P RDF Version A.1
2014-09-04
: Pdf 100190-Attachment 100190-Attachment 783166 Batch7 unilog
Open the PDF directly: View PDF .
Page Count: 36
Download | |
Open PDF In Browser | View PDF |
RDF Series Direct-Fired Makeup Air Heater IMPORTANT 1. Always include complete heater model and serial number so that any specification change can be considered for parts shipment. It can save time and expense. 2. Specifications are subject to change without notice. 3. We reserve the right to substitute functional replacements. 4. Order either by Kit or Component Part No. Replacement Parts Form RZ-NA P-RDF (Version A) Obsoletes Form RGM 740 (Version A) and P-RDF ® APPLIES TO: Index by Page No. Amplifier Belts Blowers Burners Cabinet Parts Circuit Analyzer Board Contactor Dampers Disconnect Switch Drives ECO Device Electrical Compartment Illustration Filter Sections Filters Firestat Flame Sensor Freezestat Fuseholder and Fuses Gas T rain Controls Outside Air Inlet Hoods Ignition System Limit Controls Maxitrol System Components Mirror Modulating Gas Controls Motors (Blower) Motors (Damper) Potentiometer Pressure Switches (Air) Pressure Switches (Gas) Rating Plate Regulators Relays Remote Console Roof Curbs Serial No. Sheaves Starters T emperature Sensor T ransformer Valves 13 23-32 22 16-16 33-36 4-5 6 17-18 21 23-32 4-5 3 35 35 4-5 14, 15 4-5 4-5 11-12 35 14-15 4-5 13 16 13-14 6-8 17-18 4, 6, 20 4-5 12 1 11 4 20 36 2 23-32 6-10 13 4-5 11-12 Rating Plate and Serial No. REZNOR MERCER, PA. USA 16137 ANSI Z83.18A-2001 DIRECT-FIRED INDUSTRIAL AIR HEATER FOR INDUSTRIAL/COMMERCIAL USE ONLY FOR EITHER INDOOR OR OUTDOOR INSTALLATION MODEL { } SERIAL # A GAS TYPE { } MOTOR HP { B VOLTAGE { } PHASE { D MAX TOTAL INPUT AMPS FOR THE UNIT { WIRING DIAGRAM NUMBER: { } P } C E F } } 60 HZ UNIT IS EQUIPPED FOR { G } SCFM AGAINST { H } IN WC ESP WITH A MAX DISCH TEMP OF { Q } oF AND A MAX TEMP RISE OF { Z } oF AND CANNOT BE USED BELOW -40 oF THIS HEATER HAS BEEN DESIGNED TO OPERATE AT A MINIMUM { } CFM OF VENTILATION AIR TO PROPERLY DILUTE ITS I COMBUSTION PRODUCTS BASED ON A MINIMUM ROOM AIR TEMPERATURE OF 55 oF, A MINIMUM OUTDOOR TEMPERATURE OF -40 oF, AND A MAXIMUM DISCHARGE TEMPERATURE OF { Q } oF. SEE INSTALLATION INSTRUCTIONS FOR OTHER LIMITATIONS FOR RE-CIRCULATION APPLICATIONS. MAXIMUM INPUT RATING { J MINIMUM INPUT RATING { K NORMAL MANIFOLD PRESS. { L MIN GAS INLET PRESS. FOR BURN. ADJ. { MAX PERMISSIBLE GAS SUPPLY PRESS. { MIN PRESSURE DROP ACROSS BURNER MAX PRESSURE DROP ACROSS BURNER } } } M N 0.25 0.75 BTU/HR BTU/HR IN WC } IN WC } PSI IN WC IN WC CLEARANCES TO COMBUSTIBLES: TOP, BOTTOM, AND SIDE OPPOSITE CONTROLS - 1 INCH FOR SERVICE ON CONTROL SIDE OF UNIT - WIDTH OF UNIT INSTALL UNITS IN ACCORDANCE TO THE MOST RECENT STAND. ANSI/NFPA 409 IF INSTALLED IN AIRCRAFT HANGERS STAND. ANSI/NFPA 88A IF INSTALLED IN PARKING STRUCTURES STAND. ANSI/NFPA 88B IF INSTALLED IN REPAIR GARAGES ADDITIONAL REFERENCES Forms: • • • • • • Model RDF Installation Form I-RDF, Model RDF Operation/Maintenance/Service Form O-ADF/DV/RDF Installation Form I-OPT-C, Roof Curb Installation Instructions Parts Form P-GC, Gas Conversion Parts Form P-VALVES, Serial No., Gas Valves, and Maxitrol Gas Controls Instruction Form CP-RDF-IGN, Conversion to Hot Surface Ignition Website: www.RezSpec.com (Forms are available to download.) Rating Plate Codes: A = Model No. B = Gas Type (Nat or LP) C = Motor HP D = Volt E = Phase F = Maximum Total Input Amps for Unit G = SCFM H = ESP I = CFM J = Maximum Input K = Minimum Input L = Manifold Presssure M = Minimum Inlet Pressure N = Maximum Supply Pressure P = Wiring Diamgram No. Q = Maximum Discharge Temperature Z = Maximum Temperature Rise °F Form P-RDF, Page 1 Serial No. Rating Plate and Serial No. (cont'd) Example: ANH 61 K2 N 1 2 3 4 40297 CA 5 MV7 6 7 Codes: 1 = Date of manufacture (see chart on page 2) 2 = Type of pilot 3 = Type of valve 4 = Type of gas (N= Natural; L= Propane) 5 = Consecutive number 6 = Type of air control (CA=Constant Air Volume; VA=Variable Air Volume; RA=Recirculation Air) 7 = Type of Maxitrol gas control (MV7=Maxitrol System 14; MV8=Maxitrol System 14A; MV9=Maxitrol System 44; MVB=Maxitrol System 94; MVC=with Maxitrol A200 Conditioner; MVD=Maxitrol System 14E; MVE-Maxitrol System 44E-21; MVF-Maxitrol System 44ER-21) First Element of the Serial Number - Date of Manufacture Year 1984 1985 1986 1987 1988 1989 1990 1991 1992 1993 1994 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 2006 2007 2008 2009 2010 2011 2012 2013 2014 2015 Jan AJA AKA ALA AMA ANA AOA APA AQA ARA ASA ATA AUA AVA AWA AXA AYA AZA BAA BBA BCA BDA BEA BFA BGA BHA BIA BJA BKA BLA BMA BNA BOA Form P-RDF, Page 2 Feb AJB AKB ALB AMB ANB AOB APB AQB ARB ASB ATB AUB AVB AWB AXB AYB AZB BAB BBB BCB BDB` BEB BFB BGB BHB BIB BJB BKB BLB BMB BNB BOB Mar AJC AKC ALC AMC ANC AOC APC AQC ARC ASC ATC AUC AVC AWC AXC AYC AZC BAC BBC BCC BDC BEC BFC BGC BHC BIC BJC BKC BLC BMC BNC BOC Apr AJD AKD ALD AMD AND AOD APD AQD ARD ASD ATD AUD AVD AWD AXD AYD AZD BAD BBD BCD BDD BED BFD BGD BHD BID BJD BKD BLD BMD BND BOD May AJE AKE ALE AME ANE AOE APE AQE ARE ASE ATE AUE AVE AWE AXE AYE AZE BAE BBE BCE BDE BEE BFE BGE BHE BIE BJE BKE BLE BME BNE BOE June AJF AKF ALF AMF ANF AOE APF AQF ARF ASF ATF AUF AVF AWF AXF AYF AZF BAF BBF BCF BDF BEF BFF BGF BHF BIF BJF BKF BLF BMF BNF BOF July AJG AKG ALG AMG ANG AOG APG AQG ARG ASG ATG AUG AVG AWG AXG AYG AZG BAG BBG BCG BDG BEG BFG BGG BHG BIG BJG BKG BLG BMG BNG BOG Aug AJH AKH ALH AMH ANH AOH APH AQH ARH ASH ATH AUH AVH AWH AXH AYH AZH BAH BBH BCH BDH BEH BFH BGH BHH BIH BJH BKH BLH BMH BNH BOH Sept AJI AKI ALI AMI ANI AOI API AQI ARI ASI ATI AUI AVI AWI AXI AYI AZI BAI BBI BCI BDI BEI BFI BGI BHI BII BJI BKI BLI BMI BNI BOI Oct AJJ AKJ ALJ AMJ ANJ AOJ APJ AQJ ARJ ASJ ATJ AUJ AVJ AWJ AXJ AYJ AZJ BAJ BBJ BCJ BDJ BEJ BFJ BGJ BHJ BIJ BJJ BKJ BLJ BMJ BNJ BOJ Nov AJK AKK ALK AMK ANK AOK APK AQK ARK ASK ATK AUK AVK AWK AXK AYK AZK BAK BBK BCK BDK BEK BFK BGK BHK BIK BJK BKK BLK BMK BNK BOK Dec AJL AKL ALL AML ANL AOL APL AQL ARL ASL ATL AUL AVL AWL AXL AYL AZL BAL BBL BCL BDL BEL BFL BGL BHL BIL BJL BKL BLL BML BNL BOL Electrical Control Compartment Typical Component Locations See below and the following pages for P/N's and illustrations. NOTE: Illustration shows approximate locations of controls on RDF Series 3 systems. Manufacture of Series 3 system began in 9/03. RDF systems manufactured prior to Series 3 have similar controls but control locations are different. Because this product has experienced ongoing development, always provide complete model and serial number when inquiring about or ordering replacement parts. Control Relays Time Delay Relay Outside Air Cutoff (high ambient limit control) 24-volt Terminals Return Air Damper Motor Maxitrol Amplifier or Signal Conditioner Circuit Board Service Switches High Optional Dirty Filter Pressure Switch Transformer Ignition Module 24-Volt Terminals Status Lights Bypass Damper Motor Motor Starter Low Standard Pressure Switches Relay for Optional 2-Speed Starter Relay Line Voltage Terminals Model RDF Series 3 Control Compartment Control Relays Contactor or Starter Electrical Box Dirty Filter Switch Ignitor Module Transformer Circuit Analyzer Amplifier or Signal Conditioner High and Low Pressure Switches Gas Train/ Manifold Form P-RDF, Page 3 Electrical Components CODE 1A 1B 2A 2B 3 4A 4B 5 6A 6B 7 8 9 10 11 12 13 14 15 16 17 18A 18B 19 20A 20B 21 22 22A 22B 23 24 25 26A 26B 27A 27B 28 29 30 31 32 33 34 Description RBM Relay, SP-ST, Hamilton Standard #84-20102-101 Codes 1A&B are Hamilton Standard #134-20102-101 24V Coil interchangeable. Codes 2A&B are RBM Relay, SP-DT, Hamilton Standard #84-20103-301 Products Unltd 9400-04-Q180 interchangeable. 24V Coil Time Delay Relay (Low Fire), 24V Coil, Thermodisc #F12S20, Style 305005 Codes 4A&B are RBM Relay, SP-ST, Hamilton Standard #84-50202-101 Hamilton Standard #134-50202-101 interchangeable. 120V Coil Time Delay Relay (for freezestat bypass), T&B Agastst #VTM1ULA RBM Relay, SP-DT, Hamilton Standard #84-50203-301 Codes 6A&B are Hamilton Standard #134-50203-301 120V Coil interchangeable. Prepurge Time Delay Relay, 24V Coil, Thermodisc #12S20 Relay, 24V Coil, Essex #91-102006-1300 Manual Reset Limit, Thermodisc 330545, L150 Automatic Limit, L135, Thermodisc #60T11-312616 Outside Air Cutoff (High Ambient Limit) & Freezestat, J/C #A19AAF-12C Flame Safety Limit (ECO), Opens 306°F, Thermodisc #G4AP0200152C Firestat, Honeywell #L4029E1029, 200°F Spark Generator, 120V, Honeywell #Q624A1014 Low Air Pressure Switch, IS2-0233-5275 for RDF Series 3 Low Air Pressure Switch Kit replaces P/N 86986, #FS4197-166 or PPS10175-3043 High Air Pressure Switch, IS2-0233-5273 for RDF Series 3 High Air Pressure Switch Kit replaces P/N 86987, #FS4197-164 or PPS10175-3041 Plastic Tee for Air Pressure Tubing, 3/16", 1/16" I.D. Yellow Plastic Tubing for air pressure switch, 3/16" O.D. x 14" Clear Plastic Tubing for Air Pressure Switch, 3/16" O.D. x 3 ft Bushing and Insect Screen for Sensing Probes (not illustrated) Air Pressure Switch, IS2-0233-5274 for RDF Series 3 Air Pressure Switch Kit replaces P/N 87250, #FS4197-165 or PPS10175-3042 Air Pressure Switch, IS2-0233-5276 for RDF Series 3 Air Pressure Switch Kit replaces P/N 87249, #FS4197-171 or PPS10175-3044 Contactor, Furnace 42AF15AJ, 24V (used with Option BM80 and BM81 manifold) Diagnostic Circuit Analyzer Board Replacement Bulb for Circuit Analyzer Board, RDF Series 3 Replacement Light for Circuit Analyzer Board (Option BS2 prior to RDF Series 3) Replacement Relay for Code 22, SKMP-2C-24AC Terminal Block, #KT3 Terminal Block Adapter Convenience Outlet Receptacle, Hubbell #GF5362 (separate electrical supply) Dirty Filter Pressure Switch, Tri-Delta #AP4434, set at .3" w.c. Clear Plastic Tubing for Dirty Filter Pressure Switch, 3/16" O.D. x 112" Fuseholder, 24V, Wesco #S257A57G01 Fuseholder, Buss Model HTB-481 Fuses - See descriptions and list of P/N's on page 5. Transformer - See descriptions and list of P/N's on page 5. DPDT System Switch, Winter/Off/Summer, Cutler Hammer 7561K6 SPDT Switch (service switch), Cutler Hammer 7505K6 Null Pressure Switch, .01" - .20" w.c., Dwyer #1640-0 Potentiometer, Honeywell 112894FA Photohelic Pressure Sensor in Options AR36 & AR37, 3000-00-N24 Vac CODE 1B Relay, P/N 98118 CODE 2B Relay, P/N 103317 CODE 5 Time Delay Relay (Freezestat), P/N 89661 CODE 6 Relay, P/N 103318 Form P-RDF, Page 4 Location Control Compartment Control Compartment P/N 14747 98118 18549 103317 89254 86982 103319 89661 90205 103318 52887 110656 82610 86979 126170 82414 42782 86974 207178 193806 207176 193807 87482 122855 102401 96794 207177 193809 207179 193808 203935 151263 125189 101889 151271 144972 144973 96912 105507 179302 38635 60241 Space (Console) Control Compartment Heated Space Space / Remote Console Remote 101900 101901 88052 16110 158893 Control Compartment Control Compartment Control Compartment Control Compartment Control Compartment Control Compartment Control Compartment Control Compartment Blower Discharge Blower Discharge Control Compartment Gas Train Compartment Blower Discharge Control Compartment Control Compartment Control Compartment Control Compartment Control Compartment Control Compartment Control Compartment Control Compartment Control Compartment Control Compartment & Remote Console Control Compartment Control Compartment CODE 3 Time Delay Relay (Low Fire), P/N 89254 (On units mfgd prior to 3/96) CODE 7 Prepurge Time Delay Relay, P/N 52887 CODE 4B Relay, P/N 103319 CODE 8 Relay, P/N 110656 CODE 9 Limit Switch, P/N 82610 Reset Button CODE 10 - Limit, P/N 86979 CODE 11, - Adjustable Outside Air Cutoff Control and Freezestat, P/N 126170 (Replaces P/N 16108) (Automatic Reset) CODE 12 - ECO Limit, P/N 82414 CODE 13 Firestat, P/N 42782 Grommet Clamp, P/N 131993; Cable Clamp, P/N 132065 CODE 14 Spark Generator, P/N 86974 CODE 15 - Low Air Pressure Switch, P/N 207178 (On units mfgd prior to 3/96) CODE 17 - Tee for Air Pressure Tubing, P/N 87482 CODE 16 - High Air Pressure Switch, P/N 207176 CODE 20A - Air Pressure Switch, P/N 207177 Replace pressure switch P/N 86986 with Kit P/N 193806. CODE 20B - Air Pressure Switch, P/N 207179 CODE 21 - Contactor, Furnas 42AF15AJ, 24V, (used with Option BM80 and BM81 manifold, P/N 203935 CODE 18A - Clear Plastic Tubing, P/N 102401 (3') Replace pressure Replace pressure switch switch P/N 86987 CODE 18B - Yellow Plastic P/N 87250 with Kit P/N with Kit P/N 193807. Tubing, P/N 122855 (14") 193809. CODE 22 - Circuit Analyzer Board, P/N 151263 (Std beginning with RDF Series 3. Option BS2 prior to Series 3.) CODE 23 Terminal Block, P/N 144972 CODE 22A, Replacement Lights for Circuit Analyzer Board - P/N 125189 Series 3; prior to Series 3, P/N 101889 CODE 22B, Replacement Relay for Board, P/N 151271 Fuseholders and Fuses CODE 27A Fuseholder, P/N 38635 CODE 27B - Fuseholder, P/N 60241 (used with spark ignition) CODE 29 - Transformers 40VA 200-500 VA Replace pressure switch P/N 87249 with Kit P/N 193808. CODE 25 Convenience Outlet Receptacle, P/N 96912 CODE 24 Terminal Block Adapter, P/N 144973 CODE 28 Fuses Description 2.5 Amp, #3210 (spark ignition) Bussman FRN-R15, 230/1 Bussman FRN-R30, 208/230/3 Bussman FRN-R10, 208/3 Bussman FRN-R7, 230/3 Bussman FRN-R25, 208/3 Bussman FRN-R60 Bussman FRN-R50 Bussman FRN-R90 Bussman FRN-R150 CODE 26A - Dirty Filter Pressure Switch, P/N 105507 (replaces P/N 102773) CODE 26B - Clear Plastic Tubing, 3/16", P/N 179302 P/N 61542 14667 31892 89265 16207 45054 31895 87957 89931 91077 Description Bussman FRN-R175 Bussman FRS-R3.5, 460/3 Bussman FRS-R8, 460/3 Bussman FRS-R5, 460/3 Bussman FRS-R15, 460/3 Bussman FRS25 Bussman FRS-R40 8 Amp, Fusetron 3AG-8 (hot surface ignition) 5 Amp, Fusetron MDL 3AG P/N 91595 89266 89268 89267 87638 31891 89936 38636 90335 Volts In Volts Out VA Manufacturer's No. Reznor P/N 115 24 200 Hevi-Duty #2223018T00 38634 (used with hot surface ignition) 115 24 40 Basler #BE141650-WAA 103055 (Used with spark igntion) (2 required to replace P/N 61806) 208/230 24 40 Basler #BE21539001 103497 (2 required to replace P/N 61807) 208 110 500 Hevi-Duty #2227003T00 86998 230/460 24 200 Siemens MT0200JX24 39095 230/460 110 500 Hevi-Duty #2227001T00 86997 460 24 40 Basler #BE23975001 103498 (2 required to replace P/N 61808) Form P-RDF, Page 5 Electrical Components (cont'd) CODE 32 Potentiometer, P/N 16011 (remote damper motor control in Options AR 19 and 22) CODE 30 - DPDT System Switch, P/N 101900 (winter/off/ summer) CODE 32 - Null Pressure Switch, P/N 88052 (remote damper motor control in Air Control Options AR 20 and 23) CODE 31 DPDT System Switch, P/N 101901 (service switch) CODE 34 - Photohelic Pressure Sensor, P/N 158893 (remote damper motor control in Air Control Options AR 36 and 37) CODE 35 - Sampling Tube only, P/N 159714 Blower Motors, Contactor, and Starters CODE 36 CODE 35 - BLOWER MOTOR CODE 37 Motors in the table below that do not have a CODE 36 contactor listed do not have internal overload protection and MUST be used with the CODE 37 motor starter and starter overload. If a contactor is listed, motor may be used with either the contactor or the optional starter. CODE 36 - Replacement Contactor (Option AN2) Motor contactor, P/N 119625, Mfr #42AF35AJ-24V coil Contactor Starter (24V) CODE 37 - Replacement Starter (24V) & Overload (Option AN10) Overload (Located in the electrical compartment; see location on page 3.) Type OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN HP 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 3/4 3/4 1 1 1 1 1 1 1 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2 2 2 2 2 2 2 3 3 3 3 3 3 CODE 35 -Motor P/N Model No. BF2054 102627 BF2054 102627 BF2054 102627 H880 159183 H880 159183 H880 159183 H991 202089 312P629 93548 312P629 93548 312P629 93548 312P696 36951 312P696 36951 312P696 36951 H992 202090 C523 13685 C523 13685 C523 13685 H882 36580 H882 36580 H882 36580 E1006 158175 C621 194202 C621 194202 C621 194202 H884 115859 H884 115859 H884 115859 E1007 158162 RB1204A 202581 RB1204A 202581 RB1204A 202581 H886 159327 H886 159327 H886 159327 E1008 158176 B735 111560 B735 111560 H845 159185 H845 159185 H845 159185 H954 120019 Form P-RDF, Page 6 Frame 56Z 56Z 56Z LA56 LA56 LA56 H56 B56 B56 B56 D56 D56 D56 H56 H56 H56 H56 F56 F56 F56 N143T 56 56 56 UA56 UA56 UA56 R145T 56 56 56 56HZ 56HZ 56HZ P145T L56 L56 P56HZ P56HZ P56HZ N56HZ fla 8.8 5.1 4.4 2.5 3.0 1.5 0.9 11.0 6.3 5.5 2.9 2.6 1.3 1.0 13.0 7.5 6.5 3.7 3.2 1.6 1.1 15.0 7.8 7.5 5.6 5.0 2.8 1.6 24.6 12.3 12.3 7.0 6.6 3.5 2.1 13.7 12.4 9.0 8.6 4.3 3.6 When ordering a replacement IEC starter or overload, check the manufacturer's number on both parts. If the number is different than that listed, both components must be replaced. IEC Starter (contactor) and overload are mounted on rail, P/N 111387. If Model RDF was manufactured prior to 1996, check to see if the IEC starter is line voltage or 24 volt. If line voltage, select replacement starter on pages 9-10. If the motor has a NEMA starter (units mfgd before 1991), see the replacement parts on page 10. Shaft Volt ph 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 7/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 7/8" 7/8" 7/8" 7/8" 7/8" 7/8" 7/8" 7/8" 5/8" 5/8" 7/8" 7/8" 7/8" 7/8" 120 208 240 208 240 480 575 120 208 240 208 240 480 575 120 208 240 208 240 480 575 120 208 240 208 240 480 575 120 208 240 208 240 480 575 208 230 208 240 480 575 1 1 1 3 3 3 3 1 1 1 3 3 3 3 1 1 1 3 3 3 3 1 1 1 3 3 3 3 1 1 1 3 3 3 3 1 1 3 3 3 3 Service Power Efficiency CODE 37 - Starter (24V) Factor Factor Mfr No. P/N % 1.15 CL00A310T-1 151275 1.15 CL00A310T-1 151275 1.15 CL00A310T-1 151275 1.25 CL00A310T-1 151275 1.25 CL00A310T-1 151275 1.25 CL00A310T-1 151275 1.25 CL00A310T-1 151275 1.25 CL01A310T-1 151276 1.25 CL00A310T-1 151275 1.25 CL00A310T-1 151275 1.25 CL00A310T-1 151275 1.25 CL00A310T-1 151275 1.25 CL00A310T-1 151275 1.25 CL00A310T-1 151275 1.25 CL01A310T-1 151276 1.25 CL00A310T-1 151275 1.25 CL00A310T-1 151275 1.15 79% CL00A310T-1 151275 1.15 79% CL00A310T-1 151275 1.15 79% CL00A310T-1 151275 1.15 82.50% CL00A310T-1 151275 1.2 86.4 77.20% CL01A310T-1 151276 1.2 86.4 77.20% CL00A310T-1 151275 1.2 86.4 77.20% CL00A310T-1 151275 1.15 66.4 78.60% CL00A310T-1 151275 1.15 66.4 78.60% CL00A310T-1 151275 1.15 66.4 78.60% CL00A310T-1 151275 1.15 85.3 84.00% CL00A310T-1 151275 CL04A310M-1 151279 CL01A310T-1 151276 CL01A310T-1 151276 1.15 67 79% CL00A310T-1 151275 1.15 67 79% CL00A310T-1 151275 1.15 67 79% CL00A310T-1 151275 1.15 86 84.00% CL00A310T-1 151275 1.15 CL01A310T-1 151276 1.15 CL01A310T-1 151276 1.15 CL00A310T-1 151275 1.15 CL00A310T-1 151275 1.15 CL00A310T-1 151275 1.15 80.3 83.80% CL00A310T-1 151275 min 8.00 4.00 4.00 1.80 2.50 1.30 0.65 10.00 5.50 4.00 2.50 2.50 1.00 0.65 10.00 5.50 5.50 2.50 2.50 1.30 1.00 10.00 5.50 5.50 4.00 4.00 2.50 1.30 21.00 10.00 10.00 5.50 5.50 2.50 1.80 10.00 10.00 8.00 8.00 4.00 2.50 Starter Overload max GE # P/N 12.00 RTA1-N 151193 6.30 RTA1-L 151191 6.30 RTA1-L 151191 2.70 RTA1-J 151189 4.10 RTA1-K 151190 1.90 RTA1-H 151188 1.10 RTA1-F 151186 16.00 RTA1-P 151194 8.50 RTA1-M 151192 6.30 RTA1-L 151191 4.10 RTA1-K 151190 4.10 RTA1-K 151190 1.50 RTA1-G 151187 1.10 RTA1-F 151186 16.00 RTA1-P 151194 8.50 RTA1-M 151192 8.50 RTA1-M 151192 4.10 RTA1-K 151190 4.10 RTA1-K 151190 1.90 RTA1-H 151188 1.50 RTA1-G 151187 16.00 RTA1-P 151194 8.50 RTA1-M 151192 8.50 RTA1-M 151192 6.30 RTA1-L 151191 6.30 RTA1-L 151191 4.10 RTA1-K 151190 1.90 RTA1-H 151188 26.00 RTA1-U 151198 16.00 RTA1-P 151194 16.00 RTA1-P 151194 8.50 RTA1-M 151192 8.50 RTA1-M 151192 4.10 RTA1-K 151190 2.70 RTA1-J 151189 16.00 RTA1-P 151194 16.00 RTA1-P 151194 12.00 RTA1-N 151193 12.00 RTA1-N 151193 6.30 RTA1-L 151191 4.10 RTA1-K 151190 CODE 36 - Contactor Mfr No. P/N 42AF35AJ-24V 119625 42AF35AJ-24V 119625 42AF35AJ-24V 119625 42AF35AJ-24V 119625 42AF35AJ-24V 119625 42AF35AJ-24V 119625 ============ === 42AF35AJ-24V 119625 42AF35AJ-24V 119625 42AF35AJ-24V 119625 42AF35AJ-24V 119625 42AF35AJ-24V 119625 42AF35AJ-24V 119625 ============ === 42AF35AJ-24V 119625 42AF35AJ-24V 119625 42AF35AJ-24V 119625 42AF35AJ-24V 119625 42AF35AJ-24V 119625 42AF35AJ-24V 119625 ============ === 42AF35AJ-24V 119625 42AF35AJ-24V 119625 42AF35AJ-24V 119625 42AF35AJ-24V 119625 42AF35AJ-24V 119625 42AF35AJ-24V 119625 ============ === 42AF35AJ-24V 119625 42AF35AJ-24V 119625 42AF35AJ-24V 119625 42AF35AJ-24V 119625 42AF35AJ-24V 119625 42AF35AJ-24V 119625 ============ === ============ === ============ === 42AF35AJ-24V 119625 42AF35AJ-24V 119625 42AF35AJ-24V 119625 ============ === Blower Motors, Contactor, and Starters (cont'd) Type OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC HP 5 5 5 5 5 5 7.5 7.5 7.5 7.5 7.5 7.5 10 10 10 10 10 10 15 15 15 15 20 20 20 20 25 25 25 25 30 30 30 30 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 3/4 3/4 1 1 1 1 1 1 1 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2 2 2 2 2 2 3 3 3 3 3 3 5 5 5 5 5 CODE 35 - Motor P/N Model No. V211 111562 V211 111562 196033 113371 196033 113371 196033 113371 H956 120020 V305 105828 V305 105828 E302 105854 E300 105855 E300 105855 E324 158164 V303 105830 V303 105830 E303 105857 E301 105858 E301 105858 E325 158163 142287 B-FM2513T-8 142288 BALD-FM2513T 142288 BALD-FM2513T 142289 B-EFM2513T-5 142295 B-FM2515T-8 142296 BAL-FM2515T 142296 BAL-FM2515T 142297 B-FM2515T-5 E545-F2 159021 E546-F2 159022 E546-F2 159022 E594-F2 159023 E547-F2 159024 E548-F2 159025 E548-F2 159025 E595-F2 159026 C613 159184 C613 159184 C613 159184 H274 16077 H274 16077 H274 16077 H276 105568 F353 115860 F353 115860 F353 159184 H580 20371 H580 20371 H580 20371 H461 105569 159105 174993 159105 174993 159105 174993 H524 16080 H524 16080 H524 16080 H525 105570 311P402 94347 311P402 94347 311P402 94347 H535 101286 H535 101286 H535 101286 E127 105665 K200 105572 L3516TM 205881 E166 158165 E166 158165 E166 158165 E169 158166 K222 111564 K222 111564 B - M3559T 159330 B - M3559T 159330 B - M3559T 159330 B-M3559T-5 111571 K223 111567 E241 155048 E241 155048 E241 155048 E273 158170 Frame L184T L184T Y56HZ Y56HZ Y56HZ Y56HZ S215T S215T F213T 213T 213T S213T S215T S215T F215T 215T 215T S215T 254T 254T 254T 254T 256T 256T 256T 256T S284T S284T S284T S284T S286T S286T S286T S286T J56 J56 J56 H56 H56 H56 J56 F56 F56 F56 KA56 KA56 KA56 L56 L56 L56 L56 J56 J56 J56 H56 TK56H TK56H TK56H L56H L56H L56H M145T F182T F182T 145T 145T 145T 145T F184T F184T 145T 145T 145T 145T F184T 184T 184T 184T 184T fla 28.3 25.6 13.4 13.2 6.6 5.4 35.4 32.0 22.5 19.4 9.7 7.8 42.0 38.0 31.0 26.0 13.0 10.4 43.1 39.0 19.5 16.0 58.7 53.0 26.5 21.2 69.8 60.6 30.3 24.3 78.0 75.0 37.5 30.0 7.2 3.5 3.6 2.3 2.0 1.0 0.7 11.0 5.4 5.5 2.0 2.2 1.1 0.8 12.0 6.2 6.0 3.3 3.4 1.7 1.4 16.4 9.5 8.2 4.3 4.4 2.2 1.6 24 8.3 7.0 5.8 2.9 2.3 30.0 15.0 7.9 7.2 3.6 3 20.2 16 12 6 4.8 Shaft Volt ph 1-1/8" 1-1/8" 7/8" 7/8" 7/8" 7/8" 1-3/8" 1-3/8" 1-3/8" 1-3/8" 1-3/8" 1-3/8" 1-3/8" 1-3/8" 1-3/8" 1-3/8" 1-3/8" 1-3/8" 1-5/8" 1-5/8" 1-5/8" 1-5/8" 1-5/8" 1-5/8" 1-5/8" 1-5/8" 1-7/8" 1-7/8" 1-7/8" 1-7/8" 1-7/8" 1-7/8" 1-7/8" 1-7/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 5/8" 7/8" 1-1/8" 7/8" 7/8" 7/8" 7/8" 7/8" 1-1/8" 1-1/8" 7/8" 7/8" 7/8" 7/8" 1-1/8" 1-1/8" 1-1/8" 1-1/8" 1-1/8" 208 240 208 240 480 575 208 230 208 240 480 575 208 230 208 240 480 575 208 240 480 575 208 240 480 575 208 240 480 575 208 240 480 575 120 208 240 208 240 480 575 120 208 240 208 240 480 575 120 208 240 208 240 480 575 120 208 240 208 240 480 575 120 240 208 240 480 575 120 240 208 240 480 575 240 208 240 480 575 1 1 3 3 3 3 1 1 3 3 3 3 1 1 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 1 1 1 3 3 3 3 1 1 1 3 3 3 3 1 1 1 3 3 3 3 1 1 1 3 3 3 3 1 1 3 3 3 3 1 1 3 3 3 3 1 3 3 3 3 Service Power Efficiency CODE 37 - Starter (24V) % Factor Factor Mfr No. P/N CL04A310M-1 151279 CL04A310M-1 151279 1.15 87.2 85% CL01A310T-1 151276 1.15 87.2 85% CL01A310T-1 151276 1.15 87.2 85% CL00A310T-1 151275 1.15 85.9 85.30% CL00A310T-1 151275 CL06A311M-1 203687 CL06A311M-1 203687 CL04A310M-1 151279 CL25A310T-1 151278 CL00A310T-1 151275 CL00A310T-1 151275 CL06A311M-1 203687 CL06A311M-1 203687 CL04A310M-1 151279 CL04A310M-1 151279 CL01A310T-1 151276 CL01A310T-1 151276 CL06A311M-1 203687 CL06A311M-1 203687 CL25A310T-1 151278 CL02A310T-1 151277 1.15 80 88.50% CL07A311M-1 203793 1.15 81 88.50% CL07A311M-1 203793 1.15 81 88.50% CL04A310M-1 151279 1.15 80 88.50% CL25A310T-1 151278 1.15 84.1 91.70% CL09A311M-1 203794 1.15 84.1 91.70% CL07A311M-1 203793 1.15 84.1 91.70% CL04A310M-1 151279 1.15 84.1 91.70% CL04A310M-1 151279 1.15 81 92.40% CL09A311M-1 203794 1.15 81 92.40% CL09A311M-1 203794 1.15 81 92.40% CL06A311M-1 203687 1.15 81 92.40% CL04A310M-1 151279 CL00A310T-1 151275 CL00A310T-1 151275 CL00A310T-1 151275 1 59.5 74.80% CL00A310T-1 151275 1 59.5 74.80% CL00A310T-1 151275 1 59.5 74.80% CL00A310T-1 151275 1.15 76.4 77% CL00A310T-1 151275 CL01A310T-1 151276 CL00A310T-1 151275 CL00A310T-1 151275 1 73.5 81.10% CL00A310T-1 151275 1 73.5 81.10% CL00A310T-1 151275 1 73.5 81.10% CL00A310T-1 151275 1.15 78.3 82% CL00A310T-1 151275 CL01A310T-1 151276 CL00A310T-1 151275 CL00A310T-1 151275 1 74.4 80.20% CL00A310T-1 151275 1 74.4 80.20% CL00A310T-1 151275 1 74.4 80.20% CL00A310T-1 151275 1.15 71.6 80.40% CL00A310T-1 151275 CL02A310T-1 151277 CL00A310T-1 151275 CL00A310T-1 151275 1 80.9 82.40% CL00A310T-1 151275 1 80.9 82.40% CL00A310T-1 151275 1 80.9 82.40% CL00A310T-1 151275 1.15 85.7 84% CL00A310T-1 151275 CL04A310M-1 151279 1.15 99 78% CL00A310T-1 151275 CL00A310T-1 151275 CL00A310T-1 151275 CL00A310T-1 151275 CL00A310T-1 151275 CL04A310M-1 151279 CL02A310T-1 151277 CL00A310T-1 151275 CL00A310T-1 151275 CL00A310T-1 151275 CL00A310T-1 151275 CL25A310T-1 151278 CL02A310T-1 151277 CL01A310T-1 151276 CL00A310T-1 151275 CL00A310T-1 151275 min 25.00 25.00 10.00 10.00 5.50 4.00 30.00 30.00 21.00 17.50 8.00 5.50 30.00 30.00 25.00 25.00 10.00 10.00 42.00 30.00 17.50 14.50 54.00 42.00 25.00 17.50 64.00 54.00 25.00 21.00 64.00 64.00 30.00 25.00 5.50 2.50 2.50 1.80 1.80 0.65 0.65 10.00 4.00 4.00 1.80 1.80 1.00 0.65 10.00 4.00 4.00 2.50 2.50 1.30 1.00 14.50 8.00 8.00 4.00 4.00 1.80 1.30 21.00 5.50 5.50 4.00 2.50 1.90 25.00 14.50 5.50 5.50 2.50 2.50 17.50 14.50 10.00 4.00 4.00 Starter Overload max GE # P/N 32.00 RTA1-V 151199 32.00 RTA1-V 151199 16.00 RTA1-P 151194 16.00 RTA1-P 151194 8.50 RTA1-M 151192 6.30 RTA1-L 151191 43.00 RTA2-E 151206 43.00 RTA2-E 151206 26.00 RTA1-U 151198 22.00 RTA1-T 151197 12.00 RTA1-N 151193 8.50 RTA1-M 151192 43.00 RTA2-E 151206 43.00 RTA2-E 151206 32.00 RTA1-V 151199 32.00 RTA1-V 151199 16.00 RTA1-P 151194 16.00 RTA1-P 151194 55.00 RTA2-G 151202 43.00 RTA2-E 151206 22.00 RTA1-T 151197 18.00 RTA1-S 151196 65.00 RTA2-H 151203 55.00 RTA2-G 151202 32.00 RTA1-V 151199 22.00 RTA1-T 151197 82.00 RTA2-J 151204 65.00 RTA2-H 151203 32.00 RTA1-V 151199 26.00 RTA1-U 151198 82.00 RT2-J 151204 82.00 RT2-J 151204 43.00 RTA2-E 151206 32.00 RTA1-V 151199 8.50 RTA1-M 151192 4.10 RTA1-K 151190 4.10 RTA1-K 151190 2.70 RTA1-J 151189 2.70 RTA1-J 151189 1.10 RTA1-F 151186 1.10 RTA1-F 151186 16.00 RTA1-P 151194 6.30 RTA1-L 151191 6.30 RTA1-L 151191 2.70 RTA1-J 151189 2.70 RTA1-J 151189 1.50 RTA1-G 151187 1.10 RTA1-F 151186 16.00 RTA1-P 151194 6.30 RTA1-L 151191 6.30 RTA1-L 151191 4.10 RTA1-K 151190 4.10 RTA1-K 151190 1.90 RTA1-H 151188 1.50 RTA1-G 151187 18.00 RTA1-S 151196 12.00 RTA1-N 151193 12.00 RTA1-N 151193 6.30 RTA1-L 151191 6.30 RTA1-L 151191 2.70 RTA1-J 151189 1.90 RTA1-H 151188 26.00 RTA1-U 151198 8.50 RTA1-M 151192 8.50 RTA1-M 151192 6.30 RTA1-L 151191 4.10 RTA1-K 151190 2.70 RTA1-J 151189 32.00 RTA1-V 151199 18.00 RTA1-S 151196 8.50 RTA1-N 151192 8.50 RTA1-N 151192 4.10 RTA1-K 151190 4.10 RTA1-K 151190 22.00 RTA1-T 151197 18.00 RTA1-S 151196 16.00 RTA1-P 151194 6.30 RTA1-L 151191 6.30 RTA1-L 151191 CODE 36 - Contactor Mfr No. P/N ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === 42AF35AJ-24V 119625 42AF35AJ-24V 119625 42AF35AJ-24V 119625 42AF35AJ-24V 119625 42AF35AJ-24V 119625 42AF35AJ-24V 119625 ============ === 42AF35AJ-24V 119625 42AF35AJ-24V 119625 42AF35AJ-24V 119625 42AF35AJ-24V 119625 42AF35AJ-24V 119625 42AF35AJ-24V 119625 ============ === 42AF35AJ-24V 119625 42AF35AJ-24V 119625 42AF35AJ-24V 119625 42AF35AJ-24V 119625 42AF35AJ-24V 119625 42AF35AJ-24V 119625 ============ === 42AF35AJ-24V 119625 42AF35AJ-24V 119625 42AF35AJ-24V 119625 42AF35AJ-24V 119625 42AF35AJ-24V 119625 42AF35AJ-24V 119625 ============ === ============ === 42AF35AJ-24V 119625 ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === (continued) Form P-RDF, Page 7 Blower Motors, Contactor, and Starters (cont'd) Type TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC EE EE EE EE EE EE EE EE EE EE EE EE EE EE EE EE EE EE EE EE EE EE EE EE EE EE EE EE EE EE EE EE EE EE EE EE HP 7.5 7.5 7.5 7.5 7.5 10 10 10 10 10 15 15 15 20 20 20 1 1 1 1 1 1/2 1 1/2 1 1/2 1 1/2 2 2 2 2 3 3 3 3 5 5 5 5 7 1/2 7 1/2 7 1/2 7 1/2 10 10 10 10 15 15 15 15 20 20 20 20 CODE 35 - Motor P/N Model No. K305 105842 E356 158171 E356 158171 E356 158171 E364 158172 K313 105846 E357 158173 E357 158173 E357 158173 E365 158174 142443 BAL-FM2333T 142443 BAL-FM2333T B-FM2333-5 142444 142301 BAL-FM2334T 142301 BAL-FM2334T 142302 B-FM2334T-5 E103 105659 E1015 159328 E1015 159328 E1006 158175 E104 105662 E1016 159329 E1016 159329 E1007 158162 E105 105664 E1017 159027 E1017 159027 E1008 158176 159186 B-35L405S489G3 B-EM3158T 159028 B-EM3158T 159028 159030 B-35L405S709G1 E204 159029 E204 159029 E204 159029 111602 BAL-M3613T-5 E316 159331 E317 159332 E317 159332 E324 158164 E318 159333 E397 159334 E397 159334 E325 158163 142440 B-EFM2513T-8 142441 B-EFM2513T 142441 B-EFM2513T 142289 B-EFM2513T-5 C-E452-F2 159187 142299 B-EFM2515T 142299 B-EFM2515T 142300 B-EFM2515T-5 Frame F215T 213T 213T 213T 213T 215T 215T 215T 215T 215T 254T 254T 254T 256T 256T 256T N143T 143T 143T N143T P145T 145T 145T R145T P145T 145T 145T P145T 145T 145T 145T 145T H182T H182T H182T 184T D213T D213T D213T S213T H215T H215T H215T S215T 254T 254T 254T 254T S256T 256T 256T 256T fla 34 24 19 9.5 7.6 39 30 26 13 9.6 38 19 15 52 26 20.6 3.1 2.7 1.4 1.1 4.5 3.9 2.0 1.6 6.0 5.8 2.9 2.1 8.3 7.4 3.7 3.0 13.9 11.6 5.8 4.8 22.3 19.4 9.7 7.8 27.8 24.2 12.1 10.4 41.5 36.0 18.0 16 57.0 48.0 24.0 19.2 Shaft Volt ph 1-3/8" 1-3/8" 1-3/8" 1-3/8" 1-3/8" 1-3/8" 1-3/8" 1-3/8" 1-3/8" 1-3/8" 1-5/8" 1-5/8" 1-5/8" 1-5/8" 1-5/8" 1-5/8" 7/8" 7/8" 7/8" 7/8" 7/8" 7/8" 7/8" 7/8" 7/8" 7/8" 7/8" 7/8" 7/8" 7/8" 7/8" 7/8" 1-1/8" 1-1/8" 1-1/8" 1-1/8" 1-3/8" 1-3/8" 1-3/8" 1-3/8" 1-3/8" 1-3/8" 1-3/8" 1-3/8" 1-5/8" 1-5/8" 1-5/8" 1-5/8" 1-5/8" 1-5/8" 1-5/8" 1-5/8" 240 208 240 480 575 240 208 240 480 575 240 480 575 240 480 575 208 240 480 575 208 240 480 575 208 240 480 575 208 240 480 575 208 240 480 575 208 240 480 575 208 240 480 575 208 240 480 575 208 240 480 575 1 3 3 3 3 1 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 Service Power Efficiency CODE 37 - Starter (24V) Factor Factor Mfr No. P/N % CL06A311M-1 203687 CL04A310M-1 151279 CL25A310T-1 151278 CL00A310T-1 151275 CL00A310T-1 151275 CL06A311M-1 203687 CL04A310M-1 151279 CL04A310M-1 151279 CL02A310T-1 151277 CL00A310T-1 151275 1.15 82 90.20% CL06A311M-1 203687 1.15 82 90.20% CL25A310T-1 151278 1.15 82 90.20% CL02A310T-1 151277 1.15 81 89.50% CL07A311M-1 203793 1.15 81 89.50% CL04A310M-1 151279 1.15 81 89.50% CL25A310T-1 151278 CL00A310T-1 151275 CL00A310T-1 151275 CL00A310T-1 151275 CL00A310T-1 151275 CL00A310T-1 151275 CL00A310T-1 151275 CL00A310T-1 151275 CL00A310T-1 151275 CL00A310T-1 151275 CL00A310T-1 151275 CL00A310T-1 151275 CL00A310T-1 151275 CL00A310T-1 151275 CL00A310T-1 151275 CL00A310T-1 151275 CL00A310T-1 151275 CL02A310T-1 151277 CL01A310T-1 151276 CL00A310T-1 151275 CL00A310T-1 151275 CL04A310M-1 151279 CL25A310T-1 151278 CL00A310T-1 151275 CL00A310T-1 151275 CL04A310M-1 151279 CL04A310M-1 151279 CL01A310T-1 151276 CL01A310T-1 151276 1.15 84 92.40% CL06A311M-1 203687 1.15 84 92.40% CL06A311M-1 203687 1.15 84 92.40% CL25A310T-1 151278 1.15 84 92.40% CL02A310T-1 151277 1.15 84 93.60% CL07A311M-1 203793 1.15 84 93.00% CL07A311M-1 203793 1.15 84 93.00% CL04A310M-1 151279 1.15 84 93.00% CL25A310T-1 151278 min 30.00 21.00 17.50 8.00 5.50 30.00 25.00 21.00 10.00 8.00 30.00 17.50 10.00 42.00 25.00 17.50 2.50 2.50 1.00 1.00 4.00 2.50 1.90 1.30 4.00 4.00 2.50 1.90 8.00 5.50 2.50 2.50 10.00 10.00 5.50 4.00 21.00 17.50 8.00 5.50 25.00 21.00 10.00 10.00 30.00 30.00 17.50 10.00 54.00 42.00 21.00 17.50 Starter Overload max GE # P/N 43.00 RTA2-E 151206 26.00 RTA1-U 151198 22.00 RTA1-T 151197 12.00 RTA1-N 151193 8.50 RTA1-N 151192 43.00 RTA2-E 151206 32.00 RTA1-V 151199 26.00 RTA1-U 151198 16.00 RTA1-P 151194 12.00 RTA1-N 151193 43.00 RTA2-E 151206 22.00 RTA1-T 151197 16.00 RTA1-P 151194 55.00 RTA2-G 151202 32.00 RTA1-V 151199 22.00 RTA1-T 151197 4.10 RTA1-K 151190 4.10 RTA1-K 151190 1.50 RTA1-G 151187 1.50 RTA1-G 151187 6.30 RTA1-L 151191 4.10 RTA1-K 151190 2.70 RTA1-J 151189 1.90 RTA1-H 151188 6.30 RTA1-L 151191 6.30 RTA1-L 151191 4.10 RTA1-K 151190 2.70 RTA1-J 151189 12.00 RTA1-N 151193 8.50 RTA1-N 151192 4.10 RTA1-K 151190 4.10 RTA1-K 151190 16.00 RTA1-P 151194 16.00 RTA1-P 151194 8.50 RTA1-M 151192 6.30 RTA1-L 151191 26.00 RTA1-U 151198 22.00 RTA1-T 151197 12.00 RTA1-N 151193 8.50 RTA1-N 151192 32.00 RTA1-V 151199 26.00 RTA1-U 151198 16.00 RTA1-P 151194 16.00 RTA1-P 151194 43.00 RTA2-E 151206 43.00 RTA2-E 151206 22.00 RTA1-T 151197 16.00 RTA1-P 151194 65.00 RTA2-H 151203 55.00 RTA2-G 151202 26.00 RTA1-U 151198 22.00 RTA1-T 151197 CODE 36 - Contactor Mfr No. P/N ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === ============ === 24 LB1A-C 120 LB1A-J 208 LB1A-L 230 LB1A-S 460 LB1A-U 575 LB1A-Y Form P-RDF, Page 8 GE # 24 120 208 230 460 575 LB3A-C LB3A-J LB3A-L LB3A-S LB3A-U LB3A-Y For Use with Reznor Contactors P/N Beginning with GE# 151286 151287 151288 CL04; CL45 151289 151290 151291 For Use with Reznor Contactors GE # P/N Beginning with GE# 208 LB4A-L 151292 CL06; CL07; 230 LB4A-S 151293 CL08; CL09 460 LB4A-U 151294 Voltage GE # For Use with Reznor Contactors P/N Beginning with GE# 151280 151281 151282 CL00; CL01; 151283 CL02; CL25 151284 151285 Voltage Voltage CODE 38 - Replacement Holding Coils for IEC Starters Replacement Line Voltage IEC Starters for RDF units manufactured before 1996 Type OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN OPEN HP 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 3/4 1 1 1 1 1 1 1 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2 2 2 2 2 2 2 3 3 3 3 3 3 3 3 3 5 5 5 5 5 5 7.5 7.5 7.5 7.5 7.5 7.5 10 10 10 10 10 10 15 15 15 15 20 20 20 20 25 25 25 25 30 30 30 30 Motor P/N 102627 102627 102627 159183 159183 159183 93548 93548 93548 36951 36951 36951 13685 13685 13685 36580 36580 36580 158175 194202 194202 194202 115859 115859 115859 158162 202581 202581 202581 159327 159327 159327 158176 111560 111560 159185 159185 159185 120019 152002 152002 152002 111562 111562 113371 113371 113371 120020 105828 105828 105854 105855 105855 158164 105830 105830 105857 105858 105858 158163 142287 142288 142288 142289 142295 142296 142296 142297 159021 159022 159022 159023 159024 159025 159025 159026 CODE 39 - Starter (line voltage) and Overloads volt ph Mfg No. P/N min max GE # P/N 120 1 CL00A310T-J 151146 8.00 12.00 RTA1-N 151193 208 1 CL00A310T-L 151150 4.00 6.30 RTA1-L 151191 240 1 CL00A310T-S 151147 4.00 6.30 RTA1-L 151191 208 3 CL00A310T-L 151150 1.90 2.70 RTA1-J 151189 240 3 CL00A310T-S 151147 2.50 4.10 RTA1-K 151190 480 3 CL00A310T-U 151148 1.30 1.90 RTA1-H 151188 120 1 CL01A310T-J 151151 10.00 16.00 RTA1-P 151194 208 1 CL00A310T-L 151150 5.50 8.50 RTA1-M 151192 240 1 CL00A310T-S 151147 4.00 6.30 RTA1-L 151191 208 3 CL00A310T-L 151150 2.50 4.10 RTA1-K 151190 240 3 CL00A310T-S 151147 2.50 4.10 RTA1-K 151190 480 3 CL00A310T-U 151148 1.00 1.50 RTA1-G 151187 120 1 CL01A310T-J 151151 10.00 16.00 RTA1-P 151194 208 1 CL00A310T-L 151150 5.50 8.50 RTA1-M 151192 240 1 CL00A310T-S 151147 5.50 8.50 RTA1-M 151192 208 3 CL00A310T-L 151150 2.50 4.10 RTA1-K 151190 240 3 CL00A310T-S 151147 2.50 4.10 RTA1-K 151190 480 3 CL00A310T-U 151148 1.30 1.90 RTA1-H 151188 575 3 CL00A310T-Y 151149 1.00 1.50 RTA1-G 151187 120 1 CL02A310T-J 151156 10.00 16.00 RTA1-P 151194 208 1 CL00A310T-L 151150 5.50 8.50 RTA1-M 151192 240 1 CL00A310T-S 151147 5.50 8.50 RTA1-M 151192 208 3 CL00A310T-L 151150 4.00 6.30 RTA1-L 151191 240 3 CL00A310T-S 151147 4.00 6.30 RTA1-L 151191 480 3 CL00A310T-U 151148 2.50 4.10 RTA1-K 151190 575 3 CL00A310T-Y 151149 1.30 1.90 RTA1-H 151188 120 1 CL25A310T-J 151160 17.50 22.00 RTA1-T 151197 208 1 CL01A310T-L 151155 8.00 12.00 RTA1-N 151193 240 1 CL01A310T-S 151152 8.00 12.00 RTA1-N 151193 208 3 CL00A310T-L 151150 5.50 8.50 RTA1-M 151192 240 3 CL00A310T-S 151147 5.50 8.50 RTA1-M 151192 480 3 CL00A310T-U 151148 2.50 4.10 RTA1-K 151190 575 3 CL00A310T-Y 151149 1.90 2.70 RTA1-J 151189 208 1 CL02A310T-L 151159 10.00 16.00 RTA1-P 151194 240 1 CL01A310T-S 151152 10.00 16.00 RTA1-P 151194 208 3 CL00A310T-L 151150 8.00 12.00 RTA1-N 151193 240 3 CL00A310T-S 151147 8.00 12.00 RTA1-N 151193 480 3 CL00A310T-U 151148 4.00 6.30 RTA1-L 151191 575 3 CL00A310T-Y 151149 2.50 4.10 RTA1-K 151190 208 3 ====== ====== 8.00 12.00 RTA1-N 151193 240 3 ====== ====== 5.50 8.50 RTA1-M 151192 480 3 ====== ====== 2.50 4.10 RTA1-K 151190 208 1 CL04A310M-L 151169 25.00 32.00 RTA1-V 151199 240 1 CL04A310M-S 151166 25.00 32.00 RTA1-V 151199 208 3 CL01A310T-L 151155 10.00 16.00 RTA1-P 151194 240 3 CL01A310T-S 151152 10.00 16.00 RTA1-P 151194 480 3 CL00A310T-U 151148 5.50 8.50 RTA1-M 151192 575 3 CL00A310T-Y 151149 4.00 6.30 RTA1-L 151191 208 1 CL06A311M-L 151173 30.00 43.00 RTA2-E 151206 240 1 CL45A310M-S 151170 25.00 32.00 RTA1-V 151199 208 3 CL25A310T-L 151164 21.00 26.00 RTA1-U 151198 240 3 CL25A310T-S 151161 17.50 22.00 RTA1-T 151197 480 3 CL01A310T-U 151153 8.00 12.00 RTA1-N 151193 575 3 CL00A310T-Y 151149 5.50 8.50 RTA1-M 151192 208 1 CL06A311M-L 151173 30.00 43.00 RTA2-E 151206 240 1 CL06A311M-S 151172 30.00 43.00 RTA2-E 151206 208 3 CL04A310M-L 151169 25.00 32.00 RTA1-V 151199 240 3 CL04A310M-S 151166 25.00 32.00 RTA1-V 151199 480 3 CL01A310T-U 151153 10.00 16.00 RTA1-P 151194 575 3 CL01A310T-Y 151154 10.00 16.00 RTA1-P 151194 208 3 CL06A311M-L 151173 42.00 55.00 RTA2-G 151202 240 3 CL06A311M-S 151172 30.00 43.00 RTA2-E 151206 480 3 CL25A310T-U 151162 17.50 22.00 RTA1-T 151197 575 3 CL02A310T-Y 151158 14.50 18.00 RTA1-S 151196 208 3 CL07A311M-L 151176 54.00 65.00 RTA2-H 151203 240 3 CL07A311M-S 151175 42.00 55.00 RTA2-G 151202 480 3 CL04A310M-U 151167 25.00 32.00 RTA1-V 151199 575 3 CL25A310T-Y 151163 17.50 22.00 RTA1-T 151197 208 3 CL09A311M-L 151179 64.00 82.00 RTA2-J 151204 240 3 CL08A311M-S 151177 54.00 65.00 RTA2-H 151203 480 3 CL45A310M-U 151171 25.00 32.00 RTA1-V 151199 575 3 CL04A310M-Y 151168 21.00 26.00 RTA1-U 151198 208 3 CL09A311M-L 151179 64.00 82.00 RT2-J 151204 240 3 CL09A311M-S 151178 64.00 82.00 RT2-J 151204 480 3 CL06A311M-U 151174 30.00 43.00 RTA2-E 151206 575 3 CL04A310M-Y 119852 25.00 32.00 RTA1-V 151199 Type TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC TEFC HP 1/2 1/2 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 3/4 3/4 1 1 1 1 1 1 1 1.5 1.5 1.5 1.5 1.5 1.5 1.5 2 2 2 2 2 2 3 3 3 3 3 3 5 5 5 5 5 7.5 7.5 7.5 7.5 7.5 10 10 10 10 10 15 15 15 20 20 20 25 25 25 25 30 30 30 30 Motor P/N 159184 159184 159184 16077 16077 16077 105568 115860 115860 115860 20371 20371 20371 105569 174993 174993 174993 16080 16080 16080 105570 94347 94347 94347 101286 101286 101286 105665 105572 105572 158165 158165 158165 158166 111564 111564 159330 159330 159330 111571 111567 155048 155048 155048 158170 105842 158171 158171 158171 158172 105846 158173 158173 158173 158174 142443 142443 142444 142301 142301 142302 165321 165321 165321 165322 165323 165323 165323 165324 CODE 39 - Starter (line voltage) and Overloads volt ph Mfg No. P/N min max GE # P/N 120 1 CL00A310T-J 151146 5.50 8.50 RTA1-M 151192 208 1 CL00A310T-L 151150 2.50 4.10 RTA1-K 151190 240 1 CL00A310T-S 151147 2.50 4.10 RTA1-K 151190 208 3 CL00A310T-L 151150 1.90 2.70 RTA1-J 151189 240 3 CL00A310T-S 151147 1.90 2.70 RTA1-J 151189 480 3 CL00A310T-U 151148 0.65 1.10 RTA1-F 151186 575 3 CL00A310T-Y 151149 0.65 0.90 RTA1-F 151186 120 1 CL01A310T-J 151151 10.00 16.00 RTA1-P 151194 208 1 CL00A310T-L 151150 4.00 6.30 RTA1-L 151191 240 1 CL00A310T-S 151147 4.00 6.30 RTA1-L 151191 208 3 CL00A310T-L 151150 1.90 2.70 RTA1-J 151189 240 3 CL00A310T-S 151147 1.90 2.70 RTA1-J 151189 480 3 CL00A310T-U 151148 1.00 1.50 RTA1-G 151187 575 3 CL00A310T-Y 151149 0.65 1.10 RTA1-F 151186 120 1 CL01A310T-J 151151 10.00 16.00 RTA1-P 151194 208 1 CL00A310T-S 151147 5.50 8.50 RTA1-M 151192 240 1 CL00A310T-S 151147 5.50 8.50 RTA1-M 151192 208 3 CL00A310T-L 151150 2.50 4.10 RTA1-K 151190 240 3 CL00A310T-S 151147 2.50 4.10 RTA1-K 151190 480 3 CL00A310T-U 151148 1.30 1.90 RTA1-H 151188 575 3 CL00A310T-Y 151149 1.00 1.50 RTA1-G 151187 120 1 CL02A310T-J 151156 14.50 18.00 RTA1-S 151196 208 1 CL00A310T-L 151150 8.00 12.00 RTA1-N 151193 240 1 CL00A310T-S 151147 8.00 12.00 RTA1-N 151193 208 3 CL00A310T-L 151150 4.00 6.30 RTA1-L 151191 240 3 CL00A310T-S 151147 4.00 6.30 RTA1-L 151191 480 3 CL00A310T-U 151148 1.90 2.70 RTA1-J 151189 575 3 CL00A310T-Y 151149 1.30 1.90 RTA1-H 151188 120 1 CL04A310M-J 151165 21.00 26.00 RTA1-U 151198 240 1 CL01A310T-S 151152 10.00 16.00 RTA1-P 151194 208 3 CL00A310T-L 151150 5.50 8.50 RTA1-M 151192 240 3 CL00A310T-S 151147 4.00 6.30 RTA1-L 151191 480 3 CL00A310T-U 151148 2.50 4.10 RTA1-K 151190 575 3 CL00A310T-Y 151149 1.90 2.70 RTA1-J 151189 120 1 CL04A310M-J 151165 25.00 32.00 RTA1-V 151199 240 1 CL02A310T-S 151157 10.00 16.00 RTA1-P 151194 208 3 CL00A310T-L 151150 5.50 8.50 RTA1-N 151192 240 3 CL00A310T-S 151147 5.50 8.50 RTA1-N 151192 480 3 CL00A310T-U 151148 2.50 4.10 RTA1-K 151190 575 3 CL00A310T-Y 151149 2.50 4.10 RTA1-K 151190 240 1 CL04A310M-S 151166 17.50 22.00 RTA1-T 151197 208 3 CL01A310T-L 151155 14.50 18.00 RTA1-S 151196 240 3 CL01A310T-S 151152 10.00 16.00 RTA1-P 151194 480 3 CL00A310T-U 151148 4.00 6.30 RTA1-L 151191 575 3 CL00A310T-Y 151149 4.00 6.30 RTA1-L 151191 240 1 CL45A310M-S 151170 30.00 40.00 RTA1-W 151200 208 3 CL04A310M-L 151169 21.00 26.00 RTA1-U 151198 240 3 CL25A310T-S 151161 17.50 22.00 RTA1-T 151197 480 3 CL01A310T-U 151153 8.00 12.00 RTA1-N 151193 575 3 CL00A310T-Y 151149 5.50 8.50 RTA1-N 151192 240 1 CL06A311M-S 151172 30.00 43.00 RTA2-E 151206 208 3 CL04A310M-L 151169 25.00 32.00 RTA1-V 151199 240 3 CL04A310M-S 151166 21.00 26.00 RTA1-U 151198 480 3 CL01A310T-U 151153 10.00 16.00 RTA1-P 151194 575 3 CL01A310T-Y 151154 8.00 12.00 RTA1-N 151193 240 3 CL06A311M-S 151172 30.00 43.00 RTA2-E 151206 480 3 CL25A310T-U 151162 17.50 22.00 RTA1-T 151197 575 3 CL02A310T-Y 151158 10.00 16.00 RTA1-P 151194 240 3 CL07A311M-S 151175 42.00 55.00 RTA2-G 151202 480 3 CL04A310M-U 151167 25.00 32.00 RTA1-V 151199 575 3 CL25A310T-Y 151163 17.50 22.00 RTA1-T 151197 208 3 CL09A311M-L 151179 64.00 82.00 RT2-J 151204 240 3 CL07A311M-S 151175 54.00 65.00 RT2-H 151203 480 3 CL04A310M-U 151167 25.00 32.00 RT1-V 151199 575 3 CL04A310M-Y 151168 21.00 26.00 RT1-U 151198 208 3 CL10A311M-L 166756 78.00 97.00 RT2-L 151205 240 3 CL09A311M-S 151178 64.00 82.00 RT2-J 151204 480 3 CL06A311M-U 151174 30.00 43.00 RT2-E 151206 575 3 CL04A310M-Y 151168 25.00 32.00 RT1-V 151199 (continued) Form P-RDF, Page 9 Blower Motors, Contactor, and Starters (cont'd) Replacement Line Voltage Starters for RDF units manfuactured before 1996 (cont'd) Type EE EE EE EE EE EE EE EE EE EE EE EE EE EE EE EE EE EE EE EE EE HP 1 1 1 1 1 1/2 1 1/2 1 1/2 1 1/2 2 2 2 2 3 3 3 3 5 5 5 5 7 1/2 Motor P/N 105659 159328 159328 158175 105662 159329 159329 158162 105664 159027 159027 158176 159186 159028 159028 159030 159029 159029 159029 111602 159331 CODE 39 - Starter (line voltage) and Overloads volt ph Mfg No. P/N min max GE # P/N 208 3 CL00A310T-L 151150 2.50 4.10 RTA1-K 151190 240 3 CL00A310T-S 151147 2.50 4.10 RTA1-K 151190 480 3 CL00A310T-U 151148 1.00 1.50 RTA1-G 151187 575 3 CL00A310T-Y 151149 1.00 1.50 RTA1-G 151187 208 3 CL00A310T-L 151150 4.00 6.30 RTA1-L 151191 240 3 CL00A310T-S 151147 2.50 4.10 RTA1-K 151190 480 3 CL00A310T-U 151148 1.90 2.70 RTA1-J 151189 575 3 CL00A310T-Y 151149 1.30 1.90 RTA1-H 151188 208 3 CL00A310T-L 151150 4.00 6.30 RTA1-L 151191 240 3 CL00A310T-S 151147 4.00 6.30 RTA1-L 151191 480 3 CL00A310T-U 151148 2.50 4.10 RTA1-K 151190 575 3 CL00A310T-Y 151149 1.90 2.70 RTA1-J 151189 208 3 CL00A310T-L 151150 8.00 12.00 RTA1-N 151193 240 3 CL00A310T-S 151147 5.50 8.50 RTA1-N 151192 480 3 CL00A310T-U 151148 2.50 4.10 RTA1-K 151190 575 3 CL00A310T-Y 151149 2.50 4.10 RTA1-K 151190 208 3 CL02A310T-L 151159 10.00 16.00 RTA1-P 151194 240 3 CL02A310T-S 151157 10.00 16.00 RTA1-P 151194 480 3 CL00A310T-U 151148 5.50 8.50 RTA1-M 151192 575 3 CL00A310T-Y 151149 4.00 6.30 RTA1-L 151191 208 3 CL04A310M-L 151169 21.00 26.00 RTA1-U 151198 Motor CODE 39 - Starter (line voltage) and Overloads Type HP P/N volt ph Mfg No. P/N min max GE # P/N EE 7 1/2 159332 240 3 CL25A310T-S 151161 17.50 22.00 RTA1-T 151197 EE 7 1/2 159332 480 3 CL00A310T-U 151148 8.00 12.00 RTA1-N 151193 EE 7 1/2 158164 575 3 CL00A310T-Y 151149 5.50 8.50 RTA1-N 151192 EE 10 159333 208 3 CL04A310M-L 151169 25.00 32.00 RTA1-V 151199 EE 10 159334 240 3 CL04A310M-S 151166 21.00 26.00 RTA1-U 151198 EE 10 159334 480 3 CL01A310T-U 151153 10.00 16.00 RTA1-P 151194 EE 10 158163 575 3 CL00A310T-Y 151149 10.00 16.00 RTA1-P 151194 EE 15 142440 208 3 CL06A311M-L 151173 30.00 43.00 RTA2-E 151206 EE 15 142441 240 1 CL06A311M-S 151172 30.00 43.00 RTA2-E 151206 EE 15 142441 480 3 CL25A310T-U 151162 17.50 22.00 RTA1-T 151197 EE 15 142289 575 3 CL02A310T-Y 151158 10.00 16.00 RTA1-P 151194 EE 20 159187 208 3 CL07A311M-L 151176 54.00 65.00 RTA2-H 151203 EE 20 142299 240 3 CL06A311M-S 151172 42.00 55.00 RTA2-G 151202 EE 20 142299 480 3 CL04A310M-U 151167 21.00 26.00 RTA1-U 151198 EE 20 142300 575 3 CL25A310T-Y 151163 17.50 22.00 RTA1-T 151197 EE 25 159031 208 3 CL09A311M-L 151179 64.00 82.00 RT2-J 151204 EE 25 159033 240 3 CL08A311M-S 151177 54.00 65.00 RT2-H 151203 EE 25 159033 480 3 CL04A310M-U 151167 25.00 32.00 RT1-V 151199 EE 30 159032 208 3 CL10A311M-L 166756 78.00 97.00 RT2-L 151205 EE 30 159034 240 3 CL09A311M-S 151178 64.00 82.00 RT2-J 151204 EE 30 159034 480 3 CL06A311M-U 151174 30.00 43.00 RT2-E 151206 CODE 40 - Replacement Parts for NEMA Starters - Apply to RDF Models MAnufactured prior to 10/92 NEMA Motor S tarters Size Coil Voltage 0 24 Volt 1 24 Volt 2 24 Volt 3 24 Volt 4 24 Volt 0 115 Volt 0 208 Volt 0 230 Volt 0 460 Volt 1 115 Volt 1 208 Volt 1 230 Volt 1 460 Volt 2 208 Volt 2 230 Volt 2 460 Volt 3 208 Volt 3 230 Volt 3 460 Volt 3 575 Volt 4 208 Volt GE# CR306B024 CR306C024 CR306D024 CR306E024 CR306F024 CR306B002 CR306B023 CR306B003 CR306B004 CR306C002 CR306C023 CR306C003 CR306C004 CR306D023 CR306D003 CR306D004 CR306E023 CR306E003 CR306E004 CR306E004 CR306F023 Reznor P/N for RDF-1 RDF-2 RDF-3 39919 39919 39919 39920 39920 39920 — 39921 39921 — 39922 39922 — — 91519 111523 — — 111524 111524 — 111525 111525 — 111522 111522 111522 111526 — — 111499 111499 — 111521 111521 — 111527 111527 — — 111528 111528 — 111529 111529 — 111530 111530 — 111531 111531 — — 111533 — — 111532 — — 119852 — — 111534 Holding Coils for NEMA S tarters Size Coil Voltage GE# 0/1 24 15D21G024 0/1 115 15D21G002 0/1 208 15D21G023 0/1 230 15D21G003 0/1 460 15D21G004 0/1 575 15D21G005 2 24 15D22G024 2 208 15D22G023 2 230 15D22G003 2 460 15D22G004 3 24 55-501336G024 3 208 55-501336G023 3 230 55-501336G003 3 460 55-501336G004 4 24 55-501463G024 4 208 55-501463G023 Form P-RDF, Page 10 Reznor P/N 48531 48507 48509 73795 48512 73601 93957 111927 111928 111929 95093 111931 111933 111932 102816 111935 NEMA Open Motor Starters Starter Heater Holding Coil NOTE: Effective 10/90, motor starter coils were changed to line voltage (For relay, see CODE 8, page 4) Heaters for NEMA Starters HP/Voltage/Phase GE# 5/208/3 CR123C18.0B 5/230/3 and 10/460/3 CR123C16.3B 5/460/3 CR123C8.67A 5/208/3 CR123C19.8B 7.5/208/3 CR123C25.0B 7.5/230/3 CR123C22.8B 7.5/460/3 CR123C12.5B 10/208/3 CR123C33.0B 10/230/3 CR123C30.3B 10/460/3 CR123C137B 15/208/3 CR123F56.7B 15/230/3 CR123FC40.0B 15/460/3 CR123C21.4B 20/208/3 and 25/230/3 CR123F77.28B 20/230/3 CR123F65.8B 25/208/3 and 30/230/3 CR123F91.4B 25/460/3 CR123C36.6B 30/208/3 CR123F10.4C 30/460/3 FA30B 30/575/3 F327B Reznor P/N 89941 or 110617 16193 or 110626 16192 or 110619 91542 16196 89924 or 110622 17257 or 110624 89947 or 110625 89949 or 110627 110623 91543 89933 19556 91544 91545 91546 16195 91547 119851 121175 Gas Regulators, Valves, and Pressure Switches CODE Description 41 1" Pressure Regulator, RV53-88 42 Regulator, 1" manifold, 5 PSI to 6" w.c., Maxitrol R600S 42A Standard brown spring for propane gas (in CODE 42) for lower pressure range 1 - 3.5" w.c. Std cadmium spring for natural gas (in CODE 42) for pressure range from 3.0 - 6.0" w.c., Maxitrol #R5310-36 Optional orange spring in CODE 42, for pressure range from 4.0 - 8.0" w.c., Maxitrol #R5310-48 43A Pilot Regulator, 3/8", Maxitrol #R400-S (replaced by CODE 43B) 43B Pilot Regulator, 3/8", Maxitrol 325-3 (functional replacement for 43A) 44A Pilot Valve, 110V, 3/8", G/C #S311AF02N6-CF5 (changed to 24V, CODE 44B, with units mfgd beginning 3/96) 44B Pilot Valve, 24V, 3/8", G/C #S3111AF02N6-CF5 (used from 3/96 to 9/03) 44C Pilot Valve, 24V, 3/8", M/H V8046C1030 (on units manufactured beginning 9/03) 45A Pilot Needle Valve, Nupro B-4JNR (on units mfgd from 1/91 through 1/96) 45B Pilot Needle Valve Conversion Kit (includes all parts needed to add pilot needle valve and change regulator on RDF Models manufactured prior to 1/91) 46A Solenoid Valve, 1", 120V, G/C #K3A562T (changed to 24V, CODE 46B, with units mfgd beginning 3/96) 46B Solenoid Valve, 1", 24V, G/C #K3A661T (on units mfgd prior to Series 3, 9/03) 47 1-stage Gas Valve, M/H VR8404M5569, Natural or Propane, 1" Used in Gas Control Option AG1 available on 48 Air Controller, 40-100°F (used as a ductstat) RDF Series 3 (manufactured beginning 9/03) Used in Gas Control Option AG3 available on 49 2-stage Gas Valve, M/H V8944B-1126, Natural, 1" 50 2-stage Ductstat, T678A1015, 60-110°F RDF Series 3 (manufactured beginning 9/03) 51 Mechanical Modulation Gas Valve, V5155-2548, 1", 40-120°F Used in Gas Control Option AG50 CODE 41 -Regulator, P/N 123950, Maxitrol RV53-88 CODE 44A - Pilot Valve, P/N 86967, 110V, G/C #S311AF02N6-CP5 CODE 46A Solenoid Valve, P/N 86966, G/C #K3A562, 120V CODE 46B Solenoid Valve, P/N 146472, G/C #K3A661T, 24V CODE 42 Regulator, P/N 86964, Maxitrol R600S CODE 42A Regulator Spring for CODE 42 CODE 44B Pilot Valve, P/N 145733, 24V, G/C #S311AF02N6CF5 CODE 44C - Pilot Valve, P/N 204769, M/H V8046C1030, 24V Components in Gas Control Option AG1 CODE 47 - P/N 159743, 1-Stage Gas Valve CODE 48 P/N 126170, Conroller CODE 43A - Pilot Regulator, P/N 86965, Maxitrol R400S (on units manufactured prior to 1/91; replaced by CODE 43B) CODE45A - Pilot Needle Valve, P/N 112462, Nupro #B-4JNR (on units manufactured between 1/91 and 3/96) Components in Gas Control Option AG3 CODE 49 P/N 203866, 2-Stage Gas Valve P/N 123950 86964 91787 97196 97351 86965 112644 86967 145733 204769 112462 112645 86966 146472 159743 126170 203866 41700 203868 CODE 43B - Pilot Regulator, P/N 112644, Maxitrol 325-03 (on units manufactured beginning 1/91) a functional replacement for CODE 42A CODE 45B - Pilot Needle Valve Conversion Kit, P/N 112645, for units manufactured before 1/91 Regulator, P/N 112644 Brass Elbow, P/N 93388 Needle Valve and Tubing, P/N 112710 CODE 51 - P/N 203868, Mechanical Modulation Valve, M/H V5115B-2548, in Gas Control Option AG50 CODE 50 P/N 41700, 2-Stage Ductstat Form P-RDF, Page 11 Gas Regulators, Valves, and Pressure Switches (cont'd) CODE 52A 52B 53 54 55 56 57 58 59A 59B 60 61 62 RDF Model 1-65 2-80 2-120 3-180 3-260 Valve only, 1" fluid power, Honeywell #V5055A1004 86992 Valve only, 1-1/4" fluid power, Honeywell #V5055A1012 N/A N/A N/A N/A 89356 Valve only, 2" fluid power, Honeywell #V5055A1038 N/A N/A N/A N/A N/A N/A 91079 Actuator only, 120V, fluid operated, Honeywell #V4055A1007 86993 Vent Valve, 3/4" G/C #S262 86996 Vent Valve, 1" G/C #S262A02N3FJ5 N/A N/A N/A N/A N/A N/A 91084 Used on RDF Series 3 (both Low Gas Pressure Switch, automatic 204375 High Gas Pressure Switch, manual reset 204297 include built-in vent limiter ) Low Gas Pressure Switch, Antunes #RLGP-A Used on RDF prior to Series 3 93849 High Gas Pressure Switch, Antunes #HGP-AMI 93850 (9/03) Vent Limiter, Maxitrol #12A09 123481 Manual Gas Valve, 1", Conbraco #50-4031 30257 Manual Gas Valve, 1-1/4", Conbraco #50-503-02 N/A N/A N/A N/A 89350 Manual Gas Valve, 2", Conbraco #50-703-02 N/A N/A N/A N/A N/A N/A 91072 159725, 1" Valve & 110758, 1" Ball Valve Adapter Gas Valve, Watts B-6000-UL-TH, with ball valve adapter, used on units mfgd 159729, 1-1/4" Valve & 110759, 1-1/4" Ball Valve Adapter beginning 7/90 replacing CODE 59A valves 159735, 2" Valve & 110760, 2" Ball Valve Adapter Manual Pilot Gas Valve, 3/8" 159720 Gas Control Regulator, 1", Maxitrol M611 R-88 87001 Gas Control Regulator, 1-1/4", Maxitrol MR212D N/A N/A N/A N/A 89351 Gas Control Regulator, 2", Maxitrol MR212E N/A N/A N/A N/A N/A N/A 91071 x 1" NPT (Same as Option CZ1) 124258 Gas Supply Regulator Kit, 5 psi 1-1/2" x 1-1/2" NPT (Same as Option CZ2) 124259 Description 1-20 CODE 53 - Vent Valve 3/4", P/N 86996, G/C #S262; 1", P/N 91084, G/C S262A0N3FJ5 CODE 52B CODE 52A (used with CODE 52B) Serial No. Size Gas P/N Code J2, J3, J4 1" N or P 86992 K2 1-1/4" N or P 89356 Part of Serial No. K4 2" N or P 91079 1-40 1-50 Gas Pressure Switehes - on RDF Series 3 (manufactured beginning 9/03) CODE 54 - Low Gas CODE 55 - High Gas Pressure Switch Pressure Switch (manual reset), (automatic), #C6097B1028, #C6097A1053, P/N 204297 P/N 204375 Valve codes J2, J3, J4, K2 and K4 Gas Pressure Switehes - prior to Series 3 (9/03) CODE 56 - Low Gas Pressure Switch, P/N 93849, Automatic Reset, Settings - 50% of minimum inlet gas pressure as stated on the unit rating plate CODE 57 - High Gas Pressure Switch, P/N 93850, Manual Reset, Settings - 125% of normal manifold gas pressure as stated on the unit rating plate P/N 87001, 1", Maxitrol M611 R-88 CODE 58 - Vent Limiter used with Pressure Switches, P/N 123481 CODE 59B - Valve and Adapter with Test Port Valve Adapter Form P-RDF, Page 12 CODE 61 Gas Control Regulators CODE 60 Pilot Gas Valve, P/N 159720 CODE 62 - Gas Regulator Kit, outlet pressure range 1-12" (maximum 5 psi) P/N 89351, 1-1/4", Maxitrol MR212D P/N 91071, 2", Maxitrol MR212E P/N 124258 (Same as Option CZ1), Kit includes Maxitrol 1"x1" NPT regulator P/N 124259 (Same as Option CZ2), Kit includes Maxitrol 1-1/2"x1-1/2" NPT regulator Modulating Gas Controls CODE 70 71 72 73 74 75 Description In Gas Control Option AG30, AG31 AG32 Serial No. Suffix MV-7 MV-8 AG33 MV-9 Temperature Sensor, Maxitrol Series 14, #TS114 Temperature Sensor, Maxitrol Series 14A, #TS114A Temperature Sensor, Maxitrol Series 44, #TS44E, 120°F max Temperature Sensor, Maxitrol Series 44, #TS44C, 140°F max Temperature Sensor, Maxitrol Series 94, #TS194A Temperature Sensor, Maxitrol Series 14E, #TS394-2B-4 Temperature Sensor, Maxitrol Series 14E, #TS194Q Mixing Tube, Maxitrol MTI-12 Amplifier, Maxitrol Series 14 & 14A, #A1014L Amplifier, Maxitrol Series 44, #A1044EL, 120°F maximum Amplifier, Maxitrol Series 44, #A1044CL, 140°F maximum Amplifier, Maxitrol Series 94, A1494 Amplifier, Maxitrol Series 14E, ADFM14 Amplifier, Maxitrol Series 44E-21 & 44ER-21, ADFM44 Signal Conditioner, Maxitrol Temperature Selector, Maxitrol Series 14, #TD114 AG33 MV-9 AG36 AG47 AG48, AG51 AG37 AG30, AG31 MV-B MV-D MV-E, MV-F MV-C MV-7 Temperature Selector, Maxitrol Series 14A, #TD114A Temperature Selector, Maxitrol Series 14E, #TDDFM14 Selectrastat (temperature selector), Maxitrol Series 44, #T-244 Temperature Selector, Maxitrol Series 44E, #TDDFM44 Temperature Selector, Maxitrol Series 94, #TD294E-609-0818 AG32 AG47 AG33 AG48, AG51 AG36 MV-8 MV-D MV-9 MV-E, MV-F MV-B Overriding Thermostat, Series 14, #T115 AG 30, 31, 32 MV-7, MV-8 CODE 70 Temperature Sensor AG36 MV-B MV-D, MV-E, AG47, AG48, MV-F AG51 All above AG 30, 31, 32 MV-7, MV-8 P/N 90324, Maxitrol #TS114; P/N 87106, Maxitrol #TS114A (illustrated); P/N 119617, Maxitrol #TS44E; P/N 194160, Maxitrol #TS44C; P/N 133228, Maxirol TS194A; Location P/N Discharge Discharge 90324 87106 119617 Discharge 194160 Discharge 133228 204452 Outside & Return Air Discharge 204453 Same as above 90323 148590 157915 Electrical Control 194159 Compartment (See 133229 204454 page 3.) 204450 134170 86988 (U.S.A.) Remote 101165 (Canada) Remote 87107 Remote 204455 Space 86990 Remote 204451 133230, 120°F Remote 159287, 160°F Space 24857 P/N 204452, Maxitrol #TS394-2B-4; P/N 204453, Maxitrol #TS194Q (illustrated) IMPORTANT NOTE: When replacing a temperature sensor on a Maxitrol MV-9 system (Option AG33), check the Model No. on the sensor.. P/N 119617 or 194160 is used on units manufactured beginning 2/92; P/N 87041 is used on units manufactured prior to 2/92. Sensors are not interchangeable; the sensor MUST match the amplifier. CODE 72 - Amplifier (Amplifiers are not interchangeable and must match the temperature sensor.) P/N 148590, P/N Maxitrol 204454, #A1014L Maxitrol (replaces #ADFM14 P/N 86976) P/N 194159, Maxitrol #A1044CL; P/N 157915, Maxitrol #A1044EL (replaces P/N 119616); P/N 86989, Maxitrol #A1044 (on systems mfgd prior to 2/91) P/N 133229, Maxitrol A1494 CODE 74 - Temperature Selectors (see chart for option application) P/N 86988, TD114 U.S. Models, Range 55-90°F P/N 101165, TD114, Canadian Models, Range 50-75°F; P/N 87107, TD114A, Range 80-130°F; P/N 123943, TD114B, Range 120-170°F P/N 204455, TD DFM14; P/N 204451, TD DFM44 P/N 86990, Selectrastat Maxitrol T-244 P/N 204450, Maxitrol #ADFM44 CODE 71 - Mixing Tube, P/N 90323 CODE 73 - Maxitrol Signal Conditioner, P/N 134170 (for computer control) P/N 133230, Maxitrol #TD294E- CODE 75 - P/N 24857, Maxitrol 609-0818, Dual Temperature #T115 Selector for Paint Booth Application, Option AG36 Overriding Thermostat, Option AG33 Form P-RDF, Page 13 Ignition System - Hot Surface Ignition Ignition system changed from spark to hot surface beginning 3/96. Description of Parts of Hot Surface Ignition System and Conversion Kits CODE Located in 80A Hot Surface Ignition Module, RAM #H4MC24-01- applies to RDF systems manufactured from the 3/96 to 9/03 (prior to RDF Series 3) - Serial No. Ignition System Code 72 electrical 80B Hot Surface Ignition Module, Synetek FC-IH1040B, single flame rod (Used on RDF Series 3 with control burner sizes from 250-1500 MBH, Options BL1-BL6) - Serial No. Ignition System Code 82 compart80C Hot Surface Ignition Module, Synetek FC-IH1040C, dual flame rod (Used on RDF Series 3 with ment. burner sizes from 1750-3000 MBH, Options BL7-BL13) - Serial No. Ignition System Code 81 81 Pilot Assembly for Hot Surface Ignition prior to RDF Series 3 (9/03) including: Pilot Pilot and Flame Flame Sensor, J/C #Y75MK-1D Ignitor Sensor Screw, #8-1/2" long Pilot bushing Hex head cap screw, #10-32x3/8" lg Hot Surface Ignitor, Norton #401E Pilot, Sensor, and Ignitor for Model RDF Series 3 82A Pilot for RDF Series 3, 250-1500 MBH 82B Pilot for RDF Series 3, 1750-3000 MBH 83 Hot Surface Ignitor, Norton #401E 84 Flame Sensor, J/C #Y75MK-1D (Note: CODE 84 is for replacement of the flame sensor at the ignitor end of the burner only. 1750-3000 MBH burners have a second flame sensor. For replacement, see CODE 99.) 85 Ignition Conversion Kit from Spark Pilot with for unit with a 200VA transformer either a rectification type (CODE 94) or for 115V unit with an 80VA transformer ultraviolet flame (CODE 95) sensor to hot for 208V unit with an 80VA transformer surface ignition. for 240V, 480V, or 575V unit with an 80VA transformer CODE 80A, P/N 157953, Hot Surface Ignition Module, RAM H4MC24-01 CODE 80B, P/N 204376, Hot Surface Ignition Module, Synetek FC-IH1040B, for burner with a single flame rod 204376 204166 120048 122840 134706 38529 121730 90167 121865 127910 122840 121865 134706 146268 146318 146319 146320 CODE 80C, P/N 204166, Hot Surface Ignition Module, synetek FC IH1040C, for burner with a double flame rod Pilot, Hot Surface Ignitor, and Flame Sensor on RDF Series 3 Burner Loc ati ( n o on sho t wn) CODE 82 CODE 84 CODE 83 Form P-RDF, Page 14 P/N 157953 Ignition System - Spark Ignition System (discontinued 3/96) Description of Components of Spark Ignition System (Discontinued on units beginning 3/96. See conversion kits in CODE 85, page 13.) 86 Flame Sensor Safety Relay, Rectification, Honeywell With #RA890F1270 Code 87 Flame Sensor Safety Relay, Rectification, Honeywell #R7795B93 1009 (less CODE 80) With 88 Flame Sensor Safety Relay, Ultraviolet, Honeywell Code 89 Flame Sensor Safety Relay, Ultraviolet, Honeywell #R7795A94 1009 (less CODE 90) 90 Prepurge Timer Board (prepurge relay), M/H ST795A-1031 (used in CODES 87 and 89) 91 Subbase only used with CODES 87 (P/N 89407) & 89 (P/N 89436) , Honeywell #Q795A-1004 92 Subbase only used with CODES 86 (P/N 86972) & 88 (P/N 89409), Honeywell #Q270A-1024 93 Flame Probe, Auburn #AA67-7892-1 (std on units mfgd before 9/88; used w/CODE 84 or 85) 94 Ultraviolet Minipeeper Detector, Honeywell #C7027A (std on units from 9/88 -2/96; optional on prior units; used with CODE 88 or 89) RDF 1-20, 40, 50, 65 95 Flame Rod RDF 2-80, 120 Wire RDF 3-180, 260 Assembly 95A Housing only for Flame Rod Wire Assy, AMP #1-48016-0 RDF 1-20, 40, 50, 65 96 Ignitor RDF 2-80, 120 Wire RDF 3-180, 260 Assembly 97A Spark Plug, Auburn #27750 I-31, Maxon #18075 97B Spark Plug, #23539 Sapco 14mm (used prior to CODE 97A) CODE CODE 95, Flame Rod Wire Assy for Spark Ignition System Housing only, P/N 19127 CODE 96, Ignitor Wire Assy for Spark Ignition System P/N Flame Sensor Safety Relays and Subbases for Spark Ignition System 86972 89407 89409 89436 Codes 87 and 89 Codes 86 and 88 89408 89410 86973 87937 89411 87904 89614 113952 19127 87906 89627 91362 87936 179342 CODE 90, P/N 89408 CODE 91, P/N 89410 CODE 92, P/N 86973 CODE 93, P/N 87937, Flame Probe (std on units with date codes from AJH to ANH) CODE 94, P/N 89411, Ultraviolet Detector (std on units with date codes from ANI to AVB; optional on prior units) Spark Plug for Spark Ignition System CODE 97A, P/N 87936 (illusrated) CODE 97B, P/N 179342, #23539 Sapco 14mm (used prior to CODE 97A) Burners for RDF Series 3 (manufactured beginning 9/03) RDF Series 3 systems use Midco HMA-700 Series Burners. The Burner P/N listed below includes the burner, the mixing plates, and the end plate. 1750-3000 MBH (4260") burners also include CODES 99 & 100. Burner CODE 98 - Model RDF Series 3 BURNER Length MBH P/N 6" Burner 250 203312 12" Burner 500 203313 18" Burner 750 203314 24" Burner 1,000 203315 30" Burner 1,250 203316 36" Burner 1,500 203317 42" Burner 1,750 or 2,000 203318 48" Burner 2,250 203319 54" Burner 2,500 203320 60" Burner 2,750 or 3,000 203321 CODE 99 - Second Sensor (at the end of the burner opposite the ignitor) 100 on 42-60" Burners, P/N 210766 CODE 100 - Holder for CODE 99, 99 P/N 210767 Mixing Plates Burner End Plate CODE 83 Ignitor CODE 82 - Pilot Gas Supply Assembly Form P-RDF, Page 15 Burners for RDF Systems manufactured prior to Series 3 (9/03) CODE Replacement Burners (burners include cast iron burner and stainless steel mixing plates) Size BTU Burner only by size Replacement burner assembly only for all burner assemblies with inlet end for units with a spark ignition system (does not include end plates, order CODE 102B) 101 6" Burner 250,000 123405 145757 Mixing Plates 12" Burner 500,000 123665 145758 18" Burner 750,000 123684 145759 24" Burner 1,000,000 123696 145760 30" Burner 1,250,000 123700 145761 36" Burner 1,500,000 145140 145762 42" Burner 1,750,000 145159 145763 48" Burner 2,000,000 145162 145764 54" Burner 2,250,000 145169 145765 60" Burner 2,500,000 145172 145766 Inlet end enclosure for spark ignition is 66" Burner 2,750,000 145175 145767 different from currently manufactured Cast Iron 72" Burner 3,000,000 145178 145768 burner assemblies. Burner 101A Replacement burner mixing plate only, 6" section, for all of the burners listed above. Refer to Operation/ Maintenance/Service, Form O-ADF/DV/RDF, Burner Cleaning, for instructions on burner service. 102A Burner End Plate only for HOT Surface Ignition 102B Burner End Plate only for Spark Ignition 103 Adjustable "mirror" to view burner and pilot flame through viewport on control side of cabinet (on units manufactured beginning 3/92) - complete assembly Components: Reflecting mirror only Bracket assy including swivel ball joint Swivel ball joint only Mirror support only (attaches to cabinet) Installed Burner Assembly 101A P/N 116104, Maxon P/N 20580 Total quantity of plates per burner size, 6"-2; 12"-4"; 18"-6; 24"-8; 30"-10; 36"-12; 42"-14; 48"-16; 54"-18; 60"-20; 66"-22; 72"-24 (2) P/N 95473 - For all sizes of heaters and burners (2) P/N 102957 - For all sizes of heaters and burners P/N 119480 - Sizes 1-20 - 1-65; P/N 119481 - Sizes 2-80 - 3-260 P/N 116212 - All Sizes P/N 119483 - All Sizes P/N 119115 - All Sizes P/N 119360 - Sizes 1-20-1-65; P/N 116210 - Sizes 2-80 - 3-260 CODE 103 - Pilot/Burner Mirror Assembly 12" Burner CODE 102A - Burner End Plate showing the hot surface ignition system Hot surface ignition is standard with units manufactured beginning 3/96; for ignition conversion kit see CODE 85, page 13. Pilot and Ignitor Assembly, See CODE 81, page 13 Burner Inlet Flange, P/N 123449, (must be sealed with key graphite paste, P/N 146269) CODE 102B Burner End Plate for burner with spark ignition, P/N 102957 Form P-RDF, Page 16 Instructions to install pilot/burner mirror assembly on RDF units manufactured prior to 3/92. All Sizes (requires two #10 x 1/2" sheet metal screws) - (1) Turn off gas and power. (2) Remove the burner door panel on the side of the unit opposite the controls. (3) Remove the burner control door panel. RDF 1 - (1) On the side of the unit opposite the controls, position the mirror on the center post inner liner (refer to drawing on page 5, inner liner of CODE 12) so that the bottom of the mirror is slightly higher than the top of the burner. (2) Mark and drill two 1/8" holes. RDF 2 and 3 - On the side of the unit opposite the controls, locate the two small holes on the horizontal surface of the air deflector (aka return air damper support). All Sizes - (1) Attach the mirror assembly with field-supplied sheet metal screws. (2) On the back of the mirror support bracket, tighten the ball joint (swivel) bolt head. (3) Adjust the mirror so that the burner and the pilot are visible when looking through the viewport in the burner control panel. (4) Close the door panels. Dampers and Controls RDF Series 3 (units Discharge Dampers manufactured Options AQ 3, 4; AR 19, 20, 33, 36 beginning 9/03) Bypass Dampers Options AR 19, 20, 22, 23, 33, 34, 35, 36, 37 Return Dampers Options AR 22, 23, 34, 37 AR 20 or 23 AR22 AR23 AR 19 Remote Pressure Null or 22 Switch, CODE 33, page 6. Remote Potentiometer, CODE 32, page 6. Options AR 36 and 37 have a Remote Photohelic Pressure Sensor, CODE 34, page 6. Dampers in RDF Series 3 (units manufacturered beginning 9/03) Code Description 110 Bypass Damper In Option RDF-1 AR 19, 20, 22, 23, 203602 - 26" x 12" 33, 34, 36, 37 111 Return Air Damper AR 22, 23, 34, 37 203602 - 26" x 12" 112 Discharge Damper AQ 3, 4; AR19, 20, 15869 - 21-1/8" x 18-1/2" 33, 36 RDF-2 RDF-3 203604 - 53-1/2" x 17-3/4" 203603 - 65-3/4" x 20" 203604 - 53-1/2" x 17-3/4" 203603 - 65-3/4" x 20" 89355 - 27-1/4" x 27-1/4" 91073 - 37" x 37" Damper Motors and Linkages in RDF Series 3 (units manufacturered beginning 9/03) CODE Description/Damper Arrangement 2-Position, 100% Makeup Air 115 Variable Air Volume with Manual Potentiometer (CODE 32, 116 page 6) 117 Discharge Variable Air Volume with Automatic Pressure Switch (CODE Damper 33, page 6) Variable Air Volume with Computer Control through Signal 118 Motor Conditioner (CODE 73, page 13) Variable Air Volume with Photohelic Pressure Sensor (CODE 119 34, page 6) Variable Air Volume 120 Bypass Damper Motor Return Air with Manual Potentiometer (CODE 32, page 6) 121 Return Air with Automatic Pressure Switch (CODE 33, page 6) 122 Return Air Variable Air Volume with Computer Control through Signal 123 Damper Conditioner (CODE 73, page 13) Motor Variable Air Volume with Photohelic Pressure Sensor (CODE 124 34, page 6) 125 Damper Crank Arm, M/H #26026K 126 Ball Joint, M/H 27518 127 Damper Crank Arm Kit, J/C #9000-153 128 129 Damper Crank Arm, W/R 135-0007 Damper Crank Arm, W/R 135-0002 In Option AQ3, AQ4 RDF-1 RDF-2 RDF-3 159892, J/C M9216-BGC-2 AR19 204269, J/C M9216-JGA-2 AR20 204270, J/C M9109-AGA-2 AR33 204271, J/C M9216-GGC-2 AR36 204270, J/C M9109-AGA-2 AR 19, 20, 22, 23, 33, 34, 36, 37 204268, J/C M9108-AGD-2 AR22 AR23 204269, J/C M9216-JGA-2 204270, J/C M9109-AGA-2 AR34 204271, J/C M9216-GGC-2 AR37 204270, J/C M9109-AGA-2 (1) AR 22, 23, 34 (1) AQ 3, 4 (2) AR19, 20, 22, 23, 34, 37 (2) AQ 3, 4 (1) AR 22, 23; (1) AQ 3 (1) AR 34, 37 (1) AQ 3, 4 (1) AQ 4 -- 12635 12635 -- 12636 12636 -- 194200 194200 -- 66278 --- 66278 66277 Form P-RDF, Page 17 Dampers and Controls (cont'd) RDF Series 3 (units manufactured beginning 9/03) (cont'd) CODE 115 2-Position Damper Motor, J/C M9216BGC-2, P/N 159892 Modulating Damper Motors (See Chart on page 16 for application.) CODES 116, 121 Discharge or Return Air Damper Motor, J/C M9216-JGA-2, P/N 204269 CODE 125, Damper Crank Arm, P/N 12635, M/H #26026K CODES 117, 119, 122, 144, Discharge or Return Air Damper Motor, J/C M9109AGA-2, P/N 204270 CODE 126, Ball Joint, P/N 12636, M/H #27518 CODE 120 - Bypass Damper Motor, J/C M9108-AGD-2, P/N 204268 CODE 127, Damper Crank Arm Kit, P/N 194200, J/C #9000-153 CODES 118, 123 Discharge or Return Air Damper Motor, J/C M9216-GGC-2, P/N 204271 CODE 128, Damper CODE 129, Damper Crank Arm Kit, P/N Crank Arm Kit, P/N 66278, W/R 135-0007 66277, W/R 135-0002 CODE 130 - Damper Rods in RDF Series 3 (units manufactured beginning 9/03) Damper Arrangement Discharge, 2-Position, 100% Makeup Air (Vertical) Discharge 2-Position, 100% Makeup Air (Horizontal) Return Air Damper Options AQ3 AQ4 AR34, 37 RDF-1 RDF-2 RDF-3 112555 - 1/4" x 16" 89640 - 1/4" x 7-1/2" 89640 - 1/4" x 7-1/2" 112555 - 1/4" x 16" 89970 - 1/4" x 38" 91428 - 1/4" x 24" --5120, 1/4" X 7-7/8" Dampers and Controls RDF Systems prior to Series 3 (manufactured before 9/03) Control and Damper Locations KEY: 1 - Burner 2 - Discharge Damper Motor (Options AR19 & 20) 3 - Discharge Damper (Options AR19 & 20) 4 - Manual Reset Limit 5 - Automatic Limit 6 - Discharge Air Sensor 7 - Blower Motor 8 - Damper Motor (Optional) 9 - Return Air Damper (Options AR22 & 23) 10 - Bypass Damper (Options AR19, 20, 22 & 23) Sizes 2-80, 2-120, 3-180, 3-260 Outside Air Hood Sizes 2-80, 2-120, 3-180, 3-260 Dampers in RDF Systems prior to Series 3 (9/03) Code Description In Option AR 19, 20, 140 Bypass 22, 23 Damper Return Air AR 22, 23 Damper 141 Discharge AQ 3, 4; Damper AR19, 20 142 Bypass Damper AR 22, 23 Adjustment Arm Form P-RDF, Page 18 RDF-1 87117 32"x10" 87117 32"x10" 86999 22"x18" RDF-2 89354 22"x54" 89354 22"x54" 89355 28"x28" In the Electrical Compartment -Sizes 1-20, 1-40, 1-50, 1-65 RDF-3 91074 30"x68" 91074 30"x68" 91073 37"x37" 111309 111309 111309 Dampers and Controls (cont'd) RDF Systems prior to Series 3 (manufactured before 9/03) (cont'd) Damper Motor and Accessories by Damper Arrangement and Option CODE Description/Damper Arrangement 143 Motor Discharge, 2-Position, 100% Makeup Air 144 Motor Discharge, Variable Air Volume with Manual Potentiometer (CODE 33, page 6) 145 Motor Discharge, Variable Air Volume with Automatic Pressure Switch (CODE 34, page 6) 146 Motor Bypass, Variable Air Volume In Option AQ3, AQ4 RDF-1 87000 M/H M8415A1004 RDF-2 RDF-3 97385 W/R 3402-9 115681* M/H M9175A1015 (replaces 53928) 115683* 87116 AR19 AR20 M/H M6414A1009 M/H M6194B1011 (replaces 87059) 115683* M/H M6194B1011 (replaces 87059) 115681* M/H M9175A1015 (replaces 53928) 115683* 87116 M/H M6414A1009 M/H M6194B1011 (replaces 87059) 113963 113963 AR19, AR20, AR22, 87116 AR23 M/H M6414A1009 147 Motor Return Air with Manual Potentiometer AR22 (CODE 33, page 6) 148 Motor Return Air with Automatic Pressure AR23 Switch (CODE 34, page 6) 149 Auxiliary End Switch only for M/H damper motors, M/H Q607B1067 150 Damper Crank Arm, M/H #26026K -used in all (2) AR19,20,22,23; 12635 12635 damper arrangements (1) AQ3,4 (4) AR19,20,22,23; 151 Ball Joint, M/H 27518 -used in all damper 12636 12636 (2) AQ3,4 arrangements 116209* (2) AR19,20,22,23 152 Damper Motor Crank Arm, M/H 221455A 116209* 20874 Damper Motor Crank Arm & Clip, M/H 7616BR(used w/obsolete mtrs) 20874 *When installing motors P/N 115681 or 115683 to replace P/N 53928 or 87059, it is necessary to change the motor crank arm. Order P/N 116209. CODE 143 - Damper Motor for 2-Position Discharge Damper, 100% Makeup Air (Options AQ3 and AQ4) P/N 87000, M/H #M8415A1004, used on RDF 1 P/N 97385, W/R #3402-9, used on RDF 2 & 3 Codes 144 and 147 Modulating Damper Motor, P/N 115681, M/H M9175A1015, used in Options AR19 and AR22 on RDF 1, 2 & 3 CODE 149 - Auxiliary End Switch, P/N 113963, M/H Q607B1067 Codes 145, 146 and 148 - Modulating Damper Motor used for the discharge damper in Option AR20; for the bypass damper in Options AR19, 20, 22, and 23; and for the return air damper in Option AR23 P/N 87116, M/H #M6414A1009, used on RDF 1 CODE 150 Damper Crank Arm, P/N 12635, M/H #26026K P/N 115683, M/H #M6194B1011 used on RDF 2 & 3 CODE 151 - Ball Joint, P/N 12636, M/H #27518 CODE 152 - Damper Motor Crank Arms P/N 116209, M/H 221455A, used in Options AR19, 20, 22, and 23 (required when replacing obsolete motors; see note on page 16.) P/N 20874, M/H 7616BR, motor crank arm used with obsolete motor P/N's 53928 and 87059 CODE 153 - Damper Rods (Damper rods may require being cut to desired length.) Damper Arrangement Discharge 2-Position, 100% Makeup Air (Horizontal) Discharge, 2-Position, 100% Makeup Air (Vertical) Discharge, Variable Air Volume with Potentiometer Discharge, Variable Air Volume with Pressure Sensor Bypass, Variable Air Volume and Return Air Return Air with Potentiometer Return Air with Pressure Sensor Options AQ4 AQ3 AR19 AR20 AR19,20,22,23 AR22 AR23 RDF-1 11560 - 1/4" x 16" 11560 - 1/4" x 16" 11560 - 1/4" x 16" 11560 - 1/4" x 16" 5120 - 1/4" x 7-7/8" 11560 - 1/4" x 16" 11560 - 1/4" x 16" RDF-2 89970 - 1/4" x 38" 89640 - 1/4" x 7-1/2" 14226 - 1/4" x 11" 14226 - 1/4" x 11" 90056 - 1/4" x 5" 14226 - 1/4" x 11 14226 - 1/4" x 11 RDF-3 91428 - 1/4" x 24" 89640 - 1/4" x 7-1/2" 91428 - 1/4" x 24" 91428 - 1/4" x 24" 89640 - 1/4" x 7-1/2" 91422 -1/4" x 18-1/2" 91422 -1/4" x 18-1/2" Form P-RDF, Page 19 Remote Console Note: Console height changed 10/01. Console parts listed are currently manufactured size. NOTE: A remote console was standard with RDF Models manufactured prior to 9/03. Beginning with RDF Series 3 (units manufactured beginning 9/03), the remote console is an option. 162 161 164 163 Replacement Components CODE 160 161 162 31, page 6 32, page 6 74, page 13 Description P/N Remote Console Box 10-9/16" x 7-1/4" x 2-5/8" 107010 Remote Console Box 15-9/16" x 7-1/4" x 2-5/8" 107011 Mounting Ring for 10-1/16" long box 107014 Mounting Ring for 15-1/16" long box 107015 Light with red lens, Solico #5TD1L-R-B5 101889 Bushing for installing light above on old-style console 106747 DPDT Switch, Cutler Hammer #7561K6 101900 Potentiometer, Honeywell 112894FA 16110 Temperature Selector, Option AG30, AG31 86988 or 101165 Temperature Selector, Option AG32 87101 Temperature Selector, Option AG33 86990 Temperature Selector, Option AG47 204455 Temperature Selector, Option AG48, AG51 204451 CODE 160 - Console Box Technical Data of the Remote Console (Variations depend on options selected; consult custom wiring diagram for controls and to determine wiring required.) Dimensions (inches) Temperature Control Qty of Potentiometer Selector or Switch Lights* *** L**** H**** D Sensor ** 1-5 Yes 3 Yes No 10-13/16 7-3/8 2-5/8 Yes 3 No No 10-13/16 7-3/8 2-5/8 Yes 3 Yes Yes 15-13/16 7-3/8 2-5/8 Yes 3 No Yes 10-13/16 7-3/8 2-5/8 Yes 4 Yes No 15-13/16 7-3/8 2-5/8 Yes 4 No Yes 15-13/16 7-3/8 2-5/8 Yes 4 Yes Yes 15-13/16 7-3/8 2-5/8 Yes 4 No No 15-13/16 7-3/8 2-5/8 * 3 - Blower On, Burner On, and Safety Lockout; 4th light is Dirty Filter Indicator ** On the console with Gas Control Options AG 30, 31, 32, 33, 47, 48, 51 *** On the console with Air Control Options AR19 or AR22 **** Subtract 7/8" when recessing Form P-RDF, Page 20 /16 (33 2-3/8 (60) ) 6( 5-1 152 5/3 ) 2( 139 ) 1-3 /32 (28 ) 4-7/16 (113) 1-3 /32 (28 ) Disconnect Switch CODE 170 - OUTDOOR Disconnect Switches 30 Amp, 240 Volt, Non-Fusible 30 Amp, 240 Volt, Fusible 30 Amp, 600 Volt, Non-Fusible 30 Amp, 600 Volt, Fusible 60 Amp, 240-Volt, Non-Fusible 60 Amp, 240-Volt, Fusible 60 Amp, 600 Volt, Non-Fusible 60 Amp, 600-Volt, Fusible 100 Amp, 240-Volt, Non-Fusible 100 Amp, 240-Volt, Fusible 100 Amp, 600 Volt, Non-Fusible 100 Amp, 600-Volt, Fusible 200 Amp, 240-Volt, Non-Fusible 200 Amp, 240-Volt, Fusible 200 Amp, 600 Volt, Non-Fusible 200 Amp, 600-Volt, Fusible USA Only Opt P/N CP5 40269 CP6 87147 CP7 20367 CP8 20368 CP30 161469 CP17 89932 CP38 90973 CP20 90974 CP31 162834 CP18 90973 CP39 155013 CP36 155010 CP32 155007 CP19 91076 CP40 155014 CP37 155011 Canada Only Opt P/N --CP59 208054 CP42 208046 --CP61 208056 CP44 208048 --CP63 208058 CP46 208050 --CP65 208060 CP48 208052 General Guide to Outdoor/Raintight Switches by Option Code (unit motor/voltage availability varies by model/size) USA Outdoor Voltage/ Motor Canada Outdoor Amps Phase HP Fusible Non-Fuse Fusible Non-Fuse 1/4 to 1-1/2 30 CP6 CP5 CP42 CP59 115/1 2 to 3 60 CP17 CP30 CP44 CP61 1/4 to 3 30 CP6 CP5 CP42 CP59 208/1 and 5 to 10 60 CP17 CP30 CP44 CP61 230/1 1/4 to 5 30 CP6 CP5 CP42 CP59 208/3 and 7-1/2 to 15 60 CP17 CP30 CP44 CP61 230/3 20 to 25 100 CP18 CP31 CP46 CP63 30 200 CP19 CP32 CP48 CP65 1/4 to 15 30 CP8 CP7 CP42 CP59 460/3 and 20 to 30 60 CP20 CP38 CP44 CP61 575/3 CODE 171 - INDOOR Disconnect Switches 30 Amp, 240 Volt, Non-Fusible 30 Amp, 240 Volt, Fusible 30 Amp, 600 Volt, Non-Fusible 30 Amp, 600 Volt, Fusible 60 Amp, 240-Volt, Non-Fusible 60 Amp, 240-Volt, Fusible 60 Amp, 600 Volt, Non-Fusible 60 Amp, 600-Volt, Fusible 100 Amp, 240-Volt, Non-Fusible 100 Amp, 240-Volt, Fusible 100 Amp, 600 Volt, Non-Fusible 100 Amp, 600-Volt, Fusible 200 Amp, 240-Volt, Non-Fusible 200 Amp, 240-Volt, Fusible 200 Amp, 600 Volt, Non-Fusible 200 Amp, 600-Volt, Fusible USA Only Opt P/N CP1 40267 CP2 40268 CP3 50365 CP4 50366 CP21 161462 CP17 89932* CP23 161464 CP20 90974* CP22 161463 CP18 90973* CP24 164330 CP36 155010* CP26 155005 CP19 91076* CP35 155009 CP37 155011* Canada Only Opt P/N --CP58 208053 CP41 208045 --CP60 208055 CP43 208047 --CP62 208057 CP45 208049 --CP64 208059 CP47 208051 General Guide to Indoor Disconnect Switches by Option Code (unit motor/voltage availability varies by model/size) USA Indoor Voltage/ Motor Canada Indoor Amps Phase HP Fusible Non-Fuse Fusible Non-Fuse 1/4 to 1-1/2 30 CP2 CP1 CP41 CP58 115/1 2 to 3 60 CP27 CP21 CP43 CP60 1/4 to 3 30 CP2 CP1 CP41 CP58 208/1 and 5 to 10 60 CP27 CP21 CP43 CP60 230/1 1/4 to 5 30 CP2 CP1 CP41 CP58 208/3 and 7-1/2 to 15 60 CP27 CP21 CP43 CP60 230/3 20 to 25 100 CP28 CP22 CP45 CP62 30 200 CP29 CP26 CP47 CP64 460/3 and 1/4 to 15 30 CP4 CP3 CP41 CP58 575/3 20 to 30 60 CP33 CP23 CP43 CP60 * Actually an outdoor switch. Form P-RDF, Page 21 Blowers Hardware for 3/8" Motor Mounting Bolts 180 183 Hardware for 5/16" Motor Mounting Bolts Blower Motor - RDF 2 and 3 183 184 185 Blower and Motor - RDF 1 CODE Description 180 Blower with shaft and bearings Size Mfg # 1-20 1357 1-40 1360 10" A10-10AC 12" A12-12AC 1-50 86983 1-65 86984 15" 18" A15-15A A18-18A Class Shaft Class 1 1" — — — — Size Mfg # 180A Blower Class Shaft Class 1 Blowers 11302 3/4x22 11303 1x22 100747 1x23 100748 1x28.8 Class 2 Blowers — — — — Class 1 Blowers 7310 10437 Class 2 Blowers — — Shaft 180B Blower Bearings 181 10437 10437 Ball Bearings (2) — — 2-80 92343* 2-120 89345 3-180 91067 3-260 91069 18" 20" 22" 30" 022920-03 027550-02 020350-01 029353-02 A20-20K A22-22K A30-22K Class 1 Class 1 Class 1 Class 1 1-7/16" 1-7/16" 1-7/16" 1-11/16" 89658 — 91068 91070 18" 0217142-15 A18-18A Class 2 1-7/16" 100748 100746 2x28.8 1.44x 37.25 100749 — 1.44x 38.5" 10437 106942 1.44" 106942 1.44" Pillowblock 111389 111389 22" 30" 029353-01 029353-03 A22-22K A30-22K Class 2 Class 2 2-3/16" 2-11/16" 100751 100754 1.44x 1.69x 45.73 46.25 100752 101705 2.19x 2.69x 45.75" 46.25' 106942 100755 1.44" 1.69" Pillowblock (2) — 100753 101710 2.19" 2.69" (2) Pillowblock (2) 111389 111389 111389 126588** 126588** 111390 111390 111390 External Shaft Support Bearing Plate 111389 111389 111389 - for units with dampers (Options AQ3, AQ4 and/or AR19, AR20, AR22, AR23) 182 Bearing BF-1127-502-A - for units 111390 111390 111390 111390 111390 with dampers, Options AQ3, AQ4, and/or AR19, AR20, AR22, AR23) 183 Blower Motor Mounting Plate 12578 12578 12578 12578 94371 94371 94371 94371 184 Mtr Mounting Plate Left Support 87015 87015 87015 87015 94369 94369 94369 94369 185 Mtr Mounting Plate Right Support 87016 87016 87016 87016 94369 94369 94369 94369 186 Blower Support (Horzntl Discharge) 207840 207840 207840 207840 (2)207461 (2)207461 (3)207462 (3)207462 *Effective 8/90, RDF 2-80 models are no longer manufactured with a Class 1 blower. P/N 92343 is no longer available. Replace with Class 2 blower, P/N 89658 and Q1-1-7/16" Bushing, P/N 16177. ** Order P/N 126588 when heater has Option AR23, outside and return dampers controlled by a remote pressure sensor. Form P-RDF, Page 22 Drives Replacement Drive Components are Listed in Tables on pages 2331. Tables are by RDF Size, Type of Motor, Motor HP, and RPM (Option AM, see chart top of page 23), CODE 200 - Motor Sheave CODE 201 - Blower Sheave CODE 202 - Belt CODE 203 - Bushing NOTE: Read each drive table carefully. They are not all in the same format. Belt Tension - Check belt tension. Proper belt tension is important to the long life of the belt and motor. A loose belt will cause wear and slippage. Too much tension will cause excessive motor and blower bearing wear. If adjustment is required, adjust belt tension by means of the adjusting screw on the motor base until the belt can be depressed 1/2" to 3/4". Tighten the lock nut on the adjusting screw. Be sure the belt is aligned in the pulleys. Blower Speed Adjustment - Units are set at the factory for the RPM required to meet the CFM and external static pressure specified on the order. If the estimated external static is incorrect, or changes are made to the duct system, the blower RPM may have to be changed. Motors are equipped with adjustable pitch pulleys which permit adjustment of blower speed. To make adjustments on all RDF-1 units and on RDF-2 and RDF-3 units with less than 7-1/ 2 HP motor (units with a Browning motor sheave Model VP), follow these instructions: 1) Loosen belt tension and remove belt. 2) Loosen the set screw on the side of the pulley away from the motor. 3) Turn adjustable half of the pulley inward to increase blower speed or outward to decrease speed. One turn of the pulley will change speed 8 to 10%. 4) After setting the pulley, tighten the set screw on the flat portion of the pulley shaft. 5) Replace belts and adjust belt tension. 6) Always check motor amps with an amp meter after RPM adjustment. The maximum motor amp rating on the nameplate must not be exceeded. In RDF-2 and RDF-3 models with 7-1/2 HP and larger motors (units with adjustable Browning motor sheave Model MV), follow these instructions for adjusting RPM: 1) Slack off all belt tension by moving the motor toward driven shaft until the belts are free of grooves. For easiest adjustment, remove the belts from the grooves. 2) On the outer locking ring, locate the two locking screws that are directly across from each other. Loosen, but do not remove, those two screws. Do not loosen any other screws. 3) Adjust sheave to desired pitch diameter by turning the outer locking ring. One complete turn of the outer locking ring will result in .233" change in pitch diameter. To increase blower speed, decrease diameter. CAUTION: Do not adjust sheaves in either direction to the point where moveable and stationary flanges are in contact. 4) After completing adjustment, tighten both locking screws in the outer locking ring. 5) Replace belts and move motor away from the drive shaft to apply sufficient belt tension to prevent slippage. Be sure that the belts are aligned in the pulley grooves properly and are not angled from pulley to pulley. 6) Always check motor amps with an amp meter after RPM adjustment. The maximum motor amp rating on the nameplate must not be exceeded. Blower Pulley - Size 2-80, 2-120, 119 and 120 systems equipped with 3 and 5 HP motors with a 15.4" diameter and larger blower pulley or a 7-1/2 HP and larger motor and all Size 3-180, 3260, 122, and 130 systems are equipped with a split taper bushing in the blower pulley. The split taper bushings must be loosened in order to remove the pulley. Follow these instructions to loosen the bushing. 1) Notice that there are three cap screws in the bushing and two holes without screws, called push-off holes (see illustration). 2) Remove the three cap screws. 3) Put two of the cap screws into the two push-off holes. Tighten these two screws evenly until the pulley is loosened. 4) Pulley may now be removed from the shaft. 2 Push-Off Holes Split Taper Bushing 3 Cap Screws Form P-RDF, Page 23 Drive Components (cont'd) Notes and Key to Option Codes on Drive Tables, pages 24 - 32 Option ............... RPM AMA3 ............... 301-350 AMA4 ............... 351-400 AM1 .................. 401-450 AM2 .................. 451-500 AM3 .................. 501-550 AM4 .................. 551-600 AM5 .................. 601-650 Option ............... RPM AM6 .................. 651-700 AM7 .................. 701-750 AM8 .................. 751-800 AM9 .................. 801-850 AM10 ................ 851-900 AM11 ................ 901-950 AM12 ................ 951-1000 Option ............... RPM AM13 ................ 1001-1050 AM14 ................ 1051-1100 AM15 ................ 1101-1150 AM16 ................ 1151-1200 AM17 ................ 1201-1250 AM18 ................ 1251-1300 AM19 ................ 1301-1350 Option ............... RPM AM20 ................ 1351-1400 AM21 ................ 1401-1450 AM22 ................ 1451-1500 AM23 ................ 1501-1550 AM24 ................ 1551-1600 AM25 ................ 1601-1650 AM26 ................ 1651-1700 NOTE : Where 575V (AK8) is listed, the two corresponding AL option lines above apply to all other voltages with that HP. Model RDF 1-20 Open Motor HP Option AL4 AL4 1/2 AL4 AL4 AL5 AL5 AL5 3/4 AL5 AL5 AL5 AL6 AL6 AL6-AK8 AL6-AK8 1 AL6 AL6 AL6-AK8 AL6-AK8 AL7 AL7 AL7-AK8 AL7-AK8 AL7 AL7 1-1/2 AL7-AK8 AL7-AK8 AL7 AL7 AL7-AK8 AL7-AK8 2 Horz/Vert Discharge V H V H V H V H V H V H V H V H V H V H V H V H V H V H V H AL8 AL8 AL8 AL8 V H V H AL8 AL8 AL8 AL8 V H V H Form P-RDF, Page 24 CODE 200 - Motor CODE 201- Blower CODE Drive Option CODE 202 - Belt Sheave Sheave 203 (See table P/N Mfr No. Bore P/N Mfr No. Bore P/N Mfr No. Bushing above.) AM6-9 A52 7962 111607 50513 AK74 AM6-9 A43 7962 111607 50470 1VL40 5/8 3/4 AM10-15 A49 7962 105480 50475 AK54 AM10-15 7962 105480 105493 A39 AM8-11 A52 105476 111682 50513 AK71 1VL44 AM8-11 A43 105476 111682 50470 AM12-16 1VL40 A48 7962 105479 AK49 65403 5/8 3/4 AM12-16 105476 1VL44 A41 111684 AK59 50500 AM17-21 A50 13013 105480 88558 AK54 1VM50 AM17-21 A41 13013 105480 50500 AM10-15 A49 7962 105480 50475 5/8 AM10-15 7962 105480 105493 A39 AK54 1VL40 AM10-15 106748 A49 105480 50475 7/8 AM10-15 106748 105480 105493 A39 3/4 AM16-20 A51 13013 111684 65404 5/8 AM16-20 13013 111684 105493 A39 AK59 1VM50 AM16-20 37451 111684 105493 A39 7/8 AM16-20 A51 37451 111684 65404 AM10-15 A49 7962 105480 50475 5/8 AM10-15 7962 105480 105493 A39 1VL40 AK54 AM10-15 106748 A49 105480 50475 7/8 AM10-15 106748 105480 105493 A39 AM16-20 A51 13013 111684 65404 5/8 AM16-20 13013 111684 105493 A39 AK59 3/4 1VM50 AM16-20 37451 111684 105493 A39 7/8 AM16-20 A51 37451 111684 65404 AM21-24 1VL40 A47 7962 105478 AK41 50474 5/8 AM21-24 105487 16151 1VP56 110807 AK56H 101412 A42 AM21-24 106748 A47 105478 50474 AK41 1VL40 7/8 AM21-24 106748 105478 101412 A42 2 HP Drive Components for Model RDF 1-20 Series 3 only AM15-20 37451 111684 65404 A51 1VM50 AK59 AM15-20 37451 111684 105493 A39 7/8 3/4 AM21-24 106748 105478 50474 A47 1VL40 AK41 AM21-24 106748 105478 101412 A42 2 HP Drive Components for Model RDF 1-20 prior to Series 3 AM15-20 A51 13013 111684 65404 1VM50 AK59 AM15-20 13013 111684 105493 A39 5/8 3/4 AM21-24 1VL40 A47 7962 105478 50474 AK41 AM21-24 16151 1VP56 105478 101412 A42 Drive Components (cont'd) NOTE : Where 575V (AK8) is listed, the two corresponding AL option lines above apply to all other voltages with that HP. Model RDF 1-40 Open Motor HP Option AL5 AL5 AL5 3/4 AL5 AL5 AL5 AL6 AL6 AL6-AK8 AL6-AK8 1 AL6 AL6 AL6-AK8 AL6-AK8 AL7 AL7 AL7-AK8 AL7-AK8 AL7 AL7 1-1/2 AL7-AK8 AL7-AK8 AL7 AL7 AL7-AK8 AL7-AK8 2 3 5 CODE 200 - Motor CODE 201 - Blower Sheave Sheave P/N Mfr No. Bore P/N Mfr No. Bore AM4-6 7962 19111 AK84 AM4-6 7962 19111 1VL40 5/8 AM7-11 7962 18797 1 AK64 AM7-11 7962 18797 AM12-17 105476 105482 AK56 1VL44 7/8 AM12-17 105476 105482 AM7-11 7962 18797 5/8 AM7-11 7962 18797 AK64 1VL40 AM7-11 106748 18797 7/8 AM7-11 106748 18797 1 AM12-17 105476 105482 5/8 AM12-17 105476 105482 1VL44 AK56 AM12-17 106758 105482 7/8 AM12-17 106758 105482 AM7-11 7962 18797 5/8 AM7-11 7962 18797 AK64 1VL40 AM7-11 106748 18797 7/8 AM7-11 106748 18797 AM12-17 105476 105482 5/8 AM12-17 105476 105482 1 1VL44 AM12-17 106758 105482 7/8 AM12-17 106758 105482 AK56 AM18-21 13013 105482 5/8 AM18-21 13013 105482 1VM50 AM18-21 37451 105482 7/8 AM18-21 37451 105482 2 HP Drive Components for Model RDF 1-40 Series 3 only AM7-11 106748 18797 AK64 AM7-11 106748 18797 1VL40 AM12-17 106758 105482 7/8 1 AM12-17 106758 105482 AK56 AM18-21 37451 105482 1VM50 AM18-21 37451 105482 2 HP Drive Components for Model RDF 1-40 prior to Series 3 AM7-11 7962 18797 AK64 1VL40 AM7-11 7962 18797 AM12-17 105476 105482 5/8 1 1VL44 AM12-17 105476 105482 AK56 AM18-21 13013 105482 1VM50 AM18-21 13013 105482 AM12-17 106748 111609 AK99 AM12-17 106748 111609 1 1VL40 7/8 AM18-21 106748 19111 AK84 AM18-21 106748 19111 AM14-18 8973 30621 2AK124 AM14-18 8973 30621 1 2VP50 7/8 AM19-23 8973 7955 2AK104 AM19-23 8973 7955 Horz/Vert Drive Option Discharge (See page 23.) V H V H V H V H V H V H V H V H V H V H V H V H V H AL8 AL8 AL8 AL8 AL8 AL8 V H V H V H AL8 AL8 AL8 AL8 AL8 AL8 AL9 AL9 AL9 AL9 AL10 AL10 AL10 AL10 V H V H V H V H V H V H V H CODE 202 - Belt P/N Mfr No. A53 50513 A46 50473 A49 50475 101412 A42 A49 50475 101412 A42 A49 50475 101412 A42 A49 50475 101412 A42 A49 50475 101412 A42 A49 50475 101412 A42 A49 50475 101412 A42 A49 50475 101412 A42 A49 50475 101412 A42 A49 50475 101412 A42 A49 50475 A43 50470 A49 50475 A43 50470 50475 101412 50475 101412 50475 50470 A49 A42 A49 A42 A49 A43 50475 101412 50475 101412 50475 50470 16132 65403 50513 50473 50477 16131 16134 88558 A49 A42 A49 A42 A49 A43 A55 A48 A52 A46 A60 A54 A57 A50 Form P-RDF, Page 25 Drive Components (cont'd) NOTE : Where 575V (AK8) is listed, the two corresponding AL option lines above apply to all other voltages with that HP. Model RDF 1-50 Open Motor HP Option AL6 AL6 AL6-AK8 AL6-AK8 1 AL6 AL6 AL6-AK8 AL6-AK8 AL7 AL7 AL7-AK8 AL7-AK8 1-1/2 AL7 AL7 AL7-AK8 AL7-AK8 2 3 5 CODE 200 - Motor CODE 201- Blower Sheave Sheave P/N Mfr No. Bore P/N Mfr No. Bore AM4-6 7962 19111 5/8 AM4-6 7962 19111 AK84 1VL40 AM4-6 106748 19111 7/8 AM4-6 106748 19111 1 AM7-11 7962 18797 5/8 AM7-11 7962 18797 AK64 1VL40 AM7-11 106748 18797 7/8 AM7-11 106748 18797 AM4-6 7962 19111 5/8 AM4-6 7962 19111 1VL40 AK84 AM4-6 106748 19111 7/8 AM4-6 106748 19111 1 AM7-11 7962 18797 5/8 AM7-11 7962 18797 1VL40 AK64 AM7-11 106748 18797 7/8 AM7-11 106748 18797 2 HP Drive Components for Model RDF 1-50 Series 3 only AM4-6 106748 19111 AK84 AM4-6 106748 19111 1VL40 7/8 1 AM7-11 106748 18797 AK64 AM7-11 106748 18797 2 HP Drive Components for Model RDF 1-50 prior to Series 3 AM4-6 7962 19111 AK84 AM4-6 7962 19111 1VL40 5/8 1 AM7-11 7962 18797 AK64 AM7-11 7962 18797 AM8-11 106758 113372 1VL44 AK144 AM8-11 106758 113372 7/8 1 AM12-16 37451 50520 1VM50 AK134 AM12-16 37451 50520 AM8-13 87500 7955 2VP36 2AK104 AM8-13 87500 7955 7/8 1 AM14-18 8973 30621 2VP50 2AK124 AM14-18 8973 30621 Horz/Vert Drive Option Discharge (See page 23.) V H V H V H V H V H V H V H V H AL8 AL8 AL8 AL8 V H V H AL8 AL8 AL8 AL8 AL9 AL9 AL9 AL9 AL10 AL10 AL10 AL10 V H V H V H V H V H V H Form P-RDF, Page 26 CODE 202 - Belt P/N Mfr No. A50 88558 A46 50473 A50 88558 A46 50473 A47 50474 101412 A42 A47 50474 101412 A42 A50 88558 A46 50473 A50 88558 A46 50473 A47 50474 101412 A42 A47 50474 101412 A42 88558 50473 50474 101412 A50 A46 A47 A42 88558 50473 50474 101412 88560 50476 50477 16133 16130 50475 50476 16131 A50 A46 A47 A42 A61 A58 A60 A56 A53 A49 A58 A54 Drive Components (cont'd) NOTE : Where 575V (AK8) is listed, the two corresponding AL option lines above apply to all other voltages with that HP. Model RDF 1-65 Open Motor HP Option AL7 AL7 AL7-AK8 AL7-AK8 AL7 AL7 1-1/2 AL7-AK8 AL7-AK8 AL7 AL7 AL7-AK8 AL7-AK8 2 3 5 CODE 200 - Motor CODE 201- Blower Sheave Sheave P/N Mfr No. Bore P/N Mfr No. Bore AM2-3 13013 113372 5/8 AM2-3 13013 113372 1VM50 AK144 AM4-6 37451 113372 7/8 AM4-6 37451 113372 AM4-6 7962 19111 5/8 AM4-6 7962 19111 1 AK84 1VL40 AM4-6 106748 19111 7/8 AM4-6 106748 19111 AM7-11 7962 18797 5/8 AM7-11 7962 18797 AK64 1VL40 AM7-11 106748 18797 7/8 AM7-11 106748 18797 2 HP Drive Components for Model RDF 1-65 Series 3 only AM2-3 37451 113372 AK144 1VM50 AM2-3 37451 113372 AM4-6 106748 19111 1 7/8 AK84 AM4-6 106748 19111 1VL40 AM7-11 106748 18797 AK64 AM7-11 106748 18797 2 HP Drive Components for Model RDF 1-65 prior to Series 3 AM2-3 13013 113372 AK144 1VM50 AM2-3 13013 113372 AM4-6 7962 19111 5/8 1 AK84 AM4-6 7962 19111 1VL40 AM7-11 7962 18797 AK64 AM7-11 7962 18797 AM4-7 87500 113382 2VP36 AK144 AM4-7 87500 113382 1 7/8 AM8-11 6599 30622 2VP42 2AK134H AM8-11 6599 30622 AM7-13 87500 7955 2VP36 7/8 2AK104 1 AM7-13 87500 7955 Horz/Vert Drive Option Discharge (See page 23.) V H V H V H V H V H V H AL8 AL8 AL8 AL8 AL8 AL8 V H V H V H AL8 AL8 AL8 AL8 AL8 AL8 AL9 AL9 AL9 AL9 AL10 AL10 V H V H V H V H V H V H CODE 203 Mfr No. Bushing A61 A59 A61 A59 A49 A46 A49 A46 A45 A43 A45 A43 - CODE 202 - Belt P/N 88560 92402 88560 92403 50475 50473 50475 50473 50472 50470 50472 50470 88560 92403 50475 50473 50472 50470 A61 A59 A49 A46 A45 A43 - 88560 92403 50475 50473 50472 50470 92402 50476 50476 16133 65404 88558 A61 A59 A49 A46 A45 A43 A59 A58 A58 A56 A51 A50 92203 92203 - Form P-RDF, Page 27 Drive Components (cont'd) (Effective 8/90 all RDF-2-80 Models are equipped with a Class 2 blower. For RDF-2-80 with a Class 1 blower, see page 28. A Class 2 blower was available as a option prior to 8/90.) Model RDF 2-80 with a CLASS 2 BLOWER CODE 200 - Motor Sheave CODE 201 - Blower Sheave CODE 202 - Belt CODE 203 P/N Mfr No. Bore P/N Mfr No. Bore P/N Qty Mfr No. Bushing 2 HP Drive Components for Model RDF 2-80 Series 3 only AL8 V AM3-5 B55 106748 114026 112531 1 89659 1VL40 7/8 BK110H 1-7/16 AL8 H AM3-5 B53 106748 114026 92222 1 89659 2 2 HP Drive Components for Model RDF 2-80 prior to Series 3 AL8 V AM3-5 B55 7962 114026 112531 1 89659 1VL40 5/8 BK110H 1-7/16 AL8 H AM3-5 B53 7962 114026 92222 1 89659 AL9 V AM3-4 A69 87500 114027 16558 2 89659 2VP36 2AK184H AL9 H AM3-4 A67 87500 114027 16139 2 89659 AL9 V AM5-9 A59 110125 114028 92402 1 89659 7/8 3 1VP34 AK134H 1-7/16 AL9 H AM5-9 A57 110125 114028 16134 1 89659 AL9 V AM10-13 106748 A59 114030 92402 1 89659 1VL40 AK124H AL9 H AM10-13 106748 A55 114030 16132 1 89659 AL10 V AM3-4 A69 87500 114027 16558 2 89659 2AK184H 2VP36 AL10 H AM3-4 A67 87500 114027 16139 2 89659 AL10 V AM5-6 BX65 87500 114032 2B5V160 92276 2 114033 7/8 1-7/16 5 AL10 H AM5-6 2VP42 A67 6599 114027 2AK184H 16139 2 89659 AL10 V AM7-11 A58 87500 114034 50476 2 89659 2VP36 2AK124H H AM7-11 A55 AL10 87500 114034 16132 2 89659 AL11 V AM6-7 2VP68 B66 113802 89651 114104 2 89659 2BK16 0H AL11 H AM6-7 2VP71 B64 114249 89651 92414 2 89659 AL11 V AM8-9 B58 106257 113811 92226 2 89659 2VP60 2BK120H AL11 H AM8-9 B56 106257 113811 92224 2 89659 1-3/8 1-7/16 7-1/2 AL11 V AM10-11 BX59 16150 114045 92280 2 114033 2VP62 2BV110 AL11 H AM10-11 BX55 16150 114045 92409 2 114033 AL11 V AM12-15 106257 B53 113804 92222 2 89659 2VP60 2BK90H AL11 H AM12-15 106257 B51 113804 92220 2 89659 AL12 V AM6-7 2VP68 B66 113802 89651 114104 2 89659 2BK16 0H AL12 H AM6-7 2VP71 B64 114249 89651 92414 2 89659 AL12 V AM8-9 B58 106257 113811 92226 2 89659 2BK120H 2VP60 AL12 H AM8-9 B56 106257 113811 92224 2 89659 1-7/16 1-3/8 10 AL12 V AM10-11 BX59 16150 114045 92280 2 114033 2BV110 2VP62 AL12 H AM10-11 BX55 16150 114045 92409 2 114033 AL12 V AM12-15 106257 B53 113804 92222 2 89659 2BK90H 2VP60 AL12 H AM12-15 106257 B51 113804 92220 2 89659 AL15 V AM7-9 BX55 91615 2MVP40B54 113811 2BK120H 92409 2 89659 AL15 H AM7-9 B59 113809 92204 2BK140H 16143 2 89659 2VP71A AL15 V AM10-11 113809 B58 89650 92226 2 89659 2BK130H AL15 H AM10-11 113809 B57 89650 92225 2 89659 1-5/8 1-7/16 15 AL15 V AM12-16 114047 BX50 114033 114048 92236 2 2MVP45B59 AL15 H AM12-16 114047 B49 114048 113805 2 114033 2B5V86 AL15 V AM17-20 113808 BX53 114048 114341 2 114033 2VP75 AL15 H AM17-20 113808 BX51 114048 92237 2 114033 CODE 202 - Belt CODE 203 TEFC Motor Horz/Vert Drive Option CODE 200 - Motor Sheave CODE 201 - Blower Sheave HP Option Discharge (See page 23.) P/N Mfr No. Bore P/N Mfr No. Bore P/N Qty Mfr No. Bushing AL27 H AM7-9 1VP50 1-1/8 113799 AK184H 1-7/16 16139 2 A67 5 111681 89659 NOTE: If drive components are required for units with a TEFC or Premium Efficiency motor not listed here, contact your Distributor or the Factory Service Department. Be prepared to provide complete Model and Serial No. Open Motor Horz/Vert Drive Option HP Option Discharge (See page 23.) Form P-RDF, Page 28 Drive Components (cont'd) Model RDF-2-80 with a Class 1 Blower (Effective 8/90 all RDF-2-80 Models are equipped with a Class 2 blower. For RDF-2-890 with a Class 2 blower, see page 27. A Class 2 blower was available as a option prior to 8/90. Form P-RDF, Page 29 Drive Components (cont'd) Model RDF 2-120 * Open Motor Horz/Vert Drive Option CODE 200 - Motor Sheave CODE 201 - Blower Sheave CODE 202 - Belt CODE 203 HP Option Discharge (See page 23.) P/N Mfr No. Bore P/N Mfr No. Bore P/N Qty Mfr No. - Bushing 2 HP Drive Components for Model RDF 2-120 Series 3 only AL8 V AM3-5 1VL44 A53 106758 113798 AK104H 16130 1 89659 7/8 1-7/16 AL8 H AM3-5 1VL40 B54 106748 114026 BK110H 92223 1 89659 2 2 HP Drive Components for Model RDF 2-120 prior to Series 3 AL8 V AM3-5 1VL44 A53 105476 113798 AK104H 16130 1 89659 1-7/16 5/8 AL8 H AM3-5 1VL40 B54 7962 114026 BK110H 92223 1 89659 AL9 V AM3-4 2BK10H BX68 87500 89652 92241 2 89659 2VP36 AL9 H AM3-4 A69 87500 114027 2AK184H 16558 2 89659 AL9 V AM5-7 1VL44 A69 106758 113799 AK184H 16558 1 89659 7/8 1-7/16 3 AL9 H AM5-7 1VP34 A59 110125 114028 AK134H 92402 1 89659 AL9 V AM8-11 A61 106758 113800 AK144H 88560 1 89659 1VL44 AL9 H AM8-11 A63 106758 113800 AK144H 16138 1 89659 AL10 V AM3-4 2BK10H BX68 87500 89652 92241 2 89659 2VP36 AL10 H AM3-4 A69 87500 114027 2AK184H 16558 2 89659 AL10 V AM5-7 BK160H BX62 87500 89651 92411 2 89659 7/8 1-7/16 5 AL10 H AM5-7 2VP42 A70 6599 114027 2AK184H 114257 2 89659 AL10 V AM8-11 A53 87500 113801 2AK104H 16130 2 89659 2VP36 AL10 H AM8-11 A57 87500 114034 2AK124H 16134 2 89659 AL11 V AM4-5 BX64 110771 114032 2B5V160 114258 2 114033 2VP65 AL11 H AM4-5 BX67 110771 114032 2B5V160 80841 2 114033 AL11 V AM6-7 2VP68 BX63 113802 89651 2BK160H 92278 2 89659 AL11 H AM6-7 2VP71 B66 114249 89651 2BK160H 114104 2 89659 1-3/8 1-7/16 7-1/2 AL11 V AM8-11 B54 106257 113803 2BK110H 92223 2 89659 AL11 H AM8-11 B56 106257 113803 2BK110H 92224 2 89659 2VP60 AL11 V AM12-15 106257 B50 113804 2BK90H 114010 2 89659 AL11 H AM12-15 106257 B53 113804 2BK90H 92222 2 89659 AL12 V AM4-5 BX64 110771 114032 2B5V160 114258 2 114033 2VP65 AL12 H AM4-5 BX67 110771 114032 2B5V160 80841 2 114033 AL12 V AM6-7 2VP68 BX63 113802 89651 2BK160H 92278 2 89659 AL12 H AM6-7 2VP71 B66 114249 89651 2BK160H 114104 2 89659 1-3/8 1-7/16 10 AL12 V AM8-11 B54 106257 113803 2BK110H 92223 2 89659 AL12 H AM8-11 B56 106257 113803 2BK110H 92224 2 89659 2VP60 AL12 V AM12-15 106257 B50 113804 2BK90H 114010 2 89659 AL12 H AM12-15 106257 B53 113804 2BK90H 92222 2 89659 AL15 V AM6-7 2VP75 BX62 113808 114032 2B5V160 92411 2 114033 AL15 H AM6-7 BX55 91615 2MVP40B54 113811 2BK120H 92409 2 89659 AL15 V AM8-9 2VP71A B58 113809 92204 2BK140H 92226 2 89659 AL15 H AM8-9 BX55 91615 2MVP40B54 113811 2BK120H 92409 2 89659 1-5/8 1-7/16 15 AL15 V AM10-11 113808 2VP75 B56 89650 92224 2 89659 2BK130H AL15 H AM10-11 113809 2VP71A B59 89650 16143 2 89659 AL15 V AM12-13 113808 B55 113811 112531 2 89659 2VP75 2BK120H AL15 H AM12-13 113808 B58 113811 92226 2 89659 * If drive components are required for units with a 3-10HP TEFC or 3-10 HP Premium Efficiency motor, contact your Distributor or the Factory Service Department. Be prepared to provide complete Model and Serial No. Form P-RDF, Page 30 Drive Components (cont'd) Model RDF 3-180 *Open Motor Blower Horz/Vert Drive Option HP Option Class Discharge (See page 23.) AL10 1 V AM2-3 AL10 1 V AM4-5 5 AL10 1 H AM2-3 AL10 1 H AM4-5 AL11/12 1 V AM1 AL11/12 1 V AM2 AL11/12 1 V AM3 AL11/12 1 V AM4-5 1 V AM6-7 7-1/2 AL11/12 AL11/12 1 V AM8-9 and AL11/12 1 H AM1 10 AL11/12 1 H AM2 AL11/12 1 H AM3 AL11/12 1 H AM4-5 AL11/12 1 H AM6-7 AL11/12 1 H AM8-9 AL15/16 1 V AM4-5 AL15/16 1 V AM6-7 AL15/16 1 V AM8-10 AL15/16 1 V AM11-14 AL15/16 2 V AM2-3 AL15/16 2 V AM4-6 AL15/16 2 V AM7-9 2 V AM10-12 15 AL15/16 AL15/16 2 V AM13-15 and AL15/16 1 H AM4-5 20 AL15/16 1 H AM6-7 AL15/16 1 H AM8-10 AL15/16 1 H AM11-14 AL15/16 2 H AM2-3 AL15/16 2 H AM4-6 AL15/16 2 H AM7-9 AL15/16 2 H AM10-12 AL15/16 2 H AM13-15 AL17/18 2 V AM5-6 AL17/18 2 V AM7-9 AL17/18 2 V AM10-12 25 AL17/18 2 V AM13-16 and AL17/18 2 H AM5-6 30 AL17/18 2 H AM7-9 AL17/18 2 H AM10-12 AL17/18 2 H AM13-16 CODE 200 - Motor Sheave P/N Mfr No. Bore 2VP42 6599 87500 2VP36 7/8 2VP42 6599 87500 2VP36 2VP71 114249 2VP60 106257 2VP62 16150 2VP65 110771 2VP71 114249 106257 2VP60 1-3/8 2VP71 114249 2VP60 106257 2VP62 16150 2VP65 110771 2VP71 114249 106257 2VP60 89644 3MVP40B54 115719 3MVP50B64 89645 3MVP45B59 89644 3MVP40B54 89645 3MVP45B59 89644 3MVP40B54 89644 115719 3MVP50B64 89645 3MVP45B59 1-5/8 89644 3MVP40B54 115719 3MVP50B64 89645 3MVP45B59 89644 3MVP40B54 89645 3MVP45B59 89644 3MVP40B54 89644 115719 3MVP50B64 89645 3MVP45B59 115931 4MVP50B64 115946 4MVP45B59 115931 4MVP50B64 115931 4MVP50B64 1-7/8 115931 4MVP50B64 115946 4MVP45B59 115931 4MVP50B64 115931 4MVP50B64 CODE 201- Blower Sheave P/N Mfr No. Bore 115718 2B5V250 89652 2BK190H 1-7/16 115718 2B5V250 89652 2BK190H 115718 2B5V250 89652 2BK190H 89652 114032 2B5V160 114032 113811 2BK120H 1-7/16 115718 2B5V250 89652 2BK190H 89652 114032 2B5V160 89651 113811 2BK120H 115720 3B5V136 115721 3B5V154 1-7/16 115722 3BK120H 3BK90H 115723 115943 3B5V184 115720 3B5V136 2-3/16 115935 3B5V110 115935 3B6V90 115945 115720 3B5V136 115721 3B5V154 1-7/16 115722 3BK120H 3BK90H 115723 115943 3B5V184 115720 3B5V136 2-3/16 115935 3B5V110 115935 3B6V90 115945 116204 4MVB154R 116203 4MVB124R 116202 4MVB110R 116201 4MVB94Q 2-3/16 116204 4MVB154R 116203 4MVB124R 116202 4MVB110R 116201 4MVB94Q CODE 202 - Belt CODE 203 P/N Qty Mfr No. - Bushing BX97 92319 2 114033 B86 92312 2 89659 B92 92308 2 114033 BX77 92341 2 89659 BX99 115932 2 114033 B88 115933 2 89659 B89 115934 2 89659 B84 92273 2 114033 BX85 92317 2 114033 BX75 92277 2 89659 BX93 92313 2 114033 BX79 92332 2 89659 BX79 92332 2 89659 BX75 92277 2 114033 BX75 92277 2 89659 BX66 92240 2 89659 BX77 92341 3 114033 BX81 92274 3 114033 B74 92231 3 89659 BX68 92241 3 89659 B87 92310 3 116205 BX77 92341 3 116205 B73 92230 3 116205 BX75 92277 3 116205 BX71 92243 3 116205 BX68 92241 3 114033 B73 92230 3 114033 3 B65 6010 89659 B59 16143 3 89659 B78 92234 3 116205 BX68 92241 3 116205 BX64 114258 3 116205 BX65 92276 3 116205 BX62 92411 3 116205 BX80 92412 4 116206 BX72 92277 4 116206 B73 92230 4 116206 BX70 92242 4 116207 BX71 92243 4 116206 BX65 92276 4 116206 BX63 92278 4 116206 BX61 92289 4 116207 * If drive components are required for units with a 5-15HP TEFC or 5-15 HP Premium Efficiency motor, contact your Distributor or the Factory Service Department. Be prepared to provide complete Model and Serial No. Form P-RDF, Page 31 Drive Components (cont'd) Model RDF 3-260 *Open Motor Blower Horz/Vert Drive Option HP Option Class Discharge (See page 23.) AL11/12 1 H AMA3 AL11/12 1 V AMA3 AL11/12 1 H AMA4 7-1/2 AL11/12 1 V AMA4 and 10 AL11/12 1 H AM1-2 AL11/12 1 V AM1-2 AL11/12 1 H AM3-4 AL11/12 1 V AM3-4 AL15/16 1 H AMA4 AL15/16 1 V AMA4 AL15/16 1 H AM1 AL15/16 1 V AM1 AL15/16 1 H AM2 AL15/16 1 V AM2 AL15/16 1 H AM3-5 1 V AM3-5 15 and AL15/16 20 AL15/16 2 H AMA4 AL15/16 2 V AMA4 AL15/16 2 H AM1 AL15/16 2 V AM1 AL15/16 2 H AM2-3 AL15/16 2 V AM2-3 AL15/16 2 H AM4-6 AL15/16 2 V AM4-6 AL17/18 2 H AM1 AL17/18 2 V AM1 AL17/18 2 H AM2-3 25 and AL17/18 2 V AM2-3 30 AL17/18 2 H AM4-5 AL17/18 2 V AM4-5 AL17/18 2 H AM6-8 AL17/18 2 V AM6-8 CODE 200 - Motor Sheave P/N Mfr No. Bore 115940 2MVP35B49 115940 106257 2VP60 106257 1-3/8 89641 2MVP40B54 89641 106257 2VP60 106257 89644 3MVP40B54 89644 115719 3MVP50B54 115719 1-5/8 89644 89644 3MVP40B54 89644 89644 89645 3MVP45B59 89645 89644 3MVP40B54 89644 1-5/8 89645 3MVP45B59 89645 89644 3MVP40B54 89644 116460 4MVP55B69 116460 115946 115946 4MVP45B59 1-7/8 115946 115946 116460 4MVP55B69 116460 CODE 201- Blower Sheave P/N Mfr No. Bore 115941 115941 2B5V234 115941 115941 1-11/16 115942 2B5V184 115942 114032 2B5V160 114032 115944 115944 3B5V234 115944 115944 1-11/16 115943 3B5V184 115943 115721 3B5V154 115721 116446 3MVB250R 116446 116447 3MVB200R 116447 2-11/16 116448 3MVB184Q 116448 116449 3MVB136Q 116449 116461 4MVB250R 116461 116462 4MVB184R 116462 2-11/16 116204 116204 4MVB154R 116204 116204 CODE 202 - Belt P/N Qty Mfr No. 2 BX103 92316 2 BX113 115947 2 BX103 92316 2 BX115 115948 2 BX93 92313 2 BX105 92314 2 BX90 92315 2 BX103 92316 3 BX100 92318 3 BX113 115947 3 B101 115865 3 BX113 115947 3 BX90 92315 3 BX103 92316 3 B84 92273 3 BX97 92319 3 BX103 92316 3 BX115 115948 3 BX93 92313 3 BX105 92314 3 BX90 92315 3 BX103 92316 3 BX81 92274 3 B94 119610 4 BX103 92316 4 BX115 115948 4 BX90 92315 4 BX103 92316 4 BX83 92333 4 BX96 92334 4 BX85 92317 4 BX97 92319 CODE 203 Bushing 115949 115949 115949 115949 115949 115949 115949 115949 115949 115949 115949 115949 115949 115949 115949 115949 116451 116451 116451 116451 91609 91609 91609 91609 116451 116451 116451 116451 116451 116451 116451 116451 * If drive components are required for units with a 7-1/2 - 20 HP TEFC or 7-1/2 - 20 HP Premium Efficiency motor, contact your Distributor or the Factory Service Department. Be prepared to provide complete Model and Serial No. Form P-RDF, Page 32 Cabinet Parts for Models RDF-1 Series 3 Optional Return Air Opening 222 226 234 226 Bottom Discharge Outside Air Opening 223 232 220 221 Rear View Top View 231 Control Compartment 228 229 Blower Compartment 227 230 Supply Wiring 24V Wiring Gas Supply Control Side Horizontal Discharge 225 235 CODE Description 220 221 222 223 224A 224B 225 226 227 228 228A 229 230 231 232 233 234 235 236 237 224 Top Front Top Rear Top Clamp Inlet Screen (Standard unit without optional inlet air hood or filter cabinet) Front Panel Assembly including Duct Assembly for Horizontal discharge Front Panel Assembly for unit with bottom discharge (includes insulation) Motor Access Panel Assembly - Horizontal Discharge Only Side Panel Assembly (includes insulation) Front Panel Assembly for unit with bottom discharge (includes insulation) Burner/Control Door Assembly Positioning Hinge (Part of CODE 228) Blower Section Door Assembly Center Post Outer Cover Front Corner Post Outer Cover Left Rear Corner Post Outer Cover Right Rear Corner Post Outer Cover Intermediate Post Cover Vertical Discharge Cover (hoizontal discharge only) Pilot Access Cover Assembly Door Latch Front View Model RDF Series 3 1-20 1-40 1-50 1-65 86879 86880 86882 96817 N/A N/A 87685 86848 94360 86848 86848 204476 158800 90321 86868 (2) 86865 203816 203817 203815 203994 204474 124067 Form P-RDF, Page 33 Cabinet Parts for Models RDF-2 and RDF-3 Series 3 244 Optional Return Air Opening (F x G) 253 253 245 245 243 Bottom Discharge 242 241 Outside Air Opening 255 254 240 Rear View Top View Control Compartment 247 246 251 252 24V Wiring Supply Wiring Gas Supply Control Side Blower Compartment 245 256 Top Front Top Center Top Rear Top Clamp Right Rear Side Door Assembly Side Door Assembly Front Burner/Control Door Assembly Rear Burner/Control Door Assembly Positioning Hinge (Part of CODE 247) Front Panel Assembly including Duct Assembly for Horizontal Discharge Front Panel Assembly - Bottom Discharge Left Front Corner Post Outer Cover Right Front Corner Post Outer Cover Intermediate Post (Control) Intermediate Post Outer Cover #1 Intermediate Post Outer Cover #2 Left Rear Corner Post Outer Cover Right Rear Corner Post Outer Cover Vertical Discharge Cover (horizontal discharge only) Pilot Access Cover Door Latch Form P-RDF, Page 34 249 248 CODE Description 240 241 242 243 244 245 246 247 247A 248A 248B 249 250 251 252 253 254 255 256 257 258 Horizontal Discharge Front View Model RDF 2-80 2-120 3-180 3-260 89558 91172 N/A 91173 89559 91174 89562 (2) 91179 203745 204558 (2)89510 (3) 91116 204498 204559 204497 204560 158800 89519 91125 89967 91212 89547 91157 89547 91158 203729 203639 89552 204536 (2) 91163 N/A 203728 203646 203736 203644 203982 204538 204474 203876 124067 250 CODE 270 - Screened Air Inlet Hoods for Outdoor Units and Filter Sections for Indoor Units Description 100% Outside Air Inlet Hood (Same as Option AS2) 100% Outside Air Inlet Hood with Integral Filter Rack & 1" Permanent Filters (Same as Option AS6) 100% Outside Air Inlet Hood with Integral Filter Rack & 2" Permanent Filters (Same as Option AS7) Outside Air Filter Section for Indoor Units with 1" Filters (Same as Option AW3) Outside Air Filter Section for Indoor Units with 2" Filters (Same as Option AW6) Components - Outdoor Screened Air Inlet Cabinets for Models RDF-3 only RDF-1 69594 69596 72623 69597 72624 RDF-2 68774 68739 72625 68775 72626 Pkg P/N 71150 Pkg P/N 71152 Pkg P/N 72627 Same as Option AS2 Same as Option AS6 Same as Option AS7 Qty Top of Inlet Hood Cabinet Section 1 Top of Inlet Hood 1 Clamp for Top Seam (Hood to Cabinet) 1 Bottom of Hood Cabinet Section 1 Supports (2 pieces per leg) 6 Left Side of Hood 1 Right Side of Hood 1 Intermediate Posts - Cabinet Section 2 Right Corner Posts - Cabinet Section 1 Left Corner Post - Cabinet Section 1 Doors (Filter Access Section on AS6 and AS7) 2 Center Louver Top/Bottom Supports 2 Pre-assembled Louver Sections with Screens 2 Top and Bottom Filter channels Filter Block Off Plates Bottom Filter block Off Plate Filter Block off Sections Permanent Filters P/N 91575 91576 91577 91567 91581 91568 91569 91578 91579 91579 91585 91582 113003 N/A N/A N/A N/A N/A Qty 1 1 1 1 6 1 1 2 1 1 2 2 2 2 2 6 12 P/N 91575 91576 91577 91567 91581 91568 91569 91578 91579 91579 91585 91582 113003 91580 91584 N/A 95335 87251, 12x35x1 RDF-3 71150 71152 72627 71153 72628 Qty 1 1 1 1 6 1 1 2 1 1 2 2 2 2 P/N 91575 91576 91577 91567 91581 91568 91569 91578 91579 91579 91585 91582 113003 94224 N/A 1 98764 6 95335 10 94383, 12x35x2 Hardware included in all of the above packages: Qty P/N Description 100 11813 Sheetmetal Screws #10 x 1/2" long 15 10393 Screws 1/4-10 x 5/8" long (bolt type) - for legs and top clamp 15 7328 Hex Locking Nuts 1/4-20 - for legs and top clamp 3 41463 Sheetmetal Screws #14-10 x 3/4" long - for attaching legs 5 87900 Tinnerman Clips, Palnut #PW-1880-008-21 - for joining louver sections 4 37661 Screws, #10 x 1/2" long (self-drilling) - for attaching middle of doors) CODE 280 - Roof Curb Packages and Components Each roof curb package for a Model RDF system includes two curb sides, one front, one back, eight curb dividers for creating supply and return air ductwork in the curb, and hardware for corner assembly and for installing ductwork dividers. Roof Curb Option CJ3 for Model RDF Series 3 (See illustration, page 36) RDF S eries 3 RDF-1 RDF-2 RDF-3 Pkg P/N 2 Curb S ide 1 Curb Front Assembly and Back Assy 3 , 4 , and 5 - Curb Dividers for Ductwork 204368 (2)204365 (2)104655 (4)203803 (2)203804 (2)203806 203980 204370 (2)204366 (2)204369 (2)111508 (2)111512 (4)203977 (2)203978 (2)203979 (4)203662 (2)203663 (2)203664 Roof Curb Corner Hardware For Top Two 8 5/16" x 1" Lag Screws, P/N 16243 8 5/16" Lockwasher, P/N 1333 "Holes" 8 5/16" x 3/4" Hex Head Cap Screw, For Bottom P/N 16247 Two "Holes" 8 5/16" Lockwasher, P/N 1333 8 5/16-18 Hex Nut, P/N 1035 Hardware to Assemble and Attach Dividers to make Ductwork Openings 64 #10 Sheetmetal Screws, P/N 11813 Form P-RDF, Page 35 Roof Curb Packages and Components (cont'd) Model RDF Series 3 - Reznor Roof Curb and Duct Opening Dimensions -1 -2 -3 Dimensions of Roof Curb Option CJ3 inches mm inches mm inches mm A 84-5/8 2149 84-5/8 2149 131-3/4 3346 B 43-5/8 1108 67-9/16 1716 82-1/16 2084 128 3251 C** 80-7/8 2054 80-7/8 2054 D** 39-7/8 1013 63-13/16 1621 78-5/16 1989 ** C and D are roof opening dimensions if curb area is fully open. 1-7/8 (48) Roof Curb Ductwork for Optional Return Air RDF IMPORTANT NOTE: Area enclosed by roof curb must comply with clearance to combustible materials. If the roof is constructed of combustible materials, area within the roof curb must be ventilated; left open, or 1-7/8 covered with non-combustible material which (48) has an "R" value of at least 5. If area within curb is left open, higher radiated sound levels may result. Roof Curb Duct Opening Dimensions E F G Sizes 5 inches 23-11/32 20-1/8 RDF-1 593 511 127 mm inches 28-13/32 28-11/32 13-15/32 RDF-2 722 720 342 mm 38 38 11-19/32 inches RDF-3 965 965 294 mm NOTES: • Drawings are not proportional for all sizes. • 3/4" (19mm) measurement is the width of the flanges where the roof curb mates with the heater. Surface of flanges must be sealed. • When cutting duct openings in the roof, cut opening 1” (25mm) larger than duct size opening for installation clearance. H 10-1/4 260 7 178 4-5/8 117 Top View Roof Curb Ductwork for Bottom Discharge (Option AQ1 or AQ3) Airflow D B (See IMPORTANT NOTE.) A C J K M 25-1/2 11-1/2 11-15/32 648 292 291 54-11/16 17-23/32 8 1389 432 203 66-3/4 20-1/16 10-15/32 1695 510 266 N 1-7/8 (48) N 11-1/32 280 11-3/32 282 17-1/4 438 F K H G J Return Air Opening (J x K) Top View Airflow 3/4 (19) Bottom Discharge Supply Air Opening (E x F) E 3/4 (19) M Assembled Dividers for Optional Return Air Ductwork in the Roof Curb Field-supplied ductwork may be either dropped in from the top resting on the top flange or be attached to the bottom flange, using the dividers as ductwork. (800) 695-1901; www.RezSpec.com Form P-RDF, Page 36 ©2005 Thomas & Betts Corporation, All rights reserved. Printed in U.S.A. MANUFACTURER OF GAS, OIL, ELECTRIC HEATING AND VENTILATING SYSTEMS 9/05 Form P-RDF (Version A.1)
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Create Date : 2005:09:02 14:12:15-04:00 Subject : P-RDF Version A.1 Author : REAGLKC Modify Date : 2005:09:02 14:12:40-03:00 XMP Toolkit : 3.1-701 Producer : Acrobat Distiller 7.0 (Windows) Keywords : Creator Tool : Adobe PageMaker 7.0 Format : application/pdf Title : P-RDF Version A.1 Creator : REAGLKC Description : P-RDF Version A.1 Document ID : uuid:21c91c46-5904-4b2e-98aa-7a0baad483bd Instance ID : uuid:545e1ca6-1f47-4f2c-afef-73dc2a30e4a8 Page Count : 36EXIF Metadata provided by EXIF.tools