T&B Conduit Fittings
Table of Contents
Specifications for Rigid Metal Conduit 5-10
Locknuts, Sealing Fittings, 11, 12
Bonding and Grounding Wedges
Bushings 13-19
Knockout Plugs 20–21
Chase ®Nipple 22-2222-23
Threaded Bullet ®Hubs 24-27
T&B Hub 28-31
Threadless Fittings/Couplings 32-34
Set Screw Fittings/Couplings 35, 36
Short Elbows 37
Erickson ®Threaded Couplings 38-40
Conduit Straps and Spacers 41-44
Combination Couplings, 45
Beam Clamps, Conduit Supports
Methods of Bonding and Grounding 46-53
Rigid and Intermediate 5-53
Metal Conduit Fittings
Specifications for EMT 54-56
EMT Fittings 57-59
Electrical Metal Tubing 54-59
(EMT) Fittings
Specifications for Flexible 60-62
Cord and Cable
Selection Guide 63, 64
Specifications for Liquidtight 65
Flexible Cord and Cable Fittings
Strain Relief Fittings 66-69
Ranger Series Liquidtight 70, 71, 73, 75
Strain Relief Fittings
Aluminum Liquidtight Strain 72
Relief Fittings
SS Liquidtight Conduit Connectors 74
Silver Grip—TCFSeries 76, 77
Tray-Cord Fitting
Silver GripLiquidtight Fittings 78, 79
iremesh Grips 80
Nonmetallic Cable Glands 81
Metric Adapters, Fittings and Plug 82
Flexible Cord and Cable Fittings 60-82
General Information 4
1-e.pdf 1 11/28/2011 11:24:25 AM
2
CONFITMRO_EN_ALL.pdf 2 11/28/2011 11:05:17 AM
Armoured Cable and Flexible 111-119
Metal Conduit Fittings
Nonmetallic Sheathed 120-126
Cable Fittings
Liquatite ®Flexible Conduit 127-155
Conduit Dimensional Data 156, 157
Conduit Chemical Resistance Guide 158-161
Alphanumeric Index 162-175
T&B Conduit Fittings
Table of Contents
Specifications 83-85
Service Entrance Cable Fittings 86, 87
Service Entrance Cable Fittings 83-87
Liquidtight Flexible Conduit Fittings 88-110
Specifications for Armoured 111-114
Cable and Flexible Metal Conduit
Fittings for Armoured Cable 115-119
and Flexible Metal Conduit
Specifications for Nonmetallic 120, 121
Sheathed Cable Fittings
Fittings for Nonmetallic Sheathed 122, 126
Cable Fittings
Application Guide 127,128
Steel 129-135, 137, 139
142, 144, 145
Aluminum 136, 138, 143
Shielding 140, 141
Nonmetallic 146, 147
Corrlok®System 148-152
Engineering Information 153, 154
Packaging 155
Specifications for Liquidtight 88-90
Flexible Metal Conduit
High Temperature Flexible 91
Metal Liquidtight Fittings
Liquidtight Flexible Metal 92-100, 103-106, 109
Conduit Fittings
Specifications Type A Nonmetallic 101
Conduit Fittings
Liquidtight Flexible Nonmetallic 101, 102, 107, 108
Conduit Fittings
ISO Metric BulletTM Liquidtight Fittings 110
CONFITMRO_EN_ALL.pdf 3 11/28/2011 11:05:17 AM
General Information
4
T&B Conduit Fittings
Thomas & Betts…
The Complete Product Line
Since the turn of the century, Thomas & Betts
has been a recognized leader in electrical
fittings. Industry standards such as Chase®
Nipples and Erickson®Couplings were
introduced by Thomas & Betts and are
still registered trademarks. This leadership
continues. Here’s why.
Innovative Designs
The real test of product design of
electrical fittings lies in two areas: job-
suited installation and life-of-the-job
reliability. Thomas & Betts Fittings
provide both because we listen. We listen
to problems and suggestions from the
field. Most of the products in this section
result from the good suggestions of
knowledgeable electrical people. Many
were custom designed to solve a
customer’s particular installation and
performance problems. You can
benefit from their experience.
Approvals and Certifications
Electrical raceways require accessory
fittings that provide the mechanical
strength, ground continuity, and
environmental integrity of the system.
As new raceways have been
introduced, Thomas & Betts, engineers
have designed fittings which meet the
requirements of the Canadian Electrical
Code, as well as
the
Canadian
Standards Association. You can use
Thomas & Betts Fittings with confidence.
Note: All dimensions in this catalogue are
approximate.
High Performance Products
Quality and performance result
when engineering design skills are
combined with the manufacturing
technologies
required to produce them.
The Thomas & Betts
Fittings in this
section are produced from many
materials and by many manufacturing
methods, each carefully selected for its
end use suitability. This combination
gives you the reliable performance you
expect from Thomas & Betts
Raceway Fittings.
Lower Installed Cost
Lower installed cost is a function of
purchase cost, availability, installation
advantage, and performance; it
comes in
every carton of Thomas & Betts
Raceway
Fittings.
CONFITMRO_EN_ALL.pdf 4 11/28/2011 11:05:17 AM
Specifications Rigid Metal Conduit/PVC Coated Rigid Metal Conduit
5
T&B Conduit Fittings
Rigid Metal Conduit Fittings
Ref. CEC Rule 12-1000
Rigid Metal Conduit affords maximum
mechanical protection to conductors
within the raceway. Rigid metal conduit
can be installed indoors and outdoors, in
dry locations or wet locations, exposed or
concealed, in all atmospheric conditions
and in hazardous locations.
Galvanized rigid steel conduit
installed in concrete does not require
supplementary corrosion protection.
Galvanized rigid steel conduit, installed in
contact with soil, does not generally
require supplementary corrosion
protection. However, when buried in
corrosive soil (corrosive soil is
characterized by low resistivity of less
than 2,000 ohm-centimeter) or cinders, a
protective coating of bitumastic, asphalt-
based paint or a PVC coating is applied
to the conduit. CEC Rule 12-934
requires that rigid steel conduit installed in
or under permanently moist cinder fill be
encased in at least two inches of
cinder-free concrete unless the conduit is
at least 18 inches below the fill. Steel
conduit protected from corrosion solely by
enamel can only be used indoors and in
occupancies not subjected to severe
corrosive influences.
Rigid nonferrous metal conduit
(aluminum) cannot be directly
embedded in concrete containing
soluble chlorides such as calcium
chloride; unwashed beach sand,
seawater, or coral bearing aggregates.
However, if adequately treated by a
protective coating of bitumastic or
asphalt-based paint or PVC coating, the
conduit can be installed in concrete
containing chlorides.
Supplementary nonmetallic coatings
presently used on ferrous rigid metal or
nonferrous metal have not been
investigated for resistance to corrosion.
CEC Rule 12-920 requires that when
conduit enters a box or fitting, a bushing
must be provided to protect wires from
abrasion unless the design of the box or
fitting provides equivalent protection.
According to CEC Rule 12-906
where No. 8 or larger ungrounded
conductors enter or leave a conduit, an
insulating bushing with a smooth well
rounded insulating surface must be
provided to protect conductors unless
the terminating fitting is equipped with an
insulated throat, firmly secured in place
providing equivalent protection. The
insulating bushing or insulating material
must have a temperature rating of not less
than the insulation temperature rating of
installed conductors. When conduit
bushings are constructed wholly of
insulating material, a locknut must be
installed both inside and outside of the
enclosure to which the conduit is
attached.
Fittings and couplings are required
to be of concrete-tight type when
embedded in masonry or concrete or in
dry locations and of the raintight type
when installed in wet locations.
In wet locations or locations
where walls are frequently washed or
where there are surfaces of absorbent
materials, the entire wiring system
including boxes, fittings, conduit and
cables must be supported such
that there is at least 1/4 inch air space
between it and the supporting surface
(CEC Rule 2-122).
CEC Rule 12-3022 requires that the
raceways be metallically joined together
into a continuous electric conductor
and must be mechanically connected to
all boxes, fittings and cabinets as to
provide effective electrical continuity.
Conduit is required to be supported
adequately and conduit bends in
one run are restricted to the equivalent
of four quarter i.e. 360 degrees total.
Listed below are some of the
advantages of rigid aluminum conduit
over rigid steel conduit.
1. Non-sparking—eliminates hazard in
explosive atmospheres
2. Non-magnetic—reduces power loss
due to voltage drop
3. Resists most corrosive atmospheres
and industrial environments
4. Lightweight—reduces cost
of handling and installation
5. Attractive appearance
CONFITMRO_EN_ALL.pdf 5 11/28/2011 11:05:17 AM
6
T&B Conduit Fittings
Rigid Metal Conduit Fittings
For further details and complete
information please refer to the following:
1. ANSI C80.1…Rigid Steel Conduit
Zinc Coated, Specifications for
2. ANSI C80.2…Rigid Steel Conduit,
Enameled, Specifications for
3. ANSI C80.5…Rigid Aluminum
Conduit. Specifications for
4. ANSI C80.4…Fittings for Rigid Metal
Conduit and Electrical Metallic
Tubing, Specifications for
5. WW-C-581…Federal Specification,
Conduit, Metal, Rigid & Coupling,
Elbow, and Nipple, Electrical
Conduit, Zinc Coated
6. WW-C-540…Federal Specification,
Conduit, Metal, Rigid (Electrical,
Aluminum)
7. WW-C-571…Federal Specification,
Conduit, Metal, Rigid, and Coupling,
Elbow, and Nipple, Electrical
Conduit Enameled
8. U.L. 6…Standards for Safety. Rigid
Metal Conduit
9. U.L. 2142…Standards for Safety.
Intermediate Metal Conduit
10. CEC Section 12-1000…Rigid and
Flexible Conduit
11. CSA C22.2 No. 45…Safety
Standards for Rigid Metal Conduit
12. CSA C22.2 No. 18…Safety
Standards for Outlet Boxes,
Conduit Boxes and Fittings
13. NEMA FB-1…Standards
Publication. Fittings and Supports
for Conduit and Cable Assemblies
14. A-A-50553 Federal Specification.
Fittings for Conduit Metal Rigid
(Thickwall & Thinwall [EMT] Type)
Please Note
The excerpts and other material herein, whether relating to the
Canadian Standards Association, the Underwriters Laboratories, Inc.
listing, to industry practice or otherwise, is not intended to
provide all relevant information required for use and installation.
Reference to original or primary source material and data is
mandatory before any application or use is made of the product.
Specifications Rigid Metal Conduit/PVC Coated Rigid Metal Conduit (continued)
CONFITMRO_EN_ALL.pdf 6 11/28/2011 11:05:17 AM
7
T&B Conduit Fittings
Rigid Metal Conduit Fittings
Rigid ferrous metal conduit or PVC
coated rigid conduit prior to coating
shall be of the hot dipped galvanized
type adequately protected against
corrosion inside and outside including
threads, and conforming to the
following applicable specifications:
-Rigid Ferrous Metal Conduit Federal
Specification WW-C-581/ANSI
C80.1/U.L. 6/CSA C22.2 No. 45
-PVC Coated Ferrous Metal Conduit
Applicable listed under (i) and in
addition conforming to NEMA
Publication No. RNI-2005 (Type A)
PVC coating on conduit and asso-
ciated fittings shall have no sags,
blisters, lumps or other surface
defects and shall be free of holes.
Rigid nonferrous metal conduit shall
conform to Federal Specification
WW-C-540/ANSI C80.5/U.L. 6/CSA
C22.2 No. 45.
All field cuts shall be square, reamed
and deburred. Conduit threads shall
be tapered for entire length with 3¼4
taper per ft. Conduit threads prior to
assembly shall be clean and coated
with grease metallic type conductive
compounds such as series CP8
KOPR-SHIELD for ferrous conduit or
series AP8 ALUMA-SHIELD for
nonferrous
(aluminum) conduit as manufactured
by Thomas & Betts.
To prevent ingress of plaster, dirt,
trash or moisture in raceways, boxes,
fittings and equipment during course
of construction, all open ends shall
be closed with rugged thermoplastic
plugs as manufactured by Thomas &
Betts, series 1470 and 1451. Plugs
shall be firmly secured in place to
provide adequate seal and shall be
functionally unaffected by moisture.
Thermoplastic plugs shall be rated at
105°C/221°F and have a U.L.
flammability rating of 94V-1.
Cat. #CP8
KOPR-SHIELD*
* TM of Jet-Lube, Inc.
Cat. #AP8
ALUMA-SHIELD ®
Series 1451
Knockout Plug
Series 1470
Plug, Conduit/Fitting
Suggested Specifications for Rigid Metal Conduit/PVC Coated Rigid Metal Conduit
and Fittings meets 2009 CEC Rule 2-112
CONFITMRO_EN_ALL.pdf 7 11/28/2011 11:05:18 AM
8
T&B Conduit Fittings
Rigid Metal Conduit Fittings
Suggested Specifications for Rigid Metal Conduit/PVC Coated Rigid Metal Conduit
and Fittings (continued)
Series 1276
Conduit Strap
Series 700
Adjustable Beam
Clamp
Series 1350
Conduit Spacer
Series 5302
Sealing Gasket
Series 370
Threaded Hub
(Raintight)
Series 485 PVC
Coated Threaded
Hubs (Raintight)
Series 8123
Threadless Fitting
(Concretetight)
Series 8120
Threadless Coupling
(Concretetight)
Series 8125
Set Screw Fitting
(Concretetight)
Series 8124
Set Screw Fitting
(Concretetight)
Series 140
Locknut
Series 106
Bonding Locknut
Series 690
Conduit Supports
Conduit shall be securely fastened in
place, at intervals as specified by the
code, using suitable straps, hangers
and other supporting assemblies as
indicated on plans and as
manufactured by Thomas & Betts,
series 1276, 690 and 700. All strap
hangers and supporting assemblies
shall be of rugged construction
capable of supporting weight with a
reasonable factor of safety and shall
be adequately protected against
corrosion. Where applicable, it shall
conform to Canadian Standards
Association Standard C22.2 No. 18.
In wet locations or in locations where
corrosive conditions are present,
vertical and horizontal runs of conduit
shall be firmly supported so that
there is at least 1¼4” air space
between the conduit and the wall
or supporting surface. Spacers and
supporting straps shall be of
malleable iron construction, hot
dipped galvanized conforming to
Canadian Standards Association
Standard C22.2 No. 18 such as
Thomas & Betts series 1276 straps and
series 1350 spacers. Nonferrous metal
straps and spacers may be
substituted as required.
Where threaded conduit terminates
into a threadless opening, a locknut
shall be provided both inside and
outside the box or enclosure and
the conduit end shall be fitted with
an insulating bushing. In wet
locations, a suitable gasket shall
be provided between the outside
locknut and the opening.
Locknuts shall be rugged, of
hardened steel or malleable iron
construction, electro-zinc plated
and capable of cutting through
protective coating on box or
enclosure to ensure positive bond
such as Thomas & Betts series 140.
Where raceway and associated
fittings are used as part of an
equipment grounding system,
terminating fittings shall be equipped
with bonding type locknuts such as
Thomas & Betts series 106 bonding
locknuts.
Sealing gaskets shall be
constructed of oil resistant/moisture
resistant rubber and shall be suitably
protected by and permanently
bonded to a stainless steel retainer
such as Thomas & Betts series 5302.
Where threaded rigid metal conduit is
installed outdoor or indoors or in
locations exposed to continuous or
intermittent moisture, a sealing hub
type terminating fitting shall be installed.
Hubs shall be of malleable iron/steel
construction, electro-zinc plated and
equipped with a nylon insulated throat
and oil resistant/moisture resistant
sealing ring as manufactured by
Thomas & Betts, series 370 or series
H050-TB. Female taper hub threads
shall be adequately relieved to prevent
bottoming of conduit.
Hubs constructed of copper-free
aluminum may be substituted when
used with rigid nonferrous (aluminum)
metal conduit, Thomas & Betts series
370AL or H050A.
For environmental conditions that
are more than normally corrosive
to exposed surfaces, hubs suitably
protected with PVC coating such
as Thomas & Betts series 485 shall
be used.
CONFITMRO_EN_ALL.pdf 8 11/28/2011 11:05:18 AM
9
T&B Conduit Fittings
Rigid Metal Conduit Fittings
Suggested Specifications for Rigid Metal Conduit/PVC Coated Rigid Metal Conduit
and Fittings (continued)
Where concrete-tight requirements
must be met, or in dry locations, rigid
metal conduit or intermediate metal
conduit fittings and couplings shall
be of the concrete-tight type. Fittings
shall be rugged, of ferrous metal
construction, electro-zinc plated
inside and outside, and furnished
with a nylon bushing as
manufactured by Thomas & Betts,
series 8123 and 8120. Insulated set
screw type fittings such as Thomas &
Betts series 8125 and 8124 may be
substituted unless otherwise
indicated on drawings.
Components critical to performance
such as set screws, split rings, and
locknuts shall be hardened or
adequately designed to ensure
positive bond between conduit
and enclosure or conduit runs.
All fittings of the system shall be
capable of carrying ground fault
currents per the following:
1/2” through 1-1/2” size…10,000 amps
RMS (duration of fault current 3 cycles)
2” and above…20,000 amps RMS
(duration of fault current 3 cycles)
All back-to-back nippling of boxes
shall be done using locknuts and nylon
bushed nipples as manufactured by
Thomas & Betts, series 140 locknuts
and series 1942 nipples. Nipples, or
suitably designed bushings such as
Thomas & Betts series 3210, shall also
be used where conductors pass
through either factory or field punched,
cut or drilled holes in metallic
members.
Where neither length of threaded
conduit can be rotated, couplings
such as Thomas & Betts series 674
shall be installed in conduit runs.
Where threaded or threadless
conduit terminates outside a box
or an enclosure, or where conduit is
stubbed up, it shall be equipped with
an insulated metallic or nonmetallic
bushing such as Thomas & Betts series
1222 or TRIB50.
Where code requires bonding and
grounding of single or multiple rigid
metal conduits or where positive
bonding and grounding of conduit to
the box, enclosure or auxiliary gutter
is required, the end of the conduit
shall be equipped with an insulated
metallic grounding and bonding
bushing such as Thomas & Betts
series 3870.
Insulated metallic grounding and
bonding bushing shall be approved for
the purpose. It shall be of malleable
iron/steel construction adequately
protected against corrosion,
assembled
with an insulator listed or certified for
150°C/302°F application and
flammability rating of 94V-0 with
insulator positively secured in place.
Bonding to enclosure shall not be
dependent on locknut bushing type
contact but by a positive bonding
means such as a hardened screw or
equivalent.
Series 140
Locknut
Series 1942
Insulated Nipple
Series 3210
Knockout Bushing
Series 674
Threaded Coupling
Series 222TB
Insulating Bushing
Series TRIB50
Threadless Rigid
Insulating Bushing
Series 3870
Insulated Grounding &
Bonding Bussing
CONFITMRO_EN_ALL.pdf 9 11/28/2011 11:05:18 AM
10
T&B Conduit Fittings
Rigid Metal Conduit Fittings
140 Series
141AL Series
106 Series
Specifications — Locknuts
Application
To connect externally threaded
conduit or fitting to a threadless
opening in a box or enclosure.
To effectively bond conduit or
fitting to box or enclosure.
Features
Hardened Steel/Malleable Iron/
Copper-free Aluminum construction.
Tightens without deformation.
Locknuts specially designed to:
(i) Provide extended reach for
clamping on thin boxes and
enclosures
(ii) Cut through protective coating on
box and enclosure thereby
ensuring ground continuity
(iii) Permit tightening from outside
(iv) Prevent loosening under vibration
106 Series provided with a hardened
cone point screw.
Standard Material
140 Series & 106 Series
3¼8” thru 2” Steel (hardened)
2-1/2” thru 6” Malleable Iron
All screws steel
141AL Series
All copper-free aluminum
(less than .4% copper)
Standard Finish
All Steel and Malleable Iron locknuts
including bonding screws
..........................Electro-zinc Plated
All Aluminum locknuts . . . . . . . .degreased
For chromate coating use prefix 040
Range
3/8” through 6” conduit (all threads
straight pipe [NPS]) (140 Series)
1/2” through 4” conduit (106 Series
& 141AL Series)
Conformance
U.L. 514B
CSA C22.2 No. 18.3
NEMA FB-1
ANSI C80.4
Federal Specification W-F-408
Federal Standard H-28 (Threads)
“Case Hardened Locknuts”
Case hardened locknuts make fittings
faster and easier to install. Case
hardened locknuts do not slip or turn
thereby protecting the biting edge.
Case hardened locknuts bite through
the paint on the enclosure providing
excellent continuity of ground (typical
T&B/ Thomas & Betts fitting with case
hardened locknuts successfully passed
minimum fault current of 10,000 amps
RMS). Case hardened locknuts when
assembled in the intended manner
will not vibrate loose thereby ensuring
excellent ground continuity.
CONFITMRO_EN_ALL.pdf 10 11/28/2011 11:05:18 AM
11
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
Locknuts
Cat. No. Dimensions (in.)
Stl. or M.I. Alum. SST Size A B
139*—— 1/4” 27/32 5/32
140* — 3/8” 15/16 5/32
141** 141AL 141SST 1/2” 1-7/64 5/32
142-TB** 142AL 142SST 3/4” 1-3/8 3/16
143 143AL 143SST 1” 1-11/16 13/64
144 144AL 144SST 1-1/4” 2-5/32 13/64
145 145AL 145SST 1-1/2” 2-1/2 13/64
146-TB 146AL 146SST 2” 3 7/32
147 147AL 147SST 2-1/2” 3-9/16 13/32
148 148AL 148SST 3” 4-3/16 13/32
149 149AL 149SST 3-1/2” 4-13/16 15/32
150 150AL 150SST 4” 5-5/16 15/32
151 151AL 151SST 4-1/2” 5-15/16 17/32
152 152AL 152SST 5” 6 -1/2 17/32
153 153AL 153SST 6” 7-3/4 17/32
* Hex shape
** Case hardened locknuts
Aluminum locknuts comply with federal standard of copper-free aluminum; less than .4% copper.
For Dura-Plate™ finish, add prefix 040- to Cat. No. Consult Customer Service for details.
† Not UL or CSA certified
Bonding Locknuts
Dimensions (in.)
Cat. No. Size Screw Sizes A B
106 1/2” 8-32x 7/16” 1-3/8 .125
107 3/4” 8-32x 7/16” 1-5/8 .140
108 1” 8-32x 7/16” 1-15/16 .170
109 1-1/4” 8-32x 7/16” 2-5/32 .170
110-TB 1-1/2” 8-32x 7/16” 2-1/2 .170
111 2” 8-32x 7/16” 3 .187
112-TB 2-1/2” 1/4-20x 5/8” 3-13/32 .375
113-TB 3” 1/4-20x 5/8” 4-13/16 .375
114 3-1/2” 1/4-20x 5/8” 4-29/32 .438
115-TB 4” 1/4-20x 5/8” 5-7/16 .438
For Dura-Plate™ finish, add prefix 040- to Cat. No. Consult Customer Service for details.
Steel finish: zinc plated
Sealing Fittings
Dimensions (in.)
Cat. No. Size A B C
141SL 1/2 1.140 1/8 1/4
142SL 3/4 1.420 5/32 9/32
143SL 1 1.770 11/64 9/32
144SL 1-1/4 2.281 11/64 5/16
145SL 1-1/2 2.598 11/64 9/32
146SL 2 3.175 3/16 19/64
Steel finish: zinc plated
Steel or malleable iron (steel thru 2”)
or Aluminum 624
Many of the T&B standard conduit and cable
fittings are furnished with “case hardened
locknuts”. This exclusive feature means the
locknut tightens up against the box without
deforming; the locknut bites into the box
providing a positive ground; the fitting can
be tightened from outside the box.
Steel or malleable iron (steel thru 2”).
Use anywhere an ordinary locknut is installed to
ensure positive bonding of conduit to box and
prevent loosening due to vibration. Also can be
used for Service Entrance applications in
conformance with Code. T&B rigid conduit and
E.M.T. (thinwall) fittings comply with Federal
Specification WF 408c.
Molded Santoprene Seal
Color: Blue
Provides positive seal against water and oil. For
use with rigid and intermediate metal conduits,
or fittings to provide watertight or raintight seal
at all enclosures. NPS threads.
(B) Thickness
(B)
Thickness
11-e.pdf 1 2/2/2012 10:36:32 AM
12
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
Sealing Rings with Stainless Steel Retainer
Conduit Dimensions (in.)
Cat. No. Size A B ± 1¼64
5302 1/2” 1-11/64 3/4
5303 3/4” 1-1/2 15/16
5304 1” 1-3/4 1-11/64
5305 1-1/4” 2-9/64 1-1/2
5306 1-1/2” 2-27/64 1-3/4
5307 2” 2-59/64 2-15/64
5308 2-1/2” 3-7/16 2-43/64
5309 3” 4-5/64 3-19/64
5311 4” 5-9/32 4-19/64
NEMA 3R, 4, 6 and 13
Bonding & Grounding Wedges
Bonding and Grounding Wedges
Cat. No. Size
3650 1/2”
3651 3/4”
3652 1”
3653 1-1/4”
3654 1-1/2”
3655 2”
3656 2-1/2”
3657 3”
3658 3-1/2”
3659 4”
3661 5”
3662 6”
Sealing Ring-Santoprene
Thermoplastic Rubber
These sealing rings provide a liquid tight, dust
tight, seal of fitting at enclosures.
Series 3651
Especially suited for grounding old work, but
equally convenient for new, grounding wedges
provide grounding without a jumper except in
concentric knockouts. When a jumper is required, it
fits under a set screw in the grounding wedge.
Update existing installations to meet code
requirements for bonding (CEC Section (10-806)
without disconnecting wiring. Use on new
wiring also.
1. Loosen bushing and position wedge.
2. Tighten bushing and bonding screw.
Series 3650
Application
To effectively bond terminating fitting or
conduit to a box or enclosure.
Features
Sizes 3/4” thru 6” equipped with an
additional bonding screw to install
bonding jumper where required.
Can be added to an existing installation
without disconnecting conductors.
Standard Material/Finish
1/2” size ............Steel/Electro-zinc Plated
3/4” thru 6” size..........Bronze/Tin Plated
Range
1/2
” thru 6” conduit
Conformity
U.L. 467
C.S.A. C22.2 No. 41
NFPA70-2008 (ANSI)
Federal Specification A-A-50552
BA
CONFITMRO_EN_ALL.pdf 12 11/28/2011 11:05:19 AM
13
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
Blackjack® Conduit Grounding Bushings
Innovative design makes installation
quicker, easier.
The Blackjack®Grounding Bushing
never has to be threaded onto a
conduit. It is simply placed in position on
either a threaded or non-threaded rigid or
IMC conduit, with the grounding lug in
perfect position to accept the
grounding
wire. Even in tight installations,
it’s as
simple as one, two, three. Compare
the installation with conventional
bushings that must be threaded onto
the conduit. In tight areas, you may
have to remove the grounding lug,
keep up with the loose parts, and then
reattach the lug. Then you still have to
twist and turn the bushing to get the
lug in position to accept the grounding
wire. The Blackjack bushing does
away with these needless delays for
good, making it the ideal grounding
bushing and the only logical choice for
small spaces, corners, and multiple
conduit runs. And, because the
grounding lug is an integral part of the
bushing, it is designed not to fall off or
get lost.
Innovative design improves
performance.
The Blackjack®bushing provides
superior ground continuity.
The design of the Blackjack bushing
has an integral, cast-on grounding lug
for better ground continuity. This
means that the Blackjack bushing
stands up to intense loads.
Secure grip
forms lasting
bond.
The Blackjack
bushing’s cone-
point mounting
screw bites
securely into both
threaded and
non-threaded rigid conduits. And the
Blackjack bushing’s nylon locking patch
is designed to prevent the screw from
loosening due to vibration.
Reduce inventory.
Because the Blackjack Grounding
Bushing is designed for threaded and
non-threaded conduits, and the ground
lugs are designed to handle an
extended range, the number of parts in
inventory is reduced by up to two-thirds
without losing any application coverage.
Mounting
screw with
nylon locking
patch has a
cone point to
lock bushing
securely in
place.
Insulator surface
features a rounded
design to reduce
drag and prevent
abrasion during
wire pulling.
Cast “threads”
opposite the
mounting screw
tighten the fit
during installation.
Angle of lug
screw improves
accessibility
when securing
grounding wire.
Integral grounding
lug enhances
ground continuity.
Added ground
wire range taking
reduces inventory.
Accepts copper or
aluminum ground
wires.
Insulating nylon
surface is 150°C
rated and covers
top of bushing,
including lug
corners.
Blackjack®– Conduit Grounding Bushing
Lug Screw:
14-4: Slotted
14-2/0: Slotted
6-4/0: Internal Hex Drive
Standard Material/Finish
Body: Malleable Iron or Aluminum
Mounting Screw: (1/2"-2") Stainless
Steel, (2-1/2"-6") Brass
Lug Screw: Stainless Steel
Finish: Zinc Plated or Mechanical
Galvanized
Range
Conduit: 1/2 thru 6" threaded or
threadless rigid/IMC
Wire Range: #14 AWG to 4/0 AWG
CU/AL
Conformity
U.L. 514B & U.L. 467
CSA C22.2 No. 18.3 & CSA C22.2
No. 41
CONFITMRO_EN_ALL.pdf 13 11/28/2011 11:05:19 AM
14
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
Cat No.
Zinc Conduit Dim.
Plated Size ØA ØB ØC ØD E Wire
Malleable Iron Aluminum in. Max. Max. Max. Max. Max. Range
BG050-14-20 BGA050-14-20 1/2 1.251 .569 1.181 2.134 .696 14-2/0
BG050-14-4 BGA050-14-4 1/2 1.251 .569 1.027 1.940 .696 14-4
BG075-14-20 BGA075-14-20 3/4 1.533 .772 1.221 2.414 .696 14-2/0
BG075-14-4 BGA075-14-4 3/4 1.533 .772 1.030 2.168 .696 14-4
BG100-14-20 BGA100-14-20 1 1.783 .993 1.181 2.581 .696 14-2/0
BG100-14-4 BGA100-14-4 1 1.783 .993 1.027 2.368 .696 14-4
BG125-14-20 BGA125-14-20 1-1/4 2.220 1.319 1.181 2.987 .759 14-2/0
BG150-14-20 BGA150-14-20 1-1/2 2.470 1.553 1.181 3.236 .696 14-2/0
BG200-14-20 BGA200-14-20 2 2.830 2.010 1.181 3.766 .696 14-2/0
BG250-14-20 BGA250-14-20 2-1/2 3.148 2.412 1.181 4.341 .978 14-2/0
BG250-6-40 BGA250-6-40 2-1/2 3.148 2.412 1.524 4.526 .978 6-4/0
BG300-14-20 BGA300-14-20 3 4.042 3.022 1.181 4.966 .978 14-2/0
BG300-6-40 BGA300-6-40 3 4.042 3.022 1.524 5.139 .978 6-4/0
BG350-14-20 BGA350-14-20 3-1/2 4.542 3.491 1.181 5.467 .978 14-2/0
BG350-6-40 BGA350-6-40 3-1/2 4.542 3.491 1.524 5.639 .978 6-4/0
BG400-14-20 BGA400-14-20 4 5.042 3.975 1.181 5.966 .978 14-2/0
BG400-6-40 BGA400-6-40 4 5.042 3.975 1.524 6.139 .978 6-4/0
BG500-14-20 BGA500-14-20 5 6.136 4.991 1.181 7.045 .978 14-2/0
BG500-6-40 BGA500-6-40 5 6.136 4.991 1.524 7.207 .978 6-4/0
BG600-14-20 BGA600-14-20 6 7.199 6.009 1.181 8.087 .978 14-2/0
BG600-6-40 BGAT600-6-40 6 7.199 6.009 1.524 8.409 .978 6-4/0
Suggested Specifications
Insulated grounding and bonding bushing
(Series BG050-BG600)
Where code requires bonding and grounding of single or multiple metal conduits, or positive bonding and grounding of metal conduit to the
box, enclosure or auxiliary gutter, the end of the conduit shall be equipped with an insulated metallic grounding and bonding bushing series
BG050-14-20 as manufactured by Thomas & Betts.
Grounding and bonding bushings used shall be approved for the purpose and
(i) Shall be of malleable iron/steel/aluminum construction adequately protected against corrosion.
(ii) Bushing insulator shall be listed or certified for 150°C/302°F application with a flammability rating of 94V-O. Insulator must be positively
locked in place.
* Mechanical galvanization is available in the 3870 Series; add suffix MG to Cat. No.
Blackjack® Conduit Grounding Bushings
Cat No.
D
C
Lug Screw
14-4: Slotted
14-2/0: Slotted
6-4/0: Internal hex drive
For Threaded & Threadless Rigid & IMC Conduit.
Nylon Insulator (150oC) Mounting Screw
E
ØA
ØB
Throat I.D.
t
t
t
t
t
t
t
t
t
t
CONFITMRO_EN_ALL.pdf 14 11/28/2011 11:05:19 AM
15
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
Threaded Insulated Grounding Bushing
Threaded Insulated Grounding Bushing
Wire
Range
Conduit Bushing Throat Lug Swing Bushing AWG
Cat. No. Size Dia. Dia. Length Radius Height CU/AL
3870-TB 1/2 1.125 .560 1.310 1.212 .657 14-4
3861 1/2 1.125 .560 1.675 1.402 .657 8-2/0
3871-TB 3/4 1.420 .742 1.310 1.360 .660 14-4
3862 3/4 1.420 .742 1.675 1.550 .660 8-2/0
3872 1 1.770 .944 1.310 1.535 .735 14-4
3882 1 1.770 .944 1.675 1.725 .735 8-2/0
3873 1-1/4 2.190 1.242 1.310 1.745 .735 14-4
3883 1-1/4 2.190 1.242 1.675 1.935 .735 8-2/0
3874 1-1/2 2.468 1.449 1.310 1.884 .770 14-4
3884 1-1/2 2.468 1.449 1.675 2.074 .770 8-2/0
3875 2 3.031 1.860 1.310 2.165 .770 14-4
3889 2 3.031 1.860 1.675 2.355 .770 8-2/0
3876 2-1/2 3.516 2.222 1.310 2.408 .940 14-4
3886 2-1/2 3.516 2.222 1.675 2.598 .940 8-2/0
3993 2-1/2 3.516 2.222 2.230 2.928 .940 6-4/0
3877 3 4.234 2.761 1.310 2.767 .975 14-4
3887 3 4.234 2.761 1.675 2.957 .975 8-2/0
3994 3 4.234 2.761 2.230 3.287 .975 6-4/0
3878 3-1/2 4.781 3.193 1.310 3.040 .975 14-4
3863 3-1/2 4.781 3.193 1.675 3.230 .975 8-2/0
3995 3-1/2 4.781 3.193 2.230 3.560 .975 6-4/0
3879 4 5.328 3.623 1.310 3.314 .980 14-4
3864 4 5.328 3.623 1.675 3.504 .980 8-2/0
3996 4 5.328 3.623 2.230 3.834 .980 6-4/0
3880 5 6.328 4.542 1.310 3.814 .985 14-4
3865 5 6.328 4.542 1.675 4.000 .985 8-2/0
3998 5 6.328 4.542 2.230 4.334 .985 6-4/0
3881 6 7.406 5.458 1.310 4.353 1.200 14-4
3866 6 7.406 5.458 1.675 4.543 1.200 8-2/0
3999 6 7.406 5.458 2.230 4.875 1.200 6-4/0
Temperature rating 150°C.
Meets Coast Guard Regulation CG293
For Dura-Plate™ finish, add prefix 040- to Cat. No. Consult Customer Service for details.
*Contact customer service for copper lay in lug
Application
For quick installation of bonding
jumper to multiple metal conduits
(Rigid and IMC).
Designed to bush conductors and
prevent insulation damage.
Features
Ease of installation, lay in lug design.
Cast malleable iron body designed to
lock insulator in place within body
reducing common assembly problem
resulting in dislodging of insulator.
Insulator rated for 150°C/302°F
application.
Standard Material / Finish
Body: Electro-zinc plated
Lay-in lug: Aluminum/tin plated
Insulator: Thermoplastic
150°C/302°F
Application with 94V-0 flammability.
Wire
Clamping Screw
Insulator
Set-Screw
(one)
Lay-In*
Lug
Bushing
Casting
CONFITMRO_EN_ALL.pdf 15 11/28/2011 11:05:20 AM
16
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
Insulated Throat Fittings
Dimensions (in.)
Cat. No. Size A B
1222 1/2” 1-1/32 29/64
1223 3/4” 1-9/32 31/64
1224 1” 1-19/32 19/32
1225 1-1/4” 1-15/16 21/32
1226 1-1/2” 2-3/16 23/32
1227 2” 2-11/16 7/8
1228 2-1/2” 3-3/16 31/32
1229 3” 3-27/32 15/16
1230 3-1/2” 4-7/16 1-1/16
1231 4” 4-7/8 1-3/32
12324-1/2” 5-7/16 1-15/64
586 5” 5-31/32 1-9/32
587 6” 7-3/16 1-11/32
Not CSA Certified
Catalogue series 1222 thru 1232, 586 and 587 are available in aluminum. Add suffix AL to
Cat. No. The aluminum series are not CSA certified.
Metallic Bushings
Cat. No. Dimension (in.)
Stl. or M.I. Alum. Size A B
122 122AL 1/2” 1-1/32 13/32
123 123AL* 3/4” 1-9/32 13/32
124 124AL 1” 1-19/32 1/2
125-TB 125AL 1-1/4” 1-15/16 9/16
126 126AL 1-1/2” 2-3/16 9/16
127 127AL 2” 2-11/16 19/32
128 128AL 2-1/2” 3-3/16 13/16
129 129AL 3” 3-27/32 13/16
130-TB 130AL 3-1/2” 4-7/16 15/16
131-TB 131AL 4” 4-7/8 1
132-TB 4-1/2” 5-7/16 1-5/64
133-TB 133AL 5” 6-1/16 1-1/16
134-TB 134AL 6” 7-3/16 1-1/16
* Not U.L. Listed or CSA Certified
For Dura-Plate™ finish, add prefix 040- to Cat. No. Consult Customer Service for details.
Nylon insulated
metallic bushings
Steel or malleable iron (Steel thru 1-1/2 ”).
The Canadian Electric Code 10-906 (2) calls for
protection of ungrounded conductors by means
of smoothly rounded insulating surfaces at the
entrance to raceways, pull boxes, junction boxes,
etc. T&B insulated throat fittings, recognizable
by the distinctive trademarked blue insulating
liner in the throat, meet and surpass this Code
requirement. In addition, T&B insulated fittings
also reduce wire pulling effort by as much as
50%. Temperature rating 105°C.
Aluminum, steel or malleable iron
(steel thru 1-1/2”).
Smoothly rounded shoulder covers end of
conduit; broad flange covers knockout hole.
High ribs make tightening easy with fingers or
with wrench. 1/2”-1-1/2” sizes, formed in steel,
have extra smooth shoulders. Locknut-type
base gives improved bonding and resists
loosening under conditions of vibration.
CONFITMRO_EN_ALL.pdf 16 11/28/2011 11:05:20 AM
17
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
Plastic Insulating Bushings
Dimensions (in.)
Cat. No. Size A B
222-TB 1/2” 1-1/16 3/8
223-TB 3/4” 1-9/32 13/32
224 1” 1-37/64 9/16
225-TB 1-1/4” 2-1/32 9/16
226 1-1/2” 2-15/64 9/16
227 2” 2-25/32 5/8
228-TB 2-1/2” 3-13/32 3/4
229-TB 3” 4-3/32 3/4
230-TB 3-1/2” 4-5/8 7/8
231 4” 5-3/16 7/8
232 4-1/2” 5-5/8 7/8
233 5” 6-3/8 1
234 6” 7-7/16 1
Flame retardant. U.L. Rated 94V-1.
All Plastic Insulating Bushings
Impact-resistant plastic insulation. These
bushings have ribs for gripping when installing.
Perfect threads for easy thread on. U.L. Listed
105°C. NPT threaded.
A
B
CONFITMRO_EN_ALL.pdf 17 11/28/2011 11:05:20 AM
18
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
Insulating Bushing
(For Threadless Rigid Conduit and Intermediate Metal Conduit)
Insulated Metallic Bushing
Dimensions (in.)
Cat. No. Size A B C
TRIB-50 1/2” 19/32 1-9/32 1-1/16
TRIB-75 3/4” 25/32 1-25/64 1-1/4
TRIB-100 1” 1 1-1/2 1-9/16
TRIB-125 1-1/4” 1-5/16 1-5/8 1-59/64
TRIB-150 1-1/2” 1-17/32 1-21/32 2-11/64
TRIB-200 2” 1-31/32 1-13/16 2-11/16
TRIB-250 2-1/2” 2-23/64 2 3-1/4
TRIB-300 3” 2-59/64 2-7/32 3-29/32
TRIB-350 3-1/2” 3-3/8 2-5/16 4-29/64
TRIB-400 4” 3-27/32 2-13/32 5
I.M.C. sizes 1/2” thru 4”
U.L. Rated flame retardant 94V-1.
Application
When assembled to the end of a
threadless conduit, provides a well
rounded insulating surface over
which conductors may be pulled
or on which conductors may bear
while in service.
Features
Designed to be popped onto, and
bush, conduit end.
Fast easy installation without screws.
High impact thermoplastic
construction.
Standard Material
High impact thermoplastic listed for
105°C (221°F) application.
Flammability Classification 94V-1.
Standard Finish
As molded.
Range
1/2” through 4” conduit
Conformity
U.L. 514B
ANSI C80.4
NFPA 70-2008 (ANSI)
1. Cut conduit end squarely. Remove sharp edges
and burrs on inside and outside diameters by
reaming or filing.
2. Slip the pop-on bushing over the end of the
conduit.
3. Using the flat surface of any standard utility tool
such as an electricians pliers (or a hammer with
a block of wood, for the larger sizes), strike the
bushing on its top surface using a series of light
blows until the end of the conduit rests against
the bushing throat and conduit stop.
C
B
A
TRIB50 Series
CONFITMRO_EN_ALL.pdf 18 11/28/2011 11:05:20 AM
19
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
Knockout Bushings
Knockout Bushing
For use Wall
Trade in KO* Thickness
Cat. No. Size +.032/ -.016 A B of Elec. Box C D
3210 1/2” .875 1.000 .725 .095 MAX .360 .180
3211 3/4” 1.109 1.215 .940 .095 MAX .360 .180
3212 1” 1.375 1.500 1.200 .095 MAX .360 .180
3213 1-1/4” 1.734 1.865 1.550 .140 MAx .400 .210
3214 1-1/2” 1.984 2.240 1.760 .140 MAX .530 .310
3215 2” 2.469 2.740 2.245 .140 MAx .530 .310
* Per U.L. and NEMA standards.
Material: Thermoplastic
Flammability classification of 94V-1 Per UL 94
Service temperature: -40°C to 105°C.
3210 Series
Application
To bush knockout openings in metal
boxes or enclosures.
Features
One piece construction designed to
snap in place.
High impact strength self-extinguishing,
non-dripping (per U.L. 94)
thermoplastic construction.
Standard Material
Thermoplastic rated for 105°C (221°F)
application.
Standard Finish
As molded.
Range
.875” through 2.469” nominal diameter
knockout opening (1/2” through 2”
trade size knockouts).
Wall thickness of box or enclosure
.095” max. up to 1” trade size.
.140” max. 1-1/4” through 2” trade size.
Conformity
U.L. 514B
CSA C22.2 No. 18.3
NFPA 70-2008 (ANSI)
One-piece knockout bushing quickly snaps into
outlet box, switch box, or other enclosure left
vacant by wiring modifications or maintenance
changes. Provides smooth, rounded insulation
surface for easy wire pulling. Easily installed by
hand, they are available to fit 1/2” through 2”
knockouts. U.L. Listed 105°C. High impact
thermoplastic.
INSULINER®Sleeves
Dimension (in.)
Cat. No. Size A B
422 1/2” 5/8 .022
423 3/4” 11/16 .025
424 1” 7/8 .040
425 1-1/4” 1 .040
426-TB 1-1/2” 1 .050
427-TB 2” 1-1/8 .050
428-TB 2-1/2” 1-1/4 .035
429 3” 1-1/2 .035
430-TB 3-1/2” 1-25/32 .035
431 4” 2-1/32 .035
433 5” 2-1/2 .035
434 6” 2-1/2 .035
Oxygen index >28°
A
B
Slip over wires—insert
into bushing—snaps
into place
High dielectric nylon, 105°C.
An insuliner sleeve snapped into a regular
bushing makes a CSA Listed insulated bushing. For
standard rigid conduit, E.M.T. (thinwall conduit)
or any standard bushed outlet. Especially
suitable for use with flexible metallic conduit.
Converts ordinary bushing to code approved
insulated bushing without disturbing wiring.
19-e.pdf 1 2/21/2012 4:02:52 PM
20
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
Knockout Plugs
Knockout Plugs
Dimensions (in.)
Cat. No. Size A B
1451 1/2” 1.060 .400
1452 3/4” 1.300 .400
1453 1” 1.590 .400
1454 1-1/4” 1.860 .450
1455 1-1/2” 2.240 .570
1456 2” 2.740 .570
Wall thickness of electrical box .095 max.
Meets Coast Guard Regulation CB293.
105°C rated by U.L. Made from flame
retardant, non-dripping thermoplastic.
A penny under a bushing will seal
the end of the conduit during
construction. Made to fit any
bushing. Completely salvageable.
Pennies—Steel
Cat. No. Size
815-TB 1/2”
816 3/4”
817 1”
818 1-1/4”
819 1-1/2”
820 2”
821 2-1/2”
822 3”
824 3-1/2”
823 4”
U.L. not applicable
Application
To bush knockout openings in metal boxes or enclosures.
Features
One piece construction designed to snap in place.
High impact strength self extinguishing nondripping (per
U.L. 94) thermoplastic construction.
Standard Material
Thermoplastic rated for 105°C
(221°F) application.
Standard Finish
As molded.
Range
.875” through 2.469” nominal diameter knockout opening
(1¼2” through 2” trade size knockouts).
Wall thickness of box or enclosure
.095” max. up to 1” trade size.
.140” max. 1-1/4” through 2” trade size.
Conformity
U.L. 514B
CSA C22.2 No. 18.3
NFPA 70-2008 (ANSI)
A
B
CONFITMRO_EN_ALL.pdf 20 11/28/2011 11:05:21 AM
21
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
Bushings and Push-Penny ®Plugs
Assembly consist of
Cat. No. Size A Bushing Push-penny
1460 1/2” 1-1/32” 122 1470-TB
1461 3/4” 1-9/32” 123 1471
1462 1” 1-19/32” 124 1472
1463 1-1/4” 1-15/16” 125 1473
1464 1-1/2” 2-3/16” 126 1474
1465* 2” 2-21/32” 127 1475
* Maleable Iron
Available in Aluminum
Add suffix AL to Cat. No.
A
Push-Penny ®Plugs
Cat. No. Size
1470-TB 1/2”
1471 3/4”
1472 1”
1473 1-1/4”
1474 1-1/2”
1475 2”
1476* 2-1/2”
1477* 3”
1478* 3-1/2”
1479* 4”
*Not CSA Certified.
CSA File No. 2884
UL not applicable.
Plug, Conduit, Connectors (Push-Penny®Plugs)
Application
To plug open end of conduit or fitting in order to prevent
ingress of trash, dirt or moisture during construction and
remodeling.
Features
Wide range of application; can be used with rigid metal
conduit, intermediate metal conduit, electrical metallic
tubing, all connnectors and all bushings.
Designed to stand up to normal handling and is functionally
unaffected by moisture.
Standard Material
Polyethylene
Standard Finish
As molded.
Conformity
CSA C22.2 No. 18
ANSI C80.4
NFPA 70-2008 (ANSI)
NEMA FB-1
CEC Rule: 12-3024
“Unused openings in boxes, cabinets and fittings shall be
effectively closed by plugs or plates affording protection
substantially equivalent to that of the wall of the box, cabinet
or fittings.”
CONFITMRO_EN_ALL.pdf 21 11/28/2011 11:05:21 AM
22
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
1942 Series
842AL Series (Non Insulated)
Application
To effectively bush factory or
field-punched, cut, or drilled holes in
metal boxes or enclosures.
To couple boxes back-to-back.
Features
Rugged construction.
Insulator curled over to: Bush
conductors entering/leaving at any
angle. Reduce wire pull effort.
Protect threads against damage
in handling.
Standard Material
1942 Series
Body
1/2”-Steel
3/8”, 3/4” through 6”-Malleable Iron
Insulator Nylon
842AL Series
All Copper-free Aluminum
(less than .4% copper)
Standard Finish
1942 Series Electro-zinc Plated
& Chromate Coated
842AL Series Degreased
Range 1942 & 842AL Series
1¼2” through 6”
All hub threads straight pipe (NPS).
Conformity
U.L. 514B
CSA C22.2 No. 18.3
Federal Specification W-F-408
ANSI C80.4
NFPA 70-2008 (ANSI)
NEMA FB-1
Federal Standard H-28 (Threads)
CHASE ®Nipple
NPS
Threads
Steel, malleable iron or aluminum.
CHASE ®Nipples
Cat. No. Dimensions (in.)
Stl. or M.I. Alum. Size A B
841TB 3/8” 13/16 7/16
842TB 842ALTB1/2” 15/16 11/32
843TB 843ALTB 3/4” 1-3/16 11/32
844 844AL1” 1-7/16 21/32
845 845AL1-1/4” 1-3/4 3/4
846 846AL 1-1/2” 2-1/16 13/16
847 847AL 2” 2-1/2 31/32
848 848AL 2-1/2” 3-1/16 1-1/16
849 849AL 3” 3-13/16 1-3/16
850 850AL 3-1/2” 4-3/8 1-5/16
851 851AL 4” 4-3/4 1-5/16
853 853AL 5” 5-7/8 1-5/16
854 854AL 6” 6-15/16 1-3/8
Not U.L. Listed
For Dura-Plate™ finish, add prefix 040- to Cat. No. Consult Customer Service for details.
CONFITMRO_EN_ALL.pdf 22 11/28/2011 11:05:21 AM
23
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
CHASE®Nipples—Nylon Insulated
Size Dimensions (in.)
Cat. No. in. A B C
1942 1/2 15/16 1/2 19/32
1943 3/4 1-3/16 17/32 23/32
1944 1 1-7/16 21/32 7/8
1945 1-1/4 1-3/4 25/32 1-1/32
1946 1-1/2 2-1/16 13/16 1-3/32
1947 2 2-9/16 31/32 1-11/32
1948 2-1/2 3-1/16 1-1/16 1-7/16
1949 3 3-13/16 1-3/16 1-19/32
1950 3-1/2 4-3/8 1-5/16 1-25/32
1951 4 4-5/8 1-5/16 1-13/16
1953 5 5-29/32 1-5/16 1-13/16
1954 6 6-13/16 1-3/8 1-7/8
Steel or malleable iron
CONFITMRO_EN_ALL.pdf 23 11/28/2011 11:05:21 AM
24
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
485 Series
370 Series
370AL Series
Application
To connect threaded metal conduit
(ferrous rigid/nonferrous rigid/PVC
coated/or intermediate metal) to
a threadless opening in a box or
enclosure in outdoor or indoor
location exposed to continuous
or intermittent moisture.
To positively bond conduit to box
or enclosure.
Features
Rugged steel/malleable iron/copper-
free aluminum construction.
Tapered internal threads for
watertight/dust tight union (A).
Threads relieved to prevent
bottoming of conduit ensuring sound
assembly (B).
Recessed sealing ring at box end.
Captive sealing ring (C).
Hardened steel/malleable iron/
copper-free aluminum locknuts
designed to provide high quality
ground continuity; extended reach of
locknut permits clamping on thin
boxes and enclosures (D).
Insulated throat protects conductors,
prevents abrasion and thinning of
conductor insulation, reduces wire
pull effort (E).
Suitable for hazardous location use
per following:
(i) Class II, Division 1 Groups E, F, G,
CEC Rule 18-202
Class II, Division 2 Groups E, F, G,
CEC Rule 18-252
Class III, Division 1 Rule 18-302
Class III, Division 2 Rule 18-352
PVC coated 485 Series
(i) Protects fitting from extremely
corrosive surroundings without
affecting integrity of electrical
grounding path (F).
(ii) Provided with overlapping sleeve
for additional seal (G).
Canadian Electric Code Rule 10-602
states that, “Where dissimilar metals
cannot be avoided at bonding
connections as indicated in Rule 2-112
(2). Connections shall be made using
methods or material that will minimize
deterioration from galvanic action”.
Joint Industrial Council (JIC) Electrical
Standards also forbid dissimilar metals
in contact for the same reason and
require that the fittings for metal conduit
be of malleable iron or ductile iron and
have impact strength comparable to
that of the conduit.
“Copper-free Aluminum”
Copper-free aluminum castings
for fittings have a maximum of 0.4%
copper. The most detrimental effect of
higher percentage of copper on
aluminum base alloy is its decrease in
corrosion resistance.
Threaded Hubs (Bullet®Hubs)
(For Threaded Rigid Metal Conduit/IMC/PVC Coated Rigid Metal Conduit)
(B)
(C)
(E)
(A)
Predetermined
Compression
(B)
(C)
(E)
(D)
(G)
(F)
(A)
(G)
(D)
CONFITMRO_EN_ALL.pdf 24 11/28/2011 11:05:21 AM
25
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
Threaded Hubs (Bullet®Hubs)—continued
(For Threaded Rigid Metal Conduit/IMC/PVC Coated Rigid Metal Conduit)
Standard Material
370-485 Series 370AL
Body 1/2” thru 1” Steel All Copper-Free Aluminum
1-1/4” thru 6” Malleable Iron
Locknut 1/2” thru 2” Steel (hardened) 1/2” thru 2” Steel (hardened)
2-1/2” thru 6” Malleable Iron 2-1/2” thru 4” Copper-free
Aluminum
Screws Steel (hardened)
‘O’ Ring Buna N
Insulator Nylon
Coating PVC
Standard Finish
370 Series 370AL Series 485 Series
Hub Electro-zinc Plated As Cast PVC—Outside.
Chromate Coated. Electro-zinc
Locknuts All Ferrous locknuts Plated Chromate
Electro-Zinc Plated Coated Inside.
and Chromate Coated.
Screws All Electro-Zinc Plated
& Chromate Coated.
Range
370 Series 1/2” thru 6” Conduit
370AL & 485 Series 1/2” thru 4” Conduit
All hub threads—straight pipe
All female threads—taper pipe
(NPT)
Conformity
U.L. 514B
CSA 22.2 No. 18.3
ANSI C80.4
NFPA 70-2008 (ANSI)
NEMA FB-1
JIC EGP1; JIC EMP 1
Federal Specification W-F-408
Federal Standard H-28 (Threads)
CONFITMRO_EN_ALL.pdf 25 11/28/2011 11:05:21 AM
26
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
Steel/Malleable Iron and Aluminum Hub Fittings
Cat. No. Size Dimensions (in.) Wall Thk.
Stl. or M.I. Alum.** A B C (max.)in.
370 370AL 1/2 1-3/8 1-5/16 3/4 5/16
371 371AL 3/4 1-5/8 1-3/8 7/8 5/16
372 372AL 1 2-3/32 1-23/32 1-7/32 5/16
373 373AL 1-1/4 2-9/16 2 1-11/32 5/16
374 374AL 1-1/2 3-3/32 2 1-11/32 5/16
375 375AL 2 3-5/8 1-31/32 1-11/32 5/16
376 2-1/2 4-1/8 2-21/32 1-15/16 5/16
377 3 5 2-31/32 2 1/2
378 3-1/2 5-9/16 3-1/8 2-1/8 1/2
379-TB 4 6-9/16 3-1/8 2-1/8 1/2
381-TB 5 8 4 2-3/16 1/2
382-TB 6 9-3/16 4 2-3/16 1/2
** Aluminum not available with insulated throat.
U.L. Listed raintight and CSA Certified watertight and dust tight.
For Dura-Plate™ finish, add prefix 040- to Cat. No. Consult Customer Service for details.
Bullet®Hub Fittings with Bonding Locknut —
Nylon Insulated
Cat. No. Size (in.) Description
401 1/2
402 3/4
403-TB 1 Available in steel or malleable iron
404-TB 1-1/4 (steel through 1 inch.).
405-TB 1-1/2 Used with a neoprene “O” ring to provide
407 2-1/2 Supplied with 106 series bonding nut.
408 3Tem perature rating: 105° C.
409 3-1/2
410-TB 4
CSA certified watertight and dust tight.
Nylon insulated.
Aluminum, steel, or malleable iron (steel
through 1”). With Neoprene “O” Ring provides a
watertight threaded hub on enclosures. U.L.
Listed 105°C.
CONFITMRO_EN_ALL.pdf 26 11/28/2011 11:05:22 AM
27
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
PVC Coated Hub for Rigid Conduit
Dimensions (in.)
Cat. No. Conduit Size A B C
485 1/2” 1-21/64 2-1/8 1-7/8
486 3/4” 1-19/32 2-3/8 2-1/8
487 1” 1-27/32 2-3/4 2-3/8
488 1-1/4” 2-15/32 3-3/8 3-1/8
489 1-1/2” 2-29/32 3-5/8 3-1/2
490 2” 3-3/8 3-3/4 4
491 2-1/2” 3-27/32 4 4-1/2
492 3” 4-21/32 4-5/8 5-3/8
493 3-1/2” 5-9/64 4-13/16 5-7/8
494 4” 5-3/4 4-9/16 6-7/16
*485 Series are CSA Certified Watertight and Dustight for Ordinary Locations.
Spacing Chart for Bullet ®Hubs
Center to Center Spacing Min. Space from
Conduit Sizes Center of KO
Bullet®Hub to Diameters
1/2 3/4 1 1-1/4 1-1/2 2 2-1/2 3 3-1/2 4 Wall of Box (min.)
1/2 1-7/16 1-5/8 1-3/4 2-1/8 2-3/8 2-5/8 2-7/8 3-5/16 3-1/2 3-7/8 3/4 7/8
3/4 1-3/4 1-7/8 2-1/4 2-1/2 2-3/4 3 3-1/2 3-3/4 4-1/8 7/8 1-1/8
1 2 2-3/8 2-5/8 2-7/8 3-1/8 3-5/8 3-7/8 4-1/4 1-1/8 1-3/8
1-1/4 2-11/16 2-15/16 3-1/4 3-1/2 4 4-1/4 4-1/2 1-3/8 1-3/4
1-1/2 3-1/8 3-1/2 3-3/4 4-1/8 4-3/8 4-3/4 1-5/8 2
2 3-3/4 4 4-1/2 4-3/4 5 1-7/8 2-1/2
2-1/2 4-1/4 4-3/4 5 5-3/8 2-1/8 3
3 — — — — 5-1/8 5-3/8 5-3/4 2-5/8 3-5/8
3-1/2 — — — — 5-5/8 6 2-7/8 4-1/8
4 — — — — 6-1/4 3-1/4 4-5/8
Steel or malleable iron (steel thru 1-1/4”).
A
B
C
T&B Hub Centerline Spacing Chart
Conduit
Trade Size 1/2 3/4” 1” 1-1/4” 1-1/2” 2” 2-1/2” 3” 3-1/2” 4” 5” 6”
inc.
1/21-9/16
3/41-43/64 1-25/32
11-27/32 1-61/64 2-1/8
1-1/42-1/32 2-9/64 2-5/16 2-1/2
1-1/22-7/32 2-21/64 2-1/2 2-11/16 2-7/8
22-15/32 2-37/64 2-3/4 2-15/16 3-1/8 3-3/8
2-1/22-23/32 2-53/64 3 3-3/16 3-3/8 3-5/8 3-7/8
33-1/32 3-9/64 3-5/16 3-1/2 3-11/16 3-15/16 4-3/16 4-1/2
3-1/23-11/32 3-21/64 3-5/8 3-13/16 4 4-1/4 4-1/2 4-13/16 5-1/8
43-19/32 3} 3-7/8 4-1/16 4-1/4 4-1/2 4-3/4 5-1/16 5-3/8 5-5/8
54-9/32 3-25/64 4-9/16 4-3/4 4-15/16 5-3/16 5-7/16 5-3/4 6-1/16 6-5/16 7
64-11/16 4-51/64 4-31/32 5-5/32 5-11/32 5-19/32 5-27/32 6-5/32 6-15/32 6-23/32 7-13/32 7-13/16
Nearest obstruction to center of hub.
27/32 61/64 1-1/8 1-5/16 1-1/2 1-3/4 2 2-5/16 2-5/8 2-7/8 2-9/16 3-31/32
PLASTIC
COATING
LOCKNUT
NFS THREAD
INSULATOR
SEALING RING
CONFITMRO_EN_ALL.pdf 27 11/28/2011 11:05:22 AM
28
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
THE T&B Hub
Never before has a single hub fit like this one. Designed for unequalled performance. The innovative engineering of the
T&B Hub will, quite simply, raise your performance expectations for threaded hubs. The revolution in hub design is here,
and the fate of our competition is sealed.
Figure 1 Figure 2 Figure 3
1. Sealing ring and groove with
innovative profile outperforms
standard 'O' ring design. Sealing
ring is captive before installation
and resists buckling or slipping during
installation. The seal groove is
designed for op ti mum compression of
the sealing ring. The sealing ring is
designed to provide a complete 360°
seal, even when the conduit is not
perpendicular with the enclosure. (See
Figure 1)
2. Locknut design with pe riph er al
slots and a hexagonal/angled
spline spaced every 30° enables
easy application of torque with
wrench or hammer and screw driv er.
(See Figures 2 & 3)
3. Sharper and deeper teeth on
locknut and body designed for a
more penetrating bite for improved
bonding to the enclosure.
4. Hexagonal / splined body design
for fast, easy installation with
wrench or hammer and screwdriver.
5. Precision machined tapered
threads designed to create water-
tight union.
6. Insulated throat molded from
105°C rated thermoplastic with a
flammability rating of 94 V-O.
B
D
C
A
T&B Hub
Trade Max. Panel Throat
Cat. Size Dia. Thickness Dia.
No. (in.) A B C D E
H050-TB 1/2 1-7/16 1-9/16 7/8 3/16 19/32
H075-TB 3/4 1-21/32 1-19/32 29/32 3/16 25/32
H100-TB 1 2 1-13/16 1-1/16 1/4 1
H125-TB 1-1/4 2-3/8 1-7/8 1-1/16 1/4 1-5/16
H150-TB 1-1/2 2-3/4 1-7/8 1-1/16 1/4 1-17/32
H200-TB 2 3-1/4 1-15/16 1-5/32 1/4 1-31/32
H250-TB 2-1/2 3-3/4 2-9/16 1-9/16 1/4 2-13/32
H300-TB 3 4-3/8 2-21/32 1-19/32 1/4 2-31/32
H350-TB 3-1/2 5 2-23/32 1-5/8 1/4 3-13/32
H400-TB 4 5-1/2 2-23/32 1-5/8 1/4 3-7/8
H500-TB 5 6-7/8 3-1/32 1-15/16 1/4 4-15/16
H600-TB 6 7-11/16 3-5/32 2 1/4 6
Material – Hub and Locknut: zinc or copper free aluminum
Insulating Throat: thermoplastic temp. rating – 105°C, Flammability Rating: – 94V-0
Sealing Ring Nitrile (BUNA “N”)
For Aluminum Hubs add suffix A(i.e. H050A). For Chrome Plated Hubs add suffix CP (i.e. H050CP).
Meets NEMA sealing requirements for NEMA 3R, 4 & 13 enclosures.
U.L. Listed and CSA Certified. CSA Certified use in hazardous locations Class I, Division 2, Class II,
Divisions 1 and 2, Groups E, F and G, Class III, Division 1, 2 and Type 4.
Chrome Plated Hubs (suffix-“CP”) are rated NEMA 4X.
Throat Dia. E
28-29-e.pdf 1 12/28/2012 1:24:58 PM
29
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
T&B Grounding Hub
Dimensions (in.)
AB CDE
Trade Max. Panel Throat
Cat. No. Size Dia. Thickness Dia.
H050GR-C 1/2 17/16 19/16 7/8 3/16 19/32
H075GR-C 3/4 12-1/32 1-19/32 29/32 3/16 25/32
H100GR-C 1 2 1-13/16 1-1/16 1/4 1
H125GR-C 1-1/4 2-3/8 1-7/8 1-1/16 1/4 1-5/16
H150GR-C 1-1/2 2-3/4 1-7/8 1-1/16 1/4 1-17/32
H200GR-C 2 3-1/4 1-15/16 1-15/32 1/4 1-31/32
H250GR-C 2-1/2 3-3/4 2-9/16 1-9/16 1/4 2-13/32
H300GR-C 3 4-3/8 2-21/32 1-19/32 1/4 2-31/32
H350GR-C 3-1/2 5 2-23/32 1-5/8 1/4 3-13/32
H400GR-C 4 5-1/2 2-23/32 1-5/8 1/4 3-7/8
H500GR-C 5 6-7/8 3-1/32 1-15/16 1/4 4-15/16
H600GR-C 6 7-11/16 3-5/32 2 5/16 6
Material—Hub and Locknut: zinc or copper-free aluminum.
Insulating Throat: thermoplastic temp. rating—105°C;
flammability rating:—94V-0.
Sealing Ring: Nitrile (BUNA “N”)
For Aluminum Grounding Hubs add suffix A(i.e. H050GRA-C).
For Chrome Plated Hubs add suffix CP (i.e. H050GRCP).
For 316 Stainless Steel Hubs add suffix SST (i.e. H050GRSST).
For PVC coating add suffix PVC (i.e. H050GRPVC-C).
Meets NEMA sealing requirements for NEMA 3R, 4 & 13 enclosures.
U.L. Listed and CSA Certified.
CSA approved for use in hazardous locations: Class I, Division 2, Class II, Divisions 1 & 2,
Groups E, F & G, Class III, Division 1, 2 and Type 4.
T&B Grounding and Bonding Locknut
Max.
Trade A B Ground Conductor
Cat. No. Size Dia. Height Screw Size
L050GR-C 1/2 1-1/2 13/32 #10-32 x 1/4” #10
L075GR-C 3/4 1-11/16 13/32 #10-32 x 1/4” #10
L100GR-C 1 2 13/32 #10-32 x 1/4” #10
L125GR-C 1-1/4 2-3/8 15/32 1¼4-20 x 1/4” #10
L150GR-C 1-1/2 2-3/4 15/32 1¼4-20 x 5/16” #8
L200GR-C 2 3-1/4 15/32 1¼4-20 x 5/16” #8
L250GR-C 2-1/2 3-3/4 11/16 1¼4-20 x 5/16” #6
L300GR-C 3 4-3/8 23/32 1¼4-20 x 5/16” #6
L350GR-C 3-1/2 5 23/32 1¼4-20 x 5/16” #6
L400GR-C 4 5-1/2 23/32 1¼4-20 x 5/16” #4
L500GR-C 5 6-5/8 23/32 3¼8-16 x 3/8” #2
L600GR-C 6 7-11/16 23/32 3¼8-16 x 3/8” #1
Material—Locknut: zinc or copper-free aluminum
For Aluminum Locknuts add suffix A. (i.e. L050GRA-C)
For Chrome Plated Locknuts add suffix CP. (i.e. L050GR-CP)
For 316 Stainless Steel Locknuts add suffix SST (i.e. L050GRSST).
Grounding Locknut for Hubs
Throat Dia.
B
E
C
A
28-29-e.pdf 2 12/28/2012 1:24:59 PM
30
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
T&B Bulkhead Fittings
Bulkhead Fitting
Trade
Cat. No. Size
H050BHD 1/2”
H075BHD 3/4”
H100BHD 1”
H125BHD 1-1/4”
H150BHD 1-1/2”
H200BHD 2”
H250BHD 2-1/2”
H300BHD 3”
H350BHD 3-1/2
H400BHD 4”
H500BHD 5”
H600BHD 6”
Thru Bulkhead Fitting
Trade
Cat. No. Size
H050TBF 1/2”
H075TBF 3/4”
H100TBF 1”
H125TBF 1-1/4”
H150TBF 1-1/2”
H200TBF 2”
Thru Bulkhead Hub
Trade
Cat. No. Size
H050TBH 1/2”
H075TBH 3/4”
H100TBH 1”
H125TBH 1-1/4”
H150TBH 1-1/2”
H200TBH 2”
Trade Across
Size Thread Height Diameter Flats A B
1/2” 1/2”-14 1-13/32 1-7/16 1 3/4 1/2
3/4” 3/4”-14 1-15/32 1-11/16 1-1/4 25/32 17/32
1” 1”-11-1/2 1-11/16 2 1-17/32 29/32 19/32
1/4” 1-1/4”-11-1/2 1-25/32 2-3/8 1-27/32 29/32 21/32
1-1/2” 1-1/2”-11-1/2 1-13/16 2-3/4 1-1/8 29/32 21/32
2” 2”-1-1/2 1-27/32 3-1/4 2-5/8 15/16 21/32
2-1/2” 2-1/2”-8 29/32 3-3/4 3-1/8 17/32 7/8
3” 3”-8 2-9/16 4-3/8 3-25/32 15/16 29/32
3-1/2” 3-1/2”-8 2-9/16 5 4-9/32 1-3/8 7/8
4” 4”-8 2-9/16 5-1/2 4-27/32 1-3/8 7/8
5” 5”-8 2-23/32 6-5/8 5-29/32 1-15/32 7/8
6” 6”-8 3 7-11/16 7-1/32 1-1/2 31/32
Material—Hub, Body and Locknut: zinc or copper-free aluminum
Insulating Throat: thermoplastic temp. rating—105°C; Flammability rating:—94V-0
Sealing Ring: Nitrile (BUNA “N”)
For Aluminum Bulkhead add suffix A.
For Chrome Plated Bulkhead add suffix CP.
Nipple Nut
Not Included
Across Flats
Height
Diameter
Thread
CONFITMRO_EN_ALL.pdf 30 11/28/2011 11:05:23 AM
31
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
Offset Reducers
Trade Dimensions (in.)
Cat. No. Size Height Dia. (Ø) A B C D E
H150-075ORGR-TB 1-1/2”-3/4” 1-21/32 2-3/4 15/16 23/32 1-29/32 1-9/32 11/32
H150-100ORGR-TB 1-1/2”-1” 1-25/32 2-3/4 1-1/16 23/32 1-29/32 1-9/16 7/32
H150-125ORGR-TB 1-1/2”-1-1/4” 1-25/32 2-3/4 1-1/16 23/32 1-29/32 1-7/8 1/32
H250-200ORGR-TB 2-1/2”-2” 2-1/8 3-3/4 1-3/16 15/16 2-29/32 2-21/32 3/32
Material—Offset Reducer and Locknut: zinc or copper-free aluminum
Insulating Throat: thermoplastic temp. rating—105°C; Flammability rating—94V-0
Sealing Ring: Nitrile (BUNA “N”)
For Aluminum Offset Reducer add suffix A. (i.e. H150-125ORGRA-TB)
For Chrome Plated Offset Reducer add suffix CP. (i.e. H150-125ORGRCP-TB)
Capoffs
Trade Dimensions (in.)
Cat. No. Size Height Diameter A B C
H050CAP 1/2” 1-13/32 1-7/16 19/32 27/32 3/16
H075CAP 3/4” 1-15/32 1-11/16 19/32 1-1/16 3/16
H100CAP 1” 1-11/16 2 11/16 1-5/16 1/4
H125CAP 1-1/4” 1-25/32 2-3/8 23/32 1-21/32 1/4
H150CAP 1-1/2” 1-13/16 2-3/4 23/32 1-29/32 1/4
H200CAP 2” 1-27/32 3-1/4 23/32 2-3/8 1/4
H250CAP 2-1/2” 2-9/32 3-3/4 7/8 2-29/32 1/4
H300CAP 3” 2-9/16 4-3/8 7/8 3-1/32 11/32
H350CAP 3-1/2” 2-9/16 5 29/32 4-1/32 11/32
H400CAP 4” 2-9/16 5-1/2 29/32 4-1/2 11/32
H500CAP 5” 2-23/32 6-5/8 29/32 5-9/16 11/32
H600CAP 6” 3 7-5/8 31/32 6-5/8 11/32
Material—Capoff and Locknut: zinc or copper-free aluminum
Insulating Throat: thermoplastic temp. rating—105°C; flammability rating—94V-0
Sealing Ring: Nitrile (BUNA “N”)
For Aluminum Capoff add suffix A. (i.e. H050CAPA)
For Chrome Plated Capoff add suffix CP. (i.e. H050CAPCP)
Dia. (Ø)
Height
Capoff
Height
Dia. (0)
Dia.
A
C
B
C
B
A
E
CONFITMRO_EN_ALL.pdf 31 11/28/2011 11:05:23 AM
32
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
Threadless Fittings/Couplings
(For Threadless Rigid Metal Conduit and Intermediate Metal Conduit)
Application
To connect and effectively bond
threadless rigid metal
conduit/intermediate metal conduit to
a box or enclosure, or to couple ends
of threadless conduit.
Features
Steel/Malleable Iron Construction.
Case hardened ring bites into
conduit for high quality continuity and
grip.
Nylon insulator firmly secured in place
protects conductors and reduces
wire pulling effort by as much as
50%; prevents thread damage in
handling.
Case hardened steel locknut or
malleable iron locknut designed
to provide a positive bond.
Suitable for concrete tight application.
Raintight application.
Capable of carrying ground fault
currents up to 10,000 amps RMS
(1/2" through 1-1/2” size) and 20,000
amps RMS (2” and above sizes)
duration of current 3 cycles.
Standard Material
Nut, Gland 1/2” to 1” Steel—1-1/4”
to 4” Malleable Iron
Body All Malleable Iron
Ring Steel (case hardened)
Insulator Nylon
Locknut 1/2” thru 2” Steel
(hardened) 2” thru 4”
Malleable Iron
Standard Finish
Electro Zinc Plated & Chromate
Coated
Range
8123 & 8120 Series 1/2 through 4”
Size Conduit
8130 Series 1/2” and 3/4”
Size Conduit
All hub threads Straight Pipe
(NPS)
Conformity
U.L. 514B
CSA C22.2 No. 18.3
ANSI C80.4
NFPA 70-2008 (ANSI)
NEMA FB-1
Federal Specification W-F-408
Federal Standard H-28 (Threads)
8123 Series
8130 Series
8120 Series
CONFITMRO_EN_ALL.pdf 32 11/28/2011 11:05:23 AM
33
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
Nylon Insulated Threadless Fittings
Cat. No. Conduit Dimensions (in.)
Nylon Insul. Non-Insul. Size A B C
8123 8121 1/2” 1-11/32 1-15/16 3/4
8223 8221 3/4” 1-5/8 2 3/4
8323 8321 1” 1-7/8 2-7/16 7/8
8423 8421 1-1/4” 2-3/8 2-9/16 11/16
8523 8521 1-1/2” 2-5/8 2-3/4 3/4
8623 8621 2” 3-1/4 2-15/16 27/32
8723-TB 8721 2-1/2” 3-15/16 3-15/16 1-1/8
8823-TB 8821 3” 4-11/16 4-1/8 1-7/32
8853 8851 3-1/2” 5-3/16 4-1/4 1-1/8
8973 8971 4” 5-11/16 5 1-1/8
For Dura-Plate™ finish, add prefix 040- to Cat. No. Consult Customer Service for details.
Threadless Couplings
Dimensions (in.)
Cat. No. Size A B
8120 1/2” 1-9/32 2
8220 3/4” 1-19/32 2-5/16
8320 1” 1-7/8 2-11/16
8420 1-1/4” 2-3/8 2-13/16
8520 1-1/2” 2-5/8 3-5/8
8620 2” 3-1/4 3-13/16
8720 2-1/2” 3-15/16 5-3/8
8820 3” 4-11/16 5-1/2
8850 3-1/2” 5-3/16 5-1/2
8970 4” 5-11/16 5-1/2
For Dura-Plate™ finish, add prefix 040- to Cat. No. Consult Customer Service for details.
A split steel ring with diagonal serrations grips the
conduit and bites into it for positive ground.
Makes a permanent connection and eliminates
the need for cutting a thread on the conduit.
Insulation helps to guarantee continuity of
service with protection of the conductor at the
critical point—the fitting bushing. Malleable iron
construction.
Eliminate conduit threading. When tightened
with a wrench they make a U.L. Listed and CSA
Certified concrete-tight connection.
Malleable iron.
CONFITMRO_EN_ALL.pdf 33 11/28/2011 11:05:23 AM
34
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
Threadless Short Elbows—Nylon Insulated
Dimensions (in.)
Cat. No. Size A B C
8130 1/2” 1-11/32 1-1/2 1/2
8131 3/4” 1-5/8 1-3/4 9/16
8132 1” 1-7/8 1-15/16 11/16
8134 1-1/2” 2-23/32 3-1/8 13/16
For Dura-Plate™ finish, add prefix 040- to Cat. No. Consult Customer Service for details.
Ideal for entering enclosure or conduit body at right
angles. Eliminates need to thread conduit. As with
straight couplings, this fitting makes a concrete-
tight connection. Malleable iron.
CONFITMRO_EN_ALL.pdf 34 11/28/2011 11:05:23 AM
35
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
Specifications — Set Screw Fitting/Coupling
(For Threadless Rigid Metal Conduit and Intermediate Metal Conduit)
Application
To connect and effectively bond threadless rigid metal conduit or intermediate
metal conduit to a box or enclosure or to couple ends of threadless conduit.
Features
Thickwall steel or malleable iron body.
Hardened hex head cup point screw to provide high quality bond.
Captive screw, will not vibrate loose.
Nylon insulated throat meets and exceeds all codes requirements for bushing:
(i) Prevents thinning of insulation.
(ii) Reduces installation effort.
(iii) Prevents first thread damage.
Coupling provided with positive center stop.
Suitable for concretetight application.
Capable of carrying ground fault currents up to 10,000 amps RMS
(1¼2 through 1-1/2” size) and 20,000 amps RMS (2” and above sizes).
Standard Material
Body 1/2” thru 2” Steel
2-1/2” thru 4” Malleable Iron
Locknut 1/2” thru 2” Steel (hardened)
2-1/2” thru 4” Malleable Iron
Screw Steel (hardened)
Insulator Nylon
Standard Finish
Electro Zinc Plated & Chromate Coated.
Conformity
U.L. 514B
CSA C22.2 No. 18.3
ANSI C80.4
NFPA 70-2008 (ANSI)
NEMA FB-1
Federal Specification W-F-408
Federal Standard H-28 (Threads)
8125 Series
8124 Series
CONFITMRO_EN_ALL.pdf 35 11/28/2011 11:05:23 AM
36
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
Insulated Set-Screw Fitting
Conduit Dimensions (in.)
Cat. No. Size A B
8125 1/2” 1-3/8 13/32
8225 3/4” 1-1/2 7/16
8325 1” 1-13/16 35/65
8425 1-1/4” 2 5/8
8525-TB 1-1/2” 2-5/16 5/8
8625 2” 2-7/16 11/16
8725-TB 2-1/2” 3-3/8 1
8825 3” 3-7/16 1
8855 3-1/2 3-7/8 1-1/16
8975 4” 4-3/16 1-1/8
Sizes 1/2”-2” made of steel. Sizes 2-1/2”-4” are malleable iron.
For Dura-Plate™ finish, add prefix 040- to Cat. No. Consult Customer Service for details.
Set Screw Coupling
Conduit Dimensions (in.)
Cat. No. Size A
8124 1/2” 2-1/2
8224-TB 3/4” 2-11/16
8324-TB 1” 2-27/32
8424 1-1/4” 3
8524 1-1/2” 3-3/8
8624 2” 3-5/8
8724-TB 2-1/2” 3-7/8
8824-TB 3” 4-1/4
8854 3-1/2 4-15/16
8974 4” 5-3/8
Sizes 1/2”-2” made of steel; sizes 2-1/2”-4” are malleable iron.
For Dura-Plate™ finish, add prefix 040- to Cat. No. Consult Customer Service for details.
Eliminate conduit threading with these set
screw fittings. Captive hex head screws tighten
down onto conduit for positive holding strength
and ground. The fittings are furnished with
insulated throats reducing wire pulling effort by
as much as 50%. Approved concrete-tight.
Eliminate the need for threading conduit ends
when joining rigid conduit with these set screw
couplings. Captive hex head screws provide
positive holding strength and ground continuity.
Approved concrete-tight.
CONFITMRO_EN_ALL.pdf 36 11/28/2011 11:05:23 AM
37
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
Bushed Elbows
Dimensions (in.)
Cat. No. Size A B C
460TB 1/2” 1-13/16 1-1/8 5/8
461TB 3/4” 2-1/4 1-1/2 9/16
462 1” 2-23/32 1-23/32 11/16
463 1-1/4” 3-1/8 2-1/16 25/32
For Dura-Plate™ finish, add prefix 040- to Cat. No. Consult Customer Service for details.
Short Elbows—Nylon Insulated
Dimensions (in.)
Cat. No. Size A B C
4290 1/2” 1-7/32 1-1/4 1/2
4291 3/4” 1-7/16 1-5/16 9/16
4292 1” 1-23/32 1-9/16 11/16
4293 1-1/4” 2-7/32 2-1/16 13/16
4294 1-1/2” 2-15/32 2-3/16 13/16
4295 2” 3 2-9/16 13/16
For Dura-Plate™ finish, add prefix 040- to Cat. No. Consult Customer Service for details.
Not U.L. Listed
Short Elbows
Dimensions (in.)
Cat. No. Size A B C
4250 1/2” 1-5/16 1-1/4 7/16
4251 3/4” 1-17/32 1-5/16 1/2
4252 1” 1-13/16 1-9/16 5/8
4253 1-1/4” 2-9/32 2-1/16 11/16
4254 1-1/2” 2-9/16 2-3/16 11/16
4255 2” 3-3/32 2-9/16 11/16
For Dura-Plate™ finish, add prefix 040- to Cat. No. Consult Customer Service for details.
The noninsulated elbow has smoothly rounded
shoulders to protect conductor insulation.
Malleable iron.
The integral insulation of the insulated elbow is
a guarantee that the bushing of every fitting will
be smooth. Malleable iron.
When an insulated elbow is not desired, the
Noninsulated short elbow should be used.
Malleable iron.
CONFITMRO_EN_ALL.pdf 37 11/28/2011 11:05:24 AM
38
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
Application
To couple and effectively bond
threaded ends of rigid metal conduit/
intermediate metal conduit where
neither length of conduit can be
rotated.
Features
Malleable Iron/Steel/Copper-free
Aluminum Construction.
Free fitting threads ensure easy
assembly.
Permits conduit coupling without
rotating either conduit.
Provides rigid in-line coupling with
high quality grounding; will not loosen
under vibration.
Suitable for concrete-tight application.
Capable of carrying ground fault
currents up to 10,000 amps RMS
(1/2” through 1-1/2” size) and up to
20,000 amps RMS (2” and above)
(duration of fault current 3 cycles)
(674 series tested).
Standard Material
674 Series
Bushing and Body Malleable Iron
Ring Steel up to 2” or
Malleable Iron
675AL Series
Bushing and Body Aluminum
Ring Aluminum
Standard Finish
674 Series: Electro Zinc Plated &
Chromate Coated
675AL Series: Degreased
Range
674 Series: 3/8” thru 6” Conduit
675AL Series: 1/2” thru 6” Conduit
All straight pipe threads (NPS)
Conformity
U.L. 514B
CSA C22.2 No. 18.3
NEMA FB1
ANSI C80.4
NFPA 70-2008 (ANSI)
Federal Specification W-F-408
Federal Standard H-28 (Threads)
Threaded Coupling (ERICKSON®Couplings)
(For Threaded Rigid Metal Conduit and Intermediate Metal Conduit)
674 Series
675AL Series
ERICKSON®Couplings
Cat. No. Dimensions (in.)
Mal. Iron Alum.* Size A B
674 3/8” 1-1/8 1-1/8
675 675AL 1/2” 1-15/32 1-1/4
676 676AL 3/4” 1-9/16 1-13/32
677 677AL 1” 1-29/32 1-5/8
678 678AL 1-1/4” 2-3/8 1-13/16
679 679AL 1-1/2” 2-5/8 1-31/32
680-TB 680AL 2” 3-7/32 2-7/32
681 681AL 2-1/2” 3-3/32 2-11/16
682 682AL 3” 4-7/16 2-29/32
683 683AL 3-1/2” 5 3
684 684AL 4” 5-1/2 3-3/16
685 685AL4-1/2” 6-1/4 3-15/32
686 686AL 5” 6-25/32 3-3/4
687 687AL 6” 8 4-1/32
* Copper-free Aluminum (less than .4% Copper).
U.L. Listed and CSA Certified concrete-tight.
Not CSA Certified.
With an Erickson coupling, a conduit run may be
completed when neither conduit can be turned.
A conduit run may also be broken without taking
down the whole run. Conduit joined with
Erickson Couplings is rigid and in line and
vibration will not loosen the connections.
CONFITMRO_EN_ALL.pdf 38 11/28/2011 11:05:24 AM
39
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
Panel Fitting Extensions
Dimensions (in.)
Cat. No. Size A B C
1440 1/2” 1-1/4 1-3/16 1-7/8
1441 3/4” 1-1/4 1-13/32 1-15/16
1442 1” 1-3/16 1-21/32 1-15/16
1443 1-1/4” 1-1/4 2-1/8 2
Male Enlargers*
Dimensions (in.)
Cat. No. Size A B C
1245 1/2” to 3/4” 1-1/4 1-5/32 1/2
1246 3/4” to 1” 1-17/32 1-9/32 15/32
1244 1” to 1-1/4” 1-7/8 1-7/16 17/32
1247 1-1/4” to 1-1/2” 2-3/16 1-15/32 19/32
For Dura-Plate™ finish, add prefix 040- to Cat. No. Consult Customer Service for details.
Female Reducers*
Dimensions (in.)
Cat. No. Size A B C
1250-TB 3/4” to 1/2” 1-1/8 5/8 3/16
1261 1” to 1/2” 1-7/16 1-7/16 3/16
1251 1” to 3/4” 1-3/8 11/16 3/16
1262 1-1/4” to 1/2” 1-13/16 21/32 3/16
1263 1-1/4” to 3/4” 1-13/16 23/32 3/16
1252 1-1/4” to 1” 1-3/4 25/32 7/32
1253 1-1/2” to 1-1/4” 2 13/16 1/4
1254 2” to 1-1/2” 2-3/8 1-3/16 9/32
1255 2-1/2” to 2” 3 1-1/4 3/8
1256 3” to 2-1/2” 3-5/8 1-1/2 1/2
1257 3-1/2” to 3” 4-1/8 1-9/16 1/2
1258 4” to 3-1/2” 4-5/8 1-3/16 1/2
For Dura-Plate™ finish, add prefix 040- to Cat. No. Consult Customer Service for details.
Ideal when longer thread length is needed. Will
combine with any fitting having a male thread.
Male thread of panel fitting extension is 1” long.
Malleable iron.
Adapt an outlet hole to the next larger size of
conduit. Rough ends of conduit carefully covered
by built-in bushing. Malleable iron.
Adapt any outlet to the next smaller size of
conduit. Hex shoulder makes wrench tightening
convenient. Malleable iron.
CONFITMRO_EN_ALL.pdf 39 11/28/2011 11:05:24 AM
40
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
Threaded Reducers
Cat. No. Dimensions (in.)
Stl. or M.I. Alum. Size A
600-TB 600AL-TB 1/2” to 3/8” 5/8
601-TB 601AL-TB 3/4” to 1/2” 19/32
602-TB 602AL-TB 1” to 1/2” 19/32
603-TB 603AL-TB 1” to 3/4” 19/32
604-TB 604AL-TB 1-1/4” to 1/2” 19/32
605-TB 605AL 1-1/4” to 3/4” 19/32
606-TB 606AL 1-1/4” to 1” 11/16
607 607AL 1-1/2” to 1/2” 15/16
608 608AL 1-1/2” to 3/4” 15/16
609 609AL 1-1/2” to 1” 1-3/32
610 610AL 1-1/2” to 1-1/4” 27/32
611-TB 611AL 2” to 1/2” 23/32
612 612AL 2” to 3/4” 1-1/16
613 613AL 2” to 1” 1-1/16
614-TB 614AL 2” to 1-1/4” 1-1/16
615-TB 615AL 2” to 1-1/2” 27/32
Reducing Washers
Dimensions (in.)
Cat. No. Size A B
3700 3/4” to 3/8” 1-3/8 45/64
3701 3/4” to 1/2” 1-3/8 7/8
3702 1” to 3/8” 1-5/8 45/64
3703 1” to 1/2” 1-5/8 7/8
3704 1” to 3/4” 1-5/8 1-3/32
3705-TB 1-1/4” to 3/8” 2 45/64
3706 1-1/4” to 1/2” 2 7/8
3707 1-1/4” to 3/4” 2 1-3/32
3708 1-1/4” to 1” 2 1-23/64
3709 1-1/2” to 3/8” 2-1/4 45/64
3710 1-1/2” to 1/2” 2-1/4 7/8
3711 1-1/2” to 3/4” 2-1/4 1-3/32
3712 1-1/2” to 1” 2-1/4 1-23/64
3713 1-1/2” to 1-1/4” 2-1/4 1-23/32
3714 2” to 1/2” 2-3/4 7/8
3715-TB 2” to 3/4” 2-3/4 1-3/32
3716 2” to 1” 2-3/4 1-23/64
3717 2” to 1-1/4” 2-3/4 1-23/32
3718 2” to 1-1/2” 2-3/4 1-31/32
For reducing the threaded opening in conduit
bodies or any female threaded fitting. Smooth,
built-in bushing completely covers rough ends
of conduit. Iron or steel construction. Steel from
600-TB thru 606-TB, also 614 & 615.
Washers reduce knockout hole in outlet box.
Newly designed of galvanized steel. These
washers, used in pairs, interlock and form a rib
which centers the washers and conduit in the
knockout.
CONFITMRO_EN_ALL.pdf 40 11/28/2011 11:05:24 AM
41
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
Application
To support and securely fasten rigid
metal conduit and intermediate metal
to the supporting surface.
Features
Rugged malleable iron/copper-free
aluminum construction—snugly fits
on the conduit.
Designed to prevent accumulation of
moisture and start of corrosion on
vertical run of conduit (A).
Standard Material
1275 Series
Malleable Iron
1976AL Series
All copper-free
aluminum
Standard Finish
1275 Series
Hot Dipped Galvanized
1276AL Series
As Cast
Range
1275 Series
3/8” through 6” conduit
1276AL Series
1/2” through 6” conduit
Conformity
CSA C22.2 No. 18.3
ANSI C80.4
NFPA 70-2008 (ANSI)
Conduit
Strap
Conduit
Conduit
Spacer
Supporting
Wall
1275 Series
1276AL Series
Designed to fit each size of conduit snugly. High
reinforcing ribs on each side increase strength,
reduce weight. Hot-dipped galvanized finish.
Conduit Straps
(For Rigid Metal Conduit and Intermediate Metal Conduit)
Pipe Straps—Malleable Iron or Aluminum
Cat. No. Dimensions (in.) Screw
Mal. Iron Alum. Size A B C Size
12751275AL 3/8” 1-15/16” 19/32” 1/4” 1/4”
12761276AL1/2” 2-11/32” 23/32” 1/2” 1/4”
12771277AL3/4” 2-11/16” 21/32” 5/8” 1/4”
12781278AL1” 3-3/32” 11/16” 13/16” 1/4”
12791279AL1-1/4” 4-1/8” 13/16” 29/32” 5/16”
12801280AL 1-1/2” 4-1/2” 15/16” 1-17/32” 3/8”
1281 1281AL 2” 5-3/16” 1-1/8” 1-1/4” 7/16”
1282* 1282AL 2-1/2” 5 -15/16” 1-1/2” 1-3/4” 1/2”
1283* 1283AL 3” 6-11/16” 1-5/8” 2-3/16” 1/2”
1284 1284AL 3-1/2” 7-19/32” 1-3/4” 2-3/4” 5/8”
1285* 1285AL 4” 8-5/16” 1-7/8” 2-13/16” 5/8”
1286** 1286AL** 4-1/2” 9-3/16” 1-15/16” 2-15/16” 5/8”
1287 1287AL 5” 9-15/16” 2” 3-1/4” 5/8”
1288 1288AL 6” 11-1/2” 2-7/16” 4-1/8” 5/8”
* May be used with EMT of same size.
Not snap on type.
U.L. not applicable.
** Not CSA Certified
A
C
B
CONFITMRO_EN_ALL.pdf 41 11/28/2011 11:05:24 AM
Pipe Straps—Steel
Conduit Dimensions (in.) Screw
Cat. No. Size A B C Size
1210C3/8” 1-15/32 3/4 11/16 1/4”
1211C 1/2” 2 3/4 15/16 1/4”
1212C 3/4” 2-5/16 3/4 1” 1/4”
1213C 1” 3-13/16 3/4 1-17/64 1/4”
1214TB* 1-1/4” 2-31/32 1-9/16 1-9/16 3/8”
1215TB* 1-1/2” 3-23/32 1-13/16 1-13/16 3/8”
1216TB* 2” 4-7/16 2-5/16 2-5/16 3/8”
Not snap on type.
U.L. not applicable.
* Not CSA Certified.
Corrosion Resistant PVC Coated Rigid Conduit Straps
Bolt Dimensions (in.)
Cat. No. Size Size A B C
1275CR 3/8” 1/4” 2 21/32 1/4
1276CR 1/2” 1/4” 2-13/32 25/32 1/2
1277CR 3/4” 1/4” 2-3/4 23/32 5/8
1278CR 1” 1/4” 3-5/32 3/4 13/16
1279CR 1-1/4” 3/8” 4-5/32 25/32 7/8
1280CR 1-1/2” 3/8” 4-9/16 1 1-7/32
1281CR 2” 1/2” 5-1/4 1-3/16 1-1/4
U.L. not applicable.
42
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
Elongated bolt hole makes alignment easy, even
when holes in mounting surface are off center.
Snap on features. Steel. Zinc plated
A
B
C
Malleable iron. Designed to fit each size of
conduit snugly. High reinforcing ribs on each
side increase strength, reduce weight.
A
C
B
CONFITMRO_EN_ALL.pdf 42 11/28/2011 11:05:24 AM
43
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
Application
Provides mounting surface for
conduit where installation requires
air space between conduit and
supporting surface.
Features
Prevents conduit rusting from wall
condensation.
Spacers can be stacked one atop
the other facilitating installation and
eliminating expensive conduit off
setting (A).
Designed to cover wide range;
marked with accurate size marking
for proper positioning (B).
Standard Material
1350 Series
Malleable Iron
1350AL Series
Copper-free aluminum
Standard Finish
1350 Series
Hot Dipped Galvanized
1350AL Series
As Cast
Range
1/2” through 6” conduit
Conformity
CSA C22.2 No. 18.3
ANSI C80.4
NFPA 70-2008 (ANSI)
1350 Series
1350AL Series
Conduit Spacers
(For Rigid Metal Conduit, Intermediate Metal Conduit and Electrical Metallic Tubing)
CONFITMRO_EN_ALL.pdf 43 11/28/2011 11:05:25 AM
44
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
Pipe Spacers
Cat. No. Screw Dimensions (in.)
Mal. Iron Alum. Size Size A B
1350 1350AL 3/8”, 1/2”, 3/4”, 1” #7 3” 7/8”
1351 1351AL 1-1/4”-1-1/2”-2” #12 5” 1-3/16”
1352 1352AL 2-1/2”-3” #12 9-9/16” 1-3/4”
1353 1353AL 3-1/2”-4” #14 7-9/16” 2”
1354 1354AL 4-1/2”-5”-6” #16 10-9/16” 2-9/16”
Conforms to CEC Rule 12-012 (5)
U.L. not applicable.
Pipe Spacers—PVC Coated
Conduit Screw Dimensions (in.)
Cat. No. Size Size A B
1350CR 1/2”-3/4”-1” #7 3 7/8
1351CR 114”-1-1/2”-2” #12 5 3/8
1352CR 2-1/2”-3” #12 6-9/16 1-3/4
1353CR 3-1/2”-4” #14 7-9/16 2
1354CR 4-1/2”-5”-6” #16 10-9/16 2-9/16
U.L. not applicable.
Conforms to CEC Rule 12-012 (5)
Used with T&B conduit straps to permit space
between conduit and mounting surface.
Eliminates need for costly offset-bending
conduit and possible corrosive moisture traps
when conduit is mounted directly to a surface.
Hot-dipped galvanized finish, premountable and
stackable to eliminate offsetting.
Corrosion resistant PVC coated malleable iron.
Pre-mountable, stackable to eliminate offsetting.
Spacers can be stacked for offsets on wall or
into outlet box. Prevents conduit rusting from
wall condensation. Eliminates offsetting of
conduit.
CONFITMRO_EN_ALL.pdf 44 11/28/2011 11:05:25 AM
45
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
Tite-Bite®Combination Couplings
Armoured Cable for Threaded Rigid
Dimensions (in.)
Cat. No. Size A B
440-C 1/2” 1-5/8 1-27/32
441 3/4” 1-3/4 2-1/8
442 1” 2 2-17/32
Beam Clamps Adjustable
Cat. No. Description
700TB Fits Flange 2-3/4”-7-3/8”
703* Special Bolt and 3 Nuts
* Not CSA Certified
Conduit Supports
Cat. No. Size
690TB 1/2”
691TB 3/4”
692TB 1”
693TB 1-1/4”
Includes bolts. Steel.
These supports will fit any flange, tapered or
straight up to 5/8” thick. The broad hook holds the
conduit at any desired angle. Holds standard rigid
conduit, E.M.T., or I.M.C. Malleable iron.
A one-piece fitting that couples armoured cable or
flexible conduit to threaded rigid conduit. Tite-Bite
wedge holds conduit securely with a double grip.
With a Chase®nipple, this fitting will connect
flexible conduit to outlet boxes, allowing more
wiring space in the box than the usual fitting.
Malleable iron.
CONFITMRO_EN_ALL.pdf 45 11/28/2011 11:05:25 AM
46
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
Methods of Bonding and Grounding
CONCRETE
TIGHT
CONCRETE
TIGHT
RAIN
TIGHT
Case 1: Where threaded or threadless
conduit terminates into a threadless
opening in a sheet metal box or enclosure
with or without concentric or eccentric
knockouts.
(1) Threaded or threadless rigid metal
conduit or intermediate metal conduit
(2) T&B Series 8123 or 8124
Threadless Fittings
(3) T&B Series 8125 Set Screw Fitting
(4) T&B Series 370 or H050-TB
Sealing Hub (Bullet®Hubs)
(5) T&B Series 140 Locknuts
(6) T&B Series 106 Bonding Locknut
(7) T&B Series 3870 Bonding
& Grounding Bushing
(8) T&B Sta-Kon®or Color-Keyed®lug
Bonding jumper around concentric or eccentric
rings required by CEC Rule 10-614
Threadless opening in a sheet metal box or
enclosure.
Method of Bonding
For 120/208 volts or 120/240 volts circuits
provided no unpunched rings remain around the
knockout.
For under or over 250 volts circuits, service
equipment and hazardous locations (where
applicable) provided no unpunched rings remain
around the knockout.
For under or over 250 volts circuits, service
equipment and hazardous locations (where
applicable) with or without unpunched rings
around the knockout.
CONFITMRO_EN_ALL.pdf 46 11/28/2011 11:05:25 AM
47
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
Case 2: Where threaded or threadless
conduit terminates into a threaded hub in a
cast metal enclosure.
Methods of Bonding
For (1) 120/208 or 120/240 volts
circuits (CEC 10-610)
(2) Over 250 volts circuits
(CEC 10-610)
(3) Service equipment
(CEC 10-604)
(4) Hazardous Locations 18-074
(where applicable)
18-124 (Class I, Zone 1)
18-160 (Class I, Zone 2)
18-218 (Class II, Division 1)
18-268 (Class II, Division 2)
18-316 (Class III, Division 1)
18-366 (Class III, Division 2)
(1) Threaded or threadless rigid
metal conduit or intermediate metal
conduit.
(2) T&B Series 8123 Threadless Fitting
(3) T&B Series 8125 Set Screw Fitting
Methods of Bonding and Grounding (continued)
CONCRETE
TIGHT
CONCRETE
TIGHT
RAIN
TIGHT
Threaded hub in a cast
metal enclosure
CONFITMRO_EN_ALL.pdf 47 11/28/2011 11:05:25 AM
48
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
Methods of Bonding and Grounding (continued)
Threadless opening
in a sheet metal
box or enclosure
Case 3: Where threaded conduit
terminates into a threadless opening in a
sheet metal box or enclosure with no
concentric or eccentric rings remaining
around knockout.
Method of bonding for 120/208 volt or 120/240
volts circuits (other than service equipment).
Method of bonding for over 250 volts circuits
e.g. 600/347 volt systems and those operating
over 600 volts (other than service equipment).
Note: Any of the bonding methods described for service equipment may also be used.
CONFITMRO_EN_ALL.pdf 48 11/28/2011 11:05:25 AM
49
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
Case 3:
(cont’d) Where threaded conduit
terminates into a threadless opening in
a sheet metal box or enclosure with no
concentric or eccentric rings remaining
around knockout.
(1) Threaded rigid metal conduit or
intermediate metal conduit
(2) T&B Series 142 Locknuts
(3) T&B Series 122 Bushing Metallic
(4) T&B Series 222 Bushing Plastic
(5) T&B Series 106 Bonding Locknut
(6) T&B Series 3650 Bonding Wedge
Method of Bonding
For (i) Over 250-volts circuit e.g.
347/600-volts systems and
those operating over 600 volts
(ii) Service equipment
(iii) Hazardous locations where
applicable
Methods of Bonding and Grounding (continued)
or
CONFITMRO_EN_ALL.pdf 49 11/28/2011 11:05:25 AM
50
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
Case 4: Where threaded conduit
terminates into a threadless opening in
a sheet metal box or enclosure with
concentric or eccentric rings remaining
around knockout.
Methods of bonding for under or over
250-volts, for service equipment and for
hazardous locations where applicable.
Note: Bonding jumper required by CEC
Rule 10-614
(1) Threaded rigid metal conduit or
intermediate metal conduit
(2) T&B Series 142 Locknuts
(3) T&B Series 122 Bushing, Metallic
(4) T&B Series 3650 Bonding Wedge
(5) T&B Series 3870 Bonding &
Grounding Bushing
(6) T&B Typical Mechanical or Pressure
Type Fitting
Note: For raintight applications, a sealing
ring, T&B Series 5302, may be used
between outside of box or enclosure and
the outside locknut.
Methods of Bonding and Grounding (continued)
CONFITMRO_EN_ALL.pdf 50 11/28/2011 11:05:25 AM
51
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
Methods of Bonding and Grounding (continued)
Typical Installation Using Bonding and Grounding Bushings
Bonding Service Equipment
(CEC Rule 10-604)
Install Bonding Jumper to Assure Electrical Continuity
Between Isolated Sections of Raceways (CEC Rule 10-614)
Multiple Bonding of Service Raceways Where
Service Entrance Conductors are Paralleled in
Two or More Raceways, CEC Rule 10-614
1 T&B Series 142 Locknut
2 T&B Series 3870 Bonding & Grounding Bushing
(Threaded)
3 T&B Series 5262 Sealing “O” Ring
4 T&B Typical Bolted or Pressure Lug
Suggested Specifications
Insulated grounding and bonding bushing (Series 3870)
Where code requires bonding and grounding of single or
multiple metal conduits, or positive bonding and grounding of
metal conduit to the box, enclosure or auxiliary gutter, the end
of the conduit shall be equipped with an insulated metallic
grounding and bonding bushing such as Series 3870
manufactured by Thomas & Betts.
Grounding and bonding bushings used shall be approved for
the purpose and
(i) Shall be of malleable iron/steel/aluminum construction
adequately protected against corrosion.
(ii) Bushing insulator shall be listed or certified for
150°C/302°F application with a flammability rating of
94V-O. Insulator must be positively locked in place.
SERVICE CONDUITS
GROUND BUS
BUS BAR
SERVICE
ENCLOSURE
(i) Installing bonding jumper around unpunched concentric
or eccentric knockouts in sheet metal box or enclosure
[CEC Rule 10-806].
(ii) Installing bonding jumper in hazardous locations where
‘locknut bushing’ or ‘double locknut’ type of contact is
unacceptable method for bonding purposes
[CEC Rule 18-074]
Bonding required by CEC Rule 10-606
Bonding jumper required by
CEC Rule 10-606
CEC Rule 10-806
Bonding Method per CEC Rule 10-806
Bonding required by CEC Rule 10-604
Bonding Method per CEC Rule 10-806
LOAD SIDE
OF SERVICE
EQUIPMENT
CONFITMRO_EN_ALL.pdf 51 11/28/2011 11:05:26 AM
52
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
Methods of Bonding and Grounding (continued)
Typical Installation Using Thomas &Betts Bonding locknut
(1) T&B Series 142 Locknut
(2) T&B Series 106 Bonding Locknuts
(3) T&B Series 122 Bushing
Suitable for Bonding Raceway, EMT
or Terminating Fitting to a sheet
metal box or enclosure where
(a) No unpunched concentric or
eccentric rings remain around the
knockout.
(b) Ordinary locknut is unacceptable
for bonding purposes such as
(i) Service Equipment
Enclosures CEC Rule 10-614
(ii) Bonding for circuits over
250 volts (where required)
CEC Rule 10-614
(iii) Bonding in Hazardous
Locations regardless
of the voltage of the system
CEC Rule 18-074
Suggested Specifications
Bonding Type Locknut (Series 106)
Where drawings indicate installation of a
bonding type locknut to effectively bond
a terminating fitting or metal conduit to a
cabinet, box, enclosure or an auxiliary
gutter, the locknuts installed shall be of
hardened steel/malleable iron
construction, electro-zinc plated, such
as Series 106 manufactured by Thomas
& Betts.
CONFITMRO_EN_ALL.pdf 52 11/28/2011 11:05:26 AM
53
T&B Conduit Fittings
Rigid and Intermediate Metal Conduit Fittings
Methods of Bonding and Grounding (continued)
Typical Installations Using Thomas & Betts Bonding and Grounding Wedge
T&B Series 3651
Bonding & Grounding Wedge
(1) T&B Series 142 Locknut
(2) T&B Series 122 Metallic Bushing
(3) T&B Series 3651 Bonding &
Grounding Wedge
(4)T&B Pressure (crimp type)
Terminal Lug.
Grounding electrode
Conductor enclosure
(Rigid Metal Conduit or
Intermediate Metal Conduit)
Service Enclosure
Service Equipment
Bonding Jumper
Equipment Bonding Jumper
Phase Conductors
Grounding electrode
conductor
Threaded Rigid Metal Conduit
or intermediate Rigid Metal Conduit
Sheet Metal Box or
Enclosure with unpunched
concentric or eccentric
rings remaining around
knockout opening.
Ground Bus
Acceptable Method for Bonding
Following
(i) Service Equipment
CEC Rule 10-614
(ii) Bonding for Circuits over 250 volts
CEC Rule 10-614
(iii) Bonding in Hazardous Locations
CEC Rule 18-074
When installed with a bonding jumper,
acceptable method of bonding where
unpunched rings remain around
concentric or eccentric knockouts in
sheet metal boxes or enclosures.
[CEC Rule 10-614].
Suggested Specifications
Bonding and Grounding Wedge
(Series 3650)
Bonding and Grounding Wedges
installed to effectively bond terminating
fitting or metal conduit to a cabinet, box,
enclosure or an auxiliary gutter or to
install bonding jumper around
concentric or eccentric knockouts shall
be of the type as manufactured by
Thomas & Betts—Series 3650.
Bonding and Grounding Wedge
shall be of rugged bronze/tin plated or
steel/electro-zinc plated.
CONFITMRO_EN_ALL.pdf 53 11/28/2011 11:05:26 AM
54
T&B Conduit Fittings
Electrical Metallic Tubing (EMT) Fittings
Specifications Electrical Metallic Tubing (EMT)
Ref. CEC Rule 12-1400 not exceeding
750 Volts
Electrical Metallic Tubing (EMT) is similar to
rigid steel conduit but is much lighter,
weighing approximately 40 percent as
much as rigid steel conduit of the same
nominal size. EMT can be used for both
exposed or concealed work provided that,
during installation or afterwards, it is not
subjected to severe physical damage. Use
of EMT is restricted to systems not
exceeding 600 volts and to non-
hazardous locations except for Class II
Division 2, acceptable in Class III
Division 1 and Division 2 per CEC Rule
18-302 (1).
Galvanized Steel EMT installed in
concrete, on grade or above, generally
requires no supplementary corrosion
protection. However, when installed
in concrete below grade level and in
contact with soil or cinders,
supplementary corrosion protection
consisting of a protective coating of
bitumastic or asphalt base paint or plastic
is generally applied. EMT run in or under
permanently moist cinder fill must be
encased in at least two inches of cinder-
free concrete unless the conduit is at least
18 inches below the fill.
Aluminum EMT cannot be directly
embedded in concrete containing
soluble chlorides such as calcium
chloride, unwashed beach sand, sea
water or coral bearing aggregates.
When adequately treated with a
protective coating of bitumastic or asphalt
base paint or plastic coating, the
raceway can be installed in concrete
containing chlorides.
In wet locations where walls are
frequently washed or where there are
surfaces of absorbent material, the entire
wiring system, including boxes, fittings,
conduits and cables, must be supported
such that there is at least 1/4 inch air
space between it and the supporting
surface.
Fittings and couplings are required to
be of concrete tight type when
embedded in masonry or concrete or in
dry locations and of the raintight type
when installed in wet locations (CEC
Rule 12-1410).
Where No. 4 or larger underground
conductors enter or leave a conduit, an
insulating bushing with a smooth
well-rounded insulating surface must be
provided to protect conductors unless the
terminating fitting is equipped with an
insulated throat, firmly secured in place
providing equivalent protection. The
insulating bushing or insulating material
must have a temperature rating of not less
than the insulation temperature rating of
installed conductors.
CEC Rule 12-3022 requires that
the raceways be metallically joined
together into a continuous electric
conductor and must be mechanically
connected to all boxes, fittings and
cabinets as to provide effective
electrical continuity.
EMT is not permitted to be threaded.
Cut ends of tubing are required to be
reamed. Code requires that EMT be
adequately supported and restricts bends
in one run to the equivalent of four quarters
or 360 degrees total.
Portions of this section reprinted by
permission from the Canadian Electrical
Code 2009 Part I.
For further details and complete
information please refer to the following:
1. NEC Article 358…Electrical Metallic
Tubing
2. ANSI C80.3…Electrical Metallic
Tubing, Zinc Coated
3. U.L.797…Standards for Safety,
Electrical Metallic Tubing
4. ANSI C80.4…Fittings for Rigid
Metal Conduit and Electrical
Metallic Tubing
5. U.L. 514, Standards for Safety,
Outlet Boxes and Fittings
6. WW-C-563…Conduit, Metal, Rigid,
and Bend and Elbow, Electrical
Conduit, Thinwall Type (EMT)
7. W-F-408…Fittings for Conduit,
Metal, Rigid, (Thickwall & Thinwall
(EMT) Type)
8. NEMA FB-1…Standards
Publication, Fittings and Supports
for Conduit & Cable Assemblies
9. CEC Section 12-1400…Electrical
Metallic Tubing
10.CSA C22.2 No. 83…Safety
Standards for Electrical
Metallic Tubing
11.CSA C22.2 No. 18…Safety
Standards for Outlet Boxes,
Conduit Boxes and Fittings
Please Note
The excerpts and other material herein, whether relating to the Canadian
Electrical Code 2002 Part I, the Underwriters Laboratories, Inc. listing, to
industry practice or otherwise, is not intended to provide all relevant
information required for use and installation. Reference to original or primary
source material and data is mandatory before any application or use is made of
the product.
CONFITMRO_EN_ALL.pdf 54 11/28/2011 11:05:26 AM
55
T&B Conduit Fittings
Electrical Metallic Tubing (EMT) Fittings
Suggested Specifications for Electrical Metallic Tubing (EMT)
Fittings
Series 5123 Insulated
EMT Fitting (Raintight)
(Compression Type)
Series 5120
EMT Coupling (Raintight)
(Compression Type)
Series 1350 Pipe Spacers
Series 106
Bonding Locknut
Series 4176
Pipe Straps
Ferrous Electrical Metallic Tubing (EMT)
shall be of the hot dipped
galvanized type conforming to
applicable specifications WW-563/ANSI
C80.3/U.L. 797/CSA C22.2 No. 83.
EMT protected solely by enamel shall
not be used.
Where lengths of EMT are coupled
together or connected to boxes or
enclosures or where EMT is coupled to
threaded rigid metal conduit or IMC,
fittings approved for intended
applications shall be used, and:
(1) Shall be of rugged steel/malleable
iron construction electro-zinc
plated inside/outside including
threads. Fitting throat shall be
bushed with a nylon insulator.
(2) Shall be of raintight type for
installations exposed to weather or
wet locations such as Thomas &
Betts series 5123, 5120 and 530.
Raintight type fittings may be substituted
for concrete tight application.
Where electrical metallic tubing and
associated fittings are used as part
of equipment grounding system:
(1) A bonding type locknut such
as Thomas & Betts series 106
shall be installed where hub
type fitting terminates into a
threadless opening
(2) Compression ring type fittings
such as Thomas & Betts series
5123 and 5120 shall be used
for terminating and coupling.
EMT shall be securely fastened in place
at intervals as specified by the code
using straps, hangers and other
supporting assemblies as indicated on
plans, and as manufactured by Thomas
& Betts, series 4176 straps. In wet
locations or where supporting surfaces
are of absorbent materials vertical and
horizontal runs of conduit shall be firmly
supported such that there is at least
1/4” air space between conduit and
supporting surface
Spacers and supporting straps shall be
of rugged malleable iron or steel
construction, hot dipped galvanized,
and conforming to requirements of
Canadian Standards Association
Standard C22.2 No. 18.3 as
manufactured by Thomas & Betts,
series 4176 straps and series 1350
spacers.
CONFITMRO_EN_ALL.pdf 55 11/28/2011 11:05:26 AM
56
T&B Conduit Fittings
Electrical Metallic Tubing (EMT) Fittings
Specifications Fittings for Electrical
Metallic Tubing (EMT) Compression Type, Raintight
Application
To connect and effectively bond
electrical metallic tubing to a box
or an enclosure.
To provide a raintight connection
between tubing and the fitting.
To couple ends of tubing.
Features
Rugged all steel construction.
Rings designed to positively bond
conduit to fitting; unique locknut
design provides effective bond
between fitting and box or enclosure;
ground continuity is assured.
Nylon insulator firmly secured in
place—protects conductors, reduces
wire pulling effort and prevents thread
damage in handling.
Locknuts are designed with extended
reach to lock fitting on to a thin box
or an enclosure.
Locknuts tighten without deformation;
will not vibrate loose.
Standard Material
All Steel except Insulator.
Insulator Thermoplastic, U.L.
Rated 105°C
Standard Finish
All Steel Parts Electro Zinc Plated
& Chromate Coated
Insulator As Molded
Range
Conduit Size 1/2” thru 2”
Hub Size 1/2” thru 2” NPS
Hubs provided with straight pipe
threads NPS.
Conformity
U.L. 514B
CSA 22.2 No. 18.3
NFPA 70-2008 (ANSI)
NEMA FB-1
Federal Specification W-F-408
Federal Standard H-28 (Threads)
5123 Series*
* 4230 Series—90° Fittings
5120 Series
CONFITMRO_EN_ALL.pdf 56 11/28/2011 11:05:27 AM
57
T&B Conduit Fittings
EMT Fittings
EMT Fittings—Nylon Insulated
Dimensions (in.)
Cat. No. Size A B
5123 1/2” 1-3/64 1-21/32
5223 3/4” 1-21/64 1-27/32
5323 1” 1-11/16 1-7/8
5423 1-1/4” 2-1/16 2-11/32
5523 1-1/2” 2-5/16 2-23/32
5623 2” 2-25/32 2-13/16
U.L. Listed and CSA Certified raintight.
EMT Couplings
Dimensions (in.)
Cat. No. Size A B
5120 1/2” 1-1/16 1-27/32
5220 3/4” 1-5/16 2-1/8
5320 1” 1-11/16 2-1/8
5420 1-1/4” 2-1/16 2-29/32
5520 1-1/2” 2-5/16 3-1/16
5620 2” 2-3/4 3-7/32
U.L. Listed and CSA Certified raintight.
EMT Fittings
Dimensions (in.)
Cat. No. Size A B
5121-TB 1/2” 1-1/16 1-9/16
5221 3/4” 1-5/16 1-21/32
5321 1” 1-11/16 1-3/4
5421 1-1/4” 2-1/16 1-11/32
5521-TB 1-1/2” 2-5/16 2-9/16
5621 2” 2-3/4 2-3/4
U.L. Listed and CSA Certified raintight.
T&B E.M.T. (thinwall) fittings comply with Federal Spec. WF408B.
Across
Corners
Across
Corners
CONFITMRO_EN_ALL.pdf 57 11/28/2011 11:05:27 AM
58
T&B Conduit Fittings
EMT Fittings
Short Elbows—Insulated
Dimension (in.)
Cat. No. Size A B C
4240 1/2” 1-7/8 1-1/8 11/16
4241-TB 1/2” 1-11/16 1-3/8 1/2
4242 1” 1-7/8 1-5/8 5/8
4243-TB 1-1/4” 2-3/4 2-5/16 11/16
4244 1-1/2” 3-1/16 2-5/8 11/16
4245 2” 3-3/8 3-7/32 3/4
U.L. Listed and CSA Certified raintight.
Short Elbows Malleable Iron
Dimension (in.)
Cat. No. Size A B C
4230 1/2” 1-7/16 1-9/32 7/16
4231 3/4” 1-11/16 1-19/32 1/2
4232 1” 1-7/8 1-27/32 5/8
4233 1-1/4” 2-3/4 2-15/32 11/16
4234 1-1/2” 3-1/16 2-3/4 11/16
4235 2” 3-3/8 3-5/16 11/16
U.L. Listed and CSA Certified raintight.
Combination Coupling—Steel
Dimension (in.)
Cat. No. Size A B
530-TB 1/2” 1-3/8 1-1/16
531 3/4” 1-1/2 1-11/32
532 1” 1-19/32 1-21/32
U.L. Listed and CSA Certified raintight.
Ideal for cramped locations or tight corners
where large radius conduit elbows will not fit or
would appear unworkmanlike. Shoulders on
body of 1/2” size are hex-shaped to provide
positive holding for standard installation
tools. Use insulated type for simple, and safe,
installations. Malleable iron. CSA rated 105°C.
Ideal for cramped locations or tight corners
where large radius conduit elbows will not fit or
would appear unworkmanlike. Shoulders on
body of 1/2” size are hex-shaped to provide
positive holding for standard installation tools.
For connecting EMT to threaded rigid and
intermediate metal conduit.
Across
Corners
CONFITMRO_EN_ALL.pdf 58 11/28/2011 11:05:27 AM
59
T&B Conduit Fittings
EMT Fittings
Pipe Straps—Steel
Dimensions (in.)
Cat. No. Size A B C (Bolt Hole)
4159C 1/2” 1-27/32 3/4 1/4
4160C 3/4” 2-1/32 3/4 1/4
4161C 1” 2-11/32 3/4 1/4
4162* 1-1/4” 2-7/8 3/4 1/4
4163* 1-1/2” 3-11/16 1-1/4 11/32
4164* 2” 4-1/16 1-1/8 13/32
Not U.L. Listed
*Not CSA
Conform to CEC 12-1404
Pipe Straps—Malleable Iron
Dimensions (in.)
Cat. No. Size A B C (Bolt Hole)
4176 1/2” 2-5/32 2-1/32 1/4
4177 3/4” 2-9/16 1-1/16 1/4
4178 1” 3 3/4 1/4
4179 1-1/4” 3-3/4 1-3/16 5/16
4180 1-1/2” 4-3/16 1-5/16 3/8
4181 2” 5-3/16 1-1/8 7/16
1282* 2-1/2” 5-15/16 1-1/2 1/2
1283* 3 6-11/16 1-5/8 1/2
1284* 3-1/2 7-19/32 1-3/4 5/8
1285* 4” 8-5/16 1-7/8 5/8
Not U.L. Listed.
*Not CSA
Conforms to CEC 12-1404
Pipe Spacers
Dimensions (in.)
Cat. No. Size A B
1350 1/2”, 3/4”, 1” 3” 7/8”
1351 1-1/4”,1-1/2”, 2” 5” 1-3/16”
1352 2-1/2”, 3” 9-9/16” 1-3/4”
1353 3-1/2”, 4” 7-9/16” 2”
1354 4-1/2”, 5”, 6” 10-9/16” 2-9/16”
Conforms to CEC 12-012 (5).
Oval Hole for Screw Size (C)
Elongated bolt hole makes alignment easy, even
when holes in mounting surface are out of
alignment. Snap on features hold strap in place.
Oval Hole for Screw Size (C)
Designed to fit each size of conduit snugly. High
reinforcing ribs on each side increase strength,
reduce weight. Hot dipped galvanized finish.
Used with T&B conduit straps to permit space
between conduit and mounting surface. Eliminates
need for costly offset-bending conduit and possible
corrosive moisture traps when conduit is mounted
directly to a surface. Malleable iron. Hot-dipped
galvanized finish, pre-mountable and stackable to
eliminate offsetting.
CONFITMRO_EN_ALL.pdf 59 11/28/2011 11:05:27 AM
60
T&B Conduit Fittings
Flexible Cord and Cable Fittings
Hard Junior Hard Vacuum
Service Cord Service Cord Cleaner Cord
1. Use Extra Hard Hard Light
Pendant, Portable Pendant, Portable Pendant, Portable
2. Voltage Rating Up to 600 volts Up to 300 volts Up to 300 volts
3. Conductor Material Copper (Stranded) Copper (Stranded) Copper (Stranded)
4. Type Designation
(Depends on Jacket Material)
i. Rubber Jacket Type S Type SJ Type SV
ii. Oil Resistant Rubber Jacket Type SO Type SJO Type SVO
iii. Thermoplastic Jacket Type ST Type SJT Type SVT
iv. Oil Resistant
Thermoplastic Jacket Type STO Type SJTO Type SVTO
Please Note
The excerpts and other material herein, whether relating to the Canadian Electrical
Code 2009 Part I, the Underwriters Laboratories, Inc. listing, to industry practice or
otherwise, is not intended to provide all relevant information required for use and
installation. Reference to original or primary source material and data is mandatory
before any application or use is made of the product.
Specifications Flexible Cord and Cables
Ref. CEC Section 4 (Conductors)
The Canadian Electrical Code,
Flexible
Cords
are known by their trade names
“Hard Service Cord,” “Junior Hard Service
Cord” and “Vacuum Cleaner Cord.”
Depending on jacket material, flexible
cords listed are suitable for use where
immersed in water or where occasionally
or continuously in contact with oil or
immersed in oil, or outdoors and in mobil-
homes and recreational vehicles.
Flexible cord is permitted by Code for
use in portable appliances or stationary
equipment requiring movement for service
and repair and for wiring in cranes, hoists
and elevators. Flexible cord is also
permitted to be used to prevent
transmission of noise or vibration.
Flexible cord is not permitted as a
substitute for fixed wiring of structures or
where concealed behind building walls,
ceilings or floors. Running flexible cord
through holes in walls, ceilings, floors or
through doorways, windows or similar
openings is also prohibited.
CEC Section 4 requires that flexible
cords be so connected to devices and
to fittings that tension is not transmitted
to joints or terminal screws. Use of
suitable strain relief fittings designed for
the purpose is one of the
recommended alternatives.
Please refer to the following for further
details and complete information:
1. U.L. 62, ANSI C33.1…Safety
Standard for Flexible Cord and
Fixture Wire
2. U.L. 514B, Safety Standard for
Outlet Boxes and Fittings
3. CEC Section 4…Conductors
4.010…Uses of Flexible Cord
4.038…Uses of Portable Power Cable
12-010 (4)…Flexible Cords in Ducts
and Plenum Chambers
22-108 (2)…Bonding conductor for
Flexible Cords for Portable Equipment
44-350 (1) (b)…Flexible Cords for
Portable Stage Equipment
50-016…Flexible Cord for Attachment
Plugs and Similar Wiring Devices
70-108…Power Supply Cord-Factory-
Built Relocatable Structures and Non-
relocatable Structures
76-002…Temporary Wiring
76-010…Feeders
78-058 (2)…Marinas and Yacht
Clubs
78-104 (2)…Marine Wharves,
Structures, and Fishing Harbourgs
4. CSA C22.2 No. 49…Safety
Standards for Flexible Cords and
Cables and Fixture Wires
5. CSA C22.2 No. 18…Safety
Standards for Outlet Boxes, Conduit
Boxes and Fittings
Following is a brief description of
the three cords.
CONFITMRO_EN_ALL.pdf 60 11/28/2011 11:05:27 AM
61
T&B Conduit Fittings
Flexible Cord and Cable Fittings
Suggested Specifications for Flexible Cord and Cable Fittings
Flexible cord or cable and
associated fittings shall be suitable
for conditions of use and location
and approved for the purpose by
a nationally recognized testing
laboratory, inspection agency or
product evaluation organization.
Flexible cord or cable shall be so
connected to the device or fitting that
tension will not be transmitted to
joints or terminal screws. Sufficient
slack shall be provided to avoid
sharp flexing and straining. Cord or
cable shall be installed in such a
manner that liquid will tend to run off
the surface instead of draining
towards the fitting.
Where flexible cord or cable exposed
to intermittent or constant moisture
and subjected to mechanical strain is
terminated into a threaded or
threadless opening, terminating
fittings shall be of watertight strain
relief type such as Thomas & Betts
series 2920, 2920AL, 2920NM,
2520, 2631 or 2672. Fittings shall be
equipped with a beveled moisture
resistant/oil resistant synthetic rubber
bushing.
Where space is limited inside the
enclosure, a female hub type fitting
such as Thomas & Betts series 2631
shall be furnished. A captive resilient
sealing ‘O’ ring shall be included to
positively protect against damage
from overtorquing.
2520 and 2530 Series
Liquidtight Flexible
Cord & Cable Fittings
2920NM Series
Nonmetallic Liquidtight
Flexible Cord & Cable Fittings
The Ranger™ Series
2920AL Series
Aluminum Liquidtight
Flexible Cord & Cable Fittings
The Ranger™ Series
2920S Series
Steel Liquidtight
Flexible Cord & Cable Fittings
The Ranger™ Series
2631 Series
Liquidtight Flexible
Cord & Cable Fittings
2672 Series
Flexible Cord Fittings
(Plastic)
2920SST Series
Stainless Steel Liquidtight
Flexible Cord & Cable Fittings
TCF Series
Aluminum Tray/Cord Fitting
CONFITMRO_EN_ALL.pdf 61 11/28/2011 11:05:27 AM
62
T&B Conduit Fittings
Flexible Cord and Cable Fittings
Suggested Specifications for Flexible Cord and Cable Fittings—continued
Where flexible cord or cable exposed
to moisture is terminated into a
threadless opening using male threaded
hub type fittings such as Thomas &
Betts series 2520 or 2920, a suitable
moisture resistant/oil resistant
synthetic rubber gasket such as
Thomas & Betts series 5262 shall be
provided between the outside of box
or enclosure and fitting shoulder.
Resilient gasket shall be adequately
protected by and permanently
bonded to a metallic retainer.
Where exposed to environmental
conditions that are more than normally
corrosive, watertight strain relief
fittings shall be of high impact
thermoplastic construction such
as Thomas & Betts series 2672 or
2920NM.
Where flexible cord or cable passes
through either factory or field
punched, cut or drilled holes in metal
members, the cord or cable shall be
protected by thermoplastic bushing
such as Thomas & Betts series 3210,
3300. Bushing shall be firmly secured
in opening. Nylon bushed metallic
fittings such as Thomas & Betts
series 1942 may be substituted as
required.
For wet location, fittings furnished
with synthetic rubber bushing such
as Thomas & Betts series 2530 or
2672 shall be installed.
Series 3300
Nonmetallic Sheathed
Cable & Flexible Cord
Fitting
Series 1942
Insulated Nipple
Series 3210
Knockout Bushings
Series 5262
Sealing Gasket
CONFITMRO_EN_ALL.pdf 62 11/28/2011 11:05:28 AM
63
T&B Conduit Fittings
Flexible Cord and Cable Fittings
Cat. No. Hub Diameter SV, SVO, SVT, SVTO
Straight 90° Size Range Cord Sizes
2671 2680 3/8 .125-.275 18-2, 18-3
Cat. No. Hub Diameter S, SO, ST, STO SJO, SJT, SJTO, SJ
Straight 90° Size Range Cord Sizes Cord Sizes
2920NM 4960NM 1/2 .125-.375 18-2, 18-3* 18-2, 18-3, 18-4, 16-2,
2930NM 4970NM 3/4 16-3, 16-4*, 14-2, 14-3*
2921NM 4961NM 1/2 18-3, 18-4, 18-5, 18-6, 18-7*
2931NM 4971NM 3/4 .310-.560 18-3, 18-4*, 18-5, 16-2* 16-3, 16-4, 16-5, 16-6*, 14-2,
2940NM 1 14-3, 14-4, 12-2, 12-3, 12-4, 10-2
2922NM 1/2 16-5, 16-6, 14-2, 14-3, 14-4,
2932NM 4972NM 3/4 .500-.750 14-5, 12-2, 12-3, 12-4, 12-5, 12-4, 10-2, 10-3, 10-4
2941NM 1 10-2, 10-3, 10-4, 8-2
2942NM 1 .700-.950 10-4, 10-5, 8-3, 8-4
2688 1 .560-.690 14-3*, 14-4, 14-5*, 12-2, 12-3, 10-2*, 10-3, 10-4
12-4*, 10-2, 10-3*
2685 1 .660-.780 14-5, 12-4*, 12-5, 10-3*, 10-4 10-4
2696 3/4 .770-.895 10-5, 8-2, 8-3*
2686 1
2678 2687 1 .870-1.020 8-3*, 8-4*
2699 1 .890-1.090 8-4, 8-5*, 6-2, 6-3*, 6-4*, 4-2*
2702 — 1-1/4
2703 1-1/4 4-2*, 4-3, 2-2*
2704 1-1/4 1.270-1.470 4-4, 2-2*
2705 1-1/2 .890-1.150 8-4, 8-5, 6-2, 6-3, 6-4*, 4-2*
2706 1-1/2 1.140-1.400 6-5, 6-4*, 4-2*, 4-3, 4-4*,
2-2, 2-3*
2707 1-1/2 1.390-1.650 4-4*, 2-3*, 2-4
2708 2 1.190-1.530 6-5, 4-2*, 4-3, 4-4, 2-2, 2-3,
2-4*
2709 2 1.520-1.860 2-4*
2710 2 1.850-2.190
* Actual cord diameter must be determined before proper fitting can be selected.
Measure cord, if available, or refer to cord manufacturer’s catalogue.
How to Select T&B Flexible Cord Fittings
Step 1.
Determine Diameter Range in chart by using
cord size and type or by measuring the
diameter of your cord.
Step 2.
Determine catalogue number by choosing the
hub size and type (straight or 90°) for the
diameter range determined by step 1.
This chart can be used as a guide for selecting
the proper fitting for the U.L. Listed and CSA
Certified cords. Cords vary in sizes and cord
diameter should be measured whenever
possible.
CONFITMRO_EN_ALL.pdf 63 11/28/2011 11:05:28 AM
64
T&B Conduit Fittings
Flexible Cord and Cable Fittings
Flexible Cord and Power Cable Chart
AWG Size of Number of Conductors and Approximate O.D. (in.)
Type of Cord Conductors 2 Conductor 3 Conductor 4 Conductor
SV, SVO, SVT 18 .250 .260
SJ, SJO, 18 .300 .330 .360
SJT, SJTO 16 .330 .360 .390
14 .375 .395 .420
S, SO, ST, 18 .385 .400 .430
STO, and 16 .400 .425 .480
Portable 14 .530 .560 .605
Power Cables 12 .600 .635 .665
10 .640 .690 .745
8 .700-.840 .750-.910 .820-.990
6 .820-.930 .885-1.010 .975-1.100
4 1.080 1.170 1.270
3 1.170 1.240 1.340
2 1.270 1.340 1.480
1 1.440 1.510 1.680
1/0 1.520 1.650 1.790
2/0 1.650 1.750 1.930
3/0 1.770 1.890 2.070
4/0 1.920 2.070 2.260
250 2.160 2.390
14 — .410
12 — .450
10 — .530
Bus Drop 8 — .670
Cables 6 — .850
4 — .950
2 — 1.000
Note: The above dimensions are approximate and may vary depending upon the
manufacturer.
CONFITMRO_EN_ALL.pdf 64 11/28/2011 11:05:28 AM
65
T&B Conduit Fittings
Flexible Cord and cable Fittings
2520 Series
2520 Series
2631 Series
Specifications Liquidtight Flexible Cord and Cable Fittings
Gland
Retaining
Ring
Bushing
Body
Sealing
Gasket
(E)
(D)
(A)
(B)
Application
A liquidtight fittings to connect
flexible cord or power cable to
a box or enclosure and provide
adequate strain relief.
Features
Liquidtight connection with box
or enclosure is assured by:
(1) Taper threaded hub on
2520 series for female hub
application (A).
(2) Using sealing ring series 5262 with
2520 series for knockout
application (B).
(3) Captivated sealing ‘O’ ring on
2631 series (C).
Neoprene bushing makes liquidtight
installation; applies pressure against
cable the full length of bushing (D).
Thermoplastic or stainless steel
retaining ring (E).
(1) Will not abrade cord/cable jacket.
(2) Reduces installing torque effort.
U.L. Listed for liquidtightness, strain
relief and as an outlet bushing; CSA
certified watertight.
Standard Material
Gland, Body Steel/Malleable
Iron/Zinc Die Cast
Retaining Ring Thermoplastic/
Stainless Steel
Bushing Neoprene
‘O’ Ring Buna N
Standard Finish
Electro Zinc Plated & Chromate
Coated
Range
2520 Series, straight
0.125” outside diameter to 3.200”
outside diameter Cord or Cable
2200 Series, 45°
0.125” outside diameter to 1.485”
outside diameter Cord or Cable
2267 Series, 90°
0.125” outsidediameter to 1.875”
outside diameter Cord or Cable
Cord/Cable Type S, SO, SV, ST,
STO, SJ, SJO, SJT, SJTO, SVO & SVT
Conformity
U.L. 514B
CSA C22.2 No. 18.3
NFPA 70-2008 (ANSI)
2631 Series
Gland
Retaining
Ring
Bushing
Body
Nipple
(E)
(D)
(C)
CONFITMRO_EN_ALL.pdf 65 11/28/2011 11:05:28 AM
66
T&B Conduit Fittings
Flexible Cord and Cable Fittings
Fig. 1
Throat Dia.
Fig. 2
Throat Dia.
Liquidtight Strain Relief Fittings
Cable Size Throat
Range Hub Dia. Dimensions (in.)
Cat. No. min.-max. Size (min.) Fig. A B C
2516(.060-.125) 1/4” 23/64” 2 53/64 1-7/16 15/32
2517(.120-.250) 1/4” 23/64” 2 53/64 1-7/16 15/32
2518(.060-.150) 3/8” 29/64” 2 31/32 1-1/2 15/32
2519** (.150-.300) 3/8” 29/64” 2 31/32 1-1/2 15/32
2520 (.125-.250) 1/2” 9/16” 1 1-5/32 1-11/16 5/8
2521 (.250-.375) 1/2” 9/16” 1 1-5/32 1-11/16 5/8
2522 (.375-.500) 1/2” 9/16” 1 1-5/32 1-11/16 5/8
2523 (.450-.560) 1/2” 9/16” 1 1-5/32 1-11/16 5/8
2524* (.500-.625) 1/2” 5/8” 1 1-3/8 1-3/4 5/8
2525* (.625-.750) 1/2” 5/8” 1 1-3/8 1-3/4 5/8
2530 (.125-.250) 3/4” 13/16” 1 1-3/8 1-3/4 9/16
2531 (.250-.375) 3/4” 13/16” 1 1-3/8 1-3/4 9/16
2532 (.375-.500) 3/4” 13/16” 1 1-3/8 1-3/4 9/16
2534 (.500-.625) 3/4” 13/16” 1 1-3/8 1-3/4 9/16
2535 (.625-.750) 3/4” 13/16” 1 1-3/8 1-3/4 9/16
2536* (.750-.880) 3/4” 3/4” 1 1-11/161-15/16 5/8
2541 (.250-.375) 1” 49/64” 1 1-3/8 1-23/32 9/16
2542 (.375-.500) 1” 49/64” 1 1-3/8 1-23/32 9/16
2544 (.500-.625) 1” 49/64” 1 1-3/8 1-23/32 9/16
2545 (.625-.750) 1” 49/64” 1 1-3/8 1-23/32 9/16
2546 (.750-.875) 1” 63/64” 1 1-11/16 1-7/8 23/32
2547 (.875-.985) 1” 63/64” 1 1-11/16 1-7/8 9/16
2548* (.880-1.065) 1” 29/32” 1 2-3/32 2-3/8 25/32
2549* (1.065-1.205) 1” 29/32” 1 2-3/32 2-3/8 25/32
2558 (.880-1.065) 1-1/4” 1-17/64” 1 2-3/32 2-5/32 13/16
2559 (1.065-1.205) 1-1/4” 1-17/64” 1 2-3/32 2-5/32 13/16
2556* (1.187-1.375) 1-1/4” 1-1/4” 1 2-11/32 2-1/2 13/16
2557* (1.375-1.485) 1-1/4” 1-1/4” 1 2-11/32 2-1/2 13/16
2562 (.812-1.000) 1-1/2” 1-7/16” 1 2-11/32 2-1/2 11/16
2563 (1.000-1.187) 1-1/2” 1-7/16” 1 2-11/32 2-7/16 11/16
2564 (1.187-1.375) 1-1/2” 1-7/16” 1 2-11/32 2-7/16 11/16
2565* (1.375-1.625) 1-1/2” 1-29/64” 1 2-13/16 2-5/8 13/16
2573 (1.125-1.375) 2” 1-7/8” 1 2-13/16 2-5/8 13/16
2574 (1.375-1.625) 2” 1-7/8” 1 2-13/16 2-5/8 11/16
2575 (1.625-1.875) 2” 1-7/8” 1 2-13/16 2-5/8 11/16
2576* (1.750-1.965) 2” 1-29/32” 1 3-7/32 3-1/2 27/32
2577* (1.937-2.187) 2” 1-29/32” 1 3-7/32 3-1/2 27/32
2584 (1.750-1.965) 2-1/2” 2” 1 3-7/32 3-3/4 1-1/32
2585* (1.937-2.187) 2-1/2” 2” 1 3-7/32 3-3/4 1-1/32
2586* (2.156-2.360) 2-1/2” 2-5/32” 1 3-15/16 4-1/4 1-1/32
2587* (2.350-2.565) 2-1/2” 2-5/32” 1 3-15/16 4-1/4 1-1/32
2592 (2.156-2.360) 3” 2-13/32” 1 3-15/16 4-1/4 1-1/32
2593 (2.350-2.565) 3” 2-13/32” 1 3-15/16 4-1/4 1-1/32
2594 (2.535-2.750) 3” 2-13/32” 1 3-15/16 4-1/4 1-1/32
2595* (2.735-2.985) 3” 2-13/16” 1 4-11/164-13/16 1-1/8
2596* (2.970-3.220) 3” 2-13/16” 1 4-11/164-13/16 1-1/8
* Remove sufficient outer covering of cable to permit conductors to pass thru fitting body.
U.L. not applicable.
** Not CSA Certified.
Complies with JIC standards.
U.L. Listed as liquidtight strain relief, and outlet bushing. CSA certified watertight when used
with 5262 Series Sealing Ring. Gasket (Sold separately).
Temperature rating: 105°C.
For Wiremesh Grips refer to page 80.
5262 Series
Sealing Ring Gasket
sold separately
CONFITMRO_EN_ALL.pdf 66 11/28/2011 11:05:28 AM
67
T&B Conduit Fittings
Flexible Cord and Cable Fittings
Swing Radius
90° with neoprene bushings, tapered hub
threads, malleable iron.
Strain Relief Fittings
Cable Size Hub Dimensions (in.) Throat
Cat. No. min.-max. Size A B C Dia.
2267 (.125-.250) 1/2” 1-5/32 1-23/32 5/8 19/32
2268 (.250-.375) 1/2” 1-5/32 1-23/32 5/8 19/32
2269 (.375-.500) 1/2” 1-5/32 1-23/32 5/8 19/32
2270 (.450-.560) 1/2” 1-5/32 1-23/32 5/8 19/32
2250* (.500-.625) 1/2” 1-3/8 1-11/16 9/16 39/64
2251* (.625-.750) 1/2” 1-3/8 1-11/16 9/16 39/64
2252 (.125-.250) 3/4” 1-3/8 1-3/4 41/64 25/32
2271 (.250-.375) 3/4” 1-3/8 1-5/8 41/64 25/32
2272 (.375-.500) 3/4” 1-3/8 1-5/8 41/64 25/32
2273 (.500-.625) 3/4” 1-3/8 1-5/8 41/64 25/32
2274* (.620-.750) 3/4” 1-3/8 1-5/8 41/64 25/32
2253* (.750-.880) 3/4” 1-11/16 1-31/32 9/16 25/32
2254 (.375-.500) 1” 1-3/8 2 13/16 1
2255 (.500-.625) 1” 1-3/8 2 13/16 1
2256* (.625-.750) 1” 1-3/8 2 13/16 1
2275 (.750-.875) 1” 1-11/16 2 13/16 1
2276 (.875-.985) 1” 1-11/16 2 13/16 1
2257* (.880-1.065) 1” 2-3/32 2-21/32 25/32 15/16
2258* (1.065-1.205) 1” 2-3/32 2-21/32 25/32 15/16
2277 (.880-1.065) 1-1/4” 2-3/32 2-7/8 27/32 1-5/16
2278 (1.065-1.205) 1-1/4” 2-3/32 2-7/8 27/32 1-5/16
2279* (1.187-1.375) 1-1/4” 2-11/32 2-13/16 13/16 1-11/32
2280* (1.375-1.485) 1-1/4” 2-11/32 2-13/16 13/16 1-11/32
2281 (.812-1.000) 1-1/2” 2-11/32 2-7/8 13/16 1-15/32
2282 (1.000-1.187) 1-1/2” 2-11/32 2-7/8 13/16 1-15/32
2283* (1.187-1.375) 1-1/2” 2-11/32 2-7/8 13/16 1-15/32
2284 (1.125-1.375) 2” 2-13/16 3-1/4 27/32 1-31/32
2285 (1.375-1.625) 2” 2-13/16 3-1/4 27/32 1-31/32
2286 (1.625-1.875) 2” 2-13/16 3-1/4 27/32 1-31/32
* Remove sufficient outer covering of cable to permit conductors to pass through
fitting body.
Complies with J.I.C. standards and Federal Specs W-F-406B, W-F-408B.
Meets Coast Guard CG293
For Wiremesh Grips refer to page 80.
CONFITMRO_EN_ALL.pdf 67 11/28/2011 11:05:28 AM
68
T&B Conduit Fittings
Flexible Cord and Cable Fittings
Strain Relief Fittings
Cable Size Hub Dimensions (in.) Throat
Cat. No. min.-max. Size A B C Dia.
2200 (.125-.250) 1/2” 1-5/32 1-9/32 9/16 37/64
2201 (.250-.375) 1/2” 1-5/32 1-9/32 9/16 37/64
2202 (.375-.500) 1/2” 1-5/32 1-9/32 9/16 37/64
2203 (.450-.560) 1/2” 1-5/32 1-9/32 9/16 37/64
2204* (.500-.625) 1/2” 1-3/8 1-13/32 9/16 37/64
2205* (.625-.750) 1/2” 1-3/8 1-13/32 9/16 37/64
2206-TB (.125-.250) 3/4” 1-3/8 1-13/32 5/8 25/32
2207-TB (.250-.375) 3/4” 1-3/8 1-13/32 5/8 25/32
2208-TB (.375-.500) 3/4” 1-3/8 1-13/32 5/8 25/32
2209 (.500-.625) 3/4” 1-3/8 1-13/32 5/8 25/32
2210 (.625-.750) 3/4” 1-3/8 1-13/32 5/8 25/32
2211* (.750-.880) 3/4” 1-11/16 1-1/2 1-1/2 3/4
2213 (.375-.500) 1” 1-3/8 1-1/2 25/32 15/16
2214 (.500-.625) 1” 1-3/8 1-1/2 25/32 15/16
2215 (.625-.750) 1” 1-3/8 1-1/2 25/32 15/16
2216 (.750-.875) 1” 1-11/16 1-15/32 25/32 15/16
2217* (.875-.985) 1” 1-11/16 1-15/32 25/32 15/16
2218* (.880-1.065) 1” 2-3/32 1-31/32 25/32 15/16
2219* (1.065-1.205) 1” 2-3/32 1-31/32 25/32 15/16
2220-TB* (.880-1.065) 1-1/4” 2-3/32 1-29/32 13/16 1-5/16
2221* (1.065-1.205) 1-1/4” 2-3/32 1-29/32 13/16 1-5/16
2222* (1.187-1.375) 1-1/4” 2-11/32 2-1/4 13/16 1-21/64
2223* (1.375-1.485) 1-1/4” 2-11/32 2-1/4 13/16 1-21/64
* Remove sufficient outer covering of cable to permit conductors to pass through
fitting body.
U.L. Listed as liquidtight strain relief, and outlet bushing.
CSA certified watertight.
For Wiremesh Grips refer to page 80.
Swing Radius
45° with neoprene bushings, tapered hub
threads, malleable iron.
CONFITMRO_EN_ALL.pdf 68 11/28/2011 11:05:29 AM
69
T&B Conduit Fittings
Flexible Cord and Cable fittings
CHASE®Liquidtight Cord Fittings
Cable Size Range Hub Throat Dimensions (in.)
Cat. No. min.-max. Size Diam. A B
2631 (.125-.250) 1/2” 9/16” 1-1/16 1-5/8
2632 (.250-.375) 1/2” 9/16” 1-1/16 1-5/8
2633 (.375-.500) 1/2” 9/16” 1-1/16 1-5/8
2634 (.450-.560) 1/2” 9/16” 1-1/16 1-5/8
2637 (.125-.250) 3/4” 25/32” 1-3/8 1-3/16
2638 (.250-.375) 3/4” 25/32” 1-3/8 1-3/16
2639 (.375-.500) 3/4” 25/32” 1-3/8 1-3/16
2640 (.500-.625) 3/4” 25/32” 1-3/8 1-3/16
2641 (.625-.750) 3/4” 25/32” 1-3/8 1-3/16
CSA certified watertight.U.L. Listed as liquidtight strain relief, and outlet bushing.
Temperature Rating: 105°C.
Chase Liquidtight Cord Fittings are ideal for installation where space is limited inside
the enclosure.
Multi-Hole Cord Grip
Hub No. of Cord Dimensions (in.)
Cat. No. Size Diam. Diam. A B C
2520-2 1/2” 2 .220 1.125 1.687 .625
2530-2 3/4” 2 .220 1.375 1.750 .625
2531-2 3/4” 2 .260 1.375 1.750 .625
2531-3 3/4” 3 .260 1.375 1.750 .625
2541-2* 1” 2 .300 1.625 1.718 .781
2542-2* 1” 2 .375 1.625 1.718 .781
2540-3 1” 3 .225 1.625 1.718 .781
2541-3 1” 3 .300 1.625 1.718 .781
2540-4 1” 4 .220 1.625 1.718 .781
2555-2 1-1/4” 2 .500 2.093 2.375 .812
Range of cord diameter ±.010”.
In many applications you have only room for one fitting but you need to run two cables, for
example, proximity switches. Now you can provide strain relief and liquidtight protection with
T&B’s new multi-hole liquidtight strain relief fittings. With the ever increasing number of signal
cables, now you have a solution to the problem of how to strain relieve multiple cables in one
fitting.
*UL Listed only
Temperature Rating: 105°C.
A
C
B
CONFITMRO_EN_ALL.pdf 69 11/28/2011 11:05:29 AM
70
T&B Conduit Fittings
Flexible Cord and Cable Fittings
The Ranger®Series Liquidtight Strain Relief Fittings
Standard Material/Finish
2920S Series
4920 Series 2920NM Series 2920AL Series
4960 Series 4960NM Series 4960AL Series
Body Steel (ST) Nylon Aluminum (ST)
45° & 90° (Weather Stabilized) Malleable Iron (90°)
(Malleable Iron)
Gland Steel Nylon Aluminum
(Weather Stabilized)
Grip Plastic Nylon Aluminum
(Weather Stabilized)
Bushing Santoprene Oil Resistant Aluminum
Elastomer
Liquidtight Strain Relief Fittings—Straight
Hub Throat Cord Range Dimensions (in.)
Cat. No. Size Dia. min.-max. A B C
2920S 1/2 9/16 .125-.375 1-1/8 1-3/4 5/8
2921S 1/2 9/16 .310-.560 1-1/8 1-3/4 5/8
2922S* 1/2 9/16 .500-.750 1-3/8 1-3/4 5/8
2930S 3/4 13/16 .125-.375 1-3/8 1-25/32 3/4
2931S 3/4 13/16 .310-.560 1-3/8 1-25/32 3/4
2932S 3/4 13/16 .500-.750 1-3/8 1-25/32 3/4
2940S 1 1-1/16 .310-.560 1-3/8 1-3/4 1-3/16
2941S 1 1-1/16 .500-.750 1-3/8 1-3/4 1-3/16
2942S 1 31/32 .700-.950 1-5/8 1-7/8 1-3/16
*It may be necessary to remove sufficient outer covering of cable to permit conducters to
pass through the fitting body.
The only fitting to take a .250 inch
cable range.
New materials and computer aided
designs helped T&B develop a strain
relief fitting that will take twice the cable
range of ordinary strain relief fittings.
Features
Extended range with superior strain
relief.
Reduced overall size, fits into tighter
spaces.
Gland nut designed to restrict cable
bending.
Application
A liquidtight fitting to secure flexible cord
or power cable to a box or enclosure
and provide strain relief.
Range
Series Hub Size
.125” thru .950” 2920S 1/2 thru 1”
4920 1/2 thru 1”
4960 1/2 thru 1”
2920AL 1/2 thru 1”
4960AL 1/2 thru 1”
2920NM 1/2 thru 1”
.125 thru .750” 4960NM 1/2 thru 3/4”
Cat. No. Hub
Size
Throat
Dia.
Color Range
min.-max.
Dimensions (in.)
A B M
2920 1/2 9/16 .125-.375 1-1/8 1-3/4 5/8
2921 1/2 9/16 .310-.560 1-1/8 1-3/4 5/8
2922 1/2 9/16 .500-.750 1-3/8 1-3/4 5/8
2930 3/4 13/16 .125-.375 1-3/8 1-25/32 3/4
2931 3/4 13/16 .310-.560 1-3/8 1-25/32 3/4
2932 3/4 13/16 .500-.750 1-3/8 1-25/32 3/4
2940 11-1/16 .310-.560 1-3/8 1-3/4 1-3/16
2941 11-1/16 .500-.750 1-3/8 1-3/4 1-3/16
2942 131/32 .700-.950 1-5/8 1-7/8 1-3/16
Liquidtight Strain Relief Fittings
A
B
C
A
B
C
70-E.pdf 1 1/17/2012 10:05:40 AM
71
T&B Conduit Fittings
Flexible Cord and Cable Fittings
The Ranger®Series
Liquidtight Strain Relief Fittings—45° Angle
Hub Throat Dimensions (in.)
Cat. No. Size Dia. Cord Range A B C
4920 1/2 37/64 .125-.375 1-1/8 1-5/16 9/16
4921 1/2 37/64 .310-.560 1-1/8 1-5/16 9/16
4922 1/2 37/64 .500-.750 1-3/8 1-7/16 9/16
4932 3/4 25/32 .500-.750 1-3/8 1-7/16 5/8
4933 3/4 25/32 .700-.950 1-5/8 1-17/32 1-1/2
Liquidtight Strain Relief Fittings—90° Angle
Cat. Hub Throat Dimensions (in.)
No. Size Dia. Cord Range A B C
4960 1/2 19/32 .125-.375 1-1/8 1-3/4 5/8
4961 1/2 19/32 .310-.560 1-1/8 1-3/4 5/8
4962 1/2 19/32 .500-.750 1-3/8 1-24/64 5/8
4970 3/4 25/32 .125-.375 1-3/8 1-25/32 11/16
4971 3/4 25/32 .310-.560 1-3/8 1-25/32 11/16
4972 3/4 25/32 .500-.750 1-3/8 1-25/32 11/16
Swing Radius
CONFITMRO_EN_ALL.pdf 71 11/28/2011 11:05:29 AM
Aluminum Liquidtight Strain Relief Fittings—
Straight
Hub Throat Dimensions (in.)
Cat. No. Size Diam. Cord Range A B C
2920AL 1/2 9/16 .125-.375 1-1/8 1-3/4 5/8
2921AL 1/2 9/16 .310-.560 1-1/8 1-3/4 5/8
2922AL* 1/2 9/16 .500-.750 1-5/16 1-3/4 5/8
2930AL 3/4 13/16 .125-.375 1-5/16 1-25/32 3/8
2931AL 3/4 13/16 .310-.560 1-5/16 1-25/32 3/4
2932AL 3/4 13/16 .500-.750 1-5/16 1-25/32 3/4
2940AL 1 1-1/16 .310-.560 1-5/16 1-3/4 1-1/16
2941AL 1 1-1/16 .500-.750 1-5/16 1-3/4 1-1/16
2942AL 1 31/32 .700-.950 1-9/16 1-7/8 31/32
* It may be necessary to remove sufficient outer covering of cable to permit conductors
to pass through fitting body.
Aluminum Liquidtight Strain Relief Fittings—
90° Elbow
Trade or Throat Dimensions (in.)
Cat. No. Hub Size Diam. Cord Range A B C D
4960AL 1/2 9/16 .125-.375 1-1/8 1-3/4 5/8 1-5/16
4961AL 1/2 9/16 .360-.560 1-1/8 1-3/4 5/8 1-5/16
4962AL* 1/2 9/16 .500-.750 1-5/16 1-23/64 5/8 1-3/8
4970AL 3/4 25/32 .125-.375 1-5/16 1-25/32 11/16 1-15/32
4971AL 3/4 25/32 .310-.560 1-5/16 1-25/32 11/16 1-15/32
4972AL 3/4 25/32 .500-.750 1-5/16 1-25/32 11/16 1-15/32
4980AL 1 15/16 .310-.560 1-5/16 2-1/32 13/16 1-3/4
4981AL 1 15/16 .500-.750 1-5/16 2-1/32 13/16 1-3/4
4982AL 1 15/16 .700-.950 1-9/16 2-11/16 13/16 2
* It may be necessary to remove sufficient outer covering of cable to permit conductors to
pass through fitting body.
72
T&B Conduit Fittings
Flexible Cord and Cable Fittings
Body: malleable iron
Gland Nut: aluminum
Body and gland nut are aluminum.
Across
Corners
CONFITMRO_EN_ALL.pdf 72 11/28/2011 11:05:29 AM
T&B Conduit Fittings
T&B Ranger®Stainless Steel Liquidtight Cord Fittings
Food Processing
Pharmaceutical
Processing Pulp & Paper Mills
Wastewater Treatment Saltwater Applications Petrochemical Refining
Beveled Rubber Bushing Ensures
Superior Compression and
Sealing
Type 304 Stainless Steel Construction for Your Harshest Environments!
Until now, there has been no ideal solution for liquidtight connections of portable
cord to a box or enclosure in corrosive environments. Steel fittings rust and non-
metallic fittings cannot withstand high temperatures or ultraviolet exposure.
In response to customer demand, Thomas & Betts has developed the latest addition
to its high-performance line of T&B Ranger®Cord Fittings. Made of Type 304
stainless steel, T&B Ranger®Stainless Steel Liquidtight Cord Fittings stand up to
highly corrosive environments – such as washdown areas in food and beverage or
pharmaceutical processing – as well as high temperatures and UV exposure.
Like all T&B Ranger®Liquidtight Cord Fittings, the new stainless steel fittings offer
twice the cord diameter range of similar fittings, so you can do more with fewer sizes
to order and stock. They form a non-slip mechanical grip, providing a liquidtight seal
and the strain relief required for flexible portable cord connections.
Each fitting covers a 0.25” cord diameter
range – twice that of ordinary strain relief
fittings
Superior corrosion resistance in washdown
areas and other corrosive environments
Stands up to heat and UV exposure better
than non-metallic fittings
Beveled, moisture and oil resistant synthetic
rubber bushing system ensures superior
compression and sealing of fitting to cord
Bushing marked with cord range for easy
Identification out of box
2920 Series steel/malleable iron in straight, 45º and 90º
2920AL Series aluminum in straight and 90º
2920NM Series non-metallic in straight and 90º
Also available in other materials to meet all your cord-fitting needs!
T&B Stainless Steel Cord Fittings – 1/4” - 3/8” Hub Sizes
Catalogue
Number
Hub
Size (in.)
Cord Dia.
Range (in.)
Dimensions (in.)
A B C
2918SST 1/4 0.118 - 0.256 1.000 0.250 0.625
2919SST 3/8 0.157 - 0.315 1.313 0.438 0.750
73
T&B Stainless Steel Cord Fittings – 1/2” - 1” Hub Sizes
Catalogue
Number
Hub
Size (in.)
Cord Dia.
Range (in.)
Dimensions (in.)
A B C
2920SST 1/2 0.125 - 0.375 1.935 0.610 1.125
2921SST 1/2 0.310 – 0.560 1.935 0.610 1.125
2922SST 1/2 0.500 – 0.750 2.003 0.610 1.125
2930SST 3/4 0.125 – 0.375 2.063 0.630 1.125
2931SST 3/4 0.310 – 0.560 2.063 0.630 1.125
2932SST 3/4 0.500 – 0.750 2.063 0.630 1.125
2940SST 10.310 – 0.560 2.178 0.785 1.500
2941SST 10.500 – 0.750 2.218 0.785 1.500
2942SST 10.700 – 0.950 2.218 0.785 1.500
CONFITMRO_EN_ALL.pdf 73 11/28/2011 11:05:29 AM
74
T&B Conduit Fittings
Stainless Steel Liquidtight Conduit Connectors
Liquidtight Conduit Connectors
Cat. Dimensions Std. Pkg. UPC
Number Size A B C Qty. Number
Straight
5331SST *3/8" 1.360" 1.02" 25 78621097764
5332SST 1/2" 1.360" 1.18" 25 78621084482
5333SST 3/4" 1.388" 1.37" 25 78621074480
5334SST 1" 1.562" 1.77" 5 78621096334
5335SST 11/4" 1.720" 2.12" 20 78621097765
5336SST 11/2" 2.020" 2.48" 5 78621097766
5337SST 2" 2.335" 3.04" 2 78621097767
45oAngled
5341SST *3/8" 1.84" 1.02" 1.43" 25 78621097775
5342SST 1/2" 1.62" 1.18" 2.04" 25 78621097776
5343SST 3/4" 2.32" 1.37" 1.93" 10 78621097777
5344SST 1" 2.86" 1.77" 2.37" 5 78621097778
5345SST 11/4" 3.33" 2.12" 2.80" 5 78621097779
5346SST 11/2" 3.94" 2.48" 3.39" 2 78621097780
5347SST 2" 4.73" 3.04" 4.23" 1 78621097781
Cat. Dimensions Std. Pkg. UPC
Number Size A B C Qty. Number
90oAngled
5351SST *3/8" 1.95" 1.02" 1.84" 25 78621097768
5352SST 1/2" 2.12" 1.18" 2.07" 25 78621097769
5353SST 3/4" 2.47" 1.37" 2.44" 10 78621097770
5354SST 1" 2.98" 1.77" 2.90" 5 78621097771
5355SST 11/4" 3.53" 2.12" 3.36" 5 78621097772
5356SST 11/2" 4.16" 2.48" 3.88" 2 78621097773
5357SST 2" 8.60" 3.04" 4.69" 1 78621097774
Sealing Gasket
5261 3/8" 50 78621005261
5262 1/2" 50 78621005262
5263 3/4" 25 78621005263
5264 1" 25 78621005264
5265 11/4" 5 78621005265
5266 11/2" 5 78621005266
5267 2" 5 78621005267
The Strength of Steel — with Superior
Corrosion-Resistance!
Until now, there’s been no ideal conduit fitting solution for use in
heavily corrosive environments. Traditional metallic fittings corrode
and require frequent replacement. Non-metallic fittings offer less
strength, lower UV-resistance, and don’t stand up well in extreme
temperatures.
T&B Stainless Steel Liquidtight Conduit Connectors are constructed
of 304 stainless steel to resist corrosion while offering high strength,
high UV-resistance, and high endurance. Choose among a full range
of fittings in straight, 45o, and 90oangled configurations for 3/8" to 2"
conduit sizes. Look for the distinctive blue insulator and sealing ring
for assurance of T&B quality.
Ideal for industrial MRO and OEM applications in food and
beverage, pharmaceutical, petrochemical, waste water, salt water,
and other corrosive environments
Connects metallic-cored liquidtight conduit to a box
or enclosure
304 stainless steel body and gland-nut resists corrosion far better
than other metallic fittings
Stronger, more UV-resistant than nonmetallic fittings
Available in straight, 45o, and 90oangled configurations to fit
conduit from 3/8" to 2"
UL®Listed Ratings: 3, 3R, 4, 4X
5262 Sealing Ring Gasket (sold separately) includes a stainless
steel retaining ring to prevent elongation of the gasket and is made
from Santoprenematerial, ensuring a superior seal
5262 Series
Sealing Ring Gasket
sold separately
A
B
A
BC
A
BC
Locknut not included
*
3/8” conduit fitting has 3/8” hub
CONFITMRO_EN_ALL.pdf 74 11/28/2011 11:05:31 AM
75
T&B Conduit Fittings
Flexible Cord and Cable Fittings
The Ranger®Series Nylon Cord Grip Fitting
A T&B “RANGER” Exclusive
Smaller shape: 30% smaller envelope
Wide range: twice the cable range
Reduced size means fittings can be placed closer together.
Wider range means one fitting can cover twice the cable range of others.
Nonmetallic means corrosion resistance.
Nonmetallic Liquidtight Strain Relief Fitting—Straight
Trade or Throat Dimensions (in.)
Cat. No. Hub Size Diam. Cord Range A B C
2920NM 1/2” 9/16 .125-.375 1-7/32 2-1/8 5/8
2921NM 1/2” 9/16 .310-.560 1-7/32 2-1/8 5/8
2922NM 1/2” 9/16 .500-.750 1-13/32 2-5/32 5/8
2930NM 3/4” 3/4 .125-.375 1-13/32 2-3/16 5/8
2931NM 3/4” 3/4 .310-.560 1-13/32 2-3/16 5/8
2932NM 3/4” 3/4 .500-.750 1-13/32 2-3/16 5/8
2940NM 1” 29/32 .310-.560 1-13/32 2-11/32 25/32
2941NM 1” 29/32 .500-.750 1-13/32 2-11/32 25/32
2942NM 1” 29/32 .700-.950 1-43/64 2-3/8 25/32
Nonmetallic Liquidtight Strain Relief fitting—
90° Elbow
Trade or Throat Dimensions (in.)
Cat. No. Hub Size Diam. Cord Range A B C
4960NM 1/2” 9/16 .125-.375 1-7/32 1-1/4 5/8
4961NM 1/2” 9/16 .310-.560 1-7/32 1-1/4 5/8
4970NM 3/4” 3/4 .125-.375 1-13/32 1-3/8 5/8
4971NM 3/4” 3/4 .310-.560 1-13/32 1-3/8 5/8
4972NM 3/4” 3/4 .500-.750 1-13/32 1-3/8 5/8
• Weather Stabilized Nylon
• U.L. 94-V2
• Temperature Rating: -34ÞC to +105ÞC
• Meets Coast Guard CG293
• New Reduced Size
• Smaller Footprint
90° elbow, new reduced size, smaller footprint.
• Weather Stabilized Nylon
• U.L. 94-V2
• Temperature Rating: -34ÞC to +105ÞC
• Meets Coast Guard CG293
CONFITMRO_EN_ALL.pdf 75 11/28/2011 11:05:31 AM
76
T&B Conduit Fittings
Flexible Cord and Cable Fittings
Large Tapered Bushing
High-Performance Chuck Grip
Tray Cable Applications
Portable Cord Applications
One heck of a grip!
Increased Safety
for Hazardous Locations
Introducing the Silver GripTray-Cord Fitting- the safe,
yet cost-efficient choice for increased safety when terminating
portable cord and tray cable in hazardous locations.
Designed for use in Class I, Gas and Vapour environments,
the Silver GripTray-Cord Fittingprovides efficient strain relief
for cables entering enclosures and raceways, and for
cords used on portable equipment.
Corrosion-resistant, non-magnetic
aluminum construction
Tapered neoprene bushing and O-ring
seal out moisture and dirt ingress
Chuck grip provides high mechanical
pull-out performance. Exceeds
applicable requirements.
Hand-tightens — no tools required
Now available in 316 stainless steel
• 90°C temperature rating
C US
Silver Grip—TCF
Series Tray-Cord Fitting
76-e.pdf 1 6/1/2012 4:04:35 PM
77
T&B Conduit Fittings
Tray Cable
Complies with IEC requirements for Class I, Zone 2 locations when used with enclosures containing no
arcing or sparking devices. For enclosures with arcing or sparking devices, TCF®fittings must be
used in combination with a certified Class I hazardous location sealing fitting.
Portable Cord
Complies with IEC requirements for Class I, Zone 1 locations when used with enclosures containing no
arcing or sparking devices. For enclosures with arcing or sparking devices, TCF®fittings must be used
in combination with a certified Class I hazardous location sealing fitting.
* When cord will not fit through body, strip cord jacket and trim fillers if required. Insert cable ensuring the outer jacket reaches the end
of the bushing as shown. Tighten gland nut onto body.
Ordering Information
Applications
File Number LR4484, Certificate Number 1388229
CSA Class 4418-05 Fittings for Hazardous Locations Class I, Zone 1 Ex e II, IP66; Type 4/4X, (CSA)
• CSAus Class 4418-85 Fittings for Hazardous Locations Class I, Zone 1, A Ex e II, IP66; Type 4/4X, (CSAus)
N.B.: Tray cable is not suitable for use in Zone 1 locations.
Portable cord can be used in Zone 1 applications only when installed on portable equipment.
TCF ®Series — Tray / Cord Fitting
O-Ring
Body
Bushing
Chuck
Grip
Maximum
Opening
Gland
Nut
For stainless steel (316), replace AL for SS6 (up to 1“ only)
®
Utilisation
For use with unarmored cable Types suitable for use in Class I, Zone 1 (e.g.) Extra Hard Usage Cord)
Series TCF Cable Glands, when used with Tray Cables are suitable to be installed in Class I, Zone 2/Div. 2
Classified Hazardous Locations Areas according to CEC/NEC Wiring Method, or subject to Local Inspection
Authority having jurisdiction.
Hub
Size
NPT
Catalogue
Number
Throat
Diameter
(in.)
Minimum
Cable Dia.
(in.)
Maximum
Opening
(in.)
1/2 TCF050-27AL 0.330 0.150 0.270
1/2 TCF050-40AL 0.540 0.250 0.400
1/2 TCF050-54AL 0.540 0.400 0.540
1/2 TCF050-67AL 0.540* 0.540 0.670
1/2 TCF050-78AL 0.540* 0.660 0.780
3/4 TCF075-40AL 0.540 0.250 0.400
3/4 TCF075-54AL 0.540 0.400 0.540
3/4 TCF075-67AL 0.780 0.540 0.670
3/4 TCF075-78AL 0.780 0.660 0.780
3/4 TCF075-88AL 0.765* 0.770 0.880
1TCF100-78AL 0.980 0.660 0.780
1TCF100-88AL 0.980 0.770 0.880
1TCF100-100AL 0.980* 0.870 1.000
1TCF100-109AL 0.980 0.940 1.090
1-1/4 TCF125-109AL 1.255 0.890 1.090
1-1/4 TCF125-128AL 1.255* 1.080 1.280
1-1/4 TCF125-147AL 1.255* 1.270 1.470
1-1/2 TCF150-115AL 1.470 0.890 1.150
1-1/2 TCF150-140AL 1.470 1.140 1.400
1-1/2 TCF150-165AL 1.470* 1.390 1.650
2TCF200-153AL 1.896 1.190 1.530
2TCF200-186AL 1.896 1.520 1.860
2TCF200-219AL 2.062* 1.850 2.190
2-1/2 TCF250-252AL 2.466* 2.120 2.520
3TCF300-278AL 2.780 2.380 2.780
3TCF300-304AL 3.050 2.640 3.040
3TCF300-330AL 3.068* 2.900 3.300
CONFITMRO_EN_ALL.pdf 77 11/28/2011 11:05:32 AM
78
T&B Conduit Fittings
Flexible Cord and Cable Fittings
The Canadian Electrical Code states
that tray cable in hazardous locations
can be used either within the cable
tray, or outside the tray - provided
there is additional protection. The
TrayStar TM fitting was designed and
engineered for either application and
comes complete with the bushing,
ground cone and sealing ring for
different product applications.
Ease of Installation
Installation is quick and easy. When
used on metallic liquidtight conduit, the
fitting hub size correlates with that of
the conduit trade size. (i.e. 1/2” fitting
accomodates 1/2” conduit). The
bushings, when utilized, are designed
to accomodate a broad range of tray
cable diameters. Either liquid or putty
sealing compound can be used for a
positive, gastight seal. The compound
is ordered separately to allow for
flexibility in making the correct
selection for various types of
installations. The sealing compounds
cure in just a few hours. The
TrayStar TM fitting also has disconnect
capability: the cable can be
disconnected and reconnected after
being sealed.
The unique hexagonal gland nut is
conveniently grooved for screwdriver
installation in extremely cramped areas.
The gland nut is also clearly identified
with the catalogue number and CSA
approvals. It is also anodized an aqua-
blue colour to identify it as a
Hazardous Location, Tray Cable Fitting.
Superior Construction
TrayStar TM fittings have a low-profile
compact design and are made of
copper-free aluminum for long-lasting
trouble-free service. Fittings are
precision machined for superior fit and
ease of installation.
Inside Tray Used with a neoprene bushing,
TrayStar TM terminates tray cable within the tray
itself.
Sealing
compound
Hub
A
B
C
Bushing
Retainer
With conduit
C
A
B
Double
face tape
Sealing
compound
Ground
cone
Sealing
ring
Gland
nut
Putty insert
Body
SC4-KIT
SC65
For more details, refer to the
installation/Instruction sheet.
With bushing
Note - Thomas & Betts hazardous locations fittings with integral seals (STX, STEX, HLT and TC series) are UL and CSA certified only when used
with SC4-KIT or SC65 sealing compounds. No other sealing compounds have been tested, certified or listed.
Cat. No. Description Volume (cubic centimeter)
SC65 Putty type sealing compound (cut-to-length stick)
34
cc
Cat. No. Description Volume (cubic centimeter)
SC4-KIT Liquid type sealing compound (includes pouch of sealing
compound with integral spout, fiber and damming material).
66
cc
Use SC4-KIT liquid compound for shielded cables.
Sealing Compounds
U.L. File No. E-82038
CSA File No. LR-23086
Suitable for use on cables with a maximum of four conductors (including ground).
We do not recommend SC65 for use with shielded cables.
Quantity of compound required will vary according to cable conductor fill.
Outside Tray tray cable must be protected
within conduit and flexible liquidtight metallic
conduit. In this case, the connector bushing is
simply replaced with a ground cone/sealing
ring to terminate the assembly.
Silver Grip®— Liquidtight Fittings for Tray Cable
Approx Compound
Required*
Range Over Conduit Putty / Liquid A B C
Hub Size Jacket (in.) Trade Size SC65/SC4-KIT Throat Dia. Overall Dim.
Cat. No. N.P.T. min. max. (in.) cc (in.) (in.) (in.)
HLT050DATA 1/2 0.250 0.310 1/2 7 0.505 1.870 1.625
HLT050 1/2 0.300 0.400 1/2 7 0.505 1.870 1.625
HLT075 3/4 0.320 0.570 3/4 15 0.707 2.140 2.075
HLT100 1 0.400 0.750 1 23 0.932 2.270 2.290
HLT125 1-1/4 0.625 1.000 1-1/4 45 1.263 2.750 2.840
HLT150 1-1/2 0.780 1.200 1-1/2 68 1.493 3.000 3.275
HLT200 2 1.000 1.560 2 112 1.950 3.200 3.640
4-250TC 2-1/2 1.700 2.200 2-1/2 175 2.250 3.800 4.000
4-300TC 3 2.150 2.700 3 359 2.750 3.860 4.690
4-350TC 3-1/2 2.650 3.230 3-1/2 536 3.280 4.100 5.220
4-400TC 4 3.180 3.790 4 690 3.840 4.000 5.630
† Not UL Listed
* Sealing compound not included with HLT-series. Order separately.
SC65 putty supplied with each TC-series fitting. SC4-Kit liquid sealing compound not approved for use with TC-series.
TC-series is suitable for use with tray cable only and cannot be used with conduit.
Materials
Aluminum: The above listed catalogue numbers relate to aluminum fittings.
Steel: HLT-series is also available in steel. Add the suffix "S" to the catalogue number (example HLT050S).
Certifications
Type HLA. CSA Certified Class I, Division 2, Groups A, B, C and D; Class II, Division 2, Groups E, F and G; Class III,
Division 2, Enclosure Type 4 SL (integral seal). CSA File 23086.
CONFITMRO_EN_ALL.pdf 78 11/28/2011 11:05:32 AM
79
T&B Conduit Fittings
Flexible Cord and Cable Fittings
Nonmetallic Liquidtight Strain
Relief Fitting—Straight
Trade or Throat Dimensions (in.)
Cat. No. Hub Size Diam. Cord Range A B C
2671 3/8” 0.33 .125-.275 2 29/32 15/32
2690 1/2” 0.33 .125-.275 2-4/16 29/32 19/32
2672 1/2” 0.55 .250-.400 2-19/32 19/32 19/32
2673* 1/2” 0.55 .400-.560 2-19/32 19/32 19/32
2691* 1/2” 0.54 .560-.690 3 1-9/10 19/32
2692* 1/2” 0.54 .660-.780 3 1-9/16 19/32
2693 3/4” 0.55 .250-.400 2-11/16 1-9/32 5/8
2694* 3/4” 0.55 .400-.560 2-11/16 1-9/32 5/8
2674 3/4” 0.79 .560-.690 3 1-9/16 5/8
2675 3/4” 0.79 .660-.780 3 1-9/16 5/8
2696* 3/4” 0.76 .770-.895 3-3/16 1-7/8 5/8
2676 1” 0.98 .660-.780 3-5/16 1-7/8 25/32
2677 1” 0.98 .770-.895 3-5/10 1-7/8 25/32
2678* 1” 0.98 .870-1.020 3-5/10 1-7/8 25/32
2699 1” 0.98 .890-1.090 3-3/10 2-19/32 25/32
2702 1-1/4” 1.25 .890-1.090 3-5/16 1-7/8 25/32
2703 1-1/4” 1.25 1.080-1.280 4 2-19/32 13/16
2704 1-1/4” 1.25 1.270-1.470 4 2-19/32 13/16
2705TB 1-1/2” 1.47 .890-1.150 4-3/16 2-31/32 13/16
2706 1-1/2” 1.47 1.140-1.400 4-5/16 2-31/32 13/16
2707 1-1/2” 1.47 1.390-1.650 4-5/16 2-31/32 13/16
2708 2” 1.89 1.190-1.530 5-3/32 3-1/2 27/32
2709 2” 1.89 1.520-1.860 4-29/32 3-1/2 27/32
2710* 2” 1.89 1.850-2.190 4-29/32 3-1/2 27/32
* Remove sufficient outer covering of cable to permit conductors to pass thru fitting body.
Nonmetallic Liquidtight Strain Relief Fitting—
90° Elbow
Trade or Throat Dimensions (in.)
Cat. No. Hub Size Diam. Cord Range A B C
2680 3/8” .33 .125-.275 .90 1.8 .460
2681 1/2” .55 .250-.400 1.27 2.5 .610
2682* 1/2” .55 .400-.560 1.27 2.5 .610
2683 3/4” .78 .560-.690 1.57 2.8 .610
2684 3/4” .78 .660-.780 1.57 2.8 .610
2688 1” .98 .560-.690 1.89 3.0 .770
2685 1” .98 .660-.780 1.89 3.2 .770
2686 1” .98 .770-.895 1.89 3.2 .770
2687* 1” .98 .870-1.020 1.89 3.2 .770
* Remove sufficient outer covering of cable to permit conductors to pass thru fitting body. 90°
angle, standard size body.
• Weather Stabilized Nylon
• U.L. 94-V2
• Temperature Rating: -34ÞC to +105ÞC
• Meets Coast Guard CG293
90° angle, standard size body.
• Weather Stabilized Nylon
• U.L. 94-V2
• Temperature Rating: -34ÞC to +105ÞC
• Meets Coast Guard CG293
CONFITMRO_EN_ALL.pdf 79 11/28/2011 11:05:33 AM
80
T&B Conduit Fittings
Portable Cord and Cable Fittings
Strain Relief Fitting
Straight 45° 90°
Cat. Grip Ranger™ Ranger™ T&B Ranger™ T&B Ranger™ Ranger™ T&B
No. Range Steel Aluminum Steel
Malleable Iron
Steel
Malleable Iron
Aluminum Steel
WMG-PC1 .187-.250 2920S 2920AL 2520 4920 2200 4960 4960AL 2267
WMG-PC2 .250-.375 2920S 2920AL 2521 4920 2201 4960 4960AL 2268
WMG-PC3 .375-.500 2921S 2921AL 2522 4921 2202 4961 4961AL 2269
2922S 2922AL 2524 4922 2204 4962 4962AL 2250
WMG-PC4 .500-.625 2932S 2932AL 2534 4932 2209 4972 4972AL 2273
2941S 2941AL 2544 4941 2214 4981 4981AL 2255
2922S 2922AL 2525 4922 2205 4962 4962AL 2251
WMG-PC5 .625-.750 2932S 2932AL 2535 4932 2210 4972 4972AL 2274
2941S 2941AL 2545 4941 2215 4981 4981AL 2256
WMG-PC6 .187-.250 2930S 2930AL 2530 4930 2206 4970 4970AL 2252
WMG-PC7 .250-.375 2930S 2930AL 2531 4930 2207 4970 4970AL 2271
2541
WMG-PC8 .375-.500 2931S 2931AL 2532 4931 2208 4961 4961AL 2272
2940S 2940AL 2542 4940 2213 4980 4980AL 2254
WMG-PC9 .750-.875 2536 2211 2253
2942S 2942AL 2546 4942 2216 4982 4982AL 2275
WMG-PC10 .875-1.000 2547 2217 2276
WMG-PC11 .875-1.000 2548 2218 2257
2558 2220 2277
2548 2218 2257
WMG-PC12 1.000-1.125 2558 2220 2277
2549 2219 2258
2559 2221 2278
WMG-PC13 1.125-1.250 2549 2258 2258 2219
2559 2221 2278
2556 2279 2279 2222
WMG-PC14 1.125-1.250 2563 – 2282
2564 – 2283
WMG-PC15 1.250-1.375 2256 2222 2279
2564 — 2283
WMG-PC16* 1.375-1.500 2557 2223 2280
WMG-PC17* 1.125-1.250 2573 – 2284
2920 Series 2920AL Series
2516 Series
Wiremesh grips support the following Liquidtight
Cord Fittings Series.
Wiremesh Grips for Portable Cord
Application
• Provides high gripping strength for
adequate cable support and strain relief
without damage to the cable sheath
• Compression of a tapered neoprene
bushing, assures the watertight integrity of
the fittings
Cord and Cable Type
• S, SO, SV, ST, STD, SJ, SJO, SJT, SJTO,
SVD
Features
• Prevents severe cord bends and pullouts
• Used in aluminum and/or steel fittings
Material
Wiremesh made of stainless steel. Retaining
rings made of aluminum.
Environment Classification
• Ordinary Locations
Range
.187 – 3.220
How to select proper wiremesh grip:
1. Determine O.D. of portable cord e.g. .200
2. Determine size of knockout or threaded
hub e.g. 1/2"
3. Select Cat. No. of strain relief fitting
e.g. 2520, 2920AL.
4. Match up O.D. with grip range and strain
relief to determine Cat. No. of Wiremesh
Grip (e.g. .200 + 2520 = WMP-PC1)
WMG-PC Series Wiremesh Grips for Portable Cord
T&B Wiremesh grips are ordered separately and fit with your existing inventory of
Ranger™ fittings and liquidtight strain relief fittings. There’s no need to duplicate
inventory.
Strain Relief Fitting
Straight 90°
Cat. Grip T&B T&B
No. Range Steel Steel
WMG-PC18* 1.250-1.375 2573 2284
WMG-PC19* 1.375-1.500 2565 2285
2574
WMG-PC20* 1.500-1.625 2565 2285
2574
WMG-PC21* 1.625-1.750 2575 2286
WMG-PC22* 1.750-1.875 2575 2286
*Replacement Gland Nut Supplied With These
Catalogue Numbers only
CONFITMRO_EN_ALL.pdf 80 11/28/2011 11:05:33 AM
81
T&B Conduit Fittings
Portable Cord and Cable Fittings
Nonmetallic Cable Glands
Hub Cable Range Length of Thread USE T&B Unit Std. UPC
Cat no. Size Colour in. mm in. mm Locknut cat. no. pkg. pkg. code
NPT Threads
CC-NPT38-B 3/8 BLACK .197 - .394 5-10 0.590 15 CI-1703PL* 50 250 786210-95582
CC-NPT38-G 3/8 GREY .197 - .394 5-10 0.590 15 CI-1703PL* 50 250 786210-07817
CC-NPT12-B 1/2” BLACK .394 - .551 10-14 0.590 15 LN501 50 250 786210-95583
CC-NPT12-G 1/2” GREY .394 - .551 10-14 0.590 15 LN501 50 250 786210-07824
CC-NPT34-B 3/4” BLACK .512 - .709 13-18 0.590 15 LN502 25 100 786210-95584
CC-NPT34-G 3/4” GREY .512 - .709 13-18 0.590 15 LN502 25 100 786210-07853
CC-NPT1-B 1” BLACK .709 - .984 18-25 0.709 18 LN503 20 100 786210-95586
CC-NPT1-G 1” GREY .709 - .984 18-25 0.709 18 LN503 20 100 786210-14682
ISO/Metric Threads
CC-ISO-16-G M16 GREY .197 - .394 5-10 0.394 10 LN-ISO16-G 50 250 786210-21170
CC-ISO-20-G M20 GREY .236 - .473 6-12 0.590 15 LN-ISO20-G 50 250 786210-21173
CC-ISO-25-G M25 GREY .512 - .709 13-18 0.590 15 LN-ISO25-G 25 250 786210-21174
CC-ISO-32-G M32 GREY .709 - .984 18-25 0.590 15 LN-ISO32-G 20 250 786210-21175
CC-ISO-40-G M40 GREY .748 - 1.10 22-32 0.709 18
PG Threads
CC-PG7-G 7 GREY .118 - .256 3-6.5 0.315 8 LN-PG7-G 50 200 786210-21160
CC-PG9-G 9 GREY .157 - .315 4-8 0.315 8 LN-PG9-G 50 200 786210-21162
CC-PG11-G 11 GREY .197 - .394 5-10 0.315 8 LN-PG11-G 25 100 786210-21163
CC-PG135-G 13-1/2 GREY .236 - .473 6-12 0.354 9 LN-PG135-G 25 100 786210-21164
CC-PG16-G 16 GREY .394 - .551 10-14 0.394 10 LN-PG16-G 25 100 786210-21165
CC-PG21-G 21 GREY .512 - .709 13-18 0.433 11 LN-PG21-G 10 50 786210-21166
CC-PG29-G 29 GREY .709 - .984 18-25 0.433 11 LN-PG29-G 10 50 786210-21167
CC-PG36-G 36 GREY .867 - 1.26 22-32 0.512 13 LN-PG36-G 10 50 786210-21168
Nonmetallic Cable Glands Low Profile for Tight Spots
T&B Nylon Cable Glands have a sturdy cable sealing mechanism which results in
superior strain relief. The compact size ensures quick and easy installation in
cramped spaces. The nonmetallic construction provides excellent corrosion,
chemical and impact resistance. The glands have long threads and locknuts are
available.
• Halogen free
• Flame retardant material rated UL 94-V0
• Rated IP 68 5 BAR, suitable for NEMA 4 enclosures
• UL Listed, CSA listed for certain ranges of cable
• Working Temperatures: -30°C (-86°F) to +80°C (176°F) Continuous, 150°C
(276°F) Intermittent
• Meets VDE ratings
Sturdy Nylon 6 for strong, lightweight construction.
Gray colour shown, also available in black.
* Not CSA Certified.
81-E.pdf 1 6/18/2012 2:02:34 PM
82
T&B Conduit Fittings
Portable Cord and Cable Fittings
Metric PG-to-N.P.T. Thread Adapters
N.P.T. Thread
Cat. No. Thread (mating) (at housing)
PG11-38 3/8” PG11
PG16-50 1/2” PG16
PG21-75 3/4” PG21
PG29-100 1” PG29
PG29-125 1-1/4” PG29
PG36-125 1-1/4” PG36
PG36-150 1-1/2” PG36
Metric Two-Screw Clamp Fittings
Cable O.D. (in.) Thread
Cat. No. Min. Max. (at housing)
CC11-38 .400” .470” PG11
CC11-38P* .250” .325” PG11
CC135-50 .400” .535” PG13.5
CC16-50 .455” .625” PG16
CC21-75 .513” .815” PG21
CC29-100 .800” .175” PG291
CC36-125 1.050” .450” PG361
CC42-150 1.500” .800” PG421
* Plastic
Metric Cord Grip Fittings
Cable O.D. (in.) Thread
Cat. No. Min. Max. (at housing)
CG11-38 .200” .470” PG11
CG11-38P* .325” .340” PG11
CG135-50 .285” .545” PG13.5
CG16-50 .285” .625” PG16
CG21-75 .395” .790” PG21
CG29-100 .780” .060” PG291
CG36-125 .960” .375” PG361
CG42-150 1.630” .650” PG421
* Plastic
Conduit Entry Blind Plug
Thread
Cat. No. (at housing)
CXP722 PG13.5
CXP723 PG16
CXP724 PG21
CXP725 PG29
CXP726 PG36
CXP727 PG42
Supplied standard with all hoods and bases.
Special sizes/hood combinations available.
Style may vary depending on size.
Standard European style can be specified/
supplied with hoods and bases.
CONFITMRO_EN_ALL.pdf 82 11/28/2011 11:05:33 AM
83
T&B Conduit Fittings
Service Entrance Cable Fittings
Suggested Specifications for Service Entrance Fittings
Series 4175
Pipe Strap (EMT)
Series 1275/1275AL Pipe Strap
(Rigid Metal Conduit & I.M.C.)
Series 1350/1350AL Pipe Spacer
(Rigid Metal Conduit I.M.C. & EMT)
Series 3870
Bonding & Grounding Bushing—Insulated
Series 106
Bonding Locknut
All service fittings shall be approved for
the purpose by a nationally recognized
testing laboratory, inspection agency, or
product evaluation organization.
Where service raceway consists of a
rigid metal conduit, intermediate
metal conduit, electrical metallic
tubing or where service entrance
cable is used as service conductors a
suitable raintight service head
conforming to Federal Standard
W-C-586 shall be provided.
Service raceway shall be securely
fastened in place to the supporting
surface at intervals as specified by the
Code using suitable straps and
spacers; straps and spacers shall be of
malleable iron or steel construction, hot
dipped galvanized or electro zinc
plated conforming to Canadian
Standards Association Standard
C22.2 No. 18.4 and as manufactured
by Thomas & Betts: series 1275 or
4175 straps and series 1350 spacers;
aluminum straps or spacers such as
series 1275AL and series 1350AL
may be substituted when installed in
environmental conditions that are
more than normally corrosive.
For grounding and bonding of service
raceway, end of raceway or the
terminating fitting shall be equipped
with bonding locknuts and insulated
metallic grounding and bonding
bushing as required.
Bonding locknuts shall be of hardened
steel or malleable iron construction,
electro zinc plated, and provided with
hardened bonding screws as
manufactured by Thomas & Betts,
series 106 bonding locknuts.
Insulated metallic grounding and
bonding
bushing shall be of malleable
iron/steel construction, electro zinc
plated and assembled with an
insulator listed or certified for
150°C/302°F service as manufactured
by Thomas & Betts, series 3870.
CONFITMRO_EN_ALL.pdf 83 11/28/2011 11:05:33 AM
84
T&B Conduit Fittings
Service Entrance Cable Fittings
Where service entrance cable is used
as overhead service conductors and
code requires use of a service head,
entrance caps shall be installed; caps
shall be cast metal type of suitable
ferrous or non ferrous metal equipped
with thermoset insulators and proper
knockout openings; when installed
with proper drip loop, caps must
assure raintight conditions.
Terminating fittings for service entrance
cable (Type SE or USE) or underground
feeder and branch—circuit cable (Type
UF) in locations where exposed to
intermittent or constant moisture or in
dry locations and subjected to
mechanical strain shall be of watertight
strain relief type as manufactured by
Thomas & Betts, series 2111 or 2116;
fittings shall be constructed of ferrous
or non ferrous metal and equipped
with taper-threaded hub, beveled
moisture resistant/oil resistant
synthetic rubber bushing.
In dry locations, nylon insulated two
screw type fittings of malleable
iron/steel construction, electro zinc
plated inside and outside including
threads, such as series 3302M
manufactured by Thomas & Betts may
be substituted.
Where service entrance cable is
terminated into a threadless opening
using hub type fittings, a gasket shall
be provided between the outside of
box or enclosure and fitting shoulder;
gasket shall be of moisture resistant/ oil
resistant synthetic rubber type
adequately protected by and
permanently retained to a metallic
retainer as manufactured by Thomas &
Betts, series 5262 or 5302.
Service entrance cable shall be
adequately supported at intervals
enumerated in code using cable straps
conforming to requirements of CSA
Standard C22.2 No.18.4; cable straps
shall be of malleable iron/steel
construction, hot dipped galvanized or
electro zinc plated as manufactured by
Thomas & Betts, series 1341.
At the point where the service cable
enters the building, a suitable sill
plate shall be provided; sill/wall plate
shall be sealed to assure raintight
conditions.
Series 2111
Service Entrance Cable Fitting
Series 2116
Underground Feeder Cable Fitting
Series 3302M
Two Screw Fitting (Insulated)
Series 5262, 5302
Sealing Gasket
Series 1341
Cable Strap
Suggested Specifications for Service Entrance Fittings—continued
CONFITMRO_EN_ALL.pdf 84 11/28/2011 11:05:34 AM
85
T&B Conduit Fittings
Service Entrance Cable Fittings
Application
To connect service entrance cables
to a meter box or an enclosure.
Standard Material/Finish
Body Zinc Die Cast/As cast
Gland Steel/Electro Zinc
Plated & Chromate
Coated
Retaining Ring Stainless
Steel/Passivated
Bushing Neoprene/As molded
Range
Oval (Flat) Cable Size
0.260 x 0.500 thru 1.062 x 1.765
Type USE Cable Size
3 #12 thru 3-4/0 AWG Conductors
Hub Size
1¼2thru 2NPT (taper pipe threads)
Features
Neoprene bushing, resists oil and
water; grips cable the full length of
the bushing providing adequate
strain relief without damaging outer
jacket (A).
Taper-threaded body (B).
Stainless steel retaining ring protects
cable jacket against abrasion;
reduces installing torque effort (C).
Rugged ribbed steel gland
construction (D).
Suitable for Type USE I75, USE I90
and USE B90 (CEC Table 19) Service
Entrance Cable.
Listing/Certification
CEC Rule 6-300 (1) add (b) use
underground service entrance with
mechanical protection as per CEC
Rule 12-012
Conformity
U.L.514B, NEMA FB-1, Federal
Standard H-28 (Threads),
NFPA70-2009 (ANSI)
CSA C22.2 No. 18.3
Application
To connect underground feeder
cables to a box or an enclosure.
Standard Material/Finish
Body Zinc Die Cast/As cast
Gland Steel/Electro Zinc
Plated & Chromate
Coated
Retaining Ring Stainless Steel/
Passivated
Bushing Neoprene/As molded
Range
Oval (Flat) Cable Size
0.235 x 0.500 thru 0.260 x 0.740
Hub Size 1/2” thru 1” NPT (tapered
pipe threads)
Features
Neoprene bushing resists oil and
water; grips cable the full length of
the bushing providing adequate strain
relief without damaging outer jacket
(A).
Taper-threaded body (B).
Stainless steel retaining ring protects
cable jacket against abrasion;
reduces installing torque effort (C).
Rugged ribbed steel gland
construction (D).
Listing/Certification
CEC Rule 30-1004 (d) Wiring method,
underground, where deviation has
been allowed for permanent outdoor
floodlighting installation.
Conformity
U.L.514B, NEMA FB-1, Federal
Standard H-28 (Threads),
NFPA70-2009 (ANSI)
CSA C22.2 No. 18.3
Service Entrance Cable Fittings
(Type SE/Type Use)
2111 Series
2116 Series
Underground Feeder Cable Fittings
(C)
(D)
(D)
(C)
(B)
(A)
(B)
(A)
CONFITMRO_EN_ALL.pdf 85 11/28/2011 11:05:34 AM
86
T&B Conduit Fittings
Service Entrance Cable Fittings
Underground Liquidtight Feeder Cable Fittings
Dimensions (in.)
Hub Cable A B C D E F G H
Cat. No. Size Opening min. max. min. max
2116* 1/2” .235 x .500 1-11/16 5/8 1 .060 .235 .350 .500 9/16 1-1/8 1-1/8
2237 3/4” .230 x .430 1-9/16 9/16 1-7/32 .080 .230 .320 .430 13/16 1-3/8 1-3/8
2238 3/4” .235 x .465 1-9/16 9/16 1-7/32 .050 .235 .340 .465 13/16 1-3/8 1-3/8
2239 3/4” .240 x .685 1-9/16 9/16 1-7/32 .060 .240 .500 .685 13/16 1-3/8 1-3/8
* Not CSA Certified.
Watertight Fittings for Oval Cables
Hub Dimensions (in.) Oval Cable Range
Cat. No. Size A B C D E max. min.
2111 1/2” 1-3/4 1-1/4 5/8 1-3/8 1-3/8 .420 x .560 .380 x .520
2232 3/4” .385 x .600 .260 x .500
2233 3/4” 1-11/16 1-1/4 9/16 1-3/8 1-3/8 .500 x .750 .375 x .625
2234 3/4” .555 x .800 .490 x .675
2432 1” .385 x .600 .260 x .500
2433 1” 1-11/16 1-1/4 9/16 1-3/8 1-3/4 .500 x .750 .375 x .625
2434 1” .555 x .800 .430 x .675
2438 1” 1-3/4 1-1/2 25/32 1-11/16 1-3/4 .565 x .855 .440 x .730
2439 1” .635 x .975 .510 x .850
2442 1-1/4” .635 x .975 .510 x .850
2443 1-1/4” 2-1/16 1-15/16 5/8 2-1/16 2-1/8 .640 x 1.050 .490 x .900
2446 1-1/4” .750 x 1.150 .565 x .965
2454 1-1/2” 2-1/4 2-1/8 11/16 2-5/16 2-5/16 .840 x 1.275 .655 x 1.090
2447 1-1/2” .880 x 1.425 .695 x 1.240
2448 2” .968 x 1.500 .790 x 1.390
2449 2” 2-3/8 2-5/8 11/16 2-3/4 2-13/32 1.062 x 1.765 .850 x 1.550
2450 2” 1.820 x 1.190 1.700 x 1.050
Oil and water resistant neoprene bushing is
especially designed for sealing around
underground feeder cable. Stainless steel
retaining ring provides a bearing surface for the
glandnut and eliminates cable twist. Ribbed
glandnut is strong and easily tightened with a
wrench to make a connection of high strength.
A design with two tapers inside the body—a
slow one and a fast one—permits the stocking
of fewer fittings for varied cable sizes and
allows maximum take-up. The tapered neoprene
bushings are resistant to oil, sunlight, and water.
Hex gland and body take the same wrench
opening and a stainless steel slip ring prevents
cable from twisting as gland ring is being
tightened. Threads on the body are tapered for
watersealing.
CONFITMRO_EN_ALL.pdf 86 11/28/2011 11:05:34 AM
87
T&B Conduit Fittings
Service Entrance Cable Fittings
Cable Straps
Dimensions (in.)
Cat. No. Wire Size A B
1341 2-#10 5/8 1-1/8
1344 3-#6 or 3-#8 5/8 1-15/16
1345* 3-#4 or 3-#2 13/16 1-59/64
1346 3-1/0 3/4 2-7/16
1347 3-4/0 3/4 2-25/32
* Steel, hot dipped galvanized.
Nylon UF Cable Fittings for Corrosive Environments
Dimensions (in.)
Hub UF Cable Range A B C
Cat. No. Size max. min. max. ± .060 ± .060
2827 1/2” .550 x .280 .400 x .190 2.60 1.270 .600
2828 3/4” .675 x .280 .525 x .190 3.00 1.570 .620
2829 3/4” .775 x .280 .625 x .190 3.00 1.570 .620
• Tapered threaded hub.
• Liquidtight and dust-tight; hand tightens—
no tools required.
• Corrosive and weather resistant nylon for
outdoor and indoor applications.
Each strap takes a wide range of sizes because
of the rocking action of the foot. Hole is for 1¼4
screw. Malleable iron, hot dipped galvanized
construction.
CONFITMRO_EN_ALL.pdf 87 11/28/2011 11:05:34 AM
88
T&B Conduit Fittings
Liquidtight Flexible Metal Conduit Fittings
Please Note
The excerpts and other material herein, whether relating to the Canadian
Electrical Code 2009 Part I, the Underwriters Laboratories, Inc. listing,
to industry practice or otherwise, is not intended to provide all relevant
information required for use and installation. Reference to original or primary
source material and data is mandatory before any application or use is made of
the product.
Specifications Liquidtight Flexible Metal Conduit
Ref. CEC Rule 12-1300
Liquidtight flexible metal conduit is a
raceway of circular cross section having
an outer liquidtight nonmetallic, sunlight
resistant jacket over a flexible metal core.
Liquidtight flexible metal conduit is
permitted to be used for exposed or
concealed work, in dry, damp or wet
locations indoors and outdoors. With the
exception of Class I Division I locations,
liquidtight flexible metal conduit is
considered an acceptable wiring method
in
hazardous locations Class 1 Division 2
(CEC Rule J18-152(6).
Liquidtight flexible metal conduit is
not permitted where subjected to mecha-
nical injury. The conduit is not permitted to
be used underground or embedded in
cinder fill or concrete. It cannot be used as
a general purpose raceway.
Use of liquidtight conduit is not
permitted where any combination of
ambient or conductor temperature will
produce temperature in excess of that for
which the jacket is rated or in locations
where flexing at low temperature will
injure jacket. Liquidtight flexible metal
conduit is not permitted for conductors
over 600 volts.
Liquidtight flexible conduit is available in
3/8” through 6” trade size. Conduit is
constructed with galvanized steel or
aluminum core, regular or extra flex. Outer
jacket is available for a variety
of applications, e.g. oil resistant where
exposed to cutting oils and for service
temperature ranging from -50°C to
150°C.
Listed and certified conduits are
constructed of galvanized steel core
and thermoplastic jacket rated for
maximum service temperature of 60°C
and suitable for exposure to mineral oils
but not to gasoline and similar solvents.
Conduit is required to be supported
adequately, and bending is restricted to
360 degrees total.
Please refer to the following for further
details and complete information:
1. U.L. 360…Safety Standards for
Liquidtight Flexible Steel Conduit
2. U.L. 514, Safety Standards for
Outlet Boxes and Fittings
3. W-F-406…Federal Specification:
Fittings for Cable, Power, Electrical
and Conduit, Metal, Flexible
4. NEMA FB-1…Standards Publication:
Fittings and Supports for Conduit and
Cable Assemblies
5. EMP-1…JIC Electrical Standards
for Mass Production Equipment
6. EGP-1…JIC Electrical Standards for
General Purpose Machine Tools
7. CEC Section 12-1300…Wiring
Methods (Liquidtight Metal Conduit)
8. CSA C22.2 No. 56…Safety
Standard for Flexible Metallic
Conduit and Liquidtight Flexible
Metal Conduit
9. CSA C22.2 No. 18…Safety
Standards for Outlet Boxes,
Conduit Boxes and Fittings
CONFITMRO_EN_ALL.pdf 88 11/28/2011 11:05:34 AM
89
T&B Conduit Fittings
Liquidtight Flexible Metal Conduit Fittings
Suggested Specifications for Liquidtight Flexible Metal
Conduit Fittings
Liquidtight Flexible Metal conduit
used shall be of the type with
galvanized steel core inside and
outside and outer thermoplastic
jacket suitable for the ambient
environmental conditions. Jacket shall
be positively locked to core to
prevent sleeving. Where used as an
equipment grounding conductor, the
conduit shall conform to applicable
standards U.L. 360/CSA C22.2 No.
56.
Flexible conduit when installed shall
have sufficient slack to avoid sharp
flexing and straining due to vibration
and thermal expansion/constriction.
Conduit shall be installed in such a
manner that liquids will tend to run off
the surface instead of draining
toward the fittings.
Where liquidtight flexible metal
conduit terminates into a threaded
or threadless opening, the conduit
shall be assembled with approved
liquidtight fittings. Fittings used shall
be reusable type of malleable
iron/steel construction, electro-zinc
plated inside and outside, furnished
with nylon insulated throat and taper
threaded hub as manufactured by
Thomas & Betts, series 5331.
Approved fittings installed shall be:
(1) Designed to prevent sleeving,
assure plastic (raceway jacket)
to plastic (gasket) seal.
(2) Equipped with grounding device
to assure ground continuity
irrespective of raceway core
construction. Grounding device
if inserted into raceway and
directly in contact with conductors
shall have rolled over edges for
sizes under 5 inches.
At the point of flexing (i.e. where
raceway leaves fitting) the
thermoplastic raceway jacket shall
not be permitted to be in direct
contact with metal.
Where liquidtight flexible metal
conduit is terminated into a
threadless opening using a threaded
hub fitting such as Thomas & Betts
series 5331, a suitable moisture
resistant/oil resistant synthetic rubber
gasket such as Thomas & Betts
series 5262 shall be provided
between the outside of box or
enclosure and fitting shoulder. Gasket
shall be adequately protected by and
permanently bonded to a metallic
retainer.
Where liquidtight flexible metallic
raceway is installed in outdoor or
indoor locations and is exposed to
environmental conditions that are
more than normally corrosive to
exposed surfaces, PVC coated
liquidtight flexible metal conduit
fittings such as series 3321
manufactured by Thomas & Betts
shall be used. Fittings shall be coated
with a nominal thickness of .040 PVC
and must meet the general
requirements for liquidtight flexible
metal conduit fittings indicated
above.
Liquidtight fittings required to couple
threaded end of a fitting or pipe where
rotation of fitting or pipe is limited or
restricted shall be reusable type of
malleable iron/steel construction,
electro-zinc plated inside /outside with
taper threaded hub as manufactured by
Thomas & Betts, series 41. Fittings
shall be equipped with a moisture
resistant/oil resistant synthetic
rubber gasket. Metal to metal seal or
metal to thermoplastic seal for this
application shall be considered
unacceptable.
Series 5331; Series 5231AL
Liquidtight Flexible Metal
Conduit Fittings
Series 3321
PVC Coated Liquidtight Flexible
Metal Conduit Fittings
Series 41
Liquidtight Union
5331GR Series
External Bonding
Series 5262
Sealing Gasket
Stainless
Steel
Retainer
Resilient Seal
Resilient Sealing
Material Locked
in Steel Retainer
CONFITMRO_EN_ALL.pdf 89 11/28/2011 11:05:34 AM
90
T&B Conduit Fittings
Liquidtight Flexible Metal Conduit Fittings
Specifications
Application
Used where flexible metal raceway
is installed in outdoor or indoor
locations where exposed to
continuous or intermittent moisture.
To positively bond conduit to box
or enclosure.
Features
Ability to install quickly with low
torque effort.
•Ground cone design offers following
advantages:
(1) Compresses metallic convolutions;
provides high quality ground
contact with low impedance and
high raceway holding power (A).
(2) Single helical thread on ground
cone is easy to install without
cross threading; accepts
variations in raceway diameters
and convolution pitch (B).
(3) Rolled over edge protects
conductors (C).
Sealing ring design has following
exclusive features:
(1) Grips and seals at leading and
trailing edge—will not abrade
raceway jacket (D).
(2) Provided with grooves on inside
diameter for anti-sleeving (E).
(3) Shoulders on both ends for extra
sealing (F).
(4) Symmetrical shape assures
foolproof assembly.
Can be disconnected and reused
Watertight/oiltight installation at box or
enclosure termination is assured by:
(1) External taper thread hub on 5331
series and use of sealing gasket
5262 series (G).
(2) Captive sealing ‘O’ ring on 5361
series (H).
(3) Taper tapped hole on 5271series.
Suitable for use in Class I Division 2,
Class II Division 1 and 2 and Class III
Division 1 and 2 Hazardous Locations
per CEC Section 18.
Class I, Zone 2, CEC Rule 18-152 (6)
Class I, Div. 2, CEC Rule J18-152 (6)
Class II, Div. 1 CEC Rule 18-202 (4) (b)
Class II, Div. 2, CEC Rule 18-252 (4)
Class III, Div.1 CEC Rule 18-302 (4)
Class III, Div. 2 CEC Rule 18-352
CEC Rule 12-1306 stipulates “a
separate bonding conductor shall be
installed in liquidtight flexible conduit in
accordance with section 10”.
1/2” and 1-1/4” sizes Laboratory
tested to carry ground fault current of
up to 1000 amps RMS with duration
of fault current 3 cycles.
Conforms with JIC requirements.
Available with imperial, I.S.O. and PG
threaded hub.
Standard Material
5331-5361-5271 Series
Body, Gland, Locknut and Ground
Cones: All steel or malleable iron.
Sealing Ring and Insulator:
All thermoplastic rated min. -20ºc
max. 105°C
Sealing Gasket: Stainless Steel and
Buna N
5231 AL Series
All Copper-free Aluminum
(non-insulated)
Standard Finish
5331-5361-5271 Series
Electro Zinc Plated and Chromate
Coated
5231 AL Series
Copper-free Aluminum
Range
5331 Series 3/8” thru 6” conduit
5341 Series 3/8” thru 4” conduit
5351 Series 3/8” thru 4” conduit
5361 Series 3/8” thru 4” conduit
5271 Series 3/8” thru 1-1/4”
conduit
5231 AL Series 3/8” thru 4” conduit
All hubs provided with taper pipe
threads (NPT).
Conformity
U.L. 514B
CSA C22.2 No. 18.3
NEMA FB-1
NFPA 70-2008 (ANSI)
JIC EGP1, JIC EMP1
Federal Specification W-F-406
Federal standard H-28 (Threads)
5331 Series
5231 AL Series
5361 Series
Chase Style
5361 Series
5271 Series
5341 Series…
same as 5331, except 45° Fittings
5351 Series…
same as 5331, except 90° Fittings
Predetermined
Compression
CONFITMRO_EN_ALL.pdf 90 11/28/2011 11:05:35 AM
91
T&B Conduit Fittings
Liquidtight Flexible Metal Conduit Fittings
T&B HT-Series Liquidtight Fittings are available
straight, 45°, and 90°.
High Temperature Flexible Metal Liquidtight Fittings
Suggested Specification
Where Liquidtight flexible metal fittings are required in high temperature environments
up to 150°C:
Fitting’s body, gland, locknut and ground cone shall be constructed from steel or
malleable iron, electro-zinc plated and chromate coated for corrosion protection.
Fitting’s sealing ring and throat insulator will be molded from high temperature nylon
suitable for temperatures up to 150°C and a minimum UL flammability
rating of UL94-V2.
The fitting shall be constructed to accept high temperature flexible metal
liquidtight conduit rated to 150°C (works with our ATX Series conduit, p. 135).
The fitting shall have a plastic throat insulator to protect conductors.
The fitting shall have a steel ground cone to:
- provide high quality ground contact
-single helical thread for easy installation into conduit
-rolled over edge to protect conductors
The fitting shall have a plastic sealing ring to:
-grip and seal at leading and trailing edge (double bevel up to 2”) of conduit jacket
-provide a watertight/oiltight seal
The fittings shall be capable to terminate the conduit in either a threaded or
threadless opening.
For applications where termination into a threaded opening is required the
fitting shall have external tapered NPT threads.
For applications where termination into a threadless opening is required use an
acceptable sealing ring.
Fittings shall conform to UL 514B.
Accepted Manufacturers: Thomas & Betts 5331-HT straight series,
5341-HT 45° series, 5351-HT 90° series; 5262 sealing ring series.
Straight Liquidtight Fittings
Conduit Dimensions (in.)
Cat. No. Size (in.) A B C
5331-HT 3/8 1-5/32 1-1/2 9/16
5332-HT 1/2 1-3/8 1-9/16 9/16
5333-HT 3/4 1-21/32 1-5/8 9/16
5334-HT 1 1-7/8 2-1/16 3/4
5335-HT 1-1/4 2-9/32 2-1/2 13/16
5336-HT 1-1/2 2-22/32 2-11/16 13/16
5337-HT 2 3-1/4 3-1/16 7/8
5338-HT 2-1/2 3-3/4 4-1/8 1
5339-HT 3 4-1/2 4-1/4 1
5340-HT 4 5-1/2 4-1/2 1-1/8
45° Liquidtight Fittings
Conduit Dimensions (in.)
Cat. No. Size (in.) A B C
5341-HT 3/8 1-5/32 1-9/16 9/16
5342-HT 1/2 1-3/8 1-7/8 9/16
5343-HT 3/4 1-21/32 2-1/8 9/16
5344-HT 1 1-7/8 2-1/4 3/4
5345-HT 1-1/4 2-9/32 2-3/4 13/16
5346-HT 1-1/2 2-22/32 2-3/8 13/16
5347-HT 2 3-1/4 3-7/8 7/8
90° Liquidtight Fittings
Conduit Dimensions (in.)
Cat. No. Size (in.) A B C
5351-HT 3/8 1-5/32 1-3/8 9/16
5352-HT 1/2 1-3/8 1-9/16 9/16
5353-HT 3/4 1-21/32 1-3/4 9/16
5354-HT 1 1-7/8 2-3/16 3/4
5355-HT 1-1/4 2-9/32 2-3/4 13/16
5356-HT 1-1/2 2-22/322-15/16 13/16
5357-HT 2 3-1/4 3-7/16 7/8
B
A
C
B
A
C
B
A
C
Please note: There is no CSA and UL Standards applicable for High Temperature Fittings or Conduits.
Therefore neither HT Fittings nor HT Conduit bear these Certifications/Listings.
91-e.pdf 1 5/29/2012 9:24:15 AM
92
T&B Conduit Fittings
Liquidtight Flexible Metal Conduit Fittings
Liquidtight Flexible Metal Conduit Fittings
For Control and Power Cable Applications
Hub Conduit Dimensions (in.)
Cat. No. Size Size A B C
5229* 1/4” 1/4 27/32 1-3/8 15/32
5330* 3/8” 5/16 63/64 1-3/8 15/32
* U.L. and CSA not applicable.
Straight Fittings
Cat. No. Conduit Dimensions (in.)
Insulated AluminumNoninsulated Size A B C
5331**
5231AL 5231 3/8 1-5/32 1-1/2 9/16
5332
5232AL 5232 1/2 1-3/8 1-9/16 9/16
5333
5233AL 5233 3/4 1-21/32 1-5/8 9/16
5334
5234AL 5234 1 1-7/8 2-1/16 3/4
5335
5235AL 5235 1-1/4 29/32 2-1/2 13/16
5336+ 5236AL 5236 1-1/2 2-23/32 2-11/16 13/16
5337+ 5237AL 5237 2 3-1/4 3-1/16 7/8
5338+ 5238AL 5238 2-1/2 3-3/4 4-1/8 1
5339+ 5239AL 5239 3 4-1/2 4-1/4 1
5340+ 5240AL 5240 4 5-1/2 4-1/2 1-1/8
5385*+ 5285* 5 8-3/4 7 1-7/8
5386*+ 6 8-3/4 8-1/2 2
Suitable for hazardous locations use in CEC Rule 18-152 (6) Class I, Zone 2;
CEC Rule J18-152 (6) Class I, Division 2; CEC Rule 18-202 (4) Class II, Division 1;
CEC Rule 18-252 (4) Class II, Division 1
** 3/8” Conduit Fitting has 1/2” hub.
U.L. Listed liquidtight; and CSA Certified watertight.
For Dura-Plate™ finish, add prefix 040- to Cat. No. Consult Customer Service for details.
* Not CSA Certified.
Steel
+
Malleable Iron
45° Angle Fittings*
Cat. No. Conduit Dimensions (in.)
Insulated Noninsulated Size A B C
5341** 5241 3/8 1-5/32 1-9/16 9/16
5342 5242 1/2 1-3/8 1-7/8 9/16
5343 5243 3/4 1-21/32 2-1/8 9/16
5344 5244 1 1-7/8 2-1/4 3/4
5345 5245 1-1/4 29/32 2-3/4 1-3/16
5346 5246 1-1/2 2-23/32 3-3/8 1-3/16
5347 5247 2 3-1/4 3-7/8 7/8
5348 5248 2-1/2 3-3/4 4-1/4 1
5349 5249 3 4-1/2 4-1/4 1
5350 5250 4 5-1/2 4-5/8 1-1/8
* Suitable for hazardous locations use CEC Rule 18-152 (6) Class I, Zone 2;
CEC Rule J18-152 (6) Class I, Division 2; CEC Rule 18-202 (4) Class II, Division 1;
CEC Rule 18-252 (4) Class II, Division 1
** 3/8” Conduit Fitting has 1/2” hub.
U.L. Listed liquidtight; and CSA Certified watertight.
For Dura-Plate™ finish, add prefix 040- to Cat. No. Consult Customer Service for details.
For Wiremesh Grips refer to page 80.
Steel, malleable iron, or aluminum tapered hub
threads. With safe-edge ground thru 4” cone and
double bevel sealing ring (through 2”).
Malleable iron, tapered hub threads. With safe-
edge ground cone and double bevel sealing ring
(through 2”).
CONFITMRO_EN_ALL.pdf 92 11/28/2011 11:05:35 AM
93
T&B Conduit Fittings
Liquidtight Flexible Metal Conduit Fittings
90° Angle Fittings
Cat. No. Hub Conduit Dimensions (in.)
Insulated Noninsulated Aluminum Size Size A B C
5351 5251 5251AL 1/2” 3/8” 1-5/32 1-3/8 9/16
5352 5252 5252AL 1/2” 1/2” 1-3/8 1-9/16 9/16
5353 5253 5253AL 3/4” 3/4” 1-21/32 1-3/4 9/16
5354 5254 5254AL 1” 1” 1-7/8 2-3/16 3/4
5355 5255 5255AL 1-1/4” 1-1/4” 29/32 2-3/4 13/16
5356 5256 5256AL 1-1/2” 1-1/2” 2-23/32 2-15/16 13/16
5357 5257 5257AL 2” 2” 3-1/4 3-7/16 7/8
5358 5258 5258AL* 2-1/2” 2-1/2” 3-3/4 8-7/8 1
5359 5259 3” 3” 4-1/2 10-1/4 1
5360 5260 4” 4” 5-1/2 12-5/8 1-1/8
Suitable for hazardous locations use in CEC Rule 18-152 (6) Class I, Zone 2;
CEC Rule J18-152 (6) Class I, Division 2; CEC Rule 18-202 (4) Class II, Division 1;
CEC Rule 18-252 (4) Class II, Division 2.
U.L. Listed liquidtight; and CSA Certified watertight.
* Not CSA Certified.
Wiremesh Grips for Liquidtight Fittings
Conduit Liquidtight Fittings 90°
Cat. No. Size Straight 45° 90° Chase Chase Adapter
WMG-LT1 3/8” 5331 5341 5351 5361 5371 5271
WMG-LT2 1/2” 5332 5342 5352 5362 5372 5272
WMG-LT3 3/4” 5333 5343 5353 5363 5373 5273
WMG-LT4 1” 5334 5344 5354 5364 5374 5274
WMG-LT5 1-1/4” 5335 5345 5355 5365 5275
WMG-LT6 1-1/2” 5336 5346 5356 5366 5276
WMG-LT7 2” 5337 5347 5357 5367 5277
WMG-LT8 2-1/2” 5338 5348 5358 5368 5278
WMG-LT9 3” 5339 5349 5359 5369 5279
WMG-LT10 4” 5340 5350 5360 5370 5282
Order wiremesh grip separately: no need to duplicate inventory.
Prevents severe conduit bends and pullout.
CONFITMRO_EN_ALL.pdf 93 11/28/2011 11:05:35 AM
94
T&B Conduit Fittings
Liquidtight Flexible Metal Conduit Fittings
Liquidtight Adapter
To Connect Liquidtight to Threaded Rigid Conduit
Conduit Size Dimensions (in.) Std.
Cat. No. (in.) A B C Pkg.
5271 3/8 1-5/32 1-9/16 1-3/8 50
5272 1/2 1-3/8 1-11/16 1-3/8 50
5273 3/4 1-21/32 1-3/4 1-3/8 50
5274 1 1-7/8 2-1/8 1-3/8 25
5275 1-1/4 2-9/32 2-1/2 1-3/8 25
5276 1-1/2 2-3/4 2-11/16 1-3/8 10
With SAFE-EDGE™ ground cone and double bevel sealing ring (through 2”).
Suitable for hazardous locations use in CEC Rule 18-152 (6) Class I, Zone 2;
CEC Rule J18-152 (6) Class I, Division 2; CEC Rule 18-202 (4) Class II, Division 1;
CEC Rule 18-252 (4) Class II, Division 2.
Nylon Insulated CHASE®Fittings
Steel or Malleable Iron
Conduit Size Dimensions (in.) Std.
Cat. No. (in.) A B C Pkg.
5361 3/8 1-3/32 1-3/8 1/8 100
5362 1/2 1-3/8 1-3/8 3/16 100
5363 3/4 1-11/16 1-5/8 1/4 50
5364 1 2-1/32 2-1/16 1/4 25
5365 1-1/4 2-3/8 2-3/8 5/16 25
5366 1-1/2 2-15/16 2-3/4 3/8 10
5367 2 2-9/16 3 3/8 5
5368 2-1/2 4-3/8 3-15/16 7/16 5
5369 3 5-1/8 4-1/8 1/2 5
5370 4 5-1/8 4-3/8 1/2 5
With SAFE-EDGE™ ground cone and double bevel sealing ring (through 2”).
Note: UL Listed Liquidtight; and CSA Certified Watertight.
Suitable for hazardous locations use in CEC Rule 18-156 (6) Class I, Zone 2;
CEC Rule J18-156 (3) Class I, Division 2; CEC Rule 18-202 (4) Class II, Division 1;
CEC Rule 18-252 (4) Class II, Division 2.
B
B
C
C
A
A
CONFITMRO_EN_ALL.pdf 94 11/28/2011 11:05:36 AM
95
T&B Conduit Fittings
Liquidtight Flexible Metal Conduit Fittings
Specifications — External Bonding
Application
Used where external bonding jumper
is required around liquidtight flexible
metal conduit.
To positively bond conduit to box
or enclosure.
Used where flexible raceway is
installed in outdoor or indoor locations
where exposed to continuous or
intermittent moisture.
Features
Designed with provision to install
bonding jumper in several positions.
Designed to accept mechanical or
compression lug.
Ability to install quickly with low
torque effort.
(i) Compresses metallic
convolutions; assures ground
contact with low impedance and
high raceway holding power (A).
(ii) Single helical thread on ground
cone is easy to install without
cross threading; accepts
variations in raceway diameters
and
convolution pitch (B).
(iii) Rolled over edge protects
conductors (C).
Sealing ring design has following
exclusive features:
(i) Grips and seals at leading and
trailing edge—will not abrade
raceway jacket (D).
(ii) Provided with grooves on inside
diameter for anti-sleeving (E).
(iii) Shoulders on both ends for extra
sealing (F).
(iv) Symmetrical shape assures
foolproof assembly.
Can be disconnected and reused.
Watertight/oiltight installation at box or
enclosure termination is assured by:
1. External taper thread hub on
5331GR series and use of
sealing gasket 5262 series (G).
2. Taper tapped hole on 5271 series.
Suitable for use in Class I Division 2,
Class II Division 1 & 2 and Class III
Division 1 & 2 Hazardous Locations
per CEC Section 18.
• Conforms with JIC requirements.
CEC Rule 12-1306 stipulates “a
separate bonding conductor shall be
installed in liquidtight flexible conduit in
accordance with section 10”.
CEC Rule 10-618 (3) “The armour of
flexible metal conduit and liquidtight
flexible metal conduit shall not be
considered as fulfilling the
requirements of a bonding conductor
for the purposes of this rule, and a
separate bonding conductor shall
be run within the conduit”.
Standard Material
Lugs: High conductivity copper
(for copper conductor only).
Body, Gland, Locknut & Ground
Cones: All steel or malleable iron.
Sealing Ring and Insulator:
All thermoplastic
Sealing Gasket: Stainless Steel & Buna N
Strap: Steel
Standard Finish
All Electro Zinc Plated and Chromate
Coated except lugs.
Lugs: Bright Dipped
Range
5331GR Series (straight fittings with
male hub): 3¼8” thru 6” conduit.
5341GR Series (45°): 3¼8” thru 4” conduit
5351GR Series (90°): 3¼8” thru 4” conduit.
5271GR Series (straight fittings
with female hub): 3¼8” thru 1-1/4”
conduit.
All hubs provided with taper pipe threads
(NPT)
Conformity
U.L. 467
U.L. 514B
CSA C22.2 No. 18.3
CSA C22.2 No. 41
NEMA FB-1
NFPA 70-2008 (ANSI)
JIC EGP1
JIC EMP1
Federal Specification W-F-406
Federal Standard H-28 (threads)
Series 5331GR
Series 5271GR
Sleeving
Raceway Jacket pulls off—exposing core and
affecting liquidtight termination. Feature (E) on
sealing ring helps overcome this problem.
CONFITMRO_EN_ALL.pdf 95 11/28/2011 11:05:36 AM
96
T&B Conduit Fittings
Liquidtight Flexible Metal Conduit Fittings
Straight Grounding Fittings*
Cat. No. Ground
Steel Steel Aluminum Conduit Dimensions (in.) Wire
Insulated Non-insulated Non-insulated Size A B C D
5331GR** 5231GR 5231ALGR* 3/8” 1-5/32 1-1/2 9/16 14-8
5332GR 5232GR 5232ALGR* 1/2” 1-3/8 1-9/16 9/16 14-8
5333GR 5233GR 5233ALGR* 3/4” 1-21/32 1-5/8 9/16 14-4
5334GR 5234GR 5234ALGR* 1” 1-7/8 2-1/16 3/4 14-4
5335GR 5235GR 1-1/4” 2-1/4 2-1/2 13/16 8-1/0
5336GR 5236GR 1-1/2” 3-1/4 2-11/16 13/16 4-2/0
5337GR 5237GR 2” 3-13/16 3-1/16 7/8 4-2/0
5338GR 5238GR 2-1/2” 4-7/16 4-1/8 1 2-4/0
5339GR 5239GR 3” 5-3/16 4-1/4 1 2-4/0
5340GR 5240GR 4” 6-1/8 4-1/2 1-1/8 2-4/0
5385GR 5285GR 5” 8-9/16 7 1-7/8 2-4/0
5386GR — 6” 8-17/32 8-1/2 2 2-4/0
45° Angle Grounding Fittings
Ground
Cat. No. Conduit Dimensions (in.) Wire
Insulated Non-insulated Size A B C D
5341GR** 5241GR** 3/8” 1-5/32 1-9/16 9/16 14-8
5342GR 5242GR 1/2” 1-3/8 1-7/8 9/16 14-8
5343GR 5243GR 3/4” 1-21/32 2-1/8 9/16 14-4
5344GR 5244GR 1” 1-7/8 2-1/4 3/4 14-4
5345GR 5245GR 1-1/4” 2-1/4 2-3/4 13/16 8-1/0
5346GR 5246GR 1-1/2” 3-1/4 3-3/8 13/16 4-2/0
5347GR 5247GR 2” 3-13/16 3-7/8 7/8 4-2/0
5348GR 5248GR 2-1/2” 4-7/16 4-1/4 1 2-4/0
5349GR 5249GR 3” 5-3/16 4-1/4 1 2-4/0
5350GR 5250GR 4” 6-1/8 4-5/8 1-1/8 2-4/0
90° Angle Grounding Fittings
Cat. No. Ground
Steel Steel Aluminum Conduit Dimensions (in.) Wire
Insulated Non-insulated Non-insulated Size A B C D
5351GR** 5251GR** 5251ALGR* 3/8” 1-5/32 1-1/4 9/16 14-8
5352GR 5252GR 5252ALGR* 1/2” 1-3/8 1-7/16 9/16 14-8
5353GR 5253GR 5253ALGR* 3/4” 1-21/321-13/16 9/16 14-4
5354GR 5254GR 5254ALGR* 1” 1-7/8 2-1/16 3/4 14-4
5355GR 5255GR 1-1/4” 2-1/4 2-1/2 13/16 8-1/0
5356GR 5256GR 1-1/2” 3-1/4 2-15/16 13/16 4-2/0
5357GR 5257GR 2” 3-13/16 3-7/16 7/8 4-2/0
5358GR 5258GR 2-1/2” 4-7/16 8-7/8 1 2-4/0
5359GR 5259GR 3” 5-3/16 10-1/4 1 2-4/0
5360GR 5260GR 4” 6-1/8 12-5/8 1-1/8 2-4/0
* Not CSA Certified
** 3/8” conduit fittings have 1/2” trade size hub. With safe-edge ground cone (through 4”)
and double bevel sealing ring (through 2”).
Suitable for hazardous locations use in Class I, Division 2; Class II, Division 1 and 2; Class III,
Division 1 and 2, where general purpose equipment is specifically permitted per CEC Rule
18-152 (6) Class I, Zone 2; CEC Rule J18-156 (3) Class I, Division 2;
CEC Rule 18-202 (4) Class II, Division. 1; CEC Rule 18-252 (4) Class II, Division 2.
Note: 3/8”-1” fittings include Revolver grounding device. For sizes 1-1/4” and up, fittings are
supplied with a copper mechanical lug.
Malleable iron, tapered hub threads.
Malleable iron, tapered hub threads.
Malleable iron tapered hub threads.
A
B
C
Ground Wire
Max. over Ribs
Ground Wire
Max. over Ribs
CONFITMRO_EN_ALL.pdf 96 11/28/2011 11:05:36 AM
97
T&B Conduit Fittings
Liquidtight Flexible Metal Conduit Fittings
External Grounding Strap
Conduit A B
Cat. No. Size Swing Radius Bolt Size
GR1W 3/8” 1 10-24
GR2W 1/2” 1-1/16 10-24
GR3W 3/4” 1-3/8 1/4-20
GR4W 1” 1-1/2 1/4-20
GR5W 1-1/4” 1-7/8 5/16-18
Liquidtight to Rigid External Ground Adaptor
Conduit A B C
Cat. No. Size Overall Length Bolt Size Lug Range
5271GR*3/8” 1-15/32 10-24 14-8
5272GR 1/2” 1-3/8 10-24 14-8
5273GR 3/4” 1-21/32 1/4-20 14-4
5274GR 1” 1-7/8 1/4-20 14-4
5275GR 1-1/4” 2-1/4 5/16-18 8-1/0
5276GR 1-1/4” 2-29/32 3/8-16 3/8-16
* 3/8” conduit fittings have 1¼2” trade size hub.
For Dura-Platefinish add prefix 040- to Cat. No. Consult Customer Service for details.
Revolver®Grounding Device
Conduit
Cat. No. Size
38GR-TB 3/8”
12GR-TB 1/2”
34GR-TB 3/4”
1GR-TB 1”
The grounding device is a combination of a set screw and a grounding lug that can be used
to retrofit any existing liquidtight fithing to an externally grounded version.
A
For retrofit applications. Includes strap,
nut and bolt.
Swing
Radius Bolt
Bolt
Size
C Lug Range
CONFITMRO_EN_ALL.pdf 97 11/28/2011 11:05:36 AM
98
T&B Conduit Fittings
Liquidtight Flexible Metal Conduit Fittings
Specifications — PVC Coated
Gland
Sealing
Ring
Ground
Cone (D)
Body
Sealing
Gasket
Locknut (H)
3321 Series
(B)
(B)
(A)
(C)
(E)
(A)
(F)
Leading
Edge Raceway Core
Convolutions
(G)
(I)
Taper
Threaded Hub
(F)
Trailing
Edge
3321 Series*
*3361 Series...same as 3321, except 90°
3341 Series...same as 3321, except 45°
Application
Used where liquidtight flexible metal
conduit is installed in outdoor or
indoor locations where exposed to
environmental conditions that are
more than normally corrosive to
exposed surfaces.
To positively bond conduit to box
or enclosure.
Features
PVC coated to protect fitting from
extremely corrosive surroundings
without affecting integrity of electrical
grounding path (A).
Provided with overlapping sleeve
for additional seal (B).
Ability to install quickly with low
torque effort.
Ground cone design offers following
advantages:
(1) Compresses metallic convolutions;
provides high quality ground
contact with low impedance and
high raceway holding power (C).
(2) Single helical thread on ground
cone is easy to install without
cross threading; accepts variations
in raceway diameters and
convolution pitch (D).
(3) Rolled over edge protects
conductors (E).
Sealing ring design has following
exclusive features:
(1) Grips and seals at leading and
trailing edge—will not abrade
raceway jacket (F).
(2) Provided with grooves on inside
diameter for anti-sleeving (G).
(3) Shoulders on both ends for extra
sealing.
(4) Symmetrical shape assures
foolproof assembly.
Hardened steel or malleable iron
locknut (H).
Can be disconnected and reused.
Watertight/oiltight installation at box
or enclosure termination is provided
by external taper thread hub and
sealing gasket (I).
Suitable for use in Class I Division 2,
Class II Division 1, 2 and Class III
Division 1, 2 Hazardous Locations per
CEC Rule 18-152 (6) Class I, Zone 2;
CEC Rule J18-156 (3) Class I, Div. 2;
CEC Rule 18-202 (4) Class II, Div. 1;
CEC Rule 18-252 (4) Class II, Div. 2.
Conforms with JIC requirements.
Standard Material
Body, Gland, Locknut and Ground
Cones: All steel or malleable iron.
Sealing Ring and Insulator:
All thermoplastic
Sealing Gasket, Retainer: Stainless
Steel
Resilient Seal: Buna N
Coating: PVC
Standard Finish
Outside of body and gland:
PVC Coated .040 min. Thickness
Inside of body and gland:
Electro Zinc Plated and Chromate
Coated
Locknut, Sealing Gasket, and Retainer:
Electro Zinc Plated and
Chromate Coated
Range
3321, 3361 and 3341 Series
3¼8” thru 4” conduit.
All hubs provided with taper pipe
threads (NPT).
Conformity
U.L. 514B
CSA C22.2 No. 18.3
NEMA FB-1
NFPA 70-2008 (ANSI)
JIC EGP1
JIC EMP1
Federal Specification W-F-406
Federal Standard H-28 (THREADS)
CONFITMRO_EN_ALL.pdf 98 11/28/2011 11:05:37 AM
Corrosion Resistant PVC Jacketed
Liquidtight Fittings
Conduit Dimensions (in.)
Cat. No. Size A B C
Straight PVC Coated
3321 3/8 1-15/32 2-5/16 9/16
3322 1/2 1-5/8 2-1/2 9/16
3323 3/4 1-15/16 2-25/32 9/16
3324 1 2-1/4 3-15/32 3/4
3325 1-1/4 2-11/16 4-1/4 13/16
3326 1-1/2 3-1/8 4-11/16 13/16
3327 2 3-5/8 5-5/16 7/8
3328-TB 2-1/2 4-3/8 6-3/8 1
3329 3 5-3/16 6-1/2 1
3331 4 6-7/16 6-3/4 1-1/8
90° PVC Coated
3361 3/8 1-15/32 2-3/16 9/16
3362 1/2 1-5/8 2-1/2 9/16
3363 3/4 1-15/16 2-29/32 9/16
3364 1 2-1/4 3-19/32 3/4
3365 1-1/4 2-11/16 4-1/2 13/16
3366 1-1/2 3-1/8 4-15/16 13/16
3367 2 3-5/8 5-11/16 7/8
3368 2-1/2 4-3/8 11-1/8 1
3369 3 5-3/16 12-1/2 1
3371 4 6-7/16 14-7/8 1-1/8
45° PVC Coated
3341 3/8 1-15/32 1-1/8 9/16
3342 1/2 1-5/8 1-1/4 9/16
3343 3/4 1-15/16 1-7/16 9/16
3344-TB 1 2-1/4 1-13/16 3/4
3345 1-1/4 2-11/16 2-1/16 13/16
3346 1-1/2 3-1/8 2-11/16 13/16
3347 2 3-5/8 3-3/16 7/8
3348-TB 2-1/2 4-3/8 3-13/16 1
3349 3 5-3/16 4-9/16 1
3352 4 6-7/16 5-3/4 1-1/8
Complies with J.I.C. standards and Federal Specs W-F-406B, W-F-408B
Suitable for hazardous locations use in Class I, Div. 2; Class II, Div. 1 and 2; Class III, Div. 1
and 2, where general purpose equipment is specifically permitted per CEC Rule 18-156 (6)
Class I, Zone 2; CEC Rule J18-152 (3) Class I, Div. 2; CEC Rule 18-202 (4) Class II, Div. 1; CEC
Rule 18-252 (4) Class II, Div. 2.
99
T&B Conduit Fittings
Liquidtight Flexible Metal Conduit Fittings
Straight PVC Coated
Nylon Insulated
Steel or Malleable Iron
NPT hub threads
90° PVC Coated
Nylon Insulated
NPT hub threads
45° PVC Coated
Nylon Insulated
NPT hub threads
CONFITMRO_EN_ALL.pdf 99 11/28/2011 11:05:37 AM
100
T&B Conduit Fittings
Liquidtight Flexible Metal Conduit Fittings
Specifications Liquidtight Union for Threaded Hub
Liquidtight Union for Threaded Hub
Conduit Dimensions (in.)
Cat. No. Size A B
41TB 1/2” 1-29/64 1
42TB 3/4” 1-15/16 1-1/4
(E)
(C)
(D)
Gland
Resilient Seal
(A)
Body
(B)
Controlled Deformation
of Resilient Seal
41 Series
Steel, zinc plated and chromated. Ideal for angle
fittings where swing clearance is not available.
Application
To couple threaded end of a fitting or
a pipe to a tapped opening in a box
or enclosure where rotation of fitting
or pipe is limited or restricted.
Features
Provides high quality bond between
fitting or pipe to the union.
Provided with resilient seal (A).
Resilient seal subjected to controlled
deformation; positive seal and
reusability are assured (B).
Unique design centralizes throat
openings of threaded hub and union
(C).
Permits orientation of fitting in any
predetermined direction for a safe,
functional and neat assembly.
Provided with taper-threaded hub
for liquidtight assembly (D).
Straight pipe threads on gland accept a
straight-or taper-threaded hub on
fitting or pipe to be coupled (E).
Suitable for hazardous location
use per
CEC Rule J18-106 Class I, Div. 1;
CEC Rule 18-202 Class II, Div. 1;
CEC Rule 18-252 Class II, Div. 2;
CEC Rule 18-302 Class III, Div. 1;
CEC Rule 18-352 Class III, Div. 2;
Standard Material/Finish
Gland Steel/Electro Zinc
Chromate Coated
Body Steel/Electro Zinc
Chromate Coated
‘O’ Ring Buna N/As Molded
Range
Hub (External Thread)
1/2” and 3/4” NPT
Gland (Internal Threads)
1/2” and 3/4” NPS
Conformity
U.L. 514B
CSA C22.2 No. 18.3
NEMA FB-1
ANSI C80.4
NFPA 70-2008 (ANSI)
Federal Specification W-F-408
Federal Specification W-F-406
Federal Standard H-28 (Threads)
CONFITMRO_EN_ALL.pdf 100 11/28/2011 11:05:37 AM
101
T&B Conduit Fittings
Liquidtight Flexible Nonmetallic Conduit Fittings
Application
To provide a liquidtight, dustight
connection between flexible,
nonmetallic conduit and a box
or an enclosure.
Features
Serrated design provides high
mechanical pullout strength (A).
Unique component parts
(body/gland) design insures
positive seal between conduit
and fitting (B).
Tapered thread hub and sealing ‘O’
ring provide a liquidtight/dust tight
seal to a box or an enclosure (C).
High strength, chemical resistant,
non-burning, non-dripping
thermoplastic construction.
Smooth insulated body throughout
for maximum dielectric strength.
Captive ‘O’ ring and reduced number
of parts save installation time (D).
Standard Material
Body Thermoplastic
Gland Thermoplastic
‘O’ Ring Neoprene
Locknut Steel (Case Hardened)
Standard Finish
Body, Gland & ‘O’ Ring
As Molded
Locknut Electro Zinc
Range
Conduit Size 1/2” thru 1-1/4”
Hub Size 1/2” thru 1-1/4”
N.P.T.
Type A Liquidtight Flexible Nonmetallic
Conduit shall be seamless type
adequately reinforced with one or
more layers of flexible braided
reinforcing cords. Conduit jacket shall
be of non-kinking oil resistant/water
resis-tant flame retardant material
suitable for ambient environmental
conditions.
Where Type A Flexible Nonmetallic
Conduit terminates into a threaded
or threadless opening, the conduit
shall be cut square, deburred,
installed with sufficient slack to reduce
effects of vibration and assembled
with approved fittings such as series
6302 or 3720 manufactured by
Thomas & Betts. Fittings shall be of
malleable iron/steel/thermoplastic
construction with taper-threaded hub
and:
(1) Ferrous metallic fittings shall be
electro-zinc plated inside outside
and equipped with a nylon
insulated throat.
(2) Thermoplastic fittings shall be of
high impact chemical resistant,
non-burning, non-dripping
thermoplastic.
(3) Fittings shall be provided with a
captive, moisture resistant/oil
resistant synthetic rubber gasket.
Specifications Type A Conduit Fittings
Suggested Specifications for Type A Conduit and Fittings
(A) Left-Handed Threads
Gland
Body
Sealing ‘O’ Ring
Locknut
Liquidtight Flexible
Nonmetallic Conduit
Gland
Body
Sealing ‘O’ Ring
(C)
Taper Threaded Hub
(A & B)
(D)
Captive Sealing
‘O’ Ring
Series 6302
Liquidtight Flexible Nonmetallic
Conduit Fittings
Series 6322
Liquidtight Flexible Nonmetallic
Conduit Fittings
CONFITMRO_EN_ALL.pdf 101 11/28/2011 11:05:37 AM
102
T&B Conduit Fittings
Liquidtight Flexible Nonmetallic Conduit Fittings
Thermoplastic Fittings for Liquidtight Flexible
Nonmetallic Conduit Type A
Dimensions (in.)
ABC
Conduit Cross
Cat. No. Size Corners
Straight Fitting
6302 1/2” .60 1.68 1.48
6303 3/4” .61 1.85 1.76
6304 1” .77 1.89 2.10
6305 1-1/4” .79 2.30 2.67
90° Angle Fitting
6322 1/2” .60 1.56 1.48
6323 3/4” .61 1.74 1.76
6324 1” .77 1.78 2.10
6325 1-1/4” .79 2.13 2.67
Corrosion Resistant Applications
Meets Coast Guard CG293
*Use with our LNM-P Conduit on p. 146
Liquidtight Flexible Nonmetallic Conduit Type A
Conduit Dimensions (in.)
Cat. No. Size Hub Thread A B
3720-TB* 3/8 1/2—14 NPT 1-5/32 2
3721-TB 1/2 1/2—14 NPT 1-3/8 2-1/8
3722-TB 3/4 3/4—14 NPT 1-5/8 2-1/4
3723 1 1—11-1/2 NPT 1-7/8 2-1/2
3724-TB 1-1/4 1-1/4—11-1/2 NPT 2-3/8 2
3725 1-1/2 1-1/2—11-1/2 NPT 2-3/4 3-3/8
3726 2 2—11-1/2 NPT 3-17/32 3-5/8
* Not U.L. Listed
For Dura-Plate™ Finish, add prefix 040- to Cat. No. Consult Customer Service for details.
90° Angle Fitting
Designed especially for the Type A, all-plastic
raceways now in use for dynamic machine tool
applications.
Fittings are constructed of a high-strength,
chemically resistant thermoplastic tougher than
the raceway itself.
Neoprene sealing ring is furnished with
fitting providing a liquidtight seal for knockout
applications.
Straight Fitting
• Nylon insulated throat.
• T&B Sealing Ring to seal knockouts.
• Steel or malleable iron.
• U.L. Listed.
• NPT hub threads to seal in female threads.
• High mechanical pull-out strength.
Provides positive seal against water, oil and
dust.
CONFITMRO_EN_ALL.pdf 102 11/28/2011 11:05:38 AM
103
T&B Conduit Fittings
Liquidtight Flexible Metal Conduit Fittings
45° Metallic Fittings
Conduit Dimensions (in.)
Cat. No. Size Hub Thread A B
3730-TB* 3/8 1/2—14 NPT 1-5/32 2-13/32
3731-TB 1/2 1/2—14 NPT 1-3/8 2-9/16
3732 3/4 3/4—14 NPT 1-5/8 3
3733-TB 1 1—11-1/2 NPT 1-7/8 3-1/2
3734-TB 1-1/4 1-1/4—11-1/2 NPT 2-3/8 4-1/8
3735-TB 1-1/2 1-1/2—11-1/2 NPT 2-3/4 4-7/8
3736 2 2—11-1/2 NPT 3-17/32 5-1/2
* Not U.L. Listed
Available with Dura-Plate™ Finish. Consult Customer Service for details.
90° Metallic Fittings
Conduit Dimensions (in.)
Cat. No. Size Hub Thread A B
3740* 3/8 1/2—14 NPT 1-5/32 1-5/8
3741 1/2 1/2—14 NPT 1-3/8 1-3/4
3742 3/4 3/4—14 NPT 1-5/8 2-1/4
3743-TB 1 1—11-1/2 NPT 1-7/8 2-9/16
3744-TB 1-1/4 1-1/4—11-1/2 NPT 2-3/8 3-1/4
3745 1-1/2 1-1/2—11-1/2 NPT 2-3/4 3-1/2
3746-TB 2 2—11-1/2 NPT 2-17/32 4-1/8
* Not U.L. Listed
Available with Dura-Plate™ Finish. Consult Customer Service for details..
Liquidtight K.O. Plugs
Dimensions (in.)
Cat. No. Size A
5710 1/2” 1-9/32”
5711 3/4” 1-1/2”
5712 1” 1-27/32”
5713 1-1/4” 27/32”
5714 1-1/2” 2-1/2”
5715 2” 3-3/32”
5716 2-1/2” 3-21/32”
5717 3” 4-19/64”
5718 4” 5-19/64”
U.L. Listed liquidtight
CSA not applicable
Meets Coast Guard Regulation CG293
NEMA 3R, 4, 6 & 13
Temperature range — -30°C to 105°C.
A
CONFITMRO_EN_ALL.pdf 103 11/28/2011 11:05:38 AM
104
T&B Conduit Fittings
Liquidtight Flexible Metal Conduit Fittings
Specifications Liquidtight Sealing Gaskets
B Thickness
5262 Series
NEMA 3R, 4, 6 & 13
For use with T&B Fittings. Sealing material
resists oil, coolants, and hydraulic fluids as well
as water.
Application
When used with an externally
threaded fitting provides a tight seal
against oil, fumes or moisture at the
knockout opening.
Features
Locks resilient sealing material in
steel.
Steel retainer protects seal from
extruding out under torque and
limits compression to an optimum
predetermined value; provides high
quality seal.
Resilient material flows and
seals rough surfaces.
Standard Material
Retainer Stainless Steel
Sealing Material Buna N
Range
1/2” thru 4” Hub Size
Stainless Steel Retainer
Resilient Seal
Resilient Sealing
Material Locked in Steel Retainer
Sealing Ring with Stainless Steel Retainer
Conduit Dimensions (in.)
Cat. No. Size A B
5299** 1/4” .80 .11
5261** 3/8” .95 .11
5262 1/2” 1.16 .18
5263 3/4” 1.49 .19
5264 1” 1.75 .19
5265 1-1/4” 2.15 .22
5266 1-1/2” 2.42 .23
5267 2” 2.92 .23
5268 2-1/2” 3.44 .23
5269 3” 4.08 .23
5270 4” 5.29 .31
** U.L. not applicable
CONFITMRO_EN_ALL.pdf 104 11/28/2011 11:05:38 AM
105
T&B Conduit Fittings
Liquidtight Flexible Metal Conduit Fittings
PG Metric Thread Liquidtight Fittings*
Flexible Metric
Conduit PG Dimensions (mm)
Cat. No. Size Thread A B C
Nylon insulated straight fittings
7330** 1/4” 9 36 21 12
7360** 5/16 9 362612
7361* 3/8” 11 40 29 14
7362* 3/8” 13.5 40 29 14
7363* 1/2” 16 41 35 14
7364* 3/4” 21 43 42 14
7365 1” 29 56 47 19
7366 1-1/4” 36675821
7367 1-1/2” 42726921
7368 2” 48 81 83 21
Nylon insulated 45° angle fittings
7341 3/8” 11 27 29 14
7342 3/8” 13.5 27 29 14
7343 1/2” 16 30 35 14
7344-TB 3/4” 21 34 42 14
7345 1” 29 44 47 19
7346 1-1/4” 36515819
7347 1-1/2” 42606921
7348-TB 2” 48 73 76 24
Nylon insulated 90° angle fittings
7351 3/8” 11 37 29 14
7352 3/8” 13.5 37 29 14
7353 1/2” 16 40 35 14
7354 3/4” 21 44 42 14
7355 1” 29 56 47 21
7356 1-1/4” 36 70 58 21
7357 1-1/2” 42 75 69 21
7358 2” 48 87 83 24
U.L. Listed liquidtight.
*CSA Certified dusttight and watertight.
**U.L. not applicable and not CSA Certified.
Fittings for Liquidtight flexible metal conduit
with metric threads of PG Form (DIN 40430).
Liquidtight Flexible Metal/MS Fittings
Internal Thread
Trade AN-MS Conn. Dimensions (in.)
Cat. No. Size Shell Size Thread Size A B
LTA03810 3/8 10SL, 12, 12S 5/8—24 UNEF-2B 1-5/32 1
LTA03814 3/8 14, 14S 3/4—20 UNEF-2B 1-5/32 1
LTA05014 1/2 14, 14S 3/4—20 UNEF-2B 1-5/16 1-1/4
LTA05016 1/2 16, 16S 7/8—20 UNEF-2B 1-5/16 1-1/4
LTA05018 1/2 18 1—20 UNEF-2B 1-5/16 1-1/4
LTA07516 3/4 16, 16S 7/8—20 UNEF-2B 1-7/16 1-1/2
LTA07518 3/4 18 1—20 UNEF-2B 1-7/16 1-1/2
LTA07520 3/4 20, 22 1-3/16 —18 UNEF-2B 1-7/16 1-1/2
LTA10020 1 20, 22 1-3/16 —18 UNEF-2B 1-3/4 1-23/32
LTA10024 1 25, 28 1-7/16 —18 UNEF-2B 1-3/4 1-23/32
T&B Liquidtight flexible metal and Liquidtight
flexible nonmetallic fittings with internal
threads to accept AN-MS fitting shells.
Material: Steel
CONFITMRO_EN_ALL.pdf 105 11/28/2011 11:05:38 AM
106
T&B Conduit Fittings
Liquidtight Flexible Metal Conduit Fittings
ISO Metric Thread Liquidtight Fittings*
Flexible Metric
Conduit ISO Dimensions (mm)
Cat. No. Size Thread A B C
Nylon insulated straight fittings
9330 1/4” 16 36 21 12
9331 1/4” 20 36 21 12
9306 5/16” 16 36 26 12
9360 3/8” 16 40 29 16
9361 3/8” 20 40 29 16
9362 1/2” 20 42 35 16
9363 3/4” 25 45 42 16
9364 1” 32 54 47 23
Nylon insulated 45° angle fittings
9340 3/8” 16 27 29 16
9341 3/8” 20 27 29 16
9342 1/2” 20 27 35 16
9343TB 3/4” 25 31 42 16
9344 1” 32 34 47 23
Nylon insulated 90° angle fittings
9350 3/8” 16 35 29 16
9351 3/8” 20 35 29 16
9352TB 1/2” 20 39 35 16
9353TB 3/4” 25 43 42 16
9354TB 1” 32 48 47 23
U.L. Listed Liquidtight.
NPT/MS Fitting Adaptors
AN-MS
N.P.T. Fitting Thread Dimensions (in.)
Cat. No. Thread Shell Size Size A Fig. B
MSA05014 1/2” 14, 14S 3/4—20 UNEF-2B 1.000 1 1.175
MSA05016 1/2” 16, 16S 7/8—20 UNEF-2B 1.000 2 1.175
MSA05018 1/2” 18 1—20 UNEF-2B 1.125 3 1.175
MSA07516 3/4” 16, 16S 7/8—20 UNEF-2B 1.250 1 1.356
MSA07518 3/4” 18 1—20 UNEF-2B 1.250 1 1.300
MSA07520 3/4” 20, 22 1-3/16 —18 UNEF-2B 1.375 3 1.300
MSA10020 1 20, 22 1-3/16 —18 UNEF-2B 1.500 1 1.431
MSA10024 1 24, 28 1-7/16 —18 UNEF-2B 1.625 3 1.313
MSA10032 1 32 1-3/4—18 UNS-2B 2.000 3 1.576
MSA10036 1 36 2—18 UNS-2B 2.250 3 1.738
Not CSA Certified.
Fittings for Liquidtight flexible metal conduit with
metric threads of ISO Form (BS-4568-SA BS 162).
B
A
B
A
Fig. 1
Fig. 2
Fig. 3
Mechanical adapter with internal threads to
mate with NPT threaded fittings and MS type
fittings.
Material: aluminum
CONFITMRO_EN_ALL.pdf 106 11/28/2011 11:05:38 AM
107
T&B Conduit Fittings
Liquidtight Flexible Nonmetallic Conduit Fittings
Specification Sheet—Bullet®Liquidtight Fittings for
Liquidtight Flexible Nonmetallic Conduit and Tubing
Box or
Enclosure
Wall
Conduit
or Tubing
Application:
A series of nonmetallic fittings designed
to provide a liquidtight seal when
terminating liquidtight nonmetallic
conduit (U.L. Type B) or liquidtight
nonmetallic tubing to a box or enclosure
with knockout opening or a threaded
hub.
Plastic Bullet®Liquidtight Fittings
Feature:
Fitting assembles to conduit without
disassembly and is designed to be
installed with positive installation
criteria (gland bottoms on body
shoulder).
Rugged low profile nonmetallic body
and gland construction (1); the fitting is
equipped with a steel locknut to firmly
secure fitting to box or an enclosure
and a sealing “O” ring.
Captive sealing “O” ring (2) with
predetermined compression for a
reliable seal at enclosure.
Fitting ferrule designed to accept
variations in conduit inside diameter
and is tolerant of field conduit cuts (3).
Ferrule profile designed to reduce
friction between conduit I.D. and
ferrule (4) allowing conduit to seat
properly for an effective seal.
Outer surface of clamping fingers
provided with friction reducing ridges
(5) for ease of installation; the inner
surface is designed with conduit
biting teeth to enhance clamping and
sealing action (6).
Performance of fittings tested to
simulate adverse installation
conditions.
Provides a double sealing action (7).
Elongated gland nut profile (8)
designed to provide additional strain
relief for 90° pull and an easy hand
grip.
Performance of fitting unaffected by
exposure to detergents, cleaners, and
sanitizers commonly encountered in
food processing plants and typical
industrial environment; also
unaffected by cutting fluids, wiring
pulling compounds and Marine
environment.
Meets industry standards for cold
impact and simulated hammer blow.
Standard Material/Finish:
Body Gland—weather stabilized
thermoplastic (black).
“O” Ring—nitrile (blue)
Locknut—Steel/electro-zinc plated
Material temperature rating—
thermoplastic -40°C to 105°C.
Material Flammability Rating:
U.L.94-V2.
Conformity
CSA C22.2 #227.2 & CSA
C22.2 #227.3
• U.L.514B
Watertight requirements of NEMA
Type 4 and Type 4X.
Federal Standard H-28 (NPT threads)
There is no CEC Rule to use
Nonmetallic liquidtight conduit and
fittings in Class I, Zone 2 or Class I,
Division 2;
Rule 18-202 (4) (b) Class II, Division 1;
Rule 18-252 (4) Class II, Division 2; Rule
18-302 (4) Class III, Division 1.
CONFITMRO_EN_ALL.pdf 107 11/28/2011 11:05:38 AM
108
T&B Conduit Fittings
Liquidtight Flexible Nonmetallic Conduit Fittings
Plastic Bullet®Liquidtight Fittings for T&B NMC
Nonmetallic Liquidtight Conduit Type B and T&B NMT Flexible Tubing
C ±.015 (0.40) Min.
A ±.015 Across Throat E F*
Trade (.040) *B ±.035 (0.90) Corners Dia. D Thread (in.) (mm)
Cat. No. Fig. Size in. (mm) in. (mm) in. (mm) in. (mm) NPT Approx.
LT38P 1.570 1.595 (40.51) 1.354 .417
LT438P 2 3/8 2.012 (51.10) 1/2-14 1.534 (38.95)
LT938P 3(14.48) 1.380 (35.05) (34.39) (10.59) 1.880 (47.75)
LT50P 1.570 1.636 (41.55) 1.448 .550
LT450P 2 1/2 2.092 (53.14) 1/2-14 1.590 (40.39)
LT950P 3(14.48) 1.489 (37.82) (36.78) (13.97) 1.986 (50.44)
LT75P 1.582 1.757 (44.63) 1.740 .740
LT475P 2 3/4 2.452 (62.28) 3/4-14 1.821 (46.25)
LT975P 3(14.78) 1.790 (45.47) (44.20) (18.80) 2.212 (56.00)
LT100P 1.726 1.923 (48.84) 2.068 .940
LT4100P 2 1 2.684 (68.17) 1-11-1/2 2.034 (51.66)
LT9100P 3(18.44) 2.104 (53.44) (52.53) (23.88) 2.508 (63.70)
LT125P 1.750 2.164 (54.97) 2.494 1.257
LT4125P 2 1-1/4 3.264 (82.91) 1-1/4-11-1/2 2.385 (60.58)
LT9125P 3(19.05) 2.564 (65.13) (63.35) (31.93) 2.856 (72.54)
LT150P 1.767 3.353 (59.77)
LT4150P 2 1-1/2 3.605 (91.57) 2.784 1.453 1-1/2-11-1/2 2.604 (66.14)
LT9150P 3(19.48) 2.854 (72.49) (70.71) (36.91) 3.144 (79.86)
LT200P 1.794 2.605 (66.17) 3.362 1.883
LT4200P 2 2 4.210 (106.93) 2-8 3.050 (77.47)
LT9200P 3(20.17) 3.432 (87.17) (85.39) (47.83) 3.675 (93.34)
* After Assembly
Figure 1 Figure 2 Figure 3
E Thread E Thread E Thread
Suggested Specification:
Where liquidtight flexible nonmetallic
conduit (U.L. and CSA Type B) or
liquidtight flexible nonmetallic tubing
is terminated to a box or enclosure, the
nonmetallic fittings used shall be able to
be installed without disassembly and
provide a positive installation criteria. In
the installed condition, the fitting must
provide a seal meeting watertight
requirements of NEMA Type 4 and Type
4X. The performance of fittings shall be
unaffected by exposure to detergents,
sanitizers, cutting fluids, wire pulling
compunds and oil-based industrial
paints. The fitting must also be capable
of withstanding marine environment and
cold impact simulating a hammer blow.
Installed fittings shall be of the
elongated gland type as
manufactured by Thomas & Betts
LT38P series.
CONFITMRO_EN_ALL.pdf 108 11/28/2011 11:05:39 AM
109
T&B Conduit Fittings
Liquidtight Flexible Conduit Fittings
Metallic Bullet®Liquidtight Fittings for T&B NMC
Non metallic Liquidtight Conduit Type B and T&B NMT Flexible Tubing
A ±.030* B ±.060 C ±.045
Trade (.80) (1.50) (1.15) D Thread
Cat. No. Fig. Size in. (mm) in. (mm) in. (mm) in. (mm) NPT
LT38M 11.156 1.500 (38.1) 0.562 (14.3)
LT438M 2 3/8 1.962 (49.8) 0.562 (14.3) 1/2-14
LT938M 3(29.4) 1.312 (33.3) 0.625 (15.9) 1.375 (34.9)
LT50M 11.375 1.562 (39.7) 0.562 (14.3)
LT450M 2 1/2 1.875 (47.6) 0.562 (14.3) 1/2-14
LT950M 3(34.9) 1.437 (36.5) 0.625 (15.9) 1.562 (39.7)
LT75M 11.656 1.625 (41.2) 0.625 (15.9)
LT475M 2 3/4 2.125 (54.0) 0.562 (14.3) 3/4-14
LT975M 3(42.1) 1.750 (44.4) 0.625 (15.9) 1.750 (44.4)
LT100M 11.875 2.062 (52.4) 0.750 (19.0)
LT4100M 2 1 2.250 (57.1) 0.812 (20.6) 1-11-1/2
LT9100M 3(47.6) 1.937 (49.2) 0.812 (20.6) 2.187 (55.5)
LT125M 12.375 2.500 (63.5) 0.812 (20.6)
LT4125M 2 1-1/4 2.750 (69.8) 0.812 (20.6) 1-1/4-11-1/2
LT9125M 3(60.3) 2.500 (63.5) 0.812 (20.6) 2.750 (69.8)
LT150M 12.750 2.687 (68.2) 0.812 (20.6)
LT4150M 2 1-1/2 2.750 (69.8) 0.812 (20.6) 1-1/2-11-1/2
LT9150M 3(69.8) 2.812 (71.4) 0.812 (20.6) 2.937 (74.6)
LT200M 13.468 3.062 (77.8) 0.812 (20.6)
LT4200M 2 2 3.875 (98.4) 0.875 (22.2) 2-11-1/2
LT9200M 3(88.1) 3.500 (88.9) 0.875 (22.2) 3.437 (87.3)
*After Assembly
Suggested Specification:
Where liquidtight flexible nonmetallic
conduit (U.L. and CSA Type B) or
liquidtight flexible nonmetallic tubing is
terminated to a box or enclosure, the
metallic fittings used shall be able to be
installed without disassembly and provide
positive installation criteria. In the installed
condition, the fitting must provide a seal,
meeting watertight requirements of NEMA
Type 4 and Type 4X with conduit and
NEMA Type 4 enclosures with tubing.
Installed fittings shall be as manufactured
by Thomas & Betts LT38M series.
Material: Body/Gland—Steel/MI
Insert—Nylon
Figure 1 Figure 2 Figure 3
CONFITMRO_EN_ALL.pdf 109 11/28/2011 11:05:39 AM
110
T&B Conduit Fittings
Liquidtight Flexible Nonmetallic Conduit Fittings
When you have a conduit application in a liquidtight environment, it's time to load
up the T&B Bullet®. Thomas & Betts introduces the ISO Metric Bullet®liquidtight
fittings for use with the 3/8”, 1/2”, and 3/4” NMT and NMC nonmetallic
liquidtight conduit series.
The T&B Bullet®liquidtight fitting and NMT nonmetallic conduit
are suited for OEM applications as in the machine tool industry
where environments include continuous motion, vibration,
and exposure to moisture, oil, dirt and dust.
The T&B Bullet®liquidtight fitting and NMT nonmetallic conduit
are also suitable for construction applications where ISO
metric threading and liquidtight systems are installed.
The Xtraflex®system offers a lightweight, liquidtight flexible
conduit solution for industrial applications. The Xtraflex®
system allows fast, easy installation and high performance
in demanding industrial applications.
ISO Metric Bullet®Liquidtight Fitting
Cat. Angle Conduit Knockout Unit Standard UPC
No. of Fitting Size (in.) Size (in.) Package Package Number
LT38M-ISO20 Straight 3/8 1/2 25 100 786210-62281
LT50M-ISO20 Straight 1/2 1/2 25 100 786210-62282
LT75M-ISO25 Straight 3/4 3/4 25 50 786210-62283
LT438M-ISO20 45° 3/8 1/2 25 50 786210-62284
LT450M-ISO20 45° 1/2 1/2 25 50 786210-62285
LT475M-ISO25 45° 3/4 3/4 10 50 786210-62286
LT938M-ISO20 90° 3/8 1/2 25 50 786210-62288
LT950M-ISO20 90° 1/2 1/2 25 50 786210-62289
LT975M-ISO25 90° 3/4 3/4 10 50 786210-62290
ISO Metric Bullet®Liquidtight Fitting Nonmetallic
Cat. Angle Conduit Knockout Unit Standard UPC
No. of Fitting Size Size Package Package Number
LT38P-ISO20 Straight 3/8” 1/2” 25 100 786210-66444
LT50P-ISO20 Straight 1/2” 1/2” 25 100 786210-66613
LT75P-ISO25 Straight 3/4” 3/4” 25 50 786210-66443
LT938P-ISO20 90° 3/8” 1/2” 25 50 786210-66612
LT950P-ISO20 90° 1/2” 1/2” 25 50 786210-66640
LT975M-ISO25 90° 3/4” 3/4” 10 50 786210-66611
ISO Metric BulletLiquidtight Fittings
CONFITMRO_EN_ALL.pdf 110 11/28/2011 11:05:39 AM
111
T&B Conduit Fittings
Armoured Cable and Flexible Metal Conduit Fittings
Armoured Cable (Type AC90)
Ref. CEC Rule 12-600
The Canadian Electric Code 2009 Part I
defines type AC armoured cable as,
“A fabricated assembly of insulated
conductors in a flexible metallic
enclosure.”
All armoured cables may employ
copper or aluminum or copperclad
aluminum conductors with the following
sizes and are rated for 600 volts or less:
No. 14 AWG to No. 1 AWG Copper
No. 12 AWG to No. 1 AWG Aluminum
or Copperclad Aluminum
Armoured cable can be used for both
exposed or concealed locations.
Armoured cable is not permitted in
locations where it will be subjected to
physical damage or corrosive fumes.
Armoured cable cannot be used for
direct burial in earth.
Codes require that cable shall be
supported with straps or staples
without damaging conductors. Certain
precautions are prescribed in code
where cable is installed through joist
rafters or similar wood members.
According to CEC Rule 12-610
(1) Where conductors issue from
armour, they shall be protected from
abrasion by bushings of insulating
material or equivalent devices.
(2) Where conductors are No. 10 AWG
or larger, copper or aluminum, such
protection shall consist of:
(a) Insulated type bushings, unless
the equipment is equipped with a
hub having a smoothly rounded
throat; or
(b) Insulating material fastened
securely in place which will separate
the conductors from armoured cable
fittings and afford adequate
resistance to mechanical injury.
(3) Where armoured cable is fastened to
equipment, the conductor or clamp
shall be of such design as to leave
the insulating bushing or its
equivalent visible for inspection.
(4) Where conductors connected to
open wiring issue from the ends of
armouring, they shall be protected
with boxes or with fittings having a
separately bushed hole for each
conductor.
Please refer to the following for further
details and complete information:
1. U.L. 4, ANSI C33.9….............Safety
Standards for Armoured Cable
2. U.L. 514.................................Safety
Standards for Outlet Boxes
and Fittings
3. W-F-406… .....Federal Specification:
Fittings for Cable, Power, Electrical
and Conduit, Metal, Flexible
4. NEMA FB-1… ..Standards Publication:
Fittings & Supports for Conduit
and Cable Assemblies
5. CEC Section 12-600… ..........Wiring
Methods (Armoured Cable)
6. CSA C22.2 No. 51… .............Safety
Standards for Armored Cables
7. CSA C22.2 No. 18… .............Safety
Standards for Outlet Boxes,
Conduit Boxes and Fittings
Specifications Armoured Cable and Flexible Metal Conduit
Please Note
The excerpts and other material herein, whether relating to the Canadian Electrical
Code 2009 Part I, the Underwriters Laboratories, Inc. listing, to
industry practice or otherwise, is not intended to provide all relevant information
required for use and installation. Reference to original or primary source
material and data is mandatory before any application or use is made of the
product.
CONFITMRO_EN_ALL.pdf 111 11/28/2011 11:05:39 AM
112
T&B Conduit Fittings
Armoured Cable and Flexible Metal Conduit Fittings
Flexible Metal Conduit
Ref. CEC Rule 12-1000
Flexible metal conduit can be used for
exposed or concealed work in dry
locations. It can be used for wet
locations provided conductors within
are lead covered or other approved
type.
Flexible metal conduit cannot be
used underground or embedded in
poured concrete or aggregate. With
rubber covered conductors the conduit
cannot be exposed to oil, gasoline or
other materials having a deteriorating
effect on rubber.
With minor exceptions use of flexible
metal conduit is not permitted in hoists,
in storage battery rooms and in any
hazardous locations. Use of flexible metal
conduit is restricted to systems under
600 volts.
Flexible metal conduit longer than six
feet is permitted to be used as a
grounding means provided the conduit
and the fitting are approved for the
purpose. To date there is no flexible
metal conduit approved for the purpose
by the Underwriters Laboratories or CSA.
In Class II Zone 2 and Division 2
hazardous areas, the conduit itself
cannot be used as the grounding
means. Class I Zone 2, flexible
connections at motor terminals and
similar places, ref.: CEC Rule 18-152 (6)
and Bonding CEC Rule 18-074 (1)(a).
Class I Division 2, flexible connections at
motor terminals and similar places, ref:
CEC Rule J18-152 (3) and Bonding CEC
Rule J18-072 (1)(a). Flexible metal
conduit is available with steel or
aluminum armour in trade size 5/16” to
4”. With few exceptions where 5/16 and
3/8 trade sizes are used, Code prohibits
use of conduit less than 1/2” trade size.
Bends in concealed work are restricted
to four 90° bends CEC Rule 12-940. No
angle fittings are permitted in concealed
raceway installations.
Please refer to the following for further
details and complete information:
1. U.L. 1, ANSI C33.92…...........Safety
Standards for Flexible Metal Conduit
2. U.L. 514.................................Safety
Standards for Outlet Boxes
and Fittings
3. W-F-406… .....Federal Specification:
Fittings for Cable, Power,Electrical
and Conduit, Metal Flexible
4. WW-C-566… .....Federal Specification:
Conduit, Metal, Flexible
5. NEMA FB1… Standards Publication:
Fittings and Supports
for Conduit and Cable Assemblies
6. CEC 12-1000… ........Wiring Method
(Rigid & Flexible Conduit)
7. CSA C22.2 No. 56… .............Safety
Standards for Flexible Metallic
Conduit and Liquid-Tight Flexible
Metal Conduit
8. CSA C22.2 No. 18… .............Safety
Standards for Outlet Boxes, Conduit
Boxes and Fittings
9. CEC Rule 12-1000
Rule 18-152 (6) and Bonding Rule
18-074 (1)(a) Class I, Zone 2 Flexible
connections at motor terminals and
similar places.
Rule J18-152 (6) and Bonding Rule
J18-072 (1)(a) Class I, Division 2
Flexible connections at motor
terminals and similar places.
Rule 12-940 ........Not more than the
equivaleent of four 90° bends CEC
Specifications Armoured Cable and Flexible Metal Conduit (continued)
CONFITMRO_EN_ALL.pdf 112 11/28/2011 11:05:39 AM
113
T&B Conduit Fittings
Armoured Cable and Flexible Metal Conduit Fittings
Suggested Specifications for Armoured Cable and Flexible
Metal Conduit Fittings
Series 3110
Armoured Cable Fitting
& Flexible Metal Conduit
Series 422
Insuliner Sleeve
Series 390
Anti Short Bushing
Armoured cable and flexible metal
conduit shall conform to provisions of
following applicable standards:
Armoured Cable…U.L. 4/ANSI
C33.9/CSA C22.2 No. 51
Flexible Metal Conduit…U.L. 1/ANSI
C33.92/WW-C-566/CSA C22.2 No.56
Type of cable used and conductors
within flexible metal conduit shall be
suitable for conditions of use and
location.
Where armoured cable or flexible
metal conduit terminates into a
threadless or threaded opening it
shall be assembled with approved
fittings; fittings shall be of malleable
iron/steel construction, electro-zinc
plated inside outside, equipped with
nylon insulated throat and shall be of
angled saddle type as manufactured
by Thomas & Betts, series 3110.
Direct bearing screw type
fittings shall not be used.
Suitable bushing as manufactured by
Thomas & Betts, series 422 or 390,
shall be provided between
the conductors and armour.
Where approved armoured cable or
flexible metal conduit is used as an
equipment grounding conductor
terminating fitting used shall be of the
grounding type as manufactured by
Thomas & Betts, series 3110.
CONFITMRO_EN_ALL.pdf 113 11/28/2011 11:05:40 AM
114
T&B Conduit Fittings
Armoured Cable and Flexible Metal Conduit Fittings
Application
To connect and effectively bond
armoured cable or flexible metal
conduit to a box or an enclosure.
Features
Provided with a saddle designed to:
(1) Firmly secure conduit in place
without damaging cable armour
(Mechanical holding power of
angled wedge assembly increases
with increased strain.).
(2) Provide high quality bond
between conduit or cable and are
unaffected by vibrations.
(3) Centralize conduit or cable with
respect to throat opening for
conductors.
Insulated throat protects conductors
during and after installation, reduces
wire pull effort and prevents thread
damage in handling.
Locknuts designed to provide
effective bond between fitting and
box or enclosure, will not vibrate
loose.
Designed with fewer screws—
reduces installation time and cost.
Rugged all steel or malleable iron
construction.
CEC Rule 18-152 (6) and Bonding
Rule 18-074 (1)(a) Class I, Zone 2
Flexible connections at motor
terminals and similar places.
CEC Rule J18-152 (6) and Bonding
Rule J18-072 (1)(a) Class I, Division 2
Flexible connections at motor
terminals and similar places.
Standard Material/Finish
Body: Steel or malleable iron/
Electro Zinc Plated &
Chromate Coated
Saddle: Steel/Electro Zinc Plated
& Chromate Coated
Screws: Steel/Electro Zinc Plated
& Chromate Coated
Insulator: Thermoplastic/As
Molded
Conformity
U.L. 514B
CSA C22.2 No. 18.3
NEMA FB-1
Specifications
3110 Series
Cable
Series Hub Size Conduit Size Opening
3110 Series 1/2" thru 5" NPS 3/8" thru 5" .437" to
Straight Fittings 5.500"
3130 Series 90° Fittings 1/2" thru 4" NPS 3/8" thru 4" .437" to
4.560"
(All hubs provided with
straight pipe threads NPS.)
Locknut Saddle
Typical
Installation
Body
Box or Enclosure Wall
Insulated Throat
CONFITMRO_EN_ALL.pdf 114 11/28/2011 11:05:40 AM
115
T&B Conduit Fittings
Armoured Cable and Flexible Metal Conduit Fittings
Tite-Bite®Fittings—Nylon Insulated
Cable Opening (in.) Trade K.O. Dimensions (in.)
Cat. No. max. min. Size Size A B C
3110-C*.656 .437 3/8” 1/2” 1-7/16 1-5/16 7/16
3112 .937 .750 1/2” 1/2” 1-25/32 1-3/4 1-9/32
3115*1.125 .906 3/4” 3/4” 2 1-3/4 1-9/32
3117*1.468 1.250 1” 1” 2-3/8 1-3/4 1-7/32
31181.750 1.562 1-1/4” 1-1/4” 2-3/4 2 1-11/32
31192.031 1.812 1-1/2” 1-1/2” 3-1/8 2-5/8 1-7/8
31202.500 2.312 2” 2” 3-3/4 2-3/4 1-15/16
31213.062 2.812 2-1/2” 2-1/2” 4-3/8 3-1/4 2-3/8
31223.562 3.312 3” 3” 5 3-1/4 2-3/8
31234.060 3.620 3-1/2” 3-1/2” 5-1/4 3-11/16 2-15/32
3124**4.560 4.120 4” 4” 5-3/4 3-25/32 2-1/2
3125** 5.500 4.600 5” 5” 6-7/8 4-27/32 3
Material: Steel thru 3/4” trade size.
* U.L. Listed for armoured cable only.
U.L. Listed for flexible metal conduit only.
CSA not applicable.
** Not U.L. Listed or CSA Certified.
Tite-Bite®Fittings
Cable Opening (in.) Trade K.O. Dimensions (in.)
Cat. No. max. min. Size Size A B C
300-TBC* .656 .437 3/8” 1/2” 7/16 1-5/16 7/16
302-C .937 .750 1/2” 1/2” 1-7/64 1-11/16 3/4
304 1.093 .906 3/4” 3/4” 1-7/32 1-11/16 29/32
306 1.468 1.250 1” 1” 1-1/8 1-3/4 1-1/4
3081.750 1.562 1-1/4” 1-1/4” 1-1/4 2-1/32 1-9/16
3102.031 1.812 1-1/2” 1-1/2” 1-3/4 2-9/16 1-13/16
3122.500 2.312 2” 2” 1-13/16 2-13/16 2-5/16
3143.062 2.812 2-1/2” 2-1/2” 2-1/4 3-1/8 2-13/16
3163.562 3.312 3” 3” 2-1/4 3-3/16 3-5/16
Material: Steel thru 3/4” trade size.
* U.L. Listed for armoured cable only.
U.L. Listed for flexible metal conduit only.
Steel or malleable iron.
The tough lining of insulation and the Tite-Bite
principles make these fittings a “must” when
conductors are subject to conditions of vibration
or strain.
Steel or malleable iron.
Easy to install with double grip saddle. These
fittings are completely salvageable. The 2/3”
and 1/2” sizes are made of formed steel which
produce a uniform high quality and a smooth
throat that protects conductor insulation. 3/4”
and larger size are malleable iron.
CONFITMRO_EN_ALL.pdf 115 11/28/2011 11:05:40 AM
116
T&B Conduit Fittings
Armoured Cable and Flexible Metal Conduit Fittings
Tite-Bite®Fittings90° Angle Nylon Insulated
Cable Opening (in.) Trade K.O. Dimensions (in.)
Cat. No. max. min. Size Size A B C
3130-C .563 .437 3/8” 1/2” 1-11/32 1-19/32 5/32
3132 .937 .750 1/2” 1/2” 1-7/8 2-5/16 1-5/32
3135 1.093 .906 3/4” 3/4” 2 2-1/8 1-5/32
3137 1.468 1.250 1” 1” 2-21/32 2-1/8 1/2
31381.750 1.562 1-1/4” 1-1/4” 3-1/8 2-7/8 3/4
31392.031 1.812 1-1/2” 11-1/2” 4-3/8 4 1-3/16
31402.500 2.312 2” 2” 5-9/16 4-7/8 1
31413.062 2.812 2-1/2” 2-1/2” 5-25/32 6 21
31423.562 3.312 3” 3” 6 7 1
31434.060 3.620 3-1/2” 3-1/2” 6 6-7/8 1-1/16
3144-TB4.560 4.120 4” 4” 6-29/32 7-1/4 1-1/8
U.L. Listed for flexible metal conduit only.
Not U.L. Listed or CSA Certified.
Tite-Bite®Fittings 90° Angle
Cable Opening (in.) Trade K.O. Dimensions (in.)
Cat. No. max. min. Size Size A B C
321-C .656 .437 3/8” 1/2” 1-11/32 1-1/2 3/8
323 .937 .750 1/2” 1/2” 1-7/8 2-3/8 1-7/32
325 1.093 .906 3/4” 3/4” 2-1/8 2-1/8 3/4
326-TB 1.468 1.250 1” 1” 2-21/32 2-1/8 1
3271.750 1.562 1-1/4” 1-1/4” 3-1/8 3-5/8
3282.031 1.812 1-1/2” 1-1/2” 4-1/8 4-1/8
3292.500 2.312 2” 2” 4-3/8 4-31/32
330-TB3.062 2.812 2-1/2” 2-1/2” 6-1/2 6
3313.562 3.312 3” 3” 5-25/32 7
U.L. Listed for flexible metal conduit only.
The angle clip gives secure mechanical grip that
tightens under tension or vibration. Throat is
long enough to install in cast housing
knockouts. The 3/8” and 1/2” sizes are of steel
construction. The 3/4” and larger sizes are
malleable iron.
Steel or malleable iron.
Available with or without insulated throat, this
Tite-Bite fitting line is by far the easiest and best
to install when making sharp bends at the
enclosure or equipment. It has all of the
advantages of the straight fitting with only one
screw to tighten, except in the larger sizes where
there are two. A peep hole on top provides for easy
inspection of the ABC bushing. Narrow design
makes it easy to install fittings in adjacent
knockouts.
CONFITMRO_EN_ALL.pdf 116 11/28/2011 11:05:40 AM
117
T&B Conduit Fittings
Armoured Cable and Flexible Metal Conduit Fittings
Squeeze Fittings
Cable Opening (in.) Trade K.O. Dimensions (in.)
Cat. No. max. min. Size Size A B C
252 .531 .437 5/16” 3/8” 13/16 25/32 11/32
253-TB.585 .455 3/8” 1/2” 31/32 1-13/64 5/8
254-C.938 .812 1/2” 1/2” 1-7/32 1-3/8 13/32
255 1.094 .938 3/4” 3/4” 1-1/4 1-17/32 7/16
256 1.375 1.250 1” 1” 1-19/32 1-5/8 1/2
257 1.656 1.500 1-1/4” 1-1/4” 1-7/8 1-23/32 17/32
258 1.875 1.688 1-1/2” 1-1/2” 2-1/4 1-7/16 9/16
259 2.500 2.313 2” 2” 2-31/32 2-5/8 11/16
249 3.062 2.812 2-1/2” 2-1/2” 3-5/16 2-11/16 3/4
277 3.563 3.312 3” 3” 3-13/16 2-7/8 3/4
U.L. Listed for armoured cable only. Fitting material steel.
Squeeze Fittings—90° Angle
Cable Opening (in.) Trade K.O. Dimensions (in.)
Cat. No. max. min. Size Size A B C
266-C* .656 .406 3/8” 1/2” 1-1/2 1-13/32 1-7/16
272.812 .688 3/8” 1/2” 1-9/16 1-7/8 1-9/16
268-C .937 .813 1/2” 1/2” 1-11/16 1-13/16 1-7/8
279 1.000 .875 3/4” 3/4” 1-13/16 2-1/16 1-13/16
270 1.125 1.000 3/4” 3/4” 1-7/8 1-3/4 1-13/16
273-TB 1.406 1.187 1” 1” 2-3/8 2-7/32 2-7/16
2741.656 1.375 1-1/4” 1-1/4” 3 2-9/16 2-7/8
2751.875 1.625 1-1/2” 1-1/2” 3-7/32 3-1/16 4-1/8
2762.500 2.125 2” 2” 4-5/8 3-5/8 4-7/8
U.L. Listed for armoured cable only.
U.L. Listed for flexible metal conduit only.
Squeeze Fittings—45° Angle
Cable Opening (in.) Trade K.O. Dimensions (in.)
Cat. No. max. min. Size Size A B C
265* .656 .406 3/8” 1/2” 1-7/16 1-5/32 1-1/8
267 .937 .813 1/2” 1/2” 1-3/16 1/2 1-1/4
269 1.125 1.000 3/4” 3/4” 1-7/8 17/32 1-9/16
T&B squeeze fittings will fit every size of
armoured cable, leaded cable and flexible
conduit. Malleable iron or steel construction.
Part No. 253-TB is steel.
3/8” and 1/2” sizes made in steel. Cap lifts off by
simply loosening screws part way. Only two
screws to tighten. 3/4” size and larger made
of malleable iron.
3/8” and 1/2” sizes made in steel. Cap lifts off by
simply loosening screws part way.
CONFITMRO_EN_ALL.pdf 117 11/28/2011 11:05:40 AM
118
T&B Conduit Fittings
Armoured Cable and Flexible Metal Conduit Fittings
Two-Screw Fittings
Cable Opening (in.) Trade K.O. Dimensions (in.)
Cat. No. max. min. Size Size A B C
3301-C* .656 .250 3/8” 1/2” 5/8 1-5/16 1-3/16
3312-C .937 .500 1/2” 1/2” 5/8 1-5/16 1-3/16
* U.L. Listed for armoured cable only.
Duplex Clamp Fitting
Dimensions (in.)
Cat. No. K.O. Size A B
291-C 1/2” 1-13/32” 1-11/16”
U.L. Listed as grounding means under NEC 350-5.
Adaptor—EMT to Flex
Dimensions (in.)
Cat. No. K.O. Size A B C
503-TB 1/2” - 1/2” 1-21/32 1-3/16 1-7/8
504 3/4” - 3/4” 1-25/32 1-7/16 2-1/8
505-TB 1” - 1” 2-1/32 2-1/16 2-5/8
Formed steel body with carefully round
bushing. The armour gripping saddle stays
open by itself when cable is being inserted.
Malleable iron.
For nonmetallic and armoured cable.
Tite-Bite ®fitting design holds flexible metal
cable firmly in place with a single screw rather
than two screws.
B
A
C (max)
CONFITMRO_EN_ALL.pdf 118 11/28/2011 11:05:40 AM
119
T&B Conduit Fittings
Armoured Cable and Flexible Metal Conduit Fittings
Combination Coupling
Size Dimension (in.)
Cat. No. Flex to EMT A B C
449C 3/8” - 1/2” 1-21/32 1-11/32 15/16
Cable opening: max. .656, min. .250
Anti-Short Bushing
Cat. No. Size
390 14-2, 14-3, 12-2
391 14-4, 12-3, 6-1, and 4-1
392 12-4, 10-2, 10-3 and 2-1
393 10-4, 8-2, 8-3, and 1-1
394 8-4, 6-2, 6-3, 4-2, 4-3, and 6-4
Colorized
Temperature Rating: 240°F
U.L. not applicable.
Strap
Cat. No. Bolt Hole Dia. Size
65C .265” 3/8” Flex
A one piece fitting that couples 3/8” flexible
metal conduit to 1/2” electrical metallic tubing
(EMT)
Anti-short bushings are made of smooth plastic,
and designed to protect conductor insulation from
rough edges of armoured cable and flexible metal
conduit.
C A B
15/16 15/16
1-21/32 1-11/32
CONFITMRO_EN_ALL.pdf 119 11/28/2011 11:05:41 AM
120
T&B Conduit Fittings
Nonmetallic Sheathed Cable Fittings
Specifications Nonmetallic (NM) Sheathed Cable
Ref. CEC Rule 12-500
Canadian Electrical Code 2009 Part I,
defines Nonmetallic Sheathed Cable as,
“A factory assembly of two or more
insulated conductors having an outer
sheath of moisture resistant, flame
retardant, nonmetallic material.”
Nonmetallic sheathed cable is
constructed of insulated conductors
(14 to 2 AWG copper), and an outer
nonmetallic sheath classified as Types
NMD90, NMW and NMWU.
Nonmetallic sheathed cable is
provided with bare bonding conductor.
Nonmetallic sheathed cable is rated for
90°C service with voltage limitation of
300 volts.
Type NMW and NMWU have a flame
retardant, moisture resistant sheath.
Type NMD90, NMW and NMWU
applications are described in Table 19
of CEC 2009 Part I.
Nonmetallic sheathed cable is
permitted by code to be used exposed
or concealed in one, two or multifamily
dwellings or other structures not
exceeding three floors. Use of Type
NMD90 cable is restricted to dry locations.
Nonmetallic sheathed cables are not
permitted to be used as a service
conductor. Nonmetallic sheathed cables
are also prohibited in hazardous locations.
NM cables need to be secured in
place by suitable means so as not to
injure the cable. Adequate protection
for cable is also required when run is
exposed, through joists or rafters,
through floors, in unfinished basements
and accessible attics.
NM cables shall be protected from
physical damage when it passes through
factory or field punched, cut or drilled
holes in metal members. A bushing or
grommet firmly secured in place is
recommended (CEC Rule 12-516).
Please refer to the following for further
details and complete information:
1. U.L. 719, ANSI C33.56 ..........Safety
Standards for Nonmetallic Sheathed
Cable
2. U.L. 514.................................Safety
Standards for Outlet Boxes and
Fittings
3. NEMA FB-1… ..Standards Publication:
Fittings and Supports for Conduit
and Cable Assemblies
4. CEC Section 12-500..............Wiring
methods (Nonmetallic Sheathed
Cable)
5. CSA C22.2 No. 48… .............Safety
Standards for Nonmetallic Sheathed
Cable
6. CSA C22.2 No. 18… .............Safety
Standards for Outlet Boxes,
Conduit Boxes and Fittings
Please Note
The excerpts and other material herein, whether relating to the Canadian Electrical
Code 2009 Part I, the Underwriters Laboratories, Inc. listing, to industry practice or
otherwise, is not intended to provide all relevant information required for use and
installation. Reference to original or primary source material and data is mandatory
before any application or use is made of the product.
CONFITMRO_EN_ALL.pdf 120 11/28/2011 11:05:41 AM
121
T&B Conduit Fittings
Nonmetallic Sheathed Cable Fittings
Suggested Specifications for Nonmetallic Sheathed Cable
Where nonmetallic sheathed cable
or flexible cord terminates into a
threaded or threadless opening,
terminating fittings used shall be
approved for the purpose by nationally
recognized laboratory, inspection agency
or product evaluation organization.
Terminating fittings shall be of
malleable iron, steel, or thermoplastic
construction designed to provide
adequate strain relief and positively
prevent damage to jacket or
conductor insulation such as series
3300 or 3302M manufactured by
Thomas & Betts.
Ferrous metal fittings shall be electro-zinc
plated inside and outside including
threads and bushed with a nylon
insulated throat.
Thermoplastic material used for
fitting construction shall be of
high impact strength suitable for
105°C/221°F service with a U.L.
flammability rating of 94V-1.
Where nonmetallic sheathed cable
passes through either factory or field
punched, cut or drilled holes
in metallic members, the cable
shall be protected by thermoplastic
bushing such as series 3210
manufactured by Thomas & Betts.
Bushing shall be firmly secured in
opening. Nylon bushed metallic
fittings such as Thomas & Betts series
1942 may be substituted
as required.
Series 3302M
Nonmetallic Sheathed Cable
and Flexible Cord Fittings
(Steel)
Series 3300
Nonmetallic Sheathed Cable
and Flexible Cord Fittings
(All Plastic)
Series 3210
Knockout Bushings
Series 1942
Insulated Nipples
CONFITMRO_EN_ALL.pdf 121 11/28/2011 11:05:41 AM
122
T&B Conduit Fittings
Nonmetallic Sheathed Cable Fittings
Nonmetallic Sheathed Cable & Flexible Cord Fittings (Steel)
Application
To connect nonmetallic sheathed
cable and flexible cord to a box or an
enclosure.
Features
Rugged all steel/malleable iron
construction (A).
Rounded cable clamp grip provides
superior mechanical holding power
without damaging conductor
insulation or outer jacket (B).
Clamp designed to cover body
opening for a neat and safe
installation.
Screws thread into clamp and not
body; screw heads are snug with
body and ends of screws do not
project beyond the body (C).
Insulator firmly secured in place
protects conductors and reduces
wire pulling effort; protects threads
from damage during handling (D).
Locknut designed to secure fitting
to a box or enclosure; will not vibrate
loose.
Standard Material
Body 1/2” thru 1” Steel; 1-1/4”
thru 2” Malleable Iron
Clamp 1/2” thru 1-1/4” Steel; 1-
1/4”
thru 2” Malleable Iron
Locknut All Steel
Insulator Thermoplastic
Standard Finish
All steel and malleable iron parts—
Electro Zinc Plated & Chromate
Coated
Range
Hub Size 1/2” thru 2” Hubs
provided with straight
pipe threads (NPS.)
Cable 2 #14 thru 4 #4 Type
NM
Cable Outside Diameter
0.250” to 1.150”
Conformity
U.L. 514B
CSA C22.2 No. 18.3
NFPA 70-2008 (ANSI)
NEMA FB-1
Federal Standard H-28 (Threads)
3302M Series
Nonmetallic Sheathed
Cable Fitting
Typical Installation
Typical Installation
(Flexible Cord)
Typical Installation
(NM-Sheathed Cable)
(D)
Locknut Box or
Enclosure Wall
(A)
(B)
(C)
CONFITMRO_EN_ALL.pdf 122 11/28/2011 11:05:41 AM
123
T&B Conduit Fittings
Nonmetallic Sheathed Cable Fittings
Steel or malleable iron.
Rounded cable grip and smooth bushing protect
the cable sheath and wire insulation. Since
saddle is threaded, screws do not travel or
extend beyond the fitting body as it is clamped
to the cable. An extra lip on the saddle closes
the unused part of the fitting opening.
Two-Screw Fittings
U.L. Listed & CSA Certified U.L. Listed & CSA
Cat. No. K.O. for the following Single (1) Certified for the following Dimensions (in.) Cable Opening
Noninsulated Insulated Size and Pairs of (2) NM & NMC Cable Service Entrance Cables A B C max. min.
3302* 3302M-C 1/2” (1) 2#14, 2#12, 2#10, 3#14, 2#12 thru 2#4, 3#12, 3#10 31/32” 1-3/8” 1” .590 .250
3#12, 3#10, (2) 2#14, 2#12
3303-C 3303M 3/4” (1) 2#8, 2#6, 3#8 2#8 thru 2#1/0, 3#8, 3#6, 1-1/4” 1-5/8” 1-3/16” .750 .530
(2) 2#12, 2#10, 2#8, 3#14 2#6 + #8 GND
(1) 3#8, 3#6, 3#4 2#1, 2#1/0, 3#6 thru 3#2,
3304 3304M 1” (2) 2#8, 3#10 2#4 + #6 GND, 2#3 + #5 1-15/32”1-7/8” 1-1/4” .990 .690
GND, 2#2 + #4 GND
(1) 3#8, 3#6, 3#4 3#2 thru 3#2/0, 2#1 + #3
3305 3305M 1-1/4” (2) 2#8, 2#6, 2#4, 3#8 GND, 2#1/0 + #2 GND, 1-15/16”2-7/32”1-9/32” 1.320 .850
2#2/0 + #1 GND
3306 3306M 1-1/2” (1) 3#4 3#3/0, 3#4/0, 2#3/0 + #1/0 2-5/32”2-21/32”1-5/8” 1.515 .930
GND, 2#4/0 + #2/0 GND
3307 3307M 2” Max. 1.98”, Min. 1.15”
3308 2-1/2” Max. 2.38”, Min. 1.5”
3309 3” Max. 2.88”, Min. 1.75” 2-25/32”3-5/16”1-29/32” 1.980 1.150
3310 3-1/2” Max. 3.38”, Min. 2.25”
3311 4” Max. 3.88”, Min. 2.5”
* U.L. Listed for use with rubber and thermoplastic flexible cords (both single and multiple cords and 2 oval cables).
U.L. Listed for multiple cords and cables.
CONFITMRO_EN_ALL.pdf 123 11/28/2011 11:05:41 AM
124
T&B Conduit Fittings
Nonmetallic Sheathed Cable Fittings
Application
To connect nonmetallic sheathed
cable and flexible cord to a box or an
enclosure.
Features
Provides strain relief by partially
deflecting cable (A); therefore:
(1) Fitting will not damage outer
covering or jacket of cable, or
conductor insulation; designed to
give safe trouble-free installation.
(2) Holding power and cable strain
relief are not effected by surface
finish of outer covering or cable
jacket.
(3) Fitting provides superior holding
power far in excess of listing
agency requirements.
Snap-in one piece design;
accommodates variation in knockout
dimensions, saves installation time
(B).
All high impact thermoplastic
construction provides:
(1) Insulated throat; conductors are
protected from abrasion.
(2) Improved dielectric strength, and
elimination of potential shorts.
(3) Corrosion resistance.
Wide range—reduces inventories
Fitting may be pre-installed in box
K.O., or on cable.
Standard Material
All high impact thermoplastic—U.L.
Class 94V-1 suitable for 105°C
application.
Standard Finish
As Molded
Listing/Certification
Cat. No. 3201, 3350 for factory
installation
Conformity
U.L. 514B
CSA C22.2 No.18.3
NFPA 70-2008 (ANSI)
Range
Knockout
Cat. No. Size Cable/ Cord Range
3300 1/2” 10-2, 12-2 & 14-2 type
NM Cable .125” to .300”
outside diameter cord
10-3, 12-3, 14-3, 10-
2, 12-2, 14-2 Type NM
Cable; also multiple
3201 & 1/2” (2) 12-2 and 14-2
3350 Type NM Cable;
.300” to .600” outside
diameter cord 8-3 and
6-3 type
3202 3/4” NM cables; also
Multiple (2) 14-3 and
10-2 Type NM Cable;
.500” to .850” outside
diameter cord
Box or
Enclosure Wall
(C)
Cable or Cord
(A)
(B)
1. Remove sheath from end
of cable (4” or more as
required). Insert cable through
fitting as shown (Cable under
button).
Nonmetallic Sheathed Cable and Flexible Cord Fittings
(All Plastic)
Typical Installation
3300 Series
4. Snap fitting into knockout
box. If desired this step
can be done prior to Step 1.
5. To remove from knockout box
depress ears.
6. To remove from cable cut
fitting as shown
2. Insert button into cavity.
3. With grooved pliers, or
parallel jaw type pliers
(commercially available)
squeeze button into cord or
wires as far into fitting body
as possible.
Note: It may be necessary to re-
adjust pliers to insure
button is properly installed.
CONFITMRO_EN_ALL.pdf 124 11/28/2011 11:05:41 AM
125
T&B Conduit Fittings
Nonmetallic Sheathed Cable Fittings
Figure 1
All Plastic Fitting for NM Cable and Flexible Cord
F
K.O. Dimensions (in.) Max. Thk.
Cat. No. Size Range Size Fig. A B C D E Enclosure H
3300 For use with 10-2, 12-2
and 14-2 NM cables;
18-2 and 18-3 SJ
and SJO cords and 1/2” 2 1-1/32 15/16 3/8 .880 .795 .080 5/16
x 9/16
18-2 SV, SVO, SJT
and SJTO cords, single
or multiple; cord capacity
.125-.300 diameter
3350 For use with 10-3, 12-3,
14-3, 10-2, 12-2,
4-2 NM cables; multiple
(2) 12-2 and 14-2 N 1/2” 1 1-11/32 1 7/16 .880 .795 .080
21/32 dia.
M cables; single and
multiple flexible cords
in wire range .300 in. to .600 in.
3202 For use with 8-3 and
6-3 NM cables; (2) 14-3,
14-2, 12-2 and 10-2 NM
cables; single and multiple 3/4” 1 1-1/2 1-5/16 7/16 1.100 1.005 .090 7/8 dia.
flexible cords in wire range
.500 in. to .850 in.
Temperature Rating: 105°C
Snap captive locking wedge into fitting’s cavity.
Press locking wedge into cavity which locks
onto cable.
H
Hole
Size
High impact thermoplastic. U.L. 94-V1.
Features push-in design. Captive locking wedge
secures cable with single squeeze of standard
electrician’s pliers. Provides excellent insulation,
strain-relief and high pull-out value.
Cat. No. 3201 is ideal for multiple flexible cords
and cable.
Figure 2
H
Hole Size
CONFITMRO_EN_ALL.pdf 125 11/28/2011 11:05:41 AM
126
T&B Conduit Fittings
Nonmetallic Sheathed Cable Fittings
Snap-in Fitting for Flexible Metal Conduit
Cat. No. Conduit Size K.O. Size A B C
100TB 3/8” 1/2” 27/32 1-13/32 1-31/32
100BP 3/8” 1/2” 27/32 1-13/32 1-31/32
Temperature Rating: 105°C
U.L. 94-V1
Swivel Tray Clamp
Conduit
Cat. No. Size
6209 1/2”-3/4”
6211 1”-1-1/4”
6214 1-1/2”-2”
6216 2-1/2”-3”
6218 3-1/2”-4”
Cable Tray Clamp
Conduit
Cat. No. Size
6210 1/2”-3/4”
6212 1”-1-1/4”
No locknut required. No special tools required.
High impact thermoplastic with steel insert.
Swivel cable tray clamps for aluminum and
steel trays with regular or reinforced flanges.
• Serrations and biting teeth on clamping
saddle provides a high quality bond between
conduit and clamp
• 1/2” to 6” sizes that can be clamped to any
position in a 90° arc
• Hardened steel screws bite into tray and
provide positive bond
• Malleable iron hub and steel u-bolt accepts
conduit from any angle
CONFITMRO_EN_ALL.pdf 126 11/28/2011 11:05:42 AM
127
T&B Conduit Fittings
Liquatite®Flexible Conduit Application Guide
High Listed for Low Accepts Std.
Conduit Metal Plastic*** Mech. Direct Halogen Fire Liquidtight Self EMI/RFI
Type Page Flexibility* Used** Used Strength Burial Free Hazard Fittings Extinguish Shielding Approval
TYPE-LT 129 B S P
pp.92-94
JIC
TYPE-LOR 130 B S P
pp.92-94
JIC
TYPE-EF 130 B S P
pp.92-94
JIC
TYPE-LA 131 C S P X X
pp.92-94
X
TYPE-CBLA 132 C S P X X
pp.92-94
X
TYPE-CSA 133 C S P X
pp.92-94
X
TYPE-ATLA 134 C S P X X
pp.92-94
X
TYPE-AT 135 B S P
pp.92-94
TYPE-ATX 135 B S T X
p.91
TYPE-ALT 136 C A P
pp.92-94
TYPE-CEA 137 C S U X X
pp.92-94
X
TYPE-ACEA 138 C A U X X
pp.92-94
X
TYPE-ZHLA 139 C S U X X X X
pp.92-94
X
TYPE-LAS 140 C S P X X
pp.92-94
XX
TYPE-EMS 141 C B P
pp.92-94
XX
TYPE-EMSP 141 C B P
pp.92-94
XX
TYPE-BR 142 C S X
pp.115-119
-3/8
TYPE-ABR 143 C A
pp.115-119
-3/8
TYPE-USL 144 B S
pp.115-119
TYPE-SL 144 A, B S
pp.115-119
TYPE-VJC 145 A, B S P
pp.115-119
TYPE-UG 145 C S
pp.115-119
TYPE-LNM-P 146 A P
p.102
X
TYPE-NMC 147 C P X X
pp.108-110
X
TYPE-NMT 147 A P X
pp.108-110
X
TYPE-CL 148 C N X X
p.150
X
TYPE-CLL 148 B N X
p.150
X
TYPE-CCG 149 B N X
p.150
TYPE-CLR 149 A N X
p.150
X
TYPE-CLFR 149 C N X X X
p.150
X
*** P=PVC
U=Pu
T=TPR
N=Nylon
* A=Continuous flexing
B= Small bend radius
C=Flexible
D=Pliable (static)
** S=Steel
A=Aluminum
B= Bronze
CONFITMRO_EN_ALL.pdf 127 11/28/2011 11:05:42 AM
128
T&B Conduit Fittings
Liquatite®Flexible Conduit Application Guide
Temperature Range
General
Chemical Resistance
Conduit °C -60 -40 -20 0 +50 +60 +75 +80 +90 +105 +150 See chart on page 156
Type °F -76 -40 -4 +32 +122 +140 +167 +176 +194 +221 +302 Oils Acids
TYPE-LT III I IIIIII X X
TYPE-LOR III I IIIIII X X
TYPE-EF III I IIIIII X X
TYPE-LA III I IIIIII X X
TYPE-CBLA III I IIIIII X X
TYPE-CSA III I IIIIII X X
TYPE-ATLA III I IIIIII X X
TYPE-AT III I IIIIII X X
TYPE-ATX III I IIIIII X
TYPE-ALT III I IIIIII X X
TYPE-CEA III I IIIIII X
TYPE-ACEA III I IIIIII X
TYPE-ZHLA III I IIIIII X
TYPE-LAS III I IIIIII X X
TYPE-EMS III I IIIIII X X
TYPE-EMSP III I IIIIII X X
TYPE-BR III I IIIIII
TYPE-ABR III I IIIIII
TYPE-USL III I IIIIII
TYPE-SL III I IIIIII
TYPE-VJC III I IIIIII X X
TYPE-UG III I IIIIII
TYPE-LNM-P III I IIIIII X X
TYPE-NMC III I IIIIII X X
TYPE-NMT III I IIIIII X X
TYPE-CL III I IIIIII X
TYPE-CLL III I IIIIII X
TYPE-CCG III I IIIIII X
TYPE-CLR III I IIIIII X
TYPE-CLFR III I IIIIII X
CONFITMRO_EN_ALL.pdf 128 11/28/2011 11:05:42 AM
129
T&B Conduit Fittings
Liquatite®Flexible Conduit Steel
Type LT
Carton Reel Reel
Trade Size Content* Content* Content* Inside Bend Radius Weight
(in.) Cat. No. (m) Cat No. (m) Cat No. (m) in. (mm) kg/30m
1/4 LT025-75 75 ---- 1.0 (25.4) 8
5/16 LT032-75 75 ---- 1.0 (25.4) 8
3/8 LT038-30 30 LT038-150 150 LT038-300 300 1.5 (38.1) 9
1/2 LT050-30 30 LT050-150 150 LT050-300 300 2.0 (50.8) 11
3/4 LT075-30 30 LT075-150 150 LT075-300 300 2.5 (63.5) 15
1LT100-30 30 LT100-120 120 -3.0 (76.2) 24
1-1/4 LT125-15 15 LT125-75 75 -- 3.5 (88.9) 31
1-1/2 LT150-15 15 LT150-45 45 -- 4.5 (114.3) 40
2LT200-15 15 LT200-30 30 -5.5 (139.7) 53
2-1/2 LT250-8 8LT250-80 80 -- 8.0 (203.2) 76
3-1/2 LT350-8 8LT350-50 50 -- 11.0 (279.4) 132
4LT400-8 8LT400-30 30 -- 12.0 (304.8) 156
5LT500-8 8---- 17.5 (444.5) 212
6LT600-8 8---- 22.5 (571.5) 259
See Chart on p.155 for dimensions and tolerances.
* See p.155 for label and packaging detail.
Typ e LT
A general purpose, flexible liquidtight
steel conduit designed for a variety of
installations requiring motion, vibration
and bending. It offers good mechanical
and moisture protection to enclosed
conductors.
Construction
The flexible inner core is made from a
spiral wound strip of corrosion resistant
plating steel. The 1/4 through 2 inch
trade sizes are squarelock formed and,
with the exception of the 1/4 inch size,
contain a nylon cord packing within the
convolutions.
The larger sizes are constructed with a
fully interlocked strip to add strength and to
prevent unraveling.
A flexible yet durable PVC jacket
is extruded over this core creating a liquid-
tight conduit resistant to most oils, acids
and vapors present in industrial
environments.
Refer to the Conduit Chemical
Resistance Chart beginning on p.158.
Applications
This conduit is used extensively in the
machine tool and other industrial
environments where flexibility is
necessary for installation and
maintenance or where vibration and
movement must be absorbed. The inherent
sunlight resistance of PVC enables this
product to be used in outdoor
applications. Compatible with
standard liquidtight fittings. The
construction of this conduit conforms to,
and is suitable for use with Sections 16 &
17.7 of the Electrical Standard for
Industrial Machinery (ANSI/NFPA-79).
Working Temperatures
-20°C to 80°C
Listing / Certification
JIC manufactured in accordance with
the dimensions and specifications as
outlined by the Joint Industrial Council
Standard for Mass Production Equipment
and Machine Tools.
Standard Colours
Machine tool grey and black. Other
colours available upon request. Part
numbers listed designate grey jacket.
Interlock
2-1/2 ” -6”
Squarelock with Filler
5/16” - 2”
JIC
CONFITMRO_EN_ALL.pdf 129 11/28/2011 11:05:43 AM
130
T&B Conduit Fittings
Liquatite®Flexible Conduit Steel
Type LOR
Type LOR
This product is offered as a non-UL oil-
resistant conduit that incorporates a
high quality PVC jacket.
Applications
The LOR is ideally used in situations
where a UL listing or CSA certification
is not a factor but where a flexible
conduit must withstand exposure to
many harsh chemicals, oils, UV, etc.
This conduit conforms to Section 17.7
of the Electrical Standard for Industrial
Machinery. (ANSI/NFPA-79) Compatible
with Standard Liquidtight Fittings.
Working Temperatures
-20°C to 60°C intermitting to 90°C
Standard Colours
Machine tool grey and black. Other
colours available upon request. Part
numbers listed designate grey jacket.
Note
For a UL listed version, consult your
Regional Sales Office for Type LA/LOR.
Trade Carton Carton Carton Inside
Size Content* Content* Content* Bend Radius Wt.
(in.) Cat. No. (m) Cat. No. (m) Cat. No. (m) in. (mm) Kg/30m
3/8 LOR038-30 30 LOR038-150 150 LOR038-300 300 2.0 (50.8) 19
1/2 LOR050-50 30 LOR050-150 150 LOR050-300 300 2.5 (63.5) 11
3/4 LOR075-30 30 LOR075-150 150 LOR075-300 300 3.0 (76.2) 15
1LOR100-30 30 LOR100-120 120 -- 4.0 (101.6) 24
1-1/4 LOR125-15 15 LOR125-60 60 -- 4.5 (114.3) 31
1-1/2 LOR150-15 15 ---- 5.5 (139.7) 40
2LOR200-15 15 ---- 7.0 (177.8) 53
2-1/2 LOR250-8 8---- 9.5 (241.3) 76
3LOR300-8 8---- 11.5 (292.1) 118
3-1/2 LOR350-8 8---- 13.0 (330.2) 132
4LOR400-8 8---- 14.0 (356.6) 156
5LOR500-8 8---- 20.0 (508.0) 221
6LOR600-8 8---- 22.5 (571.5) 259
See Chart on p.155 for dimensions and tolerances.
* See p.155 for label and packaging detail.
Type EF
Typ e EF
This flexible liquidtight conduit is a
competitive grade version of our Type LT. It
conforms to both the JIC standards for
dimensions and general construction,
and to Section 17.7 of the Electrical
Standard for Industrial Machinery
(ANSI/NFPA-79).
Construction
The flexible inner core is constructed
from a helically formed strip of corrosion
resistant steel. A liquidtight PVC jacket is
then extruded over the core.
Applications
General installations requiring some
movement and protection for contained
conductors. Forms a liquidtight system
when installed with standard fittings for
use indoors or out.
Working Temperatures
-20°C to 80°C
Standard Colour
Machine tool grey
Trade Carton Carton Carton Inside
Size Content* Content* Content* Bend Radius Wt.
(in.) Cat. No. (m) Cat. No. (m) Cat. No. (m) in. (mm) kg/30m
3/8 EF038-30 30 EF038-150 150 EF038-300 300 1.5 (38.1) 9
1/2 EF050-30 30 EF050-150 150 EF050-300 300 2.0 (50.8) 11
3/4 EF075-30 30 EF075-150 150 EF075-300 300 3.0 (63.5) 14
1EF100-30 30 EF100-120 120 -- 3.0 (76.2) 20
1-1/4 EF125-15 15 EF125-75 75 -- 3.5 (88.9) 25
1-1/2 EF150-15 15 EF150-45 45 -- 4.5 (114.3) 41
2EF200-15 15 EF200-30 30 -- 5.5 (139.7) 5
See Chart on p.155 for dimensions and tolerances.
* See p.155 for label and packaging detail.
JIC
130-135-e.pdf 1 1/23/2012 2:18:27 PM
131
T&B Conduit Fittings
Liquatite®Flexible Conduit Steel
Type LA
Type
LA
A flexible liquidtight steel conduit which
is both listed UL and certified CSA. It
offers outstanding protection against wet,
oily conditions and is permitted for use in
exposed or concealed locations.
Construction
The flexible inner core is made from
a spiral wound strip of heavy gauge,
corrosion resistant, hot-dipped galvanized
steel. The 3/8 through 1-1/4 inch trade
sizes are square lock formed and include
an integral bonding strip of copper that is
enclosed within the convolutions throug-
hout its entire length. The 1-1/2 through
4 inch trade sizes are designed with a fully
interlocked strip.
The liquidtight jacketing material is
of a high quality, rugged, flame retardant
flexible PVC compound which resists
oils, mild acids and exposure to sunlight.
For further information, refer to the
Conduit Chemical Resistance chart
beginning on p. 158.
Applications
This conduit is intended for installation
with Rule 12-1300 of Canadian
Electrical Code (CEC) Part I 2009.
The use of a separate bonding
conductor is mandatory in accordance
with CEC Rule 12-1306 for Ordinary
Locations.
The use of Liquidtight Flexible Conduit
with sign and Outline Lighting are in
accordance with CEC Rule 34-400 (2).
-
Listed and marked for direct burial
and in poured concrete.
-
For containment of 600-volt and
lower potential circuits
-
Sunlight resistant
Working Temperatures
-20°C to 60°C intermitting to 90°C
Listing / Certification
Listed. Conforms to UL Standard
ANSI/UL-360
for Liquidtight Flexible
Steel Conduit.
Certified. Conforms
to CSA 22.2
No. 56 for use per CEC C22.1
Section 12-1300.
Standard Colours
Machine tool grey, and black. Other
colours available upon request. Blue
is commonly used for computer room
installations. See TYPE CBLA on p.132.
Squarelock with filler
3/8” - 1-1/4”
Interlock
1-1/2” - 4”
Carton Reel Reel Inside Bend
Trade Size Content* Content* Content* Radius Weight
(in.) Cat. No. (m) Cat. No. (m) Cat. No. (m) in. (mm) kg/30m
3/8 LA038-30 30 LA038-150 150 LA038-300 300 2.0 (50.8) 13
1/2 LA050-30 30 LA050-150 150 LA050-300 300 3.0 (76.2) 15
3/4 LA075-30 30 LA075-150 150 LA075-300 300 4.2 (106.7) 24
1LA100-30 30 LA100-120 120 -- 5.5 (139.7) 37
1-1/4 LA125-15 15 LA125-60 60 -- 7.0 (177.8) 46
1-1/2 LA150-15 15 LA150-45 45 -- 4.5 (114.3) 47
2LA200-15 15 LA200-30 30 -- 6.0 (152.4) 66
2-1/2 LA250-8 8LA250-80 80 -- 8.0 (203.2) 87
3LA300-8 8LA300-50 50 -- 10.0 (254.0) 114
3-1/2 LA350-8 8LA350-50 50 -- 11.0 (279.4) 140
4LA400-8 8LA400-30 30 -- 12.0 (304.8) 154
See Chart on p.155 for dimensions and tolerances.
* See p.155 for label and packaging detail.
130-135-e.pdf 2 1/23/2012 2:18:28 PM
132
T&B Conduit Fittings
Liquatite®Flexible Conduit Steel
Type CBLA Computer Blue
Carton Reel Reel Inside Bend
Trade Size Content* Content* Content* Radius Wt.
(in.) Cat. No. (m) Cat. No. (m) Cat. No. (m) in. (mm) kg/30m
3/8 CBLA038-30 30 CBLA038-150 150 CBLA038-300 300 2.0 (50.8) 13
1/2 CBLA050-30 30 CBLA050-150 150 CBLA050-300 300 3.0 (76.2) 15
3/4 CBLA075-30 30 CBLA075-150 150 CBLA075-300 300 4.2 (106.7) 24
1CBLA100-30 30 CBLA100-120 120 -- 5.5 (139.7) 37
1-1/4 CBLA125-15 15 CBLA125-60 60 -- 7.0 (177.8) 46
1-1/2 CBLA150-15 15 CBLA150-45 45 -- 4.5 (114.3) 47
2CBLA200-15 15 CBLA200-30 30 -- 6.0 (152.4) 66
2-1/2 CBLA250-8 8CBLA250-80 80 -- 8.0 (203.2) 87
3CBLA300-8 8CBLA300-50 50 -- 10.0 (254.0) 114
3-1/2 CBLA350-8 8CBLA350-50 50 -- 11.0 (279.4) 140
4CBLA400-8 8CBLA400-30 30 -- 12.0 (304.8) 154
See Chart on p.155 for dimensions and tolerances.
* See p.155 for label and packaging detail.
Type CBLA
Computer Blue LA is a liquidtight
flexible steel conduit commonly used
for computer room installations. The
blue jacket colour easily identifies
circuitry for computer power wiring.
Construction
CBLA has a flexible inner core made
from a spiral wound strip of heavy
gauge, hot-dipped galvanized steel.
The 3/8 through 1-1/4 inch trade sizes
contain an integral bonding strip of
copper. The 1-1/2 and larger sizes are
designed with a fully interlocked strip.
The jacketing material is a rugged
flame retardant flexible blue PVC. For
installations which do not allow the use of
PVC, see TYPE ZHLA on P. 139.
Applications
Listed and marked for direct burial and
in poured concrete.
Working Temperatures
-20°C to 60°C
Listing / Certification
Listed. Conforms to UL
Standard ANSI/UL-360
for
Liquidtight Flexible Steel Conduit.
Certified. Conforms
to CSA 22.2
No. 56 for use per CEC C22.1
Section 12-1300.
130-135-e.pdf 3 1/23/2012 2:18:28 PM
133
T&B Conduit Fittings
Liquatite®Flexible Conduit Steel
Type CSA
Carton Reel Reel Inside Bend
Trade Size Content* Content* Content* Radius Weight
(in.) Cat. No. (m) Cat. No. (m) Cat. No. (m) in. (mm) kg/30m
3/8 CSA038-30 30 CSA038-150 150 CSA038-300 300 2.0 (50.8) 11
1/2 CSA050-30 30 CSA050-150 150 CSA050-300 300 3.0 (76.2) 16
3/4 CSA075-15 15 ----
3/4 CSA075-30 30 CSA075-150 150 CSA075-300 300 4.0 (101.6) 24
1CSA100-30 30 CSA100-120 --- 5.0 (127.0) 27
1-1/4 CSA125-15 15 CSA125-60 60 -- 6.2 (157.5) 39
1-1/2 CSA150-15 15 CSA150-45 45 -- 4.5 (114.3) 55
2CSA200-15 15 CSA200-30 30 -- 6.0 (152.4) 70
2-1/2 CSA250-8 8 -- -- 8.0 (203.2) 93
3CSA300-8 8---- 10.0 (254.0) 120
4CSA400-8 8 ---- 12.0 (304.8) 181
See Chart on p.155 for dimensions and tolerances.
* See p.155 for label and packaging detail.
Type CSA
This flexible liquidtight steel conduit is
certified CSA. Its design and function is
similar to that of type LA except that it
cannot be used as a ground return path
per CEC. It also offers a wider operating
temperature range.
Construction
The flexible inner core is made from a
spiral wound strip of heavy gauge,
corrosion resistant, hot-dipped
galvanized steel. The 3/8 through 1-1/4
inch trade sizes are cord packed.
The durable PVC flame retardant jacket
is designed for good flexibility and impact
resistance at low temperatures.
Applications
This conduit is intended for use according
to CEC as described in section 12-
1300 for dry, damp or wet locations
where flexibility is necessary.
This conduit is intended for installation
with Rule 12-1300 of Canadian
Electrical Code (CEC) Part I 2009.
The use of a separate bonding
conductor is mandatory in accordance
with CEC Rule 12-1306 for Ordinary
Locations.
The use of Liquidtight Flexible Conduit
with sign and Outline Lighting are in
accordance with CEC Rule 34-400 (2).
Working Temperatures
-40°C to 75°C
Listing / Certification
Certified. Conforms to CSA
Standard C22.2, No. 56. Flame Test
Rating FT-4 per CSA Standard
C22.2, No. 0.3.
Standard Colour
Black
130-135-e.pdf 4 1/23/2012 2:18:28 PM
134
T&B Conduit Fittings
Liquatite®Flexible Conduit Steel
Type ATLA All Temperature
Carton Reel Reel Inside Bend
Trade Size Content* Content* Content* Radius Wt.
(in.) Cat. No. (m) Cat. No. (m) Cat. No. (m) in. (mm) kg/30m
3/8 ATLA038-30 30 ATLA038-150 150 ATLA038-300 300 2.0 (50.8) 13
1/2 ATLA050-30 30 ATLA050-150 150 ATLA050-300 300 3.0 (76.2) 15
3/4 ATLA075-30 30 ATLA075-150 150 ATLA075-300 300 4.2 (106.7) 24
1ATLA100-30 30 ATLA100-120 120 -- 5.5 (139.7) 37
1-1/4 ATLA125-15 15 ATLA125-60 60 -- 7.0 (177.8) 46
1-1/2 ATLA150-15 15 ATLA150-45 45 -- 4.5 (114.3) 47
2ATLA200-15 15 ATLA200-30 30 -- 6.0 (152.4) 66
2-1/2 ATLA250-8** 8---- 8.0 (203.2) 87
3ATLA300-8** 8 ---- 10.0 (254.0) 114
3-1/2 ATLA350-8** 8 ---- 11.0 (279.4) 140
4ATLA400-8** 8---- 12.0 (304.8) 154
See Chart on p.155 for dimensions and tolerances.
* See p.155 for label and packaging detail.
** Not CSA Certified.
Type ATLA
A liquidtight flexible steel conduit
designed specifically for extreme hot or
cold environments. The flexible inner core
is identical to that found in Type LA. The
specially formulated PVC jacket remains
flexible at low temperatures and resists
ageing at elevated temperatures. It is listed
UL and certified CSA.
Construction
ATLA has a flexible inner core made
from a spiral wound strip of heavy
gauge, hot-dipped galvanized steel.
The 3/8 through 1-1/4 inch trade sizes
contain an integral bonding strip of
copper. The 1-1/2 and larger sizes are
designed with a fully interlocked strip.
The jacketing material is a rugged flame
retardant flexible PVC resistant to
weathering, UV, oils and many chemicals.
Refer to the Conduit Chemical
Resistance Guide beginning on p.158.
Applications
Designed to be used with high
temperature machine tool wiring. Ideal
for outdoor installations in cold
climates.
This conduit is intended for
installation with Rule 12-1300 of
Canadian Electrical Code (CEC) Part I
2002.
The use of a separate bonding
conductor is mandatory in accordance
with CEC Rule 12-1306 for Ordinary
Locations.
The use of Liquidtight Flexible Conduit
with sign and Outline Lighting are in
accordance with CEC Rule 34-400 (2).
- Listed and marked for direct burial
and in poured concrete.
-For containment of 600-volt and
lower potential circuits.
Working Temperatures
-55°C to 105°C Air / 60°C Wet / 70°C Oil
Listing / Certification
Listed. Conforms to UL Standard
ANSI/ UL-360 for Liquidtight
Flexible Steel Conduit.
Certified. Conforms to CSA 22.2
No. 56 for use per the CEC C22.1
Section 12-1300.
Conforms to the requirements of
Section 16 & 17.7 of the ANSI/NFPA-79
Electrical Standard for Industrial
Machinery.
Standard Colour
Machine tool grey
130-135-e.pdf 5 1/23/2012 2:18:28 PM
135
T&B Conduit Fittings
Liquatite®Flexible Conduit Steel
Type AT High and Low Temperatures
Typ e AT
A flexible steel conduit which uses a
jacketing material specifically designed
for hot or cold environments.
Applications
Type AT is well suited for exposure
to extreme climatic conditions. It is also
widely used on industrial process
equipment such as annealing ovens,
lumber kilns, foundries and refrigeration,
etc. The construction of this conduit
conforms to, and is suitable for use
with Sections 16 & 17.7 of the Electrical
Standard for Industrial Machinery
(ANSI/NFPA-79). Uses standard liquid-
tight fittings.
Working Temperatures
-55°C to 105°C intermitting to 120°C
Standard Colour
Machine tool grey
Note
For a UL listed and CSA certified
version, see TYPE ATLA on p. 134.
Trade Carton Carton Carton Inside
Size Content* Content* Content* Bend radius Wt.
(in.) Cat. No. (m) Cat. No. (m) Cat. No. (m) in. (mm) kg/30m
3/8 AT038-30 30 AT038-150 150 AT038-300 300 1.5 (38.1) 9
1/2 AT050-30 30 AT050-150 150 AT050-300 300 2.0 (50.8) 11
3/4 AT075-30 30 AT075-150 150 AT075-300 300 2.5 (63.5) 15
1AT100-30 30 AT100-120 120 -- 3.0 (76.2) 24
1-1/4 AT125-15 15 AT125-60 60 -- 3.5 (88.9) 31
1-1/2 AT150-15 15 AT150-45 45 -- 4.5 (114.3) 40
2AT200-15 15 AT200-30 30 -- 5.5 (139.7) 53
2-1/2 AT250-8 8---- 8.0 (203.2) 76
3AT300-8 8 ---- 10.0 (254.0) 118
3-1/2 AT350-8 8 ---- 11.0 (279.4) 132
4AT400-8 8 ---- 12.0 (304.8) 156
5AT500-8 8 ---- 17.5 (444.5) 221
6AT600-8 8 ---- 22.5 (571.5) 259
See Chart on p.155 for dimensions and tolerances.
* See p.155 for label and packaging detail.
Type ATX Extreme Temperature
Typ e ATX
A conduit designed to withstand an
extreme temperature range.
Construction
Utilizes the flexibility of our standard LT
core, coupled with the advantage of a
thermoplastic rubber jacket that is
virtually unaffected by temperature
extremes and contains no halogens. The
material has a UL 94-HB flammability
rating.
Applications
Used in situations where there are
concerns of resistance to temperature
exposure. These include heavy outdoor
equipment, boilers and furnaces, etc.
Refer to the Conduit Chemical
Resistance Guide beginning on p.158.
Working Temperatures
-60°C to 150°C intermitting to 165°C
Standard Colour
Black
Trade Carton Carton Carton Inside
Size Content* Content* Content* Bend radius Wt.
(in.) Cat. No. (m) Cat. No. (m) Cat. No. (m) in. (mm) kg/30m
3/8 ATX038-30 30 ATX038-150 150 ATX038-300 300 1.5 (38.1) 10
1/2 ATX050-30 30 ATX050-150 150 ATX050-300 300 2.0 (50.8) 12
3/4 ATX075-30 30 ATX075-150 150 ATX075-300 300 2.5 (63.5) 18
1ATX100-30 30 ATX100-120 120 -- 3.0 (76.2) 25
1-1/4 ATX125-15 15 ATX125-60 60 -- 3.5 (88.9) 33
1-1/2 ATX150-15 15 ATX150-45 45 -- 4.5 (114.3) 47
2ATX200-15 15 ATX200-30 30 -- 5.5 (139.7) 62
2-1/2 ATX250-8 8---- 8.0 (203.2) 85
3ATX300-8 8---- 10.0 (254.0) 111
4ATX400-8 8---- 12.0 (304.8) 151
See Chart on p.155 for dimensions and tolerances.
* See p.155 for label and packaging detail.
*New High Temperature Fittings available. Refer to p. 91.
130-135-e.pdf 6 1/23/2012 2:18:28 PM
136
T&B Conduit Fittings
Liquatite®Flexible Conduit Aluminum
Type ALT Lightweight Aluminum
Carton Reel Reel Inside
Trade Size Content* Content* Content* Bend Radius Wt.
(in.) Cat. No. (m) Cat No. (m) Cat No. (m) in. (mm) kg/30m
3/8 ALT038-30 30 ALT038-150 150 ALT038-300 300 2.0 (50.8) 5
1/2 ALT050-30 30 ALT050-150 150 ALT050-300 300 2.5 (63.5) 7
3/4 ALT075-30 30 ALT075-150 150 ALT075-300 300 3.0 (76.2) 9
1ALT100-30 30 ALT100-120 120 -- 4.0 (101.6) 13
1-1/4 ALT125-15 15 ALT125-60 60 -- 4.5 (114.3) 18
1-1/2 ALT150-15 15 ALT150-45 45 -- 5.5 (139.7) 25
2ALT200-15 15 ALT200-30 30 -- 7.0 (177.8) 33
2-1/2 ALT250-8 8---- 9.5 (241.3) 47
3ALT300-8 8 ---- 11.5 (292.1) 60
3-1/2 ALT350-8 8 ---- 13.0 (330.2) 74
4ALT400-8 8---- 14.0 (355.6) 81
5ALT500-8 8 ---- 20.0 (508.0) 114
6ALT600-8 8---- 22.5 (571.5) 143
See Chart on p.155 for dimensions and tolerances.
* See p.155 for label and packaging detail.
Type ALT
This version of Liquidtight Flexible
Conduit is similar to our standard type
LT but weighs considerably less due to
the use of an aluminum inner core
instead of steel.
Applications
Type ALT is often used where weight or
corrosive atmospheres are an issue. When
comparing identical trade sizes, Type ALT
weighs approximately 37% less than
type LT. Uses standard
liquidtight fittings.
Working Temperatures
-20°C to 80°C
Standard Colours
Machine tool grey and black. Other
colours available upon request. Part
numbers listed designate grey jacket.
CONFITMRO_EN_ALL.pdf 136 11/28/2011 11:05:44 AM
137
T&B Conduit Fittings
Liquatite®Flexible Conduit Steel
Type CEA Non-Halogen, Low Smoke, Flame Retardant
Carton Carton Minimum Inside
Trade Content* Content* Jacket Bend Radius Wt.
Size Cat. No. (m) Cat. No. (m) Thickness in. (mm) kg/30m
3/8 CEA038-30 30 CEA038-300 300 0.8 1.5 (38.1) 9
1/2 CEA050-30 30 CEA050-300 300 0.8 2.0 (50.8) 11
3/4 CEA075-30 30 CEA075-150 150 0.9 2.5 (63.5) 15
1CEA100-30 30 CEA100-120 120 0.9 3.0 (76.2) 24
1-1/4 CEA125-15 15 CEA125-60 60 0.9 3.5 (88.9) 31
1-1/2 CEA150-15 15 CEA150-45 45 1.0 4.5 (114.3) 40
2CEA200-15 15 CEA200-30 30 1.0 5.5 (139.7) 53
2-1/2 CEA250-8 8-- 1.3 8.0 (203.2) 76
3CEA300-8 8-- 1.3 10.0 (254.0) 118
4CEA400-8 8-- 1.5 12.0 (304.8) 156
5CEA500-8** 8-- 2.5 17.5 (444.5) 212
6CEA600-8** 8-- 2.5 22.5 (635.0) 259
See Chart on p.155 for dimensions and tolerances.
* See p.155 for label and packaging detail.
**Available on request.
Type ACEA also available (liquidtight flexible aluminum conduit).
Aluminum core weighs approximately one third less than steel core.
Type CEA Combustion & Flammability Properties
Combustion & Flammability Properties** Test Value
-Vertical Burn (Material) UL94 V-O Rating
No Flaming Drips
-Vertical Burn (Conduit) UL360 Pass
No Flaming Drips
-Oxygen Index % D2863 28.5
-Flame Spread Index ASTM E162 4.0
No Flaming Drips
-Flame Propagation ASTM C542 Pass
(NFPA-130) No Flaming Drips
-Smoke Generation (Flaming) ASTM E662 Ds 41 @ 1.5 min
(NFPA 258) Ds 94 @ 4.0 min
-Smoke Generation (Non-Flaming) ASTM E662 Ds 7 @ 1.5 min
(NFPA 258) Ds 45 @ 4.0 min
-Toxic Gas Generation BOMBARDIER SMP 800-C Pass
-Toxicity Index NES 713 3.9
**Test data is based on controlled laboratory conditions and does not necessarily reflect
performance in actual fire conditions. Additional product information available upon request.
Typ e CEA
This liquidtight flexible steel conduit is
designed for applications where safety
concerns exist regarding a material’s
reaction in a fire situation.
Construction
The flexible inner core of this product is
made from a galvanized steel strip. As
in type LT, this core contains string
packing between the helical
convolutions in trade sizes 3/8” through
2”. The specially formulated
thermoplastic polyurethane jacket has
excellent flame retardant characteristics
as well as low smoke and toxicity
generation characteristics. Acidic gases
such as hydrogen chloride, hydrogen
fluoride and hydrogen bromide are
virtually eliminated as products of
combustion.
Applications
This product is ideally suited for
installation in confined or enclosed
areas where construction materials
must generate very little smoke, and
have a low flame spread as well as low
toxic gas emissions in the event of fire.
Such applications include mass transit
vehicles where CEA is extensively
used for wiring harnesses within and
under passenger rail cars. Other
applications include use in underground
subway structures and tunnels.
Working Temperatures
-40°C to 80°C
Standard Colours
Grey and black. Other colours available
upon request. Part numbers listed
designate grey jacket.
CONFITMRO_EN_ALL.pdf 137 11/28/2011 11:05:44 AM
138
T&B Conduit Fittings
Liquatite®Flexible ConduitAluminum
Type ACEA Non-Halogen, Low Smoke, Flame Retardant
Type ACEA
This liquidtight flexible aluminum
conduit is designed for applications
where safety concerns exist regarding a
material’s reaction in a fire situation.
Min. Inside Bend Weight Carton Reel
Trade Jacket Thick. Radius Kilogram Length Length Length Length
Size Type (mm) (mm) 30 m (m) Cat. No. (m) Cat. No. (m) Cat. No. (m) Cat. No.
3/8 ACEA038 0.8 50.8 5 60 ACEA038-30 --300 ACEA038-300 --
1/2 ACEA050 0.8 63.5 7 30 ACEA050-30 30 -300 ACEA050-300 --
3/4 ACEA075 0.9 76.2 9 30 ACEA075-30 45 ACEA075-45 150 ACEA075-150 --
1ACEA100 0.9 101.6 13 30 ACEA100-30 - -120 ACEA100-120 --
1-1/4 ACEA125 0.9 114.3 18 15 ACEA125-15 --75 ACEA125-75 --
1-1/2 ACEA150 1.0 139.7 25 15 ACEA150-15 --45 ACEA150-45 --
2ACEA200 1.0 177.8 33 15 ACEA200-15 --30 ACEA200-30 --
2-1/2 ACEA250 1.3 241.3 47 8 ACEA250-8 ------
3ACEA300 1.3 330.2 60 8 ACEA300-8 ------
4ACEA400 1.5 355.6 87 8 ACEA400-8 ------
5ACEA500 2.5 508.0 114 8 ** ------
6ACEA600 2.5 571.5 143 8 ** --
----
See Chart on p.155 for dimensions and tolerances.
* See p.155 for label and packaging detail.
**Available on request.
Construction
The flexible inner core of this product is
made from an aluminum strip. As in
type CEA, this core contains string
packing between the helical
convolutions in trade sizes 3/8” through
1-1/4”. The specially formulated
thermoplastic polyurethane jacket has
excellent flame retardant characteristics
as well as low smoke and toxicity
generation characteristics. Acidic gases
such as hydrogen chloride, hydrogen
fluoride and hydrogen bromide are
virtually eliminated as products of
combustion.
Applications
This product is ideally suited for
installation in confined or enclosed
areas where construction materials
must generate very little smoke, and
have a low flame spread as well as low
toxic gas emissions in the event of fire.
Such applications include mass transit
vehicles where ACEA is extensively
used for wiring harnesses within and
under passenger rail cars. Other
applications include use in underground
subway structures and tunnels.
Working Temperatures
-40°C to 80°C
Standard Colours
Machine Tool Grey. Other colours
available upon request.
Note
A UL listed version is pending. Consult
factory for availability of type ZHLA.
Type ACEA Combustion & Flammability Properties
Combustion & Flammability Properties** Test Value
-Vertical Burn (Material) UL94 V-O Rating
No Flaming Drips
-Vertical Burn (Conduit) UL360 Pass
No Flaming Drips
-Oxygen Index % D2863 28.5
-Flame Spread Index ASTM E162 9.8
-Flame Propagation ASTM C542 Pass
(NFPA-130) No Flaming Drips
-Smoke Generation (Flaming) ASTM E662 Dm 103 (Corrected)
(NFPA 258) Ds 47 @ 4.0 min
-Smoke Generation (Non-Flaming) ASTM E662 Dm 91 (Corrected)
(NFPA 258) Ds 5 @ 1.5 min
-Toxic Gas Generation SMP 801 Pass
-Toxicity Index NES 713 3.9
**Test data is based on controlled laboratory conditions and does not necessarily reflect
performance in actual fire conditions. Additional product information available upon request.
CONFITMRO_EN_ALL.pdf 138 11/28/2011 11:05:44 AM
139
T&B Conduit Fittings
Liquatite®Flexible Conduit— Steel
Type ZHLA Non-Halogen, Low Smoke, Flame Retardant
Trade Carton Carton Carton Inside
Size Content* Content* Content* Bend Radius Wt.
(in.) Cat. No. (m) Cat. No. (m) Cat. No. (m) in. (mm) kg/30m
3/8 ZHLA038-30 30 ZHLA038-150 150 ZHLA038-300 300 2.0 (50.8) 13
1/2 ZHLA050-30 30 ZHLA050-150 150 ZHLA050-300 300 3.0 (76.2) 15
3/4 ZHLA075-30 30 ZHLA075-150 150 ZHLA075-300 300 4.2 (106.7) 24
1ZHLA100-30 30 ZHLA100-120 120 -- 5.5 (139.7) 37
1-1/4 ZHLA125-15 15 ZHLA125-60 60 -- 7.0 (177.8) 46
1-1/2 ZHLA150-15 15 ZHLA150-45 45 -- 4.5 (114.3) 47
2ZHLA200-15 15 ZHLA200-30 30 -- 6.0 (152.4) 66
2-1/2 ZHLA250-8 8---- 8.0 (203.2) 87
3ZHLA300-8 8 ---- 10.0 (254.0) 114
3-1/2 ZHLA350-8 8 ---- 11.0 (279.4) 140
4ZHLA400-8 8---- 12.0 (304.8) 154
See Chart on p.155 for dimensions and tolerances.
* See p.155 for label and packaging detail.
Type ZHLA Combustion & Flammability Properties
Combustion & Flammability Properties** Test Value
-Vertical Burn (Material) UL94 V-O Rating
No Flaming Drips
-Vertical Burn(Conduit) UL360 Pass
No Flaming Drips
-Oxygen Index % D2863 28.5
-Flame Spread Index ASTM E162 4.0
No Flaming Drips
-Flame Propagation ASTM C542 Pass
(NFPA-130) No Flaming Drips
-Smoke Generation (Flaming) ASTM E662 Ds 41 @ 1.5 min
(NFPA 258) Ds 94 @ 4.0 min
-Smoke Generation (Non-Flaming) ASTM E662 Ds 7 @ 1.5 min
(NFPA 258) Ds 45 @ min
-Toxic Gas Generation BOMBARDIER SMP 800-C Pass
-Toxicity Index NES 713 3.9
** Test data is based on controlled laboratory conditions and does not necessarily reflect
performance in actual fire conditions. Additional product information available upon request.
Type ZHLA
Non-halogen, low smoke and low flame
spread are what makes Type ZHLA a
proven choice for applications where
limiting toxic combustion materials is an
important issue. Since ZHLA is also UL
Listed, it is ideal for field installation in
confined, public areas such as subways,
tunnels, etc.
Construction
ZHLA has a flexible inner core made from
a spiral wound strip of heavy gauge, hot-
dipped galvanized steel. The 3/8 through
1-1/4 inch trade sizes contain
an integral bonding strip of copper. The 1-
1/2
inch
and larger sizes are designed with
a fully interlocked strip.
The specially formulated thermoplastic
black polyurethane jacket has excellent
flame resistance and low smoke and
toxicity generation characteristics. It is
also resistant to ozone, hydrocarbons,
moderate chemicals, oils and fuels. Refer
to the Conduit Chemical Resistance
Guide beginning on p. 156.
Applications
There are many situations and areas
where PVC is not allowed for electrical
construction. The jacketing material used
for ZHLA virtually eliminates the release of
acidic gases found in PVC products.
- Meets the requirements of
Bombardier SMP 800-C for Toxic
Gas Generation
- Meets the requirements of both
ASTM E162 for Flame Spread and
ASTM E662 for Smoke Generation.
- Listed and marked for direct burial
and in poured concrete.
- For containment of 600-volt and
lower potential circuits.
- Sunlight resistant
Working Temperatures
-40°C to 80°C Air / 60°C Wet / 70°C Oil
Listing / Certification
Listed. Conforms to UL Standard
ANSI/ UL-360 for Liquidtight Flexible
Steel Conduit.
Standard Colour
Black
CONFITMRO_EN_ALL.pdf 139 11/28/2011 11:05:45 AM
140
T&B Conduit Fittings
Liquatite®Flexible Conduit Shielding
Type LAS
Trade Carton Carton Inside
Size Content* Content* Bend Radius Wt.
(in.) Cat. No. (m) Cat. No. (m) in. (mm) kg/30m
3/8 LAS038-30 30 LAS038-150 150 2.0 (50.8) 13
1/2 LAS050-30 30 LAS050-150 150 3.0 (76.2) 15
3/4 LAS075-30 30 LAS075-150 150 4.2 (106.7) 24
1LAS100-30 30 LAS100-120 120 5.5 (139.7) 37
See Chart on p.155 for dimensions and tolerances.
* See p.155 for label and packaging detail.
Type LAS
Type LAS is identical to standard UL Listed
liquidtight flexible steel conduit but is
augmented with a tinned copper shielding
braid located over the inner steel core and
under its protective PVC jacket. The braid
offers a minimum of 90% coverage
resulting in a shielding effectiveness range
from 126 dB @ 1 MHz to 66 dB @ 1 GHz.
Applications
PVC jacket is resistant to a wide variety of
oils, acids, alkalines and ultraviolet light.
Working Temperatures
-20°C to 60°C
Listing / Certifications
Listed. Conforms to UL360 for
liquidtight flexible steel conduit.
Standard Colours
Black. Other colours and jacketing
materials available. Consult your Regional
Sales Office for details.
Thomas & Betts offers three types of
flexible liquidtight conduits designed for
wiring applications requiring shielding
effectiveness from Electro-Magnetic
and Radio Frequency Interference
(EMI/RFI).
This series of shielding conduits consists
of three configurations: Type LAS, Type
EMS and Type EMSP.
These conduits are used to protect
sensitive electronic circuits such as
communications, radar, and data
transmission from outside interference or
“noise”. The reverse situation is also
an issue. Today’s Original Equipment
Manufacturers (OEMs) are finding that, if
they wish to ship electrical equipment into
the European community, they may need
to be in compliance with recently
developed CE standards which reduce
the allowable amount of EMI/RFI
emissions from electrical apparatus.
All three are designed to accept
industry standard liquidtight fittings and
address the problems of assembly and
grounding. Fittings of this type include a
grounding ferrule which contacts the
internal metallic material of
the conduit and the fitting body. This
produces a direct shield-to-drain or
ground, simply by tightening the fitting.
The graph below depicts the shielding
effectiveness (attenuation in dBs) of all
three types. The dotted line shows
a comparison to standard unshielded
liquidtight flexible conduit, Type LA. The
spectrum of test frequency is from 1 MHz
to 10 MHz Electric Field, to 100 MHz to
1 GHz (1000 MHz) Planewave Field.
Tests were performed per MIL-STD-285
on 1/2inch trade size conduit.
Shielding Effectiveness
1 MHz 10 MHz 100 MHz 450 MHz 1 GHz
EMSP 127 130 136 116 118
EMS 126 122 131 98 97
LAS 126 98 75 76 66
LA 110 80 53 63 51
ATTENUATION (dB)
CONFITMRO_EN_ALL.pdf 140 11/28/2011 11:05:45 AM
141
T&B Conduit Fittings
Liquatite®Flexible Conduit— Shielding
Type EMS
Type EMS
Type EMS has an inner core that is
made from a fully interlocked bronze
strip. Even though it does not contain a
braided shield, it offers a shielding
effectiveness from 126 dB @ 1 MHz to
nearly 100 dB @ 1 GHz.
Working Temperatures
-55°C to 105°C
Standard Colour
Grey. Other colours and jacketing
materials available.
Consult your Regional
Sales Office for details.
Trade Carton Carton Inside
Size Content* Content* Bend Radius Wt.
(in.) Cat. No. (m) Cat. No. (m) in. (mm) kg/30m
3/8 EMS038-30 30 EMS038-150 150 3.0 (76.2) 12
1/2 EMS050-30 30 EMS050-150 150 3.0 (76.2) 16
3/4 EMS075-30 30 EMS075-150 150 4.0 (101.6) 20
1EMS100-30 30 EMS100-120 120 4.0 (101.6) 39
1-1/4 EMS125-15 15 EMS125-60 60 4.5 (114.3) 46
1-1/2 EMS150-15 15 EMS150-45 45 7.0 (177.8) 64
2EMS200-15 15 EMS200-30 30 9.5 (241.3) 82
2-1/2 EMS250-8 8-- 12.0 (304.8) 105
3EMS300-8 8 -- 13.5 (342.9) 145
4EMS400-8 8 -- 17.0 (431.8) 176
See Chart on p.155 for dimensions and tolerances.
* See p.155 for label and packaging detail.
Type EMSP
Type EMSP is a hybrid of LAS and EMS. It
utilizes the same bronze core and PVC
jacket as EMS but gets further screening
protection from a tinned copper braid as
found in the LAS product. Its range of
shielding effectiveness is from 126 dB @
1 MHz to 120 dB @ 1 GHz.
Trade Carton Carton Inside
Size Content* Content* Bend Radius Wt.
(in.) Cat. No. (m) Cat. No. (m) in. (mm) kg/30m
3/8 EMSP038-30 30 EMSP038-150 150 3.0 (76.2) 12
1/2 EMSP050-30 30 EMSP050-150 150 3.0 (76.2) 16
3/4 EMSP075-30 30 EMSP075-150 150 4.0 (101.6) 20
1EMSP100-30 30 EMSP100-120 120 4.0 (101.6) 39
See Chart on p.155 for dimensions and tolerances.
* See p.155 for label and packaging detail.
INTERLOCK
Type EMSP
CONFITMRO_EN_ALL.pdf 141 11/28/2011 11:05:45 AM
Type BR
Min.Trade Coil Coil Coil Coil Coil Inside
Size Content Content Content Content Content Bend Radius
Wt.
(in.) Cat. No. (m) Cat. No. (m) Cat. No. (m) Cat. No. (m) Cat. No. (m) in. (mm) kg/30m
3/8 BR038-8* 8BR038-15* 15 BR038-30* 30 BR038-75* 75 BR038-300* 300 2.0 (50.8) 18
1/2 BR050-8 8BR050-15 15 BR050-30 30 --BR050-300 300 3.0 (76.2) 13
3/4 BR075-8 8BR075-15 15 BR075-30 30 --BR075-150 150 4.0 (101.6) 15
1--BR100-15 15 ----BR100-120 120 5.0 (127.0) 24
1-1/4 --BR125-15 15 ----BR125-120 120 6.2 (157.5) 29
1-1/2 --BR150-8 8----BR150-90 90 7.5 (190.5) 36
2--BR200-8 8----BR200-45 45 10.0 (254.0) 45
2-1/2 --BR250-8 8------ 12.5 (317.5) 68
3--BR300-8 8------ 15.0 (381.0) 82
3-1/2 --BR350-8 8------ 17.5 (444.5) 100
4--BR400-8 8------ 20.0 (508.0) 122
* CSA Certified.
Type BR
This non-jacketed flexible steel conduit has
many universal wiring applications. It is often
referred to as “Greenfield” or “Reduced
Wall Flex”.
Construction
Type BR is formed from high corrosion
resistant hot-dipped galvanized steel. Its
profile and helical shape allow it to
withstand impact and crushing forces.
Applications
General Use:
In accordance with CEC Rule 12-1002 (1)
the flexible metal conduit is permitted in or
on buildings of either combustible or non-
combustible constructions.
Restriction and Exception:
CEC Rule 12-1004 (a) states:“12 (
3/8
)
trade size flexible metal conduit shall be
permitted to be used for runs of not more
than 1.5 m (5 ft) for the connection
of equipment.”
and CEC Rule 12-1004 (b) states:“12 (
3/8
)
trade size liquidtight flexible conduit may be
used as permitted by this code.”
Securements with straps:
CEC Rule 12-1010 (3) states: “When
flexible metal conduit is installed, it shall be
secured at intervals not exceeding 1.5 m (5
ft) and within 300 mm (12 in.) on each side of
every outlet box or fitting except where
flexible metal conduit is fished and except for
lengths of not over 900 mm (3 ft) at terminals
where flexibility is necessary.”
Conductor fill:
CEC Rule 12-1014 defines the maximum
number of conductor, the CEC Tables 6
provides the maximum number of
conductors of one size in trade sizes of
conduit,CEC Table 8 provides the maximum
allowable per cent conduit fill, and CEC Table
9 provides the cross-sectional areas of
conduit.
Specific Use and applications:
Elevators, Hoistways, in accordance with
CEC Rules 38-021 (1) (a) (1) and 38-0221 (1)
(a) (iv)
Elevators, Cars, in accordance with CEC
Rules 38-021 (1) (b) (v)
Elevators, Within Machine Rooms, Control
Rooms and Machinery Spaces and Control
Spaces, in accordance with CEC Rule
38-021 (1) (c) (1)
Elevators, Conterweights, in accordance
with CEC Rule 38-021 (1) (d)
EScalators, in accordance with CEC Rule
38-021 (2)
Lifts for persons with physical disabilities, in
accordance with CEC Rule 38-021 (3)
Theater installation, in accordance with CEC
Rule 44-102 (1)
Listing/ Certification
Listed. (sizes 3/8 through 3 in.).
Conforms to UL Standard ANSI/UL-1
for Flexible Metal Conduit.
Certified. (3/8 inch size only).
Conforms to CSA 22.2 No. 56 for use
per CEC C22.1 Section 12-1000.
Meets Federal Specification WW-C-566c
Type II
Flexible metal conduit is also per mitted
for use on industrial machinery where
temperatures exceed the limits of
liquidtight flexible conduit. (ANSI/NFPA-79)
Section 16.3.4 (exception) and Section
17.9.
Trade Inner Diameter Outer Diameter
Size Min. Max. Min. Max.
(in.) Cat. No. in. (mm) in. (mm) in. (mm) in. (mm)
3/8 BR038* 0.375 (9.5) 0.393 (10.0) 0.560 (14.2) 0.610 (15.5)
1/2 BR050 0.625 (15.9) 0.645 (16.4) 0.860 (21.8) 0.920 (23.4)
3/4 BR075 0.812 (20.6) 0.835 (21.2) 1.045 (26.5) 1.105 (28.1)
1BR100 1.000 (25.4) 1.040 (26.4) 1.300 (33.0) 1.380 (35.1)
1-1/4 BR125 1.250 (31.8) 1.300 (33.0) 1.550 (39.4) 1.630 (41.4)
1-1/2 BR150 1.500 (38.1) 1.575 (40.0) 1.850 (47.0) 1.950 (49.5)
2BR200 2.000 (50.8) 2.080 (52.8) 2.350 (59.7) 2.454 (62.3)
2-1/2 BR250 2.500 (63.5) 2.700 (68.6) 2.860 (72.6) 3.060 (77.7)
3BR300 3.000 (76.2) 3.200 (81.3) 3.360 (85.3) 3.560 (90.4)
3-1/2 BR350 3.500 (88.9) - - 3.860 (98.0) 4.060 (103.1)
4BR400 4.000 (101.6) - - 4.360 (110.7) 4.560 (115.8)
* CSA Certified.
Types BR and ABR Strip Profile
142
T&B Conduit Fittings
Liquatite®Flexible Conduit Steel
CONFITMRO_EN_ALL.pdf 142 11/28/2011 11:05:45 AM
143
T&B Conduit Fittings
Liquatite®Flexible Conduit — Aluminum
Type ABR
Trade Coil Coil Coil Reel
Size Length Length Length Content* Wt.
(in.) Cat. No. (m) Cat. No. (m) Cat. No. (m) Cat. No. (m) kg/30m
-- - - -ABR716-30 30 ABR716-300 300 -
3/8 ABR038-88ABR038-1515 ABR038-3030 ABR038-300300 7.0
1/2 ABR050-8 8ABR050-15 15 ABR050-30 30 ABR050-300 300 9.5
3/4 ABR075-8 8ABR075-15 15 ABR075-30 30 ABR075-150 150 13.5
1- -ABR100-15 15 - - ABR100-120 120 24.0
1-1/4 - - ABR125-15 15 - - ABR125-120 120 31.0
1-1/2 - - ABR150-8 8 - - ABR150-90 90 47.0
2- -ABR200-8 8 - - ABR200-45 45 67.0
2-1/2 - - ABR250-8 8-- -92.0
3- -ABR300-8 8 - - - 107.0
3-1/2 - - ABR350-8 8 - - - 122.0
4- -ABR400-8 8 - - - 142.0
See Chart on p.155 for dimensions and tolerances.
* See p.155 for label and packaging detail.
Note: Dimensions and Bend Radii are identical to Type BR, p. 140.
† CSA Certified.
trade size liquidtight flexible conduit may be
used as permitted by this code.”
Securements with straps:
CEC Rule 12-1010 (3) states: “When
flexible metal conduit is installed, it shall be
secured at intervals not exceeding 1.5 m (5
ft) and within 300 mm (12 in.) on each side of
every outlet box or fitting except where
flexible metal conduit is fished and except for
lengths of not over 900 mm (3 ft) at terminals
where flexibility is necessary.”
Conductor fill:
CEC Rule 12-1014 defines the maximum
number of conductor, the CEC Tables 6
provides the maximum number of
conductors of one size in trade sizes of
conduit, CEC Table 8 provides the
maximum allowable per cent conduit fill,
and CEC Table 9 provides the cross-
sectional areas of conduit.
Applications: refer to Type BR, p. 142.
Listing/ Certification
Listed. (sizes 3/8 through 3 in.).
Conforms to UL Standard ANSI/UL-1
for Flexible Metal Conduit.
Certified. (3/8 inch size only).
Conforms to CSA 22.2 No. 56 for
use per CEC C22.1 Section 12-1300.
Meets Federal Specification WW-C-566c
Type II
Type ABR
This non-jacketed flexible aluminum
conduit has many universal wiring
applications. It is often referred to as
“Greenfield” or “Reduced Wall Flex”.
Construction
Type ABR is formed using a high strength
aluminum alloy strip. The result is a conduit
with similar characteristics to those of type
BR steel but at about 1/3the weight.
Applications
General Use:
In accordance with CEC Rule 12-1002 (1)
the flexible metal conduit is permitted in or
on buildings of either combustible or non-
combustible constructions.
Restriction and Exception:
CEC Rule 12-1004 (a) states:“12 (
3/8
) trade
size flexible metal conduit shall be permitted
to be used for runs of not more than 1.5 m
(5 ft) for the connection of equipment.”
and CEC Rule 12-1004 (b) states:“12 (3/8)
CSA Internal Outer Inside WT. Coil
Trade Metric T&B Diameter (in.) Diameter (in.) Bend Lbs. per Lenght
Size Desig. Type Min. Max. Min. Max. Radius 100 Ft. Mtr.
3/8 12 ABRH038 0.375 0.393 0.560 0.610 2 7 30, 150, 300
7/16 14 ABRH716 0.437 0.457 - 0.675 2.25 8 30, 150, 300
1/2 16 ABRH050 0.625 0.645 0.860 0.920 3 16 30, 150, 300
3/4 21 ABRH075 0.812 0.835 1.045 1.105 4 18 30, 150, 300
127ABRH100 1.000 1.040 1.300 1.380 5 35 15, 120
1-1/4 35 ABRH125 1.250 1.300 1.550 1.630 6.2 43 15, 120
1-1/2 41 ABRH150 1.500 1.575 1.850 1.950 7.5 55 8, 15, 30
253ABRH200 2.000 2.080 2.350 2.454 10 73 8, 15
2-1/2 63 ABRH250 2.500 2.700 2.860 3.060 12.5 90 8, 15
378ABRH300 3.000 3.200 3.360 3.560 15 107 8, 15
4 103 ABRH400 4.000 - 4.360 4.560 20 142 8, 15
Type ABRH
TYPE - ABRH
This non-jacketed flexible aluminum
conduit has many universal wiring
applications.
Construction
Type ABRH is formed from a heavy
gauge aluminum strip. Its profile and
helical shape allow it to withstand
substantial impact and crushing forces.
Applications
This conduit is intended as a metal
raceway for wires and cable where CSA
Certification is required. Suitable for use
with connectors intended for “FMC
(Flexible Metal Conduit).
Certified
File # LL 18858 Conforms to CSA
22.2 No. 56 for use per the Canadian
Electrical Code C22.1 Section 12-1300.
CONFITMRO_EN_ALL.pdf 143 11/28/2011 11:05:46 AM
144
T&B Conduit Fittings
Liquatite®Flexible Conduit — Steel
Type SL
Coil
Inside Diameter Outside Diameter Min. Inside
Trade Size Content
M
in.
M
ax.
M
in.
M
ax.
Bend Radius Wt.
(in.) (mm) Cat. No. (m) in. (mm) in. (mm) in. (mm) in. (mm) (in) (mm) kg/30m
--SL316-75 75 0.172 (4.35) 0.202 (5.13) 0.280 (7.11) 0.310 (7.87) 0.75 (19.5) 2
--SL140-75 75 0.235 (5.97) 0.265 (6.73) 0.328 (8.33) 0.358 (9.09) 0.75 (19.5) 3
5/16 - SL516-75 75 0.297 (7.54) 0.327 (8.31) 0.391 (9.93) 0.421 (10.69) 0.75 (19.5) 3
--SL380-75 75 0.360 (9.14) 0.390 (9.91) 0.485 (12.32) 0.515 (13.08) 1.00 (25.4) 4
--SL716-75 75 0.422 (10.72) 0.452 (11.48) 0.547 (13.89) 0.577 (14.66) 1.00 (25.4) 4
3/8 16 SL038-75 75 0.492 (12.50) 0.512 (13.00) 0.617 (15.67) 0.637 (16.18) 1.00 (25.4) 5
--SL916-45 45 0.547 (13.89) 0.577 (14.66) 0.672 (17.07) 0.702 (17.83) 1.25 (31.8) 5
1/2 - SL050-45 45 0.622 (15.80) 0.642 (16.31) 0.747 (18.97) 0.767 (19.48) 1.50 (38.1) 7
-20SL050M-45 45 0.650 (16.51) 0.670 (17.01) 0.775 (19.69) 0.795 (20.19) 1.50 (38.1) 7
--SL340-45 45 0.735 (18.67) 0.765 (19.43) 0.865 (21.97) 0.895 (22.73) 1.50 (38.1) 8
3/4 25 SL075-30 30 0.827 (21.00) 0.847 (21.51) 0.957 (24.31) 0.977 (24.82) 2.00 (50.8) 8
1-SL100-15 15 1.041 (26.44) 1.066 (27.07) 1.181 (30.00) 1.206 (30.63) 2.00 (50.8) 9
-32SL100M-15 15 1.102 (27.99) 1.122 (28.50) 1.242 (31.55) 1.262 (32.05) 2.00 (50.8) -
Type SL
This “extra-flexible” product, available in the
smaller diameters, is designed for tightspot
installation and where continuous flexing is
required of a steel wound hose.
Construction
Type SL is helically wound from a formed
strip of Electro-Galvanized steel. It is sized to
be used with a variety of set-screw and
clamp type fittings.
Applications
Offers good mechanical protection to wiring
in a variety of O.E.M. applications.
Squarelock
Type USL
This extra-flexible steel conduit is recognized
UL and CSA for use within listed and certified
assemblies.
Construction
Helically formed from hot-dipped galvanized
steel, type USL offers good corrosion
resistance and provides excellent
mechanical protection to enclosed circuits.
Applications
This product is intended as a factory
installed component of various
assemblies. Typical uses include modular
office partitions, showcase lighting, range
tops and other appliances.
Listing / Certification
UL Recognized.
Inner Dia. Outer Dia. Coil Min. Inside
Min. Max. Min. Max. Contents Bend Radius Wt.
Cat. No. in. (mm) in. (mm) in. (mm) in. (mm) Cat. No. (m) in. (mm) kg/30m
USL516 0.297(7.54) 0.327(8.30) 0.457(11.60) 0.487(12.37) USL516-75 75 1.25 (31.75) 5
USL380 0.360(9.14) 0.390(9.91) 0.520(13.20) 0.550(13.97) USL380-75 75 1.25 (31.75) 6
USL716 0.422(10.7) 0.452(11.48) 0.582(14.78) 0.612(15.54) USL716-75 75 1.50 (38.10) 7
USL120 0.485(12.3) 0.515(13.08) 0.645(15.86) 0.675(17.15) USL120-75 75 1.50 (38.10) 8
USL916 0.557(14.1) 0.577(14.65) 0.707(17.96) 0.737(18.72) USL916-75 75 1.50 (38.10) 9
Type USL
Squarelock Type USL
CONFITMRO_EN_ALL.pdf 144 11/28/2011 11:05:46 AM
145
T&B Conduit Fittings
Liquatite®Flexible Conduit Steel
Type VJC with PVC Jacket
Type VJC
Vacuum jacketed steel conduit for high-flex
installations.
Construction
A unique vacuum extrusion process allows
this product to have a thin PVC jacket which
does not restrict the great flexibility
characteristics of the inner core. The core
material is the same as type SL. VJC is
designed with dimensions that will accept
standard liquidtight fittings.
Applications
VJC is suitable for use in both static
applications where a tight bend diameter is
needed and in dynamic use such as
machining centers and robotics.
Working Temperatures
-20°C to 80°C
Standard Colour
Black. Other colours available upon
request. Consult your Regional Sales
Office for details.
Outside Dia. Internal
Trade Carton Over Jacket Bend radius
Size Content* Min. Max. Static Dynamic Wt.
(in.) Cat. No. (m) in. (mm) in. (mm) in. (mm) in. (mm) kg/30m
3/8 VJC038-30 30 0.647 (16.43) 0.677 (17.20) 1.0 (25.4) 5 (127.0) 5
1/2 VJC050-30 30 0.777 (19.74) 0.807 (20.50) 1.5 (38.1) 6 (152.4) 7
-VJC050M-30 30 0.805 (20.45) 0.835 (21.21) 1.5 (38.1) 6 (152.4) 7
3/4 VJC075-30 30 0.987 (25.07) 1.017 (25.83) 2.0 (51.0) 10 (254.0) 9
1VJC100-30 30 0.221 (5.61) 1.246 (31.65) 3.0 (76.0) 10 (254.0) 11
-VJC100M-30 30 1.272 (32.31) 1.302 (33.07) 3.0 (76.0) 10 (254.0) -
* Reels available. Consult factory.
Type UG
A fully-interlocked flexible steel conduit
designed for high strength in “tight-spot”
installations.
Construction
This conduit is manufactured from a bright
tin plated steel strip which is fully
interlocked at the edges to produce a
strong, yet flexible product. The interlock
feature does not allow the conduit to
unravel if twisted and permits the conduit
to retain it’s shape when bent. This
lightweight product is compatible with
many set-screw and clamp type fittings.
Applications
The bright appearance of the finished
product lends itself to installations
where the conduit may be visible after
final assembly.
Coil Inside diameter Outside DiameterMin. Inside
Content Min. Max. Min. Max. Bend Radius Wt.
Cat. No. (m) in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) kg/30m
UG380-15 15 0.443(11.25) 0.473(12.01) 0.563(14.30) 0.593(15.06) 2.5 (63.5) 7
UG120-15 15 0.755(19.18) 0.785(19.94) 0.875(22.23) 0.905(22.99) 3.0 (76.2) 10
UG340-15 15 0.943(23.95) 0.973(24.71) 1.063(28.70) 1.093(27.76) 3.5 (89.0) 14
UG100-15 15 1.208(30.68) 1.238(31.45) 1.328(33.73) 1.358(34.50) 4.5 (114.3) 16
UG125-15 15 1.485(37.72) 1.515(38.48) 1.578(40.08) 1.608(40.84) 5.5 (139.7) 23
UG150-15 15 1.735(44.07) 1.765(44.83) 1.843(46.81) 1.873(47.57) 6.5 (165.1) 27
UG200-15 15 2.235(56.77) 2.265(57.53) 2.390(60.71) 2.420(61.47) 8.5 (216.0) 36
UG250-15 15 2.735(69.47) 2.765(70.23) 2.937(74.60) 2.967(75.36) 10.5 (267.0) 39
UG300-15 15 3.36085.34) 3.390(86.11) 3.438(87.33) 3.468(88.09) 13.0 (330.2) 48
Note: Trade sizes do not apply to Type UG.
Type UG
Interlock
CONFITMRO_EN_ALL.pdf 145 11/28/2011 11:05:46 AM
Type LNM-P
Trade Carton Reel Reel Inside Dia.
Outside Dia.
Inside
Size
Content Content Content Min. Max. Min. Max. Bend Radius Wt.
(in.) Cat. No. (m) Cat. No. (m) Cat. No. (m) in. (mm) in. (mm) in. (mm) in. (mm) in. (mm) kg/30m
3/8 LNMP038-75 75 LNMP038-150 150 LNMP038-300 300 0.485(12.32) 0.505(12.83) 0.755(19.18) 0.775(19.69) 2.5 (63.5) 7
1/2 LNMP050-60 60 LNMP050-150 150 LNMP050-300 300 0.620(5.08) 0.640(16.26) 0.910(23.11) 0.930(23.62) 3.0 (76.2) 10
3/4 LNMP075-50 50 LNMP075-150 150 -- 0.815(20.70) 0.835(21.21) 1.150(29.21) 1.170(29.72) 4.0 (101.6) 14
1LNMP100-30 30 LNMP100-120 120 -- 1.030(26.16) 1.055(26.80) 1.415(35.94) 1.440(36.58) 6.0 (152.4) 19
1-1/4 LNMP125-30 30 LNMP125-60 60 -- 1.370(34.80) 1.395(35.43) 1.800(45.72) 1.825(46.36) 7.0 (177.8) 28
1-1/2 LNMP150-15 15 LNMP150-45 45 -- 1.585(40.26) 1.620(41.15) 2.045(51.94) 2.080(52.83) 8.0 (203.2) 36
2LNMP200-15 15 LNMP200-30 30 -- 2.075(52.71) 2.100(53.34) 2.555(64.90) 2.590(65.79) 9.0 (228.6) 54
Type LNM-P
This nonmetallic liquidtight conduit is
ideally suited for continuous flexing
situations. It is often specified in “Power
Track” or cable carrier installations and on
industrial robots. It does not contain a
metal core which could fatigue from
repeated flexing or vibration.
Construction
LNM-P is of the Layered, Type-A
construction which incorporates a
smooth seamless inner core of flexible
PVC that is bonded to a covering of
flexible PVC. Between these layers is a
woven nylon mesh for added
reinforcement. The PVC material is a
high quality flame-retardant compound
which resists oils, mild acids and
exposure to sunlight.
Applications
General Use:
In accordance with CEC Rule 12-1002 (1)
the flexible metal conduit is permitted in or
on buildings of either combustible or non-
combustible constructions.
Restriction and Exception:
CEC Rule 12-1004 (a):“12 (3/8) trade
size flexible metal conduit shall be permitted
to be used for runs of not more than
1.5 m (5 ft) for the connection of equipment.”
and CEC Rule 12-1004 (b):“12 (3/8) trade
size liquidtight flexible conduit may be used
as permitted by this code.”
Securements with straps:
CEC Rule 12-1010 (3): “When flexible
metal conduit is installed, it shall be secured
at intervals not exceeding 1.5 m (5 ft) and
within 300 mm (12 in.) on each side of every
outlet box or fitting except where flexible
metal conduit is fished and except for
lengths of not over 900 mm (3 ft) at terminals
where flexibility is necessary.”
Conductor fill:
CEC Rule 12-1014 defines the maximum
number of conductor, the CEC Tables 6
provides the maximum number of
conductors of one size in trade sizes of
conduit,
CEC Table 8 provides the maximum
allowable per cent conduit fill, and CEC Table
9 provides the cross-sectional areas of
conduit.
Specific Use and applications:
Elevators, Hoistways, in accordance with
CEC Rules 38-021 (1) (a) (1) and 38-0221 (1)
(a) (iv)
Elevators, Cars, in accordance with CEC
Rules 38-021 (1) (b) (v)
Elevators, Within Machine Rooms, Control
Rooms and Machinery Spaces and Control
Spaces, in accordance with CEC Rule
38-021 (1) (c) (1)
Elevators, Conterweights, in accordance
with CEC Rule 38-021 (1) (d)
EScalators, in accordance with CEC Rule
38-021 (2)
Lifts for persons with physical disabilities, in
accordance with CEC Rule 38-021 (3)
Theater installation, in accordance with CEC
Rule 44-102 (1)
Working temperatures
-20°C to 60°C
Listing / Certification
Listed. Conforms to UL Standard
ANSI/UL 1660 type A
Certified. Conforms to CSA 22.2
No. 227.2 type A
Standard Colour
Safety Orange. Also available in
Black and Grey. Part numbers listed
designate Orange jacket.
Fittings
Fittings for Layered Conduit are for that
conduit only and are so identified by the
marking “FNMC-A”.
Recommendation:
“Suitable for use with 3700 Series, Type
A, Metal Fittings from Thomas & Betts”.
Refer to pgs. 101, 102.
LNM-P TYPE A
146
T&B Conduit Fittings
Liquatite®Flexible Conduit Nonmetallic
CONFITMRO_EN_ALL.pdf 146 11/28/2011 11:05:46 AM
147
T&B Conduit Fittings
Liquatite®Flexible Conduit Nonmetallic
Type NMC
Trade Inside Bend Weight Coil footage I.D. (in.) O.D. (in.)
Type Size Radius (lb/100ft) Length Min. Max. Min. Max.
NMC038TB 3/8” 2.00” 10 100 .484 .504 .690 .710
NMC050TB 1/2” 3.25” 11 100 .622 .642 .820 .840
NMC075TB 3/4” 4.25” 15 100 .820 .840 1.030 1.050
NMC100TB 1” 6.50” 25 100 1.041 1.066 1.290 1.315
NMC125TB 1-1/4“ 8.00” 34 100 1.380 1.410 1.630 1.660
NMC150TB 1-1/2” 9.00” 42 50 1.575 1.600 1.865 1.900
NMC200TB 2” 11.00” 60 50 2.020 2.045 2.340 2.375
NMC050-1000TB 1/2” 3.25” 11 1000 .622 .642 .820 .840
NMC075-500TB 3/4” 4.25” 15 500 .820 .840 1.030 1.050
See technical data next page.
Use with Bullet®Liquidtight Fittings.
*Available in other colours. Consult Customer Service for details.
Type NMT
Trade Inside Bend Weight Coil footage I.D. (in.) O.D. (in.)
Type Size Radius (lb/100ft) Length Min. Max. Min. Max.
NMT038TB 3/8” .7” 6 100 .484 .504 .690 .710
NMT050TB 1/2” .9” 8 100 .622 .642 .820 .840
NMT075TB 3/4” 1.1” 10 100 .820 .840 1.030 1.050
NMT100TB 1” 1.3” 15 100 1.041 1.066 1.290 1.315
NMT125TB 1-1/4 “ 1.7” 20 100 1.380 1.410 1.630 1.660
NMT150TB 1-1/2” 1.9” 26 50 1.575 1.600 1.865 1.900
NMT200TB 2” 2.4” 36 50 2.020 2.045 2.340 2.375
*Available in other colours. Consult Customer Service for details.
Recommended industrial applications:
• Machine tools.
• Motor hookups.
• Food processing equipment.
• Extensions from wireways.
• Sensor and microswitch wiring found in
control consoles.
Recommended industrial applications:
• Protection of fiber optic cable.
• Installation of instrumentation and control
cable.
• Indoor/outdoor lighting.
• Packaging equipment.
• Marine and shipboard wiring.
• Flexing—component wiring protection on
robots, graphic arts equipment, etc.
Type NMC
A general purpose nonmetallic liquidtight
conduit offers excellent protection to
wiring from abrasion, sunlight, mild acids,
alkaline and oils. Often used for air
conditioning hook-ups and other outdoor
applications.
Construction Type B
NMC is of the helically wound integral Type
B construction. It contains a spiral of rigid
PVC reinforcement imbedded within the
flexible PVC wall.
Type NM Specifications
Type NMC is intended for installation in
accordance with CEC Rule 12-1300 to
12-1306 for Liquidtight Flexible Conduit.
-For containment of 600 volt and lower
potential circuits.
Working Temperature
-20°C to 80°C/Dry 60°C/Wet
70°C/Oil
Listed. Conforms to Underwriters
Laboratories Standard ANSI/UL 1660
type B
Certified. Conforms to CSA 22.2
No. 227.2 type B.
The 3/8 through 1-1/4 in. trade
sizes are listed and marked for direct
burial and in poured concrete.
Standard Colour
Black
Type NMT
Type NMT is an Extra Flexible Liquidtight
Nonmetallic Tubing. This lightweight tubing
cuts easily and installs quickly. It is ideal for
wiring protection in tight quarters and for
tight bends. The thin flexible PVC skin
allows greater movement for many OEM
applications. Used for wiring harnesses,
laboratory, equipment, fiber optics, etc.
Construction
Co-extruded from both flexible and rigid
PVC. The rigid spiral PVC reinforcement is
imbedded within the wall of the tubing.
Working Temperature
-20°C to 70°C
UL Recognized.
Standard Colour
Black.
CONFITMRO_EN_ALL.pdf 147 11/28/2011 11:05:47 AM
Features / Benefits Applications
148
T&B Conduit Fittings
Liquatite®Flexible Conduit Nylon
UL recognized
Halogen free
Flame resistant
High impact and crush strength
Resistant to many
chemicals
Sunlight resistant
Extreme temperature range
Type CL
Provides the best mechanical strength
and protection of the Corrlok conduits.
Material
Halogen Free Nylon 6
Working Temperatures
-40°C to 105°C
Fitting Pullout
150 lb (1/2” and larger). To be used with
Kopex®fittings of the Corrlok®System.
Listing / Certification
UL Recognized Component, 600 V,
105°C, Vertical Flame, Liquidtight,
UV and Impact Tested.
Standard Colour
Black. Other colours available upon
request.
Nominal Dimensions Min. Inside Standard
Inside Outside Bend Radius Static Wt. Length
Cat. No. (in.) MM MW in. (mm) in. (mm) in. (mm) kg/30m (m)
CL140-30 1/4 10 7 0.226 (6.5) 0.394 (10.0) 0.8 (20.3) 2.0 30
CL516-30 5/16 12 10 0.374 (9.5) 0.512 (13.0) 1.0 (25.4) 2.5 30
CL10-30 3/8 16 12 0.452 (11.5) 0.622 (15.8) 1.5 (38.1) 5.0 30
CL11-30 1/2 20 17 0.633 (16.1) 0.826 (21.0) 1.7 (43.2) 7.0 30
CL12-30 3/4 25 23 0.846 (22.5) 1.122 (28.5) 2.0 (50.8) 9.5 30
CL13-15 1 32 29 1.063 (27.0) 1.358 (34.5) 2.5 (63.5) 13.0 15
CL14-15 1-1/4 40 36 1.380 (35.0) 1.673 (42.5) 2.8 (71.1) 16.0 15
CL15-15 1-1/2 50 48 1.810 (46.0) 2.145 (54.5) 3.3 (83.8) 19.0 15
Type CL Standard Weight
The Corrlok®System
Type - CLL
This light weight version provides many
of the same qualities of Type CL but
with Type CLL improved flexibility.
Material
Halogen Free Nylon 6
Working temperatures
-40°C to 105°C intermitting to 150°C
Fitting Pullout
40 lb (1/2” and larger). To be used with
Kopex®fittings of the Corrlok®System.
Listing / Certification
UL Recognized Component, 600 V,
105°C, Vertical Flame, Liquidtight,
UV and Impact Tested.
Standard Colour
Black. Other colours available upon
request.
Nominal Dimensions Min. Inside Standard
Inside Outside Bend Radius Static Wt. Length
Cat. No. (in.) MM MW in. (mm) in. (mm) in. (mm) kg/30m (m)
CLL10-30 3/8 16 12 0.452 (11.5) 0.622 (15.8) 0.7 (17.8) 3.4 30
CLL11-30 1/2 20 17 0.633 (16.1) 0.826 (21.0) 0.8 (20.3) 4.4 30
CLL12-30 3/4 25 23 0.865 (22.0) 1.122 (28.5) 1.2 (30.4) 6.7 30
CLL13-15 1 32 29 1.087 (27.6) 1.358 (34.5) 1.4 (35.6) 9.1 15
CLL14-15 1-1/4 40 36 1.420 (36.0) 1.673 (42.5) 2.4 (61.0) 11.0 15
CLL15-15 1-1/2 50 48 1.850 (47.0) 2.145 (54.5) 2.8 (71.1) 16.0 15
CLL17-10 2-1/2 70 70 2.645 (67.0) 3.150 (80.0) 6.3 (160.0) 32.0 10
CLL350-10 3-1/2 95 95 3.600 (91.5) 4.170 (106.0) 8.3 (210.8) 52.0 10
Type CLL Light Weight
Conduit size
Conduit size
Passenger rail vehicle wiring
Industrial control equipment
Machine tools
Textile machinery
Molding/extrusion equipment
Fiber optics
Medical equipment
The Corrlok®System is comprised of five
types of nylon, flexible corrugated
conduits designed for a wide range of
applications and are intended for use
with the new Kopex®series of fittings
and adapters. They are produced by an
extrusion/corrugation process resulting in
a flexible, seamless corrugated tube. The
internal corrugations are well rounded to
facilitate easier wire pulling.
The Corrlok®System provides a very
light weight, liquidtight flexible raceway
alternative that’s easy to work with
and stands up to tough environments.
Because the specially formulated nylons
used are nontoxic and self-extinguishing,
Corrlok®is a proven choice in confined
areas where hazards from fire are a
concern.
148-152-e.pdf 1 1/6/2012 9:51:57 AM
149
T&B Conduit Fittings
Liquatite®Flexible Conduit Nylon
Type CLFR
A new addition to the Corrlok®System
family of conduits, Type CFLR conduit is
made from a specially modified Nylon
Material with excellent self-extinguishing
characteristics and minimal smoke and
toxic gas gene-ration. CLFR is an excellent
choice for confined inhabited areas such as
Public Transit/Rail Vehicles, Subway
Stations, Tunnels, Etc.
Material:
Halogen Free Nylon 6 UL94 VO
Fitting Pullout
150 lb (1/2” and larger). To be used with
Kopex®fittings of the Corrlok®System.
Listing/Certification
UL Recognized Component, 600 V,
105°C, Vertical Flame, Liquidtight, UV
and Impact Tested.
Standard Colour:
Black. Other colours
available upon request.
Nominal Dimensions Min. Inside Standard
Inside Outside Bend Radius Static Wt. Length
Cat. No. (in.) MM MW in. (mm) in. (mm) in. (mm) kg/30m (m)
CLFR516-30
5/16 12 10 0.370 (9.4) 0.512 (13.0) 1.0 (25.4) 2.5 30
CLFR10-30
3/8 16 12 0.460 (11.7) 0.622 (15.8) 1.5 (38.1) 5.0 30
CLFR11-30
1/2 20 17 0.653 (16.6) 0.826 (21.0) 1.7 (43.2) 7.0 30
CLFR12-30
3/4 25 23 0.854 (21.7) 1.122 (28.5) 2.0 (51.0) 9.5 30
CLFR13-15
1 32 29 1.090 (27.7) 1.358 (34.5) 2.5 (63.5) 13.0 15
CLFR14-15
1-1/4 40 36 1.381 (35.1) 1.673 (42.5) 2.8 (71.1) 16.0 15
CLFR15-15
1-1/2 50 48 1.835 (46.6) 2.145 (54.5) 3.3 (83.8) 19.0 15
Corrlok®System Type CLFR, Low Fire Hazard
Nominal Dimensions Min. Inside Standard
Inside Outside Bend Radius Static Wt. Length
Cat. No. (in.) MM MW in. (mm) in. (mm) in. (mm) kg/30m (m)
CLR10-30 3/8 16 12 0.452 (11.5) 0.622 (15.8) 0.7 (17.8) 3.4 30
CLR11-30 1/2 20 17 0.633 (16.1) 0.826 (21.0) 0.8 (20.3) 4.4 30
CLR12-30 3/4 25 23 0.865 (22.0) 1.122 (28.5) 1.2 (30.5) 6.7 30
CLR13-15 1 32 29 1.087 (27.6) 1.358 (34.5) 1.4 (35.6) 9.1 15
CLR14-15 1-1/4 40 36 1.420 (36.0) 1.673 (42.5) 2.4 (61.0) 11.0 15
CLR15-15 1-1/2 50 48 1.850 (47.0) 2.145 (54.5) 2.8 (71.1) 16.0 15
CLR17-10 2-1/2 70 70 2.645 (67.0) 3.150 (80.0) 6.3 (160.0) 32.0 10
CLR350-10 3-1/2 95 95 3.600 (91.5) 4.170 (106.0) 8.3 (210.8) 52.0 10
Type CCG
This commercial grade product is
exceptionnally light weight and provides a
cost effective alternative.
Material:
Halogen Free Nylon 16
Working temperatures:
-20°C to 90°C
Standard Colour:
Black. Other colours
available upon request.
To be used with
Kopex®fittings of the
Corrlok®System.
Nominal Dimensions Min. Inside Standard
Inside Outside Bend Radius Static Wt. Length
Cat. No. (in.) MM MW in. (mm) in. (mm) in. (mm) kg/30m (m)
CCG10-30 3/8 16 12 0.452 (11.5) 0.622 (15.8) 1.0 (25.4) 3.0 30
CCG11-30 1/2 20 17 0.633 (16.1) 0.826 (21.0) 1.5 (38.1) 4.0 30
CCG12-30 3/4 25 23 0.870 (22.0) 1.122 (28.5) 1.8 (45.7) 6.0 30
CCG13-15 1 32 29 1.100 (27.9) 1.358 (34.5) 2.0 (51.0) 8.2 15
CCG14-15* 1-1/4 40 36 1.420 (36.0) 1.673 (42.5) 2.4 (61.0) 10.5 15
CCG15-15 1-1/2 50 48 1.850 (47.0) 2.145 (54.5) 2.8 (71.1) 15.3 15
Type CLFR Combustion & Flammability Properties
Test Value
Vertical Burn (Material)
UL94 V-O Rating No Flaming Drips
Vertical Burn (Conduit)
UL360 Pass No Flaming Drips
Flame Spread Index
ASTM E162 1.0 No Flaming Drips
Smoke Generation (Flaming)
ASTM E662 Ds 35@1.5 Min.
(NFPA-258) Ds 85@4.0 Min.
Smoke Generation (Non-Flaming)
ASTM E662 Ds 5@1.5 Min.
(NFPA-258) Ds 24@4.0 Min.
Toxic Gas Generation
BOMBARDIER SMP 800-C Pass
Test data is based on controlled laboratory conditions and does not necessarily reflect
performance in actual fire conditions. Additional product information available upon request.
Corrlok®System Type CLR, Robotics
Typ e CLR
Very light weight and extremely flexible.
Ideally suited for robotic equipment. This
tubing is intended for applications requiring
continuous, repeated flexible motion.
Material: Halogen Free Nylon 12
Working temperatures
-50°C to 95°C intermitting to 150°C
FIitting Pullout: 65 lb.To be used with
Kopex®fittings of the Corrlok®System.
Listing/ Certification
UL Recognized Component, 600 V,
105°C, Vertical Flame, Liquidtight, UV
and Impact Tested.
Standard Colour: Black. Other colours
available upon request.
Corrlok®System Type CCG, Commercial Grade
Conduit size
Conduit size
Conduit size
* Not available
148-152-e.pdf 2 1/6/2012 9:51:57 AM
150
T&B Conduit Fittings
Liquatite®Flexible Conduit Nylon
The Corrlok ®System now features KOPEX ®Fittings
The new, improved slim fitting is great
for use in tight areas and is molded in
high impact Nylon. The two piece
design is easier than ever to assemble
and to re-use. After sliding the backshell
onto the conduit, simply seat the
conduit into the fitting body and click
together. No tools required!
Fast Installation
Recognized
• Liquidtight — Equivalent to IP 65 and
NEMA 4
• 360° Retention — High pullout
strength
• Fitting Pullout — Minimum 150 lb
Straight
90° Angle
NPT Threaded Fittings
PG Thread Metric Thread
Thread Thread Thread
Cat. No. (in.) MM MW Size Cat. No. Size Cat. No. Size
CF-140 1/4 10 7 PG-7 - - - -
CF-516 5/16 12 10 PG-9 - - CFM-516 12 mm
CF-10 3/8 16 12 1/2 NPT CFP-10 PG-11 CFM-10 16 mm
CF-11 1/2 20 17 1/2 NPT CFP-11 PG-13.5 CFM-11 20 mm
CF-12 3/4 25 23 3/4 NPT CFP-12 PG-21 CFM-12 25 mm
CF-13 132291NPTCFP-13 PG-29 CFM-13 32 mm
CF-14 1-1/4 40 36 1-1/4 NPT CFP-14 PG-36 CFM-14 40 mm
CF-15 1-1/2 50 48 1-1/2 NPT CFP-15 PG-48 CFM-15 50 mm
Approx. Dimensions
Cat. No. A B C
CF-140 31/32 1-13/32 15/32
CF-516 1-3/32 1-3/8 15/32
CF-10 1-1/16 1-1/2 1/2
CF-11 1-5/16 1-1/2 1/2
CF-12 1-5/8 1-17/32 9/16
CF-13 2 1-21/32 21/32
CF-14 2-5/16 1-13/16 23/32
CF-15 2-13/16 1-13/16 23/32
NPT Threaded Fittings
PG Thread Metric Thread
Thread Unit Standard Thread Thread
Cat. No. (in.) MM MW Size Pack Carton Cat. No. Size Cat. No. Size
CF-140A 1/4 10 7 PG-7 1 - - - - -
CF-516A 5/16 12 10 PG-9 1 - - - CFM-516A 12 mm
CF-20 3/8 16 12 1/2 NPT 25 100 CFP-20 PG-11 CFM-20 16 mm
CF-21 1/2 20 17 1/2 NPT 25 50 CFP-21 PG-13.5 CFM-21 20 mm
CF-22TB 3/4 25 23 3/4 NPT 10 30 CFP-22 PG-21 CFM-22 25 mm
CF-23 132291NPT 1020 CFP-23 PG-29 CFM-23 32 mm
CF-24 1-1/4 40 36 1-1/4 NPT 5 10 CFP-24 PG-36 CFM-24 40 mm
CF-25 1-1/2 50 48 1-1/2 NPT 2 10 CFP-25 PG-48 CFM-25 50 mm
Approx. Dimensions
Cat. No. A B C
CF-140A 1-3/8 19/32 15/32
CF-516A 1-15/32 1-11/16 15/32
CF-20 1-5/8 1-27/32 1/2
CF-21 1-3/4 2 1/2
CF-22 2-3/16 2-5/16 9/16
CF-23 2-1/2 2-9/16 21/32
CF-24 2-3/4 3 23/32
CF-25 3-3/8 3-1/2 23/32
Fitting size
Fitting size
148-152-e.pdf 3 1/6/2012 9:51:58 AM
151
T&B Conduit Fittings
Liquatite®Flexible Conduit Nylon
Corrlok®System Flange, Jumbo Straight
Corrlok®System Type CTC, T Fitting
Corrlok®System Type TR, T Reducer
Screw
Unit Nominal Dimensions Required
Cat. No. (in.) MM MW Pack A B C D E F
CFF-17 2-1/2 70 70 1 2.362 3.149 3-7/8 2-1/16 4-3/16 17/64
CF-350 3-1/2 95 95 1 2.913 4.251 4-31/32 2-1/16 5-7/32 17/64
Nominal Dimensions Weight
Cat. No. (in.) MM MW A B C D Oz.
CTC-140 1/4 X 3 10 7 2-11/16 1-31/32 1-17/32 1-1/16 0.8
CTC-516 5/16 X 3 12 10 2-11/16 1-31/32 1-17/32 1-1/16 0.8
CTC-10 3/8 X 3 16 12 2-3/4 2 1-1/2 1-7/32 0.9
CTC-11 1/2 X 3 20 17 3-5/32 2-9/32 1-11/16 1-3/8 1.3
CTC-12 3/4 X 3 25 23 3-3/4 2-13/16 2-1/32 1-11/16 2.3
CTC-13 1 X 3 32 29 4-5/16 3-5/16 2-13/32 2 2.3
Trade Size reduce U.S. MM reduce MM
Cat. no. (in.) to Trade (NW) to (NW)
TR-516-140 5/16 ·1/4 12 (10) ·10 (7)
TR-10-516 3/8 ·5/16 16 (12) ·12 (10)
TR-11-516 1/2 ·5/16 20 (17) ·12 (10)
TR-11-10 1/2 ·3/8 20 (17) ·16 (12)
TR-12-516 3/4 ·5/16 25 (23) ·12 (10)
TR-12-10 3/4 ·3/8 25 (23) ·16 (12)
TR-12-11 3/4 ·1/2 25 (23) ·20 (17)
TR-13-11 1·1/2 32 (29) ·20 (17)
Corrlok®System Flange, Jumbo 90° Angle
Screw
Unit Nominal Dimensions Required
Cat. No. (in.) MM MW Pack A B C D E F
CFF-27 2-1/2 70 70 1 2.362 3.149 3-25/32 5-1/32 4-11/32 17/64
CFF-350A 3-1/2 95 95 1 2.913 4.251 4-31/32 6-17/32 5-11/16 17/64
Both the Flanged Straight and Flanged
90° Angle fittings on this page do not have
threaded ends but are intended
to be mounted as a bulkhead device. Part
numbers include clamps. Seals are
provided for liquidtight connections.
Fitting size
Fitting size
Fitting size
148-152-e.pdf 4 1/6/2012 9:51:58 AM
152
T&B Conduit Fittings
Liquatite®Flexible Conduit Nylon
Type MB Mounting Bracket
Nominal Dimensions Weight
Cat. No. (in.) MM MW A B C D E F Oz.
MB-140 1/4 10 7 7/8 1/2 15/16 15/32 5/16 5/32 0.1
MB-516 5/16 12 10 7/8 1/2 15/16 15/32 5/16 5/32 0.1
MB-10TB 3/8 16 12 1-1/16 19/32 1-1/16 17/32 11/32 3/16 0.1
MB-11 1/2 20 17 1-11/32 3/4 1-3/8 11/16 13/32 1/4 0.2
MB-12 3/4 25 23 1-23/32 15/16 1-23/32 13/16 13/32 1/4 0.3
MB-13 1 32 29 2-3/32 1-1/16 2-1/32 15/16 13/32 1/4 0.4
MB-14 1-1/4 40 36 2-17/32 1-9/32 2-15/32 1-1/16 13/32 1/4 0.7
MB-15 1-1/2 50 48 3-3/16 1-1/2 3-1/32 1-9/32 13/32 1/4 1.2
Type FTA Female Threaded Adapter
Internal
Thread
Cat. No. in. MM MW UNEF
FTA-U12516 1/2-28
FTA-U15516 5/16 12 10 5/8-24
FTA-U18516 3/4-20
FTA-U1810 16 12 3/4-20
FTA-U2310 3/8 15/16-20
FTA-U2311 15/16-20
FTA-U2411 1/2 20 17 1-20
FTA-U2911 13/16-18
FTA-U3411 1-3/8-18
FTA-U2312 15/16-20
FTA-U2912 3/4 25 23
1-3/16-18
FTA-U3412 1-3/8-18
FTA-U3512
1-7/16-18
Type FTA adapters have internal, female
UNEF threads which are sized to match
those of commonly used circular pin
fittings. This component provides a
secure means to attach these quick
disconnect multi-pin fittings to the
Corrlok System.
This assembly eliminates the need for
back shells and heat shrinkable boots
while providing excellent protection to
circuit conductors.
Other thread sizes and types available.
Consult your Regional Sales Office for
further details.
Type PSA Pro Sensor Adapters
Internal
Thread
Cat. No. in. MM MW UNEF
PSA-M8140
M8 X 1
PSA-M12140
PSA-M18140 1/4
10 7 M12 X 1
PSA-M130140
M18 X 1
M30 X 1.5
PSA-M12516
M12 X 1
PSA-M18516 3/4 16 12
M18 X 1
Type PSA adapters have internal ISO
Metric threads which match those found
on most barrel type proximity sensors.
Like the FTA series, this adapter provides
a means to mate proximity sensors to the
Corrlok System protect the sensor’s
cable.
The adapter is molded in transparent
nylon which permits monitoring of the
LED indicator built into many sensor
designs.
The Corrlok components provide Designers and Electricians with
many options for configuring and installing this raceway
system. These accessories allow a simplified, quick method of
assembly and are perfectly suited for pre-wiring of harnesses.
Corrlok Conduit Size
Corrlok Conduit Size
Corrlok Conduit Size
The Corrlok®System — Accessories
148-152-e.pdf 5 1/6/2012 9:51:59 AM
153
T&B Conduit Fittings
Liquatite®Flexible Conduit Engineering Information
Conduit Cutting
Benfield Vise
The Benfield cutting vise is
recommended for accurate, straight
cuts in the field. This light weight cast
iron vise can either be bench mounted
or carried in the tool box. The clamping
mechanism securely holds the flexible
conduit while the slots guide a hack
saw to ensure a clean square cut.
Suitable for conduit trade sizes of 3/8”
to 1-1/2”. Works well on other tubings
and materials too.
Order #BLC-1
Weight 2.4 lb
Cutting Flexible Conduits
Proper cutting methods for flexible conduits
are important to ensure a sealed
connection when assembled with intended
fittings. Furthermore, in the case of flexible
conduits containing steel, a clean, square
cut is necessary for establishing a good
connection for continuity of the ground
path.
Hand Cutting in the Field
When using a hand held hack saw, care
should be taken to make a square clean
cut. This can be easily achieved through
the use of the cutting vise shown on this
page. For best results, a blade having
24 to 32 teeth per inch with no-set is
recommended.
Repetitive Production Cutting
It has been our experience that in order to
achieve the best results, a band saw
having a blade with 24 to 32 teeth per inch
at a speed of 300 to 350 feet per minute
should be used. A no-set blade will
produce the cleanest cut. Conduit should
be held and supported in a safe manner.
Abrasive cut-off wheels and chop saws
are not recommended.
Flexible Metal Conduit
Trade Internal Total Area Over
Size Diameter 100 % 2 Wires 31% 2 Wires 40% 1 Wire 53 %
(in.) (in.) (mm) (in.2) (mm2) (in.2) (mm2) (in.2) (mm2) (in.2) (mm2)
5/16 0.312 (7.92) 0.076 (1.9) 0.024 (0.6) 0.031 (0.8) 0.041 (1.0)
3/8 0.375 (9.53) 0.110 (2.8) 0.034 (0.9) 0.044 (1.1) 0.059 (1.5)
7/16 0.437 (11.10) 0.150 (3.8) 0.046 (1.2) 0.060 (1.5) 0.079 (2.0)
1/2 0.625 (15.88) 0.307 (7.8) 0.095 (2.4) 0.123 (3.1) 0.163 (4.1)
3/4 0.812 (20.62) 0.518 (13.2) 0.161 (4.1) 0.207 (5.3) 0.274 (7.0)
1 1.000 (25.40) 0.785 (19.9) 0.243 (6.2) 0.314 (8.0) 0.416 (10.6)
1-1/4 1.250 (31.75) 1.227 (31.2) 0.380 (9.7) 0.491 (12.5) 0.650 (16.5)
1-1/2 1.500 (38.10) 1.767 (44.9) 0.548 (13.9) 0.707 (18.0) 0.937 (23.8)
2 2.000 (50.80) 3.142 (79.8) 0.974 (24.7) 1.257 (31.9) 1.665 (42.3)
2-1/2 2.500 (63.50) 4.909 (124.7) 1.522 (38.7) 1.964 (49.9) 2.602 (66.1)
3 3.000 (76.20) 7.069 (179.5) 2.191 (55.7) 2.827 (71.8) 3.746 (95.2)
3-1/2 3.500 (88.9) 9.621 (244.4) 2.983 (75.8) 3.848 (97.8) 5.099 (129.5)
4 4.000 (101.60) 12.566 (319.2) 3.896 (98.9) 5.027 (127.7) 6.660 (169.2)
Liquidtight Flexible Metal Conduit
Trade Internal Total Area Over
Size Diameter 100 % 2 Wires 31% 2 Wires 40% 1 Wire 53 %
(in.) (in.) (mm) (in.2) (mm2) (in.2) (mm2) (in.2) (mm2) (in.2) (mm2)
3/8 0.484 (12.29) 0.184 (4.7) 0.057 (1.4) 0.074 (1.9) 0.098 (2.5)
1/2 0.622 (15.80) 0.304 (7.7) 0.094 (2.4) 0.122 (3.1) 0.161 (4.1)
3/4 0.820 (20.83) 0.528 (13.4) 0.164 (4.2) 0.211 (5.4) 0.280 (7.1)
1 1.041 (26.44) 0.851 (21.6) 0.264 (6.7) 0.340 (8.6) 0.451 (11.5)
1-1/4 1.380 (35.05) 1.496 (38.0) 0.464 (11.8) 0.598 (15.2) 0.793 (20.1)
1-1/2 1.575 (40.01) 1.948 (49.5) 0.604 (15.3) 0.779 (19.8) 1.033 (26.2)
2 2.020 (51.31) 3.205 (81.4) 0.993 (25.2) 1.282 (32.6) 1.699 (43.1)
2-1/2 2.480 (62.99) 4.831 (122.7) 1.497 (38.0) 1.932 (49.1) 2.560 (65.0)
3 3.070 (77.98) 7.402 (188.0) 2.295 (58.3) 2.961 (75.2) 3.923 (99.6)
3-1/2 3.500 (88.90) 9.621 (244.4) 2.983 (75.8) 3.848 (97.8) 5.099 (129.5)
4 4.000 (101.60) 12.566 (319.2) 3.896 (98.9) 5.027 (127.7) 6.660 (169.2)
Conduit Wire Fill Charts
Per Canadian Electrical Code
CONFITMRO_EN_ALL.pdf 153 11/28/2011 11:05:48 AM
154
T&B Conduit Fittings
Liquatite®Flexible Conduit Engineering Information
Common Conversion
Length
English Measure Metric Measure
1 Foot 0.305 Meters
1 Meter 3.281 Feet
1 Inch 25.4 Millimeters
1 Millimeter 0.039 Inches
1 Inch 2.54 Centimeters
1 Centimeter 0.394 Inches
Weight
English Measure Metric Measure
1 Pound 454 Grams
1 Pound 0.454 Kilograms
1 Kilogram 2.205 Pounds
1 Gram 0.035 Ounces
1 Ounce 28.349 Grams
Temperature
C° = Degrees Centigrade
= Degrees Farenheit
C° = (F° - 32) 5 F° = (C° x 9) + 32
9 5
Knockout Hole Sizes
NPT Threaded Fittings
Fitting Knockout Thread Diameter
(in.) (in.) in. (mm)
3/8
1/2 NPT (12.7) 7/8 (22.2)
1/2 1/2 NPT (12.7) 7/8 (22.2)
3/4 3/4 NPT (19.1) 13/32 (27.8)
1 1 NPT (25.4) 123/64 (34.5)
1-1/4 1-1/4 NPT (31.8) 1-23/32(34.5)
1-1/2 1-1/2 NPT (38.1) 2 (50.8)
2 2 NPT (50.1) 2-1/2 (63.5)
Conduit Wire Fill Charts (continued)
Per Canadian Electrical Code
Liquidtight Non-Metallic Conduit Type A
Total Trade Internal Total Area Over
Size Diameter 100 % 2 Wires 31% 2 Wires 40% 1 Wire 53 %
(in.) (in.) (mm) (in.2) (mm2)(in.
2) (mm2)(in.
2) (mm2) (in.2) (mm2)
3/8 0.485 (12.32) 0.185 (4.7) 0.057 (1.5) 0.074 (1.9) 0.098 (2.5)
1/2 0.620 (15.75) 0.302 (7.7) 0.094 (2.4) 0.121 (3.1) 0.160 (4.1)
3/4 0.855 (20.70) 0.522 (13.3) 0.162 (4.1) 0.209 (5.3) 0.276 (7.0)
1 1.030 (26.16) 0.833 (21.2) 0.258 (6.6) 0.333 (8.5) 0.442 (11.2)
1-1/4 1.370 (34.80) 1.474 (37.4) 0.457 (11.6) 0.590 (15.0) 0.781 (19.8)
1-1/2 1.585 (40.26) 1.973 (50.1) 0.612 (15.5) 0.789 (20.0) 1.046 (26.6)
2 2.045 (51.94) 3.285 (83.4) 1.018 (25.9) 1.314 (33.4) 1.741 (44.2)
Liquidtight Non-Metallic Conduit Type B
Total Trade Internal Total Area Over
Size Diameter 100 % 2 Wires 31% 2 Wires 40% 1 Wire 53 %
(in.) (in.) (mm) (in.2) (mm2)(in.
2) (mm2)(in.
2) (mm2)(in.
2) (mm2)
3/8 0.485 (12.32) 0.185 (4.7) 0.057 (1.5) 0.074 (1.9) 0.098 (2.5)
1/2 0.620 (15.75) 0.302 (7.7) 0.094 (2.4) 0.121 (3.1) 0.160 (4.1)
3/4 0.855 (20.70) 0.522 (13.3) 0.162 (4.1) 0.209 (5.3) 0.276 (7.0)
1 1.030 (26.16) 0.833 (21.2) 0.258 (6.6) 0.333 (8.5) 0.442 (11.2)
1-1/4 1.370 (34.80) 1.474 (37.4) 0.457 (11.6) 0.590 (15.0) 0.781 (19.8)
1-1/2 1.585 (40.26) 1.973 (50.1) 0.612 (15.5) 0.789 (20.0) 1.046 (26.6)
2 2.045 (51.94) 3.285 (83.4) 1.018 (25.9) 1.314 (33.4) 1.741 (44.2)
CONFITMRO_EN_ALL.pdf 154 11/28/2011 11:05:48 AM
155
T&B Conduit Fittings
Liquatite®Flexible Conduit
All standard lengths packaged in
specially-designed, functional cartons
to eliminate knots and tangles. These
compact cartons save storage and
warehouse space, making handling
easier. Each carton label is clearly
marked and colour coded with conduit
size, type, colour, and footage as well as
the NEMA and NAED bar code standards.
Special Cut Lengths Available
Thomas & Betts can supply “cut-to-
length” orders. Consult your Regional
Sales Office for details.
LT - LOR - EF - LA - CSA - ALT - AT
ATLA - ATX - CEA - ZHLA - LAS
EMS - EMSP - NMC - NMT - ACEA
Standard Dimensions and Packaging Types Reel Sizes
Trade Size Inner dia. Outer Dia.
(in.) Type Min. Max. Min. Max.
1/4 - 0.245 0.265 0.450 0.470
5/16 - 0.385 0.405 0.570 0.590
3/8 10 0.484 0.504 0.690 0.710
1/2 11 0.622 0.642 0.820 0.840
3/4 12 1.820 0.840 1.030 1.050
1 13 1.041 1.066 1.290 1.315
1-1/4 14 1.380 1.410 1.630 1.660
1-1/2 15 1.575 1.600 1.865 1.900
2 16 2.020 2.045 2.340 2.375
2-1/2 17 2.480 2.505 2.840 2.875
3 18 3.070 3.100 3.460 3.500
1-1/2 350 3.500 3.540 3.960 4.000
4 19 4.000 4.040 4.460 4.500
5 500 4.975 5.035 5.505 5.565
6 600 6.015 6.075 6.565 6.625
Trade
Size 58” 42” 31” 31” Special 24”
(in.) LT-LA-EF LT-LA-EF LT LA EF LT LA EF LT-LA-EF
3/8 6,000 - 1,000 1,000 1,000 - - -
500
1/2 4,500 - 1,000 1,000 1,000 - -
-500
3/4 2,500 1,000 500 500 500 - -
--
1 1,500 - 400 400 400 - -
--
1-1/4 1,000 - 200 - 200 - 200
--
1-1/2 750 - - - - 150 150
150 -
2 500 - - - - 100 100
100 -
2-1/2 275 - - - - - -
--
3 175 - - - - - -
--
3-1/2 175 - - - - - -
--
4 100 - - - - - -
--
5 - --- -- -
--
6 - --- -- -
--
Approx. Reel Dimensions in. (mm)
“A” “BC”
24 (610) 19-1/2 (495) 12 (305)
31 (760) 19-1/2 (495) 12 (305)
31 (760) Special 19-1/2(495) 15 (381)
42 (1029) 20 (508) 24 (610)
58 (1421) 29-1/2 (749) 28 (711)
Trade Standard Standard
Size Carton Carton
Cat. No. (in.) All types Type LNM-P
038 3/8 30 75
050 1/2 30 60
075 3/4 30 50
100 13030
125 1-1/4 15 30
150 1-1/2 15 15
200 21515
250 2-1/2 8 -
300 38-
350 3-1/2 8 -
400 48-
500 58-
600 68-
Cartons
CONFITMRO_EN_ALL.pdf 155 11/28/2011 11:05:49 AM
156
T&B Conduit Fittings
Conduit Dimensional Data
Rigid Metal Conduit (Extract from CSA C22.2 No. 45.1)
Metric Threads Nominal Nominal External External Wall Wall
Trade Designator Imperial per Internal Dia. Internal Dia. Diameter Diameter Thickness Thickness
(As per CEC 2009) Trade Size in. (mm) (in.) (mm) (in.) (mm) (in.)
12 3/8 18 12.52 0.493 17.1 0.675 2.31 0.091
16 1/2 14 16.05 0.632 21.3 0.840 2.64 0.104
21 3/4 14 21.23 0.836 26.7 1.050 2.72 0.107
27 1 11-1/2 27.60 1.063 33.4 1.315 3.20 0.126
35 1-1/4 11-1/2 35.41 1.394 42.2 1.660 3.38 0.133
41 1-1/2 11-1/2 41.25 1.624 48.3 1.900 3.51 0.138
53 2 11-1/2 52.91 2.083 60.3 2.375 3.71 0.146
63 2-1/2 8 63.22 2.489 73.0 2.875 4.90 0.193
78 3 8 78.49 3.090 88.9 3.500 5.21 0.205
91 3-1/2 8 90.69 3.570 101.6 4.000 5.46 0.215
103 4 8 102.87 4.050 114.3 4.500 5.72 0.225
129 5 8 128.85 5.073 141.3 5.563 6.22 0.245
155 6 8 154.76 6.093 168.3 6.625 6.76 0.266
Knockout (sliphole) Sizes for Electrical Conduits and Fittings
Metric Knockout Diameter
Trade Designator
Diameter Imperial Minimum Nominal Maximum
(As per CEC 2009) Trade Size (mm) (in.) (mm) (in.) (mm) (in.)
16 1/2 21.84 0.860 22.33 0.875 23.01 0.906
21 3/4 27.79 1.094 28.17 1.109 28.96 1.140
27 1 34.52 1.359 34.93 1.375 35.71 1.406
35 1-1/4 43.66 1.719 44.04 1.734 44.83 1.765
Electrical Metallic Tubing (Extract from CSA C22.2 No. 83.1)
Metric Nominal Nominal Outside Outside Wall Wall
Trade Designator Imperial Internal Dia. Internal Dia. Diameter Diameter Thickness Thickness
(As per CEC 2009) Trade Size (mm) (in.) (mm) (in.) (mm) (in.)
16 1/2 15.80 0.622 217.9 0.705 1.07 0.042
21 3/4 20.93 0.824 23.4 0.921 1.24 0.049
27 1 26.64 1.049 29.5 1.161 1.45 0.057
35 1-1/4 35.05 1.380 38.4 1.512 1.65 0.065
41 1-1/2 40.89 1.610 44.2 1.740 1.65 0.065
53 2 52.50 2.067 55.8 2.197 1.65 0.065
63 2-1/2 69.37 2.731 73.0 2.874 1.83 0.072
78 3 85.24 3.355 88.9 3.500 1.83 0.072
91 3-1/2 97.38 3.834 101.6 4.000 2.11 0.083
103 4 110.08 4.334 114.3 4.500 2.11 0.083
CONFITMRO_EN_ALL.pdf 156 11/28/2011 11:05:49 AM
157
T&B Conduit Fittings
Conduit Dimensional Data
Flexible Metal Conduit (Extract from CSA C22.2 No. 56)
Minimum Minimum Maximum Maximum
Imperial Internal Diameter Internal Diameter External Diameter External Diameter
Trade Size (mm) (in.) (mm) (in.)
5/16 7.92 0.312 12.95 0.510
3/8 9.52 0.375 15.49 0.610
7/16 11.10 0.437 17.15 0.675
1/2 15.88 0.625 23.37 0.920
3/4 20.62 0.812 28.07 1.105
1 25.40 1.000 35.05 1.380
1-1/4 31.75 1.250 41.40 1.630
1-1/2 38.10 1.500 49.53 1.950
2 50.80 2.000 62.23 2.450
2-1/2 63.50 2.500 77.72 3.060
3 76.20 3.000 90.42 3.560
3-1/2 88.90 3.500 103.12 4.060
4 101.60 4.000 115.82 4.560
Liquidtight Flexible Conduit (Extract from CSA C22.2 No. 56)
Minimum Minimum Minimum Minimum Maximum Maximum
Imperial Internal Dia. Internal Dia. Overall Diameter Overall Diameter Overall Diameter Overall Diameter
Trade Size (mm) (in.) (mm) (in.) (mm) (in.)
3/8 12.29 0.484 17.5 0.690 18.0 0.710
1/2 15.80 0.622 20.8 0.820 21.3 0.840
3/4 20.83 0.820 25.2 1.030 26.7 1.050
1 26.44 1.041 32.8 1.290 33.4 1.315
1-1/4 35.05 1.380 41.4 1.630 42.2 1.660
1-1/2 40.01 1.575 47.4 1.865 48.3 1.900
2 51.31 2.020 59.4 2.340 60.3 2.375
2-1/2 62.99 2.480 72.1 2.840 73.0 2.875
3 77.98 3.070 87.9 3.460 88.9 3.500
3-1/2 88.90 3.500 100.6 3.960 101.6 4.000
4 101.60 4.000 113.3 4.460 114.3 4.500
Flexible Liquidtight Nonmetallic Conduit (Extract from CSA C22.2 No. 227.2)
Minimum Minimum Maximum Maximum
Imperial Internal Dia. Internal Dia. Internal Dia. Internal Dia. Minimum Dia. Minimum Dia. Maximum Dia. Maximum Dia.
Trade Size (mm) (in.) (mm) (in.) (mm) (in.) (mm) (in.)
3/8 12.32 0.485 13.83 0.505 19.18 0.755 19.69 0.775
1/2 15.75 0.620 16.26 0.640 23.11 0.910 23.62 0.930
3/4 20.70 0.815 21.21 0.835 29.21 1.150 29.72 1.170
1 26.16 1.030 27.05 1.065 35.94 1.415 36.58 1.440
1-1/4 34.80 1.370 35.43 1.395 45.72 1.800 46.36 1.825
1-1/2 40.26 1.585 41.15 1.620 51.94 2.045 52.83 2.080
2 51.94 2.045 52.83 2.080 66.17 2.605 67.06 2.640
CONFITMRO_EN_ALL.pdf 157 11/28/2011 11:05:49 AM
158
T&B Conduit Fittings
ConduitChemical Resistance Guide
NYLONS NYLONS
CHEMICAL % PVC PU 6 12 CHEMICAL % PVC PU 6 12
A
ASTM Fuel A CA
ASTM Fuel B DB
ASTM Fuel C B
ASTM Oil No. 1 BB
ASTM Oil No. 2 B
ASTM Oil No. 3 CBAA
Acetaldehyde 40% D B A
Acetamide 50% A A
Acetate Solvents D
Acetic Acid (Glacial) CDDC
Acetic Acid 40% D D C
Acetic Acid 10% B C B
Acetic Anhydride DDB
Acetone DDAA
Acetyl Bromide C
Acetyl Chloride C
Acetylene BAA
Acrylonitrite A
Adipic Acid A
Alcohols AA
Alcohols (Aliphatic) C
Alkalies A
Allyl Alcohol BB
Aluminium Salts AA
Aluminum Chloride AB
Aluminum Sulfate (Alums) AB
Aluminum Sulfide B
Alums BA
Ammonia BAA
Ammonia 10% A A
Ammonia (Anhydrous Liquids) D
Ammonia (Aqueous) A
Ammoniated Latex A
Ammonium Acetate B
Ammonium Carbonate B
Ammonium Chloride 10% A A
Ammonium Chloride A
Ammonium Hydroxide AA
Ammonium Nitrate B
Ammonium Persulfate B
Ammonium Salts BA
Ammonium Sulfate B
Ammonium Sulfide B
Ammonium Thicyanide B
Amyl Acetate DDAB
Amyl Alcohol CAA
Amyl Chloride C
Aniline DBB
Aniline Hydrochloride D
Aniline Oils D
Animal Fats & Oils AB
Aniseed Oil AA
Anthracene D
Antifreeze Compounds AA
Antimony Salts B
Aqua Regia DD
Aromatic Fuels D
Aromatic Hydrocarbons D
Arsenic Salts A
Asphalt D
Attar of Roses AA
B
Banana Oil D
Barium Carbonate B
Barium Chloride A
Barium Hydroxide AB
Barium Salts AA
Barium Sulfide A
Battery Acid 30% C B
Benzaldehyde 0.3 % A A
Benzaldehyde DCB
Benzene DDAA
Benzine (Petroleum Ether) CB
Benzoic Acid CBB
Benzole AA
Benzyl CC
Bitumen AA
Borax AAA
Bordeaux Mixture A
Boric Acid ABBA
Brake Fluid AA
Brake Fluid A B
Brine A
Bromine BCC
Bunker Oil B
Butane BAA
Butanol AB
Butyl Acetate DDAA
Butyl Alcohol BB
Butylene Glycol BA
Butyric Acid BA
C
Calcium Carbonate B
Calcium Chloride 10% A A
Calcium Chloride 20% A B D C
Calcium Hydroxide AB
Calcium Hypochlorite A
Calcium Nitrate B
Calcium Sulfate B
Camphor AA
Carbolic Acid (Phenol) B
Carbon Dioxide AA
Carbon Disulfide DBAA
Carbon Tetrachloride DDAB
Carbonic Acid A
Casein A
Castor Oil AB
Catechol 6% C B
Caustic Soda 40% A A A
Cello - Solv D
Chlorinated Hydrocarbons D
Chlorinated Lime DD
Chlorine BDD
Chlorine (water solution) < 5% C C B
Chlorine Gas (dry & wet) < 5% D C B
Chloroacetic Acid CDD
Chlorobenzene DAC
Chlorobromomethane BB
Chloroform DCC
Chrome Baths DC
Chromic Acid 1% D C B
Chromic Acid 10% B D D C
A- Good to excellent
B- Fair to Good
C- Fair to Limited
D- Unsatisfactory
PVC- Polyvinyl chloride
PU- Polyurethane
CONFITMRO_EN_ALL.pdf 158 11/28/2011 11:05:49 AM
159
T&B Conduit Fittings
ConduitChemical Resistance Guide
NYLONS NYLONS
CHEMICAL % PVC PU 6 12 CHEMICAL % PVC PU 6 12
C (cont’d)
Chromic /Sulfuric Acid DD
Chromium Potassium Sulfate B
Chromium Salts AA
Citric Acid AB
Coal Tar D
Coconut Oil CAA
Copper Salts 10% A A
Corn Oil A
Cottonseed Oil CB
Creosote D
Cresol CDDD
Cresylic Acid D
Cupric Chloride B
Cupric Nitrate B
Cupric Sulfate B
Cyclohexane BAA
Cyclohexanol AA
Cyclohexanone DAA
D
DDT Weed Killer A
DOP D
DTE Oil B
Decalin AA
Degreasing Fluids D
Detergents (dishwashing) AA
Di Iso Cyanate C
Di Methyl Formamide D
Di Methyl Hydrazine D
Di-isodecyl Phthalate D
Dibutyl Ether B
Dibutyl Phthalate DDAA
Dichlorobenzene C
Diesel Fuel DBAA
Diesel Oils CAA
Diester Oil B
Diethyl Ether AAA
Diethylene Glycol B
Dimethyl Acetamide D
Dimethyl Formamide DAB
Dioctyl Phthalate DAA
Dioxane AA
Dodecyl Mercaptan B
Dow General Weed Killer (H20) B
Dow General Weed Killer (Phenol) D
Dowtherm D
E
Edible Fats and Oils AA
Esters D
Ether DBAA
Ethyl Acetate DAA
Ethyl Alcohol CBAA
Ethyl Bromide C
Ethyl Chloride C
Ethylene Chloride AB
Ethylene Dichloride D
Ethylene Glycol BB
F
Fatty Acids AAA
Ferric Chloride AB
Ferric Nitrate B
Ferric Sulfate A
Ferrous Chloride AB
Ferrous Sulfate AB
Flourochlorohydrocarbons AA
Formaldehyde 40% D B C B
Formalin BB
Formamide BB
Formic Acid 85% D C
Formic Acid 10% A D C C
Formic Acid 40% D C
Freon CAA
Freon 12 AA
Freons D
Fuel Oil BBAA
Furfurol CBB
G
Gallic Acid A
Gasoline - 100 Octane CB
Glycerine ABAA
Glycol AA
Glycolic Acid B
Grease AB
Green Sulfate Liquor A
H
Heptachlor in Petroleum Solvents A
Heptane CBAA
Hexane CBAA
Hydraulic Fluid AA
Hydraulic Fluids -Ester Base DAA
Hydraulic Fluids-Petroleum Base CAA
Hydrazine D
Hydrobromic Acid AB
Hydrocarbon Oil B
Hydrochloric Acid 40% C
Hydrochloric Acid 1% C B
Hydrochloric Acid 10% A B D C
Hydrocyanic Acid B
Hydrofluoric Acid B
Hydrofluoric Acid 70% C
Hydrofluoroboric Acid A
Hydrofluorosilicic Acid A
Hydrogen A
Hydrogen Chloride < 2% C B
Hydrogen Chloride > 2% D C
Hydrogen Fluoride 40% D D
Hydrogen Peroxide 2% C B
Hydrogen Peroxide 30% D D
Hydrogen Peroxide 10%ABCB
Hydrogen Sulfide < 5% C A A
Hydrolodic Acid B
I
Ink CAA
Iodine Solution B
Iron Salts -Acid Soln. 20% D C
Iron Salts -Neut. Soln. 20% A A
Isooctane CBAA
Isopropanal B
Isopropyl Acetate D
Isopropyl Alcohol BAB
A- Good to excellent
B- Fair to Good
C- Fair to Limited
D- Unsatisfactory
PVC- Polyvinyl chloride
PU- Polyurethane
CONFITMRO_EN_ALL.pdf 159 11/28/2011 11:05:49 AM
160
T&B Conduit Fittings
ConduitChemical Resistance Guide
NYLONS NYLONS
CHEMICAL % PVC PU 6 12 CHEMICAL % PVC PU 6 12
J
P-4 Oil C
Jet Fuels (JP-3,4, and 5) C
K
Kerosene CBAA
Ketones D
L
Lacquer Thinners D
Lactic Acid 50% C B
Lactic Acid 5% B B A
Lactic Acid 90% D B
Lanolin AA
Lead Acetate B
Lead Salts AA
Linseed Oil ABAA
Lox B
Lubricating Oils, Greases, Soaps ABAA
M
MIL-D-5606 Oil C
MIL-L-7808 Oil B
Magnesium Chloride A
Magnesium Hydroxide 10% A A A
Magnesium Salts 10% B A A
Magnesium Sulfate A
Malathion 50 in Aromatics D
Malic Acid AC
Mercury AAA
Mercury Salts AA
Methanol BAB
Methyl Acetate D
Methyl Alcohol C
Methyl Bromide D
Methylene Chloride DDBC
Methyl Ethyl Ketone DDAA
Mineral Oil AAAA
Monochlorobenzene D
Motor Fuels AA
Motor Oil 20W BAA
Muriatic Acid (See Hydrochloric Acid)
N
Naphtha CB
Naphthalene DAA
Natural Gas B
Nickel Salts CAA
Nitric Acid DDD
Nitric Acid 10% A
Nitric Acid 35% A
Nitric Acid 70% D
Nitrobenzene DBB
Nitrogen A
Nitromethane AA
O
Octane AA
Oil of Turpentine AA
Oleic Acid ABAA
Oleum DDD
Oxalic Acid 10% A A B A
Oxygen AAA
Oxygen - Liquid D
Ozone <1 PPM A A A
P
Paint DB
Paint Thinners D
Palmitic Acid A
Paper Chemicals A
Paraffin Oil AA
Pentachlorophenol in Oil B
Pentane C
Perchloric Acid D
Perchloroethylene DDAA
Petroleum BAA
Petroleum Ether CAA
Petroleum Spirits D
Phenol BDCC
Phenyl Ethyl Alcohol BC
Phosphoric Acid 10% B C B
Phosphoric Acid 50% C C
Phosphoric Acid 85% A
Photographic Developer A
Phthalates D
Pitch B
Plasticizers (Phthalates, Phosphates) AA
Polyester Resin with Styrene AA
Potash AA
Potassium Bromide 10% A A
Potassium Chlorate 7% C B
Potassium Chlorate 5% B A
Potassium Cyanide B
Potassium Hydroxide A
Potassium Hydroxide 50% A A
Potassium Iodide 10% A A
Potassium Nitrate 10% A A
Potassium Permanganate 1% D D
Potassium Salts B
Potassium Sulfate 10% A A
Propane ABAA
Propanol AB
Propyl Alcohol BC
Propylene Glycol B
Pydraul D
Pydraul Oil D
Pyridine AA
R
Resorcinol DD
Ritchfield A” Weed Killer C
S
SEA No. 10 Oil B
Salicylic Acid AA
Salt AA
Seawater ABAA
Silicic Acid B
Silicone Oil AAA
Silver Nitrate CB
Silver Salts AA
Skydrol Oil -Type B DDAA
Soap B
Soap Solution 10% A A
Sodium Acetate B
Sodium Bicarbonate BAA
Sodium Bisulfite 10% B A A
Sodium Borate B
Sodium Bromide 10% B A
A- Good to excellent
B- Fair to Good
C- Fair to Limited
D- Unsatisfactory
PVC- Polyvinyl chloride
PU- Polyurethane
CONFITMRO_EN_ALL.pdf 160 11/28/2011 11:05:49 AM
161
T&B Conduit Fittings
ConduitChemical Resistance Guide
NYLONS NYLONS
CHEMICAL % PVC PU 6 12 CHEMICAL % PVC PU 6 12
Sodium Carbonate B
Sodium Carbonate 10% A A
Sodium Chlorate B
Sodium Chloride BAA
Sodium Chlorite 5% C C
Sodium Cyanide AB
Sodium Dichromate B
Sodium Ferrocyanide B
Sodium Fluoride B
Sodium Hydrosulfiite B
Sodium Hydroxide B
Sodium Hydroxide 40% A A
Sodium Hydroxide 50% A
Sodium Hypochlorite 5% C B
Sodium Nitrate B
Sodium Nitrate 10% A A
Sodium Nitrite 5% C B
Sodium Perborate 5% B A
Sodium Phosphate 10% A A
Sodium Silicate B
Sodium Sulfate 10% A A
Sodium Sulfide 10% B A A
Sodium Sulfite 10% A A
Sodium Thiosulfite AA
Solvent Naphtha AA
Solvesso D
Stoddard Solvent D
Styrene DB
Sulfur AA
Sulfur Dioxide <5% B C B
Sulfur Dioxide (Liquid) D
Sulfuric Acid 2% D B
Sulfuric Acid 10% D B
Sulfuric Acid 20% D
Sulfuric Acid 25% D C
Sulfuric Acid 50% A
Sulfuric Acid 98% D
Sulfurous Acid B
T
Tall Oil D
Tallow AA
Tannic Acid AC
Tar AA
Tartaric Acid 10% B A A
Tea AA
Tetra Ethyl Lead D
Tetra Hydro Furan DAA
Tetraline AA
Thionyl Chloride DD
Tin Salts B
Titanium Salts B
Toluene DDAA
Toluol D
Transformer Oil CAA
Transmission Oil B
Trichloroethane D
Trichlorethylene DBB
Trichloroacetic Acid D
Trichloroethylene D
Tricresyl Phosphate D
Tricresyl Phosphate (Skydrol) D
Triethanol Amine CB
Trisodium Phosphate B
Tung Oil C
Turpentine CBAA
U
Urea 20% B A A
V
Varnish B
Varsol D
Vaseline AA
Vegetable Oils and Juices ABAA
Vinegar ABA
Vinyl Chloride D
W
Water AAA
Water 23°C B
Water 70°C B
Wax AA
Wood Preservatives D
X
Xylene DCAA
Xylols D
Z
Zinc Chloride 10% A B B A
Zinc Sulfate AB
CHEMICAL Resistance Chart- Type ATX
Thermoplastic Rubber jacket
% Tensile % % Volume
Test Method Strength Elongation Increase
ASTM #2 OIL
UL - 1581 7 days/60°C 90 98 N/A
4 days/100°C 66 70 N/A
18 hrs/120°C 45 40 N/A
Brake Fluid
ASTM D - 471 72 hrs/100°C 80 90 -7
Ethylene Glycol
ASTM D - 471 72 hrs./100°C 95 90 2
Methanol
ASTM D - 471 72 hrs./ 100°C 95 90 0
Silicone Oil
ASTM D - 471 72 hrs./100°C 100 80 -14
5 % Salt Water
ASTM D - 471 72 hrs./100°C 80 100 1
Vegetable Oil
ASTM D - 471 18 hrs./120°C 60 70 N/A
Animal Oil
ASTM D - 471 18 hrs./120°C 70 75 N/A
10W-40 Motor Oil
ASTM D - 471 72 hrs./100°C 50 55 25
Gasoline
ASTM D - 471 72 hrs./ 100°C 40 35 17
Transmission Oil
ASTM D - 471 72 hrs./100°C 50 50 32
Freon2
ASTM D - 471 72 hrs./50°C 93 84 N/A
This information is provided as a guide line only. No guarantee is
implied. Results are based on controlled laboratory tests and not on
installed end-product applications. Electri-Flex recommends that
samples be exposed to and observed in actual service
conditions for extreme or unusual situations.
A- Good to excellent
B- Fair to Good
C- Fair to Limited
D- Unsatisfactory
PVC- Polyvinyl chloride
PU- Polyurethane
CONFITMRO_EN_ALL.pdf 161 11/28/2011 11:05:49 AM
Alphanumeric Index
Catalogue Page Catalogue Page Catalogue Page
Number Number Number Number Number Number
162
ABR038-15 143
ABR038-30 143
ABR038-300 143
ABR038-8 143
ABR050-15 143
ABR050-30 143
ABR050-300 143
ABR050-8 143
ABR075-15 143
ABR075-150 143
ABR075-30 143
ABR075-8 143
ABR100-120 143
ABR100-15 143
ABR125-120 143
ABR125-15 143
ABR150-8 143
ABR150-90 143
ABR200-45 143
ABR200-8 143
ABR250-8 143
ABR300-8 143
ABR350-8 143
ABR400-8 143
ABRH038 143
ABRH050 143
ABRH075 143
ABRH100 143
ABRH125 143
ABRH150 143
ABRH200 143
ABRH250 143
ABRH300 143
ABRH400 143
ABRH716 143
ACEA038 138
ACEA038-60 138
ACEA050 138
ACEA050-30 138
ACEA050-300 138
ACEA075 138
ACEA075-150 138
ACEA075-30 138
ACEA075-45 138
ACEA100 138
ACEA100-120 138
ACEA100-30 138
ACEA125 138
ACEA125-15 138
ACEA125-75 138
ACEA150 138
ACEA150-15 138
ACEA150-45 138
ACEA200 138
ACEA200-15 138
ACEA200-30 138
ACEA250 138
ACEA250-8 138
ACEA300 138
ACEA300-8 138
ACEA400 138
ACEA400-8 138
ACEA500 138
ACEA600 138
ALT038-150 136
ALT038-30 136
ALT038-300 136
ALT050-150 136
ALT050-30 136
ALT050-300 136
ALT075-150 136
ALT075-30 136
ALT075-300 136
ALT100-120 136
ALT100-30 136
ALT125-15 136
ALT125-60 136
ALT150-15 136
ALT150-45 136
ALT200-15 136
ALT200-30 136
ALT250-8 136
ALT350-8 136
ALT400-8 136
ALT500-8 136
ALT600-8 136
AT038-150 135
AT038-30 135
AT038-300 135
AT050-150 135
AT050-30 135
AT050-300 135
AT075-150 135
AT075-30 135
AT075-300 135
AT100-120 135
AT100-30 135
AT125-15 135
AT125-60 135
AT150-15 135
AT150-45 135
AT200-15 135
AT200-30 135
AT250-8 135
AT300-8 135
AT350-8 135
AT400-8 135
AT500-8 135
AT600-8 135
ATLA038-150 134
ATLA038-30 134
ATLA038-300 134
ATLA050-150 134
ATLA050-30 134
ATLA050-300 134
ATLA075-150 134
ATLA075-30 134
ATLA075-300 134
ATLA100-120 134
ATLA100-30 134
ATLA125-15 134
ATLA125-60 134
ATLA150-15 134
ATLA150-45 134
ATLA200-15 134
ATLA200-30 134
ATLA250-8 134
ATLA300-8 134
ATLA350-8 134
ATLA400-8 134
ATX038-150 135
ATX038-30 135
ATX038-300 135
ATX050-150 135
ATX050-30 135
ATX050-300 135
ATX075-150 135
ATX075-30 135
ATX075-300 135
ATX100-120 135
ATX100-30 135
ATX125-15 135
ATX125-60 135
ATX150-15 135
ATX150-45 135
ATX200-15 135
ATX200-30 135
ATX250-8 135
ATX300-8 135
ATX400-8 135
BG050-14-20 14
BG050-14-4 14
BG075-14-20 14
BG075-14-4 14
BG100-14-20 14
BG100-14-4 14
BG125-14-20 14
BG150-14-20 14
BG200-14-20 14
CONFITMRO_EN_ALL.pdf 162 11/28/2011 11:05:50 AM
Catalogue Page Catalogue Page Catalogue Page
Number Number Number Number Number Number
Alphanumeric Index
163
BG250-14-20 14
BG250-6-40 14
BG300-14-20 14
BG300-6-40 14
BG350-14-20 14
BG350-6-40 14
BG400-14-20 14
BG400-6-40 14
BG500-14-20 14
BG500-6-40 14
BG600-14-20 14
BG600-6-40 14
BGA050-14-20 14
BGA050-14-4 14
BGA075-14-20 14
BGA075-14-4 14
BGA100-14-20 14
BGA100-14-4 14
BGA125-14-20 14
BGA150-14-20 14
BGA200-14-20 14
BGA250-14-20 14
BGA250-6-40 14
BGA300-14-20 14
BGA300-6-40 14
BGA350-14-20 14
BGA350-6-40 14
BGA400-14-20 14
BGA400-6-40 14
BGA500-14-20 14
BGA500-6-40 14
BGA600-14-20 14
BGAT600-6-40 14
BR038 142
BR038-15 142
BR038-30 142
BR038-300 142
BR038-75 142
BR038-8 142
BR050 142
BR050-15 142
BR050-30 142
BR050-300 142
BR050-8 142
BR075 142
BR075-15 142
BR075-150 142
BR075-30 142
BR075-8 142
BR100 142
BR100-120 142
BR100-15 142
BR125 142
BR125-120 142
BR125-15 142
BR150 142
BR150-8 142
BR150-90 142
BR200 142
BR200-45 142
BR200-8 142
BR250 142
BR250-8 142
BR300 142
BR300-8 142
BR350 142
BR350-8 142
BR400 142
BR400-8 142
CBLA038-150 132
CBLA038-30 132
CBLA038-300 132
CBLA050-150 132
CBLA050-30 132
CBLA050-300 132
CBLA075-150 132
CBLA075-30 132
CBLA075-300 132
CBLA100-120 132
CBLA100-30 132
CBLA125-15 132
CBLA125-60 132
CBLA150-15 132
CBLA150-45 132
CBLA200-15 132
CBLA200-30 132
CBLA250-8 132
CBLA250-80 132
CBLA300-50 132
CBLA300-8 132
CBLA350-50 132
CBLA350-8 132
CBLA400-30 132
CBLA400-8 132
CC-ISO-16-G 81
CC-ISO-20-G 81
CC-ISO-25-G 81
CC-ISO-32-G 81
CC-NPT1-B 81
CC-NPT1-G 81
CC-NPT12-B 81
CC-NPT12-G 81
CC-NPT34-B 81
CC-NPT34-G 81
CC-NPT38-B 81
CC-NPT38-G 81
CC-PG11-G 81
CC-PG135-G 81
CC-PG16-G 81
CC-PG21-G 81
CC-PG29-G 81
CC-PG36-G 81
CC-PG7-G 81
CC-PG9-G 81
CCG10-30 149
CCG11-30 149
CCG12-30 149
CCG13-15 149
CCG14-15 149
CCG15-15 149
CC11-38 82
CC11-38P 82
CC135-50 82
CC16-50 82
CC21-75 82
CC29-100 82
CC36-125 82
CC42-150 82
CEA038-30 137
CEA038-300 137
CEA050-30 137
CEA050-300 137
CEA075-150 137
CEA075-30 137
CEA100-120 137
CEA100-30 137
CEA125-15 137
CEA125-60 137
CEA150-15 137
CEA150-45 137
CEA200-15 137
CEA200-30 137
CEA250-8 137
CEA300-8 137
CEA400-8 137
CEA500-8 137
CEA600-8 137
CF-10 150
CF-11 150
CF-12 150
CF-13 150
CF-14 150
CF-140 150
CF-140A 150
CF-15 150
CF-20 150
CF-21 150
CF-22 150
CF-22TB 150
163-E.pdf 1 6/18/2012 2:02:21 PM
Alphanumeric Index
Catalogue Page Catalogue Page Catalogue Page
Number Number Number Number Number Number
164
CF-23 150
CF-24 150
CF-25 150
CF-350 151
CF-516 150
CF-516A 150
CFF-17 151
CFF-27 151
CFF-350A 151
CFM-10 150
CFM-11 150
CFM-12 150
CFM-13 150
CFM-14 150
CFM-15 150
CFM-20 150
CFM-21 150
CFM-22 150
CFM-23 150
CFM-24 150
CFM-25 150
CFM-516 150
CFM-516A 150
CFP-10 150
CFP-11 150
CFP-12 150
CFP-13 150
CFP-14 150
CFP-15 150
CFP-20 150
CFP-21 150
CFP-22 150
CFP-23 150
CFP-24 150
CFP-25 150
CI-1703PL 81
CG11-38 82
CG11-38P 82
CG135-50 82
CG16-50 82
CG21-75 82
CG29-100 82
CG36-125 82
CG42-150 82
CL10-30 148
CL11-30 148
CL12-30 148
CL13-15 148
CL14-15 148
CL140-30 148
CL15-15 148
CL516-30 148
CLFR10-30 149
CLFR11-30 149
CLFR12-30 149
CLFR13-15 149
CLFR14-15 149
CLFR15-15 149
CLFR516-30 149
CLL10-30 148
CLL11-30 148
CLL12-30 148
CLL13-15 148
CLL14-15 148
CLL15-15 148
CLL17-10 148
CLL350-10 148
CLR10-30 149
CLR11-30 149
CLR12-30 149
CLR13-15 149
CLR14-15 149
CLR15-15 149
CLR17-10 149
CLR350-10 149
CSA038-150 133
CSA038-30 133
CSA038-300 133
CSA050-150 133
CSA050-30 133
CSA050-300 133
CSA075-150 133
CSA075-30 133
CSA075-300 133
CSA100-120 133
CSA100-30 133
CSA125-15 133
CSA125-60 133
CSA150-15 133
CSA150-45 133
CSA200-15 133
CSA200-30 133
CSA250-8 133
CSA300-8 133
CSA400-8 133
CXP722 82
CXP723 82
CXP724 82
CXP725 82
CXP726 82
CXP727 82
CTC-10 151
CTC-11 151
CTC-12 151
CTC-13 151
CTC-140 151
CTC-516 151
EF038-150 130
EF038-30 130
EF038-300 130
EF050-150 130
EF050-30 130
EF050-300 130
EF075-150 130
EF075-30 130
EF075-300 130
EF100-120 130
EF100-30 130
EF125-15 130
EF125-75 130
EF150-15 130
EF150-45 130
EF200-15 130
EF200-30 130
EMS038-150 141
EMS038-30 141
EMS050-150 141
EMS050-30 141
EMS075-150 141
EMS075-30 141
EMS100-120 141
EMS100-30 141
EMS125-15 141
EMS125-60 141
EMS150-15 141
EMS150-45 141
EMS200-15 141
EMS200-30 141
EMS250-8 141
EMS300-8 141
EMS400-8 141
EMSP038-150 141
EMSP038-30 141
EMSP050-150 141
EMSP050-30 141
EMSP075-150 141
EMSP075-30 141
EMSP100-120 141
EMSP100-30 141
FTA-U12516 152
FTA-U15516 152
FTA-U1810 152
FTA-U18516 152
FTA-U2310 152
FTA-U2311 152
FTA-U2312 152
FTA-U2411 152
CONFITMRO_EN_ALL.pdf 164 11/28/2011 11:05:50 AM
Catalogue Page Catalogue Page Catalogue Page
Number Number Number Number Number Number
Alphanumeric Index
165
FTA-U2911 152
FTA-U2912 152
FTA-U3411 152
FTA-U3412 152
FTA-U3512 152
GR1W 97
GR2W 97
GR3W 97
GR4W 97
GR5W 97
H050-TB 28
H050BHD 30
H050CAP 31
H050GR-C 29
H050TBF 30
H050TBH 30
H075-TB 28
H075BHD 30
H075CAP 31
H075GR-C 29
H075TBF 30
H075TBH 30
H100-TB 28
H100BHD 30
H100CAP 31
H100GR-C 29
H100TBF 30
H100TBH 30
H125-TB 28
H125BHD 30
H125CAP 31
H125GR-C 29
H125TBF 30
H125TBH 30
H150-075ORGR-TB 31
H150-100ORGR-TB 31
H150-125ORGR-TB 31
H150-TB 28
H150BHD 30
H150CAP 31
H150GR-C 29
H150TBF 30
H150TBH 30
H200-TB 28
H200BHD 30
H200CAP 31
H200GR-C 29
H200TBF 30
H200TBH 30
H250-200ORGR-TB 31
H250-TB 28
H250BHD 30
H250CAP 31
H250GR-C 29
H300-TB 28
H300BHD 30
H300CAP 31
H300GR-C 29
H350-TB 28
H350BHD 30
H350CAP 31
H350GR-C 29
H400-TB 28
H400BHD 30
H400CAP 31
H400GR-C 29
H500-TB 28
H500BHD 30
H500CAP 31
H500GR-C 29
H600-TB 28
H600BHD 30
H600CAP 31
H600GR-C 29
HLT050DATA 78
HLT050 78
HLT075 78
HLT100 78
HLT125 78
HLT150 78
HLT200 78
L050GR-C 29
L075GR-C 29
L100GR-C 29
L125GR-C 29
L150GR-C 29
L200GR-C 29
L250GR-C 29
L300GR-C 29
L350GR-C 29
L400GR-C 29
L500GR-C 29
L600GR-C 29
LA038-150 131
LA038-30 131
LA038-300 131
LA050-150 131
LA050-30 131
LA050-300 131
LA075-150 131
LA075-30 131
LA075-300 131
LA100-120 131
LA100-30 131
LA125-15 131
LA125-60 131
LA150-15 131
LA150-45 131
LA200-15 131
LA200-30 131
LA250-8 131
LA250-80 131
LA300-50 131
LA300-8 131
LA350-50 131
LA350-8 131
LA400-30 131
LA400-8 131
LAS038-150 140
LAS038-30 140
LAS050-150 140
LAS050-30 140
LAS075-150 140
LAS075-30 140
LAS100-120 140
LAS100-30 140
LN501 81
LN502 81
LN503 81
LN-PG11-G 81
LN-PG16-G 81
LN-PG135-G 81
LN-PG21-G 81
LN-PG29-G 81
LN-PG36-G 81
LN-PG7-G 81
LN-PG9-G 81
LN-ISO16-G 81
LN-ISO20-G 81
LN-ISO25-G 81
LN-ISO32-G 81
LNMP038-150 146
LNMP038-300 146
LNMP038-75 146
LNMP050-150 146
LNMP050-300 146
LNMP050-60 146
LNMP075-150 146
LNMP075-50 146
LNMP100-120 146
LNMP100-30 146
LNMP125-30 146
LNMP125-60 146
LNMP150-15 146
LNMP150-45 146
LNMP200-15 146
LNMP200-30 146
LOR038-150 130
CONFITMRO_EN_ALL.pdf 165 11/28/2011 11:05:50 AM
Alphanumeric Index
Catalogue Page Catalogue Page Catalogue Page
Number Number Number Number Number Number
166
LOR038-30 130
LOR038-300 130
LOR050-150 130
LOR050-300 130
LOR050-50 130
LOR075-150 130
LOR075-30 130
LOR075-300 130
LOR100-120 130
LOR100-30 130
LOR125-15 130
LOR125-60 130
LOR150-15 130
LOR200-15 130
LOR250-8 130
LOR300-8 130
LOR350-8 130
LOR400-8 130
LOR500-8 130
LOR600-8 130
LT025-75 129
LT032-75 129
LT038-150 129
LT038-30 129
LT038-300 129
LT050-150 129
LT050-30 129
LT050-300 129
LT075-150 129
LT075-30 129
LT075-300 129
LT100-120 129
LT100-30 129
LT100M 109
LT100P 108
LT125-15 129
LT125-75 129
LT125M 109
LT125P 108
LT150-15 129
LT150-45 129
LT150M 109
LT150P 108
LT200-15 129
LT200-30 129
LT200M 109
LT200P 108
LT250-8 129
LT250-80 129
LT300-50 129
LT300-8 129
LT350-50 129
LT350-8 129
LT38M 109
LT38M-ISO20 110
LT38P 108
LT38P-ISO20 110
LT400-30 129
LT400-8 129
LT4100M 109
LT4100P 108
LT4125M 109
LT4125P 108
LT4150M 109
LT4150P 108
LT4200M 109
LT4200P 108
LT438M 109
LT438M-ISO20 110
LT438P 108
LT450M 109
LT450M-ISO20 110
LT450P 108
LT475M 109
LT475M-ISO25 110
LT475P 108
LT500-8 129
LT50M 109
LT50M-ISO20 110
LT50P 108
LT50P-ISO20 110
LT600-8 129
LT75M 109
LT75M-ISO25 110
LT75P 108
LT75P-ISO25 110
LT9100M 109
LT9100P 108
LT9125M 109
LT9125P 108
LT9150M 109
LT9150P 108
LT9200M 109
LT9200P 108
LT938M 109
LT938M-ISO20 110
LT938P 108
LT938P-ISO20 110
LT950M 109
LT950M-ISO20 110
LT950P 108
LT950P-ISO20 110
LT975M 109
LT975M-ISO25 110
LT975P 108
LTA03810 105
LTA03814 105
LTA05014 105
LTA05016 105
LTA05018 105
LTA07516 105
LTA07518 105
LTA07520 105
LTA10020 105
LTA10024 105
MB-10TB 152
MB-11 152
MB-12 152
MB-13 152
MB-14 152
MB-140 152
MB-15 152
MB-516 152
MSA05014 106
MSA05016 106
MSA05018 106
MSA07516 106
MSA07518 106
MSA07520 106
MSA10020 106
MSA10024 106
MSA10032 106
MSA10036 106
NMC038TB 147
NMC050-1000TB 147
NMC050TB 147
NMC075-500TB 147
NMC075TB 147
NMC100TB 147
NMC125TB 147
NMC150TB 147
NMC200TB 147
NMT038TB 147
NMT050TB 147
NMT075TB 147
NMT100TB 147
NMT125TB 147
NMT150TB 147
NMT200TB 147
PG11-38 82
PG16-50 82
PG21-75 82
PG29-100 82
PG29-125 82
PG36-125 82
PG36-150 82
PSA-M12140 152
PSA-M12516 152
PSA-M130140 152
CONFITMRO_EN_ALL.pdf 166 11/28/2011 11:05:50 AM
Catalogue Page Catalogue Page Catalogue Page
Number Number Number Number Number Number
Alphanumeric Index
167
PSA-M18140 152
PSA-M18516 152
PSA-M30516 152
PSA-M8140 152
SC4-KIT 78
SC65 78
SL038-75 144
SL050-45 144
SL050M-45 144
SL075-30 144
SL100-15 144
SL100M-15 144
SL140-75 144
SL316-75 144
SL340-45 144
SL380-75 144
SL516-75 144
SL716-75 144
SL916-45 144
TCF050-27AL 77
TCF050-40AL 77
TCF050-54AL 77
TCF050-67AL 77
TCF050-78AL 77
TCF075-40AL 77
TCF075-54AL 77
TCF075-67AL 77
TCF075-78AL 77
TCF075-88AL 77
TCF100-100AL 77
TCF100-109AL 77
TCF100-78AL 77
TCF100-88AL 77
TCF125-109AL 77
TCF125-128Al 77
TCF125-147AL 77
TCF150-115AL 77
TCF150-140AL 77
TCF150-165AL 77
TCF200-153AL 77
TCF200-186AL 77
TCF200-219AL 77
TCF250-252AL 77
TCF300-278AL 77
TCF300-304AL 77
TCF300-330AL 77
TR-10-516 151
TR-11-10 151
TR-11-516 151
TR-12-10 151
TR-12-11 151
TR-12-516 151
TR-13-11 151
TR-516-140 151
TRIB-100 18
TRIB-125 18
TRIB-150 18
TRIB-200 18
TRIB-250 18
TRIB-300 18
TRIB-350 18
TRIB-400 18
TRIB-50 18
TRIB-75 18
UG100-15 145
UG120-15 145
UG125-15 145
UG150-15 145
UG200-15 145
UG250-15 145
UG300-15 145
UG340-15 145
UG380-15 145
USL120 144
USL120-75 144
USL380 144
USL380-75 144
USL516 144
USL516-75 144
USL716 144
USL716-75 144
USL916 144
USL916-75 144
VJC038-30 145
VJC050-30 145
VJC050M-30 145
VJC075-30 145
VJC100-30 145
VJC100M-30 145
WMG-LT1 93
WMG-LT10 93
WMG-LT2 93
WMG-LT3 93
WMG-LT4 93
WMG-LT5 93
WMG-LT6 93
WMG-LT7 93
WMG-LT8 93
WMG-LT9 93
WMG-PC1 80
WMG-PC10 80
WMG-PC11 80
WMG-PC12 80
WMG-PC13 80
WMG-PC14 80
WMG-PC15 80
WMG-PC16 80
WMG-PC17 80
WMG-PC18 80
WMG-PC19 80
WMG-PC2 80
WMG-PC20 80
WMG-PC21 80
WMG-PC22 80
WMG-PC3 80
WMG-PC4 80
WMG-PC5 80
WMG-PC6 80
WMG-PC7 80
WMG-PC8 80
WMG-PC9 80
ZHLA038-150 139
ZHLA038-30 139
ZHLA038-300 139
ZHLA050-150 139
ZHLA050-30 139
ZHLA050-300 139
ZHLA075-150 139
ZHLA075-30 139
ZHLA075-300 139
ZHLA100-120 139
ZHLA100-30 139
ZHLA125-15 139
ZHLA125-60 139
ZHLA150-15 139
ZHLA150-45 139
ZHLA200-15 139
ZHLA200-30 139
ZHLA250-8 139
ZHLA300-8 139
ZHLA350-8 139
ZHLA400-8 139
100BP 126
100TB 126
106 11
107 11
108 11
109 11
110-TB 11
111 11
112-TB 11
113-TB 11
114 11
115-TB 11
1210C 42
1211C 42
1212C 42
1213C 42
1214TB 42
CONFITMRO_EN_ALL.pdf 167 11/28/2011 11:05:50 AM
Alphanumeric Index
Catalogue Page Catalogue Page Catalogue Page
Number Number Number Number Number Number
168
1215TB 42
1216TB 42
122 16
1222 16
1223 16
1224 16
1225 16
1226 16
1227 16
1228 16
1229 16
122AL 16
123 16
1230 16
1231 16
1232 16
123AL 16
124 16
1244 39
1245 39
1246 39
1247 39
124AL 16
125-TB 16
1250-TB 39
1251 39
1252 39
1253 39
1254 39
1255 39
1256 39
1257 39
1258 39
125AL 16
126 16
1261 39
1262 39
1263 39
126AL 16
127 16
1275 41
1275AL 41
1275CR 42
1276 41
1276AL 41
1276CR 42
1277 41
1277AL 41
1277CR 42
1278 41
1278AL 41
1278CR 42
1279 41
1279AL 41
1279CR 42
127AL 16
128 16
1280 41
1280AL 41
1280CR 42
1281 41
1281AL 41
1281CR 42
1282 41, 59
1282AL 41
1283 41, 59
1283AL 41
1284 41, 59
1284AL 41
1285 41, 59
1285AL 41
1286 41
1286AL 41
1287 41
1287AL 41
1288 41
1288AL 41
128AL 16
129 16
129AL 16
12GR-TB 97
130-TB 16
130AL 16
131-TB 16
131AL 16
132-TB 16
133-TB 16
133AL 16
134-TB 16
1341 87
1344 87
1345 87
1346 87
1347 87
134AL 16
1350 44, 59
1350AL 44
1350CR 44
1351 44, 59
1351AL 44
1351CR 44
1352 44, 59
1352AL 44
1352CR 44
1353 44, 59
1353AL 44
1353CR 44
1354 44, 59
1354AL 44
1354CR 44
139 11
140 11
141 11
141AL 11
141SL 11
141SST 11
142-TB 11
142AL 11
142SL 11
142SST 11
143 11
143AL 11
143SL 11
143SST 11
144 11
1440 39
1441 39
1442 39
1443 39
144AL 11
144SL 11
144SST 11
145 11
1451 20
1452 20
1453 20
1454 20
1455 20
1456 20
145AL 11
145SL 11
145SST 11
146-TB 11
1460 21
1461 21
1462 21
1463 21
1464 21
1465 21
146AL 11
146SL 11
146SST 11
147 11
147AL 11
147SST 11
1470-TB 21
1471 21
1472 21
1473 21
CONFITMRO_EN_ALL.pdf 168 11/28/2011 11:05:50 AM
Catalogue Page Catalogue Page Catalogue Page
Number Number Number Number Number Number
Alphanumeric Index
169
1474 21
1475 21
1476 21
1477 21
1478 21
1479 21
148 11
148AL 11
148SST 11
149 11
149AL 11
149SST 11
150 11
150AL 11
150SST 11
151 11
151AL 11
151SST 11
152 11
152AL 11
152SST 11
153 11
153AL 11
153SST 11
1942 23
1943 23
1944 23
1945 23
1946 23
1947 23
1948 23
1949 23
1950 23
1951 23
1953 23
1954 23
1GR-TB 97
2111 86
2116 86
2200 68
2201 68
2202 68
2203 68
2204 68
2205 68
2206-TB 68
2207-TB 68
2208-TB 68
2209 68
2210 68
2211 68
2213 68
2214 68
2215 68
2216 68
2217 68
2218 68
2219 68
222-TB 17
2220-TB 68
2221 68
2222 68
2223 68
223-TB 17
2232 86
2233 86
2234 86
2237 86
2238 86
2239 86
224 17
225-TB 17
2250 67
2251 67
2252 67
2253 67
2254 67
2255 67
2256 67
2257 67
2258 67
226 17
2267 67
2268 67
2269 67
227 17
2270 67
2271 67
2272 67
2273 67
2274 67
2275 67
2276 67
2277 67
2278 67
2279 67
228-TB 17
2280 67
2281 67
2282 67
2283 67
2284 67
2285 67
2286 67
229-TB 17
230-TB 17
231 17
232 17
233 17
234 17
2432 86
2433 86
2434 86
2438 86
2439 86
2442 86
2443 86
2446 86
2447 86
2448 86
2449 86
2450 86
2454 86
249 117
2516 66
2517 66
2518 66
2519 66
252 117
2520 66
2520-2 69
2521 66
2522 66
2523 66
2524 66
2525 66
253-TB 117
2530-2 69
2530 66
2531 66
2531-2 69
2531-3 69
2532 66
2534 66
2535 66
2536 66
254-C 117
2540-3 69
2540-4 69
2541-2 69
2541-3 69
2541 66
2542 66
2542-2 69
2544 66
2545 66
2546 66
2547 66
2548 66
CONFITMRO_EN_ALL.pdf 169 11/28/2011 11:05:50 AM
Alphanumeric Index
Catalogue Page Catalogue Page Catalogue Page
Number Number Number Number Number Number
170
2549 66
255 117
2555-2 69
2556 66
2557 66
2558 66
2559 66
256 117
2562 66
2563 66
2564 66
2565 66
257 117
2573 66
2574 66
2575 66
2576 66
2577 66
258 117
2584 66
2585 66
2586 66
2587 66
259 117
2592 66
2593 66
2594 66
2595 66
2596 66
2631 69
2632 69
2633 69
2634 69
2637 69
2638 69
2639 69
2640 69
2641 69
265 117
266-C 117
267 117
2671 63, 79
2672 79
2673 79
2674 79
2675 79
2676 79
2677 79
2678 63, 79
268-C 117
2680 63, 79
2681 79
2682 79
2683 79
2684 79
2685 63, 79
2686 63, 79
2687 63, 79
2688 63, 79
269 117
2690 79
2691 79
2692 79
2693 79
2694 79
2696 63, 79
2699 63, 79
270 117
2702 63, 79
2703 63, 79
2704 63, 79
2705 63
2705TB 79
2706 63, 79
2707 63, 79
2708 63, 79
2709 63, 79
2710 63, 79
272 117
273-TB 117
274 117
275 117
276 117
277 117
279 117
2827 87
2828 87
2829 87
291-C 118
2918SST 73
2919SST 73
2920 70
2920AL 72
2920NM 63, 75
2920S 70
2920SST 73
2921 70
2921AL 72
2921NM 63, 75
2921S 70
2921SST 73
2922 70
2922AL 72
2922NM 63, 75
2922S 70
2922SST 73
2930 70
2930AL 72
2930NM 63, 75
2930S 70
2930SST 73
2931 70
2931AL 72
2931NM 63, 75
2931S 70
2931SST 73
2932 70
2932AL 72
2932NM 63, 75
2932S 70
2932SST 73
2940 70
2940AL 72
2940NM 63, 75
2940S 70
2940SST 73
2941 70
2941AL 72
2941NM 63, 75
2941S 70
2941SST 73
2942 70
2942AL 72
2942NM 63, 75
2942S 70
2942SST 73
300-TBC 115
302-C 115
304 115
306 115
308 115
310 115
3110-C 115
3112 115
3115 115
3117 115
3118 115
3119 115
312 115
3120 115
3121 115
3122 115
3123 115
3124 115
3125 115
3130-C 116
3132 116
3135 116
3137 116
CONFITMRO_EN_ALL.pdf 170 11/28/2011 11:05:50 AM
Catalogue Page Catalogue Page Catalogue Page
Number Number Number Number Number Number
Alphanumeric Index
171
3138 116
3139 116
314 115
3140 116
3141 116
3142 116
3143 116
3144-TB 116
316 115
3201 124
3202 124, 125
321-C 116
3210 19
3211 19
3212 19
3213 19
3214 19
3215 19
323 116
325 116
326-TB 116
327 116
328 116
329 116
330-TB 116
3300 124, 125
3301-C 118
3302 123
3302M-C 123
3303-C 123
3303M 123
3304 123
3304M 123
3305 123
3305M 123
3306 123
3306M 123
3307 123
3307M 123
3308 123
3309 123
331 116
3310 123
3311 123
3312-C 118
3321 99
3322 99
3323 99
3324 99
3325 99
3326 99
3327 99
3328-TB 99
3329 99
3331 99
3341 99
3342 99
3343 99
3344-TB 99
3345 99
3346 99
3347 99
3348-TB 99
3349 99
3350 124, 125
3352 99
3361 99
3362 99
3363 99
3364 99
3365 99
3366 99
3367 99
3368 99
3369 99
3371 99
34GR-TB 97
3650 12
3651 12
3652 12
3653 12
3654 12
3655 12
3656 12
3657 12
3658 12
3659 12
3661 12
3662 12
370 26
370AL 26
3700 40
3701 40
3702 40
3703 40
3704 40
3705-TB 40
3706 40
3707 40
3708 40
3709 40
371 26
371AL 26
3710 40
3711 40
3712 40
3713 40
3714 40
3715-TB 40
3716 40
3717 40
3718 40
372 26
372AL 26
3720-TB 102
3721-TB 102
3722-TB 102
3723 102
3724-TB 102
3725 102
3726 102
373 26
373AL 26
3730-TB 103
3731-TB 103
3732 103
3733-TB 103
3734-TB 103
3735-TB 103
3736 103
374 26
374AL 26
3740 103
3741 103
3742 103
3743-TB 103
3744-TB 103
3745 103
3746-TB 103
375 26
375AL 26
376 26
377 26
378 26
379-TB 26
381-TB 26
382-TB 26
3861 15
3862 15
3863 15
3864 15
3865 15
3866 15
3870-TB 15
3871-TB 15
3872 15
3873 15
3874 15
3875 15
CONFITMRO_EN_ALL.pdf 171 11/28/2011 11:05:50 AM
Alphanumeric Index
Catalogue Page Catalogue Page Catalogue Page
Number Number Number Number Number Number
172
3876 15
3877 15
3878 15
3879 15
3880 15
3881 15
3882 15
3883 15
3884 15
3886 15
3887 15
3889 15
38GR-TB 97
390 119
391 119
392 119
393 119
394 119
3993 15
3994 15
3995 15
3996 15
3998 15
3999 15
4-250TC 78
4-300TC 78
4-350TC 78
4-400TC 78
401 26
402 26
403-TB 26
404-TB 26
405-TB 26
407 26
408 26
409 26
41TB 100
410-TB 26
4159C 59
4160C 59
4161C 59
4162 59
4163 59
4164 59
4176 59
4177 59
4178 59
4179 59
4180 59
4181 59
42TB 100
422 19
423 19
4230 58
4231 58
4232 58
4233 58
4234 58
4235 58
424 19
4240 58
4241-TB 58
4242 58
4243-TB 58
4244 58
4245 58
425 19
4250 37
4251 37
4252 37
4253 37
4254 37
4255 37
426-TB 19
427-TB 19
428-TB 19
429 19
4290 37
4291 37
4292 37
4293 37
4294 37
4295 37
430-TB 20
431 19
433 19
434 19
440-C 45
441 45
442 45
449C 119
460TB 37
461TB 37
462 37
463 37
485 27
486 27
487 27
488 27
489 27
490 27
491 27
492 27
4920 71
4921 71
4922 71
493 27
4932 71
4933 71
494 27
4960 71
4960AL 72
4960NM 63, 75
4961 71
4961AL 72
4961NM 63, 75
4962 71
4962AL 72
4970 71
4970AL 72
4970NM 63, 75
4971 71
4971AL 72
4971NM 63, 75
4972 71
4972AL 72
4972NM 63, 75
4980AL 72
4981AL 72
4982AL 72
503-TB 118
504 118
505-TB 118
5120 57
5121-TB 57
5123 57
5220 57
5221 57
5223 57
5229 92
5231 92
5231AL 92
5231ALGR 96
5231GR 96
5232 92
5232AL 92
5232ALGR 96
5232GR 96
5233 92
5233AL 92
5233ALGR 96
5233GR 96
5234 92
5234AL 92
5234ALGR 96
5234GR 96
5235 92
5235AL 92
5235GR 96
CONFITMRO_EN_ALL.pdf 172 11/28/2011 11:05:50 AM
Catalogue Page Catalogue Page Catalogue Page
Number Number Number Number Number Number
Alphanumeric Index
173
5236 92
5236AL 92
5236GR 96
5237 92
5237AL 92
5237GR 96
5238 92
5238AL 92
5238GR 96
5239 92
5239AL 92
5239GR 96
5240 92
5240AL 92
5240GR 96
5241 92
5241GR 96
5242 92
5242GR 96
5243 92
5243GR 96
5244 92
5244GR 96
5245 92
5245GR 96
5246 92
5246GR 96
5247 92
5247GR 96
5248 92
5248GR 96
5249 92
5249GR 96
5250 92
5250GR 96
5251 93
5251AL 93
5251ALGR 96
5251GR 96
5252 93
5252AL 93
5252ALGR 96
5252GR 96
5253 93
5253AL 93
5253ALGR 96
5253GR 96
5254 93
5254AL 93
5254ALGR 96
5254GR 96
5255 93
5255AL 93
5255GR 96
5256 93
5256AL 93
5256GR 96
5257 93
5257AL 93
5257GR 96
5258 93
5258AL 93
5258GR 96
5259 93
5259GR 96
5260 93
5260GR 96
5261 74-104
5262 74-104
5263 74-104
5264 74-104
5265 74-104
5266 74-104
5267 74-104
5268 104
5269 104
5270 104
5271 94
5271GR 97
5272 94
5272GR 97
5273 94
5273GR 97
5274 94
5274GR 97
5275 94
5275GR 97
5276 94
5276GR 97
5285 92
5285GR 96
5299 104
530-TB 58
5302 12
5303 12
5304 12
5305 12
5306 12
5307 12
5308 12
5309 12
531 58
5311 12
532 58
5320 57
5321 57
5323 57
5330 92
5331 92
5331-HT 91
5331GR 96
5331SST 74
5332 92
5332-HT 91
5332GR 96
5332SST 74
5333 92
5333-HT 91
5333GR 96
5333SST 74
5334 92
5334-HT 91
5334GR 96
5334SST 74
5335 92
5335-HT 91
5335GR 96
5335SST 74
5336 92
5336-HT 91
5336GR 96
5336SST 74
5337 92
5337-HT 91
5337GR 96
5337SST 74
5338 92
5338-HT 91
5338GR 96
5339 92
5339-HT 91
5339GR 96
5340 92
5340-HT 91
5340GR 96
5341 92
5341GR 96
5341-HT 91
5341SST 74
5342 92
5342GR 96
5342-HT 91
5342SST 74
5343 92
5343GR 96
5343-HT 91
5343SST 74
5344 92
5344GR 96
CONFITMRO_EN_ALL.pdf 173 11/28/2011 11:05:50 AM
Alphanumeric Index
Catalogue Page Catalogue Page Catalogue Page
Number Number Number Number Number Number
174
5344-HT 91
5344SST 74
5345 92
5345GR 96
5345-HT 91
5345SST 74
5346 92
5346GR 96
5346-HT 91
5346SST 74
5347 92
5347GR 96
5347-HT 91
5347SST 74
5348 92
5348GR 96
5349 92
5349GR 96
5350 92
5350GR 96
5351 93
5351GR 96
5351-HT 91
5351SST 74
5352 93
5352GR 96
5352-HT 91
5352SST 74
5353 93
5353GR 96
5353-HT 91
5353SST 74
5354 93
5354GR 96
5354-HT 91
5354SST 74
5355 93
5355GR 96
5355-HT 91
5355SST 74
5356 93
5356GR 96
5356-HT 91
5356SST 74
5357 93
5357GR 96
5357-HT 91
5357SST 74
5358 93
5358GR 96
5359 93
5359GR 96
5360 93
5360GR 96
5361 94
5362 94
5363 94
5364 94
5365 94
5366 94
5367 94
5368 94
5369 94
5370 94
5385 92
5385GR 96
5386 92
5386GR 96
5420 57
5421 57
5423 57
5520 57
5521-TB 57
5523 57
5620 57
5621 57
5623 57
5710 103
5711 103
5712 103
5713 103
5714 103
5715 103
5716 103
5717 103
5718 103
586 16
587 16
600-TB 40
600AL-TB 40
601-TB 40
601AL-TB 40
602-TB 40
602AL-TB 40
603-TB 40
603AL-TB 40
604-TB 40
604AL-TB 40
605-TB 40
605AL 40
606-TB 40
606AL 40
607 40
607AL 40
608 40
608AL 40
609 40
609AL 40
610 40
610AL 40
611-TB 40
611AL 40
612 40
612AL 40
613 40
613AL 40
614-TB 40
614AL 40
615-TB 40
615AL 40
6209 126
6210 126
6211 126
6212 126
6214 126
6216 126
6218 126
6302 102
6303 102
6304 102
6305 102
6322 102
6323 102
6324 102
6325 102
65C 119
674 38
675 38
675AL 38
676 38
676AL 38
677 38
677AL 38
678 38
678AL 38
679 38
679AL 38
680-TB 38
680AL 38
681 38
681AL 38
682 38
682AL 38
683 38
683AL 38
684 38
684AL 38
685 38
685AL 38
CONFITMRO_EN_ALL.pdf 174 11/28/2011 11:05:50 AM
Catalogue Page Catalogue Page Catalogue Page
Number Number Number Number Number Number
Alphanumeric Index
175
686 38
686AL 38
687 38
687AL 38
690TB 45
691TB 45
692TB 45
693TB 45
700TB 45
703 45
7330 105
7341 105
7342 105
7343 105
7344-TB 105
7345 105
7346 105
7347 105
7348-TB 105
7351 105
7352 105
7353 105
7354 105
7355 105
7356 105
7357 105
7358 105
7360 105
7361 105
7362 105
7363 105
7364 105
7365 105
7366 105
7367 105
7368 105
8120 33
8121 33
8123 33
8124 36
8125 36
8130 34
8131 34
8132 34
8134 34
815-TB 20
816 20
817 20
818 20
819 20
820 20
821 20
822 20
8220 33
8221 33
8223 33
8224-TB 36
8225 36
823 22
824 20
8320 33
8321 33
8323 33
8324-TB 36
8325 36
841TB 22
8420 33
8421 33
8423 33
8424 36
8425 36
842ALTB 22
842TB 22
843ALTB 22
843TB 22
844 22
844AL 22
845 22
845AL 22
846 22
846AL 22
847 22
847AL 22
848 22
848AL 22
849 22
849AL 22
850 22
850AL 22
851 22
851AL 22
8520 33
8521 33
8523 33
8524 36
8525-TB 36
853 22
853AL 22
854 22
854AL 22
8620 33
8621 33
8623 33
8624 36
8625 36
8720 33
8721 33
8723-TB 33
8724-TB 36
8725-TB 36
8820 33
8821 33
8823-TB 33
8824-TB 36
8825 36
8850 33
8851 33
8853 33
8854 36
8855 36
8970 33
8971 33
8973 33
8974 36
8975 36
9306 106
9330 106
9331 106
9340 106
9341 106
9342 106
9343TB 106
9344 106
9350 106
9351 106
9352TB 106
9353TB 106
9354TB 106
9360 106
9361 106
9362 106
9363 106
9364 106
CONFITMRO_EN_ALL.pdf 175 11/28/2011 11:05:50 AM
176
Notes
CONFITMRO_EN_ALL.pdf 176 11/28/2011 11:05:50 AM