75438_1 ENG 101006 Catalog
2014-07-30
: Pdf 101006-Catalog 101006-Catalog 786210 Batch6 unilog
Open the PDF directly: View PDF .
Page Count: 176
Download | |
Open PDF In Browser | View PDF |
T&B Conduit Fittings Table of Contents General Information Rigid and Intermediate Metal Conduit Fittings Specifications for Rigid Metal Conduit Locknuts, Sealing Fittings, Bonding and Grounding Wedges 4 5-53 5-10 11, 12 Bushings 13-19 Knockout Plugs 20–21 Chase ® Nipple 22-2222-23 Threaded Bullet ® Hubs 24-27 T&B Hub 28-31 Threadless Fittings/Couplings 32-34 Set Screw Fittings/Couplings 35, 36 Short Elbows 37 Erickson ® Threaded Couplings 38-40 Conduit Straps and Spacers 41-44 Combination Couplings, Beam Clamps, Conduit Supports Methods of Bonding and Grounding Electrical Metal Tubing (EMT) Fittings 45 46-53 54-59 Specifications for EMT 54-56 EMT Fittings 57-59 Flexible Cord and Cable Fittings 60-82 Specifications for Flexible Cord and Cable 60-62 Selection Guide 63, 64 Specifications for Liquidtight Flexible Cord and Cable Fittings Strain Relief Fittings Ranger Series Liquidtight Strain Relief Fittings ™ Aluminum Liquidtight Strain Relief Fittings SS Liquidtight Conduit Connectors 65 66-69 70, 71, 73, 75 72 74 Silver Grip™ — TCF ™ Series Tray-Cord Fitting 76, 77 Silver Grip™ Liquidtight Fittings 78, 79 iremesh Grips 80 Nonmetallic Cable Glands 81 Metric Adapters, Fittings and Plug 82 2 T&B Conduit Fittings Table of Contents Service Entrance Cable Fittings 83-87 Specifications 83-85 Service Entrance Cable Fittings 86, 87 Liquidtight Flexible Conduit Fittings Specifications for Liquidtight Flexible Metal Conduit 88-110 88-90 High Temperature Flexible Metal Liquidtight Fittings 91 Liquidtight Flexible Metal Conduit Fittings 92-100, 103-106, 109 Specifications — Type A Nonmetallic Conduit Fittings Liquidtight Flexible Nonmetallic Conduit Fittings ISO Metric BulletTM Liquidtight Fittings Armoured Cable and Flexible Metal Conduit Fittings 101 101, 102, 107, 108 110 111-119 Specifications for Armoured Cable and Flexible Metal Conduit 111-114 Fittings for Armoured Cable and Flexible Metal Conduit 115-119 Nonmetallic Sheathed Cable Fittings 120-126 Specifications for Nonmetallic Sheathed Cable Fittings 120, 121 Fittings for Nonmetallic Sheathed Cable Fittings 122, 126 Liquatite ® Flexible Conduit 127-155 127,128 Application Guide Steel 129-135, 137, 139 142, 144, 145 Aluminum 136, 138, 143 Shielding 140, 141 Nonmetallic 146, 147 Corrlok System 148-152 Engineering Information 153, 154 ® Packaging 155 Conduit Dimensional Data 156, 157 Conduit Chemical Resistance Guide 158-161 Alphanumeric Index 162-175 T&B Conduit Fittings General Information Thomas & Betts… The Complete Product Line Since the turn of the century, Thomas & Betts has been a recognized leader in electrical fittings. Industry standards such as Chase® Nipples and Erickson® Couplings were introduced by Thomas & Betts and are still registered trademarks. This leadership continues. Here’s why. Innovative Designs The real test of product design of electrical fittings lies in two areas: jobsuited installation and life-of-the-job reliability. Thomas & Betts Fittings provide both because we listen. We listen to problems and suggestions from the field. Most of the products in this section result from the good suggestions of knowledgeable electrical people. Many were custom designed to solve a customer’s particular installation and performance problems. You can benefit from their experience. Approvals and Certifications Electrical raceways require accessory fittings that provide the mechanical strength, ground continuity, and environmental integrity of the system. As new raceways have been introduced, Thomas & Betts, engineers have designed fittings which meet the requirements of the Canadian Electrical Code, as well as the Canadian Standards Association. You can use Thomas & Betts Fittings with confidence. Note: All dimensions in this catalogue are approximate. 4 High Performance Products Quality and performance result when engineering design skills are combined with the manufacturing technologies required to produce them. The Thomas & Betts Fittings in this section are produced from many materials and by many manufacturing methods, each carefully selected for its end use suitability. This combination gives you the reliable performance you expect from Thomas & Betts Raceway Fittings. Lower Installed Cost Lower installed cost is a function of purchase cost, availability, installation advantage, and performance; it comes in every carton of Thomas & Betts Raceway Fittings. T&B Conduit Fittings Rigid Metal Conduit Fittings Specifications — Rigid Metal Conduit/PVC Coated Rigid Metal Conduit Ref. CEC Rule 12-1000 Rigid Metal Conduit affords maximum mechanical protection to conductors within the raceway. Rigid metal conduit can be installed indoors and outdoors, in dry locations or wet locations, exposed or concealed, in all atmospheric conditions and in hazardous locations. Galvanized rigid steel conduit installed in concrete does not require supplementary corrosion protection. Galvanized rigid steel conduit, installed in contact with soil, does not generally require supplementary corrosion protection. However, when buried in corrosive soil (corrosive soil is characterized by low resistivity of less than 2,000 ohm-centimeter) or cinders, a protective coating of bitumastic, asphaltbased paint or a PVC coating is applied to the conduit. CEC Rule 12-934 requires that rigid steel conduit installed in or under permanently moist cinder fill be encased in at least two inches of cinder-free concrete unless the conduit is at least 18 inches below the fill. Steel conduit protected from corrosion solely by enamel can only be used indoors and in occupancies not subjected to severe corrosive influences. Rigid nonferrous metal conduit (aluminum) cannot be directly embedded in concrete containing soluble chlorides such as calcium chloride; unwashed beach sand, seawater, or coral bearing aggregates. However, if adequately treated by a protective coating of bitumastic or asphalt-based paint or PVC coating, the conduit can be installed in concrete containing chlorides. Supplementary nonmetallic coatings presently used on ferrous rigid metal or nonferrous metal have not been investigated for resistance to corrosion. CEC Rule 12-920 requires that when conduit enters a box or fitting, a bushing must be provided to protect wires from abrasion unless the design of the box or fitting provides equivalent protection. According to CEC Rule 12-906 where No. 8 or larger ungrounded conductors enter or leave a conduit, an insulating bushing with a smooth well rounded insulating surface must be provided to protect conductors unless the terminating fitting is equipped with an insulated throat, firmly secured in place providing equivalent protection. The insulating bushing or insulating material must have a temperature rating of not less than the insulation temperature rating of installed conductors. When conduit bushings are constructed wholly of insulating material, a locknut must be installed both inside and outside of the enclosure to which the conduit is attached. Fittings and couplings are required to be of concrete-tight type when embedded in masonry or concrete or in dry locations and of the raintight type when installed in wet locations. In wet locations or locations where walls are frequently washed or where there are surfaces of absorbent materials, the entire wiring system including boxes, fittings, conduit and cables must be supported such that there is at least 1/4 inch air space between it and the supporting surface (CEC Rule 2-122). CEC Rule 12-3022 requires that the raceways be metallically joined together into a continuous electric conductor and must be mechanically connected to all boxes, fittings and cabinets as to provide effective electrical continuity. Conduit is required to be supported adequately and conduit bends in one run are restricted to the equivalent of four quarter i.e. 360 degrees total. 5 Listed below are some of the advantages of rigid aluminum conduit over rigid steel conduit. 1. Non-sparking—eliminates hazard in explosive atmospheres 2. Non-magnetic—reduces power loss due to voltage drop 3. Resists most corrosive atmospheres and industrial environments 4. Lightweight—reduces cost of handling and installation 5. Attractive appearance T&B Conduit Fittings Rigid Metal Conduit Fittings Specifications —Rigid Metal Conduit/PVC Coated Rigid Metal Conduit (continued) For further details and complete information please refer to the following: 1. ANSI C80.1…Rigid Steel Conduit Zinc Coated, Specifications for 2. ANSI C80.2…Rigid Steel Conduit, Enameled, Specifications for 3. ANSI C80.5…Rigid Aluminum Conduit. Specifications for 4. ANSI C80.4…Fittings for Rigid Metal Conduit and Electrical Metallic Tubing, Specifications for 5. WW-C-581…Federal Specification, Conduit, Metal, Rigid & Coupling, Elbow, and Nipple, Electrical Conduit, Zinc Coated 6. WW-C-540…Federal Specification, Conduit, Metal, Rigid (Electrical, Aluminum) 7. WW-C-571…Federal Specification, Conduit, Metal, Rigid, and Coupling, Elbow, and Nipple, Electrical Conduit Enameled 8. U.L. 6…Standards for Safety. Rigid Metal Conduit 9. U.L. 2142…Standards for Safety. Intermediate Metal Conduit 10. CEC Section 12-1000…Rigid and Flexible Conduit 11. CSA C22.2 No. 45…Safety Standards for Rigid Metal Conduit 12. CSA C22.2 No. 18…Safety Standards for Outlet Boxes, Conduit Boxes and Fittings 13. NEMA FB-1…Standards Publication. Fittings and Supports for Conduit and Cable Assemblies 14. A-A-50553 Federal Specification. Fittings for Conduit Metal Rigid (Thickwall & Thinwall [EMT] Type) Please Note The excerpts and other material herein, whether relating to the Canadian Standards Association, the Underwriters Laboratories, Inc. listing, to industry practice or otherwise, is not intended to provide all relevant information required for use and installation. Reference to original or primary source material and data is mandatory before any application or use is made of the product. 6 T&B Conduit Fittings Rigid Metal Conduit Fittings Suggested Specifications for Rigid Metal Conduit/PVC Coated Rigid Metal Conduit and Fittings meets 2009 CEC Rule 2-112 Cat. #CP8 KOPR-SHIELD* * TM of Jet-Lube, Inc. Cat. #AP8 ALUMA-SHIELD ® • Rigid ferrous metal conduit or PVC coated rigid conduit prior to coating shall be of the hot dipped galvanized type adequately protected against corrosion inside and outside including threads, and conforming to the following applicable specifications: -Rigid Ferrous Metal Conduit Federal Specification WW-C-581/ANSI C80.1/U.L. 6/CSA C22.2 No. 45 -PVC Coated Ferrous Metal Conduit Applicable listed under (i) and in addition conforming to NEMA Publication No. RNI-2005 (Type A) PVC coating on conduit and associated fittings shall have no sags, blisters, lumps or other surface defects and shall be free of holes. • Rigid nonferrous metal conduit shall conform to Federal Specification WW-C-540/ANSI C80.5/U.L. 6/CSA C22.2 No. 45. Series 1451 Knockout Plug Series 1470 Plug, Conduit/Fitting • All field cuts shall be square, reamed and deburred. Conduit threads shall be tapered for entire length with 3¼4” taper per ft. Conduit threads prior to assembly shall be clean and coated with grease metallic type conductive compounds such as series CP8 KOPR-SHIELD for ferrous conduit or series AP8 ALUMA-SHIELD for nonferrous (aluminum) conduit as manufactured by Thomas & Betts. • To prevent ingress of plaster, dirt, trash or moisture in raceways, boxes, fittings and equipment during course of construction, all open ends shall be closed with rugged thermoplastic plugs as manufactured by Thomas & Betts, series 1470 and 1451. Plugs shall be firmly secured in place to provide adequate seal and shall be functionally unaffected by moisture. Thermoplastic plugs shall be rated at 105°C/221°F and have a U.L. flammability rating of 94V-1. 7 T&B Conduit Fittings Rigid Metal Conduit Fittings Suggested Specifications for Rigid Metal Conduit/PVC Coated Rigid Metal Conduit and Fittings (continued) Series 1276 Conduit Strap Series 700 Adjustable Beam Clamp Series 690 Conduit Supports Series 1350 Conduit Spacer Series 140 Locknut Series 106 Bonding Locknut Series 5302 Sealing Gasket Series 370 Threaded Hub (Raintight) Series 485 PVC Coated Threaded Hubs (Raintight) Series 8120 Threadless Coupling (Concretetight) Series 8123 Threadless Fitting (Concretetight) Series 8125 Set Screw Fitting (Concretetight) • Conduit shall be securely fastened in place, at intervals as specified by the code, using suitable straps, hangers and other supporting assemblies as indicated on plans and as manufactured by Thomas & Betts, series 1276, 690 and 700. All strap hangers and supporting assemblies shall be of rugged construction capable of supporting weight with a reasonable factor of safety and shall be adequately protected against corrosion. Where applicable, it shall conform to Canadian Standards Association Standard C22.2 No. 18. • In wet locations or in locations where corrosive conditions are present, vertical and horizontal runs of conduit shall be firmly supported so that there is at least 1¼4” air space between the conduit and the wall or supporting surface. Spacers and supporting straps shall be of malleable iron construction, hot dipped galvanized conforming to Canadian Standards Association Standard C22.2 No. 18 such as Thomas & Betts series 1276 straps and series 1350 spacers. Nonferrous metal straps and spacers may be substituted as required. • Where threaded conduit terminates into a threadless opening, a locknut shall be provided both inside and outside the box or enclosure and the conduit end shall be fitted with an insulating bushing. In wet locations, a suitable gasket shall be provided between the outside locknut and the opening. Locknuts shall be rugged, of hardened steel or malleable iron construction, electro-zinc plated and capable of cutting through protective coating on box or enclosure to ensure positive bond such as Thomas & Betts series 140. Series 8124 Set Screw Fitting (Concretetight) 8 • Where raceway and associated fittings are used as part of an equipment grounding system, terminating fittings shall be equipped with bonding type locknuts such as Thomas & Betts series 106 bonding locknuts. Sealing gaskets shall be constructed of oil resistant/moisture resistant rubber and shall be suitably protected by and permanently bonded to a stainless steel retainer such as Thomas & Betts series 5302. • Where threaded rigid metal conduit is installed outdoor or indoors or in locations exposed to continuous or intermittent moisture, a sealing hub type terminating fitting shall be installed. Hubs shall be of malleable iron/steel construction, electro-zinc plated and equipped with a nylon insulated throat and oil resistant/moisture resistant sealing ring as manufactured by Thomas & Betts, series 370 or series H050-TB. Female taper hub threads shall be adequately relieved to prevent bottoming of conduit. Hubs constructed of copper-free aluminum may be substituted when used with rigid nonferrous (aluminum) metal conduit, Thomas & Betts series 370AL or H050A. For environmental conditions that are more than normally corrosive to exposed surfaces, hubs suitably protected with PVC coating such as Thomas & Betts series 485 shall be used. T&B Conduit Fittings Rigid Metal Conduit Fittings Suggested Specifications for Rigid Metal Conduit/PVC Coated Rigid Metal Conduit and Fittings (continued) Series 140 Locknut Series 3210 Knockout Bushing Series 222TB Insulating Bushing Series 1942 Insulated Nipple Series 674 Threaded Coupling Series TRIB50 Threadless Rigid Insulating Bushing Series 3870 Insulated Grounding & Bonding Bussing • Where concrete-tight requirements must be met, or in dry locations, rigid metal conduit or intermediate metal conduit fittings and couplings shall be of the concrete-tight type. Fittings shall be rugged, of ferrous metal construction, electro-zinc plated inside and outside, and furnished with a nylon bushing as manufactured by Thomas & Betts, series 8123 and 8120. Insulated set screw type fittings such as Thomas & Betts series 8125 and 8124 may be substituted unless otherwise indicated on drawings. Components critical to performance such as set screws, split rings, and locknuts shall be hardened or adequately designed to ensure positive bond between conduit and enclosure or conduit runs. All fittings of the system shall be capable of carrying ground fault currents per the following: 1/2” through 1-1/2” size…10,000 amps RMS (duration of fault current 3 cycles) 2” and above…20,000 amps RMS (duration of fault current 3 cycles) • All back-to-back nippling of boxes shall be done using locknuts and nylon bushed nipples as manufactured by Thomas & Betts, series 140 locknuts and series 1942 nipples. Nipples, or suitably designed bushings such as Thomas & Betts series 3210, shall also be used where conductors pass through either factory or field punched, cut or drilled holes in metallic members. 9 • Where neither length of threaded conduit can be rotated, couplings such as Thomas & Betts series 674 shall be installed in conduit runs. • Where threaded or threadless conduit terminates outside a box or an enclosure, or where conduit is stubbed up, it shall be equipped with an insulated metallic or nonmetallic bushing such as Thomas & Betts series 1222 or TRIB50. • Where code requires bonding and grounding of single or multiple rigid metal conduits or where positive bonding and grounding of conduit to the box, enclosure or auxiliary gutter is required, the end of the conduit shall be equipped with an insulated metallic grounding and bonding bushing such as Thomas & Betts series 3870. Insulated metallic grounding and bonding bushing shall be approved for the purpose. It shall be of malleable iron/steel construction adequately protected against corrosion, assembled with an insulator listed or certified for 150°C/302°F application and flammability rating of 94V-0 with insulator positively secured in place. Bonding to enclosure shall not be dependent on locknut bushing type contact but by a positive bonding means such as a hardened screw or equivalent. T&B Conduit Fittings Rigid Metal Conduit Fittings Specifications — Locknuts Application • To connect externally threaded conduit or fitting to a threadless opening in a box or enclosure. 140 Series 141AL Series • To effectively bond conduit or fitting to box or enclosure. Features • Hardened Steel/Malleable Iron/ Copper-free Aluminum construction. • Tightens without deformation. 106 Series • Locknuts specially designed to: (i) Provide extended reach for clamping on thin boxes and enclosures (ii) Cut through protective coating on box and enclosure thereby ensuring ground continuity (iii) Permit tightening from outside (iv) Prevent loosening under vibration • 106 Series provided with a hardened cone point screw. Standard Material 140 Series & 106 Series ¼8” thru 2” Steel (hardened) 2-1/2” thru 6” Malleable Iron All screws steel 3 141AL Series All copper-free aluminum (less than .4% copper) Standard Finish All Steel and Malleable Iron locknuts including bonding screws ..........................Electro-zinc Plated All Aluminum locknuts . . . . . . . .degreased For chromate coating use prefix 040 10 Range • 3/8” through 6” conduit (all threads straight pipe [NPS]) (140 Series) • 1/2” through 4” conduit (106 Series & 141AL Series) Conformance U.L. 514B CSA C22.2 No. 18.3 NEMA FB-1 ANSI C80.4 Federal Specification W-F-408 Federal Standard H-28 (Threads) “Case Hardened Locknuts” Case hardened locknuts make fittings faster and easier to install. Case hardened locknuts do not slip or turn thereby protecting the biting edge. Case hardened locknuts bite through the paint on the enclosure providing excellent continuity of ground (typical T&B/ Thomas & Betts fitting with case hardened locknuts successfully passed minimum fault current of 10,000 amps RMS). Case hardened locknuts when assembled in the intended manner will not vibrate loose thereby ensuring excellent ground continuity. T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings Locknuts (B) Thickness Steel or malleable iron (steel thru 2”) or Aluminum 624 Many of the T&B standard conduit and cable fittings are furnished with “case hardened locknuts”. This exclusive feature means the locknut tightens up against the box without deforming; the locknut bites into the box providing a positive ground; the fitting can be tightened from outside the box. Stl. or M.I. Cat. No. Alum. 139*† 140* 141** 142-TB** 143 144 145 146-TB 147 148 149 150 151 152 153 — — 141AL 142AL 143AL 144AL 145AL 146AL 147AL 148AL 149AL 150AL 151AL 152AL 153AL SST Size — — 141SST 142SST 143SST 144SST 145SST 146SST 147SST 148SST 149SST 150SST 151SST 152SST 153SST 1/4” 3/8” 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 3-1/2” 4” 4-1/2” 5” 6” Dimensions (in.) A B 27/32 15/16 1-7/64 1-3/8 1-11/16 2-5/32 2-1/2 3 3-9/16 4-3/16 4-13/16 5-5/16 5-15/16 6 -1/2 7-3/4 5/32 5/32 5/32 3/16 13/64 13/64 13/64 7/32 13/32 13/32 15/32 15/32 17/32 17/32 17/32 * Hex shape ** Case hardened locknuts Aluminum locknuts comply with federal standard of copper-free aluminum; less than .4% copper. For Dura-Plate™ finish, add prefix 040- to Cat. No. Consult Customer Service for details. † Not UL or CSA certified Bonding Locknuts Dimensions (in.) (B) Thickness Steel or malleable iron (steel thru 2”). Use anywhere an ordinary locknut is installed to ensure positive bonding of conduit to box and prevent loosening due to vibration. Also can be used for Service Entrance applications in conformance with Code. T&B rigid conduit and E.M.T. (thinwall) fittings comply with Federal Specification WF 408c. Cat. No. Size Screw Sizes A B 106 107 108 109 110-TB 111 112-TB 113-TB 114 115-TB 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 3-1/2” 4” 8-32x 7/16” 8-32x 7/16” 8-32x 7/16” 8-32x 7/16” 8-32x 7/16” 8-32x 7/16” 1/4-20x 5/8” 1/4-20x 5/8” 1/4-20x 5/8” 1/4-20x 5/8” 1-3/8 1-5/8 1-15/16 2-5/32 2-1/2 3 3-13/32 4-13/16 4-29/32 5-7/16 .125 .140 .170 .170 .170 .187 .375 .375 .438 .438 For Dura-Plate™ finish, add prefix 040- to Cat. No. Consult Customer Service for details. Steel finish: zinc plated Sealing Fittings Molded Santoprene Seal Color: Blue Provides positive seal against water and oil. For use with rigid and intermediate metal conduits, or fittings to provide watertight or raintight seal at all enclosures. NPS threads. Cat. No. Size A Dimensions (in.) B C 141SL 142SL 143SL 144SL 145SL 146SL 1/2 3/4 1 1-1/4 1-1/2 2 1.140 1.420 1.770 2.281 2.598 3.175 1/8 5/32 11/64 11/64 11/64 3/16 1/4 9/32 9/32 5/16 9/32 19/64 Steel finish: zinc plated 11 T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings Sealing Rings with Stainless Steel Retainer B A Sealing Ring-Santoprene Thermoplastic Rubber These sealing rings provide a liquid tight, dust tight, seal of fitting at enclosures. Dimensions (in.) B ± 1¼64 Cat. No. Conduit Size A 5302 5303 5304 5305 5306 5307 5308 5309 5311 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 4” 1-11/64 1-1/2 1-3/4 2-9/64 2-27/64 2-59/64 3-7/16 4-5/64 5-9/32 3/4 15/16 1-11/64 1-1/2 1-3/4 2-15/64 2-43/64 3-19/64 4-19/64 NEMA 3R, 4, 6 and 13 Bonding & Grounding Wedges Application To effectively bond terminating fitting or conduit to a box or enclosure. Standard Material/Finish 1/2” size ............Steel/Electro-zinc Plated 3/4” thru 6” size..........Bronze/Tin Plated Features • Sizes 3/4” thru 6” equipped with an additional bonding screw to install bonding jumper where required. Range 1/2” thru 6” conduit Series 3650 • Can be added to an existing installation without disconnecting conductors. Conformity U.L. 467 C.S.A. C22.2 No. 41 NFPA70-2008 (ANSI) Federal Specification A-A-50552 Series 3651 Bonding and Grounding Wedges Especially suited for grounding old work, but equally convenient for new, grounding wedges provide grounding without a jumper except in concentric knockouts. When a jumper is required, it fits under a set screw in the grounding wedge. Update existing installations to meet code requirements for bonding (CEC Section (10-806) without disconnecting wiring. Use on new wiring also. 1. Loosen bushing and position wedge. 2. Tighten bushing and bonding screw. Cat. No. Size 3650 3651 3652 3653 3654 3655 3656 3657 3658 3659 3661 3662 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 3-1/2” 4” 5” 6” 12 T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings Blackjack® — Conduit Grounding Bushings Mounting screw with nylon locking patch has a cone point to lock bushing securely in place. Integral grounding lug enhances ground continuity. Added ground wire range taking reduces inventory. Accepts copper or aluminum ground wires. Insulator surface features a rounded design to reduce drag and prevent abrasion during wire pulling. Insulating nylon surface is 150°C rated and covers top of bushing, including lug corners. Angle of lug screw improves accessibility when securing grounding wire. Cast “threads” opposite the mounting screw tighten the fit during installation. Innovative design makes installation quicker, easier. The Blackjack® Grounding Bushing never has to be threaded onto a conduit. It is simply placed in position on either a threaded or non-threaded rigid or IMC conduit, with the grounding lug in perfect position to accept the grounding wire. Even in tight installations, it’s as simple as one, two, three. Compare the installation with conventional bushings that must be threaded onto the conduit. In tight areas, you may have to remove the grounding lug, keep up with the loose parts, and then reattach the lug. Then you still have to twist and turn the bushing to get the lug in position to accept the grounding wire. The Blackjack bushing does away with these needless delays for good, making it the ideal grounding bushing and the only logical choice for small spaces, corners, and multiple conduit runs. And, because the grounding lug is an integral part of the bushing, it is designed not to fall off or get lost. Innovative design improves performance. The Blackjack® bushing provides superior ground continuity. The design of the Blackjack bushing has an integral, cast-on grounding lug for better ground continuity. This means that the Blackjack bushing stands up to intense loads. Secure grip forms lasting bond. The Blackjack bushing’s conepoint mounting screw bites securely into both threaded and non-threaded rigid conduits. And the Blackjack bushing’s nylon locking patch is designed to prevent the screw from loosening due to vibration. Reduce inventory. Because the Blackjack Grounding Bushing is designed for threaded and non-threaded conduits, and the ground lugs are designed to handle an extended range, the number of parts in inventory is reduced by up to two-thirds without losing any application coverage. Blackjack ® – Conduit Grounding Bushing Lug Screw: 14-4: Slotted 14-2/0: Slotted 6-4/0: Internal Hex Drive Standard Material/Finish Body: Malleable Iron or Aluminum Mounting Screw: (1/2"-2") Stainless Steel, (2 -1/2"-6") Brass Lug Screw: Stainless Steel Finish: Zinc Plated or Mechanical Galvanized 13 Range Conduit: 1/2 thru 6" threaded or threadless rigid/IMC Wire Range: #14 AWG to 4/0 AWG CU/AL Conformity U.L. 514B & U.L. 467 CSA C22.2 No. 18.3 & CSA C22.2 No. 41 T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings Blackjack® — Conduit Grounding Bushings Cat No. Zinc Plated Malleable Iron Cat No. Aluminum BG050-14-20 BG050-14-4 BG075-14-20 BG075-14-4 BG100-14-20 BG100-14-4 BG125-14-20 BG150-14-20 BG200-14-20 BG250-14-20 BG250-6-40 BG300-14-20 BG300-6-40 BG350-14-20 BG350-6-40 BG400-14-20 BG400-6-40 BG500-14-20 BG500-6-40 BG600-14-20 BG600-6-40 BGA050-14-20 BGA050-14-4 BGA075-14-20 BGA075-14-4 BGA100-14-20 BGA100-14-4 BGA125-14-20 BGA150-14-20 BGA200-14-20 BGA250-14-20 BGA250-6-40 BGA300-14-20 BGA300-6-40 BGA350-14-20 BGA350-6-40 BGA400-14-20 BGA400-6-40 BGA500-14-20 BGA500-6-40 BGA600-14-20 BGAT600-6-40 Conduit Size in. ØA Max. ØB Max. Dim. ØC Max. ØD Max. E Max. Wire Range 1/2 1/2 3/4 3/4 1 1 1-1/4 1-1/2 2 2-1/2 2-1/2 3 3 3-1/2 3-1/2 4 4 5 5 6 6 1.251 1.251 1.533 1.533 1.783 1.783 2.220 2.470 2.830 3.148 3.148 4.042 4.042 4.542 4.542 5.042 5.042 6.136 6.136 7.199 7.199 .569 .569 .772 .772 .993 .993 1.319 1.553 2.010 2.412 2.412 3.022 3.022 3.491 3.491 3.975 3.975 4.991 4.991 6.009 6.009 1.181 1.027 1.221 1.030 1.181 1.027 1.181 1.181 1.181 1.181 1.524 1.181 1.524 1.181 1.524 1.181 1.524 1.181 1.524 1.181 1.524 2.134 1.940 2.414 2.168 2.581 2.368 2.987 3.236 3.766 4.341 4.526 4.966 5.139 5.467 5.639 5.966 6.139 7.045 7.207 8.087 8.409 .696 .696 .696 .696 .696 .696 .759 .696 .696 .978 .978 .978 .978 .978 .978 .978 .978 .978 .978 .978 .978 14-2/0 14-4 14-2/0 14-4 14-2/0 14-4 14-2/0 14-2/0 14-2/0 14-2/0 6-4/0 14-2/0 6-4/0 14-2/0 6-4/0 14-2/0 6-4/0 14-2/0 6-4/0 14-2/0 6-4/0 Suggested Specifications Insulated grounding and bonding bushing (Series BG050-BG600) Where code requires bonding and grounding of single or multiple metal conduits, or positive bonding and grounding of metal conduit to the box, enclosure or auxiliary gutter, the end of the conduit shall be equipped with an insulated metallic grounding and bonding bushing series BG050-14-20 as manufactured by Thomas & Betts. Grounding and bonding bushings used shall be approved for the purpose and (i) Shall be of malleable iron/steel/aluminum construction adequately protected against corrosion. (ii) Bushing insulator shall be listed or certified for 150°C/302°F application with a flammability rating of 94V-O. Insulator must be positively locked in place. * Mechanical galvanization is available in the 3870 Series; add suffix MG to Cat. No. Nylon Insulator (150oC) Mounting Screw Lug Screw 14-4: Slotted 14-2/0: Slotted 6-4/0: Internal hex drive t t t t C ØA E t t t t ØB Throat I.D. D t t For Threaded & Threadless Rigid & IMC Conduit. 14 T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings Threaded Insulated Grounding Bushing Application • For quick installation of bonding jumper to multiple metal conduits (Rigid and IMC). • Designed to bush conductors and prevent insulation damage. Standard Material / Finish Body: Electro-zinc plated Lay-in lug: Aluminum/tin plated Insulator: Thermoplastic 150°C/302°F Application with 94V-0 flammability. Features • Ease of installation, lay in lug design. • Cast malleable iron body designed to lock insulator in place within body reducing common assembly problem resulting in dislodging of insulator. • Insulator rated for 150°C/302°F application. Wire Clamping Screw Insulator Set-Screw (one) Threaded Insulated Grounding Bushing Lay-In* Lug Bushing Casting Cat. No. Conduit Size Bushing Dia. Throat Dia. Lug Length Swing Radius Bushing Height Wire Range AWG CU/AL 3870-TB 3861 3871-TB 3862 3872 3882 3873 3883 3874 3884 3875 3889 3876 3886 3993 3877 3887 3994 3878 3863 3995 3879 3864 3996 3880 3865 3998 3881 3866 3999 1/2 1/2 3/4 3/4 1 1 1-1/4 1-1/4 1-1/2 1-1/2 2 2 2-1/2 2-1/2 2-1/2 3 3 3 3-1/2 3-1/2 3-1/2 4 4 4 5 5 5 6 6 6 1.125 1.125 1.420 1.420 1.770 1.770 2.190 2.190 2.468 2.468 3.031 3.031 3.516 3.516 3.516 4.234 4.234 4.234 4.781 4.781 4.781 5.328 5.328 5.328 6.328 6.328 6.328 7.406 7.406 7.406 .560 .560 .742 .742 .944 .944 1.242 1.242 1.449 1.449 1.860 1.860 2.222 2.222 2.222 2.761 2.761 2.761 3.193 3.193 3.193 3.623 3.623 3.623 4.542 4.542 4.542 5.458 5.458 5.458 1.310 1.675 1.310 1.675 1.310 1.675 1.310 1.675 1.310 1.675 1.310 1.675 1.310 1.675 2.230 1.310 1.675 2.230 1.310 1.675 2.230 1.310 1.675 2.230 1.310 1.675 2.230 1.310 1.675 2.230 1.212 1.402 1.360 1.550 1.535 1.725 1.745 1.935 1.884 2.074 2.165 2.355 2.408 2.598 2.928 2.767 2.957 3.287 3.040 3.230 3.560 3.314 3.504 3.834 3.814 4.000 4.334 4.353 4.543 4.875 .657 .657 .660 .660 .735 .735 .735 .735 .770 .770 .770 .770 .940 .940 .940 .975 .975 .975 .975 .975 .975 .980 .980 .980 .985 .985 .985 1.200 1.200 1.200 14-4 8-2/0 14-4 8-2/0 14-4 8-2/0 14-4 8-2/0 14-4 8-2/0 14-4 8-2/0 14-4 8-2/0 6-4/0 14-4 8-2/0 6-4/0 14-4 8-2/0 6-4/0 14-4 8-2/0 6-4/0 14-4 8-2/0 6-4/0 14-4 8-2/0 6-4/0 Temperature rating 150°C. Meets Coast Guard Regulation CG293 For Dura-Plate™ finish, add prefix 040- to Cat. No. Consult Customer Service for details. *Contact customer service for copper lay in lug 15 T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings Insulated Throat Fittings Dimensions (in.) Nylon insulated metallic bushings Steel or malleable iron (Steel thru 1-1/2”). The Canadian Electric Code 10-906 (2) calls for protection of ungrounded conductors by means of smoothly rounded insulating surfaces at the entrance to raceways, pull boxes, junction boxes, etc. T&B insulated throat fittings, recognizable by the distinctive trademarked blue insulating liner in the throat, meet and surpass this Code requirement. In addition, T&B insulated fittings also reduce wire pulling effort by as much as 50%. Temperature rating 105°C. Cat. No. Size A B 1222 1223 1224 1225 1226 1227 1228 1229 1230 1231 1232† 586 587 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 3-1/2” 4” 4-1/2” 5” 6” 1-1/32 1-9/32 1-19/32 1-15/16 2-3/16 2-11/16 3-3/16 3-27/32 4-7/16 4-7/8 5-7/16 5-31/32 7-3/16 29/64 31/64 19/32 21/32 23/32 7/8 31/32 15/16 1-1/16 1-3/32 1-15/64 1-9/32 1-11/32 Not CSA Certified Catalogue series 1222 thru 1232, 586 and 587 are available in aluminum. Add suffix AL to Cat. No. The aluminum series are not CSA certified. † Metallic Bushings Cat. No. Aluminum, steel or malleable iron (steel thru 1-1/2”). Smoothly rounded shoulder covers end of conduit; broad flange covers knockout hole. High ribs make tightening easy with fingers or with wrench. 1/2”-1-1/2” sizes, formed in steel, have extra smooth shoulders. Locknut-type base gives improved bonding and resists loosening under conditions of vibration. Stl. or M.I. Alum. Size 122 123 124 125-TB 126 127 128 129 130-TB 131-TB 132-TB 133-TB 134-TB 122AL 123AL* 124AL 125AL 126AL 127AL 128AL 129AL 130AL 131AL — 133AL 134AL 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 3-1/2” 4” 4-1/2” 5” 6” Dimension (in.) A 1-1/32 1-9/32 1-19/32 1-15/16 2-3/16 2-11/16 3-3/16 3-27/32 4-7/16 4-7/8 5-7/16 6-1/16 7-3/16 B 13/32 13/32 1/2 9/16 9/16 19/32 13/16 13/16 15/16 1 1-5/64 1-1/16 1-1/16 * Not U.L. Listed or CSA Certified For Dura-Plate™ finish, add prefix 040- to Cat. No. Consult Customer Service for details. 16 T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings Plastic Insulating Bushings Dimensions (in.) A Cat. No. B All Plastic Insulating Bushings Impact-resistant plastic insulation. These bushings have ribs for gripping when installing. Perfect threads for easy thread on. U.L. Listed 105°C. NPT threaded. 222-TB 223-TB 224 225-TB 226 227 228-TB 229-TB 230-TB 231 232 233 234 Size A B 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 3-1/2” 4” 4-1/2” 5” 6” 1-1/16 1-9/32 1-37/64 2-1/32 2-15/64 2-25/32 3-13/32 4-3/32 4-5/8 5-3/16 5-5/8 6-3/8 7-7/16 3/8 13/32 9/16 9/16 9/16 5/8 3/4 3/4 7/8 7/8 7/8 1 1 Flame retardant. U.L. Rated 94V-1. 17 T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings Insulating Bushing (For Threadless Rigid Conduit and Intermediate Metal Conduit) TRIB50 Series Application • When assembled to the end of a threadless conduit, provides a well rounded insulating surface over which conductors may be pulled or on which conductors may bear while in service. Standard Material High impact thermoplastic listed for 105°C (221°F) application. Flammability Classification 94V-1. Features • Designed to be popped onto, and bush, conduit end. Range 1/2” through 4” conduit Standard Finish As molded. • Fast easy installation without screws. 1. Cut conduit end squarely. Remove sharp edges and burrs on inside and outside diameters by reaming or filing. 2. Slip the pop-on bushing over the end of the conduit. 3. Using the flat surface of any standard utility tool such as an electricians pliers (or a hammer with a block of wood, for the larger sizes), strike the bushing on its top surface using a series of light blows until the end of the conduit rests against the bushing throat and conduit stop. • High impact thermoplastic construction. Conformity U.L. 514B ANSI C80.4 NFPA 70-2008 (ANSI) Insulated Metallic Bushing Cat. No. TRIB-50 TRIB-75 TRIB-100 TRIB-125 TRIB-150 TRIB-200 TRIB-250 TRIB-300 TRIB-350 TRIB-400 Size A Dimensions (in.) B C 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 3-1/2” 4” 19/32 25/32 1 1-5/16 1-17/32 1-31/32 2-23/64 2-59/64 3-3/8 3-27/32 1-9/32 1-25/64 1-1/2 1-5/8 1-21/32 1-13/16 2 2-7/32 2-5/16 2-13/32 1-1/16 1-1/4 1-9/16 1-59/64 2-11/64 2-11/16 3-1/4 3-29/32 4-29/64 5 I.M.C. sizes 1/2” thru 4” U.L. Rated flame retardant 94V-1. A B C 18 T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings Knockout Bushings Range • .875” through 2.469” nominal diameter knockout opening (1/2” through 2” trade size knockouts). Application • To bush knockout openings in metal boxes or enclosures. Features • One piece construction designed to snap in place. • High impact strength self-extinguishing, non-dripping (per U.L. 94) thermoplastic construction. 3210 Series Standard Material Thermoplastic rated for 105°C (221°F) application. • Wall thickness of box or enclosure .095” max. up to 1” trade size. .140” max. 1-1/4” through 2” trade size. Conformity U.L. 514B CSA C22.2 No. 18.3 NFPA 70-2008 (ANSI) Standard Finish As molded. Knockout Bushing One-piece knockout bushing quickly snaps into outlet box, switch box, or other enclosure left vacant by wiring modifications or maintenance changes. Provides smooth, rounded insulation surface for easy wire pulling. Easily installed by hand, they are available to fit 1/2” through 2” knockouts. U.L. Listed 105°C. High impact thermoplastic. Cat. No. Trade Size For use in KO* +.032 / -.016 A 3210 3211 3212 3213 3214 3215 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” .875 1.109 1.375 1.734 1.984 2.469 1.000 1.215 1.500 1.865 2.240 2.740 B Wall Thickness of Elec. Box C D .725 .940 1.200 1.550 1.760 2.245 .095 MAX .095 MAX .095 MAX .140 MAx .140 MAX .140 MAx .360 .360 .360 .400 .530 .530 .180 .180 .180 .210 .310 .310 * Per U.L. and NEMA standards. Material: Thermoplastic Flammability classification of 94V-1 Per UL 94 Service temperature: -40°C to 105°C. ® INSULINER Sleeves Dimension (in.) Cat. No. B A Slip over wires—insert into bushing—snaps into place High dielectric nylon, 105°C. An insuliner sleeve snapped into a regular bushing makes a CSA Listed insulated bushing. For standard rigid conduit, E.M.T. (thinwall conduit) or any standard bushed outlet. Especially suitable for use with flexible metallic conduit. Converts ordinary bushing to code approved insulated bushing without disturbing wiring. 422 423 424 425 426-TB 427-TB 428-TB 429 430-TB 431 433 434 Oxygen index >28° 19 Size A B 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 3-1/2” 4” 5” 6” 5/8 11/16 7/8 1 1 1-1/8 1-1/4 1-1/2 1-25/32 2-1/32 2-1/2 2-1/2 .022 .025 .040 .040 .050 .050 .035 .035 .035 .035 .035 .035 T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings Pennies—Steel Cat. No. Size 815-TB 816 817 818 819 820 821 822 824 823 U.L. not applicable A penny under a bushing will seal the end of the conduit during construction. Made to fit any bushing. Completely salvageable. 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 3-1/2” 4” Knockout Plugs Application • To bush knockout openings in metal boxes or enclosures. Features • One piece construction designed to snap in place. • High impact strength self extinguishing nondripping (per U.L. 94) thermoplastic construction. Standard Material Thermoplastic rated for 105°C (221°F) application. Range • .875” through 2.469” nominal diameter knockout opening (1¼2” through 2” trade size knockouts). • Wall thickness of box or enclosure .095” max. up to 1” trade size. .140” max. 1-1/4” through 2” trade size. Conformity U.L. 514B CSA C22.2 No. 18.3 NFPA 70-2008 (ANSI) Standard Finish As molded. Knockout Plugs Dimensions (in.) B A 105°C rated by U.L. Made from flame retardant, non-dripping thermoplastic. Cat. No. Size A B 1451 1452 1453 1454 1455 1456 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 1.060 1.300 1.590 1.860 2.240 2.740 .400 .400 .400 .450 .570 .570 Wall thickness of electrical box .095 max. Meets Coast Guard Regulation CB293. 20 T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings Plug, Conduit, Connectors (Push-Penny® Plugs) Application • To plug open end of conduit or fitting in order to prevent ingress of trash, dirt or moisture during construction and remodeling. Standard Finish As molded. Features • Wide range of application; can be used with rigid metal conduit, intermediate metal conduit, electrical metallic tubing, all connnectors and all bushings. • Designed to stand up to normal handling and is functionally unaffected by moisture. CSA C22.2 No. 18 ANSI C80.4 NFPA 70-2008 (ANSI) NEMA FB-1 Conformity CEC Rule: 12-3024 “Unused openings in boxes, cabinets and fittings shall be effectively closed by plugs or plates affording protection substantially equivalent to that of the wall of the box, cabinet or fittings.” Standard Material Polyethylene ® Push-Penny Plugs Cat. No. Size 1470-TB 1471 1472 1473 1474 1475 1476* 1477* 1478* 1479* *Not CSA Certified. CSA File No. 2884 UL not applicable. 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 3-1/2” 4” ® Bushings and Push-Penny Plugs A Cat. No. Size A 1460 1461 1462 1463 1464 1465* 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 1-1/32” 1-9/32” 1-19/32” 1-15/16” 2-3/16” 2-21/32” * Maleable Iron Available in Aluminum Add suffix AL to Cat. No. 21 Assembly consist of Bushing Push-penny 122 123 124 125 126 127 1470-TB 1471 1472 1473 1474 1475 T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings ® CHASE Nipple NPS Threads Application • To effectively bush factory or field-punched, cut, or drilled holes in metal boxes or enclosures. 842AL Series All Copper-free Aluminum (less than .4% copper) Standard Finish 1942 Series Electro-zinc Plated & Chromate Coated 842AL Series Degreased • To couple boxes back-to-back. 1942 Series 842AL Series (Non Insulated) Features • Rugged construction. Range 1942 & 842AL Series 1 ¼2” through 6” All hub threads straight pipe (NPS). •Insulator curled over to: Bush conductors entering/leaving at any angle. Reduce wire pull effort. Protect threads against damage in handling. Conformity U.L. 514B CSA C22.2 No. 18.3 Federal Specification W-F-408 ANSI C80.4 NFPA 70-2008 (ANSI) NEMA FB-1 Federal Standard H-28 (Threads) Standard Material 1942 Series Body 1/2”-Steel 3/8”, 3/4” through 6”-Malleable Iron Insulator Nylon ® CHASE Nipples Cat. No. Stl. or M.I. Steel, malleable iron or aluminum. 841TB 842TB 843TB 844 845 846 847 848 849 850 851 853 854 Dimensions (in.) Alum. Size A B — 842ALTB† 843ALTB 844AL† 845AL† 846AL 847AL 848AL 849AL 850AL 851AL 853AL 854AL 3/8” 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 3-1/2” 4” 5” 6” 13/16 15/16 1-3/16 1-7/16 1-3/4 2-1/16 2-1/2 3-1/16 3-13/16 4-3/8 4-3/4 5-7/8 6-15/16 7/16 11/32 11/32 21/32 3/4 13/16 31/32 1-1/16 1-3/16 1-5/16 1-5/16 1-5/16 1-3/8 Not U.L. Listed For Dura-Plate™ finish, add prefix 040- to Cat. No. Consult Customer Service for details. † 22 T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings CHASE® Nipples—Nylon Insulated Steel or malleable iron Cat. No. Size in. A Dimensions (in.) B C 1942 1943 1944 1945 1946 1947 1948 1949 1950 1951 1953 1954 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 5 6 15/16 1-3/16 1-7/16 1-3/4 2-1/16 2-9/16 3-1/16 3-13/16 4-3/8 4-5/8 5-29/32 6-13/16 1/2 17/32 21/32 25/32 13/16 31/32 1-1/16 1-3/16 1-5/16 1-5/16 1-5/16 1-3/8 19/32 23/32 7/8 1-1/32 1-3/32 1-11/32 1-7/16 1-19/32 1-25/32 1-13/16 1-13/16 1-7/8 23 T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings Threaded Hubs (Bullet® Hubs) (A) Predetermined Compression (B) (C) (E) (D) 370 Series 370AL Series (For Threaded Rigid Metal Conduit/IMC/PVC Coated Rigid Metal Conduit) Application • To connect threaded metal conduit (ferrous rigid/nonferrous rigid/PVC coated/or intermediate metal) to a threadless opening in a box or enclosure in outdoor or indoor location exposed to continuous or intermittent moisture. • Suitable for hazardous location use per following: (i) Class II, Division 1 Groups E, F, G, CEC Rule 18-202 Class II, Division 2 Groups E, F, G, CEC Rule 18-252 Class III, Division 1 Rule 18-302 Class III, Division 2 Rule 18-352 • To positively bond conduit to box or enclosure. • PVC coated 485 Series (i) Protects fitting from extremely corrosive surroundings without affecting integrity of electrical grounding path (F). (ii) Provided with overlapping sleeve for additional seal (G). Features • Rugged steel/malleable iron/copperfree aluminum construction. (G) (A) • Tapered internal threads for watertight/dust tight union (A). (F) (B) (G) (C) (D) (E) 485 Series • Threads relieved to prevent bottoming of conduit ensuring sound assembly (B). • Recessed sealing ring at box end. Captive sealing ring (C). • Hardened steel/malleable iron/ copper-free aluminum locknuts designed to provide high quality ground continuity; extended reach of locknut permits clamping on thin boxes and enclosures (D). • Insulated throat protects conductors, prevents abrasion and thinning of conductor insulation, reduces wire pull effort (E). 24 Canadian Electric Code Rule 10-602 states that, “Where dissimilar metals cannot be avoided at bonding connections as indicated in Rule 2-112 (2). Connections shall be made using methods or material that will minimize deterioration from galvanic action”. Joint Industrial Council (JIC) Electrical Standards also forbid dissimilar metals in contact for the same reason and require that the fittings for metal conduit be of malleable iron or ductile iron and have impact strength comparable to that of the conduit. “Copper-free Aluminum” • Copper-free aluminum castings for fittings have a maximum of 0.4% copper. The most detrimental effect of higher percentage of copper on aluminum base alloy is its decrease in corrosion resistance. T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings Threaded Hubs (Bullet® Hubs)—continued (For Threaded Rigid Metal Conduit/IMC/PVC Coated Rigid Metal Conduit) Standard Material 370-485 Series Body 1/2” thru 1” Steel 1-1/4” thru 6” Malleable Iron 1/2” thru 2” Steel (hardened) 2-1/2” thru 6” Malleable Iron Locknut Screws ‘O’ Ring Insulator Coating 370AL All Copper-Free Aluminum 1/2” thru 2” Steel (hardened) 2-1/2” thru 4” Copper-free Aluminum Steel (hardened) Buna N Nylon PVC Standard Finish Hub Locknuts Screws 370 Series Electro-zinc Plated 370AL Series As Cast Chromate Coated. All Ferrous locknuts Electro-Zinc Plated and Chromate Coated. All Electro-Zinc Plated & Chromate Coated. Range 370 Series 1/2” thru 6” Conduit 370AL & 485 Series 1/2” thru 4” Conduit All hub threads—straight pipe All female threads—taper pipe (NPT) Conformity U.L. 514B CSA 22.2 No. 18.3 ANSI C80.4 NFPA 70-2008 (ANSI) NEMA FB-1 JIC EGP1; JIC EMP 1 Federal Specification W-F-408 Federal Standard H-28 (Threads) 25 485 Series PVC—Outside. Electro-zinc Plated Chromate Coated Inside. T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings Steel/Malleable Iron and Aluminum Hub Fittings† Cat. No. Nylon insulated. Aluminum, steel, or malleable iron (steel through 1”). With Neoprene “O” Ring provides a watertight threaded hub on enclosures. U.L. Listed 105°C. A Dimensions (in.) B 1-3/8 1-5/8 2-3/32 2-9/16 3-3/32 3-5/8 4-1/8 5 5-9/16 6-9/16 8 9-3/16 1-5/16 1-3/8 1-23/32 2 2 1-31/32 2-21/32 2-31/32 3-1/8 3-1/8 4 4 Size Stl. or M.I. Alum.** 370 371 372 373 374 375 376 377 378 379-TB 381-TB 382-TB 370AL 371AL 372AL 373AL 374AL 375AL — — — — — — 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 5 6 C Wall Thk. (max.)in. 3/4 7/8 1-7/32 1-11/32 1-11/32 1-11/32 1-15/16 2 2-1/8 2-1/8 2-3/16 2-3/16 5/16 5/16 5/16 5/16 5/16 5/16 5/16 1/2 1/2 1/2 1/2 1/2 ** Aluminum not available with insulated throat. † U.L. Listed raintight and CSA Certified watertight and dust tight. For Dura-Plate™ finish, add prefix 040- to Cat. No. Consult Customer Service for details. Bullet Hub Fittings with Bonding Locknut — Nylon Insulated ® Cat. No. 401 402 403-TB 404-TB 405-TB 407 408 409 410-TB Size (in.) 1/2 3/4 1 1-1/4 1-1/2 2-1/2 3 3-1/2 4 CSA certified watertight and dust tight. 26 Description Available in steel or malleable iron (steel through 1 inch.). Used with a neoprene “O” ring to provide Supplied with 106 series bonding nut. Temperature rating: 105° C. T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings PVC Coated Hub for Rigid Conduit Cat. No. Steel or malleable iron (steel thru 1-1/4”). B LOCKNUT PLASTIC COATING NFS THREAD Conduit Size A Dimensions (in.) B C 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 3-1/2” 4” 1-21/64 1-19/32 1-27/32 2-15/32 2-29/32 3-3/8 3-27/32 4-21/32 5-9/64 5-3/4 2-1/8 2-3/8 2-3/4 3-3/8 3-5/8 3-3/4 4 4-5/8 4-13/16 4-9/16 1-7/8 2-1/8 2-3/8 3-1/8 3-1/2 4 4-1/2 5-3/8 5-7/8 6-7/16 485 486 487 488 489 490 491 492 493 494 *485 Series are CSA Certified Watertight and Dustight for Ordinary Locations. C A INSULATOR SEALING RING Spacing Chart for Bullet ® Hubs Center to Center Spacing Conduit Sizes Min. Space from Center of KO Bullet® Hub to Diameters Wall of Box (min.) 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 1/2 1-7/16 1-5/8 1-3/4 2-1/8 2-3/8 2-5/8 2-7/8 3-5/16 3-1/2 3-7/8 3/4 7/8 3/4 — 1-3/4 1-7/8 2-1/4 2-1/2 2-3/4 3 3-1/2 3-3/4 4-1/8 7/8 1-1/8 2-3/8 2-5/8 1 — — 2 1-1/4 — — — 1-1/2 — — — — 2 — — — — 2-7/8 3-1/8 3-5/8 3-7/8 4-1/4 1-1/8 1-3/8 3-1/4 3-1/2 4 4-1/4 4-1/2 1-3/8 1-3/4 3-1/8 3-1/2 3-3/4 4-1/8 4-3/8 4-3/4 1-5/8 2 — 3-3/4 4 4-1/2 4-3/4 5 1-7/8 2-1/2 2-11/16 2-15/16 2-1/2 — — — — — — 4-1/4 4-3/4 5 5-3/8 2-1/8 3 3 — — — — — — — 5-1/8 5-3/8 5-3/4 2-5/8 3-5/8 3-1/2 — — — — — — — — 5-5/8 6 2-7/8 4-1/8 4 — — — — — — — — — 6-1/4 3-1/4 4-5/8 T&B Hub Centerline Spacing Chart Conduit Trade Size inc. 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 3-1/2” 4” 5” 6” 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 3-1/2” 4” 5” 6” 1-9/16 1-43/64 1-27/32 2-1/32 2-7/32 2-15/32 2-23/32 3-1/32 3-11/32 3-19/32 4-9/32 4-11/16 1-25/32 1-61/64 2-9/64 2-21/64 2-37/64 2-53/64 3-9/64 3-21/64 3} 3-25/64 4-51/64 2-1/8 2-5/16 2-1/2 2-3/4 3 3-5/16 3-5/8 3-7/8 4-9/16 4-31/32 2-1/2 2-11/16 2-15/16 3-3/16 3-1/2 3-13/16 4-1/16 4-3/4 5-5/32 2-7/8 3-1/8 3-3/8 3-11/16 4 4-1/4 4-15/16 5-11/32 3-3/8 3-5/8 3-15/16 4-1/4 4-1/2 5-3/16 5-19/32 3-7/8 4-3/16 4-1/2 4-3/4 5-7/16 5-27/32 4-1/2 4-13/16 5-1/16 5-3/4 6-5/32 5-1/8 5-3/8 6-1/16 6-15/32 5-5/8 6-5/16 6-23/32 7 7-13/32 7-13/16 1-1/8 1-5/16 1-1/2 1-3/4 2 2-5/16 2-5/8 2-7/8 2-9/16 3-31/32 Nearest obstruction to center of hub. 27/32 61/64 27 T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings THE T&B Hub Never before has a single hub fit like this one. Designed for unequalled performance. The innovative engineering of the T&B Hub will, quite simply, raise your performance expectations for threaded hubs. The revolution in hub design is here, and the fate of our competition is sealed. Figure 1 1. Sealing ring and groove with innovative profile outperforms standard 'O' ring design. Sealing ring is captive before installation and resists buckling or slipping during installation. The seal groove is designed for optimum compression of the sealing ring. The sealing ring is designed to provide a complete 360° seal, even when the conduit is not perpendicular with the enclosure. (See Figure 1) Figure 2 Figure 3 4. Hexagonal / splined body design for fast, easy installation with wrench or hammer and screwdriver. 2. Locknut design with peripheral slots and a hexagonal/angled spline spaced every 30° enables easy application of torque with wrench or hammer and screwdriver. (See Figures 2 & 3) 5. Precision machined tapered threads designed to create watertight union. 3. Sharper and deeper teeth on locknut and body designed for a more penetrating bite for improved bonding to the enclosure. 6. Insulated throat molded from 105°C rated thermoplastic with a flammability rating of 94 V-O. T&B Hub Throat Dia. E B C D A Cat. No. Trade Size (in.) Dia. A B H050-TB H075-TB H100-TB H125-TB H150-TB H200-TB H250-TB H300-TB H350-TB H400-TB H500-TB H600-TB 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 5 6 1-7/16 1-21/32 2 2-3/8 2-3/4 3-1/4 3-3/4 4-3/8 5 5-1/2 6-7/8 7-11/16 1-9/16 1-19/32 1-13/16 1-7/8 1-7/8 1-15/16 2-9/16 2-21/32 2-23/32 2-23/32 3-1/32 3-5/32 C Max. Panel Thickness D Throat Dia. E 7/8 29/32 1-1/16 1-1/16 1-1/16 1-5/32 1-9/16 1-19/32 1-5/8 1-5/8 1-15/16 2 3/16 3/16 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 19/32 25/32 1 1-5/16 1-17/32 1-31/32 2-13/32 2-31/32 3-13/32 3-7/8 4-15/16 6 Material – Hub and Locknut: zinc or copper free aluminum Insulating Throat: thermoplastic temp. rating – 105°C, Flammability Rating: – 94V-0 Sealing Ring Nitrile (BUNA “N”) For Aluminum Hubs add suffix A (i.e. H050A). For Chrome Plated Hubs add suffix CP (i.e. H050CP). Meets NEMA sealing requirements for NEMA 3R, 4 & 13 enclosures. U.L. Listed and CSA Certified. CSA Certified use in hazardous locations Class I, Division 2, Class II, Divisions 1 and 2, Groups E, F and G, Class III, Division 1, 2 and Type 4. Chrome Plated Hubs (suffix-“CP”) are rated NEMA 4X. 28 T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings T&B Grounding Hub A Cat. No. Trade Size Dia. H050GR-C H075GR-C H100GR-C H125GR-C H150GR-C H200GR-C H250GR-C H300GR-C H350GR-C H400GR-C H500GR-C H600GR-C 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 5 6 17/16 12-1/32 2 2-3/8 2-3/4 3-1/4 3-3/4 4-3/8 5 5-1/2 6-7/8 7-11/16 B Dimensions (in.) C 19/16 1-19/32 1-13/16 1-7/8 1-7/8 1-15/16 2-9/16 2-21/32 2-23/32 2-23/32 3-1/32 3-5/32 7/8 29/32 1-1/16 1-1/16 1-1/16 1-15/32 1-9/16 1-19/32 1-5/8 1-5/8 1-15/16 2 D Max. Panel Thickness E Throat Dia. 3/16 3/16 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 1/4 5/16 19/32 25/32 1 1-5/16 1-17/32 1-31/32 2-13/32 2-31/32 3-13/32 3-7/8 4-15/16 6 Throat Dia. E B C A Material—Hub and Locknut: zinc or copper-free aluminum. Insulating Throat: thermoplastic temp. rating—105°C; flammability rating:—94V-0. Sealing Ring: Nitrile (BUNA “N”) For Aluminum Grounding Hubs add suffix A (i.e. H050GRA-C). For Chrome Plated Hubs add suffix CP (i.e. H050GRCP). For 316 Stainless Steel Hubs add suffix SST (i.e. H050GRSST). For PVC coating add suffix PVC (i.e. H050GRPVC-C). Meets NEMA sealing requirements for NEMA 3R, 4 & 13 enclosures. U.L. Listed and CSA Certified. CSA approved for use in hazardous locations: Class I, Division 2, Class II, Divisions 1 & 2, Groups E, F & G, Class III, Division 1, 2 and Type 4. T&B Grounding and Bonding Locknut Cat. No. Trade Size A Dia. B Height Ground Screw Max. Conductor Size L050GR-C L075GR-C L100GR-C L125GR-C L150GR-C L200GR-C L250GR-C L300GR-C L350GR-C L400GR-C L500GR-C L600GR-C 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 5 6 1-1/2 1-11/16 2 2-3/8 2-3/4 3-1/4 3-3/4 4-3/8 5 5-1/2 6-5/8 7-11/16 13/32 13/32 13/32 15/32 15/32 15/32 11/16 23/32 23/32 23/32 23/32 23/32 #10-32 x 1/4” #10-32 x 1/4” #10-32 x 1/4” 1¼4-20 x 1/4” 1¼4-20 x 5/16” 1¼4-20 x 5/16” 1¼4-20 x 5/16” 1¼4-20 x 5/16” 1¼4-20 x 5/16” 1¼4-20 x 5/16” 3¼8-16 x 3/8” 3¼8-16 x 3/8” #10 #10 #10 #10 #8 #8 #6 #6 #6 #4 #2 #1 Material—Locknut: zinc or copper-free aluminum For Aluminum Locknuts add suffix A. (i.e. L050GRA-C) For Chrome Plated Locknuts add suffix CP. (i.e. L050GR-CP) For 316 Stainless Steel Locknuts add suffix SST (i.e. L050GRSST). Grounding Locknut for Hubs 29 T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings T&B Bulkhead Fittings Bulkhead Fitting Across Flats Diameter Thread Nipple Nut Not Included Cat. No. Trade Size H050BHD H075BHD H100BHD H125BHD H150BHD H200BHD H250BHD H300BHD H350BHD H400BHD H500BHD H600BHD 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 3-1/2 4” 5” 6” Thru Bulkhead Fitting Trade Cat. No. Size H050TBF H075TBF H100TBF H125TBF H150TBF H200TBF Height 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” Thru Bulkhead Hub Trade Cat. No. Size H050TBH H075TBH H100TBH H125TBH H150TBH H200TBH Trade Size 1/2” 3/4” 1” 1/4” 1-1/2” 2” 2-1/2” 3” 3-1/2” 4” 5” 6” 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” Thread Height Diameter Across Flats A B 1/2”-14 3/4”-14 1”-11-1/2 1-1/4”-11-1/2 1-1/2”-11-1/2 2”-1-1/2 2-1/2”-8 3”-8 3-1/2”-8 4”-8 5”-8 6”-8 1-13/32 1-15/32 1-11/16 1-25/32 1-13/16 1-27/32 29/32 2-9/16 2-9/16 2-9/16 2-23/32 3 1-7/16 1-11/16 2 2-3/8 2-3/4 3-1/4 3-3/4 4-3/8 5 5-1/2 6-5/8 7-11/16 1 1-1/4 1-17/32 1-27/32 1-1/8 2-5/8 3-1/8 3-25/32 4-9/32 4-27/32 5-29/32 7-1/32 3/4 25/32 29/32 29/32 29/32 15/16 17/32 15/16 1-3/8 1-3/8 1-15/32 1-1/2 1/2 17/32 19/32 21/32 21/32 21/32 7/8 29/32 7/8 7/8 7/8 31/32 Material—Hub, Body and Locknut: zinc or copper-free aluminum Insulating Throat: thermoplastic temp. rating—105°C; Flammability rating:—94V-0 Sealing Ring: Nitrile (BUNA “N”) For Aluminum Bulkhead add suffix A. For Chrome Plated Bulkhead add suffix CP. 30 T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings Offset Reducers C Cat. No. B Height A H150-075ORGR-TB H150-100ORGR-TB H150-125ORGR-TB H250-200ORGR-TB Trade Size Height 1-1/2”-3/4” 1-21/32 1-1/2”-1” 1-25/32 1-1/2”-1-1/4” 1-25/32 2-1/2”-2” 2-1/8 Dia. (Ø) A B 2-3/4 2-3/4 2-3/4 3-3/4 15/16 1-1/16 1-1/16 1-3/16 23/32 23/32 23/32 15/16 Dimensions (in.) C D E 1-29/32 1-9/32 1-29/32 1-9/16 1-29/32 1-7/8 2-29/32 2-21/32 11/32 7/32 1/32 3/32 Material—Offset Reducer and Locknut: zinc or copper-free aluminum Insulating Throat: thermoplastic temp. rating—105°C; Flammability rating—94V-0 Sealing Ring: Nitrile (BUNA “N”) For Aluminum Offset Reducer add suffix A. (i.e. H150-125ORGRA-TB) For Chrome Plated Offset Reducer add suffix CP. (i.e. H150-125ORGRCP-TB) Dia. (Ø) Dia. (0) E Capoffs B Cat. No. A C Capoff Dia. Height H050CAP H075CAP H100CAP H125CAP H150CAP H200CAP H250CAP H300CAP H350CAP H400CAP H500CAP H600CAP Trade Size Height Diameter A Dimensions (in.) B C 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 3-1/2” 4” 5” 6” 1-13/32 1-15/32 1-11/16 1-25/32 1-13/16 1-27/32 2-9/32 2-9/16 2-9/16 2-9/16 2-23/32 3 1-7/16 1-11/16 2 2-3/8 2-3/4 3-1/4 3-3/4 4-3/8 5 5-1/2 6-5/8 7-5/8 19/32 19/32 11/16 23/32 23/32 23/32 7/8 7/8 29/32 29/32 29/32 31/32 27/32 1-1/16 1-5/16 1-21/32 1-29/32 2-3/8 2-29/32 3-1/32 4-1/32 4-1/2 5-9/16 6-5/8 3/16 3/16 1/4 1/4 1/4 1/4 1/4 11/32 11/32 11/32 11/32 11/32 Material—Capoff and Locknut: zinc or copper-free aluminum Insulating Throat: thermoplastic temp. rating—105°C; flammability rating—94V-0 Sealing Ring: Nitrile (BUNA “N”) For Aluminum Capoff add suffix A. (i.e. H050CAPA) For Chrome Plated Capoff add suffix CP. (i.e. H050CAPCP) 31 T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings Threadless Fittings/Couplings (For Threadless Rigid Metal Conduit and Intermediate Metal Conduit) 8123 Series 8130 Series Features • Steel/Malleable Iron Construction. Standard Material Nut, Gland 1/2” to 1” Steel—1-1/4” to 4” Malleable Iron Body All Malleable Iron Ring Steel (case hardened) Insulator Nylon Locknut 1/2” thru 2” Steel (hardened) 2” thru 4” Malleable Iron • Case hardened ring bites into conduit for high quality continuity and grip. Standard Finish Electro Zinc Plated & Chromate Coated • Nylon insulator firmly secured in place protects conductors and reduces wire pulling effort by as much as 50%; prevents thread damage in handling. Range • 8123 & 8120 Series Application • To connect and effectively bond threadless rigid metal conduit/intermediate metal conduit to a box or enclosure, or to couple ends of threadless conduit. • Case hardened steel locknut or malleable iron locknut designed to provide a positive bond. • Suitable for concrete tight application. 8120 Series • Raintight application. • Capable of carrying ground fault currents up to 10,000 amps RMS (1/2" through 1-1/2” size) and 20,000 amps RMS (2” and above sizes) duration of current 3 cycles. 32 • 8130 Series • All hub threads 1/2” through 4” Size Conduit 1/2” and 3/4” Size Conduit Straight Pipe (NPS) Conformity U.L. 514B CSA C22.2 No. 18.3 ANSI C80.4 NFPA 70-2008 (ANSI) NEMA FB-1 Federal Specification W-F-408 Federal Standard H-28 (Threads) T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings Nylon Insulated Threadless Fittings Cat. No. Nylon Insul. 8123 8223 8323 8423 8523 8623 8723-TB 8823-TB 8853 8973 Dimensions (in.) B Non-Insul. Conduit Size A 8121 8221 8321 8421 8521 8621 8721 8821 8851 8971 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 3-1/2” 4” 1-11/32 1-5/8 1-7/8 2-3/8 2-5/8 3-1/4 3-15/16 4-11/16 5-3/16 5-11/16 1-15/16 2 2-7/16 2-9/16 2-3/4 2-15/16 3-15/16 4-1/8 4-1/4 5 C 3/4 3/4 7/8 11/16 3/4 27/32 1-1/8 1-7/32 1-1/8 1-1/8 For Dura-Plate™ finish, add prefix 040- to Cat. No. Consult Customer Service for details. A split steel ring with diagonal serrations grips the conduit and bites into it for positive ground. Makes a permanent connection and eliminates the need for cutting a thread on the conduit. Insulation helps to guarantee continuity of service with protection of the conductor at the critical point—the fitting bushing. Malleable iron construction. Threadless Couplings Dimensions (in.) Cat. No. Size A B 8120 8220 8320 8420 8520 8620 8720 8820 8850 8970 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 3-1/2” 4” 1-9/32 1-19/32 1-7/8 2-3/8 2-5/8 3-1/4 3-15/16 4-11/16 5-3/16 5-11/16 2 2-5/16 2-11/16 2-13/16 3-5/8 3-13/16 5-3/8 5-1/2 5-1/2 5-1/2 For Dura-Plate™ finish, add prefix 040- to Cat. No. Consult Customer Service for details. Eliminate conduit threading. When tightened with a wrench they make a U.L. Listed and CSA Certified concrete-tight connection. Malleable iron. 33 T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings Threadless Short Elbows—Nylon Insulated Cat. No. Size A Dimensions (in.) B C 8130 8131 8132 8134 1/2” 3/4” 1” 1-1/2” 1-11/32 1-5/8 1-7/8 2-23/32 1-1/2 1-3/4 1-15/16 3-1/8 1/2 9/16 11/16 13/16 For Dura-Plate™ finish, add prefix 040- to Cat. No. Consult Customer Service for details. Ideal for entering enclosure or conduit body at right angles. Eliminates need to thread conduit. As with straight couplings, this fitting makes a concretetight connection. Malleable iron. 34 T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings Specifications — Set Screw Fitting/Coupling (For Threadless Rigid Metal Conduit and Intermediate Metal Conduit) Application • To connect and effectively bond threadless rigid metal conduit or intermediate metal conduit to a box or enclosure or to couple ends of threadless conduit. 8125 Series Features • Thickwall steel or malleable iron body. • Hardened hex head cup point screw to provide high quality bond. • Captive screw, will not vibrate loose. • Nylon insulated throat meets and exceeds all codes requirements for bushing: (i) Prevents thinning of insulation. (ii) Reduces installation effort. (iii) Prevents first thread damage. 8124 Series • Coupling provided with positive center stop. • Suitable for concretetight application. • Capable of carrying ground fault currents up to 10,000 amps RMS (1¼2 through 1-1/2” size) and 20,000 amps RMS (2” and above sizes). Standard Material Body 1/2” thru 2” Steel 2-1/2” thru 4” Malleable Iron Locknut 1/2” thru 2” Steel (hardened) 2-1/2” thru 4” Malleable Iron Screw Steel (hardened) Insulator Nylon Standard Finish Electro Zinc Plated & Chromate Coated. Conformity U.L. 514B CSA C22.2 No. 18.3 ANSI C80.4 NFPA 70-2008 (ANSI) NEMA FB-1 Federal Specification W-F-408 Federal Standard H-28 (Threads) 35 T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings Insulated Set-Screw Fitting Cat. No. Conduit Size A Dimensions (in.) B 8125 8225 8325 8425 8525-TB 8625 8725-TB 8825 8855 8975 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 3-1/2 4” 1-3/8 1-1/2 1-13/16 2 2-5/16 2-7/16 3-3/8 3-7/16 3-7/8 4-3/16 13/32 7/16 35/65 5/8 5/8 11/16 1 1 1-1/16 1-1/8 Sizes 1/2”-2” made of steel. Sizes 2-1/2”-4” are malleable iron. For Dura-Plate™ finish, add prefix 040- to Cat. No. Consult Customer Service for details. Eliminate conduit threading with these set screw fittings. Captive hex head screws tighten down onto conduit for positive holding strength and ground. The fittings are furnished with insulated throats reducing wire pulling effort by as much as 50%. Approved concrete-tight. Set Screw Coupling Cat. No. Conduit Size Dimensions (in.) A 8124 8224-TB 8324-TB 8424 8524 8624 8724-TB 8824-TB 8854 8974 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 3-1/2 4” 2-1/2 2-11/16 2-27/32 3 3-3/8 3-5/8 3-7/8 4-1/4 4-15/16 5-3/8 Sizes 1/2”-2” made of steel; sizes 2-1/2”-4” are malleable iron. For Dura-Plate™ finish, add prefix 040- to Cat. No. Consult Customer Service for details. Eliminate the need for threading conduit ends when joining rigid conduit with these set screw couplings. Captive hex head screws provide positive holding strength and ground continuity. Approved concrete-tight. 36 T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings Bushed Elbows Cat. No. Size A Dimensions (in.) B C 460TB 461TB 462 463 1/2” 3/4” 1” 1-1/4” 1-13/16 2-1/4 2-23/32 3-1/8 1-1/8 1-1/2 1-23/32 2-1/16 5/8 9/16 11/16 25/32 For Dura-Plate™ finish, add prefix 040- to Cat. No. Consult Customer Service for details. The noninsulated elbow has smoothly rounded shoulders to protect conductor insulation. Malleable iron. Short Elbows—Nylon Insulated The integral insulation of the insulated elbow is a guarantee that the bushing of every fitting will be smooth. Malleable iron. Cat. No. Size A Dimensions (in.) B C 4290 4291 4292 4293 4294 4295 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 1-7/32 1-7/16 1-23/32 2-7/32 2-15/32 3 1-1/4 1-5/16 1-9/16 2-1/16 2-3/16 2-9/16 1/2 9/16 11/16 13/16 13/16 13/16 For Dura-Plate™ finish, add prefix 040- to Cat. No. Consult Customer Service for details. Not U.L. Listed Short Elbows When an insulated elbow is not desired, the Noninsulated short elbow should be used. Malleable iron. Cat. No. Size A Dimensions (in.) B C 4250 4251 4252 4253 4254 4255 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 1-5/16 1-17/32 1-13/16 2-9/32 2-9/16 3-3/32 1-1/4 1-5/16 1-9/16 2-1/16 2-3/16 2-9/16 7/16 1/2 5/8 11/16 11/16 11/16 For Dura-Plate™ finish, add prefix 040- to Cat. No. Consult Customer Service for details. 37 T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings Threaded Coupling (ERICKSON® Couplings) (For Threaded Rigid Metal Conduit and Intermediate Metal Conduit) 674 Series 675AL Series Application • To couple and effectively bond threaded ends of rigid metal conduit/ intermediate metal conduit where neither length of conduit can be rotated. Standard Material 674 Series Bushing and Body Malleable Iron Ring Steel up to 2” or Malleable Iron 675AL Series Bushing and Body Aluminum Ring Aluminum Features • Malleable Iron/Steel/Copper-free Aluminum Construction. Standard Finish 674 Series: Electro Zinc Plated & Chromate Coated 675AL Series: Degreased • Free fitting threads ensure easy assembly. • Permits conduit coupling without rotating either conduit. Range • 674 Series: 3/8” thru 6” Conduit • Provides rigid in-line coupling with high quality grounding; will not loosen under vibration. • 675AL Series: 1/2” thru 6” Conduit • All straight pipe threads (NPS) • Suitable for concrete-tight application. • Capable of carrying ground fault currents up to 10,000 amps RMS (1/2” through 1-1/2” size) and up to 20,000 amps RMS (2” and above) (duration of fault current 3 cycles) (674 series tested). Conformity U.L. 514B CSA C22.2 No. 18.3 NEMA FB1 ANSI C80.4 NFPA 70-2008 (ANSI) Federal Specification W-F-408 Federal Standard H-28 (Threads) ERICKSON® Couplings Dimensions (in.) Cat. No. With an Erickson coupling, a conduit run may be completed when neither conduit can be turned. A conduit run may also be broken without taking down the whole run. Conduit joined with Erickson Couplings is rigid and in line and vibration will not loosen the connections. Mal. Iron Alum.* Size A B 674 675 676 677 678 679 680-TB 681 682 683 684 685 686 687 — 675AL 676AL 677AL 678AL 679AL 680AL 681AL 682AL 683AL 684AL 685AL† 686AL 687AL 3/8” 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 3-1/2” 4” 4-1/2” 5” 6” 1-1/8 1-15/32 1-9/16 1-29/32 2-3/8 2-5/8 3-7/32 3-3/32 4-7/16 5 5-1/2 6-1/4 6-25/32 8 1-1/8 1-1/4 1-13/32 1-5/8 1-13/16 1-31/32 2-7/32 2-11/16 2-29/32 3 3-3/16 3-15/32 3-3/4 4-1/32 * Copper-free Aluminum (less than .4% Copper). U.L. Listed and CSA Certified concrete-tight. † Not CSA Certified. 38 T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings Panel Fitting Extensions Cat. No. Size A Dimensions (in.) B C 1440 1441 1442 1443 1/2” 3/4” 1” 1-1/4” 1-1/4 1-1/4 1-3/16 1-1/4 1-3/16 1-13/32 1-21/32 2-1/8 1-7/8 1-15/16 1-15/16 2 Ideal when longer thread length is needed. Will combine with any fitting having a male thread. Male thread of panel fitting extension is 1” long. Malleable iron. Male Enlargers* Cat. No. Size A Dimensions (in.) B C 1245 1246 1244 1247 1/2” to 3/4” 3/4” to 1” 1” to 1-1/4” 1-1/4” to 1-1/2” 1-1/4 1-17/32 1-7/8 2-3/16 1-5/32 1-9/32 1-7/16 1-15/32 1/2 15/32 17/32 19/32 For Dura-Plate™ finish, add prefix 040- to Cat. No. Consult Customer Service for details. Adapt an outlet hole to the next larger size of conduit. Rough ends of conduit carefully covered by built-in bushing. Malleable iron. Female Reducers* Cat. No. Adapt any outlet to the next smaller size of conduit. Hex shoulder makes wrench tightening convenient. Malleable iron. 1250-TB 1261 1251 1262 1263 1252 1253 1254 1255 1256 1257 1258 Size A Dimensions (in.) B C 3/4” to 1/2” 1” to 1/2” 1” to 3/4” 1-1/4” to 1/2” 1-1/4” to 3/4” 1-1/4” to 1” 1-1/2” to 1-1/4” 2” to 1-1/2” 2-1/2” to 2” 3” to 2-1/2” 3-1/2” to 3” 4” to 3-1/2” 1-1/8 1-7/16 1-3/8 1-13/16 1-13/16 1-3/4 2 2-3/8 3 3-5/8 4-1/8 4-5/8 5/8 1-7/16 11/16 21/32 23/32 25/32 13/16 1-3/16 1-1/4 1-1/2 1-9/16 1-3/16 3/16 3/16 3/16 3/16 3/16 7/32 1/4 9/32 3/8 1/2 1/2 1/2 For Dura-Plate™ finish, add prefix 040- to Cat. No. Consult Customer Service for details. 39 T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings Threaded Reducers Cat. No. For reducing the threaded opening in conduit bodies or any female threaded fitting. Smooth, built-in bushing completely covers rough ends of conduit. Iron or steel construction. Steel from 600-TB thru 606-TB, also 614 & 615. Stl. or M.I. Alum. Size Dimensions (in.) A 600-TB 601-TB 602-TB 603-TB 604-TB 605-TB 606-TB 607 608 609 610 611-TB 612 613 614-TB 615-TB 600AL-TB 601AL-TB 602AL-TB 603AL-TB 604AL-TB 605AL 606AL 607AL 608AL 609AL 610AL 611AL 612AL 613AL 614AL 615AL 1/2” to 3/8” 3/4” to 1/2” 1” to 1/2” 1” to 3/4” 1-1/4” to 1/2” 1-1/4” to 3/4” 1-1/4” to 1” 1-1/2” to 1/2” 1-1/2” to 3/4” 1-1/2” to 1” 1-1/2” to 1-1/4” 2” to 1/2” 2” to 3/4” 2” to 1” 2” to 1-1/4” 2” to 1-1/2” 5/8 19/32 19/32 19/32 19/32 19/32 11/16 15/16 15/16 1-3/32 27/32 23/32 1-1/16 1-1/16 1-1/16 27/32 Reducing Washers Dimensions (in.) Cat. No. Washers reduce knockout hole in outlet box. Newly designed of galvanized steel. These washers, used in pairs, interlock and form a rib which centers the washers and conduit in the knockout. 3700 3701 3702 3703 3704 3705-TB 3706 3707 3708 3709 3710 3711 3712 3713 3714 3715-TB 3716 3717 3718 Size A B 3/4” to 3/8” 3/4” to 1/2” 1” to 3/8” 1” to 1/2” 1” to 3/4” 1-1/4” to 3/8” 1-1/4” to 1/2” 1-1/4” to 3/4” 1-1/4” to 1” 1-1/2” to 3/8” 1-1/2” to 1/2” 1-1/2” to 3/4” 1-1/2” to 1” 1-1/2” to 1-1/4” 2” to 1/2” 2” to 3/4” 2” to 1” 2” to 1-1/4” 2” to 1-1/2” 1-3/8 1-3/8 1-5/8 1-5/8 1-5/8 2 2 2 2 2-1/4 2-1/4 2-1/4 2-1/4 2-1/4 2-3/4 2-3/4 2-3/4 2-3/4 2-3/4 45/64 7/8 45/64 7/8 1-3/32 45/64 7/8 1-3/32 1-23/64 45/64 7/8 1-3/32 1-23/64 1-23/32 7/8 1-3/32 1-23/64 1-23/32 1-31/32 40 T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings Conduit Straps (For Rigid Metal Conduit and Intermediate Metal Conduit) Application • To support and securely fasten rigid metal conduit and intermediate metal to the supporting surface. 1275 Series 1276AL Series Features • Rugged malleable iron/copper-free aluminum construction—snugly fits on the conduit. • Designed to prevent accumulation of moisture and start of corrosion on vertical run of conduit (A). Conduit Strap Conduit Conduit Spacer Supporting Wall Standard Material 1275 Series Malleable Iron 1976AL Series All copper-free aluminum Standard Finish 1275 Series Hot Dipped Galvanized 1276AL Series As Cast Range • 1275 Series 3/8” through 6” conduit • 1276AL Series 1/2” through 6” conduit Conformity CSA C22.2 No. 18.3 ANSI C80.4 NFPA 70-2008 (ANSI) Pipe Straps—Malleable Iron or Aluminum Cat. No. B A C Designed to fit each size of conduit snugly. High reinforcing ribs on each side increase strength, reduce weight. Hot-dipped galvanized finish. Mal. Iron Alum. Size 1275† 1276† 1277† 1278† 1279† 1280† 1281 1282* 1283* 1284 1285* 1286** 1287 1288 1275AL 1276AL† 1277AL† 1278AL† 1279AL† 1280AL 1281AL 1282AL 1283AL 1284AL 1285AL 1286AL** 1287AL 1288AL 3/8” 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 3-1/2” 4” 4-1/2” 5” 6” * May be used with EMT of same size. † Not snap on type. U.L. not applicable. ** Not CSA Certified 41 A Dimensions (in.) B 1-15/16” 19/32” 2-11/32” 23/32” 2-11/16” 21/32” 3-3/32” 11/16” 4-1/8” 13/16” 4-1/2” 15/16” 5-3/16” 1-1/8” 5 -15/16” 1-1/2” 6-11/16” 1-5/8” 7-19/32” 1-3/4” 8-5/16” 1-7/8” 9-3/16” 1-15/16” 9-15/16” 2” 11-1/2” 2-7/16” C Screw Size 1/4” 1/2” 5/8” 13/16” 29/32” 1-17/32” 1-1/4” 1-3/4” 2-3/16” 2-3/4” 2-13/16” 2-15/16” 3-1/4” 4-1/8” 1/4” 1/4” 1/4” 1/4” 5/16” 3/8” 7/16” 1/2” 1/2” 5/8” 5/8” 5/8” 5/8” 5/8” T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings Pipe Straps—Steel C A B Elongated bolt hole makes alignment easy, even when holes in mounting surface are off center. Snap on features. Steel. Zinc plated Cat. No. Conduit Size A Dimensions (in.) B C Screw Size 1210C† 1211C 1212C 1213C 1214TB* 1215TB* 1216TB* 3/8” 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 1-15/32 2 2-5/16 3-13/16 2-31/32 3-23/32 4-7/16 3/4 3/4 3/4 3/4 1-9/16 1-13/16 2-5/16 11/16 15/16 1” 1-17/64 1-9/16 1-13/16 2-5/16 1/4” 1/4” 1/4” 1/4” 3/8” 3/8” 3/8” Not snap on type. U.L. not applicable. * Not CSA Certified. † Corrosion Resistant PVC Coated Rigid Conduit Straps B A C Malleable iron. Designed to fit each size of conduit snugly. High reinforcing ribs on each side increase strength, reduce weight. Cat. No. 1275CR 1276CR 1277CR 1278CR 1279CR 1280CR 1281CR Size Bolt Size A Dimensions (in.) B C 3/8” 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 1/4” 1/4” 1/4” 1/4” 3/8” 3/8” 1/2” 2 2-13/32 2-3/4 3-5/32 4-5/32 4-9/16 5-1/4 21/32 25/32 23/32 3/4 25/32 1 1-3/16 1/4 1/2 5/8 13/16 7/8 1-7/32 1-1/4 U.L. not applicable. 42 T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings Conduit Spacers (For Rigid Metal Conduit, Intermediate Metal Conduit and Electrical Metallic Tubing) 1350 Series 1350AL Series Application • Provides mounting surface for conduit where installation requires air space between conduit and supporting surface. Standard Material 1350 Series Malleable Iron 1350AL Series Copper-free aluminum Features • Prevents conduit rusting from wall condensation. Standard Finish 1350 Series Hot Dipped Galvanized 1350AL Series As Cast • Spacers can be stacked one atop the other facilitating installation and eliminating expensive conduit off setting (A). • Designed to cover wide range; marked with accurate size marking for proper positioning (B). 43 Range 1/2” through 6” conduit Conformity CSA C22.2 No. 18.3 ANSI C80.4 NFPA 70-2008 (ANSI) T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings Pipe Spacers Cat. No. Mal. Iron 1350 1351 1352 1353 1354 Used with T&B conduit straps to permit space between conduit and mounting surface. Eliminates need for costly offset-bending conduit and possible corrosive moisture traps when conduit is mounted directly to a surface. Hot-dipped galvanized finish, premountable and stackable to eliminate offsetting. Dimensions (in.) Alum. Size Screw Size A B 1350AL 1351AL 1352AL 1353AL 1354AL 3/8”, 1/2”, 3/4”, 1” 1-1/4”-1-1/2”-2” 2-1/2”-3” 3-1/2”-4” 4-1/2”-5”-6” #7 #12 #12 #14 #16 3” 5” 9-9/16” 7-9/16” 10-9/16” 7/8” 1-3/16” 1-3/4” 2” 2-9/16” Conforms to CEC Rule 12-012 (5) U.L. not applicable. Pipe Spacers—PVC Coated Cat. No. Corrosion resistant PVC coated malleable iron. Pre-mountable, stackable to eliminate offsetting. Spacers can be stacked for offsets on wall or into outlet box. Prevents conduit rusting from wall condensation. Eliminates offsetting of conduit. 1350CR 1351CR 1352CR 1353CR 1354CR Dimensions (in.) Conduit Size Screw Size A B 1/2”-3/4”-1” 114”-1-1/2”-2” 2-1/2”-3” 3-1/2”-4” 4-1/2”-5”-6” #7 #12 #12 #14 #16 3 5 6-9/16 7-9/16 10-9/16 7/8 3/8 1-3/4 2 2-9/16 U.L. not applicable. Conforms to CEC Rule 12-012 (5) 44 T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings Tite-Bite® Combination Couplings Armoured Cable for Threaded Rigid Dimensions (in.) Cat. No. Size A B 440-C 441 442 1/2” 3/4” 1” 1-5/8 1-3/4 2 1-27/32 2-1/8 2-17/32 A one-piece fitting that couples armoured cable or flexible conduit to threaded rigid conduit. Tite-Bite wedge holds conduit securely with a double grip. With a Chase® nipple, this fitting will connect flexible conduit to outlet boxes, allowing more wiring space in the box than the usual fitting. Malleable iron. Beam Clamps Adjustable Cat. No. Description 700TB 703* Fits Flange 2-3/4”-7-3/8” Special Bolt and 3 Nuts * Not CSA Certified Includes bolts. Steel. Conduit Supports Cat. No. Size 690TB 691TB 692TB 693TB 1/2” 3/4” 1” 1-1/4” These supports will fit any flange, tapered or straight up to 5/8” thick. The broad hook holds the conduit at any desired angle. Holds standard rigid conduit, E.M.T., or I.M.C. Malleable iron. 45 T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings Methods of Bonding and Grounding CONCRETE TIGHT CONCRETE TIGHT RAIN TIGHT Case 1: Where threaded or threadless conduit terminates into a threadless opening in a sheet metal box or enclosure with or without concentric or eccentric knockouts. Bonding jumper around concentric or eccentric rings required by CEC Rule 10-614 Threadless opening in a sheet metal box or enclosure. Method of Bonding For 120/208 volts or 120/240 volts circuits provided no unpunched rings remain around the knockout. For under or over 250 volts circuits, service equipment and hazardous locations (where applicable) provided no unpunched rings remain around the knockout. For under or over 250 volts circuits, service equipment and hazardous locations (where applicable) with or without unpunched rings around the knockout. (1) Threaded or threadless rigid metal conduit or intermediate metal conduit (2) T&B Series 8123 or 8124 Threadless Fittings (3) T&B Series 8125 Set Screw Fitting (4) T&B Series 370 or H050-TB Sealing Hub (Bullet® Hubs) (5) T&B Series 140 Locknuts (6) T&B Series 106 Bonding Locknut (7) T&B Series 3870 Bonding & Grounding Bushing (8) T&B Sta-Kon® or Color-Keyed® lug 46 T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings Methods of Bonding and Grounding (continued) CONCRETE TIGHT CONCRETE TIGHT RAIN TIGHT Threaded hub in a cast metal enclosure Case 2: Where threaded or threadless conduit terminates into a threaded hub in a cast metal enclosure. Methods of Bonding For (1) 120/208 or 120/240 volts circuits (CEC 10-610) (2) Over 250 volts circuits (CEC 10-610) (3) Service equipment (CEC 10-604) (4) Hazardous Locations 18-074 (where applicable) 18-124 (Class I, Zone 1) 18-160 (Class I, Zone 2) 18-218 (Class II, Division 1) 18-268 (Class II, Division 2) 18-316 (Class III, Division 1) 18-366 (Class III, Division 2) (1) Threaded or threadless rigid metal conduit or intermediate metal conduit. (2) T&B Series 8123 Threadless Fitting (3) T&B Series 8125 Set Screw Fitting 47 T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings Methods of Bonding and Grounding (continued) Case 3: Where threaded conduit terminates into a threadless opening in a sheet metal box or enclosure with no concentric or eccentric rings remaining around knockout. Threadless opening in a sheet metal box or enclosure Method of bonding for 120/208 volt or 120/240 volts circuits (other than service equipment). Method of bonding for over 250 volts circuits e.g. 600/347 volt systems and those operating over 600 volts (other than service equipment). Note: Any of the bonding methods described for service equipment may also be used. 48 T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings Methods of Bonding and Grounding (continued) Case 3: (cont’d) Where threaded conduit terminates into a threadless opening in a sheet metal box or enclosure with no concentric or eccentric rings remaining around knockout. (1) Threaded rigid metal conduit or intermediate metal conduit (2) T&B Series 142 Locknuts (3) T&B Series 122 Bushing Metallic (4) T&B Series 222 Bushing Plastic (5) T&B Series 106 Bonding Locknut (6) T&B Series 3650 Bonding Wedge Method of Bonding For (i) Over 250-volts circuit e.g. 347/600-volts systems and those operating over 600 volts (ii) Service equipment (iii) Hazardous locations where applicable or 49 T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings Methods of Bonding and Grounding (continued) Case 4: Where threaded conduit terminates into a threadless opening in a sheet metal box or enclosure with concentric or eccentric rings remaining around knockout. Methods of bonding for under or over 250-volts, for service equipment and for hazardous locations where applicable. Note: Bonding jumper required by CEC Rule 10-614 (1) Threaded rigid metal conduit or intermediate metal conduit (2) T&B Series 142 Locknuts (3) T&B Series 122 Bushing, Metallic (4) T&B Series 3650 Bonding Wedge (5) T&B Series 3870 Bonding & Grounding Bushing (6) T&B Typical Mechanical or Pressure Type Fitting Note: For raintight applications, a sealing ring, T&B Series 5302, may be used between outside of box or enclosure and the outside locknut. 50 T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings Methods of Bonding and Grounding (continued) — Typical Installation Using Bonding and Grounding Bushings Bonding Service Equipment (CEC Rule 10-604) Install Bonding Jumper to Assure Electrical Continuity Between Isolated Sections of Raceways (CEC Rule 10-614) Bonding required by CEC Rule 10-604 Bonding Method per CEC Rule 10-806 LOAD SIDE OF SERVICE EQUIPMENT Bonding required by CEC Rule 10-606 Bonding Method per CEC Rule 10-806 Bonding jumper required by CEC Rule 10-606 CEC Rule 10-806 (i) (ii) Installing bonding jumper around unpunched concentric or eccentric knockouts in sheet metal box or enclosure [CEC Rule 10-806]. Installing bonding jumper in hazardous locations where ‘locknut bushing’ or ‘double locknut’ type of contact is unacceptable method for bonding purposes [CEC Rule 18-074] Multiple Bonding of Service Raceways Where Service Entrance Conductors are Paralleled in Two or More Raceways, CEC Rule 10-614 SERVICE ENCLOSURE BUS BAR GROUND BUS SERVICE CONDUITS 1 T&B Series 142 Locknut 2 T&B Series 3870 Bonding & Grounding Bushing (Threaded) 3 T&B Series 5262 Sealing “O” Ring 4 T&B Typical Bolted or Pressure Lug Suggested Specifications Grounding and bonding bushings used shall be approved for the purpose and (i) Shall be of malleable iron/steel/aluminum construction adequately protected against corrosion. (ii) Bushing insulator shall be listed or certified for 150°C/302°F application with a flammability rating of 94V-O. Insulator must be positively locked in place. Insulated grounding and bonding bushing (Series 3870) Where code requires bonding and grounding of single or multiple metal conduits, or positive bonding and grounding of metal conduit to the box, enclosure or auxiliary gutter, the end of the conduit shall be equipped with an insulated metallic grounding and bonding bushing such as Series 3870 manufactured by Thomas & Betts. 51 T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings Methods of Bonding and Grounding (continued) — Typical Installation Using Thomas &Betts Bonding locknut Suitable for Bonding Raceway, EMT or Terminating Fitting to a sheet metal box or enclosure where (a) No unpunched concentric or eccentric rings remain around the knockout. (b) Ordinary locknut is unacceptable for bonding purposes such as (i) Service Equipment Enclosures CEC Rule 10-614 (ii) Bonding for circuits over 250 volts (where required) CEC Rule 10-614 (iii) Bonding in Hazardous Locations regardless of the voltage of the system CEC Rule 18-074 (1) T&B Series 142 Locknut (2) T&B Series 106 Bonding Locknuts (3) T&B Series 122 Bushing Suggested Specifications Bonding Type Locknut (Series 106) Where drawings indicate installation of a bonding type locknut to effectively bond a terminating fitting or metal conduit to a cabinet, box, enclosure or an auxiliary gutter, the locknuts installed shall be of hardened steel/malleable iron construction, electro-zinc plated, such as Series 106 manufactured by Thomas & Betts. 52 T&B Conduit Fittings Rigid and Intermediate Metal Conduit Fittings Methods of Bonding and Grounding (continued) — Typical Installations Using Thomas & Betts Bonding and Grounding Wedge Acceptable Method for Bonding Following (i) Service Equipment CEC Rule 10-614 (ii) Bonding for Circuits over 250 volts CEC Rule 10-614 (iii) Bonding in Hazardous Locations CEC Rule 18-074 When installed with a bonding jumper, acceptable method of bonding where unpunched rings remain around concentric or eccentric knockouts in sheet metal boxes or enclosures. [CEC Rule 10-614]. T&B Series 3651 Bonding & Grounding Wedge Service Enclosure Service Equipment Bonding Jumper Suggested Specifications Grounding electrode conductor Bonding and Grounding Wedge (Series 3650) Bonding and Grounding Wedges installed to effectively bond terminating fitting or metal conduit to a cabinet, box, enclosure or an auxiliary gutter or to install bonding jumper around concentric or eccentric knockouts shall be of the type as manufactured by Thomas & Betts—Series 3650. Bonding and Grounding Wedge shall be of rugged bronze/tin plated or steel/electro-zinc plated. Ground Bus Grounding electrode Conductor enclosure (Rigid Metal Conduit or Intermediate Metal Conduit) Threaded Rigid Metal Conduit or intermediate Rigid Metal Conduit Sheet Metal Box or Enclosure with unpunched concentric or eccentric rings remaining around knockout opening. Phase Conductors Equipment Bonding Jumper (1) T&B Series 142 Locknut (2) T&B Series 122 Metallic Bushing (3) T&B Series 3651 Bonding & Grounding Wedge (4)T&B Pressure (crimp type) Terminal Lug. 53 T&B Conduit Fittings Electrical Metallic Tubing (EMT) Fittings Specifications — Electrical Metallic Tubing (EMT) Ref. CEC Rule 12-1400 not exceeding 750 Volts Electrical Metallic Tubing (EMT) is similar to rigid steel conduit but is much lighter, weighing approximately 40 percent as much as rigid steel conduit of the same nominal size. EMT can be used for both exposed or concealed work provided that, during installation or afterwards, it is not subjected to severe physical damage. Use of EMT is restricted to systems not exceeding 600 volts and to nonhazardous locations except for Class II Division 2, acceptable in Class III Division 1 and Division 2 per CEC Rule 18-302 (1). Galvanized Steel EMT installed in concrete, on grade or above, generally requires no supplementary corrosion protection. However, when installed in concrete below grade level and in contact with soil or cinders, supplementary corrosion protection consisting of a protective coating of bitumastic or asphalt base paint or plastic is generally applied. EMT run in or under permanently moist cinder fill must be encased in at least two inches of cinderfree concrete unless the conduit is at least 18 inches below the fill. Aluminum EMT cannot be directly embedded in concrete containing soluble chlorides such as calcium chloride, unwashed beach sand, sea water or coral bearing aggregates. When adequately treated with a protective coating of bitumastic or asphalt base paint or plastic coating, the raceway can be installed in concrete containing chlorides. In wet locations where walls are frequently washed or where there are surfaces of absorbent material, the entire wiring system, including boxes, fittings, conduits and cables, must be supported such that there is at least 1/4 inch air space between it and the supporting surface. Fittings and couplings are required to be of concrete tight type when embedded in masonry or concrete or in dry locations and of the raintight type when installed in wet locations (CEC Rule 12-1410). Where No. 4 or larger underground conductors enter or leave a conduit, an insulating bushing with a smooth well-rounded insulating surface must be provided to protect conductors unless the terminating fitting is equipped with an insulated throat, firmly secured in place providing equivalent protection. The insulating bushing or insulating material must have a temperature rating of not less than the insulation temperature rating of installed conductors. CEC Rule 12-3022 requires that the raceways be metallically joined together into a continuous electric conductor and must be mechanically connected to all boxes, fittings and cabinets as to provide effective electrical continuity. EMT is not permitted to be threaded. Cut ends of tubing are required to be reamed. Code requires that EMT be adequately supported and restricts bends in one run to the equivalent of four quarters or 360 degrees total. Portions of this section reprinted by permission from the Canadian Electrical Code 2009 Part I. Please Note The excerpts and other material herein, whether relating to the Canadian Electrical Code 2002 Part I, the Underwriters Laboratories, Inc. listing, to industry practice or otherwise, is not intended to provide all relevant information required for use and installation. Reference to original or primary source material and data is mandatory before any application or use is made of the product. 54 For further details and complete information please refer to the following: 1. NEC Article 358…Electrical Metallic Tubing 2. ANSI C80.3…Electrical Metallic Tubing, Zinc Coated 3. U.L.797…Standards for Safety, Electrical Metallic Tubing 4. ANSI C80.4…Fittings for Rigid Metal Conduit and Electrical Metallic Tubing 5. U.L. 514, Standards for Safety, Outlet Boxes and Fittings 6. WW-C-563…Conduit, Metal, Rigid, and Bend and Elbow, Electrical Conduit, Thinwall Type (EMT) 7. W-F-408…Fittings for Conduit, Metal, Rigid, (Thickwall & Thinwall (EMT) Type) 8. NEMA FB-1…Standards Publication, Fittings and Supports for Conduit & Cable Assemblies 9. CEC Section 12-1400…Electrical Metallic Tubing 10. CSA C22.2 No. 83…Safety Standards for Electrical Metallic Tubing 11. CSA C22.2 No. 18…Safety Standards for Outlet Boxes, Conduit Boxes and Fittings T&B Conduit Fittings Electrical Metallic Tubing (EMT) Fittings Suggested Specifications for Electrical Metallic Tubing (EMT) Fittings Series 5123 Insulated EMT Fitting (Raintight) (Compression Type) Series 5120 EMT Coupling (Raintight) (Compression Type) • Ferrous Electrical Metallic Tubing (EMT) shall be of the hot dipped galvanized type conforming to applicable specifications WW-563/ANSI C80.3/U.L. 797/CSA C22.2 No. 83. EMT protected solely by enamel shall not be used. • Where lengths of EMT are coupled together or connected to boxes or enclosures or where EMT is coupled to threaded rigid metal conduit or IMC, fittings approved for intended applications shall be used, and: (1) Shall be of rugged steel/malleable iron construction electro-zinc plated inside/outside including threads. Fitting throat shall be bushed with a nylon insulator. (2) Shall be of raintight type for installations exposed to weather or wet locations such as Thomas & Betts series 5123, 5120 and 530. Raintight type fittings may be substituted for concrete tight application. • Where electrical metallic tubing and associated fittings are used as part of equipment grounding system: (1) A bonding type locknut such as Thomas & Betts series 106 shall be installed where hub type fitting terminates into a threadless opening (2) Compression ring type fittings such as Thomas & Betts series 5123 and 5120 shall be used for terminating and coupling. • EMT shall be securely fastened in place at intervals as specified by the code using straps, hangers and other supporting assemblies as indicated on plans, and as manufactured by Thomas & Betts, series 4176 straps. In wet locations or where supporting surfaces are of absorbent materials vertical and horizontal runs of conduit shall be firmly supported such that there is at least 1/4” air space between conduit and supporting surface Series 1350 Pipe Spacers • Spacers and supporting straps shall be of rugged malleable iron or steel construction, hot dipped galvanized, and conforming to requirements of Canadian Standards Association Standard C22.2 No. 18.3 as manufactured by Thomas & Betts, series 4176 straps and series 1350 spacers. Series 106 Bonding Locknut Series 4176 Pipe Straps 55 T&B Conduit Fittings Electrical Metallic Tubing (EMT) Fittings Specifications — Fittings for Electrical Metallic Tubing (EMT) Compression Type, Raintight 5123 Series* 5120 Series * 4230 Series—90° Fittings Application • To connect and effectively bond electrical metallic tubing to a box or an enclosure. Standard Material All Steel except Insulator. Insulator Thermoplastic, U.L. Rated 105°C • To provide a raintight connection between tubing and the fitting. • To couple ends of tubing. Standard Finish All Steel Parts Electro Zinc Plated & Chromate Coated Insulator As Molded Features • Rugged all steel construction. Range • Conduit Size • Rings designed to positively bond conduit to fitting; unique locknut design provides effective bond between fitting and box or enclosure; ground continuity is assured. • Hub Size 1/2” thru 2” NPS Hubs provided with straight pipe threads NPS. • Nylon insulator firmly secured in place—protects conductors, reduces wire pulling effort and prevents thread damage in handling. • Locknuts are designed with extended reach to lock fitting on to a thin box or an enclosure. • Locknuts tighten without deformation; will not vibrate loose. 56 1/2” thru 2” Conformity U.L. 514B CSA 22.2 No. 18.3 NFPA 70-2008 (ANSI) NEMA FB-1 Federal Specification W-F-408 Federal Standard H-28 (Threads) T&B Conduit Fittings EMT Fittings EMT Fittings—Nylon Insulated Dimensions (in.) Across Corners Cat. No. Size A B 5123 5223 5323 5423 5523 5623 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 1-3/64 1-21/64 1-11/16 2-1/16 2-5/16 2-25/32 1-21/32 1-27/32 1-7/8 2-11/32 2-23/32 2-13/16 U.L. Listed and CSA Certified raintight. EMT Couplings Dimensions (in.) Cat. No. Size A B 5120 5220 5320 5420 5520 5620 1/2” 1-1/16 1-5/16 1-11/16 2-1/16 2-5/16 2-3/4 1-27/32 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/8 2-1/8 2-29/32 3-1/16 3-7/32 U.L. Listed and CSA Certified raintight. EMT Fittings Dimensions (in.) Across Corners Cat. No. 5121-TB 5221 5321 5421 5521-TB 5621 Size A B 1/2” 1-1/16 1-9/16 3/4” 1” 1-1/4” 1-1/2” 2” 1-5/16 1-11/16 2-1/16 2-5/16 2-3/4 1-21/32 1-3/4 1-11/32 2-9/16 2-3/4 U.L. Listed and CSA Certified raintight. T&B E.M.T. (thinwall) fittings comply with Federal Spec. WF408B. 57 T&B Conduit Fittings EMT Fittings Short Elbows—Insulated Cat. No. 4240 4241-TB 4242 4243-TB 4244 4245 Size A Dimension (in.) B C 1/2” 1/2” 1” 1-1/4” 1-1/2” 2” 1-7/8 1-11/16 1-7/8 2-3/4 3-1/16 3-3/8 1-1/8 1-3/8 1-5/8 2-5/16 2-5/8 3-7/32 11/16 1/2 5/8 11/16 11/16 3/4 U.L. Listed and CSA Certified raintight. Ideal for cramped locations or tight corners where large radius conduit elbows will not fit or would appear unworkmanlike. Shoulders on body of 1/2” size are hex-shaped to provide positive holding for standard installation tools. Use insulated type for simple, and safe, installations. Malleable iron. CSA rated 105°C. Short Elbows Malleable Iron Cat. No. Size A Dimension (in.) B C 4230 4231 4232 4233 4234 4235 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 1-7/16 1-11/16 1-7/8 2-3/4 3-1/16 3-3/8 1-9/32 1-19/32 1-27/32 2-15/32 2-3/4 3-5/16 7/16 1/2 5/8 11/16 11/16 11/16 U.L. Listed and CSA Certified raintight. Ideal for cramped locations or tight corners where large radius conduit elbows will not fit or would appear unworkmanlike. Shoulders on body of 1/2” size are hex-shaped to provide positive holding for standard installation tools. Combination Coupling—Steel Dimension (in.) Across Corners Cat. No. Size A B 530-TB 531 532 1/2” 3/4” 1” 1-3/8 1-1/2 1-19/32 1-1/16 1-11/32 1-21/32 U.L. Listed and CSA Certified raintight. For connecting EMT to threaded rigid and intermediate metal conduit. 58 T&B Conduit Fittings EMT Fittings Pipe Straps—Steel Oval Hole for Screw Size (C) Cat. No. Size A Dimensions (in.) B C (Bolt Hole) 4159C 4160C 4161C 4162* 4163* 4164* 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 1-27/32 2-1/32 2-11/32 2-7/8 3-11/16 4-1/16 3/4 3/4 3/4 3/4 1-1/4 1-1/8 1/4 1/4 1/4 1/4 11/32 13/32 Not U.L. Listed *Not CSA Conform to CEC 12-1404 Elongated bolt hole makes alignment easy, even when holes in mounting surface are out of alignment. Snap on features hold strap in place. Pipe Straps—Malleable Iron Oval Hole for Screw Size (C) Cat. No. Size A Dimensions (in.) B C (Bolt Hole) 4176 4177 4178 4179 4180 4181 1282* 1283* 1284* 1285* 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3 3-1/2 4” 2-5/32 2-9/16 3 3-3/4 4-3/16 5-3/16 5-15/16 6-11/16 7-19/32 8-5/16 2-1/32 1-1/16 3/4 1-3/16 1-5/16 1-1/8 1-1/2 1-5/8 1-3/4 1-7/8 1/4 1/4 1/4 5/16 3/8 7/16 1/2 1/2 5/8 5/8 Not U.L. Listed. *Not CSA Conforms to CEC 12-1404 Designed to fit each size of conduit snugly. High reinforcing ribs on each side increase strength, reduce weight. Hot dipped galvanized finish. Pipe Spacers Dimensions (in.) Cat. No. Size A B 1350 1351 1352 1353 1354 1/2”, 3/4”, 1” 1-1/4”,1-1/2”, 2” 2-1/2”, 3” 3-1/2”, 4” 4-1/2”, 5”, 6” 3” 5” 9-9/16” 7-9/16” 10-9/16” 7/8” 1-3/16” 1-3/4” 2” 2-9/16” Conforms to CEC 12-012 (5). Used with T&B conduit straps to permit space between conduit and mounting surface. Eliminates need for costly offset-bending conduit and possible corrosive moisture traps when conduit is mounted directly to a surface. Malleable iron. Hot-dipped galvanized finish, pre-mountable and stackable to eliminate offsetting. 59 T&B Conduit Fittings Flexible Cord and Cable Fittings Specifications — Flexible Cord and Cables Ref. CEC Section 4 (Conductors) The Canadian Electrical Code, Flexible Cords are known by their trade names “Hard Service Cord,” “Junior Hard Service Cord” and “Vacuum Cleaner Cord.” Depending on jacket material, flexible cords listed are suitable for use where immersed in water or where occasionally or continuously in contact with oil or immersed in oil, or outdoors and in mobilhomes and recreational vehicles. Flexible cord is permitted by Code for use in portable appliances or stationary equipment requiring movement for service and repair and for wiring in cranes, hoists and elevators. Flexible cord is also permitted to be used to prevent transmission of noise or vibration. Flexible cord is not permitted as a substitute for fixed wiring of structures or where concealed behind building walls, ceilings or floors. Running flexible cord through holes in walls, ceilings, floors or through doorways, windows or similar openings is also prohibited. CEC Section 4 requires that flexible cords be so connected to devices and to fittings that tension is not transmitted to joints or terminal screws. Use of suitable strain relief fittings designed for the purpose is one of the recommended alternatives. Please refer to the following for further details and complete information: 1. U.L. 62, ANSI C33.1…Safety Standard for Flexible Cord and Fixture Wire 2. U.L. 514B, Safety Standard for Outlet Boxes and Fittings 3. CEC Section 4…Conductors 4.010…Uses of Flexible Cord 4.038…Uses of Portable Power Cable 12-010 (4)…Flexible Cords in Ducts and Plenum Chambers 22-108 (2)…Bonding conductor for Flexible Cords for Portable Equipment Portable Stage Equipment 50-016…Flexible Cord for Attachment Plugs and Similar Wiring Devices 70-108…Power Supply Cord-FactoryBuilt Relocatable Structures and Nonrelocatable Structures 76-002…Temporary Wiring 76-010…Feeders 78-058 (2)…Marinas and Yacht Clubs 78-104 (2)…Marine Wharves, Structures, and Fishing Harbourgs 4. CSA C22.2 No. 49…Safety Standards for Flexible Cords and Cables and Fixture Wires 5. CSA C22.2 No. 18…Safety Standards for Outlet Boxes, Conduit Boxes and Fittings Following is a brief description of the three cords. 44-350 (1) (b)…Flexible Cords for Hard Service Cord Junior Hard Service Cord Vacuum Cleaner Cord Extra Hard Pendant, Portable Hard Pendant, Portable Light Pendant, Portable Up to 600 volts Up to 300 volts Up to 300 volts Copper (Stranded) Copper (Stranded) Copper (Stranded) 4. Type Designation (Depends on Jacket Material) i. Rubber Jacket ii. Oil Resistant Rubber Jacket iii. Thermoplastic Jacket Type S Type SO Type ST Type SJ Type SJO Type SJT Type SV Type SVO Type SVT iv. Oil Resistant Thermoplastic Jacket Type STO Type SJTO Type SVTO 1. Use 2. Voltage Rating 3. Conductor Material Please Note The excerpts and other material herein, whether relating to the Canadian Electrical Code 2009 Part I, the Underwriters Laboratories, Inc. listing, to industry practice or otherwise, is not intended to provide all relevant information required for use and installation. Reference to original or primary source material and data is mandatory before any application or use is made of the product. 60 T&B Conduit Fittings Flexible Cord and Cable Fittings Suggested Specifications for Flexible Cord and Cable Fittings • Flexible cord or cable and associated fittings shall be suitable for conditions of use and location and approved for the purpose by a nationally recognized testing laboratory, inspection agency or product evaluation organization. 2520 and 2530 Series Liquidtight Flexible Cord & Cable Fittings 2920NM Series Nonmetallic Liquidtight Flexible Cord & Cable Fittings The Ranger™ Series 2631 Series Liquidtight Flexible Cord & Cable Fittings 2920AL Series Aluminum Liquidtight Flexible Cord & Cable Fittings The Ranger™ Series • Where flexible cord or cable exposed to intermittent or constant moisture and subjected to mechanical strain is terminated into a threaded or threadless opening, terminating fittings shall be of watertight strain relief type such as Thomas & Betts series 2920, 2920AL, 2920NM, 2520, 2631 or 2672. Fittings shall be equipped with a beveled moisture resistant/oil resistant synthetic rubber bushing. 2672 Series Flexible Cord Fittings (Plastic) 2920S Series Steel Liquidtight Flexible Cord & Cable Fittings The Ranger™ Series • Where space is limited inside the enclosure, a female hub type fitting such as Thomas & Betts series 2631 shall be furnished. A captive resilient sealing ‘O’ ring shall be included to positively protect against damage from overtorquing. 2920SST Series Stainless Steel Liquidtight Flexible Cord & Cable Fittings TCF Series Aluminum Tray/Cord Fitting 61 • Flexible cord or cable shall be so connected to the device or fitting that tension will not be transmitted to joints or terminal screws. Sufficient slack shall be provided to avoid sharp flexing and straining. Cord or cable shall be installed in such a manner that liquid will tend to run off the surface instead of draining towards the fitting. T&B Conduit Fittings Flexible Cord and Cable Fittings Suggested Specifications for Flexible Cord and Cable Fittings—continued Series 3300 Nonmetallic Sheathed Cable & Flexible Cord Fitting Series 1942 Insulated Nipple Series 3210 Knockout Bushings Series 5262 Sealing Gasket • Where flexible cord or cable exposed to moisture is terminated into a threadless opening using male threaded hub type fittings such as Thomas & Betts series 2520 or 2920, a suitable moisture resistant/oil resistant synthetic rubber gasket such as Thomas & Betts series 5262 shall be provided between the outside of box or enclosure and fitting shoulder. Resilient gasket shall be adequately protected by and permanently bonded to a metallic retainer. • Where exposed to environmental conditions that are more than normally corrosive, watertight strain relief fittings shall be of high impact thermoplastic construction such as Thomas & Betts series 2672 or 2920NM. • Where flexible cord or cable passes through either factory or field punched, cut or drilled holes in metal members, the cord or cable shall be protected by thermoplastic bushing such as Thomas & Betts series 3210, 3300. Bushing shall be firmly secured in opening. Nylon bushed metallic fittings such as Thomas & Betts series 1942 may be substituted as required. • For wet location, fittings furnished with synthetic rubber bushing such as Thomas & Betts series 2530 or 2672 shall be installed. 62 T&B Conduit Fittings Flexible Cord and Cable Fittings How to Select T&B Flexible Cord Fittings Step 1. Determine Diameter Range in chart by using cord size and type or by measuring the diameter of your cord. Cat. No. Straight 90° 2671 2680 Cat. No. Hub Size 3/8 Step 2. Determine catalogue number by choosing the hub size and type (straight or 90°) for the diameter range determined by step 1. Diameter Range .125-.275 This chart can be used as a guide for selecting the proper fitting for the U.L. Listed and CSA Certified cords. Cords vary in sizes and cord diameter should be measured whenever possible. SV, SVO, SVT, SVTO Cord Sizes 18-2, 18-3 90° Hub Size Diameter Range 2920NM 2930NM 4960NM 4970NM 1/2 3/4 .125-.375 18-2, 18-3* 2921NM 2931NM 2940NM 4961NM 4971NM — 1/2 3/4 1 .310-.560 18-3, 18-4*, 18-5, 16-2* 18-3, 18-4, 18-5, 18-6, 18-7* 16-3, 16-4, 16-5, 16-6*, 14-2, 14-3, 14-4, 12-2, 12-3, 12-4, 10-2 2922NM 2932NM 2941NM — 4972NM — 1/2 3/4 1 .500-.750 16-5, 16-6, 14-2, 14-3, 14-4, 14-5, 12-2, 12-3, 12-4, 12-5, 10-2, 10-3, 10-4, 8-2 12-4, 10-2, 10-3, 10-4 2942NM — 1 .700-.950 10-4, 10-5, 8-3, 8-4 — 2688 1 .560-.690 14-3*, 14-4, 14-5*, 12-2, 12-3, 12-4*, 10-2, 10-3* 10-2*, 10-3, 10-4 — 2685 1 .660-.780 14-5, 12-4*, 12-5, 10-3*, 10-4 10-4 2696 — — 2686 3/4 1 .770-.895 10-5, 8-2, 8-3* 2678 2687 1 .870-1.020 8-3*, 8-4* 2699 2702 — — 1 1-1/4 .890-1.090 8-4, 8-5*, 6-2, 6-3*, 6-4*, 4-2* 2703 — 1-1/4 2704 — 1-1/4 1.270-1.470 4-4, 2-2* 2705 — 1-1/2 .890-1.150 8-4, 8-5, 6-2, 6-3, 6-4*, 4-2* 2706 — 1-1/2 1.140-1.400 6-5, 6-4*, 4-2*, 4-3, 4-4*, 2-2, 2-3* 2707 — 1-1/2 1.390-1.650 4-4*, 2-3*, 2-4 2708 — 2 1.190-1.530 6-5, 4-2*, 4-3, 4-4, 2-2, 2-3, 2-4* 2709 — 2 1.520-1.860 2-4* 2710 — 2 1.850-2.190 Straight S, SO, ST, STO Cord Sizes 4-2*, 4-3, 2-2* * Actual cord diameter must be determined before proper fitting can be selected. Measure cord, if available, or refer to cord manufacturer’s catalogue. 63 SJO, SJT, SJTO, SJ Cord Sizes 18-2, 18-3, 18-4, 16-2, 16-3, 16-4*, 14-2, 14-3* T&B Conduit Fittings Flexible Cord and Cable Fittings Flexible Cord and Power Cable Chart Type of Cord AWG Size of Conductors Number of Conductors and Approximate O.D. (in.) 2 Conductor 3 Conductor 4 Conductor SV, SVO, SVT 18 .250 .260 — SJ, SJO, SJT, SJTO 18 16 14 .300 .330 .375 .330 .360 .395 .360 .390 .420 S, SO, ST, STO, and Portable Power Cables 18 16 14 12 10 8 6 4 3 2 1 1/0 2/0 3/0 4/0 250 14 12 10 .385 .400 .530 .600 .640 .700-.840 .820-.930 1.080 1.170 1.270 1.440 1.520 1.650 1.770 1.920 2.160 — — — .400 .425 .560 .635 .690 .750-.910 .885-1.010 1.170 1.240 1.340 1.510 1.650 1.750 1.890 2.070 2.390 — — — .430 .480 .605 .665 .745 .820-.990 .975-1.100 1.270 1.340 1.480 1.680 1.790 1.930 2.070 2.260 — .410 .450 .530 8 6 4 2 — — — — — — — — .670 .850 .950 1.000 Bus Drop Cables Note: The above dimensions are approximate and may vary depending upon the manufacturer. 64 T&B Conduit Fittings Flexible Cord and cable Fittings Specifications — Liquidtight Flexible Cord and Cable Fittings Application Standard Material • A liquidtight fittings to connect flexible cord or power cable to a box or enclosure and provide adequate strain relief. Gland, Body Retaining Ring Bushing ‘O’ Ring Features • Liquidtight connection with box or enclosure is assured by: (1) Taper threaded hub on 2520 series for female hub application (A). (2) Using sealing ring series 5262 with 2520 series for knockout application (B). (3) Captivated sealing ‘O’ ring on 2631 series (C). 2520 Series 2631 Series • Neoprene bushing makes liquidtight installation; applies pressure against cable the full length of bushing (D). • Thermoplastic or stainless steel retaining ring (E). (1) Will not abrade cord/cable jacket. (2) Reduces installing torque effort. Steel/Malleable Iron/Zinc Die Cast Thermoplastic/ Stainless Steel Neoprene Buna N Standard Finish Electro Zinc Plated & Chromate Coated Range • 2520 Series, straight 0.125” outside diameter to 3.200” outside diameter Cord or Cable • 2200 Series, 45° 0.125” outside diameter to 1.485” outside diameter Cord or Cable • 2267 Series, 90° 0.125” outsidediameter to 1.875” outside diameter Cord or Cable Cord/Cable Type S, SO, SV, ST, STO, SJ, SJO, SJT, SJTO, SVO & SVT Conformity • U.L. Listed for liquidtightness, strain relief and as an outlet bushing; CSA certified watertight. Gland Gland Retaining Ring (E) Bushing (D) Retaining Ring (E) Bushing (D) Body Body (C) (A) Sealing Gasket (B) 2520 Series Nipple 2631 Series 65 U.L. 514B CSA C22.2 No. 18.3 NFPA 70-2008 (ANSI) T&B Conduit Fittings Flexible Cord and Cable Fittings Liquidtight Strain Relief Fittings Throat Dia. Fig. 1 Throat Dia. Fig. 2 Cat. No. Cable Size Range min.-max. Hub Size Throat Dia. (min.) 2516† 2517† 2518† 2519†** (.060-.125) (.120-.250) (.060-.150) (.150-.300) 1/4” 1/4” 3/8” 3/8” 2520 2521 2522 2523 2524* 2525* (.125-.250) (.250-.375) (.375-.500) (.450-.560) (.500-.625) (.625-.750) 2530 2531 2532 2534 2535 2536* Dimensions (in.) B C Fig. A 23/64” 23/64” 29/64” 29/64” 2 2 2 2 53/64 53/64 31/32 31/32 1-7/16 1-7/16 1-1/2 1-1/2 15/32 15/32 15/32 15/32 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 9/16” 9/16” 9/16” 9/16” 5/8” 5/8” 1 1 1 1 1 1 1-5/32 1-11/16 1-5/32 1-11/16 1-5/32 1-11/16 1-5/32 1-11/16 1-3/8 1-3/4 1-3/8 1-3/4 5/8 5/8 5/8 5/8 5/8 5/8 (.125-.250) (.250-.375) (.375-.500) (.500-.625) (.625-.750) (.750-.880) 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 13/16” 13/16” 13/16” 13/16” 13/16” 3/4” 1 1 1 1 1 1 1-3/8 1-3/4 1-3/8 1-3/4 1-3/8 1-3/4 1-3/8 1-3/4 1-3/8 1-3/4 1-11/161-15/16 9/16 9/16 9/16 9/16 9/16 5/8 2541 2542 2544 2545 2546 2547 2548* 2549* (.250-.375) (.375-.500) (.500-.625) (.625-.750) (.750-.875) (.875-.985) (.880-1.065) (1.065-1.205) 1” 1” 1” 1” 1” 1” 1” 1” 49/64” 49/64” 49/64” 49/64” 63/64” 63/64” 29/32” 29/32” 1 1 1 1 1 1 1 1 1-3/8 1-23/32 1-3/8 1-23/32 1-3/8 1-23/32 1-3/8 1-23/32 1-11/16 1-7/8 1-11/16 1-7/8 2-3/32 2-3/8 2-3/32 2-3/8 9/16 9/16 9/16 9/16 23/32 9/16 25/32 25/32 2558 2559 2556* 2557* (.880-1.065) (1.065-1.205) (1.187-1.375) (1.375-1.485) 1-1/4” 1-1/4” 1-1/4” 1-1/4” 1-17/64” 1-17/64” 1-1/4” 1-1/4” 1 1 1 1 2-3/32 2-5/32 2-3/32 2-5/32 2-11/32 2-1/2 2-11/32 2-1/2 13/16 13/16 13/16 13/16 2562 2563 2564 2565* (.812-1.000) (1.000-1.187) (1.187-1.375) (1.375-1.625) 1-1/2” 1-1/2” 1-1/2” 1-1/2” 1-7/16” 1-7/16” 1-7/16” 1-29/64” 1 1 1 1 2-11/32 2-1/2 2-11/32 2-7/16 2-11/32 2-7/16 2-13/16 2-5/8 11/16 11/16 11/16 13/16 2573 2574 2575 2576* 2577* (1.125-1.375) (1.375-1.625) (1.625-1.875) (1.750-1.965) (1.937-2.187) 2” 2” 2” 2” 2” 1-7/8” 1-7/8” 1-7/8” 1-29/32” 1-29/32” 1 1 1 1 1 2-13/16 2-13/16 2-13/16 3-7/32 3-7/32 2-5/8 2-5/8 2-5/8 3-1/2 3-1/2 13/16 11/16 11/16 27/32 27/32 2584 2585* 2586* 2587* (1.750-1.965) (1.937-2.187) (2.156-2.360) (2.350-2.565) 2-1/2” 2-1/2” 2-1/2” 2-1/2” 2” 2” 2-5/32” 2-5/32” 1 1 1 1 3-7/32 3-7/32 3-15/16 3-15/16 3-3/4 3-3/4 4-1/4 4-1/4 1-1/32 1-1/32 1-1/32 1-1/32 2592 2593 2594 2595* 2596* (2.156-2.360) (2.350-2.565) (2.535-2.750) (2.735-2.985) (2.970-3.220) 3” 3” 3” 3” 3” 2-13/32” 2-13/32” 2-13/32” 2-13/16” 2-13/16” 1 1 1 1 1 3-15/16 4-1/4 1-1/32 3-15/16 4-1/4 1-1/32 3-15/16 4-1/4 1-1/32 4-11/164-13/16 1-1/8 4-11/164-13/16 1-1/8 * Remove sufficient outer covering of cable to permit conductors to pass thru fitting body. † U.L. not applicable. ** Not CSA Certified. Complies with JIC standards. U.L. Listed as liquidtight strain relief, and outlet bushing. CSA certified watertight when used with 5262 Series Sealing Ring. Gasket (Sold separately). Temperature rating: 105°C. For Wiremesh Grips refer to page 80. 5262 Series Sealing Ring Gasket sold separately 66 T&B Conduit Fittings Flexible Cord and Cable Fittings Strain Relief Fittings Swing Radius 90° with neoprene bushings, tapered hub threads, malleable iron. A Dimensions (in.) B C 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1-5/32 1-5/32 1-5/32 1-5/32 1-3/8 1-3/8 1-23/32 1-23/32 1-23/32 1-23/32 1-11/16 1-11/16 5/8 5/8 5/8 5/8 9/16 9/16 19/32 19/32 19/32 19/32 39/64 39/64 (.125-.250) (.250-.375) (.375-.500) (.500-.625) (.620-.750) (.750-.880) 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 1-3/8 1-3/8 1-3/8 1-3/8 1-3/8 1-11/16 1-3/4 1-5/8 1-5/8 1-5/8 1-5/8 1-31/32 41/64 41/64 41/64 41/64 41/64 9/16 25/32 25/32 25/32 25/32 25/32 25/32 2254 2255 2256* 2275 2276 2257* 2258* (.375-.500) (.500-.625) (.625-.750) (.750-.875) (.875-.985) (.880-1.065) (1.065-1.205) 1” 1” 1” 1” 1” 1” 1” 1-3/8 1-3/8 1-3/8 1-11/16 1-11/16 2-3/32 2-3/32 2 2 2 2 2 2-21/32 2-21/32 13/16 13/16 13/16 13/16 13/16 25/32 25/32 1 1 1 1 1 15/16 15/16 2277 2278 2279* 2280* (.880-1.065) (1.065-1.205) (1.187-1.375) (1.375-1.485) 1-1/4” 1-1/4” 1-1/4” 1-1/4” 2-3/32 2-3/32 2-11/32 2-11/32 2-7/8 2-7/8 2-13/16 2-13/16 27/32 27/32 13/16 13/16 1-5/16 1-5/16 1-11/32 1-11/32 2281 2282 2283* 2284 2285 2286 (.812-1.000) (1.000-1.187) (1.187-1.375) (1.125-1.375) (1.375-1.625) (1.625-1.875) 1-1/2” 1-1/2” 1-1/2” 2” 2” 2” 2-11/32 2-11/32 2-11/32 2-13/16 2-13/16 2-13/16 2-7/8 2-7/8 2-7/8 3-1/4 3-1/4 3-1/4 13/16 13/16 13/16 27/32 27/32 27/32 1-15/32 1-15/32 1-15/32 1-31/32 1-31/32 1-31/32 Cat. No. Cable Size min.-max. 2267 2268 2269 2270 2250* 2251* (.125-.250) (.250-.375) (.375-.500) (.450-.560) (.500-.625) (.625-.750) 2252 2271 2272 2273 2274* 2253* Hub Size Throat Dia. * Remove sufficient outer covering of cable to permit conductors to pass through fitting body. Complies with J.I.C. standards and Federal Specs W-F-406B, W-F-408B. Meets Coast Guard CG293 For Wiremesh Grips refer to page 80. 67 T&B Conduit Fittings Flexible Cord and Cable Fittings Strain Relief Fittings Swing Radius 45° with neoprene bushings, tapered hub threads, malleable iron. A Dimensions (in.) B 1/2” 1/2” 1/2” 1/2” 1/2” 1/2” 1-5/32 1-5/32 1-5/32 1-5/32 1-3/8 1-3/8 1-9/32 1-9/32 1-9/32 1-9/32 1-13/32 1-13/32 9/16 9/16 9/16 9/16 9/16 9/16 37/64 37/64 37/64 37/64 37/64 37/64 (.125-.250) (.250-.375) (.375-.500) (.500-.625) (.625-.750) (.750-.880) 3/4” 3/4” 3/4” 3/4” 3/4” 3/4” 1-3/8 1-3/8 1-3/8 1-3/8 1-3/8 1-11/16 1-13/32 1-13/32 1-13/32 1-13/32 1-13/32 1-1/2 5/8 5/8 5/8 5/8 5/8 1-1/2 25/32 25/32 25/32 25/32 25/32 3/4 2213 2214 2215 2216 2217* 2218* 2219* (.375-.500) (.500-.625) (.625-.750) (.750-.875) (.875-.985) (.880-1.065) (1.065-1.205) 1” 1” 1” 1” 1” 1” 1” 1-3/8 1-3/8 1-3/8 1-11/16 1-11/16 2-3/32 2-3/32 1-1/2 1-1/2 1-1/2 1-15/32 1-15/32 1-31/32 1-31/32 25/32 25/32 25/32 25/32 25/32 25/32 25/32 15/16 15/16 15/16 15/16 15/16 15/16 15/16 2220-TB* 2221* 2222* 2223* (.880-1.065) (1.065-1.205) (1.187-1.375) (1.375-1.485) 1-1/4” 1-1/4” 1-1/4” 1-1/4” 2-3/32 2-3/32 2-11/32 2-11/32 1-29/32 1-29/32 2-1/4 2-1/4 13/16 13/16 13/16 13/16 1-5/16 1-5/16 1-21/64 1-21/64 Cat. No. Cable Size min.-max. 2200 2201 2202 2203 2204* 2205* (.125-.250) (.250-.375) (.375-.500) (.450-.560) (.500-.625) (.625-.750) 2206-TB 2207-TB 2208-TB 2209 2210 2211* Hub Size C Throat Dia. * Remove sufficient outer covering of cable to permit conductors to pass through fitting body. U.L. Listed as liquidtight strain relief, and outlet bushing. CSA certified watertight. For Wiremesh Grips refer to page 80. 68 T&B Conduit Fittings Flexible Cord and Cable fittings ® CHASE Liquidtight Cord Fittings Cat. No. Cable Size Range min.-max. Hub Size Throat Diam. 2631 2632 2633 2634 (.125-.250) (.250-.375) (.375-.500) (.450-.560) 1/2” 1/2” 1/2” 1/2” 2637 2638 2639 2640 2641 (.125-.250) (.250-.375) (.375-.500) (.500-.625) (.625-.750) 3/4” 3/4” 3/4” 3/4” 3/4” Dimensions (in.) A B 9/16” 9/16” 9/16” 9/16” 1-1/16 1-1/16 1-1/16 1-1/16 1-5/8 1-5/8 1-5/8 1-5/8 25/32” 25/32” 25/32” 25/32” 25/32” 1-3/8 1-3/8 1-3/8 1-3/8 1-3/8 1-3/16 1-3/16 1-3/16 1-3/16 1-3/16 CSA certified watertight.U.L. Listed as liquidtight strain relief, and outlet bushing. Temperature Rating: 105°C. Chase Liquidtight Cord Fittings are ideal for installation where space is limited inside the enclosure. Multi-Hole Cord Grip B C A Cat. No. Hub Size No. of Diam. Cord Diam. A Dimensions (in.) B C 2520-2 2530-2 2531-2 2531-3 2541-2* 1/2” 3/4” 3/4” 3/4” 1” 2 2 2 3 2 .220 .220 .260 .260 .300 1.125 1.375 1.375 1.375 1.625 1.687 1.750 1.750 1.750 1.718 .625 .625 .625 .625 .781 2542-2* 2540-3 2541-3 2540-4 2555-2 1” 1” 1” 1” 1-1/4” 2 3 3 4 2 .375 .225 .300 .220 .500 1.625 1.625 1.625 1.625 2.093 1.718 1.718 1.718 1.718 2.375 .781 .781 .781 .781 .812 Range of cord diameter ±.010”. In many applications you have only room for one fitting but you need to run two cables, for example, proximity switches. Now you can provide strain relief and liquidtight protection with T&B’s new multi-hole liquidtight strain relief fittings. With the ever increasing number of signal cables, now you have a solution to the problem of how to strain relieve multiple cables in one fitting. *UL Listed only Temperature Rating: 105°C. 69 T&B Conduit Fittings Flexible Cord and Cable Fittings The Ranger® Series — Liquidtight Strain Relief Fittings The only fitting to take a .250 inch cable range. New materials and computer aided designs helped T&B develop a strain relief fitting that will take twice the cable range of ordinary strain relief fittings. Application Range A liquidtight fitting to secure flexible cord Series or power cable to a box or enclosure .125” thru .950” 2920S and provide strain relief. 4920 • Extended range with superior strain relief. • Gland nut designed to restrict cable bending. 1/2 1/2 1/2 1/2 1/2 1/2 4960 2920AL 4960AL 2920NM Features • Reduced overall size, fits into tighter spaces. Hub Size .125 thru .750” 4960NM thru thru thru thru thru thru 1” 1” 1” 1” 1” 1” 1/2 thru 3/4” Standard Material/Finish 2920S Series 4920 Series 4960 Series 2920NM Series 4960NM Series 2920AL Series 4960AL Series Body Steel (ST) 45° & 90° (Malleable Iron) Nylon (Weather Stabilized) Aluminum (ST) Malleable Iron (90°) Gland Steel Nylon (Weather Stabilized) Aluminum Plastic Nylon (Weather Stabilized) Aluminum Santoprene Oil Resistant Elastomer Aluminum Grip Bushing Liquidtight Strain Relief Fittings—Straight A B C Cat. No. Hub Size Throat Dia. Cord Range min.-max. A Dimensions (in.) B C 2920S 2921S 2922S* 1/2 1/2 1/2 9/16 9/16 9/16 .125-.375 .310-.560 .500-.750 1-1/8 1-1/8 1-3/8 1-3/4 1-3/4 1-3/4 5/8 5/8 5/8 2930S 2931S 2932S 3/4 3/4 3/4 13/16 13/16 13/16 .125-.375 .310-.560 .500-.750 1-3/8 1-3/8 1-3/8 1-25/32 1-25/32 1-25/32 3/4 3/4 3/4 2940S 2941S 2942S 1 1 1 1-1/16 1-1/16 31/32 .310-.560 .500-.750 .700-.950 1-3/8 1-3/8 1-5/8 1-3/4 1-3/4 1-7/8 1-3/16 1-3/16 1-3/16 *It may be necessary to remove sufficient outer covering of cable to permit conducters to pass through the fitting body. Liquidtight Strain Relief Fittings A B C Cat. No. Hub Size Throat Dia. Color Range min.-max. A Dimensions (in.) B M 2920 2921 2922 1/2 1/2 1/2 9/16 9/16 9/16 .125-.375 .310-.560 .500-.750 1-1/8 1-1/8 1-3/8 1-3/4 1-3/4 1-3/4 5/8 5/8 5/8 2930 2931 2932 3/4 3/4 3/4 13/16 13/16 13/16 .125-.375 .310-.560 .500-.750 1-3/8 1-3/8 1-3/8 1-25/32 1-25/32 1-25/32 3/4 3/4 3/4 2940 2941 2942 1 1 1 1-1/16 1-1/16 31/32 .310-.560 .500-.750 .700-.950 1-3/8 1-3/8 1-5/8 1-3/4 1-3/4 1-7/8 1-3/16 1-3/16 1-3/16 70 T&B Conduit Fittings Flexible Cord and Cable Fittings The Ranger® Series Liquidtight Strain Relief Fittings—45° Angle Cat. No. Hub Size Throat Dia. Cord Range A Dimensions (in.) B C 4920 4921 4922 1/2 1/2 1/2 37/64 37/64 37/64 .125-.375 .310-.560 .500-.750 1-1/8 1-1/8 1-3/8 1-5/16 1-5/16 1-7/16 9/16 9/16 9/16 4932 4933 3/4 3/4 25/32 25/32 .500-.750 .700-.950 1-3/8 1-5/8 1-7/16 1-17/32 5/8 1-1/2 Liquidtight Strain Relief Fittings—90° Angle Swing Radius Cat. No. Hub Size Throat Dia. Cord Range A Dimensions (in.) B C 4960 4961 4962 1/2 1/2 1/2 19/32 19/32 19/32 .125-.375 .310-.560 .500-.750 1-1/8 1-1/8 1-3/8 1-3/4 1-3/4 1-24/64 5/8 5/8 5/8 4970 4971 4972 3/4 3/4 3/4 25/32 25/32 25/32 .125-.375 .310-.560 .500-.750 1-3/8 1-3/8 1-3/8 1-25/32 1-25/32 1-25/32 11/16 11/16 11/16 71 T&B Conduit Fittings Flexible Cord and Cable Fittings Aluminum Liquidtight Strain Relief Fittings— Straight Body and gland nut are aluminum. Cat. No. Hub Size Throat Diam. Cord Range A Dimensions (in.) B C 2920AL 2921AL 2922AL* 1/2 1/2 1/2 9/16 9/16 9/16 .125-.375 .310-.560 .500-.750 1-1/8 1-1/8 1-5/16 1-3/4 1-3/4 1-3/4 5/8 5/8 5/8 2930AL 2931AL 2932AL 3/4 3/4 3/4 13/16 13/16 13/16 .125-.375 .310-.560 .500-.750 1-5/16 1-5/16 1-5/16 1-25/32 1-25/32 1-25/32 3/8 3/4 3/4 2940AL 2941AL 2942AL 1 1 1 1-1/16 1-1/16 31/32 .310-.560 .500-.750 .700-.950 1-5/16 1-5/16 1-9/16 1-3/4 1-3/4 1-7/8 1-1/16 1-1/16 31/32 * It may be necessary to remove sufficient outer covering of cable to permit conductors to pass through fitting body. Aluminum Liquidtight Strain Relief Fittings— 90° Elbow Across Corners Body: malleable iron Gland Nut: aluminum Dimensions (in.) B C Trade or Hub Size Throat Diam. Cord Range 4960AL 4961AL 4962AL* 1/2 1/2 1/2 9/16 9/16 9/16 .125-.375 .360-.560 .500-.750 1-1/8 1-3/4 5/8 1-1/8 1-3/4 5/8 1-5/16 1-23/64 5/8 4970AL 4971AL 4972AL 3/4 3/4 3/4 25/32 25/32 25/32 .125-.375 .310-.560 .500-.750 1-5/16 1-25/32 11/16 1-15/32 1-5/16 1-25/32 11/16 1-15/32 1-5/16 1-25/32 11/16 1-15/32 4980AL 4981AL 4982AL 1 1 1 15/16 15/16 15/16 .310-.560 .500-.750 .700-.950 1-5/16 2-1/32 13/16 1-5/16 2-1/32 13/16 1-9/16 2-11/16 13/16 Cat. No. A D 1-5/16 1-5/16 1-3/8 1-3/4 1-3/4 2 * It may be necessary to remove sufficient outer covering of cable to permit conductors to pass through fitting body. 72 T&B Conduit Fittings T&B Ranger® Stainless Steel Liquidtight Cord Fittings Beveled Rubber Bushing Ensures Superior Compression and Sealing Food Processing Pharmaceutical Processing Pulp & Paper Mills Wastewater Treatment Saltwater Applications Petrochemical Refining Type 304 Stainless Steel Construction for Your Harshest Environments! Until now, there has been no ideal solution for liquidtight connections of portable cord to a box or enclosure in corrosive environments. Steel fittings rust and nonmetallic fittings cannot withstand high temperatures or ultraviolet exposure. In response to customer demand, Thomas & Betts has developed the latest addition to its high-performance line of T&B Ranger® Cord Fittings. Made of Type 304 stainless steel, T&B Ranger® Stainless Steel Liquidtight Cord Fittings stand up to highly corrosive environments – such as washdown areas in food and beverage or pharmaceutical processing – as well as high temperatures and UV exposure. Like all T&B Ranger® Liquidtight Cord Fittings, the new stainless steel fittings offer twice the cord diameter range of similar fittings, so you can do more with fewer sizes to order and stock. They form a non-slip mechanical grip, providing a liquidtight seal and the strain relief required for flexible portable cord connections. Also available in other materials to meet all your cord-fitting needs! • 2920 Series steel/malleable iron in straight, 45º and 90º • 2920AL Series aluminum in straight and 90º • Each fitting covers a 0.25” cord diameter range – twice that of ordinary strain relief fittings • Superior corrosion resistance in washdown areas and other corrosive environments • Stands up to heat and UV exposure better than non-metallic fittings • Beveled, moisture and oil resistant synthetic rubber bushing system ensures superior compression and sealing of fitting to cord • Bushing marked with cord range for easy Identification out of box • 2920NM Series non-metallic in straight and 90º T&B Stainless Steel Cord Fittings – 1/4” - 3/8” Hub Sizes Catalogue Number Dimensions (in.) Hub Size (in.) Cord Dia. Range (in.) A B C 2918SST 1/4 0.118 - 0.256 1.000 0.250 0.625 2919SST 3/8 0.157 - 0.315 1.313 0.438 0.750 A 1.935 1.935 2.003 2.063 2.063 2.063 2.178 2.218 2.218 Dimensions (in.) B 0.610 0.610 0.610 0.630 0.630 0.630 0.785 0.785 0.785 C 1.125 1.125 1.125 1.125 1.125 1.125 1.500 1.500 1.500 T&B Stainless Steel Cord Fittings – 1/2” - 1” Hub Sizes Catalogue Number 2920SST 2921SST 2922SST 2930SST 2931SST 2932SST 2940SST 2941SST 2942SST Hub Size (in.) Cord Dia. Range (in.) 1/2 1/2 1/2 3/4 3/4 3/4 1 1 1 0.125 - 0.375 0.310 – 0.560 0.500 – 0.750 0.125 – 0.375 0.310 – 0.560 0.500 – 0.750 0.310 – 0.560 0.500 – 0.750 0.700 – 0.950 73 T&B Conduit Fittings Stainless Steel Liquidtight Conduit Connectors The Strength of Steel — with Superior Corrosion-Resistance! A Until now, there’s been no ideal conduit fitting solution for use in heavily corrosive environments. Traditional metallic fittings corrode and require frequent replacement. Non-metallic fittings offer less strength, lower UV-resistance, and don’t stand up well in extreme temperatures. T&B Stainless Steel Liquidtight Conduit Connectors are constructed of 304 stainless steel to resist corrosion while offering high strength, high UV-resistance, and high endurance. Choose among a full range of fittings in straight, 45o, and 90o angled configurations for 3/8" to 2" conduit sizes. Look for the distinctive blue insulator and sealing ring for assurance of T&B quality. B A B C • Ideal for industrial MRO and OEM applications in food and beverage, pharmaceutical, petrochemical, waste water, salt water, and other corrosive environments • Connects metallic-cored liquidtight conduit to a box or enclosure A • 304 stainless steel body and gland-nut resists corrosion far better than other metallic fittings B • Stronger, more UV-resistant than nonmetallic fittings C • Available in straight, 45o, and 90o angled configurations to fit 3 conduit from /8" to 2" • UL® Listed Ratings: 3, 3R, 4, 4X 5262 Series Sealing Ring Gasket sold separately • 5262 Sealing Ring Gasket (sold separately) includes a stainless steel retaining ring to prevent elongation of the gasket and is made from Santoprene™ material, ensuring a superior seal Liquidtight Conduit Connectors Cat. Number Straight 5331SST * 5332SST 5333SST 5334SST 5335SST 5336SST 5337SST 45o Angled 5341SST * 5342SST 5343SST 5344SST 5345SST 5346SST 5347SST Dimensions B Size A /8" 1 /2" 3 /4" 1" 11/4" 11/2" 2" 1.360" 1.360" 1.388" 1.562" 1.720" 2.020" 2.335" /8" /2" /4" 1" 11/4" 11/2" 2" 1.84" 1.62" 2.32" 2.86" 3.33" 3.94" 4.73" 3 3 1 3 C Std. Pkg. Qty. UPC Number Cat. Number 1.02" 1.18" 1.37" 1.77" 2.12" 2.48" 3.04" — — — — — — — 25 25 25 5 20 5 2 78621097764 78621084482 78621074480 78621096334 78621097765 78621097766 78621097767 1.02" 1.18" 1.37" 1.77" 2.12" 2.48" 3.04" 1.43" 2.04" 1.93" 2.37" 2.80" 3.39" 4.23" 25 25 10 5 5 2 1 78621097775 78621097776 78621097777 78621097778 78621097779 78621097780 78621097781 Locknut not included * 3/8” conduit fitting has 3/8” hub 74 Size 90o Angled 5351SST * 3/8" 1 5352SST /2" 3 5353SST /4" 5354SST 1" 5355SST 11/4" 5356SST 11/2" 5357SST 2" Sealing Gasket 3 5261 /8" 1 5262 /2" 3 5263 /4" 5264 1" 5265 11/4" 5266 11/2" 5267 2" A Dimensions B C Std. Pkg. Qty. UPC Number 1.95" 2.12" 2.47" 2.98" 3.53" 4.16" 8.60" 1.02" 1.18" 1.37" 1.77" 2.12" 2.48" 3.04" 1.84" 2.07" 2.44" 2.90" 3.36" 3.88" 4.69" 25 25 10 5 5 2 1 78621097768 78621097769 78621097770 78621097771 78621097772 78621097773 78621097774 — — — — — — — — — — — — — — — — — — — — — 50 50 25 25 5 5 5 78621005261 78621005262 78621005263 78621005264 78621005265 78621005266 78621005267 T&B Conduit Fittings Flexible Cord and Cable Fittings The Ranger® Series — Nylon Cord Grip Fitting A T&B “RANGER” Exclusive Smaller shape: 30% smaller envelope Wide range: twice the cable range • Reduced size means fittings can be placed closer together. • Wider range means one fitting can cover twice the cable range of others. • Nonmetallic means corrosion resistance. Nonmetallic Liquidtight Strain Relief Fitting—Straight • Weather Stabilized Nylon • U.L. 94-V2 • Temperature Rating: -34ÞC to +105ÞC • Meets Coast Guard CG293 • New Reduced Size • Smaller Footprint Dimensions (in.) B Trade or Hub Size Throat Diam. Cord Range A 2920NM 2921NM 2922NM 1/2” 1/2” 1/2” 9/16 9/16 9/16 .125-.375 .310-.560 .500-.750 1-7/32 1-7/32 1-13/32 2-1/8 2-1/8 2-5/32 5/8 5/8 5/8 2930NM 2931NM 2932NM 3/4” 3/4” 3/4” 3/4 3/4 3/4 .125-.375 .310-.560 .500-.750 1-13/32 1-13/32 1-13/32 2-3/16 2-3/16 2-3/16 5/8 5/8 5/8 2940NM 2941NM 2942NM 1” 1” 1” 29/32 29/32 29/32 .310-.560 .500-.750 .700-.950 1-13/32 1-13/32 1-43/64 2-11/32 2-11/32 2-3/8 25/32 25/32 25/32 Cat. No. C Nonmetallic Liquidtight Strain Relief fitting— 90° Elbow Trade or Hub Size Throat Diam. Cord Range A Dimensions (in.) B C 4960NM 4961NM 1/2” 1/2” 9/16 9/16 .125-.375 .310-.560 1-7/32 1-7/32 1-1/4 1-1/4 5/8 5/8 4970NM 4971NM 4972NM 3/4” 3/4” 3/4” 3/4 3/4 3/4 .125-.375 .310-.560 .500-.750 1-13/32 1-13/32 1-13/32 1-3/8 1-3/8 1-3/8 5/8 5/8 5/8 Cat. No. 90° elbow, new reduced size, smaller footprint. • Weather Stabilized Nylon • U.L. 94-V2 • Temperature Rating: -34ÞC to +105ÞC • Meets Coast Guard CG293 75 T&B Conduit Fittings Flexible Cord and Cable Fittings Silver Grip™ — TCF™ Series Tray-Cord Fitting Large Tapered Bushing High-Performance Chuck Grip C Tray Cable Applications US One heck of a grip! Increased Safety for Hazardous Locations Introducing the Silver Grip™ Tray-Cord Fitting™ - the safe, yet cost-efficient choice for increased safety when terminating portable cord and tray cable in hazardous locations. Designed for use in Class I, Gas and Vapour environments, the Silver Grip™ Tray-Cord Fitting™ provides efficient strain relief for cables entering enclosures and raceways, and for cords used on portable equipment. • Corrosion-resistant, non-magnetic aluminum construction Portable Cord Applications • Tapered neoprene bushing and O-ring seal out moisture and dirt ingress • Chuck grip provides high mechanical pull-out performance. Exceeds applicable requirements. • Hand-tightens — no tools required • Now available in 316 stainless steel • 90°C temperature rating 76 T&B Conduit Fittings Maximum Opening ® TCF ® Series — Tray / Cord Fitting Gland Nut Ordering Information Chuck Grip Bushing Body O-Ring Hub Size NPT Catalogue Number Throat Diameter (in.) Minimum Cable Dia. (in.) Maximum Opening (in.) 1/2 1/2 1/2 1/2 1/2 3/4 3/4 3/4 3/4 3/4 1 1 1 1 1-1/4 1-1/4 1-1/4 1-1/2 1-1/2 1-1/2 2 2 2 2-1/2 3 3 3 TCF050-27AL TCF050-40AL TCF050-54AL TCF050-67AL TCF050-78AL TCF075-40AL TCF075-54AL TCF075-67AL TCF075-78AL TCF075-88AL TCF100-78AL TCF100-88AL TCF100-100AL TCF100-109AL TCF125-109AL TCF125-128AL TCF125-147AL TCF150-115AL TCF150-140AL TCF150-165AL TCF200-153AL TCF200-186AL TCF200-219AL TCF250-252AL TCF300-278AL TCF300-304AL TCF300-330AL 0.330 0.540 0.540 0.540* 0.540* 0.540 0.540 0.780 0.780 0.765* 0.980 0.980 0.980* 0.980 1.255 1.255* 1.255* 1.470 1.470 1.470* 1.896 1.896 2.062* 2.466* 2.780 3.050 3.068* 0.150 0.250 0.400 0.540 0.660 0.250 0.400 0.540 0.660 0.770 0.660 0.770 0.870 0.940 0.890 1.080 1.270 0.890 1.140 1.390 1.190 1.520 1.850 2.120 2.380 2.640 2.900 0.270 0.400 0.540 0.670 0.780 0.400 0.540 0.670 0.780 0.880 0.780 0.880 1.000 1.090 1.090 1.280 1.470 1.150 1.400 1.650 1.530 1.860 2.190 2.520 2.780 3.040 3.300 * When cord will not fit through body, strip cord jacket and trim fillers if required. Insert cable ensuring the outer jacket reaches the end of the bushing as shown. Tighten gland nut onto body. For stainless steel (316), replace AL for SS6 (up to 1“ only) Applications Tray Cable Complies with IEC requirements for Class I, Zone 2 locations when used with enclosures containing no ® arcing or sparking devices. For enclosures with arcing or sparking devices, TCF fittings must be used in combination with a certified Class I hazardous location sealing fitting. Portable Cord Complies with IEC requirements for Class I, Zone 1 locations when used with enclosures containing no ® arcing or sparking devices. For enclosures with arcing or sparking devices, TCF fittings must be used in combination with a certified Class I hazardous location sealing fitting. • File Number LR4484, Certificate Number 1388229 • CSA Class 4418-05 Fittings for Hazardous Locations Class I, Zone 1 Ex e II, IP66; Type 4/4X, (CSA) • CSAus Class 4418-85 Fittings for Hazardous Locations Class I, Zone 1, A Ex e II, IP66; Type 4/4X, (CSAus) N.B.: Tray cable is not suitable for use in Zone 1 locations. Portable cord can be used in Zone 1 applications only when installed on portable equipment. Utilisation • For use with unarmored cable Types suitable for use in Class I, Zone 1 (e.g.) Extra Hard Usage Cord) • Series TCF Cable Glands, when used with Tray Cables are suitable to be installed in Class I, Zone 2/Div. 2 Classified Hazardous Locations Areas according to CEC/NEC Wiring Method, or subject to Local Inspection Authority having jurisdiction. 77 T&B Conduit Fittings Flexible Cord and Cable Fittings Outside Tray — tray cable must be protected within conduit and flexible liquidtight metallic conduit. In this case, the connector bushing is simply replaced with a ground cone/sealing ring to terminate the assembly. Double face tape Sealing compound Ground cone B Sealing ring A C Gland nut Body The Canadian Electrical Code states that tray cable in hazardous locations can be used either within the cable tray, or outside the tray - provided there is additional protection. The TrayStar TM fitting was designed and engineered for either application and comes complete with the bushing, ground cone and sealing ring for different product applications. Ease of Installation Installation is quick and easy. When used on metallic liquidtight conduit, the fitting hub size correlates with that of the conduit trade size. (i.e. 1/2” fitting accomodates 1/2” conduit). The bushings, when utilized, are designed to accomodate a broad range of tray cable diameters. Either liquid or putty sealing compound can be used for a positive, gastight seal. The compound is ordered separately to allow for flexibility in making the correct selection for various types of installations. The sealing compounds cure in just a few hours. The TrayStar TM fitting also has disconnect capability: the cable can be disconnected and reconnected after being sealed. The unique hexagonal gland nut is conveniently grooved for screwdriver installation in extremely cramped areas. The gland nut is also clearly identified with the catalogue number and CSA approvals. It is also anodized an aquablue colour to identify it as a Hazardous Location, Tray Cable Fitting. Superior Construction TrayStar TM fittings have a low-profile compact design and are made of copper-free aluminum for long-lasting trouble-free service. Fittings are precision machined for superior fit and ease of installation. Putty insert Silver Grip® — Liquidtight Fittings for Tray Cable With conduit Cat. No. Inside Tray — Used with a neoprene bushing, TrayStar TM terminates tray cable within the tray itself. B Sealing compound Bushing Range Over Jacket (in.) min. max. Hub Size N.P.T. Conduit Trade Size (in.) Approx Compound Required* Putty / Liquid A SC65/SC4-KIT Throat Dia. cc (in.) B Overall (in.) C Dim. (in.) HLT050DATA 1/2 HLT050 1/2 HLT075 3/4 HLT100 1 HLT125 1-1/4 HLT150 1-1/2 HLT200 2 0.250 0.300 0.320 0.400 0.625 0.780 1.000 0.310 0.400 0.570 0.750 1.000 1.200 1.560 1/2 1/2 3/4 1 1-1/4 1-1/2 2 7 7 15 23 45 68 112 0.505 0.505 0.707 0.932 1.263 1.493 1.950 1.870 1.870 2.140 2.270 2.750 3.000 3.200 1.625 1.625 2.075 2.290 2.840 3.275 3.640 4-250TC 4-300TC 4-350TC 4-400TC 1.700 2.150 2.650 3.180 2.200 2.700 3.230 3.790 2-1/2 3 3-1/2 4 175 359 536 690 2.250 2.750 3.280 3.840 3.800 3.860 4.100 4.000 4.000 4.690 5.220 5.630 2-1/2 3 3-1/2 4 † Not UL Listed * Sealing compound not included with HLT-series. Order separately. A SC65 putty supplied with each TC-series fitting. SC4-Kit liquid sealing compound not approved for use with TC-series. C Retainer TC-series is suitable for use with tray cable only and cannot be used with conduit. Materials Aluminum: The above listed catalogue numbers relate to aluminum fittings. Steel: HLT-series is also available in steel. Add the suffix "S" to the catalogue number (example HLT050S). Certifications Type HLA. CSA Certified Class I, Division 2, Groups A, B, C and D; Class II, Division 2, Groups E, F and G; Class III, Division 2, Enclosure Type 4 SL (integral seal). CSA File 23086. Hub With bushing Sealing Compounds Cat. No. Description Volume (cubic centimeter) Liquid type sealing compound (includes pouch of sealing SC4-KIT compound with integral spout, fiber and damming material). SC4-KIT SC65 For more details, refer to the installation/Instruction sheet. 66 cc Use SC4-KIT liquid compound for shielded cables. Cat. No. Description SC65 Putty type sealing compound (cut-to-length stick) Volume (cubic centimeter) 34 cc Suitable for use on cables with a maximum of four conductors (including ground). We do not recommend SC65 for use with shielded cables. Quantity of compound required will vary according to cable conductor fill. U.L. File No. E-82038 CSA File No. LR-23086 Note - Thomas & Betts hazardous locations fittings with integral seals (STX, STEX, HLT and TC series) are UL and CSA certified only when used with SC4-KIT or SC65 sealing compounds. No other sealing compounds have been tested, certified or listed. 78 T&B Conduit Fittings Flexible Cord and Cable Fittings Nonmetallic Liquidtight Strain Relief Fitting—Straight • Weather Stabilized Nylon • U.L. 94-V2 • Temperature Rating: -34ÞC to +105ÞC • Meets Coast Guard CG293 Dimensions (in.) B Cat. No. Trade or Hub Size Throat Diam. Cord Range A 2671 2690 2672 2673* 2691* 2692* 2693 2694* 2674 2675 2696* 2676 2677 2678* 2699 2702 2703 2704 2705TB 2706 2707 2708 2709 2710* 3/8” 1/2” 1/2” 1/2” 1/2” 1/2” 3/4” 3/4” 3/4” 3/4” 3/4” 1” 1” 1” 1” 1-1/4” 1-1/4” 1-1/4” 1-1/2” 1-1/2” 1-1/2” 2” 2” 2” 0.33 0.33 0.55 0.55 0.54 0.54 0.55 0.55 0.79 0.79 0.76 0.98 0.98 0.98 0.98 1.25 1.25 1.25 1.47 1.47 1.47 1.89 1.89 1.89 .125-.275 .125-.275 .250-.400 .400-.560 .560-.690 .660-.780 .250-.400 .400-.560 .560-.690 .660-.780 .770-.895 .660-.780 .770-.895 .870-1.020 .890-1.090 .890-1.090 1.080-1.280 1.270-1.470 .890-1.150 1.140-1.400 1.390-1.650 1.190-1.530 1.520-1.860 1.850-2.190 2 2-4/16 2-19/32 2-19/32 3 3 2-11/16 2-11/16 3 3 3-3/16 3-5/16 3-5/10 3-5/10 3-3/10 3-5/16 4 4 4-3/16 4-5/16 4-5/16 5-3/32 4-29/32 4-29/32 29/32 29/32 19/32 19/32 1-9/10 1-9/16 1-9/32 1-9/32 1-9/16 1-9/16 1-7/8 1-7/8 1-7/8 1-7/8 2-19/32 1-7/8 2-19/32 2-19/32 2-31/32 2-31/32 2-31/32 3-1/2 3-1/2 3-1/2 C 15/32 19/32 19/32 19/32 19/32 19/32 5/8 5/8 5/8 5/8 5/8 25/32 25/32 25/32 25/32 25/32 13/16 13/16 13/16 13/16 13/16 27/32 27/32 27/32 * Remove sufficient outer covering of cable to permit conductors to pass thru fitting body. Nonmetallic Liquidtight Strain Relief Fitting— 90° Elbow 90° angle, standard size body. • Weather Stabilized Nylon • U.L. 94-V2 • Temperature Rating: -34ÞC to +105ÞC • Meets Coast Guard CG293 Cat. No. Trade or Hub Size Throat Diam. Cord Range A Dimensions (in.) B C 2680 2681 2682* 2683 2684 3/8” 1/2” 1/2” 3/4” 3/4” .33 .55 .55 .78 .78 .125-.275 .250-.400 .400-.560 .560-.690 .660-.780 .90 1.27 1.27 1.57 1.57 1.8 2.5 2.5 2.8 2.8 .460 .610 .610 .610 .610 2688 2685 2686 2687* 1” 1” 1” 1” .98 .98 .98 .98 .560-.690 .660-.780 .770-.895 .870-1.020 1.89 1.89 1.89 1.89 3.0 3.2 3.2 3.2 .770 .770 .770 .770 * Remove sufficient outer covering of cable to permit conductors to pass thru fitting body. 90° angle, standard size body. 79 T&B Conduit Fittings Portable Cord and Cable Fittings WMG-PC Series Wiremesh Grips for Portable Cord T&B Wiremesh grips are ordered separately and fit with your existing inventory of Ranger™ fittings and liquidtight strain relief fittings. There’s no need to duplicate inventory. Application • Provides high gripping strength for adequate cable support and strain relief without damage to the cable sheath • Compression of a tapered neoprene bushing, assures the watertight integrity of the fittings Wiremesh grips support the following Liquidtight Cord Fittings Series. 2920 Series Cord and Cable Type • S, SO, SV, ST, STD, SJ, SJO, SJT, SJTO, SVD Features • Prevents severe cord bends and pullouts • Used in aluminum and/or steel fittings 2920AL Series How to select proper wiremesh grip: Environment Classification • Ordinary Locations Range .187 – 3.220 3. Select Cat. No. of strain relief fitting e.g. 2520, 2920AL. 4. Match up O.D. with grip range and strain relief to determine Cat. No. of Wiremesh Grip (e.g. .200 + 2520 = WMP-PC1) 1. Determine O.D. of portable cord e.g. .200 2. Determine size of knockout or threaded hub e.g. 1/2" 2516 Series Material Wiremesh made of stainless steel. Retaining rings made of aluminum. Wiremesh Grips for Portable Cord Cat. No. Grip Range WMG-PC1 WMG-PC2 WMG-PC3 .187-.250 .250-.375 .375-.500 WMG-PC4 .500-.625 WMG-PC5 .625-.750 WMG-PC6 WMG-PC7 .187-.250 .250-.375 WMG-PC8 .375-.500 WMG-PC9 .750-.875 WMG-PC10 WMG-PC11 .875-1.000 .875-1.000 WMG-PC12 1.000-1.125 WMG-PC13 1.125-1.250 WMG-PC14 1.125-1.250 WMG-PC15 1.250-1.375 WMG-PC16* 1.375-1.500 WMG-PC17* 1.125-1.250 Straight Ranger™ Ranger™ Steel Aluminum 2920S 2920S 2921S 2922S 2932S 2941S 2922S 2932S 2941S 2930S 2930S 2920AL 2920AL 2921AL 2922AL 2932AL 2941AL 2922AL 2932AL 2941AL 2930AL 2930AL 2931S 2940S 2931AL 2940AL 2942S 2942AL Strain Relief Fitting 45° T&B Ranger™ T&B Steel Malleable Iron Steel 2520 2521 2522 2524 2534 2544 2525 2535 2545 2530 2531 2541 2532 2542 2536 2546 2547 2548 2558 2548 2558 2549 2559 2549 2559 2556 2563 2564 2256 2564 2557 2573 90° Ranger™ Ranger™ Malleable Iron Aluminum T&B Steel 4920 4920 4921 4922 4932 4941 4922 4932 4941 4930 4930 2200 2201 2202 2204 2209 2214 2205 2210 2215 2206 2207 4960 4960 4961 4962 4972 4981 4962 4972 4981 4970 4970 4960AL 4960AL 4961AL 4962AL 4972AL 4981AL 4962AL 4972AL 4981AL 4970AL 4970AL 2267 2268 2269 2250 2273 2255 2251 2274 2256 2252 2271 4931 4940 2208 2213 2211 2216 2217 2218 2220 2218 2220 2219 2221 4961 4980 4961AL 4980AL 4982 4982AL 2258 2258 2279 2279 2272 2254 2253 2275 2276 2257 2277 2257 2277 2258 2278 2219 2278 2222 2282 2283 2279 2283 2280 2284 4942 2221 – – 2222 — 2223 – 80 Cat. No. Grip Range WMG-PC18* 1.250-1.375 WMG-PC19* 1.375-1.500 WMG-PC20* 1.500-1.625 WMG-PC21* 1.625-1.750 WMG-PC22* 1.750-1.875 Strain Relief Fitting Straight 90° T&B T&B Steel Steel 2573 2565 2574 2565 2574 2575 2575 *Replacement Gland Nut Supplied With These Catalogue Numbers only 2284 2285 2285 2286 2286 T&B Conduit Fittings Portable Cord and Cable Fittings Nonmetallic Cable Glands — Low Profile for Tight Spots Sturdy Nylon 6 for strong, lightweight construction. Gray colour shown, also available in black. T&B Nylon Cable Glands have a sturdy cable sealing mechanism which results in superior strain relief. The compact size ensures quick and easy installation in cramped spaces. The nonmetallic construction provides excellent corrosion, chemical and impact resistance. The glands have long threads and locknuts are available. • Halogen free • Flame retardant material rated UL 94-V0 • Rated IP 68 5 BAR, suitable for NEMA 4 enclosures • UL Listed, CSA listed for certain ranges of cable • Working Temperatures: -30°C (-86°F) to +80°C (176°F) Continuous, 150°C (276°F) Intermittent • Meets VDE ratings Nonmetallic Cable Glands Cat no. Hub Size Colour Cable Range in. mm Length of Thread in. mm USE T&B Locknut cat. no. Unit pkg. Std. pkg. UPC code /8” /8” 1/2” 1/2” 3/4” 3/4” 1” 1” BLACK GREY BLACK GREY BLACK GREY BLACK GREY .197 - .394 .197 - .394 .394 - .551 .394 - .551 .512 - .709 .512 - .709 .709 - .984 .709 - .984 5-10 5-10 10-14 10-14 13-18 13-18 18-25 18-25 0.590 0.590 0.590 0.590 0.590 0.590 0.709 0.709 15 15 15 15 15 15 18 18 CI-1703PL* CI-1703PL* LN501 LN501 LN502 LN502 LN503 LN503 50 50 50 50 25 25 20 20 250 250 250 250 100 100 100 100 786210-95582 786210-07817 786210-95583 786210-07824 786210-95584 786210-07853 786210-95586 786210-14682 GREY GREY GREY GREY GREY .197 - .394 5-10 .236 - .473 6-12 .512 - .709 13-18 .709 - .984 18-25 .748 - 1.10 22-32 0.394 0.590 0.590 0.590 0.709 10 15 15 15 18 LN-ISO16-G LN-ISO20-G LN-ISO25-G LN-ISO32-G 50 50 25 20 250 250 250 250 786210-21170 786210-21173 786210-21174 786210-21175 GREY GREY GREY GREY GREY GREY GREY GREY .118 - .256 .157 - .315 .197 - .394 .236 - .473 .394 - .551 .512 - .709 .709 - .984 .867 - 1.26 0.315 0.315 0.315 0.354 0.394 0.433 0.433 0.512 8 8 8 9 10 11 11 13 LN-PG7-G LN-PG9-G LN-PG11-G LN-PG135-G LN-PG16-G LN-PG21-G LN-PG29-G LN-PG36-G 50 50 25 25 25 10 10 10 200 200 100 100 100 50 50 50 786210-21160 786210-21162 786210-21163 786210-21164 786210-21165 786210-21166 786210-21167 786210-21168 NPT Threads CC-NPT38-B CC-NPT38-G CC-NPT12-B CC-NPT12-G CC-NPT34-B CC-NPT34-G CC-NPT1-B CC-NPT1-G 3 3 ISO/Metric Threads CC-ISO-16-G CC-ISO-20-G CC-ISO-25-G CC-ISO-32-G CC-ISO-40-G M16 M20 M25 M32 M40 PG Threads CC-PG7-G 7 CC-PG9-G 9 CC-PG11-G 11 CC-PG135-G 13-1/2 CC-PG16-G 16 CC-PG21-G 21 CC-PG29-G 29 CC-PG36-G 36 * Not CSA Certified. 3-6.5 4-8 5-10 6-12 10-14 13-18 18-25 22-32 81 T&B Conduit Fittings Portable Cord and Cable Fittings Metric PG-to-N.P.T. Thread Adapters Cat. No. Supplied standard with all hoods and bases. Special sizes/hood combinations available. N.P.T. Thread (mating) Thread (at housing) 3/8” 1/2” 3/4” 1” 1-1/4” 1-1/4” 1-1/2” PG11 PG16 PG21 PG29 PG29 PG36 PG36 PG11-38 PG16-50 PG21-75 PG29-100 PG29-125 PG36-125 PG36-150 Metric Two-Screw Clamp Fittings Min. Max. Thread (at housing) .400” .250” .400” .455” .513” .800” 1.050” 1.500” .470” .325” .535” .625” .815” .175” .450” .800” PG11 PG11 PG13.5 PG16 PG21 PG291 PG361 PG421 Min. Max. Thread (at housing) .200” .325” .285” .285” .395” .780” .960” 1.630” .470” .340” .545” .625” .790” .060” .375” .650” PG11 PG11 PG13.5 PG16 PG21 PG291 PG361 PG421 Cable O.D. (in.) Cat. No. Style may vary depending on size. CC11-38 CC11-38P* CC135-50 CC16-50 CC21-75 CC29-100 CC36-125 CC42-150 * Plastic Metric Cord Grip Fittings Cable O.D. (in.) Cat. No. Standard European style — can be specified/ supplied with hoods and bases. CG11-38 CG11-38P* CG135-50 CG16-50 CG21-75 CG29-100 CG36-125 CG42-150 * Plastic Conduit Entry Blind Plug Thread (at housing) Cat. No. CXP722 CXP723 CXP724 CXP725 CXP726 CXP727 PG13.5 PG16 PG21 PG29 PG36 PG42 82 T&B Conduit Fittings Service Entrance Cable Fittings Suggested Specifications for Service Entrance Fittings • All service fittings shall be approved for the purpose by a nationally recognized testing laboratory, inspection agency, or product evaluation organization. Series 4175 Pipe Strap (EMT) Series 1275/1275AL Pipe Strap (Rigid Metal Conduit & I.M.C.) Series 1350/1350AL Pipe Spacer (Rigid Metal Conduit I.M.C. & EMT) • Where service raceway consists of a rigid metal conduit, intermediate metal conduit, electrical metallic tubing or where service entrance cable is used as service conductors a suitable raintight service head conforming to Federal Standard W-C-586 shall be provided. • Service raceway shall be securely fastened in place to the supporting surface at intervals as specified by the Code using suitable straps and spacers; straps and spacers shall be of malleable iron or steel construction, hot dipped galvanized or electro zinc plated conforming to Canadian Standards Association Standard C22.2 No. 18.4 and as manufactured by Thomas & Betts: series 1275 or 4175 straps and series 1350 spacers; aluminum straps or spacers such as series 1275AL and series 1350AL may be substituted when installed in environmental conditions that are more than normally corrosive. Series 3870 Bonding & Grounding Bushing—Insulated Series 106 Bonding Locknut 83 • For grounding and bonding of service raceway, end of raceway or the terminating fitting shall be equipped with bonding locknuts and insulated metallic grounding and bonding bushing as required. Bonding locknuts shall be of hardened steel or malleable iron construction, electro zinc plated, and provided with hardened bonding screws as manufactured by Thomas & Betts, series 106 bonding locknuts. Insulated metallic grounding and bonding bushing shall be of malleable iron/steel construction, electro zinc plated and assembled with an insulator listed or certified for 150°C/302°F service as manufactured by Thomas & Betts, series 3870. T&B Conduit Fittings Service Entrance Cable Fittings Suggested Specifications for Service Entrance Fittings—continued Series 2111 Service Entrance Cable Fitting Series 2116 Underground Feeder Cable Fitting Series 3302M Two Screw Fitting (Insulated) • Where service entrance cable is used as overhead service conductors and code requires use of a service head, entrance caps shall be installed; caps shall be cast metal type of suitable ferrous or non ferrous metal equipped with thermoset insulators and proper knockout openings; when installed with proper drip loop, caps must assure raintight conditions. • Terminating fittings for service entrance cable (Type SE or USE) or underground feeder and branch—circuit cable (Type UF) in locations where exposed to intermittent or constant moisture or in dry locations and subjected to mechanical strain shall be of watertight strain relief type as manufactured by Thomas & Betts, series 2111 or 2116; fittings shall be constructed of ferrous or non ferrous metal and equipped with taper-threaded hub, beveled moisture resistant/oil resistant synthetic rubber bushing. In dry locations, nylon insulated two screw type fittings of malleable iron/steel construction, electro zinc plated inside and outside including threads, such as series 3302M manufactured by Thomas & Betts may be substituted. Series 5262, 5302 Sealing Gasket Series 1341 Cable Strap 84 • Where service entrance cable is terminated into a threadless opening using hub type fittings, a gasket shall be provided between the outside of box or enclosure and fitting shoulder; gasket shall be of moisture resistant/ oil resistant synthetic rubber type adequately protected by and permanently retained to a metallic retainer as manufactured by Thomas & Betts, series 5262 or 5302. • Service entrance cable shall be adequately supported at intervals enumerated in code using cable straps conforming to requirements of CSA Standard C22.2 No.18.4; cable straps shall be of malleable iron/steel construction, hot dipped galvanized or electro zinc plated as manufactured by Thomas & Betts, series 1341. • At the point where the service cable enters the building, a suitable sill plate shall be provided; sill/wall plate shall be sealed to assure raintight conditions. T&B Conduit Fittings Service Entrance Cable Fittings Service Entrance Cable Fittings (C) (Type SE/Type Use) (D) (A) Application • To connect service entrance cables to a meter box or an enclosure. Standard Material/Finish Body Zinc Die Cast/As cast Gland Steel/Electro Zinc Plated & Chromate Coated Retaining Ring Stainless Steel/Passivated Bushing Neoprene/As molded (B) 2111 Series Range • Oval (Flat) Cable Size 0.260 x 0.500 thru 1.062 x 1.765 • Type USE Cable Size 3 #12 thru 3-4/0 AWG Conductors • Hub Size 1 ¼2” thru 2” NPT (taper pipe threads) Features • Neoprene bushing, resists oil and water; grips cable the full length of the bushing providing adequate strain relief without damaging outer jacket (A). • Taper-threaded body (B). • Stainless steel retaining ring protects cable jacket against abrasion; reduces installing torque effort (C). • Rugged ribbed steel gland construction (D). • Suitable for Type USE I75, USE I90 and USE B90 (CEC Table 19) Service Entrance Cable. Listing/Certification CEC Rule 6-300 (1) add (b) use underground service entrance with mechanical protection as per CEC Rule 12-012 Conformity U.L.514B, NEMA FB-1, Federal Standard H-28 (Threads), NFPA70-2009 (ANSI) CSA C22.2 No. 18.3 Underground Feeder Cable Fittings (C) (D) (A) (B) 2116 Series Application • To connect underground feeder cables to a box or an enclosure. Standard Material/Finish Body Zinc Die Cast/As cast Gland Steel/Electro Zinc Plated & Chromate Coated Retaining Ring Stainless Steel/ Passivated Bushing Neoprene/As molded Range • Oval (Flat) Cable Size 0.235 x 0.500 thru 0.260 x 0.740 • Hub Size 1/2” thru 1” NPT (tapered pipe threads) Features • Neoprene bushing resists oil and water; grips cable the full length of the bushing providing adequate strain relief without damaging outer jacket (A). • Taper-threaded body (B). • Stainless steel retaining ring protects cable jacket against abrasion; reduces installing torque effort (C). • Rugged ribbed steel gland construction (D). Listing/Certification CEC Rule 30-1004 (d) Wiring method, underground, where deviation has been allowed for permanent outdoor floodlighting installation. Conformity U.L.514B, NEMA FB-1, Federal Standard H-28 (Threads), NFPA70-2009 (ANSI) CSA C22.2 No. 18.3 85 T&B Conduit Fittings Service Entrance Cable Fittings Underground Liquidtight Feeder Cable Fittings Oil and water resistant neoprene bushing is especially designed for sealing around underground feeder cable. Stainless steel retaining ring provides a bearing surface for the glandnut and eliminates cable twist. Ribbed glandnut is strong and easily tightened with a wrench to make a connection of high strength. Cat. No. Hub Size Cable Opening 2116* 2237 2238 2239 1/2” 3/4” 3/4” 3/4” .235 x .500 .230 x .430 .235 x .465 .240 x .685 A B C 1-11/16 5/8 1 1-9/16 9/16 1-7/32 1-9/16 9/16 1-7/32 1-9/16 9/16 1-7/32 Dimensions (in.) D E min. max. min. max .060 .080 .050 .060 .235 .230 .235 .240 .350 .320 .340 .500 .500 .430 .465 .685 F G H 9/16 13/16 13/16 13/16 1-1/8 1-3/8 1-3/8 1-3/8 1-1/8 1-3/8 1-3/8 1-3/8 * Not CSA Certified. Watertight Fittings for Oval Cables A design with two tapers inside the body—a slow one and a fast one—permits the stocking of fewer fittings for varied cable sizes and allows maximum take-up. The tapered neoprene bushings are resistant to oil, sunlight, and water. Hex gland and body take the same wrench opening and a stainless steel slip ring prevents cable from twisting as gland ring is being tightened. Threads on the body are tapered for watersealing. Cat. No. Hub Size A 2111 1/2” 1-3/4 2232 2233 2234 Dimensions (in.) B C D Oval Cable Range E max. min. 1-1/4 5/8 1-3/8 1-3/8 .420 x .560 .380 x .520 3/4” 3/4” 3/4” 1-11/16 1-1/4 9/16 1-3/8 1-3/8 .385 x .600 .500 x .750 .555 x .800 .260 x .500 .375 x .625 .490 x .675 2432 2433 2434 1” 1” 1” 1-11/16 1-1/4 9/16 1-3/8 1-3/4 .385 x .600 .500 x .750 .555 x .800 .260 x .500 .375 x .625 .430 x .675 2438 2439 1” 1” 1-1/2 25/32 1-11/16 1-3/4 .565 x .855 .635 x .975 .440 x .730 .510 x .850 2442 2443 2446 1-1/4” 1-1/4” 1-1/4” .635 x .975 .640 x 1.050 .750 x 1.150 .510 x .850 .490 x .900 .565 x .965 2454 2447 1-1/2” 1-1/2” .840 x 1.275 .880 x 1.425 .655 x 1.090 .695 x 1.240 2448 2449 2450 2” 2” 2” .968 x 1.500 1.062 x 1.765 1.820 x 1.190 .790 x 1.390 .850 x 1.550 1.700 x 1.050 1-3/4 2-1/16 1-15/16 5/8 2-1/16 2-1/8 2-1/4 2-1/8 11/16 2-5/16 2-5/16 2-3/8 2-5/8 11/16 86 2-3/4 2-13/32 T&B Conduit Fittings Service Entrance Cable Fittings Cable Straps Dimensions (in.) Each strap takes a wide range of sizes because of the rocking action of the foot. Hole is for 1¼4” screw. Malleable iron, hot dipped galvanized construction. Cat. No. Wire Size A B 1341 1344 2-#10 3-#6 or 3-#8 5/8 5/8 1-1/8 1-15/16 1345* 1346 1347 3-#4 or 3-#2 3-1/0 3-4/0 13/16 3/4 3/4 1-59/64 2-7/16 2-25/32 * Steel, hot dipped galvanized. Nylon UF Cable Fittings for Corrosive Environments Cat. No. Hub Size max. min. A max. 2827 2828 2829 1/2” 3/4” 3/4” .550 x .280 .675 x .280 .775 x .280 .400 x .190 .525 x .190 .625 x .190 2.60 3.00 3.00 • Tapered threaded hub. • Liquidtight and dust-tight; hand tightens— no tools required. • Corrosive and weather resistant nylon for outdoor and indoor applications. 87 UF Cable Range Dimensions (in.) B C ± .060 ± .060 1.270 1.570 1.570 .600 .620 .620 T&B Conduit Fittings Liquidtight Flexible Metal Conduit Fittings Specifications — Liquidtight Flexible Metal Conduit Ref. CEC Rule 12-1300 Liquidtight flexible metal conduit is a raceway of circular cross section having an outer liquidtight nonmetallic, sunlight resistant jacket over a flexible metal core. Liquidtight flexible metal conduit is permitted to be used for exposed or concealed work, in dry, damp or wet locations indoors and outdoors. With the exception of Class I Division I locations, liquidtight flexible metal conduit is considered an acceptable wiring method in hazardous locations Class 1 Division 2 (CEC Rule J18-152(6). Liquidtight flexible metal conduit is not permitted where subjected to mechanical injury. The conduit is not permitted to be used underground or embedded in cinder fill or concrete. It cannot be used as a general purpose raceway. Use of liquidtight conduit is not permitted where any combination of ambient or conductor temperature will produce temperature in excess of that for which the jacket is rated or in locations where flexing at low temperature will injure jacket. Liquidtight flexible metal conduit is not permitted for conductors over 600 volts. Liquidtight flexible conduit is available in 3/8” through 6” trade size. Conduit is constructed with galvanized steel or aluminum core, regular or extra flex. Outer jacket is available for a variety of applications, e.g. oil resistant where exposed to cutting oils and for service temperature ranging from -50°C to 150°C. Listed and certified conduits are constructed of galvanized steel core and thermoplastic jacket rated for maximum service temperature of 60°C and suitable for exposure to mineral oils but not to gasoline and similar solvents. Conduit is required to be supported adequately, and bending is restricted to 360 degrees total. Please refer to the following for further details and complete information: 1. U.L. 360…Safety Standards for Liquidtight Flexible Steel Conduit 2. U.L. 514, Safety Standards for Outlet Boxes and Fittings 3. W-F-406…Federal Specification: Fittings for Cable, Power, Electrical and Conduit, Metal, Flexible 4. NEMA FB-1…Standards Publication: Fittings and Supports for Conduit and Cable Assemblies 5. EMP-1…JIC Electrical Standards for Mass Production Equipment 6. EGP-1…JIC Electrical Standards for General Purpose Machine Tools 7. CEC Section 12-1300…Wiring Methods (Liquidtight Metal Conduit) 8. CSA C22.2 No. 56…Safety Standard for Flexible Metallic Conduit and Liquidtight Flexible Metal Conduit Please Note The excerpts and other material herein, whether relating to the Canadian Electrical Code 2009 Part I, the Underwriters Laboratories, Inc. listing, to industry practice or otherwise, is not intended to provide all relevant information required for use and installation. Reference to original or primary source material and data is mandatory before any application or use is made of the product. 88 9. CSA C22.2 No. 18…Safety Standards for Outlet Boxes, Conduit Boxes and Fittings T&B Conduit Fittings Liquidtight Flexible Metal Conduit Fittings Suggested Specifications for Liquidtight Flexible Metal Conduit Fittings • Liquidtight Flexible Metal conduit used shall be of the type with galvanized steel core inside and outside and outer thermoplastic jacket suitable for the ambient environmental conditions. Jacket shall be positively locked to core to prevent sleeving. Where used as an equipment grounding conductor, the conduit shall conform to applicable standards U.L. 360/CSA C22.2 No. 56. Series 5331; Series 5231AL Liquidtight Flexible Metal Conduit Fittings Stainless Steel Retainer Resilient Sealing Material Locked in Steel Retainer Resilient Seal Series 5262 Sealing Gasket Series 3321 PVC Coated Liquidtight Flexible Metal Conduit Fittings Series 41 Liquidtight Union 5331GR Series External Bonding • Flexible conduit when installed shall have sufficient slack to avoid sharp flexing and straining due to vibration and thermal expansion/constriction. Conduit shall be installed in such a manner that liquids will tend to run off the surface instead of draining toward the fittings. • Where liquidtight flexible metal conduit terminates into a threaded or threadless opening, the conduit shall be assembled with approved liquidtight fittings. Fittings used shall be reusable type of malleable iron/steel construction, electro-zinc plated inside and outside, furnished with nylon insulated throat and taper threaded hub as manufactured by Thomas & Betts, series 5331. Approved fittings installed shall be: (1) Designed to prevent sleeving, assure plastic (raceway jacket) to plastic (gasket) seal. (2) Equipped with grounding device to assure ground continuity irrespective of raceway core construction. Grounding device if inserted into raceway and directly in contact with conductors shall have rolled over edges for sizes under 5 inches. At the point of flexing (i.e. where raceway leaves fitting) the thermoplastic raceway jacket shall not be permitted to be in direct contact with metal. 89 • Where liquidtight flexible metal conduit is terminated into a threadless opening using a threaded hub fitting such as Thomas & Betts series 5331, a suitable moisture resistant/oil resistant synthetic rubber gasket such as Thomas & Betts series 5262 shall be provided between the outside of box or enclosure and fitting shoulder. Gasket shall be adequately protected by and permanently bonded to a metallic retainer. • Where liquidtight flexible metallic raceway is installed in outdoor or indoor locations and is exposed to environmental conditions that are more than normally corrosive to exposed surfaces, PVC coated liquidtight flexible metal conduit fittings such as series 3321 manufactured by Thomas & Betts shall be used. Fittings shall be coated with a nominal thickness of .040 PVC and must meet the general requirements for liquidtight flexible metal conduit fittings indicated above. • Liquidtight fittings required to couple threaded end of a fitting or pipe where rotation of fitting or pipe is limited or restricted shall be reusable type of malleable iron/steel construction, electro-zinc plated inside /outside with taper threaded hub as manufactured by Thomas & Betts, series 41. Fittings shall be equipped with a moisture resistant/oil resistant synthetic rubber gasket. Metal to metal seal or metal to thermoplastic seal for this application shall be considered unacceptable. T&B Conduit Fittings Liquidtight Flexible Metal Conduit Fittings Specifications Application • Used where flexible metal raceway is installed in outdoor or indoor locations where exposed to continuous or intermittent moisture. 5331 Series 5231 AL Series 5361 Series 5271 Series 5341 Series… same as 5331, except 45° Fittings 5351 Series… same as 5331, except 90° Fittings • To positively bond conduit to box or enclosure. • 1/2” and 1-1/4” sizes Laboratory tested to carry ground fault current of up to 1000 amps RMS with duration of fault current 3 cycles. Features • Ability to install quickly with low torque effort. • Conforms with JIC requirements. •Ground cone design offers following advantages: (1) Compresses metallic convolutions; provides high quality ground contact with low impedance and high raceway holding power (A). (2) Single helical thread on ground cone is easy to install without cross threading; accepts variations in raceway diameters and convolution pitch (B). (3) Rolled over edge protects conductors (C). Sealing ring design has following exclusive features: (1) Grips and seals at leading and trailing edge—will not abrade raceway jacket (D). (2) Provided with grooves on inside diameter for anti-sleeving (E). (3) Shoulders on both ends for extra sealing (F). (4) Symmetrical shape assures foolproof assembly. • Can be disconnected and reused Predetermined Compression 5361 Series Chase Style • CEC Rule 12-1306 stipulates “a separate bonding conductor shall be installed in liquidtight flexible conduit in accordance with section 10”. • Watertight/oiltight installation at box or enclosure termination is assured by: (1) External taper thread hub on 5331 series and use of sealing gasket 5262 series (G). (2) Captive sealing ‘O’ ring on 5361 series (H). (3) Taper tapped hole on 5271series. • Suitable for use in Class I Division 2, Class II Division 1 and 2 and Class III Division 1 and 2 Hazardous Locations per CEC Section 18. Class I, Zone 2, CEC Rule 18-152 (6) Class I, Div. 2, CEC Rule J18-152 (6) Class II, Div. 1 CEC Rule 18-202 (4) (b) Class II, Div. 2, CEC Rule 18-252 (4) Class III, Div.1 CEC Rule 18-302 (4) Class III, Div. 2 CEC Rule 18-352 90 • Available with imperial, I.S.O. and PG threaded hub. Standard Material 5331-5361-5271 Series Body, Gland, Locknut and Ground Cones: All steel or malleable iron. Sealing Ring and Insulator: All thermoplastic rated min. -20ºc max. 105°C Sealing Gasket: Stainless Steel and Buna N 5231 AL Series All Copper-free Aluminum (non-insulated) Standard Finish 5331-5361-5271 Series Electro Zinc Plated and Chromate Coated 5231 AL Series Copper-free Aluminum Range • 5331 Series • 5341 Series • 5351 Series • 5361 Series • 5271 Series conduit • 5231 AL Series All hubs provided threads (NPT). 3/8” 3/8” 3/8” 3/8” 3/8” thru thru thru thru thru 6” conduit 4” conduit 4” conduit 4” conduit 1-1/4” 3/8” thru 4” conduit with taper pipe Conformity U.L. 514B CSA C22.2 No. 18.3 NEMA FB-1 NFPA 70-2008 (ANSI) JIC EGP1, JIC EMP1 Federal Specification W-F-406 Federal standard H-28 (Threads) T&B Conduit Fittings Liquidtight Flexible Metal Conduit Fittings High Temperature Flexible Metal Liquidtight Fittings T&B HT-Series Liquidtight Fittings are available straight, 45°, and 90°. Suggested Specification Where Liquidtight flexible metal fittings are required in high temperature environments up to 150°C: • Fitting’s body, gland, locknut and ground cone shall be constructed from steel or malleable iron, electro-zinc plated and chromate coated for corrosion protection. • Fitting’s sealing ring and throat insulator will be molded from high temperature nylon suitable for temperatures up to 150°C and a minimum UL flammability rating of UL94-V2. • The fitting shall be constructed to accept high temperature flexible metal liquidtight conduit rated to 150°C (works with our ATX Series conduit, p. 135). • The fitting shall have a plastic throat insulator to protect conductors. • The fitting shall have a steel ground cone to: - provide high quality ground contact -single helical thread for easy installation into conduit -rolled over edge to protect conductors • The fitting shall have a plastic sealing ring to: -grip and seal at leading and trailing edge (double bevel up to 2”) of conduit jacket -provide a watertight/oiltight seal • The fittings shall be capable to terminate the conduit in either a threaded or threadless opening. • For applications where termination into a threaded opening is required the fitting shall have external tapered NPT threads. • For applications where termination into a threadless opening is required use an acceptable sealing ring. • Fittings shall conform to UL 514B. • Accepted Manufacturers: Thomas & Betts — 5331-HT straight series, 5341-HT 45° series, 5351-HT 90° series; 5262 sealing ring series. B B A B A A C C C Straight Liquidtight Fittings Cat. No. 5331-HT 5332-HT 5333-HT 5334-HT 5335-HT 5336-HT 5337-HT 5338-HT 5339-HT 5340-HT Conduit Size (in.) 3/8 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 4 45° Liquidtight Fittings Dimensions (in.) A B C 1-5/32 1-1/2 1-3/8 1-9/16 1-21/32 1-5/8 1-7/8 2-1/16 2-9/32 2-1/2 2-22/32 2-11/16 3-1/4 3-1/16 3-3/4 4-1/8 4-1/2 4-1/4 5-1/2 4-1/2 9/16 9/16 9/16 3/4 13/16 13/16 7/8 1 1 1-1/8 Cat. No. 5341-HT 5342-HT 5343-HT 5344-HT 5345-HT 5346-HT 5347-HT 3/8 1/2 3/4 1 1-1/4 1-1/2 2 90° Liquidtight Fittings Dimensions (in.) A B C Conduit Size (in.) 1-5/32 1-9/16 1-3/8 1-7/8 1-21/32 2-1/8 1-7/8 2-1/4 2-9/32 2-3/4 2-22/32 2-3/8 3-1/4 3-7/8 9/16 9/16 9/16 3/4 13/16 13/16 7/8 Cat. No. 5351-HT 5352-HT 5353-HT 5354-HT 5355-HT 5356-HT 5357-HT Please note: There is no CSA and UL Standards applicable for High Temperature Fittings or Conduits. Therefore neither HT Fittings nor HT Conduit bear these Certifications/Listings. 91 Conduit Size (in.) 3/8 1/2 3/4 1 1-1/4 1-1/2 2 A Dimensions (in.) B C 1-5/32 1-3/8 1-3/8 1-9/16 1-21/32 1-3/4 1-7/8 2-3/16 2-9/32 2-3/4 2-22/322-15/16 3-1/4 3-7/16 9/16 9/16 9/16 3/4 13/16 13/16 7/8 T&B Conduit Fittings Liquidtight Flexible Metal Conduit Fittings Liquidtight Flexible Metal Conduit Fittings For Control and Power Cable Applications Cat. No. Hub Size Conduit Size A Dimensions (in.) B C 5229* 5330* 1/4” 3/8” 1/4 5/16 27/32 63/64 1-3/8 1-3/8 15/32 15/32 Dimensions (in.) B C * U.L. and CSA not applicable. Straight Fittings Steel, malleable iron, or aluminum tapered hub threads. With safe-edge ground thru 4” cone and double bevel sealing ring (through 2”). Insulated Cat. No. Aluminum‡ Noninsulated Conduit Size A 5331** 5332 5333 5334 5335 5336+ 5337+ 5338+ 5339+ 5340+ 5385*+ 5386*+ 5231AL 5232AL 5233AL 5234AL 5235AL 5236AL 5237AL 5238AL 5239AL 5240AL — — 5231 5232 5233 5234 5235 5236 5237 5238 5239 5240 5285* — 3/8 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 4 5 6 1-5/32 1-3/8 1-21/32 1-7/8 29/32 2-23/32 3-1/4 3-3/4 4-1/2 5-1/2 8-3/4 8-3/4 1-1/2 1-9/16 1-5/8 2-1/16 2-1/2 2-11/16 3-1/16 4-1/8 4-1/4 4-1/2 7 8-1/2 9/16 9/16 9/16 3/4 13/16 13/16 7/8 1 1 1-1/8 1-7/8 2 Suitable for hazardous locations use in CEC Rule 18-152 (6) Class I, Zone 2; CEC Rule J18-152 (6) Class I, Division 2; CEC Rule 18-202 (4) Class II, Division 1; CEC Rule 18-252 (4) Class II, Division 1 ** 3/8” Conduit Fitting has 1/2” hub. U.L. Listed liquidtight; and CSA Certified watertight. For Dura-Plate™ finish, add prefix 040- to Cat. No. Consult Customer Service for details. * Not CSA Certified. Steel + Malleable Iron 45° Angle Fittings* Cat. No. Malleable iron, tapered hub threads. With safeedge ground cone and double bevel sealing ring (through 2”). Dimensions (in.) B Insulated Noninsulated Conduit Size A 5341** 5342 5343 5344 5345 5346 5347 5348 5349 5350 5241 5242 5243 5244 5245 5246 5247 5248 5249 5250 3/8 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 4 1-5/32 1-3/8 1-21/32 1-7/8 29/32 2-23/32 3-1/4 3-3/4 4-1/2 5-1/2 1-9/16 1-7/8 2-1/8 2-1/4 2-3/4 3-3/8 3-7/8 4-1/4 4-1/4 4-5/8 C 9/16 9/16 9/16 3/4 1-3/16 1-3/16 7/8 1 1 1-1/8 * Suitable for hazardous locations use CEC Rule 18-152 (6) Class I, Zone 2; CEC Rule J18-152 (6) Class I, Division 2; CEC Rule 18-202 (4) Class II, Division 1; CEC Rule 18-252 (4) Class II, Division 1 ** 3/8” Conduit Fitting has 1/2” hub. U.L. Listed liquidtight; and CSA Certified watertight. For Dura-Plate™ finish, add prefix 040- to Cat. No. Consult Customer Service for details. For Wiremesh Grips refer to page 80. 92 T&B Conduit Fittings Liquidtight Flexible Metal Conduit Fittings 90° Angle Fittings Insulated 5351 5352 5353 5354 5355 5356 5357 5358 5359 5360 Dimensions (in.) B Cat. No. Noninsulated Aluminum Hub Size Conduit Size A 5251 5252 5253 5254 5255 5256 5257 5258 5259 5260 5251AL 5252AL 5253AL 5254AL 5255AL 5256AL 5257AL 5258AL* — — 1/2” 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 4” 3/8” 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 4” 1-5/32 1-3/8 1-21/32 1-7/8 29/32 2-23/32 3-1/4 3-3/4 4-1/2 5-1/2 1-3/8 1-9/16 1-3/4 2-3/16 2-3/4 2-15/16 3-7/16 8-7/8 10-1/4 12-5/8 C 9/16 9/16 9/16 3/4 13/16 13/16 7/8 1 1 1-1/8 Suitable for hazardous locations use in CEC Rule 18-152 (6) Class I, Zone 2; CEC Rule J18-152 (6) Class I, Division 2; CEC Rule 18-202 (4) Class II, Division 1; CEC Rule 18-252 (4) Class II, Division 2. U.L. Listed liquidtight; and CSA Certified watertight. * Not CSA Certified. Wiremesh Grips for Liquidtight Fittings Prevents severe conduit bends and pullout. Cat. No. Conduit Size Straight WMG-LT1 WMG-LT2 WMG-LT3 WMG-LT4 WMG-LT5 WMG-LT6 WMG-LT7 WMG-LT8 WMG-LT9 WMG-LT10 3/8” 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 4” 5331 5332 5333 5334 5335 5336 5337 5338 5339 5340 Liquidtight Fittings 45° 5341 5342 5343 5344 5345 5346 5347 5348 5349 5350 90° 90° Chase Chase Adapter 5351 5352 5353 5354 5355 5356 5357 5358 5359 5360 5361 5362 5363 5364 5365 5366 5367 5368 5369 5370 5371 5372 5373 5374 — — — — — — 5271 5272 5273 5274 5275 5276 5277 5278 5279 5282 Order wiremesh grip separately: no need to duplicate inventory. 93 T&B Conduit Fittings Liquidtight Flexible Metal Conduit Fittings Liquidtight Adapter To Connect Liquidtight to Threaded Rigid Conduit B A C Dimensions (in.) B Cat. No. Conduit Size (in.) A 5271 5272 5273 5274 5275 5276 3/8 1/2 3/4 1 1-1/4 1-1/2 1-5/32 1-3/8 1-21/32 1-7/8 2-9/32 2-3/4 1-9/16 1-11/16 1-3/4 2-1/8 2-1/2 2-11/16 C Std. Pkg. 1-3/8 1-3/8 1-3/8 1-3/8 1-3/8 1-3/8 50 50 50 25 25 10 With SAFE-EDGE™ ground cone and double bevel sealing ring (through 2”). Suitable for hazardous locations use in CEC Rule 18-152 (6) Class I, Zone 2; CEC Rule J18-152 (6) Class I, Division 2; CEC Rule 18-202 (4) Class II, Division 1; CEC Rule 18-252 (4) Class II, Division 2. Nylon Insulated CHASE® Fittings Steel or Malleable Iron B A C Dimensions (in.) B Cat. No. Conduit Size (in.) A 5361 5362 5363 5364 5365 5366 5367 5368 5369 5370 3/8 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 4 1-3/32 1-3/8 1-11/16 2-1/32 2-3/8 2-15/16 2-9/16 4-3/8 5-1/8 5-1/8 1-3/8 1-3/8 1-5/8 2-1/16 2-3/8 2-3/4 3 3-15/16 4-1/8 4-3/8 C Std. Pkg. 1/8 3/16 1/4 1/4 5/16 3/8 3/8 7/16 1/2 1/2 100 100 50 25 25 10 5 5 5 5 With SAFE-EDGE™ ground cone and double bevel sealing ring (through 2”). Note: UL Listed Liquidtight; and CSA Certified Watertight. Suitable for hazardous locations use in CEC Rule 18-156 (6) Class I, Zone 2; CEC Rule J18-156 (3) Class I, Division 2; CEC Rule 18-202 (4) Class II, Division 1; CEC Rule 18-252 (4) Class II, Division 2. 94 T&B Conduit Fittings Liquidtight Flexible Metal Conduit Fittings Specifications —External Bonding Application • Used where external bonding jumper is required around liquidtight flexible metal conduit. • To positively bond conduit to box or enclosure. Series 5331GR • Used where flexible raceway is installed in outdoor or indoor locations where exposed to continuous or intermittent moisture. Features • Designed with provision to install bonding jumper in several positions. • Designed to accept mechanical or compression lug. Series 5271GR • Ability to install quickly with low torque effort. (i) Compresses metallic convolutions; assures ground contact with low impedance and high raceway holding power (A). (ii) Single helical thread on ground cone is easy to install without cross threading; accepts variations in raceway diameters and convolution pitch (B). (iii) Rolled over edge protects conductors (C). • Sealing ring design has following exclusive features: (i) Grips and seals at leading and trailing edge—will not abrade raceway jacket (D). (ii) Provided with grooves on inside diameter for anti-sleeving (E). (iii) Shoulders on both ends for extra sealing (F). (iv) Symmetrical shape assures foolproof assembly. • Can be disconnected and reused. Sleeving Raceway Jacket pulls off—exposing core and affecting liquidtight termination. Feature (E) on sealing ring helps overcome this problem. • Watertight/oiltight installation at box or enclosure termination is assured by: 1. External taper thread hub on 5331GR series and use of sealing gasket 5262 series (G). 2. Taper tapped hole on 5271 series. • Suitable for use in Class I Division 2, Class II Division 1 & 2 and Class III Division 1 & 2 Hazardous Locations per CEC Section 18. 95 • Conforms with JIC requirements. • CEC Rule 12-1306 stipulates “a separate bonding conductor shall be installed in liquidtight flexible conduit in accordance with section 10”. • CEC Rule 10-618 (3) “The armour of flexible metal conduit and liquidtight flexible metal conduit shall not be considered as fulfilling the requirements of a bonding conductor for the purposes of this rule, and a separate bonding conductor shall be run within the conduit”. Standard Material Lugs: High conductivity copper (for copper conductor only). Body, Gland, Locknut & Ground Cones: All steel or malleable iron. Sealing Ring and Insulator: All thermoplastic Sealing Gasket: Stainless Steel & Buna N Strap: Steel Standard Finish All Electro Zinc Plated and Chromate Coated except lugs. Lugs: Bright Dipped Range • 5331GR Series (straight fittings with male hub): 3¼8” thru 6” conduit. • 5341GR Series (45°): 3¼8” thru 4” conduit • 5351GR Series (90°): 3¼8” thru 4” conduit. • 5271GR Series (straight fittings with female hub): 3¼8” thru 1-1/4” conduit. All hubs provided with taper pipe threads (NPT) Conformity U.L. 467 U.L. 514B CSA C22.2 No. 18.3 CSA C22.2 No. 41 NEMA FB-1 NFPA 70-2008 (ANSI) JIC EGP1 JIC EMP1 Federal Specification W-F-406 Federal Standard H-28 (threads) T&B Conduit Fittings Liquidtight Flexible Metal Conduit Fittings Straight Grounding Fittings* Cat. No. Steel Non-insulated Steel Insulated A C B Malleable iron, tapered hub threads. 5331GR** 5332GR 5333GR 5334GR 5335GR 5336GR 5337GR 5338GR 5339GR 5340GR 5385GR 5386GR 5231GR 5232GR 5233GR 5234GR 5235GR 5236GR 5237GR 5238GR 5239GR 5240GR 5285GR — Aluminum Non-insulated Conduit Size 5231ALGR* 5232ALGR* 5233ALGR* 5234ALGR* 3/8” 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 4” 5” 6” Ground Wire D Dimensions (in.) A B C 1-5/32 1-1/2 1-3/8 1-9/16 1-21/32 1-5/8 1-7/8 2-1/16 2-1/4 2-1/2 3-1/4 2-11/16 3-13/16 3-1/16 4-7/16 4-1/8 5-3/16 4-1/4 6-1/8 4-1/2 8-9/16 7 8-17/32 8-1/2 9/16 9/16 9/16 3/4 13/16 13/16 7/8 1 1 1-1/8 1-7/8 2 14-8 14-8 14-4 14-4 8-1/0 4-2/0 4-2/0 2-4/0 2-4/0 2-4/0 2-4/0 2-4/0 45° Angle Grounding Fittings Ground Wire Max. over Ribs Malleable iron, tapered hub threads. Cat. No. Insulated Non-insulated Conduit Size 5341GR** 5342GR 5343GR 5344GR 5345GR 5346GR 5347GR 5348GR 5349GR 5350GR 5241GR** 5242GR 5243GR 5244GR 5245GR 5246GR 5247GR 5248GR 5249GR 5250GR 3/8” 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 4” Dimensions (in.) A B C 1-5/32 1-9/16 1-3/8 1-7/8 1-21/32 2-1/8 1-7/8 2-1/4 2-1/4 2-3/4 3-1/4 3-3/8 3-13/16 3-7/8 4-7/16 4-1/4 5-3/16 4-1/4 6-1/8 4-5/8 9/16 9/16 9/16 3/4 13/16 13/16 7/8 1 1 1-1/8 Ground Wire D 14-8 14-8 14-4 14-4 8-1/0 4-2/0 4-2/0 2-4/0 2-4/0 2-4/0 90° Angle Grounding Fittings Ground Wire Max. over Ribs Malleable iron tapered hub threads. Steel Insulated Cat. No. Steel Non-insulated 5351GR** 5352GR 5353GR 5354GR 5355GR 5356GR 5357GR 5358GR 5359GR 5360GR 5251GR** 5252GR 5253GR 5254GR 5255GR 5256GR 5257GR 5258GR 5259GR 5260GR Aluminum Non-insulated Conduit Size Dimensions (in.) A B C Ground Wire D 5251ALGR* 5252ALGR* 5253ALGR* 5254ALGR* 3/8” 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 4” 1-5/32 1-1/4 9/16 1-3/8 1-7/16 9/16 1-21/321-13/16 9/16 1-7/8 2-1/16 3/4 2-1/4 2-1/2 13/16 3-1/4 2-15/16 13/16 3-13/16 3-7/16 7/8 4-7/16 8-7/8 1 5-3/16 10-1/4 1 6-1/8 12-5/8 1-1/8 14-8 14-8 14-4 14-4 8-1/0 4-2/0 4-2/0 2-4/0 2-4/0 2-4/0 * Not CSA Certified ** 3/8” conduit fittings have 1/2” trade size hub. With safe-edge ground cone (through 4”) and double bevel sealing ring (through 2”). Suitable for hazardous locations use in Class I, Division 2; Class II, Division 1 and 2; Class III, Division 1 and 2, where general purpose equipment is specifically permitted per CEC Rule 18-152 (6) Class I, Zone 2; CEC Rule J18-156 (3) Class I, Division 2; CEC Rule 18-202 (4) Class II, Division. 1; CEC Rule 18-252 (4) Class II, Division 2. Note: 3/8”-1” fittings include Revolver ™ grounding device. For sizes 1-1/4” and up, fittings are supplied with a copper mechanical lug. 96 T&B Conduit Fittings Liquidtight Flexible Metal Conduit Fittings External Grounding Strap Swing Radius Bolt Cat. No. Conduit Size A Swing Radius B Bolt Size GR1W GR2W GR3W GR4W GR5W 3/8” 1/2” 3/4” 1” 1-1/4” 1 1-1/16 1-3/8 1-1/2 1-7/8 10-24 10-24 1/4-20 1/4-20 5/16-18 For retrofit applications. Includes strap, nut and bolt. Bolt Size Liquidtight to Rigid External Ground Adaptor C Lug Range Cat. No. Conduit Size A Overall Length B Bolt Size C Lug Range 5271GR* 5272GR 5273GR 5274GR 5275GR 5276GR 3/8” 1/2” 3/4” 1” 1-1/4” 1-1/4” 1-15/32 1-3/8 1-21/32 1-7/8 2-1/4 2-29/32 10-24 10-24 1/4-20 1/4-20 5/16-18 3/8-16 14-8 14-8 14-4 14-4 8-1/0 3/8-16 * 3/8” conduit fittings have 1¼2” trade size hub. For Dura-Plate™ finish add prefix 040- to Cat. No. Consult Customer Service for details. A Revolver® Grounding Device Conduit Size Cat. No. 38GR-TB 12GR-TB 34GR-TB 1GR-TB 3/8” 1/2” 3/4” 1” The grounding device is a combination of a set screw and a grounding lug that can be used to retrofit any existing liquidtight fithing to an externally grounded version. 97 T&B Conduit Fittings Liquidtight Flexible Metal Conduit Fittings Specifications — PVC Coated Application • Used where liquidtight flexible metal conduit is installed in outdoor or indoor locations where exposed to environmental conditions that are more than normally corrosive to exposed surfaces. 3321 Series* • To positively bond conduit to box or enclosure. *3361 Series...same as 3321, except 90° 3341 Series...same as 3321, except 45° Features • PVC coated to protect fitting from extremely corrosive surroundings without affecting integrity of electrical grounding path (A). • Provided with overlapping sleeve for additional seal (B). • Ability to install quickly with low torque effort. Gland (F) Leading Edge Sealing Ring Raceway Core Convolutions (C) (E) (A) (B) (G) Ground Cone (A) (D) (B) (F) Trailing Edge Body (I) Taper Threaded Hub Sealing Gasket Locknut (H) 3321 Series • Ground cone design offers following advantages: (1) Compresses metallic convolutions; provides high quality ground contact with low impedance and high raceway holding power (C). (2) Single helical thread on ground cone is easy to install without cross threading; accepts variations in raceway diameters and convolution pitch (D). (3) Rolled over edge protects conductors (E). • Sealing ring design has following exclusive features: (1) Grips and seals at leading and trailing edge—will not abrade raceway jacket (F). (2) Provided with grooves on inside diameter for anti-sleeving (G). (3) Shoulders on both ends for extra sealing. (4) Symmetrical shape assures foolproof assembly. • Hardened steel or malleable iron locknut (H). • Can be disconnected and reused. 98 • Watertight/oiltight installation at box or enclosure termination is provided by external taper thread hub and sealing gasket (I). • Suitable for use in Class I Division 2, Class II Division 1, 2 and Class III Division 1, 2 Hazardous Locations per CEC Rule 18-152 (6) Class I, Zone 2; CEC Rule J18-156 (3) Class I, Div. 2; CEC Rule 18-202 (4) Class II, Div. 1; CEC Rule 18-252 (4) Class II, Div. 2. • Conforms with JIC requirements. Standard Material Body, Gland, Locknut and Ground Cones: All steel or malleable iron. Sealing Ring and Insulator: All thermoplastic Sealing Gasket, Retainer: Stainless Steel Resilient Seal: Buna N Coating: PVC Standard Finish Outside of body and gland: PVC Coated .040 min. Thickness Inside of body and gland: Electro Zinc Plated and Chromate Coated Locknut, Sealing Gasket, and Retainer: Electro Zinc Plated and Chromate Coated Range • 3321, 3361 and 3341 Series 3 ¼8” thru 4” conduit. All hubs provided with taper pipe threads (NPT). Conformity U.L. 514B CSA C22.2 No. 18.3 NEMA FB-1 NFPA 70-2008 (ANSI) JIC EGP1 JIC EMP1 Federal Specification W-F-406 Federal Standard H-28 (THREADS) T&B Conduit Fittings Liquidtight Flexible Metal Conduit Fittings Corrosion Resistant PVC Jacketed Liquidtight Fittings Cat. No. Conduit Size A Dimensions (in.) B C 3/8 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 4 1-15/32 1-5/8 1-15/16 2-1/4 2-11/16 3-1/8 3-5/8 4-3/8 5-3/16 6-7/16 2-5/16 2-1/2 2-25/32 3-15/32 4-1/4 4-11/16 5-5/16 6-3/8 6-1/2 6-3/4 9/16 9/16 9/16 3/4 13/16 13/16 7/8 1 1 1-1/8 3/8 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 4 1-15/32 1-5/8 1-15/16 2-1/4 2-11/16 3-1/8 3-5/8 4-3/8 5-3/16 6-7/16 2-3/16 2-1/2 2-29/32 3-19/32 4-1/2 4-15/16 5-11/16 11-1/8 12-1/2 14-7/8 9/16 9/16 9/16 3/4 13/16 13/16 7/8 1 1 1-1/8 3/8 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 4 1-15/32 1-5/8 1-15/16 2-1/4 2-11/16 3-1/8 3-5/8 4-3/8 5-3/16 6-7/16 1-1/8 1-1/4 1-7/16 1-13/16 2-1/16 2-11/16 3-3/16 3-13/16 4-9/16 5-3/4 9/16 9/16 9/16 3/4 13/16 13/16 7/8 1 1 1-1/8 Straight PVC Coated Straight PVC Coated Nylon Insulated Steel or Malleable Iron NPT hub threads 3321 3322 3323 3324 3325 3326 3327 3328-TB 3329 3331 90° PVC Coated 90° PVC Coated Nylon Insulated NPT hub threads 3361 3362 3363 3364 3365 3366 3367 3368 3369 3371 45° PVC Coated 45° PVC Coated Nylon Insulated NPT hub threads 3341 3342 3343 3344-TB 3345 3346 3347 3348-TB 3349 3352 Complies with J.I.C. standards and Federal Specs W-F-406B, W-F-408B Suitable for hazardous locations use in Class I, Div. 2; Class II, Div. 1 and 2; Class III, Div. 1 and 2, where general purpose equipment is specifically permitted per CEC Rule 18-156 (6) Class I, Zone 2; CEC Rule J18-152 (3) Class I, Div. 2; CEC Rule 18-202 (4) Class II, Div. 1; CEC Rule 18-252 (4) Class II, Div. 2. 99 T&B Conduit Fittings Liquidtight Flexible Metal Conduit Fittings Specifications —Liquidtight Union for Threaded Hub Application • To couple threaded end of a fitting or a pipe to a tapped opening in a box or enclosure where rotation of fitting or pipe is limited or restricted. Features • Provides high quality bond between fitting or pipe to the union. 41 Series (B) Controlled Deformation of Resilient Seal (E) (C) (D) Gland Resilient Seal (A) • Provided with resilient seal (A). • Resilient seal subjected to controlled deformation; positive seal and reusability are assured (B). • Unique design centralizes throat openings of threaded hub and union (C). • Permits orientation of fitting in any predetermined direction for a safe, functional and neat assembly. • Provided with taper-threaded hub for liquidtight assembly (D). • Straight pipe threads on gland accept a straight-or taper-threaded hub on fitting or pipe to be coupled (E). • Suitable for hazardous location use per CEC Rule J18-106 Class I, Div. 1; CEC Rule 18-202 Class II, Div. 1; CEC Rule 18-252 Class II, Div. 2; CEC Rule 18-302 Class III, Div. 1; CEC Rule 18-352 Class III, Div. 2; Standard Material/Finish Gland Steel/Electro Zinc Chromate Coated Body Steel/Electro Zinc Chromate Coated ‘O’ Ring Buna N/As Molded Range • Hub (External Thread) 1/2” and 3/4” NPT • Gland (Internal Threads) 1/2” and 3/4” NPS Conformity U.L. 514B CSA C22.2 No. 18.3 NEMA FB-1 ANSI C80.4 NFPA 70-2008 (ANSI) Federal Specification W-F-408 Federal Specification W-F-406 Federal Standard H-28 (Threads) Body Liquidtight Union for Threaded Hub Dimensions (in.) Cat. No. Conduit Size A B 41TB 42TB 1/2” 3/4” 1-29/64 1-15/16 1 1-1/4 Steel, zinc plated and chromated. Ideal for angle fittings where swing clearance is not available. 100 T&B Conduit Fittings Liquidtight Flexible Nonmetallic Conduit Fittings Specifications — Type A Conduit Fittings Series 6302 Liquidtight Flexible Nonmetallic Conduit Fittings Application • To provide a liquidtight, dustight connection between flexible, nonmetallic conduit and a box or an enclosure. Standard Body Gland ‘O’ Ring Locknut Features • Serrated design provides high mechanical pullout strength (A). Standard Finish Body, Gland & ‘O’ Ring As Molded Locknut Electro Zinc • Unique component parts (body/gland) design insures positive seal between conduit and fitting (B). • Tapered thread hub and sealing ‘O’ ring provide a liquidtight/dust tight seal to a box or an enclosure (C). Material Thermoplastic Thermoplastic Neoprene Steel (Case Hardened) Range • Conduit Size • Hub Size N.P.T. 1/2” thru 1-1/4” 1/2” thru 1-1/4” • High strength, chemical resistant, non-burning, non-dripping thermoplastic construction. • Smooth insulated body throughout for maximum dielectric strength. Series 6322 Liquidtight Flexible Nonmetallic Conduit Fittings • Captive ‘O’ ring and reduced number of parts save installation time (D). Suggested Specifications for Type A Conduit and Fittings (A) Left-Handed Threads Gland Body Sealing ‘O’ Ring Locknut Liquidtight Flexible Nonmetallic Conduit (A & B) Gland Body Sealing ‘O’ Ring (D) Captive Sealing ‘O’ Ring • Type A Liquidtight Flexible Nonmetallic Conduit shall be seamless type adequately reinforced with one or more layers of flexible braided reinforcing cords. Conduit jacket shall be of non-kinking oil resistant/water resis-tant flame retardant material suitable for ambient environmental conditions. Thomas & Betts. Fittings shall be of malleable iron/steel/thermoplastic construction with taper-threaded hub and: • Where Type A Flexible Nonmetallic Conduit terminates into a threaded or threadless opening, the conduit shall be cut square, deburred, installed with sufficient slack to reduce effects of vibration and assembled with approved fittings such as series 6302 or 3720 manufactured by (2) Thermoplastic fittings shall be of high impact chemical resistant, non-burning, non-dripping thermoplastic. (C) Taper Threaded Hub 101 (1) Ferrous metallic fittings shall be electro-zinc plated inside outside and equipped with a nylon insulated throat. (3) Fittings shall be provided with a captive, moisture resistant/oil resistant synthetic rubber gasket. T&B Conduit Fittings Liquidtight Flexible Nonmetallic Conduit Fittings Thermoplastic Fittings for Liquidtight Flexible Nonmetallic Conduit Type A Straight Fitting A Dimensions (in.) B C Cross Corners Cat. No. Conduit Size Straight Fitting 6302 6303 6304 6305 1/2” 3/4” 1” 1-1/4” .60 .61 .77 .79 1.68 1.85 1.89 2.30 1.48 1.76 2.10 2.67 1/2” 3/4” 1” 1-1/4” .60 .61 .77 .79 1.56 1.74 1.78 2.13 1.48 1.76 2.10 2.67 90° Angle Fitting 6322 6323 6324 6325 Corrosion Resistant Applications Meets Coast Guard CG293 *Use with our LNM-P Conduit on p. 146 90° Angle Fitting Designed especially for the Type A, all-plastic raceways now in use for dynamic machine tool applications. Fittings are constructed of a high-strength, chemically resistant thermoplastic tougher than the raceway itself. Neoprene sealing ring is furnished with fitting providing a liquidtight seal for knockout applications. Liquidtight Flexible Nonmetallic Conduit Type A • Nylon insulated throat. • T&B Sealing Ring to seal knockouts. • Steel or malleable iron. • U.L. Listed. • NPT hub threads to seal in female threads. • High mechanical pull-out strength. • Provides positive seal against water, oil and dust. Dimensions (in.) Cat. No. Conduit Size Hub Thread A B 3720-TB* 3721-TB 3722-TB 3723 3724-TB 3725 3726 3/8 1/2 3/4 1 1-1/4 1-1/2 2 1/2—14 NPT 1/2—14 NPT 3/4—14 NPT 1—11-1/2 NPT 1-1/4—11-1/2 NPT 1-1/2—11-1/2 NPT 2—11-1/2 NPT 1-5/32 1-3/8 1-5/8 1-7/8 2-3/8 2-3/4 3-17/32 2 2-1/8 2-1/4 2-1/2 2 3-3/8 3-5/8 * Not U.L. Listed For Dura-Plate™ Finish, add prefix 040- to Cat. No. Consult Customer Service for details. 102 T&B Conduit Fittings Liquidtight Flexible Metal Conduit Fittings 45° Metallic Fittings Dimensions (in.) Cat. No. Conduit Size Hub Thread A B 3730-TB* 3731-TB 3732 3733-TB 3734-TB 3735-TB 3736 3/8 1/2 3/4 1 1-1/4 1-1/2 2 1/2—14 NPT 1/2—14 NPT 3/4—14 NPT 1—11-1/2 NPT 1-1/4—11-1/2 NPT 1-1/2—11-1/2 NPT 2—11-1/2 NPT 1-5/32 1-3/8 1-5/8 1-7/8 2-3/8 2-3/4 3-17/32 2-13/32 2-9/16 3 3-1/2 4-1/8 4-7/8 5-1/2 * Not U.L. Listed Available with Dura-Plate™ Finish. Consult Customer Service for details. 90° Metallic Fittings Dimensions (in.) Cat. No. Conduit Size Hub Thread A B 3740* 3741 3742 3743-TB 3744-TB 3745 3746-TB 3/8 1/2 3/4 1 1-1/4 1-1/2 2 1/2—14 NPT 1/2—14 NPT 3/4—14 NPT 1—11-1/2 NPT 1-1/4—11-1/2 NPT 1-1/2—11-1/2 NPT 2—11-1/2 NPT 1-5/32 1-3/8 1-5/8 1-7/8 2-3/8 2-3/4 2-17/32 1-5/8 1-3/4 2-1/4 2-9/16 3-1/4 3-1/2 4-1/8 * Not U.L. Listed Available with Dura-Plate™ Finish. Consult Customer Service for details.. Liquidtight K.O. Plugs A NEMA 3R, 4, 6 & 13 Temperature range — -30°C to 105°C. Cat. No. Size 5710 5711 5712 5713 5714 5715 5716 5717 5718 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 4” U.L. Listed liquidtight CSA not applicable Meets Coast Guard Regulation CG293 103 Dimensions (in.) A 1-9/32” 1-1/2” 1-27/32” 27/32” 2-1/2” 3-3/32” 3-21/32” 4-19/64” 5-19/64” T&B Conduit Fittings Liquidtight Flexible Metal Conduit Fittings Specifications — Liquidtight Sealing Gaskets Application • When used with an externally threaded fitting provides a tight seal against oil, fumes or moisture at the knockout opening. 5262 Series Standard Material Retainer Sealing Material Stainless Steel Buna N Range • 1/2” thru 4” Hub Size Features • Locks resilient sealing material in steel. • Steel retainer protects seal from extruding out under torque and limits compression to an optimum predetermined value; provides high quality seal. • Resilient material flows and seals rough surfaces. Stainless Steel Retainer Resilient Sealing Material Locked in Steel Retainer Resilient Seal Sealing Ring with Stainless Steel Retainer B Thickness NEMA 3R, 4, 6 & 13 For use with T&B Fittings. Sealing material resists oil, coolants, and hydraulic fluids as well as water. Dimensions (in.) Cat. No. Conduit Size A B 5299** 5261** 5262 5263 5264 5265 5266 5267 5268 5269 5270 1/4” 3/8” 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 4” .80 .95 1.16 1.49 1.75 2.15 2.42 2.92 3.44 4.08 5.29 .11 .11 .18 .19 .19 .22 .23 .23 .23 .23 .31 ** U.L. not applicable 104 T&B Conduit Fittings Liquidtight Flexible Metal Conduit Fittings Liquidtight Flexible Metal/MS Fittings T&B Liquidtight flexible metal and Liquidtight flexible nonmetallic fittings with internal threads to accept AN-MS fitting shells. Material: Steel Cat. No. Trade Size LTA03810 LTA03814 LTA05014 LTA05016 LTA05018 LTA07516 LTA07518 LTA07520 LTA10020 LTA10024 3/8 3/8 1/2 1/2 1/2 3/4 3/4 3/4 1 1 Internal Thread AN-MS Conn. Shell Size Thread Size 10SL, 12, 12S 14, 14S 14, 14S 16, 16S 18 16, 16S 18 20, 22 20, 22 25, 28 Dimensions (in.) A B 5/8—24 UNEF-2B 3/4—20 UNEF-2B 3/4—20 UNEF-2B 7/8—20 UNEF-2B 1—20 UNEF-2B 7/8—20 UNEF-2B 1—20 UNEF-2B 1-3/16 —18 UNEF-2B 1-3/16 —18 UNEF-2B 1-7/16 —18 UNEF-2B 1-5/32 1-5/32 1-5/16 1-5/16 1-5/16 1-7/16 1-7/16 1-7/16 1-3/4 1-3/4 1 1 1-1/4 1-1/4 1-1/4 1-1/2 1-1/2 1-1/2 1-23/32 1-23/32 PG Metric Thread Liquidtight Fittings* Cat. No. Flexible Conduit Size Metric PG Thread A Dimensions (mm) B C 9 9 11 13.5 16 21 29 36 42 48 36 36 40 40 41 43 56 67 72 81 21 26 29 29 35 42 47 58 69 83 12 12 14 14 14 14 19 21 21 21 11 13.5 16 21 29 36 42 48 27 27 30 34 44 51 60 73 29 29 35 42 47 58 69 76 14 14 14 14 19 19 21 24 11 13.5 16 21 29 36 42 48 37 37 40 44 56 70 75 87 29 29 35 42 47 58 69 83 14 14 14 14 21 21 21 24 Nylon insulated straight fittings 7330** 7360** 7361* 7362* 7363* 7364* 7365 7366 7367 7368 1/4” 5/16” 3/8” 3/8” 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” Nylon insulated 45° angle fittings 7341 7342 7343 7344-TB 7345 7346 7347 7348-TB 3/8” 3/8” 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” Nylon insulated 90° angle fittings Fittings for Liquidtight flexible metal conduit with metric threads of PG Form (DIN 40430). 7351 7352 7353 7354 7355 7356 7357 7358 3/8” 3/8” 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” U.L. Listed liquidtight. *CSA Certified dusttight and watertight. **U.L. not applicable and not CSA Certified. 105 T&B Conduit Fittings Liquidtight Flexible Metal Conduit Fittings ISO Metric Thread Liquidtight Fittings* Cat. No. Flexible Conduit Size Metric ISO Thread A Dimensions (mm) B C 16 20 16 16 20 20 25 32 36 36 36 40 40 42 45 54 21 21 26 29 29 35 42 47 12 12 12 16 16 16 16 23 16 20 20 25 32 27 27 27 31 34 29 29 35 42 47 16 16 16 16 23 16 20 20 25 32 35 35 39 43 48 29 29 35 42 47 16 16 16 16 23 Nylon insulated straight fittings 9330 9331 9306 9360 9361 9362 9363 9364 1/4” 1/4” 5/16” 3/8” 3/8” 1/2” 3/4” 1” Nylon insulated 45° angle fittings 9340 9341 9342 9343TB 9344 3/8” 3/8” 1/2” 3/4” 1” Nylon insulated 90° angle fittings 9350 9351 9352TB 9353TB 9354TB 3/8” 3/8” 1/2” 3/4” 1” U.L. Listed Liquidtight. Fittings for Liquidtight flexible metal conduit with metric threads of ISO Form (BS-4568-SA BS 162). NPT/MS Fitting Adaptors A Cat. No. Fig. 1 B B Fig. 2 N.P.T. Thread AN-MS Fitting Shell Size Thread Size A 1/2” 1/2” 1/2” 3/4” 3/4” 3/4” 1 1 1 1 14, 14S 16, 16S 18 16, 16S 18 20, 22 20, 22 24, 28 32 36 3/4—20 UNEF-2B 7/8—20 UNEF-2B 1—20 UNEF-2B 7/8—20 UNEF-2B 1—20 UNEF-2B 1-3/16 —18 UNEF-2B 1-3/16 —18 UNEF-2B 1-7/16 —18 UNEF-2B 1-3/4—18 UNS-2B 2—18 UNS-2B 1.000 1.000 1.125 1.250 1.250 1.375 1.500 1.625 2.000 2.250 MSA05014 MSA05016 MSA05018 MSA07516 MSA07518 MSA07520 MSA10020 MSA10024 MSA10032 MSA10036 Not CSA Certified. A Fig. 3 Mechanical adapter with internal threads to mate with NPT threaded fittings and MS type fittings. Material: aluminum 106 Dimensions (in.) Fig. B 1 2 3 1 1 3 1 3 3 3 1.175 1.175 1.175 1.356 1.300 1.300 1.431 1.313 1.576 1.738 T&B Conduit Fittings Liquidtight Flexible Nonmetallic Conduit Fittings Specification Sheet—Bullet® Liquidtight Fittings for Liquidtight Flexible Nonmetallic Conduit and Tubing ® Plastic Bullet Liquidtight Fittings Feature: • Fitting assembles to conduit without disassembly and is designed to be installed with positive installation criteria (gland bottoms on body shoulder). Box or Enclosure Wall Conduit or Tubing Application: A series of nonmetallic fittings designed to provide a liquidtight seal when terminating liquidtight nonmetallic conduit (U.L. Type B) or liquidtight nonmetallic tubing to a box or enclosure with knockout opening or a threaded hub. • Rugged low profile nonmetallic body and gland construction (1); the fitting is equipped with a steel locknut to firmly secure fitting to box or an enclosure and a sealing “O” ring. • Captive sealing “O” ring (2) with predetermined compression for a reliable seal at enclosure. • Fitting ferrule designed to accept variations in conduit inside diameter and is tolerant of field conduit cuts (3). • Performance of fitting unaffected by exposure to detergents, cleaners, and sanitizers commonly encountered in food processing plants and typical industrial environment; also unaffected by cutting fluids, wiring pulling compounds and Marine environment. • Meets industry standards for cold impact and simulated hammer blow. Standard Material/Finish: • Body Gland—weather stabilized thermoplastic (black). • “O” Ring—nitrile (blue) • Locknut—Steel/electro-zinc plated • Material temperature rating— thermoplastic -40°C to 105°C. • Ferrule profile designed to reduce friction between conduit I.D. and ferrule (4) allowing conduit to seat properly for an effective seal. • Material Flammability Rating: U.L.94-V2. • Outer surface of clamping fingers provided with friction reducing ridges (5) for ease of installation; the inner surface is designed with conduit biting teeth to enhance clamping and sealing action (6). • U.L.514B • Performance of fittings tested to simulate adverse installation conditions. • Provides a double sealing action (7). • Elongated gland nut profile (8) designed to provide additional strain relief for 90° pull and an easy hand grip. 107 Conformity • CSA C22.2 #227.2 & CSA C22.2 #227.3 • Watertight requirements of NEMA Type 4 and Type 4X. • Federal Standard H-28 (NPT threads) • There is no CEC Rule to use Nonmetallic liquidtight conduit and fittings in Class I, Zone 2 or Class I, Division 2; Rule 18-202 (4) (b) Class II, Division 1; Rule 18-252 (4) Class II, Division 2; Rule 18-302 (4) Class III, Division 1. T&B Conduit Fittings Liquidtight Flexible Nonmetallic Conduit Fittings Plastic Bullet® Liquidtight Fittings for T&B NMC Nonmetallic Liquidtight Conduit Type B and T&B NMT Flexible Tubing Cat. No. Fig. Trade Size LT38P LT438P LT938P 1 2 3 3/8 LT50P LT450P LT950P 1 2 3 1/2 LT75P LT475P LT975P 1 2 3 LT100P LT4100P LT9100P A ±.015 (.040) in. (mm) *B ±.035 (0.90) in. (mm) C ±.015 (0.40) Across Corners in. (mm) Min. Throat Dia. D in. (mm) E Thread NPT F* (in.) (mm) Approx. 1.595 2.012 1.380 (40.51) (51.10) (35.05) 1.354 (34.39) .417 (10.59) 1/2-14 — 1.534 (38.95) 1.880 (47.75) .570 (14.48) 1.636 2.092 1.489 (41.55) (53.14) (37.82) 1.448 (36.78) .550 (13.97) 1/2-14 — 1.590 (40.39) 1.986 (50.44) 3/4 .582 (14.78) 1.757 2.452 1.790 (44.63) (62.28) (45.47) 1.740 (44.20) .740 (18.80) 3/4-14 — 1.821 (46.25) 2.212 (56.00) 1 2 3 1 .726 (18.44) 1.923 2.684 2.104 (48.84) (68.17) (53.44) 2.068 (52.53) .940 (23.88) 1-11-1/2 — 2.034 (51.66) 2.508 (63.70) LT125P LT4125P LT9125P 1 2 3 1-1/4 .750 (19.05) 2.164 3.264 2.564 (54.97) (82.91) (65.13) 2.494 (63.35) 1.257 (31.93) 1-1/4-11-1/2 — 2.385 (60.58) 2.856 (72.54) LT150P LT4150P LT9150P 1 2 3 1-1/2 .767 (19.48) 3.353 3.605 2.854 (59.77) (91.57) (72.49) 2.784 (70.71) 1.453 (36.91) 1-1/2-11-1/2 — 2.604 (66.14) 3.144 (79.86) LT200P LT4200P LT9200P 1 2 3 2 .794 (20.17) 2.605 4.210 3.432 (66.17) (106.93) (87.17) 3.362 (85.39) 1.883 (47.83) 2-8 — 3.050 (77.47) 3.675 (93.34) .570 (14.48) * After Assembly Suggested Specification: Where liquidtight flexible nonmetallic conduit (U.L. and CSA Type B) or liquidtight flexible nonmetallic tubing is terminated to a box or enclosure, the nonmetallic fittings used shall be able to be installed without disassembly and provide a positive installation criteria. In E Thread Figure 1 the installed condition, the fitting must provide a seal meeting watertight requirements of NEMA Type 4 and Type 4X. The performance of fittings shall be unaffected by exposure to detergents, sanitizers, cutting fluids, wire pulling compunds and oil-based industrial E Thread Figure 2 108 paints. The fitting must also be capable of withstanding marine environment and cold impact simulating a hammer blow. Installed fittings shall be of the elongated gland type as manufactured by Thomas & Betts LT38P series. E Thread Figure 3 T&B Conduit Fittings Liquidtight Flexible Conduit Fittings Metallic Bullet® Liquidtight Fittings for T&B NMC Nonmetallic Liquidtight Conduit Type B and T&B NMT Flexible Tubing Cat. No. Fig. Trade Size LT38M LT438M LT938M 1 2 3 LT50M LT450M LT950M 1 2 LT75M LT475M LT975M 1 2 3 3/4 LT100M LT4100M LT9100M 1 2 3 1 LT125M LT4125M LT9125M 1 2 3 1-1/4 LT150M LT4150M LT9150M 1 2 3 LT200M LT4200M LT9200M 1 2 3 A ±.030* (.80) in. (mm) B ±.060 (1.50) in. (mm) C ±.045 (1.15) in. (mm) 1.156 (29.4) 1.500 1.962 1.312 (38.1) (49.8) (33.3) 0.562 0.562 0.625 (14.3) (14.3) (15.9) 1.375 (34.9) 1.562 1.875 1.437 (39.7) (47.6) (36.5) 0.562 0.562 0.625 (14.3) (14.3) (15.9) 1.656 (42.1) 1.625 2.125 1.750 (41.2) (54.0) (44.4) 0.625 0.562 0.625 (15.9) (14.3) (15.9) 1.875 (47.6) 2.062 2.250 1.937 (52.4) (57.1) (49.2) 0.750 0.812 0.812 (19.0) (20.6) (20.6) 2.375 (60.3) 2.500 2.750 2.500 (63.5) (69.8) (63.5) 0.812 0.812 0.812 (20.6) (20.6) (20.6) 1-1/2 2.750 (69.8) 2.687 2.750 2.812 (68.2) (69.8) (71.4) 0.812 0.812 0.812 (20.6) (20.6) (20.6) 2 3.468 (88.1) 3.062 3.875 3.500 (77.8) (98.4) (88.9) 0.812 0.875 0.875 (20.6) (22.2) (22.2) 3/8 1/2 3 D in. (mm) Thread NPT — 1/2-14 1.375 (34.9) — 1/2-14 1.562 (39.7) — 3/4-14 1.750 (44.4) — 1-11-1/2 2.187 (55.5) — 1-1/4-11-1/2 2.750 (69.8) — 2.937 (74.6) 1-1/2-11-1/2 — 2-11-1/2 3.437 (87.3) * After Assembly Suggested Specification: Where liquidtight flexible nonmetallic conduit (U.L. and CSA Type B) or liquidtight flexible nonmetallic tubing is terminated to a box or enclosure, the metallic fittings used shall be able to be installed without disassembly and provide positive installation criteria. In the installed condition, the fitting must provide a seal, meeting watertight requirements of NEMA Type 4 and Type 4X with conduit and NEMA Type 4 enclosures with tubing. Installed fittings shall be as manufactured by Thomas & Betts LT38M series. Figure 1 Figure 2 109 Material: Body/Gland—Steel/MI Insert—Nylon Figure 3 T&B Conduit Fittings Liquidtight Flexible Nonmetallic Conduit Fittings ISO Metric Bullet™ Liquidtight Fittings When you have a conduit application in a liquidtight environment, it's time to load up the T&B Bullet®. Thomas & Betts introduces the ISO Metric Bullet® liquidtight fittings for use with the 3/8”, 1/2”, and 3/4” NMT and NMC nonmetallic liquidtight conduit series. The T&B Bullet® liquidtight fitting and NMT nonmetallic conduit are suited for OEM applications as in the machine tool industry where environments include continuous motion, vibration, and exposure to moisture, oil, dirt and dust. The T&B Bullet® liquidtight fitting and NMT nonmetallic conduit are also suitable for construction applications where ISO metric threading and liquidtight systems are installed. The Xtraflex® system offers a lightweight, liquidtight flexible conduit solution for industrial applications. The Xtraflex® system allows fast, easy installation and high performance in demanding industrial applications. ISO Metric Bullet® Liquidtight Fitting Cat. No. LT38M-ISO20 LT50M-ISO20 LT75M-ISO25 LT438M-ISO20 LT450M-ISO20 LT475M-ISO25 LT938M-ISO20 LT950M-ISO20 LT975M-ISO25 Angle of Fitting Conduit Size (in.) Knockout Size (in.) Unit Package Standard Package UPC Number Straight Straight Straight 45° 45° 45° 90° 90° 90° 3/8 1/2 3/4 3/8 1/2 3/4 3/8 1/2 3/4 1/2 1/2 3/4 1/2 1/2 3/4 1/2 1/2 3/4 25 25 25 25 25 10 25 25 10 100 100 50 50 50 50 50 50 50 786210-62281 786210-62282 786210-62283 786210-62284 786210-62285 786210-62286 786210-62288 786210-62289 786210-62290 ISO Metric Bullet® Liquidtight Fitting Nonmetallic Cat. No. LT38P-ISO20 LT50P-ISO20 LT75P-ISO25 LT938P-ISO20 LT950P-ISO20 LT975M-ISO25 Angle of Fitting Conduit Size Knockout Size Unit Package Standard Package UPC Number Straight Straight Straight 90° 90° 90° 3/8” 1/2” 3/4” 3/8” 1/2” 3/4” 1/2” 1/2” 3/4” 1/2” 1/2” 3/4” 25 25 25 25 25 10 100 100 50 50 50 50 786210-66444 786210-66613 786210-66443 786210-66612 786210-66640 786210-66611 110 T&B Conduit Fittings Armoured Cable and Flexible Metal Conduit Fittings Specifications — Armoured Cable and Flexible Metal Conduit Armoured Cable (Type AC90) Ref. CEC Rule 12-600 The Canadian Electric Code 2009 Part I defines type AC armoured cable as, “A fabricated assembly of insulated conductors in a flexible metallic enclosure.” All armoured cables may employ copper or aluminum or copperclad aluminum conductors with the following sizes and are rated for 600 volts or less: No. 14 AWG to No. 1 AWG Copper No. 12 AWG to No. 1 AWG Aluminum or Copperclad Aluminum Armoured cable can be used for both exposed or concealed locations. Armoured cable is not permitted in locations where it will be subjected to physical damage or corrosive fumes. Armoured cable cannot be used for direct burial in earth. Codes require that cable shall be supported with straps or staples without damaging conductors. Certain precautions are prescribed in code where cable is installed through joist rafters or similar wood members. According to CEC Rule 12-610 (1) Where conductors issue from armour, they shall be protected from abrasion by bushings of insulating material or equivalent devices. (2) Where conductors are No. 10 AWG or larger, copper or aluminum, such protection shall consist of: (a) Insulated type bushings, unless the equipment is equipped with a hub having a smoothly rounded throat; or (b) Insulating material fastened securely in place which will separate the conductors from armoured cable fittings and afford adequate resistance to mechanical injury. (3) Where armoured cable is fastened to equipment, the conductor or clamp shall be of such design as to leave the insulating bushing or its equivalent visible for inspection. (4) Where conductors connected to open wiring issue from the ends of armouring, they shall be protected with boxes or with fittings having a separately bushed hole for each conductor. Please refer to the following for further details and complete information: 1. U.L. 4, ANSI C33.9….............Safety Standards for Armoured Cable 2. U.L. 514 .................................Safety Standards for Outlet Boxes and Fittings 3. W-F-406… .....Federal Specification: Fittings for Cable, Power, Electrical and Conduit, Metal, Flexible 4. NEMA FB-1… ..Standards Publication: Fittings & Supports for Conduit and Cable Assemblies 5. CEC Section 12-600… ..........Wiring Methods (Armoured Cable) 6. CSA C22.2 No. 51… .............Safety Standards for Armored Cables 7. CSA C22.2 No. 18… .............Safety Standards for Outlet Boxes, Conduit Boxes and Fittings Please Note The excerpts and other material herein, whether relating to the Canadian Electrical Code 2009 Part I, the Underwriters Laboratories, Inc. listing, to industry practice or otherwise, is not intended to provide all relevant information required for use and installation. Reference to original or primary source material and data is mandatory before any application or use is made of the product. 111 T&B Conduit Fittings Armoured Cable and Flexible Metal Conduit Fittings Specifications — Armoured Cable and Flexible Metal Conduit (continued) Flexible Metal Conduit Ref. CEC Rule 12-1000 Flexible metal conduit can be used for exposed or concealed work in dry locations. It can be used for wet locations provided conductors within are lead covered or other approved type. Flexible metal conduit cannot be used underground or embedded in poured concrete or aggregate. With rubber covered conductors the conduit cannot be exposed to oil, gasoline or other materials having a deteriorating effect on rubber. With minor exceptions use of flexible metal conduit is not permitted in hoists, in storage battery rooms and in any hazardous locations. Use of flexible metal conduit is restricted to systems under 600 volts. Flexible metal conduit longer than six feet is permitted to be used as a grounding means provided the conduit and the fitting are approved for the purpose. To date there is no flexible metal conduit approved for the purpose by the Underwriters Laboratories or CSA. In Class II Zone 2 and Division 2 hazardous areas, the conduit itself cannot be used as the grounding means. Class I Zone 2, flexible connections at motor terminals and similar places, ref.: CEC Rule 18-152 (6) and Bonding CEC Rule 18-074 (1)(a). Class I Division 2, flexible connections at motor terminals and similar places, ref: CEC Rule J18-152 (3) and Bonding CEC Rule J18-072 (1)(a). Flexible metal conduit is available with steel or aluminum armour in trade size 5/16” to 4”. With few exceptions where 5/16 and 3/8 trade sizes are used, Code prohibits use of conduit less than 1/2” trade size. Bends in concealed work are restricted to four 90° bends CEC Rule 12-940. No angle fittings are permitted in concealed raceway installations. 112 Please refer to the following for further details and complete information: 1. U.L. 1, ANSI C33.92…...........Safety Standards for Flexible Metal Conduit 2. U.L. 514.................................Safety Standards for Outlet Boxes and Fittings 3. W-F-406… .....Federal Specification: Fittings for Cable, Power,Electrical and Conduit, Metal Flexible 4. WW-C-566… .....Federal Specification: Conduit, Metal, Flexible 5. NEMA FB1… Standards Publication: Fittings and Supports for Conduit and Cable Assemblies 6. CEC 12-1000… ........Wiring Method (Rigid & Flexible Conduit) 7. CSA C22.2 No. 56… .............Safety Standards for Flexible Metallic Conduit and Liquid-Tight Flexible Metal Conduit 8. CSA C22.2 No. 18… .............Safety Standards for Outlet Boxes, Conduit Boxes and Fittings 9. CEC Rule 12-1000 Rule 18-152 (6) and Bonding Rule 18-074 (1)(a) Class I, Zone 2 Flexible connections at motor terminals and similar places. Rule J18-152 (6) and Bonding Rule J18-072 (1)(a) Class I, Division 2 Flexible connections at motor terminals and similar places. Rule 12-940 ........Not more than the equivaleent of four 90° bends CEC T&B Conduit Fittings Armoured Cable and Flexible Metal Conduit Fittings Suggested Specifications for Armoured Cable and Flexible Metal Conduit Fittings Series 3110 Armoured Cable Fitting & Flexible Metal Conduit Series 422 Insuliner Sleeve • Armoured cable and flexible metal conduit shall conform to provisions of following applicable standards: Armoured Cable…U.L. 4/ANSI C33.9/CSA C22.2 No. 51 Flexible Metal Conduit…U.L. 1/ANSI C33.92/WW-C-566/CSA C22.2 No.56 • Type of cable used and conductors within flexible metal conduit shall be suitable for conditions of use and location. • Where armoured cable or flexible metal conduit terminates into a threadless or threaded opening it shall be assembled with approved fittings; fittings shall be of malleable iron/steel construction, electro-zinc Series 390 Anti Short Bushing 113 plated inside outside, equipped with nylon insulated throat and shall be of angled saddle type as manufactured by Thomas & Betts, series 3110. Direct bearing screw type fittings shall not be used. • Suitable bushing as manufactured by Thomas & Betts, series 422 or 390, shall be provided between the conductors and armour. • Where approved armoured cable or flexible metal conduit is used as an equipment grounding conductor terminating fitting used shall be of the grounding type as manufactured by Thomas & Betts, series 3110. T&B Conduit Fittings Armoured Cable and Flexible Metal Conduit Fittings Specifications • Rugged all steel or malleable iron construction. Application • To connect and effectively bond armoured cable or flexible metal conduit to a box or an enclosure. 3110 Series Features • Provided with a saddle designed to: (1) Firmly secure conduit in place without damaging cable armour (Mechanical holding power of angled wedge assembly increases with increased strain.). (2) Provide high quality bond between conduit or cable and are unaffected by vibrations. (3) Centralize conduit or cable with respect to throat opening for conductors. • Insulated throat protects conductors during and after installation, reduces wire pull effort and prevents thread damage in handling. • Locknuts designed to provide effective bond between fitting and box or enclosure, will not vibrate loose. • CEC Rule 18-152 (6) and Bonding Rule 18-074 (1)(a) Class I, Zone 2 Flexible connections at motor terminals and similar places. CEC Rule J18-152 (6) and Bonding Rule J18-072 (1)(a) Class I, Division 2 Flexible connections at motor terminals and similar places. Standard Material/Finish Body: Steel or malleable iron/ Electro Zinc Plated & Chromate Coated Saddle: Steel/Electro Zinc Plated & Chromate Coated Screws: Steel/Electro Zinc Plated & Chromate Coated Insulator: Thermoplastic/As Molded Conformity U.L. 514B CSA C22.2 No. 18.3 NEMA FB-1 • Designed with fewer screws— reduces installation time and cost. Series Cable Opening Hub Size Conduit Size 3110 Series Straight Fittings 1/2" thru 5" NPS 3/8" thru 5" .437" to 5.500" 3130 Series 90° Fittings 1/2" thru 4" NPS 3/8" thru 4" 4.560" .437" to (All hubs provided with straight pipe threads NPS.) Saddle Locknut Body Insulated Throat 114 Box or Enclosure Wall Typical Installation T&B Conduit Fittings Armoured Cable and Flexible Metal Conduit Fittings ® Tite-Bite Fittings—Nylon Insulated Steel or malleable iron. The tough lining of insulation and the Tite-Bite principles make these fittings a “must” when conductors are subject to conditions of vibration or strain. Cat. No. Cable Opening (in.) max. min. 3110-C* 3112 3115* 3117* 3118† 3119† 3120† 3121† 3122† 3123‡ 3124**† 3125** .656 .937 1.125 1.468 1.750 2.031 2.500 3.062 3.562 4.060 4.560 5.500 .437 .750 .906 1.250 1.562 1.812 2.312 2.812 3.312 3.620 4.120 4.600 Dimensions (in.) B Trade Size K.O. Size A 3/8” 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 3-1/2” 4” 5” 1/2” 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 3-1/2” 4” 5” 1-7/16 1-25/32 2 2-3/8 2-3/4 3-1/8 3-3/4 4-3/8 5 5-1/4 5-3/4 6-7/8 Trade Size K.O. Size A 3/8” 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 1/2” 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 7/16 1-7/64 1-7/32 1-1/8 1-1/4 1-3/4 1-13/16 2-1/4 2-1/4 1-5/16 1-3/4 1-3/4 1-3/4 2 2-5/8 2-3/4 3-1/4 3-1/4 3-11/16 3-25/32 4-27/32 C 7/16 1-9/32 1-9/32 1-7/32 1-11/32 1-7/8 1-15/16 2-3/8 2-3/8 2-15/32 2-1/2 3 Material: Steel thru 3/4” trade size. * U.L. Listed for armoured cable only. † U.L. Listed for flexible metal conduit only. ‡ CSA not applicable. ** Not U.L. Listed or CSA Certified. ® Tite-Bite Fittings Steel or malleable iron. Easy to install with double grip saddle. These fittings are completely salvageable. The 2/3” and 1/2” sizes are made of formed steel which produce a uniform high quality and a smooth throat that protects conductor insulation. 3/4” and larger size are malleable iron. Cat. No. Cable Opening (in.) max. min. 300-TBC* 302-C 304 306 308† 310† 312† 314† 316† .656 .937 1.093 1.468 1.750 2.031 2.500 3.062 3.562 .437 .750 .906 1.250 1.562 1.812 2.312 2.812 3.312 Material: Steel thru 3/4” trade size. * U.L. Listed for armoured cable only. † U.L. Listed for flexible metal conduit only. 115 Dimensions (in.) B 1-5/16 1-11/16 1-11/16 1-3/4 2-1/32 2-9/16 2-13/16 3-1/8 3-3/16 C 7/16 3/4 29/32 1-1/4 1-9/16 1-13/16 2-5/16 2-13/16 3-5/16 T&B Conduit Fittings Armoured Cable and Flexible Metal Conduit Fittings ® Tite-Bite Fittings—90° Angle Nylon Insulated Steel or malleable iron. Available with or without insulated throat, this Tite-Bite fitting line is by far the easiest and best to install when making sharp bends at the enclosure or equipment. It has all of the advantages of the straight fitting with only one screw to tighten, except in the larger sizes where there are two. A peep hole on top provides for easy inspection of the ABC bushing. Narrow design makes it easy to install fittings in adjacent knockouts. Cat. No. Cable Opening (in.) max. min. 3130-C 3132 3135 3137 3138† 3139† 3140† 3141† 3142† 3143‡ 3144-TB‡ .563 .937 1.093 1.468 1.750 2.031 2.500 3.062 3.562 4.060 4.560 † ‡ .437 .750 .906 1.250 1.562 1.812 2.312 2.812 3.312 3.620 4.120 Dimensions (in.) B Trade Size K.O. Size A 3/8” 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 3-1/2” 4” 1/2” 1/2” 3/4” 1” 1-1/4” 11-1/2” 2” 2-1/2” 3” 3-1/2” 4” 1-11/32 1-7/8 2 2-21/32 3-1/8 4-3/8 5-9/16 5-25/32 6 6 6-29/32 Trade Size K.O. Size A 3/8” 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 1/2” 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 1-11/32 1-7/8 2-1/8 2-21/32 3-1/8 4-1/8 4-3/8 6-1/2 5-25/32 1-19/32 2-5/16 2-1/8 2-1/8 2-7/8 4 4-7/8 6 7 6-7/8 7-1/4 C 5/32 1-5/32 1-5/32 1/2 3/4 1-3/16 1 21 1 1-1/16 1-1/8 U.L. Listed for flexible metal conduit only. Not U.L. Listed or CSA Certified. ® Tite-Bite Fittings — 90° Angle The angle clip gives secure mechanical grip that tightens under tension or vibration. Throat is long enough to install in cast housing knockouts. The 3/8” and 1/2” sizes are of steel construction. The 3/4” and larger sizes are malleable iron. Cat. No. Cable Opening (in.) max. min. 321-C 323 325 326-TB 327† 328† 329† 330-TB† 331† .656 .937 1.093 1.468 1.750 2.031 2.500 3.062 3.562 † .437 .750 .906 1.250 1.562 1.812 2.312 2.812 3.312 U.L. Listed for flexible metal conduit only. 116 Dimensions (in.) B 1-1/2 2-3/8 2-1/8 2-1/8 3-5/8 4-1/8 4-31/32 6 7 C 3/8 1-7/32 3/4 1 — — — — — T&B Conduit Fittings Armoured Cable and Flexible Metal Conduit Fittings Squeeze Fittings T&B squeeze fittings will fit every size of armoured cable, leaded cable and flexible conduit. Malleable iron or steel construction. Part No. 253-TB is steel. Cat. No. Cable Opening (in.) max. min. 252 253-TB† 254-C† 255 256 257 258 259 249 277 .531 .585 .938 1.094 1.375 1.656 1.875 2.500 3.062 3.563 † .437 .455 .812 .938 1.250 1.500 1.688 2.313 2.812 3.312 Dimensions (in.) B Trade Size K.O. Size A 5/16” 3/8” 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 3/8” 1/2” 1/2” 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 13/16 31/32 1-7/32 1-1/4 1-19/32 1-7/8 2-1/4 2-31/32 3-5/16 3-13/16 C 25/32 1-13/64 1-3/8 1-17/32 1-5/8 1-23/32 1-7/16 2-5/8 2-11/16 2-7/8 11/32 5/8 13/32 7/16 1/2 17/32 9/16 11/16 3/4 3/4 Dimensions (in.) B C U.L. Listed for armoured cable only. Fitting material steel. Squeeze Fittings—90° Angle Cat. No. 3/8” and 1/2” sizes made in steel. Cap lifts off by simply loosening screws part way. Only two screws to tighten. 3/4” size and larger made of malleable iron. 266-C* 272† 268-C 279 270 273-TB 274‡ 275‡ 276‡ † ‡ Cable Opening (in.) max. min. .656 .812 .937 1.000 1.125 1.406 1.656 1.875 2.500 .406 .688 .813 .875 1.000 1.187 1.375 1.625 2.125 Trade Size K.O. Size A 3/8” 3/8” 1/2” 3/4” 3/4” 1” 1-1/4” 1-1/2” 2” 1/2” 1/2” 1/2” 3/4” 3/4” 1” 1-1/4” 1-1/2” 2” 1-1/2 1-9/16 1-11/16 1-13/16 1-7/8 2-3/8 3 3-7/32 4-5/8 1-13/32 1-7/8 1-13/16 2-1/16 1-3/4 2-7/32 2-9/16 3-1/16 3-5/8 1-7/16 1-9/16 1-7/8 1-13/16 1-13/16 2-7/16 2-7/8 4-1/8 4-7/8 U.L. Listed for armoured cable only. U.L. Listed for flexible metal conduit only. Squeeze Fittings—45° Angle Cat. No. Cable Opening (in.) max. min. Trade Size K.O. Size A Dimensions (in.) B C 265* 267 269 .656 .937 1.125 3/8” 1/2” 3/4” 1/2” 1/2” 3/4” 1-7/16 1-3/16 1-7/8 1-5/32 1/2 17/32 1-1/8 1-1/4 1-9/16 3/8” and 1/2” sizes made in steel. Cap lifts off by simply loosening screws part way. 117 .406 .813 1.000 T&B Conduit Fittings Armoured Cable and Flexible Metal Conduit Fittings Two-Screw Fittings Cat. No. Cable Opening (in.) max. min. 3301-C* 3312-C .656 .937 Trade Size .250 .500 K.O. Size 3/8” 1/2” 1/2” 1/2” A Dimensions (in.) B C 5/8 5/8 1-5/16 1-5/16 1-3/16 1-3/16 * U.L. Listed for armoured cable only. Formed steel body with carefully round bushing. The armour gripping saddle stays open by itself when cable is being inserted. Duplex Clamp Fitting Dimensions (in.) Cat. No. K.O. Size A B 291-C 1/2” 1-13/32” 1-11/16” U.L. Listed as grounding means under NEC 350-5. Malleable iron. For nonmetallic and armoured cable. Adaptor—EMT to Flex Cat. No. 503-TB 504 505-TB A C (max) B ® Tite-Bite fitting design holds flexible metal cable firmly in place with a single screw rather than two screws. 118 K.O. Size A Dimensions (in.) B C 1/2” - 1/2” 3/4” - 3/4” 1” - 1” 1-21/32 1-25/32 2-1/32 1-3/16 1-7/16 2-1/16 1-7/8 2-1/8 2-5/8 T&B Conduit Fittings Armoured Cable and Flexible Metal Conduit Fittings Combination Coupling Cat. No. Size Flex to EMT A Dimension (in.) B C 449C 3/8” - 1/2” 1-21/32 1-11/32 15/16 Cable opening: max. .656, min. .250 A one piece fitting that couples 3/8” flexible metal conduit to 1/2” electrical metallic tubing (EMT) 1-21/32 15/16 C 1-11/32 15/16 A B Anti-Short Bushing Anti-short bushings are made of smooth plastic, and designed to protect conductor insulation from rough edges of armoured cable and flexible metal conduit. Cat. No. Size 390 391 392 393 394 14-2, 14-3, 12-2 14-4, 12-3, 6-1, and 4-1 12-4, 10-2, 10-3 and 2-1 10-4, 8-2, 8-3, and 1-1 8-4, 6-2, 6-3, 4-2, 4-3, and 6-4 Colorized Temperature Rating: 240°F U.L. not applicable. Strap Cat. No. 65C Bolt Hole Dia. .265” 119 Size 3/8” Flex T&B Conduit Fittings Nonmetallic Sheathed Cable Fittings Specifications — Nonmetallic (NM) Sheathed Cable Ref. CEC Rule 12-500 Canadian Electrical Code 2009 Part I, defines Nonmetallic Sheathed Cable as, “A factory assembly of two or more insulated conductors having an outer sheath of moisture resistant, flame retardant, nonmetallic material.” Nonmetallic sheathed cable is constructed of insulated conductors (14 to 2 AWG copper), and an outer nonmetallic sheath classified as Types NMD90, NMW and NMWU. Nonmetallic sheathed cable is provided with bare bonding conductor. Nonmetallic sheathed cable is rated for 90°C service with voltage limitation of 300 volts. Type NMW and NMWU have a flame retardant, moisture resistant sheath. Type NMD90, NMW and NMWU applications are described in Table 19 of CEC 2009 Part I. Nonmetallic sheathed cable is permitted by code to be used exposed or concealed in one, two or multifamily dwellings or other structures not exceeding three floors. Use of Type NMD90 cable is restricted to dry locations. Nonmetallic sheathed cables are not permitted to be used as a service conductor. Nonmetallic sheathed cables are also prohibited in hazardous locations. NM cables need to be secured in place by suitable means so as not to injure the cable. Adequate protection for cable is also required when run is exposed, through joists or rafters, through floors, in unfinished basements and accessible attics. NM cables shall be protected from physical damage when it passes through factory or field punched, cut or drilled holes in metal members. A bushing or grommet firmly secured in place is recommended (CEC Rule 12-516). Please refer to the following for further details and complete information: 1. U.L. 719, ANSI C33.56 ..........Safety Standards for Nonmetallic Sheathed Cable 2. U.L. 514.................................Safety Standards for Outlet Boxes and Fittings 3. NEMA FB-1… ..Standards Publication: Fittings and Supports for Conduit and Cable Assemblies 4. CEC Section 12-500 ..............Wiring methods (Nonmetallic Sheathed Cable) 5. CSA C22.2 No. 48… .............Safety Standards for Nonmetallic Sheathed Cable 6. CSA C22.2 No. 18… .............Safety Standards for Outlet Boxes, Conduit Boxes and Fittings Please Note The excerpts and other material herein, whether relating to the Canadian Electrical Code 2009 Part I, the Underwriters Laboratories, Inc. listing, to industry practice or otherwise, is not intended to provide all relevant information required for use and installation. Reference to original or primary source material and data is mandatory before any application or use is made of the product. 120 T&B Conduit Fittings Nonmetallic Sheathed Cable Fittings Suggested Specifications for Nonmetallic Sheathed Cable • Where nonmetallic sheathed cable or flexible cord terminates into a threaded or threadless opening, terminating fittings used shall be approved for the purpose by nationally recognized laboratory, inspection agency or product evaluation organization. Series 3300 Nonmetallic Sheathed Cable and Flexible Cord Fittings (All Plastic) • Terminating fittings shall be of malleable iron, steel, or thermoplastic construction designed to provide adequate strain relief and positively prevent damage to jacket or conductor insulation such as series 3300 or 3302M manufactured by Thomas & Betts. Ferrous metal fittings shall be electro-zinc plated inside and outside including threads and bushed with a nylon insulated throat. Series 3302M Nonmetallic Sheathed Cable and Flexible Cord Fittings (Steel) Series 3210 Knockout Bushings Series 1942 Insulated Nipples 121 Thermoplastic material used for fitting construction shall be of high impact strength suitable for 105°C/221°F service with a U.L. flammability rating of 94V-1. • Where nonmetallic sheathed cable passes through either factory or field punched, cut or drilled holes in metallic members, the cable shall be protected by thermoplastic bushing such as series 3210 manufactured by Thomas & Betts. Bushing shall be firmly secured in opening. Nylon bushed metallic fittings such as Thomas & Betts series 1942 may be substituted as required. T&B Conduit Fittings Nonmetallic Sheathed Cable Fittings Nonmetallic Sheathed Cable & Flexible Cord Fittings (Steel) Application • To connect nonmetallic sheathed cable and flexible cord to a box or an enclosure. Features • Rugged all steel/malleable iron construction (A). 3302M Series Nonmetallic Sheathed Cable Fitting • Rounded cable clamp grip provides superior mechanical holding power without damaging conductor insulation or outer jacket (B). Typical Installation • Clamp designed to cover body opening for a neat and safe installation. (D) • Screws thread into clamp and not body; screw heads are snug with body and ends of screws do not project beyond the body (C). Locknut Box or Enclosure Wall • Insulator firmly secured in place protects conductors and reduces wire pulling effort; protects threads from damage during handling (D). • Locknut designed to secure fitting to a box or enclosure; will not vibrate loose. (A) (B) Typical Installation (Flexible Cord) (C) Typical Installation (NM-Sheathed Cable) 122 Standard Material Body 1/2” thru 1” Steel; 1-1/4” thru 2” Malleable Iron Clamp 1/2” thru 1-1/4” Steel; 11/4” thru 2” Malleable Iron Locknut All Steel Insulator Thermoplastic Standard Finish All steel and malleable iron parts— Electro Zinc Plated & Chromate Coated Range • Hub Size 1/2” thru 2” Hubs provided with straight pipe threads (NPS.) • Cable 2 #14 thru 4 #4 Type NM • Cable Outside Diameter 0.250” to 1.150” Conformity U.L. 514B CSA C22.2 No. 18.3 NFPA 70-2008 (ANSI) NEMA FB-1 Federal Standard H-28 (Threads) T&B Conduit Fittings Nonmetallic Sheathed Cable Fittings Two-Screw Fittings Steel or malleable iron. Rounded cable grip and smooth bushing protect the cable sheath and wire insulation. Since saddle is threaded, screws do not travel or extend beyond the fitting body as it is clamped to the cable. An extra lip on the saddle closes the unused part of the fitting opening. Cat. No. Noninsulated 3302* Insulated 3302M-C K.O. Size U.L. Listed & CSA Certified for the following Single (1) and Pairs of (2) NM & NMC Cable U.L. Listed & CSA Certified for the following Service Entrance Cables A Dimensions (in.) B C 1/2” (1) 2#14, 2#12, 2#10, 3#14, 3#12, 3#10, (2) 2#14, 2#12 2#12 thru 2#4, 3#12, 3#10 31/32” 1-3/8” 1” (1) 2#8, 2#6, 3#8 (2) 2#12, 2#10, 2#8, 3#14 2#8 thru 2#1/0, 3#8, 3#6, 1-1/4” 1-5/8” 1-3/16” 2#6 + #8 GND Cable Opening max. min. .590 .250 .750 .530 3303-C 3303M 3/4” 3304 3304M 1” (1) 3#8, 3#6, 3#4 (2) 2#8, 3#10 2#1, 2#1/0, 3#6 thru 3#2, 2#4 + #6 GND, 2#3 + #5 1-15/32”1-7/8” 1-1/4” GND, 2#2 + #4 GND .990 .690 3305 3305M 1-1/4” (1) 3#8, 3#6, 3#4 (2) 2#8, 2#6, 2#4, 3#8 3#2 thru 3#2/0, 2#1 + #3 GND, 2#1/0 + #2 GND, 1-15/16”2-7/32”1-9/32” 2#2/0 + #1 GND 1.320 .850 3306 3306M 1-1/2” 1.515 .930 3307 3308† 3309† 3310† 3311† 3307M — — — — 2” 2-1/2” 3” 3-1/2” 4” 2-25/32”3-5/16”1-29/32” 1.980 1.150 (1) 3#4 3#3/0, 3#4/0, 2#3/0 + #1/0 2-5/32”2-21/32”1-5/8” GND, 2#4/0 + #2/0 GND Max. 1.98”, Min. 1.15” Max. 2.38”, Min. 1.5” Max. 2.88”, Min. 1.75” Max. 3.38”, Min. 2.25” Max. 3.88”, Min. 2.5” — * U.L. Listed for use with rubber and thermoplastic flexible cords (both single and multiple cords and 2 oval cables). U.L. Listed for multiple cords and cables. 123 T&B Conduit Fittings Nonmetallic Sheathed Cable Fittings Nonmetallic Sheathed Cable and Flexible Cord Fittings (All Plastic) Application • To connect nonmetallic sheathed cable and flexible cord to a box or an enclosure. Features • Provides strain relief by partially deflecting cable (A); therefore: (1) Fitting will not damage outer covering or jacket of cable, or conductor insulation; designed to give safe trouble-free installation. (2) Holding power and cable strain relief are not effected by surface finish of outer covering or cable jacket. (3) Fitting provides superior holding power far in excess of listing agency requirements. 3300 Series Box or Enclosure Wall (C) Cable or Cord (B) (A) • Snap-in one piece design; accommodates variation in knockout dimensions, saves installation time (B). • All high impact thermoplastic construction provides: (1) Insulated throat; conductors are protected from abrasion. (2) Improved dielectric strength, and elimination of potential shorts. (3) Corrosion resistance. • Wide range—reduces inventories • Fitting may be pre-installed in box K.O., or on cable. Standard Material All high impact thermoplastic—U.L. Class 94V-1 suitable for 105°C application. Standard Finish As Molded Listing/Certification Cat. No. 3201, 3350 for factory installation Conformity U.L. 514B CSA C22.2 No.18.3 NFPA 70-2008 (ANSI) Typical Installation Range 1. Remove sheath from end 2. Insert button into cavity. of cable (4” or more as required). Insert cable through fitting as shown (Cable under button). 4. Snap fitting into knockout box. If desired this step can be done prior to Step 1. 3. With grooved pliers, or parallel jaw type pliers (commercially available) squeeze button into cord or wires as far into fitting body as possible. Note: It may be necessary to readjust pliers to insure button is properly installed. 5. To remove from knockout box 6. To remove from cable cut fitting as shown depress ears. 124 Cat. No. Knockout Size 3300 1/2” 3201 & 3350 1/2” 3202 3/4” Cable/ Cord Range 10-2, 12-2 & 14-2 type NM Cable .125” to .300” outside diameter cord 10-3, 12-3, 14-3, 102, 12-2, 14-2 Type NM Cable; also multiple (2) 12-2 and 14-2 Type NM Cable; .300” to .600” outside diameter cord 8-3 and 6-3 type NM cables; also Multiple (2) 14-3 and 10-2 Type NM Cable; .500” to .850” outside diameter cord T&B Conduit Fittings Nonmetallic Sheathed Cable Fittings All Plastic Fitting for NM Cable and Flexible Cord H Hole Size Cat. No. Size Range 3300 For use with 10-2, 12-2 and 14-2 NM cables; 18-2 and 18-3 SJ and SJO cords and 18-2 SV, SVO, SJT and SJTO cords, single or multiple; cord capacity .125-.300 diameter Figure 1 3350 H Hole Size Figure 2 High impact thermoplastic. U.L. 94-V1. Features push-in design. Captive locking wedge secures cable with single squeeze of standard electrician’s pliers. Provides excellent insulation, strain-relief and high pull-out value. 3202 K.O. Size Fig. 1/2” 2 A Dimensions (in.) B C D 1-1/32 15/16 For use with 10-3, 12-3, 14-3, 10-2, 12-2, 4-2 NM cables; multiple (2) 12-2 and 14-2 N 1/2” M cables; single and multiple flexible cords in wire range .300 in. to .600 in. 1 1-11/32 For use with 8-3 and 6-3 NM cables; (2) 14-3, 14-2, 12-2 and 10-2 NM 3/4” cables; single and multiple flexible cords in wire range .500 in. to .850 in. 1 1-1/2 1-5/16 Temperature Rating: 105°C Snap captive locking wedge into fitting’s cavity. Press locking wedge into cavity which locks onto cable. Cat. No. 3201 is ideal for multiple flexible cords and cable. 125 1 E F Max. Thk. Enclosure H 3/8 .880 .795 .080 5/16 x 9/16 7/16 .880 .795 .080 21/32 dia. 7/16 1.100 1.005 .090 7/8 dia. T&B Conduit Fittings Nonmetallic Sheathed Cable Fittings Snap-in Fitting for Flexible Metal Conduit Cat. No. Conduit Size K.O. Size A B C 100TB 100BP 3/8” 3/8” 1/2” 1/2” 27/32 27/32 1-13/32 1-13/32 1-31/32 1-31/32 Temperature Rating: 105°C U.L. 94-V1 No locknut required. No special tools required. High impact thermoplastic with steel insert. Swivel Tray Clamp Cat. No. Conduit Size 6209 6211 6214 6216 6218 1/2”-3/4” 1”-1-1/4” 1-1/2”-2” 2-1/2”-3” 3-1/2”-4” Swivel cable tray clamps for aluminum and steel trays with regular or reinforced flanges. • Serrations and biting teeth on clamping saddle provides a high quality bond between conduit and clamp • 1/2” to 6” sizes that can be clamped to any position in a 90° arc • Hardened steel screws bite into tray and provide positive bond • Malleable iron hub and steel u-bolt accepts conduit from any angle Cable Tray Clamp Cat. No. Conduit Size 6210 6212 1/2”-3/4” 1”-1-1/4” 126 T&B Conduit Fittings Liquatite® Flexible Conduit — Application Guide High Listed for Metal Plastic*** Mech. Direct Halogen Used** Used Strength Burial Free Low Accepts Std. Fire Liquidtight Self EMI/RFI Hazard Fittings Extinguish Shielding Approval Conduit Type Page Flexibility* TYPE-LT 129 B S P pp.92-94 JIC TYPE-LOR 130 B S P pp.92-94 JIC TYPE-EF 130 B S P pp.92-94 JIC TYPE-LA 131 C S P X X pp.92-94 X TYPE-CBLA 132 C S P X X pp.92-94 X TYPE-CSA 133 C S P X pp.92-94 X TYPE-ATLA 134 C S P X pp.92-94 X TYPE-AT 135 B S P TYPE-ATX 135 B S T TYPE-ALT 136 C A P TYPE-CEA 137 C S U X X pp.92-94 X TYPE-ACEA 138 C A U X X pp.92-94 X TYPE-ZHLA 139 C S U X X X X pp.92-94 X TYPE-LAS 140 C S P X X pp.92-94 X X TYPE-EMS 141 C B P pp.92-94 X X TYPE-EMSP 141 C B P pp.92-94 X X TYPE-BR 142 C S TYPE-ABR 143 C TYPE-USL 144 TYPE-SL X pp.92-94 X p.91 pp.92-94 X pp.115-119 -3/8 A pp.115-119 -3/8 B S pp.115-119 144 A, B S pp.115-119 TYPE-VJC 145 A, B S TYPE-UG 145 C S TYPE-LNM-P 146 A P TYPE-NMC 147 C P X TYPE-NMT 147 A P X TYPE-CL 148 C N X TYPE-CLL 148 B TYPE-CCG 149 TYPE-CLR TYPE-CLFR P pp.115-119 pp.115-119 p.102 X pp.108-110 X pp.108-110 X X p.150 X N X p.150 X B N X p.150 149 A N X p.150 X 149 C N p.150 X * A=Continuous flexing B= Small bend radius X C=Flexible D=Pliable (static) 127 X X X ** S=Steel A=Aluminum B= Bronze *** P=PVC U=Pu T=TPR N=Nylon T&B Conduit Fittings Liquatite® Flexible Conduit — Application Guide Temperature Range Conduit Type °C °F -60 -76 -40 -40 -20 -4 TYPE-LT I I TYPE-LOR I TYPE-EF 0 +32 General Chemical Resistance See chart on page 156 Oils Acids +50 +122 +60 +140 +75 +167 +80 +176 +90 +194 +105 +221 +150 +302 I I I I I I I I X X I I I I I I I I I X X I I I I I I I I I I X X TYPE-LA I I I I I I I I I I X X TYPE-CBLA I I I I I I I I I I X X TYPE-CSA I I I I I I I I I I X X TYPE-ATLA I I I I I I I I I I X X TYPE-AT I I I I I I I I I I X X TYPE-ATX I I I I I I I I I I X TYPE-ALT I I I I I I I I I I X TYPE-CEA I I I I I I I I I I X TYPE-ACEA I I I I I I I I I I X TYPE-ZHLA I I I I I I I I I I X TYPE-LAS I I I I I I I I I I X X TYPE-EMS I I I I I I I I I I X X TYPE-EMSP I I I I I I I I I I X X TYPE-BR I I I I I I I I I I TYPE-ABR I I I I I I I I I I TYPE-USL I I I I I I I I I I TYPE-SL I I I I I I I I I I TYPE-VJC I I I I I I I I I I X X TYPE-UG I I I I I I I I I I TYPE-LNM-P I I I I I I I I I I X X TYPE-NMC I I I I I I I I I I X X TYPE-NMT I I I I I I I I I I X X TYPE-CL I I I I I I I I I I X TYPE-CLL I I I I I I I I I I X TYPE-CCG I I I I I I I I I I X TYPE-CLR I I I I I I I I I I X TYPE-CLFR I I I I I I I I I I X 128 X T&B Conduit Fittings Liquatite® Flexible Conduit — Steel JIC Type LT Trade Size (in.) Cat. No. Carton Content* (m) Cat No. 1/4 LT025-75 75 5/16 LT032-75 75 3/8 LT038-30 30 LT038-150 1/2 LT050-30 30 LT050-150 3/4 LT075-30 30 LT075-150 1 LT100-30 30 LT100-120 1-1/4 LT125-15 15 LT125-75 1-1/2 LT150-15 15 LT150-45 2 LT200-15 15 LT200-30 2-1/2 LT250-8 8 LT250-80 3-1/2 LT350-8 8 LT350-50 4 LT400-8 8 LT400-30 5 LT500-8 8 6 LT600-8 8 See Chart on p.155 for dimensions and tolerances. * See p.155 for label and packaging detail. Reel Content* (m) Cat No. 150 150 150 120 75 45 30 80 50 30 - LT038-300 LT050-300 LT075-300 - Reel Content* (m) 300 300 300 Type LT A general purpose, flexible liquidtight steel conduit designed for a variety of installations requiring motion, vibration and bending. It offers good mechanical and moisture protection to enclosed conductors. Squarelock with Filler 5/16” - 2” Interlock 2-1/2” - 6” Construction The flexible inner core is made from a spiral wound strip of corrosion resistant plating steel. The 1/4 through 2 inch trade sizes are squarelock formed and, with the exception of the 1/4 inch size, contain a nylon cord packing within the convolutions. The larger sizes are constructed with a fully interlocked strip to add strength and to prevent unraveling. A flexible yet durable PVC jacket is extruded over this core creating a liquidtight conduit resistant to most oils, acids and vapors present in industrial environments. Refer to the Conduit — Chemical Resistance Chart beginning on p.158. - Inside Bend Radius in. (mm) Weight kg/30m 1.0 1.0 1.5 2.0 2.5 3.0 3.5 4.5 5.5 8.0 11.0 12.0 17.5 22.5 8 8 9 11 15 24 31 40 53 76 132 156 212 259 (25.4) (25.4) (38.1) (50.8) (63.5) (76.2) (88.9) (114.3) (139.7) (203.2) (279.4) (304.8) (444.5) (571.5) Applications This conduit is used extensively in the machine tool and other industrial environments where flexibility is necessary for installation and maintenance or where vibration and movement must be absorbed. The inherent sunlight resistance of PVC enables this product to be used in outdoor applications. Compatible with standard liquidtight fittings. The construction of this conduit conforms to, and is suitable for use with Sections 16 & 17.7 of the Electrical Standard for Industrial Machinery (ANSI/NFPA-79). Working Temperatures -20°C to 80°C Listing / Certification JIC — manufactured in accordance with the dimensions and specifications as outlined by the Joint Industrial Council Standard for Mass Production Equipment and Machine Tools. Standard Colours Machine tool grey and black. Other colours available upon request. Part numbers listed designate grey jacket. 129 T&B Conduit Fittings Liquatite® Flexible Conduit — Steel JIC Type LOR Type LOR This product is offered as a non-UL oilresistant conduit that incorporates a high quality PVC jacket. Trade Size (in.) Cat. No. Carton Content* (m) 3/8 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 5 6 LOR038-30 LOR050-50 LOR075-30 LOR100-30 LOR125-15 LOR150-15 LOR200-15 LOR250-8 LOR300-8 LOR350-8 LOR400-8 LOR500-8 LOR600-8 30 30 30 30 15 15 15 8 8 8 8 8 8 Cat. No. LOR038-150 LOR050-150 LOR075-150 LOR100-120 LOR125-60 - Carton Content* (m) 150 150 150 120 60 - Carton Content* (m) Cat. No. LOR038-300 LOR050-300 LOR075-300 - 300 300 300 - Inside Bend Radius in. (mm) 2.0 2.5 3.0 4.0 4.5 5.5 7.0 9.5 11.5 13.0 14.0 20.0 22.5 (50.8) (63.5) (76.2) (101.6) (114.3) (139.7) (177.8) (241.3) (292.1) (330.2) (356.6) (508.0) (571.5) Wt. Kg/30m 19 11 15 24 31 40 53 76 118 132 156 221 259 See Chart on p.155 for dimensions and tolerances. * See p.155 for label and packaging detail. Applications The LOR is ideally used in situations where a UL listing or CSA certification is not a factor but where a flexible conduit must withstand exposure to many harsh chemicals, oils, UV, etc. This conduit conforms to Section 17.7 of the Electrical Standard for Industrial Machinery. (ANSI/NFPA-79) Compatible with Standard Liquidtight Fittings. Working Temperatures -20°C to 60°C intermitting to 90°C Standard Colours Machine tool grey and black. Other colours available upon request. Part numbers listed designate grey jacket. Note For a UL listed version, consult your Regional Sales Office for Type LA/LOR. Type EF Type EF This flexible liquidtight conduit is a competitive grade version of our Type LT. It conforms to both the JIC standards for dimensions and general construction, and to Section 17.7 of the Electrical Standard for Industrial Machinery (ANSI/NFPA-79). Trade Size (in.) Cat. No. 3/8 1/2 3/4 1 1-1/4 1-1/2 2 EF038-30 EF050-30 EF075-30 EF100-30 EF125-15 EF150-15 EF200-15 Carton Content* (m) 30 30 30 30 15 15 15 Cat. No. EF038-150 EF050-150 EF075-150 EF100-120 EF125-75 EF150-45 EF200-30 Carton Content* (m) Cat. No. Carton Content* (m) 150 150 150 120 75 45 30 EF038-300 EF050-300 EF075-300 - 300 300 300 - Inside Bend Radius in. (mm) 1.5 2.0 3.0 3.0 3.5 4.5 5.5 See Chart on p.155 for dimensions and tolerances. * See p.155 for label and packaging detail. (38.1) (50.8) (63.5) (76.2) (88.9) (114.3) (139.7) Wt. kg/30m 9 11 14 20 25 41 5 Construction The flexible inner core is constructed from a helically formed strip of corrosion resistant steel. A liquidtight PVC jacket is then extruded over the core. Applications General installations requiring some movement and protection for contained conductors. Forms a liquidtight system when installed with standard fittings for use indoors or out. Working Temperatures -20°C to 80°C Standard Colour Machine tool grey 130 T&B Conduit Fittings Liquatite® Flexible Conduit — Steel Type LA Trade Size (in.) 3/8 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 Cat. No. Carton Content* (m) LA038-30 LA050-30 LA075-30 LA100-30 LA125-15 LA150-15 LA200-15 LA250-8 LA300-8 LA350-8 LA400-8 30 30 30 30 15 15 15 8 8 8 8 Cat. No. Reel Content* (m) Cat. No. Reel Content* (m) LA038-150 LA050-150 LA075-150 LA100-120 LA125-60 LA150-45 LA200-30 LA250-80 LA300-50 LA350-50 LA400-30 150 150 150 120 60 45 30 80 50 50 30 LA038-300 LA050-300 LA075-300 - 300 300 300 - Inside Bend Radius in. (mm) 2.0 3.0 4.2 5.5 7.0 4.5 6.0 8.0 10.0 11.0 12.0 (50.8) (76.2) (106.7) (139.7) (177.8) (114.3) (152.4) (203.2) (254.0) (279.4) (304.8) Weight kg/30m 13 15 24 37 46 47 66 87 114 140 154 See Chart on p.155 for dimensions and tolerances. * See p.155 for label and packaging detail. Squarelock with filler 3 /8” - 1-1/4” Type LA A flexible liquidtight steel conduit which is both listed UL and certified CSA. It offers outstanding protection against wet, oily conditions and is permitted for use in exposed or concealed locations. Construction The flexible inner core is made from a spiral wound strip of heavy gauge, corrosion resistant, hot-dipped galvanized steel. The 3/8 through 1-1/4 inch trade sizes are square lock formed and include an integral bonding strip of copper that is enclosed within the convolutions throughout its entire length. The 1-1/2 through 4 inch trade sizes are designed with a fully interlocked strip. The liquidtight jacketing material is of a high quality, rugged, flame retardant flexible PVC compound which resists oils, mild acids and exposure to sunlight. For further information, refer to the Conduit — Chemical Resistance chart beginning on p. 158. Interlock 1-1/2” - 4” Applications This conduit is intended for installation with Rule 12-1300 of Canadian Electrical Code (CEC) Part I 2009. The use of a separate bonding conductor is mandatory in accordance with CEC Rule 12-1306 for Ordinary Locations. The use of Liquidtight Flexible Conduit with sign and Outline Lighting are in accordance with CEC Rule 34-400 (2). - Listed and marked for direct burial and in poured concrete. - For containment of 600-volt and lower potential circuits - Sunlight resistant Working Temperatures -20°C to 60°C intermitting to 90°C Listing / Certification Listed. Conforms to UL Standard ANSI/UL-360 for Liquidtight Flexible Steel Conduit. Certified. Conforms to CSA 22.2 No. 56 for use per CEC C22.1 Section 12-1300. Standard Colours Machine tool grey, and black. Other colours available upon request. Blue is commonly used for computer room installations. See TYPE CBLA on p.132. 131 T&B Conduit Fittings Liquatite® Flexible Conduit — Steel Type CBLA — Computer Blue Trade Size (in.) 3/8 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 Cat. No. CBLA038-30 CBLA050-30 CBLA075-30 CBLA100-30 CBLA125-15 CBLA150-15 CBLA200-15 CBLA250-8 CBLA300-8 CBLA350-8 CBLA400-8 Carton Content* (m) 30 30 30 30 15 15 15 8 8 8 8 Cat. No. CBLA038-150 CBLA050-150 CBLA075-150 CBLA100-120 CBLA125-60 CBLA150-45 CBLA200-30 CBLA250-80 CBLA300-50 CBLA350-50 CBLA400-30 Reel Content* (m) 150 150 150 120 60 45 30 80 50 50 30 Cat. No. CBLA038-300 CBLA050-300 CBLA075-300 - Reel Content* (m) 300 300 300 - Inside Bend Radius in. (mm) 2.0 3.0 4.2 5.5 7.0 4.5 6.0 8.0 10.0 11.0 12.0 (50.8) (76.2) (106.7) (139.7) (177.8) (114.3) (152.4) (203.2) (254.0) (279.4) (304.8) Wt. kg/30m 13 15 24 37 46 47 66 87 114 140 154 See Chart on p.155 for dimensions and tolerances. * See p.155 for label and packaging detail. Type CBLA Computer Blue LA is a liquidtight flexible steel conduit commonly used for computer room installations. The blue jacket colour easily identifies circuitry for computer power wiring. Construction CBLA has a flexible inner core made from a spiral wound strip of heavy gauge, hot-dipped galvanized steel. The 3/8 through 1-1/4 inch trade sizes contain an integral bonding strip of copper. The 1-1/2 and larger sizes are designed with a fully interlocked strip. The jacketing material is a rugged flame retardant flexible blue PVC. For installations which do not allow the use of PVC, see TYPE ZHLA on P. 139. 132 Applications Listed and marked for direct burial and in poured concrete. Working Temperatures -20°C to 60°C Listing / Certification Listed. Conforms to UL Standard ANSI/UL-360 for Liquidtight Flexible Steel Conduit. Certified. Conforms to CSA 22.2 No. 56 for use per CEC C22.1 Section 12-1300. T&B Conduit Fittings Liquatite® Flexible Conduit — Steel Type CSA Trade Size (in.) 3/8 1/2 3/4 3/4 1 1-1/4 1-1/2 2 2-1/2 3 4 Cat. No. Carton Content* (m) CSA038-30 CSA050-30 CSA075-15 CSA075-30 CSA100-30 CSA125-15 CSA150-15 CSA200-15 CSA250-8 CSA300-8 CSA400-8 30 30 15 30 30 15 15 15 8 8 8 Cat. No. Reel Content* (m) Cat. No. Reel Content* (m) CSA038-150 CSA050-150 CSA075-150 CSA100-120 CSA125-60 CSA150-45 CSA200-30 - 150 150 150 60 45 30 - CSA038-300 CSA050-300 CSA075-300 - 300 300 300 - Inside Bend Radius in. (mm) Weight kg/30m 2.0 3.0 (50.8) (76.2) 11 16 4.0 5.0 6.2 4.5 6.0 8.0 10.0 12.0 (101.6) (127.0) (157.5) (114.3) (152.4) (203.2) (254.0) (304.8) 24 27 39 55 70 93 120 181 See Chart on p.155 for dimensions and tolerances. * See p.155 for label and packaging detail. Type CSA This flexible liquidtight steel conduit is certified CSA. Its design and function is similar to that of type LA except that it cannot be used as a ground return path per CEC. It also offers a wider operating temperature range. Construction The flexible inner core is made from a spiral wound strip of heavy gauge, corrosion resistant, hot-dipped galvanized steel. The 3/8 through 1-1/4 inch trade sizes are cord packed. The durable PVC flame retardant jacket is designed for good flexibility and impact resistance at low temperatures. Applications This conduit is intended for use according to CEC as described in section 121300 for dry, damp or wet locations where flexibility is necessary. This conduit is intended for installation with Rule 12-1300 of Canadian Electrical Code (CEC) Part I 2009. The use of a separate bonding conductor is mandatory in accordance with CEC Rule 12-1306 for Ordinary Locations. The use of Liquidtight Flexible Conduit with sign and Outline Lighting are in accordance with CEC Rule 34-400 (2). Working Temperatures -40°C to 75°C Listing / Certification Certified. Conforms to CSA Standard C22.2, No. 56. Flame Test Rating FT-4 per CSA Standard C22.2, No. 0.3. Standard Colour Black 133 T&B Conduit Fittings Liquatite® Flexible Conduit — Steel Type ATLA — All Temperature Trade Size (in.) 3/8 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 Cat. No. Carton Content* (m) ATLA038-30 ATLA050-30 ATLA075-30 ATLA100-30 ATLA125-15 ATLA150-15 ATLA200-15 ATLA250-8** ATLA300-8** ATLA350-8** ATLA400-8** 30 30 30 30 15 15 15 8 8 8 8 Cat. No. Reel Content* (m) Cat. No. Reel Content* (m) ATLA038-150 ATLA050-150 ATLA075-150 ATLA100-120 ATLA125-60 ATLA150-45 ATLA200-30 - 150 150 150 120 60 45 30 - ATLA038-300 ATLA050-300 ATLA075-300 - 300 300 300 - Inside Bend Radius in. (mm) 2.0 3.0 4.2 5.5 7.0 4.5 6.0 8.0 10.0 11.0 12.0 (50.8) (76.2) (106.7) (139.7) (177.8) (114.3) (152.4) (203.2) (254.0) (279.4) (304.8) Wt. kg/30m 13 15 24 37 46 47 66 87 114 140 154 See Chart on p.155 for dimensions and tolerances. * See p.155 for label and packaging detail. ** Not CSA Certified. Type ATLA A liquidtight flexible steel conduit designed specifically for extreme hot or cold environments. The flexible inner core is identical to that found in Type LA. The specially formulated PVC jacket remains flexible at low temperatures and resists ageing at elevated temperatures. It is listed UL and certified CSA. Construction ATLA has a flexible inner core made from a spiral wound strip of heavy gauge, hot-dipped galvanized steel. The 3/8 through 1-1/4 inch trade sizes contain an integral bonding strip of copper. The 1-1/2 and larger sizes are designed with a fully interlocked strip. The jacketing material is a rugged flame retardant flexible PVC resistant to weathering, UV, oils and many chemicals. Refer to the Conduit — Chemical Resistance Guide beginning on p.158. Applications Designed to be used with high temperature machine tool wiring. Ideal for outdoor installations in cold climates. This conduit is intended for installation with Rule 12-1300 of Canadian Electrical Code (CEC) Part I 2002. The use of a separate bonding conductor is mandatory in accordance with CEC Rule 12-1306 for Ordinary Locations. The use of Liquidtight Flexible Conduit with sign and Outline Lighting are in accordance with CEC Rule 34-400 (2). - Listed and marked for direct burial and in poured concrete. - For containment of 600-volt and lower potential circuits. Working Temperatures -55°C to 105°C Air / 60°C Wet / 70°C Oil Listing / Certification Listed. Conforms to UL Standard ANSI/ UL-360 for Liquidtight Flexible Steel Conduit. Certified. Conforms to CSA 22.2 No. 56 for use per the CEC C22.1 Section 12-1300. Conforms to the requirements of Section 16 & 17.7 of the ANSI/NFPA-79 Electrical Standard for Industrial Machinery. Standard Colour Machine tool grey 134 T&B Conduit Fittings Liquatite® Flexible Conduit — Steel Type AT — High and Low Temperatures Type AT A flexible steel conduit which uses a jacketing material specifically designed for hot or cold environments. Trade Size (in.) 3/8 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 5 6 Cat. No. Carton Content* (m) Cat. No. Carton Content* (m) AT038-30 AT050-30 AT075-30 AT100-30 AT125-15 AT150-15 AT200-15 AT250-8 AT300-8 AT350-8 AT400-8 AT500-8 AT600-8 30 30 30 30 15 15 15 8 8 8 8 8 8 AT038-150 AT050-150 AT075-150 AT100-120 AT125-60 AT150-45 AT200-30 - 150 150 150 120 60 45 30 - Cat. No. AT038-300 AT050-300 AT075-300 - Carton Content* (m) 300 300 300 - Inside Bend radius in. (mm) 1.5 2.0 2.5 3.0 3.5 4.5 5.5 8.0 10.0 11.0 12.0 17.5 22.5 (38.1) (50.8) (63.5) (76.2) (88.9) (114.3) (139.7) (203.2) (254.0) (279.4) (304.8) (444.5) (571.5) Wt. kg/30m 9 11 15 24 31 40 53 76 118 132 156 221 259 See Chart on p.155 for dimensions and tolerances. * See p.155 for label and packaging detail. Applications Type AT is well suited for exposure to extreme climatic conditions. It is also widely used on industrial process equipment such as annealing ovens, lumber kilns, foundries and refrigeration, etc. The construction of this conduit conforms to, and is suitable for use with Sections 16 & 17.7 of the Electrical Standard for Industrial Machinery (ANSI/NFPA-79). Uses standard liquidtight fittings. Working Temperatures -55°C to 105°C intermitting to 120°C Standard Colour Machine tool grey Note For a UL listed and CSA certified version, see TYPE ATLA on p. 134. Type ATX — Extreme Temperature Type ATX A conduit designed to withstand an extreme temperature range. Trade Size (in.) 3/8 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 4 Cat. No. Carton Content* (m) Cat. No. Carton Content* (m) ATX038-30 ATX050-30 ATX075-30 ATX100-30 ATX125-15 ATX150-15 ATX200-15 ATX250-8 ATX300-8 ATX400-8 30 30 30 30 15 15 15 8 8 8 ATX038-150 ATX050-150 ATX075-150 ATX100-120 ATX125-60 ATX150-45 ATX200-30 - 150 150 150 120 60 45 30 - Cat. No. ATX038-300 ATX050-300 ATX075-300 - Carton Content* (m) 300 300 300 - Inside Bend radius in. (mm) 1.5 2.0 2.5 3.0 3.5 4.5 5.5 8.0 10.0 12.0 See Chart on p.155 for dimensions and tolerances. * See p.155 for label and packaging detail. *New High Temperature Fittings available. Refer to p. 91. Wt. kg/30m (38.1) 10 (50.8) 12 (63.5) 18 (76.2) 25 (88.9) 33 (114.3) 47 (139.7) 62 (203.2) 85 (254.0) 111 (304.8) 151 Construction Utilizes the flexibility of our standard LT core, coupled with the advantage of a thermoplastic rubber jacket that is virtually unaffected by temperature extremes and contains no halogens. The material has a UL 94-HB flammability rating. Applications Used in situations where there are concerns of resistance to temperature exposure. These include heavy outdoor equipment, boilers and furnaces, etc. Refer to the Conduit — Chemical Resistance Guide beginning on p.158. Working Temperatures -60°C to 150°C intermitting to 165°C Standard Colour Black 135 T&B Conduit Fittings Liquatite® Flexible Conduit — Aluminum Type ALT — Lightweight Aluminum Trade Size (in.) Cat. No. Carton Content* (m) 3/8 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 5 6 ALT038-30 ALT050-30 ALT075-30 ALT100-30 ALT125-15 ALT150-15 ALT200-15 ALT250-8 ALT300-8 ALT350-8 ALT400-8 ALT500-8 ALT600-8 30 30 30 30 15 15 15 8 8 8 8 8 8 Cat No. ALT038-150 ALT050-150 ALT075-150 ALT100-120 ALT125-60 ALT150-45 ALT200-30 - Reel Content* (m) 150 150 150 120 60 45 30 - Cat No. Reel Content* (m) ALT038-300 ALT050-300 ALT075-300 - 300 300 300 - Inside Bend Radius in. (mm) 2.0 2.5 3.0 4.0 4.5 5.5 7.0 9.5 11.5 13.0 14.0 20.0 22.5 (50.8) (63.5) (76.2) (101.6) (114.3) (139.7) (177.8) (241.3) (292.1) (330.2) (355.6) (508.0) (571.5) Wt. kg/30m 5 7 9 13 18 25 33 47 60 74 81 114 143 See Chart on p.155 for dimensions and tolerances. * See p.155 for label and packaging detail. Type ALT This version of Liquidtight Flexible Conduit is similar to our standard type LT but weighs considerably less due to the use of an aluminum inner core instead of steel. Applications Type ALT is often used where weight or corrosive atmospheres are an issue. When comparing identical trade sizes, Type ALT weighs approximately 37% less than type LT. Uses standard liquidtight fittings. 136 Working Temperatures -20°C to 80°C Standard Colours Machine tool grey and black. Other colours available upon request. Part numbers listed designate grey jacket. T&B Conduit Fittings Liquatite® Flexible Conduit — Steel Type CEA — Non-Halogen, Low Smoke, Flame Retardant Type CEA This liquidtight flexible steel conduit is designed for applications where safety concerns exist regarding a material’s reaction in a fire situation. Trade Size 3/8 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 4 5 6 Cat. No. CEA038-30 CEA050-30 CEA075-30 CEA100-30 CEA125-15 CEA150-15 CEA200-15 CEA250-8 CEA300-8 CEA400-8 CEA500-8** CEA600-8** Carton Content* (m) 30 30 30 30 15 15 15 8 8 8 8 8 Cat. No. Carton Content* (m) Minimum Jacket Thickness CEA038-300 CEA050-300 CEA075-150 CEA100-120 CEA125-60 CEA150-45 CEA200-30 - 300 300 150 120 60 45 30 - 0.8 0.8 0.9 0.9 0.9 1.0 1.0 1.3 1.3 1.5 2.5 2.5 Inside Bend Radius in. (mm) 1.5 2.0 2.5 3.0 3.5 4.5 5.5 8.0 10.0 12.0 17.5 22.5 (38.1) (50.8) (63.5) (76.2) (88.9) (114.3) (139.7) (203.2) (254.0) (304.8) (444.5) (635.0) Wt. kg/30m 9 11 15 24 31 40 53 76 118 156 212 259 See Chart on p.155 for dimensions and tolerances. * See p.155 for label and packaging detail. **Available on request. Type ACEA also available (liquidtight flexible aluminum conduit). Aluminum core weighs approximately one third less than steel core. Type CEA Combustion & Flammability Properties Combustion & Flammability Properties** Test Value -Vertical Burn (Material) UL94 V-O Rating No Flaming Drips -Vertical Burn (Conduit) UL360 Pass No Flaming Drips -Oxygen Index % D2863 28.5 -Flame Spread Index ASTM E162 4.0 No Flaming Drips -Flame Propagation ASTM C542 (NFPA-130) Pass No Flaming Drips -Smoke Generation (Flaming) ASTM E662 (NFPA 258) Ds 41 @ 1.5 min Ds 94 @ 4.0 min -Smoke Generation (Non-Flaming) ASTM E662 (NFPA 258) Ds 7 @ 1.5 min Ds 45 @ 4.0 min -Toxic Gas Generation -Toxicity Index BOMBARDIER SMP 800-C Pass NES 713 3.9 **Test data is based on controlled laboratory conditions and does not necessarily reflect performance in actual fire conditions. Additional product information available upon request. 137 Construction The flexible inner core of this product is made from a galvanized steel strip. As in type LT, this core contains string packing between the helical convolutions in trade sizes 3/8” through 2”. The specially formulated thermoplastic polyurethane jacket has excellent flame retardant characteristics as well as low smoke and toxicity generation characteristics. Acidic gases such as hydrogen chloride, hydrogen fluoride and hydrogen bromide are virtually eliminated as products of combustion. Applications This product is ideally suited for installation in confined or enclosed areas where construction materials must generate very little smoke, and have a low flame spread as well as low toxic gas emissions in the event of fire. Such applications include mass transit vehicles where CEA is extensively used for wiring harnesses within and under passenger rail cars. Other applications include use in underground subway structures and tunnels. Working Temperatures -40°C to 80°C Standard Colours Grey and black. Other colours available upon request. Part numbers listed designate grey jacket. T&B Conduit Fittings Liquatite® Flexible Conduit— Aluminum Type ACEA — Non-Halogen, Low Smoke, Flame Retardant Type ACEA This liquidtight flexible aluminum conduit is designed for applications where safety concerns exist regarding a material’s reaction in a fire situation. Min. Inside Bend Weight Jacket Thick. Radius Kilogram (mm) (mm) 30 m Length (m) Carton Length (m) Cat. No. Reel Trade Size Type 3/8 ACEA038 0.8 50.8 5 60 ACEA038-30 - - 300 ACEA038-300 - - 1/2 3/4 1 1-1/4 1-1/2 2 ACEA050 ACEA075 ACEA100 ACEA125 ACEA150 ACEA200 0.8 0.9 0.9 0.9 1.0 1.0 63.5 76.2 101.6 114.3 139.7 177.8 7 9 13 18 25 33 30 30 30 15 15 15 ACEA050-30 ACEA075-30 ACEA100-30 ACEA125-15 ACEA150-15 ACEA200-15 30 45 - ACEA075-45 - 300 150 120 75 45 30 ACEA050-300 ACEA075-150 ACEA100-120 ACEA125-75 ACEA150-45 ACEA200-30 - - 2-1/2 3 4 5 6 - - ACEA250 ACEA300 ACEA400 ACEA500 ACEA600 - 1.3 1.3 1.5 2.5 2.5 - 241.3 330.2 355.6 508.0 571.5 47 60 87 114 143 8 8 8 8 8 ACEA250-8 ACEA300-8 ACEA400-8 ** ** - - - - - - Cat. No. See Chart on p.155 for dimensions and tolerances. * See p.155 for label and packaging detail. **Available on request. Type ACEA Combustion & Flammability Properties Combustion & Flammability Properties** Test Value -Vertical Burn (Material) UL94 V-O Rating No Flaming Drips -Vertical Burn (Conduit) UL360 Pass No Flaming Drips -Oxygen Index % D2863 28.5 -Flame Spread Index ASTM E162 9.8 -Flame Propagation ASTM C542 (NFPA-130) Pass No Flaming Drips -Smoke Generation (Flaming) ASTM E662 (NFPA 258) Dm 103 (Corrected) Ds 47 @ 4.0 min -Smoke Generation (Non-Flaming) ASTM E662 (NFPA 258) Dm 91 (Corrected) Ds 5 @ 1.5 min -Toxic Gas Generation SMP 801 Pass -Toxicity Index NES 713 3.9 **Test data is based on controlled laboratory conditions and does not necessarily reflect performance in actual fire conditions. Additional product information available upon request. Length (m) Length (m) Cat. No. Cat. No. Construction The flexible inner core of this product is made from an aluminum strip. As in type CEA, this core contains string packing between the helical convolutions in trade sizes 3/8” through 1-1/4”. The specially formulated thermoplastic polyurethane jacket has excellent flame retardant characteristics as well as low smoke and toxicity generation characteristics. Acidic gases such as hydrogen chloride, hydrogen fluoride and hydrogen bromide are virtually eliminated as products of combustion. Applications This product is ideally suited for installation in confined or enclosed areas where construction materials must generate very little smoke, and have a low flame spread as well as low toxic gas emissions in the event of fire. Such applications include mass transit vehicles where ACEA is extensively used for wiring harnesses within and under passenger rail cars. Other applications include use in underground subway structures and tunnels. Working Temperatures -40°C to 80°C Standard Colours Machine Tool Grey. Other colours available upon request. Note A UL listed version is pending. Consult factory for availability of type ZHLA. 138 T&B Conduit Fittings Liquatite® Flexible Conduit— Steel Type ZHLA — Non-Halogen, Low Smoke, Flame Retardant Trade Size (in.) 3/8 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 Cat. No. Carton Content* (m) ZHLA038-30 ZHLA050-30 ZHLA075-30 ZHLA100-30 ZHLA125-15 ZHLA150-15 ZHLA200-15 ZHLA250-8 ZHLA300-8 ZHLA350-8 ZHLA400-8 30 30 30 30 15 15 15 8 8 8 8 Cat. No. Carton Content* (m) Cat. No. Carton Content* (m) ZHLA038-150 ZHLA050-150 ZHLA075-150 ZHLA100-120 ZHLA125-60 ZHLA150-45 ZHLA200-30 - 150 150 150 120 60 45 30 - ZHLA038-300 ZHLA050-300 ZHLA075-300 - 300 300 300 - Inside Bend Radius in. (mm) 2.0 3.0 4.2 5.5 7.0 4.5 6.0 8.0 10.0 11.0 12.0 (50.8) (76.2) (106.7) (139.7) (177.8) (114.3) (152.4) (203.2) (254.0) (279.4) (304.8) Type ZHLA Non-halogen, low smoke and low flame spread are what makes Type ZHLA a proven choice for applications where limiting toxic combustion materials is an important issue. Since ZHLA is also UL Listed, it is ideal for field installation in confined, public areas such as subways, tunnels, etc. Wt. kg/30m 13 15 24 37 46 47 66 87 114 140 154 See Chart on p.155 for dimensions and tolerances. * See p.155 for label and packaging detail. Type ZHLA Combustion & Flammability Properties Combustion & Flammability Properties** Test Value -Vertical Burn (Material) UL94 V-O Rating No Flaming Drips -Vertical Burn(Conduit) UL360 Pass No Flaming Drips -Oxygen Index % D2863 28.5 -Flame Spread Index ASTM E162 4.0 No Flaming Drips -Flame Propagation ASTM C542 (NFPA-130) Pass No Flaming Drips -Smoke Generation (Flaming) ASTM E662 (NFPA 258) Ds 41 @ 1.5 min Ds 94 @ 4.0 min -Smoke Generation (Non-Flaming) ASTM E662 (NFPA 258) Ds 7 @ 1.5 min Ds 45 @ min -Toxic Gas Generation -Toxicity Index BOMBARDIER SMP 800-C NES 713 Pass 3.9 ** Test data is based on controlled laboratory conditions and does not necessarily reflect performance in actual fire conditions. Additional product information available upon request. Construction ZHLA has a flexible inner core made from a spiral wound strip of heavy gauge, hotdipped galvanized steel. The 3/8 through 1-1/4 inch trade sizes contain an integral bonding strip of copper. The 11/2inch and larger sizes are designed with a fully interlocked strip. The specially formulated thermoplastic black polyurethane jacket has excellent flame resistance and low smoke and toxicity generation characteristics. It is also resistant to ozone, hydrocarbons, moderate chemicals, oils and fuels. Refer to the Conduit — Chemical Resistance Guide beginning on p. 156. Applications There are many situations and areas where PVC is not allowed for electrical construction. The jacketing material used for ZHLA virtually eliminates the release of acidic gases found in PVC products. - Meets the requirements of Bombardier SMP 800-C for Toxic Gas Generation - Meets the requirements of both ASTM E162 for Flame Spread and ASTM E662 for Smoke Generation. - Listed and marked for direct burial and in poured concrete. - For containment of 600-volt and lower potential circuits. - Sunlight resistant Working Temperatures -40°C to 80°C Air / 60°C Wet / 70°C Oil Listing / Certification Listed. Conforms to UL Standard ANSI/ UL-360 for Liquidtight Flexible Steel Conduit. Standard Colour Black 139 T&B Conduit Fittings Liquatite® Flexible Conduit — Shielding an issue. Today’s Original Equipment Manufacturers (OEMs) are finding that, if they wish to ship electrical equipment into the European community, they may need to be in compliance with recently developed CE standards which reduce the allowable amount of EMI/RFI emissions from electrical apparatus. All three are designed to accept industry standard liquidtight fittings and address the problems of assembly and grounding. Fittings of this type include a grounding ferrule which contacts the internal metallic material of Thomas & Betts offers three types of flexible liquidtight conduits designed for wiring applications requiring shielding effectiveness from Electro-Magnetic and Radio Frequency Interference (EMI/RFI). This series of shielding conduits consists of three configurations: Type LAS, Type EMS and Type EMSP. These conduits are used to protect sensitive electronic circuits such as communications, radar, and data transmission from outside interference or “noise”. The reverse situation is also 1 MHz 127 126 126 110 EMSP EMS LAS LA 10 MHz 130 122 98 80 100 MHz 136 131 75 53 450 MHz 116 98 76 63 ATTENUATION (dB) Shielding Effectiveness the conduit and the fitting body. This produces a direct shield-to-drain or ground, simply by tightening the fitting. The graph below depicts the shielding effectiveness (attenuation in dBs) of all three types. The dotted line shows a comparison to standard unshielded liquidtight flexible conduit, Type LA. The spectrum of test frequency is from 1 MHz to 10 MHz Electric Field, to 100 MHz to 1 GHz (1000 MHz) Planewave Field. Tests were performed per MIL-STD-285 on 1/2 inch trade size conduit. 1 GHz 118 97 66 51 Type LAS Trade Size (in.) 3/8 1/2 3/4 1 Cat. No. Carton Content* (m) Cat. No. Carton Content* (m) LAS038-30 LAS050-30 LAS075-30 LAS100-30 30 30 30 30 LAS038-150 LAS050-150 LAS075-150 LAS100-120 150 150 150 120 Inside Bend Radius in. (mm) 2.0 3.0 4.2 5.5 (50.8) (76.2) (106.7) (139.7) See Chart on p.155 for dimensions and tolerances. * See p.155 for label and packaging detail. Type LAS Type LAS is identical to standard UL Listed liquidtight flexible steel conduit but is augmented with a tinned copper shielding braid located over the inner steel core and under its protective PVC jacket. The braid offers a minimum of 90% coverage resulting in a shielding effectiveness range from 126 dB @ 1 MHz to 66 dB @ 1 GHz. Wt. kg/30m 13 15 24 37 Applications PVC jacket is resistant to a wide variety of oils, acids, alkalines and ultraviolet light. Working Temperatures -20°C to 60°C Listing / Certifications Listed. Conforms to UL360 for liquidtight flexible steel conduit. Standard Colours Black. Other colours and jacketing materials available. Consult your Regional Sales Office for details. 140 T&B Conduit Fittings Liquatite® Flexible Conduit — Shielding Type EMS Type EMS Type EMS has an inner core that is made from a fully interlocked bronze strip. Even though it does not contain a braided shield, it offers a shielding effectiveness from 126 dB @ 1 MHz to nearly 100 dB @ 1 GHz. Trade Size (in.) 3/8 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 4 Cat. No. EMS038-30 EMS050-30 EMS075-30 EMS100-30 EMS125-15 EMS150-15 EMS200-15 EMS250-8 EMS300-8 EMS400-8 Carton Content* (m) Cat. No. Carton Content* (m) 30 30 30 30 15 15 15 8 8 8 EMS038-150 EMS050-150 EMS075-150 EMS100-120 EMS125-60 EMS150-45 EMS200-30 - 150 150 150 120 60 45 30 - Inside Bend Radius in. (mm) 3.0 3.0 4.0 4.0 4.5 7.0 9.5 12.0 13.5 17.0 (76.2) (76.2) (101.6) (101.6) (114.3) (177.8) (241.3) (304.8) (342.9) (431.8) Wt. kg/30m 12 16 20 39 46 64 82 105 145 176 Working Temperatures -55°C to 105°C Standard Colour Grey. Other colours and jacketing materials available. Consult your Regional Sales Office for details. See Chart on p.155 for dimensions and tolerances. * See p.155 for label and packaging detail. INTERLOCK Type EMSP Type EMSP Type EMSP is a hybrid of LAS and EMS. It utilizes the same bronze core and PVC jacket as EMS but gets further screening protection from a tinned copper braid as found in the LAS product. Its range of shielding effectiveness is from 126 dB @ 1 MHz to 120 dB @ 1 GHz. Trade Size (in.) 3/8 1/2 3/4 1 Cat. No. Carton Content* (m) EMSP038-30 EMSP050-30 EMSP075-30 EMSP100-30 30 30 30 30 Cat. No. Carton Content* (m) EMSP038-150 EMSP050-150 EMSP075-150 EMSP100-120 150 150 150 120 Inside Bend Radius in. (mm) 3.0 3.0 4.0 4.0 (76.2) (76.2) (101.6) (101.6) See Chart on p.155 for dimensions and tolerances. * See p.155 for label and packaging detail. 141 Wt. kg/30m 12 16 20 39 T&B Conduit Fittings Liquatite® Flexible Conduit — Steel Type BR Type BR This non-jacketed flexible steel conduit has many universal wiring applications. It is often referred to as “Greenfield” or “Reduced Wall Flex”. Construction Type BR is formed from high corrosion resistant hot-dipped galvanized steel. Its profile and helical shape allow it to withstand impact and crushing forces. Applications General Use: In accordance with CEC Rule 12-1002 (1) the flexible metal conduit is permitted in or on buildings of either combustible or noncombustible constructions. Restriction and Exception: CEC Rule 12-1004 (a) states:“12 (3/8) trade size flexible metal conduit shall be permitted to be used for runs of not more than 1.5 m (5 ft) for the connection of equipment.” Trade Size (in.) Cat. No. 3/8 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 BR038* BR050 BR075 BR100 BR125 BR150 BR200 BR250 BR300 BR350 BR400 and CEC Rule 12-1004 (b) states:“12 (3/8) trade size liquidtight flexible conduit may be used as permitted by this code.” Securements with straps: CEC Rule 12-1010 (3) states: “When flexible metal conduit is installed, it shall be secured at intervals not exceeding 1.5 m (5 ft) and within 300 mm (12 in.) on each side of every outlet box or fitting except where flexible metal conduit is fished and except for lengths of not over 900 mm (3 ft) at terminals where flexibility is necessary.” Conductor fill: CEC Rule 12-1014 defines the maximum number of conductor, the CEC Tables 6 provides the maximum number of conductors of one size in trade sizes of conduit,CEC Table 8 provides the maximum allowable per cent conduit fill, and CEC Table 9 provides the cross-sectional areas of conduit. Specific Use and applications: Elevators, Hoistways, in accordance with CEC Rules 38-021 (1) (a) (1) and 38-0221 (1) Inner Diameter Min. Max. in. (mm) in. (mm) 0.375 (9.5) 0.625 (15.9) 0.812 (20.6) 1.000 (25.4) 1.250 (31.8) 1.500 (38.1) 2.000 (50.8) 2.500 (63.5) 3.000 (76.2) 3.500 (88.9) 4.000 (101.6) 0.393 0.645 0.835 1.040 1.300 1.575 2.080 2.700 3.200 - (10.0) (16.4) (21.2) (26.4) (33.0) (40.0) (52.8) (68.6) (81.3) - (a) (iv) Elevators, Cars, in accordance with CEC Rules 38-021 (1) (b) (v) Elevators, Within Machine Rooms, Control Rooms and Machinery Spaces and Control Spaces, in accordance with CEC Rule 38-021 (1) (c) (1) Elevators, Conterweights, in accordance with CEC Rule 38-021 (1) (d) EScalators, in accordance with CEC Rule 38-021 (2) Lifts for persons with physical disabilities, in accordance with CEC Rule 38-021 (3) Theater installation, in accordance with CEC Rule 44-102 (1) Listing/ Certification Listed. (sizes 3/8 through 3 in.). Conforms to UL Standard ANSI/UL-1 for Flexible Metal Conduit. Certified. ( 3/8 inch size only). Conforms to CSA 22.2 No. 56 for use per CEC C22.1 Section 12-1000. Meets Federal Specification WW-C-566c Type II Flexible metal conduit is also permitted for use on industrial machinery where temperatures exceed the limits of liquidtight flexible conduit. (ANSI/NFPA-79) Section 16.3.4 (exception) and Section 17.9. Outer Diameter Min. Max. in. (mm) in. (mm) 0.560 (14.2) 0.860 (21.8) 1.045 (26.5) 1.300 (33.0) 1.550 (39.4) 1.850 (47.0) 2.350 (59.7) 2.860 (72.6) 3.360 (85.3) 3.860 (98.0) 4.360 (110.7) 0.610 (15.5) 0.920 (23.4) 1.105 (28.1) 1.380 (35.1) 1.630 (41.4) 1.950 (49.5) 2.454 (62.3) 3.060 (77.7) 3.560 (90.4) 4.060 (103.1) 4.560 (115.8) Types BR and ABR Strip Profile * CSA Certified. Min.Trade Coil Size Content (in.) Cat. No. (m) 3/8 BR038-8* 8 1/2 BR050-8 8 3/4 BR075-8 8 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 - Coil Content Cat. No. (m) BR038-15* BR050-15 BR075-15 BR100-15 BR125-15 BR150-8 BR200-8 BR250-8 BR300-8 BR350-8 BR400-8 15 15 15 15 15 8 8 8 8 8 8 Cat. No. Coil Content (m) BR038-30* BR050-30 BR075-30 - 30 30 30 - Cat. No. Coil Content (m) BR038-75* 75 - * CSA Certified. 142 Cat. No. Coil Content (m) BR038-300* BR050-300 BR075-150 BR100-120 BR125-120 BR150-90 BR200-45 - 300 300 150 120 120 90 45 - Inside Bend Radius in. (mm) 2.0 3.0 4.0 5.0 6.2 7.5 10.0 12.5 15.0 17.5 20.0 (50.8) (76.2) (101.6) (127.0) (157.5) (190.5) (254.0) (317.5) (381.0) (444.5) (508.0) Wt. kg/30m 18 13 15 24 29 36 45 68 82 100 122 T&B Conduit Fittings Liquatite® Flexible Conduit — Aluminum Type ABR Trade Size (in.) Coil Length Cat. No. (m) Cat. No. Coil Length (m) Cat. No. Coil Length (m) ABR716-30 30 3/8 ABR038-8† 8 ABR038-15† 15 ABR038-30† 30 1/2 ABR050-8 8 ABR050-15 15 ABR050-30 30 3/4 ABR075-8 8 ABR075-15 15 ABR075-30 30 1 ABR100-15 15 1-1/4 ABR125-15 15 1-1/2 ABR150-8 8 2 ABR200-8 8 2-1/2 ABR250-8 8 3 ABR300-8 8 3-1/2 ABR350-8 8 4 ABR400-8 8 See Chart on p.155 for dimensions and tolerances. * See p.155 for label and packaging detail. Note: Dimensions and Bend Radii are identical to Type BR, p. † CSA Certified. Type ABR This non-jacketed flexible aluminum conduit has many universal wiring applications. It is often referred to as “Greenfield” or “Reduced Wall Flex”. Construction Type ABR is formed using a high strength aluminum alloy strip. The result is a conduit with similar characteristics to those of type BR steel but at about 1/3 the weight. Reel Content* (m) Cat. No. ABR716-300 ABR038-300† ABR050-300 ABR075-150 ABR100-120 ABR125-120 ABR150-90 ABR200-45 300 300 300 150 120 120 90 45 - Wt. kg/30m 7.0 9.5 13.5 24.0 31.0 47.0 67.0 92.0 107.0 122.0 142.0 140. Applications General Use: In accordance with CEC Rule 12-1002 (1) the flexible metal conduit is permitted in or on buildings of either combustible or noncombustible constructions. Restriction and Exception: CEC Rule 12-1004 (a) states:“12 (3/8) trade size flexible metal conduit shall be permitted to be used for runs of not more than 1.5 m (5 ft) for the connection of equipment.” and CEC Rule 12-1004 (b) states:“12 (3/8) trade size liquidtight flexible conduit may be used as permitted by this code.” Securements with straps: CEC Rule 12-1010 (3) states: “When flexible metal conduit is installed, it shall be secured at intervals not exceeding 1.5 m (5 ft) and within 300 mm (12 in.) on each side of every outlet box or fitting except where flexible metal conduit is fished and except for lengths of not over 900 mm (3 ft) at terminals where flexibility is necessary.” Conductor fill: CEC Rule 12-1014 defines the maximum number of conductor, the CEC Tables 6 provides the maximum number of conductors of one size in trade sizes of conduit, CEC Table 8 provides the maximum allowable per cent conduit fill, and CEC Table 9 provides the crosssectional areas of conduit. Applications: refer to Type BR, p. 142. Listing/ Certification Listed. (sizes 3/8 through 3 in.). Conforms to UL Standard ANSI/UL-1 for Flexible Metal Conduit. Certified. (3/8 inch size only). Conforms to CSA 22.2 No. 56 for use per CEC C22.1 Section 12-1300. Meets Federal Specification WW-C-566c Type II Type ABRH TYPE - ABRH This non-jacketed flexible aluminum conduit has many universal wiring applications. Trade Size CSA Metric Desig. 3/8 7/16 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 4 12 14 16 21 27 35 41 53 63 78 103 T&B Type ABRH038 ABRH716 ABRH050 ABRH075 ABRH100 ABRH125 ABRH150 ABRH200 ABRH250 ABRH300 ABRH400 Internal Diameter (in.) Min. Max. 0.375 0.437 0.625 0.812 1.000 1.250 1.500 2.000 2.500 3.000 4.000 0.393 0.457 0.645 0.835 1.040 1.300 1.575 2.080 2.700 3.200 - Outer Diameter (in.) Min. Max. 0.560 0.860 1.045 1.300 1.550 1.850 2.350 2.860 3.360 4.360 0.610 0.675 0.920 1.105 1.380 1.630 1.950 2.454 3.060 3.560 4.560 Inside Bend Radius WT. Lbs. per 100 Ft. 2 2.25 3 4 5 6.2 7.5 10 12.5 15 20 7 8 16 18 35 43 55 73 90 107 142 143 Coil Lenght Mtr. 30, 150, 300 30, 150, 300 30, 150, 300 30, 150, 300 15, 120 15, 120 8, 15, 30 8, 15 8, 15 8, 15 8, 15 Construction Type ABRH is formed from a heavy gauge aluminum strip. Its profile and helical shape allow it to withstand substantial impact and crushing forces. Applications This conduit is intended as a metal raceway for wires and cable where CSA Certification is required. Suitable for use with connectors intended for “FMC (Flexible Metal Conduit). Certified File # LL 18858 Conforms to CSA 22.2 No. 56 for use per the Canadian Electrical Code C22.1 Section 12-1300. T&B Conduit Fittings Liquatite® Flexible Conduit — Steel Type SL Inside Diameter Coil Trade Size (in.) (mm) 5/16 3/8 1/2 3/4 1 - 16 20 25 32 Content Cat. No. Min. (m) in. SL316-75 SL140-75 SL516-75 SL380-75 SL716-75 SL038-75 SL916-45 SL050-45 SL050M-45 SL340-45 SL075-30 SL100-15 SL100M-15 75 75 75 75 75 75 45 45 45 45 30 15 15 0.172 0.235 0.297 0.360 0.422 0.492 0.547 0.622 0.650 0.735 0.827 1.041 1.102 Outside Diameter Min. (mm) Max. (mm) (4.35) (5.97) (7.54) (9.14) (10.72) (12.50) (13.89) (15.80) (16.51) (18.67) (21.00) (26.44) (27.99) in. 0.202 0.265 0.327 0.390 0.452 0.512 0.577 0.642 0.670 0.765 0.847 1.066 1.122 (5.13) (6.73) (8.31) (9.91) (11.48) (13.00) (14.66) (16.31) (17.01) (19.43) (21.51) (27.07) (28.50) Min. Inside Max. in. (mm) 0.280 0.328 0.391 0.485 0.547 0.617 0.672 0.747 0.775 0.865 0.957 1.181 1.242 (7.11) (8.33) (9.93) (12.32) (13.89) (15.67) (17.07) (18.97) (19.69) (21.97) (24.31) (30.00) (31.55) Type SL This “extra-flexible” product, available in the smaller diameters, is designed for tightspot installation and where continuous flexing is required of a steel wound hose. in. 0.310 0.358 0.421 0.515 0.577 0.637 0.702 0.767 0.795 0.895 0.977 1.206 1.262 Bend Radius (mm) (in) Wt. (mm) kg/30m (7.87) (9.09) (10.69) (13.08) (14.66) (16.18) (17.83) (19.48) (20.19) (22.73) (24.82) (30.63) (32.05) 0.75 0.75 0.75 1.00 1.00 1.00 1.25 1.50 1.50 1.50 2.00 2.00 2.00 (19.5) (19.5) (19.5) (25.4) (25.4) (25.4) (31.8) (38.1) (38.1) (38.1) (50.8) (50.8) (50.8) 2 3 3 4 4 5 5 7 7 8 8 9 - Applications Offers good mechanical protection to wiring in a variety of O.E.M. applications. Construction Type SL is helically wound from a formed strip of Electro-Galvanized steel. It is sized to be used with a variety of set-screw and clamp type fittings. Squarelock Type USL Type USL This extra-flexible steel conduit is recognized UL and CSA for use within listed and certified assemblies. Cat. No. USL516 USL380 USL716 USL120 USL916 Inner Dia. Min. Max. in. (mm) in. (mm) 0.297(7.54) 0.360(9.14) 0.422(10.7) 0.485(12.3) 0.557(14.1) 0.327(8.30) 0.390(9.91) 0.452(11.48) 0.515(13.08) 0.577(14.65) Outer Dia. Min. Max. in. (mm) in. (mm) 0.457(11.60) 0.520(13.20) 0.582(14.78) 0.645(15.86) 0.707(17.96) 0.487(12.37) 0.550(13.97) 0.612(15.54) 0.675(17.15) 0.737(18.72) Coil Contents Cat. No. (m) USL516-75 USL380-75 USL716-75 USL120-75 USL916-75 75 75 75 75 75 Min. Inside Bend Radius Wt. in. (mm) kg/30m 1.25 1.25 1.50 1.50 1.50 (31.75) (31.75) (38.10) (38.10) (38.10) 5 6 7 8 9 Construction Helically formed from hot-dipped galvanized steel, type USL offers good corrosion resistance and provides excellent mechanical protection to enclosed circuits. Applications This product is intended as a factory installed component of various assemblies. Typical uses include modular office partitions, showcase lighting, range tops and other appliances. Listing / Certification UL Recognized. Squarelock — Type USL 144 T&B Conduit Fittings Liquatite® Flexible Conduit — Steel Type VJC — with PVC Jacket Type VJC Vacuum jacketed steel conduit for high-flex installations. Trade Size (in.) 3/8 1/2 3/4 1 - Outside Dia. Over Jacket Carton Content* (m) Cat. No. VJC038-30 VJC050-30 VJC050M-30 VJC075-30 VJC100-30 VJC100M-30 30 30 30 30 30 30 Min. in. (mm) 0.647 0.777 0.805 0.987 0.221 1.272 in. (16.43) (19.74) (20.45) (25.07) (5.61) (32.31) Max. (mm) 0.677 0.807 0.835 1.017 1.246 1.302 (17.20) (20.50) (21.21) (25.83) (31.65) (33.07) Internal Bend radius Static Dynamic Wt. in. (mm) in. (mm) kg/30m 1.0 1.5 1.5 2.0 3.0 3.0 (25.4) 5 (127.0) (38.1) 6 (152.4) (38.1) 6 (152.4) (51.0) 10 (254.0) (76.0) 10 (254.0) (76.0) 10 (254.0) 5 7 7 9 11 - * Reels available. Consult factory. Construction A unique vacuum extrusion process allows this product to have a thin PVC jacket which does not restrict the great flexibility characteristics of the inner core. The core material is the same as type SL. VJC is designed with dimensions that will accept standard liquidtight fittings. Applications VJC is suitable for use in both static applications where a tight bend diameter is needed and in dynamic use such as machining centers and robotics. Working Temperatures -20°C to 80°C Standard Colour Black. Other colours available upon request. Consult your Regional Sales Office for details. Type UG Type UG A fully-interlocked flexible steel conduit designed for high strength in “tight-spot” installations. Cat. No. UG380-15 UG120-15 UG340-15 UG100-15 UG125-15 UG150-15 UG200-15 UG250-15 UG300-15 Coil Content (m) 15 15 15 15 15 15 15 15 15 Inside diameter Outside DiameterMin. Inside Min. Max. Min. Max. in. (mm) in. (mm) in. (mm) in. (mm) 0.443(11.25) 0.755(19.18) 0.943(23.95) 1.208(30.68) 1.485(37.72) 1.735(44.07) 2.235(56.77) 2.735(69.47) 3.36085.34) 0.473(12.01) 0.785(19.94) 0.973(24.71) 1.238(31.45) 1.515(38.48) 1.765(44.83) 2.265(57.53) 2.765(70.23) 3.390(86.11) 0.563(14.30) 0.875(22.23) 1.063(28.70) 1.328(33.73) 1.578(40.08) 1.843(46.81) 2.390(60.71) 2.937(74.60) 3.438(87.33) Bend Radius Wt. in. (mm) kg/30m 0.593(15.06) 2.5 (63.5) 0.905(22.99) 3.0 (76.2) 1.093(27.76) 3.5 (89.0) 1.358(34.50) 4.5 (114.3) 1.608(40.84) 5.5 (139.7) 1.873(47.57) 6.5 (165.1) 2.420(61.47) 8.5 (216.0) 2.967(75.36) 10.5 (267.0) 3.468(88.09) 13.0 (330.2) Note: Trade sizes do not apply to Type UG. Interlock 145 7 10 14 16 23 27 36 39 48 Construction This conduit is manufactured from a bright tin plated steel strip which is fully interlocked at the edges to produce a strong, yet flexible product. The interlock feature does not allow the conduit to unravel if twisted and permits the conduit to retain it’s shape when bent. This lightweight product is compatible with many set-screw and clamp type fittings. Applications The bright appearance of the finished product lends itself to installations where the conduit may be visible after final assembly. T&B Conduit Fittings Liquatite® Flexible Conduit — Nonmetallic Type LNM-P Trade Size (in.) Cat. No. 3/8 LNMP038-75 1/2 LNMP050-60 3/4 LNMP075-50 1 LNMP100-30 1-1/4 LNMP125-30 1-1/2 LNMP150-15 2 LNMP200-15 Carton Content (m) 75 60 50 30 30 15 15 Cat. No. Reel Content (m) LNMP038-150 LNMP050-150 LNMP075-150 LNMP100-120 LNMP125-60 LNMP150-45 LNMP200-30 150 150 150 120 60 45 30 Cat. No. LNMP038-300 LNMP050-300 Type LNM-P This nonmetallic liquidtight conduit is ideally suited for continuous flexing situations. It is often specified in “Power Track” or cable carrier installations and on industrial robots. It does not contain a metal core which could fatigue from repeated flexing or vibration. Construction LNM-P is of the Layered, Type-A construction which incorporates a smooth seamless inner core of flexible PVC that is bonded to a covering of flexible PVC. Between these layers is a woven nylon mesh for added reinforcement. The PVC material is a high quality flame-retardant compound which resists oils, mild acids and exposure to sunlight. Applications General Use: In accordance with CEC Rule 12-1002 (1) the flexible metal conduit is permitted in or on buildings of either combustible or noncombustible constructions. Restriction and Exception: CEC Rule 12-1004 (a):“12 (3/8) trade size flexible metal conduit shall be permitted to be used for runs of not more than 1.5 m (5 ft) for the connection of equipment.” and CEC Rule 12-1004 (b):“12 (3/8) trade size liquidtight flexible conduit may be used as permitted by this code.” Securements with straps: CEC Rule 12-1010 (3): “When flexible metal conduit is installed, it shall be secured at intervals not exceeding 1.5 m (5 ft) and within 300 mm (12 in.) on each side of every - Reel Content (m) 300 300 - Inside Dia. Min. Max. in. (mm) in. (mm) 0.485(12.32) 0.620(5.08) 0.815(20.70) 1.030(26.16) 1.370(34.80) 1.585(40.26) 2.075(52.71) 0.505(12.83) 0.640(16.26) 0.835(21.21) 1.055(26.80) 1.395(35.43) 1.620(41.15) 2.100(53.34) outlet box or fitting except where flexible metal conduit is fished and except for lengths of not over 900 mm (3 ft) at terminals where flexibility is necessary.” Conductor fill: CEC Rule 12-1014 defines the maximum number of conductor, the CEC Tables 6 provides the maximum number of conductors of one size in trade sizes of conduit, CEC Table 8 provides the maximum allowable per cent conduit fill, and CEC Table 9 provides the cross-sectional areas of conduit. Specific Use and applications: Elevators, Hoistways, in accordance with CEC Rules 38-021 (1) (a) (1) and 38-0221 (1) (a) (iv) Elevators, Cars, in accordance with CEC Rules 38-021 (1) (b) (v) Elevators, Within Machine Rooms, Control Rooms and Machinery Spaces and Control Spaces, in accordance with CEC Rule 38-021 (1) (c) (1) Elevators, Conterweights, in accordance with CEC Rule 38-021 (1) (d) EScalators, in accordance with CEC Rule 38-021 (2) Lifts for persons with physical disabilities, in accordance with CEC Rule 38-021 (3) Theater installation, in accordance with CEC Rule 44-102 (1) Outside Dia. Min. Max. in. (mm) in. (mm) 0.755(19.18) 0.910(23.11) 1.150(29.21) 1.415(35.94) 1.800(45.72) 2.045(51.94) 2.555(64.90) 2.5 3.0 4.0 6.0 7.0 8.0 9.0 (63.5) (76.2) (101.6) (152.4) (177.8) (203.2) (228.6) 7 10 14 19 28 36 54 Working temperatures -20°C to 60°C Listing / Certification Listed. Conforms to UL Standard ANSI/UL 1660 type A Certified. Conforms to CSA 22.2 No. 227.2 type A Standard Colour Safety Orange. Also available in Black and Grey. Part numbers listed designate Orange jacket. Fittings Fittings for Layered Conduit are for that conduit only and are so identified by the marking “FNMC-A”. Recommendation: “Suitable for use with 3700 Series, Type A, Metal Fittings from Thomas & Betts”. Refer to pgs. 101, 102. LNM-P TYPE A 146 0.775(19.69) 0.930(23.62) 1.170(29.72) 1.440(36.58) 1.825(46.36) 2.080(52.83) 2.590(65.79) Inside Bend Radius Wt. in. (mm) kg/30m T&B Conduit Fittings Liquatite® Flexible Conduit — Nonmetallic Type NMC Type Recommended industrial applications: • Machine tools. • Motor hookups. • Food processing equipment. • Extensions from wireways. • Sensor and microswitch wiring found in control consoles. Type NMC A general purpose nonmetallic liquidtight conduit offers excellent protection to wiring from abrasion, sunlight, mild acids, alkaline and oils. Often used for air conditioning hook-ups and other outdoor applications. Trade Size NMC038TB 3/8” NMC050TB 1/2” NMC075TB 3/4” NMC100TB 1” NMC125TB 1-1/4“ NMC150TB 1-1/2” NMC200TB 2” NMC050-1000TB 1/2” NMC075-500TB 3/4” Inside Bend Weight Radius (lb/100ft) 2.00” 3.25” 4.25” 6.50” 8.00” 9.00” 11.00” 3.25” 4.25” 10 11 15 25 34 42 60 11 15 Coil footage Length 100 100 100 100 100 50 50 1000 500 I.D. (in.) Min. Max. .484 .622 .820 1.041 1.380 1.575 2.020 .622 .820 .504 .642 .840 1.066 1.410 1.600 2.045 .642 .840 O.D. (in.) Min. Max. .690 .820 1.030 1.290 1.630 1.865 2.340 .820 1.030 .710 .840 1.050 1.315 1.660 1.900 2.375 .840 1.050 See technical data next page. Use with Bullet® Liquidtight Fittings. *Available in other colours. Consult Customer Service for details. Type NM Specifications Type NMC is intended for installation in accordance with CEC Rule 12-1300 to 12-1306 for Liquidtight Flexible Conduit. -For containment of 600 volt and lower potential circuits. Construction Type B NMC is of the helically wound integral Type B construction. It contains a spiral of rigid PVC reinforcement imbedded within the flexible PVC wall. Working Temperature -20°C to 80°C/Dry 60°C/Wet 70°C/Oil Listed. Conforms to Underwriters Laboratories Standard ANSI/UL 1660 type B Certified. Conforms to CSA 22.2 No. 227.2 type B. The 3/8 through 1-1/4 in. trade sizes are listed and marked for direct burial and in poured concrete. Standard Colour Black Type NMT Type Recommended industrial applications: • Protection of fiber optic cable. • Installation of instrumentation and control cable. • Indoor/outdoor lighting. • Packaging equipment. • Marine and shipboard wiring. • Flexing—component wiring protection on robots, graphic arts equipment, etc. Type NMT Type NMT is an Extra Flexible Liquidtight Nonmetallic Tubing. This lightweight tubing cuts easily and installs quickly. It is ideal for wiring protection in tight quarters and for tight bends. The thin flexible PVC skin allows greater movement for many OEM applications. Used for wiring harnesses, laboratory, equipment, fiber optics, etc. NMT038TB NMT050TB NMT075TB NMT100TB NMT125TB NMT150TB NMT200TB Trade Size 3/8” 1/2” 3/4” 1” 1-1/4 “ 1-1/2” 2” Inside Bend Weight Radius (lb/100ft) .7” .9” 1.1” 1.3” 1.7” 1.9” 2.4” 6 8 10 15 20 26 36 Coil footage Length 100 100 100 100 100 50 50 I.D. (in.) Min. Max. .484 .622 .820 1.041 1.380 1.575 2.020 .504 .642 .840 1.066 1.410 1.600 2.045 *Available in other colours. Consult Customer Service for details. Construction Co-extruded from both flexible and rigid PVC. The rigid spiral PVC reinforcement is imbedded within the wall of the tubing. Working Temperature -20°C to 70°C UL Recognized. 147 Standard Colour Black. O.D. (in.) Min. Max. .690 .820 1.030 1.290 1.630 1.865 2.340 .710 .840 1.050 1.315 1.660 1.900 2.375 T&B Conduit Fittings Liquatite® Flexible Conduit — Nylon The Corrlok® System ® The Corrlok System is comprised of five types of nylon, flexible corrugated conduits designed for a wide range of applications and are intended for use ® with the new Kopex series of fittings and adapters. They are produced by an extrusion/corrugation process resulting in a flexible, seamless corrugated tube. The internal corrugations are well rounded to facilitate easier wire pulling. ® The Corrlok System provides a very light weight, liquidtight flexible raceway alternative that’s easy to work with and stands up to tough environments. Features / Benefits • • • • UL recognized Halogen free Flame resistant High impact and crush strength • • • Because the specially formulated nylons used are nontoxic and self-extinguishing, ® Corrlok is a proven choice in confined areas where hazards from fire are a concern. Applications Resistant to many chemicals Sunlight resistant Extreme temperature range • • • • Passenger rail vehicle wiring Industrial control equipment Machine tools Textile machinery • • • Molding/extrusion equipment Fiber optics Medical equipment Type CL — Standard Weight Type CL Provides the best mechanical strength and protection of the Corrlok conduits. Material Halogen Free Nylon 6 Cat. No. Conduit size (in.) MM MW CL140-30 1/4 CL516-30 5/16 CL10-30 3/8 CL11-30 1/2 CL12-30 3/4 CL13-15 1 CL14-15 1-1/4 CL15-15 1-1/2 10 12 16 20 25 32 40 50 7 10 12 17 23 29 36 48 Nominal Dimensions Inside Outside in. (mm) in. (mm) 0.226 0.374 0.452 0.633 0.846 1.063 1.380 1.810 (6.5) (9.5) (11.5) (16.1) (22.5) (27.0) (35.0) (46.0) 0.394 0.512 0.622 0.826 1.122 1.358 1.673 2.145 (10.0) (13.0) (15.8) (21.0) (28.5) (34.5) (42.5) (54.5) Min. Inside Bend Radius Static in. (mm) 0.8 1.0 1.5 1.7 2.0 2.5 2.8 3.3 (20.3) (25.4) (38.1) (43.2) (50.8) (63.5) (71.1) (83.8) Standard Wt. Length kg/30m (m) 2.0 2.5 5.0 7.0 9.5 13.0 16.0 19.0 30 30 30 30 30 15 15 15 Working Temperatures -40°C to 105°C Fitting Pullout 150 lb ®(1/2” and larger). To be® used with Kopex fittings of the Corrlok System. Listing / Certification UL Recognized Component, 600 V, 105°C, Vertical Flame, Liquidtight, UV and Impact Tested. Standard Colour Black. Other colours available upon request. Type CLL — Light Weight Type - CLL This light weight version provides many of the same qualities of Type CL but with Type CLL improved flexibility. Material Halogen Free Nylon 6 Cat. No. CLL10-30 CLL11-30 CLL12-30 CLL13-15 CLL14-15 CLL15-15 CLL17-10 CLL350-10 Conduit size (in.) MM MW 3/8 1/2 3/4 1 1-1/4 1-1/2 2-1/2 3-1/2 16 20 25 32 40 50 70 95 12 17 23 29 36 48 70 95 Nominal Dimensions Inside Outside in. (mm) in. (mm) 0.452 0.633 0.865 1.087 1.420 1.850 2.645 3.600 (11.5) (16.1) (22.0) (27.6) (36.0) (47.0) (67.0) (91.5) 0.622 0.826 1.122 1.358 1.673 2.145 3.150 4.170 (15.8) (21.0) (28.5) (34.5) (42.5) (54.5) (80.0) (106.0) Min. Inside Bend Radius Static in. (mm) Wt. kg/30m Standard Length (m) 0.7 (17.8) 0.8 (20.3) 1.2 (30.4) 1.4 (35.6) 2.4 (61.0) 2.8 (71.1) 6.3 (160.0) 8.3 (210.8) 3.4 4.4 6.7 9.1 11.0 16.0 32.0 52.0 30 30 30 15 15 15 10 10 Working temperatures -40°C to 105°C intermitting to 150°C Fitting Pullout 40 lb (1/2” and larger). To be®used with ® Kopex fittings of the Corrlok System. Listing / Certification UL Recognized Component, 600 V, 105°C, Vertical Flame, Liquidtight, UV and Impact Tested. Standard Colour Black. Other colours available upon request. 148 T&B Conduit Fittings Liquatite® Flexible Conduit — Nylon Corrlok® System — Type CLFR, Low Fire Hazard Cat. No. CLFR516-30 CLFR10-30 CLFR11-30 CLFR12-30 CLFR13-15 CLFR14-15 CLFR15-15 Conduit size (in.) MM MW 5/16 3/8 1/2 3/4 1 1-1/4 1-1/2 12 16 20 25 32 40 50 10 12 17 23 29 36 48 Nominal Dimensions Inside Outside in. (mm) in. (mm) 0.370 0.460 0.653 0.854 1.090 1.381 1.835 (9.4) (11.7) (16.6) (21.7) (27.7) (35.1) (46.6) 0.512 0.622 0.826 1.122 1.358 1.673 2.145 (13.0) (15.8) (21.0) (28.5) (34.5) (42.5) (54.5) Min. Inside Bend Radius Static in. (mm) 1.0 1.5 1.7 2.0 2.5 2.8 3.3 (25.4) (38.1) (43.2) (51.0) (63.5) (71.1) (83.8) Wt. kg/30m Standard Length (m) 2.5 5.0 7.0 9.5 13.0 16.0 19.0 30 30 30 30 15 15 15 Type CLFR Combustion & Flammability Properties Test Value UL94 UL360 ASTM E162 ASTM E662 (NFPA-258) Smoke Generation (Non-Flaming) ASTM E662 (NFPA-258) Toxic Gas Generation BOMBARDIER SMP 800-C Vertical Burn (Material) Vertical Burn (Conduit) Flame Spread Index Smoke Generation (Flaming) V-O Rating Pass 1.0 Ds 35@1.5 Min. Ds 85@4.0 Min. Ds 5@1.5 Min. Ds 24@4.0 Min. Pass No Flaming Drips No Flaming Drips No Flaming Drips Type CLFR ® A new addition to the Corrlok System family of conduits, Type CFLR conduit is made from a specially modified Nylon Material with excellent self-extinguishing characteristics and minimal smoke and toxic gas gene-ration. CLFR is an excellent choice for confined inhabited areas such as Public Transit/Rail Vehicles, Subway Stations, Tunnels, Etc. Material: Halogen Free Nylon 6 UL94 VO Fitting Pullout 150 lb (1/2” and larger). To be used with ® ® Kopex fittings of the Corrlok System. Listing/Certification UL Recognized Component, 600 V, 105°C, Vertical Flame, Liquidtight, UV and Impact Tested. Standard Colour: Black. Other colours available upon request. Test data is based on controlled laboratory conditions and does not necessarily reflect performance in actual fire conditions. Additional product information available upon request. Corrlok® System — Type CLR, Robotics Type CLR Very light weight and extremely flexible. Ideally suited for robotic equipment. This tubing is intended for applications requiring continuous, repeated flexible motion. Cat. No. Conduit size (in.) MM MW CLR10-30 3/8 CLR11-30 1/2 CLR12-30 3/4 CLR13-15 1 CLR14-15 1-1/4 CLR15-15 1-1/2 CLR17-10 2-1/2 CLR350-10 3-1/2 16 20 25 32 40 50 70 95 12 17 23 29 36 48 70 95 Nominal Dimensions Inside Outside in. (mm) in. (mm) 0.452 0.633 0.865 1.087 1.420 1.850 2.645 3.600 (11.5) (16.1) (22.0) (27.6) (36.0) (47.0) (67.0) (91.5) 0.622 0.826 1.122 1.358 1.673 2.145 3.150 4.170 (15.8) (21.0) (28.5) (34.5) (42.5) (54.5) (80.0) (106.0) Min. Inside Bend Radius Static in. (mm) Wt. kg/30m Standard Length (m) 0.7 (17.8) 0.8 (20.3) 1.2 (30.5) 1.4 (35.6) 2.4 (61.0) 2.8 (71.1) 6.3 (160.0) 8.3 (210.8) 3.4 4.4 6.7 9.1 11.0 16.0 32.0 52.0 30 30 30 15 15 15 10 10 Material: Halogen Free Nylon 12 Working temperatures -50°C to 95°C intermitting to 150°C FIitting® Pullout: 65 lb.To be ®used with Kopex fittings of the Corrlok System. Listing/ Certification UL Recognized Component, 600 V, 105°C, Vertical Flame, Liquidtight, UV and Impact Tested. Standard Colour: Black. Other colours available upon request. Corrlok® System — Type CCG, Commercial Grade Type CCG This commercial grade product is exceptionnally light weight and provides a cost effective alternative. Cat. No. Conduit size (in.) MM MW CCG10-30 3/8 CCG11-30 1/2 CCG12-30 3/4 CCG13-15 1 CCG14-15* 1-1/4 CCG15-15 1-1/2 * Not available 16 20 25 32 40 50 12 17 23 29 36 48 Nominal Dimensions Inside Outside in. (mm) in. (mm) 0.452 0.633 0.870 1.100 1.420 1.850 (11.5) (16.1) (22.0) (27.9) (36.0) (47.0) 0.622 0.826 1.122 1.358 1.673 2.145 (15.8) (21.0) (28.5) (34.5) (42.5) (54.5) Min. Inside Bend Radius Static in. (mm) 1.0 1.5 1.8 2.0 2.4 2.8 (25.4) (38.1) (45.7) (51.0) (61.0) (71.1) 149 Wt. kg/30m Standard Length (m) 3.0 4.0 6.0 8.2 10.5 15.3 30 30 30 15 15 15 Material: Halogen Free Nylon 16 Working temperatures: -20°C to 90°C Standard Colour: Black. Other colours available upon request. To be used with ® Kopex fittings of the ® Corrlok System. T&B Conduit Fittings Liquatite® Flexible Conduit — Nylon ® ® The Corrlok System now features KOPEX Fittings The new, improved slim fitting is great for use in tight areas and is molded in high impact Nylon. The two piece design is easier than ever to assemble • Fast Installation • Recognized • Liquidtight — Equivalent to IP 65 and NEMA 4 • 360° Retention — High pullout strength • Fitting Pullout — Minimum 150 lb and to re-use. After sliding the backshell onto the conduit, simply seat the conduit into the fitting body and click together. No tools required! Straight NPT Threaded Fittings Cat. No. (in.) Fitting size MM CF-140 CF-516 CF-10 CF-11 CF-12 CF-13 CF-14 CF-15 1/4 5/16 3/8 1/2 3/4 1 1-1/4 1-1/2 10 12 16 20 25 32 40 50 MW Thread Size 7 10 12 17 23 29 36 48 PG-7 PG-9 1/2 NPT 1/2 NPT 3/4 NPT 1NPT 1-1/4 NPT 1-1/2 NPT PG Thread Thread Cat. No. Size CFP-10 CFP-11 CFP-12 CFP-13 CFP-14 CFP-15 Cat. No. PG-11 PG-13.5 PG-21 PG-29 PG-36 PG-48 A CF-140 CF-516 CF-10 CF-11 CF-12 CF-13 CF-14 CF-15 Metric Thread Thread Cat. No. Size CFM-516 CFM-10 CFM-11 CFM-12 CFM-13 CFM-14 CFM-15 12 mm 16 mm 20 mm 25 mm 32 mm 40 mm 50 mm Approx. Dimensions B C 31/32 1-3/32 1-1/16 1-5/16 1-5/8 2 2-5/16 2-13/16 1-13/32 1-3/8 1-1/2 1-1/2 1-17/32 1-21/32 1-13/16 1-13/16 15/32 15/32 1/2 1/2 9/16 21/32 23/32 23/32 90° Angle NPT Threaded Fittings Cat. No. Fitting size (in.) MM MW CF-140A 1/4 CF-516A 5/16 CF-20 3/8 CF-21 1/2 CF-22TB 3/4 CF-23 1 CF-24 1-1/4 CF-25 1-1/2 10 12 16 20 25 32 40 50 7 10 12 17 23 29 36 48 Thread Size PG-7 PG-9 1/2 NPT 1/2 NPT 3/4 NPT 1NPT 1-1/4 NPT 1-1/2 NPT Unit Standard Pack Carton 1 1 25 25 10 10 5 2 100 50 30 20 10 10 PG Thread Thread Cat. No. Size Cat. No. CFM-516A CFP-20 PG-11 CFM-20 CFP-21 PG-13.5 CFM-21 CFP-22 PG-21 CFM-22 CFP-23 PG-29 CFM-23 CFP-24 PG-36 CFM-24 CFP-25 PG-48 CFM-25 Cat. No. CF-140A CF-516A CF-20 CF-21 CF-22 CF-23 CF-24 CF-25 150 Metric Thread Thread Size 12 mm 16 mm 20 mm 25 mm 32 mm 40 mm 50 mm A Approx. Dimensions B C 1-3/8 1-15/32 1-5/8 1-3/4 2-3/16 2-1/2 2-3/4 3-3/8 19/32 1-11/16 1-27/32 2 2-5/16 2-9/16 3 3-1/2 15/32 15/32 1/2 1/2 9/16 21/32 23/32 23/32 T&B Conduit Fittings Liquatite® Flexible Conduit — Nylon Corrlok® System — Flange, Jumbo Straight Screw Fitting size (in.) MM MW Cat. No. CFF-17 CF-350 2-1/2 3-1/2 70 95 70 95 Unit Pack A 1 1 2.362 2.913 Nominal Dimensions B C D Required E 3.149 3-7/8 2-1/16 4-3/16 4.251 4-31/32 2-1/16 5-7/32 F 17/64 17/64 Corrlok® System — Flange, Jumbo 90° Angle Screw Cat. No. Fitting size (in.) MM MW CFF-27 2-1/2 CFF-350A 3-1/2 70 95 70 95 Unit Pack A 1 1 2.362 2.913 Nominal Dimensions B C D Required E F 3.149 3-25/32 5-1/32 4-11/32 17/64 4.251 4-31/32 6-17/32 5-11/16 17/64 Both the Flanged Straight and Flanged 90° Angle fittings on this page do not have threaded ends but are intended to be mounted as a bulkhead device. Part numbers include clamps. Seals are provided for liquidtight connections. Corrlok® System — Type CTC, T Fitting Cat. No. CTC-140 CTC-516 CTC-10 CTC-11 CTC-12 CTC-13 (in.) Fitting size MM 1/4 X 3 5/16 X 3 3/8 X 3 1/2 X 3 3/4 X 3 1X 3 10 12 16 20 25 32 MW A 7 10 12 17 23 29 2-11/16 2-11/16 2-3/4 3-5/32 3-3/4 4-5/16 Nominal Dimensions B C 1-31/32 1-31/32 2 2-9/32 2-13/16 3-5/16 1-17/32 1-17/32 1-1/2 1-11/16 2-1/32 2-13/32 D Weight Oz. 1-1/16 1-1/16 1-7/32 1-3/8 1-11/16 2 0.8 0.8 0.9 1.3 2.3 2.3 Corrlok® System — Type TR, T Reducer Cat. no. TR-516-140 TR-10-516 TR-11-516 TR-11-10 TR-12-516 TR-12-10 TR-12-11 TR-13-11 Trade Size (in.) reduce to U.S. Trade MM (NW) reduce to MM (NW) 5/16 3/8 1/2 1/2 3/4 3/4 3/4 1 · · · · · · · · 1/4 5/16 5/16 3/8 5/16 3/8 1/2 1/2 12 (10) 16 (12) 20 (17) 20 (17) 25 (23) 25 (23) 25 (23) 32 (29) · · · · · · · · 10 (7) 12 (10) 12 (10) 16 (12) 12 (10) 16 (12) 20 (17) 20 (17) 151 T&B Conduit Fittings Liquatite® Flexible Conduit — Nylon The Corrlok® System — Accessories The Corrlok components provide Designers and Electricians with many options for configuring and installing this raceway system. These accessories allow a simplified, quick method of assembly and are perfectly suited for pre-wiring of harnesses. Type MB — Mounting Bracket Cat. No. Corrlok Conduit Size (in.) MM MW MB-140 1/4 MB-516 5/16 MB-10TB 3/8 MB-11 1/2 MB-12 3/4 MB-13 1 MB-14 1-1/4 MB-15 1-1/2 10 12 16 20 25 32 40 50 A 7 10 12 17 23 29 36 48 B Nominal Dimensions C D 7/8 1/2 15/16 7/8 1/2 15/16 1-1/16 19/32 1-1/16 1-11/32 3/4 1-3/8 1-23/32 15/16 1-23/32 2-3/32 1-1/16 2-1/32 2-17/32 1-9/32 2-15/32 3-3/16 1-1/2 3-1/32 15/32 15/32 17/32 11/16 13/16 15/16 1-1/16 1-9/32 E F Weight Oz. 5/16 5/16 11/32 13/32 13/32 13/32 13/32 13/32 5/32 5/32 3/16 1/4 1/4 1/4 1/4 1/4 0.1 0.1 0.1 0.2 0.3 0.4 0.7 1.2 Type FTA — Female Threaded Adapter Corrlok Conduit Size Cat. No. in. MM MW 1/2-28 FTA-U12516 FTA-U15516 FTA-U18516 5/16 12 10 FTA-U1810 FTA-U2310 3/8 16 12 1/2 20 17 3/4 25 FTA-U2311 FTA-U2411 FTA-U2911 FTA-U3411 FTA-U2312 FTA-U2912 FTA-U3412 FTA-U3512 Internal Thread UNEF 5/8-24 3/4-20 3/4-20 15/16-20 15/16-20 1-20 13/16-18 1-3/8-18 15/16-20 23 1-3/16-18 1-3/8-18 1-7/16-18 Type FTA adapters have internal, female UNEF threads which are sized to match those of commonly used circular pin fittings. This component provides a secure means to attach these quick disconnect multi-pin fittings to the Corrlok System. This assembly eliminates the need for back shells and heat shrinkable boots while providing excellent protection to circuit conductors. Other thread sizes and types available. Consult your Regional Sales Office for further details. Type PSA — Pro Sensor Adapters Corrlok Conduit Size Cat. No. PSA-M8140 PSA-M12140 PSA-M18140 PSA-M130140 in. MM MW Internal Thread UNEF M8 X 1 1/4 10 7 M12 X 1 M18 X 1 M30 X 1.5 PSA-M12516 PSA-M18516 3/4 16 152 12 M12 X 1 M18 X 1 Type PSA adapters have internal ISO Metric threads which match those found on most barrel type proximity sensors. Like the FTA series, this adapter provides a means to mate proximity sensors to the Corrlok System protect the sensor’s cable. The adapter is molded in transparent nylon which permits monitoring of the LED indicator built into many sensor designs. T&B Conduit Fittings ® Liquatite Flexible Conduit — Engineering Information Conduit Cutting Benfield Vise The Benfield cutting vise is recommended for accurate, straight cuts in the field. This light weight cast iron vise can either be bench mounted or carried in the tool box. The clamping mechanism securely holds the flexible conduit while the slots guide a hack saw to ensure a clean square cut. Suitable for conduit trade sizes of 3/8” to 1-1/2”. Works well on other tubings and materials too. Order #BLC-1 Weight 2.4 lb Cutting Flexible Conduits Proper cutting methods for flexible conduits are important to ensure a sealed connection when assembled with intended fittings. Furthermore, in the case of flexible conduits containing steel, a clean, square cut is necessary for establishing a good connection for continuity of the ground path. Hand Cutting in the Field When using a hand held hack saw, care should be taken to make a square clean cut. This can be easily achieved through the use of the cutting vise shown on this page. For best results, a blade having 24 to 32 teeth per inch with no-set is recommended. Conduit Wire Fill Charts Repetitive Production Cutting It has been our experience that in order to achieve the best results, a band saw having a blade with 24 to 32 teeth per inch at a speed of 300 to 350 feet per minute should be used. A no-set blade will produce the cleanest cut. Conduit should be held and supported in a safe manner. Abrasive cut-off wheels and chop saws are not recommended. Per Canadian Electrical Code Flexible Metal Conduit Trade Internal Size Diameter (in.) (in.) (mm) 5/16 3/8 7/16 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 0.312 (7.92) 0.375 (9.53) 0.437 (11.10) 0.625 (15.88) 0.812 (20.62) 1.000 (25.40) 1.250 (31.75) 1.500 (38.10) 2.000 (50.80) 2.500 (63.50) 3.000 (76.20) 3.500 (88.9) 4.000 (101.60) Liquidtight Flexible Metal Conduit Trade Internal Size Diameter (in.) (in.) (mm) 3/8 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 0.484 (12.29) 0.622 (15.80) 0.820 (20.83) 1.041 (26.44) 1.380 (35.05) 1.575 (40.01) 2.020 (51.31) 2.480 (62.99) 3.070 (77.98) 3.500 (88.90) 4.000 (101.60) Total Area 100 % (in. ) (mm2) 2 0.076 0.110 0.150 0.307 0.518 0.785 1.227 1.767 3.142 4.909 7.069 9.621 12.566 (1.9) (2.8) (3.8) (7.8) (13.2) (19.9) (31.2) (44.9) (79.8) (124.7) (179.5) (244.4) (319.2) Total Area 100 % (in. ) (mm2) 2 0.184 0.304 0.528 0.851 1.496 1.948 3.205 4.831 7.402 9.621 12.566 (4.7) (7.7) (13.4) (21.6) (38.0) (49.5) (81.4) (122.7) (188.0) (244.4) (319.2) 2 Wires 31 % (in.2) (mm2) 0.024 0.034 0.046 0.095 0.161 0.243 0.380 0.548 0.974 1.522 2.191 2.983 3.896 (0.6) (0.9) (1.2) (2.4) (4.1) (6.2) (9.7) (13.9) (24.7) (38.7) (55.7) (75.8) (98.9) 2 Wires 31 % (in.2) (mm2) 0.057 0.094 0.164 0.264 0.464 0.604 0.993 1.497 2.295 2.983 3.896 153 (1.4) (2.4) (4.2) (6.7) (11.8) (15.3) (25.2) (38.0) (58.3) (75.8) (98.9) Over 2 Wires 40 % 2 (in. ) (mm2) 0.031 0.044 0.060 0.123 0.207 0.314 0.491 0.707 1.257 1.964 2.827 3.848 5.027 (0.8) (1.1) (1.5) (3.1) (5.3) (8.0) (12.5) (18.0) (31.9) (49.9) (71.8) (97.8) (127.7) Over 2 Wires 40 % 2 (in. ) (mm2) 0.074 0.122 0.211 0.340 0.598 0.779 1.282 1.932 2.961 3.848 5.027 (1.9) (3.1) (5.4) (8.6) (15.2) (19.8) (32.6) (49.1) (75.2) (97.8) (127.7) 1 Wire 53 % (in.2) (mm2) 0.041 0.059 0.079 0.163 0.274 0.416 0.650 0.937 1.665 2.602 3.746 5.099 6.660 (1.0) (1.5) (2.0) (4.1) (7.0) (10.6) (16.5) (23.8) (42.3) (66.1) (95.2) (129.5) (169.2) 1 Wire 53 % (in.2) (mm2) 0.098 0.161 0.280 0.451 0.793 1.033 1.699 2.560 3.923 5.099 6.660 (2.5) (4.1) (7.1) (11.5) (20.1) (26.2) (43.1) (65.0) (99.6) (129.5) (169.2) T&B Conduit Fittings Liquatite® Flexible Conduit — Engineering Information Conduit Wire Fill Charts (continued) Per Canadian Electrical Code Liquidtight Non-Metallic Conduit — Type A Total Trade Size (in.) 3/8 1/2 3/4 1 1-1/4 1-1/2 2 Internal Diameter (in.) (mm) 0.485 0.620 0.855 1.030 1.370 1.585 2.045 Total Area 100 % (in.2) (mm2) (12.32) (15.75) (20.70) (26.16) (34.80) (40.26) (51.94) 0.185 0.302 0.522 0.833 1.474 1.973 3.285 Liquidtight Non-Metallic Conduit — Type B Total Trade Internal Size Diameter (in.) (in.) (mm) 3/8 1/2 3/4 1 1-1/4 1-1/2 2 0.485 0.620 0.855 1.030 1.370 1.585 2.045 (12.32) (15.75) (20.70) (26.16) (34.80) (40.26) (51.94) (4.7) (7.7) (13.3) (21.2) (37.4) (50.1) (83.4) Total Area 100 % (in. ) (mm2) 2 0.185 0.302 0.522 0.833 1.474 1.973 3.285 (4.7) (7.7) (13.3) (21.2) (37.4) (50.1) (83.4) Knockout Hole Sizes NPT Threaded Fittings Fitting (in.) 3/8 1/2 3/4 1 1-1/4 1-1/2 2 0.057 0.094 0.162 0.258 0.457 0.612 1.018 (1.5) (2.4) (4.1) (6.6) (11.6) (15.5) (25.9) 2 Wires 31 % (in.2) (mm2) 0.057 0.094 0.162 0.258 0.457 0.612 1.018 (1.5) (2.4) (4.1) (6.6) (11.6) (15.5) (25.9) Over 2 Wires 40 % (in.2) (mm2) 0.074 0.121 0.209 0.333 0.590 0.789 1.314 1 Wire 53 % (in.2) (mm2) (1.9) (3.1) (5.3) (8.5) (15.0) (20.0) (33.4) 0.098 0.160 0.276 0.442 0.781 1.046 1.741 Over 2 Wires 40 % 2 (in. ) (mm2) 0.074 0.121 0.209 0.333 0.590 0.789 1.314 (2.5) (4.1) (7.0) (11.2) (19.8) (26.6) (44.2) 1 Wire 53 % (in.2) (mm2) (1.9) (3.1) (5.3) (8.5) (15.0) (20.0) (33.4) 0.098 0.160 0.276 0.442 0.781 1.046 1.741 (2.5) (4.1) (7.0) (11.2) (19.8) (26.6) (44.2) Common Conversion Length Knockout Thread (in.) 1/2 NPT 1/2 NPT 3/4 NPT 1 NPT 1-1/4 NPT 1-1/2 NPT 2 NPT 2 Wires 31 % (in.2) (mm2) (12.7) (12.7) (19.1) (25.4) (31.8) (38.1) (50.1) Diameter in. (mm) 7/8 (22.2) 7/8 (22.2) 13/32 (27.8) 123/64 (34.5) 1-23/32(34.5) 2 (50.8) 2-1/2 (63.5) English Measure Metric Measure 1 Foot 1 Meter 1 Inch 1 Millimeter 1 Inch 1 Centimeter 0.305 Meters 3.281 Feet 25.4 Millimeters 0.039 Inches 2.54 Centimeters 0.394 Inches Weight English Measure Metric Measure 1 Pound 1 Pound 1 Kilogram 1 Gram 1 Ounce 454 Grams 0.454 Kilograms 2.205 Pounds 0.035 Ounces 28.349 Grams Temperature C° = Degrees Centigrade F° = Degrees Farenheit C° = (F° - 32) 5 F° = (C° x 9) + 32 9 5 154 T&B Conduit Fittings Liquatite® Flexible Conduit Standard Dimensions and Packaging — Types Reel Sizes LT - LOR - EF - LA - CSA - ALT - AT ATLA - ATX - CEA - ZHLA - LAS EMS - EMSP - NMC - NMT - ACEA Trade Size (in.) Type Min. Inner dia. Max. Min. Outer Dia. Max. 1/4 5/16 3/8 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 1-1/2 4 5 6 10 11 12 13 14 15 16 17 18 350 19 500 600 0.245 0.385 0.484 0.622 1.820 1.041 1.380 1.575 2.020 2.480 3.070 3.500 4.000 4.975 6.015 0.265 0.405 0.504 0.642 0.840 1.066 1.410 1.600 2.045 2.505 3.100 3.540 4.040 5.035 6.075 0.450 0.570 0.690 0.820 1.030 1.290 1.630 1.865 2.340 2.840 3.460 3.960 4.460 5.505 6.565 0.470 0.590 0.710 0.840 1.050 1.315 1.660 1.900 2.375 2.875 3.500 4.000 4.500 5.565 6.625 Trade Size (in.) 58” LT-LA-EF 42” LT-LA-EF LT 31” LA EF LT 31” Special LA EF 24” LT-LA-EF 3/8 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 5 6 6,000 4,500 2,500 1,500 1,000 750 500 275 175 175 100 - 1,000 - 1,000 1,000 500 400 200 - 1,000 1,000 500 400 - 1,000 1,000 500 400 200 - 150 100 - 200 150 100 - 150 100 - 500 500 - Approx. Reel Dimensions in. (mm) “A” “B” “C” 24 (610) 31 (760) 31 (760) Special 42 (1029) 58 (1421) 19-1/2 (495) 19-1/2 (495) 19-1/2 (495) 20 (508) 29-1/2 (749) 12 (305) 12 (305) 15 (381) 24 (610) 28 (711) Cartons Cat. No. Trade Size (in.) Standard Carton All types Standard Carton Type LNM-P 038 050 075 100 125 150 200 250 300 350 3/8 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 30 30 30 30 15 15 15 8 8 8 75 60 50 30 30 15 15 - 400 500 600 4 5 6 8 8 8 - 155 All standard lengths packaged in specially-designed, functional cartons to eliminate knots and tangles. These compact cartons save storage and warehouse space, making handling easier. Each carton label is clearly marked and colour coded with conduit size, type, colour, and footage as well as the NEMA and NAED bar code standards. Special Cut Lengths Available Thomas & Betts can supply “cut-tolength” orders. Consult your Regional Sales Office for details. T&B Conduit Fittings Conduit Dimensional Data Rigid Metal Conduit (Extract from CSA C22.2 No. 45.1) Metric Trade Designator (As per CEC 2009) Imperial Trade Size Threads per in. Nominal Internal Dia. (mm) Nominal Internal Dia. (in.) External Diameter (mm) External Diameter (in.) Wall Thickness (mm) Wall Thickness (in.) 12 16 21 27 35 41 53 63 78 91 103 129 155 3/8 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 5 6 18 14 14 11-1/2 11-1/2 11-1/2 11-1/2 8 8 8 8 8 8 12.52 16.05 21.23 27.60 35.41 41.25 52.91 63.22 78.49 90.69 102.87 128.85 154.76 0.493 0.632 0.836 1.063 1.394 1.624 2.083 2.489 3.090 3.570 4.050 5.073 6.093 17.1 21.3 26.7 33.4 42.2 48.3 60.3 73.0 88.9 101.6 114.3 141.3 168.3 0.675 0.840 1.050 1.315 1.660 1.900 2.375 2.875 3.500 4.000 4.500 5.563 6.625 2.31 2.64 2.72 3.20 3.38 3.51 3.71 4.90 5.21 5.46 5.72 6.22 6.76 0.091 0.104 0.107 0.126 0.133 0.138 0.146 0.193 0.205 0.215 0.225 0.245 0.266 Knockout (sliphole) Sizes for Electrical Conduits and Fittings Metric Trade Designator Diameter (As per CEC 2009) Knockout Diameter Imperial Trade Size (mm) (in.) (mm) (in.) (mm) (in.) 16 21 27 35 1/2 3/4 1 1-1/4 21.84 27.79 34.52 43.66 0.860 1.094 1.359 1.719 22.33 28.17 34.93 44.04 0.875 1.109 1.375 1.734 23.01 28.96 35.71 44.83 0.906 1.140 1.406 1.765 Minimum Nominal Maximum Electrical Metallic Tubing (Extract from CSA C22.2 No. 83.1) Metric Trade Designator (As per CEC 2009) Imperial Trade Size Nominal Internal Dia. (mm) Nominal Internal Dia. (in.) Outside Diameter (mm) Outside Diameter (in.) Wall Thickness (mm) Wall Thickness (in.) 16 21 27 35 41 53 63 78 91 103 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 15.80 20.93 26.64 35.05 40.89 52.50 69.37 85.24 97.38 110.08 0.622 0.824 1.049 1.380 1.610 2.067 2.731 3.355 3.834 4.334 217.9 23.4 29.5 38.4 44.2 55.8 73.0 88.9 101.6 114.3 0.705 0.921 1.161 1.512 1.740 2.197 2.874 3.500 4.000 4.500 1.07 1.24 1.45 1.65 1.65 1.65 1.83 1.83 2.11 2.11 0.042 0.049 0.057 0.065 0.065 0.065 0.072 0.072 0.083 0.083 156 T&B Conduit Fittings Conduit Dimensional Data Flexible Metal Conduit (Extract from CSA C22.2 No. 56) Imperial Trade Size Minimum Internal Diameter (mm) Minimum Internal Diameter (in.) Maximum External Diameter (mm) Maximum External Diameter (in.) 5/16 3/8 7/16 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 7.92 9.52 11.10 15.88 20.62 25.40 31.75 38.10 50.80 63.50 76.20 88.90 101.60 0.312 0.375 0.437 0.625 0.812 1.000 1.250 1.500 2.000 2.500 3.000 3.500 4.000 12.95 15.49 17.15 23.37 28.07 35.05 41.40 49.53 62.23 77.72 90.42 103.12 115.82 0.510 0.610 0.675 0.920 1.105 1.380 1.630 1.950 2.450 3.060 3.560 4.060 4.560 Liquidtight Flexible Conduit (Extract from CSA C22.2 No. 56) Imperial Trade Size Minimum Internal Dia. (mm) Minimum Internal Dia. (in.) Minimum Overall Diameter (mm) Minimum Overall Diameter (in.) Maximum Overall Diameter (mm) Maximum Overall Diameter (in.) 3/8 1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 12.29 15.80 20.83 26.44 35.05 40.01 51.31 62.99 77.98 88.90 101.60 0.484 0.622 0.820 1.041 1.380 1.575 2.020 2.480 3.070 3.500 4.000 17.5 20.8 25.2 32.8 41.4 47.4 59.4 72.1 87.9 100.6 113.3 0.690 0.820 1.030 1.290 1.630 1.865 2.340 2.840 3.460 3.960 4.460 18.0 21.3 26.7 33.4 42.2 48.3 60.3 73.0 88.9 101.6 114.3 0.710 0.840 1.050 1.315 1.660 1.900 2.375 2.875 3.500 4.000 4.500 Flexible Liquidtight Nonmetallic Conduit (Extract from CSA C22.2 No. 227.2) Imperial Trade Size Minimum Internal Dia. (mm) Minimum Internal Dia. (in.) Maximum Internal Dia. (mm) Maximum Internal Dia. (in.) Minimum Dia. (mm) Minimum Dia. (in.) Maximum Dia. (mm) Maximum Dia. (in.) 3/8 1/2 3/4 1 1-1/4 1-1/2 2 12.32 15.75 20.70 26.16 34.80 40.26 51.94 0.485 0.620 0.815 1.030 1.370 1.585 2.045 13.83 16.26 21.21 27.05 35.43 41.15 52.83 0.505 0.640 0.835 1.065 1.395 1.620 2.080 19.18 23.11 29.21 35.94 45.72 51.94 66.17 0.755 0.910 1.150 1.415 1.800 2.045 2.605 19.69 23.62 29.72 36.58 46.36 52.83 67.06 0.775 0.930 1.170 1.440 1.825 2.080 2.640 157 T&B Conduit Fittings Conduit—Chemical Resistance Guide CHEMICAL A ASTM Fuel A ASTM Fuel B ASTM Fuel C ASTM Oil No. 1 ASTM Oil No. 2 ASTM Oil No. 3 Acetaldehyde Acetamide Acetate Solvents Acetic Acid (Glacial) Acetic Acid Acetic Acid Acetic Anhydride Acetone Acetyl Bromide Acetyl Chloride Acetylene Acrylonitrite Adipic Acid Alcohols Alcohols (Aliphatic) Alkalies Allyl Alcohol Aluminium Salts Aluminum Chloride Aluminum Sulfate (Alums) Aluminum Sulfide Alums Ammonia Ammonia Ammonia (Anhydrous Liquids) Ammonia (Aqueous) Ammoniated Latex Ammonium Acetate Ammonium Carbonate Ammonium Chloride Ammonium Chloride Ammonium Hydroxide Ammonium Nitrate Ammonium Persulfate Ammonium Salts Ammonium Sulfate Ammonium Sulfide Ammonium Thicyanide Amyl Acetate Amyl Alcohol Amyl Chloride Aniline Aniline Hydrochloride Aniline Oils Animal Fats & Oils Aniseed Oil Anthracene Antifreeze Compounds Antimony Salts Aqua Regia Aromatic Fuels Aromatic Hydrocarbons Arsenic Salts Asphalt Attar of Roses A- Good to excellent B- Fair to Good % PVC PU C D B C 40% 50% D C 40% 10% B D D D B D D D C C B NYLONS 6 12 A B B B B A B A A A A D D C D A C C B B A A A A A A A C A B A A A B A B B B B 10% B A A A A A D A A B B 10% A A A A B B B D D A A B B B D C C D D A A A B A B B A A A A D D B D B D D A D A A CHEMICAL B Banana Oil Barium Carbonate Barium Chloride Barium Hydroxide Barium Salts Barium Sulfide Battery Acid Benzaldehyde Benzaldehyde Benzene Benzine (Petroleum Ether) Benzoic Acid Benzole Benzyl Bitumen Borax Bordeaux Mixture Boric Acid Brake Fluid % PVC B A A 30% 0.3 % D C A A A A A C A C A B A B A D D B C B A C A A B A C A A B B A A A C C A A A A B A B B A A A D A C A A A A A B C A B A D D C C D A B C D C D D D B B D C B C C B C B A B B B D B D B B 10% 20% A A A B B B B B A D D A A A 6% 40% A B D B A D D B < 5% < 5% C D C D D 1% 10% B PVC- Polyvinyl chloride PU- Polyurethane 158 B A Brine Bromine Bunker Oil Butane Butanol Butyl Acetate Butyl Alcohol Butylene Glycol Butyric Acid C- Fair to Limited D- Unsatisfactory NYLONS 6 12 D Brake Fluid A C Calcium Carbonate Calcium Chloride Calcium Chloride Calcium Hydroxide Calcium Hypochlorite Calcium Nitrate Calcium Sulfate Camphor Carbolic Acid (Phenol) Carbon Dioxide Carbon Disulfide Carbon Tetrachloride Carbonic Acid Casein Castor Oil Catechol Caustic Soda Cello - Solv Chlorinated Hydrocarbons Chlorinated Lime Chlorine Chlorine (water solution) Chlorine Gas (dry & wet) Chloroacetic Acid Chlorobenzene Chlorobromomethane Chloroform Chrome Baths Chromic Acid Chromic Acid PU D D T&B Conduit Fittings Conduit—Chemical Resistance Guide CHEMICAL C (cont’d) Chromic / Sulfuric Acid Chromium Potassium Sulfate Chromium Salts Citric Acid Coal Tar Coconut Oil Copper Salts Corn Oil Cottonseed Oil Creosote Cresol Cresylic Acid Cupric Chloride Cupric Nitrate Cupric Sulfate Cyclohexane Cyclohexanol Cyclohexanone D DDT Weed Killer DOP DTE Oil Decalin Degreasing Fluids Detergents (dishwashing) Di Iso Cyanate Di Methyl Formamide Di Methyl Hydrazine Di-isodecyl Phthalate Dibutyl Ether Dibutyl Phthalate Dichlorobenzene Diesel Fuel Diesel Oils Diester Oil Diethyl Ether Diethylene Glycol Dimethyl Acetamide Dimethyl Formamide Dioctyl Phthalate Dioxane Dodecyl Mercaptan Dow General Weed Killer (H20) Dow General Weed Killer (Phenol) Dowtherm E Edible Fats and Oils Esters Ether Ethyl Acetate Ethyl Alcohol Ethyl Bromide Ethyl Chloride Ethylene Chloride Ethylene Dichloride Ethylene Glycol F Fatty Acids Ferric Chloride A- Good to excellent B- Fair to Good % PVC PU NYLONS 6 12 D D A A B A D C B A A 10% A C D C D A A B D D D B B B B D A A A A A A A D B A A A A D C D D D D D C B D C B A A A A A A A A B A B D D D A A A B A A B B D D D D C B D B C C A A A A A A A A A D B A A B B A A B CHEMICAL % Ferric Nitrate Ferric Sulfate Ferrous Chloride Ferrous Sulfate Flourochlorohydrocarbons Formaldehyde Formalin Formamide Formic Acid Formic Acid Formic Acid Freon Freon 12 Freons Fuel Oil Furfurol B B 40% D B 85% 10% 40% A D C D B C A C A A A A C C B B B A 40% 1% 10% C 70% C A A A A C B B D C D A A A B B B C C C A A A B A B A A A A A A A A A A A A A A C D B C C D D C D C A B C D B D B A A A D A A C A A A B B B B B D C D B B B B B A < 2% > 2% 40% 2% 30% 10% < 5% A B C B C B 20% 20% C D B PVC- Polyvinyl chloride PU- Polyurethane 159 NYLONS 6 12 B H Heptachlor in Petroleum Solvents Heptane Hexane Hydraulic Fluid Hydraulic Fluids - Ester Base Hydraulic Fluids-Petroleum Base Hydrazine Hydrobromic Acid Hydrocarbon Oil Hydrochloric Acid Hydrochloric Acid Hydrochloric Acid Hydrocyanic Acid Hydrofluoric Acid Hydrofluoric Acid Hydrofluoroboric Acid Hydrofluorosilicic Acid Hydrogen Hydrogen Chloride Hydrogen Chloride Hydrogen Fluoride Hydrogen Peroxide Hydrogen Peroxide Hydrogen Peroxide Hydrogen Sulfide Hydrolodic Acid C- Fair to Limited D- Unsatisfactory PU A A A G Gallic Acid Gasoline - 100 Octane Glycerine Glycol Glycolic Acid Grease Green Sulfate Liquor I Ink Iodine Solution Iron Salts - Acid Soln. Iron Salts - Neut. Soln. Isooctane Isopropanal Isopropyl Acetate Isopropyl Alcohol PVC B B T&B Conduit Fittings Conduit—Chemical Resistance Guide CHEMICAL % PVC J P-4 Oil Jet Fuels (JP-3,4, and 5) C K Kerosene Ketones C D L Lacquer Thinners Lactic Acid Lactic Acid Lactic Acid Lanolin Lead Acetate Lead Salts Linseed Oil Lox Lubricating Oils, Greases, Soaps NYLONS 6 12 B A A D 50% 5% 90% B C B D A B A B A A A A A B A A B B B A B A A B A D A C A B D C D D D A D A A A A A A A A A B D D A B A A C A A B A A A A B B C D A A A D A D A A D D A B B A A A A A A A D B A A A A D A A A A A O Octane Oil of Turpentine A- Good to excellent B- Fair to Good 10% A D A B D <1 PPM Pentachlorophenol in Oil Pentane Perchloric Acid Perchloroethylene Petroleum Petroleum Ether Petroleum Spirits Phenol Phenyl Ethyl Alcohol Phosphoric Acid Phosphoric Acid PVC PU D D A A B D C D B 10% 50% 85% D D B D B C- Fair to Limited D- Unsatisfactory A A A A A A C B C C C C B C A A A A C B A A A A B A A A A D A A A D A A A A A B A A D D A A A A A A A A A A A A A A A A A A B A B 50% 10% 10% 1% B 10% A B B C B D D C B A A C D B B B D B 10% 10% 10% PVC- Polyvinyl chloride PU- Polyurethane 160 A A R Resorcinol Ritchfield “A” Weed Killer S SEA No. 10 Oil Salicylic Acid Salt Seawater Silicic Acid Silicone Oil Silver Nitrate Silver Salts Skydrol Oil - Type B Soap Soap Solution Sodium Acetate Sodium Bicarbonate Sodium Bisulfite Sodium Borate Sodium Bromide A A A D B Plasticizers (Phthalates, Phosphates) Polyester Resin with Styrene Potash Potassium Bromide 10% Potassium Chlorate 7% Potassium Chlorate 5% Potassium Cyanide Potassium Hydroxide Potassium Hydroxide Potassium Iodide Potassium Nitrate Potassium Permanganate Potassium Salts Potassium Sulfate Propane Propanol Propyl Alcohol Propylene Glycol Pydraul Pydraul Oil Pyridine NYLONS 6 12 B C Pitch Nitromethane Oleic Acid Oleum Oxalic Acid Oxygen Oxygen - Liquid Ozone % Paraffin Oil Phosphoric Acid Photographic Developer Phthalates A C C D 10% 35% 70% CHEMICAL P Paint Paint Thinners Palmitic Acid Paper Chemicals C M MIL-D-5606 Oil MIL-L-7808 Oil Magnesium Chloride Magnesium Hydroxide 10% Magnesium Salts 10% Magnesium Sulfate Malathion 50 in Aromatics Malic Acid Mercury Mercury Salts Methanol Methyl Acetate Methyl Alcohol Methyl Bromide Methylene Chloride Methyl Ethyl Ketone Mineral Oil Monochlorobenzene Motor Fuels Motor Oil 20W Muriatic Acid (See Hydrochloric Acid) N Naphtha Naphthalene Natural Gas Nickel Salts Nitric Acid Nitric Acid Nitric Acid Nitric Acid Nitrobenzene Nitrogen PU B B B B T&B Conduit Fittings Conduit—Chemical Resistance Guide CHEMICAL Sodium Carbonate Sodium Carbonate Sodium Chlorate Sodium Chloride Sodium Chlorite Sodium Cyanide Sodium Dichromate Sodium Ferrocyanide Sodium Fluoride Sodium Hydrosulfiite Sodium Hydroxide Sodium Hydroxide Sodium Hydroxide Sodium Hypochlorite Sodium Nitrate Sodium Nitrate Sodium Nitrite Sodium Perborate Sodium Phosphate Sodium Silicate Sodium Sulfate Sodium Sulfide Sodium Sulfite Sodium Thiosulfite Solvent Naphtha Solvesso Stoddard Solvent Styrene Sulfur Sulfur Dioxide Sulfur Dioxide (Liquid) Sulfuric Acid Sulfuric Acid Sulfuric Acid Sulfuric Acid Sulfuric Acid Sulfuric Acid Sulfurous Acid T Tall Oil Tallow Tannic Acid Tar Tartaric Acid Tea Tetra Ethyl Lead Tetra Hydro Furan Tetraline Thionyl Chloride Tin Salts Titanium Salts Toluene Toluol Transformer Oil Transmission Oil Trichloroethane Trichlorethylene Trichloroacetic Acid Trichloroethylene Tricresyl Phosphate Tricresyl Phosphate (Skydrol) Triethanol Amine Trisodium Phosphate Tung Oil Turpentine % PVC PU NYLONS 6 12 B 10% B B 5% A 40% 50% 5% A A A C A C B B B B B B A A C B A C B A A B A A A A A A A A A A A A A C A B D D B B D C A B 10% 5% 5% 10% B 10% 10% 10% B D D D <5% % U Urea B 20% V Varnish Varsol Vaseline Vegetable Oils and Juices Vinegar Vinyl Chloride A D B D D B B D C B D D C C A A A A A A A A A A D A A D A A A A B B C B D C B A A A A B A A A A A A A B D A A D B X Xylene Xylols D D C A A A A B B B A A B B Z Zinc Chloride Zinc Sulfate 10% CHEMICAL Resistance Chart - Type ATX Thermoplastic Rubber jacket Test Method ASTM #2 OIL Brake Fluid D D D NYLONS 6 12 D Ethylene Glycol 10% PU W Water Water 23°C Water 70°C Wax Wood Preservatives D A PVC B D 2% 10% 20% 25% 50% 98% CHEMICAL Methanol Silicone Oil 5 % Salt Water Vegetable Oil Animal Oil 10W-40 Motor Oil Gasoline Transmission Oil Freon2 UL - 1581 ASTM D - 471 ASTM D - 471 ASTM D - 471 ASTM D - 471 ASTM D - 471 ASTM D - 471 ASTM D - 471 ASTM D - 471 ASTM D - 471 ASTM D - 471 ASTM D - 471 D D D B B PVC- Polyvinyl chloride PU- Polyurethane A 90 66 45 80 95 95 100 80 60 70 50 40 50 93 98 70 40 90 90 90 80 100 70 75 55 35 50 84 N/A N/A N/A -7 2 0 -14 1 N/A N/A 25 17 32 N/A This information is provided as a guide line only. No guarantee is implied. Results are based on controlled laboratory tests and not on installed end-product applications. Electri-Flex recommends that samples be exposed to and observed in actual service conditions for extreme or unusual situations. A- Good to excellent B- Fair to Good C- Fair to Limited D- Unsatisfactory B 7 days/60°C 4 days/100°C 18 hrs/120°C 72 hrs/100°C 72 hrs./100°C 72 hrs./ 100°C 72 hrs./100°C 72 hrs./100°C 18 hrs./120°C 18 hrs./120°C 72 hrs./100°C 72 hrs./ 100°C 72 hrs./100°C 72 hrs./50°C % Tensile % % Volume Strength Elongation Increase A 161 Alphanumeric Index Catalogue Number ABR038-15 ABR038-30 ABR038-300 ABR038-8 ABR050-15 ABR050-30 ABR050-300 ABR050-8 ABR075-15 ABR075-150 ABR075-30 ABR075-8 ABR100-120 ABR100-15 ABR125-120 ABR125-15 ABR150-8 ABR150-90 ABR200-45 ABR200-8 ABR250-8 ABR300-8 ABR350-8 ABR400-8 ABRH038 ABRH050 ABRH075 ABRH100 ABRH125 ABRH150 ABRH200 ABRH250 ABRH300 ABRH400 ABRH716 ACEA038 ACEA038-60 ACEA050 ACEA050-30 ACEA050-300 ACEA075 ACEA075-150 ACEA075-30 ACEA075-45 ACEA100 ACEA100-120 ACEA100-30 ACEA125 ACEA125-15 ACEA125-75 ACEA150 ACEA150-15 ACEA150-45 Page Number 143 143 143 143 143 143 143 143 143 143 143 143 143 143 143 143 143 143 143 143 143 143 143 143 143 143 143 143 143 143 143 143 143 143 143 138 138 138 138 138 138 138 138 138 138 138 138 138 138 138 138 138 138 Catalogue Number Page Number 138 138 138 138 138 138 138 138 138 138 138 136 136 136 136 136 136 136 136 136 136 136 136 136 136 136 136 136 136 136 136 136 136 135 135 135 135 135 135 135 135 135 135 135 135 135 135 135 135 135 135 135 135 ACEA200 ACEA200-15 ACEA200-30 ACEA250 ACEA250-8 ACEA300 ACEA300-8 ACEA400 ACEA400-8 ACEA500 ACEA600 ALT038-150 ALT038-30 ALT038-300 ALT050-150 ALT050-30 ALT050-300 ALT075-150 ALT075-30 ALT075-300 ALT100-120 ALT100-30 ALT125-15 ALT125-60 ALT150-15 ALT150-45 ALT200-15 ALT200-30 ALT250-8 ALT350-8 ALT400-8 ALT500-8 ALT600-8 AT038-150 AT038-30 AT038-300 AT050-150 AT050-30 AT050-300 AT075-150 AT075-30 AT075-300 AT100-120 AT100-30 AT125-15 AT125-60 AT150-15 AT150-45 AT200-15 AT200-30 AT250-8 AT300-8 AT350-8 162 Catalogue Number AT400-8 AT500-8 AT600-8 ATLA038-150 ATLA038-30 ATLA038-300 ATLA050-150 ATLA050-30 ATLA050-300 ATLA075-150 ATLA075-30 ATLA075-300 ATLA100-120 ATLA100-30 ATLA125-15 ATLA125-60 ATLA150-15 ATLA150-45 ATLA200-15 ATLA200-30 ATLA250-8 ATLA300-8 ATLA350-8 ATLA400-8 ATX038-150 ATX038-30 ATX038-300 ATX050-150 ATX050-30 ATX050-300 ATX075-150 ATX075-30 ATX075-300 ATX100-120 ATX100-30 ATX125-15 ATX125-60 ATX150-15 ATX150-45 ATX200-15 ATX200-30 ATX250-8 ATX300-8 ATX400-8 BG050-14-20 BG050-14-4 BG075-14-20 BG075-14-4 BG100-14-20 BG100-14-4 BG125-14-20 BG150-14-20 BG200-14-20 Page Number 135 135 135 134 134 134 134 134 134 134 134 134 134 134 134 134 134 134 134 134 134 134 134 134 135 135 135 135 135 135 135 135 135 135 135 135 135 135 135 135 135 135 135 135 14 14 14 14 14 14 14 14 14 Alphanumeric Index Catalogue Number BG250-14-20 BG250-6-40 BG300-14-20 BG300-6-40 BG350-14-20 BG350-6-40 BG400-14-20 BG400-6-40 BG500-14-20 BG500-6-40 BG600-14-20 BG600-6-40 BGA050-14-20 BGA050-14-4 BGA075-14-20 BGA075-14-4 BGA100-14-20 BGA100-14-4 BGA125-14-20 BGA150-14-20 BGA200-14-20 BGA250-14-20 BGA250-6-40 BGA300-14-20 BGA300-6-40 BGA350-14-20 BGA350-6-40 BGA400-14-20 BGA400-6-40 BGA500-14-20 BGA500-6-40 BGA600-14-20 BGAT600-6-40 BR038 BR038-15 BR038-30 BR038-300 BR038-75 BR038-8 BR050 BR050-15 BR050-30 BR050-300 BR050-8 BR075 BR075-15 BR075-150 BR075-30 BR075-8 BR100 BR100-120 BR100-15 BR125 Page Number 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 14 142 142 142 142 142 142 142 142 142 142 142 142 142 142 142 142 142 142 142 142 Catalogue Number Page Number 142 142 142 142 142 142 142 142 142 142 142 142 142 142 142 142 132 132 132 132 132 132 132 132 132 132 132 132 132 132 132 132 132 132 132 132 132 132 132 132 132 81 81 81 81 81 81 81 81 81 81 81 81 BR125-120 BR125-15 BR150 BR150-8 BR150-90 BR200 BR200-45 BR200-8 BR250 BR250-8 BR300 BR300-8 BR350 BR350-8 BR400 BR400-8 CBLA038-150 CBLA038-30 CBLA038-300 CBLA050-150 CBLA050-30 CBLA050-300 CBLA075-150 CBLA075-30 CBLA075-300 CBLA100-120 CBLA100-30 CBLA125-15 CBLA125-60 CBLA150-15 CBLA150-45 CBLA200-15 CBLA200-30 CBLA250-8 CBLA250-80 CBLA300-50 CBLA300-8 CBLA350-50 CBLA350-8 CBLA400-30 CBLA400-8 CC-ISO-16-G CC-ISO-20-G CC-ISO-25-G CC-ISO-32-G CC-NPT1-B CC-NPT1-G CC-NPT12-B CC-NPT12-G CC-NPT34-B CC-NPT34-G CC-NPT38-B CC-NPT38-G 163 Catalogue Number CC-PG11-G CC-PG135-G CC-PG16-G CC-PG21-G CC-PG29-G CC-PG36-G CC-PG7-G CC-PG9-G CCG10-30 CCG11-30 CCG12-30 CCG13-15 CCG14-15 CCG15-15 CC11-38 CC11-38P CC135-50 CC16-50 CC21-75 CC29-100 CC36-125 CC42-150 CEA038-30 CEA038-300 CEA050-30 CEA050-300 CEA075-150 CEA075-30 CEA100-120 CEA100-30 CEA125-15 CEA125-60 CEA150-15 CEA150-45 CEA200-15 CEA200-30 CEA250-8 CEA300-8 CEA400-8 CEA500-8 CEA600-8 CF-10 CF-11 CF-12 CF-13 CF-14 CF-140 CF-140A CF-15 CF-20 CF-21 CF-22 CF-22TB Page Number 81 81 81 81 81 81 81 81 149 149 149 149 149 149 82 82 82 82 82 82 82 82 137 137 137 137 137 137 137 137 137 137 137 137 137 137 137 137 137 137 137 150 150 150 150 150 150 150 150 150 150 150 150 Alphanumeric Index Catalogue Number CF-23 CF-24 CF-25 CF-350 CF-516 CF-516A CFF-17 CFF-27 CFF-350A CFM-10 CFM-11 CFM-12 CFM-13 CFM-14 CFM-15 CFM-20 CFM-21 CFM-22 CFM-23 CFM-24 CFM-25 CFM-516 CFM-516A CFP-10 CFP-11 CFP-12 CFP-13 CFP-14 CFP-15 CFP-20 CFP-21 CFP-22 CFP-23 CFP-24 CFP-25 CI-1703PL CG11-38 CG11-38P CG135-50 CG16-50 CG21-75 CG29-100 CG36-125 CG42-150 CL10-30 CL11-30 CL12-30 CL13-15 CL14-15 CL140-30 CL15-15 CL516-30 CLFR10-30 Page Number 150 150 150 151 150 150 151 151 151 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 150 81 82 82 82 82 82 82 82 82 148 148 148 148 148 148 148 148 149 Catalogue Number Page Number CLFR11-30 CLFR12-30 CLFR13-15 CLFR14-15 CLFR15-15 149 149 149 149 149 CLFR516-30 CLL10-30 CLL11-30 CLL12-30 CLL13-15 CLL14-15 CLL15-15 CLL17-10 CLL350-10 CLR10-30 CLR11-30 CLR12-30 CLR13-15 CLR14-15 CLR15-15 CLR17-10 CLR350-10 CSA038-150 CSA038-30 CSA038-300 CSA050-150 CSA050-30 CSA050-300 CSA075-150 CSA075-30 CSA075-300 CSA100-120 CSA100-30 CSA125-15 CSA125-60 CSA150-15 CSA150-45 CSA200-15 CSA200-30 CSA250-8 CSA300-8 CSA400-8 CXP722 CXP723 CXP724 CXP725 CXP726 CXP727 CTC-10 CTC-11 CTC-12 CTC-13 149 148 148 148 148 148 148 148 148 149 149 149 149 149 149 149 149 133 133 133 133 133 133 133 133 133 133 133 133 133 133 133 133 133 133 133 133 82 82 82 82 82 82 151 151 151 151 164 Catalogue Number Page Number CTC-140 CTC-516 EF038-150 EF038-30 EF038-300 EF050-150 EF050-30 EF050-300 EF075-150 EF075-30 EF075-300 EF100-120 EF100-30 EF125-15 EF125-75 EF150-15 EF150-45 EF200-15 EF200-30 EMS038-150 EMS038-30 EMS050-150 EMS050-30 EMS075-150 EMS075-30 EMS100-120 EMS100-30 EMS125-15 EMS125-60 EMS150-15 EMS150-45 EMS200-15 EMS200-30 151 151 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 141 141 141 141 141 141 141 141 141 141 141 141 141 141 EMS250-8 EMS300-8 EMS400-8 EMSP038-150 EMSP038-30 EMSP050-150 EMSP050-30 EMSP075-150 EMSP075-30 EMSP100-120 EMSP100-30 FTA-U12516 FTA-U15516 FTA-U1810 FTA-U18516 FTA-U2310 FTA-U2311 FTA-U2312 FTA-U2411 141 141 141 141 141 141 141 141 141 141 141 152 152 152 152 152 152 152 152 Alphanumeric Index Catalogue Number FTA-U2911 FTA-U2912 FTA-U3411 FTA-U3412 FTA-U3512 GR1W GR2W GR3W GR4W GR5W H050-TB H050BHD H050CAP H050GR-C H050TBF H050TBH H075-TB H075BHD H075CAP H075GR-C H075TBF H075TBH H100-TB H100BHD H100CAP H100GR-C H100TBF H100TBH H125-TB H125BHD H125CAP H125GR-C H125TBF H125TBH H150-075ORGR-TB H150-100ORGR-TB H150-125ORGR-TB H150-TB H150BHD H150CAP H150GR-C H150TBF H150TBH H200-TB H200BHD H200CAP H200GR-C H200TBF H200TBH H250-200ORGR-TB H250-TB H250BHD H250CAP Page Number 152 152 152 152 152 97 97 97 97 97 28 30 31 29 30 30 28 30 31 29 30 30 28 30 31 29 30 30 28 30 31 29 30 30 31 31 31 28 30 31 29 30 30 28 30 31 29 30 30 31 28 30 31 Catalogue Number Page Number 29 28 30 31 29 28 30 31 29 28 30 31 29 28 30 31 29 28 30 31 29 78 78 78 78 78 78 78 29 29 29 29 29 29 29 29 29 29 29 29 131 131 131 131 131 131 131 131 131 131 131 131 131 H250GR-C H300-TB H300BHD H300CAP H300GR-C H350-TB H350BHD H350CAP H350GR-C H400-TB H400BHD H400CAP H400GR-C H500-TB H500BHD H500CAP H500GR-C H600-TB H600BHD H600CAP H600GR-C HLT050DATA HLT050 HLT075 HLT100 HLT125 HLT150 HLT200 L050GR-C L075GR-C L100GR-C L125GR-C L150GR-C L200GR-C L250GR-C L300GR-C L350GR-C L400GR-C L500GR-C L600GR-C LA038-150 LA038-30 LA038-300 LA050-150 LA050-30 LA050-300 LA075-150 LA075-30 LA075-300 LA100-120 LA100-30 LA125-15 LA125-60 165 Catalogue Number Page Number LA150-15 LA150-45 LA200-15 LA200-30 LA250-8 LA250-80 LA300-50 LA300-8 LA350-50 LA350-8 LA400-30 LA400-8 LAS038-150 LAS038-30 LAS050-150 LAS050-30 LAS075-150 LAS075-30 LAS100-120 LAS100-30 LN501 LN502 LN503 LN-PG11-G LN-PG16-G LN-PG135-G LN-PG21-G LN-PG29-G LN-PG36-G LN-PG7-G LN-PG9-G LN-ISO16-G LN-ISO20-G LN-ISO25-G LN-ISO32-G LNMP038-150 LNMP038-300 LNMP038-75 LNMP050-150 LNMP050-300 LNMP050-60 LNMP075-150 LNMP075-50 LNMP100-120 LNMP100-30 LNMP125-30 LNMP125-60 LNMP150-15 LNMP150-45 LNMP200-15 LNMP200-30 131 131 131 131 131 131 131 131 131 131 131 131 140 140 140 140 140 140 140 140 81 81 81 81 81 81 81 81 81 81 81 81 81 81 81 146 146 146 146 146 146 146 146 146 146 146 146 146 146 146 146 LOR038-150 130 Alphanumeric Index Catalogue Number LOR038-30 LOR038-300 LOR050-150 LOR050-300 LOR050-50 LOR075-150 LOR075-30 LOR075-300 LOR100-120 LOR100-30 LOR125-15 LOR125-60 LOR150-15 LOR200-15 LOR250-8 LOR300-8 LOR350-8 LOR400-8 LOR500-8 LOR600-8 LT025-75 LT032-75 LT038-150 LT038-30 LT038-300 LT050-150 LT050-30 LT050-300 LT075-150 LT075-30 LT075-300 LT100-120 LT100-30 LT100M LT100P LT125-15 LT125-75 LT125M LT125P LT150-15 LT150-45 LT150M LT150P LT200-15 LT200-30 LT200M LT200P LT250-8 LT250-80 LT300-50 LT300-8 LT350-50 LT350-8 Page Number 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 130 129 129 129 129 129 129 129 129 129 129 129 129 129 109 108 129 129 109 108 129 129 109 108 129 129 109 108 129 129 129 129 129 129 Catalogue Number Page Number 109 110 108 110 129 129 109 108 109 108 109 108 109 108 109 110 108 109 110 108 109 110 108 129 109 110 108 110 129 109 110 108 110 109 108 109 108 109 108 109 108 109 110 108 110 109 110 108 110 109 110 108 105 LT38M LT38M-ISO20 LT38P LT38P-ISO20 LT400-30 LT400-8 LT4100M LT4100P LT4125M LT4125P LT4150M LT4150P LT4200M LT4200P LT438M LT438M-ISO20 LT438P LT450M LT450M-ISO20 LT450P LT475M LT475M-ISO25 LT475P LT500-8 LT50M LT50M-ISO20 LT50P LT50P-ISO20 LT600-8 LT75M LT75M-ISO25 LT75P LT75P-ISO25 LT9100M LT9100P LT9125M LT9125P LT9150M LT9150P LT9200M LT9200P LT938M LT938M-ISO20 LT938P LT938P-ISO20 LT950M LT950M-ISO20 LT950P LT950P-ISO20 LT975M LT975M-ISO25 LT975P LTA03810 166 Catalogue Number LTA03814 LTA05014 LTA05016 LTA05018 LTA07516 LTA07518 LTA07520 LTA10020 LTA10024 MB-10TB MB-11 MB-12 MB-13 MB-14 MB-140 MB-15 MB-516 MSA05014 MSA05016 MSA05018 MSA07516 MSA07518 MSA07520 MSA10020 MSA10024 MSA10032 MSA10036 NMC038TB NMC050-1000TB NMC050TB NMC075-500TB NMC075TB NMC100TB NMC125TB NMC150TB NMC200TB NMT038TB NMT050TB NMT075TB NMT100TB NMT125TB NMT150TB NMT200TB PG11-38 PG16-50 PG21-75 PG29-100 PG29-125 PG36-125 PG36-150 PSA-M12140 PSA-M12516 PSA-M130140 Page Number 105 105 105 105 105 105 105 105 105 152 152 152 152 152 152 152 152 106 106 106 106 106 106 106 106 106 106 147 147 147 147 147 147 147 147 147 147 147 147 147 147 147 147 82 82 82 82 82 82 82 152 152 152 Alphanumeric Index Catalogue Number PSA-M18140 PSA-M18516 PSA-M30516 PSA-M8140 SC4-KIT SC65 SL038-75 SL050-45 SL050M-45 SL075-30 SL100-15 SL100M-15 SL140-75 SL316-75 SL340-45 SL380-75 SL516-75 SL716-75 SL916-45 TCF050-27AL TCF050-40AL TCF050-54AL TCF050-67AL TCF050-78AL TCF075-40AL TCF075-54AL TCF075-67AL TCF075-78AL TCF075-88AL TCF100-100AL TCF100-109AL TCF100-78AL TCF100-88AL TCF125-109AL TCF125-128Al TCF125-147AL TCF150-115AL TCF150-140AL TCF150-165AL TCF200-153AL TCF200-186AL TCF200-219AL TCF250-252AL TCF300-278AL TCF300-304AL TCF300-330AL TR-10-516 TR-11-10 TR-11-516 TR-12-10 TR-12-11 TR-12-516 TR-13-11 Page Number 152 152 152 152 78 78 144 144 144 144 144 144 144 144 144 144 144 144 144 77 77 77 77 77 77 77 77 77 77 77 77 77 77 77 77 77 77 77 77 77 77 77 77 77 77 77 151 151 151 151 151 151 151 Catalogue Number Page Number 151 18 18 18 18 18 18 18 18 18 18 145 145 145 145 145 145 145 145 145 144 144 144 144 144 144 144 144 144 144 145 145 145 145 145 145 93 93 93 93 93 93 93 93 93 93 80 80 80 80 80 80 80 TR-516-140 TRIB-100 TRIB-125 TRIB-150 TRIB-200 TRIB-250 TRIB-300 TRIB-350 TRIB-400 TRIB-50 TRIB-75 UG100-15 UG120-15 UG125-15 UG150-15 UG200-15 UG250-15 UG300-15 UG340-15 UG380-15 USL120 USL120-75 USL380 USL380-75 USL516 USL516-75 USL716 USL716-75 USL916 USL916-75 VJC038-30 VJC050-30 VJC050M-30 VJC075-30 VJC100-30 VJC100M-30 WMG-LT1 WMG-LT10 WMG-LT2 WMG-LT3 WMG-LT4 WMG-LT5 WMG-LT6 WMG-LT7 WMG-LT8 WMG-LT9 WMG-PC1 WMG-PC10 WMG-PC11 WMG-PC12 WMG-PC13 WMG-PC14 WMG-PC15 167 Catalogue Number WMG-PC16 WMG-PC17 WMG-PC18 WMG-PC19 WMG-PC2 WMG-PC20 WMG-PC21 WMG-PC22 WMG-PC3 WMG-PC4 WMG-PC5 WMG-PC6 WMG-PC7 WMG-PC8 WMG-PC9 ZHLA038-150 ZHLA038-30 ZHLA038-300 ZHLA050-150 ZHLA050-30 ZHLA050-300 ZHLA075-150 ZHLA075-30 ZHLA075-300 ZHLA100-120 ZHLA100-30 ZHLA125-15 ZHLA125-60 ZHLA150-15 ZHLA150-45 ZHLA200-15 ZHLA200-30 ZHLA250-8 ZHLA300-8 ZHLA350-8 ZHLA400-8 100BP 100TB 106 107 108 109 110-TB 111 112-TB 113-TB 114 115-TB 1210C 1211C 1212C 1213C 1214TB Page Number 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 139 139 139 139 139 139 139 139 139 139 139 139 139 139 139 139 139 139 139 139 139 126 126 11 11 11 11 11 11 11 11 11 11 42 42 42 42 42 Alphanumeric Index Catalogue Number 1215TB 1216TB 122 1222 1223 1224 1225 1226 1227 1228 1229 122AL 123 1230 1231 1232 123AL 124 1244 1245 1246 1247 124AL 125-TB 1250-TB 1251 1252 1253 1254 1255 1256 1257 1258 125AL 126 1261 1262 1263 126AL 127 1275 1275AL 1275CR 1276 1276AL 1276CR 1277 1277AL 1277CR 1278 1278AL 1278CR 1279 Page Number 42 42 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 39 39 39 39 16 16 39 39 39 39 39 39 39 39 39 16 16 39 39 39 16 16 41 41 42 41 41 42 41 41 42 41 41 42 41 Catalogue Number Page Number 1279AL 1279CR 127AL 128 1280 1280AL 1280CR 1281 1281AL 1281CR 1282 1282AL 1283 1283AL 1284 1284AL 1285 1285AL 1286 1286AL 1287 1287AL 1288 1288AL 128AL 129 129AL 12GR-TB 130-TB 130AL 131-TB 131AL 132-TB 133-TB 133AL 134-TB 1341 1344 1345 1346 1347 134AL 1350 1350AL 1350CR 1351 1351AL 1351CR 1352 1352AL 1352CR 1353 1353AL 41, 41, 41, 41, 44, 44, 44, 44, 168 41 42 16 16 41 41 42 41 41 42 59 41 59 41 59 41 59 41 41 41 41 41 41 41 16 16 16 97 16 16 16 16 16 16 16 16 87 87 87 87 87 16 59 44 44 59 44 44 59 44 44 59 44 Catalogue Number 1353CR 1354 1354AL 1354CR 139 140 141 141AL 141SL 141SST 142-TB 142AL 142SL 142SST 143 143AL 143SL 143SST 144 1440 1441 1442 1443 144AL 144SL 144SST 145 1451 1452 1453 1454 1455 1456 145AL 145SL 145SST 146-TB 1460 1461 1462 1463 1464 1465 146AL 146SL 146SST 147 147AL 147SST 1470-TB 1471 1472 1473 Page Number 44 44, 59 44 44 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 39 39 39 39 11 11 11 11 20 20 20 20 20 20 11 11 11 11 21 21 21 21 21 21 11 11 11 11 11 11 21 21 21 21 Alphanumeric Index Catalogue Number 1474 1475 1476 1477 1478 1479 148 148AL 148SST 149 149AL 149SST 150 150AL 150SST 151 151AL 151SST 152 152AL 152SST 153 153AL 153SST 1942 1943 1944 1945 1946 1947 1948 1949 1950 1951 1953 1954 1GR-TB 2111 2116 2200 2201 2202 2203 2204 2205 2206-TB 2207-TB 2208-TB 2209 2210 2211 2213 2214 Page Number 21 21 21 21 21 21 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 11 23 23 23 23 23 23 23 23 23 23 23 23 97 86 86 68 68 68 68 68 68 68 68 68 68 68 68 68 68 Catalogue Number 2215 2216 2217 2218 2219 222-TB 2220-TB 2221 2222 2223 223-TB 2232 2233 2234 2237 2238 2239 224 225-TB 2250 2251 2252 2253 2254 2255 2256 2257 2258 226 2267 2268 2269 227 2270 2271 2272 2273 2274 2275 2276 2277 2278 2279 228-TB 2280 2281 2282 2283 2284 2285 2286 229-TB 230-TB 169 Page Number Catalogue Number Page Number 68 68 68 68 68 17 68 68 68 68 17 86 86 86 86 86 86 17 17 67 67 67 67 67 67 67 67 67 17 67 67 67 17 67 67 67 67 67 67 67 67 67 67 17 67 67 67 67 67 67 67 17 17 231 232 233 234 2432 2433 2434 2438 2439 2442 2443 2446 2447 2448 2449 2450 2454 249 2516 2517 2518 2519 252 2520 2520-2 2521 2522 2523 2524 2525 253-TB 2530-2 2530 2531 2531-2 2531-3 2532 2534 2535 2536 254-C 2540-3 2540-4 2541-2 2541-3 2541 2542 2542-2 2544 2545 2546 2547 2548 17 17 17 17 86 86 86 86 86 86 86 86 86 86 86 86 86 117 66 66 66 66 117 66 69 66 66 66 66 66 117 69 66 66 69 69 66 66 66 66 117 69 69 69 69 66 66 69 66 66 66 66 66 Alphanumeric Index Catalogue Number 2549 255 2555-2 2556 2557 2558 2559 256 2562 2563 2564 2565 257 2573 2574 2575 2576 2577 258 2584 2585 2586 2587 259 2592 2593 2594 2595 2596 2631 2632 2633 2634 2637 2638 2639 2640 2641 265 266-C 267 2671 2672 2673 2674 2675 2676 2677 2678 268-C 2680 2681 2682 Page Number 66 117 69 66 66 66 66 117 66 66 66 66 117 66 66 66 66 66 117 66 66 66 66 117 66 66 66 66 66 69 69 69 69 69 69 69 69 69 117 117 117 63, 79 79 79 79 79 79 79 63, 79 117 63, 79 79 79 Catalogue Number Page Number 79 79 63, 79 63, 79 63, 79 63, 79 117 79 79 79 79 79 63, 79 63, 79 117 63, 79 63, 79 63, 79 63 79 63, 79 63, 79 63, 79 63, 79 63, 79 117 117 117 117 117 117 117 87 87 87 118 73 73 70 72 63, 75 70 73 70 72 63, 75 70 73 70 72 63, 75 70 73 2683 2684 2685 2686 2687 2688 269 2690 2691 2692 2693 2694 2696 2699 270 2702 2703 2704 2705 2705TB 2706 2707 2708 2709 2710 272 273-TB 274 275 276 277 279 2827 2828 2829 291-C 2918SST 2919SST 2920 2920AL 2920NM 2920S 2920SST 2921 2921AL 2921NM 2921S 2921SST 2922 2922AL 2922NM 2922S 2922SST 170 Catalogue Number 2930 2930AL 2930NM 2930S 2930SST 2931 2931AL 2931NM 2931S 2931SST 2932 2932AL 2932NM 2932S 2932SST 2940 2940AL 2940NM 2940S 2940SST 2941 2941AL 2941NM 2941S 2941SST 2942 2942AL 2942NM 2942S 2942SST 300-TBC 302-C 304 306 308 310 3110-C 3112 3115 3117 3118 3119 312 3120 3121 3122 3123 3124 3125 3130-C 3132 3135 3137 Page Number 70 72 63, 75 70 73 70 72 63, 75 70 73 70 72 63, 75 70 73 70 72 63, 75 70 73 70 72 63, 75 70 73 70 72 63, 75 70 73 115 115 115 115 115 115 115 115 115 115 115 115 115 115 115 115 115 115 115 116 116 116 116 Alphanumeric Index Catalogue Number 3138 3139 314 3140 3141 3142 3143 3144-TB 316 3201 3202 321-C 3210 3211 3212 3213 3214 3215 323 325 326-TB 327 328 329 330-TB 3300 3301-C 3302 3302M-C 3303-C 3303M 3304 3304M 3305 3305M 3306 3306M 3307 3307M 3308 3309 331 3310 3311 3312-C 3321 3322 3323 3324 3325 3326 3327 3328-TB Page Number 116 116 115 116 116 116 116 116 115 124 124, 125 116 19 19 19 19 19 19 116 116 116 116 116 116 116 124, 125 118 123 123 123 123 123 123 123 123 123 123 123 123 123 123 116 123 123 118 99 99 99 99 99 99 99 99 Catalogue Number Page Number 99 99 99 99 99 99 99 99 99 99 99 124, 125 99 99 99 99 99 99 99 99 99 99 99 97 12 12 12 12 12 12 12 12 12 12 12 12 26 26 40 40 40 40 40 40 40 40 40 40 26 26 40 40 40 3329 3331 3341 3342 3343 3344-TB 3345 3346 3347 3348-TB 3349 3350 3352 3361 3362 3363 3364 3365 3366 3367 3368 3369 3371 34GR-TB 3650 3651 3652 3653 3654 3655 3656 3657 3658 3659 3661 3662 370 370AL 3700 3701 3702 3703 3704 3705-TB 3706 3707 3708 3709 371 371AL 3710 3711 3712 171 Catalogue Number 3713 3714 3715-TB 3716 3717 3718 372 372AL 3720-TB 3721-TB 3722-TB 3723 3724-TB 3725 3726 373 373AL 3730-TB 3731-TB 3732 3733-TB 3734-TB 3735-TB 3736 374 374AL 3740 3741 3742 3743-TB 3744-TB 3745 3746-TB 375 375AL 376 377 378 379-TB 381-TB 382-TB 3861 3862 3863 3864 3865 3866 3870-TB 3871-TB 3872 3873 3874 3875 Page Number 40 40 40 40 40 40 26 26 102 102 102 102 102 102 102 26 26 103 103 103 103 103 103 103 26 26 103 103 103 103 103 103 103 26 26 26 26 26 26 26 26 15 15 15 15 15 15 15 15 15 15 15 15 Alphanumeric Index Catalogue Number 3876 3877 3878 3879 3880 3881 3882 3883 3884 3886 3887 3889 38GR-TB 390 391 392 393 394 3993 3994 3995 3996 3998 3999 4-250TC 4-300TC 4-350TC 4-400TC 401 402 403-TB 404-TB 405-TB 407 408 409 41TB 410-TB 4159C 4160C 4161C 4162 4163 4164 4176 4177 4178 4179 4180 4181 42TB 422 423 Page Number 15 15 15 15 15 15 15 15 15 15 15 15 97 119 119 119 119 119 15 15 15 15 15 15 78 78 78 78 26 26 26 26 26 26 26 26 100 26 59 59 59 59 59 59 59 59 59 59 59 59 100 19 19 Catalogue Number Page Number 58 58 58 58 58 58 19 58 58 58 58 58 58 19 37 37 37 37 37 37 19 19 19 19 37 37 37 37 37 37 20 19 19 19 45 45 45 119 37 37 37 37 27 27 27 27 27 27 27 27 71 71 71 4230 4231 4232 4233 4234 4235 424 4240 4241-TB 4242 4243-TB 4244 4245 425 4250 4251 4252 4253 4254 4255 426-TB 427-TB 428-TB 429 4290 4291 4292 4293 4294 4295 430-TB 431 433 434 440-C 441 442 449C 460TB 461TB 462 463 485 486 487 488 489 490 491 492 4920 4921 4922 172 Catalogue Number 493 4932 4933 494 4960 4960AL 4960NM 4961 4961AL 4961NM 4962 4962AL 4970 4970AL 4970NM 4971 4971AL 4971NM 4972 4972AL 4972NM 4980AL 4981AL 4982AL 503-TB 504 505-TB 5120 5121-TB 5123 5220 5221 5223 5229 5231 5231AL 5231ALGR 5231GR 5232 5232AL 5232ALGR 5232GR 5233 5233AL 5233ALGR 5233GR 5234 5234AL 5234ALGR 5234GR 5235 5235AL 5235GR Page Number 27 71 71 27 71 72 63, 75 71 72 63, 75 71 72 71 72 63, 75 71 72 63, 75 71 72 63, 75 72 72 72 118 118 118 57 57 57 57 57 57 92 92 92 96 96 92 92 96 96 92 92 96 96 92 92 96 96 92 92 96 Alphanumeric Index Catalogue Number 5236 5236AL 5236GR 5237 5237AL 5237GR 5238 5238AL 5238GR 5239 5239AL 5239GR 5240 5240AL 5240GR 5241 5241GR 5242 5242GR 5243 5243GR 5244 5244GR 5245 5245GR 5246 5246GR 5247 5247GR 5248 5248GR 5249 5249GR 5250 5250GR 5251 5251AL 5251ALGR 5251GR 5252 5252AL 5252ALGR 5252GR 5253 5253AL 5253ALGR 5253GR 5254 5254AL 5254ALGR 5254GR 5255 5255AL Page Number 92 92 96 92 92 96 92 92 96 92 92 96 92 92 96 92 96 92 96 92 96 92 96 92 96 92 96 92 96 92 96 92 96 92 96 93 93 96 96 93 93 96 96 93 93 96 96 93 93 96 96 93 93 Catalogue Number Page Number 96 93 93 96 93 93 96 93 93 96 93 96 93 96 74-104 74-104 74-104 74-104 74-104 74-104 74-104 104 104 104 94 97 94 97 94 97 94 97 94 97 94 97 92 96 104 58 12 12 12 12 12 12 12 12 58 12 58 57 57 5255GR 5256 5256AL 5256GR 5257 5257AL 5257GR 5258 5258AL 5258GR 5259 5259GR 5260 5260GR 5261 5262 5263 5264 5265 5266 5267 5268 5269 5270 5271 5271GR 5272 5272GR 5273 5273GR 5274 5274GR 5275 5275GR 5276 5276GR 5285 5285GR 5299 530-TB 5302 5303 5304 5305 5306 5307 5308 5309 531 5311 532 5320 5321 173 Catalogue Number 5323 5330 5331 5331-HT 5331GR 5331SST 5332 5332-HT 5332GR 5332SST 5333 5333-HT 5333GR 5333SST 5334 5334-HT 5334GR 5334SST 5335 5335-HT 5335GR 5335SST 5336 5336-HT 5336GR 5336SST 5337 5337-HT 5337GR 5337SST 5338 5338-HT 5338GR 5339 5339-HT 5339GR 5340 5340-HT 5340GR 5341 5341GR 5341-HT 5341SST 5342 5342GR 5342-HT 5342SST 5343 5343GR 5343-HT 5343SST 5344 5344GR Page Number 57 92 92 91 96 74 92 91 96 74 92 91 96 74 92 91 96 74 92 91 96 74 92 91 96 74 92 91 96 74 92 91 96 92 91 96 92 91 96 92 96 91 74 92 96 91 74 92 96 91 74 92 96 Alphanumeric Index Catalogue Number 5344-HT 5344SST 5345 5345GR 5345-HT 5345SST 5346 5346GR 5346-HT 5346SST 5347 5347GR 5347-HT 5347SST 5348 5348GR 5349 5349GR 5350 5350GR 5351 5351GR 5351-HT 5351SST 5352 5352GR 5352-HT 5352SST 5353 5353GR 5353-HT 5353SST 5354 5354GR 5354-HT 5354SST 5355 5355GR 5355-HT 5355SST 5356 5356GR 5356-HT 5356SST 5357 5357GR 5357-HT 5357SST 5358 5358GR 5359 5359GR 5360 Page Number 91 74 92 96 91 74 92 96 91 74 92 96 91 74 92 96 92 96 92 96 93 96 91 74 93 96 91 74 93 96 91 74 93 96 91 74 93 96 91 74 93 96 91 74 93 96 91 74 93 96 93 96 93 Catalogue Number 5360GR 5361 5362 5363 5364 5365 5366 5367 5368 5369 5370 5385 5385GR 5386 5386GR 5420 5421 5423 5520 5521-TB 5523 5620 5621 5623 5710 5711 5712 5713 5714 5715 5716 5717 5718 586 587 600-TB 600AL-TB 601-TB 601AL-TB 602-TB 602AL-TB 603-TB 603AL-TB 604-TB 604AL-TB 605-TB 605AL 606-TB 606AL 607 607AL 608 608AL 174 Page Number Catalogue Number Page Number 96 94 94 94 94 94 94 94 94 94 94 92 96 92 96 57 57 57 57 57 57 57 57 57 103 103 103 103 103 103 103 103 103 16 16 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 609 609AL 610 610AL 611-TB 611AL 612 612AL 613 613AL 614-TB 614AL 615-TB 615AL 6209 6210 6211 6212 6214 6216 6218 6302 6303 6304 6305 6322 6323 6324 6325 65C 674 675 675AL 676 676AL 677 677AL 678 678AL 679 679AL 680-TB 680AL 681 681AL 682 682AL 683 683AL 684 684AL 685 685AL 40 40 40 40 40 40 40 40 40 40 40 40 40 40 126 126 126 126 126 126 126 102 102 102 102 102 102 102 102 119 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 38 Alphanumeric Index Catalogue Number 686 686AL 687 687AL 690TB 691TB 692TB 693TB 700TB 703 7330 7341 7342 7343 7344-TB 7345 7346 7347 7348-TB 7351 7352 7353 7354 7355 7356 7357 7358 7360 7361 7362 7363 7364 7365 7366 7367 7368 8120 8121 8123 8124 8125 8130 8131 8132 8134 815-TB 816 817 818 819 820 821 822 Page Number 38 38 38 38 45 45 45 45 45 45 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 105 33 33 33 36 36 34 34 34 34 20 20 20 20 20 20 20 20 Catalogue Number Page Number 33 33 33 36 36 22 20 33 33 33 36 36 22 33 33 33 36 36 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 22 33 33 33 36 36 22 22 22 22 33 33 33 36 36 33 8220 8221 8223 8224-TB 8225 823 824 8320 8321 8323 8324-TB 8325 841TB 8420 8421 8423 8424 8425 842ALTB 842TB 843ALTB 843TB 844 844AL 845 845AL 846 846AL 847 847AL 848 848AL 849 849AL 850 850AL 851 851AL 8520 8521 8523 8524 8525-TB 853 853AL 854 854AL 8620 8621 8623 8624 8625 8720 175 Catalogue Number 8721 8723-TB 8724-TB 8725-TB 8820 8821 8823-TB 8824-TB 8825 8850 8851 8853 8854 8855 8970 8971 8973 8974 8975 9306 9330 9331 9340 9341 9342 9343TB 9344 9350 9351 9352TB 9353TB 9354TB 9360 9361 9362 9363 9364 Page Number 33 33 36 36 33 33 33 36 36 33 33 33 36 36 33 33 33 36 36 106 106 106 106 106 106 106 106 106 106 106 106 106 106 106 106 106 106 Notes 176
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Author : picarj Create Date : 2011:11:28 11:07:27-05:00 Modify Date : 2012:12:28 13:39:18-05:00 X Press Private : %%DocumentProcessColors: Cyan Magenta Yellow Black.%%EndComments XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Creator Tool : QuarkXPress(R) 8.5 Metadata Date : 2012:12:28 13:39:18-05:00 Producer : Acrobat Distiller 10.0.0 (Windows) Format : application/pdf Title : 75438_1-ENG Creator : picarj Document ID : uuid:9c56fb2a-8e93-4bcd-9c1a-e9b298138453 Instance ID : uuid:721fbceb-14d1-4c39-b85c-651e8cc7593e Page Count : 176EXIF Metadata provided by EXIF.tools