SIMATIC HMI / PC Based Automation Operator Control And Monitoring Systems 1000471964 Catalog

2016-10-06

: Pdf 1000471964-Catalog 1000471964-Catalog B5 unilog

Open the PDF directly: View PDF PDF.
Page Count: 676 [warning: Documents this large are best viewed by clicking the View PDF Link!]

SIMATIC HMI / PC-based Automation
Human Machine Interface Systems/
PC-based Automation
Answers for industry.
Catalog
ST 80/
ST PC
Edition
2013
SO_Umschlag_KG_ST80_STPC_2013_en.indd 3SO_Umschlag_KG_ST80_STPC_2013_en.indd 3 05.08.2013 13:48:2505.08.2013 13:48:25
© Siemens AG 2013
SIMATIC ST 70
Products for
Totally Integrated Automation
E86060-K4670-A101-B4-7600
Industrial Communication IK PI
SIMATIC NET
E86060-K6710-A101-B7-7600
SITOP KT 10.1
Power supply
SITOP
E86060-K2410-A111-A9-7600
SITRAIN ITC
Training for Automation and
Industrial Solutions
Only available in German
E86060-K6850-A101-C3
Products for Automation CA 01
and Drives
Interactive Catalog, DVD
E86060-D4001-A510-D2-7600
Mall
Information and Ordering Platform
in the Internet:
www.siemens.com/industrymall
Related catalogs
U2_ST80-STPC.fm Seite 1 Freitag, 2. August 2013 3:41 15
© Siemens AG 2013
SIMATIC HMI /
PC-based Automation
Operator Control and
Monitoring Systems
Catalog ST 80 / ST PC · 2013
Supersedes:
Catalog ST 80 / ST PC · 2012
Refer to the Industry Mall for current updates
of this catalog:
www.siemens.com/industrymall
The products contained in this
catalog can also be found in the
Interactive Catalog CA 01.
Order No.:
E86060-D4001-A510-D2-7600
Please contact your local Siemens branch.
© Siemens AG 2013
The products and sys-
tems described in this
catalog are manufac-
tured/distributed under
application of a certified
quality management
system in accordance
with DIN EN ISO 9001
(Certified Registration
No. 2613-05). The certif-
icate is recognized by all
IQNet countries.
Introduction
1
Operator panels
2
HMI devices for special requirements
3
HMI Software
4
PC-based Automation
5
Customized Automation
6
Appendix
7
Printed on paper
from sustainably
managed forests and
controlled sources.
www.pefc.org
Vorspann_EN.book Seite 1 Freitag, 2. August 2013 3:32 15
© Siemens AG 2013
2Siemens ST 80 / ST PC · 2013
Vorspann_EN.book Seite 2 Freitag, 2. August 2013 3:32 15
© Siemens AG 2013
3
Siemens ST 80 / ST PC · 2013
Answers for industry.
Integrated technologies, vertical market expertise and services
for greater productivity, energy efficiency, and flexibility.
The Siemens Industry Sector is the
world's leading supplier of innovative
and environmentally friendly products
and solutions for industrial companies.
End-to-end automation technology and
industrial software, solid market exper-
tise, and technology-based services are
the levers we use to increase our cus-
tomers’ productivity, efficiency and
flexibility. With a global workforce of
more than 100 000 employees,
the Industry Sector comprises the
Industry Automation, Drive Technolo-
gies, and Customer Services divisions,
as well as the Metals Technologies
Business Unit.
We consistently rely on integrated tech-
nologies and, thanks to our bundled
portfolio, we can respond more quickly
and flexibly to our customers' wishes.
With our globally unmatched range of
automation technology, industrial
control and drive technology as well
as industrial software, we equip compa-
nies with exactly what they need over
their entire value chain – from product
design and development to production,
sales and service. Our industrial custom-
ers benefit from our comprehensive
portfolio, which is tailored to their
market and their needs.
Market launch times can be reduced by
up to 50% due to the combination of
powerful automation technology and
intelligent industrial software from
Siemens Industry. At the same time,
the costs for energy or waste water
for a manufacturing company can be
reduced significantly. In this way, we
increase our customers’ competitive
strength and make an important contri-
bution to environmental protection
with our energy-efficient products and
solutions.
Vorspann_EN.book Seite 3 Freitag, 2. August 2013 3:32 15
© Siemens AG 2013
4Siemens ST 80 / ST PC · 2013
&RQWURO/HYHO
0DQDJHPHQW/HYHO
2SHUDWLRQV/HYHO 6,0$7,&3&6
2SHUDWRU6\VWHP
6,0$7,&,7
0DLQWHQDQFH
$VVHW0DQDJHPHQW
(QJLQHHULQJ
6WDWLRQ
(QHUJ\
0DQDJHPHQW
0(6²0DQXIDFWXULQJ([HFXWLRQ6\VWHPV
(53²(QWHUSULVH5HVRXUFH3ODQQLQJ
6,180(5,.
&RPSXWHU1XPHULF&RQWURO
6,0$7,&3&6
$XWRPDWLRQ
6\VWHPV
6,027,21
0RWLRQ&RQWURO
6,0$7,&1(7
,QGXVWULDO
&RPPXQLFDWLRQ
6,0$7,&,GHQW
,QGXVWULDO,GHQWLÀFDWLRQ
3URFHVV,QVWUXPHQWDWLRQ
)LHOG/HYHO
7RWDOO\
,QWHJUDWHG
$XWRPDWLRQ
+$57
352),%863$
7,$3RUWDO
6,0$7,&&RQWUROOHUV
0RGXODU3&EDVHG
6,0$7,&'LVWULEXWHG,2
,2/LQN
3/0²3URGXFW/LIHF\FOH0DQDJHPHQW 3URGXFW'HVLJQ
3URGXFWLRQ3ODQQLQJDQG6LPXODWLRQ
'DWD0DQDJHPHQW
Setting standards in
productivity and competitiveness.
Totally Integrated Automation.
Vorspann_EN.book Seite 4 Freitag, 2. August 2013 3:32 15
© Siemens AG 2013
5
Siemens ST 80 / ST PC · 2013
&2026
3ODQW(QJLQHHULQJ
6,0$7,&:LQ&&
6&$'$6\VWHP
(WKHUQHW
6,5,86,QGXVWULDO&RQWUROV
6,0$7,&+0,
+XPDQ0DFKLQH,QWHUIDFH
,QGXVWULDO(WKHUQHW
/RZ9ROWDJH'LVWULEXWLRQ
6,027,&60RWRUV
6,1$0,&6'ULYH6\VWHPV
7RWDOO\
,QWHJUDWHG
3RZHU
352),1(7
,QGXVWULDO(WKHUQHW
352),%86
$6,QWHUIDFH
.1;*$00$LQVWDEXV
6,7233RZHU6XSSO\
Thanks to Totally Integrated Automation, Siemens provides
an integrated basis for the implementation of customized
automation solutions – in all industries from inbound to
outbound.
TIA is characterized by its unique continuity.
It provides maximum transparency at all levels
with reduced interfacing requirements – covering
the field level, production control level, up to the
corporate management level. With TIA you also
profit throughout the complete life cycle of your
plant – starting with the initial planning steps
through operation up to modernization, where
we offer a high measure of investment security re-
sulting from continuity in the further development
of our products and from reducing the number of
interfaces to a minimum.
The unique continuity is already a defined
characteristic at the development stage of
our products and systems.
The result: maximum interoperability – covering
the controller, HMI, drives, up to the process
control system. This reduces the complexity of
the automation solution in your plant. You will
experience this, for example, in the engineering
phase of the automation solution in the form of
reduced time requirements and cost, or during
operation using the continuous diagnostics facili-
ties of Totally Integrated Automation for increas-
ing the availability of your plant.
Vorspann_EN.book Seite 5 Freitag, 2. August 2013 3:32 15
© Siemens AG 2013
6Siemens ST 80 / ST PC · 2013
Totally Integrated Power:
Future-proof power supply
from one source.
Vorspann_EN.book Seite 6 Freitag, 2. August 2013 3:32 15
© Siemens AG 2013
U
I
cos o
P
W
Substation
Distribution
Maintenance
task
Hall 1 Air conditioning system
checkup
Distribution 3 Replacing circuit
breaker contacts
Infeed II Replacing meters
central ON
OFF
local ON
OFF
tripped
TOTAL HOURS
DATE
IN
OUT
IN
OUT
OVERTIME
SUN MON TUE WED THUR FRI SAT SUN TOTAL
TOTAL HOURS
DATE
IN
OUT
IN
OUT
OVERTIME
SUN MON TUE WED THUR FRI SAT SUN TOTAL
TOTAL HOURS
DATE
IN
OUT
IN
OUT
OVERTIME
SUN MON TUE WED THUR FRI SAT SUN TOTAL
DATE:
EMPLOYEE
COST CENTER
PAY PERIOD BEGINNING
PAY PERIOD ENDING
Energy Management/
Energy Transparency
Products & Systems
Process/
industrial automation
Planning Software Tools
Medium voltage with
protection technology
Network dimensioning
with SIMARIS design
Space requirements and budget calculation
with SIMARIS project
TransformerRenewables Low voltage with
protection and measuring technology
Visualization of device characteristics
with SIMARIS curves
Operation &
Monitoring
Load
management
Load curves Forecast Maintenance Status
reporting/
failure
management
Protocols Power
Quality
Cost center
Building
automation
≤ 110 kV
7
Siemens ST 80 / ST PC · 2013
The power supply system acts like a
“vital artery”, forming the basis for
the reliable and efficient functioning
of all electrically operated building
installations. Electrical power distribu-
tion therefore requires integrated
solutions. Our answer:
Totally Integrated Power (TIP).
This includes software tools and
support for planning and configuration
and a complete, optimally aligned
product and system portfolio for
integrated power distribution from
medium-voltage switchgear right to
socket outlets.
The power distribution products and
systems can be interfaced to building
or industrial automation systems
(Total Building Solutions or
Totally Integrated Automation) via
communication-capable circuit breakers
and components, allowing the full po-
tential for optimization that an inte-
grated solution offers to be exploited
throughout the project cycle – from
planning right through to installation
and operation.
Get more information:
www.siemens.com/tip
www.siemens.com/simaris
www.siemens.com/specifications
Software tools, products, systems and
support for integrated electrical
power distribution
Vorspann_EN.book Seite 7 Freitag, 2. August 2013 3:32 15
© Siemens AG 2013
8Siemens ST 80 / ST PC · 2013
Vorspann_EN.book Seite 8 Freitag, 2. August 2013 3:32 15
© Siemens AG 2013
Siemens ST 80 / ST PC · 2013
1
1/2 Introduction
1/2 SIMATIC HMI operator control and
monitoring systems
1/8 SIMATIC PC-based Automation
Operator control and
monitoring systems /
PC-based Automation
ST80_2013_EN_Kap01.book Seite 1 Freitag, 2. August 2013 3:13 15
© Siemens AG 2013
Introduction
Gain transparency and lower costs
SIMATIC HMI operator control and
monitoring systems
1/2 Siemens ST 80 / ST PC · 2013
1
Overview
The interface between human and machine –
the human machine interface or HMI for short –
connects the world of automation with the
individual requirements of the operator.
Human machine interfacing is about managing
the process, optimizing machine and system
operation, availability and productivity.
ST80_2013_EN_Kap01.book Seite 2 Freitag, 2. August 2013 3:13 15
© Siemens AG 2013
Introduction
Gain transparency and lower costs
SIMATIC HMI operator control and
monitoring systems
1/3
Siemens ST 80 / ST PC · 2013
Overview (continued)
Everything from a single source
With SIMATIC HMI, Siemens Automation and Drives offers a
complete range of innovative and low-cost products and
systems for the multi-faceted tasks of operator control and
monitoring: Ranging from operator panels and visualization
software for operator control and monitoring at the machine
through to SCADA systems for widely differing requirements in
process visualization. For special requirements, optimally
adapted products are offered such as especially rugged HMI
devices with all-round protection for mounting on support arms/
pedestals, or operator panels with stainless steel front for use in
the food and beverages industry. Of course, individual,
customer-specific requirements can also be implemented.
Perfectly equipped for integration
in the world of automation
With their open, standardized interfaces in hardware and
software, SIMATIC HMI products can be integrated at any time
in the production and automation level as well as in the company
management level. Connectability to almost every controller on
the market as well as multiple language capability of the config-
uration and visualization software – including Asian ideographic
languages, of course – facilitate operation worldwide.
Increased production transparency
through Plant Intelligence
Plant Intelligence is based on the intelligent utilization of infor-
mation to improve processes within the company.
It is designed to lower plant costs, consolidate and improve
quality, avoid wastage, utilize production facilities better and
ultimately ensure greater efficiency and cost effectiveness within
the company. WinCC provides the best requirements for
achieving this since WinCC features an integrated Historian for
acquiring important production data.
Using intelligent functions and tools, this process data can be
edited into information necessary for making decisions and can
be made available throughout the company whenever and
wherever it is required – for operators as well as production
managers or anyone else within the company.
Even the WinCC basic system provides a wealth of display and
evaluation functions, such as the statistics function for the
message and measured value logs. WinCC options for IT &
business integration make additional "smart" tools available for
optimizing production using Plant Intelligence.
Integrated into the World Wide Web
SIMATIC HMI makes the Internet into a control desk - within a
plant as well as in the worldwide network.
Using the WinCC/Web Navigator, you can monitor and operate
plants over the Internet or over the internal corporate intranet.
Thin client solutions can be used to integrate rugged, local
devices which simultaneously establish the connection between
the automation level and the control center. And over a wireless
LAN or cell phone connection, you can use mobile thin clients
such as laptop computers, PDAs (personal digital assistants) or
WebPads.
In this way, process, service or management information can be
made individually available to users. At the machine level, many
control units support remote operation, e.g. as a link between
the automation level and the control room through to service and
diagnostics over the Internet.
For operation and monitoring at the machine, concepts with so-
called Sm@rtClients and servers facilitate plant-wide access to
variables and graphics, distributed operator stations as well as
remote operation and diagnostics via the Internet – also in
conjunction with SIMATIC Panels.
www.siemens.com/simatic-hmi
ST80_2013_EN_Kap01.book Seite 3 Freitag, 2. August 2013 3:13 15
© Siemens AG 2013
Introduction
Gain transparency and lower costs
SIMATIC HMI operator control and
monitoring systems
1/4 Siemens ST 80 / ST PC · 2013
Overview (continued)
1
Traceability and easy validation
SIMATIC HMI software with "FDA options" provides a high
degree of support to machine and plant manufacturers who
must fulfill high quality requirements, both with respect to the
products to be manufactured as well as to the manufacturing
processes themselves.
These options simplify plant validation enormously and thus
provide the most convincing and comprehensive solution for the
requirements of these industries.
They support the user in fulfilling high quality requirements as
specified by the FDA (Food and Drug Administration) 21 CFR
Part 11 for the food, beverages and pharmaceutical industries.
Increased plant availability
All operator panels and Panel PCs are designed for harsh indus-
trial use. Redundant process visualization systems ensure a
high degree of plant availability during normal operation.
Distributed operator control concepts
SIMATIC HMI offers different solutions for different requirements
for operator control of large machines and plants spread over
extensive areas.
Thus, the Sm@rtAccess option of the SIMATIC WinCC flexible
visualization software, for example, allows HMI devices such as
panels, Thin Clients and PCs plant-wide access via PROFINET/
Ethernet to current process values and the local screen images
of all involved stations.
SIMATIC HMI software offers appropriate options for
diagnostics, maintenance and telecontrol over the Internet from
local operator stations.
As remote operator stations, SIMATIC Thin Clients make the
functionality of machine-level panels available in the control
room or in the office, thanks to their connection to PROFINET/
Ethernet, and in the other direction, they bring SIMATIC WinCC
or office or IT functionality straight to the machine.
In PC-based applications, a SIMATIC Flat Panel monitor can take
over the function of the operating unit from PCs, such as
SIMATIC Rack or Box PC, at a distance of up to 30 m.
More than just operator control and monitoring
The Multi Panels under Windows CE combine the advantages of
two worlds: On the one hand, the ruggedness of an operator
panel and on the other hand the flexibility typical of a PC.
Apart from classical operator control and monitoring, other
automation functions such as control functions can execute
simultaneously. And for PC-based automation, the SIMATIC
Panel PCs are available as a compact automation platform - the
embedded versions being especially compact and rugged as
well as maintenance-free.
ST80_2013_EN_Kap01.book Seite 4 Freitag, 2. August 2013 3:13 15
© Siemens AG 2013
Introduction
Gain transparency and lower costs
SIMATIC HMI operator control and
monitoring systems
1/5
Siemens ST 80 / ST PC · 2013
Overview (continued)
All the advantages of Totally Integrated Automation
With Totally Integrated Automation (TIA), Siemens is the only
supplier who offers a system-wide, integrated product and
system range for automating the complete production workflow.
The distinguishing feature of TIA is that it is completely
integrated. The reduced number of interfaces results in very
clear structures.
This reduces time and costs required for engineering the
automation solution and increases the availability of the plant.
In conjunction with other SIMATIC components, SIMATIC HMI
also supports system diagnostics and process diagnostics
during normal operation. You can start STEP 7 diagnostics
directly from WinCC for comprehensive error diagnostics from
the circuit diagram through to the PLC program.
The SIMATIC Maintenance Station visualizes the maintenance
information for the automation technology of a system – from the
controller and network components to switchgear, protective
equipment and control devices and the drives.
This gives a clear overview of the status of the automation at any
time.
A competent partner for automation solutions
With SIMATIC HMI, you not only get excellent products to suit
your requirements, we will also support you when selecting a
partner for your automation solution. In our worldwide network of
Siemens Automation Solution Partners, you will find competent
contact partners in your area who are always up-to-date with
SIMATIC HMI technology.
The Siemens-internal WinCC Competence Centers implement
technology-specific products as well as customer and industry-
specific solutions on the basis of WinCC.
WinCC specialists are external system integrators who combine
their WinCC expertise with their industry and technology know-
how to create tailor-made, cost-effective solutions. Numerous
products from our partners that perfectly interact with WinCC are
available as WinCC Add-ons.
Investment protection is included
Our many years of experience in the automation engineering
sector are to your advantage. The same applies to our global
service network with its expert support.
Further services, such as a software update service, training,
ordering over the Internet, etc. round off what we have to offer.
ST80_2013_EN_Kap01.book Seite 5 Freitag, 2. August 2013 3:13 15
© Siemens AG 2013
Introduction
A whole world of operator control and monitoring
SIMATIC HMI operator control and
monitoring systems
1/6 Siemens ST 80 / ST PC · 2013
1
SIMATIC® HMI®
HMI devices
SIMATIC HMI Key Panels
Operator panels with bus capability for easy and direct
operation of machines.
www.siemens.com/key-panels
SIMATIC HMI Basic Panels
Operator panels with basic functionality for low-cost operator
control and monitoring of simple applications.
www.siemens.com/basic-panels
SIMATIC HMI Comfort Panels
HMI devices with high-end functionality for demanding
applications.
www.siemens.com/comfort-panels
SIMATIC HMI Mobile Panels
Mobile operator panels with or without cables for direct operator
control of the plant and machine from any location.
www.siemens.com/simatic-mobile-panels
HMI devices for special requirements
Fully enclosed HMI devices for SIMATIC
The fully enclosed SIMATIC HMI devices (MP 377 PRO,
HMI IPC477C PRO, Flat Panel PRO and Thin Client PRO) are
ideal for industrial applications in harsh environments due to
their extremely robust design. They are, for example, specially
designed for mounting on a support arm/stand.
www.siemens.com/ip65-hmi-devices
Devices with stainless steel fronts
Panels and Panel PCs with touch screens and stainless steel
fronts are designed for machine-level operator control and
monitoring in the food, beverages and tobacco industry.
www.siemens.com/inox-hmi-devices
HMI devices for hazardous areas
Intrinsically safe Panel PCs and Thin Clients that were specifi-
cally developed for hazardous areas.
www.siemens.com/simatic-hmi-ex
HMI software
Flexibility in any HMI application – from Basic Panels through to
process visualization
SIMATIC WinCC in the Totally Integrated Automation Portal
(TIA Portal) is part of a new, integrated engineering framework
which offers a uniform engineering environment for
programming and configuration of control, visualization and
drive solutions.
WinCC in the TIA Portal is the software for all HMI applications
ranging from the simplest operation solutions with Basic Panels
to SCADA applications on PC-based multi-user systems.
www.siemens.com/tia-portal
SIMATIC WinCC V7 remains available for extremely complex
applications featuring Plant Intelligence solutions, integrated
archive servers or redundant architectures, whereas WinCC
Open Architecture addresses applications with demanding
customization requirements, also on non-Windows platforms.
www.siemens.com/wincc
WinCC Open Architecture adressiert Anwendungen mit
hohem kundenspezifischen Anpassungsbedarf – auch auf
Nicht-Windows-Plattformen.
www.siemens.com/wincc-open-architecture
Customized Automation
With Customized Automation, field-proven SIMATIC,
SIMATIC IPC and SIMATIC HMI standards are transferred to
individual products and systems – tailored precisely to the
customer's requirements. The portfolio covers the hardware and
software range, as well as support and logistics.
www.siemens.com/customized-automation
Process
visualization
Operator control
and monitoring
directly at the
machine
Single-user PC
Actuators / Sensors
Key Panels Basic Panels
SIMOTION
Motion Control
ST80_2013_EN_Kap01.book Seite 6 Freitag, 2. August 2013 3:13 15
© Siemens AG 2013
Introduction
A whole world of operator control and monitoring
SIMATIC HMI operator control and
monitoring systems
1/7
Siemens ST 80 / ST PC · 2013
Field devices
Additional automation systems
Panel PCs
Flat Panel monitors
SCADA system WinCCInternet client
Comfort Panels Mobile Panels Thin Clients
Plant Intelligence
Manufacturing Execution Systems (MES)
Enterprise Resource Planning (ERP)
S7-200 S7-1200 S7-300
S7-400
Software HMI
WinCC (TIA Portal)
G_ST80_XX_00365
Client/Server
SIMATIC Controller
Drives
ST80_2013_EN_Kap01.book Seite 7 Freitag, 2. August 2013 3:13 15
© Siemens AG 2013
Introduction
SIMATIC PC-based Automation
1/8 Siemens ST 80 / ST PC · 2013
1
Overview
SIMATIlC PC-based Automation
www.siemens.com/pc-based
Industrial PCs
Our reliable and innovative industrial PCs are the optimal PC
hardware platform for PC-based Automation from Siemens.
www.siemens.com/simatic-ipc
PC-based controllers
Siemens has developed a wide range of coordinated hardware
and software components for PC-based Automation. Focal
point: SIMATIC PC-based Control with SIMATIC WinAC, the
open, flexible and reliable software controller for your PC-based
automation solution, also approved by the German Technical
Inspectorate and fail-safe.
www.siemens.com/winac
Embedded controllers
SIMATIC S7-mEC is a modular controller in S7-300 design with
the latest embedded PC technology. It comprises the EC31
(CPU) as well as the optionally available expansion modules.
www.siemens.com/simatic-s7-mec
Embedded bundles with industrial PCs
Embedded bundles based on the embedded industrial PCs are
extremely compact, robust, and maintenance-free systems for
use at machine level. The functions PC-based Control (also fail-
safe) and/or visualization are already pre-installed and ready to
use.
www.siemens.com/simatic-embedded-bundles
Software packages for SIMATIC IPCs
SIMATIC industrial PCs are offered with low-cost software
packages. For the runtime versions with the visualization
software products SIMATIC WinCC or WinCC Professional,
WinCC flexible or WinCC Advanced, as well as the software
controller SIMATIC WinAC RTX (F). The simultaneous purchase
of industrial PC and software package results in the price
advantage.
www.siemens.com/simatic-ipc-packages
Industrial monitors and thin clients
Flexible distributed operating concepts can be implemented via
Flat Panel monitors and thin clients. These are industry-standard
LCD monitors with high-luminance displays that are placed up
to 30 m away from the PC, or high-performance industrial thin
clients. SIMATIC ITC, for one or even several operator stations,
can be placed as far away as required via Industrial Ethernet.
www.siemens.com/simatic-ifp
www.siemens.com/simatic-itc
SIMATIC WinCC
Visualization
Archive
Databases
SIMATIC HMI Panel
Operator control and
monitoring
SIMATIC Field PG
Configuration
Programming
STEP 7
WinCC, WinAC
Software PLC
SIMATIC Panel PC SIMATIC Rack PC
SIMATIC
Thin Client
WinAC (F)
Software PLC
WinAC (F)
Software PLC
SIMATIC Box PC
Nanobox PC/Microbox PC
SIMATIC Embedded Bundles:
IPC2x7D/IPC4x7C
S7-modular Embedded Controller
SIMATIC S7
ET 200 SIMOTION D / SINAMICS / MICROMASTER
PROFINET
PROFIBUS
G_ST70_XX_00169
Industrial Ethernet
PROFINET
ST80_2013_EN_Kap01.book Seite 8 Freitag, 2. August 2013 3:13 15
© Siemens AG 2013
Introduction
SIMATIC PC-based Automation
1/9
Siemens ST 80 / ST PC · 2013
Overview (continued)
Application examples
www.siemens.com/pc-based-applications
Unit-type cogeneration unit
When redesigning unit-type
cogeneration units, the
automation approach should
also be restructured. The
objective was to execute all
control, visualization and
archiving tasks which were
previously handled by a PLC
and a PC on a compact unit.
Space was to be saved in the
control cabinet, and the admin-
istration and training require-
ments reduced. At the same
time a rugged, maintenance-
free device was required which can also be easily connected
over the Internet.
The advantages of the solution with SIMATIC PC-based
Automation:
Microbox PC IPC427C as a rugged, compact embedded
system
- Control, visualization and archiving of the process param-
eters in one device
- Space and cost savings thanks to integration of several
tasks on a single embedded industrial PC
Previously: one PLC and one visualization PC
Easy and quick access to the embedded IPC over the Internet
The plant concept
Measurement of foil thickness
During the manufacture of
plastic films, a highly accurate
and uniform foil thickness over
the entire width is a decisive
quality criterion.
For this purpose, a measuring
head with radioactive source
moves back and forth above the
film and perpendicular to the
continuously transported reel,
and a sensor moves underneath
the foil.
From the attenuation of the radiation, the foil thickness can be
determined exactly at each position by extensive mathematical
calculations, and deviations from the reference thickness can be
compensated.
The advantages of the solution with SIMATIC PC-based
Automation:
Visualization is performed using WinCC, and control using
WinAC RTX on a PC.
Complex mathematical algorithms are required for evaluation
of the extensive measured data.
These are meaningfully implemented in the high-level
language C++. Seamless and high-performance integration
of these algorithms into the STEP 7 program is via the ODK
(Open Development Kit).
Data exchange between WinAC RTX and WinCC, for visual-
ization of the extensive measured curves, takes place very
quickly via the hard drive cache. This functionality was also
implemented via the ODK.
Interconnection of the standardized technology function is via
CFC (Continuous Function Chart).
The plant concept
Remote control
station
2 x ET 200S with
motor starter
Internet/
telephone network
E-mail
2 x ET 200S
DI/DO
Router
Embedded IPC
Microbox PC
IPC427
G_ST80_XX_00430
Industrial
Ethernet
Visual C++
Analysis of the
measured data
G_ST80_XX_00431
Drive
WinCC WinAC RTX
CP 5613 A2
ET 200M
SIMATIC HMI IPC577
PROFIBUS
ST80_2013_EN_Kap01.book Seite 9 Freitag, 2. August 2013 3:13 15
© Siemens AG 2013
Introduction
SIMATIC PC-based Automation
1/10 Siemens ST 80 / ST PC · 2013
Overview (continued)
1
PC-based control of paint shops for plastic automotive parts
For reasons of quality assurance
and product liability, paint shop
manufacturers are obliged to
use a host computer for
archiving the process data of a
paint shop for flat parts, but this
quickly developed into a PC-
based automation system with
control tasks.
The advantages of the solution with SIMATIC PC-based
Automation:
Performance of the SIMATIC WinAC PC-based control.
Coupling to Linux servers through an Industrial Ethernet fiber-
optic network.
Open and flexible for expansions.
Possibility of integration into the existing automation concept.
Archiving and backup of process data, as well as production
data acquisition.
The plant concept
Innovative PC-based solution with safety for solar panel
production
For a new plant for the
production of solar panels, the
existing highly heterogeneous
concept is to be replaced by a
new, state-of-the-art automation
solution which can cover the
comprehensive demands in a
compact and integrated way.
There are increased perfor-
mance and memory require-
ments due to the increased
complexity of the system. The
PLC should also be able to
provide the specified safety functions (emergency stop, access
protection to hazardous areas).
Various bus systems must be linked in plant 3. Also a customer-
specific Windows application is to be used on the selected
systems and therefore the connection to a higher-level MES
system has to be implemented.
The system is designed for high throughput and three-shift
operation.
The advantages of the solution with SIMATIC PC-based
Automation:
Very high performance and available memory with the
SIMATIC Modular Embedded Controller EC31-RTX F. In the
RTX F version (worldwide the first software PLC with safety
functionality), the EC31 offers full coverage of all safety
requirements in the plant. This system is integrated
seamlessly in Totally Integrated Automation and enables
effective, plant-wide engineering.
Thanks to its openness (Open Development Kit), WinAC RTX
on the host SCADA industrial PC offers the possibility for
integrating a Windows customer application with very little
effort, and is thus used as a data concentrator (process
quality/diagnostic data), and communication with the host
MES system is also implemented in combination with WinCC
(SCADA).
Industry-standard products from the SIMATIC range offer
maximum quality for 24/7 round the clock operation.
FOC Ethernet
Frequency
converter
Linux
Server
G_ST80_XX_00432
VS 710TP 177
HMI Panel
HMI
Panel
S7-314
S7-314
ET 200M
Rack PC IPC847
WinAC RTX
WinCC flexible
MPI DP
PROFIBUS DP
HMI Panel
ST80_2013_EN_Kap01.book Seite 10 Freitag, 2. August 2013 3:13 15
© Siemens AG 2013
Introduction
SIMATIC PC-based Automation
1/11
Siemens ST 80 / ST PC · 2013
Overview (continued)
Safe transfer at sea
For transferring persons at sea
to wind energy plants or oil
platforms, a Dutch company has
developed a six-legged
platform on hydraulic cylinders.
This platform is basically an
upside-down flight simulator,
and allows safe transfer from a
ship even in bad weather.
A SIMATIC S7 modular embedded controller (S7-mEC) with fast
I/O cards measures the movements of the ship and controls the
extending or retracting of the cylinders so that all movements are
compensated.
The advantages of the solution with SIMATIC PC-based
Automation:
Fault-tolerant SIMATIC S7-400H in redundant design for
general control tasks.
Two lower-level SIMATIC S7 modular embedded controllers
which meet the requirements for high speeds, integration of
fast I/O cards, and a flexible, modular and rugged design.
An integrated programming environment
with SIMATIC STEP 7.
Automation products from Siemens comply
with the stringent requirements of the offshore sector.
PC-based machine data acquisition optimizes the production
of farming machinery
To introduce more efficient,
resource-saving and therefore
cost-effective production
processes in the factory, a
leading farming machinery
manufacturer has integrated a
central, plant-wide machine
data acquisition system using
Panel PCs. Due to the need for
retrofitting in the existing
environment, flexible and
space-saving installation of the
Panel PCs was paramount.
More than 200 fully enclosed SIMATIC HMI IPC477C PRO Panel
PCs for central machine data acquisition with communications
interfacing to the production machines and the production
planning computer. Mounting of the Panel PCs directly at the
machine without additional control boxes on stand-alone
columns.
The advantages of the solution with SIMATIC PC-based
Automation:
Enhanced efficiency by optimizing the complete production
organization through a high degree of uniformity.
Minimized use of resources
(less paper is required in production).
Simple, low-cost retrofitting of the Panel PC directly in
production on a stand, without the installation of an additional
operator console.
ST80_2013_EN_Kap01.book Seite 11 Freitag, 2. August 2013 3:13 15
© Siemens AG 2013
Introduction
SIMATIC PC-based Automation
1/12 Siemens ST 80 / ST PC · 2013
Overview (continued)
1
PC-based control in automotive test rigs
Test rigs in the automotive
industry require trouble-free
operation and high quality.
A high-performance system is
required in the control,
processing, archiving and
visualization of measured data
which can also provide
openness and flexibility for
connection to different bus
systems and for the use of
software.
The advantages of the solution with SIMATIC PC-based
Automation:
Flexible, easy-to-service and maintenance-friendly
system with Windows XP Embedded in conjunction with
SIMATIC WinAC.
Reduction in integration overhead thanks to integral interfaces
such as PROFINET, PROFIBUS, Ethernet, CAN, and the flexi-
bility when using modules for different bus systems,
e.g. PC/104.
System availability concept ensures round-the-clock
operation and reduced downtime costs.
Fan-free, temperature-resistant operation up to 50°C saves
additional cooling measures.
High investment security through long-term availability of the
components.
The plant concept
PC-based control in the semiconductor industry
In the semiconductor industry, high quality and fault-free
operation round-the-clock are decisive criteria. A high-perfor-
mance system that guarantees fast and precise production of
the semiconductors is required for controlling the machines,
monitoring the production system, and processing the
production data.
High flexibility and openness are also required for connecting to
the production control system and machine engineering system.
The advantages of the solution with SIMATIC PC-based
Automation:
Compact, rugged industrial PCs with powerful processors
and the latest technology enable high processing perfor-
mance.
Pre-installed systems save time and costs when integrated
into the overall system.
WinCC ToolLink-EDA (equipment data acquisition) enables
diagnostics of process and machine data in real time.
System availability concept with integral RAID1 functionality
and remote monitoring with SIMATIC PC DiagMonitor ensures
fault-free 24-hour operation.
High investment security through long-term availability of the
components.
International certification and worldwide support guarantee
global use.
The plant concept
Sensors
Vehicle
control unit
Distributed
I/O devices
Label printer
Sensors
Distributed
I/O devices
Barcode
reader
Touch panel
G_ST80_XX_00433
USB Microbox
PC IPC427
RS232
Industrial Ethernet CAN-Bus
PROFIBUS DP
Machine
control
Visualization
Measuring and
control
instruments
Sensors
Port to
engineering
system
HUB
Host
G_ST80_XX_00434
Industrial Ethernet
SIMATIC
IPC627
SIMATIC
IPC627
HMI
Panel
Touch Panel
Industrial Ethernet
ST80_2013_EN_Kap01.book Seite 12 Freitag, 2. August 2013 3:13 15
© Siemens AG 2013
Introduction
SIMATIC PC-based Automation
1/13
Siemens ST 80 / ST PC · 2013
Overview (continued)
Track & trace line controller for tobacco industry
In order to comply with new
legal regulations, a track & trace
system in an existing plant has
been extended.
The requirement is to test
100 cartons per minute in
three-shift operation and to save
the data in an SQL database for
traceability reasons.
The automation system should
be characterized by high
ruggedness, but also offer the
openness required to connect
additional components such as printers and the Machine Vision
system.
The advantages of the solution with SIMATIC PC-based
Automation:
Compact automation solution consisting of embedded
industrial PC Microbox PC IPC427, PLC with preinstalled and
ready-to-use software PLC WinAC RTX, and visualization with
WinCC flexible.
Control of the entire track & trace system and interfacing to the
control system.
Open solution with the help of the WinAC ODK (Open Devel-
opment Kit) thanks to a link to an SQL database for managing
the serial numbers and other data.
Additional openness and flexibility by connecting printers and
vision system.
Retrofit of a woodworking machine – safe!
In the past, machines and plants
for wood-working were
equipped with specially
developed, proprietary
controllers. Today, future-
oriented standard components
are used for retrofit projects. The
customer decided in favor of
integrating standard automation
and safety technology in a
single unit with the SIMATIC
WinAC RTX F software controller
in a fan-free and maintenance-
free IPC, the SIMATIC IPC427C
Microbox PC. PROFINET as an innovative fieldbus connects
distributed I/O, safety and operator panels quickly and easily.
The advantages of the solution with SIMATIC PC-based
Automation:
The compact PC-based automation solution multiplies the
performance and precision of the plant.
Implementation of PROFINET resulted in a series of additional
advantages such as the diagnostics capability.
Integration of standard and fail-safe automation in a single unit
achieved component savings. The size of the cabinet was
reduced by 20 percent and the wiring by 50 percent. The
customer benefited from a high level of operating conve-
nience and minimized machine downtimes.
www.siemens.com/reference-video-kuper
ST80_2013_EN_Kap01.book Seite 13 Freitag, 2. August 2013 3:13 15
© Siemens AG 2013
Introduction
SIMATIC PC-based Automation
1/14 Siemens ST 80 / ST PC · 2013
Overview (continued)
1
Image processing with data backup
In image processing applications, high performance computers
are required due to the large volume of data to be processed.
The image data must be recorded, processed and saved
quickly. Frame grabber cards with a high data throughput, for
example, are used for recording image data. The interfaces for
the expansion cards must not become bottle-necks in this case.
To ensure continued problem-free processing of the acquired
data, you need a state-of-the-art system with up-to-date
processor and memory technology.
Lots of data is produced again during the subsequent data
backup. Thus the available storage medium must be fast and
fail-safe at the same time. An open system is required for
connecting to existing plants.
The advantages of the solution with SIMATIC PC-based
Automation:
Rugged SIMATIC PC with state-of-the-art processor perfor-
mance and the latest technology.
Current interfaces such as PCI Express for applications with a
high data throughput rate, e.g. frame grabber cards for
recording image data.
Visualization on up to two monitors with an optional,
high-performance graphics card.
Onboard communication interfaces such as Ethernet and
PROFINET, e.g. for connecting to EPS systems or integration
in existing systems.
International certifications and global support facilitate the
worldwide use of the image processing solution.
The plant concept
High-performance industrial PC for reliable control and
monitoring of wind power plants.
All Siemens turbines for offshore
wind power plants feature
special technical characteristics
that ensure long-term,
low-maintenance operation.
In contrast to sites on land,
offshore wind farms are not
always accessible to service
teams. The basic quality
requirements and standards for
all components used in terms of
absolute fail-safety and
reliability, are therefore
extremely high.
The SIMATIC Box PC of the 627 series that has been imple-
mented matches the requirements of the solution provider all the
way down the line. The rugged industrial PC is designed for
24-hour continuous duty at ambient temperatures up to 55 °C.
For reliable operation, the Box PC is installed in a solid metal
enclosure that is resistant to shock and vibration and that
demonstrates a high degree of of electromagnetic compatibility
(EMC). For a high level of data security, the option of a mirror disk
system with two hard disks (RAID1) was selected. The RAID1
controller is already onboard, and does not occupy a PCI slot.
The rugged, reliable hardware with extremely compact dimen-
sions in durable industrial design also stands up to the demands
of continuous operation in a harsh environment.
The advantages of the solution with SIMATIC PC-based
Automation:
The mounting dimensions of Box PCs remain identical over
several device generations and mounting solutions can be
simply reused for the next generation.
Furthermore, when a new device generation is used, any front-
accessible interfaces and function elements can be retained.
For example, the Siemens Wind division already utilized a
complete lifecycle of a Box PC generation and no adjustments
to a new hardware platform were required when the successor
product was introduced.
Through compliance with international standards, such as CE
and UL, and worldwide service, the Box PC can be imple-
mented round the globe.
.
.
.
Rack PC
IPC547 –
Server for data
management
Rack PC IPC547
for visualization and
intermediate storage
of data
Machine-level
Rack PC IPC847 with
PCIe frame grabber cards
Camera
Control room Server room
G_ST80_XX_00436
Industrial Ethernet
Flat Panel
ST80_2013_EN_Kap01.book Seite 14 Freitag, 2. August 2013 3:13 15
© Siemens AG 2013
Siemens ST 80 / ST PC · 2013
2
Operator panels
2/2 Introduction
2/6 Key Panels
2/6 SIMATIC HMI KP8/KP8F/32F
2/12 Basic Panels
2/12 Basic Panels – Standard
2/24 SIPLUS Basic Panels
2/26 Comfort Panels
2/26 Comfort Panels – Standard
2/40 SIPLUS Comfort Panels
2/44 Mobile Panels
2/45 SIMATIC Mobile Panel 177
2/52 SIMATIC Mobile Panel 277
2/57 SIMATIC Mobile Panel 277(F) IWLAN
2/69 System components for Mobile Panels
2/70 Terminal boxes
2/73 SIPLUS connection boxes
2/74 System components
2/74 Charging station
2/75 Transponder
2/76 System interfaces with WinCC
(TIA Portal)
2/77 SIMATIC S7
2/79 Controllers from other manufacturers
2/83 System interfaces with WinCC flexible
2/84 SIMATIC S7
2/87 SIMATIC S5
2/89 SIMATIC 505
2/90 PLCs from other manufacturers
2/96 SIMATIC HMI accessories
2/96 General HMI accessories
2/97 Industrial USB Hub 4
2/98 Touch pen and touch stylus
2/99 SIMATIC Mobile Panel accessories
2/100 Power supply unit
2/101 Additional accessories
2/104 SIMATIC HMI accessories
2/104 Connectors/converters/adapters
2/105 HMI connecting components
2/109 RS485 bus connector
2/110 IE FC RJ45 Plug 2 x 2
2/112 Connecting cables
2/116 Memory media
2/118 Service sets
2/122 Protective covers
2/124 Protective films
2/130 Fasteners
2/135 Labeling strips
2/137 Batteries
ST80_2013_EN_Kap02.book Seite 1 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Introduction
Introduction
2/2 Siemens ST 80 / ST PC · 2013
2
Overview
A finely graded range of HMI devices is available for local
operator control and monitoring: From Key Panels and Basic
Panels to Comfort Panels and Mobile Panels. HMI devices with
all-round IP65/NEMA 4 protection for distributed configurations
are available for applications with especially high requirements
with regard to ruggedness.
Key Panels
Key Panels (KP) are the innovative alternative to conventionally
wired operator keypads. Supplied pre-assembled and ready for
installation, the bus-compatible operator panels are the key to
drastically reducing wiring times when compared with conven-
tional methods.
Basic Panels
Basic Panels offer basic HMI functionality for small machines
and applications. They are available in 3" and 4" sizes as a pure
Key Panel (KP), from 4" to 10" with touch screen and additional
keys (KTP), and as a pure Touch Panel (TP) in size 15". Variants
can be selected for connection to PROFINET/Ethernet or
PROFIBUS DP/MPI.
Comfort Panels
Comfort Panels offer high-end functionality for demanding appli-
cations. They offer high-resolution widescreen displays in sizes
from 4" to 22", alternatively for touch screen operation (TP) or key
operation (KP). In size 4" also with touch screen and additional
keys (KTP).
The Comfort Panels are equipped with PROFINET/Ethernet as
well as PROFIBUS DP/MPI interfaces.
Mobile Panels
The portable operator panels facilitate operator control and
monitoring at the actual scene of the event with direct access
and visual contact to the process. They provide simple and safe
reconnection during operation (Mobile Panel 177 and Mobile
Panel 277) or wireless freedom (Mobile Panel 277 (F) IWLAN)
and can therefore be used flexibly on a machine or system.
Fast commissioning
Easy networking
Intuitive state detection
Brilliant widescreen displays from 4"... 22"
Innovative commissioning and service concept
Energy management with PROFIenergy
Highest demands in terms
of performance and functionality?
Intuitive operation of
3"... 15"
Integrated HMI basis
functionality
Perfect interaction with
SIMATIC S7-1200
Low priced, pixel graphics
operator prompting?
Innovative operation
with and without cable
Robust for site-related local
operation
Integrated safety
concept
Maximum mobility and
flexibility?
Flexible expansion with keys –
or even safety functions?
Basic
Panels
Key
Panels
Mobile
Panels
Comfort
Panels
E
n
g
i
n
e
e
r
e
d
w
i
t
h
T
o
t
a
l
l
y
I
n
t
e
g
r
a
t
e
d
A
u
t
o
m
a
t
i
o
n
P
o
r
t
a
l
G_ST80_XX_00501
ST80_2013_EN_Kap02.book Seite 2 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Introduction
Introduction
2/3
Siemens ST 80 / ST PC · 2013
Overview (continued)
2
Rugged and compact for use at machine level
With IP65/NEMA 4 degree of protection at the front, high EMC
and extreme vibration resistance, the SIMATIC HMI operator
panels are ideally suited for use at machine level in rough indus-
trial environments. Thanks to their compact design with a
shallow mounting depth, the stationary HMI devices can be
fitted anywhere, even where only restricted space is available.
For distributed configurations, there are also devices available
with all-round IP65/NEMA 4 protection.
The extremely rugged and shock-proof enclosure with degree of
protection IP65 makes the Mobile Panels especially suitable for
industrial applications. Their low weight and ergonomic design
means that they are user-friendly and easy to operate.
One configuration software for everything
SIMATIC WinCC (TIA Portal) is a tool for the uniform configu-
ration of all SIMATIC HMI Panels as well as PC-based systems.
Graded variants are available for every task. The software
permits simple and efficient configuration. Programming
experience is not required.
Once created, configurations can be reused within the family.
Component of Totally Integrated Automation
Siemens provides the complete modular system of matched
components for automation solutions from one source and —
with Totally Integrated Automation — one of the most globally
successful automation concepts. SIMATIC WinCC (TIA Portal) is
an integral component of this world. It offers crucial advantages.
Thanks to the triple uniformity in configuration/programming,
data management and communication, automation solution
engineering costs are significantly reduced.
Open for a wide variety of automation systems
Despite being consistently incorporated into the SIMATIC world,
the Panels are nevertheless open for connection to PLCs from
many different vendors. The standard delivery includes a
comprehensive range of user-friendly drivers.
Innovative operator control and monitoring
The SIMATIC HMI Panels facilitate innovative operator control
and monitoring combined with ruggedness, stability and
simplicity. On the Comfort Panels in particular, standard
hardware and software interfaces, e.g. the Multimedia Card/
SD Card, USB, Ethernet, PROFIBUS DP and Visual Basic
scripts, provide more flexibility and openness as well as access
to the office world.
Worldwide application
The SIMATIC HMI Panels are ideally equipped for global use.
Online language switching permits selection of up to
32 languages during operation simply by pressing a button.
The wide variety available also includes, for example, Asian
logographic languages (Chinese, Taiwanese, Korean,
Japanese) or Russian. The configuration interface of WinCC
(TIA Portal) including the online help and the complete
documentation is also multilingual. Up to 32 languages can be
used in one project. And all this is complemented by global
service and support from Siemens.
ST80_2013_EN_Kap02.book Seite 3 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Introduction
Introduction
2/4 Siemens ST 80 / ST PC · 2013
Overview (continued)
2
Configuration at a Glance
• Possible
1) from WinCC (TIA Portal) V11 SP1
2) from WinCC (TIA Portal) V11 SP2 Update 2
3) from WinCC (TIA Portal) V11 SP2
WinCC (TIA Portal) engineering software
Basic Comfort Advanced Professional
Basic Panels
KP300 Basic • •
KTP400 Basic mono PN • •
KTP400/KP400 Basic color PN 2) 2) 2) 2)
KTP600 Basic • •
KTP1000 Basic • •
TP1500 Basic • •
Comfort Panels
KTP400/KP400 Comfort • •
TP700/KP700 Comfort • •
TP900/KP900 Comfort • •
TP1200/KP1200 Comfort • •
TP1500/KP1500 Comfort 2) 2) 2)
TP1900 Comfort 2) 2) 2)
TP2200 Comfort 2) 2) 2)
Mobile Panels
Mobile Panel 177 • •
Mobile Panel 277 • •
Mobile Panel 277(F) IWLAN 3) 3) 3)
Panels – 70 series
OP73 • •
OP77A • •
OP77B • •
Panels – 170 series
TP 177A • •
TP/OP 177B • •
Panels – 270 series
TP 277/OP 277 • •
Multi Panels – 170 series
MP 177 • •
Multi Panels – 270 series
MP 277 • •
Multi Panels – 370 series
MP 377 • •
WinAC MP
WinAC MP 177 1) 1) 1)
WinAC MP 277 1) 1) 1)
WinAC MP 377 1) 1) 1)
ST80_2013_EN_Kap02.book Seite 4 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Introduction
Introduction
2/5
Siemens ST 80 / ST PC · 2013
Overview (continued)
2
• Possible
1) WinCC flexible 2005 or higher and TP 177B 4" with WinCC flexible 2008 and higher
2) WinCC flexible 2005 SP1 and higher
3) WinCC flexible 2007 and higher: Mobile Panel 277(F) IWLAN V1; WinCC flexible 2008 SP2 and higher: Mobile Panel 277(F) IWLAN V2
4) WinCC flexible 2008 and higher
5) WinCC flexible 2008 SP1 and higher
WinCC flexible engineering software
Micro Compact Standard Advanced
Basic Panels
KTP400 Basic mono PN 5) 5) 5)
KTP600 Basic 5) 5) 5)
KTP1000 Basic 4) 4) 4)
TP1500 Basic 4) 4) 4)
Mobile Panels
Mobile Panel 177 1) 1) 1)
Mobile Panel 277 2) 4) 2) 4)
Mobile Panel 277(F) IWLAN 3) 3)
Micro Panels
OP 73micro • •
TP 177micro • •
Panels – 70 series
OP 73 • •
OP 77A/B • •
Panels – 170 series
TP 177A • •
TP/OP 177B 1) 1) 1)
Panels – 270 series
TP 277/OP 277 2) 2)
Multi Panels – 170 series
MP 177 5) 4) 4)
Multi Panels – 270 series
MP 277 • •
Multi Panels – 370 series
MP 377 3) 3)
WinAC MP
WinAC MP 177 5) 5) 5)
WinAC MP 277 5) 5)
WinAC MP 377 5) 5)
ST80_2013_EN_Kap02.book Seite 5 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Key Panels
SIMATIC HMI KP8/KP8F/32F
2/6 Siemens ST 80 / ST PC · 2013
2
Overview
SIMATIC HMI KP32F and HMI KP8
Empty front (similar to figure)
Empty front (similar to figure)
SIMATIC HMI Key Panels
Optimum operability thanks to large mechanical keys and
multi-colored LED backlighting (daylight readable)
Over 60% time savings for wiring and installation (Plug&Play)
More than 30% savings in material costs compared to conven-
tional keypad operator panels
2 PROFINET ports (incl. switch) already integrated for setting
up line and ring topologies
Freely configurable digital I/Os on the rear for connecting
key-operated switches, indicator lamps, etc.
Connection of fail-safe emergency stop buttons or other
fail-safe signals with KP8F and KP32F (in SIL2 or SIL3)
Functionally compatible with all standard PROFINET master
CPUs, also non-Siemens
KP8 and empty front design, also optimized for installation in
IPC Extension Units in IP65
Maximum flexibility due to parameterization
Empty front design for standardized assembly of flexible
operator panels
KP8 and empty front design, also optimized for installation in
IPC Extension Units in IP65
ST80_2013_EN_Kap02.book Seite 6 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Key Panels
SIMATIC HMI KP8/KP8F/32F
2/7
Siemens ST 80 / ST PC · 2013
2
Technical specifications
6AV3688-3AY36-0AX0 6AV3688-3AF37-0AX0 6AV3688-3EH47-0AX0 6AV3688-3XY38-3AX0
SIMATIC HMI KP8 PN SIMATIC HMI KP8F PN SIMATIC HMI KP32F PN SIMATIC HMI
design empty front
Control elements
With parameterizable keys Yes Yes Yes No
With key and signal lamp test Yes; Automatically when
switching on Yes; Automatically when
switching on Yes; Automatically when
switching on No
Keyboard fonts
freely inscribable membrane keys Yes Yes Yes No
Short stroke keys
- Number of short-stroke keys 8 8 32 0
Expansions for operator control
of the process
•Number/LEDs 8 8 32 0
Number of color modes for LED 5; Red, green, blue, white,
yellow 5; Red, green, blue, white,
yellow 5; Red, green, blue, white,
yellow 0
•Number/keys 8 8 32 0
Installation type/mounting
Rack mounting possible No No No No
Design/front/fastening Yes; Compatible with
extension unit dimensions Yes; Compatible with
extension unit dimensions Yes Yes; Compatible with
extension unit dimensions
Mounting rail installation possible No No No No
Wall mounting/direct mounting possi-
ble No No No No
Mounting in portrait format possible Yes Yes Yes Yes
Mounting in landscape format
possible Yes Yes Yes Yes
Mounting technology
Clamp terminals Yes Yes Yes Yes
Number of slots for command
devices and signaling units 0 0 0 5; Max. 5 possible
Supply voltage
Type of supply voltage DC DC DC external
Rated voltage/DC 24 V 24 V 24 V
permissible range, lower limit (DC) 20.4 V 20.4 V 20.4 V
permissible range, upper limit (DC) 28.8 V 28.8 V 28.8 V
Type of output
LED colors
•Red Yes Yes Yes No
• Yellow Yes Yes Yes No
•Green Yes Yes Yes No
•white Yes Yes Yes No
•blue Yes Yes Yes No
Digital inputs
Number/binary inputs 8; Max. 8 inputs and
outputs (total) 8; Max. 32 inputs and
outputs (total) 32; Max. 32 inputs and
outputs (total) 0
Digital outputs
Number/binary outputs 8; Max. 8 inputs and out-
puts (total) 8; Max. 8 inputs and out-
puts (total) 16; Max. 32 inputs and
outputs (total) 0
Load "resistive" 100 mA 100 mA 100 mA
Voltage (DC) 24 V; Non-isolated 24 V; Non-isolated 24 V; Non-isolated
Number of digital outputs
Output current (per output) max. 100 mA 100 mA 100 mA
Total current (per group), max. 800 mA 800 mA 800 mA
Short-circuit protection Yes Yes Yes No
ST80_2013_EN_Kap02.book Seite 7 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Key Panels
SIMATIC HMI KP8/KP8F/32F
2/8 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
Interfaces
Supports protocol for PROFINET IO
Number of PROFINET interfaces 2; Incl. switch 2; Incl. switch 2; Incl. switch 0
Industrial Ethernet
Number of industrial Ethernet
interfaces 2; For the construction of
lines and rings without
external switch
2; For the construction of
lines and rings without
external switch
2; For the construction of
lines and rings without
external switch
0
Industrial Ethernet status LED 2; Per port 2; Per port 2; Per port 0
Number of ports of the integrated
switch 2; Per port 2; Per port 2; Per port 0
Protocols
PROFINET Yes; Incl. shared device Yes; Incl. shared device Yes; Incl. shared device No
Supports protocol for PROFINET IO Yes Yes Yes No
IRT supported Yes Yes Yes No
MRP supported Yes Yes Yes No
PROFINET CBA No No No No
Supports protocol for PROFIsafe No Yes; Mode V2.0; 2 inputs
can be used Yes; Mode V2.0; 4 inputs
can be used No
PROFIBUS No No No No
Test commissioning functions
Illuminant test Yes; During switch on Yes; During switch on Yes; During switch on No
Pushbutton and lamp test Yes; During switch on Yes; During switch on Yes; During switch on No
EMC
Emission of radio interference
acc. to EN 55 011
Emission of radio interferences
acc. to EN 55 011 (limit class A) Yes; Group 1, measured
at a distance of 10 m Yes; Group 1, measured
at a distance of 10 m Yes; Group 1, measured
at a distance of 10 m No
Emission of radio interference
acc. to EN 55 011 (limit class B) No No No No
Degree and class of protection
Type of protection IP20 IP20 IP20 IP20
IP (at the front) IP65 IP65 IP65 IP65
Enclosure type 4x at the front Yes; Incl. NEMA12 Yes; Incl. NEMA12 Yes; Incl. NEMA12 No
Standards, approvals, certificates
CE Yes Yes Yes Yes
KC approval Yes Yes Yes No
cULus Yes Yes Yes No
C-TICK Yes Yes Yes No
GL No No No No
ABS No No No No
BV No No No No
DNV No No No No
LRS No No No No
Class NK No No No No
PRS No No No No
Suitable for safety functions No Yes Yes Yes; e.g. installation of
emergency stop
Use in hazardous areas
ATEX Zone 2 Yes Yes No; On request No
ATEX Zone 22 Yes Yes No; On request No
cULus Class I Zone 1 No No No No
cULus Class I Zone 2,
Division 2 Yes Yes Yes No
FM Class I Division 2 Yes Yes; Available soon Yes No
6AV3688-3AY36-0AX0 6AV3688-3AF37-0AX0 6AV3688-3EH47-0AX0 6AV3688-3XY38-3AX0
SIMATIC HMI KP8 PN SIMATIC HMI KP8F PN SIMATIC HMI KP32F PN SIMATIC HMI
design empty front
ST80_2013_EN_Kap02.book Seite 8 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Key Panels
SIMATIC HMI KP8/KP8F/32F
2/9
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
Ambient conditions
Mounting position vertical vertical vertical Any
maximum permissible angle of
inclination without external ventilation 30°; To the front/rear 30°; To the front/rear 30°; To the front/rear 180°; To the front/rear
Operating temperature
Operating temperature range, max. 55 °C 55 °C 55 °C 55 °C
Operating temperature range, min. C 0°C C 0°C
Operation (vertical installation)
- in vertical mounting position/
minimum C 0°C 0°C 0°C
- in vertical mounting position/
maximum 55 °C 55 °C 55 °C 55 °C
Operation (max. tilt angle)
- at maximum tilt angle/
minimum C 0°C 0°C 0°C
- at maximum tilt angle/
maximum 45 °C 45 °C 45 °C 45 °C
Operation (vertical installation,
portrait format)
- in vertical mounting position/
minimum C 0°C 0°C 0°C
- in vertical mounting position/
maximum 45 °C 45 °C 45 °C 45 °C
Operation (max. tilt angle,
portrait format)
- at maximum tilt angle/
minimum C 0°C 0°C 0°C
- at maximum tilt angle/
maximum 45 °C 45 °C 45 °C 45 °C
Storage/transport temperature
•Min. -20 °C -20 °C -20 °C -20 °C
•max. 60 °C 60 °C 60 °C 60 °C
Relative humidity
max. relative humidity 95 % 95 % 95 % 95 %
Configuration
Configuration software
STEP 7 Basic (TIA Portal) Yes Yes Yes No
STEP 7 Professional
(TIA Portal) Yes Yes Yes No
Functionality under
WinCC (TIA Portal)
Process coupling
• S7-1200 Yes Yes Yes Yes
• S7-1500 Yes Yes Yes Yes
• S7-200 No No No No
• S7-300/400 Yes Yes Yes Yes
• LOGO! No No No No
•Win AC Yes Yes Yes Yes
• SINUMERIK No No No No
• SIMOTION No No No No
Allen Bradley (EtherNet/IP) No No No No
Allen Bradley (DF1) No No No No
• Mitsubishi (MC TCP/IP) No No No No
• Mitsubishi (FX) No No No No
OMRON (FINS TCP) No No No No
OMRON (LINK/Multilink) No No No No
Modicon (Modbus TCP/IP) No No No No
Modicon (Modbus) No No No No
6AV3688-3AY36-0AX0 6AV3688-3AF37-0AX0 6AV3688-3EH47-0AX0 6AV3688-3XY38-3AX0
SIMATIC HMI KP8 PN SIMATIC HMI KP8F PN SIMATIC HMI KP32F PN SIMATIC HMI
design empty front
ST80_2013_EN_Kap02.book Seite 9 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Key Panels
SIMATIC HMI KP8/KP8F/32F
2/10 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
Ordering data Order No. Order No.
Mechanics/material
Type of housing (front)
• Plastic Yes Yes No No
•Aluminum No No Yes Yes
Lifetime, typ.
Short-stroke keys
(in switching cycles) 1500000 1500000 1500000
Dimensions
Width of the housing front 98 mm 98 mm 295 mm 98 mm
Height of housing front 155 mm 155 mm 155 mm 155 mm
Mounting cutout (W x H x D)
Mounting cutout, width 68 mm; Max. thickness of
mounting plate 2-6 mm 68 mm; Max. thickness of
mounting plate 2-6 mm 277 mm; Max. thickness of
mounting plate 2-6 mm 68 mm; Max. thickness of
mounting plate 2-6 mm
Mounting cutout, height 129 mm 129 mm 137 mm 129 mm
Depth/installation dimension 49 mm; Incl. angled
SIMATIC Ethernet
connector
49 mm; Incl. angled
SIMATIC Ethernet
connector
69 mm; Incl. angled
SIMATIC Ethernet
connector
49 mm
Weight
Weight without packaging 270 g 280 g 1220g 240 g
6AV3688-3AY36-0AX0 6AV3688-3AF37-0AX0 6AV3688-3EH47-0AX0 6AV3688-3XY38-3AX0
SIMATIC HMI KP8 PN SIMATIC HMI KP8F PN SIMATIC HMI KP32F PN SIMATIC HMI
design empty front
SIMATIC HMI KP8 PN 6AV3688-3AY36-0AX0
Key Panel, 8 short-stroke keys with
multicolored LEDs, PROFINET inter-
faces, 2 x parameterizable with
STEP 7 V5.5 or higher
SIMATIC HMI KP8F PN 6AV3688-3AF37-0AX0
Key Panel, 8 short-stroke keys with
multicolored LEDs, PROFINET inter-
faces with PROFIsafe, parameteriz-
able with STEP 7 V5.5 or higher;
4 additional fail-safe inputs. Can be
used as 2 x SIL 2 or 1 x SIL 3
SIMATIC HMI KP32F PN 6AV3688-3EH47-0AX0
Key Panel, 32 short-stroke keys with
multicolored LEDs, PROFINET inter-
faces with PROFIsafe, parameteriz-
able with STEP 7 V5.5 or higher;
including 8 fail-safe inputs. Can be
used as 4 x SIL 2 or 2 x SIL 3
Empty front design 6AV3688-3XY38-3AX0
for standard 22.5 mm operator
controls, same mounting
dimensions as KP8
Demo case A5E31477788
SIMATIC HMI Key Panel – low-cost
demo and experiment case Only by fax to
Siemens AG,
Mr. Michael Christ
Industry Sector,
I IA CE SE MF RS FDS
Wuerzburger Str. 121,
90766 Fuerth, Germany
Tel.: +49 911 750-4128
Fax: +49 911 750-2411
• Includes:
- 1x case
- 1x KP8 PN
- 1x CPU1211C
- 1x stand, permanently wired,
including program
Power supply possible with a
standard laptop mains adapter
(not included in scope of supply)
Documentation
You can find the manual for
the Key Panels on the Internet at: http://support.automation.sie-
mens.com/WW/view/en/56652789
Accessories See SIMATIC HMI accessories,
from page 2/96
ST80_2013_EN_Kap02.book Seite 10 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Key Panels
SIMATIC HMI KP8/KP8F/32F
2/11
Siemens ST 80 / ST PC · 2013
2
Dimensional drawings
All dimensions in mm. For installation cutout, see technical
specifications.
SIMATIC HMI Key Panel KP8; installation dimensions also valid for empty
front design
SIMATIC HMI Key Panel KP32F
More information
Additional information is available on the Internet at:
http://www.siemens.com/simatic-key-panels
Note:
Do you need a specific modification or extension to the products
described here? If so, refer to "Customized Automation". There
you will find information about additional and generally available
sector-specific products as well as options for customer-specific
modification and adaptation.
Demo case
Can be ordered by fax:
Siemens AG, Mr. Michael Christ
Industry Sector, I IA CE SE MF RS FDS
Wuerzburger Str. 121, 90766 Fuerth, Germany
Phone: +49 911 750-4128
Fax: +49 911 750-2411
127.7
13.7
48.8
67.5 16.2
G_ST80_XX_00442
98
155
6
38
G_ST80_XX_00499
10
275
295
155
10 2 637
135
ST80_2013_EN_Kap02.book Seite 11 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Basic Panels
Basic Panels – Standard
2/12 Siemens ST 80 / ST PC · 2013
2
Overview
Ideal entry-level series from 3" to 15" for operating and
monitoring compact machines and systems
Clear process representation thanks to use of pixel-graphics
displays
Intuitive operation using Touch and tactile function keys
Equipped with all the necessary basic functions such as alarm
logging, recipe management, plots, vector graphics, and
language switching
Simple connection to the controller via integral Ethernet
interface or separate version with RS 485/422
Faster commissioning thanks to integrated diagnostics viewer
and IP setting for SIMATIC S7-1200 and S7-1500 PLCs
Technical specifications
6AV6647-0AA11-3AX0 6AV6647-0AK11-3AX0 6AV6647-0AB11-3AX0 6AV6647-0AC11-3AX0
SIMATIC HMI KTP400
Basic mono PN SIMATIC HMI KTP400
Basic color PN SIMATIC HMI KTP600
Basic mono PN SIMATIC HMI KTP600
Basic color DP
Display
Design of display STN TFT STN TFT
Screen diagonal 3.8 in 4.3 in 5.7 in 5.7 in
Number of colors 4; Grayscales 256 4; Grayscales 256
Resolution (pixels)
Horizontal image resolution 320 480 320 320
Vertical image resolution 240 272 240 240
Backlighting
MTBF backlighting (at 25 °C) 30 000 h 50 000 h 50 000 h 50 000 h
Dimmable backlight No No No No
Control elements
Keyboard fonts
Number of function keys 4 4 6 6
Touch operation
Design as touch screen Yes Yes Yes Yes
Installation type/mounting
Mounting in portrait format
possible Yes Yes Yes Yes
Supply voltage
Type of supply voltage DC DC DC DC
Rated voltage/DC 24 V 24 V 24 V 24 V
Memory
Usable memory for user data 1Mbyte 1Mbyte 1Mbyte 1Mbyte
Type of output
Acoustics
• Buzzer Yes Yes Yes Yes
Time of day
Clock
Software clock Yes Yes Yes Yes
• Battery-backed No No No No
• Synchronizable Yes Yes Yes Yes
Interfaces
Number of RS 485 interfaces 0 0 0 1
Number of USB interfaces 0 0 0 0
Number of SD card slots 0 0 0 0
Industrial Ethernet
Number of industrial Ethernet
interfaces 1 1 1 0
ST80_2013_EN_Kap02.book Seite 12 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Basic Panels
Basic Panels – Standard
2/13
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
Protocols
PROFINET Yes Yes Yes No
PROFIBUS No No No Yes
MPI No No No Yes
Degree and class of
protection
Type of protection IP20 IP20 IP20 IP20
IP (at the front) IP65 IP65 IP65 IP65
Enclosure type 4x at the front Yes Yes Yes Yes
Standards, approvals,
certificates
CE Yes Yes Yes Yes
cULus Yes Yes Yes Yes
GL Yes Yes Yes Yes
ABS Yes Yes Yes Yes
BV Yes Yes Yes Yes
DNV Yes Yes Yes Yes
LRS Yes Yes Yes Yes
Class NK Yes Yes Yes Yes
Use in hazardous areas
ATEX Zone 2 No No No No
ATEX Zone 22 No No No No
cULus Class I Zone 2,
Division 2 No No No No
FM Class I Division 2 No No No No
Ambient conditions
Operating temperature
Operation (vertical
installation)
- in vertical mounting
position/ minimum C 0°C C 0°C
- in vertical mounting
position/ maximum 50 °C 50 °C 50 °C 50 °C
Relative humidity
max. relative humidity 90 % 90 % 90 % 90 %
Configuration
Configuration software
STEP 7 Basic (TIA Portal) Yes; via integrated WinCC
Basic (TIA Portal) Yes; via integrated WinCC
Basic (TIA Portal) Yes; via integrated WinCC
Basic (TIA Portal) Yes; via integrated WinCC
Basic (TIA Portal)
WinCC flexible Compact Yes No Yes Yes
• WinCC Basic (TIA Portal) Yes Yes Yes Yes
Languages
Online languages
Number of online/runtime
languages 5 5 5 5
Functionality under WinCC
(TIA Portal)
Task planner
• time-controlled No No No No
• task-controlled Yes Yes Yes Yes
With alarm logging system (incl.
buffer and acknowledgment)
Number of bit messages 200 200 200 200
Number of analog messages 15 15 15 15
•Message buffer
- Number of entries 256 256 256 256
- Circulating buffer Yes Yes Yes Yes
- retentive Yes Yes Yes Yes
Recipes
Number of recipes 5 5 5 5
Size of internal recipe memory 40 kbyte 40 kbyte 40 kbyte 40 kbyte
Recipe memory expandable No No No No
6AV6647-0AA11-3AX0 6AV6647-0AK11-3AX0 6AV6647-0AB11-3AX0 6AV6647-0AC11-3AX0
SIMATIC HMI KTP400
Basic mono PN SIMATIC HMI KTP400
Basic color PN SIMATIC HMI KTP600
Basic mono PN SIMATIC HMI KTP600
Basic color DP
ST80_2013_EN_Kap02.book Seite 13 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Basic Panels
Basic Panels – Standard
2/14 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
Variables
Number of variables per
device 250 500 500 500
Number of variables per
screen 30 30 30 30
Images
Number of configurable
images 50 50 50 50
Archiving
Number of archives per
device 0 0 0 0
Security
Number of user groups 50 50 50 50
Number of users 50 50 50 50
Transfer (upload/download)
MPI/PROFIBUS DP No No No Yes
•Ethernet Yes Yes Yes No
Process coupling
• S7-1200 Yes Yes Yes Yes
• S7-1500 Yes Yes Yes Yes
• S7-200 Yes Yes Yes Yes
• S7-300/400 Yes Yes Yes Yes
• LOGO! Yes Yes Yes Yes
•Win AC Yes No Yes Yes
• SIMOTION No No No No
Allen Bradley (EtherNet/IP) Yes Yes Yes No
Allen Bradley (DF1) No No No Yes
• Mitsubishi (MC TCP/IP) Yes Yes Yes No
• Mitsubishi (FX) No No No Yes
OMRON (FINS TCP) No No No No
OMRON (LINK/Multilink) No No No Yes
Modicon (Modbus TCP/IP) Yes Yes Yes No
Modicon (Modbus) No No No Yes
I/O
I/O devices
•Printer No No No No
Multi Media Card No No No No
•SD card No No No No
USB memory No No No No
Mechanics/material
Type of housing (front)
• Plastic Yes Yes Yes Yes
Dimensions
Width of the housing front 140 mm 140 mm 214 mm 214 mm
Height of housing front 116 mm 116 mm 158 mm 158 mm
Mounting cutout (W x H x D)
Mounting cutout, width 123 mm 123 mm 197 mm 197 mm
Mounting cutout, height 99 mm 99 mm 141 mm 141 mm
Weight
Weight without packaging 0.32 kg 0.34 kg 1.07 kg 1.07 kg
6AV6647-0AA11-3AX0 6AV6647-0AK11-3AX0 6AV6647-0AB11-3AX0 6AV6647-0AC11-3AX0
SIMATIC HMI KTP400
Basic mono PN SIMATIC HMI KTP400
Basic color PN SIMATIC HMI KTP600
Basic mono PN SIMATIC HMI KTP600
Basic color DP
ST80_2013_EN_Kap02.book Seite 14 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Basic Panels
Basic Panels – Standard
2/15
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
6AV6647-0AD11-3AX0 6AV6647-0AE11-3AX0 6AV6647-0AF11-3AX0
SIMATIC HMI KTP600
Basic color PN SIMATIC HMI KTP1000
Basic color DP SIMATIC HMI KTP1000
Basic color PN
Display
Design of display TFT TFT TFT
Screen diagonal 5.7 in 10.4 in 10.4 in
Number of colors 256 256 256
Resolution (pixels)
Horizontal image resolution 320 640 640
Vertical image resolution 240 480 480
Backlighting
MTBF backlighting (at 25 °C) 50 000 h 50 000 h 50 000 h
Dimmable backlight No No No
Control elements
Keyboard fonts
Number of function keys 6 8 8
Touch operation
Design as touch screen Yes Yes Yes
Installation type/mounting
Mounting in portrait format possible Yes No No
Supply voltage
Type of supply voltage DC DC DC
Rated voltage/DC 24 V 24 V 24 V
Memory
Usable memory for user data 1Mbyte 2Mbyte 2Mbyte
Type of output
Acoustics
• Buzzer Yes Yes Yes
Time of day
Clock
Software clock Yes Yes Yes
• Battery-backed No No No
• Synchronizable Yes Yes Yes
Interfaces
Number of RS 485 interfaces 0 1 0
Number of USB interfaces 0 0 0
Number of SD card slots 0 0 0
Industrial Ethernet
Number of industrial Ethernet
interfaces 1 0 1
Protocols
PROFINET Yes No Yes
PROFIBUS No Yes No
MPI No Yes No
Degree and class of protection
Type of protection IP20 IP20 IP20
IP (at the front) IP65 IP65 IP65
Enclosure type 4x at the front Yes Yes Yes
Standards, approvals, certificates
CE Yes Yes Yes
cULus Yes Yes Yes
GL Yes Yes Yes
ABS Yes Yes Yes
BV Yes Yes Yes
DNV Yes Yes Yes
LRS Yes Yes Yes
Class NK Yes Yes Yes
ST80_2013_EN_Kap02.book Seite 15 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Basic Panels
Basic Panels – Standard
2/16 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
Use in hazardous areas
ATEX Zone 2 No No No
ATEX Zone 22 No No No
cULus Class I Zone 2, Division 2 No No No
FM Class I Division 2 No No No
Ambient conditions
Operating temperature
Operation (vertical installation)
- in vertical mounting position/
minimum C C 0°C
- in vertical mounting position/
maximum 50 °C 50 °C 50 °C
Relative humidity
max. relative humidity 90 % 90 % 90 %
Configuration
Configuration software
STEP 7 Basic (TIA Portal) Yes; via integrated WinCC Basic
(TIA Portal) Yes; via integrated WinCC Basic
(TIA Portal) Yes; via integrated WinCC Basic
(TIA Portal)
WinCC flexible Compact Yes Yes Yes
• WinCC Basic (TIA Portal) Yes Yes Yes
Languages
Online languages
Number of online/runtime languages 5 5 5
Functionality under WinCC
(TIA Portal)
Task planner
• time-controlled No No No
• task-controlled Yes Yes Yes
With alarm logging system
(incl. buffer and acknowledgment)
Number of bit messages 200 200 200
Number of analog messages 15 15 15
•Message buffer
- Number of entries 256 256 256
- Circulating buffer Yes Yes Yes
- retentive Yes Yes Yes
Recipes
Number of recipes 5 5 5
Size of internal recipe memory 40 kbyte 40 kbyte 40 kbyte
Recipe memory expandable No No No
Variables
Number of variables per device 500 500 500
Number of variables per screen 30 30 30
Images
Number of configurable images 50 50 50
Archiving
Number of archives per device 0 0 0
Security
Number of user groups 50 50 50
Number of users 50 50 50
Transfer (upload/download)
MPI/PROFIBUS DP No Yes No
•Ethernet Yes No Yes
6AV6647-0AD11-3AX0 6AV6647-0AE11-3AX0 6AV6647-0AF11-3AX0
SIMATIC HMI KTP600
Basic color PN SIMATIC HMI KTP1000
Basic color DP SIMATIC HMI KTP1000
Basic color PN
ST80_2013_EN_Kap02.book Seite 16 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Basic Panels
Basic Panels – Standard
2/17
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
Process coupling
• S7-1200 Yes Yes Yes
• S7-1500 Yes Yes Yes
• S7-200 Yes Yes Yes
• S7-300/400 Yes Yes Yes
• LOGO! Yes Yes Yes
•Win AC Yes Yes Yes
• SIMOTION No No No
Allen Bradley (EtherNet/IP) Yes No Yes
Allen Bradley (DF1) No Yes No
• Mitsubishi (MC TCP/IP) Yes No Yes
• Mitsubishi (FX) No Yes No
OMRON (FINS TCP) No No No
OMRON (LINK/Multilink) No Yes No
Modicon (Modbus TCP/IP) Yes No Yes
Modicon (Modbus) No Yes Yes
I/O
I/O devices
•Printer No No No
Multi Media Card No No No
•SD card No No No
USB memory No No No
Mechanics/material
Type of housing (front)
• Plastic Yes Yes Yes
Dimensions
Width of the housing front 214 mm 335 mm 335 mm
Height of housing front 158 mm 275 mm 275 mm
Mounting cutout (W x H x D)
Mounting cutout, width 197 mm 310 mm 310 mm
Mounting cutout, height 141 mm 248 mm 248 mm
Weight
Weight without packaging 1.07 kg 2.65 kg 2.65 kg
6AV6647-0AD11-3AX0 6AV6647-0AE11-3AX0 6AV6647-0AF11-3AX0
SIMATIC HMI KTP600
Basic color PN SIMATIC HMI KTP1000
Basic color DP SIMATIC HMI KTP1000
Basic color PN
ST80_2013_EN_Kap02.book Seite 17 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Basic Panels
Basic Panels – Standard
2/18 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
6AV6647-0AH11-3AX0 6AV6647-0AJ11-3AX0 6AV6647-0AG11-3AX0
SIMATIC HMI KP300
Basic mono PN SIMATIC HMI KP400
Basic color PN SIMATIC HMI TP1500
Basic color PN
Display
Design of display FSTN TFT TFT
Screen diagonal 3.6 in 4.3 in 15 in
Number of colors 4; Backlit display only
(white, red, green, yellow) 256 256
Resolution (pixels)
Horizontal image resolution 240 480 1024
Vertical image resolution 80 272 768
Backlighting
MTBF backlighting (at 25 °C) 50 000 h 50 000 h 50 000 h
Dimmable backlight No No No
Control elements
Keyboard fonts
Number of function keys 10 8 0
Touch operation
Design as touch screen No No Yes
Installation type/mounting
Mounting in portrait format possible No No No
Supply voltage
Type of supply voltage DC DC DC
Rated voltage/DC 24 V 24 V 24 V
Memory
Usable memory for user data 1Mbyte 1Mbyte 2Mbyte
Type of output
Acoustics
• Buzzer No No Yes
Time of day
Clock
Software clock Yes Yes Yes
• Battery-backed No No No
• Synchronizable Yes Yes Yes
Interfaces
Number of RS 485 interfaces 0 0 0
Number of USB interfaces 0 0 0
Number of SD card slots 0 0 0
Industrial Ethernet
Number of industrial Ethernet
interfaces 1 1 1
Protocols
PROFINET Yes Yes Yes
PROFIBUS No No No
MPI No No No
Degree and class of protection
Type of protection IP20 IP20 IP20
IP (at the front) IP65 IP65 IP65
Enclosure type 4x at the front Yes Yes Yes
Standards, approvals, certificates
CE Yes Yes Yes
cULus Yes Yes Yes
GL Yes No No
ABS Yes No No
BV Yes No No
DNV Yes No No
LRS Yes No No
Class NK Yes No No
ST80_2013_EN_Kap02.book Seite 18 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Basic Panels
Basic Panels – Standard
2/19
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
Use in hazardous areas
ATEX Zone 2 No No No
ATEX Zone 22 No No No
cULus Class I Zone 2, Division 2 Yes No No
FM Class I Division 2 No No No
Ambient conditions
Operating temperature
Operation (vertical installation)
- in vertical mounting position/
minimum C C 0°C
- in vertical mounting position/
maximum 50 °C 50 °C 50 °C
Relative humidity
max. relative humidity 90 % 90 % 90 %
Configuration
Configuration software
STEP 7 Basic (TIA Portal) Yes; via integrated WinCC Basic
(TIA Portal) Yes; via integrated WinCC Basic
(TIA Portal) Yes; via integrated WinCC Basic
(TIA Portal)
WinCC flexible Compact No No Yes
• WinCC Basic (TIA Portal) Yes Yes Yes
Languages
Online languages
Number of online/runtime languages 5 5 5
Functionality under WinCC
(TIA Portal)
Task planner
• time-controlled No No No
• task-controlled Yes Yes Yes
With alarm logging system
(incl. buffer and acknowledgment)
Number of bit messages 200 200 200
Number of analog messages 15 15 15
•Message buffer
- Number of entries 256 256 256
- Circulating buffer Yes Yes Yes
- retentive Yes Yes Yes
Recipes
Number of recipes 5 5 5
Size of internal recipe memory 40 kbyte 40 kbyte 40 kbyte
Recipe memory expandable No No No
Variables
Number of variables per device 250 500 500
Number of variables per screen 30 30 30
Images
Number of configurable images 50 50 50
Archiving
Number of archives per device 0 0 0
Security
Number of user groups 50 50 50
Number of users 50 50 50
Transfer (upload/download)
MPI/PROFIBUS DP No No No
•Ethernet Yes Yes Yes
6AV6647-0AH11-3AX0 6AV6647-0AJ11-3AX0 6AV6647-0AG11-3AX0
SIMATIC HMI KP300
Basic mono PN SIMATIC HMI KP400
Basic color PN SIMATIC HMI TP1500
Basic color PN
ST80_2013_EN_Kap02.book Seite 19 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Basic Panels
Basic Panels – Standard
2/20 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
Process coupling
• S7-1200 Yes Yes Yes
• S7-1500 Yes Yes Yes
• S7-200 Yes Yes Yes
• S7-300/400 Yes Yes Yes
• LOGO! Yes Yes Yes
•Win AC Yes No Yes
• SIMOTION No No No
Allen Bradley (EtherNet/IP) Yes Yes Yes
Allen Bradley (DF1) No No No
• Mitsubishi (MC TCP/IP) Yes Yes Yes
• Mitsubishi (FX) No No No
OMRON (FINS TCP) No No No
OMRON (LINK/Multilink) No No No
Modicon (Modbus TCP/IP) Yes Yes Yes
Modicon (Modbus) No No Yes
I/O
I/O devices
•Printer No No No
Multi Media Card No No No
•SD card No No No
USB memory No No No
Mechanics/material
Type of housing (front)
• Plastic Yes Yes Yes
Dimensions
Width of the housing front 165 mm 162 mm 400 mm
Height of housing front 97 mm 189 mm 310 mm
Mounting cutout (W x H x D)
Mounting cutout, width 149 mm 135 mm 367 mm
Mounting cutout, height 82 mm 171 mm 289 mm
Weight
Weight without packaging 0.25 kg 0.51 kg 4.2 kg
6AV6647-0AH11-3AX0 6AV6647-0AJ11-3AX0 6AV6647-0AG11-3AX0
SIMATIC HMI KP300
Basic mono PN SIMATIC HMI KP400
Basic color PN SIMATIC HMI TP1500
Basic color PN
ST80_2013_EN_Kap02.book Seite 20 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Basic Panels
Basic Panels – Standard
2/21
Siemens ST 80 / ST PC · 2013
2
Ordering data Order No. Order No.
SIMATIC HMI Basic Panels,
Key and Touch
SIMATIC HMI KTP400
Basic mono PN 6AV6647-0AA11-3AX0
SIMATIC HMI KTP400
Basic color PN 6AV6647-0AK11-3AX0
SIMATIC HMI KTP600
Basic mono PN 6AV6647-0AB11-3AX0
SIMATIC HMI KTP600
Basic color DP 6AV6647-0AC11-3AX0
SIMATIC HMI KTP600
Basic color PN 6AV6647-0AD11-3AX0
SIMATIC HMI KTP1000
Basic color DP 6AV6647-0AE11-3AX0
SIMATIC HMI KTP1000
Basic color PN 6AV6647-0AF11-3AX0
SIMATIC HMI Basic Panels, Key
SIMATIC HMI KP300
Basic mono PN 6AV6647-0AH11-3AX0
SIMATIC HMI KP400
Basic color PN 6AV6647-0AJ11-3AX0
SIMATIC HMI Basic Panels, Touch
SIMATIC HMI TP1500
Basic color PN 6AV6647-0AG11-3AX0
Starter kits
Starter kit SIMATIC S7-1200 +
KP300 Basic mono PN 6AV6651-7HA01-3AA3
Starter kit SIMATIC S7-1200 +
KTP400 Basic color PN 6AV6651-7KA01-3AA3
Starter kit SIMATIC S7-1200 +
KTP600 Basic color PN 6AV6651-7DA01-3AA3
Starter kits with an S7-1200
consist of:
• the respective SIMATIC HMI
Basic Panel
- SIMATIC HMI KP300
Basic mono PN
- SIMATIC HMI KTP400
Basic color PN
- SIMATIC HMI KTP600
Basic color PN
SIMATIC S7-1200 CPU 1212C
AC/DC/Rly
SIMATIC S7-1200
Simulator Module SIM 1274
• SIMATIC STEP 7 BASIC CD
SIMATIC S7-1200 HMI
Manual Collection CD
• Ethernet CAT5 cable, 2 m
LOGO! starter kit + KP300
Basic mono PN 6AV2132-0HA00-0AA0
LOGO! starter kit + KTP400
Basic color PN 6AV2132-0KA00-0AA0
Starter kits with a LOGO! consist of:
• the respective SIMATIC HMI
Basic Panel
- SIMATIC HMI KP300
Basic mono PN
- SIMATIC HMI KTP400
Basic color PN
LOGO! 12/24 RCE
• LOGO! POWER 24 V 1.3 A
LOGO! SOFT COMFORT V7
• WINCC BASIC (TIA Portal)
• Ethernet CAT5 cable, 2 m
Documentation
You can find the manual for the
Basic Panels on the Internet at: http://support.automation.sie-
mens.com
Accessories See HMI accessories,
from page 2/96
ST80_2013_EN_Kap02.book Seite 21 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Basic Panels
Basic Panels – Standard
2/22 Siemens ST 80 / ST PC · 2013
2
Dimensional drawings
All dimensions in mm. For installation cutout, see technical specifications.
KP300 Basic
KTP400 Basic mono PN
KTP400 Basic color PN
KP400 Basic
28.9
96.6
6.2
G_ST80_XX_00462
81
165
148
6.2
G_ST80_XX_00355
40
98
116
140
122
SIMATIC PANEL
39.7
33.5141
116
G_ST80_XX_00517
98
122
39.7
33.5
G_ST80_XX_00516
170
162
190
134
ST80_2013_EN_Kap02.book Seite 22 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Basic Panels
Basic Panels – Standard
2/23
Siemens ST 80 / ST PC · 2013
Dimensional drawings (continued)
2
KTP600 Basic
KTP1000 Basic
TP1500 Basic
More information
Additional information is available in the Internet under:
http://www.siemens.com/simatic-basic-panels
Note
Do you require a specific modification to or supplement for the
products described here? Look under "Customized products".
We provide information there about additional and generally
available sector products, and about the customer-specific
modification and adaptation options.
G_ST80_XX_00356
214
196
158
44
140
SSIMATIC PANEL
6.2
247
309
275
335
G_ST80_XX_00357
SSIMATIC PANEL
60.2 6.2
400
310
366
288
G_ST80_XX_00358
SSIMATIC PANEL
59.9 6.2
ST80_2013_EN_Kap02.book Seite 23 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIPLUS Basic Panels
SIPLUS Basic Panels
2/24 Siemens ST 80 / ST PC · 2013
2
Overview
Ideal entry-level series of 3.8 inches to 15 inches for operating
and monitoring compact machines and systems
Clear process representation through the use of full-graphic
displays
Intuitive operation via touch and tactile function keys
Equipped with all the necessary basic functions such as
reporting, recipe management, curve representation, vector
graphics, and language selection
Easy connection to the controller via integrated Ethernet
interface or a separate version with RS485/422
Note:
SIPLUS extreme products are based on Siemens Industry
standard products. The contents listed here were taken from the
respective standard products. SIPLUS extreme specific infor-
mation was added.
For technical documentation on SIPLUS, see:
http://www.siemens.com/siplus-extreme
SIPLUS HMI
KTP300 BASIC
MONO PN
SIPLUS HMI
KTP400 BASIC
MONO PN
SIPLUS HMI
KTP600 BASIC
COLOR PN
SIPLUS HMI
KTP1000 BASIC
COLOR DP
SIPLUS HMI
KTP1000 BASIC
COLOR PN
SIPLUS HMI
TP1500 BASIC
COLOR PN
Order number 6AG1647-
0AH11-2AX0 6AG1647-
0AA11-2AX0 6AG1647-
0AD11-2AX0 6AG1647-0AE11-
4AX0 6AG1647-0AF11-
4AX0 6AG1647-
0AG11-4AX0
Order No. based on 6AV6647-0AH11-
3AX0 6AV6647-0AA11-
3AX0 6AV6647-0AD11-
3AX0 6AV6647-0AE11-
3AX0 6AV6647-0AF11-
3AX0 6AV6647-0AG11-
3AX0
Ambient temperature range -25 ... +60 °C -10 ... +60 °C -25 ... +60 °C 0 ... +50 °C 0 ... +50 °C 0 ... +50 °C
Conformal coating Coating of the printed circuit boards and the electronic components
Technical data The technical data of the standard product applies except for the ambient conditions.
Ambient conditions
Relative humidity 100 %, condensation/frost permissible. No commissioning if condensation present.
Biologically active substances,
compliance with EN 60721-3-3 Class 3B2 mold and fungal spores (excluding fauna).
The supplied plug covers must remain in place over the unused interfaces during operation!
Chemically active substances,
compliance with EN 60721-3-3 Class 3C4 incl. salt spray in accordance with EN60068-2-52 (degree of severity 3).
The supplied plug covers must remain in place over the unused interfaces during operation!
Mechanically active substances,
compliance with EN 60721-3-3 Class 3S4 incl. sand, dust. The supplied plug covers must remain in place over the unused interfaces during opera-
tion!
Air pressure
(depending on the highest positive
temperature range specified)
1 080 ... 795 hPa (-1 000 ... +2 000 m)
see ambient temperature range
795 ... 658 hPa (+2000 ... +3500 m)
derating 10 K658 ... 540 hPa
(+3 500 ... +5 000 m)
derating 20 K
ST80_2013_EN_Kap02.book Seite 24 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIPLUS Basic Panels
SIPLUS Basic Panels
2/25
Siemens ST 80 / ST PC · 2013
2
Ordering data Order No. Order No.
Additional information is available in the Internet under:
http://www.siemens.com/simatic-basic-panels
Note
Do you require a specific modification to or supplement for the
products described here? Look under "Customized products".
We provide information there about additional and generally
available sector products, and about the customer-specific
modification and adaptation options.
SIPLUS HMI KTP300
Basic mono PN 6AG1647-0AH11-2AX0
For areas with extreme medial
exposure (conformal coating);
ambient temperature -25 ... +60 °C
SIPLUS HMI KTP400
Basic mono PN 6AG1647-0AA11-2AX0
For areas with extreme medial
exposure (conformal coating);
ambient temperature -10 ... +60 °C
SIPLUS HMI KTP600
Basic color PN 6AG1647-0AD11-2AX0
For areas with extreme medial
exposure (conformal coating);
ambient temperature -25 ... +60 °C
SIPLUS HMI KTP1000
Basic Color DP 6AG1647-0AE11-4AX0
For areas with extreme medial
exposure (conformal coating);
ambient temperature 0 ... +50 °C
SIPLUS HMI KTP1000
Basic Color PN 6AG1647-0AF11-4AX0
For areas with extreme medial
exposure (conformal coating);
ambient temperature 0 ... +50 °C
SIPLUS HMI TP1500
Basic Color PN 6AG1647-0AG11-4AX0
For areas with extreme medial
exposure (conformal coating);
ambient temperature 0 ... +50 °C
Accessories See SIMATIC Basic Panels,
from page 2/12
ST80_2013_EN_Kap02.book Seite 25 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Comfort Panels
Comfort Panels – Standard
2/26 Siemens ST 80 / ST PC · 2013
2
Overview
Excellent HMI functionality for demanding applications
Widescreen TFT displays with 4", 7", 9", 12", 15", 19" and 22"
diagonals (all 16 million colors) with up to 40% more visual-
ization area as compared to the predecessor devices
Integrated high-end functionality with archives, scripts,
PDF/Word/Excel viewer, Internet Explorer, Media Player and
Web Server
Dimmable displays from 0 to 100% via PROFIenergy, via the
HMI project or via a controller
Modern industrial design, cast aluminum fronts for 7" upwards
Upright installation for all touch devices
Optimal selection option: seven touch and five key versions
are available
Data security in the event of a power failure for the device and
for the SIMATIC HMI Memory Card
Innovative service and commissioning concept through
second SD card (automatic backup)
Easy project transfer via standard cable
(standard Ethernet cable, standard USB cable)
Maximum performance with short screen refresh times
Suitable for extremely harsh industrial environments thanks to
extended approvals such as ATEX 2/22 and marine approvals
Wide range of communication options: PROFIBUS and
PROFINET onboard; 2 x PROFINET with integrated switch for
7" models or larger; plus 1 x PROFINET with Gigabit support
for 15" models or larger
All variants can be used as an OPC UA client or as an OPC DA
server
Key-operated devices with LED in every function key and new
text input mechanism, similar to the keypads of mobile phones
All keys have a service life of 2 million operations
Configuring with the WinCC engineering software of the
TIA Portal
Technical specifications
6AV2124-2DC01-0AX0 6AV2124-0GC01-0AX0 6AV2124-0JC01-0AX0 6AV2124-0MC01-0AX0
SIMATIC HMI KTP400
Comfort SIMATIC HMI TP700
Comfort SIMATIC HMI TP900
Comfort SIMATIC HMI TP1200
Comfort
Display
Design of display TFT TFT TFT TFT
Screen diagonal 4.3 in 7in 9in 12.1 in
Number of colors 16 777 200 16 777 200 16 777 200 16 777 200
Resolution (pixels)
Horizontal image resolution 480 800 800 1280
Vertical image resolution 272 480 480 800
Backlighting
MTBF backlighting (at 25 °C) 80 000 h 80 000 h 80 000 h 80 000 h
Dimmable backlight Yes; 0-100 % Yes; 0-100 % Yes; 0-100 % Yes; 0-100 %
Control elements
Keyboard fonts
Number of function keys 4 0 0 0
Touch operation
Design as touch screen Yes Yes Yes Yes
Installation type/mounting
Mounting in portrait format
possible Yes Yes Yes Yes
Supply voltage
Type of supply voltage DC DC DC DC
Rated voltage/DC 24 V 24 V 24 V 24 V
Memory
Usable memory for user data 4Mbyte 12 Mbyte 12 Mbyte 12 Mbyte
Type of output
Acoustics
• Speaker No Yes Yes Yes
ST80_2013_EN_Kap02.book Seite 26 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Comfort Panels
Comfort Panels – Standard
2/27
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
Time of day
Clock
Hardware clock
(real-time clock) Yes Yes Yes Yes
• Battery-backed Yes Yes Yes Yes
• Synchronizable Yes Yes Yes Yes
Interfaces
Number of RS 485 interfaces 1; RS 422/485 combined 1; RS 422/485 combined 1; RS 422/485 combined 1; RS 422/485 combined
Number of USB interfaces 1; USB 2.0 2; USB 2.0 2; USB 2.0 2; USB 2.0
Number of USB Mini B
interfaces 1; 5-pole 1; 5-pole 1; 5-pole 1; 5-pole
Number of SD card slots 2 2 2 2
Industrial Ethernet
Number of industrial Ethernet
interfaces 1 2 2 2
Number of ports of the
integrated switch 1 2 2 2
Protocols
PROFINET Yes Yes Yes Yes
IRT supported No Yes Yes Yes
MRP supported No Yes Yes Yes
PROFIBUS Yes Yes Yes Yes
MPI Yes Yes Yes Yes
Degree and class of
protection
Type of protection IP20 IP20 IP20 IP20
IP (at the front) IP65 IP65 IP65 IP65
Enclosure type 4x at the front Yes Yes Yes Yes
Standards, approvals,
certificates
CE Yes Yes Yes Yes
cULus Yes Yes Yes Yes
GL Yes Yes Yes Yes
ABS Yes Yes Yes Yes
BV Yes Yes Yes Yes
DNV Yes Yes Yes Yes
LRS Yes Yes Yes Yes
Class NK No; Available soon No; Available soon No; Available soon No; Available soon
PRS No No No No
Use in hazardous areas
ATEX Zone 2 Yes Yes Yes Yes
ATEX Zone 22 Yes Yes Yes Yes
cULus Class I Zone 2,
Division 2 Yes Yes Yes Yes
FM Class I Division 2 Yes Yes Yes Yes
Ambient conditions
Operating temperature
Operation
(vertical installation)
- in vertical mounting
position/ minimum C 0°C C 0°C
- in vertical mounting
position/ maximum 50 °C 50 °C 50 °C 50 °C
Relative humidity
max. relative humidity 90 % 90 % 90 % 90 %
Configuration
Configuration software
WinCC Comfort (TIA Portal) Yes; from V11 Yes; from V11 Yes; from V11 Yes; from V11
6AV2124-2DC01-0AX0 6AV2124-0GC01-0AX0 6AV2124-0JC01-0AX0 6AV2124-0MC01-0AX0
SIMATIC HMI KTP400
Comfort SIMATIC HMI TP700
Comfort SIMATIC HMI TP900
Comfort SIMATIC HMI TP1200
Comfort
ST80_2013_EN_Kap02.book Seite 27 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Comfort Panels
Comfort Panels – Standard
2/28 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
Languages
Online languages
Number of online/runtime
languages 32 32 32 32
Functionality under WinCC
(TIA Portal)
Applications/options
Internet Explorer Yes Yes Yes Yes
•Pocket Word Yes Yes Yes Yes
Pocket Excel Yes Yes Yes Yes
PDF Viewer Yes Yes Yes Yes
Media Player Yes Yes Yes Yes
SIMATIC WinCC Sm@rtServer Yes Yes Yes Yes
Visual Basic Scripts Yes Yes Yes Yes
Task planner
• time-controlled Yes Yes Yes Yes
• task-controlled Yes Yes Yes Yes
With alarm logging system (incl.
buffer and acknowledgment)
Number of bit messages 2000 4 000 4000 4000
Number of analog messages 50 200 200 200
•Message buffer
- Number of entries 256 1 024 1024 1024
- Circulating buffer Yes Yes Yes Yes
- retentive Yes Yes Yes Yes
Recipes
Number of recipes 100 300 300 300
Size of internal recipe memory 512 kbyte 2Mbyte 2Mbyte 2Mbyte
Recipe memory expandable Yes Yes Yes Yes
Variables
Number of variables per
device 1024 2 048 2048 2048
Number of variables per
screen 50 400 400 400
Images
Number of configurable
images 500 500 500 500
Archiving
Number of archives per
device 10 50 50 50
Security
Number of user groups 50 50 50 50
Number of users 50 50 50 50
SIMATIC Logon Yes Yes Yes Yes
Logging through printer
• Alarms Yes Yes Yes Yes
Report (shift log) Yes Yes Yes Yes
• Hardcopy Yes Yes Yes Yes
Electronic print to file Yes; pdf, html Yes; pdf, html Yes; pdf, html Yes; pdf, html
Transfer (upload/download)
MPI/PROFIBUS DP Yes Yes Yes Yes
•USB Yes Yes Yes Yes
•Ethernet Yes Yes Yes Yes
6AV2124-2DC01-0AX0 6AV2124-0GC01-0AX0 6AV2124-0JC01-0AX0 6AV2124-0MC01-0AX0
SIMATIC HMI KTP400
Comfort SIMATIC HMI TP700
Comfort SIMATIC HMI TP900
Comfort SIMATIC HMI TP1200
Comfort
ST80_2013_EN_Kap02.book Seite 28 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Comfort Panels
Comfort Panels – Standard
2/29
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
Process coupling
• S7-1200 Yes Yes Yes Yes
• S7-1500 Yes Yes Yes Yes
• S7-200 Yes Yes Yes Yes
• S7-300/400 Yes Yes Yes Yes
• LOGO! Yes Yes Yes Yes
•Win AC Yes Yes Yes Yes
• SIMOTION No; With WinCC, subsequent
version No; With WinCC, subsequent
version No; With WinCC, subsequent
version No; With WinCC, subsequent
version
Allen Bradley (EtherNet/IP) Yes Yes Yes Yes
Allen Bradley (DF1) Yes Yes Yes Yes
• Mitsubishi (MC TCP/IP) Yes Yes Yes Yes
• Mitsubishi (FX) Yes Yes Yes Yes
OMRON (FINS TCP) No No No No
OMRON (LINK/Multilink) Yes Yes Yes Yes
Modicon (Modbus TCP/IP) Yes Yes Yes Yes
Modicon (Modbus) Yes Yes Yes Yes
• OPC UA Client Yes Yes Yes Yes
OPC UA Server No No No No
I/O
I/O devices
•Printer Yes Yes Yes Yes
Multi Media Card Yes Yes Yes Yes
•SD card Yes Yes Yes Yes
USB memory Yes Yes Yes Yes
Network camera Yes Yes Yes Yes
Mechanics/material
Type of housing (front)
• Plastic Yes No No No
•Aluminum No Yes Yes Yes
Dimensions
Width of the housing front 140 mm 214 mm 274 mm 330 mm
Height of housing front 116 mm 158 mm 190 mm 241 mm
Mounting cutout (W x H x D)
Mounting cutout, width 123 mm 197 mm 251 mm 310 mm
Mounting cutout, height 99 mm 141 mm 166 mm 221 mm
Weight
Weight without packaging 0.6 kg 1.4 kg 1.9 kg 2.8 kg
6AV2124-1DC01-0AX0 6AV2124-1GC01-0AX0 6AV2124-1JC01-0AX0 6AV2124-1MC01-0AX0 6AV2124-1QC02-0AX0
SIMATIC HMI
KP400 Comfort SIMATIC HMI
KP700 Comfort SIMATIC HMI
KP900 Comfort SIMATIC HMI
KP1200 Comfort SIMATIC HMI
KP1500 Comfort
Display
Design of display TFT TFT TFT TFT TFT
Screen diagonal 4.3 in 7in 9in 12.1 in 15.4 in
Number of colors 16 777 200 16 777 200 16 777 200 16 777 200 16 777 200
Resolution (pixels)
Horizontal image resolution 480 800 800 1280 1 280
Vertical image resolution 272 480 480 800 800
Backlighting
MTBF backlighting (at 25 °C) 80 000 h 80 000 h 80 000 h 80 000 h 80 000 h
Dimmable backlight Yes; 0-100 % Yes; 0-100 % Yes; 0-100 % Yes; 0-100 % Yes; 0-100 %
Control elements
Keyboard fonts
Number of function keys 824 26 34 36
Touch operation
Design as touch screen No No No No No
Installation type/mounting
Mounting in portrait format
possible No No No No No
Supply voltage
Type of supply voltage DC DC DC DC DC
Rated voltage/DC 24 V 24 V 24 V 24 V 24 V
6AV2124-2DC01-0AX0 6AV2124-0GC01-0AX0 6AV2124-0JC01-0AX0 6AV2124-0MC01-0AX0
SIMATIC HMI KTP400
Comfort SIMATIC HMI TP700
Comfort SIMATIC HMI TP900
Comfort SIMATIC HMI TP1200
Comfort
ST80_2013_EN_Kap02.book Seite 29 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Comfort Panels
Comfort Panels – Standard
2/30 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
Memory
Usable memory for user data 4Mbyte 12 Mbyte 12 Mbyte 12 Mbyte 24 Mbyte
Type of output
Acoustics
• Speaker No Yes Yes Yes Yes
Time of day
Clock
Hardware clock
(real-time clock) Yes Yes Yes Yes Yes
• Battery-backed Yes Yes Yes Yes Yes
• Synchronizable Yes Yes Yes Yes Yes
Interfaces
Number of RS 485 interfaces 1; RS 422/485
combined 1; RS 422/485
combined 1; RS 422/485
combined 1; RS 422/485
combined 1; RS 422/485
combined
Number of USB interfaces 1; USB 2.0 2; USB 2.0 2; USB 2.0 2; USB 2.0 2; USB 2.0
Number of USB Mini B
interfaces 1; 5-pole 1; 5-pole 1; 5-pole 1; 5-pole 1; 5-pole
Number of SD card slots 22222
Industrial Ethernet
Number of industrial Ethernet
interfaces 12223
Number of ports of the
integrated switch 12222
Protocols
PROFINET Yes Yes Yes Yes Yes
IRT supported No Yes Yes Yes Yes
MRP supported No Yes Yes Yes Yes
PROFIBUS Yes Yes Yes Yes Yes
MPI Yes Yes Yes Yes Yes
Degree and class of
protection
Type of protection IP20 IP20 IP20 IP20 IP20
IP (at the front) IP65 IP65 IP65 IP65 IP65
Enclosure type 4x at the front Yes Yes Yes Yes Yes
Standards, approvals,
certificates
CE Yes Yes Yes Yes Yes
cULus Yes Yes Yes Yes Yes
GL Yes Yes Yes Yes No
ABS Yes Yes Yes Yes No
BV Yes Yes Yes Yes No
DNV Yes Yes Yes Yes No
LRS Yes Yes Yes Yes No
Class NK No; Available soon No; Available soon No; Available soon No; Available soon No
PRS No No No No No
Use in hazardous areas
ATEX Zone 2 No; Available soon Yes Yes Yes No
ATEX Zone 22 No; Available soon Yes Yes Yes No
cULus Class I Zone 2,
Division 2 Yes Yes Yes Yes Yes
FM Class I Division 2 Yes Yes Yes Yes Yes
Ambient conditions
Operating temperature
Operation (vertical
installation)
- in vertical mounting
position/ minimum C C C C C
- in vertical mounting
position/ maximum 50 °C 50 °C 50 °C 50 °C 50 °C
Relative humidity
max. relative humidity 90 % 90 % 90 % 90 % 90 %
6AV2124-1DC01-0AX0 6AV2124-1GC01-0AX0 6AV2124-1JC01-0AX0 6AV2124-1MC01-0AX0 6AV2124-1QC02-0AX0
SIMATIC HMI
KP400 Comfort SIMATIC HMI
KP700 Comfort SIMATIC HMI
KP900 Comfort SIMATIC HMI
KP1200 Comfort SIMATIC HMI
KP1500 Comfort
ST80_2013_EN_Kap02.book Seite 30 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Comfort Panels
Comfort Panels – Standard
2/31
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
Configuration
Configuration software
WinCC Comfort (TIA Portal) Yes; from V11 Yes; from V11 Yes; from V11 Yes; from V11 Yes; V11 SP2 or higher
Languages
Online languages
Number of online/runtime
languages 32 32 32 32 32
Functionality under WinCC
(TIA Portal)
Applications/options
Internet Explorer Yes Yes Yes Yes Yes
•Pocket Word Yes Yes Yes Yes Yes
Pocket Excel Yes Yes Yes Yes Yes
PDF Viewer Yes Yes Yes Yes Yes
Media Player Yes Yes Yes Yes Yes
SIMATIC WinCC Sm@rtServer Yes Yes Yes Yes Yes
Visual Basic Scripts Yes Yes Yes Yes Yes
Task planner
• time-controlled Yes Yes Yes Yes Yes
• task-controlled Yes Yes Yes Yes Yes
With alarm logging system (incl.
buffer and acknowledgment)
Number of bit messages 2000 4000 4000 4000 6 000
Number of analog messages 50 200 200 200 200
•Message buffer
- Number of entries 256 1024 1024 1024 1 024
- Circulating buffer Yes Yes Yes Yes Yes
- retentive Yes Yes Yes Yes Yes
Recipes
Number of recipes 100 300 300 300 500
Size of internal recipe memory 512 kbyte 2Mbyte 2Mbyte 2Mbyte 4Mbyte
Recipe memory expandable Yes Yes Yes Yes Yes
Variables
Number of variables per
device 1024 2048 2048 2048 4 096
Number of variables per
screen 50 400 400 400 400
Images
Number of configurable
images 500 500 500 500 750
Archiving
Number of archives per
device 10 50 50 50 50
Security
Number of user groups 50 50 50 50 50
Number of users 50 50 50 50 50
SIMATIC Logon Yes Yes Yes Yes Yes
Logging through printer
• Alarms Yes Yes Yes Yes Yes
Report (shift log) Yes Yes Yes Yes Yes
• Hardcopy Yes Yes Yes Yes Yes
Electronic print to file Yes; pdf, html Yes; pdf, html Yes; pdf, html Yes; pdf, html Yes; pdf, html
Transfer (upload/download)
MPI/PROFIBUS DP Yes Yes Yes Yes Yes
•USB Yes Yes Yes Yes Yes
•Ethernet Yes Yes Yes Yes Yes
6AV2124-1DC01-0AX0 6AV2124-1GC01-0AX0 6AV2124-1JC01-0AX0 6AV2124-1MC01-0AX0 6AV2124-1QC02-0AX0
SIMATIC HMI
KP400 Comfort SIMATIC HMI
KP700 Comfort SIMATIC HMI
KP900 Comfort SIMATIC HMI
KP1200 Comfort SIMATIC HMI
KP1500 Comfort
ST80_2013_EN_Kap02.book Seite 31 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Comfort Panels
Comfort Panels – Standard
2/32 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
Process coupling
• S7-1200 Yes Yes Yes Yes Yes
• S7-1500 Yes Yes Yes Yes Yes
• S7-200 Yes Yes Yes Yes Yes
• S7-300/400 Yes Yes Yes Yes Yes
• LOGO! Yes Yes Yes Yes Yes
•Win AC Yes Yes Yes Yes Yes
• SIMOTION No; With WinCC,
subsequent version No; With WinCC,
subsequent version No; With WinCC,
subsequent version No; With WinCC,
subsequent version No; With WinCC,
subsequent version
Allen Bradley (EtherNet/IP) Yes Yes Yes Yes Yes
Allen Bradley (DF1) Yes Yes Yes Yes Yes
• Mitsubishi (MC TCP/IP) Yes Yes Yes Yes Yes
• Mitsubishi (FX) Yes Yes Yes Yes Yes
OMRON (FINS TCP) No No No No No
OMRON (LINK/Multilink) Yes Yes Yes Yes Yes
Modicon (Modbus TCP/IP) Yes Yes Yes Yes Yes
Modicon (Modbus) Yes Yes Yes Yes Yes
• OPC UA Client Yes Yes Yes Yes Yes
OPC UA Server No No No No No
I/O
I/O devices
•Printer Yes Yes Yes Yes Yes
Multi Media Card Yes Yes Yes Yes Yes
•SD card Yes Yes Yes Yes Yes
USB memory Yes Yes Yes Yes Yes
Network camera Yes Yes Yes Yes Yes
Mechanics/material
Type of housing (front)
• Plastic Yes No No No No
•Aluminum No Yes Yes Yes Yes
Dimensions
Width of the housing front 152 mm 308 mm 362 mm 454 mm 483 mm
Height of housing front 188 mm 204 mm 230 mm 289 mm 310 mm
Mounting cutout (W x H x D)
Mounting cutout, width 135 mm 281 mm 338 mm 434 mm 450 mm
Mounting cutout, height 171 mm 177 mm 206 mm 269 mm 291 mm
Weight
Weight without packaging 0.8 kg 2.2 kg 2.7 kg 4.4 kg 5.4 kg
6AV2124-1DC01-0AX0 6AV2124-1GC01-0AX0 6AV2124-1JC01-0AX0 6AV2124-1MC01-0AX0 6AV2124-1QC02-0AX0
SIMATIC HMI
KP400 Comfort SIMATIC HMI
KP700 Comfort SIMATIC HMI
KP900 Comfort SIMATIC HMI
KP1200 Comfort SIMATIC HMI
KP1500 Comfort
ST80_2013_EN_Kap02.book Seite 32 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Comfort Panels
Comfort Panels – Standard
2/33
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
6AV2124-0QC02-0AX0 6AV2124-0UC02-0AX0 6AV2124-0XC02-0AX0
SIMATIC HMI TP1500 Comfort SIMATIC HMI TP1900 Comfort SIMATIC HMI TP2200 Comfort
Display
Design of display TFT TFT TFT
Screen diagonal 15.4 in 18.5 in 21.5 in
Number of colors 16 777 200 16 777 200 16 777 200
Resolution (pixels)
Horizontal image resolution 1280 1366 1 920
Vertical image resolution 800 768 1 080
Backlighting
MTBF backlighting (at 25 °C) 80 000 h 50 000 h 30 000 h
Dimmable backlight Yes; 0-100 % Yes; 0-100 % Yes; 0-100 %
Control elements
Keyboard fonts
Number of function keys 000
Touch operation
Design as touch screen Yes Yes Yes
Installation type/mounting
Mounting in portrait format
possible Yes Yes Yes
Supply voltage
Type of supply voltage DC DC DC
Rated voltage/DC 24 V 24 V 24 V
Memory
Usable memory for user data 24 Mbyte 24 Mbyte 24 Mbyte
Type of output
Acoustics
• Speaker Yes Yes Yes
Time of day
Clock
Hardware clock
(real-time clock) Yes Yes Yes
• Battery-backed Yes Yes Yes
• Synchronizable Yes Yes Yes
Interfaces
Number of RS 485 interfaces 1; RS 422/485 combined 1; RS 422/485 combined 1; RS 422/485 combined
Number of USB interfaces 2; USB 2.0 2; USB 2.0 2; USB 2.0
Number of USB Mini B
interfaces 1; 5-pole 1; 5-pole 1; 5-pole
Number of SD card slots 222
Industrial Ethernet
Number of industrial Ethernet
interfaces 333
Number of ports of the
integrated switch 222
Protocols
PROFINET Yes Yes Yes
IRT supported Yes Yes Yes
MRP supported Yes Yes Yes
PROFIBUS Yes Yes Yes
MPI Yes Yes Yes
Degree and class of
protection
Type of protection IP20 IP20 IP20
IP (at the front) IP65 IP65 IP65
Enclosure type 4x at the front Yes Yes Yes
ST80_2013_EN_Kap02.book Seite 33 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Comfort Panels
Comfort Panels – Standard
2/34 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
Standards, approvals,
certificates
CE Yes Yes Yes
cULus Yes Yes Yes
GL No No No
ABS No No No
BV No No No
DNV No No No
LRS No No No
Class NK No No No
PRS No No No
Use in hazardous areas
ATEX Zone 2 No No No
ATEX Zone 22 No No No
cULus Class I Zone 2,
Division 2 Yes Yes Yes
FM Class I Division 2 Yes Yes Yes
Ambient conditions
Operating temperature
Operation (vertical
installation)
- in vertical mounting
position/ minimum C C C
- in vertical mounting
position/ maximum 50 °C 45 °C 45 °C
Relative humidity
max. relative humidity 90 % 90 % 90 %
Configuration
Configuration software
WinCC Comfort (TIA Portal) Yes; V11 SP2 or higher Yes; V11 SP2 or higher Yes; V11 SP2 or higher
Languages
Online languages
Number of online/runtime
languages 32 32 32
Functionality under WinCC
(TIA Portal)
Applications/options
Internet Explorer Yes Yes Yes
•Pocket Word Yes Yes Yes
Pocket Excel Yes Yes Yes
PDF Viewer Yes Yes Yes
Media Player Yes Yes Yes
SIMATIC WinCC Sm@rtServer Yes Yes Yes
Visual Basic Scripts Yes Yes Yes
Task planner
• time-controlled Yes Yes Yes
• task-controlled Yes Yes Yes
With alarm logging system (incl.
buffer and acknowledgment)
Number of bit messages 6000 6000 6 000
Number of analog messages 200 200 200
•Message buffer
- Number of entries 1024 1024 1 024
- Circulating buffer Yes Yes Yes
- retentive Yes Yes Yes
Recipes
Number of recipes 500 500 500
Size of internal recipe memory 4Mbyte 4Mbyte 4Mbyte
Recipe memory expandable Yes Yes Yes
Variables
Number of variables per
device 4096 4096 4 096
Number of variables per
screen 400 400 400
6AV2124-0QC02-0AX0 6AV2124-0UC02-0AX0 6AV2124-0XC02-0AX0
SIMATIC HMI TP1500 Comfort SIMATIC HMI TP1900 Comfort SIMATIC HMI TP2200 Comfort
ST80_2013_EN_Kap02.book Seite 34 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Comfort Panels
Comfort Panels – Standard
2/35
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
Images
Number of configurable
images 750 750 750
Archiving
Number of archives per
device 50 50 50
Security
Number of user groups 50 50 50
Number of users 50 50 50
SIMATIC Logon Yes Yes Yes
Logging through printer
• Alarms Yes Yes Yes
Report (shift log) Yes Yes Yes
• Hardcopy Yes Yes Yes
Electronic print to file Yes; pdf, html Yes; pdf, html Yes; pdf, html
Transfer (upload/download)
MPI/PROFIBUS DP Yes Yes Yes
•USB Yes Yes Yes
•Ethernet Yes Yes Yes
Process coupling
• S7-1200 Yes Yes Yes
• S7-1500 Yes Yes Yes
• S7-200 Yes Yes Yes
• S7-300/400 Yes Yes Yes
• LOGO! Yes Yes Yes
•Win AC Yes Yes Yes
• SIMOTION No; With WinCC, subsequent version No; With WinCC, subsequent version No; With WinCC, subsequent version
Allen Bradley (EtherNet/IP) Yes Yes Yes
Allen Bradley (DF1) Yes Yes Yes
• Mitsubishi (MC TCP/IP) Yes Yes Yes
• Mitsubishi (FX) Yes Yes Yes
OMRON (FINS TCP) No No No
OMRON (LINK/Multilink) Yes Yes Yes
Modicon (Modbus TCP/IP) Yes Yes Yes
Modicon (Modbus) Yes Yes Yes
• OPC UA Client Yes Yes Yes
OPC UA Server No No No
I/O
I/O devices
•Printer Yes Yes Yes
Multi Media Card Yes Yes Yes
•SD card Yes Yes Yes
USB memory Yes Yes Yes
Network camera Yes Yes Yes
Mechanics/material
Type of housing (front)
• Plastic No No No
•Aluminum Yes Yes Yes
Dimensions
Width of the housing front 415 mm 483 mm 560 mm
Height of housing front 310 mm 337 mm 380 mm
Mounting cutout (W x H x D)
Mounting cutout, width 396 mm 465 mm 542 mm
Mounting cutout, height 291 mm 319 mm 362 mm
Weight
Weight without packaging 5.2 kg 6.5 kg 7.1 kg
6AV2124-0QC02-0AX0 6AV2124-0UC02-0AX0 6AV2124-0XC02-0AX0
SIMATIC HMI TP1500 Comfort SIMATIC HMI TP1900 Comfort SIMATIC HMI TP2200 Comfort
ST80_2013_EN_Kap02.book Seite 35 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Comfort Panels
Comfort Panels – Standard
2/36 Siemens ST 80 / ST PC · 2013
2
Ordering data Order No. Order No.
SIMATIC HMI Comfort Panels,
Key and Touch
SIMATIC HMI KTP400 Comfort 6AV2124-2DC01-0AX0
SIMATIC HMI Comfort Panels,
Touch
SIMATIC HMI TP700 Comfort 6AV2124-0GC01-0AX0
SIMATIC HMI TP900 Comfort 6AV2124-0JC01-0AX0
SIMATIC HMI TP1200 Comfort 6AV2124-0MC01-0AX0
SIMATIC HMI TP1500 Comfort 6AV2124-0QC02-0AX0
SIMATIC HMI TP1900 Comfort 6AV2124-0UC02-0AX0
SIMATIC HMI TP2200 Comfort 6AV2124-0XC02-0AX0
SIMATIC HMI Comfort Panels, Key
SIMATIC HMI KP400 Comfort 6AV2124-1DC01-0AX0
SIMATIC HMI KP700 Comfort 6AV2124-1GC01-0AX0
SIMATIC HMI KP900 Comfort 6AV2124-1JC01-0AX0
SIMATIC HMI KP1200 Comfort 6AV2124-1MC01-0AX0
SIMATIC HMI KP1500 Comfort 6AV2124-1QC02-0AX0
Starter kits for SIMATIC HMI
Comfort Panels
Consisting of:
the respective SIMATIC HMI
Comfort Panel, SIMATIC WinCC
Comfort, Ethernet cable, 2 m
SIMATIC HMI memory card 2 GB
10 protective films for touch screen
devices
Starter kit for SIMATIC HMI
KTP400 Comfort,
Key and Touch
6AV2181-4DB20-0AX0
Starter kit for SIMATIC HMI
TP700 Comfort, Touch 6AV2181-4GB00-0AX0
Starter kit for SIMATIC HMI
TP900 Comfort, Touch 6AV2181-4JB00-0AX0
Starter kit for SIMATIC HMI
TP1200 Comfort, Touch 6AV2181-4MB00-0AX0
Starter kit for SIMATIC HMI
TP1500 Comfort, Touch 6AV2181-4QB00-0AX0
Starter kit for SIMATIC HMI
TP1900 Comfort, Touch 6AV2181-4UB00-0AX0
Starter kit for SIMATIC HMI
TP2200 Comfort, Touch 6AV2181-4XB00-0AX0
Starter kit for SIMATIC HMI
KP400 Comfort, Key 6AV2181-4DB10-0AX0
Starter kit for SIMATIC HMI
KP700 Comfort, Key 6AV2181-4GB10-0AX0
Starter kit for SIMATIC HMI
KP900 Comfort, Key 6AV2181-4JB10-0AX0
Starter kit for SIMATIC HMI
KP1200 Comfort, Key 6AV2181-4MB10-0AX0
Starter kit for SIMATIC HMI
KP1500 Comfort, Key 6AV2181-4QB10-0AX0
Accessories See HMI accessories,
from page 2/96
ST80_2013_EN_Kap02.book Seite 36 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Comfort Panels
Comfort Panels – Standard
2/37
Siemens ST 80 / ST PC · 2013
2
Dimensional drawings
All dimensions in mm. For installation cutout, see technical specifications.
TP700 Comfort
TP900 Comfort
TP1200 Comfort
TP1500 Comfort
62.8
32.5
G_ST80_XX_00449
214
158
140
196
69
69.3
63.1
32.5
194.7
138.8
G_ST80_XX_00450
164
274
190
249
70.5
64.3
32.5
194.7
138.8
G_ST80_XX_00451
219
330
241
308
79.3
73.1
47.6
G_ST80_XX_00511
394
182
289
415
310
281
ST80_2013_EN_Kap02.book Seite 37 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Comfort Panels
Comfort Panels – Standard
2/38 Siemens ST 80 / ST PC · 2013
Dimensional drawings (continued)
2
TP1900 Comfort
TP2200 Comfort
KP400 Comfort
KP700 Comfort
79.3
73.1
47.6
G_ST80_XX_00512
483
337
182
317
281
463
79.3
73.1
47.6
G_ST80_XX_00513
182
360
281
540
560
380
55.8
G_ST80_XX_00444
134
152 18
48
98
170
188
62.8
32.5
138.8
194.7
G_ST80_XX_00445
280
308
176
204
69
ST80_2013_EN_Kap02.book Seite 38 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Comfort Panels
Comfort Panels – Standard
2/39
Siemens ST 80 / ST PC · 2013
Dimensional drawings (continued)
2
KP900 Comfort
KP1200 Comfort
KP1500 Comfort
KTP400 Comfort
More information
Additional information is available on the Internet at:
http://www.siemens.com/simatic-comfort-panels
You can find an overview of approved printers, supply sources
and printer settings on the Internet at:
http://support.automation.siemens.com/WW/view/en/11376409
Note
Do you need a specific modification or extension to the products
described here? If so, refer to "Customized Automation". There
you will find information about additional and generally available
sector-specific products as well as options for customer-specific
modification and adaptation.
62.8
32.5
138.8
194.7
G_ST80_XX_00446
336
362
204
230
69
70.5
64.5
32.5
194.7
138.8
G_ST80_XX_00447
432
454
267
289
79.3
73.1
47.6
G_ST80_XX_00510
448
483
182
289
310
281
54.8
48.6
G_ST80_XX_00448
140
98
116
18
122
ST80_2013_EN_Kap02.book Seite 39 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIPLUS Comfort Panels
SIPLUS Comfort Panels
2/40 Siemens ST 80 / ST PC · 2013
2
Overview
Excellent HMI functionality for demanding applications
Widescreen TFT displays with 4", 7", 9", 12", 15", 19" and 22"
diagonals (all 16 million colors) with up to 40% more visual-
ization area as compared to the predecessor devices
Integrated high-end functionality with archives, scripts,
PDF/Word/Excel viewer, Internet Explorer, Media Player
Dimmable displays from 0 to 100% via PROFIenergy, via the
HMI project or via a controller
Modern industrial design, cast aluminum fronts for 7" upwards
Upright installation for all touch devices
Optimal selection option: seven touch and five key versions
are available
Data security in the event of a power failure for the device and
for the SIMATIC HMI Memory Card
Innovative service and commissioning concept through
second SD card (automatic backup)
Easy project transfer via standard cable
(standard Ethernet cable, standard USB cable)
Maximum performance with short screen refresh times
Suitable for extremely harsh industrial environments thanks to
extended approvals such as ATEX 2/22
Wide range of communication options: PROFIBUS and
PROFINET onboard; 2x PROFINET with integrated switch for
7" models or larger; plus 1 additional PROFINET with Gigabit
support for 15" models or larger
All variants can be used as an OPC UA client or as an OPC DA
server
Key-operated devices with LED in every function key and new
text input mechanism, similar to the keypads of mobile phones
Key-operated devices with stamped keys for optimum tactile
feedback
All keys have a service life of 2 million operations
Configuring with the WinCC engineering software of the
TIA Portal
Note:
SIPLUS extreme products are based on Siemens Industry
standard products. The contents listed here were taken from the
respective standard products. SIPLUS extreme-specific infor-
mation was added.
ST80_2013_EN_Kap02.book Seite 40 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIPLUS Comfort Panels
SIPLUS Comfort Panels
2/41
Siemens ST 80 / ST PC · 2013
2
Technical specifications
6AG1124-2DC01-4AX0 6AG1124-0GC01-4AX0 6AG1124-0JC01-4AX0 6AG1124-0MC01-4AX0
SIPLUS HMI KTP400
Comfort SIPLUS HMI TP700
Comfort SIPLUS HMI TP900
Comfort SIPLUS HMI TP1200
Comfort
Ambient conditions
Operating temperature
Operation
(vertical installation)
- in vertical mounting
position/ minimum C 0°C C 0°C
- in vertical mounting
position/ maximum 50 °C 50 °C 50 °C 50 °C
Extended ambient conditions
Relative humidity
- With condensation/
maximum/tested in accor-
dance with IEC 60068-2-38
100 % 100 % 100 % 100 %
• Resistance
- to biologically active
substances Yes Yes Yes Yes
- to chemically active
substances Yes Yes Yes Yes
- to mechanically active
substances Yes Yes Yes Yes
6AG1124-1DC01-4AX0 6AG1124-1GC01-4AX0 6AG1124-1JC01-4AX0 6AG1124-1MC01-4AX0 6AG1124-1QC02-4AX0
SIPLUS HMI KTP400
Comfort SIPLUS HMI KP700
Comfort SIPLUS HMI KP900
Comfort SIPLUS HMI KP1200
Comfort SIPLUS HMI KP1500
Comfort
Ambient conditions
Operating temperature
Operation
(vertical installation)
- in vertical mounting
position/ minimum C C C C C
- in vertical mounting
position/ maximum 50 °C 50 °C 50 °C 50 °C 50 °C
Extended ambient conditions
Relative humidity
- With condensation/
maximum/tested in accor-
dance with IEC 60068-2-38
100 % 100 % 100 % 100 % 100 %
• Resistance
- to biologically active
substances Yes Yes Yes Yes Yes
- to chemically active
substances Yes Yes Yes Yes Yes
- to mechanically active
substances Yes Yes Yes Yes Yes
ST80_2013_EN_Kap02.book Seite 41 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIPLUS Comfort Panels
SIPLUS Comfort Panels
2/42 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
6AG1124-0QC02-4AX0 6AG1124-0UC02-4AX0 6AG1124-0XC02-4AX0
SIPLUS HMI TP1500 Comfort SIPLUS HMI TP1900 Comfort SIPLUS HMI TP2200 Comfort
Ambient conditions
Operating temperature
Operation
(vertical installation)
- in vertical mounting
position/ minimum C C C
- in vertical mounting
position/ maximum 50 °C 45 °C 45 °C
Extended ambient conditions
Relative humidity
- With condensation/
maximum/tested in accor-
dance with IEC 60068-2-38
100 % 100 % 100 %
• Resistance
- to biologically active
substances Yes Yes Yes
- to chemically active
substances Yes Yes Yes
- to mechanically active
substances Yes Yes Yes
ST80_2013_EN_Kap02.book Seite 42 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIPLUS Comfort Panels
SIPLUS Comfort Panels
2/43
Siemens ST 80 / ST PC · 2013
2
Ordering data Order No.
More information
Additional information is available on the Internet at:
http://www.siemens.com/simatic-comfort-panels
You can find an overview of approved printers, supply sources
and printer settings on the Internet at:
http://support.automation.siemens.com/WW/view/en/11376409
Note
Do you need a specific modification or extension to the products
described here? If so, refer to "Customized Automation". There
you will find information about additional and generally available
sector-specific products as well as options for customer-specific
modification and adaptation.
SIPLUS HMI Comfort Panels,
Keys and Touch
SIPLUS HMI KTP400 Comfort 6AG1124-2DC01-4AX0
SIPLUS HMI Comfort Panels,
Touch
SIPLUS HMI TP700 Comfort 6AG1124-0GC01-4AX0
SIPLUS HMI TP900 Comfort 6AG1124-0JC01-4AX0
SIPLUS HMI TP1200 Comfort 6AG1124-1MC01-4AX0
SIPLUS HMI TP1500 Comfort 6AG1124-0QC02-4AX0
SIPLUS HMI TP1900 Comfort 6AG1124-0UC02-4AX0
SIPLUS HMI TP2200 Comfort 6AG1124-0XC02-4AX0
SIPLUS HMI Comfort Panels,
Keys
SIPLUS HMI KP400 Comfort 6AG1124-1DC01-4AX0
SIPLUS HMI KP700 Comfort 6AG1124-1GC01-4AX0
SIPLUS HMI KP900 Comfort 6AG1124-1JC01-4AX0
SIPLUS HMI KP1200 Comfort 6AG1124-1MC01-4AX0
SIPLUS HMI KP1500 Comfort 6AG1124-1QC02-4AX0
Accessories See HMI accessories,
from page 2/26
ST80_2013_EN_Kap02.book Seite 43 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Mobile Panels
Mobile Panels
2/44 Siemens ST 80 / ST PC · 2013
2
Overview
SIMATIC Mobile Panel
Mobile operator panel for direct operator control of the plant
and machine from any point
Supports an optimum view of the workpiece or process and,
at the same time, direct access and visual contact with the
operator panel
Versatile use thanks to easy unplugging and replugging
during normal operation (Mobile Panel 177 and
Mobile Panel 277) or
Wireless freedom (Mobile Panel 277(F) IWLAN)
Pixel-graphics, high-luminance color display with touch
screen (analog/resistive)
PROFIBUS or PROFINET communication, PROFINET over
WLAN for Mobile Panel 277(F) IWLAN
Freely-configurable function keys with customized labels
(with LED) (not for Mobile Panel 277 10")
SIMATIC Mobile Panel 177 and SIMATIC Mobile Panel 277
Two three-stage acknowledgement buttons;
Optional versions include:
- STOP button
- STOP button, handwheel, key-operated switch and
illuminated pushbutton (not for Mobile Panel 277 10")
Communication is supported via a serial link, MPI/PROFIBUS
or PROFINET
Connection point recognition for local identification of the
device based on the connection point ID
Fast system availability after plugging into the connection
boxes
Connection to the controller and power supply is made via the
connection box and the connecting cable
SIMATIC Mobile Panel 277(F) IWLAN
Wireless, mobile operator panel for flexible and location-
independent system and machine operation
WLAN communication in accordance with
IEEE 802.11 (a/b/g/h) and PROFINET support
Powerful batteries and flexible concept for changing permit
battery replacement "on the fly" without interrupting operation
Effective range limitation and the local identification of the
device by using transponder technology
Low-cost, safety-related mobile operator control and
monitoring via RFID technology (MOBY D) for plants with
pre-installed safety resources (e.g. robot cells)
Optional variants with: Handwheel, key switch and illuminated
pushbutton
Fail-safe operator controls of the
SIMATIC Mobile Panel 277F IWLAN using PROFIsafe:
- Two three-stage acknowledgment buttons
- Emergency stop button
IWLAN Access Points SCALANCE W for
SIMATIC Mobile Panel 277(F) IWLAN
The Access Points of the product line SCALANCE W-780 are
ideally suited for setting up Industrial Wireless LAN (IWLAN)
radio networks for 2.4 GHz and 5 GHz with data rates of up to
54 Mbps; they can be used for all applications that require a
high degree of operational reliability, even under extremely
harsh ambient conditions
Suitable for any application:
- SCALANCE W-788 for cabinet-free installation
- SCALANCE W-786 for cabinet-free installation, also with
integral antennas
- SCALANCE W-784 for installation in control cabinets or
integration into devices
Wireless communication suitable for use in applications with
high real-time and reliability requirements, such as PROFINET,
PROFIsafe or video
Standard-compliant thanks to IEEE 802.11 support, additional
functional expansions especially for use with increased
reliability
Effective encryption mechanisms protect against
unauthorized access, spying, tapping, and corruption
The SINEMA E engineering tool, wizards and online help
support planning, simulation, configuration and documen-
tation; easy management with the web server and SNMP
Fast commissioning of the Access Points thanks to the
optional swap medium PRESET-PLUG and fast device
replacement in the event of a fault thanks to the optional swap
medium C-PLUG (Configuration Plug)
Accessories such as antennas, connectors, cables incl.
RCoax cables (radiating cables) that are tuned to one another
for a reliable radio link.
ST80_2013_EN_Kap02.book Seite 44 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Mobile Panels — 170 series
SIMATIC Mobile Panel 177
2/45
Siemens ST 80 / ST PC · 2013
2
Overview
SIMATIC Mobile Panel 177
Technical specifications
6AV6645-0AA01-0AX0 6AV6645-0AB01-0AX0 6AV6645-0AC01-0AX0
with integrated acknowledgment
button with integrated acknowledgment
button and STOP button with integrated acknowledgment
button, STOP button, handwheel,
keyswitch and illuminated pushbutton
Display
Size 5.7" (121 mm x 92 mm) 5.7" (121 mm x 92 mm) 5.7" (121 mm x 92 mm)
Display type STN, 256 colors STN, 256 colors STN, 256 colors
Resolution (pixels)
Resolution (WxH in pixel) 320 x 240 320 x 240 320 x 240
Backlighting
MTBF backlighting (at 25 °C) about 50,000 hours about 50,000 hours about 50,000 hours
MTBF backlighting (at 25 °C) 50 000 h 50 000 h 50 000 h
Control elements
Operating options Keys and Touch Keys and Touch Keys and Touch
Function keys, programmable 14 function keys, 8 with LEDs 14 function keys, 8 with LEDs 14 function keys, 8 with LEDs
Keyboard fonts
System keys 000
Touch operation
Touch screen Analog, resistive Analog, resistive Analog, resistive
Special operator controls
Stop button No Yes Yes
Acknowledgement button Yes Yes Yes
Key-operated switch No No Yes
Illuminated pushbutton No No Yes
• Handwheel No No Yes
Supply voltage
Supply voltage via connection box via connection box via connection box
Processor
Processor RISC 32-bit, 200 MHz RISC 32-bit, 200 MHz RISC 32-bit, 200 MHz
Memory
Type Flash / RAM Flash / RAM Flash / RAM
Usable memory for user data 2048 KB of usable memory for
user data / no user memory for options 2048 KB of usable memory for
user data / no user memory for options 2048 KB of usable memory for
user data / no user memory for options
Battery
Backup battery
Battery operation maximum buffer time 10 min maximum buffer time 10 min maximum buffer time 10 min
ST80_2013_EN_Kap02.book Seite 45 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Mobile Panels — 170 series
SIMATIC Mobile Panel 177
2/46 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
Interfaces
Interfaces 1 x RS422, 1 x RS485 (max. 12 Mbit/s) 1 x RS422, 1 x RS485 (max. 12 Mbit/s) 1 x RS422, 1 x RS485 (max. 12 Mbit/s)
USB port No No No
Number of USB interfaces 000
PC card slot No No No
CF card slot No No No
SD card slot No
Multimedia card/SD card slot combined combined combined
Industrial Ethernet
Industrial Ethernet interface No No No
Degree and class of
protection
IP65 enclosure Yes Yes Yes
Standards, approvals,
certificates
Certifications CE, cULus, C-TICK, SIBE CE, cULus, C-TICK, SIBE CE, cULus, C-TICK, SIBE
CE Yes Yes Yes
cULus Yes Yes Yes
C-TICK Yes
Safety category according to
EN954-1 Safety category according to EN954-1
(acknowledgment button, STOP button
if present) 3
Safety category according to EN954-1
(acknowledgment button, STOP button
if present) 3
Safety category according to EN954-1
(acknowledgment button, STOP button
if present) 3
Highest safety class achievable
in safety mode
Performance Level in accor-
dance with EN ISO 13849-1 ddd
Ambient conditions
Drop height 1.5 m 1.5 m 1.5 m
Operating temperature
•Operation 0 °C to +40 °C 0 °C to +40 °C 0 °C to +40 °C
Storage/transport temperature
Transport, storage -20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C
Relative humidity
max. relative humidity 80 % 80 % 80 %
Operating systems
Operating system Windows CE Windows CE Windows CE
Languages
Online languages
Number of online/runtime
languages 555
Functionality under WinCC
(TIA Portal)
Libraries Yes Yes Yes
Task planner Yes Yes Yes
With alarm logging system (incl.
buffer and acknowledgment)
Number of messages 2000 2000 2 000
Bit messages Yes Yes Yes
Analog messages Yes Yes Yes
Recipes
Number of recipes 100 100 100
Data records per recipe 200 200 200
Entries per data record 200 200 200
Recipe memory 32 KB integrated Flash, expandable 32 KB integrated Flash, expandable 32 KB integrated Flash, expandable
6AV6645-0AA01-0AX0 6AV6645-0AB01-0AX0 6AV6645-0AC01-0AX0
with integrated acknowledgment
button with integrated acknowledgment
button and STOP button with integrated acknowledgment
button, STOP button, handwheel,
keyswitch and illuminated pushbutton
ST80_2013_EN_Kap02.book Seite 46 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Mobile Panels — 170 series
SIMATIC Mobile Panel 177
2/47
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
Variables
Number of variables per
device 1024 1024 1 024
• Limit values Yes Yes Yes
• Multiplexing Yes Yes Yes
Images
Number of configurable
images 500 500 500
Image objects
Text objects 2,500 text elements 2,500 text elements 2,500 text elements
Graphics object Bit maps, vector graphics Bit maps, vector graphics Bit maps, vector graphics
Complex image objects
Status/control With SIMATIC S7 With SIMATIC S7 With SIMATIC S7
dynamic objects Diagrams, bar graphs, sliders, invisible
buttons Diagrams, bar graphs, sliders, invisible
buttons Diagrams, bar graphs, sliders, invisible
buttons
Lists
Number of text lists per
project 300 300 300
Number of graphics lists per
project 100 100 100
Archiving
Number of archives per
device 000
Security
Number of user groups 50 50 50
Number of user rights 32 32 32
Password export/import Yes Yes Yes
Data carrier support
•PC card No No No
•CF card No No No
Logging through printer
• Recording/Printing ---
Transfer (upload/download)
Transfer of configuration MPI/PROFIBUS DP, serial, automatic
transfer recognition MPI/PROFIBUS DP, serial, automatic
transfer recognition MPI/PROFIBUS DP, serial, automatic
transfer recognition
Process coupling
Connection to controller S5, S7-200, S7- 300/400, TI 505,
Win AC, SINUMERIK, SIMOTION, Allen
Bradley (DF1), Allen Bradley (DF485),
Mitsubishi (FX), OMRON (LINK/Multi-
link), Modicon (Modbus),
further non-Siemens drivers,
see chapter "System interfaces"
S5, S7-200, S7- 300/400, TI 505,
Win AC, SINUMERIK, SIMOTION, Allen
Bradley (DF1), Allen Bradley (DF485),
Mitsubishi (FX), OMRON (LINK/Multi-
link), Modicon (Modbus),
further non-Siemens drivers,
see chapter "System interfaces"
S5, S7-200, S7- 300/400, TI 505,
Win AC, SINUMERIK, SIMOTION, Allen
Bradley (DF1), Allen Bradley (DF485),
Mitsubishi (FX), OMRON (LINK/Multi-
link), Modicon (Modbus),
further non-Siemens drivers,
see chapter "System interfaces"
• S7-1200 Yes Yes Yes
• S7-1500 Yes Yes Yes
Expandability/openness
Open Platform Program Yes Yes Yes
I/O
I/O devices
Multi Media Card Yes Yes Yes
Mechanics/material
Type of housing (front) Plastic Plastic Plastic
Dimensions
Housing diameter/depth (mm) Dia 245 mm / D 58 mm Dia 245 mm / D 58 mm Dia 245 mm / D 58 mm
Weight
Weight 1.3 kg 1.3 kg 1.3 kg
6AV6645-0AA01-0AX0 6AV6645-0AB01-0AX0 6AV6645-0AC01-0AX0
with integrated acknowledgment
button with integrated acknowledgment
button and STOP button with integrated acknowledgment
button, STOP button, handwheel,
keyswitch and illuminated pushbutton
ST80_2013_EN_Kap02.book Seite 47 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Mobile Panels — 170 series
SIMATIC Mobile Panel 177
2/48 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
6AV6645-0BA01-0AX0 6AV6645-0BB01-0AX0 6AV6645-0BC01-0AX0
with integrated acknowledgment
button with integrated acknowledgment
button and STOP button with integrated acknowledgment
button, STOP button, handwheel,
keyswitch and illuminated pushbutton
Display
Size 5.7" (121 mm x 92 mm) 5.7" (121 mm x 92 mm) 5.7" (121 mm x 92 mm)
Display type STN, 256 colors STN, 256 colors STN, 256 colors
Resolution (pixels)
Resolution (WxH in pixel) 320 x 240 320 x 240 320 x 240
Backlighting
MTBF backlighting (at 25 °C) about 50,000 hours about 50,000 hours about 50,000 hours
MTBF backlighting (at 25 °C) 50 000 h 50 000 h 50 000 h
Control elements
Operating options Keys and Touch Keys and Touch Keys and Touch
Function keys, programmable 14 function keys, 8 with LEDs 14 function keys, 8 with LEDs 14 function keys, 8 with LEDs
Keyboard fonts
System keys 000
Touch operation
Touch screen Analog, resistive Analog, resistive Analog, resistive
Special operator controls
Stop button No Yes Yes
Acknowledgement button Yes Yes Yes
Key-operated switch No No Yes
Illuminated pushbutton No No Yes
• Handwheel No No Yes
Supply voltage
Supply voltage via connection box via connection box via connection box
Processor
Processor RISC 32-bit, 200 MHz RISC 32-bit, 200 MHz RISC 32-bit, 200 MHz
Memory
Type Flash / RAM Flash / RAM Flash / RAM
Usable memory for user data 2048 KB of usable memory for user
data / no user memory for options 2048 KB of usable memory for user
data / no user memory for options 2048 KB of usable memory for user
data / no user memory for options
Battery
Backup battery
Battery operation maximum buffer time 10 min maximum buffer time 10 min maximum buffer time 10 min
Interfaces
Interfaces 1 x RS485, 1 x Ethernet (RJ45) 1 x RS485, 1 x Ethernet (RJ45) 1 x RS485, 1 x Ethernet (RJ45)
USB port No No No
Number of USB interfaces 000
PC card slot No No No
CF card slot No No No
Multimedia card/SD card slot combined combined combined
Industrial Ethernet
Industrial Ethernet interface 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45)
Protocols
PROFINET Yes Yes Yes
Supports protocol for
PROFINET IO Yes Yes Yes
Degree and class of
protection
IP65 enclosure Yes Yes Yes
ST80_2013_EN_Kap02.book Seite 48 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Mobile Panels — 170 series
SIMATIC Mobile Panel 177
2/49
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
Standards, approvals,
certificates
Certifications CE, cULus, C-TICK, SIBE CE, cULus, C-TICK, SIBE CE, cULus, C-TICK, SIBE
CE Yes Yes Yes
cULus Yes Yes Yes
Safety category according to
EN954-1 Safety category according to EN954-1
(acknowledgment button, STOP button
if present) 3
Safety category according to EN954-1
(acknowledgment button, STOP button
if present) 3
Safety category according to EN954-1
(acknowledgment button, STOP button
if present) 3
Highest safety class achievable
in safety mode
Performance Level in accor-
dance with EN ISO 13849-1 ddd
Ambient conditions
Drop height 1.5 m 1.5 m 1.5 m
Operating temperature
•Operation 0 °C to +40 °C 0 °C to +40 °C 0 °C to +40 °C
Storage/transport temperature
Transport, storage -20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C
Relative humidity
max. relative humidity 80 % 80 % 80 %
Operating systems
Operating system Windows CE Windows CE Windows CE
Languages
Online languages
Number of online/runtime
languages 555
Functionality under WinCC
(TIA Portal)
Libraries Yes Yes Yes
Task planner Yes Yes Yes
With alarm logging system (incl.
buffer and acknowledgment)
Number of messages 2000 2000 2 000
Bit messages Yes Yes Yes
Analog messages Yes Yes Yes
Recipes
Number of recipes 100 100 100
Data records per recipe 200 200 200
Entries per data record 200 200 200
Recipe memory 32 KB integrated Flash, expandable 32 KB integrated Flash, expandable 32 KB integrated Flash, expandable
Variables
Number of variables per
device 1024 1024 1 024
• Limit values Yes Yes Yes
• Multiplexing Yes Yes Yes
Images
Number of configurable
images 500 500 500
Image objects
Text objects 2,500 text elements 2,500 text elements 2,500 text elements
Graphics object Bit maps, vector graphics Bit maps, vector graphics Bit maps, vector graphics
Complex image objects
Status/control With SIMATIC S7 With SIMATIC S7 With SIMATIC S7
dynamic objects Diagrams, bar graphs, sliders, invisible
buttons Diagrams, bar graphs, sliders, invisible
buttons Diagrams, bar graphs, sliders, invisible
buttons
6AV6645-0BA01-0AX0 6AV6645-0BB01-0AX0 6AV6645-0BC01-0AX0
with integrated acknowledgment
button with integrated acknowledgment
button and STOP button with integrated acknowledgment
button, STOP button, handwheel,
keyswitch and illuminated pushbutton
ST80_2013_EN_Kap02.book Seite 49 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Mobile Panels — 170 series
SIMATIC Mobile Panel 177
2/50 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
Lists
Number of text lists
per project 300 300 300
Number of graphics lists
per project 100 100 100
Archiving
Number of archives
per device 000
Security
Number of user groups 50 50 50
Number of user rights 32 32 32
Password export/import Yes Yes Yes
Data carrier support
•PC card No No No
•CF card No No No
Logging through printer
• Recording/Printing ---
Transfer (upload/download)
Transfer of configuration Serial, Ethernet, automatic transfer
recognition Serial, Ethernet, automatic transfer
recognition Serial, Ethernet, automatic transfer
recognition
Process coupling
Connection to controller S7-200, S7- 300/400, Win AC, PC
(TCP/IP), SIMOTION, Modicon
(Modbus), see the chapter "System
interfaces"
S7-200, S7- 300/400, Win AC, PC
(TCP/IP), SIMOTION, Modicon
(Modbus), see the chapter "System
interfaces"
S7-200, S7- 300/400, Win AC, PC
(TCP/IP), SIMOTION, Modicon
(Modbus), see the chapter "System
interfaces"
• S7-1200 Yes Yes Yes
• S7-1500 Yes Yes Yes
Expandability/openness
Open Platform Program Yes Yes Yes
I/O
I/O devices Printer Printer Printer
Multi Media Card Yes Yes Yes
Mechanics/material
Type of housing (front) Plastic Plastic Plastic
Dimensions
Housing diameter/depth (mm) Dia 245 mm / D 58 mm Dia 245 mm / D 58 mm Dia 245 mm / D 58 mm
Weight
Weight 1.3 kg 1.3 kg 1.3 kg
6AV6645-0BA01-0AX0 6AV6645-0BB01-0AX0 6AV6645-0BC01-0AX0
with integrated acknowledgment
button with integrated acknowledgment
button and STOP button with integrated acknowledgment
button, STOP button, handwheel,
keyswitch and illuminated pushbutton
ST80_2013_EN_Kap02.book Seite 50 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Mobile Panels — 170 series
SIMATIC Mobile Panel 177
2/51
Siemens ST 80 / ST PC · 2013
2
Ordering data Order No.
1) The system components (connecting cables and connection boxes) must
be ordered separately.
2) Delivery time approximately 6 weeks
Dimensional drawings
All dimensions in mm. For installation cutout, see technical
specifications.
Mobile Panel 177, front and side view
More information
Additional information is available in the Internet under:
http://www.siemens.com/simatic-mobile-panels
Note
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about additional sector-specific
products that can be ordered as well as about options for
customer-specific modification and adaptation.
SIMATIC Mobile Panel 177 DP
(MPI/PROFIBUS) 1)
With integrated acknowledgement
button 6AV6645-0AA01-0AX0
With integrated acknowledgement
button and STOP button 6AV6645-0AB01-0AX0
With integrated acknowledgement
button, STOP button, handwheel,
key-operated switch and
illuminated pushbutton
6AV6645-0AC01-0AX0
SIMATIC Mobile Panel 177 PN
(PROFINET) 1)
With integrated acknowledgement
button 6AV6645-0BA01-0AX0
With integrated acknowledgement
button and STOP button 6AV6645-0BB01-0AX0
With integrated acknowledgement
button, STOP button, handwheel,
key-operated switch and
illuminated pushbutton
6AV6645-0BC01-0AX0
Documentation
You can find the manuals for the
Mobile Panels on the Internet at:
http://support.automation.sie-
mens.com/WW/view/en/11599011/
133300
SIMATIC HMI Manual Collection 6AV6691-1SA01-0AX0
Electronic documentation on DVD,
5 languages (English, German,
French, Italian and Spanish); con-
tains: all currently available user
manuals, device manuals and
communication manuals for
SIMATIC HMI
System components for
Mobile Panels
DP connection box for
Mobile Panels
(MPI/PROFIBUS)
•Basic 6AV6671-5AE00-0AX0
•Plus 6AV6671-5AE10-0AX0
PN connection box for
Mobile Panel (PROFINET)
•Basic 6AV6671-5AE01-0AX0
•Plus 6AV6671-5AE11-0AX0
Connecting cable and
accessories for Mobile Panels See HMI accessories,
from page 2/99
121.7
123.9
61.3
245
92.3
7.80
G_ST80_XX_00046
ST80_2013_EN_Kap02.book Seite 51 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277
2/52 Siemens ST 80 / ST PC · 2013
2
Overview
SIMATIC Mobile Panel 277 8" SIMATIC Mobile Panel 277 10"
Technical specifications
6AV6645-0CA01-0AX0 6AV6645-0CB01-0AX0 6AV6645-0CC01-0AX0 6AV6645-0BE02-0AX0
8" with integrated
acknowledgment button 8" with integrated
acknowledgment button
and STOP button
8" with integrated
acknowledgment button,
STOP button, handwheel,
keyswitch and illuminated
pushbutton
10" with integrated
acknowledgment button
and STOP button
Display
Size 7.5" 7.5" 7.5" 10.4"
Display type TFT, 65536 colors TFT, 65536 colors TFT, 65536 colors TFT, 65536 colors
Resolution (pixels)
Resolution (WxH in pixel) 640 x 480 640 x 480 640 x 480 800 x 600
Backlighting
MTBF backlighting (at 25 °C) about 50,000 hours about 50,000 hours about 50,000 hours about 50,000 hours
MTBF backlighting (at 25 °C) 50 000 h 50 000 h 50 000 h 50 000 h
Control elements
Operating options Keys and Touch Keys and Touch Keys and Touch Touch
Function keys, programmable 18 function keys, 18 with
LEDs 18 function keys, 18 with
LEDs 18 function keys, 18 with
LEDs none
Connection for mouse/
keyboard/barcode reader USB / USB / USB USB / USB / USB USB / USB / USB USB / USB / USB
Keyboard fonts
System keys 0
Touch operation
Touch screen Analog, resistive Analog, resistive Analog, resistive Analog, resistive
Special operator controls
Stop button No Yes Yes Yes
Acknowledgement button Yes Yes Yes Yes
Key-operated switch No No Yes No
Illuminated pushbutton No No Yes; Two illuminated
pushbuttons No
• Handwheel No No Yes No
ST80_2013_EN_Kap02.book Seite 52 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277
2/53
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
Supply voltage
Supply voltage via connection box via connection box via connection box via connection box, DC
Processor
Processor ARM, 520 MHz ARM, 520 MHz ARM, 520 MHz ARM, 520
Memory
Type Flash / RAM Flash / RAM Flash / RAM Flash / RAM
Usable memory for user data 6 MB usable memory for user
data 6 MB usable memory for user
data 6 MB usable memory for user
data 6 MB usable memory for user
data
Battery
Backup battery
Battery operation maximum buffer time 10 min maximum buffer time 10 min maximum buffer time 10 min maximum buffer time 10 min
- Charging duration 5h
- Number of loading cycles,
min 500
Time of day
Clock
• Type Hardware clock, battery
backup, synchronizable Hardware clock, battery
backup, synchronizable Hardware clock, battery
backup, synchronizable Hardware clock, battery
backup, synchronizable
Interfaces
Interfaces 1 x RS422, 1 x RS485,
1 x Ethernet (RJ45)
(max. 12 Mbit/s)
1 x RS422, 1 x RS485,
1 x Ethernet (RJ45)
(max. 12 Mbit/s)
1 x RS422, 1 x RS485,
1 x Ethernet (RJ45)
(max. 12 Mbit/s)
1 x RS422, 1 x RS485,
1 x Ethernet (RJ45)
(max. 12 Mbit/s)
USB port 1 x USB 1 x USB 1 x USB 1 x USB
Multi Media Card slot 1 MMC/SD card slot 1 MMC/SD card slot 1 MMC/SD card slot
Multimedia card/SD card slot combined
Industrial Ethernet
Industrial Ethernet interface 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45)
Protocols
PROFINET Yes Yes Yes Yes
Supports protocol for
PROFINET IO Yes Yes Yes Yes
Degree and class of
protection
IP65 enclosure Yes Yes Yes Yes
Standards, approvals,
certificates
Certifications CE, cULus, C-TICK, SIBE CE, cULus, C-TICK, SIBE CE, cULus, C-TICK, SIBE CE, cULus, C-TICK, SIBE
Safety category according to
EN954-1 Safety category according to
EN954-1 (acknowledgment
button, STOP button if pres-
ent) 3
Safety category according to
EN954-1 (acknowledgment
button, STOP button if pres-
ent) 3
Safety category according to
EN954-1 (acknowledgment
button, STOP button if pres-
ent) 3
Safety category according to
EN954-1 (acknowledgment
button, STOP button if pres-
ent) 3
Highest safety class achievable
in safety mode
Performance Level in accor-
dance with EN ISO 13849-1 d d d d
6AV6645-0CA01-0AX0 6AV6645-0CB01-0AX0 6AV6645-0CC01-0AX0 6AV6645-0BE02-0AX0
8" with integrated
acknowledgment button 8" with integrated
acknowledgment button
and STOP button
8" with integrated
acknowledgment button,
STOP button, handwheel,
keyswitch and illuminated
pushbutton
10" with integrated
acknowledgment button
and STOP button
ST80_2013_EN_Kap02.book Seite 53 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277
2/54 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
Ambient conditions
Drop height 1.2 m 1.2 m 1.2 m 1m
Operating temperature
•Operation 0 °C to +40 °C 0 °C to +40 °C 0 °C to +40 °C 0 °C to +40 °C
Storage/transport temperature
Transport, storage -20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C
Relative humidity
max. relative humidity 80 % 80 % 80 % 80 %
Operating systems
Operating system Windows CE Windows CE Windows CE Windows CE
Languages
Online languages
Number of online/runtime
languages 16 16 16 16
Functionality under WinCC
(TIA Portal)
Libraries Yes Yes Yes Yes
Task planner Yes Yes Yes Yes
With alarm logging system (incl.
buffer and acknowledgment)
Number of messages 4000 4 000 4000 4000
Bit messages Yes Yes Yes Yes
Analog messages Yes Yes Yes Yes
Recipes
Number of recipes 300 300 300 300
Data records per recipe 500 500 500 200
Entries per data record 1000 1 000 1000 1000
Recipe memory 64 KB integrated Flash,
expandable 64 KB integrated Flash,
expandable 64 KB integrated Flash,
expandable 64 KB integrated Flash,
expandable
Variables
Number of variables
per device 2048 2 048 2048 2048
• Limit values Yes Yes Yes Yes
• Multiplexing Yes Yes Yes Yes
Images
Number of configurable
images 500 500 500 500
Image objects
Text objects 10,000 text elements 10,000 text elements 10,000 text elements 10,000 text elements
Graphics object Bit maps, icons, vector
graphics Bit maps, icons, vector
graphics Bit maps, icons, vector
graphics Bit maps, icons, vector
graphics
Complex image objects
Status/control With SIMATIC S7 With SIMATIC S7 With SIMATIC S7 With SIMATIC S7
dynamic objects Diagrams, bar graphs,
sliders, analog display,
invisible buttons
Diagrams, bar graphs,
sliders, analog display,
invisible buttons
Diagrams, bar graphs,
sliders, analog display,
invisible buttons
Diagrams, bar graphs,
sliders, analog display,
invisible buttons
6AV6645-0CA01-0AX0 6AV6645-0CB01-0AX0 6AV6645-0CC01-0AX0 6AV6645-0BE02-0AX0
8" with integrated
acknowledgment button 8" with integrated
acknowledgment button
and STOP button
8" with integrated
acknowledgment button,
STOP button, handwheel,
keyswitch and illuminated
pushbutton
10" with integrated
acknowledgment button
and STOP button
ST80_2013_EN_Kap02.book Seite 54 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277
2/55
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
Lists
Number of text lists per
project 500 500 500 500
Number of graphics lists per
project 400 400 400 400
Archiving
Number of archives per
device 20 20 20 20
Number of measuring points
per project 20 20 20 20
Number of entries per archive 10 000 10 000 10 000 10 000
Security
Number of user groups 50 50 50 50
Number of user rights 32 32 32 32
Password export/import Yes Yes Yes Yes
Logging through printer
• Recording/Printing Alarms, report (shift report),
color print, hardcopy Alarms, report (shift report),
color print, hardcopy Alarms, report (shift report),
color print, hardcopy Alarms, report (shift report),
color print, hardcopy,
PROFINET
Transfer (upload/download)
Transfer of configuration MPI/PROFIBUS DP, USB,
Ethernet, automatic transfer
recognition
MPI/PROFIBUS DP, USB,
Ethernet, automatic transfer
recognition
MPI/PROFIBUS DP, USB,
Ethernet, automatic transfer
recognition
MPI/PROFIBUS DP, USB,
Ethernet, automatic transfer
recognition
Process coupling
Connection to controller S5, S7-200, S7-300/400,
TI 505, Win AC, PC (TCP/IP),
SINUMERIK, SIMOTION,
Allen Bradley (DF1), Allen
Bradley (DF485), Mitsubishi
(FX), OMRON (LINK/Multil-
ink), Modicon (Modbus),
further non-Siemens drivers,
see chapter "System inter-
faces"
S5, S7-200, S7- 300/400,
TI 505, SINUMERIK,
SIMOTION, Allen Bradley
(DF1), Allen Bradley (DF485),
Mitsubishi (FX), OMRON
(LINK/Multilink), Modicon
(Modbus),
further non-Siemens drivers,
see chapter "System inter-
faces"
S5, S7-200, S7- 300/400,
TI 505, SINUMERIK,
SIMOTION, Allen Bradley
(DF1), Allen Bradley (DF485),
Mitsubishi (FX), OMRON
(LINK/Multilink), Modicon
(Modbus),
further non-Siemens drivers,
see chapter "System inter-
faces"
S5, S7-200, S7- 300/400,
TI 505, Win AC, SINUMERIK,
SIMOTION, Allen Bradley
(DF1), Allen Bradley (DF485),
Mitsubishi (FX), OMRON
(LINK/Multilink), Modicon
(Modbus),
further non-Siemens drivers,
see chapter "System inter-
faces"
• S7-1200 Yes Yes Yes Yes
• S7-1500 Yes Yes Yes Yes
I/O
I/O devices Printer, barcode reader Printer, barcode reader Printer, barcode reader Printer, barcode reader
Multi Media Card Yes Yes Yes Yes
Mechanics/material
Type of housing (front) Plastic Plastic Plastic Plastic
Dimensions
Housing diameter/depth (mm) Dia 290 mm / D 103 mm Dia 290 mm / D 103 mm Dia 290 mm / D 103 mm
Weight
Weight 1.7 kg 1.7 kg 1.7 kg 2.3 kg
6AV6645-0CA01-0AX0 6AV6645-0CB01-0AX0 6AV6645-0CC01-0AX0 6AV6645-0BE02-0AX0
8" with integrated
acknowledgment button 8" with integrated
acknowledgment button
and STOP button
8" with integrated
acknowledgment button,
STOP button, handwheel,
keyswitch and illuminated
pushbutton
10" with integrated
acknowledgment button
and STOP button
ST80_2013_EN_Kap02.book Seite 55 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277
2/56 Siemens ST 80 / ST PC · 2013
2
Ordering data Order No.
1) The system components (connecting cables and connection boxes) must
be ordered separately.
2) Delivery time approximately 6 weeks
Dimensional drawings
All dimensions in mm. For installation cutout, see technical
specifications.
Mobile Panel 277 8", front and side view
Mobile Panel 277 10", front and side view
More information
Additional information is available in the Internet under:
http://www.siemens.com/simatic-mobile-panels
Note
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about additional sector-specific
products that can be ordered as well as about options for
customer-specific modification and adaptation.
SIMATIC Mobile Panel 277 8" 1)
With integrated acknowledgement
button 6AV6645-0CA01-0AX0
With integrated acknowledgement
button and STOP button 6AV6645-0CB01-0AX0
With integrated acknowledgement
button, STOP button, handwheel,
key-operated switch and two illu-
minated pushbuttons
6AV6645-0CC01-0AX0
SIMATIC Mobile Panel 277 10"
With integrated acknowledgement
button and STOP button 6AV6645-0BE02-0AX0
Documentation
You can find the manuals for the
Mobile Panels on the Internet at:
http://support.automation.sie-
mens.com/WW/view/en/11599011/
133300
SIMATIC HMI Manual Collection 6AV6691-1SA01-0AX0
Electronic documentation, on DVD
5 languages (English, French,
German, Italian and Spanish);
contains: all currently available user
manuals, device manuals and
communication manuals for
SIMATIC HMI
System components
for Mobile Panels
DP connection box for
Mobile Panels (MPI/PROFIBUS)
•Basic 6AV6671-5AE00-0AX0
•Plus 6AV6671-5AE10-0AX0
PN connection box for
Mobile Panel (PROFINET)
•Basic 6AV6671-5AE01-0AX0
•Plus 6AV6671-5AE11-0AX0
Connecting cable and
accessories for Mobile Panels See HMI accessories,
from page 2/99
9
117
155
103
129Ø 290
G_ST80_XX_00277
212
320
159
129
103
350
G_ST80_XX_00354
ST80_2013_EN_Kap02.book Seite 56 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277(F) IWLAN
2/57
Siemens ST 80 / ST PC · 2013
2
Overview
SIMATIC Mobile Panel 277(F) IWLAN
Technical specifications
6AV6645-0DD01-0AX1 6AV6645-0DE01-0AX1 6AV6645-0EB01-0AX1 6AV6645-0EC01-0AX1 6AV6645-0EF01-0AX1
RFID TAG
with integrated
handwheel,
keyoperated switch
and two illuminated
pushbuttons
with integrated
acknowledgement
button and emergency
stop button
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
Display
Size 7.5" 7.5" 7.5" 7.5" 7.5"
Display type TFT, 65536 colors TFT, 65536 colors TFT, 65536 colors TFT, 65536 colors TFT, 65536 colors
Resolution (pixels)
Resolution (WxH in pixel) 640 x 480 640 x 480 640 x 480 640 x 480 640 x 480
Backlighting
MTBF backlighting
(at 25 °C) about 50,000 hours about 50,000 hours about 50,000 hours about 50,000 hours about 50,000 hours
MTBF backlighting
(at 25 °C) 50 000 h 50 000 h 50 000 h 50 000 h 50 000 h
Control elements
Operating options Keys and Touch Keys and Touch Keys and Touch Keys and Touch Keys and Touch
Function keys,
programmable 18 function keys,
18 with LEDs 18 function keys,
18 with LEDs 18 function keys,
18 with LEDs 18 function keys,
18 with LEDs 18 function keys,
18 with LEDs
Connection for mouse/
keyboard/barcode reader USB / USB / USB USB / USB / USB USB / USB / USB USB / USB / USB USB / USB / USB
Touch operation
Touch screen Analog, resistive Analog, resistive Analog, resistive Analog, resistive Analog, resistive
Special operator controls
Stop button No No Yes Yes Yes
• Acknowledgement
button No No Yes Yes Yes
Key-operated switch No Yes No Yes Yes
Illuminated pushbutton No Yes No Yes Yes
• Handwheel No Yes No Yes Yes
ST80_2013_EN_Kap02.book Seite 57 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277(F) IWLAN
2/58 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
Supply voltage
Supply voltage DC DC DC DC DC
Via charging station Yes Yes Yes Yes Yes
Via table power supply Yes Yes Yes Yes Yes
Processor
Processor ARM, 520 MHz ARM, 520 MHz ARM, 520 MHz ARM, 520 MHz ARM, 520 MHz
Memory
Type Flash / RAM Flash / RAM Flash / RAM Flash / RAM Flash / RAM
Usable memory for user
data 6 MB usable memory
for user data 6 MB usable memory
for user data 6 MB usable memory
for user data 6 MB usable memory
for user data 6 MB usable memory
for user data
Battery
Main battery
Rated voltage 7.2 V 7.2 V 7.2 V 7.2 V 7.2 V
• Capacity 5100mA·h 5 100 mA·h 5100mA·h 5100mA·h 5100mA·h
Number of loading
cycles, min 500 500 500 500 500
Charging time, typ. 4h 4h 4h 4h 4h
Operating time, typ. 4h 4h 4h 4h 4h
Display for battery
capacity Yes Yes Yes Yes Yes
Energy-saving mode Yes Yes Yes Yes Yes
Battery replacement
during operation Yes Yes Yes Yes Yes
Type of output
Status LEDs Yes Yes Yes Yes Yes
LED for safe Yes Yes Yes
LED for communication Yes Yes Yes Yes Yes
LED for battery Yes Yes Yes Yes Yes
Vibrations Yes Yes Yes Yes Yes
Time of day
Clock
• Type Hardware clock, battery
backup, synchronizable Hardware clock, battery
backup, synchronizable Hardware clock, battery
backup, synchronizable Hardware clock, battery
backup, synchronizable Hardware clock, battery
backup, synchronizable
Interfaces
Interfaces 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45)
USB port 1 x USB 1 x USB 1 x USB 1 x USB 1 x USB
Multi Media Card slot 1 MMC/SD card slot 1 MMC/SD card slot 1 MMC/SD card slot 1 MMC/SD card slot 1 MMC/SD card slot
Industrial Ethernet
Industrial Ethernet
interface 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45)
WLAN
• Wireless LAN Yes Yes Yes Yes Yes
Supports rapid roaming Yes Yes Yes Yes Yes
Protocols
PROFINET Yes Yes Yes Yes Yes
Supports protocol for
PROFINET IO Yes Yes Yes Yes Yes
Supports protocol for
PROFIsafe Yes Yes Yes
6AV6645-0DD01-0AX1 6AV6645-0DE01-0AX1 6AV6645-0EB01-0AX1 6AV6645-0EC01-0AX1 6AV6645-0EF01-0AX1
RFID TAG
with integrated
handwheel,
keyoperated switch
and two illuminated
pushbuttons
with integrated
acknowledgement
button and emergency
stop button
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
ST80_2013_EN_Kap02.book Seite 58 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277(F) IWLAN
2/59
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
EMC
Emission of radio interfer-
ence acc. to EN 55 011
Emission of radio
interferences acc. to
EN 55 011 (limit class A)
Yes; The product is
designed for use in
industrial environments.
When used in residen-
tial areas, the emission
of radio interference
according to limit class
B of EN 55011 must be
ensured. For further
information refer to the
user documentation
Yes; The product is
designed for use in
industrial environments.
When used in residen-
tial areas, the emission
of radio interference
according to limit class
B of EN 55011 must be
ensured. For further
information refer to the
user documentation
Yes; The product is
designed for use in
industrial environments.
When used in residen-
tial areas, the emission
of radio interference
according to limit class
B of EN 55011 must be
ensured. For further
information refer to the
user documentation
Yes; The product is
designed for use in
industrial environments.
When used in residen-
tial areas, the emission
of radio interference
according to limit class
B of EN 55011 must be
ensured. For further
information refer to the
user documentation
Yes; The product is
designed for use in
industrial environments.
When used in residen-
tial areas, the emission
of radio interference
according to limit class
B of EN 55011 must be
ensured. For further
information refer to the
user documentation
Degree and class of
protection
IP65 enclosure Yes Yes Yes Yes Yes
Standards, approvals,
certificates
Certifications CE, cULus, C-TICK CE, cULus, C-TICK CE, cULus, C-TICK CE, cULus, C-TICK CE, cULus, C-TICK
TÜV safety certification Yes Yes Yes
Safety category according
to EN954-1 Safety category accord-
ing to EN954-1
(enabling button, STOP
button if present) 4
Safety category accord-
ing to EN954-1
(enabling button, STOP
button if present) 4
Safety category accord-
ing to EN954-1
(enabling button, STOP
button if present) 4
Highest safety class
achievable in safety mode
Performance Level in
accordance with
EN ISO 13849-1
eee
Ambient conditions
Drop height 1.2 m 1.2 m 1.2 m 1.2 m 1.2 m
Operating temperature
•Operation 0 °C to +40 °C 0 °C to +40 °C 0 °C to +40 °C 0 °C to +40 °C 0 °C to +40 °C
Storage/transport
temperature
Transport, storage -20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C
Relative humidity
max. relative humidity 80 % 80 % 80 % 80 % 80 %
Operating systems
Operating system Windows CE Windows CE Windows CE Windows CE Windows CE
Languages
Online languages
Number of online/run-
time languages 16 16 16 16 16
Functionality under
WinCC (TIA Portal)
Libraries Yes Yes Yes Yes Yes
Task planner Yes Yes Yes Yes Yes
With alarm logging system
(incl. buffer and acknowl-
edgment)
Number of messages 4000 4 000 4000 4000 4000
Bit messages Yes Yes Yes Yes Yes
Analog messages Yes Yes Yes Yes Yes
Recipes
Number of recipes 300 300 300 300 300
Data records per recipe 500 500 500 500 500
Entries per data record 1000 1 000 1000 1000 1000
Recipe memory 64 KB integrated Flash,
expandable 64 KB integrated Flash,
expandable 64 KB integrated Flash,
expandable 64 KB integrated Flash,
expandable 64 KB integrated Flash,
expandable
6AV6645-0DD01-0AX1 6AV6645-0DE01-0AX1 6AV6645-0EB01-0AX1 6AV6645-0EC01-0AX1 6AV6645-0EF01-0AX1
RFID TAG
with integrated
handwheel,
keyoperated switch
and two illuminated
pushbuttons
with integrated
acknowledgement
button and emergency
stop button
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
ST80_2013_EN_Kap02.book Seite 59 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277(F) IWLAN
2/60 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
Variables
Number of variables
per device 2048 2 048 2048 2048 2048
• Limit values Yes Yes Yes Yes Yes
• Multiplexing Yes Yes Yes Yes Yes
Images
Number of configurable
images 500 500 500 500 500
Image objects
Text objects 10,000 text elements 10,000 text elements 10,000 text elements 10,000 text elements 10,000 text elements
Graphics object Bit maps, icons, vector
graphics Bit maps, icons, vector
graphics Bit maps, icons, vector
graphics Bit maps, icons, vector
graphics Bit maps, icons, vector
graphics
Complex image objects
Status/control With SIMATIC S7 With SIMATIC S7 With SIMATIC S7 With SIMATIC S7 With SIMATIC S7
dynamic objects Diagrams, bar graphs,
sliders, analog display,
invisible buttons
Diagrams, bar graphs,
sliders, analog display,
invisible buttons
Diagrams, bar graphs,
sliders, analog display,
invisible buttons
Diagrams, bar graphs,
sliders, analog display,
invisible buttons
Diagrams, bar graphs,
sliders, analog display,
invisible buttons
Lists
Number of text lists
per project 500 500 500 500 500
Number of graphics lists
per project 400 400 400 400 400
Archiving
Number of archives
per device 20 20 20 20 20
Number of measuring
points per project 20 20 20 20 20
Number of entries
per archive 10 000 10 000 10 000 10 000 10 000
Security
Number of user groups 50 50 50 50 50
Number of user rights 32 32 32 32 32
Password export/import Yes Yes Yes Yes Yes
Logging through printer
• Recording/Printing Alarms, report (shift
report), PROFINET Alarms, report (shift
report), PROFINET Alarms, report (shift
report), PROFINET Alarms, report (shift
report), PROFINET Alarms, report (shift
report), PROFINET
Transfer
(upload/download)
Transfer of configuration USB, Ethernet, auto-
matic transfer recogni-
tion
USB, Ethernet, auto-
matic transfer recogni-
tion
USB, Ethernet, auto-
matic transfer recogni-
tion
USB, Ethernet, auto-
matic transfer recogni-
tion
USB, Ethernet, auto-
matic transfer recogni-
tion
• Wireless LAN Yes Yes Yes Yes Yes
6AV6645-0DD01-0AX1 6AV6645-0DE01-0AX1 6AV6645-0EB01-0AX1 6AV6645-0EC01-0AX1 6AV6645-0EF01-0AX1
RFID TAG
with integrated
handwheel,
keyoperated switch
and two illuminated
pushbuttons
with integrated
acknowledgement
button and emergency
stop button
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
ST80_2013_EN_Kap02.book Seite 60 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277(F) IWLAN
2/61
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
Process coupling
Connection to controller S7-200, S7- 300/400
see section on "System
interfaces"
S7-200, S7- 300/400
see section on "System
interfaces"
S7-200, S7- 300/400
see section on "System
interfaces"
S7-200, S7- 300/400
see section on "System
interfaces"
S7-200, S7- 300/400
see section on "System
interfaces"
• S7-1200 Yes Yes No No No
• S7-1500 Yes Yes No No No
• Zones Yes Yes Yes Yes
- Number of zones
per project, max. 254 254 254 254
- Number of transpon-
ders for zones per
project, max.
255 255 255 255
Effective range Yes Yes Yes
- Number of effective
ranges per project,
max.
127 127 127
-Number of
transponders for
effective ranges per
project, max.
127 127
• Transponder Yes Yes Yes Yes
- Number of transpon-
ders per project, max. 256 256 256 256
- Adjustable distance
range Yes Yes Yes Yes
- Adjustable distance,
min. 2m 2m 2m 2m
- Adjustable distance,
max. 8m 8m 8m 8m
I/O
I/O devices Barcode reader Barcode reader Barcode reader Barcode reader Barcode reader
Multi Media Card Yes Yes Yes Yes Yes
Mechanics/material
Type of housing (front) Plastic Plastic Plastic Plastic Plastic
Dimensions
Housing diameter/depth
(mm) Dia 290 mm / D 103 mm Dia 290 mm / D 103 mm Dia 290 mm / D 103 mm Dia 290 mm / D 103 mm Dia 290 mm / D 103 mm
Weight
Weight 2.2 kg 2.2 kg 2.2 kg 2.2 kg 2.2 kg
6AV6645-0DD01-0AX1 6AV6645-0DE01-0AX1 6AV6645-0EB01-0AX1 6AV6645-0EC01-0AX1 6AV6645-0EF01-0AX1
RFID TAG
with integrated
handwheel,
keyoperated switch
and two illuminated
pushbuttons
with integrated
acknowledgement
button and emergency
stop button
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
ST80_2013_EN_Kap02.book Seite 61 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277(F) IWLAN
2/62 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
6AV6645-0FD01-0AX1 6AV6645-0FE01-0AX1 6AV6645-0GB01-0AX1 6AV6645-0GC01-0AX1 6AV6645-0GF01-0AX1
USA version USA version
with handwheel,
keyoperated switch
and two illuminated
pushbuttons
USA version
with integrated
acknowledgement
button and emergency
stop button
USA version
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
USA version
RFID TAG
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
Display
Size 7.5" 7.5" 7.5" 7.5" 7.5"
Display type TFT, 65536 colors TFT, 65536 colors TFT, 65536 colors TFT, 65536 colors TFT, 65536 colors
Resolution (pixels)
Resolution (WxH in pixel) 640 x 480 640 x 480 640 x 480 640 x 480 640 x 480
Backlighting
MTBF backlighting
(at 25 °C) about 50,000 hours about 50,000 hours about 50,000 hours about 50,000 hours about 50,000 hours
MTBF backlighting
(at 25 °C) 50 000 h 50 000 h 50 000 h 50 000 h
Control elements
Operating options Keys and Touch Keys and Touch Keys and Touch Keys and Touch Keys and Touch
Function keys,
programmable 18 function keys,
18 with LEDs 18 function keys,
18 with LEDs 18 function keys,
18 with LEDs 18 function keys,
18 with LEDs 18 function keys,
18 with LEDs
Connection for mouse/
keyboard/barcode reader USB / USB / USB USB / USB / USB USB / USB / USB USB / USB / USB USB / USB / USB
Touch operation
Touch screen Analog, resistive Analog, resistive Analog, resistive Analog, resistive Analog, resistive
Special operator controls
Stop button No No Yes Yes Yes
• Acknowledgement
button No No Yes Yes Yes
Key-operated switch No Yes No Yes Yes
Illuminated pushbutton No Yes No Yes Yes
• Handwheel No Yes No Yes Yes
Supply voltage
Supply voltage DC DC DC DC DC
Via charging station Yes Yes Yes Yes Yes
Via table power supply Yes Yes Yes Yes Yes
Processor
Processor ARM, 520 MHz ARM, 520 MHz ARM, 520 MHz ARM, 520 MHz ARM, 520 MHz
Memory
Type Flash / RAM Flash / RAM Flash / RAM Flash / RAM Flash / RAM
Usable memory for user
data 6 MB usable memory
for user data 6 MB usable memory
for user data 6 MB usable memory
for user data 6 MB usable memory
for user data 6 MB usable memory
for user data
Battery
Main battery
Rated voltage 7.2 V 7.2 V 7.2 V 7.2 V 7.2 V
• Capacity 5100mA·h 5 100 mA·h 5100mA·h 5100mA·h 5100mA·h
Number of loading
cycles, min 500 500 500 500 500
Charging time, typ. 4h 4h 4h 4h 4h
Operating time, typ. 4h 4h 4h 4h 4h
Display for battery
capacity Yes Yes Yes Yes Yes
Energy-saving mode Yes Yes Yes Yes Yes
Battery replacement
during operation Yes Yes Yes Yes Yes
ST80_2013_EN_Kap02.book Seite 62 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277(F) IWLAN
2/63
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
Type of output
Status LEDs Yes Yes Yes Yes Yes
LED for safe Yes Yes Yes
LED for communication Yes Yes Yes Yes Yes
LED for battery Yes Yes Yes Yes Yes
Vibrations Yes Yes Yes Yes Yes
Time of day
Clock
• Type Hardware clock, battery
backup, synchronizable Hardware clock, battery
backup, synchronizable Hardware clock, battery
backup, synchronizable Hardware clock, battery
backup, synchronizable Hardware clock, battery
backup, synchronizable
Interfaces
Interfaces 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45)
USB port 1 x USB 1 x USB 1 x USB 1 x USB 1 x USB
Multi Media Card slot 1 MMC/SD card slot 1 MMC/SD card slot 1 MMC/SD card slot 1 MMC/SD card slot 1 MMC/SD card slot
Industrial Ethernet
Industrial Ethernet
interface 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45) 1 x Ethernet (RJ45)
WLAN
• Wireless LAN Yes Yes Yes Yes Yes
Supports rapid roaming Yes Yes Yes Yes Yes
Protocols
PROFINET Yes Yes Yes Yes Yes
Supports protocol for
PROFINET IO Yes Yes Yes Yes Yes
Supports protocol for
PROFIsafe Yes Yes Yes
EMC
Emission of radio interfer-
ence acc. to EN 55 011
Emission of radio
interferences acc. to
EN 55 011 (limit class A)
Yes; The product is
designed for use in
industrial environments.
When used in residen-
tial areas, the emission
of radio interference
according to limit class
B of EN 55011 must be
ensured. For further
information refer to the
user documentation
Yes; The product is
designed for use in
industrial environments.
When used in residen-
tial areas, the emission
of radio interference
according to limit class
B of EN 55011 must be
ensured. For further
information refer to the
user documentation
Yes; The product is
designed for use in
industrial environments.
When used in residen-
tial areas, the emission
of radio interference
according to limit class
B of EN 55011 must be
ensured. For further
information refer to the
user documentation
Yes; The product is
designed for use in
industrial environments.
When used in residen-
tial areas, the emission
of radio interference
according to limit class
B of EN 55011 must be
ensured. For further
information refer to the
user documentation
Yes; The product is
designed for use in
industrial environments.
When used in residen-
tial areas, the emission
of radio interference
according to limit class
B of EN 55011 must be
ensured. For further
information refer to the
user documentation
6AV6645-0FD01-0AX1 6AV6645-0FE01-0AX1 6AV6645-0GB01-0AX1 6AV6645-0GC01-0AX1 6AV6645-0GF01-0AX1
USA version USA version
with handwheel,
keyoperated switch
and two illuminated
pushbuttons
USA version
with integrated
acknowledgement
button and emergency
stop button
USA version
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
USA version
RFID TAG
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
ST80_2013_EN_Kap02.book Seite 63 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277(F) IWLAN
2/64 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
Degree and class of
protection
IP65 enclosure Yes Yes Yes Yes Yes
Standards, approvals,
certificates
Certifications CE, cULus, C-TICK CE, cULus, C-TICK CE, cULus, C-TICK CE, cULus, C-TICK CE, cULus, C-TICK
TÜV safety certification Yes Yes Yes
Safety category according
to EN954-1 Safety category
according to EN954-1
(enabling button, STOP
button if present) 4
Safety category
according to EN954-1
(enabling button, STOP
button if present) 4
Safety category
according to EN954-1
(enabling button, STOP
button if present) 4
Highest safety class
achievable in safety mode
Performance Level in
accordance with
EN ISO 13849-1
eee
Ambient conditions
Drop height 1.2 m 1.2 m 1.2 m 1.2 m 1.2 m
Operating temperature
•Operation 0 °C to +40 °C 0 °C to +40 °C 0 °C to +40 °C 0 °C to +40 °C 0 °C to +40 °C
Storage/transport temper-
ature
Transport, storage -20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C -20 °C to +60 °C
Relative humidity
max. relative humidity 80 % 80 % 80 % 80 % 80 %
Operating systems
Operating system Windows CE Windows CE Windows CE Windows CE Windows CE
Languages
Online languages
Number of online/
runtime languages 16 16 16 16 16
Functionality under
WinCC (TIA Portal)
Libraries Yes Yes Yes Yes Yes
Task planner Yes Yes Yes Yes Yes
With alarm logging system
(incl. buffer and acknowl-
edgment)
Number of messages 4000 4 000 4000 4000 4000
Bit messages Yes Yes Yes Yes Yes
Analog messages Yes Yes Yes Yes Yes
Recipes
Number of recipes 300 300 300 300 300
Data records per recipe 500 500 500 500 500
Entries per data record 1000 1 000 1000 1000 1000
Recipe memory 64 KB integrated Flash,
expandable 64 KB integrated Flash,
expandable 64 KB integrated Flash,
expandable 64 KB integrated Flash,
expandable 64 KB integrated Flash,
expandable
6AV6645-0FD01-0AX1 6AV6645-0FE01-0AX1 6AV6645-0GB01-0AX1 6AV6645-0GC01-0AX1 6AV6645-0GF01-0AX1
USA version USA version
with handwheel,
keyoperated switch
and two illuminated
pushbuttons
USA version
with integrated
acknowledgement
button and emergency
stop button
USA version
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
USA version
RFID TAG
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
ST80_2013_EN_Kap02.book Seite 64 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277(F) IWLAN
2/65
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
Variables
Number of variables per
device 2048 2 048 2048 2048 2048
• Limit values Yes Yes Yes Yes Yes
• Multiplexing Yes Yes Yes Yes Yes
Images
Number of configurable
images 500 500 500 500 500
Image objects
Text objects 10,000 text elements 10,000 text elements 10,000 text elements 10,000 text elements 10,000 text elements
Graphics object Bit maps, icons, vector
graphics Bit maps, icons, vector
graphics Bit maps, icons, vector
graphics Bit maps, icons, vector
graphics Bit maps, icons, vector
graphics
Complex image objects
Status/control With SIMATIC S7 With SIMATIC S7 With SIMATIC S7 With SIMATIC S7 With SIMATIC S7
dynamic objects Diagrams, bar graphs,
sliders, analog display,
invisible buttons
Diagrams, bar graphs,
sliders, analog display,
invisible buttons
Diagrams, bar graphs,
sliders, analog display,
invisible buttons
Diagrams, bar graphs,
sliders, analog display,
invisible buttons
Diagrams, bar graphs,
sliders, analog display,
invisible buttons
Lists
Number of text lists per
project 500 500 500 500 500
Number of graphics lists
per project 400 400 400 400 400
Archiving
Number of archives per
device 20 20 20 20 20
Number of measuring
points per project 20 20 20 20 20
Number of entries per
archive 10 000 10 000 10 000 10 000 10 000
Security
Number of user groups 50 50 50 50 50
Number of user rights 32 32 32 32 32
Password export/import Yes Yes Yes Yes Yes
Logging through printer
• Recording/Printing Alarms, report (shift
report), PROFINET Alarms, report (shift
report), PROFINET Alarms, report (shift
report), PROFINET Alarms, report (shift
report), PROFINET Alarms, report (shift
report), PROFINET
Transfer
(upload/download)
Transfer of configuration USB, Ethernet, auto-
matic transfer recogni-
tion
USB, Ethernet, auto-
matic transfer recogni-
tion
USB, Ethernet, auto-
matic transfer recogni-
tion
USB, Ethernet, auto-
matic transfer recogni-
tion
USB, Ethernet, auto-
matic transfer recogni-
tion
• Wireless LAN Yes Yes Yes Yes Yes
6AV6645-0FD01-0AX1 6AV6645-0FE01-0AX1 6AV6645-0GB01-0AX1 6AV6645-0GC01-0AX1 6AV6645-0GF01-0AX1
USA version USA version
with handwheel,
keyoperated switch
and two illuminated
pushbuttons
USA version
with integrated
acknowledgement
button and emergency
stop button
USA version
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
USA version
RFID TAG
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
ST80_2013_EN_Kap02.book Seite 65 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277(F) IWLAN
2/66 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
Process coupling
Connection to controller S7-200, S7- 300/400
see section on "System
interfaces"
S7-200, S7- 300/400
see section on "System
interfaces"
S7-200, S7- 300/400
see section on "System
interfaces"
S7-200, S7- 300/400
see section on "System
interfaces"
S7-200, S7- 300/400
see section on "System
interfaces"
• S7-1200 Yes Yes No No No
• S7-1500 Yes Yes No No No
• Zones Yes Yes Yes Yes
- Number of zones per
project, max. 254 254 254 254
-Number of
transponders for zones
per project, max.
255 255 255 255
Effective range Yes Yes Yes
- Number of effective
ranges per project,
max.
127 127 127
-Number of
transponders for
effective ranges per
project, max.
127 127
• Transponder Yes Yes Yes Yes
- Number of transpon-
ders per project, max. 256 256 256 256
- Adjustable distance
range Yes Yes Yes Yes
- Adjustable distance,
min. 2m 2m 2m 2m
- Adjustable distance,
max. 8m 8m 8m 8m
I/O
I/O devices Barcode reader Barcode reader Barcode reader Barcode reader Barcode reader
Multi Media Card Yes Yes Yes Yes Yes
Mechanics/material
Type of housing (front) Plastic Plastic Plastic Plastic Plastic
Dimensions
Housing diameter/depth
(mm) Dia 290 mm / D 103 mm Dia 290 mm / D 103 mm Dia 290 mm / D 103 mm Dia 290 mm / D 103 mm Dia 290 mm / D 103 mm
Weight
Weight 2.2 kg 2.2 kg 2.2 kg 2.2 kg 2.2 kg
6AV6645-0FD01-0AX1 6AV6645-0FE01-0AX1 6AV6645-0GB01-0AX1 6AV6645-0GC01-0AX1 6AV6645-0GF01-0AX1
USA version USA version
with handwheel,
keyoperated switch
and two illuminated
pushbuttons
USA version
with integrated
acknowledgement
button and emergency
stop button
USA version
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
USA version
RFID TAG
with integrated
acknowledgement
button and emergency
stop button,
handwheel,
key-operated switch,
and two illuminated
pushbuttons
ST80_2013_EN_Kap02.book Seite 66 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277(F) IWLAN
2/67
Siemens ST 80 / ST PC · 2013
2
Ordering data Order No. Order No.
1) RoW version: "Rest of World" version:
Version for worldwide sales except in the U.S.
2) Already prepared for Rapid Roaming (iPCF-MC). iPCF-MC is already
included from SCALANCE FW version V4.3.37 and higher.
For national approvals see:
http://www.siemens.com/wireless-approvals
The Function Manuals "Fail-Safe Operation of the Mobile Panel
277F IWLAN V1" are available for downloading in English,
German, and Japanese.
http://support.automation.siemens.com/WW/view/en/31255853
SIMATIC Mobile Panel 277
IWLAN V2 (RoW version 1))
Communication via WLAN
(PROFINET) 6AV6645-0DD01-0AX1
Communication via WLAN
(PROFINET)
with integrated handwheel,
key-operated switch and
two illuminated pushbuttons
6AV6645-0DE01-0AX1
SIMATIC Mobile Panel 277F
IWLAN V2 PROFIsafe
(RoW version 1))
Communication via WLAN
(PROFINET)
with acknowledgement button and
emergency stop button
6AV6645-0EB01-0AX1
Communication via WLAN
(PROFINET)
with acknowledgement button and
emergency stop button with inte-
grated handwheel, key-operated
switch, and two illuminated push-
buttons
6AV6645-0EC01-0AX1
RFID tag version: Communication
via WLAN (PROFINET) with ac-
knowledgement button and emer-
gency stop button with integrated
handwheel, key-operated switch,
and two illuminated pushbuttons
6AV6645-0EF01-0AX1
SIMATIC Mobile Panel 277
IWLAN V2 (USA version)
Communication via WLAN
(PROFINET) 6AV6645-0FD01-0AX1
Communication via WLAN
(PROFINET)
with integrated handwheel,
key-operated switch and
two illuminated pushbuttons
6AV6645-0FE01-0AX1
SIMATIC Mobile Panel 277F
IWLAN V2 PROFIsafe
(USA version)
with acknowledgement button and
emergency stop button 6AV6645-0GB01-0AX1
with acknowledgement button and
emergency stop button with inte-
grated handwheel, key-operated
switch, and two illuminated push-
buttons
6AV6645-0GC01-0AX1
with acknowledgement button and
emergency stop button with inte-
grated handwheel, key-operated
switch, and two illuminated push-
buttons (tag version)
6AV6645-0GF01-0AX1
Starter kit
SIMATIC Mobile Panel 277(F)
IWLAN (RoW version1))
for
Mobile Panel 277 IWLAN V2 6AV6651-5GA01-0AA1
Mobile Panel 277F IWLAN V2 6AV6651-5HA01-0AA1
Accessories See HMI accessories,
from page 2/99
Note:
Please order the table-top power
supply or charging station as well.
Required for charging the battery.
Documentation
You can find the manuals for the
Mobile Panels on the Internet at:
http://support.automation.sie-
mens.com/WW/view/en/11599011/
133300
SIMATIC HMI Manual Collection 6AV6691-1SA01-0AX0
Electronic documentation on DVD,
5 languages (English, German,
French, Italian and Spanish);
contains: all currently available user
manuals, device manuals and com-
munication manuals for
SIMATIC HMI
ST80_2013_EN_Kap02.book Seite 67 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Mobile Panels — 270 series
SIMATIC Mobile Panel 277(F) IWLAN
2/68 Siemens ST 80 / ST PC · 2013
2
Dimensional drawings
All dimensions in mm. For installation cutout, see technical
specifications.
Mobile Panel 277(F) IWLAN, front and side view
More information
Additional information is available in the Internet under:
http://www.siemens.com/simatic-mobile-panels
Note
Do you need a specific modification or addition to the products
described here? Then take a look under "Customer-specific
products". There, you will find information on ordering additional
and standard industry products as well as possibilities for
customer-specific modifications and adjustments.
103 mm
129 mm
ø 290 mm
155
117
9
G_ST80_XX_00299
ST80_2013_EN_Kap02.book Seite 68 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
System components
System components for Mobile Panels
2/69
Siemens ST 80 / ST PC · 2013
2
Overview
System components for Mobile Panels are perfectly matched
to the SIMATIC HMI Mobile Panels. Charging stations,
transponders, and diverse connection boxes are available for
various applications.
Accessories for SIMATIC HMI Mobile Panels can be found under
"SIMATIC HMI accessories".
Only the latest SIMATIC HMI accessories are listed in this
section; the full range of SIMATIC HMI accessories is available
in the Mall and in our other online media.
ST80_2013_EN_Kap02.book Seite 69 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
System components
Terminal boxes
2/70 Siemens ST 80 / ST PC · 2013
2
Overview
Technical specifications
6AV6671-5AE00-0AX0 6AV6671-5AE10-0AX0 6AV6671-5AE01-0AX0 6AV6671-5AE11-0AX0
DP connection box for
Mobile Panel 177/277
(MPI/PROFIBUS) Basic
DP connection box for
Mobile Panel 177/277
(MPI/PROFIBUS) Plus
PN connection box for
Mobile Panel 177/277
(PROFINET) Basic
PN connection box for
Mobile Panel 177/277
(PROFINET) Plus
Control elements
Expansions for operator control
of the process
Hot swapping with emergency stop circuit
interruption without emergency stop
circuit interruption with emergency stop circuit
interruption without emergency stop
circuit interruption
- without emergency stop
circuit interruption No Yes No Yes
- with emergency stop circuit
interruption Yes No Yes No
- Monitoring the STOP button No Yes No Yes
- Location identifier Yes Yes Yes Yes
Supply voltage
Type of actuation DC DC DC DC
•AC No No No No
•DC Yes Yes Yes Yes
Rated voltage 24 V 24 V 24 V 24 V
permissible range +20.4 V to +28.8 V DC +20.4 V to +28.8 V DC +20.4 V to +28.8 V DC +20.4 V to +28.8 V DC
Supply voltage range 20.4 V 20.4 V 20.4 V 20.4 V
Supply voltage range 28.8 V 28.8 V 28.8 V 28.8 V
Supply voltage 24 V DC 24 V DC 24 V DC 24 V DC
Input current
Rated current 0.4 A 0.5 A 0.4 A 0.5 A
Power
Power 10 W 12 W 10 W 12 W
Interfaces
Interfaces 1 x RS232, 1 x RS422,
1 x RS485 (max. 12 Mbit/s) 1 x RS232, 1 x RS422,
1 x RS485 (max. 12 Mbit/s) 2 x Ethernet (RJ45) 2 x Ethernet (RJ45)
Number of 20 mA interfaces
(TTY) 0 0
Number of RS 232 interfaces 1 1
Number of RS 422 interfaces 1 1
Industrial Ethernet
Industrial Ethernet interface 2 x Ethernet (RJ45) 2 x Ethernet (RJ45)
Industrial Ethernet status LED 6 6
ST80_2013_EN_Kap02.book Seite 70 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
System components
Terminal boxes
2/71
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
Degree and class of
protection
Enclosure according to
EN 60529 IP65 IP65 IP65 IP65
IP20 housing No No No No
IP54 housing No No No No
IP65 enclosure Yes Yes Yes Yes
NEMA 4 No No No No
NEMA 4X No No No No
NEMA 12 No No No No
Standards, approvals,
certificates
Certifications CE, cULus, C-TICK CE, cULus, C-TICK CE, cULus, C-TICK CE, cULus, C-TICK
CE Yes Yes Yes Yes
CSA No No No No
UL No No No No
FM Class I Div. 2 No No No No
GL No No No No
ABS No No No No
BV No No No No
DNV No No No No
LRS No No No No
PRS No No No No
Gost-R No No No No
Use in hazardous areas
EX zone 2 No No No No
EX zone 22 No No No No
Ambient conditions
Operating temperature
•Operation
(vertical installation) 0 °C to +50 °C 0 °C to +50 °C 0 °C to +50 °C 0 °C to +50 °C
- in vertical mounting
position/ minimum C 0°C C 0°C
- in vertical mounting
position/ maximum 50 °C 50 °C 50 °C 50 °C
Storage/transport temperature
Ambient temperature
during storage, minimum -20 °C -20 °C -20 °C -20 °C
Ambient temperature
during storage, maximal 70 °C 70 °C 70 °C 70 °C
Transport, storage -20 °C to +70 °C -20 °C to +70 °C -20 °C to +70 °C -20 °C to +70 °C
Relative humidity
max. relative humidity 85 % 85 % 85 % 85 %
Functionality under WinCC
(TIA Portal)
Applications/options
Connection point
identification Yes Yes Yes Yes
Dimensions
External dimensions
(W x H x D) in mm 160 x 120 x 70 160 x 120 x 70 230 x 120 x 80 230 x 120 x 80
•Width 160 160 230 230
•Height 120 120 120 120
•Depth 70 70 80 80
Weight
Weight 0.35 kg 0.4 kg 0.45 kg 0.5 kg
other
free hotline Yes Yes Yes Yes
Warranty period 1a 1a 1a 1a
6AV6671-5AE00-0AX0 6AV6671-5AE10-0AX0 6AV6671-5AE01-0AX0 6AV6671-5AE11-0AX0
DP connection box for
Mobile Panel 177/277
(MPI/PROFIBUS) Basic
DP connection box for
Mobile Panel 177/277
(MPI/PROFIBUS) Plus
PN connection box for
Mobile Panel 177/277
(PROFINET) Basic
PN connection box for
Mobile Panel 177/277
(PROFINET) Plus
ST80_2013_EN_Kap02.book Seite 71 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
System components
Terminal boxes
2/72 Siemens ST 80 / ST PC · 2013
2
Ordering data Order No.
Dimensional drawings
All dimensions in mm. For installation cutout, see technical
specifications.
DP connection box for SIMATIC Mobile Panel
PN connection box for SIMATIC Mobile Panel
DP connection box
for Mobile Panels 177/277
(MPI/PROFIBUS)
•Basic 6AV6671-5AE00-0AX0
•Plus 6AV6671-5AE10-0AX0
PN connection box
for Mobile Panels 177/277
(PROFINET)
•Basic 6AV6671-5AE01-0AX0
•Plus 6AV6671-5AE11-0AX0
±
62.7
G_ST80_XX_00045
43
140
10
160
150
11 0
120
142 2
210
10
76 120
142 ± 2
110
4.5
55
230
220
G_ST80_XX_00273
ST80_2013_EN_Kap02.book Seite 72 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
System components
SIPLUS connection boxes
2/73
Siemens ST 80 / ST PC · 2013
2
Overview
Note:
SIPLUS extreme products are based on Siemens Industry
standard products. The contents listed here were taken from the
respective standard products. SIPLUS extreme-specific infor-
mation was added.
Ordering data Order No.
SIPLUS connection box DP Plus
Order number 6AG1 671-5AE10-4AX0
Order number based on 6AV6 671-5AE10-0AX0
Ambient temperature range 0 ... +50 °C
Conformal coating Coating of the printed circuit boards
and the electronic components
Technical data The technical data of the standard
product applies except for the
ambient conditions.
Ambient conditions
Relative humidity 100%, condensation/frost
permissible. No commissioning
if condensation present.
Air pressure
(depending on the highest positive
temperature range specified)
1080 ... 795 hPa (-1000 ... +2000m)
see ambient temperature range
795 ... 658 hPa (+2000 ... +3500m)
derating 10 K
658 … 540 hPa (+3500 … +5000m)
derating 20 K
SIPLUS connection box DP Plus
for Mobile Panels 177/277
(MPI/PROFIBUS)
6AG1671-5AE10-4AX0
ST80_2013_EN_Kap02.book Seite 73 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
System components
Charging station
2/74 Siemens ST 80 / ST PC · 2013
2
Overview
Technical specifications
Ordering data Order No.
Dimensional drawings
All dimensions in mm. For installation cutout, see technical
specifications.
6AV6671-5CE00-0AX1
Supply voltage
Type of actuation DC
•DC Yes
Rated voltage 24 V
permissible range +19.2 V to +28.8 V DC
Supply voltage range 19.2 V
Supply voltage range 28.8 V
Supply voltage 24 V DC
Input current
Rated current 3.2 A
Power
Power 77 W
Degree and class of protection
Enclosure according to EN 60529 IP65
IP65 enclosure Yes
Standards, approvals, certificates
Certifications CE, cULus, C-TICK
CE Yes
Ambient conditions
Operating temperature
Operation (vertical installation) 0 °C to +40 °C
- in vertical mounting position/
minimum C
- in vertical mounting position/
maximum 40 °C
Storage/transport temperature
Ambient temperature during storage,
minimum -20 °C
Ambient temperature during storage,
maximal 60 °C
Transport, storage -20 °C to +60 °C
Relative humidity
max. relative humidity 85 %
Dimensions
External dimensions
(W x H x D) in mm 208 x 333 x 75
•Width 208
•Height 333
•Depth 75
Weight
Weight 1.1 kg
Charging station for
Mobile Panels 6AV6671-5CE00-0AX1
160
208 72
343
198
61 85
G_ST80_XX_00297
ST80_2013_EN_Kap02.book Seite 74 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
System components
Transponder
2/75
Siemens ST 80 / ST PC · 2013
2
Overview
Technical specifications
Ordering data Order No.
Dimensional drawings
All dimensions in mm. For installation cutout, see technical
specifications.
6AV6671-5CM00-0AX1
Degree and class of protection
Enclosure according to EN 60529 IP65
IP65 enclosure Yes
Enclosure according to NEMA NEMA 4x, NEMA 12
NEMA 4X Yes
NEMA 12 Yes
Standards, approvals, certificates
Certifications CE, cULus, C-TICK, NEMA 4x,
NEMA 12
CE Yes
Ambient conditions
Operating temperature
Operation (vertical installation) 0 °C to +50 °C
- in vertical mounting position/
minimum C
- in vertical mounting position/
maximum 50 °C
Storage/transport temperature
Ambient temperature during storage,
minimum -20 °C
Ambient temperature during storage,
maximal 60 °C
Transport, storage -20 °C to +60 °C
Relative humidity
max. relative humidity 85 %
Dimensions
External dimensions
(W x H x D) in mm 172 x 90 x 38.5
•Width 172
•Height 90
•Depth 38.5
Weight
Weight 0.3 kg
Transponder for
Mobile Panels 277 6AV6671-5CM00-0AX1
38.5
G_ST80_XX_00298
172
90
162
45
ST80_2013_EN_Kap02.book Seite 75 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
System interfaces with WinCC (TIA Portal)
System interfaces with WinCC (TIA Portal)
2/76 Siemens ST 80 / ST PC · 2013
2
Overview
The SIMATIC Touch Panel (TP), Operator Panel (OP),
Basic Panel, Comfort Panel, Mobile Panel, multifunctional
platforms (MP)1) offer HMI functionality for the control systems:
SIMATIC S7
Non-Siemens controllers:
-Allen Bradley
- Mitsubishi
- Modicon
- Omron
For more detailed information, refer to the WinCC (TIA Portal)
user manual, the "Windows-based systems communication"
manual, or the WinCC (TIA Portal) online help.
OPC communication and HTTP communication are offered for all
Panels with an integrated Ethernet interface. Both OPC and
HTTP communication can be used in parallel with the process
links to SIMATIC S7 or non-Siemens PLCs.
1) For the sake of simplicity, SIMATIC Panel is always used in the text below.
This is not restrictive, as the information is valid for all systems referred to
above. If there are constraints, direct reference is made to them in the text.
Note:
Interface options for HMI devices: See the individual device
descriptions.
OPC communication
OPC Data Access is an open standard for exchanging both local
and remote variables between various applications via Industrial
Ethernet. The original version of OPC is based on Microsoft
COM/DCOM and, therefore, requires a Microsoft Windows-
based PC operating system (not Windows CE) on both clients
and servers. As OPC XML, communication is based on the
Internet standard SOAP/XML and is, therefore, suitable for
embedded systems with Windows CE.
HTTP communication for variable exchange between
SIMATIC HMI systems
Communication based on HTTP message frames enables
variables to be exchanged between SIMATIC HMI systems.
System interface possible
– System interface not possible
1) Only through DCOM/XML gateway in scope of delivery of
WinCC Advanced for access to OPC XML server of the SIMATIC Panel
Communication standard SIMATIC HMI
Version Comfort Panel TP 177B DP/PN
OP 177B DP/PN
Mobile Panel 177 PN
MP 177
TP 277
OP 277
Mobile Panel 277
MP 277
MP 377 WinCC Runtime
Advanced
OPC Data Access V2.05a + OPC UA Data Access V1.01 + OPC Data Access XML V1.00
OPC DA Client
(COM/DCOM) – – –
OPC DA server
(COM/DCOM)
OPC UA client • – –
OPC XML DA client
(SOAP/XML) 1)
OPC XML DA server
(SOAP/XML) • – –
HTTP communication for variable exchange between SIMATIC HMI systems
HTTP client
HTTP server
ST80_2013_EN_Kap02.book Seite 76 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
System interfaces with WinCC (TIA Portal)
SIMATIC S7
2/77
Siemens ST 80 / ST PC · 2013
2
Overview
The following types of interface are differentiated in respect of
the link between the SIMATIC Panels and SIMATIC S7
controllers:
PROFINET interface:
Coupling of SIMATIC Panel to SIMATIC S7 controllers via
Industrial Ethernet TCP/IP using the integrated PROFINET
interface of the CPU or, alternatively, a PROFINET interface
module.
MPI/PROFIBUS interface:
Coupling of SIMATIC Panel to SIMATIC S7 controllers via MPI/
PROFIBUS using the integrated MPI/PROFIBUS interface of
the CPU for S7-300, S7-400 or the integrated PPI interface of
the CPU in the case of S7-200 or, alternatively, a PROFIBUS
interface module in the case of S7-1200, S7-300 and S7-400.
PPI interface:
Coupling of SIMATIC Panel to SIMATIC S7-200 via PPI network
using the integrated PPI interface of the CPU
The maximum possible number of S7 connections of one CPU is
determined by its performance capacity (see Catalog ST 70);
from the point of view of SIMATIC Panel, the following restrictions
apply:
OP 73: max. 2 connections
OP 77A, TP 177A, Basic Panel, OP 77B, TP177B, OP 177B,
Mobile Panel 177: max. 4 connections
Comfort Panel, TP 277, OP 277; Mobile Panel 277, MP 177,
MP 277, MP 377: max. 6 connections
PC with WinCC Runtime Advanced: max. 8 connections
PPI interface
The PPI interface is a point-to-point connection between a
SIMATIC Panel (PPI master) or alternatively a PG (PPI master)
and an S7-200 (PPI slave).
The corresponding multipoint-enabled communication inter-
faces of SIMATIC Panels and SIMATIC S7 are used.
The following are possible:
Interface between one or a number of SIMATIC Panels (MPI
master) and one or a number of S7-1200/300/400s or WinAC
(MPI master).(possible network topology: MPI/PROFIBUS or
Industrial Ethernet, TCP/IP)
Interface between one or a number of SIMATIC Panels
(MPI master) and one or a number of S7-200s (MPI slave)1)
(possible network topology: PPI, MPI/PROFIBUS)
Unlike PPI connections, MPI connections are static connections
that are set up during booting and then monitored.
The original format of a master/master link has been joined by a
master/slave link, which has enabled integration of the S7-200
(except CPU 212).1)
In principle this type of information exchange between SIMATIC
Panels and SIMATIC S7 is independent of the network used, PPI,
MPI/PROFIBUS or Industrial Ethernet: SIMATIC Panels are
S7 clients and SIMATIC S7 CPUs are S7 servers.
1) With regard to restricted baud transmission rates for S7-200,
see Catalog ST 70.
ST80_2013_EN_Kap02.book Seite 77 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
System interfaces with WinCC (TIA Portal)
SIMATIC S7
2/78 Siemens ST 80 / ST PC · 2013
Overview (continued)
2
• System interface possible
System interface not possible
1) Mobile Panel connection via special connecting cable and junction box
(see Mobile Panel), see Manual for cable layout.
2) Controllers can be combined as desired
3) OP 73 can only be interfaced with max. 2 x SIMATIC S7 (MPI);
network operation (parallel PG, etc.) possible
4) Max. transmission rate 1.5 Mbit/s
5) Only Basic Panel PN, TP 177B DP/PN, OP 177B DP/PN,
Mobile Panel 177 PN
6) Not Basic Panel PN, Mobile Panel 177 PN
7) Connection via integrated MPI/PROFIBUS interface; use the CP 5611 A2
with a standard PC
8) Only on passive S7-200; OP 77B also on active S7-200
9) Only OP 77B
10)Can be interfaced via PPI to max. 1 x S7-200 (PPI);
network operation (parallel PG, etc) is possible
Note:
Detailed information regarding cable layout can be found in the
online help for WinCC.
Controller SIMATIC HMI
Target hardware (PROTOCOL)
(physics) OP 73
OP 77A
TP 177A
Basic Panel Comfort Panel OP 77B
TP 177B DP
OP 177B DP
TP 177B DP/PN
OP 177B DP/PN
Mobile Panel 177 DP1)
Mobile Panel 177 PN 1)
TP 277
OP 277
Mobile Panel 277 1)
MP 177
MP 277
MP 377
WinCC Runtime
Advanced
SIMATIC S7-1200 2)
via Ethernet (TCP/IP)
to max. 4 x S7-1200 5) 5) • •
via MPI or PROFIBUS network
to max. 4 x S7-1200 with
PROFIBUS module (DP-Master)
CM 1243-5
3) 4) 6) • •5) 7)
SIMATIC S7-300, -400, Win AC 2)
via Ethernet (TCP/IP)
to max. 4 x S7-300, -400,
WinAC
5) 5) • •
via MPI or PROFIBUS network
to up to 4 x S7-300, S7-400,
WinAC
3) 4) 6) 6) 7)
SIMATIC S7-200 2)
via Ethernet (TCP/IP)
(MPI protocol)
to max. 4 x S7-200
5) 5) • •
via MPI or PROFIBUS network
(MPI protocol)
to up to 4 x S7-200
3) 4) 6) 8) 6) 8) 8) 7) 8)
via PPI network
(MPI protocol)
to up to 4 x S7-200
3) 4) 6) 9) – –
via PPI network
(PPI protocol)
to max. 1 x S7-200
––10) 10) 10) 7)10)
ST80_2013_EN_Kap02.book Seite 78 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
System interfaces with WinCC (TIA Portal)
Controllers from other manufacturers
2/79
Siemens ST 80 / ST PC · 2013
2
Overview
The SIMATIC Touch Panel (TP), Operator Panel (OP), Basic
Panel, Comfort Panel, Mobile Panel, multifunctional platforms
(MP) and the SIMATIC HMI software package for PC WinCC
Runtime Advanced support the following protocols for the linking
of control systems from other manufacturers:
Allen Bradley
- Ethernet IP protocol
- DF1 protocol
• Mitsubishi
- MC TCP/IP protocol
- FX protocol
• Modicon
- Modbus TCP/IP protocol
- Modbus RTU protocol
•Omron
- Link/Multi-Link protocol
The following table contains more detailed information.
System interface possible
System interface not possible
1) Mobile Panel connection via special connecting cable and junction box
(see Mobile Panel), see Manual for cable layout.
2) The following listed controllers can be combined as required
3) Only Basic Panel PN, TP 177B DP/PN, OP 177B DP/PN,
Mobile Panel 177 PN
4) For Basic Panel, Touch Panel, Operator Panel, Comfort Panel, Multi Panel,
the RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is required
5) Not Basic Panel PN, Mobile Panel 177 PN
6) Connection via Allen Bradley PC cable 1747 CP3
7) Connection via Allen Bradley PC cable 1784 CP10
8) For connection to KF2/KF3 gateway, a gender-changer
(25-pin socket/25-pin socket) is required on the gateway side
Note:
For detailed information on cable assignment, refer to Online
Help of WinCC; see also FAQs:
http://support.automation.siemens.com/WW/view/en/29034071
Controller SIMATIC HMI
Target hardware (PROTOCOL)
(physics) OP 77A
TP 177A Basic Panel Comfort Panel OP 77B
TP 177B DP
OP 177B DP
TP 177B DP/PN
OP 177B DP/PN
Mobile Panel 177 DP1)
Mobile Panel 177 PN 1)
TP 277
OP 277
Mobile Panel 277 1)
MP 177
MP 277
MP 377
WinCC Runtime
Advanced
Allen Bradley (Ethernet IP)
via Ethernet TCP/IP network
to max. 4 x controllers 2)
ControlLogix 1756-L6x, -L6xS
with Ethernet module
1756-ENBT
Guard Logix System
CompactLogix 1769-L2xE,
-L3xE
CompactLogix 1769-L4x with
ETHERNET module
1768-ENBT
SLC 5/05
MicroLogix 1100, 1400
3) 3) • •
Allen Bradley (DF1)
to max. 1 x controller
SLC 5/03, /04, /05
MicroLogix (RS 232)
4) 4) 5) 4) 4) 5) 4) 6)
to max. 1 x controller
PLC5/11, /20, /30, /40, /60, /80
(RS 232)
4) 4) 5) 4) 4) 5) 4) 7)
via KF2 gateway and DH+ net-
work to max. 4 x controllers 2)
SLC 5/04
PLC5/11, /20, /30, /40, /60, /80
(RS 232)
4) 4) 5) 4) 4) 5) 4) 7) 8)
via KF2 gateway and DH+ net-
work to max. 4 x controllers 2)
SLC 5/04
PLC5/11, /20, /30, /40, /60, /80
(RS 422)
5) 5) • –
via KF3 gateway and DH485
network to max.
4 x controllers 2)
SLC 500
MicroLogix (RS 232)
4) 4) 5) 4) 4) 5) 4) 7) 8)
ST80_2013_EN_Kap02.book Seite 79 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
System interfaces with WinCC (TIA Portal)
Controllers from other manufacturers
2/80 Siemens ST 80 / ST PC · 2013
Overview (continued)
2
System interface possible
– System interface not possible
1) Mobile Panel connection via special connecting cable and junction box
(see Mobile Panel), see Manual for cable layout.
2) The following listed controllers can be combined as required
3) Only Basic Panel PN, TP 177B DP/PN, OP 177B DP/PN,
Mobile Panel 177 PN
4) Not Basic Panel PN, Mobile Panel 177 PN
5) Connection using a Mitsubishi PC cable SC-09 with integrated level
converter RS 232/RS 422
Note:
For detailed information on cable assignment, refer to Online
Help of WinCC; see also FAQs:
http://support.automation.siemens.com/WW/view/en/29034071
Controller SIMATIC HMI
Target hardware (PROTOCOL)
(physics) OP 77A
TP 177A Basic Panel Comfort Panel OP 77B
TP 177B DP
OP 177B DP
TP 177B DP/PN
OP 177B DP/PN
Mobile Panel 177 DP1)
Mobile Panel 177 PN 1)
TP 277
OP 277
Mobile Panel 277 1)
MP 177
MP 277
MP 377
WinCC Runtime
Advanced
Mitsubishi (MC TCP/IP)
via Ethernet IP network
to max. 4 x controllers 2)
FX series FX3G, FX3U, FX3UC
with Ethernet module FX3U
ENET,
Series Q with Ethernet module
QJ71E71-100
iQ series/QnUD QnUDEH
3) 3) • •
Mitsubishi FX (serial)
to max. 1 x controller
FX series FX1N, FX2N (RS 232) 4) 4) 5)
ST80_2013_EN_Kap02.book Seite 80 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
System interfaces with WinCC (TIA Portal)
Controllers from other manufacturers
2/81
Siemens ST 80 / ST PC · 2013
Overview (continued)
2
System interface possible
System interface not possible
1) Mobile Panel connection via special connecting cable and junction box
(see Mobile Panel), see Manual for cable layout.
2) The following listed controllers can be combined as required
3) Only Basic Panel PN, TP 177B DP/PN, OP 177B DP/PN,
Mobile Panel 177 PN
4) For Basic Panel, Touch Panel, Operator Panel, Comfort Panel, Multi Panel,
the RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is required
5) Not Basic Panel PN, Mobile Panel 177 PN
Note:
For detailed information on cable assignment, refer to Online
Help of WinCC; see also FAQs:
http://support.automation.siemens.com/WW/view/en/29034071
Controller SIMATIC HMI
Target hardware (PROTOCOL)
(physics) OP 77A
TP 177A Basic Panel Comfort Panel OP 77B
TP 177B DP
OP 177B DP
TP 177B DP/PN
OP 177B DP/PN
Mobile Panel 177 DP1)
Mobile Panel 177 PN 1)
TP 277
OP 277
Mobile Panel 277 1)
MP 177
MP 277
MP 377
WinCC Runtime
Advanced
Modicon (MODBUS TCP/IP)
Via MODBUS TCP/IP network to
max. 4 x controllers 2)
Concept Quantum,
Unity Quantum
• Momentum
Premium (TSX57)
TSX Micro (TSX37)
Modicon M340 20x0
(except 2010)
3) 3) • •
Via TCP/IP Modbus Plus
Bridge 174 CEV 200 40 and
MODBUS PLUS network to
max. 4 x controllers 2)
Concept Quantum,
Unity Quantum
• Momentum
• Compact
3) 3) • •
Modicon (MODBUS RTU)
to max. 1 x controller
Concept Quantum
• Momentum
• Compact
(RS 232)
4) 4) 5) 4) 4) 5) 4)
Via bridge BM85-000 or PLC
with bridge functionality and
MODBUS PLUS network to
max. 4 x controllers 2)
Concept Quantum
Compact (RS 232)
4) 4) 5) 4) 4) 5) 4)
ST80_2013_EN_Kap02.book Seite 81 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
System interfaces with WinCC (TIA Portal)
Controllers from other manufacturers
2/82 Siemens ST 80 / ST PC · 2013
Overview (continued)
2
• System interface possible
System interface not possible
1) Mobile Panel connection via special connecting cable and junction box
(see Mobile Panel), see Manual for cable layout.
2) The controllers listed below can be combined in any way required;
connection via RS 422 interface of the controller or via RS 422 module
3) For Basic Panel, Touch Panel, Operator Panel, Comfort Panel, Multi Panel,
the RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is required
4) Not Basic Panel PN, Mobile Panel 177 PN
Note:
For detailed information on cable assignment, refer to Online
Help of WinCC; see also FAQs:
http://support.automation.siemens.com/WW/view/en/29034071
Controller SIMATIC HMI
Target hardware (PROTOCOL)
(physics) OP 77A
TP 177A Basic Panel Comfort Panel OP 77B
TP 177B DP
OP 177B DP
TP 177B DP/PN
OP 177B DP/PN
Mobile Panel 177 DP1)
Mobile Panel 177 PN 1)
TP 277
OP 277
Mobile Panel 277 1)
MP 177
MP 277
MP 377
WinCC Runtime
Advanced
Omron (Link/MultiLink)
to max. 1 x controller
CP1L, CP1H, CP1E
CJ1M, CJ1H, CJ1G
•CJ2H
CS1G, CS1H, CS1D
CP2MC (RS 232)
––3) 3) 4) 3)
via converter NT-AL001 and
RS 422 network to
max.4 x controllers 2)
CP1L, CP1H, CP1E
CJ1M, CJ1H, CJ1G
•CJ2H
CS1G, CS1H, CS1D
CP2MC (RS 232)
––3) 3) 4) 3)
via RS 422 network to
max. 4 x controllers 2)
CP1L, CP1H, CP1E
CJ1M, CJ1H, CJ1G
(RS 422)
4) 4) 4)
via RS422 network to
max. 4 x controllers 2)
•CJ2H
CS1G, CS1H, CS1D
CP2MC (RS 422)
4) 4)
ST80_2013_EN_Kap02.book Seite 82 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
System interfaces with WinCC flexible
System interfaces with WinCC flexible
2/83
Siemens ST 80 / ST PC · 2013
2
Overview
SIMATIC Basic Panel, Touch Panels (TP), Operator Panels (OP),
Mobile Panel, Multifunctional Platforms (MP)1) and the SIMATIC
HMI software package for PC WinCC flexible Runtime support
HMI functionality in conjunction with:
SIMATIC S7
SIMATIC S5
SIMATIC 505
SIMOTION
SINUMERIK 2)
Non-Siemens controllers:
- Allen Bradley - DF1, DH485 and Ethernet IP protocols
- GE Fanuc - SNP/SNPX protocol
- LG GLOFA GM - dedicated protocol
- Mitsubishi - FX and MP 4 protocols
- Modicon - Modbus RTU and TCP/IP protocols
- Omron I - Link/MultiLink protocol
- Telemecanique - UNI-TELWAY protocol
For more detailed information, refer to the WinCC flexible user
manual, the "Windows-based systems communication" manual,
and the WinCC flexible online help.
1) For the sake of simplicity, SIMATIC TP/OP/MP is always used in the text
below. This is not restrictive, as the information is valid for all systems
referred to above. If there are constraints, direct reference is made to them
in the text.
2) Required under WinCC flexible: "SINUMERIK HMI copy license
WinCC flexible CE" and "SINUMERIK HMI copy license OA".
For configuring, a "SINUMERIK HMI engineering package WinCC flexible"
is also necessary.
Note
Interface options for HMI devices: See the individual device
descriptions.
Extended functionality with WinCC flexible
WinCC flexible supports OPC communication for Multi Panel
and WinCC flexible Runtime and HTTP communication for all
panels with integrated Ethernet interface. Both OPC and HTTP
communication can be used in parallel with the process links to
SIMATIC S7/S5/505 or non-Siemens PLCs.
OPC Data Access
(MP 277, MP 377, WinCC flexible Runtime only)
OPC Data Access is an open standard for exchanging both local
and remote variables between various applications via Industrial
Ethernet. The original version of OPC is based on Microsoft
COM/DCOM and, therefore, requires a Microsoft Windows-
based PC operating system (not Windows CE) on both clients
and servers. As OPC XML, communication is based on the
Internet standard SOAP/XML and is, therefore, suitable for
embedded systems with Windows CE.
Options that are required: WinCC flexible/OPC server
HTTP communication for the variable exchange between
SIMATIC HMI systems
(only TP 177B DP/PN, OP 177B DP/PN, Mobile Panel 177 PN,
TP 277, OP 277, Mobile Panel 277, Mobile Panel 277 IWLAN,
MP 277, MP 377, WinCC flexible Runtime)
Communication based on HTTP message frames enables
variables to be exchanged between SIMATIC HMI systems.
Options that are required: WinCC flexible/Sm@rt Access
System interface possible
System interface not possible
1) Option WinCC flexible/OPC Server for WinCC flexible Runtime required
2) Only with DCOM/XML gateway included in the scope of delivery of
WinCC flexible for access to MP 277, MP 377 and MP 370 OPC XML
servers
3) Option WinCC flexible/OPC Server for SIMATIC Multi Panel required
4) Option WinCC flexible/Sm@rtAccess for SIMATIC Panel required
5) Option WinCC flexible/Sm@rtAccess for WinCC flexible Runtime required
6) Depending on the terminal box used
Communication standard SIMATIC HMI
Version TP 177B DP/PN
OP 177B DP/PN
Mobile Panel 177 PN
MP 177
TP 277
OP 277
Mobile Panel 277 6)
Mobile Panel 277
IWLAN
MP 277
MP 377
WinCC flexible
Runtime Connection via
OPC Data Access V2.05a + OPC Data Access XML V1.00
OPC client
(COM/DCOM) Industrial Ethernet
(see Catalog IK PI)
OPC server
(COM/DCOM) – •1) Industrial Ethernet
(see Catalog IK PI)
OPC XML client
(SOAP/XML) – •2) Industrial Ethernet
(see Catalog IK PI)
OPC XML server
(SOAP/XML) – •3) Industrial Ethernet
(see Catalog IK PI)
HTTP communication for variable exchange between SIMATIC HMI systems
HTTP client 4) 4) 4) 5) Industrial Ethernet
(see Catalog IK PI)
HTTP server 4) 4) 4) 5) Industrial Ethernet
(see Catalog IK PI)
ST80_2013_EN_Kap02.book Seite 83 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
System interfaces with WinCC flexible
SIMATIC S7
2/84 Siemens ST 80 / ST PC · 2013
2
Overview
The following types of interface are supported in respect of the
link between SIMATIC HMI Panels and SIMATIC WinCC flexible
Runtime with SIMATIC S7:
PPI interface:
Interface between SIMATIC HMI Panels and SIMATIC S7-200
via PPI. Communication runs on the PPI protocol, a standard
FB as with SIMATIC S5 is not required.
MPI interface:
Interface between SIMATIC HMI Panels and SIMATIC S7 via
the integrated PPI interface with S7-200 or MPI interface with
S7-300/-400 or alternatively via the MPI interface of a separate
interface module and the backplane bus to the SIMATIC S7-
CPU. Communication runs on the MPI protocol (PG/OP
communication), a standard FB as with SIMATIC S5 is not
required.
PROFIBUS interface:
Interface between SIMATIC HMI Panels and SIMATIC S7 via
the integrated PROFIBUS interface on the CPU or alternatively
via the PROFIBUS interface on a separate interface module
and the backplane bus to the SIMATIC S7-CPU. Communi-
cation runs on the MPI protocol (PG/OP communication), a
standard FB as with SIMATIC S5 is not required.
PROFINET interface:
Interface between SIMATIC HMI Panels and SIMATIC S7 via
the integrated PROFINET interface on the CPU or alternatively
via the Industrial Ethernet interface on a separate interface
module and the backplane bus to the SIMATIC S7-CPU.
Communication runs on the MPI protocol (PG/OP communi-
cation), a standard FB as with SIMATIC S5 is not required.
The maximum possible number of S7 connections of a CPU is
determined by its power (see Catalog ST 70); from the point of
view of SIMATIC HMI Panels the following restrictions apply:
OP 73micro, TP 177micro: 1 connection
OP 73: max. 2 connections
OP 77A, TP 177A, Basic Panel, OP 77B, TP177B, OP 177B,
Mobile Panel 177: max. 4 connections
TP 277, OP 277; Mobile Panel 277, MP 177, MP 277, MP 377:
max. 6 connections
PC with WinCC flexible Runtime: max. 8 connections
PPI interface
From the point of view of the concept, the PPI interface is a point-
to-point connection between a SIMATIC HMI Panel (PPI master)
or alternatively a PG (PPI master), and an S7-200 (PPI slave).
MPI interface/PROFIBUS interface/
Industrial Ethernet interface
The multipoint-enabled communication interfaces of
SIMATIC HMI Panels and SIMATIC S7 are used.
Options are:
Interface between one or a number of SIMATIC HMI Panels
(MPI master) and one or a number of S7-300/400s or WinAC
(MPI master)
(possible network topology: "MPI/PROFIBUS/Industrial
Ethernet")
Interface between one or a number of SIMATIC HMI Panels
(MPI master) and one or a number of S7-200s (MPI slave) 1)
(possible network topology: "PPI/MPI/PROFIBUS")
Unlike PPI connections, MPI connections are static connections
that are set up during booting and then monitored.
The original format of a master/master link has in the meantime
been joined by a master/slave link, which has enabled
integration of the S7-200 (except CPU 212). 1)
In principle this type of information exchange between
SIMATIC HMI Panels and SIMATIC S7 is independent of the
network used, PPI, MPI, PROFIBUS or Industrial Ethernet:
SIMATIC HMI Panels are S7 clients and SIMATIC S7 CPUs are
S7 servers.
1) Constraints with regard to baud rate for S7-200; see Catalog ST 70.
ST80_2013_EN_Kap02.book Seite 84 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
System interfaces with WinCC flexible
SIMATIC S7
2/85
Siemens ST 80 / ST PC · 2013
Overview (continued)
2
System interface possible
System interface not possible
1) TD series can only be interfaced with max. 1 x S7-200 via PPI (PPI/MPI);
network operation (parallel PG, etc.) possible; max. data transfer rate
187.5 kbit/s; cable included in scope of supply
2) OP 73micro, TP 177 micro can only be interfaced with max. 1 x S7-200
(MPI); network operation (parallel PG, etc.) possible; max. data transfer
rate 187.5 kbit/s
3) OP 73 can only be interfaced with max. 2 x SIMATIC S7 (MPI); network
operation (parallel PG, etc.) possible; max. data transfer rate 1.5 Mbit/s
4) Max. transmission rate 1.5 Mbit/s
5) MPI cable 6ES7 901-0BF00-0AA0 (max. 187.5 Kbit/s) included in PG
scope of delivery
6) Bus connector 6GK1 500-0EA02
Controller SIMATIC HMI
Target hardware (PROTOCOL)
(physics) TD 100C
TD 200
TD 200C
TD 400C
OP 73micro
TP 177micro
OP 73 OP 77A
TP 177A
Connection via
SIMATIC S7 (PPI/MPI)
via PPI on S7-200 (PPI) 1) MPI cable 5)
via MPI or PROFIBUS
(PG/OP communication)
with S7-200
2) 3) 4) MPI cable 5)
via MPI or PROFIBUS
(PG/OP communication)
with S7-300, -400
3) 4) MPI cable 5)
via PPI network (PPI)
with max. 1 x S7-200 1) PPI network 6)
(see Catalog ST 70 and IK PI)
via PPI network
(PG/OP communication)
with max. 4 x S7-200
1) 2) 3) 4) PPI network 6)
(see Catalog ST 70 and IK PI)
via MPI or PROFIBUS network
(PG/OP communication)
with max. 4 x S7-200
2) 3) 4) MPI or PROFIBUS network 6)
(see Catalogs ST 70 and IK PI)
via MPI or PROFIBUS network
(PG/OP communication)
with max. 4 x S7-300, -400, WinAC
3) 4) MPI or PROFIBUS network 6)
(see Catalogs ST 70 and IK PI)
via Industrial Ethernet (TCP/IP)
(PG/OP communication)
with max. 4 x S7-200, -300, -400,
WinAC
Industrial Ethernet
(see Catalog IK PI)
ST80_2013_EN_Kap02.book Seite 85 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
System interfaces with WinCC flexible
SIMATIC S7
2/86 Siemens ST 80 / ST PC · 2013
Overview (continued)
2
System interface possible
– System interface not possible
1) Can only be interfaced with max. 1 x S7-200 via PPI (PPI);
network operation (parallel PG, etc.) possible
2) Not Basic Panel PN, Mobile Panel 177 PN, Mobile Panel 277 IWLAN;
Mobile Panel 177 DP, Mobile Panel 277 connection via special
connecting cable and junction box (see Mobile Panel);
Please refer to the manual for cable assignment
3) Connection via integrated MPI/PROFIBUS interface; use the CP 5611 A2
with a standard PC.
4) Max. transmission rate 1.5 Mbit/s
5) Only on passive S7-200; OP 77B (MPI) also on active S7-200
6) Only OP 77B (MPI)
7) Only Basic Panel PN, TP 177B DP/PN, OP 177B DP/PN,
Mobile Panel 177 PN
8) Mobile Panel 177 PN, Mobile Panel 277 connection via special connecting
cable and junction box (see Mobile Panel);
Please refer to the manual for cable assignment
9) Mobile Panel 277 IWLAN (wireless interface, see Mobile Panel)
10)Connection via integrated Industrial Ethernet interface; use the CP 1612
with a standard PC
11)MPI cable 6ES7 901-0BF00-0AA0 (max. 187.5 Kbit/s) included in PG
scope of delivery (for download and test purposes only)
12)Bus connector 6GK1 500-0EA02
Controller SIMATIC HMI
Target hardware (PROTOCOL)
(physics) Basic Panels OP 77B
TP 177B DP
OP 177B DP
TP 177B DP/PN
OP 177B DP/PN
Mobile Panel 177 DP
Mobile Panel 177 PN
TP 277
OP 277
Mobile Panel 277
Mobile Panel 277
IWLAN
MP 177
MP 277
MP 377
WinCC flexible
Runtime Connection via
via PPI on S7-200 (PPI) 1) 2) 1) 2) 1) 3) MPI cable 11)
via MPI or PROFIBUS
(PG/OP communication)
on S7-200
2) 2)5) 2) 5) 3) 5) MPI cable 11)
via MPI or PROFIBUS
(PG/OP communication)
with S7-300, -400
2) 2) 2) 3) MPI cable 11)
via PPI network (PPI)
with max. 1 x S7-200 1) 2) 1) 2) 1) 3) PPI network 12)
(see Catalog ST 70
and IK PI)
via PPI network
(PG/OP communication)
with max. 4 x S7-200
2) 6) PPI network 12)
(see Catalog ST 70
and IK PI)
via MPI or PROFIBUS network
(PG/OP communication)
with max. 4 x S7-200
2) 2) 5) 2) 5) 3) 5) MPI or PROFIBUS
network 12)
(see Catalogs ST 70
and IK PI)
via MPI or PROFIBUS network
(PG/OP communication)
with max. 4 x S7-300, -400, WinAC
2) 2) 2) 3) MPI or PROFIBUS
network 12)
(see Catalogs ST 70
and IK PI)
via Industrial Ethernet (TCP/IP)
(PG/OP communication)
with max. 4 x S7-200, -300, -400,
WinAC
7) 7) 8) 8) 9) 10) Industrial Ethernet
(see Catalog IK PI)
ST80_2013_EN_Kap02.book Seite 86 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
System interfaces with WinCC flexible
SIMATIC S5
2/87
Siemens ST 80 / ST PC · 2013
2
Overview
A variety of interfaces differing in respect of type and
performance are available for linking SIMATIC HMI Panels to
SIMATIC S5 (not S5-150U). However, a feature common to all is
that from the point of view of the connected SIMATIC HMI Panel,
the connection is always a logical point-to-point one, i.e. there is
always a fixed assignment between a SIMATIC HMI Panel and a
PLC.
AS511 interface
(not for OP 77A, TP 177A, Basic Panel, Mobile Panel 177,
Mobile Panel 277)
S5-90U to -135U, -155U
(except CPU 922 < Version 9,
except CPU 928 [6ES5 928-3UA11],
except CPU 946/947 [6ES5 94•-3UA11],
except CPU 946/947 [6ES5 94•-3UA21],
except CPU 946/947 [6ES5 94•-3UA22] < Version 5)
The AS511 interface is implemented via the PG interface of
SIMATIC S5 and uses the associated CPU resources, that is, the
performance capability of the SIMATIC HMI Panel is determined
by the performance capability of the SIMATIC CPU used.
PROFIBUS DP interface
(not for OP 77A, TP 177A, Basic Panel, Mobile Panel 177 PN,
Mobile Panel 277 IWLAN)
S5-115U, -135U, -155U via IM 308C or
CP 5431 FMS/ DP (except CPU 922 < Version 9,
except CPU 928 [6ES5 928-3UA11],
except CPU 946/947 [6ES5 94•-3UA11],
except CPU 946/947 [6ES5 94•-3UA21],
except CPU 946/947 [6ES5 94•-3UA22] < Version 5)
The PROFIBUS DP interface supports the connection of:
Up to 2 SIMATIC HMI Panels as SLAVES via a PROFIBUS
network to a SIMATIC S5-95U with integrated PROFIBUS DP/
master interface [6ES5 095-8ME01]
Up to 30 SIMATIC HMI Panels as SLAVES via a PROFIBUS
network to a SIMATIC S5 with separate PROFIBUS DP/master
interface IM 308C, or CP 5431 FMS/DP
Communication between SIMATIC HMI Panels (DP slaves)
and SIMATIC S5 (DP master) runs via PROFIBUS DP message
frames in accordance with EN 50170 with higher-level
"HMI profile". A function block which must be called for each
connected SIMATIC HMI Panel is required in the PLC
(FB is included in scope of delivery).
ST80_2013_EN_Kap02.book Seite 87 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
System interfaces with WinCC flexible
SIMATIC S5
2/88 Siemens ST 80 / ST PC · 2013
Overview (continued)
2
System interface possible
System interface not possible
1) PC cable with integrated level converter RS 232/TTY
2) OP 77B only
3) WinCC flexible 2008 Service Pack 2 and higher
4) Connection via integrated MPI/PROFIBUS interface: use the CP 5611 A2
for a standard PC.
5) not for OP 77B; in this case the RS 232 interface is to be used.
Controller SIMATIC HMI
Target hardware (PROTOCOL)
(physics)
OP 77A
TP 177A
Basic Panel
OP 77B
TP 177B DP
OP 177B DP
TP 177B DP/PN
OP 177B DP/PN
Mobile Panel 177 DP
Mobile Panel 177 PN
TP 277
OP 277
Mobile Panel 277
Mobile Panel 277 IWLAN
MP 177
MP 277
MP 377
WinCC flexible
Runtime Connection via
SIMATIC S5 (AS511)
S5-90U to 155U
except CPU 922 < version 9,
except CPU 928
(6ES5 928-3UA11)
except CPU 946/947
(6ES5 94.-3UA11,
6ES5 94.-3UA21,
6ES5 94.-3UA22 < version 5)
(TTY)
2) 6ES5 734-1BD201)
(3.2 m)
6XV1 440-2A
(see HMI accessories/
connecting cables)
S5-90U to 155U
except CPU 922 < version 9,
except CPU 928
(6ES5 928-3UA11)
except CPU 946/947
(6ES5 94.-3UA11,
6ES5 94.-3UA21,
6ES5 94.-3UA22 < version 5)
(TTY)
3) 5) 3) 6AV6 671-8XJ00-
0AX0
(RS422-TTY adapter)
6XV1 440-2A
(see HMI accessories/
connecting cables)
SIMATIC S5 (PROFIBUS DP + HMI)
via PROFIBUS DP with
1 x S5-95U/L2-DP/master
(6ES5 095-8ME02)
– •3) 3) 4) PROFIBUS4)
(see Catalog IK PI)
via PROFIBUS DP with IM 308C
on S5-115U, -135U, -155U
except CPU 922 < version 9,
except CPU 928
(6ES5 928-3UA11),
except CPU 946/947
(6ES5 94.-3UA11,
6ES5 94.-3UA21,
6ES5 94.-3UA22 < version 5)
– •3) 3) 4) PROFIBUS4)
(see Catalog IK PI)
via PROFIBUS DP with
CP 5431 FMS/DP on
S5-115U, -135U, -155U
except CPU 922 < version 9,
except CPU 928
(6ES5 928-3UA11),
except CPU 946/947
(6ES5 94.-3UA11,
6ES5 94.-3UA21,
6ES5 94.-3UA22 < version 5)
– •3) 3) 4) PROFIBUS4)
(see Catalog IK PI)
ST80_2013_EN_Kap02.book Seite 88 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
System interfaces with WinCC flexible
SIMATIC 505
2/89
Siemens ST 80 / ST PC · 2013
2
Overview
A variety of interfaces differing in respect of type and perfor-
mance are available for linking SIMATIC HMI Panels to
SIMATIC 505.
However, a feature common to all is that from the point of view of
the connected SIMATIC HMI Panel, the connection is always a
logical point-to-point one, that is, there is always a fixed
assignment between an HMI Panel and a PLC.
NITP interface
(not for OP 77A, TP 177A, Basic Panel, Mobile Panel 177 PN,
Mobile Panel 277 IWLAN)
The NITP interface runs via the PG interface of the SIMATIC 505
and uses the associated CPU resources, that is, the perfor-
mance capability of the SIMATIC HMI Panel is determined by the
performance capability of the SIMATIC CPU used.
PROFIBUS DP interface
(not for OP 77A, TP 177A, Basic Panel, Mobile Panel 177 PN,
Mobile Panel 277 IWLAN)
SIMATIC 505 PLC or SIMATIC 545, SIMATIC 555 with CP 5434
With the PROFIBUS DP interface, up to 30 SIMATIC HMI Panels
can be connected as SLAVES to one SIMATIC 545, 555 via a
PROFIBUS network, with plug-in PROFIBUS DP/master interface
type CP 5434.
Communication between SIMATIC HMI Panels (DP slaves) and
SIMATIC 505 (DP master) runs via PROFIBUS DP message
frames in accordance with EN 50170 with higher-level "HMI
profile". An application ladder which must be called for each
connected SIMATIC HMI Panel is required in the PLC (example
of application ladder included in ProTool scope of delivery).
System interface possible
– System interface not possible
1) Not Mobile Panel 177 PN, Mobile Panel 277 IWLAN Mobile Panel 177 DP,
Mobile Panel 277 connection via special connecting cable and
junction box (see Mobile Panel); see manual for cable assignment.
2) The RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is required for Touch
Panels, Operator Panels, and Multi Panels
3) A standard adapter (9-/25-pin male) is required on the PLC
4) A commercially available level converter (RS 232/RS 422) is required on
the PC
5) Connection via integrated MPI/PROFIBUS interface, use the CP 5611 A2
with a standard PC
6) Detailed information (cable assignment) can be found in the online help for
WinCC flexible and in the Communication User Manual for Windows-based
systems
7) Bus connector 6GK1 500-0EA02
Controller SIMATIC HMI
Target hardware (PROTOCOL)
(physics) OP 77A
TP 177A
Basic Panel
OP 77B
TP 177B DP
OP 177B DP
TP 177B DP/PN
OP 177B DP/PN
Mobile Panel 177 DP
Mobile Panel 177 PN
TP 277
OP 277
Mobile Panel 277
Mobile Panel 277 IWLAN
MP 177
MP 277
MP 377
WinCC flexible
Runtime Connection via
SIMATIC 505 (NITP)
PLC 525, 535, 565T
(RS 232) 1) 2) 1) 2) PPX: 2601 094-8001 3)
See online help 6)
PLC 545, 555
(RS 232) 1) 2) 1) 2) PPX: 2601 094-8001 3)
6XV1 440-2K…
(see HMI accessories/
connecting cables)
PLC 535, 545/CPU 1101, 565T
(RS 422) 1) 1) 4) See online help 6)
PLC 545/CPU 1102, 555
(RS 422) 1) 1) 4) See online help 6)
SIMATIC 505 (PROFIBUS DP + HMI)
via PROFIBUS DP to
1 x PLC 545, 555 with CP 5434 1) 1) 5) PROFIBUS 7)
(see Catalog IK PI)
ST80_2013_EN_Kap02.book Seite 89 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
System interfaces with WinCC flexible
PLCs from other manufacturers
2/90 Siemens ST 80 / ST PC · 2013
2
Overview
Allen Bradley
Three communication protocols are available for the interface
between SIMATIC TP/OP/MP and Allen Bradley:
DF1 interface
(not on OP 73, Basic Panel PN, Mobile Panel 177 PN,
Mobile Panel 277 IWLAN)
This communication between SIMATIC TP/OP/MP and Allen
Bradley runs on the basis of the DF1 protocol; the following have
been tested and released:
Direct connection between a SIMATIC TP/OP/MP and the PG
interface on an Allen Bradley PLC5 or the DF1 interface on an
Allen Bradley SLC500 (point-to-point link)
The integration of SIMATIC TP/OP/MP via Allen Bradley KF2
gateway in an Allen Bradley DH+ network. Communication is
possible between SIMATIC TP/OP/MP and up to 4 SLC 500
PLCs or PLC5s (multipoint link from the point of view of the
SIMATIC TP/OP/MP; only one connection possible with TP
170A)
The integration of SIMATIC TP/OP/MP via Allen Bradley KF3
gateway in an Allen Bradley DH485 network. Communication
is possible between SIMATIC TP/OP/MP and up to 4 PLCs
type SLC 500 or MicroLogix (multipoint link from the point of
view of the SIMATIC TP/OP/MP; only one connection possible
with TP 170A)
DH485 interface
(not on OP 73, OP 77A, TP 177A, Basic Panel,
Mobile Panel 177 PN, Mobile Panel 277 IWLAN)
This communication between SIMATIC TP/OP/MP and Allen
Bradley runs on the basis of the DH485 protocol; the following
have been tested and released:
Direct connection between a SIMATIC TP/OP/MP and an Allen
Bradley SLC500 or MicroLogix (point-to-point link)
The integration of SIMATIC TP/OP/MP via Allen Bradley AIC
adapter in an Allen Bradley DH485 network. Communication
is possible between SIMATIC TP/OP/MP and up to 4 PLCs
type SLC 500 or MicroLogix (multipoint link from the point of
view of the SIMATIC TP/OP/MP; only one connection possible
with TP 170A)
The integration of SIMATIC TP/OP/MP (not PC with
WinCC flexible Runtime) in an Allen Bradley DH485 network.
Communication is possible between SIMATIC TP/OP/MP and
up to 4 PLCs type SLC 500 or MicroLogix (multipoint link from
the point of view of the SIMATIC TP/OP/MP; only one
connection possible with TP 170A)
Ethernet IP protocol
(not on OP 73, OP 77A, TP 177A, Basic Panel, OP 77B,
TP 177B DP, OP 177B DP, Mobile Panel 177 DP,
Mobile Panel 277 IWLAN)
This communication between SIMATIC TP/OP/MP and
Allen Bradley runs based on the Ethernet IP protocol;
SIMATIC TP/OP/MP integration is tested and released in an
Ethernet IP network. Communication is possible between
SIMATIC TP/OP/MP and up to 4 ControlLogix or
CompactLogix PLCs (multipoint link from the point of view
of the SIMATIC TP/OP/MP)
GE-Fanuc
(not on OP 73, OP 77A, TP 177A, Basic Panel,
Mobile Panel 177 PN, Mobile Panel 277 IWLAN)
Communication between SIMATIC TP/OP/MP and GE-Fanuc
runs on the basis of the SNP protocol; the following have been
tested and released:
Direct connection between a SIMATIC TP/OP/MP and
a GEF 90-Micro, 90-30 or 90-70 (point-to-point link)
Integration of SIMATIC TP/OP/MP in an RS 422 network
via adapter. Communication is possible between
SIMATIC TP/OP/MP and up to 4 GEF 90-Micro, 90-30 or
90-70 PLCs (multipoint link from the point of view of the
SIMATIC TP/OP/MP; only one connection possible with
TP 170A)
The integration of SIMATIC TP/OP/MP (not PC with ProTool/
Pro Runtime or WinCC flexible Runtime) in an RS 422 network.
Communication is possible between SIMATIC TP/OP/MP and
up to 4 GEF 90-Micro, 90-30 or 90-70 PLCs (multipoint link
from the point of view of the SIMATIC TP/OP/MP; only one
connection possible with TP 170A)
LG GLOFA GM
(not on OP 73, OP 77A, TP 177A, Basic Panel,
Mobile Panel 177 PN, Mobile Panel 277 IWLAN)
Communication between SIMATIC TP/OP/MP and
LG GLOFA GM runs on the basis of the dedicated protocol;
the following have been tested and released:
Connection between a SIMATIC TP/OP/MP and an
LG GLOFA GM with Cnet module (point-to-point link)
Integration of SIMATIC TP/OP/MP in an RS 422 network via
LG Cnet module. Communication is possible between
SIMATIC TP/OP/MP (not PC with ProTool/Pro Runtime) and up
to 4 LG GLOFA GM PLCs on the network (multipoint link from
the point of view of the SIMATIC TP/OP/MP; only one
connection possible with TP 170A)
Mitsubishi
(not with OP 73, Basic Panel, Mobile Panel 177 PN,
Mobile Panel 277 IWLAN)
Two communication protocols are available for the interface
between SIMATIC TP/OP/MP and Mitsubishi:
FX protocol
This communication between SIMATIC TP/OP/MP and
Mitsubishi runs on the basis of the FX protocol; the direct
connection between a SIMATIC TP/OP/MP and the PG interface
of a Mitsubishi FX/FX0 (logical point-to-point link) has been
tested and released.
MP4 protocol
This communication between SIMATIC TP/OP/MP and
Mitsubishi runs on the basis of the MP4 protocol;
the following have been tested and released:
Direct connection between a SIMATIC TP/OP/MP and a
Mitsubishi Series FX, Series A or Series Q (point-to-point link)
Integration of SIMATIC TP/OP/MP in an RS 422 network via
Mitsubishi converter FX-48SC-IF. Communication is possible
between SIMATIC TP/OP/MP and up to 4 Series FX, Series A
or Series Q PLCs (multipoint link from the point of view of the
SIMATIC TP/OP/MP; only one connection possible with
TP 170A)
The integration of SIMATIC TP/OP/MP (not PC with ProTool/
Pro Runtime or WinCC flexible Runtime) in an RS 422 network.
Communication is possible between SIMATIC TP/OP/MP and
up to 4 Series FX, Series A or Series Q PLCs (multipoint link
from the point of view of the SIMATIC TP/OP/MP; only one
connection possible with TP 170A)
ST80_2013_EN_Kap02.book Seite 90 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
System interfaces with WinCC flexible
PLCs from other manufacturers
2/91
Siemens ST 80 / ST PC · 2013
Overview (continued)
2
Modicon
Two communication protocols are available for the interface
between SIMATIC TP/OP/MP and Modicon:
Modbus protocol
(not for OP 73, Basic Panel PN, Mobile Panel 177 PN,
Mobile Panel 277 IWLAN)
Communication between SIMATIC TP/OP/MP and Modicon runs
on the basis of the Modbus protocol; the following have been
tested and released:
Direct connection between a SIMATIC TP/OP/MP and the
Modbus interface on a Modicon 984, TSX Quantum or
TSX Compact (point-to-point link)
The integration of a SIMATIC TP/OP/MP via Modicon
Modbus PLUS bridge BM85-000 or the bridge function of a
MODICON 984-145 or TSX Quantum into a Modbus PLUS
network and communication between SIMATIC TP/OP/MP
(Modbus/master) and up to 4 Modicon 984 or TSX Quantum
PLCs (Modbus/slave) on the network (multipoint link from the
point of view of the SIMATIC TP/OP/MP; only one connection
possible with TP 170A).
Modbus TCP/IP protocol
(not for OP 73, OP 77A, TP 177A, Basic Panel DP, OP77B,
TP 177B DP, OP 177B DP, Mobile Panel 177 DP,
Mobile Panel 277 IWLAN)
This communication between SIMATIC TP/OP/MP and Modicon
runs on the basis of the Modbus TCP/IP protocol; the following
have been tested and released:
Integration of SIMATIC TP/OP/MP into a Modbus TCP/IP
network. Communication is possible between
SIMATIC TP/OP/MP and up to 4 Momentum, TSX Micro
( TSX 37 ), TSX Premium ( TSX 57 ), TSX Unity Premium,
TSX Quantum or TSX Unity Quantum PLCs (multipoint link
from the point of view of the SIMATIC TP/OP/MP)
The communication between SIMATIC TP/OP/MP via
TCP/IP Modbus Plus Bridge 174 CEV 200 40 / Modbus PLUS
network to Modicon 984 (except 984A, 984B, 984X ),
TSX Compact, TSX Quantum or TSX Unity Quantum (multi-
point link from the point of view of the SIMATIC TP/OP/MP)
Omron
(not with OP 73, Basic Panel PN, Mobile Panel 177 PN,
Mobile Panel 277 IWLAN)
Communication between SIMATIC TP/OP/MP and Omron runs
on the basis of the Link/MultiLink protocol; the following have
been tested and released:
Direct connection between a SIMATIC TP/OP/MP and an
Omron Sysmac C, Sysmac or Sysmac CV (point-to-point
link)
Integration of SIMATIC TP/OP/MP in an RS 422 network
via Omron converter NT-AL001. Communication is possible
between SIMATIC TP/OP/MP and up to 4 Sysmac C,
Sysmac or Sysmac CV PLCs (multipoint link from the point
of view of the SIMATIC TP/OP/MP; only one connection
possible with TP 170A)
The integration of SIMATIC TP/OP/MP (not PC with ProTool/
Pro Runtime or WinCC flexible Runtime) in an RS 422 network.
Communication is possible between SIMATIC TP/OP/MP and
up to 4 Sysmac C, Sysmac or Sysmac CV PLCs (multipoint
link from the point of view of the SIMATIC TP/OP/MP; only one
connection possible with TP 170A)
Telemecanique
(not on OP 73, OP 77A, TP 177A, Basic Panel,
Mobile Panel 177 PN, Mobile Panel 277 IWLAN,
WinCC flexible Runtime)
Data exchange between SIMATIC TP/OP/MP and
Telemecanique runs on the basis of the UNI-TELWAY protocol;
the following have been tested and released:
Connection between a SIMATIC TP/OP/MP (UNI-T/slave) via
Telemecanique outlet TSX SCA62 and a Telemecanique
TSX 17 or TSX 47/67/87/107 (UNI-T/master)
(logical point-to-point link)
Connection between a SIMATIC TP/OP/MP (UNI-T/slave) via
Telemecanique outlets TSX SCA62 + ACC01 and a Telemeca-
nique TSX 37 or TSX 57 (UNI-T/master) (logical point-to-point
link)
The integration of a SIMATIC TP/OP/MP via Telemecanique
outlet TSX SCA62 in a UNI-TELWAY network and communi-
cation between SIMATIC TP/OP/MP (UNI-T/slave) and up to
4 TSX 17, TSX 37, TSX 57 or TSX 47/67/87/107 PLCs (UNI-T/
master or slave) on the network (multipoint link from the point
of view of the SIMATIC TP/OP/MP; only one connection
possible with TP 170A).
ST80_2013_EN_Kap02.book Seite 91 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
System interfaces with WinCC flexible
PLCs from other manufacturers
2/92 Siemens ST 80 / ST PC · 2013
Overview (continued)
2
System interface possible
– System interface not possible
1) Not Basic Panel PN, Mobile Panel 177 PN, Mobile Panel 277 IWLAN;
Mobile Panel 177 DP, Mobile Panel 277 connection via special connecting
cable and junction box (see Mobile Panel); see manual for cable
assignment.
2) The RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is required for
Basic Panel, Touch Panel, Operator Panel, and Multi Panel
3) Only TP 177B DP/PN, OP 177B DP/PN, Mobile Panel 177 PN
4) Mobile Panel 177 PN, Mobile Panel 277 connection via special connecting
cable and junction box (see Mobile Panel); see manual for cable
assignment.
5) Not Mobile Panel 277 IWLAN (wireless interface, see Mobile Panel)
6) Connection via integrated Industrial Ethernet interface; use the
CP 1612 with a standard PC
7) Allen Bradley PC cable
8) Cable for connection to KF2/KF3 gateway; a gander changer
(25-pin socket/25-pin socket) is required on the gateway side
9) Detailed information (cables used) see FAQ:
http://support.automation.siemens.com/WW/view/en/29034071
in the online help for WinCC flexible and in the Communication User
Manual for Windows-based systems
Controller SIMATIC HMI
Target hardware (PROTOCOL)
(physics) OP 77A
TP 177A
Basic Panel OP 77B
TP 177B DP
OP 177B DP
TP 177B DP/PN
OP 177B DP/PN
Mobile Panel
177 DP / 177 PN
TP 277
OP 277
Mobile Panel
277 / 277 IWLAN
MP 177
MP 277
MP 377
WinCC flexible
Runtime Connection via
Allen Bradley (DF1)
SLC 500/03,04,05 or MicroLogix
(RS 232) 1) 2) 1) 2) 1) 2) 1) 2) 1747 CP3 7)
See FAQ 9)
PLC 5/11,20,30,40,60,80 (RS 232) 1) 2) 1) 2) 1) 2) 1) 2) 1784 CP10 7)
See FAQ 9)
PLC 5/11,20,30,40,60,80 (RS 422) 1) 1) 1) 1) See FAQ 9)
via KF2 gateway and
DH+ network with up to
4xSLC 50/04 or
PLC 5/11,20,30,40,60,80 (RS 232)
1) 2) 1) 2) 1) 2) 1) 2) 1784 CP10 7) 8)
See FAQ 9)
via KF2 gateway and
DH+ network with up to
4xSLC 50/04 or
PLC 5/11,20,30,40,60,80 (RS 422)
1) 1) 1) 1) See FAQ 9)
via KF3 gateway and
DH485 network with up to
4xSLC 500/00,01,02,03,04,05 or
MicroLogix (RS 232)
1) 2) 1) 2) 1) 2) 1) 2) 1784 CP10 7)8)
See FAQ 9)
Allen Bradley (DH485)
SLC 500/03,04,05 or
MicroLogix (RS 232) 1) 2) 1) 2) See FAQ 9)
via AIC adapter and
DH485 network with up to
4 x SLC 500 or MicroLogix
(RS 232)
1) 2) 1) 2) See FAQ 9)
via DH485 network with up to
4 x SLC 500/00,01,02,03,04,05 or
MicroLogix (RS 485)
1) 1) See FAQ 9)
Allen Bradley (Ethernet IP)
via Ethernet IPnetwork
with up to 4 x ControlLogix
(1756-L61, 1756-L62, 1756-L63,
1756-L64, 1756-L65, each with
Ethernet module 1756-ENBT)
GuardLogix
(1756-L61S, 1756-L62S,
1756-L61S, each with Ethernet
module 1756-ENBT) or
CompactLogix
(1769-L32E, 1769-L35E, each with
Ethernet interface onboard
3) 4) 4) See FAQ 9)
ST80_2013_EN_Kap02.book Seite 92 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
System interfaces with WinCC flexible
PLCs from other manufacturers
2/93
Siemens ST 80 / ST PC · 2013
Overview (continued)
2
System interface possible
– System interface not possible
1) Not Mobile Panel 177 PN, Mobile Panel 277 IWLAN; Mobile Panel 177 DP,
Mobile Panel 277 connection via special connecting cable and junction
box (see Mobile Panel); see manual for cable assignment.
2) The RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is required for Touch
Panels, Operator Panels, and Multi Panels
3) With connection using a Mitsubishi PC cable, an 15-pin/9-pin adapter
6XV1 440-2UE32 is required
4) Detailed information (cables used) see FAQ:
http://support.automation.siemens.com/WW/view/de/29034071 in the
online help for WinCC flexible and in the Communication User Manual for
Windows-based systems
5) Mitsubishi PC cable with integrated level converter RS 232/RS 422
6) WinCC flexible 2008 Service Pack 2 and higher
Controller SIMATIC HMI
Target hardware (PROTOCOL)
(physics) OP 77A
TP 177A
Basic Panel OP 77B
TP 177B DP
OP 177B DP
TP 177B DP/PN
OP 177B DP/PN
Mobile Panel 177 DP
Mobile Panel 177 PN
TP 277
OP 277
Mobile Panel 277
Mobile Panel 277
IWLAN
MP 177
MP 277
MP 377
WinCC flexible
Runtime Connection via
GE-Fanuc (SNP)
GEF 90-Micro, 90-30, 90-70
(RS 232) 1) 2) 1) 2) See FAQ 4)
via adapter with up to 4 x GEF
90-Micro, 90-30, 90-70 (RS 232) 1) 2) 1) 2) See FAQ 4)
via adapter with up to 4 x GEF
90-Micro, 90-30, 90-70 (RS 422) 1) 1) See FAQ 4)
LG GLOFA (Dedicated)
GLOFA-GM with Cnet module
(RS 232) 1) 2) 1) 2) See FAQ 4)
With up to 4 x GLOFA-GM with
Cnet module (RS 422) 1) 1) See FAQ 4)
Mitsubishi FX
FX0 (RS 422) – – SC-09 6)
1) 1) See FAQ 4)
FX0n, FX1n, FX2n (RS 422) – – SC-09 6)
1) 1) See FAQ 4)
FX1N-14MR-DS 1) 6) 1) 6) SC-09 6)
FX1S-10MR-DS
FX2N-16MR-DS (RS 422)
Mitsubishi (MP4)
Series FX
with communications module 1) 2) 1) 2) See FAQ 4)
Series A (AnN, AnA, AnU, AnS)
with interface module
Series Q (QnA, QnAS) with
interface module (RS 232)
via FX-48SC-IF converter
with up to 4 PLCs 1) 2) 1) 2) See FAQ 4)
Series FX with communications
module
Series A (AnN, AnA, AnU, AnS)
with interface module
Series Q (QnA, QnAS) with
interface module (RS 232)
with up to 4 PLCs 1) 1) See FAQ 4)
Series FX
with communications module
Series A (AnN, AnA, AnU, AnS)
with interface module
Series Q (QnA, QnAS) with
interface module (RS 422)
ST80_2013_EN_Kap02.book Seite 93 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
System interfaces with WinCC flexible
PLCs from other manufacturers
2/94 Siemens ST 80 / ST PC · 2013
Overview (continued)
2
System interface possible
System interface not possible
1) Not Mobile Panel 177 PN, Mobile Panel 277 IWLAN; Mobile Panel 177 DP,
Mobile Panel 277 connection via special connecting cable and
junction box (see Mobile Panel); see manual for cable assignment.
2) The RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is required for
Touch Panels, Operator Panels, and Multi Panels
3) Only TP 177B DP/PN, OP 177B DP/PN, Mobile Panel 177 PN
4) Mobile Panel 177 PN, Mobile Panel 277 connection via special connecting
cable and junction box (see Mobile Panel); see manual for cable
assignment.
5) Not Mobile Panel 277 IWLAN (wireless interface, see Mobile Panel)
6) Connection via integrated Industrial Ethernet interface; use the CP 1612
with a standard PC
7) Detailed information (cables used) see FAQ:
http://support.automation.siemens.com/WW/view/en/29034071 in the
online help for WinCC flexible and in the Communication User Manual for
Windows-based systems
8) WinCC flexible 2008 Service Pack 2 and higher
Controller SIMATIC HMI
Target hardware (PROTOCOL)
(physics) OP 77A
TP 177A
Basic Panel OP 77B
TP 177B DP
OP 177B DP
TP 177B DP/PN
OP 177B DP/PN
Mobile Panel 177 DP
Mobile Panel 177 PN
TP 277
OP 277
Mobile Panel 277
Mobile Panel 277
IWLAN
MP 177
MP 277
MP 377
WinCC flexible
Runtime Connection via
Modicon (Modbus)
984-120, 130, 131, 141, 145,
380, 381, 185, 480, 485, 680,
685, 780, 785, or
TSX-Quantum-CPU 113, 213,
424, 434, 534 (RS 232)
1) 2) 1) 2) 1) 2) 1) 2) See FAQ 7)
via bridge BM85-000 or
PLC with bridge function. /
Modbus PLUS network
with up to 4 x 984-120, ... or
TSX Quantum - CPU 113, or
TSX Contact
(RS 232)
1) 2) 1) 2) 1) 2) 1) 2) See FAQ 7)
TSX Compact (RS 232) 1) 2) 1) 2) 1) 2) 1) 2) See FAQ 7)
Modicon (Modbus TCP/IP)
via Modbus TCP/IP network
with up to 4 x
TSX Unity Quantum or
TSX Unity Premium or
TSX Quantum or
TSX Quantum with TCP/IP
module 140 NOE 771 01 or
TSX Unity Premium or
TSX Premium with
TCP/IP module TSX ETY 110
or TSX Micro with
TCP/IP module TSX ETY 410
or Momentum with
CPU adapter 171 CCC 980 30
3) 4) 4) 5)
via TCP/IP ModbusPlus bridge
174 CEV 200 40 / Modbus PLUS
network with up to 4 x
TSX Unity Quantum or
TSX Quantum or
TSX Compact or 984-120, ...
(except 984A, 984B, 984X )
3) 4) 4) 5)
via Modbus TCP/IP network
with up to 4 x
TSX Unity Quantum or
TSX Unity Premium or
TSX Quantum or
TSX Quantum with TCP/IP
module 140NOE 771 01 or
TSX Unity Premium or
TSX Premium with TCP/IP
module TSX ETY 110 or
TSX Micro with TCP/IP module
TSX ETY 410 or
Momentum with CPU adapter
171 CCC 980 30
3) 8) 3) 8) – –
via TCP/IP ModbusPlus Bridge
174 CEV 200 40 / Modbus PLUS
network with up to 4 x
TSX Unity Quantum or
TSX Quantum or
TSX Compact
3) 8) 3) 8) – –
ST80_2013_EN_Kap02.book Seite 94 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
System interfaces with WinCC flexible
PLCs from other manufacturers
2/95
Siemens ST 80 / ST PC · 2013
Overview (continued)
2
System interface possible
– System interface not possible
1) Not Mobile Panel 177 PN, Mobile Panel 277 IWLAN; Mobile Panel 177 DP,
Mobile Panel 277 connection via special connecting cable and junction
box (see Mobile Panel); see manual for cable assignment.
2) The RS 422/RS 232 adapter 6AV6 671-8XE00-0AX0 is required for
Touch Panels, Operator Panels, and Multi Panels
3) Detailed information (cables used) see FAQ:
http://support.automation.siemens.com/WW/view/en/29034071 in the
online help for WinCC flexible and in the Communication User Manual for
Windows-based systems
4) WinCC flexible 2008 Service Pack 2 and higher
Controller SIMATIC HMI
Target hardware (PROTOCOL)
(physics) OP 77A
TP 177A
Basic Panel OP 77B
TP 177B DP
OP 177B DP
TP 177B DP/PN
OP 177B DP/PN
Mobile Panel 177 DP
Mobile Panel 177 PN
TP 277
OP 277
Mobile Panel 277
Mobile Panel 277
IWLAN
MP 177
MP 277
MP 377
WinCC flexible
Runtime Connection via
Omron (Link/MultiLink)
SYSMAC C
(except CPU CQM1 – CPU 11/21)
SYSMAC Alpha
SYSMAC CV (RS 232)
1) 2) 1) 2) See FAQ 3)
via NT-AL001 converter
with up to 4 PLCs
SYSMAC C
(except CPU CQM1 – CPU 11/21)
SYSMAC Alpha
SYSMAC CV (RS 232)
1) 2) 1) 2) See FAQ 3)
with up to 4 PLCs
SYSMAC C
(except CPU CQM1 – CPU 11/21)
SYSMAC Alpha
SYSMAC CV (RS 422)
1) 1) See FAQ 3)
• CP1L-L14DT1-D 1) 4) 1) 4) – –
• C1H-Y20DT-D
• CJ1M CPU11
Telemecanique (UNI-TELWAY)
via TSX SCA62 outlet with
TSX 17 or TSX 47/67/87/107 (RS 485) 1) 1) See FAQ 3)
via TSX SCA62 + ACC01 outlets
with TSX 37/57 (RS 485) 1) 1) See FAQ 3)
via TSX SCA62 outlet and
UNI-TELWAY network with
4xTSX 17 or TSX 37/57 (+ACC 01)
or TSX 47/67/87/107 (RS 485)
1) 1) See FAQ 3)
ST80_2013_EN_Kap02.book Seite 95 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIMATIC HMI accessories
General HMI accessories
2/96 Siemens ST 80 / ST PC · 2013
2
Overview
Industrial USB Hub 4
Touchscreen stylus and touch pen
The specially coordinated range of accessories supplements
the SIMATIC HMI core products perfectly. Industrial Hub 4 can
be used, for example, to make a USB port available to the user
exactly where it is required. Touch pens can be used to operate
extremely small buttons, and they also ensure that the display
stays clean for longer.
SIMATIC HMI accessories can also be used in non-Siemens
devices; see the technical specifications for more detailed infor-
mation.
General SIMATIC HMI accessories for all currently available
Panels are listed in this chapter; the full range of SIMATIC HMI
accessories is available in the Mall and in our other online
media.
ST80_2013_EN_Kap02.book Seite 96 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIMATIC HMI accessories
Industrial USB Hub 4
2/97
Siemens ST 80 / ST PC · 2013
2
Overview
The Industrial USB Hub 4 is used as a USB port extender
(4 in 1) for the connection of peripheral devices to USB 2.0
interfaces of Comfort Panels, Multi Panels, IPCs, and standard
PCs.
The Industrial USB Hub 4 (IP65 degree of protection on the
front, service kit may be required) can also be mounted
directly in a control cabinet.
With the USB Hub 4, the USB port can be moved forwards to
the control cabinet door, making it accessible without opening
the cabinet door
The USB Hub 4 can also be mounted on a standard mounting
rail in the control cabinet, in which case it serves as a simple
interface multiplier
Technical specifications
Ordering data Order No.
More information
Note for SIMATIC Panel PCs
The Industrial USB Hub 4 is approved for the Windows CE/2000/
XP/Windows 7 operating systems. The appropriate drivers are
supplied with the operating system software.
6AV6671-3AH00-0AX0
Industrial USB Hub 4
Installation type/mounting
Mounting rail installation possible Yes; Standard - DIN rail
Mounting in landscape format
possible Yes
Supply voltage
Type of supply voltage 24 V DC
Rated voltage/DC 24 V
permissible range, lower limit (DC) 20.4 V
permissible range, upper limit (DC) 28.8 V
Interfaces
Number of USB interfaces 4; Type USB 2.0, 500 mA each;
e.g. connection of mouse,
keyboard, printer, USB stick,
USB IPC flash drive
Degree and class of protection
Type of protection 20
IP (at the front) 65
Standards, approvals, certificates
CE Yes
Ambient conditions
Operating temperature
• Operation (vertical installation) 0 °C to +50 °C
- in vertical mounting position/
minimum C
- in vertical mounting position/
maximum 50 °C
Storage/transport temperature
•Min. -20 °C
•max. 60 °C
Relative humidity
max. relative humidity 90 %
Mechanics/material
Type of housing (front)
• Plastic Yes
Dimensions
Width of the housing front 212 mm
Height of housing front 156 mm
Depth/installation dimension 50 mm
Weight
Weight without packaging 460 g
Scope of supply
Delivery unit in items 1; Content: 1 X USB Hub 4,
10 x plastic mounting clip,
1 x female 2-pin connector
other
Note: for access to the USB interface of
a built-in device without having to
open the control cabinet, mounting
on standard rail possible, suitable
for standard USB interfaces
6AV6671-3AH00-0AX0
Industrial USB Hub 4
Industrial USB Hub 4 6AV6671-3AH00-0AX0
4 x USB 2.0, IP65, for control cabi-
net door or standard rail, for use
with MP 177/MP 277/MP 377, Panel
PCs, HMI IPCs and standard PCs
Service set for Industrial USB
Hub 4 (incl. IP65 expansion) See HMI accessories service sets,
from page 2/118
ST80_2013_EN_Kap02.book Seite 97 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIMATIC HMI accessories
Touch pen and touch stylus
2/98 Siemens ST 80 / ST PC · 2013
2
Overview
Optional package: Touchscreen stylus and touch pen
If you are working with gloves, touch pens are often extremely
useful when operating touch displays. They protect the display
from dirt and scratching during operation and use. They are also
useful for operating small buttons or input fields accurately.
Technical specifications
Ordering data Order No.
Note:
This catalog only includes accessories for current products.
The complete range of accessories can be found in the Mall:
https://eb.automation.siemens.com
or on our SIMATIC Support pages:
http://support.automation.siemens.com
6AV7672-1JB00-0AA0 6AV6645-7AB14-0AS0
Touch pen, thick, resistive technology Touch pen, thin, resistive technology
Installation type/mounting
Wall mounting/direct mounting possible Yes; Terminal holder can be attached Yes; using 40 cm retaining cord
Standards, approvals, certificates
CE Yes Yes
Ambient conditions
Operating temperature
Operating temperature range, max. 55 °C 55 °C
Operating temperature range, min. C 0°C
Storage/transport temperature
•Min. -20 °C -20 °C
•max. 70 °C 70 °C
Relative humidity
max. relative humidity 90 % 90 %
Mechanics/material
Screw type
•Torx Yes
Plastic Yes Yes
Dimensions
Height 155 mm; Length 125 mm; Length
Thickness 20 mm; Diameter 8 mm; Diameter
Scope of supply
Delivery unit in items 1; Optional for extension units of the PRO devices 5; Incl. retaining cord for Mobile Panel 277 10"
other
Note: for resistive touch screens, optimized for operating
while wearing gloves for resistive touch screens
Touch stylus 6AV7672-1JB00-0AA0
for Panels, Panel PC, Touch Monitor
and other touch applications,
including screw-on wall holder
•1unit
Touch pen 6AV6645-7AB14-0AS0
Specially designed for
Mobile Panel 277 10",
but also other touch displays,
including attachment cord
•5units
ST80_2013_EN_Kap02.book Seite 98 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Mobile Panel accessories
SIMATIC Mobile Panel accessories
2/99
Siemens ST 80 / ST PC · 2013
2
Overview
Mobile Panel accessories
General Mobile Panel accessories, such as service sets and
protective membranes, are listed in the respective accessories
section.
Special Mobile Panel accessories are listed in the following
section.
System components for SIMATIC HMI Mobile Panels can be
found directly under the respective Mobile Panel in the products
section.
ST80_2013_EN_Kap02.book Seite 99 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Mobile Panel accessories
Power supply unit
2/100 Siemens ST 80 / ST PC · 2013
2
Overview
The external power supply for the Mobile Panel IWLAN is
intended for laboratory and office operation.
Suitable SITOP power supplies are available for use with
machinery and plants.
Technical specifications
Ordering data Order No.
Note:
This catalog only includes accessories for current products.
The complete range of accessories can be found in the Mall:
https://eb.automation.siemens.com
or on our SIMATIC Support pages:
http://support.automation.siemens.com
6AV6671-5CN00-0AX2
Power pack, external,
Mobile Panel IWLAN
Supply voltage
Type of supply voltage 100-240 V AC
Rated voltage/DC 12 V; Output side
Input current
Current consumption (rated value) 1.5 A; 50-60 Hz
Output current
each output 5A
Power
Output power 60 W
Interfaces
HMI-side interface Connector 5.5 mm jack ( -) /
2.1 mm pin ( +) 12 V DC
EMC
Emission of radio interference
acc. to EN 55 011
Emission of radio interferences
acc. to EN 55 011 (limit class A) Yes; EN61000-4-2,3,4,5,6,8,11
light industry level
Standards, approvals, certificates
CE Yes; UL69950, TÜVEN600950-1,
BSMI CNS14336,
CCC GB4942 approved
Ambient conditions
Operating temperature
Operating temperature range, max. 50 °C
Operating temperature range, min. -10 °C
Storage/transport temperature
•Min. -20 °C
•max. 85 °C
Relative humidity
max. relative humidity 90 %
Vibrations
•Vibration 2g; 10 min./1 cycle
• Frequency 500 Hz; 10~500 Hz
Mechanics/material
Type of housing (front)
• Plastic Yes
Dimensions
Width 125 mm
Height 50 mm
Thickness 31.5 mm
Weight
Weight without packaging 305 g
Scope of supply
Delivery unit in items 1; Incl. AC and DC connecting
cable
Number of sets 4; AC cable for EU, US, UK and JP
other
Note: for Mobile Panel IWLAN
6AV6671-5CN00-0AX2
Power pack, external,
Mobile Panel IWLAN
Accessories for
Mobile Panel 277(F) IWLAN
Power supply unit, external,
Mobile Panel IWLAN 6AV6671-5CN00-0AX2
Only suitable for operation under
laboratory/office conditions.
ST80_2013_EN_Kap02.book Seite 100 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Mobile Panel accessories
Additional accessories
2/101
Siemens ST 80 / ST PC · 2013
2
Overview
Wall-mounting bracket for Mobile Panel, front view
Spare keys for Mobile Panel
Moby D data card transponder
Technical specifications
6AV6574-1AF04-
4AA0 6AV6574-1AG04-
4AA0
Wall-mounting
bracket
Mobile Panel
Spare key
Mobile Panel
Installation type/mounting
Mounting in portrait format
possible Yes
Mounting in landscape format
possible No
Standards, approvals,
certificates
CE Yes Yes
Ambient conditions
Operating temperature
Operating temperature range,
max. 55 °C 55 °C
Operating temperature range,
min. C 0°C
Storage/transport temperature
•Min. -20 °C -20 °C
•max. 70 °C 70 °C
Relative humidity
max. relative humidity 90 % 90 %
Mechanics/material
Sheet steel Yes; Handle made
of plastic
Type of housing (front)
• Sheet steel Yes; Powder-coated
Dimensions
Width 200 mm 35 mm
Height 230 mm 18 mm
Thickness 4mm
Depth 25 mm;
Constructive
Weight
Weight without packaging 550 g; 880 g incl.
cable holder 30 g
Scope of supply
Delivery unit in items 1; Color: Black 10; Coupled with
key ring
other
Note: Mobile Panel 170,
Mobile Panel 177,
Mobile Panel 277
IWLAN, Mobile
Panel 277F IWLAN,
without mounting
parts
For all
Mobile Panels with
key-operated switch
ST80_2013_EN_Kap02.book Seite 101 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Mobile Panel accessories
Additional accessories
2/102 Siemens ST 80 / ST PC · 2013
2
Ordering data Order No. Order No.
Wall mounting bracket
for Mobile Panels 6AV6574-1AF04-4AA0
metal, without mounting accesso-
ries, suitable for all Mobile Panels
•1unit
Replacement keys
for Mobile Panels 6AV6574-1AG04-4AA0
metal/plastic, for all Mobile Panels,
two linked by keyring
•10 units
SCALANCE
SCALANCE W-788 Access Points
IWLAN Access Points with built-in
wireless interface; wireless networks
IEEE 802.11b/g/a/h at 2.4/5 GHz to
54 Mbps; national approvals;
WPA2/AES; Power over Ethernet
(PoE), degree of protection IP65
(-20°C to +60°C);
scope of delivery: 2 ANT795-4MR
antennas, IP 67 hybrid connector,
installation material, manual on
CD-ROM, English/German
SCALANCE W788-2RR
IWLAN Dual Access Point with two
built-in radio interfaces for establish-
ment of radio connections with iPCF
National approvals for
operation outside the U.S.1) 2) 6GK5788-2AA60-6AA0
National approvals for
operation within the U.S. 2) 6GK5788-2AA60-6AB0
SCALANCE W788-1PRO
IWLAN Access Point with
one built-in wireless interface
National approvals for
operation outside the U.S. 1) 6GK5788-1AA60-2AA0
National approvals for
operation within the U.S. 6GK5788-1AA60-2AB0
1) RoW version: "Rest of World" version: Version for sale worldwide, apart
from in the USA.
2) Already prepared for rapid roaming (iPCF-MC); iPCF-MC is already
included as of SCALANCE FW version V4.3.37.
SCALANCE W-786 Access Points
for SIMATIC Mobile Panel 277(F)
IWLAN
IWLAN Access Points with
integrated wireless interfaces;
wireless networks;
IEEE 802.11b/g/a/h at 2.4/5 GHz
up to 54 Mbps. National approvals;
WPA2/AES; Power over Ethernet
(PoE), degree of protection IP65
(-40 °C to +70 °C); scope of
delivery: Mounting hardware,
48 V DC terminal block; manual
on CD-ROM; English/German
SCALANCE W-786-2RR
IWLAN Dual Access Point with two
integrated wireless interfaces for
setting up radio connections with
iPCF; RJ45 connection
Four internal antennas
• National approvals for
operation outside the U.S.1) 2) 6GK5786-2BA60-6AA0
• National approvals for
operation within the U.S. 2) 6GK5786-2BA60-6AB0
SCALANCE W-786-1PRO
IWLAN Access Points with built-in
wireless interface RJ45 connection
Two internal antennas
• National approvals for
operation outside the U.S. 1) 6GK5786-1BA60-2AA0
• National approvals for
operation within the U.S. 6GK5786-1BA60-2AB0
SCALANCE W-784 Access Points
IWLAN Access Points with built-in
wireless interfaces;wireless
networks IEEE 802.11b/g/a/h at
2.4/5 GHz to 54 Mbps. National
approvals; WPA2/AES; Power over
Ethernet (PoE), IP30 degree of
protection (-20 °C to +60 °C);
scope of supply: Installation
material, 24 V DC terminal block;
manual on CD-ROM
English/German
SCALANCE W784-1
IWLAN Access Points with
one built-in wireless interface
• National approvals for
operation outside the U.S. 1) 6GK5784-1AA30-2AA0
• National approvals for
operation within the U.S. 6GK5784-1AA30-2AB0
ST80_2013_EN_Kap02.book Seite 102 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
Mobile Panel accessories
Additional accessories
2/103
Siemens ST 80 / ST PC · 2013
Ordering data Order No.
2
This catalog only includes accessories for current products.
The complete range of accessories can be found in the Mall:
https://eb.automation.siemens.com
or on our SIMATIC Support pages:
http://support.automation.siemens.com
Further IWLAN Access Point
versions
SCALANCE W-784 Access Points 6GK5784-1AA30-...
IWLAN Access Points with
integrated wireless interfaces
(see Catalog IK PI), wireless
networks IEEE 802.11b/g/a/h at
2.4/5 GHz up to 54 Mbps. National
approvals; WPA2/AES; Power over
Ethernet (PoE), degree of protec-
tion IP30 (-20 °C to +60 °C); scope
of delivery: Installation material,
24 V DC terminal block; manual on
CD-ROM; English/German;
(see Catalog IK PI)
SCALANCE W-786 Access Points 6GK5786-...
IWLAN Access Points with
integrated wireless interfaces
(see Catalog IK PI); wireless
networks IEEE 802.11b/g/a/h at
2.4/5 GHz up to 54 Mbps. National
approvals; WPA2/AES; Power over
Ethernet (PoE), degree of protec-
tion IP65 (-40°C to +70°C); scope of
delivery: Installation material,
48 V DC terminal block; manual on
CD-ROM; English/German;
(see Catalog IK PI)
SCALANCE W-788 Access Points 6GK5788-...
IWLAN Access Points with
integrated wireless interfaces
(see Catalog IK PI); wireless
networks IEEE 802.11b/g/a/h at
2.4/5 GHz up to 54 Mbps. National
approvals; WPA2/AES; Power over
Ethernet (PoE), degree of protec-
tion IP65 (-20°C to +60°C); scope of
delivery: 2 ANT795-4MR antennas,
IP67 hybrid plug-in connector,
installation material, manual on
CD-ROM, English/German
(see Catalog IK PI)
PS791-2DC power supply 6GK5791-2DC00-0AA0
24 V DC power supply for installa-
tion in SCALANCE W-786 products;
operating instructions in English/
German
PS791-2AC power supply 6GK5791-2AC00-0AA0
110 V AC to 230 V AC power supply
for installation in SCALANCE W-786
products; operating instructions in
English/German
MOBY D accessories
MOBY D, MDS D100 6GT2600-0AD10
•1 unit
Spacer 6GT2190-0AA00
•1 unit
Fixing pocket 6GT2190-0AB00
•1 unit
Dimensional drawings
SIMATIC Mobile Panel wall-mounting bracket
100.7
24.6
18
225.2
2
G_ST80_XX_00047
ST80_2013_EN_Kap02.book Seite 103 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIMATIC HMI accessories
Connectors/converters/adapters
2/104 Siemens ST 80 / ST PC · 2013
2
Overview
Connectors/converters/adapters
Components for the connection of SIMATIC HMI Panels
The range comprises connectors, adapters, converters, and
transducers.
An adapter can be used, for example, to mechanically rotate the
connector of a 9-pin panel plug by 90°. This may be beneficial
in confined spaces in the control desk or installation cabinet,
and is an easy way to provide additional flexibility.
A converter can be used to simulate a connection type that is
missing at the panel. In this way, for example, a TTY (20 mA) can
be generated from an RS422 signal, which is required for
connection to various types of PLC. Connectors are required for
power supply and I/O.
2-pin to n-pin connectors
• Converters
• Transducers
Adapters for changing the cable outlet direction
Bus connector
SIMATIC HMI accessories can also be used on non-Siemens
devices; see the technical specifications for more detailed infor-
mation.
General SIMATIC HMI accessories are listed in this subsection;
the full range of SIMATIC HMI accessories is available in the Mall
and in our other online media.
ST80_2013_EN_Kap02.book Seite 104 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
HMI connecting components
2/105
Siemens ST 80 / ST PC · 2013
2
Overview
RS 422 to RS 232 converter
RS 422 to TTY converter
90 degree angle adapter, 1:1
Connector, female, 16-pin, I/O
Connector, female, 2x2-pin, jumpered internally
Connector, female, 2-pin
For:
Push Button Panels
Key Panels
Text Displays
Operator Panels
Touch Panels
Multi Panels
Basic Panels
Comfort Panels
Mobile Panels
Thin Clients
Industrial USB Hub
ST80_2013_EN_Kap02.book Seite 105 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
HMI connecting components
2/106 Siemens ST 80 / ST PC · 2013
2
Technical specifications
6AV6671-8XA00-0AX0 6ES7193-4JB00-0AA0
Connector, female, 2-pin Connector, female, 2x2-pin
Installation type/mounting
Wall mounting/direct mounting possible Yes; can be plugged into SIMATIC HMI device Yes; can be plugged into SIMATIC HMI device
Supply voltage
Rated voltage/DC 24 V; DC 24 V; DC
Interfaces
Number of pins HMI-side 2; Female 2; Outgoing side jumpered internally, color-coded
Number of pins device-side 2; Female, screw terminals 4; Female, spring-loaded terminals, 0.75 mm2
Standards, approvals, certificates
CE Yes Yes
Ambient conditions
Operating temperature
Operating temperature range, max. 55 °C 55 °C
Operating temperature range, min. C C
Storage/transport temperature
•Min. -20 °C -20 °C
•max. 70 °C 70 °C
Relative humidity
max. relative humidity 95 % 95 %
Mechanics/material
Screw type
•4.5 V Yes
Type of housing (front)
• Plastic Yes Yes
Dimensions
Width 10 mm 10 mm
Height 15 mm 22 mm
Thickness 27 mm 25 mm
Scope of supply
Delivery unit in items 10 10
other
Note: for SIMATIC HMI Panels, except for Key Panel for ET 200S, interface module, KP32F, PN-to-PN coupler
6AV6671-3XY38-4AX0 6AV6671-3XY48-4AX0 6AV6671-3XY58-4AX0
Connector, female, 12-pin Connector, female, 16-pin Connector, female, 24-pin
Installation type/mounting
Wall mounting/direct mounting possible Yes; can be plugged into
SIMATIC HMI device Yes; can be plugged into
SIMATIC HMI device Yes; can be plugged into
SIMATIC HMI device
Supply voltage
Rated voltage/DC 24 V; DC 24 V; DC 24 V; DC
Interfaces
Number of pins HMI-side 12; Female 16; Female 24; Female
Number of pins device-side 12; Female, spring-loaded terminals 16; Female, spring-loaded
terminals, 0.75 mm2 24; Female, spring-loaded
terminals, 0.75 mm2
Standards, approvals, certificates
CE Yes Yes Yes
Ambient conditions
Operating temperature
Operating temperature range, max. 55 °C 55 °C 55 °C
Operating temperature range, min. C C C
Storage/transport temperature
•Min. -20 °C -20 °C -20 °C
•max. 70 °C 70 °C 70 °C
Relative humidity
max. relative humidity 95 % 95 % 95 %
Mechanics/material
Type of housing (front)
• Plastic Yes Yes Yes
ST80_2013_EN_Kap02.book Seite 106 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
HMI connecting components
2/107
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
Dimensions
Width 16 mm 16 mm 16 mm
Height 20 mm 28 mm 54 mm
Thickness 20 mm 20 mm 20 mm
Scope of supply
Delivery unit in items 10; Without ejector 10; Without ejector 4; Without ejector
other
Note: for KP8 PN for KP8F PN, KP32F PN for KP32F PN
6AV6671-8XE00-0AX0 6AV6671-8XJ00-0AX0 6AV6671-8XD00-0AX0
Converter, RS 422 to RS 232 Converter RS 422 to TTY 90 degree angle adapter, 1:1
Installation type/mounting
Wall mounting/direct mounting possible Yes; Can be screwed onto the HMI Yes; Can be screwed onto the HMI Yes; Can be screwed onto the HMI
Interfaces
Number of pins HMI-side 9; Pin (RS422) 9; Pin (RS422) 9; Male
Number of pins device-side 9; Pin (RS232) 15; Socket (TTY) 9; Female
Standards, approvals, certificates
CE Yes Yes Yes
Ambient conditions
Operating temperature
Operating temperature range, max. 55 °C 55 °C 55 °C
Operating temperature range, min. C C C
Storage/transport temperature
•Min. -20 °C -20 °C -20 °C
•max. 70 °C 70 °C 70 °C
Relative humidity
max. relative humidity 95 % 95 % 95 %
Mechanics/material
Screw type
•4.5 V Yes; HMI page Yes; HMI page Yes; HMI page
Type of housing (front)
• Plastic Yes Yes
Cast light alloy Yes
Dimensions
Width 31 mm 42 mm 31 mm
Height 50 mm 62 mm 25 mm
Thickness 11 mm 11 mm 25 mm
Weight
Weight without packaging 26 g 28 g 34 g
Scope of supply
Delivery unit in items 1 1 1
other
Note: suitable for all SIMATIC HMI RS422
interfaces, for details refer to the
operating instructions of the
respective device
suitable for all SIMATIC HMI RS422
interfaces, for details refer to the
operating instructions of the
respective device
suitable for all appropriate interfaces
6AV6671-3XY38-4AX0 6AV6671-3XY48-4AX0 6AV6671-3XY58-4AX0
Connector, female, 12-pin Connector, female, 16-pin Connector, female, 24-pin
ST80_2013_EN_Kap02.book Seite 107 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
HMI connecting components
2/108 Siemens ST 80 / ST PC · 2013
2
Ordering data Order No. Order No.
Note:
Delivery units/quantities are specified in the applicable technical
data.
This catalog only includes accessories for current products.
The complete range of accessories can be found in the Mall:
https://eb.automation.siemens.com
or on our SIMATIC Support pages:
http://support.automation.siemens.com
Connectors
24 V DC connector (2-pin) 6AV6671-8XA00-0AX0
for all SIMATIC HMI Panels, without
screw mounting, loop-through not
possible.
Approved for all SIMATIC HMI
Panels except Key Panels.
24 V DC connector (2-pin)
(can be looped through) 6ES7193-4JB00-0AA0
for all SIMATIC HMI Panels, without
screw mounting, loop through possi-
ble, even if connecter unplugged.
Approved for Key Panels.
12-pin cable connector 6AV6671-3XY38-4AX0
12-pin, 24 V DC for
SIMATIC HMI Key Panel KP8 PN
16-pin cable connector 6AV6671-3XY48-4AX0
16-pin, 24 V DC for
SIMATIC HMI Key Panel KP8F PN
and Key Panel KP32F PN
24-pin cable connector 6AV6671-3XY58-4AX0
24-pin, 24 V DC for
SIMATIC HMI Key Panel KP32F PN
Converters
RS422 to RS232 converter 6AV6671-8XE00-0AX0
9-pin male contact (on HMI) to 9-pin
male contact, to be screwed onto
HMI RS422 interface, cable outlet
180 degrees, for connection of
non-Siemens PLC
RS422 to TTY converter 6AV6671-8XJ00-0AX0
9-pin male contact (on HMI) to
15-pin female contact, to be
screwed onto HMI RS422 interface,
180 degree cable outlet,
for the connection to SIMATIC S5
Adapters
90 degree angle adapter 6AV6671-8XD00-0AX0
9-pin male contact (on HMI) to 9-pin
female contact, 1:1 connection, to
be screwed onto the RS485/422/232
HMI interface, or any other suitable
interface
ST80_2013_EN_Kap02.book Seite 108 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
RS485 bus connector
2/109
Siemens ST 80 / ST PC · 2013
2
Overview
Used for connecting PROFIBUS nodes to the PROFIBUS bus
cable
Easy installation
FastConnect plugs ensure extremely short assembly times
due to their insulation-displacement technology
Integrated terminating resistors (not in the case of
6ES7 972-0BA30-0XA0)
Connectors with Sub-D socket permit PG connection without
the additional installation of network nodes
Ordering data Order No. Order No.
RS485 bus connector
with axial cable outlet (180°) 6GK1500-0EA02
For industrial PC, SIMATIC HMI OP,
OLM; max. transmission rate
12 Mbit/s
SIPLUS DP PB RS485 connector
with axial cable outlet (180°) 6AG1500-0EA02-2AA0
For medial stress;
Based-on 6GK1 500-0EA02
RS485 bus connector
with cable outlet (90°)
With screw-terminals, max. trans-
mission rate 12 Mbit/s
without PG interface 6ES7972-0BA12-0XA0
with PG interface 6ES7972-0BB12-0XA0
SIPLUS DP PB RS485 connector
with 90° cable outlet
For extended temperature range
-25 … + 60 °C
without PG interface
Based on 6ES7 972-0BA12-0XA0 6AG1972-0BA12-2XA0
with PG interface
Based on 6ES7 972-0BB12-0XA0 6AG1972-0BB12-2XA0
RS485 bus connector
with angled cable outlet (35°)
With screw-terminals, max.
transmission rate 12 Mbit/s
without PG interface 6ES7972-0BA42-0XA0
with PG interface 6ES7972-0BB42-0XA0
SIPLUS DP PB RS485 connector
with inclined cable outlet (35°)
For extended temperature range
-25 … + 60 °C
without PG interface
Based on 6ES7 942-0BA42-0XA0 6AG1972-0BA42-7XA0
with PG interface
Based on 6ES7 942-0BB42-0XA0 6AG1972-0BB42-7XA0
RS485 bus connector
with cable outlet (30°) 6ES7972-0BA30-0XA0
With screw-terminals,
low-cost variant,
max. transmission rate 1.5 Mbit/s
PROFIBUS bus connector RS485
with FastConnect technology
PROFIBUS FastConnect bus con-
nector RS485 with 90° cable outlet
With insulation displacement, max.
transmission rate 12 Mbps
Without PG interface
•1 unit 6ES7972-0BA52-0XA0
100 units 6ES7972-0BA52-0XB0
With PG interface
•1 unit 6ES7972-0BB52-0XA0
100 units 6ES7972-0BB52-0XB0
Without PG interface, grounding
via control cabinet cover
•1 unit 6ES7972-0BA70-0XA0
With PG interface, grounding
via control cabinet cover
•1 unit 6ES7972-0BB70-0XA0
PROFIBUS FastConnect RS485
bus connector with angled cable
outlet (35°)
With insulation displacement,
max. transmission rate 12 Mbps
without PG interface 6ES7972-0BA60-0XA0
with PG interface 6ES7972-0BB60-0XA0
PROFIBUS FastConnect
bus connector RS485 Plug 180 6GK1500-0FC10
With insulation displacement
terminals, with 180° cable outlet,
for industrial PC, SIMATIC HMI OP,
OLM; max. transmission rate
12 Mbit/s
SIMATIC S5/S7 plug-in cable for
PROFIBUS 6ES7901-4BD00-0XA0
Preassembled with two 9-pin sub-D
connectors; max. transmission rate
12 Mbit/s; 3 m
SIMATIC NET Manual Collection 6GK1975-1AA00-3AA0
Electronic manuals for communica-
tion systems, communication proto-
cols, and communication products;
on DVD; German/English
ST80_2013_EN_Kap02.book Seite 109 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
IE FC RJ45 Plug 2 x 2
2/110 Siemens ST 80 / ST PC · 2013
2
Overview
Implementation of direct device connections over distances of
up to 100 m with Industrial Ethernet FC installation cable 2 x 2
without patching
Easy connection (insulation displacement contacts) for 4-core
Twisted Pair installation cables (100 Mbit/s) without the need
for special tools
Error-preventing connection technique thanks to visible
connection area as well as colored blade terminals
Industry-compatible design (rugged metal housing, no easily
lost small parts)
Excellent EMC shielding and deflection (metal housing)
Integrated strain-relief for installation cables
Compatible to the EN 50173 (RJ45) / ISO IEC 11801 standard
Additional strain and bending relief of plug connector possible
through latching of plug on device housing, e.g. with
SCALANCE X, SCALANCE S, ET 200S.
Ordering data Order No. Order No.
IE FC RJ45 plugs
RJ45 plug connector for Industrial
Ethernet with a rugged metal hous-
ing and integrated insulation dis-
placement contacts for connecting
Industrial Ethernet FC installation
cables
IE FC RJ45 Plug 180
180° cable outlet; for network
components and CPs/CPUs with
Industrial Ethernet interface
1 pack = 1 unit 6GK1901-1BB10-2AA0
1 pack = 10 units 6GK1901-1BB10-2AB0
1 pack = 50 units 6GK1901-1BB10-2AE0
IE FC RJ45 Plug 90
90° cable outlet; e.g. for ET 200S
1 pack = 1 unit 6GK1901-1BB20-2AA0
1 pack = 10 units 6GK1901-1BB20-2AB0
1 pack = 50 units 6GK1901-1BB20-2AE0
IE FC RJ45 Plug 145
145° cable outlet; e.g.
for SIMOTION and SINAMICS
1 pack = 1 unit 6GK1901-1BB30-0AA0
1 pack = 10 units 6GK1901-1BB30-0AB0
1 pack = 50 units 6GK1901-1BB30-0AE0
IE FC stripping tool 6GK1901-1GA00
Preadjusted stripping tool for fast
stripping of Industrial Ethernet FC
cables
IE FC TP Standard Cable GP 2 x 2
(Type A)
4-core, shielded TP installation
cable for connection to
IE FC Outlet RJ45/ IE FC RJ45 Plug;
PROFINET-compatible;
with UL approval;
Sold by the meter
max. length 1,000 m;
minimum order 20 m 6XV1840-2AH10
Preferred length
1000 m 6XV1840-2AU10
IE FC TP Flexible Cable GP 2 x 2
(Type B) 6XV1870-2B
4-core, shielded TP installation
cable for connection to
IE FC Outlet RJ45/ IE FC RJ45 Plug
for occasional movement;
PROFINET-compatible;
with UL approval;
sold by the meter; max. length
1000 m, minimum order 20 m
IE FC TP Trailing Cable GP 2 x 2
(Type C) 6XV1870-2D
4-core, shielded TP installation
cable for connection to
IE FC Outlet RJ45/ IE FC RJ45 Plug
for use in trailing cables;
PROFINET-compatible;
with UL approval;
sold by the meter; max. length
1000 m, minimum order 20 m
ST80_2013_EN_Kap02.book Seite 110 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
IE FC RJ45 Plug 2 x 2
2/111
Siemens ST 80 / ST PC · 2013
Ordering data Order No. Order No.
2
IE FC TP Trailing Cable 2 x 2
(Type C) 6XV1840-3AH10
4-core, shielded TP installation
cable for connection to
IE FC Outlet RJ45/
IE FC RJ45 Plug 180/90
for use in trailing cables;
PROFINET-compatible;
without UL approval;
sold by the meter;
max. length 1000 m,
minimum order 20 m
IE TP Torsion Cable GP 2 x 2
(Type C) 6XV1870-2F
4-core, shielded TP installation
cable for connection to
IE FC Outlet RJ45/ IE FC RJ45 Plug
for use with robots; PROFINET-
compatible; with UL approval;
sold by the meter;
max. length 1000 m,
minimum order 20 m
IE FC TP Marine Cable 2 x 2
(Type B) 6XV1840-4AH10
4-core, shielded TP installation
cable for connection to
IE FC Outlet RJ45/ IE FC RJ45
Plug 180/90; marine approval;
sold by the meter;
max. length 1000 m,
minimum order 20 m
IE FC TP FRNC Cable GP 2 x 2
(Type B) 6XV1871-2F
4-core, shielded, halogen-free TP
installation cable for connection to
IE FC Outlet RJ45/ IE FC RJ45 Plug
for occasional movement;
PROFINET-compatible;
with UL approval;
sold by the meter;
max. length 1000 m,
minimum order 20 m
IE FC TP Festoon Cable GP 2 x 2
(Type B) 6XV1871-2S
4-core, shielded TP installation
cable for connection to
IE FC Outlet RJ45/
IE FC RJ45 Plug 180/90 for use in
festoon applications;
PROFINET-compatible;
with UL approval;
sold by the meter;
max. length 1000 m,
minimum order 20 m
IE FC TP Food Cable GP 2 x 2
(Type C) 6XV1871-2L
4-core, shielded TP installation
cable for connection to
IE FC Outlet RJ45/
IE FC RJ45 Plug 180/90
for the food and beverages industry;
PROFINET-compliant;
sold by the meter;
max. length 1000 m,
minimum order 20 m
IE FC Blade Cassettes (5 mm) 6GK1901-1GB01
Replacement blade cassette for the
Industrial Ethernet stripping tool;
for use with IE FC RJ45 Plugs and
Modular Outlet,
5 items
ST80_2013_EN_Kap02.book Seite 111 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Connecting cables
2/112 Siemens ST 80 / ST PC · 2013
2
Overview
Example - connecting cables
Connecting cable DP (PROFIBUS) for Mobile Panels
Connecting cable PN (PROFINET) for Mobile Panels
Key
P = PROCESS COUPLING
K = optional process coupling (option required)
D = DOWNLOAD (update operating system, project, …)
U = booting (factory setting in the case of a missing or damaged
operating system)
MBP = Mobile Panel
You can find order numbers for the connecting cables required
to link SIMATIC Panels under ordering data.
ST80_2013_EN_Kap02.book Seite 112 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Connecting cables
2/113
Siemens ST 80 / ST PC · 2013
Overview (continued)
2
Overview of SIMATIC HMI connection options
1) Only in conjunction with the RS 422/232 converter
RS 232 external
(15/9-pole) TD-PPI
(incl. voltage) RS 232
Null modem RS 232/PPI
multi-master
cable
USB/PPI
multi-master
cable
MPI (PG-S7)
up to
187.5 kbaud
6XV1 440-2Kxxx 6ES7 901-
3EB10-0XA0 6ES7 901-
1BF00-0XA0 6ES7 901-
3CB30-0XA0 6ES7 901-
3DB30-0XA0 6ES7 901-
0BF00-0AA0
Key Panel KP8/KP8F, KP32F - - - - - -
PP7, PP17-I, PP17-II - - - - - -
KTP400 Basic mono PN - - - - - -
KTP600 Basic mono PN - - - - - -
KTP600 Basic color DP - - - D/U D/U P/D
KTP600 Basic color PN - - - - - -
KTP1000 Basic color DP - - - D/U D/U P/D
KTP1000 Basic color PN - - - - - -
KTP1500 Basic color PN - - - - - -
K(T)P400 Comfort - - - - - P/D
K(T)P700 - KP1500 Comfort - - - - - P/D
TP700 -TP2200 Comfort - - - - - P/D
MBP 177 - - - D/U - -
MBP 277 - - - D/U - -
TD200 - P - D/U - P
TD400C - P - D/U - P
OP73micro - P - D/U D/U P
TP177micro - - - D/U D/U -
OP73 - P - D/U D/U P/D
OP77A - - - D/U D/U P/D
OP77B P - D/U - - P/D
TP177A - - - D/U D/U P/D
TP177B P 1) - - D/U - P/D
TP177B 4" P 1) - D D - P/D
OP177B P 1) - - D/U - P/D
TP277-6 P 1) - - D/U - P/D
OP277-6 P 1) - - D/U - P/D
MP177-6 T P 1) - - D/U - P/D
MP277-8 T P 1) - - D/U - P/D
MP277-10 T P 1) - - D/U - P/D
MP377-12 T P 1) - - D - P/D
MP377-15 T P 1) - - D - P/D
MP377-19 T P 1) - - D - P/D
ST80_2013_EN_Kap02.book Seite 113 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Connecting cables
2/114 Siemens ST 80 / ST PC · 2013
Overview (continued)
2
Note:
This table is for basic orientation only. Technical characteristics
are described in the communication manual or the respective
user manual:
1) With gender changer
2) PROFINET IRT (Isochronous Runtime); isochronous mode only possible
with IRT-enabled switch
3) Only in conjunction with the RS422/RS232 converter
6AV6 671-8XE00-0AX0
4) WinCC flexible 2008 SP2 and higher
DP PtP DP
Standard DP
(Mobile
Panel)
PN (cross
cable) 2)
Point-to-
point
PN
(standard
cable) 2)
PN
(Mobile
Panel)
RS 422 to
RS 232
converter
RS 232 to
TTY
converter
(20 mA)
90° angular
(9-pin 1:1)
6XV1 830-
0Axxx Standard
PROFIBUS
(2-contact)
6XV1 440-
4Axxx 6XV1 870-
3RH20 Standard
Ethernet
CAT5
6XV1 440-
4Bxxx 6AV6 671-
8XE00-
0AX0
6ES5 734-
1BD20 6AV6 671-
8XD00-
0AX0
Key Panel KP8/KP8F, KP32F - - - P/D P/D - - - -
PP7, PP17-I, PP17-II P P - - - - - - -
KTP400 Basic mono PN - - - P/D/U P/D/U - - - -
KTP600 Basic mono PN - - - P/D/U P/D/U - - - -
KTP600 Basic color DP P/D P/D - - - - - - P/D/U
KTP600 Basic color PN - - - P/D/U P/D/U - - - -
KTP1000 Basic color DP P/D P/D - - - - - - P/D/U
KTP1000 Basic color PN - - - P/D/U P/D/U - - - -
KTP1500 Basic color PN - - - P/D/U P/D/U - - - -
K(T)P400 Comfort P/D P/D - P/D/U P/D/U - - - P/D/U
K(T)P700 - TP1500 Comfort P/D P/D - P/D/U P/D/U - - - P/D/U
TP700 -TP2200 Comfort P/D P/D - P/D/U P/D/U - - - P/D/U
MBP 177 DP P/D P/D P/D - - - - - -
MBP 177 PN - - - - - P/D - - -
MBP 277 P/D P/D P/D - - P/D - - -
TD200 - - - - - - - - -
TD400C - - - - - - - - -
OP73micro P - - - - - - - -
TP177micro P P - - - - - - P/D/U
OP73 P P - - - - - - -
OP77A P P - - - - - - P/D/U
OP77B P/D P/D - - - - - PP/D/U
TP177A P P - - - - - - P/D/U
TP177B DP P/D P/D - - - - PP 4) P/D/U
TP177B PN/DP P/D P/D - P/D P/D - PP 4) P/D/U
TP177B 4" P/D P/D - P/D/U P/D/U - PP 4) P/D/U
OP177B DP P/D P/D - - - - PP 4) P/D/U
OP177B PN/DP P/D P/D - P/D P/D - PP 4) P/D/U
TP277-6 P/D P/D - P/D P/D - PP 4) P/D/U
OP277-6 P/D P/D - P/D P/D - PP 4) P/D/U
MP177-6 T P/D P/D - P/D P/D - PP 4) P/D/U
MP277-8 T P/D P/D - P/D P/D - PP 4) P/D/U
MP277-8 K P/D P/D - P/D P/D - PP 4) P/D/U
MP277-10 T P/D P/D - P/D P/D - PP 4) P/D/U
MP277-10 K P/D P/D - P/D P/D - PP 4) P/D/U
MP377-12 T P/D P/D - P/D/U P/D/U - P P 4) P/D
MP377-12 K P/D P/D - P/D/U P/D/U - PP 4) P/D
MP377-15 T P/D P/D - P/D/U P/D/U - P P 4) P/D
MP377-19 T P/D P/D - P/D/U P/D/U - P P 4) P/D
ST80_2013_EN_Kap02.book Seite 114 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Connecting cables
2/115
Siemens ST 80 / ST PC · 2013
2
Ordering data Order No. Order No.
1) Instead of using longer cables, we recommend that you use additional
connection boxes, see length code in catalog appendix.
2) See length code in catalog appendix.
Note:
Cable pin assignments can be found on the Internet in the online
help of WinCC flexible and under FAQs
http://support.automation.siemens.com
This catalog only includes accessories for current products. The
complete range of accessories can be found in the Mall:
https://eb.automation.siemens.com
or on our SIMATIC Support pages:
http://support.automation.siemens.com
Connecting cables
SIMATIC S7 connecting cables
MPI cable 6ES7901-0BF00-0AA0
Between SIMATIC S7 and
programming device via MPI max.
187.5 kBaud, standard length 5.0 m
Connecting cable 6ES7901-1BF00-0XA0
Between HMI adapter and PC/TS
Adapter (RS 232 cable/null-modem
cable) for OP 77B, TP 177A/B,
OP 177B, standard length 5.0 m
Connecting cables 6XV1440-2A 2) 6XV1440-2A…
Connecting cable between
TD/TP/OP and AG S5 95U to -155U,
1000 m max.
PROFIBUS connecting cable
830-1T
For connection of data terminals,
preassembled with two sub-D con-
nectors, 9-pin terminated at both
ends
for PP, OP 73micro, OP 73,
TP 177micro, OP 77A/B, TP 177A,
TP/OP 177B
•1.5 m 6XV1830-1CH15
•3.0 m 6XV1830-1CH30
USB/PPI multi-master cable 6ES7901-3DB30-0XA0
For connecting the S7-200 to the
serial PC/OP interface
Standard length 5 m
PROFIBUS FC Standard Cable 2) 6XV1830-0E…
For connection to PPI;
standard type with special design
for quick mounting, 2-core,
shielded, sold by the meter,
max. delivery unit 1000 m,
minimum ordering quantity 20 m
Industrial Ethernet TP XP Cord
RJ45/RJ45
Crossed TP cable 4 x 2, preassem-
bled with 2 x RJ45 connectors
•1.0 m 6XV1870-3RH10
•6.0 m 6XV1870-3RH60
•10.0 m 6XV1870-3RN10
DP connecting cable
(MPI/PROFIBUS)
For wired Mobile Panels 177,
Mobile Panels 277,
standard lengths
•2 m 6XV1440-4AH20
•5 m 6XV1440-4AH50
•8 m 6XV1440-4AH80
•10 m 6XV1440-4AN10
•15 m 6XV1440-4AN15
•20 m 6XV1440-4AN20
•25 m 1) 6XV1440-4AN25
PN connecting cable (PROFINET)
For wired Mobile Panels 177,
Mobile Panels 277, standard lengths
•2 m 6XV1440-4BH20
•5 m 6XV1440-4BH50
•8 m 6XV1440-4BH80
•10 m 6XV1440-4BN10
•15 m 6XV1440-4BN15
•20 m 6XV1440-4BN20
•25 m
1) 6XV1440-4BN25
ST80_2013_EN_Kap02.book Seite 115 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Memory media
2/116 Siemens ST 80 / ST PC · 2013
2
Overview
Memory media
SIMATIC HMI memory media are suitable for industry and
optimized for the requirements in industrial environments.
Special formatting and write logarithms ensure fast read/write
cycles and a long service life of the memory cells.
Push Button Panels
Operator Panels
Touch Panels
Multi Panels
Comfort Panels
Mobile Panels
Industrial USB Hub
Technical specifications
6AV6671-1CB00-
0AX2 6AV6671-8XB10-
0AX1 6AV2181-8XP00-
0AX0 6AV6574-2AC00-
2AA1 6ES7 648-0DC50-
0AA0
SIMATIC HMI
MM memory card,
128 MB
SIMATIC HMI
SD memory card,
512 MB
SIMATIC HMI
SD memory card,
2 GB
SIMATIC HMI
CF memory card,
512 MB
SIMATIC IPC USB
FLASH DRIVE,
bootable, 8GB
Installation type/mounting
Mounting in portrait format possible Yes Yes Yes Yes Yes
Mounting in landscape format
possible Yes Yes Yes Yes Yes
Supply voltage
Type of supply voltage DC DC DC DC DC
Rated voltage/DC 3.3 V 3.3 V 3.3 V 3.3 V 5.5 V
Input current
Current consumption
(rated value) 60 mA 60 mA 60 mA 75 mA 60 mA
Memory
Type of memory Multi Media Card Secure Digital
memory card Secure Digital
memory card CompactFlash
memory CF type I USB flash drive
Size 128 Mbyte 512 Mbyte 2048Mbyte 512 Mbyte 8 192 Mbyte
Standards, approvals,
certificates
CE Yes Yes Yes Yes Yes
Ambient conditions
Operating temperature
Operating temperature range, max. 50 °C 50 °C 50 °C 50 °C 55 °C
Operating temperature range, min. C 0°C 0°C 0°C 5°C
Storage/transport temperature
•Min. -20 °C -20 °C -20 °C -20 °C -40 °C
•max. 60 °C 60 °C 60 °C 60 °C 70 °C
Relative humidity
max. relative humidity 90 % 90 % 90 % 90 % 85 %
Mechanics/material
Type of housing (front)
• Plastic Yes Yes Yes Yes Yes
ST80_2013_EN_Kap02.book Seite 116 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Memory media
2/117
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
Ordering data Order No.
Note:
For delivery units/amounts, see the technical data for the
relevant product.
This catalog only includes accessories for current products.
The complete range of accessories can be found in the Mall:
https://eb.automation.siemens.com
or on our SIMATIC Support pages:
http://support.automation.siemens.com
Dimensions
Width 24 mm 24 mm 24 mm 42.8 mm 16.7 mm
Height 32 mm 32 mm 32 mm 36.4 mm 59.1 mm
Thickness 2.1 mm 2.1 mm 2.1 mm 3.3 mm 7mm
Weight
Weight without packaging 3g 3g 3g 10 g 12 g
Scope of supply
Delivery unit in items 11111
other
Note: for OP 77B, TP177B,
OP 177B, TP 277,
OP 277, C7-635,
MP 177, MP 277,
MP 377,
Mobile Panel 177,
Mobile Panel 277,
Comfort Panel
for MP 177,
MP 277, MP 377 and
Mobile Panel 277,
WinCC flexible 2008
SP1 and higher for
OP 77, TP/OP 177,
TP/OP 277,
Mobile Panel 177,
with SD/MMC slot
For all
Comfort Panels for SIMATIC HMI
Panels and IPCs with
CF slot
for SIMATIC HMI
devices with USB slot
and SIMATIC IPC,
with installed
SIMATIC IPC BIOS
Manager
6AV6671-1CB00-
0AX2 6AV6671-8XB10-
0AX1 6AV2181-8XP00-
0AX0 6AV6574-2AC00-
2AA1 6ES7 648-0DC50-
0AA0
SIMATIC HMI
MM memory card,
128 MB
SIMATIC HMI
SD memory card,
512 MB
SIMATIC HMI
SD memory card,
2 GB
SIMATIC HMI
CF memory card,
512 MB
SIMATIC IPC USB
FLASH DRIVE,
bootable, 8GB
SIMATIC HMI MM memory card
128 MB 6AV6671-1CB00-0AX2
For contents and matching devices,
see Technical Data in the Mall
SIMATIC HMI SD memory card
512 MB 6AV6671-8XB10-0AX1
For contents and matching devices,
see Technical Data in the Mall
SIMATIC HMI SD memory card
2GB 6AV2181-8XP00-0AX0
For contents and matching devices,
see Technical Data in the Mall
SIMATIC HMI CF memory card
512 MB 6AV6574-2AC00-2AA1
For contents and matching devices,
see Technical Data in the Mall
PC card adapter
for CF memory card 6AV6574-2AF00-8AX0
For contents and matching devices,
see Technical Data in the Mall
PC memory card, 512 MB 6AV6574-2AC00-2AF1
For contents and matching devices,
see Technical Data in the Mall
SIMATIC IPC USB flash drive 8 GB 6ES7648-0DC50-0AA0
For contents and matching devices,
see Technical Data in the Mall
SIMATIC memory module for
Push Button Panel 6ED1056-1BA00-0AA0
For contents and matching devices,
see Technical Data in the Mall
ST80_2013_EN_Kap02.book Seite 117 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Service sets
2/118 Siemens ST 80 / ST PC · 2013
2
Overview
Service sets are available for the product groups listed below:
Push Button Panels
Key Panels
Operator Panels
Touch Panels
Multi Panels
Basic Panels
Comfort Panels
Mobile Panels
Industrial USB Hub
Technical specifications
6AV6671-2EA00-
0AX0 6AV6675-3AA00-
0AX0 6AV6671-4CA00-
0AX0 6AV6574-1AA04-
4AA0 6AV6671-5CA00-
0AX2 6AV6671-3EA01-
0AX0
Service set 4"
and 6" devices Service set 10"
devices, Type 2 Service set 15"
devices Service set
Mobile Panel Service set
Mobile Panel
277(F)
IWLAN V2
Service set
Industrial USB
Hub 4
Battery
Design
Special design Yes;
Spare 3.6 V
1.5 Ah backup
battery included
in the package
Standards, approvals, certificates
CE Yes Yes Yes Yes Yes Yes
Ambient conditions
Operating temperature
Operating temperature range, max. 55 °C 55 °C 55 °C 55 °C 55 °C 55 °C
Operating temperature range, min. C 0°C C C 0°C C
Storage/transport temperature
•Min. -20 °C -20 °C -20 °C -20 °C -20 °C -20 °C
•max. 70 °C 70 °C 70 °C 70 °C 70 °C 70 °C
Relative humidity
max. relative humidity 95 % 95 % 95 % 95 % 95 % 95 %
ST80_2013_EN_Kap02.book Seite 118 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Service sets
2/119
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
Scope of supply
Number of sets 1; Content: 2 x
seal KTP 400-TP
177B 4", 2 x seal
for KTP 600, 7 x
aluminum mount-
ing clip, 1 x 2-pin
female connector
1; Content:
1 x mounting
seal, 10 x cast
aluminum mount-
ing clip, 1 x 2-pin
female connector
1; Content:
1 x mounting
seal, 1 x memory
card lock,
12 x cast alumi-
num mounting
clip, 1 x 2-pin
female connector,
1 x Allen key
1; Content:
1 x blanking plug,
2 x PG cable
gland A-Box,
2 x 12-pole termi-
nal box,
1 x 3-pole termi-
nal box,
1 x blanking
cover A-Box,
2 x corner seal l/r
and O-ring, 4 x
decorative film for
corner seal l/r
1; Content:
2 x charging sta-
tion cover l/r,
1 x charging sta-
tion connector,
2 x corner seal l/r,
2 x gasket cor-
ner seal, 4 x
decorative film
corner seal l/r,
1 x battery incl.
cover, 1 x spare
key
1; Content:
1 x mounting
seal, 1 x mount-
ing frame, 5 x
plastic mounting
clip, 1 x 2-pin
female connector
other
Note: for KTP 400
Basic, KTP 600
Basic, TP 177B 4"
for MP 277 10"
Touch with stain-
less steel front
for MP 377 15"
Touch with stain-
less steel front
for Mobile Panel
170, Mobile Panel
177
for Mobile Panel
277 IWLAN V2,
Mobile Panel
277F IWLAN V2
For the Industrial
USB Hub 4
6AV3678-3XC30 6AV3678-1CC10 6AV6671-1XA00-
0AX0 6AV6574-1AA00-
4AX0 6AV2181-8XA80-
0AX0 6AV6671-2XA00-
0AX0
Service set
Push Button
Panel
Service set
TD17, OP7/17 Service set
OP73micro,
OP73, OP77
Service set 6"
devices, Type 1 Service set 6"
devices, Type 2 Service set 6"
devices, Type 3
Standards, approvals, certificates
CE Yes Yes Yes Yes Yes Yes
Ambient conditions
Operating temperature
Operating temperature range, max. 55 °C 55 °C 55 °C 55 °C 55 °C 55 °C
Operating temperature range, min. C 0°C C C 0°C C
Storage/transport temperature
•Min. -20 °C -20 °C -20 °C -20 °C -20 °C -20 °C
•max. 70 °C 70 °C 70 °C 70 °C 70 °C 70 °C
Relative humidity
max. relative humidity 95 % 95 % 95 % 95 % 95 % 95 %
Scope of supply
Number of sets 1; Content:
1 x mounting seal
PP7, 1 x mount-
ing seal PP17, 5
x plastic mount-
ing clip, 1 x 2-pin
female connector,
1 x 3-pin female
connector, 1 x
4-pin female con-
nector, 2 x 16-pin
female connector
1; Content:
1 x mounting seal
TD17, 1 x mount-
ing seal OP7,
1 x mounting seal
TD/OP17,
5 x plastic
mounting clip
1; Content:
1 x mounting seal
OP73, 1 x mount-
ing seal OP77,
4 x plastic mount-
ing clip, 1 x 2-pin
female connector
1; Content:
3 x mounting
seal, 2 x labeling
strip, 7 x plastic
mounting clip,
1 x 2-pin female
connector
1; Content:
3 x mounting
seal, 2 x labeling
strip, 7 x plastic
mounting clip,
20 x aluminum
mounting clip,
1 x 2-pin female
connector
1; Content:
1 x mounting seal
TP 177, 1 x
mounting seal
OP 177, 7 x plas-
tic mounting clip,
1 x 2-pin female
connector
other
Note: for PP7, PP17-I,
PP17-II for TD17, OP7,
OP17 for OP73micro,
OP73, OP77A,
OP77B
for TP 070, TP
170A/B, OP
170B, TP
170micro, OP
270 6", TP 270 6",
MP 270B 6"
Touch
for TP 070, TP
170A/B, OP
170B, TP
170micro, OP /TP
270 6", MP 177
6"T, MP 270B 6"
Touch
for TP 177micro,
TP 177A, TP
177B, OP 177B
6AV6671-2EA00-
0AX0 6AV6675-3AA00-
0AX0 6AV6671-4CA00-
0AX0 6AV6574-1AA04-
4AA0 6AV6671-5CA00-
0AX2 6AV6671-3EA01-
0AX0
Service set 4"
and 6" devices Service set 10"
devices, Type 2 Service set 15"
devices Service set
Mobile Panel Service set
Mobile Panel
277(F)
IWLAN V2
Service set
Industrial USB
Hub 4
ST80_2013_EN_Kap02.book Seite 119 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Service sets
2/120 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
6AV6574-
1AA00-2CX0 6AV6574-
1AA00-2DX0 6AV6671-
3XA01-0AX0 6AV6671-
3XA01-0AX1 6AV6574-
1AA00-2BX0 6AV6671-
4XA00-0AX0 6AV6671-
5CA00-0AX1
Service set
10" to 15"
devices
Service set
10" devices,
Type 1
Service set
6" to 10"
devices
Service set
8" to 10"
devices
Service set
12" devices Service set
12" to 19"
devices
Service set
Mobile Panel
277 (F)
IWLAN V1
Battery
Design
Special design Yes; Spare
battery
included in the
package
Standards, approvals, certificates
CE Yes Yes Yes Yes Yes Yes Yes
Ambient conditions
Operating temperature
Operating temperature range, max. 55 °C 55 °C 55 °C 55 °C 55 °C 55 °C 55 °C
Operating temperature range, min. C C 0°C 0°C C C 0°C
Storage/transport temperature
•Min. -20 °C -20 °C -20 °C -20 °C -20 °C -20 °C -20 °C
•max. 70 °C 70 °C 70 °C 70 °C 70 °C 70 °C 70 °C
Relative humidity
max. relative humidity 95 % 95 % 95 % 95 % 95 % 95 % 95 %
Scope of supply
Number of sets 1; Content:
2 x mounting
seal,
7 x mounting
clip, 1 x 2-pin
female con-
nector,
1 x CF card
lock, 1 x
PC card lock
1; Content:
1 x slide-in
labels OP 270
10" and MP
270 10" Key,
1 x mounting
seal OP 270
10" and MP
270 10" Key,
10 x cast alu-
minum mount-
ing clip, 1 x
2-pin female
connector
1; Content:
6 x device-
specific seal,
15 x alumi-
num mounting
clip, 1 x 2-pin
female con-
nector
1; Content:
14 x spring
mounting clip,
1 x connector,
female, 2-pin
1; Content:
2 x labeling
strip, 6 x alu-
minum mount-
ing clip, 1 x
2-pin female
connector,
2 x memory
card lock
1; Content:
1 x mounting
seal MP 377
12" Key, 1 x
mounting seal
MP 377 12"
Touch, 1 x
mounting seal
MP 377 15"
Touch, 1 x
mounting seal
MP 377 19"
Touch, 18 x
aluminum
mounting clip,
1 x 2-pin
female con-
nector
1; Content:
2 x charging
station cover
l/r, 1 x charg-
ing station
connector, 2 x
corner seal l/r,
2 x gasket cor-
ner seal, 4 x
decorative film
corner seal l/r,
1 x battery
incl. cover, 1 x
spare key
other
Note: for C7-636
Touch, TP270
10", MP270B
10" Touch,
MP370 12"
Touch, MP370
15" Touch
for OP 270 10",
MP 270B Key for TP/OP 277
6", MP 277 8"
Touch, MP 277
8" Key, MP 277
10" Key prod-
uct version "ES
14" and later,
MP 277 10"
Touch product
version "ES 14"
and later
for MP 277 8"
Touch, MP 277
8" Key prod-
uct version "ES
15" and later,
MP 277 10"
Touch product
version "ES 15"
and later
for MP 370 12"
Key for MP 377 12"
Key, MP 377
12" Touch,
MP 377 15"
Touch, MP 377
19" Touch
for Mobile
Panel 277
IWLAN, Mobile
Panel 277F
IWLAN
ST80_2013_EN_Kap02.book Seite 120 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Service sets
2/121
Siemens ST 80 / ST PC · 2013
2
Ordering data Order No. Order No.
Note:
This catalog only includes accessories for current products.
The complete range of accessories can be found in the Mall:
https://eb.automation.siemens.com
or on our SIMATIC Support pages:
http://support.automation.siemens.com
Service set for 4" and 6" devices 6AV6671-2EA00-0AX0
For contents and matching devices,
see Technical Data
Service set for 10" devices, Type 2 6AV6675-3AA00-0AX0
For contents and matching devices,
see Technical Data
Service set for 15" devices 6AV6671-4CA00-0AX0
For contents and matching devices,
see Technical Data
Service set for Mobile Panel 6AV6574-1AA04-4AA0
For contents and matching devices,
see Technical Data
Service set for Mobile Panel
277(F) IWLAN 6AV6671-5CA00-0AX2
For contents and matching devices,
see Technical Data
Service Kit Industrial USB Hub 4 6AV6671-3EA01-0AX0
For contents and matching devices,
see Technical Data
Service set for pushbutton panel 6AV3678-3XC30
For contents and matching devices,
see Technical Data in the Mall
Service set for TD17, OP7/17 6AV3678-1CC10
For contents and matching devices,
see Technical Data in the Mall
Service set for OP73 micro, OP73,
OP77 6AV6671-1XA00-0AX0
For contents and matching devices,
see Technical Data in the Mall
Service set for 6" devices, Type 1 6AV6574-1AA00-4AX0
For contents and matching devices,
see Technical Data in the Mall
Service set for 6" devices, Type 2 6AV2181-8XA80-0AX0
For contents and matching devices,
see Technical Data in the Mall
Service set for 6" devices, Type 3 6AV6671-2XA00-0AX0
For contents and matching devices,
see Technical Data in the Mall
Service set for 10" to 15" devices 6AV6574-1AA00-2CX0
For contents and matching devices,
see Technical Data in the Mall
Service set for 10", Type 1 6AV6574-1AA00-2DX0
For contents and matching devices,
see Technical Data in the Mall
Service set for 6" to 10" devices 6AV6671-3XA01-0AX0
For contents and matching devices,
see Technical Data in the Mall
Service set for 8" to 10" devices 6AV6671-3XA01-0AX1
For contents and matching devices,
see Technical Data in the Mall
Service set for 12" devices 6AV6574-1AA00-2BX0
For contents and matching devices,
see Technical Data in the Mall
Service set for 12" to 19" devices 6AV6671-4XA00-0AX0
For contents and matching devices,
see Technical Data in the Mall
Service set for Mobile Panel
277(F) IWLAN V1 6AV6671-5CA00-0AX1
For contents and matching devices,
see Technical Data in the Mall
ST80_2013_EN_Kap02.book Seite 121 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Protective covers
2/122 Siemens ST 80 / ST PC · 2013
2
Overview
Protective covers with IP65 degree of protection provide
complete frontal protection of the panel against dirt and
scratches; the protective covers can be kept clean using high-
pressure cleaning equipment. Ready-made templates can be
downloaded to help you create and print out your own low-cost
frame designs between panel and protective cover.
Adhesive protective membranes are available for simple display
protection.
Protective covers are available for the following
SIMATIC HMI Panels:
Touch Panels
Operator Panels
Multi Panels
Technical specifications
6AV6574-1AE00-
4AX0 6AV6671-1AJ00-
0AX0 6AV6671-2DJ00-
0AX0 6AV6671-3CK01-
0AX0 6AV6671-3CK00-
0AX0
Protective cover 6"
Touch devices Protective cover
OP77 Protective cover
OP177 Protective cover
MP 277 8" Touch Protective cover
MP 277 10" Touch
Installation type/mounting
Mounting in portrait format possible Yes Yes Yes Yes Yes
Mounting in landscape format
possible Yes Yes Yes Yes Yes
Degree and class of protection
IP (at the front) IP65 IP65 IP65 IP65 IP65
Standards, approvals, certificates
CE Yes Yes Yes Yes Yes
Ambient conditions
Operating temperature
Operating temperature range, max. 50 °C 50 °C 50 °C 50 °C 50 °C
Operating temperature range, min. C 0°C 0°C 0°C 0°C
Storage/transport temperature
•Min. -20 °C -20 °C -20 °C -20 °C -20 °C
•max. 60 °C 60 °C 60 °C 60 °C 60 °C
Relative humidity
max. relative humidity 95 % 95 % 95 % 95 % 95 %
Mechanics/material
Plastic Yes Yes Yes Yes Yes
Dimensions
Width 242.3 mm 178.6 mm 274.3 mm 270.8 mm 355.8 mm
Height 186.3 mm 214.6 mm 243.26 mm 211 mm 294 mm
Thickness 10 mm 7.8 mm 7.8 mm 7.8 mm 7.8 mm
Height of housing front
Mounting cutout, width 198 mm 135 mm 229 mm 226 mm 310 mm
Mounting cutout, height 142 mm 171 mm 196 mm 166 mm 248 mm
Weight
Weight without packaging 750 g 750 g 750 g 750 g 750 g
ST80_2013_EN_Kap02.book Seite 122 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Protective covers
2/123
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
Ordering data Order No.
1) E14 = Product version 14
2) E03 = Product version 03
Note:
This catalog only includes accessories for current products.
The complete range of accessories can be found in the Mall:
https://eb.automation.siemens.com
or on our SIMATIC Support pages:
http://support.automation.siemens.com
Scope of supply
Number of sets 2; 2 cover frames,
2 base frames,
2 protective covers,
molded (for TP 070,
TP 170micro,
TP 170A/B), 2 protec-
tive covers, smooth
(for TP 177micro,
TP 177A/B, TP 270 6",
MP 177 6" Touch,
MP 270 6" Touch)
2; 2 cover frames,
2 base frames,
2 protective covers
2; 2 cover frames,
2 base frames,
2 protective covers
2; 2 cover frames,
2 base frames,
2 protective covers
2; 2 cover frames,
2 base frames,
2 protective covers
other
Note: for TP 070,
TP 170A, TP 170B,
TP 170micro,
TP 177micro,
TP 177A, TP 177B,
TP 270 6 ", TP 277 6 ",
MP 270 6" Touch
for OP 77A, OP 77B For OP177B for MP 277 8" Touch
as far as product
version "ES 14" with
narrow frame
for MP 277 10" Touch
up to product version
"ES 14 ", Thin Client
10" up to "ES 03"
(6AV6646-0AA21-
2AX0) with narrow
frame
6AV6574-1AE00-
4AX0 6AV6671-1AJ00-
0AX0 6AV6671-2DJ00-
0AX0 6AV6671-3CK01-
0AX0 6AV6671-3CK00-
0AX0
Protective cover 6"
Touch devices Protective cover
OP77 Protective cover
OP177 Protective cover
MP 277 8" Touch Protective cover
MP 277 10" Touch
Protective covers
for 6" Touch devices 6AV6574-1AE00-4AX0
For TP 070, TP 170micro,
TP 177micro, TP 170A/B,
TP 177A/B, TP 270 6", TP 277 6",
MP 177 6" Touch, MP 270 6" Touch
consisting of: see technical data
Protective covers for OP 77 6AV6671-1AJ00-0AX0
For OP77 and OP77B
consisting of: see technical data
Protective covers for OP 177 6AV6671-2DJ00-0AX0
For OP177B
consisting of: see technical data
Protective covers for MP 277 8"
Touch devices 6AV6671-3CK01-0AX0
Only suitable for MP 277 8" Touch
up to E14 1) (for devices with a
narrow frame geometry)
consisting of: see technical data
Protective covers for MP 277 10"
Touch devices 6AV6671-3CK00-0AX0
Only suitable for
MP 277 10" Touch up to E14 1)
and 10" Thin Client up to E03 2)
(for devices with a narrow frame
geometry)
consisting of: see technical data
ST80_2013_EN_Kap02.book Seite 123 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Protective films
2/124 Siemens ST 80 / ST PC · 2013
2
Overview
Protective films for:
Touch Panels
C7 devices
Multi Panels
Thin Clients
Touch Panels
Basic Panels
Comfort Panels
Mobile Panels
Protective films protect the display from dirt and scratching
during operation and use.
For complete protection of the front side in harsh environments,
protective covers are available for some devices.
Note:
During installation, the protective films must completely cover
the display. For compatibility reasons, not all protective films
extend as far as the edge of the enclosure. This does not,
however, affect the protective function.
ST80_2013_EN_Kap02.book Seite 124 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Protective films
2/125
Siemens ST 80 / ST PC · 2013
2
Technical specifications
6AV6671-2EC00-
0AX0 6AV6671-2XC00-
0AX0 6AV6574-1AD04-
4AA0 6AV6671-5BC00-
0AX0 6AV6645-7AB15-
0AS0 6AV6671-3DC00-
0AX0
Protective film
4" Touch
devices
Protective film
6" Touch
devices, Type 3
Protective film
6" Touch
devices,
Type 10
Protective film
8" Touch
devices,
Type 10
Protective film
10" Touch
devices,
Type 10
Protective film
10" Thin Client
and MP277 up to
ES14
Installation type/mounting
Mounting in portrait format possible Yes Yes Yes Yes Yes Yes
Mounting in landscape format possi-
ble Yes Yes Yes Yes Yes Yes
Standards, approvals, certificates
CE Yes Yes Yes Yes Yes Yes
Ambient conditions
Operating temperature
Operating temperature range, max. 50 °C 50 °C 50 °C 50 °C 50 °C 50 °C
Operating temperature range, min. C 0°C C C 0°C C
Storage/transport temperature
•Min. -20 °C -20 °C -20 °C -20 °C -20 °C -20 °C
•max. 60 °C 60 °C 60 °C 60 °C 60 °C 60 °C
Relative humidity
max. relative humidity 90 % 90 % 90 % 90 % 90 % 90 %
Films
printable with laser printer Yes Yes Yes Yes Yes Yes
Mechanics/material
Plastic Yes;
Nonreflecting Yes;
Nonreflecting Yes;
Nonreflecting Yes;
Nonreflecting Yes; Nonreflect-
ing Yes;
Nonreflecting
Dimensions
Width 120 mm 179.4 mm 120.5 mm 155.5 mm 223.17 mm 292 mm
Height 105 mm 141.4 mm 91 mm 124.9 mm 170.37 mm 248 mm
Thickness 0.125 mm 0.125 mm 0.125 mm 0.3 mm 0.3 mm 0.125 mm
Scope of supply
Delivery unit in items 10 10 10 210 10
other
Note: for TP 177B 4",
KTP 400 Basic for TP 177micro,
TP 177A,
TP 177B,
OP 177B,
KTP 600 Basic
for
Mobile Panel 170,
Mobile Panel 177
for
Mobile Panel 277
8"
for
Mobile Panel 277
10"
ST80_2013_EN_Kap02.book Seite 125 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Protective films
2/126 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
6AV6671-3DC00-
0AX5 6AV6574-1AD00-
4EX0 6AV2124-6DJ00-
0AX0 6AV2124-6GJ00-
0AX0 6AV2124-6JJ00-
0AX0 6AV2124-6MJ00-
0AX0
Protective film
10" Key Panel,
Thin Client and
MP277 as of
ES15
Protective film
15" TP1500,
MP370/377 and
ThinClient
Protective film
4" widescreen Protective film
7" widescreen Protective film
9" widescreen Protective film
12" widescreen
Installation type/mounting
Mounting in portrait format possible Yes Yes Yes Yes Yes Yes
Mounting in landscape format
possible Yes Yes Yes Yes Yes Yes
Standards, approvals, certificates
CE Yes Yes Yes Yes Yes Yes
Ambient conditions
Operating temperature
Operating temperature range, max. 50 °C 50 °C 50 °C 50 °C 50 °C 50 °C
Operating temperature range, min. C 0°C C C 0°C C
Storage/transport temperature
•Min. -20 °C -20 °C -20 °C -20 °C -20 °C -20 °C
•max. 60 °C 60 °C 60 °C 60 °C 60 °C 60 °C
Relative humidity
max. relative humidity 90 % 90 % 90 % 90 % 90 % 90 %
Films
printable with laser printer Yes Yes Yes Yes Yes Yes
Mechanics/material
Plastic Yes;
Nonreflecting Yes;
Nonreflecting Yes;
Nonreflecting Yes;
Nonreflecting Yes;
Nonreflecting Yes;
Nonreflecting
Dimensions
Width 299.8 mm 362 mm 131.4 mm 205.4 mm 265.4 mm 321.4 mm
Height 259.9 mm 289 mm 107.4 mm 149.4 mm 181.4 mm 232.4 mm
Thickness 0.125 mm 0.125 mm 0.125 mm 0.125 mm 0.125 mm 0.125 mm
Scope of supply
Delivery unit in items 10 10 10 10 10 10
other
Note: for KTP400
Comfort, KTP400
Basic color PN
for TP700
Comfort,
IPC277D
for TP900
Comfort,
IPC277D
for TP1200
Comfort,
IPC277D
ST80_2013_EN_Kap02.book Seite 126 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Protective films
2/127
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
6AV2124-6QJ00-0AX1 6AV2124-6UJ00-0AX1 6AV2124-6XJ00-0AX1
Protective film 15" widescreen Protective film 19" widescreen Protective film 22" widescreen
Installation type/mounting
Mounting in portrait format possible Yes Yes Yes
Mounting in landscape format
possible Yes Yes Yes
Standards, approvals, certificates
CE Yes Yes Yes
Ambient conditions
Operating temperature
Operating temperature range, max. 50 °C 50 °C 50 °C
Operating temperature range, min. C C C
Storage/transport temperature
•Min. -20 °C -20 °C -20 °C
•max. 60 °C 60 °C 60 °C
Relative humidity
max. relative humidity 90 % 90 % 90 %
Films
printable with laser printer Yes Yes Yes
Mechanics/material
Plastic Yes; Nonreflecting Yes; Nonreflecting Yes; Nonreflecting
Dimensions
Width 368 mm 451 mm 518 mm
Height 231 mm 285 mm 334 mm
Thickness 0.125 mm 0.125 mm 0.125 mm
Weight
Weight without packaging 26 g; Per unit 34 g; Per unit 44 g; Per unit
Scope of supply
Delivery unit in items 10 10 10
other
Note: for Comfort Panel, IPC, Flat Panel,
Thin Client for Comfort Panel, IPC, Flat Panel,
Thin Client for Comfort Panel, IPC, Flat Panel,
Thin Client
ST80_2013_EN_Kap02.book Seite 127 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Protective films
2/128 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
6AV6574-1AD00-
4DX0 6AV6574-1AD00-
4CX0 6AV6671-2XC00-
0AX0 6AV6671-3CC00-
0AX0 6AV6671-3CC00-
0AX5 6AV7672-1CE00-
0AA0
Protective film
6" Touch
devices, Type 2
Protective film
10" - 12" TP/MP
270/370/377 and
C7-636
Protective film
6" Touch
devices, Type 3
Protective film
8" Touch
devices, Type 1
Protective film
8" Touch
devices, Type 2
Protective film
19" MP377,
panel PC and
Flat Panel
Installation type/mounting
Mounting in portrait format possible Yes Yes Yes Yes Yes Yes
Mounting in landscape format
possible Yes Yes Yes Yes Yes Yes
Standards, approvals, certificates
CE Yes Yes Yes Yes Yes Yes
Ambient conditions
Operating temperature
Operating temperature range, max. 50 °C 50 °C 50 °C 50 °C 50 °C 50 °C
Operating temperature range, min. C 0°C C C 0°C C
Storage/transport temperature
•Min. -20 °C -20 °C -20 °C -20 °C -20 °C -20 °C
•max. 60 °C 60 °C 60 °C 60 °C 60 °C 60 °C
Relative humidity
max. relative humidity 90 % 90 % 90 % 90 % 90 % 90 %
Films
printable with laser printer Yes Yes Yes Yes Yes Yes
Mechanics/material
Plastic Yes;
Nonreflecting Yes;
Nonreflecting Yes;
Nonreflecting Yes;
Nonreflecting Yes;
Nonreflecting Yes;
Nonreflecting
Dimensions
Width 178.4 mm 297.4 mm 179.4 mm 207 mm 217 mm 378 mm
Height 135.4 mm 254.4 mm 141.4 mm 165 mm 217 mm 302.5 mm
Thickness 0.125 mm 0.125 mm 0.125 mm 0.125 mm 0.125 mm 0.2 mm
Scope of supply
Delivery unit in items 10 10 10 10 10 10
other
Note: for TP 270 6",
TP 277 6",
MP 177 6" Touch,
MP 270B 6"
Touch
for TP 177micro,
TP 177A,
TP 177B,
OP 177B,
KTP 600 Basic
for MP 277 8"
Touch up to
product version
"ES 14"
for MP 277 8"
Touch in product
version "ES 15"
and later
ST80_2013_EN_Kap02.book Seite 128 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Protective films
2/129
Siemens ST 80 / ST PC · 2013
2
Ordering data Order No. Order No.
Note:
This catalog only includes accessories for current products. The
complete range of accessories can be found in the Mall:
https://eb.automation.siemens.com
or on our SIMATIC Support pages:
http://support.automation.siemens.com
Protective films for 4" Touch
devices 6AV6671-2EC00-0AX0
For contents and matching devices,
see Technical Data and Mall
Protective films for 6" Touch
devices, type 4 6AV6671-2XC00-0AX0
For contents and matching devices,
see Technical Data and Mall
Protective films for 6" Touch
devices, type 10 6AV6574-1AD04-4AA0
For contents and matching devices,
see Technical Data and Mall
Protective films for 8" Touch
devices, type 10 6AV6671-5BC00-0AX0
For contents and matching devices,
see Technical Data and Mall
Protective films for 10" Touch
devices, type 10 6AV6645-7AB15-0AS0
For contents and matching devices,
see Technical Data and Mall
Protective films for 10" Touch
devices, type 1 6AV6671-3DC00-0AX0
For contents and matching devices,
see Technical Data and Mall
Protective films for 10" Touch
devices, type 2 6AV6671-3DC00-0AX5
For contents and matching devices,
see Technical Data and Mall
Protective films for 15" Touch
devices 6AV6574-1AD00-4EX0
For contents and matching devices,
see Technical Data and Mall
Protective films 4" widescreen 6AV2124-6DJ00-0AX0
For contents and matching devices,
see Technical Data and Mall
Protective films 7" widescreen 6AV2124-6GJ00-0AX0
For contents and matching devices,
see Technical Data and Mall
Protective films 9" widescreen 6AV2124-6JJ00-0AX0
For contents and matching devices,
see Technical Data and Mall
Protective films 12" widescreen 6AV2124-6MJ00-0AX0
For contents and matching devices,
see Technical Data and Mall
Protective films 15" widescreen 6AV2124-6QJ00-0AX1
For contents and matching devices,
see Technical Data and Mall
Protective films 19" widescreen 6AV2124-6UJ00-0AX1
For contents and matching devices,
see Technical Data and Mall
Protective films 22" widescreen 6AV2124-6XJ00-0AX1
For contents and matching devices,
see Technical Data and Mall
Protective films for 6" Touch
devices, type 1 6AV6574-1AD00-4AX0
For contents and matching devices,
see Technical Data and Mall
Protective films for 6" Touch
devices, type 4 6AV3672-2CS00
For contents and matching devices,
see Technical Data and Mall
Protective films for 10" Touch
devices, type 3 6AV3672-2CS11
For contents and matching devices,
see Technical Data and Mall
Protective films for 10" Touch
devices, type 2 6AV6574-1AD00-4DX0
For contents and matching devices,
see Technical Data and Mall
Protective films for 10" to 12"
Touch devices 6AV6574-1AD00-4CX0
For contents and matching devices,
see Technical Data and Mall
Protective films for 6" Touch
devices, type 3 6AV6671-2XC00-0AX0
For contents and matching devices,
see Technical Data and Mall
Protective films for 8" Touch
devices, type 1 6AV6671-3CC00-0AX0
For contents and matching devices,
see Technical Data and Mall
Protective films for 8" Touch
devices, type 2 6AV6671-3CC00-0AX5
For contents and matching devices,
see Technical Data and Mall
Protective films for 19" Touch
devices 6AV7672-1CE00-0AA0
For contents and matching devices,
see Technical Data and Mall
ST80_2013_EN_Kap02.book Seite 129 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Fasteners
2/130 Siemens ST 80 / ST PC · 2013
2
Overview
All parts required to install a SIMATIC HMI Panel are listed here.
Mounting frames enable compliance with device-specific
degrees of protection IP65, NEMA4x and NEMA12 (indoor only)
if the thickness of the mounting plate is less than the minimum
plate thickness specified in the operating instructions. The
mounting frame has been specially developed for plate thick-
nesses of less than 2 mm.
Depending on the device, different mounting clips are available
for attaching the panel.
Memory card locks (snappable and slideable) are also available
to secure memory cards in the SIMATIC HMI Comfort Panels.
Push Button Panel
Key Panel
Text Display
Operator Panel
Touch Panel
Multi Panel
Basic Panel
Comfort Panel
Note regarding Industrial USB Hub 4:
The mounting frame is only available in the service pack
6AV6671-3EA01-0AX0.
Technical specifications
6AV6671-3CS00-0AX0 6AV6671-3CS01-0AX0 6AV6671-8XS00-0AX0
Mounting frame 8" Touch Mounting frame 8" Key Mounting frame 10" to 12"
Touch devices
Installation type/mounting
Mounting in portrait format possible Yes Yes Yes
Mounting in landscape format possible Yes Yes Yes
Standards, approvals, certificates
CE Yes Yes Yes
Ambient conditions
Operating temperature
Operating temperature range, max. 55 °C 55 °C 55 °C
Operating temperature range, min. C C C
Storage/transport temperature
•Min. -20 °C -20 °C -20 °C
•max. 70 °C 70 °C 70 °C
Relative humidity
max. relative humidity 90 % 90 % 90 %
Mechanics/material
Type of housing (front)
Sheet steel Yes Yes Yes
Scope of supply
Delivery unit in items 1 1 1
other
Note: For MP 277 8" Touch For MP 277 8" Key For KTP1000 Basic, MP 277 10"
Touch, MP 377 12" Touch,
Thin Client 10"
ST80_2013_EN_Kap02.book Seite 130 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Fasteners
2/131
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
6AV6671-8XK00-0AX2 6AV6671-8XK00-0AX1 6AV6671-8XK00-0AX0
Mounting clip, plastic Mounting clip, spring Mounting clip, aluminum
Installation type/mounting
Mounting in portrait format possible Yes Yes Yes
Mounting in landscape format possible Yes Yes Yes
Standards, approvals, certificates
CE Yes Yes Yes
Ambient conditions
Operating temperature
Operating temperature range, max. 55 °C 55 °C 55 °C
Operating temperature range, min. C C C
Storage/transport temperature
•Min. -20 °C -20 °C -20 °C
•max. 70 °C 70 °C 70 °C
Relative humidity
max. relative humidity 90 % 90 % 90 %
Mechanics/material
Screw type
•4.5 V Yes; Original partially Phillips screw Yes
Type of housing (front)
• Plastic Yes Yes
•Aluminum Yes
Dimensions
Width 30 mm 20 mm 15 mm
Height 17 mm; Without screw 35 mm 21 mm; Without screw
Thickness 8mm 20 mm 15 mm
Weight
Weight without packaging 4 g; Per unit 8g; Per unit 5g; Per unit
Scope of supply
Delivery unit in items 20 20 20
other
Note: TD17, OP7/17/73, OP77A/B,
TP/OP170, KP300 mono,
KTP400 color, TP/OP177 except
TP177 4", MP270-6T, TP/OP270-6"
TP177-4", TP/OP 277-6", MP177-6,
MP277-10" T, MP277-8", MP277-8"T,
MP277-10"K, MP377 12-19", TC 10",
TC 15", KTP400 Basic mono,
KTP600, KTP1000, KTP1500,
KP700 Comfort, TP700 Comfort,
KP900 Comfort, TP900 Comfort,
KP1200 Comfort, TP1200 Comfort
and IPC 277D 7, 9, 12"
TP177-4", TP/OP 277-6", MP177-6,
MP277-10" T, MP277-8", MP277-8"T,
MP277-10"K, MP377 12-19", TC 10",
TC 15", KTP400 Basic mono,
KTP600, KTP1000, KTP1500,
KP700 Comfort, TP700 Comfort,
KP900 Comfort, TP900 Comfort,
KP1200 Comfort, TP1200 Comfort
and IPC 277D 7, 9, 12"
ST80_2013_EN_Kap02.book Seite 131 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Fasteners
2/132 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
6AV6671-8XK00-0AX3 6AV6671-8XK00-0AX4
Mounting clip, steel Mounting bracket, steel
Installation type/mounting
Mounting in portrait format possible Yes Yes
Mounting in landscape format possible Yes Yes
Standards, approvals, certificates
CE Yes Yes
Ambient conditions
Operating temperature
Operating temperature range, max. 55 °C 55 °C
Operating temperature range, min. C C
Storage/transport temperature
•Min. -20 °C -20 °C
•max. 70 °C 70 °C
Relative humidity
max. relative humidity 90 % 90 %
Mechanics/material
Screw type
•4.5 V Yes Yes
Type of housing (front)
Sheet steel Yes Yes
Dimensions
Width 20 mm 142 mm
Height 15 mm; Without screw 18 mm; Without screw
Thickness 8mm 8mm
Scope of supply
Delivery unit in items 20 10
other
Note: 15", 19" and 22" widescreen - Comfort Panels, IPCs, Flat
Panels and Thin Clients. Plate thicknesses up to 6 mm 15", 19" and 22" widescreen - Comfort Panels, IPCs, Flat
Panels and Thin Clients, except SCD1900 19" wide-
screen. Plate thicknesses up to 6 mm
ST80_2013_EN_Kap02.book Seite 132 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Fasteners
2/133
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
6AV2181-4DM10-0AX0 6AV2181-4XM00-0AX0
Memory card lock 4" Memory card lock 7" - 22"
Installation type/mounting
Wall mounting/direct mounting possible Yes; Snap-on Yes; Snap-on
Degree and class of protection
IP (at the front) 20 20
Standards, approvals, certificates
CE Yes Yes
Ambient conditions
Operating temperature
Operating temperature range, max. 55 °C 55 °C
Operating temperature range, min. C C
Storage/transport temperature
•Min. -20 °C -20 °C
•max. 70 °C 70 °C
Relative humidity
max. relative humidity 90 % 90 %
Mechanics/material
Plastic Yes Yes
Dimensions
Width 25 mm 45 mm
Height 30 mm 59 mm
Thickness 10 mm 12 mm
Weight
Weight without packaging 4 g; Per unit 6g; Per unit
Scope of supply
Delivery unit in items 5 5
other
Note: Comfort Panel 4" Comfort Panels 7" to 22"
ST80_2013_EN_Kap02.book Seite 133 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Fasteners
2/134 Siemens ST 80 / ST PC · 2013
2
Ordering data Order No. Order No.
Note:
This catalog only includes accessories for current products.
The complete range of accessories can be found in the Mall:
https://eb.automation.siemens.com
or on our SIMATIC Support pages:
http://support.automation.siemens.com
Mounting frame 8" Touch 6AV6671-3CS00-0AX0
For contents and matching devices,
see Technical Data and Mall
Mounting frame for 8" Key 6AV6671-3CS01-0AX0
For contents and matching devices,
see Technical Data and Mall
Mounting frame 10"/12" Touch 6AV6671-8XS00-0AX0
For contents and matching devices,
see Technical Data and Mall
Mounting clip/bracket
Plastic mounting clip 6AV6671-8XK00-0AX2
For contents and matching devices,
see Technical Data and Mall
Spring mounting clip 6AV6671-8XK00-0AX1
For contents and matching devices,
see Technical Data and Mall
Aluminum mounting clip 6AV6671-8XK00-0AX0
For contents and matching devices,
see Technical Data and Mall
Steel mounting clip 6AV6671-8XK00-0AX3
For contents and matching devices,
see Technical Data and Mall
Steel mounting bracket 6AV6671-8XK00-0AX4
For contents and matching devices,
see Technical Data and Mall
Mounts and interlocks
4" memory card lock 6AV2181-4DM10-0AX0
For contents and matching devices,
see Technical Data and Mall
7" … 22" memory card lock 6AV2181-4XM00-0AX0
For contents and matching devices,
see Technical Data and Mall
ST80_2013_EN_Kap02.book Seite 134 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Labeling strips
2/135
Siemens ST 80 / ST PC · 2013
2
Overview
Labeling strips
Protective cover for labeling strips for Mobile Panel 170,
Mobile Panel 177
Labeling strips and membranes are available for:
Text display
Multi Panel
Mobile Panel
The labeling strips, blank membranes, and protective
membranes should be printed at a printing works.
Templates can be used to create labeling strips for SIMATIC HMI
devices. Alternatively, a tool for the creation of labeling strips is
available.
Download templates from:
http://support.automation.siemens.com/WW/view/en/11274631
and
download Label Creator from:
http://support.automation.siemens.com/WW/view/en/61507590
Technical specifications
6AV6574-1AB04-
4AA0 6AV6671-5BF00-
0AX0 6AV6574-1AB00-
2BA0 6ES7272-1BF00-
7AA0 6ES7272-1AF00-
7AA0 6AV6671-0AP00-
0AX0
Protective
sleeve labeling
strips
Labeling set
Mobile
Panel 277
Labeling strip
MP 37x Key Front mem-
brane TD100C,
blank
Front mem-
brane TD200C,
blank
Front mem-
brane TD400C,
blank
Installation type/mounting
Mounting in portrait format possible Yes Yes Yes Yes Yes Yes
Mounting in landscape format possi-
ble Yes Yes Yes Yes Yes Yes
Standards, approvals, certificates
CE Yes Yes Yes Yes Yes Yes
Ambient conditions
Operating temperature
Operating temperature range, max. 50 °C 50 °C 50 °C 50 °C 50 °C 50 °C
Operating temperature range, min. C 0°C C C 0°C C
Storage/transport temperature
•Min. -20 °C -20 °C -20 °C -20 °C -20 °C -20 °C
•max. 60 °C 60 °C 60 °C 60 °C 60 °C 60 °C
Relative humidity
max. relative humidity 90 % 90 % 90 % 90 % 90 % 90 %
ST80_2013_EN_Kap02.book Seite 135 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Labeling strips
2/136 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
2
Ordering data Order No.
Note:
This catalog only includes accessories for current products.
The complete range of accessories can be found in the Mall:
https://eb.automation.siemens.com
or on our SIMATIC Support pages:
http://support.automation.siemens.com
Films
Number of films per sheet 6 6 3 2
printable with laser printer No Yes Yes Yes Yes Yes
Dimensions
Width 210 mm 210 mm 210 mm 210 mm 210 mm
Height 297 mm 297 mm 297 mm 297 mm 297 mm
Width of the housing front 163 mm
Height of housing front 91 mm
Scope of supply
Delivery unit in items 52110 10 10
Number of sets 6260 30 20
other
Note: for Mobile Panel
170, Mobile Panel
177
For Mobile Panel
277 For MP 370 Key,
MP 377 Key For TD100C For TD200C For TD400C
6AV6574-1AB04-
4AA0 6AV6671-5BF00-
0AX0 6AV6574-1AB00-
2BA0 6ES7272-1BF00-
7AA0 6ES7272-1AF00-
7AA0 6AV6671-0AP00-
0AX0
Protective
sleeve labeling
strips
Labeling set
Mobile
Panel 277
Labeling strip
MP 37x Key Front mem-
brane TD100C,
blank
Front mem-
brane TD200C,
blank
Front mem-
brane TD400C,
blank
Protective cover
for Mobile Panel 17x 6AV6574-1AB04-4AA0
For contents and matching devices,
see Technical Data in the Mall
Labeling set for Mobile Panel 277 6AV6671-5BF00-0AX0
For contents and matching devices,
see Technical Data in the Mall
Labeling set for MP 377 Key 6AV6574-1AB00-2BA0
For contents and matching devices,
see Technical Data in the Mall
Front membrane TD100C,
unprinted 6ES7272-1BF00-7AA0
For contents and matching devices,
see Technical Data in the Mall
Front membrane TD200C,
unprinted 6ES7272-1AF00-7AA0
For contents and matching devices,
see Technical Data in the Mall
Front membrane TD400C,
unprinted 6AV6671-0AP00-0AX0
For contents and matching devices,
see Technical Data in the Mall
ST80_2013_EN_Kap02.book Seite 136 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Batteries
2/137
Siemens ST 80 / ST PC · 2013
2
Overview
Rechargeable buffer battery for Mobile Panel Lithium battery for SIMATIC HMI, C7 and S7
Technical specifications
W790 84-E1001-B2 6ES7 623-1AE01-5AA0 6AV6 671-5CL00-0AX0 6AV6 671-5AD00-0AX0
Lithium battery
SIMATIC HMI and C7 Lithium battery
SIMATIC HMI, C7 and S7 Main battery Mobile Panel
IWLAN Rechargeable back-up
battery Mobile Panel
Installation type/mounting
Wall mounting/direct mounting possi-
ble Yes; in HMI devices,
battery compartment Yes; in HMI devices,
battery compartment Yes; in HMI devices,
battery compartment Yes; in HMI devices,
battery compartment
Supply voltage
Type of supply voltage DC DC DC DC
Rated voltage/DC 3.6 V; 1.6 Ah 3.6 V; 1.6 Ah 7.2 V; 5.1 Ah 3.6 V; 1.15 Ah
Battery
Design
Special design Yes; 2/3 AA Yes; 2/3 AA Yes; bent Yes; flat
Technology
• Lithium-ion Yes; SL-361 Yes; SL-361 Yes; 2ICR19/65-2 CGR Yes; 1/CP7/34/50 01 CGA
Standards, approvals, certificates
CE Yes Yes Yes Yes
Ambient conditions
Operating temperature
Operating temperature range, max. 55 °C 55 °C 55 °C 55 °C
Operating temperature range, min. C 0°C 0 °C; Don't charge below 0 °C; Don't charge below
Storage/transport temperature
•Min. -20 °C -55 °C -20 °C -20 °C
•max. 70 °C 85 °C 70 °C 70 °C
Relative humidity
max. relative humidity 90 % 90 % 90 % 90 %
Dimensions
Width 75 mm 35 mm
Height 33 mm; Length 33 mm; Length 78 mm 50 mm
Thickness 14.7 mm; Diameter 14.7 mm; Diameter 33 mm 10 mm
Weight
Weight without packaging 12 g 14 g 320 g 38 g
Scope of supply
Delivery unit in items 1; incl. 220 mm connecting
cable 1; Incl. 45 mm + 210 mm
connecting cable 11; incl. 65 mm connecting
cable
other
Note: for TD17, OP17, OP25,
OP27, OP35, OP37, TP27,
TP37, OP/TP270, MP 270,
MP 270B, MP 370, C7-621,
C7-623, C7-624, C7-626
and PG 7xx
for TD17, OP17, OP25,
OP27, OP35, OP37, TP27,
TP37, OP/TP270, MP 270,
MP 270B, MP 370, C7-621,
C7-623, C7-624, C7-626
and PG 7xx
for Mobile Panel 277
IWLAN, Mobile Panel 277F
IWLAN, Mobile Panel 277
IWLAN V2, Mobile Panel
277F IWLAN V2, Mobile
Panel 277F IWLAN (RFID
tag)
for Mobile Panel DP cabled,
Mobile Panel PN cabled,
Mobile Panel 277 IWLAN,
Mobile Panel 277F IWLAN
ST80_2013_EN_Kap02.book Seite 137 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Operator panels
SIMATIC HMI Accessories
Batteries
2/138 Siemens ST 80 / ST PC · 2013
2
Ordering data Order No.
Note:
This catalog only includes accessories for current products.
The complete range of accessories can be found in the Mall:
https://eb.automation.siemens.com
or on our SIMATIC Support pages:
http://support.automation.siemens.com
Lithium battery for SIMATIC HMI
and C7 W79084-E1001-B2
For contents and matching devices,
see Technical Data
Lithium battery for
SIMATIC PG7xx, HMI and C7 6ES7623-1AE01-5AA0
incl. 250 mm adapter cable
Main rechargeable battery for
Mobile Panel IWLAN 6AV6671-5CL00-0AX0
For contents and matching devices,
see Technical Data
Rechargeable buffer battery for
Mobile Panel 6AV6671-5AD00-0AX0
For contents and matching devices,
see Technical Data
ST80_2013_EN_Kap02.book Seite 138 Montag, 5. August 2013 10:49 10
© Siemens AG 2013
Siemens ST 80 / ST PC · 2013
3
HMI devices
for special requirements
3/2 Introduction
3/3 Fully enclosed HMI devices
3/4 SIMATIC MP 377 PRO
3/7 SIMATIC HMI IPC477C PRO
3/12 SIMATIC Flat Panel PRO
3/14 SIMATIC Thin Client PRO
3/16 Accessories
for fully enclosed HMI devices
3/16 Adapter sets
3/17 Extension units
3/19 IP65 keyboards
3/20 USB interfaces
3/21 Devices with stainless steel front
3/22 SIMATIC HMI IPC677C INOX
3/25 HMI devices for hazardous areas
3/26 SIMATIC HMI Panel PC Ex
3/30 SIMATIC HMI Thin Client Ex
ST80_2013_EN_Kap03.book Seite 1 Mittwoch, 31. Juli 2013 3:24 15
© Siemens AG 2013
HMI devices for special requirements
Introduction
3/2 Siemens ST 80 / ST PC · 2013
3
Overview
Fully enclosed HMI devices
The fully enclosed SIMATIC HMI devices (MP 377 PRO,
HMI IPC477C PRO, Flat Panel PRO and Thin Client PRO) are
specially designed for mounting on a support arm/stand. Thanks
to their extremely rugged design, the devices are ideal for indus-
trial applications in harsh environments.
Devices with stainless steel front
For special requirements, the HMI IPC677C INOX with stainless
steel front for use in the food and beverages industry.
HMI devices for hazardous areas
The SIMATIC HMI Ex devices (HMI Panel PC Ex and HMI Thin
Client Ex) are intrinsically safe Panel PCs and Thin Clients that
have been specially developed for hazardous areas "Zone 1"
and "Zone 2". Further SIMATIC HMI devices are also available for
the hazardous area "Zone 2" and can be found in the chapter
"Operator panels".
ST80_2013_EN_Kap03.book Seite 2 Mittwoch, 31. Juli 2013 3:24 15
© Siemens AG 2013
HMI devices for special requirements
Fully enclosed HMI devices
Overview
3/3
Siemens ST 80 / ST PC · 2013
Overview
The SIMATIC HMI PRO (PRO = protected) devices have been
designed for mounting on a support arm/pedestal. Thanks to
their rugged aluminum enclosures, the SIMATIC HMI PRO
devices offer overall IP65 protection and are also suitable for use
in harsh environments. The separation of HMI and control
cabinet allows flexible design concepts.
The SIMATIC HMI PRO devices are used wherever the HMI
device cannot be installed direct in the control cabinet due to
restricted space, or whenever an operator control unit is
required direct at the machine. All the devices are fan-free,
and only standard connecting cables are used.
The SIMATIC HMI PRO devices can be mounted direct on the
support arm head of the desired support arm system using the
basic adapter supplied. The adapter set can be ordered
separately. The basic adapter can be attached to the top or
bottom of the device. The connecting cables are run through the
support arm.
With the extension units, the range of possible on-site operations
can be expanded. The extension units can be mounted on the
right and/or left side of the SIMATIC HMI PRO device and can be
equipped individually with, for example, illuminated
pushbuttons, emergency stop buttons, RFID readers, etc.
The following are available as SIMATIC fully enclosed
HMI devices:
SIMATIC MP 377 PRO 15" Touch:
Multi Panel for operator control and monitoring of machines
and plants
SIMATIC HMI IPC477C PRO 15"/19" Touch:
Compact, high-performance and maintenance-free
embedded IPC
SIMATIC Flat Panel PRO 15"/19" Touch:
Industrial monitor with touch functionality, can be located up
to 30 m from the operator control unit
(as with Flat Panel Extended)
SIMATIC Thin Client PRO 15" Touch:
HMI device for terminal and web client applications
ST80_2013_EN_Kap03.book Seite 3 Mittwoch, 31. Juli 2013 3:24 15
© Siemens AG 2013
HMI devices for special requirements
Fully enclosed HMI devices
SIMATIC MP 377 PRO
3/4 Siemens ST 80 / ST PC · 2013
3
Overview
SIMATIC MP 377 PRO 15"
Technical specifications
MP 377 PRO 15" 6AV6 644-2AB01-2AX0
Display
Size 15" (304.1 mm x 228.1 mm)
Display type TFT, 65536 colors
Resolution (pixels)
• Resolution (WxH in pixel) 1024 x 768
Backlighting
• MTBF backlighting (at 25 °C) about 50000 hours
Control elements
Control elements Touch screen
Connection for mouse/keyboard/
barcode reader USB / USB / USB
Touch operation
• Touch screen Analog, resistive
Supply voltage
Supply voltage 24 V DC
Input current
Rated current 1.8 A
Memory
Type Flash / RAM
Usable memory for user data 12288 KB usable memory for user
data / 12288 KB additional memory
for options
Time of day
Clock
• Type Hardware clock, battery backup,
synchronizable
Interfaces
Interfaces 1 x RS422, 1 x RS485,
2 x Ethernet (RJ45)
USB port 2 x USB
CF card slot 1 x CF card slot
Multi Media Card slot 1 x Multi Media Card slot
Industrial Ethernet
• Industrial Ethernet interface 2 x Ethernet (RJ45)
Protocols
Protocols (terminal link)
•Sm@rtServer Yes
Degree and class of protection
Front IP65, NEMA 4, (when installed)
Rear IP65
Standards, approvals, certificates
Certifications CE, cULus, C-TICK, NEMA 4
FM Class I Div. 2 No
Suitable for safety functions No
Use in hazardous areas
• EX zone 22 No
ST80_2013_EN_Kap03.book Seite 4 Mittwoch, 31. Juli 2013 3:24 15
© Siemens AG 2013
HMI devices for special requirements
Fully enclosed HMI devices
SIMATIC MP 377 PRO
3/5
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
Ambient conditions
Mounting position vertical
maximum permissible angle of
inclination without external ventilation +/- 45 °
Operating temperature
•Operation 0 °C to +45 °C
Storage/transport temperature
• Transport, storage -20 °C to +60 °C
Relative humidity
• max. relative humidity 85 %
Operating systems
Operating system Windows CE
Configuration
Configuration software
• Configuration tool WinCC flexible Standard Version
2008 or higher (to be ordered
separately)
Languages
Online languages
Number of online/runtime languages 5
Functionality under
WinCC (TIA Portal)
Libraries Yes
Task planner Yes
With alarm logging system
(incl. buffer and acknowledgment)
Number of messages 4 000
Bit messages Yes
Analog messages Yes
Recipes
Number of recipes 500
Data records per recipe 1 000
Entries per data record 1 000
Recipe memory 128 KB integrated Flash,
expandable
Variables
Number of variables per device 4 096; Configuration with
WinCC flexible 2008 and higher
Limit values Yes
• Multiplexing Yes
Images
• Number of configurable images 500
Image objects
• Text objects 30000 text elements
Graphics object Bit maps, icons, vector graphics
Complex image objects
• Status/control With SIMATIC S7
dynamic objects Diagrams, bar graphs, sliders,
analog display, invisible buttons
MP 377 PRO 15" 6AV6 644-2AB01-2AX0
Functionality under
WinCC (TIA Portal) (continued)
Lists
• Number of text lists per project 500
• Number of graphics lists per project 500
Archiving
• Number of archives per device 50
• Number of measuring points per
project 50
• Number of entries per archive 50 000
• external evaluation Readable, e.g. with MS Excel,
MS Access, etc.
• Size of archive depending on free memory on ext.
card/stick or on free hard disk space
via network drive
Security
• Number of user groups 50
• Number of user rights 32
• Password export/import Yes
Data carrier support
• CF card Yes
Logging through printer
• Recording/Printing Alarms, report (shift report), color
print, hardcopy
Transfer (upload/download)
• Transfer of configuration MPI/PROFIBUS DP, serial, USB,
Ethernet, by means of external
storage medium, automatic transfer
recognition
Process coupling
• Connection to controller S5, S7-200, S7-300/400, TI 505,
Win AC, PC (TCP/IP), SINUMERIK,
SIMOTION, Allen Bradley (DF1),
Allen Bradley (DF485), Mitsubishi
(FX), OMRON (LINK/Multilink),
Modicon (Modbus),
further non-Siemens drivers,
see chapter "System interfaces"
• S7-1200 Yes
• S7-1500 Yes
Expandability/openness
• Open Platform Program Yes
I/O
I/O devices Printer, card reader, barcode reader
• Multi Media Card Yes
Dimensions
Front of enclosure (W x H) 400 mm x 310 mm
Weight
Weight 7.25 kg
MP 377 PRO 15" 6AV6 644-2AB01-2AX0
ST80_2013_EN_Kap03.book Seite 5 Mittwoch, 31. Juli 2013 3:24 15
© Siemens AG 2013
HMI devices for special requirements
Fully enclosed HMI devices
SIMATIC MP 377 PRO
3/6 Siemens ST 80 / ST PC · 2013
3
Ordering data
Order No.
Note:
An adapter plate is required for mounting on the support arm
systems of well-known manufacturers; see "Accessories for fully
enclosed HMI devices".
Dimensional drawings
All dimensions in mm. For installation cutout, see technical
specifications.
SIMATIC MP 377 PRO 15" Touch
More information
Additional information is available on the Internet at:
http://www.siemens.com/ip65-hmi-devices
Note:
Do you require a specific modification or extension to the
products described here? Under "Customized products" you
can find information about additional and generally available
products for the sector, and about the possibilities for
customized modification and adaptation.
SIMATIC MP 377 PRO 15" Touch 6AV6644-2AB01-2AX0
15" color TFT display,
12 MB configuration memory,
can be configured from
WinCC Comfort (TIA Portal)
or from WinCC flexible 2008
400
310
67.85
98.5
G_ST80_XX_00351
ST80_2013_EN_Kap03.book Seite 6 Mittwoch, 31. Juli 2013 3:24 15
© Siemens AG 2013
HMI devices for special requirements
Fully enclosed HMI devices
SIMATIC HMI IPC477C PRO
3/7
Siemens ST 80 / ST PC · 2013
Overview
SIMATIC HMI IPC477C PRO 19" SIMATIC HMI IPC477C PRO 19" (rear view)
Technical specifications
HMI IPC477C PRO 6AV7 883-6….-…. 15" 6AV7 883-7….-…. 19"
General features
Supply voltage 24 V DC 24 V DC
Processors Intel Celeron M 1.2 GHz, Intel Core2 Solo 1.2 GHz or
Core2 Duo 1.2 GHz Intel Celeron M 1.2 GHz, Intel Core2 Solo 1.2 GHz or
Core2 Duo 1.2 GHz
Memory type DDR3-RAM DDR3-RAM
Main memory 1 GB, 2 GB or 4 GB 1 GB, 2 GB or 4 GB
free slots 1 x CF card slot 1 x CF card slot
Operating system Windows Embedded Standard 2009,
Windows Embedded Standard 7, Windows 7,
or Windows XP Professional Multi Language
Windows Embedded Standard 2009,
Windows Embedded Standard 7, Windows 7,
or Windows XP Professional Multi Language
Additional OS information Language: EN/DE Language: EN/DE
SIMATIC Software Optionally with pre-installed bundle software
SIMATIC WinCC flexible 2008 or WinCC RT Advanced
and/or SIMATIC WinAC RTX / RTX F 2010,
SIMATIC WinCC or WinCC RT Professional as web client
or standard client
Optionally with pre-installed bundle software
SIMATIC WinCC flexible 2008 or WinCC RT Advanced
and/or SIMATIC WinAC RTX / RTX F 2010,
SIMATIC WinCC or WinCC RT Professional as web client
or standard client
Drives
Floppy drive optional via external USB floppy drive optional via external USB floppy drive
Optical drives possible as an external drive via USB possible as an external drive via USB
Hard disk/mass storage CompactFlash drive with 4, 8, or 16 GB
and/or 50 GB SSD (High Endurance) CompactFlash drive with 4, 8, or 16 GB
and/or 50 GB SSD (High Endurance)
ST80_2013_EN_Kap03.book Seite 7 Mittwoch, 31. Juli 2013 3:24 15
© Siemens AG 2013
HMI devices for special requirements
Fully enclosed HMI devices
SIMATIC HMI IPC477C PRO
3/8 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
3
Interfaces
Graphics interface DVI-I can be used for additional display unit
(only VGA via adapter); 32-bit color depth, graphics
memory up to 128 MB; resolution as for integrated
display in each case
DVI-I can be used for additional display unit
(only VGA via adapter); 32-bit color depth, graphics
memory up to 128 MB; resolution as for integrated
display in each case
Connection for keyboard/mouse USB / USB USB / USB
serial interface COM1: 1 x V.24 (RS232) COM1: 1 x V.24 (RS232)
PROFIBUS/MPI Optionally onboard, isolated, max. 12 Mbit/s, no plug-in
card required, CP5611-compatible, not upgradable Optionally onboard, isolated, max. 12 Mbit/s, no plug-in
card required, CP5611-compatible, not upgradable
PROFINET (RT/IRT) Optional: 3 x RJ45, CP1616-compatible; not for retrofitting Optional: 3 x RJ45, CP1616-compatible; not for retrofitting
USB 4 x on rear, USB 2.0 (500 mA) 4 x on rear, USB 2.0 (500 mA)
PROFINET (IE), Ethernet onboard, 2 x 10/100/1000 Mbit (RJ45 without/with
PROFIBUS), 1 x 10/100/1000 Mbit (RJ45 with PROFINET),
no plug-in card necessary
onboard, 2 x 10/100/1000 Mbit (RJ45 without/with
PROFIBUS), 1 x 10/100/1000 Mbit (RJ45 with PROFINET),
no plug-in card necessary
Multimedia No No
Monitoring functions
Temperature Yes Yes
Watchdog Yes Yes
DiagBit (similar to S.M.A.R.T.) Yes (for CF cards and SSD) Yes (for CF cards and SSD)
Status LEDs Yes Yes
Front side according to EN 60529 IP65 all-round to EN 60529 and NEMA4 IP65 all-round to EN 60529 and NEMA4
Ambient conditions
Vibration load during operation Tested according to DIN IEC 60068-2-6: 10 to 58 Hz:
0.075 mm, 58 to 200 Hz: 9.8 m/s² (1 g) Tested according to DIN IEC 60068-2-6: 10 to 58 Hz:
0.075 mm, 58 to 200 Hz: 9.8 m/s² (1 g)
Shock loading during operation Tested according to DIN IEC 60068-2-7:
50 m/s² (5 g), 30 ms, 100 shocks Tested according to DIN IEC 60068-2-7:
50 m/s² (5 g), 30 ms, 100 shocks
Relative humidity Tested according to DIN IEC 68-78, DIN IEC 60068-2-30:
5 % to 80 % at 25 °C (no condensation) Tested according to DIN IEC 68-78, DIN IEC 60068-2-30:
5 % to 80 % at 25 °C (no condensation)
maximum permissible installation
angle +/- +/- 45° from the vertical +/- 45° from the vertical
Ambient temperature C to 45 °C 0°C to 40°C
Certifications & standards
Approvals CE, cULus(508) CE, cULus(508)
EMC CE, 55022A, EN 61000-6-4, EN 61000-6-2 CE, 55022A, EN 61000-6-4, EN 61000-6-2
Degree of protection Overall device IP65/enclosure type 4x/type 12
(indoor use only) Overall device IP65/enclosure type 4x/type 12
(indoor use only)
Dimensions 400 mm x 310 mm x 98 mm 483 mm x 400 mm x 115 mm
Weight 7.4 kg 10.9 kg
HMI IPC477C PRO 6AV7 883-6….-…. 15" 6AV7 883-7….-…. 19"
ST80_2013_EN_Kap03.book Seite 8 Mittwoch, 31. Juli 2013 3:24 15
© Siemens AG 2013
HMI devices for special requirements
Fully enclosed HMI devices
SIMATIC HMI IPC477C PRO
3/9
Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
IPC477C PRO as "Built to Order" versions
(max. delivery time is 15 working days and with identified repair).
SIMATIC HMI IPC477C PRO
optionally with
WinAC / WinCC flexible
6AV7883-
7A7 7 7 -7770
Embedded and fan-free, with IP65
housing with all-round protection;
5 x USB (500 mA),
1 of which on the front
24 V DC power supply
with On/Off switch
Front panels
15" TFT Touch (IP65 enclosure) 6
19" TFT Touch (IP65 enclosure) 7
Processors and fieldbus
• Celeron M 1.2 GHz,
2 x PROFINET (IE) A
• Celeron M 1.2 GHz,
2 x PROFINET (IE),
1 x PROFIBUS DP 12
B
• Core2 Solo 1.2 GHz,
2 x PROFINET (IE) D
• Core2 Solo 1.2 GHz,
2 x PROFINET (IE),
1 x PROFIBUS DP 12
E
• Core2 Solo 1.2 GHz,
1 x PROFINET (IE),
1 x PROFINET (3 ports)
F
Core2 Duo 1.2 GHz,
2 x PROFINET (IE) G
Core2 Duo 1.2 GHz,
2 x PROFINET (IE),
1 x PROFIBUS DP 12
H
Core2 Duo 1.2 GHz,
1 x PROFINET (IE),
1 x PROFINET (3 ports)
J
Main memory
(DDR3 RAM), 1 database
•1 GB 1
•2 GB 2
•4 GB 3
Mass storage swappable
(formatted with a partition)
• None 0
• CompactFlash 2 GB 2
• CompactFlash 4 GB 3
• CompactFlash 8 GB 4
• CompactFlash 16 GB 5
50 GB SSD (High Endurance) 6
Mass storage
(with Windows Embedded Standard
2009 (EN/DE) / Windows Embedded
Standard 7 pre-installed and
optionally with SIMATIC software)
• CompactFlash 2 GB
(only with Windows Embedded
Standard 2009)
2
• CompactFlash 4 GB 3
• CompactFlash 8 GB 4
• CompactFlash 16 GB 5
50 GB SSD (High Endurance) 6
SIMATIC HMI IPC477C PRO
optionally with
WinAC / WinCC flexible (continued)
6AV7883-
7A7 7 7 -7 7 7 0
Operating system
(pre-installed and activated)
• Windows Embedded Standard
2009 B A
• Windows XP Professional
Multi-Language, only with SSD;
without SIMATIC software
D A
• Windows Embedded Standard 7
SP1, pre-installed on internal drive,
CF > 4 GB, SSD, and 2 GB main
memory
E A
• Windows 7 Ultimate, MUI (Eng,
Ger, Fr, It, Sp) pre-installed on SSD G A
Software packages
WinAC / WinCC flexible
CF 4 GB or more and SSD,
only together with
Windows Embedded Standard 2009
or Windows Embedded Standard 7
• With WinAC RTX
pre-installed and configured
for PROFIBUS and with
WinCC flexible 2008 RT
(incl. Archives/Recipes)
pre-installed and configured
B
- Number of tags 128 PT C
- Number of tags 512 PT D
- Number of tags 2048 PT E
- Number of tags 4096 PT F
• With WinAC RTX and WinCC flexi-
ble 2008 RT (incl. Archives/Reci-
pes) pre-installed and configured
- Number of tags 128 PT K
- Number of tags 512 PT L
- Number of tags 2048 PT M
- Number of tags 4096 PT N
• With WinAC RTX F
pre-installed and configured for
PROFIBUS DP 12
P
- Number of tags 128 PT R
• With WinAC RTX F and
WinCC flexible 2008 RT
(incl. Archives/Recipes),
pre-installed and configured
- Number of tags 512 PT S
- Number of tags 2048 PT T
- Number of tags 4096 PT U
ST80_2013_EN_Kap03.book Seite 9 Mittwoch, 31. Juli 2013 3:24 15
© Siemens AG 2013
HMI devices for special requirements
Fully enclosed HMI devices
SIMATIC HMI IPC477C PRO
3/10 Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
3
Note:
An adapter plate is required for mounting on the support arm
systems of well-known manufacturers; see "Accessories for fully
enclosed HMI devices".
For further bundles with SIMATIC HMI IPC477C PRO with
SIMATIC WinCC V7.0 and SIMATIC WinCC RT Professional
(TIA Portal), see under SIMATIC HMI IPC477C bundles
SIMATIC HMI IPC477C PRO
optionally with
WinAC / WinCC RT Advanced
6AV7883-
7A7 7 7 -7 7 7 1
Embedded and fan-free, with IP65
housing with all-round protection;
5 x USB (500 mA),
1 of which on the front
24 V DC power supply
with On/Off switch
Front panels
15" TFT Touch (IP65 enclosure) 6
19" TFT Touch (IP65 enclosure) 7
Processors and fieldbus
• Celeron M 1.2 GHz,
2 x PROFINET (IE) A
• Celeron M 1.2 GHz,
2 x PROFINET (IE),
1 x PROFIBUS DP 12
B
• Core2 Solo 1.2 GHz,
2 x PROFINET (IE) D
• Core2 Solo 1.2 GHz,
2 x PROFINET (IE),
1 x PROFIBUS DP 12
E
• Core2 Solo 1.2 GHz,
1 x PROFINET (IE),
1 x PROFINET (3 ports)
F
Core2 Duo 1.2 GHz,
2 x PROFINET (IE) G
Core2 Duo 1.2 GHz,
2 x PROFINET (IE),
1 x PROFIBUS DP 12
H
Core2 Duo 1.2 GHz,
1 x PROFINET (IE),
1 x PROFINET (3 ports)
J
Main memory
(DDR3 RAM),1 database
•2 GB 2
•4 GB 3
Mass storage, removable
• None 0
• CompactFlash 2 GB
(only with Windows Embedded
Standard 2009)
2
• CompactFlash 4 GB 3
• CompactFlash 8 GB 4
• CompactFlash 16 GB 5
50 GB SSD (High Endurance) 6
Mass storage, installed
(Windows Embedded Standard 7
pre-installed and optionally with
SIMATIC software)
• CompactFlash 4 GB 3
• CompactFlash 8 GB 4
• CompactFlash 16 GB 5
50 GB SSD (High Endurance) 6
SIMATIC HMI IPC477C PRO
optionally with
WinAC / WinCC RT Advanced
(continued)
6AV7883-
7A7 7 7 -7 7 7 1
Operating system
(pre-installed and activated)
• Windows Embedded Standard 7,
pre-installed on internal drive E A
Software packages
WinAC / WinCC RT Advanced
• With WinAC RTX
pre-installed and configured
for PROFIBUS and with
WinCC RT Advanced
(incl. Logging & Recipes)
pre-installed and configured
B
- Number of tags 128 PT C
- Number of tags 512 PT D
- Number of tags 2048 PT E
- Number of tags 4096 PT F
• With WinAC RTX and
WinCC RT Advanced
(incl. Logging & Recipes)
pre-installed and configured
- Number of tags 128 PT K
- Number of tags 512 PT L
- Number of tags 2048 PT M
- Number of tags 4096 PT N
• With WinAC RTX F
pre-installed and configured
for PROFIBUS DP 12
P
• With WinAC RTX F and WinCC RT
Advanced (incl. Logging & Reci-
pes) pre-installed and configured
- Number of tags 128 PT R
- Number of tags 512 PT S
- Number of tags 2048 PT T
- Number of tags 4096 PT U
ST80_2013_EN_Kap03.book Seite 10 Mittwoch, 31. Juli 2013 3:24 15
© Siemens AG 2013
HMI devices for special requirements
Fully enclosed HMI devices
SIMATIC HMI IPC477C PRO
3/11
Siemens ST 80 / ST PC · 2013
Dimensional drawings
All dimensions in mm. For installation cutout, see technical specifications.
SIMATIC HMI IPC477C PRO 15" Touch version SIMATIC HMI IPC477C PRO 19" Touch version
More information
Additional information is available on the Internet at:
http://www.siemens.com/ip65-hmi-devices
Note:
Do you require a specific modification or extension to the
products described here? Under "Customized products" you
can find information about additional and generally available
products for the sector, and about the possibilities for
customized modification and adaptation.
348.7
G_ST80_XX_00400
105
400 482.7
81.85
78.85
G_ST80_XX_00401
119 400
ST80_2013_EN_Kap03.book Seite 11 Mittwoch, 31. Juli 2013 3:24 15
© Siemens AG 2013
HMI devices for special requirements
Fully enclosed HMI devices
SIMATIC Flat Panel PRO
3/12 Siemens ST 80 / ST PC · 2013
3
Overview
SIMATIC Flat Panel Monitor PRO 19" SIMATIC Flat Panel Monitor PRO 15" with expansion unit (rear view)
Technical specifications
Flat Panel PRO 15" PRO 19"
Supply voltage
Supply voltage 24 V DC and
230 V AC
combined
24 V DC and
230 V AC
combined
permissible frequency range 47 to 63 Hz 47 to 63 Hz
Power consumption, max. 35 VA 35 VA
General features
Can be separate from the computer up to 30 m up to 30 m
Display
On-screen display (OSD)
configuration Yes Yes
Display version 15" TFT 19" TFT
visible area (H x W) in mm 304 x 228 376 x 301
Viewing angle 140° x 120°
(min) 140° x 120°
(min)
Pixel pitch 0.297 mm x
0.297 mm 0.297 mm x
0.297 mm
Resolution (W x H in pixels) 1024 x 768 1280 x 1024
Refresh rate 60 to 75 Hz 60 to 75 Hz
Line frequency 46.7 - 80 kHz 46.7 - 80 kHz
Brightness/contrast > 260 cd/m
2
/
350:1 > 300 cd/m
2
/
300:1
Number of colors 16.7 million 16.7 million
MTBF of backlit display (at 25 °C,
24 hours continuous operation) 50,000 h 50,000 h
Type of operation
Touch screen analog-resistive analog-resistive
Connection for keyboard/mouse/
barcode reader Yes, via USB Yes, via USB
Degree of protection Overall device
IP65/enclosure
type 4x/type 12
(indoor use only)
Overall device
IP65/enclosure
type 4x/type 12
(indoor use only)
Certifications & standards
Certification cULus (UL 508),
NEMA4-tested cULus (UL 508),
NEMA4-tested
EMC CE EN 55011
class A CE EN 55011
class A
Standards, approvals, certificates
CE mark Yes Yes
UL approval Yes Yes
Ambient conditions
Vibration load during operation 1 g (10 m/s²) 1 g (10 m/s²)
Shock loading during operation 5 g (50 m/s²) 5 g (50 m/s²)
Temperature
• Ambient temperature during opera-
tion 5 to +45 °C 5 to +45 °C
Mounting
Inclination angle +/- 45° from the
vertical +/- 45° from the
vertical
Interfaces
Graphics interface Standard VGA
interface 15-pin
sub-D/digital
DVI-D interface
Standard VGA
interface 15-pin
sub-D/digital
DVI-D interface
Interface for Touch USB (V1.1) USB (V1.1)
USB interface for touch screen Yes Yes
Dimensions
External dimensions (W x H x D) 400 mm x 310
mm x 91 mm 483 mm x 400
mm x 105 mm
Weight
Weight 6.7 kg 10 kg
Flat Panel PRO 15" PRO 19"
ST80_2013_EN_Kap03.book Seite 12 Mittwoch, 31. Juli 2013 3:24 15
© Siemens AG 2013
HMI devices for special requirements
Fully enclosed HMI devices
SIMATIC Flat Panel PRO
3/13
Siemens ST 80 / ST PC · 2013
Ordering data
Order No.
Note:
An adapter plate is required for mounting on the support arm
systems of well-known manufacturers; see "Accessories for fully
enclosed HMI devices".
Dimensional drawings
All dimensions in mm. For installation cutout, see technical
specifications.
SIMATIC Flat Panel PRO 15" Touch
SIMATIC Flat Panel PRO 19" Touch
More information
Additional information is available on the Internet at:
http://www.siemens.com/ip65-hmi-devices
Note:
Do you require a specific modification or extension to the
products described here? Under "Customized products" you
can find information about additional and generally available
products for the sector, and about the possibilities for
customized modification and adaptation.
SIMATIC Flat Panel PRO 15"
Touch 6AV7861-5TB10-1BA0
SIMATIC Flat Panel PRO 19"
Touch 6AV7861-6TB10-1BA0
400
310
67.85
90.85
G_ST80_XX_00350
G_ST80_XX_00371
82
105
483
400
SIMATIC FLAT PANEL
ST80_2013_EN_Kap03.book Seite 13 Mittwoch, 31. Juli 2013 3:24 15
© Siemens AG 2013
HMI devices for special requirements
Fully enclosed HMI devices
SIMATIC Thin Client PRO
3/14 Siemens ST 80 / ST PC · 2013
3
Overview
SIMATIC Thin Client PRO 15"
Technical specifications
Thin Client PRO 15" Touch 6AV6646-2AB21-2AX0
Display
Size 15.1"
Display type TFT, 65536 colors
Resolution (pixels)
• Resolution (WxH in pixel) 1024 x 768
Backlighting
• MTBF backlighting (at 25 °C) about 50000 hours
Control elements
Control elements Touch screen
Connection for mouse/keyboard/
barcode reader USB / USB
Touch operation
• Touch screen Analog, resistive
Supply voltage
Supply voltage 24 V DC
Processor
Processor ARM, 266 MHz
Memory
Type Flash / RAM
Usable memory for user data No info
Interfaces
Interfaces 1 x Ethernet (RJ45)
USB port 1 x USB
Industrial Ethernet
• Industrial Ethernet interface 1 x Ethernet (RJ45)
Protocols
WEB characteristics
• HTTP Yes
•HTML Yes
•CSS Yes
Protocols (terminal link)
•Sm@rtServer Yes
•RDP Yes
EMC
Emission of radio interference
acc. to EN 55 011
• Emission of radio interferences
acc. to EN 55 011 (limit class A) Yes; EN 61000-6-4, interference
emission: Intended for use in
industrial areas.
Degree and class of protection
Front IP65, NEMA 4x, NEMA 12
(when installed)
Rear IP65
Standards, approvals, certificates
Certifications CE, cULus, C-TICK,
NEMA 4x (Enclosure Type 4X,
Type 12), NEMA 12
EMC The product is designed for use in
industrial environments. When used
in residential areas, the emission of
radio interference according to limit
class B of EN 55011 must be
ensured. For further information
please refer to the user documenta-
tion.
Suitable for safety functions No
ST80_2013_EN_Kap03.book Seite 14 Mittwoch, 31. Juli 2013 3:24 15
© Siemens AG 2013
HMI devices for special requirements
Fully enclosed HMI devices
SIMATIC Thin Client PRO
3/15
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
Ordering data
Order No.
Note:
An adapter plate is required for mounting on the support arm
systems of well-known manufacturers; see "Accessories for fully
enclosed HMI devices".
Ambient conditions
maximum permissible angle of
inclination without external ventilation +/- 45 °
Operating temperature
•Operation 0 °C to +45 °C
Storage/transport temperature
• Transport, storage -20 °C to +60 °C
Relative humidity
• max. relative humidity 85 %; (Storage)
Dimensions
Front of enclosure (W x H) 400 mm x 310 mm
Weight
Weight 6.5 kg
SIMATIC Thin Client PRO 15"
Touch 6AV6646-2AB21-2AX0
Starter packages
SIMATIC Thin Client with
Sm@rtAccess
Touch device 15" PRO with
Sm@rtAccess license (panels) 6AV6653-6CA01-2AA0
Touch device 15" PRO with
Sm@rtAccess license for
WinCC flexible 2008 Runtime
6AV6653-6FA01-2AA0
Thin Client PRO 15" Touch 6AV6646-2AB21-2AX0
Dimensional drawings
All dimensions in mm. For installation cutout, see technical
specifications.
SIMATIC Thin Client PRO 15" Touch
More information
Additional information is available on the Internet at:
http://www.siemens.com/ip65-hmi-devices
Note:
Do you require a specific modification or extension to the
products described here? Under "Customized products" you
can find information about additional and generally available
products for the sector, and about the possibilities for
customized modification and adaptation.
400
310
67.85
90.85
G_ST80_XX_00350
ST80_2013_EN_Kap03.book Seite 15 Mittwoch, 31. Juli 2013 3:24 15
© Siemens AG 2013
HMI devices for special requirements
Accessories for fully enclosed HMI devices
Adapter sets
3/16 Siemens ST 80 / ST PC · 2013
3
Overview
Adapter sets
The adapter sets are required for connecting the
SIMATIC HMI PRO device with the support arm head of the
respective support arm system
By directly connecting the support arm head to the device,
there is complete flexibility in the choice of support arm
components
Adapter sets are available for the VESA 75 and
VESA 100 systems.
Further adapter sets can be obtained directly from the
respective supporting bracket manufacturer: Bernstein, Rittal,
Rose and Haseke
Ordering data
Order No.
1)
The VESA 100 adapter set cannot be used in combination
with the 19" Flat Panel PRO.
Note:
The internal diameter of the 48 mm supporting bracket tubes is
not suitable for passage of the standard DVI-D cable.
Scope of delivery:
One basic adapter or one adapter plate
Mounting hardware
More information
Additional information is available on the Internet at:
http://www.siemens.com/ip65-hmi-devices
Note:
Do you require a specific modification to or option for the
products described here? Under "Customized products" you
can find information about additional and generally available
products for the sector, and about the possibilities for
customized modification and adaptation.
VESA 100 adapter set
1)
for 6AV7674-0KD00-0AA0
• VESA 100
Rose GTN II
Adapter set VESA 75 for 6AV7674-0KE00-0AA0
• VESA 75
Replacement basic adapter,
suitable for
SIMATIC HMI PRO devices
6AV7674-0KA00-0AA0
ST80_2013_EN_Kap03.book Seite 16 Mittwoch, 31. Juli 2013 3:24 15
© Siemens AG 2013
HMI devices for special requirements
Accessories for fully enclosed HMI devices
Extension units
3/17
Siemens ST 80 / ST PC · 2013
Overview
Extension units
With the extension units, the range of possible on-site operations
can be extended. They are mounted on the SIMATIC HMI PRO
device and can be equipped individually, e.g. with Key Panel
(KP8), 3SB elements, emergency stop buttons, key switches,
RFID reader, etc.
They can be mounted on the left or right side of the
PRO device, as required
Direct installation of up to 2 Key Panels KP8 / KP8F
IP65 - cable routing
Can be equipped individually
For all 15"/19" PRO devices
The combination of HMI PRO device and KP8 PN offers the
following advantages:
No control cabinet required
Low cabling overhead
Optimally coordinated design
Ordering data
Order No.
Extension Unit 15" 6AV7674-0KG00-0AA0
For mounting on all 15" PRO devices
Extension Unit 15" KP8 6AV7674-0KG01-0AA0
For mounting on all 15" PRO devices
for direct installation of up to
2 KP8 / KP8F
Starter package Extension Unit
15" with KP8 6AV7674-0KG11-0AA0
1 x Extension Unit 15" KP8,
1 x Key Panel 8 PN,
1 x blank front
Extension Unit 19" right 6AV7674-0KJ00-0AA0
• For support arm mounting
from above
Mounting of the Extension Unit on
the right side of the 19" PRO device
• For support arm mounting
from below
Mounting of the Extension Unit on
the left side of the 19" PRO device
Extension Unit 19" KP8 right 6AV7674-0KJ01-0AA0
• For support arm mounting
from above
Mounting of the Extension Unit on
the right side of the 19" PRO device
• For support arm mounting
from below
Mounting of the Extension Unit on
the left side of the 19" PRO device
• For direct installation of
up to 2 KP8 / KP8F
Starter package Extension Unit
19" with KP8 right 6AV7674-0KJ11-0AA0
1 x Extension Unit 19" KP8 right,
1 x Key Panel 8 PN,
1 x blank front
Extension Unit 19" left 6AV7674-0KH00-0AA0
• For support arm mounting
from above
Mounting of the Extension Unit on
the left side of the 19" PRO device
• For support arm mounting
from below
Mounting of the Extension Unit on
the right side of the 19" PRO device
Starter package Extension Unit
19" with KP8 left 6AV7674-0KH11-0AA0
1 x Extension Unit 19" KP8 left,
1 x Key Panel 8 PN,
1 x blank front
Extension Unit 19" KP8 left 6AV7674-0KH01-0AA0
• For support arm mounting
from above
Mounting of the Extension Unit on
the left side of the 19" PRO device
• For support arm mounting
from below
Mounting of the Extension Unit on
the right side of the 19" PRO device
• For direct installation of up to
2 KP8 / KP8F
ST80_2013_EN_Kap03.book Seite 17 Mittwoch, 31. Juli 2013 3:24 15
© Siemens AG 2013
HMI devices for special requirements
Accessories for fully enclosed HMI devices
Extension units
3/18 Siemens ST 80 / ST PC · 2013
Ordering data
Order No.
3
Scope of delivery:
1 Extension Unit box
1 front plate for the Extension Unit
1 connecting tube
Mounting accessories
KP8 front plate
for the Extension Unit 6AV7674-0KH30-0AB0
For installing up to two KP8
in an Extension Unit
Suitable for all 15" and 19"
Extension Units
Empty front KP8 design
in combination
with front panel KP8
6AV3688-3XY38-3AX0
Spare front plate
for the Extension Unit 6AV7674-0KH30-0AA0
Suitable for all 15" and 19"
Extension Units
Required if the front plate supplied
with the Extension Unit must be re-
placed
More information
Additional information is available on the Internet at:
http://www.siemens.com/ip65-hmi-devices
Note:
Do you require a specific modification to or option for the
products described here? Under "Customized products" you
can find information about additional and generally available
products for the sector, and about the possibilities for
customized modification and adaptation.
ST80_2013_EN_Kap03.book Seite 18 Mittwoch, 31. Juli 2013 3:24 15
© Siemens AG 2013
HMI devices for special requirements
Accessories for fully enclosed HMI devices
IP65 keyboards
3/19
Siemens ST 80 / ST PC · 2013
Overview
IP65 keyboards
With the stainless steel IP65 keyboards, the range of possible
on-site operations can be extended. They are mounted on the
SIMATIC HMI PRO device underneath the base adapter, and
they are available in two versions.
Anti-twist and non-removable stainless steel key caps
Abrasion-resistant laser labeling
(depth engraving with annealing marking)
Secure, pleasant key feel
Maximum user-friendliness thanks to withdrawable
long-stroke key
Windows layout (EN/US) with two additional keys
(left and right mouse key function) via cursor block
USB interface
Angle-adjustable connection for optimal ergonomics
Water and dust protection in accordance with degree of
protection IP65
For all 15"/19" PRO devices
Ordering data
Order No.
Scope of delivery:
One stainless steel IP65 keyboard incl. mounting adapter for
PRO devices
Mounting accessories
More information
Additional information is available on the Internet at:
http://www.siemens.com/ip65-hmi-devices
Note:
Do you require a specific modification to or option for the
products described here? Under "Customized products" you
can find information about additional and generally available
products for the sector, and about the possibilities for
customized modification and adaptation.
Stainless steel IP65 keyboard 15" 6AV7674-0NC00-0AA0
Width: 400 mm (adapted to
15" SIMATIC HMI PRO)
• Windows layout (EN/US)
without NUM block
Angle-adjustable adapter
Stainless steel IP65 keyboard 19" 6AV7674-0NE00-0AA0
Width: 483 mm (adapted to
19" SIMATIC HMI PRO)
• Windows layout (EN/US)
with NUM block
Angle-adjustable adapter
Tool and keyboard tray 6AV7674-0NE01-0AA0
Width: 483 mm (adapted to
19" SIMATIC HMI PRO)
Including 2-port USB interface
Angle-adjustable adapter
ST80_2013_EN_Kap03.book Seite 19 Mittwoch, 31. Juli 2013 3:24 15
© Siemens AG 2013
HMI devices for special requirements
Accessories for fully enclosed HMI devices
USB interfaces
3/20 Siemens ST 80 / ST PC · 2013
3
Overview
The USB interface is used for connecting external peripheral
devices to the MP 377 PRO, the HMI IPC477C PRO,
the Flat Panels PRO, and the Thin Client PRO.
USB peripheral devices can thus be connected and operated
without opening the device
Extension of the internal USB interface externally
Ordering data
Order No.
More information
Additional information is available on the Internet at:
http://www.siemens.com/ip65-hmi-devices
Note:
Do you require a specific modification to or option for the
products described here? Under "Customized products" you
can find information about additional and generally available
products for the sector, and about the possibilities for
customized modification and adaptation.
1-port USB interface 6AV7674-0LX00-0AA0
For fully enclosed HMI devices,
length USB cable: 0.5 m
2-port USB interface 6AV7674-0LX01-0AA0
For fully enclosed HMI devices,
length USB cable: 0.5 m.
Not suitable for: Thin Client,
MP 377, and Flat Panel
ST80_2013_EN_Kap03.book Seite 20 Mittwoch, 31. Juli 2013 3:24 15
© Siemens AG 2013
HMI devices for special requirements
Devices with stainless steel front
Devices with stainless steel front
3/21
Siemens ST 80 / ST PC · 2013
Overview
For special requirements, the following HMI devices with
stainless steel front (DIN EN 1672-2), e.g. for use in the food,
beverages and tobacco industries, are offered.
SIMATIC HMI IPC677C INOX
PC platform with high degree of industrial compatibility for
demanding tasks in the area of PC-based automation.
Rugged construction:
The PC is resistant to the harshest mechanical stress and is
reliable in operation.
Compact design
High degree of investment protection
Fast integration capability
15" TFT Touch, stainless steel/INOX
All interfaces such as PROFIBUS or PROFINET onboard
More SIMATIC HMI INOX panels
You will find further INOX industry products, as well as customer-
specific product variants, in the "Customized Automation"
section, e.g.
SIMATIC HMI Flat Panel 15" Touch INOX
SIMATIC HMI Flat Panel 19" Touch INOX
SIMATIC HMI Flat Panel 19" Touch INOX fully enclosed
Note:
Do you require a specific modification to or option for the
products described here? Then look up "Customized products",
where you will find information about additional generally-
available industry-specific products that can be ordered, as well
as about options for customer-specific modifications and
adaptations.
ST80_2013_EN_Kap03.book Seite 21 Mittwoch, 31. Juli 2013 3:24 15
© Siemens AG 2013
HMI devices for special requirements
Devices with stainless steel front
SIMATIC HMI IPC677C INOX
3/22 Siemens ST 80 / ST PC · 2013
3
Overview
PC platform with high degree of industrial compatibility for
demanding tasks in the area of PC-based automation.
Rugged design:
The PC is resistant to the harshest mechanical stress and is
reliable in operation.
Compact design
High degree of investment protection
Fast integration capability
Front panel versions:
- 15" TFT Touch, stainless steel/INOX
Technical specifications
HMI IPC677C INOX 15" Touch 6AV789...
General features
Front panel 15" TFT Touch
Display
Screen diagonal 15"
Resolution (W x H in pixels) 1024 x 768
MTBF of backlighting (at 25 °C) 50 000 h at 24 h continuous opera-
tion, temperature-dependent
Type of operation
Touch screen Yes
Design
Central design Yes
Dimensions
Installation cutout/device depth
(W x H x D) in mm 450 x 290 x 142 (incl. optical drive)
Mounting dimensions in centralized
configuration (W x H x D, without
optical drive) in mm
450 x 290 x 121
Additional mounting depth
(optical drive) in mm 21
Weight
HMI IPC in a centralized configuration
approx. 14 kg
ST80_2013_EN_Kap03.book Seite 22 Mittwoch, 31. Juli 2013 3:24 15
© Siemens AG 2013
HMI devices for special requirements
Devices with stainless steel front
SIMATIC HMI IPC677C INOX
3/23
Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
1)
Multi-language means: D/E/F/I/SP/CHIN traditional/CHIN simplified/
Korean/Japanese
2)
Without RAID 1 option only
SIMATIC HMI IPC677C INOX
6AV789 7-77777-7777
Front panels
15" TFT Touch 2
Front options
• INOX front, without front USB,
with 15" TFT Touch only 2
Power supply
24 V DC A
110/230 V AC,
power cable for Europe B
110/230 V AC, without power cable C
110/230 V AC, power cable for UK D
110/230 V AC, power cable for CH E
110/230 V AC,
power cable for the USA F
110/230 V AC,
power cable for Italy G
110/230 V AC,
power cable for China H
Processor
Intel Celeron 1.86 GHz
(2 MB shared cache), 2 cores A
Intel Celeron 1.86 GHz
(2 MB shared cache),
2 cores, PROFIBUS MPI,
2 MB buffered SRAM
B
Intel Celeron 1.86 GHz
(2 MB shared cache),
2 cores, PROFINET
(3x RJ45, CP1616-compatible),
2 MB buffered SRAM
C
• Intel Core i3, 2.13 GHz
(3 MB shared cache),
2 cores, hyper-threading
D
• Intel Core i3, 2.13 GHz
(3 MB shared cache), 2 cores,
hyper-threading, PROFIBUS MPI,
2 MB buffered SRAM
E
• Intel Core i3, 2.13 GHz
(3 MB shared cache), 2 cores,
hyper-threading, PROFINET
(3x RJ45, CP1616-compatible),
2 MB buffered SRAM
F
• Intel Core i7, 2.53 GHz
(4 MB shared cache), 2 cores,
hyper-threading, turbo boost
G
• Intel Core i7, 2.53 GHz
(4 MB shared cache),
2 cores, hyper-threading,
turbo boost, PROFIBUS MPI,
2 MB buffered SRAM
H
• Intel Core i7, 2.53 GHz
(4 MB shared cache), 2 cores,
hyper-threading, turbo boost,
PROFINET (3 x RJ45,
CP 1616-compatible),
2 MB buffered SRAM
J
SIMATIC HMI IPC677C INOX
(continued)
6AV789 7-7 7 7 7 7 -7 7 7 7
Main memory
• 1 GB DDR3 0
• 2 GB DDR3 1
• 3 GB DDR3 2
• 4 GB DDR3 3
• 8 GB DDR3 4
• 2 GB DDR3 with ECC 5
• 4 GB DDR3 with ECC 6
• 8 GB DDR3 with ECC 7
Mass storage
• 250 GB SATA hard disk 0
• 500 GB SATA hard disk 1
• RAID1 dual hard disk module
2 x 250 GB SATA, preconfigured 2
• Dual hard disk module
2 x 250 GB SATA 3
• 50 GB SSD (SLC) 4
• Second CF card slot
(only in combination with
Windows XP embedded),
internal, empty, only with version
without opt. drive and without HDD
5
• Without mass storage 8
Optical drives
• None 0
• DVD±RW±R combo drive 1
Communication Interfaces
• 2 x PCI available A
• 1 x PCI, 1 x PCIe (x16) available B
Operating system
(pre-installed and activated)
• Without operating system A
• Windows XP Professional
Multi-Language
1)
B
• Windows 7 Ultimate 32-bit
Multi-Language
1)
C
• Windows Embedded Standard
on 8 GB CF card
2)
D
• Windows 7 Ultimate 64-Bit
Multi-Language
1)
E
Software expansion
• None 0
• SIMATIC IPC DiagMonitor V4.3
enclosed 1
• SIMATIC IPC Image & Partition
Creator V3.2 enclosed 2
• SIMATIC IPC DiagMonitor V4.3,
Image & Partition Creator V3.2
enclosed
3
ST80_2013_EN_Kap03.book Seite 23 Mittwoch, 31. Juli 2013 3:24 15
© Siemens AG 2013
HMI devices for special requirements
Devices with stainless steel front
SIMATIC HMI IPC677C INOX
3/24 Siemens ST 80 / ST PC · 2013
Ordering data
Order No.
3
Accessories
Memory expansion
• 1 GB DDR3 DIMM 6ES7648-2AJ40-0KA0
• 2 GB DDR3 DIMM 6ES7648-2AJ50-0KA0
• 4 GB DDR3 DIMM 6ES7648-2AJ60-0KA0
• 1 GB DDR3 DIMM with ECC 6ES7648-2AJ40-1KA0
• 2 GB DDR3 DIMM with ECC 6ES7648-2AJ50-1KA0
• 4 GB DDR3 DIMM with ECC 6ES7648-2AJ60-1KA0
Non-heating apparatus cable for
SIMATIC Box and Panel PC
SIMATIC PC power cable,
230 V AC, angled, 3 m, for:
• Germany 6ES7900-1AA00-0XA0
• United Kingdom 6ES7900-1BA00-0XA0
• Switzerland 6ES7900-1CA00-0XA0
•USA 6ES7900-1DA00-0XA0
•Italy 6ES7900-1EA00-0XA0
• China 6ES7900-1FA00-0XA0
Touch pen 6AV7672-1JB00-0AA0
Captive pen for operation of the
touch devices, mounting of the
support on the control cabinet
Expansion components From page 5/153
Communication components From page 5/186
Dimensional drawings
All dimensions in mm.
Panel PC 677C INOX 15" Touch
More information
Additional information is available in the Internet under:
http://www.siemens.com/inox-hmi-devices
Note:
Do you require a specific modification or supplement to the
products described here? Then refer to "Customized products",
where you will find information about additional sector-specific
products that can be ordered as well as about options for
customer-specific modification and adaptation.
Control units
PC 677 INOX G H J K L M N
Touch devices
15" 289 271 138 11 24 367 42
K
K
L
M
N
G_ST80_XX_00288
G
H
J
ST80_2013_EN_Kap03.book Seite 24 Mittwoch, 31. Juli 2013 3:24 15
© Siemens AG 2013
HMI devices for special requirements
HMI devices for hazardous areas
HMI devices for hazardous areas
3/25
Siemens ST 80 / ST PC · 2013
Overview
The SIMATIC HMI Ex devices are intrinsically-safe Panel PCs
and Thin Clients which have been specially developed for
hazardous areas. The intrinsically-safe design allows simple
installation on site. The variety of certification allows use in many
parts of the world without further approvals.
The devices are fanless and permit completely maintenance-
free installation without batteries or rotating parts.
Available as HMI devices for hazardous areas "Zone 1" and
"Zone 2" are:
SIMATIC HMI Panel PC Ex
SIMATIC HMI Thin Client Ex
Further SIMATIC HMI devices are also available for the
hazardous area "Zone 2/22" and can be found in the chapter
"Operator panels":
SIMATIC HMI Comfort Panels
ST80_2013_EN_Kap03.book Seite 25 Mittwoch, 31. Juli 2013 3:24 15
© Siemens AG 2013
HMI devices for special requirements
HMI devices for hazardous areas
SIMATIC HMI Panel PC Ex
3/26 Siemens ST 80 / ST PC · 2013
3
Overview
SIMATIC HMI Panel PC Ex with international approvals for
operation and monitoring in hazardous areas.
Technical specifications
HMI Panel PC Ex 6AV7200-1...
General features
Design Panel PC built-in unit, protective
enclosure available as an option
Front 15" and 19", optional 15"
sunlight-readable displays
Operation Touch with 8 function keys
Processor Intel Atom N270 with 1.6 GHz
Main memory 1 GB DDR2 SDRAM, 2 GB optional
Operating system,
preinstalled and configured Windows XP Professional,
Windows XP Embedded,
Windows 7 MUI
Mass storage CompactFlash 4 GB / 16 GB,
hard disk 100 GB
Power supply 24 V DC, max. 2.1 A (19")
Interfaces
Ethernet 10/100 Mbit Ex e, or fiber-optics
100 Mbit (SC) Ex op is
USB 2.0 2 x Ex i, 2 x Ex e (Zone 1) or
2 x Ex nA (Zone 2)
Serial 1 x RS232 or 1 x RS422/485
Ambient conditions
Degree of protection IP66 at front, IP65 at rear,
IP66 in protective enclosure
Ambient temperature during operation -20 °C ... +50 °C (cold start -10 °C)
with optional additional heating
down to -30 °C
Relative humidity during operation 90 % at + 40 °C, no condensation
Approvals/directives
Devices in version "Zone 1"
ATEX directive 94/9/EC
• Network 10/100 Base-Tx II 2 (2) G Ex d e ia ib mb [ia ib] IIC
T4 Gb
II 2 (2) D Ex ia tb [ia ib] IIIC T80°C
Db IP66
• Network 10/100 Base-Fx II 2 (2) G Ex d e ia ib mb [ia ib op is]
IIC T4 Gb
II 2 (2) D Ex ia tb [ia ib op is] IIIC
T80°C Db IP66
IECEx
• Network 10/100 Base-Tx Ex d e ia ib mb [ia ib] IIC T4 Gb
Ex ia tb [ia ib] IIIC T80°C Db IP66
• Network 10/100 Base-Fx Ex d e ia ib mb [ia ib op is] IIC T4
Gb
Ex ia tb [ia ib op is] IIIC T80°C Db
IP66
GOST-R
• Network 10/100 Base-Tx 2 Ex d e ia ib mb [iaib] IIC T4
DIP A21 TA80°C, IP66
• Network 10/100 Base-Fx 2 Ex d e ia ib mb [iaibopis] IIC T4
DIP A21 TA80°C, IP66
CSA Ex d e ia ib mb [ia ib] IIC T4 Gb,
Type 4X, IP66
Class II, Division 1, Groups E, F, G,
T80°C
Ex ia tb [ia ib] IIIC T80°C Db, IP66
KGS Ex d e ia ib mb [ia ib] IIC T4
Ex ia tb [ia ib] IIIC T80°C Db IP66
InMetro
• Network 10/100 Base-Tx Ex d e ia ib mb [ia ib] IIC T4 Gb
Ex ia tb [ia ib] IIIC T80°C Db IP66
• Network 10/100 Base-Fx Ex d e ia ib mb [ia ib op is] IIC T4
Gb
Ex ia tb [ia ib op is] IIIC T80°C Db
IP66
Device version "UL Class 1,
Division 2" Class 1, Division 2,
Groups A, B, C, D
Class 2, Division 2, Groups F, G
Class 3, Hazardous Locations
HMI Panel PC Ex 6AV7200-1...
ST80_2013_EN_Kap03.book Seite 26 Mittwoch, 31. Juli 2013 3:24 15
© Siemens AG 2013
HMI devices for special requirements
HMI devices for hazardous areas
SIMATIC HMI Panel PC Ex
3/27
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
Devices in version "Zone 2"
ATEX directive 94/9/EC
• Network 10/100 Base-Tx II 3 (2/3) G Ex d e ia ib mb nA
[ib Gb] [ic] IIC T4 Gc
II3 (2/3) D Ex ia tc [ib Db] [ic] IIIC
T80°C Dc IP66
• Network 10/100 Base-Fx II 3 (2/3) G Ex d e ia ib mb nA
[ib op is Gb] [ic] IIC T4 Gc
II 3 (2/3) D Ex ia tc [ib op is Db]
[ic] IIIC T80°C Dc IP66
IECEx
• Network 10/100 Base-Tx Ex d e ia ib mb nA [ib Gb] [ic]
IIC T4 Gc
Ex ia tc [ib Db] [ic] IIIC T80°C Dc
IP66
• Network 10/100 Base-Fx Ex d e ia ib mb nA [ib op is Gb
] [ic] IIC T4 Gc
Ex ia tc [ib op is Db] [ic] IIIC T80°C
Dc IP66
GOST-R
• Network 10/100 Base-Tx 2 Ex d e ia ib mb nA [ib][ic] IIC T4
DIP A21 TA80°C, IP66
• Network 10/100 Base-Fx 2 Ex d e ia ib mb nA [ib opis][ic] IIC
T4
DIP A21 TA80°C, IP66
CSA Ex d e ia ib mb nA [ib Gb] [ic] IIC T4
Gc, Type 4X, IP66
Class II, Division 2, Groups E, F, G,
T80°C;
Ex ia tc [ib ic] IIIC T80°C Dc, IP66
InMetro
• Network 10/100 Base-Tx Ex d e ia ib mb nA [ib Gb] [ic] IIC T4
Gc
Ex ia tc [ib Db] [ic] IIIC T80°C Dc
IP66
• Network 10/100 Base-Fx Ex d e ia ib mb nA [ib op is Gb] IIC
T4
Ex ia tc [ib op is Db] [ic] IIIC T80°C
Dc IP66
Device version "UL Class 1,
Division 2" Class 1, Division 2,
Groups A, B, C, D
Class 2, Division 2, Groups F, G
Class 3, Hazardous Locations
HMI Panel PC Ex 6AV7200-1...
Dimensions
Mounting dimensions (W x H x D) 15":
427.5 mm x 327.5 mm x 165 mm
19":
522.5 mm x 412.5 mm x 165 mm
Front dimensions (W x H) 15": 440 mm x 340 mm
19": 535 mm x 425 mm
Weight 15": 15 kg
19": 23 kg
HMI Panel PC Ex 6AV7200-1...
ST80_2013_EN_Kap03.book Seite 27 Mittwoch, 31. Juli 2013 3:24 15
© Siemens AG 2013
HMI devices for special requirements
HMI devices for hazardous areas
SIMATIC HMI Panel PC Ex
3/28 Siemens ST 80 / ST PC · 2013
3
Ordering data
Order No. Order No.
1)
Package 1: upon initial startup, select the language from: English, German,
French, Italian, Spanish, Portuguese, Brazilian, Dutch, Danish, Swedish,
Norwegian, Finnish, Greek, Hungarian, Czech, Polish, Turkish, Russian,
Hebrew, Arabic, Chinese, Japanese, Korean, Thai
SIMATIC HMI Panel PC Ex 6AV7200-
17777-7 7 A 0
Design / display size
Zone 2: 15" Touch
with function keys A
Zone 2: 19" Touch
with function keys B
Zone 1: 15" Touch
with function keys D
Zone 1: 19" Touch
with function keys E
UL Class 1, Division 2:
15" Touch with function keys G
UL Class 1, Division 2:
19" Touch with function keys H
Zone 2: 15" Touch, sunlight
readable with 8 function keys J
Zone 1: 15" Touch, sunlight
readable with 8 function keys K
Communication interfaces
• 10/100 base Tx, Ex e A
100 base Fx FOC (SC), Ex op is B
Mass storage
CF 4 GB, 1 GB RAM 1
CF 16 GB, 1 GB RAM 2
HDD 100 GB, 1 GB RAM 3
CF 4 GB, 2 GB RAM 4
CF 16 GB, 2 GB RAM 5
HDD 100 GB, 2 GB RAM 6
Operating system (preinstalled)
• Windows XP Embedded on CF
(language package 1)
1)
1
• Windows XP Professional MUI
(only on HDD) 3
Windows 7 Ultimate (only on HDD) 4
Enclosure options
(device is delivered already fitted)
• without 0
• Stainless steel enclosure for:
- Wall mounting 2
- Stand (incl. coupling,
300° rotation possible) 3
- Suspension bracket (incl.
coupling, 300° rotation possible) 4
- Support arm (incl. coupling,
300° rotation possible) 5
- Swivel arm from above (incl.
coupling, 300° rotation possible) 6
External keyboard for stainless steel
enclosure (incl. keyboard enclosure)
• without A
• QWERTZ keyboard B
• QWERTY keyboard C
AZERTY keyboard D
• QWERTZ keyboard with trackball E
• QWERTY keyboard with trackball F
AZERTY keyboard with trackball G
Further options together with
stainless steel enclosure
Breather glands -z A 0 1
Heating (requires breather glands) -z B 0 1
• Handles -z C 0 1
Front USB (at bottom) -z D 0 1
Accessories
Digital KVM for HMI Thin Client Ex 6AV7675-0EX00-0AA0
USB drive
• Intrinsically-safe, 8 GB 6AV7675-0FX00-0AA0
• Intrinsically-safe,
8 GB with recovery function 6AV7675-0FX10-0AA0
Ethernet switch 6AV7675-0PX00-0AA0
with FOC 4 x 100 Base Tx,
1 x 100 Base (MTRJ) Fx Ex op is
ST80_2013_EN_Kap03.book Seite 28 Mittwoch, 31. Juli 2013 3:24 15
© Siemens AG 2013
HMI devices for special requirements
HMI devices for hazardous areas
SIMATIC HMI Panel PC Ex
3/29
Siemens ST 80 / ST PC · 2013
Dimensional drawings
Legend:
h = Mounting clamp (10 x)
i = Clamping frame
j = Control cabinet or enclosure
All dimensions in mm. For mounting cut-out see technical specifications.
SIMATIC HMI Panel PC Ex 15"
SIMATIC HMI Panel PC Ex 19"
More information
Additional information is available on the Internet at:
http://www.siemens.com/simatic-hmi-ex
327.5+0.5
427.5+0.5
G_ST80_XX_00419
165
326
340
440
426
j
i
h
412.5+0.5
522.5+0.5
G_ST80_XX_00420
165
411
425
535
521
j
i
h
ST80_2013_EN_Kap03.book Seite 29 Mittwoch, 31. Juli 2013 3:24 15
© Siemens AG 2013
HMI devices for special requirements
HMI devices for hazardous areas
SIMATIC HMI Thin Client Ex
3/30 Siemens ST 80 / ST PC · 2013
3
Overview
SIMATIC HMI Thin Client Ex with international approvals for
operation and monitoring in hazardous areas.
Technical specifications
HMI Thin Client Ex 6AV7200-0...
General features
Design Thin Client built-in unit, available in
protective enclosure as an option
Front 15", 19", and 15" sunlight readable
display
Operation Touch with 8 function keys
MTBF backlight 50 000 h
Operating system Closed system on Windows XP
Embedded basis
Mass storage Integrated
Power supply 24 V DC, max. 2.1 A (19")
Interfaces
Ethernet 100 Mbit Ex e, or alternatively
fiber-optics 100 Mbit (SC) Ex op is
USB 2.0 2 x Ex i, 2 x Ex e (Zone 1) or
2 x Ex nA (Zone 2)
Serial 1 x RS232 or 1 x RS422/485
Ambient conditions
Degree of protection IP66 at front, IP65 at rear, IP66 in
protective enclosure
Ambient temperature during operation - 20 °C ... + 50 °C, cold start -10 °C,
with optional additional heating
down to -30 °C
Relative humidity during operation 90 % at 40 °C, no condensation
Approvals/directives
Devices in "Zone 1" version
ATEX directive 94/9/EC
• Network 10/100 Base-Tx II 2 (2) G Ex d e ia ib mb [ia ib] IIC
T4 Gb
II 2 (2) D Ex ia tb [ia ib] IIIC T80°C
Db IP66
• Network 10/100 Base-Fx II 2 (2) G Ex d e ia ib mb [ia ib op is]
IIC T4 Gb
II 2 (2) D Ex ia tb [ia ib op is] IIIC
T80°C Db IP66
IECEx
• Network 10/100 Base-Tx Ex d e ia ib mb [ia ib] IIC T4 Gb
Ex ia tb [ia ib] IIIC T80°C Db IP66
• Network 10/100 Base-Fx Ex d e ia ib mb [ia ib op is] IIC T4
Gb
Ex ia tb [ia ib op is] IIIC T80°C Db
IP66
GOST-R
• Network 10/100 Base-Tx 2 Ex d e ia ib mb [iaib] IIC T4
DIP A21 TA80°C, IP66
• Network 10/100 Base-Fx 2 Ex d e ia ib mb [iaibopis] IIC T4
DIP A21 TA80°C, IP66
CSA Ex d e ia ib mb [ia ib] IIC T4 Gb,
Type 4X, IP66
Class II, Division 1, Groups E, F, G,
T80°C
Ex ia tb [ia ib] IIIC T80°C Db, IP66
KGS Ex d e ia ib mb [ia ib] IIC T4
Ex ia tb [ia ib] IIIC T80°C Db IP66
InMetro
• Network 10/100 Base-Tx Ex d e ia ib mb [ia ib] IIC T4 Gb
Ex ia tb [ia ib] IIIC T80°C Db IP66
• Network 10/100 Base-Fx Ex d e ia ib mb [ia ib op is] IIC T4
Gb
Ex ia tb [ia ib op is] IIIC T80°C Db
IP66
Devices in version "Zone 2"
ATEX directive 94/9/EC
• Network 10/100 Base-Tx II 3 (2/3) G Ex d e ia ib mb nA [ib
Gb] [ic] IIC T4 Gc
II3 (2/3) D Ex ia tc [ib Db] [ic] IIIC
T80°C Dc IP66
• Network 10/100 Base-Fx II 3 (2/3) G Ex d e ia ib mb nA [ib op
is Gb] [ic] IIC T4 Gc
II 3 (2/3) D Ex ia tc [ib op is Db] [ic]
IIIC T80°C Dc IP66
IECEx
• Network 10/100 Base-Tx Ex d e ia ib mb nA [ib Gb] [ic] IIC T4
Gc
Ex ia tc [ib Db] [ic] IIIC T80°C Dc
IP66
• Network 10/100 Base-Fx Ex d e ia ib mb nA [ib op is Gb] [ic]
IIC T4 Gc
Ex ia tc [ib op is Db] [ic] IIIC T80°C
Dc IP66
GOST-R
• Network 10/100 Base-Tx 2 Ex de i a ib mb nA [ib][ic] IIC T4
DIP A21 TA80°C, IP66
• Network 10/100 Base-Fx 2 Ex de i a ib mb nA [ibopis][ic] IIC
T4
DIP A21 TA80°C, IP66
CSA Ex d e ia ib mb nA [ib Gb] [ic] IIC T4
Gc, Type 4X, IP66
Class II, Division 2, Groups E, F, G,
T80°C; Ex ia tc [ib ic] IIIC
T80°C Dc, IP66
InMetro
• Network 10/100 Base-Tx Ex d e ia ib mb nA [ib Gb] [ic] IIC T4
Gc
Ex ia tc [ib Db] [ic] IIIC T80°C Dc
IP66
• Network 10/100 Base-Fx Ex d e ia ib mb nA [ib op is Gb] IIC
T4
Ex ia tc [ib op is Db] [ic] IIIC T80°C
Dc IP66
Protocols RDP, RealVNC
Digital KVM switch Input: DVI / VGA, PS/2 / USB,
output: RJ45 (IP network)
Dimensions
Mounting dimensions
(W x H x D) in mm 15": 427.5 x 327.5 x 165
19": 522.5 x 412.5 x 165
Front dimensions in mm 15": 440 x 340
19": 535 x 425
Weight 15": 15 kg, 19": 23 kg
HMI Thin Client Ex 6AV7200-0...
ST80_2013_EN_Kap03.book Seite 30 Mittwoch, 31. Juli 2013 3:24 15
© Siemens AG 2013
HMI devices for special requirements
HMI devices for hazardous areas
SIMATIC HMI Thin Client Ex
3/31
Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
SIMATIC HMI Thin Client Ex 6AV7200-
07 7 0 0 - 7 7
A
0
Design / display size
Zone 2: 15" Touch
with function keys A
Zone 2: 19" Touch
with function keys B
Zone 1: 15" Touch
with function keys D
Zone 1: 19" Touch
with function keys E
Zone 2: 15" Touch, sunlight
readable with function keys G
Zone 1: 15" Touch, sunlight
• readable with function keys H
Communication interfaces
• 10/100 base Tx, Ex e A
100 base Fx FOC (SC), Ex op is B
Enclosure options
(device is delivered already fitted)
• without 0
• Stainless steel enclosure for:
- Wall mounting 2
- Stand (incl. coupling,
300° rotation possible) 3
- Suspension bracket (incl.
coupling, 300° rotation possible) 4
- Support arm (incl. coupling,
300° rotation possible) 5
- Swivel arm from above (incl.
coupling, 300° rotation possible) 6
External keyboard for enclosure
(incl. keyboard enclosure)
• without A
• QWERTZ keyboard B
• QWERTY keyboard C
AZERTY keyboard D
• QWERTZ keyboard with trackball E
• QWERTY keyboard with trackball F
AZERTY keyboard with trackball G
Further options together with
stainless steel enclosure
Breather glands -z A 0 1
Heating (requires breather glands) -z B 0 1
• Handles -z C 0 1
Front USB (at bottom) -z D 0 1
Accessories
Digital KVM for HMI Thin Client Ex 6AV7675-0EX00-0AA0
USB drive
• Intrinsically-safe, 8 GB 6AV7675-0FX00-0AA0
• Intrinsically-safe,
8 GB with recovery function 6AV7675-0FX10-0AA0
Ethernet switch 6AV7675-0PX00-0AA0
With FOC 4 x 100 Base Tx,
1 x 100 Base (MTRJ) Fx Ex op is
ST80_2013_EN_Kap03.book Seite 31 Mittwoch, 31. Juli 2013 3:24 15
© Siemens AG 2013
HMI devices for special requirements
HMI devices for hazardous areas
SIMATIC HMI Thin Client Ex
3/32 Siemens ST 80 / ST PC · 2013
3
Dimensional drawings
Legend:
h = Mounting clamp (10 x)
i = Clamping frame
j = Control cabinet or enclosure
All dimensions in mm. For mounting cut-out see technical specifications.
SIMATIC HMI Thin Client Ex 15"
SIMATIC HMI Thin Client Ex 19"
More information
Additional information is available on the Internet at:
http://www.siemens.com/simatic-hmi-ex
327.5+0.5
427.5+0.5
G_ST80_XX_00419
165
326
340
440
426
j
i
h
15" touch front Width in mm Height in mm Depth in mm
Operating unit 440 340 165
Installation cutout 427.5 ± 0.5 327.5 ± 0.5 -
412.5+0.5
522.5+0.5
G_ST80_XX_00420
165
411
425
535
521
j
i
h
19" touch front Width in mm Height in mm Depth in mm
Operating unit 535 425 165
Installation cutout 522 ± 0.5 412.5 ± 0.5 -
ST80_2013_EN_Kap03.book Seite 32 Mittwoch, 31. Juli 2013 3:24 15
© Siemens AG 2013
Siemens ST 80 / ST PC · 2013
4
HMI Software
4/2 Introduction
4/5 HMI Software in the TIA Portal
4/6 SIMATIC WinCC (TIA Portal)
Engineering
4/12 SIMATIC WinCC (TIA Portal) Runtime
4/14 WinCC Runtime Advanced
4/19 WinCC Runtime Professional
4/25 WinCC Runtime Communication
4/31 SIMATIC WinCC (TIA Portal) options
4/32 WinCC Recipes
4/34 WinCC Logging
4/36 WinCC Audit
4/37 SIMATIC Logon
4/38 WinCC Sm@rtServer
4/42 WinCC Server / WinCC Client
4/44 WinCC WebNavigator
4/47 WinCC DataMonitor
4/50 WinCC ControlDevelopment
4/51 Software for energy management
4/52 SIMATIC B.Data
4/56 SIMATIC powerrate
4/59 SIMATIC WinCC flexible
HMI system
4/60 SIMATIC WinCC flexible ES
4/64 SIMATIC WinCC flexible RT
4/71 SIMATIC WinCC flexible options
4/72 WinCC flexible /ChangeControl
4/73 WinCC flexible /Archives
4/74 WinCC flexible /Recipes
4/75 WinCC flexible /Audit
4/76 SIMATIC Logon for WinCC flexible
4/78 WinCC flexible /Sm@rtAccess
4/82 WinCC flexible /Sm@rtService
4/85 WinCC flexible /OPC server
4/87 WinCC flexible /ProAgent
4/88 SCADA system SIMATIC WinCC
4/89 SIMATIC WinCC
4/107 SIMATIC WinCC options
4/108 SIMATIC BATCH for WinCC
4/110 SIMATIC Information Server
4/111 SIMATIC Logon
4/112 SIMATIC Maintenance Station
4/115 SIMATIC Process Historian
4/116 WinCC/Calendar Scheduler
4/117 WinCC/Central Archive Server (CAS)
4/118 WinCC/ChangeControl & WinCC/Audit
4/120 WinCC/Connectivity Pack &
WinCC Connectivity Station
4/122 WinCC/DataMonitor
4/124 WinCC/DowntimeMonitor
4/126 WinCC/Event Notifier
4/127 WinCC/IndustrialDataBridge
4/129 WinCC/IndustrialX
4/130 WinCC/Open Development Kit (ODK)
4/131 WinCC/ProAgent
4/132 WinCC/Redundancy
4/133 WinCC/Server
4/134 WinCC/TeleControl
4/138 WinCC/User Archives
4/139 WinCC/Web Navigator
4/144 WinCC add-ons and
partner management
4/146 SCADA System
SIMATIC WinCC Open Architecture
4/155 SIMATIC WinCC Open Architecture
Add-ons
4/161 SIMATIC ProAgent process
diagnostics software
ST80_2013_EN_Kap04.book Seite 1 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
Introduction
HMI software
4/2 Siemens ST 80 / ST PC · 2013
4
Overview
With the product families SIMATIC WinCC (TIA Portal),
SIMATIC WinCC flexible, SIMATIC WinCC and SIMATIC WinCC
Open Architecture, SIMATIC HMI offers visualization and config-
uration software for the entire HMI spectrum:
SIMATIC WinCC (TIA Portal)
Creation of applications in the machine-level area and of
process visualization or SCADA systems
SIMATIC WinCC flexible
Creation of applications in the machine-level area:
SIMATIC WinCC
Creation of process visualization or SCADA systems
SIMATIC WinCC Open Architecture
Creation of applications with a high demand for customer-
specific adaptations, large and/or complex applications, as
well as projects that demand special system requirements
and functions.
SIMATIC WinCC (TIA Portal)
WinCC (TIA Portal) is based on the new central engineering
framework Totally Integrated Automation Portal (TIA Portal),
which provides users with an integrated, efficient and intuitive
solution to all automation tasks. SIMATIC WinCC (TIA Portal)
covers applications in the machine-level area and applications
in the process visualization or SCADA environment. WinCC
(TIA Portal) offers the uniform and scalable configuration tools
WinCC Basic, Comfort, Advanced and Professional for config-
uring the current SIMATIC HMI devices:
SIMATIC Basic Panels
SIMATIC Comfort Panels
SIMATIC Mobile Panels
SIMATIC Panels 77/177/277 series
SIMATIC Multi Panels of the 177/277/377 series
PC-based systems
- SIMATIC WinCC Runtime Advanced
- SIMATIC WinCC Runtime Professional
In addition, WinCC (TIA Portal) offers:
Intuitive user interface with maximum degree of operator
friendliness
Clear configuration of devices and network topologies
Shared data management and uniform symbols via controller
and HMI
Optimum interaction with the controller and HMI in a working
environment
Powerful editors for efficient engineering
Integrated mass data operations for efficient configuration
System diagnostics as an integral component
Comprehensive library concept
Integrated runtime
module
PC-based
single-user system,
e.g. SIMATIC IPC
Comfort Panels
Mobile Panels
x77 Panels and
Multi Panels
Runtime Software
and target systems
Integrated runtime
module
PC-based multi-user system
SCADA functionality
Engineering
Software
G_ST80_XX_00461
WinCC Basic
WinCC Comfort
WinCC Advanced
WinCC Professional
WinCC Runtime Professional
Basic Panels
WinCC Runtime
Advanced
ST80_2013_EN_Kap04.book Seite 2 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
Introduction
HMI software
4/3
Siemens ST 80 / ST PC · 2013
Overview (continued)
SIMATIC WinCC flexible
Covers applications in the machine-level area. WinCC flexible
offers the integrated and scalable configuration tools
WinCC flexible Micro, Compact, Standard and Advanced for
configuring SIMATIC HMI devices:
SIMATIC Basic Panels
SIMATIC Mobile Panels
SIMATIC Micro Panels
SIMATIC Panels of the 70/170/270 series as well as C7-635
and C7-636
SIMATIC Multi Panels of the 170/270/370 series
PC-based systems
- SIMATIC WinCC flexible Runtime
Runs under Windows XP Professional /
Windows 7 Professional, Ultimate, Enterprise
Expanded integration into STEP 7 and SIMOTION
Optionally expandable with functions for version adminis-
tration and logging changes (WinCC flexible /ChangeControl)
Modular PC-based HMI solution for single-user systems
directly at the machine level
Basic package for visualization, reporting and logging; can be
expanded by implementing option packages
Flexible expansion possible with VB scripts and customized
ActiveX controls created with OPP (Open Platform Program)
SIMATIC WinCC
The process visualization or SCADA system for visualizing and
operating processes, production flows, machines and plants in
all sectors – from the simple single-user station through to
distributed multi-user systems with redundant servers and
cross-location solutions with web clients. WinCC is the infor-
mation hub for company-wide, vertical integration (process
visualization and platform for IT & business integration).
For universal use thanks to solutions for all sectors, e.g.
conforming to FDA 21 CFR Part 11, and multiple languages for
worldwide use
All HMI functions on-board with industry-standard functions
for signaling and acknowledging events, archiving of
messages and measured values, logging of all process and
configuration data, user administration and visualization
(WinCC basic software).
Company-wide, flexible client/server structures with operator
stations on the Web, distributed servers and data integrity
thanks to redundancy
Easy to integrate over standard interfaces such as
OPC (OLE for Process Control), WinCC OLE-DB,
VBA (Visual Basic for Applications), VB script, C-API (ODK)
Integration platform in the company thanks to the Historian
functionality integrated into WinCC based on the Microsoft
SQL Server, standard and programming interfaces and tools
and clients for evaluation
Modular expansion with options and add-ons as well as
individual functional expansions with VB Script, Visual Basic
for Applications, C-API (ODK) and integration of ActiveX
elements.
Object-orientation supports efficient engineering and flexible
plant expansion
For large, distributed systems with up to 2048 servers
Scalable – from a small single-user system up to a networked,
redundant high-end system
WinCC OA can be used on any platform and is available for
Windows, Linux and Solaris
Hot-standby redundancy and disaster recovery system
assure maximum fail-safety and availability
WinCC OA offers a platform for customer-specific solutions
Extensive driver and interfacing options: S7, SINAUT, OPC,
OPC UA, Modbus, IEC 60870-5-101/104, DNP3, BACnet, and
many others.
Flexible logging of data either in file-based value archive or in
a relational database (ORACLE)
Modular expansion is possible using options and add-ons as
well as individual functional expansions by means of own
script language CONTROL, API(C++) and integration of
ActiveX elements
ST80_2013_EN_Kap04.book Seite 3 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
Introduction
HMI software
4/4 Siemens ST 80 / ST PC · 2013
Overview (continued)
4
SIMATIC WinCC Open Architecture
The SCADA system SIMATIC WinCC Open Architecture
addresses applications with high demand for customer-specific
adaptations, large and/or complex applications, as well as
projects that demand special system requirements and
functions.
SIMATIC WinCC Open Architecture demonstrates its high
performance in networked and redundant high-end control
systems in particular. From the field level to the control station,
from the machine to the company headquarters – integrated,
high-performance communication is ensured. In every situation,
a high level of availability, reliable information, fast interaction
and user friendliness are guaranteed. Applications can also be
changed without interrupting the process. Profitability, efficiency
and safety are therefore always in equilibrium.
With its disaster recovery system and SIL3 certification, SIMATIC
WinCC Open Architecture demonstrates its reliability in a wide
range of critical applications.
SIMATIC WinCC Open Architecture is open for independent in-
house developments, which means that ideas can be turned into
new applications quickly and easily.
Object-orientation supports efficient engineering and flexible
plant expansion
For large, distributed systems with up to 2048 servers
Scalable – from a small single-user system up to a networked,
redundant high-end system
WinCC OA can be used on any platform and is available for
Windows, Linux and Solaris
Hot-standby redundancy and disaster recovery system
assure maximum fail-safety and availability
WinCC OA offers a platform for customer-specific solutions
Extensive driver and interfacing options: S7, SINAUT, OPC,
OPC UA, Modbus, IEC 60870-5-101/104, DNP3, BACnet, and
many others.
Flexible logging of data either in file-based value archive or in
a relational database (ORACLE)
Modular expansion is possible using options and add-ons as
well as individual functional expansions by means of own
script language CONTROL, API(C++) and integration of
ActiveX elements
ST80_2013_EN_Kap04.book Seite 4 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
HMI Software in the TIA Portal
HMI Software in the TIA Portal
4/5
Siemens ST 80 / ST PC · 2013
Overview
SIMATIC WinCC (TIA Portal) engineering software
Family of configuration systems with WinCC Basic, Comfort,
Advanced and Professional for SIMATIC operator panels, as
well as for the PC-based visualization systems WinCC
Runtime Advanced and WinCC Runtime Professional
SIMATIC WinCC Runtime Advanced visualization software
PC-based HMI solution for single-user systems directly at the
machine
Basic package for visualization, reporting and logging, user
administration, can be expanded flexibly with VB scripts
Basic package expandable by means of option packages
Integration of customer-specific ActiveX Controls created with
WinCC ControlDevelopment
Can be integrated into automation solutions based on TCP/IP
networks
Expanded service concepts with remote operation,
diagnostics and administration over the Intranet and Internet
in combination with e-mail communication
SIMATIC WinCC Runtime Professional visualization
software
PC-based operator control and monitoring system for visual-
ization and operator control of processes, production flows,
machines and plants in all sectors – from the simple single-
user station through to distributed multi-user systems and
cross-location solutions with web clients. WinCC Runtime
Professional is the information hub for corporation-wide
vertical integration.
Industry-standard functions for signaling and acknowledging
events, archiving of messages and measured values, logging
of all process and configuration data, user administration, can
be expanded flexibly with VB and C scripts
Basic package expandable by means of option packages
Also included are APIs for the Runtime to utilize the open
programming interfaces
Integration of customer-specific ActiveX Controls created with
WinCC ControlDevelopment
ST80_2013_EN_Kap04.book Seite 5 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Engineering
4/6 Siemens ST 80 / ST PC · 2013
4
Overview
Integrated family of engineering tools for configuring
SIMATIC HMI operator panels, as well as for the PC-based
visualization systems WinCC Runtime Advanced and
WinCC Runtime Professional.
WinCC (TIA Portal) is based on the new central engineering
framework Totally Integrated Automation Portal (TIA Portal),
which offers the user a uniform, efficient and intuitive solution
to all automation tasks.
WinCC (TIA Portal) also offers uniform engineering from the
Basic Panel through to the SCADA application.
Together with the STEP 7 (TIA Portal) products, WinCC
(TIA Portal) forms the optimum solution for integrated, efficient
engineering.
Current version:
SIMATIC WinCC Basic V12 SP1
SIMATIC WinCC Comfort V12 SP1
SIMATIC WinCC Advanced V12 SP1
SIMATIC WinCC Professional V12 SP1
Benefits
The integrated configuration software reduces training,
maintenance and service overhead and protects the
customer's investments.
Minimized engineering overhead and reduction of lifecycle
costs thanks to Totally Integrated Automation (TIA)
Minimized configuration overhead due to reuse of scalable
and dynamizable objects
Intelligent tools for efficient and simple configuration:
- Wizard for defining the basic structure of the HMI project
- Table-based editors simplify the generation and processing
of similar types of object, e.g. for tags, texts, or alarms.
- Complex configuration tasks such as the definition of paths
of motion or the creation of the fundamental operator
prompting are simplified by means of graphical configu-
ration.
Comprehensive support of multi-language configurations for
worldwide use
- Selectable views for entering configuration data in several
languages
- System and user-specific text lexicons
- Export/import of language-dependent texts
Investment protection due to
- Import of the configuration from WinCC flexible 2008 SP2
and 2008 SP3
- Transfer of the configuration from WinCC V7.0 SP3
Application
SIMATIC WinCC in the editions Basic, Comfort, Advanced and
Professional are innovative engineering tools for configuring
SIMATIC HMI operator panels, as well as for the PC-based
visualization systems WinCC Runtime Advanced and WinCC
Runtime Professional.
Depending on the selected product, various target systems can
be configured:
WinCC Basic
Basic Panels
WinCC Comfort
As WinCC Basic, plus:
Comfort Panels
Mobile Panels: Mobile Panel 177, Mobile Panel 277
Panels of the 70 series: OP 73, OP 77A, OP 77B
Panels of the 170 series: TP 177A, TP 177B, OP 177B
Panels of the 270 series: TP 277, OP 277
Multi Panels: MP 177, MP 277, MP 377
WinCC Advanced
As WinCC Comfort, plus:
SIMATIC PCs with WinCC Runtime Advanced:
- SIMATIC Panel PC: IPC277D, Panel PC 477B, IPC477C,
IPC477D, Panel PC 577B, IPC577C, Panel PC 677B,
IPC677C
- SIMATIC Box PC: IPC227D, Box PC 427B, IPC427C,
IPC427D, Box PC 627B, IPC627C, Box PC 827B, IPC827C
- SIMATIC Rack PC: Rack PC 547B, IPC547C, IPC547D,
Rack PC 647B, IPC647C, Rack PC 847B, IPC847C
- SIMATIC modular Embedded Controller: EC31
Standard PC with WinCC Runtime Advanced
SINUMERIK PC: PCU 50.3, PCU 50.5
WinCC Professional
As WinCC Advanced, plus:
SIMATIC PCs with WinCC Runtime Professional:
- SIMATIC Panel PC: IPC477C, IPC477D, Panel PC 577B,
IPC577C, Panel PC 677B, IPC677C,
- SIMATIC Box PC: IPC427C, IPC427D, Box PC 627B,
IPC627C, IPC827C
- SIMATIC Rack PC: Rack PC 547B, IPC547C, IPC547D,
Rack PC 647B, IPC647C, Rack PC 847B, IPC847C
Standard PC with WinCC Runtime Professional
ST80_2013_EN_Kap04.book Seite 6 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Engineering
4/7
Siemens ST 80 / ST PC · 2013
Design
The functionalities of the engineering tools of the SIMATIC
WinCC family are based on each other. The available editors are
largely determined by the respective configurable target
systems and their function. A more comprehensive engineering
tool such as WinCC Advanced can always be used to configure
lower-level target devices as well (e.g. Basic Panels)
A Powerpack can be used to upgrade from a smaller edition to
a larger one. This does not apply to WinCC Basic.
The functionality of WinCC engineering tools already contains
the configuration support of the available Runtime options for
SIMATIC Panels, WinCC Runtime Advanced or WinCC Runtime
Professional, irrespective of the purchased RT licenses.
A separate license is required for the target system when using
the configured Runtime options.
Function
Integration into automation systems
Integration into the SIMATIC Totally Integrated Automation Portal
(TIA Portal)
Shared data management and uniform symbols via the
controller and HMI
Optimum interaction between the controller and HMI in a
working environment
System diagnostics as an integral component
Shared use of communication settings and process point
definitions
Simple dragging and dropping of tags from STEP 7 to an
HMI device, e.g. onto a screen
Excellent support for the new SIMATIC S7-1500 controller
- With symbolic addressing
- Access to the new memory-optimized data blocks
- New alarm and diagnostics concept
Configuration interface
Intuitive user interfaces with maximum degree of
user friendliness
Comprehensive and fast access to editors and project data
Adaptive user interface of engineering tools depending on
configured target system
User-definable user interface settings, e.g. layout, toolbars
Integrated mass data operations for efficient configuration
Project handling
Device-independent configuration data can be used on a
variety of target systems without the need for conversion.
The interface adapts itself to the functional possibilities of the
target device.
Cross-device utilization of common configuration data
(e.g. alarm classes, text library) in multi-device projects
Wizard-assisted definition of basic structure of HMI projects
(e.g. display layout, operator prompting)
Screen editor with comprehensive options for efficient and
fast screen configuration
Generation of interconnected screen objects via Drag&Drop,
e.g. tags for the creation of input/output fields with process
interfacing or buttons with screen selection function
Definition of screen templates and functions
(comparable with the Slide Master in MS PowerPoint)
User-friendly editor for the creation of faceplates with defined
external interface from screen objects
Graphics-based configuration of motion paths
Layer technology with up to 32 layers
Tools for the Align, Rotate and Mirror functions
Import/export
of tags, links, text lists, and alarms
Tabular editors
Quick and easy generation and modification of configuration
objects of the same type, e.g. tags, texts or messages, in
tabular editors
Intelligent default settings depending on previously
configured data, e.g. automatic incrementing of addresses
when generating consecutive tags
Simple access to the properties of an object without super-
fluous user intervention
Simultaneous modification of common object properties
Object-based data management with user-friendly search
and edit options
Configuration of alarms and logs directly on the HMI tag,
no switching between different editors
Cross-reference list with direct access to all objects,
e.g. for editing or selection
Search for objects in entire project
Text search and replace functions
Project documentation
Selective project documentation, the following contents can
be printed:
- An entire project
- One or more project-associated devices
- Contents of an editor
- Libraries
ST80_2013_EN_Kap04.book Seite 7 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Engineering
4/8 Siemens ST 80 / ST PC · 2013
Function (continued)
4
Libraries for predefined/user-defined configuration objects
Storage of all configuration objects in the library, e.g. blocks
and even entire screens or tags
Faceplates can be constructed from simple screen objects on
a customer-specific or project-specific basis. Changes to
these faceplates can be made centrally (block definition).
A large number of scalable and dynamizable screen objects
is included in the scope of delivery
Size-scalable graphics for industrial applications are included
in the scope of delivery
Preview function for library objects
Language support
Multilingual project creation (max. 32 languages) in editors
thanks to selectable views
Central management of language-specific texts and graphics
in libraries
Edit, export and import of texts for translation
Language-specific graphics
Visual Basic and C-Script Support
IntelliSense function for fast programming of access to
runtime objects
Simple creation of control sequences in script code
Visual Basic Script debugging in simulator and
WinCC Runtime Advanced and WinCC Runtime Professional
Test and commissioning support
Simulation of HMI projects on engineering PC
Marking of incomplete or incorrect configuration directly in the
respective editor
Jump to error cause based on alarm messages in the
Compiler
Migration of existing HMI projects
Data transfer in projects from WinCC flexible
Data transfer in projects from WinCC
System prerequisites
Note:
Opening several instances of WinCC on your engineering PC at
the same time may result in more demanding hardware require-
ments.
In addition to WinCC, Windows also requires space on the hard
disk; e.g. free disk space should be available for the swap file.
The following formula has proven itself in the past: Size of swap
file = 3 x size of RAM.
For further information, refer to your Windows documentation
WinCC engineering software
Processor type (min.) Core i5; 2.4 GHz or comparable
RAM (min.) 3 GB (32-bit operating system)
8 GB (64-bit operating system)
Free hard disk space 2 GB on system drive "C:"
Operating systems 32-bit operating systems
Windows XP Home SP3
(only WinCC Basic)
Windows XP Professional SP3
• Windows 7 Home Premium SP1
(only WinCC Basic)
• Windows 7 Professional SP1
• Windows 7 Enterprise SP1
• Windows 7 Ultimate SP1
Windows Server 2003 R2 Standard
Edition SP2
(only WinCC Advanced
and Professional)
• Windows Server 2008 Standard
Edition SP2
(only WinCC Advanced
and Professional)
64-bit operating systems
• Windows 7 Home Premium SP1
(only WinCC Basic)
• Windows 7 Professional SP1
• Windows 7 Enterprise SP1
• Windows 7 Ultimate SP1
Windows Server 2008 R2 Standard
Edition SP2
(only WinCC Advanced
and Professional)
Screen resolution at least 1280 x 1024
Optical drive DVD-ROM
ST80_2013_EN_Kap04.book Seite 8 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Engineering
4/9
Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
WinCC Basic V12 SP1
Engineering software for the
configuration and simulation of
Basic Panels;
electronic documentation in English,
French, German, Italian, Spanish,
simplified Chinese, traditional Chi-
nese
• Software and documentation on
DVD, floating license, license key
on USB stick
6AV2100-0AA02-0AA5
New type of delivery:
Online software delivery
1)
,
floating license, software
and license key download,
e-mail address required for the
delivery
6AV2100-0AA02-0AH5
WinCC Comfort V12 SP1
Engineering software for the
configuration and simulation of
SIMATIC Panels;
electronic documentation in English,
French, German, Italian, Spanish,
simplified Chinese, traditional Chi-
nese
Software and documentation
on DVD, floating license,
license key on USB stick
6AV2101-0AA02-0AA5
New type of delivery:
Online software delivery
1)
,
floating license, software
and license key download,
e-mail address required for the
delivery
6AV2101-0AA02-0AH5
WinCC Advanced V12 SP1
Engineering software for the
configuration and simulation of
SIMATIC Panels;
WinCC Runtime Advanced,
electronic documentation in English,
French, German, Italian, Spanish,
simplified Chinese, traditional Chi-
nese
• Software and documentation on
DVD, floating license, license key
on USB stick
6AV2102-0AA02-0AA5
New type of delivery:
Online software delivery
1)
,
floating license, software
and license key download,
e-mail address required for the
delivery
6AV2102-0AA02-0AH5
WinCC Professional 512
PowerTags V12 SP1
Engineering software for the
configuration and simulation of
SIMATIC Panels;
WinCC Runtime Professiona
l (with max. 512 PowerTags),
WinCC Runtime Advanced
electronic documentation in English,
French, German, Italian, Spanish,
simplified Chinese, traditional Chi-
nese
• Software and documentation on
DVD, floating license,
license key on USB stick
6AV2103-0DA02-0AA5
New type of delivery:
Online software delivery
1)
,
floating license, license key
download,
e-mail address required for the
delivery
6AV2103-0DA02-0AH5
1)
Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery
WinCC Professional 4096
PowerTags V12 SP1
Engineering software for the
configuration and simulation of
SIMATIC Panels;
WinCC Runtime Professional
(with max. 4096 PowerTags),
WinCC Runtime Advanced
electronic documentation in English,
French, German, Italian, Spanish,
simplified Chinese, traditional Chi-
nese
• Software and documentation
on DVD, floating license,
license key on USB stick
6AV2103-0HA02-0AA5
• New type of delivery:
Online software delivery
1)
,
floating license, software
and license key download,
e-mail address required for the
delivery
6AV2103-0HA02-0AH5
WinCC Professional max.
PowerTags V12 SP1
Engineering software for the
configuration and simulation of
SIMATIC Panels;
WinCC Runtime Professional
(unlimited PowerTags),
WinCC Runtime Advanced
electronic documentation in English,
French, German, Italian, Spanish,
simplified Chinese, traditional Chi-
nese
• Software and documentation
on DVD, floating license,
license key on USB stick
6AV2103-0XA02-0AA5
• New type of delivery:
Online software delivery (OSD)
1)
,
floating license, software
and license key download,
e-mail address required for the
delivery
6AV2103-0XA02-0AH5
Trial licenses
on DVD, 21 day trial
• WinCC Basic V12 SP1 6AV2100-0AA02-0AA7
• WinCC Comfort/Advanced
V12 SP1 6AV2102-0AA02-0AA7
• WinCC Professional V12 SP1 6AV2103-0AA02-0AA7
ST80_2013_EN_Kap04.book Seite 9 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Engineering
4/10 Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
4
1)
Current information and availability regarding the new delivery package
can be found at:
http://www.siemens.com/tia-online-software-delivery
2)
Valid only for order numbers 6AV2100-0AA02-0AA5 and
6AV2100-0AA02-0AH5
Powerpacks
SIMATIC WinCC Engineering
System Powerpacks
(without version change)
Floating license, license key
only on USB stick
• WinCC Basic to
WinCC Comfort V12
2)
6AV2101-2AA02-0AC5
• WinCC Comfort to
WinCC Advanced V12 6AV2102-2AA02-0BD5
• WinCC Advanced to WinCC
Professional 512 PowerTags V12 6AV2103-2AD02-0AC5
• WinCC Professional Powerpack
512 PowerTags to
4096 PowerTags V12
6AV2103-2DH02-0BD5
• WinCC Professional Powerpack
4096 PowerTags to max.
PowerTags V12
6AV2103-2HX02-0BD5
Online software delivery (OSD)
1)
Floating license, license key
download only
e-mail address required for the
delivery
• WinCC Basic to
WinCC Comfort V12
2)
6AV2101-2AA02-0BJ5
• WinCC Comfort to
WinCC Advanced V12 6AV2102-2AA02-0BJ5
• WinCC Advanced to WinCC
Professional 512 PowerTags V12 6AV2103-2AD02-0BJ5
• WinCC Professional Powerpack
512 PowerTags to
4096 PowerTags V12
6AV2103-2DH02-0BJ5
• WinCC Professional Powerpack
4096 PowerTags to max.
PowerTags
6AV2103-2HX02-0BJ5
Software Update Service
For a period of 12 months and for a
fixed price, the customer is automat-
ically provided with all upgrades
and service packs for each installed
WinCC engineering system or
option.
The contract is automatically
extended by a further year unless
canceled at least 12 weeks prior to
expiration.
Software Update Service
(Standard Edition)
The delivery is implemented
according to the number of ordered
SUS products (e.g. 10 upgrade
packages with 10 DVDs, 10 USB
flash drives, etc.)
• WinCC Comfort 6AV6612-0AA00-0AL0
• WinCC Advanced 6AV6613-0AA00-0AL0
• WinCC Professional
512 PowerTags 6AV2103-0DA00-0AL0
• WinCC Professional
4096 PowerTags 6AV2103-0HA00-0AL0
• WinCC Professional
max. PowerTags 6AV2103-0XA00-0AL0
Software Update
Service (Compact Edition)
The delivery items are combined.
For several contracts, only 1 pack-
age with 1 data medium set, 1 USB
flash drive with the corresponding
number of licenses and the corre-
sponding number of CoLs will be
supplied.
Delivery items to be combined must
be ordered as one item.
• WinCC Comfort 6AV6612-0AA00-0AM0
• WinCC Advanced 6AV6613-0AA00-0AM0
• WinCC Professional
512 PowerTags 6AV2103-0DA00-0AM0
• WinCC Professional
4096 PowerTags 6AV2103-0HA00-0AM0
• WinCC Professional
max. PowerTags 6AV2103-0XA00-0AM0
Online software delivery (OSD)
1)
Software Update Service
(Download)
All deliveries to be downloaded.
E-mail address required for the
delivery
• WinCC Comfort 6AV6612-0AA00-0AY0
• WinCC Advanced 6AV6613-0AA00-0AY0
• WinCC Professional
512 PowerTags 6AV2103-0DA00-0AY0
• WinCC Professional
4096 PowerTags 6AV2103-0HA00-0AY0
• WinCC Professional
max. PowerTags 6AV2103-0XA00-0AY0
ST80_2013_EN_Kap04.book Seite 10 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
HMI Software in the TIA Portal
SIMATIC WinCC (TIA Portal) Engineering
4/11
Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
More information
Further information can be found in the Internet at:
http://www.siemens.com/tia-portal
Upgrades
WinCC V11 -> WinCC V12 SP1
Software and documentation
on DVD, upgrade license,
license key on USB stick
SIMATIC WinCC Basic V12 SP1
Upgrade V11 -> V12 SP1 6AV2100-3AA02-0AE5
SIMATIC WinCC Comfort V12 SP1
Upgrade V11 -> V12 SP1 6AV2101-3AA02-0AE5
SIMATIC WinCC Advanced
V12 SP1 Upgrade V11 -> V12 SP1 6AV2102-3AA02-0AE5
SIMATIC WinCC Professional
512 PowerTags V12 SP1
Upgrade V11 -> V12 SP1
6AV2103-3DA02-0AE5
SIMATIC WinCC Professional
4096 PowerTags V12 SP1
Upgrade V11 -> V12 SP1
6AV2103-3HA02-0AE5
SIMATIC WinCC Professional
max. PowerTags V12 SP1
Upgrade V11 -> V12 SP1
6AV2103-3XA02-0AE5
Online software delivery (OSD)
1)
Floating license, software
and license key download
e-mail address required for the
delivery
SIMATIC WinCC Basic V12 SP1
Upgrade V11 -> V12 SP1 6AV2100-3AA02-0AK5
SIMATIC WinCC Comfort V12 SP1
Upgrade V11 -> V12 SP1 6AV2101-3AA02-0AK5
SIMATIC WinCC Advanced
V12 SP1
Upgrade V11 -> V12 SP1
6AV2102-3AA02-0AK5
1)
Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery
Upgrades
WinCC flexible 2008 ->
WinCC V12 SP1
Software and documentation
on DVD, upgrade license,
license key on USB stick
• WinCC flexible 2008 Compact to
WinCC Comfort V12 SP1 6AV2101-4AB02-0AE5
• WinCC flexible 2008 Standard to
WinCC Comfort V12 SP1 6AV2101-4BB02-0AE5
• WinCC flexible 2008 Advanced to
WinCC Advanced V12 SP1 6AV2102-4AA02-0AE5
Online software delivery (OSD)
1)
Upgrade license, software and
license key download,
e-mail address required for the
delivery
• WinCC flexible 2008 Compact to
WinCC Comfort V12 SP1 6AV2101-4AB02-0AK5
• WinCC flexible 2008 Standard to
WinCC Comfort V12 SP1 6AV2101-4BB02-0AK5
• WinCC flexible 2008 Advanced to
WinCC Advanced V12 SP1 6AV2102-4AA02-0AK5
WinCC V7 RC -> WinCC V12 SP1
Software and documentation
on DVD, upgrade license,
license key on USB stick
• Upgrade
SIMATIC WinCC V7.0 RC 128 ->
WinCC Professional
512 PowerTags V12 SP1 and
WinCC RT Professional
128 PowerTags
6AV2103-4BD02-0AE5
• Upgrade
SIMATIC WinCC V7.0 RC 512 ->
WinCC Professional
512 PowerTags V12 SP1 and
WinCC RT Professional
512 PowerTags
6AV2103-4DD02-0AE5
• Upgrade
SIMATIC WinCC V7.0 RC 2048 ->
WinCC Professional
4096 PowerTags V12 SP1 and
WinCC RT Professional
2048 PowerTags
6AV2103-4FH02-0AE5
• Upgrade
SIMATIC WinCC V7.0 RC 8192 ->
WinCC Professional
max. PowerTags V12 SP1 and
WinCC RT Professional
8192 PowerTags
6AV2103-4KX02-0AE5
• Upgrade
SIMATIC WinCC V7.0 RC 65536 ->
WinCC Professional
max. PowerTags V12 SP1 and
WinCC RT Professional
65536 PowerTags
6AV2103-4MX02-0AE5
ST80_2013_EN_Kap04.book Seite 11 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
SIMATIC WinCC (TIA Portal) Runtime
4/12 Siemens ST 80 / ST PC · 2013
4
Overview
SIMATIC WinCC Runtime Advanced
visualization software
PC-based HMI solution for single-user systems directly at the
machine
Basic package for visualization, reporting and logging, user
administration, can be expanded flexibly with VB scripts
Basic package expandable by means of option packages
Can be integrated into automation solutions based on
TCP/IP networks
Expanded service concepts with remote operation,
diagnostics and administration over the intranet and Internet
in combination with email communication
SIMATIC WinCC Runtime Professional
visualization software
PC-based operator control and monitoring system for visual-
ization and operator control of processes, production flows,
machines and plants in all sectors – from the simple single-
user station through to distributed multi-user systems and
cross-location solutions with web clients. WinCC Runtime
Professional is the information hub for corporation-wide
vertical integration.
Industry-standard functions for signaling and acknowledging
events, archiving of messages and measured values, logging
of all process and configuration data, user administration, can
be expanded flexibly with VB and C scripts
Basic package expandable by means of option packages
Also included are APIs for the Runtime to utilize the open
programming interfaces
ST80_2013_EN_Kap04.book Seite 12 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Advanced
4/13
Siemens ST 80 / ST PC · 2013
Overview
PC-based HMI solution for single-user systems directly at the
machine. SIMATIC WinCC Runtime Advanced is configured with
the SIMATIC WinCC Advanced or SIMATIC WinCC Professional
configuration software.
Benefits
Functions for all visualization tasks:
- Operator functions
- Graphics and trend displays
- Alarm logging
- Report system
- Archiving (option)
- Recipe management (option)
- Audit Trail (option)
Flexible runtime functionality due to Visual Basic scripts
Innovative service concepts with remote operation,
diagnostics and administration via intranet and Internet as
well as e-mail communication to increase availability (option)
Support for simple distributed automation solutions based on
TCP/IP networks at the machine level (option)
Part of the Totally Integrated Automation Portal
- Direct access to the tag and message configuration of the
SIMATIC controller
- Excellent support of the new SIMATIC S7-1500 controller
With symbolic addressing
Access to the new memory-optimized data blocks
New alarm and diagnostics concept
- Integrated diagnostic functions for increasing productivity
Application
SIMATIC WinCC Runtime Advanced is the high-performance
visualization software for simple, machine-oriented visualization
tasks. It can be used as a single-user solution for all automation
applications in production automation, process automation and
building services automation.
SIMATIC WinCC Runtime Advanced can be used in combination
with the following HMI devices:
SIMATIC Panel PC: IPC277D, Panel PC 477B, HMI IPC477C,
IPC477D, Panel PC 577B, HMI IPC577C, Panel PC 677B,
HMI IPC677C
SIMATIC Box PC: IPC227D, Box PC 427B, IPC427C,
IPC427D, Box PC 627B, IPC627C, Box PC 827B, IPC827C
SIMATIC Rack PC: Rack PC 547B, IPC547C, IPC547D,
Rack PC 647B, IPC647C, Rack PC 847B, IPC847C
SIMATIC modular Embedded Controller: EC31
SINUMERIK PC: PCU 50.3, PCU 50.5
Standard PCs with resolutions (W x H in pixels) of:
- 4:3 format: 640 x 480, 800 x 600, 1024 x 768, 1280 x 1024,
1600 x 1200
- Widescreen format: 800 x 480, 1280 x 800, 1366 x 768,
1440 x 900, 1680 x 1050, 1920 x 1080, 1920 x 1200,
1980 x 1080
ST80_2013_EN_Kap04.book Seite 13 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Advanced
4/14 Siemens ST 80 / ST PC · 2013
4
Design
SIMATIC WinCC Runtime Advanced is available as a software
package with 128, 512, 2 048 or 4 096 PowerTags.
The term PowerTags is used to identify process variables and
area pointers that have a process link to the controller.
Variables without process link, constant limit values of variables,
and messages (up to 4 000 bit-triggered messages) are also
available for additional system performance.
The range of functions of WinCC Runtime Advanced includes
the centralized HMI components for visualizing and reporting,
and it can be expanded to suit requirements and costs by using
optional packages.
SIMATIC WinCC Runtime Advanced is configured with the
SIMATIC WinCC Advanced or SIMATIC WinCC Professional
configuration software.
Function
Visualization via Windows-compliant user interface
Made up of parameterizable screen objects and faceplates
created on a project-specific basis:
Numeric and alphanumeric input/output fields
Static text and graphic display plus vector graphics
Dynamizable graphics from HMI symbol library
Bar graph, trend curve graph with scroll and zoom function as
well as read line
Signal-specific text and graphic lists
Buttons and switches for operator-process communication
Editing fields for process values (signals)
Analog display, slider as example for further screen objects
Project-specific faceplates created from basic objects of the
system
Graphic displays for various standard graphic formats,
e.g. bitmaps, .jpg, .wmf
Alarms and messages
Discrete alarms and analog alarms as well as event-driven
Alarm-S/Alarm-D message procedure with SIMATIC S7
The new alarm and diagnostics concept of the S7-1500
controller is also supported
Freely-definable alarm classes for definition of acknowl-
edgment response and display of alarm events
Logging of alarms and process values
1)
Logging in files (e.g. CSV or TXT file) and Microsoft SQL
databases
Online evaluation of process value and alarm logs
Evaluation of process value and alarm logs using standard
Microsoft tools such as Excel
Recipes
1)
Generation of data records for machine data or production
data
Display or entry of data records via a configurable screen
object or via process screens distributed within the project
Transmission of data records from or to the controller
Import/export of data records from/to CSV files for further
processing with other tools (e.g. MS Excel)
1)
Option for SIMATIC WinCC Runtime Advanced, runtime licenses must be
purchased separately. For further information, refer to "WinCC options".
Documentation of process data, alarm events, and recipes
Time or event-driven report output
User-definable layout
Flexible expansion of integrated system function using
Visual Basic script
Language support for multilingual projects
Up to 32 online languages
Language-dependent texts and graphics
Language selection during runtime
ST80_2013_EN_Kap04.book Seite 14 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Advanced
4/15
Siemens ST 80 / ST PC · 2013
Function (continued)
User-oriented access protection according to requirements of
regulated sectors
Authentication with user ID and password
User group-specific rights
Central system-wide user administration based on
SIMATIC Logon
1)
Monitoring of changes by operators in runtime operation
1)
Recording of operator actions in an Audit Trail
1)
Onboard controller connection to many different controllers
Communication via native drivers and standard OPC channel
Simultaneous connection using several protocols: OPC Client
and SIMATIC HMI HTTP protocol are additive, i.e. they can be
used in conjunction with other controller connections
Open communication between HMI systems and with higher-
level systems
•OPC server
- Use of the visualization system as a data server
(OPC Server) for higher-level automation components,
e.g. control systems or systems in the office area
- OPC-DA-Server: tags, e.g. process values
Communication between HMI systems is established on
the basis of Ethernet networks, or via the Intranet/Internet
- Read and write access to tags. The WinCC Runtime
Advanced or SIMATIC Panels provide other SIMATIC HMI
systems or office applications with data (variables)
Sending of e-mails on demand or event-driven
- e.g. to maintenance personnel via SMTP server
(Simple Mail Transfer Protocol)
- The optional use of e-mail/SMS gateways enables access to
standard networks (external service provider required)
System diagnostics via device-specific HTML pages;
the following functions are available:
- Starting and stopping the HMI runtime for maintenance
- Remote access to recipe data records, passwords and infor-
mation specific to the HMI system
- Access to the HMI system files via a file explorer
- Download of configuration data via the Intranet/Internet
- Supplement with own HTML pages
WinCC Sm@rtServer
for the remote control via the Intranet and Internet
1)
Display and control of process screens on remote PC or Panel
A SIMATIC HMI system can be used to control or monitor
another system remotely; entry level for client/server configu-
rations for distributed operator stations or for solutions with
head end or control room
WinCC ControlDevelopment
for extending the functionality by adding own Controls
1)
Development of proprietary VB.net or C# Controls for
integration in SIMATIC WinCC Runtime Advanced
1)
Option for SIMATIC WinCC Runtime Advanced, runtime licenses must be
purchased separately. For further information, refer to "WinCC options".
System prerequisites
1)
In combination with options, more powerful systems may be required
2)
The required RAM is determined primarily by the size of the graphics used.
3)
Without taking archives into account.
In addition to WinCC, Windows also requires space on the hard
disk; e.g. free disk space should be available for the swap file.
The following formula has proven itself in the past: Size of swap
file = 3 x size of RAM.
For further information, refer to your Windows documentation.
SIMATIC WinCC
Runtime Advanced
Processor type (min.)
1)
All processors of the SIMATIC IPC,
Pentium III or processor running at
500 MHz or comparable
RAM (min.)
2)
512 MB
Free hard disk space
3)
2 GB on system drive "C:"
Operating systems 32-bit operating systems
Microsoft Windows XP Professional
SP3
• Windows Embedded Standard
2009 (for IPC / IPC2x7D,
HMI IPC4x7C only)
Microsoft Windows Server 2003 R2
StdE SP2
Microsoft Windows Server 2008
StdE SP2
Microsoft Windows 7 Professional
SP1
Microsoft Windows 7 Enterprise
SP1
Microsoft Windows 7 Ultimate SP1
Microsoft Windows Embedded
Standard 7 SP1 (for IPC / IPC2x7D,
HMI IPC4x7C only)
64-bit operating systems
Microsoft Windows 7 Professional
SP1
Microsoft Windows 7 Enterprise
SP1
Microsoft Windows 7 Ultimate SP1
Microsoft Windows Server 2003 R2
StdE SP2
Microsoft Windows Server 2008 R2
Standard Edition SP1
Optical drive DVD-ROM
ST80_2013_EN_Kap04.book Seite 15 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Advanced
4/16 Siemens ST 80 / ST PC · 2013
4
Technical specifications
The following tables of system limitations provide assistance in
estimating whether a specific project is still within the system
limitations for WinCC Runtime Advanced.
The stated maximum values are not additive.
We cannot guarantee proper functioning of configurations that
make full use of all system limits on the HMI devices.
In addition to the limitations specified, allowances must be
made for restrictions in configuration memory resources.
1)
Complex objects are: Bars, sliders, symbol library, clock, and all objects
from the Controls area.
2)
When using arrays, each array element represents a recipe element
3)
For the "segmented circular log" logging method, the number of entries for
all sequence logs is valid. The product derived from the number of circular
logs times the number of data records in this log may not be exceeded.
4)
Up to three Sm@rtClients can interconnect with the Sm@rtServer on
Panel PC 477.
5)
Event-triggered tasks are not relevant for the system limits.
SIMATIC WinCC
Runtime Advanced
Tags
Number of tags in the project 6144
Number of PowerTags 128 –4 096
Number of elements per array 1600
Number of local tags 2048
Alarms
Number of alarm classes 32
Number of discrete alarms 4000
Number of analog alarms 500
Length of an alarm in characters 80
Number of process values per alarm 8
Size of the alarm buffer 1024
Number of queued alarm events 500
Screens
Number of screens 500
Number of fields per screen 400
Number of tags per screen 400
Number of complex objects per
screen
1)
40
Recipes
Number of recipes 999
Number of elements per recipe
2)
2000
User data length in KB per data
record 256
Number of data records per recipe 5000
Logs
Number of logs 100
Number of entries per log
(including all log segments)
3)
500 000
Number of log segments 400
Cyclical trigger for tag logging 1 s
Number of tags that can be logged
per log 6144
Trends
Number of trends 800
Text lists and graphics lists
Number of graphic lists 500
Number of text lists 500
Number of entries per text or
graphic list 3500
Number of graphic objects 2000
Number of text elements 30 000
Scripts
Number of scripts 200
Communication
Number of connections 8
Number of connections based on
"SIMATIC HMI HTTP" 16
Maximum number of connected
Sm@rtClients (including a service
client)
4
4)
Help system
Number of characters in a help text 320
Languages
Number of runtime languages 32
Scheduler
Time-triggered tasks
5)
48
User administration
Number of user groups 50
Number of user rights 32
Number of users 100
SIMATIC WinCC
Runtime Advanced
ST80_2013_EN_Kap04.book Seite 16 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Advanced
4/17
Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
Basic Packages
SIMATIC WinCC Runtime
Advanced V12 SP1
Software and documentation on
DVD, including options software
1)
Single license, license key on
USB stick
• 128 PowerTags 6AV2104-0BA02-0AA0
• 512 PowerTags 6AV2104-0DA02-0AA0
2048 PowerTags 6AV2104-0FA02-0AA0
4096 PowerTags 6AV2104-0HA02-0AA0
Online software delivery (OSD)
2)
Single license, software and license
key download.
E-mail address required for the
delivery.
• 128 PowerTags 6AV2104-0BA02-0AH0
• 512 PowerTags 6AV2104-0DA02-0AH0
2048 PowerTags 6AV2104-0FA02-0AH0
4096 PowerTags 6AV2104-0HA02-0AH0
Powerpacks
SIMATIC WinCC Runtime
Advanced V12
(without version change)
Single license, license key only
on USB stick for PowerTags from
128 PowerTags to 512 PowerTags 6AV2104-2BD02-0BD0
512 PowerTags to 2048 PowerTags 6AV2104-2DF02-0BD0
2048 PowerTags to
4096 PowerTags 6AV2104-2FH02-0BD0
Online software delivery (OSD)
2)
Single license, software and license
key download.
E-mail address required for the
delivery.
128 PowerTags to 512 PowerTags 6AV2104-2BD02-0BJ0
512 PowerTags to 2048 PowerTags 6AV2104-2DF02-0BJ0
2048 PowerTags to
4096 PowerTags 6AV2104-2FH02-0BJ0
SIMATIC WinCC Runtime
Advanced V12 to
SIMATIC WinCC Runtime
Professional V12 SP1
Single license, software and docu-
mentation on DVD, license key on
USB stick for PowerTags from
• WinCC Runtime Advanced
128 PowerTags to
WinCC Runtime Professional
128 PowerTags
6AV2105-2BB02-0AC0
• WinCC Runtime Advanced
512 PowerTags to
WinCC Runtime Professional
512 PowerTags
6AV2105-2DD02-0AC0
• WinCC Runtime Advanced
2048 PowerTags to
WinCC Runtime Professional
2048 PowerTags
6AV2105-2FF02-0AC0
• WinCC Runtime Advanced
4096 PowerTags to
WinCC Runtime Professional
4096 PowerTags
6AV2105-2HH02-0AC0
Online software delivery (OSD)
2)
Single license, software and license
key download.
E-mail address required for the
delivery.
• WinCC Runtime Advanced
128 PowerTags to
WinCC Runtime Professional
128 PowerTags
6AV2105-2BB02-0AJ0
• WinCC Runtime Advanced
512 PowerTags to
WinCC Runtime Professional
512 PowerTags
6AV2105-2DD02-0AJ0
• WinCC Runtime Advanced
2048 PowerTags to
WinCC Runtime Professional
2048 PowerTags
6AV2105-2FF02-0AJ0
• WinCC Runtime Advanced
4096 PowerTags to
WinCC Runtime Professional
4096 PowerTags
6AV2105-2HH02-0AJ0
SIMATIC WinCC Runtime
Advanced to
SIMATIC WinCC Runtime
Professional ASIA V12 SP1
• SIMATIC WinCC Runtime
Professional Powerpack Runtime
Advanced 128 PowerTags
-> Runtime Professional
128 PowerTags ASIA V12 SP1
6AV2105-2BB12-0AC0
• SIMATIC WinCC Runtime
Professional Powerpack Runtime
Advanced 512 PowerTags
-> Runtime Professional
512 PowerTags ASIA V12 SP1
6AV2105-2DD12-0AC0
• SIMATIC WinCC Runtime
Professional Powerpack Runtime
Advanced 2048 PowerTags
-> Runtime Professional
2048 PowerTags ASIA V12 SP1
6AV2105-2FF12-0AC0
• SIMATIC WinCC Runtime
Professional Powerpack Runtime
Advanced 4096 PowerTags
-> Runtime Professional
4096 PowerTags ASIA V12 SP1
6AV2105-2HH12-0AC0
Upgrades
WinCC V11 to WinCC V12 SP1
SIMATIC WinCC Runtime
Advanced V11 to
SIMATIC WinCC Runtime
Advanced V12 SP1
Software and documentation on
DVD, including options software
Single license, license keys on
USB stick for
• SIMATIC WinCC Runtime
Advanced 128 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
6AV2104-3BB02-0AE0
• SIMATIC WinCC Runtime
Advanced 512 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
6AV2104-3DD02-0AE0
• SIMATIC WinCC Runtime
Advanced 2048 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
6AV2104-3FF02-0AE0
• SIMATIC WinCC Runtime
Advanced 4096 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
6AV2104-3HH02-0AE0
1) Runtime licenses for WinCC flexible Runtime Advanced options must
be purchased separately for each target system
2)
Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery
ST80_2013_EN_Kap04.book Seite 17 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Advanced
4/18 Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
4
1)
Each including 1 upgrade license to the WinCC Runtime Advanced
options
2)
Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery
More information
Further information can be found in the Internet at:
http://www.siemens.com/tia-portal
Online software delivery (OSD)
2)
Single license, software and
license key download.
E-mail address required for the
delivery.
SIMATIC WinCC Runtime
Advanced 128 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
6AV2104-3BB02-0AK0
SIMATIC WinCC Runtime
Advanced 512 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
6AV2104-3DD02-0AK0
SIMATIC WinCC Runtime
Advanced 2048 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
6AV2104-3FF02-0AK0
SIMATIC WinCC Runtime
Advanced 4096 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
6AV2104-3HH02-0AK0
Upgrades WinCC flexible 2008
to WinCC V12 SP1
SIMATIC WinCC flexible 2008
to SIMATIC WinCC Runtime
Advanced V12 SP1
Software and documentation on
DVD, including options software
single license, license keys on
USB stick for
• WinCC flexible 2008 Runtime
128 PowerTags to
WinCC Runtime Advanced
128 PowerTags
1)
6AV2104-4BB02-0AE0
• WinCC flexible 2008 Runtime
512 PowerTags to
WinCC Runtime Advanced
512 PowerTags
1)
6AV2104-4DD02-0AE0
• WinCC flexible 2008 Runtime
2048 PowerTags to
WinCC Runtime Advanced
2048 PowerTags
1)
6AV2104-4FF02-0AE0
• WinCC flexible 2008 Runtime
4096 PowerTags to
WinCC Runtime Advanced
4096 PowerTags
1)
6AV2104-4HH02-0AE0
Online software delivery (OSD)
2)
Single license, software and license
key download.
E-mail address required for the
delivery.
• WinCC flexible 2008 Runtime
128 PowerTags to
WinCC Runtime Advanced
128 PowerTags
1)
6AV2104-4BB02-0AK0
• WinCC flexible 2008 Runtime
512 PowerTags to
WinCC Runtime Advanced
512 PowerTags
1)
6AV2104-4DD02-0AK0
• WinCC flexible 2008 Runtime
2048 PowerTags to
WinCC Runtime Advanced
2048 PowerTags
1)
6AV2104-4FF02-0AK0
• WinCC flexible 2008 Runtime
4096 PowerTags to
WinCC Runtime Advanced
4096 PowerTags
1)
6AV2104-4HH02-0AK0
SIMATIC WinCC flexible Panel
Options to
SIMATIC WinCC V11 / V12
Panel Options
6AV2107-4XP00-0BF0
• WinCC flexible /Audit
for SIMATIC Panels to
SIMATIC WinCC Audit for
SIMATIC Panels
• WinCC flexible /Sm@rtAccess
for SIMATIC Panel to
SIMATIC WinCC Sm@rtServer
for SIMATIC Panels
• WinCC flexible /Sm@rtService
for SIMATIC Panels to
SIMATIC WinCC Sm@rtServer
for SIMATIC Panels
Online software delivery (OSD)
2)
Single license, license key
download only.
E-mail address required for
the delivery.
SIMATIC WinCC flexible Panel
Options to SIMATIC WinCC
V11 / V12 Panel Options
6AV2107-4XP00-0BK0
• WinCC flexible /Audit for
SIMATIC Panels to
SIMATIC WinCC Audit for
SIMATIC Panels
• WinCC flexible /Sm@rtAccess
for SIMATIC Panel to
SIMATIC WinCC Sm@rtServer
for SIMATIC Panels
• WinCC flexible /Sm@rtService
for SIMATIC Panels to
SIMATIC WinCC Sm@rtServer
for SIMATIC Panels
ST80_2013_EN_Kap04.book Seite 18 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Professional
4/19
Siemens ST 80 / ST PC · 2013
Overview
PC-based operator control and monitoring system for visual-
ization and operator control of processes, production flows,
machines and plants in all sectors – from the simple single-user
station through to distributed multi-user systems and cross-
location solutions with web clients.
SIMATIC WinCC Runtime Professional is the information hub for
corporation-wide vertical integration. SIMATIC WinCC Runtime
Professional is configured with the SIMATIC WinCC Professional
configuration software.
Benefits
Functions for all visualization tasks:
- Operator functions
- Graphics and trend displays
- Alarm logging
- Report system
- Archiving (option)
- Recipe management (option)
Universally scalable
- Expandable from single station to client-server configura-
tions
- Process visualization via the web with the
WinCC WebNavigator
Open standards for easy integration
- Efficient real-time database MS SQL Server
- Open for application modules with ActiveX controls
- Visual Basic for Applications for individual expansions
- OPC for cross-vendor communication
Part of the Totally Integrated Automation Portal
- Direct access to the tag and message configuration of the
SIMATIC controller
- Excellent support of the new SIMATIC S7-1500 controller
With symbolic addressing
Access to the new memory-optimized data blocks
New alarm and diagnostics concept
- Integrated diagnostic functions for increasing productivity
Application
SIMATIC WinCC Runtime Professional is designed for visual-
ization and operation of processes, manufacturing cycles,
machines and plants. With its powerful process interface,
especially to the SIMATIC family, and the secure data logging,
WinCC Runtime Professional enables solutions for the process
control.
The sector-neutral basic system enables universal usage in all
automation applications.
SIMATIC WinCC Runtime Professional can be used in combi-
nation with the following HMI devices:
SIMATIC PCs:
SIMATIC Panel PC: HMI IPC477C, IPC477D, Panel PC 577B,
HMI IPC577C, Panel PC 677B, HMI IPC677C
SIMATIC Box PC: IPC427C, IPC427D, Box PC 627B,
IPC627C, IPC827C
SIMATIC Rack PC: Rack PC 547B, IPC547C, IPC547D,
Rack PC 647B, IPC647C, Rack PC 847B, IPC847C
Standard PC
Design
SIMATIC WinCC Runtime Professional is available as a software
package with 128, 512, 2 048, 4 096, 8 192, 65 536 PowerTags.
PowerTags are data points that are connected to controllers or
other data sources via a WinCC Runtime Professional channel.
Up to 32 alarms can be obtained from one data point. Moreover,
internal tags without coupling are available for additional system
performance.
WinCC Runtime Professional also contains 500 archive tags.
Additional archive licenses can be obtained for greater quantity
structures.
Licenses for a multi-user configuration
The system software with the required number of PowerTags and
additionally the SIMATIC WinCC Server for Runtime Professional
option must be installed on the server. For the clients in the basic
configuration, a SIMATIC WinCC Client for Runtime Professional
license is sufficient.
Function
Visualization via Windows-compliant user interface
Made up of parameterizable screen objects and faceplates
created on a project-specific basis:
Numeric and alphanumeric input/output fields
Static text and graphic display plus vector graphics
Dynamizable graphics from HMI symbol library
Bar graph, trend curve graph with scroll and zoom function as
well as read line
Signal-specific text and graphic lists
Buttons and switches for operator-process communication
Editing fields for process values (signals)
Analog display, slider as example for further screen objects
Project-specific faceplates created from basic objects of the
system
Graphic displays for various standard graphic formats,
e.g. bitmaps, .jpg, .wmf
Alarms and messages
Discrete alarms and analog alarms, as well as event-driven
Alarm-S/Alarm-D message procedure with SIMATIC S7
The new alarm and diagnostics concept of the S7-1500
controller is also supported
Freely-definable alarm classes for definition of acknowl-
edgment response and display of alarm events
Logging of alarms and process values
1)
Signaling system for detecting and archiving events with
display and control options according to DIN 19235
Process logging for the acquisition, compression and storage
of measured values
Online evaluation of process value and alarm logs
1)
Option for SIMATIC WinCC Runtime Professional; runtime licenses must be
purchased separately. For further information, refer to "WinCC options".
ST80_2013_EN_Kap04.book Seite 19 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Professional
4/20 Siemens ST 80 / ST PC · 2013
Function (continued)
4
Recipes
1)
Generation of data records for machine data or production
data
Display or entry of data records via a configurable screen
object or via process screens distributed within the project
Transmission of data records from or to the controller
Import/export of data records for further processing with other
tools (e.g. MS Excel)
Documentation of process data, alarm events, and recipes
Time or event-driven report output
User-definable layout
Flexible expansion by means of Visual Basic Script and ANSI-C
Programming interfaces for individual access to data and
functions of WinCC Runtime Professional and for the
integration in user programs with VBA, VB Script, C-API,
C-Script (ANSI-C)
Language support for multilingual projects
Language-dependent texts and graphics
Language selection during runtime
Onboard controller connection to many different controllers
Communication via native drivers and standard OPC channel
For communication with subordinate controls
(SIMATIC protocols, PROFIBUS DP, PROFIBUS FMS, DDE
and OPC server included in the scope of delivery)
Open communication between HMI systems and
with higher-level systems
•OPC-Server
Use of the visualization system as a data server (OPC-Server)
for higher-level automation components such as control
systems or systems in the office sector
- OPC-DA-Server: tags, e.g. process values
- OPC-HDA-Server: logged process values
- OPC-A&E-Server: Alarms
- OPC-XML-DA-Server: tags, e.g. process values
- OPC-UA-DA-Server: tags, e.g. process values
•OLE DB Server
- Standardized and user-friendly access to WinCC log data
(MS SQL Server 2005).
- Access is via the OLE-DB Provider supplies all WinCC log
data available along with the accompanying process values,
as well as alarm and user texts.
- The WinCC OLE-DB provider also supports analysis
functions such as minimum, maximum, alarm hit list, etc.
WinCC WebNavigator for Runtime Professional
1)
- Option for SIMATIC WinCC Runtime Professional for
operating and monitoring plants over the Internet, company
Intranet or LAN.
- Configuration from a web server with the SIMATIC WinCC
Runtime Professional software as a single-user, client or
server version and a web client that enables operator control
and monitoring of a current WinCC Runtime Professional
project via an Internet browser with ActiveX support. The
WinCC basic system does not have to be installed on the
client computer.
WinCC DataMonitor for Runtime Professional
1)
- The WinCC DataMonitor is used for displaying and evalu-
ating current process states and historical data on office PCs
using standard tools such as Microsoft Internet Explorer or
Microsoft Excel.
The DataMonitor Client is supported by a web server with
current and historic process data and alarms. All staff
ranging from machine operators to corporate managers can
use the DataMonitor to obtain information.
1)
Option for SIMATIC WinCC Runtime Professional; runtime licenses must be
purchased separately. For further information, refer to "WinCC options".
ST80_2013_EN_Kap04.book Seite 20 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Professional
4/21
Siemens ST 80 / ST PC · 2013
Function (continued)
WinCC ControlDevelopment
for extending the functionality by adding own Controls
1)
Development of proprietary VB.net or C# Controls for
integration in WinCC Runtime Professional
1)
Option for SIMATIC WinCC Runtime Professional; runtime licenses must be
purchased separately. For further information, refer to "WinCC options".
1)
In combination with options, more powerful systems may be required
2)
The required RAM is determined primarily by the size of the graphics used.
3)
Without taking archives into account.
Note:
In addition to WinCC, Windows also requires space on the hard
disk; e.g. free disk space should be available for the swap file.
The following formula has proven itself in the past:
Size of swap file = 3 x size of RAM.
For further information, refer to your Windows documentation.
System prerequisites SIMATIC WinCC
Runtime Professional
Processor type (min.)
1)
Windows XP: 2.5 GHz P4 or
comparable, Pentium M, 1.6 GHz
or comparable
• Windows 7 (32-bit): 3.5 GHz P4
or comparable, dual core
Windows Server 2003: 3 GHz P4
or comparable
Windows Server 2008: 3 GHz P4
or comparable, dual/multi core
RAM (min.)
2)
2 GB
Free hard disk space
3)
2 GB on system drive "C:"
Operating systems 32-bit operating systems
Microsoft Windows XP Professional
SP3
Windows Embedded Standard
2009 (for IPC / IPC2x7D, HMI
IPC4x7C only)
Microsoft Windows Server 2003 R2
StdE SP2
• Microsoft Windows Server 2008
StdE SP2
Microsoft Windows 7 Professional
SP1
Microsoft Windows 7 Enterprise
SP1
Microsoft Windows 7 Ultimate SP1
Microsoft Windows Embedded
Standard 7 SP1 (for IPC / IPC2x7D,
HMI IPC4x7C only)
64-bit operating systems
Microsoft Windows 7 Professional
SP1
Microsoft Windows 7 Enterprise
SP1
Microsoft Windows 7 Ultimate SP1
Microsoft Windows Server 2003 R2
StdE SP2
Microsoft Windows Server 2008 R2
Standard Edition SP1
Graphics card 32 MB RAM, 24 bit color depth
Network Ethernet 10 Mbit/s or higher
Optical drive DVD-ROM
Integration
Integration in company-wide solutions
(IT and business integration)
WinCC Runtime Professional is strictly based on Microsoft
technology, which provides for the greatest possible compati-
bility and integration ability. ActiveX and .net Controls support
technology and sector-specific expansions.
Cross-manufacturer communication is also a simply exercise.
The reason: WinCC Runtime Professional can be used as an
OPC client and server, and in addition to access to current
process values, it also supports standards such as OPC HDA
(Historical Data Access), OPC Alarm & Events, OPC UA Data
Access and OPC XML Data Access. Just as important: Visual
Basic Scripting (VBS) as an easy-to-learn, open Runtime
language. If desired, professional application developers can
also use ANSI-C.
WinCC Runtime Professional integrates a powerful and scalable
Historian function based on the Microsoft SQL Server in the
basic system.
Thus the user is given all possibilities: from high-performance
archiving of current process data, to long-term archiving with
high data compression, through to a central information
turntable in form of a company-wide Process Historian.
Open interfaces form the basis for an effective IT and business
integration.
ST80_2013_EN_Kap04.book Seite 21 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Professional
4/22 Siemens ST 80 / ST PC · 2013
4
Technical specifications
The following tables of system limits provide assistance in
estimating whether a specific project is still within the system
limitations for WinCC Runtime Professional. The stated maximum
values are not additive.
We cannot guarantee proper functioning of configurations that
make full use of all system limits on the HMI devices. In addition
to the limitations specified, allowances must be made for restric-
tions in configuration memory resources.
1)
Limited by system resources.
2)
On single-user station or server or on client per server if "LongTimeArchive-
Consistency" is set to "No". On single-user station, server, or client if
"LongTimeArchiveConsistency" is set to "Yes".
3)
On single-user station or server or on client per server.
4)
The number and complexity of the objects affect the performance.
5)
Limited by system resources.
6)
The sum of the number of recipe elements and number of data records
must not exceed a value of 320,000.
7)
Dependent on the Logging Powerpack used for the log tags.
500 log tags are contained in the basis version.
8)
If the server is also used as an operating unit, the number of clients for this
server is reduced to four.
9)
Mixed configuration: 32 Clients + 3 Web Clients
10)
Mixed configuration: 50 Web Clients + 1 WinCC Client
SIMATIC WinCC
Runtime Professional
Alarms
Configurable alarms
per server/single user 20 000
PowerTags per alarm line 10
User text blocks per alarm line 10
Alarm classes
(incl. system alarm classes) 18
Alarm types 16
Alarm priorities 17 (0...16)
Alarms in Runtime
Alarms per alarm log Unlimited
1)
Alarms per short-term log list 1 000
Alarms per long-term log list 1 000
2)
Alarms per alarm display 5 000
3)
Screens
Objects per screen
4)
3 000
5)
Levels per screen 32
Screens per project 1 000
5)
Instances of fixed faceplates
in a process screen 31 instances of the same picture
type
Screen size in pixels 10 000 x 10 000
Nesting levels of screen objects 20
Recipes
Number of recipes 1 000
5)
Number of recipe elements 500
6)
Number of recipe data records 3 000
6)
Number of views Unlimited
5)
Logs
Trend views per screen 25
Trends per trend view 80
Tables per screen 25
Columns per table 12
Values per table 30 000
Logs per single-user station/server 100
Log tags per single-user station/
server
7)
8 000
Trends
Trend views per image 25
Trends per trend view 80
User administration
Number of user groups 128
Number of user rights 999
Number of users 128
Configurations – Quantity structure
in a multi-user system
WinCC clients in a system 32
8) 9)
Web clients in a system 50
10)
SIMATIC WinCC
Runtime Professional
ST80_2013_EN_Kap04.book Seite 22 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Professional
4/23
Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
Basic software
SIMATIC WinCC
Runtime Professional V12 SP1
For PC systems;
incl. software options
1)
,
language/script versions:
DE, EN, FR, IT, ES
Single License, on DVD
incl. licensing, on USB stick, for:
• 128 PowerTags 6AV2105-0BA02-0AA0
• 512 PowerTags 6AV2105-0DA02-0AA0
2048 PowerTags 6AV2105-0FA02-0AA0
4096 PowerTags 6AV2105-0HA02-0AA0
8192 PowerTags 6AV2105-0KA02-0AA0
65535 PowerTags 6AV2105-0MA02-0AA0
Incl. 500 archive tags each
Online software delivery (OSD)
3)
Single license, software and
license key download.
E-mail address required
for the delivery.
• 128 PowerTags 6AV2105-0BA02-0AH0
• 512 PowerTags 6AV2105-0DA02-0AH0
2048 PowerTags 6AV2105-0FA02-0AH0
4096 PowerTags 6AV2105-0HA02-0AH0
8192 PowerTags 6AV2105-0KA02-0AH0
65535 PowerTags 6AV2105-0MA02-0AH0
Incl. 500 archive tags each
SIMATIC WinCC
Runtime Professional ASIA
V12 SP1
For PC systems;
incl. software options
1)
,
language/script versions:
EN, CHs, CHt, KOR, JPN
Single License, on DVD
incl. licensing, for:
• 128 PowerTags 6AV2105-0BA12-0AA0
• 512 PowerTags 6AV2105-0DA12-0AA0
2048 PowerTags 6AV2105-0FA12-0AA0
4096 PowerTags 6AV2105-0HA12-0AA0
8192 PowerTags 6AV2105-0KA12-0AA0
65535 PowerTags 6AV2105-0MA12-0AA0
Incl. 500 archive tags each
SIMATIC WinCC Client for
Runtime Professional
• WinCC Client for
Runtime Professional 6AV2107-0DB02-0AA0
• WinCC Client for
Runtime Professional
(form of delivery OSD
3)
)
6AV2107-0DB02-0AH0
• WinCC Client for
Runtime Professional ASIA 6AV2107-0DB12-0AA0
1)
Runtime licenses for WinCC Runtime Professional options must be
purchased separately for each target system.
2)
Each including 1 upgrade license to the WinCC Runtime Professional
options.
3)
Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery
Powerpacks
SIMATIC WinCC
Runtime Professional V12 and
SIMATIC WinCC
Runtime Professional ASIA V12
Single license, license key only on
USB sticks for PowerTags from
• 128 to 512 PowerTags 6AV2105-2BD02-0BD0
• 512 to 2048 PowerTags 6AV2105-2DF02-0BD0
• 2048 to 4096 PowerTags 6AV2105-2FH02-0BD0
• 4096 to 8192 PowerTags 6AV2105-2HK02-0BD0
• 8192 to 65536 PowerTags 6AV2105-2KM02-0BD0
Online software delivery (OSD)
3)
Single license, license key
download only.
E-mail address required
for the delivery.
• 128 to 512 PowerTags 6AV2105-2BD02-0BJ0
• 512 to 2048 PowerTags 6AV2105-2DF02-0BJ0
• 2048 to 4096 PowerTags 6AV2105-2FH02-0BJ0
• 4096 to 8192 PowerTags 6AV2105-2HK02-0BJ0
• 8192 to 65536 PowerTags 6AV2105-2KM02-0BJ0
Upgrades WinCC V11
to WinCC V12 SP1
SIMATIC WinCC
Runtime Professional V11 to
SIMATIC WinCC
Runtime Professional V12 SP1
and SIMATIC WinCC
Runtime Professional ASIA V11
to SIMATIC WinCC
Runtime Professional ASIA
V12 SP1
Single license, on DVD
incl. licensing on USB stick
• SIMATIC WinCC Runtime
Professional 128 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
6AV2105-3BB02-0AE0
• SIMATIC WinCC Runtime
Professional 512 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
6AV2105-3DD02-0AE0
• SIMATIC WinCC Runtime
Professional 2048 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
6AV2105-3FF02-0AE0
• SIMATIC WinCC Runtime
Professional 4096 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
6AV2105-3HH02-0AE0
• SIMATIC WinCC Runtime
Professional 8192 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
6AV2105-3KK02-0AE0
• SIMATIC WinCC Runtime
Professional 65536 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
6AV2105-3MM02-0AE0
ST80_2013_EN_Kap04.book Seite 23 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Professional
4/24 Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
4
1)
Each including 1 upgrade license to the WinCC Runtime Professional
options.
2)
Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery
More information
Further information can be found in the Internet at:
http://www.siemens.com/tia-portal
Upgrades WinCC V11
to WinCC V12 SP1
(continued)
Online software delivery (OSD)
2)
Single license, software and
license key download.
E-mail address required
for the delivery.
SIMATIC WinCC Runtime
Professional 128 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
6AV2105-3BB02-0AK0
SIMATIC WinCC Runtime
Professional 512 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
6AV2105-3DD02-0AK0
SIMATIC WinCC Runtime
Professional 2048 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
6AV2105-3FF02-0AK0
SIMATIC WinCC Runtime
Professional 4096 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
6AV2105-3HH02-0AK0
SIMATIC WinCC Runtime
Professional 8192 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
6AV2105-3KK02-0AK0
SIMATIC WinCC Runtime
Professional 65536 PowerTags
V12 SP1
Upgrade V11 -> V12 SP1
6AV2105-3MM02-0AK0
Upgrades WinCC V7
to WinCC V12 SP1
SIMATIC WinCC V7.0
to SIMATIC WinCC
Runtime Professional V12 SP1
and SIMATIC WinCC V7.0 ASIA
to SIMATIC WinCC
Runtime Professional ASIA
V12 SP1
Single license, on DVD
incl. licensing on USB stick
6AV2105-4BB02-0AE0
• WinCC V7.0 Runtime
128 PowerTags to
WinCC Runtime Professional
128 PowerTags V12 SP1
1)
6AV2105-4DD02-0AE0
• WinCC V7.0 Runtime
512 PowerTags to
WinCC Runtime Professional
512 PowerTags V12 SP1
1)
6AV2105-4FF02-0AE0
Upgrades WinCC V7
to WinCC V12 SP1
(continued)
SIMATIC WinCC V7.0
to SIMATIC WinCC
Runtime Professional V12 SP1
and SIMATIC WinCC V7.0 ASIA
to SIMATIC WinCC
Runtime Professional ASIA
V12 SP1
• WinCC V7.0 Runtime
2048 PowerTags to
WinCC Runtime Professional
2048 PowerTags V12 SP1
1)
6AV2105-4KK02-0AE0
• WinCC V7.0 Runtime
8192 PowerTags to
WinCC Runtime Professional
8192 PowerTags V12 SP1
1)
6AV2105-4MM02-0AE0
• WinCC V7.0 Runtime
65536 PowerTags to
WinCC Runtime Professional
65536 PowerTags V12 SP1
1)
6AV2107-4DB02-0AE0
• WinCC V7.0 RC/RT128 / RC/RT
Client to WinCC Client for
Runtime Professional V12 SP1
6AV2105-4BB02-0AE0
Online software delivery (OSD)
2)
Single license, software and
license key download.
E-mail address required
for the delivery.
• WinCC V7.0 Runtime
128 PowerTags to
WinCC Runtime Professional
128 PowerTags V12 SP1
1)
6AV2105-4BB02-0AK0
• WinCC V7.0 Runtime
512 PowerTags to
WinCC Runtime Professional
512 PowerTags V12 SP1
1)
6AV2105-4DD02-0AK0
• WinCC V7.0 Runtime
2048 PowerTags to
WinCC Runtime Professional
2048 PowerTags V12 SP1
1)
6AV2105-4FF02-0AK0
• WinCC V7.0 Runtime
8192 PowerTags to
WinCC Runtime Professional
8192 PowerTags V12 SP1
1)
6AV2105-4KK02-0AK0
• WinCC V7.0 Runtime
65536 PowerTags to
WinCC Runtime Professional
65536 PowerTags V12 SP1
1)
6AV2105-4MM02-0AK0
• WinCC V7.0 RC/RT128 / RC/RT
Client to WinCC Client for
Runtime Professional V12 SP1
6AV2107-4DB02-0AK0
ST80_2013_EN_Kap04.book Seite 24 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Communication
4/25
Siemens ST 80 / ST PC · 2013
Overview
Communication – SIMATIC WinCC Runtime Advanced
WinCC Advanced is an open visualization system and offers the
option of connecting the most diverse control systems.
Number of connectable controllers
WinCC Advanced permits the parallel coupling of up to
8 controllers.
Connection to third-party controllers
The following "Coupling overview" table lists third-party protocols
and controllers which are directly supported by WinCC
Advanced. Generally it is also possible to connect third-party
controllers via OPC (OLE for Process Control).
Current notes and information about OPC servers from many
different suppliers can be found at:
http://www.opcfoundation.org/
WinCC Advanced supports the standards:
OPC Data Access 2.05a
OPC UA Data Access 1.01
OPC XML Data Access 1.00 (client via DCOM/XML gateway)
1)
HTTP and OPC communication can be used in combination with the other
couplings; regarding SIMATIC Panels
that support HTTP or OPC
communication, see the overview under "System interfaces
(WinCC V11)".
2)
"SINUMERIK Operate WinCC RT Advanced" license required;
for further information, see NC 60 Catalog.
3)
For detailed information regarding supported controllers,
see "System interfaces (WinCC V11)"
4)
Application note:
The parallel use of the OPC client channel allows, for example, the
connection to an SNMP OPC Server for visualization of the data
present there. The SNMP OPC Server enables monitoring of any
network components (e.g. switch) that support the SNMP protocol.
Further information can be foundunder SIMATIC NET communications
systems/SNMP OPC Server.
Protocol Description PC interface
SIMATIC HMI
Ethernet TCP/IP
(HTTP communication) HTTP communication for data
exchange between SIMATIC
HMI (client + server)
1)
CP 1612 A2
SIMATIC S7
Ethernet TCP/IP
(S7 communication) Channel for communication via
Ethernet TCP/IP with max. 8 x
SIMATIC S7 controllers
S7-1200, S7-1500
S7-300, S7-400,
S7-200 with CP 243-1
CP 1612 A2
CP 1613 A2
CP 1623
MPI, PROFIBUS
(S7 communication) Channel for communication via
MPI, PROFIBUS with max. 8 x
SIMATIC S7 controllers
S7-1200 with CM 1243-5
(DP master), S7-1500
S7-300, S7-400
S7-200 (only passive S7-200)
CP 5611 A2
CP 5621
CP 5512
CP 5711
CP 5613 A2
CP 5623
PPI
(PPI protocol) Channel for communication via
PPI with
1 x SIMATIC S7-200
(network operation,
e.g. parallel PG possible)
CP 5611 A2
CP 5621
CP 5512
CP 5711
CP 5613 A2
CP 5623
Software interface
(S7 communication) Channel for communication via
software interface with WinAC
SINUMERIK
2)
Ethernet TCP/IP
(S7 communication) Channel for communication
via Ethernet TCP/IP
with SINUMERIK 840D sl
CP 1612 A2
CP 1613 A2
CP 1623
MPI
(S7 communication) Channel for communication
via MPI with
SINUMERIK 840D sl
CP 5611 A2
CP 5621
CP 5512
CP 5711
CP 5613 A2
CP 5623
Third-party controllers (from WinCC V11.0)
3)
Allen Bradley
Ethernet IP Channel for communication
with max. 4 x Allen Bradley
controllers via Ethernet TCP/IP
with Allen Bradley Ethernet IP
protocol
The controllers ControlLogix /
CompactLogix, SLC500 /
MicroLogix and PLC5 are
supported
CP 1612 A2
Allen Bradley DF1 Channel for communication
with Allen Bradley controllers
via DF1 protocol
The controllers SLC500 /
MicroLogix and PLC5 are
supported
3)
COM1/COM2
Mitsubishi MC TCP/IP Channel for communication with
max. 4 x Mitsubishi controllers
via Ethernet TCP/IP with Mit-
subishi MC TCP/IP protocol
The FX3, Q, and iQ/QnUD
controller series are supported
CP 1612 A2
Mitsubishi FX Channel for communication
with Mitsubishi controllers
via FX protocol
The FX1N, FX2N controllers are
supported
COM1/COM2
Modbus TCP/IP Channel for communication
with max. 4 x Modicon control-
lers via Ethernet TCP/IP using
the Modbus TCP/IP protocol
The Quantum, Momentum,
Premium, TSX Micro, Compact
and M340 controllers are
supported
CP 1612 A2
Modbus RTU Channel for communication
with Modicon controllers via
the Modbus RTU protocol
The Quantum, Momentum,
and Compact controllers are
supported
COM1/COM2
Omron Link / Multi Link Channel for communication
with Omron controllers via the
Link/Multi protocol
The CP1x, CJ1x, CJ2H, CS1x,
and CP2MC controllers are
supported
COM1/COM2
Cross-manufacturer
OPC client
1) 4)
for
OPC DA, OPC UA DA,
XML DA
Channel for OPC communica-
tion, WinCC can acquire data
from OPC server applications
CP 1612 A2
OPC server for OPC DA Server applications for
OPC communication;
WinCC provides process data
to OPC clients
CP 1612 A2
Protocol Description PC interface
ST80_2013_EN_Kap04.book Seite 25 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Communication
4/26 Siemens ST 80 / ST PC · 2013
Overview (continued)
4
Communication – SIMATIC WinCC Runtime Professional
WinCC Professional is an open process visualization system and
offers the option of connecting the most diverse control systems.
Released communication software
Only communication software with the listed (or higher) product
versions should be used. Corresponding SIMATIC NET
upgrades are available for the upgrading of older versions.
Number of connectable controllers
With CP 1613, a maximum of 64 S7 controllers can be connected
via Industrial Ethernet; with CP 5611 a maximum of 8 and with
CP 5613 a maximum of 44 S7 controllers can be connected via
PROFIBUS. With approx. 10 or more controllers, the use of
Industrial Ethernet is recommended.
Client-server communication
Communication between the clients and the server is imple-
mented using the TCP/IP protocol. The construction of a
separate PC-LAN is recommended. For small projects with
correspondingly small message frame advent, a SIMATIC NET
Industrial Ethernet can be used for both process communication
(WinCC/server PLC) and for PC-PC communication
(WinCC/client WinCC/server)
Connection to third-party controllers
The following "Coupling overview" table lists third-party protocols
and controllers which are directly supported by WinCC Profes-
sional. Generally it is also possible to connect third-party
controllers via OPC (OLE for Process Control).
Current notes and information about OPC servers from many
different suppliers can be found at:
http://www.opcfoundation.org/
WinCC Professional supports the standards:
OPC Data Access 2.05a
OPC Data Access 3.00
OPC UA Data Access 1.01
OPC XML Data Access 1.00
OPC HDA 1.20
OPC A&E 1.10
1)
Application note:
The parallel use of the OPC client channel allows, for example, the
connection to an SNMP OPC Server for visualization of the data present
there.
The SNMP OPC Server enables monitoring of any network components
(e.g. switch) that support the SNMP protocol.
Further information can be foundunder SIMATIC NET communications
systems/SNMP OPC Server.
Protocol Description PC interface
SIMATIC S7
SIMATIC S7 Protocol Suite with channel
units for communication with
SIMATIC S7 via
• Ethernet TCP/IP
(S7 communication) to
S7-1200, S7-1500, S7-300,
S7-400
• MPI, PROFIBUS
(S7 communication) to
S7-1200 with CM 1243-5
(DP master), S7-1500, S7-300,
S7-400
• Software interface
(S7 communication)
to Win AC
CP 1612 A2
CP 1613 A2
CP 5611 A2
CP 5621
CP 5512
CP 5711
CP 5613 A2
CP 5623
Third-party controllers (from WinCC V11.0)
Allen Bradley
Ethernet IP Channel for communication with
Allen Bradley controllers via
Ethernet TCP/IP with Ethernet IP
protocol
The controllers ControlLogix /
CompactLogix,
SLC500 / MicroLogix,
and PLC5 are supported
CP 1612 A2
Mitsubishi MC TCP/IP Channel for communication
with Mitsubishi controllers via
Ethernet TCP/IP with
Mitsubishi MC TCP/IP protocol
The FX3, Q, and iQ/QnUD
controller series are supported
CP 1612 A2
Modbus TCP/IP Channel for communication with
Modicon controllers via Ethernet
TCP/IP using the Modbus TCP/
IP protocol
The Quantum, Momentum, Pre-
mium, TSX Micro, Compact and
M340 controllers are supported
CP 1612 A2
Cross-manufacturer
OPC client
1)
for
OPC DA, OPC XML DA Channel for OPC communica-
tion, WinCC can acquire data
from OPC server applications
CP 1612 A2
OPC server for
OPC DA, OPC UA DA,
OPC XML DA,
OPC A&E, OPC HDA
Server applications for
OPC communication;
WinCC provides process data
to OPC clients
CP 1612 A2
ST80_2013_EN_Kap04.book Seite 26 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Communication
4/27
Siemens ST 80 / ST PC · 2013
Overview (continued)
WinCC Runtime Advanced single-user system
WinCC Runtime Professional multi-user system with operable Server
Industrial Ethernet
WinCC
Runtime
Advanced
PROFIBUS
SIMATIC S7-300 SIMATIC S7-1200
*B67B;;B
SIMATIC S7-400
WinCC RT
Professional
Client
WinCC RT
Professional
Client
WinCC RT
Professional
Client
WinCC RT
Professional
Client
*B67B;;B
Industrial Ethernet
PROFIBUS
SIMATIC S7-400 SIMATIC S7-400
WinCC RT
Professional
Server
ST80_2013_EN_Kap04.book Seite 27 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Communication
4/28 Siemens ST 80 / ST PC · 2013
Overview (continued)
4
OPC coupling
WinCC RT
Professional
Industrial Ethernet
WinCC RT
Advanced
OPC Client
OPC Server
PROFIBUS
SIMATIC S7-300 SIMATIC S7-1200
*B67B;;B
ST80_2013_EN_Kap04.book Seite 28 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Communication
4/29
Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
Communication
via Industrial Ethernet TCP/IP
CP 1612 A2 6GK1161-2AA01
PCI card (32-bit) for connection of
a programming device or PC to
Industrial Ethernet
(10/100/1000 Mbit/s) with RJ45
connection via SOFTNET S7 and
SOFTNET PG.
Software requirement:
WinCC Runtime Advanced:
No further installation is required
(SOFTNET-S7)
WinCC Runtime Professional:
SOFTNET-S7 Lean (maximum of
8 connections) or SOFTNET-S7
(maximum of 64 connections) must
be installed (SOFTNET-S7 Lean is
included in the scope of delivery of
WinCC Runtime Professional)
SOFTNET-S7 Version 8.0 SP1 /
Edition 2008 SP2 (V7.1)
Software for S7 and S5-compatible
communication, incl. OPC server,
PG/OP communication and NCM
PC; up to 64 connections, single
license for 1 installation, runtime
software, software and electronic
manual on CD-ROM, license key on
USB flash drive, Class A
Version 8.0 SP1
For (32-bit) Windows 7 Ultimate,
Professional;
for CP 1612; CP 1612 A2
German/English
(included in the scope of delivery:
Edition 2008 SP2 (V7.1) )
Edition 2008 SP2 (V7.1)
For (32-bit) Windows XP Profes-
sional, Windows 2003 Server,
VISTA Ultimate/Business;
for CP 1612; CP 1612 A2
German/English
Single license for 1 installation 6GK1704-1CW80-3AA0
Upgrade package for
SIMATIC NET from Edition 2006 6GK1704-1CW00-3AE0
Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2
and Edition 2005
6GK1704-1CW00-3AE1
SOFTNET-S7 Lean Version 8.0
SP1 / Edition 2008 SP2 (V7.1)
(included in the scope of delivery of
WinCC V11)
Software for S7-compatible and
S5-compatible communication
incl. OPC server, PG/OP
communication and NCM PC;
up to 8 connections; single license
for one installation of runtime
software,
software and electronic manual
on CD-ROM;
license key on USB stick; Class A
Version 8.0 SP1
For (32-bit) Windows 7 Ultimate,
Professional; for CP 1612;
CP 1612 A2 German/English
(included in scope of supply:
Edition 2008 SP2 (V7.1) )
Edition 2008 SP2 (V7.1)
For (32-bit) Windows XP
Professional, Windows 2003 Server,
VISTA Ultimate/Business;
for CP 1612; CP 1612 A2
German/English
• Single license for 1 installation 6GK1704-1LW80-3AA0
• Upgrade package for
SIMATIC NET from Edition 2006 6GK1704-1LW00-3AE0
• Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2
and Edition 2005
6GK1704-1LW00-3AE1
CP 1613-A2 6GK1161-3AA01
PCI card (32 bit) for connecting a
PG/PC to Industrial Ethernet
(communications software must
be ordered separately)
S7-1613 Version 8.0 SP1 /
Edition 2008 SP2 (V7.1)
Software for S7 and S5-compatible
communication, incl. PG/OP com-
munication, OPC server and NCM
PC; up to 120 connections, single
license for 1 installation, runtime
software, software and electronic
manual on CD-ROM, license key
on USB flash drive, Class A
Version 8.0 SP1
For (32-bit) Windows 7 Ultimate,
Professional;
for CP 1613; CP 1613 A2,
CP 1623 German/English
(included in the scope of delivery:
Edition 2008 SP2 (V7.1) )
Edition 2008 SP2 (V7.1)
For (32-bit) Windows XP
Professional, Windows 2003 Server,
VISTA Ultimate/Business;
for CP 1613; CP 1613 A2,
CP 1623 German/English
• Single license for 1 installation 6GK1716-1CB80-3AA0
• Upgrade package for
SIMATIC NET from Edition 2006 6GK1716-1CB00-3AE0
• Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2
and Edition 2005
6GK1716-1CB00-3AE1
CP 1623 6GK1162-3AA00
PCI Express X1 card (32-bit) for
connection of PG/PC to Industrial
Ethernet (communications software
to be ordered separately)
ST80_2013_EN_Kap04.book Seite 29 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) Runtime
WinCC Runtime Communication
4/30 Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
4
Communication via PROFIBUS
PC adapter USB 6ES7972-0CB20-0XA0
Can be used under Windows XP
CP 5611 A2 6GK1561-1AA01
PCI Card (32-bit) for connecting a
PG/PC to PROFIBUS
(Communication software included
in the WinCC basic package)
CP 5621 6GK1562-1AA00
PCI Express X1 card (32-bit) for
connection of PG/PC to PROFIBUS
(communications software included
in WinCC basic package)
CP 5621 MPI 6GK1562-1AM00
Comprising CP 5621 (32-bit) and
MPI cable, 5 m
CP 5512 6GK1551-2AA00
PCMCIA card (CARDBUS 32-bit)
for the connection of a PG/notebook
to PROFIBUS or MPI
(communications software included
in WinCC basic package)
CP 5711 6GK1571-1AM00
USB adapter for connecting a
PG/PC to PROFIBUS or MPI
(communications software included
in the WinCC basic package)
CP 5613 A2 6GK1561-3AA01
PCI card (32-bit) for connecting
a PC to PROFIBUS
(communications software must
be ordered separately).
CP 5623 6GK1562-3AA00
PCI Express X1 card (32-bit) for
connection of PG/PC to Industrial
Ethernet (communications software
to be ordered separately)
S7-5613 Version 8.0 SP1 /
Edition 2008 SP2 (V7.1)
Software for S7 Communication incl.
PG/OP protocol, FDL, OPC server;
runtime software, software and
electronic manual on CD-ROM,
license key on USB flash drive,
Class A
Version 8.0 SP1
For (32-bit) Windows 7 Ultimate,
Professional; for CP 5613 A2,
CP 5623 German/English
For (32-bit) Windows XP
Professional, Windows 2003 Server,
VISTA Ultimate/Business;
for CP 5613 A2, CP 5623
German/English
• Single license for 1 installation 6GK1713-5CB80-3AA0
• Upgrade package for
SIMATIC NET from Edition 2006 6GK1713-5CB00-3AE0
• Upgrade package
for SIMATIC NET V6.0, V6.1, V6.2
and Edition 2005
6GK1713-5CB00-3AE1
ST80_2013_EN_Kap04.book Seite 30 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
SIMATIC WinCC (TIA Portal) options
4/31
Siemens ST 80 / ST PC · 2013
Overview
Options for SIMATIC Panels,
SIMATIC WinCC Runtime Advanced and
SIMATIC WinCC Runtime Professional
SIMATIC WinCC Recipes
for SIMATIC WinCC Runtime Advanced and
SIMATIC WinCC Runtime Professional
Generation and management of data records for machine or
production data
Display or entry of data records via a configurable screen
object or via process screens distributed within the project
Transmission of data records from or to the controller
Import/export of data records for further processing with other
tools (e.g. MS Excel)
SIMATIC WinCC Logging
for SIMATIC WinCC Runtime Advanced
and SIMATIC WinCC Runtime Professional
Logging of alarms and process values
Online evaluation of process value logs and alarm logs
Evaluation of process value and alarm logs using standard
MS tools such as Excel
SIMATIC WinCC Audit
for SIMATIC Panels and SIMATIC WinCC Runtime Advanced
Recording of operator actions in an Audit Trail
Electronic signature for important operator actions relevant to
production
Audit supports users in meeting special quality requirements,
e.g.
- Production plant requiring validation according to 21 CFR
Part 11 (Food Drug Administration law)
- In respect of traceability according to EU 175/2002
(EU directive)
SIMATIC Logon
for SIMATIC Panels and SIMATIC WinCC Runtime Advanced
and SIMATIC WinCC Runtime Professional
Creates user administration on a central computer to which
one or more WinCC stations can be connected over Ethernet.
With each logging-on/off of a user on one of the connected
stations, SIMATIC Logon checks whether a user password has
been created and that the required privileges exist.
SIMATIC Logon supports the user in combination with the
Audit option in meeting requirements in accordance with
FDA 21 CFR Part 11 and EU178.
SIMATIC WinCC Sm@rtServer
for SIMATIC Panels and SIMATIC WinCC Runtime Advanced
Flexible solution for remote access to HMI systems
Remote maintenance of machines and plants via the Internet/
Intranet
Reduced downtimes for machines and plants due to direct
remote access
Flexible solution for remote access to machines and plants
SIMATIC WinCC Server and SIMATIC WinCC Client
for SIMATIC WinCC Runtime Professional
For setting up a high-performance client-server system
A number of coordinated HMI stations can be operated in a
single group with networked automation systems
Client/server solution:
- One server can supply up to 32 connected clients with
process and archive data, alarms, screens and reports
- Depending on the size of the plant, up to 12 servers and
32 clients can be employed.
SIMATIC WinCC WebNavigator
for SIMATIC WinCC Runtime Professional
Operator control and monitoring of plants via the Internet or
the in-house intranet or LAN
Web Client permits the operator control and monitoring of a
current WinCC Runtime Professional project via an Internet
browser with ActiveX support.
SIMATIC WinCC DataMonitor
for SIMATIC WinCC Runtime Professional
Display and analysis of current process states and historical
data on office PCs with standard tools.
Information can be compiled online individually during
runtime via the Internet/Intranet.
SIMATIC WinCC ControlDevelopment
for SIMATIC WinCC Runtime Advanced and
SIMATIC WinCC Runtime Professional
Expansion of the basic functionality with proprietary controls.
Development of proprietary VB.net or C# Controls for
integration in WinCC Runtime Advanced and WinCC Runtime
Professional
ST80_2013_EN_Kap04.book Seite 31 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC Recipes
4/32 Siemens ST 80 / ST PC · 2013
4
Overview
Option for SIMATIC WinCC Runtime Advanced and
WinCC Runtime Professional for managing data records in
recipes that contain related machine or production data
The data in a data set can be transferred, for example, from
the control unit to the PLC to switch production to a different
product variant
• Licensing:
- SIMATIC Panels / Multi Panels / Comfort Panels:
No license is required.
- WinCC Runtime Advanced:
One license is required per operator station
- WinCC Runtime Professional:
A license is only required on the server
(or single-user system).
Benefits
Generation and management of machine parameters and
production data on the basis of data records, and exchange
with the automation device, e.g. with the machine.
Clear tabular representation of the data elements with the aid
of a configurable screen object, or depiction in technological
relationships across several process screens.
Simple operator guidance through standard functions.
Export/import of data records for further processing with other
tools (e.g. MS Excel)
Function
Input of data records (e.g. operating parameters of a
machine, production data for a plastics machine) on the
HMI device as well as their storage and transfer to the control
Display or entry of data records via a configurable screen
object or via several process screens distributed within the
project
The data record elements are coupled with the process via a
direct tag connection
Transmission of data records from or to the controller
Powerful interfaces enable a synchronized data exchange
with the controller
Storage of data records on local data carriers or on remote
data servers via networks
Logging of data records, e.g. as batch report/shift report
User-friendly and flexible management of data records by
powerful standard functions
The recipes and the associated data records are created using
a separate, user-friendly WinCC Engineering editor and data is
pre-assigned to them. A configurable table object is used for
displaying the data at runtime. Furthermore, the individual data
record elements can also be displayed directly based on
standard input/output fields across several process screens.
In this way, the data in technological views can be presented
clearly to the operator.
Import and export functions support the importing and exporting
of data via external applications (e.g. MS Excel).
ST80_2013_EN_Kap04.book Seite 32 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC Recipes
4/33
Siemens ST 80 / ST PC · 2013
Technical specifications
1)
When using arrays, each array element represents a recipe element
2)
Limited by system resources.
3)
The sum of the number of recipe elements and number of data records
must not exceed a value of 320,000.
Ordering data
Order No.
1)
One license is required for each operator console. A license is not required
for the engineering system for configuring the runtime option.
2)
Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery
WinCC Recipes
for Runtime Advanced
The values specified are maximum
values
Number of recipes 999
Number of elements per recipe
1)
2000
User data length in KB per data
record 256
Number of data records per recipe 5000
WinCC Recipes
for Runtime Professional
The values specified are maximum
values
Number of recipes Unlimited
2)
Number of elements per recipe
2)
500
3)
User data length in KB per data
record 3 000
3)
Number of data records per recipe 5000
2)
SIMATIC WinCC Recipes for
Runtime Advanced
1)
6AV2107-0JA00-0BB0
Single license, license key
only on USB stick
SIMATIC WinCC Recipes +
Logging for Runtime Advanced
1)
6AV2107-0HA00-0BB0
Single license, license key
only on USB stick
SIMATIC WinCC Recipes for
Runtime Professional
1)
6AV2107-0JB00-0BB0
Single license, license key
only on USB stick
Online software delivery (OSD)
2)
WinCC Recipes for
Runtime Advanced
1)
6AV2107-0JA00-0BH0
Single license, license key
download only; E-mail address
required for the delivery
WinCC Recipes for
Runtime Professional
1)
6AV2107-0JB00-0BH0
Single license, license key
download only; E-mail address
required for the delivery
ST80_2013_EN_Kap04.book Seite 33 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC Logging
4/34 Siemens ST 80 / ST PC · 2013
4
Overview
Option for SIMATIC WinCC Runtime Advanced and WinCC
Runtime Professional for logging process values and alarms
Logging of process values and alarms supports the acqui-
sition and processing of process data from an industrial plant
or machine. Evaluation of the logged process data provides
information about the operating states of the plant or machine
• Licensing:
- SIMATIC Panels / Multi Panels / Comfort Panels:
No license is required.
- WinCC Runtime Advanced:
One license is required per operator station
- WinCC Runtime Professional:
500 Logging Tags are already included in the basic package
The number of Logging Tags can be increased by means of
additional licenses
Benefits
Alarm and process value logs enable predictive diagnostics,
which avoids downtimes
Early detection of danger and fault conditions
Increase of the product quality and the productivity thanks to
regular analysis of the alarm and process value logs
Application
Transfer of the logs for evaluation and long-term archiving
Detection of recurring error states
Optimization of maintenance cycles
Ensuring the quality standard
Quality assurance and checking the utilization of production
sequences
Documentation of process sequences
Function
Time-controlled as well as manual or process-controlled
swapping out of process data and alarms for long-term
archiving
During runtime, swapped out data are read in and selectively
analyzed using WinCC Runtime Professional
- Presentation and evaluation of archived process data based
on a configurable trend display. Reading of the values is
facilitated by a read line.
- Presentation and evaluation of archived alarms based on a
configurable alarm view.
- User-friendly navigation in the logs
External evaluation of the logs using MS standard tools
Various log types are supported: sequence and circular logs
Logging of process values and alarms on external, Windows-
supported storage media
- SIMATIC Panels and WinCC Runtime Advanced:
CSV files, RDB files, Microsoft SQL Server via ODBC
- WinCC Runtime Professional: Microsoft SQL Server 2005
Powerful standard functions permit user-friendly and flexible
utilization of the logs
ST80_2013_EN_Kap04.book Seite 34 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC Logging
4/35
Siemens ST 80 / ST PC · 2013
Technical specifications
1)
Dependent on memory medium used
2)
Dependent on the Logging Powerpack used for the log tags.
500 log tags are contained in the basis version.
Ordering data
Order No.
1)
One license is required for each operator console. A license is not required
for the engineering system for configuring the runtime option.
2)
Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery
WinCC Logging
for Runtime Advanced
The values specified are maximum
values
Number of logs 100
Archivable data Process values, alarms
Cyclical trigger for archiving
process values (variables) 1 s
Max. number of entries per log
(incl. sequence log) 500 000
1)
Log types Circular logs,
sequence logs (max. 400 per log)
Data storage format CSV (Comma Separated Variable),
RDB (Runtime Data Base),
Microsoft SQL database (database
not included in scope of delivery)
WinCC Logging
for Runtime Professional
The values specified are maximum
values
Number of logs
per single-user station/server 100
Archivable data Process values, alarms
Measured values per second, max. Server/single-user station:
5 000 per sec.
Log tags per single-user station/
server 80 000
2)
Log types Circular log with and without
long-term logging
Data storage format Microsoft SQL 2005 database
SIMATIC WinCC Logging
for Runtime Advanced
1)
6AV2107-0GA00-0BB0
Single license, license key
only on USB stick
SIMATIC WinCC Recipes +
Logging for Runtime Advanced
1)
6AV2107-0HA00-0BB0
Single license per option,
license key only on USB stick
SIMATIC WinCC Logging
for Runtime Professional
1500 Logging Tags
6AV2107-0GB00-0BB0
Single license, license key
only on USB stick
SIMATIC WinCC Logging
for Runtime Professional
5000 Logging Tags
6AV2107-0GD00-0BB0
Single license, license key
only on USB stick
WinCC Logging for Runtime
Professional Powerpack
1500 -> 5000 Logging Tags
6AV2107-2GD00-0BD0
Single license, license key
only on USB stick
WinCC Logging Upgrade for
SIMATIC WinCC Archives V7.0
(10 licenses)
6AV2107-4GX00-0BF0
Single license per option,
license key only on USB stick
Online software delivery (OSD)
2)
WinCC Logging for
Runtime Advanced
1)
6AV2107-0GA00-0BH0
Single license,
license key download only
e-mail address required for
the delivery
WinCC Logging for Runtime
Professional - 1500 Logging Tags 6AV2107-0GB00-0BH0
Single license,
license key download only
e-mail address required for
the delivery
WinCC Logging for Runtime
Professional - 5000 Logging Tags 6AV2107-0GD00-0BH0
Single license,
license key download only
e-mail address required for
the delivery
WinCC Logging for Runtime
Professional Powerpack
1500 -> 5000 Logging Tags
6AV2107-2GD00-0BJ0
Single license,
license key download only
e-mail address required for
the delivery
ST80_2013_EN_Kap04.book Seite 35 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC Audit
4/36 Siemens ST 80 / ST PC · 2013
4
Overview
Option for SIMATIC WinCC Runtime Advanced as well as
SIMATIC Panels for recording operations in an audit trail, and
electronic signature
The audit trail is furnished with a security mechanism that
displays subsequent manipulations.
A user-friendly configuration function, which is included as
standard in WinCC, is used to define the following:
- Which user actions should be recorded in the audit trail
during runtime
- Which important operator actions during execution time
require electronic signature/comments
Available for the following SIMATIC HMI systems:
- Comfort Panels
- Mobile Panels
-TP/OP 277
-MP 277
-MP 377
- WinCC Runtime Advanced
• Licensing:
- A license is required for every operator control unit
(panel or PC).
Benefits
Audit supports the user in meeting special quality require-
ments, e.g.
- Production plant requiring validation according to
21 CFR Part 11 FDA
1)
- In respect of traceability according to EU 175/2002
2)
The entries in the audit trail are uniquely assigned to users.
This means that responsibilities are clearly identifiable.
The audit trail, stored as a CSV file
3)
, can be checked via a
security mechanism to find out if subsequent changes have
been made.
For particularly important user actions, e.g., starting
production or loading new recipes, electronic signatures and
comments can be configured and then called up and logged
during runtime.
1)
The FDA (Food and Drug Administration) is the American public health
body
2)
21 CFR Part 11- law on plant validation
3)
CSV Comma Separated Values
Technical specifications
Ordering data
Order No.
1)
Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery
WinCC Audit
Storage location for Audit Trail when
used on the Panel Plug-in Flash memory card or
via Ethernet in the higher-level PC
Storage location for Audit Trail when
using WinCC Runtime Advanced Local hard disk or
via Ethernet in the higher-level PC
Execution platform
SIMATIC Panels Mobile Panel 277, TP/OP 277
SIMATIC Multi Panels MP 277, MP 377
SIMATIC Comfort Panels all
PC systems SIMATIC WinCC Runtime Advanced
SIMATIC WinCC Audit
for SIMATIC Panels 6AV2107-0RP00-0BB0
Single license,
license key only on USB stick
SIMATIC WinCC Audit
for Runtime Advanced 6AV2107-0RA00-0BB0
Single license,
license key only on USB stick
Online software delivery (OSD)
1)
WinCC Audit for SIMATIC Panels 6AV2107-0RP00-0BH0
Single license,
license key download only
E-mail address required for the
delivery
WinCC Audit
for Runtime Advanced 6AV2107-0RA00-0BH0
Single license,
license key download only
E-mail address required for the
delivery
ST80_2013_EN_Kap04.book Seite 36 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
SIMATIC Logon
4/37
Siemens ST 80 / ST PC · 2013
Overview
Option for connecting SIMATIC Panels and PCs with
SIMATIC WinCC Runtime Advanced as well as WinCC
Runtime Professional to a central user administration.
Creates user administration on a central computer to which
one or more panels or WinCC stations can be connected over
Ethernet.
With each logging-on/off of a user on one of the connected
stations, SIMATIC Logon checks whether a user password has
been created and that the required privileges exist.
SIMATIC Logon for Panels and WinCC Runtime Advanced
All users of the SIMATIC Panels or WinCC Runtime Advanced
stations can be managed plant-wide from a central location
Supports the user in combination with the Audit option in
meeting requirements in accordance with FDA 21 CFR Part 11
and EU178.
Licensing:
SIMATIC Logon (basic license) and SIMATIC Logon Remote
Access (3-pack license) for the connection of 3 panels or
WinCC Runtime Advanced stations to a central user adminis-
tration. Additional stations can be connected by using further
SIMATIC Logon Remote Access licenses (3-pack/10-pack).
SIMATIC Logon for WinCC Runtime Professional
All users of WinCC Runtime Professional can be managed
plant-wide from a central location.
The central user management with SL utilizes Windows
mechanisms and must be installed on all participating
WinCC Runtime Professional stations.
• Licensing:
SIMATIC Logon (basic license) is included in the basic
package of WinCC Runtime Professional
Benefits
Centralized configuration of all access authorizations of a
distributed system avoids unnecessary travel times. Time-
consuming multiple configurations for each individual local
station become unnecessary. Accordingly, users can be
easily configured from a central location.
All access data apply throughout the plant on every
connected station. Additional access data on local
subsystems is no longer necessary.
Design
SIMATIC Logon for Panels and WinCC Runtime Advanced
SIMATIC Logon and SIMATIC Logon Remote Access are
installed on a central station.
The following Runtime stations are connected to the central
station via the Ethernet network:
PCs with WinCC Runtime Advanced
SIMATIC Panels from the 177 series or higher
(with Ethernet interface)
SIMATIC Mobile Panels from the 177 series or higher
(with Ethernet interface)
SIMATIC Multi Panels
SIMATIC Comfort Panels
SIMATIC Logon for WinCC Runtime Professional
The SIMATIC Logon can be used for the central user
management of several WinCC Runtime Professional stations.
Operation in a Windows Workgroup or even in a domain is
possible.
Function
Users receive a unique user ID, user name and password.
This information is encrypted and stored at a central point
(for SIMATIC Logon in the Windows user management).
Functions such as changing the password, automatic log-off
after a predefined time and lockout after several incorrect entries
of a password ensure maximum security of operation.
In addition, SIMATIC Logon allows setting up new users online,
plant-wide and across applications, or blocking of existing
users. SIMATIC Logon also supports electronic signature.
Ordering data
Order No.
1)
SIMATIC Logon V1.5 included in scope of supply of WinCC Runtime
Professional.
SIMATIC Logon V1.5 6ES7658-7BX51-0YA0
Basic license
1)
For panels or WinCC Runtime
Advanced stations, the correspond-
ing number of additional SIMATIC
Logon Remote Access licenses is
required.
No SIMATIC Logon Remote Access
licenses are required for WinCC
Runtime Professional
SIMATIC Logon Upgrade to V1.5 6ES7658-7BX51-0YE0
SIMATIC Logon Remote Access
(3 clients) 6ES7658-7BA00-2YB0
Remote Access for 3 clients;
Single License for 3 SIMATIC Logon
Remote Access clients;
the number of licensed clients is
determined from the sum of the
installed SIMATIC Logon Remote
Access licenses.
SIMATIC Logon Remote Access
(10 clients) 6ES7658-7BB00-2YB0
Remote Access for 10 clients;
Single License for 10 SIMATIC
Logon Remote Access clients;
the number of licensed clients is
determined from the sum of the
installed SIMATIC Logon Remote
Access licenses.
ST80_2013_EN_Kap04.book Seite 37 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC Sm@rtServer
4/38 Siemens ST 80 / ST PC · 2013
4
Overview
Option for SIMATIC WinCC Runtime Advanced plus
SIMATIC Panels for communication between various
SIMATIC HMI systems.
Available for the following SIMATIC HMI systems:
- Comfort Panels
- Mobile Panel 177 PN, Mobile Panel 277
- TP 177B PN/DP, OP 177B PN/DP
- TP 277, OP 277
- MP 177, MP 277, MP 377
- WinCC Runtime Advanced
A SIMATIC HMI system can be used to control or monitor
another system remotely; entry level for client/server configu-
rations for distributed operator stations or for solutions with
head end or control room
Local operation, visualization and data processing are as
possible as plant-wide access to information. Integrated infor-
mation flows ensure an overview of the status of all processes.
Licensing:
The "SIMATIC WinCC Sm@rtServer for Panel" or
"SIMATIC WinCC Sm@rtServer for WinCC Runtime Advanced"
license must be installed on the server HMI device. A license
is not required for the engineering system for configuring the
runtime option.
Note:
When accessing the operator stations via the Sm@rtServer
option, suitable protective measures (including IT security such
as network segmentation) should be taken in order to ensure
safe operation of the system.
You will find more information on the topic of Industrial Security
on the Internet at:
http://www.siemens.com/industrialsecurity
Benefits
Flexible solution for remote access to HMI systems
Quick elimination of malfunctions or downtimes – thus
increasing the productivity – through global access to
machines/plants by the service and maintenance personnel.
Avoidance of on-site service calls.
Operator Station 1 Operator Station 2 Operator Station nMaster Station
Sm@rtServer Sm@rtClient
Industrial Ethernet
G_ST80_XX_00071
...
ST80_2013_EN_Kap04.book Seite 38 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC Sm@rtServer
4/39
Siemens ST 80 / ST PC · 2013
Application
Operator control and monitoring of machines covering large
areas with several operator stations by one operator.
Operator control and monitoring of machine-level HMI
systems from one central station (e.g. head-end station of a
production line or from a control room)
Remote maintenance and servicing of machines/plants over
the Internet/Intranet
Application of the Sm@rtClient concept: Coordinated operation of several operator stations
Use of the Sm@rtClient display: Operator control and monitoring of machine-level HMI systems from one central station
Operator Station 1 Operator Station 2 Operator Station nMaster Station
Sm@rtServer Sm@rtClient
Industrial Ethernet
G_ST80_XX_00071
...
Server 1 Server 2 Server 3 Server 4
Master Control Station Sm@rtClient display
PROFIBUS
Sm@rtServer Sm@rtServer Sm@rtServer Sm@rtServer
Industrial Ethernet
G_ST80_XX_00072
ST80_2013_EN_Kap04.book Seite 39 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC Sm@rtServer
4/40 Siemens ST 80 / ST PC · 2013
Application (continued)
4
Remote operator control and monitoring of SIMATIC HMI systems using
Industrial Ethernet and/or via the Intranet/Internet
Remote operator control and monitoring of SIMATIC HMI systems using
Industrial Ethernet and/or via the Intranet/Internet
lGz
wjVwn
pG
p
{jwVpw
pzkuVkzs
tVy
pzkuVkzs
tVy
G_ST80_XX_00073
jGXaG
vGGG
GGtGpG
l
jGYaG
vGGG
GGpVpG
GGGGb
GGG
Engineering Station
PC/PG
wyvmpi|z
pGl
nz{_WWWW^]
Function
Coordinated operation of several operator stations:
The HMI application and communication with the controller
takes place via the master station. "Sm@rtClients" can be
activated from here in the case of machines/plants with larger
dimensions which require a larger number of HMI devices.
The Sm@rtClients are then provided with access to the master
station and thus to the process. Access procedures guarantee
that only one operator system can actively access the process
at any given time.
Embedded in process screens, a configurable screen object
(Sm@rtClient display) represents the screen of the relevant
HMI system (Sm@rtServer)
Powerful standard functions permit user-friendly and flexible
operation of the display
Remote control of an operating station:
The HMI application and communication with the controller
takes place via the HMI system. Using the Sm@rtServer, the
HMI systems in the machines/systems can be serviced
remotely. An access process ensures that only one operator
(either locally at the machine or remotely via Internet Explorer)
can actively access the process at one time.
Microsoft Internet Explorer V6.0 SP1 or higher is sufficient for
accessing an HMI system.
ST80_2013_EN_Kap04.book Seite 40 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC Sm@rtServer
4/41
Siemens ST 80 / ST PC · 2013
Technical specifications
Ordering data
Order No.
1)
The license must be installed on the Sm@rtServer HMI device. A license is
not required for the engineering system for configuring the runtime option.
2)
Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery
WinCC Sm@rtServer
The values specified are maximum
values
Execution platform
SIMATIC Comfort Panels all
SIMATIC Panels Mobile Panel 177 PN,
Mobile Panel 277,
TP/OP 177B PN/DP,
TP/OP 277
SIMATIC Multi Panels MP 177,
MP 277,
MP 377
PC systems SIMATIC WinCC Runtime Advanced
Number of Sm@rtClients that
can simultaneously connect to
a Sm@rtServer
Comfort Panel
as Sm@rtServer 2 clients for 4" devices
3 clients for 7", 9", 12" and 15"
devices
2 clients for 19" devices
1 client for 22" devices
Mobile Panel 177 PN,
TP/OP 177B PN/DP,
MP 177 as Sm@rtServer
2 clients
Mobile Panel 277,
TP/OP 277,
MP 277 as Sm@rtServer
3 clients for 6" devices
2 clients for 8" and 10" devices
MP 377 as Sm@rtServer 3 clients for 12" devices
2 clients for 15" devices
1 client for 19" devices
WinCC Runtime Advanced as
Sm@rtServer 5 clients
WinCC Sm@rtServer
for SIMATIC Panels
1)
6AV2107-0CP00-0BB0
Single license, license key
only on USB stick
WinCC Sm@rtServer
for Runtime Advanced
1)
6AV2107-0CA00-0BB0
Single license, license key only on
USB stick
Online software delivery (OSD)
2)
WinCC Sm@rtServer
for SIMATIC Panels
1)
6AV2107-0CP00-0BH0
Single license, license key
download only
E-mail address required for
the delivery
WinCC Sm@rtServer
for Runtime Advanced
1)
6AV2107-0CA00-0BH0
Single license, license key
download only
E-mail address required for
the delivery
ST80_2013_EN_Kap04.book Seite 41 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC Server / WinCC Client
4/42 Siemens ST 80 / ST PC · 2013
4
Overview
Option for SIMATIC WinCC Runtime Professional, which
permits the configuration of a powerful client/server system
One of the following operating systems must be available to
install the option on the server: Windows Server 2003,
Windows Server 2003 R2, Windows Server 2008 or
Windows XP Professional. When using Windows XP
Professional, max. 3 clients can be connected.
A number of coordinated HMI stations can be operated in a
single group with networked automation systems
Client/server solution: One server can supply up to
32 connected clients with process and archive data, alarms,
screens and reports
- Requirement: Network connection (TCP/IP) between the
server PC and the connected clients
Licensing:
- A WinCC Runtime Professional license on the server with the
appropriate number of PowerTags and the "WinCC Server for
RT Professional" license.
- The "WinCC Client for RT Professional" license on the clients.
Process bus
nz{_WWW[^Y
TCP/IP
WinCC
Client
SIMATIC S7-400
SIMATIC S7-300
SIMATIC S7-1200
WinCC
Client
WinCC
Client
10092251.fm Seite 42 Freitag, 9. August 2013 8:19 08
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC Server / WinCC Client
4/43
Siemens ST 80 / ST PC · 2013
Benefits
Integrated scalability from the single-user system to the client/
server solution
Considerably expanded quantity structure, relieves the load
on the individual servers, and thus better performance
through the distribution of the overall application or of the
tasks among several servers
Application
In a complex plant, WinCC Runtime Professional can be
configured as a distributed system depending on the require-
ments:
Functional distribution (e.g. alarm server, log server, etc.), or
Distribution corresponding to the physical plant structure
(e.g. body-in-white, paint shop, etc.).
Function
All process data of a WinCC project is stored in different Runtime
databases, e.g. alarms, trend values, etc. These Runtime
databases are located on a central computer, the WinCC Server,
instead on each HMI device. The operator stations, i.e. the
WinCC Clients, then access the WinCC Server.
WinCC Clients and WinCC Server are independent systems.
You can also connect WinCC Clients subsequently. Alternatively,
you can activate and deactivate a project from a WinCC Client.
Ordering data
Order No.
A license is not required for the engineering system for
configuring the runtime option.
1)
Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery
SIMATIC WinCC server
for Runtime Professional 6AV2107-0EB00-0BB0
Single license, license key
only on USB stick
SIMATIC WinCC Client
for Runtime Professional V12 6AV2107-0DB02-0AA0
Single license, license key on USB
stick, software and documentation
on DVD
SIMATIC WinCC Client for
Runtime Professional ASIA V12 6AV2107-0DB12-0AA0
Single license, license key on USB
stick, software and documentation
on DVD
Online software delivery (OSD)
1)
SIMATIC WinCC server
for Runtime Professional 6AV2107-0EB00-0BH0
Single license, license key
download only,
e-mail address required for the
delivery
SIMATIC WinCC Client
for Runtime Professional V12 6AV2107-4DB02-0AK0
Single license, software an
d license key download.
E-mail address required for
the delivery
ST80_2013_EN_Kap04.book Seite 43 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC WebNavigator
4/44 Siemens ST 80 / ST PC · 2013
4
Overview
Option for SIMATIC WinCC Runtime Professional for operating
and monitoring plants over the Internet, company Intranet or
LAN.
Configuration from:
- A web server with SIMATIC WinCC Runtime Professional as
single-user or server version and a web client that permits
operator control and monitoring of a current WinCC Runtime
Professional project using the Internet Explorer.
Licensing:
- A license is required for using the Web server.
- Server-based licenses are available for access to the web
server by 3, 10, 25 or 50 clients.
- Client-based licenses are available for guaranteed access to
the web server (Diagnostics Client)
Note:
When accessing the operator stations via the
WinCC WebNavigator option, suitable protective measures
(including IT security such as network segmentation) should be
taken in order to ensure safe operation of the system.
You will find more information on the topic of Industrial Security
on the Internet at:
http://www.siemens.com/industrialsecurity
~jj
~G
~jj
zjhkhG ~jj
kt
~jjG
RG~uV
kt

nz{_WWW\\]
wyvmpi|z
wyvmpul{
shu
ST80_2013_EN_Kap04.book Seite 44 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC WebNavigator
4/45
Siemens ST 80 / ST PC · 2013
Benefits
Operator control and monitoring across long distances and
on different platforms (PC, local panel, mobile PDA)
Large configurations with up to 50 operator stations
Fast update rates due to event-driven communication
Optimally tailored clients for operating and monitoring,
analysis, service and diagnostics
Acceptance of configuration data for the web, generally
without changes
Minimum maintenance costs due to central software
administration
High security standards and availability
- Support for commonly used security mechanisms
(routers, firewalls, proxy servers)
- WinCC access authorizations and user administration
Support of Microsoft Internet Explorer, including "tabbed
browsing". A new license is not required for separate tabs.
With the WinCC Web Viewer (WinCC Viewer RT), the process
screens can be displayed on the web client independently of
the Internet Explorer. Settings for the client are made on the
client itself. The WinCC Web Viewer can also be used in
conjunction with the MS Terminal Service.
The SIMATIC WinCC WebNavigator can also be operated in
"view only" mode and is thus used as tool for monitoring and
navigating using Internet Explorer or WinCC Web Viewer
(WinCC Viewer RT).
Web server logins and logouts are recorded in the alarm and
audit log.
There is a gadget available for the Windows 7 operating
system in which selected WinCC process screens can be
displayed. No additional WebNavigator license is required for
the gadget. The WebNavigator server can be selected directly
via the gadget.
Security is increased by adjustable automatic logout. If an
automatic logout is to take place, an absolute or inactive time
period can be set.
Highlights:
Multiple Web servers can be accessed from a single Web
client
User-friendly services and tools for distributing customized
objects (controls, files) to web clients can be supplied for use
as an integration platform. These components can then also
be integrated into cross-web/server navigation.
Both Internet Explorer and the supplied, browser-independent
WinCC Web Viewer (WinCC Viewer RT) can be used as a front
end
Access to WebNavigator Server of the WinCC V7.x series.
Application
In addition to the typical use of the WebNavigator in WANs
(Wide Area Networks), the WebNavigator can also be used to
implement especially low-cost applications. This especially
includes applications that have a pronounced distributed
structure (water/wastewater, oil and gas), or in which access to
process information is only sporadic (building management).
The WebNavigator also permits vertical integration, i.e. a
networked IT landscape with integrated data flow between the
planning and operating level of a company. Only a standard
browser is required for direct access to current process infor-
mation.
In addition to the standard WebNavigator licensing, there is the
"Diagnostics Client" with identical functionality but different
licensing. It is especially suitable for the following applications:
Remote diagnostics/operation of several unmanned
WinCC Runtime Professional stations
Central control rooms that monitor several web servers via one
user interface
Maintenance personnel who require guaranteed access to
the server at any time, regardless of the number of users
already logged on to the server. On the server side, only one
WebNavigator Diagnostics Server license or, alternatively, one
Standard WebNavigator license is required.
Design
Licenses for the WebNavigator
The WebNavigator Client software can be installed as many
times as required without the need for a license.
Server-based licensing
- A license is required for using the WebNavigator Server.
- Licenses are available for simultaneous access to the Web
server by 3, 10, 25 or 50 clients.
Diagnostics client licensing
- For cost-optimized access by one or a small number of
WebNavigator clients to numerous Web servers (e.g. for
diagnostic purposes). This client license provides
guaranteed access to Web servers at any time. In respect of
function there is no difference compared with regular
WebNavigator clients and the two can be mixed.
WebNavigator Clients are capable of accessing several different
Web Servers.
Thin client solutions
The WebNavigator can also run under Windows Server 2003 or
Windows Server 2008 terminal services. A Windows Server 2003
or Windows Server 2008 (or higher) operating system is
required. This makes it possible to connect SIMATIC Thin Clients
as visualization stations to WinCC Runtime Professional, for
example.
For this purpose, the Windows terminal services must be
installed on the PC on which the Web Client is installed.
A Windows Server 2003 or Windows Server 2008 (or higher)
operating system is required. Up to 25 thin clients can be
connected to one terminal server.
Applications:
Mobile devices
Handhelds
Rugged on-site visualizations
ST80_2013_EN_Kap04.book Seite 45 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC WebNavigator
4/46 Siemens ST 80 / ST PC · 2013
Design (continued)
4
Hybrid configuration
System requirements: WinCC WebNavigator – Server V12
Windows 7 SP1 (32- and 64-bit) Business, Enterprise and
Ultimate (max. 3 Clients)
Windows XP Professional Service Pack 3 (max. 3 clients)
Windows Server 2003 SP2
Windows Server 2008 SP2 32-bit
Windows Server 2008 R2 SP1 64-bit
Internet Explorer V7.0, V8.0, V9.0
Microsoft SQL Server 2008 R2 SP1 32-bit
(included in the WinCC product delivery)
•WinCC Basic System V12
System requirements: WinCC WebNavigator – Client V12
Internet Explorer 7, IE 8, IE9
System requirements: WinCC WebNavigator – Server V11
Windows 7 (32-bit) Business, Enterprise and Ultimate
(max. 3 clients)
Windows XP Professional Service Pack 2 (max. 3 clients)
Windows Server 2003 SP2 and Windows Server R2 SP2
Windows Server 2008
Internet Explorer 7 as well as Internet Explorer 8
Microsoft SQL Server 2005 SP2 (scope of supply of WinCC)
WinCC Runtime Professional V11
System requirements: WinCC WebNavigator – Client V11
Internet Explorer 7 as well as Internet Explorer 8
Function
WinCC Professional makes setting up and configuring a
WebNavigator server very easy. WinCC process screens to be
visualized via the Internet are created as usual in WinCC Profes-
sional and the web access is activated via a process screen
option. To display WinCC process screens on the web client, the
Microsoft Internet Explorer or browser is used independent of
the supplied WinCC Web Viewer (WinCC Viewer RT).
The operator on the Web Client is integrated in the central
WinCC user administration and can operate and monitor the
system according to the configured access rights.
The WebNavigator supports all standard security mechanisms
that can be used for applications on the Internet, e.g. routers,
firewalls and proxy servers.
Ordering data
Order No.
A license is not required for the engineering system for configuring the
runtime option.
1)
Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery
SIMATIC WinCC WebNavigator
for Runtime Professional
Single license, license key
only on USB stick
• 3 clients, runtime software 6AV2107-0KD00-0BB0
• 10 clients 6AV2107-0KF00-0BB0
• 25 clients 6AV2107-0KH00-0BB0
• 50 clients 6AV2107-0KK00-0BB0
• 100 clients 6AV2107-0KM00-0BB0
• 150 clients 6AV2107-0KP00-0BB0
SIMATIC WinCC WebNavigator
for Runtime Professional
Powerpacks
Single license, license key
only on USB stick
• From 3 to 10 clients 6AV2107-2KF00-0BD0
• From 10 to 25 clients 6AV2107-2KH00-0BD0
• From 25 to 50 clients 6AV2107-2KK00-0BD0
• From 50 to 100 clients 6AV2107-2KM00-0BD0
• From 100 to 150 clients 6AV2107-2KP00-0BD0
SIMATIC WinCC WebNavigator
Diagnostics Server/Client
Single license, license key only on
USB stick
• WinCC WebDiagnostics Server
for Runtime Professional, Runtime
software
6AV2107-0KR00-0BB0
• WinCC WebDiagnostics Client for
Runtime Professional, Runtime
software
6AV2107-0KT00-0BB0
New type of delivery
Online software delivery (OSD)
1)
WinCC WebNavigator
for Runtime Professional
Single license, license key
download only,
e-mail address required for
the delivery
• 3 clients 6AV2107-0KD00-0BH0
• 10 clients 6AV2107-0KF00-0BH0
• 25 clients 6AV2107-0KH00-0BH0
• 50 clients 6AV2107-0KK00-0BH0
• 100 clients 6AV2107-0KM00-0BH0
• 150 clients 6AV2107-0KP00-0BH0
WinCC WebNavigator for
Runtime Professional
Powerpacks
Single license, license key
download only,
e-mail address required for
the delivery
• 3 to 10 clients 6AV2107-2KF00-0BJ0
• 10 to 25 clients 6AV2107-2KH00-0BJ0
• 25 to 50 clients 6AV2107-2KK00-0BJ0
• 50 to 100 clients 6AV2107-2KM00-0BJ0
• 100 to 150 clients 6AV2107-2KP00-0BJ0
WinCC WebNavigator
Diagnostics Server/Client
Single license, license key
download only,
e-mail address required for
the delivery
• WinCC Web Diagnostics Server
for Runtime Professional 6AV2107-0KR00-0BH0
• WinCC Web Diagnostics Client
for Runtime Professional 6AV2107-0KT00-0BH0
ST80_2013_EN_Kap04.book Seite 46 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC DataMonitor
4/47
Siemens ST 80 / ST PC · 2013
Overview
The WinCC DataMonitor is used for displaying and evaluating
current process states and historical data on office PCs using
standard tools such as Microsoft Internet Explorer or Microsoft
Excel. In doing so, the DataMonitor client is supplied by a Web
server with current and historic process data and alarms. All
staff ranging from machine operators to corporate managers
can use the DataMonitor to obtain information.
DataMonitor is a suite of Internet-capable tools:
-Process Builder
Tool exclusively for monitoring and navigating via
WinCC Runtime Professional screens using Internet Explorer
(view only) or the WinCC Web Viewer (WinCCViewerRT)
-Excel Workbooks
Logging tool that integrates WinCC Runtime Professional
Archive and online values into Microsoft Excel and supports
online analysis
-Published Reports
Event or time-driven implementation of Excel or PDF reports
for the output of process data and analysis results
-Webcenter
Individual configuration of Internet pages and summary of
information within a portal with reference to WinCC Runtime
Professional applications
-Trends and Alarms
(tables and graphs) are preconfigured Webcenter pages
DataMonitor does not require manual client installation
because it loads the required components from the web
server.
There is no installation required on the client for the Webcenter
and Trends and Alarms functions.
• Licensing:
- Licenses for access by 1, 3, 10, 25, or 50 DataMonitor clients
are available.
- Any combination of DataMonitor and WebNavigator licenses
can be used in an application.
Note:
When accessing the operator stations via the
WinCC DataMonitor option, suitable protective measures
(including IT security such as network segmentation) should
be taken in order to ensure safe operation of the system.
You will find more information on the topic of Industrial Security
on the Internet at:
http://www.siemens.com/industrialsecurity
~jj
~G
~jj
zjhkhG ~jj
kt
~jjG
RG~uV
kt

nz{_WWW\\]
wyvmpi|z
wyvmpul{
shu
ST80_2013_EN_Kap04.book Seite 47 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC DataMonitor
4/48 Siemens ST 80 / ST PC · 2013
4
Benefits
Information can be compiled online individually during
runtime via the Internet/Intranet.
Efficiently monitor and analyze production lines.
- Display and evaluation of current process states and
historical data on remote office PCs with standard tools such
as Microsoft Internet Explorer or Excel.
- Easy access to production data via the Intranet or Internet
- Quick ascertainment of the production situation
Easily collect and distribute information.
- Automated report creation
- No additional configuration effort through direct use of
screens from the WinCC project
- No training required for standard products
- Easy exchange of configuration data
Substantiate decisions with reports.
- Evaluation via ready-made templates for special analyses
of the business processes (e.g. reports, statistics)
- Display bottlenecks transparently
- Individual views for user and situation
- Relative and absolute timeframe for information generation
View production status anywhere and anytime.
- Individual views of information in production
- View the process and system operation
- Historical data can be compiled online individually
Highlights:
With the Webcenter function, WinCC Runtime Professional
archive tags can be accessed without changing the configu-
ration system.
Dedicated Internet pages can be created for displaying data
with the Webcenter. For this purpose, the following tools,
which can be integrated in the Internet sites, are available.
- Bar chart, pie chart, trend curve display
- Process value table and statistics functions for the process
values
- Alarms, hit list for alarms
- Message text display for individual message texts, message
display, selection list of created reports,
- Links to internal and external pages
- Display of graphics in jpg format
- Representation of the WinCC Runtime Professional process
screens
The analyses can be made with relative or absolute time
specification. This enables comparisons of identical time
periods on different days.
Reports generated with Excel or with WinCC Professional can
be made available on the DataMonitor server or e-mailed
automatically to the relevant group of people based on time
intervals or triggered by events.
Connections to WinCC Runtime Professional and to swapped
out archives can be established
Support of Microsoft Internet Explorer version, including
"tabbed browsing".
Function
All tools are fully Internet-compatible and, therefore, support
access via any type of connection (LAN, GSM, radio, modem,
Internet, etc.).
All popular security mechanisms such as login/password,
firewalls, encryption, etc. are supported.
Users can combine the available tools at will. Licensing only
takes into account simultaneous access to one Web server.
For display purposes, screens from the WinCC project can be
used or special overview displays configured. Animations,
scripts, navigation and access rights remain valid.
The WinCC DataMonitor supports a display function only.
Company-wide Excel reports, which contain historical and
current process values, can be stored centrally for general
access (reports, statistics). However, local queries to meet
individual requirements can be compiled and executed
online. Plot and tabular representation are supported for
archive data already swapped out.
Data can be automatically entered into created report
templates and distributed by e-mail.
Pre-made elements make the assembly of individual web
pages easier for evaluating information.
Individual information compilation on one or more Internet
pages with the option of branching to other detail pages.
Pre-made Internet pages for trend and alarm display enable
an ad-hoc entry to Internet data evaluation.
An higher-level navigation feature provides a common
framework for the various tools.
Enhanced user management for the web center in order to
assign individual Internet pages and created reports to
specific user groups.
A search function facilitates the management of connections
to the WinCC server.
Swapped out archives can be connected and evaluated in the
DataMonitor WebCenter.
Excel reports created offline can be loaded onto the
DataMonitor server and are thus made available to selected
user groups or for automatic distribution.
ST80_2013_EN_Kap04.book Seite 48 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC DataMonitor
4/49
Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
A license is not required for the engineering system for config-
uring the runtime option.
1)
Current information and availability regarding the new delivery package
can be found at: http://www.siemens.com/tia-online-software-delivery
SIMATIC WinCC DataMonitor
for Runtime Professional
Single license, license key
only on USB stick
1 client 6AV2107-0LB00-0BB0
3 clients 6AV2107-0LD00-0BB0
10 clients 6AV2107-0LF00-0BB0
25 clients 6AV2107-0LH00-0BB0
50 clients 6AV2107-0LK00-0BB0
SIMATIC WinCC DataMonitor
for Runtime Professional
Powerpacks
Single license, license key
only on USB stick
• From 1 to 3 Clients 6AV2107-2LD00-0BD0
• From 3 to 10 Clients 6AV2107-2LF00-0BD0
• From 10 to 25 Clients 6AV2107-2LH00-0BD0
• From 25 to 50 Clients 6AV2107-2LK00-0BD0
Online Software Delivery (OSD)
1)
SIMATIC WinCC DataMonitor
for Runtime Professional
Single license, license key
download only,
e-mail address required for
the delivery
• 1 client 6AV2107-0LB00-0BH0
• 3 clients 6AV2107-0LD00-0BH0
• 10 clients 6AV2107-0LF00-0BH0
• 25 clients 6AV2107-0LH00-0BH0
• 50 clients 6AV2107-0LK00-0BH0
SIMATIC WinCC DataMonitor
for Runtime Professional
Powerpacks
Single license, license key
download only,
e-mail address required for
the delivery
• From 1 to 3 clients 6AV2107-2LD00-0BJ0
• From 3 to 10 clients 6AV2107-2LF00-0BJ0
• From 10 to 25 clients 6AV2107-2LH00-0BJ0
• From 25 to 50 clients 6AV2107-2LK00-0BJ0
ST80_2013_EN_Kap04.book Seite 49 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC (TIA Portal) options
WinCC ControlDevelopment
4/50 Siemens ST 80 / ST PC · 2013
4
Overview
You use the ControlDevelopment option to create your own
.net controls for controlling and monitoring processes. You can
use the controls in screens for WinCC Runtime Advanced and
WinCC Runtime Professional. You create the controls based
on the standard controls from Visual Studio 2005/2008
Professional .net.
Application examples:
Special trend views
Own recipe managements
Complex display objects
Benefits
The ControlDevelopment option enables user-specific software
solutions based on a proven building block principle:
Lower development overhead by using standards
(Visual Studio 2005/2008 Professional .net)
Very short "Time-to-Market" resulting in a competitive
advantage
Utilization of tried components and proven industrial function-
ality
The development of proprietary controls for WinCC Runtime
Advanced and WinCC Runtime Professional does not require
expensive, special hardware.
Ordering data
Order No.
1)
Current information and availability regarding the new delivery package
can be found at:
http://www.siemens.com/tia-online-software-delivery
More information
Further information can be found in the Internet at:
http://www.siemens.com/tia-portal
WinCC ControlDevelopment V12
• Runtime license,
single license, software
and documentation on CD
6AV2107-0TA02-0DA8
• Runtime software,
single license, software download
(e-mail address required for the
delivery)
1)
6AV2107-0TA02-0DG8
ST80_2013_EN_Kap04.book Seite 50 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
Software for energy management
Software for energy management
4/51
Siemens ST 80 / ST PC · 2013
Overview
SIMATIC offers numerous reasons for corporate energy
management in industrial plants.
However, there is one in particular:
It makes an important contribution towards improving plant
productivity. This results in enhanced competitiveness. Energy
management with SIMATIC makes energy flows transparent in
production plants. This supports the analysis and derivation of
energy saving potential.
The result:
Permanently increased efficiency, higher productivity and an
improved cost situation.
ST80_2013_EN_Kap04.book Seite 51 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
Software for energy management
SIMATIC B.Data
4/52 Siemens ST 80 / ST PC · 2013
4
Overview
SIMATIC B.Data V5.3 SP2 Energy Management System
SIMATIC B.Data is a modular, cross-sector energy management
system for industrial firms.
Benefits
The option SIMATIC B.Data forms the basis of a cost-effective
energy management system for reducing energy costs and
increasing energy efficiency, and it confers the following
immediate benefits:
It creates company-wide transparency, thanks to continuous
energy balancing and materials balancing for the power
generation systems and loads
It allows energy costs to be allocated according to the costs-
by-cause principle and permits transfer to the billing system
(e.g. SAP R/3 CO)
It generates characteristic values for well-informed sugges-
tions for increasing the efficiency of power generation systems
and loads
It provides planning reliability thanks to production-related
load and demand forecasts
It supports purchasing with cost-optimized energy
procurement
It fulfills the legal obligations for monitoring and reporting on
greenhouse gas emissions (CO2 emissions)
It relieves personnel of extra work through automatically
updating internal and external energy reports
It supports customers in the continuous improvement of
energy efficiency (e.g. ISO 50001) by integrated project
management for energy efficiency measures
Automation
field level
Forecast
Energy forecast
Budget planning
Energy schedule
Energy purchase schedule
Specifications for Load manage-
ment
Fault/alarm management
Alarms/messages
Remote alarms (text message)
Interfaces to lower-level systems Meters/
measuring
devices
Process
control/
building
management
systems
PLCs Circuit-
breakers
Mobile
data
acquisition
Energy purchase
Purchase support
Scenario calculator
Emission
CO2 emission monitoring
Wastewater disposal
Operation and control system
Central detection
Plant visualization
Data processing and archiving
Energy reporting system
Analysis and reporting
Workflow system
Intranet/Internet viewer
Load management
Load shedding
Load control
Connection of external systems
Facility management
ERP (e.g. SAP R/3)
Maintenance management
Energy planning and procurement Energy controlling Monitoring and reporting
Energy accounting
Cost center allocation
Evaluation/invoicing
Energy and material balance
KPI calculation
Production allocation
Energy management – Company portal
B.Data
WinCC
G_ST80_XX_00379
ST80_2013_EN_Kap04.book Seite 52 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
Software for energy management
SIMATIC B.Data
4/53
Siemens ST 80 / ST PC · 2013
Design
SIMATIC B.Data V5.3 SP2 Basic System
The B.Data Basic System is available in variants for 100, 500,
1 000 and 30 000 tags and comprises the following compo-
nents:
A B.Data acquisition component (WinCC, OPC, etc.)
A B.Data Client
•B.Data Mobile
•ERP interface
Reporting, Trender, Visu, document management, Matrix, KPI,
Profile
SIMATIC B.Data Software Update Service (SUS)
For each B.Data Basic System there is a corresponding SUS
(Software Update Service), which is dependent on the number
of tags. The SUS is valid for 1 year. The contract is automatically
extended by 1 more year unless canceled 3 months prior to
expiration.
SIMATIC B.Data V5 Expansions
The scope of B.Data can be extended by purchasing add-on
packages:
B.Data Web Server
B.Data Client
B.Data Energy Forecasting and Planning
B.Data Acquisition Component
Function
Acquisition and pre-processing of energy and operating
data from WinCC
In addition to an interface to WinCC, SIMATIC B.Data also
offers the latest interface standards such as OPC, ODBC,
ASCII, or XML
Preprocessing of energy data in a real-time calculation core
that can be freely modeled including a formula editor for
defining and configuring new calculation functions (heat
calculations for boilers, quality for cogeneration plants, etc.)
B.Data Mobile for mobile recording of energy data including
route planning for meter reading operations
Management and analysis of energy data
Automatic plausibility check and generation of simulated
values
Long-term archive with versioning, compression and consoli-
dation functions
Measured value editor for entering and processing energy
and operating values
Trender for presenting up-to-date (online) and historical load
curves (trends), also for setpoint/actual value analyses
Energy management dashboards for creating cross-company
transparency through visualization of parameters and display
of Sankey diagrams.
ST80_2013_EN_Kap04.book Seite 53 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
Software for energy management
SIMATIC B.Data
4/54 Siemens ST 80 / ST PC · 2013
Function (continued)
4
Energy and material balance
Freely parameterizable balancing of the energy flows of various
media such as electricity, heat, gas, steam, and emissions
(CO2) in the B.Data Plant Explorer
Calculation of characteristic values (KPIs, efficiency coeffi-
cients, etc.) with direct reference to production (batches,
quantities, etc.).
Energy accounting (costs and revenue accounting)
Calculation and allocation/assignment of energy costs to plants
and/or customers/cost units in accordance with the costs-by-
cause principle. The bottom up (measurement) and top down
(allocation) procedures are supported here
Flexible modeling of the hierarchic accounting structures in
the Plant Explorer
Tariff allocation of quantities, flexible price assessment with
tariff and price time series
Transfer of costs/revenues to the ERP system
(e.g. SAP R/3 CO)
Energy planning
Generation of requirement forecasts based on production-
dependent factors (production planning) and basic load
profiles (typical days)
Generation of energy schedules for registering with the
energy suppliers. Energy reporting
Freely parameterizable report generator for creating
balances, protocols, shift logs, bills
Fully automated reporting with task management, e-mail
dispatch and document management
B.Data Intranet/Internet viewer (web client) for company-wide
viewing of reports and results
Information about discrepancies from specified parameters
through KPI warning system
Losses
Counter 1 Counter 3
Counter 2
Accounting area
(e.g. Cost center)
Consumption area
(e.g.: Building 1)
Factors are based on:
• Numbers of
employees
Area data
Allocation formula
• etc.
100% Distribution
ensured
Consumption area
(e.g.: Building 2)
G_ST80_XX_00380
1 ... n
10% 90%
75% 25%
20% 80%
ST80_2013_EN_Kap04.book Seite 54 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
Software for energy management
SIMATIC B.Data
4/55
Siemens ST 80 / ST PC · 2013
Technical specifications
1)
If an acquisition computer is installed on a WinCC system,
these requirements must also be complied with.
2)
The SIMATIC B.Data V5.3 Basic System is delivered with an Oracle
Database Standard Edition Embedded. For larger quantity frameworks
(as of 250 million stored measured values), you need Oracle Database
Enterprise Edition with Partitioning Option, which must be ordered
separately from Oracle.
3)
The SIMATIC B.Data system for connection to the PCS 7 must always be
installed on a separate PC.
More information
Further information can be found on the Internet at:
www.siemens.com/simatic-bdata
Ordering data
Order No.
1)
The SIMATIC B.Data V5.3 Basic System is delivered with an Oracle
Database Standard Edition Embedded. For larger quantity frameworks
(as of approx. 250 million stored measured values), you need Oracle
Database Enterprise Edition with Partitioning Option, which must be
ordered separately from Oracle.
2)
The SUS contract runs for 1 year. The contract is automatically extended
by a further year unless canceled 3 months prior to expiration.
3)
B.Data expansions can also be used with B.Data V5.2 (SP1).
4)
The upgrades are delivered without Oracle Database Standard Edition
Embedded.
5)
The trial DVD can also be used to upgrade V5.3 SP1 -> V5.3 SP2.
SIMATIC B.Data V5.3 SP2
2)
Operating system Windows Server 2003 SP2 32 bit
Eng./Ger.
Windows Server 2008 Std. Edition
32 bit Eng./Ger.
Windows Server 2008 R2 Eng./Ger.
Windows XP Professional SP3
32 bit Eng./Ger.
Windows 7 Professional/Ultimate
32 bit/64 bit Eng./Ger.
Minimum of 2 GB RAM
Interface In addition to an interface to WinCC,
B.Data also offers the latest inter-
face standards, such as OPC,
ODBC, ASCII and XML.
WinCC versions
1)
• SIMATIC WinCC V7.0 SP3, V7.2
• SIMATIC WinCC RT Professional
V11 SP2, V12
PCS 7 versions
3)
• SIMATIC PCS 7 V8.0 SP1
SIMATIC B.Data V5.3 SP2
Basic System
In the basic system of B.Data, the
following components are already
included:
One B.Data acquisition component
(WinCC, OPC, etc.),
1 B.Data client, B.Data Data Mobile,
ERP interface, Reporting, Trender,
Visu, document management,
Matrix, KPI, Profile
• Basic system, 100 tags
1)
6AV6372-1DF05-3AX0
• SUS for 100 tags
2)
6AV6372-1DF00-0AL1
• Basic system, 500 tags
1)
6AV6372-1DF05-3BX0
• SUS for 500 tags
2)
6AV6372-1DF00-0BL1
• Basic system, 1 000 tags
1)
6AV6372-1DF05-3CX0
• SUS for 1 000 tags
2)
6AV6372-1DF00-0CL1
• Basic system, 30 000 tags
1)
6AV6372-1DF05-3DX0
• SUS for 30 000 tags
2)
6AV6372-1DF00-0DL1
SIMATIC B.Data V5 Powerpack
• Basic system, Powerpack
1)
Tag upgrade by 1 level 6AV6372-1DF05-3XX0
• SUS and support contract
for Powerpack
2)
6AV6372-1DF00-0XL1
SIMATIC B.Data V5.3 Trial License 6AV6372-1DF15-3AX0
Basic System, 90 days
5)
SIMATIC B.Data V5 Expansions
3)
The functional scope of B.Data can
be expanded with the following
packages.
SIMATIC B.Data Web Server
• incl. 3 web clients 6AV6372-1DF25-2AX0
• incl. 20 web clients 6AV6372-1DF25-2BX0
SIMATIC B.Data Client 6AV6372-1DF35-2AX0
SIMATIC B.Data
Prognosis & Planning 6AV6372-1DF45-2AX0
SIMATIC B.Data
Acquisition Component 6AV6372-1DF55-2AX0
SIMATIC B.Data upgrades
• SIMATIC B.Data 100 tags,
upgrade V5.2 -> V5.3 SP2
4)
6AV6372-1DF05-3AX4
• SIMATIC B.Data 500 tags,
upgrade V5.2 -> V5.3 SP2
4)
6AV6372-1DF05-3BX4
• SIMATIC B.Data 1 000 tags,
upgrade V5.2 -> V5.3 SP2
4)
6AV6372-1DF05-3CX4
• SIMATIC B.Data 30 000 tags,
upgrade V5.2 -> V5.3 SP2
4)
6AV6372-1DF05-3DX4
ST80_2013_EN_Kap04.book Seite 55 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
Software for energy management
SIMATIC powerrate
4/56 Siemens ST 80 / ST PC · 2013
4
Overview
SIMATIC powerrate, as an option for WinCC / PCS 7, ensures
transparency in energy consumption from the infeed to the load.
SIMATIC powerrate is used in all sectors in which WinCC or
PCS 7 are deployed and energy efficiency considerations play
a major role.
Total integration into WinCC or PCS 7 means that there is no
need for a special system environment. Predefined modules and
symbols give you the assurance of building on tested product
components, with interfaces that support customized
expansion.
SIMATIC powerrate therefore provides a solution that you can
use to obtain an overview of the energy consumption of a plant
easily and cost-effectively through integration in an existing
SIMATIC SCADA system.
Benefits
Identification of energy-intensive equipment and processes to
develop measures for improving energy efficiency.
Comparison of consumption profiles for more efficient
processes.
Optimization of the company according to energy parameters,
based on an evaluation of consumption and costs.
Compliance with the contractually agreed power limits, thus
preventing higher power supply costs or penalty payments.
Integration of the 7KM PAC3200/4200 measuring devices for
a clear overview of selected measured values and alarms.
Integration of switches with an overview of the switch status
and the switching possibilities.
Accurate assignment and comparison of the consumption
data of specific work processes or batches
Design
SIMATIC powerrate comprises the following components:
Blocks for acquiring and conditioning energy data
Faceplates for displaying and editing energy data
Blocks for implementing load management (calculating the
trend, monitoring the limit, releasing/inhibiting loads), batch-
related consumption recording and for integrating measuring
instruments and switches
Additional blocks – for example, for time synchronization, data
backup, data exchange with archives
Faceplates for displaying results and entering values
(e.g. for configuration, or manually measured values)
Excel-based reports for allocating energy data to cost
centers, for batch-related evaluation and for determining and
displaying the load duration curve
Exporting data to Excel
ST80_2013_EN_Kap04.book Seite 56 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
Software for energy management
SIMATIC powerrate
4/57
Siemens ST 80 / ST PC · 2013
Function
Acquiring and conditioning energy data
Using ready-to-use function blocks, energy data can be
acquired by any PROFIBUS-capable devices. The data can be
input to the function blocks in the form of counter pulses, count
values or power values. Count values can also be entered
manually.
From this data, the function block calculates the power averages
and the work values for a predefined period. This calculated
data is subsequently saved in the WinCC archive. In addition,
a final value forecast is extrapolated for the power values for
each period.
A sample function (heat calculation) that can be adapted to the
needs of the customer at any time by means of open interfaces
has been implemented for the purpose of visualizing customized
calculations.
Data from manually read counters can be entered directly into
the system and used for further analysis. Absolute numerical
values (entry of an absolute value instead of the difference from
the previous value) can also be recorded and used in further
processing.
The up-to-date, acquired energy data is displayed as power
averages/work values for each time interval (total value for the
previous interval, current value of the current interval, extrapo-
lated value for the end of the current interval). A load trend
display enables analysis of archived energy data as well as its
representation in tables.
The archived data can be exported to Excel directly from WinCC
using the export functions. The exported energy data can also
be included in further customized processing. WinCC tools can
be used to access the data from the WinCC archive.
For this purpose, selected energy data is read from archives
(Tag Logging archive, user archives) from the WinCC Runtime
database; using Microsoft Excel the following reports can then
be generated:
Cost center report
Here the consumption can be allocated to different cost
centers and the costs can be calculated on the basis of
predefined tariffs. The results can be output by means of
2 reports in the form of tables or diagrams.
Load duration curve
An analysis is carried out on the basis of the archived power
averages to establish how often a certain power average has
occurred in a given period. It can be quickly detected from
this characteristic curve whether temporary power peaks exist
which can represent a possible starting point for cost savings
by means of load management.
Batch report
This is used to allocate consumption to batches, whereby the
data can be presented in chronological order or in order of
batch name.
The generation of exports or reports can be activated manually
or automatically time-controlled (daily, weekly or monthly). Data
access and report generation can also take place via a separate
"office" PC; which enables the WinCC installation and the "office"
applications to be distributed across different PCs.
Contractually agreed power limits (in the case of electricity,
normally the 15-minute average power value) must be observed,
otherwise significantly higher supply prices or even penalty
payments may become due to the energy supply company.
The load management feature of SIMATIC powerrate carries out
cyclic trend calculations in order to issue warnings/alarms if
violation of the limit is likely and to switch off loads in accordance
with the given configuration should this be required. If a limit is
exceeded despite this, the latest load management data is
archived to enable future evaluation or analysis.
To prevent unnecessary switching operations, numerous param-
eters are available for adapting the load management to the
current process conditions - and all this can be done easily and
conveniently via the faceplate.
For loads that are distributed over different PLCs, SIMATIC
powerrate contains appropriate PLC-to-PLC communication
blocks which can be used to integrate these loads into the load
management system. Load management is scalable, according
to the maximum number of loads to be integrated or monitored,
for up to 10, 25, 50, 75 or 100 loads. Load management can be
performed for different media (e.g. electricity, gas) simultane-
ously.
A batch comprises all the units of a product that have been
produced in one production cycle, i.e. under identical condi-
tions. Batch-related consumption recording allows accurate
recording of energy consumption for each batch. Batch-related
consumption recording is possible for five types of energy each
with up to 10 loads. Appropriate reports can be generated for
analysis of the data (see also the batch report).
If the 7KM PAC3200/PAC4200 measuring devices are
integrated, selected measured values can be displayed and
alarms (current, voltage, pulse frequency too high) can be
generated from the digital status information and displayed.
Switch integration via digital inputs/outputs (DI/DO) supports
display of the switch status (On, Off, tripped, unplugged).
With the appropriate authorization, switching is also possible via
the faceplate. Switching takes place in a 2-step operation
(switch command is issued, followed by a prompt for repeated
confirmation; the switch command is not forwarded to the switch
until confirmation has been received).
Support for the WinCC Web Navigator option also makes the
powerrate functionality possible via the web.
To avoid data loss in the event of a communication fault, the data
is stored temporarily in a circulating buffer on the S7.
ST80_2013_EN_Kap04.book Seite 57 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
Software for energy management
SIMATIC powerrate
4/58 Siemens ST 80 / ST PC · 2013
4
Technical specifications
Ordering data
Order No.
1)
For operation on a WinCC/PCS 7 OS single-user workstation or server
and any number of automation systems. When using additional
WinCC/PCS 7 OS single-user stations/servers, one license is required
per WinCC/PCS 7 OS single-user station/server.
More information
Further information can be found on the Internet at:
http://www.siemens.com/simatic-powerrate
Important information on the use of SIMATIC powerrate is
available on the Internet at:
http://support.automation.siemens.com/WW/view/en/48204134/
133200
SIMATIC powerrate V4.0 SP1
Hardware requirements
SIMATIC powerrate can be used in
the PCS 7 or WinCC SCADA environ-
ments. For installation, the respective
hardware requirements of the following
products apply:
•PCS 7
STEP 7 and WinCC SCADA
Released CPUs - SIMATIC powerrate
is released in the PCS 7 environment
for
S7-400 CPUs supported
by PCS 7
WinAC RTX 2010
Released CPUs - SIMATIC powerrate
is released in the WinCC SCADA
environment for
• S7-400
• S7-300
- SIMATIC S7 CPU 319-3 PN/DP
V2.5 and higher
- SIMATIC S7 CPU 317-2 PN/DP
V2.6 and higher
- SIMATIC S7 CPU 315-2 PN/DP
V3.1 and higher
SIMATIC ET 200S IM151-8 PN/DP
CPU V3.2 and higher
WinAC RTX 2010
Software requirements
You can use SIMATIC powerrate in
the PCS 7 or WinCC SCADA environ-
ments. For installation, the respective
software requirements of the following
products apply:
•PCS 7
STEP 7 and WinCC SCADA
The library is released for the following
PCS 7 versions SIMATIC PCS 7 V8.0 with
Update 1 (Europe & ASIA)
• SIMATIC PCS 7 V7.1 SP3
The library is released for the following
WinCC version with the corresponding
versions of STEP 7
• SIMATIC WinCC V7. 0 SP3,
SP3 with Update 1
(Europe & ASIA)
For use with WinCC V7.0 SP3, the
following installations are required • WinCC minimum installation
- Basic Process Control
- User archives for load manage-
ment and batch-oriented energy
acquisition
WinCC add-on
"AS-OS Engineering"
For the use of SIMATIC powerrate
V4.0, WinCC must execute in
integrated mode with STEP 7.
• SIMATIC NET
STEP 7
powerrate Reports has been released
for the following versions Microsoft Excel 2003
Microsoft Excel 2007
Microsoft Excel 2010
SIMATIC powerrate V4.0 SP1 ES +
OS Runtime
1)
6AV6372-1DE04-0AX0
Also included are
• License for user/archive
• PAC3200 function block library
for WinCC
• Block library PAC3200,
3WL/3VL for PCS 7
SIMATIC powerrate V4.0 SP1
upgrade 6AV6372-1DE04-0AX4
Upgrade V3.0 SP1 to V 4.0 SP1,
ES + OS-RT
1)
SIMATIC powerrate V4.0 SP1
update 6AV6372-1DE04-0AX3
Update V4.0 to V 4.0 SP1
SIMATIC powerrate V4.0 SP1
trial license 6AV6372-1DE04-0AX7
Limited 30-day
ES + OS Runtime license
ST80_2013_EN_Kap04.book Seite 58 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible HMI system
4/59
Siemens ST 80 / ST PC · 2013
Overview
SIMATIC WinCC flexible ES engineering software
Family of configuration systems with WinCC flexible Micro/
Compact/Standard/Advanced for SIMATIC operator panels,
the HMI part of SIMATIC C7 as well as for the PC-based visual-
ization software WinCC flexible Runtime
Runs under Windows XP Professional /
Windows 7 Professional, Ultimate, Enterprise
Can be expanded by the option
"WinCC flexible /ChangeControl" for
version management and change logging
SIMATIC WinCC flexible Runtime visualization software
Modular PC-based HMI solution for single-user systems
directly at the machine (further development of
ProTool/Pro RT)
Runs under Windows XP Professional /
Windows 7 Professional, Ultimate, Enterprise
Basic package for visualization, reporting and logging; can be
expanded by implementing option packages
Flexible expansion possible with VB scripts and customized
ActiveX controls created with OPP (Open Platform Program)
Can be integrated into automation solutions based on TCP/IP
networks
Expanded service concepts with remote operation,
diagnostics and administration over the intranet and Internet
in combination with email communication
ST80_2013_EN_Kap04.book Seite 59 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible ES
4/60 Siemens ST 80 / ST PC · 2013
4
Overview
Uniform family of engineering tools for configuration
SIMATIC HMI Operator Panels, the operator control part of
SIMATIC C7 units, SIMOTION/SINUMERIK Panel PCs as well
as the PC-based visualization software WinCC flexible
Runtime.
Runs under Windows XP Professional /
Windows 7 Professional, Ultimate, Enterprise
Current version:
- SIMATIC WinCC flexible 2008 SP3 Micro
- SIMATIC WinCC flexible 2008 SP3 Compact
- SIMATIC WinCC flexible 2008 SP3 Standard
- SIMATIC WinCC flexible 2008 SP3 Advanced
Benefits
The integrated configuration software reduces training,
maintenance and service overhead and protects the
customer's investments
Minimized configuration overhead due to reuse of scalable
and dynamizable objects
Tools for efficient and simple configuration:
- Wizard for defining the basic structure of the HMI project
- Table-based editors simplify the generation and processing
of similar types of object, e.g. for tags, texts, or alarms.
- Complex configuration tasks such as the definition of paths
of motion or the creation of the fundamental operator
prompting are simplified by means of graphical configu-
ration.
Comprehensive support of multi-language configurations for
worldwide use
- Selectable views for entering configuration data in several
languages
- System and user-specific text lexicons
- Export/import of language-dependent texts
Application
SIMATIC WinCC flexible Micro/Compact/Standard/Advanced
are engineering tools for configuring SIMATIC HMI devices, the
operating component of SIMATIC C7 devices, the SIMOTION/
SINUMERIK Panel PCs as well as the PC-based visualization
system WinCC flexible Runtime.
Depending on the selected product, various target systems can
be configured:
WinCC flexible Micro
Micro Panels: OP 73micro, TP 170micro, TP 177micro
WinCC flexible Compact
In addition to the target systems that are configured using
WinCC flexible Micro:
Basic Panels: KTP400 Basic, KTP600 Basic, KTP1000 Basic,
TP1500 Basic
Mobile Panels: Mobile Panel 170, Mobile Panel 177
70 series Panels: OP 73, OP 77A, OP 77B
170 series Panels: TP 170A, TP 177A, TP 170B, TP 177B,
OP 170B, OP 177B
170 series Multi Panels: MP 177
C7 devices: C7-635 (Touch/Key)
WinCC flexible Standard
In addition to the target systems that are configured using
WinCC flexible Compact:
Mobile Panels: Mobile Panel 277
270 series Panels: TP 270, TP 277, OP 270, OP 277
270 series Multi Panels: MP 270B, MP 277
370 series Multi Panels: MP 370, MP 377
C7 devices: C7-636 (Touch/Key)
WinCC flexible Advanced
In addition to the target systems that are configured using
WinCC flexible Standard:
Standard PC
SIMATIC Panel PC: Panel PC IL 70, Panel PC IL 77,
Panel PC 477/477B, Panel PC 577/577B, Panel PC 670,
Panel PC 677/677B, Panel PC 870, Panel PC 877
SIMOTION Panel PC: P012K, P012T, P015K, P015T, PCR,
PCR-Touch
SINUMERIK Panel PC: HT8, OP08T, OP010, OP012, TP012,
OP015, TP015, OP015A
For configuring panels released after the start of delivery of
WinCC flexible 2008, an HSP (Hardware Support Package)
is required that can be downloaded free of charge via the
following link:
http://www.siemens.com/wincc-flexible-hsp
ST80_2013_EN_Kap04.book Seite 60 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible ES
4/61
Siemens ST 80 / ST PC · 2013
Design
The engineering tools of the SIMATIC WinCC flexible range are
based on one another. The available editors largely depend on
the respectively configured target systems and their functions.
A more comprehensive engineering tool such as WinCC flexible
Standard also offers the facilities of the smaller engineering
tools, e.g. WinCC flexible Compact or Micro.
Upgrading of a smaller engineering tool to a larger one is
possible using a Powerpack. An exception is WinCC flexible
Micro.
The scope of functions of the WinCC flexible engineering tools
already includes project support for the Runtime options
available for SIMATIC Panels or WinCC flexible Runtime,
independent of the RT licenses purchased. Separate licensing
is required for the target system in order to use the configured
Runtime options.
Function
Integration into automation systems
Integration into SIMATIC STEP 7 V5.x and Simotion
- Management of HMI projects within the SIMATIC Manager
- Shared use of communication settings and process point
definitions, i.e., symbols and messages
- Display of the HMI configuring objects in the
SIMATIC Manager
- Transfer of configuring data via MPI/PROFIBUS/Ethernet
using routing
Configuration interface
Comprehensive and fast access to editors and project data
via Workbench applications
Adaptive user interface of engineering tools depending on
configured target system
User-definable user interface settings, e.g., layout, toolbars,
object defaults
Project handling
Device-independent configuration data can be used on a
variety of target systems without the need for conversion;
the interface adapts to the functional possibilities of the device
currently configured.
Cross-device utilization of common configuration data
(e.g., text library) in multi-device projects
Wizard-assisted definition of basic structure of HMI projects
(e.g., display layout, operator prompting)
Screen editor with extensive options for efficient and fast screen
configuration
Generation of interconnected screen objects via Drag&Drop,
e.g., tags for the creation of input/output fields with process
interfacing or buttons with screen selection function
Template for the definition of global screen objects and
functions (comparable with the Slide Master in
MS PowerPoint)
User-friendly editor for the creation of image blocks with
defined external interface from screen objects
Graphics-based configuration of motion paths
Layer technology with up to 32 layers
Tools for the Align, Rotate and Mirror functions
Import/export
of texts for translation
of tags, links, text lists, and messages
Generation of variable lists for importing from controller
programming tools
Object-based data management with user-friendly search and
edit options
Cross-reference list with direct access to all objects,
e.g. for editing or selection
Search for objects in entire project
Central reassignment of variables
Text search and replace functions
Libraries for predefined/user-defined configuration objects
Large number of scalable and dynamizable screen objects
included in scope of delivery
Size-scalable WMF-format graphics for industrial applications
included in scope of delivery
Preview function for library objects
Storage of all engineering objects in library, e.g., blocks and
even entire displays or variables;
picture blocks can be created on a customer- or project-
specific basis by combining simple screen objects.
Changes to these picture blocks can be made centrally
(block definition).
Language support
Multilingual project creation (max. 32 languages) in editors
thanks to selectable views
Automatic translation on basis of system- and user-specific
dictionaries in central text library
Central management of language-specific texts and graphics
in libraries
Edit, export and import of texts for translation
Language-specific graphics
Visual Basic Script support
IntelliSense function for fast programming of access to
runtime objects
Simple creation of control sequences in script code;
Script debugging in Simulator and WinCC flexible Runtime
Test and startup support
Simulation of HMI projects on engineering PC
Jump to error cause based on alarm messages in the
Compiler
Advanced ProSave service tool for all operating systems
supported by WinCC flexible
ChangeControl (option)
Version management of project versions with rollback
Logging of configuration changes,
e.g., for regulated industries
Note:
For further information, refer to "WinCC flexible options".
Default runtime data in engineering tools
Users and passwords
Recipe data records
ST80_2013_EN_Kap04.book Seite 61 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible ES
4/62 Siemens ST 80 / ST PC · 2013
4
Technical specifications
1)
In addition to the space needed by WinCC flexible, Windows also requires
space on the hard disk;
e.g. for the swap file. The following formula has proven itself in the past:
The size of the swap file = 3 x the size of available RAM.
For further information, refer to your Windows documentation
2)
When installing one language. An additional 200 MB are required for each
further language. In the case of different partitions for system and configu-
ration: System partition approx. 700 MB, project partition approx. 1.3 GB.
3)
When installing one language. An additional 80 MB are required for each
further language. In the case of different partitions for system and configu-
ration: System partition approx. 600 MB, project partition approx. 600 MB.
Ordering data
Order No. Order No.
System requirements
(minimum requirements) WinCC flexible
Engineering Software
Operating system Windows XP Professional SP3
(32 bit),
Windows 7 Professional, Ultimate,
Enterprise (32 and 64 bit)
Additionally for
SIMATIC WinCC flexible Micro:
Windows XP Home SP3
Processor Pentium 4 (or comparable) proces-
sor running at 1.6 GHz or faster
Resolution 1024 x 768 or higher
Main memory (RAM) 1 GB,
512 MB for WinCC flexible Micro
Hard disk (free memory space)
1)
2 GB
2)
1.2 GB for WinCC flexible Micro
3)
DVD drive for software installation
WinCC flexible 2008 Micro
incl. SP3 6AV6610-0AA01-3CA8
Single license, without license key
software and documentation on
DVD, without license key, contains:
Engineering software for configu-
ration of Micro Panels
Electronic documentation (.pdf)
WinCC flexible 2008 Compact
incl. SP3 6AV6611-0AA51-3CA5
Floating license, license key on USB
stick, software and documentation
on DVD, contains:
Engineering software for configur-
ing Micro Panels, Basic Panels
and 70/170 series Panels incl.
C7-635
Software for
WinCC flexible /ChangeControl
engineering option
1)
• Simulation software for
Micro Panels, Basic Panels, and
70/170 series Panels incl. C7-635
• Native drivers
Electronic documentation (.pdf)
WinCC flexible 2008 Standard
incl. SP3 6AV6612-0AA51-3CA5
Floating license, license key on USB
stick, software and documentation
on DVD, contains:
Engineering software for configur-
ing Micro Panels, Basic Panels
and 70/170/270/370 series Panels
incl. C7-635/636
Software for
WinCC flexible /ChangeControl
engineering option
1)
• Simulation software for
Micro Panels, Basic Panels,
and 70/170/270/370 series Panels
incl. C7-635/636
• Native drivers
Electronic documentation (.pdf)
1)
A separate license for WinCC flexible /ChangeControl must be purchased
for each engineering station
2)
The ChangeControl option has not been released for integrated operation
with STEP 7
WinCC flexible 2008 Advanced
incl. SP3 6AV6613-0AA51-3CA5
Floating license, license key on USB
stick, software and documentation
on DVD, contains:
• Engineering software for configur-
ing WinCC flexible Runtime on
basic PCs/Panel PCs as well as
Micro Panels, Basic Panels and
70/170/270/370 series Panels incl.
C7-635/636
• Software for
WinCC flexible /ChangeControl
engineering option
1)
• Simulation software for
WinCC flexible Runtime as well
as Micro Panels, Basic Panels,
and 70/170/270/370 series Panels
incl. C7-635/636
• Native drivers
• Electronic documentation (.pdf)
WinCC flexible /ChangeControl
for WinCC flexible 2008
Compact/Standard/Advanced
1) 2)
6AV6613-6AA01-3AB5
Floating license, option, license key
only
Powerpacks
SIMATIC WinCC flexible
Powerpacks
Single license, license key only
• WinCC flexible 2008 Standard
to 2008 Advanced 6AV6613-2CD01-3AD5
• WinCC flexible 2008 Compact
to 2008 Advanced 6AV6613-2BD01-3AD5
• WinCC flexible 2008 Compact
to 2008 Standard 6AV6612-2BC01-3AD5
Updates
WinCC flexible 2008
Micro Update 2008, 2008 SP1,
2008 SP2 -> 2008 SP3
6AV6610-0AA51-3CU8
WinCC flexible 2008
Compact/Standard/Advanced
Update 2008, 2008 SP1,
2008 SP2 -> 2008 SP3
6AV6613-0AA51-3CU8
ST80_2013_EN_Kap04.book Seite 62 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible ES
4/63
Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
1)
A separate license for WinCC flexible /ChangeControl must be purchased
for each engineering station
2)
Original delivery note or Certificate of License (CoL) from previous
WinCC flexible Micro is required
More information
Additional information is available in the Internet under:
http://www.siemens.com/wincc-flexible Note
Do you require a specific modification or extension to the
products described here? You will find information about the
Open Platform Program for the creation of user-specific
functions and controls for WinCC flexible under "Customized
Products".
Upgrades
SIMATIC WinCC flexible
2004/2005/2007
to SIMATIC WinCC flexible
2008 incl. SP3
Upgrade to
WinCC flexible 2008 Micro
2)
6AV6610-0AA01-3CE8
Upgrade to
WinCC flexible 2008 Compact,
incl. ChangeControl option
1)
6AV6611-0AA51-3CE5
Upgrade to
WinCC flexible 2008 Standard,
incl. ChangeControl option
1)
6AV6612-0AA51-3CE5
Upgrade to
WinCC flexible 2008 Advanced,
incl. ChangeControl option
1)
6AV6613-0AA51-3CE5
SIMATIC WinCC flexible ASIA
2004/2005/2007
to SIMATIC WinCC flexible ASIA
2008 incl. SP3
Upgrade to
WinCC flexible 2008
ASIA Standard,
incl. ChangeControl option
1)
6AV6612-0AA11-3CE5
Upgrade to
WinCC flexible 2008
ASIA Advanced,
incl. ChangeControl option
1)
6AV6613-0AA11-3CE5
Versions for
China/Taiwan/Korea/Japan
WinCC flexible 2008 ASIA
Standard incl. SP3 6AV6612-0AA11-3CA5
Floating license, license key on USB
stick, software and documentation
on DVD, contains:
Engineering software for configur-
ing Micro Panels, Basic Panels
and 70/170/270/370 series Panels
incl. C7-635/636
• Simulation software for
Micro Panels, Basic Panels and
70/170/270/370 series Panels incl.
C7-635/636
• Native drivers
Electronic documentation (.pdf)
WinCC flexible 2008 ASIA
Advanced incl. SP3 6AV6613-0AA11-3CA5
Floating license, license key on USB
stick, software and documentation
on DVD, contains:
• Engineering software for configur-
ing WinCC flexible Runtime as well
as Micro Panels, Basic Panels and
70/170/270/370 series Panels incl.
C7-635/636
• Software for
WinCC flexible /ChangeControl
engineering option
1)
• Simulation software for
WinCC flexible Runtime as well
as Micro Panels, Basic Panels,
and 70/170/270/370 series Panels
incl. C7-635/636
• Native drivers
• Electronic documentation (.pdf)
Documentation
(must be ordered separately)
User Manual
WinCC flexible Communication
•German 6AV6691-1CA01-3AA0
• English 6AV6691-1CA01-3AB0
• French 6AV6691-1CA01-3AC0
•Italian 6AV6691-1CA01-3AD0
•Spanish 6AV6691-1CA01-3AE0
WinCC flexible Micro
User Manual
•German 6AV6691-1AA01-3AA0
• English 6AV6691-1AA01-3AB0
• French 6AV6691-1AA01-3AC0
•Italian 6AV6691-1AA01-3AD0
•Spanish 6AV6691-1AA01-3AE0
User Manual
WinCC flexible
Compact/Standard/Advanced
•German 6AV6691-1AB01-3AA0
• English 6AV6691-1AB01-3AB0
• French 6AV6691-1AB01-3AC0
•Italian 6AV6691-1AB01-3AD0
•Spanish 6AV6691-1AB01-3AE0
ST80_2013_EN_Kap04.book Seite 63 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible RT
4/64 Siemens ST 80 / ST PC · 2013
4
Overview
PC-based visualization software for single-user systems directly
at the machine.
Runs under Windows XP Professional and
Windows 7 Professional, Ultimate, Enterprise
Current version: SIMATIC WinCC flexible 2008 SP3 Runtime
SIMATIC WinCC flexible Runtime is configured with the
SIMATIC WinCC flexible Advanced configuration software.
Benefits
Optimum price/performance ratio thanks to individually
scalable system functionality
Functions for all visualization tasks:
Operator functions, graphical and trend displays, signaling
system, log system, archiving (option), recipe management
(option), Audit Trail (option), process fault diagnostics (option)
Flexible runtime functionality thanks to Visual Basic scripts
Innovative service concepts with remote operation,
diagnostics and administration via intranet and Internet as
well as e-mail communication to increase availability (option)
Support for simple distributed automation solutions based on
TCP/IP networks at the machine level (option)
Application
SIMATIC WinCC flexible Runtime is the high-performance visual-
ization software for simple visualization tasks at machine level.
It can be used as a single-user solution for all automation appli-
cations in factory automation, process automation and building
services automation.
SIMATIC WinCC flexible Runtime can be used in combination
with the following operator panels:
SIMATIC Panel PCs
- PC IL 70/77
- Microbox 420
- Panel PC 477
- Panel PC 577
- Panel PC 670/677
- Panel PC 870/877
SIMOTION Panel PCs
- P012, P015
- PCR, PCR-Touch
SINUMERIK Panel PCs
- HT8; OP08T
- OP010, OP012, OP015
- TP012, TP015, OP015A
Standard PCs with resolutions (W x H in pixels) of:
- 4:3 format: 640 x 480, 800 x 600, 1024 x 768, 1280 x 1024,
1600 x 1200
- Widescreen format: 800 x 480, 1280 x 800, 1366 x 768,
1440 x 900, 1680 x 1050, 1920 x 1080, 1920 x 1200,
1980 x 1080
Design
SIMATIC WinCC flexible Runtime is available as a software
package with 128, 512, 2048 or 4096 PowerTags. The term
PowerTags is used exclusively to identify process variables and
range pointers that have a process link to the controller.
Variables without process link, constant limit values of variables,
and messages (up to 4000 bit-triggered messages) are also
available for additional system performance.
The range of functions of WinCC flexible Runtime includes the
centralized HMI components for visualizing and reporting, and it
can be expanded to suit requirements and costs by using
optional packages.
SIMATIC WinCC flexible Runtime is configured with the
SIMATIC WinCC flexible Advanced configuration software.
ST80_2013_EN_Kap04.book Seite 64 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible RT
4/65
Siemens ST 80 / ST PC · 2013
Function
Visualization via Windows-compliant operator interface
made up of parameterizable screen objects and image blocks
created on a project-specific basis:
Numeric and alphanumeric input/output fields
Static text and graphic display plus vector graphics
Dynamizable graphics from HMI symbol library
Bar graph, trend curve graph with scroll and zoom function as
well as read line
Signal-specific text and graphic lists
Buttons and switches for operator-process communication
Editing fields for process values (signals)
Analog display, slider as example for further screen objects
Project-specific image blocks created from system basic
objects
Graphic displays for various standard graphic formats,
e.g., bitmaps, .jpg, .wmf
Alarms and messages
Discrete alarms and analog alarms as well as event-driven
Alarm-S/Alarm-D message procedure with SIMATIC S7 and
SIMOTION
Freely-definable message classes for definition of acknowl-
edgment response and display of message events
Logging of alarms and process values
1)
Archiving in files (e.g. CSV or TXT file) and Microsoft SQL
databases
Online evaluation of process value archives and alarm logs
Evaluation of process value archives and alarm logs using
standard Microsoft tools such as Excel
Recipes
1)
Generation of data records for machine or production data
Display or entry of data records via a configurable screen
object or via process images when distributed within the
project
Transmission of data records from or to the PLC
Import/export for data records from/to CSV files
Documentation of process data, alarm events and recipes
Time- or event-driven report output
User-definable layout
Flexible expansion of system function
thanks to Visual Basic Script
Language support for multilingual projects
Up to 16 online languages (incl. Asian and Cyrillic)
Language-dependent texts and graphics
Language selection during runtime
User-oriented access protection according to requirements
of regulated sectors
Authentication with user ID and password
User-group-specific rights
Central system-wide user administration based on
SIMATIC Logon
1)
Monitoring of changes by operators in runtime operation
1)
Recording of operator actions in an Audit Trail
1)
PLC link for a wide variety of PLCs on-board
Simultaneous connection using several protocols: OPC Client
or SIMATIC HMI HTTP protocol are additive, i.e. can be used
in conjunction with other PLC links
Communication via native drivers and standard OPC channel
Open communication between
HMI systems and with higher-level systems
1)
•OPC server
Sm@rtAccess for communication between HMI systems
based on Ethernet networks, or via the intranet/Internet:
Read and write access to variables;
WinCC flexible Runtime or SIMATIC Panels make data
(variables) available to other SIMATIC HMI systems or Office
applications.
A SIMATIC HMI system can be used to control or monitor
another system remotely;
entry level for client/server configurations for distributed
operator stations or for solutions with headend or control
room.
Sm@rtService for remote control,
diagnostics and administration via intranet and Internet
1)
Display and control of process images on remote PC or Panel
Sending of e-mails on demand or event-driven
System diagnostics visualized via device-specific HTML
pages
1)
Option for SIMATIC WinCC flexible Runtime; runtime licenses
must be purchased separately. For further information, refer to
"WinCC flexible options".
1)
Only for enabled platforms (e.g. Panel PC 477).
You can get information from your Siemens contact.
2)
RAM requirements are determined primarily by the size of the graphics
used.
3)
Without taking archives into account.
In addition to the space needed by WinCC flexible, Windows also requires
space on the hard disk; e.g., for the swap file. The following formula has
proven itself in the past: The size of the swap file = 3 x the size of the RAM.
For further information, refer to your Windows documentation
4)
More powerful systems (Pentium 4 and higher) may be required in order to
use options
System requirements WinCC flexible Runtime
Operating system Windows XP Professional SP3
(32 bit)
Windows XP Embedded
1)
Windows 7 Professional / Ultimate /
Enterprise (32 bit and 64 bit)
Processor
4)
• Minimum Windows XP: 300 MHz
Windows 7: 1 GHz
• Recommended Windows XP: Pentium III, 500 MHz
Windows 7: 1 GHz
Graphics
• Minimum SVGA
• Resolution 640 x 480 to 1600 x 1200 or
800 x 480 to 1980 x 1080
RAM
2)
• Minimum Windows XP: 128 MB
Windows 7: 1 GB
• Recommended Windows XP: 512 MB
Windows 7: 1 GB
Hard disk (free memory space)
3)
250 MB
ST80_2013_EN_Kap04.book Seite 65 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible RT
4/66 Siemens ST 80 / ST PC · 2013
4
Integration
SIMATIC WinCC flexible Runtime supports linking to:
1)
WinCC flexible Runtime is passive (DP slave); the function block required
for the link is included in the scope of delivery of WinCC flexible
2)
For Microbox 427 and Panel PC 477/577/677 via internal MPI/DP interface
3)
Only point-to-point to S7-200; no configuration download, operating
systems: Windows 2000/XP; Order number: 6ES7 901-3CB30-0AX0
4)
Constraint with regard to baud rate for S7-200; see Catalog ST 70
5)
WinCC flexible RT is active; communication with S7 functions
6)
Only point-to-point to S7-300/-400; No configuration download, operating
systems: Windows 2000/XP; order number: 6ES7 972-0CB20-0XA0 (USB)
7)
For Microbox 427 and Panel PC 477/577/677/877 via internal Ethernet
interface
8)
For further information, see Catalog PM 10
9)
"SINUMERIK HMI copy license OA" option required; for further information,
see Catalog NC 60
10)
OPC Client is included in scope of delivery,
the "WinCC flexible /OPC Server for WinCC flexible Runtime" license is
required for the OPC Server option
11)
"WinCC flexible /Sm@rtAccess for WinCC flexible Runtime" license
required
12)
OPC and HTTP communication are additive, i.e. can be used in
conjunction with the PLC links listed above
13)
Via PC cable with integrated level converter RS 232/TTY;
Order number: 6ES5 734-1BD20
For information about SIMATIC Panels that support OPC/http
communication, see the overview under "System interfaces".
Protocol PC interfaces
SIMATIC S5 via AS511 (TTY)
S5-90U COM1/COM2
13)
S5-90U
S5-100U (CPU 100, 102, 103)
S5-115U
(CPU 941, 942, 943, 944, 945)
S5-135U (CPU 928A, 928B)
S5-155U (CPU 946/947, 948)
SIMATIC S5 via PROFIBUS DP
1)
S5-95U/L2-DP master CP 5512
2)
CP 5611 A2
2)
S5-115U
(CPU 941, 942, 943, 944, 945)
S5-135U (CPU 928A, 928B)
S5-155U (CPU 946/947, 948)
SIMATIC S7 via PPI
S7-200 CP 5512
2)
CP 5611 A2
2)
CP 5621
1)
CP 5613 A2
CP 5614 A2
PC/PPI adapter
3)
SIMATIC S7 via MPI
S7-200 (except CPU 212)
4)
CP 5512
2)
CP 5611 A2
2)
CP 5621
1)
CP 5711
2)
CP 5613 A2
CP 5614 A2
PC adapter USB
6)
Teleservice V6.1
S7-300
S7-400
WinAC Basis (V3.0 and higher)
WinAC RTX
SIMATIC S7 via PROFIBUS DP
5)
S7-215
4)
CP 5512
2)
CP 5611 A2
2)
CP 5621
1)
CP 5711
2)
CP 5613 A2
CP 5614 A2
S7-300 CPUs
with integr. PROFIBUS interface
S7-300 with CP 342-5
S7-400 CPUs
with integr. PROFIBUS interface
S7-400 with CP 443-5 or IM 467
WinAC Basis (V3.0 and higher)
WinAC RTX
SIMATIC S7 via Ethernet (TCP/IP)
S7-200 with CP 243-1 CP 1612
7)
CP 1613 A2
S7-300 CPUs
with integral Ethernet interface
S7-300 with CP 343-1
S7-400 CPUs
with integral Ethernet interface
S7-400 with CP 443-1
WinAC Basis (V3.0 and higher)
WinAC RTX
SIMATIC S7 via integrated interface
WinAC Basis (V2.0 and higher) Internal system interface
WinAC RTX
SIMATIC 505 NITP
SIMATIC 500/505 RS 232/RS 422 COM1/COM2
SIMATIC 505 via PROFIBUS DP
SIMATIC 545/555 with CP 5434 CP 5512
2)
CP 5611 A2
2)
SIMOTION
8)
SINUMERIK
9)
Third-party controllers
Allen Bradley (DF1/DH485) COM1/COM2
Allen Bradley (Ethernet) CP 1612
7)
GE Fanuc (SNP/SNPX) COM1/COM2
LG GLOFA GM COM1/COM2
Mitsubishi (FX/MP4) COM1/COM2
Modicon (Modbus) COM1/COM2
Modicon (Modbus TCP/IP) CP 1612
7)
OMRON (Link/Multilink) COM1/COM2
OPC
10) 12)
Data Access V2.05a (client + server) CP 1612
7)
Data Access XML V1.00 (client)
HTTP communication for data
exchange between SIMATIC HMI
(client + server)
11) 12)
CP 1612
7)
Protocol PC interfaces
ST80_2013_EN_Kap04.book Seite 66 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible RT
4/67
Siemens ST 80 / ST PC · 2013
Integration (continued)
Application note
In parallel with each and every PLC link, WinCC flexible Runtime
supports the use of the OPC Client channel; this enables, for
example, connection to an SNMP OPC Server for the purpose of
visualizing the data stored there.
The SNMP OPC Server provides a means of monitoring network
components of any type (e.g. switches) which support the SNMP
protocol. For further information, see Catalog IK PI.
Note:
For further information, see "HMI devices/System interfaces"
SIMATIC WinCC flexible Runtime application example
Higher level visualization system
On-site visualization
OPC Client
Non-Siemens
PLCs
OPC Client
OPC Server
OPC Server
3rd party
OPC Server
G_ST80_XX_00077
SIMATIC S7-300 SIMATIC S7-400
Industrial Ethernet
PROFIBUS
ST80_2013_EN_Kap04.book Seite 67 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible RT
4/68 Siemens ST 80 / ST PC · 2013
4
Technical specifications
1)
Together only 500 text and graphics lists
2)
Dependent on memory medium used
3)
Dependent on number of licensed PowerTags
4)
Option for SIMATIC WinCC flexible Runtime.
For further information, refer to "WinCC flexible options".
Type SIMATIC WinCC flexible Runtime
The specifications are
maximum values
Displays 500
Fields per screen 400
Variables per screen 400
• Static text 30,000
Graphics objects 2,000
• Complex objects per display
(e.g. bars) 40
•Trends 800
Graphics lists
1)
500
•Text lists
1)
500
• Number of entries in symbol tables 3,500
Variables 4,096
3)
Messages bit-triggered / analog 4,000 / 500
Message text (number of characters) 80
• Number of process values per mes-
sage 8
Size of message buffer 1,024
Pending message events 500
Archives
4)
100
Archivable data Process data,
messages
Max. number of entries per archive
(incl. all archive segments) 500,000
Archive types Short-term archive, sequence
archive (max. 400 per archive)
Data storage format CSV (Comma Separated Variable),
RDB (Runtime Data Base),
interface to MS SQL database
Recipes
4)
1,000
Elements per recipe 2,000
3)
Data records per recipe 5,000
2)
Password protection
• User rights 32
• Number of user groups 50
Visual Basic scripts 200
Online languages, max. 16
Communication
SIMATIC S7 MPI interface/
PROFIBUS DP interface
• Number of connectable stations,
max. Depending on the scope of the
configuration (communication) from
the point of view of WinCC flexible
Runtime, as many as 8 connections
are possible
SIMATIC S7 PPI interface
• Number of connectable stations,
max. 1 from viewpoint of
WinCC flexible Runtime
SIMATIC S5
PROFIBUS DP interface
• Number of connectable stations,
max. 1 from viewpoint of
WinCC flexible Runtime
Multi-protocol operation Yes, OPC Client or SIMATIC HMI
HTTP protocol are additive, i.e. can
be used in conjunction with other
PLC links
Type SIMATIC WinCC flexible Runtime
ST80_2013_EN_Kap04.book Seite 68 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible RT
4/69
Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
1)
Runtime licenses for WinCC flexible Runtime options must be purchased
separately for each target system.
SIMATIC WinCC flexible 2008
Runtime
for PC systems;
incl. SW for PC systems options
1)
Single license,
on CD-ROM incl. licensing, for:
• 128 PowerTags (RT 128) 6AV6613-1BA51-3CA0
• 512 PowerTags (RT 512) 6AV6613-1DA51-3CA0
2048 PowerTags (RT 2048) 6AV6613-1FA51-3CA0
4096 PowerTags (RT 4096) 6AV6613-1GA51-3CA0
Powerpacks
SIMATIC WinCC flexible 2008
Runtime
Single license, only license key
for PowerTags, from
128 to 512 PowerTags 6AV6613-4BD01-3AD0
• 128 to 2048 PowerTags 6AV6613-4BF01-3AD0
• 512 to 2048 PowerTags 6AV6613-4DF01-3AD0
• 128 to 4096 PowerTags 6AV6613-4BG01-3AD0
• 512 to 4096 PowerTags 6AV6613-4DG01-3AD0
2048 to 4096 PowerTags 6AV6613-4FG01-3AD0
Updates
SIMATIC WinCC flexible 2008
Runtime
Update 2008, 2008 SP1, 2008 SP2
-> 2008 SP3
6AV6613-1XA51-3CU8
Upgrades
SIMATIC WinCC flexible
2004/2005/2007 Runtime
to SIMATIC WinCC flexible 2008
Runtime
Upgrade to
SIMATIC WinCC flexible Runtime
2008 PowerTags
incl. Runtime Options for:
6AV6613-1XA51-3CE0
- WinCC flexible /Archives
- WinCC flexible /Recipes
- WinCC flexible /Audit
- WinCC flexible /Sm@rtAccess
- WinCC flexible /Sm@rtService
- WinCC flexible /OPC server
- WinCC flexible /ProAgent
Upgrade of the SIMATIC
WinCC flexible Panel options: 6AV6618-7XX01-3AF0
- WinCC flexible /Audit
for SIMATIC Panel
- WinCC flexible /Sm@rtAccess
for SIMATIC Panel
- WinCC flexible /Sm@rtService
for SIMATIC Panel
- WinCC flexible /OPC server
for SIMATIC Multi Panel
- WinCC flexible /ProAgent
for SIMATIC Multi Panel
Documentation
(must be ordered separately)
User Manual
WinCC flexible Runtime
•German 6AV6691-1BA01-3AA0
• English 6AV6691-1BA01-3AB0
• French 6AV6691-1BA01-3AC0
•Italian 6AV6691-1BA01-3AD0
•Spanish 6AV6691-1BA01-3AE0
User Manual
WinCC flexible Communication
•German 6AV6691-1CA01-3AA0
• English 6AV6691-1CA01-3AB0
• French 6AV6691-1CA01-3AC0
•Italian 6AV6691-1CA01-3AD0
•Spanish 6AV6691-1CA01-3AE0
SIMATIC HMI Manual Collection 6AV6691-1SA01-0AX0
Electronic documentation, on DVD
5 languages (English, French,
German, Italian and Spanish);
contains: all currently available
user manuals, device manuals
and communication manuals for
SIMATIC HMI
ST80_2013_EN_Kap04.book Seite 69 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible HMI system
SIMATIC WinCC flexible RT
4/70 Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
4
More information
Additional information is available in the Internet under:
http://www.siemens.com/wincc-flexible
Note
Do you need a specific modification or option for the products
described here? You will find information about the Open
Platform Program for the creation of user-specific functions and
controls for WinCC flexible under "Customized Products".
Communication
via Industrial Ethernet
CP 1613-A2 6GK1161-3AA01
PCI card (32-bit) for connecting
a PG/PC to Industrial Ethernet
(communications software must
be ordered separately)
SIMATIC NET IE S7-1613 V8.0 SP1
Software for S7 and open communi-
cation, incl. PG/OP communication,
OPC server and NCM PC; up to
120 connections, Runtime software,
software and electronic manual on
CD-ROM, license key on USB flash
drive, Class A, for 32-bit Windows 7
Professional/Ultimate for up to
4 CP 1613/CP 1613 A2 / CP 1623;
English/German
Single license for 1 installation 6GK1716-1CB80-3AA0
Software Update Service for one
year, with automatic extension;
requirement: Current software
version
6GK1716-1CB00-3AL0
• Upgrade S7-1613 from V6.4 to
S7-1613 V8.0 SP1 6GK1716-1CB00-3AE0
Upgrade S7-1613 from V6.0, V6.1,
V6.2 or V6.3 to S7-1613 V8.0 SP1 6GK1716-1CB00-3AE1
Communication via PROFIBUS
CP 5613-A2 6GK1561-3AA01
PCI card (32-bit) for connecting a
PC to PROFIBUS (communications
software must be ordered sepa-
rately)
CP 5614-A2 6GK1561-4AA01
PCI card (32-bit) for connecting a
PC to PROFIBUS (communications
software must be ordered sepa-
rately)
SIMATIC NET PB S7-5613 V8.0
SP1
Software for S7 communication, incl.
PG and FDL protocol, OPC server
and NCM PC; Runtime software,
software and electronic manual on
USB flash drive, license key on dis-
kette, Class A, for 32-bit Windows 7
Professional/Ultimate for up to
4 CP 5613 A2, CP5614 A2,
CP 5603 / CP 5623 / CP 5624;
• Single license for 1 installation 6GK1713-5CB80-3AA0
• Software Update Service for one
year, with automatic extension;
requirement: Current software
version
6GK1713-5CB00-3AL0
Upgrade S7-5613 from V6.4 to
S7-5613 V8.0 SP1 6GK1713-5CB00-3AE0
Upgrade S7-5613 from V6.0, V6.1,
V6.2 or V6.3 to S7-5613 V8.0 SP1 6GK1713-5CB00-3AE1
CP 5512 6GK1551-2AA00
PCMCIA card (32-bit CARDBUS)
for connecting a PG/Notebook to
PROFIBUS or MPI
(communications software
included in WinCC flexible).
CP 5611-A2 6GK1561-1AA01
PCI card (32-bit) for connecting
a PG/PC to PROFIBUS
(communications software included
in WinCC flexible basic package)
CP 5611 MPI 6GK1561-1AM01
Comprising CP 5611 A2 (32-bit)
and MPI cable, 5 m
CP 5621 6GK1562-1AA00
PCI Express X1 card (32-bit) for
connection of PG/PC to PROFIBUS
or MPI (communications software
included in WinCC flexible basic
package)
CP 5711 6GK1571-1AM00
USB adapter (USB V2.0) for
connecting a PG or Notebook to
PROFIBUS or MPI (2 m USB cable
and 5 m MPI cable included)
PC/PPI adapter 6ES7901-3CB30-0XA0
RS 232, 9-pin; male with RS 232/PPI
converter, max. 19.2 kbps
PC adapter USB 6ES7972-0CB20-0XA0
For use with Windows 2000/XP
ST80_2013_EN_Kap04.book Seite 70 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible options
SIMATIC WinCC flexible options
4/71
Siemens ST 80 / ST PC · 2013
Overview
Option for SIMATIC WinCC flexible Engineering
SIMATIC WinCC flexible /ChangeControl
WinCC flexible/ChangeControl enables consistent backup of
configuration data. The history of changes can be verified down
to the last detail for applications requiring interruption-free proof
for the complete life cycle of a product.
Delivered customer projects, approved reference states or
development stages are managed in a database.
Changes to project data can be integrated without problem
into the version management using new versions.
A rollback is possible at any time.
SIMATIC WinCC flexible /Archives
Archiving of alarms and process values
Archiving in files (e.g. CSV file) and Microsoft SQL databases
Online evaluation of process value archives and alarm logs
Evaluation of process value archives and alarm logs using
standard MS tools such as Excel
SIMATIC WinCC flexible /Recipes
Generation and management of data records for machine or
production data
Display or entry of data records via a configurable screen
object or via process images when distributed within the
project
Transmission of data records from or to the controller
Import/export of data sets as CSV files
SIMATIC WinCC flexible /Audit
Recording of operator actions in an Audit Trail
Electronic signature for important operator actions relevant to
production
The ChangeControl option supports users in respect of
tracking modifications to projects.
Audit supports users in meeting special quality requirements,
e.g.
- Production plant requiring validation according to
21 CFR Part 11 (Food Drug Administration law)
- In respect of traceability according to EU 175/2002
(EU directive)
SIMATIC Logon for WinCC flexible
Option for connecting PCs with SIMATIC WinCC flexible Runtime
and SIMATIC Panels to central user administration.
Creates user administration on a central computer to which
one or more WinCC flexible stations can be connected over
Ethernet.
With each logging-on/off of a user on one of the connected
stations, SIMATIC Logon checks whether a user password has
been created and that the required privileges exist.
SIMATIC Logon for WinCC flexible supports the user in combi-
nation with the /Audit and /ChangeControl options in meeting
requirements in accordance with FDA 21 CFR Part 11 and
EU178.
SIMATIC WinCC flexible /Sm@rtAccess
Flexible solution for access to HMI systems and process data
from any location
Communication between different SIMATIC HMI systems
SIMATIC WinCC flexible /Sm@rtService
Remote maintenance and servicing of machines and plant via
Internet/intranet
Reduced downtimes for machines and plant with direct
remote access
Flexible solution for remote access to machines and plant
SIMATIC WinCC flexible /OPC Server
Incorporation of automation components from different
vendors into a single automation concept
Communication for data exchange between HMI systems
and/or higher-level control system
Communication with applications from different vendors,
e.g. MES, ERP or applications in the office sector
SIMATIC WinCC flexible /ProAgent
Precise and rapid process fault diagnostics in plant and
machines for SIMATIC S7 and SIMATIC HMI
Standardized diagnostics concept for various SIMATIC
components
No further configuration overhead for diagnostics functionality
Frees up PLC capacity with regard to memory and program
execution time
ST80_2013_EN_Kap04.book Seite 71 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible options
WinCC flexible /ChangeControl
4/72 Siemens ST 80 / ST PC · 2013
4
Overview
Options for the versioning of configuration data and for tracing
configuration changes (e.g. as verification in regulated
sectors)
For the engineering tool SIMATIC WinCC flexible
Compact/Standard/Advanced
One license is required for each configuration computer
Benefits
Consistent backup of configuration data
- Delivered versions, approved reference states or devel-
opment stages are managed in a database.
- Changes to project data can be integrated without problem
into the version management using new versions. A rollback
is possible at any time.
Tracing of configuration changes
- The history of changes can be verified down to the last detail
for applications requiring interruption-free proof for the
complete life cycle of a product.
Application
In machine/special machine construction for project
management, e.g. delivered customer versions and their
modifications
For saving of intermediate states during complex new devel-
opments or expansions, with rollback facility
During work for specific orders as basis for calculating costs
for modifications
In regulated sectors as proof of state of plants or machines
and any modifications made to them
Function
Integral GUI for management of project versions (version tree
with main line and secondary lines for modified project
versions)
Modification log can be activated/deactivated and shows who
carried out modifications, and when/which. Modification
reasons can be entered as comments
Ordering data
Order No.
1)
The ChangeControl option has not been released for integrated operation
with STEP 7.
More information
Note
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about the Open Platform Program
for the creation of user-specific functions and controls for
WinCC flexible.
WinCC flexible /ChangeControl
for WinCC flexible 2008
Compact/Standard/Advanced
1)
6AV6613-6AA01-3AB5
Floating License, option,
license key only
ST80_2013_EN_Kap04.book Seite 72 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible options
WinCC flexible /Archives
4/73
Siemens ST 80 / ST PC · 2013
Overview
Option for SIMATIC WinCC flexible Runtime for archiving
process values and messages
Archiving of process values and messages supports the
acquisition and processing of process data from an industrial
plant or machine. Evaluation of the archived process data
provides information about the operating states of the plant or
machine
One license is required per operator station
(no license is required for SIMATIC Panels/Multi Panels)
Benefits
Message and process value archives permit foresighted
diagnostics which prevents downtimes
Early detection of danger or fault states
Increase in product quality and productivity thanks to regular
evaluation of process value and message archives
Application
Further use of archives for evaluation and long-term archiving
Record of repeated fault states
Optimization of maintenance cycles
Ensured quality standards
Control of quality as well as production capacity utilization
Documentation of process sequence
Function
Time-controlled as well as manual or process-controlled
swapping out of process data and messages for long-term
archiving
During runtime, swapped out data are read in and selectively
analyzed using WinCC flexible Runtime
- Presentation and evaluation of archived process data based
on a configurable trend display. Reading of the values is
facilitated by a read line.
- Presentation and evaluation of archived alarms based on a
configurable alarm view.
- User-friendly navigation in the archives
External evaluation of the archives using MS standard tools
Various archive types are supported: sequence and short-
term archives
Archiving of process values and messages on external,
Windows-supported storage media
-CSV files
-RDB files
- Microsoft SQL server via ODBC
Power standard functions permit user-friendly and flexible
utilization of the archives
Technical specifications
1)
Dependent on memory medium used
Ordering data
Order No.
1)
One license is required for each operator station. A license is not required
for the engineering system for configuring the runtime option.
More information
Note
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about the Open Platform Program
for the creation of user-specific functions and controls for
WinCC flexible.
Type WinCC flexible /Archives
The specifications are maximum
values
Execution platform SIMATIC WinCC flexible Runtime
Archives 100
• Archivable data Process values, messages
Cyclical trigger for archiving process
values (variables) 1 s
• Max. number of entries per archive
(incl. sequence archive) 500,000
1)
•Archive types Circulating archive
Sequence archive
(max. 400 per archive)
• Data storage format CSV (Comma Separated Variable),
RDB (Runtime Data Base) and
interface to Microsoft SQL data-
base (database not included in
scope of delivery)
WinCC flexible /Archives for
WinCC flexible 2008 Runtime
1)
6AV6618-7ED01-3AB0
Single License, license key only
WinCC flexible /Archives+
Recipes for WinCC flexible 2008
Runtime
1)
6AV6618-7GD01-3AB0
Single License for each option,
license key only
ST80_2013_EN_Kap04.book Seite 73 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible options
WinCC flexible /Recipes
4/74 Siemens ST 80 / ST PC · 2013
4
Overview
Option for SIMATIC WinCC flexible Runtime for managing data
records in recipes that contain related machine or production
data
The data in a data set can be transferred, for example, from
the control unit to the PLC to switch production to a different
product variant
One license is required per operator station (no license is
required for SIMATIC Panels/Multi Panels)
Benefits
Generation and management of machine parameters and
production data on the basis of data sets, and exchange with
the automation equipment, e.g. with the machine
Clear tabular representation of data elements with support of
a configurable graphic object, or representation in technical
relationships for several process graphics
Simple operator prompting using standard functions
Export/import of data sets for further processing with other
tools (e.g. MS Excel)
Application
Assignment of plant/machine parameters in the production
industry
Batch-oriented production, e.g. in the food or plastics industry
Function
Input of data sets (e.g. operating parameters for a machine,
production data for a plastics processing machine) in
WinCC flexible Runtime, their storage, and passing on to the
PLC
Display and input of data sets using a configurable graphics
object, or distributed among several process displays within
the project
Data set elements are coupled to the process using direct
linking of the variables
Transmission of data records from or to the PLC
Powerful interfaces permit synchronized exchange of data
with the PLC
Saving of data sets on local media or on remote data servers
via networks
Import/export of data sets as CSV files
Logging of data sets, e.g. as batch report/shift report
Convenient and flexible management of data sets using
powerful standard functions
WinCC flexible recipes and the associated data sets are conve-
niently created using a separate editor in the WinCC flexible
Advanced engineering tool, and assigned default data.
A configurable table object is used to display the data during
runtime. Furthermore, the individual data set elements can also
be directly output for several process displays on the basis of
standard input/output boxes. The data can therefore be clearly
presented for the operator in technological layers.
Technical specifications
1)
Dependent on number of licensed PowerTags
2)
Dependent on memory medium used
Ordering data
Order No.
1)
One license is required for each operator station.
A license is not required for the engineering system for configuring the
Runtime option.
More information
Note
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about the Open Platform Program
for the creation of user-specific functions and controls for
WinCC flexible.
Type WinCC flexible /Recipes
The specifications are maximum
values
Execution platform SIMATIC WinCC flexible Runtime
Recipes 1000
• Entries per recipe 2000
1)
• Data records per recipe 5000
2)
• User data length in bytes
per data record 8000 KB
2)
WinCC flexible /Recipes for
WinCC flexible 2008 Runtime
1)
6AV6618-7FD01-3AB0
Single License, license key only
WinCC flexible /Archives+Recipes
for WinCC flexible 2008 Runtime
1)
6AV6618-7GD01-3AB0
Single License for each option,
license key only
ST80_2013_EN_Kap04.book Seite 74 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible options
WinCC flexible /Audit
4/75
Siemens ST 80 / ST PC · 2013
Overview
Option for SIMATIC WinCC flexible Runtime as well as
SIMATIC Panels for recording operations in an audit trail, and
electronic signature
The audit trail features a safety mechanism that indicates
subsequent manipulation.
An easy-to-use configuration option included as standard in
WinCC flexible enables you to set:
- The operator actions to be recorded in the audit trail during
runtime
- The important operator actions requiring electronic
signature/comments during runtime
The audit option combined with the WinCC flexible ES
ChangeControl option supports the user with plant validation
Available for the following SIMATIC HMI systems:
TP/OP 270, TP/OP 277, MP 270B, MP 277, MP 370, MP 377,
WinCC flexible Runtime
A license is required for every operator control unit
(panel or PC)
Benefits
Audit supports the user in meeting special quality require-
ments, e.g.,
- production plant requiring validation according to 21 CFR
Part 11 FDA
2)
- in respect of traceability according to EU 175/2002
3)
Entries in the audit trail are allocated to individual users.
This ensures that responsibilities can be clearly identified.
The audit trail, stored as a CSV file
1)
, can be checked via a
security mechanism to find out if subsequent changes have
been made.
For particularly important user actions, e.g., starting
production or loading new recipes, electronic signatures and
comments can be configured and then called up and logged
during runtime.
1)
CSV Comma Separated Values
2)
The FDA (Food and Drug Administration) is the American public health
authority
3)
21 CFR Part 11- law on plant validation
Technical specifications
Ordering data
Order No.
More information
Note
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about the Open Platform Program
for the creation of user-specific functions and controls for
WinCC flexible.
WinCC flexible /Audit
Archive for Audit Trail use
on the Panel Plug-in flash memory card on the
panel
In the higher-level PC (memory
medium) connected to the panel
via Ethernet
Archive for Audit Trail use of
WinCC flexible Runtime On the PC (storage medium)
Execution platform
SIMATIC Panels Mobile Panel 277, TP/OP 270,
TP/OP 277
SIMATIC Multi Panels MP 270B, MP 277, MP 370, MP 377
PCs SIMATIC WinCC flexible Runtime
WinCC flexible /Audit for
SIMATIC Panels 6AV6618-7HB01-3AB0
Single license, license key only
WinCC flexible /Audit for
WinCC flexible Runtime 2008 6AV6618-7HD01-3AB0
Single license, license key only
ST80_2013_EN_Kap04.book Seite 75 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible options
SIMATIC Logon for WinCC flexible
4/76 Siemens ST 80 / ST PC · 2013
4
Overview
Option for connecting PCs with SIMATIC WinCC flexible
Runtime and SIMATIC Panels to central user administration.
Creates user administration on a central computer to which
one or more WinCC flexible stations can be connected over
Ethernet.
With each logging-on/off of a user on one of the connected
stations, SIMATIC Logon checks whether a user password has
been created and that the required privileges exist.
SIMATIC Logon for WinCC flexible supports the user in combi-
nation with the /Audit and /ChangeControl options in meeting
requirements in accordance with FDA 21 CFR Part 11 and
EU178.
Licensing:
SIMATIC Logon (basic license) and SIMATIC Logon Remote
Access (3-pack license) for connection of 3 WinCC flexible
stations to a central user administration. Additional stations
can be connected by using further SIMATIC Logon Remote
Access licenses (3-pack/10-pack).
Benefits
Centralized configuration of all access authorizations of a
distributed system avoids unnecessary travel times. Time-
consuming multiple configurations for each individual local
station become unnecessary. Accordingly, users can be
easily configured from a central location.
All access data apply throughout the plant on every
connected station. Additional access data on local
subsystems is no longer necessary.
Design
SIMATIC Logon and SIMATIC Logon Remote Access are
installed on a central station.
The following WinCC flexible stations are connected to the
central station via Ethernet network:
PCs with WinCC flexible Runtime
SIMATIC Panels from the 177 series or higher
(panels with Ethernet interface)
Licensing
The following licenses are required:
SIMATIC Logon basic license
SIMATIC Logon Remote Access license (3-pack license
10-pack license); more than one SIMATIC Logon Remote
Access license can be installed.
The number of connectable stations depends on the
SIMATIC Logon Remote Access licenses used. This number is
the total of the connections provided by the individual licenses.
As an example: Two installed licenses for 10 enable the
connection of 20 stations to the central station.
Function
Configuration
In the first step, the following data must be saved in the user
administration of WinCC flexible on every WinCC flexible station
in the plant:
Required user groups with associated user privileges
IP address, port number, Windows domain of the central
station on which the central user administration is stored.
All user groups are configured with the same names in the
central user administration. All users are created here, and have
automatic access to the connected WinCC flexible stations in
accordance with the relevant user group.
If the connection fails between the central station with
SIMATIC Logon and a WinCC flexible station, the operation is
handled through an "emergency user" which must first be
preconfigured locally.
Intervals for password aging and regulations for the structure of
a password are defined according to the configuration on the
central station and then also apply to all decentrally connected
WinCC flexible stations or the respective users.
Technical specifications
SIMATIC Logon for
WinCC flexible
Execution platform
SIMATIC Panels Mobile Panel 177 PN;
Mobile Panel 277,
TP/OP 177B PN/DP, TP/OP 277
SIMATIC Multi Panels MP 177, MP 277, MP 377
PCs WinCC flexible Runtime
ST80_2013_EN_Kap04.book Seite 76 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible options
SIMATIC Logon for WinCC flexible
4/77
Siemens ST 80 / ST PC · 2013
Ordering data
Order No.
More information
Note
Do you need a specific modification or addition to the products
described here? Then take a look under "Customer-specific
products". There, we provide information on the Open Platform
Program for creating your own functions or Controls for
WinCC flexible.
SIMATIC Logon V1.5 6ES7658-7BX51-0YA0
Basic license;
for panels or WinCC flexible
Runtime stations, the corresponding
number of additional
SIMATIC Logon Remote Access
licenses is required.
SIMATIC Logon Upgrade to V1.5 6ES7658-7BX51-0YE0
SIMATIC Logon Remote Access
for WinCC flexible (3 clients) 6ES7658-7BA00-2YB0
Remote access
for 3 WinCC flexible 2008 clients;
single license for 3 remote access
clients;
type of delivery:
CD, license key disk, Certificate
of License, Terms and Conditions
The number of licensed clients is
determined based on the amount
of installed SIMATIC logon remote
access licenses.
SIMATIC Logon Remote Access
for WinCC flexible (10 clients) 6ES7658-7BB00-2YB0
Remote access
for 10 WinCC flexible 2008 clients;
single license for 10 remote access
clients;
type of delivery:
CD, license key disk, Certificate
of License, Terms and Conditions
The number of licensed clients is
determined based on the amount
of installed SIMATIC logon remote
access licenses.
ST80_2013_EN_Kap04.book Seite 77 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible options
WinCC flexible /Sm@rtAccess
4/78 Siemens ST 80 / ST PC · 2013
4
Overview
Option for SIMATIC WinCC flexible Runtime plus
SIMATIC Panels for communication between various
SIMATIC HMI systems.
Available for the following SIMATIC HMI systems:
- Mobile Panel 177 PN, Mobile Panel 277
- TP 177B PN/DP, OP 177B PN/DP
- TP 270, TP 277, OP 270, OP 277
- MP 177, MP 270B, MP 277, MP 370, MP 377
- WinCC flexible Runtime
Communication between HMI systems is established on the
basis of Ethernet networks, or via the intranet/Internet:
- Read and write access to variables;
WinCC flexible Runtime or SIMATIC Panels make data
(variables) available to other SIMATIC HMI systems or Office
applications.
- A SIMATIC HMI system can be used to control or monitor
another system remotely;
entry level for client/server configurations for distributed
operator stations or for solutions with headend or control
room.
Local operation, visualization and data processing is as
possible as plant-wide access to information or central
archiving of process data. Integrated information flows ensure
an overview of the status of all processes.
Licensing:
The license "WinCC flexible /Sm@rtAccess for Panel" or
"WinCC flexible/Sm@rtAccess for WinCC flexible Runtime"
must be installed on both the server and client HMI device.
Server applications are the options Sm@rtServer, HTTP-Server
and SOAP-Server. Client applications are the screen object
Sm@rtClient display, and the utilization of the communication
driver SIMATIC HTTP protocol.
No license is required on the client system for access to a
Sm@rtServer using the application Sm@rtClient.EXE or the
Microsoft Internet Explorer. A license is also not required for
the engineering system for configuring the runtime option.
Note:
If the operator stations are accessed using the Sm@rtAccess
option, suitable protective measures (including IT security such
as network segmentation) should be taken in order to ensure
safe operation of the system.
You will find more information on the topic of Industrial Security
on the Internet at:
http://www.siemens.com/industrialsecurity
Benefits
Flexible solution for location-independent access to
HMI systems and process data
Reduction in load on fieldbuses:
WinCC flexible Runtime as well as SIMATIC Panels permit a
control system, for example, to access the process data. The
sensitive field level is not loaded by the control level as far as
the communications requirements are concerned. The
requirements are processed by WinCC flexible Runtime and
the SIMATIC Panels.
Simple, fast configuration of communications relationships
using the WinCC flexible engineering software
Application
Use of machine-level HMI systems as data servers for higher-
level automation components such as control systems or
office systems. Process values from different machines, for
example, are displayed on a process screen.
Operator control and monitoring of machines covering large
areas with several operator stations by one operator
Operator control and monitoring of machine-level HMI
systems from one central station (e.g. head-end station of a
production line or from a control room)
ST80_2013_EN_Kap04.book Seite 78 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible options
WinCC flexible /Sm@rtAccess
4/79
Siemens ST 80 / ST PC · 2013
Application (continued)
Communication between HMI systems via Industrial Ethernet: Use of machine-level HMI systems as data servers for higher-level automation compo-
nents
Application of the Sm@rtClient concept: Coordinated operation of several operator stations
Server 1 Server 2 Server 3 Server 4
SIMATIC HMI HTTP Protocol
Master Control Station
HTTP Data Client
HTTP-Data
Server/Client
HTTP-Data
Server/Client
HTTP-Data
Server/Client
HTTP-Data
Server/Client
G_ST80_XX_00070
PROFIBUS
Industrial Ethernet
Operator Station 1 Operator Station 2 Operator Station nMaster Station
Sm@rtServer Sm@rtClient
Industrial Ethernet
G_ST80_XX_00071
...
ST80_2013_EN_Kap04.book Seite 79 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible options
WinCC flexible /Sm@rtAccess
4/80 Siemens ST 80 / ST PC · 2013
Application (continued)
4
Use of the Sm@rtClient display: Operator control and monitoring of machine-level HMI systems from one central station
Function
Communication between different SIMATIC HMI systems or
between the units of a machine or plant is carried out via
Industrial Ethernet or intranet/Internet on the basis of
Sm@rtAccess
Possible communication relationships:
Reading and writing the variables of a SIMATIC HMI system on
the basis of an HTTP protocol
- Reading and writing the variables of different HMI systems
- Simple configuring of variables in the HMI client configu-
ration using browsers in the WinCC flexible engineering tool
- Reading and writing the variables of an HMI system using
standard applications such as MS Excel. Communication is
made possible by embedding a script in the application, on
the basis of the SOAP protocol (Simple Object Access
Protocol) superimposed by HTTP
Remote control of an operator station;
the HMI application and communication with the PLC are via
the master station. In the case of spatially distributed
machines/plants (which require a larger number of operator
panels), so-called Sm@rtClients can be activated from here
which are then assigned access to the master station and thus
to the process. Access procedures guarantee that only one
operator system can actively access the process at a time.
- A configurable graphic object (Sm@rtClient display)
embedded in process displays represents the screen of the
associated HMI system (Sm@rtServers)
- Powerful standard functions permit convenient and flexible
operation of the display
Password protection can be optionally activated for access to
variables or for remote operation of an HMI system.
Server 1 Server 2 Server 3 Server 4
Master Control Station Sm@rtClient display
PROFIBUS
Sm@rtServer Sm@rtServer Sm@rtServer Sm@rtServer
Industrial Ethernet
G_ST80_XX_00072
ST80_2013_EN_Kap04.book Seite 80 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible options
WinCC flexible /Sm@rtAccess
4/81
Siemens ST 80 / ST PC · 2013
Technical specifications
1)
Including 1 Service Client
2)
The Sm@rtServer and the WinCC flexible /Pro Agent option cannot be used
simultaneously on OP/TP/MP 270/370. Parallel operation of the runtime
options ProAgent, Sm@rtAccess and Sm@rtService is possible in the
context of the MP 277 8" and 10" devices, Mobile Panel 277 as well as the
MP 377. Limitation: a maximum of 2 clients can be connected simultane-
ously to a Sm@rtServer.
Ordering data
Order No.
1)
The license must be installed on the server and on the client HMI device.
Server applications are the options Sm@rtServer, HTTP-Server and
SOAP-Server.
Client applications are the screen object Sm@rtClient display, and the utili-
zation of the communication driver HTTP protocol.
A license is not required for the engineering system for configuring the
runtime option.
More information
Note
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about the Open Platform Program for the
creation of user-specific functions and controls for
WinCC flexible.
Type WinCC flexible /Sm@rtAccess
The specifications are maximum
values
Execution platform
SIMATIC Panels Mobile Panel 177 PN,
Mobile Panel 277,
TP/OP 177B PN/DP,
TP/OP 270, TP/OP 277
SIMATIC Multi Panels MP 177, MP 270B, MP 277,
MP 370, MP 377
•PCs WinCC flexible Runtime
Sm@rtAccess
SIMATIC HMI HTTP protocol
Number of connections for one client
• Mobile Panel 177 PN,
TP/OP 177 B PN/DP,
MP 177 as HTTP server
4
• Mobile Panel 277, TP/OP 270,
TP/OP 277, MP 270B, MP 277,
MP 370, MP 377 as HTTP server
8
for WinCC flexible Runtime 16
Sm@rtAccess
Sm@rtClient concept
Number of Sm@rtClients that can
connect to a Sm@rtServer at the same
time
1) 2)
• Mobile Panel 177 PN,
TP/OP 177B PN/DP,
MP 177 as Sm@rtServer
2 clients
• Mobile Panel 277, TP/OP 270,
TP/OP 277, MP 270B, MP 277 as
Sm@rtServer
3 clients for 6" devices
2 clients for 8" and 10" devices
MP 370, MP 377 as Sm@rtServer 3 clients for 12" devices
2 clients for 15" devices
1 client for 19" devices
for WinCC flexible Runtime as
Sm@rtServer 5 clients
Number of Sm@rtClient displays per
screen
for Panels/Multi Panels 1
for WinCC flexible Runtime 2
WinCC flexible /Sm@rtAccess
for SIMATIC Panel
1)
6AV6618-7AB01-3AB0
Single license, license key only
WinCC flexible /Sm@rtAccess for
WinCC flexible 2008 Runtime
1)
6AV6618-7AD01-3AB0
Single license, license key only
ST80_2013_EN_Kap04.book Seite 81 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible options
WinCC flexible /Sm@rtService
4/82 Siemens ST 80 / ST PC · 2013
4
Overview
Option for SIMATIC WinCC flexible Runtime and
SIMATIC Panels for remote maintenance and servicing of
machines/plant via the Internet/intranet
Available for the following SIMATIC HMI systems:
- Mobile Panel 177 PN, Mobile Panel 277
- TP 177B PN/DP, OP 177B PN/DP
- TP 270, TP 277, OP 270, OP 277
- MP 177, MP 270B, MP 277, MP 370, MP 377
- WinCC flexible Runtime
Licensing
The "WinCC flexible /Sm@rtService for Panel" license or
"WinCC flexible /Sm@rtService for WinCC flexible Runtime"
license must be installed on the operator panels that use one
of the following options/functions: Sm@rtServer, HTML pages
(mini-Web server), e-mail.
The remote service PC and engineering system do not require
a license for configuration the runtime option.
Note
If the operator stations are accessed using the Sm@rtService
option, suitable protective measures (including IT security such
as network segmentation) should be taken in order to ensure
safe operation of the system.
You will find more information on the topic of Industrial Security
on the Internet at:
http://www.siemens.com/industrialsecurity
Benefits
Fast elimination of faults or downtimes and thus increased
productivity by means of global access to machines/systems
by the service and maintenance personnel
Avoids the need for site visits
Application
Remote maintenance and servicing of machines and plants
via Internet/Intranet
Calling of system information, control of target systems, and
updating of data sets via Internet/Intranet
Automatic sending of emails to experts for fast elimination of
faults
Function
Remote operator control and monitoring of
SIMATIC HMI systems using Industrial Ethernet and/or
via the Intranet/Internet
Microsoft Internet Explorer V6.0 SP1 or higher is sufficient for
accessing an HMI system.
Remote control of an operating station
the HMI application and communication with the controller takes
place via the HMI system. Using Sm@rtService, the HMI systems
in the machines/systems can be serviced remotely. An access
process ensures that only one operator (either locally at the
machine or remotely via Internet Explorer) can actively access
the process at one time.
Integrated Web Server to process standard HTML pages
The following functions can be accessed from the homepage:
Starting and stopping the HMI runtime for maintenance
Remote access to recipe data sets, passwords and infor-
mation specific to the HMI system
Access the HMI system files via a file explorer
Download configuration data via the Intranet/Internet
Supplement with own HTML pages
Sending e-mails to maintenance personnel via SMTP server
(Simple Mail Transfer Protocol)
Events that trigger an e-mail:
- Reporting of a message class
- Configurable standard functions: Changing the value of a
variable, pressing a function key, scripts, etc.
Possible e-mail content
- Subject
- Message text with process variables
- Date/Time
The optional use of e-mail/SMS gateways enables access to
standard networks (external service provider required)
Standard functions make maintenance and service functionality
easier. WinCC flexible allows you to quickly and easily configure
maintenance and service functions.
Password protection can be activated as an option for
accessing the HMI system. Different passwords may be
configured for different functions.
ST80_2013_EN_Kap04.book Seite 82 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible options
WinCC flexible /Sm@rtService
4/83
Siemens ST 80 / ST PC · 2013
Function (continued)
Remote operator control and monitoring of SIMATIC HMI systems using
Industrial Ethernet and/or via the Intranet/Internet
Remote operator control and monitoring of SIMATIC HMI systems using
Industrial Ethernet and/or via the Intranet/Internet
Remote operator control and monitoring of SIMATIC HMI systems using
Industrial Ethernet and/or via the Intranet/Internet
Sending e-mails to maintenance personnel via SMTP server
(Simple Mail Transfer Protocol)
lGz
wjVwn
pG
p
{jwVpw
pzkuVkzs
tVy
pzkuVkzs
tVy
G_ST80_XX_00073
lG
zGwjVwn
pG
p
{jwVpw
pzkuVkzs
tVy
pzkuVkzs
tVy
G_ST80_XX_00074
wyvmpi|z
jGXaG
vGGG
GGtGpG
l
jGYaG
vGGG
GGpVpG
GGGGb
GGG
Engineering Station
PC/PG
wyvmpi|z
pGl
nz{_WWWW^]
zt{wGz p
z
w
SGtlzS
vG
wyvmpi|z
pG
l
nz{_WWWW^\
pzkuVkzs
tV
y
{jwVpw
ST80_2013_EN_Kap04.book Seite 83 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible options
WinCC flexible /Sm@rtService
4/84 Siemens ST 80 / ST PC · 2013
4
Technical specifications
1)
The Sm@rtServer and the WinCC flexible /ProAgent option cannot be used
simultaneously on OP/TP/MP 270/370. Parallel operation of the runtime
options ProAgent, Sm@rtAccess and Sm@rtService is possible in the
context of the MP 277 8" and 10" devices, Mobile Panel 277 as well as the
MP 377. Limitation: a maximum of 2 clients can be connected with a
Sm@rtServer.
Ordering data
Order No.
1)
The "WinCC flexible /Sm@rtService for Panel" license or
"WinCC flexible /Sm@rtService for WinCC flexible Runtime" license must
be installed on the operator panels that use one of the following options:
Sm@rtServer, HTML pages, e-mail. The remote service PC and
engineering system do not require a license for configuration of the
Runtime option.
More information
Note
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about the Open Platform Program
for the creation of user-specific functions and controls for
WinCC flexible.
Type WinCC flexible /Sm@rtService
Execution platform
SIMATIC Panels Mobile Panel 177 PN,
Mobile Panel 277, TP 177B PN/DP,
OP 177B PN/DP, TP/OP 270,
TP/OP 277
SIMATIC Multi Panels MP 177, MP 270B, MP 277, MP 370,
MP 377
•PCs SIMATIC WinCC flexible Runtime
Sm@rtService
1)
Remote access via Internet Explorer V6.0 SP1 and
higher
HTML pages
for Panels/Multi Panels HTML V1.1
(no support for ActiveX, Java, ASP)
for WinCC flexible Runtime HTML V1.1
Sending emails via SMTP server
Subject, message texts with
250 characters of text per email;
date/time of message,
message No.
WinCC flexible /Sm@rtService
for SIMATIC Panels
1)
6AV6618-7BB01-3AB0
Single license, license key only
WinCC flexible /Sm@rtService for
WinCC flexible Runtime 2008
1)
6AV6618-7BD01-3AB0
Single license, license key only
ST80_2013_EN_Kap04.book Seite 84 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible options
WinCC flexible /OPC server
4/85
Siemens ST 80 / ST PC · 2013
Overview
Option for SIMATIC WinCC flexible Runtime as well as Multi
Panels for communication with applications from different
vendors (e.g. MES, ERP, or applications in the office sector)
Available for the following SIMATIC HMI systems:
- Mobile Panel 277, MP 270B, MP 277, MP 370, MP 377
(use of OPC on XML basis)
- WinCC flexible Runtime (use of OPC based on DCOM)
One license is required for each operator station.
Benefits
Incorporation of automation components from different
vendors into an automation concept
Saving of development costs through communication
between automation systems based on a homogeneous,
uniform protocol
Reduction in load on fieldbuses:
WinCC flexible Runtime as well as SIMATIC Panels permit
a control system, for example, to access the process data.
The sensitive field level is not loaded by the control level as far
as the communications requirements are concerned. The
requirements are processed by WinCC flexible Runtime and
the SIMATIC Panels.
Application
OPC (OLE for Process Control) is a standardized, open, uniform
and multi-vendor software interface. OPC is based on the
Windows technology of COM (Component Object Model),
DCOM (Distributed COM) or on XML.
Windows-based systems such as SIMATIC Panel PC or
SIMATIC Multi Panels are used for tasks at the machine and
process levels, and can communicate with all OPC-compatible
applications via Ethernet using TCP/IP and OPC. WinCC flexible
Runtime or the SIMATIC Multi Panel (OPC server) provide data
for one or more OPC clients. As a result, local visualization and
data processing are possible to the same extent as plant-wide
calling of information or archiving of process data. Uniform flows
of information guarantee an overview of the status of all
processes.
Communication with OPC-compatible applications from different
vendors (e.g. MES, ERP, or applications in the office sector) is
possible.
OPC Foundation
http://www.opcfoundation.org
Higher level visualization system
On-site visualization
OPC Client
OPC Server
3rd party
PLCs
OPC Client
OPC Server
OPC Server
3rd party
OPC Server
G_ST80_XX_00078
SIMATIC
S7-300
SIMATIC
S7-400
Multi Panel
Industrial Ethernet
PROFIBUS
ST80_2013_EN_Kap04.book Seite 85 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible options
WinCC flexible /OPC server
4/86 Siemens ST 80 / ST PC · 2013
4
Function
Use of a visualization system as a data server (OPC server) for
higher-level automation components such as control systems
or office systems
- OPC-XML server for multi panels
- OPC server (DCOM) for WinCC flexible Runtime
The WinCC flexible engineering system can conveniently
select a desired OPC item from the variables function of the
OPC server using an OPC browser (component of the OPC
server). To do this, the OPC server must be started and must
be accessible for the engineering system.
Technical specifications
1)
Data access via XML has a functional scope that is similar to OPC Data
Access. A software adapter is required that must be installed on the OPC
client PC to enable DCOM-based OPC clients to access the OPC XML
server without any modification. The software adapter is supplied with
WinCC flexible Engineering and Runtime.
Ordering data
Order No.
1)
One license is required for each operator station.
A license is not required for the engineering system for configuring the
Runtime option.
More information
Note
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about the Open Platform Program
for the creation of user-specific functions and controls for
WinCC flexible.
Type WinCC flexible /OPC Server
The specifications are maximum
values
Execution platform
SIMATIC Panels Mobile Panel 277
SIMATIC Multi Panels MP 270B, MP 277, MP 370, MP 377
•PCs SIMATIC WinCC flexible Runtime
OPC server
XML server for Multi Panels Supports the OPC XML Data
Access specification V1.0
1)
DCOM server for
WinCC flexible Runtime Supports the OPC Data Access
specification V1.0a and V2.0
• Number of connections that an
OPC server can accommodate 8
WinCC flexible /OPC Server
for SIMATIC Multi Panels
1)
6AV6618-7CC01-3AB0
Single license, license key only
WinCC flexible /OPC server
for WinCC flexible Runtime 2008
1)
6AV6618-7CD01-3AB0
Single license, license key only
ST80_2013_EN_Kap04.book Seite 86 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC flexible options
WinCC flexible /ProAgent
4/87
Siemens ST 80 / ST PC · 2013
Overview
Targeted and rapid process diagnostics in plants and
machines for SIMATIC S7 and SIMATIC HMI
Standardized diagnostics concept for various SIMATIC
components
No further configuration overhead for diagnostics functionality
Frees up PLC capacity with regard to memory and program
execution time
Note
For further information, refer to
"SIMATIC ProAgent Process Diagnostics Software".
Ordering data
Order No.
1)
One license is required for each operator station. A license is not required
for the engineering system for configuring the Runtime option.
More information
Note
Do you need a specific modification or option for the products
described here? Then look up "Customized products", where
you will find information about the Open Platform Program
for the creation of user-specific functions and controls for
WinCC flexible.
G_ST80_XX_00367
67(3
WinCC flexible /ProAgent
Software option package for
process diagnostics based on
Functional enhancement for
SIMATIC WinCC flexible; electronic
documentation in English, French,
German, Italian, and Spanish
WinCC flexible /ProAgent
for SIMATIC Panels
1)
Runtime license (Single License)
executable on Mobile Panel 277,
TP/OP/MP 270/277 and
MP 370/377
6AV6618-7DB01-3AB0
WinCC flexible/ProAgent for
WinCC flexible Runtime 2008
1)
Runtime license (single license)
6AV6618-7DD01-3AB0
ST80_2013_EN_Kap04.book Seite 87 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
4/88 Siemens ST 80 / ST PC · 2013
4
Overview
PC-based operator control and monitoring system for visual-
izing and operating processes, production flows, machines
and plants in all sectors – from the simple single-user station
through to distributed multi-user systems with redundant
servers and cross-location solutions with Web clients. WinCC
is the information hub for corporation-wide vertical integration.
The basic system configuration (WinCC basic software)
includes industry-standard functions for signaling and
acknowledging events, archiving of messages and measured
values, logging of all process and configuration data, user
administration and visualization.
The WinCC basic software forms the core of a wide range of
different applications. Based on the open programming inter-
faces, a wide range of WinCC options (from Siemens Industry
Automation) and WinCC add-ons have been developed
(by Siemens-internal and external partners).
WinCC can be operated with every PC that meets the given
HW requirements. The SIMATIC Box / Panel PC and SIMATIC
Rack PC product range in particular is available for the indus-
trial use of WinCC systems. SIMATIC PCs impress with their
powerful PC technology, are designed for round-the-clock
operation, and can be operated in both office areas and harsh
industrial environments.
SIMATIC WinCC can be ordered in combination with a
SIMATIC IPC (Box/Rack/Panel PC) as SIMATIC HMI Package
at a price advantage
Together with the SIMATIC IPC427C and IPC477C there are
turnkey solutions available as WinCC standard client or single
station (see also Packages and IPC427C/IPC477C)
Current versions:
SIMATIC WinCC V7.2
Executable with:
Windows 7 SP1 (32 / 64 bit) Professional, Enterprise, Ultimate
Windows XP Professional SP3
Windows Server 2003 SP2, Standard
Windows Server 2008 SP2 (32 bit) Standard
Windows Server 2008 R2 SP1 (64 bit) Standard
contains the Microsoft SQL Server 2008 R2 SP1 (32 bit)
SIMATIC WinCC V7.0 SP3
Executable with:
Windows 7 SP1 (32 / 64 bit) Professional, Enterprise, Ultimate
Windows XP Professional SP3
Windows Server 2003 SP2 and
Windows Server 2003 R2 SP2 Standard
Windows Server 2008 SP2 (32 bit) Standard
Windows Server 2008 R2 SP1 (64 bit) Standard
includes the Microsoft SQL Server 2005 SP4
Use in virtual environments – for additional information, see
http://support.automation.siemens.com/WW/view/en/
49370459
SIMATIC WinCC V6.2 SP3
Executable with:
Windows XP Professional SP3
Windows 2000 Professional SP4
Windows Server 2003 SP2 and Windows Server 2003 R2 SP2
include Microsoft SQL Server 2005 SP2
ST80_2013_EN_Kap04.book Seite 88 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
4/89
Siemens ST 80 / ST PC · 2013
Benefits
•All-purpose
- Solutions for all sectors
- Multilingual for worldwide usage
- Can be integrated into all automation solutions
All HMI functions on board
- User administration
- Operator control and monitoring
- Reporting, acknowledging, and archiving of events
- Acquisition, compression and archiving of measured values
(incl. long-term backup)
- Logging and documenting of process and configuration
data
Can be configured simply and efficiently
- Configuration wizards let the user focus on the essentials
- In the picture by means of cross-reference lists and screen
property displays
- Configuration of multilingual applications
- Configuring tool for configuring bulk data
Universally scalable
- Expandable from single station to client-server configura-
tions
- Increased availability by means of redundant servers
- Process visualization via the web with the
WinCC WebNavigator
Open standards for simple integration
- Powerful real-time database Microsoft SQL Server 2008 R2
SP1 (32 bit)
- Open for application modules with ActiveX controls
- Visual Basic for Applications for individual expansions
- OPC for cross-vendor communication
Process visualization with Plant Intelligence
- Integrated high-performance Historian on the basis of the
Microsoft SQL Server 2008 R2 SP1 (32 bit)
- Integrated evaluation functions for the online analysis
(statistical process control)
- Production optimization with the help of diverse options
Expandable using options and add-ons
- Options for scalable configurations
- Options for increasing the availability
- Options for IT & business integration
- Options for SCADA expansions
- Options for validation in accordance with
FDA 21 CFR Part 11
- Options for the use of telecontrol protocols
Part of Totally Integrated Automation
- Direct access to the tag and message configuration of the
SIMATIC control system
- Integrated diagnostic functions for increasing productivity
- Options for the use of telecontrol protocols
New in V7.2
Expansion into Graphic Designer
- Know-how protection by means of password protection for
PDL images and image blocks
Unicode support
- WinCC SETUP in 5 languages / up to 9 installed languages
- Individual language selection for engineering and runtime,
regardless of the language settings in the operating system
Simplified configuration of the Tag Management by means of
the innovative WinCC Configuration Studio
- Configuration options similar to those in Excel
- Simplified tags / structure tag management
New communication channels
- Communication channel to new CPU (S7-1200 / S7-1500)
(absolute address only, no CPU alarming support)
- Introduction of the OPC UA server (DA, HDA)
Expansion into archive system
- New archive recording (day, weak, year)
- New archiving methods (difference)
and more ...
ST80_2013_EN_Kap04.book Seite 89 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
4/90 Siemens ST 80 / ST PC · 2013
4
Application
SIMATIC WinCC is designed for visualization and operation of
processes, manufacturing cycles, machines and plants. With its
powerful process interface, especially to the SIMATIC family,
and the secure data archiving, WinCC enables highly available
solutions for the process control.
The sector-neutral basic system enables universal usage in all
automation applications. Sector-specific solutions can, for
example, be implemented using WinCC options (e.g. FDA
options for the pharmaceutical industry) and sector-specific
add-ons (e.g. for the water industry).
Design
SIMATIC WinCC is available as a complete package and as a
runtime package with 128, 512, 2048, 8192, 65536, 102400,
153600, 262144 PowerTags
1)
.
PowerTags are data points that are connected to controllers or
other data sources over a WinCC channel. Up to 32 alarms can
be obtained from one data point. Moreover, internal tags without
coupling are available for additional system performance. In
addition WinCC also contains 512 archive tags. Individual
archive licenses can be obtained for greater quantity structures.
Licenses for a multi-user configuration
The system software with the required number of PowerTags and
additionally the option WinCC/Server must be installed on the
WinCC server.
In the basic configuration, an RT128 or RT client license is suffi-
cient for the WinCC clients. In order to configure on clients, an
RC128 or RC client license is required. Remote configuration is
possible if WinCC clients without their own project (UniClient) on
the server project are configured.
1)
V6: 128, 256, 1024, 8192, 65536 PowerTags
Function
The powerful configuration functions of SIMATIC WinCC
contribute to a reduced engineering and training overhead and
lead to a more flexible use of personnel and greater operational
reliability. Whoever is familiar with Microsoft Windows can also
operate the WinCC Explorer, the central switching point of
WinCC.
In combination with other SIMATIC components, the system is
also equipped with auxiliary functions such as process
diagnostics and maintenance. All SIMATIC engineering tools
work together in the configuration of the functions.
SIMATIC WinCC offers a complete basic functionality for
process visualization and operation. To this end WinCC has a
number of editors and interfaces that can be used to individually
configure this functionality according to the respective appli-
cation. Expansions of a WinCC station for control tasks are also
possible with minimal engineering effort.
WinCC editors Task or configurable
runtime functionality
WinCC Explorer Central project management for the
quick access to all project data and
central settings
WinCC Graphics Designer Graphics system for user-defined
visualization and operation via pixel-
graphic objects
WinCC Alarm Logging Signaling system for detecting and
archiving events with display and
control options according to
DIN 19235; freely selectable
message classes, message display
and logging
WinCC Tag Logging Process archiving for the acquisi-
tion, compression and storage of
measured values, e.g., presentation
in trend and table format as well as
further processing
WinCC Report Designer Reporting and logging system for
time and event-controlled documen-
tation of messages, operator inputs
and current process data in the form
of user reports or project documen-
tation in an arbitrary layout
WinCC User Administrator Tool for user-friendly administration
of users and authorizations
WinCC Global Script Processing functions with limitless
functionality by means of the use of
VBScript and ANSI-C
ST80_2013_EN_Kap04.book Seite 90 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
4/91
Siemens ST 80 / ST PC · 2013
Function (continued)
Interfaces
Integration
Integration in company-wide solutions
(IT and business integration)
WinCC is strictly based on Microsoft technology, which provides
the greatest possible compatibility and integration ability.
ActiveX and .net
1)
controls support technology-specific and
industry-specific expansions. Cross-manufacturer communi-
cation is also a simple exercise. The reason: WinCC can be used
as an OPC client and server, and in addition to access to current
process values, it also supports standards such as OPC HDA
(Historical Data Access), OPC Alarm & Events, and OPC XML
Data Access.
Just as important: Visual Basic for Applications (VBA) for user-
specific expansions of the WinCC Graphics Designer and Visual
Basic Scripting (VBS) as an easy-to-learn, open runtime
language. If desired, professional application developers can
also use ANSI-C. And access to the API programming interfaces
is really simple with the Open Development Kit ODK.
WinCC integrates a powerful and scalable historian function
based on Microsoft SQL Server 2005 into the basic system.
As a result, users have every possibility: from high-performance
archiving of current process data, to long-term archiving with
high data compression, through to a central information hub in
the form of a company-wide process historian. With the help of
the Central Archive Server option, this can be set up within the
framework of a WinCC solution. Versatile clients and tools for
evaluation, the open interfaces, and special options (Connec-
tivity Pack, Connectivity Station, IndustrialDataBridge) provide
the basis for effective IT and business integration.
If external networks are accessed, suitable protective measures
(incl. IT security measures, such as network segmentation)
should be taken in order to ensure safe operation of the system.
You can find more information on the topic of Industrial Security
on the Internet at:
http://www.siemens.com/industrialsecurity
1)
Only supported in WinCC V7.0 or higher
Task or configurable
runtime functionality
Communication channels For communication with subordinate
controls (SIMATIC protocols,
PROFIBUS DP, PROFIBUS FMS,
DDE and OPC server included in
the scope of delivery)
Standard interfaces For the open integration of other
Windows applications via WinCC,
WinCC-OLE-DB, ActiveX, OLE,
DDE, OPC, etc.)
Programming ports For the individual access to data
and functions of WinCC and for the
integration in user programs with
VBA, VB Script, C-API (ODK),
C-Script (ANSI-C)
Integration in automation solutions
WinCC is an open process visualization system and provides the
option to connect the most diverse control systems.
Approved communication software
Only communication software with the listed product versions
(or higher) should be used. Corresponding SIMATIC NET
upgrades are available for upgrading older versions.
Number of connectable controls
For the number of controls connectable via Industrial Ethernet
CP 1613, the following applies to a message frame length of
512 bytes:
Via PROFIBUS, a maximum of 8 controls can be connected with
CP 5611, and a maximum of 44 controls with CP 5613. With
approx. 10 or more controls, the usage of Industrial Ethernet is
recommended.
Mixed operation with different controls
With their multi-protocol stack, the CP 1613 and CP 5613
communication processors allow parallel operation of two
protocols, such as for the mixed operation of different controls,
via a bus cable. WinCC supports the operation of two similar
interface boards only in connection with the channels
SIMATIC S5 Ethernet Layer 4 (2 x CP 1613), SIMATIC S7
Protocol Suite (2 x CP 1613, 2 x CP 5613) as well as
PROFIBUS DP (4 x CP 5613; each CP 5613 max. 122 slaves).
In addition to communication over industrial Ethernet CP 1613 or
PROFIBUS CP 5613, one CP 5611 can be used in each case for
communication with SIMATIC S7 via MPI.
Client-server communication
Communication between the clients and the server is via TCP/IP
protocol. Setting up a separate PC LAN is recommended. For
small projects with a correspondingly low incidence of message
frames, SIMATIC NET Industrial Ethernet communication can be
used for both process communication (WinCC/Server PLC)
and PC-PC communication (WinCC/client WinCC/server).
Channel DLL PROFIBUS DP
In accordance with the PROFIBUS standard, DP/slaves are
always permanently assigned to a DP master; i.e. a second
WinCC station (DP/master) cannot access the same controls
(DP/slave). This means that redundant operation of two WinCC
stations is not possible using the PROFIBUS DP connection.
Type of connection Number of nodes
SIMATIC S5
Ethernet Layer 4 + TCP/IP Up to 60
SIMATIC S7 Protocol Suite Up to 64
SIMATIC 505
Ethernet Layer 4 + TCP/IP Up to 60
ST80_2013_EN_Kap04.book Seite 91 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
4/92 Siemens ST 80 / ST PC · 2013
Integration (continued)
4
Connection to controls from other manufacturers:
OPC (OLE for Process Control) is recommended for the
connection of controls from other manufacturers.
Current notes and information about OPC servers from various
suppliers can be found at: http://www.opcfoundation.org
WinCC supports the standards:
OPC Data Access 2.05a
OPC Data Access 3.00
OPC XML Data Access 1.00
(Connectivity Pack / Connectivity Station)
OPC HDA 1.20 (Connectivity Pack / Connectivity Station)
OPC A&E 1.10 (Connectivity Pack / Connectivity Station)
OPC UA Client Data Access
OPC UA Server Data Access, HDA
(Connectivity Pack / Connectivity Station)
Connection overview
1)
WinCC version V7.2 or higher supports communication
with S7-1200 / S7-1500 CPU.
Restrictions: No symbolic address, type safe structure support
(absolute address only) No CPU alarming support
2)
Application note:
Parallel usage of the OPC client channel allows, for example, connection
to an SNMP-OPC server for visualization of the data contained there.
The SNMP OPC server enables monitoring of any network components
(such as switches) that support the SNMP protocol. You can find more
information under SIMATIC NET Communications Systems/SNMP OPC
Server.
3)
WinCC V7.0 SP3 and later supports OPC UA (United Architecture) Client
for DA.
Protocol Description
SIMATIC S7
SIMATIC S7 Protocol Suite Channel DLL for S7 functions
via MPI, PROFIBUS or
Ethernet Layer 4 + TCP/IP
SIMATIC S5
SIMATIC S5 Ethernet Layer 4 Channel DLL for S5 Layer 4
communication + TCP/IP
SIMATIC S5 Programmer Port AS511 Channel DLL and driver for serial
communication with S5 using AS511
protocol to programmers port
SIMATIC S5 Serial 3964R Channel DLL and driver for serial
communication with S5 using RK512
protocol
SIMATIC S5 PROFIBUS-FDL Channel DLL for S5-FDL
SIMATIC 505
SIMATIC 505 Serial Channel DLL and driver for serial
communication with 505 using NITP/
TBP protocol to SIMATIC 535/545/
555/565/575
SIMATIC 505 Ethernet Layer 4 Channel DLL for 505 Layer 4
communication
SIMATIC 505 TCP/IP Channel DLL for 505 TCP/IP
communication
SIMATIC S7-1200, S7-1500 (WinCC 7.2 or higher)
SIMATIC S7-1200,
S7-1500 Channel
1)
Channel DLL for S7-1200
and S7-1500 communication
Controllers from other manufacturers (from WinCC V7.0 SP3)
Allen Bradley
Ethernet IP Channel DLL and drivers for com-
munication with Allen Bradley con-
trollers via Ethernet TCP/IP using
Ethernet IP protocol
Modbus TCP/IP Channel DLL and drivers for com-
munication with Modicon controllers
via Ethernet TCP/IP using Modbus
TCP/IP protocol
Mitsubishi MC TCP/IP Channel DLL and drivers for com-
munication with Mitsubishi control-
lers via Ethernet TCP/IP using
Mitsubishi MC TCP/IP protocol
Cross-manufacturer
OPC client
1) 2)
for
DA, XML DA Channel DLL for OPC communica-
tion, WinCC can acquire data from
OPC server applications.
OPC server for
DA, XML DA, A&E, HDA Server applications for OPC com-
munication; WinCC provides pro-
cess data to OPC clients
OPC UA server for DA, HDA Server applications for OPC UA
communication
PROFIBUS FMS Channel DLL for PROFIBUS FMS
PROFIBUS DP Channel DLL for PROFIBUS DP
SIMOTION Channel DLL for SIMOTION
ST80_2013_EN_Kap04.book Seite 92 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
4/93
Siemens ST 80 / ST PC · 2013
Integration (continued)
Communications components for PG/PC for SIMATIC (for WinCC V7.2)
System interface possible
1)
Via any interface board with NDIS 3.0 interface;
no separate communication software required
2)
See ordering data for SIMATIC NET upgrade packages
3)
SIMATIC NET Version 8.2 SP1
4)
SOFTNET-S7 Lean included in scope of supply of WinCC V7.2
Industrial Ethernet SIMATIC S5
Ethernet
Layer 4
SIMATIC S5
TCP/IP SIMATIC S7
Protocol
Suite
SIMATIC 505
Ethernet
Layer 4
SIMATIC 505
TCP/IP
1)
Order No.
WinCC – channel DLL
SIMATIC S5 Ethernet Layer 4
Channel DLL for S5 Layer 4
communication + TCP/IP
• • Included in the basic
package
SIMATIC S7 Protocol Suite
Channel DLL for S7 functions Included in the basic
package
SIMATIC 505 Ethernet Layer 4
Channel DLL for 505 Layer 4
communication
Included in the basic
package
SIMATIC 505 TCP/IP
1)
Channel DLL for 505
TCP/IP communication
Included in the basic
package
Communication components for extension of the OS/OP
CP 1612
PCI card for connecting a PG/PC to
Industrial Ethernet (SOFTNET-S7 or
SOFTNET-S7 Lean communication
software must be ordered separately)
•• •6GK1161-2AA00
SOFTNET-S7
Communication software for
S7 functions (max. 64 connections)
• •
Version 8.1
2)3)
for Windows 7 (32/64-bit)
and Server 2008 R2 (64-bit)
6GK1704-1CW81-3AA0
Edition 2008 SP2 (V7.1)
2)
for Windows XP/2003 Server/(32-bit)
2008 Server
6GK1704-1CW71-3AA0
SOFTNET-S7 Lean
Communication software for S7
functions (max. 8 connections)
• •
Version 8.2 SP1
2) 4)
for Windows 7 (32/64-bit)
and Server 2008 R2 (64-bit)
6GK1704-1LW08-2AA0
Edition 2008 SP2 (V7.1)
2) 4)
for Windows XP/2003 Server / (32-bit)
2008 Server
6GK1704-1LW71-3AA0
CP 1613
PCI card for connecting a PG/PC
to Industrial Ethernet
(S7-1613 communication software
must be ordered separately)
•••••6GK1161-3AA00
CP 1613 A2
PCI card (32-bit) for connecting
a PG/PC to Industrial Ethernet
(S7-1613 communication software
required)
•••••6GK1161-3AA01
CP 1623
PCI Express X1 card (32-bit) for
connecting a PG/PC to Industrial
Ethernet (S7-1613 communication
software required)
•••••6GK1162-3AA00
S7-1613
Communication software for
S7 functions and S5/505 Layer 4
communication with TCP/IP
• • • •
Version 8.2 SP1
2)3)
for Windows 7 (32/64-bit)
and Server 2008 R2 (64-bit)
6GK1716-1CB08-2AA0
Edition 2008 SP2 (V7.1)
2)
for Windows XP/2003 Server /
(32-bit) 2008 Server
6GK1 716-1CB71-3AA0
ST80_2013_EN_Kap04.book Seite 93 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
4/94 Siemens ST 80 / ST PC · 2013
Integration (continued)
4
Communication components for PG/PC for SIMATIC (for WinCC V7.0)
• System interface possible
1)
See ordering data for SIMATIC NET upgrade package
2)
SIMATIC NET Version 8.2 SP1
PROFIBUS SIMATIC S5
PROFIBUS FDL SIMATIC S7
Protocol Suite PROFIBUS DP PROFIBUS FMS Order No.
WinCC – channel DLL
SIMATIC S5 PROFIBUS FDL
Channel DLL for S5-FDL Included in the basic
package
SIMATIC S7 Protocol Suite
Channel DLL for S7 functions Included in the basic
package
PROFIBUS DP
Channel DLL for PROFIBUS DP Included in the basic
package
PROFIBUS FMS
Channel DLL for PROFIBUS FMS Included in the basic
package
Communication components for extension of the OS/OP
CP 5611 A2
PCI card (32-bit) for connecting a
PG/PC to PROFIBUS or MPI
(communication software included in
WinCC basic package)
6GK1561-1AA01
CP 5612
2)
PCI card (32-bit) for connecting a PG/PC
to PROFIBUS (communication software
included in WinCC basic package)
6GK1561-2AA00
CP 5621
PCI Express X1 card (32-bit) for
connecting a PG/PC to PROFIBUS or
MPI (communication software included
in WinCC basic package)
6GK1562-1AA00
CP 5622
2)
PCI Express X1 card (32-bit) for
connecting a PG/PC to PROFIBUS
(communication software included in
WinCC basic package)
6GK1562-2AA00
CP 5711
2)
USB adapter for connecting a PG/PC
to PROFIBUS or MPI (communication
software included in the WinCC basic
package)
6GK1571-1AA00
CP 5512
PCMCIA card (Cardbus 32-bit) for
connecting a PG/PC to PROFIBUS or
MPI (communication software included
in WinCC basic package)
6GK1551-2AA00
ST80_2013_EN_Kap04.book Seite 94 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
4/95
Siemens ST 80 / ST PC · 2013
Integration (continued)
Communication components for PG/PC for SIMATIC (for WinCC V7.0)
• System interface possible
1)
See ordering data for SIMATIC NET upgrade package
2)
SIMATIC NET Version 8.2 SP1
PROFIBUS SIMATIC S5
PROFIBUS FDL SIMATIC S7
Protocol Suite PROFIBUS DP PROFIBUS FMS Order No.
Communication components for extension of the OS/OP (continued)
CP 5613 A2
PCI card (32-bit) for connecting a PC
to PROFIBUS (S7-5613, DP-5613 or
FMS-5613 communication software
required)
••••6GK1561-3AA01
CP 5614 A2
PCI card (32-bit) for connecting a PC
to PROFIBUS (communication software
must be ordered separately)
••••6GK1561-4AA01
CP 5623
PCI Express X1 card (32-bit) for
connecting a PG/PC to PROFIBUS or
MPI (S7-5613 communication software
or DP-5613 or FMS-5613 required)
••••6GK1562-3AA00
S7-5613 communication software for
S7 functions + FDL • •
Version 8.1
1) 2)
for Windows 7 (32/64-bit) and
Server 2008 R2 (64-bit)
6GK1713-5CB81-3AA0
Edition 2008 SP2 (V7.1)
1) 2)
for Windows XP/2003 Server /
(32-bit) 2008 Server
6GK1713-5CB71-3AA0
DP-5613
Communication software for
DP master + FDL
• •
Version 8.1
1) 2)
for Windows 7 (32/64-bit)
and Server 2008 R2 (64-bit)
6GK1713-5DB81-3AA0
Edition 2008 SP2 (V7.1)
1) 2)
for Windows XP/2003 Server /
(32-bit) 2008 Server
6GK1713-5DB71-3AA0
FMS-5613
Communication software for
PROFIBUS-FMS + FDL
• •
Edition 2008 SP2 (V7.1)
1) 2)
for Windows XP/2003 Server /
(32-bit) 2008 Server
6GK1713-5FB71-3AA0
ST80_2013_EN_Kap04.book Seite 95 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
4/96 Siemens ST 80 / ST PC · 2013
Integration (continued)
4
Communication examples
WinCC single-user system: PROFIBUS with S7 communication
WinCC single-user system: Industrial Ethernet with S7 communication
- CP 342-5 (DP, S7, S/R)
- CP 343-5 (FMS, S7, S/R)
- NCM S7 PROFIBUS manual
(SIMATIC NET CD or
Internet Download)
SIMATIC NET PROFIBUS (S7 functions)
- CP 5613 A2
- CP 5623
- S7-5613
(communication software)
Standard PC
with WinCC
e.g. RC 64 k or RT 64 k
- CP 443-5 Extended
(DP/M, S7, S/R)
- CP 443-5 Basis (FMS, S7, S/R)
- NCM S7 PROFIBUS manual
(SIMATIC NET CD or
Internet Download)
SIMATIC S7-300
PROFIBUS
SIMATIC S7-400
G_ST80_XX_00010
- CP 443-1 (S7, S/R) ISO + TCP
6GK7 443-1EX20-0XE0
- CP 443-1 Advanced
(S7, S/R, HTTP)
6GK7 443-1GX20-0XE0
- NCM S7 PROFIBUS manual
(SIMATIC NET CD or
Internet Download)
SIMATIC S7-400 SIMATIC S7-300
SIMATIC NET Industrial Ethernet (S7 functions)
Standard PC
with WinCC
e.g. RC 64 k or RT 64 k
- CP 343-1 (S7, S/R) ISO + TCP
6GK7 343-1EX30-0XE0
- CP 343-1 Advanced
(S7, S/R, HTTP)
6GK7 343-1GX30-0XE0
- NCM S7 PROFIBUS manual
(SIMATIC NET CD or
Internet Download)
- CP 1613 A2
6GK1 161-3AA01
- CP 1623
6GK1 162-3AA00
- S7-1613
(communication software)
6GK1 716-1CB80-3AA0
G_ST80_XX_00011
Industrial Ethernet
ST80_2013_EN_Kap04.book Seite 96 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
4/97
Siemens ST 80 / ST PC · 2013
Integration (continued)
WinCC single-user system: PROFIBUS FMS
WinCC multi-user system with operable server
Standard PC
with WinCC
e.g. RC 64 k or RT 64 k
+ FMS channel DLL
- CP 5613 A2
6GK1 561-3AA00
- CP 5623
6GK1 562-3AA00
- FMS-5613
(communication software)
6GK1 713-5FB80-3AA0
G_ST80_XX_00012
PROFIBUS FMS
SIMATIC NET PROFIBUS-FMS
SIMATIC S5-
115/135/155U
- CP 5431 FMS/DP
6GK1 543-1AA01
- COM 5431 FMS/DP
6GK1 745-1AD00-0EA0
SIMATIC S7-400
- CP 443-5 Basic
(FMS, S7, S/R)
6GK7 443-5FX02-0XE0
SIMATIC S7-300
- CP 343-5
(FMS, S7, S/R)
6GK7 343-5FA01-0XE0
+ TCP/IP
interface module
without
operator controls:
32 clients
+ 3 web clients
or
50 web clients
+ 1 client
Server
Client Client
This allows you to set up the following application examples
- WinCC single-user system: SIMATIC NET PROFIBUS with S7 functions
- WinCC single-user system: SIMATIC NET Industrial Ethernet with S7 functions
- WinCC single-user system: SIMATIC NET PROFIBUS-FMS
Standard PC
with WinCC
e.g. RC 64 k or RT 64 k
up to 4 clients
with operator
controls
TERMINAL BUS TCP/IP
PROCESS BUS (Industrial Ethernet/PROFIBUS)
G_ST80_XX_00013
SIMATIC S7-400 SIMATIC S7-300
ST80_2013_EN_Kap04.book Seite 97 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
4/98 Siemens ST 80 / ST PC · 2013
Integration (continued)
4
OPC link
OPC Server OPC Server
OPC Client
third-party
PLCs
OPC Server
OPC Client
- integrated
PROFIBUS
interface
- OPC Server
functionality
(OPC Server
option for
WinCC flexible
required)
- OPC Client
functionality
(included in WinCC
basic package)
- OPC Server
required for
interfacing with
third-party PLCs
- OPC Server
functionality
(included in WinCC
basic package)
- TCP-IP Interface
board required
- OPC server functionality
(included in WinCC basic package)
- TCP-IP interface board required
On-site visualization
Higher-level visualisation system
G_ST80_XX_00015
Industrial Ethernet
PROFIBUS
SIMATIC S7-400SIMATIC S7-300
ST80_2013_EN_Kap04.book Seite 98 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
4/99
Siemens ST 80 / ST PC · 2013
Technical specifications
1)
An AMD system with comparable performance can also be used
2)
Hardware requirements when using Microsoft XP Professional
Type SIMATIC WinCC V7.2 and V7.0 SP3 SIMATIC WinCC V6.2 SP3
Operating system Windows 7 (32 bit / 64 bit) Ultimate,
Professional and Enterprise
Windows XP Professional SP3
Windows 2003 Server SP2 and
Windows 2003 Server R2 SP2
Windows Server 2008 SP2 (32 bit) Standard
Windows Server 2008 R2 SP1 (64 bit) Standard
Windows XP Professional SP3,
• Windows 2000 Professional SP4,
• Windows Server 2003 SP2,
• Windows Server 2003 R2 SP2
PC hardware requirements
Processor type
1)
• Minimum Single-user station/server:
Pentium 4, 2.5 GHz
2)
Single-user station/server:
Pentium III, 1 GHz
Central Archive Server (V7.0 SP3):
Pentium 4, 2.5 GHz Central Archive Server:
Pentium 4, 2 GHz
Client:
Pentium 3, 1 GHz
2)
Client:
Pentium III, 600 MHz
WebClient/DataMonitor Client: Pentium III, 600 MHz
2)
• Recommended Single-user station/server:
Pentium 4 or Dual Core, 3 GHz
2)
Single-user station/server: Pentium 4, 2 GHz
Central Archive Server (V7.0 SP3):
Pentium 4 or Dual Core, 3 GHz Central Archive Server:
Pentium 4, 2.5 GHz
Client: Pentium 4, 2 GHz
2)
Client: Pentium III, 1 GHz
WebClient/DataMonitor Client: Pentium III, 1 GHz WebClient/DataMonitor Client: Pentium III, 1 GHz
RAM
• Minimum Single-user station/server: 4 GB
2)
Single-user station: 512 MB, server: 1 GB
Central Archive Server: 4 GB Central Archive Server: 1 GB
Client: 1 GB
2)
Client: 512 MB
WebClient/DataMonitor Client: 512 MB
2)
WebClient/DataMonitor Client: 256 MB
• Recommended Single-user station/server: 8 GB
2)
Single-user station: >= 1 GB,
server: >1 GB
Central Archive Server: 4GB Central Archive Server: 2GB
Client: 2 GB
2)
Client: 512 MB
WebClient/DataMonitor Client: 1 GB
2)
WebClient/DataMonitor Client: 512 MB
Graphics card
• Minimum 16 MB, 800 x 600
2)
16 MB, 800 x 600
• Recommended 32 MB, 1280 x 1024
2)
32 MB, 1280 x 1024
Hard disk
• Minimum Single-user station/server: 80 GB Single-user station/server: 20 GB
Client: 20 GB Client: 5 GB
Central Archive Server: 40 GB Central Archive Server: 40 GB
WebClient/DataMonitor Client: 5 GB WebClient/DataMonitor Client: 5 GB
• Recommended Single-user station/server: 160 GB Single-user station/server: 80 GB
Client: 40 GB Client: 20 GB
Central Archive Server: 2 x 80 GB Central Archive Server: 2 x 80 GB
WebClient/DataMonitor Client: 10 GB WebClient/DataMonitor Client: 10 GB
Hard disk
(available memory for installation)
-Minimum Server: >1.5 GB Server: 1.5 GB
Client: 1.5 GB Client: 1 GB
- Recommended Server: >10 GB Server: >10 GB
Client: >1.5 GB Client: >1.5 GB
CD-ROM/DVD-ROM/disk drive/
USB port for software installation for software installation
ST80_2013_EN_Kap04.book Seite 99 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
4/100 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
4
1)
Dependent on the available storage space
2)
Dependent on the number of licensed archive variables
3)
Dependent on number of licensed PowerTags
4)
Asian versions for Version 7 SP1 or higher
5)
The number of variables per report is dependent on process communi-
cation performance
Type SIMATIC WinCC
Functionality/
quantity structure
Number of messages 150,000
Message text (number of characters) 10 x 256
Message archive > 500,000 messages
1)
Process values per message 10
• Constant load of messages, max. Central Archive Server: 100/sec
Server/single-user station: 10/s
•Message burst, max. Server/single-user station:
2,000/10 s every 5 min
Archives
Archive data points Max. 120,000 per server
2)
Archive types Short-term archive with and
without long-term archiving
Data storage format Microsoft SQL Server 2005
• Measured values per second, max. Server/single-user station: 5,000/s
User archive
Archives and views 500 each
Product consisting of data record
and column per user archive 320,000
Fields per user archive 500
Graphics system
Number of screens System-limited
1)
Number of objects per screen System-limited
1)
Number of controllable fields per
screen System-limited
1)
PowerTags 256 K
3)
Trends
• Trend views per image 25
Trends per trend view 80
User administration
• User groups 128
• Number of users 128
• Authorization groups 999
Configuration languages 5 European (Eng., Fr., Ger., It., Sp.),
4 Asian (simpl.+trad. Chi/Kor/Jpn)
4)
Protocols
• Message sequence reports
(simultaneously) 1 per server/single-user station
• Message archive reports
(simultaneously) 3
•User reports System-limited
1)
• Report lines per group 66
• Variables per report 300
5)
Multi-user system
• Server 18
• Clients for server
with operator station 4
• Clients for server
without operator station 32 clients + 3 WebClients or
50 WebClients + 1 client
Type SIMATIC WinCC
ST80_2013_EN_Kap04.book Seite 100 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
4/101
Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
1)
According to licensing provisions, 1 upgrade package must be ordered for
each WinCC station
2)
The Software Update Service is valid for 1 year. The contract is automati-
cally extended by 1 more year unless canceled 3 months prior to
expiration. According to licensing provisions, 1 Software Update Service
must be ordered for each WinCC station.
3)
Requires the current software version
SIMATIC WinCC system software
V7.2
Runtime packages on DVD
Language/script versions: De, En,
Fr, It, Es; with license for
• WinCC RT Client 6AV6381-2CA07-2AX0
• 128 PowerTags (RT 128) 6AV6381-2BC07-2AX0
• 512 PowerTags (RT 512) 6AV6381-2BD07-2AX0
2048 PowerTags (RT 2048) 6AV6381-2BE07-2AX0
8192 PowerTags (RT 8192) 6AV6381-2BH07-2AX0
65536 PowerTags (RT 65536) 6AV6381-2BF07-2AX0
102400 PowerTags (RT 102400) 6AV6381-2BJ07-2AX0
153600 PowerTags (RT 153600) 6AV6381-2BK07-2AX0
262144 PowerTags (RT 262144) 6AV6381-2BL07-2AX0
Including 512 archive tags each
Complete packages on DVD
Language versions: De, En, Fr, It,
Es; with license for
• WinCC RC Client 6AV6381-2CB07-2AX0
• 128 PowerTags (RC 128) 6AV6381-2BM07-2AX0
• 512 PowerTags (RC 512) 6AV6381-2BN07-2AX0
2048 PowerTags (RC 2048) 6AV6381-2BP07-2AX0
8192 PowerTags (RC 8192) 6AV6381-2BS07-2AX0
65536 PowerTags (RC 65536) 6AV6381-2BQ07-2AX0
102400 PowerTags (RC 102400) 6AV6381-2BT07-2AX0
153600 PowerTags (RC 153600) 6AV6381-2BU07-2AX0
262144 PowerTags (RC 262144) 6AV6381-2BV07-2AX0
SIMATIC WinCC system software
V7.2 ASIA
Runtime packages on DVD
Language/script versions: En, Chs,
Cht, Kor, Jpn; with license for
• WinCC RT Client 6AV6381-2CA07-2AV0
• 128 PowerTags (RT 128) 6AV6381-2BC07-2AV0
• 512 PowerTags (RT 512) 6AV6381-2BD07-2AV0
2048 PowerTags (RT 2048) 6AV6381-2BE07-2AV0
8192 PowerTags (RT 8192) 6AV6381-2BH07-2AV0
65536 PowerTags (RT 65536) 6AV6381-2BF07-2AV0
102400 PowerTags (RT 102400) 6AV6381-2BJ07-2AV0
153600 PowerTags (RT 153600) 6AV6381-2BK07-2AV0
262144 PowerTags (RT 262144) 6AV6381-2BL07-2AV0
Including 512 archive tags each
Complete packages on DVD
Language versions: EN, CHS, CHT,
KOR, JPN; with license for
• WinCC RC Client 6AV6381-2CB07-2AV0
• 128 PowerTags (RC 128) 6AV6381-2BM07-2AV0
• 512 PowerTags (RC 512) 6AV6381-2BN07-2AV0
2048 PowerTags (RC 2048) 6AV6381-2BP07-2AV0
8192 PowerTags (RC 8192) 6AV6381-2BS07-2AV0
65536 PowerTags (RC 65536) 6AV6381-2BQ07-2AV0
102400 PowerTags (RC 102400) 6AV6381-2BT07-2AV0
153600 PowerTags (RC 153600) 6AV6381-2BU07-2AV0
262144 PowerTags (RC 262144) 6AV6381-2BV07-2AV0
Clients
• RT Client ASIA 6AV6381-2CA07-2AV0
• RT Client 6AV6381-2CA07-2AX0
RC Client ASIA 6AV6381-2CB07-2AV0
RC Client 6AV6381-2CB07-2AX0
SIMATIC WinCC V7.2 Powerpacks
For upgrading from:
Runtime packages
• 128 to 512 PowerTags 6AV6371-2BD07-2AX0
• 512 to 2048 PowerTags 6AV6371-2BG07-2AX0
• 2048 to 8192 PowerTags 6AV6371-2BM07-2AX0
• 8192 to 65536 PowerTags 6AV6371-2BN07-2AX0
• 65536 to 102400 PowerTags 6AV6371-2BP07-2AX0
• 102400 to 153600 PowerTags 6AV6371-2BQ07-2AX0
• 153600 to 262144 PowerTags 6AV6371-2BR07-2AX0
Complete packages
• 128 to 512 PowerTags 6AV6371-2BD17-2AX0
• 512 to 2048 PowerTags 6AV6371-2BG17-2AX0
• 2048 to 8192 PowerTags 6AV6371-2BM17-2AX0
• 8192 to 65536 PowerTags 6AV6371-2BN17-2AX0
• 65536 to 102400 PowerTags 6AV6371-2BP17-2AX0
• 102400 to 153600 PowerTags 6AV6371-2BQ17-2AX0
• 153600 to 262144 PowerTags 6AV6371-2BR17-2AX0
SIMATIC WinCC V7.2 archives
• 1500 archives 6AV6371-1DQ17-2AX0
• 5000 archives 6AV6371-1DQ17-2BX0
• 10000 archives 6AV6371-1DQ17-2CX0
• 30000 archives 6AV6371-1DQ17-2EX0
• 80000 archives 6AV6371-1DQ17-2GX0
SIMATIC WinCC V7.2
archive powerpacks
For upgrading archiving from
• 1500 to 5000 archive tags 6AV6371-1DQ17-2AB0
• 5000 to 10000 archive tags 6AV6371-1DQ17-2BC0
• 10000 to 30000 archive tags 6AV6371-1DQ17-2CE0
• 30000 to 80000 archive tags 6AV6371-1DQ17-2EG0
SIMATIC WinCC Upgrade/
Software Update Service
SIMATIC WinCC V7.2 upgrade
1)
For upgrading the RT version
from V6.2 to V7.2 6AV6381-2AA07-2AX4
from V7.0 to V7.2 6AV6381-2AA07-2AX3
from V6.2 ASIA to V7.2 ASIA 6AV6381-2AA07-2AV4
from V7.0 ASIA to V7.2 ASIA 6AV6381-2AA07-2AV3
For upgrading the Client RT version
from V6.2 to V7.2 6AV6381-2BC07-2AX4
from V7.0 to V7.2 6AV6381-2BC07-2AX3
from V6.2 ASIA to V7.2 ASIA 6AV6381-2BC07-2AV4
from V7.0 ASIA to V7.2 ASIA 6AV6381-2BC07-2AV3
For upgrading the RC version
from V6.2 to V7.2 6AV6381-2AB07-2AX4
from V7.0 to V7.2 6AV6381-2AB07-2AX3
from V6.2 ASIA to V7.2 ASIA 6AV6381-2AB07-2AV4
from V7.0 ASIA to V7.2 ASIA 6AV6381-2AB07-2AV3
SIMATIC WinCC Software Update
Service (SUS)
2) 3)
SIMATIC WinCC V7 Update
Software Update Service for
WinCC basic software and options:
• 1 license 6AV6381-1AA00-0AX5
• 3 licenses 6AV6381-1AA00-0BX5
• 10 licenses 6AV6381-1AA00-0CX5
ST80_2013_EN_Kap04.book Seite 101 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
4/102 Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
4
1)
According to licensing provisions, 1 upgrade package must be ordered for
each WinCC station.
SIMATIC WinCC system software
V6.2 SP3
Runtime packages on CD-ROM
Language/script versions:
DE/EN/FR/IT/ES; with license for
• 128 PowerTags (RT 128) 6AV6381-1BC06-2AX0
• 256 PowerTags (RT 256) 6AV6381-1BD06-2AX0
1024 PowerTags (RT 1024) 6AV6381-1BE06-2AX0
8192 PowerTags (RT 8192) 6AV6381-1BH06-2AX0
65536 PowerTags (RT 65536) 6AV6381-1BF06-2AX0
102400 PowerTags (RT 102400) 6AV6381-1BJ06-2AX0
153600 PowerTags (RT 153600) 6AV6381-1BK06-2AX0
262144 PowerTags (RT 262144) 6AV6381-1BL06-2AX0
Including 512 archive tags each
Complete packages on CD-ROM
Language versions:
DE/EN/FR/IT/ES; with license for
• 128 PowerTags (RC 128) 6AV6381-1BM06-2AX0
• 256 PowerTags (RC 256) 6AV6381-1BN06-2AX0
1024 PowerTags (RC 1024) 6AV6381-1BP06-2AX0
8192 PowerTags (RC 8192) 6AV6381-1BS06-2AX0
65536 PowerTags (RC 65536) 6AV6381-1BQ06-2AX0
102400 PowerTags (RC 102400) 6AV6381-1BT06-2AX0
153600 PowerTags (RC 153600) 6AV6381-1BU06-2AX0
262144 PowerTags (RC 262144) 6AV6381-1BV06-2AX0
Including 512 archive tags each
SIMATIC WinCC system software
V6.2 SP3 ASIA
Runtime packages on CD-ROM
Language versions: English/simpli-
fied and traditional Chinese/Korean/
Taiwanese/Japanese; with license
for
• 128 PowerTags (RT 128) 6AV6381-1BC06-2AV0
• 256 PowerTags (RT 256) 6AV6381-1BD06-2AV0
1024 PowerTags (RT 1024) 6AV6381-1BE06-2AV0
8192 PowerTags (RT 8192) 6AV6381-1BH06-2AV0
65536 PowerTags (RT 65536) 6AV6381-1BF06-2AV0
Including 512 archive tags each
Complete packages on CD-ROM
Language versions: English/simpli-
fied and traditional Chinese/Korean/
Taiwanese, Japanese; with license
for
• 128 PowerTags (RC 128) 6AV6381-1BM06-2AV0
• 256 PowerTags (RC 256) 6AV6381-1BN06-2AV0
1024 PowerTags (RC 1024) 6AV6381-1BP06-2AV0
8192 PowerTags (RC 8192) 6AV6381-1BS06-2AV0
65536 PowerTags (RC 65536) 6AV6381-1BQ06-2AV0
Including 512 archive tags each
SIMATIC WinCC V6.2 Powerpacks
For upgrading from:
Runtime packages
• 128 to 256 PowerTags 6AV6371-1BD06-2AX0
• 128 to 1024 PowerTags 6AV6371-1BE06-2AX0
• 128 to 8192 PowerTags 6AV6371-1BK06-2AX0
• 128 to 65536 PowerTags 6AV6371-1BF06-2AX0
• 256 to 1024 PowerTags 6AV6371-1BG06-2AX0
• 256 to 8192 PowerTags 6AV6371-1BL06-2AX0
• 256 to 65536 PowerTags 6AV6371-1BH06-2AX0
• 1024 to 8192 PowerTags 6AV6371-1BM06-2AX0
• 1024 to 65536 PowerTags 6AV6371-1BJ06-2AX0
• 8192 to 65536 PowerTags 6AV6371-1BN06-2AX0
Complete packages
• 128 to 256 PowerTags 6AV6371-1BD16-2AX0
• 128 to 1024 PowerTags 6AV6371-1BE16-2AX0
• 128 to 8192 PowerTags 6AV6371-1BK16-2AX0
• 128 to 65536 PowerTags 6AV6371-1BF16-2AX0
• 256 to 1024 PowerTags 6AV6371-1BG16-2AX0
• 256 to 8192 PowerTags 6AV6371-1BL16-2AX0
• 256 to 65536 PowerTags 6AV6371-1BH16-2AX0
• 1024 to 8192 PowerTags 6AV6371-1BM16-2AX0
• 1024 to 65536 PowerTags 6AV6371-1BJ16-2AX0
• 8192 to 65536 PowerTags 6AV6371-1BN16-2AX0
SIMATIC WinCC V6.2 Archive
• 1500 archives 6AV6371-1DQ16-2AX0
• 5000 archives 6AV6371-1DQ16-2BX0
• 10000 archives 6AV6371-1DQ16-2CX0
• 30000 archives 6AV6371-1DQ16-2EX0
• 80000 archives 6AV6371-1DQ16-2GX0
• 120000 archives 6AV6371-1DQ16-2JX0
SIMATIC WinCC V6.2
Archive Powerpacks
For upgrading archiving from
• 1500 to 5000 archive tags 6AV6371-1DQ16-2AB0
• 5000 to 10000 archive tags 6AV6371-1DQ16-2BC0
• 10000 to 30000 archive tags 6AV6371-1DQ16-2CE0
• 30000 to 80000 archive tags 6AV6371-1DQ16-2EG0
• 80000 to 120000 archive tags 6AV6371-1DQ16-2GJ0
SIMATIC WinCC V6.2 upgrade
1)
For upgrading the RT version
• from V5.x to V6.2 SP3 6AV6381-1AA06-2AX4
• from V6.x to V6.2 SP3 6AV6381-1AA06-2AX3
• from V5.x ASIA to V6.2 SP3 ASIA 6AV6381-1AA06-2AV4
• from V6.x ASIA to V6.2 SP3 ASIA 6AV6381-1AA06-2AV3
For upgrading the RC version
• from V5.x to V6.2 SP3 6AV6381-1AB06-2AX4
• from V6.x to V6.2 SP3 6AV6381-1AB06-2AX3
• from V5.x ASIA to V6.2 SP3 ASIA 6AV6381-1AB06-2AV4
• from V6.x ASIA to V6.2 SP3 ASIA 6AV6381-1AB06-2AV3
ST80_2013_EN_Kap04.book Seite 102 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
4/103
Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
SIMATIC WinCC V7.2
communication
Communication via
Industrial Ethernet
CP 1612 A2 6GK1161-2AA01
PCI card (32-bit) for connection of a
programming device or PC to Indus-
trial Ethernet (10/100/1000 Mbps)
with RJ45 connection via
SOFTNET S7 and SOFTNET PG
SOFTNET-IE S7 Version 8.2 SP1
1)
Software for S7-compatible and
S5-compatible communication incl.
OPC server, PG/OP communication
and NCM PC; up to 64 connections;
single license for one installation of
Runtime software, software and
electronic manual on CD-ROM;
license key on USB stick; Class A
for CP 1612-A2 English/German
Single license for 1 installation 6GK1704-1CW08-2AA0
Upgrade package for SIMATIC NET
Edition 2006 or higher 6GK1704-1CW00-3AE0
Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2 and
Edition 2005
6GK1704-1CW00-3AE1
SOFTNET-IE S7 Lean
Version 8.2 SP1
(license included in scope of
delivery of WinCC V7.2)
Software for S7-compatible and
S5-compatible communication incl.
OPC server, PG/OP communication
and NCM PC; up to 8 connections;
single license for one installation of
Runtime software, software and
electronic manual on CD-ROM;
license key on USB stick; Class A
for CP 1612-A2 English/German
Single license for 1 installation 6GK1704-1LW81-3AA0
Upgrade package for SIMATIC NET
Edition 2006 or higher 6GK1704-1LW00-3AE0
Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2 and
Edition 2005
6GK1704-1LW00-3AE1
CP 1613 A2 6GK1161-3AA01
PCI card (32-bit) for connecting a
PG/PC to Industrial Ethernet (com-
munications software must be
ordered separately)
CP 1623 6GK1162-3AA00
PCI Express X1 card (32-bit) for
connection of PG/PC to Industrial
Ethernet (communications software
must be ordered separately)
CP 1628 6GK1162-8AA00
PCI Express X1 card (32-bit) for
connection of PG/PC to Industrial
Ethernet (communications software
must be ordered separately)
1)
According to licensing provisions, 1 upgrade package must be ordered for
each WinCC station
2)
The Software Update Service is valid for 1 year. The contract is automati-
cally extended by 1 more year unless canceled 3 months prior to
expiration. According to licensing provisions, 1 Software Update Service
must be ordered for each WinCC station.
HARDNET-IE S7 V8.2 SP1
1)
Software for S7-compatible and
S5-compatible communication
incl. OPC server,
PG/OP communication and
NCM PC,
single license for one installation of
Runtime software,
software and electronic manual on
CD-ROM,
license key on USB stick, Class A
for CP 1613-A2, CP 1623, CP 1628;
English/German
• Single license for 1 installation 6GK1716-1CB08-2AA0
• Upgrade package for SIMATIC NET
Edition 2006 or higher 6GK1716-1CB00-3AE0
• Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2 and
Edition 2005
6GK1716-1CB00-3AE1
Communication via PROFIBUS
CP 5611 A2 6GK1561-1AA01
PCI card (32-bit) for connecting a
PG/PC to PROFIBUS (communica-
tions software included in the
WinCC basic package)
CP 5612
2)
6GK1561-2AA00
PCI card (32-bit) for connecting a
PG/PC to PROFIBUS (communica-
tions software included in the
WinCC basic package)
CP 5621 6GK1562-1AA00
PCI Express X1 card (32-bit) for
connection of PG/PC to PROFIBUS
(communications software included
in WinCC basic package)
CP 5622
2)
6GK1562-2AA00
PCI Express X1 card (32-bit) for
connecting a PG/PC to PROFIBUS
(communications software included
in WinCC basic package)
CP 5711 6GK1571-1AA00
USB adapter for connecting a
PG/PC to PROFIBUS or MPI
(communications software included
in WinCC basic package)
CP 5512 6GK1551-2AA00
PCMCIA card (CARDBUS 32-bit) for
the connection of a PG/notebook to
PROFIBUS or MPI (communications
software included in WinCC basic
package)
CP 5613 A2 6GK1561-3AA01
PCI card (32-bit) for connecting a
PC to PROFIBUS (communications
software must be ordered sepa-
rately)
ST80_2013_EN_Kap04.book Seite 103 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
4/104 Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
4
Communication via PROFIBUS
(continued)
CP 5614 A2 6GK1561-4AA01
PCI card (32-bit) for connecting a
PC to PROFIBUS (communications
software must be ordered sepa-
rately)
CP 5623 6GK1562-3AA00
PCI Express X1 card (32-bit) for
connection of PG/PC to Industrial
Ethernet (communications software
must be ordered separately)
HARDNET-PB S7 V8.2 SP1
1)
Software for S7 communication incl.
PG/OP communication, FDL, OPC
server, Runtime software, software
and electronic manual on CD-ROM,
license key on USB stick, Class A
for CP 5613-A2, CP 5614-A2,
CP 5623
English/German
Single license for 1 installation 6GK1713-5CB08-2AA0
Upgrade package for SIMATIC NET
Edition 2006 or higher 6GK1713-5CB00-3AE0
Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2 and
Edition 2005
6GK1713-5CB00-3AE1
HARDNET-PB DP V8.2 SP1
1)
Software for DP protocol incl.
PG/OP communication, FDL, DP
OPC server,
Runtime software, software and
electronic manual on CD-ROM,
license key on USB stick, Class A,
for CP 5613-A2, CP 5614-A2,
CP 5623; English/German
Single license for 1 installation 6GK1713-5DB08-2AA0
Upgrade package for SIMATIC NET
Edition 2006 or higher 6GK1713-5DB00-3AE0
Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2 and
Edition 2005
6GK1713-5DB00-3AE1
FMS-5613 V7.1 SP6
(Edition 2008+SP6)
1)
Software for FMS protocol incl.
PG/OP communication, FDL,
OPC server,
Runtime software, software and
electronic manual on CD-ROM,
license key on USB stick, Class A;
for CP 5613-A2, CP 5614-A2,
CP 5623; English/German
Single license for 1 installation 6GK1713-5FB71-3AA0
Upgrade package for SIMATIC NET
Edition 2006 or higher 6GK1713-5FB00-3AE0
Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2 and
Edition 2005
6GK1713-5FB00-3AE1
1)
According to licensing provisions, 1 upgrade package must be ordered for
each WinCC station
SIMATIC WinCC V6.2
communication
Communication via
Industrial Ethernet
CP 1612 A2 6GK1161-2AA01
PCI card (32-bit) for connecting
a PG/PC to Industrial Ethernet
(SOFTNET-S7 must be ordered
separately)
SOFTNET-S7 V7.1 SP6
(Edition 2008+SP6)
1)
Software for S7-compatible and
S5-compatible communication
incl. OPC server,
PG/OP communication and
NCM PC; up to 64 connections;
single license for one installation
of Runtime software,
software and electronic manual on
CD-ROM,
license key on USB stick, Class A,
for CP 1612-A2, English/German
• Single license for 1 installation 6GK1704-1CW71-3AA0
• Upgrade package for
SIMATIC NET Edition 2007
Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2,
and Edition 2005
1)
6GK1704-1CW00-3AE1
SOFTNET-S7 Lean V7.1 SP6
(Edition 2008+SP6)
1)
(license included in scope of
delivery of WinCC V6.2)
Software for S7-compatible and
S5-compatible communication
incl. OPC server,
PG/OP communication and
NCM PC; up to 8 connections;
single license for one installation
of Runtime software,
software and electronic manual on
CD-ROM,
license key on USB stick, Class A,
for CP 1612-A2, English/German
• Single license for 1 installation 6GK1704-1LW71-3AA0
• Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2 and
Edition 2005
1)
6GK1704-1LW00-3AE1
CP 1613 A2 6GK1161-3AA01
PCI card (32-bit) for connecting a
PG/PC to Industrial Ethernet (com-
munications software must be
ordered separately)
S7-1613 V7.1 SP6
(Edition 2008+SP6)
1)
Software for S7-compatible and
S5-compatible communication
incl. PG/OP communication,
OPC server and NCM PC;
single license for one installation
of Runtime software,
software and electronic manual on
CD-ROM,
license key on USB stick, Class A
for CP 1613-A2; English/German
• Single license for 1 installation 6GK1716-1CB71-3AA0
• Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2 and
Edition 2005
1)
6GK1716-1CB00-3AE1
ST80_2013_EN_Kap04.book Seite 104 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
4/105
Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
Hardware for process control functions
Note
For further information on control technology options see
Catalog ST PCS7.
Communication via
Industrial Ethernet
T7-1613 V7.1 SP6
(Edition 2008+SP6)
1)
Software for TF protocol, S5-com-
patible communication incl. OPC,
PG/OP communication (S5/505
layer 4 communication with TCP/IP)
single license for one installation of
Runtime software, software and
electronic manual on CD-ROM,
license key on USB stick; Class A
for CP 1613-A2 English/German
Single license 6GK1716-1TB71-3AA0
Upgrade package for
SIMATIC NET Edition 2007
Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2,
and Edition 2005
1)
6GK1716-1CB00-3AE1
Communication via PROFIBUS
CP 5611 A2 6GK1561-1AA01
PCI card (32-bit) for connecting a
PG/PC to PROFIBUS (communica-
tions software included in the
WinCC basic package)
CP 5621 6GK1562-1AA00
PCI Express X1 card (32-bit) for
connection of PG/PC to PROFIBUS
(communications software included
in WinCC basic package)
CP 5611 MPI 6GK1561-1AM01
Comprising CP 5611 A2 and
MPI cable, 5 m
CP 5621 MPI 6GK1562-1AM00
Comprising CP 5621 (32-bit) and
MPI cable, 5 m
CP 5512 6GK1551-2AA00
PCMCIA card (CARDBUS 32-bit) for
the connection of a PG/notebook to
PROFIBUS or MPI (communications
software included in WinCC basic
package)
CP 5613 A2 6GK1561-3AA01
PCI card (32-bit) for connecting a
PC to PROFIBUS (communications
software must be ordered sepa-
rately)
CP 5614-A2 6GK1561-4AA01
PCI Card (32-Bit) for connecting a
PC to PROFIBUS (communications
software must be ordered sepa-
rately)
1)
The SIMATIC NET PC software delivered with SIMATIC WinCC V7.2
must always be used. The scope of supply for WinCC V7.2 includes the
SIMATIC NET PC software V8.2 SP1 / supported operating systems:
32/64-bit Windows 7 Professional, Ultimate, 64-bit Windows Server 2008
R2 and SIMATIC NET PC Software V7.1 SP6 (Edition 2008+SP6) /
supported operating systems: 32-bit Windows XP Professional, Windows
Vista Professional, Ultimate, Windows Server 2003, Windows Server 2008
Standard.
Only the license is to be used from the scope of supply of the
above-listed SIMATIC NET PC software products. The licenses supplied
with SIMATIC NET V8.2 SP1 are valid for all older versions up to and
including Edition 2006.
S7-5613 V7.1 SP6
(Edition 2008 SP6)
Software for S7 communication incl.
PG/OP communication, FDL, OPC
server; for Windows XP Professional/
2003 Server/2000 Professional/
Server for CP 5613/CP 5614;
English/German
• Single license for 1 installation 6GK1713-5CB71-3AA0
• Upgrade package
for SIMATIC NET Edition 2007
Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2,
and Edition 2005
1)
6GK1713-5CB00-3AE1
DP-5613 V7.1 SP6
(Edition 2008 + SP6)
Software for DP protocol incl. PG/OP
communication, FDL, OPC server,
Runtime software, software and
electronic manual on CD-ROM,
license key on USB flash drive,
Class A, for 32-bit: Windows XP
Professional, Windows 2003 Server,
Windows VISTA Ultimate/Business;
for CP 5613 A2; English/German
• Single license for 1 installation 6GK1713-5DB71-3AA0
• Upgrade package
for SIMATIC NET Edition 2007
Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2,
and Edition 2005
1)
6GK1713-5DB00-3AE1
FMS-5613 V7.1 SP6
(Edition 2008 + SP6)
Software for FMS protocol incl.
PG/OP communication, FDL,
FMS-OPC server, for Windows XP
Professional/2003 Server/2000
Professional/Server for
CP 5613/CP 5614; English/German
• Single license for 1 installation 6GK1713-5FB71-3AA0
• Upgrade package for
SIMATIC NET Edition 2007
Upgrade package for
SIMATIC NET V6.0, V6.1, V6.2,
and Edition 2005
1)
6GK1713-5FB00-3AE1
DCF-77 receiver
for time synchronization
• DCF77 (Europe) 2XV9450-1AR14
ST80_2013_EN_Kap04.book Seite 105 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SCADA system SIMATIC WinCC
SIMATIC WinCC
4/106 Siemens ST 80 / ST PC · 2013
4
More information
WinCC language versions
SIMATIC WinCC is also offered in simplified Chinese, traditional
Chinese, Korean and Japanese especially for Asian markets.
These WinCC versions are intended for machine manufacturers,
plant constructors and exporters who supply the regions of
China, Taiwan, Korea and Japan.
WinCC ASIA includes all familiar WinCC functions and offers in
addition the configuration user interface in the respective
national language and English. The online help is available in
simplified Chinese, traditional Chinese, Korean, Japanese and
English. A Chinese, Korean, Japanese or multilingual Windows
operating system is required for operation.
WinCC ASIA is delivered on a separate DVD which contains all
of the above mentioned language versions. The corresponding
documentation can be obtained from the national subsidiaries in
China, Korea, Taiwan and Japan.
The runtime licenses are language-neutral. The English handling
program (Automation License Manager – ALM) is executable
under the Chinese, Korean and Japanese Windows versions.
In order to use the Asian languages in WinCC, an Asia hardware
dongle is required.
Additional information is available on the Internet at:
http://www.siemens.com/wincc
Separate configurators are available for PC hardware:
SIMATIC IPC547C, SIMATIC Rack PC 547B
SIMATIC IPC647C, SIMATIC Rack PC 647B
SIMATIC IPC847C, SIMATIC Rack PC 847B
SIMATIC IPC427C
SIMATIC IPC627C, SIMATIC Box PC 627B
SIMATIC Box PC 827B
SIMATIC HMI IPC577C, SIMATIC Panel PC 577B
SIMATIC HMI IPC677C, SIMATIC Panel PC 677B
ST80_2013_EN_Kap04.book Seite 106 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
SIMATIC WinCC options
4/107
Siemens ST 80 / ST PC · 2013
Overview
The universal WinCC basic software is the basis for modular
expansions. These functional expansions can be obtained in the
form of WinCC options and as WinCC Premium add-ons.
WinCC options are created by WinCC Development and are
Siemens Industry Automation products. You can obtain support
from our Advisory Services and via the central hotline.
Options for scalable plant configurations
•WinCC/Server
For configuring a powerful client/server system
WinCC/Web Navigator
For controlling and monitoring plants via the Internet,
in-house intranet or LAN
WinCC/TeleControl
For connecting to outlying stations (remote terminal units =
RTUs) via telecontrol protocols in a WinCC SCADA system.
SIMATIC ProcessHistorian
Central scalable long-term archive for the whole plant
Options for increasing the availability
• WinCC/Redundancy
For increasing system availability through redundancy
SIMATIC Maintenance Station
For system-integrated diagnostics and plant asset
management
• WinCC/ProAgent
For reliable process diagnostics
Options for IT and Business Integration – Plant Intelligence
SIMATIC InformationServer
Web-based, integrated reporting from production to
management, based on archived data
WinCC/DataMonitor
For displaying and evaluating current process states and
historical data on office PCs with standard tools
• WinCC/DowntimeMonitor
For detecting and analyzing downtimes for machines and
plants
WinCC/Connectivity Pack
Access to WinCC archives via OPC HDA, OPC A&E,
OPC XML Server and WinCC OLE-DB /OLE-DB
WinCC/Connectivity Station
Gateway to WinCC server data over OPC HDA, OPC A&E,
OPC XML server and WinCC OLE-DB /OLE-DB from
independent computers
• WinCC/IndustrialDataBridge
Configurable connection to databases and IT systems
Options for SCADA expansions
WinCC/User Archives
For managing data records in user archives
WinCC/Calendar Scheduler
Calendar-based planning of events
WinCC/Event Notifier
For sending of notifications depending on specific events in
the WinCC message system
Options for sector-specific expansions
WinCC/ChangeControl
- Change and version management
- Generation of audit trails for engineering
WinCC/Audit
- Change management
- Generation of audit trails for engineering and runtime
SIMATIC Logon
- Central management of WinCC users, plant-wide
(to CFR 21 Part 11)
Options for individual system expansions
WinCC/IndustrialX
1)
For creating customized WinCC ActiveX objects in a
VB development environment
WinCC/ODK (Open Development Kit)
For the use of open programming interfaces
1)
For WinCC V7.2, the option WinCC/IndustrialX is part of the option
WinCC/ODK.
More information
WinCC options
http://www.siemens.com/wincc/options
G_ST80_XX_00175
WinCC
Basis-SW
RC, RT
WinCC
Add-on
WinCC
Option
WinCC
Option
WinCC
Option
WinCC
Add-on
WinCC
Add-on
ST80_2013_EN_Kap04.book Seite 107 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
SIMATIC BATCH for WinCC
4/108 Siemens ST 80 / ST PC · 2013
4
Overview
WinCC in connection with the SIMATIC BATCH product range
offers a solution for the implementation of batch processes in
accordance with ISA S88.
SIMATIC BATCH for WinCC is of particular interest where
different PLCs such as S7-400/300, S5 or non-Siemens PLCs
are to be used in a BATCH system.
SIMATIC BATCH for WinCC is offered as a bundle that
includes the SIMATIC BATCH components as well as the
WinCC components.
SIMATIC BATCH for WinCC contains the software for
SIMATIC BATCH including options, as well as for
SIMATIC WinCC including options. These products are
released for any combinations.
- SIMATIC BATCH for WinCC includes the licenses
SIMATIC BATCH Server (10 units
1)
), SIMATIC BATCH CC,
and SIMATIC BATCH Recipe.
- All other SIMATIC BATCH and SIMATIC WinCC products
require the purchase of the relevant license or licenses.
1)
Units are the number of subsystems that can be operated with this license.
Current versions:
SIMATIC BATCH for WinCC V7.1 SP1 (only runs on
Windows XP und Windows 2003 Server operating systems)
- WinCC V7.0 SP3
- SIMATIC BATCH V7.1 SP1
Configuration
SIMATIC BATCH for WinCC
Benefits
SIMATIC BATCH for WinCC supports the user in the imple-
mentation of batch processes in accordance with ISA S88
Modular architecture with flexible scalability and optimal
adaptation to plant size and individual requirements,
especially with regard to the use of PLCs such as
SIMATIC S7-400/300, SIMATIC S5 and non-Siemens devices
High availability via redundant system configurations provides
protection against loss of batch data
Cross-subsystem recipes with significant simplification of
recipe management
Hierarchical recipes in accordance with ISA S88.01 for the
creation of recipes oriented toward process engineering
Saving, archiving and comprehensive reporting of batch data
Formula support
Validation in accordance with 21 CFR Part 11 is significantly
simplified by functions such as Audit Trail (change log),
versioning of recipes, recipe operations and formulas,
electronic signature and access protection.
Application
SIMATIC BATCH for WinCC has been designed for:
Batch processes in the WinCC environment in accordance
with ISA S88
Users of S7-300, S7-400, S5 or non-Siemens controllers
Users of STEP5/STEP7
Design
SIMATIC BATCH for WinCC ships with the following 3 software
components and licenses:
SIMATIC BATCH Server for 10 units
SIMATIC BATCH Recipe system (Floating License)
SIMATIC BATCH CC (Floating License)
The following SIMATIC BATCH options can be used to expand
or configure a plant or the relevant licenses can be purchased:
SIMATIC BATCH Recipe system (Floating License)
SIMATIC BATCH Planning (Floating License)
SIMATIC BATCH CC (Floating License)
SIMATIC BATCH Library
SIMATIC BATCH Hierarchical Recipe
SIMATIC BATCH Formula
SIMATIC BATCH Powerpacks (20, 40, 100, unlimited)
3rd-party PLCs
PROCESS BUS
S7-300/400
S5-135U
G_ST80_XX_00263
SIMATIC BATCH for WinCC
BASIC 10 Units
ST80_2013_EN_Kap04.book Seite 108 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
SIMATIC BATCH for WinCC
4/109
Siemens ST 80 / ST PC · 2013
Design (continued)
The following basic products and SIMATIC WinCC options can
be used to expand or configure a plant or the relevant licenses
can be purchased.
SIMATIC WinCC RT/RC (incl. Powerpacks)
SIMATIC WinCC/Server
SIMATIC WinCC/Redundancy
SIMATIC WinCC/Archives (incl. Powerpacks)
SIMATIC Logon
All previously listed software components including options of
SIMATIC BATCH and SIMATIC WinCC are supplied with the
product SIMATIC BATCH for WinCC. In addition, supplementary
components for configuring the interfaces between WinCC and
SIMATIC BATCH are included in the basic package.
The use and compatibility of WinCC and SIMATIC BATCH
is only guaranteed for the software versions that come with
SIMATIC BATCH for WinCC.
Function
The functions of SIMATIC BATCH for WinCC are based on the
SIMATIC BATCH range of products. SIMATIC BATCH for WinCC
includes the following licenses or functions:
SIMATIC BATCH Server for 10 units
SIMATIC BATCH CC (BATCH Control Center)
SIMATIC BATCH Recipe System (recipe editor)
It can be used to run a SIMATIC BATCH project with
10 subsystems on a single-user station or a client/server
combination (Batch Client and Batch Server).
The capacity of the Server Basic Packages with 10 units can be
expanded to 20, 40, 100 or unlimited units using SIMATIC
BATCH Powerpacks.
SIMATIC BATCH CC offers powerful functions for the following
tasks:
Reading in and updating the plant data of the basic
automation
Defining user privileges for all functions, for clients or
subsystems
Definition of material names and codes
Managing master recipes and starting the recipe editor
Management of libraries with recipe elements
(library operations)
Editing of formula categories and management of associated
formulas (parameter sets)
Creation of batches with master recipes
Starting of batch processing and controlling of batches
Monitoring and diagnostics of batch processing
Recording and archiving of recipes and batch data
Use of the "SIMATIC BATCH Hierarchical Recipe" license
permits the creation of hierarchical recipes in accordance with
ISA-88
The hierarchical recipe structure is mapped on the plant module
as follows:
Recipe procedure for controlling the process or the
production in a plant
Partial recipe procedure for controlling a process step in a
plant unit
Recipe operation/function to implement the process
engineering task/function in a technical facility
SIMATIC BATCH Separation, Procedures and Formulas offers
powerful functions for the following tasks:
The flexibility achieved by recipes which are independent of
plant units can be increased even further if the procedure and
parameter sets (formulas) are separated from one another.
Various master recipes can be created by linking several
formulas using a recipe procedure. This enables central modifi-
cation of procedures. The formula structure is determined by the
formula category defined by the user.
Compatibility
In respect of compatibility, please note that only the SIMATIC
WinCC and SIMATIC BATCH versions included in the product
package are compatible with each other. Only predecessor
products of the product bundle SIMATIC BATCH for WinCC are
upward compatible, not single components of the product range
SIMATIC WinCC and SIMATIC BATCH.
Integration
A detailed description of how to integrate SIMATIC Batch in
WinCC appears in the interface description "SIMATIC BATCH
Configuration Guide".
Ordering data
Order No.
SIMATIC BATCH for WinCC 6ES7657-1SA17-0YA0
Software bundle for the creation
of recipes and control of batch pro-
cesses in accordance with ISA S88
based on SIMATIC BATCH.
• SIMATIC BATCH Server 10 units
• SIMATIC BATCH Recipe system
(Floating License)
• SIMATIC BATCH CC
(Floating License)
Formula 3
900 kg
95 °C
12 min
No
Yes
50 g
Master Recipe #2 Master Recipe #3Master Recipe #1
Formula 2
500 kg
80 °C
15 min
Yes
No
150 g
Formula 1
1 000 kg
90 °C
10 min
Yes
No
100 g
Quantity
Temperature
Time
Salt
Pepper
Sugar
G_PCS7_XX_00064
ST80_2013_EN_Kap04.book Seite 109 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
SIMATIC Information Server
4/110 Siemens ST 80 / ST PC · 2013
4
Overview
The Information Server is the reporting system for WinCC and
the Process Historian. Based on Microsoft Reporting Services,
the historical data (tags and alarms) are made available via a
web client.
The Information Server Client does not need a client installation.
Using a pure web client, it offers functionality for administration,
configuration, and visualization of reports. Add-ins for Microsoft
Office applications such as Word and Excel offer additional
ways to access the WinCC and Process Historian database.
Reports can be created automatically cyclically and sent by
email. The Information Server can be used on a WinCC station,
on a Process Historian, or independently.
The basic package contains licenses for three clients and one
data source. The available licenses are additive and refer to
simultaneous access to the client computer. Pre-created report,
such as for trends and alarms, are contained in the standard
package.
Benefits
Central, web-based report system as interface for all
corporate areas up to the management level.
Simple handling through use of standard tools such as
Microsoft Word and Excel
Provision of freely configurable reports via the web
Automatic sending of reports via email
Import of data from any number of WinCC applications
Transparent access to WinCC tag and alarm logs as well as
SIMATIC Process Historian data
Highlights:
Frequently used report templates for process values,
messages, and batches
Open reporting system for creating any number of new report
templates
Storage of configured (parameterized) report templates for
faster access
Report export in common document formats
Support of subscriptions for cyclic report generation including
email service
Creation and storage of role-based dashboards
Role management for Windows users; supports workgroups
and Active Directory; user rights can be assigned for specific
projects
Generation of reports and inserting as graphics in Microsoft
Office Word documents
Creation of Microsoft Excel reports for historical process
values and messages as well as storage of the Excel report
templates on the Information
Server Support for subscriptions to Excel report templates
Ordering data
Order No.
View in the Web browser
IS client
Process Historian and
information server (IS)
Add-ins for
Microsoft Word and Excel
G_PCS7_XX_00298
SIMATIC Information Server 2013
"Basic Package" 6AV6361-2AA01-3AA0
• Information server
• Information Server -
Client access (3)
• Information Server -
Datasource access (1)
SIMATIC Information Server
• 1 Client access 6AV6361-2BD01-3BB0
• 3 Client access 6AV6361-2BE01-3BB0
• 5 Client access 6AV6361-2BF01-3BB0
• 10 Client access 6AV6361-2BG01-3BB0
• 1 Datasource access 6AV6361-2CD01-3BB0
• 3 Datasource access 6AV6361-2CE01-3BB0
ST80_2013_EN_Kap04.book Seite 110 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
SIMATIC Logon
4/111
Siemens ST 80 / ST PC · 2013
Overview
SIMATIC Logon (SL) for WinCC is a software option package
supporting the central administration of all WinCC users on a
plant-wide basis. The central user management with SL uses
the Windows mechanisms and is to be installed on all partici-
pating WinCC stations. The user management actions such as
logging in and out are automatically supplied in the audit trail
of WinCC/Audit and WinCC/ChangeControl by SL.
The WinCC/Audit or WinCC/ChangeControl and
SIMATIC Logon options support users in respect of plant
validation and meet the requirements of FDA CFR 21 Part 11.
A declaration of conformity (White Paper) offers proof of this.
Benefits
Central, system-wide user management
Conforms with the requirements of the Food and Drug Admin-
istration (FDA) for the pharmaceuticals and food processing
industry
Design
The SIMATIC Logon Service can be used for the central user
management of a number of WinCC stations. Operation in a
Windows Workgroup or even in a domain is possible.
Function
SIMATIC Logon
Users receive a unique user ID, user name and password.
This information is stored encrypted at a central point
(for SIMATIC Logon in the Windows user management).
Functions such as changing the password, automatic logoff
after a predefined time and lockout after several incorrect entries
of a password ensure maximum security of operation.
In the case of the SIMATIC Logon, user administration is
integrated into the security system and user administration of
MS Windows.
To meet in particular the Food and Drug Administration (FDA)
requirements for the pharmaceuticals and food processing
industry, all user and administrator actions, such as log in, log
out, password changes, incorrect password inputs, and creating
and deleting users, are recorded with timestamp in a secure
database or are available in the audit trail of WinCC/Change
Control or WinCC/Audit.
In addition, SIMATIC Logon allows setting up new users online,
plant-wide and across applications, or blocking existing users.
SIMATIC Logon also supports electronic signature.
Ordering data
Order No.
1)
SIMATIC Logon included in scope of supply of WinCC
More information
Information on FDA can be found in a White Paper:
Declaration of conformity of SIMATIC WinCC for FDA21 CFR
Part 11.
http://www.siemens.com/automation/hmi/html_76/products/
software/wincc/fda01.htm
SIMATIC Logon V1.4 SP1 6ES7658-7BX41-2YA0
Central user management for
WinCC V6.2 and WinCC V7.0
Runtime license for an operator
station
1)
SIMATIC Logon V1.5 upgrade 6ES7658-7BX51-0YA0
Single License, 7 languages
(De, En, Fr, Es, Jap, Chin)
ST80_2013_EN_Kap04.book Seite 111 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
SIMATIC Maintenance Station
4/112 Siemens ST 80 / ST PC · 2013
4
Overview
System-integrated plant asset management system
Automatic generation of a maintenance view in WinCC from
the STEP 7 hardware configuration
Plant-wide visualization of all automation components from the
management level to the field level in ready linked, hierarchi-
cally arranged WinCC displays
Mapping of central and distributed SIMATIC S7 components,
PROFIBUS and PROFINET networks as well as associated
bus nodes
Ethernet network components and industrial PCs can be
integrated through SIMATIC NET SNMP OPC Server
Display of device status with group status generation in
overview and detail displays
The device statuses "Maintenance required" and "Mainte-
nance request" are supported for status-based maintenance
Provision of uniform faceplates showing detailed information
for all components displayed
Display of the device identification data
(electronic rating plate)
Integrated display of the status of the request
Benefits
Reducing down times:
- Problems in the plant are detected sooner due to the uniform
presentation and clear overview of all information that is
important for maintenance.
Avoiding downtimes:
- Support of condition-based maintenance.
Reduced maintenance costs:
- Optimization of the flow of information between production
and maintenance by submitting maintenance requests and
presenting the status of requests.
Transparency and traceability:
- All procedures are based on messages and can therefore be
archived and traced.
- A comprehensive database is generated that can be
analyzed with WinCC functions or external tools.
Scalability:
- Support of WinCC single-user stations and client/server
configurations.
- The SIMATIC Maintenance Station can be added to an
existing WinCC project.
• Consistency:
- The maintenance view is generated from the control project
and is consistent with it.
Flexibility in selection of devices:
- Use of the PROFIBUS and PROFINET standards for device
interfacing.
- An additional proxy concept allows devices to be displayed
that are not included in the STEP 7 hardware configuration or
that do not support the standard diagnostics of PROFIBUS/
PROFINET.
Application
The SIMATIC Maintenance Station is a tool for the diagnosis and
maintenance of machines and plants. This is an option package
for STEP 7 V5.4 and WinCC V6.2 or V7.0 that generates a WinCC
maintenance view for a STEP 7 project/multiproject.
Design
The SIMATIC Maintenance Station is available in various
different packages:
Basic package:
Contains all the tools needed to configure a Maintenance
Station and a license for the display of 100 devices.
• Powerpacks:
For larger quantities, powerpacks are available with licenses
for 100, 500 or 1000 devices. These can be added to the
existing licenses and can be combined as required.
In this context, devices can be:
AS systems
Distributed devices (PROFIBUS / PROFINET)
•PCs
Network components
Asset proxies
Requirements for configuring a
SIMATIC Maintenance Station
STEP 7 license (V5.4 upwards)
WinCC RC license (V7.0 upwards)
The SIMATIC NET licenses required for the plant configuration
Requirements for operation of a
SIMATIC Maintenance Station
The WinCC licenses (V7.0 upwards) complying with the plant
configuration
ST80_2013_EN_Kap04.book Seite 112 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
SIMATIC Maintenance Station
4/113
Siemens ST 80 / ST PC · 2013
Function
Hierarchic visualization of plant components in WinCC
Generation of a WinCC picture tree for hierarchic display of
the plant components.
Automatic creation and linking of displays, equipment
symbols, status indicators, faceplates and the required
variables.
Presentation of the detailed data in faceplates with selectable
views.
Easy navigation in the plant using the WinCC Picture Tree
Manager.
Generated pictures can be enhanced using the
WinCC Graphic Designer.
Switchover between a WinCC SCADA project and the picture
tree of the SIMATIC Maintenance Station can be configured
using standard WinCC functions.
Display of the current status of the plant and its components
Clearly understandable status displays through the use of
uniform symbols.
Display of no-fault status, fault, maintenance requirement and
maintenance request.
Display of status of request for submitted repair requests.
Display of order status.
Display of the alarm status of the components.
Display of the identification data of the plant components
Display of the identification data available for a device in the
faceplate for the device.
Automatic loading of the data available in the configuration
into the maintenance station.
Reading of the "Identification & Maintenance functions
(I&M
1)
)" in accordance with the PROFIBUS International
specification.
•Export
2)
of I&M data for all devices in the form of an XML file.
Displaying alarms
Loading of system error messages from STEP 7.
STEP 7 provides the messages in 5 languages
3)
,
translation into additional languages is possible in STEP 7.
Display of the most recent message in a message line.
Presentation of the active/archived messages of the selected
device in the faceplate.
Calling the STEP 7 hardware configuration
The STEP 7 hardware configuration can be opened for a
selected device using a button in the faceplate. STEP 7 and
the project must be installed on the maintenance station for
this purpose.
1)
The Maintenance Station 2007 supports reading of I&M data for
PROFIBUS devices with C1 channel access.
2)
The I&M data loaded from the configuration are exported.
3)
For Siemens components that are included in the STEP 7 hardware
catalog.
In the case of components that are integrated in STEP 7 using GSD files,
the GSD files must support the relevant languages.
Technical specifications
Hardware requirements
Software requirements
System Clock fre-
quency Main
memory Free
hard disk
space
Engineering station 2.8 GHz 1 GB 15 GB
Maintenance Station Stand-alone /
WinCC-Station "Single-user
Workstation"
2.8 GHz 1 GB 15 GB
Maintenance Station Server /
WinCC Server 2.8 GHz 1 GB 15 GB
Maintenance Station Client /
WinCC Client 2.8 GHz 512 MB 3 GB
System Operating system
Engineering station "ES" Windows XP Professional SP3
Windows Server 2003 (R2) SP2
Windows Server 2008 R2 SP1
MS Windows 7 SP1.
Supported versions:
Ultimate and Professional
Maintenance Station Stand-alone /
WinCC-Station "Single-user Worksta-
tion"
Windows XP Professional SP3
Windows Server 2003 (R2) SP2
Windows Server 2008 R2 SP1
MS Windows 7 SP1.
Supported versions:
Ultimate and Professional
ES with Maintenance Station
Stand-alone Windows XP Professional SP3
Windows Server 2003 (R2) SP2
Windows Server 2008 R2 SP1
Windows 7 SP1.
Supported versions:
Ultimate and Professional
Maintenance Station Server /
WinCC Server Windows Server 2003 (R2) SP2
Windows Server 2008 SP2
Windows Server 2008 R2 SP1
Maintenance Station Client /
WinCC Client Windows XP Professional SP3
Windows Server 2003 (R2) SP2
Windows Server 2008 SP2
Windows Server 2008 R2 SP1
Windows 7 SP1.
Supported versions:
Ultimate and Professional
ST80_2013_EN_Kap04.book Seite 113 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
SIMATIC Maintenance Station
4/114 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
4
Requirements for the integration of devices
1)
With S7-300, PROFIBUS/PROFINET systems are supported if they are
connected to the internal CPU interfaces
Type Integration Comment
SIMATIC S7 controllers / I/O
• S7-300
1)
Yes
• S7-400 Yes
•WinAC Yes
Distributed devices
ET 200 Yes PROFIBUS DP and
PROFINET IO
according to STEP 7
hardware catalog
PROFIBUS standard slaves Yes Integration using a
GSD file
PROFINET standard devices Yes Integration using a
GSD file
Network components
Ethernet network components Yes SIMATIC NET SNMP
OPC Server and MIB
also required
PROFINET network components Yes
PROFIBUS diagnostic repeater Yes
Personal Computer
PC/Industrial PC Yes SIMATIC NET SNMP
OPC Server also
required
Drives
Drives with PROFIBUS connection Yes For integrating
devices designed
to the PROFIDRIVE
profile, Drive ES
SIMATIC (V5.4 SP1
or higher) is required
Drives with PROFINET connection Yes For integrating
devices designed
to the PROFIDRIVE
profile, Drive ES
SIMATIC (V5.4 SP1
or higher) is required
Accessory devices
Devices not configured in STEP 7
Hardware Config Yes Integrated via
function block
(asset proxy)
Ordering data
Order No.
SIMATIC Maintenance Station
2009
Can be used with STEP 7 V5.4 or
higher and WinCC V7
• Basic package
with engineering software
(Floating License) and Runtime
License for 100 devices
6ES7840-0WD01-0YA0
• Powerpack 100
Runtime License
for 100 additional devices
6ES7840-0WD11-0YD0
• Powerpack 500
Runtime License
for 500 additional devices
6ES7840-0WD21-0YD0
• Powerpack 1000
Runtime License
for 1000 additional devices
6ES7840-0WD31-0YD0
• Basic demo package 2009 6ES7840-0WD01-0YA7
• Upgrade from
SIMATIC Maintenance Station
2007 to SIMATIC Maintenance
Station 2009
6ES7840-0WD01-0YE0
ST80_2013_EN_Kap04.book Seite 114 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
SIMATIC Process Historian
4/115
Siemens ST 80 / ST PC · 2013
Overview
The Process Historian is a high-performance tong-term
archiving server solution that stores WinCC process values and
messages in a central database. The system offers full
scalability for performance and scope: It records and saves data
from one or several WinCC and PCS 7 projects. The number of
connected single stations, servers, or redundant server pairs is
unrestricted. SIMATIC Process Historian is designed for use
throughout your plant, below the corporate management level
(ERP, MES).
Process Historian is the basis for the Information Server
reporting system, which accesses the central Process Historian
database and ensures clear, user-friendly data visualization on
WinCC stations and office PCs.
The central Process Historian database provides access to real-
time data throughout the plant. This data is the key to sustainable
plant optimization.
Because this is a completely integratable archive system,
the engineering can also be performed without additional effort.
SIMATIC Process Historian uses the integrated relational
database Microsoft® SQL Server.
No complex reconfiguration is needed because the archive
system is integrated in WinCC. Time or event-driven archiving of
selected process values or messages in the WinCC long-term
archive is possible.
Benefits
Fully integrated long-term archive solution for large volumes
of data
Central, plant-wide long-term archive as company-wide
information hub
Process data and messages can be archived from any
number of lower-level WinCC systems
Plant expansions without interrupting the production process
High availability in redundant mode
High degree of security due to integrated backup system
Database for analyses with the goal of optimizing the plant
and thus the productivity
Function
Real-time data storage of the WinCC archive data (process
values and messages) from any number of WinCC stations
Visualization of the archive data on WinCC clients or WinCC
single stations either directly or using the SIMATIC Information
Server. Process Historian configuration tool for fast, simple
engineering
The redundant Process Historian is based on Microsoft SQL
Server Mirroring (third system for monitoring the availability of
redundancy).
The database and segmenting are set up in the initial
configuration.
For archiving to the PH, the PH Ready component is installed
on the WinCC server
The PH automatically detects all connected WinCC server
projects (via the PH Ready component)
The "Process Historian Management" dashboard for
diagnostics, displaying data sources, changing the database
segmentation
Ordering data
Order No.
OS clients
Automation
systems
- OS server
- Batch server
Process Historian
Information server
OS single
station
Terminal bus
Plant bus
Project A Project B
G_PCS7_XX_00297
SIMATIC Process Historian Server
2013 Single License 6AV6361-1AA01-3AA0
SIMATIC Process Historian Server
2013 Single License
(Redundancy Complete)
6AV6361-1BA01-3AA0
• 2x Process Historian Server
• 2x Process Historian Server -
Redundancy
SIMATIC Process Historian 2013
Single License Redundancy 6AV6361-1CA01-3AA0
Upgrades
Upgrade from CAS
(Central Archive Server)
V7.0 SP3 to
Process Historian 2013
6AV6361-1AA01-3AE0
ST80_2013_EN_Kap04.book Seite 115 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/Calendar Scheduler
4/116 Siemens ST 80 / ST PC · 2013
4
Overview
Option for SIMATIC WinCC for managing events in a calendar.
Setting WinCC variables or starting global scripts at defined
times.
A license is only necessary on the server
(or single user system).
Benefits
Simple operation, configuration and planning of events thanks
to handling in the style of Microsoft Office Calendar
Simple configuration of the actions by parameterization
(execution of WinCC scripts or writing of WinCC tags at certain
times)
Configuration of recurring events taking account of configu-
rable public holidays, vacation periods, and maintenance
periods
Secure operation of the plant taking account of different
authentication levels
Clear representation of events at runtime by means of
Calendar Runtime Control
Flexible use in all typical WinCC plant configurations,
client/server, redundant systems, WebNavigator
Function
With the WinCC Calendar Scheduler, events and their
associated actions can be configured in a user-friendly and
clear way in an editor in WinCC Explorer.
The events are represented in a calendar. The period repre-
sented can be freely selected. Recurring events can be defined
as serial events with any desired exceptions.
The events are displayed in a .Net control. The Calendar
Scheduler is easy and intuitive to operate and supports drag &
drop during configuration and runtime.
Ordering data
Order No.
WinCC/Calendar Scheduler
• for WinCC V7.2 6AV6372-1DC07-2AX0
• for WinCC V7.0 SP3 6AV6372-1DC07-0AX0
ST80_2013_EN_Kap04.book Seite 116 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/Central Archive Server (CAS)
4/117
Siemens ST 80 / ST PC · 2013
Overview
Central data management, reliable, high-performance archiving
and central backup mechanisms form the basis of a Process
Historian solution: Integration in the SCADA world, data inter-
faces for access to archived data and analysis functions are the
component parts.
The option CAS was designed for this purpose and is used to
export the archived data of all servers in the system to a
computer and manage it. Integration of CAS in the WinCC world
means that the data remains available for the WinCC clients as
well as for the WinCC standard interfaces.
WinCC/CAS contains all licenses for the central archive server
including 1500 archive tags. The number of archive tags can be
increased to 120000 using Powerpacks or further WinCC
archives.
Benefits
Central data management of all archived alarms and process
values
Integrated back-up system for the archive data
Transparent access to the data from all WinCC clients and
over the open interfaces
Integrated Web viewer for analyzing data
Function
Both the process value archive and alarm log are created on the
separate WinCC servers and transferred to CAS when individual
database segments have been closed.
With "Store&Forward", when the network is interrupted between
the WinCC server and CAS, data will be reliably transferred as
soon as the network is operating again.
Data access is transparent for display and analysis and is still
possible through the standard WinCC clients. For the clients, it
is of no consequence whether the data are on the WinCC server
or already on CAS. Data saved in CAS can also be viewed using
the Web viewer included in the package.
The data of the distributed WinCC system can also be accessed
through the familiar interfaces (OPC DA, OPC A&E, OPC HDA
and Ole-DB) with the help of the Connectivity Pack or the
Connectivity Station. In this manner, the data saved in CAS can
be efficiently transferred to higher-level systems or used for the
purposes of analysis.
Ordering data
Order No.
Note:
Standard Archive Powerpacks (see WinCC ordering data) can
also be used for WinCC/Central Archive Server (CAS)
WinCC V7.2 is not supported. The successor product is the
option Process Historian for V7.2.
WinCC/CAS V7.0 SP3
basic packages
• WinCC/CAS V7.0 SP3 6AV6371-1DQ17-0XX0
• WinCC/CAS V7.0 SP3 ASIA 6AV6371-1DQ17-0XV0
WinCC/CAS upgrade
• V6.2 to V7.0 SP3 6AV6371-1DQ17-0XX3
V6.2 ASIA to V7.0 SP3 ASIA 6AV6371-1DQ17-0XV3
WinCC/CAS V6.2 SP3
basic packages
• WinCC/CAS V6.2 SP3 6AV6371-1DQ16-2XX0
• WinCC/CAS V6.2 SP3 ASIA 6AV6371-1DQ16-2XV0
ST80_2013_EN_Kap04.book Seite 117 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/ChangeControl & WinCC/Audit
4/118 Siemens ST 80 / ST PC · 2013
4
Overview
WinCC/ChangeControl is used to trace engineering
changes in a tamper-proof long-term audit trail database,
called the audit trail for short. All changes are automatically
entered in the engineering system in the audit trail. This
enables all the changes to be traced that have been made, to
deduce the causes and minimize downtimes on the system.
To begin tracing at a defined project status, a project version
definition is provided that contains all data and files of a
WinCC project version. The project version definition naturally
provides the ability to reactivate earlier project versions.
Document management is also provided, which manages and
archives intermediate status for system graphics, reports or
user files and stores change information of the user. An audit
viewer with helpful filter functions can be used for quickly and
simply evaluating the audit trail, exporting it to an Excel sheet
or printing it out.
WinCC/Audit Includes the full functionality of
WinCC/ChangeControl and is also used for tracing all
operations. All operations are automatically recorded in the
audit trail at RT.
Licensing : To configure which change information
from the project should be recorded in the audit trail, the
WinCC/ChangeControl RC or WinCC/Audit RC package is
required. "RC" stands for Runtime and Configuration. It is
required on the station that is to be configured and also
includes an RT license. For recording an audit trail, one
WinCC/Audit RT license is required per WinCC station
(Client/Server).
The WinCC/Audit or WinCC/ChangeControl and
SIMATIC Logon options support users in respect of plant
validation and meet the requirements of FDA CFR 21 Part 11.
A declaration of conformity (White Paper) offers proof of this.
Benefits
Quick and easy traceability configuration
Gap-free and automated recording of engineering changes
and operator actions in an audit trail
Reduction in plant downtimes thanks to fast analysis of the
gap-free recorded audit trail information
Logging of defined WinCC project status with all database
information and files of the application
Gap-free documentation of the project version definition
procedures with version number, user and comments
Complete tracing support by WinCC single and multi-station
systems, single and multi-project solutions, Client/Server
architecture
Extensive reduction in engineering outlay in order to meet the
requirements of FDA 21 CFR Part11 & EU 178/2002
Compliance with the requirements of the Food and Drug
Administration (FDA) for the pharmaceutical and food
industries.
Design
WinCC/ChangeControl and WinCC/Audit consist of five compo-
nents:
The audit editor for configuration the audit trail content
The project version definition for logging WinCC projects
Document management for automatic archiving and
versioning of WinCC plant mimics, scripts, reports, and
project-specific documents, and the recording of the
associated change information
The audit viewer for visualizing, exporting and printing
WinCC and WinCC flexible audit trails. The viewer is available
as an executable program under Windows, as well as OCX
with WinCC Runtime.
The audit trail, which tracks all changes in respect of both
engineering and plant operation in a separate SQL database.
The audit trail can be set up as a central audit trail for a
number of projects or even just for a single project.
WinCC/ChangeControl and WinCC/Audit support both single-
user and multi-user systems, client/server architectures and
even the WinCC redundancy system. No redundant audit trail is
created however.
ST80_2013_EN_Kap04.book Seite 118 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/ChangeControl & WinCC/Audit
4/119
Siemens ST 80 / ST PC · 2013
Function
WinCC/ChangeControl
WinCC/ChangeControl is a functional subset of WinCC/Audit.
WinCC/ChangeControl is for tracing engineering changes in the
engineering phase or in online operation. All change data is
recorded in an audit trail.
There are two types of engineering changes:
those that change the WinCC database or are executed
through the WinCC Explorer, such as e.g. changes to tag
management or creating a user group,
and those
limited to changing files, the so-called document adminis-
tration.
The document management manages system images, scripts
and log layouts and customer-specific documents and stores
respective intermediate versions as backups. All of these
documents or files are subject to a change process, i.e.
documents can be booked out for processing, booked in for
finalization and intermediate versions can be retrieved from
backup storage with a rollback function.
The project version definition as a component of
WinCC/ChangeControl archives WinCC projects and creates
reproducible project status or defined start-time points for
starting tracing. An audit trail is also provided with information on
who has created which project version or which version has
been reproduced or deleted.
Configuring the audit trail, the project version definition and the
document management is simple, quick and comfortable.
The audit trail data is visualized from WinCC, as well as from
WinCC flexible via the audit viewer, an executable program
under Windows. The data can also be evaluated with the audit
viewer OCX in Runtime by WinCC however. Users select the
desired view of the audit trail information via filters or selection
criteria and can export the data to an Excel file or print it on a
printer. Audit trail information is tamper-proof and can thus not
be modified or deleted. An export function can be used to swap
out the audit trail to an XML file or to archive it.
WinCC/Audit
WinCC/Audit has all of the functionality of WinCC/ChangeControl
and is also used for tracing user operations in RT operation.
Tracing can be used for determining who, when and what condi-
tions the machine has undergone. In addition to recording
operator activities, the audit trail also records the starting and
modifying of recipes or user logs. At specific objects or events,
such as function buttons or sliders, the user can also record
activities of an individual nature such as e.g., pressing a function
button, moving sliders and other actions with a so-called audit
entry function in the audit trail.
A WinCC/ChangeControl RC license or a WinCC/Audit RC
license is required for configuring the audit trail. One RT license
is required for each station (client/server) to be monitored. One
RC license always includes one RT license.
Ordering data
Order No.
More information
Information about FDA can be found in a White Paper:
Declaration of conformity of SIMATIC WinCC to FDA21 CFR
Part 11.
http://www.siemens.com/automation/hmi/html_76/products/
software/wincc/fda01.htm
WinCC/ChangeControl
For the configuration
of the audit trail incl. RT
• WinCC V7.0 SP3 6AV6371-1DV27-0AX0
• V6.2, for WinCC V6.2 and
WinCC V6.2 SP2/SP3 6AV6371-1DV26-2AX0
WinCC/Audit RC
For the configuration of the audit
trail incl. RT
• WinCC V7.0 SP3 6AV6371-1DV17-0AX0
• V6.2, for WinCC V6.2 and
WinCC V6.2 SP2/SP3 6AV6371-1DV16-2AX0
WinCC/Audit RT
Creation of audit trails in RT
• WinCC V7.0 SP3 6AV6371-1DV07-0AX0
• V6.2, for WinCC V6.2 and
WinCC V6.2 SP2/SP3 6AV6371-1DV06-2AX0
Upgrades
V6.x to V7.0
• for WinCC/Audit RT 6AV6371-1DV07-0BX4
• for WinCC/Audit RC or
WinCC/ChangeControl 6AV6371-1DV17-0BX4
V6.x to V6.2
• for WinCC/Audit RC and
WinCC/Audit RT 6AV6371-1DV06-2AX3
ST80_2013_EN_Kap04.book Seite 119 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/Connectivity Pack &
WinCC/Connectivity Station
4/120 Siemens ST 80 / ST PC · 2013
4
Overview
Cross-vendor communication in the automation sector has
always been of primary importance for WinCC. This is even more
true for the release of preprocessed production data for higher-
level information systems (e.g., MES = Management Execution
System, ERP = Enterprise Resource Planning or Office
packages = MS Excel, MS Access etc.). WinCC features
integrated OPC Data Access and OPC XML DA servers for
access to all online values in the system and makes open inter-
faces available for access to historical WinCC data.
The Connectivity Pack includes OPC XML DA 1.00, OPC HDA
1.20 (Historical Data Access), OPC A&E 1.10 (Alarm & Events)
and a WinCC OLE-DB interface which even allows remote
computers without WinCC to access WinCC archive and
alarm data.
The function of the OPC servers (XML DA, HDA and A&E) is
assured by the WinCC/Connectivity Pack. In order to access
data in the database via WinCC OLE-DB/OLE-DB, you will
also need a license for the WinCC/Connectivity Pack.
A Connectivity Pack license is required for every
WinCC system to be accessed.
If the Connectivity Station is used, an additional Connectivity
Pack license does not have to be installed on the WinCC
systems that are accessed. The Connectivity Station functions
autonomously and does not require a WinCC installation on
the computer.
For versions below V7.0
Access to WinCC archive and alarm data from a computer
without installed WinCC basic system license or WinCC option
via the interfaces of the Connectivity Pack or Connectivity
Station requires a WinCC/Client Access license on the client
side (see also "WinCC/Client Access License").
Connectivity Station Option for WinCC V6.2 and higher
Benefits
Access to variables, historical WinCC data, alarm data and
user archives from any computer
Options for analyzing and evaluating process data with
specialist tools or user-defined applications
(e.g., via VisualBasic)
Online data access
to variables
Online data access
to historical data
Database access through
3rd party application
Online messages
forward/acknowledge
OPC DA
OPC XML DA
OPC UA DA
OPC A&E OPC HDA
OPC UA HDA WinCC OLE-DB
MESMES VB (.NET),
VB Script, VBA
ERP
SIMATIC WinCC
WinCC/ConnectivityPack
MS SQL Server
G_ST80_XX_00066
ST80_2013_EN_Kap04.book Seite 120 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/Connectivity Pack &
WinCC/Connectivity Station
4/121
Siemens ST 80 / ST PC · 2013
Function
As an OPC HDA server, WinCC makes historical data from the
WinCC archive system available to other applications. An OPC
HDA client (e.g. a reporting tool) can define the time interval for
the required data by entering a start and end time. OPC HDA
servers also support the generation of a variety of aggregate
functions on the server itself (e.g. standard deviation, variance,
mean values, integral values, etc.), thereby helping to relieve the
load on the network, as only preprocessed data are transmitted.
OPC A&E servers are used to forward WinCC messages (along
with all associated process values) to any client at production or
enterprise control level. Filter mechanisms and subscriptions
ensure that only selected modified data are transmitted.
Acknowledgement is of course also supported.
The WinCC OPC XML DA server makes cross-platform commu-
nication between Windows and non-Windows systems possible,
even via the Internet. This enables read and write WinCC online
values (external and internal WinCC variables) to be exchanged
with non-Siemens systems.
WinCC OLE-DB makes standardized and user-friendly access to
WinCC archive data possible (MS SQL Server 2005). In exactly
the same way as access via the OPC HDA and OPC A&E inter-
faces, access via the WinCC OLE DB provider makes all WinCC
archive data available along with the associated process values
and message/user texts. The WinCC OLE-DB provider also
supports analysis functions such as minimum, maximum,
message hit list, etc.
The WinCC Connectivity Station was designed as a stand-alone
gateway to WinCC server data. It supports access to WinCC
server data over the OPC channels described as well as those
for process values (not alarms) over OLE DB . Access to WinCC
data is transparent, i.e. independent of which server of a
redundant pair is active or whether data have already been
transferred to the central archive server.
Connectivity Station
If no visualization is required at a station, any Windows computer
with access to WinCC via OPC and OLE-DB can be configured
via the Connectivity Station. This permits access to WinCC
stations with server packages from a central computer without
WinCC installation. The WinCC stations can be accessed via the
following interfaces:
OPC interfaces of the Connectivity Station
OLE DB interface of the Connectivity Pack
The two access variants are autonomous access options with
different ranges of functions.
OPC interfaces of the Connectivity Station
The Connectivity Station provides interfaces via which you can
access the following using an OPC-Client.
OPC-DA-Server: tags, e.g. process values
OPC-HDA-Server: archived process values
OPC-A&E-Server: alarms
Licensing
You require the "WinCC Connectivity Station" license in order to
utilize the OPC interfaces of the Connectivity Station on a
computer without WinCC installed.
If you only use the OPC interfaces of a WinCC installation, you
only need the "Connectivity Pack" license.
The following table shows the combinations:
The Connectivity Station is planned over NCM PC Manager or
SIMATIC Manager. In Version 7, the Connectivity Station does
not run as service.
Ordering data
Order No.
1)
Upgrades from V6.x to V7.x are included in the WinCC V7.x upgrades
New:
WinCC-independent
installation with
Connectivity Station
Standard
installation:
OPC with WinCC
OPC DA "WinCC Connectivity
Station" license No license required
OPC HDA "WinCC Connectivity
Station" license "WinCC Connectivity
Pack" license
OPC A&E "WinCC Connectivity
Station" license "WinCC Connectivity
Pack" license
OPC UA DA "WinCC OPC UA HDA
Connectivity Pack"
license
WinCC/Connectivity Pack &
WinCC/Connectivity Station
V7.2; for WinCC V7.2
Basic packages
• WinCC/Connectivity Pack V7.2
1)
6AV6371-1DR07-2AX0
WinCC/Connectivity Station V7.2
1)
6AV6371-1DR17-2AX0
V7.0; for WinCC V7.0,
WinCC V7.0 SP1/SP2/SP3 and
WinCC V7.0 SP1/SP2/SP3 ASIA
Basic packages
• WinCC/Connectivity Pack V7.0
1)
6AV6371-1DR07-0AX0
WinCC/Connectivity Station V7.0
1)
6AV6371-1DR17-0AX0
V6.2 SP3; for WinCC V6.2 SP3 and
WinCC V6.2 SP3 ASIA
Basic packages
• WinCC/Connectivity Pack V6.2
SP3 6AV6371-1DR06-2AX0
• WinCC/Connectivity Station V6.2
SP3 6AV6371-1DR16-2AX0
• WinCC/Connectivity Pack V6.2
SP3 ASIA 6AV6371-1DR06-2AV0
• WinCC/Connectivity Station V6.2
SP3 ASIA 6AV6371-1DR16-2AV0
Upgrade
1)
• WinCC/Connectivity Pack V6.x ->
V6.2 SP3 6AV6371-1DR06-2AX3
ST80_2013_EN_Kap04.book Seite 121 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/DataMonitor
4/122 Siemens ST 80 / ST PC · 2013
4
Overview
The WinCC/DataMonitor is a component of WinCC Plant
Intelligence and is used for displaying and evaluating current
process statuses and historical data on office PCs with
standard tools such as Microsoft Internet Explorer or Microsoft
Excel. The DataMonitor client is provided with current and
historic process data and alarms by a DataMonitor server.
All staff ranging from machine operators to corporate
managers can use the DataMonitor to obtain information.
DataMonitor is a suite of Internet-capable tools:
- Process Builder - Tool for simple visualization and
navigation with WinCC screens using WinCC Web Viewer
(WinC Viewer RT) in "view only" mode
- Excel Workbooks - Protocol tool that integrates WinCC
archives and online values into MS Excel and supports
online analysis
- Published Reports - Event- or time-driven execution of Excel
or PDF reports for the output of process data and analysis
results
- Web center - Individual configuration of Internet pages and
summary of information within a portal in terms of WinCC
applications
- Trends and alarms are preconfigured Web Center pages
DataMonitor does not require manual client installation
because it loads the required components from the
DataMonitor server
There is no installation required on the client for the
Webcenter, Trends and Alarms functions.
Licenses for simultaneous access by 1, 3, 10, 25 or
50 DataMonitor clients. Any combination of DataMonitor and
Web Navigator licenses can be used for an application.
Preconfigured Web Center pages permit ad hoc entry
Benefits
Information can be compiled online individually during
runtime via the Internet/intranet.
Efficiently monitor and analyze production lines.
- Display and evaluation of current process states and
historical data on remote office PCs with standard tools such
as Microsoft Internet Explorer or Excel.
- Easy access to production data via the intranet or Internet
- Quick ascertainment of the production situation
- Use of standard products
Easily collect and distribute information.
- Automated report creation
- No additional configuration effort through direct use of
images from the WinCC project
- No training required for standard products
- Easy exchange of configuration data
Substantiate decisions with reports.
- Evaluation via ready-made templates for special analyses of
the business processes (e.g. reports, statistics)
- Make bottlenecks transparent
- Individual views for user and situation
- Relative and absolute timeframe for information generation
View production status anywhere and anytime.
- Individual views of information in production
- View the process and system operation
- Historical data can be compiled online individually
Highlights
Access to the lower-level servers when installing the
DataMonitor server on a WinCC Client with separate project
(RT128 license)
Tag logging archive tags can be accessed by means of the
web center function without changing the WinCC configu-
ration system.
Installation of the DataMonitor web center function on a
WinCC file server
Dedicated Internet pages can be created for displaying data
with the Webcenter. For this purpose, the following tools which
can be integrated in the Internet sites are available.
- Bar diagram, pie chart, trend curve display
- Process value table and statistics functions for the process
values
- Alarms, hit list for alarms
- Message text display for individual message texts, message
display, selection list of created reports
- Links to internal and external pages
- Display of graphics in converted jpg format
- Display of the WinCC process images
The analyses can be made with relative or absolute time
specification. This enables comparisons of identical time
periods on different days.
Reports generated with Excel or the WinCC Report Designer
can be made available on the DataMonitor server or e-mailed
automatically to the relevant group of people based on time
intervals or triggered by events.
Connections can be established to WinCC Runtime, the
central archive server, and the swapped-out archives
ST80_2013_EN_Kap04.book Seite 122 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/DataMonitor
4/123
Siemens ST 80 / ST PC · 2013
Benefits (continued)
New in V7.2
DataMonitor
- In V7.2 or higher, the upgrade license is contained in the
corresponding WinCC version
- Supports Internet Explorer V 7.0, V8.0 and V9.0, including
tabbed browsing.
- Excel reports can be generated with Microsoft Excel
version 2003 / 2007 / 2010
Function
All tools are fully Internet-compatible and, therefore, support
access via any type of connection (LAN, GSM, radio, modem,
Internet, etc.).
All popular security mechanisms such as login/password,
firewalls, encryption, etc. are supported.
Users can combine the available tools at will. Licensing only
takes into account simultaneous access to one Web server.
For display purposes, screens from the WinCC project can be
used or special overview displays configured. Animations,
scripts, navigation and access rights remain valid.
The WinCC/DataMonitor has purely a display function.
Company-wide Excel reports, which contain historical and
current process values, can be stored centrally for general
access (reports, statistics). However, local queries to meet
individual requirements can be compiled and executed
online. Plot and tabular representation are supported for
archive data already swapped out.
Data can be automatically entered into created report
templates and distributed by e-mail or saved on the server.
The screens are displayed in the WinCC Web Viewer or in the
Internet Explorer in the view only mode of the Web Navigator.
Enhanced user management for the web center in order to
assign individual Internet pages and created reports to
specific user groups.
Integrating WinCC process screens on Internet pages without
installation download
A search function facilitates the management of connections
to the WinCC Server.
Swapped out archives can be connected and evaluated in the
DataMonitor Web center. Expansion of the display area in the
Web center (Menu Hide function)
Excel reports created offline can be loaded onto the
DataMonitor server and are thus made available to selected
user groups or for automatic distribution.
Pre-made elements make the assembly of individual web
pages easier for evaluating information.
Individual information compilation on one or more Internet
pages with the option of branching to other detail pages.
Pre-made Internet pages for trend and alarm display enable
an ad-hoc entry to Internet data evaluation.
An higher-level navigation feature provides a common
framework for the various tools.
Ordering data
Order No.
WinCC/DataMonitor V7.2 for
WinCC V7.2 and
WinCC V7.2 ASIA
• 1 client license 6AV6371-1DN07-2LX0
• 3 client licenses 6AV6371-1DN07-2AX0
• 10 client licenses 6AV6371-1DN07-2BX0
• 25 client licenses 6AV6371-1DN07-2CX0
• 50 client licenses 6AV6371-1DN07-2DX0
WinCC/DataMonitor
Powerpacks V7.0
• From 1 to 3 clients 6AV6371-1DN07-2LA0
• From 3 to 10 clients 6AV6371-1DN07-2AB0
• From 10 to 25 clients 6AV6371-1DN07-2BC0
• From 25 to 50 clients 6AV6371-1DN07-2CD0
WinCC/DataMonitor V7.0 for
WinCC V7.0, WinCC V7.0 SP3 and
WinCC V7.0 SP3 ASIA
• 1 client license 6AV6371-1DN07-0LX0
• 3 client licenses 6AV6371-1DN07-0AX0
• 10 client licenses 6AV6371-1DN07-0BX0
• 25 client licenses 6AV6371-1DN07-0CX0
• 50 client licenses 6AV6371-1DN07-0DX0
WinCC/DataMonitor
Powerpacks V7.0
• From 1 to 3 clients 6AV6371-1DN07-0LA0
• From 3 to 10 clients 6AV6371-1DN07-0AB0
• From 10 to 25 clients 6AV6371-1DN07-0BC0
• From 25 to 50 clients 6AV6371-1DN07-0CD0
WinCC/DataMonitor, Upgrade
from V6.0 to V7.0 6AV6371-1DN07-0XX4
from V6.2 to V7.0 6AV6371-1DN07-0XX3
• from V6.x to V6.2 SP3 6AV6371-1DN06-2XX3
• from V6.x ASIA to V6.2 SP3 ASIA 6AV6371-1DN06-2XV3
WinCC/DataMonitor V6.2 SP3 for
WinCC V6.2 SP3
• 1 client license 6AV6371-1DN06-2LX0
• 3 client licenses 6AV6371-1DN06-2AX0
• 10 client licenses 6AV6371-1DN06-2BX0
• 25 client licenses 6AV6371-1DN06-2CX0
• 50 client licenses 6AV6371-1DN06-2DX0
WinCC/DataMonitor V6.2 SP3
ASIA for WinCC V6.2 SP3 ASIA
• 1 client license 6AV6371-1DN06-2LV0
• 3 client licenses 6AV6371-1DN06-2AV0
• 10 client licenses 6AV6371-1DN06-2BV0
• 25 client licenses 6AV6371-1DN06-2CV0
• 50 client licenses 6AV6371-1DN06-2DV0
WinCC/DataMonitor,
Powerpacks V6.2
• From 1 to 3 clients 6AV6371-1DN06-2LA0
• From 3 to 10 clients 6AV6371-1DN06-2AB0
• From 10 to 25 clients 6AV6371-1DN06-2BC0
• From 25 to 50 clients 6AV6371-1DN06-2CD0
ST80_2013_EN_Kap04.book Seite 123 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/DowntimeMonitor
4/124 Siemens ST 80 / ST PC · 2013
4
Overview
The entry point to SIMATIC Plant Intelligence can be through
options for the SIMATIC WinCC process visualization system.
The WinCC/DowntimeMonitor is a component of WinCC Plant
Intelligence and is used for monitoring the efficiency and perfor-
mance of individual machine modules, subsystems and
production lines. The combined elements to be monitored are
designated as equipment. Using the WinCC/DowntimeMonitor,
the machine data management software, standstill time can be
recorded and analyzed centrally in production. For individual
devices, machines or entire production lines, the specific
parameters can be determined this way. Integration into WinCC
ensures complete transparency of all machine and plant data as
a basis for optimizing the plant's productivity.
The process values are read directly from WinCC and are
connected with the respective analysis function.
The SIMATIC WinCC DowntimeMonitor can be installed on a
WinCC single station, WinCC Server or WinCC Client with
project (RT128 license), and consists of an Engineering Client
as well as a Runtime User interface.
All engineering operations are performed using a graphic
Engineering Client. The Engineering Client is called up from
the WinCC Explorer.
SIMATIC WinCC DowntimeMonitor provides ActiveX control
elements. These are used for displaying the determined
parameters and the progress of the various status over a
certain time period. These controls are integrated in WinCC
process images for presenting results.
The recorded data is stored in an online database set and can
be moved to an offline database set.
The basic package consists of the Engineering and Runtime
software and 5 licensed equipment units. Other licenses are
available for up to 25, up to 50, 100 and up to 200 equipment
units.
Benefits
Recording failure times, localizing causes and reasons for
failure times, and monitoring of equipment efficiency.
Weak-point analysis in production processes and recording of
undesirable process activities.
Basis for decision making based on performance indicators.
Identification of the events that lead to cost-intensive failures.
Entry point for an extended downtime analysis with upgrade
options in the MES software SIMATIC IT.
Identification of speed and quality losses.
Complete transparency for all machines as basis for
optimizing the plant's productivity. Faults and bottlenecks are
prevented to increase availability.
Derivation of specific parameters (KPI - Key Performance
Indicators).
Integration of respective display instruments (controls) in
WinCC process images.
Can be utilized for individual machines or even complete
production plants.
Distribution of evaluations to various people over the web.
Function
Creation of a time model by defining various time categories
as a basis for the KPI calculation for elements (equipment) to
be evaluated.
Creation of equipment, as central components for the evalu-
ation by dividing the system into individual groups.
Creation of a Reason Tree for detailed display of reasons for
downtimes.
Allocation of the system status in the controller to the time
categories and Reason Trees defined in the DowntimeMonitor.
Storing the system status for calculating and presenting Key
Performance Indicators.
The following pre-defined Key Performance Indicators are
available: Availability, change-over, cycle time, failure time
loss, duration, effective performance, maintenance, Mean
Time Between Assist (MTBA), Mean Time Between Failures
(MTBF), Mean Time To Assists (MTTA), Mean Time To Repair
(MTTR), failure time frequency, Overall Equipment Effec-
tiveness (OEE), performance rate, production duration, quality
rate, speed loss, Total Efficient Equipment Performance
(TEEP), utilization.
Integration of three new controls Gant View, KPI View, and
Table View in WinCC for the display of results for one or more
equipment units.
The WinCC DowntimeMonitor Gant View presents the
equipment status development within a certain time period.
The WinCC DowntimeMonitor KPI View shows the distribution
of failure times and the Key Performance Indicators in a trend,
bar, segmented bar charts or Pareto chart using historical
data.
The WinCC DowntimeMonitor Table View shows raw data for
failure times and analyzes it in the selected time period. The
user can utilize these control elements to enter, change,
distribute or combine and comment on failure times manually.
The controls can be displayed on intranet or Internet using the
option WinCC/Web Navigator.
ST80_2013_EN_Kap04.book Seite 124 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/DowntimeMonitor
4/125
Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
Note
WinCC V7.2 is not supported.
WinCC/DowntimeMonitor
V7.0 SP3
for WinCC V7.0 SP3 and
WinCC V7.0 SP3 ASIA
5 equipment units 6AV6372-1DB07-0BX0
25 equipment units 6AV6372-1DB07-0DX0
50 equipment units 6AV6372-1DB07-0FX0
• 100 equipment units 6AV6372-1DB07-0HX0
• 200 equipment units 6AV6372-1DB07-0KX0
WinCC/DowntimeMonitor
Powerpacks V7.0
From 5 to 25 equipment units 6AV6372-1DB07-0BD0
From 25 to 50 equipment units 6AV6372-1DB07-0DF0
• From 50 to 100 equipment units 6AV6372-1DB07-0FH0
• From 100 to 200 equipment units 6AV6372-1DB06-2HK0
WinCC/DowntimeMonitor upgrade
V1.x to V7.0 SP3 6AV6372-1DB07-0XX4
WinCC/DowntimeMonitor
V1.0 SP1
for WinCC V6.2 SP2 and
WinCC V6.2 SP2 ASIA
• 5 equipment units 6AV6372-1DB06-2BX0
• 25 equipment units 6AV6372-1DB06-2DX0
• 50 equipment units 6AV6372-1DB06-2FX0
• 100 equipment units 6AV6372-1DB06-2HX0
• 200 equipment units 6AV6372-1DB06-2KX0
WinCC/DowntimeMonitor
Powerpacks V1.0
• From 5 to 25 equipment units 6AV6372-1DB06-2BD0
• From 25 to 50 equipment units 6AV6372-1DB06-2DF0
• From 50 to 100 equipment units 6AV6372-1DB06-2FH0
• From 100 to 200 equipment units 6AV6372-1DB06-2HX0
ST80_2013_EN_Kap04.book Seite 125 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/Event Notifier
4/126 Siemens ST 80 / ST PC · 2013
4
Overview
Option for SIMATIC WinCC for notifying selected persons by
e-mail in specified time slots
Notification depends on events occurring in the WinCC Alarm
System.
Escalation levels, i.e. Group 2 is only notified when nobody
"on site" or from Group 1 has reacted within a specified time.
Final notification of all persons previously notified in
connection with the specific event about the reaction that has
taken place
A license is only necessary on the server (or single user system).
Benefits
Simple operation, configuration and planning of notifications
thanks to handling like the Microsoft Office Calendar
Easy configuration of the notifications including support of the
WinCC Runtime languages by connecting to the WinCC alarm
system
Configuration of recurring events taking account of configu-
rable public holidays, vacation periods, and maintenance
periods
Secure operation of the plant taking account of different
authentication levels
Clear display and intuitive operation at runtime by means of
Calendar Control
Flexible use in all typical WinCC plant configurations, single
station, client/server, redundant systems, WebNavigator
Function
The WinCC Event Notifier enables the following to be configured
in a clear and user-friendly manner via the Calendar Options
Editor in the WinCC Explorer:
The e-mail service for sending and receiving messages
The messages by selecting configured messages in the
WinCC Alarm System as well the setup and contents of the
message by selecting the message blocks
Contacts by selecting predefined persons from the WinCC
user administration.
In a calendar it is then possible to select the persons to be
notified within in the opened time slot from the existing contacts.
If several persons or groups of persons are set up for the same
time slot, escalation levels can be implemented by assigning
different escalation times (= dead time before notification). The
period represented by the calendar can be freely selected.
Recurring events can be defined as serial events with any
desired exceptions.
The calendar can also be integrated as .Net Control in WinCC
screens; the appearance of the calendar controls at runtime is
configurable. Via the calendar control, you can create time slots
during runtime with contacts who should be notified upon occur-
rence of the configured events in the WinCC Alarm System. In
addition, the calendar control allows the creation of new
contacts by means of selection from the WinCC user
management.
The Event Notifier is easy and intuitive to operate and supports
drag & drop during configuration and runtime.
Ordering data
Order No.
WinCC/Event Notifier
• for WinCC V7.2 6AV6372-1DD07-2AX0
• for WinCC V7.0 SP3 6AV6372-1DD07-0AX0
ST80_2013_EN_Kap04.book Seite 126 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/IndustrialDataBridge
4/127
Siemens ST 80 / ST PC · 2013
Overview
The WinCC/IndustrialDataBridge option uses standard inter-
faces in order to connect the automation world with the world
of IT and ensure two-way information flow. Typical examples of
such interfaces are OPC in the field of automation and SQL
database interfaces in the world of IT.
With the SIMATIC WinCC/IndustrialDataBridge, simple
configuration/parameterization of communication connec-
tions between various data sources and data destinations can
be created. The IndustrialDataBridge can be integrated into
WinCC and can also be used in stand-alone mode
(not in conjunction with WinCC).
For example, SIMATIC WinCC with its OPC DA server
interface is the data source and an external database is the
data destination.
- Highly flexible, thanks to support for various database
formats and standard interfaces
- Fast and secure thanks to configuration instead of
programming
In addition to access to WinCC variables, access to
messages, process values and user archive data
(in the WinCC database) is also supported.
WinCC/IndustrialDataBridge can be used as stand-alone
application with its standard interfaces.
Option from WinCC V6
For versions below V7.0
On a computer without a license for the WinCC basic
system or a WinCC option, which is to be accessed in
read/write mode by the option WinCC/IndustrialDataBridge,
a WinCC Client Access License is required
(see also "WinCC/Client Access License").
Benefits
Connecting the automation level with the IT world
Integration of systems from different manufacturers via a host
of standard interfaces (including OPC, OLE-DB, Office
formats)
Simple configuration with standard software without
programming and thus at low cost
High-performance data transfer between several systems
simultaneously
Design
The software comprises a configuration environment and a
runtime environment. The different data interfaces are integrated
via software modules. In each case, one module is required as
the data source and one module as the data destination. The
different modules can be combined in any way.
The connections between data source and data destination are
created in the configuration environment.
In the runtime environment, the IndustrialDataBridge establishes
the connection autonomously and transfers the data of the linked
variables.
Microsoft SQL Server
Online
Data Exchange
Online
Data Exchange
Online
Data Storage
Online
Data Reading Data Export
WinCC V7
WinCC Professional
SIMATIC NET OPC Server
OPC DA & OPC XML DA
Microsoft Office
MS Excel
File (csv)
Microsoft Office
MS Access
WinCC/IndustrialDataBridge
SIMATIC WinCC
OPC DA
WinCC User Archive
MS SQL Server
OLE-DB
(Alarm-, Tag logging)
G_ST80_XX_00067
My Oracle
My SQL
ST80_2013_EN_Kap04.book Seite 127 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/IndustrialDataBridge
4/128 Siemens ST 80 / ST PC · 2013
4
Function
IndustrialDataBridge establishes a link between the source
and destination interfaces and transfers data on the basis of a
change in value, once a configurable period of time has
elapsed or when a specific event occurs.
IndustrialDataBridge exchanges data between automation
systems from different vendors, e.g., via OPC. The connection
of OPC servers via IndustrialDataBridge enables communi-
cation between a variety of devices, data sources and data
destinations. The OPC international interface standard is the
key to open systems both now and in the future. Thanks to
IndustrialDataBridge, OPC data exchange can already be
supported.
WinCC supports access to variables, tag logging, alarm
logging and user archive data.
Storage of process data in Office formats such as Excel or
Access. Databases can also be integrated for the archiving of
larger aggregates.
One of the features of IndustrialDataBridge is a Send/Receive
interface supporting data transfer to SIMATIC S5/S7 stations
or other Send/Receive-compatible devices.
IndustrialDataBridge enables SCADA and control systems
from different vendors to be linked via the OPC interface.
Communication via RFC1006 or Send/Receive is also
supported.
SQL databases are available as data destinations for
production data acquisition. Data can be transferred from the
data source on an event-driven basis with the OPC module or
sent directly from the PLC with the Send/Receive module.
Cyclic data archiving can be implemented via the OPC Data
Access, WinAC ODK or Send/Receive data sources and the
SQL database data destinations. On the database side,
various transmission mechanisms are supported.
Individual control during runtime for each
IndustrialDataBridge connection
(start, stop, connect, and disconnect).
Integration of IndustrialDataBridge runtime control in
WinCC screens if IDB is installed on a WinCC station.
Independent CSV files are created if a configurable number of
entries is reached or the value of a WinCC tag changes.
Block transfer for databases through support for the operators
"<" and ">" in the Select instruction.
Available providers (data sources) can be connected to any
consumers (data destinations) (see table, below)
New functions in Version 7.2:
Faster configuration due to new configuration interface
OPC XML DA Provider / Consumer (data exchange via the
Internet using HTTP and SOAP)
Support for Asian languages (Simplified Chinese, Japanese)
Unicode support
Getting Started for data exchange between User Archive and
Microsoft Access
For installation in combination with the WebNavigator Server,
the IndustrialDataBridge can be controlled via the Internet
Interfaces:
The table below shows the possible data sources and destina-
tions
Ordering data
Order No.
Provider (data sources) Consumer (data destinations)
• MS Access 2003, 2007, 2010
• MS SQL server 2005, 2008,
2008 R2
• MySQL ODBC 3, 5, 5.1, 5.5
• Oracle 8i, 10g, 11g
• OPC Data Access 3.0,
OPC XML 1.0
• Send / Receive
• WinCC OLE DB V7.2
• WinCC User Archive V7.2
•CSV, TXT
MS Access 2003, 2007, 2010
MS SQL server
MySQL ODBC 3, 5, 5.1, 5.5
• Oracle 8i, 19g, 11g
•MS Excel
OPC Data Access Server (internal)
OPC Data Access 3.0,
OPC XML 1.0
Send / Receive
• WinCC User Archive V7.2
WinCC/IndustrialDataBridge
V7.2, option for WinCC V7.2
For data exchange with databases
and OPC servers; language
versions: German, English, Chinese
simplified, Japanese
• with 128 tags 6AV6371-1DX07-2AX0
• with 512 tags 6AV6371-1DX07-2BX0
• with 2048 tags 6AV6371-1DX07-2CX0
• with 10000 tags 6AV6371-1DX07-2DX0
V7.0 SP1, option for WinCC V7.0
SP3
For data exchange with databases
and OPC servers; language
versions: German/English
• with 128 tags 6AV6371-1DX07-0AX0
• with 512 tags 6AV6371-1DX07-0BX0
• with 2048 tags 6AV6371-1DX07-0CX0
• with 10000 tags 6AV6371-1DX07-0DX0
WinCC/IndustrialDataBridge
Powerpack V7.2
• from 128 to 512 tags 6AV6371-1DX07-2AB0
• from 512 to 2048 tags 6AV6371-1DX07-2BC0
• from 2048 to 10000 tags 6AV6371-1DX07-2CD0
WinCC/IndustrialDataBridge
Powerpack V7.0
• from 128 to 512 tags 6AV6371-1DX07-0AB0
• from 512 to 2048 tags 6AV6371-1DX07-0BC0
• from 2048 to 10000 tags 6AV6371-1DX07-0CD0
WinCC/IndustrialDataBridge
upgrade
from V7.0 to V7.2 6AV6371-1DX07-2XX3
• from V6.x to V7.2 6AV6371-1DX07-2XX4
• from V6.x to V7.0 SP3 6AV6371-1DX07-0XX4
WinCC/IndustrialDataBridge
V6.1, option for WinCC V6. 2
For data exchange with databases
and OPC servers; language
versions: English/German
• with 128 tags 6AV6371-1DX06-1AX0
• with 512 tags 6AV6371-1DX06-1BX0
• with 2048 tags 6AV6371-1DX06-1CX0
• with 10000 tags 6AV6371-1DX06-1DX0
WinCC/IndustrialDataBridge
Powerpack V6.1
• from 128 to 512 tags 6AV6371-1DX06-1AB0
• from 128 to 2048 tags 6AV6371-1DX06-1AC0
• from 128 to 10000 tags 6AV6371-1DX06-1AD0
• from 512 to 2048 tags 6AV6371-1DX06-1BC0
• from 512 to 10000 tags 6AV6371-1DX06-1BD0
• from 2048 to 10000 tags 6AV6371-1DX06-1CD0
ST80_2013_EN_Kap04.book Seite 128 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/IndustrialX
4/129
Siemens ST 80 / ST PC · 2013
Overview
WinCC/IndustrialX makes it easier to develop a solution for a
visualization task by allowing customized objects to be
standardized
A license must be installed on each development computer
(current version of Visual Basic must be installed on the devel-
opment computer)
Benefits
Easy creation using configuration wizards
Quick entry due to the use of standards: ActiveX technology,
creating with the aid of Visual Basic
Central creating and changing of object displays of the same
type (typing) saves time and money
Configuring of intelligent, sector-specific objects (graphic
illustration and logical processing) with know-how protection
Can be used in versatile ways: in WinCC screens and other
Windows applications (e.g. Internet Explorer, Excel)
Innovations of V7.0
Support of Visual Studio 2005 (.NET)
Application
IndustrialX controls create standardized presentations and allow
flexible customization to the requirements of a wide range of
applications, e.g. applications in the chemical, glass or paper
manufacturing industries.
Function
Configuring intelligent, industry-specific objects (graphic
illustration and logical processing) with know-how protection
Automatic object supply with WinCC data structures
(templates)
Creation of Web Navigator-compatible, customer-specific
ActiveX components with active process data supply
Integration into WinCC via structure names
Ordering data
Order No.
Note
For WinCC V7.2, the WinCC/IndustrialX option is part of the
WinCC/ODK option.
WinCC/IndustrialX
• V7.0; for WinCC V7.0 and V6.x 6AV6371-1EL17-0AX0
ST80_2013_EN_Kap04.book Seite 129 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/Open Development Kit (ODK)
4/130 Siemens ST 80 / ST PC · 2013
4
Overview
WinCC/ODK (Open Development Kit)
WinCC option for utilization of the exposed programming inter-
faces that can be used to access data and functions of the
WinCC configuration and WinCC runtime system
The interfaces are designed as "C-Application Programming
Interface" (C-API)
Scope of delivery:
- CD-ROM with examples
- Voucher for a one-day intensive workshop
Benefits
Individual system expansions via an open standard
programming language
Access to data and functions of the WinCC configuration and
runtime system
Development of your own applications and add-ons for the
WinCC basic system
New in V7.0
Support for Visual Studio 2005 (.NET)
New in V7.2
UNICODE support
Support for Visual Studio 2008, 2012
Function
The API functions are configuration and runtime functions, and
include:
MSRTCreateMsg: Creates a message
DMGetValue: Gets the value of a variable
PDLRTSetProp: Sets the object properties in a display
They can be used in the following places:
within WinCC, for example in global scripts or as part of C
actions in the Graphics Designer,
in Windows applications in the programming language C
(the current version of Microsoft Visual C++ is necessary as a
development environment for WinCC).
Ordering data
Order No.
WinCC/ODK
• V7.2; for WinCC V7.x 6AV6371-1CC07-2AX0
• V7.0; for WinCC V7.0 and V6.x 6AV6371-1CC07-0AX0
ST80_2013_EN_Kap04.book Seite 130 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/ProAgent
4/131
Siemens ST 80 / ST PC · 2013
Overview
Precise and rapid process fault diagnostics in plants and
machines for SIMATIC S7 and SIMATIC HMI
Standardized diagnostics concept for various
SIMATIC components
No further configuration for diagnostics functionality
Reduces PLC memory and processor usage
Note
For further details, see "SIMATIC ProAgent process diagnostics
software"
Ordering data
Order No.
3B 67  B ; ; B   
67(3
SIMATIC WinCC/ProAgent
• V7.2; for WinCC V7.2 6AV6371-1DG07-2AX0
• V7.0 SP3; for WinCC V7.0 SP3 6AV6371-1DG07-0AX0
SIMATIC WinCC/ProAgent
Upgrade
• to SIMATIC WinCC/ProAgent V7.2 6AV6371-1DG07-2AX3
• to SIMATIC WinCC/ProAgent V7.0
SP3 6AV6371-1DG07-0AX4
ST80_2013_EN_Kap04.book Seite 131 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/Redundancy
4/132 Siemens ST 80 / ST PC · 2013
4
Overview Option for SIMATIC WinCC, supporting the parallel operation
of two interfaced WinCC single-user systems or process data
servers for mutual monitoring
If one of the two server PCs or one of the two WinCC stations
fails, the second one will take over control of the entire system.
Once the failed server or station is restored to operation, the
content of all the message and process value archives are
copied to it.
One WinCC/Redundancy package is required for each
redundant pair of servers.
Benefits
Increased system availability with continuous data integrity
Automatic changeover of client in the event of failure of a
server or failure of the communication to a server
Continuous operator control and visualization thanks to
automatic client changeover to the intact server
Automatic updating of all archives in the background after
rectification of the fault
Function
Normally, two WinCC stations or process data servers run in
parallel. Each station has its own process connection and its
own data archives. WinCC/Redundancy ensures automatic
matching of system and user archive data.
If one of the two server computers or WinCC stations fails, the
second will take over the archiving of messages and process
data, thereby ensuring seamless data integrity. In client/server
mode, the clients are automatically switched from the failed
server to the redundant partner. This ensures continuous plant
visualization and operation on every operator station.
When the failed partner resumes operation, all process values,
messages and data archived during the fail period are automat-
ically matched with the partner. This process runs in the
background and does not affect plant continuity. Once this is
complete, two equivalent servers/stations will be available
again.
Communication with the SIMATIC S7 can also be configured with
redundancy (an H Series SIMATIC S7 is required) by plugging in
two communication modules and configuring two communi-
cation paths (S7-REDCONNECT software package). The use of
failsafe H Series SIMATIC S7 can, if required, further increase
availability at control level.
Ordering data
Order No.
~jj
z
~jj
j
wyvmpi|z
shu
wyvmpul{
G_ST80_XX_00082
~jj
z
~jj
j
wyvmpi|z
shu
wyvmpul{
G_ST80_XX_00083
~jj
z
~jj
j
wyvmpi|z
shu
wyvmpul{
G_ST80_XX_00084
SIMATIC WinCC/Redundancy
• Option for SIMATIC WinCC V7.2,
Runtime software, single license
for 2 installations
6AV6371-1CF07-2AX0
• Option for SIMATIC WinCC V7.0,
Runtime software, single license
for 2 installations
6AV6371-1CF07-0AX0
• Option for SIMATIC WinCC V6.2,
Single license for 2 installations 6AV6371-1CF06-2AX0
ST80_2013_EN_Kap04.book Seite 132 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/Server
4/133
Siemens ST 80 / ST PC · 2013
Overview
Option for SIMATIC WinCC, which permits the configuration of
a powerful client/server system
One of the following operating systems must be available to
install the option on the server: Windows Server 2003 (for V6)
or Windows Server 2003 R2 (for V6.2 / V7.0 / V7.2) or Windows
Server 2008 (for V7.0 with SP2 and higher or V7.2). When
using Windows XP Professional and Windows 7 SP1, no more
than 3 clients can be connected.
A number of coordinated HMI stations can be operated in a
single group with networked automation systems
Client/server solution:
- One server can supply up to 32 connected clients with
process and archive data, messages, images and reports
- Depending on the size of the plant, up to 12 servers
(or up to 18 in version 7.2 or higher) can be used.
- 32 clients (max. 12 or 18 redundant WinCC servers) possible
per system
Requirement:
Network connection (TCP/IP) between the server PC and the
connected clients.
1)
One license is required for each server.
1)
One of the following operating systems is installed on one WinCC server:
Windows Server 2003, Windows Server 2003 R2 or Windows Server 2008.
Max. 3 clients with Windows XP Professional and Windows 7 SP1.
Benefits
Plant-wide scalability from the single-user system to the
client/server solution
Significantly higher quantity framework, relieving the
individual servers and better performance due to distributing
the complete application or tasks over several servers
Low-cost configuration on the client is possible
(the minimum RC license is sufficient)
Application
In a complex plant, WinCC can also be configured as a
distributed system according to requirements:
Functional distribution (e.g. message servers, archive
servers, etc.) or
Distribution according to the physical plant structure
(e.g. body-in-white, paintshop, etc.)
Function
Each client can access more than one server at a time. Clients
can also be used for configuration on the server.
A configuration of WinCC clients as a central Web server - as a
distributed system if required - with an overview of all server
projects in the system is also possible.
For WinCC clients, only the smallest runtime license RT128 is
required. In order to also configure on WinCC clients, the
smallest complete license RC128 is required. Remote configu-
ration is possible if WinCC clients without their own project
(Uniclients) on the server project are configured. This makes it
possible to configure inexpensive operator and configuration
stations in a network.
Ordering data
Order No.
G_ST80_XX_00005
TERMINAL BUS TCP/IP
PROCESS BUS
WinCC Client WinCC Client WinCC Client
WinCC Server
SIMATIC WinCC/Server
• Option for SIMATIC WinCC V7.2,
Runtime software, single license 6AV6371-1CA07-2AX0
• Option for SIMATIC WinCC V7.0,
Runtime software, single license 6AV6371-1CA07-0AX0
• Option for SIMATIC WinCC V6.2,
Single license 6AV6371-1CA06-2AX0
ST80_2013_EN_Kap04.book Seite 133 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/TeleControl
4/134 Siemens ST 80 / ST PC · 2013
4
Overview
WinCC/TeleControl for WinCC V7.0 SP2 supports connection to
outlying stations (Remote Terminal Units = RTUs) via telecontrol
protocols.
Benefits
WinCC/TeleControl for WinCC V7.0 SP2 cannot only integrate
newly configured RTUs, it can also integrate units which already
exist in outlying areas by means of DNP3 or IEC 870-5-101/104
drivers.
For communication with the outstations, WinCC/TeleControl for
WinCC V7.0 SP2 uses the SINAUT ST7 and DNP3 protocols
(both via serial and TCP/IP communication connections) as well
as IEC 870-5-101 (serial) and IEC 870-5-104 (Ethernet TCP/IP).
The serial RTU link is possible via the following components,
which can be connected directly via WinCC (single station or
server):
SINAUT TIM communication modules
(SINAUT ST7 telecontrol protocol)
TCP/IP serial converter (telecontrol protocols DNP3, Modbus
(not released for WinCC TC), IEC 870-5-101)
Equipment from MOXA or Lantronix, for example, can be used
as TCP/IP serial converters.
By means of Ethernet TCP/IP, the RTUs can be connected
directly or via TCP/IP WAN routers to the SIMATIC WinCC system
bus (SINAUT ST7, DNP3, IEC 870-5-104 telecontrol protocols).
When using the SINAUT ST7 telecontrol protocol, the SINAUT
TIM communication module can be used in addition to the
TCP/IP WAN router or as an alternative.
Application
Telecontrol communication over the wide area network is largely
determined by the communication infrastructure which already
exists. Various transmission media such as dedicated line,
analog or digital telephone networks, wireless networks (GSM or
private), DSL or GPRS can also be combined with each other.
SINAUT ST7 telecontrol protocol
Detailed information for implementing telecontrol applications
with the SINAUT ST 7 telecontrol protocol via the Industry Mall.
IEC 870-5-101/-104 telecontrol protocols
Detailed information for implementing telecontrol applications
with the IEC 870-5-101/-104 telecontrol protocols via the
Industry Mall.
DNP3 telecontrol protocol
WinCC/TeleControl for WinCC V7.0 SP2 also supports the DNP3
telecontrol protocol. Widely distributed outstations (RTUs) can
be controlled and monitored with the DNP3 telecontrol protocol
via serial or Ethernet TCP/IP communication links by means of
the telecontrol center in SIMATIC WinCC. The control center
integrated with SIMATIC WinCC TeleControl into the SCADA
system is the master during telecontrol communication. The
slaves are represented by the outstations. SIMATIC S7-300/
S7-300F and S7-400/S7-400F/S7-400H/S7-400FH controllers
as well as third-party RTUs can be used as outstations.
Further hardware and software components round off the range
of products:
TIM communication modules
TCP/IP converters – serial and MD modem modules
GSM/GPRS components
TCP/IP routers and switches
SCALANCE S612 and S613 security modules
Dedicated-line accessories
Connecting cables and cables
Engineering package for configuration of DNP3 data objects,
stations, networks and connections as well as for diagnostics
In order to implement telecontrol networks, basic topologies
including point-to-point, multi-point, star and ring can be
configured using classic or TCP/IP-based media. These can be
combined flexibly independent from existing infrastructure.
Classic WAN media:
Dedicated line via modem, e.g. SINAUT MD2
Private wireless networks
Analog telephone network
Digital ISDN network
Mobile radio network GSM
TCP/IP-based WAN media:
Ethernet networks, e.g. SCALANCE X with fiber-optic cables
Industrial Wireless LAN with SCALANCE W
Public networks and the Internet using DSL and/or GPRS
Function
Special characteristics of DNP3 communication
Change-driven data transmission
- Change-driven transmission of process data between RTU
and control center
- Signaling of RTU, control center or connection failure
- Automatic data updating for all communication partners
involved following troubleshooting and following the startup
of the RTU or control center
Chronological processing of process data
- Time tagging of all data frames at the place of origin allows
process data to be archived by the process control system
in the correct chronological order
- The time of the DNP3 stations in the WAN can be synchro-
nized via SIMATIC WinCC (including summertime/wintertime
switchover)
Local data storage
- The TIM communication module can temporarily store
(for several hours or even days) message frames should the
connection or the communication partner fail
- Intermediate storage of message frames of lower priority in
the case of priority-controlled data transmission (with dial-up
networks or quantity-dependent data transmission costs)
Operating modes
The DNP3 telecontrol protocol supports the following operating
modes:
Polling
Polling with time slot procedure
Multi-master polling with time slot procedure
Spontaneous mode in dial-up networks
Spontaneous mode in the TCP/IP-based WAN
ST80_2013_EN_Kap04.book Seite 134 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/TeleControl
4/135
Siemens ST 80 / ST PC · 2013
Integration
Integration of WinCC/TeleControl for WinCC V7.0 SP2 into the
WinCC SCADA system offers particular advantages for the water
and waste water sectors, as well as oil and gas sectors,
especially in the case of the following types of plant:
Freshwater treatment and distribution
Wastewater treatment plants
Oil and gas pipelines and water pipes
Oil and gas drilling fields and the associated treatment plants
In these types of plant, remote outstations such as pumping
stations, valve stations or automated stations for wellheads must
be integrated.
Through the support of communication protocols for RTUs such
as SINAUT ST7, WinCC/TeleControl for WinCC V7.0 SP2
supports the following advanced communication concepts:
Reduction in the transferred data volume by means of event-
controlled communication mechanisms for alarm and
measured value information.
Time-synchronization of RTUs and correct time stamping of all
data in the RTU.
Tolerance of lower bandwidth, high latency or lack of reliability
of communication lines
Prevention of data loss due to communications failure through
data backup in the RTU
Support of communication media with serial interface
(dedicated lines, dial-up connections over analog telephone
lines and ISDN lines), various radio devices (standard, spread
spectrum modulation), microwave and GSM
Support for TCP/IP-based WANs (Wide Area Networks) such
as DSL, GPRS or Ethernet radio networks
Support for redundant communication connections
Expanded communication diagnostics functions for RTU
communication links
Remote programming of RTUs
Support for different communication topologies –
point-to-point, multidrop (multistation mode) and hierarchic
network structures
High quality server redundancy scheme without data loss in
the case of server failure
Through the support of communication protocols for RTUs such
as IEC 60870-5 and DNP3, SIMATIC TeleControl for WinCC V7.0
SP2 supports the following advanced communication concepts:
Reduction in the transferred data volume by means of event-
controlled communication mechanisms for alarm and
measured value information.
Time synchronization of RTUs and correct time stamping of all
data in the RTU.
Tolerance of lower bandwidth, high latency or lack of reliability
of communication lines
Prevention of data loss due to communications failure through
data backup in the RTU (not all non-Siemens RTUs support
this)
Support of communication media with serial interface
(dedicated lines, dial-up connections over analog telephone
lines and ISDN lines), various radio devices (standard, spread
spectrum modulation), microwave and GSM
Support for TCP/IP-based WANs (Wide Area Networks) such
as DSL, GPRS or Ethernet radio networks
Support for redundant communication connections
Expanded communication diagnostics functions for RTU
communication links
Remote programming of RTUs
Support for different communication topologies – Point-to-
point, multidrop (multistation mode) and hierarchic network
structures
High quality server redundancy scheme without data loss in
the case of server failure
Outstations/remote terminal units
WinCC/TeleControl for WinCC V7.0 SP2 supports the following
preferred outstations for local distributed automation:
Controller integrated into ET 200S (IEC 870-5-101/104
telecontrol protocols); for cost-sensitive applications, up to
approx. 30 I/O signals or approx. 200 data points
S7-300/S7-300F controller (SINAUT ST7, DNP3,
IEC 870-5-101/104 telecontrol protocols); for extremely
flexible configuration, up to 100 I/O signals or
approx. 2000 data points
S7-400/S7-400F controller (SINAUT ST7, DNP3,
IEC 870-5-101/104 telecontrol protocols);
up to 500 I/O signals or approx. 5000 data points
S7-400/S7-400F redundant controller (IEC 870-5-101/104 and
DNP3 telecontrol protocols); up to 500 I/O signals or approx.
5000 data points
Third-party station with the IEC 870-5-101/104 and DNP3
telecontrol protocols (depending on type of station)
ST80_2013_EN_Kap04.book Seite 135 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/TeleControl
4/136 Siemens ST 80 / ST PC · 2013
Integration (continued)
4
The following table provides an overview of the current options
for connecting to these outstations:
1)
Data buffering is limited to two SIMATIC S7 data blocks. Depending on the
SIMATIC CPU, this corresponds to approx. 800 to 3200 buffered frames.
Spectrum of outstations and integration versions
Telecontrol protocol SINAUT ST 7 DNP3 IEC 870-5-01 IEC 870-5-04
Type of communication Serial Ethernet TCP/IP Serial Ethernet TCP/IP Serial Ethernet TCP/IP
Interface TIM 4R-IE TCP/IP WAN
router or/and
TIM 4R-IE
TCP/IP
serial converter TCP/IP WAN
router TCP/IP
serial converter TCP/IP WAN router
RTU/interface ET 200S with
integr. CPU
(corresponding
to S7-314)
- - - - IM 151-7 CPU or
IM 151-8 PN/DP
CPU
as well as
1 SI module +
SIPLUS RIC library
IM 151-8 PN/DP
CPU
+ SIPLUS RIC
library
S7-300/S7-300F TIM 3V-IE TIM 3V-IE TIM 3V-IE DNP3 TIM 3V-IE DNP3 CP 341
+ SIPLUS RIC
library
CP 343 + IEC on
S7 or integr. PN
interface
+ SIPLUS RIC
library
S7-400/S7-400F TIM 4R-IE TIM 4R-IE TIM 4R-IE DNP3 TIM 4R-IE DNP3 CP 441
+ SIPLUS RIC
library
CP 443 + SIPLUS
RIC library or
integr. PN interface
+ SIPLUS RIC
library
S7-400H/
S7-400FH - - TIM 4R-IE DNP3 TIM 4R-IE DNP3 ET 200M + 2 x CP
341 + SIPLUS RIC
library
CP 443
+ SIPLUS RIC
library
Third-party
station - - Depends on type of station Depends on type of station
Dial-up lines • - • - - -
Dedicated line and
radio networks • • • •
Master/slave • • • •
Peer-to-peer - - •
Mesh networks • • • •
Time tagging in RTU • • • •
RTU time synchronization • • • •
Data buffering in RTU • • • •
1)
1)
Routing with SIMATIC PDM - - -
International standard - - • •
ST80_2013_EN_Kap04.book Seite 136 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/TeleControl
4/137
Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
More information
For an overview of the complete performance spectrum on the
Internet, visit:
Service & Support:
http://www.siemens.com/automation/csi_en_WW/service
(international)
Technical Support (hotline) for Automation & Drives:
http://www.siemens.com/automation/csi_en_WW/
support_request
(international)
SIMATIC TeleControl 7.0 SP2
for WinCC Basic Engineering 6DL5000-7AA07-0XA5
Software package with
SIMATIC TeleControl for WinCC 7.0
SP2 Engineering Software,
2 languages (English, German),
executable with Windows XP
Professional/Server 2003, Floating
License for one user; electronic
documentation on CD/DVD,
2 languages (English, German)
Type of delivery:
License key memory stick, Certificate
of License incl. terms and conditions,
SIMATIC WinCC Data Medium Pack-
age V7.0 + SP2 and CD "WinCC
TeleControl Option V7.0 + SP2"
SIMATIC TeleControl 7.0 SP2
for Server Runtime (6 stations) 6DL5002-7AA07-0XA0
Software package with
SIMATIC TeleControl for WinCC 7.0
SP2 Runtime Software, 2 languages
(English, German), executable with
Windows Server 2003, Single
License for one user; electronic
documentation on CD/DVD,
2 languages (English, German)
Type of delivery:
License key memory stick,
Certificate of License incl. terms
and conditions, SIMATIC WinCC
Data Medium Package V7.0 + SP2
and CD "WinCC TeleControl Option
V7.0 + SP2"
SIMATIC TeleControl 7.0 SP2
for Server Runtime (12 stations) 6DL5002-7AB07-0XA0
Software package with
SIMATIC TeleControl for WinCC 7.0
SP2 Runtime software, 2 languages
(English, German), executable with
Windows Server 2003, single
license for one user; electronic
documentation on CD/DVD,
2 languages (English, German)
Type of delivery:
License key memory stick,
Certificate of License incl. terms
and conditions, SIMATIC WinCC
Data Medium Package V7.0 + SP2
and CD "WinCC TeleControl Option
V7.0 + SP2"
SIMATIC TeleControl 7.0 SP2
for Server Runtime (256 stations) 6DL5002-7AE07-0XA0
Software package with
SIMATIC TeleControl for WinCC 7.0
SP2 Runtime software, 2 languages
(English, German), executable with
Windows Server 2003, single license
for one user; electronic documentation
on CD/DVD, 2 languages
(English, German)
Type of delivery:
License key memory stick, Certificate
of License incl. terms and conditions,
SIMATIC WinCC Data Medium Pack-
age V7.0 + SP2 and CD "WinCC
TeleControl Option V7.0 + SP2"
SIMATIC TeleControl 7.0 SP2
for Server Runtime
(unlimited stations)
6DL5002-7AF07-0XA0
Software package with
SIMATIC TeleControl for WinCC 7.0
SP2 Runtime Software, 2 languages
(English, German), executable with
Windows Server 2003, Single
License for one user; electronic
documentation on CD/DVD,
2 languages (English, German)
Type of delivery:
License key memory stick,
Certificate of License incl.
Terms and Conditions, SIMATIC
WinCC Data Medium Package V7.0
+ SP2 and CD "WinCC TeleControl
Option V7.0 + SP2"
Driver software
for telecontrol protocols
TeleControl SINAUT Driver
6DL5101-8AX00-0XB0
Runtime license for one
WinCC Single Station or one
WinCC server, Single License
for 1 installation
Requirement:
Software SIMATIC TeleControl 7.0
SP2 for WinCC Server Runtime
(6, 12, 256 stations)
Type of delivery:
License key memory stick,
Certificate of License incl. terms
and conditions
TeleControl DNP3 Driver 6DL5101-8EX00-0XB0
Runtime license for one
WinCC Single Station or one
WinCC server, single license
for 1 installation
Requirement:
Software SIMATIC TeleControl 7.0
SP2 for
WinCC Server Runtime
(6, 12, 256 stations)
Type of delivery:
License key memory stick,
Certificate of License incl. terms
and conditions
TeleControl IEC 870-5-101/-104
Driver 6DL5101-8CX00-0XB0
Runtime license for one
WinCC Single Station or one
WinCC server, single license
for 1 installation
Requirement:
Software SIMATIC TeleControl 7.0
SP2 for
WinCC Server Runtime
(6, 12, 256 stations)
Type of delivery:
License key memory stick,
Certificate of License incl. terms
and conditions
ST80_2013_EN_Kap04.book Seite 137 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/User Archives
4/138 Siemens ST 80 / ST PC · 2013
4
Overview
Option for SIMATIC WinCC for managing data sets in user
archives that contain related data.
WinCC and its automation partners (e.g. a SIMATIC S7
controller) write these data sets and exchange them if
required.
A license is only required for the server
(or single-user system).
The WinCC/User Archives option can also be used in the context
of the WinCC/Web Navigator (see also WinCC/Web Navigator
option).
Benefits
Storing and managing of any user data in data sets
Flexible display using ActiveX controls
Simple linking of data set fields to the process via direct tag
linking
Import/export functions for further processing with other tools
(e.g. MS Excel)
Function
Input of parameter sets (e.g. operating parameters of a
machine) in WinCC, storage of the sets in the user archive,
and forwarding to the automation level
Continuous acquisition of production parameters by the
automation system and forwarding of the parameters to
WinCC at the end of the shift
Acquisition of batch data
Specification of production parameters
Management of warehousing data
WinCC user archives are created and assigned data in a user-
friendly way using a dedicated editor. Special ActiveX controls
are used for displaying data from the user archives at runtime.
Data sets and fields from user archives are linked to the process
via direct tag linking.
Import and export functions support read-in/out of data via
external applications (e.g. MS Excel). Freely selectable filter
criteria allow clear representation of data sets.
WinCC provides functions for free organization of the data
storage in the user archives that affect archives, data sets and
fields. Archives can thus be generated, opened, closed, or
reset, and data sets or field contents can be read, written or
overwritten.
Sequence archives can accommodate batch data, shift
production data, or also product quality data, and meet legal
obligations for verification thanks to gap-free recording.
Ordering data
Order No.
SIMATIC WinCC/User Archives
• Option for SIMATIC WinCC V7.2,
Runtime software, single license 6AV6371-1CB07-2AX0
• Option for SIMATIC WinCC V7.0,
Runtime software, single license 6AV6371-1CB07-0AX0
• Option for SIMATIC WinCC V6.2,
Single license 6AV6371-1CB06-2AX0
ST80_2013_EN_Kap04.book Seite 138 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/Web Navigator
4/139
Siemens ST 80 / ST PC · 2013
Overview
Option for SIMATIC WinCC for operator control and monitoring
of plants via the Internet, in-house intranet or LAN
Configuration from:
- a Web server with the SIMATIC WinCC software as a single-
user, client or server version and a Web client that enables
operator control and monitoring of a current WinCC project
via an Internet browser with ActiveX support. The WinCC
basic system does not have to be installed on the client
computer. It is also possible to use the Web client without
Microsoft Internet Explorer.
• Licensing:
- A license is required in order to use the Web server.
- Licenses are available for access to the Web server
by 1, 3, 5, 10, 25, 50, 100 or 150 clients.
- Low-priced WebNavigator diagnostics licenses are
available for the remote diagnostics via multiple, distributed
Web servers.
WinCC
SCADA client
+ Web server
WinCC
Web client
WinCC
SCADA clients
WinCC
DataMonitor
WinCC
Web client
WinCC
DataMonitor
WinCC server
(max. 18)
Internet
G_ST80_XX_00021
PROFIBUS
PROFINET
LAN
ST80_2013_EN_Kap04.book Seite 139 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/Web Navigator
4/140 Siemens ST 80 / ST PC · 2013
Overview (continued)
4
Highlights:
Installation of the Web server - in distributed systems - also on
a WinCC Client;
- Access to as many as 18 subordinate WinCC stations
(servers) possible
- Web clients offer common views of data on various
WinCC Servers
- If you are using WinCC/Redundancy, the Web clients will
also transfer via the subordinate WinCC servers (requires
WebNavigator server to be installed on the WinCC Client
(RT128) )
- Separating the Web functionality from the WinCC data
servers makes the overall system safer and more scalable in
respect of load. Integrated user management with WinCC:
The configured WinCC operator authorizations are taken into
account on the Web client.
Access to WebNavigator server from the WebNavigator
TIA Portal series of products.
Access to user archives.
VB scripts are supported in the same way as the new objects
and RT functions in WinCC V7.x.
User-friendly services and tools for distributing customized
objects (controls, files) to Web clients can be supplied for use
as an integration platform. These components can then also
be integrated into cross-Web/Server navigation.
Distribution of load across a number of Web servers in order
to run several hundred Web clients in a single system; Web
clients are distributed across Web servers automatically.
Version 7.2 supports Microsoft Internet Explorer Version 8.0
and 9.0, including tabbed browsing. A new license is not
required for separate tabs.
With the WinCC Web Viewer, the process screens can be
displayed on the Web client independently of the Internet
Explorer. Settings for the client are made on the client itself.
The WinCC Web Viewer can also be used in conjunction with
the Microsoft Terminal Service.
From version 7 on, the WebNavigator can also be operated in
"view only" mode and is thus used as tool for operating and
navigating only via WinCC screens by means of the Internet
Explorer.
The cursor for View only mode can be selected according to
individual requirements.
Web server logins and logouts are recorded in the alarm and
audit archive.
There is a gadget available for the Windows 7 operating
system in which selected WinCC process screens can be
displayed. The gadget does not require any additional
WebNavigator license. The WebNavigator server can be
selected direct using the gadget.
Security is increased by adjustable automatic logout. If an
automatic logout is to take place, an absolute or inactive time
period can be set.
Runtime in the Web client can be terminated by means of
scripting.
Benefits
Operator control and monitoring across long distances and on
different platforms (PC, local panel, mobile PDA)
Large configurations with up to 150 operator stations
Fast updating rates thanks to event-driven communication
Optimally tailored clients for operating and monitoring,
analysis, service and diagnostics
Acceptance of configuration data for the Web, generally
without changes
Minimum maintenance costs thanks to centralized software
administration
High security standards and availability
- Increased security due to separation of WinCC server and
Web server (Web server in secure environment)
- Support for commonly used security mechanisms
(routers, firewalls, proxy servers)
- Access authorization and user administration
New in V7.2
New license stages for 1, 5, 100, 150 clients and associated
powerpacks 1/3, 3/5, 50/100, 100/150
Unicode support
PDL password protection with WebNavigator PDLPad
Login / logout / register:
Log user in/out on the WebNavigator client
Manual logout in the Internet Explorer by means of
ODK C-Script (PWRTLogout function)
Configurable logout/login in the WinCC RT Viewer
Application
In addition to the typical use of the Web Navigator in WANs
(Wide Area Network), the Web Navigator is also suitable for
solving especially low-cost applications. This especially
includes applications that have a pronounced distributed
structure (water/wastewater, oil & gas), or in which access to
process information is only sporadic (building management).
The Web Navigator also permits vertical integration, i.e. a
networked IT landscape with integrated data flow between the
planning and operating levels within a company. Only a
standard browser is required for direct access to current
process information.
The Web Server can have its own dedicated direct process
connection. An alternative is coupling via OPC or the use of a
remote Web Server to a WinCC Client. This simultaneously
increases security and reduces the communication load of the
plant.
In addition to the Standard Web Navigator licensing there is the
so-called Diagnostics Client, with identical functions in principle,
but which is especially suitable for the following applications:
Remote diagnostics/operation of several unmanned
WinCC stations.
Central control rooms which monitor multiple Web Servers on
one user interface.
Power Users that always require guaranteed access to the
server regardless of the number of users already logged on to
the server.
ST80_2013_EN_Kap04.book Seite 140 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/Web Navigator
4/141
Siemens ST 80 / ST PC · 2013
Design
Licenses for the Web Navigator
The Web Navigator Client software can be installed as many
times as required without the need for a license.
Server-based licensing;
a license is required in order to use the Web Navigator Server.
Licenses are available for simultaneous access to the Web
server by 1, 3, 5, 10, 25, 50, 100 or 150 clients.
Diagnostics client licensing;
for optimum-cost access by one or a small number of Web
Navigator Clients to numerous Web servers (e.g., for the
purpose of diagnostics). This client license provides
guaranteed access to Web servers at any time. In respect of
function there is no difference compared with regular Web
Navigator Clients and the two can be mixed.
Web Navigator Clients can:
Access a number of different web servers or
Access data on a number of higher-level WinCC stations
simultaneously via a remote Web server
On the server side, only one Web Navigator Diagnostics Server
license or, alternatively, one Standard Web Navigator license is
required.
Alternatively, a number of Web Navigator Servers with the same
WinCC project can be combined to create a "server farm". This
means that it is possible for several hundred Web clients to have
access to the same database. The service ensures that the
clients accessing are distributed evenly across all servers. If a
server fails the Web client is automatically forwarded to the next
available server.
In order to use this functionality you will need to install a Web
Load Balancing license on the Web servers involved. Each Load
Balance package contains 2 licenses.
An inexpensive expansion option for Web Load Balancing is
available for redundant WinCC stations on which the Web
Navigator is also installed. For this purpose, you need to install
a Web Load Balancing Step Up license on the web servers
involved. Each Step Up package contains 2 licenses.
Thin Client solutions
The Web Navigator can also run under Windows Server 2003 or
Windows Server 2008 terminal services. A Windows Server 2003
or Windows Server 2008 (or higher) operating system is
required. This makes it possible to connect SIMATIC Thin Clients
as visualization stations to WinCC, for example.
For this purpose, the Windows terminal services must be
installed on the PC on which the Web client is installed. A
Windows Server 2003 or Windows Server 2008 (or higher)
operating system is required. Up to 25 ThinClients can be
connected to one terminal server.
Applications:
Mobile devices
•Handhelds
Rugged on-site visualizations
Hybrid configuration
Web Navigator and DataMonitor clients can be mixed in a single
system.
Function
The Web Configurator (Wizard) makes setting up and config-
uring a Web Navigator Server very easy. WinCC process
screens to be visualized via the Internet are created as usual
using WinCC Graphics Designer. Under normal circumstances
the project can be worked on locally without modification. The
Web Publishing Wizard optimizes the screens for transmission
and display on the Internet. A standard browser is all that is
required to display WinCC process screens on the Web Client.
The MS Internet Explorer is used depending on the Web
Navigator version used (tip: start the Internet Explorer in full-
screen mode with the start parameter "-k").
The operator on the Web Client is integrated in the central
WinCC user administration and can operate and monitor the
system according to the configured access rights. The Web
Navigator supports all standard security mechanisms that can
be used for applications on the Internet, e.g. routers, firewalls
and proxy servers.
ST80_2013_EN_Kap04.book Seite 141 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/Web Navigator
4/142 Siemens ST 80 / ST PC · 2013
4
Ordering data
Order No. Order No.
WinCC/Web Navigator
V7.2; for WinCC V7.2
1 client license 6AV6371-1DH07-2LX0
3 client licenses 6AV6371-1DH07-2AX0
5 client licenses 6AV6371-1DH07-2MX0
10 client licenses 6AV6371-1DH07-2BX0
25 client licenses 6AV6371-1DH07-2CX0
50 client licenses 6AV6371-1DH07-2DX0
• 100 client licenses 6AV6371-1DH07-2GX0
• 150 client licenses 6AV6371-1DH07-2HX0
WinCC/Web Navigator
Powerpacks V7.2
From 1 to 3 clients 6AV6371-1DH07-2LA0
From 3 to 5 clients 6AV6371-1DH07-2AM0
• From 5 to 10 clients 6AV6371-1DH07-2MB0
• From 10 to 25 clients 6AV6371-1DH07-2BC0
• From 25 to 50 clients 6AV6371-1DH07-2CD0
• From 50 to 100 clients 6AV9681-1DH07-2DG0
• From 100 to 150 clients 6AV9681-1DH07-2GH0
WinCC/Web Navigator
Diagnostics Client
for WinCC V7.2 6AV6371-1DH07-2EX0
WinCC/Web Navigator
Diagnostics Server
for WinCC V7.2 6AV6371-1DH07-2FX0
WinCC/Web Navigator upgrade
V6.0 to V7.0; V6.2 to V7.0;
V6.2 to V7.2 Included in correspond-
ing WinCC upgrade
• For 3, 10, 25, 50 clients
Diagnostics server and
diagnostics client
Load Balancing
WinCC/Web Load Balancing V7.2
Load Balancing 6AV6371-1DH07-2JX0
• Load Balancing Step Up 6AV6371-1DH07-2FJ0
V7.0; for WinCC V7.0,
WinCC V7.0 SP1/SP2/SP3 and
WinCC V7.0 SP1/SP2/SP3 ASIA
• Base Pack (3 client licenses) 6AV6371-1DH07-0AX0
• 10 client licenses 6AV6371-1DH07-0BX0
• 25 client licenses 6AV6371-1DH07-0CX0
• 50 client licenses 6AV6371-1DH07-0DX0
WinCC/Web Navigator
Powerpacks V7.0
• From 3 to 10 clients 6AV6371-1DH07-0AB0
• From 10 to 25 clients 6AV6371-1DH07-0BC0
• From 25 to 50 clients 6AV6371-1DH07-0CD0
WinCC/Web Navigator
Diagnostics Client
• for WinCC V7.0 6AV6371-1DH07-0EX0
WinCC/Web Navigator
Diagnostics Server
• for WinCC V7.0 6AV6371-1DH07-0FX0
WinCC/Web Navigator upgrade
V6.0 to V7.0
• For 3 clients 6AV6371-1DH07-0AX4
• For 10 clients 6AV6371-1DH07-0BX4
• For 25 clients 6AV6371-1DH07-0CX4
• For 50 clients 6AV6371-1DH07-0DX4
V6.2 to V7.0
• For 3 clients 6AV6371-1DH07-0AX3
• For 10 clients 6AV6371-1DH07-0BX3
• For 25 clients 6AV6371-1DH07-0CX3
• For 50 clients 6AV6371-1DH07-0DX3
V6.x to V7.0
• For Web Navigator
Diagnostics Client 6AV6371-1DH07-0EX4
• For Web Navigator
Diagnostics Server 6AV6371-1DH07-0FX4
WinCC/Web Load Balancing V7.0
• Load Balancing 6AV6371-1DH07-0JX0
• Load Balancing Step Up 6AV6371-1DH07-0FJ0
ST80_2013_EN_Kap04.book Seite 142 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC WinCC options
WinCC/Web Navigator
4/143
Siemens ST 80 / ST PC · 2013
Ordering data
Order No.
1)
Including upgrade for diagnostics client, diagnostics server, Web Load
Balancing and Web Load Balancing Step Up.
More information
System requirements – Web server
For WinCC/Web Navigator V7.2
Windows 7 SP1 (32- and 64-bit) Business, Enterprise and
Ultimate (max. 3 clients)
Windows XP Professional Service Pack 3 (max. 3 clients)
Windows Server 2003 SP2
Windows Server 2008 SP2 32-bit
Windows Server 2008 R2 SP1 64-bit
Internet Explorer V7.0, V8.0 and V9.0
Microsoft SQL Server 2008 R2 SP1, 32-bit
(included in the WinCC product delivery)
For WinCC/Web Navigator V7.0
Windows 7 (32-bit) Business, Enterprise and Ultimate
(max. 3 clients)
Windows XP Professional Service Pack 3 (max. 3 clients)
Windows Server 2003 SP2 and Windows Server 2003 R2 SP2
Windows Server 2008 SP2
Internet Explorer V6.0 SP1 or SP2 as well as Internet Explorer
V7.0.
Microsoft SQL Server 2005 SP2 (scope of supply of WinCC)
WinCC Basic System V7.0 SP2
For WinCC/Web Navigator V6.2 SP3
Windows 2000 Professional Service Pack 4 (max. 3 clients)
Windows XP Professional or Service Pack 3 (max. 3 clients)
Windows Server 2003 SP2 or Windows Server 2003 R2 SP2
Internet Explorer 6.0 SP1, SP2 or 7.0 (without multitabbing)
Microsoft SQL Server 2005 SP1 (scope of supply of WinCC)
WinCC basic system V6.2 SP3
System requirements –Web client
For WinCC/Web Navigator V7.0
Internet Explorer V6.0 SP1 or SP2 as well as Internet Explorer
V7.0
For WinCC/Web Navigator V6.2 SP3
Internet Explorer 6.0 SP1, SP2 or 7.0 (without multitabbing)
WinCC Web Navigator V6.2 SP3 ASIA
(requires SIMATIC WinCC V6.2 SP3 ASIA)
The functions included in this version differ from the standard
version of WinCC/Web Navigator V6.2 SP3 as follows:
This version does not allow an Asian Web Navigator client to
access a non-Asian server and vice versa.
WinCC/Web Navigator
V6.2 SP3; for WinCC V6.2 SP3
Base Pack (3 client licenses) 6AV6371-1DH06-2AX0
10 client licenses 6AV6371-1DH06-2BX0
25 client licenses 6AV6371-1DH06-2CX0
50 client licenses 6AV6371-1DH06-2DX0
V6.2 SP3 ASIA; for WinCC V6.2
SP3 ASIA
Base Pack (3 client licenses) 6AV6371-1DH06-2AV0
10 client licenses 6AV6371-1DH06-2BV0
25 client licenses 6AV6371-1DH06-2CV0
50 client licenses 6AV6371-1DH06-2DV0
WinCC/Web Navigator
Powerpacks
V6.2 (for ASIA variants as well)
• From 3 to 10 clients 6AV6371-1DH06-2AB0
• From 10 to 25 clients 6AV6371-1DH06-2BC0
• From 25 to 50 clients 6AV6371-1DH06-2CD0
WinCC/Web Navigator
Diagnostics Client
for WinCC V6.2 SP3 6AV6371-1DH06-2EX0
for WinCC V6.2 SP3 ASIA 6AV6371-1DH06-2EV0
WinCC/Web Navigator
Diagnostics Server
for WinCC V6.2 SP3 6AV6371-1DH06-2FX0
for WinCC V6.2 SP3 ASIA 6AV6371-1DH06-2FV0
WinCC/Web Navigator upgrade
V1.x to V6.2 SP3
• For 3 clients 6AV6371-1DH06-2AX4
• For 10 clients 6AV6371-1DH06-2BX4
• For 25 clients 6AV6371-1DH06-2CX4
• For 50 clients 6AV6371-1DH06-2DX4
V6.x to V6.2 SP3
• For 3, 10, 25, 50 clients
1)
6AV6371-1DH06-2XX3
• For Web Navigator
Diagnostics Client 6AV6371-1DH06-2EX3
• For Web Navigator
Diagnostics Server 6AV6371-1DH06-2FX3
V6.x ASIA to V6.2 SP3 ASIA
• For 3, 10, 25, 50 clients
1)
6AV6371-1DH06-2XV3
WinCC/Web Load Balancing V6.2
SP3
• Web Load Balancing (2 licenses) 6AV6371-1DH06-2JX0
• Web Load Balancing Step Up
(2 licenses) 6AV6371-1DH06-2FJ0
ST80_2013_EN_Kap04.book Seite 143 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
WinCC add-ons und partner management
WinCC add-ons and partner management
4/144 Siemens ST 80 / ST PC · 2013
4
Overview
WinCC Premium Add-ons – Solutions for all sectors and
technologies
The basic system is designed to be independent of any specific
technology or industrial sector, to be modular and flexibly
expandable and to permit not only simple single-user applica-
tions in machine construction, but also complex multi-user
solutions or even distributed systems with several servers and
clients in plant engineering. WinCC Premium Add-ons are
supplementary products that have been created by competent
partners working in the specifc sectors and technologies and
represent interesting expansions for WinCC.
WinCC Premium Add-ons are not IA (Siemens Industry
Automation) products, but the products of partners who are
committed to complying with certain quality features and
boundary conditions. The Premium Add-ons are checked, for
example, in the Siemens Test Center for their compatibility with
the basic WinCC system and supported in the first instance by
the central Hotline. As they are important application- and
sector-specific add-on products for SIMATIC WinCC, they are
marketed jointly by Siemens and the respective add-on
suppliers. The WinCC Premium Add-on products can be found
on the Internet (see Further Information) and in the "Online
WinCC Premium Add-on Catalog".
Premium Add-ons for Connectivity:
PM OPEN IMPORT system software
for importing WinCC flexible archives into the WinCC system.
PM OPEN EXPORT system software
for exporting WinCC data to local storage media or storage
media released in the network.
PM OPEN TCP/IP system software
permits bidirectional exchange of WinCC data (tags,
messages) with one or more computers that communicate
using the TCP/IP protocol.
Historian CONNECT ALARM system software
permits importing of messages and alarms from WinCC and
WinCC flexible into the SIMATIC IT Historian.
TOP Server/TOP Server UCON
expands OPC-based the connection capability for WinCC &
WinCC flexible Advanced (PC based runtime)
Premium Add-on for process management:
PM CONTROL system software
is a recipe system for user-friendly generation and modifi-
cation of recipes.
PM QUALITY system software
is an archive system for the administration of job and batch-
related production and process data.
Premium Add-on for sector products:
Library SENTRON PAC3200 for SIMATIC WinCC
permits seamless integration of the SENTRON PAC3200 multi-
functional measuring instrument in WinCC.
Sm@rtlib function library
provides function blocks for S7-300/400 as well as faceplates
and icons for WinCC and WinCC flexible from the areas of
process industry, HVAC, pharmaceuticals and energy.
ACRON for WinCC/PCS 7
is used for long-term archiving and logging of process data for
small to medium-sized plants, specifically in the water supply
and treatment industry.
Premium Add-on for configuration tools:
DCC TranslationEditor
for translating multilingual projects with in-built security,
convenience and globalization features.
Premium Add-on for diagnostics and maintenance:
Management System Alarm Control Center
for transmitting fault messages via various communication
paths, such as GSM, LAN, e-mail.
PM MAINT system software
is a tool for the maintenance of production plants.
PM ANALYZE system software
for analysis of fault and operating messages, as well as
process values.
G_ST80_XX_00175
WinCC
Basis-SW
RC, RT
WinCC
Add-on
WinCC
Option
WinCC
Option
WinCC
Option
WinCC
Add-on
WinCC
Add-on
ST80_2013_EN_Kap04.book Seite 144 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
WinCC add-ons und partner management
WinCC add-ons and partner management
4/145
Siemens ST 80 / ST PC · 2013
Overview (continued)
Competent partners
With SIMATIC WinCC, you not only get excellent products to suit
your requirements, but we will also support you with selecting a
partner for your automation solution. In our global network of
Siemens Automation Solution Providers you will always find
competent partners in your neighborhood. In addition, we
implement and support the Siemens-internal WinCC Compe-
tence Centers and the WinCC Professionals external system
integrators on the basis of WinCC customer- and industry-
specific and economic solutions.
WinCC Competence Centers
Mannheim
Emphasis on process management
Sector-independent solutions and products in the fields:
Production, environmental protection, maintenance and
diagnostics
Connectivity tools, system integration, connection to SAP R/3
Support of FDA validation and WinCC ODK
Support for advanced users with application of ODK and VBA
Customer-specific software development for panels,
PCs/IPCs, and servers
Consulting on web technologies, web servers/thin clients,
DataMonitor
Customer-specific workshops, e.g. VBS, VBA, and all
WinCC options, e.g. Process Historian
Information Server and other WinCC topics according to
customer requirements
Stuttgart
Emphasis on production technology
Solutions for maintenance management
Web-based solutions with WinCC
Nuremberg
Solutions in the Oil & Gas, Metal & Mining, Pulp & Paper sectors
Network and security
Microsoft Certified
Migration from COROS to WinCC
Customized expansions also for WinCC flexible
Web solutions
Customer-specific workshops, e.g. training courses for VBS,
VBA, web technologies à Web Server/Thin Client, DataMonitor
à Webcenter Reports, Excell Workbook, and all WinCC topics
as required by the customer (the latter with lead time)
Further information can be found in the Internet at:
http://www.siemens.com/wincc/competencecenter
More information
WinCC Competence Center
http://www.siemens.com/winCC/competencecenter
Siemens Solution Partner Automation
http://www.siemens.com/automation/solutionpartner
WinCC Premium Add-on
http://www.siemens.com/winCC/addons
ST80_2013_EN_Kap04.book Seite 145 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture
4/146 Siemens ST 80 / ST PC · 2013
4
Overview
SIMATIC WinCC Open Architecture is a SCADA system for
visualizing and operating processes, production flows,
machines and plants in all industrial sectors.
SIMATIC WinCC OA relies throughout on object-oriented struc-
tures. Due to this consistent and well-considered use of object-
oriented structures, from process pictures to the database, the
engineering costs improve for SIMATIC WinCC OA customers.
Distributed systems enable the connection of up to
2048 autonomous SIMATIC WinCC Open Architecture systems
via one network. Each subsystem can be configured either as
single-user or multi-user system, each of which may be
redundant or non-redundant.
Current version: SIMATIC WinCC Open Architecture V3.11
Runs on:
- Windows 8 Enterprise (64-bit)
- Windows 7 Ultimate/Enterprise/Professional SP1 (32/64-bit)
- Windows XP SP2/SP3 (32-bit)
- Windows Server 2008 R2 (64-bit)
- Red Hat Linux 5 (32/64-bit)
- OpenSuse 12.1 (32/64-bit)
- Sun Solaris 10 SPARC (32-bit)
- Sun Solaris 10 x86 (64-bit)
- VMWare ESXi Version 4.0.0 & 5.0.0
Note
Native 64-bit support on 64-bit systems.
Benefits
Efficient engineering and flexible plant expansion
- Object orientation
- Unlimited number of data points
- Mass engineering
- Multilingual with UTF-8 support
Object-oriented data model
- Mapping of setpoint values and measured values for a
physical plant object onto a structured data point
- Data point comprises a tree structure with data point
elements
- The individual process values are mapped onto the data
point elements
- Any number of data points can be instanced from one
defined data point structure (data point type), e.g. 20 pumps
of the same type.
- Data point types can be embedded in other data point types,
which enables more complex plant objects to be generated
(e.g. one pump station comprises 2 pumps).
- Graphical plant symbols can be linked with a data point
type, in which case they only need to be drawn once, but can
be used for all instances of the linked type.
- Savings in engineering outlay.
Freely scalable
- From a small single-user system up to a networked,
redundant high-end system
- Distributed systems of up to 2048 servers
• Platform-independent
- Available for Windows, Linux and Solaris
Native 64-bit support
- More system memory is usable, due to native 64-bit support
- This means that larger data quantity structures per server
can be processed
Maximum fail-safety and availability
- Hot standby redundancy
- Disaster recovery system
- SIL3 certification according to IEC 61508
Platform for customized solutions
- Quick and easy implementation of new processes
- Swift adaptation of the control and visualization of the plant
to current market requirements
- Company-internal programming and in-house develop-
ments enable independence and protection of intellectual
property
- Structure of standardized solutions permits continuous use
- Support of brand-labeling
- Individual brand names for OEM developments
Openness thanks to comprehensive driver and interface
options:
- Modbus serial, Modbus Plus / RS485, RK512, TLS, Teleperm
M, SSI driver, IEC 60870-5-101, -104, DNP3, SINAUT,
PROFIBUS DP, PROFIBUS S7 + MPI, S7 TCP/IP, Modbus
TCP/IP, Ethernet/IP, OPC DA Client & Server, OPC A&E Client
& Server, OPC UA Client & Server (DA, AC), SNMP, BACnet,
API, Kerberus
Seamless traceability of system states by means of high-
performance archiving:
- Data archiving in value archives (internal database format)
- Data archiving in an Oracle database
Expandable by means of add-ons and solution frameworks:
- Add-on for quick and easy engineering (Etool, AdvS7, etc.)
- Add-on for increasing the availability (DRS, etc.)
- Add-on for clarity in distributed systems (GIS Viewer, etc.)
- Add-on for efficient maintenance management
(AMS, Scheduler, etc.)
- Add-on for mobile operability
(Web Client, Ultralight Client, etc.)
- Add-on for efficient building automation technology
(BacNet, etc.)
- Add-on for the integration of video management
ST80_2013_EN_Kap04.book Seite 146 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture
4/147
Siemens ST 80 / ST PC · 2013
Application
The SCADA system SIMATIC WinCC Open Architecture
addresses applications with high demand for customer-specific
adaptations, large and/or complex applications, as well as
projects that demand special system requirements and
functions.
SIMATIC WinCC Open Architecture demonstrates its high
performance in networked and redundant high-end control
systems in particular. Integrated, high-performance communi-
cation is guaranteed from the field level to the control station,
from the machine to the company headquarters. In every
situation, high availability, reliable information, fast interaction,
and user friendliness are guaranteed. Applications can also be
changed without interrupting the process. Profitability, efficiency
and safety are therefore always in equilibrium. SIMATIC WinCC
Open Architecture displays its reliability in a wide range of
business-critical applications.
With SIMATIC WinCC Open Architecture, ideas can be quickly
and easily converted into new applications. SIMATIC WinCC
Open Architecture is open for independent in-house develop-
ments and also enables own product branding.
Thanks to its special system properties, SIMATIC WinCC Open
Architecture meets the highest demands especially in the case
of traffic solutions, building management systems and supply
systems (power, water, oil and gas, etc.).
Design
SIMATIC WinCC Open Architecture is available as a single-user
runtime license, multi-user runtime license, Web Client license,
and parameterization and development license. With SIMATIC
WinCC Open Architecture the required license is determined,
among other things, according to the number of inputs and
outputs (I/O).
An "I/O" refers to a data point element (DPE) whose content is
exchanged either by means of drivers (e.g. S7 driver communi-
cates with a PLC), with other software systems. Internal data
point elements, i.e. DPEs without communication to the outside,
are not counted for licensing. The licenses are available either
with an unlimited number of I/Os or with limitations of 500 to
250 000 I/Os.
The multi-user runtime license allows working simultaneously
from different PCs, with the licensing taking place via the server.
The active clients are then counted. The web client and the ultra-
light client enable the visualization and operation of process
pictures over an exclusively HTTP connection between the
server and the respective web client. The parameterization and
development licenses extend a runtime license with the option of
configuration and parameterization. They each require a server
license.
Function
SIMATIC WinCC Open Architecture is a very modular SCADA
system. The required functionalities are realized by specific,
functional entities created for various tasks. In SIMATIC WinCC
Open Architecture these units are called "Managers" – they are
also independent processes in software terms.
WinCC OA Manager Task
Event Manager (EV) The Event Manager (EV) is the processing center
in WinCC OA. This unit provides a constantly
updated image of all PowerTags in the memory.
Each other functional unit (Manager) that wants to
access the data receives it from the process
image of the Event Manager and does not have to
communicate directly with a controller. Conversely,
a command from an operator station is initially set
only as a value change in the process image of the
Event Manager. The associated driver then for-
wards it to the corresponding target device
(e.g. PLC) automatically.
The Event Manager is a kind of central data dis-
tributor, in effect the communication center for
WinCC OA. Furthermore, this Manager also carries
out the alarm handling and can execute various
arithmetic functions autonomously.
Driver Manager (D) The lowest level in a WinCC OA System is repre-
sented by the process connections, referred to in
WinCC OA as drivers (D). These are special pro-
grams that handle the communication with the
control and field level. Since numerous different
forms of communication are possible with the
PLCs or telecontrol nodes, there are different driv-
ers that can be selected. In very simple terms, the
driver is a unit for converting a particular protocol
into the internal communication form of WinCC
OA. The driver reads the current states, measure-
ment or counter values from the field and in the
opposite direction it forwards commands and set-
points to the lower-level controllers (= the term
"control" should be used here and below to repre-
sent all possible devices of the basic automation
(PLC, DDC, telecontrol system, etc.)).
Data Manager (DB) The Data Manager (DB) represents the link to
database. On one hand, it involves the parameter-
ization data of an application that is to be stored in
such a database. On the other hand, it involves the
historical recording of changes in values or
alarms. If a user wishes to query historical data at
a later date, then the Data Manager completes this
request and not the database itself.
ST80_2013_EN_Kap04.book Seite 147 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture
4/148 Siemens ST 80 / ST PC · 2013
Function (continued)
4
A WinCC OA System consists of function-specific units, the managers
For special tasks such as redundancy, management for
distributed systems, web server, reporting, simulation, COM
etc., further managers are available.
The powerful configuration functions contribute to a reduction of
engineering and training overheads and lead to increased flexi-
bility and operational reliability.
Control Manager
(CTRL) WinCC OA has numerous options for implement-
ing your own algorithms and processing. The two
most important are the internal language control
(CTRL) and the general application programming
interface (API).
Control is an extremely powerful scripting lan-
guage. The processing is interpretative, so that no
compilation is required. The syntax is almost iden-
tical with ANSI-C, with some modifications for sim-
plification. This is a fully developed, procedural
high-level language with multi-threading (= quasi-
parallel processing of individual programs; the
system itself carries out the processing check).
The language offers a comprehensive function
library for tasks of the control and visualization
technology. Control can be used as a stand-alone
process (Control Manager), for animation and user
interface design or for standardized, data object-
oriented processing functions.
The API (WinCC OA API) represents the most pow-
erful form of functional expansion. It is configured
as a C++ class library and allows the software
developer to implement individual functions as an
independent, additional manager (forecast sys-
tem, simulation, tools, proprietary databases,
etc. ).
User Interface
Manager (UI) The interface to the user is created by the User
Interface Manager (UI). This comprises a graphics
editor (GEDI), a database editor (PARA) or the
general user interface of the application (Vision
module). The User Interface serves to display val-
ues, issue commands or track alarms in the alarm
list. Trends and reports are also usually part of the
UI. From a programming viewpoint, the user inter-
action in WinCC OA is completely isolated from the
background processing – this is merely a view of
the data of the current process image or the his-
tory.
WinCC OA Manager Task
Visualization, Operation
Driver: PLC, Field busses, DDC,
Telemetry/RTU, Special drivers
Process Interface
Communication
and Alarming
History
=
=
=
=
=
=
=
Event manager
Data manager,
RDB
Process Image, History
Script language
Application
Programming
Interface
Control
Manager
API
Processing, Control
Runtime
Graphical Editor
Database Editor
UI
GEDI
PARA
G_ST80_XX_00463
User-
interface
Editorr
User-
interface
Runtimee
User-
interface
Runtimee
Control
manager
API
manager
Database
manager
Event
manager
Connection
to other
systems
Driver Driver Driver
D
D
D
CONEVDB
APICTRL
UIUIUI
Special functions Task
Access to external
databases The database interfaces offer the possibility of
access to external databases.
Under Windows, the link is established via the
ADO Standard. ADO (ActiveX Data Objects) is an
interface developed by Microsoft for vendor-inde-
pendent access to data sources of all types, pri-
marily databases. The data source for ADO is an
OLE DB Provider, although ODBC-compatible
databases can also be addressed via an internal
wrapper.
In Linux, the Qt library is used as an interface to
relational databases. Access in this case is either
direct via the native DB-API or via ODBC.
Application Program-
ming Interface (API) The API offers a series of functions that enable
WinCC OA to be extended with special managers.
A manager means a program that communicates
with the system by via a protocol defined by
WinCC OA.
COM (Component
Object Model) This is a specification for the development of mod-
ular software components that can be used by
each COM-compatible application.
COM components can easily be integrated into
such applications and can even be removed from
an application during runtime. COM components
can be programmed in a host of different lan-
guages, even though C++ is usually used for this
purpose. The specifications OLE, ActiveX and
DirectX are based on the COM technology.
Control expansion Expansion that allows C++ functions to be added
to the programming language.
Panel topology/
summation signal Generation of panel hierarchies/topologies in
existing or new projects and automatic creation of
summation signals of the alarm data points that
are located in the panels of the topology.
Redundancy
(see figure below) The failure safety in a redundant system is imple-
mented by means of hot standby.
Hot standby is a hardware-independent solution
for high availability. This is a safety concept that
consists of two interconnected server systems.
Both servers are constantly in operation and are
subject to the same functional loading (but only
one server is ever active; the second compares
the data with the primary unit at runtime).
On the failure of one unit, an "on-the-fly
changeover" takes place and the previously
passive server assumes the leading role. This
guarantees access to data or functions at all
times.
ST80_2013_EN_Kap04.book Seite 148 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture
4/149
Siemens ST 80 / ST PC · 2013
Function (continued)
The diagram shows a detailed representation of the two
computers Server 1 and Server 2. Server 1 is in the management
mode (active) and Server 2 is in hot standby mode (passive).
In the case of redundant operation, the UIs of both operator
stations are connected to both Event Managers, however only
the data of the active system is displayed on both UIs.
The Event Manager of the passive system is restricted exclu-
sively to communication with the Event Manager of the active
system for comparison of the process data (it sends no data to
the connected UIs or it discards messages from the drivers – this
can be seen in the figure with the switches on the UIs or on the
passive Event Manager).
SMS Allows the sending and receiving of text messages
with WinCC OA.
Encryption of panels
and CTRL scripts/
libraries
Allows your panels or scripts to be encrypted,
thereby protecting your knowledge and work.
Script Wizard Easy-to-use tool that simplifies the creation of ani-
mated, graphical plant symbols, which saves time
during engineering.
Simple Symbols Basic package of plant symbols that have been
created using the script wizard. These can be
adapted quickly and easily to the specific require-
ments of the customer.
Easy Faceplates Simple parameter assignment of predefined pop-
up windows that display details of the associated
plant symbol. Without any additional drawing out-
lay, several standard functions per object can be
activated for the detail view (alarm display, trend
display, measured value table, setpoint value
table, address table, notes).
Special functions Task
Drag and Draw Several representative graphical objects can be
defined and configured for each plant object in the
data model (data point type). These are pre-con-
figured and need only be moved to the panel via
drag-and-drop when the plant pictures are drawn.
This saves valuable time during engineering.
Distributed systems
(see the diagram
below)
Permits the coupling of two or more autonomous
WinCC OA systems via a network. Each subsys-
tem of a distributed system can be configured
either as a single-user or multi-user system, each
of which may be redundant or non-redundant.
A sub-system in this context means a server on
which an Event Manager is running, whereby in
case of redundancy both redundantly operating
servers are considered as one system.
Special functions Task
ACTIVE HOT-STANDBY
Operational station 1 Operational station 2
Process connection Process connection
Message direction
User-
interface
Runtime
UI
User-
interface
Runtime
UI
Event
manager
Control
manager
CTRL
Database
manager
DB
CTRL
Control
manager
Database
manager
DB
Event
manager
EV
Redun-
dancy
manager
REDU Redun-
dancy
manager
REDU
Driver
DDriver
D
Server 1 Server 2
G_ST80_XX_00479
ST80_2013_EN_Kap04.book Seite 149 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture
4/150 Siemens ST 80 / ST PC · 2013
4
Integration
Integration in automation solutions
SIMATIC WinCC Open Architecture is an open SCADA system
with comprehensive drivers and flexible options for connection
to other external systems.
Depending on the communications protocol and the bus
physics used, specific drivers are used in each case:
Serial protocols: RK512, 3964R, etc.
Ethernet: Industrial Ethernet (S7), Modbus TCP
(OpenModbus), Ethernet IP (AB), etc.
Telecontrol systems: SINAUT, SSI (Ethernet),
IEC 60870-5-101, IEC 60870-5-104, etc.
Vendor-independent interfaces: OPC UA, etc.
In SIMATIC WinCC Open Architecture, several drivers can be
operated in parallel. These can be of the same type or also of
different types. It is possible in a SIMATIC WinCC Open Archi-
tecture system, for example, to establish connections via the
S7 protocol to a SIMATIC controller, via IEC 60870-5-104 to a
telecontrol system, and via OPC DA to any OPC server at the
same time.
Coupling overview
Protocol Description
SIMATIC S7 via TCP/IP and MPI
OPC Client
(Data Access) • Compatibility with the specifications DA 1.0
and 2.05a
• Connection to inproc, local or remote server
• Connection with up to 20 servers at the same
time
• Monitoring of the connection to the server
and automatic reconnection if the connection
is interrupted.
• Address browsing if supported by the server.
Benefits of the CALL-R functionality for CALL-R
servers (simplified parameter assignment)
OPC Server
(Data Access) • Corresponds to Data Access 2.05a specifica-
tion (reading/writing of online values).
• Is to be started as a manager just like other
drivers.
• The provided DPEs (server -> client) can be
easily and quickly defined via data point
groups.
• DPEs can be declared as readable (read-only
access is permitted; Group OPCRead) or as
writable items (Group OPCWrite).
Clients can browse the WinCC OA OPC Server
hierarchically.
OPC Alarms & Events OPC Alarms & Events (abbreviated to OPC A&E)
is, in addition to Data Access, a further standard
for performing central alarm management on a
cross-vendor basis. OPC A&E is used to ensure
the link to other control systems and the display
of alarms/events in a hierarchical system.
OPC UA
(Unified Architecture) • The OPC UA client supports the OPC UA stan-
dards Data Access and Alarms & Conditions.
The OPC UA Server supports the OPC UA stan-
dards Data Access and Alarms & Conditions.
Modbus TCP Modbus/TCP is based on the serial Modbus
protocol, which was adapted for TCP/IP.
The Modbus/TCP driver can be used
simultaneously for Modbus/TCP or UNICOS.
Serial: RK512/3964R Is used for interfacing a PLC via the 3964R/
RK512 protocol
Cerberus Cerberus is a fire, intrusion and gas alarm sys-
tem. The Cerberus driver guarantees communi-
cation to and from the central fire alarm systems
and building security facilities in the event a fire,
gas or intruder alarm.
SSI Is used for the interfacing of SAT remote control
systems. The data is exchanged via the LAN
(Ethernet, IEEE 802.3); the frame formats used
are the SSI formats defined by SAT. The SK 1703
telecontrol components with a suitable commu-
nication card (KE/ET) are supported.
IEC 60870-5-101, -104 IEC drivers are standardized telecontrol drivers
that can process proprietary frames. IEC stands
for International Electrotechnical Commission,
the international standardization committee for
electrical engineering.
• IEC 60870-5-104 for data exchange via TCP/IP
• IEC 60870-5-101 for serial connection
DNP3 The DNP3 (Distributed Network Protocol 3)
driver is an open, rugged and modern protocol
which exhibits characteristics and strengths sim-
ilar to the IEC driver. The transfer of any number
of frames with different data types takes place
between the WinCC OA System (Master) and the
remote stations (Slave).
SINAUT SINAUT (SIemens Network AUTomation) is a
communication protocol for automated monitor-
ing and control of remote process stations on the
basis of SIMATIC S7. Communication takes
place via TCP/IP.
SNMP Manager & Agent SNMP (Simple Network Management Protocol)
is a protocol for monitoring network elements
(servers, workstations, routers, switches, hubs,
etc.) and their functions.
SNMP Manager supports SNMP V1, V2, and V3
• SNMP Agent supports SNMP V1 and V2
BACnet over IP – driver BACnet (Building Automation and Control Net-
works) is a standardized protocol for building
automation and has been set by the ASHRAE
(American Society of Heating, Refrigerating and
Air-conditioning Engineers) as a guideline to pro-
vide a uniform and cross-company standard for
data communication within and between build-
ing automation systems.
The BACnet Standard 2004 is supported in
accordance with the PIC list (see product docu-
mentation)
Dynamic Logic – driver The Dynamic Logic driver communicates
with different Dynamic Logic devices via the
"FSK outstation protocol".
Applicom General
Interface Applicom is, among other things, a manufacturer
of I/O cards and software tools, with a wide
range of applications in automation engineering.
The Applicom products are compatible with
many common fieldbus systems and communi-
cations components.
Further drivers on request or via C++ API
Protocol Description
ST80_2013_EN_Kap04.book Seite 150 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture
4/151
Siemens ST 80 / ST PC · 2013
Technical specifications
1)
For actual use in plants, the hardware requirements are largely dependent
on the project size and the dynamic response of the process variables.
Whenever possible, use rugged, high-quality hardware with corresponding
functionalities such as redundant power supply units or RAID hard disks.
WinCC OA supports dual and multi-processor mode and benefits signifi-
cantly from the fact that each WinCC OA Manager can be assigned to one
processor core as a system process. At the same time, however, it is
important that the individual cores offer the highest possible performance
(high clocking), since load-critical core processes such as the event
manager run on exactly one core (for this reason, multi-core machines with
low-clocked cores are unsuitable for WinCC OA). As for RAM, CPU and
HDD, the usual rule applies: more is better
2)
System requirements generally only refer to WinCC OA Version 3.11 under
the supported versions of the Windows and Linux operating systems
3)
A precondition for the minimum requirement is that the operating system
used does not have any greater requirements itself
4)
With a large system it is essential that the system permits not only the
highest data point numbers but also a high dynamic response
WinCC OA is ideally suited for use in very large distributed
systems. The optimum design of such systems demands corre-
sponding system knowledge of WinCC OA. Due to the event-
oriented processing, individual design parameters can be
increased or reduced as necessary in actual applications.
1)
Dependent on the available storage space
2)
Dependent on the system configuration and the system load (due to the
event-oriented architecture, the system load is essentially determined by
the change rates of the values to be processed)
3)
By means of high-performance hardware configuration (one archiving
cluster and approx. 120 distributed systems that archive parallel values in
the cluster): 200,000 archived value changes per second
4)
Physical limit: <2048, in practice systems have already been implemented
with up to 550 distributed systems
5)
Physical limit: < 244 clients per server, recommended: max. 100 clients per
server
Type SIMATIC WinCC Open Architecture V3.11
Operating system Windows 8 Enterprise (64-bit)
• Windows 7 Ultimate/Enterprise/Professional
SP1 (32/64-bit)
• Windows XP SP2/SP3 (32-bit)
• Windows Server 2008 R2 (64-bit)
• Red Hat Linux 5 (32/64-bit)
• OpenSuse 12.1 (32/64-bit)
• Sun Solaris 10 SPARC (32-bit)
• Sun Solaris 10 x86 (64-bit)
• VMWare ESXi Version 4.0.0 & 5.0.0
Note:
Native 64-bit support on 64-bit systems
PC hardware requirements
1)
Processor type Intel Pentium or equivalent
Minimum Intel Pentium IV 1.6 GHz (or better)
2)3)
Recommended Client: Intel Pentium IV/Core2/i3, 2 GHz
2)3)
• Server: Intel Core i3 CPU Dual, 3 GHz
2)
Server large system
4)
: Intel(R) Core(TM) i5/i7
CPU Dual / Quad, 3 GHz
2)3)
RAM
Minimum 2 GB
2)
Recommended Client: 2 GB
2)3)
• Server: 8 GB
2)3)
• Server large system: 16 GB
2)
Hard disk
(available memory for
installation)
Minimum HD with 800 MB available
2)
Recommended Server large system with local logging:
SCSI LVD Controller, WIDE SCSI / LVD HDD
or comparable storage system with at least
500 MB of available space
2)
Screen and graphics card
(TrueColor)
Minimum 1024 x 768
2)
Recommended 1280 x 1024
2)
Mouse and keyboard Mouse, keyboard
DVD drive for software installation
Local power user rights • for installation
• for operation
Type SIMATIC WinCC Open Architecture
Functionality/quantity
structure
Number of messages 150,000
2)
Message text
(number of characters) System-limited
1)
Message archive System-limited
1)
Process values per mes-
sage 1 process value + up to 32 alarm associated
values per message
Constant load of messages,
max. 500/s
2)
Message burst, max. 15,000/10 s every 5 min
2)
Archives
Archive data points Max. 250,000 per server
2)
Archive types < 20 parallel logs, different retention period for
each log
Data storage format Oracle or file system
Measured values per sec-
ond, max. Server/single-user station: 7,000/s
2) 3)
User archive
Archives System-limited
1)
Type SIMATIC WinCC Open Architecture
Table size System-limited by ORACLE database
Graphics system
Number of screens System-limited
1)
Number of objects per
screen System-limited
1)
Number of controllable
fields per screen System-limited
1)
PowerTags < 750,000 per server
2)
User administration
User accounts < 4096
Configuration languages 2 (De, En)
Runtime languages 40 (of which 8 Asian)
Multi-user system
Server < 2048
2) 4)
Number of clients < 244 per server
2) 5)
ST80_2013_EN_Kap04.book Seite 151 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture
4/152 Siemens ST 80 / ST PC · 2013
4
Ordering data
Order No. Order No.
SIMATIC WinCC
Open Architecture
system software V3.11
WinCC OA core components
WinCC OA Server
Language/script versions: De, En;
with license for:
WinCC OA single-user station
500 I/O V3.11 6AV6351-1HA31-1AA0
License for single-user station with
up to 500 I/Os of any type (bit, inte-
ger), alerting, extended trend, his-
torical recording, not expandable to
more than one operator station, not
expandable by means of add-ons,
including S7 driver, OPC client,
OPC server, and OPC UA client.
WinCC OA Server I/O V3.11
License for server (without operator
station licenses), alerting, extended
trend, historical recording,
including S7 driver, OPC client,
OPC server, and OPC UA client.
WinCC OA Server 1,000 I/O V3.11
with a max. of 1,000 I/Os of any
type
6AV6351-1HB31-1AA0
WinCC OA Server 3,000 I/O V3.11
with a maximum of 3,000 I/Os of
any type
6AV6351-1HC31-1AA0
WinCC OA Server 5,000 I/O V3.11
with a max. of 5,000 I/Os of any
type
6AV6351-1HD31-1AA0
WinCC OA Server 10,000 I/O
V3.11
with a max. of 10,000 I/Os of any
type
6AV6351-1HE31-1AA0
WinCC OA Server 15,000 I/O
V3.11
with a max. of 15,000 I/Os of any
type
6AV6351-1HF31-1AA0
WinCC OA Server 25,000 I/O
V3.11
with a max. of 25,000 I/Os of any
type
6AV6351-1HG31-1AA0
WinCC OA Server 50,000 I/O
V3.11
with a max. of 50,000 I/Os of any
type
6AV6351-1HH31-1AA0
WinCC OA Server 75,000 I/O
V3.11
with a max. of 75,000 I/Os of any
type
6AV6351-1HJ31-1AA0
WinCC OA Server 100,000 I/O
V3.11
with a max. of 100,000 I/Os of any
type
6AV6351-1HK31-1AA0
WinCC OA Server 150,000 I/O
V3.11
with a max. of 150,000 I/Os of any
type
6AV6351-1HL31-1AA0
WinCC OA Server 200,000 I/O
V3.11
with a maximum of 200,000 I/Os of
any type
6AV6351-1HM31-1AA0
WinCC OA Server 250,000 I/O
V3.11
with a maximum of 250,000 I/Os of
any type
6AV6351-1HN31-1AA0
WinCC OA Server unlimited V3.11 6AV6351-1HP31-1AA0
License for server and one single-
user station (expandable to several
operator stations by means of cli-
ents) with unlimited number of I/O,
alerting, extended trend, historical
recording, including S7 driver,
OPC client, OPC server, and
OPC UA client.
WinCC OA Dongle V3.11 6AV6351-1AH31-1AA0
Hardware dongle on the USB port
for operation with a hardware-inde-
pendent license attached to the
dongle, which can also extend the
hardware-linked license of the oper-
ator station or server on a temporary
basis.
WinCC OA on data medium 6AV6351-1AX31-1AA0
WinCC OA Software DVD – current
version on disk
WinCC OA Client floating
Language/script versions: De, En;
with license for:
WinCC OA Client V3.11 6AV6351-1CP31-1AA0
Additional operator station license
with all server operator station
functionalities.
The client license can be installed
on more than one PC – only the
number of simultaneously active
clients is counted.
WinCC OA Web User Interface
Language versions: De, En; with
license for:
WinCC OA Web Client V3.11 6AV6351-1DP31-1AA0
Web client license for WinCC OA
Server. Only the number of simulta-
neously active web clients is
counted.
ST80_2013_EN_Kap04.book Seite 152 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture
4/153
Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
WinCC OA Ultralight Client
WinCC OA Ultralight PC Client
Licenses for one or several ultralight
clients running on a laptop or PC.
Only the number of simultaneously
active ultralight clients is counted.
Please note restrictions of the ultra-
light client according to the online
help.
WinCC OA 1 Ultralight PC Client
License for one ultralight client 6AV6351-1JA31-1AA0
WinCC OA 3 Ultralight PC Clients
License for 3 ultralight clients 6AV6351-1JB31-1AA0
WinCC OA 10 Ultralight
PC Clients
License for 10 ultralight clients
6AV6351-1JC31-1AA0
WinCC OA Ultralight Mobile Client 6AV6351-1JG31-1AA0
Licenses for one or several ultralight
clients running on a smartphone or
tablet PC. Only the number of simul-
taneously active ultralight clients is
counted. Please note restrictions of
the ultralight client according to the
online help.
WinCC OA 1 Ultralight Mobile
Client
License for one ultralight client
6AV6351-1JG31-1AA0
WinCC OA 3 Ultralight Mobile
Clients
License for 3 ultralight clients
6AV6351-1JH31-1AA0
WinCC OA 10 Ultralight Mobile
Clients
License for 10 ultralight clients
6AV6351-1JJ31-1AA0
WinCC OA parameter assignment
and development license
WinCC OA Para for single-user
station V3.11 6AV6351-1EA31-1AA0
Parameterization and development
license for single-user station,
graphic editor with symbol catalog
and ActiveX Controls, user-friendly
script development language, alert-
ing, extended trend, historical
recording. Requires a correspond-
ing single-user station license.
WinCC OA Para V3.11 6AV6351-1EP31-1AA0
Parameterization and development
license for server, graphic editor
with symbol catalog and ActiveX
Controls, user-friendly script devel-
opment language, alerting,
extended trend, historical recording.
Requires corresponding server
license.
WinCC OA ETool V3.11 6AV6351-1EJ31-1AA0
License for the use of the integrated
WinCC OA ETool engineering envi-
ronment, including the object library
S7-BaseLib.
Intellectual property right owner:
Siemens AG.
WinCC OA API interface
gen. V3.11 6AV6351-1EK31-1AA0
Application programming interface
for the integration of customer-spe-
cific managers or drivers. One
license is required for each develop-
ment workstation. We strongly rec-
ommend the participation in a
Certified WinCC OA Developer
Workshop when ordering this
product for the first time.
WinCC OA Custom Driver V3.11 6AV6351-1EL31-1AA0
Extends a WinCC OA server license
with the option of communication
with a customer-specific driver. One
license is required for each cus-
tomer-specific driver.
WinCC OA Custom Manager V3.11 6AV6351-1EM31-1AA0
Extends a WinCC OA server license
with the option of communicating
with a customer-specific manager.
One license is required for each
customer-specific manager
WinCC OA redundancy
WinCC OA Redundancy V3.11 6AV6351-1FP31-1AA0
Extends a WinCC OA Server with
the option of bumpless switchover
to a hot standby partner.
WinCC OA distributed systems
WinCC OA distributed systems
V3.11 6AV6351-1GP31-1AA0
Extends a WinCC OA Server to
include the Multiserver option.
WinCC OA Disaster Recovery
System
WinCC OA Disaster Recovery
Center V3.11 6AV6352-1AA31-1AA0
Allows the configuration of a remote
backup control center. A disaster
recovery center comprises two dis-
tributed systems. Each system can
be redundant or non-redundant.
Requires Oracle databases and
RDB. Refer to the online help for
example configurations. Each
server in the Disaster Recovery
System requires one WinCC OA
Disaster Recovery Center option.
ST80_2013_EN_Kap04.book Seite 153 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture
4/154 Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
4
More information
Further information can be found in the Internet at:
http://www.siemens.com/wincc-open-architecture
SIMATIC WinCC Open Architecture
V3.11 communication
WinCC OA TLS driver 6AV6352-1BA31-1AA0
Driver in accordance with TLS regula-
tions in connection with Siemens
Commbox (see separate data sheet).
WinCC OA Teleperm M 6AV6352-1BB31-1AA0
Driver for Teleperm M Bus C275
(requires an Acotex Comm Box)
WinCC OA S7 TCP/IP driver 6AV6352-1BC31-1AA0
TCP/IP for Siemens Industrial Ethernet
WinCC OA Modbus TCP/IP driver 6AV6352-1BD31-1AA0
TCP/IP for Schneider Modbus
WinCC OA Modbus serial 6AV6352-1BE31-1AA0
Serial driver for Schneider Modbus
WinCC OA SSI driver 6AV6352-1BF31-1AA0
Driver for SAT telecontrol components
WinCC OA SNMP 6AV6352-1BG31-1AA0
Driver SNMP – network monitoring
(V2&V3)
WinCC OA IEC 104 6AV6352-1BH31-1AA0
Driver IEC 60870-5-104
WinCC OA IEC 101 6AV6352-1BJ31-1AA0
Driver IEC 60870-5-101
WinCC OA DNP3 10 devices 6AV6352-1BK31-1AA0
Driver DNP3 for connecting
up to 10 DNP3 devices
WinCC OA DNP3 25 devices 6AV6352-1BL31-1AA0
Driver DNP3 for connecting
up to 25 DNP3 devices
WinCC OA DNP3 50 devices 6AV6352-1BM31-1AA0
Driver DNP3 for connecting
up to 50 DNP3 devices
WinCC OA DNP3 250 devices 6AV6352-1BN31-1AA0
Driver DNP3 for connecting
up to 250 DNP3 devices
WinCC OA DNP3 unlimited 6AV6352-1BP31-1AA0
Driver DNP3 – unlimited license
WinCC OA SINAUT 10 devices 6AV6352-1BQ31-1AA0
SINAUT driver for connecting
up to 10 controllers
WinCC OA SINAUT 25 devices 6AV6352-1BR31-1AA0
SINAUT driver for connecting
up to 25 controllers
WinCC OA SINAUT 50 devices 6AV6352-1BS31-1AA0
SINAUT driver for connecting
up to 50 controllers
WinCC OA SINAUT 250 devices 6AV6352-1BT31-1AA0
SINAUT driver for connecting
up to 250 controllers
WinCC OA SINAUT unlimited 6AV6352-1BU31-1AA0
SINAUT driver – unlimited license
WinCC OA RK512 6AV6352-1CA31-1AA0
Driver for connection
via 3964R / RK512 protocol
WinCC OA PROFIBUS DP 6AV6352-1CB31-1AA0
Driver PROFIBUS DP,
an Applicom card is required
WinCC OA PROFIBUS S7 6AV6352-1CC31-1AA0
Driver PROFIBUS S7 + MPI,
an Applicom card is required
WinCC OA Omron FINS TCP-IP 6AV6352-1CE31-1AA0
Driver Omron FINSTCP-IP,
an Applicom card is required
WinCC OA GE Fanuc SRTP 6AV6352-1CF31-1AA0
Driver GE Fanuc SRTP,
an Applicom card is required
WinCC OA Allen Bradley Ethernet/IP 6AV6352-1CG31-1AA0
Driver Allen Bradley Ethernet/IP,
an Applicom card is required.
WinCC OA Cerberus 6AV6352-1CH31-1AA0
Driver for connection with the Siemens
DMS7000 / Cerberus fire alarm sys-
tem. Communication is implemented
via the C-Bus (Cer-Ban) using the
serial interface RS 232 (MK 7022).
WinCC OA OPC UA Server 6AV6352-1CJ31-1AA0
Driver for OPC UA DA and
OPC UA AC Server
ST80_2013_EN_Kap04.book Seite 154 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture Add-ons
4/155
Siemens ST 80 / ST PC · 2013
Overview
SIMATIC WinCC Open Architecture is a SCADA system for
visualizing and operating processes, production flows,
machines and plants in all industrial sectors.
SIMATIC WinCC OA is built consistently on object-oriented
structures. The rigorous and well-considered use of object-
oriented structures, from process images to the database, help
to improve engineering costs for SIMATIC WinCC OA customers.
Distributed systems enable the connection of up to 2048 auton-
omous SIMATIC WinCC Open Architecture systems via one
network. Each subsystem can be configured either as single-
user or multi-user system, each of which may be redundant or
non-redundant.
Current version: SIMATIC WinCC Open Architecture V3.11
Runs on:
- Windows 8 Enterprise (64-bit)
- Windows 7 Ultimate/Enterprise/Professional SP1 (32/64-bit)
- Windows XP SP2/SP3 (32-bit)
- Windows Server 2008 R2 (64-bit)
- Red Hat Linux 5 (32/64-bit)
- OpenSuse 12.1 (32/64-bit)
- Sun Solaris 10 SPARC (32-bit)
- Sun Solaris 10 x86 (64-bit)
- VMWare ESXi Version 4.0.0 & 5.0.0
Note:
Native 64-bit support on 64-bit systems.
Function
SIMATIC WinCC Open Architecture add-ons
The universal WinCC Open Architecture basic software is the
basis for modular expansions. These functional expansions are
available in the form of WinCC Open Architecture add-ons.
Distributed systems with WinCC OA
WinCC OA
Server (multi-user system)
WinCC OA
Server
(stand alone
system)
Operational station
Operational station
Operational station
Operational station
Operational station
WinCC OA System communication TCP
Field devices
or other connected systems
System 3 System 2
System 1
WinCC OA
Server
(redundant)
MODBUS (TCP)
S7 Industrial Ethernet (TCP)
OPC UA (TCP)
G_ST80_XX_00480
ST80_2013_EN_Kap04.book Seite 155 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture Add-ons
4/156 Siemens ST 80 / ST PC · 2013
Function (continued)
4
Add-ons Task
ETool The engineering tool ETool offers significant
benefits in engineering in the case of combined
WinCC OA and SIMATIC STEP7/PCS7 projects. It
provides a user-friendly engineering environment
that permits easy, integrated and fast configuration
on the basis of the WinCC OA mass parameteriza-
tion.
BACnet BACnet provides an integrated BACnet-compliant
online/offline engineering solution for building
automation technology, including object library.
Designed for heating, ventilation and air-condition-
ing, lighting control and safety systems.
S7 AdvancedLib
object library The S7 AdvancedLib (AdvS7) is an industry-inde-
pendent object library that permits the use and
visualization of objects from the process control
system (e.g.: drives, valves, regulators, motors,
etc.) in a project with WinCC OA and S7. In addi-
tion to the WinCC OA and AdvS7 license, the use
of S7 AdvancedLib requires the use of the relevant
library on the SIMATIC side.
Maintenance package Includes the following functions: Operating hours
counter, operating cycle counter and maintenance
log.
Scheduler Permits the creation, parameterization and man-
agement of time programs that allow the time and
event-driven triggering of specific actions.
Recipes WinCC OA recipes allow setpoints or commands
for certain data point elements to be sent simulta-
neously. Based on "recipe types", which define the
quantity of the assigned data point elements, reci-
pes are created that send their values to the data
point elements upon activation.
GIS Viewer With the help of this viewer, standardized cards of
a geo-information system (GIS) can be fully inte-
grated in WinCC OA. Furthermore, it is possible to
display all WinCC OA objects in the cards.
Excel report Powerful report generator directly in Microsoft
Excel. Templates can be created easily and
directly in Excel. If a report has to be created over
a defined period of time, the system accesses the
template and automatically completes it with data
from the WinCC OA process database. Reports
can also be created, printed and saved on a time-
controlled basis, without any need for user access.
The Excel Report fully supports compression
structures (AC - archive compression) of
WinCC OA.
Communication
Center Stands for modern alarm management/remote
alerting and communication using the latest stan-
dards and various media. The Communication
Center creates synergies by using the various
interfaces for remote alerting via the control
system.
Text message and email media are covered with
the Communication Center.
Video
(see figure below) Enables the integration of a video management
system in WinCC OA. Through the combination of
SCADA and video monitoring in one system, the
costs for separate video interfaces and the addi-
tional expense of maintenance and operation can
be saved, and the period of training for operating
personnel can also be reduced.
HTTP server For displaying WinCC OA data via Intranet and
Web.
Authentication
via Kerberos A WinCC OA system can be exposed to a variety
of attacks. An unauthorized WinCC OA System
could set up a connection to the distribution man-
ager or hackers could try to manipulate WinCC OA
messages. Secure authentication has been devel-
oped to prevent such attacks. The authentication
based on Kerberos enables each WinCC OA com-
ponent to verify the identity of another component.
WinCC OA servers can verify the identity of the cli-
ents and clients can verify the identity of the serv-
ers. In addition, Kerberos ensures that messages
are not modified during their transmission (cap-
ture-replay attacks are prevented). Furthermore,
it is also possible to send messages in encrypted
form.
AMS (Advanced
Maintenance Suite) For the effective planning, administration, imple-
mentation and monitoring of maintenance work
and faults. The processes are evaluated by means
of statistics and reports are communicated.
Web client From a technical standpoint, the WinCC OA Web
Client is a plug-in that is downloaded via the web
browser (which is used on the client computer)
and a WinCC OA UI Manager is then displayed
embedded in the HTML page. No WinCC OA
installation on the client computer is required,
except for the required web client plug-ins.
Ultralight client A "thin client" that supports access to the plant via
a mobile device (such as a cell phone or tablet) in
addition to a PC workstation. Access is possible
via a standard Web browser using native Web
technologies (Javascript, SVG) without the need
for any additional installations. It provides a user
interface even at those locations with Internet con-
nections offering very low bandwidth, as only the
most essential data is transferred.
Disaster Recovery
System
(see figure below)
This system expands the simple redundancy to
include a second redundant system, to which the
system can switch over in the event of a fault
(e.g. fire or explosion in the building of the primary
system). By means of this additional local redun-
dancy, the highest level of system stability is
obtained.
Add-ons Task
ST80_2013_EN_Kap04.book Seite 156 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture Add-ons
4/157
Siemens ST 80 / ST PC · 2013
Function (continued)
Network topology Video
Disaster Recovery System architecture with WinCC OA
Video workstation
Control monitor
(optional)
Operator keyboard
mouse
joystick Video monitor 1
Video monitor 2
(optional)
TCP/IP
connection
Monitor wall
(monitors 2 ... n)
Cameras or
crossbars
Network
video recorder
Control commands
Control of monitor wall via POSA protocol
Monitor 1
Encoder
Decoder
WinCC OA
Server
G_ST80_XX_00481
Secondary Server System (SSS)Primary Server System (PSS)
Database in
Oracle Cluster
Operating Interface
with one or two
interfaces
Field device or other
connected systems like
for example OPC UA
WinCC OA
Hot-Standby
System
WinCC OA
Hot-Standby
System
WinCC OA
active
Server (A)
WinCC OA
passive
Server (B)
WinCC OA
active
Server (C)
WinCC OA
passive
Server (D)
Database in
Oracle Cluster
G_ST80_XX_00482
ST80_2013_EN_Kap04.book Seite 157 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture Add-ons
4/158 Siemens ST 80 / ST PC · 2013
4
Ordering data
Order No. Order No.
SIMATIC WinCC
Open Architecture add-ons
WinCC OA BACnet driver +
diagnostics 6AV6352-1DA31-1AA0
Extends a WinCC OA Server to include
a license for using the WinCC OA
BACnet online engineering environ-
ment consisting of WinCC OA BACnet
driver, WinCC OA BACnet object
library including faceplates, and
WinCC OA BACnet browser
(max. 5,000 objects per server).
WinCC OA BACnet Engineering 6AV6352-1DB31-1AA0
Extends a WinCC OA Server to include
a license for using the WinCC OA
BACnet engineering environment con-
sisting of WinCC OA BACnet browser,
WinCC OA EDE-Tool + EDE file inter-
face (requires the WinCC OA engi-
neering license) (max. 5,000 objects
per server).
WinCC OA GIS 6AV6352-1DC31-1AA0
GIS viewer for displaying ESRI Shapes
Files. One license is required for each
UI. Can be used in WinCC OA Client
and Web Client. Maps are not
included. Dynamization performed
using Ctrl scripting.
WinCC OA S7 AdvancedLib 6AV6352-1DD31-1AA0
Runtime license for using the object
library WinCC OA S7 AdvancedLib,
coordinated with the SIMATIC object
library also supplied, which is free of
charge until revoked. License required
for each server.
WinCC OA Maintenance 6AV6352-1DE31-1AA0
Maintenance management for record-
ing operating hours, switching cycles,
alarm handling and notepad function.
License required for each server.
WinCC OA Scheduler 6AV6352-1DF31-1AA0
Daily, weekly and monthly program, as
well as individual non-periodic events
with consideration of public holidays,
assignment of priority and override
function. License required for each
server.
WinCC OA Recipe 6AV6352-1DG31-1AA0
Creation of any recipe types and reci-
pes, acceptance of current process
values as recipe, activation/download
to data points, import and export
(Microsoft Excel). License required for
each server.
WinCC OA RDB 6AV6352-1DH31-1AA0
RDB Oracle connection for WinCC OA
Server S-UL. Oracle licenses are not
included. License required for each
server.
Solution Frameworks
WinCC OA PMS 6AV6352-1EA31-1AA0
Application framework for the imple-
mentation of production management
systems. The framework offers
functions for recording and evaluating
production and batch-related quality
data. This item is not available as a
product but only in combination with
consulting and additional testing
overhead.
WinCC OA topology package 6AV6352-1EB31-1AA0
The topology package is an applica-
tion framework enabling the topologi-
cal coloring of network views.
A qualitative statement is made
regarding which parts of a network are
directly connected to which infeed
units in a connection established by
switching elements. Only available in
combination with consulting and addi-
tional testing overhead.
WinCC OA ACAS 6AV6352-1EC31-1AA0
WinCC OA Advanced Command
Authority Suite framework for manag-
ing and visualizing authority settings.
The license includes the management
panel and panel expansions for alarm,
horn and acknowledgement func-
tions. This item is not available as a
product but only in combination with
consulting and additional testing over-
head.
Excel report
WinCC OA Report 1 UI 6AV6352-1FA31-1AA0
Expands a WinCC OA Server
by 1 active Excel report process;
Microsoft Excel is not included.
WinCC OA Report 2 UI 6AV6352-1FB31-1AA0
Expands a WinCC OA Server
by 2 parallel active Excel report
processes; Microsoft Excel is not
included.
WinCC OA Report 5 UI 6AV6352-1FC31-1AA0
Expands a WinCC OA Server
by 5 parallel active Excel report
processes; Microsoft Excel is not
included.
WinCC OA Report 10 UI 6AV6352-1FD31-1AA0
Expands a WinCC OA Server
by 10 parallel active Excel report
processes; Microsoft Excel is not
included.
ST80_2013_EN_Kap04.book Seite 158 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture Add-ons
4/159
Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
Communication Center
WinCC OA CommCenter 1 6AV6352-1GA31-1AA0
Basic package for 25 alarms. Output
as text message or e-mail is possible.
Price per WinCC OA Server.
WinCC OA CommCenter 2 6AV6352-1GB31-1AA0
Basic package for 250 alarms. Output
as text message or e-mail is possible.
Price per WinCC OA Server.
WinCC OA CommCenter 3 6AV6352-1GC31-1AA0
Basic package for 2,500 alarms. Out-
put as text message or e-mail is possi-
ble. Price per WinCC OA Server.
WinCC OA CommCenter 4 6AV6352-1GD31-1AA0
Basic package for unlimited alarms.
Output as text message or e-mail is
possible. Price per WinCC OA Server.
Video management
WinCC OA Video Light 6AV6352-1HA31-1AA0
Including 4 streams. Possible video
operator station configuration:
1 x quad image or 2 dual images or
4 single images. Not expandable with
further streams, redundancy not possi-
ble.
WinCC OA Video Basic 6AV6352-1HB31-1AA0
Including 7 streams. Possible video
operator station configuration: Display
in quad, dual or single images.
Expandable by additional streams,
redundancy is possible. One license is
required for each WinCC OA Server.
WinCC OA Video Extension
5 Streams 6AV6352-1HC31-1AA0
Extends WinCC OA Video Basic
by 5 streams
WinCC OA Video Extension
7 Streams 6AV6352-1HD31-1AA0
Extends WinCC OA Video Basic
by 7 streams
WinCC OA Video Extension
32 Streams 6AV6352-1HE31-1AA0
Extends WinCC OA Video Basic
by 32 streams
WinCC OA Video Extension
128 Streams 6AV6352-1HF31-1AA0
Extends WinCC OA Video Basic by
128 streams
WinCC OA Video Extension
256 Streams 6AV6352-1HG31-1AA0
Extends WinCC OA Video Basic
by 256 streams
WinCC OA Video Extension
512 Streams 6AV6352-1HH31-1AA0
Extends WinCC OA Video Basic
by 512 streams
WinCC OA video driver SNK
RS485 eneo 6AV6352-1HJ31-1AA0
Driver for controlling eneo pan-tilt
cameras. One license is required for
each WinCC OA Server.
WinCC OA video driver RS 485TVI 6AV6352-1HK31-1AA0
Driver for controlling TVI pan-tilt
cameras. One license is required for
each WinCC OA Server.
WinCC OA video driver SNK
RS485 Funkwerk 6AV6352-1HL31-1AA0
Driver for controlling Funkwerk pan-tilt
cameras. One license is required for
each WinCC OA Server.
WinCC OA video driver SNK
RS485 Globe 6AV6352-1HM31-1AA0
Driver for controlling Globe pan-tilt
cameras.
One license is required for each
WinCC OA Server.
WinCC OA video driver SNK
development 6AV6352-1HN31-1AA0
Driver development for controlling
pan-tilt cameras
WinCC OA video driver
for cameras with RCP+ and H264 6AV6352-1HP31-1AA0
Drivers for controlling cameras with
RCP+ and H264.
One license is required for each
WinCC OA Server.
WinCC OA video driver dev. 6AV6352-1HQ31-1AA0
Driver development for controlling
decoder/encoder/host protocols
WinCC OA video driver Bosch
IntKey 6AV6352-1HR31-1AA0
Driver for controlling Bosch IntKey
console controller.
One license is required per server
WinCC OA Video driver develop-
ment for console controllers 6AV6352-1HS31-1AA0
Driver development for controlling
console controllers
WinCC OA video driver Bosch VRM
(NVR) 6AV6352-1HT31-1AA0
Drivers for controlling Bosch video
recording equipment / NVR.
One license is required per server
WinCC OA video driver develop-
ment for recording equipment / NVR 6AV6352-1HU31-1AA0
Driver development for video recorder
equipment / NVR
HTTP server
WinCC OA HTTP Server 6AV6352-1KA31-1AA0
Forwarding of alarms, events and
WinCC OA information to the Internet
in HTML format including 1 HTTP con-
nection.
WinCC OA HTTP Server Extension5 6AV6352-1KB31-1AA0
Extends the WinCC OA HTTP server
by 5 HTTP connections.
WinCC OA HTTP Server
Extension10 6AV6352-1KC31-1AA0
Extends the WinCC OA HTTP server
by 10 HTTP connections.
WinCC OA HTTP Server
Extension25 6AV6352-1KD31-1AA0
Extends the WinCC OA HTTP server
by 25 HTTP connections.
ST80_2013_EN_Kap04.book Seite 159 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SCADA System SIMATIC WinCC Open Architecture
SIMATIC WinCC Open Architecture Add-ons
4/160 Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
4
1)
The basic price also includes the AMS Reports packages.
2)
AMS importer as well as 1 day of consulting for initial design by
ETM Consultants (excluding travel expenses) and 5 hours of telephone
support within 3 months after delivery.
3)
AMS Reports and AMS Importer, and 1 day of consulting for initial concep-
tualization by ETM consultants (not incl. travel costs). This license does not
include any support and cannot be expanded or extended.
More information
Additional information is available on the Internet at:
http://www.siemens.com/wincc-open-architecture
Kerberos
WinCC OA Secure 6AV6352-1LA31-1AA0
Extends a WinCC OA Server to include
protection by Kerberos.
Each WinCC OA Server requires a
separate WinCC OA Secure license.
AMS (Advanced Maintenance Suite)
AMS Starter Package 20A/E 6AV6352-1MA31-1AA0
This fully functional trial license
valid for 90 days includes the
AMS application as well as up to
20 A/E = 20 checklists assigned to
alarm/event DP.
1)2)3)
AMS Entry 20 A/E 6AV6352-1MB31-1AA0
The license includes the
AMS application as well as up to
20 A/E = 20 checklists assigned to
alarm/event DP.
1)2)3)
AMS Small 100 A/E 6AV6352-1MC31-1AA0
The license includes the
AMS application as well as
up to 100 A/E = 100 checklists
assigned to alarm/event DP.
1)2)3)
AMS Medium 1,000 A/E 6AV6352-1MD31-1AA0
The license includes the
AMS application as well as
up to 1,000 A/E = 1,000 checklists
assigned to alarm/event DP.
1)2)3)
AMS Large 5,000 A/E 6AV6352-1ME31-1AA0
The license includes the
AMS application as well as
up to 5,000 A/E = 5,000 checklists
assigned to alarm/event DP.
1)2)3)
AMS Upgrade Large 6AV6352-1MF31-1AA0
The license contains an upgrade of
the AMS Large 5,000 A/E license with
1,000 A/E = 1,000 checklists assigned
to alarm/event DP.
AMS UL A/E 6AV6352-1MG31-1AA0
The license includes the AMS applica-
tion as well as an unlimited number of
alarm/event DP checklist
assignments.
1)2)3)
AMS Client 2 UI 6AV6352-1MH31-1AA0
Operating station license for simulta-
neous use of no more than 2 parallel
client sessions. The client license can
be installed on more than one PC –
only the number of simultaneously
active clients is counted.
AMS Client 5 UI 6AV6352-1MJ31-1AA0
Operating station license for simulta-
neous use of no more than 5 parallel
client sessions. The client license can
be installed on more than one PC –
only the number of simultaneously
active clients is counted.
AMS Client 10 UI 6AV6352-1MK31-1AA0
Operating station license for simulta-
neous use of no more than 10 parallel
client sessions. The client license can
be installed on more than one PC –
only the number of simultaneously
active clients is counted.
ST80_2013_EN_Kap04.book Seite 160 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC ProAgent process diagnostics software
SIMATIC ProAgent
4/161
Siemens ST 80 / ST PC · 2013
Overview
Process error diagnostics software for quick and precise
diagnosis of faults/errors in plants and machines for
SIMATIC S7 and SIMATIC HMI
Standardized diagnostics concept for various
SIMATIC components:
optimum interaction of STEP 7 engineering tools and
SIMATIC HMI
Standardized user interface
Process error diagnostics with ProAgent for WinCC flexible /ProAgent
and with the STEP 7 engineering tools
Process error diagnostics with WinCC/ProAgent and the STEP 7
engineering tools
Benefits
Integral component of Totally Integrated Automation (TIA):
increases productivity, minimizes the engineering outlay,
reduces the lifecycle costs
• ProAgent:
- Provides optimum support for plant and machine personnel
in respect of troubleshooting and fault rectification
- Increases plant availability
- Reduces downtimes
No further configuration overhead for diagnostics functionality
Frees up PLC capacity with regard to memory and program
execution time
No special operator know-how is required thanks to clearly
comprehensible indication of the cause of error
Application
Increased productivity is being achieved more and more by
cutting costs.
In this context, the focus is increasingly on maintenance.
The emphasis here is on rectifying faults as quickly and
efficiently as possible.
Ideally, the operating personnel should also perform part of the
maintenance tasks. The operating personnel are on-site, they
are familiar with the procedures and can intervene quickly. This
saves time and reduces costs. It is precisely here that ProAgent
can assist operating personnel in identifying faults quickly, in
particular in the automotive and machine tool industries.
In the event of a process fault, process fault diagnostics with
SIMATIC ProAgent will provide information about the location
and cause of that fault and support personnel with trouble-
shooting.
The ProAgent solution has been optimized specifically for use
with SIMATIC S7-300/S7-400 and SIMATIC WinAC.
It can be used in combination with the S7-PDIAG, S7-GRAPH
and S7-HiGraph
1)
STEP 7 engineering tools. The ProAgent
option package features standard displays that are updated with
process-specific data during runtime.
1)
Process diagnostics with S7-HiGraph in combination with
TP/OP/MP 270/277, MP 370/377, and C7636 and PC RT systems.
G_ST80_XX_00367
67(3
3B 67  B ; ; B   
67(3
ST80_2013_EN_Kap04.book Seite 161 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC ProAgent process diagnostics software
SIMATIC ProAgent
4/162 Siemens ST 80 / ST PC · 2013
4
Function
Context-sensitive diagnostics initiation due to process error
message
Output of operands with symbols and comment
Switching is possible between LAD, STL and signal list
Supporting fault rectification with direct process access when
using the motion display
Output of the faulty operands directly in the message
including address, symbol and comment
1)
Consistency test in RT:
Inconsistent diagnostic units are marked with icons. This
permits quick locating of faults regarding configured data in
the commissioning phase.
Direct, unit-related entry point in the diagnostic display from
user displays by using ProAgent functions
Unit or message-related entry to STEP 7 (LAD/STL/FD editor,
S7-GRAPH, HW CONFIG (upon system error messages)),
supported fully automatically
2)
Unit or message-related entry to STEP 7),
supported fully automatically
3)
Graphic display of step sequences (overview display)
4)
1)
In combination with TP/OP/MP 270/277, MP 370/377, C7 636,
WinCC/ProAgent as of V6.0, and WinCC flexible /ProAgent
2)
WinCC/ProAgent as of V5.5 and as of WinCC flexible 2007 /ProAgent
on PC RT
3)
Only WinCC/ProAgent as of V5.5
4)
As of WinCC flexible 2007 /ProAgent, WinCC/ProAgent as of V5.6 in
combination with S7-GRAPH as of V5.1 (OCX is delivered as of
S7-GRAPH 5.1)
Standardized user interface with standard displays
Message display
Unit overview
Diagnostics detail display
Motion display
Sequencer operating display
The displayed image contents are related to the previously
selected units or messages. This means that the proper. context-
sensitive diagnostics display can be called up based on a
message or a selected technological unit.
Message display
All of the existing process messages are shown in the message
display. Context-sensitive branching to other diagnostic
displays is also possible with a selected message. The
operating personnel can also take the message directly from the
erroneous operands and react immediately without having to
perform any other operations on the HMI device. WinCC flexible
permits this function on the Windows CE-based devices
TP/OP/MP 270/277, MP 370/377, and on PC Runtime systems.
The function is available as of version 6.0 for WinCC/ProAgent.
Unit overview
The units overview displays all technological units and the
respective sub-units (system/machine components) in table
form. In this display, the user is able to recognize, for example,
which operating mode or which status the respective unit is in.
The operating mode can be changed by the user if required.
Faulty units are marked with attributes.
ST80_2013_EN_Kap04.book Seite 162 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC ProAgent process diagnostics software
SIMATIC ProAgent
4/163
Siemens ST 80 / ST PC · 2013
Function (continued)
Diagnostics detail display
The diagnostic detail display shows the faulty operands at the
time of origination of a process error. As an option, current status
information can also be displayed. The diagnostics results are
either displayed in a ladder diagram (LAD), statement list (STL),
or in a clearly arranged signal list overview. The output of the
operands depends on the display format with symbols and
comments from the S7 symbol table. Only the operands that
cause the fault are displayed and marked with a highlighted
attribute. Switching to a display that calls up the current status of
all operands in the controller is also possible.
Motion display
The motion display is used for supported fault rectification. Every
motion line contains a comment line that describes the motion
(e.g. x-axis), two actions for implementing the motion, response
concerning the actuation of a motion and information on the
respectively achieved end positions (max. 16).
The motion itself is controlled with softkeys on the side of
SIMATIC Panels and Multi Panels. For time-critical motions, the
actuation can be done directly through inputs of the controller
(depending on the capabilities of the target hardware:
24 V direct keys, DP direct keys via PROFIBUS).
Sequencer operating display
The sequencer operating display supports sequencer control.
This makes functions such as initializing and acknowledging
sequencers, activating/deactivating individual steps and
operating mode settings possible analog to the status/control in
S7-GRAPH.
The steps are output to a list with step number/name. Attributes
for identifying an active/faulty step give the operating personnel
an overview of the current status of the step sequence.
Sequencer diagnostic display
WinCC flexible/ProAgent and WinCC/ProAgent
1)
also offer
capabilities for graphic monitoring and sequencer diagnostics.
This gives the user the ability to monitor active/faulty steps as
well as the fault cause, e.g. faulty transition conditions, simulta-
neously on the HMI device.
1)
WinCC/ProAgent as of V5.6 in combination with S7-GRAPH as of V5.1
(OCX is delivered as of S7-GRAPH 5.1)
ST80_2013_EN_Kap04.book Seite 163 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC ProAgent process diagnostics software
SIMATIC ProAgent
4/164 Siemens ST 80 / ST PC · 2013
4
Technical specifications
WinCC/ProAgent WinCC flexible /ProAgent
Interfaces
Can be used in conjunction with
programmable controllers: SIMATIC S7:
S7-300/S7-400; WinAC SIMATIC S7:
S7-300/S7-400; WinAC
• Types of connection SIMATIC S7 Protocol Suite:
MPI, PROFIBUS DP, Industrial Ethernet, TCP/IP SIMATIC S7 Protocol Suite:
MPI, PROFIBUS DP,
PROFINET IO, Industrial Ethernet, TCP/IP
Display units
Standard images for: Standard displays for easy embedding in user displays,
example project for MP 377
Number of languages for
online language selection 3 (de/en/fr) 5 (de/en/fr/it/es)
Functionality
Modification of HMI diagnostics data
management in RT WinCC/ProAgent V6.0 and higher No
Unit overview Yes Yes
Message display Yes Yes
Sequencer operating display Yes Yes
Diagnostics detail display Yes Yes
Display
STL/LAD/signal list Yes/Yes/Yes Yes/Yes/Yes
Display of operands with symbol and
comment Yes Yes
Criteria analysis When fault occurs/current status/can be archived When fault occurs/current status
Motion display
Number of viewable
movements 6 6
• Directions of motion 2 2
Number of viewable
end positions per movement 16 16
Documentation
In electronic format de/en/fr; included in scope of delivery de/en/fr/it/es; included in scope of delivery
Requirements
HMI software WinCC V7.0 SP3
(ProAgent V7.0 SP3) WinCC flexible 2008
Operating system:
Configuration WinCC/ProAgent V7.0 + SP2:
Windows Professional SP3, Windows 7 (32 bit) Ultimate,
Business, and Enterprise
WinCC flexible /ProAgent 2008 + SP2:
Windows XP SP3,
Windows 7 Professional,
Ultimate, Enterprise
Operating system
Runtime WinCC/ProAgent V7.0 + SP2:
Windows XP Professional SP3,
Windows 7 (32 bit) Ultimate, Business and Enterprise,
Windows 2003 Server SP2, Windows 2008 Server SP2
WinCC flexible /ProAgent for SIMATIC Panels:
WinCC flexible /ProAgent for WinCC flexible Runtime:
Windows XP SP3,
Windows 7 Professional, Ultimate, Enterprise
STEP 7 V5.4 SP4 and higher V5.3 and higher
• S7-GRAPH V5.3 SP6 and higher V5.2 + SP3 and higher
•S7-PDIAG V5.3 SP3 and higher V5.1 and higher
• S7-HiGraph No V5.3 and higher
Type of delivery
(one license is required for each target
hardware)
CD-ROM / Runtime license Runtime license
ST80_2013_EN_Kap04.book Seite 164 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
SIMATIC ProAgent process diagnostics software
SIMATIC ProAgent
4/165
Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
1)
Not multi-station-capable
SIMATIC WinCC/ProAgent
Software option package for
process error diagnostics based
on S7 GRAPH V5 and higher and
S7 PDIAG V5 and higher;
functional enhancement for
SIMATIC WinCC;
electronic documentation in English,
French and German;
functions and standard screens for
use on a PC (resolution 1024 x 768
pixel) and Panel PC 577/677/
877 15" (resolution 1024 x 768 pixel)
in English, French and German,
Runtime license (single license)
WinCC version:
V7.0 SP3; for WinCC V7.0 SP3
1)
6AV6371-1DG07-0AX0
Upgrade
• to V7.0 SP3
1)
6AV6371-1DG07-0AX4
SIMATIC WinCC flexible /ProAgent
Software option package for pro-
cess error diagnostics based on
S7 PDIAG V5.1 and higher,
S7 GRAPH V5.2 + SP3 and higher;
S7 HiGRAPH V5.3 and higher.
Functional enhancement for
SIMATIC WinCC flexible; electronic
documentation in English, French,
German, Italian and Spanish
WinCC flexible /ProAgent
for SIMATIC Panels
Runtime license (Single License)
executable on TP/OP/MP 270/277,
Mobile Panel 277 and MP 370/377
6AV6618-7DB01-3AB0
WinCC flexible /ProAgent
for WinCC flexible Runtime
Runtime license (single license)
6AV6618-7DD01-3AB0
Documentation
(must be ordered separately)
SIMATIC HMI Manual Collection 6AV6691-1SA01-0AX0
Electronic documentation
on CD-ROM
5 languages (English, German,
French, Italian and Spanish);
contains: all currently available
user manuals, device manuals
and communication manuals for
SIMATIC HMI
ST80_2013_EN_Kap04.book Seite 165 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
HMI Software
Notes
4/166 Siemens ST 80 / ST PC · 2013
4
ST80_2013_EN_Kap04.book Seite 166 Freitag, 2. August 2013 2:42 14
© Siemens AG 2013
Siemens ST 80 / ST PC · 2013
5
PC-based Automation
5/2 SIMATIC Industrial PC
5/3 Rack PC
5/7 SIMATIC IPC547D
5/13 SIMATIC IPC647C
5/20 SIMATIC IPC847C
5/27 Box PC
5/30 SIMATIC IPC227D
5/36 SIMATIC IPC427D
5/39 SIMATIC IPC427C
5/44 SIMATIC IPC627C
5/47 SIMATIC IPC827C
5/50 SIMATIC Panel PC
5/53 SIMATIC IPC277D
5/58 SIMATIC IPC477D
5/63 SIMATIC HMI IPC477C
5/67 SIMATIC HMI IPC577C
5/71 SIMATIC HMI IPC677C
5/76 SIMATIC PC-based controllers
5/77 SIMATIC WinAC RTX
5/84 SIMATIC WinAC RTX F
5/90 SIMATIC WinAC ODK
5/91 Embedded Controller
5/93 EC31
5/100 Expansion modules
5/101 Embedded bundles/Software packages
5/102 SIMATIC IPC227D bundles
5/103 SIMATIC IPC427D bundles
5/104 SIMATIC IPC427C bundles
5/108 SIMATIC IPC277D bundles
5/109 SIMATIC IPC477D bundles
5/110 SIMATIC HMI IPC477C bundles
5/114 Software packages for SIMATIC IPC
and S7-mEC
5/117 Industrial monitors and thin clients
5/117 SIMATIC Industrial Flat Panel MT
5/120 SIMATIC Industrial Flat Panel
5/130 SIMATIC Flat Panels
5/134 SCD desk monitors SCD 19101
5/136 SCD monitors 1900
5/139 SIMATIC Industrial Thin Client
5/143 SIMATIC Thin Client
5/146 RMOS3 real-time operating system
5/147 RMOS3 V3.50 real-time operating system
5/149 RMOS3-GNU V3.0
5/150 RMOS3-TCP/IP V3.0
5/151 RMOS3-GRAPHX V1.0
5/152 BSP SIMATIC IPC V4.0 for RMOS3
5/153 Expansion components / accessories
5/155 SIMATIC IPC CompactFlash
5/155 SIMATIC IPC (Service) USB FlashDrive
5/156 PC I/O
5/161 SIMATIC Panel PC Remote Kit
5/163 SIMATIC IPC Image & Partition Creator
5/164 SIMATIC IPC DiagMonitor
5/165 SIMATIC IPC Remote Manager
5/166 SIMATIC IPC BIOS Manager
5/167 Input and output devices
5/167 SIMATIC PC keyboard
5/168 IP65 membrane keyboard, desk version
5/168 IP65 membrane keyboard,
19" built-in version
5/169 19" slide-in keyboard PS/2 with trackball
5/169 SIMATIC IPC mouse
5/170 SITOP power supplies
5/171 1-phase, 24 V DC/10 A (SITOP PSU100S)
5/171 1-phase, 24 V DC/20 A (SITOP PSU100S)
5/172 3-phase, 24 V DC/10 A (SITOP PSU300S)
5/172 3-phase, 24 V DC/20 A (SITOP PSU300S)
5/173 3-phase, 24 V DC/40 A (SITOP PSU300S)
5/174 24 V DC uninterruptible power supplies
5/176 DC UPS with capacitors
5/177 SITOP UPS500S
5/178 SITOP UPS500P
5/179 DC UPS with battery modules
5/181 DC UPS module 6 A,
DC UPS module 15 A
5/182 DC UPS module 40 A,
Battery module 1.2 Ah
5/183 Battery module 2.5 Ah,
Battery module 3.2 Ah
5/184 Battery module 7 Ah,
Battery module 12 Ah
5/185 MASTERGUARD power supply
5/186 Communication – Industrial Ethernet
5/186 Connection options to SIMATIC IPCs
5/187 CP 1604
5/188 CP 1616
5/189 CP 1612 A2
5/191 CP 1613 A2
5/192 CP 1623
5/193 CP 1628
5/194 HARDNET-IE S7-REDCONNECT
5/196 SOFTNET for Industrial Ethernet
5/198 SOFTNET-IE RNA
5/199 SOFTNET PN IO
5/201 OPC server for Industrial Ethernet
5/203 PN CBA OPC server
5/205 S7 OPC Redundancy
for Industrial Ethernet
5/206 SNMP OPC server
5/207 SINEMA server
5/208 Communication – PROFIBUS
5/208 Connection options to SIMATIC IPCs
5/209 CP 5603
5/211 CP 5613 A2
5/213 CP 5614 A2
5/215 CP 5623
5/217 CP 5624
5/219 CP 5512
5/221 CP 5612
5/223 CP 5622
5/225 CP 5711
5/227 SOFTNET for PROFIBUS
5/229 OPC server for PROFIBUS
5/230 S7 OPC Redundancy for PROFIBUS
ST80_2013_EN_Kap05.book Seite 1 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC Industrial PC
Industrial PC
5/2 Siemens ST 80 / ST PC · 2013
5
Overview
Industrial PC
Our reliable and innovative industrial PCs are the optimal
PC hardware platform for PC-based Automation from Siemens.
Rack PC
Rack PCs are flexible, high-availability industrial PC systems for
powerful yet compact applications using 19" technology.
Box PC
SIMATIC Box PCs provide mechanical engineers, plant
engineers and control cabinet makers with particularly rugged
industrial PC systems for use in powerful yet compact applica-
tions.
Panel PC
SIMATIC Panel PCs are suitable thanks to their high industrial
compatibility for use in control cabinets, consoles and control
panels, as well as directly on the machine. Typical areas of appli-
cation can be found in both factory and process automation.
Industrial monitors and thin clients
Flexible operator input concepts can be implemented via Flat
Panel monitors or thin clients. These are industry-standard LCD
monitors with high-contrast displays that can be located up to
30 m away from the PC, or low-cost, rugged thin clients that offer
HMI functionality over the network in larger plants spread over
wide areas.
Ruggedness and industrial compatibility
for 24-hour continuous use in an industrial environment
Compact, space-saving enclosure (Box PC and Panel PC)
Suitable for installing in space-saving control cabinets, only
500 mm deep (Rack PC)
All-metal enclosure with a high degree of electromagnetic
compatibility for use in industrial areas and in domestic,
business and commercial environments and for a degree of
protection up to IP65/NEMA 4
The mounting position of the devices can be varied by means
of wall, portrait or control cabinet mounting (Box PC), rail
mounting (SIMATIC IPC427D or IPC227D only) and horizontal
or vertical mounting position in the 19" cabinet or with the
appropriate kit as an industrial tower PC (Rack PC).
High resistance to shock/vibration thanks to special hard disk
mountings, locked connectors, and card retainers
Maintenance-free, due to design without hard disk and fans
using SIMATIC CompactFlash cards or solid-state drive
(SIMATIC IPC427D/IPC477D and SIMATIC IPC227D/
IPC277D)
Service-friendly, modular device design for replacement of
defective components
Integral industrial power supplies (according to NAMUR) for
safe power supplies protected against system disturbances
Attractive product design with dirt-repelling fronts and coated
surfaces
Dust protection thanks to a pressurized cooling concept, front-
mounted fans and dust filters (Rack PC)
More information
Notes on the scope of delivery
Microsoft operating systems are pre-installed in an OEM version.
The scope of supply also includes:
Recovery CD for simple reinstallation of the operating system
(not for Windows Embedded)
Restore DVD (hard disk image) for fast and very easy
restoration of the PC delivery status
SIMATIC IPC Documentation and Drivers DVD
Compact Operating Instructions
(German/English/French/Spanish/Italian/Chinese)
Electronic manual on IPC Documentation and Drivers DVD
(German/English)
Further information can be found in the Internet at:
http://www.siemens.com/simatic-ipc
Information material for ordering and for downloading is
available on the Internet:
http://www.siemens.com/simatic/printmaterial
ST80_2013_EN_Kap05.book Seite 2 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Rack PC
Rack PC
5/3
Siemens ST 80 / ST PC · 2013
Overview
Rack PCs are flexible, high-availability industrial PC systems for
powerful yet compact applications using 19" technology.
Three device classes are available for various requirements:
SIMATIC IPC547 – maximum performance at an attractive price
SIMATIC IPC647 – maximum compactness combined with
maximum industrial functionality
SIMATIC IPC847 – maximum expandability and industrial
functionality
Shared industrial functionality
Maximum system performance for complex automation tasks
and computationally intensive PC tasks in the industrial
environment through use of Intel Core processors
Designed for 24-hour continuous operation
Monitoring and diagnostics functions
(e.g. temperature, fan, watchdog)
RAID1 configuration (mirrored drives), optionally in "hot swap"
frames
Hard disks with capacities up to 1 TB for large volumes of data
Solid-state drive (SSD) with SLC technology, optional
Compact dimensions for installation in control cabinets only
500 mm deep
Dust protection thanks to overpressure ventilation concept
with fan on the front and dust filter
Lockable front panel or front door
Service-friendly equipment design due to prepared telescopic
rail mounting
Universal implementation as an industrial workstation or
server
Operating system preinstalled and activated for fast startup
Fast restoration of the delivery status of the HDD thanks to
restore DVD
High flexibility and expandability of components
PCI and PCI Express expansion slots
Independent industrial product design
ST80_2013_EN_Kap05.book Seite 3 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Rack PC
Rack PC
5/4 Siemens ST 80 / ST PC · 2013
Overview (continued)
5
SIMATIC IPC547D –
maximum performance at an attractive price
Intel Core i processors 2nd generation
Maximum processor performance in maximum configuration
without loss of power (throttling) at ambient temperatures of up
to 40 °C
Optional RAID5 configuration (striping with parity) in
"hot swap" frames
Redundant AC power supply, optional
Low noise output thanks to controlled fans
Status and alarm LEDs at the front for signaling critical system
states
Availability for at least 1.5 years
Guaranteed spare parts availability for at least 3 years
SIMATIC IPC647C – maximum compactness combined with
maximum industrial functionality
Maximum compactness due to 3 free PCI/PCI Express slots
for installing long expansion cards and integrated interfaces
for communication, e.g. integrated PROFIBUS/MPI or
PROFINET interface
High thermal stability up to 50°C even at maximum processor
performance
High vibration/shock resistance thanks to special hard disk
holders
Intel Core i processors
Enhanced server functionality:
Hardware RAID PCIe x8 controller with zero-maintenance
cache protection module, SAS hard disks in hot-swap frame
with capacities up to 1 TB for large volumes of data
Redundant AC power supply, optional
ECC memory, optional
Service-friendly device design due, for example, to the
replacement of filters/fans from the front without the need for
tools, or opening of the enclosure with just one screw.
Front LED concept for efficient self-diagnostics, e.g.
monitoring of the hard disks in RAID1 configurators, fans or
the status display for Ethernet, PROFINET and PROFIBUS.
Integrated PROFIBUS DP/MPI or PROFINET interface
(optional)
High continuity of the components/design
Motherboard developed and manufactured by Siemens
Availability for up to 6 years
Guaranteed spare parts availability for at least 5 years
SIMATIC IPC847C – maximum expandability and industrial
functionality
Maximum expandability due to 11 free PCI/PCI Express slots
for installing long expansion cards and integrated interfaces
for communication, e.g. integrated PROFIBUS/MPI or
PROFINET interface
High thermal stability up to 50°C even at maximum processor
performance
High vibration/shock resistance thanks to special hard disk
holders
Intel Core i processors
Optional RAID5 configuration (striping with parity)
in "hot swap" frames
Extended server functionality:
Hardware RAID PCIe x8 controller, SAS hard disks in hot-swap
frame with capacities up to 1 TB for large volumes of data
Redundant AC power supply, optional
SATA hard disks with capacities up to 500 GB for large
volumes of data
ECC memory, optional
Service-friendly device design due, for example, to the
replacement of filters/fans from the front without the need for
tools, or opening of the enclosure with just one screw.
Front LED concept for efficient self-diagnostics, e.g.
monitoring of the hard disks in RAID1 configurators, fans or
the status display for Ethernet, PROFINET and PROFIBUS.
Integrated PROFIBUS DP/MPI or PROFINET interface
(optional)
High continuity of the components/design
Motherboard developed and manufactured by Siemens
Availability for up to 6 years
Guaranteed spare parts availability for at least 5 years
ST80_2013_EN_Kap05.book Seite 4 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Rack PC
Rack PC
5/5
Siemens ST 80 / ST PC · 2013
Overview (continued)
SIMATIC IPC547D SIMATIC IPC647C SIMATIC IPC847C
Design
19" rack 4 HU 2 HU 4 HU
Prepared for telescopic rails
Horizontal/vertical installation • / • • / - • / •
19" mounting bracket can be removed
from outside
Tower Kit (optional) -
General features
Processor Intel Core i7-2600
(4C/8T, 3.40 GHz)
Intel Core i5-2400
4C/4T, 3.10 GHz)
Intel Pentium G850
(2C/2T, 2.90 GHz)
• Intel Core i7-610E
(2C/4T, 2.53 GHz)
Intel Core i5-520E
(2C/4T, 2.4 GHz)
• Intel Core i3-330E
(2C/4T, 2.13 GHz)
• Intel Core i7-610E
(2C/4T, 2.53 GHz)
Intel Core i5-520E
(2C/4T, 2.4 GHz)
• Intel Core i3-330E
(2C/4T, 2.13 GHz)
Main memory 1 GB, expandable up to 32 GB 1 GB, expandable up to 8 GB
• ECC optional 1 GB, expandable up to 8 GB
• ECC optional
Slots for expansions
(all long, up to 312 mm) •4x PCI
• 1 x PCI Express x16
1 x PCI Express x16 (4 lanes)
• 1 x PCI Express x8
(1 lane)
•2x PCI
• 1 x PCI Express x16
or
•1x PCI
• 1 x PCI Express x8 (4-lane)
• 1 x PCI Express x16
•7x PCI
• 1 x PCI Express x16
• 3 x PCI Express x4
or
•7x PCI
• 1 x PCI Express x16
Onboard graphics 1 x DisplayPort
•1x DVI-I
•1x VGA
(via adapter cable, optional)
•1x DVI-I
•1x VGA
(via adapter cable, optional)
•1x DVI-I
• 1 x VGA
(via adapter cable, optional)
Graphics card (optional) • PCI Express x16
(2 x VGA or 2 x DVI-D) PCI Express x16
(2 x VGA or 2 x DVI-D) PCI Expressx16
(2 x VGA or 2 x DVI-D)
Operating system
without • • •
Preinstalled and activated,
supplied on restore DVD Windows XP Professional
Multi-Language (32-bit)
Windows 7 Ultimate Multi-Language
(32/64-bit)
Windows Server 2008 incl. 5 Client
Multi-Language (32-bit)
Windows Server 2008 R2 incl.
5 Clients Multi-Language (64-bit)
• Windows XP Professional
Multi-Language (32-bit)
Windows 7 Ultimate Multi-Language
(32/64-bit)
• Windows Server 2003 R2 incl.
5 Clients Multi-Language (32-bit)
Windows Server 2008 incl. 5 Clients
Multi-Language (32-bit)
• Windows Server 2008 R2 incl.
5 Clients Multi-Language (64-bit)
Windows XP Professional
Multi-Language (32-bit)
Windows 7 Ultimate Multi-Language
(32/64-bit)
Windows Server 2003 R2 incl.
5 Clients Multi-Language (32-bit)
Windows Server 2008 incl. 5 Clients
Multi-Language (32-bit)
Windows Server 2008 R2 incl.
5 Clients Multi-Language (64-bit)
Order separately -RMOS3 V3.50 RMOS3 V3.50
Project-specific on request • Linux
1)
•Other Linux
1)
• Other •Linux
1)
• Other
Interfaces
PROFIBUS/MPI -12 Mbit/s (CP 5611-compatible),
optional 12 Mbit/s (CP 5611-compatible),
optional
PROFINET -3 x RJ45 (CP 1616-compatible),
optional 3 x RJ45 (CP 1616-compatible),
optional
Ethernet 2 x 10/100/1000 Mbit/s 2 x 10/100/1000 Mbit/s 2 x 10/100/1000 Mbit/s
USB 2.0 (high current) 11 x, 2 of which at front, 1 x internal 7 x , 2 of which at front, 1 x internal 7 x , 2 of which at front, 1 x internal
VGA • optional • optional • optional
DVI
DisplayPort - -
ST80_2013_EN_Kap05.book Seite 5 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Rack PC
Rack PC
5/6 Siemens ST 80 / ST PC · 2013
Overview (continued)
5
• Available
- Not available
1)
Suitable for specific Linux versions in accordance with the specifications
of the Siemens manufacturer's declaration "Suitable for Linux", see
http://www.siemens.com/simatic-pc/suited-for-linux
(Linux is a trademark of Linus Torvald)
2)
Restrictions when using DVD±R/RW and hard disks in swap frame.
More information
Further information can be found in the Internet under:
http://www.siemens.com/simatic-pc
Information material can be ordered or downloaded from the
Internet:
http://www.siemens.com/simatic/printmaterial
Drives
SATA hard disks
Internal installation -
Installation at the front in the swap
frame
• Internal installation in drive holder
(shock and vibration-damped) -
RAID1/5 configuration
with onboard RAID • / • • / - • /•
Solid-state drive (SSD), SLC
Hard disks SAS
Installation at the front in the swap
frame -
RAID1/5 configuration with HW RAID
controller PCI x 8 incl. zero mainte-
nance cache protection module
- / - • / - • /•
Optical drives
DVD-ROM -
DVD±R/RW
AC power supply
Redundant (optional)
Ambient conditions
2)
Vibration/shock load
during operation 0.2g / 1g 0.5 g / 5 g 0.5g / 5g
Ambient temperature
during operation With maximum configuration:
5...40 °C With maximum configuration:
5...5C With maximum configuration:
5 ... 50 °C
SIMATIC IPC547D SIMATIC IPC647C SIMATIC IPC847C
ST80_2013_EN_Kap05.book Seite 6 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC547D
5/7
Siemens ST 80 / ST PC · 2013
Overview
The SIMATIC IPC547D is a rugged industrial PC in 19" rack
design (4 HU).
It offers:
Maximum performance
Attractive price
Intel Core i technology
Technical specifications
SIMATIC IPC547D
General features
Design 19" rack, 4 HU, externally painted
Processor • Intel Core i7-2600
(4C/8T, 3.40 GHz, 8 MB Last Level
Cache, Turbo Boost 2.0, EM64T,
VT-x/-d, iAMT)
Intel Core i5-2400
(4C/4T, 3.10 GHz, 6 MB Last Level
Cache, Turbo Boost 2.0, EM64T,
VT-x/-d, iAMT)
Intel Pentium Dual Core G850
(2C/2T, 2.90 GHz, 3 MB Last Level
Cache, EM64T, VT)
Chipset Intel Q67
Main memory From 1 GB DDR3 1333 SDRAM
• Dual channel support
4 DIMM base
Expandable up to 32 GB
1)
Spare slots for expansions (all long) •4x PCI
• 1 x PCI Express x16
1 x PCI-Express x16 (4 lanes)
1 x PCI-Express x8 (1 Lane)
Graphics • Onboard Intel HD 2000 graphics
controller integrated into the pro-
cessor; Shared Video Memory up
to 1.7 GB; up to 2560 x 1600 pix-
els at 60 Hz image refresh rate
and 32-bit colors
PCI Express graphics card (Dual
Head: 2 x VGA or 2 x DVI-D) in the
PCIe x16 slot; 512 MB; up to
2048 x 1536 pixels at 85 Hz im-
age refresh rate and 32 bit colors
(optional)
Operating system • without
Preinstalled and activated
(supplied on restore DVD):
Windows XP Professional MUI
(32-bit)
• Windows 7 Ultimate MUI
(32/64-bit)
Windows Server 2008 incl.
5 Client MUI (32 bit)
Windows Server 2008 R2 incl.
5 Client MUI (64 bit)
MUI (Multilanguage User Interface,
5 languages): English, German,
French, Italian, Spanish
Project-specific on request:
•Linux
2)
•Other
Power supply 100 ... 240 V AC, 50 ... 60 Hz, with
bridging of short-term power fail-
ures: max. 20 ms at 0.85% rated
voltage
Redundant 100 ... 240 V AC,
50 ... 60 Hz
1)
Memory information:
In order to use a memory with more than 4 GB, a 64-bit operating system is
required. In the case of configurations with 4 GB, the visible memory can
be reduced to about 3.5 GB or less (with 32-bit operating systems).
In configurations with 8 GB, the visible memory can be reduced to about
7.5 GB or less.
2)
Suitable for specific LINUX versions in accordance with the specifications
of the Siemens manufacturer's declaration "Suitable for LINUX", see
http://www.siemens.com/simatic-pc/suited-for-linux
(LINUX is a trademark of Linus Torvald).
ST80_2013_EN_Kap05.book Seite 7 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC547D
5/8 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
5
Drives
Hard disk, SATA 3.5"
with NCQ technology
Solid State Drive, SATA 2.5"
with SLC technology
Installation in internal drive support
•500GB
•1TB
•RAID1
3)
1 TB
(2 x 1 TB, mirror disks)
50 GB solid-state drive
Installation at the front in swap
frame (low profile)
•500GB
•2x 500GB
•RAID1
3)
1 TB (2 x 1 TB, mirror
disks), "hot swap"
•RAID5
3)
2 TB (3 x 1 TB, striping
with parity), "hot swap"
50 GB solid-state drive
•RAID1
3)
1 TB (2 x 1 TB, mirror
disks), "hot swap" + 50 GB solid-
state drive (operating system in-
stalled on SSD if configured)
DVD-ROM, 5.25", SATA 16 x (DVD media)
32 x (CD media)
DVD±R/RW, 5.25", SATA 16x 24x 8x(DVD media)
48 x 48 x 32 x (CD media)
Slots for drives Front:
3 x 5.25"
1 x 3.5"
Internal:
2 x 3.5"
Interfaces
Ethernet 2 x Intel Gbit Ethernet
(RJ45, teaming-capable)
USB 2.0 • 2 x front (high current)
8 x rear (high current)
1 x internal (high current),
e.g. for USB dongle with
optional interlocking
Serial 9-pole COM1 (V.24);
COM2 (V.24) (optional)
Parallel LPT (optional)
VGA Optionally via adapter cable
DVI-I 1x
DisplayPort 1x
Keyboard PS/2
Mouse PS/2
Audio 1 x Line In; 1 x Line Out; 1 x Micro
3)
SATA RAID controller onboard in Intel Q67 chipset
4)
Restrictions in use of optical drives and HDD in swap frames.
SIMATIC IPC547D
Monitoring functions
Basic functionality Message locally
via DiagBase software
Temperature When permitted operating temper-
ature range is exceeded
Fan Speed monitoring
1 x front fan
1 x CPU fan
• 1 x power supply fan
Watchdog Monitoring of program execution
Monitoring time can be parame-
terized in software
Monitoring functions via the network SIMATIC IPC DiagMonitor Version
V4.3.x.x or higher (optional)
Remote monitoring capability for:
• Watchdog
•Temperature
•Fan speed
•Battery
Hard disks (SMART)
• System/Ethernet
Communication:
Ethernet interface
(SNMP protocol)
OPC for integration
in SIMATIC software
Client server architecture
Structure of log files
Front LEDs POWER (PC switched on)
• HDD (access to hard disk)
TEMP (temperature monitoring)
FAN (fan monitoring)
Additional HDD alarm LEDs for
RAID configurations behind the
front flap
Ambient conditions
Degree of protection IP30 front, IP20 rear according to
EN 60529
Dust protection With the front door closed accord-
ing to IEC 60529 filter class G2
EN 779, 99% of particles > 0.5 mm
are filtered
Protection class Protection class I according to
IEC 61140
Vibration load during operation
4)
IEC 60068-2-6, 10 cycles
20 ... 58 Hz: 0.015 mm
58 ... 200 Hz: 2 m/s
2
(approx. 0.2 g)
Shock load in operation
4)
IEC 60068-2-27
Half-sine: 9.8 m/s
2
, 20 ms
(approx. 1 g),
100 shocks per axis
SIMATIC IPC547D
ST80_2013_EN_Kap05.book Seite 8 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC547D
5/9
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
Note regarding SIMATIC PC operating system licenses
The accompanying operating system license is only valid for
installation on the respective supplied SIMATIC IPC. Installation
can only be performed on these SIMATIC systems in accor-
dance with Microsoft OEM licensing regulations.
Electromagnetic compatibility (EMC)
Emitted interference EN 61000-6-3; EN 61000-6-4;
CISPR 22 / EN 55022 Class B;
FCC Class A;
EN 61000-3-2 Class D;
EN 61000-3-3
Immunity to conducted interference on
the supply lines • ± 2 kV (IEC 61000-4-4, burst)
•± 1kV
(IEC 61000-4-5, symm. surge)
•± 2 kV
(IEC 61000-4-5, asymm. surge)
Immunity to interference on signal lines • ±2 kV (IEC 61000-4-4, burst,
length > 30 m)
± 1 kV (IEC 61000-4-4, burst,
length < 30 m)
± 2 kV (IEC 61000-4-5, surge,
length > 30 m)
Immunity to static discharge ± 4 kV, contact discharge
(IEC 61000-4-2)
• ±8 kV, air discharge
(IEC 61000-4-2)
Immunity to high radio frequency inter-
ference 1 V/m 80% AM; 2 ... 2.7 GHz
(IEC 61000-4-3)
10 V/m 80% AM;
80 MHz ... 1 GHz and
1.4GHz 2GHz
(IEC 61000-4-3);
10 V, 10 kHz ... 80 MHz
(IEC 61000-4-6)
Immunity to magnetic fields 100 A/m, 50/60 Hz (IEC 61000-4-8)
Ambient temperature during operation 5...40 °C
Note:
Limitations for operation
of DVD±R/RW
Humidity during operation 5 ... 80% at 25 °C
(no condensation)
SIMATIC IPC547D
Approvals and safety regulations
Safety regulations IEC 60950-1; UL60950; CSA
Approvals cULus 60950
CE mark For use in industrial areas as well
as domestic, business and com-
mercial environments:
Emitted interference:
EN 61000-6-3:2007
Noise immunity:
EN 61000-6-2:2005
Dimensions and weights
Mounting dimensions (W x H x D)
in mm 434 x 177 x 446
Weight, approx. 19 kg
SIMATIC IPC547D
ST80_2013_EN_Kap05.book Seite 9 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC547D
5/10 Siemens ST 80 / ST PC · 2013
5
Ordering data
Order No. Order No.
SIMATIC IPC547D
1)
6AG4104- 2
7777-7 7 7 7
Interfaces:
2 x Gbit Ethernet (RJ45),
1 x DisplayPort, 1 x DVI-I,
8 x USB on the rear,
2 x USB on the front,
1 x USB internal,
1 x serial (COM1), 2 x PS/2,
audio; 7 slots (all long):
4 x PCI, 1 x PCIe x16,
1 x PCIe x16 (4 lanes),
1 x PCIe x8 (1 lane);
mounting locations:
6 (3 x 5.25", 1 x 3.5" externally
accessible; 2 x 3.5" internal);
temperature and fan monitoring;
watchdog; card retainer
Processors
Pentium Dual Core G850
(2C/2T, 2.90 GHz, 3 MB Last Level
Cache, EM64T, VT)
A
• Core i5-2400 (4C/4T, 3.10 GHz,
6 MB Last Level Cache, Turbo
Boost 2.0, EM64T, VT-x/-d, iAMT)
C
• Core i7-2600 (4C/8T, 3.40 GHz,
8 MB Last Level Cache, Turbo
Boost 2.0, EM64T, VT-x/-d, iAMT)
D
Drives
500 GB HDD SATA; internal A
1 TB HDD SATA; internal B
RAID1, 1 TB (2 x 1 TB HDD SATA,
mirror disks); internal
2)
D
50 GB solid-state drive (SLC)
SATA; internal E
500 GB HDD SATA in swap frame;
front G
2 x 500 GB HDD SATA in swap
frame; front H
RAID1, 1 TB (2 x 1 TB HDD SATA,
mirror disks) in swap frame; for hot
swapping; at the front
P
RAID5, 2 TB (3 x 1 TB HDD SATA,
striping with parity) in swap frame;
for hot swapping; at the front
R
50 GB solid-state drive (SLC) SATA
in swap frame; at the front S
RAID1, 1 TB (2 x 1 TB HDD SATA,
mirror disks) in swap frame; hot
swapping; at the front + 50 GB sol-
id-state drive (SLC) SATA in swap
frame; at the front (operating sys-
tem installed on SSD, if config-
ured)
T
Memory configuration
1 GB DDR3 SDRAM
(1 x 1 GB), single channel 0
2 GB DDR3 SDRAM
(2 x 1 GB), dual channel 1
4 GB DDR3 SDRAM
(2 x 2 GB), dual channel 2
8 GB DDR3 SDRAM
3)
(2 x 4 GB), dual channel 3
• 16 GB DDR3 SDRAM
3)
(4 x 4 GB), dual channel 4
• 32 GB DDR3 SDRAM
3)
(4 x 8 GB), dual channel 5
1)
For an up-to-date overview, see the SIMATIC PC online configurator at:
www.siemens.com/ipc-configurator
2)
Not in combination with redundant power supply
3)
Can only be used on 64-bit operating systems
SIMATIC IPC547D
1)
(continued) 6AG4104- 2
7 7 7 7 -7777
Removable media
•DVD-ROM 1
•DVD±RW 2
Expansions (hardware)
• Without expansions (HW);
onboard graphics 0
• No expansions (HW); onboard
graphics; DVI-I VGA-compliant
adapter cable for onboard
graphics
1
• Serial (COM2) & parallel (LPT);
onboard graphics 2
• Serial (COM2) and parallel (LPT);
onboard graphics; DVI-I VGA-
compliant adapter cable for on-
board graphics
3
• Serial (COM2) & parallel (LPT)
+ PCIe x16 graphics card (Dual
Head: 2 x VGA or 2 x DVI-D),
512 MB
4
Operating systems
(preinstalled and activated)
• Windows XP Professional, MUI
(Eng, Ger, Fr, It, Sp), 32-bit, SP3 B
• Windows 7 Ultimate, MUI
(Eng, Ger, Fr, It, Sp), 32 bit,
SP1 enclosed
E
• Windows 7 Ultimate, MUI
(Eng, Ger, Fr, It, Sp), 64 bit,
SP1 enclosed
F
• Windows Server 2008 Standard
Edition incl. 5 Client, MUI
(Eng, Ger, Fr, It, Sp), 32 bit, SP2
P
Windows Server 2008 R2 Standard
Edition incl. 5 clients, MUI
(Eng, Ger, Fr, It, Sp), 64 bit,
SP1 enclosed
Q
• Without operating system X
Expansions (software)
• SIMATIC IPC DiagMonitor V4.3
software included A
• SIMATIC IPC Image & Partition
Creator V3.2 software included B
• SIMATIC IPC DiagMonitor V4.3 +
Image & Partition Creator V3.2
software included
C
• Without expansions (software) X
Power supply, with country-specific
cable:
• 100/240 V AC industrial power
supply; power cable for Europe 0
• 100/240 V AC industrial power
supply; USA power cable 4
• 100/240 V AC industrial power
supply; power cable for China 5
2 x 100/240 V AC redundant indus-
trial power supply; without power
cable
6
ST80_2013_EN_Kap05.book Seite 10 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC547D
5/11
Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
Note:
Software Packages with SIMATIC WinCC flexible,
SIMATIC WinCC RT Advanced, SIMATIC WinCC, and
SIMATIC WinAC RTX (F) can be ordered together with the
SIMATIC IPC at favorable prices.
More information under
"Embedded Bundles / Packages for industrial PCs".
Preferred variants (ex-stock)
SIMATIC IPC547D
Pentium Dual Core G850
(2C/2T, 2.90 GHz, 3 MB Last Level
Cache, EM64T, VT); 500 GB HDD
SATA internal; 1 GB DDR3 SDRAM
(1 x 1 GB), single channel;
DVD-ROM; interfaces:
2 x Gbit Ethernet (RJ45),
1 x serial, 8 x USB rear,
2 x USB front, 1 x USB internal,
2 x PS/2, audio;
100/240 V industrial power supply,
power cable for Europe;
without operating system
6AG4104-2AA01-0XX0
• Core i5-2400 (4C/4T, 3.10 GHz,
6 MB Last Level Cache, Turbo
Boost 2.0, EM64T, VT-x/-d, iAMT);
RAID1, 1 TB (2 x 1 TB HDD SATA,
mirror disks) in swap frame,
for hot swapping, at the front;
4 GB DDR3 SDRAM (2 x 2 GB)
dual channel; DVD±RW;
interfaces: 2 x Gbit Ethernet
(RJ45), 2 x serial, 1 x parallel,
8 x USB rear, 2 x USB front,
1 x USB internal, 2 x PS/2, Audio;
100/240V industrial power supply,
power cable for Europe;
without operating system
6AG4104-2CP22-2XX0
• Core i7-2600 (4C/8T, 3.40 GHz,
8 MB Last Level Cache, Turbo
Boost 2.0, EM64T, VT-x/-d, iAMT);
RAID1, 1 TB (2 x 1 TB HDD SATA,
mirror disks) in swap frame,
for hot swapping, at the front;
8 GB DDR3 SDRAM (2 x 4 GB)
dual channel; DVD±RW;
interfaces: 2 x Gbit Ethernet
(RJ45), 2 x serial, 1 x parallel,
8 x USB rear, 2 x USB front,
1 x USB internal, 2 x PS/2, audio;
100/240 V industrial power supply,
power cable for Europe, Windows
7 Ultimate MUI (Eng, Ger, Fr, It,
Sp), 64-bit, SP1 supplied
6AG4104-2DP32-2FX0
Accessories
Memory expansion
• 1 GB DDR3 1333 SDRAM, DIMM
(1 x 1 GB) 6ES7648-2AJ40-0LA0
• 2 GB DDR3 1333 SDRAM, DIMM,
kit for dual-channel technology
(2 x 1 GB)
6ES7648-2AJ50-0LB0
• 4 GB DDR3 1333 SDRAM, DIMM,
kit for dual-channel technology
(2 x 2 GB)
6ES7648-2AJ60-0LB0
• 8 GB DDR3 1333 SDRAM, DIMM,
kit for dual-channel technology
(2 x 4 GB)
6ES7648-2AJ70-0LB0
Tower Kit 6ES7648-1AA00-0XC0
For converting the computer into an
industrial tower PC
Retainer 6ES7648-1AA00-0XK0
for pin assignment of the internal
USB port
Power cable, straight, 3 m long
• Austria, Belgium, Finland, France,
Germany, Netherlands, Spain,
Sweden
6ES7900-0AA00-0XA0
• United Kingdom 6ES7900-0BA00-0XA0
• Switzerland 6ES7900-0CA00-0XA0
•USA 6ES7900-0DA00-0XA0
•Italy 6ES7900-0EA00-0XA0
• China 6ES7900-0FA00-0XA0
Rack unit for low-profile
HDD swap frame 6ES7648-0EG00-1BA0
for 3.5" hard disk, SATA
(without hard disk)
Expansion components From page 5/153
ST80_2013_EN_Kap05.book Seite 11 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC547D
5/12 Siemens ST 80 / ST PC · 2013
5
Dimensional drawings
All dimensions in mm. For mounting cut-out see technical
specifications.
The fixing screws of the telescopic rails should not project more
than 5 mm into the enclosure.
The enclosure is prepared for the following telescopic rails:
Rittal: Type 3659.180 for 600 mm cabinet /
Type RP 3659.190 for 800 mm cabinet
Schroff: Type 20110-072
More information
Further information can be found on the Internet at:
http://www.siemens.com/simatic-pc
Technical data of the telescopic rails
Carrying capacity per pair, min. 30 kg
Full extension length, min. 470 mm
Rail thickness, max. 9.7 mm
Fixing screws M5 x 6 mm
G_ST80_XX_00452
489
481.4
101.6
445.5
14.3
18.5 37.5
176.5
465.1
433.5
ST80_2013_EN_Kap05.book Seite 12 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC647C
5/13
Siemens ST 80 / ST PC · 2013
Overview
The SIMATIC IPC647C is a very rugged, high-performance
industrial PC in 19" rack design (2 HMs) with excellent industrial
functionality.
It offers:
Extreme compactness
Extreme ruggedness
Intel Core i technology
Technical specifications
SIMATIC IPC647C
General features
Design 19" rack, 2 HUs, external coating
Processor • Intel Core i7-610E
(2C/4T, 2.53 GHz, 4 MB cache,
Turbo Boost, VT-d, iAMT, EM64T)
Intel Core i5-520E
(2C/4T, 2.4 GHz, 3 MB cache,
Turbo Boost, VT-d, iAMT, EM64T)
Intel Core i3-330E
(2C/4T, 2.13 GHz, 3 MB cache,
EM64T)
Chipset Intel QM57
Main memory from 1 GB DDR3 1066 SDRAM
• Dual channel support
2 DIMM slots
Expandable up to 8 GB,
optional ECC
1)
Spare slots for expansions (all long) 2 x PCI
• 1 x PCI Express x16
or
1 x PCI
• 1 x PCI Express x8 (4 lane)
• 1 x PCI Express x16
Graphics • Onboard Intel GMA HD graphics
controller integrated into proces-
sor; dynamic video memory; up to
2048 x 1536 pixels with 75 Hz
refresh rate and 16-bit colors
PCI Express graphics card
(Dual Head: 2 x VGA or 2 x DVI-D
via display port adapter) in the
PCIe x16 slot; 256 MB; up to
2048 x 1536 pixels with 75 Hz
refresh rate and 32-bit colors
(optional)
1)
Memory information:
In order to use a memory with more than 4 GB, a 64-bit operating system is
required. In the case of configurations with 4 GB, the visible memory can
be reduced to about 3.5 GB or less (with 32-bit operating systems).
In configurations with 8 GB, the visible memory can be reduced to about
7.5 GB or less.
ST80_2013_EN_Kap05.book Seite 13 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC647C
5/14 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
5
Operating system without
• Preinstalled, activated,
and supplied on restore DVD
Windows XP Professional MUI,
32-bit
• Windows 7 Ultimate MUI,
32/64-bit
Windows Server 2003 R2
incl. 5 client MUI, 32-bit
Windows Server 2008
incl. 5 client MUI, 32-bit
Windows Server 2008 R2 incl.
5 client MUI, 64-bit
MUI: Multi-language User Interface;
5 languages (English, French,
German, Italian, Spanish)
Project-specific on request
2)
•Other
Power supply 100 ... 240 V AC, 50 ... 60 Hz;
with bridging of temporary power
failures in accordance with
NAMUR: max. 20 ms at
0.85% rated voltage
Redundant 100 ... 240 V AC,
50 ... 60 Hz
Drives
Hard disks: SATA 3.5" or SAS 3.5" Mounted in internal shock/
vibration-resistant drive cage
•250 GB
•500 GB
•2x 500GB
•500 GB RAID1
3)
,
(2 x 500 GB, mirror disks)
Mounted in front drive cage
in swap frame (low profile)
•250 GB
•500GB
•2x 500GB
•500 GB RAID1
3)
,
(2 x 500 GB, mirror disks),
"hot swap"
1 TB RAID1,
(2 x 1 TB HDD SAS, mirror disks),
"hot swap"; RAID controller in
PCIe x8 slot with zero-mainte-
nance cache protection module
Solid-State Drive (SSD) (2.5" SATA) Installed internally or front-mounted
in removable frame
• 50 GB (SLC), optional
DVD+/-R/RW, slimline 8x 8x 6x(DVD media)
24 x 24 x 24 x (CD media)
Slots for drives Front:
• 2 x low profile swap frames
(for 3.5" HDD)
• 1 x 12.7 mm slimline
(for ODD or CF drive)
Internal:
2 x 3.5" as an alternative to swap
frames (in the optional, shock and
vibration-damped drive cage)
SIMATIC IPC647C
Interfaces
PROFINET 3 x RJ45 (CP 1616-compatible),
optional
PROFIBUS/MPI 12 Mbit/s (isolated, compatible with
CP 5611), optional
Ethernet 2 x 10/100/1000 Mbit/s
(RJ45, teaming-capable)
USB 2.0 • 2 x front (high current)
4 x rear (high current)
• 1 x internal (high current), e.g.
for USB dongle with optional lock
Serial • 9-pin COM1 (V.24)
• 9-pin COM2 (V.24)
Parallel LPT1
VGA 1 x
Keyboard PS/2
Mouse PS/2
Audio 1 x Line Out; 1 x Micro
2)
Suitable for specific LINUX versions in accordance with the specifications
of the Siemens manufacturer's declaration "Suitable for LINUX", see
(LINUX is a trademark of Linus Torvald).
3)
SATA RAID controller on board in Intel chipset
SIMATIC IPC647C
ST80_2013_EN_Kap05.book Seite 14 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC647C
5/15
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
Monitoring functions
Basic functionality Message locally via DiagBas
e software
Temperature • Overshoot/undershoot of permis-
sible operating temperature range
Messages can be evaluated by
the application program
Fan Speed monitoring
• 2 x enclosure fan (front)
•1 x power supply fan
Watchdog • Monitoring of program execution
Monitoring time can be parame-
terized in software
Restart can be parameterized in
the event of a fault
Messages can be evaluated by
the application program
Monitoring functions via the network SIMATIC IPC DiagMonitor (optional)
Version 4.3 and higher
Remote monitoring capability for:
• Watchdog
•Temperature
•Fan speed
• Hard disk monitoring (SMART)
Redundant power supply
(module)
System/Ethernet monitoring
(Heartbeat)
Communication:
Ethernet interface
(SNMP protocol)
OPC for integration in
SIMATIC software
Configuration of
client/server architectures
Structure of log files
Front LEDs POWER (internal power supply
unit, PC switched on)
HARDDISK (access to hard disk)
• ETHERNET1
(Ethernet status, "Heartbeat")
• ETHERNET2
(Ethernet status, "Heartbeat")
• PROFIBUS/MPI
(PROFIBUS status)
SF PROFINET (PROFINET status)
• WATCHDOG
(ready/fault indication)
TEMP (temperature status)
FAN (fan speed monitoring)
HDD1 ALARM (hard disk alarm
in conjunction with RAID1 and
monitoring software)
HDD2 ALARM (hard disk alarm
in conjunction with RAID1 and
monitoring software)
SIMATIC IPC647C
Ambient conditions
Degree of protection IP41 at the front, IP20 at the rear
acc. to EN 60529
Dust protection with front door closed: G2 EN 779,
99% of particles > 0.5 mm are held
back
Protection class Protection class I in accordance
with IEC 61140
Vibration load during operation DIN EN 60068-2-6, 10 cycles
Internal mounting of the hard disk
drives in optional, internal drive
cage:
10 ... 58 Hz: 0.0375 mm;
58 ... 500 Hz: 5 m/s2
(approx. 0.5 g)
Note:
There are limitations when
DVD+/-RW and HDD are operated
in a swap frame
Shock loading during operation DIN EN 60068-2-27,
IEC 60068-2-29
Internal mounting of the hard disk
drives in optional, internal drive
cage:
Half-sine: 50 m/s
2
, 30 ms
(ca. 5 g), 100 shocks per axis
Note:
There are limitations when
DVD+/-RW and HDD are operated
in a swap frame
Electromagnetic compatibility (EMC)
Emitted interference (AC) EN 61000-6-3, EN 61000-3-3,
EN 61000-3-2 Class D;
FCC Class A
Immunity to conducted interference on
the supply lines ± 2 kV (IEC 61000-4-4, burst)
± 1 kV
(IEC 61000-4-5, symm. surge)
± 2 kV
(IEC 61000-4-5, asymm. surge)
Immunity to interference on signal lines ± 1 kV (IEC 61000-4-4, burst,
length < 30 m)
± 2 kV (IEC 61000-4-4, symm.
surge, length > 30 m)
± 2 kV (IEC 61000-4-5, asymm.
surge, length > 30 m)
SIMATIC IPC647C
ST80_2013_EN_Kap05.book Seite 15 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC647C
5/16 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
5
Note regarding SIMATIC PC operating system licenses
The accompanying operating system license is only valid for
installation on the respective supplied SIMATIC IPC. Installation
can only be performed on these SIMATIC systems in accor-
dance with Microsoft OEM licensing regulations.
Immunity to static discharge ±6 kV, contact discharge
(IEC 61000-4-2)
±8 kV, air discharge
(IEC 61000-4-2)
Immunity to high radio frequency
interference •1V/m 80% AM 1kHz;
2 ... 2.7 GHz (IEC 61000-4-3)
10 V/m 80% AM 1 kHz;
80 MHz - 1 GHz and
1.4 GHz - 2 GHz (IEC 61000-4-3);
10 V, 10 kHz to 80 MHz
(IEC 61000-4-6)
Immunity to magnetic fields 100 A/m, 50/60 Hz (IEC 61000-4-8)
Ambient temperature during operation 5 … 50 °C
Note:
There are limitations when
DVD+/-RW and HDD are operated
in a swap frame
Relative operating humidity 5 ... 85 % at 30 °C
(no condensation)
Approvals and safety regulations
Safety regulations IEC 60950-1 Second Edition,
EN 60950-1, UL 60950,
CSA C22.2 No 60950
Approvals cULus 60950, KCC
Marine approval
(only for configurations with
CompactFlash or SSD memory)
• GL –- Germanische Lloyd
BV – Bureau Veritas
• LR – Lloyds Register of Shipping
ABS – American Bureau of
Shipping
DNV – Det Norske Veritas
NKK – Nippon Kaiji Kyokai
CE mark Use in industry:
• Noise immunity:
EN 61000-6-2:2005
Use in domestic environments:
• Emitted interference:
EN 61000-6-3:2007
Dimensions and weights
Mounting dimensions
(W x H x D, in mm) 430 x 88 x 445
SIMATIC IPC647C
ST80_2013_EN_Kap05.book Seite 16 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC647C
5/17
Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
SIMATIC IPC647C
1)
6AG4112- 1
777 7 -7 7 7 7
Interfaces:
2 x 10/100/1000 Mbps Ethernet
(RJ45); 1 x graphic (DVI-I);
2x COM; 1 x LPT; 2x PS/2;
4 x USB 2.0 at rear, 2 x USB 2.0
at front; 1 x USB 2.0 internal; audio;
temperature and fan monitoring,
watchdog; card retainer
Processor/motherboard
• Core i3-330E
(2C/4T, 2.13 GHz, 3 MB cache),
motherboard without fieldbus
G
• Core i3-330E
(2C/4T, 2.13 GHz, 3 MB cache),
motherboard with PROFIBUS/MPI
H
• Core i3-330E
(2C/4T; 2.13 GHz, 3 MB cache),
motherboard with PROFINET
(3 x RJ45, CP 1616-compatible)
2)
J
• Core i5-520E
(2C/4T, 2.4 GHz, 3 MB cache,
TB, iAMT, VT), motherboard
without fieldbus
K
• Core i5-520E
(2C/4T, 2.4 GHz, 3 MB cache,
TB, iAMT, VT), motherboard with
PROFIBUS/MPI
L
• Core i5-520E
(2C/4T; 2.4 GHz, 3 MB cache,
TB, iAMT, VT), motherboard with
PROFINET (3 x RJ45,
CP 1616-compatible)
2)
M
Core i7-610E (2C/4T, 2.53 GHz,
4 MB cache, TB, iAMT, VT),
motherboard without field bus
N
Core i7-610E (2C/4T, 2.53 GHz,
4 MB cache, TB, iAMT, VT),
motherboard with PROFIBUS/MPI
P
• Core i7-610E
(2C/4T; 2.53 GHz, 4 MB cache,
TB, iAMT, VT), motherboard with
PROFINET (3 x RJ45,
CP 1616-compatible)
2)
R
Hard disks:
250 GB HDD SATA; 0.5 g vibration,
5 g shock, internal A
500 GB HDD SATA; 0.5 g vibration,
5 g shock, internal B
2 x 500 GB HDD SATA; 0.5 g vibra-
tion, 5 g shock, internal C
RAID1 500 GB (2 x 250 GB HDD
SATA, mirror disks); 0.5 g vibration,
5 g shock, internal
D
250 GB HDD SATA in swap frame;
front H
500 GB HDD SATA in swap frame;
front K
2 x 500 GB HDD SATA in swap
frame; front M
RAID1 500 GB (2 x 250 GB HDD
SATA) in swap frame, for hot swap-
ping; front
P
50 GB SSD (SLC) SATA, internal S
50 GB SSD (SLC) SATA in swap
frame; front T
RAID1 1 TB (2 x 1 TB HDD SAS) in
swap frame, for hot-swapping,
front; PCIe x8 RAID controller with
zero-maintenance cache protec-
tion module in PCIe x16 slot
3)
U
1)
For an up-to-date overview, see the SIMATIC PC online configurator at:
www.siemens.com/ipc-configurator
2)
Not in combination with Windows Server operating systems.
3)
Not in combination with graphics card, Windows XP, Windows 7 (32-bit),
without removable media.
SIMATIC IPC647C
1)
(continued) 6AG4112- 1
7777-7 7 7 7
Memory configuration:
• 1 GB DDR3 SDRAM (1 x 1 GB),
single channel 0
• 2 GB DDR3 SDRAM (1 x 2 GB),
single channel 1
• 4 GB DDR3 SDRAM (2 x 2 GB),
dual channel 2
• 6 GB DDR3 SDRAM
(1 x 2 GB, 1 x 4 GB), dual channel 3
• 8 GB DDR3 SDRAM (2 x 4 GB),
dual channel 4
• 2 GB DDR3 SDRAM (2 x 1 GB),
dual channel 5
• 4 GB DDR3 SDRAM (2 x 2 GB),
dual channel 6
• 8 GB DDR3 SDRAM (2 x 4 GB),
dual channel 7
Swap media:
• CompactFlash drive, at front 0
•DVD±RW 1
• without swap medium 8
Bus module / hardware expansion
• Bus modules 3 slots: 2 x PCI;
1 x PCIe x16; without hardware
expansions
0
• Bus modules 3 slots: 2 x PCI;
1 x PCIe x16; DVI-VGA adapter
(1 x VGA) for onboard graphics
1
• Bus modules 3 slots: 2 x PCI;
1 x PCIe x16 assigned; + graphics
card PCIe x16, 2 x DP (2 x DVI-D
via 2 x DP-DVI adapters)
2
• Bus modules 3 slots: 2 x PCI;
1 x PCIe x16 assigned; + graphics
card PCIe x16, 2 x DP (2 x VGA via
2 x DP-VGA adapters)
3
• Bus modules 3 slots: 1 x PCI,
1 x PCIe x8 (4-lane); 1 x PCIe x16;
without HW expansions
4
• Bus modules 3 slots: 1 x PCI;
1 x PCIe x8 (4-lane); 1 x PCIe x16;
DVI-VGA adapter (1 x VGA) for on-
board graphics
5
• Bus modules 3 slots: 1 x PCI;
1 x PCIe x8 (4-lane); 1 x PCIe x16
assigned; + graphics card
PCIe x16, 2 x DP (2x DVI-D via
2x DP-DVI adapters)
6
• Bus modules 3 slots: 1 x PCI;
1 x PCIe x8 (4-lane); 1 x PCIe x16
assigned; + graphics card
PCIe x16, 2 x DP (2x VGA via
2x DP-VGA adapters)
7
ST80_2013_EN_Kap05.book Seite 17 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC647C
5/18 Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
5
Note:
Software Packages with SIMATIC WinCC flexible, WinCC RT
Advanced, SIMATIC WinCC, and SIMATIC WinAC RTX (F) can
be ordered together with the SIMATIC IPC at favorable prices.
More information under "Embedded bundles / Packages for
industrial PCs".
SIMATIC IPC647C
1)
(continued) 6AG4112- 1
7 7 7 7 -7777
Operating system
(preinstalled and activated)
• Windows XP Professional, MUI
(Eng, Ger, Fr, It, Sp), SP3, 32-bit B
Windows 7 Ultimate, MUI (Eng,
Ger, Fr, It, Sp), 32-bit, SP1 included E
Windows 7 Ultimate, MUI (Eng,
Ger, Fr, It, Sp), 64-bit, SP1 included F
Windows Server 2003 R2 Standard
Edition incl. 5 clients, MUI (Eng, Fr,
Ger, It, Sp), SP2, 32-bit, SP2
N
• Windows Server 2008 Standard
Edition incl. 5 clients, MUI
(Eng, Fr, Ger, It, Sp), SP2, 32-bit
P
Windows Server 2008 R2 Standard
Edition incl. 5 clients, MUI (Eng, Fr,
Ger, It, Sp), SP2, 64-bit, SP1 in-
cluded
Q
Without operating system X
Expansion (software)
SIMATIC IPC DiagMonitor 4.3
included A
SIMATIC IPC Image Creator
software 3.2 included B
SIMATIC IPC DiagMonitor 4.3
and Image Creator Software 3.2
included
C
Without software X
Power supply, with country-specific
cable:
• 100/240°V°AC industrial power
supply with Namur; power cable
for Europe
0
100/240 V AC industrial power
supply with Namur; power cable
for United Kingdom
1
100/240 V AC industrial power
supply with Namur; power cable
for Switzerland
2
100/240 V AC industrial power
supply with Namur; power cable
for USA
3
100/240 V AC industrial power
supply with Namur; power cable
for Italy
4
100/240 V AC industrial power
supply with Namur; power cable
for China
5
100/240 V AC redundant power
supply with Namur; without power
cable
6
1)
For an up-to-date overview, see the SIMATIC PC online configurator at:
www.siemens.com/ipc-configurator
Accessories
Memory expansion
• 1 GB DDR3 1066 SDRAM, DIMM 6ES7648-2AJ40-0KA0
• 2 GB DDR3 1066 SDRAM, DIMM 6ES7648-2AJ50-0KA0
• 4 GB DDR3 1066 SDRAM, DIMM 6ES7648-2AJ60-0KA0
• 1 GB DDR3 1066 SDRAM, DIMM,
ECC 6ES7648-2AJ40-1KA0
• 2 GB DDR3 1066 SDRAM, DIMM,
ECC 6ES7648-2AJ50-1KA0
• 4 GB DDR3 1066 SDRAM, DIMM,
ECC 6ES7648-2AJ60-1KA0
Hard disk slide-in unit
for swap frame 6ES7648-0EG00-1BA0
SIMATIC PC accessories, slide-in
HDD swap frame, low-profile, for
3.5" hard disk, serial ATA / SAS
(without hard disk)
Filter mats A5E02396171
for SIMATIC IPC647C
(packing unit: 10 units)
Power cable, straight, 3 m long
• Austria, Belgium, Finland, France,
Germany, Netherlands, Spain,
Sweden
6ES7900-0AA00-0XA0
• United Kingdom 6ES7900-0BA00-0XA0
• Switzerland 6ES7900-0CA00-0XA0
•USA 6ES7900-0DA00-0XA0
•Italy 6ES7900-0EA00-0XA0
• China 6ES7900-0FA00-0XA0
USB retainer 6ES7648-1AA00-0XK0
for pin assignment of the internal
USB port
Expansion components From page 5/153
Communication products From page 5/186
RMOS real-time operating system From page 5/146
ST80_2013_EN_Kap05.book Seite 18 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC647C
5/19
Siemens ST 80 / ST PC · 2013
Dimensional drawings
All dimensions in mm. For mounting cut-out see technical speci-
fications.
The fixing screws of the telescopic rails should not project more
than 5 mm into the enclosure.
The enclosure is prepared for the following telescopic rails:
Rittal: Type 3659.180 for 600 mm cabinet /
Type RP 3659.190 for 800 mm cabinet
More information
Further information can be found in the Internet under:
http://www.siemens.com/simatic-pc
Technical data of the telescopic rails
Carrying capacity per pair, min. 30 kg
Full extension length, min. 470 mm
Rail thickness, max. 9.7 mm
Fixing screws M5 x 6 mm
8.2
481.4
429.9
76.2
87.6
5.7
444.6
487.1
465
G_ST80_XX_00453
ST80_2013_EN_Kap05.book Seite 19 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC847C
5/20 Siemens ST 80 / ST PC · 2013
5
Overview
The SIMATIC IPC847C is a very robust, high-performance indus-
trial PC in 19" rack design (4 HU) with excellent industrial
functionality.
It offers:
Maximum expandability
Extreme ruggedness
Intel Core i technology
Technical specifications
SIMATIC IPC847C
General features
Design 19" rack, 4 HU, externally painted
Processor • Intel Core i7-610E
( 2C/4T, 2.53 GHz, 4 MB Cache,
Turbo Boost, VT-d, iAMT, EM64T)
Intel Core i5-520E
(2C/4T, 2.4 GHz, 3 MB cache,
Turbo Boost, VT-d, iAMT, EM64T)
Intel Core i3-330E
(2C/4T, 2.13 GHz, 3 MB cache,
EM64T)
Chipset Intel QM57
Main memory from 1 GB DDR3 1066 SDRAM
• Dual channel support
2 DIMM slots
Expandable up to 8 GB
1)
Spare slots for expansions (all long) 7 x PCI
• 1 x PCI Express x16
• 3 x PCI Express x4
or
7 x PCI
• 1 x PCI Express x16
Graphics • Onboard Intel GMA HD graphics
controller integrated into proces-
sor; dynamic video memory; up to
2048 x 1536 pixels with 75 Hz
refresh rate and 16-bit colors
PCI Express graphics card
(Dual Head: 2 x VGA or 2 x DVI-D
via display port adapter) in the
PCIe x16 slot; 256 MB; up to
2048 x 1536 pixels with 75 Hz
refresh rate and 32-bit colors
(optional)
1)
Memory information:
In order to use a memory with more than 4 GB, a 64-bit operating system is
required. In the case of configurations with 4 GB, the visible memory can
be reduced to about 3.5 GB or less (with 32-bit operating systems).
In configurations with 8 GB, the visible memory can be reduced to about
7.5 GB or less.
ST80_2013_EN_Kap05.book Seite 20 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC847C
5/21
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
Operating system without
Preinstalled and activated /
supplied on restore DVD
Windows XP Professional MUI,
32-bit
• Windows 7 Ultimate MUI,
32/64-bit
Windows Server 2003 R2
incl. 5 client MUI, 32-bit
Windows Server 2008 incl.
5 client MUI, 32-bit
Windows Server 2008 R2
incl. 5 client MUI, 64-bit
MUI: Multi-language User Interface;
5 languages (English, French,
German, Italian, Spanish)
Project-specific on request
• Linux
2)
•Other
Power supply 100 ... 240 V AC, 50 ... 60 Hz
with bridging of temporary power
failures in accordance with
NAMUR: max. 20 ms at
0.85% rated voltage
Redundant 100 ... 240 V AC,
50 ... 60 Hz
Drives
Hard disks SATA 3.5" or SAS 3.5" Installation in internal drive cage
•250 GB
Can be installed in internal shock
and vibration-damped drive cage
(optional)
•250 GB
•500GB
•2x 500GB
•500 GB RAID1
3)
,
(2 x 500 GB, mirror disks)
Installation in front drive cage in
swap frame
•250 GB
•2x 500GB
•500 GB RAID1
3)
,
(2 x 500 GB, mirror disks),
"hot swap"
1 TB RAID5
3)
, (3 x 500 GB,
striping with parity), "hot swap"
1 TB RAID1, (2 x 1 TB, mirror
disks), "hot swap"; PCIe x8 RAID
controller in PCIe x16 slot
1.8 TB RAID5, (3 x 1 TB, striping
with parity), "hot swap"; controller
with zero-maintenance cache pro-
tection module in PCIe x16 slot
• 50 GB SATA solid-state drive
(SLC)
Solid-State Drive (SSD) (2.5" SATA) Installed internally or front-mounted
in removable frame
50 GB (SLC), optional
DVD-ROM, 5.25", SATA 16 x (DVD media)
48 x (CD media)
DVD+/-R/RW, 5.25", SATA 16 x 16 x 12 x (DVD media)
48 x 32 x 48 x (CD media)
Floppy disk -
Slots for drives Front:
3 x 5.25" and 2 x 3.5"
Internal:
2 x 3.5" (in the optional,
vibration-damping drive cage)
SIMATIC IPC847C
Interfaces
PROFINET 3x RJ45 (CP 1616-compatible),
optional
PROFIBUS/MPI 12 Mbit/s (isolated, compatible
with CP 5611), optional
Ethernet 2 x 10/100/1000 Mbit/s
(RJ45, teaming-capable)
USB 2.0 • 2 x front (high current)
4 x rear (high current)
• 1 x internal (high current),
e.g. for USB dongle
Serial • 9-pin COM1 (V.24)
• 9-pin COM2 (V.24)
Parallel LPT1
VGA 1x
Keyboard PS/2
Mouse PS/2
Audio 1 x Line Out; 1 x Micro
2)
Suitable for specific LINUX versions in accordance with the specifications
of the Siemens manufacturer's declaration "Suitable for LINUX", see
http://www.siemens.com/simatic-pc/suited-for-linux
(LINUX is a trademark of Linus Torvald).
3)
SATA RAID controller on board in Intel chipset
SIMATIC IPC847C
ST80_2013_EN_Kap05.book Seite 21 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC847C
5/22 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
5
Monitoring functions
Basic functionality Message locally
via DiagBase software
Temperature • Overshoot/undershoot of permis-
sible operating temperature range
Messages can be evaluated by
the application program
Fan Speed monitoring
2 x enclosure fans
• 1 x fan power supply
Watchdog • Monitoring of program execution
Monitoring time can be parame-
terized in software
Restart can be parameterized in
the event of a fault
Messages can be evaluated by
the application program
Monitoring functions via the network SIMATIC PC DiagMonitor (optional)
Remote monitoring capability for:
• Watchdog
•Temperature
•Fan speed
• Hard disk monitoring (SMART)
System/Ethernet monitoring
(Heart Beat)
Communication:
Ethernet interface
(SNMP protocol)
OPC for integration
in SIMATIC software
Configuration of
client/server architectures
Structure of log files
Front LEDs POWER (internal power supply
unit, PC switched on)
HARDDISK (access to hard disk)
• ETHERNET1
(Ethernet status, "Heartbeat")
• ETHERNET2 (Ethernet status,
"Heartbeat")
PN / MPI/DP
(PROFINET/PROFIBUS status)
• WATCHDOG
(ready/fault indication)
TEMP (temperature status)
FAN (fan speed monitoring)
HDD1 ALARM (hard disk alarm in
conjunction with RAID and moni-
toring software)
HDD2 ALARM (hard disk alarm in
conjunction with RAID and moni-
toring software)
HDD3 ALARM (hard disk alarm in
conjunction with RAID and moni-
toring software)
SIMATIC IPC847C
Ambient conditions
Degree of protection IP41 at the front, IP20 at the rear
acc. to EN 60529
Dust protection With front door closed: G2 EN 779,
99% of particles > 0.5 mm are held
back
Protection class Protection class I in accordance
with IEC 61140
Vibration load during operation DIN EN 60068-2-6, 10 cycles
Internal mounting of the hard disk
drives in optional, internal drive
cage:
10 ... 58 Hz: 0.0375 mm
58 ... 500 Hz: 5 m/s
2
(approx. 0.5 g)
Permanently installed internal hard
disk drives:
10 ... 58 Hz: 0.019 mm
58 ... 500 Hz: 3 m/s
2
(approx. 0.3 g)
Note:
There are limitations when
DVD+/-RW and HDD are operated
in a swap frame
Shock loading during operation DIN EN 60068-2-27,
IEC 60068-2-29
Internal mounting of the hard disk
drives in optional, internal drive
cage:
Half-sine: 50 m/s
2
, 30 ms
(approx. 5 g), 100 shocks
per axis
• Permanently installed internal
hard disk drives: 30 m/s
2
,
30 ms (approx. 3 g)
Note:
There are limitations when
DVD+/-RW and HDD are operated
in a swap frame
SIMATIC IPC847C
ST80_2013_EN_Kap05.book Seite 22 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC847C
5/23
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
Note regarding SIMATIC PC operating system licenses
The accompanying operating system license is only valid for
installation on the respective supplied SIMATIC IPC. Installation
can only be performed on these SIMATIC systems in accor-
dance with Microsoft OEM licensing regulations.
Electromagnetic compatibility (EMC)
Emitted interference (AC) EN 61000-6-3 FCC Class A
EN 61000-3-2 Class D and
EN 61000-3-3
Immunity to conducted interference
on the supply lines ± 2 kV (IEC 61000-4-4, burst)
± 1 kV
(IEC 61000-4-5, symm. surge)
± 2 kV
(IEC 61000-4-5, asymm. surge)
Immunity to interference on signal lines ± 1 kV (IEC 61000-4-4, burst,
length < 30 m)
± 2 kV (IEC 61000-4-4, symm.
surge, length > 30 m)
± 2 kV (IEC 61000-4-5, asymm.
surge, length > 30 m)
Immunity to static discharge ±6 kV, contact discharge
(IEC 61000-4-2)
±8 kV, air discharge
(IEC 61000-4-2)
Immunity to high radio frequency
interference 1 V/m 80% AM; 2-2.7 GHz
(IEC 61000-4-3)
10 V/m 80% AM; 80 MHz to
1 GHz and 1.4 GHz and 2 GHz
(IEC 61000-4-3);
10 V, 10 kHz to 80 MHz
(IEC 61000-4-6)
Immunity to magnetic fields 100 A/m, 50/60 Hz (IEC 61000-4-8)
Ambient temperature
during operation 5...50 °C
Note:
There are limitations when using
DVD-ROM / DVD+/-RW and SAS
HDD in swap frames
Relative operating humidity 5 ... 80% at 25 °C
(no condensation)
Approvals and safety regulations
Safety regulations IEC 60950-1 Second Edition,
EN 60950-1:2006,
UL 60950-1 Second Edition
CSA C22.2 No 60950-1-07
Second Edition
Approvals cULus 60950-1 Second Edition,
KCC
CE mark • Emitted interference:
EN 61000-6-3:2007
• Noise immunity:
EN 61000-6-2:2005
Dimensions and weights
Mounting dimensions
(W x H x D, in mm) 430 x 177 x 448
SIMATIC IPC847C
ST80_2013_EN_Kap05.book Seite 23 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC847C
5/24 Siemens ST 80 / ST PC · 2013
5
Ordering data
Order No. Order No.
SIMATIC IPC847C
1)
6AG4114- 1
7 7 7 7 -7 7 7 7
Interfaces: 2 x 10/100/1000 Mbps
Ethernet (RJ45);
1 x graphic (DVI-I); 2 x COM;
1 x LPT; 2 x PS/2;
4 x USB 2.0 at rear,
2 x USB 2.0 at front,
1x USB 2.0 internal; audio;
temperature and fan monitoring,
watchdog;
Processor, motherboard:
• Core i3-330E
(2C/4T, 2.13 GHz, 3 MB cache),
motherboard without fieldbus
G
• Core i3-330E
(2C/4T, 2.13 GHz, 3 MB cache),
motherboard with PROFIBUS/MPI
H
• Core i3-330E
(2C/4T; 2.13 GHz, 3 MB cache),
motherboard with PROFINET
(3 x RJ45, CP 1616-compatible)
2)
J
• Core i5-520E
(2C/4T, 2.4 GHz, 3 MB cache,
TB, iAMT, VT), motherboard
without fieldbus
K
• Core i5-520E
(2C/4T, 2.4 GHz, 3 MB cache,
TB, iAMT, VT), motherboard
with PROFIBUS/MPI
L
• Core i5-520E
(2C/4T; 2.4 GHz, 3 MB cache,
TB, iAMT, VT), motherboard
with PROFINET (3 x RJ45,
CP 1616-compatible)
2)
M
• Core i7-610E
(2C/4T, 2.53 GHz, 4 MB cache,
TB, iAMT, VT), motherboard
without field bus
N
Core i7-610E (2C/4T, 2.53 GHz,
4 MB cache, TB, iAMT, VT),
motherboard with PROFIBUS/MPI
P
• Core i7-610E
(2C/4T; 2.53 GHz, 4 MB cache,
TB, iAMT, VT), motherboard
with PROFINET (3 x RJ45,
CP 1616-compatible)
2)
R
SIMATIC IPC847C
1)
(continued) 6AG4114- 1
7777-7 7 7 7
Hard disks:
250 GB HDD SATA; 0.5 g vibration,
5 g shock, internal A
500 GB HDD SATA; 0.5 g vibration,
5 g shock, internal B
2 x 500 GB HDD SATA; 0.5 g vibra-
tion, 5 g shock, internal C
• RAID1 500 GB (2 x 500 GB HDD
SATA, mirror disks); 0.5 g vibration,
5 g shock, internal
D
250 GB HDD SATA; 0.3 g vibration,
3 g shock, internal G
250 GB HDD SATA in swap frame;
front H
500 GB HDD SATA in swap frame;
front K
• 2 x 500 GB HDD SATA in swap
frame; front M
• RAID1 500 GB
(2 x 500 GB HDD SATA) in swap
frame, for hot swapping; front
P
• RAID5 1 TB
(3 x 500 GB HDD SATA) in swap
frame, for hot swapping; front
R
• 50 GB SSD (SLC) SATA, internal S
• 50 GB SSD (SLC) SATA in swap
frame; front T
• RAID1 1 TB (2 x 1 TB HDD SAS)
in swap frame, for hot-swapping,
front; PCIe x8 RAID controller with
zero-maintenance cache protec-
tion module in PCIe x16 slot
3)
U
RAID5 1.8 TB (3 x 1 TB HDD SAS)
in swap frame, for hot-swapping,
front; PCIe x8 RAID controller with
zero-maintenance cache protec-
tion module in PCIe x16 slot
3)
V
Memory configuration:
• 1 GB DDR3 SDRAM
(1 x 1 GB), single channel 0
• 2 GB DDR3 SDRAM
(1 x 2 GB), single channel 1
• 4 GB DDR3 SDRAM
(2 x 2 GB), dual channel 2
• 6 GB DDR3 SDRAM
(1 x 2 GB, 1 x 4 GB), dual channel 3
• 8 GB DDR3 SDRAM
(2 x 4 GB), dual channel 4
• 2 GB DDR3 SDRAM
(2 x 1 GB), dual channel 5
• 4 GB DDR3 SDRAM
(2 x 2 GB), dual channel 6
• 8 GB DDR3 SDRAM
(2 x 4 GB), dual channel 7
1)
For an up-to-date overview, see the SIMATIC PC online configurator at:
www.siemens.com/ipc-configurator
2)
Not in combination with Windows Server 2008 R2, Windows Server 2008
and Windows Server 2003 R2
3)
Not in combination with graphics card, Windows XP, Windows 7 (32-bit),
without removable media.
ST80_2013_EN_Kap05.book Seite 24 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC847C
5/25
Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
SIMATIC IPC847C
1)
(continued) 6AG4114- 1
7 7 7 7 -7 7 7 7
Swap media:
•DVD-ROM 1
•DVD+/-RW 2
Without swap medium 8
Bus module / hardware expansion
Bus module, 8 slots:
7 x PCI, 1 x PCIe x16;
without hardware expansions
0
Bus module, 8 slots:
7 x PCI; 1x PCIe x16;
DVI-VGA adapter (1 x VGA)
for onboard graphics
1
Bus module, 8 slots:
7x PCI; 1x PCIe x16 assigned;
+ graphics card PCIe x16, 2 x DP
(2x DVI-D via 2x DP-DVI adapters)
2
Bus module, 8 slots:
7x PCI; 1x PCIe x16 assigned;
+ graphics card PCIe x16, 2 x DP
(2x VGA via 2x DP-VGA adapters)
3
Bus module, 11 slots:
7xPCI, 1xPCIe x16, 3xPCIe x4;
without hardware expansions
4
Bus module, 11 slots:
7x PCI, 1x PCIe x16, 3x PCIe x4;
+ DVI-VGA adapter (VGA) for
onboard graphics
5
Bus module, 11 slots:
7x PCI; 1x PCIe x16 assigned,
3x PCIe x4; + graphics card
PCIe x16, 2 x DP (2x DVI-D via
2x DP-DVI adapters)
6
Bus module, 11 slots:
7x PCI; 1x PCIe x16 assigned;
3x PCIe x4; + graphics card
PCIe x16, 2x DP (2x VGA via
2x DP-VGA adapters)
7
SIMATIC IPC847C
1)
(continued) 6AG4114- 1
7 7 7 7 -7777
Operating system
(preinstalled and activated)
• Windows XP Professional, MUI
(Eng, Ger, Fr, It, Sp), 32-bit, SP3 B
• Windows 7 Ultimate, MUI (Eng,
Ger, Fr, It, Sp), 32-bit, SP1 included E
• Windows 7 Ultimate, MUI (Eng,
Ger, Fr, It, Sp), 64-bit, SP1 included F
Windows Server 2003 R2 Standard
Edition incl. 5 clients, MUI
(Eng, Fr, Ger, It, Sp), 32-bit, SP2
N
• Windows Server 2008 Standard
Edition incl. 5 clients, MUI
(Eng, Ger, Fr, It, Sp), 32-bit, SP2
P
Windows Server 2008 R2 Standard
Edition incl. 5 clients, MUI
(Eng, Ger, Fr, It, Sp), 64-bit, SP1
enclosed
Q
• Without operating system X
Software expansion
• SIMATIC IPC DiagMonitor 4.3
included A
• SIMATIC IPC Image Creator
software 3.2 included B
• SIMATIC IPC DiagMonitor 4.3 &
Image Creator software 3.2
included
C
• Without software X
Power supply,
country-specific cable
• 100/240 V AC industrial power
supply with Namur; power cable
for Europe
0
• 100/240 V AC industrial power
supply with Namur; power cable
for United Kingdom
1
• 100/240 V AC industrial power
supply with Namur; power cable
for Switzerland
2
• 100/240 V AC industrial power
supply with Namur; power cable
for USA
3
• 100/240 V AC industrial power
supply with Namur; power cable
for Italy
4
• 100/240 V AC industrial power
supply with Namur; power cable
for China
5
100/240 V AC industrial redundant
power supply unit with Namur;
without power cable
6
1)
For an up-to-date overview, see the SIMATIC PC online configurator at:
http://www.siemens.com/ipc-configurator
ST80_2013_EN_Kap05.book Seite 25 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Rack PC
SIMATIC IPC847C
5/26 Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
5
Note:
Software Packages with SIMATIC WinCC flexible, WinCC RT
Advanced, SIMATIC WinCC, and SIMATIC WinAC RTX (F) can
be ordered together with the SIMATIC IPC at favorable prices.
More information under "Embedded Bundles / Packages for
industrial PCs".
Dimensional drawings
All dimensions in mm. For mounting cut-out see technical speci-
fications.
The fixing screws of the telescopic rails should not project more
than 5 mm into the enclosure.
The enclosure is prepared for the following telescopic rails:
Rittal: Type 3659.180 for 600 mm cabinet /
Type RP 3659.190 for 800 mm cabinet
Schroff: Type 20110-072
More information
Further information can be found in the Internet under:
http://www.siemens.com/simatic-pc
Accessories
Memory expansion
1 GB DDR3 1066 SDRAM, DIMM 6ES7648-2AJ40-0KA0
2 GB DDR3 1066 SDRAM, DIMM 6ES7648-2AJ50-0KA0
4 GB DDR3 1066 SDRAM, DIMM 6ES7648-2AJ60-0KA0
1 GB DDR3 1066 SDRAM, DIMM,
ECC 6ES7648-2AJ40-1KA0
2 GB DDR3 1066 SDRAM, DIMM,
ECC 6ES7648-2AJ50-1KA0
4 GB DDR3 1066 SDRAM, DIMM,
ECC 6ES7648-2AJ60-1KA0
Hard disk slide-in unit
for swap frame 6ES7648-0EG00-1BA0
SIMATIC PC accessories,
slide-in unit for low-profile HDD
swap frame, for 3.5" hard disk,
SATA / SAS (without hard disk)
Filter mats A5E01064980
For Rack PC 847B and IPC847C
Packing unit 10 units
Power cable, straight, 3 m long
• Austria, Belgium, Finland, France,
Germany, Netherlands, Spain,
Sweden
6ES7900-0AA00-0XA0
• United Kingdom 6ES7900-0BA00-0XA0
• Switzerland 6ES7900-0CA00-0XA0
•USA 6ES7900-0DA00-0XA0
•Italy 6ES7900-0EA00-0XA0
• China 6ES7900-0FA00-0XA0
Tower Kit
for converting the computer into an
industrial tower PC 6ES7648-1AA00-0XD0
Retainer 6ES7648-1AA00-0XK0
for pin assignment of the internal
USB port
Expansion components From page 5/153
Communication products From page 5/186
RMOS real-time operating system From page 5/146
*B67B;;B
492
430
448
481.4
465.1
176.5
101.6
Technical data of the telescopic rails
Carrying capacity per pair, min. 30 kg
Full extension length, min. 470 mm
Rail thickness, max. 9.7 mm
Fixing screws M5 x 6 mm
ST80_2013_EN_Kap05.book Seite 26 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Box PC
Box PC
5/27
Siemens ST 80 / ST PC · 2013
Overview
SIMATIC Box PCs provide mechanical engineers, plant
engineers and control cabinet makers with particularly rugged
industrial PC systems for use in powerful yet compact applica-
tions.
The following device classes are available for various require-
ments:
SIMATIC IPC227 (Nanobox PC):
The compact embedded IPC – maintenance-free and
dust-proof with versatile mounting
SIMATIC IPC427 (Microbox PC):
The powerful embedded IPC – maintenance-free with
versatile configuration
SIMATIC IPC627/IPC827 (Box PC):
The high-end IPC – with maximum performance, functional
scope, and expansion capability
Shared industrial functionality:
Extreme compactness
Certification for global marketing
System-tested with SIMATIC components
High vibration/shock load during operation
Wide operational temperature range
Robust data storage with CompactFlash/CFast or Solid-State
Drive (SSD)
Integrated PROFIBUS or PROFIBUS/MPI interface (optional)
Varied mounting possibilities for flexibility with installation
Designed for 24-hour continuous operation
Integrated parameterizable monitoring functions
(temperature, fan, watchdog)
High service friendliness
Operating system preinstalled and activated for fast startup
Motherboard developed and manufactured by Siemens
Availability for 3 to 6 years
Repairs and spare parts service for 5 years
High continuity of the components/design
Installation and software compatible with predecessor model
Long-term availability of PC components from the Intel
embedded line
SIMATIC IPC227 (Nanobox PC):
The compact embedded IPC – maintenance-free and dust-
proof with versatile mounting
Maximum compactness with approx. 1 liter enclosure volume
with integrated industrial power supply for minimum space
requirements in the control cabinet
Maximum flexibility thanks four mounting options and inter-
faces on one side suitable for every installation situation
Optimum variety of interfaces due to a large number of
integrated interfaces such as selectable serial ports
(RS 232/RS 485/CAN) and 2 x teaming-capable Gigabit LAN
Maximum industrial functionality due to closed enclosure for
optimum dust protection and non-volatile retentive memory
Further device options for optimum adaptation to the
application with additional PCIe slot or RS 232 interfaces
or digital I/O
ST80_2013_EN_Kap05.book Seite 27 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Box PC
Box PC
5/28 Siemens ST 80 / ST PC · 2013
Overview (continued)
5
SIMATIC IPC427 (Microbox PC):
The powerful embedded IPC – maintenance-free with
versatile configuration
Fan-free operation
High performance with maximum compactness and
ruggedness for direct installation in the machine
Optimized for embedded applications
Flexibility expandable using one or two PCIe I/O cards
(optional)
Flexible installation options due to DIN rail/wall/front upright
mounting, even outside a control cabinet
NVRAM for retentive data storage (optional)
SIMATIC IPC627/IPC827 (Box PC):
The high-end IPC – with maximum performance, functional
scope, and expansion capability
Maximum system performance for complex measuring,
control and visualization tasks
High flexibility with expansion slots and integral interfaces
Flexible, space-saving installation with mounting brackets or
portrait assembly kits
Rugged design for direct installation in the machine
RAID1 controller onboard
Maximum processor performance up to ambient temperature
of 55 °C
High system availability
Battery-backed SRAM as memory for WinAC data
2 x 7-segment display and 2 signal LEDs
(freely programmable)
SIMATIC IPC227D
(Nanobox PC) SIMATIC IPC427D
(Microbox PC) SIMATIC IPC427C
(Microbox PC) SIMATIC IPC627C
(Box PC) SIMATIC IPC827C
(Box PC)
Design
Rail or wall mounting - -
Wall or portrait mounting • Also: Side mounting
General features
Processor • Intel Atom E620
600 MHz
• Intel Atom E640
1.0 GHz
• Intel Atom E660
1.3 GHz
Intel Core i7-
3517UE, 1.7 GHz,
4 MB SLC
Intel Core i3-
3217UE, 1.6 GHz,
3 MB SLC
Intel Celeron 827E
1.4 GHz, 1.5 MB
SLC
Intel Core2 Duo
1.2 GHz, 800 MHz
FSB, 3 MB SLC
Intel Core2 Solo
1.2 GHz, 800 MHz
FSB, 3 MB SLC
Intel Celeron M
1.2 GHz, 800 MHz
FSB, 1 MB SLC
• Intel Core i7-620E,
2.53 GHz, 2 cores,
4 threads, 4 MB
cache, TB, HT, VT-x,
VT-d
• Intel Core i3-330E,
2.13 GHz, 2 cores,
4 threads, 3 MB
cache, HT, VT-x
Intel Celeron P4505,
1.86 GHz, 2 cores,
2 MB cache
Intel Core i7-620E,
2.53 GHz, 2 cores,
4 threads, TB, HT,
VT-x, VT-d, AMT 4
MB cache
Intel Core i3-330E,
2.13 GHz, 2 cores,
4 threads, HT, VT-x,
3 MB cache
Intel Celeron P4505,
1.86 GHz, 2 cores,
2 MB cache
Main memory 512 MB, 1 GB, 2 GB 1 GB, 2 GB, 4 GB,
8GB 1 GB, 2 GB, 4 GB 1 GB, expandable up
to 8 GB,
optional ECC
1 GB, expandable up
to 8 GB,
optional ECC
Static RAM 512 KB 512 KB 2MB 2MB 2MB
Free slots for expansions 1 x PCIe with PCIe
enclosure option Up to 2 x PCIe
(enclosure option) Up to 3 x PCI-104
(with expansion frame) 2 x PCI or
1 x PCI-Express x16 /
1x PCI
(175 mm / 265 mm)
3x PCI
(290/290/240 mm),
1 PCI-Express x
(185 mm)
1 x PCI-Express x16
(240 mm)
Graphics Onboard Onboard Onboard Onboard Onboard
ST80_2013_EN_Kap05.book Seite 28 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Box PC
Box PC
5/29
Siemens ST 80 / ST PC · 2013
Overview (continued)
• Available
- Not available
1)
Suitable for specific Linux versions in accordance with the specifications of
the Siemens manufacturer's declaration "Suitable for Linux", see
http://www.siemens.com/simatic-pc/suited-for-linux
(Linux is a trademark of Linus Torvald).
More information
Further information can be found on the Internet at:
http://www.siemens.com/simatic-pc
Information material can be ordered or downloaded from the
Internet:
http://www.siemens.com/simatic/printmaterial
Operating system
without • •
Preinstalled and activated / supplied
on restore CD Windows Embed-
ded Standard 2009
(CF card 2 GB,
SSD, hard disk)
• Windows XP Profes-
sional MUI (SSD,
hard disk)
• Windows Embed-
ded Standard 7,
32 bit
(CF card 4 GB,
SSD, hard disk)
• Windows 7 Ultimate
MUI, 32 bit (SSD,
hard disk)
• Windows 7
Ultimate MUI
• Windows Embed-
ded Standard 7 in
combination with
CF card 4GB,
solid-state drive,
or hard drive
Windows Embedded
Standard 2009, in
combination with CF
card 2 GB, solid-
state drive, or hard
drive
Windows XP Profes-
sional Multi-Lan-
guage; in combination
with solid-state drive
or hard drive
Windows 7 Ultimate
MUI
Windows Embedded
Standard 7
• Windows XP
Professional MUI
Windows 7 Ultimate
32-bit MUI
Windows 7 Ultimate
64-bit MUI
• Windows Embed-
ded Standard 2009
English on 8 GB
CompactFlash
• Windows XP
Professional MUI
Windows 7 Ultimate
32-bit MUI
Windows 7 Ultimate
64-bit MUI
• Windows Embed-
ded Standard 2009
English on 8 GB
CompactFlash
Order separately RMOS3 V3.50 RMOS3 V3.50 RMOS3 V3.50 RMOS3 V3.50 RMOS3 V3.50
Project-specific on request •Linux
1)
• Other Linux
1)
•Other Linux
1)
•Other •Linux
1)
• Other Linux
1)
•Other
Interfaces
PROFINET onboard -3 x RJ45 (CP 1616
compatible)
onboard, optional
3 x RJ45 (CP 1616
compatible) onboard,
optional
3xRJ45(CP1616
compatible) onboard,
optional
3 x RJ45 (CP 1616
compatible) onboard,
optional
PROFIBUS/MPI -12 Mbps (compati-
ble with CP 5622),
optional
12 Mbps (CP 5611-
compatible), optional 12 Mbps (CP 5611-
compatible) onboard,
optional
12 Mbps (CP 5611-
compatible) onboard,
optional
Ethernet 2 x 10/100/
1000 Mbps 2 x 10/100/
1000 Mbps 2 x 10/100/1000 Mbps 2 x 10/100/
1000 Mbps 1 x 10/100/
1000 Mbps
USB 2.0 (high current) 4x 4x USB 3.0 4x 4x 4x
VGA, LVDS, DVI, DPP 1 x DVI-D 1 x DVI-I
(DVI and VGA)
1 x DisplayPort
1 x DVI-I
(DVI and VGA) 1x DVI-I
(DVI and VGA) 1 x DVI-I
(DVI and VGA)
Drives
Hard disks 1 x 2.5" (optional) 1 x 2.5" (optional) 1 x 2.5" (optional) 1 x 3.5"
• 2 x 2.5"
• RAID1/2 x 2.5"
•1x3.5"
•2x2.5"
RAID1/2 x 2.5"
Solid-state drive 1 x 2.5" SATA
(optional) 1 x 2.5" SATA
(optional) 1 x 2.5" SATA (optional) 1 x 2.5" SATA
(optional) 1 x 2.5" SATA
(optional)
FlashDrive 1 x CF externally
accessible 1 x CFast exter-
nally accessible
1 x CFast internal,
in place of HDD,
SSD (optional)
• 1 x CF externally
accessible
• 1 x CF internal, in
place of HDD, SSD
(optional)
• 1 x CF at the front,
externally accessi-
ble
• 1 x CF internal, in
place of HDD
(optional)
1 x CF at the front,
externally accessible
Optical drives - - - DVD R/W DVD R/W
Ambient conditions
Vibration/shock load during operation 1g / 15g
(with FlashDrive) 1 g / 15 g
(with FlashDrive) 1g / 15g
(with FlashDrive) 1g / 5g 1g / 5g
Ambient temperature
during operation 0 °C … 50 °C
(with FlashDrive)
0 °C … 40 °C
(with hard disk)
With maximum
configuration:
0... 50/5C
(with FlashDrive)
5 ... 40 ºC
(with hard disk)
With maximum
configuration:
0 ... 50/55 ºC
(with FlashDrive)
5 ... 40 ºC
(with hard disk)
With maximum
configuration:
5 ... 45 °C
5 ... 50/55 °C
(with 20/10 W load on
PCI/PCI-Express bus)
With maximum
configuration:
5 ... 45 °C
5 ... 50/55 °C
(with 20/10 W load on
PCI/PCI-Express bus)
SIMATIC IPC227D
(Nanobox PC) SIMATIC IPC427D
(Microbox PC) SIMATIC IPC427C
(Microbox PC) SIMATIC IPC627C
(Box PC) SIMATIC IPC827C
(Box PC)
ST80_2013_EN_Kap05.book Seite 29 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC227D
5/30 Siemens ST 80 / ST PC · 2013
5
Overview
SIMATIC IPC227D (Nanobox PC):
The compact embedded IPC – maintenance-free and
dust-proof with versatile mounting
Maximum compactness with approx. 1 liter enclosure volume
or more with integrated industrial power supply for minimum
space requirements in the control cabinet
Maximum flexibility thanks four mounting options and inter-
faces on one side suitable for every installation situation
Optimum variety of interfaces due to a large number of
integrated interfaces such as a selectable serial port
(RS 232/RS 485/CAN) and 2 x teaming-capable Gigabit LAN
Maximum industrial functionality due to closed enclosure for
optimum dust protection and non-volatile retentive memory
Further device options for optimum adaptation to the appli-
cation with additional PCIe slot or R S232 interfaces or
digital I/O
Technical specifications
SIMATIC IPC227D
General features
Design Rail, wall, portrait or side mounting
Processor • Intel Atom E620 600 MHz,
512 MB RAM
Intel Atom E640 1.0 GHz,
1 GB RAM
Intel Atom E660 1.3 GHz,
2 GB RAM
Chipset Intel Controller Hub EG20T
Buffered MRAM optional, 512 KB, of which 128 KB
can be written within the buffer time
Free slots for expansions Optional PCIe expansion slot
Graphics Integrated into Intel Atom CPU E6xx
8 to 256 MB (shared memory),
1920 x 1200, 60 Hz, 32-bit colors
Operating system • Without
• Windows Embedded Standard
2009 preinstalled, in combination
with CF card or solid-state drive or
hard drive (optional)
Windows XP Professional MUI prein-
stalled (in combination with solid-
state drive or hard drive; MUI: Multi
Language User Interface) (optional)
• Windows Embedded Standard 7,
32-bit, preinstalled, in combination
with CF card or solid-state drive or
hard drive (optional)
Windows 7 Ultimate MUI 32 bit pre-
installed (in combination with solid-
state drive or hard drive; MUI: Multi
Language User Interface) (optional)
•Linux
1)
(project-specific, on request)
RMOS (project-specific on request)
• Others on request project-specifi-
cally
Design Rail, wall, portrait or side mounting
Power supply 24VDC (20.4V ... 28.8V)
•Isolated
With buffering of temporary power
failures: max. 10 ms
Line side switch
• With power failure indication by
means of Power Fail signal
1)
Suitable for specific LINUX versions in accordance with the specifications
of the Siemens manufacturer's declaration "Suitable for LINUX", see
http://www.siemens.com/simatic-pc/suited-for-linux
(LINUX is a trademark of Linus Torvald).
ST80_2013_EN_Kap05.book Seite 30 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC227D
5/31
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
Drives
Flash drive Optional; replaceable, accessible,
diagnosable
•2GB
•4 GB
•8GB
•16GB
Solid-state drive (SSD) Optional
50 GB SATA, High Endurance, 2.5"
80 GB SATA, Standard, 2.5"
Hard disk Optional
•250GB SATA
CD-ROM Via USB
(not included in scope of delivery)
DVD-RW Via USB
(not included in scope of delivery)
Floppy disk Via USB
(not included in scope of delivery)
Interfaces
PROFINET PROFINET RT via Standard Ethernet
controller
PROFIBUS/MPI -
Ethernet 2 x 10/100/1000 Mbps (RJ 45)
Two independent Intel Controllers:
Intel 82574L / Intel Controller Hub
EG20T
• With teaming function
USB V2.0: 4 x
Serial COM1 (V.24), optional COM2-4
DVI-I 1 x DVI-D
Keyboard Via USB (not included in scope of
delivery)
Mouse Via USB (not included in scope of
delivery)
SIMATIC IPC227D
Monitoring functions
Temperature • Processor temperature
• Motherboard
Messages can be evaluated by the
application program
Watchdog Monitoring of program execution
• Monitoring time can be parameter-
ized in software
Can be parameterized for a fault or
restart
Messages can be evaluated by the
application program
Monitoring functions via the network DiagBase
SIMATIC IPC DiagMonitor
Remote monitoring capability for:
• Watchdog
•Temperature
• Mass memory monitoring (SMART)
System/Ethernet monitoring
(Heart Beat)
• Runtime meter
Communication:
Ethernet interface (SNMP protocol)
OPC for integration in
SIMATIC software
Configuration of client/server archi-
tectures
Structure of log files
Ambient conditions
Degree of protection to EN 60529
(front/rear) IP40
Vibration load during operation Devices without hard disk:
Requirements according to:
IEC 61131-2
Tested according to:
IEC 60068-2-6, Test Fc
• 10-58: 0.0375 mm
58-200: 9.8 m/s
2
• 10 x /axis
Devices with hard disk:
Requirements according to:
IEC 61131-2
Tested according to:
IEC 60068-2-6, Test Fc
• 10-58: 0.0375 mm
58-200: 4.9 m/s
2
• 10 x /axis
Shock loading during operation Devices without hard disk:
Requirements according to:
IEC 61131-2
Tested according to:
IEC 60068-2-27, Test Ea
•150m/s
2
, 30 ms shock duration
Devices with hard disk:
Requirements according to:
IEC 61131-2
Tested according to:
IEC 60068-2-27, Test Ea
50 m/s
2
, 30 ms shock duration
Moist heat With CompactFlash card/SSD: 95 %
With hard disk: 80 %
Ambient temperature
during operation 0 °C up to 50 °C
SIMATIC IPC227D
ST80_2013_EN_Kap05.book Seite 31 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC227D
5/32 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
5
Release for individual order variants: See releases in the
ordering procedure.
Electromagnetic compatibility
(EMC)
Emitted interference EN 55022 Class B
Interference immunity, burst EN 61000-6-2 or IEC 61131-2:
2 kV - tested acc. to IEC 61000-4-4
• 1 kV symmetrical / 2 kV asymmetri-
cal - tested acc. to IEC 61000-4-5
Interference immunity, surge 1 kV to IEC 61000-4-5; symmetrical
2 kV to IEC 61000-4-5; asymmetri-
cal
ESD interference immunity According to NAMUR Recommenda-
tion NE 21 and EN 61000-6-2:
6 kV contact discharge - tested acc.
to IEC 61000-4-2
8 kV air discharge - tested acc. to
IEC 61000-4-2
Immunity to high radio frequency
interference According to EN 61000-6-2 or
IEC 61131-2:
Interference immunity 80 ... 1000
MHz: 10 V/m with 80% AM (1 kHz);
tested acc. to IEC 61000-4-3;
1.4 GHz ... 2 Hz: 10 V/m with 50%
pulse modulation; tested according
to IEC 61000-4-3
Immunity to high-frequency current
feed Acc. to NAMUR Recommendation
NE 21 and EN 61000-6-2 or
IEC 61131-2:
10 kHz ... 80 MHz: 10 V
with 80% AM (1 kHz)
tested acc. to IEC 61000-4-6
Immunity to magnetic fields Acc. to NAMUR Recommendation
NE 21 and EN 61000-6-2
or IEC 61131-2:
• 50/60 Hz; 100 A/m rms value -
tested acc. to IEC 61000-4-8
SIMATIC IPC227D
Approvals
Marine approval
Only for configurations with
CompactFlash or SSD memory
GL – Germanische Lloyd
•BV Bureau Veritas
• LR – Lloyds Register of Shipping
ABS – American Bureau of Shipping
DNV – Det Norske Veritas
• NKK – Nippon Kaiji Kyokai
Device versions
Basic version Width x Height x Depth:
approx. 191 x 100 x 60 mm
COM 3 additional, integrated
serial interfaces
(COM2-4);
only sending/receiving of data
Width x Height x Depth:
approx. 191 x 100 x 89 mm
IO 4 digital inputs/outputs each, 24 V,
integrated
Width x Height x Depth:
approx. 191 x 100 x 89 mm
PCIe • 1 PCIe (x1) slot, integrated
Width x Height x Depth:
approx. 191 x 187 x 89 mm
SIMATIC IPC227D
ST80_2013_EN_Kap05.book Seite 32 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC227D
5/33
Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
Release for individual order variants: See releases in the
ordering procedure.
SIMATIC IPC227D 6ES7647- 8 A
777-7 7 7 7
Atom E620 (600 MHz),
512 MB RAM,
without drive, with CF slot,
COM1: RS232, without operating
system,
device version: Base,
DIN rail,
1 x DVI-D graphics interface
2 x 10/100/1000 Mbps Ethernet
RJ45
4 x USB V2.0 (high current)
CompactFlash slot
24 V DC industrial power supply
Processors / memory configuration /
NVRAM
Atom E620 (600 MHz), 512 MB
RAM A
Atom E620 (600 MHz), 512 MB
RAM, NVRAM B
Atom E640 (1.0 GHz), 1 GB RAM E
Atom E640 (1.0 GHz), 1 GB RAM,
NVRAM F
Atom E660 (1.3 GHz), 2 GB RAM G
Atom E660 (1.3 GHz), 2 GB RAM,
NVRAM H
Drives
Without drive, with CF slot 0
250 GB HDD SATA 1
50 GB Solid-State Drive SATA
(High Endurance) 3
80 GB Solid-State Drive SATA
(Standard) 4
2 GB SIMATIC IPC CompactFlash 5
4 GB SIMATIC IPC CompactFlash 6
8 GB SIMATIC IPC CompactFlash 7
16 GB SIMATIC IPC CompactFlash 8
COM interface
COM1: RS232 0
COM1: RS485 1
•COM1: CAN 2
Operating system
Without operating system 0
• Windows Embedded Standard
2009 preinstalled
(CF from 2 GB/SSD/HD)
1
• XP Prof. MUI preinstalled
on SSD/HD 2
• Windows Embedded Standard 7
(32-bit) preinstalled
(CF from 4 GB/SSD/HD)
3
• Windows 7 (32-bit) MUI
preinstalled on SSD/HD 4
SIMATIC IPC227D 6ES7647- 8 A
7 7 7 -7777
Software bundles
• Without RTX/HMI software A
• RTX: WinAC RTX 2010 B
• RTX-F: WinAC RTX F 2010 C
• HMI: WinCC RT Advanced 128 PT F
• HMI: WinCC RT Advanced 512 PT G
• HMI: WinCC RT Advanced
2048 PT H
HMI/RTX: RT 128 PT M
HMI/RTX: RT 512 PT N
HMI/RTX: RT 2048 PT P
• HMI/RTX-F: RT 128 PT R
• HMI/RTX-F: RT 512 PT S
• HMI/RTX-F: RT 2048 PT T
Device versions
• Device version: Base line A
• Device version: PCIe (1 slot) B
• Device version: COM
(COM2-4: RS232) D
• Device version: IO
(4x dig. in/out each) E
Mounting accessories
• Standard mounting rail 1
• Wall mounting 2
• Portrait mounting 3
• Side mounting 4
Accessories
Cable strain relief set for IPC227D 6ES7648-1AA50-0XL0
Packing unit: 5 units
Dust protection set for IPC227D 6ES7648-1AA50-0XG0
ST80_2013_EN_Kap05.book Seite 33 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC227D
5/34 Siemens ST 80 / ST PC · 2013
5
Dimensional drawings
All dimensions in mm. For mounting cut-out see technical specifications.
SIMATIC IPC227D basic unit, portrait mounting
SIMATIC IPC227D basic unit, standard rail mounting
SIMATIC IPC227D COM version, portrait mounting
SIMATIC IPC227D COM version, standard rail mounting
4.8
21.5
231.5
G_ST80_XX_00474
46
19
28
15
220
197
62
60
100
105
2
8.5
G_ST80_XX_00464
100
60
50


76.6
4.8
14.5
231.5
20.3
93.1
2.5
90.6
G_ST80_XX_00475
56
198
220
21
100
105
90.6
8.5
G_ST80_XX_00465
50


100
ST80_2013_EN_Kap05.book Seite 34 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC227D
5/35
Siemens ST 80 / ST PC · 2013
Dimensional drawings (continued)
SIMATIC IPC227D PCIe version, portrait mounting
SIMATIC IPC227D PCIe version, standard rail mounting
76.6
20.3
4.8
231.5
14.5
2.5
93.1
90.6
G_ST80_XX_00476
56
220
21
198
187
192
90.6
93.5
8.5
G_ST80_XX_00473


167
More information
Further information can be found on the Internet at:
http://www.siemens.com/simatic-pc
ST80_2013_EN_Kap05.book Seite 35 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC427D
5/36 Siemens ST 80 / ST PC · 2013
5
Overview
SIMATIC IPC427D (Microbox PC):
The powerful embedded IPC – maintenance-free
with versatile configuration
Ready-to-run, complete solutions (software is already installed
and preconfigured) for visualization and automation in
connection with WinCC RT Advanced and/or WinAC RTX:
• Ultra-compact
• Maintenance-free
Third generation Intel Core i technology
Technical specifications
SIMATIC IPC427D
General features
Design • DIN rail mounting
Wall mounting
Portrait mounting
Processor • Intel Celeron 827E 1.4 GHz,
1.5 MB SLC
Intel Core i3-3217UE 1.6 GHz,
3 MB SLC
Intel Core i7-3517UE 1.7 GHz,
4 MB SLC
Main memory Memory module without ECC:
1 GB DDR3-SDRAM SODIMM
2 GB DDR3-SDRAM SODIMM
4 GB DDR3-SDRAM SODIMM
8 GB DDR3-SDRAM SODIMM
Memory module with ECC:
• 4 GB DDR3-ECC SODIMM
• 8 GB DDR3-ECC SODIMM
Free slots for expansions Up to 2 x PCIe cards, depending on
enclosure design
Graphics • Integrated Intel HD2000 or HD4000
DVI resolution of 640 x 480 pixels up
to 1920 x 1200 pixels
Maximum display port resolution
1920 x 1200 pixels
Graphics memory is occupied in the
main memory (UMA dynamic)
Power supply 24 V DC (-20%/+20%) max. 4 A
Rated conditions Fan-free operation
Operating systems
Available • without
• Windows Embedded Standard 7
• Windows 7 Ultimate MUI
Project-specific • Linux
•QNX
• VxWorks
Drives and storage media
CFast card 2 GB optional or
4 GB optional or
8 GB optional or
• 16 GB optional
Hard disk • 2.5", 1 x 250 GB, SATA
Solid-state drive (SSD) •1 x 50 GB, 2.5" SATA-SSD,
high endurance or
•1 x 80 GB, 2.5" SATA-SSD,
standard or
•1 x 160 GB, 2.5" SATA-SSD,
standard
USB stick External, can be connected
via USB port
Interfaces
Serial • COM1 (RS 232)
• COM2 (RS 232); optional
Graphics • DVI-I: Can be used as DVI or VGA
DPP++: Display port, DVI via
DPP-to-DVI adapter
USB 4 x USB 3.0, max. 2 high-current at
the same time, downward-compatible
with USB 2.0/1.1
Ethernet 2 x RJ45 (10/100/1000 Mbps)
teaming-capable or
• 1 x RJ45 (10/100/1000 Mbps)
with PROFINET versions
PROFIBUS DP 12 Mbps (isolated, compatible with
CP 5622), optional
PROFINET 3 x RJ45 (10/100 Mbps),
CP 1616 onboard, optional
CAN interface Optional
Keyboard, mouse Connection via USB port
Advanced device functions
Temperature • When permitted operating
temperature range is exceeded
Warnings can be analyzed by the
application program (local, via LAN)
Watchdog Monitoring function for program
execution
Restart can be parameterized in the
event of a fault
Warnings can be analyzed by the
application program (local, via LAN)
LED display 4 LEDs for displaying system status,
3 of these can be programmed by the
user
Short-term voltage dip Up to 15 ms buffer time at full load
Buffer memory 512 KB MRAM optional
SIMATIC IPC427D
ST80_2013_EN_Kap05.book Seite 36 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC427D
5/37
Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
1)
"Built to order" – versions with a delivery time of max. 15 working days and
with identified repair, if not preferred type.
2)
For an up-to-date overview, see the SIMATIC PC online configurator at:
www.siemens.com/ipc-configurator
3)
Only with "main memory and NVRAM".
Note:
Bundles with SIMATIC software only with Windows Embedded
Standard 7, main memory and NVRAM (with RTX and RTX F),
and CFast mass storage of 4 GB or more / SSD.
SIMATIC IPC427D (Box PC)
1) 2)
6AG4140-
77777-7777
Processor and fieldbus:
Celeron U827E
(1C/1T, 1.4 GHz, 1.5 MB cache);
2 x Gigabit Ethernet (IE/PN)
0
Celeron U827E
(1C/1T, 1.4 GHz, 1.5 MB cache);
2 x Gigabit Ethernet (IE/PN);
PROFIBUS DP12
1
Celeron U827E
(1C/1T, 1.4 GHz, 1.5 MB cache);
2 x Gigabit Ethernet (IE/PN);
CAN interface
2
• Core i3-3217UE
(2C/4T, 1.6 GHz, 3 MB cache);
2 x Gigabit Ethernet (IE/PN)
3
• Core i3-3217UE
(2C/4T, 1.6 GHz,3 MB cache);
2 x Gigabit Ethernet (IE/PN);
PROFIBUS DP12
4
• Core i3-3217UE
(2C/4T, 1.6 GHz, 3 MB cache);
1 x Gigabit Ethernet (IE/PN);
1 x PROFINET (IRT, 3 ports)
5
• Core i7-3517UE
(2C/4T, 1.7 (2.8) GHz,
3 MB cache); 2 x Gigabit Ethernet
(IE/PN) (optional ECC only here)
6
• Core i7-3517UE
(2C/4T, 1.7 (2.8) GHz, 3 MB
cache); 2 x Gigabit Ethernet
(IE/PN); PROFIBUS DP12
7
• Core i7-3517UE
(2C/4T, 1.7 (2.8) GHz, 3 MB
cache); 1 x Gigabit Ethernet
(IE/PN); 1 x PROFINET
(IRT, 3 ports)
8
Mounting accessories:
DIN rail mounting B
Wall mounting D
Portrait mounting E
Work memory/NVRAM/ECC:
•1 GB A
•2 GB B
•4 GB C
•8 GB D
4 GB with ECC (only with Core i7,
2 x Gigabit Ethernet (IE/PN)) G
8 GB with ECC (only with Core i7,
2 x Gigabit Ethernet (IE/PN)) H
1 GB and NVRAM J
2 GB and NVRAM K
4 GB and NVRAM L
8 GB and NVRAM M
4 GB with ECC and NVRAM (only
with Core i7, 2 x Gigabit Ethernet
(IE/PN))
N
8 GB with ECC and NVRAM (only
with Core i7, 2 x Gigabit Ethernet
(IE/PN))
P
Expansions/interface:
• One RS 232, without PCIe 0
• One RS 232 and one PCIe 1
• One RS 232 and two PCIe 2
Second RS 232, without PCIe 3
• Second RS 232 and one PCIe 4
• Second RS 232 and second PCIe 5
Operating system:
Without operating system 0
• Windows Embedded Standard 7
SP1, English, 32-bit 4
• Windows 7 Ultimate SP1, 32-bit,
MUI (Eng, Ger, Fr, It, Sp) 6
• Windows 7 Ultimate SP1, 64-bit,
MUI (Eng, Ger, Fr, It, Sp) 7
SIMATIC IPC427D (Box PC)
1) 2)
(continued) 6AG4140-
77777-7777
Mass storage, externally accessible:
• Without external mass storage 0
• CFast 2 GB
Without operating system 1
• CFast 4 GB
(only optionally with operating sys-
tem if no internal mass storage)
2
• CFast 8 GB
(only optionally with operating sys-
tem if no internal mass storage)
3
• CFast 16 GB
(only optionally with operating sys-
tem if no internal mass storage)
4
Internal mass storage:
• Without internal mass storage A
• CFast 2 GB, without software B
• CFast 4 GB, without software C
• CFast 8 GB, without software D
• CFast 16 GB, without software E
• SSD 50 GB high endurance (SLC) G
• SSD 80 GB Standard H
• HDD 250 GB K
• SSD 160 GB Standard P
SIMATIC software preinstalled
(bundles, only with Windows
Embedded Standard 7):
• Without SIMATIC software A
• WinAC RTX 2010
3)
B
• WinCC RT Advanced, 128 PT C
• WinCC RT Advanced, 512 PT D
• WinCC RT Advanced, 2048 PT E
• WinCC RT Advanced, 4096 PT F
• WinCC RT Advanced 128 PT,
WinAC RTX 2010
3)
J
• WinCC RT Advanced 512 PT,
WinAC RTX 2010
3)
K
• WinCC RT Advanced 2048 PT,
WinAC RTX 2010
3)
L
• WinCC RT Advanced 4096 PT,
WinAC RTX 2010
3)
M
• WinAC RTX F 2010
3)
N
• WinCC RT Advanced 128 PT,
WinAC RTX F 2010
3)
P
• WinCC RT Advanced 512 PT,
WinAC RTX F 2010
3)
Q
• WinCC RT Advanced 2048 PT,
WinAC RTX F 2010
3)
R
• WinCC RT Advanced 4096 PT,
WinAC RTX F 2010
3)
S
Power supply:
•24VDC
industrial power supply 0
• 24 V DC and TPM
(not for China and Russia) 8
ST80_2013_EN_Kap05.book Seite 37 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC427D
5/38 Siemens ST 80 / ST PC · 2013
5
Dimensional drawings
All dimensions in mm. For mounting cut-out see technical specifications.
SIMATIC IPC427D, DIN rail mounting SIMATIC IPC427D, wall mounting
SIMATIC IPC427D, portrait mounting
83.76.7 1.5
50.5
G_ST80_XX_00553
133
9
G
5050
184
262
Ø 4.5
1.5
16.5 50.5
6.7
16.5
G_ST80_XX_00554
133
85
100 10
2
262
G
286
297
6.1
2.5
55.5
61.5
15.3
21.5
8.9
5.8
G_ST80_XX_00555
G
25
143
300
315
272
ST80_2013_EN_Kap05.book Seite 38 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC427C
5/39
Siemens ST 80 / ST PC · 2013
Overview
SIMATIC IPC427C (Microbox PC): The powerful embedded
IPC – maintenance-free with versatile configuration
• Ultra-compact
• Maintenance-free
Intel Core2 Duo technology
Technical specifications
SIMATIC IPC427C
General features
Design DIN rail or wall mounting, front upright
mounting, mounting position prefera-
bly horizontal, vertical possible
Processor • Intel Core2 Duo 1.2 GHz,
800 MHz FSB, 3 MB SLC
Intel Core2 Solo 1.2 GHz,
800 MHz FSB, 3 MB SLC
Intel Celeron M 1.2 GHz,
800 MHz FSB, 1 MB SLC
Chipset Intel GM45 / ICH9M
Main memory 1 GB, (2/4 GB) DDR3 SDRAM
Buffered SRAM 2 MB, of which 128 KB can be written
within the buffer time
Free slots for expansions Up to 3 x PCI-104, 3 W per slot
Graphics • Integrated Intel GMAX4500
graphics
8 ... 512 MB shared graphics mem-
ory (managed dynamically)
CRT resolution: 640 x 480 pixels
up to max. 1920 x 1200 pixels at
32 bit colors
DVI-D resolution: 640 x 480 pixels
up to max. 1920 x 1200 pixels at
32 bit colors
Operating system • Without
Windows XP Embedded Standard
2009 preinstalled, in combination
with CF card of 2 GB or more,
solid-state drive, or hard drive
Windows XP Professional MUI
(in combination with solid-state
drive or hard drive; MUI:
Multi Language User Interface)
Windows 7 Ultimate MUI (in combi-
nation with solid-state drive or hard
drive; MUI: Multi Language User
Interface)
• Windows Embedded Standard 7
preinstalled, in combination with CF
card of 4 GB or more, or solid-sate
drive, or hard drive RMOS3 (can be
ordered separately)
•Linux
1)
(project-specific, on request)
• Others on request project-specifi-
cally
Power supply 24 V DC (19.2 V ... 28.8 V)
•Isolated
With buffering of temporary power
failures: Max. 10 ms at 0.85% rated
voltage
Line side switch
• With power failure indication by
means of Power Fail signal
1)
Suitable for specific LINUX versions in accordance with the specifications
of the Siemens manufacturer's declaration "Suitable for LINUX", see
http://www.siemens.com/simatic-pc/suited-for-linux
(LINUX is a trademark of Linus Torvald).
ST80_2013_EN_Kap05.book Seite 39 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC427C
5/40 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
5
Drives
Flash drive Optional; replaceable, accessible,
diagnosable
•2GB
•4GB
•8GB
•16GB
Optional; internal, not accessible,
diagnosable
•2GB
•4GB
•8GB
•16GB
Solid-State Drive (SSD) Optional
50 GB SATA, 2.5" in single-level cell
(SLC) architecture (High Endur-
ance), especially suitable for
industrial applications
80 GB SATA, 2.5" Standard
Hard disk Optional
> 250 GB SATA
CD-ROM Via USB
(not included in scope of delivery)
DVD-RW Via USB
(not included in scope of delivery)
Diskette Via USB
(not included in scope of delivery)
Interfaces
PROFINET 3 x RJ45
(CP 1616-compatible, optional)
PROFIBUS/MPI 12 Mbit/s
(isolated, compatible to CP 5611)
optional
Ethernet 2 x 10/100/1000 Mbit/s (RJ 45)
Two independent Intel 82574L
controllers (via PCI-Express)
One controller with none-shared
interrupt
• With teaming function
USB V2.0/High Speed: 4 x
Serial COM1 (V.24)
COM2 (V.24) optional
(in expansion frame)
DVI-I 1 x DVI-I (includes DVI-D and VGA)
Keyboard Via USB
(not included in scope of delivery)
Mouse Via USB
(not included in scope of delivery)
SIMATIC IPC427C
Monitoring functions
Temperature • Processor temperature
• Motherboard
Messages can be evaluated by the
application program
Watchdog Monitoring of program execution
• Monitoring time can be parameter-
ized in software
Can be parameterized for a fault or
restart
Messages can be evaluated by the
application program.
Monitoring functions via the network • DiagBase
SIMATIC IPC DiagMonitor
Remote monitoring capability for:
• Watchdog
•Temperature
• Mass memory monitoring (SMART)
System/Ethernet monitoring
(Heart Beat)
• Runtime meter
Communication:
Ethernet interface (SNMP protocol)
OPC for integration in
SIMATIC software
Configuration of client/server
architectures
Layout of log files
Ambient conditions
Degree of protection to EN 60529
(front/rear) IP20
Vibration load during operation Devices without hard disk:
Requirements according to:
IEC 61131-2
Tested according to:
IEC 60068-2-6, Test Fc
Devices without drive:
- 5-9 Hz, 3.5 mm deviation,
10x /axis, 1 octave/min
- 9-150 Hz, 9.8 m/s
2
, 10x /axis,
1 octave/min
Devices with hard disk:
Wall mounting
Requirements according to:
IEC 61131-2
Tested according to:
IEC 60068-2-6, Test Fc
10 ... 58 Hz, 0.0375 mm deviation,
10x /axis, 1 octave/min
58 ... 200 Hz, 4.9 m/s
2
, 10x /axis,
1 octave/min
Shock loading during operation Devices without hard disk:
Requirements according to:
IEC 61131-2
Tested according to:
IEC 60068-2-27, Test Ea
Module/rack: 150 m/s
2
, power-up,
11 ms shock duration
Devices with hard disk:
Wall mounting
Requirements according to:
IEC 61131-2
Tested according to:
IEC 60068-2-27, Test Ea
Devices with drive: 50 m/s
2
,
power-up, 30 ms shock duration
SIMATIC IPC427C
ST80_2013_EN_Kap05.book Seite 40 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC427C
5/41
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
Electromagnetic compatibility
(EMC)
Emitted interference EN 55022 Class B
Interference immunity, burst EN 61000-6-2 or IEC 61131-2:
2 kV - Tested acc. to IEC 61000-4-4
• 1 kV symmetrical / 2 kV asymmetri-
cal - Tested acc. to IEC 61000-4-5
Interference immunity, surge 1 kV to IEC 61000-4-5; symmetrical
2 kV to IEC 61000-4-5; asymmetrical
• ESD interference immunity According to NAMUR Recommenda-
tion NE 21 and EN 61000-6-2:
• 6 kV contact discharge -
Tested acc. to IEC 61000-4-2
• 8 kV air discharge -
Tested acc. to IEC 61000-4-2
Immunity to high radio frequency
interference According to EN 61000-6-2 or
IEC 61131-2:
Interference immunity
80 ... 1000 MHz: 10 V/m with
80% AM (1 kHz); tested acc. to
IEC 61000-4-3;
1.4 GHz ... 2 Hz: 10 V/m with 50%
pulse modulation; tested according
to IEC 61000-4-3
• Immunity to high-frequency
current feed Acc. to NAMUR Recommendation
NE 21 and EN 61000-6-2 or
IEC 61131-2:
• 10 kHz ... 80 MHz:
10 V with 80% AM (1 kHz)
tested acc. to IEC 61000-4-6
Immunity to magnetic fields Acc. to NAMUR Recommendation
NE 21 and EN 61000-6-2 or
IEC 61131-2:
50/60 Hz; 100 A/m rms value
- tested acc. to IEC 61000-4-8
Ambient temperature
during operation 0 ... 55 ºC with flash drive/SSD
(horizontal; preferred mounting
position; with derating)
0 ... 50 ºC with flash drive/SSD
(horizontal; preferred mounting
position; maximum configuration)
0 ... 50 ºC with flash drive/SSD
(vertical)
5 ... 40 ºC with hard disk
(horizontal and vertical)
Moist heat With CompactFlash card/SSD: 95 %
With hard drive 80%
SIMATIC IPC427C
System-tested
SIMATIC Industrial Software WinAC RTX (F), WinCC flexible,
WinCC (SCADA as of V7.0), WinCC
RT Advanced and Professional
Approvals UL508, UL60950, cULus
Marine approval
Only for configurations with
CompactFlash or SSD memory
• GL - Germanische Lloyd
BV - Bureau Veritas
LR - Lloyds Register of Shipping
• ABS - American Bureau of Shipping
• DNV - Det Norske Veritas
NKK - Nippon Kaiji Kyokai
Safety regulations • IEC 61131-2
IEC 61010-1
• EN 60950-1
CE mark • EC Directive 89/336/EEC
(EMC Directive)
Use in industry:
• Applications in residential areas,
business and trade environments as
well as in workshops:
- Emitted interference:
EN 61000-6-4
- Noise immunity: EN 61000-6-2
• Applications in residential areas,
business and trade environments as
well as in workshops:
- Emitted interference:
EN 61000-6-3
- Noise immunity: EN 61000-6-1
Dimensions and weights
Equipment dimensions (in mm) Width x height: 262 x 134
Depth of basic unit: 47
Depth of basic unit above rail: 50
Additional depth per expansion
(1-3): 17 each
Weight, approx. 2 kg
SIMATIC IPC427C
ST80_2013_EN_Kap05.book Seite 41 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC427C
5/42 Siemens ST 80 / ST PC · 2013
5
Ordering data
Order No. Order No.
Note:
Ready-to-use SIMATIC IPC427C as bundles can be found
under "Embedded Bundles".
Software packages with SIMATIC WinCC flexible, SIMATIC
WinCC RT Advanced, SIMATIC WinCC, SIMATIC WinCC RT
Professional and SIMATIC WinAC RTX (F) can be ordered
together with the SIMATIC IPC with a price advantage.
SIMATIC IPC427C
1)
6ES7647- 7 B
777
-
777
0
Intel Celeron M 1.2 GHz, 800 MHz
FSB, SLC 0 KB; 512 MB DDR3
RAM; without HD; without flash
drive; without operating system;
24 V DC industrial power supply
Processor:
• Intel Celeron M 1.2 GHz,
800 MHz FSB A
• Intel Celeron M 1.2 GHz,
800 MHz FSB, PROFIBUS B
• Intel Celeron M 1.2 GHz,
800 MHz FSB, CAN D
• Core2 Solo 1.2 GHz,
800 MHz FSB SLC, 3 MB E
Core2 Solo 1.2 GHz, 800 MHz FSB
SLC, 3 MB, PROFIBUS F
Core2 Solo 1.2 GHz, 800 MHz FSB
SLC, 3 MB, PROFINET G
Core2 Duo 1.2 GHz, 800 MHz FSB
SLC, 3 MB J
Core2 Duo 1.2 GHz, 800 MHz FSB
SLC, 3 MB, PROFIBUS K
Core2 Duo 1.2 GHz, 800 MHz FSB
SLC, 3 MB, PROFINET L
Memory configuration:
1 GB DDR3 1066, SODIMM 2
2 GB DDR3 1066, SODIMM 3
4 GB DDR3 1066, SODIMM 4
Expansion (HW):
No expansion (HW) 0
• Second RS232 interface
in expansion rack 1
Drives exchangeable (accessible)
Without drive 0
2 GB CompactFlash 2
4 GB CompactFlash 3
8 GB CompactFlash 4
16 GB CompactFlash 5
Drives internal (not accessible)
Without internal drive X
250 GB HDD SATA A
• 50 GB SSD High Endurance SATA D
80 GB Standard SATA E
2 GB CompactFlash internal N
4 GB CompactFlash internal P
8 GB CompactFlash internal Q
• 16 GB CompactFlash internal R
Operating system
(preinstalled and activated)
2)
Without operating system 0 X
• Windows Embedded Standard
2009 English preinstalled on inter-
nal drive
0 A
• Windows XP Professional MUI,
SP3 (Eng, Ger, Fr, It, Sp) prein-
stalled on internal drive
0 B
• Windows Embedded Standard 7
preinstalled on internal drive 0 C
Windows 7 Ultimate, 32-bit, MUI
(Eng, Ger, Fr, It, Sp) preinstalled on
internal drive
0 D
1)
For an up-to-date overview, see the SIMATIC PC online configurator at:
www.siemens.com/ipc-configurator
2)
XP Embedded on 2 GB CompactFlash or hard disk.
XP Professional or Windows 7 only with hard disk/SSD.
Accessories
Memory expansion
• 1 GB DDR3 1066 SDRAM,
SODIMM 6ES7648-2AH40-0KA0
• 2 GB DDR3 1066 SDRAM,
SODIMM 6ES7648-2AH50-0KA0
• 4 GB DDR3 1066 SDRAM,
SODIMM 6ES7648-2AH60-0KA0
Expansion kit PC/104 6AG4070-0BA00-0XA0
For integration of PC/104 modules in
the SIMATIC Microbox PC; packing
unit contains 6 expansion frames
SIMATIC PC adapter cable 6ES7648-3AB00-0XA0
DVI-I acc. to VGA, 250 mm
SIMATIC PC DVI-I Y graphics
adapter cable 6ES7648-3AE00-0XA0
DVI-I to VGA and DVI-D
Portrait assembly kit 6ES7648-1AA20-0YB0
Interfaces to the front
Expansion components From page 5/153
Communication products From page 5/186
For power supplies and
uninterruptible power supplies From page 5/170
RMOS3 real-time operating
system From page 5/146
ST80_2013_EN_Kap05.book Seite 42 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC427C
5/43
Siemens ST 80 / ST PC · 2013
Dimensional drawings
All dimensions in mm. For mounting cut-out see technical specifications.
SIMATIC IPC427Cb SIMATIC IPC427C, interfaces
More information
Further information can be found in the Internet under:
http://www.siemens.com/simatic-pc
46.5
*B67B;;B
133
138
262
G_ST80_XX_00456
262 138
52.5
97.5
ST80_2013_EN_Kap05.book Seite 43 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC627C
5/44 Siemens ST 80 / ST PC · 2013
5
Overview
SIMATIC IPC627C (Box PC):
The high-end IPC – with maximum performance,
functional scope and expansion capability
It offers:
Maximum performance in the smallest space
Intel Core i7 technology
Technical specifications
SIMATIC IPC627C
Supply voltage
Supply voltage 100 - 240 V AC, optional 24 V
Processor
Processor Core i7-610E (2C/4T, 2.53 GHz,
TB, HT, VT, AMT, 4MB cache);
Core i3-330E (2C/4T, 2.13 GHz, HT,
VT, 3MB cache); Celeron P4505
(2C/2T, 1.86 GHz, VT, 2MB cache);
Interfaces
PROFIBUS/MPI Onboard, isolated, max. 12 Mbit/s,
CP5611-compatible
USB port 4x USB 2.0 high speed/high current
Free slots 2 X PCI or 1xPCI & 1 x PCIe X16
(265 mm/185mm long) , 1xslot for
CompactFlash Card
Connection for keyboard/mouse USB / USB
serial interface COM1: 1 x V.24 (RS232)
Video interfaces
•Graphics interface DVI-I: VGA / DVI combined
Industrial Ethernet
• Industrial Ethernet interface 2 x Fast Ethernet
Monitoring functions
Temperature Yes
Watchdog Yes
Status LEDs Yes
Standards, approvals, certificates
Approval CE, cULus (508), C-Tick
EMC CE, EN 55022A, EN 61000-6-4,
EN 61000-6-2
Ambient conditions
Relative humidity
• Relative humidity Tested to DIN IEC 68-2-3,
DIN IEC 68-2-30,
DIN IEC 68-2-56: 5% to 80%
at 25 °C (no condensation)
Vibrations
• Vibration load in operation Tested to DIN IEC 68-2-6:
10 to 58 Hz: 0.075 mm,
58 to 200 Hz: 9.8 m/s
2
(1 g)
Shock testing
• Shock loading in operation Tested to DIN IEC 68-2-29:
50 m/s
2
(5g), 30 ms, 100 shocks
Operating systems
Operating system Windows XP Prof. SP3, MUI;
Windows 7 Ultimate 32/64Bit, MUI;
Windows Embedded Standard 2009
English on 8 GB CompactFlash;
without operating system;
Software
SIMATIC Software Optionally in package with
SIMATIC WinCC or WinCC flexible
Dimensions
Width 312 mm
Height 80 mm; with DVD drive: 100 mm
Depth 301 mm; incl. mounting rail
ST80_2013_EN_Kap05.book Seite 44 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC627C
5/45
Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
1)
For an up-to-date overview, see the SIMATIC PC online configurator at:
www.siemens.com/ipc-configurator
SIMATIC IPC627C
1)
6ES7647- 6 C
777
-
7777
HD graphics on-board,
128 MB dyn. shared memory;
2 x 10/100/1000 Mbps Ethernet
RJ45; 4 x USB V2.0 (high current);
1 x serial (COM1), RAID controller
on-board;
CompactFlash drive no. 1 at front
(without CF);
watchdog, temp./fan monitoring;
Processor:
Celeron P4505 (2C/2T, 1.86 GHz,
VT, 2 MB cache) A
Celeron P4505 (2C/2T, 1.86 GHz,
VT, 2 MB cache), PROFIBUS/MPI
(CP5611-compatible),
2 MB battery-backed SRAM
B
Celeron P4505 (2C/2T, 1.86 GHz,
VT, 2 MB cache), PROFINET
(3 x RJ45, CP1616-compatible),
2 MB battery-backed SRAM
C
Core i3-330E (2C/4T, 2.13 GHz,
HT, VT, 3 MB cache) D
Core i3-330E (2C/4T, 2.13 GHz,
HT, VT, 3 MB cache),
PROFIBUS/MPI,
2 MB battery-backed SRAM
E
Core i3-330E (2C/4T, 2.13 GHz,
HT, VT, 3 MB cache), PROFINET
(3 x RJ45, CP1616-compatible),
2 MB battery-backed SRAM
F
Core i7-610E (2C/4T, 2.53 GHz,
TB, HT, VT, AMT, 4 MB cache) G
Core i7-610E (2C/4T, 2.53 GHz,
TB, HT, VT, AMT, 4 MB cache),
PROFIBUS/MPI,
2 MB battery-backed SRAM
H
Core i7-610E (2C/4T, 2.53 GHz,
TB, HT, VT, AMT, 4 MB cache),
PROFINET (3 x RJ45, CP1616-
compatible), 2 MB battery-backed
SRAM
J
Memory configuration
1 GB DDR3 1066 DIMM 0
2 GB DDR3 1066 DIMM 1
3 GB DDR3 1066 DIMM 2
4 GB DDR3 1066 DIMM 3
8 GB DDR3 1066 DIMM 4
2 GB DDR3 1066 DIMM, ECC 5
4 GB DDR3 1066 DIMM, ECC 6
8 GB DDR3 1066 DIMM, ECC 7
Country-specific version/
power supply
100/240 V AC industrial power
supply with Namur; European
cable
0
100/240 V AC industrial power
supply with Namur; UK cable 1
100/240 V AC industrial power
supply with Namur; Swiss cable 2
100/240 V AC industrial power
supply with Namur; USA cable 3
100/240 V AC industrial power
supply with Namur; Italian cable 4
100/240 V AC industrial power
supply with Namur; Chinese cable 5
24 V DC industrial power supply 6
Device Certification UL Class I
Div. 2; 24 V DC industrial
power supply
7
Device Certification UL Class I
Div. 2; 110 / 230 V AC Industrial
Power Supply with Namur
8
SIMATIC IPC627C
1)
(continued) 6ES7647- 6 C
7 7 7
-
7777
PC slots
• 2 x PCI free 0
• 1 x PCI, 1x PCIe (x16) free 1
Drives
• 250 GB HDD SATA A
• 250 GB HDD SATA; DVD+/-RW B
• 500 GB HDD SATA C
• 500 GB HDD SATA; DVD+/-RW D
• 2 x 250 GB SATA (2.5") E
• 2 x 250 GB SATA (2.5") +
DVD+/-RW F
• RAID1 2 x 250 GB SATA (2.5") G
• RAID1 2 x 250 GB SATA (2.5");
DVD+/-RW H
50 GB SATA solid-state drive (SLC) J
• 50 GB SATA solid-state drive
(SLC); DVD+/-RW K
• CompactFlash drive No. 2
installed, DVD+/-RW U
CompactFlash drive No. 2 installed V
•DVD+/-RW W
• Without drives X
Operating system
(preinstalled and activated)
• Windows XP Professional MUI,
SP3 (Eng, Ger, Fr, It, Sp) A
• Windows 7 Ultimate, MUI (Eng,
Ger, Fr, It, Sp), 32-bit, SP1 included B
• Windows 7 Ultimate, MUI (Eng,
Ger, Fr, It, Sp), 64-bit, SP1 included C
• Windows Embedded Standard
2009 English on 8 GB
CompactFlash
F
• Without operating system X
Expansion
• No expansion (software) 0
SIMATIC IPC DiagMonitor software
included 1
• SIMATIC IPC Image&Partition
Creator software included 2
• SIMATIC IPC DiagMonitor,
Image & Partition Creator software
included
3
ST80_2013_EN_Kap05.book Seite 45 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC627C
5/46 Siemens ST 80 / ST PC · 2013
5
Ordering data Order No.
Note:
Software Packages with SIMATIC WinCC flexible, WinCC RT
Advanced, SIMATIC WinCC, and SIMATIC WinAC RTX (F) can
be ordered together with the SIMATIC IPC at favorable prices.
More information under "Embedded Bundles / Packages for
industrial PCs".
Dimensional drawings
All dimensions in mm. For mounting cut-out see technical speci-
fications.
More information
Further information can be found in the Internet under:
http://www.siemens.com/simatic-pc
Accessories
Memory expansions
1 GB DDR3 1066, DIMM 6ES7648-2AJ40-0KA0
1 GB DDR3 1066, DIMM; ECC 6ES7648-2AJ40-1KA0
2 GB DDR3 1066, DIMM 6ES7648-2AJ50-0KA0
2 GB DDR3 1066, DIMM; ECC 6ES7648-2AJ50-1KA0
4 GB DDR3 1066, DIMM 6ES7648-2AJ60-0KA0
4 GB DDR3 1066, DIMM; ECC 6ES7648-2AJ60-1KA0
PCI expansion card
with COM1 and LPT 6ES7648-2CA01-0AA0
Graphics adapter cable
DVI-I acc. to VGA, 250 mm long 6ES7648-3AB00-0XA0
• DVI-I acc. to VGA and DVI-D,
250 mm long (Y cable) 6ES7648-3AE00-0XA0
Portrait assembly kit
Interfaces upward/downward 6ES7648-1AA10-0YA0
Interfaces to the front 6ES7648-1AA10-0YB0
SIMATIC PC,
230 V AC power cable
angled, 3 m for Box PC
and Panel PC for
Austria, Belgium, Finland, France,
Germany, Netherlands, Spain,
Sweden
6ES7900-1AA00-0XA0
United Kingdom 6ES7900-1BA00-0XA0
• Switzerland 6ES7900-1CA00-0XA0
•USA 6ES7900-1DA00-0XA0
•Italy 6ES7900-1EA00-0XA0
• China 6ES7900-1FA00-0XA0
Expansion components From page 5/153
Communication products From page 5/186
For power supplies and
uninterruptible power supplies From page 5/170
RMOS3 real-time operating
system From page 5/146
G_ST80_XX_00457
265
99.1
3.6 295.2
99.8
11.2
78.5
3.9
272.8
ST80_2013_EN_Kap05.book Seite 46 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC827C
5/47
Siemens ST 80 / ST PC · 2013
Overview
SIMATIC IPC827C (Box PC):
The high-end IPC – with maximum performance,
functional scope and expansion capability
It offers:
Maximum performance and high expandability
with Intel Core i technology
Technical specifications
SIMATIC IPC827C
Supply voltage
Supply voltage 100 - 240 V AC, optional 24 V
Processor
Processor Core i7-610E (2C/4T, 2.53 GHz,
TB, HT, VT, AMT, 4MB cache);
Core i3-330E (2C/4T, 2.13 GHz, HT,
VT, 3MB cache); Celeron P4505
(2C/2T, 1.86 GHz, VT, 2MB cache);
Interfaces
PROFIBUS/MPI Onboard, isolated, max. 12 Mbit/s,
CP5611-compatible
USB port 4x USB 2.0 high speed/high current
Free slots 3xPCI, 1 x PCIe (x4), 1 x PCIe (x16),
1xslot for CompactFlash Card
Connection for keyboard/mouse USB / USB
serial interface COM1: 1 x V.24 (RS232)
Video interfaces
•Graphics interface DVI-I: VGA / DVI combined
Industrial Ethernet
• Industrial Ethernet interface 2 x Fast Ethernet
Monitoring functions
Temperature Yes
Watchdog Yes
Status LEDs Yes
Standards, approvals, certificates
Approval CE, cULus (508), C-Tick
EMC CE, EN 55022A, EN 61000-6-4,
EN 61000-6-2
Ambient conditions
Relative humidity
• Relative humidity Tested to DIN IEC 68-2-3,
DIN IEC 68-2-30,
DIN IEC 68-2-56: 5% to 80%
at 25 °C (no condensation)
Vibrations
• Vibration load in operation Tested to DIN IEC 68-2-6:
10 to 58 Hz: 0.075 mm,
58 to 200 Hz: 9.8 m/s
2
(1 g)
Shock testing
• Shock loading in operation Tested to DIN IEC 68-2-29:
50 m/s
2
(5g), 30 ms, 100 shocks
Operating systems
Operating system Windows XP Prof. SP3, MUI;
Windows 7 Ultimate 32/64Bit, MUI;
Windows Embedded Standard 2009
English on 8 GB CompactFlash;
without operating system;
Software
SIMATIC Software Optionally in package with
SIMATIC WinCC or WinCC flexible
Dimensions
Width 312 mm
Height 150 mm; with DVD drive: 170 mm
Depth 301 mm; incl. mounting rail
ST80_2013_EN_Kap05.book Seite 47 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC827C
5/48 Siemens ST 80 / ST PC · 2013
5
Ordering data
Order No. Order No.
Note:
Software Packages with SIMATIC WinCC flexible, WinCC RT
Advanced, SIMATIC WinCC, and SIMATIC WinAC RTX (F) can
be ordered together with the SIMATIC IPC at favorable prices.
More information under "Embedded Bundles / Packages for
industrial PCs".
SIMATIC IPC827C 6ES7647- 6 P
777
-
7777
Processor
Celeron P 4505
(2C/2T, 1.86 GHz, VT, 2 MB cache) A
Celeron P 4505
(2C/2T, 1.86 GHz, VT,
2 MB cache); PROFIBUS/MPI;
2 MB battery-backed SRAM
B
Celeron P 4505
(2C/2T, 1.86 GHz, VT,
2 MB cache);
PROFINET (3 x RJ45,
CP1616-compatible);
2 MB battery-backed SRAM
C
• Core i3-330E
(2C/4T, 2.13 GHz, HT, VT,
3 MB cache)
D
• Core i3-330E
(2.13 GHz, HT, VT,
3 MB cache); PROFIBUS/MPI;
2 MB battery-backed SRAM
E
• Core i3-330
(2C/4T, 2.13 GHz, HT, VT,
3 MB cache); PROFINET
(3 x RJ45, CP1616-compatible);
2 MB battery-backed SRAM
F
• Core i7-610E
(2C/4T, 2.53 GHz, TB, HT, VT,
AMT, 4 MB cache)
G
• Core i7-610E
(2C/4T, 2.53 GHz, TB, HT, VT,
AMT, 4 MB cache);
PROFIBUS/MPI;
2 MB battery-backed SRAM
H
• Core i7-610E
(2C/4T, 2.53 GHz, TB, HT, VT,
AMT, 4 MB cache);
PROFINET
(3 x RJ45, CP1616-compatible);
2 MB battery-backed SRAM
J
Memory configuration
1 GB DDR3 1066 DIMM 0
2 GB DDR3 1066 DIMM 1
3 GB DDR3 1066 DIMM 2
4 GB DDR3 1066 DIMM 3
8 GB DDR3 1066 DIMM 4
2 GB DDR3 1066 DIMM, ECC 5
4 GB DDR3 1066 DIMM, ECC 6
8 GB DDR3 1066 DIMM, ECC 7
Power supply
100/240 V AC industrial power
supply with Namur;
European cable
0
100/240 V AC industrial power
supply with Namur; UK cable 1
100/240 V AC industrial power
supply with Namur; Swiss cable 2
100/240 V AC industrial power
supply with Namur; USA cable 3
100/240 V AC industrial power
supply with Namur; Italian cable 4
100/240 V AC industrial power
supply with Namur; Chinese cable 5
24 V DC industrial power supply 6
SIMATIC IPC827C
(continued) 6ES7647- 6 P
7 7 7
-
7777
Expansions (HW)
• 3 x PCI, 2 x PCIe (x4),
1 x PCIe (x16) available 0
Mass storage
• 250 GB HDD SATA A
• 250 GB HDD SATA; DVD+/-RW B
• 500 GB HDD SATA C
• 500 GB HDD SATA; DVD+/-RW D
• 2 x 250 GB SATA (2.5") E
• 2 x 250 GB SATA (2.5") +
DVD+/-RW F
• RAID1 2 x 250 GB SATA (2.5") G
• RAID1 2 x 250 GB SATA (2.5");
DVD+/-RW H
• Solid-state drive 50 GB (SLC) J
• Solid-state drive 50 GB (SLC);
DVD+/-RW K
•DVD+/-RW W
• Without drives X
Operating system
(preinstalled and activated)
• Windows XP Professional MUI,
SP3 (Eng, Ger, Fr, It, Sp) A
• Windows 7 Ultimate, 32-bit, MUI
(Eng, Ger, Fr, It, Sp) B
• Windows 7 Ultimate, 64-bit, MUI
(Eng, Ger, Fr, It, Sp) C
Windows XP Embedded Standard
2009 English on
8 GB CompactFlash
F
• Without operating system X
Expansion software
• No expansion (software) 0
SIMATIC IPC DiagMonitor software
included 1
• SIMATIC IPC Image&Partition
Creator included 4
• SIMATIC IPC DiagMonitor &
Image & Partition Creator included 5
Note:
Windows Embedded only without
RAID option
ST80_2013_EN_Kap05.book Seite 48 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Box PC
SIMATIC IPC827C
5/49
Siemens ST 80 / ST PC · 2013
Ordering data Order No.
Dimensional drawings
All dimensions in mm. For mounting cut-out see technical speci-
fications.
More information
Weitere Informationen finden Sie im Internet unter:
http://www.siemens.com/simatic-pc
Accessories
Memory expansions
1 GB DDR3 1066, DIMM 6ES7648-2AJ40-0KA0
1 GB DDR3 1066, DIMM; ECC 6ES7648-2AJ40-1KA0
2 GB DDR3 1066, DIMM 6ES7648-2AJ50-0KA0
2 GB DDR3 1066, DIMM; ECC 6ES7648-2AJ50-1KA0
4 GB DDR3 1066, DIMM 6ES7648-2AJ60-0KA0
4 GB DDR3 1066, DIMM; ECC 6ES7648-2AJ60-1KA0
PCI expansion card
with COM1 and LPT 6ES7648-2CA01-0AA0
Graphics adapter cable
DVI-I acc. to VGA, 250 mm long 6ES7648-3AB00-0XA0
• DVI-I acc. to VGA and DVI-D,
250 mm long (Y cable) 6ES7648-3AE00-0XA0
Portrait assembly kit
Interfaces upward/downward 6ES7648-1AA30-0YA0
Interfaces to the front 6ES7648-1AA30-0YB0
Power supply cable
SIMATIC PC, power cable for
230 V AC, angled, 3 m for Box PC
and Panel PC for
Austria, Belgium, Finland, France,
Germany, Netherlands, Spain,
Sweden
6ES7900-1AA00-0XA0
United Kingdom 6ES7900-1BA00-0XA0
• Switzerland 6ES7900-1CA00-0XA0
•USA 6ES7900-1DA00-0XA0
•Italy 6ES7900-1EA00-0XA0
• China 6ES7900-1FA00-0XA0
Expansion components From page 5/153
Communication products From page 5/186
For power supplies and uninter-
ruptible power supplies From page 5/170
RMOS3 real-time operating
system From page 5/146
G_ST80_XX_00458
11
3
265
295.2
269.8 173.2
297.2
2.4
ST80_2013_EN_Kap05.book Seite 49 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC Panel PC
Panel PC
5/50 Siemens ST 80 / ST PC · 2013
5
Overview
SIMATIC Panel PCs are suitable thanks to their high industrial
compatibility for use in control cabinets, consoles and control
panels, as well as directly on the machine. Typical areas of appli-
cation can be found in both factory and process automation.
There is a broad range of robust, high-performance
SIMATIC Panel PCs available for different requirements.
Shared industrial functionality
High-quality components and modules with a high MTBF
(mean time between failure), which also ensure 24-hour
operation in the extended temperature range.
High swing/shock capacity of the devices through special
hard-disk suspensions, locked connectors and card retainers
Rugged housing model with high electromagnetic compati-
bility (EMC) and integrated industrial power supplies
(also as per NAMUR)
Service-friendly device design
Bright, brilliant displays in different sizes up to 19"
Same front panel mounting dimensions and uniform front
design across all device families
Rugged fronts protected from dust, humidity and chemical
substances (front-side IP65 / NEMA 4 degrees of protection)
SIMATIC IPC277:
The embedded Nanopanel PC – maintenance-free and
compact with displays starting from 7"
High degree of flexibility for selecting rugged widescreen
fronts from 7" to 19" for a more freely configurable display area
High resolution, large viewing angle, and up to 100%
dimmable backlighting for a brilliant display with optimized
power consumption
Absolutely maintenance-free due to the use of CompactFlash
or SSD as mass storage and fanless operation up to 50 °C
ambient temperature
Maximum industrial functionality due to non-volatile retentive
memory (option)
Ready-to-use embedded bundles with visualization and/or
control software
SIMATIC IPC477D:
The powerful embedded Panel PC – maintenance-free with
versatile configuration
Compact design
High performance with highly compact design and
ruggedness
Flexible expansion using a PCIe I/O card (optional)
No rotating parts (without fan and hard disk)
High security due to Windows Embedded Standard 7
operating system
Ready-to-use devices with optionally preinstalled software
- HMI: Innovative HMI software WinCC RT Advanced
(incl. archives and recipes)
- RTX: with real-time capable software PLC WinAC RTX
Retentive memory on board
(NV-RAM, usable with WinAC RTX)
SIMATIC HMI IPC477C:
The powerful embedded Panel PC – maintenance-free with
versatile configuration
Compact design
High performance with highly compact design and
ruggedness
Also available as PRO version (all-round IP65 degree of
protection) with 15" and 19" Touch displays
No rotating parts (without fan and hard disk)
High security due to Microsoft Windows Embedded Standard
2009 or Windows Embedded Standard 7 operating systems
Ready-to-use devices with optionally preinstalled software
- HMI: Innovative HMI software WinCC flexible
(incl. archives and recipes)
- RTX: with real-time capable software PLC WinAC RTX
Retentive memory on board
(NV-RAM, usable with WinAC RTX)
SIMATIC HMI IPC677:
The high-end Panel PC – with maximum performance,
functional scope and expansion capability
Rugged, expandable industrial PC with different front panels
Rugged design for industrial use
Complete PC openness
Optional PROFIBUS or PROFINET onboard
All CPUs with dual core
ST80_2013_EN_Kap05.book Seite 50 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC Panel PC
Panel PC
5/51
Siemens ST 80 / ST PC · 2013
Overview (continued)
SIMATIC IPC277D SIMATIC IPC477D SIMATIC HMI
IPC477C SIMATIC HMI
IPC577C SIMATIC HMI
IPC677C
7)
Design
Centralized configuration
Distributed configuration
(via remote kit) -----
Display
Size 7"/9"/12"/15"/19“
Widescreen TFT 12"/15"/19"/22"
Widescreen TFT 12"/15"/19" TFT 12"/15"/19" TFT 12"/15"/19" TFT
Resolution 800 x 480 /
800 x 480 /
1280 x 800 /
1280 x 800 /
1366 x 768
1280 x 800 /
1280 x 800 /
1366 x 768/
1920 x 1080
800 x 600/
1024 x 768/
1280 x 1024
800 x 600/
1024 x 768/
1280 x 1024
800 x 600/
1024 x 768/
1280 x 1024
Operator controls
Membrane keyboard -
8)
1)
1)
1)
Touch screen
General features
Power supply
24 V DC / 110/240 V AC •/- •/- •/- •/•/•
Processor Intel Atom E640,
1.0 GHz;
Intel Atom E660,
1.3 GHz
Intel Core i7-
3517UE, 1.7 GHz,
4 MB SLC
Intel Core i3-
3217UE, 1.6 GHz,
3 MB SLC
Intel Celeron 827E
1.4 GHz, 1.5 MB
SLC
Intel Celeron M
1.2 GHz
Intel Core2 Solo
1.2 GHz
Intel Core2 Duo
1.2 GHz
Intel Celeron M
1.2 GHz
Intel Core2 Solo
1.2 GHz
Intel Core2 Duo
1.86 GHz
Intel Celeron P4505,
1.86 GHz, 2 cores,
2 MB cache
Intel Core i3-330E,
2.13 GHz, 2 cores,
4 threads, 3 MB
cache, HT, VT-x
Intel Core i7-620E,
2.53 GHz, 2 cores,
4 threads, 4 MB
cache, TB, HT, VT-x,
VT-d
Main memory 1 GB, 2 GB 1 GB, 2 GB, 4 GB,
8 GB 1 GB, 2 GB, 4 GB 1 GB, 2 GB, 4 GB 1 GB, expandable up
to 8 GB, optional ECC
Expansion slots 1 x CF slot for
CompactFlash card
(externally accessi-
ble)
•1 x PCIe;
2 x CFast slot
(externally
accessible)
2 x CF slot for
CompactFlash Card
(internally and exter-
nally accessible)
•1 x PCI
2)
• 1 x CF slot for
CompactFlash card
(externally accessi-
ble)
2 x PCI or 1 x PCI
and 1 x PCIe x16
•1 x CF slot for
CompactFlash card
(externally
accessible)
Operating system • Windows
Embedded Stan-
dard 2009 or XP
Professional MUI
Windows
Embedded
Standard 7 (32-bit)
or Windows 7
Ultimate MUI
(32-bit)
• Without
Windows 7 Ultimate
MUI
(32-bit or 64-bit)
• Windows
Embedded
Standard 7 (32-bit)
• Windows Embed-
ded 2009 or XP
Professional MUI
Windows 7 Ultimate
MUI (32-bit) or
Windows
Embedded
Standard 7 (32-bit)
• Without
Windows
Embedded 2009
or XP Professional
MUI
• Without
• Windows XP
Professional MUI
Windows 7 Ultimate
32-bit MUI
Windows 7 Ultimate
64-bit MUI
• Windows Embed-
ded Standard 2009
on CF
Interfaces
PROFIBUS/MPI - • •
PROFINET (RT/IRT) • / - • / • • / • • / • • / •
Ethernet 2 x
10/100/1000 Mbps 2 x
10/100/1000 Mbps 2 x
10/100/1000 Mbps 2 x
10/100/1000 Mbps 2 x
10/100/1000 Mbps
USB
Serial interface
Graphics interface -
ST80_2013_EN_Kap05.book Seite 51 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC Panel PC
Panel PC
5/52 Siemens ST 80 / ST PC · 2013
Overview (continued)
5
• Available
- Not available
1)
12"/15" displays
2)
All slots with card retainer
3)
Valid with CF or SSD; with HDD: 5 g / 0.5 g;
4)
3 W taken into account for each PCI/PCIe slot
5)
15 W taken into account for each PCI/PCIe slot
6)
+0 °C to +50 °C; max. +50 °C in installation space;
max. 40 °C if at the front
7)
+0 °C to +45 °C for 19"
8)
15" display optionally as Touch/Key version
9)
With 12" and 15", vertical installation and use of CFast or SSD
More information
Additional information is available on the Internet at:
http://www.siemens.com/simatic-panel-pc
Note:
Do you need a specific modification or extension to the products
described here? Then refer to "Customized Automation". There
you will find information about additional and generally available
sector-specific products as well as options for customer-specific
modification and adaptation.
Examples are:
Specific front panels for SIMATIC Panel PC, e.g. honing
oil-resistant or with lateral function/movement keys
SIMATIC HMI Net Panel with 46" large-scale display
Ambient conditions
Vibration load during operation 1 g 1 g 1 g 1 g
3)
1 g
3)
Shock loading during operation 5 g 5 g 5 g 5 g
3)
5 g
Permissible temperature during
operation with maximum configuration +0 °C … +50 °C
7)
+0 °C … +50 °C
7)
+0 °C … +50 °C
7)
+0 °C … +45 °C
7)
+5 °C … +50 °C
6) 8)
Power loss in maximum
configuration
7" display 27 W
9" display 29 W
12" display 34 W 55 W 40 W
4)
55 W
5)
140 W
5)
15" display 42 W 56 W 45 W
4)
57 W
5)
140 W
5)
19" display 45 W 65 W 60 W
4)
84 W
5)
163 W
5)
22" display 74 W
SIMATIC IPC277D SIMATIC IPC477D SIMATIC HMI
IPC477C SIMATIC HMI
IPC577C SIMATIC HMI
IPC677C
7)
ST80_2013_EN_Kap05.book Seite 52 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC Panel PC
SIMATIC IPC277D
5/53
Siemens ST 80 / ST PC · 2013
Overview
SIMATIC IPC277D: The embedded Nanopanel PC – mainte-
nance-free and compact with displays starting from 7"
Offers great flexibility in the selection of rugged widescreen
fronts
From 7" to 19" for more freely configurable display area
High resolution, large viewing angle, and up to 100%
dimmable backlighting for a brilliant display with optimized
power consumption
Absolutely maintenance-free due to the use of CompactFlash
and SSD as mass storage and fanless operation up to 50 °C
ambient temperature
Maximum industrial functionality due to non-volatile retentive
memory
Ready-to-use embedded bundles with visualization or/and
control software
The following front installation versions are available:
•7" Touch
•9" Touch
12" Touch
15" Touch with USB interface on the front
19" Touch with USB interface on the front
All fronts as widescreen version
Technical specifications
SIMATIC IPC277D
General features
Processors • Intel Atom E660 1.3 GHz,
2 GB RAM
Intel Atom E640 1.0 GHz,
1 GB RAM
Chipset Intel Controller Hub EG20T
NVRAM optional 512 KB, of which 128 KB can be
written within the buffer time
Operating system Windows Embedded Standard
2009 preinstalled, in combination
with CF card of 2 GB or more,
or solid-state drive, or hard drive
(optional)
Windows XP Professional MUI
(in combination with solid-state
drive or hard drive; MUI:
Multi Language User Interface)
(optional)
• Windows Embedded Standard 7
32 bit,
preinstalled, in combination with
CF card
or solid-state drive (optional)
Windows 7 Ultimate MUI 32 bit
(in combination with solid-state
drive; MUI: Multi Language User
Interface) (optional)
• Linux
1)
(project-specific,
on request)
Others on request project-specifi-
cally
Power supply 24VDC (20.4V ... 28.8V)
•Isolated
With buffering of temporary power
failures: max. 10 ms
Line side switch
• With power failure indication
by means of Power Fail signal
Drives
FlashDrive Optional; replaceable, accessible,
diagnosable
•2GB
•4 GB
•8GB
•16 GB
Solid-state drive (SSD) Optional
50 GB SATA, High Endurance, 2.5"
80 GB SATA, Standard, 2.5"
CD/DVD/Floppy Via USB (not included in scope of
delivery)
Interfaces
PROFINET PROFINET RT via Standard Ethernet
controller
Ethernet 2 x 10/100/1000 Mbps (RJ 45)
Two independent Intel Controllers:
Intel 82574L / Intel Controller Hub
EG20T
With teaming function
USB V2.0, 3 x
Serial COM1 (V.24)
Keyboard Via USB (not included in scope of
delivery)
Mouse Via USB (not included in scope of
delivery)
1)
Suitable for specific LINUX versions in accordance with the specifications
of the Siemens manufacturer's declaration "Suitable for LINUX", see
http://www.siemens.com/simatic-pc/suited-for-linux
(LINUX is a trademark of Linus Torvald).
ST80_2013_EN_Kap05.book Seite 53 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC Panel PC
SIMATIC IPC277D
5/54 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
5
Monitoring functions
Temperature • Processor temperature
• Motherboard
Messages can be evaluated by the
application program
Watchdog Monitoring of program execution
Monitoring time can be parameter-
ized in software
Can be parameterized for a fault or
restart
Messages can be evaluated by the
application program
Monitoring functions via the network DiagBase
• SIMATIC IPC DiagMonitor
Remote monitoring capability for:
• Watchdog
•Temperature
Mass memory monitoring (SMART)
System/Ethernet monitoring
(Heart Beat)
Runtime meter
Communication:
Ethernet interface (SNMP protocol)
OPC for integration in
SIMATIC software
Configuration of client/server
architectures
Structure of log files
Supply voltage
Supply voltage 24 V DC
SIMATIC IPC277D
Monitoring functions
Temperature Yes
Watchdog Yes
Mass storage Yes
Ambient conditions
Vibration load during operation Requirements according to:
IEC 61131-2,
tested according to:
IEC 60068-2-6, Test Fc
10-58: 0.0375 mm,
58-200: 9.8 m/s
2
, 10x /axis
Shock loading during operation Requirements according to:
IEC 61131-2,
tested according to:
IEC 60068-2-27, test Ea,
50 m/s
2
Relative humidity Tested in accordance with
DIN IEC 68-78, DIN IEC 60068-2-30:
5% to 80% at 25 °C
(no condensation)
Maximum permissible installation
angle +/- 45° over vertical
Ambient temperature during operation 0 °C … +50° C in maximum configu-
ration; no fan (19": 0 °C … +45 °C)
Certifications & standards
Approvals CE, cULus (508),
marine approval available for
7" /9" /12", 15" /19" available soon:
GL, LRS, BV, DNV, ABS, ClassNK
EMC CE, FFC A, 55022A, EN 61000-6-4,
EN 61000-6-2
SIMATIC IPC277D
SIMATIC IPC277D
Front panel 7" TFT Touch,
widescreen 9" TFT Touch,
widescreen 12" TFT Touch,
widescreen 15" TFT Touch,
widescreen 19" TFT Touch,
widescreen
Display
Resolution (W x H in pixels) 800 x 480 800 x 480 1280 x 800 1280 x 800 1366 x 768
General features
Accessories Touch pen, touch
protective films Touch pen, touch
protective films Touch pen, touch
protective films Touch pen, touch
protective films Touch pen, touch
protective films
Type of operation
Function keys No No No No No
Alphanumeric keyboard No No No No No
Touch screen (analog/resistive) Yes Yes Yes Yes Yes
USB port on the front No No No Yes Yes
Design
Centralized configuration Yes Yes Yes Yes Yes
Distributed configuration No No No No No
Dimensions
Mounting dimensions in centralized
configuration (W x H x D) in mm 197 x 141 x 71 251 x 166 x 71 310 x 221 x 66 396 x 291 x 73 465 x 319 x 73
Operator control unit (W x H) in mm 214 x 158 274 x 190 330 x 241 415 x 310 483 x 337
Weight 1500 g 1950 g 2750 g 4000 g 5700 g
Max. power loss
in maximum configuration 27 W 29 W 37 W 42 W 45 W
ST80_2013_EN_Kap05.book Seite 54 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC Panel PC
SIMATIC IPC277D
5/55
Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
1)
10 units per packing unit
Please be sure to note:
The IPC277D with bundled software is always supplied with
inserted CF card.
The licenses are on the supplied USB flash drive.
Nanopanel PC SIMATIC IPC277D 6AV7881-
7
A
7
0 0 -
777
0
Interfaces: 2 x Gbit LAN (RJ45),
1 x serial (COM1), 3 x USB
Operating unit
Touch 7" TFT 1
Touch 9" TFT 2
Touch 12" TFT 3
Touch 15" TFT, front USB interface 4
Touch 19" TFT, front USB interface 5
Processors / memory configuration /
NVRAM
Atom E640 (1.0 GHz), 1 GB RAM A
Atom E640 (1.0 GHz), 1 GB RAM,
NVRAM B
Atom E660 (1.3 GHz), 2 GB RAM E
Atom E660 (1.3 GHz), 2 GB RAM,
NVRAM F
Drives
Without drive, with CF slot 0
2 GB SIMATIC PC CompactFlash 1
4 GB SIMATIC PC CompactFlash 2
8 GB SIMATIC PC CompactFlash 3
• 16 GB SIMATIC PC CompactFlash 4
50 GB Solid-State Drive SATA
(High Endurance) 7
80 GB Solid-State Drive SATA
(Standard) 8
Operating system
Without operating system A
WES 2009 preinstalled
(CF from 2 GB/SSD) B
XP-Prof. MUI preinstalled on SSD C
WES 7 32 bit preinstalled
(CF from 4 GB/SSD) D
Windows 7 MUI 32 bit preinstalled
on SSD E
Software bundles
Without RTX/HMI software A
• RTX: WinAC RTX 2010 B
RTX-F: WinAC RTX F 2010 C
HMI: WinCC RT Advanced 128 PT F
HMI: WinCC RT Advanced 512 PT G
HMI: WinCC RT Advanced
2048 PT H
HMI/RTX: RT 128 PT M
HMI/RTX: RT 512 PT N
HMI/RTX: RT 2048 PT P
HMI/RTX-F: RT 128 PT R
HMI/RTX-F: RT 512 PT S
• HMI/RTX-F: RT 2048 PT T
Accessories
Touch protective films 7"
1)
6AV2124-6GJ00-0AX0
Touch protective films 9"
1)
6AV2124-6JJ00-0AX0
Touch protective films 12"
1)
6AV2124-6MJ00-0AX0
Touch protective films 15"
1)
6AV2124-6QJ00-0AX0
Touch protective films 19"
1)
6AV2124-6UJ00-0AX0
Bracket clamp, long 6AV6671-8XK00-0AX4
for 15", 19" and 22" widescreen,
Comfort Panels, IPC, Flat Panel
monitors and Thin Client (except
SCD1900 19" widescreen)
Touch pen 6AV7672-1JB00-0AA0
Captive pen for operation of the
touch devices, mounting of the sup-
port on the control cabinet or directly
on the PRO unit
ST80_2013_EN_Kap05.book Seite 55 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC Panel PC
SIMATIC IPC277D
5/56 Siemens ST 80 / ST PC · 2013
5
Dimensional drawings
All dimensions in mm. For mounting cut-out see technical specifications.
SIMATIC IPC277D 7" version
SIMATIC IPC277D 9" version
SIMATIC IPC277D 12" version
SIMATIC IPC277D 15" version
129.5
4.8
8.5
6.2
71.1
77.3
2.3
36.5
177.6
G_ST80_XX_00466
214
158
196
140
129.5
4.8
32.5
71.1
77.3
2.3
36.5
35.7 177.6
6.2
G_ST80_XX_00467
190
274
249
164
141.5
4.8
75.5
72.6
66.42.3 6.2
G_ST80_XX_00468
219
241
330
38
276
308
6.2
25.5
10.5
99.5 141.5
G_ST80_XX_00518
73
415
289
310
394
2,3
ST80_2013_EN_Kap05.book Seite 56 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC Panel PC
SIMATIC IPC277D
5/57
Siemens ST 80 / ST PC · 2013
Dimensional drawings (continued)
SIMATIC IPC277D 19" version
6.2
25.5
10.5
141.5
G_ST80_XX_00519
463
483
2,3
73
113,5
317
337
More information
Further information can be found on the Internet at:
http://www.siemens.com/simatic-panel-pc
ST80_2013_EN_Kap05.book Seite 57 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC Panel PC
SIMATIC IPC477D
5/58 Siemens ST 80 / ST PC · 2013
5
Overview
SIMATIC IPC477D: The powerful embedded Panel PC –
maintenance-free with versatile configuration
Embedded PC platform with extremely high industrial compat-
ibility for demanding tasks in the field of PC-based automation
Maintenance-free (no rotating components such as fan and
hard disk)
Rugged construction: The PC is resistant to even the harshest
mechanical stress and is extremely reliable in operation
Compact design
Battery-independent retentive memory onboard
High degree of investment security
Fast integration capability
The following front versions are available:
Built-in versions
- 12" TFT Touch
- 15" TFT Touch
- 15" TFT Touch/Key
- 19" TFT Touch
- 22" TFT Touch
Technical specifications
SIMATIC IPC477D
General features
Supply voltage
1)
24 V DC (-20 % / +20 %)
1)
100 - 240 V AC (-15 % / +20 %);
50 - 60 Hz
Brief voltage interruption
in accordance with NAMUR • Min. 20 ms (DC)
Min. 20 ms (AC); max. 10 events
per hour; min. 1 s recovery time
Power consumption (DC) of devices
(without expansions):
• 12" display 55 W
• 15" display 56 W
• 19" display 65 W
• 22" display 74 W
Additional power consumption of
devices with expansions:
• DVD drive 1 W
• PCIe card 5 W
Processor • Intel Celeron 827E 1.4 GHz;
1.5 MB SLC or
Intel Core i3-3217UE 1.6 GHz;
3MB SLC or
Intel Core i7-3517UE 1.7 GHz;
4MB SLC
Main memory • SO-DIMM module;
1024 MB DDR3-SDRAM or
SO-DIMM module;
2048 MB DDR3-SDRAM or
SO-DIMM module;
4096 MB DDR3-SDRAM or
SO-DIMM module;
8192 MB DDR3-SDRAM
Buffer memory
2)
512 KB MRAM
Drive and storage media
SATA drive 1 slot
Solid-state drive •1x50 GB; 2.5" SATA-SSD,
high endurance or
•1x80 GB; 2.5" SATA-SSD,
standard or
•1x160 GB; 2.5" SATA-SSD,
standard
Hard disk drive (HDD) •1x250 GB, 2.5"-SATA-HD
CFast card •2GB or
•4GB or
•8GB or
•16GB
DVD drive, RW 1 slot for devices with expansion
1)
The generation of the supply voltage by the line-side power supply
must be realized as safety extra-low voltage with safe electrical isolation,
isolated according to IEC 60364 4 41, or as SELV according to
IEC/UL/EN/DIN-EN 60950-1.
2)
For devices with retentivity.
ST80_2013_EN_Kap05.book Seite 58 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC Panel PC
SIMATIC IPC477D
5/59
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
3)
For unambiguous labeling, the Ethernet ports are numbered on the
enclosure. The numbering by the operating system can differ.
4)
Teaming can be set and initiated in the configuration interface. In teaming
operation, jumbo frames, e.g. for the camera application, are not
supported
Graphics
Display, resolution • 12" screen diagonal with LED
backlighting, resolution
1280 × 800 pixels, WXGA
(Wide XGA)
15" screen diagonal with LED
backlighting, resolution
1280 × 800 pixels,
WXGA(Wide XGA)
19" screen diagonal with LED
backlighting, resolution
1366 x 768 pixels
22" screen diagonal with LED
backlighting, resolution
1920 x 1080 pixels
Touch controller Resistive Tyco Elotouch controller
ELO CTR-2216SU-AT-CHP-00, touch
screen, analog resistive, touch force
with test pen of 2 mm diameter: 5 N
Backlighting (MTBF) LED
Half brightness life time, typical Min. 50000 h at 50 °C,
50% brightness
Graphics controller Intel HD 2000 or
Intel HD 4000
Graphics memory 32 … 512 MB shared memory
Resolutions, frequency, colors DVI-I: 640 x 480 … 1920 x 1200,
60 Hz
DP display port:
1920 x 1200, 60 Hz
Interfaces
COM 1 and COM 2 RS 232, max. 115 kbps, 9-pin,
sub-D connector
DVI Connection of VDUs
with DVI connection
Display port (DPP) Connection of VDUs
with DPP connection
Keyboard Connection via USB port
Mouse Connection via USB port
USB Rear of device:
4 x USB 3.0, max. 2 high-current
at the same time
Front of device (only with IPC477D
with 15", 19" or 22" display):
1 x USB 2.0, high-current
PROFIBUS/MPI 9-pole, 2 rows, electrically isolated,
Sub-D socket, compatible with
CP 5622
• Transmission rate 9.6 Kbps … 12 Mbps
• Operating modes DP master: DP-V0,
DP-V1 with SOFTNET-DP
DP slave: DP-V0,
DP-V1 with SOFTNET-DP slave
PROFINET 3 x RJ45 interface, CP 1616
compatible onboard interface
based on ERTEC 400
10/100 Mbps, electrically isolated
SIMATIC IPC477D
Ethernet
3)
• 2 x RJ45 connection,
Intel 82579LM and Intel 82574L
10/100/1000 Mbps, electrically
isolated, teaming-capable
4)
or
•For PROFINET versions:
1 x Ethernet
Slot for PCIe expansion cards Only for device with expansions:
1 x PCIe-x4 expansion card can be
used, max. permissible power loss:
5 W
Degree of protection
Degree of protection IP 20 to IEC 60529 (enclosure)
• IP 65 (front)
Quality assurance In accordance with ISO 9001
Electromagnetic compatibility
Emitted interference S EN 61000-6-4; CISPR 22 Class A;
FCC Class A
Immunity with regard to conducted
interference on the supply lines • ± 2 kV to IEC 61000-4-4; burst
± 1 kV to IEC 61000-4-5;
surge symmetrical
± 2 kV to IEC 61000-4-5; surge
asymmetrical
Noise immunity on signal lines ± 2 kV to IEC 61000-4-4; burst,
length > 3 m
± 1 kV to IEC 61000-4-4; burst,
length < 3 m
± 2 kV to IEC 61000-4-5;
symmetrical surge, length > 30 m
Immunity to static discharge • ± 6 kV, contact discharge
at the front to IEC 61000-4-2
± 4 kV contact discharge
at the rear to IEC 61000-4-2
± 8 kV air discharge
to IEC 61000-4-2
Immunity to high radio frequency
interference • 10 V/m, 80 … 1000 MHz
80 % AM to IEC 61000-4-3
1 V/m, 2 … 2.7 GHz
3 V/m, 2 … 2.7 GHz
• 10 V, 10 kHz … 80 MHz to
IEC 61000-4-6
Immunity to magnetic fields 100 A/m, 50/60 Hz
to IEC 61000-4-8
Weight
• IPC477D, touch device,
12" display Approx. 3200 g
• IPC477D, touch device,
15" display Approx. 4920 g
• IPC477D, touch/key device
(without expansions),
15" display
Approx. 5750 g
• IPC477D, touch device,
19" display Approx. 6400 g
• IPC477D, touch device,
22" display Approx. 7000 g
SIMATIC IPC477D
ST80_2013_EN_Kap05.book Seite 59 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC Panel PC
SIMATIC IPC477D
5/60 Siemens ST 80 / ST PC · 2013
5
Ordering data
Order No. Order No.
SIMATIC IPC477D
1)
6AV7240-
777 7 7
-
7 7
A 0
Processor and fieldbus:
Celeron U827E
(1C/1T, 1.4 GHz, 1.5 MB cache);
2 x Gigabit Ethernet (IE/PN)
0
Celeron U827E
(1C/1T, 1.4 GHz, 1.5 MB cache);
2 x Gigabit Ethernet (IE/PN);
PROFIBUS DP12
1
• Core i3-3217UE
(2C/4T, 1.6 GHz, 3 MB cache);
2 x Gigabit Ethernet (IE/PN)
3
• Core i3-3217UE
(2C/4T, 1.6 GHz, 3 MB cache);
2 x Gigabit Ethernet (IE/PN);
PROFIBUS DP12
4
• Core i3-3217UE
(2C/4T, 1.6 GHz, 3 MB cache);
1 x Gigabit Ethernet (IE/PN);
1 x PROFINET (IRT, 3 ports)
5
• Core i7-3517UE
(2C/4T, 1.7 (2.8) GHz,
3 MB cache);
2 x Gigabit Ethernet (IE/PN)
6
• Core i7-3517UE
(2C/4T, 1.7 (2.8) GHz,
3 MB cache); 2 x Gigabit Ethernet
(IE/PN); PROFIBUS DP12
7
• Core i7-3517UE
(2C/4T, 1.7 (2.8) GHz,
3 MB cache); 1 x Gigabit Ethernet
(IE/PN); 1 x PROFINET
(IRT, 3 ports)
8
Operator control unit:
• 12" Touch (1280 x 800)
(caution, restrictions regarding
options: HDD, PCI, AC, DVD)
A
• 15" Touch (1280 x 800)
with front USB B
15" Touch/Key (1280 x 800)
with front USB C
• 19" Touch (1366 x 768)
with front USB D
• 22" Touch (1920 x 1080)
with front USB E
Main memory/NVRAM:
•1 GB A
•2 GB B
•4 GB C
•8 GB D
1 GB and NVRAM J
2 GB and NVRAM K
4 GB and NVRAM L
8 GB and NVRAM M
1)
Built to order versions with a delivery time of max. 15 working days and
with identified repair.
SIMATIC IPC477D
1)
(continued) 6AV7240-
7 7 777
-
7 7
A 0
Expansions/interface:
• 1 x RS 232, without PCIe 0
• 1 x RS 232 and 1 x PCIe 1
• Second RS 232, without PCIe 3
• Second RS 232 and 1 x PCIe 4
Operating system:
• Without operating system 0
• Windows Embedded Standard 7
SP1, English, 32-bit 4
• Windows 7 Ultimate SP1, 32-bit,
MUI (Eng, Ger, Fr, It, Sp) 6
• Windows 7 Ultimate SP1, 64-bit,
MUI (Eng, Ger, Fr, It, Sp) 7
Externally accessible mass storage
(without operating system):
• Without external mass storage 0
• CFAST 2 GB, without software 1
•CFAST 4 GB 2
•CFAST 8 GB 3
•CFAST 16 GB 4
•DVD 6
Internal mass storage:
• Without internal mass storage A
•CFAST 2 GB B
•CFAST 4 GB C
•CFAST 8 GB D
•CFAST 16 GB E
• SSD 50 GB High Endurance G
• SSD 80 GB Standard H
• HDD 250 GB K
•DVD L
• SSD 50 GB high endurance
with DVD M
• SSD 80 GB standard with DVD N
• SSD 160 GB standard with DVD P
• HDD min. 250 GB with DVD Q
ST80_2013_EN_Kap05.book Seite 60 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC Panel PC
SIMATIC IPC477D
5/61
Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
1)
Built to order versions with a delivery time of max. 15 working days and
with identified repair.
2)
Only with main memory and NVRAM.
Dimensional drawings
All dimensions in mm. For mounting cut-out see technical specifications.
SIMATIC IPC477D 12" Touch device SIMATIC IPC477D 15" Touch device
SIMATIC IPC477D
1)
(continued) 6AV7240-
7 7 7 7 7
-
7 7
A 0
SIMATIC software preinstalled
(bundles):
Without SIMATIC software A
WinAC RTX 2010
2)
B
• WinCC RT Advanced 128 PT C
• WinCC RT Advanced 512 PT D
• WinCC RT Advanced 2048 PT E
• WinCC RT Advanced 4096 PT F
• WinCC RT Advanced 128 PT,
WinAC RTX
2)
J
• WinCC RT Advanced 512 PT,
WinAC RTX
2)
K
• WinCC RT Advanced 2048 PT,
WinAC RTX
2)
L
• WinCC RT Advanced 4096 PT,
WinAC RTX
2)
M
WinAC RTX 2010 F
2)
N
• WinCC RT Advanced 128 PT,
WinAC RTX F
2)
P
• WinCC RT Advanced 512 PT,
WinAC RTX F
2)
Q
• WinCC RT Advanced 2048 PT,
WinAC RTX F
2)
R
• WinCC RT Advanced 4096 PT,
WinAC RTX F
2)
S
SIMATIC IPC477D
1)
(continued) 6AV7240-
7 7 7 7 7
-
7 7
A 0
Power supply:
• 24 V DC industrial power supply 0
• 110/230 V AC industrial power
supply with Namur; no power
cable
1
• 110/230 V AC industrial power
supply with Namur; European
power cable
2
• 110/230 V AC industrial power
supply with Namur; US power
cable
3
• 110/230 V AC industrial power
supply with Namur; Chinese power
cable
4
• 110/230 V AC industrial power
supply with Namur; Italian power
cable
5
• 110/230 V AC industrial power
supply with Namur; Swiss power
cable
6
• 110/230 V AC industrial power
supply with Namur; UK power
cable
7
• 24 V DC industrial power supply
and TPM (not for China and
Russia)
8
4.6
2.3
6.2
82.2 178.739.1
276.4 11
38
11
330
G_ST80_XX_00523
241
219
308
11.2
393.9
372.4
2.3
6.2
75.5
25.5
81.6
288.9
194.668.2
415
310
G_ST80_XX_00524
ST80_2013_EN_Kap05.book Seite 61 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC Panel PC
SIMATIC IPC477D
5/62 Siemens ST 80 / ST PC · 2013
Dimensional drawings (continued)
5
SIMATIC IPC477D 19" Touch device
SIMATIC IPC477D 22" Touch device
SIMATIC IPC477D 15" Touch/Key device
More information
Additional information is available in the Internet under:
http://www.siemens.com/simatic-panel-pc
426.9
372.4
45.7
2.3
6.2
75.5
25.5
81.6
316.9
194.682.2
G_ST80_XX_00525
483
337
372.484.2
2.3
6.2
75.5
25.5
81.6 194.6103.8
G_ST80_XX_00526
560
540
380
360
372.4
38.2
2.3
6.2
75.5
25.5
81.6
194.668.2
G_ST80_XX_00527
483
448
310
289
ST80_2013_EN_Kap05.book Seite 62 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC Panel PC
SIMATIC HMI IPC477C
5/63
Siemens ST 80 / ST PC · 2013
Overview
SIMATIC HMI IPC477C: The powerful embedded Panel PC –
maintenance-free with versatile configuration
Embedded PC platform with extremely high industrial compat-
ibility for demanding tasks in the field of PC-based automation
Maintenance-free (no rotating components such as fan and
hard disk)
Rugged construction: The PC is resistant to even the harshest
mechanical stress and is extremely reliable in operation
Compact design (only 61-69 mm installation depth for 12"-19")
Battery-backed retentive memory onboard
High degree of investment security
Fast integration capability
The following front versions are available:
Built-in versions
- 12" and 15" TFT Touch
- 12" and 15" TFT keypad
- 19" Touch
Support arm versions
- PRO 15" and PRO 19" Touch
- Fully enclosed device with degree of protection IP65 for
mounting on a support arm/stand
Technical specifications
6AV7 884-1....-...0 6AV7 884-2....-...0 6AV7 884-3....-...0
SIMATIC HMI IPC477C SIMATIC HMI IPC477C SIMATIC HMI IPC477C
Operator control and monitoring
Accessory components Slide-in keyboard labels Touch protective foil
(not for Inox front) Slide-in keyboard labels
Display
Screen diagonal 12 in 15 in 15 in
Resolution (pixels)
Resolution (WxH in pixel) 800 x 600 1024 x 768 1024 x 768
General features
• Front panel 12" TFT Key 15" TFT Touch 15" TFT Key
Backlighting
• MTBF backlighting (at 25 °C) about 50,000 hours 50000 h about 50,000 hours
Control elements
Function keys 36 No 36
Mouse, at front Yes No Yes
Keyboard fonts
Alphanumeric keyboard Yes No Yes
Touch operation
• Design as touch screen No Yes No
- Touch screen (analog/resistive) No Yes No
Installation type/mounting
central design Yes Yes Yes
Distributed design No No No
Power losses
Power loss in full configuration 24 V DC: Max. 60 W
(incl. USB interfaces) 140 W max.
(15 W included per slot) 24 V DC: Max. 60 W
(incl. USB interfaces)
Dimensions
Mounting cutout (W x H x D) 450 mm x 290 mm/75 mm device
depth 450x290 / 108 (incl. optical drive) 450 x 321 x 75
additional mounting depth
(optical drive) No drive planned. No drive planned. No drive planned.
Weight
Panel PC in central design, approx. 6.6 kg 7kg 7.2 kg
ST80_2013_EN_Kap05.book Seite 63 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC Panel PC
SIMATIC HMI IPC477C
5/64 Siemens ST 80 / ST PC · 2013
5
Ordering data
Order No. Order No.
1)
Preferred types with replacement devices in exchange
Note:
Ready-to-use SIMATIC IPC477C (PRO) as bundles can be found
under "Embedded bundles".
Software packages with SIMATIC WinCC flexible, SIMATIC
WinCC RT Advanced, SIMATIC WinCC, SIMATIC WinCC RT
Professional, and SIMATIC WinAC RTX (F) can be ordered
together with the SIMATIC IPC with a price advantage.
More information under "Embedded bundles / Packages for
industrial PCs".
SIMATIC HMI IPC477C and
IPC477C PRO
(built to order versions with a deli-
very time of max. 15 working days
and with original part repair, if not
preferred type).
SIMATIC HMI IPC477C 6AV7884-
7
A
777
-
7 7 7
0
Embedded and fan-free
5 x USB (500 mA),
of which 1 x on the front,
battery-backed retentive
memory onboard,
24 V DC power supply
with On/Off switch
Front Panels
12" TFT Touch
1)
0
12" TFT Key 1
15" TFT Touch
1)
2
15" TFT Key 3
19" TFT Touch
1)
5
SIMATIC HMI IPC477C PRO 6AV7883-
7
A
777
-
7 7 7
0
Embedded and fan-free with IP65
enclosure protected all-round;
5 x USB (500 mA),
of which 1 x on the front,
battery-backed retentive
memory onboard,
24 V DC power supply
with On/Off switch
15" TFT Touch (IP65 enclosure) 6
19" TFT Touch (IP65 enclosure) 7
Processors and fieldbus
• Celeron M 1.2 GHz,
2 x PROFINET (IE)
1)
A
• Celeron M 1.2 GHz,
2 x PROFINET (IE),
1 x PROFIBUS DP 12
1)
B
• Core2 Solo 1.2 GHz,
2 x PROFINET (IE)
1)
D
• Core2 Solo 1.2 GHz,
2 x PROFINET (IE),
1 x PROFIBUS
1)
E
• Core2 Solo 1.2 GHz,
1 x PROFINET (IE),
1 x PROFINET (RT/IRT) (3 ports)
F
Core2 Duo 1.2 GHz,
2 x PROFINET (IE)
1)
G
Core2 Duo 1.2 GHz,
2 x PROFINET (IE),
1 x PROFIBUS
1)
H
Core2 Duo 1.2 GHz,
1 x PROFINET (IE),
1 x PROFINET (RT/IRT) (3 ports)
J
SIMATIC HMI IPC477C PRO
(continued) 6AV7883-
7
A
777
-
777
0
Main memory (DDR3 RAM), 1 bank
•1 GB 1
•2 GB
1)
2
•4GB 3
Second mass storage
(installed and formatted)
• Without
1)
0
• CompactFlash 2 GB
1)
2
• CompactFlash 4 GB
1)
3
• CompactFlash 8 GB
1)
4
• CompactFlash 16 GB
1)
5
• SSD High Endurance, min. 50 GB 6
• SSD Standard, min. 80 GB
(not for PRO version) 7
Mass storage (built-in, operating
system pre-installed)
• CompactFlash 2 GB
(only with Windows Embedded
Standard 2009)
1)
2
• CompactFlash 4 GB
1)
3
• CompactFlash 8 GB
1)
4
• CompactFlash 16 GB
1)
5
• SSD High Endurance, min. 50 GB 6
• SSD Standard, min. 80 GB
(not for PRO version) 7
Operating system
(preinstalled and activated)
• Windows Embedded Standard
2009
1)
B A
• Windows XP Professional
Multi-Language, only with SSD;
without SIMATIC software
D A
• Windows Embedded Standard 7
(only with CF > 4 GB or SSD and
from 2 GB RAM)
E A
• Windows 7 Ultimate, MUI
(Eng, Ger, Fr, It, Sp) only with SSD;
without SIMATIC software
G A
SIMATIC HMI IPC477C (PRO)
with SIMATIC software See Embedded bundles / Packages
for industrial PCs
ST80_2013_EN_Kap05.book Seite 64 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC Panel PC
SIMATIC HMI IPC477C
5/65
Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
Please be sure to note:
The HMI IPC477C is delivered as standard with an inserted
CF card. The licenses are on the supplied USB flash drive.
Note:
Further embedded versions based on IPC427C and Embedded
Controller (mEC) are listed under SIMATIC PC-based Control.
Dimensional drawings
All dimensions in mm. For mounting cut-out see technical specifications.
SIMATIC HMI IPC477C 12" Key version SIMATIC HMI IPC477C 12" Touch version
Accessories
Protective film
for Panel PCs 477/577/677
For protecting the touch screen
against dirt/scratches
• for 12" Touch 6AV7671-2BA00-0AA0
• for 15" Touch (not for PRO) 6AV7671-4BA00-0AA0
• for 19" Touch 6AV7672-1CE00-0AA0
Labeling membranes
for Panel PCs 477/577/677 6AV7672-0DA00-0AA0
For labeling soft keys and function
keys, blank, supplied in sets of 10
Touch pen 6AV7672-1JB00-0AA0
Captive pen for operation of the
touch devices, mounting of the sup-
port on the control cabinet or directly
on the PRO unit
Expansion components From page 5/153
10.5
4.8
482.6
70.8
60.3
310.3
59.15 207.5
288.3
447.2
65.1
G_ST80_XX_00395
465
44
235
328
10.5
4.8
310.3
59.15 207.5
288.3 70.8
60.3
19.5
37.3
G_ST80_XX_00396
400
328
366
ST80_2013_EN_Kap05.book Seite 65 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC Panel PC
SIMATIC HMI IPC477C
5/66 Siemens ST 80 / ST PC · 2013
Dimensional drawings (continued)
5
SIMATIC HMI IPC477C 15" Key version SIMATIC HMI IPC477C 15" Touch version
SIMATIC HMI IPC477C 19" Touch version
More information
Additional information is available in the Internet under:
http://www.siemens.com/simatic-panel-pc
4.8
10.5
482.6
43.5
69.8
59.3
354.8
447.2
65.1
319.4
74.7 207.5
G_ST80_XX_00397
465
235
328
10.5
4.8
482.6
74.6
64.1
310.3
59.1 207.5
288.3
447.2
88.1
40.1
G_ST80_XX_00398
328
465
235
10.5
4.8
482.6
207.5
70.5
447.2
88.1
40.9
G_ST80_XX_00399
400
378
81
328
104
465
235
ST80_2013_EN_Kap05.book Seite 66 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC Panel PC
SIMATIC HMI IPC577C
5/67
Siemens ST 80 / ST PC · 2013
Overview
Rugged, expandable industry PC for demanding tasks in the
area of PC-based automation with various control units
(front panels):
Rugged and compact design for industrial use
Full PC openness
- Windows Embedded Standard or Windows XP Professional,
or without operating system
- CF card, HDD, SSD
- DVD drive
Expandable using a PCI slot
Optionally with PROFIBUS or PROFINET (RT/IRT) onboard
Installation-compatible with Panel PC 577B
- Touch screen control units with 12", 15" and 19" TFT display
- 12" and 15" TFT Key
High degree of investment protection
Technical specifications
6AV7 885-0....-.... 6AV7 885-1....-.... 6AV7 885-2....-.... 6AV7 885-3....-.... 6AV7 885-5....-....
SIMATIC HMI
IPC577C SIMATIC HMI
IPC577C SIMATIC HMI
IPC577C SIMATIC HMI
IPC577C SIMATIC HMI
IPC577C
Operator control and monitoring
Accessory components Touch protective foil Slide-in keyboard
labels Touch protective foil Slide-in keyboard
labels Touch protective foil
Display
Screen diagonal 12 in 12 in 15 in 15 in 19 in
Resolution (pixels)
Resolution (WxH in pixel) 800 x 600 800 x 600 1024 x 768 1024 x 768 1280 x 1024
General features
• Front panel 12" TFT touch display 12" TFT Key 15" TFT touch display 15" TFT Key 19" TFT Touch
Backlighting
• MTBF backlighting (at 25 °C) about 50,000 hours about 50,000 hours about 50,000 hours about 50,000 hours about 50,000 hours
Control elements
Function keys No 36 No 36 No
Mouse, at front No Yes No Yes No
Keyboard fonts
Alphanumeric keyboard No Yes No Yes No
Touch operation
• Design as touch screen Yes No Yes No Yes
- Touch screen (analog/resistive) Yes No Yes No Yes
Installation type/mounting
central design Yes Yes Yes Yes Yes
Distributed design No No No No No
Power losses
Power loss in full configuration 24 V DC: Max. 80 W
(incl. USB interfaces) 24 V DC: Max. 80 W
(incl. USB interfaces) 24 V DC: Max. 80 W
(incl. USB interfaces) 24 V DC: Max. 80 W
(incl. USB interfaces) 24 V DC: Max. 80 W
(incl. USB interfaces)
Dimensions
Mounting cutout (W x H x D) 368 x 290 x 115 450 x 290 x 115 450 x 290 x 120 450 x 321 x 115 450 x 380 x 125
additional mounting depth
(optical drive) 23 mm 23 mm 23 mm 23 mm 23 mm
Weight
Panel PC in central design, approx. 8.1 kg 8.6 kg 9kg 9.3 kg 11.6 kg
ST80_2013_EN_Kap05.book Seite 67 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC Panel PC
SIMATIC HMI IPC577C
5/68 Siemens ST 80 / ST PC · 2013
5
Ordering data
Order No. Order No.
Note:
Software Packages with SIMATIC WinCC flexible, SIMATIC
WinCC and SIMATIC WinAC RTX (F) can be ordered together
with the SIMATIC IPC with a price advantage.
More information under "Embedded Bundles / Packages for
industrial PCs".
SIMATIC HMI IPC577C 6AV7885-
77777
-
7 7 7 7
Front Panels
12" TFT Touch 0
12" TFT Key 1
15" TFT Touch 2
15" TFT Key 3
19" TFT Touch 5
Mainboards
(processor with fieldbus interfaces)
• Celeron M 1.2 GHz, 1 MB cache,
800 MHz FSB
- with PROFINET
(Industrial Ethernet);
2x LAN 1 Gbps
A A
• Core2 Solo 1.2 GHz, 3 MB cache,
800 MHz FSB
- with PROFINET
(Industrial Ethernet),
2x LAN 1 Gbps
A D
- with PROFIBUS DP12/MPI
(CP5611-compatible),
2x LAN 1 Gbps
A E
- with PROFINET (RT/IRT) 3 ports,
1x LAN 1 Gbps A F
Core2 Duo 1.86 GHz, 6 MB cache,
1066 MHz FSB
- with PROFINET
(Industrial Ethernet),
2x LAN 1 Gbps
A K
- with PROFIBUS DP12/MPI
(CP5611-compatible),
2x LAN 1 Gbps
A L
- with PROFINET (RT/IRT) 3 ports,
1x LAN 1 Gbps A M
RAM
1 GB RAM, DDR3 1
2 GB RAM, DDR3 2
4 GB RAM, DDR3 3
Second mass storage and/or
drive (formatted without operating
system)
No second mass storage/drive 0
• DVD-RW drive 1
• HDD + DVD-RW drive 2
• SSD 50 GB High Endurance+
DVD-RW drive 3
• SSD 80 GB Standard+
DVD-RW drive 4
• SSD 50 GB High Endurance 6
• SSD 80 GB Standard 7
• HDD min. 250 GB 8
1) Multi-Language means: D/E/F/I/SP/CHIN traditional/CHIN simplified/
Korean/Japanese
SIMATIC HMI IPC577C
(continued) 6AV7885-
7 7 7 7 7
-
7777
First mass storage (formatted,
optionally with operating system):
• Without 0
• HDD min. 250 GB (not if
2nd mass storage HDD or SSD) 1
• 2 GB CompactFlash 2
• 4 GB CompactFlash 3
• 8 GB CompactFlash 4
• 16 GB CompactFlash 5
SSD 50 GB High Endurance (not if
2nd mass storage HDD or SSD) 6
• SSD 80 GB Standard (not if 2nd
mass storage HDD or SSD) 7
Operating system
(pre-installed on first mass storage)
• Without operating system A
• Windows Embedded Standard B
• Windows XP Professional
Multi-Language
1)
D
• Windows Embedded Standard 7 E
• Windows 7 Ultimate
Multi-Language
1)
G
Expansion (software)
• Without expansion A
• IPC DiagMonitor V4.3 enclosed B
• IPC Image & Partition Creator C
IPC DiagMonitor V4.3 and Image &
Partition Creator V3.2 enclosed D
Power supply
• 100/240 V AC industrial power
supply with Namur 1
• 100/240 V AC industrial power
supply with Namur; power cable
for Europe
2
• 100/240 V AC industrial power
supply with Namur; power cable
for the USA
3
• 100/240 V AC industrial power
supply with Namur; CN power
cable
4
• 100/240 V AC industrial power
supply with Namur; IT power cable 5
• 100/240 V AC industrial power
supply with Namur; CH cable 6
• 100/240 V AC industrial power
supply with Namur; UK cable 7
• 24 V DC industrial power supply 8
ST80_2013_EN_Kap05.book Seite 68 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC Panel PC
SIMATIC HMI IPC577C
5/69
Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
Dimensional drawings
All dimensions in mm. For mounting cut-out see technical specifications.
SIMATIC HMI IPC577C 12" Key version SIMATIC HMI IPC577C 12" Touch version
Accessories
Protective film
for SIMATIC HMI IPC577C
For protecting the touch screen
against dirt/scratches,
set of 10
• for 12" Touch 6AV7671-2BA00-0AA0
• for 15" Touch 6AV7671-4BA00-0AA0
• for 19" Touch 6AV7672-1CE00-0AA0
Labeling strips for Key devices 6AV7672-0DA00-0AA0
For labeling soft keys and function
keys, blank, supplied in sets of 10
Touch pen 6AV7672-1JB00-0AA0
Captive pen for operation of the
touch devices, mounting of the
support on the control cabinet
Expansion components From page 5/153
Communication components From page 5/186
10.5
482.6
70.8
104.4
310.3
48.7
288.3
G_ST80_XX_00402
229
465
235
10.5
55.6
288.3 83.8
104.4
354.4
310.3
G_ST80_XX_00403
229
400
ST80_2013_EN_Kap05.book Seite 69 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC Panel PC
SIMATIC HMI IPC577C
5/70 Siemens ST 80 / ST PC · 2013
Dimensional drawings (continued)
5
SIMATIC HMI IPC577C 15" Key version
SIMATIC HMI IPC577C 15" Touch version
SIMATIC HMI IPC577C 19" Touch version
More information
Additional information is available in the Internet under:
http://www.siemens.com/simatic-panel-pc
10.5
103.4
82.8
71.2
319.4
482.6
354.8
G_ST80_XX_00404
229
465
235
10.5
87.6
482.6
108.2
310.3
55.6
288.3
G_ST80_XX_00405
229
328
465
235
10.5
114.6
102.4
354.4
G_ST80_XX_00406
94
229
378
400
483
465
235
ST80_2013_EN_Kap05.book Seite 70 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC Panel PC
SIMATIC HMI IPC677C
5/71
Siemens ST 80 / ST PC · 2013
Overview
SIMATIC HMI IPC677C: The high-end Panel PC –
with maximum performance, functional scope and
expansion capability
Compact design
High degree of investment security
Fast integration capability
Front panel versions:
- 12", 15" and 19" TFT Touch
- 12" and 15" TFT Key
- 15" TFT Touch INOX with stainless steel front for special
requirements, e.g. in the food, beverages and tobacco
industries
Technical specifications
SIMATIC HMI IPC677C
General features
Processor • Intel Core i7-610E
(2C/4T, 2.53 GHz, 4 MB L2,
Turbo Boost, VT-d)
Intel Core i3-330E
(2C/4T, 2.13 GHz, 3 MB L2)
Intel Celeron P4505
(2C/2T, 1.86 GHz, 2 MB L2)
Main memory 1 GB, optionally 2, 3, 4 or 8 GB or
2, 4 or 8 GB with ECC
Free slots for expansions 2 x PCI (slot with card retainer) or
1 x PCI and 1 x PCIe x16
1 x slot for CompactFlash Card
(accessible from outside)
Operating system Different Windows operating
systems incl. Windows 7 Ultimate
64-bit
Power supply 24 V DC or 110/240 V AC
(autorange), 50/60 Hz
MTBF backlighting Typ. 50 000 h (at 24 h continuous
operation, temperature-dependent)
Drives
Optical drives Optional DVD±RW±R combo drive,
at the rear, operable from the side
Hard disk/mass storage 3.5" SATA hard disk 250 GB;
optional 3.5" SATA hard disk
500 GB,
Dual hard disk module
2 x 250 GB SATA as single
disk configuration or RAID1
preconfigured,
50 GB SSD (solid-state drive)
ST80_2013_EN_Kap05.book Seite 71 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC Panel PC
SIMATIC HMI IPC677C
5/72 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
5
1)
61000-6-2 replaces 50082-2; 61000-6-4 replaces 50081-2
2)
Valid with CF or SSD; with HDD: 5 g/0.5 g
Interfaces
Graphics interface DVI-I for additional display unit:
Color depth 32 bits
Connection for keyboard/mouse USB / USB
Serial interface COM1: 1 x V.24 (RS232)
PROFIBUS DP/MPI Onboard, isolated, max. 12 Mbit/s,
compatible with CP 5611,
not upgradeable
PROFINET (IRT) Onboard, 3 x RJ 45,
CP 1616-compatible,
not upgradeable
PROFINET (IE), Ethernet Onboard, 2 x 10/100/1000 Mbit
USB 1 x on front, 4 x on rear,
USB 2.0 (500 mA)
Audio Possible via USB (external)
Multimedia No
Monitoring functions
Temperature Yes
Watchdog Yes
Ambient conditions
Degree of protection IP65 (front) in accordance
with EN 60529 and NEMA 4
Vibration load during operation Tested according to
DIN IEC 60068-2-6: 10 - 58 Hz:
0.075 mm, 58 to 500 Hz:
10 m/s² (1 g)
2)
Shock loading during operation Tested according to
DIN IEC 60068-2-27: 50 m/s²
(5 g), 30 ms, 100 shocks
EMC CE, FCC A, 55022A,
EN 61000-6-4
1)
, EN 61000-6-2
Ambient temperature
during operation 12"/15": 5 °C … +50 °C
in maximum configuration
19": 5 °C … +45 °C
in maximum configuration
Relative humidity Tested according to
DIN IEC 60068-78,
DIN IEC 60068-2-30: 5% to 80%
at 25 °C (no condensation)
Maximum permissible installation
angle +/- 20° over vertical
SIMATIC HMI IPC677C
Certifications & standards
Approvals CE, cULus(508)
ATEX 22, UL Class 1 Div 2
(see front options)
Shipbuilding approval
(for configurations with CompactFlash
or SSD memory and without optical
drive)
• GL - Germanische Lloyd
BV - Bureau Veritas
• LR - Lloyds Register of Shipping
ABS - American Bureau of
Shipping
• DNV - Det Norske Veritas
• NKK - Nippon Kaiji Kyokai
Expansion components Uninterruptible power supply (UPS),
SIMATIC NET communication
modules,
SIMATIC IPC DiagMonitor,
SIMATIC IPC Image & Partition
Creator,
SIMATIC IPC USB FlashDrive
SIMATIC HMI IPC677C
ST80_2013_EN_Kap05.book Seite 72 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC Panel PC
SIMATIC HMI IPC677C
5/73
Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
1)
Multi-Language means: D/E/F/I/SP/CHIN
2)
Only without RAID 1 option
Note:
Software Packages with SIMATIC WinCC flexible,
SIMATIC WinCC and SIMATIC WinAC RTX (F) can be ordered
together with the SIMATIC IPC with a price advantage.
More information under "Embedded Bundles / Packages for
industrial PCs".
SIMATIC HMI IPC677C 6AV789
7
-
7777 7
-
7 7 7 7
Front panels
12" TFT Touch 0
12" TFT Key 1
15" TFT Touch 2
15" TFT Key 3
19" TFT Touch 4
Front options
With front USB interface 0
Without front USB interface 1
• INOX front, without front USB,
with 15" TFT Touch only 3 2
19" TFT Touch with ATEX 22 and
UL Class 1 Division 2 certification 4 3
Power supply
24 V DC A
110/230 V AC,
power cable for Europe B
110/230 V AC, without power cable C
110/230 V AC, power cable for UK D
110/230 V AC, power cable for CH E
110/230 V AC,
power cable for the USA F
110/230 V AC,
power cable for Italy G
110/230 V AC,
power cable for China H
Processor
Intel Celeron 1.86 GHz
(2 Mbyte shared cache), 2 cores A
Intel Celeron 1.86 GHz
(2 MB shared cache),
2 cores, PROFIBUS MPI,
2 MB buffered SRAM
B
Intel Celeron 1.86 GHz
(2 MB shared cache),
2 cores, PROFINET
(3 x RJ45, CP1616-compatible),
2 MB buffered SRAM
C
• Intel Core i3; 2.13 GHz
(3 MB shared cache),
2 cores, hyper-threading
D
• Intel Core i3; 2.13 GHz
(3 MB shared cache), 2 cores,
hyper-threading, PROFIBUS MPI,
2 MB buffered SRAM
E
• Intel Core i3; 2.13 GHz
(3 MB shared cache), 2 cores,
hyper-threading, PROFINET
(3 x RJ45, CP1616-compatible),
2 MB buffered SRAM
F
• Intel Core i7; 2.53 GHz
(4 MB shared cache), 2 cores,
hyper-threading, turbo boost
G
• Intel Core i7; 2.53 GHz
(4 MB shared cache), 2 cores,
hyper-threading, turbo boost,
PROFIBUS MPI,
2 MB buffered SRAM
H
• Intel Core i7; 2.53 GHz
(4 MB shared cache), 2 cores,
hyper-threading, turbo boost,
PROFINET (3 x RJ45,
CP 1616-compatible),
2 MB buffered SRAM
J
SIMATIC HMI IPC677C
(continued) 6AV789
7
-
7 7 777
-
7777
Main memory
• 1 GB DDR3 0
• 2 GB DDR3 1
• 3 GB DDR3 2
• 4 GB DDR3 3
• 8 GB DDR3 4
• 2 GB DDR3 with ECC 5
• 4 GB DDR3 with ECC 6
• 8 GB DDR3 with ECC 7
Mass storage
• 250 GB SATA hard disk 0
• 500 GB SATA hard disk 1
• RAID1 dual hard disk module
2 x 250 GB SATA, preconfigured 2
• Dual hard disk module
2 x 250 GB SATA 3
• 50 GB SSD 4
• Second CF card slot, internal,
empty (not with Windows XP or
Windows 7) instead of hard disk
or SSD
5
• Without mass memory 8
Optical drives
• without 0
• DVD±RW±R combo drive 1
Communication interfaces
• 2x PCI free A
• 1x PCI, 1x PCIe (x16) free B
Operating system
(preinstalled and activated)
• Without operating system A
• Windows XP Professional
Multi-Language
1)
B
• Windows 7 Ultimate 32 Bit
Multi-Language
1)
C
• Windows Embedded Standard
on 8 GB CF card
2)
D
• Windows 7 Ultimate 64 Bit
Multi-Language
1)
E
Software expansion
• Without 0
• SIMATIC IPC DiagMonitor V4.3
enclosed 1
• SIMATIC IPC Image & Partition
Creator V3.2 enclosed 2
• SIMATIC IPC DiagMonitor V4.3,
Image & Partition Creator V3.2
enclosed
3
ST80_2013_EN_Kap05.book Seite 73 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC Panel PC
SIMATIC HMI IPC677C
5/74 Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
5
Preferred versions
12" TFT Touch 6AV7890-0BE00-1AB0
with Windows XP Prof. MUI,
110/230 V AC power supply,
Core i3 2.13 GHz, 2 x PCI,
1 GB RAM, 250 GB HDD
DVD±R/RW burner, PROFIBUS/MPI,
NVRAM
12" TFT Key 6AV7891-0BE00-1AB0
with Windows XP Prof. MUI,
110/230 V AC power supply,
Core i3 2.13 GHz, 2 x PCI,
1 GB RAM, 250 GB HDD
DVD±R/RW burner, PROFIBUS/MPI,
NVRAM
15" TFT Touch 6AV7892-0BE00-1AB0
with Windows XP Prof. MUI,
110/230 V AC power supply,
Core i3 2.13 GHz, 2 x PCI,
1 GB RAM, 250 GB HDD
DVD±R/RW burner, PROFIBUS/MPI,
NVRAM
15" TFT Key 6AV7893-0BE00-1AB0
with Windows XP Prof. MUI,
110/230 V AC power supply,
Core i3 2.13 GHz, 2 x PCI,
1 GB RAM, 250 GB HDD
DVD±R/RW burner, PROFIBUS/MPI,
NVRAM
19" TFT Touch 6AV7894-0BE00-1AB0
with Windows XP Prof. MUI,
110/230 V AC power supply,
Core i3 2.13 GHz, 2 x PCI,
1 GB RAM, 250 GB HDD
DVD±R/RW burner, PROFIBUS/MPI,
NVRAM
Accessories
Protective film for
Panel PCs 477/577/677/Flat Panel
Set of 10, for protecting the touch
screen against dirt/scratches
• for 12" Touch 6AV7671-2BA00-0AA0
• for 15" Touch 6AV7671-4BA00-0AA0
• for 19" Touch 6AV7672-1CE00-0AA0
Labeling strips for
Panel PC 477/577/677 key devices
For labeling soft keys and function
keys, blank, supplied in sets of 10 6AV7672-0DA00-0AA0
Memory expansion
• 1 GB DDR3 1066 SDRAM, DIMM 6ES7648-2AJ40-0KA0
• 2 GB DDR3 1066 SDRAM, DIMM 6ES7648-2AJ50-0KA0
• 4 GB DDR3 1066 SDRAM, DIMM 6ES7648-2AJ60-0KA0
• 1 GB DDR3 1066 SDRAM, DIMM,
ECC 6ES7648-2AJ40-1KA0
• 2 GB DDR3 1066 SDRAM, DIMM,
ECC 6ES7648-2AJ50-1KA0
• 4 GB DDR3 1066 SDRAM, DIMM,
ECC 6ES7648-2AJ60-1KA0
Non-heating apparatus cable for
SIMATIC Box and Panel PC
SIMATIC PC power cable,
230 V AC, angled, 3 m,
for:
• Germany 6ES7900-1AA00-0XA0
• United Kingdom 6ES7900-1BA00-0XA0
• Switzerland 6ES7900-1CA00-0XA0
•USA 6ES7900-1DA00-0XA0
•Italy 6ES7900-1EA00-0XA0
• China 6ES7900-1FA00-0XA0
Touch pen 6AV7672-1JB00-0AA0
Captive pen for operation of the
touch devices, mounting of the
support on the control cabinet
Expansion components From page 5/153
Communication components From page 5/186
ST80_2013_EN_Kap05.book Seite 74 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC Panel PC
SIMATIC HMI IPC677C
5/75
Siemens ST 80 / ST PC · 2013
Dimensional drawings
All dimensions in mm. For mounting cut-out see technical specifications.
Operator control unit and overall device
Note:
All dimensions without screw clearances.
Installation cutout
1)
In addition: Two cutouts 25 x 5 mm on the top for keyboard slide-in label
channels.
More information
Additional information is available in the Internet under:
http://www.siemens.com/simatic-panel-pc
Note
Do you need a specific modification or option for the products
described here? Under "Customized products", you will find
information about additional sector-specific products that can
be ordered as well as about options for customer-specific
modification and adaptation.
K
K
L
M
N
G_ST80_XX_00288
G
H
J
Operating units
IPC 677 G H J K L M N
Touch devices
12" 289 271 141 11 53 369 71
• 15" 289 271 138 11 24 367 42
19" 378 271 147 11 18 376 36
Key devices
• 12" 289 271 122 11 42 351 59
• 15" 324 271 141 11 31 370 48
W
W+1 (cutout)
H+1 (cutout)
H
G_ST80_XX_00289
Front dimensions Installation cutout
W H W+1 H+1 D
Touch devices
• 12" 400 310 368 290 51
• 15" 483 310 450 290 55
• 19" 483 400 450 380 57
Key devices
• 12" 483 310 450 290
• 15" 483 355 450 321
1)
ST80_2013_EN_Kap05.book Seite 75 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC PC-based controllers
SIMATIC PC-based controllers
5/76 Siemens ST 80 / ST PC · 2013
5
Overview
Siemens has developed a wide range of coordinated hardware
and software components for PC-based Automation.
Focal point: SIMATIC PC-based Control with SIMATIC WinAC,
the open, flexible and reliable controller for your PC-based
automation solution.
All automation tasks can be implemented on one platform on the
PC, such as open-loop control, closed-loop control, HMI and
motion control. PC-based Automation is your first choice
wherever PC applications have to be handled in addition to
classic PLC tasks.
SIMATIC PC-based Control
Adds PC-based controllers to the SIMATIC S7 controller family
Especially suitable where a variety of tasks such as data
processing, communication, visualization, technology and
control have to be integrated in one PC.
Versions
SIMATIC WinAC Software PLC
for tasks requiring a high level of flexibility and integration
capability.
SIMATIC WinAC ODK
allows PC solutions for technological tasks to be integrated
flexibly and powerfully into the controller.
Properties:
Runs on standard PCs under Windows XP Professional SP2.
Code-compatible with SIMATIC S7:
Programmed with SIMATIC industrial software, created
programs can also be used for SIMATIC S7.
Uses standard interfaces for integration into the office
environment.
Open interfaces for the integration of solution-specific techno-
logical hardware and software.
More information
Brochures
Information material for downloading can be found in the
Internet:
http://www.siemens.com/simatic/printmaterial
ST80_2013_EN_Kap05.book Seite 76 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC PC-based controllers
SIMATIC WinAC RTX
5/77
Siemens ST 80 / ST PC · 2013
Overview
SIMATIC WinAC RTX:
Optimized for applications that require a high degree of
flexibility and integration capability.
The software solution for tasks that require hard deterministic
behavior and high performance.
With real-time expansion for assuring deterministic behavior
for the control section.
New with WinAC RTX 2010:
Operation under Windows 7
Web server
New PROFINET functions:
- Isochronous mode
- Shared Device
- Media redundancy
- IP configuration
Technical specifications
6ES7671-0RC08-0YA0
SIMATIC WinAC RTX 2010
General information
Hardware product version -
Firmware version V4.6
Engineering with
Programming package STEP7 as of V5.5 +
HW update / iMap V3.0 SP1
Memory
Work memory
integrated (for program) 4 Mbyte; Adjustable; depends on
Non Paged Memory Pool
integrated (for data) 4 Mbyte; Adjustable; depends on
Non Paged Memory Pool
Load memory
integrated RAM, max. 8 Mbyte; Adjustable; depends on
Non Paged Memory Pool
CPU processing times
for bit operations, typ. 0.004 µs; typ.
for fixed point arithmetic, typ. 0.003 µs; typ.
for floating point arithmetic, typ. 0.004 µs; typ.
Reference platform Pentium IV, 2.4 GHz
CPU-blocks
DB
•Number, max. 65 535; Limited only
by RAM set for data
•Size, max. 64 kbyte
FB
•Number, max. 65 536; Limited only
by RAM set for code
•Size, max. 64 kbyte
FC
•Number, max. 65 536; Limited only
by RAM set for code
•Size, max. 64 kbyte
OB
•Size, max. 64 kbyte
Nesting depth
per priority class 24
• additional within an error OB 24
Counters, timers and
their retentivity
S7 counter
•Number 2 048
• Retentivity
-adjustable Yes
- lower limit 0
-upper limit 2 047
-preset 8
• Counting range
-adjustable Yes
- lower limit 0
-upper limit 999
IEC counter
• present Yes
• Type SFB
•Number Unlimited
(limited only by RAM capacity)
S7 times
•Number 2 048
• Retentivity
-adjustable Yes
- lower limit 0
-upper limit 2 047
-preset 0
•Time range
- lower limit 10 ms
-upper limit 9 990 s
IEC timer
• present Yes
• Type SFB
•Number Unlimited
(limited only by RAM capacity)
Data areas and their retentivity
Retentivity without
UPS and PS Extension Board 128 kbyte with SIMATIC IPC427C
and HMI IPC477C; further
SIMATIC PCs on request
Retentivity with UPS all data
Flag
•Number, max. 16 kbyte
• Retentivity preset MB 0 to MB 15
• Number of clock memories 8
Data blocks
• Retentivity adjustable Yes; via non-retain property on DB
• Retentivity preset Yes
6ES7671-0RC08-0YA0
SIMATIC WinAC RTX 2010
ST80_2013_EN_Kap05.book Seite 77 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC PC-based controllers
SIMATIC WinAC RTX
5/78 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
5
Local data
• adjustable, max. 64 kbyte
•preset 32 kbyte
per priority class, max. 61 440 byte
Address area
I/O address area
• Inputs 16 kbyte
•Outputs 16 kbyte
• of which, distributed
- DP interface, inputs 16 kbyte
- DP interface, outputs 16 kbyte
- PN interface, inputs 16 kbyte
- PN interface, outputs 16 kbyte
Process image
• Inputs, adjustable 8kbyte
Outputs, adjustable 8kbyte
• Inputs, default 512 byte
Outputs, default 512 byte
Subprocess images
Number of subprocess images, max. 15
Digital channels
• Inputs 128 000
•Outputs 128 000
Analog channels
• Inputs 8 000
•Outputs 8 000
Hardware configuration
Submodules
Number of submodules, max 4
• of which PROFIBUS, max. 4; Supported interfaces:
see 1st and 2nd interface
• of which Industrial Ethernet, max. 1; Supported interfaces:
see 3rd and 4th interface
Number of operable FMs and CPs
(recommended)
•FM FM distributed: FM 350-1 / 350-2,
FM 351, FM 352, FM 353, FM 355 /
355-2
CP, point-to-point 2; CP 340, CP 341 distributed
•CP, LAN Over PC CP
Time of day
Clock
Hardware clock (real-time clock) Yes
• battery-backed and synchronizable Yes
Operating hours counter
•Number 8
Clock synchronization
• supported Yes
•to PC-CP, slave Yes
on Ethernet via NTP Yes
Interfaces
Number of USB interfaces 0
1st interface
Type of interface CP 5611-A2, CP 5621, integrated
PB interface of the SIMATIC PC
Max. no. of simultaneously operable
CPs 1
Physics RS 485 / PROFIBUS
Isolated Yes
Power supply to interface
(15 to 30 V DC), max. does not exist
Number of connection resources 8
6ES7671-0RC08-0YA0
SIMATIC WinAC RTX 2010
Functionality
•MPI No
•DP master Yes
• DP slave No
DP master
• Number of connections, max. 8
• Transmission rate, max. 12 Mbit/s
• Number of DP slaves, max. 64
• Services
- PG/OP communication Yes
- Global data communication No
- S7 basic communication No
- S7 communication Yes
- S7 communication, as client Yes
- S7 communication, as server Yes
- Equidistance mode support Yes; Only in conjunction
with isochronous mode
- Isochronous mode Yes
- SYNC/FREEZE Yes
- Activation/deactivation of DP
slaves Yes
- Direct data exchange
(slave-to-slave communication) Yes
- DPV1 Yes
• Address area
- Inputs, max. 16 kbyte
-Outputs, max. 16 kbyte
• User data per DP slave
- Inputs, max. 244 byte
-Outputs, max. 244 byte
2nd interface
Type of interface CP 5613, CP 5613-A2, CP 5603
Max. no. of simultaneously operable
CPs 4
Physics RS 485 / PROFIBUS
Isolated Yes
Functionality
•MPI No
•DP master Yes
• DP slave No
DP master
• Number of connections, max. 50
• Transmission rate, max. 12 Mbit/s
• Number of DP slaves, max. 125
• Services
- PG/OP communication Yes
- Global data communication No
- S7 basic communication No
- S7 communication Yes
- S7 communication, as client Yes
- S7 communication, as server Yes
- Equidistance mode support Yes; Only in conjunction
with isochronous mode
- Isochronous mode Yes
- SYNC/FREEZE Yes
- Activation/deactivation of DP
slaves Yes
- Direct data exchange
(slave-to-slave communication) Yes
- DPV1 Yes
• Address area
- Inputs, max. 16 kbyte
-Outputs, max. 16 kbyte
• User data per DP slave
- Inputs, max. 244 byte
-Outputs, max. 244 byte
6ES7671-0RC08-0YA0
SIMATIC WinAC RTX 2010
ST80_2013_EN_Kap05.book Seite 78 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC PC-based controllers
SIMATIC WinAC RTX
5/79
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
3rd interface
Type of interface PROFINET
Max. no. of simultaneously operable
CPs 1; Intel Pro/1000 (Intel 82571EB,
82573L, 82574L, 82541PI;
non-shared IRQ required);
integrated IE interface
SIMATIC PC 4x7B, 6x7B, 8x7B,
IPC4x7C, IPC6x7C, IPC8x7C
Physics Ethernet
Isolated Yes
Integrated switch No
Number of ports 1
Automatic detection of transmission
speed Yes; 10/100 Mbit/s
Autonegotiation Yes
Autocrossing Yes
Media redundancy
• supported No
Functionality
PROFINET IO Controller Yes
PROFINET IO Device No
PROFINET CBA Yes
PROFINET IO Controller
• Transmission rate, min. 100 Mbit/s
• Transmission rate, max. 100 Mbit/s
Max. number of connectable
IO devices for RT 128
- of which in line, max. 128
• IRT, supported No
Prioritized startup supported Yes
- Number of IO Devices, max. 32
Activation/deactivation of IO Devices Yes
- Maximum number of IO devices
that can be activated/deactivated
at the same time.
8
IO Devices changing during opera-
tion (partner ports), supported Yes
Device replacement without swap
medium Yes
Send cycles 1 ms
• Updating time 1 - 512 ms (minimum value
depends on communication share
set for PROFINET I/O, on the num-
ber of I/O devices, and on the
volume of configured user data)
• Services
- PG/OP communication Yes
- S7 communication Yes
- Isochronous mode No
- Open IE communication Yes
Address area
- Inputs, max. 16 kbyte
-Outputs, max. 16 kbyte
- User data per address area, max. 2kbyte
- User data consistency, max. 256 byte
Open IE communication
• Open IE communication, supported Yes
Number of connections, max. 32
Local port numbers used at the sys-
tem end 0, 20, 21, 23, 25, 80, 102, 135, 161,
8080, 34962, 34963, 34964, 65532,
65533, 65534, 65535
Keep-alive function, supported Yes
6ES7671-0RC08-0YA0
SIMATIC WinAC RTX 2010
4th interface
Type of interface PROFINET
Max. no. of simultaneously operable
CPs 1; CP 1616 (HW release 8 or above),
CP 1604 (HW release 7 or higher),
integrated PN interface of
SIMATIC PC and S7-mEC
Physics Ethernet
Isolated Yes
Integrated switch Yes
Number of ports 3
Automatic detection of transmission
speed Yes; 10/100 Mbit/s
Autonegotiation Yes
Autocrossing Yes
Change of IP address at runtime,
supported Yes
Number of connection resources 32
Media redundancy
•supported Yes
• Switchover time on line break,
typically 200 ms
• Number of stations in the ring, max. 50
Functionality
• PROFINET IO Controller Yes
• PROFINET IO Device No
• PROFINET CBA Yes
PROFINET IO Controller
• Transmission rate, max. 100 Mbit/s
• Max. number of connectable
IO Devices for RT 256
- of which in line, max. 256
• Number of IO devices with IRT
and the option "high flexibility" 64
- of which in line, max. 32
• Number of IO Devices with IRT and
the option "high performance", max. 64
- of which in line, max. 32
• IRT, supported Yes
• Prioritized startup supported Yes
- Number of IO Devices, max. 32
Activation/deactivation of IO Devices Yes
- Maximum number of IO devices
that can be activated/deactivated
at the same time.
8
• IO Devices changing during
operation (partner ports), supported Yes
• Device replacement without swap
medium Yes
• Send cycles 250 µs, 500 µs, 1 ms
•Updating time 0.25...512 depending
on the send cycle
• Services
- PG/OP communication Yes
- S7 communication Yes
- Isochronous mode Yes
- Open IE communication Yes
• Address area
- Inputs, max. 16 kbyte
-Outputs, max. 16 kbyte
- User data per address area, max. 2kbyte
- User data consistency, max. 256 byte
6ES7671-0RC08-0YA0
SIMATIC WinAC RTX 2010
ST80_2013_EN_Kap05.book Seite 79 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC PC-based controllers
SIMATIC WinAC RTX
5/80 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
5
Open IE communication
• Open IE communication, supported Yes
Number of connections, max. 32
Local port numbers used
at the system end 0, 20, 21, 25, 80, 102, 135, 161,
34962, 34963, 34964, 65532,
65533, 65534, 65535
Isochronous mode
Isochronous operation (application
synchronized up to terminal) Yes
Number of DP masters
with isochronous mode 2
User data per isochronous slave, max. 128 byte
equidistance Yes
shortest clock pulse 2.2 ms; 2.2 ms without partial p
rocess image; 2.2 ms with partial
process image
Communication functions
PG/OP communication Yes
Data record routing Yes; Only with CP 5611 or
integrated PROFIBUS interface of
the SIMATIC PC
Global data communication
• supported No
S7 basic communication
• supported No
S7 communication
• supported Yes
•as server Yes
as client Yes
• User data per job, max. 64 kbyte;
When using BSEND/USEND
Open IE communication
•TCP/IP Yes
- Number of connections, max. 32
- Data length for connection type
01H, max. Not supported
- Data length for connection type
11H, max. 65 534 byte
- Data length, max. 65 534 byte
• ISO-on-TCP (RFC1006) Yes
- Number of connections, max. 32
- Data length, max. 65 534 byte
• UDP Yes
- Number of connections, max. 32
- Data length, max. 1 472 byte
Web server
• supported Yes
• Number of HTTP clients 2
• User-defined websites No
6ES7671-0RC08-0YA0
SIMATIC WinAC RTX 2010
PROFINET CBA
(at set setpoint communication load)
Setpoint for the CPU communication
load 20 %
• Number of remote interconnection
partners 64
• Number of functions, master/slave 30
• Total of all Master/Slave connections 1 000
• Data length of all incoming
connections master/slave, max. 6 800 byte
• Data length of all outgoing
connections master/slave, max. 6 800 byte
• Number of device-internal
and PROFIBUS interconnections 500
• Data length of device-internal und
PROFIBUS interconnections, max. 4 000 byte
• Data length per connection, max. 1 400 byte
• Remote interconnections
with acyclic transmission
- Sampling frequency:
Sampling time, min. 500 ms
- Number of incoming
interconnections 100
- Number of outgoing
interconnections 100
- Data length of all incoming
interconnections, max. 2 000 byte
- Data length of all outgoing
interconnections, max. 2 000 byte
- Data length per connection, max. 1 400 byte
• Remote interconnections with cyclic
transmission
- Transmission frequency:
Transmission interval, min. 10 ms
- Number of incoming
interconnections 200
- Number of outgoing
interconnections 200
- Data length of all incoming
interconnections, max. 4 800 byte
- Data length of all outgoing
interconnections, max. 4 800 byte
- Data length per connection, max. 250 byte
• HMI variables via PROFINET
(acyclic)
- Number of stations that can log on
for HMI variables (PN OPC/iMap) 3
- HMI variable updating 500 ms
- Number of HMI variables 200
- Data length of all HMI variables,
max. 2 000 byte
• PROFIBUS proxy functionality
- supported Yes
- Number of linked
PROFIBUS devices 16
- Data length per connection, max. 240 byte; Slave-dependent
Number of connections
•overall 96
6ES7671-0RC08-0YA0
SIMATIC WinAC RTX 2010
ST80_2013_EN_Kap05.book Seite 80 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC PC-based controllers
SIMATIC WinAC RTX
5/81
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
S7 message functions
Number of login stations for message
functions, max. 62
SCAN procedure No
Process diagnostic messages Yes; ALARM_S, ALARM_SQ,
ALARM_D, ALARM_DQ
simultaneously active Alarm-S blocks,
max. 20; of a total of 20 for all SFCs
Alarm 8-blocks Yes
Number of instances for alarm 8
and S7 communication blocks, max. 4 000
Process control messages No
Test commissioning functions
Status block Yes
Single step Yes
Number of breakpoints 20
Status/control
Status/control variable Yes
Forcing
• Forcing No
Diagnostic buffer
•present Yes
Number of entries, max. 3 200
-adjustable Yes
-preset 120
Hardware requirements
Hardware required PC with color monitor, keyboard,
mouse or pointing device for
Windows
Required memory on hard disk, min. 100 Mbyte
Main memory, min. 1 Gbyte; WES7: 2 GB
Processor Intel Celeron M,
900 MHz or compatible
Multi-processor system Yes; Dual Pentium, CoreDuo,
Core2Duo or compatible
• Hyper-threading Yes
6ES7671-0RC08-0YA0
SIMATIC WinAC RTX 2010
Operating systems
Windows NT 4.0 No
Windows 2000 No
Windows XP Yes; Professional, SP2 and SP3
Windows XP embedded Yes; With the delivery image of the
SIMATIC PC
• Supported HAL types
under Windows XP ACPI uniprocessor PC,
ACPI multiprocessor PC,
MPS multiprocessor PC
Windows Vista No
Windows 7 Yes; Professional, Enterprise,
Ultimate (only 32 bits)
Windows embedded Standard 7 Yes
Configuration
programming
• Nesting levels 8
• Programming language
-LAD Yes
-FBD Yes
-STL Yes
-SCL Yes
-CFC Yes
- GRAPH Yes
- HiGraph® Yes
• Software libraries
- Easy Motion Control Yes
Know-how protection
• User program protection/password
protection Yes
Open Development interfaces
• CCX (Custom Code Extension) Yes; WinAC ODK V4.2 or higher
• CMI (Controller Management
Interface) Yes; WinAC ODK V4.2 or higher
• SMX (Shared Memory Extension) Yes; WinAC ODK V4.2 or higher
- Inputs 4kbyte
-Outputs 4kbyte
Weight
Weight, approx. 100 g; With packaging
6ES7671-0RC08-0YA0
SIMATIC WinAC RTX 2010
ST80_2013_EN_Kap05.book Seite 81 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC PC-based controllers
SIMATIC WinAC RTX
5/82 Siemens ST 80 / ST PC · 2013
5
Ordering data
Order No. Order No.
SIMATIC WinAC RTX 2010 6ES7671-0RC08-0YA0
Software PLC for PC-based
automation tasks with stringent
deterministic requirements;
PROFIBUS and PROFINET;
CD-ROM with electronic
documentation d, e, f;
single license, executable under
Windows XP SP2 and SP3
as well as Windows 7 (32 bit)
SIMATIC WinAC RTX 2010
Upgrade 6ES7671-0RC08-0YE0
For upgrading from basic/RTX V3.x,
V4.0, V4.1 2005, 2008 and 2009;
single license, executable under
Windows XP SP2 and SP3 and
Windows 7 (32 bit)
CP 5611 A2
communications processor 6GK1561-1AA01
PCI card (32 bit) for connection
of a programming device or PC
to PROFIBUS
CP 5621
communications processor
PCI Express x1 card (32 bit)
for connection of a programming
device or PC to PROFIBUS
6GK1562-1AA00
PCI Express x1 card (32 bit)
CP 5621 and MPI cable, 5 m 6GK1562-1AM00
CP 5603 Microbox Package 6GK1560-3AU00
Comprising CP 5603 module and
Microbox expansion rack
CP 5613 A2
communications processor 6GK1561-3AA01
PCI card (32 bit; 3.3 V/5 V) for
connection to PROFIBUS incl.
DP-Base software with NCM PC;
DP-RAM interface for DP master,
incl. PG and FDL protocol; single
license for 1 installation, runtime
software, software and electronic
manual on CD-ROM, Class A, for
32 bit Windows 2000 Professional/
Server, Windows XP Professional,
German/English
CP 5623
communications processor 6GK1562-3AA00
PCI Express x1 card (32 bit) for
connection to PROFIBUS incl.
DP-Base software with NCM PC;
DP-RAM interface for DP master or
DP slave, incl. PG and FDL proto-
cols; single license for 1 installation,
runtime software, software and elec-
tronic manual on CD-ROM, Class A,
for operating system support see
SIMATIC NET software;
German/English
CP 1616
communications processor 6GK1161-6AA02
PCI Card (32 bit; 3.3/5 V universal
key) with ASIC ERTEC 400 for
connecting PCs to PROFINET IO
with 4-port real-time switch (RJ45);
incl. IO-Base software for
PROFINET IO controller (RT opera-
tion) and NCM PC; single license for
one installation, runtime software,
software and electronic manual on
CD-ROM, Class A, for 32 bit
Windows XP Professional;
German/English
CP 1604 Microbox Package 6GK1160-4AU00
Package for implementing
the CP 1604 in the
SIMATIC Microbox PC;
comprising the CP 1604, connection
board, power supply and expansion
rack for Microbox PC; for use with
Development Kit DK-16xx PN IO;
NCM PC
ST80_2013_EN_Kap05.book Seite 82 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC PC-based controllers
SIMATIC WinAC RTX
5/83
Siemens ST 80 / ST PC · 2013
More information
Add-ons for SIMATIC WinAC
PC-based Competence Center Cologne
Our add-ons supplement the WinAC RTX soft PLC by useful
functions which have arisen in the context of projects. You can
thus fully utilize the advantages of PC-based automation.
The applications are available in the form of function blocks and
are easy to use without special programming knowledge.
Detailed information and prices can be obtained from your
Siemens contact or from:
Contact:
Siemens AG
Competence Center Cologne
E-mail: CCCologne@siemens.com
Brochures
Information material for downloading can be found in the
Internet:
http://www.siemens.com/simatic/printmaterial
Application Function
WinAC serial driver Communication over
serial interfaces
WinAC PC IO driver Access to central I/O expansion
PC IO including interrupt handling
WinAC SQL Access to SQL databases
WinAC TCP/IP driver Data exchange between WinAC and
other communication partners over
Windows interface using TCP/IP,
UDP, or ISO-on-TCP
WinAC OPC Client Access to various OPC servers
WinAC Shutdown Controlled shutdown of WinAC and
PC system
WinAC File-I/O Reading and writing of DBs as file
on the PC system
WinAC Command Calling of batch commands from
WinAC
WinAC Access-DB High-performance access to DBs,
bit memories or I/O image
WinAC SMX Cover Provision of SMX functions,
e.g. for Delphi or VB
WinAC CMI Wrapper Simple program-based operation
of WinAC
ST80_2013_EN_Kap05.book Seite 83 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC PC-based controllers
SIMATIC WinAC RTX F
5/84 Siemens ST 80 / ST PC · 2013
5
Overview
SIMATIC WinAC RTX F:
Optimized for applications that demand a high degree of
flexibility and integration capability and that must also satisfy
safety requirements up to SIL 3 (IEC 61508).
The software solution for tasks that require hard deterministic
behavior and high performance.
With real-time expansion for assuring deterministic behavior
for the control section.
Distributed I/O can be connected over PROFIBUS and/or
PROFINET, also safety-related over PROFIsafe.
Technical specifications
6ES7671-1RC08-0YA0
SIMATIC WinAC RTX F 2010
General information
Hardware product version -
Firmware version V4.6
Engineering with
• Programming package STEP 7 V5.5 or higher + hardware
update / iMap V3.0 SP1 / option
package S7 Distributed Safety V5.4
+ SP5 / S7 F Configuration Pack
V5.5 + SP6 + HF1
Memory
Work memory
• integrated (for program) 4 Mbyte; Adjustable; depends on
Non Paged Memory Pool
• integrated (for data) 4 Mbyte; Adjustable; depends on
Non Paged Memory Pool
Load memory
• integrated RAM, max. Adjustable; depends on
Non Paged Memory Pool
CPU processing times
for bit operations, typ. 0.004 µs; typ.
for fixed point arithmetic, typ. 0.003 µs; typ.
for floating point arithmetic, typ. 0.004 µs; typ.
Reference platform Pentium IV, 2.4 GHz
CPU-blocks
DB
•Number, max. 65 535; Limited only
by RAM set for data
•Size, max. 64 kbyte
FB
•Number, max. 65 536; Limited only
by RAM set for code
•Size, max. 64 kbyte
FC
•Number, max. 65 536; Limited only
by RAM set for code
•Size, max. 64 kbyte
OB
•Size, max. 64 kbyte
Nesting depth
• per priority class 24
• additional within an error OB 24
Counters, timers and
their retentivity
S7 counter
•Number 2 048
• Retentivity
-adjustable Yes
- lower limit 0
-upper limit 2 047
-preset 8
• Counting range
-adjustable Yes
- lower limit 0
-upper limit 999
IEC counter
• present Yes
• Type SFB
•Number Unlimited
(limited only by RAM capacity)
ST80_2013_EN_Kap05.book Seite 84 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC PC-based controllers
SIMATIC WinAC RTX F
5/85
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
S7 times
•Number 2 048
• Retentivity
-adjustable Yes
- lower limit 0
-upper limit 2 047
-preset 0
•Time range
- lower limit 10 ms
-upper limit 9 990 s
IEC timer
•present Yes
•Type SFB
•Number Unlimited
(limited only by RAM capacity)
Data areas and their retentivity
Retentivity without
UPS and PS Extension Board 128 kbyte with SIMATIC IPC427C
and HMI IPC477C;
further SIMATIC PCs on request
Retentivity with UPS all data
Flag
•Number, max. 16 kbyte
• Retentivity preset MB 0 to MB 15
Number of clock memories 8
Data blocks
• Retentivity adjustable Yes; via non-retain property on DB
• Retentivity preset Yes
Local data
• adjustable, max. 64 kbyte
•preset 32 kbyte
per priority class, max. 61 440 byte
Address area
I/O address area
• Inputs 16 kbyte
•Outputs 16 kbyte
• of which, distributed
- DP interface, inputs 16 kbyte
- DP interface, outputs 16 kbyte
- PN interface, inputs 16 kbyte
- PN interface, outputs 16 kbyte
Process image
• Inputs, adjustable 8kbyte
Outputs, adjustable 8kbyte
• Inputs, default 512 byte
Outputs, default 512 byte
Subprocess images
Number of subprocess images, max. 15
Digital channels
• Inputs 128 000
•Outputs 128 000
Analog channels
• Inputs 8 000
•Outputs 8 000
6ES7671-1RC08-0YA0
SIMATIC WinAC RTX F 2010
Hardware configuration
Submodules
• Number of submodules, max 4
• of which PROFIBUS, max. 4; Supported interfaces:
see 1st and 2nd interface
• of which Industrial Ethernet, max. 1; Supported interfaces:
see 3rd and 4th interface
Number of operable FMs and CPs
(recommended)
•FM 4; FM distributed: FM 350-1,
FM 350-2, FM 351, FM 352 /
FM 352-5, FM 353, FM 354,
FM 355, FM 355-2
• CP, point-to-point 2; CP 340, CP 341 distributed
•CP, LAN Over PC CP
Time of day
Clock
• Hardware clock (real-time clock) Yes
• battery-backed and synchronizable Yes
Operating hours counter
•Number 8
Clock synchronization
•supported Yes
• to PC-CP, slave Yes
• on Ethernet via NTP Yes
1st interface
Type of interface CP 5611-A2, CP 5621, integrated
PB interface of the SIMATIC PC
Max. no. of simultaneously
operable CPs 1
Physics RS 485 / PROFIBUS
Isolated Yes
Power supply to interface
(15 to 30 V DC), max. does not exist
Number of connection resources 8
Functionality
•MPI No
•DP master Yes
• DP slave No
DP master
• Number of connections, max. 8
• Transmission rate, max. 12 Mbit/s
• Number of DP slaves, max. 64
• Services
- PG/OP communication Yes
- Global data communication No
- S7 basic communication No
- S7 communication Yes
- S7 communication, as client Yes
- S7 communication, as server Yes
- Equidistance mode support Yes; Only in conjunction
with isochronous mode
- Isochronous mode Yes
- SYNC/FREEZE Yes
- Activation/deactivation of DP
slaves Yes
- Direct data exchange (slave-to-
slave communication) Yes
- DPV1 Yes
• Address area
- Inputs, max. 16 kbyte
-Outputs, max. 16 kbyte
• User data per DP slave
- Inputs, max. 244 byte
-Outputs, max. 244 byte
6ES7671-1RC08-0YA0
SIMATIC WinAC RTX F 2010
ST80_2013_EN_Kap05.book Seite 85 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC PC-based controllers
SIMATIC WinAC RTX F
5/86 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
5
2nd interface
Type of interface CP 5613, CP 5613-A2, CP 5603,
CP 5623
Max. no. of simultaneously operable
CPs 4
Physics RS 485 / PROFIBUS
Isolated Yes
Functionality
•MPI No
•DP master Yes
•DP slave No
DP master
Number of connections, max. 50
• Transmission rate, max. 12 Mbit/s
Number of DP slaves, max. 125
• Services
- PG/OP communication Yes
- Global data communication No
- S7 basic communication No
- S7 communication Yes
- S7 communication, as client Yes
- S7 communication, as server Yes
- Equidistance mode support Yes; Only in conjunction
with isochronous mode
- Isochronous mode Yes
- SYNC/FREEZE Yes
- Activation/deactivation of DP
slaves Yes
- Direct data exchange
(slave-to-slave communication) Yes
- DPV1 Yes
Address area
- Inputs, max. 16 kbyte
-Outputs, max. 16 kbyte
• User data per DP slave
- Inputs, max. 244 byte
-Outputs, max. 244 byte
3rd interface
Type of interface PROFINET
Max. no. of simultaneously
operable CPs 1; Intel Pro/1000 (Intel 82571EB,
82573L, 82574L, 82541PI;
non-shared IRQ required);
integrated IE interface
SIMATIC PC 4x7B, 6x7B, 8x7B,
IPC4x7C, IPC6x7C, IPC8x7C
Physics Ethernet
Isolated Yes
Integrated switch No
Number of ports 1
Automatic detection of transmission
speed Yes; 10/100 Mbit/s
Autonegotiation Yes
Autocrossing Yes
Media redundancy
• supported No
Functionality
PROFINET IO Controller Yes
PROFINET IO Device No
PROFINET CBA Yes
6ES7671-1RC08-0YA0
SIMATIC WinAC RTX F 2010
PROFINET IO Controller
• Transmission rate, min. 100 Mbit/s
• Transmission rate, max. 100 Mbit/s
• Number of connectable IO devices,
max. 128
• Max. number of connectable
IO devices for RT 128
- of which in line, max. 128
• IRT, supported No
• Prioritized startup supported Yes
- Number of IO Devices, max. 32
• Activation/deactivation of
IO Devices Yes
- Maximum number of IO devices
that can be activated/deactivated
at the same time.
8
• IO Devices changing during opera-
tion (partner ports), supported Yes
• Device replacement without swap
medium Yes
• Send cycles 1 ms
•Updating time 1 - 512 ms (minimum value depends
on communication share set for
PROFINET I/O, on the number of
I/O devices, and on the volume of
configured user data)
• Services
- PG/OP communication Yes
- S7 communication Yes
- Isochronous mode No
- Open IE communication Yes
• Address area
- Inputs, max. 16 kbyte
-Outputs, max. 16 kbyte
- User data per address area, max. 2kbyte
- User data consistency, max. 256 byte
Open IE communication
• Open IE communication, supported Yes
• Number of connections, max. 32
• Local port numbers used at the
system end 0, 20, 21, 23, 25, 80, 102, 135, 161,
8080, 34962, 34963, 34964, 65532,
65533, 65534, 65535
• Keep-alive function, supported Yes
4th interface
Type of interface PROFINET
Max. no. of simultaneously
operable CPs 1; CP 1616 (HW release 8 or above),
CP 1604 (HW release 7 or higher),
integrated PN interface of
SIMATIC PC and S7-mEC
Physics Ethernet
Isolated Yes
Integrated switch Yes
Number of ports 3
Automatic detection of transmission
speed Yes; 10/100 Mbit/s
Autonegotiation Yes
Autocrossing Yes
Change of IP address at runtime,
supported Yes
Number of connection resources 32
6ES7671-1RC08-0YA0
SIMATIC WinAC RTX F 2010
ST80_2013_EN_Kap05.book Seite 86 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC PC-based controllers
SIMATIC WinAC RTX F
5/87
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
Media redundancy
• supported Yes
Switchover time on line break,
typically 200 ms
Number of stations in the ring, max. 50
Functionality
PROFINET IO Controller Yes
PROFINET IO Device No
PROFINET CBA Yes
PROFINET IO Controller
• Transmission rate, max. 100 Mbit/s
Max. number of connectable
IO Devices for RT 256
- of which in line, max. 256
Number of IO devices with IRT and
the option "high flexibility" 64
- of which in line, max. 32
Number of IO Devices with IRT and
the option "high performance", max. 64
- of which in line, max. 64
• IRT, supported Yes
Prioritized startup supported Yes
- Number of IO Devices, max. 32
Activation/deactivation of IO Devices Yes
- Maximum number of IO devices
that can be activated/deactivated
at the same time.
8
IO Devices changing during opera-
tion (partner ports), supported Yes
Device replacement without
swap medium Yes
Send cycles 250 µs, 500 µs, 1 ms
• Updating time 0.25...512 depending on the send
cycle
• Services
- PG/OP communication Yes
- S7 communication Yes
- Isochronous mode Yes
- Open IE communication Yes
Address area
- Inputs, max. 16 kbyte
-Outputs, max. 16 kbyte
- User data per address area, max. 2kbyte
- User data consistency, max. 256 byte
Open IE communication
• Open IE communication, supported Yes
Number of connections, max. 32
Local port numbers used at the
system end 0, 20, 21, 25, 80, 102, 135, 161,
34962, 34963, 34964, 65532,
65533, 65534, 65535
Isochronous mode
Isochronous operation (application
synchronized up to terminal) Yes
Number of DP masters
with isochronous mode 2
User data per isochronous slave, max. 128 byte
equidistance Yes
shortest clock pulse 2.2 ms; 2.2 ms without partial
process image; 2.2 ms with partial
process image
6ES7671-1RC08-0YA0
SIMATIC WinAC RTX F 2010
Communication functions
PG/OP communication Yes
Data record routing Yes; Only with CP 5611 or
integrated PROFIBUS interface
of the SIMATIC PC
Global data communication
•supported No
S7 basic communication
•supported No
S7 communication
•supported Yes
•as server Yes
• as client Yes
• User data per job, max. 64 kbyte; Depends on which block
is used: BSEND/USEND or PUT/GET
Open IE communication
•TCP/IP Yes
- Number of connections, max. 32
- Data length for connection type
01H, max. Not supported
- Data length for connection type
11H, max. 65 534 byte
- Data length, max. 65 534 byte
• ISO-on-TCP (RFC1006) Yes
- Number of connections, max. 32
- Data length, max. 65 534 byte
• UDP Yes
- Number of connections, max. 32
- Data length, max. 1 472 byte
Web server
•supported Yes
• Number of HTTP clients 2
• User-defined websites No
PROFINET CBA (at set setpoint
communication load)
Setpoint for the CPU communication
load 20 %
• Number of remote interconnection
partners 64
• Number of functions, master/slave 30
• Total of all Master/Slave connections 1 000
• Data length of all incoming
connections master/slave, max. 6 800 byte
• Data length of all outgoing
connections master/slave, max. 6 800 byte
• Number of device-internal
and PROFIBUS interconnections 500
• Data length of device-internal und
PROFIBUS interconnections, max. 4 000 byte
• Data length per connection, max. 1 400 byte
• Remote interconnections with
acyclic transmission
- Sampling frequency:
Sampling time, min. 500 ms
- Number of incoming
interconnections 100
- Number of outgoing
interconnections 100
- Data length of all incoming
interconnections, max. 2 000 byte
- Data length of all outgoing
interconnections, max. 2 000 byte
- Data length per connection, max. 1 400 byte
6ES7671-1RC08-0YA0
SIMATIC WinAC RTX F 2010
ST80_2013_EN_Kap05.book Seite 87 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC PC-based controllers
SIMATIC WinAC RTX F
5/88 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
5
• Remote interconnections
with cyclic transmission
- Transmission frequency:
Transmission interval, min. 10 ms
- Number of incoming
interconnections 200
- Number of outgoing
interconnections 200
- Data length of all incoming
interconnections, max. 4 800 byte
- Data length of all outgoing
interconnections, max. 4 800 byte
- Data length per connection, max. 250 byte
HMI variables via PROFINET
(acyclic)
- Number of stations that can log on
for HMI variables (PN OPC/iMap) 3
- HMI variable updating 500 ms
- Number of HMI variables 200
- Data length of all HMI variables,
max. 2 000 byte
PROFIBUS proxy functionality
- supported Yes
- Number of linked
PROFIBUS devices 16
- Data length per connection, max. 240 byte; Slave-dependent
Number of connections
•overall 96
S7 message functions
Number of login stations for message
functions, max. 62
SCAN procedure No
Process diagnostic messages Yes; ALARM_S, ALARM_SQ,
ALARM_D, ALARM_DQ
simultaneously active Alarm-S blocks,
max. 20; of a total of 20 for all SFCs
Alarm 8-blocks Yes
Number of instances for alarm 8 and
S7 communication blocks, max. 4 000
Process control messages No
Test commissioning functions
Status block Yes
Single step Yes
Number of breakpoints 20
Status/control
Status/control variable Yes
Forcing
• Forcing No
Diagnostic buffer
•present Yes
Number of entries, max. 3 200
-adjustable Yes
-preset 120
6ES7671-1RC08-0YA0
SIMATIC WinAC RTX F 2010
Hardware requirements
Hardware required PC with color monitor, keyboard,
mouse or pointing device for
Windows
Required memory on hard disk, min. 100 Mbyte
Main memory, min. 1Gbyte
Processor Intel Celeron M 900 MHz or
compatible (older PC systems with
Programmable Interrupt Controllers
(PIC) are not suitable for
WinAC RTX F 2010.)
• Multi-processor system No
• Hyper-threading Yes
Operating systems
Windows NT 4.0 No
Windows 2000 No
Windows XP Yes; Professional, SP2 and SP3
Windows XP embedded Yes; With the delivery image of the
SIMATIC PC
• Supported HAL types
under Windows XP ACPI uniprocessor PC,
ACPI multiprocessor PC,
MPS multiprocessor PC
Windows Vista No
Windows 7 Yes; Professional, Enterprise,
Ultimate (only 32 bits)
Windows embedded Standard 7 No
Configuration
programming
• Nesting levels 8
• Programming language
-LAD Yes
-FBD Yes
-STL Yes
-SCL Yes
-CFC Yes
- GRAPH Yes
- HiGraph® Yes
• Software libraries
- Easy Motion Control Yes
Know-how protection
• User program protection/password
protection Yes
• Block encryption No
Open Development interfaces
• CCX (Custom Code Extension) Yes; WinAC ODK V4.2 or higher
• CMI (Controller Management
Interface) Yes; WinAC ODK V4.2 or higher
• SMX (Shared Memory Extension) Yes; WinAC ODK V4.2 or higher
- Inputs 4kbyte
-Outputs 4kbyte
Weight
Weight, approx. 100 g; With packaging
6ES7671-1RC08-0YA0
SIMATIC WinAC RTX F 2010
ST80_2013_EN_Kap05.book Seite 88 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC PC-based controllers
SIMATIC WinAC RTX F
5/89
Siemens ST 80 / ST PC · 2013
Ordering data
Order No.
More information
Add-ons for SIMATIC WinAC
PC-based Competence Center Cologne
Our add-ons supplement the WinAC RTX soft PLC by useful
functions which have arisen in the context of projects. In this
way, you can fully utilize the advantages of PC based
Automation.
The applications are available in the form of function blocks and
are easy to use without special programming knowledge.
Detailed information and prices can be obtained from your
Siemens contact or from:
Contact:
Siemens AG
Competence Center Cologne
E-mail: CCCologne@siemens.com
Brochures
Information material is available for downloading in the Internet
at:
http://www.siemens.com/simatic/printmaterial
SIMATIC WinAC RTX F 2010 6ES7671-1RC08-0YA0
SIMATIC WinAC RTX F 2010
upgrade 6ES7671-1RC08-0YE0
CP 5611 A2
communications processor 6GK1561-1AA01
PCI card (32 bit) for connection
of a programming device or PC
to PROFIBUS
CP 5621
communications processor
PCI Express x1 card (32 bit) for
connection of a programming
device or PC to PROFIBUS
6GK1562-1AA00
PCI Express x1 card (32 bit)
CP 5621 and MPI cable, 5 m 6GK1562-1AM00
CP 5603 Microbox Package 6GK1560-3AU00
Comprising CP 5603 module and
Microbox expansion rack
CP 5613 A2
communications processor 6GK1561-3AA01
PCI card (32 bit; 3.3 V/5 V) for
connection to PROFIBUS incl.
DP-Base software with NCM PC;
DP-RAM interface for DP master,
incl. PG and FDL protocol; single
license for 1 installation, runtime
software, software and electronic
manual on CD-ROM, Class A, for
32 bit Windows 2000 Professional/
Server, Windows XP Professional,
German/English
CP 5623
communications processor 6GK1562-3AA00
PCI Express x1 card (32 bit) for
connection to PROFIBUS incl.
DP-Base software with NCM PC;
DP-RAM interface for DP master or
DP slave, incl. PG and FDL proto-
cols; single license for 1 installation,
runtime software, software and elec-
tronic manual on CD-ROM, Class A,
for operating system support see
SIMATIC NET software;
German/English
CP 1616
communications processor 6GK1161-6AA02
PCI Card (32 bit; 3.3/5 V universal
key) with ASIC ERTEC 400 for
connecting PCs to PROFINET IO
with 4-port real-time switch (RJ45);
incl. IO-Base software for
PROFINET IO controller (RT opera-
tion) and NCM PC; single license for
one installation, runtime software,
software and electronic manual on
CD-ROM, Class A, for 32 bit
Windows XP Professional;
German/English
CP 1604 Microbox Package 6GK1160-4AU00
Package for implementing the
CP 1604 in the SIMATIC Microbox
PC; comprising the CP 1604,
connection board, power supply
and expansion rack for
Microbox PC; for use with Develop-
ment Kit DK-16xx PN IO; NCM PC
Application Function
WinAC serial driver Communication over
serial interfaces
WinAC PC IO driver Access to central I/O expansion
PC IO including interrupt handling
WinAC SQL Access to SQL databases
WinAC TCP/IP driver Data exchange between WinAC and
other communication partners over
Windows interface using TCP/IP,
UDP, or ISO-on-TCP
WinAC OPC Client Access to various OPC servers
WinAC Shutdown Controlled shutdown of WinAC and
the PC system
WinAC File I/O Reading and writing of DBs as a
file on the PC system
WinAC Command Calling batch commands from
WinAC
WinAC Access DB High-performance accesses to DBs,
bit memories or I/O image
WinAC SMX Cover Provides SMX functions,
e.g. for Delphi or VB
WinAC CMI Wrapper Easy program-controlled operation
of WinAC
ST80_2013_EN_Kap05.book Seite 89 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SIMATIC PC-based controllers
SIMATIC WinAC ODK
5/90 Siemens ST 80 / ST PC · 2013
5
Overview
SIMATIC WinAC software PLCs support powerful interfaces
which permit close meshing of the control task with PC-based
applications.
WinAC ODK allows the user to develop applications or to
integrate already existing applications into the control task.
New with WinAC ODK V4.2:
CCX interface:
- New SFB 65003 for asynchronous execution of
ODK applications
- Expansion of data access functions
- Creation of Windows DLL with C# and VB
SMX interface:
- Access to the Shared Memory interface under
IntervalZero RTX
- Expansion of data access functions
- Creation of Windows applications with C# and VB
Supports MS Visual Studio 2005 and 2008 (under Windows)
Technical specifications
Ordering data
Order No.
More information
Brochures
Information material for downloading can be found in the
Internet:
http://www.siemens.com/simatic/printmaterial
6ES7806-1CC03-0BA0
SIMATIC WinAC ODK V4.2
Hardware requirements
Hardware required PC with color monitor, keyboard,
mouse or pointing device for
Windows
Required memory on hard disk, min. 30 Mbyte
Main memory, min. 512 Mbyte
Processor Intel Pentium 800 MHz
Operating systems
Windows XP Yes; Professional, SP2 and SP3
Configuration
Open Development interfaces
• CCX (Custom Code Extension) Yes; WinAC RTX 2008 (V4.4) or
higher; programming languages:
Microsoft Visual C++ V6.0 SP5 or
higher, .net 2003, 2005, 2008;
Microsoft Visual Basic 2005, 2008;
Microsoft Visual C# 2005, 2008
• CMI (Controller Management
Interface) Yes; WinAC RTX 2005 SP2 (V4.3) or
higher; programming languages:
Microsoft Visual C++ V6.0 SP5 or
higher, .net 2003, 2005, 2008;
Microsoft Visual Basic V6.0 SP5 or
higher, .net 2003, 2005, 2008;
Microsoft Visual C# .net 2003, 2005,
2008
• SMX (Shared Memory Extension) Yes; WinAC RTX 2008 (V4.4) or
higher; programming languages:
Microsoft Visual C++ V6.0 SP5 or
higher, .net 2003, 2005, 2008;
Microsoft Visual Basic 2005, 2008;
Microsoft Visual C# 2005, 2008
Weight
Weight, approx. 200 g
SIMATIC WinAC ODK V4.2 6ES7806-1CC03-0BA0
for integration of C/C++ code in
WinAC PLCs, executable under
Windows XP SP2 or SP3; CD-ROM
with electronic documentation
Single license
ST80_2013_EN_Kap05.book Seite 90 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Embedded Controller
Embedded Controller
5/91
Siemens ST 80 / ST PC · 2013
Overview
An embedded PC or embedded device is combined with
automation software (e.g. software PLC, HMI system, etc.) and
is ready-for-use.
Windows Embedded Standard or Windows Embedded
Compact is used as the operating system.
PC-based Automation comprises:
•Control
• Technology
• Visualization
Data processing
• Communication
• Fail-safe
on a common embedded PC platform.
S7-mEC
SIMATIC S7-mEC is a modular controller in S7-300 design with
powerful embedded PC technology. The embedded controller
combines the advantages of the tried-and-tested modular S7
controller with PC technology in one new device.
SIMATIC S7-mEC RTX is characterized by:
Maximum ruggedness without fan or hard disk
Modular expansion options, e.g. central expansion
with S7-300 I/O or PC interfaces
Commissioning, as for S7-300, by automation specialists
SIMATIC WinAC RTX or alternatively WinAC RTX F preinstalled
as a software PLC.
SIMATIC IPC bundles
The SIMATIC IPC bundles are ready-to-use, combined
embedded PCs with the following SIMATIC software options:
SIMATIC WinAC RTX
SIMATIC WinAC RTX F
SIMATIC WinCC flexible or WinCC RT Advanced
Combinations with WinAC and WinCC
SIMATIC IPC227D and IPC277D bundles
SIMATIC IPC227D and SIMATIC IPC277D are also available with
ready-to-use, pre-installed SIMATIC software:
SIMATIC WinCC RT Advanced
SIMATIC WinAC RTX
SIMATIC WinAC RTX F
Combinations of SIMATIC WinAC (F) and WinCC
The panels are available in 7", 9", 12", 15" and 19" TFT touch
operation. With their compact structure, these SIMATIC IPCs are
the ideal solution for simple control and HMI tasks on a single
platform and also offer the openness of a PC-based system.
SIMATIC IPC477C bundles
As in the case of SIMATIC IPC427C, the SIMATIC HMI IPC477C
can also be ordered with ready-to-use, pre-installed
SIMATIC software:
SIMATIC WinCC flexible or WinCC RT Advanced
SIMATIC WinAC RTX
SIMATIC WinAC RTX F
Combinations of SIMATIC WinAC RTX (F) and WinCC
The panels are available in 12", 15" and 19" front variants,
optionally with touch or key functionality. With their compact
structure, Panel PCs are the ideal solution for complex control
and HMI tasks on a single platform and also offer the openness
of a PC-based system.
SIMATIC IPC477D bundles
As in the case of SIMATIC IPC427D, the SIMATIC IPC477D can
also be ordered with ready-to-use, pre-installed SIMATIC
software:
SIMATIC WinCC RT Advanced
SIMATIC WinAC RTX
SIMATIC WinAC RTX F
Combinations of SIMATIC WinAC RTX (F) and WinCC
The panels are available in 12" TFT Touch, 15" TFT Touch, 15"
TFT Touch/Key, 19" TFT Touch and 22" TFT Touch front variants.
With their compact structure, Panel PCs are the ideal solution for
complex control and HMI tasks on a single platform and also
offer the openness of a PC-based system.
ST80_2013_EN_Kap05.book Seite 91 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Embedded Controller
Embedded Controller
5/92 Siemens ST 80 / ST PC · 2013
More information (continued)
5
Decision aid for the use of embedded systems
• Applies
o Applies under certain conditions
- Does not apply
More information
Brochures
Information material for downloading can be found in the
Internet:
http://www.siemens.com/simatic/printmaterial
Customer benefits Modular Control PC-based Automation
SIMATIC S7 S7 Modular
Embedded
Controller
(S7-mEC)
IPC227D,
IPC277D bundles IPC427C/D bundles,
HMI IPC477C/
IPC477D bundles
on SIMATIC PC
Design
Ruggedness • • •••• (depends on hard-
ware configuration)
Type of construction Modular Modular Compact Compact Depending on the
type of construction
Spare parts availability
(beyond date of discontinuation) 10 years 5 years 5 years 5 years 5 years
Performance
Fast restart after power failure - - - -
Hard real-time • • • • • • • • • •
Fast program processing • • • •
(depending on
processor)
• •
(depending on
processor)
• • •
(depending on
processor)
Safety Integrated • •
(option) • •
(option) • •
(option) • •
I/O interfacing
Central/distributed • • / • • • / • • - / • • • / • •
4x7D: - / • • - / • •
User know-how
Preconfigured, turnkey ••••-
Previous knowledge
PLC • • • • • • • •
PC - • • • • • • •
HMI - o o o • •
Openness
Openness
Integration of C++ programs
• Further processing of data using
external programs via OPC on a
hardware platform
- • • • •
Modularization with distributed
intelligence (CBA) •••••
Integration of PLC and HMI on one
hardware platform - • • • •
ST80_2013_EN_Kap05.book Seite 92 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Embedded Controller
EC31
5/93
Siemens ST 80 / ST PC · 2013
Overview
Get off to a fast start in automation solutions with embedded
PC platforms.
- Ready-to-use SIMATIC WinAC RTX or WinAC RTX F
preinstalled on EC31
- Prepared for use in a SIMATIC environment with
PROFINET and Industrial Ethernet
- Commissioning by specialist automation personnel as with
the S7-300
- Configuring and programming with SIMATIC STEP 7 over
Industrial Ethernet
- Optional visualization
Modular expansion capability:
Central expansion with
- S7-300 I/O (SM modules of S7-300)
- Expansion modules for additional PC interfaces, e.g. DVI-I,
USB, Gigabit Ethernet networks and memory card slots,
as well as PCI-104
Rugged operation
- Hard-disk-free operation based on flash disk and Windows
Embedded Standard
- Fan-free operation
Flexibility of a PC-based automation environment
- Free memory space on flash disk can be used for other
PC applications
- Use of WinAC ODK with SIMATIC WinAC RTX and
WinAC RTX F (read-only in safety-related program part)
- Connection option for USB devices
- Memory capacity expandable using multimedia card
Data retentivity for WinAC RTX and RTX F without
uninterruptible power supply (UPS)
Technical specifications
6ES7677-1DD10-
0BA0 6ES7677-1DD10-
0BB0 6ES7677-1FD10-
0FB0 6ES7677-1DD10-
0BF0 6ES7677-1DD10-
0BG0 6ES7677-1DD10-
0BH0
SIMATIC
S7-mEC, EC31 S7-mEC,
EC31-RTX S7-mEC,
EC31-RTX F S7-mEC, EC31-
HMI/RTX 128PT S7-mEC, EC31-
HMI/RTX 512PT S7-mEC, EC31-
HMI/RTX 2048PT
General information
Hardware product version 01 01 01 01 01 01
Firmware version V2.0 V2.0 V2.0 V2.0 V2.0 V2.0
PC configuration
Computer platform SIMATIC S7 mod-
ular embedded
controller
SIMATIC S7 mod-
ular embedded
controller
SIMATIC S7 mod-
ular embedded
controller
SIMATIC S7 mod-
ular embedded
controller
SIMATIC S7 mod-
ular embedded
controller
SIMATIC S7 mod-
ular embedded
controller
Processor selection Intel Core Duo
1.2 GHz Intel Core Duo
1.2 GHz Intel Core Duo
1.2 GHz Intel Core Duo
1.2 GHz Intel Core Duo
1.2 GHz Intel Core Duo
1.2 GHz
Main memory 1 GB RAM 1 GB RAM 1 GB RAM 1 GB RAM 1 GB RAM 1 GB RAM
Operating systems Windows Embed-
ded Standard
2009
Windows Embed-
ded Standard
2009
Windows Embed-
ded Standard
2009
Windows Embed-
ded Standard
2009
Windows Embed-
ded Standard
2009
Windows Embed-
ded Standard
2009
Installed software
• Visualization WinCC flexible
RT 2008 SP2,
incl. Sm@rtAc-
cess, recipes,
archives options
WinCC flexible
RT 2008 SP2,
incl. Sm@rtAc-
cess, recipes,
archives options
WinCC flexible
RT 2008 SP2,
incl. Sm@rtAc-
cess, recipes,
archives options
• Control SIMATIC WinAC
RTX 2010 SIMATIC WinAC
RTX F 2010 SIMATIC WinAC
RTX 2010 SIMATIC WinAC
RTX 2010 SIMATIC WinAC
RTX 2010
• Communication Yes Yes Yes Yes Yes
Power losses
Power loss, typ. 34 W 34 W 34 W 34 W 34 W 34 W
ST80_2013_EN_Kap05.book Seite 93 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Embedded Controller
EC31
5/94 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
5
Memory
Memory type 256 KB non-vola-
tile memory for
retentive data
512 KB non-vola-
tile memory for
retentive data
512 KB non-vola-
tile memory for
retentive data
512 KB non-vola-
tile memory for
retentive data
512 KB non-vola-
tile memory for
retentive data
512 KB non-vola-
tile memory for
retentive data
Work memory
• integrated 1Gbyte 1Gbyte 1Gbyte 1Gbyte 1Gbyte 1Gbyte
CPU processing times
for bit operations, typ. 0.004 µs; typ. 0.004 µs; typ. 0.004 µs; typ. 0.004 µs; typ. 0.004 µs; typ.
for fixed point arithmetic, typ. 0.003 µs; typ. 0.003 µs; typ. 0.003 µs; typ. 0.003 µs; typ. 0.003 µs; typ.
for floating point arithmetic, typ. 0.004 µs; typ. 0.004 µs; typ. 0.004 µs; typ. 0.004 µs; typ. 0.004 µs; typ.
CPU-blocks
DB
•Number, max. Max. code size
and max. data
size: 4 MB each
Max. code size
and max. data
size: 4 MB each
Max. code size
and max. data
size: 4 MB each
Max. code size
and max. data
size: 4 MB each
Max. code size
and max. data
size: 4 MB each
•Size, max. 64 kbyte 64 kbyte 64 kbyte 64 kbyte 64 kbyte
FB
•Number, max. Max. code size
and max. data
size: 4 MB each
Max. code size
and max. data
size: 4 MB each
Max. code size
and max. data
size: 4 MB each
Max. code size
and max. data
size: 4 MB each
Max. code size
and max. data
size: 4 MB each
•Size, max. 64 kbyte 64 kbyte 64 kbyte 64 kbyte 64 kbyte
FC
•Number, max. Max. code size
and max. data
size: 4 MB each
Max. code size
and max. data
size: 4 MB each
Max. code size
and max. data
size: 4 MB each
Max. code size
and max. data
size: 4 MB each
Max. code size
and max. data
size: 4 MB each
•Size, max. 64 kbyte 64 kbyte 64 kbyte 64 kbyte 64 kbyte
OB
•Size, max. 64 kbyte 64 kbyte 64 kbyte 64 kbyte 64 kbyte
• Number of startup OBs 2; OB 100, 102 2; OB 100, 102 2; OB 100, 102 2; OB 100, 102 2; OB 100, 102
Number of asynchronous error OBs 7; OB 80, 82-85,
86, 88 7; OB 80, 82-85,
86, 88 7; OB 80, 82-85,
86, 88 7; OB 80, 82-85,
86, 88 7; OB 80, 82-85,
86, 88
• Number of synchronous error OBs 2; OB 121, 122 2; OB 121, 122 2; OB 121, 122 2; OB 121, 122 2; OB 121, 122
Nesting depth
per priority class 24 24 24 24 24
• additional within an error OB 24 24 24 24 24
Counters, timers and
their retentivity
S7 counter
•Number 2048 2 048 2 048 2048 2 048
• Retentivity
-adjustable Yes Yes Yes Yes Yes
- lower limit 0 0 0 0 0
-upper limit 2047 2 047 2 047 2047 2 047
-preset 8 8 8 8 8
Counting range
-adjustable Yes Yes Yes Yes Yes
- lower limit 0 0 0 0 0
-upper limit 999 999 999 999 999
IEC counter
•present Yes Yes Yes Yes Yes
•Type SFB SFB SFB SFB SFB
6ES7677-1DD10-
0BA0 6ES7677-1DD10-
0BB0 6ES7677-1FD10-
0FB0 6ES7677-1DD10-
0BF0 6ES7677-1DD10-
0BG0 6ES7677-1DD10-
0BH0
SIMATIC
S7-mEC, EC31 S7-mEC,
EC31-RTX S7-mEC,
EC31-RTX F S7-mEC, EC31-
HMI/RTX 128PT S7-mEC, EC31-
HMI/RTX 512PT S7-mEC, EC31-
HMI/RTX 2048PT
ST80_2013_EN_Kap05.book Seite 94 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Embedded Controller
EC31
5/95
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
S7 times
•Number 2048 2 048 2 048 2048 2 048
• Retentivity
-adjustable Yes Yes Yes Yes Yes
- lower limit 0 0 0 0 0
-upper limit 2047 2 047 2 047 2047 2 047
•Time range
- lower limit 10 ms 10 ms 10 ms 10 ms 10 ms
-upper limit 9990s 9 990 s 9 990 s 9990s 9 990 s
IEC timer
•present Yes Yes Yes Yes Yes
•Type SFB SFB SFB SFB SFB
Data areas and their retentivity
retentive data area, total 512 KB 512 KB 512 KB 512 KB 512 KB
Flag
•Number, max. 16 kbyte 16 kbyte 16 kbyte 16 kbyte 16 kbyte
• Retentivity preset MB 0 to MB 15 MB 0 to MB 15 MB 0 to MB 15 MB 0 to MB 15 MB 0 to MB 15
Number of clock memories 8 8 8 8 8
Address area
I/O address area
• Inputs 16 kbyte 16 kbyte 16 kbyte 16 kbyte 16 kbyte
•Outputs 16 kbyte 16 kbyte 16 kbyte 16 kbyte 16 kbyte
• of which, distributed
- Inputs 8kbyte 8kbyte 8kbyte 8kbyte 8kbyte
-Outputs 8kbyte 8kbyte 8kbyte 8kbyte 8kbyte
Process image
• Inputs, adjustable 16 kbyte 16 kbyte 8kbyte 8kbyte 8kbyte
Outputs, adjustable 16 kbyte 16 kbyte 8kbyte 8kbyte 8kbyte
• Inputs, default 512 byte 512 byte 512 byte 512 byte 512 byte
Outputs, default 512 byte 512 byte 512 byte 512 byte 512 byte
Subprocess images
Number of subprocess images, max. 15 15 15 15 15
Digital channels
• Inputs 128 000 128 000 128 000 128 000 128 000
•Outputs 128 000 128 000 128 000 128 000 128 000
Analog channels
• Inputs 8000 8 000 8 000 8000 8 000
•Outputs 8000 8 000 8 000 8000 8 000
Time of day
Clock
Hardware clock (real-time clock) Yes Yes;
Resolution: 1 s Yes Yes Yes
Clock synchronization
• supported Yes Yes Yes Yes Yes
•to PC-CP, slave Yes Yes Yes Yes Yes
on Ethernet via NTP Yes Yes Yes Yes Yes
Interfaces
Number of USB interfaces 2 2 2 2 2
serial interface 0 0 0 0 0
Industrial Ethernet
Industrial Ethernet interface X1: 2 ports
10/100 Mbit/s
(ERTEC-based)
X2: 1 port
10/100 Mbit/s
X1: 2 ports
10/100 Mbit/s
(ERTEC-based)
X2: 1 port
10/100 Mbit/s
X1: 2 ports
10/100 Mbit/s
(ERTEC-based)
X2: 1 port
10/100 Mbit/s
X1: 2 ports
10/100 Mbit/s
(ERTEC-based)
X2: 1 port
10/100 Mbit/s
X1: 2 ports
10/100 Mbit/s
(ERTEC-based)
X2: 1 port
10/100 Mbit/s
X1: 2 ports
10/100 Mbit/s
(ERTEC-based)
X2: 1 port
10/100 Mbit/s
6ES7677-1DD10-
0BA0 6ES7677-1DD10-
0BB0 6ES7677-1FD10-
0FB0 6ES7677-1DD10-
0BF0 6ES7677-1DD10-
0BG0 6ES7677-1DD10-
0BH0
SIMATIC
S7-mEC, EC31 S7-mEC,
EC31-RTX S7-mEC,
EC31-RTX F S7-mEC, EC31-
HMI/RTX 128PT S7-mEC, EC31-
HMI/RTX 512PT S7-mEC, EC31-
HMI/RTX 2048PT
ST80_2013_EN_Kap05.book Seite 95 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Embedded Controller
EC31
5/96 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
5
1st interface
Type of interface PROFINET PROFINET PROFINET PROFINET PROFINET
Physics 2x RJ45 2x RJ45 2x RJ45 2x RJ45 2x RJ45
Automatic detection of transmission
speed Yes Yes Yes Yes Yes
Autonegotiation Yes Yes Yes Yes Yes
Autocrossing Yes Yes Yes Yes Yes
Number of connection resources 32 32 32 32 32
Functionality
•MPI No
•DP master No
•DP slave No
PROFINET IO Device No No No No No
PROFINET IO Controller Yes Yes Yes Yes Yes
PROFINET CBA Yes Yes Yes Yes Yes
Point-to-point connection No
PROFINET IO Controller
Number of connectable IO devices,
max. 256 256 256 256 256
Max. number of connectable
IO devices for RT 256 256 256 256 256
- of which in line, max. 256 256 256 256 256
Number of IO devices with IRT
and the option "high flexibility" 256 256 256 256 256
- of which in line, max. 61 61 61 61 61
Number of IO Devices with IRT and
the option "high performance", max. 256 256 256 256 256
- of which in line, max. 64 64 64 64 64
• IRT, supported Yes Yes Yes Yes Yes
Prioritized startup supported Yes Yes Yes Yes Yes
- Number of IO Devices, max. 32 32 32 32 32
Activation/deactivation of IO Devices Yes Yes Yes Yes Yes
- Maximum number of IO devices
that can be activated/deactivated
at the same time.
8 8 8 8 8
IO Devices changing during opera-
tion (partner ports), supported Yes Yes Yes Yes Yes
- Max. number of IO devices
per tool 8 8 8 8 8
Device replacement without swap
medium Yes Yes Yes Yes Yes
Send cycles Adjustable:
250 µs, 500 µs
and 1 ms
Adjustable:
250 µs, 500 µs
and 1 ms
Adjustable:
250 µs, 500 µs
and 1 ms
Adjustable:
250 µs, 500 µs
and 1 ms
Adjustable:
250 µs, 500 µs
and 1 ms
• Updating times 250 µs - 128 ms
(with signal cycle
250 µs); 500 µs -
256 ms (with sig-
nal cycle 500 µs);
1 ms - 512 ms
(with signal cycle
1 ms)
250 µs - 128 ms
(with signal cycle
250 µs); 500 µs -
256 ms (with sig-
nal cycle 500 µs);
1 ms - 512 ms
(with signal cycle
1 ms)
250 µs - 128 ms
(with signal cycle
250 µs); 500 µs -
256 ms (with sig-
nal cycle 500 µs);
1 ms - 512 ms
(with signal cycle
1 ms)
250 µs - 128 ms
(with signal cycle
250 µs); 500 µs -
256 ms (with sig-
nal cycle 500 µs);
1 ms - 512 ms
(with signal cycle
1 ms)
250 µs - 128 ms
(with signal cycle
250 µs); 500 µs -
256 ms (with sig-
nal cycle 500 µs);
1 ms - 512 ms
(with signal cycle
1 ms)
• Services
- PG/OP communication Yes Yes Yes Yes Yes
-S7 routing Yes Yes Yes Yes Yes
- S7 communication Yes Yes Yes Yes Yes
- Isochronous mode Yes Yes Yes Yes Yes
Address area
- Inputs, max. 16 kbyte 16 kbyte 16 kbyte 16 kbyte 16 kbyte
-Outputs, max. 16 kbyte 16 kbyte 16 kbyte 16 kbyte 16 kbyte
- User data per address area, max. 2kbyte 2kbyte 2kbyte 2kbyte 2kbyte
- User data consistency, max. 256 byte 256 byte 256 byte 256 byte 256 byte
6ES7677-1DD10-
0BA0 6ES7677-1DD10-
0BB0 6ES7677-1FD10-
0FB0 6ES7677-1DD10-
0BF0 6ES7677-1DD10-
0BG0 6ES7677-1DD10-
0BH0
SIMATIC
S7-mEC, EC31 S7-mEC,
EC31-RTX S7-mEC,
EC31-RTX F S7-mEC, EC31-
HMI/RTX 128PT S7-mEC, EC31-
HMI/RTX 512PT S7-mEC, EC31-
HMI/RTX 2048PT
ST80_2013_EN_Kap05.book Seite 96 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Embedded Controller
EC31
5/97
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
Open IE communication
• Open IE communication, supported Yes Yes Yes Yes Yes
Number of connections, max. 32 32 32 32 32
Local port numbers used
at the system end 0, 20, 21, 23, 25,
80, 102, 135,
161, 8080,
34962, 34963,
34964, 65532,
65533, 65534,
65535
0, 20, 21, 23, 25,
80, 102, 135,
161, 8080,
34962, 34963,
34964, 65532,
65533, 65534,
65535
0, 20, 21, 23, 25,
80, 102, 135,
161, 8080,
34962, 34963,
34964, 65532,
65533, 65534,
65535
0, 20, 21, 23, 25,
80, 102, 135,
161, 8080,
34962, 34963,
34964, 65532,
65533, 65534,
65535
0, 20, 21, 23, 25,
80, 102, 135,
161, 8080,
34962, 34963,
34964, 65532,
65533, 65534,
65535
PROFINET functions
Detection of accessible nodes,
supported Yes; DCP Yes; DCP Yes; DCP Yes; DCP Yes; DCP
Assignment of the IP address,
supported Yes; DCP Yes; DCP Yes; DCP Yes; DCP Yes; DCP
Assignment of the device name,
supported Yes; DCP Yes; DCP Yes; DCP Yes; DCP Yes; DCP
Topology recognition, supported Yes; LLDP, LLDP
MIB, SNMP Yes; LLDP, LLDP
MIB, SNMP Yes; LLDP, LLDP
MIB, SNMP Yes; LLDP, LLDP
MIB, SNMP Yes; LLDP, LLDP
MIB, SNMP
• Extended network diagnostics
with Standard MIB II, supported Yes; Standard
MIB II, SNMP Yes; Standard
MIB II, SNMP Yes; Standard
MIB II, SNMP Yes; Standard
MIB II, SNMP Yes; Standard
MIB II, SNMP
2nd interface
Type of interface Integrated Ether-
net interface Integrated Ether-
net interface Integrated Ether-
net interface Integrated Ether-
net interface Integrated Ether-
net interface
Physics Ethernet RJ45 Ethernet RJ45 Ethernet RJ45 Ethernet RJ45 Ethernet RJ45
Automatic detection of transmission
speed Yes Yes Yes Yes Yes
Autonegotiation Yes Yes Yes Yes Yes
Autocrossing No No No No No
Number of connection resources 32 32 32 32 32
Functionality
PROFINET IO Controller No No No No No
PROFINET IO Device No No No No No
PROFINET CBA No No No No No
PROFINET functions
Detection of accessible nodes,
supported Yes; DCP Yes; DCP Yes; DCP Yes; DCP Yes; DCP
Assignment of the IP address,
supported Yes; DCP Yes; DCP Yes; DCP Yes; DCP Yes; DCP
Assignment of the device name,
supported Yes; DCP Yes; DCP Yes; DCP Yes; DCP Yes; DCP
Topology recognition, supported Yes; LLDP, LLDP
MIB, SNMP Yes; LLDP, LLDP
MIB, SNMP Yes; LLDP, LLDP
MIB, SNMP Yes; LLDP, LLDP
MIB, SNMP Yes; LLDP, LLDP
MIB, SNMP
• Extended network diagnostics
with Standard MIB II, supported Yes; Standard
MIB II, SNMP Yes; Standard
MIB II, SNMP Yes; Standard
MIB II, SNMP Yes; Standard
MIB II, SNMP Yes; Standard
MIB II, SNMP
Communication functions
PG/OP communication Yes Yes Yes Yes Yes
Global data communication
• supported No No No No No
S7 basic communication
• supported No No No No No
S7 communication
• supported Yes Yes Yes Yes Yes
•as server Yes Yes Yes Yes Yes
as client Yes Yes Yes Yes Yes
6ES7677-1DD10-
0BA0 6ES7677-1DD10-
0BB0 6ES7677-1FD10-
0FB0 6ES7677-1DD10-
0BF0 6ES7677-1DD10-
0BG0 6ES7677-1DD10-
0BH0
SIMATIC
S7-mEC, EC31 S7-mEC,
EC31-RTX S7-mEC,
EC31-RTX F S7-mEC, EC31-
HMI/RTX 128PT S7-mEC, EC31-
HMI/RTX 512PT S7-mEC, EC31-
HMI/RTX 2048PT
ST80_2013_EN_Kap05.book Seite 97 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Embedded Controller
EC31
5/98 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
5
Open IE communication
•TCP/IP Yes;
Via integrated
PROFINET inter-
face (X1) and
loadable FBs
Yes;
Via integrated
PROFINET inter-
face (X1) and
loadable FBs
Yes;
Via integrated
PROFINET inter-
face (X1) and
loadable FBs
Yes;
Via integrated
PROFINET inter-
face (X1) and
loadable FBs
Yes;
Via integrated
PROFINET inter-
face (X1) and
loadable FBs
- Number of connections, max. 32 32 32 32 32
- Data length, max. 32 kbyte 32 kbyte 32 kbyte 32 kbyte 32 kbyte
• ISO-on-TCP (RFC1006) Yes;
Via integrated
PROFINET inter-
face (X1) and
loadable FBs
Yes;
via integrated
PROFINET inter-
face and load-
able FBs
Yes;
Via integrated
PROFINET inter-
face (X1) and
loadable FBs
Yes;
Via integrated
PROFINET inter-
face (X1) and
loadable FBs
Yes;
Via integrated
PROFINET inter-
face (X1) and
loadable FBs
- Number of connections, max. 32 32 32 32 32
- Data length, max. 32 kbyte 32 kbyte 32 kbyte 32 kbyte 32 kbyte
• UDP Yes;
Via integrated
PROFINET inter-
face (X1) and
loadable FBs
Yes;
Via integrated
PROFINET inter-
face (X1) and
loadable FBs
Yes;
Via integrated
PROFINET inter-
face (X1) and
loadable FBs
Yes;
Via integrated
PROFINET inter-
face (X1) and
loadable FBs
Yes;
Via integrated
PROFINET inter-
face (X1) and
loadable FBs
- Number of connections, max. 32 32 32 32 32
- Data length, max. 1472byte 1 472 byte 1 472 byte 1472byte 1 472 byte
S7 message functions
Number of login stations for message
functions, max. 62; The alarm
functions cannot
currently be used
for central bus
modules
62; The alarm
functions cannot
currently be used
for central bus
modules
62; The alarm
functions cannot
currently be used
for central bus
modules
62; The alarm
functions cannot
currently be used
for central bus
modules
62; The alarm
functions cannot
currently be used
for central bus
modules
Process diagnostic messages Yes; Alarm_S Yes; Alarm_S Yes; Alarm_S Yes; Alarm_S Yes; Alarm_S
Test commissioning functions
Status/control
Status/control variable Yes Yes Yes Yes Yes
Forcing
• Forcing No No No No No
Diagnostic buffer
•present Yes Yes Yes Yes Yes
Ambient conditions
Operating temperature
•Min. C 0°C 0°C 0°C 0°C 0°C
•max. 50 °C 50 °C 50 °C 50 °C 50 °C 50 °C
Configuration
programming
• Programming language
-LAD Yes Yes Yes Yes Yes
-FBD Yes Yes Yes Yes Yes
-STL Yes Yes Yes Yes Yes
-SCL Yes Yes Yes Yes Yes
-CFC Yes Yes Yes Yes Yes
- GRAPH Yes Yes Yes Yes Yes
-HiGraph® Yes Yes Yes Yes Yes
Dimensions
Width 160 mm 160 mm 160 mm 160 mm 160 mm 160 mm
Height 125 mm 125 mm 125 mm 125 mm 125 mm 125 mm
Depth 115 mm 115 mm 115 mm 115 mm 115 mm 115 mm
Weight
Weight, approx. 1.5 kg 1.5 kg 1.5 kg 1.5 kg 1.5 kg 1.5 kg
6ES7677-1DD10-
0BA0 6ES7677-1DD10-
0BB0 6ES7677-1FD10-
0FB0 6ES7677-1DD10-
0BF0 6ES7677-1DD10-
0BG0 6ES7677-1DD10-
0BH0
SIMATIC
S7-mEC, EC31 S7-mEC,
EC31-RTX S7-mEC,
EC31-RTX F S7-mEC, EC31-
HMI/RTX 128PT S7-mEC, EC31-
HMI/RTX 512PT S7-mEC, EC31-
HMI/RTX 2048PT
ST80_2013_EN_Kap05.book Seite 98 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Embedded Controller
EC31
5/99
Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
SIMATIC S7-modular
Embedded Controller
EC31 6ES7677-1DD10-0BA0
Intel CoreDuo 1.2 GHz processor
Memory configuration:
1 GB RAM, 4 GB Flash Disk;
interfaces:
1 Industrial Ethernet port,
2 PROFINET ports, 2 USB ports,
1 slot for multimedia card;
Software:
Windows Embedded Standard pre-
installed, Software Development Kit
(SDK) for creating C/C++ applica-
tions with accesses to central
I/O modules
EC31-RTX 6ES7677-1DD10-0BB0
Intel CoreDuo 1.2 GHz processor
Memory configuration:
1 GB RAM, 4 GB Flash Disk;
interfaces:
1 Industrial Ethernet port,
2 PROFINET ports, 2 USB ports,
1 slot for multimedia card;
Software:
Windows Embedded Standard and
WinAC RTX 2010 preinstalled
EC31-RTX F 6ES7677-1FD10-0FB0
Intel CoreDuo 1.2 GHz processor
Memory configuration:
1 GB RAM, 4 GB Flash Disk;
interfaces:
1 Industrial Ethernet port,
2 PROFINET ports, 2 USB ports,
1 slot for multimedia card;
Software:
Windows Embedded Standard and
WinAC RTX F 2010 preinstalled
EC31-HMI/RTX
Intel CoreDuo 1.2 GHz processor
Memory configuration:
1 GB RAM, 4 GB Flash Disk;
interfaces:
1 Industrial Ethernet port,
2 PROFINET ports, 2 USB ports,
1 slot for multimedia card;
Software:
Windows Embedded Standard,
WinAC RTX 2010, SIMATIC
SOFTNET-S7/V7.0 Lean preinstalled
With WinCC flexible 2008 RT
128 PT 6ES7677-1DD10-0BF0
With WinCC flexible 2008 RT
512 PT 6ES7677-1DD10-0BG0
With WinCC flexible 2008 RT
2048 PT 6ES7677-1DD10-0BH0
Accessories
EM PCI-104 expansion module 6ES7677-1DD60-1AA0
For fitting up to 3 additional
PCI-104 cards
EM PC expansion module 6ES7677-1DD50-2AA0
Additional connection options:
2 USB interfaces, 1 Gigabit Ethernet
interface, 1 serial interface, 1 slot for
CF card, 1 slot for SD card/Micro
Memory Card
ST80_2013_EN_Kap05.book Seite 99 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Embedded Controller
Expansion modules
5/100 Siemens ST 80 / ST PC · 2013
5
Overview
Expansion modules for SIMATIC S7-modular Embedded
Controller EC31
- EM PCI-104 for additionally accommodating up to
3 PCI-104 cards
- EM PC with additional PC interfaces and slots for memory
media
Technical specifications
Ordering data
Order No.
6ES7677-
1DD60-1AA0 6ES7677-
1DD50-2AA0
EM PCI-104 EM PC
General information
Hardware product version 01 01
Input current
from expansion bus 100 mA 580 mA
Power losses
Power loss, typ. 2.4 W; Without
inserted PCI-104
cards
9W
Power loss, max. 14 W
Interfaces
Number of USB interfaces 0 2
serial interface 01x V.24 (RS232)
Industrial Ethernet
• Industrial Ethernet interface Onboard, 10/
100/1000 Mbit,
RJ45
Ambient conditions
Operating temperature
•Min. C 0°C
•max. 50 °C 50 °C
Dimensions
Width 120 mm; With-
out bus connec-
tor Extension-
Bus
80 mm; Without
bus connector
Extension-Bus
Height 125 mm; With-
out external volt-
age connecting
terminal
125 mm
Depth 115 mm 115 mm
Weight
Weight, approx. 0.5 kg 0.4 kg
EM PCI-104 expansion module 6ES7677-1DD60-1AA0
For fitting up to 3 additional
PCI-104 cards
EM PC expansion module 6ES7677-1DD50-2AA0
Additional connection options:
1 DVI-I interface, 2 USB interfaces,
1 Gigabit Ethernet interface, 1 serial
interface, 1 slot for CF card, 1 slot
for SD card/Micro Memory Card
ST80_2013_EN_Kap05.book Seite 100 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Embedded bundles/Software packages
Embedded bundles/Software packages
5/101
Siemens ST 80 / ST PC · 2013
Overview
The Embedded Bundles for PC-based Automation are based on
rugged, fan-free SIMATIC IPCs. They are pre-installed,
configured, and ready-to-use with the SIMATIC WinAC RTX (F)
software controller and/or the SIMATIC WinCC/WinCC flexible
visualization software.
Software packages with WinCC or WinAC together with the
corresponding SIMATIC IPC.
The following are available:
SIMATIC IPC packages with WinCC flexible
SIMATIC IPC packages with WinCC RT Advanced
(TIA Portal)
SIMATIC IPC Packages with WinCC
SIMATIC IPC packages with WinCC RT Professional
(TIA Portal)
SIMATIC IPC packages with WinAC RTX (F)
A Software Package can only be supplied if the same number
of SIMATIC industrial PCs is ordered together with the software.
It cannot be ordered subsequently.
More information
You can find more information on the Internet at:
http://www.automation.siemens.com/mcms/pc-based-
automation/en/embedded-bundles
ST80_2013_EN_Kap05.book Seite 101 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Embedded bundles/Software packages
SIMATIC IPC227D bundles
5/102 Siemens ST 80 / ST PC · 2013
5
Overview
A quick start in automation solutions with embedded PC
platforms
- SIMATIC WinAC RTX or SIMATIC WinAC RTX F preinstalled
on SIMATIC IPC227D and ready for use
- PROFINET RT and Industrial Ethernet pre-configured for use
in a SIMATIC environment
- Optional WinCC RT Advanced for visualization tasks in
parallel with SIMATIC WinAC RTX
- Configuration and programming with SIMATIC STEP 7 via
Industrial Ethernet or PROFINET
Safety requirements up to SIL 3 in accordance with
IEC 61508/62061 or EN ISO 13849-1 up to PL e can be
implemented with WinAC RTX F.
Rugged operation
- Hard-disk-free operation with CompactFlash card (CF card)
or solid-state drive and Windows Embedded Standard 2009
or Windows Embedded Standard 7, 32-bit
- Fan-free operation
- 128 KB of retentive data for WinAC RTX,
also without uninterruptible power supply (UPS)
Flexibility of a PC-based automation environment
- Use of WinAC ODK with SIMATIC WinAC RTX or
SIMATIC WinAC RTX F (read-only for fail-safe program
section)
- Connection option for USB devices, flat panel monitor or
screen
- PCIe cards can be plugged in
Technical specifications
See "PC-based Automation -> Box PC -> SIMATIC IPC227D".
Ordering data
For Selection and ordering data see
SIMATIC Box PC -> SIMATIC IPC227D
More information
Delivery
Production and delivery of the devices will typically be
completed within 15 business days after receipt of order. The
hardware and mass memory with the complete, pre-installed,
ready-to-use software are supplied fully assembled.
ST80_2013_EN_Kap05.book Seite 102 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Embedded bundles/Software packages
SIMATIC IPC427D bundles
5/103
Siemens ST 80 / ST PC · 2013
Overview
SIMATIC IPC427D (Microbox PC):
The powerful embedded IPC – maintenance-free
with versatile configuration
Ready-to-run, complete solutions (software is already installed
and preconfigured) for visualization and automation in
connection with WinCC RT Advanced and/or WinAC RTX.
Ultra-compact
Maintenance-free
Third generation Intel Core i technology
Current product versions of the pre-installed software:
- SIMATIC WinCC RT Advanced V12
- SIMATIC WinAC RTX 2010
- SIMATIC Net V8.x
Technical specifications
See "PC-based Automation -> Box PC -> SIMATIC IPC427D"
Ordering data
For selection and ordering data, see "SIMATIC Box PC ->
SIMATIC IPC427D"
More information
Delivery
Production and delivery of the devices will typically be
completed within 13 business days after receipt of order. The
hardware and mass memory with the complete, pre-installed,
ready-to-use software are supplied fully assembled.
Commissioning
Before the control or visualization application is complete,
simply perform the following steps:
Optional: Installation and setup of additional software on the
device
Optional: Installation and setup of other software on the device
Transfer of the engineering projects from STEP 7 or
WinCC Advanced
Transfer of the supplied license keys for SIMATIC software
Backup of the installed software and protection of the flash-
based mass memory by switching on the Enhance Write filter
ST80_2013_EN_Kap05.book Seite 103 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Embedded bundles/Software packages
SIMATIC IPC427C bundles
5/104 Siemens ST 80 / ST PC · 2013
5
Overview
Embedded PC platform with extremely high industrial compati-
bility for demanding tasks in the field of PC-based automation
Rugged operation
- Operation without a hard disk, based on CompactFlash card
(CF Card) or solid-state drive and Windows Embedded
Standard
- Fan-free operation
- 128 KB of retentive data for WinAC RTX,
also without uninterruptible power supply (UPS)
Flexibility of a PC-based automation environment
- Free memory space on CF Card can be used for other
PC applications
- Use of WinAC ODK with SIMATIC WinAC RTX or
SIMATIC WinAC RTX F (read-only for fail-safe program
section)
- Connection option for USB devices, flat panel monitor or
screen
- PCI 104 cards can be plugged in
High-performance service concept
- Replacement parts for preferred types available ex stock
Safety requirements up to SIL 3 in accordance with
IEC 61508/62061 or EN ISO 13849-1 up to PL e can be
implemented with WinAC RTX F.
Cost-effective versions with PROFINET, based on the
standard Ethernet interface
Current product versions of the pre-installed software:
- SIMATIC WinAC RTX 2010 or SIMATIC WinAC RTX F 2010
- SIMATIC WinCC flexible 2008 or WinCC RT Advanced
- and the combinations of the software packages above
- SIMATIC NET Edition 2008 or V8.1 (depending on operating
system), as well as
- SIMATIC WInCC V7.0 SP2 or WinCC RT Professional as a
client / single station
ST80_2013_EN_Kap05.book Seite 104 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Embedded bundles/Software packages
SIMATIC IPC427C bundles
5/105
Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
1)
Replacement hardware units available in exchange
2)
Only together from 2 GB main memory
3)
WinCC flexible 2008 SP2 with WES2009 and
WinCC flexible 2008 SP3 with WES7
SIMATIC IPC427C bundles
RTX bundles with
SIMATIC WinAC RTX (F) 2010
HMI bundles with
WinCC flexible 2008 or
WinCC RT Advanced V11 bundles
HMI/RTX bundles
combining HMI and RTX
SIMATIC IPC427C
with pre-installed software 6ES7675-1D
777
-
7777
Processor
Celeron M, 1.2 GHz,
2x PROFINET (IE)
1)
A
Celeron M, 1.2 GHz,
2x PROFINET (IE), 1x PROFIBUS
1)
B
• Core2 Solo, 1.2 GHz,
2x PROFINET (IE)
1)
E
• Core2 Solo, 1.2 GHz,
2x PROFINET (IE), 1x PROFIBUS
1)
F
• Core2 Solo, 1.2 GHz,
1x PROFINET (IE),
PROFINET (RT/IRT) 3 ports
G
Core2 Duo, 1.2 GHz,
2x PROFINET (IE)
1)
J
Core2 Duo, 1.2 GHz,
• 2x PROFINET (IE),
1x PROFIBUS
1)
K
Core2 Duo, 1.2 GHz, 1x PROFINET
(IE), PROFINET (RT/IRT) 3 ports L
Main memory
•1 GB RAM 2
•2 GB RAM
1)
3
•4 GB RAM 4
Operating system
• Windows Embedded Standard
2009 (WES2009)
1)
0
• Windows Embedded Standard 7
(WES7)
2)
1
Mass storage, internal
None (can only be ordered
with externally accessible mass
storage)
1)
0
• 250 GB HDD SATA, only addition-
ally with externally accessible CF 1
50 GB solid-state drive
(high-endurance), operating
system and software pre-installed
2
80 GB solid-state drive
(standard SATA), operating system
and software pre-installed
3
4 GB internal CompactFlash,
operating system and software
pre-installed
1)
6
8 GB internal CompactFlash,
operating system and software
pre-installed
1)
7
16 GB internal CompactFlash,
operating system and software
pre-installed
1)
8
SIMATIC IPC427C
with pre-installed software
(continued)
6ES7675-1D
7 7 7
-
7777
Externally accessible mass storage
• None (can only be ordered
with internal mass storage)
1)
A
• 4 GB CompactFlash,
operating system and
software pre-installed
1)
D
• 8 GB CompactFlash,
operating system and
software pre-installed
1)
E
• 16 GB internal CompactFlash,
operating system and software
pre-installed
1)
F
Software configurations
1)
•WinAC RTX B
• HMI RT 128 PT C
• HMI RT 512 PT D
• HMI RT 2048 PT E
• HMI RT 4096 PT F
• WinAC RTX, HMI RT 128 PT K
• WinAC RTX, HMI RT 512 PT L
• WinAC RTX, HMI RT 2048 PT M
• WinAC RTX, HMI RT 4096 PT N
•WinAC RTX F P
• WinAC RTX F, HMI RT 128 PT R
• WinAC RTX F, HMI RT 512 PT S
• WinAC RTX F, HMI RT 2048 PT T
• WinAC RTX F, HMI RT 4096 PT U
• HMI RT: WinCC flexible 2008
3)
or w/o HMI software 0
• HMI RT: WinCC Advanced V11
SP2 (TIA Portal), only with WES7
and 2GB RAM
1
ST80_2013_EN_Kap05.book Seite 105 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Embedded bundles/Software packages
SIMATIC IPC427C bundles
5/106 Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
5
1)
Number of process tags (PT) can be increased by means of PowerPacks.
In-stock models
Replacement hardware units
available in exchange
SIMATIC IPC427C bundle with
WinAC RTX 2010
• Core2 Solo processor, 1.2 GHz,
2x PROFINET (IE), 1x PROFIBUS,
2 GB RAM, 4 GB CompactFlash
6ES7675-1DF30-0DB0
• Core2 Duo processor, 1.2 GHz,
2x PROFINET (IE), 1x PROFIBUS,
2 GB RAM, 4 GB CompactFlash
6ES7675-1DK30-0DB0
• Core2 Duo processor, 1.2 GHz,
2x PROFINET (IE), 1x PROFIBUS,
2 GB RAM, 8 GB CompactFlash
6ES7675-1DK30-0EP0
SIMATIC IPC427C bundle
with WinAC RTX 2010 and
WinCC flexible 2008 512 PT
• Core2 Duo processor, 1.2 GHz,
2x PROFINET (IE), 1x PROFIBUS,
2 GB RAM, 4 GB CompactFlash
6ES7675-1DK30-0DL0
Bundles with WinCC
("Built to order" with max. delivery
time of 14 working days; only repairs
are possible for hardware)
IPC427C with WinCC RT, V7.0
SP2, incl. Update 1
Fan-free, 4 x USB 2.0 (500 mA),
1 x COM (RS 232),
24 V DC power supply
with On/Off switch,
2 x PROFINET (IE),
Windows Embedded Standard 2009
pre-installed,
SIMATIC WinCC V7.0 SP2 incl.
Update1 Runtime pre-installed
Client configurations 6ES7675-1DA20-6AX0
Processor Celeron M 1.2 GHz,
1 GB SDRAM-DDR3,
4 GB CF Card,
runtime license 128 PT
Client and stand-alone station
configurations
Core2 Solo processor 1.2 GHz,
8 GB CF card,
runtime license 128 PT
1)
6ES7675-1DE30-7AX0
Core2 Solo processor 1.2 GHz,
PROFIBUS DP,
2 GB SDRAM-DDR3,
8 GB CF card,
runtime license 128 PT
1)
6ES7675-1DF30-7AX0
Stand-alone station
configurations 6ES7675-1DK40-.A.0
Core2 Duo processor 1.2 GHz,
PROFIBUS DP, 4 GB SDRAM-DDR3
8 GB CF card,
runtime license 128 PT
1)
6ES7675-1DK40-7AX0
50 GB SSD (High Endurance),
runtime license 128 PT
1)
6ES7675-1DK40-2AX0
8 GB CF card,
runtime license 2048 PT
1)
6ES7675-1DK40-7AW0
50 GB SSD (High Endurance),
runtime license 2048 PT
1)
6ES7675-1DK40-2AW0
Bundles with WinCC RT
Professional (TIA Portal)
("Built to order" with max. delivery
time of 14 working days; only repairs
are possible for hardware)
IPC427C with WinCC RT
Professional, V11 SP2
Fan-free, 4 x USB 2.0 (500 mA),
1 x COM (RS 232),
24 V DC power supply
with On/Off switch,
2 x PROFINET (IE),
Windows Embedded Standard 7
SP1 pre-installed,
SIMATIC WinCC Runtime
Professional V11 SP2 pre-installed
Client configurations 6ES7675-1DA31-7AY0
• Celeron M processor 1.2 GHz,
2 GB SDRAM DDR3,
8 GB CF card,
runtime license 128 PT
1)
Client and stand-alone station
configurations
• Core2 Solo processor 1.2 GHz,
2 GB SDRAM DDR3,
8 GB CF card,
runtime license 128 PT
1)
6ES7675-1DE31-7AY0
• Core2 Solo processor 1.2 GHz,
PROFIBUS DP,
2 GB SDRAM DDR3,
8 GB CF card,
runtime license 128 PT
1)
6ES7675-1DF31-7AY0
Stand-alone station
configurations
Core2 Duo processor 1.2 GHz,
PROFIBUS DP, 4 GB SDRAM-DDR3
• 8 GB CF card,
runtime license 128 PT
1)
6ES7675-1DK41-7AY0
• 50 GB SSD (High Endurance),
runtime license 128 PT
1)
6ES7675-1DK41-2AY0
• 8 GB CF card,
runtime license 2048 PT
1)
6ES7675-1DK41-7AV0
• 50 GB SSD (High Endurance),
runtime license 2048 PT
1)
6ES7675-1DK41-2AV0
Accessories
CP 5603 Microbox Package 6GK1560-3AU00
Package for using the PROFIBUS
CP 5603 in Microbox PCs;
comprising a CP 5603 module and
a Microbox expansion rack
CP 1604 Microbox Package 6GK1160-4AU00
Package for the use of the
PROFINET CP 1604
in Microbox PCs;
consisting of CP 1604 card,
connection board, power supply
and Microbox PC expansion frame;
used via development kit
DK-16xx PN IO; NCM P
Portrait assembly kit 6ES7648-1AA20-0YB0
Interfaces to the front
Expansion components From page 5/153
ST80_2013_EN_Kap05.book Seite 106 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Embedded bundles/Software packages
SIMATIC IPC427C bundles
5/107
Siemens ST 80 / ST PC · 2013
More information
Delivery
Production and delivery of the devices will typically be
completed within 13 business days after receipt of order. The
hardware and mass memory with the complete, pre-installed,
ready-to-use software are supplied fully assembled.
Commissioning
Before the control or visualization application is complete,
simply perform the following steps:
Optional: Install and setup additional hardware on the device
(e.g. an additional SIMATIC CP 5603 PROFIBUS interface)
Optional: Installation and setup of other software on the device
Transfer of the engineering projects from STEP 7 and/or
WinCC flexible
Transfer of the supplied license keys for SIMATIC software
Backup of the installed software and protection of the flash-
based mass memory by switching on the Enhance Write filter
Replacement units
For the preferred versions, repaired replacement devices are
available extremely quickly ex stock. Preferred versions offer the
following options:
All processor versions with PROFINET(IE) or PROFIBUS
option
•2 GB RAM
Exclusively for replaceable CompactFlash memory
(supplied without mass memory)
All software configurations
ST80_2013_EN_Kap05.book Seite 107 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Embedded bundles/Software packages
SIMATIC IPC277D bundles
5/108 Siemens ST 80 / ST PC · 2013
5
Overview
SIMATIC IPC277D for implementing simple visualization and
control tasks
High degree of flexibility when selecting rugged widescreen
fronts from 7" to 19" for more freely configurable display area
High resolution, large viewing angle and up to 100%
dimmable backlighting for brilliant display with optimized
power consumption
Absolutely maintenance-free due to the use of CompactFlash
and SSD as mass storage and fanless operation up to 50 °C
ambient temperature
Maximum industrial functionality due to non-volatile retentive
memory for battery-free operation
Ready-to-run embedded bundles with visualization or/and
control software
The following front installation versions are available:
•7" Touch
•9" Touch
12" Touch
15" Touch with front USB interface
19" Touch with front USB interface
All fronts in widescreen design
Technical specifications
See "PC-based Automation -> Panel PC -> SIMATIC IPC277D"
Ordering data
For selection and ordering data see
SIMATIC Panel PC -> SIMATIC IPC277D
More information
Delivery
Production and delivery of the devices will typically be
completed within 13 business days after receipt of order. The
hardware and mass memory with the complete, pre-installed,
ready-to-use software are supplied fully assembled.
ST80_2013_EN_Kap05.book Seite 108 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Embedded bundles/Software packages
SIMATIC IPC477D bundles
5/109
Siemens ST 80 / ST PC · 2013
Overview
SIMATIC IPC477D:
The powerful embedded Panel PC –
maintenance-free with versatile configuration
Ready-to-run, complete solutions (software is already installed
and preconfigured) for visualization and automation in
connection with WinCC RT Advanced and/or WinAC RTX.
Embedded PC platform with extremely high industrial compat-
ibility for demanding tasks in the field of PC-based automation
Maintenance-free (no rotating components such as fan and
hard disk)
Rugged construction: the PC is resistant to even the harshest
mechanical stress and is extremely reliable in operation
Compact design
Battery-independent retentive memory onboard
High investment protection
Fast integration capability
Safety requirements up to SIL 3 in accordance with
IEC 61508/62061 or EN ISO 13849-1 up to PL e can be
implemented with WinAC RTX F
The following front versions are available:
Built-in versions
- 12" TFT Touch
- 15" TFT Touch
- 19" TFT Touch
- 22" TFT Touch
- 15" TFT Touch/Key
Current product versions of the pre-installed SIMATIC
software:
- SIMATIC WinCC RT Advanced V12
- SIMATIC WinAC RTX 2010 or SIMATIC WinAC RTX F 2010
- SIMATIC NET V8.2 (including SIMATIC SOFTNET S7 Basis
license)
- and the combinations of the software packageslisted above
Integration
Integrated interfaces:
• Ethernet
The integral PROFINET interfaces (10/100/1000 Mbit/s) can
be used for IT communication and for data exchange with
programmable controllers such as SIMATIC S7
(with software packages "SOFTNET S7 Basis").
PROFIBUS onboard (option)
The isolated PROFIBUS interface (12 Mbit/s) can be used
for connecting distributed field devices or for coupling to
SIMATIC S7 (with software packages "SOFTNET for
PROFIBUS").
Other interfaces
5 USB (Universal Serial Bus) interfaces and up to two serial
interfaces are available for connecting additional I/O devices.
Technical specifications
See "PC-based Automation -> Panel PC -> SIMATIC IPC477D"
Ordering data
For selection and ordering data,
see SIMATIC Panel PC -> SIMATIC IPC477D
ST80_2013_EN_Kap05.book Seite 109 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Embedded bundles/Software packages
SIMATIC HMI IPC477C bundles
5/110 Siemens ST 80 / ST PC · 2013
5
Overview
Embedded PC platform with extremely high industrial compati-
bility for demanding tasks in the field of PC-based automation.
Rugged operation
- Operation without a hard disk, based on CompactFlash card
(CF Card) or solid-state drive and Windows Embedded
Standard
- Fan-free operation
- 128 KB of retentive data for WinAC RTX, also without
uninterruptible power supply (UPS)
Flexibility of a PC-based automation environment
- Free memory space on CF Card can be used for other PC
applications
- Use of WinAC ODK with SIMATIC WinAC RTX or SIMATIC
WinAC RTX F (read-only for fail-safe program section)
- Connection option for USB devices, flat panel monitor or
screen
High-performance service concept
- Replacement parts for preferred types available ex stock
Safety requirements up to SIL 3 in accordance with
IEC 61508/62061 or EN ISO 13849-1 up to PL e can be
implemented with WinAC RTX F.
Cost-effective versions with PROFINET, based on the
standard Ethernet interface
Product versions of the pre-installed software:
- SIMATIC WinAC RTX 2010 or SIMATIC WinAC RTX F 2010
- SIMATIC WinCC flexible 2008 or WinCC RT Advanced
- and the combinations of the software packages above
- SIMATIC NET Edition 2008 or V8.x (depending on operating
system) as well as
- SIMATIC WInCC V7.0 SP2 or WinCC RT Professional as a
client / single station
The following display versions are available:
Built-in versions
- 12" and 15" TFT Touch
- 12" and 15" TFT Key
- 19" Touch
Support arm versions
- PRO 15" and 19" Touch
Fully-enclosed device to IP65 degree of protection for
mounting on a support arm/stand.
ST80_2013_EN_Kap05.book Seite 110 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Embedded bundles/Software packages
SIMATIC HMI IPC477C bundles
5/111
Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
SIMATIC HMI IPC477C bundles
RTX bundles with
SIMATIC WinAC RTX (F) 2010
HMI bundles with
WinCC flexible 2008 or
WinCC RT Advanced bundles
HMI/RTX bundles
combining HMI and RTX
("Built to order" version, max. deli-
very time of 15 working days and
with identified repair, if not preferred
type)
SIMATIC HMI IPC477C PRO 6AV7883-
7
A
7 7 7
-
7 7 7 7
Embedded and fan-free
with fully enclosed IP65 enclosure
4 x USB (500 mA),
24 V DC power supply
with On/Off switch
SIMATIC HMI IPC477C 6AV7884-
7
A
7 7 7
-
7 7 7 7
Fan-free
5 x USB 2.0 (500 mA),
one of which on the front
1 x COM (RS232)
24 V DC power supply
with On/Off switch
Front panels
12" TFT Touch
1)
0
12" TFT Key 1
15" TFT Touch
1)
2
15" TFT Key 3
19" TFT Touch
1)
5
15" TFT Touch
(IP65 enclosure; PRO) 6
19" TFT Touch
(IP65 enclosure; PRO) 7
1)
Preferred versions with repaired replacement device from warehouse
2)
Only together from 2 GB main memory
3)
Only with IPC477C
SIMATIC HMI IPC477C
(continued) 6AV7884-
7
A
777
-
7 7 7 7
Processors and fieldbus
• Celeron M 1.2 GHz,
2 x PROFINET (IE)
1)
A
• Celeron M 1.2 GHz,
2 x PROFINET (IE),
1 x PROFIBUS DP 12
1)
B
• Core2 Solo 1.2 GHz,
2 x PROFINET (IE)
1)
D
• Core2 Solo 1.2 GHz,
2 x PROFINET (IE),
1 x PROFIBUS DP 12
1)
E
• Core2 Solo 1.2 GHz,
1 x PROFINET (IE),
1 x PROFINET (3 ports)
1)
F
• Core2 Duo 1.2 GHz,
2 x PROFINET (IE)
1)
G
• Core2 Duo 1.2 GHz,
2 x PROFINET (IE),
1 x PROFIBUS DP 12
1)
H
• Core2 Duo 1.2 GHz,
1 x PROFINET (IE),
1 x PROFINET (3 ports)
1)
J
Main memory (DDR3 RAM),
1 database
•1 GB 1
•2 GB
1)
2
•4 GB 3
Second mass storage
(installed, CF replaceable)
• None
1)
0
• CompactFlash 2 GB
(only with Windows Embedded
Standard 2009)
1)
2
• CompactFlash 4 GB
1)
3
• CompactFlash 8 GB
1)
4
• CompactFlash 16 GB
1)
5
• 50 GB SSD (High Endurance) 6
• 80 GB SSD (Standard)
3)
7
ST80_2013_EN_Kap05.book Seite 111 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Embedded bundles/Software packages
SIMATIC HMI IPC477C bundles
5/112 Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
5
1)
Preferred versions with repaired replacement device from warehouse
2)
Only together from 2 GB main memory
3)
Only with IPC477C
4)
with WES 2009: SP2; with WES 7: SP3
SIMATIC HMI IPC477C
(continued) 6AV7884-
7
A
7 7 7
-
7777
Mass storage
(installed, operating system
pre-installed, optionally with
SIMATIC software)
• CompactFlash 2 GB
1)
2
• CompactFlash 4 GB
1)
3
• CompactFlash 8 GB
1)
4
• CompactFlash 16 GB
1)
5
50 GB SSD (High Endurance) 6
80 GB SSD (Standard)
3)
7
Operating system
• Windows Embedded Standard
2009, pre-installed
1)
B A
• Windows Embedded Standard 7
SP1, pre-installed
2)
E A
Software packages,
only with CF 4 GB or higher
1)
• with operating system and RTX
pre-installed and configured B
• with operating system and HMI
(incl. archives/recipes)
pre-installed and configured
- Number of tags 128 PT C
- Number of tags 512 PT D
- Number of tags 2048 PT E
- Number of tags 4096 PT F
• with operating system and
HMI/RTX (incl. archives/recipes)
pre-installed and configured
- Number of tags 128 PT K
- Number of tags 512 PT L
- Number of tags 2048 PT M
- Number of tags 4096 PT N
• with operating system and RTX F
pre-installed and configured P
• with operating system and
HMI/RTX F (incl. archives/recipes)
pre-installed and configured
- Number of tags 128 PT R
- Number of tags 512 PT S
- Number of tags 2048 PT T
- Number of tags 4096 PT U
HMI RT: WinCC flexible 2008
4)
or w/o HMI software 0
HMI RT: WinCC Advanced V11
SP2 (TIA Portal), only with WES7
SP1 and 2 GB RAM
1
Bundles with WinCC RT
Professional (TIA Portal)
("Built to order" with max. delivery
time of 14 working days; only repairs
are possible for hardware)
SIMATIC HMI IPC477C 6AV7884-
7
A
7 7
0 -
7
E
7
0
Fanless
4 x USB 2.0 at rear,
1 x USB 2.0 at front,
1 x COM (RS232),
2 x 10/100/1000 Mbit/s Ethernet
(RJ45);
software pre-installed on CF/SSD:
Windows Embedded Standard 7
SP1,
SIMATIC WinCC Professional V11
SP2
SIMATIC HMI IPC477C PRO 6AV7883-
7
A
7 7
0 -
7
E
7
0
Fanless, 4 x USB 2.0 (500 mA),
1 x USB 2.0 on front (except PRO),
1 x COM (RS232), 24 VDC power
supply with On/Off switch,
2 x PROFINET (IE), Windows
Embedded Standard 7 SP1
pre-installed,
SIMATIC WinCC Professional V11
SP2
Front panel
• 15" TFT Touch 6AV7884- 2
• 19" TFT Touch 6AV7884- 5
• 15" TFT Touch PRO 6AV7883- 6
• 19" TFT Touch PRO 6AV7883- 7
Client configurations
Celeron M processor 1.2 GHz,
1 GB DDR3 RAM,
4 GB CF card,
runtime license 128 PT
A 2 4 Y
Client and stand-alone station
configurations
Core2 Solo processor 1.2 GHz,
2 GB SDRAM-DDR3,
8 GB CF card,
runtime license 128 PT
D 2 4 Y
Core2 Solo processor 1.2 GHz,
PROFIBUS DP,
2 GB SDRAM-DDR3,
8 GB CF card,
runtime license 128 PT
E 2 4 Y
Stand-alone station
configurations
SIMATIC HMI IPC477C 6AV7884-
7
AH3 0 -
7
E
7
0
SIMATIC HMI IPC477C PRO 6AV7883-
7
AH3 0 -
7
E
7
0
Core2 Duo processor 1.2 GHz,
PROFIBUS DP, 4 GB SDRAM-DDR3
• 8 GB CF card 4
• 50 GB SSD (High Endurance) 6
• Runtime license 128 PT Y
• Runtime license 2048 PT V
ST80_2013_EN_Kap05.book Seite 112 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Embedded bundles/Software packages
SIMATIC HMI IPC477C bundles
5/113
Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
Note:
Other ready-to-use SIMATIC HMI IPC477Cs can be found in the
Panel PC chapter under HMI IPC477C.
Please be sure to note:
The HMI IPC477C is delivered as standard with an inserted
CF card. The licenses are located on the supplied USB flash
drive.
Bundles with WinCC V7.0 SP2
incl. Update 1
("Built to order" with max. delivery
time of 14 working days; only repairs
are possible for hardware)
SIMATIC HMI IPC477C 6AV7884-
7
A
7 7
0 -
7
B
7
0
Fanless
4 x USB 2.0 at rear, 1 x USB 2.0
at front, 1 x COM (RS232),
2 x 10/100/1000 Mbit/s Ethernet
(RJ45);
software pre-installed on CF/SSD:
Windows Embedded Standard,
SIMATIC WinCC V7.0 SP1
SIMATIC HMI IPC477C PRO 6AV7883-
7
A
7 7
0 -
7
B
7
0
Fanless, 5 x USB 2.0 (500 mA),
1 x USB 2.0 at front (not on PRO),
1 x COM (RS232), 24 V DC power
supply with On/Off switch,
2 x PROFINET (IE), Windows
Embedded 2009 pre-installed,
SIMATIC WinCC V7.0 SP2 incl.
Update 1 Runtime pre-installed
Front panel
15" TFT Touch 6AV7884- 2
19" TFT Touch 6AV7884- 5
15" TFT Touch PRO 6AV7883- 6
19" TFT Touch PRO 6AV7883- 7
Client configurations
Celeron M processor 1.2 GHz,
1 GB DDR3 RAM, 4 GB CF card,
runtime license 128 PT
A 1 3 X
Client and stand-alone station
configurations
Core2 Solo processor 1.2 GHz,
2 GB SDRAM-DDR3, 8 GB CF card,
runtime license 128 PT
D 2 4 X
Core2 Solo processor 1.2 GHz,
PROFIBUS DP,
2 GB SDRAM-DDR3,
8 GB CF card,
runtime license 128 PT
E 2 4 X
Stand-alone station
configurations
SIMATIC HMI IPC477C 6AV7884-
7
AH3 0 -
7
B
7
0
SIMATIC HMI IPC477C PRO 6AV7883-
7
AH3 0 -
7
B
7
0
Core2 Duo processor 1.2 GHz,
PROFIBUS DP, 4 GB SDRAM-DDR3
8 GB CF card 4
50 GB SSD (High Endurance) 6
• Runtime license 128 PT X
• Runtime license 2048 PT W
Accessories
Protective film
for Panel PCs 477/577/677
For protecting the touch screen
against dirt/scratches
• for 12" Touch 6AV7671-2BA00-0AA0
• for 15" Touch (not for PRO) 6AV7671-4BA00-0AA0
• for 19" Touch 6AV7672-1CE00-0AA0
Labeling membranes
for Panel PCs 477/577/677 6AV7672-0DA00-0AA0
For labeling soft keys and function
keys, blank, supplied in sets of 10
Touch pen 6AV7672-1JB00-0AA0
Captive pen for operation of the
touch devices; holder can be
mounted on the control cabinet or
direct on the PRO unit
Expansion components From page 5/153
ST80_2013_EN_Kap05.book Seite 113 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Embedded bundles/Software packages
Software packages for SIMATIC IPC and S7-mEC
5/114 Siemens ST 80 / ST PC · 2013
5
Overview
HMI complete systems SIMATIC IPC and S7-mEC with SIMATIC WinCC flexible
SIMATIC IPC packages with WinCC flexible are an innovative
solution for simple visualization tasks directly at the machine
in the field of HMI.
This package can only be supplied if a SIMATIC IPC or
S7-mEC (same quantity) is ordered together with the
WinCC flexible Runtime software. It cannot be ordered
subsequently.
In combination with the embedded SIMATIC IPC
(HMI IPC477C (PRO) and IPC427C) and the embedded
controller S7-mEC, there are turn-key solutions (bundles),
i.e. the runtime software is already preinstalled.
SIMATIC IPC with SIMATIC WinCC (TIA Portal)
The SIMATIC IPC packages with WinCC make it easy to order
all the components required for an HMI solution on the basis
of a Panel PC.
This package can only be supplied if a SIMATIC IPC (same
quantity) is ordered together with the WinCC RT Advanced or
WinCC RT Professional software. It cannot be ordered subse-
quently.
In combination with the embedded SIMATIC IPC (IPC277D /
HMI IPC477C (PRO) / IPC477D and IPC227D / IPC427C /
IPC427D) there are turn-key solutions (bundles) available, i.e.
the runtime software is already preinstalled.
SIMATIC IPC with SIMATIC WinAC RTX (F)
The SIMATIC IPC packages with WinAC RTX (F) make it easy
to order all the components required for a control solution on
the basis of an industrial PC.
This package can only be supplied if a SIMATIC Industrial PC
(same quantity) is ordered together with the WinAC RTX
Runtime software. It cannot be ordered subsequently.
In combination with the embedded SIMATIC IPC (IPC277D /
HMI IPC477C (PRO) / IPC477D and IPC227D / IPC427C /
IPC427D) and the S7-mEC embedded controller, there are
turn-key solutions (bundles) available, i.e. the runtime
software is already preinstalled.
ST80_2013_EN_Kap05.book Seite 114 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Embedded bundles/Software packages
Software packages for SIMATIC IPC and S7-mEC
5/115
Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
1)
Only if ordered together with a SIMATIC IPC, SIMATIC Panel PC Ex,
or S7-mEC
2)
Only if ordered together with a SIMATIC IPC
3)
The current version will always be supplied
1)
Only if ordered together with a SIMATIC IPC, SIMATIC Panel PC Ex,
or S7-mEC
2)
Only if ordered together with a SIMATIC IPC
3)
The current version will always be supplied
1)
Only if ordered together with a SIMATIC IPC
2)
The current version will always be supplied
Note:
For ordering data for Panel PCs and accessories,
see configurators in "SIMATIC Panel PCs".
SIMATIC WinCC flexible
package
1) 3)
(incl. archives and recipes)
6AV6623- 2
7
A 0 0 - 0 A A 0
WinCC flexible 2008 Runtime
• 128 PowerTags B
• 512 PowerTags D
2048 PowerTags F
4096 PowerTags G
SIMATIC WinCC package
2)
6AV6382- 2
7
A 0 7 - 2 A X 0
WinCC V7.2 Runtime
2)
• 128 PowerTags C
• 256 Power Tags D
1 024 PowerTags E
8 192 PowerTags H
65 536 PowerTags F
SIMATIC WinCC package
2)
6AV6382- 2
7
A 0 7 - 0 A X 0
WinCC V7.0 SP3 Runtime
2)
• 128 PowerTags C
• 512 PowerTags D
2 048 PowerTags E
8 192 PowerTags H
65 536 PowerTags F
SIMATIC WinCC (TIA Portal)
WinCC Runtime Advanced
Package
1)3)
6AV2114- 2
7
A 0 0 - 0 A A 0
Incl. Recipes + Logging
• 128 PowerTags B
• 512 PowerTags D
2048 PowerTags F
4096 PowerTags H
SIMATIC WinCC Runtime
Professional Package
2)3)
6AV2115- 2
7
A 0 0 - 0 A A 0
• 128 PowerTags B
• 512 PowerTags D
2048 PowerTags F
4096 PowerTags H
8192 PowerTags K
65536 PowerTags M
SIMATIC WinAC RTX (F) package
SIMATIC WinAC RTX
1) 2)
6ES7671-0RC08-6YA0
SIMATIC WinAC RTX F
1) 2)
6ES7671-1RC08-6YA0
Ready-to-use SIMATIC HMI
IPC477C with WinCC
("Built to order" with max. delivery
time of 14 working days; only repairs
are possible for hardware)
SIMATIC HMI IPC477C
with WinCC V7.0 6AV7884-
7
A
7 7
0 -
7
B
7
0
Fanless,
5 x USB2.0 (500 mA),
1 of which at front,
1 x COM (RS232),
power supply 24 V DC
with On/Off switch,
2 x PROFINET (IE),
2 GB main memory
(DDR3-SDRAM),
CompactFlash Card 8 GB;
Windows Embedded 2009
preinstalled;
SIMATIC WinCC V7.0 SP2 Runtime
preinstalled
Client configurations
7
AA1 0 -4B X 0
Celeron M processor, 1.2 GHz,
1 GB SDRAM-DDR3, 8 GB CF card,
runtime license 128 PT
• 15" Touch 3
• 19" Touch 5
Client and stand-alone station
configurations
7
AE2 0 -4B X 0
Core2 Solo processor 1.2 GHz,
2 GB SDRAM-DDR3, 8 GB CF card,
runtime license 128 PT
• 15" Touch 3
• 19" Touch 5
Stand-alone station
configurations
7
AH3 0 -
7
B
7
0
Processor Core2 Duo 1.2 GHz,
4 GB SDRAM-DDR3
• 15" Touch 3
• 19" Touch 5
• 8 GB CF card
7
AH3 0 -4
• 50 GB SSD
7
AH3 0 -6
• Runtime license 128 PT
7
AH3 0 -
7
B X 0
• Runtime license 2048 PT
7
AH3 0 -
7
B W 0
ST80_2013_EN_Kap05.book Seite 115 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Embedded bundles/Software packages
Software packages for SIMATIC IPC and S7-mEC
5/116 Siemens ST 80 / ST PC · 2013
5
Ordering data Order No.
Note:
Other ready-to-use SIMATIC HMI IPC477Cs can be found in the
Panel PC chapter under HMI IPC477C.
More information
Further information can be found in the Internet at:
http://www.automation.siemens.com/simatic-hmi
HMI IPC477C / HMI IPC477C PRO
with WinCC RT Professional
(TIA Portal)
("Built to order" version, max. deliv-
ery time of 15 working days and with
identified repair, if not preferred
type)
SIMATIC HMI IPC477C
with WinCC RT Professional
(TIA Portal)
6AV788 4 -
7
A
77
0 -
7
E
7
0
SIMATIC HMI IPC477C PRO
with WinCC RT Professional
(TIA Portal)
6AV788 3 -
7
A
77
0 -
7
E
7
0
Fan-free
5 x USB 2.0 (500 mA),
one of which on the front
1 x COM (RS232)
24 V DC power supply with
On/Off switch, 2 x PROFINET (IE),
2 GB main memory
(DDR3-SDRAM),
CompactFlash Card 8 GB,
Windows Embedded Standard 7
SP1 pre-installed,
SIMATIC WinCC RT Professional
V11 SP2 pre-installed
Front panels
15" Touch 4 3
15" Touch PRO 3 6
19" Touch 4 5
19" Touch PRO 3 7
Client configurations
7
-
7
AA20 - 4 EY0
Core2 Solo processor 1.2 GHz,
2 GB SDRAM-DDR3, 8 GB CF card,
runtime license 128 PT
Client and stand-alone station
configurations 4 -
7
AA20 - 4 EY0
Core2 Solo processor 1.2 GHz,
2 GB SDRAM-DDR3, 8 GB CF card,
runtime license 128 PT
Stand-alone station
configurations 4 -
7
AH30 -
7
E
7
0
Processor Core2 Duo 1.2 GHz,
4 GB SDRAM-DDR3
8 GB CF card
7
-
7
AH30 - 4 E
7
0
50 GByte SSDe 6
• Runtime license 128 PT
7
-
7
AH30 -
7
EY0
• Runtime license 2048 PT V
ST80_2013_EN_Kap05.book Seite 116 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Industrial monitors and thin clients
SIMATIC Industrial Flat Panel MT
5/117
Siemens ST 80 / ST PC · 2013
Overview
SIMATIC IFP1900 MT Flat Panel Monitor – industrial monitors
with innovative multi-touch operation and brilliant display for the
next generation of operating concepts.
• Installation:
- Equally suited to installation in machines, control cabinets,
consoles, and gantries or in 19" racks
Operator input options:
- Innovative projected capacitive touch technology (PCT)
- Optimized touch technology for industrial requirements with
multi-touch operation
- High protection against incorrect operation thanks to
detection and filtering out of ball of hand, drops of water, and
cleaning operations
Technical specifications
6AV7466-7TB01-0AA0
IFP1900 MT
Display
Screen diagonal 18.5 in
Screen diagonal (cm) 47 cm
Display width 409.8 mm
Display height 230.4 mm
Viewing angle 170° x 170°
Type TFT widescreen display,
LED backlighting
On Screen Display (OSD)
configuration No, can be set with the software
Number of colors (bit levels) 24 bit
Resolution (pixels)
Resolution (WxH in pixel) 1366 x 768
General features
• Detachable from computer unit 30 m
Backlighting
• Backlighting (type) LED
MTBF backlighting
(up to 50%, at 25 °C) 50 000 h; At 25°C
Dimmable backlight Yes; 0-100 %
Control elements
Function keys No
Mouse/cursor control
• external mouse USB
Touch operation
• Touch keyboard Yes
Installation type/mounting
Built-in unit Yes
• Permissible angle to the vertical
backward (console) 35°
• Permissible angle to the vertical
forward (ceiling mounting) 35°
Supply voltage
Type of actuation AC, DC
•AC Yes
•DC Yes
Rated voltage (AC) 0V
Rated voltage (DC) 24 V
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
permissible range, lower limit (AC) 85 V
permissible range, upper limit (AC) 265 V
6AV7466-7TB01-0AA0
IFP1900 MT
ST80_2013_EN_Kap05.book Seite 117 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Industrial monitors and thin clients
SIMATIC Industrial Flat Panel MT
5/118 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
5
Power losses
Power loss AC
• Typical 40 W
• Maximum 60 W
Power loss DC
• Typical 40 W
• Maximum 65 W
Interfaces
USB on the rear 2
Video interfaces
•DVI-D Yes
• Display port Yes; Display port V1.1
Touch interfaces
•USB Yes
Degree and class of protection
IP65 at front Yes
Enclosure Type 4 at the front Yes
NEMA4 at the front No
NEMA4X at the front No
IP20 rear Yes
Standards, approvals, certificates
CE Yes
UL approval
UL 508 Yes
cULus Yes
EN 50081-1 Yes
EN 50081-2 Yes
EN 50082-1 Yes
EN 50082-2 Yes
6AV7466-7TB01-0AA0
IFP1900 MT
Ambient conditions
Min. ambient temperature C
Max. ambient temperature 45 °C
Storage/transport temperature
•Min. -20 °C
•max. 60 °C
Relative humidity
• Relative humidity during operation 95 %
Connection method
Connector for cooling devices Yes
Mechanics/material
Type of housing (front) Aluminum
• Aluminum Yes
Dimensions
Width of the housing front 483 mm
Height of housing front 337 mm
Mounting cutout (W x H x D)
• Mounting cutout, width 465 mm
• Mounting cutout, height 319 mm
Depth/installation dimension 62.5 mm
Weight
Weight without packaging 6.34 kg
Weight incl. packaging 9.52 kg
6AV7466-7TB01-0AA0
IFP1900 MT
ST80_2013_EN_Kap05.book Seite 118 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Industrial monitors and thin clients
SIMATIC Industrial Flat Panel MT
5/119
Siemens ST 80 / ST PC · 2013
Ordering data
Order No.
Dimensional drawings
All dimensions in mm. For mounting cut-out see technical
specifications.
Mounting dimensions
SIMATIC IFP1900 MT 6AV7466-7TB01-0AA0
Flat Panel, 19" display (16:9),
operation using multitouch gestures,
extended version up to 30 m,
1366 x 768 pixels,
for 24 V DC and 100-240 V AC,
display port/DVI interface,
incl. 1.8 m DVI/USB cable
Industrial
Flat Panel MT Front dimensions
in mm Mounting Cutout, in mm
W H W+1 H+1 D
IFP1900 483 337 465 319 93
H
W
W+1
H+1
6.5D
G_ST80_XX_00522
ST80_2013_EN_Kap05.book Seite 119 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Industrial monitors and thin clients
SIMATIC Industrial Flat Panel
5/120 Siemens ST 80 / ST PC · 2013
5
Overview
The Industrial Flat Panels are rugged industry-standard LCD
monitors in a wide screen design.
Installation:
- Equally suited for installation in the machine, in control
cabinets, in consoles, to gantries, or in 19" racks.
Type of operator control:
- Simple display devices without operator functionality
- Optional devices with touch control
- Rear-mounted connection of I/O devices (optional).
Technical specifications
6AV7863-2AA00-0AA0 6AV7863-2AB10-0AA0 6AV7863-2TA00-0AA0 6AV7863-2TB10-0AA0
IFP1500 IFP1500 IFP1500 IFP1500
General information
Short designation Flat Panel 15" display Flat Panel 15" display ext. Flat Panel 15" Touch Flat Panel 15" Touch ext.
Display
Screen diagonal 15.4 in 15.4 in 15.4 in 15.4 in
Screen diagonal (cm) 40 cm 40 cm 40 cm 40 cm
Display width 331.2 mm 331.2 mm 331.2 mm 331.2 mm
Display height 207 mm 207 mm 207 mm 207 mm
Viewing angle 170° x 170° 170° x 170° 170° x 170° 170° x 170°
Type TFT widescreen display,
LED backlighting TFT widescreen display,
LED backlighting TFT widescreen display,
LED backlighting TFT widescreen display,
LED backlighting
On Screen Display (OSD)
configuration No, can be set with the
software No, can be set with the
software No, can be set with the
software No, can be set with the
software
Number of colors (bit levels) 24 bit 24 bit 24 bit 24 bit
Number of colors 16 777 200 16 777 200 16 777 200 16 777 200
Resolution (pixels)
• Horizontal image resolution 1 280 1 280 1 280 1 280
Vertical image resolution 800 800 800 800
Pixel size, horizontal 0.259 mm 0.259 mm 0.259 mm 0.259 mm
Pixel size, vertical 0.259 mm 0.259 mm 0.259 mm 0.259 mm
General features
Non-reflective and tempered mineral
glass screen Yes Yes
• Detachable from computer unit 5m 30 m 5m 5m
• Brightness/contrast 400 cd/m² / 1000:1 400 cd/m² / 1000:1 400 cd/m² / 1000:1 400 cd/m² / 1000:1
•Brightness, max. 400 cd/m² 400 cd/m² 400 cd/m² 400 cd/m²
Backlighting
• Backlighting (type) LED LED LED LED
MTBF backlighting
(up to 50%, at 25 °C) 50 000 h; At 25°C 50 000 h; At 25°C 50 000 h; At 25°C 50 000 h; At 25°C
Dimmable backlight Yes; 0-100 % Yes; 0-100 % Yes; 0-100 % Yes; 0-100 %
ST80_2013_EN_Kap05.book Seite 120 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Industrial monitors and thin clients
SIMATIC Industrial Flat Panel
5/121
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
Control elements
Function keys No No No No
Mouse/cursor control
• external mouse USB USB
Keyboard fonts
Alphanumeric and numeric block Yes
Touch operation
Touch keyboard Yes Yes
Installation type/mounting
Built-in unit Yes Yes Yes Yes
Permissible angle to the vertical
backward (console) 35° 35° 35° 35°
Permissible angle to the vertical
forward (ceiling mounting) 35° 35° 35° 35°
Supply voltage
Type of actuation DC DC DC DC
•AC Yes Yes
•DC Yes Yes Yes Yes
Rated voltage (AC) 100 V; Up to 240V 50/60Hz
Rated voltage (DC) 24 V 24 V 24 V 24 V
permissible range, lower limit (DC) 19.2 V 19.2 V 19.2 V 19.2 V
permissible range, upper limit (DC) 28.8 V 28.8 V 28.8 V 28.8 V
permissible range, lower limit (AC) 90 V 90 V
permissible range, upper limit (AC) 264 V 264 V
Power losses
Power loss AC
• Typical 40 W 40 W
• Maximum 60 W 60 W
Power loss DC
• Typical 40 W 40 W 40 W 40 W
• Maximum 65 W 65 W 65 W 65 W
Interfaces
USB on the rear 2 2
Video interfaces
•DVI-D Yes Yes Yes Yes
• Display port Yes; Display port V1.1 Yes; Display port V1.1 Yes; Display port V1.1 Yes; Display port V1.1
Touch interfaces
•USB No No Yes Yes
Degree and class of protection
IP65 at front Yes Yes Yes Yes
Enclosure Type 4 at the front Yes Yes Yes Yes
NEMA4 at the front No No No No
NEMA4X at the front No No No No
IP20 rear Yes Yes Yes Yes
6AV7863-2AA00-0AA0 6AV7863-2AB10-0AA0 6AV7863-2TA00-0AA0 6AV7863-2TB10-0AA0
IFP1500 IFP1500 IFP1500 IFP1500
ST80_2013_EN_Kap05.book Seite 121 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Industrial monitors and thin clients
SIMATIC Industrial Flat Panel
5/122 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
5
Standards, approvals, certificates
CE Yes Yes Yes Yes
KC approval Yes Yes Yes Yes
cULus Yes; Corresponds to
UL 508 Yes; Corresponds to
UL 508 Yes; Corresponds to
UL 508 Yes; Corresponds to
UL 508
C-TICK Yes Yes Yes Yes
GL Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon
ABS Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon
BV Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon
DNV Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon
LRS Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon
Class NK Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon
Use in hazardous areas
• ATEX Zone 22 Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon
• FM Class I Division 2 Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon
Ambient conditions
Min. ambient temperature C 0°C 0°C 0°C
Max. ambient temperature 50 °C; Vertical installation
(horizontal) 50 °C; Vertical installation
(horizontal) 50 °C; Vertical installation
(horizontal) 50 °C; Vertical installation
(horizontal)
Storage/transport temperature
•Min. -20 °C -20 °C -20 °C -20 °C
•max. 60 °C 60 °C 60 °C 60 °C
Relative humidity
Relative humidity during operation 95 %; Non-condensing 95 %; Non-condensing 95 %; Non-condensing 95 %; Non-condensing
Vibrations
• Vibration load in operation 1g1g1g1g
• Vibration load during
transport/storage 1g1g1g1g
Shock testing
• Shock loading in operation 15 g15 g15 g15 g
Shock load during transport/storage 15 g15 g15 g15 g
Connection method
Connector for cooling devices Yes
Mechanics/material
Type of housing (front) Aluminum Aluminum Aluminum Aluminum
• Aluminum Yes Yes Yes Yes
Dimensions
Width of the housing front 415 mm 415 mm 415 mm 415 mm
Height of housing front 310 mm 310 mm 310 mm 310 mm
Depth/installation dimension 62.5 mm 62.5 mm 62.5 mm 62.5 mm
Mounting cutout, width 396 mm; Tolerance: +1 mm 396 mm; Tolerance: +1 mm 396 mm; Tolerance: +1 mm 396 mm; Tolerance: +1 mm
Mounting cutout, height 291 mm; Tolerance: +1 mm 291 mm; Tolerance: +1 mm 291 mm; Tolerance: +1 mm 291 mm; Tolerance: +1 mm
Weight
Weight without packaging 3.9 kg 3.9 kg 3.9 kg 3.9 kg
Weight incl. packaging 5kg 5kg 5kg 5kg
6AV7863-2AA00-0AA0 6AV7863-2AB10-0AA0 6AV7863-2TA00-0AA0 6AV7863-2TB10-0AA0
IFP1500 IFP1500 IFP1500 IFP1500
ST80_2013_EN_Kap05.book Seite 122 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Industrial monitors and thin clients
SIMATIC Industrial Flat Panel
5/123
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
6AV7 863-3AA00-0AA0 6AV7 863-3AB10-0AA0 6AV7 863-3TA00-0AA0 6AV7 863-3TB10-0AA0
IFP1900 IFP1900 IFP1900 IFP1900
General information
Short designation Flat Panel 19" display Flat Panel 19" display ext. Flat Panel 19" Touch Flat Panel 19" Touch ext.
Display
Screen diagonal 18.5 in 18.5 in 18.5 in 18.5 in
Screen diagonal (cm) 47 cm 47 cm 47 cm 47 cm
Display width 409.8 mm 409.8 mm 409.8 mm 409.8 mm
Display height 230.4 mm 230.4 mm 230.4 mm 230.4 mm
Type TFT TFT TFT TFT
On Screen Display (OSD)
configuration No, can be set
with the software No, can be set
with the software No, can be set
with the software No, can be set
with the software
Number of colors (bit levels) 24 bit 24 bit 24 bit 24 bit
Resolution (pixels)
Resolution (WxH in pixel) 1366 x 768 1366 x 768 1366 x 768 1366 x 768
Pixel size, horizontal 0.3 mm 0.3 mm 0.3 mm 0.3 mm
Pixel size, vertical 0.3 mm 0.3 mm 0.3 mm 0.3 mm
General features
Non-reflective and tempered mineral
glass screen Yes Yes
• Detachable from computer unit 5m 30 m 5m 30 m
Backlighting
• Backlighting (type) LED LED LED LED
MTBF backlighting
(up to 50%, at 25 °C) 50 000 h; At 25°C 50 000 h; At 25°C 50 000 h; At 25°C 50 000 h; At 25°C
Dimmable backlight Yes; 0-100 % Yes; 0-100 % Yes; 0-100 % Yes; 0-100 %
Control elements
Function keys No No No No
Mouse/cursor control
• external mouse USB USB
Touch operation
Touch keyboard Yes Yes
Installation type/mounting
Built-in unit Yes Yes Yes Yes
Permissible angle to the vertical
backward (console) 35° 35° 35° 35°
Permissible angle to the vertical
forward (ceiling mounting) 35° 35° 35° 35°
ST80_2013_EN_Kap05.book Seite 123 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Industrial monitors and thin clients
SIMATIC Industrial Flat Panel
5/124 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
5
Supply voltage
Type of actuation DC DC DC DC
•AC Yes Yes
•DC Yes Yes Yes Yes
Rated voltage (AC) 100 V; Up to 240V 50/60Hz 100 V; Up to 240V 50/60Hz
Rated voltage (DC) 24 V 24 V 24 V 24 V
permissible range, lower limit (DC) 19.2 V 19.2 V 19.2 V 19.2 V
permissible range, upper limit (DC) 28.8 V 28.8 V 28.8 V 28.8 V
permissible range, lower limit (AC) 90 V 90 V
permissible range, upper limit (AC) 264 V 264 V
Power losses
Power loss AC
• Typical 40 W 40 W
• Maximum 60 W 60 W
Power loss DC
• Typical 40 W 40 W 40 W 40 W
• Maximum 65 W 65 W 65 W 65 W
Interfaces
USB on the rear 2 2
Video interfaces
•DVI-D Yes Yes Yes Yes
• Display port Yes; Display port V1.1 Yes; Display port V1.1 Yes; Display port V1.1 Yes; Display port V1.1
Touch interfaces
•USB No No Yes Yes
Degree and class of protection
IP65 at front Yes Yes Yes Yes
Enclosure Type 4 at the front Yes Yes Yes Yes
NEMA4 at the front No No No No
NEMA4X at the front No No No No
IP20 rear Yes Yes Yes Yes
Standards, approvals, certificates
CE Yes Yes Yes Yes
KC approval Yes Yes Yes Yes
cULus Yes; Corresponds to UL
508 Yes; Corresponds to UL
508 Yes; Corresponds to UL
508 Yes; Corresponds to UL
508
C-TICK Yes Yes Yes Yes
GL Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon
ABS Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon
BV Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon
DNV Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon
LRS Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon
Class NK Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon
Use in hazardous areas
• ATEX Zone 22 Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon
• FM Class I Division 2 Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon
6AV7 863-3AA00-0AA0 6AV7 863-3AB10-0AA0 6AV7 863-3TA00-0AA0 6AV7 863-3TB10-0AA0
IFP1900 IFP1900 IFP1900 IFP1900
ST80_2013_EN_Kap05.book Seite 124 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Industrial monitors and thin clients
SIMATIC Industrial Flat Panel
5/125
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
Ambient conditions
Min. ambient temperature C 0°C 0°C 0°C
Max. ambient temperature 45 °C; Vertical installation
(horizontal) 45 °C; Vertical installation
(horizontal) 45 °C; Vertical installation
(horizontal) 45 °C; Vertical installation
(horizontal)
Storage/transport temperature
•Min. -20 °C -20 °C -20 °C -20 °C
•max. 60 °C 60 °C 60 °C 60 °C
Relative humidity
Relative humidity during operation 95 %; Non-condensing 95 %; Non-condensing 95 %; Non-condensing 95 %; Non-condensing
Vibrations
• Vibration load in operation 1g1g1g1g
• Vibration load during transport/stor-
age 1g1g1g1g
Shock testing
• Shock loading in operation 15 g15 g15 g15 g
Shock load during transport/storage 15 g15 g15 g15 g
Connection method
Connector for cooling devices Yes Yes
Mechanics/material
Type of housing (front) Aluminum Aluminum Aluminum Aluminum
• Aluminum Yes Yes Yes Yes
Dimensions
Width of the housing front 483 mm 483 mm 483 mm 483 mm
Height of housing front 337 mm 337 mm 337 mm 337 mm
Mounting cutout (W x H x D)
Mounting cutout, width 465 mm; Tolerance: +1 mm 465 mm; Tolerance: +1 mm 465 mm; Tolerance: +1 mm 465 mm; Tolerance: +1 mm
Mounting cutout, height 319 mm; Tolerance: +1 mm 319 mm; Tolerance: +1 mm 319 mm; Tolerance: +1 mm 319 mm; Tolerance: +1 mm
Depth/installation dimension 62.5 mm 62.5 mm 62.5 mm 62.5 mm
Weight
Weight without packaging 5.5 kg 5.5 kg 5.5 kg 5.5 kg
Weight incl. packaging 6.5 kg 6.5 kg 6.5 kg 6.5 kg
6AV7 863-3AA00-0AA0 6AV7 863-3AB10-0AA0 6AV7 863-3TA00-0AA0 6AV7 863-3TB10-0AA0
IFP1900 IFP1900 IFP1900 IFP1900
ST80_2013_EN_Kap05.book Seite 125 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Industrial monitors and thin clients
SIMATIC Industrial Flat Panel
5/126 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
5
6AV7 863-4AA00-0AA0 6AV7 863-4AB10-0AA0 6AV7 863-4TA00-0AA0 6AV7 863-4TB10-0AA0
IFP2200 IFP2200 IFP2200 IFP2200
General information
Short designation Flat Panel 22" display Flat Panel 22" display ext. Flat Panel 19" Touch Flat Panel 22" Touch ext.
Display
Screen diagonal 21.5 in 21.5 in 21.5 in 21.5 in
Screen diagonal (cm) 56 cm 56 cm 56 cm 56 cm
Display width 476 mm 476 mm 476 mm 476 mm
Display height 268 mm 268 mm 268 mm 268 mm
Viewing angle 170° x 170° 170° x 170° 170° x 170° 170° x 170°
Type TFT TFT TFT TFT
On Screen Display (OSD)
configuration No, can be set
with the software No, can be set
with the software No, can be set
with the software No, can be set
with the software
Number of colors (bit levels) 24 bit 24 bit 24 bit 24 bit
Resolution (pixels)
Resolution (WxH in pixel) 1920 x 1080 1920 x 1080 1920 x 1080 1920 x 1080
Pixel size, horizontal 0.2475 mm 0.2475 mm 0.2475 mm 0.2475 mm
Pixel size, vertical 0.2475 mm 0.2475 mm 0.2475 mm 0.2475 mm
General features
Non-reflective and tempered
mineral glass screen Yes Yes
• Detachable from computer unit 5m 30 m 5m 30 m
• Brightness/contrast 250 cd/m² / 1000:1 250 cd/m² / 1000:1 250 cd/m² / 1000:1 250 cd/m² / 1000:1
Backlighting
• Backlighting (type) LED LED LED LED
MTBF backlighting
(up to 50%, at 25 °C) 50 000 h; At 25°C 50 000 h; At 25°C 50 000 h; At 25°C 50 000 h; At 25°C
Dimmable backlight Yes; 0-100 % Yes; 0-100 % Yes; 0-100 % Yes; 0-100 %
Control elements
Function keys No No No No
Mouse/cursor control
• external mouse USB USB
Touch operation
Touch keyboard Yes Yes
Installation type/mounting
Built-in unit Yes Yes Yes Yes
Permissible angle to the vertical
backward (console) 35° 35° 35° 35°
Permissible angle to the vertical
forward (ceiling mounting) 35° 35° 35° 35°
Supply voltage
Type of actuation DC DC DC DC
•AC Yes Yes
•DC Yes Yes Yes Yes
Rated voltage (AC) 100 V; Up to 240V 50/60Hz 100 V; Up to 240V 50/60Hz
Rated voltage (DC) 24 V 24 V 24 V 24 V
permissible range, lower limit (DC) 19.2 V 19.2 V 19.2 V 19.2 V
permissible range, upper limit (DC) 28.8 V 28.8 V 28.8 V 28.8 V
permissible range, lower limit (AC) 90 V 90 V
permissible range, upper limit (AC) 264 V 264 V
ST80_2013_EN_Kap05.book Seite 126 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Industrial monitors and thin clients
SIMATIC Industrial Flat Panel
5/127
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
Power losses
Power loss AC
• Typical 40 W 40 W
• Maximum 60 W 60 W
Power loss DC
• Typical 40 W 40 W 40 W 40 W
• Maximum 65 W 65 W 65 W 65 W
Interfaces
USB on the rear 2 2
Video interfaces
•DVI-D Yes Yes Yes Yes
• Display port Yes; Display port V1.1 Yes; Display port V1.1 Yes; Display port V1.1 Yes; Display port V1.1
Touch interfaces
•USB No No Yes Yes
Degree and class of protection
IP65 at front Yes Yes Yes Yes
Enclosure Type 4 at the front Yes Yes Yes Yes
NEMA4 at the front No No No No
NEMA4X at the front No No No No
IP20 rear Yes Yes Yes Yes
Standards, approvals, certificates
CE Yes Yes Yes Yes
KC approval Yes Yes Yes Yes
cULus Yes; Corresponds to
UL 508 Yes; Corresponds to
UL 508 Yes; Corresponds to
UL 508 Yes; Corresponds to
UL 508
C-TICK Yes Yes Yes Yes
GL Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon
ABS Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon
BV Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon
DNV Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon
LRS Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon
Class NK Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon
Use in hazardous areas
• ATEX Zone 22 Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon
• FM Class I Division 2 Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon
Ambient conditions
Min. ambient temperature C 0°C 0°C 0°C
Max. ambient temperature 45 °C; Vertical installation
(horizontal) 45 °C; Vertical installation
(horizontal) 45 °C; Vertical installation
(horizontal) 45 °C; Vertical installation
(horizontal)
Storage/transport temperature
•Min. -20 °C -20 °C -20 °C -20 °C
•max. 60 °C 60 °C 60 °C 60 °C
Relative humidity
Relative humidity during operation 95 %; Non-condensing 95 %; Non-condensing 95 %; Non-condensing 95 %; Non-condensing
Vibrations
• Vibration load in operation 1g1g1g1g
• Vibration load during
transport/storage 1g1g1g1g
Shock testing
• Shock loading in operation 15 g15 g15 g15 g
Shock load during transport/storage 15 g15 g15 g15 g
6AV7 863-4AA00-0AA0 6AV7 863-4AB10-0AA0 6AV7 863-4TA00-0AA0 6AV7 863-4TB10-0AA0
IFP2200 IFP2200 IFP2200 IFP2200
ST80_2013_EN_Kap05.book Seite 127 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Industrial monitors and thin clients
SIMATIC Industrial Flat Panel
5/128 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
5
Ordering data
Order No. Order No.
Connection method
Connector for cooling devices Yes Yes
Mechanics/material
Type of housing (front) Aluminum Aluminum Aluminum Aluminum
• Aluminum Yes Yes Yes Yes
Dimensions
Width of the housing front 560 mm 560 mm 560 mm 560 mm
Height of housing front 380 mm 380 mm 380 mm 380 mm
Mounting cutout (W x H x D)
Mounting cutout, width 542 mm; Tolerance: +1 mm 542 mm; Tolerance: +1 mm 542 mm; Tolerance: +1 mm 542 mm; Tolerance: +1 mm
Mounting cutout, height 362 mm; Tolerance: +1 mm 362 mm; Tolerance: +1 mm 362 mm; Tolerance: +1 mm 362 mm; Tolerance: +1 mm
Depth/installation dimension 62.5 mm 62.5 mm 62.5 mm 62.5 mm
Weight
Weight without packaging 6.5 kg 6.5 kg 6.5 kg 6.5 kg
Weight incl. packaging 7.6 kg 7.6 kg 7.6 kg 7.6 kg
6AV7 863-4AA00-0AA0 6AV7 863-4AB10-0AA0 6AV7 863-4TA00-0AA0 6AV7 863-4TB10-0AA0
IFP2200 IFP2200 IFP2200 IFP2200
Industrial Flat Panel Monitor 6AV7863- 7777- 0 A A 0
Display size
• 15“ 2
• 19“ 3
• 22“ 4
Operator functionality
• Display devices without operator
functionality A
Touch screen (analog/resistive) T
Touch screen + function keys,
15" only and extended special
functions
BB1
Special functions
• Standard, can be located
up to 5 m away A0
Extended, for positioning
at a distance of up to 30 m,
100 ... 230 V AC (without supply
cable) + special functions
B1
Accessories
Set of protective films
for ITC/IFP/TP1500 6AV2124-6QJ00-0AX1
Set of protective films
for ITC/IFP/TP1900 6AV2124-6UJ00-0AX1
Set of protective films
for ITC/IFP/TP2200 6AV2124-6XJ00-0AX1
Touch pen 6AV7672-1JB00-0AA0
Undetachable pen for operation
of the touch devices,
mounting of the support on the
control cabinet or directly on the
PRO unit
Accessories for standard variants
up to 5 m (6AV7863-..A0.-0AA0)
DisplayPort cable
(industrial quality)
•3 m 6AV7860-0DH30-0AA0
•5 m 6AV7860-0DH50-0AA0
DVI-D cable (industrial quality)
•3 m 6AV7860-0BH30-0AA0
•5 m 6AV7860-0BH50-0AA0
USB cable (industrial quality)
•3 m 6AV7860-0CH30-0AA0
•5 m 6AV7860-0CH50-0AA0
Accessories for extended variants
up to 30 m (6AV7863-..B1.-0AA0)
Cable set (USB/Cat5;
sender module, DVI)
•10 m 6AV7860-1EX21-0AA1
•15 m 6AV7860-1EX21-5AA1
•20 m 6AV7860-1EX22-0AA1
•30 m 6AV7860-1EX23-0AA1
Cable set 90° 6AV7860-1EX22-0BA1
USB/Cat5; sender module,
DVI 90° angle, 20 m
USB host extender 6AV7671-1EX02-0AA0
incl. 20 cm USB cable (USB to Cat5)
ST80_2013_EN_Kap05.book Seite 128 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Industrial monitors and thin clients
SIMATIC Industrial Flat Panel
5/129
Siemens ST 80 / ST PC · 2013
Dimensional drawings
All dimensions in mm. For mounting cut-out see technical
specifications. Mounting dimensions
H
W
W+1
H+1
6.5D
G_ST80_XX_00522
Industrial
Flat Panel Faceplate Dimen-
sions, in mm Mounting Cutout, in mm
W H W+1 H+1 D
IF1500
Key/Touch 483 310 450 291 62.5
IFP1500 415 310 396 291 62.5
IFP1900 483 337 465 319 62.5
IFP2200 560 380 542 362 62.5
ST80_2013_EN_Kap05.book Seite 129 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Industrial monitors and thin clients
SIMATIC Flat Panels
5/130 Siemens ST 80 / ST PC · 2013
5
Overview
The Flat Panels are rugged industry-standard LCD monitors.
Installation:
- They are equally suited to installation in the machine, in
control cabinets, consoles and gantries or in 19" racks.
- As a device with all-round IP65 protection for mounting on
a supporting arm/stand
Type of operator control:
- Simple display devices without operator functionality
- Optional devices with touch control
- Rear connection of I/O devices (optional)
Technical specifications
Flat Panel 12“ 15“ 19“
Supply voltage
Supply voltage 24 V DC, additional option
100-240 V AC 24 V DC, additional option
100-240 V AC 24 V DC, additional option
100/240 V AC
Permissible frequency range 47 - 63 Hz 47 - 63 Hz 47 - 63 Hz
Power consumption, max. 25 VA 35 VA 55 VA
General features
Anti-glare and hardened
mineral glass screen Yes Yes Yes
Line side switch No No No
Can be separate from the computer Optional up to 30 m Optional up to 30 m Optional up to 30 m
Display
On-screen display (OSD)
configuration Yes Yes Yes
Display version 12" TFT 15" TFT 19" TFT
Visible area (HxV) in mm 246 x 184.5 304 x 228 376 x 301
Viewing angle 140° x 120° 140° x 120° (min) 170° x 170°
Pixel pitch 0.3075 mm x 0.3075 mm 0.297 mm x 0.297 mm 0.294 mm x 0.294 mm
Resolution (W x H in pixels) 800 x 600 1024 x 768 1280 x 1024
Refresh rate 60 - 75 Hz 60 - 75 Hz 60 - 75 Hz
Line frequency 25 - 48 kHz 46.7 - 62.5 kHz 30 - 80 KHz
Brightness/Contrast > 350 cd/m² / 450:1 > 260cd/m² / 350:1 > 300cd/m² / 300:1
Number of colors 262k 16.7 million 16.7 million
MTBF backlit display
(at 25 °C, 24 h continuous duty) 50.000 h 50.000 h 50.000 h
Type of operation
Touch screen analog-resistive, optional analog-resistive, optional analog-resistive, optional
Connection for mouse/keyboard/
barcode reader Yes, at rear, optionally via USB Yes, at rear, optionally via USB Yes, at rear, optionally via USB
Degree of protection
Front side according to EN 60529 IP65 IP65 IP65
Rear side according to EN 60529 IP20 IP20 IP20
ST80_2013_EN_Kap05.book Seite 130 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Industrial monitors and thin clients
SIMATIC Flat Panels
5/131
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
Certifications & standards
Certification cULus (UL 508), NEMA4 tested cULus (UL 508), NEMA4 tested cULus (UL 508), NEMA4 tested
EMC CE EN 55011 class A CE EN 55011 class A CE EN 55011 class A
Standards, approvals, certificates
CE mark Yes Yes Yes
UL approval Yes Yes Yes
CCC marking Yes Yes Yes
Ambient conditions
Vibration load during operation 1 g (10 m/s²) 1 g (10 m/s²) 1 g (10 m/s²)
Shock loading during operation 5 g (50 m/s²) 5 g (50 m/s²) 5 g (50 m/s²)
Temperature
Ambient temperature during operation 5 to +50°C 5 to +50°C 5 to +45°C
Mounting
Rack mounting No No No
Front mounting Yes (IP65) Yes (IP65) Yes (IP65)
Angle of inclination for desk mounting -20°/+70° -20°/+70° -20°/+70°
Interfaces
Graphics interface Standard VGA interface 15-pin
Sub D / digital DVI-D interface Standard VGA interface 15-pin
Sub D / digital DVI-D interface Standard VGA interface 15-pin
Sub D / digital DVI-D interface
Interface for Touch USB (V1.1) USB (V1.1) USB (V1.1)
USB interface for touch screen Optional Optional Optional
Dimensions
External dimensions
(W x H x D) in mm 400 x 310 x 61.5 483 x 310 x 54 483 x 400 x 56
Installation cutout/device depth
(W x H x D) in mm 368 x 290 x 51 450 x 290 x 54 449 x 380 x 56
Weight
Weight, approx. 5 kg 6.4 kg 10.2 kg
Flat Panel 12“ 15“ 19“
ST80_2013_EN_Kap05.book Seite 131 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Industrial monitors and thin clients
SIMATIC Flat Panels
5/132 Siemens ST 80 / ST PC · 2013
5
Ordering data
Order No. Order No.
Flat Panel Monitor 6AV7861- 77770- 11 A A 0
Display size
• 12“ 1
• 15“ 2
• 19“ 3
Operator functionality:
• Display devices
without operator functionality A
Touch screen (analog/resistive) T
Power supply
24 VDC
(not for Extended versions since
these always have AC and DC)
A0
100 to 230 V AC (incl. Euro power
supply cable) and 24 V DC B
Version
• Standard, can be located
up to 5 m away 0
Extended, can be located
up to 30 m away,
marine approvals
Dimmable background illumination
Ex22
1
Special versions
Flat Panel Monitor
• 12" Key 6AV7861-1KB10-1AA0
• 15" Key 6AV7861-2KB10-1AA0
• PRO 15" Touch 6AV7861-5TB10-1BA0
• PRO 19" Touch 6AV7861-6TB10-1BA0
Accessories
Protective films
For protecting the touch screen
against dirt and scratches
Pack with 10 units
• for 12" Touch 6AV7671-2BA00-0AA0
• for 15" Touch 6AV7671-4BA00-0AA0
• for 19" Touch 6AV7672-1CE00-0AA0
Touch pen
Undetachable pen for operation
of the touch devices,
mounting of the support on the
control cabinet or directly on the
PRO unit
6AV7672-1JB00-0AA0
Connection cables for Standard,
Extended and PRO versions
• Video (VGA)
-3.0 m 6AV7860-0AH30-0AA0
-5.0 m 6AV7860-0AH50-0AA0
• Video (DVI-D)
-3.0 m 6AV7860-0BH30-0AA0
-5.0 m 6AV7860-0BH50-0AA0
• USB for optional touch screen
-3.0 m 6AV7860-0CH30-0AA0
-5.0 m 6AV7860-0CH50-0AA0
Connection cables for
Extended and PRO versions
• Cable set 10 m
(DVI-D, CAT5 cable (USB),
USB transmitter module)
6AV7860-1EX21-0AA1
• Cable set 15 m
(DVI-D, CAT5 cable (USB),
USB transmitter module)
6AV7860-1EX21-5AA1
• Cable set 20 m
(DVI-D, CAT5 cable (USB),
USB transmitter module)
6AV7860-1EX22-0AA1
• Cable set 30 m
(DVI-D, CAT5 cable (USB),
USB transmitter module)
6AV7860-1EX23-0AA1
ST80_2013_EN_Kap05.book Seite 132 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Industrial monitors and thin clients
SIMATIC Flat Panels
5/133
Siemens ST 80 / ST PC · 2013
Dimensional drawings
All dimensions in mm. For mounting cut-out see technical specifications.
Installation cutout for Flat Panel Flat Panel PRO 15" Touch
Flat Panel PRO 19" Touch
More information
Additional information is available on the Internet at:
http://www.siemens.com/industrial-lcd
Note:
Do you need a specific modification or extension to the products
described here? Then refer to "Customized Automation". There
you will find information about additional and generally available
sector-specific products as well as options for customer-specific
modification and adaptation.
Examples are:
SIMATIC SCD monitor 1900 for portrait operation
SIMATIC Flat Panels with 6" and 10" Touch
Touch devices Front dimensions Installation cutout
W H W+1 H+1 D
12" 400 310 368 290 51
15" 483 310 450 290 55
19" 483 400 450 380 57
H
W
W+1 (cutout)
H+1 (cutout)
D10.5
G_ST80_XX_00238
400
310
67.85
90.85
G_ST80_XX_00350
G_ST80_XX_00371
82
105
483
400
SIMATIC FLAT PANEL
ST80_2013_EN_Kap05.book Seite 133 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Industrial monitors and thin clients
SCD desk monitors SCD 19101
5/134 Siemens ST 80 / ST PC · 2013
5
Overview
The SCD 19101 D/DT monitors are LCD desktop monitors for
use in industry.
Type of operator control:
Simple display devices
Panels with touch control
Technical specifications
Ordering data
Order No.
19" monitors SCD 19101-D/-DT
General features
Supply voltage
• Supply voltage 110/230 V AC
• Frequency/power consumption 47 - 63 Hz/30 VA
• Line side switch No
• Representation Full screen
Display
• Display version 19" TFT
• Screen diagonals 19"
visible area (HxV) in mm 359 x 287
• Viewing angle 170° x 170°
•Pixel pitch 0.28 x 0.28
• Optimum resolution (in pixels) 1280 x 1024
• Refresh rate 30 - 100 Hz
• Line frequency 50 - 97 KHz
• Brightness/contrast (typical) 270 cd/m
2
/400:1
• Number of colors 16 million
• MTBF of backlit display
(up to 50%, at 25 °C) 50,000 h
Type of operation
• Function keys No
• Membrane keyboard & piezo mouse No
• Touch screen Optional
Degree of protection
• Degree of protection
according to EN 60529 IP20
Ambient conditions
•Temperature
- Ambient temperature
during operation 0 to +40°C
Interfaces
Interface design, analog video signal
(VGA) Yes
PS/2 interfaces for keyboard & mouse No
• Serial interface for touch screen Optional/serial
Dimensions
• External dimensions
(W x H x D) in mm 465 x 444 x 91
(stand depth 240)
• Installation cutout/depth
(W x H x D) in mm 465 x 444 x 91
(stand depth 240)
•Weight in kg 7
19" LCD monitors 6GF6220-1DA01
SCD 19101-D, desktop model
19" Touch LCD monitors 6GF6220-1DB01
SCD 19101-DT, desktop model
ST80_2013_EN_Kap05.book Seite 134 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Industrial monitors and thin clients
SCD desk monitors SCD 19101
5/135
Siemens ST 80 / ST PC · 2013
Dimensional drawings
All dimensions in mm. For mounting cut-out see technical specifications.
SCD 19101-D/DT
More information
Additional information is available in the Internet under:
http://www.siemens.com/industrial-lcd
287.6
G_ST80_XX_00031
393
47
91 20
240
393
380
465
160
444
15"
5"
ST80_2013_EN_Kap05.book Seite 135 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Industrial monitors and thin clients
SCD monitors 1900
5/136 Siemens ST 80 / ST PC · 2013
5
Overview
The SIMATIC HMI SCD 1900 is a rugged, industry-standard PC
monitor.
It is used as an operator control unit in all types of industrial and
standard PC, including for portrait mounting. Standard inter-
faces permit a wide range of possible applications.
Built-in versions:
Built-in unit (for control cabinets, control desks, and gantries)
Built-in portrait for portrait mounting
(for control cabinets, control desks and gantries)
19" built-in units (for 19" racks)
Type of operator control:
Panels with touch control
Technical specifications
6AV7862-2TA00-1AA0
SCD 1900
General information
Short designation Flat Panel 19" Touch
Display
Screen diagonal 19 in
visible area (HxV) in mm 255 x 408
Viewing angle 160° x 170°
Type TFT widescreen display,
LED backlighting
On Screen Display (OSD)
configuration Yes
Number of colors (bit levels) 24 bit
Backlighting
MTBF backlighting
(up to 50%, at 25 °C) 50 000 h
Installation type/mounting
Rack mounting possible Yes
Built-in unit Yes
VESA mounting No
Supply voltage
Type of actuation DC
•AC Yes; With an external
power supply unit
•DC Yes
permissible range, lower limit (DC) 21.6 V
permissible range, upper limit (DC) 26.4 V
Interfaces
Video interfaces
•VGA Yes
•DVI-D Yes
Touch interfaces
•USB Yes
Degree and class of protection
IP65 at front Yes
IP20 rear Yes
Standards, approvals, certificates
CE Yes; Industry
CSA No
UL Yes
cULus Yes
Ambient conditions
Storage/transport temperature
•Min. -20 °C
•max. 60 °C
Shock testing
• Shock loading in operation 10 g
• Shock load during transport/storage 10 g
Mechanics/material
Type of housing (front)
• Aluminum Yes
Weight
Weight without packaging 6kg
6AV7862-2TA00-1AA0
SCD 1900
ST80_2013_EN_Kap05.book Seite 136 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Industrial monitors and thin clients
SCD monitors 1900
5/137
Siemens ST 80 / ST PC · 2013
Ordering data
Order No.
Dimensional drawings
All dimensions in mm. For mounting cut-out see technical speci-
fications.
SCD 1900
SCD monitor 1900 6AV7862-2TA00-1AA0
Portrait SCD monitor 1900 6AV7466-2TA17-1AA0
Accessories
Cable for connecting to
the graphics interface of the PC
VGA cable 3.0 m 6AV7860-0AH30-0AA0
VGA cable 5.0 m 6AV7860-0AH50-0AA0
DVI-D cable, 3.0 m 6AV7860-0BH30-0AA0
DVI-D cable, 5.0 m 6AV7860-0BH50-0AA0
USB cable for connecting the
touch screen
3.0 m 6AV7860-0CH30-0AA0
5.0 m 6AV7860-0CH50-0AA0
External power supply
for SCD 1900 6AV7860-2AD06-0AA0
100-230 V AC, 50-60 Hz; incl.
mounting accessories for optional
installation at the device.
W+1 (cutout)
H+1 (cutout)
G_ST80_XX_00239
S
310
483
ST80_2013_EN_Kap05.book Seite 137 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Industrial monitors and thin clients
SCD monitors 1900
5/138 Siemens ST 80 / ST PC · 2013
Dimensional drawings (continued)
5
All dimensions in mm. For mounting cut-out see technical specifications.
More information
Additional information is available in the Internet under:
http://www.siemens.com/industrial-lcd
1
1
1
1
18.5 18.5
23.3
57.7133.6
62.5 136.5
114.4
105.1
with installed optional DC power supply unit
G_ST80_XX_00429
11
483
310
11
6
43
81
63
67
USB-Touch VGA
DVI
Power
24V...
ST80_2013_EN_Kap05.book Seite 138 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Industrial monitors and thin clients
SIMATIC Industrial Thin Client
5/139
Siemens ST 80 / ST PC · 2013
Overview
SIMATIC ITC Industrial Thin Clients are powerful operating units
for flexible use in distributed visualization applications. All
devices are equipped with high-resolution, brilliant widescreen
displays, and due to the diverse communication protocols they
can be used both for challenging machine-level operator control
& monitoring and for the connection to control systems, e.g. in
the SCADA environment. They can be used as (additional)
operator stations on a SIMATIC Industrial PC, Panel PC, or
server, and on a SIMATIC Panel.
The following installation versions are available:
SIMATIC ITC1200 – 12" Touch
SIMATIC ITC1500 – 15" Touch
SIMATIC ITC1900 – 19" Touch
SIMATIC ITC2200 – 22" Touch
In addition to these devices, we continue to offer the SIMATIC
Thin Client 10", SIMATIC Thin Client 15", and SIMATIC Thin Client
PRO 15" for solutions in 4:3 format. These differ technically from
the SIMATIC ITC. For more details, refer to the SIMATIC Thin
Client chapter.
The SIMATIC HMI Thin Client Ex is available for hazardous
areas. This device differs technically from the devices
mentioned above. For more details, refer to the SIMATIC Thin
Client EX chapter.
Technical specifications
6AV6 646-1AA22-0AX0 6AV6 646-1AB22-0AX0 6AV6 646-1AC22-0AX0 6AV6 646-1AD22-0AX0
Display
Screen diagonal 12.1 in 15.4 in 18.5 in 21.5 in
Display width 261.1 mm 331.2 mm 409.8 mm 495.6 mm
Display height 163.2 mm 207 mm 230.4 mm 292.2 mm
Type TFT widescreen display,
LED backlighting TFT widescreen display,
LED backlighting TFT widescreen display,
LED backlighting TFT widescreen display,
LED backlighting
Number of colors 16 777 200 16 777 200 16 777 200 16 777 200
Resolution (pixels)
• Horizontal image resolution 1 280 1 280 1 366 1 920
Vertical image resolution 800 800 768 1 080
General features
PDF reader Yes Yes Yes Yes
Backlighting
• Backlighting (type) LED, dimmable LED, dimmable LED, dimmable LED, dimmable
Dimmable backlight Yes; 5-100 % Yes; 5-100 % Yes; 5-100 % Yes; 5-100 %
Control elements
Mouse/cursor control
•USB Yes Yes Yes Yes
Keyboard fonts
• external keyboard
-USB Yes Yes Yes Yes
Touch operation
• Design as touch screen Yes Yes Yes Yes
- Analog, resistive Yes Yes Yes Yes
Touch keyboard Yes Yes Yes Yes
Installation type/mounting
Built-in unit Yes Yes Yes Yes
ST80_2013_EN_Kap05.book Seite 139 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Industrial monitors and thin clients
SIMATIC Industrial Thin Client
5/140 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
5
Supply voltage
Type of actuation 24 V DC 24 V DC 24 V DC 24 V DC
permissible range, lower limit (DC) 19.2 V 19.2 V 19.2 V 19.2 V
permissible range, upper limit (DC) 28.8 V 28.8 V 28.8 V 28.8 V
Input current
Current consumption 1.2 A 1.5 A 1.3 A 2.2 A
Inrush current A²s 0.5 A²·s 0.5 A²·s 0.5 A²·s 0.5 A²·s
Interfaces
USB on the rear 2222
USB at the front 0000
Industrial Ethernet
• Transmission rate, max. 1 000 Mbit/s 1 000 Mbit/s 1 000 Mbit/s 1 000 Mbit/s
Number of industrial Ethernet
interfaces 1111
Protocols
Protocols (Ethernet)
•TCP/IP Yes Yes Yes Yes
• DHCP Yes Yes Yes Yes
•SNMP Yes Yes Yes Yes
• DCP Yes Yes Yes Yes
• LLDP Yes Yes Yes Yes
WEB characteristics
• HTTP Yes Yes Yes Yes
•HTML Yes; HTML5 Yes; HTML5 Yes; HTML5 Yes; HTML5
•XML Yes Yes Yes Yes
•CSS Yes Yes Yes Yes
• JavaScript Yes Yes Yes Yes
Protocols (terminal link)
•Sm@rtServer Yes Yes Yes Yes
•RDP Yes Yes Yes Yes
• VNC viewer Yes Yes Yes Yes
• Citrix No No No No
• SINUMERIK Yes Yes Yes No
Protocols
PROFINET IO Device
• Services
- PROFIenergy No No No No
Degree and class of protection
IP65 at front Yes Yes Yes Yes
IP20 rear Yes Yes Yes Yes
Standards, approvals, certificates
CE Yes Yes Yes Yes
KC approval Yes Yes Yes Yes
cULus Yes Yes Yes Yes
C-TICK Yes Yes Yes Yes
Use in hazardous areas
cULus Class I Zone 1 No No No No
cULus Class I Zone 2, Division 2 Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon
• FM Class I Division 2 Yes; Available soon Yes; Available soon Yes; Available soon Yes; Available soon
6AV6 646-1AA22-0AX0 6AV6 646-1AB22-0AX0 6AV6 646-1AC22-0AX0 6AV6 646-1AD22-0AX0
ST80_2013_EN_Kap05.book Seite 140 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Industrial monitors and thin clients
SIMATIC Industrial Thin Client
5/141
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
Ambient conditions
Min. ambient temperature C 0°C 0°C 0°C
Max. ambient temperature 50 °C 50 °C 45 °C 45 °C
Storage/transport temperature
•Min. -20 °C -20 °C -20 °C -20 °C
•max. 60 °C 60 °C 60 °C 60 °C
Relative humidity
Relative humidity during operation 90 % 90 % 90 % 90 %
Software
Web browser Yes Yes Yes Yes
Configuration
• On-board Yes Yes Yes Yes
Remote administration Yes; With Remote
Configuration Center (RCC)
as of V2.0
Yes; With Remote
Configuration Center (RCC)
as of V2.0
Yes; With Remote
Configuration Center (RCC)
as of V2.0
Yes; With Remote
Configuration Center (RCC)
as of V2.0
Languages
Online languages
•German Yes Yes Yes Yes
• English Yes Yes Yes Yes
I/O
I/O devices
USB memory Yes; USB storage media
can be connected Yes; USB storage media
can be connected Yes; USB storage media
can be connected Yes; USB storage media
can be connected
Mechanics/material
Type of housing (front)
• Aluminum Yes Yes Yes Yes
Dimensions
External dimensions (W x H x D)
•Width 330 mm 415 mm 483 mm 560 mm
•Height 241 mm 310 mm 337 mm 380 mm
Mounting cutout (W x H x D)
•Width 310 mm 396 mm 465 mm 542 mm
•Height 221 mm 291 mm 319 mm 362 mm
•Depth 82 mm 75 mm 75 mm 75 mm
Weight
Weight without packaging 3.4 kg 5.2 kg 6.5 kg 7.1 kg
Weight incl. packaging 4.1 kg 5.7 kg 7.1 kg 7.8 kg
6AV6 646-1AA22-0AX0 6AV6 646-1AB22-0AX0 6AV6 646-1AC22-0AX0 6AV6 646-1AD22-0AX0
ST80_2013_EN_Kap05.book Seite 141 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Industrial monitors and thin clients
SIMATIC Industrial Thin Client
5/142 Siemens ST 80 / ST PC · 2013
5
Ordering data
Order No.
Dimensional drawings
All dimensions in mm. For mounting cut-out see technical
specifications.
Mounting dimensions
More information
Additional information is available on the Internet at:
http://www.siemens.com/simatic-itc
Industrial Thin Client
SIMATIC ITC1200
12" Touch device 6AV6646-1AA22-0AX0
SIMATIC ITC1500
15" Touch device 6AV6646-1AB22-0AX0
SIMATIC ITC1900
19" Touch device 6AV6646-1AC22-0AX0
SIMATIC ITC2200
22" Touch device 6AV6646-1AD22-0AX0
Accessories See HMI accessories,
from page 2/96
Industrial
Thin Client Faceplate Dimen-
sions, in mm Mounting Cutout,
in mm
W H W+1 H+1 D
ITC1200 330 241 310 221 82
ITC1500 415 310 396 291 75
ITC1900 483 337 465 319 75
ITC2200 560 380 542 362 75
H
W
W+1
H+1
6.5D
G_ST80_XX_00522
ST80_2013_EN_Kap05.book Seite 142 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Industrial monitors and thin clients
SIMATIC Thin Client
5/143
Siemens ST 80 / ST PC · 2013
Overview
SIMATIC Thin Clients are very economical operator panels
which can be used flexibly in various distributed applications.
They can be used as (additional) operator stations on a
SIMATIC industrial PC or also on a SIMATIC Panel.
The following versions are available:
The rack-mounting versions SIMATIC Thin Client 10" Touch
and SIMATIC Thin Client 15" Touch
The support arm version SIMATIC Thin Client PRO 15" Touch
with a rugged and very compact aluminum enclosure which is
completely IP65 protected
The new high-performance SIMATIC ITC Industrial Thin Clients
with high-resolution touch displays in widescreen format from
12" to 22" are available for demanding terminal applications.
There are technical differences to the SIMATIC Thin Client.
For more information, see SIMATIC Industrial Thin Client.
The SIMATIC HMI Thin Client Ex is available for hazardous
areas. This device differs technically from the devices
mentioned above.
Technical specifications
6AV6646-0AA21-2AX0 6AV6646-0AB21-2AX0
10" Touch 15" Touch
Display
Size 10.4" 15.1"
Display type TFT, 65536 colors TFT, 65536 colors
Resolution (pixels)
Resolution (WxH in pixel) 640 x 480 1024 x 768
Backlighting
• MTBF backlighting (at 25 °C) about 50000 hours about 50000 hours
Control elements
Control elements Touch screen Touch screen
Connection for mouse/keyboard/
barcode reader USB / USB USB / USB
Touch operation
Touch screen Analog, resistive Analog, resistive
Supply voltage
Supply voltage 24 V DC 24 V DC
Processor
Processor ARM, 266 MHz ARM, 266 MHz
Memory
Type Flash / RAM Flash / RAM
Interfaces
Interfaces 1 x Ethernet (RJ45) 1 x Ethernet (RJ45)
USB port 1 x USB 1 x USB
Industrial Ethernet
Industrial Ethernet interface 1 x Ethernet (RJ45) 1 x Ethernet (RJ45)
ST80_2013_EN_Kap05.book Seite 143 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Industrial monitors and thin clients
SIMATIC Thin Client
5/144 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
5
Ordering data
Order No. Order No.
Protocols
WEB characteristics
• HTTP Yes Yes
•HTML Yes Yes
•XML Yes Yes
•CSS Yes Yes
• JavaScript Yes Yes
Protocols (terminal link)
•Sm@rtServer Yes Yes
•RDP Yes Yes
EMC
Emission of radio interference
acc. to EN 55 011
• Emission of radio interferences
acc. to EN 55 011 (limit class A) Yes; EN 61000-6-4, interference emission:
Intended for use in industrial areas.
Degree and class of protection
Front IP54, NEMA 12, (when installed) IP54, NEMA 12, (when installed)
Rear IP20 IP20
Standards, approvals, certificates
Certifications CE, cULus, C-TICK, NEMA 12 (when installed: IP54,
enclosure type 12; optional IP65, enclosure
type 4X/type 12 (6AV6671-6AP00-0AX0))
CE, cULus, C-TICK, NEMA 12 (when installed: IP54,
enclosure type 12; optional IP65, enclosure type
4X/type 12 (6AV6671-6AP00-0AX0))
EMC The product is designed for use in industrial environ-
ments. When used in residential areas, the emission of
radio interference according to limit class B of EN 55011
must be ensured. For further information please refer to
the user documentation.
The product is designed for use in industrial environ-
ments. When used in residential areas, the emission of
radio interference according to limit class B of EN 55011
must be ensured. For further information please refer to
the user documentation.
Suitable for safety functions No No
Ambient conditions
maximum permissible angle of
inclination without external ventilation +/- 35 ° +/- 35 °
Storage/transport temperature
• Transport, storage -20 °C to +60 °C -20 °C to +60 °C
Relative humidity
• max. relative humidity 85 %; (Storage)
Dimensions
Front of enclosure (W x H) 325 mm x 263 mm 400 mm x 310 mm
Weight
Weight 2.2 kg 3.6 kg
6AV6646-0AA21-2AX0 6AV6646-0AB21-2AX0
10" Touch 15" Touch
SIMATIC Thin Client
10" Touch device 6AV6646-0AA21-2AX0
15" Touch device 6AV6646-0AB21-2AX0
Starter kits
SIMATIC Thin Client
with Sm@rtAccess
(License to operate
SmartAccess on the server)
Touch device 10" with
Sm@rtAccess license (panels) 6AV6653-6AA01-2AA0
Touch device 15" with
Sm@rtAccess license (panels) 6AV6653-6BA01-2AA0
Touch device 15"PRO with
Sm@rtAccess license (panels) 6AV6653-6CA01-2AA0
Touch device 10" with
Sm@rtAccess license for
WinCC flexible 2008 Runtime
6AV6653-6DA01-2AA0
Touch device 15" with
Sm@rtAccess license for
WinCC flexible 2008 Runtime
6AV6653-6EA01-2AA0
Touch device 15" PRO with
Sm@rtAccess license for
WinCC flexible 2008 Runtime
6AV6653-6FA01-2AA0
Option packages
IP65 set
(upgrade from IP54 to IP65) 6AV6671-6AP00-0AX0
Accessories See HMI accessories,
from page 2/96
ST80_2013_EN_Kap05.book Seite 144 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Industrial monitors and thin clients
SIMATIC Thin Client
5/145
Siemens ST 80 / ST PC · 2013
Dimensional drawings
All dimensions in mm. Tolerance ± 1 mm.
SIMATIC Thin Client 10" Touch SIMATIC Thin Client 15" Touch
More information
Additional information is available in the Internet under:
http://www.siemens.com/simatic-thin-client
309
232.49
275
335
247
113.59
106.71
59.9
30
6.2
G_ST80_XX_00305
400
310
59.9 6.2
113.59
63.21
288
30
232.49
366
G_ST80_XX_00306
ST80_2013_EN_Kap05.book Seite 145 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
RMOS3 real-time operating system
RMOS3 real-time operating system
5/146 Siemens ST 80 / ST PC · 2013
5
Overview
SICOMP RMOS3
RMOS3 is a real-time and multitasking-capable operating
system. In addition to real-time capability, which ensures fast
response times, deterministic behavior is also an important
feature. This guarantees response times within a short time
interval.
Rugged operating systems guarantee reliable behavior even
under exceptional circumstances. RMOS3 has been optimized
for use in embedded applications. In harsh environments, the
rugged memory cards or CompactFlash memories can be used
instead of hard disks. In addition, RMOS3 is suitable for
operation with or without an operator.
RMOS3 V3.50 Real-Time Operating System
With the RMOS3 V3.50, Intel Core i processors with up to
2 cores/4 threads are now also supported. The "Symmetric
Multicore Processing" (SMP) mode makes it possible to
implement complex applications that are simultaneously
processed on multiple processor cores. RMOS3 V3.50 ensures
that the cores are symmetrically utilized so that a performance
increase of up to 100% can be achieved on the SIMATIC IPC
with 2 processors.
The new RMOS3 real-time operating system is characterized by
increased security thanks to memory protection, minimum
interrupt response times and fast hard disk access. For SIMATIC
IPCs, automation solutions based on C/C++ with demands for
hard real time, deterministic response and high performance
can now be created more easily, conveniently and with greater
stability.
RMOS3-GNU V3.0
The RMOS3-GNU software package uses generally available
Linux tools with which users can easily create real-time applica-
tions for RMOS3 on the SIMATIC IPC.
The GNU-based software tools for Windows XP/Vista/Windows 7
computers comprise the assemblers, C/C++ compilers, linkers
and debuggers familiar in the Linux environment as well as the
Eclipse development interface. The integrated cross debugger
is useful for commissioning the customer application since the
development and target system can be connected via TCP/IP.
C/C++ header files and libraries are available for applications
which use RMOS3 Version 3.30 or higher.
RMOS3-TCP/IP V3.0
The RMOS3-TCP/IP V3.0 software package offers the appli-
cation developer a wide range of options for implementing TCP/
UDP-based communication tasks running under the real-time
operating system RMOS3, V3.40 or higher.
Apart from the usual UDP and TCP protocols for application
development, the new version of RMOS3-TCP/IP not only
provides Address Resolution Protocol (ARP), Multicast and
ICMP services (Ping), but also client services for the DHCP
(Dynamic Host Configuration Protocol), DNS (Domain Name
System), NTP (Network Time Protocol) and SMTP (Simple Mail
Transfer Protocol).
Together with the FTP programming interface and the Web
server with process data connection, the programmer obtains
numerous programming interfaces for even greater flexibility in
communication.
RMOS3-GRAPHX V1.0
With the RMOS3-GRAPHX product, window-based, graphical
user interfaces can be implemented with the RMOS3 real-time
operating system Version V3.30 or higher.
Extensive graphical libraries increase the user-friendliness of the
system and support cost savings due to centralization of the
control and operation on a CPU.
With a Graphical User Interface (GUI), familiar from Windows,
window displays can be implemented with the familiar command
elements in the form of buttons, toolbars, scrollbars, selection
lists and symbols as well as dialog boxes for prompts or inputs.
BSP SIMATIC IPC V4.0 for RMOS3
The Board Support Package BSP SIMATIC IPC V4.0 for
RMOS3 is a software package for supporting all interfaces
(e.g. PROFINET onboard) and other onboard functions
(e.g. battery monitoring, watchdog) for the following industrial
PCs: SIMATIC IPC227D, SIMATIC IPC427C, SIMATIC IPC627C,
SIMATIC IPC 827C, SIMATIC IPC647C and SIMATIC IPC847C.
ST80_2013_EN_Kap05.book Seite 146 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
RMOS3 real-time operating system
RMOS3 V3.50 real-time operating system
5/147
Siemens ST 80 / ST PC · 2013
Overview
RMOS3 is the real-time and multitasking-capable operating
system from Siemens for implementing your automation solution
with the programming languages C and C++. In mechanical
engineering or in the manufacture of machine tools RMOS3 is
used in test beds, packaging or printing machines where high
response times in conjunction with open and closed-loop control
tasks are required.
The new RMOS3 real-time operating system is characterized by
increased security thanks to memory protection, minimum
interrupt response times and fast hard disk access.
Furthermore, with the RMOS3 V3.50 version, Intel Core i
processors with up to 2 cores/4 threads are now also supported.
The "Symmetric Multicore Processing" (SMP) mode makes it
possible to implement complex applications that are simultane-
ously processed on multiple processor cores. RMOS3 V3.50
ensures that the cores are symmetrically utilized so that a perfor-
mance increase of up to 100% can be achieved on the
SIMATIC IPC with 2 cores.
For SIMATIC IPC, automation solutions based on C/C++ with
demands for hard real time, deterministic response and high
performance can now be created more easily, conveniently and
with greater stability.
RMOS3 has been optimized for use on PC platforms in
embedded systems and fulfills industrial requirements with
respect to:
Real-time and multitasking capability
Deterministic features
• Ruggedness
Scalability/memory requirements
Operation with or without an operator
Modern development tools
Quality assurance
Warranty conditions
Service & Support
Technical specifications
System requirements for the development system
PC with Windows XP, Windows Vista or Windows 7
Required software components:
RMOS3 development environment as of RMOS3 V3.40
RMOS3-GNU as of V2.1, compiler and development interface
Board Support Packages
(optional, module-specific expansion packages)
System requirements for target system
SIMATIC IPC427C
SIMATIC Box PC 627B/827B, IPC627C
SIMATIC Rack PC 647B/847B, IPC647C, IPC847C
Required software components:
RMOS3 V3.50 runtime environment
(RMOS nucleus and service programs)
Board Support Packages (optional, module-specific drivers)
Product structure, listed acc. to development and
runtime licenses
1)
Optional Board Support Packages (BSP)
Product name Description
RMOS3 V3.50 EL Single license for RMOS3
development environment
incl. a RMOS3 runtime license
comprising
Sources and libraries for
application creation
RMOS3 runtime environment incl.
loadable programs and TCP/IP
stack and 10/100 Mbit/s LAN
drivers
Configurable RMOS3 Nucleus for
the Use on SIMATIC IPCs
Examples and documentation
RMOS3 V3.50 EL Update
RMOS3-GNU V3.0 EL Single license for the GNU
development tools incl.
Compiler, linker, debugger
and Eclipse IDE
• Special RMOS3 libraries for
application creation
Example projects and
documentation
RMOS3-GNU V3.0 EL Update
BSP-SIMATIC IPC 4.0 EL
1)
Single license for IPC227D,
IPC427C, IPC627C, IPC827C,
IPC647C, IPC847C incl. runtime
license for BSP (no runtime license
for RMOS3 V3.50):
Configurable nucleus
• Driver for
USB, LAN, PROFINET IO,
PROFIBUS DP, BasicCAN
GNU example projects and docu-
mentation
BSP SIMATIC IPC V4.0 EL Update
1)
RMOS3-TCP/IP V3.0 EL
1)
incl. German documentation Master license for
TCP/IP communication
Application development with
socket interface
Programming interface for FTP
RMOS3-TCP/IP V3.0 EL Update
1)
RMOS3-PC IO V2.0 Free download as programming
example with programming inter-
face for access to PC I/O modules
ST80_2013_EN_Kap05.book Seite 147 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
RMOS3 real-time operating system
RMOS3 V3.50 real-time operating system
5/148 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
5
Product structure – Runtime licenses
Supported boot media
•Disk
•Hard disk
IDE flash disk
LAN (on request)
1)
Optional Board Support Packages (BSP)
Product name Description
RMOS3 V3.50 RT Single RMOS3 V3.50 runtime
license
RMOS3-TCP/IP V3.x RT
1)
• Single RMOS3 TCP/IP runtime
license
Required for application programs
with socket interface
RMOS3-CANopen168
1)
Single runtime license with software
package when the CPCI-COM168
module is used in networks with
CANopen
BSP SIMATIC IPC RT V4.x
1)
Single runtime license for BSP
Available drivers for
RMOS3 V3.50
The drivers described below are currently available for RMOS3 V3.50
Keyboard PS2 keyboard
USB keyboard
1)
Serial, parallel Universal I/O driver (BYT driver) for
character-oriented I/O devices
• COM driver for 3964(R) protocol
Transmission mode and baud rate
configurable
Graphics • EGA (text mode)
• Semi-graphical interface
(function library on request)
RMOS3-GRAPHX (graphics library
for pixel graphics window
displays)
1)
Ethernet 10/100/1000 Mbit/s LAN driver:
IPC227D, IPC427C, IPC627C,
IPC827C, IPC647C, IPC847C
Filter functionality, configurable
transfer rates and transfer modes
USB
1)
• Optional USB driver for USB 1.1
protocol and USB 2.0 protocol
Support for keyboard, mouse,
hub, memory stick and CD-ROM
(on request)
PROFINET IO Module driver for operating the
CP 1616-compatible PROFINET
components (CP 1616, CP 1604,
SIMATIC IPC with PROFINET
onboard)
• Supports the ERTEC 400 control-
ler, RT and IRT, IO Controller and/or
IO Device
PROFIBUS DP
1)
Module driver and programming
interface for SIMATIC PC with
PROFIBUS onboard, CP5611 com-
patible, DPV0 master and/or slave
CAN
1)
BasicCAN driver for connection to
CAN bus
• Supports the SJA1000 CAN
controller on SIMATIC IPC427C
Ordering data
Order No.
RMOS3 V3.50 EL 6AR1405-0EA00-1AA4
Single license for RMOS3 develop-
ment environment incl. a RMOS3
runtime license
RMOS3 V3.50 EL Update 6AR1405-0EA50-1AA4
Update from V3.40 to V3.50. Single
license for RMOS3 development
environment incl. a RMOS3 runtime
license
RMOS3 V3.50 RT 6AR1403-0DA3
Single RMOS3 V3.50 runtime
license
ST80_2013_EN_Kap05.book Seite 148 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
RMOS3 real-time operating system
RMOS3-GNU V3.0
5/149
Siemens ST 80 / ST PC · 2013
Overview
RMOS3-GNU V3.0 is a software package that supports devel-
opment and testing of applications for the real-time operating
system RMOS3 (Version 3.40 and higher).
It builds on a GNU-based tool chain that is well-known and
widely implemented in the Linux environment and contains the
expansions required for RMOS3.
RMOS3-GNU V3.0 replaces the existing RMOS3-GNU V2.x
product. An update from RMOS3-GNU V2.x to Version V3.0 is
available.
RMOS3-GNU V3.0 contains the following new functions:
Up-to-date versions of the GNU tool chain,
e.g. C/C++ compiler V3.4.1
Updated versions of Eclipse V3.4 and CDT plug-in V5.0.
New Eclipse "terminal" plug-in for remote operation of the
target system
New Eclipse "profiling" plug-in for determining the system load
and the task activity on the target system
Extended Eclipse "remote launcher" plug-in for testing the
applications on Privilege Level 0 or alternatively on Privilege
Level 1
Technical specifications
System requirements: Development system
Windows XP, Windows Vista, or Windows 7
Java Runtime Environment, Version 1.5 and higher
(only necessary when using Eclipse IDE)
RMOS3 development environment RMOS3 Version 3.40
(incl. software fix RMOS3 V3.40.02) or RMOS3 V3.50
(incl. software fix RMOS3 V3.50.04)
System requirements: Target system
RMOS3 version 3.40.02 and higher or version 3.50.04
(configurable nucleus V3.30.06 R01)
Licenses
The GNU-based tool chain is subject to the GNU GENERAL
PUBLIC LICENSE (GPL) or
the GNU LESSER GENERAL PUBLIC LICENSE (LGPL).
Please read the licensing rules supplied with the product.
Ordering data
Order No.
SICOMP RMOS3-GNU V3.0 EL 6AR1405-0BA00-1CA0
Single license for the GNU develop-
ment tools incl. compiler, linker,
debugger and Eclipse IDE,
special RMOS3 libraries for creating
applications, project examples and
documentation
SICOMP RMOS3-GNU V3.0 EL
update 6AR1405-0BA50-1CA0
Update V2.x to V3.0, development
package, single license, CD-ROM,
including description in German in
PDF format
ST80_2013_EN_Kap05.book Seite 149 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
RMOS3 real-time operating system
RMOS3-TCP/IP V3.0
5/150 Siemens ST 80 / ST PC · 2013
5
Overview
The RMOS3-TCP/IP V3.0 software package provides libraries for
the quick and easy generation of TCP/IP, FTP and Web applica-
tions. In addition, the software package offers FTP and Telnet
services for the exchange of files and for the remote mainte-
nance of the RMOS3 system. New additions are the DHCP, DNS,
NTP and SMTP services for even greater flexibility in communi-
cation.
Technical specifications
System requirements for the development system
PC with Windows XP, Windows Vista or Windows 7
Required software components:
RMOS3 development environment as of RMOS3 V3.40
RMOS3-GNU as of V2.1, compiler and development interface
Board support packages
(optional, module-specific expansion packages)
System requirements for target system
SIMATIC Microbox PC IPC427C
SIMATIC Box PC 627B/IPC627C
SIMATIC Box PC 827B
SIMATIC Rack PC 647B/IPC647C
SIMATIC Rack PC 847B/IPC847C
Required software components:
RMOS3 V3.40 or higher runtime environment
(RMOS nucleus and service programs)
Board support packages (optional, module-specific drivers)
Ordering data
Order No.
SICOMP RMOS3-TCP/IP V3.0 EL 6AR1403-0AN00-1BA0
Development package, single
license, TCP/IP software for RMOS3
V3.40 or higher, CD-ROM, including
description in German in PDF format
SICOMP RMOS3-TCP/IP V3.0 EL,
update from V2.3 to V3.0 6AR1403-0AN50-1BA0
Development package, single
license, TCP/IP software for RMOS3
V3.40 or higher, CD-ROM, including
description in German in PDF format
SICOMP RMOS3-TCP/IP V3.x
Runtime license 6AR1403-0BN3
Runtime license for TCP/IP software
V3.0 or higher for use with RMOS3
V3.40 or higher
ST80_2013_EN_Kap05.book Seite 150 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
RMOS3 real-time operating system
RMOS3-GRAPHX V1.0
5/151
Siemens ST 80 / ST PC · 2013
Overview
RMOS3-GRAPHX V1.0 provides you with a comprehensive
graphics package which enables you to expand your C/C++
based automation solution under SICOMP RMOS3 with a user-
friendly graphics interface for operator control and monitoring.
Use of the Qt-based graphics library of the Norwegian company
Trolltech-Nokia (www.gt.nokia.com) allows window-based inter-
faces to be created with a "look and feel" and input facilities
comparable to Windows. Real-time characteristics are
maintained within the multi-tasking RMOS3 operating system
environment.
In combination with the widely used development tools GNU,
Eclipse and the QT Designer from Trolltech-Nokia, convenient
development tools are available to you for creating your real-time
applications on approved SIMATIC IPC hardware.
Technical specifications
System requirements for the development system
PC with Windows XP, Windows Vista or Windows 7
Required software components:
RMOS3 development enviroment RMOS3 V3.40 or higher or
RMOS3 V3.30 including software fix RMOS3 V3.30.04
RMOS3-GNU as of V2.1, compiler and development interface
For RMOS3-GNU V3.0 or higher, an update for
RMOS3-GraphX V1.1 is offered via Customer Support:
http://www.siemens.com/automation/support-request
RMOS3-GRAPHX V1.0, graphics package for creation of
graphics interfaces for RMOS3
Update RMOS3-GraphX V1.1 in connection with RMOS3-GNU
V3.0 or higher is available via Customer Support:
http://www.siemens.com/automation/support-request
Qt Desktop Light Edition for Windows from Trolltech-Nokia
(www.gt.nokia.com)
Optional:
Board support packages
(optional, module-specific expansion packages)
System requirements for target system
SIMATIC IPC
Required software components:
RMOS3 V3.40 or higher runtime environment
(RMOS nucleus and service programs)
RMOS3-GRAPHX V1.0 runtime license
(graphics support, USB driver)
Optional:
Board support packages
(optional, module-specific drivers)
Ordering data
Order No.
RMOS3-GRAPHX V1.0 EL 6AR1403-0BG00-1AA0
Master license for graphic library for
the creation of window-oriented
interfaces of RMOS3 Version 3.30
and higher
Qt Desktop Light Edition
Single Platform Windows
development package
Obtainable from
Trolltech-Nokia,
www.gt.nokia.com
Qt Desktop Light Edition V4.1.4 for
Windows, incl. Qt Designer
ST80_2013_EN_Kap05.book Seite 151 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
RMOS3 real-time operating system
BSP SIMATIC IPC V4.0 for RMOS3
5/152 Siemens ST 80 / ST PC · 2013
5
Overview
The Board Support Package BSP SIMATIC IPC V4.0 supports
SIMATIC IPC devices of the C generation and the D generation
starting with the NANOBOX PC IPC227D. The following SIMATIC
IPCs can therefore now be operated along with their PROFINET
onboard functionality, PROFIBUS, CAN, and hardware-based
functions with the real time operating system RMOS3 V3.50 and
higher:
IPC227D
IPC427C and IPC427D
IPC627C and IPC827C
IPC647C and IPC847C
Technical specifications
System requirements for the development system
PC with Windows XP, Windows Vista or Windows 7
Required software components:
RMOS3 development environment as of RMOS3 V3.50
RMOS3-GNU V3.0 and higher, compiler and development
interface
Board Support Packages
(optional, module-specific expansion packages)
System requirements for target system
SIMATIC IPC227D
SIMATIC IPC427C and IPC427D
SIMATIC IPC627C and IPC827C
SIMATIC IPC647C and IPC847C
Required software components:
RMOS3 V3.50 or higher runtime environment
(RMOS nucleus and service programs)
Board Support Packages
(optional, module-specific drivers)
Ordering data
Order No.
BSP SIMATIC IPC V4.0 EL 6AR1403-0BC00-1DA0
Board Support Package for
SIMATIC IPC227D,
SIMATIC IPC427C,
SIMATIC IPC627C, IPC827C,
SIMATIC IPC647C, and IPC847C
for use with the SICOMP RMOS3
operating system V3.50 and higher,
development package,
single license, runtime license,
CD-ROM, including description in
German in PDF format,
RMOS3 runtime license V3.50 and
higher not included.
BSP SIMATIC IPC V4.0 EL Update 6AR1403-0BC50-1DA0
Update from BSP SIMATIC IPC V3.1
to BSP SIMATIC IPC V4.0
BSP Nanobox IPC V1.x RT
Package 6AR1403-1DC3
License bundle comprising RMOS3
V3.50 RT, RMOS3-TCP/IP V3.x RT
and BSP SIMATIC IPC V4.x RT
runtime licenses for use with the
Nanobox PC IPC227D.
BSP SIMATIC IPC V4.x RT 6AR1403-0DC3
Runtime license for Board Support
Package BSP SIMATIC IPC V4.0 EL
for
• SIMATIC IPC227D
• SIMATIC IPC427C
• SIMATIC IPC627C, IPC827C
• SIMATIC IPC647C, IPC847C for
use with the SICOMP RMOS3
operating system V3.50 and higher
ST80_2013_EN_Kap05.book Seite 152 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Expansion components and accessories
Expansion components / accessories
5/153
Siemens ST 80 / ST PC · 2013
Overview
SIMATIC PCs offer users a wide range of designs and systems
which perfectly match industrial applications and fulfill the high
requirements in terms of ruggedness.
These include e.g.:
Wide temperature of use up to 55 °C
High resistance to vibration/shock
Rugged housing design
Special degrees of protection up to IP65, NEMA 4
High electromagnetic compatibility (EMC)
UL, CE industry certification
Integral industrial power supplies (NAMUR)
Easy-to-service design for rapid replacement of faulty
components
Increased system availability
A graded concept is available for effective early detection of
potential failures and minimization of actual downtimes. This
consists of hardware and software expansion options specially
developed for SIMATIC PCs with which the system availability
can be individually increased depending on the safety require-
ments.
The use pays off:
Because the safety is significantly increased by components
such as a second hard disk for additional data backup or the
DiagMonitor for permanent self-diagnostics. The system avail-
ability options thus make a contribution to the significant minimi-
zation of the total costs (TCO) of the installation according to the
motto: "Small effort, large effect".
The following components are available:
Hard disks options
Solid-state drive (SSD)
Second hard disk:
The safety of the data stored on the hard disk is a cornerstone
for system availability.
- Simple and fast data backup of complete installation and
user data in combination with the SIMATIC IPC Image &
Partition Creator.
- Following a faulty software installation or in the case of a hard
disk defect, the system can be immediately put back into
operation by booting the back-up disk.
- Fast download of the last saved hard disk image to the
working disk.
Two hard disks are optionally available in a user-friendly swap
frame for the Rack PC to permit fast and easy data backup.
SIMATIC IPC CompactFlash/SIMATIC IPC CFast
The application of PCs in industrial areas requires rugged
systems to prevent or minimize production downtimes. SIMATIC
IPCs have been developed precisely for this purpose. One way
of improving the industrial suitability and system availability of
SIMATIC IPCs even further is to use SIMATIC PC CompactFlash
cards instead of hard disk drives. These are system-tested with
the SIMATIC IPCs.
SIMATIC PC CompactFlash is a hardware option that can be
ordered via the relevant SIMATIC IPC configurator or separately
as an accessory.
The SIMATIC IPC CFast memory cards are readily replaceable
mass storage units for SIMATIC IPC427D and IPC477D. They
are connected via a SATA interface.
As a result of the different interface, the SIMATIC IPC CFast
memory cards are not compatible with the SIMATIC IPC
CompactFlash memory cards.
SIMATIC IPC USB FlashDrive
Mobile memory medium for SIMATIC IPC/PG
Fast data transfer (USB 2.0) and high memory capacity
Ultra-compact and rugged
Preinstalled SIMATIC IPC BIOS Manager
SIMATIC IPC Service USB FlashDrive
The SIMATIC IPC Service USB FlashDrive is the ideal tool for
maintenance as well as saving and restoring of data. With the
preinstalled SIMATIC IPC Image & Partition Creator and
SIMATIC IPC BIOS Manager, the FlashDrive is immediately
ready for use.
Central I/O expansion PC IO
The PC IO expansion comprises:
Basic module with encoder/counter functionality, PCI104
interface to the host system, and communication interfaces to
the I/O modules
Digital and analog I/O modules that are managed by the basic
module
Mechanical installation components
Industrial USB Hub 4 (see HMI accessories, page 2/96)
The Industrial USB Hub 4 is essentially used as a USB hub for
the connection of I/O devices to Multi Panels and Panel PCs
with an integral USB interface
USB I/O devices can be connected to the panel and operated
via the USB Hub 4 without opening the cabinet door
The Industrial Hub 4, in contrast to commercially available
USB hubs, can be used in harsh industrial environments
(IP65)
SIMATIC Panel PC Remote Kit
Separation of computer unit and operator control unit
At a maximum distance of up to 30 m
Pure hardware solution, no need to install additional software
Maintaining the full Panel PC front functionality
ST80_2013_EN_Kap05.book Seite 153 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Expansion components and accessories
Expansion components / accessories
5/154 Siemens ST 80 / ST PC · 2013
Overview (continued)
5
SIMATIC IPC Image & Partition Creator
Software tool for preventive data backup of hard disk contents
High-speed restoring of system and data partitions with bit
accuracy; user software and special installations are also
backed up
Software tool for editing the hard disk partitioning
SIMATIC IPC DiagMonitor
Diagnostic and alarm software for monitoring SIMATIC IPCs
Comprehensive monitoring of temperature, fans, hard disks
(SMART, RAID, CF Card, SSD), watchdog
Operating hours counter for preventive maintenance
Integrated log functions, comprehensive text messages,
online help (English/German)
SIMATIC IPC Remote Manager
Efficient remote maintenance and management of
SIMATIC IPCs.
With the SIMATIC IPC Remote Manager you can use functions of
the Intel Active Management Technology (Intel AMT) for
SIMATIC IPCs. Intel AMT is used for remote management of PCs.
SIMATIC IPC BIOS Manager
The SIMATIC IPC BIOS Manager is a software tool with which
CMOS data from the BIOS configuration of a SIMATIC IPC can
be edited. The tool is obtained by downloading it from the
Internet using the Automation Value Card from Customer
Support.
ADDM Data Management
With ADDM, you are completely in control of the SIMATIC and
SINUMERIK controllers – around the clock and with any program
version. This tool, indispensable in modern production systems,
allows user-friendly backup, comparison and management of
control data.
DC-UPS uninterruptible power supplies
The uninterruptible DC power supply with battery modules
consists of DC UPS modules.
The maintenance-free SITOP UPS500 with capacitors as energy
stores are especially suitable for use at high ambient tempera-
tures. A further advantage of these high-capacity double-layer
capacitors is their shorter charging times.
For flexible use, there is the SITOP UPS500S – 15 A basic unit in
2.5 kW and 5 kW versions. Up to 3 SITOP UPS501S expansion
modules of 5 kW each can be connected in parallel to extend the
backup times. The SITOP UPS500P IP65 version has capacitors
for 5 or 10 kW and supplies up to 7 A output current.
Input and output devices
The SIMATIC IPC accessories encompass various input
devices.
ST80_2013_EN_Kap05.book Seite 154 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Expansion components and accessories
SIMATIC IPC CompactFlash
5/155
Siemens ST 80 / ST PC · 2013
Overview
Rugged systems are required when using PCs in industrial
environments to ensure minimal production standstill times.
SIMATIC IPCs have been developed precisely for this purpose.
One possibility for enhancing the industrial compatibility and
system availability of the SIMATIC IPC is to use SIMATIC IPC
CompactFlash instead of hard disk drives. These have been
system-tested with the respective SIMATIC IPC.
SIMATIC IPC CompactFlash can be ordered as a hardware
option through SIMATIC IPC Configurator or as an accessory.
Depending on the application, cards are available with a storage
capacity ranging from 2 GB to 16 GB.
The SIMATIC IPC CFast memory cards are readily replaceable
mass storage units for SIMATIC IPC427D and IPC477D. They
are connected via a SATA interface.
As a result of the different interface, the SIMATIC IPC CFast
memory cards are not compatible with the SIMATIC IPC
CompactFlash memory cards.
Ordering data
Order No.
Overview
The SIMATIC IPC USB FlashDrive is the ideal mobile storage
medium for industrial applications.
Thanks to the rugged and ultra-compact construction in a metal
enclosure, fast data transfer (USB 2.0) and the high memory
capacity of 8 GB, the USB FlashDrive is ideally suited for use in
industrial applications.
It replaces diskettes, CD and DVD read/write media as data
memory. Thanks to its high access speed, it is also ideal for tools
that are not to be installed on the computer ("portable apps").
In addition, it can be set up ready to boot using
SIMATIC PC BIOS-Manager. There is an option of expanding
the USB FlashDrive set up in this way into a "tool stick" using
SIMATIC IPC Image & Partition Creator.
The SIMATIC IPC SERVICE USB FlashDrive is the perfect tool for
backup and restoring. With the pre-installed SIMATIC IPC Image
& Partition Creator V3.1, it is immediately ready to use.
Technical specifications
Ordering data
Order No.
SIMATIC IPC CompactFlash
•2GB 6ES7648-2BF02-0XF0
•4GB 6ES7648-2BF02-0XG0
•8GB 6ES7648-2BF02-0XH0
•16GB 6ES7648-2BF02-0XJ0
SIMATIC IPC CFast
•2GB 6ES7648-2BF10-0XF0
•4GB 6ES7648-2BF10-0XG0
•8GB 6ES7648-2BF10-0XH0
•16GB 6ES7648-2BF10-0XJ0
SIMATIC IPC USB FlashDrive
SIMATIC IPC Service USB FlashDrive
Supported operating systems Windows 2000/XP/Vista/Windows 7/
Windows Server 2003/2008
Capacity 8GB
Approvals CE Industry
Temperature
• During operation +5 ... +55 °C
•Storage -40 ... +70 °C
Device dimensions (L x W x H) in mm 59.1 x 16.7 x 7
Weight, approx. 12 g
SIMATIC IPC USB FlashDrive 6ES7648-0DC50-0AA0
8 GB (SLC), USB 2.0,
metal enclosure, boot capability,
SIMATIC IPC BIOS Manager V3.2
preinstalled for SIMATIC IPC:
Rack PC, Box PC, Panel PC and for
SIMATIC PG
SIMATIC IPC Service USB
FlashDrive 6AV7672-8JD01-0AA0
8 GB (SLC), USB 2.0,
metal enclosure, boot capability,
SIMATIC IPC Image & Partition
Creator V3.2 and SIMATIC IPC BIOS
Manager V3.2 (Win PE) preinstalled,
including CD
SIMATIC IPC USB FlashDrive
ST80_2013_EN_Kap05.book Seite 155 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Expansion components and accessories
PC I/O
5/156 Siemens ST 80 / ST PC · 2013
5
Overview
The PC IO expansion extends the rugged use of the
SIMATIC HMI IPC427C at the machine level.
You can find further information under
Industrial PC -> SIMATIC PC -> SIMATIC Box PC.
The I/O expansion enables and supplements the use of the
SIMATIC HMI IPC427C with:
Extremely compact dimensions
(262 mm wide, 134 mm high, depth from 47 mm)
High system availability (rugged and maintenance-free, since
without rotating parts, for example)
Maximum flexibility
The PC IO expansion comprises:
Base module with encoder/counter functionality, PCI104
interface to the HOST system and communication interfaces
to the I/O modules
Digital and analog I/O modules that are managed by the basic
module
Mechanical installation components
A selection guide with material list for your requirements can be
found at:
http://www.siemens.com/simatic-pc/pc-io-selection
Technical specifications
Electrical data
Supply voltages and current consumption
Module Description
PC IO Base 400
(base module) PCI104 interface to host
4 encoder inputs, can also be used
as counters if required
4 digital inputs
Management of encoder inputs
and associated counters and up to
four I/O modules over separate
communication interfaces
• Power supply distribution
for 4 encoders
PC IO MOD Digital 010
(digital I/O module 0) • 24 binary 24 V inputs
• 16 binary 24 V outputs
PC IO MOD Analog 020
(analog I/O module 0) 8 analog inputs, 12 bits,
0 to 5 V, 0 to 10 V ±5 V, ±10 V
8 analog outputs, 16 bits, ±10V
4 Pt100 connections, 2-wire
PC IO KIT 040
(encoder expansion rack) For expanding a SIMATIC Microbox
PC 420/427B/IPC427C.
Connection unit for:
4 encoder inputs
4 digital inputs
Encoder voltage supply
PC IO KIT 030
(I/O expansion rack) For expanding a
SIMATIC Microbox
PC 420/427B/IPC427C.
Expansion rack to hold
• max. 2 I/O modules in the
Microbox PC 42x system
Parameters Value
Power supply to base module Via PCI-104 interface:
3.3 V DC and 5 V DC
Encoder supply voltage infeed 24 V DC
Current consumption of encoder
inputs and counters 0.3 A per encoder
Power supply to digital I/O module 0 24 V DC
Current consumption of digital I/O
module 0, max. approx. 4A
Power supply to analog I/O module 0 5 V DC from Base 400
Current consumption of analog I/O
module 0, max. approx.
ST80_2013_EN_Kap05.book Seite 156 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Expansion components and accessories
PC I/O
5/157
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
Counters and encoder inputs
Digital inputs on base module
Base module: Digital inputs
Digital I/O module 0: Digital inputs:
Digital I/O module 0: Digital outputs
Parameters Value
Number of counters or encoder inputs
on the base module 4
Input signal from encoder RS 422
Counting depth 32 bits
Encoder input counting frequency 2MHz
Sampling time for timer or pulse-width
measurement 1MHz or 4MHz
Gate time for frequency measurement Adjustable in the following stages:
8 µs, 32 µs, 128 µs, 512 µs,
2048 µs, 8192 µs, 16384 µs,
32768 µs, 131072 µs, 262144 µs,
524288 µs, 1048576 µs,
2097152 µs, 4194304 µs,
8388608 µs, 16777216 µs
Isolation No
Protected against polarity reversal No
Parameters Value
Number of digital inputs 4
Cable length
(without lightning protection element) max. 30 m
Input voltage 24 V DC
Input current Approx. 2 mA
Time constant of input filter 0.01 ms
Isolation No
Parameters Value
Number of digital inputs 24
Cable length
(without lightning protection element) max. 30 m
Input voltage 24 V DC
Input current Approx. 2 mA
Time constant of input filter:
Inputs 0 … 7 0.1 ms
Inputs 8 … 23 1ms
Inputs 8 and 9 also designed as
high-speed inputs
(parallel to 1 ms path)
0.01 ms
Isolation
For communication between the base
module and the inputs of digital I/O
module 0
Yes
Isolation test voltage 500 V DC
Between the individual inputs/outputs
of digital I/O module 0 No, one electrical circuit
Parameters Value
Number of outputs 16,
Organized in 4 output groups
Cable length
(without lightning protection element) max. 30 m
Output voltage 24 V DC
Output current:
• Per output group 1A max.
• Total per digital I/O module 0 4A max.
Switching rate 2kHz
Switching type Current sourcing
Output delay:
Internal transmission delay 16 µs
Register output to driver output
(load-dependent):
•01 signal max. 30 µs
•10 signal
(with a digital input connected) max. 130 µs
Isolation:
For communication between the
base module and the outputs of
digital I/O module 0
Yes
Isolation test voltage 500 V DC
Between the individual inputs/outputs
of digital I/O module 0 No, one electrical circuit
Short-circuit protection of the output
drivers Threshold on
Typ. 9 A max. 11 A electronically
pulsing
In order to comply with UL require-
ments, the user must limit the input
current to 4 A.
Use NEC Class 2 current source
Excess temperature shutdown Above 150 °C
Overvoltage protection Typ. 47 V
max. 52 V
Status after POWER ON and
after RESET High resistance
ST80_2013_EN_Kap05.book Seite 157 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Expansion components and accessories
PC I/O
5/158 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
5
Analog I/O module
Analog I/O module 0: Analog inputs
Analog I/O module: Pt100 inputs
Analog I/O module 0: Analog outputs
1)
The times also depend on the software response time
(interrupt response time or polling times).
Parameters Value
Number of analog inputs 8
Shielded cable length max. 30 m
Voltage ranges 0 … 5 V
0 … 10 V
±5 V
±10 V
Permissible input voltage
against analog ground max. 15 V, continuous
Impedance >10kOhms
Input type Single-ended
Resolution 12 bits (including sign)
Repeatability 10 bits (including sign)
Input filters No
Conversion time max. 200 µs per channel
Configuration cycle time
for analog-to-digital conversion: Without Pt100 With Pt100
With one analog input 50 ... 100 µs 50 ... 200 µs
With 4 analog inputs 200 ... 400 µs 200 ... 500 µs
With 8 analog inputs 400 ... 800 µs 400 ... 1000 µs
Isolation No
Parameters Value
Number of external Pt100 inputs 4
Type Two-wire measurement
Dynamic response The mean value is constantly avail-
able and is updated approximately
every 6 ms.
Isolation No
Parameters Value
Number of analog outputs 8
Type Single-ended
Shielded cable length max. 30 m
Voltage range ±10 V
Load current 2mA max.
Resolution 16 bits (including sign)
Accuracy 0.5 %
Conversion time max. 200 µs per channel
Output value after POWER ON and
after RESET 0V
Configuration cycle time for
digital-to-analog conversion
1)
:
• With one analog input 100 ... 200 µs
• With 4 analog inputs 400 ... 800 µs
• With 8 analog inputs 800 ... 1600 µs
Short-circuit protection No
Isolation No
ST80_2013_EN_Kap05.book Seite 158 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Expansion components and accessories
PC I/O
5/159
Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
Environmental requirements for installation in Microbox PC 42x
Degree of protection to EN 60529
(front/rear) IP20
Protection class Protection class I acc. to VDE 0106 Part 1 (IEC 536)
Vibration load during operation Devices without hard disk:
Frequency Acceleration Displacement Cycles per axis Octaves/min
10 to 58 Hz -0.075 mm 10 1
58 to 200 Hz 9.8 m/s
2
-10 1
acc. to IEC 60068-2-6, test Fc
Devices with hard disk: Wall mounting
Frequency Acceleration Displacement Cycles per axis Octaves/min
10 to 58 Hz 0.035 mm 10 1
58 to 200 Hz 4.9 m/s
2
10 1
Standard rail: No mechanical excitation permitted
Shock loading during operation Devices without hard disk:
Acceleration Shock duration
150 m/s
2
11 ms
acc. to IEC 60068-2-27, test Ea
3 in both pos. and neg. direction per axis, half-sine
Devices with hard disk: Wall mounting:
Acceleration Shock duration
50 m/s
2
30 ms
Standard rail: No mechanical excitation permitted
Electromagnetic compatibility (EMC)
Emitted interference EN 55022 Class B
In order to comply with Class B, a 230 V AC power supply unit must be used which meets the requirements
of EN 55022 Class B (e.g. "SITOP modular 5 A", type No.: 6EP1333-3BA00).
Immunity to conducted interference
on the supply lines ±2 kV (IEC 61000-4-4, Burst)
±1 kV (IEC 61000-4-5, symm. surge, length > 30 m)
with lightning protection element (e.g. from Dehn, type "Blitzductor BVT AD24", type No.: 918402)
±2 kV (IEC 61000-4-5, unsymm. surge, length > 30 m)
with lightning protection element (e.g. from Dehn, type "Blitzductor BVT AD24", type No.: 918402)
Immunity to conducted interference
on the unshielded supply lines ±2 kV (IEC 61000-4-4, burst)
±1 kV (IEC 61000-4-5, symm. surge, length > 30 m)
with lightning protection element (e.g. from Dehn, type "Blitzductor BVT AD24", type No.: 918402)
• ±2 kV (IEC 61000-4-5, unsymm. surge) Length > 30 m)
with lightning protection element (e.g. from Dehn, type "Blitzductor BVT AD24", type No.: 918402)
Immunity to conducted interference
on the shielded supply lines • ±2 kV (IEC 61000-4-4, burst)
±1 kV (IEC 61000-4-5, surge symm., length > 30 m)
±2 kV (IEC 61000-4-5, surge unsymm., length > 30 m)
Immunity to static discharge ±6 kV, contact discharge (IEC 61000-4-2)
• ±8 kV, air discharge (IEC 61000-4-2)
Immunity to radio frequ. interference 10 V/m 80 % AM; 80 MHz to 1 GHz (IEC 61000-4-3);
• 10 V/m 80 % AM; 1.4 GHz to 2 GHz (IEC 61000-4-3)
Immunity to high-frequ. current feed • 10 V 80 % AM, 9 kHz to 80 MHz (IEC 61000-4-6)
Ambient temperature during operation 0 to 50 ºC with Flash drive (horizontal; preferred mounting position)
0 to 45 ºC with Flash drive (vertical)
5 to 40 ºC with hard disk (horizontal and vertical)
Ambient temperature during storage
and transport -20 °C … +60 °C
Moist heat 30 °C/85 % (IEC 60068-2-78, Test Cab)
Approvals
Safety regulations IEC/EN 60950-1
CE marking • EC Directive 89/336/EEC (EMC Directive)
Use in industry:
Applications in residential areas, business and trade environments as well as in workshops:
- Emitted interference: EN 61000-6-4
- Noise immunity: EN 61000-6-2
Applications in residential areas, business and trade environments as well as in workshops:
- Emitted interference: EN 61000-6-3
- Noise immunity: EN 61000-6-1
Dimensions and weights
Equipment dimensions (in mm) Width x height: 262 x 134
Depth of basic unit: 47
Depth of basic unit above rail: 52
Additional depth per encoder expansion rack (Kit 040): 17
Additional depth per I/O expansion rack (Kit 030): 22
ST80_2013_EN_Kap05.book Seite 159 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Expansion components and accessories
PC I/O
5/160 Siemens ST 80 / ST PC · 2013
5
Ordering data
Order No. Order No.
PC IO Base 400 6ES7648-2CE20-0AA0
PCI104 module for connecting
up to 4 PC IO MOD xxx 010/020,
with 4 encoder interfaces and 4 DI
incl. fixing accessories (base
module with fixing accessories)
PC IO MOD Digital 010 6ES7648-2CE40-0BA0
Digital I/O module
with 24 DI and 16 DO,
incl. connecting cable to
PC IO Base 400 and
mating connector
PC IO MOD Analog 020 6ES7648-2CE40-0CA0
Analog I/O module with 8 AI,
8 AO and 4 PT100,
incl. connecting cable to
PC IO Base 400,
mating connector and shield clamp
PC IO KIT 030 6ES7648-1AA20-0XF0
I/O module expansion rack for
Microbox PC 420/427B/IPC427C
for installing up to 2 I/O modules,
including fixing accessories and a
cover plate
PC IO KIT 040 6ES7648-1AA20-0XE0
Encoder expansion rack for
Microbox PC 420/427B/IPC427C
for contacting the encoder
interfaces and DIs of the
PC IO Base 400,
including fixing accessories
ST80_2013_EN_Kap05.book Seite 160 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Expansion components and accessories
SIMATIC Panel PC Remote Kit
5/161
Siemens ST 80 / ST PC · 2013
Overview
The Remote Kit makes it possible to separate the Panel PC 677B
operator control unit from the computer unit and install them up
to 30 m apart.
Technical specifications
Ordering data
Order No.
1)
A European power supply cable is included in the scope of delivery of the
AC (100-240 V) version of the Remote Kit.
SIMATIC Panel PC Remote Kit
Design Subsequent installation on the
Panel PC 677B operator control unit
Supported operator control units All Panel PC 677B operator control
units:
12" Touch/Key
15" Touch/Key
•17" Touch
•19" Touch
Cable sets •5 m
•10 m
•15 m
•20 m
•30 m
Front panel functionality As centralized installation with the
following constraint in respect of
USB functionality:
• Distance 5 m: USB 2.0,
and only one external 2.0 Hub
Distance > 5 m: USB 1.1,
and only one external 1.1 Hub
External ports 2 additional USB ports on the
remote module (on the rear of the
remote operator control unit)
Power supply 24 V DC; 20.4 ... 28.8 V DC or
110 ... 240 V AC; 50/60 Hz
Approvals CE, cULus (UL 508)
Scope of supply Remote module
•Cable set
• Mounting accessories for the
PC 677B computer unit
• European power supply cable
(with the AC option)
SIMATIC Panel PC Remote Kit
24 V DC, 5 m 6AV7671-1EA00-5AA1
24 V DC, 10 m 6AV7671-1EA01-0AA1
24 V DC, 15 m 6AV7671-1EA01-5AA1
24 V DC, 20 m 6AV7671-1EA02-0AA1
24 V DC, 30 m 6AV7671-1EA03-0AA1
100/240 V AC, 5 m 6AV7671-1EA10-5AA1
100/240 V AC, 10 m 6AV7671-1EA11-0AA1
100/240 V AC, 15 m 6AV7671-1EA11-5AA1
100/240 V AC, 20 m 6AV7671-1EA12-0AA1
100/240 V AC, 30 m 6AV7671-1EA13-0AA1
Accessories
Power supply cable
Europe: D/F/NL/E/B/A/S/FIN
1)
6ES7900-1AA00-0XA0
United Kingdom 6ES7900-1BA00-0XA0
Switzerland 6ES7900-1CA00-0XA0
USA 6ES7900-1DA00-0XA0
Italy 6ES7900-1EA00-0XA0
China 6ES7900-1FA00-0XA0
Sub-components
of the Remote Kit
(only available individually
as spare parts)
24 V DC remote module
with fixing accessories 6AV7671-1EX01-0AD0
110/240 V AC remote module
with fixing accessories 6AV7671-1EX01-0BD0
USB amplifier/CAT6 converter 6AV7671-1EX02-0AB0
5 m cable set
(DVI, USB standard cable) 6AV7671-1EX10-5AA0
10 m cable set (DVI, Cat 6 cable) 6AV7671-1EX11-0AA0
15 m cable set (DVI, Cat 6 cable) 6AV7671-1EX11-5AA0
20 m cable set (DVI, Cat 6 cable) 6AV7671-1EX12-0AA0
30 m cable set (DVI, Cat 6 cable) 6AV7671-1EX13-0AA0
ST80_2013_EN_Kap05.book Seite 161 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Expansion components and accessories
SIMATIC Panel PC Remote Kit
5/162 Siemens ST 80 / ST PC · 2013
5
Dimensional drawings
All dimensions in mm. For mounting cut-out see technical specifications.
Front dimensions WH
Touch panels
12"
15"
19"
Key Panels
12"
15"
400
483
483
483
483
310
310
400
310
355
Installation cutout
Touch panels
12"
15"
19"
Key Panels
12"
15"
368
450
450
450
450
290
290
380
290
321
95
93
102
77
96
W+1 H+1 D
*
H
W
W+1 (cutout)
H+1 (cutout)
10.5
D
* In addition: two recesses 25 x 5 mm on the top side
for keyboard slide-in label channels
G_ST80_XX_00267
ST80_2013_EN_Kap05.book Seite 162 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Expansion components and accessories
SIMATIC IPC Image & Partition Creator
5/163
Siemens ST 80 / ST PC · 2013
Overview
SIMATIC IPC Image & Partition Creator is the software tool for
easy, preventive back-up and restoring of hard disk contents
(images of individual partitions or complete hard disks). This
software can be ordered through the Configurator for the
SIMATIC IPCs, or separately with single license.
Can run on all SIMATIC IPCs, regardless of the computer
configuration
Direct starting from the CD possible (no installation required)
Complete backup by means of a mouse double-click with
"1ClickImage" (must be installed)
Menu-driven creation of a bootable USB flash drive as an
alternative start medium from which SIMATIC IPC Image &
Partition Creator can be started.
Independent of the operating system thanks to ability to start
from the bootable SIMATIC IPC Image & Partition Creator CD
or bootable USB flash drive with Image & Partition Creator
Ordering data
Order No.
Note:
SIMATIC IPC Image & Partition Creator is also available together
with the SIMATIC IPC BIOS Manager preinstalled with the
SIMATIC IPC Service USB FlashDrive.
SIMATIC IPC Image & Partition
Creator V3.3 Can be ordered using the
SIMATIC IPC Configurator
SIMATIC IPC Image & Partition
Creator V3.3 6ES7648-6AA03-3YA0
Software tool for very easy preven-
tive data backup and efficient parti-
tion management on SIMATIC IPCs
ST80_2013_EN_Kap05.book Seite 163 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Expansion components and accessories
SIMATIC IPC DiagMonitor
5/164 Siemens ST 80 / ST PC · 2013
5
Overview
SIMATIC IPC DiagMonitor: Intelligent and comprehensive
diagnostics for the SIMATIC IPC – local and remote.
The SIMATIC IPC DiagMonitor software for monitoring and
remote signaling detects possible hardware and software faults
at an early stage. It monitors, signals and visualizes the
operating statuses of the SIMATIC IPC both locally and remotely.
DiagMonitor V4.4 can run on the following SIMATIC IPCs:
Microbox PC 427B
Box PC 627B/827B
Rack PC IL 43 / 547B / 647B / 847B
Panel PC 477B/577B/677B
IPC427C / IPC627C / IPC827C
IPC547C / IPC647C / IPC847C
HMI IPC477C / HMI IPC477C PRO / HMI IPC577C /
HMI IPC677C
IPC227D / IPC277D / IPC427D / IPC477D / IPC547D
The software can be ordered as:
Individual product from stock (e.g. for server applications on
third-party PCs or immediate integration in new systems) or
Option ordered according to the SIMATIC IPC configurator
(Internet, Mall).
(DiagMonitor V3.1 is used with SIMATIC Microbox PC 420/427B,
Box PC 627/627B, Rack PC IL 43/840/847B, Panel PC 477/477B/
677/677B/877 and can be ordered directly via the PC configu-
rator or as an individual product.)
Ordering data
Order No.
SIMATIC IPC DiagMonitor V4.4 Can be ordered using the
SIMATIC IPC Configurator
SIMATIC IPC DiagMonitor V4.4 6ES7648-6CA04-4YX0
Software tool for monitoring the
SIMATIC IPC,
incl. manual on CD ROM
(English, German), single license
ST80_2013_EN_Kap05.book Seite 164 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Expansion components and accessories
SIMATIC IPC Remote Manager
5/165
Siemens ST 80 / ST PC · 2013
Overview
SIMATIC IPC Remote Manager
Efficient remote maintenance and management of
SIMATIC IPCs.
With the SIMATIC IPC Remote Manager you can use functions
of the Intel active management technology (Intel AMT) for
SIMATIC IPCs. Intel AMT is used for remote management of
PCs.
Intel AMT offers a range of functions, such as:
Remote reboot
IDE redirection
Keyboard video mouse redirection
Power on / off / reset, and
an integrated Web server.
http://support.automation.siemens.com/WW/view/en/56230140
Ordering data
Order No.
AMT clients
With AMT
Without AMT
Administrator
• Easy access on SIMATIC IPC
• No additional hardware (e.g. KVM switch)
• Over secure connections
Central service
• Saves electricity cost
• Efficient use of production time
Resource management
ProductionControl
• Troubleshooting
• No operating system required
• BIOS and program updates
• Remote filling (supports ISO image > 2 GB)
• Configurable time-out
Remote diagnostics and access without on-site support
G_ST80_XX_00443
SIMATIC IPC Remote Manager
V1.2 6ES7648-6EA01-2YA0
Software tool for remote
maintenance and management
of SIMATIC IPC,
incl. manual on CD-ROM
(English, German), single license
ST80_2013_EN_Kap05.book Seite 165 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Expansion components and accessories
SIMATIC IPC BIOS Manager
5/166 Siemens ST 80 / ST PC · 2013
5
Overview
The SIMATIC IPC BIOS Manager V3.3 (WinPE) is a software tool
for the management and processing of SIMATIC IPC BIOS data.
The tool is obtained by downloading it from the
Service & Support web pages of Industry Automation & Drive
Technologies using the Automation Value Card.
http://support.automation.siemens.com/WW/view/en/58512643
Ordering data
Order No.
Note:
SIMATIC IPC BIOS Manager is also available together with the
SIMATIC IPC USB FlashDrive and IPC Service USB FlashDrive.
SIMATIC IPC BIOS Manager available as a download
from Customer Support
http://support.automa-
tion.siemens.com/WW/
view/en/58512643
Software tool for the
management and processing of
SIMATIC IPC BIOS data
ST80_2013_EN_Kap05.book Seite 166 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Input and output devices
SIMATIC PC keyboard
5/167
Siemens ST 80 / ST PC · 2013
Overview
The original SIMATIC PC keyboard is the ideal input medium for
your SIMATIC PC. It combines the convenience of an office
keyboard with the ruggedness of an industrial device. The
SIMATIC PC keyboard is available with a USB connection and
German/international layout.
Technical specifications
Ordering data
Order No.
SIMATIC PC keyboard
Description SIMATIC PC keyboard
Layout MF2, 105 keys,
German/international
Dimensions (L x W x H) in mm 470 x 195 x 44
Weight, approx. 1400 g
Connecting cable Length 1.75 m, USB plug
Temperature
• During operation 0 ... +50 °C
•Storage -20 ... +60 °C
Current consumption -
Current delivery -
Transmission rate -
Approvals FCC, cURus, GS, CE, c-tick,
GOST-R
SIMATIC PC keyboard 6ES7648-0CB00-0YA0
German/international,
USB connection
incl. USB-PS2 adapter
ST80_2013_EN_Kap05.book Seite 167 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Input and output devices
IP65 membrane keyboard, desk version
5/168 Siemens ST 80 / ST PC · 2013
5
Overview
The desktop version of the IP65 membrane keyboard is ideal for
use in industrial areas in which a high degree of protection (IP65)
is required. The keyboard is equipped with a touchpad.
Technical specifications
Color “light-basic”
MF2/Windows 95 compatible key layout
with 105 short-stroke keys, type Omron
German or international key layout
Desktop unit made of polyester
Mounting plate and base made of metal
Front membrane made of resistant polyester (150 µm thick)
1 million strokes per key
Y cable with 2 PS/2 connectors with 1.8 m connecting cable
Weight approx. 1190 g
Dimensions in mm (W x D x H): 478.6 x 180 x 26
Licences: UL 1950, CSA C22.2 No. 950
CE conformity according to EC 89/336
Degree of protection IP65
Ordering data
Order No.
Overview
The built-in version of the IP65 membrane keyboard is ideal
for use in industrial areas in which a high degree of protection
(IP65 at the front, IP54 at the rear) is required. The keyboard is
specially designed for installation in 19" cabinets.
Technical specifications
Color “light-basic”
MF2/Windows 95 compatible key layout with 105 short-stroke
keys, type Omron
German or international key layout
Desktop unit made of polyester
19“/4HU mounting plate made of metal (1.6 mm thick)
Front membrane made of resistant polyester (180 µm thick)
Touchpad or trackball (IP65 version)
Y cable with 2 PS/2 connectors with 1.8 m connecting cable
Weight approx. 1480 g
Dimensions in mm (W x D x H): 482.6 x 177.8 x 42.5
Licences: UL 1950, CSA C22.2 No. 950
CE conformity according to EC 89/336
IP65 protection at the front, IP54 at the rear
Ordering data
Order No.
Standard configuration
IP65 membrane keyboard,
desktop version with touchpad
With PS/2 connector
• German keyboard layout 6GF6710-2AC
• International keyboard layout 6GF6710-2BC
IP65 membrane keyboard, 19" built-in version
Standard configuration
IP65 membrane keyboard,
19" built-in version
For installation in 19" cabinets
With touchpad
• German keyboard layout 6GF6710-3AE
• International keyboard layout 6GF6710-3BE
With trackball
• German keyboard layout 6GF6710-3BF
• International keyboard layout 6GF6710-3BG
ST80_2013_EN_Kap05.book Seite 168 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Input and output devices
19" slide-in keyboard PS/2 with trackball
5/169
Siemens ST 80 / ST PC · 2013
Overview
With its compact design and integrated trackball the new draw-
out keyboard is suitable in particular for industrial applications
with limited space. This can be, for example, cubicles or mobile
systems.
The draw-out keyboard is supplied in combination with a drawer.
Ordering data
Order No.
Overview
Robust mouse for harsh everyday use with a pleasantly coated
slip-free surface, precise BlueTrack technology, three buttons
incl. large scroll wheel, trouble-free cable operation and
symmetrical casing design for right-handed and left-handed
users.
Interface: USB
Operating systems: Microsoft Windows® 7, Windows Vista®
and Windows XP (not for Windows XP 64 bit)
Connection cable: 2 m long, USB plug
Approvals corresponding to office environment:
- ACA/MED Declaration of Conformity
(Australia and New Zealand)
- ICES-003 report on file (Canada)
- EIP Pollution Control Mark, EPUP (China)
- CE Declaration of Conformity, Safety and EMC
(European Union)
- WEEE (European Union)
- VCCI Certificate (Japan)
- KCC Certificate (Korea)
- GOST Certificate (Russia)
- BSMI Certificate (Taiwan)
- FCC Declaration of Conformity (USA)
- UL and cUL Listed Accessory (USA and Canada)
- CB Scheme Certificate (International)
Ordering data
Order No.
Standard configuration
19" withdrawable keyboard
With trackball
• German keyboard layout 6GF6710-3BJ
• International keyboard layout 6GF6710-3BK
SIMATIC IPC mouse
Optical (BlueTrack) wheel mouse,
USB interface
Color
• Anthracite 6ES7648-0BB00-0XA0
•White 6ES7648-0BB00-0XA1
SIMATIC IPC mouse
ST80_2013_EN_Kap05.book Seite 169 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SITOP power supplies
SITOP power supplies
5/170 Siemens ST 80 / ST PC · 2013
5
Overview
SITOP – reliable 24 V power supply
Efficient operation of a machine or plant requires a reliable,
constant power supply. The quality and reliability of the
SITOP stabilized power supplies ensure high levels of safety
in DC power supply in industrial engineering and building
management systems. They supply a stabilized 24 volts, but
also other output voltages. Even in the case of large input
voltage variations, the output voltage is kept stable with a high
degree of accuracy. This enables the use of primary switched-
mode power supplies in many applications for the supply of
sensitive electronic systems - all the way up to loads requiring
high currents.
The fan-free power supplies are characterized by their compact
and rugged design, high overload capability, as well as special
energy efficiency. The high efficiency across the entire load
range and the low no-load loss ensure efficient operation. The
large input voltage range and the international approvals mean
that use is possible in almost all supply networks worldwide.
The complete SITOP range
In addition to the power supplies, the perfectly coordinated,
complete range offers a unique choice of modules - from those
that protect the 24 V power supply against interference on the
primary and secondary side, right up to those providing
complete protection. Every day, SITOP is used successfully in
innumerable practical applications and protects against plant
downtimes and production outages.
Quick selection and fast delivery
With the SITOP Selection Tool - available in the Internet under
http://www.siemens.com/sitop-selection-tool and in the Industry
Mall – the suitable power supply can be selected quickly and
easily, the selected products can be saved or placed into the
Mall's shopping cart and then ordered there.
We deliver all SITOP standard products from stock to ensure that
you receive the SITOP power supply you selected quickly.
Customized SITOP products
Our standard power supplies cannot, of course, satisfy the
requirements of every application. We can design a specific
power supply for your application-specific requirements. You
benefit from the expertise of large-scale production and gain
maximum development security and quality.
Our customer-specific solutions are used today in many sectors
of mechanical engineering, in automation technology, vehicle
electronics, equipment manufacturing, or in industrial instru-
mentation technology. If your are interested, please contact your
local Siemens office.
ST80_2013_EN_Kap05.book Seite 170 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SITOP power supplies
1-phase, 24 V DC/10 A (SITOP PSU100S)
1-phase, 24 V DC/20 A (SITOP PSU100S)
5/171
Siemens ST 80 / ST PC · 2013
1-phase, 24 V DC/10 A (SITOP PSU100S)
The single-phase power supply for universal use; complies with
EU directive 94/9/EC (ATEX 100a); slim design; with 50 % extra
power for 5 s and 120 % rated power up to 45 °C.
Ordering data
Order No.
1-phase, 24 V DC/20 A (SITOP PSU100S)
High-performance, standard power supply for 1-phase
120/230 V AC grids, with automatic range switching;
high overload capability through Extra power with 1.5 times the
rated current for 5 s and continuous 120 % output power up to
+45 °C ambient temperature.
Ordering data
Order No.
SITOP PSU100S 24 V/10 A 6EP1334-2BA20
Stabilized power supply
Input: 120/230 V AC
Output: 24 V DC/10 A
SITOP smart 240 W 6EP1334-2AA01
Stabilized power supply
Input: 120/230 V AC
Output: 24 V DC/10 A
SIPLUS smart 10 A 6AG1334-2BA20-4AA0
For medial load
based on 6EP1334-2BA20
SITOP PSU100S 20A
Stabilized power supply;
Input: 120/230 V AC,
Output: 24 V DC/20 A
6EP1336-2BA10
ST80_2013_EN_Kap05.book Seite 171 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SITOP power supplies
3-phase, 24 V DC/10 A (SITOP PSU300S)
3-phase, 24 V DC/20 A (SITOP PSU300S)
5/172 Siemens ST 80 / ST PC · 2013
5
3-phase, 24 V DC/10 A (SITOP PSU300S)
High-performance, standard power supply for 3-phase networks
3 AC 400-500 V, high overload capability through Extra power
with 1.5 times the rated current for 5 s and continuous 120 %
output power to +45° C ambient temperature.
Ordering data
Order No.
3-phase, 24 V DC/20 A (SITOP PSU300S)
High-performance, standard power supply for 3-phase networks
3 AC 400-500 V, high overload capability through Extra power
with 1.5 times the rated current for 5 s and continuous 120 %
output power to +45° C ambient temperature.
Ordering data
Order No.
SITOP smart PSU300S 10 A 6EP1434-2BA10
Stabilized power supply;
input: 3 AC 400 … 500 V;
output: 24 V DC/10 A
Accessories
Device labels 3RT1900-1SB20
SITOP smart PSU300S 20 A 6EP1436-2BA10
Stabilized power supply
Input: 3 AC 400 ... 500 V
Output: 24 V DC/20 A
Accessories
Device labels 3RT1900-1SB20
ST80_2013_EN_Kap05.book Seite 172 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
SITOP power supplies
3-phase, 24 V DC/40 A (SITOP PSU300S)
5/173
Siemens ST 80 / ST PC · 2013
3-phase, 24 V DC/ 40 A (SITOP PSU300S)
High-performance, standard power supply for 3-phase networks
3 AC 400-500 V, high overload capability through Extra power
with 1.5 times the rated current for 5 s and continuous 120 %
output power to +45° C ambient temperature.
Ordering data
Order No.
SITOP PSU300S 40 A 6EP1437-2BA20
Stabilized power supply
Input: 3 AC 400 … 500 V
Output: 24 V DC/40 A
Accessories
SITOP PSE202U
redundancy module 6EP1961-3BA21
Input/output: 24 V DC/40 A
suitable for decoupling two SITOP
power supplies with a maximum of
20 A output current
Device labels 3RT1900-1SB20
ST80_2013_EN_Kap05.book Seite 173 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
24 V DC uninterruptible power supplies
24 V DC uninterruptible power supplies
5/174 Siemens ST 80 / ST PC · 2013
5
Overview
Permanently reliable 24 V – even when the power fails:
Uninterruptible power supply
Supply network irregularities in the millisecond range are
compensated for supremely well by all our power supplies.
Large fluctuations or even power failures, however, require
special measures: The buffer module (see SITOP add-on
modules) ensures optimal protection in the case of brief power
failures up to 3 seconds.
Longer power failures into the minute range can be bridged with
the new maintenance-free SITOP UPS500 with capacitor
technology.
The DC UPS modules with battery modules secure continued
operation for hours! Both DC UPS systems can be integrated
simply into PC-based automation solutions using a free software
tool.
The SITOP UPS500 is completely maintenance-free because
it saves energy in high-capacitance double-layer capacitors.
These have a long service life even in high temperatures, and do
not need to be replaced. The installation location does not have
to be ventilated because no gas is emitted. The innovative
DC UPS buffers 24 V into the minutes range and makes it
possible to back up data and to shut down PC-based applica-
tions (e.g. with SIMATIC PC) safely.
The SITOP UPS500S is designed for installing on a standard
mounting rail and it can be modularly expanded to extend the
backup time. The UPS500P in degree of protection IP65 is
suitable for distributed use.
The SITOP DC UPS with battery modules using lead gel
batteries up to 12 Ah enables process operation to continue for
hours. The availability, battery supply line, aging status, and
charge status are permanently monitored.
The integral battery management system ensures optimal
charging of the battery modules and a long service life.
High load current up to 40 A No ventilation is required since no gas
is emitted
For distributed applications without
control cabinet
Supports the power supply unit when there
is a temporary increased power demand High ambient temperatures up to 60°C
Absolutely maintenance-free
Low-cost protection against power
failures for max. 3 seconds
The 24 V power supply is maintained
for a long time, e.g. in order to continue
processes.
Backup data and closing of applications
within minutes.
Selection criteria:
Expansion module with electrolyte
capacitors for bridging temporary power
failures. Can be combined with SITOP
modular.
DC UPS module with maintenance-free
lead-gel batteries for energy storage.
Bridging of power failures even for hours.
DC UPS with high-capacity double-layer
capacitors. Bridging of power failures for
severyl minutes.
Backup module
Selection criteria:
SITOP UPS500
High load current up to 40 A
Selection criteria:
SITOP DC UPS module
G_ST80_XX_00486
SITOP UPS500
ST80_2013_EN_Kap05.book Seite 174 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
24 V DC uninterruptible power supplies
24 V DC uninterruptible power supplies
5/175
Siemens ST 80 / ST PC · 2013
Overview (continued)
DC UPS software
Monitoring and configuration window of software V3 for SITOP DC UPS
The uninterruptible DC power supplies are optionally available
with USB interface or serial interface. All relevant messages
about the status of the uninterruptible DC power supply can be
transferred to a PC (e.g. SIMATIC IPC) via this interface.
SITOP DC UPS software provides the user with a very easy to
use software tool with which the signals sent by the uninter-
ruptible DC power supply can be further processed on the PC.
In monitoring mode, the statuses of the uninterruptible DC power
supply are visualized on the PC.
Safe shutdown in the event of a power failure and automatic PC
restart are supported. It is also possible to freely define
responses to the different operating states of the uninterruptible
DC power supply, so that extremely flexible integration into a
wide variety of applications is possible.
The software runs under the Windows 2000, Windows XP,
Windows Vista and Windows 7 operating systems. It is available
as downloadable freeware on the SITOP homepage.
http://www.siemens.com/sitop-ups
More information
You can select the appropriate power supply quickly and easily
using the SITOP Selection Tool:
http://www.siemens.com/sitop-selection-tool
G_KT01_EN_00357
SITOP power supply
24 V DC
24 V DC
DC UPS module with battery module
Messages
- Mains or buffer operation
- Buffer ready or alarm
Charging status >85 % or <85 %
via USB interface or floating relay contacts
USB interface for data exchange with
industrial PC
SITOP UPS500S basic unit 15 A
maintanance-free with capacitor, optionally with
expansion module as additional energy storage
Load
AC or 3 AC
ST80_2013_EN_Kap05.book Seite 175 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
DC UPS with capacitors
DC UPS with capacitors
5/176 Siemens ST 80 / ST PC · 2013
5
Overview
Uninterruptible power supplies normally store the electrical
energy in lead-acid batteries. Temperatures such as those
prevalent in control cabinets considerably shorten the service
life of the battery, however, and the batteries must be replaced
on a regular basis – annually at an ambient temperature of 40 °C,
for example. The innovative SITOP UPS500, however, is based
on absolutely maintenance-free capacitors with a long service
life. Even at temperatures of 50 °C they still have more than 80%
of their capacity after 8 years. This means that the energy
storage unit does not have to be replaced. Because the capac-
itors do not emit any gas, the control cabinet does not have to be
ventilated.
Another advantage is the significantly shorter charging times of
the double-layer capacitors, which ensure that the buffer is
ready very quickly after loss of power.
The SITOP UPS500P IP65 version has capacitors for 5 or 10 kW
and supplies up to 7 A output current. The oblong metal
enclosure is also suitable for installing on support arm systems.
Selection table SITOP UPS500
(optional with SITOP UPS501S expansion module)
and mains buffering times
Important information for selecting the energy storage units:
When the mains buffering times were determined, the discharge
period of new or non-aged, completely charged capacitors was
used as a basis. At a continuous ambient temperature of +50 °C,
a loss of capacity of approx. 20% must be considered after a
service life of 8 years.
More information
You can select the appropriate power supply quickly and easily
using the SITOP Selection Tool:
http://www.siemens.com/sitop-selection-tool
Buffering and charging times
SITOP UPS500S/501S configurations UPS500P
Basic unit 2.5 kW 5kW 2.5 kW 5kW 2.5 kW 5kW 2.5 kW 5kW 5kW 10 kW
Expansion
modules - - 1×5kW 1×5kW 2×5kW 2×5kW 3×5kW 3×5kW - -
Total energy 2.5 kW 5kW 7.5 kW 10 kW 12.5 kW 15 kW 17.5 kW 20 kW 5kW 10 kW
Load current Buffer times
0.5 A 134 s 236 s 390 s 478 s 632 s 748 s 851 s 1007 s 284 s 647 s
0.8 A 90 s 167 s 266 s 346 s 440 s 527 s 580 s 706 s 190 s 435 s
1A 75 s 138 s 219 s 296 s 365 s 414 s 490 s 572 s 153 s 351 s
2A 38 s 76 s 122 s 156 s 203 s 230 s 265 s 306 s 80 s 152 s
3A 26 s 52 s 82 s 106 s 136 s 159 s 186 s 213 s 53 s 108 s
4A 19 s 39 s 61 s 81 s 101 s 120 s 139 s 160 s 40 s 84 s
5A 15 s 31 s 49 s 65 s 81 s 95 s 111 s 130 s 30 s 68 s
6A 12 s 26 s 40 s 55 s 67 s 80 s 94 s 106 s 25 s 57 s
7A 10 s 21 s 34 s 47 s 58 s 69 s 81 s 82 s 21 s 49 s
8A 8s 18 s 29 s 40 s 50 s 59 s 69 s 79 s - -
10 A 6s 15 s 23 s 32 s 39 s 47 s 54 s 62 s - -
12 A 4s 12 s 19 s 26 s 32 s 38 s 44 s 52 s - -
15 A 3s 9s 14 s 20 s 25 s 30 s 35 s 40 s - -
Charging
current Charging times
2A 54 s 120 s 158 s 223 s 263 s 318 s 355 s 417 s 130 s 360 s
1A 110 s 205 s 311 s 425 s 503 s 625 s 695 s 816 s - -
ST80_2013_EN_Kap05.book Seite 176 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
DC UPS with capacitors
SITOP UPS500S
5/177
Siemens ST 80 / ST PC · 2013
Overview
Basic device 15 A, SITOP UPS500S
Compact design, only 120 mm wide
Two versions with integrated energy storage units:
2.5 kW or 5 kW
Can be expanded easily using a user-friendly plug-in system
with the expansion module 5 kW
Absolutely uninterruptible bridging of power failures, as soon
as the DC UPS input voltage falls below the value set by the
DIP switches
High level of safety and availability through monitoring of
operational readiness, and monitoring of the capacitor charge
(message "> 85% charged")
Support for automatic warm restart of industrial PCs through
selectable shutdown characteristics
With USB interface
Maintenance-free power supply in the form of a combination of a basic
module and an expansion module
SITOP UPS501S expansion module
Additional energy storage (5 kW)
Up to 3 expansion modules can be connected to a
SITOP UPS500S to extend the buffer times
Compact design, only 70 mm wide
Can be easily connected to SITOP UPS500S
via a user-friendly plug-in system
Complete with balancing and safety circuits
Can be snapped onto standard mounting rail
EN 60715 35x7.5/15
Dimensions (W x H x D) in mm: Approx. 70 x 125 x 125
Weight: Approx. 0.7 kg
Ordering data
Order No.
SITOP UPS500S
DC UPS basic device 15 A with
•2.5kW 6EP1933-2EC41
•5kW 6EP1933-2EC51
SITOP UPS501S
Expansion module 5 kW for
connecting to the basic device 6EP1935-5PG01
Accessories
Device labels 3RT1900-1SB20
ST80_2013_EN_Kap05.book Seite 177 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
DC UPS with capacitors
SITOP UPS500P
5/178 Siemens ST 80 / ST PC · 2013
5
Overview
Basic device 7 A, IP65, SITOP UPS500P
Compact design, degree of protection IP65
For distributed use, e.g. on support arms
Integrated energy storage: 5 kW or 10 kW
Ambient temperature range for operation: 0 to +55 °C
High degree of efficiency 96.9% or low power loss, approx.
6 W with 7 A load current
USB interface
Indication of the operating states normal operation, buffer
mode, alarm message "Buffer not ready" and indication of the
capacitor charge > 85%
Ordering data
Order No.
SITOP UPS500P
DC UPS basic device 7 A with
•5kW 6EP1933-2NC01
•10kW 6EP1933-2NC11
Connector set
consisting of connector for input and
output and an assembled USB cable
(2 m in length)
6EP1975-2ES00
ST80_2013_EN_Kap05.book Seite 178 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
DC UPS with battery modules
DC UPS with battery modules
5/179
Siemens ST 80 / ST PC · 2013
Overview
By combining a DC UPS module with at least one 24 V battery
module and a SITOP power supply unit, longer power failures
can be bridged without any interruption.
The combination is used for example in machine-tool building, in
the textile industry, on all types of production lines and filling
plants, and in conjunction with 24 V industrial PCs. This prevents
the negative effects which often result from power failures.
DC UPS modules: 6 A, 15 A, 40 A
Battery modules:
1.2 Ah (contains lead-acid batteries with corrosion-resistant
lead-calcium high-performance grid plates and fiberglass
mat)
3.2 Ah (contains lead-acid batteries with corrosion-resistant
lead-calcium high-performance grid plates and fiberglass
mat)
7 Ah (contains lead-acid batteries with corrosion-resistant
lead-calcium high-performance grid plates and fiberglass
mat)
12 Ah (contains lead-acid batteries with corrosion-resistant
lead-calcium high-performance grid plates and fiberglass
mat)
2.5 Ah (contains "high-temperature battery" type pure lead)
Selection table for battery modules and mains buffering times
Important information for selecting the battery capacity:
Determination of the mains buffering times is based on the
discharge period of new or non-aged, completely charged
battery modules at a battery temperature not below +25 °C to
the shutdown of the DC UPS.
Battery aging reduces the still available battery capacity up
until the end of the service life to typically around 50 % of the
original capacity value when new (1.2 Ah/3.2 Ah/7 Ah, etc.)
and the internal resistance increases. When the message
"Battery charge > 85%" appears, only around 50% x 85% =
approx. 43% of the originally available capacity can be
assumed at the end of the battery service life.
At battery temperatures below +25 °C, the available capacity
is further reduced by approx. 30% at +5 °C battery temper-
ature to approx. 70% of approx. 43%, leaving only approx.
30% of the original capacity available.
Accordingly, a significantly greater battery capacity must be
selected when configuring the system: A drop to approx. 50%
is compensated for by selecting 1/approx. 0.5 = approx.
double the battery capacity (than required according to the
table for the relevant load current and the relevant buffering
time). Available capacity of approx. 43% is compensated for
by selecting 1/approx. 0.43 = approx. 2.33 times the battery
capacity. Available capacity of approx. 30% is compensated
for by selecting 1/approx. 0.3 = approx. 3.33 times the battery
capacity.
Load current Battery module 1.2 Ah
(6EP1935-6MC01) Battery module 3.2 Ah
(6EP1935-6MD11) Battery module 7 Ah
(6EP1935-6ME21) Battery module 12 Ah
(6EP1935-6MF01) Battery module 2.5 Ah
(6EP1935-6MD31)
1 A 34.5 min 2.6 h 5.4 h 9 h 2 h
2 A 15 min 1 h 2.6 h 4.6 h 1 h
3 A 9 min 39.3 min 1.6 h 2.9 h 37.5 min
4 A 6.5 min 27.1 min 1.2 h 2.2 h 27 min
6 A 3.5 min 17.5 min 41 min 1.2 h 17.6 min
8 A -12.1 min 28.6 min 53.3 min 12.5 min
10 A -9 min 21.8 min 43.5 min 8.8 min
12 A - - 17.3 min 33.3 min 6.8 min
14 A - - 15.1 min 27.5 min 5.1 min
16 A - - 12.5 min 23.8 min 4.3 min
20 A - - 9.1 min 20.1 min -
25 A ---12.6 min -
30 A ---9.1 min -
ST80_2013_EN_Kap05.book Seite 179 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
DC UPS with battery modules
DC UPS with battery modules
5/180 Siemens ST 80 / ST PC · 2013
Overview (continued)
5
Recommendation:
Instead of installing double the battery capacity to cope with
battery aging, regular battery replacement midway through
the expected service life (reduction of capacity to approx.
50%) can be more advisable for the following reasons: Until
the middle (or somewhat past the middle) of the anticipated
battery service life is reached, the capacity does not drop
below 100 %. If the battery is replaced on a regular basis after
reaching half of the anticipated service life, only single
(instead of double) battery capacity must be installed
( neutral price in terms of battery module costs, but only
half of the space requirement).
When swapped after half of the service life, the large scatter
range of the residual capacity, which is not defined in more
detail by battery manufacturers, can be avoided at the end of
the service life (after the full time, many batteries are over or
under the average of 50 % remaining capacity; this means
that even if double the capacity is installed, the effect of aging
at the end of the service life is not reliably compensated for,
but only typically). If the battery is swapped after half of the
anticipated service life, the projected buffering time is much
more reliably adhered to.
For batteries stored in a cool place below +25 °C and for no
longer than approx. 4 months, the following service life can
usually be assumed, highly dependent on the battery temper-
ature):
In normal cases (installation in the coolest location in the control
cabinet at approx. +30 °C), the battery should be replaced with
single installed battery capacity in accordance with the selection
table after 1 year of operation!
On the DC UPS module 40 A, at least 2 battery modules of
7 Ah or higher must be connected in parallel for output
currents > 30 A. When connecting battery modules in parallel,
you must ensure identical capacity and aging.
After a power failure, and at the end of the selected buffering
time, the battery module is disconnected electronically from
the loads as soon as the 24 V input voltage returns either
automatically or by opening the On/Off control circuit, and
quickly recharged with the charge current of the relevant
DC UPS module (with I-U charge characteristic: initially
constant current I for fast charging, and changeover to
constant voltage U to maintain the charge when the battery
is almost full).
Battery
temperature Drop to
approx. 50%
of residual
capacity
Recommenda-
tion: Replace
(at 100% of
residual
capacity)
all
Alternative
recommendation
+20 °C 4years 2 years
+30 °C 2years 1 year
+40 °C 1year 0.5 years Install double
capacity and
replace
1 x per year
More information
You can select the appropriate power supply quickly and easily
using the SITOP Selection Tool:
http://www.siemens.com/sitop-selection-tool
ST80_2013_EN_Kap05.book Seite 180 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
DC UPS with battery modules
DC UPS module 6 A
DC UPS module 15 A
5/181
Siemens ST 80 / ST PC · 2013
SITOP DC UPS module 6 A
Compact design, only 50 mm wide
Simple DIN rail mounting
Completely uninterruptible mains buffering through immediate
electronic connection of the battery as soon as the DC UPS
input voltage falls below the value set by means of
DIP switches.
High level of safety and availability through monitoring of
operational readiness, battery supply line, battery aging
(message "Battery replacement necessary") and battery
charge (message "Battery charged >85 %")
Support for automatic warm restart of industrial PCs through
selectable shutdown characteristics.
Optionally with serial or USB interface.
SW tool available for download from
http://www.siemens.com/sitop
Executes under Windows NT4.0, Windows 2000 and
Windows XP.
Ordering data
Order No.
SITOP DC UPS module 15 A
Compact design, only 50 mm wide
Completely uninterruptible mains buffering through immediate
electronic connection of the battery as soon as the DC UPS
input voltage falls below the value set by means of
DIP switches.
High level of safety and availability through monitoring of
operational readiness, battery supply line, battery aging
(message "Battery replacement necessary") and battery
charge (message "Battery charged >85%")
Support for automatic warm restart of industrial PCs through
selectable shutdown characteristics.
Optionally with serial or USB interface.
SW tool available for download from
http://www.siemens.com/sitop
Executes under Windows NT4.0, Windows 2000 and
Windows XP.
Ordering data
Order No.
SITOP DC UPS module 6 A 6EP1931-2DC21
With serial interface 6EP1931-2DC31
With USB interface 6EP1931-2DC42
SITOP DC UPS module 15 A 6EP1931-2EC21
• With serial interface 6EP1931-2EC31
• With USB interface 6EP1931-2EC42
SIPLUS PS DC UPS module 15 A 6AG1931-2EC21-2AA0
(Extended temperature range
-25...+6C)
ST80_2013_EN_Kap05.book Seite 181 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
DC UPS with battery modules
DC UPS module 40 A
Battery module 1.2 Ah
5/182 Siemens ST 80 / ST PC · 2013
5
SITOP DC UPS module 40 A
Compact design, only 102 mm wide
Completely uninterruptible mains buffering through immediate
electronic connection of the battery as soon as the DC UPS
input voltage falls below the value set by means of
DIP switches.
High level of safety and availability through monitoring of
operational readiness, battery supply line, battery aging
(message "Battery replacement necessary") and battery
charge (message "Battery charged >85 %")
Support for automatic warm restart of industrial PCs through
selectable shutdown characteristics.
Optionally with USB interface.
SW tool available for download from
http://www.siemens.com/sitop
Executes under Windows NT4.0, Windows 2000 and
Windows XP.
Ordering data
Order No.
Battery module 1.2 Ah
Battery module for DC UPS module 6 A
It has two maintenance-free, closed lead-acid batteries
(from the same lot) which are installed in a holder and
connected in series with corrosion-resistant lead-calcium
high-performance grid plates and glass fiber.
Completely prewired with battery retainer and terminals
Low self-discharge rate of approximately 3 % per month
(at +20 °C)
Ordering data
Order No.
SITOP DC UPS module 40 A 6EP1931-2FC21
With USB interface 6EP1931-2FC42
SIPLUS PS DC UPS module 40 A 6AG1931-2FC21-7AA0
(extended temperature range
+25 A ... +70 A °C and medial
loading)
Battery module 24 V/1.2 Ah 6EP1935-6MC01
for DC UPS module 6 A
ST80_2013_EN_Kap05.book Seite 182 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
DC UPS with battery modules
Battery module 2.5 Ah
Battery module 3.2 Ah
5/183
Siemens ST 80 / ST PC · 2013
Battery module 24 V/2.5 Ah
High-temperature battery module for DC UPS module
6 A and 15 A
It has two maintenance-free, closed pure lead-acid batteries
(from the same lot), which are installed in a holder and
connected in series.
Completely prewired with battery retainer and terminals
Low self-discharge rate of approximately 3 % per month
(at +20 °C)
Ordering data
Order No.
Battery module 24 V/3.2 Ah
Battery module for DC UPS module 6 A and 15 A
It has two maintenance-free, closed lead-acid batteries
(from the same lot) which are installed in a holder and
connected in series with corrosion-resistant lead-calcium
high-performance grid plates and glass fiber.
Complete with battery retainer and terminals
Low self-discharge rate of approximately 3 % per month
(at +20 °C)
Ordering data
Order No.
Battery module 24 V/2.5 Ah 6EP1935-6MD31
for DC UPS module 15 A
Battery module 24 V/3.2 Ah 6EP1935-6MD11
for DC UPS module 15 A
ST80_2013_EN_Kap05.book Seite 183 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
DC UPS with battery modules
Battery module 7 Ah
Battery module 12 Ah
5/184 Siemens ST 80 / ST PC · 2013
5
Battery module 7 Ah
Battery module for DC UPS module 6 A, 15 A and DC UPS
module 40 A (for > 30 to 40 A, 2 units are required in parallel)
It has two maintenance-free, closed lead-acid batteries
(from the same lot) which are installed in a holder and
connected in series with corrosion-resistant lead-calcium
high-performance grid plates and glass fiber.
Completely pre-wired with terminals and battery retainer
Low self-discharge rate of approximately 3% per month
(at +20 °C)
Ordering data
Order No.
Battery module 12 Ah
Battery module for DC UPS module 6 A, 15 A and DC UPS
module 40 A (for > 30 to 40 A, 2 units are required in parallel)
It has two maintenance-free, closed lead-acid batteries
(from the same lot) which are installed in a holder and
connected in series with corrosion-resistant lead-calcium
high-performance grid plates and glass fiber.
Completely pre-wired with terminals and battery retainer
Low self-discharge rate of approximately 3% per month
(at +20 °C)
Ordering data
Order No.
Battery module 24 V/7 Ah 6EP1935-6ME21
for DC UPS module 6 A,
15 A and 40 A
Battery module 24 V/12 Ah 6EP1935-6MF01
for DC UPS module 6 A,
15 A and 40 A
ST80_2013_EN_Kap05.book Seite 184 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
MASTERGUARD power supply
MASTERGUARD power supply
5/185
Siemens ST 80 / ST PC · 2013
Overview
MASTERGUARD UPS
The A-19 and EI-19 series of Masterguard offer effective online
protection against all kinds of power supply disturbances
Genuine online operating principle, i.e. complete discon-
nection of the load from the irregularities of the line power
supply
19" compact modules
Simple operation and functional indication of operating states
and load stages
MASTERGUARD UPS Series A-19/EI-19
Permanent double-converter technology evens out any
irregularity in the power supply and offers totally uninterrupted
protection
Easily configurable for use in 19" cabinets thanks to battery
expansions and universal slide rail units
With a height of just 2 HU for the A-19 series and 3 HU for the
EI-19 series and with power-regulated fan and functional
display, these units are ideal where space is limited.
For communication, a choice can be made between serial and
USB interface and, in addition, a network connection of the
UPS can be set up by means of an SNMP plug-in card for the
communication slot.
Standard configuration
MASTERGUARD UPS Series A-19
• A700-19
Output: 700 VA; integrated battery: 6 min.
• A1000-19
Output: 1000 VA; integrated battery: 7 min.
• A2000-19
Output: 2000 VA
• A3000-19
Output: 3000 A
Battery pack for MASTERGUARD Series A-19
BPA 1000-19
for UPS A1000-19 (max. 2 BP)
BPA 3000-19
for UPS A2000-19 (max. 5 BP) and UPS A3000-19 (max. 5 BP)
Accessories
Slide rail unit 2 HU 330-580 mm
Slide rail unit 2 HU 575-855 mm
Standard configuration
MASTERGUARD UPS Series El-19
•EI-19
Output: 6000 VA
Battery pack for MASTERGUARD Series EI-19
•BPEI-19
Accessories
Slide rail unit 3 HU 330-580 mm
Slide rail unit 3 HU 575-855 mm
ManageUPS SNMP adapter card
MopUPS shutdown software
for Intel operating systems (Windows, Linux, Solaris for Intel)
for Risc operating systems (Solaris SPARC, HPUX, AIX)
More information
http://www.masterguard.de
Sales contact:
MASTERGUARD GmbH
Mr. Willi Brinkmann
Phone: +49 9131 6300 248
Fax: +49 9131 6300 271
E-mail: willi.brinkmann@masterguard.de
Information hotline: +49 180-532 37 51
Service contact:
MASTERGUARD GmbH
Mr. Alexander Zink
Phone: +49 9131 6300 218
Fax: +49 9131 6300 281
E-mail: alexander.zink@masterguard.de
Support line: +49 180-522 10 96
ST80_2013_EN_Kap05.book Seite 185 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — Industrial Ethernet
Connection options to SIMATIC IPCs
5/186 Siemens ST 80 / ST PC · 2013
5
Overview
The operating systems listed in the table refer exclusively to the
communication products specified! Please refer to the description of the relevant IPC for the operating system that is
available and has been released for that IPC.
Connection options of Industrial Ethernet CPs to PG/PC/IPC
Embedded Systems
Communication
hardware
Communication
software
Operating system environment of the
communication software
SIMATIC Industrial PC/
Field PG
Op.
sys.
SIMATIC
Industrial-PC
Windows 7 Professional /
Ultimate
Windows Server 2008 R2
Windows Server 2008 +
SP1/2
Vista Business /
Ultimate + SP1/2
Windows XP Pro + SP3
Windows Server 2003
R2 / SP2
other operating systems
Field PG M3
SIMATIC IPC847C
SIMATIC IPC547C/D
SIMATIC IPC627C
SIMATIC IPC827C
SIMATIC IPC427C
Windows XP Embedded +
SP1/SP2/FP 2007
SIMATIC IPC427C,
SIMATIC HMI IPC477C
SIMATIC HMI IPC677C
SIMATIC IPC627C
SIMATIC S7 modular
Embedded Controller
CPs and software for Industrial Ethernet
CP 1613 A2
(PCI 32 Bit)
HARDNET-IE S7
(S7-1613)
••••••
--
••••
-
-
••
-
HARDNET-IE S7
REDCONNECT 3)
••••••
--
••
4)5)
-
-4)5) 4)5) -
S7 OPC Redundancy for
Industrial Ethernet -
------
••••
-
-
••
-
CP 1623
(PCIe x1)
HARDNET-IE S7
(S7-1613)
••••••
--
••
5)
-
- 5) 5) -
HARDNET-IE S7
REDCONNECT 3)
••••••
--
5) 5) 4)5)
-
-4)5) 4)5) -
S7 OPC Redundancy for
Industrial Ethernet -
------
••••
-
-5)
-
CP 1628
(PCIe x1)
HARDNET-IE S7
(S7-1613)
••
------
••
5)
-
- 5) 5) -
HARDNET-IE S7
REDCONNECT 3)
••
------
5) 5) 4)5)
-
-4)5) 4)5) -
S7 OPC Redundancy for
Industrial Ethernet -
------
••••
-
-5)
-
CP 1612 A2
(PCI 32 Bit) SOFTNET-IE S7
••••••
--
••••
-
-
••
-
SOFTNET-IE S7 Lean
••••••
--
••••
-
-
••
-
SOFTNET-IE PG
••••••
--
••••
-
-
••
-
S7 OPC Redundancy for
Industrial Ethernet -
------
••••
-
-
••
-
SIMATIC PG/PC
with integral
Ethernet
interface
SOFTNET-IE S7
••••••
-
•••••••••••
SOFTNET-IE S7 Lean
••••••
-
•••••••••••
SOFTNET-IE PG
••••••
-
•••••••••••
S7 OPC Redundancy for
Industrial Ethernet -
-----
•••••••••••
CPs and software for PROFINET
CP 1616 1)
(PCI 32 Bit) HARDNET PN IO DK
(DK-16xx PN IO) 1)
---
--○○○○--○○-
CP 1604 1)
(PCI-104) HARDNET PN IO DK
(DK-16xx PN IO) 1)
---
------
2) 2) ---
SIMATIC PG/PC
with integral
Ethernet
interface
SOFTNET PN IO
••••••
-
•••••••••••
1) Use of these CPs requires porting of the Development Kit DK-16xx PN IO to the relevant ope-
rating system environment. You can order the DK-16xx PN IO at www.siemens.com/simatic-net/
dk16xx on the Internet. It contains sample software for Linux Suse 12 and Windows XP Pro-
fessional. For IRT operation an exclusive interrupt is necessary; this is not available in all slots.
The additional use of CP 1616/CP 1604 is not approved for SIMATIC Industrial PC versions and
integrated PROFINET interface.
2) possible with restrictions, if necessary, depending on memory expansion and processor capacity
3) requires at least 2 PCI or 2 PCIe slots (4-way redundancy requires 4 free PCI or 4 PCIe slots!);
hybrid configurations with CP 1613 A2 (PCI) and CP 1623 (PCIe) are possible,
depending on PC expansion
4) without 4-way redundancy as there are only 2 slots
5) depending on the slots of the selected PC version
Notes
- Please always note the supplementary conditions for the specified
SIMATIC NET products that you can view on the Internet pages
shown below.
- for further details on XP embedded, see
http://support.automation.siemens.com/WW/view/en/ 21661049
- further details on system requirements and operating environments
can be found in the Readme file of the communication products on
the SIMATIC NET PC Software V8.1 CD
- Updates and supplements to the catalog entries, as well as the abo-
ve tables can be viewed at
http://www.siemens.com/simatic-net/ik-info
-
suitable
not suitable
suitable under
certain condi-
tions
*B,.B;;B
ST80_2013_EN_Kap05.book Seite 186 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — Industrial Ethernet
CP 1604
5/187
Siemens ST 80 / ST PC · 2013
Overview
PCI-104 module for connecting PCI-104 systems to
PROFINET IO
Full/half duplex with autonegotiation
With Ethernet real-time ASIC ERTEC 400
Integral 4-port real-time switch
Communication services:
- PROFINET IO controller and/or PROFINET IO device
- Support of IRT in motion control applications
- Support of PROFIenergy functionality
High performance through direct memory access
Integration in network management systems through the
support of SNMP
Comprehensive diagnostics possibilities for installation,
start-up and operation of the module
Powerful configuration tools are included in delivery of module
Ordering data
Order No. Order No.
More information
The DK-16xx PN IO development kit can be found
on the Internet at:
http://www.siemens.com/simatic-net/dk16xx
*B,.B;;B
,7663*2323&053317&3
8'3
,62
CP 1604
communications processor 6GK1160-4AA01
PCI-104 card (32-bit) with
ASIC ERTEC 400 for connecting
PCI-104 systems to PROFINET IO
with 4-port real-time switch (RJ45);
incl. IO-Base software for
PROFINET IO-Controller and
NCM PC; single license for one
installation, runtime software,
software and electronic manual on
CD-ROM, Class A, for 32-bit
Windows XP Professional and
Windows 7;
other operating systems using
DK-16xx PN IO Development Kit
German/English
CP 1604 Microbox Package 6GK1160-4AU01
Package for implementing
the CP 1604 in the
SIMATIC Microbox PC; comprising
the CP 1604, connection board,
power supply and expansion racks
for Microbox PC; for use with Devel-
opment Kit DK-16xx PN IO; NCM PC
Accessories
Connection board for CP 1604 6GK1160-4AC00
Connection board for CP 1604 with
four RJ45 sockets incl. connecting
cable
Power supply for CP 1604 6GK1160-4AP00
Redundant power supply for
CP 1604 for operating the integral
4-port switch of the CP 1604 with
the PC-104 system switched off;
includes connecting cable
Development Kit DK-16xx PN IO See http://www.siemens.com/
simatic-net/dk16xx
Software Development Kit for
CP 1616/CP 1604;
driver and IO-Base software for
CP 1616/CP 1604 as PN IO control-
ler and PN IO device in source code
for transfer to other PC-based oper-
ating systems; incl. executable
sample code for SUSE Linux 10,
Windows XP Professional and
Windows 7
IE TP Cord RJ45/RJ45
TP cable 4 x 2
with 2 RJ45 connectors
0.5 m 6XV1870-3QE50
•1 m 6XV1870-3QH10
•2 m 6XV1870-3QH20
•6 m 6XV1870-3QH60
• 10 m 6XV1870-3QN10
SCALANCE X204IRT 6GK5204-0BA00-2BA3
Managed Industrial Ethernet
switches; isochronous real time,
LED diagnostics, error signaling
contact with SET button,
redundant power supply
4 x 10/100 Mbit/s RJ45 ports
ST80_2013_EN_Kap05.book Seite 187 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — Industrial Ethernet
CP 1616
5/188 Siemens ST 80 / ST PC · 2013
5
Overview
PCI module for connecting PCs and SIMATIC PGs/PCs
to PROFINET IO (Universal Keyed 3.3 V and 5 V;
33 MHz/66 MHz; 32-bit, runs in 64-bit PCI-X systems)
Full/half duplex with autonegotiation
With Ethernet real-time ASIC ERTEC 400
Integral 4-port real-time switch
Communication services:
- PROFINET IO controller and/or PROFINET IO device
- Support of IRT in motion control applications
High performance through direct memory access
Integration in network management systems through the
support of SNMP
Comprehensive diagnostics possibilities for installation,
start-up and operation of the module
Powerful configuration tools are part of the scope of delivery
of the module
Ordering data
Order No. Order No.
More information
The DK-16xx PN IO development kit can be found
on the Internet at:
http://www.siemens.com/simatic-net/dk16xx
*B,.B;;B
,7663*2323&053317&3
8'3
,62
CP 1616
communications processor 6GK1161-6AA02
PCI Card (32 bit; 3.3/5 V universal
keyed) with ASIC ERTEC 400 for
connecting PCs to PROFINET IO
with 4-Port-Real-Time-Switch
(RJ45); incl. IO Base Software for
PROFINET IO Controller and
NCM PC; single license for one
installation, runtime software,
software and electronic manual
on CD-ROM, Class A, for 32-bit
Windows XP Professional and
Windows 7; other operating systems
via Development Kit DK-16xx PN IO;
German/English
Accessories
Development Kit DK-16xx PN IO See http://www.siemens.com/
simatic-net/dk16xx
Software development kit for
CP 1616/CP 1604;
driver and IO-Base software for
CP 1616/CP 1604 as PN IO control-
ler and IO device in source code for
transfer to other PC-based operat-
ing systems; including executable
example code for SUSE Linux 10,
Windows XP Professional and
Windows 7
IE TP Cord RJ45/RJ45
TP cable 4 x 2
with 2 RJ45 connectors
0.5 m 6XV1870-3QE50
•1 m 6XV1870-3QH10
•2 m 6XV1870-3QH20
•6 m 6XV1870-3QH60
• 10 m 6XV1870-3QN10
SCALANCE X204IRT 6GK5204-0BA00-2BA3
Managed Industrial Ethernet
switches; isochronous real time,
LED diagnostics, error signaling
contact with SET button,
redundant power supply
4 x 10/100 Mbit/s RJ45 ports
ST80_2013_EN_Kap05.book Seite 188 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — Industrial Ethernet
CP 1612 A2
5/189
Siemens ST 80 / ST PC · 2013
Overview
PCI card (32 bit; 33 MHz/66 MHz; 3.3 V/5 V Universal Key)
for the connection of PG/PC to Industrial Ethernet
1 x 10/100/1000 Mbit/s RJ45 port, electrical
Automatic data transmission rate detection
(10/100/1000 Mbit/s), with autosensing and autocrossover
function
Communication services via
-PROFINET
- ISO or TCP/IP transport protocol
- PG/OP communication
- S7 communication
- Open communication (SEND/RECEIVE)
Designed for use in industrial environments
The appropriate OPC servers and configuration tools are
included in the scope of supply of the respective communi-
cation software.
Ordering data
Order No. Order No.
*B,.B;;B
,7663*2323&053317&3
8'3
,62
CP 1612 A2
communications processor 6GK1161-2AA01
PCI card (32 bit, 33 MHz/66 MHz;
3.3 V/5 V universal keyed) for con-
nection to Industrial Ethernet
(10/100/1000 Mbit/s) with RJ45
interface, incl. driver for 32-bit
Windows XP Professional SP2/3,
2003 R2 Server SP2, Vista Business/
Ultimate SP1, Windows 2008 Server;
German/English
SOFTNET Security Client V4 6GK1704-1VW04-0AA0
Software for designing secure
IP-based VPN connections from a
programming device/PC to network
segments which are secured by
SCALANCE S in bridge mode;
Single license for 1 installation,
runtime software (German/English),
configuring tool (German/English)
and electronic manual on CD-ROM
(German/English/French/Italian/
Spanish) for 32-bit Windows,
XP Professional + SP1, SP2, SP3;
for 32/64-bit Windows 7 Ultimate/
Business
SOFTNET PN IO
Software for PROFINET IO Controller
with OPC server and NCM PC,
runtime software, software and elec-
tronic manual on CD-ROM, license
key on USB flash drive, Class A
SOFTNET-IE PN IO V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single License for one installation 6GK1704-1HW08-2AA0
SOFTNET PN IO Edition 2008
(V7.1)
For 32-bit
Windows XP Professional SP 2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/
Ultimate SP1; Windows 2008 Server;
English/German
• Single License for one installation 6GK1704-1HW71-3AA0
Software Update Service 6GK1704-1HW00-3AL0
For 1 year with automatic extension;
requirement: current software
version
Upgrade
• From Edition 2006 to
SOFTNET PN IO Edition 2008
or V8.1
6GK1704-1HW00-3AE0
• From V6.0, V6.1, V6.2 or V6.3 to
SOFTNET PN IO Edition 2008 or
V8.1
6GK1704-1HW00-3AE1
ST80_2013_EN_Kap05.book Seite 189 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — Industrial Ethernet
CP 1612 A2
5/190 Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
5
SOFTNET S7
for Industrial Ethernet
Software for S7 and open communi-
cation, incl. OPC server, PG/OP
communication, and NCM PC,
runtime software, software and
electronic manual on CD-ROM,
license key on a USB stick, Class A
SOFTNET-IE S7 V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2;
German/English
Up to 64 connections
Single License for one installation 6GK1704-1CW08-2AA0
SOFTNET S7 Edition 2008 (V7.1)
for Industrial Ethernet
For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/
Ultimate SP1; Windows 2008 Server;
English/German
Up to 64 connections
Single License for one installation 6GK1704-1CW71-3AA0
Software Update Service 6GK1704-1CW00-3AL0
For 1 year with automatic extension;
requirement: current software ver-
sion
Upgrade
From Edition 2006 to
Edition 2008 or V8.1 6GK1704-1CW00-3AE0
• From V6.0, V6.1, V6.2 or V6.3 to
Edition 2008 or V8.1 6GK1704-1CW00-3AE1
SOFTNET-IE S7 Lean Edition V8.2
Up to eight connections
Single License for one installation 6GK1704-1LW08-2AA0
SOFTNET-S7 Lean Edition 2008
(V7.1) for Industrial Ethernet
Up to eight connections
Single License for one installation 6GK1704-1LW71-3AA0
Software Update Service 6GK1704-1LW00-3AL0
For 1 year with automatic extension;
requirement: current software
version
Upgrade
From Edition 2006 to
Edition 2008 or V8.1 6GK1704-1LW00-3AE0
• From V6.0, V6.1, V6.2 or V6.3 to
Edition 2008 or V8.1 6GK1704-1LW00-3AE1
SOFTNET-IE PG
for Industrial Ethernet
Software for PG/OP communication,
runtime software, software and elec-
tronic manual on CD-ROM, license
key on USB flash drive, Class A
SOFTNET-IE PG V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2;
German/English
• Single License for one installation 6GK1704-1PW08-2AA0
SOFTNET-PG Edition 2008 (V7.1)
for Industrial Ethernet
For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/
Ultimate SP1; Windows 2008 Server;
English/German
• Single License for one installation 6GK1704-1PW71-3AA0
Software update 6GK1704-1PW00-3AL0
For 1 year with automatic extension;
requirement: current software ver-
sion
Upgrade
• From Edition 2006 to
Edition 2008 or V8.1 6GK1704-1PW00-3AE0
• From V6.0, V6.1, V6.2 or V6.3 to
Edition 2008 or V8.1 6GK1704-1PW00-3AE1
IE TP Cord RJ45/RJ45
TP cable 4 x 2
with 2 RJ45 connectors
0.5 m 6XV1870-3QE50
•1 m 6XV1870-3QH10
•2 m 6XV1870-3QH20
•6 m 6XV1870-3QH60
• 10 m 6XV1870-3QN10
Software Update Service 6GK1706-0HB00-3AL0
For 1 year with automatic extension;
requirement: current software ver-
sion
Upgrade
• From Edition 2006 and higher to
Edition 2008, single license 6GK1706-0HB00-3AE0
• From V6.0 to Edition 2008,
single license 6GK1706-0HB00-3AE1
ST80_2013_EN_Kap05.book Seite 190 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — Industrial Ethernet
CP 1613 A2
5/191
Siemens ST 80 / ST PC · 2013
Overview
PCI card (32 bit; 33 MHz/66 MHz; 3.3 V/5 V universal key) with
microprocessor for connection of PG/PC to Industrial Ethernet
with 10/100 Mbit/s Autosensing/Autonegotiation
Communication services using
- Open IE communication via TCP/IP and UDP)
- ISO transport protocol
- PG/OP communication
- S7 communication
- Open communication (SEND/RECEIVE)
15-pole ITP connection
RJ45 connection
Time synchronization
ISO and TCP/IP transport protocol onboard
SNMP-supported diagnostics
The appropriate OPC server and configuration tools are
included in the respective scope of supply of the communi-
cation software
Ordering data
Order No.
1)
also S5-compatible communication
*B,.B;;B
,7663*2323&053317&3
8'3
,62
CP 1613 A2
communications processor 6GK1161-3AA01
PCI card (32-bit, 33 MHz/66 MHz;
3.3 V/5 V universal keyed) for
connection to Industrial Ethernet
(10/100 Mbit/s) with ITP and RJ45
connection over HARDNET-IE S7/
S7-1613 and S7-REDCONNECT,
for operating system support see
SIMATIC NET Software
HARDNET-IE S7
for Industrial Ethernet
Software for S7 and open communi-
cation, incl. PG/OP communication,
OPC server and NCM PC; up to
120 connections, runtime software,
software and electronic manual on
CD-ROM, license key on USB stick,
Class A; for CP 1613/CP 1613 A2/
CP 1623/CP 1628;
HARDNET-IE S7 V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single License for one installation 6GK1716-1CB08-2AA0
S7-1613 Edition 2008 (V7.1)
For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/
Ultimate SP1; Windows 2008 Server;
English/German
• Single License for one installation 6GK1716-1CB71-3AA0
Software Update Service 6GK1716-1CB00-3AL0
For 1 year with automatic extension;
requirement: current software
version
Upgrade
• S7-1613, Edition 2006 or higher,
to S7-1613 Edition 2008 or
HARDNET-IE S7 V8.1
6GK1716-1CB00-3AE0
from S7-1613 V6.0, V6.1, V6.2 or
V6.3 to S7-1613 Edition 2008 or
HARDNET-IE S7 V8.1
6GK1716-1CB00-3AE1
IE TP Cord RJ45/RJ45
TP cable 4 x 2
with 2 RJ45 connectors
0.5 m 6XV1870-3QE50
•1 m 6XV1870-3QH10
•2 m 6XV1870-3QH20
•6 m 6XV1870-3QH60
• 10 m 6XV1870-3QN10
ST80_2013_EN_Kap05.book Seite 191 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — Industrial Ethernet
CP 1623
5/192 Siemens ST 80 / ST PC · 2013
5
Overview
PCI Express Card (PCIe x1) with an internal microprocessor
for connection of PG/PC to Industrial Ethernet
10/100/1000 Mbit/s
(Autosensing/Autocrossover/Autonegotiation)
Integrated 2-port switch (2 x RJ45 connection)
Communications services via
- Open IE communication (TCP/IP and UDP)
- ISO transport protocol
- PG/OP communication
- S7 communication
- Open communication (SEND/RECEIVE)
Time synchronization
ISO and TCP/IP transport protocol on board
Integration into network management systems through the
support of SNMP (V1)
The appropriate OPC server and configuration tools are
included in the scope of supply of the respective communi-
cation software.
Ordering data
Order No.
*B,.B;;B
,7663*2323&053317&3
8'3
,62
CP 1623
communications processor 6GK1162-3AA00
PCI Express x1 card for connection
to Industrial Ethernet
(10/100/1000 Mbit/s), with 2-port
switch (RJ45) via HARDNET-IE S7/
S7-1613 and S7-REDCONNECT.
For operating system support,
see SIMATIC NET Software
HARDNET-IE S7
for Industrial Ethernet
Software for S7 and open communi-
cation, incl. PG/OP communication,
OPC server and NCM PC; up to
120 connections, runtime software,
software and electronic manual on
CD-ROM, license key on USB stick,
Class A; for CP 1613/CP 1613 A2/
CP 1623/CP 1628;
HARDNET-IE S7 V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single License for one installation 6GK1716-1CB08-2AA0
S7-1613 Edition 2008 (V7.1)
For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/
Ultimate SP1; Windows 2008 Server;
English/German
• Single License for one installation 6GK1716-1CB71-3AA0
Software Update Service 6GK1716-1CB00-3AL0
For 1 year with automatic extension;
requirement: current software ver-
sion
Upgrade
• S7-1613, Edition 2006 or higher,
to S7-1613 Edition 2008 or
HARDNET-IE S7 V8.1
6GK1716-1CB00-3AE0
from S7-1613 V6.0, V6.1, V6.2 or
V6.3 to S7-1613 Edition 2008 or
HARDNET-IE S7 V8.1
6GK1716-1CB00-3AE1
IE TP Cord RJ45/RJ45
TP cable 4 x 2
with 2 RJ45 connectors
0.5 m 6XV1870-3QE50
•1 m 6XV1870-3QH10
•2 m 6XV1870-3QH20
•6 m 6XV1870-3QH60
• 10 m 6XV1870-3QN10
ST80_2013_EN_Kap05.book Seite 192 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — Industrial Ethernet
CP 1628
5/193
Siemens ST 80 / ST PC · 2013
Overview
PCI Express card (PCIe x1) with its own microprocessor
and integrated 2-port switch (2 x RJ45 connection,
10/100/1000 Mbit/s) for the connection of a PG/PC to
Industrial Ethernet
Integrated security mechanisms (e.g. Firewall, VPN)
ISO and TCP/IP transport protocol on board
Communications services via
- Open IE communication (TCP/IP and UDP)
- ISO transport protocol
- PG/OP communication
- S7 communication
- Open communication (SEND/RECEIVE)
Integration into network management systems through the
support of SNMP (V1/V3)
Ordering data
Order No.
1)
Shipment without individual export license is restricted to certain countries.
Export to other countries requires an individual export license that must be
applied for from BIS (Bureau of Industry and Security).
Note: Check the current country list:
http://support.automation.siemens.com/WW/view/en/66627157
More information
You will find more information on the topic of Industrial Security
on the Internet at:
http://www.siemens.com/industrialsecurity
*B,.B;;B
,7663*2323&053317&3
8'3
,62
Communications processor
CP 1628
1)
6GK1162-8AA00
PCI Express x1 card for connection
to Industrial Etherne
t (10/100/1000 Mbps),
with 2-port switch (RJ45) and
integrated security (firewall, VPN)
via HARDNET-IE S7 and
S7-REDCONNECT.
For operating system support,
see SIMATIC NET Software
HARDNET S7
for Industrial Ethernet
Software for S7 and open communi-
cation, incl. PG/OP communication,
OPC server and NCM PC; up to
120 connections, runtime software,
software and electronic manual on
CD-ROM, license key on USB stick,
Class A; for CP 1613/CP 1613 A2/
CP 1623/CP 1628;
HARDNET-IE S7 V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single license for one installation 6GK1716-1CB08-2AA0
Software Update Service 6GK1716-1CB00-3AL0
For one year with automatic
extension;
requirement:
Current software version
Upgrade
• S7-1613, Edition 2006 or higher,
to S7-1613 Edition 2008 or
HARDNET-IE S7 V8.1
6GK1716-1CB00-3AE0
from S7-1613 V6.0, V6.1, V6.2 or
V6.3 to S7-1613 Edition 2008 or
HARDNET-IE S7 V8.1
6GK1716-1CB00-3AE1
IE TP Cord RJ45/RJ45
TP cable 4 x 2
with 2 RJ45 connectors
0.5 m 6XV1870-3QE50
•1 m 6XV1870-3QH10
•2 m 6XV1870-3QH20
•6 m 6XV1870-3QH60
• 10 m 6XV1870-3QN10
ST80_2013_EN_Kap05.book Seite 193 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — Industrial Ethernet
HARDNET-IE S7-REDCONNECT
5/194 Siemens ST 80 / ST PC · 2013
5
Overview
System configuration for S7-REDCONNECT
For connecting PCs over redundant Industrial Ethernet to the
SIMATIC S7-400H
Protected from communication failures arising from a fault in
the double bus or in redundant rings
For redundant Layer 2 or Layer 3 Industrial Ethernet
Can also be implemented in non-redundant networks
No additional programming overhead for the PC and
in H systems
The appropriate OPC server and configuration tools are
included in the scope of supply of the respective communi-
cation software
Enhanced redundancy over 4-way communication
(STEP 7 V5.1 + SP4 and higher)
PC with
2 x CP 1613 A2/CP 1623/CP 1628
and HARDNET-IE
S7-REDCONNECT
H CPU
in single mode
S7-400H
ET 200M
Industrial Ethernet
G_IK10_XX_10048
PROFIBUS
*B,.B;;B
,7663*2323&053317&3
8'3
,62
ST80_2013_EN_Kap05.book Seite 194 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — Industrial Ethernet
HARDNET-IE S7-REDCONNECT
5/195
Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
HARDNET-IE S7-REDCONNECT
Software for fail-safe S7 communi-
cation via redundant networks, incl.
S7 OPC server, HARDNET-IE S7,
runtime software, software and elec-
tronic manual on CD-ROM, license
key on USB stick, Class A;
HARDNET-IE S7-REDCONNECT
V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
Single License for one installation 6GK1716-0HB08-2AA0
S7-REDCONNECT Edition 2008
(V7.1)
For 32-bit
Windows XP Professional SP 2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/Ultimate
SP1; Windows 2008 Server;
English/German
Single License for one installation 6GK1716-0HB71-3AA0
Software Update Service 6GK1716-0HB00-3AL0
For 1 year with automatic extension;
requirement: current software
version
Upgrade
From Edition 2006 to
S7-REDCONNECT Edition 2008
or V8.1
6GK1716-0HB00-3AE0
• From V6.0, V6.1, V6.2 or V6.3 to
S7-REDCONNECT Edition 2008 or
V8.1
6GK1716-0HB00-3AE1
HARDNET-IE
S7-REDCONNECT Power Pack
For expansion from HARDNET-IE S7
to S7-REDCONNECT, single license
for one installation, runtime software,
software and electronic manual on
CD-ROM, license key on USB stick,
Class A;
HARDNET-IE S7-REDCONNECT
Power Pack V8.2 6GK1716-0HB08-2AC0
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2;
German/English;
S7-REDCONNECT Power Pack
Edition 2008 (V7.1) 6GK1716-0HB71-3AC0
For 32-bit
Windows XP Professional SP 2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/
Ultimate SP1; Windows 2008 Server;
English/German
CP 1613 A2
communications processor 6GK1161-3AA01
PCI card (32-bit, 33 MHz/66 MHz;
3.3 V/5 V universal keyed) for
connection to Industrial Ethernet
(10/100 Mbit/s) with ITP and RJ45
connection over HARDNET-IE S7
and S7-REDCONNECT,
for operating system support see
SIMATIC NET Software
CP 1623
communications processor 6GK1162-3AA00
PCI Express x1 card for
connection to Industrial Ethernet
(10/100/1000 Mbit/s), with 2-port
switch (RJ45) via HARDNET-IE S7
and S7-REDCONNECT.
For operating system support,
see SIMATIC NET Software
CP 1628
communications processor 6GK1162-8AA00
PCI Express x1 card for
connection to Industrial Ethernet
(10/100/1000 Mbit/s), with 2-port
switch (RJ45) and integral security
(firewall, VPN) via HARDNET-IE S7
and S7-REDCONNECT.
For operating system support,
see SIMATIC NET software
ST80_2013_EN_Kap05.book Seite 195 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — Industrial Ethernet
SOFTNET for Industrial Ethernet
5/196 Siemens ST 80 / ST PC · 2013
5
Overview
System configuration SOFTNET for Industrial Ethernet
Software for coupling programming devices/workstations to
automation systems
Communication services:
- PG/OP communication
- S7 communication
- Open communication (SEND/RECEIVE)
Can be used with
- Layer 2 Ethernet card (PCI/PCIe)
- Integrated Industrial Ethernet interface, e.g. CP 1612 A2
- Modem (Remote Access Service RAS)
Complete protocol stack as a software package
Increased availability thanks to additional option packages
such as OPC Server Redundancy
z^TZWWGG
jwGZ[ZTX
z^T[WWGG
jwG[[ZTX
S7-1200 G
CSM 1277
otp
zvm{ul{V
ohykul{TplGz^GG
plGz^GvwjGy
zvm{ul{V
ohykul{TplGz^GG
plGz^GvwjGy
p
l
nprXWXWW[\
*B,.B;;B
,7663*2323&053317&3
8'3
,62
ST80_2013_EN_Kap05.book Seite 196 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — Industrial Ethernet
SOFTNET for Industrial Ethernet
5/197
Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
SOFTNET S7
for Industrial Ethernet
Software for S7 and open communi-
cation, incl. OPC server, PG/OP
communication, and NCM PC,
runtime software, software and
electronic manual on CD-ROM,
license key on a USB stick, Class A
SOFTNET-IE S7 V8.2
For 32/64-bit
Windows 7 Professional/Ultimate;
for 64-bit: Windows 2008 Server R2;
German/English
Up to 64 connections
Single License for one installation 6GK1704-1CW08-2AA0
SOFTNET-S7 Edition 2008 (V7.1)
for Industrial Ethernet
For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/Ultimate
SP1; Windows 2008 Server;
English/German
Up to 64 connections
Single License for one installation 6GK1704-1CW71-3AA0
Software Update Service 6GK1704-1CW00-3AL0
For 1 year with automatic extension;
requirement: current software ver-
sion
Upgrade
From Edition 2006 to
Edition 2008 or V8.2 6GK1704-1CW00-3AE0
• From V6.0, V6.1, V6.2 or V6.3 to
Edition 2008 or V8.1 6GK1704-1CW00-3AE1
SOFTNET-IE S7 REDCONNECT
VM V8.2
Software for fail-safe S7 communi-
cation via redundant networks, incl.
S7 OPC server, HARDNET-IE S7,
runtime software, software and
electronic manual on CD-ROM,
license key on USB stick, Class A
for 32/64-bit: Windows 7
Professional/Ultimate;
for 64-bit: Windows 2008 Server R2;
German/English;
Single License for one installation 6GK1704-0HB08-2AA0
SOFTNET-IE S7 Lean Edition V8.2
Up to eight connections
Single License for one installation 6GK1704-1LW08-2AA0
SOFTNET-S7 Lean Edition 2008
(V7.1) for Industrial Ethernet
Up to eight connections
Single License for one installation 6GK1704-1LW71-3AA0
Software Update Service 6GK1704-1LW00-3AL0
For 1 year with automatic extension;
requirement: current software ver-
sion
Upgrade
From Edition 2006 to
Edition 2008 or V8.1 6GK1704-1LW00-3AE0
• From V6.0, V6.1, V6.2 or V6.3 to
Edition 2008 or V8.1 6GK1704-1LW00-3AE1
SOFTNET-PG
for Industrial Ethernet
Software for PG/OP communication,
runtime software, software and elec-
tronic manual on CD-ROM, license
key on USB flash drive, Class A
SOFTNET-IE PG V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2;
German/English
• Single License for one installation 6GK1704-1PW08-2AA0
SOFTNET-PG Edition 2008 (V7.1)
for Industrial Ethernet
For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2; Win-
dows Vista Business/
Ultimate SP1; Windows 2008 Server;
English/German
• Single License for one installation 6GK1704-1PW71-3AA0
Software update 6GK1704-1PW00-3AL0
For 1 year with automatic extension;
requirement: current software
version
Upgrade
• From Edition 2006 to
Edition 2008 or V8.1 6GK1704-1PW00-3AE0
• From V6.0, V6.1, V6.2 or V6.3 to
Edition 2008 or V8.1 6GK1704-1PW00-3AE1
IE S7 OPC Redundancy
Software for redundant OPC servers
in the environment of Industrial
Ethernet software, S7 products,
runtime software, software and
electronic manual on CD-ROM,
license key on USB flash drive,
Class A
IE S7 OPC Redundancy V8.2
For 64-bit:
Windows 2008 Server R2;
German/English
• Single License for one installation 6GK1706-1CW08-2AA0
• Software Update Service
for one year,
with automatic extension;
requirement:
current software version
6GK1706-1CW00-3AL0
ST80_2013_EN_Kap05.book Seite 197 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — Industrial Ethernet
SOFTNET-IE RNA
5/198 Siemens ST 80 / ST PC · 2013
5
Overview
SOFTNET-IE RNA (Redundant Network Access is the software
for connecting a PC to networks with PRP (Parallel Redun-
dancy Protocol in accordance with IEC62439-3) capability
High level of plant availability thanks to duplicate transmission
of frames in two parallel, separate networks
Reconfiguration times in a subnetwork do not affect the propo-
gation time because the frames are transmitted via two
separate networks (bumpless redundancy)
Integration in network management systems through support
for SNMP
Configuring tools are included in the scope of delivery of the
communication software in each case
Ordering data
Order No.
Server with
SOFTNET-IE
RNA
PG/PC/IPC with
SOFTNET-IE RNA
SIMATIC
S7-400 with
CP 443-1RNA
G_IK10_XX_10333
Industrial
Ethernet
(LAN B)
Industrial
Ethernet
(LAN A)
SCALANCE
X204RNA
SIPROTEC
PC
SOFTNET-IE RNA
Software for connecting PCs to
PRP-enabled networks with inte-
grated SNMP, runtime software,
software and electronic manual on
CD-ROM, license key on USB flash
drive, Class A
SOFTNET-IE RNA V8.1
For 32-bit Windows XP;
German/English
• Single License for one installation 6GK1711-1EW08-1AA0
SOFTNET-IE RNA V8.2
For 32/64-bit
Windows 7 Professional/Ultimate;
for 64-bit Windows 2008 Server R2;
German/English
• Single License for one installation 6GK1711-1EW08-2AA0
Software Update Service 6GK1711-1EW00-3AL0
For 1 year with automatic extension;
requirement: current software
version
SCALANCE X-200RNA
Industrial Ethernet
network access points
Industrial Ethernet network access
points with integrated SNMP
access, web diagnostics and
PROFINET diagnostics, for connect-
ing non-PRP-enabled terminal
equipment to PRP networks; incl.
operating instructions, Industrial
Ethernet network manual and con-
figuration software on CD-ROM;
with electrical and optical ports for
glass multimode fiber-optic cable
up to 5 km
SCALANCE X204RNA
with four 100 Mbit/s RJ45 ports 6GK5204-0BA00-2KB2
SCALANCE X204RNA EEC
with two 100 Mbit/s RJ45 ports and
two RJ45/SFP combo ports
6GK5204-0BS00-3LA3
ST80_2013_EN_Kap05.book Seite 198 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — Industrial Ethernet
SOFTNET PN IO
5/199
Siemens ST 80 / ST PC · 2013
Overview
PC with SOFTNET PN IO as PROFINET IO Controller
Software with PROFINET IO Controller function for coupling
PG/PC and IPC with PROFINET IO Devices
Possible applications:
- PC-based control systems
- HMI systems
- Test applications
Communication services:
- PROFINET IO Controller
Can be used with
- Integrated interfaces of SIMATIC PG/PC
- You can find more information about the environment of use
at www.siemens.com/simatic-net/ik-info
Cost-effective solution for the low-end performance range
OPC server for I/O interfacing over PROFINET included in
scope of supply
e.g. S7-300 with
CPU 31x and
CP 343-1
ET 200S with
IM 151-3 PN
PC/IPC with
SOFTNET PN IO
e. g. S7-300 with
CP 342-5 as Slave
PROFINET
Communication
OPC XML DA
as Webservice
G_IK10_XX_10073
PROFINET
PROFIBUS
Industrial Ethernet
ET 200pro
IE/PB Link
PN IO
Internet
Intranet
ET 200S
SIMATIC NET
OPC-Scout
WinCC
OPC-Client
Microsoft Office
OPC-Client
OPC XML
Webclient
PN IO OPC-Server
SOFTNET PN IO
COM/DCOMOPC UA
*B,.B;;B
,7663*2323&053317&3
8'3
,62
ST80_2013_EN_Kap05.book Seite 199 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — Industrial Ethernet
SOFTNET PN IO
5/200 Siemens ST 80 / ST PC · 2013
5
Ordering data
Order No. Order No.
SOFTNET PN IO
Software for PROFINET IO Controller
with OPC server and NCM PC,
runtime software, software and
electronic manual on CD-ROM,
license key on USB flash drive,
Class A
SOFTNET-IE PN IO V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit: Windows 2008 Server R2
German/English
Single License for one installation 6GK1704-1HW08-2AA0
SOFTNET PN IO Edition 2008
(V7.1)
For 32-bit
Windows XP Professional SP 2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/
Ultimate SP1; Windows 2008 Server;
German/English
Single License for one installation 6GK1704-1HW71-3AA0
Software Update Service 6GK1704-1HW00-3AL0
For 1 year with automatic extension;
requirement: current software
version
Upgrade
• From Edition 2006 to
SOFTNET PN IO
Edition 2008 or V8.1
6GK1704-1HW00-3AE0
• From V6.0, V6.1, V6.2 or
V6.3 to SOFTNET PN IO
Edition 2008 or V8.1
6GK1704-1HW00-3AE1
ST80_2013_EN_Kap05.book Seite 200 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — Industrial Ethernet
OPC server for Industrial Ethernet
5/201
Siemens ST 80 / ST PC · 2013
Overview
System integration with OPC server
OPC (Openness, Productivity & Collaboration) is a
standardized, open, and vendor-independent interface that is
widely used in automation.
A fundamental distinction is made between the classic OPC and
its consistent further development OPC UA (Unified Archi-
tecture). Smooth migration to the new OPC UA standard is easily
possible; this offers further value added, such as security. The
SIMATIC NET OPC servers offer the two interfaces OPC UA and
classic OPC for SIMATIC S7 and PROFINET.
The appropriate OPC servers are included in the scope of
supply of the respective communication software
Standardized, open multi-vendor interface
It permits interfacing of OPC-capable Windows
applications to S7-communication, open communication
(SEND/RECEIVE), PROFINET and SNMP.
Increased availability thanks to additional option packages
such as OPC server redundancy
OPC Scout with browser functionality as an OPC client and
OCX Data Control/.NET Data Control for simple OPC client
creation
OPC XML DA
as Web service
SIMATIC S5
(SEND/RECEIVE only)
SNMP
OPC server
PN IO OPC serverS/R OPC server
DP OPC server
FMS OPC server
DP protocol
FMS protocol
S7 OPC server
S7 communication
Open
communication
(SEND/RECEIVE)
PC/Windows PC
SIMATIC NET
OPC-Scout
WinCC
OPC-Client
Microsoft Office
OPC-Client
OPC XML
Webclient
Internet
Intranet
PROFINET
SNMPPROFINET
COM/DCOM
OPC UA
G_IK10_XX 10103
Industrial Ethernet
S7-400
S7-300
SIMATIC S5
ET 200pro
PROFIBUS
PC
PC
S7-1200
S7-1200
ST80_2013_EN_Kap05.book Seite 201 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — Industrial Ethernet
OPC server for Industrial Ethernet
5/202 Siemens ST 80 / ST PC · 2013
5
Ordering data
Order No. Order No.
SNMP OPC server See SNMP OPC server
Status monitoring of SNMP-capable
devices in any OPC client systems;
e.g. SIMATIC WinCC/PCS 7
S7 OPC Redundancy
Software for redundant OPC servers
in the environment of Industrial
Ethernet software, S7 products,
runtime software, software and elec-
tronic manual on CD-ROM, license
key on USB flash drive, Class A
S7 OPC Redundancy V8.2
For 64-bit:
Windows 2008 Server R2;
German/English
• Single License for one installation 6GK1706-1CW08-2AA0
Software Update Service 6GK1706-1CW00-3AL0
For 1 year with automatic extension;
requirement: current software
version
ST80_2013_EN_Kap05.book Seite 202 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — Industrial Ethernet
PN CBA OPC server
5/203
Siemens ST 80 / ST PC · 2013
Overview
System integration with the PN CBA OPC server
Access to variables in PROFINET CBA components over the
OPC interface
Use of the objects and symbols defined using the PROFINET
engineering tool SIMATIC iMap and STEP 7
Adding PROFINET functionality to existing installations. This
enables it to be used in parallel with other communication
protocols such as S7 communication with SOFTNET-S7 for
Industrial Ethernet.
OPC Scout as an OPC client with browser functions for the
variables of the PROFINET CBA components
WinCC flexible
OPC client
Microsoft Office
OPC client
SIMATIC NET
OPC Scout
S7 communication
PROFINET
CBA
component
e.g. S7-400
with
CP 443-1 Advanced
PROFINET
CBA
component
PROFINET
IO Device
PROFINET
IO Devices
IPC with
CP 1616/
CP 1604
S7-300 with
CP 343-1,
CP 343-1 Lean
CP 343-1
e.g. S7-300 with
CP 343-1 and
CP 343-5
Data access
Data access via PROFIBUS DP
from viewpoint of PN CBA OPC server
from viewpoint of PN IO OPC server
G_IK10_XX_10122
PROFINET
PROFIBUS DP
Industrial Ethernet
PROFIBUS DP
ET 200S
ET 200pro
SOFTNET-S7
SOFTNET-S7 Lean
S7-1613 SOFTNET PN IOPN CBA OPC-Server
PROFINET IO
PN IO OPC-Server
PROFINET CBA
PN CBA
OPC-Server
S7-OPC-Server
ET 200S
ET 200S
IE/PB
Link
PN IO
ST80_2013_EN_Kap05.book Seite 203 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — Industrial Ethernet
PN CBA OPC server
5/204 Siemens ST 80 / ST PC · 2013
5
Ordering data
Order No.
More information
http://www.siemens.com/cba
PN CBA OPC Server Edition 2008
PROFINET OPC server for CBA;
runtime software, software and
electronic manual on CD-ROM,
license key on USB flash drive,
Class A,
for 32-bit
Windows XP Professional SP 2/3;
Windows 2003 Server R2, SP2;
German/English
Single license for one installation 6GK1706-0HB71-3AA0
Software Update Service for one
year,
with automatic extension;
requirement: Current software
version
6GK1706-0HB00-3AL0
Upgrade from Edition 2006 and
higher to Edition 2008,
single license
6GK1706-0HB00-3AE0
Upgrade from V6.0, V6.1, V6.2 or
V6.3 to Edition 2008,
Single License
6GK1706-0HB00-3AE1
Software iMap V3.0
for configuring
PROFINET CBA
Requirement:
Windows 2000 Prof. with Service
Pack 4 or later or Windows XP
Prof. with Service Pack 1 or later
or Windows 2003 Server
with Service Pack 1 or later;
on PG or PC with Pentium
processor, min. 1 GHz; STEP 7
V5.3 or later with Service Pack 3,
PN OPC Server V6.3 or later
Type of supply:
German, English with electronic
documentation
Single license 6ES7820-0CC04-0YA5
Software Update Service 6ES7820-0CC01-0YX2
• Upgrade to V3.0, single license 6ES7820-0CC04-0YE5
ST80_2013_EN_Kap05.book Seite 204 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — Industrial Ethernet
S7 OPC Redundancy for Industrial Ethernet
5/205
Siemens ST 80 / ST PC · 2013
Overview
OPC (Openness, Productivity & Collaboration) is a
standardized, open, and vendor-independent interface that is
widely used in automation. OPC UA (Unified Architecture) is the
result of consistent further development of this standard, offering
additional functions such as security or redundancy.
S7 OPC Redundancy is a software product compliant with the
OPC UA standard that enables the redundant configuration of
OPC UA servers to SIMATIC S7. The availability of automation
data to operator control and monitoring systems is guaranteed
thanks to the redundant use of OPC UA servers. This requires
neither additional cabling for synchronizing the redundant OPC
UA servers, nor additional programming overhead in the PC.
The OPC UA servers are synchronized via high-performance
Industrial Ethernet network access points at 10/100 and
1000 Mpbs. S7 OPC Redundancy represents an integrated
customer solution for all SIMATIC NET S7 SOFTNET and
HARDNET software products in the automation world.
Ordering data
Order No.
OPC UA
synchronization
HMI
S7 OPC redundancyS7 OPC redundancy
G_IK10_XX_10295
PROFIBUS
Industrial Ethernet
Industrial Ethernet
Station B Station A
S7 OPC Redundancy
Software for redundant OPC servers
in the environment of Industrial
Ethernet software, S7 products,
runtime software, software and elec-
tronic manual on CD-ROM, license
key on USB flash drive, Class A
S7 OPC Redundancy V8.2 for
Industrial Ethernet
For 64-bit:
Windows 2008 Server R2;
German/English
• Single License for one installation 6GK1706-1CW08-2AA0
Software Update Service 6GK1706-1CW00-3AL0
For 1 year with automatic extension;
requirement: current software
version
ST80_2013_EN_Kap05.book Seite 205 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — Industrial Ethernet
SNMP OPC server
5/206 Siemens ST 80 / ST PC · 2013
5
Overview
Status monitoring of SNMP-capable devices in any OPC client
systems; e.g. SIMATIC WinCC/PCS 7
Easy access to SNMP-capable devices over the
OPC interface
Devices without SNMP agents can be monitored using the
ping mechanism
Configuring with STEP 7 or NCM PC
Ready-to-use SNMP diagnostics profiles for Siemens devices,
e.g. SCALANCE X/W
Generation of any SNMP diagnostics profiles by means of the
integral MIB compiler
Easy setup of the monitored devices with the help of an
autodiscovery function
Ordering data
Order No. Order No.
Pumpstation Network
1GBit
Pump Main
Pump Substation 1
Pump Old
S_IK10_XX_00004
SNMP OPC server
Including MIB compiler; single
license for one installation of runtime
software; software and electronic
manual on CD-ROM; license key on
USB stick, Class A;
SNMP OPC Server Basic
Administration of
up to 20 IP addresses
Basic V8.2
for 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2;
Single license for one installation
6GK1706-1NW08-2AA0
Basic 2008 (V7.1)
for 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/Ultimate
SP1; Windows 2008 Server;
Single license for one installation
6GK1706-1NW71-3AA0
Software Update Service SNMP
OPC Server Basic 6GK1706-1NW00-3AL0
For 1 year with automatic extension;
requirement: current software ver-
sion
Upgrade SNMP OPC Server Basic
From Edition 2006 to
Edition 2008 or V8.1 6GK1706-1NW00-3AE0
• From V6.0, V6.1, V6.2 or V6.3 to
Edition 2008 or V8.1 6GK1706-1NW00-3AE1
SNMP OPC Server Extended
Administration of
up to 200 IP addresses
Extended V8.2
for 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit: Windows 2008 Server
R2;
Single license for one installation
6GK1706-1NX08-2AA0
Extended 2008 (V7.1)
for 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/Ultimate
SP1; Windows 2008 Server;
Single license for one installation
6GK1706-1NX71-3AA0
Software Update Service SNMP
OPC Server Extended 6GK1706-1NX00-3AL0
For 1 year with automatic extension;
requirement: current software
version
Upgrade SNMP OPC Server
Extended
• From Edition 2006 to
Edition 2008 or V8.1 6GK1706-1NX00-3AE0
• From V6.0, V6.1, V6.2 or V6.3 to
Edition 2008 or V8.1 6GK1706-1NX00-3AE1
SNMP OPC Server Power Pack
For upgrade from
SNM OPC Server Basic to
SNM OPC Server Extended
Power Pack V8.2 6GK1706-1NX08-2AC0
Power Pack Edition 2008 (V7.1) 6GK1706-1NX71-3AC0
ST80_2013_EN_Kap05.book Seite 206 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — Industrial Ethernet
SINEMA server
5/207
Siemens ST 80 / ST PC · 2013
Overview
SINEMA Server is a web-based network monitoring software that
significantly reduces the response time to communications
problems in industrial networks, and thus avoids downtimes and
saves costs.
Simple operator input even for plant operators or service
personnel, to enable autonomous detection and correction of
communications problems
Graphical representation of industrial networks
(automatic topology detection and layout)
Standardized network documentation
(reports for inventory, availability and utilization)
Simple operation via web browser or via an
HMI/SCADA application, without special IT knowledge
Network data such as network topology and device infor-
mation automatically saved to a database
Low installation and maintenance costs, especially thanks to
the use of pre-installed industrial PCs (Microbox PC)
High degree of flexibility for graphical representation thanks to
automatic and customizable topology views
Monitoring can be adapted to devices and users
Ordering data
Order No.
SINEMA Server Basic V12
Network monitoring software for indus-
trial Ethernet and PROFINET networks,
runtime software, software and elec-
tronic manual on DVD, license key on
USB flash memory;
software for installation on PC hard-
ware with Windows 7 Ultimate/
Enterprise SP1 (32/64-bit),
Windows XP SP3 (32-bit) and
Windows Server 2008 R2 (64-bit);
English/German/French/Chinese.
Other languages possible on request.
• For 50 devices that
can be identified via IP address 6GK1781-1BA12-0AA0
• For 100 devices that
can be identified via IP address 6GK1781-1DA12-0AA0
• For 250 devices that
can be identified via IP address 6GK1781-1JA12-0AA0
• For 500 devices that
can be identified via IP address 6GK1781-1TA12-0AA0
Upgrade SINEMA Server V11 to V12 6GK1781-2AA12-0AA0
ST80_2013_EN_Kap05.book Seite 207 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — PROFIBUS
Connection options to SIMATIC IPCs
5/208 Siemens ST 80 / ST PC · 2013
5
Overview
Connection options of PROFIBUS CPs to PG/PC
Note:
The operating systems listed refer exclusively to the communication
products specified! For the actual operating system that is available and has been released,
please refer to the description of the corresponding IPC.
Embedded Systems
Communication
hardware
Communication
software
Operating system environment of the
communication software
SIMATIC Industrial PC/
Field PG
Op.
sys.
SIMATIC
Industrial PCs 3)
Windows 7 Professional /
Ultimate
Windows Server 2008 R2
Windows Server 2008 +
SP1/2
Vista Business /
Ultimate + SP1/2
Windows XP Pro + SP3
Windows Server 2003 +
SP1/2
Windows Server 2003 R2 /
SP2
other operating systems
Field PG M3
SIMATIC IPC847C
SIMATIC IPC647C
SIMATIC IPC547C,
SIMATIC HMI IPC577D
SIMATIC IPC627C
SIMATIC IPC827C
SIMATIC IPC427C
Windows XP Embedded +
SP1/SP2/FP 2007
SIMATIC IPC427C
SIMATIC HMI IPC477C
SIMATIC HMI IPC677C
SIMATIC IPC627C
SIMATIC S7 modular
Embedded Controller
CPs and software for Industrial Ethernet
CP 5603
(PCI-104)
CP with DP-Base ●●●●●●● - - - - - - - ●●●● - - -
HARDNET-PB DP DK 1)
(DK-5613, DP-base) ○○○○○○○○ - - - - - - ○○○○ - - 5)
HARDNET-PB DP
(DP-5613) ●●●●●●● - - - - - - - ●●●● - - -
HARDNET-PB S7
(S7-5613) ●●●●●●● - - - - - - - ●●●● - - -
S7 OPC Redundancy for
PROFIBUS ----------------
CP 5613 A2,
CP 5614 A2
(PCI 32 Bit)
CP mit DP-Base ●●●●●●● - - ●●●●● - - - - ●● -
HARDNET-PB DP DK 1)
(DK-5613, DP-base) ○-○○-○- -○○-
HARDNET-PB DP
(DP-5613) ●●●●●●● - - ●●●●● - - - - ●● -
HARDNET-PB S7
(S7-5613) ●●●●●●● - - ●●●●● - - - - ●● -
S7 OPC Redundancy for
PROFIBUS - ● - - - - - - - ●●●●● - - - - ●● -
CP 5623,
CP 5624
(PCIe x1)
CP with DP-Base ●●●●●●● - - 4) -● 4) ---- 4) 4) -
HARDNET-PB DP DK 1)
(DK-5613, DP-base) ○-○-○○-○- - 4) 4) -
HARDNET-PB DP
(DP-5613) ●●●●●●● - - 4) -● 4) ---- 4) 4) -
HARDNET-PB S7
(S7-5613) ●●●●●●● - - 4) -● 4) ---- 4) 4) -
S7 OPC Redundancy for
PROFIBUS -------- 4) -● 4) ---- 4) 4) -
CP 5612
(PCI 32 Bit)
SOFTNET-PB DP -----------
SOFTNET-PB DP Slave -----------
SOFTNET-PB S7 -----------
S7 OPC Redundancy for
PROFIBUS -------------
CP 5622
(PCIe x1)
SOFTNET-PB DP ------ 4) -● 4) ---- 4) 4) -
SOFTNET-PB DP Slave ------ 4) -● 4) ---- 4) 4) -
SOFTNET-PB S7 ------ 4) -● 4) ---- 4) 4) -
S7 OPC Redundancy for
PROFIBUS -------- 4) -● 4) ---- 4) 4) -
CP 5512
(Cardbus 32 Bit)
SOFTNET-PB DP ---------------
SOFTNET-PB DP Slave ---------------
SOFTNET-PB S7 ---------------
CP 5711
(USB V2.0)
SOFTNET-PB DP ●●●●●●● - ●●●●●●●●●●●●●
SOFTNET-PB DP Slave ●●●●●●● - ●●●●●●●●●●●●●
SOFTNET-PB S7 ●●●●●●● - ●●●●●●●●●●●●●
S7 OPC Redundancy for
PROFIBUS - - - - - - - ●●●●●●●●●●●●●
SIMATIC PG/PC SOFTNET-PB DP ●●●●●●● - ● 2) 2) -○
2) 2) 2) ●○
2) 2) 2) -
SOFTNET-PB DP Slave ●●●●●●● - ● 2) 2) -○
2) 2) 2) ●○
2) 2) 2) -
SOFTNET-PB S7 ●●●●●●● - ● 2) 2) -○
2) 2) 2) ●○
2) 2) 2) -
S7 OPC Redundancy for
PROFIBUS ------- 2) 2) -○
2) 2) 2) ●○
2) 2) 2) -
1) In order to use these CPs in other operating system environments, it is re-
quired to port HARDNET DP Development Kits (DK-5613) into the respective
operating system. You can request the HARDNET DP DK in the Internet under
www.siemens.com/simatic-net/dk5613.
2) integrated PROFIBUS interface is optional
3) depending on available memory and processor performance there could be
restrictions
4) depending on the slots of the selected PC version
5) EM-PCI 104 expansion module is required
Notes
- Please always note the supplementary conditions for the specified SIMATIC NET products
that you can view on the Internet pages shown below.
- for further details on XP embedded, see
http://support.automation.siemens.com/WW/view/en/ 21661049
- further details on system requirements and operating environments can be found in the
Readme file of the communication products on the SIMATIC NET PC Software CD V8.1
- Updates and supplements to the catalog entries, as well as the above tables can be
viewed at http://www.siemens.com/simatic-net/ik-info
-
suitable
not suitable
suitable under
certain conditions
*B,.B;;B
ST80_2013_EN_Kap05.book Seite 208 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — PROFIBUS
CP 5603
5/209
Siemens ST 80 / ST PC · 2013
Overview
PCI-104 interface card with own microprocessor for
connecting embedded systems with PCI-104 interface to
PROFIBUS at up to 12 Mbit/s
Function compatible with CP 5613 A2
Communication services:
- PROFIBUS DP master Class 1 and 2 or DP slave according
to IEC 61158/61784
- PG/OP communication with STEP 5 and STEP 7
- S7 communication with HARDNET-PB S7 software package
- Open communication (SEND/RECEIVE) based on the
FDL interface
- PROFIBUS FMS according to IEC 61158/61784 with
FMS-5613 software package
Extensive diagnostics options for installation, commissioning
and operation of the module
Event and filter mechanism for reducing the load on the host
CPU
Multiprotocol operation and parallel operation of up to three
CPs
The appropriate OPC server and configuration tools are
included in the scope of delivery of the respective communi-
cation software
Linux-based development kit with driver sources for
integration into "non-Windows" environments
Ordering data
Order No.
*B,.B;;B
663*2323&)06'36'30
CP 5603
communications processor 6GK1560-3AA00
PCI-104 card for connection to
PROFIBUS incl. DP-Base software
with NCM PC; DP-RAM interface for
DP master or DP slave, incl. PG and
FDL protocols; single license for one
installation, runtime software,
software and electronic manual on
CD-ROM, Class A, for operating
system support see SIMATIC NET
software; German/English
Software Upgrade 6GK1561-3AA01-3AE0
For CP 5603, CP 5613 A2 and
CP 5623 to Edition 2008 or V8.1
CP 5603 Microbox Package 6GK1560-3AU00
For use of CP 5603 in
Microbox 420/427B/427C;
consisting of CP 5603 module and
Microbox expansion frame
CP 5603 expansion rack 6GK1560-3AA00-0AU0
For use in Microbox 420/427B/427C
with mounting material
CP 5603 mEC Package 6GK1560-3AE00
For use of CP 5603
in SIMATIC S7-MEC;
consisting of CP 5603 and with-
drawable unit for CP 5603 for instal-
lation in the EM PCI-104 expansion
module of the SIMATIC S7-MEC
CP 5603 insert plate 6GK1560-3AA00-0AE0
Metal plate with RS485 cutout
for inserting for the S7 modular
embedded controller
HARDNET-PB DP
Development Kit See http://www.siemens.com/
simatic-net/dk5613
HARDNET-PB DP Development Kit
software for CP 5603, CP 5613,
CP 5613 A2, CP 5623, CP 5613 FO,
CP 5614, CP 5614 A2, CP 5624; for
integration into other operating sys-
tem environments on systems with a
PCI slot
ST80_2013_EN_Kap05.book Seite 209 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — PROFIBUS
CP 5603
5/210 Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
5
More information
You can find the HARDNET-PB DP Development Kit on the
Internet at:
http://www.siemens.com/simatic-net/dk5613
HARDNET-PB DP
Software for DP, incl. PG and FDL
protocol, OPC server and NCM PC;
runtime software, software and elec-
tronic manual on CD-ROM, license
key on USB flash drive, Class A, for
CP 5603, CP 5613 A2, CP 5623,
CP 5614 A2, CP 5624;
HARDNET-PB DP V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
Single License for one installation 6GK1713-5DB08-2AA0
DP-5613 Edition 2008
For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/
Ultimate SP1; Windows 2008 Server;
English/German
Single License for one installation 6GK1713-5DB71-3AA0
Software Update Service 6GK1713-5DB00-3AL0
For 1 year with automatic extension;
requirement: current software ver-
sion
Upgrade
From Edition 2006 or 2007
to DP-5613 Edition 2008 or
HARDNET-PB DP V8.1
6GK1713-5DB00-3AE0
• From V6.0, V6.1, V6.2 or V6.3
to DP-5613 Edition 2008 or
HARDNET-PB DP V8.1
6GK1713-5DB00-3AE1
HARDNET-PB S7
Software for S7 communication, incl.
PG and FDL protocol, OPC server
and NCM PC; runtime software,
software and electronic manual on
USB flash drive, Class A, for
CP 5603, CP 5613 A2, CP 5623,
CP 5614 A2, CP 5624;
HARDNET-PB S7 V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
Single License for one installation 6GK1713-5CB08-2AA0
S7-5613 Edition 2008
For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/
Ultimate SP1; Windows 2008 Server;
English/German
Single License for one installation 6GK1713-5CB71-3AA0
Software Update Service 6GK1713-5CB00-3AL0
For 1 year with automatic extension;
requirement: current software ver-
sion
Upgrade
• From Edition 2006 or 2007
to S7-5613 Edition 2008 or
HARDNET-PB S7 V8.1
6GK1713-5CB00-3AE0
• From V6.0, V6.1, V6.2 or V6.3
to S7-5613 Edition 2008 or
HARDNET-PB S7 V8.1
6GK1713-5CB00-3AE1
FMS-5613 Edition 2008
Software for FMS protocol incl.
PG/OP communication; FDL,
FMS-OPC server and NCM PC;
runtime software, software and elec-
tronic manual on USB stick, Class A,
for 32-bit Windows XP Professional
SP2/3; Windows 2003 Server R2,
SP2; Windows Vista Business/
Ultimate SP1; Windows 2008 Server;
for CP 5603, CP 5613, CP 5613 A2,
CP 5623, CP 5613 FO, CP 5614,
CP 5614 A2, CP 5624;
German/English
• Single License for one installation 6GK1713-5FB71-3AA0
Software Update Service 6GK1713-5FB00-3AL0
For 1 year with automatic extension;
requirement: current software ver-
sion
Upgrade
• From Edition 2006 or 2007
to FMS-5613 Edition 2008 6GK1713-5FB00-3AE0
• From V6.0, V6.1, V6.2 or V6.3
to FMS-5613 Edition 2008 6GK1713-5FB00-3AE1
PROFIBUS FC Standard Cable GP 6XV1830-0EH10
Standard type with special design
for quick assembly, 2-core,
shielded,
sold in meters;
delivery unit max. 1000 m,
minimum order 20 m
PROFIBUS FastConnect
bus connector
RS485 Plug 180
6GK1500-0FC10
With 180° cable outlet,
insulation displacement
PROFIBUS bus terminal 12M 6GK1500-0AA10
Bus terminal for connection of
PROFIBUS stations up to 12 Mbit/s
with plug-in cable 1.5 m long
PROFIBUS FastConnect
Stripping Tool 6GK1905-6AA00
Preset stripping tool for fast
stripping of PROFIBUS FastConnect
bus cables
ST80_2013_EN_Kap05.book Seite 210 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — PROFIBUS
CP 5613 A2
5/211
Siemens ST 80 / ST PC · 2013
Overview
PCI card (universal keyed 5 V/3.3 V) with own microprocessor
for connection of PCs and SIMATIC PG/PC to PROFIBUS at up
to 12 Mbit/s
Communication services:
- PROFIBUS DP master according to IEC 61158/61784 on a
PCI card
- PG/OP communication with STEP 5 and STEP 7
- S7 communication with HARDNET-PB S7 software package
- Open communication (SEND/RECEIVE) based on the
FDL interface
- PROFIBUS FMS according to IEC 61158/61784 with
FMS-5613 software package
Comprehensive diagnostics possibilities for installation,
commissioning and operation of the module
High performance over direct dual-port RAM access
Event and filter mechanisms to reduce the loading on the host
CPU
Multiprotocol operation and parallel operation of up to four
CPs
Implementation in Motion Control applications is possible
because a constant bus cycle time is supported
The appropriate OPC servers and configuration tools are
included in the scope of supply of the respective communica-
tions software.
Ordering data
Order No.
*B,.B;;B
663*2323&)06'36'30
CP 5613 A2
communications processor 6GK1561-3AA01
PCI card (32-bit; 3.3 V/5 V) for
connection to PROFIBUS incl.
DP-Base software with NCM PC;
DP-RAM interface for DP master,
incl. PG and FDL protocols; single
license for one installation, runtime
software, software and electronic
manual on CD-ROM, Class A,
for operating system support
see SIMATIC NET software;
German/English
Software Upgrade 6GK1561-3AA01-3AE0
For CP 5603, CP 5613 A2 and
CP 5623 to Edition 2008 or V8.1
HARDNET-PB DP
Development Kit See http://www.siemens.com/
simatic-net/dk5613
HARDNET-PB DP Development Kit
software for CP 5613/CP 5614/
CP 5613 A2/CP 5614 A2/
CP 5613 FO for integration into
other operating system environ-
ments on systems with a PCI slot
HARDNET-PB DP
Software for DP, incl. PG and FDL
protocol, OPC server and NCM PC;
runtime software, software and elec-
tronic manual on CD-ROM, license
key on USB flash drive, Class A, for
CP 5603, CP 5613 A2, CP 5623,
CP 5614 A2, CP 5624;
HARDNET-PB DP V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single License for one installation 6GK1713-5DB08-2AA0
DP-5613 Edition 2008
For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/Ultimate
SP1; Windows 2008 Server;
English/German
• Single License for one installation 6GK1713-5DB71-3AA0
Software Update Service 6GK1713-5DB00-3AL0
For 1 year with automatic extension;
requirement: current software ver-
sion
Upgrade
• From Edition 2006 or 2007 to
DP-5613 Edition 2008 or
HARDNET-PB DP V8.1
6GK1713-5DB00-3AE0
• From V6.0, V6.1, V6.2 or V6.3 to
DP-5613 Edition 2008 or
HARDNET-PB DP V8.1
6GK1713-5DB00-3AE1
ST80_2013_EN_Kap05.book Seite 211 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — PROFIBUS
CP 5613 A2
5/212 Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
5
More information
You can find the HARDNET-PB DP Development Kit on the
Internet.
You will find more information on the Internet at:
http://www.siemens.com/simatic-net/dk5613
The CP 5613 A2 module can also be used under the LINUX and
UNIX operating systems. Information on the available LINUX
distributors and UNIX operating systems can be found at:
www.siemens.com/simatic-net/ik-info
HARDNET-PB S7
Software for S7 communication, incl.
PG and FDL protocol, OPC server
and NCM PC; runtime software,
software and electronic manual
on USB flash drive, Class A, for
CP 5603, CP 5613 A2, CP 5623,
CP 5614 A2, CP 5624;
HARDNET-PB S7 V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
Single License for one installation 6GK1713-5CB08-2AA0
S7-5613 Edition 2008
For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/Ultimate
SP1; Windows 2008 Server;
English/German
Single License for one installation 6GK1713-5CB71-3AA0
Software Update Service 6GK1713-5CB00-3AL0
For 1 year with automatic extension;
requirement: current software
version
Upgrade
From Edition 2006 or 2007 to
S7-5613 Edition 2008 or
HARDNET-PB S7 V8.1
6GK1713-5CB00-3AE0
• From V6.0, V6.1, V6.2 or V6.3 to
S7-5613 Edition 2008 or
HARDNET-PB S7 V8.1
6GK1713-5CB00-3AE1
FMS-5613 Edition 2008
Software for FMS protocol, including
PG/OP communication, FDL,
FMS-OPC server and NCM PC;
runtime software, software and elec-
tronic manual on USB flash drive,
Class A for 32-bit Windows XP
Professional SP2/3, Windows 2003
Server R2, SP2, Windows Vista
Business/Ultimate SP1;
Windows 2008 Server; for CP 5613,
CP 5613 A2, CP 5613 FO, CP 5614,
CP 5614 A2; German/English
Single License for one installation 6GK1713-5FB71-3AA0
Software Update Service 6GK1713-5FB00-3AL0
For 1 year with automatic extension;
requirement: current software
version
Upgrade
• From Edition 2006 or 2007
to FMS-5613 Edition 2008 6GK1713-5FB00-3AE0
• From V6.0, V6.1, V6.2 or V6.3
to FMS-5613 Edition 2008 6GK1713-5FB00-3AE1
PROFIBUS FC Standard Cable GP 6XV1830-0EH10
Standard type with special design
for quick assembly, 2-core,
shielded,
sold in meters;
delivery unit max. 1000 m,
minimum order 20 m
PROFIBUS FastConnect
bus connector
RS485 Plug 180
6GK1500-0FC10
With 180° cable outlet, insulation
displacement
PROFIBUS bus terminal 12M 6GK1500-0AA10
Bus terminal for connection of
PROFIBUS stations up to 12 Mbit/s
with plug-in cable 1.5 m long
PROFIBUS FastConnect
Stripping Tool 6GK1905-6AA00
Preset stripping tool for fast
stripping of PROFIBUS FastConnect
bus cables
ST80_2013_EN_Kap05.book Seite 212 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — PROFIBUS
CP 5614 A2
5/213
Siemens ST 80 / ST PC · 2013
Overview
PCI card (universal keyed 5 V/3.3 V) with own microprocessor
for connection of PCs and SIMATIC PG/PC to PROFIBUS at up
to 12 Mbit/s
Communication services:
- PROFIBUS DP master and slave interface according to
IEC 61158/61784 on one PCI card
- PG/OP communication with STEP 5 and STEP 7
- S7 communication with HARDNET-PB S7 software package
- Open communication (SEND/RECEIVE) based on the
FDL interface
- PROFIBUS FMS according to IEC 61158/61784 with
FMS-5613 software package
Comprehensive diagnostics possibilities for installation,
commissioning and operation of the module
High performance over direct dual-port RAM access
Event and filter mechanisms to reduce the loading on the host
CPU
Multiprotocol operation and parallel operation of up to four
CPs
Implementation of Motion Control applications is possible
because a constant bus cycle time is supported
The appropriate OPC servers and configuration tools are
included in the scope of supply of the respective communica-
tions software.
Ordering data
Order No.
*B,.B;;B
663*2323&)06'36'30
CP 5614 A2
communications processor 6GK1561-4AA01
PCI card (32-bit; 3.3 V/5 V) master and
slave connection to PROFIBUS
incl. DP-Base software with NCM PC;
DP-RAM interface for DP master, incl.
PG and FDL protocols; single license
for one installation, runtime software,
software and electronic manual on
CD-ROM, Class A, for operating
system support see SIMATIC NET
software;
German/English
Software Upgrade 6GK1561-3AA01-3AE0
For CP 5614 A2 and CP 5624 to
Edition 2008 or V8.1
HARDNET-PB DP Development Kit See http://www.siemens.com/
simatic-net/dk5613
HARDNET-PB DP Development Kit
software for CP 5613/CP 5614/
CP 5613 A2/CP 5614 A2/ CP 5613 FO
for integration into other operating
system environments on systems with
a PCI slot
HARDNET-PB DP
Software for DP, incl. PG and
FDL protocol, OPC server and
NCM PC; runtime software, software
and electronic manual on CD-ROM,
license key on USB flash drive,
Class A, for CP 5603, CP 5613 A2,
CP 5623, CP 5614, CP 5614 A2,
CP 5624;
HARDNET-PB DP V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single License for one installation 6GK1713-5DB08-2AA0
DP-5613 Edition 2008
For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/Ultimate SP1;
Windows 2008 Server;
English/German
• Single License for one installation 6GK1713-5DB71-3AA0
Software Update Service 6GK1713-5DB00-3AL0
For 1 year with automatic extension;
requirement: current software version
Upgrade
• From Edition 2006 or 2007 to
DP-5613 Edition 2008 or
HARDNET-PB DP V8.1
6GK1713-5DB00-3AE0
• From V6.0, V6.1, V6.2 or V6.3 to
DP-5613 Edition 2008 or
HARDNET-PB DP V8.1
6GK1713-5DB00-3AE1
ST80_2013_EN_Kap05.book Seite 213 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — PROFIBUS
CP 5614 A2
5/214 Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
5
More information
You can find the HARDNET-PB DP Development Kit on the
Internet.
http://www.siemens.com/simatic-net/dk5613
HARDNET-PB S7
Software for S7 communication, incl.
PG and FDL protocol, OPC server and
NCM PC; runtime software, software
and electronic manual on USB flash
drive, Class A, for CP 5603,
CP 5613 A2, CP 5623, CP 5614 A2,
CP 5624;
HARDNET-PB S7 V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
Single License for one installation 6GK1713-5CB08-2AA0
S7-5613 Edition 2008
For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/Ultimate SP1;
Windows 2008 Server;
English/German
Single License for one installation 6GK1713-5CB71-3AA0
Software Update Service
For 1 year with automatic extension;
requirement: current software version 6GK1713-5CB00-3AL0
Upgrade
From Edition 2006 or 2007 to
S7-5613 Edition 2008 or
HARDNET-PB S7 V8.1
6GK1713-5CB00-3AE0
• From V6.0, V6.1, V6.2 or V6.3 to
S7-5613 Edition 2008 or
HARDNET-PB S7 V8.1
6GK1713-5CB00-3AE1
FMS-5613 Edition 2008
Software for FMS protocol,
including PG/OP communication, FDL,
FMS-OPC server and NCM PC; run-
time software, software and electronic
manual on USB flash drive, Class A
for 32-bit Windows XP Professional
SP2/3, Windows 2003 Server R2, SP2,
Windows Vista Business/Ultimate SP1;
Windows 2008 Server; for CP 5613,
CP 5613 A2, CP 5613 FO, CP 5614,
CP 5614 A2,
German/English
Single License for one installation 6GK1713-5FB71-3AA0
Software Update Service 6GK1713-5FB00-3AL0
For 1 year with automatic extension;
requirement: current software version
Upgrade
• From Edition 2006 or 2007 to
FMS-5613 Edition 2008 6GK1713-5FB00-3AE0
• From V6.0, V6.1, V6.2 or V6.3 to
FMS-5613 Edition 2008 6GK1713-5FB00-3AE1
PROFIBUS FC Standard Cable GP 6XV1830-0EH10
Standard type with special design
for quick assembly, 2-core, shielded,
sold in meters;
delivery unit max. 1000 m,
minimum order 20 m
PROFIBUS FastConnect
bus connector
RS485 Plug 180
6GK1500-0FC10
With 180° cable outlet,
insulation displacement
PROFIBUS bus terminal 12M 6GK1500-0AA10
Bus terminal for connection of
PROFIBUS stations up to 12 Mbit/s
with plug-in cable 1.5 m long
PROFIBUS FastConnect
Stripping Tool 6GK1905-6AA00
Preset stripping tool for fast stripping
of PROFIBUS FastConnect bus cables
ST80_2013_EN_Kap05.book Seite 214 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — PROFIBUS
CP 5623
5/215
Siemens ST 80 / ST PC · 2013
Overview
PCI Express card (PCIe x1) with own microprocessor for
connecting PCs and SIMATIC PG/PC to PROFIBUS at up to
12 Mbit/s
Communication services:
- PROFIBUS DP master Class 1 and 2 or DP slave according
to IEC 61158/61784 on a PCI card
- PG/OP communication with STEP 5 and STEP 7
- S7 communication with HARDNET-PB S7 software package
- Open communication (SEND/RECEIVE) based on the
FDL interface
- PROFIBUS FMS according to IEC 61158/61784 with
FMS-5613 software package
Extensive diagnostics options for installation, commissioning
and operation of the module
Event and filter mechanism for reducing the load on the host
CPU
Multiprotocol operation and parallel operation of up to four
CPs
The appropriate OPC servers and configuration tools are
included in the scope of supply of the respective communi-
cation software
Ordering data
Order No.
*B,.B;;B
663*2323&)06'36'30
CP 5623
communications processor 6GK1562-3AA00
PCI Express x1 card (32 bit) for
connection to PROFIBUS incl.
DP-Base software with NCM PC;
DP-RAM interface for DP master or
DP slave, incl. PG and FDL proto-
cols; single license for one installa-
tion, runtime software, software and
electronic manual on CD-ROM,
Class A, for operating system sup-
port see SIMATIC NET software;
German/English
Software Upgrade 6GK1561-3AA01-3AE0
For CP 5603, CP 5613 A2 and
CP 5623 to Edition 2008 or V8.1
HARDNET-PB DP
Development Kit see http://www.siemens.com/
simatic-net/dk5613
HARDNET-PB DP Development Kit
software for
CP 5603, CP 5613, CP 5613 A2,
CP 5623, CP 5613 FO, CP 5614,
CP 5614 A2, CP 5624;
for integration into other operating
system environments on systems
with a PCI or PCI Express slot
HARDNET-PB DP
Software for DP, incl. PG and
FDL protocol, OPC server and
NCM PC; runtime software, software
and electronic manual on CD-ROM,
license key on USB flash drive,
Class A, for CP 5603, CP 5613 A2,
CP 5623, CP 5614 A2, CP 5624;
HARDNET-PB DP V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single License for one installation 6GK1713-5DB08-2AA0
DP-5613, Edition 2008
For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
indows Vista Business/
Ultimate SP1; Windows 2008 Server;
English/German
• Single License for one installation 6GK1713-5DB71-3AA0
Software Update Service 6GK1713-5DB00-3AL0
For 1 year with automatic extension;
requirement: current software
version
Upgrade
• From Edition 2006 or 2007 to
DP-5613 Edition 2008 or
HARDNET-PB DP V8.1
6GK1713-5DB00-3AE0
• From V6.0, V6.1, V6.2 or V6.3 to
DP-5613 Edition 2008 or
HARDNET-PB DP V8.1
6GK1713-5DB00-3AE1
ST80_2013_EN_Kap05.book Seite 215 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — PROFIBUS
CP 5623
5/216 Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
5
More information
You can find the HARDNET-PB DP Development Kit on the
Internet.
You will find more information on the Internet at:
http://www.siemens.com/simatic-net/dk5613
The CP 5623 module can also be used under LINUX and UNIX
operating systems. Information on the available LINUX distrib-
utors and UNIX operating systems can be found at:
www.siemens.com/simatic-net/ik-info
HARDNET-PB S7
Software for S7 communication, incl.
PG and FDL protocol, OPC server
and NCM PC; runtime software,
software and electronic manual
on USB flash drive, Class A, for
CP 5603, CP 5613 A2, CP 5623,
CP 5614 A2, CP 5624;
HARDNET-PB S7 V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
Single License for one installation 6GK1713-5CB08-2AA0
S7-5613 Edition 2008
For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/
Ultimate SP1; Windows 2008 Server;
English/German
Single License for one installation 6GK1713-5CB71-3AA0
Software Update Service 6GK1713-5CB00-3AL0
For 1 year with automatic extension;
requirement: current software
version
Upgrade
From Edition 2006 or 2007 to
S7-5613 Edition 2008 or
HARDNET-PB S7 V8.1
6GK1713-5CB00-3AE0
• From V6.0, V6.1, V6.2 or V6.3 to
S7-5613 Edition 2008 or
HARDNET-PB S7 V8.1
6GK1713-5CB00-3AE1
FMS-5613 Edition 2008
Software for FMS protocol incl.
PG/OP communication; FDL,
FMS-OPC server and NCM PC;
runtime software, software and elec-
tronic manual on USB stick, Class A,
for 32-bit Windows XP Professional
SP2/3; Windows 2003 Server R2,
SP2; Windows Vista Business/
Ultimate SP1; Windows 2008 Server;
for CP 5603, CP 5613, CP 5613 A2,
CP 5623, CP 5613 FO, CP 5614,
CP 5614 A2, CP 5624;
German/English
Single License for one installation 6GK1713-5FB71-3AA0
Software Update Service 6GK1713-5FB00-3AL0
For 1 year with automatic extension;
requirement: current software
version
Upgrade
• From Edition 2006 or 2007 to
FMS-5613 Edition 2008 6GK1713-5FB00-3AE0
• From V6.0, V6.1, V6.2 or V6.3 to
FMS-5613 Edition 2008 6GK1713-5FB00-3AE1
PROFIBUS FC Standard Cable GP 6XV1830-0EH10
Standard type with special design
for quick assembly, 2-core,
shielded,
sold in meters;
delivery unit max. 1000 m,
minimum order 20 m
PROFIBUS FastConnect
bus connector
RS485 Plug 180
6GK1500-0FC10
With 180° cable outlet, insulation
displacement
PROFIBUS bus terminal 12M 6GK1500-0AA10
Bus terminal for connection of
PROFIBUS stations up to 12 Mbit/s
with plug-in cable 1.5 m long
PROFIBUS FastConnect
Stripping Tool 6GK1905-6AA00
Preset stripping tool for fast
stripping of PROFIBUS FastConnect
bus cables
ST80_2013_EN_Kap05.book Seite 216 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — PROFIBUS
CP 5624
5/217
Siemens ST 80 / ST PC · 2013
Overview
PCI Express card (PCIe x1) with own microprocessor for
connecting PCs and SIMATIC PG/PC to PROFIBUS at up to
12 Mbit/s
Two 9-pin sub-D sockets for parallel operation as DP master
and DP slave
Communication services:
- PROFIBUS DP master and slave interface according to
IEC 61158/61784 on one PCI card
- PG/OP communication with STEP 5 and STEP 7
- S7 communication with HARDNET-PB S7 software package
- Open communication (SEND/RECEIVE) based on the
FDL interface
- PROFIBUS FMS according to IEC 61158/61784 with
FMS-5613 software package
Extensive diagnostics options for installation, commissioning
and operation of the module
Event and filter mechanism for reducing the load on the host
CPU
Multiprotocol operation and parallel operation of up to four
CPs
The appropriate OPC servers and configuration tools are
included in the scope of supply of the respective communi-
cation software
Ordering data
Order No.
*B,.B;;B
663*2323&)06'36'30
CP 5624 A2
communications processor 6GK1562-4AA00
PCI Express x1 card (32 bit) for master
and slave connection to PROFIBUS
incl. DP-Base software with NCM PC;
DP-RAM interface for DP master, incl.
PG and FDL protocols; single license
for one installation, runtime software,
software and electronic manual on
CD-ROM, Class A, for operating
system support see SIMATIC NET
software;
German/English
Software Upgrade 6GK1561-3AA01-3AE0
for CP 5614 A2 and CP 5624 to
Edition 2008 or V8.1
HARDNET-PB DP Development Kit see http://www.siemens.com/
simatic-net/dk5613
HARDNET-PB DP Development Kit
software for
CP 5603, CP 5613, CP 5613 A2,
CP 5623, CP 5613 FO, CP 5614,
CP 5614 A2, CP 5624;
for integration into other operating
system environments on systems
with a PCI or PCI Express slot
HARDNET-PB DP
Software for DP, incl. PG and
FDL protocol, OPC server and
NCM PC; runtime software, software
and electronic manual on CD-ROM,
license key on USB flash drive,
Class A, for CP 5603, CP 5613 A2,
CP 5623, CP 5614 A2, CP 5624;
HARDNET-PB DP V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single License for one installation 6GK1713-5DB08-2AA0
DP-5613, Edition 2008
For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/Ultimate SP1;
Windows 2008 Server;
English/German
• Single License for one installation 6GK1713-5DB71-3AA0
Software Update Service 6GK1713-5DB00-3AL0
For 1 year with automatic extension;
requirement: current software version
Upgrade
• From Edition 2006 or 2007 to
DP-5613 Edition 2008 or
HARDNET-PB DP V8.1
6GK1713-5DB00-3AE0
• From V6.0, V6.1, V6.2 or V6.3 to
DP-5613 Edition 2008 or
HARDNET DP V8.1
6GK1713-5DB00-3AE1
ST80_2013_EN_Kap05.book Seite 217 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — PROFIBUS
CP 5624
5/218 Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
5
More information
You can find the HARDNET-PB DP Development Kit on the
Internet.
You can find more information on the Internet at:
http://www.siemens.com/simatic-net/dk5613
HARDNET-PB S7
Software for S7 communication, incl.
PG and FDL protocol, OPC server and
NCM PC; runtime software, software
and electronic manual on USB flash
drive, Class A, for CP 5603,
CP 5613 A2, CP 5623, CP 5614 A2,
CP 5624;
HARDNET-PB S7 V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
Single License for one installation 6GK1713-5CB08-2AA0
S7-5613 Edition 2008
For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/Ultimate SP1;
Windows 2008 Server;
English/German
Single License for one installation 6GK1713-5CB71-3AA0
Software Update Service 6GK1713-5CB00-3AL0
For 1 year with automatic extension;
requirement: current software version
Upgrade
From Edition 2006 or 2007 to
S7-5613 Edition 2008 or
HARDNET-PB S7 V8.1
6GK1713-5CB00-3AE0
• From V6.0, V6.1, V6.2 or V6.3 to
S7-5613 Edition 2008 or
HARDNET-PB S7 V8.1
6GK1713-5CB00-3AE1
FMS-5613 Edition 2008
Software for FMS protocol incl.
PG/OP communication; FDL,
FMS-OPC server and NCM PC;
runtime software, software and
electronic manual on USB flash drive,
Class A, for 32-bit Windows XP
Professional SP2/3; Windows 2003
Server R2, SP2; Windows Vista
Business/Ultimate SP1; Windows 2008
Server; for CP 5603, CP 5613,
CP 5613 A2, CP 5623, CP 5613 FO,
CP 5614, CP 5614 A2, CP 5624;
German/English
• Single License for one installation 6GK1713-5FB71-3AA0
Software Update Service 6GK1713-5FB00-3AL0
For 1 year with automatic extension;
requirement: current software version
Upgrade
• From Edition 2006 or 2007 to
FMS-5613 Edition 2008 6GK1713-5FB00-3AE0
• From V6.0, V6.1, V6.2 or V6.3 to
FMS-5613 Edition 2008 6GK1713-5FB00-3AE1
PROFIBUS FastConnect
bus connector RS 485 Plug 180 6GK1500-0FC10
with 180° cable outlet
PROFIBUS bus terminal 12M 6GK1500-0AA10
Bus terminal for connection of
PROFIBUS stations for up to 12 Mbit/s
with plug-in cable
ST80_2013_EN_Kap05.book Seite 218 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — PROFIBUS
CP 5512
5/219
Siemens ST 80 / ST PC · 2013
Overview
PC Card Type II (CardBus 32 bit) to connect PG/PC and
notebooks with PC card slot (CardBus 32 bit) to PROFIBUS
and to the MPI of the SIMATIC S7
Communication services:
- PROFIBUS DP Master Class 1 incl. acyclic DP expansions
with SOFTNET-PB DP software package
- PROFIBUS DP Master Class 2 incl. acyclic DP expansions
with SOFTNET-PB DP software package
- PROFIBUS DP slave with SOFTNET-PB DP Slave software
package
- PG/OP communication with STEP 5 or STEP 7
- S7 communication with SOFTNET-PB S7 software package
- Open communication (SEND/RECEIVE on basis of the FDL
interface) with SOFTNET-PB DP or SOFTNET-PB S7 software
package
Can be used with:
- STEP 7 and NCM PC; (ProTool, Micro/Win, ProTool/Pro,
SIMATIC PDM for PG/OP communication)
- SOFTNET-PB S7 (for S7 communication)
- SOFTNET-PB DP, SOFTNET-PB DP slave (for DP)
The appropriate OPC servers are included in the scope of
supply of the respective communication software
Ordering data
Order No.
*B,.B;;B
663*2323&)06'36'30
CP 5512
communications processor 6GK1551-2AA00
PC-Card (CardBus, 32-bit) for
connection of a programming
device or notebook to PROFIBUS or
MPI, under 32 bit in connection with
PROFIBUS SOFTNET software or
STEP 7;
German/English
SOFTNET-PB S7
Software for S7 communication, incl.
FDL protocol with OPC server and
NCM PC, runtime software, software
and electronic manual on CD-ROM,
license key on USB flash drive,
Class A; for CP 5512, CP 5611,
CP 5611 A2, CP 5612 (Win 7 and
higher), CP 5621, CP 5622
(Win 7 and higher), CP 5711;
SOFTNET-PB S7 V8.2
for 32 Bit Windows 7 Professional/
Ultimate; English/German
• Single License for one installation 6GK1704-5CW08-2AA0
SOFTNET-S7 Edition 2008
for 32 Bit Windows XP Professional
SP2/3; Windows 2003 Server R2,
SP2; Windows Vista Business/
Ultimate SP1; Windows 2008 Server;
English/German
• Single License for one installation 6GK1704-5CW71-3AA0
Software Update Service 6GK1704-5CW00-3AL0
For 1 year with automatic extension;
requirement: current software
version
Upgrade
• From Edition 2006 to
SOFTNET-S7 Edition 2008 or V8.1 6GK1704-5CW00-3AE0
• From V6.0, V6.1, V6.2 or V6.3 to
SOFTNET-S7 Edition 2008 or V8.1 6GK1704-5CW00-3AE1
ST80_2013_EN_Kap05.book Seite 219 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — PROFIBUS
CP 5512
5/220 Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
5
SOFTNET-PB DP
Software for DP protocol
(master class 1 and 2),
incl. FDL protocol with OPC server
and NCM PC,
runtime software, software and elec-
tronic manual on CD-ROM, license
key on USB flash drive; for CP 5512,
CP 5611, CP 5611 A2, CP 5612
(Win 7 and higher), CP 5621,
CP 5622 (Win 7 and higher),
CP 5711;
SOFTNET-PB DP V8.2
for 32 Bit Windows 7 Professional/
Ultimate; English/German
Single License for one installation 6GK1704-5DW08-2AA0
SOFTNET-DP Edition 2008 (V7.1)
for Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/Ultimate
SP1; Windows 2008 Server;
English/German
Single License for one installation 6GK1704-5DW71-3AA0
Software Update Service 6GK1704-5DW00-3AL0
For 1 year with automatic extension;
requirement: current software
version
Upgrade
From Edition 2006 to
SOFTNET-DP Edition 2008 or V8.1 6GK1704-5DW00-3AE0
• From V6.0, V6.1, V6.2 or V6.3 to
SOFTNET-DP Edition 2008 or V8.1 6GK1704-5DW00-3AE1
SOFTNET-PB DP slave
Software for DP slave, with DP OPC
server and NCM PC, single license
for one installation, runtime software,
software and electronic manual on
CD-ROM, license key on USB flash
drive, Class A; for CP 5512,
CP 5611, CP 5611 A2, CP 5612
(Win 7 and higher), CP 5621,
CP 5622 (Win 7 and higher),
CP 5711;
SOFTNET-PB DP Slave V8.2
for 32/64-bit: Windows 7
Professional/Ultimate;
for 64-bit: Windows 2008 Server R2
German/English
• Single License for one installation 6GK1704-5SW08-2AA0
SOFTNET-DP Slave Edition 2008
(V7.1)
for 32 Bit Windows XP Professional
SP2/3; Windows 2003 Server R2,
SP2; Windows Vista Business/
Ultimate SP1; Windows 2008 Server;
English/German
• Single License for one installation 6GK1704-5SW71-3AA0
Software Update Service 6GK1704-5SW00-3AL0
For 1 year with automatic extension;
requirement: current software ver-
sion
Upgrade
• From Edition 2006 to
SOFTNET-DP Slave Edition 2008
or V8.1
6GK1704-5SW00-3AE0
• From V6.0, V6.1, V6.2 or V6.3 to
SOFTNET-DP Slave Edition 2008
or V8.1
6GK1704-5SW00-3AE1
PROFIBUS FastConnect
bus connector
RS 485 Plug 180
6GK1500-0FC10
With 180° cable outlet
PROFIBUS adapter for CP 5512 C79459-A1890-A10
ST80_2013_EN_Kap05.book Seite 220 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — PROFIBUS
CP 5612
5/221
Siemens ST 80 / ST PC · 2013
Overview
PCI card (universal-keyed 5 V/3.3 V) for connecting PCs and
SIMATIC PG/PC to PROFIBUS at up to 12 Mbit/s and to the
MPI interface of SIMATIC S7
Communication services:
- PROFIBUS DP Master Class 1 incl. acyclic DP expansions
with SOFTNET-PB DP software package
- PROFIBUS DP Master Class 2 incl. acyclic DP expansions
with SOFTNET-PB DP software package
- PROFIBUS DP slave with SOFTNET-PB DP Slave software
package
- PG/OP communication with STEP 7
- S7 communication with SOFTNET-PB S7 software package
- Open communication (SEND/RECEIVE on basis of the FDL
interface) with SOFTNET-PB DP or SOFTNET-PB S7 software
package
Can be used with:
- STEP 7, STEP 7-Micro/Win, SIMATIC PDM
(for PG/OP communication)
- SOFTNET-PB S7 (for S7 communication)
- SOFTNET-PB DP, SOFTNET-PB DP slave (for DP)
The appropriate OPC servers and configuration tools are
included in the scope of supply of the respective communica-
tions software.
Ordering data
Order No.
*B,.B;;B
663*2323&)06'36'30
CP 5612
communications processor
• PCI card (32-bit)
for connection of a programming
device or PC to PROFIBUS
6GK1561-2AA00
• PCI card (32-bit)
CP 5612 and MPI cable, 5 m 6GK1561-2AM00
SOFTNET-PB S7
Software for S7 communication, incl.
FDL protocol with OPC server and
NCM PC, runtime software, software
and electronic manual on CD-ROM,
license key on USB flash drive,
Class A; for CP 5512, CP 5611,
CP 5611 A2, CP 5612
(Win 7 and higher), CP 5621,
CP 5622 (Win 7 and higher),
CP 5711;
SOFTNET-PB S7 V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single License for one installation 6GK1704-5CW08-2AA0
Software Update Service 6GK1704-5CW00-3AL0
For 1 year with automatic extension;
requirement: current software
version
Upgrade
• From Edition 2006 to
SOFTNET-S7 Edition 2008 or V8.1 6GK1704-5CW00-3AE0
• From V6.0, V6.1, V6.2 or V6.3 to
SOFTNET-S7 Edition 2008 or V8.1 6GK1704-5CW00-3AE1
SOFTNET-PB DP
Software for DP protocol
(master class 1 and 2), incl.
FDL protocol with OPC server and
NCM PC, runtime software, software
and electronic manual on CD-ROM,
license key on USB flash drive; for
CP 5611 A2, CP 5612
(Win 7 and higher), CP 5621,
CP 5622 (Win 7 and higher),
CP 5711;
SOFTNET-PB DP V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single License for one installation 6GK1704-5DW08-2AA0
Software Update Service 6GK1704-5DW00-3AL0
For 1 year with automatic extension;
requirement: current software
version
Upgrade
• From Edition 2006 to
SOFTNET-DP Edition 2008 or V8.1 6GK1704-5DW00-3AE0
• From V6.0, V6.1, V6.2 or V6.3 to
SOFTNET-DP Edition 2008 or V8.1 6GK1704-5DW00-3AE1
ST80_2013_EN_Kap05.book Seite 221 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — PROFIBUS
CP 5612
5/222 Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
5
SOFTNET-PB DP slave
Software for DP slave, with DP OPC
server and NCM PC, single license
for one installation, runtime software,
software and electronic manual on
CD-ROM, license key on USB flash
drive, Class A; for CP 5611 A2,
CP 5612 (Win 7 and higher),
CP 5621, CP 5622
(Win 7 and higher), CP 5711;
SOFTNET-PB DP Slave V8.2
for 32/64-bit: Windows 7
Professional/Ultimate;
for 64-bit: Windows 2008 Server R2
German/English
Single License for one installation 6GK1704-5SW08-2AA0
Software Update Service 6GK1704-5SW00-3AL0
For 1 year with automatic extension;
requirement: current software
version
Upgrade
From Edition 2006 to SOFTNET-DP
Slave Edition 2008 or V8.1 6GK1704-5SW00-3AE0
• From V6.0, V6.1, V6.2 or V6.3 to
SOFTNET-DP Slave Edition 2008
or V8.1
6GK1704-5SW00-3AE1
PROFIBUS FastConnect
bus connector
RS 485 Plug 180
6GK1500-0FC10
With 180° cable outlet
PROFIBUS bus terminal 12M 6GK1500-0AA10
Bus terminal for connection of
PROFIBUS stations for up to
12 Mbit/s with plug-in cable
ST80_2013_EN_Kap05.book Seite 222 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — PROFIBUS
CP 5622
5/223
Siemens ST 80 / ST PC · 2013
Overview
PCI Express card (PCIe x1) for connection of PCs and
SIMATIC PG/PC to PROFIBUS at up to 12 Mbit/s and to the
MPI of the SIMATIC S7
Communication services:
- PROFIBUS DP Master Class 1 incl. acyclic DP expansions
with SOFTNET-PB DP software package
- PROFIBUS DP Master Class 2 incl. acyclic DP expansions
with SOFTNET-PB DP software package
- PROFIBUS DP slave with SOFTNET-PB DP Slave software
package
- PG/OP communication with STEP 7
- S7 communication with SOFTNET-PB S7 software package
- Open communication (SEND/RECEIVE on basis of the FDL
interface) with SOFTNET-PB DP or SOFTNET-PB S7 software
package
Can be used with:
- STEP 7, STEP 7-Micro/Win, SIMATIC PDM
(for PG/OP communication)
- SOFTNET-PB S7 (for S7 communication)
- SOFTNET-PB DP, SOFTNET-PB DP slave (for DP)
The appropriate OPC servers and configuration tools are
included in the scope of supply of the respective communica-
tions software.
Ordering data
Order No.
*B,.B;;B
663*2323&)06'36'30
CP 5622
communications processor
• PCI Express x1 card (32-bit)
for connection of a PG or PC
to PROFIBUS
6GK1562-2AA00
• PCI Express x1 card (32-bit)
CP 5622 and MPI cable, 5 m 6GK1562-2AM00
SOFTNET-PB S7
Software for S7 communication, incl.
FDL protocol with OPC server and
NCM PC, runtime software, software
and electronic manual on CD-ROM,
license key on USB flash drive,
Class A; for CP 5512, CP 5611,
CP 5611 A2, CP 5612
(Win 7 and higher), CP 5621,
CP 5622 (Win 7 and higher),
CP 5711;
SOFTNET-PB S7 V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single License for one installation 6GK1704-5CW08-2AA0
Software Update Service 6GK1704-5CW00-3AL0
For 1 year with automatic extension;
requirement: current software
version
Upgrade
• From Edition 2006 to
SOFTNET-S7 Edition 2008 or V8.1 6GK1704-5CW00-3AE0
• From V6.0, V6.1, V6.2 or V6.3 to
SOFTNET-S7 Edition 2008 or V8.1 6GK1704-5CW00-3AE1
SOFTNET-PB DP
Software for DP protocol
(master class 1 and 2), incl.
FDL protocol with OPC server and
NCM PC, runtime software, software
and electronic manual on CD-ROM,
license key on USB flash drive; for
CP 5611 A2, CP 5612
(Win 7 and higher), CP 5621,
CP 5622 (Win 7 and higher),
CP 5711;
SOFTNET-PB DP V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single License for one installation 6GK1704-5DW08-2AA0
Software Update Service 6GK1704-5DW00-3AL0
For 1 year with automatic extension;
requirement: current software ver-
sion
Upgrade
• From Edition 2006 to
SOFTNET-DP Edition 2008 or V8.1 6GK1704-5DW00-3AE0
• From V6.0, V6.1, V6.2 or V6.3 to
SOFTNET-DP Edition 2008 or V8.1 6GK1704-5DW00-3AE1
ST80_2013_EN_Kap05.book Seite 223 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — PROFIBUS
CP 5622
5/224 Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
5
SOFTNET-PB DP slave
Software for DP slave, with DP OPC
server and NCM PC, single license
for one installation, runtime software,
software and electronic manual on
CD-ROM, license key on USB flash
drive, Class A; for CP 5611 A2,
CP 5612 (Win 7 and higher),
CP 5621, CP 5622
(Win 7 and higher), CP 5711;
SOFTNET-PB DP Slave V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit: Windows 2008 Server R2
German/English
Single License for one installation 6GK1704-5SW08-2AA0
Software Update Service 6GK1704-5SW00-3AL0
For 1 year with automatic extension;
requirement: current software
version
Upgrade
From Edition 2006 to SOFTNET-DP
Slave Edition 2008 or V8.1 6GK1704-5SW00-3AE0
• From V6.0, V6.1, V6.2 or V6.3 to
SOFTNET-DP Slave Edition 2008
or V8.1
6GK1704-5SW00-3AE1
PROFIBUS FastConnect
bus connector
RS 485 Plug 180
6GK1500-0FC10
With 180° cable outlet
PROFIBUS bus terminal 12M 6GK1500-0AA10
Bus terminal for connection of
PROFIBUS stations for up to
12 Mbit/s with plug-in cable
ST80_2013_EN_Kap05.book Seite 224 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — PROFIBUS
CP 5711
5/225
Siemens ST 80 / ST PC · 2013
Overview
USB adapter for the connection of PCs and SIMATIC PG/PC to
PROFIBUS DP or MPI via USB 2.0
Operation in extended temperature range of -20 °C to +60 °C
Active PROFIBUS termination to supply the PROFIBUS
network as end station of a segment
Robust USB connection due to mechanical locking of the USB
connector to the CP 5711 enclosure
Communication services:
- PROFIBUS DP master Class 1 and 2 according to
IEC 61158/61784 with SOFTNET-PB DP software package
- PROFIBUS DP slave with SOFTNET-PB DP Slave software
package
- PG/OP communication with STEP 5 or STEP 7 software
package
- S7 communication with SOFTNET-PB S7 software package
- Open communication (SEND/RECEIVE on basis of the FDL
interface) with SOFTNET-PB DP or SOFTNET-PB S7 software
package
PROFIBUS connection with up to 12 Mbit/s
Can be used with:
- STEP 7, STEP 7 Micro/WIN, WinCC/WinCC flexible,
NCM PC, SIMATIC PDM (for PG/OP communication)
- SOFTNET-PB S7 (for S7 communication)
- SOFTNET-PB DP, SOFTNET-PB DP slave (for DP)
The appropriate OPC servers and configuration tools are
included in the scope of supply of the respective communi-
cation software
Ordering data
Order No.
*B,.B;;B
663*2323&)06'36'30
CP 5711
communications processor
for connection of a programming
device or notebook to PROFIBUS or
MPI, under 32 bit in connection with
PROFIBUS SOFTNET software or
STEP 7;
German/English
• USB V2.0 adapter 6GK1571-1AA00
• USB V2.0 adapter CP 5711 and
MPI cable, 5 m 6GK1571-1AM00
Mounting rail support for CP 5711 6GK1571-1AA00-0AH0
Compartment for CP 5711
enclosure; fastened mechanically to
35 mm DIN rail
SOFTNET-PB S7
Software for S7 communication, incl.
FDL protocol with OPC server and
NCM PC, runtime software, software
and electronic manual on CD-ROM,
license key on USB flash drive,
Class A; for CP 5611 A2, CP 5612
(Win 7 and higher), CP 5621,
CP 5622 (Win 7 and higher),
CP 5711;
SOFTNET-PB S7 V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single License for one installation 6GK1704-5CW08-2AA0
SOFTNET-S7 Edition 2008 (V7.1)
For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/
Ultimate SP1; Windows 2008 Server;
English/German
• Single License for one installation 6GK1704-5CW71-3AA0
Software Update Service 6GK1704-5CW00-3AL0
For 1 year with automatic extension;
requirement: current software ver-
sion
Upgrade
• From Edition 2006 to
SOFTNET-S7 Edition 2008 or V8.1 6GK1704-5CW00-3AE0
• From V6.0, V6.1, V6.2 or V6.3 to
SOFTNET-S7 Edition 2008 or V8.1 6GK1704-5CW00-3AE1
ST80_2013_EN_Kap05.book Seite 225 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — PROFIBUS
CP 5711
5/226 Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
5
SOFTNET-PB DP
Software for DP protocol
(master class 1 and 2), incl.
FDL protocol with OPC server and
NCM PC, runtime software, software
and electronic manual on CD-ROM,
license key on USB flash drive;
for CP 5611 A2, CP 5612
(Win 7 and higher), CP 5621,
CP 5622 (Win 7 and higher),
CP 5711;
SOFTNET-PB DP V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
Single License for one installation 6GK1704-5DW08-2AA0
SOFTNET-DP Edition 2008 (V7.1)
For Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/Ultimate
SP1; Windows 2008 Server;
English/German
Single License for one installation 6GK1704-5DW71-3AA0
Software Update Service 6GK1704-5DW00-3AL0
For 1 year with automatic extension;
requirement: current software
version
Upgrade
From Edition 2006 to
SOFTNET-DP Edition 2008 or V8.1 6GK1704-5DW00-3AE0
• From V6.0, V6.1, V6.2 or V6.3 to
SOFTNET-DP Edition 2008 or V8.1 6GK1704-5DW00-3AE1
SOFTNET-PB DP slave
Software for DP slave, with DP OPC
server and NCM PC, single license
for one installation, runtime software,
software and electronic manual on
CD-ROM, license key on USB flash
drive, Class A; for CP 5611 A2,
CP 5612 (Win 7 and higher),
CP 5621, CP 5622
(Win 7 and higher), CP 5711;
SOFTNET-PB DP Slave V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single License for one installation 6GK1704-5SW08-2AA0
SOFTNET-DP Slave Edition 2008
(V7.1)
For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/
Ultimate SP1; Windows 2008 Server;
English/German
• Single License for one installation 6GK1704-5SW71-3AA0
Software Update Service 6GK1704-5SW00-3AL0
For 1 year with automatic extension;
requirement: current software
version
Upgrade
From Edition 2006 to SOFTNET-DP
Slave Edition 2008 or V8.1 6GK1704-5SW00-3AE0
• From V6.0, V6.1, V6.2 or V6.3 to
SOFTNET-DP Slave Edition 2008 or
V8.1
6GK1704-5SW00-3AE1
PROFIBUS FastConnect
bus connector
RS485 Plug 180
6GK1500-0FC10
With 180° cable outlet
ST80_2013_EN_Kap05.book Seite 226 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — PROFIBUS
SOFTNET for PROFIBUS
5/227
Siemens ST 80 / ST PC · 2013
Overview
Software for connecting PCs/programming devices and
notebooks to programmable controllers
Communication services:
- PROFIBUS DP master Class 1 and 2 with acyclic expansions
- PROFIBUS DP slave
- PG/OP communication
- S7 communication
- Open communication (SEND/RECEIVE) based on the FDL
interface
The corresponding OPC servers are included in the scope of
supply of the respective communication software
Can be used with:
- CP 5512 (PC card, CardBus 32-bit)
- CP 5611 A2 and CP 5612 (PCI, 32-bit)
- CP 5612 (PCI, 32-bit)
- CP 5621 and CP 5622 (PCIe x1)
- CP 5622 (PCIe x1)
- CP 5711 (USB V2.0)
- Integrated PROFIBUS interfaces of SIMATIC PGs/PCs
Ordering data
Order No.
PC/IPC with
CP 5612/
CP 5622/CP 5711
and SOFTNET for
PROFIBUS
S7-300 with CP 342-5
or CP 343-5
S7-400 with
CP 443-5
S5-115U to S5-155U
with CP 5431 FMS/DP
S7-1200 with
CM 1243-5
PROFIBUS
G_IK10_XX_50039
*B,.B;;B
663*2323&)06'36'30
SOFTNET-PB S7
Software for S7 communication, incl.
FDL protocol with OPC server and
NCM PC, runtime software, software
and electronic manual on CD-ROM,
license key on USB flash drive,
Class A; for CP 5611 A2, CP 5612
(Win 7 and higher), CP 5621,
CP 5622 (Win 7 and higher),
CP 5711;
SOFTNET-PB S7 V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single License for one installation 6GK1704-5CW08-2AA0
SOFTNET-S7 Edition 2008 (V7.1)
For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/
Ultimate SP1; Windows 2008 Server;
English/German
• Single License for one installation 6GK1704-5CW71-3AA0
Software Update Service 6GK1704-5CW00-3AL0
For 1 year with automatic extension;
requirement: current software version
Upgrade
• From Edition 2006 to
SOFTNET-S7 Edition 2008 or V8.1 6GK1704-5CW00-3AE0
• From V6.0, V6.1, V6.2 or V6.3 to
SOFTNET-S7 Edition 2008 or V8.1 6GK1704-5CW00-3AE1
ST80_2013_EN_Kap05.book Seite 227 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — PROFIBUS
SOFTNET for PROFIBUS
5/228 Siemens ST 80 / ST PC · 2013
Ordering data
Order No. Order No.
5
SOFTNET-PB DP
Software for DP protocol
(master class 1 and 2), incl.
FDL protocol with OPC server and
NCM PC, runtime software, software
and electronic manual on CD-ROM,
license key on USB flash drive; for
CP 5611 A2, CP 5612
(Win 7 and higher), CP 5621,
CP 5622 (Win 7 and higher),
CP 5711;
SOFTNET-PB DP V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
Single License for one installation 6GK1704-5DW08-2AA0
SOFTNET-DP Edition 2008 (V7.1)
For Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/Ultimate
SP1; Windows 2008 Server;
English/German
Single License for one installation 6GK1704-5DW71-3AA0
Software Update Service 6GK1704-5DW00-3AL0
For 1 year with automatic extension;
requirement: current software version
Upgrade
From Edition 2006 to
SOFTNET-DP Edition 2008 or V8.1 6GK1704-5DW00-3AE0
• From V6.0, V6.1, V6.2 or V6.3 to
SOFTNET-DP Edition 2008 or V8.1 6GK1704-5DW00-3AE1
SOFTNET-PB DP slave
Software for DP slave, with
DP OPC server and NCM PC,
single license for one installation,
runtime software, software and elec-
tronic manual on CD-ROM, license
key on USB flash drive, Class A; for
CP 5611 A2, CP 5612
(Win 7 and higher), CP 5621,
CP 5622 (Win 7 and higher),
CP 5711;
SOFTNET-PB DP Slave V8.2
For 32/64-bit:
Windows 7 Professional/Ultimate;
for 64-bit:
Windows 2008 Server R2
German/English
• Single License for one installation 6GK1704-5SW08-2AA0
SOFTNET-DP Slave Edition 2008
(V7.1)
For 32-bit
Windows XP Professional SP2/3;
Windows 2003 Server R2, SP2;
Windows Vista Business/
Ultimate SP1; Windows 2008 Server;
English/German
• Single License for one installation 6GK1704-5SW71-3AA0
Software Update Service 6GK1704-5SW00-3AL0
For 1 year with automatic extension;
requirement: current software version
Upgrade
• From Edition 2006 to SOFTNET-DP
Slave Edition 2008 or V8.1 6GK1704-5SW00-3AE0
• From V6.0, V6.1, V6.2 or V6.3 to
SOFTNET-DP Slave Edition 2008
or V8.1
6GK1704-5SW00-3AE1
ST80_2013_EN_Kap05.book Seite 228 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — PROFIBUS
OPC server for PROFIBUS
5/229
Siemens ST 80 / ST PC · 2013
Overview
System integration with OPC server
Standardized, open multi-vendor interface
Interfacing of OPC-capable Windows applications to DP, FMS,
S7 communication and open communication
(SEND/RECEIVE) based on the FDL interface
OPC Scout with browser functionality as an OPC client and
OCX-Data-Control/.NET Data Control for simple OPC client
creation
The relevant OPC servers are supplied with each communi-
cation software package
OPC XML DA
as Web service
SIMATIC S5
(SEND/RECEIVE only)
SNMP
OPC server
PN IO OPC serverS/R OPC server
DP OPC server
FMS OPC server
DP protocol
FMS protocol
S7 OPC server
S7 communication
Open
communication
(SEND/RECEIVE)
PC/Windows PC
SIMATIC NET
OPC-Scout
WinCC
OPC-Client
Microsoft Office
OPC-Client
OPC XML
Webclient
G_IK10_XX 50700
Internet
Intranet
Industrial Ethernet
PROFINET
S7-400
S7-300
SIMATIC S5
ET 200pro
PROFIBUS
SNMPPROFINET
COM/DCOM
OPC UA
PC
PC
SIMATIC S7-1200
S7-1200
ST80_2013_EN_Kap05.book Seite 229 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
PC-based Automation
Communication — PROFIBUS
S7 OPC Redundancy for PROFIBUS
5/230 Siemens ST 80 / ST PC · 2013
5
Overview
OPC (Openness, Productivity & Collaboration) is a
standardized, open, and vendor-independent interface that is
widely used in automation. OPC UA (Unified Architecture) is the
result of consistent further development of this standard, offering
additional functions such as security or redundancy.
S7 OPC Redundancy is a software product compliant with the
OPC UA standard that enables the redundant configuration of
OPC UA servers to SIMATIC S7. The availability of automation
data to operator control and monitoring systems is guaranteed
thanks to the redundant use of OPC UA servers. This requires
neither additional cabling for synchronizing the redundant
OPC UA servers, nor additional programming overhead in the
PC. The OPC UA servers are synchronized via high-perfor-
mance Industrial Ethernet network access points at 10/100 and
1000 Mpbs. S7 OPC Redundancy represents an integrated
customer solution for all SIMATIC NET S7 SOFTNET and
HARDNET software products in the automation world.
Ordering data
Order No.
S7 OPC Redundancy
Software for redundant
OPC servers, Runtime software,
software and electronic manual on
CD-ROM, license key on USB stick,
Class A
S7 OPC Redundancy V8.2
for PROFIBUS
For 64-bit
Windows 2008 server R2;
English/German
• Single License for one installation 6GK1706-5CW08-2AA0
Software Update Service 6GK1706-5CW00-3AL0
For 1 year with automatic extension;
requirement: current software
version
ST80_2013_EN_Kap05.book Seite 230 Freitag, 2. August 2013 3:04 15
© Siemens AG 2013
Siemens ST 80 / ST PC · 2013
6
Customized Automation
6/2 Customized Automation
6/2 Introduction
6/4 Customized adaptations
6/4 Introduction
6/6 Customized hardware
6/7 Design products
6/10 OEM products
6/11 Flexible front design concept
for HMI products
6/13 MP 277 8" Touch control console
6/14 SIMATIC HMI Net Panel
6/17 Turnkey products
6/18 HMI operator stations
6/20 Customized software
6/21 Remote Operate Software
6/22 SIMATIC KNX/EIB2S7
6/24 S7 OpenModbusTCP
6/26 Examples of sector products
6/27 Renewable energy
6/28 Solar systems
6/29 Wind farms
6/30 Automotive industry
6/30 HMI operator stations
6/32 Front panel 15" with motion keys at side
6/33 Mobile Panel 277 10" Remote Operate
6/36 General machine construction
6/36 Front panel 15" Touch and Key
for Panel PCs, resistant to honing oil
6/38 Flat Panels, 10.4" for Panel PC
6/39 Food and beverages industry/
pharmaceuticals
6/41 Panels and Panel PCs
with stainless steel front
6/44 HMI Panels as rear-mounted devices
6/46 Flat Panels with stainless steel front
6/48 HMI stainless steel operator stations
6/49 Oil & gas/chemicals/shipbuilding
6/50 MP 377 15" Touch daylight readable
ST80_2013_EN_Kap06.book Seite 1 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Introduction
Customized Automation
6/2 Siemens ST 80 / ST PC · 2013
6
Overview
Customized Automation - Hardware
Customized Automation - overview
With Customized Automation, field-proven SIMATIC,
SIMATIC PC and SIMATIC HMI standards are transferred to
individual products and systems – tailored precisely to the
customer's requirements. The portfolio covers the hardware
and software range, as well as support and logistics.
OEM products
Design products
Standard products
Turnkey products
Software products and
customer-specific software images
G_ST80_XX_00557
SIMATIC standard products
SIMATIC controller SIMATIC HMI SIMATIC IPCs
Design products
OEM products
Turnkey products
Customized
Service & Support
G_ST80_XX_00441
Customized Automation
Customized Hardware
Customized Software Customized Logistics
ST80_2013_EN_Kap06.book Seite 2 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Introduction
Customized Automation
6/3
Siemens ST 80 / ST PC · 2013
Benefits
Time savings
you can use comprehensive customization know-how and our
long years of experience with the SIMATIC components
you do not have to build up any additional know-how, and you
can concentrate completely on your own core competence
Increase in profitability
you invest your money and resources selectively in your core
competence
you implement reliable material requirements and logistics
planning, tailored to your needs, thanks to our logistics
services
you have maximum investment security thanks to maximum
quality, long-term availability and continuity with SIMATIC,
SIMATIC PC and SIMATIC HMI
you save unnecessary costs thanks to tailor-made solutions,
and you benefit from the global service & support concepts
with SIMATIC, SIMATIC IPC, and SIMATIC HMI
Increase in competitive edge for the machine
you use SIMATIC products that correspond to the highest
quality standards, offer optimal performance, and thus boost
your productivity by minimizing standstill times
you receive customized products with Customized
Automation that fit outstandingly well into the "Totally
Integrated Automation" (TIA) concept
you stand out not only for exceptional technology but also for
individual design of your machine, for example, by printing a
logo on the front of the enclosure.
Customized hardware:
Customized products are modified SIMATIC HMI standard
products. According to the necessary degree of modification of
the hardware, these types of product are separately identified
as:
Design products
•OEM products
Turnkey products
The customer-specific modifications are available in all perfor-
mance classes, starting with Push Button Panels or Key Panels,
Basic Panels, Comfort Panels up to Rack/Box/Panel PCs.
Customized software:
In the case of customer-specific products, the software can also
be individually installed. This includes the generation of
operating systems and also the integration and installation of
driver software and images – for complete, turnkey systems.
Customized software products:
Remote Operate Software
for implementation of multi-user systems with HMI IPC and
clients on the basis of MP 377 and HMI IPC477
SIMATIC KNX/EIB2S7
enables integration of actuators/sensors on a KNX/EIB bus of
building automation systems into SIMATIC S7
Open MODBUS for SIMATIC systems
provides the capability of connecting systems from various
manufacturers to SIMATIC automation systems
Customized products from various industries
SIMATIC HMI products are provided with additional features in
order to facilitate optimum use in specific sectors of industry.
Stainless steel front panels for the food, beverages and tobacco
industry are one such example. With the exception of their front
panels, the devices are identical to standard products in respect
of function and technology.
We can offer products for the following industries:
Renewable energy
Automotive industry - HMI for factory automation
General machine construction
Food and beverages industry/pharmaceuticals
Oil & gas/chemicals and shipbuilding
Customized products for various industries are developed and
produced in conjunction with a customized product agreement.
More information
More information is available in the Internet at
http://www.siemens.com/hmi-oem
ST80_2013_EN_Kap06.book Seite 3 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Introduction
Customized adaptations
6/4 Siemens ST 80 / ST PC · 2013
6
Overview
Our SIMATIC IPC Customization Centers convert the field-
proven SIMATIC IPCs into individualized products and systems
for you – tailored precisely to your specific needs. Our portfolio
ranges from individualized design, through software installation
and special tests or certifications, right up to just-in-time
delivery. This provides you with more time for your own projects
while improving your profitability and thus your competitive
advantage.
Customized SIMATIC IPC -
precisely tailored to your requirements
Benefits
You gain time because you ...
can benefit from our comprehensive customization expertise
and many years of experience regarding industrial PCs.
do not have to create industrial computer-specific expertise
and can therefore fully concentrate on your core compe-
tencies.
You increase profitability because you ...
invest your money and resources specifically in your core
competencies.
implement a reliable inventory control and logistics planning
as required thanks to our logistics services.
ensure maximum investment protection due to maximum
quality, long-term availability and continuity with SIMATIC IPC.
avoid unnecessary costs due to custom-tailored solutions.
benefit from worldwide Service & Support concepts with
SIMATIC IPC.
You increase your competitive edge because you ...
use industrial PCs that conform to the highest quality
standards, offer optimum performance, and thus increase
productivity by minimizing downtimes.
use customer-specific SIMATIC IPCs that are optimally
integrated in the Totally Integrated Automation (TIA) concept.
not only stand out due to extraordinary technology, but also
due to the customized design of your machine, e.g. by
printing a logo on the device front of the industrial PC.
Application
Customized hardware -
Individual in design and configuration
Customized design
Inscription or printed logo, e.g. on the front cover of the
enclosure, matches your corporate design requirements
Custom color design of enclosure, individual enclosure
components, e.g. enclosure front and front cover – for perfect
optical integration of the PC in the operating environment
Customer-specific configuration
Optimization of the computer configuration
corresponding to the requirements of your application,
e.g. with or without PROFIBUS interfaces or optical drives
Optimal selection of the required components - with regard
to performance capability, long-term availability and compati-
bility, e.g. processor, fan, work memory, etc.
Installation of the hardware you specified – e.g. third-party
hardware such as drives and PC cards or customized,
supplied hardware
Customized software – operating systems, drivers, image
Generation of operating systems
E.g. for Windows XP embedded,
and the RMOS3 real-time operating system from Siemens
For customer-specific preinstalled LINUX operating system
1)
Integration and installation of driver software and image
storage
E.g. for additional plug-in cards, controllers and memory
media
For complete, turn-key systems
1)
Suitable for specific LINUX versions in accordance with the specifications
of the Siemens manufacturer's declaration "Suitable for LINUX", see
http://www.siemens.com/simatic-pc/suitable-for-linux
Driver development
Image generation
Requirements
analysis, concept
development, solution
determination
Long-term availability
Demand-oriented
manufacturing
Individual labeling
Adaptable packaging
and delivery
Requirements
analysis, concept
development, solution
determination
Customized project
monitoring
Individual repair
concepts
G_ST80_XX_00558
Customized
Service & Support
Customized Software
Customized Logistics
ST80_2013_EN_Kap06.book Seite 4 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Introduction
Customized adaptations
6/5
Siemens ST 80 / ST PC · 2013
Application (continued)
Customized service and support
Pre-sales and after-sales support
Requirements analysis, concept creation, solution generation
Competent project support from the offer through to delivery
and beyond
Individual repair concepts with worldwide Siemens service
network with 190 branches and 33 repair centers
24-hour product support over the SIMATIC Hotline
System test of hardware and software, e.g.
EMC chamber – Test for electromagnetic compatibility
Thermal simulation – Thermal simulation and heat imaging
camera to detect heat pockets
Heat test – Testing of all components in a 36-hour heat test at
40 degrees Celsius in a heated cabinet
Stress test – Test for high vibration/shock loading, specially
for CPU, graphics, memory, modules, etc.
Product Equipment Data (PED)
Online tool PED (www.siemens.com/ped) – For easy,
systematic identification and management of device compo-
nents. It shows you the most important components of your
equipment (delivery status) easily and quickly and supports
you worldwide in the event of a servicing requirement with the
procurement of suitable replacement parts.
"Tempesting" (SITEMP)
TEMPEST (Temporary emanation and spurious trans-
mission) – For protecting compromising data from listening-in
attacks by means of electromagnetic radiation
Series measurements and certification of special PC hardware
according to the standards of the German Institute for Safety
in Information Technology (BSI) for radiation safety
E.g. PC for processing highly sensitive research and devel-
opment data
Certification and approval of hardware and software
e.g. UL and CE industry certification
On-site service – e.g. for plant failure, on-site repairs, product
upgrades
Customized logistics
Availability tailored to your requirements
Configuration and design freeze – Individual availability
agreements for unchanged hardware and software versions of
the products (image compatibility)
Replacement parts in centralized or decentralized spare
parts storage – For individually agreed periods or, where
applicable, last-time buying and storage of components
License authorization for discontinued software, e.g. for
Microsoft operating systems such as Windows NT, MS DOS
Tailor-made right down to the detail
Change notices – Individual agreements for customer infor-
mation management, e.g. product discontinuation, version
updates, phase-out announcements
Individual labeling – On the industrial PC and/or product
packaging, e.g. customized item/device/inventory numbers,
warehouse barcodes or packing and safety instructions
Supply of accessories – e.g. adapter cables, keyboards or
accompanying documents and manuals
Individual logistics solutions
Kanban delivery – We supply according to the requirements
of the organization units in the production process of our
customers who organize their production process control in
accordance with the Kanban principle. This shortens the
throughput time and reduces inventories.
Just in time – We reduce the inventories and throughput
times of our customers by supplying the hardware manufac-
tured customer specifically at exactly the time when they need
them in the production process or in the logistics chain
Reusable packaging – Better than recycling!
The packaging is collected from our customers after the
specially manufactured hardware has been unpacked and
reused for transporting the next delivery. Packaging material
is saved to the advantage of our customers and the
environment.
More information
You can find further information at:
Internet: http://www.siemens.com/customized-pc
Email: customized-pc.automation@siemens.com
ST80_2013_EN_Kap06.book Seite 5 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Customized hardware
Customized hardware
6/6 Siemens ST 80 / ST PC · 2013
6
Overview
Customized products are modified
SIMATIC HMI standard products
A distinction is made according to the degree of hardware
modification:
Design products
•OEM products
Turnkey products
The Open Platform Program is available for customized software
solutions.
With these possible modifications, products are planned for
special customer requirements in the various industries.
Customized products from various sectors
Further information can be found on the Internet at:
http://www.siemens.com/hmi-oem
Proportion of customized modifications on the individual
product types:
Customized hardware:
Design products
Customized design means modifying the design and visual
impact of the SIMATIC, SIMATIC HMI and SIMATIC IPC products
for seamless adaptation into the customer's individual machine
and plant design and special operator philosophy.
The modification options are:
Changing the company logo and and device type designation
Changing the keyboard color scheme, the key labeling, or the
key symbols
Changing the enclosure color (front frame)
Design products are fully compatible with the standard products
in technology and functionality, and can thus be fully integrated
into the Totally Integrated Automation environment. Identical
technology enables, for example, replacement using standard
devices in the event of a fault in case the machine or plant
supplier does not currently have a customized product in the
spare parts warehouse.
OEM products
Product modifications for OEM (Original Equipment Manufac-
turer) customers are suitable for individual, industrial automation
solutions that cannot be fulfilled with the help of standard
products, or can only be handled with design-modified panels.
OEM products are individual solutions based on SIMATIC
standard components. They are specified, offered, developed
and supplied individually in consultation with the customer.
For this purpose, we simply combine the standard components,
the customized components, and the additionally required
software function expansions into a SIMATIC OEM device, as
with a modular system.
Modification options:
Changes in the keyboard layout, key size/design and key
arrangement
Freely definable front dimensions and mechanical compo-
nents
Integration into enclosure for desktop use or support arm
mounting
Different processes and memory media
Different display technologies, sizes and resolutions
Distributed configuration
Additional modules or interfaces
Freely selectable Windows versions as operating systems,
pre-installed SIMATIC software packages
However, new OEM products can frequently be based on
already implemented OEM products for efficiency and cost
savings (see product examples). The end product is then repre-
sented as a customized modification of an existing OEM
product.
Our OEM devices are available in every performance class -
starting from OEM Push Button Panels, through Text Displays,
Touch and Operator Panels, right up to multifunctional platforms
(MPs) and PCs in rack/box/panel versions with extensive
changes to hardware, equipment and installed software.
Customized OEM products are developed and produced in
various stages in accordance with quality standards.
Turnkey products
Customized turnkey products are ready-to-install and ready-to-
use products from a single source that have been combined and
assembled to customer specifications and in accordance with
the specific technical requirements of HMI products. With the
turnkey products, the HMI products are tested and supplied,
e.g. as complete operator stations, that is, mounted and wired in
special enclosures, and installed with the specified software:
Optimized HMI operator station: ergonomic, functional,
certified and tested
Optimal mechanical installation of the devices with defined
high degree of protection
Flexible in installation and wiring
Variable mounting options
(support arm, stand, wall-mounting)
Certified in accordance with VDE, CE and UL
(in accordance with agreements and statutory conditions)
Vibration-tested and shock-tested
Packaged for safe transport
Tested heat balance with passive cooling and with specified
ambient temperature
Customer-specific software suite with electronic software
release management
Customized SIMATIC turnkey products offer standard product
quality from a single source and are ready-to-install and ready-
to-use.
Standard
Products
Design
Products
OEM
Products
Turnkey
Products
G_ST80_XX_00296
10% 15% 25%
ST80_2013_EN_Kap06.book Seite 6 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Customized hardware
Design products
6/7
Siemens ST 80 / ST PC · 2013
Overview
SIMATIC HMI products in individual corporate design for
machines and plants are important for customers when making
purchasing decisions. Seamless integration of the HMI devices
in operation and ergonomics as well as in the overall machine
and plant design is especially important.
The HMI devices with customer-specific design fully meet these
requirements.
The following design changes are possible depending on the
variant:
Extremely fast design implementations
Implementation of even low minimum quantities
(no general agreements)
Photo-realistic design up to 600 dpi
Color gradients in the logo
The following changes (design variants) are possible:
Version A:
Inserting the individual company logo instead of the
Siemens logo and changing the type designation
Version B:
Version A + changing keyboard colors, key labels, symbols
and background color
Version C:
Version B + changing the frame color for the front frame
Digital Express design:
Version B in photo-realistic print quality, for small quantities
with accelerated execution of the project
The following applies for variants A-C:
A contractually agreed minimum quantity per year is
necessary
Stockpiling in accordance with contract
First deliveries approximately 8 weeks after design start
Selected SIMATIC HMI Touch devices are available in Digital
Express design thanks to adapted production procedures.
The following applies for implementation in
Digital Express design:
Without contractual obligation
Even small ordering quantities
Significantly reduced implementation time
Photo-realistic print quality
The SIMATIC HMI products with customer-specific design are
completely identical to the standard products in respect of
technology and function. This similarity makes it possible to
respond flexibly to almost any need situation. In this way, a
machinery and plant supplier can quickly switch to standard
products if in the event of a fault there are no HMI design units
available in the spare parts inventory.
This flexible production makes cost-effective design products
possible even in small ordering quantities. The devices are
manufactured in the series production factory and are subject to
the same quality requirements as standard devices.
The professional creation of customized designs is handled by
the SIMATIC HMI Design Center.
The following services are offered to the customer:
Support in the selection of suitable design variants
Direct, specialist coordination and customer consultation in
the selection of appropriate typefaces, colors, and standard
symbols, e.g. to optimize machine operation
Creation of a customer-specific design draft
Short response times, first design draft around 5 days after
design start
Obtaining required customer approval
There are no one-off project costs for these services of the
SIMATIC HMI Design Center (see "Additional information" for
details). A quotation will be made for any further changes and
consultation services.
Regarding customized design, it is also possible to match the
colors of various SIMATIC HMI design devices in order to
achieve a uniform corporate identity. The associated costs will
be calculated according to actual requirements.
Benefits
Seamless adaptation to the customer's machine and plant
design and special operating philosophy
No restrictions in ergonomics compared with a standard
product
Even small quantities of design products may be ordered
Replaceable and fully compatible with the standard devices in
terms of:
- Functions and interfaces
- SIMATIC HMI configuration software
- Enclosure and installation dimensions
- Logistics and service, identified repairs
UL and CE certification, more upon request
ST80_2013_EN_Kap06.book Seite 7 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Customized hardware
Design products
6/8 Siemens ST 80 / ST PC · 2013
6
Ordering data
According to
size of display Device type Order No. of
basic product Minimum order
quantities
Normal design
Variant A/B
Minimum order quantities
per order
Express design
Touchscreen
7 inch HMI TP700 Comfort 6AV2124-0GC01-0AX0 75 3
TP 177 6" DP mono 6AV6642-0BC01-1AX1 4
TP 177 6" DP/PN color 6AV6642-0BA01-1AX1 4
9 inch HMI TP900 Comfort 6AV2124-0JC01-0AX0 75 3
12 inch HMI TP1200 Comfort 6AV2124-0MC01-0AX0 50 3
MP 377 12" Touch 6AV6644-0AA01-2AX0 3
MP 277 10" Touch 6AV6643-0CD01-1AX1 3
15 inch HMI TP1500 Comfort 6AV2124-0QC02-0AX0 50 on request
MP 377 15" Touch 6AV6644-0AB01-2AX0 3
HMI TP1500 Basic color PN 6AV6647-0AG11-3AX0 50 on request
19 inch HMI TP1900 Comfort 6AV2124-0UC02-0AX0 50 on request
22 inch HMI TP2200 Comfort 6AV2124-0XC02-0AX0 50 -
Key
3 inch HMI KP8 PN, Key Panel 6AV3688-3AY36-0AX0 on request on request
HMI KP8F PN 6AV3688-3AF37-0AX0 on request on request
HMI KP300 Basic mono PN 6AV6647-0AH11-3AX0 200 on request
4 inch HMI KTP400 Comfort 6AV2124-2DC01-0AX0 100 on request
HMI KP400 Comfort 6AV2124-1DC01-0AX0 100 on request
HMI KTP400 Basic mono PN 6AV6647-0AA11-3AX0 200 on request
7 inch HMI KP700 Comfort 6AV2124-1GC01-0AX0 75 on request
HMI KTP600 Basic mono PN 6AV6647-0AB11-3AX0 200 on request
HMI KTP600 Basic color DP 6AV6647-0AC11-3AX0 200 on request
HMI KTP600 Basic color PN 6AV6647-0AD11-3AX0 200 on request
9 inch HMI KP900 Comfort 6AV2124-1JC01-0AX0 75 on request
12 inch HMI KP1200 Comfort 6AV2124-1MC01-0AX0 50 on request
HMI KTP1000 Basic color DP 6AV6647-0AE11-3AX0 75 on request
HMI KTP1000 Basic color PN 6AV6647-0AF11-3AX0 75 on request
15 inch HMI KP1500 Comfort 6AV2124-1QC02-0AX0 50 on request
ST80_2013_EN_Kap06.book Seite 8 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Customized hardware
Design products
6/9
Siemens ST 80 / ST PC · 2013
Ordering data (continued)
For all other products not listed here, please inquire directly.
More information
Ordering information
Explanation of the tables with selection and order data:
"Device type" and "Order No. of the associated basic product"
"Type specification" and "Order No." of the HMI standard
product to be modified.
Start of delivery of a design variant cannot commence less
than 4 months after the start of delivery of a standard device.
"Design variant"
Type of modification required, according to design variants
"Minimum quantity"
In order to be able to offer high-quality products at a compet-
itive price in the global market, there must be a lower limit to
the annual quantity and a minimum order quantity.
The possible design devices with the associated minimum
quantities are listed in the overview tables.
Prices and one-off costs
An additional amount over the price of the standard device is
charged for the customized design device.
There are no additional costs for a one-off design
(without Change Requests).
Processing
A special order processing is required for the customized
design. Various approval steps by the customer are to ensure
that the end product meets the customer's expectations. The
orders are processed, like standard orders, via the Logistic
Center Nuremberg (LZN). Orders and deliveries of 1 unit or more
depending on the version or contract are possible!
Repairs/spare parts storage
Only identified repairs are carried out.
The customer-specific spare parts required for this purpose
(device front panels) are to be stored and made available by the
customer on expiry of the warranty period or on termination of
supply.
Contacts
Please contact your local/national SIMATIC HMI representative
(visit our Internet site for more information)
Further information can be found on the Internet at:
http://www.siemens.com/hmi-oem
According to
size of display Device type Order No. of
basic product Minimum order
quantities
Normal design
Variant A/B
Minimum order quantities
per order
Express design
Touch/Monitor/Key
7 inch IPC277D Touch depending on the configuration 50 2
9 inch IPC277D Touch depending on the configuration 50 2
12 inch Flat Panel Touch or Monitor depending on the configuration 50 on request
IPC277D Touch depending on the configuration 50 2
Panel PC Touch or Key depending on the configuration 50 on request
ITC1200 6AV6646-1AA22-0AX0 75 on request
15 inch Flat Panel Touch or Monitor depending on the configuration 50 on request
Flat Panel Touch PRO 6AV7861-5TB10-1BA0 50 on request
IPC277D Touch depending on the configuration 30 on request
IPC477C Touch PRO depending on the configuration 30 on request
IPC477C Touch depending on the configuration 30 2
IPC677C Touch depending on the configuration 30 2 (USB)
Panel PC Touch or Key depending on the configuration 30 on request
ITC1500 6AV6646-1AB22-0AX0 30 on request
19 inch Flat Panel Touch or Monitor depending on the configuration 30 on request
Flat Panel Touch PRO 6AV7861-6TB10-1BA0 30 on request
IPC477C Touch PRO depending on the configuration 30 2
Panel PC Touch depending on the configuration 30 on request
ITC1900 6AV6646-1AC22-0AX0 30 on request
22 inch ITC2200 6AV6646-1AD22-0AX0 30 on request
ST80_2013_EN_Kap06.book Seite 9 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
OEM products
OEM products
6/10 Siemens ST 80 / ST PC · 2013
6
Overview
HMI product modifications for OEM customers are suitable for
complex industrial automation tasks that cannot be imple-
mented using standard products.
OEM devices are available in all performance classes: from
OEM Push Button Panels through Micro Panels, Panels and
Multi Panels right up to Panel PCs as well as Rack and Box
PCs - with far-reaching changes in hardware, equipment and
software.
The following modifications are possible:
- Changes to keyboard layout: Number of keys,
key size/design and key layout
- Freely definable front dimensions and mechanical compo-
nents
- A variety of processors for customized performance
- A variety of memory media and capacities
- Installation of function cards
- Display technologies, sizes and resolutions
- Options such as direct key modules
- Distributed configuration of Panel PCs
- Housings for desktop, stand or support-arm versions
(operator station concept)
- Additional modules or interfaces, of course always complete
with the necessary device drivers
- Selectable Windows operating systems
- Preinstalled SIMATIC software and customized software
packages
- additional functions due to PCIe slot
- Frontplate design in color and labeling of the interfaces
- Large number of interface options in the configurator in a
very small space
Benefits
The SIMATIC HMI OEM concept represents "customizing at its
best":
Your requirements, based on sector and application know-
how, combined with our experience in the development of
HMI devices of all performance classes, result in tailor-made
solutions at a fair price.
Customized OEM products are developed in defined stages
in accordance with quality standards and produced using
standard plant facilities - always in close cooperation with the
customer.
Users in various industries, including regenerative energies,
the automotive industry, the food, beverages and tobacco
industries, the oil and gas industry, as well as in the plastics-
processing industry and others are benefiting from our
experience of delivering tried and tested OEM versions and
industry standards.
ST80_2013_EN_Kap06.book Seite 10 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
OEM products
Flexible front design concept for HMI products
6/11
Siemens ST 80 / ST PC · 2013
Overview
MP 377 15" Touch OEM according to flexible front-mounting
concept for injection molding machines
Customer requirements with regard to HMI devices are
extremely diverse. The flexible front-mounting concept makes it
possible to meet these diverse customer-specific requirements.
The flexible front-mounting concept enables customized front
design as well as customized layout of the operator elements.
The SIMATIC products form the technical basis of a device
developed according to the flexible front-mounting concept.
The diversity of the standard products enables integration from
the small 6" Flat Panel right up to high-performance PC
technology. The customer's own, typical operator philosophy
can also be optimally implemented since the flexible front-
mounting concept offers the wide range of operator elements –
from the classic 3SB operator elements, through short-stroke
keys, right up to membrane keyboards.
The flexible communication options with PROFIBUS or
PROFINET facilitate integration into new or existing machine
concepts. Fail-safe operation can be implemented by using
PROFIsafe components. To meet individual customer require-
ments, a device built in accordance with the flexible front-
mounting concept can be designed as a built-in device or as a
stand-alone unit. If designed as a stand-alone unit, care is taken
to make the enclosure slimline and modern in appearance.
Benefits
The flexible front-mounting concept allows customized HMI
solutions based on the field-proven SIMATIC components.
A project using the flexible front-mounting concept is the
obvious choice especially for the following customer require-
ments:
Customized integration of operator elements and display
systems
High integration density of SIMATIC products
Demand for customized design and layout
Demand for optimal integration into plants and machinery
Compact design as stand-alone product in enclosure
Compact design as built-in unit at the machine level
Use of field-proven components and thus also optimized time-
to-market
These requirements can be implemented for the customer by
means of a flexible front-mounting concept.
The general conditions for a project using the flexible front-
mounting concept are:
Minimum unit quantity 100 p.a.
Project agreement
- With unit quantity start-up forecasting and annual unit
quantities for the project
- for funding development costs
- Key project dates and standard start-of-delivery dates
- Logistics with delivery times
Application
The industrial environment imposes diverse requirements on
technology and design. Thanks to its variable and modular
approach, the flexible front-mounting concept opens up diverse
options for re-combining SIMATIC standard components in a
compact device configuration with individualized design and
layout. The possible uses are thus diverse and universal.
ST80_2013_EN_Kap06.book Seite 11 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
OEM products
Flexible front design concept for HMI products
6/12 Siemens ST 80 / ST PC · 2013
6
Design
The flexible design and the use of standard SIMATIC products
make it possible to meet just about every technical requirement
with regard to customized HMI. Components that can be
combined to form an individualized HMI are listed below:
Basic devices:
Flat Panels with different screen diagonals
Thin Client
Comfort Panel
Panel PC
Operator control:
Touch functionality
Keys functionality with
- 3SB elements
- Short-stroke keys
- Membrane keys (also illuminated)
Keyswitches etc.
Additional elements:
High-speed keys via PROFINET
Emergency stop (also PROFIsafe)
Front USB etc.
Design:
Stand-alone (IP65 at front, <= IP54 at rear)
Built-in unit (IP65 at front; IP20 at rear)
Slimline enclosure design
Device connection:
With support arm via VESA 100 on rear of enclosure
Connected at the edges using hinges
Installation in machinery
Design:
Customized design
Customized key layout
Customized symbols and logos
More information
Quotation preparation
Product specification in accordance with customer
requirements. Quotation drafted by SIMATIC HMI specialists.
Determining:
One-time project costs
Costs for sample devices/prototypes
Standard unit prices
General conditions (product agreement)
There must be a minimum limit to the annual unit quantity/
purchase quantity (minimum quantity per version: from 100) and
this must be agreed with the project customer. Customized
products can only be ordered in conjunction with a product
agreement. A customer-specific order number is allocated
during the product agreement process.
Contacts
Please contact the HMI representatives of your Siemens sales
office/national company.
Additional information in the Internet is available at:
http://www.siemens.com/hmi-oem
Flexible front-mounting concept project development and
service
Customized projects using the flexible front-mounting concept
are developed and produced in different steps in accordance
with quality standards. Prototypes are created to test products.
Once the devices have been approved by the customer, they
undergo certification and are introduced into the production
process.
Devices are produced in standard product factories, ensuring
observation of customer quantity forecasts. For this purpose,
individual quantity forecasts are exchanged with the customer.
In the event of questions and problems, customers can contact
our worldwide 24-hour SIMATIC Customer Support.
Customized products can only be ordered in conjunction with a
product agreement.
The following points are defined in the product agreement:
Delivery and pricing
Logistics - annual volume, purchase quantity, delivery batch
volumes
Spare parts
Service
Repairs/spare parts storage
The repair concept is also agreed with the customer. The
necessary customized spare parts (device fronts) are defined
here and offered to customers for their products after completion
of delivery.
ST80_2013_EN_Kap06.book Seite 12 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
OEM products
MP 277 8" Touch control console
6/13
Siemens ST 80 / ST PC · 2013
Overview
OEM MP 277 8.4" Touch
Benefits
Heavy-duty, die-cast aluminum housing
Easy mounting on patient table with clamping device
Low space requirements
Extremely good readability
Simple operation
Joystick can be connected optionally on left or right
Ethernet communication
Application
The OEM MP 277 8.4" Touch is suitable for use as a control
console for coronary angiography systems in the medical field.
Technical specifications
Rugged die-cast aluminum housing
8.4'' TFT display
800 x 600 pixel resolution
Operation by means of touch screen and optional joystick
Customized application and customized WinCE image
Degree of protection on front: IP65.
Option
Different housing color
Ordering data
Order No.
Customized products can only be ordered in conjunction with a
product agreement. The following points are defined in the
product agreement:
Status: Released for delivery
Project runtime: None
Non-recurring costs: None
Minimum quantity: 200
More information
Additional information is available in the Internet under:
http://www.siemens.com/hmi-oem
OEM MP 277 8.4" Touch On request
ST80_2013_EN_Kap06.book Seite 13 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
OEM products
SIMATIC HMI Net Panel
6/14 Siemens ST 80 / ST PC · 2013
6
Overview
Professional display system for continuous,
maintenance-free operation
The SIMATIC HMI Net Panel is multifunctional when it comes to
rugged, large-scale display applications for industrial areas, as
it is ideal for production plants and control stations or for trade
fairs and information points visited by the public.
The Net Panel is based on a reliable industrial PC of the
SIMATIC IPC series and is designed for 24-hour, maintenance-
free operation in an industrial environment. It is extremely flexible
in operation and can be used as a stand-alone solution or in the
network as a complete industrial display system comprising
several Net Panels. For applications that require audio output,
variants of the Net Panel are available with audio modules and
speaker equipment.
Remote Control for setting up the SIMATIC HMI Net Panel
The Remote Control Software included in the scope of delivery
allows the Net Panel to be operated either locally or via the
network. It enables the brightness and volume to be adjusted
and the backlight to be switched off.
For self-diagnosis the device temperature can be indicated.
The Remote Control software allows the function to be shut down
to prevent burn-in effects (anti-image sticking). The anti-image
sticking function should, however, only be deactivated when
adequate measures have been implemented on the Net Panel to
prevent image sticking.
Remote Operate as client/server solution for industrial
display systems (optional)
When Remote Operate is installed, four virtual graphics cards
can be set up on one IPC and presented as extended desktops.
On every SIMATIC HMI Net Panel, a Remote Operate client is
installed that is assigned to a virtual graphics card. The different
screen contents are distributed to the virtual graphics adapters
using the HMI software WinCC. If the Net Panel is equipped with
sound, MP3 and Wave files can be sent to a specific Net Panel
where they can be played, using an easily accessible function.
Benefits
High degree of system availability due to maintenance-free
industrial design with IP65 degree of protection for continuous
24-hour operation
High security of investment due to rugged industrial products
from SIMATIC that will remain available over the long term
Reduced costs through low-wear and power-saving LED
backlight and anti image sticking function
Easy, cost-efficient integration in a standard network
environment without VGA/DVI/HDMI extensions or expensive
video signal extenders
Optionally available with audio module and loudspeaker for
sound output
Flexible mounting on support arm systems, wall and ceiling,
as well as back-to-back mounting and with an angle of incli-
nation of up to 20° from the vertical
Remote Control Software (locally on the device and remotely
from the network) for the easy parameterization of
-Brightness
- Deactivation of backlighting
- Status messages of display
- Speaker control
Supported by WinCC flexible 2008 SP2 or higher
(IPC427C with 1920 x 1080 resolution)
Application
The SIMATIC HMI Net Panel is designed for demanding large-
scale displays in the industrial environment.
It is based on rugged, reliable PC technology with interfaces for
easy, cost-efficient integration in existing networks and offers
maximum flexibility for positioning and mounting.
The large LCD display with LED backlight, round-the-clock
operation, and full PC openness make the large-scale display
ideal for use as an industrial manufacturing display, add-on
system, multimedia display, process visualization system,
railway station and airport display (check-in, gate, baggage
claim, advertising display) or at trade fairs, in shopping centers,
hotels, museums and more.
Design
The SIMATIC HMI Net Panel is a rugged display system with an
integrated industrial PC and optional audio and loudspeaker
equipment.
LCD display with 1920 x 1080 pixel full HD resolution
Power saving and long-life LED backlight
Integral SIMATIC industrial PC
Rugged and attractive device design with reduced enclosure
depth
Degree of protection IP65 all-round, industry compatible
Solid, shatterproof front pane of 6 mm laminated glass
Anti-glare front pane resistant to welding beads
Safety eyebolts (removable as required) for additional
protection against dropping in suspended installations
Optional: adapter for Rose & Krieger FSK 50 support arm
system
Integrated wide-range power supply
Rear connector for 1x USB (with IP65 protective cap),
1x Industrial Ethernet (M12 4-pin with protective cap)
Rear Quick-On connection for integrated 100 - 240 V power
supply (connector included in scope of delivery)
Rear status indicator
ST80_2013_EN_Kap06.book Seite 14 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
OEM products
SIMATIC HMI Net Panel
6/15
Siemens ST 80 / ST PC · 2013
Technical specifications
SIMATIC HMI Net Panel SIMATIC HMI Net Panel
Display
Size 46" (116 cm) LCD TFT 46" (116 cm) LCD TFT
Resolution 1920 x 1080 Full HD (16:9) 1920 x 1080 Full HD (16:9)
Colors 16.7 million colors 16.7 million colors
Reading angle +/- 178° +/- 178°
Backlighting LED backlight LED backlight
Brightness Typically 400 cd/m² Typically 400 cd/m²
PC configuration
Processor Celeron M 1.2 GHz Core2 Solo 1.2 GHz
Main memory 1 GB 4 GB
Mass storage Compact Flash 4 GB 250 GB hard disk
Operating system Windows Embedded Standard 2009 Windows Embedded Standard 2009
General features
Enclosure design Industry-compatible steel enclosure, black,
powder-coated Industry-compatible steel enclosure, black,
powder-coated
Glass front Shatterproof front pane of 6 mm laminated glass,
anti-glare, resistant to welding beads Shatterproof front pane of 6 mm laminated glass,
anti-glare, resistant to welding beads
Audio (optional)
Audio module 2x 15 W audio module 2x 15 W audio module
Loudspeakers 1 pair, mounted to left and right, BOSE or alternatively
Visaton 1 pair, mounted to left and right, BOSE or alternatively
Visaton
Interfaces
USB 2.0 1x at rear (with IP65 protective cap) 1x at rear (with IP65 protective cap)
Ethernet 1x Industrial Ethernet, D-coded
(M12 4-pin with protective cap) 1x Industrial Ethernet, D-coded
(M12 4-pin with protective cap)
Power supply 100 - 230 V AC Quick-On plug connector 100 - 230 V AC Quick-On plug connector
Keyboard; mouse Connectable via USB interface
(optional USB hub recommended for commissioning) Connectable via USB interface
(optional USB hub recommended for commissioning)
Ambient conditions
Degree of protection IP 65 all-round; IP54 when USB is plugged in IP 65 all-round; IP54 when USB is plugged in
Vibration load during operation 1g outline specification 1g outline specification
Shock loading during operation 5g outline specification 5g outline specification
Ambient temperature during operation 5…45°C for 24 h operation 5…45°C for 24 h operation
Conformity
Approvals CE CE
Dimensions
External dimensions
(W x H x D in mm), weight 1138 x 681 x 130; approx. 55 kg 1138 x 681 x 130; approx. 55 kg
External dimensions (W x H x D in mm)
with BOSE loudspeaker, weight 1410 x 681 x 130; approx. 58 kg 1410 x 681 x 130; approx. 58 kg
External dimensions (W x H x D in mm)
with Visaton loudspeakers, weight 1565 x 681 x 130; approx. 57 kg 1565 x 681 x 130; approx. 57 kg
Software
HMI software Supported by WinCC flexible 2008 SP2 or higher Supported by WinCC flexible 2008 SP2 or higher
Remote Control Software For adjustment and control, locally or via network For adjustment and control, locally or via network
Special features
Continuous glass front with narrow protective frame Continuous glass front with narrow protective frame
Auto-refresh function for anti image sticking Auto-refresh function for anti image sticking
2-point mounting, M8 on left and right sides of enclosure,
75 mm spacing 2-point mounting, M8 on left and right sides of enclosure,
75 mm spacing
2x removable safety eyebolts on top of enclosure 2x removable safety eyebolts on top of enclosure
ST80_2013_EN_Kap06.book Seite 15 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
OEM products
SIMATIC HMI Net Panel
6/16 Siemens ST 80 / ST PC · 2013
6
Ordering data
Order No. Order No.
More information
Customized modification options on request. Recommended
support arm system from Rose & Krieger.
SIMATIC HMI specialists define the product modifications
precisely in accordance with customer requirements.
This is followed by drafting of a quote with:
Non-recurring costs
Prototype costs
Standard unit prices
and the marginal conditions in the form of a product
agreement (e.g. minimum quantity).
The defined device can then be ordered easily using this
product agreement and a customized order number.
SIMATIC HMI Net Panel
Intelligent large-scale display;
1920 x 1080 full HD widescreen;
1 x Industrial Ethernet interface and
1 x USB on the rear; Windows
Embedded Standard 2009; remote
control software; enclosure design
according to IP65, if plugged in at
the rear IP54; includes Quick-On
connector for 100 - 230 V power
supply; CE
• Preferred type:
46" screen diagonal,
IPC Celeron M 1.2 GHz,
1 GB RAM, 4 GB CF Card,
without speakers,
without audio module
6AV7426-0AA12-0BA0
46" screen diagonal,
IPC Celeron M 1.2 GHz,
1 GB RAM, 4 GB CF Card,
with Visaton speaker,
with audio module 2 x 15 W
6AV7426-0AA12-1BA0
46" screen diagonal,
IPC Celeron M 1.2 GHz,
1 GB RAM, 4 GB CF Card,
with BOSE speaker,
with audio module 2 x 15 W
6AV7426-0AA12-2BA0
46" screen diagonal,
IPC Core2 Solo 1.2 GHz,
4 GB RAM, 250 GB hard disk,
without speakers, without audio
module
6AV7426-0AD35-0BA0
• Preferred type:
46" screen diagonal,
IPC Core2 Solo 1.2 GHz,
4 GB RAM, 250 GB hard disk,
with Visaton speakers,
with audio module 2 x 15 W
6AV7426-0AD35-1BA0
• Preferred type:
46" screen diagonal,
IPC Core2 Solo 1.2 GHz,
4 GB RAM, 250 GB hard disk,
with BOSE speakers,
with audio module 2 x 15 W
6AV7426-0AD35-2BA0
Accessories
Support arm systems
Various support arm systems
for ceiling, back-to-back,
wall or stand mounting
are offered by Rose & Krieger.
ST80_2013_EN_Kap06.book Seite 16 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Turnkey products
Turnkey products
6/17
Siemens ST 80 / ST PC · 2013
Overview
Turnkey products are ready-to-install and ready-to-use
SIMATIC HMI products.
The benefits are found in the optimal mechanical installation of
the devices, ergonomic, functional and with tested heat balance,
and flexible in installation.
Products
HMI operator stations
HMI devices with display diagonal of 10" and more are installed
in selected enclosures to suit the function. HMI operator stations
can be used wherever it is not possible to install human machine
interface devices in a control cabinet or direct at the machine,
and where off-the-shelf, turnkey products can save on
engineering overhead. Installation of a customized image in the
devices is possible (ready-to-run). Customized SIMATIC turnkey
products offer standardized quality from a single source.
Backplane cover
The backplane cover enables the enclosure of flat HMI products
such as the HMI IPC 477C or MP 377. The backplane cover is
provided with a VESA flange on the rear. More operator elements
can be installed on the side in additional enclosures.
ST80_2013_EN_Kap06.book Seite 17 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Turnkey products
HMI operator stations for turnkey products
6/18 Siemens ST 80 / ST PC · 2013
6
Overview
Turnkey products are SIMATIC HMI products or "ready-to-run"
operator stations, i.e. pre-configured, ready for installation and
ready-to-run SIMATIC Panels Thin Client, Multi Panels or Flat
Panels and Panel PCs, installed in customer-specific enclo-
sures.
Examples are Multi Panels fitted in customized die-cast
aluminum enclosures with external keyboard; with installed
application software, ready for connection, and ready-to-run.
Application example: Multi Panel in aluminum enclosure with operator
controls, two-tier and with external keyboard
Benefits
High industrial capability thanks to an all-round rugged, tried
and tested design:
Ergonomic, technically proven and certified solutions ready
for operation
Safe operation even under difficult environmental conditions
Temperature-tested and temperature-monitored
Suitable even for special industries, e.g., stainless steel
versions for the food, beverages and tobacco industries
For high availability and a safe return on your investment
Siemens quality support, service and repair
The following issues are considered when developing the
HMI operator stations:
Optimal HMI product installation technology to eliminate
thermal hotspots and heat pockets in the housing
Calculation of actual maximum permissible ambient temper-
ature of the entire operator station in continuous duty at
location of use Data takes into account device heat dissipation
values
Ensuring the adherence to the load limits for rotary mass
storage systems and large displays verified by shock and
vibration tests on the entire operator station during operation
Adherence to legal regulations (certifications)
Determination and testing of required degrees of protection
and EMC measures
Assurance of surface quality along with its abrasion and
chemical resistance
To the greatest possible extent, passive technology provides
the basis for all measures to improve the suitability of use of
the operator stations in specific environments (e.g., no active
air conditioning). The aim is to ensure durability and fault-free
operation with minimum maintenance.
Application
Complete HMI operator stations can be used wherever
HMI devices cannot be installed in a control cabinet or directly
at the machine. Operator stations are suitable for:
Industrial application
Near-industrial application
Use in secondary applications in food, beverage and tobacco
production
Stainless steel version in the primary areas of the food,
beverages and tobacco industries
HMI turnkey products can be used wherever prefabricated,
ready-to-run hardware and software products can be used to
save on engineering.
Design
The HMI operator station concept is based on a modular system
where HMI devices are built into selected enclosures to suit the
functionality.
HMI device enclosure for all-round protection (IP65)
Mounting possible on stand or supporting bracket
Rotation possible by means of adjusting elements
Connection option for external keyboard and mouse
Installation option for specific hardware components
Ambient temperature for turnkey products
The ambient temperature is always lower than the max. permis-
sible ambient temperature of the HMI products (temperature
values in Manual) installed in the operator station housing.
Depending on the components and version (e.g. according to
heat dissipation), permissible ambient temperatures around the
operator station will vary between 5°C and 40 °C.
Higher operator station ambient temperatures can be achieved
by applying additional cooling measures.
Function
Fatigue-free, fast operation
Operator station can be quickly adapted to different operators
Coherent, easy-to-learn operator philosophy
Rugged against shocks and vibrations in operation
Suitable device selection
(SIMATIC HMI devices from 10“ display)
Ensuring the data transfer and access to drives and interfaces
Direct operation of the machine (conventional operator
elements for direct connection to machine units)
Simple alphanumeric input
Cleaning agents taken into account
ST80_2013_EN_Kap06.book Seite 18 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Turnkey products
HMI operator stations for turnkey products
6/19
Siemens ST 80 / ST PC · 2013
Ordering data
Ordering notes
Product specifications and quotation preparations
Product specification according to customer requirements
Quotation preparation by SIMATIC HMI specialists,
specification of:
- one-time project costs
- costs for sample devices/prototypes
- standard unit prices
- general conditions (product agreement)
Processing
Customized turnkey products are developed and produced in
various stages in accordance with quality standards. Prototypes
are created to test products. Once the devices have been
approved by the customer, they undergo certification and are
introduced into the production process.
Devices are produced using standard plant facilities, ensuring
observation of customer quantity forecasts. For this purpose,
individual quantity forecasts are exchanged with the customer.
In the event of questions and problems, customers can contact
our worldwide 24-hour SIMATIC Customer Support. This is
complemented by a special OEM After Sales Support service.
Customer-specific project hotlines can be set up for bulk
quantity customers.
Customized products can only be ordered in conjunction with a
product agreement. The following points are defined in the
product agreement:
Delivery and pricing
Logistics - annual volume, purchase quantity, delivery batch
volumes
Spare parts
Service
Repairs/spare parts storage
Only identified repairs are performed. The required customer-
specific spare parts (device fronts) are to be stored and
provided by the customer upon delivery completion.
More information
Contacts
Please contact the HMI representatives of your Siemens sales
office/national company.
http://www.siemens.com/hmi-oem
ST80_2013_EN_Kap06.book Seite 19 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Customized software
Customized software
6/20 Siemens ST 80 / ST PC · 2013
6
Overview
Customized software
In the case of customer-specific products, the software can also
be individually installed. This includes the generation of
operating systems and also the integration and installation of
driver software and images – for complete, turnkey systems.
The customized software suite comprises:
Generation of operating systems
- for Windows XP embedded, for example
- and the RMOS3 real-time operating system from Siemens
- for customized LINUX installation
Integration and installation of driver software and pre-installed
images
- for additional cards, controllers, or memory media, for
example
- for completely turnkey systems
In addition, customized software products based on our
experience in the industrial automation offer an opportunity to
set up multi-user systems and industrial remote operation and
the possibility of integrating SIMATIC S7 into building
automation:
Remote Operate Software
The HMI Remote Operate Software is an industrial remote
control system based on Ethernet.
The software (server) enables the creation of a multi-user system
with HMI IPC. Up to 6 operator stations (slaves) based on clients
with MP 377 and HMI IPCs. The clients can also be assigned to
several servers.
KNX/EIB2S7
Bus systems for building management systems, such as
KNX/EIB, and a host of associated components, are used for
automation of building systems.
While controllers for the room level are used for local automation,
field-proven industrial components like SIMATIC are resorted to
in the case of more complex, higher-level automation.
Communication between the automation levels takes place over
Ethernet using special KNXnet/IP interfaces. The KNX/EIB2S7
software package provides blocks for communication between
SIMATIC S7 and building automation components. This means
message frames of the KNX bus can be processed in a SIMATIC
controller.
ST80_2013_EN_Kap06.book Seite 20 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Customized software
Remote Operate Software
6/21
Siemens ST 80 / ST PC · 2013
Application
Remote Operate Software
Panel PC with connected thin clients
Multi-user system with Panel PCs for up to 6 operator stations
based on Thin Clients with MP 377 and PC 477
Including operator lock
In one software application with identical image contents
Identical screen resolution
Excluding server operating system
Industrial remote control
- Independent of the installed software
Identical images on all devices
Automatic scaling takes place in the case of differences in
screen resolution between server and client
Resolution up to 1280 x 1024 with true color
Remote Operate Server with Windows XP Professional,
Windows XP embedded, or Windows 7
Up to 6 clients on one server
Communication via Ethernet
Designed for industrial requirements
- Automatic login
- Simple administration
- Automatic reconnect
- Permanent server/client assignment
- Administration of operator authorization
- Can be used after Windows login
- Optional key-operated switch for operator authorization
PD[&OLHQWVSHU6HUYHU
3DQHO3&
5HPRWH2SHUDWH
5HPRWH2SHUDWH
3&
5HPRWH2SHUDWH
3&
035HPRWH2SHUDWH
,QGXVWULDO(WKHUQHW
*B67B;;B
Remote Operate Clients
Remote Operate Server
ST80_2013_EN_Kap06.book Seite 21 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Customized software
SIMATIC KNX/EIB2S7
6/22 Siemens ST 80 / ST PC · 2013
6
Overview
Software for communication between SIMATIC S7 and
components of a building automation system
For using components from industrial automation in the area
of building automation
Enables the integration of actuators/sensors into a
KNX/EIB bus in automation solutions with SIMATIC S7
For transferring information from the building automation
system for automating a production plant
Benefits
Use of field-proven industrial components in the area of
building automation
Use of information from building automation for automating
production plants
Simple transfer of configuring data from the KNX configuring
tool ETS3
Automatic matching of KNX addresses with the associated
SIMATIC addresses
Use of the SIMATIC standard
Application
With rising energy awareness and increased requirements
regarding user-friendliness and security, recent years have seen
building automation facing far-reaching demands.
Bus systems for building management systems, such as
KNX/EIB, and a host of available components for these are used
for implementing the corresponding systems.
While controllers for the room level are used for local automation,
field-proven industrial components like SIMATIC are resorted to
in the case of more complex, higher-level automation.
Communication between the automation levels takes place over
Ethernet using special KNXnet/IP interfaces.
The KNX/EIB2S7 software package provides blocks for commu-
nication between SIMATIC S7 and building automation compo-
nents. This means message frames of the KNX bus can be
processed in a SIMATIC controller.
Design
The SIMATIC S7 is connected with the KNX/EIB components via
KNXnet/IP interfaces. The interfaces connect the KNX/EIB bus
with the Industrial Ethernet bus of the SIMATIC S7.
Up to 5 KNXnet/IP interfaces can be connected to a SIMATIC S7
controller Up to 7,000 group addresses can be monitored,
operated and read via these interfaces. The maximum number
of group addresses depends on the controller type and the
number of connected KNXnet/IP interfaces.
KNX/EIB2S7 supports the following CPUs of the SIMATIC S7:
ET 200
- IM 151-8 PN/DP CPU
S7 300/400
- CPU 315-2 PN/DP
- CPU 317-2 PN/DP
- CPU 319-3 PN/DP
- CPU 414-3 PN/DP
- CPU 416-3 PN/DP
•Soft PLC
- SIMATIC WinAC RTX 2008 SP 1
SIMATIC S7-300 with CP 343-1
- CPU 315-2 DP
- CPU 317-2 DP
- CPU 319-3 PN/DP
SIMATIC S7-400 with CP 443–1 Advanced
- CPU 412-2 MPI/DP
- CPU 414-2 MPI/DP
- CPU 416-2 MPI
Supported KNXnet/IP interfaces:
- N 146/2 IP router
- N 148/221 IP interface
- N 350E IP controller
- N 151 IP viewer
Mode of operation
The KNX components are parameterized with the ETS 3 software
of the Konnex organization.
The KNX/EIB2S7 Editor is based on the exported parameter-
ization data of ETS3 and evaluates the group address, data type,
name and description. It only remains to select the group
addresses that are to be received and to mark those that are to
be automatically read at initialization.
Addresses are assigned automatically by the editor. The
addresses can be viewed in the Editor or exported for documen-
tation.
The parameterization of the blocks necessary for the SIMATIC
is generated by the Editor at the click of a mouse and can
then be downloaded to the SIMATIC. The blocks contained in
KNX/EIB2S7 handle the communication on the basis of this
parameterization.
When data is received, the current values are saved in the data
blocks provided for them. The values that have been updated
are then marked. Equally, there are blocks available for the
selective reading and writing of values.
ST80_2013_EN_Kap06.book Seite 22 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Customized software
SIMATIC KNX/EIB2S7
6/23
Siemens ST 80 / ST PC · 2013
Technical specifications
Ordering data
Order No.
Representation of the data types
Data type KNX value EIS type SIMATIC
data type Representation in the SIMATIC User conversion
DPT1 BOOL EIS1 Bit TRUE/FALSE n
DPT2 1 bit controlled EIS8 Byte MSB ([0000 00XY) LSB
X = controlled
Y = Value
n
DPT3 4 bits EIS2 Byte MSB (0000 XYYY) LSB
X = Increase/decrease
Y = Step 0-7
n
DPT4 Char EIS13 Char ASCII n
DPT5 1 byte unsigned EIS14 Byte n
DPT6 1 byte signed EIS14 Byte y
DPT7 2 bytes unsigned EIS10 Word n
DPT8 2 bytes signed EIS10 Int Representation in 2s
complement n
DPT9 2 bytes float EIS5 Real Conversion implicit in the driver n
DPT10 Time of Day EIS3 DWord MSB (0000 0000/dddh
hhhh/00mm mmmm/00ss ssss) LSB
d = day 0 no day; 1-7
h = hour 0-23
m = minute 0-59
s = second 0-59
Important! No value check by the
driver
n
DPT11 Date EIS4 DWord MSB (0000 0000/000d dddd/0000
mmmm/0yyy yyyy) LSB
d = day 0-31
m = month 0-12
y = year 0-99
(0-89 = 2000-2089; 90-99
= 1990-1999)
Important! No value check by the
driver
n
DPT12 4 bytes unsigned EIS11 DWord n
DPT13 4 bytes signed EIS11 D Int Representation in 2s
complement n
DPT14 Float EIS9 Real IEEE754 n
DPT15 Access EIS12 DWord MSB (XXXX6 XXXX5/XXXX4 XXXX3/
XXXX2 XXXX1/EPDC NNNN) LSB
X = AccessCode 6-digit; 0-9;
1 nibble each
E = 1 detection error
(reading of access information code
was not successful)
P = Permission 0=not accepted;
1= accepted
D = Direction 0=left to
n
DPT16 String EIS15 String (14) Driver evaluates header of the S7
string and then generates the
14-character long EIB string.
n
KNX/EIB2S7 program package 6AV6643-7AC10-0AA1
Tas k:
Software for connecting KNX/EIB
components from building manage-
ment systems to SIMATIC S7
Type of delivery:
Editor, function blocks for
SIMATIC S7, samples,
documentation on CD
License for Editor on USB flash drive
ST80_2013_EN_Kap06.book Seite 23 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Customized software
S7 OpenModbusTCP
6/24 Siemens ST 80 / ST PC · 2013
6
Overview
Software for communication between SIMATIC S7 and
devices that support the Modbus TCP protocol
Expansion or upgrade of existing plants with SIMATIC
automation systems
Connection of controllers and systems from different
manufacturers
Benefits
Easy coupling of systems from different manufacturers
with SIMATIC automation systems over Industrial Ethernet
No specialized Modbus know-how required
Engineering with the standard tool SIMATIC STEP 7
Fast configuration with the help of a wizard
(only available for specific versions)
Application
MODBUS is a protocol that is widely used internationally, open
to all users and supported by many manufacturers. MODBUS/
TCP was developed from it for use in modern networks. This
protocol is now an open Internet draft standard that was intro-
duced by IEFT (Internet Engineering Task Force), the organi-
zation for Internet standardization. This openness means that
every manufacturer and user is able to use this protocol –
a possibility that many leading manufacturers have already
availed of. The increasing expansion of Ethernet communication
into industrial areas as well as the office environment has
extended the use of MODBUS/TCP in every sector. Heteroge-
neous system landscapes are the typical areas of use.
Design
Communication with Modbus TCP stations is performed via a
communications processor (CP) or via the integrated PN
interface of the SIMATIC S7 CPU.
A SIMATIC S7 controller can communicate simultaneously with
more than one Modbus TCP station simultaneously, depending
on the number of connection resources of the S7 CPU.
S7 OpenModbusTCP CP and Redundant V2 support the
following CPs of SIMATIC S7:
S7 300
- CP 343-1
S7 400
- CP 443-1
S7 OpenModbusTCP PN CPU supports the following CPUs of
SIMATIC S7:
ET 200
- IM 151-8 PN/DP CPU
S7 300/400
- CPU 314C-2 PN/DP
- CPU 315-2 PN/DP
- CPU 317-2 PN/DP
- CPU 319-3 PN/DP
- CPU 412-2 PN
- CPU 414-3 PN/DP
- CPU 416-3 PN/DP
•Soft PLC
- SIMATIC WinAC RTX
Mode of operation
The Modbus block functions according to the client/server
principle. The client is the active station and the server is the
passive station in the communication process. Data is
exchanged between the communication partners by means of
various different function codes. The S7 can be operated as a
client as well as a server during transmission.
In the initialization phase, it is determined on which S7 data
blocks the Modbus registers and coils should be represented.
A distinction is made between client and server functionality
during cyclic operation:
If the S7 is operating as a client, when a task is activated, a
Modbus message frame is generated from the specified
current parameters and sent to the coupling partner over the
TCP/IP connection. After the response frame has been
received and the data has been checked and found to be
consistent, the required actions, such as reading or writing
data, will be performed. Any errors that occur during evalu-
ation or processing will be indicated on the Modbus block.
If the S7 is operating as a server, the block waits for a
response frame from the client. If a frame is received from a
client, it is checked and evaluated. After the frame has been
checked and found to be consistent, the response frame is
generated and the required actions, such as reading or writing
data, will be performed. A processed request, or any errors
that occur during evaluation, will be indicated on the Modbus
block.
MODBUS
participant
MODBUS
participant
MODBUS
participant
SIMATIC S7-400
with 2x CP443-1
SIMATIC S7-400
with CP443-1
G_ST80_XX_00520
SIMATIC S7-300
SIMATIC ET 200S
tvki|zG
{jw
pG
l
ST80_2013_EN_Kap06.book Seite 24 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Customized software
S7 OpenModbusTCP
6/25
Siemens ST 80 / ST PC · 2013
Technical specifications
Ordering data
Order No. Order No.
2XV9 450-1MB00 2XV9 450-1MB02 2XV9 450-1MB11
Client/server functionality • / • • / • • / •
Function codes 1, 2, 3, 4, 5, 6, 15 and 16 1, 2, 3, 4, 5, 6, 15 and 16 1, 2, 3, 4, 5, 6, 15 and 16
Modbus address range 0 - 65535 0 - 65535 0 - 65535
Data volume
Read register 125 125 125
Write register 123 123 123
Read bits 2000 2000 2000
Write bits 1968 1968 1968
Capable of multi-instance • • •
Max. number
of parallel block calls • CPU-dependent
Client: No limits on block calls; max.
number of blocks simultaneously
active is limited by the CPU
(AG_SEND)
Server: Limited by the max. number
of AG_RECV calls of the CPU
• Unlimited number of block calls;
• Number of simultaneously estab-
lished connections is dependent on
the CPU
• CPU-dependent
Client: No limits on block calls; max.
number of blocks simultaneously
active is limited by the CPU
(AG_SEND)
Server: Limited by the max. number
of AG_RECV calls of the CPU
Connection
configuration Static connections over NetPro Dynamic connections over TCON and
TDISCON Static connections over NetPro
Communication AG_(L)SEND/
AG_(L)RECV TSEND/
TRCV AG_(L)SEND/
AG_(L)RECV
Work memory requirement
FB (Client/Server)
IDB
16 KB
approx. 1 KB
19 KB
approx. 1 KB
20 KB
approx. 1 KB
Can be used in CFC/PCS 7 • • •
Used with older CPs that do not
support AG_CNTRL Yes -No
Multiplexing of TCP connections CP-dependent -CP-dependent
Redundancy functions - - Single-sided or two-sided redun-
dancy is possible
Bit memories/timers can be used No No No
S7-OpenModbusTCP CP 2XV9450-1MB00
Tas k:
Software for coupling ModbusTCP
devices to SIMATIC S7 via a com-
munications processor (CP)
Type of delivery:
Function blocks for SIMATIC S7,
example projects, documentation
on CD
S7-OpenModbusTCP PN CPU 2XV9450-1MB02
Tas k:
Software for coupling ModbusTCP
devices to SIMATIC S7 via the inte-
grated PN interface
Type of delivery:
Function blocks for SIMATIC S7,
example projects, documentation
on CD
S7-OpenModbusTCP RED 2XV9450-1MB11
Task:
Software for coupling ModbusTCP
devices to SIMATIC S7 H stations
via 2 communications processors
(CPs)
Type of delivery:
Function blocks for SIMATIC S7,
example projects, documentation
on CD
ST80_2013_EN_Kap06.book Seite 25 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Examples of sector products
Examples of sector products
6/26 Siemens ST 80 / ST PC · 2013
6
Overview
SIMATIC HMI products are provided with additional features in
order to facilitate optimum use in specific sectors of industry.
Stainless steel front panels for the food, beverages and tobacco
industry are one such example. With the exception of their front
panels, the devices are identical to standard products in respect
of function and technology.
We can offer products for the following sectors:
Renewable energy
Automotive industry - HMI for factory automation
General machine construction
Food and beverages industry, pharmaceuticals
Oil & gas, chemicals industry and shipbuilding
Customized products for various industries are developed and
produced in association with a customized product agreement.
Examples:
Application area renewable energy:
- SIMATIC Rack PC with flexible expansion
- SIMATIC Box PC: 627/427 with QNX
Use in the automobile industry:
- HMI operator stations
- Front panel for Panel PC, 15" with arrow keys on the side
- Mobile Panel 277 10" Remote Operate
Application area mechanical equipment manufacture,
general:
- Touch and Key front panel 15" for Panel PC, resistant to
honing oil
- Flat Panels 10.4" for Panel PCs – Flat Panel SCD1900 portrait
Area of application food and beverages industry and
pharmaceuticals:
- Panels and Panel PCs with stainless steel front
- HMI panels as rear-mounting devices
- Flat Panels with stainless steel front
- HMI stainless steel operator stations
Area of application oil & gas, chemicals and shipbuilding:
- MP 377 15" Touch daylight readable
ST80_2013_EN_Kap06.book Seite 26 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Renewable energy
Renewable energy
6/27
Siemens ST 80 / ST PC · 2013
Overview
SIMATIC HMI products are provided with additional features in
order to facilitate use in specific sectors.
Photovoltaic systems are subject to hardly any mechanical
stress and therefore require little maintenance. This also requires
reliable and low-maintenance devices in the automation system.
With the wide operating temperature range at a high computing
power, with their various mounting styles, as well as options for
diagnostics and data backup, SIMATIC Panels and IPCs meet
these requirements.
Wind farms can be used in all climatic zones and also in poorly
accessible areas, e.g. offshore. The requirements regarding the
control systems are accordingly diverse, and complete freedom
from maintenance of the devices is required. The industrial PCs
of the 427 series can meet these requirements. Versions of the
Microbox treated by special paint processes can also be used
in salt-laden air.
ST80_2013_EN_Kap06.book Seite 27 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Renewable energy
Solar systems
6/28 Siemens ST 80 / ST PC · 2013
6
Overview
Solar systems
Compared to other power plants, photovoltaic systems are
subject to hardly any mechanical stress and therefore require
little maintenance. The same also applies for solar and solar-
thermal systems. This also reduces the maintenance overhead
on the devices. The SIMATIC Industrial PCs and Panels meet
these requirements through the targeted selection of high-
quality components and special production processes.
Benefits
SIMATIC Box PC family with mounting bracket for front mounting in
portrait format
Long service life
Extra long spare parts availability
Adapted computing power
High system availability
Individually adaptable
Application
All SIMATIC Panels and IPCs are developed for especially
demanding environments and also for long service life. Spare
parts availability for many years secures use in sound solar and
photovoltaic systems.
•Rugged:
Ambient temperatures of 0 °C to +55 °C offer high flexibility in
the choice of installation location. Use of a TEK is recom-
mended for increasing the temperature range
(see Chapter: Temperature Extension Kit).
Innovative and flexible:
- We meet the ever-increasing demand for more computing
power by using the current generation of processors from
Intel®. Based on the current chipsets, devices are available
with CeleronM, Core2Solo, Core2Duo and Core2Quad. This
makes power-saving applications (e.g. simple data acqui-
sition) just as possible as power-hungry applications (such
as the software PLC in real-time WinAC RTX) and server
systems.
- The SIMATIC IPCs fit into any control cabinet. Different
mounting methods enable a host of installation variants.
Optimized equipping of the Panels and IPCs for more system
availability is one of the simplest options for increasing produc-
tivity by means of reducing standstill times. Electromechanical
components often cause malfunctions in PCs. Since hard disks
and fans in the industrial PC usually operate continuously, they
are subject to an especially high rate of wear and tear. Software
options for diagnostics and data backup, such as SIMATIC IPC
DiagMonitor or SIMATIC IPC Image Creator, are particularly
effective here, in addition to the use of high-quality industrial
grade components.
ST80_2013_EN_Kap06.book Seite 28 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Renewable energy
Wind farms
6/29
Siemens ST 80 / ST PC · 2013
Overview
Wind farms
Wind farms can be used to produce electrical power in all
climatic zones, at sea, and in all types of terrain. The require-
ments regarding the control systems for wind turbines and wind
parks are as diverse as the installation locations.
These locations are increasingly difficult to reach. This means
the equipment must be completely maintenance-free. The
Industrial PCs of the 427 series can meet these requirements.
By selecting high-quality components and special production
procedures, all the SIMATIC IPCs and Panels can be used for
several years without requiring servicing.
Benefits
SIMATIC IPC427C with expansion frame
Suitable for special temperature requirements
Maintenance-free for offshore use
Can handle high mechanical load
High system availability
Individually adaptable
Application
All SIMATIC Panels and IPCs are developed for especially
demanding environments. The devices are optimally equipped
to deal with vibration in wind turbines: rugged enclosures,
special hard disk brackets, and interlocks are just a few
examples of standard features on SIMATIC devices.
•Rugged:
- The SIMATIC IPCs fit into any control cabinet. Different
mounting methods enable a host of installation variants.
Ambient temperatures of 0 °C to +55 °C are supported on
the IPC427C, with much higher temperatures in some appli-
cations. Use of a TEK is recommended for extreme temper-
atures (see Chapter: Temperature Extension Kit).
- Salt-laden atmospheres are hard on the devices. SIMATIC
Panels are also available in the IP65 type and are thus
eminently suitable for offshore use. Versions of the Microbox
427C also enable use in salt-laden atmospheres: this is
made possible by special paint processes that have been in
use for many years.
Innovative and flexible:
We meet the ever-increasing demand for more computing
power by using the current generation of processors from
Intel®. Based on current chipsets, devices with Celeron M,
Core2 Solo, Core2 Duo and Core2 Quad are available. This
makes power-saving applications (e.g. simple data acqui-
sition) just as possible as power-hungry applications (such as
the software PLC in real-time WinAC RTX) and server systems.
Optimized equipping of the IPC and the Panel for more system
availability is one of the simplest options for increasing produc-
tivity by means of reducing standstill times. Electromechanical
components often cause malfunctions in PCs. Since hard disks
and fans in the industrial PC usually operate continuously, they
are subject to an especially high rate of wear and tear. Software
options for diagnostics and data backup, such as SIMATIC IPC
DiagMonitor or SIMATIC IPC Image Creator, are particularly
effective here, in addition to the use of high-quality industrial
grade components.
ST80_2013_EN_Kap06.book Seite 29 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Automotive industry
HMI operator stations for the automobile industry
6/30 Siemens ST 80 / ST PC · 2013
6
Overview
Operations computer: Unit operator panel and protective guard control
box (PGCB)
The fully-equipped and wired turnkey solutions in a variety of
designs are ideal for the requirements of the automotive industry.
Benefits
Modern design combined with outstanding functionality
Increased heat dissipation thanks to ribbed aluminum profile
and backpanel heat sink
Easy access to controls thanks to hinged front frame or hinged
backpanel
Modular system for precise customization and tailoring to
Panel or Panel PC
High-quality aluminum press-drawn section with clean
surface finish
Colors to complement design, also possible in customized
RAL colors
Rugged and maintenance-friendly device design
Very high EMC
Distributed configuration for large machines and distributed
installations
Optimized high-speed operator control thanks to:
- Reduced number of operator controls
- Optimum control element layout
- 24 V DC hardware
- Direct keys or high-speed PROFIBUS communication for
direct keys
Use of high-capacity mass storage for large software applica-
tions
Silicone-free device configuration
Chemically-resistant surfaces (resistant to lubricants and
fillers, oils, etc., in particular)
Welding sputter-resistant surface
Project-specific software ready installed
Application
In automotive industry, the fault-free operation of production
facilities is of paramount importance. The requirements of indus-
trial control enclosures in respect of impermeability to dust and
water, as well as those in respect of the management of the
internal heat balance are therefore very high. In addition to the
HMI IPC477C and HMI IPC577C, the HMI IPC677C and Flat
Panels are also suitable for use as operator PCs in the
automotive industry.
Design
The modular design with a variety of aluminum frame and
expansion profiles can support all required device combina-
tions. A variety of operator stations appear in the overview:
- Modular aluminum control enclosure system for the combi-
nation of multiple HMI Panels, Panel PCs, and Simatic S7
PLCs
- Modular aluminum control enclosure system
for the combination of multiple HMI Panels
- Modular aluminum control enclosure system
for the installation of an HMI Panel or Panel PC
(see "Overview" figure bottom left)
Can be accessed via hinged front frame or hinged backpanel
Integrated support arm elements at the top and bottom for the
direct attachment of support arm couplings
Integrated handle attachments facilitate handling and
underline the design image
Certifications/Approvals
•IP65
NEMA 4/EEMAC Type 12
• cULus
•CE
ST80_2013_EN_Kap06.book Seite 30 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Automotive industry
HMI operator stations for the automobile industry
6/31
Siemens ST 80 / ST PC · 2013
Technical specifications
More information
Quotation preparation
Product specification according to customer requirements.
Quotation preparation by SIMATIC HMI specialists,
specification of:
Non-recurring costs
Prototype costs
Standard unit prices
General conditions (product agreement)
There is a minimum annual quantity/purchase quantity
(minimum quantity per type: 20), which is agreed with the
customer for the project.
Customized products can only be ordered in conjunction
with a product agreement.
A customer-specific order number is allocated during the
product agreement process.
SIMATIC contacts in your area
http://www.siemens.com/automation/partners
Examples from the automotive industry
Type HMI operator control unit Operator PC unit operator panel + PLC
Components
Computing unit SIMATIC HMI IPC677C PC Box based on SIMATIC HMI IPC677C
• Core i7, 2.53 GHz, 4 GB RAM
250 GB HD,
PROFINET + 2 x Ethernet interfaces 10/100 Mbit
• Europe default 230 V
• Core i7, 2.53 GHz, 4 GB RAM
250 GB HD,
• Without MPI/PROFIBUS +
2 x Ethernet interface 10/100 Mbit
• Europe default 230 V
Front panel SIMATIC HMI IPC677C 15" Touch,
15" XGA 1024x768 resolution Customized front with 2x6 control keys,
15“ XGA 1024x768 resolution
Additional components • PP17-I PROFIsafe
• PP17-II
S7-400 configuration
Additional components
Operator panel enclosure CC-4000, mounted on stand VIP 6000 (upper part)
IW 6900 (lower part)
Dimensions 578 x 764 x 183 mm 630 x 1870 x 636 mm
Operator panel with slide-in label
Keyboard Sasse stainless steel keyboard IP65 Sasse stainless steel keyboard IP65
Mouse Track-Ball integrated in the keyboard Optical mouse
Elements 3 x 3SB3 elements with labeling plates,
1 x Emergency Off,
1x machine circuit-breaker,
signal light processing possible
2 x 4 operator controls,
1 x Emergency Stop
Locking • E1-locking for enclosure lock
E7 key-operated switch Customized enclosure lock
Mounting Installation in operator panel enclosure
with electrical wiring Installation in operator panel enclosure
with electrical wiring
Ventilation – –
Ter minals Use of 3-wire terminals Use of Wago terminals
Core identification Yes Yes
Base profile • Icotec
• RJ45 Ethernet port • Icotec
• RJ45 Ethernet port
Software: • Windows 7, MUI
WinCC V7.x
• SIMATIC STEP 7 Prof V5.x
• Windows 7, MUI
SIMATIC Softnet S7 for IE V 6.x
SIMATIC STEP 7 V 5.x
SIMATIC S7-Graph V 5.x
SIMATIC DistributedSafety V 5.x
InTouch Runtime V 9.x
Type Protective guard control box
(PGCB)
Components SIMATIC HMI KP8F
• SIMATIC ET200S
• SCALANCE X202 – 2P IRT
Ethernet switch
Additional components
Operator panel enclosure AE housing
Dimensions 300 x 300 x 155 mm
Elements • 8 short-stroke keys
• 1 x emergency stop
3 x Siemens key switches
1 x signaling column
Locking Customized enclosure lock
Mounting Installation in operator panel
enclosure with electrical wiring
Core identification Yes
ST80_2013_EN_Kap06.book Seite 31 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Automotive industry
Front panel 15" with motion keys at side
6/32 Siemens ST 80 / ST PC · 2013
6
Overview
Front panel 15" with function keys at side
for Panel PC in the automotive industry
The front panel 15.1" with arrow keys at side is designed as a
front unit for Panel PC. The arrow keys at the side allow intuitive
and direct activation of movements in the plant. The display is a
pure display unit, alphanumeric characters are entered using an
external keyboard and external pointing device.
Benefits
Display unit with additional function keys for efficient and
direct activation of motions
Display surface resistant to welding beads
24 V DC function keys for wiring to digital inputs of controller
Non-interchangeable terminals
Application
Application example: Operations computer in the automotive industry
The front panel for Panel PCs with function keys at the side is
designed for HMI operations in the automotive industry, e.g. as
a display for control computers.
The front unit as the display unit with function keys at the side is
always used if comprehensive inputs are necessary using an
external keyboard and pointing device, but where efficient
control of movements should be additionally possible using the
function keys assigned to the graphics and directly to the PLC.
Design
2 x 6 function keys (24 V DC) on left and right of display
Function keys connectable using non-interchangeable
terminals, e.g. using vacant inputs of a Push Button Panel to
the control
Display surface resistant to welding beads
USB interface at the front
External dimensions and mounting cutout as for corre-
sponding standard product
IP65 degree of protection at the front
Technical specifications
Modification possibilities
Customized design
Modification of front design
More information
Quotation preparation
Product specification according to customer requirements.
Quotation preparation by SIMATIC HMI specialists,
specification of:
Non-recurring costs
Prototype costs
Standard unit prices
General conditions (product agreement)
There is a minimum annual quantity/purchase quantity
(minimum quantity per type: 20), which is agreed with the
customer for the project.
Customized products can only be ordered in conjunction
with a product agreement.
A customer-specific order number is allocated during the
product agreement process.
SIMATIC contacts in your area
http://www.siemens.com/automation/partners
Type Front panel 15"
with lateral function keys
Display 15.1" TFT
Resolution (pixels) 1024 x 768 pixels
General features As for 15.1" front panel
for HMI IPC677C
Special features
Interfaces USB interface at the front
Connectable to Panel PC HMI IPC477C, HMI IPC677C,
compact and distributed design
Number of keys 2 x 6 function keys (24 V DC)
on left and right of display,
wired to terminals
ST80_2013_EN_Kap06.book Seite 32 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Automotive industry
Mobile Panel 277 10" Remote Operate
6/33
Siemens ST 80 / ST PC · 2013
Overview
Front view
For high-contrast and clearly readable display of already
configured SIMATIC WinCC process pictures of a stationary
operator panel (e.g. with PC 677) without further configuring
and adaptation overhead
Server and client optimized for the following resolutions:
- Remote Operate Server with 1024 x 768 pixels
- Remote Operate Client with 800 x 600 pixels.
• Features
- High-resolution display 10" SVGA
- Integral acknowledgment and stop button
(safety category 3 in accordance with EN 954-1)
- Rugged and double-panel enclosure
(drop height 1 m, complete IP65 degree of protection)
- Thin Client concept:
Communication with the higher-level operator station using
Remote Operate software and PROFINET
Application
RO Client 800 x 600 pixels and RO Server 1024 x 768 pixels
The SIMATIC Mobile Panel 277 10" Remote Operate (RO) from
Siemens bridges the gap between flexible use through porta-
bility and ease of handling, and the benefits of a thin client
concept.
Existing WinCC configurations of a Panel PC 677 15" can be
represented with functional compatibility. Reliable data transfer
and short response times are guaranteed here. Operator input
using the touch screen is intuitive. The optional device holder
enables secure storage or stationary operation of the Mobile
Panel.
Design
Rear view
Side view
User-friendliness and ergonomic use were consistent design
considerations. With its low weight and compact design, the
Mobile Panel sits comfortably in the hand.
The Mobile Panels are extremely impact-resistant thanks to the
double-panel design and the rounded enclosure shape. The
STOP button is protected by a "collar" against unintentional use
and against damage when dropped. Harsh industrial environ-
ments present no problems to the SIMATIC Mobile Panels with
their dust and spray-water-protected enclosures in degree of
protection IP65.
The Mobile Panel is simply connected wherever it is needed in
the plant. The rugged connection box with degree of protection
IP65 can be installed anywhere. It ensures fault-free connection
and disconnection during normal operation and thus enables
the operator-control locations to be easily and safely changed
when several connection points are available in a plant.
The cable is up to 25 meters in length and handles power
supply, transfer of the STOP and acknowledgment button
signals, and also data communication.
The device has no rotating media.
ST80_2013_EN_Kap06.book Seite 33 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Automotive industry
Mobile Panel 277 10" Remote Operate
6/34 Siemens ST 80 / ST PC · 2013
6
Mode of operation
All applications are run on the the Remote Operate Server,
which in turn handles any control connection to the production
process. The user now decides which applications will be
operated and monitored from the Mobile Panel. The plant
operator hardly notices that he or she is now working on the main
operator station and no longer locally.
The device does not process the data locally, but instead
accesses the data of up to ten selectable main operator stations
with the help of the pre-installed Remote Operate Client
software.
These main operator stations are, in turn, equipped with the
Remote Operate Server software. All stations are connected
via Industrial Ethernet.
The Mobile Panel is thus optimized exclusively on the visual-
ization and management of the different stationary operator
stations.
Communication with the higher-level operator station takes
place via the Remote Operate software and is enabled via
PROFINET.
Function
Automatic restart after switching on and display of the server
selection list (up to 4 hierarchical levels and up to 10 servers)
Password protection
Automatic Reconnect of client
Operation authorization indication (traffic light) on the server
and client
Sophisticated safety concept
The Mobile Panel has an acknowledgement button (in accor-
dance with EN 60204-1) with three switching steps. This can be
adjusted to an ergonomic position for both left-handed users
and right-handed users simply by turning.
The STOP pushbutton (acc. to EN 60204-1) can be looped into
the EMERGENCY OFF circuit of a machine and positively
latches when pressed. It is distinguished from an EMERGENCY-
OFF button by its gray color. This ensures that it cannot be
mistaken for the EMERGENCY-OFF equipment.
The STOP and acknowledgment buttons are implemented
as double circuits in accordance with Safety Category 3 to
EN 954-1.
Technical specifications
Ordering data
Order No.
Type Mobile Panel 277 10"
Remote Operate
Display 10" touch screen SVGA with
800x600 pixels, TFT display with
65,536 colors
Operation Touch screen with captive stylus
and stylus holder, three-level
acknowledgment button (dead-
man's switch) integrated into the
handle, stop button, function keys,
key-operated switches and backlit
pushbuttons as option. Suitable for
left and right-handed operation
Interfaces Hardwired connection line to con-
nection box Plus for PROFINET/
Ethernet and power supply
(e.g. Mobile Panel 277 PN)
Software Remote Operate Client software
(Thin Client) on Windows CE 5.0,
function-compatible representation
of existing WinCC configurations/
software applications of an existing
server, e.g. PC677
Ambient conditions Full IP65 degree of protection,
ambient operating temperature 0°C
to 40°C, drop height to 1.0 m
Certification CE, cULus, C-Tick,
EMC compliance, prototype test
(BG/BIA or SIBE Switzerland)
In the accessories pack CD-ROM, operating instructions,
programming manual for Remote
Operate Software
Options Membrane function keys, access
control (key-operated switch),
buttons, handwheel
Weight 2.3 kg
Type PN Plus connection box
Interfaces 2 x Ethernet with 10/100 Mbit/s,
integrated switch
Expansion for operator-process com-
munication Reconnection during operation with-
out interrupting the emergency stop
circuit, monitoring of the STOP but-
ton, location recognition (through
hardware)
Mobile Panel 277 10"
Remote Operate 6AV6645-7AB10-0AS0
Configuration on request
Connection box PN Plus 6AV6671-5AE11-0AX0
Connecting cable
•5 m 6XV1440-4BH50
• 10 m 6XV1440-4BN10
• 25 m 6XV1440-4BN25
ST80_2013_EN_Kap06.book Seite 34 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Automotive industry
Mobile Panel 277 10" Remote Operate
6/35
Siemens ST 80 / ST PC · 2013
More information
Customer-specific modifications
Individual company logo instead of the Siemens logo and
changing the type designation
Changing the keyboard colors, labeling, symbols and
background color
Possible options: Membrane function keys, access control,
pushbuttons and handwheel
Quotation preparation
SIMATIC HMI specialists define the product modifications
precisely in accordance with customer requirements.
This is followed by drafting of a quote by SIMATIC HMI
specialists, determining the following:
Non-recurring costs
Prototype costs
Standard unit prices
and the marginal conditions in the form of a product
agreement (e.g. minimum quantity).
The defined device can be easily ordered using this product
agreement and a customized order number. Device fronts are to
be stored and provided by the customer upon delivery
completion.
ST80_2013_EN_Kap06.book Seite 35 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
General machine construction
Front panel 15" Touch and Key for Panel PCs,
resistant to honing oil
6/36 Siemens ST 80 / ST PC · 2013
6
Overview
The Front Panel Touch and Key is designed as a front unit for
Panel PCs. The combination of Touch and Key operation as well
as the resistance to honing oil are characteristics of this product.
Complete lamination of the decoration foil over the touch area of
the display increases the resistance against contamination and
welding beads, and the absence of edges and joints facilitates
cleaning. Openings and cutouts in the front have been
completely omitted in favor of a homogenous surface which can
also be used in the environment of honing oil and similar cooling
agents and lubricants.
Clear operation is achieved using the Touch pen which is
delivered as standard and can be stored in a front holder. Dirty
or oily hands are therefore not an argument against using a
Touch screen. The pen has an ergonomic shape, is optimized for
operations when wearing gloves, and is linked to the front using
an elastic helix cable. Its "parking position" in the special
stainless steel holder on the front means that it is always readily
accessible.
Benefits
Combined Touch + Key operation for increased inefficiency
Touch pen operation avoids contamination of the display area
Ergonomically shaped touch pen which cannot be lost
Simple cleaning
Resistant to coolants and lubricants
Application
The front panel for Panel PCs with touch screen and membrane
keyboard has been designed for operator control and
monitoring at machine level for machine construction applica-
tions, where honing oil and lubricants are used.
The touch and key front is always used if efficient operation of
the machine is associated with the following requirements:
Intuitive operation using graphic representation on display
Specific command inputs using fixed command inputs
Effective inputs in forms using the integrated numeric and
alphanumeric keyboard
Also in applications with increased environmental influences
such as dirt and oil. The homogenous foil surface without joints
or edges permits easy cleaning, and is resistant to coolants and
lubricants.
Application examples
Printing machines
Drilling, milling, honing machines
Brake test stands
Injection molding machines
Building management
Warehouse systems
Automotive industry
Design
External dimensions and mounting cutout as for corre-
sponding standard product
Degree of protection IP65 at the front
ST80_2013_EN_Kap06.book Seite 36 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
General machine construction
Front panel 15" Touch and Key for Panel PCs,
resistant to honing oil
6/37
Siemens ST 80 / ST PC · 2013
Technical specifications
More information
Quotation preparation
Product specification according to customer requirements.
Quotation preparation by SIMATIC HMI specialists,
specification of:
Non-recurring costs
Prototype costs
Standard unit prices
General conditions (product agreement)
There is a minimum annual quantity/purchase quantity (minimum
quantity per type: 20), which is agreed with the customer for the
project.
Customized products can only be ordered in conjunction with a
product agreement.
A customer-specific Order No. is allocated during the product
agreement process.
http://www.siemens.com/automation/partners
Type Front panel 15" Touch + Key,
resistant to honing oil
Display 15.1" TFT Touch
Resolution (pixels) 1024 x 768 pixels
General features As front panel 15.1" Touch
for Panel PC 677
Special features
Interfaces Without front-sided USB interface
Connectable to Panel PC PC 477, PC 677 compact
and distributed design
Number of keys 58 system keys and
alphanumeric keys
20 function keys with LED
Resistance Tested with:
Castrol Honilo 981 honing oil
ST80_2013_EN_Kap06.book Seite 37 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
General machine construction
Flat Panels, 10.4" for Panel PC
6/38 Siemens ST 80 / ST PC · 2013
6
Overview
Ideal for machine-level human machine interfacing
Especially suitable for use in machines with restricted instal-
lation space
Can be modified in design and front mechanical components
(e.g. stainless steel front for food and beverages industry)
Distance between the Flat Panel and PC max. 30 m
Functions correspond to the standard Flat Panels
Available with and without touch operation
VGA and SVGA resolution
Application
The Flat Panel 10.4" TFT Touch has been designed as display
and operator control unit for industrial PCs (e.g. SIMATIC
Microbox 427C) and Panel PCs (e.g. PC 677C) and can be
separated from the computing unit by up to 30 m.
They supplement the SIMATIC standard products and are
suitable for machine-level human machine interfacing when PC
functionality is required but little space is available for installing
a display. VGA and SVGA resolution also in a secondary display,
e.g. Panel PC 677C.
Technical specifications
Ordering data
Order No.
More information
Customized modification options
Customized design
Modification of front design, e.g. stainless steel front
Flat Panel 10.4”
Resolution (pixels) 800 x 600 pixels
Input unit Analog-resistive touch screen
MTBF (at 25 °C) 50 000 h
Power supply 24 V DC, RoHS
Front dimensions
(L x W x D in mm) 335 x 275 x 75
Installation dimensions
(L x W in mm) 310 x 248
Certified in accordance with
Can be connected to
Approx. weight in kg 0.80
Flat Panel 10" Touch 6AV7461-7TA00-0AA1
SIMATIC Flat Panel 10.4" TFT
with analog-resistive Touch Panel,
resolution 800 x 600 pixels, 24 V DC
power supply, VGA, DVI-D interface,
incl. VGA cable 1.8 m
ST80_2013_EN_Kap06.book Seite 38 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Food and beverages industry/pharmaceuticals
Introduction
6/39
Siemens ST 80 / ST PC · 2013
Overview
Hygiene areas in food and beverage production, pharmaceu-
ticals or fine chemicals all share one requirement: The devices
and equipment must be easy to clean. The relevant directives,
standards and legislative requirements must be observed, e.g.
EHEDG, FDA, DIN EN 1672-2 (Hygienic Design), GMP, LMHV,
LMBG.
However, optimization and variation in the device hardware are
also perfectly possible:
Degree of protection
• Ruggedness
Temperature resistance
Design and installation versions
Suitable for clean rooms
Certification in accordance with ATEX
The aim is to find the cost-optimized solution for the specific
application case.
The overview below shows different features depending on the
applications areas, from packaging to the wet area in
processing.
The product examples described on the following pages cover
a wide range of the most important requirements.
Benefits
Simpler cleaning thanks to resistant and rugged stainless
steel front with smooth surface, and minimal grooves and
gaps
High degree of protection IP66K (TP 177B and MP 277
additionally IP66K) on the front for increased sealing
properties and ruggedness
Food-standard sealing material and shatter protection for the
display to prevent contamination of the foodstuffs
Optimized frame design almost flush with the control cabinet
so that liquids can run off
Device front developed on the basis of DIN EN 1672-2
Decorative membrane tested against chemicals in accor-
dance with DIN 42115, Part 2
1)
Food-standard flat seal in accordance with
FDA 21 CFR 177.2006
Rear tensioning frame (included in scope of supply) for even
application pressure of the seal
External dimensions and mounting cutout as for corre-
sponding standard product
1)
Special resistance requirements must be examined separately.
High degree of protection for humid environments
With low installation depth and rugged front, the SIMATIC HMI
Standard Panels are eminently suitable for industrial and
machine-level use.
The Panels with stainless steel front are also even better
equipped to meet the high requirements presented by the food
and beverage production environment. IP66K degree of
protection protects against water even with a jet strength of
100 l/min at 10 bar from a distance of 2.5 m to 3 m. The
optimized frame profile and almost flush-mounting of the device
on the control cabinet allow liquids to run off.
Installation of the operator panels in a stainless steel control
cabinet as ready-to-use units is optionally available as a
customized version.
Applications
Features Hygienic packaging Pharmaceuticals,
fine chemicals Food and beverages,
bottle cleaning,
bottle filling, laboratories
Abattoirs,
meat processing
Stainless steel front partially xxx
Stainless steel control boxes xxxx
Stainless steel fully enclosed xxxx
Simple to clean xxxx
No grooves and gaps,
no projections partially partially membrane-covered
protective edge not
always accepted
-
Increased tightness - - x x
Mechanical ruggedness,
no membrane front --partially x
Suitable for high-pressure cleaning
(IP69K) ---partially
ATEX Ex Zone 2/22 xxpartially -
ST80_2013_EN_Kap06.book Seite 39 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Food and beverages industry/pharmaceuticals
Introduction
6/40 Siemens ST 80 / ST PC · 2013
Benefits (continued)
6
Certificates, listings and appraisals
SIMATIC HMI products with stainless steel front, and the
stainless steel operator panel, were subjected to some or all of
the tests below and are listed or appraised in accordance with:
High degree or protection IP66K, NEMA Type 4, 4x, 12
CE-compliant, cULus-listed
LGA mark "Hygiene tested"
(Approval document No. 5664018)
Expert appraisal of the Munich University of Technology,
Research Center Weihenstephan, in accordance with EHEDG
recommendation (Report No.126/01.03.2007)
Clean room qualification by IPA Fraunhofer Institute
(test report: Examination of the clean room suitability and
ESD characteristics of Panel PCs from Siemens AG,
Report No. SI 0810-450 of October 2008)
Qualification for clean rooms
High-quality products such as semiconductors, medicines,
food & beverages, and nanotechnology products are subject to
special demands with regard to contamination with particles or
bacteria.
Increased requirements for protection of the products and
processes can only be met by production in clean rooms with
suitable equipment under controlled conditions.
Clean rooms are classified according to particle quantities and
sizes per m
3
of room air and time unit. Clean room classes in
accordance with ISO 14644-1 (ISO 1 to 9) have been introduced
in pharmaceuticals, for example, in accordance with EG-GMP,
Annex 1 (Classes A to F), and in semiconductor production.
Example:
A person in normal clothing emits approximately
80,000 particles >= 0.5 mm per second
(in clean room clothing, this can be reduced to
approximately 700 particles/s >= 0.5 mm).
Requirements regarding equipment in clean rooms include
the following:
Surfaces that are easy to clean and disinfect
As few adhesives as possible, e.g. electrostatic
No emitting surfaces
Shape favorable to air circulation, no air eddies
Dense, as few hollow or dead spaces as possible
Smooth, as few grooves and gaps as possible
The SIMATIC HMI products with stainless steel front and the
stainless steel operator panel have been designed for these
requirements.
The stainless steel operator stations with Panel PC 677B
15" Touch INOX and MP 377 15" Touch INOX have been tested
by the Fraunhofer Institute and qualified for "obvious suitability
for clean rooms of ISO Class 1 in accordance with
DIN EN ISO 14644-1".
Application
Quality and hygiene are decisive competitive features in the
production of food and beverages. In addition, higher volumes
have to be produced in shorter times and with rising quality
demands.
Objects and equipment that come into contact with food and
beverages must be
such that they are clean and can be maintained and, if
necessary, disinfected, and have no adverse effect on the
food and beverages
installed in such a way that the immediate environment can be
cleaned appropriately.
Objects and equipment must be clean and well maintained
(extract from the German food and beverages hygiene legis-
lation). This requires not only the innovative know-how of
engineering offices, mechanical equipment manufacturers and
plant builders, but also modern, powerful human machine
interface systems whose hardware and software are adapted to
the special requirements.
The SIMATIC Panels and Panel PCs with touch screens and
stainless steel fronts have been designed for use in the food,
beverages and tobacco industry and for operator control and
monitoring close to food processing machines. For this reason,
the devices with stainless steel front have been developed in
compliance with DIN EN 1672-2 "Food processing machinery –
Safety and Hygiene Requirements".
Simpler cleaning and disinfecting
The high quality requirements in the food and beverages
industry require a high standard of the food processing
machinery. There are many relevant regulations, directives,
ordinances, standards and laws. Essential here is that all
equipment and components must be easy to clean and disinfect
so that cross-contamination of the foodstuffs can be avoided.
The Panels with stainless steel front have a 240 grit hairline
finish, so they are suitably smooth. The membrane covering the
display cutout is tested with regard to its resistance to
chemicals, has minimal grooves and gaps in which micro-
organisms could settle, and also provides shatter protection for
the display.
ST80_2013_EN_Kap06.book Seite 40 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Food and beverages industry/pharmaceuticals
Panels and Panel PCs with stainless steel front
6/41
Siemens ST 80 / ST PC · 2013
Overview
TP 177B color PN/DP, MP 277 10" Touch, MP 377 15" Touch
and Panel PC 677B 15"
The SIMATIC Panels with touch screens and stainless steel
fronts have been designed for use in the food, beverages and
tobacco industry for operator control and monitoring close to
food processing machines. They have been developed in
compliance with DIN EN 1672-2 "Food processing machines –
Safety and Hygiene Requirements".
Simple cleaning and disinfecting
- Stainless steel surface with 240 grade hairline finish
- Membrane tested for resistance to chemicals
- Minimal number of grooves and joints
- Optimized frame profile so that liquids can run off
Display shattering protection
Degree of protection IP66K
Design
External dimensions and mounting cutout as for corre-
sponding standard product
Optimized frame profile with a slight projection to the cabinet
IP66K degree of protection at the front
Surface ground with 240 grain abrasive
Minimal number of grooves and joints
Decorative film tested for resistance to chemicals
Display splash protection
Food-standard seals
Rear tensioning frame for even application pressure of the
seal
Technical specifications
Multi Panels
MP 277 10" Touch INOX MP 377 15" Touch INOX
General features
Power supply 24 V DC 24 V DC
Display 10.4" color TFT Touch 15.1" TFT Touch
Resolution (pixels) 640 x 480 1024 x 768
MTBF of backlighting (at 25 °C) about 50 000 hours LED backlighting about 50 000 hours CCFL backlighting
Front
Material Stainless steel 1.4301, polyester-based membrane
Surface Hairline finish, 240 grit abrasive grain
Device seal EPDM flat seal
Special features
Ambient conditions
Degree of protection on the front: IP66K, NEMA 4, 4x and 12; on the rear: IP20
Ambient temperature during operation 0 ... 50 °C
Relative humidity max. 85% (no condensation)
Transport/storage temperature -20 °C to +60 °C
Approvals FM Class 1 Div 2, cULus, CE, C-Tick, ATEX Zone 2/22
Sector Food & beverages, pharmaceuticals Food & beverages, pharmaceuticals
HMI software
(to be obtained separately)
HMI engineering software WinCC flexible 2005 Standard and higher WinCC flexible 2007 Standard and higher
Dimensions
External dimensions
(W x H x D in mm) 325 x 263 400 x 310
Installation cutout (W x H x D in mm) 310 x 248 368 x 290
Special features Clamping frame Clamping frame
Weight Approx. 4.2 kg Approx. 6.2 kg
ST80_2013_EN_Kap06.book Seite 41 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Food and beverages industry/pharmaceuticals
Panels and Panel PCs with stainless steel front
6/42 Siemens ST 80 / ST PC · 2013
Technical specifications (continued)
6
Panel PC Panels
Panel PC 677B 15" Touch INOX TP 177B PN/DP INOX
General features
Power supply 100/230 V AC (autorange), 50/60 Hz or 24 V DC 24 V DC
Display 15.1" TFT Touch 5.7" color STN Touch (256 colors)
Resolution (pixels) 1024 x 768 320 x 240
MTBF of backlighting (at 25 °C) about 50,000 hours CCFL backlighting
Special features Without front USB interface 1 x emergency-off, 3 x short-stroke membrane keys with
LED on front, wired to terminal
Front
Material Stainless steel 1.4301, polyester-based membrane
Surface Hairline finish, 240 grit abrasive grain
Device seal EPDM flat seal
Special features on the front: IP66K, NEMA 4, 4x and 12; on the rear: IP20 Decorative membrane drawn across the display
Ambient conditions
Degree of protection on the front: IP66K, NEMA 4, 4x and 12; on the rear: IP20 on the front: IP66K, NEMA 4, 4x and 12; on the rear: IP20
Ambient temperature during operation 0 ... 50 °C 0 ... 50 °C
Relative humidity max. 85% (no condensation)
Transport/storage temperature -20 °C to +60 °C
Approvals CE, cULus FM Class 1 Div 2, cULus, CE, C-Tick, ATEX Zone 2/22
Sector Food & beverages, pharmaceuticals Food & beverages, pharmaceuticals
HMI software
(to be obtained separately)
HMI engineering software WinCC flexible Advanced and higher WinCC flexible 2005 Compact and higher
HMI Runtime software WinCC flexible RT
Dimensions
External dimensions
(W x H x D in mm) 483 x 310 212 x 156
Installation cutout (W x H x D in mm) 450 x 296 198 x 142
Special features Clamping frame Clamping frame
Can be connected to SIMATIC PC On Panel PCs as well as other SIMATIC Rack and Box
PCs
Weight Approx. 15 kg Approx. 1.5 kg
ST80_2013_EN_Kap06.book Seite 42 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Food and beverages industry/pharmaceuticals
Panels and Panel PCs with stainless steel front
6/43
Siemens ST 80 / ST PC · 2013
Ordering data
Order No.
More information
Customized modification options
Customized design
- Use of the company name instead of the Siemens logo and
modification of the type designation
- Changing the background color
Customer-specific hardware modifications such as the design
and dimensions of the front plate, selection of the display,
memory capacity, drives, options
Customer-specific Panel PC configuration as a rugged
embedded hardware and software system, without hard disk
and with tailor-made software
Customer-specific software suite with choice of Windows
operating systems
Customer-specific Panel PCs with software suite with choice
of Windows operating systems
Protection against condensation and corrosive gases
(for selected panels)
Device mounted in a stainless steel cabinet as a ready-to-
install and ready-to-connect terminal which is ergonomic,
functional, with high degree of protection as well as tested
heat dissipation (e.g. with complete degree of protection
IP66K)
Drafting a quotation
SIMATIC HMI specialists define the product modifications
precisely in accordance with customer requirements.
This is followed by drafting a quotation with:
Non-recurring costs
Prototype costs
Standard unit prices
and the marginal conditions in the form of a product
agreement (e.g. minimum quantity).
The defined device can then be easily ordered using this
product agreement and a customized Order No.
TP 177B color PN/DP INOX 6AV6642-8BA10-0AA0
with stainless steel front,
otherwise corresponding to
6AV6642-0BA01-1AX0
MP 277 10" Touch INOX 6AV6643-0ED01-2AX0
with stainless steel front and LED
backlight, otherwise corresponding
to 6AV6643-0CD01-1AX1
MP 377 15" Touch 6AV6644-0CB01-2AX0
with stainless steel front and LED
backlight; otherwise corresponding
to 6AV6644-0AB01-2AX0
Panel PC 677B 15" 6AV7872-2…
with stainless steel front, otherwise
corresponding to Panel PC 677B
Configurator 6AV6643-0CD01-1AX1
ST80_2013_EN_Kap06.book Seite 43 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Food and beverages industry/pharmaceuticals
HMI Panels as rear-mounted devices
6/44 Siemens ST 80 / ST PC · 2013
6
Overview
MP 377 12" Touch, rear-mounting
MP 277 8" Touch vertical, rear-mounting
MP 377 12" Touch, rear-mounting,
MP 277 8" Touch vertical, rear-mounting
The solution for installing HMI devices without "corners and
edges" on the front. The devices are installed in the control
cabinet enclosure from the rear and are flush with the control
cabinet sheet metal at the front. They are therefore known as
"rear-mounting devices".
Benefits
Front surface flush with the control box
Simple to clean
No dirt-collecting edges and deposits
Front membrane resistant to the usual cleaning agents and
disinfectants
Can be replaced with front-mounting device of the same type
for service purposes (MP 377 12" Touch rear-mounting only)
Design
The front frame is modified customer-specifically on the
"rear-mounting devices":
The surface with the display viewing area covered with
decorative membrane, and the marginal area around the display
necessary for touch operation must be flush with the control
cabinet sheet metal at the front. For this purpose, the front frame
with the device seal and the cutouts for the holding bolts are set
back from the visible surface by the thickness of the control
cabinet sheet metal. The enclosure must have a suitable number
of stud bolts available. The all-round device seal thus enables a
high degree of protection: IP65.
The installation cutout can be dimensioned in such a way that
the rear-mounting device can be replaced with the same type of
front-mounting device for service purposes.
The decorative membrane is also drawn across the visible area
of the display on the rear-mounting devices, so there is no cutout
with adhesive edge above the display. The decorative
membrane is smooth.
For sensitive applications where the gap dimension of the
control cabinet cutout has too great a tolerance, there is the
option of covering the entire surface including the gap with a
transparent and replaceable membrane.
ST80_2013_EN_Kap06.book Seite 44 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Food and beverages industry/pharmaceuticals
HMI Panels as rear-mounted devices
6/45
Siemens ST 80 / ST PC · 2013
Technical specifications
Ordering data
Order No.
More information
Customized modification options
Customized rear-mounting versions can also be implemented:
Customized operator controls possible on the front,
e.g. membrane keys, emergency-off
Adaptation to the design of the customized enclosure
Customized design (logo and color scheme) on the front
membrane
Portrait mode of the display
Increased resistance to shock and machine vibration
Quotation preparation
SIMATIC HMI specialists define the product modifications
precisely in accordance with customer requirements.
This is followed by drafting of a quote with:
Non-recurring costs
Prototype costs
Standard unit prices
and the marginal conditions in the form of a product
agreement (e.g. minimum quantity).
The defined device can then be easily ordered using this
product agreement and a customized order number.
MP 277 8" Touch vertical, rear-mounting MP 377 12" Touch, rear-mounting
General features
Power supply 24 V DC 24 V DC
Display 7.5" TFT Touch 12.1" TFT Touch
Resolution (pixels) 480 x 640 (portrait) 800 x 600
MTBF of backlighting (at 25 °C) about 50,000 hours CCFL backlighting
Special features 1 x emergency-off, 3 x short-stroke membrane keys with LED on front, wired to terminal
Front
Material Aluminum under polyester-based membrane
Surface Hairline finish, 240 grit abrasive grain
Device seal On the enclosure, customized On the front
Special features Decorative membrane drawn across display
Ambient conditions
Degree of protection IP65 at front; IP20 at rear
Ambient temperature
during operation 0 ... 50 °C
Relative humidity max. 85% (no condensation)
Transport/storage temperature -20 °C to +60 °C
Approvals CE CE, cULus
Sector Food & beverages, packaging systems, pharmaceuticals
HMI software
(to be obtained separately)
HMI engineering software From WinCC flexible 2007
Standard with add-on for portrait format WinCC flexible 2007 Standard and higher
Dimensions
External dimensions
(W x H x D in mm) 229 x 318 As installation cut-out
Installation cutout (W x H x D in mm) 233 x 322 x 67 Compatible with standard device
Special features Rear-mounting panel in portrait format Rear-mounting panel; panel cutout as on standard device
Weight Approx. 2.7 kg Approx. 5.5 kg
MP 377 12" Touch, rear-mounting 6AV6644-…
Configuration on request
MP 277 8" Touch vertical,
rear-mounting 6AV6643-…
With emergency-off button and
3 short-stroke keys with LEDs
on the front
Configuration on request
ST80_2013_EN_Kap06.book Seite 45 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Food and beverages industry/pharmaceuticals
Flat Panels with stainless steel front
6/46 Siemens ST 80 / ST PC · 2013
6
Overview
Flat Panel 15" Touch INOX,
Flat Panel 15" Touch INOX (enclosed),
Flat Panel 19" Touch INOX,
Flat Panel 19" Touch INOX (enclosed)
The Flat Panels with touch screen and stainless steel front are
designed as a display and operating unit for SIMATIC PCs in the
food and beverages industry, pharmaceuticals and related
industries.
They are easy to clean and can be installed in production areas
subjected to splashes in a suitable control cabinet.
Design
Functions compatible with the SIMATIC HMI Standard Flat
Panels
Enclosure seal EPDM, sulfur-free
Decorative membrane laminated over display, no display
cutout
240 grain brushed stainless steel surface
The Flat Panels 15" Touch INOX and 19" Touch INOX VESA are
fully enclosed and are suitable for space-saving mounting on a
support system. The cables are then run in the supporting tube.
ST80_2013_EN_Kap06.book Seite 46 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Food and beverages industry/pharmaceuticals
Flat Panels with stainless steel front
6/47
Siemens ST 80 / ST PC · 2013
Technical specifications
Ordering data
Order No.
More information
Customized modification options
Customized design
Customized flange connection
Cable length up to 30 m
Drafting a quotation
SIMATIC HMI specialists define the product modifications
precisely in accordance with customer requirements.
This is followed by drafting a quotation with:
Non-recurring costs
Prototype costs
Standard unit prices
and the marginal conditions in the form of a product
agreement (e.g. minimum quantity).
The defined device can then be easily ordered using this
product agreement and a customized order number.
Flat Panel
15" Touch, INOX 15" Touch INOX
fully enclosed 19" Touch, INOX 19" Touch INOX
fully enclosed
General features
Power supply 24 V DC 24 V DC 24 V DC 24 V DC
Display 15.1" TFT Touch 15.1" TFT Touch 19.1" TFT Touch 19.1" TFT Touch
Resolution (pixels) 1024 x 768 1024 x 768 1280 x 1024 1280 x 1024
MTBF of backlighting (at 25 °C) approx. 50 000 hours CCFL backlighting
Special features Without front USB interface OSD operation not
accessible; values preset Without front USB interface OSD operation not
accessible; values preset
Front
Material Stainless steel 1.4301, polyester-based membrane
Surface Hairline finish, 240 grit abrasive grain
Device seal EPDM flat seal EPDM flat seal EPDM flat seal
Special features Decorative membrane drawn across display
Ambient conditions
Degree of protection On the front: IP66K,
NEMA 4, 4x and 12;
on rear: IP20
Complete IP65,
NEMA 4 On the front: IP66K,
NEMA 4, 4x and 12;
on rear: IP20
Complete IP66K,
NEMA 4, 4x and NEMA 12
Ambient temperature
during operation 0 ... 50 °C 0 ... +40 °C at an angle of
up to +/- 20° from the verti-
cal
0 ... 50 °C 0 ... +40 °C
Relative humidity Max. 85% (no condensation)
Transport/storage temperature -20 °C to +60 °C
Approvals CE, cULus CE, cULus CE, cULus CE, cULus
Sector Food & beverages,
pharmaceuticals Pharmaceuticals Food & beverages, phar-
maceuticals Food & beverages, phar-
maceuticals
Dimensions
External dimensions
(W x H x D in mm) 483 x 310 383 x 324 x 72 483 x 400 483 x 399 x 61
Installation cutout (W x H x D in mm) 450 x 296 450 x 380
Special features Clamping frame Tiltable customized flange
for mounting on control
cabinet, sealed by bellows
Clamping frame fully enclosed, VESA 100
Weight Approx. 7 kg Approx. 12 kg Approx. 10 kg Approx. 12 kg
Flat Panel 15" Touch INOX 6AV7486-2TA10-1AA0
Flat Panel 15" Touch INOX
fully enclosed 6AV7476-...
Configuration on request
Flat Panel 19" Touch INOX 6AV7486-4TA01-0AA0
Cable 1.8 m enclosed
Flat Panel 19" Touch INOX
fully enclosed 6AV7486-4TA11-0AA0
Cable 1.8 m pre-assembled
ST80_2013_EN_Kap06.book Seite 47 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Food and beverages industry/pharmaceuticals
HMI stainless steel operator stations
6/48 Siemens ST 80 / ST PC · 2013
6
Overview
SIMATIC HMI Panels or Panel PCs mounted in a stainless steel
cabinet as a ready-to-install and ready-to-use terminal that is
ergonomic and functional, and has a high degree of protection
(complete degree of protection IP66K) as well as tested heat
balance.
The populated and wired turnkey solutions are based on the
hygienic design requirements of the food and beverages
industry as well as other hygiene and wet areas, pharmaceu-
ticals, fine chemicals and semiconductor production.
Design
Control box completely assembled, wired, tested,
with passive cooling
Design of stainless steel terminal
For Panels and Panel PCs
Angular surfaces so that liquids can run off
Prepared for stand mounting
With integrated handles at sides.
High complete degree of protection
Screwed-on rear panel
Cable inlet through stand and flange
Simple to clean
No sharp corners or edges
No dead spaces
Hairline finish of surface with 240 grade grain
More information
Customized modification options
Other HMI devices, display sizes and resolutions
External stainless steel keyboard, e.g. without short-stroke
keys with piezo technology
Modification of the front/enclosure design
(hygiene test optional) and cable routing
Specific flange from enclosure manufacturers
Breather gland
Use in extended ambient temperature range,
e.g. -20 °C to +60 °C
- Air-water heat exchanger (internal)
- "Temperature Extension Kit" plus active heating and cooling
elements
Certification/approvals
LGA Certificate "Hygiene-tested"
Inspection certificate of the Munich University of Technology
IPA Fraunhofer Institute
These modifications are defined by HMI specialists in consul-
tation with the customer who then receives a specific offer.
A product agreement with minimum quantities is required for the
implementation of customized modifications. Please contact
your local/national Siemens HMI representative.
ST80_2013_EN_Kap06.book Seite 48 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Oil & gas/chemicals/shipbuilding
Oil & gas/chemicals/shipbuilding
6/49
Siemens ST 80 / ST PC · 2013
Overview
The requirements of the sectors oil and gas, chemicals and
shipbuilding are diverse and range from use in areas subject to
explosion hazard involving drill pipes, use in the extended
temperature range (outdoor) and in direct sunlight, all the way to
use on the darkened bridge of a ship.
In the case of drill pipes in the oil and gas industry and also in
the chemicals industry, the following product features are
important:
Certification for areas subject to explosion hazard in Zones 2
and 22 in accordance with ATEX, FM Class I, Div. 2 and
UL Haz. Loc.
Daylight-readable display
Use in sub-zero temperatures and in regions with high
atmospheric humidity
Resistant to harsh environmental conditions
Stainless steel surfaces are demanded for increased resis-
tance to chemicals
The following features are required in shipbuilding:
Dimmable display down to complete black-out
Marine Type certification such as Germanischer Lloyd and
others
HMI sector products
MP 377 15" Touch daylight readable
ST80_2013_EN_Kap06.book Seite 49 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Oil & gas/chemicals/shipbuilding
MP 377 15" Touch daylight readable
6/50 Siemens ST 80 / ST PC · 2013
6
Overview
Ideal for use in the oil & gas industry:
- Certification in accordance with ATEX for Zone 2/22,
UL Haz. Loc.,
- FM Class I, Div.2
- Bright, daylight-readable display
- Rugged front for harsh environmental conditions
- UV-protected decorative membrane
- High degree of protection
- Can be used in the extended outdoor temperature range at
-30 °C to +70 °C with the TEK option in an air-conditioned
control cabinet
Ideal for use in shipbuilding:
- Diverse shipbuilding certificates (available soon)
- 100% dimmable display backlighting, local and centralized
- Console installation without special measures or restrictions
- High-contrast display with wide reading angle
- Design version with black frame possible
• Features:
- Daylight-readable, bright and dimmable LCD display
- Splashwater-protected (IP66)
- Rugged aluminum front, impact-resistant, UV-protected
- Capacitive touch with 3 mm glass for harsh environmental
conditions
- Touch operation with thin gloves
- Outdoor applications with extended temperature range
(option)
- ATEX Zone 2/22, FM Class I, Div. 2, UL Haz. Loc.
- Marine certificates:
DNV, GL, NK, ABS, LRS, CCS, RINA
-Fan-free
Benefits
A panel for applications inside and outside the production hall
Extremely easy to read under diverse conditions
Ergonomic dimmer function for optimal reading in control
desks
Can be connected to centralized dimming potentiometer
(via PLC)
Familiar HMI functions (exception: Sm@rt option and
high-speed keys), no new training
Application
The Panel has a daylight-readable and dimmable display,
making it predestined for use in control desks for, e.g. drill
strings (oil & gas industry), ships (shipbuilding) and other
exposed areas up to outdoor applications with the
TEK Temperature Extension Kit option.
Design
The "MP 377 15" Touch daylight readable" has a powder-coated
milled aluminum front that is impact-resistant, scratch-proof and
highly resistant to chemicals.
Touch operation uses projected capacitive technology
protected against humidity, heat and dirt in harsh environments
by a 3-mm pane of glass, without reflective membranes.
The refined polyester-based decorative membrane is
UV-resistant and protected against yellowing and embrittling.
The LED-backlit and dimmable display is designed using trans-
flective technology that allows a higher contrast than conven-
tional, transmissive displays in extremely bright environments.
The LED backlighting is dimmable using a slider on the process
picture or centrally via the controller. Dimming is carried out
using a gradation curve and is thus optimally ergonomically
matched to the human eye.
The Panel is based on the field-proven electronics card of the
MP 377 with WinCC flexible functionality and the familiar inter-
faces. The entire mechanical design is prepared for good
convection and temperature balance, for long service life, and
for operation onboard ship, or other vehicles with corresponding
shock and vibration stresses.
ST80_2013_EN_Kap06.book Seite 50 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Oil & gas/chemicals/shipbuilding
MP 377 15" Touch daylight readable
6/51
Siemens ST 80 / ST PC · 2013
Technical specifications
Ordering data
Order No.
More information
Customized modification options
Integration into customized turnkey operator panels
Customized design
Drafting a quotation
SIMATIC HMI specialists define the product modifications
precisely in accordance with customer requirements.
This is followed by drafting a quotation with:
Non-recurring costs
Prototype costs
Standard unit prices
and the marginal conditions in the form of a product
agreement (e.g. minimum quantity).
The defined device can then be easily ordered using this
product agreement and a customized Order No.
Multi Panels MP 377 15" Touch
daylight readable
General features
Display 15" TFT, transflective
Brightness typ. 800 cd/m
2
Contrast typ. 1000:1
Reading angle 160°
Resolution 1024 x 768
MTBF of backlit display (at 25°C) 50,000 hrs LED backlighting,
dimmable 0 (off) to 100%
Input unit Touch, projected capacitive
Power supply 24 V DC, typ. 1.5 A
Special features Daylight-readable
Front
Material Aluminum, Autotex XE, glass
Surface Powder-coated aluminum, polyes-
ter-based decorative membrane,
glass (Mohs 7)
Device seal HC / EPDM 4x4
Ambient conditions
Degree of protection Front IP66, rear IP20
Ambient temperature during operation Front -30 °C to +70 °C, rear 0 °C to
+50 °C, changeover time >= 3 min.
Relative humidity 10% to 90%, without condensation
Vibration IEC 60068, Part 2–6 (sine),
constant acceleration 1 g
Shock IEC 60068, Part 2–29, 15 g peak
value, 11 ms duration
Transport and storage conditions IEC 60721-3-2, Class 2M2
Transport/storage temperature -40 °C to +80 °C
Approvals CE, cULus, C-Tick, ATEX Zone 2/22,
UL haz. loc., FM Class I, Div. 2, ship-
building certificates available soon
Sector Oil & gas, ship, outdoor
Can be connected to SIMATIC PC Multi Panels
HMI software
HMI engineering software Configurable from WinCC flexible
2008, SP1 with add-ons
HMI Runtime software
Special features Console mounting with an inclination
of up to 90°, installation cutout as on
MP 377 15" Touch (W x H)
Dimensions
External dimensions (W x H x D in mm) 400 x 315.5 x 106
Installation cutout (W x H x D in mm) 365.6 x 287 x 100
Weight 4.6 kg
MP 377 15" Touch
daylight readable 6AV6644-8AB20-0AA1
Multi Panel 15" Touch with display
suitable for natural-light viewing
ST80_2013_EN_Kap06.book Seite 51 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Customized Automation
Notes
6/52 Siemens ST 80 / ST PC · 2013
6
ST80_2013_EN_Kap06.book Seite 52 Dienstag, 6. August 2013 10:56 10
© Siemens AG 2013
Siemens ST 80 / ST PC · 2013
7
7/2 Siemens Industry Training
7/3 Course overview
7/4 Standards and approvals
7/5 Partners at Industry Automation and
Drive Technologies
7/5 Siemens contacts worldwide
7/6 WinCC Competence Centers
7/7 Solution Partner
7/8 Siemens Automation Cooperates
with Education
7/8 Applicable practical know-how
7/10 Online Services
7/10 Information and Ordering in the Internet
and on DVD
7/11 Information and Download Center
Social Media, Mobile Media
7/12 Industry Services
7/13 For the entire life cycle
7/17 Siemens Service Option
for SIMATIC PC / PG
7/18 Expertise and services relating to
all aspects of PC-based Automation
7/19 Software Licenses
7/21 Index
7/25 Order No. Index
7/27 Length key for connecting cables
7/28 Catalog improvement suggestions
7/32 Conditions of sale and delivery
Appendix
Kap07_Anhang_en.book Seite 1 Montag, 5. August 2013 4:47 16
© Siemens AG 2013
Appendix
Siemens Industry Training
7/2 Siemens ST 80 / ST PC · 2013
7
Faster and more applicable know-how:
Hands-on training from the manufacturer
Siemens Industry Training provides you with comprehensive
support in solving your tasks.
Training by the market leader in the industry enables you to
make independent decisions with confidence. Especially where
the optimum and efficient use of products and plants are con-
cerned. You can eliminate deficiencies in existing plants, and
exclude expensive faulty planning right from the beginning.
First-class know-how directly pays for itself: In shorter startup
times, high-quality end products, faster troubleshooting and re-
duced downtimes. In other words, increased profits and lower
costs.
Achieve more with Siemens Industry Training
Shorter times for startup, maintenance and servicing
Optimized production operations
Reliable configuration and startup
Minimization of plant downtimes
Flexible plant adaptation to market requirements
Compliance with quality standards in production
Increased employee satisfaction and motivation
Shorter familiarization times following changes in technology
and staff
Contact
Visit our site on the Internet at:
www.siemens.com/sitrain
or let us advise you personally.
Siemens Industry Training Customer Support Germany:
Phone: +49 (911) 895-7575
Fax: +49 (911) 895-7576
E-Mail: info@sitrain.com
Highlights Siemens Industry Training
Top trainers
Our trainers are skilled teachers with direct practical experience.
Course developers have close contact with product develop-
ment, and directly pass on their knowledge to the trainers.
Practical experience
The practical experience of our trainers enables them to teach
theory effectively. But since theory can be pretty drab, we attach
great importance to practical exercises which can comprise up
to half of of the course time. You can therefore immediately im-
plement your new knowledge in practice. We train you on state-
of-the-art methodically/didactically designed training equip-
ment. This training approach will give you all the confidence you
need.
Wide variety
With a total of about 300 local attendance courses, we train the
complete range of Siemens Industry products as well as interac-
tion of the products in systems.
Tailor-made training
We are only a short distance away. You can find us at more than
50 locations in Germany, and in 62 countries worldwide. You
wish to have individual training instead of one of our
300 courses? Our solution: We will provide a program tailored
exactly to your personal requirements. Training can be carried
out in our Training Centers or at your company.
The right mixture: Blended learning
"Blended learning" is a combination of various training media
and sequences. For example, a local attendance course in a
Training Center can be optimally supplemented by a teach-your-
self program as preparation or follow-up. Additional effect:
Reduced traveling costs and periods of absence.
Kap07_Anhang_en.book Seite 2 Montag, 5. August 2013 4:47 16
© Siemens AG 2013
Appendix
Siemens Industry Training
7/3
Siemens ST 80 / ST PC · 2013
Training offer for SIMATIC HMI
This page contains an overview of the SITRAIN training offer for
SIMATIC HMI operator control and monitoring systems as well as
for PC-based Automation.
Depending on your demands we’ll make you fit for specific ap-
plications or teach you important background knowledge about
products and systems.
All courses contain the largest possible share of practical exer-
cises so that training can be carried out very intensively in very
small groups.
Further information regarding course contents, dates and prices
can be found in the Internet at:
www.siemens.com/sitrain
SITRAIN courses for SIMATIC HMI / PC-based Automation
SIMATIC WinCC based onTIA Portal
SIMATIC WinCC flexible
SIMATIC WinCC V7.x
SIMATIC WinCC V7.x Market-specific Solutions
Commissioning engineers,
configuration engineers
Programmers Service personnel
Project managers, project team members Operators, users
Decision makers, sales personnel Maintenance personnel
Title Target Group Duration/
Medium Short title
SIMATIC TIA Portal WinCC SCADA retraining course
✔✔✔✔
3 days TIA-WCCSUP
SIMATIC TIA Portal WinCC on the machine level
✔✔✔✔
3 days TIA-WCCM
SIMATIC TIA Portal WinCC SCADA
✔✔✔✔
5 days TIA-WCCS
SIMATIC TIA Portal WinCC on the machine level
✔✔✔✔
WBT WT-TIAWMUP
TIA
TIA
TIA
TIA
SIMATIC WinCC flexible, system course 1
✔✔✔✔
3 days ST-WCCFSYS1
SIMATIC WinCC flexible, system course 2
✔✔✔ ✔
3 days ST-WCCFSY2
SIMATIC WinCC, system course
✔✔✔✔
5 days ST-BWINCCS
SIMATIC WinCC, advanced configuration, options for networking and
access to database
✔✔
5 days ST-BWINOND
ANSI-C in the SIMATIC World, Introduction
✔✔✔ ✔
5 days ST-SIMACE
Energy management
Energy management with SIMATIC powerrate for WinCC
✔✔✔✔
3 days ST-EMPRWCC
Energy management with B.Data
✔✔✔✔
4 days ST-EMBDATA
These courses are based on the new engineering platform TIA Portal.
TIA
Kap07_Anhang_en.book Seite 3 Montag, 5. August 2013 4:47 16
© Siemens AG 2013
Appendix
Standards and approvals
7/4 Siemens ST 80 / ST PC · 2013
7
Operating system licenses for SIMATIC PC/PG
The accompanying operating system license is only valid for
installation on the supplied SIMATIC PC/PG.
Installation can only be performed on these SIMATIC systems in
accordance with Microsoft OEM licensing regulations.
Standards UL (U) and CSA (C)
All HMI products comply with the standards UL (U) and CSA (C),
or the approval procedure has been applied for.
Products which have no approval are specially marked
(see ordering data of the products).
CE marking
The electronic products described in this catalog comply with
the requirements and protection objectives of the following
EC directives insofar as they relate to the product concerned.
They also comply with the corresponding harmonized European
standards (EN) published for these products in the Official
Journals of the European Community.
Directive 2004/108/EC of the European Parliament and
Council on the approximation of the laws of the Member States
relating to electromagnetic compatibility (EMC Directive)
Directive 2006/95/EC of the European Parliament and of the
Council on the harmonization of the laws of Member States
relating to electrical equipment designed for use within certain
voltage limits (Low Voltage Directive)
Directive 94/9/EC of the European Parliament and the Council
on approximation of the laws of the Member States concern-
ing equipment and protective systems intended for use in
potentially explosive atmospheres (ATEX Directive).
Directive 1999/5/EC of the European Parliament and of the
Council on radio equipment and telecommunications terminal
equipment and the mutual recognition of their conformity
(RTTE Directive)
The originals of the declarations of conformity are kept available
for the responsible supervisory authorities at:
SIMATIC HMI:
Siemens AG
I IA AS S ID
Postfach 48 48
90327 Nürnberg
Germany
SIMATIC, SIMATIC NET, SIMATIC PC:
Siemens AG
IA AS EWA
Postfach 19 63
92209 Amberg
Germany
Note on the EMC Directive:
The installation instructions in the manuals must be adhered to
when installing and operating the products described in this cat-
alog. These contain, for example, important information on in-
stallation in cabinets and on the use of shielded cables.
Kap07_Anhang_en.book Seite 4 Montag, 5. August 2013 4:47 16
© Siemens AG 2013
Appendix
Partners at Industry Automation and Drive Technologies
Siemens contacts worldwide
7/5
Siemens ST 80 / ST PC · 2013
Overview
At Siemens Industry Automation and Drive Technologies, more
than 85 000 people are resolutely pursuing the same goal: long-
term improvement of your competitive ability. We are committed
to this goal. Thanks to our commitment, we continue to set new
standards in automation and drive technology. In all industries –
worldwide.
At your service locally, around the globe for consulting, sales,
training, service, support, spare parts ... on the entire Industry
Automation and Drive Technologies range.
Your personal contact can be found in our Contacts Database at:
www.siemens.com/automation/partner
You start by selecting a
Product group,
Country,
•City,
• Service.
Kap07_Anhang_en.book Seite 5 Montag, 5. August 2013 4:47 16
© Siemens AG 2013
Appendix
Partners at Industry Automation and Drive Technologies
WinCC Competence Centers
7/6 Siemens ST 80 / ST PC · 2013
7
WinCC Competence Centers
The WinCC Competence Centers are Siemens-internal partners.
They offer a wide range of products and services designed to
make optimal economic and system-oriented use of the open-
ness and integration capability of WinCC.
In addition to the development of standard solutions/add-on
products, they are authorized to implement customized/
industry-specific solutions in the areas of application develop-
ment and system integration on the basis of WinCC. The portfolio
is rounded off with consulting services, project-related training,
and workshops for decision-makers and users.
Sector competence in addition to automation expertise and
WinCC system know-how ensure professional and efficient solu-
tions. The software is, of course, developed in compliance with
recognized standards on the basis of certified quality manage-
ment in accordance with DIN ISO 9001.
You can find more information on the Internet at:
www.siemens.com/wincc-competence-center
Kap07_Anhang_en.book Seite 6 Montag, 5. August 2013 4:47 16
© Siemens AG 2013
Appendix
Partners at Industry Automation and Drive Technologies
Siemens Solution Partner Automation
7/7
Siemens ST 80 / ST PC · 2013
Overview
Siemens Solution Partner Automation
Solution Partner: Highest quality - guaranteed
The products and systems from Siemens Industry Automation
and Drive Technologies offer the ideal platform for all automation
applications.
Under the name of Siemens Solution Partner Automation,
selected system integrators around the world act as uniformly
qualified solution providers for the Siemens range of products
and services in the fields of automation and drives. Day after
day, they utilize their qualified product and system know-how as
well as their excellent industry expertise to your advantage – for
all requirements.
The partner emblem is the guarantee and indicator of proven
quality. The basis for this are defined quality features that identify
Solution Partners as reliable and competent solution providers:
Solution quality
Always a good result with tried and tested solutions expertise.
Expert quality
Certified technical competence ensures maximum efficiency.
Project quality
With proven project experience straight to the target.
Portfolio quality
Comprehensive portfolio for state-of-the-art solutions from a
single source.
Solution Partner Finder
The Siemens Solution Partner Program helps you to find the
optimum partner for your specific requirements.
Support is provided by the Solution Partner Finder, a compre-
hensive online platform that showcases the profiles of all our
solution partners. You can convince yourself of the competence
of the respective Solution Partner by means of the references
provided. Various search criteria are available for this purpose.
Once you have located a partner, you are only one small step
away from contacting them.
Find the right partner here for your specific task and convince
yourself of the solution competence provided:
www.siemens.com/automation/partnerfinder
Additional information on the Siemens Solution Partner Program
is available online at:
www.siemens.com/automation/solutionpartner
Kap07_Anhang_en.book Seite 7 Montag, 5. August 2013 4:47 16
© Siemens AG 2013
Appendix
Siemens Automation Cooperates with Education
Applicable practical know-how
7/8 Siemens ST 80 / ST PC · 2013
7
Comprehensive teaching support for educational institutions
Siemens Automation Cooperates with Education (SCE)
offers a global system for sustained support of technical skills.
SCE supports educational institutions in their teaching assign-
ment in the industrial automation sector and offers added value
in the form of partnerships, technical expertise, and know-how.
As the technological leader, our comprehensive range of
services can support you in the knowledge transfer for
Industry 4.0.
Our services at a glance
Training curriculums for your lessons
Trainer packages for hands-on learning
Courses convey up-to-date, specialist knowledge
Support for your projects/textbooks
Complete didactic solutions from our partners
Personal contact for individual support
Training curriculums for your lessons
Use our profound industrial know-how for practice-oriented
and individual design of your course. We offer you more than
100 didactically prepared training curriculums on the topics of
automation and drives technology free of charge. These
materials are perfectly matched to your curricula and sylla-
buses, and optimally suited for use with our trainer packages.
This takes into account all aspects of a modern industrial
solution: installation, configuration, programming, and commis-
sioning. All documents, including projects, can be individually
matched to your specific requirements.
Particular highlights:
With the new SIMATIC PCS 7 curriculums and trainer
packages, you can pass on basic, practice-oriented PCS 7
knowledge at universities within about 60 hours
(= 1 semester), using plant simulation.
The new TIA Portal training materials for SIMATIC S7-1200 are
available in English, German, French, Italian, Spanish and
Chinese for download.
www.siemens.com/sce/documents
Trainer packages for hands-on learning
Our SCE trainer packages offer a specific combination of
original industrial components which are perfectly matched to
your requirements and can be conveniently used in your course.
These price reduced bundles available exclusively to schools
include innovative and flexible hardware and software
packages. SCE can currently offers more than 90 SCE trainer
packages including related equipment. These cover both the
factory and process automation sectors. You can use them to
impart the complete course contents on industrial automation at
a very low cost.
Trainer packages are available for:
Introduction to automation technology with LOGO! logic
module and SIMATIC S7-1200 compact controller
PLC engineering with SIMATIC S7 hardware and STEP 7
software (S7-300, S7-1500 and TIA Portal)
Operator control and monitoring with SIMATIC HMI
Industrial networking over bus systems with SIMATIC NET
(PROFINET, PROFIBUS, IO-Link)
Sensor systems with VISION, RFID and SIWAREX
Process automation with SIMATIC PCS 7
Power Monitoring Devices SENTRON PAC 4200
Motor Management SIMOCODE
Networked drive and motion technologies with SINAMICS/
SIMOTION
CNC programming with SinuTrain
Important ordering notes:
Only the following institutions are authorized to obtain trainer
packages: vocational schools, Colleges and Universities,
in-house vocational training departments, non commercial
research institutions and non commercial training departments.
To purchase a trainer package, you require a specific end-use
certificate, which you can obtain from your regional sales office.
www.siemens.com/sce/tp
Kap07_Anhang_en.book Seite 8 Montag, 5. August 2013 4:47 16
© Siemens AG 2013
Appendix
Siemens Automation Cooperates with Education
Applicable practical know-how
7/9
Siemens ST 80 / ST PC · 2013
Comprehensive teaching support for educational institutions (continued)
Courses convey up-to-date specialist knowledge
Profit from our excellent know-how as the leader in industrial
technologies. We offer you specific courses for automation and
drive technology worldwide. These support you in the practice-
oriented transferring of product and system know-how, are in
conformance with curriculums, and derived from the training
fields. Compact technical courses especially for use at univer-
sities are also available.
Our range of courses comprises a wide variety of training
modules based on the principle of Totally Integrated Automation
(TIA). The focus is on the same subject areas as with the SCE
trainer packages.
Every PLC and drive course is oriented on state-of-the-art
technology. Your graduates can thus be prepared optimally for
their future professional life.
In some countries we are offering classes based on our training
curriculums. Please inquire with your SCE contact partner.
www.siemens.com/sce/contact
Support for your projects/textbooks
Automation and drive technology is characterized by continuous
and rapid developments. Service and Support therefore play an
important role.
We can provide you with consulting for selected projects and
support from your personal SCE contact as well as our web
based and regional Customer Support.
As a particular service, SCE supports technical authors with our
know-how as well as with intensive technical consulting.
Siemens library of special textbooks covering the industrial
automation sector provides an additional resource for you and
your students. These can be found at the SCE web site.
www.siemens.com/sce/contact
www.siemens.com/sce/books
Complete didactic solutions
Our partners for learning systems offer a wide range of training
systems and solutions for use in your courses or laboratory.
These models have been designed based on our trainer
packages and thus save you the time and cost of self-
construction of individual components. The Partner systems
provide you with simple and effective help in the fulfillment of
your teaching assignment.
www.siemens.com/sce/partner
Contact for individual support
You can find your personal SCE contact on our Internet site. Your
local SCE Promoter will answer all your questions concerning the
complete SCE offering, and provide you with timely and
competent information about innovations. When you encounter
challenges, you can profit from our global team of excellence.
If a direct SCE contact is not listed for your country, please
contact your local Siemens office.
www.siemens.com/sce/contact
SCE Support Finder for your Internet request
You are an educator and need support on the topic of industry
automation? Send us your request:
www.siemens.com/sce/supportfinder
6FDQWKH45
FRGHIRUIXUWKHU
LQIRUPDWLRQ
6&(KRPHSDJH
Kap07_Anhang_en.book Seite 9 Montag, 5. August 2013 4:47 16
© Siemens AG 2013
Appendix
Online Services
Information and Ordering
in the Internet and on DVD
7/10 Siemens ST 80 / ST PC · 2013
7
Siemens Industry Automation and Drive Technologies in the WWW
A detailed knowledge of the range of products and services
available is essential when planning and configuring automation
systems. It goes without saying that this information must always
be fully up-to-date.
Siemens Industry Automation and Drive Technologies has
therefore built up a comprehensive range of information in the
World Wide Web, which offers quick and easy access to all data
required.
Under the address
www.siemens.com/industry
you will find everything you need to know about products, sys-
tems and services.
Product Selection Using the Interactive Catalog CA 01 of Industry
Detailed information together with convenient interactive
functions:
The interactive catalog CA 01 covers more than 80 000 products
and thus provides a full summary of the Siemens Industry Auto-
mation and Drive Technologies product base.
Here you will find everything that you need to solve tasks in the
fields of automation, switchgear, installation and drives.
All information is linked into a user interface which is easy to
work with and intuitive.
After selecting the product of your choice you can order at the
press of a button, by fax or by online link.
Information on the interactive catalog CA 01 can be found in the
Internet under
www.siemens.com/automation/ca01
or on DVD.
Easy Shopping with the Industry Mall
The Industry Mall is the virtual department store of Siemens AG
on the Internet. Here you have access to a huge range of prod-
ucts presented in electronic catalogs in an informative and at-
tractive way.
Data transfer via EDIFACT allows the whole procedure from
selection through ordering to tracking of the order to be carried
out online via the Internet.
Numerous functions are available to support you.
For example, powerful search functions make it easy to find the
required products, which can be immediately checked for avail-
ability. Customer-specific discounts and preparation of quotes
can be carried out online as well as order tracking and tracing.
Please visit the Industry Mall on the Internet under:
www.siemens.com/industrymall
Kap07_Anhang_en.book Seite 10 Montag, 5. August 2013 4:47 16
© Siemens AG 2013
Appendix
Online Services
Information and Download Center
Social Media, Mobile Media
7/11
Siemens ST 80 / ST PC · 2013
Downloading Catalogs
In addition to numerous other useful documents, you can also
find the catalogs listed on the back inside cover of this catalog
in the Information and Download Center. Without having to reg-
ister, you can download these catalogs in PDF format or increas-
ingly as digital page-turning e-books.
The filter dialog box above the first catalog displayed makes it
possible to carry out targeted searches. If you enter “MD 3” for
example, you will find both the MD 30.1 and MD 31.1 catalogs.
If you enter “ST 70” both the ST 70 catalog and the associated
news or add-ons are displayed.
Visit us on the web at:
www.siemens.com/industry/infocenter
Social Media
Connect with Siemens through social media: visit our social net-
working sites for a wealth of useful information, demos on prod-
ucts and services, the opportunity to provide feedback, to ex-
change information and ideas with customers and other
Siemens employees, and much, much more. Stay in the know
and follow us on the ever-expanding global network of social
media.
Connect with Siemens Industry at our central access point:
www.siemens.com/industry/socialmedia
Or via our product pages at:
www.siemens.com/automation
or
www.siemens.com/drives
To find out more about Siemens' current social media activities
visit us at:
www.siemens.com/socialmedia
Mobile Media
Discover the world of Siemens.
We are also constantly expanding our offering of cross-platform
apps for smartphones and tablets. You will find the current Sie-
mens apps at the app store (iOS) or at Google Play (Android).
The Siemens app, for example, tells you all about the history, lat-
est developments and future plans of the company – with infor-
mative pictures, fascinating reports and the most recent press
releases.
Kap07_Anhang_en.book Seite 11 Montag, 5. August 2013 4:47 16
© Siemens AG 2013
Appendix
Industry Services
Your machines and plant can do more
– with Industry Services.
7/12 Siemens ST 80 / ST PC · 2013
7
Whether it is production or process industry - in view of rising
cost pressure, growing energy costs, and increasingly stringent
environmental regulations, services for industry are a crucial
competitive factor in manufacturing as well as in process indus-
tries.
All over the world Siemens supports its customers with product,
system, and application-related services throughout the entire
life cycle of a plant. Right from the earliest stages of planning,
engineering, and building, all the way to operation and modern-
ization. These services enable customers to benefit from the
Siemens experts’ unique technological and product knowledge
and industry expertise.
Thus downtimes are reduced and the utilization of resources is
optimized. The bottom line: increased plant productivity, flexibil-
ity, and efficiency, plus reduced overall costs.
Discover all advantages of our service portfolio:
www.siemens.com/industry-services
Siemens supports its clients with technology based Services across a plants entire life cycle.
G_DA65_EN_00270
Online Support
Technical Support
Spare Parts
Repair Services
Field Services
Training
Gt¡GM
v¡Gz
GlGM
lGz
G{GjGMG
lGz
t¡GMGv¡Gz
lGMGlG
zG
GwGtGMG
jGt
GlGM
lGz
G{GjGMG
lGz
GlGMG
lGz
G{GjGMG
lGz
Engineer
& Build
Operation
Modernization
Planning
Planning
Modernization
Operation
Engineer
& Build
Kap07_Anhang_en.book Seite 12 Montag, 5. August 2013 4:47 16
© Siemens AG 2013
Appendix
Industry Services
Industry Services
for the entire life cycle
7/13
Siemens ST 80 / ST PC · 2013
Online Support
Online support is a comprehensive information system for all
questions relating to products, systems, and solutions that
Siemens has developed for industry over time. With more than
300,000 documents, examples and tools, it offers users of auto-
mation and drive technology a way to quickly find up-to-date in-
formation. The 24-hour service enables direct, central access to
detailed product information as well as numerous solution exam-
ples for programming, configuration and application.
The content, in six languages, is increasingly multimediabased
– and now also available as a mobile app. Online support’s
“Technical Forum” offers users the opportunity to share informa-
tion with each other. The “Support Request” option can be used
to contact Siemens’ technical support experts. The latest con-
tent, software updates, and news via newsletters and Twitter en-
sure that industry users are always up to date. www.siemens.com/industry/onlinesupport
Online Support App
Using the Online Support app, you can access over 300,000
documents covering all Siemens industrial products - anywhere,
any time. Regardless of whether you need help implementing
your project, fault-finding, expanding your system or are plan-
ning a new machine.
You have access to FAQs, manuals, certificates, characteristics
curves, application examples, product notices (e.g. announce-
ments of new products) and information on successor products
in the event that a product is discontinued.
Just scan the product code printed on the product directly using
the camera of your mobile device to immediately see all techni-
cal information available on this product at a glance. The graph-
ical CAx information (3D model, circuit diagrams or EPLAN mac-
ros) is also displayed. You can forward this information to your
workplace using the e-mail function.
The search function retrieves product information and articles
and supports you with a personalized suggestion list. You can
find your favorite pages – articles you need frequently – under
“mySupport”. You also receive selected news on new functions,
important articles or events in the News section.
The app is available free of charge from the Apple App Store
(iOS) or from Google Play (Android).
www.siemens.com/industry/onlinesupportapp
Technical Support
The ability to quickly analyze system and error messages and
take appropriate action are key factors in ensuring that plants
run safely and efficiently. Questions can arise at any time and in
any industry, whether it’s an individual product or a complete au-
tomation solution. Siemens technical support offers individual
technical assistance in matters related to functionality, how to
operate, applications, and fault clearance in industrial products
and systems – at any time and globally, over the phone, by e-
mail, or via remote access. Experienced experts from Siemens
answer incoming questions promptly. Depending on the require-
ments, they first consult specialists in the areas of development,
on-site services, and sales. Technical support is also available
for discontinued products that are no longer available. Using the
support request number, any inquiry can be clearly identified
and systematically tracked.
Scan the QR code
for information on
our Online Support
app.
Kap07_Anhang_en.book Seite 13 Montag, 5. August 2013 4:47 16
© Siemens AG 2013
Appendix
Industry Services
Industry Services
for the entire life cycle
7/14 Siemens ST 80 / ST PC · 2013
7
Spare Parts
Drive and automation systems must be available at all times.
Even a single missing spare part can bring the entire plant to a
standstill – and result in substantial financial losses for the oper-
ator. The spare parts services from Siemens protects against
such losses – with the aid of quickly available, original spare
parts that ensure smooth interaction with all other system com-
ponents. Spare parts are kept on hand for up to ten years; de-
fective parts can be returned. For many products and solutions,
individual spare parts packages ensure a preventive stock of
spare parts on-site. The spare parts services is available around
the world and around the clock. Optimum supply chain logistics
ensure that replacement components reach their destination as
quickly as possible. Siemens’ logistics experts take care of plan-
ning and management as well as procurement, transportation,
customs handling, warehousing, and complete order manage-
ment for spare parts.
Repair Services
Reliable electrical and electronic equipment is crucial for oper-
ating continuous processes. That is why it is essential that mo-
tors and converters always undergo highly specialized repair
and maintenance. Siemens offers complete customer and repair
services – on site and in repair centers – as well as technical
emergency services worldwide. The repair services include all
measures necessary to quickly restore the functionality of defec-
tive units. In addition, services such as spare parts logistics,
spare parts storage and rapid manufacturing are available to
plant operators in all verticals. With a global network of certified
repair shops operated by Siemens as well as third parties, Sie-
mens handles the maintenance and overhaul of motors, convert-
ers, and other devices as an authorized service partner.
Field Services
It’s a top priority in all industries: the availability of plants and
equipment. Siemens offers specialized maintenance services
such as inspection and upkeep as well as rapid fault clearance
in industrial plants – worldwide, continuously, and even with
emergency services as needed. The services include startup as
well as maintenance and fault clearance during operation. The
startup service includes checking the installation, function tests,
parameterization, integration tests for machines and plants, trial
operation, final acceptance, and employee training. All services,
including remote maintenance of drives, are also available as el-
ements of customized service contracts.
Kap07_Anhang_en.book Seite 14 Montag, 5. August 2013 4:47 16
© Siemens AG 2013
Appendix
Industry Services
Industry Services
for the entire life cycle
7/15
Siemens ST 80 / ST PC · 2013
Training
Increasingly, up-to-date knowledge is becoming a determining
factor in success. One of the key resources of any company is
well-trained staff that can make the right decision at the right mo-
ment and take full advantage of the potential. With SITRAIN –
Training for Industry, Siemens offers comprehensive advanced
training programs. The technical training courses convey exper-
tise and practical knowledge directly from the manufacturer.
SITRAIN covers Siemens’ entire product and system portfolio in
the field of automation and drives. Together with the customer,
Siemens determines the company’s individual training needs
and then develops an advanced training program tailored to the
desired requirements. Additional services guarantee that the
knowledge of all Siemens partners and their employees is al-
ways up-to-date.
Technical Consulting & Engineering Support
The efficiency of plants and processes leads to sustainable eco-
nomic success. Individual services from Siemens help save sub-
stantial time and money while also guaranteeing maximum
safety. Technical consulting covers the selection of products and
systems for efficient industrial plants. The services include plan-
ning, consulting, and conceptual design as well as product
training, application support, and configuration verification – in
all phases of a plants lifecycle and in all questions related to
product safety. Engineering support offers competent assis-
tance throughout the entire project, from developing a precise
structure for startup to product-specific preparation for imple-
mentation as well as support services in areas such as prototype
development, testing and acceptance.
Energy & Environmental Services
Efficient energy use and resource conservation – these top sus-
tainability concerns pay off – both for the environment and for
companies. Siemens offers integrated solutions that unlock all
technical and organizational potential for successful environ-
mental management. Customized consulting services are aimed
at sustainably lowering the cost of energy and environmental
protection and thus increasing plant efficiency and availability.
The experts provide support in the conceptual design and im-
plementation of systematic solutions in energy and environmen-
tal management, enabling maximum energy efficiency and opti-
mized water consumption throughout the entire company.
Improved data transparency makes it possible to identify sav-
ings potential, reduce emissions, optimize production pro-
cesses, and thereby noticeably cut costs.
Kap07_Anhang_en.book Seite 15 Montag, 5. August 2013 4:47 16
© Siemens AG 2013
Appendix
Industry Services
Industry Services
for the entire life cycle
7/16 Siemens ST 80 / ST PC · 2013
7
Modernization & Optimization Services
High machine availability, expanded functionality and selective
energy savings – in all industries, these are decisive factors for
increasing productivity and lowering costs. Whether a company
wants to modernize individual machines, optimize drive sys-
tems, or upgrade entire plants, Siemens’ experts support the
projects from planning to commissioning.
Expert consulting and project management with solution respon-
sibility lead to security and make it possible to specifically iden-
tify savings potential in production. This secures investments
over the long term and increases economic efficiency in opera-
tion.
Plant Maintenance & Condition Monitoring
Modern industrial plants are complex and highly automated.
They must operate efficiently in order to ensure the company’s
competitive strength. In addition, the steadily increasing net-
working of machines and plants require consistent security con-
cepts. Maintenance and status monitoring as well as the imple-
mentation of integrated security concepts by Siemens’ experts
support optimum plant use and avoid downtime. The services in-
clude maintenance management as well as consulting on main-
tenance concepts, including the complete handling and execu-
tion of the necessary measures. Complete solutions also cover
remote services, including analysis, remote diagnosis, and re-
mote monitoring. These are based on the Siemens Remote Ser-
vices platform with certified IT security.
Service Contracts
Making maintenance costs calculable, reducing interfaces,
speeding up response times, and unburdening the company’s
resources – the reduced downtimes that these measures
achieve increase the productivity of a plant. Service contracts
from Siemens make maintenance and repairs more cost-effec-
tive and efficient. The service packages include local and re-
mote maintenance for a system or product group in automation
and drive technology. Whether you need extended service peri-
ods, defined response times, or special maintenance intervals,
the services are compiled individually and according to need.
They can be adjusted flexibly at any time and used indepen-
dently of each other. The expertise of Siemens’ specialists and
the capabilities of remote maintenance thus ensure reliable and
fast maintenance processes throughout a plant’s entire lifecycle.
Kap07_Anhang_en.book Seite 16 Montag, 5. August 2013 4:47 16
© Siemens AG 2013
Appendix
Siemens Service Option for SIMATIC PC / PG
7/17
Siemens ST 80 / ST PC · 2013
Siemens Service Option for SIMATIC PC / PG
The expanded hardware service for SIMATIC PC/PG
products
Purchasing and registering this additional agreement for a
SIMATIC PC/PG extends the time period for free repairs of this
device to 36 months after delivery.
Scope of services of the service option within the period of
service (36 months):
•Free
1)
repair during the period of service at one of our
authorized repair centers near you
The addresses of our worldwide partners can be found on the
Internet at www.siemens.com/asis
Within the agreed contractual period, Siemens will bear the
costs that are incurred in the repair center (labor and
materials/replacement parts), which are needed to restore the
functions
2)
of the hardware
Siemens will also assume the return shipping costs of the
repaired device from the repair center to the customer
1)
Wear and tear as well as problems that arise due to improper handling of
the devices are not included.
2)
For hard disk defects that require the system to be restored, the repair
service will only cover restoring the installation to its original condition
ex works.
The uploading of additional application software, drivers and setting up the
operating software are not covered by the free repair service.
Ordering and registering the additional agreement:
Select the appropriate order number for the optional package
based on the family of products and place your order
Scope of delivery:
Description of services in 4 languages + service device label
with a license number for identifying the additional agreement
on the device
Activation of the service license number for a SIMATIC PC/
SIMATIC PG via the Internet (www.siemens.com/ped):
The registration must be completed within the first 90 days
after initial delivery of the device!
Product family Order No.
Service Option Order designation
SIMATIC Rack PC A5E00510072 36 months service
option for SIMATIC
Rack PC and Box PC
• SIMATIC IPC547
• SIMATIC IPC647
• SIMATIC IPC847
SIMATIC Box PC
• SIMATIC IPC227
• SIMATIC IPC427
• SIMATIC IPC627
• SIMATIC IPC827
SIMATIC Panel PC A5E00509961 36 months service
option for SIMATIC
Panel PCs
• SIMATIC IPC277
• SIMATIC IPC477D/
HMI IPC477
• SIMATIC HMI IPC577
• SIMATIC HMI IPC677
SIMATIC Field PG A5E00510007 36 months service
option for SIMATIC
Field PG M2/M3
• SIMATIC Field PG M2
• SIMATIC Field PG M3
Kap07_Anhang_en.book Seite 17 Montag, 5. August 2013 4:47 16
© Siemens AG 2013
Appendix
Expertise and services relating to all aspects of PC-based Automation
7/18 Siemens ST 80 / ST PC · 2013
7
Overview
Expertise and services relating to all aspects
of PC-based Automation
Do you require support with the dimensioning and options of a
PC-based Automation project, or even engineering support?
Specifically for this purpose, Siemens has established a team of
specialists in Cologne and Milan who work closely with Develop-
ment and Product Marketing and can thus provide our sales
departments worldwide with competent support in PC-based
Automation.
Our core competencies
Design of PC-based Automation systems from Siemens
Integrated, customer-specific technology (add-ons) using
high-level languages (C++) in Windows or real-time environ-
ments
Knowledge transfer/workshops for the integration of third-
party components, as well as for applications using the Open
Development Kit (ODK)
Technology and application know-how
Development of add-ons for WinAC and WinCC flexible
Reference applications
Fast recording of measured values
Software blocks for drives library
Customer-specific communications via Ethernet
(OPC/ActiveX, TCP socket)
Synchronous operation, flying shear, table interpolation for
electric and hydraulic axes
Integration of PCI cards into PC-based Automation applica-
tions (e.g. WinAC and ASi-Bus)
Customer-specific development and integration of C++
programs
Database connections
Integration of complex control algorithms
Contacts
Activation of the Competence Centers for your application via
your regional contact.
If you do not yet have a contact person in your region, just go to:
www.siemens.com/automation/partner
The latest information about the workshops offered can be found
on the Internet:
www.siemens.com/pc-based
Kap07_Anhang_en.book Seite 18 Montag, 5. August 2013 4:47 16
© Siemens AG 2013
Appendix
Software Licenses
7/19
Siemens ST 80 / ST PC · 2013
Overview
Software types
Software requiring a license is categorized into types.
The following software types have been defined:
Engineering software
Runtime software
Engineering software
This includes all software products for creating (engineering)
user software, e.g. for configuring, programming, parameteriz-
ing, testing, commissioning or servicing.
Data generated with engineering software and executable
programs can be duplicated for your own use or for use by third-
parties free-of-charge.
Runtime software
This includes all software products required for plant/machine
operation, e.g. operating system, basic system, system expan-
sions, drivers, etc.
The duplication of the runtime software and executable pro-
grams created with the runtime software for your own use or for
use by third-parties is subject to a charge.
You can find information about license fees according to use in
the ordering data (e.g. in the catalog). Examples of categories of
use include per CPU, per installation, per channel, per instance,
per axis, per control loop, per variable, etc.
Information about extended rights of use for parameteriza-
tion/configuration tools supplied as integral components of the
scope of delivery can be found in the readme file supplied with
the relevant product(s).
License types
Siemens Industry Automation & Drive Technologies offers vari-
ous types of software license:
Floating license
Single license
Rental license
Rental floating license
Trial license
Demo license
Demo floating license
Floating license
The software may be installed for internal use on any number of
devices by the licensee. Only the concurrent user is licensed.
The concurrent user is the person using the program. Use
begins when the software is started.
A license is required for each concurrent user.
Single license
Unlike the floating license, a single license permits only one
installation of the software per license.
The type of use licensed is specified in the ordering data and
in the Certificate of License (CoL). Types of use include for
example per instance, per axis, per channel, etc.
One single license is required for each type of use defined.
Rental license
A rental license supports the "sporadic use" of engineering
software. Once the license key has been installed, the software
can be used for a specific period of time (the operating hours do
not have to be consecutive).
One license is required for each installation of the software.
Rental floating license
The rental floating license corresponds to the rental license,
except that a license is not required for each installation of the
software. Rather, one license is required per object (for example,
user or device).
Trial license
A trial license supports "short-term use" of the software in a non-
productive context, e.g. for testing and evaluation purposes.
It can be transferred to another license.
Demo license
The demo license support the "sporadic use" of engineering soft-
ware in a non-productive context, for example, use for testing
and evaluation purposes. It can be transferred to another
license. After the installation of the license key, the software can
be operated for a specific period of time, whereby usage can be
interrupted as often as required.
One license is required per installation of the software.
Demo floating license
The demo floating license corresponds to the demo license,
except that a license is not required for each installation of the
software. Rather, one license is required per object (for example,
user or device).
Certificate of license (CoL)
The CoL is the licensee's proof that the use of the software has
been licensed by Siemens. A CoL is required for every type of
use and must be kept in a safe place.
Downgrading
The licensee is permitted to use the software or an earlier ver-
sion/release of the software, provided that the licensee owns
such a version/release and its use is technically feasible.
Delivery versions
Software is constantly being updated.
The following delivery versions
• PowerPack
• Upgrade
can be used to access updates.
Existing bug fixes are supplied with the ServicePack version.
PowerPack
PowerPacks can be used to upgrade to more powerful software.
The licensee receives a new license agreement and CoL
(Certificate of License) with the PowerPack. This CoL, together
with the CoL for the original product, proves that the new soft-
ware is licensed.
A separate PowerPack must be purchased for each original
license of the software to be replaced.
Upgrade
An upgrade permits the use of a new version of the software on
the condition that a license for a previous version of the product
is already held.
The licensee receives a new license agreement and CoL with
the upgrade. This CoL, together with the CoL for the previous
product, proves that the new version is licensed.
A separate upgrade must be purchased for each original license
of the software to be upgraded.
Kap07_Anhang_en.book Seite 19 Montag, 5. August 2013 4:47 16
© Siemens AG 2013
Appendix
Software Licenses
7/20 Siemens ST 80 / ST PC · 2013
7
Overview
ServicePack
ServicePacks are used to debug existing products.
ServicePacks may be duplicated for use as prescribed accord-
ing to the number of existing original licenses.
License key
Siemens Industry Automation & Drive Technologies supplies
software products with and without license keys.
The license key serves as an electronic license stamp and
is also the "switch" for activating the software (floating license,
rental license, etc.).
The complete installation of software products requiring license
keys includes the program to be licensed (the software) and the
license key (which represents the license).
Software Update Service (SUS)
As part of the SUS contract, all software updates for the respec-
tive product are made available to you free of charge for a period
of one year from the invoice date. The contract will automatically
be extended for one year if it is not canceled three months
before it expires.
The possession of the current version of the respective software
is a basic condition for entering into an SUS contract.
You can download explanations concerning license conditions from
www.siemens.com/automation/salesmaterial-as/catalog/en/
terms_of_trade_en.pdf
Kap07_Anhang_en.book Seite 20 Montag, 5. August 2013 4:47 16
© Siemens AG 2013
Appendix
Index
7/21
Siemens ST 80 / ST PC · 2013
Numerics
19" slide-in keyboard PS/2 with trackball ......................... 5/169
1-phase, 24 V DC/10 A (SITOP PSU100S)....................... 5/171
1-phase, 24 V DC/20 A (SITOP PSU100S)....................... 5/171
24 V DC uninterruptible power supplies .......................... 5/174
3-phase, 24 V DC/10 A (SITOP PSU300S)....................... 5/172
3-phase, 24 V DC/20 A (SITOP PSU300S)....................... 5/172
3-phase, 24 V DC/40 A (SITOP PSU300S)....................... 5/173
A
A whole world of operator control and monitoring ............... 1/6
Accessories for fully enclosed HMI devices ...................... 3/16
Adapter sets....................................................................... 3/16
Additional accessories..................................................... 2/101
Applicable practical know-how............................................ 7/8
Automotive industry............................................................ 6/30
B
Basic Panels....................................................................... 2/12
Basic Panels – Standard .................................................... 2/12
Batteries ........................................................................... 2/137
Battery module 1.2 Ah...................................................... 5/182
Battery module 2.5 Ah...................................................... 5/183
Battery module 3.2 Ah...................................................... 5/183
Battery module 7 Ah......................................................... 5/184
Battery module 12 Ah....................................................... 5/184
Box PC................................................................................ 5/27
BSP SIMATIC IPC V4.0 for RMOS3 .................................. 5/152
C
Catalog improvement suggestions .................................... 7/28
Charging station................................................................. 2/74
Comfort Panels................................................................... 2/26
Comfort Panels – Standard ................................................ 2/26
Communication – Industrial Ethernet ............................... 5/186
Communication – PROFIBUS........................................... 5/208
Conditions of sale and delivery.......................................... 7/32
Connecting cables ........................................................... 2/112
Connection options to SIMATIC IPCs............................... 5/186
Connection options to SIMATIC PCs................................ 5/208
Connectors/converters/adapters ..................................... 2/104
Controllers from other manufacturers................................. 2/79
Course overview................................................................... 7/3
C (continued)
CP 1604............................................................................ 5/187
CP 1612 A2 ...................................................................... 5/189
CP 1613 A2 ...................................................................... 5/191
CP 1616............................................................................ 5/188
CP 1623............................................................................ 5/192
CP 1628............................................................................ 5/193
CP 5512............................................................................ 5/219
CP 5603............................................................................ 5/209
CP 5612............................................................................ 5/221
CP 5613 A2 ...................................................................... 5/211
CP 5614 A2 ...................................................................... 5/213
CP 5622............................................................................ 5/223
CP 5623............................................................................ 5/215
CP 5624............................................................................ 5/217
CP 5711............................................................................ 5/225
Customized adaptations ...................................................... 6/4
Customized Automation ....................................................... 6/2
Customized hardware .......................................................... 6/6
Customized software.......................................................... 6/20
D
DC UPS module 6 A......................................................... 5/181
DC UPS module 15 A....................................................... 5/181
DC UPS module 40 A....................................................... 5/182
DC UPS with battery modules.......................................... 5/179
DC UPS with capacitors................................................... 5/176
Design products................................................................... 6/7
Devices with stainless steel front ....................................... 3/21
E
EC31................................................................................... 5/93
Embedded bundles/Software packages.......................... 5/101
Embedded Controller......................................................... 5/91
Examples of sector products ............................................. 6/26
Expansion components and accessories ........................ 5/153
Expansion modules.......................................................... 5/100
Expertise and services relating to
all aspects of PC-based Automation.................................. 7/18
Extension units ................................................................... 3/17
Kap07_Anhang_en.book Seite 21 Montag, 5. August 2013 4:47 16
© Siemens AG 2013
Appendix
Index
7/22 Siemens ST 80 / ST PC · 2013
7
F
Fasteners.......................................................................... 2/130
Fax form ............................................................................. 7/28
Flat Panels with stainless steel front................................... 6/46
Flat Panels, 10.4" for Panel PC........................................... 6/38
Flexible front design concept for HMI products................. 6/11
Food and beverages industry/pharmaceuticals ................ 6/39
Front panel 15" Touch and Key for Panel PCs,
resistant to honing oil ......................................................... 6/36
Front panel with motion keys at side .................................. 6/32
Fully enclosed HMI devices ................................................. 3/3
G
Gain transparency and lower costs ..................................... 1/2
General HMI accessories................................................... 2/96
General machine construction ........................................... 6/36
H
HARDNET-IE S7-REDCONNECT...................................... 5/194
HMI connecting components........................................... 2/105
HMI devices for hazardous areas ...................................... 3/25
HMI operator stations for the automobile industry ............. 6/30
HMI operator stations for turnkey products........................ 6/18
HMI Panels as rear-mounted devices ................................ 6/44
HMI software ........................................................................ 4/2
HMI Software in the TIA portal.............................................. 4/5
HMI stainless steel operator stations ................................. 6/48
I
IE FC RJ45 Plug 2 x 2....................................................... 2/110
Industrial monitors and thin clients................................... 5/117
Industrial PC......................................................................... 5/2
Industrial USB Hub 4.......................................................... 2/97
Industry Services................................................................ 7/12
Industry Services
for the entire life cycle ........................................................ 7/13
Information and Download Center ..................................... 7/11
Information and Ordering
in the Internet and on DVD................................................. 7/10
Input and output devices ................................................. 5/167
IP65 keyboards .................................................................. 3/19
IP65 membrane keyboard, desk version ......................... 5/168
K
Key Panels............................................................................ 2/6
L
Labeling strips.................................................................. 2/135
Length key for connecting cables...................................... 7/27
M
MASTERGUARD power supply........................................ 5/185
Memory media ................................................................. 2/116
Mobile Panel 277 10" Remote Operate .............................. 6/33
Mobile panel accessories .................................................. 2/99
Mobile Panels..................................................................... 2/44
Mobile Panels – 170 series................................................. 2/45
Mobile Panels – 270 series................................................. 2/52
MP 277 8" Touch control console ....................................... 6/13
MP 377 15" Touch daylight readable.................................. 6/50
O
OEM products .................................................................... 6/10
Oil & gas/chemicals/shipbuilding....................................... 6/49
Online Services .................................................................. 7/10
OPC server for Industrial Ethernet ................................... 5/201
OPC server for PROFIBUS ............................................... 5/229
Order No. Index.................................................................. 7/25
P
Panel PC............................................................................. 5/50
Panels and Panel PCs with stainless steel front................. 6/41
Partners at Industry Automation and Drive Technologies .... 7/5
PC I/O............................................................................... 5/156
PLCs from other manufacturers ......................................... 2/90
PN CBA OPC server......................................................... 5/203
Power supply unit............................................................. 2/100
Protective covers.............................................................. 2/122
Protective films ................................................................. 2/124
R
Rack PC................................................................................ 5/3
Remote Operate Software.................................................. 6/21
Renewable energy ............................................................. 6/27
RMOS3 real-time operating system ................................. 5/146
RMOS3 V3.50 real-time operating system ....................... 5/147
RMOS3-GNU V3.0............................................................ 5/149
RMOS3-GRAPHX V1.0 ..................................................... 5/151
RMOS3-TCP/IP V3.0......................................................... 5/150
RS485 bus connector....................................................... 2/109
Kap07_Anhang_en.book Seite 22 Montag, 5. August 2013 4:47 16
© Siemens AG 2013
Appendix
Index
7/23
Siemens ST 80 / ST PC · 2013
S
S7 OPC Redundancy for Industrial Ethernet.................... 5/205
S7 OPC Redundancy for PROFIBUS ............................... 5/230
S7 OpenModbusTCP ......................................................... 6/24
SCADA System SIMATIC WinCC ....................................... 4/88
SCADA System SIMATIC WinCC Open Architecture....... 4/146
SCD desk monitors SCD 19101 ....................................... 5/134
SCD monitors 1900 .......................................................... 5/136
Service sets...................................................................... 2/118
Siemens Automation Cooperates with Education ................ 7/8
Siemens contacts worldwide................................................ 7/5
Siemens Industry Training.................................................... 7/2
Siemens Service Option for SIMATIC PC / PG ................... 7/17
Siemens Solution Partner Automation .................................. 7/7
SIMATIC 505....................................................................... 2/89
SIMATIC B.Data.................................................................. 4/52
SIMATIC BATCH for WinCC.............................................. 4/108
SIMATIC Flat Panel PRO .................................................... 3/12
SIMATIC Flat Panels ......................................................... 5/130
SIMATIC HMI accessories.................................................. 2/96
SIMATIC HMI IPC477C....................................................... 5/63
SIMATIC HMI IPC477C bundles....................................... 5/110
SIMATIC HMI IPC477C PRO ................................................ 3/7
SIMATIC HMI IPC577C....................................................... 5/67
SIMATIC HMI IPC677C....................................................... 5/71
SIMATIC HMI IPC677C INOX ............................................. 3/22
SIMATIC HMI KP8/KP8F/32F................................................ 2/6
SIMATIC HMI Net Panel ..................................................... 6/14
SIMATIC HMI operator control and
monitoring systems .............................................................. 1/2
SIMATIC HMI Panel PC Ex ................................................. 3/26
SIMATIC HMI Thin Client Ex ............................................... 3/30
SIMATIC Industrial Flat Panel ........................................... 5/120
SIMATIC Industrial Flat Panel MT ..................................... 5/117
SIMATIC Industrial PC .......................................................... 5/2
SIMATIC Industrial Thin Client.......................................... 5/139
SIMATIC Information Server ............................................. 4/110
SIMATIC IPC BIOS Manager ............................................ 5/166
SIMATIC IPC CompactFlash ............................................ 5/155
SIMATIC IPC DiagMonitor ................................................ 5/164
SIMATIC IPC Image & Partition Creator ........................... 5/163
SIMATIC IPC Remote Manager ........................................ 5/165
SIMATIC IPC227D .............................................................. 5/30
SIMATIC IPC227D bundles .............................................. 5/102
SIMATIC IPC277D .............................................................. 5/53
SIMATIC IPC277D bundles .............................................. 5/108
S (continued)
SIMATIC IPC427C .............................................................. 5/39
SIMATIC IPC427C bundles .............................................. 5/104
SIMATIC IPC427D .............................................................. 5/36
SIMATIC IPC427D bundles .............................................. 5/103
SIMATIC IPC477D .............................................................. 5/58
SIMATIC IPC477D bundles .............................................. 5/109
SIMATIC IPC547D ................................................................ 5/7
SIMATIC IPC627C .............................................................. 5/44
SIMATIC IPC647C .............................................................. 5/13
SIMATIC IPC827C .............................................................. 5/47
SIMATIC IPC847C .............................................................. 5/20
SIMATIC KNX/EIB2S7......................................................... 6/22
SIMATIC Logon ....................................................... 4/37, 4/111
SIMATIC Logon for WinCC flexible..................................... 4/76
SIMATIC Maintenance Station.......................................... 4/112
SIMATIC Mobile Panel 177................................................. 2/45
SIMATIC Mobile Panel 277................................................. 2/52
SIMATIC Mobile Panel 277(F) IWLAN ................................ 2/57
SIMATIC mobile panel accessories ................................... 2/99
SIMATIC MP 377 PRO .......................................................... 3/4
SIMATIC Panel PC.............................................................. 5/50
SIMATIC Panel PC Remote Kit ......................................... 5/161
SIMATIC PC keyboard...................................................... 5/167
SIMATIC PC-based Automation ........................................... 1/8
SIMATIC PC-based controllers........................................... 5/76
SIMATIC powerrate ............................................................ 4/56
SIMATIC ProAgent............................................................ 4/161
SIMATIC ProAgent process diagnostics software............ 4/161
SIMATIC Process Historian............................................... 4/115
SIMATIC S5 ........................................................................ 2/87
SIMATIC S7 ............................................................... 2/77, 2/84
SIMATIC Thin Client.......................................................... 5/143
SIMATIC Thin Client PRO ................................................... 3/14
SIMATIC WinAC ODK......................................................... 5/90
SIMATIC WinAC RTX .......................................................... 5/77
SIMATIC WinAC RTX F ....................................................... 5/84
SIMATIC WinCC ................................................................. 4/88
SIMATIC WinCC (TIA Portal) Engineering ............................ 4/6
SIMATIC WinCC (TIA Portal) options.................................. 4/31
SIMATIC WinCC (TIA Portal) Runtime ................................ 4/12
SIMATIC WinCC flexible ES................................................ 4/60
SIMATIC WinCC flexible HMI system ................................. 4/59
SIMATIC WinCC flexible options ........................................ 4/71
SIMATIC WinCC flexible RT................................................ 4/64
SIMATIC WinCC Open Architecture................................. 4/146
Kap07_Anhang_en.book Seite 23 Montag, 5. August 2013 4:47 16
© Siemens AG 2013
Appendix
Index
7/24 Siemens ST 80 / ST PC · 2013
7
S (continued)
SIMATIC WinCC Open Architecture Add-ons .................. 4/155
SIMATIC WinCC options................................................... 4/107
SINEMA server ................................................................. 5/207
SIPLUS Basic Panels.......................................................... 2/24
SIPLUS Comfort Panels...................................................... 2/40
SIPLUS connection boxes.................................................. 2/73
SITOP power supplies...................................................... 5/170
SITOP UPS500P ............................................................... 5/178
SITOP UPS500S ............................................................... 5/177
SNMP OPC server............................................................ 5/206
Social Media, Mobile Media............................................... 7/11
SOFTNET for Industrial Ethernet ...................................... 5/196
SOFTNET for PROFIBUS.................................................. 5/227
SOFTNET PN IO ............................................................... 5/199
SOFTNET-IE RNA ............................................................. 5/198
Software for energy management...................................... 4/51
Software Licenses .............................................................. 7/19
Software packages for SIMATIC IPC and S7-mEC .......... 5/114
Solar systems ..................................................................... 6/28
Standards and approvals..................................................... 7/4
System components........................................................... 2/69
System components for Mobile Panels.............................. 2/69
System interfaces with WinCC (TIA Portal) ........................ 2/76
System interfaces with WinCC flexible............................... 2/83
T
Terminal boxes ................................................................... 2/70
Touch pen and touch stylus ............................................... 2/98
Transponder ....................................................................... 2/75
Turnkey products................................................................ 6/17
U
USB interfaces ................................................................... 3/20
W
WinCC add-ons and partner management...................... 4/144
WinCC Audit....................................................................... 4/36
WinCC Competence Centers............................................... 7/6
WinCC ControlDevelopment .............................................. 4/50
WinCC DataMonitor............................................................ 4/47
WinCC flexible /Archives.................................................... 4/73
WinCC flexible /Audit.......................................................... 4/75
WinCC flexible /ChangeControl.......................................... 4/72
WinCC flexible /OPC server ............................................... 4/85
WinCC flexible /ProAgent................................................... 4/87
WinCC flexible /Recipes..................................................... 4/74
WinCC flexible /Sm@rtAccess............................................ 4/78
WinCC flexible /Sm@rtService............................................ 4/82
WinCC Logging.................................................................. 4/34
WinCC Recipes .................................................................. 4/32
WinCC Runtime Advanced................................................. 4/13
WinCC Runtime Communication........................................ 4/25
WinCC Runtime Professional.............................................. 4/19
WinCC Server / WinCC Client............................................. 4/42
WinCC Sm@rtServer........................................................... 4/38
WinCC WebNavigator ........................................................ 4/44
WinCC/Calendar Scheduler ............................................. 4/116
WinCC/Central Archive Server (CAS)............................... 4/117
WinCC/ChangeControl & WinCC/Audit ............................ 4/118
WinCC/Connectivity Pack &
WinCC/Connectivity Station.............................................. 4/120
WinCC/DataMonitor.......................................................... 4/122
WinCC/DowntimeMonitor ................................................. 4/124
WinCC/Event Notifier........................................................ 4/126
WinCC/IndustrialDataBridge ............................................ 4/127
WinCC/IndustrialX ............................................................ 4/129
WinCC/Open Development Kit (ODK).............................. 4/130
WinCC/ProAgent .............................................................. 4/131
WinCC/Redundancy......................................................... 4/132
WinCC/Server................................................................... 4/133
WinCC/TeleControl ........................................................... 4/134
WinCC/User Archives....................................................... 4/138
WinCC/Web Navigator ..................................................... 4/139
Wind farms ......................................................................... 6/29
Y
Your machines and plant can do more
– with Industry Services ..................................................... 7/12
Kap07_Anhang_en.book Seite 24 Montag, 5. August 2013 4:47 16
© Siemens AG 2013
Appendix
Order No. Index
7/25
Siemens ST 80 / ST PC · 2013
2XV9
2XV9450 .................................................................. 4/105, 6/25
6AG1
6AG1124 ............................................................................ 2/43
6AG1500 .......................................................................... 2/109
6AG1647 ............................................................................ 2/25
6AG1671 ............................................................................ 2/73
6AG1931 ............................................................... 5/181, 5/182
6AG1972 ............................................................... 2/109, 5/181
6AG4
6AG4070 ............................................................................ 5/42
6AG4104 ................................................................... 5/10, 5/11
6AG4112 ................................................................... 5/17, 5/18
6AG4114 ................................................................... 5/22, 5/23
6AG4140 ............................................................................ 5/37
6AR1
6AR1403 .......................................... 5/148, 5/150, 5/150, 5/152
6AR1405 ................................................................ 5/148, 5/149
6AV2
6AV2107 ........................................ 4/18, 4/23, 4/24, 4/33, 4/35,
................................................ 4/36, 4/41, 4/43, 4/46, 4/49, 4/50
6AV2114 ........................................................................... 5/115
6AV2115 ........................................................................... 5/115
6AV2124 ....................................... 2/36, 2/129, 5/55, 5/128, 6/8
6AV2132 ............................................................................. 2/21
6AV2181 ............................................ 2/36, 2/117, 2/121, 2/133
6AV3
6AV3672 ........................................................................... 2/129
6AV3678 ........................................................................... 2/121
6AV3688 ............................................................. 2/10, 3/18, 6/8
6AV6
6AV6351 ................................................................ 4/152, 4/153
6AV6352 ............................... 4/153, 4/154, 4/158, 4/159, 4/160
6AV6361 ................................................................ 4/110, 4/115
6AV6371 .............................. 4/101, 4/102, 4/117, 4/119, 4/121,
.............................................. 4/123, 4/128, 4/129, 4/130, 4/131,
.................................... 4/132, 4/133, 4/138, 4/142, 4/143, 4/165
6AV6372 ................................... 4/55, 4/58, 4/116, 4/125, 4/126
6AV6381 ................................................................ 4/101, 4/102
6AV6382 ........................................................................... 5/115
6AV6574 .................... 2/102, 2/117, 2/121, 2/123, 2/129, 2/136
6AV6610 .................................................................... 4/62, 4/63
6AV6611 .................................................................... 4/62, 4/63
6AV6612 ........................................................... 4/10, 4/62, 4/63
6AV6613 ........................................................... 4/10, 4/62, 4/63
6AV6618 ... 4/69, 4/73, 4/74, 4/75, 4/81, 4/84, 4/86, 4/87, 4/165
6AV6623 ........................................................................... 5/115
6AV6642 ...................................................................... 6/8, 6/43
6AV6643 .................................................... 6/8, 6/23, 6/43, 6/45
6AV6644 ............................................. 3/6, 6/8, 6/43, 6/45, 6/51
6AV6 (Fortsetzung)
6AV6645 .............................. 2/51, 2/56, 2/67, 2/98, 2/129, 6/34
6AV6646 ................................................ 3/15, 5/142, 5/144, 6/9
6AV6647 ...................................................................... 2/21, 6/8
6AV6651 .................................................................... 2/21, 2/67
6AV6653 .................................................................. 3/15, 5/144
6AV6671 ............................... 2/51, 2/56, 2/72, 2/73, 2/75, 2/97,
.............................................. 2/100, 2/108, 2/117, 2/121, 2/123,
............................. 2/129, 2/134, 2/136, 2/138, 5/55, 5/144, 6/34
6AV6675 ........................................................................... 2/121
6AV6691 .............................. 2/51, 2/56, 2/67, 4/63, 4/69, 4/165
6AV7
6AV7200 .................................................................... 3/28, 3/31
6AV7240 .................................................................... 5/60, 5/61
6AV7426 ............................................................................. 6/16
6AV7461 ............................................................................. 6/38
6AV7466 ................................................................ 5/119, 5/137
6AV7476 ............................................................................. 6/47
6AV7486 ............................................................................. 6/47
6AV7671 ............... 5/65, 5/69, 5/74, 5/113, 5/128, 5/132, 5/161
6AV7672 ............................. 2/98, 2/129, 3/24, 5/55, 5/65, 5/69,
................................................. 5/74, 5/113, 5/128, 5/132, 5/155
6AV7674 ......................................... 3/16, 3/17, 3/18, 3/19, 3/20
6AV7675 .................................................................... 3/28, 3/31
6AV7860 ..................................................... 5/128, 5/132, 5/137
6AV7861 ........................................................... 3/13, 5/132, 6/9
6AV7862 ........................................................................... 5/137
6AV7863 ........................................................................... 5/128
6AV7872 ............................................................................. 6/43
6AV7881 ............................................................................. 5/55
6AV7883 ............................ 3/9, 3/10, 5/64, 5/111, 5/112, 5/113
6AV7884 ................................. 5/64, 5/111, 5/112, 5/113, 5/115
6AV7885 ............................................................................. 5/68
6AV789 ...................................................................... 3/23, 5/73
6AV7890 ............................................................................. 5/74
6AV7891 ............................................................................. 5/74
6AV7892 ............................................................................. 5/74
6AV7893 ............................................................................. 5/74
6AV7894 ............................................................................. 5/74
6AV9
6AV9681 ........................................................................... 4/142
6DL5
6DL5000 ........................................................................... 4/137
6DL5002 ........................................................................... 4/137
6DL5101 ........................................................................... 4/137
6ED1
6ED1056 ........................................................................... 2/117
6EP1
6EP1931 ................................................................ 5/181, 5/182
6EP1935 .......................................... 5/177, 5/182, 5/183, 5/184
Kap07_Anhang_en.book Seite 25 Montag, 5. August 2013 4:47 16
© Siemens AG 2013
Appendix
Order No. Index
7/26 Siemens ST 80 / ST PC · 2013
7
6ES7
6ES7193 ........................................................................... 2/108
6ES7272 ........................................................................... 2/136
6ES7623 ........................................................................... 2/138
6ES7647 ....................................... 5/33, 5/42, 5/45, 5/48, 5/207
6ES7648 ............................. 2/117, 3/24, 5/11, 5/18, 5/26, 5/33,
........................................... 5/42, 5/46, 5/49, 5/74, 5/106, 5/155,
................................... 5/160, 5/159, 5/160, 5/163, 5/164, 5/165,
................................................................................ 5/167, 5/169
6ES7657 ........................................................................... 4/109
6ES7658 ......................................................... 4/37, 4/77, 4/111
6ES7671 ......................................................... 5/82, 5/89, 5/115
6ES7675 ................................................................ 5/105, 5/106
6ES7677 .................................................................. 5/99, 5/100
6ES7806 ............................................................................. 5/90
6ES7820 ........................................................................... 5/204
6ES7840 ........................................................................... 4/114
6ES7900 ............ 3/24, 5/11, 5/18, 5/26, 5/46, 5/49, 5/74, 5/161
6ES7901 ....................................................... 2/109, 2/115, 4/70
6ES7972 ......................................................... 2/109, 4/30, 4/70
6GF6
6GF6220 ........................................................................... 5/134
6GK1
6GK1160 ............................................. 5/82, 5/89, 5/106, 5/187
6GK1161 .......................... 4/29, 4/70, 4/103, 4/104, 5/82, 5/89,
.......................................................... 5/188, 5/189, 5/191, 5/195
6GK1162 ................................ 4/29, 4/103, 5/192, 5/193, 5/195
6GK1500 .................. 2/109, 5/210, 5/212, 5/214, 5/216, 5/218,
.......................................................... 5/220, 5/222, 5/224, 5/226
6GK1551 .................................. 4/30, 4/70, 4/103, 4/105, 5/219
6GK1560 ............................................. 5/82, 5/89, 5/106, 5/209
6GK1561 ........................ 4/30, 4/70, 4/103, 4/104, 4/105, 5/82,
................................................ 5/89, 5/209, 5/211, 5/213, 5/215,
................................................................................ 5/217, 5/221
6GK1562 ........................ 4/30, 4/70, 4/103, 4/104, 4/105, 5/82,
............................................................ 5/89, 5/215, 5/217, 5/223
6GK1571 ............................................. 4/30, 4/70, 4/103, 5/225
6GK1704 .................... 4/29, 4/103, 5/104, 5/189, 5/190, 5/197,
................................... 5/200, 5/219, 5/220, 5/221, 5/222, 5/223,
............................................... 5/224, 5/225, 5/226, 5/227, 5/228
6GK1706 ........ 5/190, 5/197, 5/202, 5/204, 5/205, 5/206, 5/230
6GK1711 .......................................................................... 5/198
6GK1713 ...................... 4/30, 4/70, 4/104, 4/105, 5/210, 5/211,
................................... 5/212, 5/213, 5/214, 5/215, 5/216, 5/217,
........................................................................................... 5/218
6GK1716 ...................... 4/29, 4/70, 4/103, 4/104, 4/105, 5/191,
..................................................................... 5/192, 5/193, 5/195
6GK1781 .......................................................................... 5/207
6GK1901 ............................................................... 2/110, 2/111
6GK1905 ......................................... 5/210, 5/212, 5/214, 5/216
6GK1975 .......................................................................... 2/109
6GK5
6GK5204 .................................................... 5/187, 5/188, 5/198
6GK5784 ............................................................... 2/102, 2/103
6GK5786 ............................................................... 2/102, 2/103
6GK5788 ............................................................... 2/102, 2/103
6GK5791 .......................................................................... 2/103
6GT2
6GT2190 ........................................................................... 2/103
6GT2600 ........................................................................... 2/103
6XV1
6XV1440 .................................................................. 2/115, 6/34
6XV1830 ............................... 2/115, 5/210, 5/212, 5/214, 5/216
6XV1840 ................................................................ 2/110, 2/111
6XV1870 ................... 2/110, 2/111, 2/115, 5/187, 5/188, 5/190,
..................................................................... 5/191, 5/192, 5/193
6XV1871 ........................................................................... 2/111
A5E
A5E01064980 ..................................................................... 5/26
A5E02396171 ..................................................................... 5/18
A5E31477788 ..................................................................... 2/10
C794
C79459 ............................................................................. 5/220
W790
W79084 ............................................................................ 2/138
Kap07_Anhang_en.book Seite 26 Montag, 5. August 2013 4:47 16
© Siemens AG 2013
Appendix
Length key for connecting cables
7/27
Siemens ST 80 / ST PC · 2013
Length key for connecting cables
On connecting cables whose length is freely selectable accord-
ing to the following lists, the blanks (…) in the order no. must be
completed in accordance with the length codes given.
The different length keys must be taken into account here!
Other lengths on request.
Ordering example:
The 6XV1 404-0A… connecting cable must be 16 m long.
Multiplier 1.0 m (N) x length digit 16 (16) gives a length of 16 m.
The order no. supplement is N16.
This is entered in the blank spaces of the order no.
The complete order no. for the 16 m long connecting cable is
then
6XV1 404-0AN16
.
Length of the connecting cable =
Multiplier x length key Order no. supplement of the
connecting cable
6 X V
7 7 7 7
-
7 7 777
Multiplier
•0.01 m E
• 0.1 m H
• 1.0 m N
• 10.0 m T
•100.0 m U
Length digit
•10 1 0
•12 1 2
•15 1 5
•16 1 6
•20 2 0
•25 2 5
•32 3 2
•40 4 0
•50 5 0
•60 6 0
•63 6 3
•80 8 0
Kap07_Anhang_en.book Seite 27 Montag, 5. August 2013 4:47 16
© Siemens AG 2013
Appendix
Catalog improvement suggestions
Fax form
7/28 Siemens ST 80 / ST PC · 2013
7
To
Siemens AG
I IA AS S ID 2
ST 80 / ST PC 2013 / Ms. Beyer
Gleiwitzer Str. 555
90475 Nürnberg
Fax: +49 (911) 895-153114
E-mail: barbara.beyer@siemens.com
Your address
Your opinion is important to us!
Our catalog should be an important and frequently used
document. For this reason we are continuously endeavoring to
improve it.
A small request on our part to you:
Please take time to fill in the following form and fax it to us.
Thank You!
We invite you to grade our catalog on a point system from 1 (= good) to 6 (= poor):
Did you find any printing errors?
Name
Job
Company/Department
Street/No.
Postal code/City
Tel. No./Fax
E-mail address
Do the contents of the catalog live up to your expectations? Do the technical details meet your expectations?
Is the information easy to find? How would you assess the graphics and tables?
Can the texts be readily understood?
Kap07_Anhang_en.book Seite 28 Montag, 5. August 2013 4:47 16
© Siemens AG 2013
Appendix
Notes
7/29
Siemens ST 80 / ST PC · 2013
Kap07_Anhang_en.book Seite 29 Montag, 5. August 2013 4:47 16
© Siemens AG 2013
Appendix
Notes
7/30 Siemens ST 80 / ST PC · 2013
7
Kap07_Anhang_en.book Seite 30 Montag, 5. August 2013 4:47 16
© Siemens AG 2013
Appendix
Notes
7/31
Siemens ST 80 / ST PC · 2013
Kap07_Anhang_en.book Seite 31 Montag, 5. August 2013 4:47 16
© Siemens AG 2013
Appendix
Conditions of sale and delivery
7/32 Siemens ST 80 / ST PC · 2013
7
1. General Provisions
By using this catalog you can acquire hardware and software
products described therein from Siemens AG subject to the
following Terms and Conditions of Sale and Delivery (hereinafter
referred to as "T&C"). Please note that the scope, the quality and
the conditions for supplies and services, including software
products, by any Siemens entity having a registered office
outside Germany, shall be subject exclusively to the General
Terms and Conditions of the respective Siemens entity. The
following T&C apply exclusively for orders placed with Siemens
Aktiengesellschaft, Germany.
1.1 For customers with a seat or registered office in
Germany
For customers with a seat or registered office in Germany, the
following applies subordinate to the T&C:
the "General Terms of Payment"
1)
and,
for software products, the "General License Conditions for
Software Products for Automation and Drives for Customers
with a Seat or Registered Office in Germany"
1)
and,
for other supplies and services, the "General Conditions for
the Supply of Products and Services of the Electrical and
Electronics Industry"
1)
.
1.2 For customers with a seat or registered office outside
Germany
For customers with a seat or registered office outside Germany,
the following applies subordinate to the T&C:
the "General Terms of Payment"
1)
and,
for software products, the "General License Conditions for
Software Products for Automation and Drives for Customers
with a Seat or Registered Office outside of Germany"
1)
and
for other supplies and/or services, the "General Conditions for
Supplies of Siemens Industry for Customers with a Seat or
Registered Office outside of Germany"
1)
.
2. Prices
The prices are in
(Euro) ex point of delivery, exclusive of
packaging.
The sales tax (value added tax) is not included in the prices. It
shall be charged separately at the respective rate according to
the applicable statutory legal regulations.
Prices are subject to change without prior notice. We will charget
the prices valid at the time of delivery.
To compensate for variations in the price of raw materials (e.g.
silver, copper, aluminum, lead, gold, dysprosium and neodym),
surcharges are calculated on a daily basis using the so-called
metal factor for products containing these raw materials. A
surcharge for the respective raw material is calculated as a
supplement to the price of a product if the basic official price of
the raw material in question is exceeded.
The metal factor of a product indicates the basic official price
(for those raw materials concerned) as of which the surcharges
on the price of the product are applied, and with what method of
calculation.
An exact explanation of the metal factor can be downloaded at:
www.siemens.com/automation/salesmaterial-as/catalog/en/
terms_of_trade_en.pdf
To calculate the surcharge (except in the cases of dysprosium
and neodym), the official price from the day prior to that on which
the order was received or the release order was effected is used.
To calculate the surcharge applicable to dysprosium and
neodym ("rare earths"), the corresponding three-month basic
average price in the quarter prior to that in which the order was
received or the release order was effected is used with a one-
month buffer (details on the calculation can be found in the
explanation of the metal factor).
3. Additional Terms and Conditions
The dimensions are in mm. In Germany, according to the
German law on units in measuring technology, data in inches
apply only to devices for export.
Illustrations are not binding.
Insofar as there are no remarks on the individual pages of this
catalog - especially with regard to data, dimensions and weights
given - these are subject to change without prior notice.
4. Export regulations
We shall not be obligated to fulfill any agreement if such
fulfillment is prevented by any impediments arising out of
national or international foreign trade or customs requirements
or any embargoes and/or other sanctions.
Export of goods listed in this catalog may be subject to licensing
requirements. We will indicate in the delivery details whether
licenses are required under German, European and US export
lists. Goods labeled with "AL" not equal to "N" are subject to
European or German export authorization when being exported
out of the EU. Goods labeled with "ECCN" not equal to "N" are
subject to US re-export authorization.
The export indications can be viewed in advance in the
description of the respective goods on the Industry Mall, our
online catalog system. Only the export labels "AL" and "ECCN"
indicated on order confirmations, delivery notes and invoices
are authoritative.
Even without a label, or with label "AL:N" or "ECCN:N", authori-
zation may be required i .a. due to the final disposition and
intended use of goods.
If you transfer goods (hardware and/or software and/or
technology as well as corresponding documentation, regardless
of the mode of provision) delivered by us or works and services
(including all kinds of technical support) performed by us to a
third party worldwide, you must comply with all applicable
national and international (re-)export control regulations.
If required for the purpose of conducting export control checks,
you (upon request by us) shall promptly provide us with all infor-
mation pertaining to the particular end customer, final dispo-
sition and intended use of goods delivered by us respectively
works and services provided by us, as well as to any export
control restrictions existing in this relation.
The products listed in this catalog may be subject to
European/German and/or US export regulations. Any export
requiring approval is therefore subject to authorization by the
relevant authorities.
Errors excepted and subject to change without prior notice.
1) The text of the Terms and Conditions of Siemens AG can be
downloaded at
www.siemens.com/automation/salesmaterial-as/catalog/en/
terms_of_trade_en.pdf
Kap07_Anhang_en.book Seite 32 Montag, 5. August 2013 4:47 16
© Siemens AG 2013
Catalogs
Industry Automation, Drive Technologies and Low-Voltage Power Distribution
Further information can be obtained from our branch offices
listed at www.siemens.com/automation/partner
System Solutions
Interactive Catalog on DVD Catalog
Products for Automation and Drives and
Low Voltage Power Distribution CA 01
Building Control
GAMMA Building Control ET G1
Drive Systems
SINAMICS G130 Drive Converter Chassis Units
SINAMICS G150 Drive Converter Cabinet Units D11
SINAMICS GM150, SINAMICS SM150
Medium-Voltage Converters D12
ROBICON Perfect Harmony
Medium-Voltage Air-Cooled Drives
Germany Edition
D15.1
Digital: SINAMICS G180
Converters Compact Units, Cabinet Systems,
Cabinet Units Air-Cooled and Liquid-Cooled
D18.1
SINAMICS S120 Chassis Format Units and
Cabinet Modules
SINAMICS S150 Converter Cabinet Units
D21.3
SINAMICS DCM Converter Units D23.1
SINAMICS DCM Cabinet D23.2
SINAMICS and Motors for Single-Axis Drives D31
Three-Phase Induction Motors SIMOTICS HV,
SIMOTICS TN
Series H-compact
Series H-compact PLUS
D84.1
Asynchronous Motors Standardline D86.1
Synchronous Motors with Permanent-Magnet
Technology, HT-direct D86.2
DC Motors DA 12
SIMOREG DC MASTER 6RA70 Digital Chassis
Converters DA 21.1
SIMOREG K 6RA22 Analog Chassis Converters DA 21.2
Digital: SIMOREG DC MASTER 6RM70 Digital
Converter Cabinet Units DA 22
SIMOVERT PM Modular Converter Systems DA 45
SIEMOSYN Motors DA 48
MICROMASTER 420/430/440 Inverters DA 51.2
MICROMASTER 411/COMBIMASTER 411 DA 51.3
SIMOVERT MASTERDRIVES Vector Control DA 65.10
SIMOVERT MASTERDRIVES Motion Control DA 65.11
Synchronous and asynchronous servomotors for
SIMOVERT MASTERDRIVES DA 65.3
SIMODRIVE 611 universal and POSMO DA 65.4
Note: Additional catalogs on SIMODRIVE or SINAMICS
drive systems and SIMOTICS motors with SINUMERIK
and SIMOTION can be found under Motion Control
Low-Voltage Three-Phase-Motors
SIMOTICS Low-Voltage Motors D81.1
MOTOX Geared Motors D87.1
SIMOGEAR Geared Motors MD 50.1
SIMOGEAR Gearboxes with adapter MD 50.11
Mechanical Driving Machines
FLENDER Standard Couplings MD 10.1
FLENDER High Performance Couplings MD 10.2
FLENDER SIG Standard industrial gear unit MD 30.1
FLENDER SIP Standard industrial planetary gear units MD 31.1
Process Instrumentation and Analytics
Field Instruments for Process Automation FI 01
Digital: SIPART Controllers and Software MP 31
Products for Weighing Technology WT 10
Digital: Process Analytical Instruments PA 01
Digital: Process Analytics,
Components for the System Integration PA 11
Digital: These catalogs are only available as a PDF
and/or as an e-book.
Low-Voltage Power Distribution and
Electrical Installation Technology
Catalog
SENTRON Protection, Switching, Measuring and
Monitoring Devices LV 10.1
SIVACON · ALPHA Switchboards and
Distribution Systems LV 10.2
Standards-Compliant Components for
Photovoltaic Plants LV 11
3WT Air Circuit Breakers up to 4000 A LV 35
3VT Molded Case Circuit Breakers up to 1600 A LV 36
Digital: SIVACON System Cubicles, System Lighting
and System Air-Conditioning LV 50
Digital: ALPHA Distribution Systems LV 51
ALPHA FIX Terminal Blocks LV 52
SIVACON S4 Power Distribution Boards LV 56
SIVACON 8PS Busbar Trunking Systems LV 70
Motion Control
SINUMERIK & SIMODRIVE
Automation Systems for Machine Tools NC 60
SINUMERIK & SINAMICS
Equipment for Machine Tools NC 61
SINUMERIK 840D sl Type 1B
Equipment for Machine Tools NC 62
SINUMERIK 808D, SINAMICS V60 and G120,
SIMOTICS 1FL5 and 1LE1 NC 81.1
SINUMERIK 828D BASIC T/BASIC M,
SINAMICS S120 Combi, 1FK7 and 1PH8 motors NC 82
SIMOTION, SINAMICS S120 & SIMOTICS
Equipment for Production Machines PM 21
Drive and Control Components for Cranes CR 1
Power Supply and System Cabling
Power supply SITOP KT 10.1
Safety Integrated
Safety Technology for Factory Automation SI 10
SIMATIC HMI/PC-based Automation
Human Machine Interface Systems/
PC-based Automation ST 80/
ST PC
SIMATIC Ident
Industrial Identification Systems ID 10
SIMATIC Industrial Automation Systems
Products for Totally Integrated Automation ST 70
SIMATIC PCS 7 Process Control System ST PCS 7
Add-ons for the SIMATIC PCS 7
Process Control System ST PCS 7.1
Digital: Migration solutions with the SIMATIC PCS 7
Process Control System ST PCS 7.2
SIMATIC NET
Industrial Communication IK PI
SINVERT Photovoltaics
Inverters and Components for Photovoltaic Installations RE 10
SIRIUS Industrial Controls
SIRIUS Industrial Controls IC 10
Information and Download Center
PDF versions of the catalogs are available on the Internet at:
www.siemens.com/industry/infocenter
There you’ll find additional catalogs in other languages.
Please note the section “Downloading catalogs” on page
“Online services” in the appendix of this catalog.
U3_IADT-LP_en_4f.fm Seite 2 Dienstag, 6. August 2013 11:38 11
© Siemens AG 2013
The information provided in this catalog contains descriptions or
characteristics of performance which in case of actual use do not
always apply as described or which may change as a result of further
development of the products. An obligation to provide the respective
characteristics shall only exist if expressly agreed in the terms of
contract. Availability and technical specifications are subject to
change without notice.
All product designations may be trademarks or product names
of Siemens AG or supplier companies whose use by third parties
for their own purposes could violate the rights of the owners.
Siemens AG
Industry Sector
Industrial Automation Systems
Postfach 48 48
90026 NÜRNBERG
GERMANY
Subject to change without prior notice
Order No. E86060-K4680-A101-C1-7600
MQ.R0.R1.0000.04.3.01 / Dispo 07900
KG 0813 3. AUM 672 En / IWI TSTE
Printed in Germany
© Siemens AG 2013
www.siemens.com/automation
SO_Umschlag_KG_ST80_STPC_2013_en.indd 2SO_Umschlag_KG_ST80_STPC_2013_en.indd 2 05.08.2013 13:48:1805.08.2013 13:48:18
© Siemens AG 2013

Navigation menu