7-300, by automation specialists
• SIMATIC WinAC RTX or alternatively WinAC RTX F preinstalled
as a software PLC.

The panels are available in 7", 9", 12", 15" and 19" TFT touch
operation. With their compact structure, these SIMATIC IPCs are
the ideal solution for simple control and HMI tasks on a single
platform and also offer the openness of a PC-based system.
SIMATIC IPC477C bundles
As in the case of SIMATIC IPC427C, the SIMATIC HMI IPC477C
can also be ordered with ready-to-use, pre-installed
SIMATIC software:
• SIMATIC WinCC flexible or WinCC RT Advanced
• SIMATIC WinAC RTX
• SIMATIC WinAC RTX F
• Combinations of SIMATIC WinAC RTX (F) and WinCC
The panels are available in 12", 15" and 19" front variants,
optionally with touch or key functionality. With their compact
structure, Panel PCs are the ideal solution for complex control
and HMI tasks on a single platform and also offer the openness
of a PC-based system.
SIMATIC IPC477D bundles
As in the case of SIMATIC IPC427D, the SIMATIC IPC477D can
also be ordered with ready-to-use, pre-installed SIMATIC
software:
• SIMATIC WinCC RT Advanced
• SIMATIC WinAC RTX
• SIMATIC WinAC RTX F
• Combinations of SIMATIC WinAC RTX (F) and WinCC
The panels are available in 12" TFT Touch, 15" TFT Touch, 15"
TFT Touch/Key, 19" TFT Touch and 22" TFT Touch front variants.
With their compact structure, Panel PCs are the ideal solution for
complex control and HMI tasks on a single platform and also
offer the openness of a PC-based system.

Siemens ST 80 / ST PC · 2013

5/91

5

© Siemens AG 2013

PC-based Automation
Embedded Controller
Embedded Controller

■ More information (continued)
Decision aid for the use of embedded systems
Customer benefits

Modular Control

PC-based Automation

SIMATIC S7

S7 Modular
Embedded
Controller
(S7-mEC)

IPC227D,
IPC277D bundles

IPC427C/D bundles,
HMI IPC477C/
IPC477D bundles

on SIMATIC PC

Ruggedness

••

•

•

•

• (depends on hardware configuration)

Type of construction

Modular

Modular

Compact

Compact

Depending on the
type of construction

Spare parts availability
(beyond date of discontinuation)

10 years

5 years

5 years

5 years

5 years

Design

Performance
Fast restart after power failure

•

-

-

-

-

Hard real-time

••

••

••

••

••

Fast program processing

•

••

••
(depending on
processor)

••
(depending on
processor)

•••
(depending on
processor)

Safety Integrated

•

••
(option)

••
(option)

••
(option)

••

••/••

•/••

-/••

•/••
4x7D: - / • •

-/••

•

•

•

•

-

I/O interfacing
Central/distributed
User know-how
Preconfigured, turnkey
Previous knowledge

5

PLC

•••

••

•

•

•

PC

-

•

••

••

•••

HMI

-

o

o

o

••

-

•

•

•

•

Modularization with distributed
intelligence (CBA)

•

•

•

•

•

Integration of PLC and HMI on one
hardware platform

-

•

•

•

•

Openness
Openness
• Integration of C++ programs
• Further processing of data using
external programs via OPC on a
hardware platform

• Applies
o Applies under certain conditions
- Does not apply

■ More information
Brochures
Information material for downloading can be found in the
Internet:
http://www.siemens.com/simatic/printmaterial

5/92

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
Embedded Controller
EC31

■ Overview
• Get off to a fast start in automation solutions with embedded
PC platforms.
- Ready-to-use SIMATIC WinAC RTX or WinAC RTX F
preinstalled on EC31
- Prepared for use in a SIMATIC environment with
PROFINET and Industrial Ethernet
- Commissioning by specialist automation personnel as with
the S7-300
- Configuring and programming with SIMATIC STEP 7 over
Industrial Ethernet
- Optional visualization
• Modular expansion capability:
Central expansion with
- S7-300 I/O (SM modules of S7-300)
- Expansion modules for additional PC interfaces, e.g. DVI-I,
USB, Gigabit Ethernet networks and memory card slots,
as well as PCI-104
• Rugged operation
- Hard-disk-free operation based on flash disk and Windows
Embedded Standard
- Fan-free operation
• Flexibility of a PC-based automation environment
- Free memory space on flash disk can be used for other
PC applications
- Use of WinAC ODK with SIMATIC WinAC RTX and
WinAC RTX F (read-only in safety-related program part)
- Connection option for USB devices
- Memory capacity expandable using multimedia card
• Data retentivity for WinAC RTX and RTX F without
uninterruptible power supply (UPS)

■ Technical specifications
6ES7677-1DD100BA0

6ES7677-1DD100BB0

6ES7677-1FD100FB0

6ES7677-1DD100BF0

6ES7677-1DD100BG0

6ES7677-1DD100BH0

SIMATIC
S7-mEC, EC31

S7-mEC,
EC31-RTX

S7-mEC,
EC31-RTX F

S7-mEC, EC31HMI/RTX 128PT

S7-mEC, EC31HMI/RTX 512PT

S7-mEC, EC31HMI/RTX 2048PT

General information
Hardware product version

01

01

01

01

01

01

Firmware version

V2.0

V2.0

V2.0

V2.0

V2.0

V2.0

SIMATIC S7 modular embedded
controller

SIMATIC S7 modular embedded
controller

SIMATIC S7 modular embedded
controller

SIMATIC S7 modular embedded
controller

SIMATIC S7 modular embedded
controller

SIMATIC S7 modular embedded
controller

Processor selection

Intel Core Duo
1.2 GHz

Intel Core Duo
1.2 GHz

Intel Core Duo
1.2 GHz

Intel Core Duo
1.2 GHz

Intel Core Duo
1.2 GHz

Intel Core Duo
1.2 GHz

Main memory

1 GB RAM

1 GB RAM

1 GB RAM

1 GB RAM

1 GB RAM

1 GB RAM

Operating systems

Windows Embedded Standard
2009

Windows Embedded Standard
2009

Windows Embedded Standard
2009

Windows Embedded Standard
2009

Windows Embedded Standard
2009

Windows Embedded Standard
2009

SIMATIC WinAC
RTX 2010
Yes

SIMATIC WinAC
RTX F 2010
Yes

WinCC flexible
RT 2008 SP2,
incl. Sm@rtAccess, recipes,
archives options
SIMATIC WinAC
RTX 2010
Yes

WinCC flexible
RT 2008 SP2,
incl. Sm@rtAccess, recipes,
archives options
SIMATIC WinAC
RTX 2010
Yes

WinCC flexible
RT 2008 SP2,
incl. Sm@rtAccess, recipes,
archives options
SIMATIC WinAC
RTX 2010
Yes

34 W

34 W

34 W

34 W

34 W

PC configuration
Computer platform

Installed software
• Visualization

• Control
• Communication
Power losses
Power loss, typ.

34 W

Siemens ST 80 / ST PC · 2013

5/93

5

© Siemens AG 2013

PC-based Automation
Embedded Controller
EC31

■ Technical specifications (continued)

Memory
Memory type

Work memory
• integrated

6ES7677-1DD100BA0

6ES7677-1DD100BB0

6ES7677-1FD100FB0

6ES7677-1DD100BF0

6ES7677-1DD100BG0

6ES7677-1DD100BH0

SIMATIC
S7-mEC, EC31

S7-mEC,
EC31-RTX

S7-mEC,
EC31-RTX F

S7-mEC, EC31HMI/RTX 128PT

S7-mEC, EC31HMI/RTX 512PT

S7-mEC, EC31HMI/RTX 2048PT

256 KB non-volatile memory for
retentive data

512 KB non-volatile memory for
retentive data

512 KB non-volatile memory for
retentive data

512 KB non-volatile memory for
retentive data

512 KB non-volatile memory for
retentive data

512 KB non-volatile memory for
retentive data

1 Gbyte

1 Gbyte

1 Gbyte

1 Gbyte

1 Gbyte

1 Gbyte

CPU processing times
for bit operations, typ.

0.004 µs; typ.

0.004 µs; typ.

0.004 µs; typ.

0.004 µs; typ.

0.004 µs; typ.

for fixed point arithmetic, typ.

0.003 µs; typ.

0.003 µs; typ.

0.003 µs; typ.

0.003 µs; typ.

0.003 µs; typ.

for floating point arithmetic, typ.

0.004 µs; typ.

0.004 µs; typ.

0.004 µs; typ.

0.004 µs; typ.

0.004 µs; typ.

Max. code size
and max. data
size: 4 MB each
64 kbyte

Max. code size
and max. data
size: 4 MB each
64 kbyte

Max. code size
and max. data
size: 4 MB each
64 kbyte

Max. code size
and max. data
size: 4 MB each
64 kbyte

Max. code size
and max. data
size: 4 MB each
64 kbyte

Max. code size
and max. data
size: 4 MB each
64 kbyte

Max. code size
and max. data
size: 4 MB each
64 kbyte

Max. code size
and max. data
size: 4 MB each
64 kbyte

Max. code size
and max. data
size: 4 MB each
64 kbyte

Max. code size
and max. data
size: 4 MB each
64 kbyte

Max. code size
and max. data
size: 4 MB each
64 kbyte

Max. code size
and max. data
size: 4 MB each
64 kbyte

Max. code size
and max. data
size: 4 MB each
64 kbyte

Max. code size
and max. data
size: 4 MB each
64 kbyte

Max. code size
and max. data
size: 4 MB each
64 kbyte

• Number of synchronous error OBs

64 kbyte
2; OB 100, 102
7; OB 80, 82-85,
86, 88
2; OB 121, 122

64 kbyte
2; OB 100, 102
7; OB 80, 82-85,
86, 88
2; OB 121, 122

64 kbyte
2; OB 100, 102
7; OB 80, 82-85,
86, 88
2; OB 121, 122

64 kbyte
2; OB 100, 102
7; OB 80, 82-85,
86, 88
2; OB 121, 122

64 kbyte
2; OB 100, 102
7; OB 80, 82-85,
86, 88
2; OB 121, 122

Nesting depth
• per priority class
• additional within an error OB

24
24

24
24

24
24

24
24

24
24

2 048

2 048

2 048

2 048

2 048

Yes
0
2 047
8

Yes
0
2 047
8

Yes
0
2 047
8

Yes
0
2 047
8

Yes
0
2 047
8

Yes
0
999

Yes
0
999

Yes
0
999

Yes
0
999

Yes
0
999

Yes
SFB

Yes
SFB

Yes
SFB

Yes
SFB

Yes
SFB

CPU-blocks
DB
• Number, max.

• Size, max.
FB
• Number, max.

• Size, max.
FC
• Number, max.

• Size, max.

5

OB
• Size, max.
• Number of startup OBs
• Number of asynchronous error OBs

Counters, timers and
their retentivity
S7 counter
• Number
• Retentivity
- adjustable
- lower limit
- upper limit
- preset
• Counting range
- adjustable
- lower limit
- upper limit
IEC counter
• present
• Type

5/94

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
Embedded Controller
EC31

■ Technical specifications (continued)
6ES7677-1DD100BA0

6ES7677-1DD100BB0

6ES7677-1FD100FB0

6ES7677-1DD100BF0

6ES7677-1DD100BG0

6ES7677-1DD100BH0

SIMATIC
S7-mEC, EC31

S7-mEC,
EC31-RTX

S7-mEC,
EC31-RTX F

S7-mEC, EC31HMI/RTX 128PT

S7-mEC, EC31HMI/RTX 512PT

S7-mEC, EC31HMI/RTX 2048PT

2 048

2 048

2 048

2 048

2 048

Yes
0
2 047

Yes
0
2 047

Yes
0
2 047

Yes
0
2 047

Yes
0
2 047

10 ms
9 990 s

10 ms
9 990 s

10 ms
9 990 s

10 ms
9 990 s

10 ms
9 990 s

IEC timer
• present
• Type

Yes
SFB

Yes
SFB

Yes
SFB

Yes
SFB

Yes
SFB

Data areas and their retentivity
retentive data area, total

512 KB

512 KB

512 KB

512 KB

512 KB

Flag
• Number, max.
• Retentivity preset
• Number of clock memories

16 kbyte
MB 0 to MB 15
8

16 kbyte
MB 0 to MB 15
8

16 kbyte
MB 0 to MB 15
8

16 kbyte
MB 0 to MB 15
8

16 kbyte
MB 0 to MB 15
8

16 kbyte
16 kbyte

16 kbyte
16 kbyte

16 kbyte
16 kbyte

16 kbyte
16 kbyte

16 kbyte
16 kbyte

8 kbyte
8 kbyte

8 kbyte
8 kbyte

8 kbyte
8 kbyte

8 kbyte
8 kbyte

8 kbyte
8 kbyte

Process image
• Inputs, adjustable
• Outputs, adjustable
• Inputs, default
• Outputs, default

16 kbyte
16 kbyte
512 byte
512 byte

16 kbyte
16 kbyte
512 byte
512 byte

8 kbyte
8 kbyte
512 byte
512 byte

8 kbyte
8 kbyte
512 byte
512 byte

8 kbyte
8 kbyte
512 byte
512 byte

Subprocess images
• Number of subprocess images, max.

15

15

15

15

15

Digital channels
• Inputs
• Outputs

128 000
128 000

128 000
128 000

128 000
128 000

128 000
128 000

128 000
128 000

Analog channels
• Inputs
• Outputs

8 000
8 000

8 000
8 000

8 000
8 000

8 000
8 000

8 000
8 000

Time of day
Clock
• Hardware clock (real-time clock)

Yes

Yes;
Resolution: 1 s

Yes

Yes

Yes

Clock synchronization
• supported
• to PC-CP, slave
• on Ethernet via NTP

Yes
Yes
Yes

Yes
Yes
Yes

Yes
Yes
Yes

Yes
Yes
Yes

Yes
Yes
Yes

S7 times
• Number
• Retentivity
- adjustable
- lower limit
- upper limit
• Time range
- lower limit
- upper limit

Address area
I/O address area
• Inputs
• Outputs
• of which, distributed
- Inputs
- Outputs

5

Interfaces
Number of USB interfaces

2

2

2

2

2

serial interface

0

0

0

0

0

X1: 2 ports
10/100 Mbit/s
(ERTEC-based)
X2: 1 port
10/100 Mbit/s

X1: 2 ports
10/100 Mbit/s
(ERTEC-based)
X2: 1 port
10/100 Mbit/s

X1: 2 ports
10/100 Mbit/s
(ERTEC-based)
X2: 1 port
10/100 Mbit/s

X1: 2 ports
10/100 Mbit/s
(ERTEC-based)
X2: 1 port
10/100 Mbit/s

X1: 2 ports
10/100 Mbit/s
(ERTEC-based)
X2: 1 port
10/100 Mbit/s

Industrial Ethernet
• Industrial Ethernet interface

X1: 2 ports
10/100 Mbit/s
(ERTEC-based)
X2: 1 port
10/100 Mbit/s

Siemens ST 80 / ST PC · 2013

5/95

© Siemens AG 2013

PC-based Automation
Embedded Controller
EC31

■ Technical specifications (continued)
6ES7677-1DD100BA0

6ES7677-1DD100BB0

6ES7677-1FD100FB0

6ES7677-1DD100BF0

6ES7677-1DD100BG0

6ES7677-1DD100BH0

SIMATIC
S7-mEC, EC31

S7-mEC,
EC31-RTX

S7-mEC,
EC31-RTX F

S7-mEC, EC31HMI/RTX 128PT

S7-mEC, EC31HMI/RTX 512PT

S7-mEC, EC31HMI/RTX 2048PT

1st interface
Type of interface

PROFINET

PROFINET

PROFINET

PROFINET

PROFINET

Physics

2x RJ45

2x RJ45

2x RJ45

2x RJ45

2x RJ45

Automatic detection of transmission
speed

Yes

Yes

Yes

Yes

Yes

Autonegotiation

Yes

Yes

Yes

Yes

Yes

Autocrossing

Yes

Yes

Yes

Yes

Yes

Number of connection resources

32

32

32

32

32

No
Yes
Yes

No
Yes
Yes

No
Yes
Yes

Functionality
• MPI
• DP master
• DP slave
• PROFINET IO Device
• PROFINET IO Controller
• PROFINET CBA
• Point-to-point connection

5

PROFINET IO Controller
• Number of connectable IO devices,
max.
• Max. number of connectable
IO devices for RT
- of which in line, max.
• Number of IO devices with IRT
and the option "high flexibility"
- of which in line, max.
• Number of IO Devices with IRT and
the option "high performance", max.
- of which in line, max.
• IRT, supported
• Prioritized startup supported
- Number of IO Devices, max.
• Activation/deactivation of IO Devices
- Maximum number of IO devices
that can be activated/deactivated
at the same time.
• IO Devices changing during operation (partner ports), supported
- Max. number of IO devices
per tool
• Device replacement without swap
medium
• Send cycles

• Updating times

• Services
- PG/OP communication
- S7 routing
- S7 communication
- Isochronous mode
• Address area
- Inputs, max.
- Outputs, max.
- User data per address area, max.
- User data consistency, max.

5/96

Siemens ST 80 / ST PC · 2013

No
Yes
Yes

No
No
No
No
Yes
Yes
No

256

256

256

256

256

256

256

256

256

256

256
256

256
256

256
256

256
256

256
256

61
256

61
256

61
256

61
256

61
256

64
Yes
Yes
32
Yes
8

64
Yes
Yes
32
Yes
8

64
Yes
Yes
32
Yes
8

64
Yes
Yes
32
Yes
8

64
Yes
Yes
32
Yes
8

Yes

Yes

Yes

Yes

Yes

8

8

8

8

8

Yes

Yes

Yes

Yes

Yes

Adjustable:
250 µs, 500 µs
and 1 ms
250 µs - 128 ms
(with signal cycle
250 µs); 500 µs 256 ms (with signal cycle 500 µs);
1 ms - 512 ms
(with signal cycle
1 ms)

Adjustable:
250 µs, 500 µs
and 1 ms
250 µs - 128 ms
(with signal cycle
250 µs); 500 µs 256 ms (with signal cycle 500 µs);
1 ms - 512 ms
(with signal cycle
1 ms)

Adjustable:
250 µs, 500 µs
and 1 ms
250 µs - 128 ms
(with signal cycle
250 µs); 500 µs 256 ms (with signal cycle 500 µs);
1 ms - 512 ms
(with signal cycle
1 ms)

Adjustable:
250 µs, 500 µs
and 1 ms
250 µs - 128 ms
(with signal cycle
250 µs); 500 µs 256 ms (with signal cycle 500 µs);
1 ms - 512 ms
(with signal cycle
1 ms)

Adjustable:
250 µs, 500 µs
and 1 ms
250 µs - 128 ms
(with signal cycle
250 µs); 500 µs 256 ms (with signal cycle 500 µs);
1 ms - 512 ms
(with signal cycle
1 ms)

Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes

16 kbyte
16 kbyte
2 kbyte
256 byte

16 kbyte
16 kbyte
2 kbyte
256 byte

16 kbyte
16 kbyte
2 kbyte
256 byte

16 kbyte
16 kbyte
2 kbyte
256 byte

16 kbyte
16 kbyte
2 kbyte
256 byte

© Siemens AG 2013

PC-based Automation
Embedded Controller
EC31

■ Technical specifications (continued)
6ES7677-1DD100BA0

6ES7677-1DD100BB0

6ES7677-1FD100FB0

6ES7677-1DD100BF0

6ES7677-1DD100BG0

6ES7677-1DD100BH0

SIMATIC
S7-mEC, EC31

S7-mEC,
EC31-RTX

S7-mEC,
EC31-RTX F

S7-mEC, EC31HMI/RTX 128PT

S7-mEC, EC31HMI/RTX 512PT

S7-mEC, EC31HMI/RTX 2048PT

Yes
32
0, 20, 21, 23, 25,
80, 102, 135,
161, 8080,
34962, 34963,
34964, 65532,
65533, 65534,
65535

Yes
32
0, 20, 21, 23, 25,
80, 102, 135,
161, 8080,
34962, 34963,
34964, 65532,
65533, 65534,
65535

Yes
32
0, 20, 21, 23, 25,
80, 102, 135,
161, 8080,
34962, 34963,
34964, 65532,
65533, 65534,
65535

Yes
32
0, 20, 21, 23, 25,
80, 102, 135,
161, 8080,
34962, 34963,
34964, 65532,
65533, 65534,
65535

Yes
32
0, 20, 21, 23, 25,
80, 102, 135,
161, 8080,
34962, 34963,
34964, 65532,
65533, 65534,
65535

Yes; DCP

Yes; DCP

Yes; DCP

Yes; DCP

Yes; DCP

Yes; DCP

Yes; DCP

Yes; DCP

Yes; DCP

Yes; DCP

Yes; DCP

Yes; DCP

Yes; DCP

Yes; DCP

Yes; DCP

Yes; LLDP, LLDP
MIB, SNMP
Yes; Standard
MIB II, SNMP

Yes; LLDP, LLDP
MIB, SNMP
Yes; Standard
MIB II, SNMP

Yes; LLDP, LLDP
MIB, SNMP
Yes; Standard
MIB II, SNMP

Yes; LLDP, LLDP
MIB, SNMP
Yes; Standard
MIB II, SNMP

Yes; LLDP, LLDP
MIB, SNMP
Yes; Standard
MIB II, SNMP

Integrated Ethernet interface

Integrated Ethernet interface

Integrated Ethernet interface

Integrated Ethernet interface

Integrated Ethernet interface

Physics

Ethernet RJ45

Ethernet RJ45

Ethernet RJ45

Ethernet RJ45

Ethernet RJ45

Automatic detection of transmission
speed

Yes

Yes

Yes

Yes

Yes

Autonegotiation

Yes

Yes

Yes

Yes

Yes

Autocrossing

No

No

No

No

No

Number of connection resources

32

32

32

32

32

Functionality
• PROFINET IO Controller
• PROFINET IO Device
• PROFINET CBA

No
No
No

No
No
No

No
No
No

No
No
No

No
No
No

Yes; DCP

Yes; DCP

Yes; DCP

Yes; DCP

Yes; DCP

Yes; DCP

Yes; DCP

Yes; DCP

Yes; DCP

Yes; DCP

Yes; DCP

Yes; DCP

Yes; DCP

Yes; DCP

Yes; DCP

• Extended network diagnostics
with Standard MIB II, supported

Yes; LLDP, LLDP
MIB, SNMP
Yes; Standard
MIB II, SNMP

Yes; LLDP, LLDP
MIB, SNMP
Yes; Standard
MIB II, SNMP

Yes; LLDP, LLDP
MIB, SNMP
Yes; Standard
MIB II, SNMP

Yes; LLDP, LLDP
MIB, SNMP
Yes; Standard
MIB II, SNMP

Yes; LLDP, LLDP
MIB, SNMP
Yes; Standard
MIB II, SNMP

Communication functions
PG/OP communication

Yes

Yes

Yes

Yes

Yes

Global data communication
• supported

No

No

No

No

No

S7 basic communication
• supported

No

No

No

No

No

S7 communication
• supported
• as server
• as client

Yes
Yes
Yes

Yes
Yes
Yes

Yes
Yes
Yes

Yes
Yes
Yes

Yes
Yes
Yes

Open IE communication
• Open IE communication, supported
• Number of connections, max.
• Local port numbers used
at the system end

PROFINET functions
• Detection of accessible nodes,
supported
• Assignment of the IP address,
supported
• Assignment of the device name,
supported
• Topology recognition, supported
• Extended network diagnostics
with Standard MIB II, supported
2nd interface
Type of interface

PROFINET functions
• Detection of accessible nodes,
supported
• Assignment of the IP address,
supported
• Assignment of the device name,
supported
• Topology recognition, supported

Siemens ST 80 / ST PC · 2013

5

5/97

© Siemens AG 2013

PC-based Automation
Embedded Controller
EC31

■ Technical specifications (continued)
6ES7677-1DD100BA0

6ES7677-1DD100BB0

6ES7677-1FD100FB0

6ES7677-1DD100BF0

6ES7677-1DD100BG0

6ES7677-1DD100BH0

SIMATIC
S7-mEC, EC31

S7-mEC,
EC31-RTX

S7-mEC,
EC31-RTX F

S7-mEC, EC31HMI/RTX 128PT

S7-mEC, EC31HMI/RTX 512PT

S7-mEC, EC31HMI/RTX 2048PT

Yes;
Via integrated
PROFINET interface (X1) and
loadable FBs
32
32 kbyte
Yes;
Via integrated
PROFINET interface (X1) and
loadable FBs
32
32 kbyte
Yes;
Via integrated
PROFINET interface (X1) and
loadable FBs
32
1 472 byte

Yes;
Via integrated
PROFINET interface (X1) and
loadable FBs
32
32 kbyte
Yes;
via integrated
PROFINET interface and loadable FBs
32
32 kbyte
Yes;
Via integrated
PROFINET interface (X1) and
loadable FBs
32
1 472 byte

Yes;
Via integrated
PROFINET interface (X1) and
loadable FBs
32
32 kbyte
Yes;
Via integrated
PROFINET interface (X1) and
loadable FBs
32
32 kbyte
Yes;
Via integrated
PROFINET interface (X1) and
loadable FBs
32
1 472 byte

Yes;
Via integrated
PROFINET interface (X1) and
loadable FBs
32
32 kbyte
Yes;
Via integrated
PROFINET interface (X1) and
loadable FBs
32
32 kbyte
Yes;
Via integrated
PROFINET interface (X1) and
loadable FBs
32
1 472 byte

Yes;
Via integrated
PROFINET interface (X1) and
loadable FBs
32
32 kbyte
Yes;
Via integrated
PROFINET interface (X1) and
loadable FBs
32
32 kbyte
Yes;
Via integrated
PROFINET interface (X1) and
loadable FBs
32
1 472 byte

62; The alarm
functions cannot
currently be used
for central bus
modules

62; The alarm
functions cannot
currently be used
for central bus
modules

62; The alarm
functions cannot
currently be used
for central bus
modules

62; The alarm
functions cannot
currently be used
for central bus
modules

62; The alarm
functions cannot
currently be used
for central bus
modules

Process diagnostic messages

Yes; Alarm_S

Yes; Alarm_S

Yes; Alarm_S

Yes; Alarm_S

Yes; Alarm_S

Test commissioning functions
Status/control
• Status/control variable

Yes

Yes

Yes

Yes

Yes

Forcing
• Forcing

No

No

No

No

No

Diagnostic buffer
• present

Yes

Yes

Yes

Yes

Yes

0 °C
50 °C

0 °C
50 °C

0 °C
50 °C

0 °C
50 °C

0 °C
50 °C

Yes
Yes
Yes
Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes
Yes
Yes
Yes

Open IE communication
• TCP/IP

- Number of connections, max.
- Data length, max.
• ISO-on-TCP (RFC1006)

- Number of connections, max.
- Data length, max.
• UDP

- Number of connections, max.
- Data length, max.
S7 message functions
Number of login stations for message
functions, max.

5

Ambient conditions
Operating temperature
• Min.
• max.

0 °C
50 °C

Configuration
programming
• Programming language
- LAD
- FBD
- STL
- SCL
- CFC
- GRAPH
- HiGraph®
Dimensions
Width

160 mm

160 mm

160 mm

160 mm

160 mm

160 mm

Height

125 mm

125 mm

125 mm

125 mm

125 mm

125 mm

Depth

115 mm

115 mm

115 mm

115 mm

115 mm

115 mm

Weight
Weight, approx.

1.5 kg

1.5 kg

1.5 kg

1.5 kg

1.5 kg

1.5 kg

5/98

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
Embedded Controller
EC31

■ Ordering data

Order No.

SIMATIC S7-modular
Embedded Controller
EC31

EM PCI-104 expansion module
6ES7677-1DD10-0BA0

Intel CoreDuo 1.2 GHz processor
Memory configuration:
1 GB RAM, 4 GB Flash Disk;
interfaces:
1 Industrial Ethernet port,
2 PROFINET ports, 2 USB ports,
1 slot for multimedia card;
Software:
Windows Embedded Standard preinstalled, Software Development Kit
(SDK) for creating C/C++ applications with accesses to central
I/O modules
EC31-RTX

Order No.
Accessories
6ES7677-1DD60-1AA0

For fitting up to 3 additional
PCI-104 cards
EM PC expansion module

6ES7677-1DD50-2AA0

Additional connection options:
2 USB interfaces, 1 Gigabit Ethernet
interface, 1 serial interface, 1 slot for
CF card, 1 slot for SD card/Micro
Memory Card

6ES7677-1DD10-0BB0

Intel CoreDuo 1.2 GHz processor
Memory configuration:
1 GB RAM, 4 GB Flash Disk;
interfaces:
1 Industrial Ethernet port,
2 PROFINET ports, 2 USB ports,
1 slot for multimedia card;
Software:
Windows Embedded Standard and
WinAC RTX 2010 preinstalled
EC31-RTX F

6ES7677-1FD10-0FB0

Intel CoreDuo 1.2 GHz processor
Memory configuration:
1 GB RAM, 4 GB Flash Disk;
interfaces:
1 Industrial Ethernet port,
2 PROFINET ports, 2 USB ports,
1 slot for multimedia card;
Software:
Windows Embedded Standard and
WinAC RTX F 2010 preinstalled

5

EC31-HMI/RTX
Intel CoreDuo 1.2 GHz processor
Memory configuration:
1 GB RAM, 4 GB Flash Disk;
interfaces:
1 Industrial Ethernet port,
2 PROFINET ports, 2 USB ports,
1 slot for multimedia card;
Software:
Windows Embedded Standard,
WinAC RTX 2010, SIMATIC
SOFTNET-S7/V7.0 Lean preinstalled
• With WinCC flexible 2008 RT
128 PT
• With WinCC flexible 2008 RT
512 PT
• With WinCC flexible 2008 RT
2048 PT

6ES7677-1DD10-0BF0
6ES7677-1DD10-0BG0
6ES7677-1DD10-0BH0

Siemens ST 80 / ST PC · 2013

5/99

© Siemens AG 2013

PC-based Automation
Embedded Controller
Expansion modules

■ Overview

■ Technical specifications
6ES76771DD60-1AA0

6ES76771DD50-2AA0

EM PCI-104

EM PC

General information
Hardware product version

01

01

Input current
from expansion bus

100 mA

580 mA

2.4 W; Without
inserted PCI-104
cards

9W

Power losses
Power loss, typ.

14 W

Power loss, max.
Interfaces
Number of USB interfaces

0

2

serial interface

0

1x V.24 (RS232)

Industrial Ethernet
• Industrial Ethernet interface

• Expansion modules for SIMATIC S7-modular Embedded
Controller EC31
- EM PCI-104 for additionally accommodating up to
3 PCI-104 cards
- EM PC with additional PC interfaces and slots for memory
media

Ambient conditions
Operating temperature
• Min.
• max.

0 °C
50 °C

0 °C
50 °C

120 mm; Without bus connector ExtensionBus

80 mm; Without
bus connector
Extension-Bus

Height

125 mm; Without external voltage connecting
terminal

125 mm

Depth

115 mm

115 mm

Weight
Weight, approx.

0.5 kg

0.4 kg

Dimensions
Width

5

Onboard, 10/
100/1000 Mbit,
RJ45

■ Ordering data
EM PCI-104 expansion module

Order No.
6ES7677-1DD60-1AA0

For fitting up to 3 additional
PCI-104 cards
EM PC expansion module
Additional connection options:
1 DVI-I interface, 2 USB interfaces,
1 Gigabit Ethernet interface, 1 serial
interface, 1 slot for CF card, 1 slot
for SD card/Micro Memory Card

5/100

Siemens ST 80 / ST PC · 2013

6ES7677-1DD50-2AA0

© Siemens AG 2013

PC-based Automation
Embedded bundles/Software packages
Embedded bundles/Software packages

■ Overview
The Embedded Bundles for PC-based Automation are based on
rugged, fan-free SIMATIC IPCs. They are pre-installed,
configured, and ready-to-use with the SIMATIC WinAC RTX (F)
software controller and/or the SIMATIC WinCC/WinCC flexible
visualization software.

■ More information
You can find more information on the Internet at:
http://www.automation.siemens.com/mcms/pc-basedautomation/en/embedded-bundles

Software packages with WinCC or WinAC together with the
corresponding SIMATIC IPC.
The following are available:
• SIMATIC IPC packages with WinCC flexible
• SIMATIC IPC packages with WinCC RT Advanced
(TIA Portal)
• SIMATIC IPC Packages with WinCC
• SIMATIC IPC packages with WinCC RT Professional
(TIA Portal)
• SIMATIC IPC packages with WinAC RTX (F)
A Software Package can only be supplied if the same number
of SIMATIC industrial PCs is ordered together with the software.
It cannot be ordered subsequently.

5

Siemens ST 80 / ST PC · 2013

5/101

© Siemens AG 2013

PC-based Automation
Embedded bundles/Software packages
SIMATIC IPC227D bundles

■ Overview
• A quick start in automation solutions with embedded PC
platforms
- SIMATIC WinAC RTX or SIMATIC WinAC RTX F preinstalled
on SIMATIC IPC227D and ready for use
- PROFINET RT and Industrial Ethernet pre-configured for use
in a SIMATIC environment
- Optional WinCC RT Advanced for visualization tasks in
parallel with SIMATIC WinAC RTX
- Configuration and programming with SIMATIC STEP 7 via
Industrial Ethernet or PROFINET
• Safety requirements up to SIL 3 in accordance with
IEC 61508/62061 or EN ISO 13849-1 up to PL e can be
implemented with WinAC RTX F.
• Rugged operation
- Hard-disk-free operation with CompactFlash card (CF card)
or solid-state drive and Windows Embedded Standard 2009
or Windows Embedded Standard 7, 32-bit
- Fan-free operation
- 128 KB of retentive data for WinAC RTX,
also without uninterruptible power supply (UPS)
• Flexibility of a PC-based automation environment
- Use of WinAC ODK with SIMATIC WinAC RTX or
SIMATIC WinAC RTX F (read-only for fail-safe program
section)
- Connection option for USB devices, flat panel monitor or
screen
- PCIe cards can be plugged in

■ Technical specifications
See "PC-based Automation -> Box PC -> SIMATIC IPC227D".

■ Ordering data
For Selection and ordering data see
SIMATIC Box PC -> SIMATIC IPC227D

5

■ More information
Delivery
Production and delivery of the devices will typically be
completed within 15 business days after receipt of order. The
hardware and mass memory with the complete, pre-installed,
ready-to-use software are supplied fully assembled.

5/102

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
Embedded bundles/Software packages
SIMATIC IPC427D bundles

■ Overview
SIMATIC IPC427D (Microbox PC):
The powerful embedded IPC – maintenance-free
with versatile configuration
Ready-to-run, complete solutions (software is already installed
and preconfigured) for visualization and automation in
connection with WinCC RT Advanced and/or WinAC RTX.
• Ultra-compact
• Maintenance-free
• Third generation Intel Core i technology
• Current product versions of the pre-installed software:
- SIMATIC WinCC RT Advanced V12
- SIMATIC WinAC RTX 2010
- SIMATIC Net V8.x

■ Technical specifications
See "PC-based Automation -> Box PC -> SIMATIC IPC427D"

■ Ordering data
For selection and ordering data, see "SIMATIC Box PC ->
SIMATIC IPC427D"

■ More information
Delivery
Production and delivery of the devices will typically be
completed within 13 business days after receipt of order. The
hardware and mass memory with the complete, pre-installed,
ready-to-use software are supplied fully assembled.
Commissioning
Before the control or visualization application is complete,
simply perform the following steps:
• Optional: Installation and setup of additional software on the
device
• Optional: Installation and setup of other software on the device
• Transfer of the engineering projects from STEP 7 or
WinCC Advanced
• Transfer of the supplied license keys for SIMATIC software
• Backup of the installed software and protection of the flashbased mass memory by switching on the Enhance Write filter

5

Siemens ST 80 / ST PC · 2013

5/103

© Siemens AG 2013

PC-based Automation
Embedded bundles/Software packages
SIMATIC IPC427C bundles

■ Overview
Embedded PC platform with extremely high industrial compatibility for demanding tasks in the field of PC-based automation
• Rugged operation
- Operation without a hard disk, based on CompactFlash card
(CF Card) or solid-state drive and Windows Embedded
Standard
- Fan-free operation
- 128 KB of retentive data for WinAC RTX,
also without uninterruptible power supply (UPS)
• Flexibility of a PC-based automation environment
- Free memory space on CF Card can be used for other
PC applications
- Use of WinAC ODK with SIMATIC WinAC RTX or
SIMATIC WinAC RTX F (read-only for fail-safe program
section)
- Connection option for USB devices, flat panel monitor or
screen
- PCI 104 cards can be plugged in
• High-performance service concept
- Replacement parts for preferred types available ex stock
• Safety requirements up to SIL 3 in accordance with
IEC 61508/62061 or EN ISO 13849-1 up to PL e can be
implemented with WinAC RTX F.
• Cost-effective versions with PROFINET, based on the
standard Ethernet interface
• Current product versions of the pre-installed software:
- SIMATIC WinAC RTX 2010 or SIMATIC WinAC RTX F 2010
- SIMATIC WinCC flexible 2008 or WinCC RT Advanced
- and the combinations of the software packages above
- SIMATIC NET Edition 2008 or V8.1 (depending on operating
system), as well as
- SIMATIC WInCC V7.0 SP2 or WinCC RT Professional as a
client / single station

5

5/104

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
Embedded bundles/Software packages
SIMATIC IPC427C bundles

■ Ordering data

Order No.

Order No.

SIMATIC IPC427C bundles

HMI bundles with
WinCC flexible 2008 or
WinCC RT Advanced V11 bundles
HMI/RTX bundles
combining HMI and RTX
SIMATIC IPC427C
with pre-installed software
Processor
• Celeron M, 1.2 GHz,
2x PROFINET (IE) 1)
• Celeron M, 1.2 GHz,
2x PROFINET (IE), 1x PROFIBUS 1)
• Core2 Solo, 1.2 GHz,
2x PROFINET (IE) 1)
• Core2 Solo, 1.2 GHz,
2x PROFINET (IE), 1x PROFIBUS 1)
• Core2 Solo, 1.2 GHz,
1x PROFINET (IE),
PROFINET (RT/IRT) 3 ports
• Core2 Duo, 1.2 GHz,
2x PROFINET (IE) 1)
• Core2 Duo, 1.2 GHz,
• 2x PROFINET (IE),
1x PROFIBUS 1)
• Core2 Duo, 1.2 GHz, 1x PROFINET
(IE), PROFINET (RT/IRT) 3 ports
Main memory
• 1 GB RAM
• 2 GB RAM 1)
• 4 GB RAM
Operating system
• Windows Embedded Standard
2009 (WES2009) 1)
• Windows Embedded Standard 7
(WES7) 2)
Mass storage, internal
• None (can only be ordered
with externally accessible mass
storage) 1)
• 250 GB HDD SATA, only additionally with externally accessible CF
• 50 GB solid-state drive
(high-endurance), operating
system and software pre-installed
• 80 GB solid-state drive
(standard SATA), operating system
and software pre-installed
• 4 GB internal CompactFlash,
operating system and software
pre-installed 1)
• 8 GB internal CompactFlash,
operating system and software
pre-installed 1)
• 16 GB internal CompactFlash,
operating system and software
pre-installed 1)

6ES7675-1D 7 7 7 - 7 7 7 7

SIMATIC IPC427C
with pre-installed software
(continued)

RTX bundles with
SIMATIC WinAC RTX (F) 2010

6ES7675-1D 7 7 7 - 7 7 7 7

A
B

Externally accessible mass storage
• None (can only be ordered
with internal mass storage) 1)
• 4 GB CompactFlash,
operating system and
software pre-installed 1)
• 8 GB CompactFlash,
operating system and
software pre-installed 1)
• 16 GB internal CompactFlash,
operating system and software
pre-installed 1)
Software configurations 1)
• WinAC RTX
• HMI RT 128 PT
• HMI RT 512 PT
• HMI RT 2048 PT
• HMI RT 4096 PT
• WinAC RTX, HMI RT 128 PT
• WinAC RTX, HMI RT 512 PT
• WinAC RTX, HMI RT 2048 PT
• WinAC RTX, HMI RT 4096 PT
• WinAC RTX F
• WinAC RTX F, HMI RT 128 PT
• WinAC RTX F, HMI RT 512 PT
• WinAC RTX F, HMI RT 2048 PT
• WinAC RTX F, HMI RT 4096 PT

E
F
G

J
K

L

2
3
4

• HMI RT: WinCC flexible 2008 3)
or w/o HMI software
• HMI RT: WinCC Advanced V11
SP2 (TIA Portal), only with WES7
and 2GB RAM

0

A
D

E

F

B
C
D
E
F
K
L
M
N
P
R
S
T
U
0
1

5

1

0

1
2

3

6

7

8

1)

Replacement hardware units available in exchange

2)

Only together from 2 GB main memory

3)

WinCC flexible 2008 SP2 with WES2009 and
WinCC flexible 2008 SP3 with WES7

Siemens ST 80 / ST PC · 2013

5/105

© Siemens AG 2013

PC-based Automation
Embedded bundles/Software packages
SIMATIC IPC427C bundles

■ Ordering data

Order No.

In-stock models
Replacement hardware units
available in exchange
SIMATIC IPC427C bundle with
WinAC RTX 2010
• Core2 Solo processor, 1.2 GHz,
2x PROFINET (IE), 1x PROFIBUS,
2 GB RAM, 4 GB CompactFlash
• Core2 Duo processor, 1.2 GHz,
2x PROFINET (IE), 1x PROFIBUS,
2 GB RAM, 4 GB CompactFlash
• Core2 Duo processor, 1.2 GHz,
2x PROFINET (IE), 1x PROFIBUS,
2 GB RAM, 8 GB CompactFlash
SIMATIC IPC427C bundle
with WinAC RTX 2010 and
WinCC flexible 2008 512 PT
• Core2 Duo processor, 1.2 GHz,
2x PROFINET (IE), 1x PROFIBUS,
2 GB RAM, 4 GB CompactFlash

("Built to order" with max. delivery
time of 14 working days; only repairs
are possible for hardware)
6ES7675-1DF30-0DB0

6ES7675-1DK30-0DB0

6ES7675-1DK30-0EP0

6ES7675-1DK30-0DL0

Bundles with WinCC

IPC427C with WinCC RT, V7.0
SP2, incl. Update 1
Fan-free, 4 x USB 2.0 (500 mA),
1 x COM (RS 232),
24 V DC power supply
with On/Off switch,
2 x PROFINET (IE),
Windows Embedded Standard 2009
pre-installed,
SIMATIC WinCC V7.0 SP2 incl.
Update1 Runtime pre-installed

5

Client and stand-alone station
configurations
• Core2 Solo processor 1.2 GHz,
8 GB CF card,
runtime license 128 PT1)
• Core2 Solo processor 1.2 GHz,
PROFIBUS DP,
2 GB SDRAM-DDR3,
8 GB CF card,
runtime license 128 PT1)
Stand-alone station
configurations
Core2 Duo processor 1.2 GHz,
PROFIBUS DP, 4 GB SDRAM-DDR3
• 8 GB CF card,
runtime license 128 PT1)
• 50 GB SSD (High Endurance),
runtime license 128 PT1)
• 8 GB CF card,
runtime license 2048 PT1)
• 50 GB SSD (High Endurance),
runtime license 2048 PT1)
1)

6ES7675-1DA20-6AX0

6ES7675-1DE30-7AX0

Client configurations
• Celeron M processor 1.2 GHz,
2 GB SDRAM DDR3,
8 GB CF card,
runtime license 128 PT 1)

Stand-alone station
configurations
Core2 Duo processor 1.2 GHz,
PROFIBUS DP, 4 GB SDRAM-DDR3
• 8 GB CF card,
runtime license 128 PT1)
• 50 GB SSD (High Endurance),
runtime license 128 PT1)
• 8 GB CF card,
runtime license 2048 PT1)
• 50 GB SSD (High Endurance),
runtime license 2048 PT1)

6ES7675-1DA31-7AY0

6ES7675-1DE31-7AY0

6ES7675-1DF31-7AY0

6ES7675-1DK41-7AY0
6ES7675-1DK41-2AY0
6ES7675-1DK41-7AV0
6ES7675-1DK41-2AV0

Accessories
6ES7675-1DF30-7AX0

CP 5603 Microbox Package
Package for using the PROFIBUS
CP 5603 in Microbox PCs;
comprising a CP 5603 module and
a Microbox expansion rack

6GK1560-3AU00

6ES7675-1DK40-.A.0

6GK1160-4AU00

6ES7675-1DK40-7AW0

CP 1604 Microbox Package
Package for the use of the
PROFINET CP 1604
in Microbox PCs;
consisting of CP 1604 card,
connection board, power supply
and Microbox PC expansion frame;
used via development kit
DK-16xx PN IO; NCM P
Portrait assembly kit
Interfaces to the front

6ES7648-1AA20-0YB0

6ES7675-1DK40-2AW0

Expansion components

From page 5/153

6ES7675-1DK40-7AX0
6ES7675-1DK40-2AX0

Number of process tags (PT) can be increased by means of PowerPacks.

5/106

IPC427C with WinCC RT
Professional, V11 SP2
Fan-free, 4 x USB 2.0 (500 mA),
1 x COM (RS 232),
24 V DC power supply
with On/Off switch,
2 x PROFINET (IE),
Windows Embedded Standard 7
SP1 pre-installed,
SIMATIC WinCC Runtime
Professional V11 SP2 pre-installed

Client and stand-alone station
configurations
• Core2 Solo processor 1.2 GHz,
2 GB SDRAM DDR3,
8 GB CF card,
runtime license 128 PT 1)
• Core2 Solo processor 1.2 GHz,
PROFIBUS DP,
2 GB SDRAM DDR3,
8 GB CF card,
runtime license 128 PT 1)

("Built to order" with max. delivery
time of 14 working days; only repairs
are possible for hardware)

Client configurations
Processor Celeron M 1.2 GHz,
1 GB SDRAM-DDR3,
4 GB CF Card,
runtime license 128 PT

Order No.
Bundles with WinCC RT
Professional (TIA Portal)

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
Embedded bundles/Software packages
SIMATIC IPC427C bundles

■ More information
Delivery

Replacement units

Production and delivery of the devices will typically be
completed within 13 business days after receipt of order. The
hardware and mass memory with the complete, pre-installed,
ready-to-use software are supplied fully assembled.

For the preferred versions, repaired replacement devices are
available extremely quickly ex stock. Preferred versions offer the
following options:
• All processor versions with PROFINET(IE) or PROFIBUS
option
• 2 GB RAM
• Exclusively for replaceable CompactFlash memory
(supplied without mass memory)
• All software configurations

Commissioning
Before the control or visualization application is complete,
simply perform the following steps:
• Optional: Install and setup additional hardware on the device
(e.g. an additional SIMATIC CP 5603 PROFIBUS interface)
• Optional: Installation and setup of other software on the device
• Transfer of the engineering projects from STEP 7 and/or
WinCC flexible
• Transfer of the supplied license keys for SIMATIC software
• Backup of the installed software and protection of the flashbased mass memory by switching on the Enhance Write filter

5

Siemens ST 80 / ST PC · 2013

5/107

© Siemens AG 2013

PC-based Automation
Embedded bundles/Software packages
SIMATIC IPC277D bundles

■ Overview

■ Technical specifications
See "PC-based Automation -> Panel PC -> SIMATIC IPC277D"

■ Ordering data
For selection and ordering data see
SIMATIC Panel PC -> SIMATIC IPC277D

■ More information
Delivery
Production and delivery of the devices will typically be
completed within 13 business days after receipt of order. The
hardware and mass memory with the complete, pre-installed,
ready-to-use software are supplied fully assembled.

5

SIMATIC IPC277D for implementing simple visualization and
control tasks
• High degree of flexibility when selecting rugged widescreen
fronts from 7" to 19" for more freely configurable display area
• High resolution, large viewing angle and up to 100%
dimmable backlighting for brilliant display with optimized
power consumption
• Absolutely maintenance-free due to the use of CompactFlash
and SSD as mass storage and fanless operation up to 50 °C
ambient temperature
• Maximum industrial functionality due to non-volatile retentive
memory for battery-free operation
• Ready-to-run embedded bundles with visualization or/and
control software
The following front installation versions are available:
• 7" Touch
• 9" Touch
• 12" Touch
• 15" Touch with front USB interface
• 19" Touch with front USB interface
• All fronts in widescreen design

5/108

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
Embedded bundles/Software packages
SIMATIC IPC477D bundles

■ Overview

■ Integration
Integrated interfaces:
• Ethernet
The integral PROFINET interfaces (10/100/1000 Mbit/s) can
be used for IT communication and for data exchange with
programmable controllers such as SIMATIC S7
(with software packages "SOFTNET S7 Basis").
• PROFIBUS onboard (option)
The isolated PROFIBUS interface (12 Mbit/s) can be used
for connecting distributed field devices or for coupling to
SIMATIC S7 (with software packages "SOFTNET for
PROFIBUS").
• Other interfaces
5 USB (Universal Serial Bus) interfaces and up to two serial
interfaces are available for connecting additional I/O devices.

■ Technical specifications
See "PC-based Automation -> Panel PC -> SIMATIC IPC477D"
SIMATIC IPC477D:
The powerful embedded Panel PC –
maintenance-free with versatile configuration
Ready-to-run, complete solutions (software is already installed
and preconfigured) for visualization and automation in
connection with WinCC RT Advanced and/or WinAC RTX.
• Embedded PC platform with extremely high industrial compatibility for demanding tasks in the field of PC-based automation
• Maintenance-free (no rotating components such as fan and
hard disk)
• Rugged construction: the PC is resistant to even the harshest
mechanical stress and is extremely reliable in operation
• Compact design
• Battery-independent retentive memory onboard
• High investment protection
• Fast integration capability
• Safety requirements up to SIL 3 in accordance with
IEC 61508/62061 or EN ISO 13849-1 up to PL e can be
implemented with WinAC RTX F

■ Ordering data
For selection and ordering data,
see SIMATIC Panel PC -> SIMATIC IPC477D

5

The following front versions are available:
• Built-in versions
- 12" TFT Touch
- 15" TFT Touch
- 19" TFT Touch
- 22" TFT Touch
- 15" TFT Touch/Key
• Current product versions of the pre-installed SIMATIC
software:
- SIMATIC WinCC RT Advanced V12
- SIMATIC WinAC RTX 2010 or SIMATIC WinAC RTX F 2010
- SIMATIC NET V8.2 (including SIMATIC SOFTNET S7 Basis
license)
- and the combinations of the software packageslisted above

Siemens ST 80 / ST PC · 2013

5/109

© Siemens AG 2013

PC-based Automation
Embedded bundles/Software packages
SIMATIC HMI IPC477C bundles

■ Overview
Embedded PC platform with extremely high industrial compatibility for demanding tasks in the field of PC-based automation.
• Rugged operation
- Operation without a hard disk, based on CompactFlash card
(CF Card) or solid-state drive and Windows Embedded
Standard
- Fan-free operation
- 128 KB of retentive data for WinAC RTX, also without
uninterruptible power supply (UPS)
• Flexibility of a PC-based automation environment
- Free memory space on CF Card can be used for other PC
applications
- Use of WinAC ODK with SIMATIC WinAC RTX or SIMATIC
WinAC RTX F (read-only for fail-safe program section)
- Connection option for USB devices, flat panel monitor or
screen
• High-performance service concept
- Replacement parts for preferred types available ex stock
• Safety requirements up to SIL 3 in accordance with
IEC 61508/62061 or EN ISO 13849-1 up to PL e can be
implemented with WinAC RTX F.
• Cost-effective versions with PROFINET, based on the
standard Ethernet interface
• Product versions of the pre-installed software:
- SIMATIC WinAC RTX 2010 or SIMATIC WinAC RTX F 2010
- SIMATIC WinCC flexible 2008 or WinCC RT Advanced
- and the combinations of the software packages above
- SIMATIC NET Edition 2008 or V8.x (depending on operating
system) as well as
- SIMATIC WInCC V7.0 SP2 or WinCC RT Professional as a
client / single station
The following display versions are available:
• Built-in versions
- 12" and 15" TFT Touch
- 12" and 15" TFT Key
- 19" Touch
• Support arm versions
- PRO 15" and 19" Touch
Fully-enclosed device to IP65 degree of protection for
mounting on a support arm/stand.

5

5/110

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
Embedded bundles/Software packages
SIMATIC HMI IPC477C bundles

■ Ordering data

Order No.

SIMATIC HMI IPC477C bundles

HMI bundles with
WinCC flexible 2008 or
WinCC RT Advanced bundles
HMI/RTX bundles
combining HMI and RTX
("Built to order" version, max. delivery time of 15 working days and
with identified repair, if not preferred
type)
6AV7883- 7 A 7 7 7 - 7 7 7 7

Embedded and fan-free
with fully enclosed IP65 enclosure
4 x USB (500 mA),
24 V DC power supply
with On/Off switch
SIMATIC HMI IPC477C

6AV7884- 7 A 7 7 7 - 7 7 7 7

SIMATIC HMI IPC477C
(continued)

RTX bundles with
SIMATIC WinAC RTX (F) 2010

SIMATIC HMI IPC477C PRO

Order No.

6AV7884- 7 A 7 7 7 - 7 7 7 7

Fan-free
5 x USB 2.0 (500 mA),
one of which on the front
1 x COM (RS232)
24 V DC power supply
with On/Off switch
Front panels
• 12" TFT Touch 1)
• 12" TFT Key
• 15" TFT Touch 1)
• 15" TFT Key
• 19" TFT Touch 1)
• 15" TFT Touch
(IP65 enclosure; PRO)
• 19" TFT Touch
(IP65 enclosure; PRO)

0
1
2
3
5
6
7

1)

Preferred versions with repaired replacement device from warehouse

2)

Only together from 2 GB main memory

3)

Only with IPC477C

Processors and fieldbus
• Celeron M 1.2 GHz,
2 x PROFINET (IE) 1)
• Celeron M 1.2 GHz,
2 x PROFINET (IE),
1 x PROFIBUS DP 12 1)
• Core2 Solo 1.2 GHz,
2 x PROFINET (IE) 1)
• Core2 Solo 1.2 GHz,
2 x PROFINET (IE),
1 x PROFIBUS DP 12 1)
• Core2 Solo 1.2 GHz,
1 x PROFINET (IE),
1 x PROFINET (3 ports) 1)
• Core2 Duo 1.2 GHz,
2 x PROFINET (IE) 1)
• Core2 Duo 1.2 GHz,
2 x PROFINET (IE),
1 x PROFIBUS DP 12 1)
• Core2 Duo 1.2 GHz,
1 x PROFINET (IE),
1 x PROFINET (3 ports) 1)

A
B

D
E

F

G
H

J

Main memory (DDR3 RAM),
1 database
• 1 GB
• 2 GB 1)
• 4 GB

1
2
3

Second mass storage
(installed, CF replaceable)
• None 1)
• CompactFlash 2 GB
(only with Windows Embedded
Standard 2009) 1)
• CompactFlash 4 GB 1)
• CompactFlash 8 GB 1)
• CompactFlash 16 GB 1)
• 50 GB SSD (High Endurance)
• 80 GB SSD (Standard) 3)

0
2

3
4
5
6
7

Siemens ST 80 / ST PC · 2013

5

5/111

© Siemens AG 2013

PC-based Automation
Embedded bundles/Software packages
SIMATIC HMI IPC477C bundles

■ Ordering data
SIMATIC HMI IPC477C
(continued)

Order No.

Mass storage
(installed, operating system
pre-installed, optionally with
SIMATIC software)
• CompactFlash 2 GB 1)
• CompactFlash 4 GB 1)
• CompactFlash 8 GB 1)
• CompactFlash 16 GB 1)
• 50 GB SSD (High Endurance)
• 80 GB SSD (Standard) 3)
Operating system
• Windows Embedded Standard
2009, pre-installed 1)
• Windows Embedded Standard 7
SP1, pre-installed 2)

5

Order No.

6AV7884- 7 A 7 7 7 - 7 7 7 7

Software packages,
only with CF 4 GB or higher 1)
• with operating system and RTX
pre-installed and configured
• with operating system and HMI
(incl. archives/recipes)
pre-installed and configured
- Number of tags 128 PT
- Number of tags 512 PT
- Number of tags 2048 PT
- Number of tags 4096 PT
• with operating system and
HMI/RTX (incl. archives/recipes)
pre-installed and configured
- Number of tags 128 PT
- Number of tags 512 PT
- Number of tags 2048 PT
- Number of tags 4096 PT
• with operating system and RTX F
pre-installed and configured
• with operating system and
HMI/RTX F (incl. archives/recipes)
pre-installed and configured
- Number of tags 128 PT
- Number of tags 512 PT
- Number of tags 2048 PT
- Number of tags 4096 PT

Bundles with WinCC RT
Professional (TIA Portal)
("Built to order" with max. delivery
time of 14 working days; only repairs
are possible for hardware)
SIMATIC HMI IPC477C

2
3
4
5
6
7
BA
E A

SIMATIC HMI IPC477C PRO

C
D
E
F

Front panel
• 15" TFT Touch
• 19" TFT Touch
• 15" TFT Touch PRO
• 19" TFT Touch PRO

K
L
M
N
P

6AV78846AV78846AV78836AV7883-

2
5
6
7

Client configurations
Celeron M processor 1.2 GHz,
1 GB DDR3 RAM,
4 GB CF card,
runtime license 128 PT

A 2

4

Y

Core2 Solo processor 1.2 GHz,
2 GB SDRAM-DDR3,
8 GB CF card,
runtime license 128 PT

D 2

4

Y

Core2 Solo processor 1.2 GHz,
PROFIBUS DP,
2 GB SDRAM-DDR3,
8 GB CF card,
runtime license 128 PT

E 2

4

Y

Client and stand-alone station
configurations
R
S
T
U
0
1

Stand-alone station
configurations
SIMATIC HMI IPC477C

6AV7884- 7 A H 3 0 - 7 E 7 0

SIMATIC HMI IPC477C PRO

6AV7883- 7 A H 3 0 - 7 E 7 0

Core2 Duo processor 1.2 GHz,
PROFIBUS DP, 4 GB SDRAM-DDR3
• 8 GB CF card
• 50 GB SSD (High Endurance)
• Runtime license 128 PT
• Runtime license 2048 PT
1)

Preferred versions with repaired replacement device from warehouse

2)

Only together from 2 GB main memory

3)

Only with IPC477C

4)

with WES 2009: SP2; with WES 7: SP3

Siemens ST 80 / ST PC · 2013

6AV7883- 7 A 7 7 0 - 7 E 7 0

Fanless, 4 x USB 2.0 (500 mA),
1 x USB 2.0 on front (except PRO),
1 x COM (RS232), 24 VDC power
supply with On/Off switch,
2 x PROFINET (IE), Windows
Embedded Standard 7 SP1
pre-installed,
SIMATIC WinCC Professional V11
SP2

B

• HMI RT: WinCC flexible 2008 4)
or w/o HMI software
• HMI RT: WinCC Advanced V11
SP2 (TIA Portal), only with WES7
SP1 and 2 GB RAM

5/112

6AV7884- 7 A 7 7 0 - 7 E 7 0

Fanless
4 x USB 2.0 at rear,
1 x USB 2.0 at front,
1 x COM (RS232),
2 x 10/100/1000 Mbit/s Ethernet
(RJ45);
software pre-installed on CF/SSD:
Windows Embedded Standard 7
SP1,
SIMATIC WinCC Professional V11
SP2

4
6
Y
V

© Siemens AG 2013

PC-based Automation
Embedded bundles/Software packages
SIMATIC HMI IPC477C bundles

■ Ordering data

Order No.

Order No.

Bundles with WinCC V7.0 SP2
incl. Update 1
("Built to order" with max. delivery
time of 14 working days; only repairs
are possible for hardware)
SIMATIC HMI IPC477C

Accessories

6AV7884- 7 A 7 7 0 - 7 B 7 0

Fanless
4 x USB 2.0 at rear, 1 x USB 2.0
at front, 1 x COM (RS232),
2 x 10/100/1000 Mbit/s Ethernet
(RJ45);
software pre-installed on CF/SSD:
Windows Embedded Standard,
SIMATIC WinCC V7.0 SP1
SIMATIC HMI IPC477C PRO

6AV7883- 7 A 7 7 0 - 7 B 7 0

Fanless, 5 x USB 2.0 (500 mA),
1 x USB 2.0 at front (not on PRO),
1 x COM (RS232), 24 V DC power
supply with On/Off switch,
2 x PROFINET (IE), Windows
Embedded 2009 pre-installed,
SIMATIC WinCC V7.0 SP2 incl.
Update 1 Runtime pre-installed
Front panel
• 15" TFT Touch
• 19" TFT Touch
• 15" TFT Touch PRO
• 19" TFT Touch PRO

6AV78846AV78846AV78836AV7883-

Protective film
for Panel PCs 477/577/677
For protecting the touch screen
against dirt/scratches
• for 12" Touch
• for 15" Touch (not for PRO)
• for 19" Touch

6AV7671-2BA00-0AA0
6AV7671-4BA00-0AA0
6AV7672-1CE00-0AA0

Labeling membranes
for Panel PCs 477/577/677
For labeling soft keys and function
keys, blank, supplied in sets of 10

6AV7672-0DA00-0AA0

Touch pen
Captive pen for operation of the
touch devices; holder can be
mounted on the control cabinet or
direct on the PRO unit

6AV7672-1JB00-0AA0

Expansion components

From page 5/153

2
5
6
7

Client configurations
Celeron M processor 1.2 GHz,
1 GB DDR3 RAM, 4 GB CF card,
runtime license 128 PT

A 1

3

X

• Core2 Solo processor 1.2 GHz,
2 GB SDRAM-DDR3, 8 GB CF card,
runtime license 128 PT

D 2

4

X

• Core2 Solo processor 1.2 GHz,
PROFIBUS DP,
2 GB SDRAM-DDR3,
8 GB CF card,
runtime license 128 PT

E 2

4

X

Client and stand-alone station
configurations

5

Stand-alone station
configurations
SIMATIC HMI IPC477C

6AV7884- 7 A H 3 0 - 7 B 7 0

SIMATIC HMI IPC477C PRO

6AV7883- 7 A H 3 0 - 7 B 7 0

Core2 Duo processor 1.2 GHz,
PROFIBUS DP, 4 GB SDRAM-DDR3
• 8 GB CF card
• 50 GB SSD (High Endurance)
• Runtime license 128 PT
• Runtime license 2048 PT

4
6
X
W

Note:

Please be sure to note:

Other ready-to-use SIMATIC HMI IPC477Cs can be found in the
Panel PC chapter under HMI IPC477C.

The HMI IPC477C is delivered as standard with an inserted
CF card. The licenses are located on the supplied USB flash
drive.

Siemens ST 80 / ST PC · 2013

5/113

© Siemens AG 2013

PC-based Automation
Embedded bundles/Software packages
Software packages for SIMATIC IPC and S7-mEC

■ Overview
HMI complete systems

SIMATIC IPC and S7-mEC with SIMATIC WinCC flexible
• SIMATIC IPC packages with WinCC flexible are an innovative
solution for simple visualization tasks directly at the machine
in the field of HMI.
• This package can only be supplied if a SIMATIC IPC or
S7-mEC (same quantity) is ordered together with the
WinCC flexible Runtime software. It cannot be ordered
subsequently.
• In combination with the embedded SIMATIC IPC
(HMI IPC477C (PRO) and IPC427C) and the embedded
controller S7-mEC, there are turn-key solutions (bundles),
i.e. the runtime software is already preinstalled.
SIMATIC IPC with SIMATIC WinCC (TIA Portal)
• The SIMATIC IPC packages with WinCC make it easy to order
all the components required for an HMI solution on the basis
of a Panel PC.
• This package can only be supplied if a SIMATIC IPC (same
quantity) is ordered together with the WinCC RT Advanced or
WinCC RT Professional software. It cannot be ordered subsequently.
• In combination with the embedded SIMATIC IPC (IPC277D /
HMI IPC477C (PRO) / IPC477D and IPC227D / IPC427C /
IPC427D) there are turn-key solutions (bundles) available, i.e.
the runtime software is already preinstalled.
SIMATIC IPC with SIMATIC WinAC RTX (F)
• The SIMATIC IPC packages with WinAC RTX (F) make it easy
to order all the components required for a control solution on
the basis of an industrial PC.
• This package can only be supplied if a SIMATIC Industrial PC
(same quantity) is ordered together with the WinAC RTX
Runtime software. It cannot be ordered subsequently.
• In combination with the embedded SIMATIC IPC (IPC277D /
HMI IPC477C (PRO) / IPC477D and IPC227D / IPC427C /
IPC427D) and the S7-mEC embedded controller, there are
turn-key solutions (bundles) available, i.e. the runtime
software is already preinstalled.

5

5/114

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
Embedded bundles/Software packages
Software packages for SIMATIC IPC and S7-mEC

■ Ordering data

Order No.

SIMATIC WinCC flexible
package 1) 3)
(incl. archives and recipes)

6AV6623- 2 7 A 0 0 - 0 A A 0

WinCC flexible 2008 Runtime
• 128 PowerTags
• 512 PowerTags
• 2048 PowerTags
• 4096 PowerTags
SIMATIC WinCC package 2)

B
D
F
G
6AV6382- 2 7 A 0 7 - 2 A X 0

WinCC V7.2 Runtime 2)
• 128 PowerTags
• 256 Power Tags
• 1 024 PowerTags
• 8 192 PowerTags
• 65 536 PowerTags

C
D
E
H
F

SIMATIC WinCC package 2)
WinCC V7.0 SP3 Runtime
• 128 PowerTags
• 512 PowerTags
• 2 048 PowerTags
• 8 192 PowerTags
• 65 536 PowerTags

Order No.

6AV6382- 2 7 A 0 7 - 0 A X 0

2)

C
D
E
H
F

1)

Only if ordered together with a SIMATIC IPC, SIMATIC Panel PC Ex,
or S7-mEC

2)

Only if ordered together with a SIMATIC IPC

3)

The current version will always be supplied

SIMATIC WinCC (TIA Portal)
WinCC Runtime Advanced
Package 1)3)

6AV2114- 2 7 A 0 0 - 0 A A 0

Incl. Recipes + Logging
• 128 PowerTags
• 512 PowerTags
• 2048 PowerTags
• 4096 PowerTags
SIMATIC WinCC Runtime
Professional Package 2)3)
• 128 PowerTags
• 512 PowerTags
• 2048 PowerTags
• 4096 PowerTags
• 8192 PowerTags
• 65536 PowerTags

B
D
F
H
6AV2115- 2 7 A 0 0 - 0 A A 0
B
D
F
H
K
M

1)

Only if ordered together with a SIMATIC IPC, SIMATIC Panel PC Ex,
or S7-mEC

2)

Only if ordered together with a SIMATIC IPC

3)

The current version will always be supplied

SIMATIC WinAC RTX (F) package
• SIMATIC WinAC RTX 1) 2)
• SIMATIC WinAC RTX F 1) 2)

Ready-to-use SIMATIC HMI
IPC477C with WinCC
("Built to order" with max. delivery
time of 14 working days; only repairs
are possible for hardware)
6AV7884- 7 A 7 7 0 - 7 B 7 0

SIMATIC HMI IPC477C
with WinCC V7.0
Fanless,
5 x USB2.0 (500 mA),
1 of which at front,
1 x COM (RS232),
power supply 24 V DC
with On/Off switch,
2 x PROFINET (IE),
2 GB main memory
(DDR3-SDRAM),
CompactFlash Card 8 GB;
Windows Embedded 2009
preinstalled;
SIMATIC WinCC V7.0 SP2 Runtime
preinstalled
Client configurations

7AA 1 0 - 4 BX 0

Celeron M processor, 1.2 GHz,
1 GB SDRAM-DDR3, 8 GB CF card,
runtime license 128 PT
• 15" Touch
• 19" Touch

3
5

Client and stand-alone station
configurations
Core2 Solo processor 1.2 GHz,
2 GB SDRAM-DDR3, 8 GB CF card,
runtime license 128 PT
• 15" Touch
• 19" Touch

7AE 2 0 - 4 BX 0

3
5

7AH 3 0 -7B7 0

Stand-alone station
configurations
Processor Core2 Duo 1.2 GHz,
4 GB SDRAM-DDR3
• 15" Touch
• 19" Touch
• 8 GB CF card
• 50 GB SSD
• Runtime license 128 PT
• Runtime license 2048 PT

5

3
5

7
7
7
7

A
A
A
A

H
H
H
H

3
3
3
3

0
0
0
0

-

4
6

7BX 0
7 BW 0

6ES7671-0RC08-6YA0
6ES7671-1RC08-6YA0

1)

Only if ordered together with a SIMATIC IPC

2)

The current version will always be supplied

Note:
For ordering data for Panel PCs and accessories,
see configurators in "SIMATIC Panel PCs".

Siemens ST 80 / ST PC · 2013

5/115

© Siemens AG 2013

PC-based Automation
Embedded bundles/Software packages
Software packages for SIMATIC IPC and S7-mEC

■ Ordering data

■ More information

Order No.

Further information can be found in the Internet at:

HMI IPC477C / HMI IPC477C PRO
with WinCC RT Professional
(TIA Portal)

http://www.automation.siemens.com/simatic-hmi

("Built to order" version, max. delivery time of 15 working days and with
identified repair, if not preferred
type)
SIMATIC HMI IPC477C
with WinCC RT Professional
(TIA Portal)

6AV788 4 - 7 A 7 7 0 - 7 E 7 0

SIMATIC HMI IPC477C PRO
with WinCC RT Professional
(TIA Portal)

6AV788 3 - 7 A 7 7 0 - 7 E 7 0

Fan-free
5 x USB 2.0 (500 mA),
one of which on the front
1 x COM (RS232)
24 V DC power supply with
On/Off switch, 2 x PROFINET (IE),
2 GB main memory
(DDR3-SDRAM),
CompactFlash Card 8 GB,
Windows Embedded Standard 7
SP1 pre-installed,
SIMATIC WinCC RT Professional
V11 SP2 pre-installed
Front panels
• 15" Touch
• 15" Touch PRO
• 19" Touch
• 19" Touch PRO

4
3
4
3

Client configurations

7-7AA 2 0 - 4 E Y 0

3
6
5
7

Core2 Solo processor 1.2 GHz,
2 GB SDRAM-DDR3, 8 GB CF card,
runtime license 128 PT

5

Client and stand-alone station
configurations

4 - 7 A A 2 0 - 4 E Y 0

Core2 Solo processor 1.2 GHz,
2 GB SDRAM-DDR3, 8 GB CF card,
runtime license 128 PT
Stand-alone station
configurations
Processor Core2 Duo 1.2 GHz,
4 GB SDRAM-DDR3
• 8 GB CF card
• 50 GByte SSDe
• Runtime license 128 PT
• Runtime license 2048 PT

4 - 7 A H 3 0 - 7 E 7 0

7-7AH 3 0 - 4 E7 0
6

7-7AH 3 0 -7 E Y 0
V

Note:
Other ready-to-use SIMATIC HMI IPC477Cs can be found in the
Panel PC chapter under HMI IPC477C.

5/116

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
Industrial monitors and thin clients
SIMATIC Industrial Flat Panel MT

■ Overview
SIMATIC IFP1900 MT Flat Panel Monitor – industrial monitors
with innovative multi-touch operation and brilliant display for the
next generation of operating concepts.
• Installation:
- Equally suited to installation in machines, control cabinets,
consoles, and gantries or in 19" racks
• Operator input options:
- Innovative projected capacitive touch technology (PCT)
- Optimized touch technology for industrial requirements with
multi-touch operation
- High protection against incorrect operation thanks to
detection and filtering out of ball of hand, drops of water, and
cleaning operations

■ Technical specifications
6AV7466-7TB01-0AA0

6AV7466-7TB01-0AA0

IFP1900 MT
Display
Screen diagonal

18.5 in

Screen diagonal (cm)

47 cm

Display width

409.8 mm

Display height

230.4 mm

Viewing angle

170° x 170°

Type

TFT widescreen display,
LED backlighting

On Screen Display (OSD)
configuration

No, can be set with the software

Number of colors (bit levels)

24 bit

Resolution (pixels)
• Resolution (WxH in pixel)

1366 x 768

General features
• Detachable from computer unit

30 m

Backlighting
• Backlighting (type)
• MTBF backlighting
(up to 50%, at 25 °C)
• Dimmable backlight

LED
50 000 h; At 25°C
Yes; 0-100 %

IFP1900 MT
Control elements
Function keys

No

Mouse/cursor control
• external mouse

USB

Touch operation
• Touch keyboard

Yes

Installation type/mounting
Built-in unit
• Permissible angle to the vertical
backward (console)
• Permissible angle to the vertical
forward (ceiling mounting)

Yes
35°

5

35°

Supply voltage
Type of actuation
• AC
• DC

AC, DC
Yes
Yes

Rated voltage (AC)

0V

Rated voltage (DC)

24 V

permissible range, lower limit (DC)

19.2 V

permissible range, upper limit (DC)

28.8 V

permissible range, lower limit (AC)

85 V

permissible range, upper limit (AC)

265 V

Siemens ST 80 / ST PC · 2013

5/117

© Siemens AG 2013

PC-based Automation
Industrial monitors and thin clients
SIMATIC Industrial Flat Panel MT

■ Technical specifications (continued)
6AV7466-7TB01-0AA0

6AV7466-7TB01-0AA0

IFP1900 MT
Power losses
Power loss AC
• Typical
• Maximum

40 W
60 W

Power loss DC
• Typical
• Maximum

40 W
65 W

Interfaces
USB on the rear

2

Video interfaces
• DVI-D
• Display port

Yes
Yes; Display port V1.1

Touch interfaces
• USB

Yes

Degree and class of protection
IP65 at front

Yes

Enclosure Type 4 at the front

Yes

NEMA4 at the front

No

NEMA4X at the front
IP20 rear
Standards, approvals, certificates
CE

5

0 °C

Max. ambient temperature

45 °C

Storage/transport temperature
• Min.
• max.

-20 °C
60 °C

Relative humidity
• Relative humidity during operation

95 %

Connection method
Connector for cooling devices

Yes

Mechanics/material
Type of housing (front)
• Aluminum

Aluminum
Yes

Dimensions
Width of the housing front

483 mm

Height of housing front

337 mm

No

Mounting cutout (W x H x D)
• Mounting cutout, width
• Mounting cutout, height

465 mm
319 mm

Yes

Depth/installation dimension

62.5 mm

Yes

Weight
Weight without packaging

6.34 kg

Weight incl. packaging

9.52 kg

UL approval
• UL 508

Yes

cULus

Yes

EN 50081-1

Yes

EN 50081-2

Yes

EN 50082-1

Yes

EN 50082-2

Yes

5/118

IFP1900 MT
Ambient conditions
Min. ambient temperature

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
Industrial monitors and thin clients
SIMATIC Industrial Flat Panel MT
Order No.
6AV7466-7TB01-0AA0

■ Dimensional drawings
All dimensions in mm. For mounting cut-out see technical
specifications.

H
D

W

6.5

W+1

G_ST80_XX_00522

SIMATIC IFP1900 MT
Flat Panel, 19" display (16:9),
operation using multitouch gestures,
extended version up to 30 m,
1366 x 768 pixels,
for 24 V DC and 100-240 V AC,
display port/DVI interface,
incl. 1.8 m DVI/USB cable

H+1

■ Ordering data

Mounting dimensions
Industrial
Flat Panel MT

IFP1900

Front dimensions
in mm

Mounting Cutout, in mm

W

H

W+1

H+1

D

483

337

465

319

93

5

Siemens ST 80 / ST PC · 2013

5/119

© Siemens AG 2013

PC-based Automation
Industrial monitors and thin clients
SIMATIC Industrial Flat Panel

■ Overview
The Industrial Flat Panels are rugged industry-standard LCD
monitors in a wide screen design.
• Installation:
- Equally suited for installation in the machine, in control
cabinets, in consoles, to gantries, or in 19" racks.
• Type of operator control:
- Simple display devices without operator functionality
- Optional devices with touch control
- Rear-mounted connection of I/O devices (optional).

■ Technical specifications

5

6AV7863-2AA00-0AA0
IFP1500

6AV7863-2AB10-0AA0
IFP1500

6AV7863-2TA00-0AA0
IFP1500

6AV7863-2TB10-0AA0
IFP1500

General information
Short designation

Flat Panel 15" display

Flat Panel 15" display ext.

Flat Panel 15" Touch

Flat Panel 15" Touch ext.

Display
Screen diagonal

15.4 in

15.4 in

15.4 in

15.4 in

Screen diagonal (cm)

40 cm

40 cm

40 cm

40 cm

Display width

331.2 mm

331.2 mm

331.2 mm

331.2 mm

Display height

207 mm

207 mm

207 mm

207 mm

Viewing angle

170° x 170°

170° x 170°

170° x 170°

170° x 170°

Type

TFT widescreen display,
LED backlighting

TFT widescreen display,
LED backlighting

TFT widescreen display,
LED backlighting

TFT widescreen display,
LED backlighting

On Screen Display (OSD)
configuration

No, can be set with the
software

No, can be set with the
software

No, can be set with the
software

No, can be set with the
software

Number of colors (bit levels)

24 bit

24 bit

24 bit

24 bit

Number of colors

16 777 200

16 777 200

16 777 200

16 777 200

Resolution (pixels)
• Horizontal image resolution
• Vertical image resolution
• Pixel size, horizontal
• Pixel size, vertical

1 280
800
0.259 mm
0.259 mm

1 280
800
0.259 mm
0.259 mm

1 280
800
0.259 mm
0.259 mm

1 280
800
0.259 mm
0.259 mm

Yes

Yes

5m
400 cd/m² / 1000:1
400 cd/m²

30 m
400 cd/m² / 1000:1
400 cd/m²

5m
400 cd/m² / 1000:1
400 cd/m²

5m
400 cd/m² / 1000:1
400 cd/m²

LED
50 000 h; At 25°C

LED
50 000 h; At 25°C

LED
50 000 h; At 25°C

LED
50 000 h; At 25°C

Yes; 0-100 %

Yes; 0-100 %

Yes; 0-100 %

Yes; 0-100 %

General features
• Non-reflective and tempered mineral
glass screen
• Detachable from computer unit
• Brightness/contrast
• Brightness, max.
Backlighting
• Backlighting (type)
• MTBF backlighting
(up to 50%, at 25 °C)
• Dimmable backlight

5/120

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
Industrial monitors and thin clients
SIMATIC Industrial Flat Panel

■ Technical specifications (continued)
Control elements
Function keys

6AV7863-2AA00-0AA0
IFP1500

6AV7863-2AB10-0AA0
IFP1500

6AV7863-2TA00-0AA0
IFP1500

6AV7863-2TB10-0AA0
IFP1500

No

No

No

No

Mouse/cursor control
• external mouse

USB

Keyboard fonts
• Alphanumeric and numeric block

Yes

Touch operation
• Touch keyboard
Installation type/mounting
Built-in unit
• Permissible angle to the vertical
backward (console)
• Permissible angle to the vertical
forward (ceiling mounting)
Supply voltage
Type of actuation
• AC
• DC

USB

Yes

Yes

Yes
35°

Yes
35°

Yes
35°

Yes
35°

35°

35°

35°

35°

DC

DC
Yes
Yes

DC
Yes

DC
Yes
Yes

Yes

100 V; Up to 240V 50/60Hz

Rated voltage (AC)
Rated voltage (DC)

24 V

24 V

24 V

24 V

permissible range, lower limit (DC)

19.2 V

19.2 V

19.2 V

19.2 V

permissible range, upper limit (DC)

28.8 V

28.8 V

28.8 V

28.8 V

permissible range, lower limit (AC)

90 V

90 V

permissible range, upper limit (AC)

264 V

264 V

Power losses
Power loss AC
• Typical
• Maximum

40 W
60 W

40 W
60 W

Power loss DC
• Typical
• Maximum

40 W
65 W

Interfaces
USB on the rear

40 W
65 W

40 W
65 W

5

40 W
65 W

2

2

Video interfaces
• DVI-D
• Display port

Yes
Yes; Display port V1.1

Yes
Yes; Display port V1.1

Yes
Yes; Display port V1.1

Yes
Yes; Display port V1.1

Touch interfaces
• USB

No

No

Yes

Yes

Degree and class of protection
IP65 at front

Yes

Yes

Yes

Yes

Enclosure Type 4 at the front

Yes

Yes

Yes

Yes

NEMA4 at the front

No

No

No

No

NEMA4X at the front

No

No

No

No

IP20 rear

Yes

Yes

Yes

Yes

Siemens ST 80 / ST PC · 2013

5/121

© Siemens AG 2013

PC-based Automation
Industrial monitors and thin clients
SIMATIC Industrial Flat Panel

■ Technical specifications (continued)
6AV7863-2AA00-0AA0
IFP1500

6AV7863-2AB10-0AA0
IFP1500

6AV7863-2TA00-0AA0
IFP1500

6AV7863-2TB10-0AA0
IFP1500

Standards, approvals, certificates
CE

Yes

Yes

Yes

Yes

KC approval

Yes

Yes

Yes

Yes

cULus

Yes; Corresponds to
UL 508

Yes; Corresponds to
UL 508

Yes; Corresponds to
UL 508

Yes; Corresponds to
UL 508

C-TICK

Yes

Yes

Yes

Yes

GL

Yes; Available soon

Yes; Available soon

Yes; Available soon

Yes; Available soon

ABS

Yes; Available soon

Yes; Available soon

Yes; Available soon

Yes; Available soon

BV

Yes; Available soon

Yes; Available soon

Yes; Available soon

Yes; Available soon

DNV

Yes; Available soon

Yes; Available soon

Yes; Available soon

Yes; Available soon

LRS

Yes; Available soon

Yes; Available soon

Yes; Available soon

Yes; Available soon

Class NK

Yes; Available soon

Yes; Available soon

Yes; Available soon

Yes; Available soon

Use in hazardous areas
• ATEX Zone 22
• FM Class I Division 2

Yes; Available soon
Yes; Available soon

Yes; Available soon
Yes; Available soon

Yes; Available soon
Yes; Available soon

Yes; Available soon
Yes; Available soon

Ambient conditions
Min. ambient temperature

0 °C

0 °C

0 °C

0 °C

50 °C; Vertical installation
(horizontal)

50 °C; Vertical installation
(horizontal)

50 °C; Vertical installation
(horizontal)

50 °C; Vertical installation
(horizontal)

Storage/transport temperature
• Min.
• max.

-20 °C
60 °C

-20 °C
60 °C

-20 °C
60 °C

-20 °C
60 °C

Relative humidity
• Relative humidity during operation

95 %; Non-condensing

95 %; Non-condensing

95 %; Non-condensing

95 %; Non-condensing

1g
1g

1g
1g

1g
1g

1g
1g

15 g
15 g

15 g
15 g

15 g
15 g

15 g
15 g

Max. ambient temperature

Vibrations
• Vibration load in operation
• Vibration load during
transport/storage

5

Shock testing
• Shock loading in operation
• Shock load during transport/storage
Connection method
Connector for cooling devices

Yes

Mechanics/material
Type of housing (front)
• Aluminum

Aluminum
Yes

Aluminum
Yes

Aluminum
Yes

Aluminum
Yes

Dimensions
Width of the housing front

415 mm

415 mm

415 mm

415 mm

Height of housing front

310 mm

310 mm

310 mm

310 mm

Depth/installation dimension

62.5 mm

62.5 mm

62.5 mm

62.5 mm

Mounting cutout, width

396 mm; Tolerance: +1 mm

396 mm; Tolerance: +1 mm

396 mm; Tolerance: +1 mm

396 mm; Tolerance: +1 mm

Mounting cutout, height

291 mm; Tolerance: +1 mm

291 mm; Tolerance: +1 mm

291 mm; Tolerance: +1 mm

291 mm; Tolerance: +1 mm

Weight
Weight without packaging

3.9 kg

3.9 kg

3.9 kg

3.9 kg

Weight incl. packaging

5 kg

5 kg

5 kg

5 kg

5/122

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
Industrial monitors and thin clients
SIMATIC Industrial Flat Panel

■ Technical specifications (continued)
6AV7 863-3AA00-0AA0
IFP1900

6AV7 863-3AB10-0AA0
IFP1900

6AV7 863-3TA00-0AA0
IFP1900

6AV7 863-3TB10-0AA0
IFP1900

General information
Short designation

Flat Panel 19" display

Flat Panel 19" display ext.

Flat Panel 19" Touch

Flat Panel 19" Touch ext.

Display
Screen diagonal

18.5 in

18.5 in

18.5 in

18.5 in

Screen diagonal (cm)

47 cm

47 cm

47 cm

47 cm

Display width

409.8 mm

409.8 mm

409.8 mm

409.8 mm

Display height

230.4 mm

230.4 mm

230.4 mm

230.4 mm

Type

TFT

TFT

TFT

TFT

On Screen Display (OSD)
configuration

No, can be set
with the software

No, can be set
with the software

No, can be set
with the software

No, can be set
with the software

Number of colors (bit levels)

24 bit

24 bit

24 bit

24 bit

Resolution (pixels)
• Resolution (WxH in pixel)
• Pixel size, horizontal
• Pixel size, vertical

1366 x 768
0.3 mm
0.3 mm

1366 x 768
0.3 mm
0.3 mm

1366 x 768
0.3 mm
0.3 mm

1366 x 768
0.3 mm
0.3 mm

Yes

Yes

5m

30 m

5m

30 m

LED
50 000 h; At 25°C

LED
50 000 h; At 25°C

LED
50 000 h; At 25°C

LED
50 000 h; At 25°C

Yes; 0-100 %

Yes; 0-100 %

Yes; 0-100 %

Yes; 0-100 %

No

No

No

No

General features
• Non-reflective and tempered mineral
glass screen
• Detachable from computer unit
Backlighting
• Backlighting (type)
• MTBF backlighting
(up to 50%, at 25 °C)
• Dimmable backlight
Control elements
Function keys
Mouse/cursor control
• external mouse

USB

Touch operation
• Touch keyboard
Installation type/mounting
Built-in unit
• Permissible angle to the vertical
backward (console)
• Permissible angle to the vertical
forward (ceiling mounting)

USB
Yes

Yes

Yes
35°

Yes
35°

Yes
35°

Yes
35°

35°

35°

35°

35°

Siemens ST 80 / ST PC · 2013

5

5/123

© Siemens AG 2013

PC-based Automation
Industrial monitors and thin clients
SIMATIC Industrial Flat Panel

■ Technical specifications (continued)
Supply voltage
Type of actuation
• AC
• DC

6AV7 863-3AA00-0AA0
IFP1900

6AV7 863-3AB10-0AA0
IFP1900

6AV7 863-3TA00-0AA0
IFP1900

6AV7 863-3TB10-0AA0
IFP1900

DC

DC
Yes
Yes

DC

DC
Yes
Yes

Yes

100 V; Up to 240V 50/60Hz

Rated voltage (DC)

24 V

24 V

24 V

24 V

permissible range, lower limit (DC)

19.2 V

19.2 V

19.2 V

19.2 V

permissible range, upper limit (DC)

28.8 V

28.8 V

28.8 V

28.8 V

permissible range, lower limit (AC)

90 V

90 V

permissible range, upper limit (AC)

264 V

264 V

Power losses
Power loss AC
• Typical
• Maximum

40 W
60 W

40 W
60 W

Power loss DC
• Typical
• Maximum

40 W
65 W

Interfaces
USB on the rear

5

Yes

100 V; Up to 240V 50/60Hz

Rated voltage (AC)

40 W
65 W

40 W
65 W

2

40 W
65 W
2

Video interfaces
• DVI-D
• Display port

Yes
Yes; Display port V1.1

Yes
Yes; Display port V1.1

Yes
Yes; Display port V1.1

Yes
Yes; Display port V1.1

Touch interfaces
• USB

No

No

Yes

Yes

Degree and class of protection
IP65 at front

Yes

Yes

Yes

Yes

Enclosure Type 4 at the front

Yes

Yes

Yes

Yes

NEMA4 at the front

No

No

No

No

NEMA4X at the front

No

No

No

No

IP20 rear

Yes

Yes

Yes

Yes

Standards, approvals, certificates
CE

Yes

Yes

Yes

Yes

KC approval

Yes

Yes

Yes

Yes

cULus

Yes; Corresponds to UL
508

Yes; Corresponds to UL
508

Yes; Corresponds to UL
508

Yes; Corresponds to UL
508

C-TICK

Yes

Yes

Yes

Yes

GL

Yes; Available soon

Yes; Available soon

Yes; Available soon

Yes; Available soon

ABS

Yes; Available soon

Yes; Available soon

Yes; Available soon

Yes; Available soon

BV

Yes; Available soon

Yes; Available soon

Yes; Available soon

Yes; Available soon

DNV

Yes; Available soon

Yes; Available soon

Yes; Available soon

Yes; Available soon

LRS

Yes; Available soon

Yes; Available soon

Yes; Available soon

Yes; Available soon

Class NK

Yes; Available soon

Yes; Available soon

Yes; Available soon

Yes; Available soon

Use in hazardous areas
• ATEX Zone 22
• FM Class I Division 2

Yes; Available soon
Yes; Available soon

Yes; Available soon
Yes; Available soon

Yes; Available soon
Yes; Available soon

Yes; Available soon
Yes; Available soon

5/124

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
Industrial monitors and thin clients
SIMATIC Industrial Flat Panel

■ Technical specifications (continued)
6AV7 863-3AA00-0AA0
IFP1900

6AV7 863-3AB10-0AA0
IFP1900

6AV7 863-3TA00-0AA0
IFP1900

6AV7 863-3TB10-0AA0
IFP1900

0 °C

0 °C

0 °C

0 °C

45 °C; Vertical installation
(horizontal)

45 °C; Vertical installation
(horizontal)

45 °C; Vertical installation
(horizontal)

45 °C; Vertical installation
(horizontal)

Storage/transport temperature
• Min.
• max.

-20 °C
60 °C

-20 °C
60 °C

-20 °C
60 °C

-20 °C
60 °C

Relative humidity
• Relative humidity during operation

95 %; Non-condensing

95 %; Non-condensing

95 %; Non-condensing

95 %; Non-condensing

1g
1g

1g
1g

1g
1g

1g
1g

15 g
15 g

15 g
15 g

15 g
15 g

15 g
15 g

Ambient conditions
Min. ambient temperature
Max. ambient temperature

Vibrations
• Vibration load in operation
• Vibration load during transport/storage
Shock testing
• Shock loading in operation
• Shock load during transport/storage
Connection method
Connector for cooling devices

Yes

Yes

Mechanics/material
Type of housing (front)
• Aluminum

Aluminum
Yes

Aluminum
Yes

Aluminum
Yes

Aluminum
Yes

Dimensions
Width of the housing front

483 mm

483 mm

483 mm

483 mm

Height of housing front

337 mm

337 mm

337 mm

337 mm

Mounting cutout (W x H x D)
• Mounting cutout, width
• Mounting cutout, height

465 mm; Tolerance: +1 mm
319 mm; Tolerance: +1 mm

465 mm; Tolerance: +1 mm
319 mm; Tolerance: +1 mm

465 mm; Tolerance: +1 mm
319 mm; Tolerance: +1 mm

465 mm; Tolerance: +1 mm
319 mm; Tolerance: +1 mm

Depth/installation dimension

62.5 mm

62.5 mm

62.5 mm

62.5 mm

Weight
Weight without packaging

5.5 kg

5.5 kg

5.5 kg

5.5 kg

Weight incl. packaging

6.5 kg

6.5 kg

6.5 kg

6.5 kg

Siemens ST 80 / ST PC · 2013

5

5/125

© Siemens AG 2013

PC-based Automation
Industrial monitors and thin clients
SIMATIC Industrial Flat Panel

■ Technical specifications (continued)
6AV7 863-4AA00-0AA0
IFP2200

6AV7 863-4AB10-0AA0
IFP2200

6AV7 863-4TA00-0AA0
IFP2200

6AV7 863-4TB10-0AA0
IFP2200

General information
Short designation

Flat Panel 22" display

Flat Panel 22" display ext.

Flat Panel 19" Touch

Flat Panel 22" Touch ext.

Display
Screen diagonal

21.5 in

21.5 in

21.5 in

21.5 in

Screen diagonal (cm)

56 cm

56 cm

56 cm

56 cm

Display width

476 mm

476 mm

476 mm

476 mm

Display height

268 mm

268 mm

268 mm

268 mm

Viewing angle

170° x 170°

170° x 170°

170° x 170°

170° x 170°

Type

TFT

TFT

TFT

TFT

On Screen Display (OSD)
configuration

No, can be set
with the software

No, can be set
with the software

No, can be set
with the software

No, can be set
with the software

Number of colors (bit levels)

24 bit

24 bit

24 bit

24 bit

Resolution (pixels)
• Resolution (WxH in pixel)
• Pixel size, horizontal
• Pixel size, vertical

1920 x 1080
0.2475 mm
0.2475 mm

1920 x 1080
0.2475 mm
0.2475 mm

1920 x 1080
0.2475 mm
0.2475 mm

1920 x 1080
0.2475 mm
0.2475 mm

Yes

Yes

5m
250 cd/m² / 1000:1

30 m
250 cd/m² / 1000:1

5m
250 cd/m² / 1000:1

30 m
250 cd/m² / 1000:1

LED
50 000 h; At 25°C

LED
50 000 h; At 25°C

LED
50 000 h; At 25°C

LED
50 000 h; At 25°C

Yes; 0-100 %

Yes; 0-100 %

Yes; 0-100 %

Yes; 0-100 %

No

No

No

No

General features
• Non-reflective and tempered
mineral glass screen
• Detachable from computer unit
• Brightness/contrast
Backlighting
• Backlighting (type)
• MTBF backlighting
(up to 50%, at 25 °C)
• Dimmable backlight
Control elements
Function keys

5

Mouse/cursor control
• external mouse

USB

Touch operation
• Touch keyboard
Installation type/mounting
Built-in unit
• Permissible angle to the vertical
backward (console)
• Permissible angle to the vertical
forward (ceiling mounting)
Supply voltage
Type of actuation
• AC
• DC

USB
Yes

Yes

Yes
35°

Yes
35°

Yes
35°

Yes
35°

35°

35°

35°

35°

DC

DC
Yes
Yes

DC

DC
Yes
Yes

Yes

Yes

100 V; Up to 240V 50/60Hz

Rated voltage (AC)

100 V; Up to 240V 50/60Hz

Rated voltage (DC)

24 V

24 V

24 V

24 V

permissible range, lower limit (DC)

19.2 V

19.2 V

19.2 V

19.2 V

permissible range, upper limit (DC)

28.8 V

28.8 V

28.8 V

28.8 V

permissible range, lower limit (AC)

90 V

90 V

permissible range, upper limit (AC)

264 V

264 V

5/126

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
Industrial monitors and thin clients
SIMATIC Industrial Flat Panel

■ Technical specifications (continued)
6AV7 863-4AA00-0AA0
IFP2200
Power losses
Power loss AC
• Typical
• Maximum
Power loss DC
• Typical
• Maximum

6AV7 863-4AB10-0AA0
IFP2200

6AV7 863-4TA00-0AA0
IFP2200

40 W
60 W
40 W
65 W

Interfaces
USB on the rear

40 W
65 W

6AV7 863-4TB10-0AA0
IFP2200

40 W
60 W
40 W
65 W

40 W
65 W

2

2

Video interfaces
• DVI-D
• Display port

Yes
Yes; Display port V1.1

Yes
Yes; Display port V1.1

Yes
Yes; Display port V1.1

Yes
Yes; Display port V1.1

Touch interfaces
• USB

No

No

Yes

Yes

Degree and class of protection
IP65 at front

Yes

Yes

Yes

Yes

Enclosure Type 4 at the front

Yes

Yes

Yes

Yes

NEMA4 at the front

No

No

No

No

NEMA4X at the front

No

No

No

No

IP20 rear

Yes

Yes

Yes

Yes

Standards, approvals, certificates
CE

Yes

Yes

Yes

Yes

KC approval

Yes

Yes

Yes

Yes

cULus

Yes; Corresponds to
UL 508

Yes; Corresponds to
UL 508

Yes; Corresponds to
UL 508

Yes; Corresponds to
UL 508

C-TICK

Yes

Yes

Yes

Yes

GL

Yes; Available soon

Yes; Available soon

Yes; Available soon

Yes; Available soon

ABS

Yes; Available soon

Yes; Available soon

Yes; Available soon

Yes; Available soon

BV

Yes; Available soon

Yes; Available soon

Yes; Available soon

Yes; Available soon

DNV

Yes; Available soon

Yes; Available soon

Yes; Available soon

Yes; Available soon

LRS

Yes; Available soon

Yes; Available soon

Yes; Available soon

Yes; Available soon

Class NK

Yes; Available soon

Yes; Available soon

Yes; Available soon

Yes; Available soon

Use in hazardous areas
• ATEX Zone 22
• FM Class I Division 2

Yes; Available soon
Yes; Available soon

Yes; Available soon
Yes; Available soon

Yes; Available soon
Yes; Available soon

Yes; Available soon
Yes; Available soon

Ambient conditions
Min. ambient temperature

0 °C

0 °C

0 °C

0 °C

45 °C; Vertical installation
(horizontal)

45 °C; Vertical installation
(horizontal)

45 °C; Vertical installation
(horizontal)

45 °C; Vertical installation
(horizontal)

Storage/transport temperature
• Min.
• max.

-20 °C
60 °C

-20 °C
60 °C

-20 °C
60 °C

-20 °C
60 °C

Relative humidity
• Relative humidity during operation

95 %; Non-condensing

95 %; Non-condensing

95 %; Non-condensing

95 %; Non-condensing

1g
1g

1g
1g

1g
1g

1g
1g

15 g
15 g

15 g
15 g

15 g
15 g

15 g
15 g

Max. ambient temperature

Vibrations
• Vibration load in operation
• Vibration load during
transport/storage
Shock testing
• Shock loading in operation
• Shock load during transport/storage

Siemens ST 80 / ST PC · 2013

5/127

5

© Siemens AG 2013

PC-based Automation
Industrial monitors and thin clients
SIMATIC Industrial Flat Panel

■ Technical specifications (continued)
6AV7 863-4AA00-0AA0
IFP2200
Connection method
Connector for cooling devices

6AV7 863-4TA00-0AA0
IFP2200

Yes

6AV7 863-4TB10-0AA0
IFP2200
Yes

Mechanics/material
Type of housing (front)
• Aluminum

Aluminum
Yes

Aluminum
Yes

Aluminum
Yes

Aluminum
Yes

Dimensions
Width of the housing front

560 mm

560 mm

560 mm

560 mm

Height of housing front

380 mm

380 mm

380 mm

380 mm

Mounting cutout (W x H x D)
• Mounting cutout, width
• Mounting cutout, height

542 mm; Tolerance: +1 mm
362 mm; Tolerance: +1 mm

542 mm; Tolerance: +1 mm
362 mm; Tolerance: +1 mm

542 mm; Tolerance: +1 mm
362 mm; Tolerance: +1 mm

542 mm; Tolerance: +1 mm
362 mm; Tolerance: +1 mm

Depth/installation dimension

62.5 mm

62.5 mm

62.5 mm

62.5 mm

Weight
Weight without packaging

6.5 kg

6.5 kg

6.5 kg

6.5 kg

Weight incl. packaging

7.6 kg

7.6 kg

7.6 kg

7.6 kg

■ Ordering data
Industrial Flat Panel Monitor

Order No.

Order No.

6AV7863- 7 7 7 7 - 0 A A 0

Display size
• 15“
• 19“
• 22“

5

6AV7 863-4AB10-0AA0
IFP2200

2
3
4

Operator functionality
• Display devices without operator
functionality
• Touch screen (analog/resistive)
• Touch screen + function keys,
15" only and extended special
functions
Special functions
• Standard, can be located
up to 5 m away
• Extended, for positioning
at a distance of up to 30 m,
100 ... 230 V AC (without supply
cable) + special functions

A
T
BB1

Accessories
Set of protective films
for ITC/IFP/TP1500

6AV2124-6QJ00-0AX1

Set of protective films
for ITC/IFP/TP1900

6AV2124-6UJ00-0AX1

Set of protective films
for ITC/IFP/TP2200

6AV2124-6XJ00-0AX1

Touch pen
Undetachable pen for operation
of the touch devices,
mounting of the support on the
control cabinet or directly on the
PRO unit

6AV7672-1JB00-0AA0

A0

Accessories for standard variants
up to 5 m (6AV7863-..A0.-0AA0)

B1

DisplayPort cable
(industrial quality)
•3m
•5m

6AV7860-0DH30-0AA0
6AV7860-0DH50-0AA0

DVI-D cable (industrial quality)
•3m
•5m

6AV7860-0BH30-0AA0
6AV7860-0BH50-0AA0

USB cable (industrial quality)
•3m
•5m

6AV7860-0CH30-0AA0
6AV7860-0CH50-0AA0

Accessories for extended variants
up to 30 m (6AV7863-..B1.-0AA0)
Cable set (USB/Cat5;
sender module, DVI)
• 10 m
• 15 m
• 20 m
• 30 m

5/128

Siemens ST 80 / ST PC · 2013

6AV7860-1EX21-0AA1
6AV7860-1EX21-5AA1
6AV7860-1EX22-0AA1
6AV7860-1EX23-0AA1

Cable set 90°
USB/Cat5; sender module,
DVI 90° angle, 20 m

6AV7860-1EX22-0BA1

USB host extender
incl. 20 cm USB cable (USB to Cat5)

6AV7671-1EX02-0AA0

© Siemens AG 2013

PC-based Automation
Industrial monitors and thin clients
SIMATIC Industrial Flat Panel

■ Dimensional drawings
All dimensions in mm. For mounting cut-out see technical
specifications.

Mounting dimensions
Industrial
Flat Panel

H
D

W

Faceplate Dimensions, in mm

Mounting Cutout, in mm

W

H

W+1

H+1

D

IF1500
Key/Touch

483

310

450

291

62.5

IFP1500

415

310

396

291

62.5

IFP1900

483

337

465

319

62.5

IFP2200

560

380

542

362

62.5

6.5

G_ST80_XX_00522

H+1

W+1

5

Siemens ST 80 / ST PC · 2013

5/129

© Siemens AG 2013

PC-based Automation
Industrial monitors and thin clients
SIMATIC Flat Panels

■ Overview
The Flat Panels are rugged industry-standard LCD monitors.
• Installation:
- They are equally suited to installation in the machine, in
control cabinets, consoles and gantries or in 19" racks.
- As a device with all-round IP65 protection for mounting on
a supporting arm/stand
• Type of operator control:
- Simple display devices without operator functionality
- Optional devices with touch control
- Rear connection of I/O devices (optional)

■ Technical specifications
Flat Panel

12“

15“

19“

Supply voltage

24 V DC, additional option
100-240 V AC

24 V DC, additional option
100-240 V AC

24 V DC, additional option
100/240 V AC

Permissible frequency range

47 - 63 Hz

47 - 63 Hz

47 - 63 Hz

Power consumption, max.

25 VA

35 VA

55 VA

Anti-glare and hardened
mineral glass screen

Yes

Yes

Yes

Line side switch

No

No

No

Can be separate from the computer

Optional up to 30 m

Optional up to 30 m

Optional up to 30 m

On-screen display (OSD)
configuration

Yes

Yes

Yes

Display version

12" TFT

15" TFT

19" TFT

Visible area (HxV) in mm

246 x 184.5

304 x 228

376 x 301

Viewing angle

140° x 120°

140° x 120° (min)

170° x 170°

Pixel pitch

0.3075 mm x 0.3075 mm

0.297 mm x 0.297 mm

0.294 mm x 0.294 mm

Resolution (W x H in pixels)

800 x 600

1024 x 768

1280 x 1024

Refresh rate

60 - 75 Hz

60 - 75 Hz

60 - 75 Hz

Line frequency

25 - 48 kHz

46.7 - 62.5 kHz

30 - 80 KHz

Brightness/Contrast

> 350 cd/m² / 450:1

> 260cd/m² / 350:1

> 300cd/m² / 300:1

Number of colors

262k

16.7 million

16.7 million

MTBF backlit display
(at 25 °C, 24 h continuous duty)

50.000 h

50.000 h

50.000 h

Touch screen

analog-resistive, optional

analog-resistive, optional

analog-resistive, optional

Connection for mouse/keyboard/
barcode reader

Yes, at rear, optionally via USB

Yes, at rear, optionally via USB

Yes, at rear, optionally via USB

Front side according to EN 60529

IP65

IP65

IP65

Rear side according to EN 60529

IP20

IP20

IP20

Supply voltage

General features

5

Display

Type of operation

Degree of protection

5/130

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
Industrial monitors and thin clients
SIMATIC Flat Panels

■ Technical specifications (continued)
Flat Panel

12“

15“

19“

Certification

cULus (UL 508), NEMA4 tested

cULus (UL 508), NEMA4 tested

cULus (UL 508), NEMA4 tested

EMC

CE EN 55011 class A

CE EN 55011 class A

CE EN 55011 class A

CE mark

Yes

Yes

Yes

UL approval

Yes

Yes

Yes

CCC marking

Yes

Yes

Yes

Vibration load during operation

1 g (10 m/s²)

1 g (10 m/s²)

1 g (10 m/s²)

Shock loading during operation

5 g (50 m/s²)

5 g (50 m/s²)

5 g (50 m/s²)

5 to +50°C

5 to +50°C

5 to +45°C

Rack mounting

No

No

No

Front mounting

Yes (IP65)

Yes (IP65)

Yes (IP65)

Angle of inclination for desk mounting

-20°/+70°

-20°/+70°

-20°/+70°

Graphics interface

Standard VGA interface 15-pin
Sub D / digital DVI-D interface

Standard VGA interface 15-pin
Sub D / digital DVI-D interface

Standard VGA interface 15-pin
Sub D / digital DVI-D interface

Interface for Touch

USB (V1.1)

USB (V1.1)

USB (V1.1)

USB interface for touch screen

Optional

Optional

Optional

External dimensions
(W x H x D) in mm

400 x 310 x 61.5

483 x 310 x 54

483 x 400 x 56

Installation cutout/device depth
(W x H x D) in mm

368 x 290 x 51

450 x 290 x 54

449 x 380 x 56

5 kg

6.4 kg

10.2 kg

Certifications & standards

Standards, approvals, certificates

Ambient conditions

Temperature
Ambient temperature during operation
Mounting

Interfaces

Dimensions

Weight
Weight, approx.

Siemens ST 80 / ST PC · 2013

5

5/131

© Siemens AG 2013

PC-based Automation
Industrial monitors and thin clients
SIMATIC Flat Panels

■ Ordering data
Flat Panel Monitor

Order No.

Order No.

6AV7861- 7 7 7 7 0- 11 A A 0

Display size
• 12“
• 15“
• 19“

Flat Panel Monitor
• 12" Key
• 15" Key
• PRO 15" Touch
• PRO 19" Touch

1
2
3

Operator functionality:
• Display devices
without operator functionality
• Touch screen (analog/resistive)
Power supply
• 24 VDC
(not for Extended versions since
these always have AC and DC)
• 100 to 230 V AC (incl. Euro power
supply cable) and 24 V DC
Version
• Standard, can be located
up to 5 m away
• Extended, can be located
up to 30 m away,
marine approvals
Dimmable background illumination
Ex22

Special versions

A

Accessories

T
A

0

B

0
1

Protective films
For protecting the touch screen
against dirt and scratches
Pack with 10 units
• for 12" Touch
• for 15" Touch
• for 19" Touch
Touch pen
Undetachable pen for operation
of the touch devices,
mounting of the support on the
control cabinet or directly on the
PRO unit

5/132

Siemens ST 80 / ST PC · 2013

6AV7671-2BA00-0AA0
6AV7671-4BA00-0AA0
6AV7672-1CE00-0AA0
6AV7672-1JB00-0AA0

Connection cables for Standard,
Extended and PRO versions
• Video (VGA)
- 3.0 m
- 5.0 m

6AV7860-0AH30-0AA0
6AV7860-0AH50-0AA0

• Video (DVI-D)
- 3.0 m
- 5.0 m

6AV7860-0BH30-0AA0
6AV7860-0BH50-0AA0

• USB for optional touch screen
- 3.0 m
- 5.0 m

6AV7860-0CH30-0AA0
6AV7860-0CH50-0AA0

Connection cables for
Extended and PRO versions
• Cable set 10 m
(DVI-D, CAT5 cable (USB),
USB transmitter module)
• Cable set 15 m
(DVI-D, CAT5 cable (USB),
USB transmitter module)
• Cable set 20 m
(DVI-D, CAT5 cable (USB),
USB transmitter module)
• Cable set 30 m
(DVI-D, CAT5 cable (USB),
USB transmitter module)

5

6AV7861-1KB10-1AA0
6AV7861-2KB10-1AA0
6AV7861-5TB10-1BA0
6AV7861-6TB10-1BA0

6AV7860-1EX21-0AA1

6AV7860-1EX21-5AA1

6AV7860-1EX22-0AA1

6AV7860-1EX23-0AA1

© Siemens AG 2013

PC-based Automation
Industrial monitors and thin clients
SIMATIC Flat Panels

■ Dimensional drawings
All dimensions in mm. For mounting cut-out see technical specifications.
400

310

H
10.5

D

W

W+1 (cutout)

Installation cutout for Flat Panel

G_ST80_XX_00350

Flat Panel PRO 15" Touch

Front dimensions

Installation cutout

W

H

W+1

H+1

D

12"

400

310

368

290

51

15"

483

310

450

290

55

19"

483

400

450

380

57

483
SIMATIC FLAT PANEL

5
400

Touch devices

67.85

G_ST80_XX_00238

H+1 (cutout)

90.85

G_ST80_XX_00371

82

105

Flat Panel PRO 19" Touch

■ More information
Additional information is available on the Internet at:
http://www.siemens.com/industrial-lcd
Note:

Examples are:
• SIMATIC SCD monitor 1900 for portrait operation
• SIMATIC Flat Panels with 6" and 10" Touch

Do you need a specific modification or extension to the products
described here? Then refer to "Customized Automation". There
you will find information about additional and generally available
sector-specific products as well as options for customer-specific
modification and adaptation.

Siemens ST 80 / ST PC · 2013

5/133

© Siemens AG 2013

PC-based Automation
Industrial monitors and thin clients
SCD desk monitors SCD 19101

■ Overview

■ Technical specifications
19" monitors

SCD 19101-D/-DT

General features
Supply voltage
• Supply voltage
• Frequency/power consumption
• Line side switch
• Representation

The SCD 19101 D/DT monitors are LCD desktop monitors for
use in industry.
Type of operator control:
• Simple display devices
• Panels with touch control

Display
• Display version
• Screen diagonals
• visible area (HxV) in mm
• Viewing angle
• Pixel pitch
• Optimum resolution (in pixels)
• Refresh rate
• Line frequency
• Brightness/contrast (typical)
• Number of colors
• MTBF of backlit display
(up to 50%, at 25 °C)
Type of operation
• Function keys
• Membrane keyboard & piezo mouse
• Touch screen
Degree of protection
• Degree of protection
according to EN 60529

110/230 V AC
47 - 63 Hz/30 VA
No
Full screen
19" TFT
19"
359 x 287
170° x 170°
0.28 x 0.28
1280 x 1024
30 - 100 Hz
50 - 97 KHz
270 cd/m2/400:1
16 million
50,000 h

No
No
Optional
IP20

Ambient conditions
• Temperature
- Ambient temperature
during operation
Interfaces
• Interface design, analog video signal
(VGA)
• PS/2 interfaces for keyboard & mouse
• Serial interface for touch screen

5

Dimensions
• External dimensions
(W x H x D) in mm
• Installation cutout/depth
(W x H x D) in mm
• Weight in kg

■ Ordering data

5/134

Siemens ST 80 / ST PC · 2013

0 to +40°C

Yes
No
Optional/serial
465 x 444 x 91
(stand depth 240)
465 x 444 x 91
(stand depth 240)
7

Order No.

19" LCD monitors
SCD 19101-D, desktop model

6GF6220-1DA01

19" Touch LCD monitors
SCD 19101-DT, desktop model

6GF6220-1DB01

© Siemens AG 2013

PC-based Automation
Industrial monitors and thin clients
SCD desk monitors SCD 19101

■ Dimensional drawings
All dimensions in mm. For mounting cut-out see technical specifications.
465
15"

380

G_ST80_XX_00031

240

287.6

393

444

47

20

393

91

5"

160

SCD 19101-D/DT

■ More information
Additional information is available in the Internet under:
http://www.siemens.com/industrial-lcd

5

Siemens ST 80 / ST PC · 2013

5/135

© Siemens AG 2013

PC-based Automation
Industrial monitors and thin clients
SCD monitors 1900

■ Overview
The SIMATIC HMI SCD 1900 is a rugged, industry-standard PC
monitor.
It is used as an operator control unit in all types of industrial and
standard PC, including for portrait mounting. Standard interfaces permit a wide range of possible applications.
Built-in versions:
• Built-in unit (for control cabinets, control desks, and gantries)
• Built-in portrait for portrait mounting
(for control cabinets, control desks and gantries)
• 19" built-in units (for 19" racks)
Type of operator control:
• Panels with touch control

■ Technical specifications
6AV7862-2TA00-1AA0
SCD 1900

5

General information
Short designation

Flat Panel 19" Touch

Display
Screen diagonal

19 in

visible area (HxV) in mm

255 x 408

Viewing angle

160° x 170°

Type

TFT widescreen display,
LED backlighting

On Screen Display (OSD)
configuration

Yes

Number of colors (bit levels)

24 bit

Backlighting
• MTBF backlighting
(up to 50%, at 25 °C)

50 000 h

Installation type/mounting
Rack mounting possible

Yes

Built-in unit

Yes

VESA mounting

No

Supply voltage
Type of actuation
• AC
• DC

DC
Yes; With an external
power supply unit
Yes

permissible range, lower limit (DC)

21.6 V

permissible range, upper limit (DC)

26.4 V

5/136

Siemens ST 80 / ST PC · 2013

6AV7862-2TA00-1AA0
SCD 1900
Interfaces
Video interfaces
• VGA
• DVI-D

Yes
Yes

Touch interfaces
• USB

Yes

Degree and class of protection
IP65 at front

Yes

IP20 rear

Yes

Standards, approvals, certificates
CE

Yes; Industry

CSA

No

UL

Yes

cULus

Yes

Ambient conditions
Storage/transport temperature
• Min.
• max.

-20 °C
60 °C

Shock testing
• Shock loading in operation
• Shock load during transport/storage

10 g
10 g

Mechanics/material
Type of housing (front)
• Aluminum

Yes

Weight
Weight without packaging

6 kg

© Siemens AG 2013

PC-based Automation
Industrial monitors and thin clients
SCD monitors 1900

■ Ordering data

Order No.

SCD monitor 1900

6AV7862-2TA00-1AA0

Portrait SCD monitor 1900

6AV7466-2TA17-1AA0

■ Dimensional drawings
All dimensions in mm. For mounting cut-out see technical specifications.

Accessories

USB cable for connecting the
touch screen
• 3.0 m
• 5.0 m

6AV7860-0CH30-0AA0
6AV7860-0CH50-0AA0
6AV7860-2AD06-0AA0

483
W+1 (cutout)
H+1 (cutout)

External power supply
for SCD 1900
100-230 V AC, 50-60 Hz; incl.
mounting accessories for optional
installation at the device.

G_ST80_XX_00239

6AV7860-0AH30-0AA0
6AV7860-0AH50-0AA0
6AV7860-0BH30-0AA0
6AV7860-0BH50-0AA0

310

S

Cable for connecting to
the graphics interface of the PC
• VGA cable 3.0 m
• VGA cable 5.0 m
• DVI-D cable, 3.0 m
• DVI-D cable, 5.0 m

SCD 1900

5

Siemens ST 80 / ST PC · 2013

5/137

© Siemens AG 2013

PC-based Automation
Industrial monitors and thin clients
SCD monitors 1900

■ Dimensional drawings (continued)

18.5

18.5
1

63

23.3

105.1

114.4

Power
24V...

67

DVI

43

VGA

11

USB-Touch

136.5

310

133.6

57.7

6

1

483
1

5

with installed optional DC power supply unit

All dimensions in mm. For mounting cut-out see technical specifications.

■ More information
Additional information is available in the Internet under:
http://www.siemens.com/industrial-lcd

5/138

Siemens ST 80 / ST PC · 2013

81

G_ST80_XX_00429

11

62.5

1

© Siemens AG 2013

PC-based Automation
Industrial monitors and thin clients
SIMATIC Industrial Thin Client

■ Overview
SIMATIC ITC Industrial Thin Clients are powerful operating units
for flexible use in distributed visualization applications. All
devices are equipped with high-resolution, brilliant widescreen
displays, and due to the diverse communication protocols they
can be used both for challenging machine-level operator control
& monitoring and for the connection to control systems, e.g. in
the SCADA environment. They can be used as (additional)
operator stations on a SIMATIC Industrial PC, Panel PC, or
server, and on a SIMATIC Panel.
The following installation versions are available:
• SIMATIC ITC1200 – 12" Touch
• SIMATIC ITC1500 – 15" Touch
• SIMATIC ITC1900 – 19" Touch
• SIMATIC ITC2200 – 22" Touch
In addition to these devices, we continue to offer the SIMATIC
Thin Client 10", SIMATIC Thin Client 15", and SIMATIC Thin Client
PRO 15" for solutions in 4:3 format. These differ technically from
the SIMATIC ITC. For more details, refer to the SIMATIC Thin
Client chapter.
The SIMATIC HMI Thin Client Ex is available for hazardous
areas. This device differs technically from the devices
mentioned above. For more details, refer to the SIMATIC Thin
Client EX chapter.

■ Technical specifications
6AV6 646-1AA22-0AX0

6AV6 646-1AB22-0AX0

6AV6 646-1AC22-0AX0

6AV6 646-1AD22-0AX0

Display
Screen diagonal

12.1 in

15.4 in

18.5 in

21.5 in

Display width

261.1 mm

331.2 mm

409.8 mm

495.6 mm

Display height

163.2 mm

207 mm

230.4 mm

292.2 mm

Type

TFT widescreen display,
LED backlighting

TFT widescreen display,
LED backlighting

TFT widescreen display,
LED backlighting

TFT widescreen display,
LED backlighting

Number of colors

16 777 200

16 777 200

16 777 200

16 777 200

Resolution (pixels)
• Horizontal image resolution
• Vertical image resolution

1 280
800

1 280
800

1 366
768

1 920
1 080

General features
• PDF reader

Yes

Yes

Yes

Yes

Backlighting
• Backlighting (type)
• Dimmable backlight

LED, dimmable
Yes; 5-100 %

LED, dimmable
Yes; 5-100 %

LED, dimmable
Yes; 5-100 %

LED, dimmable
Yes; 5-100 %

Control elements
Mouse/cursor control
• USB

Yes

Yes

Yes

Yes

Keyboard fonts
• external keyboard
- USB

Yes

Yes

Yes

Yes

Touch operation
• Design as touch screen
- Analog, resistive
• Touch keyboard

Yes
Yes
Yes

Yes
Yes
Yes

Yes
Yes
Yes

Yes
Yes
Yes

Installation type/mounting
Built-in unit

Yes

Yes

Yes

Yes

Siemens ST 80 / ST PC · 2013

5/139

5

© Siemens AG 2013

PC-based Automation
Industrial monitors and thin clients
SIMATIC Industrial Thin Client

■ Technical specifications (continued)

5

6AV6 646-1AA22-0AX0

6AV6 646-1AB22-0AX0

6AV6 646-1AC22-0AX0

6AV6 646-1AD22-0AX0

Supply voltage
Type of actuation

24 V DC

24 V DC

24 V DC

24 V DC

permissible range, lower limit (DC)

19.2 V

19.2 V

19.2 V

19.2 V

permissible range, upper limit (DC)

28.8 V

28.8 V

28.8 V

28.8 V

Input current
Current consumption

1.2 A

1.5 A

1.3 A

2.2 A

Inrush current A²s

0.5 A²·s

0.5 A²·s

0.5 A²·s

0.5 A²·s

Interfaces
USB on the rear

2

2

2

2

USB at the front

0

0

0

0

Industrial Ethernet
• Transmission rate, max.
• Number of industrial Ethernet
interfaces

1 000 Mbit/s
1

1 000 Mbit/s
1

1 000 Mbit/s
1

1 000 Mbit/s
1

Protocols
Protocols (Ethernet)
• TCP/IP
• DHCP
• SNMP
• DCP
• LLDP

Yes
Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes
Yes

WEB characteristics
• HTTP
• HTML
• XML
• CSS
• JavaScript

Yes
Yes; HTML5
Yes
Yes
Yes

Yes
Yes; HTML5
Yes
Yes
Yes

Yes
Yes; HTML5
Yes
Yes
Yes

Yes
Yes; HTML5
Yes
Yes
Yes

Protocols (terminal link)
• Sm@rtServer
• RDP
• VNC viewer
• Citrix
• SINUMERIK

Yes
Yes
Yes
No
Yes

Yes
Yes
Yes
No
Yes

Yes
Yes
Yes
No
Yes

Yes
Yes
Yes
No
No

Protocols
PROFINET IO Device
• Services
- PROFIenergy

No

No

No

No

Degree and class of protection
IP65 at front

Yes

Yes

Yes

Yes

IP20 rear

Yes

Yes

Yes

Yes

Standards, approvals, certificates
CE

Yes

Yes

Yes

Yes

KC approval

Yes

Yes

Yes

Yes

cULus

Yes

Yes

Yes

Yes

C-TICK

Yes

Yes

Yes

Yes

Use in hazardous areas
• cULus Class I Zone 1
• cULus Class I Zone 2, Division 2
• FM Class I Division 2

No
Yes; Available soon
Yes; Available soon

No
Yes; Available soon
Yes; Available soon

No
Yes; Available soon
Yes; Available soon

No
Yes; Available soon
Yes; Available soon

5/140

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
Industrial monitors and thin clients
SIMATIC Industrial Thin Client

■ Technical specifications (continued)
6AV6 646-1AA22-0AX0

6AV6 646-1AB22-0AX0

6AV6 646-1AC22-0AX0

6AV6 646-1AD22-0AX0

Ambient conditions
Min. ambient temperature

0 °C

0 °C

0 °C

0 °C

Max. ambient temperature

50 °C

50 °C

45 °C

45 °C

Storage/transport temperature
• Min.
• max.

-20 °C
60 °C

-20 °C
60 °C

-20 °C
60 °C

-20 °C
60 °C

Relative humidity
• Relative humidity during operation

90 %

90 %

90 %

90 %

Software
Web browser

Yes

Yes

Yes

Yes

Yes
Yes; With Remote
Configuration Center (RCC)
as of V2.0

Yes
Yes; With Remote
Configuration Center (RCC)
as of V2.0

Yes
Yes; With Remote
Configuration Center (RCC)
as of V2.0

Yes
Yes; With Remote
Configuration Center (RCC)
as of V2.0

Yes
Yes

Yes
Yes

Yes
Yes

Yes
Yes

Yes; USB storage media
can be connected

Yes; USB storage media
can be connected

Yes; USB storage media
can be connected

Yes; USB storage media
can be connected

Mechanics/material
Type of housing (front)
• Aluminum

Yes

Yes

Yes

Yes

Dimensions
External dimensions (W x H x D)
• Width
• Height

330 mm
241 mm

415 mm
310 mm

483 mm
337 mm

560 mm
380 mm

Mounting cutout (W x H x D)
• Width
• Height
• Depth

310 mm
221 mm
82 mm

396 mm
291 mm
75 mm

465 mm
319 mm
75 mm

542 mm
362 mm
75 mm

Weight
Weight without packaging

3.4 kg

5.2 kg

6.5 kg

7.1 kg

Weight incl. packaging

4.1 kg

5.7 kg

7.1 kg

7.8 kg

Configuration
• On-board
• Remote administration

Languages
Online languages
• German
• English
I/O
I/O devices
• USB memory

Siemens ST 80 / ST PC · 2013

5

5/141

© Siemens AG 2013

PC-based Automation
Industrial monitors and thin clients
SIMATIC Industrial Thin Client

■ Ordering data
Industrial Thin Client
• SIMATIC ITC1200
12" Touch device
• SIMATIC ITC1500
15" Touch device
• SIMATIC ITC1900
19" Touch device
• SIMATIC ITC2200
22" Touch device

6AV6646-1AA22-0AX0

■ Dimensional drawings
All dimensions in mm. For mounting cut-out see technical
specifications.

6AV6646-1AB22-0AX0
6AV6646-1AC22-0AX0
6AV6646-1AD22-0AX0
See HMI accessories,
from page 2/96

H

Accessories

Order No.

D

W

6.5

G_ST80_XX_00522

H+1

W+1

Mounting dimensions
Industrial
Thin Client

5

Faceplate Dimensions, in mm

Mounting Cutout,
in mm

W

H

W+1

H+1

D

ITC1200

330

241

310

221

82

ITC1500

415

310

396

291

75

ITC1900

483

337

465

319

75

ITC2200

560

380

542

362

75

■ More information
Additional information is available on the Internet at:
http://www.siemens.com/simatic-itc

5/142

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
Industrial monitors and thin clients
SIMATIC Thin Client

■ Overview
SIMATIC Thin Clients are very economical operator panels
which can be used flexibly in various distributed applications.
They can be used as (additional) operator stations on a
SIMATIC industrial PC or also on a SIMATIC Panel.
The following versions are available:
• The rack-mounting versions SIMATIC Thin Client 10" Touch
and SIMATIC Thin Client 15" Touch
• The support arm version SIMATIC Thin Client PRO 15" Touch
with a rugged and very compact aluminum enclosure which is
completely IP65 protected
The new high-performance SIMATIC ITC Industrial Thin Clients
with high-resolution touch displays in widescreen format from
12" to 22" are available for demanding terminal applications.
There are technical differences to the SIMATIC Thin Client.
For more information, see SIMATIC Industrial Thin Client.
The SIMATIC HMI Thin Client Ex is available for hazardous
areas. This device differs technically from the devices
mentioned above.

■ Technical specifications
6AV6646-0AA21-2AX0
10" Touch

6AV6646-0AB21-2AX0
15" Touch

Display
Size

10.4"

15.1"

Display type

TFT, 65536 colors

TFT, 65536 colors

Resolution (pixels)
• Resolution (WxH in pixel)

640 x 480

1024 x 768

Backlighting
• MTBF backlighting (at 25 °C)

about 50000 hours

about 50000 hours

Control elements
Control elements

Touch screen

Touch screen

USB / USB

USB / USB

Touch operation
• Touch screen

Analog, resistive

Analog, resistive

Supply voltage
Supply voltage

24 V DC

24 V DC

Processor
Processor

ARM, 266 MHz

ARM, 266 MHz

Memory
Type

Flash / RAM

Flash / RAM

Interfaces
Interfaces

1 x Ethernet (RJ45)

1 x Ethernet (RJ45)

USB port

1 x USB

1 x USB

Industrial Ethernet
• Industrial Ethernet interface

1 x Ethernet (RJ45)

1 x Ethernet (RJ45)

Connection for mouse/keyboard/
barcode reader

Siemens ST 80 / ST PC · 2013

5

5/143

© Siemens AG 2013

PC-based Automation
Industrial monitors and thin clients
SIMATIC Thin Client

■ Technical specifications (continued)
6AV6646-0AA21-2AX0
10" Touch

6AV6646-0AB21-2AX0
15" Touch

Protocols
WEB characteristics
• HTTP
• HTML
• XML
• CSS
• JavaScript

Yes
Yes
Yes
Yes
Yes

Yes
Yes
Yes
Yes
Yes

Protocols (terminal link)
• Sm@rtServer
• RDP

Yes
Yes

Yes
Yes

EMC
Emission of radio interference
acc. to EN 55 011
• Emission of radio interferences
acc. to EN 55 011 (limit class A)

Yes; EN 61000-6-4, interference emission:
Intended for use in industrial areas.

Degree and class of protection
Front

IP54, NEMA 12, (when installed)

IP54, NEMA 12, (when installed)

Rear

IP20

IP20

CE, cULus, C-TICK, NEMA 12 (when installed: IP54,
enclosure type 12; optional IP65, enclosure
type 4X/type 12 (6AV6671-6AP00-0AX0))

CE, cULus, C-TICK, NEMA 12 (when installed: IP54,
enclosure type 12; optional IP65, enclosure type
4X/type 12 (6AV6671-6AP00-0AX0))

EMC

The product is designed for use in industrial environments. When used in residential areas, the emission of
radio interference according to limit class B of EN 55011
must be ensured. For further information please refer to
the user documentation.

The product is designed for use in industrial environments. When used in residential areas, the emission of
radio interference according to limit class B of EN 55011
must be ensured. For further information please refer to
the user documentation.

Suitable for safety functions

No

No

Ambient conditions
maximum permissible angle of
inclination without external ventilation

+/- 35 °

+/- 35 °

Storage/transport temperature
• Transport, storage

-20 °C to +60 °C

-20 °C to +60 °C

Relative humidity
• max. relative humidity

85 %; (Storage)

Dimensions
Front of enclosure (W x H)

325 mm x 263 mm

400 mm x 310 mm

Weight
Weight

2.2 kg

3.6 kg

Standards, approvals, certificates
Certifications

5

■ Ordering data
SIMATIC Thin Client
• 10" Touch device
• 15" Touch device

Order No.
6AV6646-0AA21-2AX0
6AV6646-0AB21-2AX0

Starter kits
SIMATIC Thin Client
with Sm@rtAccess
(License to operate
SmartAccess on the server)
• Touch device 10" with
Sm@rtAccess license (panels)
• Touch device 15" with
Sm@rtAccess license (panels)
• Touch device 15"PRO with
Sm@rtAccess license (panels)
• Touch device 10" with
Sm@rtAccess license for
WinCC flexible 2008 Runtime
• Touch device 15" with
Sm@rtAccess license for
WinCC flexible 2008 Runtime
• Touch device 15" PRO with
Sm@rtAccess license for
WinCC flexible 2008 Runtime

5/144

Order No.
Option packages

6AV6653-6AA01-2AA0
6AV6653-6BA01-2AA0
6AV6653-6CA01-2AA0
6AV6653-6DA01-2AA0

6AV6653-6EA01-2AA0

6AV6653-6FA01-2AA0

Siemens ST 80 / ST PC · 2013

IP65 set
(upgrade from IP54 to IP65)

6AV6671-6AP00-0AX0

Accessories

See HMI accessories,
from page 2/96

© Siemens AG 2013

PC-based Automation
Industrial monitors and thin clients
SIMATIC Thin Client

■ Dimensional drawings
All dimensions in mm. Tolerance ± 1 mm.
59.9

6.2

400

59.9

6.2

310

63.21

288
113.59

247
106.71

275

113.59

335

30

SIMATIC Thin Client 10" Touch

366
232.49

G_ST80_XX_00306

232.49

30
G_ST80_XX_00305

309

SIMATIC Thin Client 15" Touch

■ More information
Additional information is available in the Internet under:
http://www.siemens.com/simatic-thin-client

5

Siemens ST 80 / ST PC · 2013

5/145

© Siemens AG 2013

PC-based Automation
RMOS3 real-time operating system
RMOS3 real-time operating system

■ Overview
SICOMP RMOS3

RMOS3-TCP/IP V3.0

RMOS3 is a real-time and multitasking-capable operating
system. In addition to real-time capability, which ensures fast
response times, deterministic behavior is also an important
feature. This guarantees response times within a short time
interval.

The RMOS3-TCP/IP V3.0 software package offers the application developer a wide range of options for implementing TCP/
UDP-based communication tasks running under the real-time
operating system RMOS3, V3.40 or higher.

Rugged operating systems guarantee reliable behavior even
under exceptional circumstances. RMOS3 has been optimized
for use in embedded applications. In harsh environments, the
rugged memory cards or CompactFlash memories can be used
instead of hard disks. In addition, RMOS3 is suitable for
operation with or without an operator.
RMOS3 V3.50 Real-Time Operating System
With the RMOS3 V3.50, Intel Core i processors with up to
2 cores/4 threads are now also supported. The "Symmetric
Multicore Processing" (SMP) mode makes it possible to
implement complex applications that are simultaneously
processed on multiple processor cores. RMOS3 V3.50 ensures
that the cores are symmetrically utilized so that a performance
increase of up to 100% can be achieved on the SIMATIC IPC
with 2 processors.

5

Apart from the usual UDP and TCP protocols for application
development, the new version of RMOS3-TCP/IP not only
provides Address Resolution Protocol (ARP), Multicast and
ICMP services (Ping), but also client services for the DHCP
(Dynamic Host Configuration Protocol), DNS (Domain Name
System), NTP (Network Time Protocol) and SMTP (Simple Mail
Transfer Protocol).
Together with the FTP programming interface and the Web
server with process data connection, the programmer obtains
numerous programming interfaces for even greater flexibility in
communication.
RMOS3-GRAPHX V1.0
With the RMOS3-GRAPHX product, window-based, graphical
user interfaces can be implemented with the RMOS3 real-time
operating system Version V3.30 or higher.

The new RMOS3 real-time operating system is characterized by
increased security thanks to memory protection, minimum
interrupt response times and fast hard disk access. For SIMATIC
IPCs, automation solutions based on C/C++ with demands for
hard real time, deterministic response and high performance
can now be created more easily, conveniently and with greater
stability.

Extensive graphical libraries increase the user-friendliness of the
system and support cost savings due to centralization of the
control and operation on a CPU.

RMOS3-GNU V3.0

BSP SIMATIC IPC V4.0 for RMOS3

The RMOS3-GNU software package uses generally available
Linux tools with which users can easily create real-time applications for RMOS3 on the SIMATIC IPC.

The Board Support Package BSP SIMATIC IPC V4.0 for
RMOS3 is a software package for supporting all interfaces
(e.g. PROFINET onboard) and other onboard functions
(e.g. battery monitoring, watchdog) for the following industrial
PCs: SIMATIC IPC227D, SIMATIC IPC427C, SIMATIC IPC627C,
SIMATIC IPC 827C, SIMATIC IPC647C and SIMATIC IPC847C.

The GNU-based software tools for Windows XP/Vista/Windows 7
computers comprise the assemblers, C/C++ compilers, linkers
and debuggers familiar in the Linux environment as well as the
Eclipse development interface. The integrated cross debugger
is useful for commissioning the customer application since the
development and target system can be connected via TCP/IP.
C/C++ header files and libraries are available for applications
which use RMOS3 Version 3.30 or higher.

5/146

Siemens ST 80 / ST PC · 2013

With a Graphical User Interface (GUI), familiar from Windows,
window displays can be implemented with the familiar command
elements in the form of buttons, toolbars, scrollbars, selection
lists and symbols as well as dialog boxes for prompts or inputs.

© Siemens AG 2013

PC-based Automation
RMOS3 real-time operating system
RMOS3 V3.50 real-time operating system

■ Overview
RMOS3 is the real-time and multitasking-capable operating
system from Siemens for implementing your automation solution
with the programming languages C and C++. In mechanical
engineering or in the manufacture of machine tools RMOS3 is
used in test beds, packaging or printing machines where high
response times in conjunction with open and closed-loop control
tasks are required.
The new RMOS3 real-time operating system is characterized by
increased security thanks to memory protection, minimum
interrupt response times and fast hard disk access.
Furthermore, with the RMOS3 V3.50 version, Intel Core i
processors with up to 2 cores/4 threads are now also supported.
The "Symmetric Multicore Processing" (SMP) mode makes it
possible to implement complex applications that are simultaneously processed on multiple processor cores. RMOS3 V3.50
ensures that the cores are symmetrically utilized so that a performance increase of up to 100% can be achieved on the
SIMATIC IPC with 2 cores.
For SIMATIC IPC, automation solutions based on C/C++ with
demands for hard real time, deterministic response and high
performance can now be created more easily, conveniently and
with greater stability.
RMOS3 has been optimized for use on PC platforms in
embedded systems and fulfills industrial requirements with
respect to:
• Real-time and multitasking capability
• Deterministic features
• Ruggedness
• Scalability/memory requirements
• Operation with or without an operator
• Modern development tools
• Quality assurance
• Warranty conditions
• Service & Support

■ Technical specifications
System requirements for the development system
• PC with Windows XP, Windows Vista or Windows 7
Required software components:
• RMOS3 development environment as of RMOS3 V3.40
• RMOS3-GNU as of V2.1, compiler and development interface
• Board Support Packages
(optional, module-specific expansion packages)
System requirements for target system
• SIMATIC IPC427C
• SIMATIC Box PC 627B/827B, IPC627C
• SIMATIC Rack PC 647B/847B, IPC647C, IPC847C
Required software components:
• RMOS3 V3.50 runtime environment
(RMOS nucleus and service programs)
• Board Support Packages (optional, module-specific drivers)
Product structure, listed acc. to development and
runtime licenses
Product name

Description

RMOS3 V3.50 EL

Single license for RMOS3
development environment
incl. a RMOS3 runtime license
comprising

RMOS3 V3.50 EL Update

• Sources and libraries for
application creation
• RMOS3 runtime environment incl.
loadable programs and TCP/IP
stack and 10/100 Mbit/s LAN
drivers
• Configurable RMOS3 Nucleus for
the Use on SIMATIC IPCs
• Examples and documentation
Single license for the GNU
development tools incl.
• Compiler, linker, debugger
and Eclipse IDE
• Special RMOS3 libraries for
application creation
• Example projects and
documentation

RMOS3-GNU V3.0 EL
RMOS3-GNU V3.0 EL Update

BSP-SIMATIC IPC 4.0 EL 1)
BSP SIMATIC IPC V4.0 EL Update 1)

RMOS3-TCP/IP V3.0 EL 1)
incl. German documentation
RMOS3-TCP/IP V3.0 EL Update 1)
RMOS3-PC IO V2.0

1)

• Single license for IPC227D,
IPC427C, IPC627C, IPC827C,
IPC647C, IPC847C incl. runtime
license for BSP (no runtime license
for RMOS3 V3.50):
• Configurable nucleus
• Driver for
USB, LAN, PROFINET IO,
PROFIBUS DP, BasicCAN
• GNU example projects and documentation
Master license for
TCP/IP communication
• Application development with
socket interface
• Programming interface for FTP
Free download as programming
example with programming interface for access to PC I/O modules

Optional Board Support Packages (BSP)

Siemens ST 80 / ST PC · 2013

5/147

5

© Siemens AG 2013

PC-based Automation
RMOS3 real-time operating system
RMOS3 V3.50 real-time operating system

■ Technical specifications (continued)
Product structure – Runtime licenses
Product name

Description

RMOS3 V3.50 RT

Single RMOS3 V3.50 runtime
license

RMOS3-TCP/IP V3.x RT 1)

• Single RMOS3 TCP/IP runtime
license
• Required for application programs
with socket interface

RMOS3-CANopen168 1)

Single runtime license with software
package when the CPCI-COM168
module is used in networks with
CANopen

BSP SIMATIC IPC RT V4.x 1)

Single runtime license for BSP

Supported boot media
• Disk
• Hard disk
• IDE flash disk
• LAN (on request)
Available drivers for
RMOS3 V3.50
The drivers described below are currently available for RMOS3 V3.50
• PS2 keyboard

Keyboard

• USB keyboard 1)
Serial, parallel

• Universal I/O driver (BYT driver) for
character-oriented I/O devices
• COM driver for 3964(R) protocol
Transmission mode and baud rate
configurable
• EGA (text mode)

Graphics

• Semi-graphical interface
(function library on request)

5

• RMOS3-GRAPHX (graphics library
for pixel graphics window
displays) 1)
10/100/1000 Mbit/s LAN driver:

Ethernet

• IPC227D, IPC427C, IPC627C,
IPC827C, IPC647C, IPC847C
• Filter functionality, configurable
transfer rates and transfer modes
USB 1)

• Optional USB driver for USB 1.1
protocol and USB 2.0 protocol
• Support for keyboard, mouse,
hub, memory stick and CD-ROM
(on request)
• Module driver for operating the
CP 1616-compatible PROFINET
components (CP 1616, CP 1604,
SIMATIC IPC with PROFINET
onboard)

PROFINET IO

• Supports the ERTEC 400 controller, RT and IRT, IO Controller and/or
IO Device
PROFIBUS DP 1)

• Module driver and programming
interface for SIMATIC PC with
PROFIBUS onboard, CP5611 compatible, DPV0 master and/or slave

CAN 1)

• BasicCAN driver for connection to
CAN bus
• Supports the SJA1000 CAN
controller on SIMATIC IPC427C

1)

Optional Board Support Packages (BSP)

5/148

Siemens ST 80 / ST PC · 2013

■ Ordering data

Order No.

RMOS3 V3.50 EL
Single license for RMOS3 development environment incl. a RMOS3
runtime license

6AR1405-0EA00-1AA4

RMOS3 V3.50 EL Update
Update from V3.40 to V3.50. Single
license for RMOS3 development
environment incl. a RMOS3 runtime
license

6AR1405-0EA50-1AA4

RMOS3 V3.50 RT
Single RMOS3 V3.50 runtime
license

6AR1403-0DA3

© Siemens AG 2013

PC-based Automation
RMOS3 real-time operating system
RMOS3-GNU V3.0

■ Overview
RMOS3-GNU V3.0 is a software package that supports development and testing of applications for the real-time operating
system RMOS3 (Version 3.40 and higher).
It builds on a GNU-based tool chain that is well-known and
widely implemented in the Linux environment and contains the
expansions required for RMOS3.
RMOS3-GNU V3.0 replaces the existing RMOS3-GNU V2.x
product. An update from RMOS3-GNU V2.x to Version V3.0 is
available.
RMOS3-GNU V3.0 contains the following new functions:
• Up-to-date versions of the GNU tool chain,
e.g. C/C++ compiler V3.4.1
• Updated versions of Eclipse V3.4 and CDT plug-in V5.0.
• New Eclipse "terminal" plug-in for remote operation of the
target system
• New Eclipse "profiling" plug-in for determining the system load
and the task activity on the target system
• Extended Eclipse "remote launcher" plug-in for testing the
applications on Privilege Level 0 or alternatively on Privilege
Level 1

■ Technical specifications
System requirements: Development system
• Windows XP, Windows Vista, or Windows 7
• Java Runtime Environment, Version 1.5 and higher
(only necessary when using Eclipse IDE)
• RMOS3 development environment RMOS3 Version 3.40
(incl. software fix RMOS3 V3.40.02) or RMOS3 V3.50
(incl. software fix RMOS3 V3.50.04)
System requirements: Target system
• RMOS3 version 3.40.02 and higher or version 3.50.04
(configurable nucleus V3.30.06 R01)
Licenses
The GNU-based tool chain is subject to the GNU GENERAL
PUBLIC LICENSE (GPL) or
the GNU LESSER GENERAL PUBLIC LICENSE (LGPL).
Please read the licensing rules supplied with the product.

■ Ordering data

Order No.

SICOMP RMOS3-GNU V3.0 EL
Single license for the GNU development tools incl. compiler, linker,
debugger and Eclipse IDE,
special RMOS3 libraries for creating
applications, project examples and
documentation

6AR1405-0BA00-1CA0

SICOMP RMOS3-GNU V3.0 EL
update
Update V2.x to V3.0, development
package, single license, CD-ROM,
including description in German in
PDF format

6AR1405-0BA50-1CA0

5

Siemens ST 80 / ST PC · 2013

5/149

© Siemens AG 2013

PC-based Automation
RMOS3 real-time operating system
RMOS3-TCP/IP V3.0

■ Overview

■ Ordering data

The RMOS3-TCP/IP V3.0 software package provides libraries for
the quick and easy generation of TCP/IP, FTP and Web applications. In addition, the software package offers FTP and Telnet
services for the exchange of files and for the remote maintenance of the RMOS3 system. New additions are the DHCP, DNS,
NTP and SMTP services for even greater flexibility in communication.

■ Technical specifications
System requirements for the development system
• PC with Windows XP, Windows Vista or Windows 7
Required software components:
• RMOS3 development environment as of RMOS3 V3.40
• RMOS3-GNU as of V2.1, compiler and development interface
• Board support packages
(optional, module-specific expansion packages)
System requirements for target system
• SIMATIC Microbox PC IPC427C
• SIMATIC Box PC 627B/IPC627C
• SIMATIC Box PC 827B
• SIMATIC Rack PC 647B/IPC647C
• SIMATIC Rack PC 847B/IPC847C
Required software components:
• RMOS3 V3.40 or higher runtime environment
(RMOS nucleus and service programs)
• Board support packages (optional, module-specific drivers)

5

5/150

Siemens ST 80 / ST PC · 2013

Order No.

SICOMP RMOS3-TCP/IP V3.0 EL
Development package, single
license, TCP/IP software for RMOS3
V3.40 or higher, CD-ROM, including
description in German in PDF format

6AR1403-0AN00-1BA0

SICOMP RMOS3-TCP/IP V3.0 EL,
update from V2.3 to V3.0
Development package, single
license, TCP/IP software for RMOS3
V3.40 or higher, CD-ROM, including
description in German in PDF format

6AR1403-0AN50-1BA0

SICOMP RMOS3-TCP/IP V3.x
Runtime license
Runtime license for TCP/IP software
V3.0 or higher for use with RMOS3
V3.40 or higher

6AR1403-0BN3

© Siemens AG 2013

PC-based Automation
RMOS3 real-time operating system
RMOS3-GRAPHX V1.0

■ Overview
RMOS3-GRAPHX V1.0 provides you with a comprehensive
graphics package which enables you to expand your C/C++
based automation solution under SICOMP RMOS3 with a userfriendly graphics interface for operator control and monitoring.
Use of the Qt-based graphics library of the Norwegian company
Trolltech-Nokia (www.gt.nokia.com) allows window-based interfaces to be created with a "look and feel" and input facilities
comparable to Windows. Real-time characteristics are
maintained within the multi-tasking RMOS3 operating system
environment.
In combination with the widely used development tools GNU,
Eclipse and the QT Designer from Trolltech-Nokia, convenient
development tools are available to you for creating your real-time
applications on approved SIMATIC IPC hardware.

■ Technical specifications
System requirements for the development system
• PC with Windows XP, Windows Vista or Windows 7
Required software components:
• RMOS3 development enviroment RMOS3 V3.40 or higher or
RMOS3 V3.30 including software fix RMOS3 V3.30.04
• RMOS3-GNU as of V2.1, compiler and development interface
• For RMOS3-GNU V3.0 or higher, an update for
RMOS3-GraphX V1.1 is offered via Customer Support:
http://www.siemens.com/automation/support-request
• RMOS3-GRAPHX V1.0, graphics package for creation of
graphics interfaces for RMOS3
• Update RMOS3-GraphX V1.1 in connection with RMOS3-GNU
V3.0 or higher is available via Customer Support:
http://www.siemens.com/automation/support-request
• Qt Desktop Light Edition for Windows from Trolltech-Nokia
(www.gt.nokia.com)
Optional:
• Board support packages
(optional, module-specific expansion packages)
System requirements for target system
• SIMATIC IPC
Required software components:
• RMOS3 V3.40 or higher runtime environment
(RMOS nucleus and service programs)
• RMOS3-GRAPHX V1.0 runtime license
(graphics support, USB driver)
Optional:
• Board support packages
(optional, module-specific drivers)

■ Ordering data

5

Order No.

RMOS3-GRAPHX V1.0 EL
Master license for graphic library for
the creation of window-oriented
interfaces of RMOS3 Version 3.30
and higher

6AR1403-0BG00-1AA0

Qt Desktop Light Edition
Single Platform Windows
development package

Obtainable from
Trolltech-Nokia,
www.gt.nokia.com

Qt Desktop Light Edition V4.1.4 for
Windows, incl. Qt Designer

Siemens ST 80 / ST PC · 2013

5/151

© Siemens AG 2013

PC-based Automation
RMOS3 real-time operating system
BSP SIMATIC IPC V4.0 for RMOS3

■ Overview

■ Ordering data

The Board Support Package BSP SIMATIC IPC V4.0 supports
SIMATIC IPC devices of the C generation and the D generation
starting with the NANOBOX PC IPC227D. The following SIMATIC
IPCs can therefore now be operated along with their PROFINET
onboard functionality, PROFIBUS, CAN, and hardware-based
functions with the real time operating system RMOS3 V3.50 and
higher:
• IPC227D
• IPC427C and IPC427D
• IPC627C and IPC827C
• IPC647C and IPC847C

■ Technical specifications
System requirements for the development system
• PC with Windows XP, Windows Vista or Windows 7
Required software components:
• RMOS3 development environment as of RMOS3 V3.50
• RMOS3-GNU V3.0 and higher, compiler and development
interface
• Board Support Packages
(optional, module-specific expansion packages)
System requirements for target system
• SIMATIC IPC227D
• SIMATIC IPC427C and IPC427D
• SIMATIC IPC627C and IPC827C
• SIMATIC IPC647C and IPC847C

5

Required software components:
• RMOS3 V3.50 or higher runtime environment
(RMOS nucleus and service programs)
• Board Support Packages
(optional, module-specific drivers)

5/152

Siemens ST 80 / ST PC · 2013

BSP SIMATIC IPC V4.0 EL

Order No.
6AR1403-0BC00-1DA0

Board Support Package for
SIMATIC IPC227D,
SIMATIC IPC427C,
SIMATIC IPC627C, IPC827C,
SIMATIC IPC647C, and IPC847C
for use with the SICOMP RMOS3
operating system V3.50 and higher,
development package,
single license, runtime license,
CD-ROM, including description in
German in PDF format,
RMOS3 runtime license V3.50 and
higher not included.
BSP SIMATIC IPC V4.0 EL Update

6AR1403-0BC50-1DA0

Update from BSP SIMATIC IPC V3.1
to BSP SIMATIC IPC V4.0
BSP Nanobox IPC V1.x RT
Package

6AR1403-1DC3

License bundle comprising RMOS3
V3.50 RT, RMOS3-TCP/IP V3.x RT
and BSP SIMATIC IPC V4.x RT
runtime licenses for use with the
Nanobox PC IPC227D.
BSP SIMATIC IPC V4.x RT
Runtime license for Board Support
Package BSP SIMATIC IPC V4.0 EL
for
• SIMATIC IPC227D
• SIMATIC IPC427C
• SIMATIC IPC627C, IPC827C
• SIMATIC IPC647C, IPC847C for
use with the SICOMP RMOS3
operating system V3.50 and higher

6AR1403-0DC3

© Siemens AG 2013

PC-based Automation
Expansion components and accessories
Expansion components / accessories

■ Overview
SIMATIC PCs offer users a wide range of designs and systems
which perfectly match industrial applications and fulfill the high
requirements in terms of ruggedness.
These include e.g.:
• Wide temperature of use up to 55 °C
• High resistance to vibration/shock
• Rugged housing design
• Special degrees of protection up to IP65, NEMA 4
• High electromagnetic compatibility (EMC)
• UL, CE industry certification
• Integral industrial power supplies (NAMUR)
• Easy-to-service design for rapid replacement of faulty
components
Increased system availability
A graded concept is available for effective early detection of
potential failures and minimization of actual downtimes. This
consists of hardware and software expansion options specially
developed for SIMATIC PCs with which the system availability
can be individually increased depending on the safety requirements.
The use pays off:
Because the safety is significantly increased by components
such as a second hard disk for additional data backup or the
DiagMonitor for permanent self-diagnostics. The system availability options thus make a contribution to the significant minimization of the total costs (TCO) of the installation according to the
motto: "Small effort, large effect".
The following components are available:
Hard disks options
• Solid-state drive (SSD)
• Second hard disk:
The safety of the data stored on the hard disk is a cornerstone
for system availability.
- Simple and fast data backup of complete installation and
user data in combination with the SIMATIC IPC Image &
Partition Creator.
- Following a faulty software installation or in the case of a hard
disk defect, the system can be immediately put back into
operation by booting the back-up disk.
- Fast download of the last saved hard disk image to the
working disk.
Two hard disks are optionally available in a user-friendly swap
frame for the Rack PC to permit fast and easy data backup.

SIMATIC IPC CompactFlash/SIMATIC IPC CFast
The application of PCs in industrial areas requires rugged
systems to prevent or minimize production downtimes. SIMATIC
IPCs have been developed precisely for this purpose. One way
of improving the industrial suitability and system availability of
SIMATIC IPCs even further is to use SIMATIC PC CompactFlash
cards instead of hard disk drives. These are system-tested with
the SIMATIC IPCs.
SIMATIC PC CompactFlash is a hardware option that can be
ordered via the relevant SIMATIC IPC configurator or separately
as an accessory.
The SIMATIC IPC CFast memory cards are readily replaceable
mass storage units for SIMATIC IPC427D and IPC477D. They
are connected via a SATA interface.
As a result of the different interface, the SIMATIC IPC CFast
memory cards are not compatible with the SIMATIC IPC
CompactFlash memory cards.
SIMATIC IPC USB FlashDrive
• Mobile memory medium for SIMATIC IPC/PG
• Fast data transfer (USB 2.0) and high memory capacity
• Ultra-compact and rugged
• Preinstalled SIMATIC IPC BIOS Manager
SIMATIC IPC Service USB FlashDrive
The SIMATIC IPC Service USB FlashDrive is the ideal tool for
maintenance as well as saving and restoring of data. With the
preinstalled SIMATIC IPC Image & Partition Creator and
SIMATIC IPC BIOS Manager, the FlashDrive is immediately
ready for use.
Central I/O expansion PC IO
The PC IO expansion comprises:
• Basic module with encoder/counter functionality, PCI104
interface to the host system, and communication interfaces to
the I/O modules
• Digital and analog I/O modules that are managed by the basic
module
• Mechanical installation components
Industrial USB Hub 4 (see HMI accessories, page 2/96)
• The Industrial USB Hub 4 is essentially used as a USB hub for
the connection of I/O devices to Multi Panels and Panel PCs
with an integral USB interface
• USB I/O devices can be connected to the panel and operated
via the USB Hub 4 without opening the cabinet door
• The Industrial Hub 4, in contrast to commercially available
USB hubs, can be used in harsh industrial environments
(IP65)
SIMATIC Panel PC Remote Kit
• Separation of computer unit and operator control unit
• At a maximum distance of up to 30 m
• Pure hardware solution, no need to install additional software
• Maintaining the full Panel PC front functionality

Siemens ST 80 / ST PC · 2013

5/153

5

© Siemens AG 2013

PC-based Automation
Expansion components and accessories
Expansion components / accessories

■ Overview (continued)
SIMATIC IPC Image & Partition Creator
• Software tool for preventive data backup of hard disk contents
• High-speed restoring of system and data partitions with bit
accuracy; user software and special installations are also
backed up
• Software tool for editing the hard disk partitioning

ADDM Data Management

SIMATIC IPC DiagMonitor
• Diagnostic and alarm software for monitoring SIMATIC IPCs
• Comprehensive monitoring of temperature, fans, hard disks
(SMART, RAID, CF Card, SSD), watchdog
• Operating hours counter for preventive maintenance
• Integrated log functions, comprehensive text messages,
online help (English/German)

DC-UPS uninterruptible power supplies

SIMATIC IPC Remote Manager
Efficient remote maintenance and management of
SIMATIC IPCs.
With the SIMATIC IPC Remote Manager you can use functions of
the Intel Active Management Technology (Intel AMT) for
SIMATIC IPCs. Intel AMT is used for remote management of PCs.
SIMATIC IPC BIOS Manager
The SIMATIC IPC BIOS Manager is a software tool with which
CMOS data from the BIOS configuration of a SIMATIC IPC can
be edited. The tool is obtained by downloading it from the
Internet using the Automation Value Card from Customer
Support.

5

5/154

Siemens ST 80 / ST PC · 2013

With ADDM, you are completely in control of the SIMATIC and
SINUMERIK controllers – around the clock and with any program
version. This tool, indispensable in modern production systems,
allows user-friendly backup, comparison and management of
control data.

The uninterruptible DC power supply with battery modules
consists of DC UPS modules.
The maintenance-free SITOP UPS500 with capacitors as energy
stores are especially suitable for use at high ambient temperatures. A further advantage of these high-capacity double-layer
capacitors is their shorter charging times.
For flexible use, there is the SITOP UPS500S – 15 A basic unit in
2.5 kW and 5 kW versions. Up to 3 SITOP UPS501S expansion
modules of 5 kW each can be connected in parallel to extend the
backup times. The SITOP UPS500P IP65 version has capacitors
for 5 or 10 kW and supplies up to 7 A output current.
Input and output devices
The SIMATIC IPC accessories encompass various input
devices.

© Siemens AG 2013

PC-based Automation
Expansion components and accessories
SIMATIC IPC CompactFlash

■ Overview
Rugged systems are required when using PCs in industrial
environments to ensure minimal production standstill times.
SIMATIC IPCs have been developed precisely for this purpose.
One possibility for enhancing the industrial compatibility and
system availability of the SIMATIC IPC is to use SIMATIC IPC
CompactFlash instead of hard disk drives. These have been
system-tested with the respective SIMATIC IPC.
SIMATIC IPC CompactFlash can be ordered as a hardware
option through SIMATIC IPC Configurator or as an accessory.
Depending on the application, cards are available with a storage
capacity ranging from 2 GB to 16 GB.

■ Ordering data

Order No.

SIMATIC IPC CompactFlash
• 2 GB
• 4 GB
• 8 GB
• 16 GB

6ES7648-2BF02-0XF0
6ES7648-2BF02-0XG0
6ES7648-2BF02-0XH0
6ES7648-2BF02-0XJ0

SIMATIC IPC CFast
• 2 GB
• 4 GB
• 8 GB
• 16 GB

6ES7648-2BF10-0XF0
6ES7648-2BF10-0XG0
6ES7648-2BF10-0XH0
6ES7648-2BF10-0XJ0

The SIMATIC IPC CFast memory cards are readily replaceable
mass storage units for SIMATIC IPC427D and IPC477D. They
are connected via a SATA interface.
As a result of the different interface, the SIMATIC IPC CFast
memory cards are not compatible with the SIMATIC IPC
CompactFlash memory cards.

SIMATIC IPC USB FlashDrive

■ Overview

■ Technical specifications
SIMATIC IPC USB FlashDrive
SIMATIC IPC Service USB FlashDrive

The SIMATIC IPC USB FlashDrive is the ideal mobile storage
medium for industrial applications.
Thanks to the rugged and ultra-compact construction in a metal
enclosure, fast data transfer (USB 2.0) and the high memory
capacity of 8 GB, the USB FlashDrive is ideally suited for use in
industrial applications.
It replaces diskettes, CD and DVD read/write media as data
memory. Thanks to its high access speed, it is also ideal for tools
that are not to be installed on the computer ("portable apps").
In addition, it can be set up ready to boot using
SIMATIC PC BIOS-Manager. There is an option of expanding
the USB FlashDrive set up in this way into a "tool stick" using
SIMATIC IPC Image & Partition Creator.
The SIMATIC IPC SERVICE USB FlashDrive is the perfect tool for
backup and restoring. With the pre-installed SIMATIC IPC Image
& Partition Creator V3.1, it is immediately ready to use.

Supported operating systems

Windows 2000/XP/Vista/Windows 7/
Windows Server 2003/2008

Capacity

8 GB

Approvals

CE Industry

Temperature
• During operation
• Storage

+5 ... +55 °C
-40 ... +70 °C

Device dimensions (L x W x H) in mm

59.1 x 16.7 x 7

Weight, approx.

12 g

■ Ordering data

5

Order No.

SIMATIC IPC USB FlashDrive
8 GB (SLC), USB 2.0,
metal enclosure, boot capability,
SIMATIC IPC BIOS Manager V3.2
preinstalled for SIMATIC IPC:
Rack PC, Box PC, Panel PC and for
SIMATIC PG

6ES7648-0DC50-0AA0

SIMATIC IPC Service USB
FlashDrive
8 GB (SLC), USB 2.0,
metal enclosure, boot capability,
SIMATIC IPC Image & Partition
Creator V3.2 and SIMATIC IPC BIOS
Manager V3.2 (Win PE) preinstalled,
including CD

6AV7672-8JD01-0AA0

Siemens ST 80 / ST PC · 2013

5/155

© Siemens AG 2013

PC-based Automation
Expansion components and accessories
PC I/O

■ Overview

The PC IO expansion extends the rugged use of the
SIMATIC HMI IPC427C at the machine level.
You can find further information under
Industrial PC -> SIMATIC PC -> SIMATIC Box PC.
The I/O expansion enables and supplements the use of the
SIMATIC HMI IPC427C with:
• Extremely compact dimensions
(262 mm wide, 134 mm high, depth from 47 mm)
• High system availability (rugged and maintenance-free, since
without rotating parts, for example)
• Maximum flexibility
The PC IO expansion comprises:
• Base module with encoder/counter functionality, PCI104
interface to the HOST system and communication interfaces
to the I/O modules
• Digital and analog I/O modules that are managed by the basic
module
• Mechanical installation components
A selection guide with material list for your requirements can be
found at:
http://www.siemens.com/simatic-pc/pc-io-selection

5

Module

Description

PC IO Base 400
(base module)

• PCI104 interface to host
• 4 encoder inputs, can also be used
as counters if required
• 4 digital inputs
• Management of encoder inputs
and associated counters and up to
four I/O modules over separate
communication interfaces
• Power supply distribution
for 4 encoders

PC IO MOD Digital 010
(digital I/O module 0)

• 24 binary 24 V inputs
• 16 binary 24 V outputs

PC IO MOD Analog 020
(analog I/O module 0)

• 8 analog inputs, 12 bits,
0 to 5 V, 0 to 10 V ±5 V, ±10 V
• 8 analog outputs, 16 bits, ±10V
• 4 Pt100 connections, 2-wire

PC IO KIT 040
(encoder expansion rack)

For expanding a SIMATIC Microbox
PC 420/427B/IPC427C.
Connection unit for:
• 4 encoder inputs
• 4 digital inputs
• Encoder voltage supply

PC IO KIT 030
(I/O expansion rack)

Expansion rack to hold
• max. 2 I/O modules in the
Microbox PC 42x system

■ Technical specifications
Electrical data
Supply voltages and current consumption
Parameters

Value

Power supply to base module

Via PCI-104 interface:
3.3 V DC and 5 V DC

Encoder supply voltage infeed

24 V DC

Current consumption of encoder
inputs and counters

0.3 A per encoder

Power supply to digital I/O module 0

24 V DC

Current consumption of digital I/O
module 0, max. approx.

4A

Power supply to analog I/O module 0

5 V DC from Base 400

Current consumption of analog I/O
module 0, max. approx.

5/156

Siemens ST 80 / ST PC · 2013

For expanding a
SIMATIC Microbox
PC 420/427B/IPC427C.

© Siemens AG 2013

PC-based Automation
Expansion components and accessories
PC I/O

■ Technical specifications (continued)
Digital I/O module 0: Digital outputs

Counters and encoder inputs
Parameters

Value

Parameters

Value

Number of counters or encoder inputs
on the base module

4

Number of outputs

16,
Organized in 4 output groups

Input signal from encoder

RS 422
32 bits

Cable length
(without lightning protection element)

max. 30 m

Counting depth
Encoder input counting frequency

≤ 2 MHz

Output voltage

24 V DC

Output current:
• Per output group
• Total per digital I/O module 0

1 A max.
4 A max.

Switching rate

≤ 2 kHz

Switching type

Current sourcing

Sampling time for timer or pulse-width
measurement

1 MHz or 4 MHz

Gate time for frequency measurement

Adjustable in the following stages:
8 µs, 32 µs, 128 µs, 512 µs,
2048 µs, 8192 µs, 16384 µs,
32768 µs, 131072 µs, 262144 µs,
524288 µs, 1048576 µs,
2097152 µs, 4194304 µs,
8388608 µs, 16777216 µs

Output delay:
Internal transmission delay

16 µs

Isolation

No

Protected against polarity reversal

No

Register output to driver output
(load-dependent):
• 0 → 1 signal
• 1 → 0 signal
(with a digital input connected)

Base module: Digital inputs

Isolation:
Yes

Parameters

Value

Number of digital inputs

4

For communication between the
base module and the outputs of
digital I/O module 0

Cable length
(without lightning protection element)

max. 30 m

Isolation test voltage

500 V DC
No, one electrical circuit

Input voltage

24 V DC

Between the individual inputs/outputs
of digital I/O module 0

Input current

Approx. 2 mA

Short-circuit protection of the output
drivers

Threshold on

Time constant of input filter

0.01 ms

Isolation

No

Digital inputs on base module

max. 30 µs
max. 130 µs

Typ. 9 A max. 11 A electronically
pulsing
In order to comply with UL requirements, the user must limit the input
current to 4 A.

Digital I/O module 0: Digital inputs:

Use NEC Class 2 current source

Parameters

Value

Excess temperature shutdown

Above 150 °C

Number of digital inputs

24

Overvoltage protection

Cable length
(without lightning protection element)

max. 30 m

Typ. 47 V
max. 52 V

24 V DC

Status after POWER ON and
after RESET

High resistance

Input voltage
Input current

Approx. 2 mA

Time constant of input filter:
• Inputs 0 … 7
• Inputs 8 … 23
• Inputs 8 and 9 also designed as
high-speed inputs
(parallel to 1 ms path)

0.1 ms
1 ms
0.01 ms

Isolation
For communication between the base
module and the inputs of digital I/O
module 0

Yes

Isolation test voltage

500 V DC

Between the individual inputs/outputs
of digital I/O module 0

No, one electrical circuit

Siemens ST 80 / ST PC · 2013

5/157

5

© Siemens AG 2013

PC-based Automation
Expansion components and accessories
PC I/O

■ Technical specifications (continued)
Analog I/O module
Analog I/O module 0: Analog outputs

Analog I/O module 0: Analog inputs
Parameters

Value

Parameters

Value

Number of analog inputs

8

Number of analog outputs

8

Shielded cable length

max. 30 m

Type

Single-ended

Voltage ranges

0…5V
0 … 10 V
±5 V
±10 V

Shielded cable length

max. 30 m

Voltage range

±10 V

Load current

2 mA max.

max. 15 V, continuous

Resolution

16 bits (including sign)

Accuracy

0.5 %

Conversion time

max. 200 µs per channel

Output value after POWER ON and
after RESET

0V

Permissible input voltage
against analog ground
Impedance

> 10 kOhms

Input type

Single-ended

Resolution

12 bits (including sign)

Repeatability

10 bits (including sign)

Input filters

No

Conversion time

max. 200 µs per channel

Configuration cycle time
for analog-to-digital conversion:
• With one analog input
• With 4 analog inputs
• With 8 analog inputs

Without Pt100

With Pt100

50 ... 100 µs
200 ... 400 µs
400 ... 800 µs

50 ... 200 µs
200 ... 500 µs
400 ... 1000 µs

Isolation

No

Analog I/O module: Pt100 inputs

5

Parameters

Value

Number of external Pt100 inputs

4

Type

Two-wire measurement

Dynamic response

The mean value is constantly available and is updated approximately
every 6 ms.

Isolation

No

5/158

Siemens ST 80 / ST PC · 2013

Configuration cycle time for
digital-to-analog conversion1):
• With one analog input
• With 4 analog inputs
• With 8 analog inputs

100 ... 200 µs
400 ... 800 µs
800 ... 1600 µs

Short-circuit protection

No

Isolation

No

1)

The times also depend on the software response time
(interrupt response time or polling times).

© Siemens AG 2013

PC-based Automation
Expansion components and accessories
PC I/O

■ Technical specifications (continued)
Environmental requirements for installation in Microbox PC 42x
Degree of protection to EN 60529
(front/rear)

IP20

Protection class

Protection class I acc. to VDE 0106 Part 1 (IEC 536)

Vibration load during operation

Devices without hard disk:
Frequency

Acceleration

Displacement

Cycles per axis

Octaves/min

10 to 58 Hz

-

0.075 mm

10

1

58 to 200 Hz

9.8 m/s2

-

10

1

Displacement

Cycles per axis

Octaves/min

acc. to IEC 60068-2-6, test Fc
Devices with hard disk: Wall mounting
Frequency

Acceleration

10 to 58 Hz

0.035 mm

10

1

58 to 200 Hz

4.9 m/s2

10

1

Standard rail: No mechanical excitation permitted
Shock loading during operation

Devices without hard disk:
Acceleration

Shock duration

150 m/s2

11 ms

acc. to IEC 60068-2-27, test Ea
3 in both pos. and neg. direction per axis, half-sine
Devices with hard disk: Wall mounting:
Acceleration

Shock duration

50 m/s2

30 ms

Standard rail: No mechanical excitation permitted
Electromagnetic compatibility (EMC)
• Emitted interference

• Immunity to conducted interference
on the supply lines

• Immunity to conducted interference
on the unshielded supply lines

• Immunity to conducted interference
on the shielded supply lines
• Immunity to static discharge
• Immunity to radio frequ. interference
• Immunity to high-frequ. current feed

EN 55022 Class B
In order to comply with Class B, a 230 V AC power supply unit must be used which meets the requirements
of EN 55022 Class B (e.g. "SITOP modular 5 A", type No.: 6EP1333-3BA00).
• ±2 kV (IEC 61000-4-4, Burst)
• ±1 kV (IEC 61000-4-5, symm. surge, length > 30 m)
with lightning protection element (e.g. from Dehn, type "Blitzductor BVT AD24", type No.: 918402)
• ±2 kV (IEC 61000-4-5, unsymm. surge, length > 30 m)
with lightning protection element (e.g. from Dehn, type "Blitzductor BVT AD24", type No.: 918402)
• ±2 kV (IEC 61000-4-4, burst)
• ±1 kV (IEC 61000-4-5, symm. surge, length > 30 m)
with lightning protection element (e.g. from Dehn, type "Blitzductor BVT AD24", type No.: 918402)
• ±2 kV (IEC 61000-4-5, unsymm. surge) Length > 30 m)
with lightning protection element (e.g. from Dehn, type "Blitzductor BVT AD24", type No.: 918402)
• ±2 kV (IEC 61000-4-4, burst)
• ±1 kV (IEC 61000-4-5, surge symm., length > 30 m)
• ±2 kV (IEC 61000-4-5, surge unsymm., length > 30 m)
• ±6 kV, contact discharge (IEC 61000-4-2)
• ±8 kV, air discharge (IEC 61000-4-2)
• 10 V/m 80 % AM; 80 MHz to 1 GHz (IEC 61000-4-3);
• 10 V/m 80 % AM; 1.4 GHz to 2 GHz (IEC 61000-4-3)
• 10 V 80 % AM, 9 kHz to 80 MHz (IEC 61000-4-6)

Ambient temperature during operation

• 0 to 50 ºC with Flash drive (horizontal; preferred mounting position)
• 0 to 45 ºC with Flash drive (vertical)
• 5 to 40 ºC with hard disk (horizontal and vertical)

Ambient temperature during storage
and transport

-20 °C … +60 °C

Moist heat

30 °C/85 % (IEC 60068-2-78, Test Cab)

5

Approvals
Safety regulations

IEC/EN 60950-1

CE marking

• EC Directive 89/336/EEC (EMC Directive)
• Use in industry:
• Applications in residential areas, business and trade environments as well as in workshops:
- Emitted interference: EN 61000-6-4
- Noise immunity: EN 61000-6-2
• Applications in residential areas, business and trade environments as well as in workshops:
- Emitted interference: EN 61000-6-3
- Noise immunity: EN 61000-6-1

Dimensions and weights
Equipment dimensions (in mm)

•
•
•
•
•

Width x height: 262 x 134
Depth of basic unit: 47
Depth of basic unit above rail: 52
Additional depth per encoder expansion rack (Kit 040): 17
Additional depth per I/O expansion rack (Kit 030): 22

Siemens ST 80 / ST PC · 2013

5/159

© Siemens AG 2013

PC-based Automation
Expansion components and accessories
PC I/O

■ Ordering data
PC IO Base 400

Order No.
6ES7648-2CE20-0AA0

PCI104 module for connecting
up to 4 PC IO MOD xxx 010/020,
with 4 encoder interfaces and 4 DI
incl. fixing accessories (base
module with fixing accessories)

Order No.
PC IO KIT 030
I/O module expansion rack for
Microbox PC 420/427B/IPC427C
for installing up to 2 I/O modules,
including fixing accessories and a
cover plate

PC IO MOD Digital 010
Digital I/O module
with 24 DI and 16 DO,
incl. connecting cable to
PC IO Base 400 and
mating connector

6ES7648-2CE40-0BA0

PC IO KIT 040

PC IO MOD Analog 020

6ES7648-2CE40-0CA0

Encoder expansion rack for
Microbox PC 420/427B/IPC427C
for contacting the encoder
interfaces and DIs of the
PC IO Base 400,
including fixing accessories

Analog I/O module with 8 AI,
8 AO and 4 PT100,
incl. connecting cable to
PC IO Base 400,
mating connector and shield clamp

5

5/160

6ES7648-1AA20-0XF0

Siemens ST 80 / ST PC · 2013

6ES7648-1AA20-0XE0

© Siemens AG 2013

PC-based Automation
Expansion components and accessories
SIMATIC Panel PC Remote Kit

■ Overview

■ Ordering data

Order No.

SIMATIC Panel PC Remote Kit
24 V DC, 5 m

6AV7671-1EA00-5AA1

24 V DC, 10 m

6AV7671-1EA01-0AA1

24 V DC, 15 m

6AV7671-1EA01-5AA1

24 V DC, 20 m

6AV7671-1EA02-0AA1

24 V DC, 30 m

6AV7671-1EA03-0AA1

100/240 V AC, 5 m

6AV7671-1EA10-5AA1

100/240 V AC, 10 m

6AV7671-1EA11-0AA1

100/240 V AC, 15 m

6AV7671-1EA11-5AA1

100/240 V AC, 20 m

6AV7671-1EA12-0AA1

100/240 V AC, 30 m

6AV7671-1EA13-0AA1

Accessories
Power supply cable

The Remote Kit makes it possible to separate the Panel PC 677B
operator control unit from the computer unit and install them up
to 30 m apart.

■ Technical specifications
SIMATIC Panel PC Remote Kit

Europe: D/F/NL/E/B/A/S/FIN 1)

6ES7900-1AA00-0XA0

United Kingdom

6ES7900-1BA00-0XA0

Switzerland

6ES7900-1CA00-0XA0

USA

6ES7900-1DA00-0XA0

Italy

6ES7900-1EA00-0XA0

China

6ES7900-1FA00-0XA0

Sub-components
of the Remote Kit
(only available individually
as spare parts)

Design

Subsequent installation on the
Panel PC 677B operator control unit

Supported operator control units

All Panel PC 677B operator control
units:
• 12" Touch/Key
• 15" Touch/Key
• 17" Touch
• 19" Touch

24 V DC remote module
with fixing accessories

6AV7671-1EX01-0AD0

110/240 V AC remote module
with fixing accessories

6AV7671-1EX01-0BD0

USB amplifier/CAT6 converter

6AV7671-1EX02-0AB0

•
•
•
•
•

5 m cable set
(DVI, USB standard cable)

6AV7671-1EX10-5AA0

10 m cable set (DVI, Cat 6 cable)

6AV7671-1EX11-0AA0

15 m cable set (DVI, Cat 6 cable)

6AV7671-1EX11-5AA0

20 m cable set (DVI, Cat 6 cable)

6AV7671-1EX12-0AA0

30 m cable set (DVI, Cat 6 cable)

6AV7671-1EX13-0AA0

Cable sets

Front panel functionality

5m
10 m
15 m
20 m
30 m

As centralized installation with the
following constraint in respect of
USB functionality:
• Distance 5 m: USB 2.0,
and only one external 2.0 Hub
• Distance > 5 m: USB 1.1,
and only one external 1.1 Hub

External ports

2 additional USB ports on the
remote module (on the rear of the
remote operator control unit)

Power supply

24 V DC; 20.4 ... 28.8 V DC or
110 ... 240 V AC; 50/60 Hz

Approvals

CE, cULus (UL 508)

Scope of supply

• Remote module
• Cable set
• Mounting accessories for the
PC 677B computer unit
• European power supply cable
(with the AC option)

1)

5

A European power supply cable is included in the scope of delivery of the
AC (100-240 V) version of the Remote Kit.

Siemens ST 80 / ST PC · 2013

5/161

© Siemens AG 2013

PC-based Automation
Expansion components and accessories
SIMATIC Panel PC Remote Kit

■ Dimensional drawings
All dimensions in mm. For mounting cut-out see technical specifications.

Front dimensions

H

400
483
483

310
310
400

483
483

310
355

W+1

H+1

D

368
450
450

290
290
380

95
93
102

450
450

290
321*

77
96

H

W

10.5
W

Touch panels
12"
15"
19"
Key Panels
12"
15"

Installation cutout
W+1 (cutout)

H+1 (cutout)

Touch panels
12"
15"
19"
Key Panels
12"
15"

* In addition: two recesses 25 x 5 mm on the top side
for keyboard slide-in label channels

5

5/162

Siemens ST 80 / ST PC · 2013

G_ST80_XX_00267

D

© Siemens AG 2013

PC-based Automation
Expansion components and accessories
SIMATIC IPC Image & Partition Creator

■ Overview

■ Ordering data

Order No.

SIMATIC IPC Image & Partition
Creator V3.3

Can be ordered using the
SIMATIC IPC Configurator

SIMATIC IPC Image & Partition
Creator V3.3
Software tool for very easy preventive data backup and efficient partition management on SIMATIC IPCs

6ES7648-6AA03-3YA0

Note:
SIMATIC IPC Image & Partition Creator is also available together
with the SIMATIC IPC BIOS Manager preinstalled with the
SIMATIC IPC Service USB FlashDrive.

SIMATIC IPC Image & Partition Creator is the software tool for
easy, preventive back-up and restoring of hard disk contents
(images of individual partitions or complete hard disks). This
software can be ordered through the Configurator for the
SIMATIC IPCs, or separately with single license.
• Can run on all SIMATIC IPCs, regardless of the computer
configuration
• Direct starting from the CD possible (no installation required)
• Complete backup by means of a mouse double-click with
"1ClickImage" (must be installed)
• Menu-driven creation of a bootable USB flash drive as an
alternative start medium from which SIMATIC IPC Image &
Partition Creator can be started.
• Independent of the operating system thanks to ability to start
from the bootable SIMATIC IPC Image & Partition Creator CD
or bootable USB flash drive with Image & Partition Creator

5

Siemens ST 80 / ST PC · 2013

5/163

© Siemens AG 2013

PC-based Automation
Expansion components and accessories
SIMATIC IPC DiagMonitor

■ Overview

■ Ordering data

Can be ordered using the
SIMATIC IPC Configurator

SIMATIC IPC DiagMonitor V4.4

6ES7648-6CA04-4YX0

Software tool for monitoring the
SIMATIC IPC,
incl. manual on CD ROM
(English, German), single license

SIMATIC IPC DiagMonitor: Intelligent and comprehensive
diagnostics for the SIMATIC IPC – local and remote.
The SIMATIC IPC DiagMonitor software for monitoring and
remote signaling detects possible hardware and software faults
at an early stage. It monitors, signals and visualizes the
operating statuses of the SIMATIC IPC both locally and remotely.

5

DiagMonitor V4.4 can run on the following SIMATIC IPCs:
• Microbox PC 427B
• Box PC 627B/827B
• Rack PC IL 43 / 547B / 647B / 847B
• Panel PC 477B/577B/677B
• IPC427C / IPC627C / IPC827C
• IPC547C / IPC647C / IPC847C
• HMI IPC477C / HMI IPC477C PRO / HMI IPC577C /
HMI IPC677C
• IPC227D / IPC277D / IPC427D / IPC477D / IPC547D
The software can be ordered as:
• Individual product from stock (e.g. for server applications on
third-party PCs or immediate integration in new systems) or
• Option ordered according to the SIMATIC IPC configurator
(Internet, Mall).
(DiagMonitor V3.1 is used with SIMATIC Microbox PC 420/427B,
Box PC 627/627B, Rack PC IL 43/840/847B, Panel PC 477/477B/
677/677B/877 and can be ordered directly via the PC configurator or as an individual product.)

5/164

Siemens ST 80 / ST PC · 2013

Order No.

SIMATIC IPC DiagMonitor V4.4

© Siemens AG 2013

PC-based Automation
Expansion components and accessories
SIMATIC IPC Remote Manager

■ Overview
Remote diagnostics and access without on-site support
• Troubleshooting
• No operating system required
• BIOS and program updates
• Remote filling (supports ISO image > 2 GB)
• Configurable time-out

Control

Production

Administrator

Without AMT

AMT clients
Central service

Resource management

• Easy access on SIMATIC IPC
• No additional hardware (e.g. KVM switch)
• Over secure connections

• Saves electricity cost
• Efficient use of production time

G_ST80_XX_00443

With AMT

SIMATIC IPC Remote Manager
Efficient remote maintenance and management of
SIMATIC IPCs.
With the SIMATIC IPC Remote Manager you can use functions
of the Intel active management technology (Intel AMT) for
SIMATIC IPCs. Intel AMT is used for remote management of
PCs.

5

Intel AMT offers a range of functions, such as:
• Remote reboot
• IDE redirection
• Keyboard video mouse redirection
• Power on / off / reset, and
• an integrated Web server.
http://support.automation.siemens.com/WW/view/en/56230140

■ Ordering data
SIMATIC IPC Remote Manager
V1.2
Software tool for remote
maintenance and management
of SIMATIC IPC,
incl. manual on CD-ROM
(English, German), single license

Order No.
6ES7648-6EA01-2YA0

Siemens ST 80 / ST PC · 2013

5/165

© Siemens AG 2013

PC-based Automation
Expansion components and accessories
SIMATIC IPC BIOS Manager

■ Overview

■ Ordering data
SIMATIC IPC BIOS Manager
Software tool for the
management and processing of
SIMATIC IPC BIOS data

Order No.
available as a download
from Customer Support
http://support.automation.siemens.com/WW/
view/en/58512643

Note:
SIMATIC IPC BIOS Manager is also available together with the
SIMATIC IPC USB FlashDrive and IPC Service USB FlashDrive.

The SIMATIC IPC BIOS Manager V3.3 (WinPE) is a software tool
for the management and processing of SIMATIC IPC BIOS data.
The tool is obtained by downloading it from the
Service & Support web pages of Industry Automation & Drive
Technologies using the Automation Value Card.
http://support.automation.siemens.com/WW/view/en/58512643

5

5/166

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
Input and output devices
SIMATIC PC keyboard

■ Overview

■ Ordering data

The original SIMATIC PC keyboard is the ideal input medium for
your SIMATIC PC. It combines the convenience of an office
keyboard with the ruggedness of an industrial device. The
SIMATIC PC keyboard is available with a USB connection and
German/international layout.

SIMATIC PC keyboard

Order No.
6ES7648-0CB00-0YA0

German/international,
USB connection
incl. USB-PS2 adapter

■ Technical specifications
SIMATIC PC keyboard
Description

SIMATIC PC keyboard

Layout

MF2, 105 keys,
German/international

Dimensions (L x W x H) in mm

470 x 195 x 44

Weight, approx.

1400 g

Connecting cable

Length 1.75 m, USB plug

Temperature
• During operation
• Storage

0 ... +50 °C
-20 ... +60 °C

Current consumption

-

Current delivery

-

Transmission rate

-

Approvals

FCC, cURus, GS, CE, c-tick,
GOST-R

5

Siemens ST 80 / ST PC · 2013

5/167

© Siemens AG 2013

PC-based Automation
Input and output devices
IP65 membrane keyboard, desk version

■ Overview

■ Ordering data

The desktop version of the IP65 membrane keyboard is ideal for
use in industrial areas in which a high degree of protection (IP65)
is required. The keyboard is equipped with a touchpad.

■ Technical specifications
• Color “light-basic”
• MF2/Windows 95 compatible key layout
with 105 short-stroke keys, type Omron
• German or international key layout
• Desktop unit made of polyester
• Mounting plate and base made of metal
• Front membrane made of resistant polyester (150 µm thick)
• 1 million strokes per key
• Y cable with 2 PS/2 connectors with 1.8 m connecting cable
• Weight approx. 1190 g
• Dimensions in mm (W x D x H): 478.6 x 180 x 26
• Licences: UL 1950, CSA C22.2 No. 950
• CE conformity according to EC 89/336
• Degree of protection IP65

Order No.

Standard configuration
IP65 membrane keyboard,
desktop version with touchpad
With PS/2 connector
• German keyboard layout
• International keyboard layout

6GF6710-2AC
6GF6710-2BC

IP65 membrane keyboard, 19" built-in version

■ Overview

5

■ Ordering data

The built-in version of the IP65 membrane keyboard is ideal
for use in industrial areas in which a high degree of protection
(IP65 at the front, IP54 at the rear) is required. The keyboard is
specially designed for installation in 19" cabinets.

■ Technical specifications
• Color “light-basic”
• MF2/Windows 95 compatible key layout with 105 short-stroke
keys, type Omron
• German or international key layout
• Desktop unit made of polyester
• 19“/4HU mounting plate made of metal (1.6 mm thick)
• Front membrane made of resistant polyester (180 µm thick)
• Touchpad or trackball (IP65 version)
• Y cable with 2 PS/2 connectors with 1.8 m connecting cable
• Weight approx. 1480 g
• Dimensions in mm (W x D x H): 482.6 x 177.8 x 42.5
• Licences: UL 1950, CSA C22.2 No. 950
• CE conformity according to EC 89/336
• IP65 protection at the front, IP54 at the rear

5/168

Siemens ST 80 / ST PC · 2013

Order No.

Standard configuration
IP65 membrane keyboard,
19" built-in version
For installation in 19" cabinets
With touchpad
• German keyboard layout
• International keyboard layout

6GF6710-3AE
6GF6710-3BE

With trackball
• German keyboard layout
• International keyboard layout

6GF6710-3BF
6GF6710-3BG

© Siemens AG 2013

PC-based Automation
Input and output devices
19" slide-in keyboard PS/2 with trackball

■ Overview
With its compact design and integrated trackball the new drawout keyboard is suitable in particular for industrial applications
with limited space. This can be, for example, cubicles or mobile
systems.
The draw-out keyboard is supplied in combination with a drawer.

■ Ordering data

Order No.

Standard configuration
19" withdrawable keyboard
With trackball
• German keyboard layout
• International keyboard layout

6GF6710-3BJ
6GF6710-3BK

SIMATIC IPC mouse

■ Overview
Robust mouse for harsh everyday use with a pleasantly coated
slip-free surface, precise BlueTrack technology, three buttons
incl. large scroll wheel, trouble-free cable operation and
symmetrical casing design for right-handed and left-handed
users.
• Interface: USB
• Operating systems: Microsoft Windows® 7, Windows Vista®
and Windows XP (not for Windows XP 64 bit)
• Connection cable: 2 m long, USB plug
• Approvals corresponding to office environment:
- ACA/MED Declaration of Conformity
(Australia and New Zealand)
- ICES-003 report on file (Canada)
- EIP Pollution Control Mark, EPUP (China)
- CE Declaration of Conformity, Safety and EMC
(European Union)
- WEEE (European Union)
- VCCI Certificate (Japan)
- KCC Certificate (Korea)
- GOST Certificate (Russia)
- BSMI Certificate (Taiwan)
- FCC Declaration of Conformity (USA)
- UL and cUL Listed Accessory (USA and Canada)
- CB Scheme Certificate (International)

■ Ordering data

Order No.

SIMATIC IPC mouse
Optical (BlueTrack) wheel mouse,
USB interface
Color
• Anthracite
• White

6ES7648-0BB00-0XA0
6ES7648-0BB00-0XA1

5

Siemens ST 80 / ST PC · 2013

5/169

© Siemens AG 2013

PC-based Automation
SITOP power supplies
SITOP power supplies

■ Overview
The complete SITOP range
In addition to the power supplies, the perfectly coordinated,
complete range offers a unique choice of modules - from those
that protect the 24 V power supply against interference on the
primary and secondary side, right up to those providing
complete protection. Every day, SITOP is used successfully in
innumerable practical applications and protects against plant
downtimes and production outages.
Quick selection and fast delivery
With the SITOP Selection Tool - available in the Internet under
http://www.siemens.com/sitop-selection-tool and in the Industry
Mall – the suitable power supply can be selected quickly and
easily, the selected products can be saved or placed into the
Mall's shopping cart and then ordered there.
We deliver all SITOP standard products from stock to ensure that
you receive the SITOP power supply you selected quickly.
Customized SITOP products
SITOP – reliable 24 V power supply
Efficient operation of a machine or plant requires a reliable,
constant power supply. The quality and reliability of the
SITOP stabilized power supplies ensure high levels of safety
in DC power supply in industrial engineering and building
management systems. They supply a stabilized 24 volts, but
also other output voltages. Even in the case of large input
voltage variations, the output voltage is kept stable with a high
degree of accuracy. This enables the use of primary switchedmode power supplies in many applications for the supply of
sensitive electronic systems - all the way up to loads requiring
high currents.

5

The fan-free power supplies are characterized by their compact
and rugged design, high overload capability, as well as special
energy efficiency. The high efficiency across the entire load
range and the low no-load loss ensure efficient operation. The
large input voltage range and the international approvals mean
that use is possible in almost all supply networks worldwide.

5/170

Siemens ST 80 / ST PC · 2013

Our standard power supplies cannot, of course, satisfy the
requirements of every application. We can design a specific
power supply for your application-specific requirements. You
benefit from the expertise of large-scale production and gain
maximum development security and quality.
Our customer-specific solutions are used today in many sectors
of mechanical engineering, in automation technology, vehicle
electronics, equipment manufacturing, or in industrial instrumentation technology. If your are interested, please contact your
local Siemens office.

© Siemens AG 2013

PC-based Automation
SITOP power supplies
1-phase, 24 V DC/10 A (SITOP PSU100S)
1-phase, 24 V DC/20 A (SITOP PSU100S)

■ 1-phase, 24 V DC/10 A (SITOP PSU100S)

The single-phase power supply for universal use; complies with
EU directive 94/9/EC (ATEX 100a); slim design; with 50 % extra
power for 5 s and 120 % rated power up to 45 °C.

■ Ordering data
SITOP PSU100S 24 V/10 A

Order No.
6EP1334-2BA20

Stabilized power supply
Input: 120/230 V AC
Output: 24 V DC/10 A
SITOP smart 240 W

■ 1-phase, 24 V DC/20 A (SITOP PSU100S)

High-performance, standard power supply for 1-phase
120/230 V AC grids, with automatic range switching;
high overload capability through Extra power with 1.5 times the
rated current for 5 s and continuous 120 % output power up to
+45 °C ambient temperature.

■ Ordering data

Order No.

SITOP PSU100S 20A
Stabilized power supply;
Input: 120/230 V AC,
Output: 24 V DC/20 A

6EP1336-2BA10

6EP1334-2AA01

Stabilized power supply
Input: 120/230 V AC
Output: 24 V DC/10 A
SIPLUS smart 10 A

5

6AG1334-2BA20-4AA0

For medial load
based on 6EP1334-2BA20

Siemens ST 80 / ST PC · 2013

5/171

© Siemens AG 2013

PC-based Automation
SITOP power supplies
3-phase, 24 V DC/10 A (SITOP PSU300S)
3-phase, 24 V DC/20 A (SITOP PSU300S)

■ 3-phase, 24 V DC/10 A (SITOP PSU300S)

High-performance, standard power supply for 3-phase networks
3 AC 400-500 V, high overload capability through Extra power
with 1.5 times the rated current for 5 s and continuous 120 %
output power to +45° C ambient temperature.

■ Ordering data
SITOP smart PSU300S 10 A

Order No.
6EP1434-2BA10

Stabilized power supply;
input: 3 AC 400 … 500 V;
output: 24 V DC/10 A

■ Ordering data
SITOP smart PSU300S 20 A

Order No.
6EP1436-2BA10

Accessories
3RT1900-1SB20

5

5/172

High-performance, standard power supply for 3-phase networks
3 AC 400-500 V, high overload capability through Extra power
with 1.5 times the rated current for 5 s and continuous 120 %
output power to +45° C ambient temperature.

Stabilized power supply
Input: 3 AC 400 ... 500 V
Output: 24 V DC/20 A

Accessories
Device labels

■ 3-phase, 24 V DC/20 A (SITOP PSU300S)

Siemens ST 80 / ST PC · 2013

Device labels

3RT1900-1SB20

© Siemens AG 2013

PC-based Automation
SITOP power supplies
3-phase, 24 V DC/40 A (SITOP PSU300S)

■ 3-phase, 24 V DC/ 40 A (SITOP PSU300S)

■ Ordering data

Order No.

SITOP PSU300S 40 A

6EP1437-2BA20

Stabilized power supply
Input: 3 AC 400 … 500 V
Output: 24 V DC/40 A
Accessories
SITOP PSE202U
redundancy module

6EP1961-3BA21

Input/output: 24 V DC/40 A
suitable for decoupling two SITOP
power supplies with a maximum of
20 A output current
Device labels

3RT1900-1SB20

High-performance, standard power supply for 3-phase networks
3 AC 400-500 V, high overload capability through Extra power
with 1.5 times the rated current for 5 s and continuous 120 %
output power to +45° C ambient temperature.

5

Siemens ST 80 / ST PC · 2013

5/173

© Siemens AG 2013

PC-based Automation
24 V DC uninterruptible power supplies
24 V DC uninterruptible power supplies

■ Overview
Permanently reliable 24 V – even when the power fails:
Uninterruptible power supply
Supply network irregularities in the millisecond range are
compensated for supremely well by all our power supplies.
Large fluctuations or even power failures, however, require
special measures: The buffer module (see SITOP add-on
modules) ensures optimal protection in the case of brief power
failures up to 3 seconds.

Longer power failures into the minute range can be bridged with
the new maintenance-free SITOP UPS500 with capacitor
technology.
The DC UPS modules with battery modules secure continued
operation for hours! Both DC UPS systems can be integrated
simply into PC-based automation solutions using a free software
tool.

Backup module

SITOP DC UPS module

SITOP UPS500

Expansion module with electrolyte
capacitors for bridging temporary power
failures. Can be combined with SITOP
modular.

DC UPS module with maintenance-free
lead-gel batteries for energy storage.
Bridging of power failures even for hours.

DC UPS with high-capacity double-layer
capacitors. Bridging of power failures for
severyl minutes.

Selection criteria:

Selection criteria:

Selection criteria:

Low-cost protection against power
failures for max. 3 seconds
Supports the power supply unit when there
is a temporary increased power demand
High load current up to 40 A

The 24 V power supply is maintained
for a long time, e.g. in order to continue
processes.
High load current up to 40 A

Backup data and closing of applications
within minutes.
Absolutely maintenance-free
High ambient temperatures up to 60°C
No ventilation is required since no gas
is emitted
For distributed applications without
control cabinet

G_ST80_XX_00486

5

The SITOP UPS500 is completely maintenance-free because
it saves energy in high-capacitance double-layer capacitors.
These have a long service life even in high temperatures, and do
not need to be replaced. The installation location does not have
to be ventilated because no gas is emitted. The innovative
DC UPS buffers 24 V into the minutes range and makes it
possible to back up data and to shut down PC-based applications (e.g. with SIMATIC PC) safely.

The SITOP UPS500S is designed for installing on a standard
mounting rail and it can be modularly expanded to extend the
backup time. The UPS500P in degree of protection IP65 is
suitable for distributed use.
The SITOP DC UPS with battery modules using lead gel
batteries up to 12 Ah enables process operation to continue for
hours. The availability, battery supply line, aging status, and
charge status are permanently monitored.
The integral battery management system ensures optimal
charging of the battery modules and a long service life.

5/174

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
24 V DC uninterruptible power supplies
24 V DC uninterruptible power supplies

■ Overview (continued)
SITOP power supply

Load

DC UPS module with battery module

Messages
- Mains or buffer operation
- Buffer ready or alarm
Charging status >85 % or <85 %
via USB interface or floating relay contacts

SITOP UPS500S basic unit 15 A
maintanance-free with capacitor, optionally with
expansion module as additional energy storage
24 V DC

AC or 3 AC

G_KT01_EN_00357

24 V DC

USB interface for data exchange with
industrial PC

5
DC UPS software
The uninterruptible DC power supplies are optionally available
with USB interface or serial interface. All relevant messages
about the status of the uninterruptible DC power supply can be
transferred to a PC (e.g. SIMATIC IPC) via this interface.
SITOP DC UPS software provides the user with a very easy to
use software tool with which the signals sent by the uninterruptible DC power supply can be further processed on the PC.
In monitoring mode, the statuses of the uninterruptible DC power
supply are visualized on the PC.
Safe shutdown in the event of a power failure and automatic PC
restart are supported. It is also possible to freely define
responses to the different operating states of the uninterruptible
DC power supply, so that extremely flexible integration into a
wide variety of applications is possible.
The software runs under the Windows 2000, Windows XP,
Windows Vista and Windows 7 operating systems. It is available
as downloadable freeware on the SITOP homepage.
Monitoring and configuration window of software V3 for SITOP DC UPS

http://www.siemens.com/sitop-ups

■ More information
You can select the appropriate power supply quickly and easily
using the SITOP Selection Tool:
http://www.siemens.com/sitop-selection-tool

Siemens ST 80 / ST PC · 2013

5/175

© Siemens AG 2013

PC-based Automation
DC UPS with capacitors
DC UPS with capacitors

■ Overview
Uninterruptible power supplies normally store the electrical
energy in lead-acid batteries. Temperatures such as those
prevalent in control cabinets considerably shorten the service
life of the battery, however, and the batteries must be replaced
on a regular basis – annually at an ambient temperature of 40 °C,
for example. The innovative SITOP UPS500, however, is based
on absolutely maintenance-free capacitors with a long service
life. Even at temperatures of 50 °C they still have more than 80%
of their capacity after 8 years. This means that the energy
storage unit does not have to be replaced. Because the capacitors do not emit any gas, the control cabinet does not have to be
ventilated.
Another advantage is the significantly shorter charging times of
the double-layer capacitors, which ensure that the buffer is
ready very quickly after loss of power.
The SITOP UPS500P IP65 version has capacitors for 5 or 10 kW
and supplies up to 7 A output current. The oblong metal
enclosure is also suitable for installing on support arm systems.
Selection table SITOP UPS500
(optional with SITOP UPS501S expansion module)
and mains buffering times
Buffering and charging times
UPS500P

SITOP UPS500S/501S configurations

5

Basic unit

2.5 kW

5 kW

2.5 kW

5 kW

2.5 kW

5 kW

2.5 kW

5 kW

5 kW

10 kW

Expansion
modules

-

-

1 × 5 kW

1 × 5 kW

2 × 5 kW

2 × 5 kW

3 × 5 kW

3 × 5 kW

-

-

Total energy

2.5 kW

5 kW

7.5 kW

10 kW

12.5 kW

15 kW

17.5 kW

20 kW

5 kW

10 kW

Load current

Buffer times

0.5 A

134 s

236 s

390 s

478 s

632 s

748 s

851 s

1007 s

284 s

647 s

0.8 A

90 s

167 s

266 s

346 s

440 s

527 s

580 s

706 s

190 s

435 s

1A

75 s

138 s

219 s

296 s

365 s

414 s

490 s

572 s

153 s

351 s

2A

38 s

76 s

122 s

156 s

203 s

230 s

265 s

306 s

80 s

152 s

3A

26 s

52 s

82 s

106 s

136 s

159 s

186 s

213 s

53 s

108 s

4A

19 s

39 s

61 s

81 s

101 s

120 s

139 s

160 s

40 s

84 s

5A

15 s

31 s

49 s

65 s

81 s

95 s

111 s

130 s

30 s

68 s

6A

12 s

26 s

40 s

55 s

67 s

80 s

94 s

106 s

25 s

57 s

7A

10 s

21 s

34 s

47 s

58 s

69 s

81 s

82 s

21 s

49 s

8A

8s

18 s

29 s

40 s

50 s

59 s

69 s

79 s

-

-

10 A

6s

15 s

23 s

32 s

39 s

47 s

54 s

62 s

-

-

12 A

4s

12 s

19 s

26 s

32 s

38 s

44 s

52 s

-

-

15 A

3s

9s

14 s

20 s

25 s

30 s

35 s

40 s

-

-

Charging
current

Charging times

2A

54 s

120 s

158 s

223 s

263 s

318 s

355 s

417 s

130 s

360 s

1A

110 s

205 s

311 s

425 s

503 s

625 s

695 s

816 s

-

-

Important information for selecting the energy storage units:
When the mains buffering times were determined, the discharge
period of new or non-aged, completely charged capacitors was
used as a basis. At a continuous ambient temperature of +50 °C,

■ More information
You can select the appropriate power supply quickly and easily
using the SITOP Selection Tool:
http://www.siemens.com/sitop-selection-tool

5/176

Siemens ST 80 / ST PC · 2013

a loss of capacity of approx. 20% must be considered after a
service life of 8 years.

© Siemens AG 2013

PC-based Automation
DC UPS with capacitors
SITOP UPS500S

■ Overview

Basic device 15 A, SITOP UPS500S
• Compact design, only 120 mm wide
• Two versions with integrated energy storage units:
2.5 kW or 5 kW
• Can be expanded easily using a user-friendly plug-in system
with the expansion module 5 kW
• Absolutely uninterruptible bridging of power failures, as soon
as the DC UPS input voltage falls below the value set by the
DIP switches
• High level of safety and availability through monitoring of
operational readiness, and monitoring of the capacitor charge
(message "> 85% charged")
• Support for automatic warm restart of industrial PCs through
selectable shutdown characteristics
• With USB interface

Maintenance-free power supply in the form of a combination of a basic
module and an expansion module

SITOP UPS501S expansion module
• Additional energy storage (5 kW)
• Up to 3 expansion modules can be connected to a
SITOP UPS500S to extend the buffer times
• Compact design, only 70 mm wide
• Can be easily connected to SITOP UPS500S
via a user-friendly plug-in system
• Complete with balancing and safety circuits
• Can be snapped onto standard mounting rail
EN 60715 35x7.5/15
• Dimensions (W x H x D) in mm: Approx. 70 x 125 x 125
• Weight: Approx. 0.7 kg

■ Ordering data

Order No.

SITOP UPS500S
DC UPS basic device 15 A with
• 2.5 kW
• 5 kW

6EP1933-2EC41
6EP1933-2EC51

SITOP UPS501S
Expansion module 5 kW for
connecting to the basic device

6EP1935-5PG01

Accessories
Device labels

3RT1900-1SB20

Siemens ST 80 / ST PC · 2013

5/177

5

© Siemens AG 2013

PC-based Automation
DC UPS with capacitors
SITOP UPS500P

■ Overview

■ Ordering data

Order No.

SITOP UPS500P
DC UPS basic device 7 A with
• 5 kW
• 10 kW
Connector set
consisting of connector for input and
output and an assembled USB cable
(2 m in length)

Basic device 7 A, IP65, SITOP UPS500P
• Compact design, degree of protection IP65
• For distributed use, e.g. on support arms
• Integrated energy storage: 5 kW or 10 kW
• Ambient temperature range for operation: 0 to +55 °C
• High degree of efficiency 96.9% or low power loss, approx.
6 W with 7 A load current
• USB interface
• Indication of the operating states normal operation, buffer
mode, alarm message "Buffer not ready" and indication of the
capacitor charge > 85%

5

5/178

Siemens ST 80 / ST PC · 2013

6EP1933-2NC01
6EP1933-2NC11
6EP1975-2ES00

© Siemens AG 2013

PC-based Automation
DC UPS with battery modules
DC UPS with battery modules

■ Overview
By combining a DC UPS module with at least one 24 V battery
module and a SITOP power supply unit, longer power failures
can be bridged without any interruption.
The combination is used for example in machine-tool building, in
the textile industry, on all types of production lines and filling
plants, and in conjunction with 24 V industrial PCs. This prevents
the negative effects which often result from power failures.
DC UPS modules: 6 A, 15 A, 40 A

Battery modules:
• 1.2 Ah (contains lead-acid batteries with corrosion-resistant
lead-calcium high-performance grid plates and fiberglass
mat)
• 3.2 Ah (contains lead-acid batteries with corrosion-resistant
lead-calcium high-performance grid plates and fiberglass
mat)
• 7 Ah (contains lead-acid batteries with corrosion-resistant
lead-calcium high-performance grid plates and fiberglass
mat)
• 12 Ah (contains lead-acid batteries with corrosion-resistant
lead-calcium high-performance grid plates and fiberglass
mat)
• 2.5 Ah (contains "high-temperature battery" type pure lead)

Selection table for battery modules and mains buffering times
Load current

Battery module 1.2 Ah
(6EP1935-6MC01)

Battery module 3.2 Ah
(6EP1935-6MD11)

Battery module 7 Ah
(6EP1935-6ME21)

Battery module 12 Ah
(6EP1935-6MF01)

Battery module 2.5 Ah
(6EP1935-6MD31)

1A

34.5 min

2.6 h

5.4 h

9h

2h

2A

15 min

1h

2.6 h

4.6 h

1h

3A

9 min

39.3 min

1.6 h

2.9 h

37.5 min

4A

6.5 min

27.1 min

1.2 h

2.2 h

27 min

6A

3.5 min

17.5 min

41 min

1.2 h

17.6 min

8A

-

12.1 min

28.6 min

53.3 min

12.5 min

10 A

-

9 min

21.8 min

43.5 min

8.8 min

12 A

-

-

17.3 min

33.3 min

6.8 min

14 A

-

-

15.1 min

27.5 min

5.1 min

16 A

-

-

12.5 min

23.8 min

4.3 min

20 A

-

-

9.1 min

20.1 min

-

25 A

-

-

-

12.6 min

-

30 A

-

-

-

9.1 min

-

Important information for selecting the battery capacity:
• Determination of the mains buffering times is based on the
discharge period of new or non-aged, completely charged
battery modules at a battery temperature not below +25 °C to
the shutdown of the DC UPS.
• Battery aging reduces the still available battery capacity up
until the end of the service life to typically around 50 % of the
original capacity value when new (1.2 Ah/3.2 Ah/7 Ah, etc.)
and the internal resistance increases. When the message
"Battery charge > 85%" appears, only around 50% x 85% =
approx. 43% of the originally available capacity can be
assumed at the end of the battery service life.

5

At battery temperatures below +25 °C, the available capacity
is further reduced by approx. 30% at +5 °C battery temperature to approx. 70% of approx. 43%, leaving only approx.
30% of the original capacity available.
Accordingly, a significantly greater battery capacity must be
selected when configuring the system: A drop to approx. 50%
is compensated for by selecting 1/approx. 0.5 = approx.
double the battery capacity (than required according to the
table for the relevant load current and the relevant buffering
time). Available capacity of approx. 43% is compensated for
by selecting 1/approx. 0.43 = approx. 2.33 times the battery
capacity. Available capacity of approx. 30% is compensated
for by selecting 1/approx. 0.3 = approx. 3.33 times the battery
capacity.

Siemens ST 80 / ST PC · 2013

5/179

© Siemens AG 2013

PC-based Automation
DC UPS with battery modules
DC UPS with battery modules

■ Overview (continued)

■ More information

Recommendation:
• Instead of installing double the battery capacity to cope with
battery aging, regular battery replacement midway through
the expected service life (reduction of capacity to approx.
50%) can be more advisable for the following reasons: Until
the middle (or somewhat past the middle) of the anticipated
battery service life is reached, the capacity does not drop
below 100 %. If the battery is replaced on a regular basis after
reaching half of the anticipated service life, only single
(instead of double) battery capacity must be installed
(→ neutral price in terms of battery module costs, but only
half of the space requirement).
When swapped after half of the service life, the large scatter
range of the residual capacity, which is not defined in more
detail by battery manufacturers, can be avoided at the end of
the service life (after the full time, many batteries are over or
under the average of 50 % remaining capacity; this means
that even if double the capacity is installed, the effect of aging
at the end of the service life is not reliably compensated for,
but only typically). If the battery is swapped after half of the
anticipated service life, the projected buffering time is much
more reliably adhered to.
For batteries stored in a cool place below +25 °C and for no
longer than approx. 4 months, the following service life can
usually be assumed, highly dependent on the battery temperature):

5

Battery
temperature

Drop to
approx. 50%
of residual
capacity

Recommendation: Replace
(at 100% of
residual
capacity)
all

+20 °C

4 years

2 years

+30 °C

2 years

1 year

+40 °C

1 year

0.5 years

Alternative
recommendation

Install double
capacity and
replace
1 x per year

In normal cases (installation in the coolest location in the control
cabinet at approx. +30 °C), the battery should be replaced with
single installed battery capacity in accordance with the selection
table after 1 year of operation!
• On the DC UPS module 40 A, at least 2 battery modules of
7 Ah or higher must be connected in parallel for output
currents > 30 A. When connecting battery modules in parallel,
you must ensure identical capacity and aging.
• After a power failure, and at the end of the selected buffering
time, the battery module is disconnected electronically from
the loads as soon as the 24 V input voltage returns either
automatically or by opening the On/Off control circuit, and
quickly recharged with the charge current of the relevant
DC UPS module (with I-U charge characteristic: initially
constant current I for fast charging, and changeover to
constant voltage U to maintain the charge when the battery
is almost full).

5/180

Siemens ST 80 / ST PC · 2013

You can select the appropriate power supply quickly and easily
using the SITOP Selection Tool:
http://www.siemens.com/sitop-selection-tool

© Siemens AG 2013

PC-based Automation
DC UPS with battery modules
DC UPS module 6 A
DC UPS module 15 A

■ SITOP DC UPS module 6 A

■ SITOP DC UPS module 15 A

• Compact design, only 50 mm wide
• Simple DIN rail mounting
• Completely uninterruptible mains buffering through immediate
electronic connection of the battery as soon as the DC UPS
input voltage falls below the value set by means of
DIP switches.
• High level of safety and availability through monitoring of
operational readiness, battery supply line, battery aging
(message "Battery replacement necessary") and battery
charge (message "Battery charged >85 %")
• Support for automatic warm restart of industrial PCs through
selectable shutdown characteristics.
• Optionally with serial or USB interface.
SW tool available for download from
http://www.siemens.com/sitop
Executes under Windows NT4.0, Windows 2000 and
Windows XP.

■ Ordering data
SITOP DC UPS module 6 A
• With serial interface
• With USB interface

Order No.
6EP1931-2DC21
6EP1931-2DC31
6EP1931-2DC42

• Compact design, only 50 mm wide
• Completely uninterruptible mains buffering through immediate
electronic connection of the battery as soon as the DC UPS
input voltage falls below the value set by means of
DIP switches.
• High level of safety and availability through monitoring of
operational readiness, battery supply line, battery aging
(message "Battery replacement necessary") and battery
charge (message "Battery charged >85%")
• Support for automatic warm restart of industrial PCs through
selectable shutdown characteristics.
• Optionally with serial or USB interface.
SW tool available for download from
http://www.siemens.com/sitop
Executes under Windows NT4.0, Windows 2000 and
Windows XP.

■ Ordering data

Order No.

SITOP DC UPS module 15 A
• With serial interface
• With USB interface

6EP1931-2EC21
6EP1931-2EC31
6EP1931-2EC42

SIPLUS PS DC UPS module 15 A

6AG1931-2EC21-2AA0

(Extended temperature range
-25 ... +60 °C)

Siemens ST 80 / ST PC · 2013

5/181

5

© Siemens AG 2013

PC-based Automation
DC UPS with battery modules
DC UPS module 40 A
Battery module 1.2 Ah

■ SITOP DC UPS module 40 A

5

■ Battery module 1.2 Ah

• Compact design, only 102 mm wide
• Completely uninterruptible mains buffering through immediate
electronic connection of the battery as soon as the DC UPS
input voltage falls below the value set by means of
DIP switches.
• High level of safety and availability through monitoring of
operational readiness, battery supply line, battery aging
(message "Battery replacement necessary") and battery
charge (message "Battery charged >85 %")
• Support for automatic warm restart of industrial PCs through
selectable shutdown characteristics.
• Optionally with USB interface.
SW tool available for download from
http://www.siemens.com/sitop
Executes under Windows NT4.0, Windows 2000 and
Windows XP.

■ Ordering data

Order No.

SITOP DC UPS module 40 A
• With USB interface

6EP1931-2FC21
6EP1931-2FC42

SIPLUS PS DC UPS module 40 A

6AG1931-2FC21-7AA0

(extended temperature range
+25 A ... +70 A °C and medial
loading)

5/182

Siemens ST 80 / ST PC · 2013

• Battery module for DC UPS module 6 A
• It has two maintenance-free, closed lead-acid batteries
(from the same lot) which are installed in a holder and
connected in series with corrosion-resistant lead-calcium
high-performance grid plates and glass fiber.
• Completely prewired with battery retainer and terminals
• Low self-discharge rate of approximately 3 % per month
(at +20 °C)

■ Ordering data
Battery module 24 V/1.2 Ah
for DC UPS module 6 A

Order No.
6EP1935-6MC01

© Siemens AG 2013

PC-based Automation
DC UPS with battery modules
Battery module 2.5 Ah
Battery module 3.2 Ah

■ Battery module 24 V/2.5 Ah

■ Battery module 24 V/3.2 Ah

• High-temperature battery module for DC UPS module
6 A and 15 A
• It has two maintenance-free, closed pure lead-acid batteries
(from the same lot), which are installed in a holder and
connected in series.
• Completely prewired with battery retainer and terminals
• Low self-discharge rate of approximately 3 % per month
(at +20 °C)

■ Ordering data
Battery module 24 V/2.5 Ah
for DC UPS module 15 A

Order No.
6EP1935-6MD31

• Battery module for DC UPS module 6 A and 15 A
• It has two maintenance-free, closed lead-acid batteries
(from the same lot) which are installed in a holder and
connected in series with corrosion-resistant lead-calcium
high-performance grid plates and glass fiber.
• Complete with battery retainer and terminals
• Low self-discharge rate of approximately 3 % per month
(at +20 °C)

■ Ordering data
Battery module 24 V/3.2 Ah

Order No.
6EP1935-6MD11

for DC UPS module 15 A

5

Siemens ST 80 / ST PC · 2013

5/183

© Siemens AG 2013

PC-based Automation
DC UPS with battery modules
Battery module 7 Ah
Battery module 12 Ah

■ Battery module 7 Ah

■ Battery module 12 Ah

• Battery module for DC UPS module 6 A, 15 A and DC UPS
module 40 A (for > 30 to 40 A, 2 units are required in parallel)
• It has two maintenance-free, closed lead-acid batteries
(from the same lot) which are installed in a holder and
connected in series with corrosion-resistant lead-calcium
high-performance grid plates and glass fiber.
• Completely pre-wired with terminals and battery retainer
• Low self-discharge rate of approximately 3% per month
(at +20 °C)

■ Ordering data
Battery module 24 V/7 Ah

5

Order No.
6EP1935-6ME21

for DC UPS module 6 A,
15 A and 40 A

5/184

Siemens ST 80 / ST PC · 2013

• Battery module for DC UPS module 6 A, 15 A and DC UPS
module 40 A (for > 30 to 40 A, 2 units are required in parallel)
• It has two maintenance-free, closed lead-acid batteries
(from the same lot) which are installed in a holder and
connected in series with corrosion-resistant lead-calcium
high-performance grid plates and glass fiber.
• Completely pre-wired with terminals and battery retainer
• Low self-discharge rate of approximately 3% per month
(at +20 °C)

■ Ordering data
Battery module 24 V/12 Ah
for DC UPS module 6 A,
15 A and 40 A

Order No.
6EP1935-6MF01

© Siemens AG 2013

PC-based Automation
MASTERGUARD power supply
MASTERGUARD power supply

■ Overview

■ More information

MASTERGUARD UPS
• The A-19 and EI-19 series of Masterguard offer effective online
protection against all kinds of power supply disturbances
• Genuine online operating principle, i.e. complete disconnection of the load from the irregularities of the line power
supply
• 19" compact modules
• Simple operation and functional indication of operating states
and load stages

http://www.masterguard.de

MASTERGUARD UPS Series A-19/EI-19
• Permanent double-converter technology evens out any
irregularity in the power supply and offers totally uninterrupted
protection
• Easily configurable for use in 19" cabinets thanks to battery
expansions and universal slide rail units
• With a height of just 2 HU for the A-19 series and 3 HU for the
EI-19 series and with power-regulated fan and functional
display, these units are ideal where space is limited.
• For communication, a choice can be made between serial and
USB interface and, in addition, a network connection of the
UPS can be set up by means of an SNMP plug-in card for the
communication slot.

Information hotline: +49 180-532 37 51

Sales contact:
MASTERGUARD GmbH
Mr. Willi Brinkmann
Phone: +49 9131 6300 248
Fax: +49 9131 6300 271
E-mail: willi.brinkmann@masterguard.de

Service contact:
MASTERGUARD GmbH
Mr. Alexander Zink
Phone: +49 9131 6300 218
Fax: +49 9131 6300 281
E-mail: alexander.zink@masterguard.de
Support line: +49 180-522 10 96

Standard configuration
MASTERGUARD UPS Series A-19
• A700-19
Output: 700 VA; integrated battery: 6 min.
• A1000-19
Output: 1000 VA; integrated battery: 7 min.
• A2000-19
Output: 2000 VA
• A3000-19
Output: 3000 A

5

Battery pack for MASTERGUARD Series A-19
• BPA 1000-19
for UPS A1000-19 (max. 2 BP)
• BPA 3000-19
for UPS A2000-19 (max. 5 BP) and UPS A3000-19 (max. 5 BP)
Accessories
Slide rail unit 2 HU 330-580 mm
Slide rail unit 2 HU 575-855 mm
Standard configuration
MASTERGUARD UPS Series El-19
• EI-19
Output: 6000 VA
Battery pack for MASTERGUARD Series EI-19
• BPEI-19
Accessories
Slide rail unit 3 HU 330-580 mm
Slide rail unit 3 HU 575-855 mm
ManageUPS SNMP adapter card
MopUPS shutdown software
• for Intel operating systems (Windows, Linux, Solaris for Intel)
• for Risc operating systems (Solaris SPARC, HPUX, AIX)

Siemens ST 80 / ST PC · 2013

5/185

© Siemens AG 2013

PC-based Automation
Communication — Industrial Ethernet
Connection options to SIMATIC IPCs

■ Overview
The operating systems listed in the table refer exclusively to the
communication products specified! Please refer to the

description of the relevant IPC for the operating system that is
available and has been released for that IPC.
Embedded Systems

-

-

SIMATIC S7 modular
Embedded Controller

-

SIMATIC IPC627C

○

SIMATIC HMI IPC677C

○

SIMATIC
Industrial-PC
SIMATIC IPC427C,
SIMATIC HMI IPC477C

○

Windows XP Embedded +
SP1/SP2/FP 2007

SIMATIC IPC427C

•
•
•
•
•
•
•
•
•

-

SIMATIC IPC627C

SIMATIC IPC827C

SIMATIC IPC547C/D

Op.
sys.

• • •
• ○ •
• • •
• ○ •
○
○
•
• • •
• ○ •
○
○
•
• • •
• • •
• • •
• • •
• • •
• • •
• • •
• • •
• • •

SIMATIC IPC847C

Field PG M3

SIMATIC Industrial PC/
Field PG
other operating systems

Windows Server 2003
R2 / SP2

Windows XP Pro + SP3

Vista Business /
Ultimate + SP1/2

Windows Server 2008 +
SP1/2

Windows Server 2008 R2

Operating system environment of the
communication software
Windows 7 Professional /
Ultimate

Communication Communication
hardware
software

CPs and software for Industrial Ethernet
HARDNET-IE S7
(S7-1613)
HARDNET-IE S7
REDCONNECT 3)
S7 OPC Redundancy for
Industrial Ethernet
HARDNET-IE S7
(S7-1613)
HARDNET-IE S7
REDCONNECT 3)
S7 OPC Redundancy for
Industrial Ethernet
HARDNET-IE S7
(S7-1613)
HARDNET-IE S7
REDCONNECT 3)
S7 OPC Redundancy for
Industrial Ethernet

CP 1613 A2
(PCI 32 Bit)

CP 1623
(PCIe x1)

CP 1628
(PCIe x1)

SOFTNET-IE S7
SOFTNET-IE S7 Lean
SOFTNET-IE PG
S7 OPC Redundancy for
Industrial Ethernet

SIMATIC PG/PC
with integral
Ethernet
interface

SOFTNET-IE S7
SOFTNET-IE S7 Lean
SOFTNET-IE PG
S7 OPC Redundancy for
Industrial Ethernet

• • •
• • •
-

-

-

• • •
• • •
-

-

-

• • •
• • •
• • •
-

-

-

• • •
• • •
• • •
-

-

-

-

-

•
•
•
•

•
•
•
•
○5)

•
•
○5)

•
•
•
•

•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•

○

-

-

○

4)5)

5)

5)

4)5)

5)

5)

4)5)

-

• •
○4)5) ○4)5)

• •
○5)

○5)

○4)5) ○4)5)
○5)

•

○

○5)

5)

○4)5) ○4)5)

•
•
•
•

•
•
•
•
•
•
•
•

•
•
•
•
•
•
•
•
•

○

-

○

○

○

○

-

-

○5)

-

•
•
•
•

CPs and software for PROFINET
CP 1616 1)
(PCI 32 Bit)

HARDNET PN IO DK
(DK-16xx PN IO) 1)

CP 1604 1)
(PCI-104)

HARDNET PN IO DK
(DK-16xx PN IO) 1)

SIMATIC PG/PC
with integral
Ethernet
interface

SOFTNET PN IO

• - - - • • - - - • • • • • • •

1) Use of these CPs requires porting of the Development Kit DK-16xx PN IO to the relevant operating system environment. You can order the DK-16xx PN IO at www.siemens.com/simatic-net/
dk16xx on the Internet. It contains sample software for Linux Suse 12 and Windows XP Professional. For IRT operation an exclusive interrupt is necessary; this is not available in all slots.
The additional use of CP 1616/CP 1604 is not approved for SIMATIC Industrial PC versions and
integrated PROFINET interface.
2) possible with restrictions, if necessary, depending on memory expansion and processor capacity
3) requires at least 2 PCI or 2 PCIe slots (4-way redundancy requires 4 free PCI or 4 PCIe slots!);
hybrid configurations with CP 1613 A2 (PCI) and CP 1623 (PCIe) are possible,
depending on PC expansion
4) without 4-way redundancy as there are only 2 slots
5) depending on the slots of the selected PC version

Connection options of Industrial Ethernet CPs to PG/PC/IPC

5/186

Siemens ST 80 / ST PC · 2013

○

-

-

• • • • • • • • • • •

○

2)

Notes
- Please always note the supplementary conditions for the specified
SIMATIC NET products that you can view on the Internet pages
shown below.
- for further details on XP embedded, see
http://support.automation.siemens.com/WW/view/en/21661049
- further details on system requirements and operating environments
can be found in the Readme file of the communication products on
the SIMATIC NET PC Software V8.1 CD
- Updates and supplements to the catalog entries, as well as the above tables can be viewed at
http://www.siemens.com/simatic-net/ik-info

2)

•

-

suitable

-

not suitable

○

suitable under
certain conditions

*B,.B;;B

5

CP 1612 A2
(PCI 32 Bit)

• • •
• • •
- • • • •
• • •
- • • • • • - • • • •
• • •
• • •
- • • • •
• • •
• • •
- • -

© Siemens AG 2013

PC-based Automation
Communication — Industrial Ethernet
CP 1604

■ Overview
• PCI-104 module for connecting PCI-104 systems to
PROFINET IO
• Full/half duplex with autonegotiation
• With Ethernet real-time ASIC ERTEC 400
• Integral 4-port real-time switch
• Communication services:
- PROFINET IO controller and/or PROFINET IO device
- Support of IRT in motion control applications
- Support of PROFIenergy functionality
• High performance through direct memory access
• Integration in network management systems through the
support of SNMP
• Comprehensive diagnostics possibilities for installation,
start-up and operation of the module
• Powerful configuration tools are included in delivery of module
7&3
8'3

31

053

23&

3*23 66

,7
*B,.B;;B

,62

■ Ordering data
CP 1604
communications processor

Order No.
6GK1160-4AA01

Connection board for CP 1604

PCI-104 card (32-bit) with
ASIC ERTEC 400 for connecting
PCI-104 systems to PROFINET IO
with 4-port real-time switch (RJ45);
incl. IO-Base software for
PROFINET IO-Controller and
NCM PC; single license for one
installation, runtime software,
software and electronic manual on
CD-ROM, Class A, for 32-bit
Windows XP Professional and
Windows 7;
other operating systems using
DK-16xx PN IO Development Kit
German/English
CP 1604 Microbox Package

Order No.
Accessories
6GK1160-4AC00

Connection board for CP 1604 with
four RJ45 sockets incl. connecting
cable
Power supply for CP 1604

6GK1160-4AP00

Redundant power supply for
CP 1604 for operating the integral
4-port switch of the CP 1604 with
the PC-104 system switched off;
includes connecting cable
Development Kit DK-16xx PN IO

6GK1160-4AU01

Package for implementing
the CP 1604 in the
SIMATIC Microbox PC; comprising
the CP 1604, connection board,
power supply and expansion racks
for Microbox PC; for use with Development Kit DK-16xx PN IO; NCM PC

Software Development Kit for
CP 1616/CP 1604;
driver and IO-Base software for
CP 1616/CP 1604 as PN IO controller and PN IO device in source code
for transfer to other PC-based operating systems; incl. executable
sample code for SUSE Linux 10,
Windows XP Professional and
Windows 7

5
See http://www.siemens.com/
simatic-net/dk16xx

IE TP Cord RJ45/RJ45
TP cable 4 x 2
with 2 RJ45 connectors
• 0.5 m
•1m
•2m
•6m
• 10 m

6XV1870-3QE50
6XV1870-3QH10
6XV1870-3QH20
6XV1870-3QH60
6XV1870-3QN10

SCALANCE X204IRT

6GK5204-0BA00-2BA3

Managed Industrial Ethernet
switches; isochronous real time,
LED diagnostics, error signaling
contact with SET button,
redundant power supply
4 x 10/100 Mbit/s RJ45 ports

■ More information
The DK-16xx PN IO development kit can be found
on the Internet at:
http://www.siemens.com/simatic-net/dk16xx

Siemens ST 80 / ST PC · 2013

5/187

© Siemens AG 2013

PC-based Automation
Communication — Industrial Ethernet
CP 1616

■ Overview

7&3
8'3

31

053

23&

3*23 66

,7
*B,.B;;B

,62

• PCI module for connecting PCs and SIMATIC PGs/PCs
to PROFINET IO (Universal Keyed 3.3 V and 5 V;
33 MHz/66 MHz; 32-bit, runs in 64-bit PCI-X systems)
• Full/half duplex with autonegotiation
• With Ethernet real-time ASIC ERTEC 400
• Integral 4-port real-time switch
• Communication services:
- PROFINET IO controller and/or PROFINET IO device
- Support of IRT in motion control applications
• High performance through direct memory access
• Integration in network management systems through the
support of SNMP
• Comprehensive diagnostics possibilities for installation,
start-up and operation of the module
• Powerful configuration tools are part of the scope of delivery
of the module

■ Ordering data
CP 1616
communications processor

5

Order No.
6GK1161-6AA02

PCI Card (32 bit; 3.3/5 V universal
keyed) with ASIC ERTEC 400 for
connecting PCs to PROFINET IO
with 4-Port-Real-Time-Switch
(RJ45); incl. IO Base Software for
PROFINET IO Controller and
NCM PC; single license for one
installation, runtime software,
software and electronic manual
on CD-ROM, Class A, for 32-bit
Windows XP Professional and
Windows 7; other operating systems
via Development Kit DK-16xx PN IO;
German/English

Order No.
Accessories
Development Kit DK-16xx PN IO
Software development kit for
CP 1616/CP 1604;
driver and IO-Base software for
CP 1616/CP 1604 as PN IO controller and IO device in source code for
transfer to other PC-based operating systems; including executable
example code for SUSE Linux 10,
Windows XP Professional and
Windows 7
IE TP Cord RJ45/RJ45
TP cable 4 x 2
with 2 RJ45 connectors
• 0.5 m
•1m
•2m
•6m
• 10 m

6XV1870-3QE50
6XV1870-3QH10
6XV1870-3QH20
6XV1870-3QH60
6XV1870-3QN10

SCALANCE X204IRT

6GK5204-0BA00-2BA3

Managed Industrial Ethernet
switches; isochronous real time,
LED diagnostics, error signaling
contact with SET button,
redundant power supply
4 x 10/100 Mbit/s RJ45 ports

■ More information
The DK-16xx PN IO development kit can be found
on the Internet at:
http://www.siemens.com/simatic-net/dk16xx

5/188

Siemens ST 80 / ST PC · 2013

See http://www.siemens.com/
simatic-net/dk16xx

© Siemens AG 2013

PC-based Automation
Communication — Industrial Ethernet
CP 1612 A2

■ Overview
• PCI card (32 bit; 33 MHz/66 MHz; 3.3 V/5 V Universal Key)
for the connection of PG/PC to Industrial Ethernet
• 1 x 10/100/1000 Mbit/s RJ45 port, electrical
• Automatic data transmission rate detection
(10/100/1000 Mbit/s), with autosensing and autocrossover
function
• Communication services via
- PROFINET
- ISO or TCP/IP transport protocol
- PG/OP communication
- S7 communication
- Open communication (SEND/RECEIVE)
• Designed for use in industrial environments
• The appropriate OPC servers and configuration tools are
included in the scope of supply of the respective communication software.
7&3
8'3

31

053

23&

3*23 66

,7
*B,.B;;B

,62

■ Ordering data
CP 1612 A2
communications processor

Order No.
6GK1161-2AA01

Software for designing secure
IP-based VPN connections from a
programming device/PC to network
segments which are secured by
SCALANCE S in bridge mode;
Single license for 1 installation,
runtime software (German/English),
configuring tool (German/English)
and electronic manual on CD-ROM
(German/English/French/Italian/
Spanish) for 32-bit Windows,
XP Professional + SP1, SP2, SP3;
for 32/64-bit Windows 7 Ultimate/
Business

SOFTNET PN IO
Software for PROFINET IO Controller
with OPC server and NCM PC,
runtime software, software and electronic manual on CD-ROM, license
key on USB flash drive, Class A

PCI card (32 bit, 33 MHz/66 MHz;
3.3 V/5 V universal keyed) for connection to Industrial Ethernet
(10/100/1000 Mbit/s) with RJ45
interface, incl. driver for 32-bit
Windows XP Professional SP2/3,
2003 R2 Server SP2, Vista Business/
Ultimate SP1, Windows 2008 Server;
German/English
SOFTNET Security Client V4

Order No.

SOFTNET-IE PN IO V8.2

6GK1704-1VW04-0AA0

For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single License for one installation

5
6GK1704-1HW08-2AA0

SOFTNET PN IO Edition 2008
(V7.1)
For 32-bit
Windows XP Professional SP 2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/
Ultimate SP1; Windows 2008 Server;
English/German
• Single License for one installation

6GK1704-1HW71-3AA0

Software Update Service

6GK1704-1HW00-3AL0

For 1 year with automatic extension;
requirement: current software
version
Upgrade
• From Edition 2006 to
SOFTNET PN IO Edition 2008
or V8.1
• From V6.0, V6.1, V6.2 or V6.3 to
SOFTNET PN IO Edition 2008 or
V8.1

6GK1704-1HW00-3AE0

6GK1704-1HW00-3AE1

Siemens ST 80 / ST PC · 2013

5/189

© Siemens AG 2013

PC-based Automation
Communication — Industrial Ethernet
CP 1612 A2

■ Ordering data

Order No.
SOFTNET-IE PG
for Industrial Ethernet

Software for S7 and open communication, incl. OPC server, PG/OP
communication, and NCM PC,
runtime software, software and
electronic manual on CD-ROM,
license key on a USB stick, Class A

Software for PG/OP communication,
runtime software, software and electronic manual on CD-ROM, license
key on USB flash drive, Class A

SOFTNET-IE S7 V8.2

For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2;
German/English
• Single License for one installation

SOFTNET-IE PG V8.2

For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2;
German/English
Up to 64 connections
• Single License for one installation

6GK1704-1CW08-2AA0

For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/
Ultimate SP1; Windows 2008 Server;
English/German
Up to 64 connections
• Single License for one installation

6GK1704-1CW71-3AA0

Software Update Service

6GK1704-1CW00-3AL0

For 1 year with automatic extension;
requirement: current software version
Upgrade
• From Edition 2006 to
Edition 2008 or V8.1
• From V6.0, V6.1, V6.2 or V6.3 to
Edition 2008 or V8.1

6GK1704-1PW08-2AA0

SOFTNET-PG Edition 2008 (V7.1)
for Industrial Ethernet

SOFTNET S7 Edition 2008 (V7.1)
for Industrial Ethernet

5

Order No.

SOFTNET S7
for Industrial Ethernet

6GK1704-1CW00-3AE0

For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/
Ultimate SP1; Windows 2008 Server;
English/German
• Single License for one installation

6GK1704-1PW71-3AA0

Software update

6GK1704-1PW00-3AL0

For 1 year with automatic extension;
requirement: current software version
Upgrade
• From Edition 2006 to
Edition 2008 or V8.1
• From V6.0, V6.1, V6.2 or V6.3 to
Edition 2008 or V8.1

6GK1704-1PW00-3AE0
6GK1704-1PW00-3AE1

IE TP Cord RJ45/RJ45
TP cable 4 x 2
with 2 RJ45 connectors
• 0.5 m
•1m
•2m
•6m
• 10 m

6XV1870-3QE50
6XV1870-3QH10
6XV1870-3QH20
6XV1870-3QH60
6XV1870-3QN10

SOFTNET-S7 Lean Edition 2008
(V7.1) for Industrial Ethernet

Software Update Service

6GK1706-0HB00-3AL0

Up to eight connections
• Single License for one installation

6GK1704-1LW71-3AA0

For 1 year with automatic extension;
requirement: current software version

Software Update Service

6GK1704-1LW00-3AL0

6GK1704-1CW00-3AE1

SOFTNET-IE S7 Lean Edition V8.2
Up to eight connections
• Single License for one installation

6GK1704-1LW08-2AA0

For 1 year with automatic extension;
requirement: current software
version
Upgrade
• From Edition 2006 to
Edition 2008 or V8.1
• From V6.0, V6.1, V6.2 or V6.3 to
Edition 2008 or V8.1

5/190

6GK1704-1LW00-3AE0
6GK1704-1LW00-3AE1

Siemens ST 80 / ST PC · 2013

Upgrade
• From Edition 2006 and higher to
Edition 2008, single license
• From V6.0 to Edition 2008,
single license

6GK1706-0HB00-3AE0
6GK1706-0HB00-3AE1

© Siemens AG 2013

PC-based Automation
Communication — Industrial Ethernet
CP 1613 A2

■ Overview

■ Ordering data

Order No.

CP 1613 A2
communications processor

6GK1161-3AA01

PCI card (32-bit, 33 MHz/66 MHz;
3.3 V/5 V universal keyed) for
connection to Industrial Ethernet
(10/100 Mbit/s) with ITP and RJ45
connection over HARDNET-IE S7/
S7-1613 and S7-REDCONNECT,
for operating system support see
SIMATIC NET Software
HARDNET-IE S7
for Industrial Ethernet
Software for S7 and open communication, incl. PG/OP communication,
OPC server and NCM PC; up to
120 connections, runtime software,
software and electronic manual on
CD-ROM, license key on USB stick,
Class A; for CP 1613/CP 1613 A2/
CP 1623/CP 1628;
HARDNET-IE S7 V8.2

7&3
8'3

31

053

23&

3*23 66

,7
*B,.B;;B

,62

• PCI card (32 bit; 33 MHz/66 MHz; 3.3 V/5 V universal key) with
microprocessor for connection of PG/PC to Industrial Ethernet
with 10/100 Mbit/s Autosensing/Autonegotiation
• Communication services using
- Open IE communication via TCP/IP and UDP)
- ISO transport protocol
- PG/OP communication
- S7 communication
- Open communication (SEND/RECEIVE)
• 15-pole ITP connection
• RJ45 connection
• Time synchronization
• ISO and TCP/IP transport protocol onboard
• SNMP-supported diagnostics
• The appropriate OPC server and configuration tools are
included in the respective scope of supply of the communication software

For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single License for one installation

6GK1716-1CB08-2AA0

S7-1613 Edition 2008 (V7.1)
For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/
Ultimate SP1; Windows 2008 Server;
English/German
• Single License for one installation

6GK1716-1CB71-3AA0

Software Update Service

6GK1716-1CB00-3AL0

For 1 year with automatic extension;
requirement: current software
version
Upgrade
• S7-1613, Edition 2006 or higher,
to S7-1613 Edition 2008 or
HARDNET-IE S7 V8.1
• from S7-1613 V6.0, V6.1, V6.2 or
V6.3 to S7-1613 Edition 2008 or
HARDNET-IE S7 V8.1

5
6GK1716-1CB00-3AE0

6GK1716-1CB00-3AE1

IE TP Cord RJ45/RJ45
TP cable 4 x 2
with 2 RJ45 connectors
• 0.5 m
•1m
•2m
•6m
• 10 m
1)

6XV1870-3QE50
6XV1870-3QH10
6XV1870-3QH20
6XV1870-3QH60
6XV1870-3QN10

also S5-compatible communication

Siemens ST 80 / ST PC · 2013

5/191

© Siemens AG 2013

PC-based Automation
Communication — Industrial Ethernet
CP 1623

■ Overview

■ Ordering data
CP 1623
communications processor

Order No.
6GK1162-3AA00

PCI Express x1 card for connection
to Industrial Ethernet
(10/100/1000 Mbit/s), with 2-port
switch (RJ45) via HARDNET-IE S7/
S7-1613 and S7-REDCONNECT.
For operating system support,
see SIMATIC NET Software
HARDNET-IE S7
for Industrial Ethernet
Software for S7 and open communication, incl. PG/OP communication,
OPC server and NCM PC; up to
120 connections, runtime software,
software and electronic manual on
CD-ROM, license key on USB stick,
Class A; for CP 1613/CP 1613 A2/
CP 1623/CP 1628;
HARDNET-IE S7 V8.2

7&3
8'3

31

053

23&

3*23 66

,7
*B,.B;;B

,62

5

• PCI Express Card (PCIe x1) with an internal microprocessor
for connection of PG/PC to Industrial Ethernet
• 10/100/1000 Mbit/s
(Autosensing/Autocrossover/Autonegotiation)
• Integrated 2-port switch (2 x RJ45 connection)
• Communications services via
- Open IE communication (TCP/IP and UDP)
- ISO transport protocol
- PG/OP communication
- S7 communication
- Open communication (SEND/RECEIVE)
• Time synchronization
• ISO and TCP/IP transport protocol on board
• Integration into network management systems through the
support of SNMP (V1)
• The appropriate OPC server and configuration tools are
included in the scope of supply of the respective communication software.

5/192

Siemens ST 80 / ST PC · 2013

For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single License for one installation

6GK1716-1CB08-2AA0

S7-1613 Edition 2008 (V7.1)
For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/
Ultimate SP1; Windows 2008 Server;
English/German
• Single License for one installation

6GK1716-1CB71-3AA0

Software Update Service

6GK1716-1CB00-3AL0

For 1 year with automatic extension;
requirement: current software version
Upgrade
• S7-1613, Edition 2006 or higher,
to S7-1613 Edition 2008 or
HARDNET-IE S7 V8.1
• from S7-1613 V6.0, V6.1, V6.2 or
V6.3 to S7-1613 Edition 2008 or
HARDNET-IE S7 V8.1

6GK1716-1CB00-3AE0

6GK1716-1CB00-3AE1

IE TP Cord RJ45/RJ45
TP cable 4 x 2
with 2 RJ45 connectors
• 0.5 m
•1m
•2m
•6m
• 10 m

6XV1870-3QE50
6XV1870-3QH10
6XV1870-3QH20
6XV1870-3QH60
6XV1870-3QN10

© Siemens AG 2013

PC-based Automation
Communication — Industrial Ethernet
CP 1628

■ Overview

■ Ordering data

Order No.

Communications processor
CP 1628 1)

6GK1162-8AA00

PCI Express x1 card for connection
to Industrial Etherne
t (10/100/1000 Mbps),
with 2-port switch (RJ45) and
integrated security (firewall, VPN)
via HARDNET-IE S7 and
S7-REDCONNECT.
For operating system support,
see SIMATIC NET Software
HARDNET S7
for Industrial Ethernet
Software for S7 and open communication, incl. PG/OP communication,
OPC server and NCM PC; up to
120 connections, runtime software,
software and electronic manual on
CD-ROM, license key on USB stick,
Class A; for CP 1613/CP 1613 A2/
CP 1623/CP 1628;

7&3
8'3

31

053

23&

3*23 66

HARDNET-IE S7 V8.2

,7
*B,.B;;B

,62

• PCI Express card (PCIe x1) with its own microprocessor
and integrated 2-port switch (2 x RJ45 connection,
10/100/1000 Mbit/s) for the connection of a PG/PC to
Industrial Ethernet
• Integrated security mechanisms (e.g. Firewall, VPN)
• ISO and TCP/IP transport protocol on board
• Communications services via
- Open IE communication (TCP/IP and UDP)
- ISO transport protocol
- PG/OP communication
- S7 communication
- Open communication (SEND/RECEIVE)
• Integration into network management systems through the
support of SNMP (V1/V3)

For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single license for one installation

6GK1716-1CB08-2AA0

Software Update Service

6GK1716-1CB00-3AL0

For one year with automatic
extension;
requirement:
Current software version
Upgrade
• S7-1613, Edition 2006 or higher,
to S7-1613 Edition 2008 or
HARDNET-IE S7 V8.1
• from S7-1613 V6.0, V6.1, V6.2 or
V6.3 to S7-1613 Edition 2008 or
HARDNET-IE S7 V8.1

6GK1716-1CB00-3AE0

5

6GK1716-1CB00-3AE1

IE TP Cord RJ45/RJ45
TP cable 4 x 2
with 2 RJ45 connectors
• 0.5 m
•1m
•2m
•6m
• 10 m
1)

6XV1870-3QE50
6XV1870-3QH10
6XV1870-3QH20
6XV1870-3QH60
6XV1870-3QN10

Shipment without individual export license is restricted to certain countries.
Export to other countries requires an individual export license that must be
applied for from BIS (Bureau of Industry and Security).
Note: Check the current country list:
http://support.automation.siemens.com/WW/view/en/66627157

■ More information
You will find more information on the topic of Industrial Security
on the Internet at:
http://www.siemens.com/industrialsecurity

Siemens ST 80 / ST PC · 2013

5/193

© Siemens AG 2013

PC-based Automation
Communication — Industrial Ethernet
HARDNET-IE S7-REDCONNECT

■ Overview
• For connecting PCs over redundant Industrial Ethernet to the
SIMATIC S7-400H
• Protected from communication failures arising from a fault in
the double bus or in redundant rings
• For redundant Layer 2 or Layer 3 Industrial Ethernet
• Can also be implemented in non-redundant networks
• No additional programming overhead for the PC and
in H systems
• The appropriate OPC server and configuration tools are
included in the scope of supply of the respective communication software
• Enhanced redundancy over 4-way communication
(STEP 7 V5.1 + SP4 and higher)

PC with
2 x CP 1613 A2/CP 1623/CP 1628
and HARDNET-IE
S7-REDCONNECT
Industrial Ethernet

H CPU
in single mode

ET 200M

PROFIBUS

G_IK10_XX_10048

S7-400H

System configuration for S7-REDCONNECT

7&3
8'3

31

053

23&

3*23 66

,7
*B,.B;;B

,62

5

5/194

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
Communication — Industrial Ethernet
HARDNET-IE S7-REDCONNECT

■ Ordering data

Order No.

HARDNET-IE S7-REDCONNECT
Software for fail-safe S7 communication via redundant networks, incl.
S7 OPC server, HARDNET-IE S7,
runtime software, software and electronic manual on CD-ROM, license
key on USB stick, Class A;

For expansion from HARDNET-IE S7
to S7-REDCONNECT, single license
for one installation, runtime software,
software and electronic manual on
CD-ROM, license key on USB stick,
Class A;

HARDNET-IE S7-REDCONNECT
V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single License for one installation

Order No.
HARDNET-IE
S7-REDCONNECT Power Pack

HARDNET-IE S7-REDCONNECT
Power Pack V8.2

6GK1716-0HB08-2AA0

For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2;
German/English;

S7-REDCONNECT Edition 2008
(V7.1)

S7-REDCONNECT Power Pack
Edition 2008 (V7.1)

For 32-bit
Windows XP Professional SP 2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/Ultimate
SP1; Windows 2008 Server;
English/German
• Single License for one installation

For 32-bit
Windows XP Professional SP 2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/
Ultimate SP1; Windows 2008 Server;
English/German
6GK1716-0HB71-3AA0

Software Update Service

6GK1716-0HB00-3AL0

For 1 year with automatic extension;
requirement: current software
version
Upgrade
• From Edition 2006 to
S7-REDCONNECT Edition 2008
or V8.1
• From V6.0, V6.1, V6.2 or V6.3 to
S7-REDCONNECT Edition 2008 or
V8.1

6GK1716-0HB00-3AE0

6GK1716-0HB00-3AE1

6GK1716-0HB08-2AC0

CP 1613 A2
communications processor

6GK1716-0HB71-3AC0

6GK1161-3AA01

PCI card (32-bit, 33 MHz/66 MHz;
3.3 V/5 V universal keyed) for
connection to Industrial Ethernet
(10/100 Mbit/s) with ITP and RJ45
connection over HARDNET-IE S7
and S7-REDCONNECT,
for operating system support see
SIMATIC NET Software
CP 1623
communications processor

6GK1162-3AA00

PCI Express x1 card for
connection to Industrial Ethernet
(10/100/1000 Mbit/s), with 2-port
switch (RJ45) via HARDNET-IE S7
and S7-REDCONNECT.
For operating system support,
see SIMATIC NET Software
CP 1628
communications processor

5
6GK1162-8AA00

PCI Express x1 card for
connection to Industrial Ethernet
(10/100/1000 Mbit/s), with 2-port
switch (RJ45) and integral security
(firewall, VPN) via HARDNET-IE S7
and S7-REDCONNECT.
For operating system support,
see SIMATIC NET software

Siemens ST 80 / ST PC · 2013

5/195

© Siemens AG 2013

PC-based Automation
Communication — Industrial Ethernet
SOFTNET for Industrial Ethernet

■ Overview
zvm{ul{V
ohykul{TplGz^Gˆ•‹G
plGz^GvwjGyŒ‹œ•‹ˆ•Š

zvm{ul{V
ohykul{TplGz^Gˆ•‹G
plGz^GvwjGyŒ‹œ•‹ˆ•Š

• Software for coupling programming devices/workstations to
automation systems
• Communication services:
- PG/OP communication
- S7 communication
- Open communication (SEND/RECEIVE)
• Can be used with
- Layer 2 Ethernet card (PCI/PCIe)
- Integrated Industrial Ethernet interface, e.g. CP 1612 A2
- Modem (Remote Access Service RAS)
• Complete protocol stack as a software package
• Increased availability thanks to additional option packages
such as OPC Server Redundancy

otp

p•‹œš›™ˆ“
l›Œ™•Œ›

S7-1200 ž›G
CSM 1277

n†prXW††XWW[\

z^TZWWGž›G
jwGZ[ZTX

z^T[WWGž›G
jwG[[ZTX

System configuration SOFTNET for Industrial Ethernet

7&3
8'3

31

053

23&

3*23 66

,7
*B,.B;;B

,62

5

5/196

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
Communication — Industrial Ethernet
SOFTNET for Industrial Ethernet

■ Ordering data

Order No.

Order No.

SOFTNET S7
for Industrial Ethernet

SOFTNET-PG
for Industrial Ethernet

Software for S7 and open communication, incl. OPC server, PG/OP
communication, and NCM PC,
runtime software, software and
electronic manual on CD-ROM,
license key on a USB stick, Class A

Software for PG/OP communication,
runtime software, software and electronic manual on CD-ROM, license
key on USB flash drive, Class A

SOFTNET-IE S7 V8.2

For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2;
German/English
• Single License for one installation

SOFTNET-IE PG V8.2

For 32/64-bit
Windows 7 Professional/Ultimate;
for 64-bit: Windows 2008 Server R2;
German/English
Up to 64 connections
• Single License for one installation

6GK1704-1CW08-2AA0

SOFTNET-S7 Edition 2008 (V7.1)
for Industrial Ethernet
For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/Ultimate
SP1; Windows 2008 Server;
English/German
Up to 64 connections
• Single License for one installation

6GK1704-1CW71-3AA0

Software Update Service

6GK1704-1CW00-3AL0

Upgrade
• From Edition 2006 to
Edition 2008 or V8.2
• From V6.0, V6.1, V6.2 or V6.3 to
Edition 2008 or V8.1

6GK1704-1CW00-3AE0
6GK1704-1CW00-3AE1

SOFTNET-IE S7 REDCONNECT
VM V8.2
Software for fail-safe S7 communication via redundant networks, incl.
S7 OPC server, HARDNET-IE S7,
runtime software, software and
electronic manual on CD-ROM,
license key on USB stick, Class A
for 32/64-bit: Windows 7
Professional/Ultimate;
for 64-bit: Windows 2008 Server R2;
German/English;
• Single License for one installation

For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2; Windows Vista Business/
Ultimate SP1; Windows 2008 Server;
English/German
• Single License for one installation

6GK1704-1PW71-3AA0

Software update

6GK1704-1PW00-3AL0

For 1 year with automatic extension;
requirement: current software
version
6GK1704-1PW00-3AE0
6GK1704-1PW00-3AE1

IE S7 OPC Redundancy
Software for redundant OPC servers
in the environment of Industrial
Ethernet software, S7 products,
runtime software, software and
electronic manual on CD-ROM,
license key on USB flash drive,
Class A

5

IE S7 OPC Redundancy V8.2

6GK1704-0HB08-2AA0

SOFTNET-IE S7 Lean Edition V8.2
Up to eight connections
• Single License for one installation

SOFTNET-PG Edition 2008 (V7.1)
for Industrial Ethernet

Upgrade
• From Edition 2006 to
Edition 2008 or V8.1
• From V6.0, V6.1, V6.2 or V6.3 to
Edition 2008 or V8.1

For 1 year with automatic extension;
requirement: current software version

6GK1704-1PW08-2AA0

For 64-bit:
Windows 2008 Server R2;
German/English
• Single License for one installation
• Software Update Service
for one year,
with automatic extension;
requirement:
current software version

6GK1706-1CW08-2AA0
6GK1706-1CW00-3AL0

6GK1704-1LW08-2AA0

SOFTNET-S7 Lean Edition 2008
(V7.1) for Industrial Ethernet
Up to eight connections
• Single License for one installation

6GK1704-1LW71-3AA0

Software Update Service

6GK1704-1LW00-3AL0

For 1 year with automatic extension;
requirement: current software version
Upgrade
• From Edition 2006 to
Edition 2008 or V8.1
• From V6.0, V6.1, V6.2 or V6.3 to
Edition 2008 or V8.1

6GK1704-1LW00-3AE0
6GK1704-1LW00-3AE1

Siemens ST 80 / ST PC · 2013

5/197

© Siemens AG 2013

PC-based Automation
Communication — Industrial Ethernet
SOFTNET-IE RNA

■ Overview

■ Ordering data

Order No.

SOFTNET-IE RNA
Software for connecting PCs to
PRP-enabled networks with integrated SNMP, runtime software,
software and electronic manual on
CD-ROM, license key on USB flash
drive, Class A
SOFTNET-IE RNA V8.1
For 32-bit Windows XP;
German/English
• Single License for one installation

6GK1711-1EW08-1AA0

SOFTNET-IE RNA V8.2

• SOFTNET-IE RNA (Redundant Network Access is the software
for connecting a PC to networks with PRP (Parallel Redundancy Protocol in accordance with IEC62439-3) capability
• High level of plant availability thanks to duplicate transmission
of frames in two parallel, separate networks
• Reconfiguration times in a subnetwork do not affect the propogation time because the frames are transmitted via two
separate networks (bumpless redundancy)
• Integration in network management systems through support
for SNMP
• Configuring tools are included in the scope of delivery of the
communication software in each case

Industrial
Ethernet
(LAN A)
Industrial
Ethernet
(LAN B)
SIPROTEC

SIMATIC
S7-400 with
CP 443-1RNA

5/198

Siemens ST 80 / ST PC · 2013

SCALANCE
X204RNA

PC
G_IK10_XX_10333

5

Server with
SOFTNET-IE
RNA

PG/PC/IPC with
SOFTNET-IE RNA

For 32/64-bit
Windows 7 Professional/Ultimate;
for 64-bit Windows 2008 Server R2;
German/English
• Single License for one installation

6GK1711-1EW08-2AA0

Software Update Service

6GK1711-1EW00-3AL0

For 1 year with automatic extension;
requirement: current software
version
SCALANCE X-200RNA
Industrial Ethernet
network access points
Industrial Ethernet network access
points with integrated SNMP
access, web diagnostics and
PROFINET diagnostics, for connecting non-PRP-enabled terminal
equipment to PRP networks; incl.
operating instructions, Industrial
Ethernet network manual and configuration software on CD-ROM;
with electrical and optical ports for
glass multimode fiber-optic cable
up to 5 km
• SCALANCE X204RNA
with four 100 Mbit/s RJ45 ports
• SCALANCE X204RNA EEC
with two 100 Mbit/s RJ45 ports and
two RJ45/SFP combo ports

6GK5204-0BA00-2KB2
6GK5204-0BS00-3LA3

© Siemens AG 2013

PC-based Automation
Communication — Industrial Ethernet
SOFTNET PN IO

■ Overview

SIMATIC NET
OPC-Scout

PC/IPC with
SOFTNET PN IO

WinCC
OPC-Client

OPC UA

Microsoft Office
OPC-Client

OPC XML
Webclient

COM/DCOM

Internet
Intranet

OPC XML DA
as Webservice

PN IO OPC-Server

PROFINET
Communication
SOFTNET PN IO
PROFINET
Industrial Ethernet
IE/PB Link
PN IO
ET 200pro
ET 200S with
IM 151-3 PN

G_IK10_XX_10073

PROFIBUS

e.g. S7-300 with
CPU 31x and
CP 343-1

e. g. S7-300 with
CP 342-5 as Slave
ET 200S

PC with SOFTNET PN IO as PROFINET IO Controller

7&3
8'3

31

053

23&

3*23 66

,7
*B,.B;;B

,62

• Software with PROFINET IO Controller function for coupling
PG/PC and IPC with PROFINET IO Devices
• Possible applications:
- PC-based control systems
- HMI systems
- Test applications
• Communication services:
- PROFINET IO Controller
• Can be used with
- Integrated interfaces of SIMATIC PG/PC
- You can find more information about the environment of use
at www.siemens.com/simatic-net/ik-info
• Cost-effective solution for the low-end performance range
• OPC server for I/O interfacing over PROFINET included in
scope of supply

Siemens ST 80 / ST PC · 2013

5/199

5

© Siemens AG 2013

PC-based Automation
Communication — Industrial Ethernet
SOFTNET PN IO

■ Ordering data

Order No.

Order No.

SOFTNET PN IO

Software Update Service

Software for PROFINET IO Controller
with OPC server and NCM PC,
runtime software, software and
electronic manual on CD-ROM,
license key on USB flash drive,
Class A

For 1 year with automatic extension;
requirement: current software
version
Upgrade
• From Edition 2006 to
SOFTNET PN IO
Edition 2008 or V8.1
• From V6.0, V6.1, V6.2 or
V6.3 to SOFTNET PN IO
Edition 2008 or V8.1

SOFTNET-IE PN IO V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit: Windows 2008 Server R2
German/English
• Single License for one installation

6GK1704-1HW08-2AA0

SOFTNET PN IO Edition 2008
(V7.1)
For 32-bit
Windows XP Professional SP 2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/
Ultimate SP1; Windows 2008 Server;
German/English
• Single License for one installation

6GK1704-1HW71-3AA0

5

5/200

Siemens ST 80 / ST PC · 2013

6GK1704-1HW00-3AL0

6GK1704-1HW00-3AE0

6GK1704-1HW00-3AE1

© Siemens AG 2013

PC-based Automation
Communication — Industrial Ethernet
OPC server for Industrial Ethernet

■ Overview
PC/Windows PC
SIMATIC NET
OPC-Scout

WinCC
OPC-Client

Microsoft Office
OPC-Client

OPC XML
Webclient

OPC UA
COM/DCOM

DP OPC server
FMS OPC server

S7 OPC server

Internet
Intranet

S/R OPC server

PN IO OPC server

SNMP
OPC server
OPC XML DA
as Web service

DP protocol
FMS protocol

S7 communication

Open
communication
(SEND/RECEIVE)

PROFINET

SNMP

PROFINET
Industrial Ethernet

S7-1200

S7-1200

PC
S7-400

S7-300
SIMATIC S5
(SEND/RECEIVE only)

ET 200pro

5
PC

PROFIBUS

G_IK10_XX 10103

SIMATIC S5

System integration with OPC server

OPC (Openness, Productivity & Collaboration) is a
standardized, open, and vendor-independent interface that is
widely used in automation.
A fundamental distinction is made between the classic OPC and
its consistent further development OPC UA (Unified Architecture). Smooth migration to the new OPC UA standard is easily
possible; this offers further value added, such as security. The
SIMATIC NET OPC servers offer the two interfaces OPC UA and
classic OPC for SIMATIC S7 and PROFINET.
• The appropriate OPC servers are included in the scope of
supply of the respective communication software
• Standardized, open multi-vendor interface
• It permits interfacing of OPC-capable Windows
applications to S7-communication, open communication
(SEND/RECEIVE), PROFINET and SNMP.
• Increased availability thanks to additional option packages
such as OPC server redundancy
• OPC Scout with browser functionality as an OPC client and
OCX Data Control/.NET Data Control for simple OPC client
creation

Siemens ST 80 / ST PC · 2013

5/201

© Siemens AG 2013

PC-based Automation
Communication — Industrial Ethernet
OPC server for Industrial Ethernet

■ Ordering data
SNMP OPC server

Order No.
See SNMP OPC server

Status monitoring of SNMP-capable
devices in any OPC client systems;
e.g. SIMATIC WinCC/PCS 7

Order No.
S7 OPC Redundancy
Software for redundant OPC servers
in the environment of Industrial
Ethernet software, S7 products,
runtime software, software and electronic manual on CD-ROM, license
key on USB flash drive, Class A
S7 OPC Redundancy V8.2
For 64-bit:
Windows 2008 Server R2;
German/English
• Single License for one installation

6GK1706-1CW08-2AA0

Software Update Service

6GK1706-1CW00-3AL0

For 1 year with automatic extension;
requirement: current software
version

5

5/202

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
Communication — Industrial Ethernet
PN CBA OPC server

■ Overview

WinCC flexible
OPC client

SOFTNET-S7
SOFTNET-S7 Lean
S7-1613

Microsoft Office
OPC client

PN CBA OPC-Server

SIMATIC NET
OPC Scout

SOFTNET PN IO

S7-OPC-Server

PN CBA
OPC-Server

PN IO OPC-Server

S7 communication

PROFINET CBA

PROFINET IO

PROFINET
Industrial Ethernet
PROFINET
CBA
component

PROFINET
IO Devices
e.g. S7-300 with
CP 343-1 and
CP 343-5

ET 200pro

IE/PB
Link
PN IO

e.g. S7-400
with
CP 443-1 Advanced

ET 200S

PROFIBUS DP

S7-300 with
CP 343-1,
IPC with CP 343-1 Lean
CP 1616/ CP 343-1
CP 1604

ET 200S

PROFINET
IO Device

Data access
Data access via PROFIBUS DP
from viewpoint of PN CBA OPC server

5

PROFIBUS DP

ET 200S

from viewpoint of PN IO OPC server

G_IK10_XX_10122

PROFINET
CBA
component

System integration with the PN CBA OPC server

• Access to variables in PROFINET CBA components over the
OPC interface
• Use of the objects and symbols defined using the PROFINET
engineering tool SIMATIC iMap and STEP 7
• Adding PROFINET functionality to existing installations. This
enables it to be used in parallel with other communication
protocols such as S7 communication with SOFTNET-S7 for
Industrial Ethernet.
• OPC Scout as an OPC client with browser functions for the
variables of the PROFINET CBA components

Siemens ST 80 / ST PC · 2013

5/203

© Siemens AG 2013

PC-based Automation
Communication — Industrial Ethernet
PN CBA OPC server

■ Ordering data

Order No.

PROFINET OPC server for CBA;
runtime software, software and
electronic manual on CD-ROM,
license key on USB flash drive,
Class A,
for 32-bit
Windows XP Professional SP 2/3;
Windows 2003 Server R2, SP2;
German/English
• Single license for one installation
• Software Update Service for one
year,
with automatic extension;
requirement: Current software
version
• Upgrade from Edition 2006 and
higher to Edition 2008,
single license
• Upgrade from V6.0, V6.1, V6.2 or
V6.3 to Edition 2008,
Single License

6GK1706-0HB71-3AA0
6GK1706-0HB00-3AL0

6GK1706-0HB00-3AE0

6GK1706-0HB00-3AE1

Software iMap V3.0
for configuring
PROFINET CBA
Requirement:
Windows 2000 Prof. with Service
Pack 4 or later or Windows XP
Prof. with Service Pack 1 or later
or Windows 2003 Server
with Service Pack 1 or later;
on PG or PC with Pentium
processor, min. 1 GHz; STEP 7
V5.3 or later with Service Pack 3,
PN OPC Server V6.3 or later

5

Type of supply:
German, English with electronic
documentation
• Single license
• Software Update Service
• Upgrade to V3.0, single license

5/204

■ More information
http://www.siemens.com/cba

PN CBA OPC Server Edition 2008

6ES7820-0CC04-0YA5
6ES7820-0CC01-0YX2
6ES7820-0CC04-0YE5

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

PC-based Automation
Communication — Industrial Ethernet
S7 OPC Redundancy for Industrial Ethernet

■ Overview

■ Ordering data

OPC (Openness, Productivity & Collaboration) is a
standardized, open, and vendor-independent interface that is
widely used in automation. OPC UA (Unified Architecture) is the
result of consistent further development of this standard, offering
additional functions such as security or redundancy.
S7 OPC Redundancy is a software product compliant with the
OPC UA standard that enables the redundant configuration of
OPC UA servers to SIMATIC S7. The availability of automation
data to operator control and monitoring systems is guaranteed
thanks to the redundant use of OPC UA servers. This requires
neither additional cabling for synchronizing the redundant OPC
UA servers, nor additional programming overhead in the PC.
The OPC UA servers are synchronized via high-performance
Industrial Ethernet network access points at 10/100 and
1000 Mpbs. S7 OPC Redundancy represents an integrated
customer solution for all SIMATIC NET S7 SOFTNET and
HARDNET software products in the automation world.

Order No.

S7 OPC Redundancy
Software for redundant OPC servers
in the environment of Industrial
Ethernet software, S7 products,
runtime software, software and electronic manual on CD-ROM, license
key on USB flash drive, Class A
S7 OPC Redundancy V8.2 for
Industrial Ethernet
For 64-bit:
Windows 2008 Server R2;
German/English
• Single License for one installation

6GK1706-1CW08-2AA0

Software Update Service

6GK1706-1CW00-3AL0

For 1 year with automatic extension;
requirement: current software
version

HMI

Industrial Ethernet
S7 OPC redundancy

S7 OPC redundancy
OPC UA
synchronization

Station A

5

Station B

Industrial Ethernet

G_IK10_XX_10295

PROFIBUS

Siemens ST 80 / ST PC · 2013

5/205

© Siemens AG 2013

PC-based Automation
Communication — Industrial Ethernet
SNMP OPC server

■ Overview

Pumpstation Network

Pump Main

1GBit

Pump Old

■ Ordering data

Order No.

Order No.

SNMP OPC server

SNMP OPC Server Extended

Including MIB compiler; single
license for one installation of runtime
software; software and electronic
manual on CD-ROM; license key on
USB stick, Class A;

Administration of
up to 200 IP addresses
• Extended V8.2
for 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit: Windows 2008 Server
R2;
Single license for one installation
• Extended 2008 (V7.1)
for 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/Ultimate
SP1; Windows 2008 Server;
Single license for one installation

SNMP OPC Server Basic

5

S_IK10_XX_00004

Pump Substation 1

• Status monitoring of SNMP-capable devices in any OPC client
systems; e.g. SIMATIC WinCC/PCS 7
• Easy access to SNMP-capable devices over the
OPC interface
• Devices without SNMP agents can be monitored using the
ping mechanism
• Configuring with STEP 7 or NCM PC
• Ready-to-use SNMP diagnostics profiles for Siemens devices,
e.g. SCALANCE X/W
• Generation of any SNMP diagnostics profiles by means of the
integral MIB compiler
• Easy setup of the monitored devices with the help of an
autodiscovery function

Administration of
up to 20 IP addresses
• Basic V8.2
for 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2;
Single license for one installation
• Basic 2008 (V7.1)
for 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/Ultimate
SP1; Windows 2008 Server;
Single license for one installation
Software Update Service SNMP
OPC Server Basic

6GK1706-1NW08-2AA0

6GK1706-1NW71-3AA0

5/206

6GK1706-1NX71-3AA0

6GK1706-1NX00-3AL0

For 1 year with automatic extension;
requirement: current software
version
6GK1706-1NW00-3AL0

For 1 year with automatic extension;
requirement: current software version
Upgrade SNMP OPC Server Basic
• From Edition 2006 to
Edition 2008 or V8.1
• From V6.0, V6.1, V6.2 or V6.3 to
Edition 2008 or V8.1

Software Update Service SNMP
OPC Server Extended

6GK1706-1NX08-2AA0

Upgrade SNMP OPC Server
Extended
• From Edition 2006 to
Edition 2008 or V8.1
• From V6.0, V6.1, V6.2 or V6.3 to
Edition 2008 or V8.1

6GK1706-1NX00-3AE0
6GK1706-1NX00-3AE1

SNMP OPC Server Power Pack
6GK1706-1NW00-3AE0
6GK1706-1NW00-3AE1

Siemens ST 80 / ST PC · 2013

For upgrade from
SNM OPC Server Basic to
SNM OPC Server Extended
Power Pack V8.2

6GK1706-1NX08-2AC0

Power Pack Edition 2008 (V7.1)

6GK1706-1NX71-3AC0

© Siemens AG 2013

PC-based Automation
Communication — Industrial Ethernet
SINEMA server

■ Overview

■ Ordering data

Order No.

SINEMA Server Basic V12

SINEMA Server is a web-based network monitoring software that
significantly reduces the response time to communications
problems in industrial networks, and thus avoids downtimes and
saves costs.
• Simple operator input even for plant operators or service
personnel, to enable autonomous detection and correction of
communications problems
• Graphical representation of industrial networks
(automatic topology detection and layout)
• Standardized network documentation
(reports for inventory, availability and utilization)
• Simple operation via web browser or via an
HMI/SCADA application, without special IT knowledge
• Network data such as network topology and device information automatically saved to a database
• Low installation and maintenance costs, especially thanks to
the use of pre-installed industrial PCs (Microbox PC)
• High degree of flexibility for graphical representation thanks to
automatic and customizable topology views
• Monitoring can be adapted to devices and users

Network monitoring software for industrial Ethernet and PROFINET networks,
runtime software, software and electronic manual on DVD, license key on
USB flash memory;
software for installation on PC hardware with Windows 7 Ultimate/
Enterprise SP1 (32/64-bit),
Windows XP SP3 (32-bit) and
Windows Server 2008 R2 (64-bit);
English/German/French/Chinese.
Other languages possible on request.
• For 50 devices that
can be identified via IP address
• For 100 devices that
can be identified via IP address
• For 250 devices that
can be identified via IP address
• For 500 devices that
can be identified via IP address
Upgrade SINEMA Server V11 to V12

6GK1781-1BA12-0AA0
6GK1781-1DA12-0AA0
6GK1781-1JA12-0AA0
6GK1781-1TA12-0AA0
6GK1781-2AA12-0AA0

5

Siemens ST 80 / ST PC · 2013

5/207

© Siemens AG 2013

PC-based Automation
Communication — PROFIBUS
Connection options to SIMATIC IPCs

■ Overview
Embedded Systems

Windows XP Pro + SP3

Windows Server 2003 +
SP1/2

Windows Server 2003 R2 /
SP2

other operating systems

Field PG M3

SIMATIC IPC847C

SIMATIC IPC647C

SIMATIC IPC547C,
SIMATIC HMI IPC577D

SIMATIC IPC627C

SIMATIC IPC827C

SIMATIC IPC427C

Windows XP Embedded +
SP1/SP2/FP 2007

SIMATIC IPC427C

SIMATIC HMI IPC477C

SIMATIC HMI IPC677C

SIMATIC IPC627C

SIMATIC S7 modular
Embedded Controller

SIMATIC
Industrial PCs 3)

Vista Business /
Ultimate + SP1/2

Op.
sys.

Windows Server 2008 +
SP1/2

SIMATIC Industrial PC/
Field PG

Windows Server 2008 R2

Operating system environment of the
communication software
Windows 7 Professional /
Ultimate

Communication Communication
hardware
software

●
○

●
○

●
○

●
○

●
○

●
○

●
○

○

-

-

-

-

-

-

●
○

●
○

●
○

●
○

-

-

○5)

●

●

●

●

●

●

●

-

-

-

-

-

-

-

●

●

●

●

-

-

-

●

●

●

●

●

●

●

-

-

-

-

-

-

-

●

●

●

●

-

-

-

●
○

●
●
○

●
○

●
○

●
○

●
○

●
○

○

-

●
○

●
○

●
○

●
○

●
○

●
-

●
○

●
-

●
-

●
○

●
○

-

●

●

●

●

●

●

●

-

-

●

●

●

●

●

-

-

-

-

●

●

-

●

●

●

●

●

●

●

-

-

●

●

●

●

●

-

-

-

-

●

●

-

●
○

●
●
○

●
○

●
○

●
○

●
○

●
○

○

-

●
●4)
○

●
-

●
●
○

●
○4)
○

●
●
○

-

○

-

-

● ●
○4) ○4)
○4) ○4)

-

●

●

●

●

●

●

●

-

-

●4)

-

●

○4)

●

-

-

-

-

○4) ○4)

-

●

●

●

●

●

●

●

-

-

●

-

●

○

●

-

-

-

-

○

○

-

●
●
●
●
●
●
●
●
●
●
●
●
-

●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●

●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
-

●
●
●
●
●
●
●
●
●
-

●
●
●
●
●
●
●
●
●
-

●
●
●
●
●
●
●
●
●
-

●
●
●
●
●
●
●
●
●
-

-

●
●
●
●
●
●
●
●
●
●
●

●4)
●
●
●
●
●4)
●4)
●4)
●4)
●
●
●
●
○2)
○2)
○2)
○2)

●
●
●
●
●
●
●
●
○2)
○2)
○2)
○2)

●
●
●
●
●
●
●
●
●
●
●
●
●
-

○4)
●
●
●
●
○4)
○4)
○4)
○4)
●
●
●
●
○2)
○2)
○2)
○2)

●
●
●
●
●
●
●
●
●
●
●
●
●
○2)
○2)
○2)
○2)

●
●
●
●
○2)
○2)
○2)
○2)

●
●
●
●
●
●
●
●

●
●
●
●
○2)
○2)
○2)
○2)

●
●
●
●
●
●
●
●

○4)
●
●
●
●
○4)
○4)
○4)
○4)
●
●
●
●
○2)
○2)
○2)
○2)

○4)
●
●
●
●
○4)
○4)
○4)
○4)
●
●
●
●
○2)
○2)
○2)
○2)

●
●
●
●
-

•

suitable

CP with DP-Base

CP 5603
(PCI-104)

HARDNET-PB DP DK 1)
(DK-5613, DP-base)
HARDNET-PB DP
(DP-5613)
HARDNET-PB S7
(S7-5613)
S7 OPC Redundancy for
PROFIBUS
CP mit DP-Base

CP 5613 A2,
CP 5614 A2
(PCI 32 Bit)

HARDNET-PB DP DK 1)
(DK-5613, DP-base)
HARDNET-PB DP
(DP-5613)
HARDNET-PB S7
(S7-5613)
S7 OPC Redundancy for
PROFIBUS
CP with DP-Base

CP 5623,
CP 5624
(PCIe x1)

5

HARDNET-PB DP DK 1)
(DK-5613, DP-base)
HARDNET-PB DP
(DP-5613)
HARDNET-PB S7
(S7-5613)
S7 OPC Redundancy for
PROFIBUS
SOFTNET-PB DP

CP 5612
(PCI 32 Bit)

SOFTNET-PB DP Slave
SOFTNET-PB S7
S7 OPC Redundancy for
PROFIBUS
SOFTNET-PB DP

CP 5622
(PCIe x1)

SOFTNET-PB DP Slave
SOFTNET-PB S7
S7 OPC Redundancy for
PROFIBUS

CP 5512
(Cardbus 32 Bit)

SOFTNET-PB DP

CP 5711
(USB V2.0)

SOFTNET-PB DP

SOFTNET-PB DP Slave
SOFTNET-PB S7

SOFTNET-PB DP Slave
SOFTNET-PB S7
S7 OPC Redundancy for
PROFIBUS

SIMATIC PG/PC

SOFTNET-PB DP
SOFTNET-PB DP Slave
SOFTNET-PB S7
S7 OPC Redundancy for
PROFIBUS

1) In order to use these CPs in other operating system environments, it is required to port HARDNET DP Development Kits (DK-5613) into the respective
operating system. You can request the HARDNET DP DK in the Internet under
www.siemens.com/simatic-net/dk5613.
2) integrated PROFIBUS interface is optional
3) depending on available memory and processor performance there could be
restrictions
4) depending on the slots of the selected PC version
5) EM-PCI 104 expansion module is required

Siemens ST 80 / ST PC · 2013

4)

Notes
- Please always note the supplementary conditions for the specified SIMATIC NET products
that you can view on the Internet pages shown below.
- for further details on XP embedded, see
http://support.automation.siemens.com/WW/view/en/21661049
- further details on system requirements and operating environments can be found in the
Readme file of the communication products on the SIMATIC NET PC Software CD V8.1
- Updates and supplements to the catalog entries, as well as the above tables can be
viewed at http://www.siemens.com/simatic-net/ik-info

Connection options of PROFIBUS CPs to PG/PC
Note:
The operating systems listed refer exclusively to the communication
products specified!

5/208

4)

4)

4)

-

not suitable

○

suitable under
certain conditions

*B,.B;;B

CPs and software for Industrial Ethernet

For the actual operating system that is available and has been released,
please refer to the description of the corresponding IPC.

© Siemens AG 2013

PC-based Automation
Communication — PROFIBUS
CP 5603

■ Overview

■ Ordering data

Order No.

CP 5603
communications processor

6GK1560-3AA00

PCI-104 card for connection to
PROFIBUS incl. DP-Base software
with NCM PC; DP-RAM interface for
DP master or DP slave, incl. PG and
FDL protocols; single license for one
installation, runtime software,
software and electronic manual on
CD-ROM, Class A, for operating
system support see SIMATIC NET
software; German/English
Software Upgrade

6GK1561-3AA01-3AE0

For CP 5603, CP 5613 A2 and
CP 5623 to Edition 2008 or V8.1
CP 5603 Microbox Package

6GK1560-3AU00

For use of CP 5603 in
Microbox 420/427B/427C;
consisting of CP 5603 module and
Microbox expansion frame

'36

)06

23&

3*23

CP 5603 expansion rack

66
*B,.B;;B

'30

• PCI-104 interface card with own microprocessor for
connecting embedded systems with PCI-104 interface to
PROFIBUS at up to 12 Mbit/s
• Function compatible with CP 5613 A2
• Communication services:
- PROFIBUS DP master Class 1 and 2 or DP slave according
to IEC 61158/61784
- PG/OP communication with STEP 5 and STEP 7
- S7 communication with HARDNET-PB S7 software package
- Open communication (SEND/RECEIVE) based on the
FDL interface
- PROFIBUS FMS according to IEC 61158/61784 with
FMS-5613 software package
• Extensive diagnostics options for installation, commissioning
and operation of the module
• Event and filter mechanism for reducing the load on the host
CPU
• Multiprotocol operation and parallel operation of up to three
CPs
• The appropriate OPC server and configuration tools are
included in the scope of delivery of the respective communication software
• Linux-based development kit with driver sources for
integration into "non-Windows" environments

6GK1560-3AA00-0AU0

For use in Microbox 420/427B/427C
with mounting material
CP 5603 mEC Package

6GK1560-3AE00

For use of CP 5603
in SIMATIC S7-MEC;
consisting of CP 5603 and withdrawable unit for CP 5603 for installation in the EM PCI-104 expansion
module of the SIMATIC S7-MEC
CP 5603 insert plate

6GK1560-3AA00-0AE0

Metal plate with RS485 cutout
for inserting for the S7 modular
embedded controller
See http://www.siemens.com/
simatic-net/dk5613

HARDNET-PB DP
Development Kit
HARDNET-PB DP Development Kit
software for CP 5603, CP 5613,
CP 5613 A2, CP 5623, CP 5613 FO,
CP 5614, CP 5614 A2, CP 5624; for
integration into other operating system environments on systems with a
PCI slot

Siemens ST 80 / ST PC · 2013

5/209

5

© Siemens AG 2013

PC-based Automation
Communication — PROFIBUS
CP 5603

■ Ordering data

Order No.
Software Update Service

Software for DP, incl. PG and FDL
protocol, OPC server and NCM PC;
runtime software, software and electronic manual on CD-ROM, license
key on USB flash drive, Class A, for
CP 5603, CP 5613 A2, CP 5623,
CP 5614 A2, CP 5624;

For 1 year with automatic extension;
requirement: current software version
Upgrade
• From Edition 2006 or 2007
to S7-5613 Edition 2008 or
HARDNET-PB S7 V8.1
• From V6.0, V6.1, V6.2 or V6.3
to S7-5613 Edition 2008 or
HARDNET-PB S7 V8.1

HARDNET-PB DP V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single License for one installation

6GK1713-5DB08-2AA0

For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/
Ultimate SP1; Windows 2008 Server;
English/German
• Single License for one installation

6GK1713-5DB71-3AA0

Software Update Service

6GK1713-5DB00-3AL0

For 1 year with automatic extension;
requirement: current software version
Upgrade
• From Edition 2006 or 2007
to DP-5613 Edition 2008 or
HARDNET-PB DP V8.1
• From V6.0, V6.1, V6.2 or V6.3
to DP-5613 Edition 2008 or
HARDNET-PB DP V8.1

6GK1713-5DB00-3AE0

6GK1713-5DB00-3AE1

HARDNET-PB S7

6GK1713-5FB71-3AA0

Software Update Service

6GK1713-5FB00-3AL0

For 1 year with automatic extension;
requirement: current software version
Upgrade
• From Edition 2006 or 2007
to FMS-5613 Edition 2008
• From V6.0, V6.1, V6.2 or V6.3
to FMS-5613 Edition 2008

PROFIBUS FastConnect
bus connector
RS485 Plug 180

6GK1713-5FB00-3AE0
6GK1713-5FB00-3AE1
6XV1830-0EH10

6GK1500-0FC10

With 180° cable outlet,
insulation displacement
PROFIBUS bus terminal 12M
6GK1713-5CB08-2AA0

S7-5613 Edition 2008

6GK1713-5CB71-3AA0

You can find the HARDNET-PB DP Development Kit on the
Internet at:
http://www.siemens.com/simatic-net/dk5613

Siemens ST 80 / ST PC · 2013

6GK1500-0AA10

Bus terminal for connection of
PROFIBUS stations up to 12 Mbit/s
with plug-in cable 1.5 m long
PROFIBUS FastConnect
Stripping Tool

■ More information

5/210

6GK1713-5CB00-3AE1

Standard type with special design
for quick assembly, 2-core,
shielded,
sold in meters;
delivery unit max. 1000 m,
minimum order 20 m

HARDNET-PB S7 V8.2

For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/
Ultimate SP1; Windows 2008 Server;
English/German
• Single License for one installation

6GK1713-5CB00-3AE0

Software for FMS protocol incl.
PG/OP communication; FDL,
FMS-OPC server and NCM PC;
runtime software, software and electronic manual on USB stick, Class A,
for 32-bit Windows XP Professional
SP2/3; Windows 2003 Server R2,
SP2; Windows Vista Business/
Ultimate SP1; Windows 2008 Server;
for CP 5603, CP 5613, CP 5613 A2,
CP 5623, CP 5613 FO, CP 5614,
CP 5614 A2, CP 5624;
German/English
• Single License for one installation

PROFIBUS FC Standard Cable GP

Software for S7 communication, incl.
PG and FDL protocol, OPC server
and NCM PC; runtime software,
software and electronic manual on
USB flash drive, Class A, for
CP 5603, CP 5613 A2, CP 5623,
CP 5614 A2, CP 5624;

For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single License for one installation

6GK1713-5CB00-3AL0

FMS-5613 Edition 2008

DP-5613 Edition 2008

5

Order No.

HARDNET-PB DP

Preset stripping tool for fast
stripping of PROFIBUS FastConnect
bus cables

6GK1905-6AA00

© Siemens AG 2013

PC-based Automation
Communication — PROFIBUS
CP 5613 A2

■ Overview

■ Ordering data

Order No.

CP 5613 A2
communications processor

6GK1561-3AA01

PCI card (32-bit; 3.3 V/5 V) for
connection to PROFIBUS incl.
DP-Base software with NCM PC;
DP-RAM interface for DP master,
incl. PG and FDL protocols; single
license for one installation, runtime
software, software and electronic
manual on CD-ROM, Class A,
for operating system support
see SIMATIC NET software;
German/English
Software Upgrade

6GK1561-3AA01-3AE0

For CP 5603, CP 5613 A2 and
CP 5623 to Edition 2008 or V8.1
See http://www.siemens.com/
simatic-net/dk5613

HARDNET-PB DP
Development Kit

'36

)06

23&

3*23

66
*B,.B;;B

'30

• PCI card (universal keyed 5 V/3.3 V) with own microprocessor
for connection of PCs and SIMATIC PG/PC to PROFIBUS at up
to 12 Mbit/s
• Communication services:
- PROFIBUS DP master according to IEC 61158/61784 on a
PCI card
- PG/OP communication with STEP 5 and STEP 7
- S7 communication with HARDNET-PB S7 software package
- Open communication (SEND/RECEIVE) based on the
FDL interface
- PROFIBUS FMS according to IEC 61158/61784 with
FMS-5613 software package
• Comprehensive diagnostics possibilities for installation,
commissioning and operation of the module
• High performance over direct dual-port RAM access
• Event and filter mechanisms to reduce the loading on the host
CPU
• Multiprotocol operation and parallel operation of up to four
CPs
• Implementation in Motion Control applications is possible
because a constant bus cycle time is supported
• The appropriate OPC servers and configuration tools are
included in the scope of supply of the respective communications software.

HARDNET-PB DP Development Kit
software for CP 5613/CP 5614/
CP 5613 A2/CP 5614 A2/
CP 5613 FO for integration into
other operating system environments on systems with a PCI slot
HARDNET-PB DP
Software for DP, incl. PG and FDL
protocol, OPC server and NCM PC;
runtime software, software and electronic manual on CD-ROM, license
key on USB flash drive, Class A, for
CP 5603, CP 5613 A2, CP 5623,
CP 5614 A2, CP 5624;
HARDNET-PB DP V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single License for one installation

5

6GK1713-5DB08-2AA0

DP-5613 Edition 2008
For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/Ultimate
SP1; Windows 2008 Server;
English/German
• Single License for one installation

6GK1713-5DB71-3AA0

Software Update Service

6GK1713-5DB00-3AL0

For 1 year with automatic extension;
requirement: current software version
Upgrade
• From Edition 2006 or 2007 to
DP-5613 Edition 2008 or
HARDNET-PB DP V8.1
• From V6.0, V6.1, V6.2 or V6.3 to
DP-5613 Edition 2008 or
HARDNET-PB DP V8.1

6GK1713-5DB00-3AE0

6GK1713-5DB00-3AE1

Siemens ST 80 / ST PC · 2013

5/211

© Siemens AG 2013

PC-based Automation
Communication — PROFIBUS
CP 5613 A2

■ Ordering data

Order No.
Software Update Service

Software for S7 communication, incl.
PG and FDL protocol, OPC server
and NCM PC; runtime software,
software and electronic manual
on USB flash drive, Class A, for
CP 5603, CP 5613 A2, CP 5623,
CP 5614 A2, CP 5624;

For 1 year with automatic extension;
requirement: current software
version
Upgrade
• From Edition 2006 or 2007
to FMS-5613 Edition 2008
• From V6.0, V6.1, V6.2 or V6.3
to FMS-5613 Edition 2008

HARDNET-PB S7 V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single License for one installation

PROFIBUS FC Standard Cable GP

6GK1713-5CB08-2AA0

S7-5613 Edition 2008

6GK1713-5CB71-3AA0

PROFIBUS bus terminal 12M

Software Update Service

6GK1713-5CB00-3AL0

Bus terminal for connection of
PROFIBUS stations up to 12 Mbit/s
with plug-in cable 1.5 m long

Upgrade
• From Edition 2006 or 2007 to
S7-5613 Edition 2008 or
HARDNET-PB S7 V8.1
• From V6.0, V6.1, V6.2 or V6.3 to
S7-5613 Edition 2008 or
HARDNET-PB S7 V8.1

PROFIBUS FastConnect
bus connector
RS485 Plug 180

PROFIBUS FastConnect
Stripping Tool
6GK1713-5CB00-3AE0

6GK1713-5CB00-3AE1

6GK1713-5FB71-3AA0

■ More information
You can find the HARDNET-PB DP Development Kit on the
Internet.
You will find more information on the Internet at:
http://www.siemens.com/simatic-net/dk5613
The CP 5613 A2 module can also be used under the LINUX and
UNIX operating systems. Information on the available LINUX
distributors and UNIX operating systems can be found at:
www.siemens.com/simatic-net/ik-info

5/212

6GK1713-5FB00-3AE0
6GK1713-5FB00-3AE1
6XV1830-0EH10

6GK1500-0FC10

With 180° cable outlet, insulation
displacement

FMS-5613 Edition 2008
Software for FMS protocol, including
PG/OP communication, FDL,
FMS-OPC server and NCM PC;
runtime software, software and electronic manual on USB flash drive,
Class A for 32-bit Windows XP
Professional SP2/3, Windows 2003
Server R2, SP2, Windows Vista
Business/Ultimate SP1;
Windows 2008 Server; for CP 5613,
CP 5613 A2, CP 5613 FO, CP 5614,
CP 5614 A2; German/English
• Single License for one installation

6GK1713-5FB00-3AL0

Standard type with special design
for quick assembly, 2-core,
shielded,
sold in meters;
delivery unit max. 1000 m,
minimum order 20 m

For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/Ultimate
SP1; Windows 2008 Server;
English/German
• Single License for one installation

For 1 year with automatic extension;
requirement: current software
version

5

Order No.

HARDNET-PB S7

Siemens ST 80 / ST PC · 2013

Preset stripping tool for fast
stripping of PROFIBUS FastConnect
bus cables

6GK1500-0AA10

6GK1905-6AA00

© Siemens AG 2013

PC-based Automation
Communication — PROFIBUS
CP 5614 A2

■ Overview

■ Ordering data

Order No.

CP 5614 A2
communications processor

6GK1561-4AA01

PCI card (32-bit; 3.3 V/5 V) master and
slave connection to PROFIBUS
incl. DP-Base software with NCM PC;
DP-RAM interface for DP master, incl.
PG and FDL protocols; single license
for one installation, runtime software,
software and electronic manual on
CD-ROM, Class A, for operating
system support see SIMATIC NET
software;
German/English
Software Upgrade

6GK1561-3AA01-3AE0

For CP 5614 A2 and CP 5624 to
Edition 2008 or V8.1
HARDNET-PB DP Development Kit

'36

)06

23&

3*23

66
*B,.B;;B

'30

• PCI card (universal keyed 5 V/3.3 V) with own microprocessor
for connection of PCs and SIMATIC PG/PC to PROFIBUS at up
to 12 Mbit/s
• Communication services:
- PROFIBUS DP master and slave interface according to
IEC 61158/61784 on one PCI card
- PG/OP communication with STEP 5 and STEP 7
- S7 communication with HARDNET-PB S7 software package
- Open communication (SEND/RECEIVE) based on the
FDL interface
- PROFIBUS FMS according to IEC 61158/61784 with
FMS-5613 software package
• Comprehensive diagnostics possibilities for installation,
commissioning and operation of the module
• High performance over direct dual-port RAM access
• Event and filter mechanisms to reduce the loading on the host
CPU
• Multiprotocol operation and parallel operation of up to four
CPs
• Implementation of Motion Control applications is possible
because a constant bus cycle time is supported
• The appropriate OPC servers and configuration tools are
included in the scope of supply of the respective communications software.

See http://www.siemens.com/
simatic-net/dk5613

HARDNET-PB DP Development Kit
software for CP 5613/CP 5614/
CP 5613 A2/CP 5614 A2/ CP 5613 FO
for integration into other operating
system environments on systems with
a PCI slot
HARDNET-PB DP
Software for DP, incl. PG and
FDL protocol, OPC server and
NCM PC; runtime software, software
and electronic manual on CD-ROM,
license key on USB flash drive,
Class A, for CP 5603, CP 5613 A2,
CP 5623, CP 5614, CP 5614 A2,
CP 5624;
HARDNET-PB DP V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single License for one installation

5

6GK1713-5DB08-2AA0

DP-5613 Edition 2008
For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/Ultimate SP1;
Windows 2008 Server;
English/German
• Single License for one installation

6GK1713-5DB71-3AA0

Software Update Service

6GK1713-5DB00-3AL0

For 1 year with automatic extension;
requirement: current software version
Upgrade
• From Edition 2006 or 2007 to
DP-5613 Edition 2008 or
HARDNET-PB DP V8.1
• From V6.0, V6.1, V6.2 or V6.3 to
DP-5613 Edition 2008 or
HARDNET-PB DP V8.1

6GK1713-5DB00-3AE0

6GK1713-5DB00-3AE1

Siemens ST 80 / ST PC · 2013

5/213

© Siemens AG 2013

PC-based Automation
Communication — PROFIBUS
CP 5614 A2

■ Ordering data

Order No.
Software Update Service

Software for S7 communication, incl.
PG and FDL protocol, OPC server and
NCM PC; runtime software, software
and electronic manual on USB flash
drive, Class A, for CP 5603,
CP 5613 A2, CP 5623, CP 5614 A2,
CP 5624;

For 1 year with automatic extension;
requirement: current software version
Upgrade
• From Edition 2006 or 2007 to
FMS-5613 Edition 2008
• From V6.0, V6.1, V6.2 or V6.3 to
FMS-5613 Edition 2008

HARDNET-PB S7 V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single License for one installation

PROFIBUS FC Standard Cable GP

6GK1713-5CB08-2AA0

For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/Ultimate SP1;
Windows 2008 Server;
English/German
• Single License for one installation

Upgrade
• From Edition 2006 or 2007 to
S7-5613 Edition 2008 or
HARDNET-PB S7 V8.1
• From V6.0, V6.1, V6.2 or V6.3 to
S7-5613 Edition 2008 or
HARDNET-PB S7 V8.1

PROFIBUS bus terminal 12M
6GK1713-5CB71-3AA0

Bus terminal for connection of
PROFIBUS stations up to 12 Mbit/s
with plug-in cable 1.5 m long

6GK1713-5CB00-3AL0

PROFIBUS FastConnect
Stripping Tool

6GK1713-5CB00-3AE0

6GK1713-5CB00-3AE1

FMS-5613 Edition 2008
Software for FMS protocol,
including PG/OP communication, FDL,
FMS-OPC server and NCM PC; runtime software, software and electronic
manual on USB flash drive, Class A
for 32-bit Windows XP Professional
SP2/3, Windows 2003 Server R2, SP2,
Windows Vista Business/Ultimate SP1;
Windows 2008 Server; for CP 5613,
CP 5613 A2, CP 5613 FO, CP 5614,
CP 5614 A2,
German/English
• Single License for one installation

6GK1713-5FB71-3AA0

■ More information
You can find the HARDNET-PB DP Development Kit on the
Internet.
http://www.siemens.com/simatic-net/dk5613

5/214

6GK1713-5FB00-3AE0
6GK1713-5FB00-3AE1
6XV1830-0EH10

6GK1500-0FC10

With 180° cable outlet,
insulation displacement

Software Update Service
For 1 year with automatic extension;
requirement: current software version

6GK1713-5FB00-3AL0

Standard type with special design
for quick assembly, 2-core, shielded,
sold in meters;
delivery unit max. 1000 m,
minimum order 20 m
PROFIBUS FastConnect
bus connector
RS485 Plug 180

S7-5613 Edition 2008

5

Order No.

HARDNET-PB S7

Siemens ST 80 / ST PC · 2013

Preset stripping tool for fast stripping
of PROFIBUS FastConnect bus cables

6GK1500-0AA10

6GK1905-6AA00

© Siemens AG 2013

PC-based Automation
Communication — PROFIBUS
CP 5623

■ Overview

■ Ordering data

Order No.

CP 5623
communications processor

6GK1562-3AA00

PCI Express x1 card (32 bit) for
connection to PROFIBUS incl.
DP-Base software with NCM PC;
DP-RAM interface for DP master or
DP slave, incl. PG and FDL protocols; single license for one installation, runtime software, software and
electronic manual on CD-ROM,
Class A, for operating system support see SIMATIC NET software;
German/English
Software Upgrade

6GK1561-3AA01-3AE0

For CP 5603, CP 5613 A2 and
CP 5623 to Edition 2008 or V8.1
see http://www.siemens.com/
simatic-net/dk5613

HARDNET-PB DP
Development Kit

'36

)06

23&

3*23

66
*B,.B;;B

'30

• PCI Express card (PCIe x1) with own microprocessor for
connecting PCs and SIMATIC PG/PC to PROFIBUS at up to
12 Mbit/s
• Communication services:
- PROFIBUS DP master Class 1 and 2 or DP slave according
to IEC 61158/61784 on a PCI card
- PG/OP communication with STEP 5 and STEP 7
- S7 communication with HARDNET-PB S7 software package
- Open communication (SEND/RECEIVE) based on the
FDL interface
- PROFIBUS FMS according to IEC 61158/61784 with
FMS-5613 software package
• Extensive diagnostics options for installation, commissioning
and operation of the module
• Event and filter mechanism for reducing the load on the host
CPU
• Multiprotocol operation and parallel operation of up to four
CPs
• The appropriate OPC servers and configuration tools are
included in the scope of supply of the respective communication software

HARDNET-PB DP Development Kit
software for
CP 5603, CP 5613, CP 5613 A2,
CP 5623, CP 5613 FO, CP 5614,
CP 5614 A2, CP 5624;
for integration into other operating
system environments on systems
with a PCI or PCI Express slot
HARDNET-PB DP
Software for DP, incl. PG and
FDL protocol, OPC server and
NCM PC; runtime software, software
and electronic manual on CD-ROM,
license key on USB flash drive,
Class A, for CP 5603, CP 5613 A2,
CP 5623, CP 5614 A2, CP 5624;
HARDNET-PB DP V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single License for one installation

5
6GK1713-5DB08-2AA0

DP-5613, Edition 2008
For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
indows Vista Business/
Ultimate SP1; Windows 2008 Server;
English/German
• Single License for one installation

6GK1713-5DB71-3AA0

Software Update Service

6GK1713-5DB00-3AL0

For 1 year with automatic extension;
requirement: current software
version
Upgrade
• From Edition 2006 or 2007 to
DP-5613 Edition 2008 or
HARDNET-PB DP V8.1
• From V6.0, V6.1, V6.2 or V6.3 to
DP-5613 Edition 2008 or
HARDNET-PB DP V8.1

6GK1713-5DB00-3AE0

6GK1713-5DB00-3AE1

Siemens ST 80 / ST PC · 2013

5/215

© Siemens AG 2013

PC-based Automation
Communication — PROFIBUS
CP 5623

■ Ordering data

Order No.
Software Update Service

Software for S7 communication, incl.
PG and FDL protocol, OPC server
and NCM PC; runtime software,
software and electronic manual
on USB flash drive, Class A, for
CP 5603, CP 5613 A2, CP 5623,
CP 5614 A2, CP 5624;

For 1 year with automatic extension;
requirement: current software
version
Upgrade
• From Edition 2006 or 2007 to
FMS-5613 Edition 2008
• From V6.0, V6.1, V6.2 or V6.3 to
FMS-5613 Edition 2008

HARDNET-PB S7 V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single License for one installation

PROFIBUS FC Standard Cable GP

6GK1713-5CB08-2AA0

S7-5613 Edition 2008

6GK1713-5CB71-3AA0

PROFIBUS bus terminal 12M

Software Update Service

6GK1713-5CB00-3AL0

Bus terminal for connection of
PROFIBUS stations up to 12 Mbit/s
with plug-in cable 1.5 m long

Upgrade
• From Edition 2006 or 2007 to
S7-5613 Edition 2008 or
HARDNET-PB S7 V8.1
• From V6.0, V6.1, V6.2 or V6.3 to
S7-5613 Edition 2008 or
HARDNET-PB S7 V8.1

PROFIBUS FastConnect
bus connector
RS485 Plug 180

PROFIBUS FastConnect
Stripping Tool
6GK1713-5CB00-3AE0

6GK1713-5CB00-3AE1

6GK1713-5FB71-3AA0

■ More information
You can find the HARDNET-PB DP Development Kit on the
Internet.
You will find more information on the Internet at:
http://www.siemens.com/simatic-net/dk5613
The CP 5623 module can also be used under LINUX and UNIX
operating systems. Information on the available LINUX distributors and UNIX operating systems can be found at:
www.siemens.com/simatic-net/ik-info

5/216

6GK1713-5FB00-3AE0
6GK1713-5FB00-3AE1
6XV1830-0EH10

6GK1500-0FC10

With 180° cable outlet, insulation
displacement

FMS-5613 Edition 2008
Software for FMS protocol incl.
PG/OP communication; FDL,
FMS-OPC server and NCM PC;
runtime software, software and electronic manual on USB stick, Class A,
for 32-bit Windows XP Professional
SP2/3; Windows 2003 Server R2,
SP2; Windows Vista Business/
Ultimate SP1; Windows 2008 Server;
for CP 5603, CP 5613, CP 5613 A2,
CP 5623, CP 5613 FO, CP 5614,
CP 5614 A2, CP 5624;
German/English
• Single License for one installation

6GK1713-5FB00-3AL0

Standard type with special design
for quick assembly, 2-core,
shielded,
sold in meters;
delivery unit max. 1000 m,
minimum order 20 m

For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/
Ultimate SP1; Windows 2008 Server;
English/German
• Single License for one installation

For 1 year with automatic extension;
requirement: current software
version

5

Order No.

HARDNET-PB S7

Siemens ST 80 / ST PC · 2013

Preset stripping tool for fast
stripping of PROFIBUS FastConnect
bus cables

6GK1500-0AA10

6GK1905-6AA00

© Siemens AG 2013

PC-based Automation
Communication — PROFIBUS
CP 5624

■ Overview

■ Ordering data

Order No.

CP 5624 A2
communications processor

6GK1562-4AA00

PCI Express x1 card (32 bit) for master
and slave connection to PROFIBUS
incl. DP-Base software with NCM PC;
DP-RAM interface for DP master, incl.
PG and FDL protocols; single license
for one installation, runtime software,
software and electronic manual on
CD-ROM, Class A, for operating
system support see SIMATIC NET
software;
German/English
Software Upgrade

6GK1561-3AA01-3AE0

for CP 5614 A2 and CP 5624 to
Edition 2008 or V8.1
HARDNET-PB DP Development Kit

'36

)06

23&

3*23

66
*B,.B;;B

'30

• PCI Express card (PCIe x1) with own microprocessor for
connecting PCs and SIMATIC PG/PC to PROFIBUS at up to
12 Mbit/s
• Two 9-pin sub-D sockets for parallel operation as DP master
and DP slave
• Communication services:
- PROFIBUS DP master and slave interface according to
IEC 61158/61784 on one PCI card
- PG/OP communication with STEP 5 and STEP 7
- S7 communication with HARDNET-PB S7 software package
- Open communication (SEND/RECEIVE) based on the
FDL interface
- PROFIBUS FMS according to IEC 61158/61784 with
FMS-5613 software package
• Extensive diagnostics options for installation, commissioning
and operation of the module
• Event and filter mechanism for reducing the load on the host
CPU
• Multiprotocol operation and parallel operation of up to four
CPs
• The appropriate OPC servers and configuration tools are
included in the scope of supply of the respective communication software

HARDNET-PB DP Development Kit
software for
CP 5603, CP 5613, CP 5613 A2,
CP 5623, CP 5613 FO, CP 5614,
CP 5614 A2, CP 5624;
for integration into other operating
system environments on systems
with a PCI or PCI Express slot

see http://www.siemens.com/
simatic-net/dk5613

HARDNET-PB DP
Software for DP, incl. PG and
FDL protocol, OPC server and
NCM PC; runtime software, software
and electronic manual on CD-ROM,
license key on USB flash drive,
Class A, for CP 5603, CP 5613 A2,
CP 5623, CP 5614 A2, CP 5624;
HARDNET-PB DP V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single License for one installation

5

6GK1713-5DB08-2AA0

DP-5613, Edition 2008
For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/Ultimate SP1;
Windows 2008 Server;
English/German
• Single License for one installation

6GK1713-5DB71-3AA0

Software Update Service

6GK1713-5DB00-3AL0

For 1 year with automatic extension;
requirement: current software version
Upgrade
• From Edition 2006 or 2007 to
DP-5613 Edition 2008 or
HARDNET-PB DP V8.1
• From V6.0, V6.1, V6.2 or V6.3 to
DP-5613 Edition 2008 or
HARDNET DP V8.1

6GK1713-5DB00-3AE0

6GK1713-5DB00-3AE1

Siemens ST 80 / ST PC · 2013

5/217

© Siemens AG 2013

PC-based Automation
Communication — PROFIBUS
CP 5624

■ Ordering data

Order No.
FMS-5613 Edition 2008

Software for S7 communication, incl.
PG and FDL protocol, OPC server and
NCM PC; runtime software, software
and electronic manual on USB flash
drive, Class A, for CP 5603,
CP 5613 A2, CP 5623, CP 5614 A2,
CP 5624;

Software for FMS protocol incl.
PG/OP communication; FDL,
FMS-OPC server and NCM PC;
runtime software, software and
electronic manual on USB flash drive,
Class A, for 32-bit Windows XP
Professional SP2/3; Windows 2003
Server R2, SP2; Windows Vista
Business/Ultimate SP1; Windows 2008
Server; for CP 5603, CP 5613,
CP 5613 A2, CP 5623, CP 5613 FO,
CP 5614, CP 5614 A2, CP 5624;
German/English
• Single License for one installation

6GK1713-5FB71-3AA0

Software Update Service

6GK1713-5FB00-3AL0

HARDNET-PB S7 V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single License for one installation

6GK1713-5CB08-2AA0

S7-5613 Edition 2008

For 1 year with automatic extension;
requirement: current software version

For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/Ultimate SP1;
Windows 2008 Server;
English/German
• Single License for one installation

6GK1713-5CB71-3AA0

Software Update Service

6GK1713-5CB00-3AL0

For 1 year with automatic extension;
requirement: current software version
Upgrade
• From Edition 2006 or 2007 to
S7-5613 Edition 2008 or
HARDNET-PB S7 V8.1
• From V6.0, V6.1, V6.2 or V6.3 to
S7-5613 Edition 2008 or
HARDNET-PB S7 V8.1

5

Order No.

HARDNET-PB S7

PROFIBUS FastConnect
bus connector RS 485 Plug 180

6GK1713-5FB00-3AE0
6GK1713-5FB00-3AE1
6GK1500-0FC10

with 180° cable outlet
PROFIBUS bus terminal 12M
6GK1713-5CB00-3AE0

6GK1713-5CB00-3AE1

■ More information
You can find the HARDNET-PB DP Development Kit on the
Internet.
You can find more information on the Internet at:
http://www.siemens.com/simatic-net/dk5613

5/218

Upgrade
• From Edition 2006 or 2007 to
FMS-5613 Edition 2008
• From V6.0, V6.1, V6.2 or V6.3 to
FMS-5613 Edition 2008

Siemens ST 80 / ST PC · 2013

Bus terminal for connection of
PROFIBUS stations for up to 12 Mbit/s
with plug-in cable

6GK1500-0AA10

© Siemens AG 2013

PC-based Automation
Communication — PROFIBUS
CP 5512

■ Overview

■ Ordering data

Order No.

CP 5512
communications processor

6GK1551-2AA00

PC-Card (CardBus, 32-bit) for
connection of a programming
device or notebook to PROFIBUS or
MPI, under 32 bit in connection with
PROFIBUS SOFTNET software or
STEP 7;
German/English
SOFTNET-PB S7
Software for S7 communication, incl.
FDL protocol with OPC server and
NCM PC, runtime software, software
and electronic manual on CD-ROM,
license key on USB flash drive,
Class A; for CP 5512, CP 5611,
CP 5611 A2, CP 5612 (Win 7 and
higher), CP 5621, CP 5622
(Win 7 and higher), CP 5711;

'36

)06

23&

3*23

SOFTNET-PB S7 V8.2

66
*B,.B;;B

'30

• PC Card Type II (CardBus 32 bit) to connect PG/PC and
notebooks with PC card slot (CardBus 32 bit) to PROFIBUS
and to the MPI of the SIMATIC S7
• Communication services:
- PROFIBUS DP Master Class 1 incl. acyclic DP expansions
with SOFTNET-PB DP software package
- PROFIBUS DP Master Class 2 incl. acyclic DP expansions
with SOFTNET-PB DP software package
- PROFIBUS DP slave with SOFTNET-PB DP Slave software
package
- PG/OP communication with STEP 5 or STEP 7
- S7 communication with SOFTNET-PB S7 software package
- Open communication (SEND/RECEIVE on basis of the FDL
interface) with SOFTNET-PB DP or SOFTNET-PB S7 software
package
• Can be used with:
- STEP 7 and NCM PC; (ProTool, Micro/Win, ProTool/Pro,
SIMATIC PDM for PG/OP communication)
- SOFTNET-PB S7 (for S7 communication)
- SOFTNET-PB DP, SOFTNET-PB DP slave (for DP)
• The appropriate OPC servers are included in the scope of
supply of the respective communication software

for 32 Bit Windows 7 Professional/
Ultimate; English/German
• Single License for one installation

6GK1704-5CW08-2AA0

SOFTNET-S7 Edition 2008
for 32 Bit Windows XP Professional
SP2/3; Windows 2003 Server R2,
SP2; Windows Vista Business/
Ultimate SP1; Windows 2008 Server;
English/German
• Single License for one installation

6GK1704-5CW71-3AA0

Software Update Service

6GK1704-5CW00-3AL0

For 1 year with automatic extension;
requirement: current software
version
Upgrade
• From Edition 2006 to
SOFTNET-S7 Edition 2008 or V8.1
• From V6.0, V6.1, V6.2 or V6.3 to
SOFTNET-S7 Edition 2008 or V8.1

6GK1704-5CW00-3AE0

5

6GK1704-5CW00-3AE1

Siemens ST 80 / ST PC · 2013

5/219

© Siemens AG 2013

PC-based Automation
Communication — PROFIBUS
CP 5512

■ Ordering data

Order No.

Order No.

SOFTNET-PB DP

SOFTNET-PB DP slave

Software for DP protocol
(master class 1 and 2),
incl. FDL protocol with OPC server
and NCM PC,
runtime software, software and electronic manual on CD-ROM, license
key on USB flash drive; for CP 5512,
CP 5611, CP 5611 A2, CP 5612
(Win 7 and higher), CP 5621,
CP 5622 (Win 7 and higher),
CP 5711;

Software for DP slave, with DP OPC
server and NCM PC, single license
for one installation, runtime software,
software and electronic manual on
CD-ROM, license key on USB flash
drive, Class A; for CP 5512,
CP 5611, CP 5611 A2, CP 5612
(Win 7 and higher), CP 5621,
CP 5622 (Win 7 and higher),
CP 5711;
SOFTNET-PB DP Slave V8.2

SOFTNET-PB DP V8.2
for 32 Bit Windows 7 Professional/
Ultimate; English/German
• Single License for one installation

6GK1704-5DW08-2AA0

SOFTNET-DP Edition 2008 (V7.1)

6GK1704-5SW08-2AA0

SOFTNET-DP Slave Edition 2008
(V7.1)

for Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/Ultimate
SP1; Windows 2008 Server;
English/German
• Single License for one installation

6GK1704-5DW71-3AA0

Software Update Service

6GK1704-5DW00-3AL0

For 1 year with automatic extension;
requirement: current software
version
Upgrade
• From Edition 2006 to
SOFTNET-DP Edition 2008 or V8.1
• From V6.0, V6.1, V6.2 or V6.3 to
SOFTNET-DP Edition 2008 or V8.1

for 32/64-bit: Windows 7
Professional/Ultimate;
for 64-bit: Windows 2008 Server R2
German/English
• Single License for one installation

6GK1704-5DW00-3AE0
6GK1704-5DW00-3AE1

5

for 32 Bit Windows XP Professional
SP2/3; Windows 2003 Server R2,
SP2; Windows Vista Business/
Ultimate SP1; Windows 2008 Server;
English/German
• Single License for one installation

6GK1704-5SW71-3AA0

Software Update Service

6GK1704-5SW00-3AL0

For 1 year with automatic extension;
requirement: current software version
Upgrade
• From Edition 2006 to
SOFTNET-DP Slave Edition 2008
or V8.1
• From V6.0, V6.1, V6.2 or V6.3 to
SOFTNET-DP Slave Edition 2008
or V8.1
PROFIBUS FastConnect
bus connector
RS 485 Plug 180

6GK1704-5SW00-3AE0

6GK1704-5SW00-3AE1

6GK1500-0FC10

With 180° cable outlet
PROFIBUS adapter for CP 5512

5/220

Siemens ST 80 / ST PC · 2013

C79459-A1890-A10

© Siemens AG 2013

PC-based Automation
Communication — PROFIBUS
CP 5612

■ Overview

■ Ordering data

Order No.

CP 5612
communications processor
• PCI card (32-bit)
for connection of a programming
device or PC to PROFIBUS
• PCI card (32-bit)
CP 5612 and MPI cable, 5 m

6GK1561-2AA00

6GK1561-2AM00

SOFTNET-PB S7
Software for S7 communication, incl.
FDL protocol with OPC server and
NCM PC, runtime software, software
and electronic manual on CD-ROM,
license key on USB flash drive,
Class A; for CP 5512, CP 5611,
CP 5611 A2, CP 5612
(Win 7 and higher), CP 5621,
CP 5622 (Win 7 and higher),
CP 5711;
SOFTNET-PB S7 V8.2

'36

)06

23&

3*23

66
*B,.B;;B

'30

• PCI card (universal-keyed 5 V/3.3 V) for connecting PCs and
SIMATIC PG/PC to PROFIBUS at up to 12 Mbit/s and to the
MPI interface of SIMATIC S7
• Communication services:
- PROFIBUS DP Master Class 1 incl. acyclic DP expansions
with SOFTNET-PB DP software package
- PROFIBUS DP Master Class 2 incl. acyclic DP expansions
with SOFTNET-PB DP software package
- PROFIBUS DP slave with SOFTNET-PB DP Slave software
package
- PG/OP communication with STEP 7
- S7 communication with SOFTNET-PB S7 software package
- Open communication (SEND/RECEIVE on basis of the FDL
interface) with SOFTNET-PB DP or SOFTNET-PB S7 software
package
• Can be used with:
- STEP 7, STEP 7-Micro/Win, SIMATIC PDM
(for PG/OP communication)
- SOFTNET-PB S7 (for S7 communication)
- SOFTNET-PB DP, SOFTNET-PB DP slave (for DP)
• The appropriate OPC servers and configuration tools are
included in the scope of supply of the respective communications software.

For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single License for one installation

6GK1704-5CW08-2AA0

Software Update Service

6GK1704-5CW00-3AL0

For 1 year with automatic extension;
requirement: current software
version
Upgrade
• From Edition 2006 to
SOFTNET-S7 Edition 2008 or V8.1
• From V6.0, V6.1, V6.2 or V6.3 to
SOFTNET-S7 Edition 2008 or V8.1

6GK1704-5CW00-3AE0
6GK1704-5CW00-3AE1

SOFTNET-PB DP
Software for DP protocol
(master class 1 and 2), incl.
FDL protocol with OPC server and
NCM PC, runtime software, software
and electronic manual on CD-ROM,
license key on USB flash drive; for
CP 5611 A2, CP 5612
(Win 7 and higher), CP 5621,
CP 5622 (Win 7 and higher),
CP 5711;

5

SOFTNET-PB DP V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single License for one installation

6GK1704-5DW08-2AA0

Software Update Service

6GK1704-5DW00-3AL0

For 1 year with automatic extension;
requirement: current software
version
Upgrade
• From Edition 2006 to
SOFTNET-DP Edition 2008 or V8.1
• From V6.0, V6.1, V6.2 or V6.3 to
SOFTNET-DP Edition 2008 or V8.1

6GK1704-5DW00-3AE0
6GK1704-5DW00-3AE1

Siemens ST 80 / ST PC · 2013

5/221

© Siemens AG 2013

PC-based Automation
Communication — PROFIBUS
CP 5612

■ Ordering data

Order No.

Order No.

SOFTNET-PB DP slave

Software Update Service

Software for DP slave, with DP OPC
server and NCM PC, single license
for one installation, runtime software,
software and electronic manual on
CD-ROM, license key on USB flash
drive, Class A; for CP 5611 A2,
CP 5612 (Win 7 and higher),
CP 5621, CP 5622
(Win 7 and higher), CP 5711;

For 1 year with automatic extension;
requirement: current software
version
Upgrade
• From Edition 2006 to SOFTNET-DP
Slave Edition 2008 or V8.1
• From V6.0, V6.1, V6.2 or V6.3 to
SOFTNET-DP Slave Edition 2008
or V8.1

SOFTNET-PB DP Slave V8.2
for 32/64-bit: Windows 7
Professional/Ultimate;
for 64-bit: Windows 2008 Server R2
German/English
• Single License for one installation

PROFIBUS FastConnect
bus connector
RS 485 Plug 180

6GK1704-5SW00-3AE0
6GK1704-5SW00-3AE1

6GK1500-0FC10

With 180° cable outlet
6GK1704-5SW08-2AA0

PROFIBUS bus terminal 12M
Bus terminal for connection of
PROFIBUS stations for up to
12 Mbit/s with plug-in cable

5

5/222

6GK1704-5SW00-3AL0

Siemens ST 80 / ST PC · 2013

6GK1500-0AA10

© Siemens AG 2013

PC-based Automation
Communication — PROFIBUS
CP 5622

■ Overview

■ Ordering data

Order No.

CP 5622
communications processor
• PCI Express x1 card (32-bit)
for connection of a PG or PC
to PROFIBUS
• PCI Express x1 card (32-bit)
CP 5622 and MPI cable, 5 m

6GK1562-2AA00

6GK1562-2AM00

SOFTNET-PB S7
Software for S7 communication, incl.
FDL protocol with OPC server and
NCM PC, runtime software, software
and electronic manual on CD-ROM,
license key on USB flash drive,
Class A; for CP 5512, CP 5611,
CP 5611 A2, CP 5612
(Win 7 and higher), CP 5621,
CP 5622 (Win 7 and higher),
CP 5711;
SOFTNET-PB S7 V8.2

'36

)06

23&

3*23

66
*B,.B;;B

'30

• PCI Express card (PCIe x1) for connection of PCs and
SIMATIC PG/PC to PROFIBUS at up to 12 Mbit/s and to the
MPI of the SIMATIC S7
• Communication services:
- PROFIBUS DP Master Class 1 incl. acyclic DP expansions
with SOFTNET-PB DP software package
- PROFIBUS DP Master Class 2 incl. acyclic DP expansions
with SOFTNET-PB DP software package
- PROFIBUS DP slave with SOFTNET-PB DP Slave software
package
- PG/OP communication with STEP 7
- S7 communication with SOFTNET-PB S7 software package
- Open communication (SEND/RECEIVE on basis of the FDL
interface) with SOFTNET-PB DP or SOFTNET-PB S7 software
package
• Can be used with:
- STEP 7, STEP 7-Micro/Win, SIMATIC PDM
(for PG/OP communication)
- SOFTNET-PB S7 (for S7 communication)
- SOFTNET-PB DP, SOFTNET-PB DP slave (for DP)
• The appropriate OPC servers and configuration tools are
included in the scope of supply of the respective communications software.

For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single License for one installation

6GK1704-5CW08-2AA0

Software Update Service

6GK1704-5CW00-3AL0

For 1 year with automatic extension;
requirement: current software
version
Upgrade
• From Edition 2006 to
SOFTNET-S7 Edition 2008 or V8.1
• From V6.0, V6.1, V6.2 or V6.3 to
SOFTNET-S7 Edition 2008 or V8.1

6GK1704-5CW00-3AE0
6GK1704-5CW00-3AE1

SOFTNET-PB DP
Software for DP protocol
(master class 1 and 2), incl.
FDL protocol with OPC server and
NCM PC, runtime software, software
and electronic manual on CD-ROM,
license key on USB flash drive; for
CP 5611 A2, CP 5612
(Win 7 and higher), CP 5621,
CP 5622 (Win 7 and higher),
CP 5711;

5

SOFTNET-PB DP V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single License for one installation

6GK1704-5DW08-2AA0

Software Update Service

6GK1704-5DW00-3AL0

For 1 year with automatic extension;
requirement: current software version
Upgrade
• From Edition 2006 to
SOFTNET-DP Edition 2008 or V8.1
• From V6.0, V6.1, V6.2 or V6.3 to
SOFTNET-DP Edition 2008 or V8.1

6GK1704-5DW00-3AE0
6GK1704-5DW00-3AE1

Siemens ST 80 / ST PC · 2013

5/223

© Siemens AG 2013

PC-based Automation
Communication — PROFIBUS
CP 5622

■ Ordering data

Order No.

SOFTNET-PB DP slave
Software for DP slave, with DP OPC
server and NCM PC, single license
for one installation, runtime software,
software and electronic manual on
CD-ROM, license key on USB flash
drive, Class A; for CP 5611 A2,
CP 5612 (Win 7 and higher),
CP 5621, CP 5622
(Win 7 and higher), CP 5711;

PROFIBUS FastConnect
bus connector
RS 485 Plug 180

6GK1704-5SW00-3AE0
6GK1704-5SW00-3AE1

6GK1500-0FC10

With 180° cable outlet

SOFTNET-PB DP Slave V8.2

PROFIBUS bus terminal 12M

For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit: Windows 2008 Server R2
German/English
• Single License for one installation

6GK1704-5SW08-2AA0

Software Update Service

6GK1704-5SW00-3AL0

Bus terminal for connection of
PROFIBUS stations for up to
12 Mbit/s with plug-in cable

For 1 year with automatic extension;
requirement: current software
version

5

5/224

Order No.
Upgrade
• From Edition 2006 to SOFTNET-DP
Slave Edition 2008 or V8.1
• From V6.0, V6.1, V6.2 or V6.3 to
SOFTNET-DP Slave Edition 2008
or V8.1

Siemens ST 80 / ST PC · 2013

6GK1500-0AA10

© Siemens AG 2013

PC-based Automation
Communication — PROFIBUS
CP 5711

■ Overview

■ Ordering data

Order No.

CP 5711
communications processor
for connection of a programming
device or notebook to PROFIBUS or
MPI, under 32 bit in connection with
PROFIBUS SOFTNET software or
STEP 7;
German/English
• USB V2.0 adapter
• USB V2.0 adapter CP 5711 and
MPI cable, 5 m
Mounting rail support for CP 5711

6GK1571-1AA00
6GK1571-1AM00
6GK1571-1AA00-0AH0

Compartment for CP 5711
enclosure; fastened mechanically to
35 mm DIN rail
SOFTNET-PB S7

'36

)06

23&

3*23

66
*B,.B;;B

'30

Software for S7 communication, incl.
FDL protocol with OPC server and
NCM PC, runtime software, software
and electronic manual on CD-ROM,
license key on USB flash drive,
Class A; for CP 5611 A2, CP 5612
(Win 7 and higher), CP 5621,
CP 5622 (Win 7 and higher),
CP 5711;
SOFTNET-PB S7 V8.2

• USB adapter for the connection of PCs and SIMATIC PG/PC to
PROFIBUS DP or MPI via USB 2.0
• Operation in extended temperature range of -20 °C to +60 °C
• Active PROFIBUS termination to supply the PROFIBUS
network as end station of a segment
• Robust USB connection due to mechanical locking of the USB
connector to the CP 5711 enclosure
• Communication services:
- PROFIBUS DP master Class 1 and 2 according to
IEC 61158/61784 with SOFTNET-PB DP software package
- PROFIBUS DP slave with SOFTNET-PB DP Slave software
package
- PG/OP communication with STEP 5 or STEP 7 software
package
- S7 communication with SOFTNET-PB S7 software package
- Open communication (SEND/RECEIVE on basis of the FDL
interface) with SOFTNET-PB DP or SOFTNET-PB S7 software
package
• PROFIBUS connection with up to 12 Mbit/s
• Can be used with:
- STEP 7, STEP 7 Micro/WIN, WinCC/WinCC flexible,
NCM PC, SIMATIC PDM (for PG/OP communication)
- SOFTNET-PB S7 (for S7 communication)
- SOFTNET-PB DP, SOFTNET-PB DP slave (for DP)
• The appropriate OPC servers and configuration tools are
included in the scope of supply of the respective communication software

For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single License for one installation

6GK1704-5CW08-2AA0

SOFTNET-S7 Edition 2008 (V7.1)
For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/
Ultimate SP1; Windows 2008 Server;
English/German
• Single License for one installation

6GK1704-5CW71-3AA0

Software Update Service

6GK1704-5CW00-3AL0

5

For 1 year with automatic extension;
requirement: current software version
Upgrade
• From Edition 2006 to
SOFTNET-S7 Edition 2008 or V8.1
• From V6.0, V6.1, V6.2 or V6.3 to
SOFTNET-S7 Edition 2008 or V8.1

6GK1704-5CW00-3AE0
6GK1704-5CW00-3AE1

Siemens ST 80 / ST PC · 2013

5/225

© Siemens AG 2013

PC-based Automation
Communication — PROFIBUS
CP 5711

■ Ordering data

Order No.

Order No.

SOFTNET-PB DP

SOFTNET-PB DP slave

Software for DP protocol
(master class 1 and 2), incl.
FDL protocol with OPC server and
NCM PC, runtime software, software
and electronic manual on CD-ROM,
license key on USB flash drive;
for CP 5611 A2, CP 5612
(Win 7 and higher), CP 5621,
CP 5622 (Win 7 and higher),
CP 5711;

Software for DP slave, with DP OPC
server and NCM PC, single license
for one installation, runtime software,
software and electronic manual on
CD-ROM, license key on USB flash
drive, Class A; for CP 5611 A2,
CP 5612 (Win 7 and higher),
CP 5621, CP 5622
(Win 7 and higher), CP 5711;
SOFTNET-PB DP Slave V8.2

SOFTNET-PB DP V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single License for one installation

For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single License for one installation
6GK1704-5DW08-2AA0

SOFTNET-DP Edition 2008 (V7.1)
For Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/Ultimate
SP1; Windows 2008 Server;
English/German
• Single License for one installation

6GK1704-5DW71-3AA0

Software Update Service

6GK1704-5DW00-3AL0

For 1 year with automatic extension;
requirement: current software
version
Upgrade
• From Edition 2006 to
SOFTNET-DP Edition 2008 or V8.1
• From V6.0, V6.1, V6.2 or V6.3 to
SOFTNET-DP Edition 2008 or V8.1

For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/
Ultimate SP1; Windows 2008 Server;
English/German
• Single License for one installation

6GK1704-5SW71-3AA0

Software Update Service

6GK1704-5SW00-3AL0

For 1 year with automatic extension;
requirement: current software
version
6GK1704-5DW00-3AE0
6GK1704-5DW00-3AE1

5

Upgrade
• From Edition 2006 to SOFTNET-DP
Slave Edition 2008 or V8.1
• From V6.0, V6.1, V6.2 or V6.3 to
SOFTNET-DP Slave Edition 2008 or
V8.1
PROFIBUS FastConnect
bus connector
RS485 Plug 180
With 180° cable outlet

5/226

6GK1704-5SW08-2AA0

SOFTNET-DP Slave Edition 2008
(V7.1)

Siemens ST 80 / ST PC · 2013

6GK1704-5SW00-3AE0
6GK1704-5SW00-3AE1

6GK1500-0FC10

© Siemens AG 2013

PC-based Automation
Communication — PROFIBUS
SOFTNET for PROFIBUS

■ Overview

■ Ordering data

Order No.

SOFTNET-PB S7
Software for S7 communication, incl.
FDL protocol with OPC server and
NCM PC, runtime software, software
and electronic manual on CD-ROM,
license key on USB flash drive,
Class A; for CP 5611 A2, CP 5612
(Win 7 and higher), CP 5621,
CP 5622 (Win 7 and higher),
CP 5711;

PC/IPC with
CP 5612/
CP 5622/CP 5711
and SOFTNET for
PROFIBUS

PROFIBUS

SOFTNET-PB S7 V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single License for one installation

S7-1200 with
CM 1243-5

'36

)06

23&

3*23

66
*B,.B;;B

'30

S7-300 with CP 342-5 S7-400 with
or CP 343-5
CP 443-5

G_IK10_XX_50039

S5-115U to S5-155U
with CP 5431 FMS/DP

6GK1704-5CW08-2AA0

SOFTNET-S7 Edition 2008 (V7.1)

• Software for connecting PCs/programming devices and
notebooks to programmable controllers
• Communication services:
- PROFIBUS DP master Class 1 and 2 with acyclic expansions
- PROFIBUS DP slave
- PG/OP communication
- S7 communication
- Open communication (SEND/RECEIVE) based on the FDL
interface
• The corresponding OPC servers are included in the scope of
supply of the respective communication software
• Can be used with:
- CP 5512 (PC card, CardBus 32-bit)
- CP 5611 A2 and CP 5612 (PCI, 32-bit)
- CP 5612 (PCI, 32-bit)
- CP 5621 and CP 5622 (PCIe x1)
- CP 5622 (PCIe x1)
- CP 5711 (USB V2.0)
- Integrated PROFIBUS interfaces of SIMATIC PGs/PCs

For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/
Ultimate SP1; Windows 2008 Server;
English/German
• Single License for one installation

6GK1704-5CW71-3AA0

Software Update Service

6GK1704-5CW00-3AL0

For 1 year with automatic extension;
requirement: current software version
Upgrade
• From Edition 2006 to
SOFTNET-S7 Edition 2008 or V8.1
• From V6.0, V6.1, V6.2 or V6.3 to
SOFTNET-S7 Edition 2008 or V8.1

6GK1704-5CW00-3AE0
6GK1704-5CW00-3AE1

5

Siemens ST 80 / ST PC · 2013

5/227

© Siemens AG 2013

PC-based Automation
Communication — PROFIBUS
SOFTNET for PROFIBUS

■ Ordering data

Order No.

Order No.

SOFTNET-PB DP

SOFTNET-PB DP slave

Software for DP protocol
(master class 1 and 2), incl.
FDL protocol with OPC server and
NCM PC, runtime software, software
and electronic manual on CD-ROM,
license key on USB flash drive; for
CP 5611 A2, CP 5612
(Win 7 and higher), CP 5621,
CP 5622 (Win 7 and higher),
CP 5711;

Software for DP slave, with
DP OPC server and NCM PC,
single license for one installation,
runtime software, software and electronic manual on CD-ROM, license
key on USB flash drive, Class A; for
CP 5611 A2, CP 5612
(Win 7 and higher), CP 5621,
CP 5622 (Win 7 and higher),
CP 5711;

SOFTNET-PB DP V8.2

SOFTNET-PB DP Slave V8.2

For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single License for one installation

For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single License for one installation

6GK1704-5DW08-2AA0

SOFTNET-DP Edition 2008 (V7.1)
For Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/Ultimate
SP1; Windows 2008 Server;
English/German
• Single License for one installation

6GK1704-5DW71-3AA0

Software Update Service

6GK1704-5DW00-3AL0

For 1 year with automatic extension;
requirement: current software version
Upgrade
• From Edition 2006 to
SOFTNET-DP Edition 2008 or V8.1
• From V6.0, V6.1, V6.2 or V6.3 to
SOFTNET-DP Edition 2008 or V8.1

6GK1704-5DW00-3AE0
6GK1704-5DW00-3AE1

5

5/228

6GK1704-5SW08-2AA0

SOFTNET-DP Slave Edition 2008
(V7.1)

Siemens ST 80 / ST PC · 2013

For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/
Ultimate SP1; Windows 2008 Server;
English/German
• Single License for one installation

6GK1704-5SW71-3AA0

Software Update Service

6GK1704-5SW00-3AL0

For 1 year with automatic extension;
requirement: current software version
Upgrade
• From Edition 2006 to SOFTNET-DP
Slave Edition 2008 or V8.1
• From V6.0, V6.1, V6.2 or V6.3 to
SOFTNET-DP Slave Edition 2008
or V8.1

6GK1704-5SW00-3AE0
6GK1704-5SW00-3AE1

© Siemens AG 2013

PC-based Automation
Communication — PROFIBUS
OPC server for PROFIBUS

■ Overview
PC/Windows PC
SIMATIC NET
OPC-Scout

WinCC
OPC-Client

Microsoft Office
OPC-Client

OPC XML
Webclient

OPC UA
COM/DCOM

DP OPC server
FMS OPC server

DP protocol
FMS protocol

S7 OPC server

S7 communication

Internet
Intranet

S/R OPC server

Open
communication
(SEND/RECEIVE)

PN IO OPC server

PROFINET

SNMP
OPC server

OPC XML DA
as Web service

SNMP

PROFINET
Industrial Ethernet

S7-1200

SIMATIC S7-1200

PC
S7-400

S7-300
ET 200pro

SIMATIC S5
(SEND/RECEIVE only)

5
PC
PROFIBUS

G_IK10_XX 50700

SIMATIC S5

System integration with OPC server

• Standardized, open multi-vendor interface
• Interfacing of OPC-capable Windows applications to DP, FMS,
S7 communication and open communication
(SEND/RECEIVE) based on the FDL interface
• OPC Scout with browser functionality as an OPC client and
OCX-Data-Control/.NET Data Control for simple OPC client
creation
• The relevant OPC servers are supplied with each communication software package

Siemens ST 80 / ST PC · 2013

5/229

© Siemens AG 2013

PC-based Automation
Communication — PROFIBUS
S7 OPC Redundancy for PROFIBUS

■ Overview

■ Ordering data

OPC (Openness, Productivity & Collaboration) is a
standardized, open, and vendor-independent interface that is
widely used in automation. OPC UA (Unified Architecture) is the
result of consistent further development of this standard, offering
additional functions such as security or redundancy.
S7 OPC Redundancy is a software product compliant with the
OPC UA standard that enables the redundant configuration of
OPC UA servers to SIMATIC S7. The availability of automation
data to operator control and monitoring systems is guaranteed
thanks to the redundant use of OPC UA servers. This requires
neither additional cabling for synchronizing the redundant
OPC UA servers, nor additional programming overhead in the
PC. The OPC UA servers are synchronized via high-performance Industrial Ethernet network access points at 10/100 and
1000 Mpbs. S7 OPC Redundancy represents an integrated
customer solution for all SIMATIC NET S7 SOFTNET and
HARDNET software products in the automation world.

5

5/230

Siemens ST 80 / ST PC · 2013

Order No.

S7 OPC Redundancy
Software for redundant
OPC servers, Runtime software,
software and electronic manual on
CD-ROM, license key on USB stick,
Class A
S7 OPC Redundancy V8.2
for PROFIBUS
For 64-bit
Windows 2008 server R2;
English/German
• Single License for one installation

6GK1706-5CW08-2AA0

Software Update Service

6GK1706-5CW00-3AL0

For 1 year with automatic extension;
requirement: current software
version

6

© Siemens AG 2013

Customized Automation
6/2
6/2

Customized Automation
Introduction

6/4
6/4

Customized adaptations
Introduction

6/6
6/7

Customized hardware
Design products

6/10
6/11
6/13
6/14

OEM products
Flexible front design concept
for HMI products
MP 277 8" Touch control console
SIMATIC HMI Net Panel

6/17
6/18

Turnkey products
HMI operator stations

6/20
6/21
6/22
6/24

Customized software
Remote Operate Software
SIMATIC KNX/EIB2S7
S7 OpenModbusTCP

6/26

Examples of sector products

6/27
6/28
6/29

Renewable energy
Solar systems
Wind farms

6/30
6/30
6/32
6/33

Automotive industry
HMI operator stations
Front panel 15" with motion keys at side
Mobile Panel 277 10" Remote Operate

6/36
6/36

General machine construction
Front panel 15" Touch and Key
for Panel PCs, resistant to honing oil
Flat Panels, 10.4" for Panel PC

6/38
6/39

6/44
6/46
6/48

Food and beverages industry/
pharmaceuticals
Panels and Panel PCs
with stainless steel front
HMI Panels as rear-mounted devices
Flat Panels with stainless steel front
HMI stainless steel operator stations

6/49
6/50

Oil & gas/chemicals/shipbuilding
MP 377 15" Touch daylight readable

6/41

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Customized Automation
Introduction
Customized Automation

■ Overview

OEM products

Turnkey products

G_ST80_XX_00557

Software products and
customer-specific software images

Standard products
Design products

Customized Automation - Hardware

Customized Automation
Customized Hardware
Design products
OEM products
Turnkey products

Customized Software

Customized
Service & Support

SIMATIC standard products
SIMATIC controller
SIMATIC HMI

Customized Automation - overview

With Customized Automation, field-proven SIMATIC,
SIMATIC PC and SIMATIC HMI standards are transferred to
individual products and systems – tailored precisely to the
customer's requirements. The portfolio covers the hardware
and software range, as well as support and logistics.

6/2

Siemens ST 80 / ST PC · 2013

SIMATIC IPCs

Customized Logistics

G_ST80_XX_00441

6

© Siemens AG 2013

Customized Automation
Introduction
Customized Automation

■ Benefits
Time savings
• you can use comprehensive customization know-how and our
long years of experience with the SIMATIC components
• you do not have to build up any additional know-how, and you
can concentrate completely on your own core competence
Increase in profitability
• you invest your money and resources selectively in your core
competence
• you implement reliable material requirements and logistics
planning, tailored to your needs, thanks to our logistics
services
• you have maximum investment security thanks to maximum
quality, long-term availability and continuity with SIMATIC,
SIMATIC PC and SIMATIC HMI
• you save unnecessary costs thanks to tailor-made solutions,
and you benefit from the global service & support concepts
with SIMATIC, SIMATIC IPC, and SIMATIC HMI
Increase in competitive edge for the machine
• you use SIMATIC products that correspond to the highest
quality standards, offer optimal performance, and thus boost
your productivity by minimizing standstill times
• you receive customized products with Customized
Automation that fit outstandingly well into the "Totally
Integrated Automation" (TIA) concept
• you stand out not only for exceptional technology but also for
individual design of your machine, for example, by printing a
logo on the front of the enclosure.
Customized hardware:
Customized products are modified SIMATIC HMI standard
products. According to the necessary degree of modification of
the hardware, these types of product are separately identified
as:
• Design products
• OEM products
• Turnkey products

Customized software:
In the case of customer-specific products, the software can also
be individually installed. This includes the generation of
operating systems and also the integration and installation of
driver software and images – for complete, turnkey systems.
Customized software products:
• Remote Operate Software
for implementation of multi-user systems with HMI IPC and
clients on the basis of MP 377 and HMI IPC477
• SIMATIC KNX/EIB2S7
enables integration of actuators/sensors on a KNX/EIB bus of
building automation systems into SIMATIC S7
• Open MODBUS for SIMATIC systems
provides the capability of connecting systems from various
manufacturers to SIMATIC automation systems
Customized products from various industries
SIMATIC HMI products are provided with additional features in
order to facilitate optimum use in specific sectors of industry.
Stainless steel front panels for the food, beverages and tobacco
industry are one such example. With the exception of their front
panels, the devices are identical to standard products in respect
of function and technology.
We can offer products for the following industries:
• Renewable energy
• Automotive industry - HMI for factory automation
• General machine construction
• Food and beverages industry/pharmaceuticals
• Oil & gas/chemicals and shipbuilding
Customized products for various industries are developed and
produced in conjunction with a customized product agreement.

■ More information
More information is available in the Internet at
http://www.siemens.com/hmi-oem

The customer-specific modifications are available in all performance classes, starting with Push Button Panels or Key Panels,
Basic Panels, Comfort Panels up to Rack/Box/Panel PCs.

6

Siemens ST 80 / ST PC · 2013

6/3

© Siemens AG 2013

Customized Automation
Introduction
Customized adaptations

■ Application
Customized Software

Customized Logistics

Customized
Service & Support

Our SIMATIC IPC Customization Centers convert the fieldproven SIMATIC IPCs into individualized products and systems
for you – tailored precisely to your specific needs. Our portfolio
ranges from individualized design, through software installation
and special tests or certifications, right up to just-in-time
delivery. This provides you with more time for your own projects
while improving your profitability and thus your competitive
advantage.
Customized SIMATIC IPC precisely tailored to your requirements

■ Benefits
You gain time because you ...
• can benefit from our comprehensive customization expertise
and many years of experience regarding industrial PCs.
• do not have to create industrial computer-specific expertise
and can therefore fully concentrate on your core competencies.

6

You increase profitability because you ...
• invest your money and resources specifically in your core
competencies.
• implement a reliable inventory control and logistics planning
as required thanks to our logistics services.
• ensure maximum investment protection due to maximum
quality, long-term availability and continuity with SIMATIC IPC.
• avoid unnecessary costs due to custom-tailored solutions.
• benefit from worldwide Service & Support concepts with
SIMATIC IPC.
You increase your competitive edge because you ...
• use industrial PCs that conform to the highest quality
standards, offer optimum performance, and thus increase
productivity by minimizing downtimes.
• use customer-specific SIMATIC IPCs that are optimally
integrated in the Totally Integrated Automation (TIA) concept.
• not only stand out due to extraordinary technology, but also
due to the customized design of your machine, e.g. by
printing a logo on the device front of the industrial PC.

6/4

Siemens ST 80 / ST PC · 2013

Driver development
Image generation
Requirements
analysis, concept
development, solution
determination

Long-term availability
Demand-oriented
manufacturing
Individual labeling
Adaptable packaging
and delivery
Requirements
analysis, concept
development, solution
determination
Customized project
monitoring
Individual repair
concepts

G_ST80_XX_00558

■ Overview

Customized hardware Individual in design and configuration
Customized design
• Inscription or printed logo, e.g. on the front cover of the
enclosure, matches your corporate design requirements
• Custom color design of enclosure, individual enclosure
components, e.g. enclosure front and front cover – for perfect
optical integration of the PC in the operating environment
Customer-specific configuration
• Optimization of the computer configuration –
corresponding to the requirements of your application,
e.g. with or without PROFIBUS interfaces or optical drives
• Optimal selection of the required components - with regard
to performance capability, long-term availability and compatibility, e.g. processor, fan, work memory, etc.
• Installation of the hardware you specified – e.g. third-party
hardware such as drives and PC cards or customized,
supplied hardware
Customized software – operating systems, drivers, image
Generation of operating systems
• E.g. for Windows XP embedded,
• and the RMOS3 real-time operating system from Siemens
• For customer-specific preinstalled LINUX operating system1)
Integration and installation of driver software and image
storage
• E.g. for additional plug-in cards, controllers and memory
media
• For complete, turn-key systems
1)

Suitable for specific LINUX versions in accordance with the specifications
of the Siemens manufacturer's declaration "Suitable for LINUX", see
http://www.siemens.com/simatic-pc/suitable-for-linux

© Siemens AG 2013

Customized Automation
Introduction
Customized adaptations

■ Application (continued)
Customized service and support
Pre-sales and after-sales support
• Requirements analysis, concept creation, solution generation
• Competent project support from the offer through to delivery
and beyond
• Individual repair concepts with worldwide Siemens service
network with 190 branches and 33 repair centers
• 24-hour product support over the SIMATIC Hotline
System test of hardware and software, e.g.
• EMC chamber – Test for electromagnetic compatibility
• Thermal simulation – Thermal simulation and heat imaging
camera to detect heat pockets
• Heat test – Testing of all components in a 36-hour heat test at
40 degrees Celsius in a heated cabinet
• Stress test – Test for high vibration/shock loading, specially
for CPU, graphics, memory, modules, etc.
Product Equipment Data (PED)
• Online tool PED (www.siemens.com/ped) – For easy,
systematic identification and management of device components. It shows you the most important components of your
equipment (delivery status) easily and quickly and supports
you worldwide in the event of a servicing requirement with the
procurement of suitable replacement parts.

Individual logistics solutions
• Kanban delivery – We supply according to the requirements
of the organization units in the production process of our
customers who organize their production process control in
accordance with the Kanban principle. This shortens the
throughput time and reduces inventories.
• Just in time – We reduce the inventories and throughput
times of our customers by supplying the hardware manufactured customer specifically at exactly the time when they need
them in the production process or in the logistics chain
• Reusable packaging – Better than recycling!
The packaging is collected from our customers after the
specially manufactured hardware has been unpacked and
reused for transporting the next delivery. Packaging material
is saved to the advantage of our customers and the
environment.

■ More information
You can find further information at:
Internet: http://www.siemens.com/customized-pc
Email: customized-pc.automation@siemens.com

"Tempesting" (SITEMP)
• TEMPEST (Temporary emanation and spurious transmission) – For protecting compromising data from listening-in
attacks by means of electromagnetic radiation
• Series measurements and certification of special PC hardware
according to the standards of the German Institute for Safety
in Information Technology (BSI) for radiation safety
• E.g. PC for processing highly sensitive research and development data
Certification and approval of hardware and software –
e.g. UL and CE industry certification
On-site service – e.g. for plant failure, on-site repairs, product
upgrades
Customized logistics

6

Availability tailored to your requirements
• Configuration and design freeze – Individual availability
agreements for unchanged hardware and software versions of
the products (image compatibility)
• Replacement parts in centralized or decentralized spare
parts storage – For individually agreed periods or, where
applicable, last-time buying and storage of components
• License authorization for discontinued software, e.g. for
Microsoft operating systems such as Windows NT, MS DOS
Tailor-made right down to the detail
• Change notices – Individual agreements for customer information management, e.g. product discontinuation, version
updates, phase-out announcements
• Individual labeling – On the industrial PC and/or product
packaging, e.g. customized item/device/inventory numbers,
warehouse barcodes or packing and safety instructions
• Supply of accessories – e.g. adapter cables, keyboards or
accompanying documents and manuals

Siemens ST 80 / ST PC · 2013

6/5

© Siemens AG 2013

Customized Automation
Customized hardware
Customized hardware

■ Overview
For this purpose, we simply combine the standard components,
the customized components, and the additionally required
software function expansions into a SIMATIC OEM device, as
with a modular system.

Customized products are modified
SIMATIC HMI standard products
A distinction is made according to the degree of hardware
modification:
• Design products
• OEM products
• Turnkey products
The Open Platform Program is available for customized software
solutions.
With these possible modifications, products are planned for
special customer requirements in the various industries.
• Customized products from various sectors
Further information can be found on the Internet at:
http://www.siemens.com/hmi-oem
Proportion of customized modifications on the individual
product types:

Standard
Products

Design
Products

15%

OEM
Products

However, new OEM products can frequently be based on
already implemented OEM products for efficiency and cost
savings (see product examples). The end product is then represented as a customized modification of an existing OEM
product.

25%

Turnkey
Products

G_ST80_XX_00296

10%

Customized hardware:
Design products
Customized design means modifying the design and visual
impact of the SIMATIC, SIMATIC HMI and SIMATIC IPC products
for seamless adaptation into the customer's individual machine
and plant design and special operator philosophy.

6

The modification options are:
• Changing the company logo and and device type designation
• Changing the keyboard color scheme, the key labeling, or the
key symbols
• Changing the enclosure color (front frame)
Design products are fully compatible with the standard products
in technology and functionality, and can thus be fully integrated
into the Totally Integrated Automation environment. Identical
technology enables, for example, replacement using standard
devices in the event of a fault in case the machine or plant
supplier does not currently have a customized product in the
spare parts warehouse.
OEM products
Product modifications for OEM (Original Equipment Manufacturer) customers are suitable for individual, industrial automation
solutions that cannot be fulfilled with the help of standard
products, or can only be handled with design-modified panels.
OEM products are individual solutions based on SIMATIC
standard components. They are specified, offered, developed
and supplied individually in consultation with the customer.

6/6

Siemens ST 80 / ST PC · 2013

Modification options:
• Changes in the keyboard layout, key size/design and key
arrangement
• Freely definable front dimensions and mechanical components
• Integration into enclosure for desktop use or support arm
mounting
• Different processes and memory media
• Different display technologies, sizes and resolutions
• Distributed configuration
• Additional modules or interfaces
• Freely selectable Windows versions as operating systems,
pre-installed SIMATIC software packages

Our OEM devices are available in every performance class starting from OEM Push Button Panels, through Text Displays,
Touch and Operator Panels, right up to multifunctional platforms
(MPs) and PCs in rack/box/panel versions with extensive
changes to hardware, equipment and installed software.
Customized OEM products are developed and produced in
various stages in accordance with quality standards.
Turnkey products
Customized turnkey products are ready-to-install and ready-touse products from a single source that have been combined and
assembled to customer specifications and in accordance with
the specific technical requirements of HMI products. With the
turnkey products, the HMI products are tested and supplied,
e.g. as complete operator stations, that is, mounted and wired in
special enclosures, and installed with the specified software:
• Optimized HMI operator station: ergonomic, functional,
certified and tested
• Optimal mechanical installation of the devices with defined
high degree of protection
• Flexible in installation and wiring
• Variable mounting options
(support arm, stand, wall-mounting)
• Certified in accordance with VDE, CE and UL
(in accordance with agreements and statutory conditions)
• Vibration-tested and shock-tested
• Packaged for safe transport
• Tested heat balance with passive cooling and with specified
ambient temperature
• Customer-specific software suite with electronic software
release management
Customized SIMATIC turnkey products offer standard product
quality from a single source and are ready-to-install and readyto-use.

© Siemens AG 2013

Customized Automation
Customized hardware
Design products

■ Overview

The following applies for implementation in
Digital Express design:
• Without contractual obligation
• Even small ordering quantities
• Significantly reduced implementation time
• Photo-realistic print quality
The SIMATIC HMI products with customer-specific design are
completely identical to the standard products in respect of
technology and function. This similarity makes it possible to
respond flexibly to almost any need situation. In this way, a
machinery and plant supplier can quickly switch to standard
products if in the event of a fault there are no HMI design units
available in the spare parts inventory.
This flexible production makes cost-effective design products
possible even in small ordering quantities. The devices are
manufactured in the series production factory and are subject to
the same quality requirements as standard devices.
The professional creation of customized designs is handled by
the SIMATIC HMI Design Center.

SIMATIC HMI products in individual corporate design for
machines and plants are important for customers when making
purchasing decisions. Seamless integration of the HMI devices
in operation and ergonomics as well as in the overall machine
and plant design is especially important.
The HMI devices with customer-specific design fully meet these
requirements.
The following design changes are possible depending on the
variant:
• Extremely fast design implementations
• Implementation of even low minimum quantities
(no general agreements)
• Photo-realistic design up to 600 dpi
• Color gradients in the logo
The following changes (design variants) are possible:
• Version A:
Inserting the individual company logo instead of the
Siemens logo and changing the type designation
• Version B:
Version A + changing keyboard colors, key labels, symbols
and background color
• Version C:
Version B + changing the frame color for the front frame
• Digital Express design:
Version B in photo-realistic print quality, for small quantities
with accelerated execution of the project
The following applies for variants A-C:
• A contractually agreed minimum quantity per year is
necessary
• Stockpiling in accordance with contract
• First deliveries approximately 8 weeks after design start

The following services are offered to the customer:
• Support in the selection of suitable design variants
• Direct, specialist coordination and customer consultation in
the selection of appropriate typefaces, colors, and standard
symbols, e.g. to optimize machine operation
• Creation of a customer-specific design draft
• Short response times, first design draft around 5 days after
design start
• Obtaining required customer approval
There are no one-off project costs for these services of the
SIMATIC HMI Design Center (see "Additional information" for
details). A quotation will be made for any further changes and
consultation services.
Regarding customized design, it is also possible to match the
colors of various SIMATIC HMI design devices in order to
achieve a uniform corporate identity. The associated costs will
be calculated according to actual requirements.

■ Benefits
• Seamless adaptation to the customer's machine and plant
design and special operating philosophy
• No restrictions in ergonomics compared with a standard
product
• Even small quantities of design products may be ordered
• Replaceable and fully compatible with the standard devices in
terms of:
- Functions and interfaces
- SIMATIC HMI configuration software
- Enclosure and installation dimensions
- Logistics and service, identified repairs
• UL and CE certification, more upon request

Selected SIMATIC HMI Touch devices are available in Digital
Express design thanks to adapted production procedures.

Siemens ST 80 / ST PC · 2013

6/7

6

© Siemens AG 2013

Customized Automation
Customized hardware
Design products

■ Ordering data
According to
size of display

Device type

Order No. of
basic product

Minimum order
quantities
Normal design
Variant A/B

Minimum order quantities
per order
Express design

HMI TP700 Comfort

6AV2124-0GC01-0AX0

75

3

TP 177 6" DP mono

6AV6642-0BC01-1AX1

TP 177 6" DP/PN color

6AV6642-0BA01-1AX1

9 inch

HMI TP900 Comfort

6AV2124-0JC01-0AX0

75

3

12 inch

HMI TP1200 Comfort

6AV2124-0MC01-0AX0

50

3

MP 377 12" Touch

6AV6644-0AA01-2AX0

MP 277 10" Touch

6AV6643-0CD01-1AX1

HMI TP1500 Comfort

6AV2124-0QC02-0AX0

MP 377 15" Touch

6AV6644-0AB01-2AX0

HMI TP1500 Basic color PN

6AV6647-0AG11-3AX0

50

on request

19 inch

HMI TP1900 Comfort

6AV2124-0UC02-0AX0

50

on request

22 inch

HMI TP2200 Comfort

6AV2124-0XC02-0AX0

50

-

HMI KP8 PN, Key Panel

6AV3688-3AY36-0AX0

on request

on request

HMI KP8F PN

6AV3688-3AF37-0AX0

on request

on request

HMI KP300 Basic mono PN

6AV6647-0AH11-3AX0

200

on request

HMI KTP400 Comfort

6AV2124-2DC01-0AX0

100

on request

HMI KP400 Comfort

6AV2124-1DC01-0AX0

100

on request

HMI KTP400 Basic mono PN

6AV6647-0AA11-3AX0

200

on request

HMI KP700 Comfort

6AV2124-1GC01-0AX0

75

on request

HMI KTP600 Basic mono PN

6AV6647-0AB11-3AX0

200

on request

HMI KTP600 Basic color DP

6AV6647-0AC11-3AX0

200

on request

HMI KTP600 Basic color PN

6AV6647-0AD11-3AX0

200

on request

9 inch

HMI KP900 Comfort

6AV2124-1JC01-0AX0

75

on request

12 inch

HMI KP1200 Comfort

6AV2124-1MC01-0AX0

50

on request

HMI KTP1000 Basic color DP

6AV6647-0AE11-3AX0

75

on request

HMI KTP1000 Basic color PN

6AV6647-0AF11-3AX0

75

on request

HMI KP1500 Comfort

6AV2124-1QC02-0AX0

50

on request

Touchscreen
7 inch

15 inch

4
4

3
3
50

on request
3

Key
3 inch

4 inch

7 inch

15 inch

6

6/8

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Customized Automation
Customized hardware
Design products

■ Ordering data (continued)
According to
size of display

Device type

Order No. of
basic product

Minimum order
quantities
Normal design
Variant A/B

Minimum order quantities
per order
Express design

7 inch

IPC277D Touch

depending on the configuration

50

2

9 inch

IPC277D Touch

depending on the configuration

50

2

12 inch

Flat Panel Touch or Monitor

depending on the configuration

50

on request

IPC277D Touch

depending on the configuration

50

2

Panel PC Touch or Key

depending on the configuration

50

on request

ITC1200

6AV6646-1AA22-0AX0

75

on request

Flat Panel Touch or Monitor

depending on the configuration

50

on request

Flat Panel Touch PRO

6AV7861-5TB10-1BA0

50

on request

IPC277D Touch

depending on the configuration

30

on request

IPC477C Touch PRO

depending on the configuration

30

on request

IPC477C Touch

depending on the configuration

30

2

IPC677C Touch

depending on the configuration

30

2 (USB)

Panel PC Touch or Key

depending on the configuration

30

on request

ITC1500

6AV6646-1AB22-0AX0

30

on request

Flat Panel Touch or Monitor

depending on the configuration

30

on request

Flat Panel Touch PRO

6AV7861-6TB10-1BA0

30

on request

IPC477C Touch PRO

depending on the configuration

30

2

Panel PC Touch

depending on the configuration

30

on request

ITC1900

6AV6646-1AC22-0AX0

30

on request

ITC2200

6AV6646-1AD22-0AX0

30

on request

Touch/Monitor/Key

15 inch

19 inch

22 inch

For all other products not listed here, please inquire directly.

■ More information
Ordering information

Processing

Explanation of the tables with selection and order data:

A special order processing is required for the customized
design. Various approval steps by the customer are to ensure
that the end product meets the customer's expectations. The
orders are processed, like standard orders, via the Logistic
Center Nuremberg (LZN). Orders and deliveries of 1 unit or more
depending on the version or contract are possible!

"Device type" and "Order No. of the associated basic product"
• "Type specification" and "Order No." of the HMI standard
product to be modified.
• Start of delivery of a design variant cannot commence less
than 4 months after the start of delivery of a standard device.
"Design variant"
• Type of modification required, according to design variants
"Minimum quantity"
• In order to be able to offer high-quality products at a competitive price in the global market, there must be a lower limit to
the annual quantity and a minimum order quantity.
• The possible design devices with the associated minimum
quantities are listed in the overview tables.

6

Repairs/spare parts storage
Only identified repairs are carried out.
The customer-specific spare parts required for this purpose
(device front panels) are to be stored and made available by the
customer on expiry of the warranty period or on termination of
supply.
Contacts
Please contact your local/national SIMATIC HMI representative
(visit our Internet site for more information)

Prices and one-off costs

Further information can be found on the Internet at:

An additional amount over the price of the standard device is
charged for the customized design device.

http://www.siemens.com/hmi-oem

There are no additional costs for a one-off design
(without Change Requests).

Siemens ST 80 / ST PC · 2013

6/9

© Siemens AG 2013

Customized Automation
OEM products
OEM products

■ Overview

■ Benefits
• The SIMATIC HMI OEM concept represents "customizing at its
best":
Your requirements, based on sector and application knowhow, combined with our experience in the development of
HMI devices of all performance classes, result in tailor-made
solutions at a fair price.
• Customized OEM products are developed in defined stages
in accordance with quality standards and produced using
standard plant facilities - always in close cooperation with the
customer.
• Users in various industries, including regenerative energies,
the automotive industry, the food, beverages and tobacco
industries, the oil and gas industry, as well as in the plasticsprocessing industry and others are benefiting from our
experience of delivering tried and tested OEM versions and
industry standards.

6

• HMI product modifications for OEM customers are suitable for
complex industrial automation tasks that cannot be implemented using standard products.
• OEM devices are available in all performance classes: from
OEM Push Button Panels through Micro Panels, Panels and
Multi Panels right up to Panel PCs as well as Rack and Box
PCs - with far-reaching changes in hardware, equipment and
software.
• The following modifications are possible:
- Changes to keyboard layout: Number of keys,
key size/design and key layout
- Freely definable front dimensions and mechanical components
- A variety of processors for customized performance
- A variety of memory media and capacities
- Installation of function cards
- Display technologies, sizes and resolutions
- Options such as direct key modules
- Distributed configuration of Panel PCs
- Housings for desktop, stand or support-arm versions
(operator station concept)
- Additional modules or interfaces, of course always complete
with the necessary device drivers
- Selectable Windows operating systems
- Preinstalled SIMATIC software and customized software
packages
- additional functions due to PCIe slot
- Frontplate design in color and labeling of the interfaces
- Large number of interface options in the configurator in a
very small space

6/10

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Customized Automation
OEM products
Flexible front design concept for HMI products

■ Overview

■ Benefits
The flexible front-mounting concept allows customized HMI
solutions based on the field-proven SIMATIC components.
A project using the flexible front-mounting concept is the
obvious choice especially for the following customer requirements:
• Customized integration of operator elements and display
systems
• High integration density of SIMATIC products
• Demand for customized design and layout
• Demand for optimal integration into plants and machinery
• Compact design as stand-alone product in enclosure
• Compact design as built-in unit at the machine level
• Use of field-proven components and thus also optimized timeto-market
These requirements can be implemented for the customer by
means of a flexible front-mounting concept.

MP 377 15" Touch OEM according to flexible front-mounting
concept for injection molding machines
Customer requirements with regard to HMI devices are
extremely diverse. The flexible front-mounting concept makes it
possible to meet these diverse customer-specific requirements.
The flexible front-mounting concept enables customized front
design as well as customized layout of the operator elements.
The SIMATIC products form the technical basis of a device
developed according to the flexible front-mounting concept.
The diversity of the standard products enables integration from
the small 6" Flat Panel right up to high-performance PC
technology. The customer's own, typical operator philosophy
can also be optimally implemented since the flexible frontmounting concept offers the wide range of operator elements –
from the classic 3SB operator elements, through short-stroke
keys, right up to membrane keyboards.

The general conditions for a project using the flexible frontmounting concept are:
• Minimum unit quantity 100 p.a.
• Project agreement
- With unit quantity start-up forecasting and annual unit
quantities for the project
- for funding development costs
- Key project dates and standard start-of-delivery dates
- Logistics with delivery times

■ Application
The industrial environment imposes diverse requirements on
technology and design. Thanks to its variable and modular
approach, the flexible front-mounting concept opens up diverse
options for re-combining SIMATIC standard components in a
compact device configuration with individualized design and
layout. The possible uses are thus diverse and universal.

The flexible communication options with PROFIBUS or
PROFINET facilitate integration into new or existing machine
concepts. Fail-safe operation can be implemented by using
PROFIsafe components. To meet individual customer requirements, a device built in accordance with the flexible frontmounting concept can be designed as a built-in device or as a
stand-alone unit. If designed as a stand-alone unit, care is taken
to make the enclosure slimline and modern in appearance.

6

Siemens ST 80 / ST PC · 2013

6/11

© Siemens AG 2013

Customized Automation
OEM products
Flexible front design concept for HMI products

■ Design

■ More information

The flexible design and the use of standard SIMATIC products
make it possible to meet just about every technical requirement
with regard to customized HMI. Components that can be
combined to form an individualized HMI are listed below:

Quotation preparation

Basic devices:
• Flat Panels with different screen diagonals
• Thin Client
• Comfort Panel
• Panel PC

Determining:
• One-time project costs
• Costs for sample devices/prototypes
• Standard unit prices
• General conditions (product agreement)

Operator control:
• Touch functionality
• Keys functionality with
- 3SB elements
- Short-stroke keys
- Membrane keys (also illuminated)
• Keyswitches etc.

There must be a minimum limit to the annual unit quantity/
purchase quantity (minimum quantity per version: from 100) and
this must be agreed with the project customer. Customized
products can only be ordered in conjunction with a product
agreement. A customer-specific order number is allocated
during the product agreement process.

Additional elements:
• High-speed keys via PROFINET
• Emergency stop (also PROFIsafe)
• Front USB etc.
Design:
• Stand-alone (IP65 at front, <= IP54 at rear)
• Built-in unit (IP65 at front; IP20 at rear)
• Slimline enclosure design
Device connection:
• With support arm via VESA 100 on rear of enclosure
• Connected at the edges using hinges
• Installation in machinery
Design:
• Customized design
• Customized key layout
• Customized symbols and logos

Product specification in accordance with customer
requirements. Quotation drafted by SIMATIC HMI specialists.

Contacts
Please contact the HMI representatives of your Siemens sales
office/national company.
Additional information in the Internet is available at:
http://www.siemens.com/hmi-oem
Flexible front-mounting concept project development and
service
Customized projects using the flexible front-mounting concept
are developed and produced in different steps in accordance
with quality standards. Prototypes are created to test products.
Once the devices have been approved by the customer, they
undergo certification and are introduced into the production
process.
Devices are produced in standard product factories, ensuring
observation of customer quantity forecasts. For this purpose,
individual quantity forecasts are exchanged with the customer.
In the event of questions and problems, customers can contact
our worldwide 24-hour SIMATIC Customer Support.
Customized products can only be ordered in conjunction with a
product agreement.
The following points are defined in the product agreement:
• Delivery and pricing
• Logistics - annual volume, purchase quantity, delivery batch
volumes
• Spare parts
• Service
• Repairs/spare parts storage

6

The repair concept is also agreed with the customer. The
necessary customized spare parts (device fronts) are defined
here and offered to customers for their products after completion
of delivery.

6/12

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Customized Automation
OEM products
MP 277 8" Touch control console

■ Overview
OEM MP 277 8.4" Touch

■ Technical specifications
•
•
•
•
•
•

Rugged die-cast aluminum housing
8.4'' TFT display
800 x 600 pixel resolution
Operation by means of touch screen and optional joystick
Customized application and customized WinCE image
Degree of protection on front: IP65.

Option
• Different housing color

■ Ordering data
OEM MP 277 8.4" Touch

■ Benefits
•
•
•
•
•
•
•

Heavy-duty, die-cast aluminum housing
Easy mounting on patient table with clamping device
Low space requirements
Extremely good readability
Simple operation
Joystick can be connected optionally on left or right
Ethernet communication

Order No.
On request

Customized products can only be ordered in conjunction with a
product agreement. The following points are defined in the
product agreement:
• Status: Released for delivery
• Project runtime: None
• Non-recurring costs: None
• Minimum quantity: 200

■ More information
Additional information is available in the Internet under:
http://www.siemens.com/hmi-oem

■ Application
The OEM MP 277 8.4" Touch is suitable for use as a control
console for coronary angiography systems in the medical field.

6

Siemens ST 80 / ST PC · 2013

6/13

© Siemens AG 2013

Customized Automation
OEM products
SIMATIC HMI Net Panel

■ Overview

■ Benefits

Professional display system for continuous,
maintenance-free operation
The SIMATIC HMI Net Panel is multifunctional when it comes to
rugged, large-scale display applications for industrial areas, as
it is ideal for production plants and control stations or for trade
fairs and information points visited by the public.
The Net Panel is based on a reliable industrial PC of the
SIMATIC IPC series and is designed for 24-hour, maintenancefree operation in an industrial environment. It is extremely flexible
in operation and can be used as a stand-alone solution or in the
network as a complete industrial display system comprising
several Net Panels. For applications that require audio output,
variants of the Net Panel are available with audio modules and
speaker equipment.
Remote Control for setting up the SIMATIC HMI Net Panel
The Remote Control Software included in the scope of delivery
allows the Net Panel to be operated either locally or via the
network. It enables the brightness and volume to be adjusted
and the backlight to be switched off.

6

For self-diagnosis the device temperature can be indicated.
The Remote Control software allows the function to be shut down
to prevent burn-in effects (anti-image sticking). The anti-image
sticking function should, however, only be deactivated when
adequate measures have been implemented on the Net Panel to
prevent image sticking.
Remote Operate as client/server solution for industrial
display systems (optional)
When Remote Operate is installed, four virtual graphics cards
can be set up on one IPC and presented as extended desktops.
On every SIMATIC HMI Net Panel, a Remote Operate client is
installed that is assigned to a virtual graphics card. The different
screen contents are distributed to the virtual graphics adapters
using the HMI software WinCC. If the Net Panel is equipped with
sound, MP3 and Wave files can be sent to a specific Net Panel
where they can be played, using an easily accessible function.

6/14

Siemens ST 80 / ST PC · 2013

• High degree of system availability due to maintenance-free
industrial design with IP65 degree of protection for continuous
24-hour operation
• High security of investment due to rugged industrial products
from SIMATIC that will remain available over the long term
• Reduced costs through low-wear and power-saving LED
backlight and anti image sticking function
• Easy, cost-efficient integration in a standard network
environment without VGA/DVI/HDMI extensions or expensive
video signal extenders
• Optionally available with audio module and loudspeaker for
sound output
• Flexible mounting on support arm systems, wall and ceiling,
as well as back-to-back mounting and with an angle of inclination of up to 20° from the vertical
• Remote Control Software (locally on the device and remotely
from the network) for the easy parameterization of
- Brightness
- Deactivation of backlighting
- Status messages of display
- Speaker control
• Supported by WinCC flexible 2008 SP2 or higher
(IPC427C with 1920 x 1080 resolution)

■ Application
The SIMATIC HMI Net Panel is designed for demanding largescale displays in the industrial environment.
It is based on rugged, reliable PC technology with interfaces for
easy, cost-efficient integration in existing networks and offers
maximum flexibility for positioning and mounting.
The large LCD display with LED backlight, round-the-clock
operation, and full PC openness make the large-scale display
ideal for use as an industrial manufacturing display, add-on
system, multimedia display, process visualization system,
railway station and airport display (check-in, gate, baggage
claim, advertising display) or at trade fairs, in shopping centers,
hotels, museums and more.

■ Design
The SIMATIC HMI Net Panel is a rugged display system with an
integrated industrial PC and optional audio and loudspeaker
equipment.
• LCD display with 1920 x 1080 pixel full HD resolution
• Power saving and long-life LED backlight
• Integral SIMATIC industrial PC
• Rugged and attractive device design with reduced enclosure
depth
• Degree of protection IP65 all-round, industry compatible
• Solid, shatterproof front pane of 6 mm laminated glass
• Anti-glare front pane resistant to welding beads
• Safety eyebolts (removable as required) for additional
protection against dropping in suspended installations
• Optional: adapter for Rose & Krieger FSK 50 support arm
system
• Integrated wide-range power supply
• Rear connector for 1x USB (with IP65 protective cap),
1x Industrial Ethernet (M12 4-pin with protective cap)
• Rear Quick-On connection for integrated 100 - 240 V power
supply (connector included in scope of delivery)
• Rear status indicator

© Siemens AG 2013

Customized Automation
OEM products
SIMATIC HMI Net Panel

■ Technical specifications
SIMATIC HMI Net Panel

SIMATIC HMI Net Panel

Size

46" (116 cm) LCD TFT

46" (116 cm) LCD TFT

Resolution

1920 x 1080 Full HD (16:9)

1920 x 1080 Full HD (16:9)

Colors

16.7 million colors

16.7 million colors

Reading angle

+/- 178°

+/- 178°

Backlighting

LED backlight

LED backlight

Brightness

Typically 400 cd/m²

Typically 400 cd/m²

Processor

Celeron M 1.2 GHz

Core2 Solo 1.2 GHz

Main memory

1 GB

4 GB

Mass storage

Compact Flash 4 GB

250 GB hard disk

Operating system

Windows Embedded Standard 2009

Windows Embedded Standard 2009

Enclosure design

Industry-compatible steel enclosure, black,
powder-coated

Industry-compatible steel enclosure, black,
powder-coated

Glass front

Shatterproof front pane of 6 mm laminated glass,
anti-glare, resistant to welding beads

Shatterproof front pane of 6 mm laminated glass,
anti-glare, resistant to welding beads

Audio module

2x 15 W audio module

2x 15 W audio module

Loudspeakers

1 pair, mounted to left and right, BOSE or alternatively
Visaton

1 pair, mounted to left and right, BOSE or alternatively
Visaton

USB 2.0

1x at rear (with IP65 protective cap)

1x at rear (with IP65 protective cap)

Ethernet

1x Industrial Ethernet, D-coded
(M12 4-pin with protective cap)

1x Industrial Ethernet, D-coded
(M12 4-pin with protective cap)

Power supply

100 - 230 V AC Quick-On plug connector

100 - 230 V AC Quick-On plug connector

Keyboard; mouse

Connectable via USB interface
(optional USB hub recommended for commissioning)

Connectable via USB interface
(optional USB hub recommended for commissioning)

Degree of protection

IP 65 all-round; IP54 when USB is plugged in

IP 65 all-round; IP54 when USB is plugged in

Vibration load during operation

1g outline specification

1g outline specification

Shock loading during operation

5g outline specification

5g outline specification

Ambient temperature during operation

5…45°C for 24 h operation

5…45°C for 24 h operation

CE

CE

External dimensions
(W x H x D in mm), weight

1138 x 681 x 130; approx. 55 kg

1138 x 681 x 130; approx. 55 kg

External dimensions (W x H x D in mm)
with BOSE loudspeaker, weight

1410 x 681 x 130; approx. 58 kg

1410 x 681 x 130; approx. 58 kg

External dimensions (W x H x D in mm)
with Visaton loudspeakers, weight

1565 x 681 x 130; approx. 57 kg

1565 x 681 x 130; approx. 57 kg

HMI software

Supported by WinCC flexible 2008 SP2 or higher

Supported by WinCC flexible 2008 SP2 or higher

Remote Control Software

For adjustment and control, locally or via network

For adjustment and control, locally or via network

Continuous glass front with narrow protective frame

Continuous glass front with narrow protective frame

Auto-refresh function for anti image sticking

Auto-refresh function for anti image sticking

2-point mounting, M8 on left and right sides of enclosure,
75 mm spacing

2-point mounting, M8 on left and right sides of enclosure,
75 mm spacing

2x removable safety eyebolts on top of enclosure

2x removable safety eyebolts on top of enclosure

Display

PC configuration

General features

Audio (optional)

Interfaces

Ambient conditions

Conformity
Approvals

6

Dimensions

Software

Special features

Siemens ST 80 / ST PC · 2013

6/15

© Siemens AG 2013

Customized Automation
OEM products
SIMATIC HMI Net Panel

■ Ordering data
SIMATIC HMI Net Panel
Intelligent large-scale display;
1920 x 1080 full HD widescreen;
1 x Industrial Ethernet interface and
1 x USB on the rear; Windows
Embedded Standard 2009; remote
control software; enclosure design
according to IP65, if plugged in at
the rear IP54; includes Quick-On
connector for 100 - 230 V power
supply; CE
• Preferred type:
46" screen diagonal,
IPC Celeron M 1.2 GHz,
1 GB RAM, 4 GB CF Card,
without speakers,
without audio module
• 46" screen diagonal,
IPC Celeron M 1.2 GHz,
1 GB RAM, 4 GB CF Card,
with Visaton speaker,
with audio module 2 x 15 W
• 46" screen diagonal,
IPC Celeron M 1.2 GHz,
1 GB RAM, 4 GB CF Card,
with BOSE speaker,
with audio module 2 x 15 W
• 46" screen diagonal,
IPC Core2 Solo 1.2 GHz,
4 GB RAM, 250 GB hard disk,
without speakers, without audio
module
• Preferred type:
46" screen diagonal,
IPC Core2 Solo 1.2 GHz,
4 GB RAM, 250 GB hard disk,
with Visaton speakers,
with audio module 2 x 15 W
• Preferred type:
46" screen diagonal,
IPC Core2 Solo 1.2 GHz,
4 GB RAM, 250 GB hard disk,
with BOSE speakers,
with audio module 2 x 15 W

Order No.

Support arm systems
Various support arm systems
for ceiling, back-to-back,
wall or stand mounting
are offered by Rose & Krieger.

6AV7426-0AA12-0BA0

6AV7426-0AA12-1BA0

6AV7426-0AA12-2BA0

6AV7426-0AD35-0BA0

6AV7426-0AD35-1BA0

6AV7426-0AD35-2BA0

■ More information
Customized modification options on request. Recommended
support arm system from Rose & Krieger.

6

SIMATIC HMI specialists define the product modifications
precisely in accordance with customer requirements.
This is followed by drafting of a quote with:
• Non-recurring costs
• Prototype costs
• Standard unit prices
• and the marginal conditions in the form of a product
agreement (e.g. minimum quantity).
The defined device can then be ordered easily using this
product agreement and a customized order number.

6/16

Order No.
Accessories

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Customized Automation
Turnkey products
Turnkey products

■ Overview
Turnkey products are ready-to-install and ready-to-use
SIMATIC HMI products.
The benefits are found in the optimal mechanical installation of
the devices, ergonomic, functional and with tested heat balance,
and flexible in installation.
Products
• HMI operator stations
HMI devices with display diagonal of 10" and more are installed
in selected enclosures to suit the function. HMI operator stations
can be used wherever it is not possible to install human machine
interface devices in a control cabinet or direct at the machine,
and where off-the-shelf, turnkey products can save on
engineering overhead. Installation of a customized image in the
devices is possible (ready-to-run). Customized SIMATIC turnkey
products offer standardized quality from a single source.
• Backplane cover
The backplane cover enables the enclosure of flat HMI products
such as the HMI IPC 477C or MP 377. The backplane cover is
provided with a VESA flange on the rear. More operator elements
can be installed on the side in additional enclosures.

6

Siemens ST 80 / ST PC · 2013

6/17

© Siemens AG 2013

Customized Automation
Turnkey products
HMI operator stations for turnkey products

■ Overview

■ Application

Turnkey products are SIMATIC HMI products or "ready-to-run"
operator stations, i.e. pre-configured, ready for installation and
ready-to-run SIMATIC Panels Thin Client, Multi Panels or Flat
Panels and Panel PCs, installed in customer-specific enclosures.
Examples are Multi Panels fitted in customized die-cast
aluminum enclosures with external keyboard; with installed
application software, ready for connection, and ready-to-run.

Complete HMI operator stations can be used wherever
HMI devices cannot be installed in a control cabinet or directly
at the machine. Operator stations are suitable for:
• Industrial application
• Near-industrial application
• Use in secondary applications in food, beverage and tobacco
production
• Stainless steel version in the primary areas of the food,
beverages and tobacco industries
HMI turnkey products can be used wherever prefabricated,
ready-to-run hardware and software products can be used to
save on engineering.

■ Design

Application example: Multi Panel in aluminum enclosure with operator
controls, two-tier and with external keyboard

■ Benefits
High industrial capability thanks to an all-round rugged, tried
and tested design:
• Ergonomic, technically proven and certified solutions ready
for operation
• Safe operation even under difficult environmental conditions
• Temperature-tested and temperature-monitored
• Suitable even for special industries, e.g., stainless steel
versions for the food, beverages and tobacco industries
• For high availability and a safe return on your investment
• Siemens quality support, service and repair

6

The following issues are considered when developing the
HMI operator stations:
• Optimal HMI product installation technology to eliminate
thermal hotspots and heat pockets in the housing
• Calculation of actual maximum permissible ambient temperature of the entire operator station in continuous duty at
location of use Data takes into account device heat dissipation
values
• Ensuring the adherence to the load limits for rotary mass
storage systems and large displays verified by shock and
vibration tests on the entire operator station during operation
• Adherence to legal regulations (certifications)
• Determination and testing of required degrees of protection
and EMC measures
• Assurance of surface quality along with its abrasion and
chemical resistance
• To the greatest possible extent, passive technology provides
the basis for all measures to improve the suitability of use of
the operator stations in specific environments (e.g., no active
air conditioning). The aim is to ensure durability and fault-free
operation with minimum maintenance.

6/18

Siemens ST 80 / ST PC · 2013

The HMI operator station concept is based on a modular system
where HMI devices are built into selected enclosures to suit the
functionality.
• HMI device enclosure for all-round protection (IP65)
• Mounting possible on stand or supporting bracket
• Rotation possible by means of adjusting elements
• Connection option for external keyboard and mouse
• Installation option for specific hardware components
Ambient temperature for turnkey products
The ambient temperature is always lower than the max. permissible ambient temperature of the HMI products (temperature
values in Manual) installed in the operator station housing.
Depending on the components and version (e.g. according to
heat dissipation), permissible ambient temperatures around the
operator station will vary between 5°C and 40 °C.
Higher operator station ambient temperatures can be achieved
by applying additional cooling measures.

■ Function
•
•
•
•
•
•
•
•
•

Fatigue-free, fast operation
Operator station can be quickly adapted to different operators
Coherent, easy-to-learn operator philosophy
Rugged against shocks and vibrations in operation
Suitable device selection
(SIMATIC HMI devices from 10“ display)
Ensuring the data transfer and access to drives and interfaces
Direct operation of the machine (conventional operator
elements for direct connection to machine units)
Simple alphanumeric input
Cleaning agents taken into account

© Siemens AG 2013

Customized Automation
Turnkey products
HMI operator stations for turnkey products

■ Ordering data

■ More information

Ordering notes

Contacts

Product specifications and quotation preparations
• Product specification according to customer requirements
• Quotation preparation by SIMATIC HMI specialists,
specification of:
- one-time project costs
- costs for sample devices/prototypes
- standard unit prices
- general conditions (product agreement)

Please contact the HMI representatives of your Siemens sales
office/national company.
http://www.siemens.com/hmi-oem

Processing
Customized turnkey products are developed and produced in
various stages in accordance with quality standards. Prototypes
are created to test products. Once the devices have been
approved by the customer, they undergo certification and are
introduced into the production process.
Devices are produced using standard plant facilities, ensuring
observation of customer quantity forecasts. For this purpose,
individual quantity forecasts are exchanged with the customer.
In the event of questions and problems, customers can contact
our worldwide 24-hour SIMATIC Customer Support. This is
complemented by a special OEM After Sales Support service.
Customer-specific project hotlines can be set up for bulk
quantity customers.
Customized products can only be ordered in conjunction with a
product agreement. The following points are defined in the
product agreement:
• Delivery and pricing
• Logistics - annual volume, purchase quantity, delivery batch
volumes
• Spare parts
• Service
Repairs/spare parts storage
Only identified repairs are performed. The required customerspecific spare parts (device fronts) are to be stored and
provided by the customer upon delivery completion.

6

Siemens ST 80 / ST PC · 2013

6/19

© Siemens AG 2013

Customized Automation
Customized software
Customized software

■ Overview
Customized software

Remote Operate Software

In the case of customer-specific products, the software can also
be individually installed. This includes the generation of
operating systems and also the integration and installation of
driver software and images – for complete, turnkey systems.

The HMI Remote Operate Software is an industrial remote
control system based on Ethernet.

The customized software suite comprises:
• Generation of operating systems
- for Windows XP embedded, for example
- and the RMOS3 real-time operating system from Siemens
- for customized LINUX installation
• Integration and installation of driver software and pre-installed
images
- for additional cards, controllers, or memory media, for
example
- for completely turnkey systems
In addition, customized software products based on our
experience in the industrial automation offer an opportunity to
set up multi-user systems and industrial remote operation and
the possibility of integrating SIMATIC S7 into building
automation:

6

6/20

Siemens ST 80 / ST PC · 2013

The software (server) enables the creation of a multi-user system
with HMI IPC. Up to 6 operator stations (slaves) based on clients
with MP 377 and HMI IPCs. The clients can also be assigned to
several servers.
KNX/EIB2S7
Bus systems for building management systems, such as
KNX/EIB, and a host of associated components, are used for
automation of building systems.
While controllers for the room level are used for local automation,
field-proven industrial components like SIMATIC are resorted to
in the case of more complex, higher-level automation.
Communication between the automation levels takes place over
Ethernet using special KNXnet/IP interfaces. The KNX/EIB2S7
software package provides blocks for communication between
SIMATIC S7 and building automation components. This means
message frames of the KNX bus can be processed in a SIMATIC
controller.

© Siemens AG 2013

Customized Automation
Customized software
Remote Operate Software

■ Application
Remote Operate Software
Remote Operate Clients
PD[&OLHQWVSHU6HUYHU
3DQHO3&
5HPRWH2SHUDWH

035HPRWH2SHUDWH

5HPRWH2SHUDWH
3&

*B67B;;B

,QGXVWULDO(WKHUQHW

5HPRWH2SHUDWH
3&

Remote Operate Server

Panel PC with connected thin clients

Multi-user system with Panel PCs for up to 6 operator stations
based on Thin Clients with MP 377 and PC 477
• Including operator lock
• In one software application with identical image contents
• Identical screen resolution
• Excluding server operating system
• Industrial remote control
- Independent of the installed software
• Identical images on all devices
• Automatic scaling takes place in the case of differences in
screen resolution between server and client

• Resolution up to 1280 x 1024 with true color
• Remote Operate Server with Windows XP Professional,
Windows XP embedded, or Windows 7
• Up to 6 clients on one server
• Communication via Ethernet
• Designed for industrial requirements
- Automatic login
- Simple administration
- Automatic reconnect
- Permanent server/client assignment
- Administration of operator authorization
- Can be used after Windows login
- Optional key-operated switch for operator authorization

Siemens ST 80 / ST PC · 2013

6/21

6

© Siemens AG 2013

Customized Automation
Customized software
SIMATIC KNX/EIB2S7

■ Overview

■ Design

• Software for communication between SIMATIC S7 and
components of a building automation system
• For using components from industrial automation in the area
of building automation
• Enables the integration of actuators/sensors into a
KNX/EIB bus in automation solutions with SIMATIC S7
• For transferring information from the building automation
system for automating a production plant

■ Benefits
• Use of field-proven industrial components in the area of
building automation
• Use of information from building automation for automating
production plants
• Simple transfer of configuring data from the KNX configuring
tool ETS3
• Automatic matching of KNX addresses with the associated
SIMATIC addresses
• Use of the SIMATIC standard

■ Application
With rising energy awareness and increased requirements
regarding user-friendliness and security, recent years have seen
building automation facing far-reaching demands.
Bus systems for building management systems, such as
KNX/EIB, and a host of available components for these are used
for implementing the corresponding systems.
While controllers for the room level are used for local automation,
field-proven industrial components like SIMATIC are resorted to
in the case of more complex, higher-level automation.
Communication between the automation levels takes place over
Ethernet using special KNXnet/IP interfaces.
The KNX/EIB2S7 software package provides blocks for communication between SIMATIC S7 and building automation components. This means message frames of the KNX bus can be
processed in a SIMATIC controller.

6

The SIMATIC S7 is connected with the KNX/EIB components via
KNXnet/IP interfaces. The interfaces connect the KNX/EIB bus
with the Industrial Ethernet bus of the SIMATIC S7.
Up to 5 KNXnet/IP interfaces can be connected to a SIMATIC S7
controller Up to 7,000 group addresses can be monitored,
operated and read via these interfaces. The maximum number
of group addresses depends on the controller type and the
number of connected KNXnet/IP interfaces.
KNX/EIB2S7 supports the following CPUs of the SIMATIC S7:
• ET 200
- IM 151-8 PN/DP CPU
• S7 300/400
- CPU 315-2 PN/DP
- CPU 317-2 PN/DP
- CPU 319-3 PN/DP
- CPU 414-3 PN/DP
- CPU 416-3 PN/DP
• Soft PLC
- SIMATIC WinAC RTX 2008 SP 1
• SIMATIC S7-300 with CP 343-1
- CPU 315-2 DP
- CPU 317-2 DP
- CPU 319-3 PN/DP
• SIMATIC S7-400 with CP 443–1 Advanced
- CPU 412-2 MPI/DP
- CPU 414-2 MPI/DP
- CPU 416-2 MPI
• Supported KNXnet/IP interfaces:
- N 146/2 IP router
- N 148/221 IP interface
- N 350E IP controller
- N 151 IP viewer

■ Mode of operation
The KNX components are parameterized with the ETS 3 software
of the Konnex organization.
The KNX/EIB2S7 Editor is based on the exported parameterization data of ETS3 and evaluates the group address, data type,
name and description. It only remains to select the group
addresses that are to be received and to mark those that are to
be automatically read at initialization.
Addresses are assigned automatically by the editor. The
addresses can be viewed in the Editor or exported for documentation.
The parameterization of the blocks necessary for the SIMATIC
is generated by the Editor at the click of a mouse and can
then be downloaded to the SIMATIC. The blocks contained in
KNX/EIB2S7 handle the communication on the basis of this
parameterization.
When data is received, the current values are saved in the data
blocks provided for them. The values that have been updated
are then marked. Equally, there are blocks available for the
selective reading and writing of values.

6/22

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Customized Automation
Customized software
SIMATIC KNX/EIB2S7

■ Technical specifications
Representation of the data types
Data type

KNX value

EIS type

SIMATIC
data type

Representation in the SIMATIC

User conversion

DPT1

BOOL

EIS1

Bit

TRUE/FALSE

n

DPT2

1 bit controlled

EIS8

Byte

MSB ([0000 00XY) LSB

n

X = controlled
Y = Value
DPT3

4 bits

EIS2

Byte

MSB (0000 XYYY) LSB

n

X = Increase/decrease
Y = Step 0-7
DPT4

Char

EIS13

Char

DPT5

1 byte unsigned

EIS14

Byte

n

DPT6

1 byte signed

EIS14

Byte

y

DPT7

2 bytes unsigned

EIS10

Word

DPT8

2 bytes signed

EIS10

Int

Representation in 2s
complement

n

DPT9

2 bytes float

EIS5

Real

Conversion implicit in the driver

n

DPT10

Time of Day

EIS3

DWord

MSB (0000 0000/dddh
hhhh/00mm mmmm/00ss ssss) LSB

n

ASCII

n

n

d = day 0 no day; 1-7
h = hour 0-23
m = minute 0-59
s = second 0-59
Important! No value check by the
driver
DPT11

Date

EIS4

DWord

MSB (0000 0000/000d dddd/0000
mmmm/0yyy yyyy) LSB

n

d = day 0-31
m = month 0-12
y = year 0-99
(0-89 = 2000-2089; 90-99
= 1990-1999)
Important! No value check by the
driver
DPT12

4 bytes unsigned

EIS11

DWord

DPT13

4 bytes signed

EIS11

D Int

Representation in 2s
complement

n

DPT14

Float

EIS9

Real

IEEE754

n

DPT15

Access

EIS12

DWord

MSB (XXXX6 XXXX5/XXXX4 XXXX3/
XXXX2 XXXX1/EPDC NNNN) LSB

n

n

6

X = AccessCode 6-digit; 0-9;
1 nibble each
E = 1 detection error
(reading of access information code
was not successful)
P = Permission 0=not accepted;
1= accepted
D = Direction 0=left to
DPT16

String

■ Ordering data
KNX/EIB2S7 program package

EIS15

String (14)

Driver evaluates header of the S7
string and then generates the
14-character long EIB string.

n

Order No.
6AV6643-7AC10-0AA1

Task:
Software for connecting KNX/EIB
components from building management systems to SIMATIC S7
Type of delivery:
Editor, function blocks for
SIMATIC S7, samples,
documentation on CD
License for Editor on USB flash drive

Siemens ST 80 / ST PC · 2013

6/23

© Siemens AG 2013

Customized Automation
Customized software
S7 OpenModbusTCP

■ Overview

■ Design
Communication with Modbus TCP stations is performed via a
communications processor (CP) or via the integrated PN
interface of the SIMATIC S7 CPU.

SIMATIC S7-400
with CP443-1

SIMATIC S7-400
with 2x CP443-1

SIMATIC ET 200S

tvki|zG
{jw
MODBUS
participant

p•‹œš›™ˆ“G
l›Œ™•Œ›
MODBUS
participant

MODBUS
participant

G_ST80_XX_00520

SIMATIC S7-300

• Software for communication between SIMATIC S7 and
devices that support the Modbus TCP protocol
• Expansion or upgrade of existing plants with SIMATIC
automation systems
• Connection of controllers and systems from different
manufacturers

■ Benefits
• Easy coupling of systems from different manufacturers
with SIMATIC automation systems over Industrial Ethernet
• No specialized Modbus know-how required
• Engineering with the standard tool SIMATIC STEP 7
• Fast configuration with the help of a wizard
(only available for specific versions)

■ Application

6

MODBUS is a protocol that is widely used internationally, open
to all users and supported by many manufacturers. MODBUS/
TCP was developed from it for use in modern networks. This
protocol is now an open Internet draft standard that was introduced by IEFT (Internet Engineering Task Force), the organization for Internet standardization. This openness means that
every manufacturer and user is able to use this protocol –
a possibility that many leading manufacturers have already
availed of. The increasing expansion of Ethernet communication
into industrial areas as well as the office environment has
extended the use of MODBUS/TCP in every sector. Heterogeneous system landscapes are the typical areas of use.

6/24

Siemens ST 80 / ST PC · 2013

A SIMATIC S7 controller can communicate simultaneously with
more than one Modbus TCP station simultaneously, depending
on the number of connection resources of the S7 CPU.
S7 OpenModbusTCP CP and Redundant V2 support the
following CPs of SIMATIC S7:
• S7 300
- CP 343-1
• S7 400
- CP 443-1
S7 OpenModbusTCP PN CPU supports the following CPUs of
SIMATIC S7:
• ET 200
- IM 151-8 PN/DP CPU
• S7 300/400
- CPU 314C-2 PN/DP
- CPU 315-2 PN/DP
- CPU 317-2 PN/DP
- CPU 319-3 PN/DP
- CPU 412-2 PN
- CPU 414-3 PN/DP
- CPU 416-3 PN/DP
• Soft PLC
- SIMATIC WinAC RTX

■ Mode of operation
The Modbus block functions according to the client/server
principle. The client is the active station and the server is the
passive station in the communication process. Data is
exchanged between the communication partners by means of
various different function codes. The S7 can be operated as a
client as well as a server during transmission.
In the initialization phase, it is determined on which S7 data
blocks the Modbus registers and coils should be represented.
A distinction is made between client and server functionality
during cyclic operation:
• If the S7 is operating as a client, when a task is activated, a
Modbus message frame is generated from the specified
current parameters and sent to the coupling partner over the
TCP/IP connection. After the response frame has been
received and the data has been checked and found to be
consistent, the required actions, such as reading or writing
data, will be performed. Any errors that occur during evaluation or processing will be indicated on the Modbus block.
• If the S7 is operating as a server, the block waits for a
response frame from the client. If a frame is received from a
client, it is checked and evaluated. After the frame has been
checked and found to be consistent, the response frame is
generated and the required actions, such as reading or writing
data, will be performed. A processed request, or any errors
that occur during evaluation, will be indicated on the Modbus
block.

© Siemens AG 2013

Customized Automation
Customized software
S7 OpenModbusTCP

■ Technical specifications
2XV9 450-1MB00

2XV9 450-1MB02

2XV9 450-1MB11

Client/server functionality

•/•

•/•

•/•

Function codes

1, 2, 3, 4, 5, 6, 15 and 16

1, 2, 3, 4, 5, 6, 15 and 16

1, 2, 3, 4, 5, 6, 15 and 16

Modbus address range

0 - 65535

0 - 65535

0 - 65535

Read register

125

125

125

Write register

123

123

123

Read bits

2000

2000

2000

Write bits

1968

1968

1968

Capable of multi-instance

•

•

•

Max. number
of parallel block calls

• CPU-dependent
• Client: No limits on block calls; max.
number of blocks simultaneously
active is limited by the CPU
(AG_SEND)
• Server: Limited by the max. number
of AG_RECV calls of the CPU

• Unlimited number of block calls;
• Number of simultaneously established connections is dependent on
the CPU

• CPU-dependent
• Client: No limits on block calls; max.
number of blocks simultaneously
active is limited by the CPU
(AG_SEND)
• Server: Limited by the max. number
of AG_RECV calls of the CPU

Connection
configuration

Static connections over NetPro

Dynamic connections over TCON and
TDISCON

Static connections over NetPro

Communication

AG_(L)SEND/
AG_(L)RECV

TSEND/
TRCV

AG_(L)SEND/
AG_(L)RECV

Work memory requirement
FB (Client/Server)

16 KB

19 KB

20 KB

approx. 1 KB

approx. 1 KB

approx. 1 KB

Can be used in CFC/PCS 7

•

•

•

Used with older CPs that do not
support AG_CNTRL

Yes

-

No

Multiplexing of TCP connections

CP-dependent

-

CP-dependent

Redundancy functions

-

-

Single-sided or two-sided redundancy is possible

Bit memories/timers can be used

No

No

No

Data volume

IDB

■ Ordering data
S7-OpenModbusTCP CP

Order No.
2XV9450-1MB00

Task:
Software for coupling ModbusTCP
devices to SIMATIC S7 via a communications processor (CP)

2XV9450-1MB11

Task:
Software for coupling ModbusTCP
devices to SIMATIC S7 H stations
via 2 communications processors
(CPs)

Type of delivery:
Function blocks for SIMATIC S7,
example projects, documentation
on CD
S7-OpenModbusTCP PN CPU

Order No.
S7-OpenModbusTCP RED

2XV9450-1MB02

6

Type of delivery:
Function blocks for SIMATIC S7,
example projects, documentation
on CD

Task:
Software for coupling ModbusTCP
devices to SIMATIC S7 via the integrated PN interface
Type of delivery:
Function blocks for SIMATIC S7,
example projects, documentation
on CD

Siemens ST 80 / ST PC · 2013

6/25

© Siemens AG 2013

Customized Automation
Examples of sector products
Examples of sector products

■ Overview

SIMATIC HMI products are provided with additional features in
order to facilitate optimum use in specific sectors of industry.
Stainless steel front panels for the food, beverages and tobacco
industry are one such example. With the exception of their front
panels, the devices are identical to standard products in respect
of function and technology.
We can offer products for the following sectors:
• Renewable energy
• Automotive industry - HMI for factory automation
• General machine construction
• Food and beverages industry, pharmaceuticals
• Oil & gas, chemicals industry and shipbuilding
Customized products for various industries are developed and
produced in association with a customized product agreement.

6

6/26

Siemens ST 80 / ST PC · 2013

Examples:
• Application area renewable energy:
- SIMATIC Rack PC with flexible expansion
- SIMATIC Box PC: 627/427 with QNX
• Use in the automobile industry:
- HMI operator stations
- Front panel for Panel PC, 15" with arrow keys on the side
- Mobile Panel 277 10" Remote Operate
• Application area mechanical equipment manufacture,
general:
- Touch and Key front panel 15" for Panel PC, resistant to
honing oil
- Flat Panels 10.4" for Panel PCs – Flat Panel SCD1900 portrait
• Area of application food and beverages industry and
pharmaceuticals:
- Panels and Panel PCs with stainless steel front
- HMI panels as rear-mounting devices
- Flat Panels with stainless steel front
- HMI stainless steel operator stations
• Area of application oil & gas, chemicals and shipbuilding:
- MP 377 15" Touch daylight readable

© Siemens AG 2013

Customized Automation
Renewable energy
Renewable energy

■ Overview
SIMATIC HMI products are provided with additional features in
order to facilitate use in specific sectors.
Photovoltaic systems are subject to hardly any mechanical
stress and therefore require little maintenance. This also requires
reliable and low-maintenance devices in the automation system.
With the wide operating temperature range at a high computing
power, with their various mounting styles, as well as options for
diagnostics and data backup, SIMATIC Panels and IPCs meet
these requirements.

Wind farms can be used in all climatic zones and also in poorly
accessible areas, e.g. offshore. The requirements regarding the
control systems are accordingly diverse, and complete freedom
from maintenance of the devices is required. The industrial PCs
of the 427 series can meet these requirements. Versions of the
Microbox treated by special paint processes can also be used
in salt-laden air.

6

Siemens ST 80 / ST PC · 2013

6/27

© Siemens AG 2013

Customized Automation
Renewable energy
Solar systems

■ Overview

■ Application

Solar systems
Compared to other power plants, photovoltaic systems are
subject to hardly any mechanical stress and therefore require
little maintenance. The same also applies for solar and solarthermal systems. This also reduces the maintenance overhead
on the devices. The SIMATIC Industrial PCs and Panels meet
these requirements through the targeted selection of highquality components and special production processes.

■ Benefits

6
SIMATIC Box PC family with mounting bracket for front mounting in
portrait format

•
•
•
•
•

Long service life
Extra long spare parts availability
Adapted computing power
High system availability
Individually adaptable

6/28

Siemens ST 80 / ST PC · 2013

All SIMATIC Panels and IPCs are developed for especially
demanding environments and also for long service life. Spare
parts availability for many years secures use in sound solar and
photovoltaic systems.
• Rugged:
Ambient temperatures of 0 °C to +55 °C offer high flexibility in
the choice of installation location. Use of a TEK is recommended for increasing the temperature range
(see Chapter: Temperature Extension Kit).
• Innovative and flexible:
- We meet the ever-increasing demand for more computing
power by using the current generation of processors from
Intel®. Based on the current chipsets, devices are available
with CeleronM, Core2Solo, Core2Duo and Core2Quad. This
makes power-saving applications (e.g. simple data acquisition) just as possible as power-hungry applications (such
as the software PLC in real-time WinAC RTX) and server
systems.
- The SIMATIC IPCs fit into any control cabinet. Different
mounting methods enable a host of installation variants.
Optimized equipping of the Panels and IPCs for more system
availability is one of the simplest options for increasing productivity by means of reducing standstill times. Electromechanical
components often cause malfunctions in PCs. Since hard disks
and fans in the industrial PC usually operate continuously, they
are subject to an especially high rate of wear and tear. Software
options for diagnostics and data backup, such as SIMATIC IPC
DiagMonitor or SIMATIC IPC Image Creator, are particularly
effective here, in addition to the use of high-quality industrial
grade components.

© Siemens AG 2013

Customized Automation
Renewable energy
Wind farms

■ Overview

Wind farms
Wind farms can be used to produce electrical power in all
climatic zones, at sea, and in all types of terrain. The requirements regarding the control systems for wind turbines and wind
parks are as diverse as the installation locations.
These locations are increasingly difficult to reach. This means
the equipment must be completely maintenance-free. The
Industrial PCs of the 427 series can meet these requirements.
By selecting high-quality components and special production
procedures, all the SIMATIC IPCs and Panels can be used for
several years without requiring servicing.

■ Benefits

■ Application
All SIMATIC Panels and IPCs are developed for especially
demanding environments. The devices are optimally equipped
to deal with vibration in wind turbines: rugged enclosures,
special hard disk brackets, and interlocks are just a few
examples of standard features on SIMATIC devices.
• Rugged:
- The SIMATIC IPCs fit into any control cabinet. Different
mounting methods enable a host of installation variants.
Ambient temperatures of 0 °C to +55 °C are supported on
the IPC427C, with much higher temperatures in some applications. Use of a TEK is recommended for extreme temperatures (see Chapter: Temperature Extension Kit).
- Salt-laden atmospheres are hard on the devices. SIMATIC
Panels are also available in the IP65 type and are thus
eminently suitable for offshore use. Versions of the Microbox
427C also enable use in salt-laden atmospheres: this is
made possible by special paint processes that have been in
use for many years.
• Innovative and flexible:
We meet the ever-increasing demand for more computing
power by using the current generation of processors from
Intel®. Based on current chipsets, devices with Celeron M,
Core2 Solo, Core2 Duo and Core2 Quad are available. This
makes power-saving applications (e.g. simple data acquisition) just as possible as power-hungry applications (such as
the software PLC in real-time WinAC RTX) and server systems.
Optimized equipping of the IPC and the Panel for more system
availability is one of the simplest options for increasing productivity by means of reducing standstill times. Electromechanical
components often cause malfunctions in PCs. Since hard disks
and fans in the industrial PC usually operate continuously, they
are subject to an especially high rate of wear and tear. Software
options for diagnostics and data backup, such as SIMATIC IPC
DiagMonitor or SIMATIC IPC Image Creator, are particularly
effective here, in addition to the use of high-quality industrial
grade components.

6

SIMATIC IPC427C with expansion frame

•
•
•
•
•

Suitable for special temperature requirements
Maintenance-free for offshore use
Can handle high mechanical load
High system availability
Individually adaptable

Siemens ST 80 / ST PC · 2013

6/29

© Siemens AG 2013

Customized Automation
Automotive industry
HMI operator stations for the automobile industry

■ Overview

Operations computer: Unit operator panel and protective guard control
box (PGCB)

• Colors to complement design, also possible in customized
RAL colors
• Rugged and maintenance-friendly device design
• Very high EMC
• Distributed configuration for large machines and distributed
installations
• Optimized high-speed operator control thanks to:
- Reduced number of operator controls
- Optimum control element layout
- 24 V DC hardware
- Direct keys or high-speed PROFIBUS communication for
direct keys
• Use of high-capacity mass storage for large software applications
• Silicone-free device configuration
• Chemically-resistant surfaces (resistant to lubricants and
fillers, oils, etc., in particular)
• Welding sputter-resistant surface
• Project-specific software ready installed

■ Application
In automotive industry, the fault-free operation of production
facilities is of paramount importance. The requirements of industrial control enclosures in respect of impermeability to dust and
water, as well as those in respect of the management of the
internal heat balance are therefore very high. In addition to the
HMI IPC477C and HMI IPC577C, the HMI IPC677C and Flat
Panels are also suitable for use as operator PCs in the
automotive industry.

■ Design

The fully-equipped and wired turnkey solutions in a variety of
designs are ideal for the requirements of the automotive industry.

6

■ Benefits
• Modern design combined with outstanding functionality
• Increased heat dissipation thanks to ribbed aluminum profile
and backpanel heat sink
• Easy access to controls thanks to hinged front frame or hinged
backpanel
• Modular system for precise customization and tailoring to
Panel or Panel PC
• High-quality aluminum press-drawn section with clean
surface finish

6/30

Siemens ST 80 / ST PC · 2013

• The modular design with a variety of aluminum frame and
expansion profiles can support all required device combinations. A variety of operator stations appear in the overview:
- Modular aluminum control enclosure system for the combination of multiple HMI Panels, Panel PCs, and Simatic S7
PLCs
- Modular aluminum control enclosure system
for the combination of multiple HMI Panels
- Modular aluminum control enclosure system
for the installation of an HMI Panel or Panel PC
(see "Overview" figure bottom left)
• Can be accessed via hinged front frame or hinged backpanel
• Integrated support arm elements at the top and bottom for the
direct attachment of support arm couplings
• Integrated handle attachments facilitate handling and
underline the design image
Certifications/Approvals
• IP65
• NEMA 4/EEMAC Type 12
• cULus
• CE

© Siemens AG 2013

Customized Automation
Automotive industry
HMI operator stations for the automobile industry

■ Technical specifications
Examples from the automotive industry
Type

HMI operator control unit

Operator PC unit operator panel + PLC

SIMATIC HMI IPC677C

PC Box based on SIMATIC HMI IPC677C

•
•
•
•

• Core i7, 2.53 GHz, 4 GB RAM
• 250 GB HD,
• Without MPI/PROFIBUS +
2 x Ethernet interface 10/100 Mbit
• Europe default 230 V

Components
Computing unit

Front panel

Core i7, 2.53 GHz, 4 GB RAM
250 GB HD,
PROFINET + 2 x Ethernet interfaces 10/100 Mbit
Europe default 230 V

SIMATIC HMI IPC677C 15" Touch,
15" XGA 1024x768 resolution

Customized front with 2x6 control keys,
15“ XGA 1024x768 resolution
• PP17-I PROFIsafe
• PP17-II
• S7-400 configuration

Additional components

Additional components
Operator panel enclosure

CC-4000, mounted on stand

• VIP 6000 (upper part)
• IW 6900 (lower part)

Dimensions

578 x 764 x 183 mm

630 x 1870 x 636 mm

Operator panel

with slide-in label

–

Keyboard

Sasse stainless steel keyboard IP65

Sasse stainless steel keyboard IP65

Mouse

Track-Ball integrated in the keyboard

Optical mouse

Elements

3 x 3SB3 elements with labeling plates,
1 x Emergency Off,
1x machine circuit-breaker,
signal light processing possible

2 x 4 operator controls,
1 x Emergency Stop

Locking

• E1-locking for enclosure lock
• E7 key-operated switch

Customized enclosure lock

Mounting

Installation in operator panel enclosure
with electrical wiring

Installation in operator panel enclosure
with electrical wiring

Ventilation

–

–

Terminals

Use of 3-wire terminals

Use of Wago terminals

Core identification

Yes

Yes

Base profile

• Icotec
• RJ45 Ethernet port

• Icotec
• RJ45 Ethernet port

Software:

• Windows 7, MUI
• WinCC V7.x
• SIMATIC STEP 7 Prof V5.x

•
•
•
•
•
•

Type

Protective guard control box
(PGCB)

Components

• SIMATIC HMI KP8F
• SIMATIC ET200S
• SCALANCE X202 – 2P IRT
Ethernet switch

Additional components
Operator panel enclosure

AE housing

Dimensions

300 x 300 x 155 mm

Elements

•
•
•
•

Locking

Customized enclosure lock

Mounting

Installation in operator panel
enclosure with electrical wiring

Core identification

Yes

8 short-stroke keys
1 x emergency stop
3 x Siemens key switches
1 x signaling column

Windows 7, MUI
SIMATIC Softnet S7 for IE V 6.x
SIMATIC STEP 7 V 5.x
SIMATIC S7-Graph V 5.x
SIMATIC DistributedSafety V 5.x
InTouch Runtime V 9.x

6

■ More information
Quotation preparation
Product specification according to customer requirements.
Quotation preparation by SIMATIC HMI specialists,
specification of:
• Non-recurring costs
• Prototype costs
• Standard unit prices
• General conditions (product agreement)
There is a minimum annual quantity/purchase quantity
(minimum quantity per type: 20), which is agreed with the
customer for the project.
Customized products can only be ordered in conjunction
with a product agreement.
A customer-specific order number is allocated during the
product agreement process.
SIMATIC contacts in your area
http://www.siemens.com/automation/partners

Siemens ST 80 / ST PC · 2013

6/31

© Siemens AG 2013

Customized Automation
Automotive industry
Front panel 15" with motion keys at side

■ Overview

■ Design
• 2 x 6 function keys (24 V DC) on left and right of display
• Function keys connectable using non-interchangeable
terminals, e.g. using vacant inputs of a Push Button Panel to
the control
• Display surface resistant to welding beads
• USB interface at the front
• External dimensions and mounting cutout as for corresponding standard product
• IP65 degree of protection at the front

■ Technical specifications

Front panel 15" with function keys at side
for Panel PC in the automotive industry
The front panel 15.1" with arrow keys at side is designed as a
front unit for Panel PC. The arrow keys at the side allow intuitive
and direct activation of movements in the plant. The display is a
pure display unit, alphanumeric characters are entered using an
external keyboard and external pointing device.

■ Benefits
• Display unit with additional function keys for efficient and
direct activation of motions
• Display surface resistant to welding beads
• 24 V DC function keys for wiring to digital inputs of controller
• Non-interchangeable terminals

■ Application

Type

Front panel 15"
with lateral function keys

Display

15.1" TFT

Resolution (pixels)

1024 x 768 pixels

General features

As for 15.1" front panel
for HMI IPC677C

Special features
Interfaces

USB interface at the front

Connectable to Panel PC

HMI IPC477C, HMI IPC677C,
compact and distributed design

Number of keys

2 x 6 function keys (24 V DC)
on left and right of display,
wired to terminals

Modification possibilities
• Customized design
• Modification of front design

■ More information
Quotation preparation
Product specification according to customer requirements.
Quotation preparation by SIMATIC HMI specialists,
specification of:
• Non-recurring costs
• Prototype costs
• Standard unit prices
• General conditions (product agreement)

6

There is a minimum annual quantity/purchase quantity
(minimum quantity per type: 20), which is agreed with the
customer for the project.
Customized products can only be ordered in conjunction
with a product agreement.
A customer-specific order number is allocated during the
product agreement process.
SIMATIC contacts in your area
http://www.siemens.com/automation/partners
Application example: Operations computer in the automotive industry

The front panel for Panel PCs with function keys at the side is
designed for HMI operations in the automotive industry, e.g. as
a display for control computers.
The front unit as the display unit with function keys at the side is
always used if comprehensive inputs are necessary using an
external keyboard and pointing device, but where efficient
control of movements should be additionally possible using the
function keys assigned to the graphics and directly to the PLC.

6/32

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Customized Automation
Automotive industry
Mobile Panel 277 10" Remote Operate

■ Overview

Front view

■ Design

Rear view

• For high-contrast and clearly readable display of already
configured SIMATIC WinCC process pictures of a stationary
operator panel (e.g. with PC 677) without further configuring
and adaptation overhead
• Server and client optimized for the following resolutions:
- Remote Operate Server with 1024 x 768 pixels
- Remote Operate Client with 800 x 600 pixels.
• Features
- High-resolution display 10" SVGA
- Integral acknowledgment and stop button
(safety category 3 in accordance with EN 954-1)
- Rugged and double-panel enclosure
(drop height 1 m, complete IP65 degree of protection)
- Thin Client concept:
Communication with the higher-level operator station using
Remote Operate software and PROFINET

■ Application

Side view

User-friendliness and ergonomic use were consistent design
considerations. With its low weight and compact design, the
Mobile Panel sits comfortably in the hand.
The Mobile Panels are extremely impact-resistant thanks to the
double-panel design and the rounded enclosure shape. The
STOP button is protected by a "collar" against unintentional use
and against damage when dropped. Harsh industrial environments present no problems to the SIMATIC Mobile Panels with
their dust and spray-water-protected enclosures in degree of
protection IP65.
The Mobile Panel is simply connected wherever it is needed in
the plant. The rugged connection box with degree of protection
IP65 can be installed anywhere. It ensures fault-free connection
and disconnection during normal operation and thus enables
the operator-control locations to be easily and safely changed
when several connection points are available in a plant.
RO Client 800 x 600 pixels and RO Server 1024 x 768 pixels

The SIMATIC Mobile Panel 277 10" Remote Operate (RO) from
Siemens bridges the gap between flexible use through portability and ease of handling, and the benefits of a thin client
concept.

The cable is up to 25 meters in length and handles power
supply, transfer of the STOP and acknowledgment button
signals, and also data communication.
The device has no rotating media.

Existing WinCC configurations of a Panel PC 677 15" can be
represented with functional compatibility. Reliable data transfer
and short response times are guaranteed here. Operator input
using the touch screen is intuitive. The optional device holder
enables secure storage or stationary operation of the Mobile
Panel.
Siemens ST 80 / ST PC · 2013

6/33

6

© Siemens AG 2013

Customized Automation
Automotive industry
Mobile Panel 277 10" Remote Operate

■ Mode of operation
All applications are run on the the Remote Operate Server,
which in turn handles any control connection to the production
process. The user now decides which applications will be
operated and monitored from the Mobile Panel. The plant
operator hardly notices that he or she is now working on the main
operator station and no longer locally.

■ Technical specifications
Type

Mobile Panel 277 10"
Remote Operate

Display

10" touch screen SVGA with
800x600 pixels, TFT display with
65,536 colors

Operation

Touch screen with captive stylus
and stylus holder, three-level
acknowledgment button (deadman's switch) integrated into the
handle, stop button, function keys,
key-operated switches and backlit
pushbuttons as option. Suitable for
left and right-handed operation

Interfaces

Hardwired connection line to connection box Plus for PROFINET/
Ethernet and power supply
(e.g. Mobile Panel 277 PN)

Software

Remote Operate Client software
(Thin Client) on Windows CE 5.0,
function-compatible representation
of existing WinCC configurations/
software applications of an existing
server, e.g. PC677

Ambient conditions

Full IP65 degree of protection,
ambient operating temperature 0°C
to 40°C, drop height to 1.0 m

Certification

CE, cULus, C-Tick,
EMC compliance, prototype test
(BG/BIA or SIBE Switzerland)

In the accessories pack

CD-ROM, operating instructions,
programming manual for Remote
Operate Software

Options

Membrane function keys, access
control (key-operated switch),
buttons, handwheel

Weight

2.3 kg

The device does not process the data locally, but instead
accesses the data of up to ten selectable main operator stations
with the help of the pre-installed Remote Operate Client
software.
These main operator stations are, in turn, equipped with the
Remote Operate Server software. All stations are connected
via Industrial Ethernet.
The Mobile Panel is thus optimized exclusively on the visualization and management of the different stationary operator
stations.
Communication with the higher-level operator station takes
place via the Remote Operate software and is enabled via
PROFINET.

■ Function
• Automatic restart after switching on and display of the server
selection list (up to 4 hierarchical levels and up to 10 servers)
• Password protection
• Automatic Reconnect of client
• Operation authorization indication (traffic light) on the server
and client
Sophisticated safety concept
The Mobile Panel has an acknowledgement button (in accordance with EN 60204-1) with three switching steps. This can be
adjusted to an ergonomic position for both left-handed users
and right-handed users simply by turning.
The STOP pushbutton (acc. to EN 60204-1) can be looped into
the EMERGENCY OFF circuit of a machine and positively
latches when pressed. It is distinguished from an EMERGENCYOFF button by its gray color. This ensures that it cannot be
mistaken for the EMERGENCY-OFF equipment.

6

The STOP and acknowledgment buttons are implemented
as double circuits in accordance with Safety Category 3 to
EN 954-1.

6/34

Siemens ST 80 / ST PC · 2013

Type

PN Plus connection box

Interfaces

2 x Ethernet with 10/100 Mbit/s,
integrated switch

Expansion for operator-process communication

Reconnection during operation without interrupting the emergency stop
circuit, monitoring of the STOP button, location recognition (through
hardware)

■ Ordering data

Order No.

Mobile Panel 277 10"
Remote Operate
Configuration on request

6AV6645-7AB10-0AS0

Connection box PN Plus

6AV6671-5AE11-0AX0

Connecting cable
•5m
• 10 m
• 25 m

6XV1440-4BH50
6XV1440-4BN10
6XV1440-4BN25

© Siemens AG 2013

Customized Automation
Automotive industry
Mobile Panel 277 10" Remote Operate

■ More information
Customer-specific modifications
• Individual company logo instead of the Siemens logo and
changing the type designation
• Changing the keyboard colors, labeling, symbols and
background color
• Possible options: Membrane function keys, access control,
pushbuttons and handwheel

Quotation preparation
SIMATIC HMI specialists define the product modifications
precisely in accordance with customer requirements.
This is followed by drafting of a quote by SIMATIC HMI
specialists, determining the following:
• Non-recurring costs
• Prototype costs
• Standard unit prices
• and the marginal conditions in the form of a product
agreement (e.g. minimum quantity).
The defined device can be easily ordered using this product
agreement and a customized order number. Device fronts are to
be stored and provided by the customer upon delivery
completion.

6

Siemens ST 80 / ST PC · 2013

6/35

© Siemens AG 2013

Customized Automation
General machine construction
Front panel 15" Touch and Key for Panel PCs,
resistant to honing oil

■ Overview

■ Benefits
•
•
•
•
•

Combined Touch + Key operation for increased inefficiency
Touch pen operation avoids contamination of the display area
Ergonomically shaped touch pen which cannot be lost
Simple cleaning
Resistant to coolants and lubricants

■ Application
The front panel for Panel PCs with touch screen and membrane
keyboard has been designed for operator control and
monitoring at machine level for machine construction applications, where honing oil and lubricants are used.
The touch and key front is always used if efficient operation of
the machine is associated with the following requirements:
• Intuitive operation using graphic representation on display
• Specific command inputs using fixed command inputs
• Effective inputs in forms using the integrated numeric and
alphanumeric keyboard
Also in applications with increased environmental influences
such as dirt and oil. The homogenous foil surface without joints
or edges permits easy cleaning, and is resistant to coolants and
lubricants.
Application examples
• Printing machines
• Drilling, milling, honing machines
• Brake test stands
• Injection molding machines
• Building management
• Warehouse systems
• Automotive industry

■ Design
The Front Panel Touch and Key is designed as a front unit for
Panel PCs. The combination of Touch and Key operation as well
as the resistance to honing oil are characteristics of this product.

6

Complete lamination of the decoration foil over the touch area of
the display increases the resistance against contamination and
welding beads, and the absence of edges and joints facilitates
cleaning. Openings and cutouts in the front have been
completely omitted in favor of a homogenous surface which can
also be used in the environment of honing oil and similar cooling
agents and lubricants.
Clear operation is achieved using the Touch pen which is
delivered as standard and can be stored in a front holder. Dirty
or oily hands are therefore not an argument against using a
Touch screen. The pen has an ergonomic shape, is optimized for
operations when wearing gloves, and is linked to the front using
an elastic helix cable. Its "parking position" in the special
stainless steel holder on the front means that it is always readily
accessible.

6/36

Siemens ST 80 / ST PC · 2013

• External dimensions and mounting cutout as for corresponding standard product
• Degree of protection IP65 at the front

© Siemens AG 2013

Customized Automation
General machine construction
Front panel 15" Touch and Key for Panel PCs,
resistant to honing oil

■ Technical specifications

■ More information

Type

Front panel 15" Touch + Key,
resistant to honing oil

Display

15.1" TFT Touch

Resolution (pixels)

1024 x 768 pixels

General features

As front panel 15.1" Touch
for Panel PC 677

Special features
Interfaces

Without front-sided USB interface

Connectable to Panel PC

PC 477, PC 677 compact
and distributed design

Number of keys

58 system keys and
alphanumeric keys
20 function keys with LED

Resistance

Tested with:
Castrol Honilo 981 honing oil

Quotation preparation
Product specification according to customer requirements.
Quotation preparation by SIMATIC HMI specialists,
specification of:
• Non-recurring costs
• Prototype costs
• Standard unit prices
• General conditions (product agreement)
There is a minimum annual quantity/purchase quantity (minimum
quantity per type: 20), which is agreed with the customer for the
project.
Customized products can only be ordered in conjunction with a
product agreement.
A customer-specific Order No. is allocated during the product
agreement process.
http://www.siemens.com/automation/partners

6

Siemens ST 80 / ST PC · 2013

6/37

© Siemens AG 2013

Customized Automation
General machine construction
Flat Panels, 10.4" for Panel PC

■ Overview

■ Technical specifications

• Ideal for machine-level human machine interfacing
• Especially suitable for use in machines with restricted installation space
• Can be modified in design and front mechanical components
(e.g. stainless steel front for food and beverages industry)
• Distance between the Flat Panel and PC max. 30 m
• Functions correspond to the standard Flat Panels
• Available with and without touch operation
• VGA and SVGA resolution

■ Application
The Flat Panel 10.4" TFT Touch has been designed as display
and operator control unit for industrial PCs (e.g. SIMATIC
Microbox 427C) and Panel PCs (e.g. PC 677C) and can be
separated from the computing unit by up to 30 m.
They supplement the SIMATIC standard products and are
suitable for machine-level human machine interfacing when PC
functionality is required but little space is available for installing
a display. VGA and SVGA resolution also in a secondary display,
e.g. Panel PC 677C.

Flat Panel

10.4”

Resolution (pixels)

800 x 600 pixels

Input unit

Analog-resistive touch screen

MTBF (at 25 °C)

50 000 h

Power supply

24 V DC, RoHS

Front dimensions
(L x W x D in mm)

335 x 275 x 75

Installation dimensions
(L x W in mm)

310 x 248

Certified in accordance with
Can be connected to
Approx. weight in kg

0.80

■ Ordering data
Flat Panel 10" Touch

Order No.
6AV7461-7TA00-0AA1

SIMATIC Flat Panel 10.4" TFT
with analog-resistive Touch Panel,
resolution 800 x 600 pixels, 24 V DC
power supply, VGA, DVI-D interface,
incl. VGA cable 1.8 m

■ More information
Customized modification options
• Customized design
• Modification of front design, e.g. stainless steel front

6

6/38

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Customized Automation
Food and beverages industry/pharmaceuticals
Introduction

■ Overview
Hygiene areas in food and beverage production, pharmaceuticals or fine chemicals all share one requirement: The devices
and equipment must be easy to clean. The relevant directives,
standards and legislative requirements must be observed, e.g.
EHEDG, FDA, DIN EN 1672-2 (Hygienic Design), GMP, LMHV,
LMBG.
However, optimization and variation in the device hardware are
also perfectly possible:
• Degree of protection
• Ruggedness
• Temperature resistance
• Design and installation versions
• Suitable for clean rooms
• Certification in accordance with ATEX
The aim is to find the cost-optimized solution for the specific
application case.
The overview below shows different features depending on the
applications areas, from packaging to the wet area in
processing.
Applications
Features

Hygienic packaging

Pharmaceuticals,
fine chemicals

Food and beverages,
bottle cleaning,
bottle filling, laboratories

Abattoirs,
meat processing

Stainless steel front

partially

x

x

x

Stainless steel control boxes

x

x

x

x

Stainless steel fully enclosed

x

x

x

x

Simple to clean

x

x

x

x

No grooves and gaps,
no projections

partially

partially

membrane-covered
protective edge not
always accepted

-

Increased tightness

-

-

x

x

Mechanical ruggedness,
no membrane front

-

-

partially

x

Suitable for high-pressure cleaning
(IP69K)

-

-

-

partially

ATEX Ex Zone 2/22

x

x

partially

-

The product examples described on the following pages cover
a wide range of the most important requirements.

6

■ Benefits
• Simpler cleaning thanks to resistant and rugged stainless
steel front with smooth surface, and minimal grooves and
gaps
• High degree of protection IP66K (TP 177B and MP 277
additionally IP66K) on the front for increased sealing
properties and ruggedness
• Food-standard sealing material and shatter protection for the
display to prevent contamination of the foodstuffs
• Optimized frame design almost flush with the control cabinet
so that liquids can run off
• Device front developed on the basis of DIN EN 1672-2
• Decorative membrane tested against chemicals in accordance with DIN 42115, Part 21)
• Food-standard flat seal in accordance with
FDA 21 CFR 177.2006
• Rear tensioning frame (included in scope of supply) for even
application pressure of the seal
• External dimensions and mounting cutout as for corresponding standard product
1)

High degree of protection for humid environments
With low installation depth and rugged front, the SIMATIC HMI
Standard Panels are eminently suitable for industrial and
machine-level use.
The Panels with stainless steel front are also even better
equipped to meet the high requirements presented by the food
and beverage production environment. IP66K degree of
protection protects against water even with a jet strength of
100 l/min at 10 bar from a distance of 2.5 m to 3 m. The
optimized frame profile and almost flush-mounting of the device
on the control cabinet allow liquids to run off.
Installation of the operator panels in a stainless steel control
cabinet as ready-to-use units is optionally available as a
customized version.

Special resistance requirements must be examined separately.

Siemens ST 80 / ST PC · 2013

6/39

© Siemens AG 2013

Customized Automation
Food and beverages industry/pharmaceuticals
Introduction

■ Benefits (continued)
Certificates, listings and appraisals
SIMATIC HMI products with stainless steel front, and the
stainless steel operator panel, were subjected to some or all of
the tests below and are listed or appraised in accordance with:
• High degree or protection IP66K, NEMA Type 4, 4x, 12
• CE-compliant, cULus-listed
• LGA mark "Hygiene tested"
(Approval document No. 5664018)
• Expert appraisal of the Munich University of Technology,
Research Center Weihenstephan, in accordance with EHEDG
recommendation (Report No.126/01.03.2007)
• Clean room qualification by IPA Fraunhofer Institute
(test report: Examination of the clean room suitability and
ESD characteristics of Panel PCs from Siemens AG,
Report No. SI 0810-450 of October 2008)
Qualification for clean rooms
High-quality products such as semiconductors, medicines,
food & beverages, and nanotechnology products are subject to
special demands with regard to contamination with particles or
bacteria.
Increased requirements for protection of the products and
processes can only be met by production in clean rooms with
suitable equipment under controlled conditions.
Clean rooms are classified according to particle quantities and
sizes per m3 of room air and time unit. Clean room classes in
accordance with ISO 14644-1 (ISO 1 to 9) have been introduced
in pharmaceuticals, for example, in accordance with EG-GMP,
Annex 1 (Classes A to F), and in semiconductor production.

6

Example:
A person in normal clothing emits approximately
80,000 particles >= 0.5 mm per second
(in clean room clothing, this can be reduced to
approximately 700 particles/s >= 0.5 mm).
• Requirements regarding equipment in clean rooms include
the following:
• Surfaces that are easy to clean and disinfect
• As few adhesives as possible, e.g. electrostatic
• No emitting surfaces
• Shape favorable to air circulation, no air eddies
• Dense, as few hollow or dead spaces as possible
• Smooth, as few grooves and gaps as possible
The SIMATIC HMI products with stainless steel front and the
stainless steel operator panel have been designed for these
requirements.
The stainless steel operator stations with Panel PC 677B
15" Touch INOX and MP 377 15" Touch INOX have been tested
by the Fraunhofer Institute and qualified for "obvious suitability
for clean rooms of ISO Class 1 in accordance with
DIN EN ISO 14644-1".

6/40

Siemens ST 80 / ST PC · 2013

■ Application
Quality and hygiene are decisive competitive features in the
production of food and beverages. In addition, higher volumes
have to be produced in shorter times and with rising quality
demands.
Objects and equipment that come into contact with food and
beverages must be
• such that they are clean and can be maintained and, if
necessary, disinfected, and have no adverse effect on the
food and beverages
• installed in such a way that the immediate environment can be
cleaned appropriately.
Objects and equipment must be clean and well maintained
(extract from the German food and beverages hygiene legislation). This requires not only the innovative know-how of
engineering offices, mechanical equipment manufacturers and
plant builders, but also modern, powerful human machine
interface systems whose hardware and software are adapted to
the special requirements.
The SIMATIC Panels and Panel PCs with touch screens and
stainless steel fronts have been designed for use in the food,
beverages and tobacco industry and for operator control and
monitoring close to food processing machines. For this reason,
the devices with stainless steel front have been developed in
compliance with DIN EN 1672-2 "Food processing machinery –
Safety and Hygiene Requirements".
Simpler cleaning and disinfecting
The high quality requirements in the food and beverages
industry require a high standard of the food processing
machinery. There are many relevant regulations, directives,
ordinances, standards and laws. Essential here is that all
equipment and components must be easy to clean and disinfect
so that cross-contamination of the foodstuffs can be avoided.
The Panels with stainless steel front have a 240 grit hairline
finish, so they are suitably smooth. The membrane covering the
display cutout is tested with regard to its resistance to
chemicals, has minimal grooves and gaps in which microorganisms could settle, and also provides shatter protection for
the display.

© Siemens AG 2013

Customized Automation
Food and beverages industry/pharmaceuticals
Panels and Panel PCs with stainless steel front

■ Overview
TP 177B color PN/DP, MP 277 10" Touch, MP 377 15" Touch
and Panel PC 677B 15"
The SIMATIC Panels with touch screens and stainless steel
fronts have been designed for use in the food, beverages and
tobacco industry for operator control and monitoring close to
food processing machines. They have been developed in
compliance with DIN EN 1672-2 "Food processing machines –
Safety and Hygiene Requirements".
• Simple cleaning and disinfecting
- Stainless steel surface with 240 grade hairline finish
- Membrane tested for resistance to chemicals
- Minimal number of grooves and joints
- Optimized frame profile so that liquids can run off
• Display shattering protection
• Degree of protection IP66K

■ Design
• External dimensions and mounting cutout as for corresponding standard product
• Optimized frame profile with a slight projection to the cabinet
• IP66K degree of protection at the front
• Surface ground with 240 grain abrasive
• Minimal number of grooves and joints

•
•
•
•

Decorative film tested for resistance to chemicals
Display splash protection
Food-standard seals
Rear tensioning frame for even application pressure of the
seal

■ Technical specifications
Multi Panels
MP 277 10" Touch INOX

MP 377 15" Touch INOX

Power supply

24 V DC

24 V DC

Display

10.4" color TFT Touch

15.1" TFT Touch

Resolution (pixels)

640 x 480

1024 x 768

MTBF of backlighting (at 25 °C)

about 50 000 hours LED backlighting

about 50 000 hours CCFL backlighting

General features

Front
Material

Stainless steel 1.4301, polyester-based membrane

Surface

Hairline finish, 240 grit abrasive grain

Device seal

EPDM flat seal

6

Special features
Ambient conditions
Degree of protection

on the front: IP66K, NEMA 4, 4x and 12; on the rear: IP20

Ambient temperature during operation

0 ... 50 °C

Relative humidity

max. 85% (no condensation)

Transport/storage temperature

-20 °C to +60 °C

Approvals

FM Class 1 Div 2, cULus, CE, C-Tick, ATEX Zone 2/22

Sector

Food & beverages, pharmaceuticals

Food & beverages, pharmaceuticals

WinCC flexible 2005 Standard and higher

WinCC flexible 2007 Standard and higher

External dimensions
(W x H x D in mm)

325 x 263

400 x 310

Installation cutout (W x H x D in mm)

310 x 248

368 x 290

Special features

Clamping frame

Clamping frame

Weight

Approx. 4.2 kg

Approx. 6.2 kg

HMI software
(to be obtained separately)
HMI engineering software
Dimensions

Siemens ST 80 / ST PC · 2013

6/41

© Siemens AG 2013

Customized Automation
Food and beverages industry/pharmaceuticals
Panels and Panel PCs with stainless steel front

■ Technical specifications (continued)
Panel PC

Panels

Panel PC 677B 15" Touch INOX

TP 177B PN/DP INOX

Power supply

100/230 V AC (autorange), 50/60 Hz or 24 V DC

24 V DC

Display

15.1" TFT Touch

5.7" color STN Touch (256 colors)

Resolution (pixels)

1024 x 768

320 x 240

MTBF of backlighting (at 25 °C)

about 50,000 hours CCFL backlighting

Special features

Without front USB interface

General features

1 x emergency-off, 3 x short-stroke membrane keys with
LED on front, wired to terminal

Front
Material

Stainless steel 1.4301, polyester-based membrane

Surface

Hairline finish, 240 grit abrasive grain

Device seal

EPDM flat seal

Special features

on the front: IP66K, NEMA 4, 4x and 12; on the rear: IP20

Decorative membrane drawn across the display

Degree of protection

on the front: IP66K, NEMA 4, 4x and 12; on the rear: IP20

on the front: IP66K, NEMA 4, 4x and 12; on the rear: IP20

Ambient temperature during operation

0 ... 50 °C

0 ... 50 °C

Relative humidity

max. 85% (no condensation)

Transport/storage temperature

-20 °C to +60 °C

Approvals

CE, cULus

FM Class 1 Div 2, cULus, CE, C-Tick, ATEX Zone 2/22

Sector

Food & beverages, pharmaceuticals

Food & beverages, pharmaceuticals

HMI engineering software

WinCC flexible Advanced and higher

WinCC flexible 2005 Compact and higher

HMI Runtime software

WinCC flexible RT

Ambient conditions

HMI software
(to be obtained separately)

Dimensions
External dimensions
(W x H x D in mm)

483 x 310

212 x 156

Installation cutout (W x H x D in mm)

450 x 296

198 x 142

Special features

Clamping frame

Clamping frame

Can be connected to SIMATIC PC

On Panel PCs as well as other SIMATIC Rack and Box
PCs

Weight

Approx. 15 kg

6

6/42

Siemens ST 80 / ST PC · 2013

Approx. 1.5 kg

© Siemens AG 2013

Customized Automation
Food and beverages industry/pharmaceuticals
Panels and Panel PCs with stainless steel front

■ Ordering data
TP 177B color PN/DP INOX

Order No.
6AV6642-8BA10-0AA0

with stainless steel front,
otherwise corresponding to
6AV6642-0BA01-1AX0
MP 277 10" Touch INOX

6AV6643-0ED01-2AX0

with stainless steel front and LED
backlight, otherwise corresponding
to 6AV6643-0CD01-1AX1
MP 377 15" Touch

6AV6644-0CB01-2AX0

with stainless steel front and LED
backlight; otherwise corresponding
to 6AV6644-0AB01-2AX0
Panel PC 677B 15"
with stainless steel front, otherwise
corresponding to Panel PC 677B
Configurator 6AV6643-0CD01-1AX1

6AV7872-2…

■ More information
Customized modification options
• Customized design
- Use of the company name instead of the Siemens logo and
modification of the type designation
- Changing the background color
• Customer-specific hardware modifications such as the design
and dimensions of the front plate, selection of the display,
memory capacity, drives, options
• Customer-specific Panel PC configuration as a rugged
embedded hardware and software system, without hard disk
and with tailor-made software
• Customer-specific software suite with choice of Windows
operating systems
• Customer-specific Panel PCs with software suite with choice
of Windows operating systems
• Protection against condensation and corrosive gases
(for selected panels)
• Device mounted in a stainless steel cabinet as a ready-toinstall and ready-to-connect terminal which is ergonomic,
functional, with high degree of protection as well as tested
heat dissipation (e.g. with complete degree of protection
IP66K)
Drafting a quotation
SIMATIC HMI specialists define the product modifications
precisely in accordance with customer requirements.
This is followed by drafting a quotation with:
• Non-recurring costs
• Prototype costs
• Standard unit prices
• and the marginal conditions in the form of a product
agreement (e.g. minimum quantity).
The defined device can then be easily ordered using this
product agreement and a customized Order No.

6

Siemens ST 80 / ST PC · 2013

6/43

© Siemens AG 2013

Customized Automation
Food and beverages industry/pharmaceuticals
HMI Panels as rear-mounted devices

■ Overview

■ Design

MP 377 12" Touch, rear-mounting

The front frame is modified customer-specifically on the
"rear-mounting devices":
The surface with the display viewing area covered with
decorative membrane, and the marginal area around the display
necessary for touch operation must be flush with the control
cabinet sheet metal at the front. For this purpose, the front frame
with the device seal and the cutouts for the holding bolts are set
back from the visible surface by the thickness of the control
cabinet sheet metal. The enclosure must have a suitable number
of stud bolts available. The all-round device seal thus enables a
high degree of protection: IP65.
The installation cutout can be dimensioned in such a way that
the rear-mounting device can be replaced with the same type of
front-mounting device for service purposes.

MP 277 8" Touch vertical, rear-mounting

MP 377 12" Touch, rear-mounting,
MP 277 8" Touch vertical, rear-mounting

6

The solution for installing HMI devices without "corners and
edges" on the front. The devices are installed in the control
cabinet enclosure from the rear and are flush with the control
cabinet sheet metal at the front. They are therefore known as
"rear-mounting devices".

■ Benefits
•
•
•
•

Front surface flush with the control box
Simple to clean
No dirt-collecting edges and deposits
Front membrane resistant to the usual cleaning agents and
disinfectants
• Can be replaced with front-mounting device of the same type
for service purposes (MP 377 12" Touch rear-mounting only)

6/44

Siemens ST 80 / ST PC · 2013

The decorative membrane is also drawn across the visible area
of the display on the rear-mounting devices, so there is no cutout
with adhesive edge above the display. The decorative
membrane is smooth.
For sensitive applications where the gap dimension of the
control cabinet cutout has too great a tolerance, there is the
option of covering the entire surface including the gap with a
transparent and replaceable membrane.

© Siemens AG 2013

Customized Automation
Food and beverages industry/pharmaceuticals
HMI Panels as rear-mounted devices

■ Technical specifications
MP 277 8" Touch vertical, rear-mounting

MP 377 12" Touch, rear-mounting

Power supply

24 V DC

24 V DC

Display

7.5" TFT Touch

12.1" TFT Touch

Resolution (pixels)

480 x 640 (portrait)

800 x 600

MTBF of backlighting (at 25 °C)

about 50,000 hours CCFL backlighting

Special features

1 x emergency-off, 3 x short-stroke membrane keys with LED on front, wired to terminal

General features

Front
Material

Aluminum under polyester-based membrane

Surface

Hairline finish, 240 grit abrasive grain

Device seal

On the enclosure, customized

Special features

Decorative membrane drawn across display

On the front

Ambient conditions
Degree of protection

IP65 at front; IP20 at rear

Ambient temperature
during operation

0 ... 50 °C

Relative humidity

max. 85% (no condensation)

Transport/storage temperature

-20 °C to +60 °C

Approvals

CE

Sector

Food & beverages, packaging systems, pharmaceuticals

CE, cULus

HMI software
(to be obtained separately)
HMI engineering software

From WinCC flexible 2007
Standard with add-on for portrait format

WinCC flexible 2007 Standard and higher

External dimensions
(W x H x D in mm)

229 x 318

As installation cut-out

Installation cutout (W x H x D in mm)

233 x 322 x 67

Compatible with standard device

Special features

Rear-mounting panel in portrait format

Rear-mounting panel; panel cutout as on standard device

Weight

Approx. 2.7 kg

Approx. 5.5 kg

Dimensions

■ Ordering data
MP 377 12" Touch, rear-mounting

Order No.
6AV6644-…

Configuration on request
MP 277 8" Touch vertical,
rear-mounting
With emergency-off button and
3 short-stroke keys with LEDs
on the front
Configuration on request

6AV6643-…

■ More information
Customized modification options
Customized rear-mounting versions can also be implemented:
• Customized operator controls possible on the front,
e.g. membrane keys, emergency-off
• Adaptation to the design of the customized enclosure
• Customized design (logo and color scheme) on the front
membrane
• Portrait mode of the display
• Increased resistance to shock and machine vibration
Quotation preparation
SIMATIC HMI specialists define the product modifications
precisely in accordance with customer requirements.
This is followed by drafting of a quote with:
• Non-recurring costs
• Prototype costs
• Standard unit prices
• and the marginal conditions in the form of a product
agreement (e.g. minimum quantity).
The defined device can then be easily ordered using this
product agreement and a customized order number.

Siemens ST 80 / ST PC · 2013

6/45

6

© Siemens AG 2013

Customized Automation
Food and beverages industry/pharmaceuticals
Flat Panels with stainless steel front

■ Overview

■ Design
• Functions compatible with the SIMATIC HMI Standard Flat
Panels
• Enclosure seal EPDM, sulfur-free
• Decorative membrane laminated over display, no display
cutout
• 240 grain brushed stainless steel surface
The Flat Panels 15" Touch INOX and 19" Touch INOX VESA are
fully enclosed and are suitable for space-saving mounting on a
support system. The cables are then run in the supporting tube.

Flat Panel 15" Touch INOX,
Flat Panel 15" Touch INOX (enclosed),
Flat Panel 19" Touch INOX,
Flat Panel 19" Touch INOX (enclosed)
The Flat Panels with touch screen and stainless steel front are
designed as a display and operating unit for SIMATIC PCs in the
food and beverages industry, pharmaceuticals and related
industries.
They are easy to clean and can be installed in production areas
subjected to splashes in a suitable control cabinet.

6

6/46

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Customized Automation
Food and beverages industry/pharmaceuticals
Flat Panels with stainless steel front

■ Technical specifications
Flat Panel
15" Touch, INOX

15" Touch INOX
fully enclosed

19" Touch, INOX

19" Touch INOX
fully enclosed

General features
Power supply

24 V DC

24 V DC

24 V DC

24 V DC

Display

15.1" TFT Touch

15.1" TFT Touch

19.1" TFT Touch

19.1" TFT Touch

Resolution (pixels)

1024 x 768

1024 x 768

1280 x 1024

1280 x 1024

MTBF of backlighting (at 25 °C)

approx. 50 000 hours CCFL backlighting

Special features

Without front USB interface

Without front USB interface

OSD operation not
accessible; values preset

EPDM flat seal

EPDM flat seal

OSD operation not
accessible; values preset

Front
Material

Stainless steel 1.4301, polyester-based membrane

Surface

Hairline finish, 240 grit abrasive grain

Device seal

EPDM flat seal

Special features

Decorative membrane drawn across display

Ambient conditions
Degree of protection

On the front: IP66K,
NEMA 4, 4x and 12;
on rear: IP20

Complete IP65,
NEMA 4

On the front: IP66K,
NEMA 4, 4x and 12;
on rear: IP20

Complete IP66K,
NEMA 4, 4x and NEMA 12

Ambient temperature
during operation

0 ... 50 °C

0 ... +40 °C at an angle of
up to +/- 20° from the vertical

0 ... 50 °C

0 ... +40 °C

Relative humidity

Max. 85% (no condensation)

Transport/storage temperature

-20 °C to +60 °C

Approvals

CE, cULus

CE, cULus

CE, cULus

CE, cULus

Sector

Food & beverages,
pharmaceuticals

Pharmaceuticals

Food & beverages, pharmaceuticals

Food & beverages, pharmaceuticals

External dimensions
(W x H x D in mm)

483 x 310

383 x 324 x 72

483 x 400

483 x 399 x 61

Installation cutout (W x H x D in mm)

450 x 296

Special features

Clamping frame

Tiltable customized flange
for mounting on control
cabinet, sealed by bellows

Clamping frame

fully enclosed, VESA 100

Weight

Approx. 7 kg

Approx. 12 kg

Approx. 10 kg

Approx. 12 kg

Dimensions

■ Ordering data

Order No.

Flat Panel 15" Touch INOX

6AV7486-2TA10-1AA0

Flat Panel 15" Touch INOX
fully enclosed

6AV7476-...

Configuration on request
Flat Panel 19" Touch INOX

6AV7486-4TA01-0AA0

Cable 1.8 m pre-assembled

■ More information

6

Customized modification options
• Customized design
• Customized flange connection
• Cable length up to 30 m
Drafting a quotation

Cable 1.8 m enclosed
Flat Panel 19" Touch INOX
fully enclosed

450 x 380

6AV7486-4TA11-0AA0

SIMATIC HMI specialists define the product modifications
precisely in accordance with customer requirements.
This is followed by drafting a quotation with:
• Non-recurring costs
• Prototype costs
• Standard unit prices
• and the marginal conditions in the form of a product
agreement (e.g. minimum quantity).
The defined device can then be easily ordered using this
product agreement and a customized order number.

Siemens ST 80 / ST PC · 2013

6/47

© Siemens AG 2013

Customized Automation
Food and beverages industry/pharmaceuticals
HMI stainless steel operator stations

■ Overview

■ More information
Customized modification options
• Other HMI devices, display sizes and resolutions
• External stainless steel keyboard, e.g. without short-stroke
keys with piezo technology
• Modification of the front/enclosure design
(hygiene test optional) and cable routing
• Specific flange from enclosure manufacturers
• Breather gland
• Use in extended ambient temperature range,
e.g. -20 °C to +60 °C
- Air-water heat exchanger (internal)
- "Temperature Extension Kit" plus active heating and cooling
elements

SIMATIC HMI Panels or Panel PCs mounted in a stainless steel
cabinet as a ready-to-install and ready-to-use terminal that is
ergonomic and functional, and has a high degree of protection
(complete degree of protection IP66K) as well as tested heat
balance.
The populated and wired turnkey solutions are based on the
hygienic design requirements of the food and beverages
industry as well as other hygiene and wet areas, pharmaceuticals, fine chemicals and semiconductor production.

■ Design
• Control box completely assembled, wired, tested,
with passive cooling
Design of stainless steel terminal
• For Panels and Panel PCs
• Angular surfaces so that liquids can run off
• Prepared for stand mounting
• With integrated handles at sides.

6

High complete degree of protection
• Screwed-on rear panel
• Cable inlet through stand and flange
Simple to clean
• No sharp corners or edges
• No dead spaces
• Hairline finish of surface with 240 grade grain

6/48

Siemens ST 80 / ST PC · 2013

Certification/approvals
• LGA Certificate "Hygiene-tested"
• Inspection certificate of the Munich University of Technology
• IPA Fraunhofer Institute
These modifications are defined by HMI specialists in consultation with the customer who then receives a specific offer.
A product agreement with minimum quantities is required for the
implementation of customized modifications. Please contact
your local/national Siemens HMI representative.

© Siemens AG 2013

Customized Automation
Oil & gas/chemicals/shipbuilding
Oil & gas/chemicals/shipbuilding

■ Overview
The requirements of the sectors oil and gas, chemicals and
shipbuilding are diverse and range from use in areas subject to
explosion hazard involving drill pipes, use in the extended
temperature range (outdoor) and in direct sunlight, all the way to
use on the darkened bridge of a ship.

The following features are required in shipbuilding:
• Dimmable display down to complete black-out
• Marine Type certification such as Germanischer Lloyd and
others

In the case of drill pipes in the oil and gas industry and also in
the chemicals industry, the following product features are
important:
• Certification for areas subject to explosion hazard in Zones 2
and 22 in accordance with ATEX, FM Class I, Div. 2 and
UL Haz. Loc.
• Daylight-readable display
• Use in sub-zero temperatures and in regions with high
atmospheric humidity
• Resistant to harsh environmental conditions
• Stainless steel surfaces are demanded for increased resistance to chemicals

HMI sector products
• MP 377 15" Touch daylight readable

6

Siemens ST 80 / ST PC · 2013

6/49

© Siemens AG 2013

Customized Automation
Oil & gas/chemicals/shipbuilding
MP 377 15" Touch daylight readable

■ Overview

6

■ Design

• Ideal for use in the oil & gas industry:
- Certification in accordance with ATEX for Zone 2/22,
UL Haz. Loc.,
- FM Class I, Div.2
- Bright, daylight-readable display
- Rugged front for harsh environmental conditions
- UV-protected decorative membrane
- High degree of protection
- Can be used in the extended outdoor temperature range at
-30 °C to +70 °C with the TEK option in an air-conditioned
control cabinet
• Ideal for use in shipbuilding:
- Diverse shipbuilding certificates (available soon)
- 100% dimmable display backlighting, local and centralized
- Console installation without special measures or restrictions
- High-contrast display with wide reading angle
- Design version with black frame possible
• Features:
- Daylight-readable, bright and dimmable LCD display
- Splashwater-protected (IP66)
- Rugged aluminum front, impact-resistant, UV-protected
- Capacitive touch with 3 mm glass for harsh environmental
conditions
- Touch operation with thin gloves
- Outdoor applications with extended temperature range
(option)
- ATEX Zone 2/22, FM Class I, Div. 2, UL Haz. Loc.
- Marine certificates:
DNV, GL, NK, ABS, LRS, CCS, RINA
- Fan-free

■ Benefits
• A panel for applications inside and outside the production hall
• Extremely easy to read under diverse conditions
• Ergonomic dimmer function for optimal reading in control
desks
• Can be connected to centralized dimming potentiometer
(via PLC)
• Familiar HMI functions (exception: Sm@rt option and
high-speed keys), no new training

■ Application
The Panel has a daylight-readable and dimmable display,
making it predestined for use in control desks for, e.g. drill
strings (oil & gas industry), ships (shipbuilding) and other
exposed areas up to outdoor applications with the
TEK Temperature Extension Kit option.

6/50

Siemens ST 80 / ST PC · 2013

The "MP 377 15" Touch daylight readable" has a powder-coated
milled aluminum front that is impact-resistant, scratch-proof and
highly resistant to chemicals.
Touch operation uses projected capacitive technology
protected against humidity, heat and dirt in harsh environments
by a 3-mm pane of glass, without reflective membranes.
The refined polyester-based decorative membrane is
UV-resistant and protected against yellowing and embrittling.
The LED-backlit and dimmable display is designed using transflective technology that allows a higher contrast than conventional, transmissive displays in extremely bright environments.
The LED backlighting is dimmable using a slider on the process
picture or centrally via the controller. Dimming is carried out
using a gradation curve and is thus optimally ergonomically
matched to the human eye.
The Panel is based on the field-proven electronics card of the
MP 377 with WinCC flexible functionality and the familiar interfaces. The entire mechanical design is prepared for good
convection and temperature balance, for long service life, and
for operation onboard ship, or other vehicles with corresponding
shock and vibration stresses.

© Siemens AG 2013

Customized Automation
Oil & gas/chemicals/shipbuilding
MP 377 15" Touch daylight readable

■ Technical specifications
Multi Panels

■ Ordering data
MP 377 15" Touch
daylight readable

General features

Order No.

MP 377 15" Touch
daylight readable

6AV6644-8AB20-0AA1

Multi Panel 15" Touch with display
suitable for natural-light viewing

Display

15" TFT, transflective

Brightness

typ. 800 cd/m2

Contrast

typ. 1000:1

Reading angle

160°

Resolution

1024 x 768

MTBF of backlit display (at 25°C)

50,000 hrs LED backlighting,
dimmable 0 (off) to 100%

Input unit

Touch, projected capacitive

Drafting a quotation

Power supply

24 V DC, typ. 1.5 A

Special features

Daylight-readable

SIMATIC HMI specialists define the product modifications
precisely in accordance with customer requirements.

Front
Material

Aluminum, Autotex XE, glass

Surface

Powder-coated aluminum, polyester-based decorative membrane,
glass (Mohs 7)

Device seal

HC / EPDM 4x4

Ambient conditions
Degree of protection

Front IP66, rear IP20

Ambient temperature during operation

Front -30 °C to +70 °C, rear 0 °C to
+50 °C, changeover time >= 3 min.

Relative humidity

10% to 90%, without condensation

Vibration

IEC 60068, Part 2–6 (sine),
constant acceleration 1 g

Shock

IEC 60068, Part 2–29, 15 g peak
value, 11 ms duration

Transport and storage conditions

IEC 60721-3-2, Class 2M2

Transport/storage temperature

-40 °C to +80 °C

Approvals

CE, cULus, C-Tick, ATEX Zone 2/22,
UL haz. loc., FM Class I, Div. 2, shipbuilding certificates available soon

Sector

Oil & gas, ship, outdoor

Can be connected to SIMATIC PC

Multi Panels

■ More information
Customized modification options
• Integration into customized turnkey operator panels
• Customized design

This is followed by drafting a quotation with:
• Non-recurring costs
• Prototype costs
• Standard unit prices
• and the marginal conditions in the form of a product
agreement (e.g. minimum quantity).
The defined device can then be easily ordered using this
product agreement and a customized Order No.

HMI software
HMI engineering software

Configurable from WinCC flexible
2008, SP1 with add-ons

6

HMI Runtime software
Special features

Console mounting with an inclination
of up to 90°, installation cutout as on
MP 377 15" Touch (W x H)

Dimensions
External dimensions (W x H x D in mm)

400 x 315.5 x 106

Installation cutout (W x H x D in mm)

365.6 x 287 x 100

Weight

4.6 kg

Siemens ST 80 / ST PC · 2013

6/51

© Siemens AG 2013

Customized Automation
Notes

6

6/52

Siemens ST 80 / ST PC · 2013

7

© Siemens AG 2013

Appendix
7/2
7/3

Siemens Industry Training
Course overview

7/4

Standards and approvals

7/5

Partners at Industry Automation and
Drive Technologies
Siemens contacts worldwide
WinCC Competence Centers
Solution Partner

7/5
7/6
7/7
7/8
7/8
7/10
7/10
7/11

Siemens Automation Cooperates
with Education
Applicable practical know-how
Online Services
Information and Ordering in the Internet
and on DVD
Information and Download Center
Social Media, Mobile Media

7/12
7/13

Industry Services
For the entire life cycle

7/17

Siemens Service Option
for SIMATIC PC / PG

7/18

Expertise and services relating to
all aspects of PC-based Automation

7/19

Software Licenses

7/21

Index

7/25

Order No. Index

7/27

Length key for connecting cables

7/28

Catalog improvement suggestions

7/32

Conditions of sale and delivery

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Appendix
Siemens Industry Training
■ Faster and more applicable know-how:
Hands-on training from the manufacturer
Siemens Industry Training provides you with comprehensive
support in solving your tasks.
Training by the market leader in the industry enables you to
make independent decisions with confidence. Especially where
the optimum and efficient use of products and plants are concerned. You can eliminate deficiencies in existing plants, and
exclude expensive faulty planning right from the beginning.

■ Highlights Siemens Industry Training
Top trainers
Our trainers are skilled teachers with direct practical experience.
Course developers have close contact with product development, and directly pass on their knowledge to the trainers.
Practical experience
The practical experience of our trainers enables them to teach
theory effectively. But since theory can be pretty drab, we attach
great importance to practical exercises which can comprise up
to half of of the course time. You can therefore immediately implement your new knowledge in practice. We train you on stateof-the-art methodically/didactically designed training equipment. This training approach will give you all the confidence you
need.
Wide variety
With a total of about 300 local attendance courses, we train the
complete range of Siemens Industry products as well as interaction of the products in systems.
Tailor-made training
We are only a short distance away. You can find us at more than
50 locations in Germany, and in 62 countries worldwide. You
wish to have individual training instead of one of our
300 courses? Our solution: We will provide a program tailored
exactly to your personal requirements. Training can be carried
out in our Training Centers or at your company.

First-class know-how directly pays for itself: In shorter startup
times, high-quality end products, faster troubleshooting and reduced downtimes. In other words, increased profits and lower
costs.
Achieve more with Siemens Industry Training
• Shorter times for startup, maintenance and servicing
• Optimized production operations
• Reliable configuration and startup
• Minimization of plant downtimes
• Flexible plant adaptation to market requirements
• Compliance with quality standards in production
• Increased employee satisfaction and motivation
• Shorter familiarization times following changes in technology
and staff

■ Contact
Visit our site on the Internet at:
www.siemens.com/sitrain
or let us advise you personally.

7

Siemens Industry Training Customer Support Germany:
Phone: +49 (911) 895-7575
Fax:

+49 (911) 895-7576

E-Mail: info@sitrain.com

7/2

Siemens ST 80 / ST PC · 2013

The right mixture: Blended learning
"Blended learning" is a combination of various training media
and sequences. For example, a local attendance course in a
Training Center can be optimally supplemented by a teach-yourself program as preparation or follow-up. Additional effect:
Reduced traveling costs and periods of absence.

© Siemens AG 2013

Appendix
Siemens Industry Training
■ Training offer for SIMATIC HMI
This page contains an overview of the SITRAIN training offer for
SIMATIC HMI operator control and monitoring systems as well as
for PC-based Automation.
Depending on your demands we’ll make you fit for specific applications or teach you important background knowledge about
products and systems.
All courses contain the largest possible share of practical exercises so that training can be carried out very intensively in very
small groups.
Further information regarding course contents, dates and prices
can be found in the Internet at:
www.siemens.com/sitrain

■ SITRAIN courses for SIMATIC HMI / PC-based Automation
Commissioning engineers,
configuration engineers
Programmers

Service personnel

Project managers, project team members

Operators, users

Decision makers, sales personnel
Title

Maintenance personnel
Target Group

Duration/
Medium

Short title

■ SIMATIC WinCC based onTIA Portal
✔

✔

✔

✔

✔

3 days

TIA-WCCSUP

✔

✔

✔

✔

✔

3 days

TIA-WCCM

✔

✔

✔

✔

✔

5 days

TIA-WCCS

✔

✔

✔

✔

✔

WBT

WT-TIAWMUP

SIMATIC WinCC flexible, system course 1

✔

✔

✔

✔

✔

3 days

ST-WCCFSYS1

SIMATIC WinCC flexible, system course 2

✔

✔

✔

✔

3 days

ST-WCCFSY2

SIMATIC WinCC, system course

✔

✔

✔

✔

5 days

ST-BWINCCS

SIMATIC WinCC, advanced configuration, options for networking and
access to database

✔

✔

5 days

ST-BWINOND

ANSI-C in the SIMATIC World, Introduction

✔

✔

5 days

ST-SIMACE

SIMATIC TIA Portal WinCC SCADA retraining course

TIA

SIMATIC TIA Portal WinCC on the machine level

TIA

SIMATIC TIA Portal WinCC SCADA

TIA

SIMATIC TIA Portal WinCC on the machine level

TIA

■ SIMATIC WinCC flexible

■ SIMATIC WinCC V7.x
✔

✔

✔

7

■ SIMATIC WinCC V7.x Market-specific Solutions
Energy management
Energy management with SIMATIC powerrate for WinCC

✔

✔

✔

✔

✔

3 days

ST-EMPRWCC

Energy management with B.Data

✔

✔

✔

✔

✔

4 days

ST-EMBDATA

TIA These courses are based on the new engineering platform TIA Portal.

Siemens ST 80 / ST PC · 2013

7/3

© Siemens AG 2013

Appendix
Standards and approvals
■ Operating system licenses for SIMATIC PC/PG
The accompanying operating system license is only valid for
installation on the supplied SIMATIC PC/PG.
Installation can only be performed on these SIMATIC systems in
accordance with Microsoft OEM licensing regulations.

■ Standards UL (U) and CSA (C)
All HMI products comply with the standards UL (U) and CSA (C),
or the approval procedure has been applied for.
Products which have no approval are specially marked
(see ordering data of the products).

■ CE marking
The electronic products described in this catalog comply with
the requirements and protection objectives of the following
EC directives insofar as they relate to the product concerned.
They also comply with the corresponding harmonized European
standards (EN) published for these products in the Official
Journals of the European Community.
• Directive 2004/108/EC of the European Parliament and
Council on the approximation of the laws of the Member States
relating to electromagnetic compatibility (EMC Directive)
• Directive 2006/95/EC of the European Parliament and of the
Council on the harmonization of the laws of Member States
relating to electrical equipment designed for use within certain
voltage limits (Low Voltage Directive)
• Directive 94/9/EC of the European Parliament and the Council
on approximation of the laws of the Member States concerning equipment and protective systems intended for use in
potentially explosive atmospheres (ATEX Directive).
• Directive 1999/5/EC of the European Parliament and of the
Council on radio equipment and telecommunications terminal
equipment and the mutual recognition of their conformity
(RTTE Directive)
The originals of the declarations of conformity are kept available
for the responsible supervisory authorities at:
SIMATIC HMI:
Siemens AG
I IA AS S ID
Postfach 48 48
90327 Nürnberg
Germany
SIMATIC, SIMATIC NET, SIMATIC PC:
Siemens AG
IA AS EWA
Postfach 19 63
92209 Amberg
Germany
Note on the EMC Directive:
The installation instructions in the manuals must be adhered to
when installing and operating the products described in this catalog. These contain, for example, important information on installation in cabinets and on the use of shielded cables.

7

7/4

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Appendix
Partners at Industry Automation and Drive Technologies
Siemens contacts worldwide

■ Overview
At Siemens Industry Automation and Drive Technologies, more
than 85 000 people are resolutely pursuing the same goal: longterm improvement of your competitive ability. We are committed
to this goal. Thanks to our commitment, we continue to set new
standards in automation and drive technology. In all industries –
worldwide.
At your service locally, around the globe for consulting, sales,
training, service, support, spare parts ... on the entire Industry
Automation and Drive Technologies range.
Your personal contact can be found in our Contacts Database at:
www.siemens.com/automation/partner
You start by selecting a
• Product group,
• Country,
• City,
• Service.

7

Siemens ST 80 / ST PC · 2013

7/5

© Siemens AG 2013

Appendix
Partners at Industry Automation and Drive Technologies
WinCC Competence Centers

■ WinCC Competence Centers
The WinCC Competence Centers are Siemens-internal partners.
They offer a wide range of products and services designed to
make optimal economic and system-oriented use of the openness and integration capability of WinCC.
In addition to the development of standard solutions/add-on
products, they are authorized to implement customized/
industry-specific solutions in the areas of application development and system integration on the basis of WinCC. The portfolio
is rounded off with consulting services, project-related training,
and workshops for decision-makers and users.
Sector competence in addition to automation expertise and
WinCC system know-how ensure professional and efficient solutions. The software is, of course, developed in compliance with
recognized standards on the basis of certified quality management in accordance with DIN ISO 9001.

7

7/6

Siemens ST 80 / ST PC · 2013

You can find more information on the Internet at:
www.siemens.com/wincc-competence-center

© Siemens AG 2013

Appendix
Partners at Industry Automation and Drive Technologies
Siemens Solution Partner Automation

■ Overview
Siemens Solution Partner Automation

Solution Partner Finder

Solution Partner: Highest quality - guaranteed
The products and systems from Siemens Industry Automation
and Drive Technologies offer the ideal platform for all automation
applications.
Under the name of Siemens Solution Partner Automation,
selected system integrators around the world act as uniformly
qualified solution providers for the Siemens range of products
and services in the fields of automation and drives. Day after
day, they utilize their qualified product and system know-how as
well as their excellent industry expertise to your advantage – for
all requirements.
The partner emblem is the guarantee and indicator of proven
quality. The basis for this are defined quality features that identify
Solution Partners as reliable and competent solution providers:
• Solution quality
Always a good result with tried and tested solutions expertise.
• Expert quality
Certified technical competence ensures maximum efficiency.
• Project quality
With proven project experience straight to the target.
• Portfolio quality
Comprehensive portfolio for state-of-the-art solutions from a
single source.

The Siemens Solution Partner Program helps you to find the
optimum partner for your specific requirements.
Support is provided by the Solution Partner Finder, a comprehensive online platform that showcases the profiles of all our
solution partners. You can convince yourself of the competence
of the respective Solution Partner by means of the references
provided. Various search criteria are available for this purpose.
Once you have located a partner, you are only one small step
away from contacting them.
Find the right partner here for your specific task and convince
yourself of the solution competence provided:
www.siemens.com/automation/partnerfinder
Additional information on the Siemens Solution Partner Program
is available online at:
www.siemens.com/automation/solutionpartner

7

Siemens ST 80 / ST PC · 2013

7/7

© Siemens AG 2013

Appendix
Siemens Automation Cooperates with Education
Applicable practical know-how

■ Comprehensive teaching support for educational institutions
• The new TIA Portal training materials for SIMATIC S7-1200 are
available in English, German, French, Italian, Spanish and
Chinese for download.
www.siemens.com/sce/documents
Trainer packages for hands-on learning

Siemens Automation Cooperates with Education (SCE)
offers a global system for sustained support of technical skills.
SCE supports educational institutions in their teaching assignment in the industrial automation sector and offers added value
in the form of partnerships, technical expertise, and know-how.
As the technological leader, our comprehensive range of
services can support you in the knowledge transfer for
Industry 4.0.
Our services at a glance
• Training curriculums for your lessons
• Trainer packages for hands-on learning
• Courses convey up-to-date, specialist knowledge
• Support for your projects/textbooks
• Complete didactic solutions from our partners
• Personal contact for individual support
Training curriculums for your lessons

7

Use our profound industrial know-how for practice-oriented
and individual design of your course. We offer you more than
100 didactically prepared training curriculums on the topics of
automation and drives technology free of charge. These
materials are perfectly matched to your curricula and syllabuses, and optimally suited for use with our trainer packages.
This takes into account all aspects of a modern industrial
solution: installation, configuration, programming, and commissioning. All documents, including projects, can be individually
matched to your specific requirements.
Particular highlights:
• With the new SIMATIC PCS 7 curriculums and trainer
packages, you can pass on basic, practice-oriented PCS 7
knowledge at universities within about 60 hours
(= 1 semester), using plant simulation.

7/8

Siemens ST 80 / ST PC · 2013

Our SCE trainer packages offer a specific combination of
original industrial components which are perfectly matched to
your requirements and can be conveniently used in your course.
These price reduced bundles available exclusively to schools
include innovative and flexible hardware and software
packages. SCE can currently offers more than 90 SCE trainer
packages including related equipment. These cover both the
factory and process automation sectors. You can use them to
impart the complete course contents on industrial automation at
a very low cost.
Trainer packages are available for:
• Introduction to automation technology with LOGO! logic
module and SIMATIC S7-1200 compact controller
• PLC engineering with SIMATIC S7 hardware and STEP 7
software (S7-300, S7-1500 and TIA Portal)
• Operator control and monitoring with SIMATIC HMI
• Industrial networking over bus systems with SIMATIC NET
(PROFINET, PROFIBUS, IO-Link)
• Sensor systems with VISION, RFID and SIWAREX
• Process automation with SIMATIC PCS 7
• Power Monitoring Devices SENTRON PAC 4200
• Motor Management SIMOCODE
• Networked drive and motion technologies with SINAMICS/
SIMOTION
• CNC programming with SinuTrain
Important ordering notes:
Only the following institutions are authorized to obtain trainer
packages: vocational schools, Colleges and Universities,
in-house vocational training departments, non commercial
research institutions and non commercial training departments.
To purchase a trainer package, you require a specific end-use
certificate, which you can obtain from your regional sales office.
www.siemens.com/sce/tp

© Siemens AG 2013

Appendix
Siemens Automation Cooperates with Education
Applicable practical know-how

■ Comprehensive teaching support for educational institutions (continued)
Courses convey up-to-date specialist knowledge

We can provide you with consulting for selected projects and
support from your personal SCE contact as well as our web
based and regional Customer Support.
As a particular service, SCE supports technical authors with our
know-how as well as with intensive technical consulting.
Siemens library of special textbooks covering the industrial
automation sector provides an additional resource for you and
your students. These can be found at the SCE web site.
www.siemens.com/sce/contact
www.siemens.com/sce/books
Complete didactic solutions

Profit from our excellent know-how as the leader in industrial
technologies. We offer you specific courses for automation and
drive technology worldwide. These support you in the practiceoriented transferring of product and system know-how, are in
conformance with curriculums, and derived from the training
fields. Compact technical courses especially for use at universities are also available.
Our range of courses comprises a wide variety of training
modules based on the principle of Totally Integrated Automation
(TIA). The focus is on the same subject areas as with the SCE
trainer packages.
Every PLC and drive course is oriented on state-of-the-art
technology. Your graduates can thus be prepared optimally for
their future professional life.
In some countries we are offering classes based on our training
curriculums. Please inquire with your SCE contact partner.
www.siemens.com/sce/contact
Support for your projects/textbooks

Our partners for learning systems offer a wide range of training
systems and solutions for use in your courses or laboratory.
These models have been designed based on our trainer
packages and thus save you the time and cost of selfconstruction of individual components. The Partner systems
provide you with simple and effective help in the fulfillment of
your teaching assignment.
www.siemens.com/sce/partner
Contact for individual support
You can find your personal SCE contact on our Internet site. Your
local SCE Promoter will answer all your questions concerning the
complete SCE offering, and provide you with timely and
competent information about innovations. When you encounter
challenges, you can profit from our global team of excellence.
If a direct SCE contact is not listed for your country, please
contact your local Siemens office.
www.siemens.com/sce/contact
SCE Support Finder for your Internet request
You are an educator and need support on the topic of industry
automation? Send us your request:
www.siemens.com/sce/supportfinder

Automation and drive technology is characterized by continuous
and rapid developments. Service and Support therefore play an
important role.

6FDQWKH45
FRGHIRUIXUWKHU
LQIRUPDWLRQ
6&(KRPHSDJH

Siemens ST 80 / ST PC · 2013

7/9

7

© Siemens AG 2013

Appendix
Online Services
Information and Ordering
in the Internet and on DVD

■ Siemens Industry Automation and Drive Technologies in the WWW
A detailed knowledge of the range of products and services
available is essential when planning and configuring automation
systems. It goes without saying that this information must always
be fully up-to-date.
Siemens Industry Automation and Drive Technologies has
therefore built up a comprehensive range of information in the
World Wide Web, which offers quick and easy access to all data
required.
Under the address
www.siemens.com/industry
you will find everything you need to know about products, systems and services.

■ Product Selection Using the Interactive Catalog CA 01 of Industry
Detailed information together with convenient interactive
functions:
The interactive catalog CA 01 covers more than 80 000 products
and thus provides a full summary of the Siemens Industry Automation and Drive Technologies product base.
Here you will find everything that you need to solve tasks in the
fields of automation, switchgear, installation and drives.
All information is linked into a user interface which is easy to
work with and intuitive.
After selecting the product of your choice you can order at the
press of a button, by fax or by online link.
Information on the interactive catalog CA 01 can be found in the
Internet under
www.siemens.com/automation/ca01
or on DVD.

■ Easy Shopping with the Industry Mall
The Industry Mall is the virtual department store of Siemens AG
on the Internet. Here you have access to a huge range of products presented in electronic catalogs in an informative and attractive way.
Data transfer via EDIFACT allows the whole procedure from
selection through ordering to tracking of the order to be carried
out online via the Internet.

7

Numerous functions are available to support you.
For example, powerful search functions make it easy to find the
required products, which can be immediately checked for availability. Customer-specific discounts and preparation of quotes
can be carried out online as well as order tracking and tracing.
Please visit the Industry Mall on the Internet under:
www.siemens.com/industrymall

7/10

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Appendix
Online Services
Information and Download Center
Social Media, Mobile Media

■ Downloading Catalogs
In addition to numerous other useful documents, you can also
find the catalogs listed on the back inside cover of this catalog
in the Information and Download Center. Without having to register, you can download these catalogs in PDF format or increasingly as digital page-turning e-books.
The filter dialog box above the first catalog displayed makes it
possible to carry out targeted searches. If you enter “MD 3” for
example, you will find both the MD 30.1 and MD 31.1 catalogs.
If you enter “ST 70” both the ST 70 catalog and the associated
news or add-ons are displayed.
Visit us on the web at:
www.siemens.com/industry/infocenter

■ Social Media
Connect with Siemens through social media: visit our social networking sites for a wealth of useful information, demos on products and services, the opportunity to provide feedback, to exchange information and ideas with customers and other
Siemens employees, and much, much more. Stay in the know
and follow us on the ever-expanding global network of social
media.
Connect with Siemens Industry at our central access point:
www.siemens.com/industry/socialmedia
Or via our product pages at:
www.siemens.com/automation
or
www.siemens.com/drives
To find out more about Siemens' current social media activities
visit us at:
www.siemens.com/socialmedia

■ Mobile Media
Discover the world of Siemens.
We are also constantly expanding our offering of cross-platform
apps for smartphones and tablets. You will find the current Siemens apps at the app store (iOS) or at Google Play (Android).
The Siemens app, for example, tells you all about the history, latest developments and future plans of the company – with informative pictures, fascinating reports and the most recent press
releases.

Siemens ST 80 / ST PC · 2013

7/11

7

© Siemens AG 2013

Appendix
Industry Services
Your machines and plant can do more
– with Industry Services.
Whether it is production or process industry - in view of rising
cost pressure, growing energy costs, and increasingly stringent
environmental regulations, services for industry are a crucial
competitive factor in manufacturing as well as in process industries.
All over the world Siemens supports its customers with product,
system, and application-related services throughout the entire
life cycle of a plant. Right from the earliest stages of planning,
engineering, and building, all the way to operation and modernization. These services enable customers to benefit from the
Siemens experts’ unique technological and product knowledge
and industry expertise.
Thus downtimes are reduced and the utilization of resources is
optimized. The bottom line: increased plant productivity, flexibility, and efficiency, plus reduced overall costs.
Discover all advantages of our service portfolio:
www.siemens.com/industry-services

{ŒŠ•Šˆ“Gj–•šœ“›•ŽGMGG
l•Ž•ŒŒ™•ŽGzœ——–™›
l•Œ™Ž GMG G
l•™–•”Œ•›ˆ“GzŒ™ŠŒš

{ŒŠ•Šˆ“Gj–•šœ“›•ŽGMGG
l•Ž•ŒŒ™•ŽGzœ——–™›
l•Œ™Ž GMG
l•™–•”Œ•›ˆ“GzŒ™ŠŒš

Modernization
Modernization

t–‹Œ™•¡ˆ›–•GM G
v—›”¡ˆ›–•GzŒ™ŠŒš

Planning
Planning

Online Support
Technical Support
Spare Parts
Repair Services
Field Services
Training

Operation
Operation

{ŒŠ•Šˆ“Gj–•šœ“›•ŽGMGG
l•Ž•ŒŒ™•ŽGzœ——–™›

Engineer
Engineer
&
& Build
Build

l•Œ™Ž GMG
l•™–•”Œ•›ˆ“GzŒ™ŠŒš

w“ˆ•›Gtˆ•›Œ•ˆ•ŠŒGMGG
j–•‹›–•Gt–•›–™•Ž
zŒ™ŠŒG
l•Œ™Ž GMGl•™–•”Œ•›ˆ“G
t–‹Œ™•¡ˆ›–•GMGv—›”¡ˆ›–•GzŒ™ŠŒš

7
G_DA65_EN_00270

Siemens supports its clients with technology based Services across a plants entire life cycle.

7/12

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Appendix
Industry Services
Industry Services
for the entire life cycle
Online Support
Online support is a comprehensive information system for all
questions relating to products, systems, and solutions that
Siemens has developed for industry over time. With more than
300,000 documents, examples and tools, it offers users of automation and drive technology a way to quickly find up-to-date information. The 24-hour service enables direct, central access to
detailed product information as well as numerous solution examples for programming, configuration and application.
The content, in six languages, is increasingly multimediabased
– and now also available as a mobile app. Online support’s
“Technical Forum” offers users the opportunity to share information with each other. The “Support Request” option can be used
to contact Siemens’ technical support experts. The latest content, software updates, and news via newsletters and Twitter ensure that industry users are always up to date.

www.siemens.com/industry/onlinesupport

Online Support App

Using the Online Support app, you can access over 300,000
documents covering all Siemens industrial products - anywhere,
any time. Regardless of whether you need help implementing
your project, fault-finding, expanding your system or are planning a new machine.
You have access to FAQs, manuals, certificates, characteristics
curves, application examples, product notices (e.g. announcements of new products) and information on successor products
in the event that a product is discontinued.
Just scan the product code printed on the product directly using
the camera of your mobile device to immediately see all technical information available on this product at a glance. The graphical CAx information (3D model, circuit diagrams or EPLAN macros) is also displayed. You can forward this information to your
workplace using the e-mail function.

find your favorite pages – articles you need frequently – under
“mySupport”. You also receive selected news on new functions,
important articles or events in the News section.

Scan the QR code
for information on
our Online Support
app.

The app is available free of charge from the Apple App Store
(iOS) or from Google Play (Android).
www.siemens.com/industry/onlinesupportapp

The search function retrieves product information and articles
and supports you with a personalized suggestion list. You can

Technical Support
The ability to quickly analyze system and error messages and
take appropriate action are key factors in ensuring that plants
run safely and efficiently. Questions can arise at any time and in
any industry, whether it’s an individual product or a complete automation solution. Siemens technical support offers individual
technical assistance in matters related to functionality, how to
operate, applications, and fault clearance in industrial products
and systems – at any time and globally, over the phone, by email, or via remote access. Experienced experts from Siemens
answer incoming questions promptly. Depending on the requirements, they first consult specialists in the areas of development,
on-site services, and sales. Technical support is also available
for discontinued products that are no longer available. Using the
support request number, any inquiry can be clearly identified
and systematically tracked.

7

Siemens ST 80 / ST PC · 2013

7/13

© Siemens AG 2013

Appendix
Industry Services
Industry Services
for the entire life cycle
Spare Parts
Drive and automation systems must be available at all times.
Even a single missing spare part can bring the entire plant to a
standstill – and result in substantial financial losses for the operator. The spare parts services from Siemens protects against
such losses – with the aid of quickly available, original spare
parts that ensure smooth interaction with all other system components. Spare parts are kept on hand for up to ten years; defective parts can be returned. For many products and solutions,
individual spare parts packages ensure a preventive stock of
spare parts on-site. The spare parts services is available around
the world and around the clock. Optimum supply chain logistics
ensure that replacement components reach their destination as
quickly as possible. Siemens’ logistics experts take care of planning and management as well as procurement, transportation,
customs handling, warehousing, and complete order management for spare parts.

Repair Services
Reliable electrical and electronic equipment is crucial for operating continuous processes. That is why it is essential that motors and converters always undergo highly specialized repair
and maintenance. Siemens offers complete customer and repair
services – on site and in repair centers – as well as technical
emergency services worldwide. The repair services include all
measures necessary to quickly restore the functionality of defective units. In addition, services such as spare parts logistics,
spare parts storage and rapid manufacturing are available to
plant operators in all verticals. With a global network of certified
repair shops operated by Siemens as well as third parties, Siemens handles the maintenance and overhaul of motors, converters, and other devices as an authorized service partner.

Field Services
It’s a top priority in all industries: the availability of plants and
equipment. Siemens offers specialized maintenance services
such as inspection and upkeep as well as rapid fault clearance
in industrial plants – worldwide, continuously, and even with
emergency services as needed. The services include startup as
well as maintenance and fault clearance during operation. The
startup service includes checking the installation, function tests,
parameterization, integration tests for machines and plants, trial
operation, final acceptance, and employee training. All services,
including remote maintenance of drives, are also available as elements of customized service contracts.

7

7/14

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Appendix
Industry Services
Industry Services
for the entire life cycle
Training
Increasingly, up-to-date knowledge is becoming a determining
factor in success. One of the key resources of any company is
well-trained staff that can make the right decision at the right moment and take full advantage of the potential. With SITRAIN –
Training for Industry, Siemens offers comprehensive advanced
training programs. The technical training courses convey expertise and practical knowledge directly from the manufacturer.
SITRAIN covers Siemens’ entire product and system portfolio in
the field of automation and drives. Together with the customer,
Siemens determines the company’s individual training needs
and then develops an advanced training program tailored to the
desired requirements. Additional services guarantee that the
knowledge of all Siemens partners and their employees is always up-to-date.

Technical Consulting & Engineering Support
The efficiency of plants and processes leads to sustainable economic success. Individual services from Siemens help save substantial time and money while also guaranteeing maximum
safety. Technical consulting covers the selection of products and
systems for efficient industrial plants. The services include planning, consulting, and conceptual design as well as product
training, application support, and configuration verification – in
all phases of a plant’s lifecycle and in all questions related to
product safety. Engineering support offers competent assistance throughout the entire project, from developing a precise
structure for startup to product-specific preparation for implementation as well as support services in areas such as prototype
development, testing and acceptance.

Energy & Environmental Services
Efficient energy use and resource conservation – these top sustainability concerns pay off – both for the environment and for
companies. Siemens offers integrated solutions that unlock all
technical and organizational potential for successful environmental management. Customized consulting services are aimed
at sustainably lowering the cost of energy and environmental
protection and thus increasing plant efficiency and availability.
The experts provide support in the conceptual design and implementation of systematic solutions in energy and environmental management, enabling maximum energy efficiency and optimized water consumption throughout the entire company.
Improved data transparency makes it possible to identify savings potential, reduce emissions, optimize production processes, and thereby noticeably cut costs.

7

Siemens ST 80 / ST PC · 2013

7/15

© Siemens AG 2013

Appendix
Industry Services
Industry Services
for the entire life cycle
Modernization & Optimization Services
High machine availability, expanded functionality and selective
energy savings – in all industries, these are decisive factors for
increasing productivity and lowering costs. Whether a company
wants to modernize individual machines, optimize drive systems, or upgrade entire plants, Siemens’ experts support the
projects from planning to commissioning.
Expert consulting and project management with solution responsibility lead to security and make it possible to specifically identify savings potential in production. This secures investments
over the long term and increases economic efficiency in operation.

Plant Maintenance & Condition Monitoring
Modern industrial plants are complex and highly automated.
They must operate efficiently in order to ensure the company’s
competitive strength. In addition, the steadily increasing networking of machines and plants require consistent security concepts. Maintenance and status monitoring as well as the implementation of integrated security concepts by Siemens’ experts
support optimum plant use and avoid downtime. The services include maintenance management as well as consulting on maintenance concepts, including the complete handling and execution of the necessary measures. Complete solutions also cover
remote services, including analysis, remote diagnosis, and remote monitoring. These are based on the Siemens Remote Services platform with certified IT security.

Service Contracts

7

Making maintenance costs calculable, reducing interfaces,
speeding up response times, and unburdening the company’s
resources – the reduced downtimes that these measures
achieve increase the productivity of a plant. Service contracts
from Siemens make maintenance and repairs more cost-effective and efficient. The service packages include local and remote maintenance for a system or product group in automation
and drive technology. Whether you need extended service periods, defined response times, or special maintenance intervals,
the services are compiled individually and according to need.
They can be adjusted flexibly at any time and used independently of each other. The expertise of Siemens’ specialists and
the capabilities of remote maintenance thus ensure reliable and
fast maintenance processes throughout a plant’s entire lifecycle.

7/16

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Appendix
Siemens Service Option for SIMATIC PC / PG
■ Siemens Service Option for SIMATIC PC / PG
Product family

Order No.
Service Option

Order designation

SIMATIC Rack PC

A5E00510072

36 months service
option for SIMATIC
Rack PC and Box PC

A5E00509961

36 months service
option for SIMATIC
Panel PCs

A5E00510007

36 months service
option for SIMATIC
Field PG M2/M3

• SIMATIC IPC547
• SIMATIC IPC647
• SIMATIC IPC847
SIMATIC Box PC
• SIMATIC IPC227
• SIMATIC IPC427
• SIMATIC IPC627
• SIMATIC IPC827

The expanded hardware service for SIMATIC PC/PG
products

SIMATIC Panel PC

Purchasing and registering this additional agreement for a
SIMATIC PC/PG extends the time period for free repairs of this
device to 36 months after delivery.

• SIMATIC IPC477D/
HMI IPC477

Scope of services of the service option within the period of
service (36 months):
• Free1) repair during the period of service at one of our
authorized repair centers near you
The addresses of our worldwide partners can be found on the
Internet at www.siemens.com/asis
• Within the agreed contractual period, Siemens will bear the
costs that are incurred in the repair center (labor and
materials/replacement parts), which are needed to restore the
functions2) of the hardware
• Siemens will also assume the return shipping costs of the
repaired device from the repair center to the customer

• SIMATIC HMI IPC677

1)

Wear and tear as well as problems that arise due to improper handling of
the devices are not included.

2)

For hard disk defects that require the system to be restored, the repair
service will only cover restoring the installation to its original condition
ex works.
The uploading of additional application software, drivers and setting up the
operating software are not covered by the free repair service.

• SIMATIC IPC277

• SIMATIC HMI IPC577
SIMATIC Field PG
• SIMATIC Field PG M2
• SIMATIC Field PG M3

Ordering and registering the additional agreement:
• Select the appropriate order number for the optional package
based on the family of products and place your order
• Scope of delivery:
Description of services in 4 languages + service device label
with a license number for identifying the additional agreement
on the device
• Activation of the service license number for a SIMATIC PC/
SIMATIC PG via the Internet (www.siemens.com/ped):
The registration must be completed within the first 90 days
after initial delivery of the device!

7

Siemens ST 80 / ST PC · 2013

7/17

© Siemens AG 2013

Appendix
Expertise and services relating to all aspects of PC-based Automation
■ Overview
Expertise and services relating to all aspects
of PC-based Automation
Do you require support with the dimensioning and options of a
PC-based Automation project, or even engineering support?
Specifically for this purpose, Siemens has established a team of
specialists in Cologne and Milan who work closely with Development and Product Marketing and can thus provide our sales
departments worldwide with competent support in PC-based
Automation.

■ Our core competencies
• Design of PC-based Automation systems from Siemens
• Integrated, customer-specific technology (add-ons) using
high-level languages (C++) in Windows or real-time environments
• Knowledge transfer/workshops for the integration of thirdparty components, as well as for applications using the Open
Development Kit (ODK)
• Technology and application know-how
• Development of add-ons for WinAC and WinCC flexible

■ Reference applications
• Fast recording of measured values
• Software blocks for drives library
• Customer-specific communications via Ethernet
(OPC/ActiveX, TCP socket)
• Synchronous operation, flying shear, table interpolation for
electric and hydraulic axes
• Integration of PCI cards into PC-based Automation applications (e.g. WinAC and ASi-Bus)
• Customer-specific development and integration of C++
programs
• Database connections
• Integration of complex control algorithms

7

■ Contacts
Activation of the Competence Centers for your application via
your regional contact.
If you do not yet have a contact person in your region, just go to:
www.siemens.com/automation/partner

7/18

Siemens ST 80 / ST PC · 2013

The latest information about the workshops offered can be found
on the Internet:
www.siemens.com/pc-based

© Siemens AG 2013

Appendix
Software Licenses

■ Overview
Software types
Software requiring a license is categorized into types.
The following software types have been defined:
• Engineering software
• Runtime software
Engineering software
This includes all software products for creating (engineering)
user software, e.g. for configuring, programming, parameterizing, testing, commissioning or servicing.
Data generated with engineering software and executable
programs can be duplicated for your own use or for use by thirdparties free-of-charge.
Runtime software
This includes all software products required for plant/machine
operation, e.g. operating system, basic system, system expansions, drivers, etc.
The duplication of the runtime software and executable programs created with the runtime software for your own use or for
use by third-parties is subject to a charge.
You can find information about license fees according to use in
the ordering data (e.g. in the catalog). Examples of categories of
use include per CPU, per installation, per channel, per instance,
per axis, per control loop, per variable, etc.
Information about extended rights of use for parameterization/configuration tools supplied as integral components of the
scope of delivery can be found in the readme file supplied with
the relevant product(s).
License types
Siemens Industry Automation & Drive Technologies offers various types of software license:
• Floating license
• Single license
• Rental license
• Rental floating license
• Trial license
• Demo license
• Demo floating license
Floating license
The software may be installed for internal use on any number of
devices by the licensee. Only the concurrent user is licensed.
The concurrent user is the person using the program. Use
begins when the software is started.
A license is required for each concurrent user.
Single license
Unlike the floating license, a single license permits only one
installation of the software per license.
The type of use licensed is specified in the ordering data and
in the Certificate of License (CoL). Types of use include for
example per instance, per axis, per channel, etc.
One single license is required for each type of use defined.
Rental license
A rental license supports the "sporadic use" of engineering
software. Once the license key has been installed, the software
can be used for a specific period of time (the operating hours do
not have to be consecutive).
One license is required for each installation of the software.

Rental floating license
The rental floating license corresponds to the rental license,
except that a license is not required for each installation of the
software. Rather, one license is required per object (for example,
user or device).
Trial license
A trial license supports "short-term use" of the software in a nonproductive context, e.g. for testing and evaluation purposes.
It can be transferred to another license.
Demo license
The demo license support the "sporadic use" of engineering software in a non-productive context, for example, use for testing
and evaluation purposes. It can be transferred to another
license. After the installation of the license key, the software can
be operated for a specific period of time, whereby usage can be
interrupted as often as required.
One license is required per installation of the software.
Demo floating license
The demo floating license corresponds to the demo license,
except that a license is not required for each installation of the
software. Rather, one license is required per object (for example,
user or device).
Certificate of license (CoL)
The CoL is the licensee's proof that the use of the software has
been licensed by Siemens. A CoL is required for every type of
use and must be kept in a safe place.
Downgrading
The licensee is permitted to use the software or an earlier version/release of the software, provided that the licensee owns
such a version/release and its use is technically feasible.
Delivery versions
Software is constantly being updated.
The following delivery versions
• PowerPack
• Upgrade
can be used to access updates.
Existing bug fixes are supplied with the ServicePack version.
PowerPack
PowerPacks can be used to upgrade to more powerful software.
The licensee receives a new license agreement and CoL
(Certificate of License) with the PowerPack. This CoL, together
with the CoL for the original product, proves that the new software is licensed.
A separate PowerPack must be purchased for each original
license of the software to be replaced.
Upgrade
An upgrade permits the use of a new version of the software on
the condition that a license for a previous version of the product
is already held.
The licensee receives a new license agreement and CoL with
the upgrade. This CoL, together with the CoL for the previous
product, proves that the new version is licensed.
A separate upgrade must be purchased for each original license
of the software to be upgraded.

Siemens ST 80 / ST PC · 2013

7/19

7

© Siemens AG 2013

Appendix
Software Licenses

■ Overview
ServicePack
ServicePacks are used to debug existing products.
ServicePacks may be duplicated for use as prescribed according to the number of existing original licenses.
License key
Siemens Industry Automation & Drive Technologies supplies
software products with and without license keys.
The license key serves as an electronic license stamp and
is also the "switch" for activating the software (floating license,
rental license, etc.).
The complete installation of software products requiring license
keys includes the program to be licensed (the software) and the
license key (which represents the license).

7

7/20

Siemens ST 80 / ST PC · 2013

Software Update Service (SUS)
As part of the SUS contract, all software updates for the respective product are made available to you free of charge for a period
of one year from the invoice date. The contract will automatically
be extended for one year if it is not canceled three months
before it expires.
The possession of the current version of the respective software
is a basic condition for entering into an SUS contract.
You can download explanations concerning license conditions from
www.siemens.com/automation/salesmaterial-as/catalog/en/
terms_of_trade_en.pdf

© Siemens AG 2013

Appendix
Index
Numerics
19" slide-in keyboard PS/2 with trackball .........................
1-phase, 24 V DC/10 A (SITOP PSU100S).......................
1-phase, 24 V DC/20 A (SITOP PSU100S).......................
24 V DC uninterruptible power supplies ..........................
3-phase, 24 V DC/10 A (SITOP PSU300S).......................
3-phase, 24 V DC/20 A (SITOP PSU300S).......................
3-phase, 24 V DC/40 A (SITOP PSU300S).......................

C (continued)
5/169
5/171
5/171
5/174
5/172
5/172
5/173

A
A whole world of operator control and monitoring ............... 1/6
Accessories for fully enclosed HMI devices ...................... 3/16
Adapter sets ....................................................................... 3/16
Additional accessories ..................................................... 2/101
Applicable practical know-how ............................................ 7/8
Automotive industry............................................................ 6/30
B
Basic Panels....................................................................... 2/12
Basic Panels – Standard .................................................... 2/12
Batteries ........................................................................... 2/137
Battery module 1.2 Ah...................................................... 5/182
Battery module 2.5 Ah...................................................... 5/183
Battery module 3.2 Ah...................................................... 5/183
Battery module 7 Ah......................................................... 5/184
Battery module 12 Ah....................................................... 5/184
Box PC................................................................................ 5/27
BSP SIMATIC IPC V4.0 for RMOS3 .................................. 5/152
C
Catalog improvement suggestions .................................... 7/28
Charging station ................................................................. 2/74
Comfort Panels................................................................... 2/26
Comfort Panels – Standard ................................................ 2/26
Communication – Industrial Ethernet ............................... 5/186
Communication – PROFIBUS ........................................... 5/208
Conditions of sale and delivery .......................................... 7/32
Connecting cables ........................................................... 2/112
Connection options to SIMATIC IPCs ............................... 5/186
Connection options to SIMATIC PCs ................................ 5/208
Connectors/converters/adapters ..................................... 2/104
Controllers from other manufacturers................................. 2/79
Course overview................................................................... 7/3

CP 1604............................................................................ 5/187
CP 1612 A2 ...................................................................... 5/189
CP 1613 A2 ...................................................................... 5/191
CP 1616............................................................................ 5/188
CP 1623............................................................................ 5/192
CP 1628............................................................................ 5/193
CP 5512............................................................................ 5/219
CP 5603............................................................................ 5/209
CP 5612............................................................................ 5/221
CP 5613 A2 ...................................................................... 5/211
CP 5614 A2 ...................................................................... 5/213
CP 5622............................................................................ 5/223
CP 5623............................................................................ 5/215
CP 5624............................................................................ 5/217
CP 5711............................................................................ 5/225
Customized adaptations ...................................................... 6/4
Customized Automation ....................................................... 6/2
Customized hardware .......................................................... 6/6
Customized software.......................................................... 6/20
D
DC UPS module 6 A ......................................................... 5/181
DC UPS module 15 A ....................................................... 5/181
DC UPS module 40 A ....................................................... 5/182
DC UPS with battery modules .......................................... 5/179
DC UPS with capacitors ................................................... 5/176
Design products................................................................... 6/7
Devices with stainless steel front ....................................... 3/21
E
EC31................................................................................... 5/93
Embedded bundles/Software packages.......................... 5/101
Embedded Controller ......................................................... 5/91
Examples of sector products ............................................. 6/26
Expansion components and accessories ........................ 5/153
Expansion modules .......................................................... 5/100
Expertise and services relating to
all aspects of PC-based Automation.................................. 7/18
Extension units ................................................................... 3/17

7

Siemens ST 80 / ST PC · 2013

7/21

© Siemens AG 2013

Appendix
Index
F

M

Fasteners.......................................................................... 2/130
Fax form ............................................................................. 7/28
Flat Panels with stainless steel front................................... 6/46
Flat Panels, 10.4" for Panel PC ........................................... 6/38
Flexible front design concept for HMI products................. 6/11
Food and beverages industry/pharmaceuticals ................ 6/39
Front panel 15" Touch and Key for Panel PCs,
resistant to honing oil ......................................................... 6/36
Front panel with motion keys at side .................................. 6/32
Fully enclosed HMI devices ................................................. 3/3

MASTERGUARD power supply........................................ 5/185
Memory media ................................................................. 2/116
Mobile Panel 277 10" Remote Operate .............................. 6/33
Mobile panel accessories .................................................. 2/99
Mobile Panels ..................................................................... 2/44
Mobile Panels – 170 series................................................. 2/45
Mobile Panels – 270 series................................................. 2/52
MP 277 8" Touch control console ....................................... 6/13
MP 377 15" Touch daylight readable.................................. 6/50
O

G
Gain transparency and lower costs ..................................... 1/2
General HMI accessories................................................... 2/96
General machine construction ........................................... 6/36
H
HARDNET-IE S7-REDCONNECT...................................... 5/194
HMI connecting components ........................................... 2/105
HMI devices for hazardous areas ...................................... 3/25
HMI operator stations for the automobile industry ............. 6/30
HMI operator stations for turnkey products........................ 6/18
HMI Panels as rear-mounted devices ................................ 6/44
HMI software ........................................................................ 4/2
HMI Software in the TIA portal.............................................. 4/5
HMI stainless steel operator stations ................................. 6/48
I
IE FC RJ45 Plug 2 x 2....................................................... 2/110
Industrial monitors and thin clients................................... 5/117
Industrial PC ......................................................................... 5/2
Industrial USB Hub 4.......................................................... 2/97
Industry Services................................................................ 7/12
Industry Services
for the entire life cycle ........................................................ 7/13
Information and Download Center ..................................... 7/11
Information and Ordering
in the Internet and on DVD ................................................. 7/10
Input and output devices ................................................. 5/167
IP65 keyboards .................................................................. 3/19
IP65 membrane keyboard, desk version ......................... 5/168
K
Key Panels............................................................................ 2/6
L

7

Labeling strips.................................................................. 2/135
Length key for connecting cables...................................... 7/27

7/22

Siemens ST 80 / ST PC · 2013

OEM products .................................................................... 6/10
Oil & gas/chemicals/shipbuilding....................................... 6/49
Online Services .................................................................. 7/10
OPC server for Industrial Ethernet ................................... 5/201
OPC server for PROFIBUS ............................................... 5/229
Order No. Index.................................................................. 7/25
P
Panel PC............................................................................. 5/50
Panels and Panel PCs with stainless steel front................. 6/41
Partners at Industry Automation and Drive Technologies .... 7/5
PC I/O ............................................................................... 5/156
PLCs from other manufacturers ......................................... 2/90
PN CBA OPC server......................................................... 5/203
Power supply unit ............................................................. 2/100
Protective covers.............................................................. 2/122
Protective films ................................................................. 2/124
R
Rack PC................................................................................ 5/3
Remote Operate Software .................................................. 6/21
Renewable energy ............................................................. 6/27
RMOS3 real-time operating system ................................. 5/146
RMOS3 V3.50 real-time operating system ....................... 5/147
RMOS3-GNU V3.0............................................................ 5/149
RMOS3-GRAPHX V1.0 ..................................................... 5/151
RMOS3-TCP/IP V3.0......................................................... 5/150
RS485 bus connector....................................................... 2/109

© Siemens AG 2013

Appendix
Index
S

S (continued)

S7 OPC Redundancy for Industrial Ethernet.................... 5/205
S7 OPC Redundancy for PROFIBUS ............................... 5/230
S7 OpenModbusTCP ......................................................... 6/24
SCADA System SIMATIC WinCC ....................................... 4/88
SCADA System SIMATIC WinCC Open Architecture ....... 4/146
SCD desk monitors SCD 19101 ....................................... 5/134
SCD monitors 1900 .......................................................... 5/136
Service sets ...................................................................... 2/118
Siemens Automation Cooperates with Education ................ 7/8
Siemens contacts worldwide................................................ 7/5
Siemens Industry Training .................................................... 7/2
Siemens Service Option for SIMATIC PC / PG ................... 7/17
Siemens Solution Partner Automation .................................. 7/7
SIMATIC 505....................................................................... 2/89
SIMATIC B.Data.................................................................. 4/52
SIMATIC BATCH for WinCC.............................................. 4/108
SIMATIC Flat Panel PRO .................................................... 3/12
SIMATIC Flat Panels ......................................................... 5/130
SIMATIC HMI accessories.................................................. 2/96
SIMATIC HMI IPC477C....................................................... 5/63
SIMATIC HMI IPC477C bundles....................................... 5/110
SIMATIC HMI IPC477C PRO ................................................ 3/7
SIMATIC HMI IPC577C....................................................... 5/67
SIMATIC HMI IPC677C....................................................... 5/71
SIMATIC HMI IPC677C INOX ............................................. 3/22
SIMATIC HMI KP8/KP8F/32F ................................................ 2/6
SIMATIC HMI Net Panel ..................................................... 6/14
SIMATIC HMI operator control and
monitoring systems .............................................................. 1/2
SIMATIC HMI Panel PC Ex ................................................. 3/26
SIMATIC HMI Thin Client Ex ............................................... 3/30
SIMATIC Industrial Flat Panel ........................................... 5/120
SIMATIC Industrial Flat Panel MT ..................................... 5/117
SIMATIC Industrial PC .......................................................... 5/2
SIMATIC Industrial Thin Client .......................................... 5/139
SIMATIC Information Server ............................................. 4/110
SIMATIC IPC BIOS Manager ............................................ 5/166
SIMATIC IPC CompactFlash ............................................ 5/155
SIMATIC IPC DiagMonitor ................................................ 5/164
SIMATIC IPC Image & Partition Creator ........................... 5/163
SIMATIC IPC Remote Manager ........................................ 5/165
SIMATIC IPC227D .............................................................. 5/30
SIMATIC IPC227D bundles .............................................. 5/102
SIMATIC IPC277D .............................................................. 5/53
SIMATIC IPC277D bundles .............................................. 5/108

SIMATIC IPC427C .............................................................. 5/39
SIMATIC IPC427C bundles .............................................. 5/104
SIMATIC IPC427D .............................................................. 5/36
SIMATIC IPC427D bundles .............................................. 5/103
SIMATIC IPC477D .............................................................. 5/58
SIMATIC IPC477D bundles .............................................. 5/109
SIMATIC IPC547D ................................................................ 5/7
SIMATIC IPC627C .............................................................. 5/44
SIMATIC IPC647C .............................................................. 5/13
SIMATIC IPC827C .............................................................. 5/47
SIMATIC IPC847C .............................................................. 5/20
SIMATIC KNX/EIB2S7......................................................... 6/22
SIMATIC Logon ....................................................... 4/37, 4/111
SIMATIC Logon for WinCC flexible..................................... 4/76
SIMATIC Maintenance Station .......................................... 4/112
SIMATIC Mobile Panel 177 ................................................. 2/45
SIMATIC Mobile Panel 277 ................................................. 2/52
SIMATIC Mobile Panel 277(F) IWLAN ................................ 2/57
SIMATIC mobile panel accessories ................................... 2/99
SIMATIC MP 377 PRO .......................................................... 3/4
SIMATIC Panel PC .............................................................. 5/50
SIMATIC Panel PC Remote Kit ......................................... 5/161
SIMATIC PC keyboard...................................................... 5/167
SIMATIC PC-based Automation ........................................... 1/8
SIMATIC PC-based controllers........................................... 5/76
SIMATIC powerrate ............................................................ 4/56
SIMATIC ProAgent............................................................ 4/161
SIMATIC ProAgent process diagnostics software............ 4/161
SIMATIC Process Historian............................................... 4/115
SIMATIC S5 ........................................................................ 2/87
SIMATIC S7 ............................................................... 2/77, 2/84
SIMATIC Thin Client.......................................................... 5/143
SIMATIC Thin Client PRO ................................................... 3/14
SIMATIC WinAC ODK ......................................................... 5/90
SIMATIC WinAC RTX .......................................................... 5/77
SIMATIC WinAC RTX F ....................................................... 5/84
SIMATIC WinCC ................................................................. 4/88
SIMATIC WinCC (TIA Portal) Engineering ............................ 4/6
SIMATIC WinCC (TIA Portal) options.................................. 4/31
SIMATIC WinCC (TIA Portal) Runtime ................................ 4/12
SIMATIC WinCC flexible ES................................................ 4/60
SIMATIC WinCC flexible HMI system ................................. 4/59
SIMATIC WinCC flexible options ........................................ 4/71
SIMATIC WinCC flexible RT................................................ 4/64
SIMATIC WinCC Open Architecture ................................. 4/146

Siemens ST 80 / ST PC · 2013

7/23

7

© Siemens AG 2013

Appendix
Index
S (continued)

W

SIMATIC WinCC Open Architecture Add-ons .................. 4/155
SIMATIC WinCC options................................................... 4/107
SINEMA server ................................................................. 5/207
SIPLUS Basic Panels.......................................................... 2/24
SIPLUS Comfort Panels...................................................... 2/40
SIPLUS connection boxes.................................................. 2/73
SITOP power supplies...................................................... 5/170
SITOP UPS500P ............................................................... 5/178
SITOP UPS500S ............................................................... 5/177
SNMP OPC server ............................................................ 5/206
Social Media, Mobile Media ............................................... 7/11
SOFTNET for Industrial Ethernet ...................................... 5/196
SOFTNET for PROFIBUS .................................................. 5/227
SOFTNET PN IO ............................................................... 5/199
SOFTNET-IE RNA ............................................................. 5/198
Software for energy management ...................................... 4/51
Software Licenses .............................................................. 7/19
Software packages for SIMATIC IPC and S7-mEC .......... 5/114
Solar systems ..................................................................... 6/28
Standards and approvals ..................................................... 7/4
System components........................................................... 2/69
System components for Mobile Panels .............................. 2/69
System interfaces with WinCC (TIA Portal) ........................ 2/76
System interfaces with WinCC flexible ............................... 2/83

WinCC add-ons and partner management ...................... 4/144
WinCC Audit ....................................................................... 4/36
WinCC Competence Centers ............................................... 7/6
WinCC ControlDevelopment .............................................. 4/50
WinCC DataMonitor............................................................ 4/47
WinCC flexible /Archives .................................................... 4/73
WinCC flexible /Audit.......................................................... 4/75
WinCC flexible /ChangeControl.......................................... 4/72
WinCC flexible /OPC server ............................................... 4/85
WinCC flexible /ProAgent ................................................... 4/87
WinCC flexible /Recipes..................................................... 4/74
WinCC flexible /Sm@rtAccess............................................ 4/78
WinCC flexible /Sm@rtService............................................ 4/82
WinCC Logging .................................................................. 4/34
WinCC Recipes .................................................................. 4/32
WinCC Runtime Advanced................................................. 4/13
WinCC Runtime Communication ........................................ 4/25
WinCC Runtime Professional.............................................. 4/19
WinCC Server / WinCC Client............................................. 4/42
WinCC Sm@rtServer........................................................... 4/38
WinCC WebNavigator ........................................................ 4/44
WinCC/Calendar Scheduler ............................................. 4/116
WinCC/Central Archive Server (CAS)............................... 4/117
WinCC/ChangeControl & WinCC/Audit ............................ 4/118
WinCC/Connectivity Pack &
WinCC/Connectivity Station.............................................. 4/120
WinCC/DataMonitor.......................................................... 4/122
WinCC/DowntimeMonitor ................................................. 4/124
WinCC/Event Notifier ........................................................ 4/126
WinCC/IndustrialDataBridge ............................................ 4/127
WinCC/IndustrialX ............................................................ 4/129
WinCC/Open Development Kit (ODK).............................. 4/130
WinCC/ProAgent .............................................................. 4/131
WinCC/Redundancy......................................................... 4/132
WinCC/Server ................................................................... 4/133
WinCC/TeleControl ........................................................... 4/134
WinCC/User Archives....................................................... 4/138
WinCC/Web Navigator ..................................................... 4/139
Wind farms ......................................................................... 6/29

T
Terminal boxes ...................................................................
Touch pen and touch stylus ...............................................
Transponder .......................................................................
Turnkey products................................................................

2/70
2/98
2/75
6/17

U
USB interfaces ................................................................... 3/20

Y
Your machines and plant can do more
– with Industry Services ..................................................... 7/12

7

7/24

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Appendix
Order No. Index
2XV9

6AV6 (Fortsetzung)

2XV9450 .................................................................. 4/105, 6/25

6AV6645 .............................. 2/51, 2/56, 2/67, 2/98, 2/129, 6/34
6AV6646 ................................................ 3/15, 5/142, 5/144, 6/9
6AV6647 ...................................................................... 2/21, 6/8
6AV6651 .................................................................... 2/21, 2/67
6AV6653 .................................................................. 3/15, 5/144
6AV6671 ............................... 2/51, 2/56, 2/72, 2/73, 2/75, 2/97,
.............................................. 2/100, 2/108, 2/117, 2/121, 2/123,
............................. 2/129, 2/134, 2/136, 2/138, 5/55, 5/144, 6/34
6AV6675 ........................................................................... 2/121
6AV6691 .............................. 2/51, 2/56, 2/67, 4/63, 4/69, 4/165

6AG1
6AG1124
6AG1500
6AG1647
6AG1671
6AG1931
6AG1972

............................................................................ 2/43
.......................................................................... 2/109
............................................................................ 2/25
............................................................................ 2/73
............................................................... 5/181, 5/182
............................................................... 2/109, 5/181

6AG4
6AG4070
6AG4104
6AG4112
6AG4114
6AG4140

............................................................................ 5/42
................................................................... 5/10, 5/11
................................................................... 5/17, 5/18
................................................................... 5/22, 5/23
............................................................................ 5/37

6AR1
6AR1403 .......................................... 5/148, 5/150, 5/150, 5/152
6AR1405 ................................................................ 5/148, 5/149
6AV2
6AV2107 ........................................ 4/18, 4/23, 4/24, 4/33, 4/35,
................................................ 4/36, 4/41, 4/43, 4/46, 4/49, 4/50
6AV2114 ........................................................................... 5/115
6AV2115 ........................................................................... 5/115
6AV2124 ....................................... 2/36, 2/129, 5/55, 5/128, 6/8
6AV2132 ............................................................................. 2/21
6AV2181 ............................................ 2/36, 2/117, 2/121, 2/133
6AV3
6AV3672 ........................................................................... 2/129
6AV3678 ........................................................................... 2/121
6AV3688 ............................................................. 2/10, 3/18, 6/8
6AV6
6AV6351 ................................................................ 4/152, 4/153
6AV6352 ............................... 4/153, 4/154, 4/158, 4/159, 4/160
6AV6361 ................................................................ 4/110, 4/115
6AV6371 .............................. 4/101, 4/102, 4/117, 4/119, 4/121,
.............................................. 4/123, 4/128, 4/129, 4/130, 4/131,
.................................... 4/132, 4/133, 4/138, 4/142, 4/143, 4/165
6AV6372 ................................... 4/55, 4/58, 4/116, 4/125, 4/126
6AV6381 ................................................................ 4/101, 4/102
6AV6382 ........................................................................... 5/115
6AV6574 .................... 2/102, 2/117, 2/121, 2/123, 2/129, 2/136
6AV6610 .................................................................... 4/62, 4/63
6AV6611 .................................................................... 4/62, 4/63
6AV6612 ........................................................... 4/10, 4/62, 4/63
6AV6613 ........................................................... 4/10, 4/62, 4/63
6AV6618 ... 4/69, 4/73, 4/74, 4/75, 4/81, 4/84, 4/86, 4/87, 4/165
6AV6623 ........................................................................... 5/115
6AV6642 ...................................................................... 6/8, 6/43
6AV6643 .................................................... 6/8, 6/23, 6/43, 6/45
6AV6644 ............................................. 3/6, 6/8, 6/43, 6/45, 6/51

6AV7
6AV7200 .................................................................... 3/28, 3/31
6AV7240 .................................................................... 5/60, 5/61
6AV7426 ............................................................................. 6/16
6AV7461 ............................................................................. 6/38
6AV7466 ................................................................ 5/119, 5/137
6AV7476 ............................................................................. 6/47
6AV7486 ............................................................................. 6/47
6AV7671 ............... 5/65, 5/69, 5/74, 5/113, 5/128, 5/132, 5/161
6AV7672 ............................. 2/98, 2/129, 3/24, 5/55, 5/65, 5/69,
................................................. 5/74, 5/113, 5/128, 5/132, 5/155
6AV7674 ......................................... 3/16, 3/17, 3/18, 3/19, 3/20
6AV7675 .................................................................... 3/28, 3/31
6AV7860 ..................................................... 5/128, 5/132, 5/137
6AV7861 ........................................................... 3/13, 5/132, 6/9
6AV7862 ........................................................................... 5/137
6AV7863 ........................................................................... 5/128
6AV7872 ............................................................................. 6/43
6AV7881 ............................................................................. 5/55
6AV7883 ............................ 3/9, 3/10, 5/64, 5/111, 5/112, 5/113
6AV7884 ................................. 5/64, 5/111, 5/112, 5/113, 5/115
6AV7885 ............................................................................. 5/68
6AV789 ...................................................................... 3/23, 5/73
6AV7890 ............................................................................. 5/74
6AV7891 ............................................................................. 5/74
6AV7892 ............................................................................. 5/74
6AV7893 ............................................................................. 5/74
6AV7894 ............................................................................. 5/74
6AV9
6AV9681 ........................................................................... 4/142
6DL5
6DL5000 ........................................................................... 4/137
6DL5002 ........................................................................... 4/137
6DL5101 ........................................................................... 4/137
6ED1
6ED1056 ........................................................................... 2/117
6EP1
6EP1931 ................................................................ 5/181, 5/182
6EP1935 .......................................... 5/177, 5/182, 5/183, 5/184

Siemens ST 80 / ST PC · 2013

7/25

7

© Siemens AG 2013

Appendix
Order No. Index
6ES7

6GK5

6ES7193 ........................................................................... 2/108
6ES7272 ........................................................................... 2/136
6ES7623 ........................................................................... 2/138
6ES7647 ....................................... 5/33, 5/42, 5/45, 5/48, 5/207
6ES7648 ............................. 2/117, 3/24, 5/11, 5/18, 5/26, 5/33,
........................................... 5/42, 5/46, 5/49, 5/74, 5/106, 5/155,
................................... 5/160, 5/159, 5/160, 5/163, 5/164, 5/165,
................................................................................ 5/167, 5/169
6ES7657 ........................................................................... 4/109
6ES7658 ......................................................... 4/37, 4/77, 4/111
6ES7671 ......................................................... 5/82, 5/89, 5/115
6ES7675 ................................................................ 5/105, 5/106
6ES7677 .................................................................. 5/99, 5/100
6ES7806 ............................................................................. 5/90
6ES7820 ........................................................................... 5/204
6ES7840 ........................................................................... 4/114
6ES7900 ............ 3/24, 5/11, 5/18, 5/26, 5/46, 5/49, 5/74, 5/161
6ES7901 ....................................................... 2/109, 2/115, 4/70
6ES7972 ......................................................... 2/109, 4/30, 4/70

6GK5204
6GK5784
6GK5786
6GK5788
6GK5791
6GT2

6GT2190 ........................................................................... 2/103
6GT2600 ........................................................................... 2/103
6XV1
6XV1440 .................................................................. 2/115, 6/34
6XV1830 ............................... 2/115, 5/210, 5/212, 5/214, 5/216
6XV1840 ................................................................ 2/110, 2/111
6XV1870 ................... 2/110, 2/111, 2/115, 5/187, 5/188, 5/190,
..................................................................... 5/191, 5/192, 5/193
6XV1871 ........................................................................... 2/111
A5E

6GF6220 ........................................................................... 5/134

A5E01064980 ..................................................................... 5/26
A5E02396171 ..................................................................... 5/18
A5E31477788 ..................................................................... 2/10

6GK1

C794

6GK1160 ............................................. 5/82, 5/89, 5/106, 5/187
6GK1161 .......................... 4/29, 4/70, 4/103, 4/104, 5/82, 5/89,
.......................................................... 5/188, 5/189, 5/191, 5/195
6GK1162 ................................ 4/29, 4/103, 5/192, 5/193, 5/195
6GK1500 .................. 2/109, 5/210, 5/212, 5/214, 5/216, 5/218,
.......................................................... 5/220, 5/222, 5/224, 5/226
6GK1551 .................................. 4/30, 4/70, 4/103, 4/105, 5/219
6GK1560 ............................................. 5/82, 5/89, 5/106, 5/209
6GK1561 ........................ 4/30, 4/70, 4/103, 4/104, 4/105, 5/82,
................................................ 5/89, 5/209, 5/211, 5/213, 5/215,
................................................................................ 5/217, 5/221
6GK1562 ........................ 4/30, 4/70, 4/103, 4/104, 4/105, 5/82,
............................................................ 5/89, 5/215, 5/217, 5/223
6GK1571 ............................................. 4/30, 4/70, 4/103, 5/225

C79459 ............................................................................. 5/220

6GF6

7

.................................................... 5/187, 5/188, 5/198
............................................................... 2/102, 2/103
............................................................... 2/102, 2/103
............................................................... 2/102, 2/103
.......................................................................... 2/103

6GK1704 .................... 4/29, 4/103, 5/104, 5/189, 5/190, 5/197,
................................... 5/200, 5/219, 5/220, 5/221, 5/222, 5/223,
............................................... 5/224, 5/225, 5/226, 5/227, 5/228
6GK1706 ........ 5/190, 5/197, 5/202, 5/204, 5/205, 5/206, 5/230
6GK1711 .......................................................................... 5/198
6GK1713 ...................... 4/30, 4/70, 4/104, 4/105, 5/210, 5/211,
................................... 5/212, 5/213, 5/214, 5/215, 5/216, 5/217,
........................................................................................... 5/218
6GK1716 ...................... 4/29, 4/70, 4/103, 4/104, 4/105, 5/191,
..................................................................... 5/192, 5/193, 5/195
6GK1781 .......................................................................... 5/207
6GK1901 ............................................................... 2/110, 2/111
6GK1905 ......................................... 5/210, 5/212, 5/214, 5/216
6GK1975 .......................................................................... 2/109

7/26

Siemens ST 80 / ST PC · 2013

W790
W79084 ............................................................................ 2/138

© Siemens AG 2013

Appendix
Length key for connecting cables
■ Length key for connecting cables
On connecting cables whose length is freely selectable according to the following lists, the blanks (…) in the order no. must be
completed in accordance with the length codes given.

Length of the connecting cable =
Multiplier x length key

The different length keys must be taken into account here!
Other lengths on request.

Multiplier

Order no. supplement of the
connecting cable
6XV7 777-77777

• 0.01 m

E

• 0.1 m

H

• 1.0 m

N

• 10.0 m

T

• 100.0 m

U

Length digit
• 10

10

• 12

12

• 15

15

• 16

16

• 20

20

• 25

25

• 32

32

• 40

40

• 50

50

• 60

60

• 63

63

• 80

80

Ordering example:
The 6XV1 404-0A… connecting cable must be 16 m long.
Multiplier 1.0 m (N) x length digit 16 (16) gives a length of 16 m.
The order no. supplement is N16.
This is entered in the blank spaces of the order no.
The complete order no. for the 16 m long connecting cable is
then 6XV1 404-0AN16.

7

Siemens ST 80 / ST PC · 2013

7/27

© Siemens AG 2013

Appendix
Catalog improvement suggestions
Fax form

■
To

Your address

Siemens AG
I IA AS S ID 2
ST 80 / ST PC 2013 / Ms. Beyer
Gleiwitzer Str. 555
90475 Nürnberg

Name

Fax: +49 (911) 895-153114

Job

E-mail: barbara.beyer@siemens.com
Company/Department

Street/No.

Postal code/City

Tel. No./Fax

E-mail address

■ Your opinion is important to us!
Our catalog should be an important and frequently used
document. For this reason we are continuously endeavoring to
improve it.

A small request on our part to you:
Please take time to fill in the following form and fax it to us.
Thank You!

■ We invite you to grade our catalog on a point system from 1 (= good) to 6 (= poor):
Do the contents of the catalog live up to your expectations?

Do the technical details meet your expectations?

Is the information easy to find?

How would you assess the graphics and tables?

Can the texts be readily understood?

■ Did you find any printing errors?

7

7/28

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Appendix
Notes

7

Siemens ST 80 / ST PC · 2013

7/29

© Siemens AG 2013

Appendix
Notes

7

7/30

Siemens ST 80 / ST PC · 2013

© Siemens AG 2013

Appendix
Notes

7

Siemens ST 80 / ST PC · 2013

7/31

© Siemens AG 2013

Appendix
Conditions of sale and delivery

■ 1. General Provisions
By using this catalog you can acquire hardware and software
products described therein from Siemens AG subject to the
following Terms and Conditions of Sale and Delivery (hereinafter
referred to as "T&C"). Please note that the scope, the quality and
the conditions for supplies and services, including software
products, by any Siemens entity having a registered office
outside Germany, shall be subject exclusively to the General
Terms and Conditions of the respective Siemens entity. The
following T&C apply exclusively for orders placed with Siemens
Aktiengesellschaft, Germany.
1.1 For customers with a seat or registered office in
Germany
For customers with a seat or registered office in Germany, the
following applies subordinate to the T&C:
• the "General Terms of Payment"1) and,
• for software products, the "General License Conditions for
Software Products for Automation and Drives for Customers
with a Seat or Registered Office in Germany"1) and,
• for other supplies and services, the "General Conditions for
the Supply of Products and Services of the Electrical and
Electronics Industry"1).
1.2 For customers with a seat or registered office outside
Germany
For customers with a seat or registered office outside Germany,
the following applies subordinate to the T&C:
• the "General Terms of Payment"1) and,
• for software products, the "General License Conditions for
Software Products for Automation and Drives for Customers
with a Seat or Registered Office outside of Germany"1) and
• for other supplies and/or services, the "General Conditions for
Supplies of Siemens Industry for Customers with a Seat or
Registered Office outside of Germany"1).

■ 2. Prices

7

The prices are in € (Euro) ex point of delivery, exclusive of
packaging.
The sales tax (value added tax) is not included in the prices. It
shall be charged separately at the respective rate according to
the applicable statutory legal regulations.
Prices are subject to change without prior notice. We will charget
the prices valid at the time of delivery.
To compensate for variations in the price of raw materials (e.g.
silver, copper, aluminum, lead, gold, dysprosium and neodym),
surcharges are calculated on a daily basis using the so-called
metal factor for products containing these raw materials. A
surcharge for the respective raw material is calculated as a
supplement to the price of a product if the basic official price of
the raw material in question is exceeded.
The metal factor of a product indicates the basic official price
(for those raw materials concerned) as of which the surcharges
on the price of the product are applied, and with what method of
calculation.
An exact explanation of the metal factor can be downloaded at:
www.siemens.com/automation/salesmaterial-as/catalog/en/
terms_of_trade_en.pdf
To calculate the surcharge (except in the cases of dysprosium
and neodym), the official price from the day prior to that on which
the order was received or the release order was effected is used.
To calculate the surcharge applicable to dysprosium and
neodym ("rare earths"), the corresponding three-month basic
average price in the quarter prior to that in which the order was
received or the release order was effected is used with a onemonth buffer (details on the calculation can be found in the
explanation of the metal factor).

7/32

Siemens ST 80 / ST PC · 2013

■ 3. Additional Terms and Conditions
The dimensions are in mm. In Germany, according to the
German law on units in measuring technology, data in inches
apply only to devices for export.
Illustrations are not binding.
Insofar as there are no remarks on the individual pages of this
catalog - especially with regard to data, dimensions and weights
given - these are subject to change without prior notice.

■ 4. Export regulations
We shall not be obligated to fulfill any agreement if such
fulfillment is prevented by any impediments arising out of
national or international foreign trade or customs requirements
or any embargoes and/or other sanctions.
Export of goods listed in this catalog may be subject to licensing
requirements. We will indicate in the delivery details whether
licenses are required under German, European and US export
lists. Goods labeled with "AL" not equal to "N" are subject to
European or German export authorization when being exported
out of the EU. Goods labeled with "ECCN" not equal to "N" are
subject to US re-export authorization.
The export indications can be viewed in advance in the
description of the respective goods on the Industry Mall, our
online catalog system. Only the export labels "AL" and "ECCN"
indicated on order confirmations, delivery notes and invoices
are authoritative.
Even without a label, or with label "AL:N" or "ECCN:N", authorization may be required i .a. due to the final disposition and
intended use of goods.
If you transfer goods (hardware and/or software and/or
technology as well as corresponding documentation, regardless
of the mode of provision) delivered by us or works and services
(including all kinds of technical support) performed by us to a
third party worldwide, you must comply with all applicable
national and international (re-)export control regulations.
If required for the purpose of conducting export control checks,
you (upon request by us) shall promptly provide us with all information pertaining to the particular end customer, final disposition and intended use of goods delivered by us respectively
works and services provided by us, as well as to any export
control restrictions existing in this relation.
The products listed in this catalog may be subject to
European/German and/or US export regulations. Any export
requiring approval is therefore subject to authorization by the
relevant authorities.
Errors excepted and subject to change without prior notice.

1) The text of the Terms and Conditions of Siemens AG can be
downloaded at
www.siemens.com/automation/salesmaterial-as/catalog/en/
terms_of_trade_en.pdf

© Siemens AG 2013

Catalogs
Industry Automation, Drive Technologies and Low-Voltage Power Distribution
Further information can be obtained from our branch offices
listed at www.siemens.com/automation/partner
System Solutions
Interactive Catalog on DVD

Catalog

Low-Voltage Power Distribution and
Electrical Installation Technology

Catalog

Products for Automation and Drives and
Low Voltage Power Distribution

CA 01

SENTRON Protection, Switching, Measuring and
Monitoring Devices
SIVACON · ALPHA Switchboards and
Distribution Systems
Standards-Compliant Components for
Photovoltaic Plants
3WT Air Circuit Breakers up to 4000 A
3VT Molded Case Circuit Breakers up to 1600 A
Digital: SIVACON System Cubicles, System Lighting
and System Air-Conditioning
Digital: ALPHA Distribution Systems
ALPHA FIX Terminal Blocks
SIVACON S4 Power Distribution Boards
SIVACON 8PS Busbar Trunking Systems

LV 10.1

Building Control
GAMMA Building Control
Drive Systems
SINAMICS G130 Drive Converter Chassis Units
SINAMICS G150 Drive Converter Cabinet Units
SINAMICS GM150, SINAMICS SM150
Medium-Voltage Converters
ROBICON Perfect Harmony
Medium-Voltage Air-Cooled Drives
Germany Edition
Digital: SINAMICS G180
Converters – Compact Units, Cabinet Systems,
Cabinet Units Air-Cooled and Liquid-Cooled
SINAMICS S120 Chassis Format Units and
Cabinet Modules
SINAMICS S150 Converter Cabinet Units
SINAMICS DCM Converter Units
SINAMICS DCM Cabinet
SINAMICS and Motors for Single-Axis Drives
Three-Phase Induction Motors SIMOTICS HV,
SIMOTICS TN
• Series H-compact
• Series H-compact PLUS
Asynchronous Motors Standardline
Synchronous Motors with Permanent-Magnet
Technology, HT-direct
DC Motors
SIMOREG DC MASTER 6RA70 Digital Chassis
Converters
SIMOREG K 6RA22 Analog Chassis Converters
Digital: SIMOREG DC MASTER 6RM70 Digital
Converter Cabinet Units
SIMOVERT PM Modular Converter Systems
SIEMOSYN Motors
MICROMASTER 420/430/440 Inverters
MICROMASTER 411/COMBIMASTER 411
SIMOVERT MASTERDRIVES Vector Control
SIMOVERT MASTERDRIVES Motion Control
Synchronous and asynchronous servomotors for
SIMOVERT MASTERDRIVES
SIMODRIVE 611 universal and POSMO

ET G1

D 11
D 12
D 15.1

D 18.1

D 21.3

D 23.1
D 23.2
D 31
D 84.1

D 86.1
D 86.2
DA 12
DA 21.1
DA 21.2
DA 22
DA 45
DA 48
DA 51.2
DA 51.3
DA 65.10
DA 65.11
DA 65.3

Low-Voltage Three-Phase-Motors
SIMOTICS Low-Voltage Motors
MOTOX Geared Motors
SIMOGEAR Geared Motors
SIMOGEAR Gearboxes with adapter

D 81.1
D 87.1
MD 50.1
MD 50.11

Mechanical Driving Machines
FLENDER Standard Couplings
FLENDER High Performance Couplings
FLENDER SIG Standard industrial gear unit
FLENDER SIP Standard industrial planetary gear units

MD 10.1
MD 10.2
MD 30.1
MD 31.1

Digital: These catalogs are only available as a PDF
and/or as an e-book.

LV 11
LV 35
LV 36
LV 50
LV 51
LV 52
LV 56
LV 70

NC 60
NC 61
NC 62
NC 81.1
NC 82
PM 21
CR 1

Power Supply and System Cabling
Power supply SITOP

KT 10.1

Safety Integrated
Safety Technology for Factory Automation

SI 10

SIMATIC HMI/PC-based Automation
Human Machine Interface Systems/
PC-based Automation

ST 80/
ST PC

SIMATIC Ident
Industrial Identification Systems

ID 10

DA 65.4

Note: Additional catalogs on SIMODRIVE or SINAMICS
drive systems and SIMOTICS motors with SINUMERIK
and SIMOTION can be found under Motion Control

Process Instrumentation and Analytics
Field Instruments for Process Automation
Digital: SIPART Controllers and Software
Products for Weighing Technology
Digital: Process Analytical Instruments
Digital: Process Analytics,
Components for the System Integration

Motion Control
SINUMERIK & SIMODRIVE
Automation Systems for Machine Tools
SINUMERIK & SINAMICS
Equipment for Machine Tools
SINUMERIK 840D sl Type 1B
Equipment for Machine Tools
SINUMERIK 808D, SINAMICS V60 and G120,
SIMOTICS 1FL5 and 1LE1
SINUMERIK 828D BASIC T/BASIC M,
SINAMICS S120 Combi, 1FK7 and 1PH8 motors
SIMOTION, SINAMICS S120 & SIMOTICS
Equipment for Production Machines
Drive and Control Components for Cranes

LV 10.2

FI 01
MP 31
WT 10
PA 01
PA 11

SIMATIC Industrial Automation Systems
Products for Totally Integrated Automation
SIMATIC PCS 7 Process Control System
Add-ons for the SIMATIC PCS 7
Process Control System
Digital: Migration solutions with the SIMATIC PCS 7
Process Control System
SIMATIC NET
Industrial Communication

ST 70
ST PCS 7
ST PCS 7.1
ST PCS 7.2

IK PI

SINVERT Photovoltaics
Inverters and Components for Photovoltaic Installations RE 10
SIRIUS Industrial Controls
SIRIUS Industrial Controls

IC 10

Information and Download Center
PDF versions of the catalogs are available on the Internet at:
www.siemens.com/industry/infocenter
There you’ll find additional catalogs in other languages.
Please note the section “Downloading catalogs” on page
“Online services” in the appendix of this catalog.

© Siemens AG 2013

Siemens AG
Industry Sector
Industrial Automation Systems
Postfach 48 48
90026 NÜRNBERG
GERMANY

Subject to change without prior notice
Order No. E86060-K4680-A101-C1-7600
MQ.R0.R1.0000.04.3.01 / Dispo 07900
KG 0813 3. AUM 672 En / IWI TSTE
Printed in Germany
© Siemens AG 2013

The information provided in this catalog contains descriptions or
characteristics of performance which in case of actual use do not
always apply as described or which may change as a result of further
development of the products. An obligation to provide the respective
characteristics shall only exist if expressly agreed in the terms of
contract. Availability and technical specifications are subject to
change without notice.
All product designations may be trademarks or product names
of Siemens AG or supplier companies whose use by third parties
for their own purposes could violate the rights of the owners.

www.siemens.com/automation

SO_Umschlag_KG_ST80_STPC_2013_en.indd 2

05.08.2013 13:48:18



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : I IA AS S ID 2
Create Date                     : 2013:08:05 13:49:35+02:00
Keywords                        : E86060-D4001-A510-D2-7600
Modify Date                     : 2013:10:25 13:48:11+02:00
Has XFA                         : No
Language                        : en
XMP Toolkit                     : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26
Producer                        : Acrobat Distiller 9.5.5 (Windows)
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2013:10:25 13:48:11+02:00
Format                          : application/pdf
Description                     : Catalog
Title                           : SIMATIC HMI / PC-based Automation Operator Control and Monitoring Systems
Creator                         : I IA AS S ID 2, I IA CC PRI
Subject                         : E86060-D4001-A510-D2-7600
Rights                          : © Siemens AG 2013
Document ID                     : uuid:3d8d011a-8af9-4647-9fae-49e208bdda84
Instance ID                     : uuid:4ae5b097-81b6-4bf3-8213-85f507566bfe
Marked                          : True
Startup Profile                 : Print
Page Layout                     : SinglePage
Page Mode                       : UseOutlines
Page Count                      : 676
Signing Date                    : 2013:10:25 13:47:56+02:00
Signing Authority               : ARE Acrobat Product v8.0 P23 0002337
Annotation Usage Rights         : Create, Delete, Modify, Copy, Import, Export
EXIF Metadata provided by EXIF.tools

Navigation menu