Type S Contactors and Starters Class 8536/8502/8736/8702/8810/8811/8812 CONTENTS Description Page Magnetic Contactors and Starters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Reversing Magnetic Starters and Contactors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 Motor Starters Multi-Speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39 Contents SECTION 1 – MAGNETIC CONTACTORS AND STARTERS Application Data – Class 8502, 8536 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3 Selection – Class 8502 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-7 Selection – Class 8536 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-12 Application Data – Class 8502, 8536 . . . . . . . . . . . . . . . . . . . . . . . . . . 13-16 Approximate Dimensions, Shipping Weights – Class 8502, 8536 . . . . 17-22 Application Data – Class 8502 Vacuum Contactors. . . . . . . . . . . . . . . . . . 23 Selection and Pricing – Class 8502 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 1 5/98 © 1998 Square D All Rights Reserved Full Voltage Contactors and Starters — NEMA Application Data – Class 8502, 8536 Type SCO2 Size 1, 3-Pole Contactor Type SCO3 Size 1, 3-Pole Starter AC MAGNETIC CONTACTORS CLASS 8502 AC MAGNETIC STARTERS CLASS 8536 General Information General Information Class 8502 Type S magnetic contactors are used to switch heating loads, capacitors, transformers, and electric motors where overload protection is separately provided. Class 8502 contactors are available in NEMA Sizes 00-7. Type S contactors are designed for operation at 600 Volts, AC 50-60 Hertz. Class 8536 Type S magnetic starters are used for full voltage starting and stopping AC squirrel cage motors. Motor overload protection is provided by melting alloy type thermal overload relays. Class 8536 starters are available in NEMA Sizes 00-7. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz. Holding Circuit Contact Holding Circuit Contact A normally open holding circuit contact for three wire control is provided on all contactors as standard. Sizes 00-2 contactors use a Class 9999 SX11 auxiliary contact as the holding circuit contact. Sizes 3-7 contactors use a Class 9999 SX6 auxiliary contact as the holding circuit contact. See Class 9999 for the holding circuit contact electrical ratings. On Size 00-1 single phase contactors, a power pole is used as the holding circuit contact and therefore has the same rating as the power contacts. A normally open holding circuit contact for three wire control is provided on all contactors as standard. Sizes 00-2 contactors use a Class 9999 SX11 auxiliary contact as the holding circuit contact. Sizes 3-7 contactors use a Class 9999 SX6 auxiliary contact as the holding circuit contact. See Class 9999 for the holding circuit contact electrical ratings. Enclosures Class 8502 magnetic contactors are available in the following enclosures: Starter with MOTOR LOGIC • NEMA Type 1 General Purpose • NEMA Type 4 & 4X Watertight and Dusttight Stainless Steel • NEMA Type 4X Watertight, Dusttight, and Corrosion Resistant Glass — Polyester • NEMA Type 7 & 9 Bolted and Spin-Top for Hazardous Locations • NEMA Type 12 Dusttight and Driptight for Industrial Use The NEMA Type 4 & 4X stainless steel enclosure (Sizes 0-5) has a brushed finish. For an electropolished finish, specify Form G16 and add 15% to the price of the standard device. Also, NEMA Type 12 devices are available UL Listed for use in Class II, Division 2, Group G and Class III, Divisions 1 and 2 locations. Request Form G21, no additional charge. Starter with Melting Alloy Separate enclosures are available, see Class 9991. Overload Relays with Melting Alloys Class 8536 Type S Sizes 00-6 starters are provided with a melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip (Class 20) Sizes 00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3. Single-phase starters use one thermal unit, 3-phase starters use three thermal units. Class 8536 Size 7 starters are provided with solid state Motor Logic which has selectable trip Class10/20, Ground fault detection, and Communication capabilities for future enhancement. The solid state overload relay is ambient insensitive and features phase loss, phase unbalance and over-current protection. MOTOR LOGIC™ Solid State Overload Relay (SSOLR) Solid state overload relays are available for Sizes 00 – 7 starters. These ambient insensitive overload relays provide phase loss protection, phase unbalance protection and a LED power indicator. For additional information, see the Class 9065 catalog section. To order Type S starters with solid state overload relays, see Factory Modification (FORMS). Bimetallic overload relays are also available for Sizes 0-6. Ambient Compensated and Noncompensated versions are supplied with manual 2 © 1998 Square D All Rights Reserved 5/98 Full Voltage Contactors and Starters — NEMA Application Data – Class 8502, 8536 and automatic reset, trip current adjustment, and an alarm contact on Sizes 0-2. For additional information, see the Class 9065 catalog section. To order Type S starters with bimetallic overload relays, see Factory Modifications (FORMS). Enclosures Class 8536 magnetic starters are available in the following enclosures. • NEMA Type 1 General Purpose Enclosure • NEMA Type 3R Rainproof, Sleet Resistant for Outdoor Use • NEMA Type 4 & 4X Watertight and Dusttight • NEMA Type 4X Watertight, Dusttight, and Corrosion Resistant Glass – Polyester • NEMA Type 7 & 9 Bolted and Spin-Top for Hazardous Locations • NEMA Type 9 Bolted for Hazardous Locations • NEMA Type 12 Dusttight and Driptight for Industrial Use The NEMA Type 4 & 4X stainless steel enclosure (Sizes 0-5) has a brushed finish. For an electropolished finish, specify Form G16 and add 15% to the price of the standard device. Sizes 6 & 7 are painted sheet steel and are rated NEMA 4 ONLY. Also NEMA Type 12 devices are available UL Listed for use in Class II, Division 2, Group G and Class III, Divisions 1 and 2 locations. Specify Form G21, no additional charge. Coil Voltages AC coils are available for application on 50-60 Hertz. NEMA Sizes 00-5 are supplied with coils that are designed to operate satisfactorily on line voltages of 85% – 110% of rated voltage. NEMA Size 6 and 7 contactors are supplied with a DC coil operated by a solid state rectifier circuit that is powered by an AC source. Please note that Voltage Codes have been added to the Type designations in order to improve customer service. It is necessary to include the Voltage Code when ordering contactors and starters. Also, 120 Volt Polyphase contactors and starters will be wired for separate control. Auxiliary Contacts Additional auxiliary contacts may be added to Type S contactors. See Page 15 for maximum number of auxiliary units and Form designations for factory installed auxiliary contacts. Type S Accessories Additional accessories such as power poles, pneumatic timer attachments, and cover mounted control stations are available as factory or field modifications. Separate enclosures are available, see Class 9991. 3 5/98 © 1998 Square D All Rights Reserved Full Voltage Contactors — NEMA Selection – Class 8502 3-Pole Polyphase — 600 Volts AC Maximum — 50-60 Hertz Continuous Current Ratings Motor Volts 00 9 Separate Controlj 200 230 460 575 0 18 1 2 NEMA Size Type SC02 Size 1, 3-Pole Contactor Max. HP t Coil Voltage Open Type NEMA Type 1 General Purpose Enclosure NEMA Type 4 & 4X Watertight, Dusttight Brushed Stainless Steel Enclosure (Size 0-5)f Type Type Type 11⁄2 11⁄2 2 2 120 208 240 480 600 SAO12V02S SAO12V08 SAO12V03 SAO12V06 SAO12V07 SAG12V02S SAG12V08 SAG12V03 SAG12V06 SAG12V07 USE Size 0 Separate Controlj 200 230 460 575 3 3 5 5 120 208 240 480 600 SBO2V02S SBO2V08 SBO2V03 SBO2V06 SBO2V07 SBG2V02S SBG2V08 SBG2V03 SBG2V06 SBG2V07 SBW12V02S SBW12V08 SBW12V03 SBW12V06 SBW12V07 27 Separate Controlj 200 230 460 575 71⁄2 71⁄2 10 10 120 208 240 480 600 SCO2V02S SCO2V08 SCO2V03 SCO2V06 SCO2V07 SCG2V02S SCG2V08 SCG2V03 SCG2V06 SCG2V07 SCW12V02S SCW12V08 SCW12V03 SCW12V06 SCW12V07 45 Separate Controlj 200 230 460 575 10 15 25 25 120 208 240 480 600 SDO2V02S SDO2V08 SDO2V03 SDO2V06 SDO2V07 SDG2V02S SDG2V08 SDG2V03 SDG2V06 SDG2V07 SDW12V02S SDW12V08 SDW12V03 SDW12V06 SDW12V07 3 90 Separate Controlj 200 230 460 575 25 30 50 50 120 208 240 480 600 SEO2V02S SEO2V08 SEO2V03 SEO2V06 SEO2V07 SEG2V02S SEG2V08 SEG2V03 SEG2V06 SEG2V07 SEW12V02S SEW12V08 SEW12V03 SEW12V06 SEW12V07 4 135 Separate Controlj 200 230 460 575 40 50 100 100 120 208 240 480 600 SFO2V02S SFO2V08 SFO2V03 SFO2V06 SFO2V07 SFG2V02S SFG2V08 SFG2V03 SFG2V06 SFG2V07 SFW12V02S SFW12V08 SFW12V03 SFW12V06 SFW12V07 5 270 Separate Controlj 200 230 460 575 75 100 200 200 120 208 240 480 600 SGO2V02S SGO2V08 SGO2V03 SGO2V06 SGO2V07 SGG2V02S SGG2V08 SGG2V03 SGG2V06 SGG2V07 SGW12V02S SGW12V08 SGW12V03 SGW12V06 SGW12V07 6 540 Separate Controlj 200 230 460 575 150 200 400 400 120 208 240 480 600 SHO2V02S SHO2V08 SHO2V03 SHO2V06 SHO2V07 SHG2V02S SHG2V08 SHG2V03 SHG2V06 SHG2V07 SHW12V02S SHW12V08 SHW12V03 SHW12V06 SHW12V07 810 Separate Controlj 200 230 460 575 ... 300 600 600 120 208 240 480 600 SJO2V02S SJO2V08 SJO2V03 SJO2V06 SJO2V07 SJG2V02S SJG2V08 SJG2V03 SJG2V06 SJG2V07 SJW12V02S SJW12V08 SJW12V03 SJW12V06 SJW12V07 7 f j t Size 6 and 7 are painted sheet steel rated NEMA Type 4 only. 120 Volt Polyphase contactors are wired for separate control. Coil voltage code must be specified to order this product. Refer to standard voltage codes listed below and insert as shown in How to Order. Coil Voltage Codes Voltage Code File E78351 CCN NLDX File LR12751 Class 3211-04 60 Hz 50 Hz 24q 120 208 240 480 600 Specify ... 110 ... 220 440 550 Specify q VO1 VO2 VO8 VO3 VO6 VO7 V99 24 V coils are not available on Sizes 4-7. On Sizes 00-3, where 24 V coils are available, Form S (separate control) must be specified. How to Order: To Order Specify: File 60905 Class 3211-04 IEC 947-4-1 Sizes 00-5 only • Class Number • Type Number • Coil Voltage Code • Form(s) Catalog Number Class Type Coil Voltage Code Form(s) 8502 SBG2 VO2 P1S Factory Modifications (FORMS) ...............Refer to Catalog 9999CT9701 Application Data ................................................................... Pages 13-16 Dimensions ........................................................................... Pages 17-20 Separate Enclosures (Class 9991) ...........Refer to Catalog 9999CT9701 Replacement Parts (Class 9998) ..............Refer to Catalog 9999CT9701 Type S Accessories (Class 9999) .............Refer to Catalog 9999CT9701 4 © 1998 Square D All Rights Reserved 5/98 Full Voltage Contactors — NEMA Selection – Class 8502 3-Pole Polyphase — 600 Volts AC Maximum — 50-60 Hertz Continuous Current Ratings NEMA Size Motor Volts Max. HP t Coil Voltage NEMA Type 4X Watertight, Dusttight, Corrosion-Resistant Glass-Polyester Enclosure NEMA Type 7 & 9 Hazardous Locations Class I, Groups C & D Class II, Groups E, F, & G Bolted Type Type Cast Ironc Cast Aluminum NEMA Type 12 Dusttight & Driptight Industrial Use Enclosure SPIN TOP ® Type Type Use Size 0 Use Size 0 00 9 Separate Controlj 200 11⁄2 230 11⁄2 460 2 575 2 120 208 240 480 600 Use Size 0 Use Size 0 0 18 Separate Controlj 200 3 230 3 460 5 575 5 120 208 240 480 600 SBW22V02S SBW22V08 SBW22V03 SBW22V06 SBW22V07 SBT2V02S SBT2V08 SBT2V03 SBT2V06 SBT2V07 SBT42V02S SBT42V08 SBT42V03 SBT42V06 SBT42V07 SBR2V02S SBR2V08 SBR2V03 SBR2V06 SBR2V07 SBA2V02S SBA2V08 SBA2V03 SBA2V06 SBA2V07 1 27 Separate Controlj 200 71⁄2 230 71⁄2 460 10 575 10 120 208 240 480 600 SCW22V02S SCW22V08 SCW22V03 SCW22V06 SCW22V07 SCT2V02S SCT2V08 SCT2V03 SCT2V06 SCT2V07 SCT42V02S SCT42V08 SCT42V03 SCT42V06 SCT42V07 SCR2V02S SCR2V08 SCR2V03 SCR2V06 SCR2V07 SCA2V02S SCA2V08 SCA2V03 SCA2V06 SCA2V07 2 45 Separate Controlj 200 10 230 15 460 25 575 25 120 208 240 480 600 SDW22V02S SDW22V08 SDW22V03 SDW22V06 SDW22V07 SDT2V02S SDT2V08 SDT2V03 SDT2V06 SDT2V07 SDT42V02S SDT42V08 SDT42V03 SDT42V06 SDT42V07 SDR2V02S SDR2V08 SDR2V03 SDR2V06 SDR2V07 SDA2V02S SDA2V08 SDA2V03 SDA2V06 SDA2V07 3 90 Separate Controlj 200 25 230 30 460 50 575 50 120 208 240 480 600 SEW22V02S SEW22V08 SEW22V03 SEW22V06 SEW22V07 ... SET42V02S SET42V08 SET42V03 SET42V06 SET42V07 SER2V02S SER2V08 SER2V03 SER2V06 SER2V07 SEA2V02S SEA2V08 SEA2V03 SEA2V06 SEA2V07 4 135 Separate Controlj 200 40 230 50 460 100 575 100 120 208 240 480 600 SFW22V02S SFW22V08 SFW22V03 SFW22V06 SFW22V07 ... SFT42V02S SFT42V08 SFT42V03 SFT42V06 SFT42V07 SFR2V02S SFR2V08 SFR2V03 SFR2V06 SFR2V07 SFA2V02S SFA2V08 SFA2V03 SFA2V06 SFA2V07 5 270 Separate Controlj 200 75 230 100 460 200 575 200 120 208 240 480 600 ... ... ... SGR2V02S SGR2V08 SGR2V03 SGR2V06 SGR2V07 SGA2V02S SGA2V08 SGA2V03 SGA2V06 SGA2V07 6 540 Separate Controlj 200 150 230 200 460 400 575 400 120 208 240 480 600 ... ... ... ... SHA2V02S SHA2V08 SHA2V03 SHA2V06 SHA2V07 7 810 Separate Controlj 200 — 230 300 460 600 575 600 208 240 480 600 ... ... ... ... SJA2V02S SJA2V08 SJA2V03 SJA2V06 SJA2V07 j c t 120 Volt Polyphase contactors are wired for separate control. Limited to one Pilot Light and a Selector Switch or Start-Stop Push Button. Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed in selection table above or additional standard voltage codes below and insert as shown in the HOW TO ORDER block. Coil Voltage Codes Explosion Proof Units Voltage File E78503 CCN NPKR Code 60 Hz 50 Hz 24q 120 208 240 480 600 Specify ... 110 ... 220 440 550 Specify q VO1 VO2 VO8 VO3 VO6 VO7 V99 File LR60905 Class 3218-03 24 V coils are not available on Sizes 4-7. On Sizes 00-3, where 24 V coils are available, Form S (separate control) must be specified. How to Order: To Order Specify: Factory Modifications (FORMS) ............... Refer to Catalog 9999CT9701 Application Data .................................................................... Pages 13-16 Dimensions ............................................................................ Pages 17-20 Separate Enclosures (Class 9991) ........... Refer to Catalog 9999CT9701 Replacement Parts (Class 9998) .............. Refer to Catalog 9999CT9701 Type S Accessories (Class 9999) ............ Refer to Catalog 9999CT9701 • Class Number • Type Number • Coil Voltage Code • Form(s) Catalog Number Class Type Coil Voltage Code Form(s) 8502 SBA2 VO2 P1S 5 5/98 © 1998 Square D All Rights Reserved Full Voltage Contactors — NEMA Selection – Class 8502 600 Volts AC Maximum — 50-60 Hertz NEMA Size Continuous Current Ratings Motor Volts Max. HP t Coil Voltage Open Type NEMA Type 1 General Purpose Enclosure Type Type NEMA Type 4 & 4X Watertight, Dusttight Brushed Stainless Steel Enclosure (Size 0-5)f Type 1-Pole Single Phase 0 18 1 27 115 230 115 230 1 2 2 3 120 240 120 240 SBO5V02 SBO5V03 SCO5V02 SCO5V03 SBG5V02 SBG5V03 SCG5V02 SCG5V03 SBW15V02 SBW15V03 SCW15V02 SCW15V03 1⁄3 120 240 120 240 120 240 120 240 120 240 120 240 120 240 120 240 120 240 SAO11V02 SAO11V03 SBO1V02 SBO1V03 SCO1V02 SCO1V03 SDO1V02 SDO1V03 SEO1V02 SEO1V03 SFO1V02 SFO1V03 SGO1V02 SGO1V03 SHO1V02 SHO1V03 SJO1V02 SJO1V03 SAG11V02 SAG11V03 SBG1V02 SBG1V03 SCG1V02 SCG1V03 SDG1V02 SDG1V03 SEG1V02 SEG1V03 SFG1V02 SFG1V03 SGG1V02 SGG1V03 SHG1V02 SHG1V03 SJG1V02 SJG1V03 Use Size 0 120 208 240 480 600 120 208 240 480 600 120 208 240 480 600 120 208 240 480 600 120 208 240 480 600 SBO3V02S SBO3V08 SBO3V03 SBO3V06 SBO3V07 SCO3V02S SCO3V08 SCO3V03 SCO3V06 SCO3V07 SDO3V02S SDO3V08 SDO3V03 SDO3V06 SDO3V07 SEO3V02S SEO3V08 SEO3V03 SEO3V06 SEO3V07 SFO3V02S SFO3V08 SFO3V03 SFO3V06 SFO3V07 SBG3V02S SBG3V08 SBG3V03 SBG3V06 SBG3V07 SCG3V02S SCG3V08 SCG3V03 SCG3V06 SCG3V07 SDG3V02S SDG3V08 SDG3V03 SDG3V06 SDG3V07 SEG3V02S SEG3V08 SEG3V03 SEG3V06 SEG3V07 SFG3V02S SFG3V08 SFG3V03 SFG3V06 SFG3V07 SBW13V02S SBW13V08 SBW13V03 SBW13V06 SBW13V07 SCW13V02S SCW13V08 SCW13V03 SCW13V06 SCW13V07 SDW13V02S SDW13V08 SDW13V03 SDW13V06 SDW13V07 SEW13V02S SEW13V08 SEW13V03 SEW13V06 SEW13V07 SFW13V02S SFW13V08 SFW13V03 SFW13V06 SFW13V07 2-Pole Single Phase 00 9 0 18 1 27 2 45 115 230 115 230 115 230 115 230 3 90 ... ... 4 135 ... ... 5 270 ... ... 6 540 ... ... 7 810 ... ... 1 1 2 2 3 3 71⁄2 SBW11V02 SBW11V03 SCW11V02 SCW11V03 SDW11V02 SDW11V03 SEW11V02 SEW11V03 SFW11V02 SFW11V03 SGW11V02 SGW11V03 SHW1V02 SHW1V03 SJW1V02 SJW1V03 4-Pole Polyphase 0 18 1 27 2 45 3 90 4 135 Separate Controlj 200 230 460 575 Separate Controlj 200 230 460 575 Separate Controlj 200 230 460 575 Separate Controlj 200 230 460 575 Separate Controlj 200 230 460 575 3 3 5 5 71⁄2 71⁄2 10 10 10 15 25 25 25 30 50 50 40 50 100 100 5-Pole Polyphase 0 1 2 3 4 f j t Separate Controlj 120 SBO4V02S SBG4V02S SBW14V02S 200 3 208 SBO4V08 SBG4V08 SBW14V08 230 3 240 SBO4V03 SBG4V03 SBW14V03 460 5 480 SBO4V06 SBG4V06 SBW14V06 575 5 600 SBO4V07 SBG4V07 SBW14V07 Separate Controlj 120 SCO4V02S SCG4V02S SCW14V02S 1 200 7 ⁄2 208 SCO4V08 SCG4V08 SCW14V08 27 230 71⁄2 240 SCO4V03 SCG4V03 SCW14V03 460 10 480 SCO4V06 SCG4V06 SCW14V06 575 10 600 SCO4V07 SCG4V07 SCW14V07 Separate Controlj 120 SDO4V02S SDG4V02S SDW14V02S 200 10 208 SDO4V08 SDG4V08 SDW14V08 45 230 15 240 SDO4V03 SDG4V03 SDW14V03 460 25 480 SDO4V06 SDG4V06 SDW14V06 575 25 600 SDO4V07 SDG4V07 SDW14V07 Separate Controlj 120 SEO4V02S SEG4V02S SEW14V02S 200 25 208 SEO4V08 SEG4V08 SEW14V08 90 230 30 240 SEO4V03 SEG4V03 SEW14V03 460 50 480 SEO4V06 SEG4V06 SEW14V06 575 50 600 SEO4V07 SEG4V07 SEW14V07 Separate Controlj 120 SFO4V02S SFG4V02S SFW14V02S 200 40 208 SFO4V08 SFG4V08 SFW14V08 135 230 50 240 SFO4V03 SFG4V03 SFW14V03 460 100 480 SFO4V06 SFG4V06 SFW14V06 575 100 600 SFO4V07 SFG4V07 SFW14V07 Size 6 and 7 are painted sheet steel rated NEMA Type 4 only. 120 Volt Polyphase contactors are wired for separate control. Coil voltage code must be specified to order this product. Refer to standard voltage codes listed in selection table above or additional standard voltage codes and insert as shown in the HOW TO ORDER block on Page 5. 18 6 © 1998 Square D All Rights Reserved 5/98 Full Voltage Contactors — NEMA Selection – Class 8502 600 Volts AC Maximum — 50-60 Hertz NEMA Size Continuous Current Ratings Motor Volts Max. HP t Coil Voltage NEMA Type 4X Watertight, Dusttight, Corrosion-Resistant Glass-Polyester Enclosure NEMA Type 7 & 9 Hazardous Locations Class I, Groups C & D Class II, Groups E, F, & G Bolted Type Type Cast Ironc Cast Aluminum ... SBT5V02 SBT5V03 SCT5V02 SCT5V03 SBT45V02 SBT45V03 SCT5V02 SCT5V03 NEMA Type 12 Dusttight & Driptight Industrial Use Enclosure SPIN TOP ® Type Type SBR5V02 SBR5V03 SCR5V02 SCR5V03 SBA5V02 SBA5V03 SCA5V02 SCA5V03 1-Pole Single Phase 0 18 1 27 115 230 115 230 1 2 2 3 120 240 120 240 1/3 1 1 2 2 3 3 71⁄2 120 240 120 240 120 240 120 240 120 240 120 240 120 240 120 240 120 240 Use Size 0 Use Size 0 SBW21V02 SBW21V03 SCW21V02 SCW21V03 SDW21V02 SDW21V03 Consult Local Square D Field Office Consult Local Square D Field Office SBT1V02 SBT1V03 SCT1V02 SCT1V03 SDT1V02 SDT1V03 120 208 240 480 600 120 208 240 480 600 120 208 240 480 600 120 208 240 480 600 120 208 240 480 600 ... 2-Pole Single Phase 0 18 1 27 2 45 115 230 115 230 115 230 115 230 3 90 ... ... 4 135 ... ... 5 270 ... ... 6 540 ... ... 7 810 ... ... 00 9 Use Size 0 Use Size 0 ... SBT41V02 SBT41V03 SCT41V02 SCT41V03 SDT41V02 SDT41V03 SET41V02 SET41V03 SFT41V02 SFT41V03 ... ... ... SBR1V02 SBR1V03 SCR1V02 SCR1V03 SDR1V02 SDR1V03 SER1V02 SER1V03 SFR1V02 SFR1V03 SGR1V02 SGR1V03 ... ... ... ... ... ... ... ... SBA1V02 SBA1V03 SCA1V02 SCA1V03 SDA1V02 SDA1V03 SEA1V02 SEA1V03 SFA1V02 SFA1V03 SGA1V02 SGA1V03 SHA1V02 SHA1V03 SJA1V02 SJA1V03 SBW33V02S SBW33V08 SBW33V03 SBW33V06 SBW33V07 SCW23V02S SCW23V08 SCW23V03 SCW23V06 SCW23V07 SDW23V02S SDW23V08 SDW23V03 SDW23V06 SDW23V07 SBT3V02S SBT3V08 SBT3V03 SBT3V06 SBT3V07 SCT3V02S SCT3V08 SCT3V03 SCT3V06 SCT3V07 SDT3V02S SDT3V08 SDT3V03 SDT3V06 SDT3V07 Consult Local Square D Field Office Consult Local Square D Field Office Consult Local Square D Field Office Consult Local Square D Field Office Consult Local Square D Field Office Consult Local Square D Field Office SBR3V02S SBR3V08 SBR3V03 SBR3V06 SBR3V07 SCR3V02S SCR3V08 SCR3V03 SCR3V06 SCR3V07 SDR3V02S SDR3V08 SDR3V03 SDR3V06 SDR3V07 SER3V02S SER3V08 SER3V03 SER3V06 SER3V07 SFR3V02S SFR3V08 SFR3V03 SFR3V06 SFR3V07 SBA3V02S SBA3V08 SBA3V03 SBA3V06 SBA3V07 SCA3V02S SCA3V08 SCA3V03 SCA3V06 SCA3V07 SDA3V02S SDA3V08 SDA3V03 SDA3V06 SDA3V07 SEA3V02S SEA3V08 SEA3V03 SEA3V06 SEA3V07 SFA3V02S SFA3V08 SFA3V03 SFA3V06 SFA3V07 ... 4-Pole Polyphase 0 18 1 27 2 45 3 90 4 135 Separate Controlj 200 3 230 3 460 5 575 5 Separate Controlj 200 71⁄2 230 71⁄2 460 10 575 19 Separate Controlj 200 10 230 15 460 25 575 25 Separate Controlj 200 25 230 30 460 50 575 50 Separate Controlj 200 40 230 50 460 100 575 100 Consult Local Square D Field Office Consult Local Square D Field Office Consult Local Square D Field Office 5-Pole Polyphase 0 1 2 3 4 j c t Separate Controlj 120 SBA4V02S 200 3 208 SBA4V08 Consult Local Square D 230 3 240 ... ... ... SBA4V03 Field Office 460 5 480 SBA4V06 575 5 600 SBA4V07 Separate Controlj 120 SCA4V02S 1 208 SCA4V08 200 7 ⁄2 Consult Local Square D 230 71⁄2 240 SCA4V03 27 ... ... ... Field Office 460 10 480 SCA4V06 575 10 600 SCA4V07 Separate Controlj 120 SDA4V02S 200 10 208 SDA4V08 Consult Local Square D 45 230 15 240 ... ... ... SDA4V03 Field Office 460 25 480 SDA4V06 575 25 600 SDA4V07 Separate Controlj 120 SEA4V02S 200 25 208 SEA4V08 Consult Local Square D 90 230 30 240 ... ... ... SEA4V03 Field Office 460 50 480 SEA4V06 575 50 600 SEA4V07 Separate Controlj 120 SFA4V02S 200 40 208 SFA4V08 Consult Local Square D 135 230 50 240 ... ... ... SFA4V03 Field Office 460 100 480 SFA4V06 575 100 600 SFA4V07 120 Volt Polyphase contactors are wired for separate control. Limited to one Pilot Light and a Selector Switch or Start-Stop Push Button. Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed in selection table above or additional standard voltage codes and insert as shown in the HOW TO ORDER block on Page 5. 18 7 5/98 © 1998 Square D All Rights Reserved Full Voltage Starters — NEMA Selection – Class 8536 3-Pole Polyphase—600 Volt AC Max. 50/60 Hz—Three Thermal Units Required Continuous Motor NEMA Current Volts Size Ratings Max. HP Open t Type Coil Voltage Type 00 0 1 2 3 4 5 6 7 f j t NEMA Type 1 General Purpose Enclosure Type NEMA Type 4 & 4X Watertight, Dusttight Brushed Stainless Steel Enclosure (Size 0-5)f Type NEMA Type 4X Watertight, Dusttight, Corrosion-Resistant Glass-Polyester Enclosure Type Separate Controlj 120 SAO12V02S SAG12V02S 200 11⁄2 208 SAO12V08 SAG12V08 9 230 11⁄2 240 SAO12V03 SAG12V03 Use Size 0 Use Size 0 460 2 480 SAO12V06 SAG12V06 575 2 600 SAO12V07 SAG12V07 Separate Controlj 120 SBO2V02S SBG2V02S SBW12V02S SBW22V02S 200 3 208 SBO2V08 SBG2V08 SBW12V08 SBW22V08 230 3 240 SBO2V03 SBG2V03 SBW12V03 SBW22V03 18 460 5 480 SBO2V06 SBG2V06 SBW12V06 SBW22V06 575 5 600 SBO2V07 SBG2V07 SBW12V07 SBW22V07 Separate Controlj 120 SCO3V02S SCG3V02S SCW13V02S SCW23V02S 1 200 7 ⁄2 208 SCO3V08 SCG3V08 SCW13V08 SCW23V08 27 230 71⁄2 240 SCO3V03 SCG3V03 SCW13V03 SCW23V03 460 10 480 SCO3V06 SCG3V06 SCW13V06 SCW23V06 575 10 600 SCO3V07 SCG3V07 SCW13V07 SCW23V07 Separate Controlj 120 SDO1V02S SDG1V02S SDW11V02S SDW21V02S 200 10 208 SDO1V08 SDG1V08 SDW11V08 SDW21V08 45 230 15 240 SDO1V03 SDG1V03 SDW11V03 SDW21V03 460 25 480 SDO1V06 SDG1V06 SDW11V06 SDW21V06 575 25 600 SDO1V07 SDG1V07 SDW11V07 SDW21V07 Separate Controlj 120 SEO1V02S SEG1V02S SEW11V02S SEW21V02S 200 25 208 SEO1V08 SEG1V08 SEW11V08 SEW21V08 90 230 30 240 SEO1V03 SEG1V03 SEW11V03 SEW21V03 460 50 480 SEO1V06 SEG1V06 SEW11V06 SEW21V06 575 50 600 SEO1V07 SEG1V07 SEW11V07 SEW21V07 Separate Controlj 120 SFO1V02S SFG1V02S SFW11V02S SFW21V02S 200 40 208 SFO1V08 SFG1V08 SFW11V08 SFW21V08 135 230 50 240 SFO1V03 SFG1V03 SFW11V03 SFW21V03 460 100 480 SFO1V06 SFG1V06 SFW11V06 SFW21V06 575 100 600 SFO1V07 SFG1V07 SFW11V07 SFW21V07 Separate Controlj 120 SGO1V02S SGG1V02S SGW11V02S 200 75 208 SGO1V08 SGG1V08 SGW11V08 270 230 100 240 SGO1V03 SGG1V03 SGW11V03 ... 460 200 480 SGO1V06 SGG1V06 SGW11V06 575 200 600 SGO1V07 SGG1V07 SGW11V07 Separate Controlj 120 SHO2V02S SHG2V02S SHW2V02S 200 150 208 SHO2V08 SHG2V08 SHW2V08 540 230 200 240 SHO2V03 SHG2V03 SHW2V03 ... 460 400 480 SHO2V06 SHG2V06 SHW2V06 575 400 600 SHO2V07 SHG2V07 SHW2V07 Separate Controlj 120 SJO2V02S SJG2V02S SJW2V02S 200 — 208 SJO2V08 SJG2V08 SJW2V08 810 230 300 240 SJO2V03 SJG2V03 SJW2V03 ... 460 600 480 SJO2V06 SJG2V06 SJW2V06 575 600 600 SJO2V07 SJG2V07 SJW2V07 Size 6 and 7 are rated NEMA Type 4 only. 120 Volt Polyphase starters are wired for separate control. Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed in selection table above or additional standard voltage codes below and insert as shown in the HOW TO ORDER block. Coil Voltage Codes Voltage Code 60 Hz 50 Hz 24q 120 208 240 480 600 Specify ... 110 ... 220 440 550 Specify q File E78351 CCN NLDX File LR60905 Class 3211-04 IEC 947-4-1 Sizes 00-5 only VO1 VO2 VO8 VO3 VO6 VO7 V99 24 V coils are not available on Sizes 4-7. On Sizes 00-3, where 24 V coils are available, Form S (separate control) must be specified. How to Order: To Order Specify: • Class Number • Type Number • Coil Voltage Code • Form(s) Catalog Number Class Type Coil Voltage Code Form(s) 8536 SBA2 VO2 P1S Factory Modifications (FORMS) ...............Refer to Catalog 9999CT9701 Application Data ................................................................... Pages 13-16 Dimensions ........................................................................... Pages 17-20 Separate Enclosures (Class 9991) ...........Refer to Catalog 9999CT9701 Replacement Parts (Class 9998) ..............Refer to Catalog 9999CT9701 Type S Accessories (Class 9999) .............Refer to Catalog 9999CT9701 8 © 1998 Square D All Rights Reserved 5/98 Full Voltage Starters — NEMA Selection – Class 8536 3-Pole Polyphase — 600 Volts AC Maximum — 50-60 Hertz—Three Thermal Units Required Continuous Current Ratings NEMA Size Motor Volts Max. HP t Coil Voltage NEMA Type 12/3Rk NEMA Type 9 Dusttight & Driptight Hazardous Locations Industrial Use Class II, Groups E, F, & G Enclosure NEMA Type 7 & 9 Hazardous Locations Class I, Groups C & D Class II, Class E, F, & G Bolted Type Cast Ironc Type Type USE Size 0 USE Size 0 Use Size 0 00 9 0 18 Separate Controlj 200 3 230 3 460 5 575 5 120 208 240 480 600 SBT2V02S SBT2V08 SBT2V03 SBT2V06 SBT2V07 SBT42V02S SBT42V08 SBT42V03 SBT42V06 SBT42V07 SBR2V02S SBR2V08 SBR2V03 SBR2V06 SBR2V07 SBE2V02S SBE2V08 SBE2V03 SBE2V06 SBE2V07 SBA2V02S SBA2V08 SBA2V03 SBA2V06 SBA2V07 1 27 Separate Controlj 200 71⁄2 230 71⁄2 460 10 575 10 120 208 240 480 600 SCT3V02S SCT3V08 SCT3V03 SCT3V06 SCT3V07 SCT43V02S SCT43V08 SCT43V03 SCT43V06 SCT43V07 SCR3V02S SCR3V08 SCR3V03 SCR3V06 SCR3V07 SCE3V02S SCE3V08 SCE3V03 SCE3V06 SCE3V07 SCA3V02S SCA3V08 SCA3V03 SCA3V06 SCA3V07 2 45 Separate Controlj 200 10 230 15 460 25 575 25 120 208 240 480 600 SDT1V02S SDT1V08 SDT1V03 SDT1V06 SDT1V07 SDT41V02S SDT41V08 SDT41V03 SDT41V06 SDT41V07 SDR1V02S SDR1V08 SDR1V03 SDR1V06 SDR1V07 SDE1V02S SDE1V08 SDE1V03 SDE1V06 SDE1V07 SDA1V02S SDA1V08 SDA1V03 SDA1V06 SDA1V07 3 90 Separate Controlj 200 25 230 30 460 50 575 50 120 208 240 480 600 ... SET43V02S SET43V08 SET43V03 SET43V06 SET43V07 SER3V02S SER3V08 SER3V03 SER3V06 SER3V07 SEE1V02S SEE1V08 SEE1V03 SEE1V06 SEE1V07 SEA1V02S SEA1V08 SEA1V03 SEA1V06 SEA1V07 4 135 Separate Controlj 200 40 230 50 460 100 575 100 120 208 240 480 600 ... SFT41V02S SFT41V08 SFT41V03 SFT41V06 SFT41V07 SFR1V02S SFR1V08 SFR1V03 SFR1V06 SFR1V07 SFE1V02S SFE1V08 SFE1V03 SFE1V06 SFE1V07 SFA1V02S SFA1V08 SFA1V03 SFA1V06 SFA1V07 5 270 Separate Controlj 200 75 230 100 460 200 575 200 120 208 240 480 600 ... SGT41V02S SGT41V08 SGT41V03 SGT41V06 SGT41V07 SGR1V02S SGR1V08 SGR1V03 SGR1V06 SGR1V07 SGE1V02S SGE1V08 SGE1V03 SGE1V06 SGE1V07 SGA1V02S SGA1V08 SGA1V03 SGA1V06 SGA1V07 6 540 Separate Controlj 200 150 230 200 460 400 575 400 120 208 240 480 600 ... ... ... ... SHA2V02S SHA2V08 SHA2V03 SHA2V06 SHA2V07 810 Separate Controlj 200 — 230 300 460 600 575 600 120 208 240 480 600 ... SJA2V02S SJA2V08 SJA2V03 SJA2V06 SJA2V07 k j c t USE Size 0 SPIN TOP® Type Separate Controlj 200 11⁄2 230 11⁄2 460 2 575 2 7 120 208 240 480 600 Cast Aluminum ... ... ... For NEMA Type 3R enclosed devices (Sizes 0-4 only), change “A” in Type designation to “H”, no additional charge. Consult Factory for restrictions on available Forms in NEMA Type 3R enclosures. 120 Volt Polyphase starters are wired for separate control. Limited to one Pilot Light and a Selector Switch or Start-Stop Push Button. Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed in selection table above or additional standard voltage codes in table below and insert as shown in the HOW TO ORDER block. Coil Voltage Codes Voltage Code 60 Hz 50 Hz 24q 120 208 240 480 600 Specify ... 110 ... 220 440 550 Specify q VO1 VO2 VO8 VO3 VO6 VO7 V99 24 V coils are not available on Sizes 4-7. On Sizes 00-3, where 24 V coils are available, Form S (separate control) must be specified. Factory Modifications (FORMS)............... Refer to Catalog 9999CT9701 Application Data.................................................................... Pages 13-16 Dimensions............................................................................ Pages 17-20 Separate Enclosures (Class 9991)........... Refer to Catalog 9999CT9701 Replacement Parts (Class 9998).............. Refer to Catalog 9999CT9701 Type S Accessories (Class 9999) ............ Refer to Catalog 9999CT9701 How to Order: To Order Specify: • Class Number • Type Number • Coil Voltage Code • Form(s) Catalog Number Class Type Coil Voltage Code Form(s) 8536 SBA2 VO2 H3O 9 5/98 © 1998 Square D All Rights Reserved Full Voltage Starters — NEMA Selection – Class 8536 2-Pole Single Phase — 600 Volts AC Maximum — 50-60 Hertz Thermal Units — One Thermal Unit Required Continuous Motor NEMA Current Volts Size Ratings 00 9 0 18 1 27 1P 36 2 45 Max. HP 1⁄3 115 230 115 230 115 230 115 230 115 230 Open t Type Coil Voltage 120 240 120 240 120 240 120 240 120 240 1 1 2 2 3 3 5 3 71⁄2 NEMA Type 1 General Purpose Enclosure Type Type SAO11V02 SAO11V03 SBO1V02 SBO1V03 SCO1V02 SCO1V03 SCO2V02 SCO2V03 SDO6V02 SDO6V03 SAG11V02 SAG11V03 SBG1V02 SBG1V03 SCG1V02 SCG1V03 SCG2V02 SCG2V03 SDG6V02 SDG6V03 NEMA Type 4X NEMA Type 4 & 4X Watertight, Dusttight, Watertight, Dusttight Corrosion-Resistant Brushed Stainless Glass-Polyester Steel Enclosure Enclosure Type Type Use Size 0 Use Size 0 SBW11V02 SBW11V03 SCW11V02 SCW11V03 SCW12V02 SCW12V03 SDW16V02 SDW16V03 SBW21V02 SBW21V03 SCW21V02 SCW21V03 SCW22V02 SCW22V03 SDW26V02 SDW26V03 4-Pole, 2-Phase — 600 Volts AC Maximum — 50-60 Hertz — Two Thermal Units Required Continuous Motor NEMA Current Volts Size Ratings Max. HP Open t Type Coil Voltage Type 0 1 2 3 4 j t NEMA Type 1 General Purpose Enclosure Type NEMA Type 4X NEMA Type 4 & 4X Watertight, Dusttight, Watertight, Dusttight Corrosion-Resistant Brushed Stainless Glass-Polyester Steel Enclosure Enclosure Type Type Separate Controlj 120 SBO3V02S SBG3V02S SBW13V02S SBW23V02S 200 3 208 SBO3V08 SBG3V08 SBW13V08 SBW23V08 230 3 240 SBO3V03 SBG3V03 SBW13V03 SBW23V03 18 460 10 480 SBO3V06 SBG3V06 SBW13V06 SBW23V06 575 10 600 SBO3V07 SBG3V07 SBW13V07 SBW23V07 Separate Controlj 120 SCO4V02S SCG4V02S SCW14V02S SCW24V02S 200 71⁄2 208 SCO4V08 SCG4V08 SCW14V08 SCW24V08 27 230 71⁄2 240 SCO4V03 SCG4V03 SCW14V03 SCW24V03 460 10 480 SCO4V06 SCG4V06 SCW14V06 SCW24V06 575 10 600 SCO4V07 SCG4V07 SCW14V07 SCW24V07 Separate Controlj 120 SDO2V02S SDG2V02S SDW12V02S SDW22V02S 200 10 208 SDO2V08 SDG2V08 SDW12V08 SDW22V08 230 15 240 SDO2V03 SDG2V03 SDW12V03 SDW22V03 45 460 25 480 SDO2V06 SDG2V06 SDW12V06 SDW22V06 575 25 600 SDO2V07 SDG2V07 SDW12V07 SDW22V07 Separate Controlj 120 SEO2V02S SEG2V02S SEW12V02S 200 15 208 SEO2V08 SEG2V08 SEW12V08 90 230 30 240 SEO2V03 SEG2V03 SEW12V03 460 50 480 SEO2V06 SEG2V06 SEW12V06 575 50 600 SEO2V07 SEG2V07 SEW12V07 Consult Local Square D Field Office Separate Controlj 120 SFO2V02S SFG2V02S SFW12V02S 200 40 208 SFO2V08 SFG2V08 SFW12V08 135 230 50 240 SFO2V03 SFG2V03 SFW12V03 460 100 480 SFO2V06 SFG2V06 SFW12V06 575 100 600 SFO2V07 SFG2V07 SFW12V07 120 Volt Polyphase starters are wired for separate control. Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed in selection table above or additional standard voltage codes below and insert as shown in the HOW TO ORDER block. Coil Voltage Codes Voltage Code 60 Hz 50 Hz 24q 120 208 240 480 600 Specify ... 110 ... 220 440 550 Specify q File E78351 CCN NLDX VO1 VO2 VO8 VO3 VO6 VO7 V99 24 V coils are not available on Sizes 4-7. On Sizes 00-3, where 24 V coils are available, Form S (separate control) must be specified. How to Order: To Order Specify: File LR60905 Class 3211-04 IEC 947-4-1 • Class Number • Type Number • Coil Voltage Code • Form(s) Catalog Number Class Type Coil Voltage Code Form(s) 8536 SCG1 VO2 P1 Factory Modifications (FORMS) ...............Refer to Catalog 9999CT9701 Application Data ................................................................... Pages 13-16 Dimensions ........................................................................... Pages 17-20 Separate Enclosures (Class 9991) ...........Refer to Catalog 9999CT9701 Replacement Parts (Class 9998) ..............Refer to Catalog 9999CT9701 Type S Accessories (Class 9999) .............Refer to Catalog 9999CT9701 10 © 1998 Square D All Rights Reserved 5/98 Full Voltage Starters — NEMA Selection – Class 8536 2-Pole Single Phase — 600 Volts AC Maximum — 50-60 Hertz — One Thermal Unit Required Devices require 1 thermal unit Continuous Current Ratings NEMA Size 00 115 230 115 230 115 230 115 230 115 230 9 0 18 1 27 1P 36 2 45 Motor Volts Max. HP 1⁄3 t Coil Voltage 120 240 120 240 120 240 120 240 120 240 1 1 2 2 3 3 5 3 71⁄2 NEMA Type 7 & 9 Hazardous Locations Class I, Groups C & D Class II, Groups E, F, & G Bolted Type Cast Cast Ironc Aluminum USE Size 0 SBT1V02 SBT1V03 SCT1V02 SCT1V03 SCT2V02 SCT2V03 SDT6V02 SDT6V03 SBT1V02 SBT1V03 SCT1V02 SCT1V03 SCT2V02 SCT2V03 SDT6V02 SDT6V03 NEMA Type 12/3Rf NEMA Type 9 Dusttight & Driptight Hazardous Locations Industrial Use Class II, Groups E, F, & G Enclosure SPIN TOP® Type Type USE Size 0 USE Size 0 Use Size 0 SBR1V02 SBR1V03 SCR1V02 SCR1V03 SCR2V02 SCR2V03 SDR6V02 SDR6V03 SBE1V02 SBE1V03 SCE1V02 SCE1V03 SCE2V02 SCE2V03 SDE6V02 SDE6V03 SBA1V02 SBA1V03 SCA1V02 SCA1V03 SCA2V02 SCA2V03 SDA6V02 SDA6V03 Type 4-Pole 2-Phase — 600 Volts AC Maximum — 50-60 Hertz —Two Thermal Units Required Continuous Current Ratings NEMA Size 0 1 2 3 4 j f c t Motor Volts Max. HP t Coil Voltage NEMA Type 7 & 9 Hazardous Locations Class I, Groups C & D Class II, Groups E, F, & G Bolted Type Cast Cast Ironc Aluminum NEMA Type 12 NEMA Type 9 Dusttight & Driptight Hazardous Locations Industrial Use Class II, Groups E, F, & G Enclosure SPIN TOP® Type Type Type Separate Controlj 120 SBT3V02S SBR3V02S SBA3V02S Consult Local 200 3 208 SBT3V08 SBR3V08 SBA3V08 Square D ... 230 3 240 SBT3V03 SBR3V03 SBA3V03 460 5 480 SBT3V06 SBR3V06 SBA3V06 Field Office 575 5 600 SBT3V07 SBR3V07 SBA3V07 Separate Controlj 120 SCT4V02S SCR4V02S SCA4V02S Consult Local 208 SCT4V08 SCR4V08 SCA4V08 200 71⁄2 240 SCT4V03 SCR4V03 SCA4V03 230 71⁄2 27 Square D ... 460 10 480 SCT4V06 SCR4V06 SCA4V06 Field Office 575 10 600 SCT4V07 SCR4V07 SCA4V07 Separate Controlj 120 SDT2V02S SDR2V02S SDA2V02S Consult Local 200 10 208 SDT2V08 SDR2V08 SDA2V08 45 Square D ... 230 15 240 SDT2V03 SDR2V03 SDA2V03 460 25 480 SDT2V06 SDR2V06 SDA2V06 Field Office 575 25 600 SDT2V07 SDR2V07 SDA2V07 Separate Controlj 120 SER2V02S SEA2V02S Consult Local Consult Local 200 25 208 SER2V08 SEA2V08 90 Square D Square D ... 230 30 240 SER2V03 SEA2V03 460 50 480 SER2V06 SEA2V06 Field Office Field Office 575 50 600 SER2V07 SEA2V07 Separate Controlj 120 SFA2V02S Consult Local Consult Local 200 40 208 SFA2V08 135 Square D Square D ... ... 230 50 240 SFA2V03 460 100 480 SFA2V06 Field Office Field Office 575 100 600 SFA2V07 120 Volt Polyphase contactors are wired for separate control. For NEMA Type 3R enclosed devices (2-Pole only), change ‘A’ in Type designation to ‘H’, no additional charge. Limited to one Pilot Light and Selector Switch or Start-Stop Push Button. Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed in selection table above or additional standard voltage codes below and insert as shown in the HOW TO ORDER block. 18 Coil Voltage Codes Voltage Code 60 Hz 50 Hz 24q 120 208 240 480 600 Specify ... 110 ... 220 440 550 Specify q VO1 VO2 VO8 VO3 VO6 VO7 V99 24 V coils are not available on Sizes 4-7. On Sizes 00-3, where 24 V coils are available, Form S (separate control) must be specified. How to Order: To Order Specify: Factory Modifications (FORMS)............... Refer to Catalog 9999CT9701 Application Data.................................................................... Pages 13-16 Dimensions............................................................................ Pages 17-20 Separate Enclosures (Class 9991)........... Refer to Catalog 9999CT9701 Replacement Parts (Class 9998).............. Refer to Catalog 9999CT9701 Type S Accessories (Class 9999) ............ Refer to Catalog 9999CT9701 • Class Number • Type Number • Coil Voltage Code • Form(s) Catalog Number Class Type Coil Voltage Code Form(s) 8536 SCA1 VO3 P1 11 5/98 © 1998 Square D All Rights Reserved Full Voltage Starters Selection – Class 8536 Types SB-SD with Auxiliary Load Terminals – Class 8536 3-Pole Polyphase — Three Thermal Units Required It is sometimes desirable to use the capacitors in motor branch circuits to improve power factor. The Size 0-2 Type SB-SD starters listed included three auxiliary terminals to allow easy connection of power factor correction capacitors. When capacitors are connected using these terminals, no adjustment on the selection of thermal units is necessary. These terminals are also available as a kit Class 9999 Type PFL for Type S NEMA Size 0, 1 and 2 Starters with Motor Logic overload relays. These terminals are available for connection of power factor (PF) correction capacitors. These kits are sold separately and are not factory installed. NEMA Size Motor Volts Maximum HP Coil Voltage Open Type 0 Separate Controlj 200 230 460 575 3 3 5 5 120 208 240 480 600 SBTO2V02S SBTO2V08 SBTO2V03 SBTO2V06 SBTO2V07 1 Separate Controlj 200 230 460 575 71⁄2 71⁄2 10 10 120 208 240 480 600 SBTO3V02S SBTO3V08 SBTO3V03 SBTO3V06 SBTO3V07 2 Separate Controlj 200 230 460 575 10 15 25 25 120 208 240 480 600 SDTO1V02S SDTO1V08 SDTO1V03 SDTO1V06 SDTO1V07 120 Volt polyphase starters are wired for separate control. j Extra Capacity Single Phase Starters 2-Pole Single Phase — 250 Volts AC Maximum — 50-60 Hertz Thermal Units — Devices require 1 thermal unit. Standard trip. t Open Type NEMA Type 1 General Purpose Enclosure NEMA Type 3R Rainproof, Sleet Resistant, Outdoor Use Enclosure NEMA Type 4 & 4X Watertight, Dusttight Brushed Stainless Steel Enclosure (Sizes 0-5) NEMA Type 4X Watertight Corrosion Resistant Class-Polyester Enclosure NEMA Type 12 Dusttight & Driptight Industrial Use Enclosure Motor Volts Max. HP Type Type Type Type Type 115 230 5 10 120 240 SDO8V02 SDO8V03 ... SDH8V02 SDH8V03 ... ... ... 115 230 71⁄2 120 240 SEO6V02 SEO6V03 SEG6V02 SEG6V03 SEH6V02 SEH6V03 SEW16V02 SEW16V03 SEW26V02 SEW26V03 SEA6V02 SEA6V03 15 Coil Voltage Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed in selection tables above or additional standard voltage codes below and insert as shown in the HOW TO ORDER bolck. t Coil Voltage Codes Voltage Code 60 Hz 50 Hz 24 120 208 240 480 600 Specify ... 110 ... 220 440 550 Specify VO1 VO2 VO8 VO3 VO6 VO7 V99 How to Order: To Order Specify: • Class Number • Type Number • Coil Voltage Code • Form(s) Catalog Number Class Type Coil Voltage Code Form(s) 8536 SEG6 VO3 P1 Factory Modifications (FORMS) ...............Refer to Catalog 9999CT9701 Application Data ................................................................... Pages 13-16 Dimensions ........................................................................... Pages 17-20 Separate Enclosures (Class 9991) ...........Refer to Catalog 9999CT9701 Replacement Parts (Class 9998) ..............Refer to Catalog 9999CT9701 Type S Accessories (Class 9999) .............Refer to Catalog 9999CT9701 12 © 1998 Square D All Rights Reserved 5/98 Full Voltage Contactors and Starters — NEMA Application Data – Class 8502, 8536 NEMA Load Size Volts Maximum Horsepower Rating – Nonplugging and Nonjogging Duty Single PolyPhase Phase KVA Rating for Switching Transformer Primaries at 50 or 60 Cycles Tungsten Resistance Maximum Transformers Transformers and Heating Loads, Continuous Service – Horsepower Having Inrush Having Inrush Infrared KW – Other Current Limit Rating – Currents (Worst Currents (Worst Lamp Than Infrared Rating, Current Plugging and Case Peak) of Case Peak) of Load, Lamp Loads Amperes – Rating, Jogging Duty j Not More Than Over 20 Through Amperes – u 600 Volt Amperes 20 Times Peak of 40 Times Peak of 250 Volts Max. t Continuous Continuous Max. Current Rating Current Rating a Single PolySingle PolySingle PolySingle PolyPhase Phase Phase Phase Phase Phase Phase Phase 3 Phase Rating for Switching Capacitors k KVAR 1⁄2 115 ... ... ... 9 11 5 ... ... ... ... ... ... ... 200 ... 11⁄2 ... ... 9 11 5 ... ... ... ... ... ... ... 1⁄2 230 1 1 . . . . . . 9 11 5 . . . . . . . . . . . . . . . . . . . .. 00 380 ... 11⁄2 ... ... 9 11 ... ... ... ... ... ... ... ... 460 ... 2 ... ... 9 11 ... ... ... ... ... ... ... ... 575 ... 2 ... ... 9 11 ... ... ... ... ... ... ... ... 1⁄2 ... 18 21 10 ... ... 0.6 ... 0.3 ... ... 115 1 ... 1 18 21 10 ... ... ... 1.8 ... 0.9 ... 200 ... 3 ... 1 ⁄2 18 21 10 ... ... 1.2 2.1 0.6 1.0 ... 230 2 3 1 11⁄2 0 18 21 ... ... ... ... ... ... ... ... 380 ... 5 ... 11⁄2 460 ... 5 ... 2 18 21 ... ... ... 2.4 4.2 1.2 2.1 ... 575 ... 5 ... 2 18 21 ... ... ... 3.0 5.2 1.5 2.6 ... 115 2 ... 1 ... 27 32 15 3 5 1.2 ... 0.6 ... ... 200 ... 71⁄2 ... 3 27 32 15 ... 9.1 ... 3.6 ... 1.8 ... 2 3 27 32 15 6 10 2.4 4.3 1.2 2.1 ... 230 3 71⁄2 1 380 ... 10 ... 5 27 32 ... ... 16.5 ... ... ... ... ... 460 ... 10 ... 5 27 32 ... 12 20 4.9 8.5 2.5 4.3 ... 575 ... 10 ... 5 27 32 ... 15 25 6.2 11.0 3.1 5.3 ... ... 36 42 24 ... ... ... ... ... ... ... 115 3 ... 11⁄2 1P 230 5 ... 3 ... 36 42 24 ... ... ... ... ... ... ... 115 3 ... 2 ... 45 52 30 5 8.5 2.1 ... 1.0 ... ... 45 52 30 ... 15.4 ... 6.3 ... 3.1 ... 200 ... 10 ... 71⁄2 15 5 10 45 52 30 10 17 4.1 7.2 2.1 3.6 8 230 71⁄2 2 380 ... 25 ... 15 45 52 ... ... 28 ... ... ... ... ... 460 ... 25 ... 15 45 52 ... 20 34 8.3 14 4.2 7.2 16 575 ... 25 ... 15 45 52 ... 25 43 10.0 18 5.2 8.9 20 115 ... ... ... ... 90 104 60 10 17 4.1 ... 2.0 ... ... 200 ... 25 ... 15 90 104 60 ... 31 ... 12 ... 6.1 ... 230 ... 30 ... 20 90 104 60 20 34 8.1 14 4.1 7.0 27 3 380 ... 50 ... 30 90 104 ... ... 56 ... ... ... ... ... 460 ... 50 ... 30 90 104 ... 40 68 16 28 8.1 14 53 575 ... 50 ... 30 90 104 ... 50 86 20 35 10 18 67 200 ... 40 ... 25 135 156 120 ... 45 ... 20 ... 10 ... 230 ... 50 ... 30 135 156 120 30 52 14 23 6.8 12 40 4 380 ... 75 ... 50 135 156 ... ... 86.7 ... ... ... ... ... 460 ... 100 ... 60 135 156 ... 60 105 27 47 14 23 80 575 ... 100 ... 60 135 156 ... 75 130 34 59 17 29 100 200 ... 75 ... 60 270 311 240 ... 91 ... 41 ... 20 ... 230 ... 100 ... 75 270 311 240 60 105 27 47 14 24 80 5 380 ... 150 ... 125 270 311 ... ... 173 ... ... ... ... ... 460 ... 200 ... 150 270 311 ... 120 210 54 94 27 47 160 575 ... 200 ... 150 270 311 ... 150 260 68 117 34 59 200 200 ... 150 ... 125 540 621 480 ... 182 ... 81 ... 41 ... 230 ... 200 ... 150 540 621 480 120 210 54 94 27 47 160 6f 380 ... 300 ... 250 540 621 ... ... 342 ... ... ... ... ... 460 ... 400 ... 300 540 621 ... 240 415 108 188 54 94 320 575 ... 400 ... 300 540 621 ... 300 515 135 234 68 117 400 230 ... 300 ... ... 810 932 ... 180 315 ... ... ... ... 240 7f 460 ... 600 ... ... 810 932 ... 360 625 ... ... ... ... 480 575 ... 600 ... ... 810 932 ... 450 775 ... ... ... ... 600 Tables and footnotes are taken from NEMA Standards. j Ratings shown are for applications requiring repeated interruptions of stalled motor current or repeated closing of high transient currents encountered in rapid motor reversal, involving more than five openings or closings per minute and more than ten in a ten-minute period, such as plug-stop, plug-reverse or jogging duty. Ratings apply to single speed and multi-speed controllers. t Per NEMA Standards paragraph ICS 2-321.20, the service-limit current represents the maximum ms current, in amperes, which the controller may be expected to carry for protracted periods in normal service. At service-limit current ratings, temperature rises may exceed those obtained by testing the controller at its continuous current rating. The ultimate trip current of overcurrent (overload) relays or other motor protective devices shall not exceed the service-limit current ratings of the controller. a FLUORESCENT LAMP LOADS – 300 VOLTS AND LESS – The characteristics of fluorescent lamps are such that it is not necessary to derate Class 8502 contactors below their normal continuous current rating. Class 8903 contactors may also be used with fluorescent lamp loads. For controlling tungsten and infrared lamp loads, and resistance heating loads, Class 8903 ac lighting contactors are recommended. These contactors are specifically designed for such loads and are applied at their full rating as listed in the Class 8903 Section. u Ratings apply to contactors which are employed to switch the load at the utilization voltage of the heat producing element with a duty which requires continuous operation of not more than five openings per minute. Class 8903 Types L and S lighting contactors are rated for resistance heating loads. k When discharged, a capacitor has essentially zero impedance. For repetitive switching by contactor, sufficient impedance should be connected in series to limit inrush current to not more than 6 times the contactor rated continuous current. In many installations, the impedance of connecting conductors may be sufficient for this purpose. When switching to connect additional banks, the banks already on the line may be charged and can supply additional available short-circuit current which should be considered when selecting the impedance to limit the current. The ratings for capacitor switching above assume the following maximum available fault currents: NEMA Size 2-3: 5,000 A RMS Sym.; NEMA Size 4-5: 10,000 A RMS Sym.; NEMA Size 6-7: 18,000 A RMS Sym. If available fault current is greater than these values, connect sufficient impedance in series as noted in the previous paragraph. f See Page 16 regarding operation rates for Size 6 & 7. The motor ratings in the above table are NEMA standard ratings and apply only when the code letter of the motor is the same as or occurs earlier in the alphabet than is shown in the table below. Motors having code letters occurring later in the alphabet may require a larger controller. Consult local Square D field office. Motor HP Rating Maximum Allowable Motor Code Letter 11⁄2-2 L 3-5 K 71⁄2 & above H 13 5/98 © 1998 Square D All Rights Reserved Full Voltage Contactors and Starters — NEMA Application Data – Class 8502, 8536 CLASS 8502 AND 8536 APPLICATION DATA Power Contact Ratings All contactors and starters are rated in accordance with NEMA standards. The ratings shown in the price tables are for normal service. For complete data on power contact ratings, refer to Page 13. Maintenance of Equipment Class 9998 Repair Parts Kits are available for all Class 8502 contactors and Class 8536 starters. Service bulletins with a complete list of replaceable parts are supplied with all enclosed devices. Separate bulletins can be ordered and are listed along with the appropriate contact parts kit. Device Service No. of NEMA Bulletin Type Series Poles Type Short Circuit Protection 00 According to the National Electrical Code branch circuit overcurrent protection must be provided for each contactor or starter. For starters refer to instructions furnished with the thermal unit selection table. For contactors (Class 8502 or 8702) provide branch circuit overcurrent protection in accordance with the National Electrical Code, except do not exceed the maximum protective device ratings in table below. Class NEMA Maximum K5, RK5 or Size Voltage RK1 Fuse (Ampere) 00 0 1 2 3 4 5 6 7 t 600 250 600 250 600 250 600 250 600 250 600 600 600 600 Class L Fuse only. 10 12 20 25 30 40 60 100 125 200 400 600 600 Class J or T Fuse (Ampere) Inverse-Time Circuit Breaker (Ampere) 15 15 30 60 100 200 400 600 1200t 1600t 20 35 40 60 80 90 125 150 225 400 800 1200 SA Replacement Contacts Class 9998 Type A 2-3 362AS SL2 B 2-3 556AS SJ1 0 SB A&B 1-3 4 5 SL2 277AS SL12 277AS & 250AS (1)SL12 & (1)SL22 277AS & 250AS or (1)SL2 & (2)SL22 1 SC A&B 1-3 4 5 SL3 278AS SL13 278AS & 250AS (1)SL13 & (1)SL22 278AS & 250AS or (1)SL3 & (2)SL22 1P SC A 2 278AS SL3 2 SD A 2-3 4 5 SL4 279AS SL14 279AS & 293AS (1)SL14 & (1)SL24 279AS & 293AS or (1)SL4 & (2)SL24 3 SE A 2 3 4 5 305AS 305AS 326AS 326AS SL6 SL7 (2)SL6 (1)SL6 & (1)SL7 4 SF A 2 3 4 5 306AS 306AS 326AS 326AS SL8 SL9 (2)SL8 (1)SL8 & (1)SL9 5 SG A 2 3 328AS 328AS SL10 SL11 A 6 SH 2 3 342AS 342AS SL25 SL26 B 2 3 370AS 370AS SL25 SL26 A 2 3 397AS SL30 SL31 7 SJ Terminals Capacitor Switching Power Terminals The kilovar ratings of enclosed, three phase contactors used as switches for capacitor loads, when only one load appears on the secondary of a distribution system are shown in the table on Page 13. NEMA Type Size Type of Lug Wire Sizest Min.-Max. Wire Type Sizest of Lug Min.-Max. 00, 0&1 SA, SB & SC Pressure Wire #14-#8 Pressure #16-#12 Wire 2 SD Box Lug #14-#4 Pressure #16-#12 Wire 3 SE Box Lug #14-1/0 Pressure #16-#12 Wire 4 SF Box Lug #8-250 kcmil Pressure #16-#12 Wire 5 SG Box Lug #4-500 kcmil Pressure #16-#12 Wire 6 SH Parallel Groove One or two 250-500 kcmil per phase Pressure #16-#12 Wire 7 SJ Parallel Groove One to four 250-500 kcmil per phase Pressure #16-#12 Wire Coil Burdenq Inrush VA Sealed VA Sealed Watts NEMA No. of 50 60 50 60 50 60 Size Poles Hertz Hertz Hertz Hertz Hertz Hertz 00 0&1 2-3 ... 165 ... 33 ... 6 1-5 232 245 26 27 7.7 7.8 2&3 296 311 36 37 2 12 14 4&5 429 438 37 38 2-3 676 700 47 46 15 14 3 4-5 1260 1185 89 85 23.4 22 4 2-5 ... 973 ... 81 ... 25 5 2-3 2970 2970 250 212 42 39 6a 2-3 1495 1780 56 48 27 32 7a 2-3 ... 1960 ... 59 ... 36 q Mean values. a Size 6 and 7 have a DC coil. The values shown are for the AC input to the DC power supply that provides power to the coil. Control Terminals t Solid or stranded copper wire. 14 © 1998 Square D All Rights Reserved 5/98 Full Voltage Contactors and Starters — NEMA Application Data – Class 8502, 8536 Control Circuit Transformers Auxiliary Units Auxiliary contacts, power poles, and timer attachments can be added by the factory or in the field on all Type S starters and contactors. The table below shows the maximum number of auxiliary units (in addition to the holding circuit contact) that can be added to a given size starter or contactor. In addition, it is possible to add a second internal contact on NEMA Size 0, 1, and 2 contactors and starters. No. of Maximum Number of External Poles of NEMA Auxiliary Units (In addition to Type Basic Size holding circuit contact) Contactor 00 SA SB 0, 1 & 2 SC SD SE 3, 4 & 5 SF SG 6&7 SH SJ 4 single circuit auxiliary contacts (N.O. or N.C.) if second internal auxiliary contact is not used. 4 single circuit auxiliary contacts (N.O. or N.C.) 3 single circuit auxiliary contacts (N.O. or N.C.) plus 1 attached timer (ON or OFF delay). 2 single circuit auxiliary contacts (N.O. or N.C.) 1, 2 or 3 plus 1 power pole adder (1 or 2 poles, N.O. or N.C.). 1 attached timer (ON or OFF delay) plus 1 power pole adder (1 or 2 poles, N.O. or N.C.) plus 1 auxiliary contact. 2 single circuit auxiliary contacts (N.O. or N.C.) 4 or 5 1 timer attachment plus 1 auxiliary contact. 4 single circuit auxiliary contacts (N.O. or N.C.) 2-5 2 single circuit (Sizes 3 & 4) or 3 single circuit (Size 3 & 4) (Size 5) auxiliary contacts plus 1 attached timer (ON or OFF delay). 2 single circuit auxiliary contacts (N.O. or N.C.) 2-3 plus 1 NEMA Size 0-1 or Size 2 power pole (Size 5) adder (1 or 2 poles, N.O. or N.C.) 4 single circuit auxiliary contacts (N.O. or N.C.) 3 single circuit auxiliary contacts (N.O. or N.C.) plus 1 attached timer (ON or OFF delay). 2-3 2 single circuit auxiliary contacts (N.O. or N.C.) plus 1 NEMA Size 0-1 or Size 2 power pole adder (1 or 2 poles, N.O. or N.C.) Class 9070 Type T machine tool control transformers are normally used when it is necessary to provide a lower voltage to the control circuit. This transformer with fused protection may be ordered from the factory by specifying Form F4T. The addition of a transformer often requires the use of a larger enclosure. The table below shows the transformer selection for given sized starters and contactors with or without auxiliary units. NEMA Size 2-3 See Class 9999 for field modification kits. Form Number of Additional Auxiliary Contacts When ordering factory installed auxiliary contacts, the Form designations listed should be used. Number of N.O. Contacts 0 1 2 3 3 4 Number of N.C. Contacts Form Number 1 2 3 4 0 1 2 3 0 1 2 0 1 0 X01 X02 X03 X04 X10 X11 X12 X13 X20 X21 X22 X30 X31 X40 Transformer Class 9070 Type With max. of 2 auxiliary contacts SB SC 0&1 1-3 With timer and maximum of 1 auxiliary contact T50 With 3 or 4 auxiliary contacts with timer and 2 or T100 3 auxiliary contacts SB SC 4&5 With or without auxiliary contacts or timer 0&1 Mechanically SB Interlocked SC Devices 1-5 With or without attachments T100 2 SD 2-5 With or without attachments T100 3 SE 2-3 With or without attachments GO3j 3 SE 4&5 With or without attachments T300 4 SF 2-5 With or without attachments T300 5 SG 2-3 Any T500 6, 7 SH, SJ 2-3 Any u 0&1 j Factory Installed Auxiliary Contacts Additional auxiliary contacts may be factory or field added to any Type S contactor or starter. See table above for maximum number of auxiliary units. The table below lists the Form designations for factory installed electrical contacts. No. Type of Auxiliary Units Poles u T100 Class 8502 & 8536 Type S, Size 3 standard NEMA Type 1, 4 and 12 enclosures have space for field mounting a fused control circuit transformer. A Class 9070 Type GFT3 transformer and fuse block kit is available for Form F4T requirements in a NEMA Type 1 enclosure. NEMA Type 4 and 12 enclosures utilize a Class 9070 T150 transformer and a Class 9999 SF4 fuse block. A Class 9070 transformer is an integral part of the Size 6 and Size 7 control circuit providing 120 volt control circuit voltage as standard. Power Poles Single or double circuit power pole adders may be factory or field installed on 2 and 3 pole Type S contactors and starters. The table below lists the Form designation for factory installed power pole adders. Only one power pole adder may be installed per contactor. Type NEMA Size Class 9999 Type Form Designation 1 N.O. 0, 1 2 SB6 SB11 Y428 Y436 1 N.C. 0, 1 2 SB7 SB12 Y429 Y437 1 N.O., 1 N.C. 0, 1 2 SB8 SB13 Y435 Y440 2 N.O. 0, 1 2 SB9 SB14 Y430 Y438 2 N.C. 0, 1 2 SB10 SB15 Y434 Y439 15 5/98 © 1998 Square D All Rights Reserved Full Voltage Contactors and Starters — NEMA Application Data – Class 8502, 8536 Size 6 Type SH and Size 7 Type SJ Contactors and Starters Size 6 Type SH and Size 7 Type SJ contactors and starters have a DC coil operated by a solid state rectifier circuit mounted on the device and powered from an ac source. The Size 6 and 7 are equipped as standard with a fused control circuit transformer (Form F4T) rated 240/480-120 volts 60 hertz, 220/440-110 volts 50 hertz. The purpose of this transformer is to provide an isolated 120 volts 60 hertz, 110 volts 50 hertz, supply for the control circuit. Size 6 and 7 devices may be ordered for other system voltages by specifying the voltage and frequency desired. Size 6 Starter 8536 SH Operation Rates Continuous operation rate: 3 operations/minute maximum. Jogging or Plugging Duty: 15 operations/minute – 3 minutes maximum. 4. Standard controllers are wired for common control and are not convertible for operation of the control circuit from a separate source of supply voltage. Controllers designated Form S have special wiring designed for separate control. They are furnished with an isolating transformer, usually having a 120 volt primary and 120 volt secondary, that must not be bypassed. Form S controllers are not convertible for operation on common control. The tables below give the replacement transformers for Type S Sizes 6 and 7 contactors and starters. To change voltages on these devices, coils are not changed, instead transformers with the desired voltage are changed. Replacement Control Transformers for Type S Size 6 Voltage Class 9070 Type Field conversion for other system voltages is accomplished by one of the following methods, NOT BY THE USUAL PRACTICE OF CHANGING THE COIL: Size 7 Starter 8536 SJ 1. If the factory wiring is indicated as being for 480 volts 60 hertz, 440 volts 50 hertz, conversion to 240 volts 60 hertz, 220 volts 50 hertz, can be accomplished by reconnecting the control transformer as illustrated on instruction sheet supplied with the controller. This is the same method that would be used on Class 9070 control circuit transformers. Conversion to any other voltage requires replacement of the control transformer. For other system voltages: i.e. 208, 277, 380, 600 volts, a new transformer with single voltage primary must be selected from table at right. Control transformer connections are illustrated on the instruction sheet supplied with the controller. 2. If the factory wiring is indicated as being for any voltage other than 480 volts 60 hertz, 440 volts 50 hertz, conversion to any other voltage requires replacement of the control transformer. Refer to table at right. 3. The standard transformer supplied may be used to power a maximum of five Class 9001 Type K illuminated operators powered with transformer type light modules. When extra capacity to power control relays or other inductive loads is required, a second transformer must be added. Extra capacity can be purchased as Form F4T with additions in 100 VA increments. 60 Hertz 50 Hertz 240/480-120 208-120 277-120 ... 600-120 120-120 240-120 220/440-110 ... ... 380-110 550-110 110-110 220-110 EO3S2A EO3S2B EO3S2C EO3S2D EO3S2E EO3S2F EO3S2G Replacement Control Transformers for Type S Size 7 Voltage Class 9070 Type 60 Hertz 50 Hertz 240/480-120 208-120 277-120 ... 600-120 120-120 240-120 220/440-110 ... ... 380-110 550-110 110-110 220-110 EO19S2A EO19S2B EO19S2C EO19S2D EO19S2E EO19S2F EO19S2G Auxiliary Contacts A N.O. holding circuit contact and a N.C. auxiliary contact are provided as standard. The holding circuit contact may or may not be required for either 3-wire or 2-wire control. Size 6 and 7 devices have an additional N.C. auxiliary contact which is wired in the coil control circuit. DO NOT USE THIS N.C. CONTACT FOR ANY OTHER PURPOSE. 16 © 1998 Square D All Rights Reserved 5/98 Full Voltage Contactors and Starters — NEMA Approximate Dimensions, Shipping Weights – Class 8502, 8536 Class 8502 Open Type Class 8536 Open Type A A D E G F C F C G B H B H RESET I Figure 1 I D E Figure 2 Class 8502 NEMA Size Type Dimensions – Inches/mm (Refer to Appropriate Figure) No. Fig. Mtg. A B C D E F of No. Screws Poles IN mm IN mm IN mm IN mm IN mm IN 00 SAO 2-3 0 1 SBO SCO 1-3 4-5 2 SDO 3 G H Wt (Lbs) I mm IN mm IN mm IN mm (2) #10 3.22 82 4.34 110 4.22 107 1.63 41 1.63 41 .22 6 3.94 100 ... ... ... ... 4 1 (2) #10 3.22 4.25 82 108 4.34 4.34 110 110 4.22 4.22 107 107 1.63 41 1.63 41 1.63 41 2.63 67 .22 .22 6 6 3.94 3.94 100 100 ... ... ... ... ... ... ... ... 4 41⁄2 2-3 4-5 1 (3) #10 4.94 5.63 125 143 5.13 5.13 130 130 4.94 4.94 125 125 2.16 55 2.16 55 2.16 55 3.47 88 .22 .22 6 6 4.59 4.59 117 117 .53 .53 13 13 1.06 27 1.06 27 63⁄4 81⁄4 SEO 2-3 4-5 1 (3) 1⁄4" (3) 5⁄16" 5.47 9.75 139 248 7.09 7.88 180 200 6.50 6.50 165 165 1.88 48 3.59 91 .31 3.94 100 5.81 148 .31 8 8 6.03 7.00 153 178 3.25 4.53 83 115 4.75 121 14 9.06 230 22 4 SFO 2-3 4-5 1 (3) 5⁄16" (3) 5⁄16" 6.00 9.75 152 248 8.19 8.19 208 208 6.50 6.50 165 165 2.06 52 3.94 100 .31 3.94 100 5.81 148 .31 8 8 7.00 7.00 178 178 3.59 4.53 91 115 5.31 135 18 9.06 230 22 5 SGO 2-3 1 (3) 1⁄2" 8.66 220 12.31 313 8.75 222 3.25 83 5.81 148 .63 16 11.13 283 4.75 121 7.25 184 45 6 SHO 2-3 1 (3) 1⁄2" 12.34 313 28.06 713 9.00 229 3.53 90 5.78 147 5.06 129 18.56 471 4.75 121 7.25 184 80 7 SJO 2-3 1 (3) 1⁄2" 12.34 313 37.25 946 10.88 276 3.53 90 5.78 147 7.22 183 22.38 568 4.75 121 7.25 184 135 00, 0, 1, 1P SAO-SCO 2-3 2 (3) #10 3.50 89 6.77 172 4.22 107 .50 13 1.00 25 1.61 41 .20 5 6.25 159 3.97 101 5 0, 1 SBO-SCO 4 2 (3) #10 4.53 115 6.77 172 4.22 107 .50 13 1.00 25 2.66 68 .20 5 6.25 159 3.97 101 51⁄2 2 SDO 2-3 4 2 (3) #10 4.31 5.63 109 143 7.81 7.81 198 198 4.94 4.94 125 125 .50 .50 13 13 1.00 25 1.00 25 2.16 55 3.47 88 .20 .20 5 5 7.34 7.34 186 186 4.06 103 73⁄4 4.06 103 91⁄4 3 SEO 2-3 4 2 (3) 1⁄4" (3) 5⁄16" 5.47 9.75 139 248 11.09 282 12.13 308 6.50 6.50 165 165 .88 22 1.81 46 1.75 44 1.75 44 3.59 91 .31 5.81 148 .31 8 8 10.19 259 11.19 284 5.75 146 17 5.75 146 25 4 SFO 3 4 2 (3) 5⁄16" (3) 5⁄16" 6.00 9.75 152 248 12.88 327 12.88 327 6.50 6.50 165 165 1.81 46 1.81 46 1.75 44 1.75 44 3.94 100 .31 5.91 150 .31 8 8 11.19 284 11.19 284 5.75 146 22 5.75 146 25 5 SGO 3 2 (3) 1⁄2" 8.56 217 17.56 446 8.75 222 4.75 121 7.25 184 5.38 137 .63 16 16.38 416 6.00 152 62 6 SHO 3 2 (3) 1⁄2" 12.34 313 28.06 713 9.00 229 4.75 121 7.25 184 5.78 147 5.06 129 18.56 471 8.69 221 85 7 SJO 3 2 (3) 1⁄2" 12.34 313 37.25 946 10.88 276 4.75 121 7.25 184 5.78 147 7.22 183 22.38 568 9.00 229 140 8536 1 17 5/98 © 1998 Square D All Rights Reserved Full Voltage Contactors and Starters — NEMA Approximate Dimensions, Shipping Weights – Class 8502, 8536 NEMA Type 1 — General Purpose Enclosure B E H (3) Closing Plates A D K L C Pilot Light K (4) I Dia. Mounting Holes A J H E G A F B B G F RESET RESET H G H I H E Figure 3 D F C C Figure 4 Figure 5 NEMA Size Class Type No. of Poles Fig. Mtg. No. Screws Dimensions – Inches/mm (Refer to Appropriate Figure) C A B D E F G H 8502 8536 00 0 1 8502 & 8536 SAG SBG SCG All 3 (3) #10 6.00 152 10.00 254 5.28 134 5.56 141 3.00 76 .88 22 8.13 207 1.00 25 2 8502 & 8536 SDG All 3 (4) 1⁄4" 3 (4) 7⁄16" 12.69 322 21.81 554 25.16 639 44.22 1123 20.22 514 34.50 876 6.03 153 8.00 203 9.00 229 12.81 325 13.13 334 23.50 597 6.31 160 8.38 213 9.00 229 12.94 329 13.13 334 23.50 597 ... 3⁄8" 7.81 198 11.44 291 11.25 286 17.22 437 65.75 1670 93.00 2362 1.09 28 1.53 39 1.25 32 2.13 54 11.00 279 10.50 267 18.75 476 1.25 32 2.13 54 64.50 1638 1.09 28 1.53 39 22.31 567 40.00 1016 2.31 59 3 8502 & 8536 SEG All 4 8502 & 8536 SFG All 4 (4) 5 8502 & 8536 SGG All 4 (4) 9⁄16" 6 8502 & 8536 SHG All 5 (4) 11⁄16" 7 8502 & 8536 SJG All 5 ... ... 8.59 218 13.00 330 ... Wt (Lbs) Class Class 8502 8536 I J K L .94 24 4.13 105 5.00 127 ... ... 71⁄2 8 1.09 28 1.53 39 1.44 37 2.13 54 5.50 140 5.63 143 8.38 213 .44 11 .56 14 5.75 146 7.75 197 1.09 28 1.53 39 5.63 143 8.38 213 141⁄2 151⁄2 34 37 ... ... ... 52 56 ... ... ... 143 160 ... ... ... ... 226 231 ... ... Floor Mounting NEMA Type 1 — General Purpose Enclosure with Form F4T (4) H Dia. G Mounting Holes (4) I Dia. Mounting Holes A H F B B G RESET H E D A C E Figure 3 NEMA Class Size 0 1 F Dimensions – Inches/mm (Refer to Appropriate Figure) No. C Fig. Mtg. Type of A B D E No. Screws 8502 8536 Poles IN mm IN mm IN mm IN mm IN mm IN 8502 & 8536 SBG 8502 & 8536 SCG All All 6 6 (4) 9⁄32 (4) 9⁄32 6.34 161 15.88 403 5.00 127 5.19 132 2 8502 & 8536 SDG All 7 (4) 5⁄16 14.88 378 3 8502 & 8536 SEG 2–3 3 (4) 3⁄8 Same as Standard NEMA 1 Dimensions, see above. 4 8502 & 8536 SFG 2–3 7 (4) 3⁄8 18.16 461 5 6 7 D 8502 & 8536 SGG 8502 & 8536 SHG 8502 & 8536 SJG C Figure 3 All All All 7 5 5 9⁄16 (4) (4) 11⁄16 ... 14.13 359 29.16 741 7.56 9.25 192 235 7.66 9.25 195 235 4.66 F mm IN 21 G mm IN 118 .84 14.38 365 12.75 324 1.0 6 27 1.06 27 15.50 394 1.3 3 34 1.33 34 H I mm IN mm IN mm 19 7 ... ... 12.00 305 1.0 6 27 .3 1 8 26.50 673 1.3 3 34 .4 4 11 .75 .28 Same as Standard NEMA 1 Dimensions, see above. Form F4T is supplied as standard. Refer to Page 16. 18 © 1998 Square D All Rights Reserved 5/98 Full Voltage Contactors and Starters — NEMA Approximate Dimensions, Shipping Weights – Class 8502, 8536 A E D NEMA Type 4 & 4X — Stainless Steel Watertight Enclosuresq G D B I J K 8502 SBW SCW All 6.38 162 7.13 181 13.19 335 1.56 3.25 40 83 12.00 .59 305 15 1.19 30 11.78 299 1.63 41 ... SBW SCW All 6.38 162 7.81 198 13.19 335 1.56 3.25 40 83 12.00 .59 305 15 1.88 48 11.78 299 1.63 41 1" Dia. Hub 17 8536 2.31 .31 59 8 3⁄4" Dia. 2.31 .31 Hub 59 8 ... 18 8.13 207 7.88 200 16.19 411 1.56 5.00 40 127 15.00 1.09 1.94 381 28 49 14.75 375 2.00 51 ... 8.56 217 16.19 411 1.56 5.00 40 127 15.00 1.09 2.88 381 28 73 14.75 375 2.00 51 11⁄2" Dia. Hub 24 8.13 207 2.63 .31 67 8 3⁄4" Dia. 2.63 .31 Hub 67 8 ... 25 21⁄2" 65 ... Dia. Hub 69 ... ... 68 F C G (4) L Dia. Mounting Holes I 0 & 1 8502 2 W X All SEW H 8502 K Figure 8 NEMA Type 4 & 4X Watertight Enclosure A E SEW 8536 All SFW 18.16 8.75 461 222 18.16 9.56 461 243 32.22 818 32.22 818 3.08 12.00 30.50 .88 78 305 775 22 3.08 12.00 30.50 .88 78 305 775 22 3.69 94 4.50 114 26.72 679 26.72 679 2.56 65 2.56 65 W. Bot. L Only 3⁄4" 3.19 .44 Dia. 81 11 Hub 3⁄4" 21⁄2" Dia. Hub ... 73 3⁄4" 159 176 227 232 ... ... W Bot. Only X Top & Bot. 3.19 .44 Dia. 81 11 Hub 5 8502 & 8536 SGW All 17.22 12.63 47.22 437 321 1199 4.13 9.00 105 229 46.00 .63 1168 16 4.59 117 28.31 719 3.13 80 5.75 .56 Dia. 146 14 Hub 31⁄2" Dia. Hub 6q 8502 & 8536 SHW All 20.22 12.13 65.22 514 308 1657 4.13 12.00 64.00 .63 105 305 1626 16 4.59 117 30.81 783 2.69 68 3⁄4" 4.50 .56 Dia. 114 14 Hub (2) 3" Dia. Hub 7q 8502 & 8536 SJW All 34.50 23.50 101.00 Floor Mounting 876 597 2565 Size 6 and 7 are sheet steel enclosures and are rated NEMA Type 4 only. NEMA Type 4 & 4X — Stainless Steel Watertight Enclosures with Form F4Tq G D All SFW 3 & 4 q D SDW 8536 J Weight (Lbs) X Top & Bot. Class Class 8502 8536 Dimensions – Inches/mm (Figure 8) No. Type of B C D E F G H Poles A NEMA Class Size B NEMA Class Size F C G (4) L Dia. Mounting Holes 0 & 1 No. Type of Poles Dimensions – Inches/mm (Figure 9) SBW All All 8502 SCW SBW 8536 SCW I 8502 W X 2 J SDW A B C D E F 12.63 7.13 321 181 4.69 119 2.56 65 7.50 191 12.63 7.81 321 198 14.69 373 2.56 65 14.88 7.56 378 192 16.31 414 14.88 8.25 378 210 16.31 414 G H I J K L 13.50 .59 343 15 3.19 81 18.41 468 1.66 42 2.31 59 .31 8 3⁄4 1 7.50 191 13.50 .59 343 15 3.88 99 18.41 468 1.66 42 2.31 59 .31 8 3⁄4 1 2.56 65 9.75 248 15.00 .66 381 17 3.19 81 20.88 530 2.00 51 2.63 67 .31 8 3⁄4 11⁄2 2.56 65 9.75 248 15.00 .66 381 17 3.88 99 20.88 530 2.00 51 2.63 67 .31 8 3⁄4 11⁄2 All 8536 H SEW K Figure 9 NEMA Type 4 & 4X Watertight Enclosure 3 & 4 8502 2-3 Same as Standard NEMA Type 4 dimensions, see above. 2-3 See as Standard NEMA Type 4 dimensions, see above. SFW SEW 8536 SFW 5 8502 & 8536 SGW All 6q 8502 & 8536 SHW All 7q 8502 & 8536 SJW All Same as Standard NEMA Type 4 dimensions, see above. Form F4T is supplied as standard. Refer to Page 16. q Size 6 and 7 are sheet steel enclosures and are rated NEMA Type 4 only. 19 5/98 © 1998 Square D All Rights Reserved Full Voltage Contactors and Starters — NEMA Approximate Dimensions, Shipping Weights – Class 8502, 8536 A E D D B G Size 2 Only A E F C (2) L Dia. Mounting Holes (Size 1) Size 2 Only (4) L Dia. Mounting Holes (Size 2) C F RESET G 1.00 Conduit Hub Top and Bottom Size 1 Conduit Hub 38 Top and Bottom Size 2 .75 Conduit Hub in 19 Bottom Size 1 and Size 2 25 1.50 I B J H K Figure 10A Figure 10B NEMA Type 4X — Watertight and Corrosion Resistant Glass Polyester Enclosures Dimensions — Inches/mm (Figure 11) No. NEMA Class Type of Fig. Size Poles A B C D E IN mm IN mm IN mm IN mm IN 0, 1 2 8502 & SBW All SCW 8536 8502 & SDW All 8536 F mm IN G mm IN H mm IN I mm IN J mm IN K mm IN L mm IN mm Bot. Top & Hub Bot. Only Hub Wt (Lbs) W X 10A 6.50 165 6.44 164 12.13 308 .75 19 5.00 127 8.75 222 1.69 43 3.34 85 10.06 256 1.31 33 2.13 54 .31 8 3⁄4 1 17 10B 8.50 216 7.06 179 13.88 353 .75 19 7.00 179 10.50 267 1.69 43 3.91 99 11.94 303 1.63 41 2.38 60 .31 8 3⁄4 11⁄2 22 10.13 257 21.50 546 . . . ... ... ... ... ... ... ... ... ... ... ... ... ... ... 18.50 470 32.25 819 . . . ... ... ... ... ... ... ... ... ... ... ... ... ... ... SBW 8502 & 0-2t SCW All 10B 16.88 429 9.78 248 22.75 578 . . . . . . 8536 SDW 8502 & SEW 3-4j All 10B 25.81 656 11.94 303 33.50 851 . . . . . . SFW 8536 t With control power transformer (Form F4T). j Dimensions also for Form F4T. A E G F B D C L H X W K I J Figure 11 NEMA Type 9 Enclosures for Hazardous Locations — Sheet Steel Dimensions — Inches/mm (Figure 11) No. of NEMA A B C D E Type Poles Size IN mm IN mm IN mm IN mm IN F mm IN G H mm IN mm IN I mm IN J mm IN K mm IN mm 0 1 SBE SCE 2-4 8.84 225 8.22 209 13.00 330 12.00 305 6.00 152 1.38 35 .50 13 14.69 373 3.91 99 2.13 54 2.00 51 2 SDE 2-4 10.34 263 8.97 228 16.13 410 15.00 381 7.50 191 1.38 35 .56 14 16.94 430 3.91 99 2.75 70 2.38 60 3 SEE 2-4 12.84 326 9.72 247 24.16 614 22.25 565 9.00 229 1.88 48 .97 25 20.56 522 4.41 112 3.25 83 2.88 73 4 SFE 2-4 15.84 402 9.72 247 34.16 868 32.25 819 12.00 305 1.88 48 .97 25 23.56 598 4.41 112 3.25 83 2.88 73 X Bot. Only W Top & Bot. 3⁄4" 1" 241⁄2 Dia. Hub Dia. Hub 3⁄4" Dia. Hub 3⁄4" Dia. Hub 3⁄4" Dia. Hub 11⁄2" 311⁄4 Dia. Hub 2" 54 Dia. Hub 21⁄2" 74 Dia. Hub NOTE: Devices with Form F4T may use larger enclosure. Consult local Square D Field Office for dimensions. 20 © 1998 Square D All Rights Reserved Wt (Lbs) 5/98 Full Voltage Contactors and Starters — NEMA Approximate Dimensions, Shipping Weights – Class 8502, 8536 NEMA Type 7 & 9 Enclosures for Hazardous Locations Sizes 0-2, Bolted Cover, Cast Iron, Sizes 0-5, Bolted Cover, Cast Aluminum, Sizes 0-5, SPIN TOP®, Cast Aluminum Top View Rear View Space Required To Remove Top Cover 12.00 11.00 (1) 1-11 1/2 Pipe Tap at Top Std. 279 .63 9.75 248 9.25 16 235 2.40 4.90 61 260 2.40 .25 178 16 125 10.75 273 10.25 16 7.00 .63 .25 191 16 149 E Q 7.50 .63 5.88 61 6 N (1) 1-11 1/2 Pipe Tap at Top Std. 305 .63 6 (2) "L" Pipe Tap Top and Bottom Optional Mounting Optional Mounting 7.90 12.70 13.25 337 9.63 14.44 201 323 12.00 210 Figure 12 Size 0 and 1 235 A C B D F H S K L M J T Mtg. Holes and/or Slots (3) Circuit Breaker Operational Handle – Combination Form Only P (Add 1.00 Inch To Overall Width) Overload Reset (4) .42 Dia. Mounting Holes 10 (1) 1 1/2 - 11 1/2 Pipe Tap at Bottom Std. 9.25 (1) 3/4 - 14 Pipe Tap at Bottom Std. G Threaded Cover Enclosure 349 (4) .42 Dia. Mounting Holes 10 (1) 1 - 11 1/2 Pipe Tap at Bottom Std. 8.25 381 13.75 305 (1) 3/4 - 14 Pipe Tap at Bottom Std. 15.00 245 367 Rear Seal R Space Required To Remove Bottom Cover Figure 13 Size 2 Figure 14 Size 0-5 NEMA 7 & 9 Bolted Cover, Cast Iron NEMA Size 0, 1 2 Type SBT SCT SDT Dimensions — Inches/mm A B C D E F G H J K L M N P Wt (Lbs) R See Figure 12 59 See Figure 13 75 NEMA 7 & 9 SPIN TOP ® Enclosure – Figure 14 Dimensions — Inches/mm NEMA Type Size A Bt Bj Ct Cj D Et Ej F G Ht Hj J K L M N P R SBR SCR 10.63 270 25.06 637 30.06 764 34.69 881 47.69 1211 14.69 373 6.25 159 11.25 286 7.69 195 11.13 283 2.00 51 9.00 229 7.63 194 7.38 187 2.06 52 9.38 238 5.25 133 1.25 32 .38 10 2 SDR 12.00 305 29.31 744 34.31 871 42.81 1087 54.81 1392 16.75 425 6.75 171 11.75 298 7.69 195 14.75 375 3.00 76 9.00 229 11.50 292 8.50 216 2.06 52 9.38 238 5.25 133 1.50 38 .38 10 3-4 SER SFR 16.13 410 20.75 527 37.50 953 62.13 1578 40.50 1029 62.13 1578 60.00 1524 103.63 2632 66.50 1689 103.63 2632 20.25 514 25.75 654 8.63 219 24.13 613 11.63 295 24.13 613 8.63 219 13.88 353 20.25 514 24.13 613 4.50 114 20.00 508 8.00 203 20.00 508 18.00 457 21.50 546 12.00 305 14.38 365 2.63 67 4.75 121 11.00 279 17.00 432 5.50 140 8.00 203 2.50 64 4.00 102 .50 13 .63 16 0-1 5 t j SGR Wt (Lbs) 70 100 165 195 375 Without control transformer. With control transformer (Form F4T) NEMA 7 & 9 Bolted Cover, Cast Aluminum V U O Circuit Breaker Handle not supplied on Class 8502 or 8536 H 1/2" NPT for Breather and Drain L K N R S T G J P Mounting for 4 Bolts Figure 15 Dimensions — Inches/mm NEMA H Type G Size IN mm IN mm 0-1 2 3-4 5 SBT SCT SDT SET SFT SGT J IN Wt (Lbs) mm K IN mm L IN mm N IN mm P IN mm Q, R IN mm S, T, U, V IN mm 14.25 362 17.25 438 9.50 241 12.25 311 8.88 226 4.50 114 11.00 279 2.38 60 3.13 80 75 13.63 346 27.63 702 9.50 241 12.25 311 19.25 489 9.63 245 11.00 279 2.38 60 3.13 80 115 18.13 461 13.63 346 10.00 254 16.25 413 19.25 489 9.63 245 12.63 321 2.38 60 3.75 95 180 24.50 622 45.63 1159 13.75 349 22.50 572 27.50 699 13.75 349 15.38 391 3.44 87 4.00 102 500 21 5/98 © 1998 Square D All Rights Reserved Full Voltage Contactors and Starters — NEMA Approximate Dimensions, Shipping Weights – Class 8502, 8536 D A E D NEMA Type 12 — Dusttight Enclosure G F C NEMA Class Size Type 0 SBA Dimensions – Inches/mm (Figure 16) No. of B C D E F Poles A 8502 & 8536 1 SCA I 2 8502 & 8536 SDA 3 H Figure 16 NEMA Type 12 Industrial Use Enclosure D A E D G F C I I J Class Class 8502 8536 8.53 217 12.75 324 1.56 40 3.25 83 12.00 305 .38 10 3.56 90 12.25 311 .31 8 15 16 All 8.13 207 9.28 236 16.00 406 1.56 40 5.00 127 15.00 381 .50 13 3.56 90 15.38 391 .31 8 22 23 18.16 461 9.56 243 31.50 800 3.08 78 12.00 305 30.50 775 .50 13 4.50 114 26.72 679 .44 11 65 68 All 4 SFA 5 8502 & 8536 SGA All 17.22 437 13.44 341 47.00 1194 4.13 105 9.00 229 46.00 1168 .50 13 5.41 137 28.31 719 6 8502 & 8536 SHA All 20.22 514 13.00 330 65.00 1651 4.13 105 12.00 305 64.00 1626 .50 13 6.44 164 30.88 784 7 8502 & 8536 SJA All 34.50 876 23.50 597 93.00 2362 Floor Mounting 69 73 .56 14 160 177 .69 18 228 233 ... ... NEMA Type 12 — Dusttight Enclosure with Form F4T NEMA Class Size Dimensions – Inches/mm (Figure 17) No. A B C D E Type of Poles IN mm IN mm IN mm IN mm IN 0 SBA 8502 & 8536 B G (4) J Dia. Mounting Holes H 6.38 162 SEA 8502 & 8536 G All B G (4) J Dia. Mounting Holes Weight (Lbs) 1 SCA 2 8502 & 8536 SDA 3 SEA 8502 & 8536 4 F mm IN G H I mm IN mm IN J mm IN mm IN mm All 11.88 302 8.00 203 13.50 343 2.81 71 6.75 171 12.75 324 .38 10 3.91 99 18.38 467 .31 8 All 14.88 378 8.13 207 16.00 406 2.56 65 9.75 248 15.00 381 .38 10 3.66 93 21.50 546 .31 8 2–3 SFA Same as Standard NEMA Type 12 dimensions, see above. 5 8502 & 8536 SGA All 6 8502 & 8536 SHA All 7 8502 & 8536 SJA H Figure 17 NEMA Type 12 Industrial Use Enclosure D A E D G F C Form F4T is supplied as standard. Refer to Page 16. NEMA Type 3R — Rainproof and Sleet Resistant Enclosures Dimensions — Inches/mm (Figure 17) No. NEMA Class Type of Size B C D1 D2 E F G1 G2 H1 H2 J Poles A 0&1 B G (4) J Dia. Mounting Holes I 2 3 H Figure 18 NEMA Type 3R Outdoor Use Enclosure All 4 8502 & SBH, All 8536 SCH 8502 & SDH 8536 All 8502 & SEH 8536 All 8502 & SFH 8536 All 8.84 225 12.28 7.13 1.38 1.44 6.00 312 181 35 37 152 7.50 191 K L 2.59 2.19 2.06 2.63 14.28 1.38 1.38 66 56 52 67 363 35 35 M N P K.O. K.O. X Y 1⁄2 1.88 4.38 1.84 3 ⁄4 48 111 47 1 11.50 2.59 2.19 2.06 2.63 16.78 1.31 1.75 292 66 56 52 67 426 33 44 1 2.13 4.88 1.84 1 1 ⁄4 54 124 47 11⁄2 12.84 25.28 8.63 1.38 1.44 10.00 20.50 2.59 2.19 2.06 2.63 19.78 1.31 1.94 326 642 219 35 37 254 521 66 56 52 67 502 33 49 1 2.44 6.38 1.84 11⁄4 62 162 47 2 21⁄2 9.84 250 16.28 8.63 1.38 1.44 7.00 414 219 35 37 178 12.84 40.28 9.13 1.38 1.44 10.00 35.50 2.59 2.19 2.06 2.63 20.28 1.31 2.31 326 1023 232 35 37 254 902 66 56 52 67 515 33 59 1 2.69 6.38 1.84 11⁄4 68 162 47 2 21⁄2 22 © 1998 Square D All Rights Reserved 5/98 1⁄2 3⁄4 1 1⁄2 3⁄4 1⁄2 3⁄4 1⁄2 3⁄4 Full Voltage Contactors — NEMA Application Data Altitude Electrical Ratings Characteristic Size 4 Size 5 Size 6 40 50 75 100 100 75 100 150 200 200 150 200 300 400 400 80 160 200 160 320 400 Maximum Motor HP at: 200 V 230 V 380 V 460 V 575 V The vacuum contactor is designed to tolerate normal barometric pressure variances up to 6600 feet above sea level. If the contactor is to be used above 6600 feet above sea level, please consult the factory. 3 Phase Capacitor Switching – KVAR 230 V 460 V 575 V 40 80 100 Transformer Switching – KVA 3 Phase, 3-Pole Class 8502 Type WF Vacuum Contactor 240 V 480 V 600 V 23 47 59 47 94 117 94 188 234 Coil Data Inrush VA Sealed VA Sealed Watts Pick-up Volts Drop-out Volts Pick-up Time (ms) Drop-out Time (ms) 300 600 30 20 6 20 70% of rated coil voltage 50% of rated coil voltage 18-22 24-32 90-120 96-100 1450 32 30 24-32 96-100 Additional Electrical Characteristics Number of Poles Max. Voltage Rating Enclosed Ampere Rating Max. Closing Current Max. Interrupting Current Short Time Current (RMS): 1 second 2 seconds Dielectric Strength, volts Max. Allowable Interrupting Impulse Voltage, VA (1 x 40ms) 3 600 135 1600 1600 3 600 270 3000 3000 3 600 540 6000 6000 2400 1600 5375 1200/hr 15000 4500 3000 5375 1200/hr 15000 9000 6000 5375 1200/hr 15000 General Information Class 8502 Type W non-reversing vacuum contactors are a new addition to the Square D line of contactors. These contactors are used to switch capacitors, transformers and electric motors where overload protection is separately provided. Type W vacuum contactors are designed for operation at 600 Volts, 50/60 Hertz. File E78351 CCN NLDX2 LR75167, 75168 Class 3211-04 By design, these contactors are well suited to heavy-duty applications in harsh environments. The power contacts are sealed in ceramic tubes, called vacuum interrupters or vacuum bottles, where the air has been evacuated. Arc quenchers are not required because any arc formed between opening contacts is not sustained due to the presence of the vacuum. The arc is extinguished when the current crosses zero after the contacts are opened, therefore the arc typically does not survive more than one half cycle. There is one vacuum interrupter or bottle per pole, therefore a three pole contactor has three vacuum interrupters or bottles. The power contacts are not affected by ambient conditions or contamination. This provides for long life and reliable operation in harsh applications. Termination Means The Size 4 vacuum contactor is supplied with line and load side lugst. The Size 5 and 6 vacuum contactors are supplied without line and load side lugs. Class 9999 Type LUW5 and LUW6 lug kits are available for the Size 5 and 6 contactors. These kits include six lugs and the necessary mounting hardware. Auxiliary Contacts An auxiliary contact block, Class 9999 Type WX11, with one normally-open contact and normally-closed contact is used with the Size 4, 5 and 6 vacuum contactors. Auxiliary Contact Units Auxiliary contact units may be added in the field. the table below shows the maximum number of units that may be added to a given size contactor (in addition to the coil auxiliary contact). Class 8502 Size 4 Size 5 Size 6 3 4 4 Terminals Size Power Terminals Wire Sizeq Min. – Max. Control Terminals Wire Sizeq Min. – Max. 4 #12-4/0 #16-12 5c One #0-500 kcmil per phase #16-12 6c Two #0-500 kcmil per phase #16-12 c q Power terminal lugs are not supplied on Size 5 and 6 contactors. Values in table reflect those for the Size 5 and 6 lug kits, Class 9999 Type LUW5 and LUW6 respectively. Solid or stranded copper wire. 23 5/98 © 1998 Square D All Rights Reserved Full Voltage Contactors — NEMA Selection – Class 8502 Class 8502 – Full Voltage Vacuum Contactors NEMA Size Enclosed Ampere Rating NEMA Type 1 General Purpose Enclosure NEMA Type 4 & 4X Watertight, Dusttight Brushed Stainless Steel Enclosure (Size 4 & 5 only) NEMA Type 12 Dusttight & Driptight Industrial Use Enclosure Locked Rotor Current (Amps) Motor Volts Max. HP t Coil Voltage Type Type Type Type 40 50 75 100 100 120 240 120 480 600 WFO3V02S WFO3V03 WFO3V02S WFO3V06 WFO3V07 WFG3V02S WFG3V03 WFG3V002S WFG3V06 WFG3V07 WFW3V02S WFW3V03 WFW3V02S WFW3V06 WFW3V07 WFA3V02S WFA3V03 WFA3V02S WFA3V06 WFA3V07 Open Type 4 135 1080 200 230 380 460 575 5 270 2160 200 230 380 460 575 75 100 150 200 200 120 240 120 480 600 WGO3V02S WGO3V03 WGO3V02S WGO3V06 WGO3V07 WGG3V02S WGG3V03 WGG3V002S WGG3V06 WGG3V07 WGW3V02S WGW3V03 WGW3V02S WGW3V06 WGW3V07 WGA3V02S WGA3V03 WGA3V02S WGA3V06 WGA3V07 6 540 4320 200 230 380 460 575 150 200 300 400 400 120 240 120 480 600 WHO3V02S WHO3V03 WHO3V02S WHO3V06 WHO3V07 WHG3V02S WHG3V03 WHG3V002S WHG3V06 WHG3V07 WHW3V02S WHW3V03 WHW3V02S WHW3V06 WHW3V07 WHA3V02S WHA3V03 WHA3V02S WHA3V06 WHA3V07 t Consult factory for availability of enclosed devices. 6.13 .38 10 156 1.88 .94 Front View Shown Without Overtravel Gauge 48 24 5.22 3.60 Recess for Auxiliary Contact 133 Line Term. 91 12.50 318 7.28 6.63 152 .28 Dia. 7 (3) Mtg. Holes 168 1.44 1.44 .94 1.88 Overtravel Gauge 6.00 37 24 48 129 Load Term. 149 118 64 1.45 37 5.93 Side View 227 2.50 2.50 5.09 5.87 37 4.63 Rear View Drilling Plan 8.94 185 7.90 201 151 Front View Side View Class 8502 Type WF 64 Front View Class 8502 Type WG 1 2 7.00 178 5.00 Two Dual Circuit Interlocks. Located on both sides of contactor when used. 2.67 2.67 68 127 Coil Interlock Coil Terminals located on both sides of contactor. 68 .33 x .75 8 19 Key Holes 8.75 12.90 1 328 Term. Holes 222 8.00 2 203 13.99 355 .33 Slot 8 (2 Places) .38 10 6.75 171 Rear View Drilling Plan .58 15 3.72 1.28 33 94 Side View 2.67 2.67 68 68 7.90 201 Front View Class 8502 Type WH 24 © 1998 Square D All Rights Reserved 5/98 Contents SECTION 2 – REVERSING MAGNETIC STARTERS AND CONTACTORS Application Data – Class 8702, 8736 . . . . . . . . . . . . . . . . . . . . . . . . . . 27-28 Selection – Class 8702 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29-30 Selection – Class 8736 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31-32 Application Data – Class 8702, 8736 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33 Approximate Dimensions – Class 8702, 8736 . . . . . . . . . . . . . . . . . . . 34-36 Application Data, Selection – Class 8702 Vacuum Contactor . . . . . . . . . . 37 Selection – Class 8702 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 25 5/98 © 1998 Square D All Rights Reserved 26 © 1998 Square D All Rights Reserved 5/98 Full Voltage Reversing Contactors and Starters — NEMA Application Data – Class 8702, 8736 Size 00, 0, 1 Reversing Contactor AC MAGNETIC REVERSING CONTACTORS CLASS 8702 ambient insensitive and features phase loss, phase unbalance and over-current protection. General Information MOTOR LOGIC™ Solid State Overload Relay (SSOLR) Class 8702 Type S reversing magnetic contactors are used for starting, stopping, and reversing AC motors where overload protection is separately provided. Class 8702 reversing contactors are available in NEMA Sizes 00-7. Class 8702 reversing contactors consist of two Class 8502 contactors mechanically and electrically interlocked. Open type devices, Sizes 0-5 are available in either horizontal or vertical arrangements. Sizes 00, 6, and 7 are available as horizontal only. Enclosed devices, Size 00-7 use horizontally arranged components. Type S reversing contactors are designed for operation at 600 Volts AC, 50-60 Hertz. AC MAGNETIC REVERSING STARTERS CLASS 8736 General Information Size 00, 0, 1 Reversing Starter Solid state overload relays are available for Sizes 00-7 starters. These ambient insensitive overload relays provide phase loss protection, phase unbalance protection and LED power indicator. For additional information see the Class 9065 catalog section. To order Type S starters with solid state overload relays, see Factory Modification (FORMS). Bimetallic overload relays are also available for Sizes 0-6. Ambient Compensated and Noncompensated versions are supplied with manual and automatic reset, trip current adjustment, and an alarm contact on Sizes 0-2. For additional information, see the Class 9065 catalog section. To order Type S starters with bimetallic overload relays, see Factory Modifications (FORMS). Enclosures Class 8736 Type S reversing magnetic starters are used for full voltage starting, stopping, and reversing AC squirrel cage motors. Class 8736 reversing starters are available in NEMA Sizes 00-7. Class 8736 reversing starters consist of one Class 8502 contactor and one Class 8536 starter mechanically and electrically interlocked. Open type devices, Sizes 0-5 are available in either horizontal or vertical arrangements. Sizes 00, 6, and 7 are available as horizontal only. Enclosed devices use horizontally arranged components. Motor overload protection is provided by melting alloy type thermal overload relays. Type S starters are designed for operation at 600 Volts AC, 50-60 Hertz. Overload Relays Class 8736 Type S Size 00-6 reversing starters are provided with melting alloy thermal overload relay as standard. Interchangeable thermal units are available in standard trip Sizes 00-6, quick trip Sizes 00-4, and slow trip Sizes 00-3. Single phase starters use one thermal unit, three phase starters use three thermal units. Class 8702 and 8736 reversing magnetic contactors and starters are available in the following enclosures: • NEMA Type 1 General Purpose Enclosure • NEMA Type 4 & 4X Watertight and Dusttight • NEMA Type 7 & 9 Bolted and Spin-Top for Hazardous Locations • NEMA Type 12 Dusttight and Driptight for Industrial Use The NEMA Type 4 and 4X stainless steel enclosure (Sizes 0-5) has a brushed finish. For an electropolished finish, specify Form G16 and add 15% to the price of the standard device. Sizes 6 and 7 are painted sheet steel and are rated NEMA Type 4 only. Also, NEMA Type 12 devices are available UL Listed for use in Class II, Division 2, Group G and Class III, Divisions 1 and 2 locations. Request Form G21, no additional charge. Separate enclosures are available, see Class 9991. Class 8736 Size 7 starters are provided with solid state overload Motor Logic, which has selectable trip Class 10/20, Ground Fault Detection, and Communication capabilities for future enhancements. The solid state overload relay is 27 5/98 © 1998 Square D All Rights Reserved Full Voltage Reversing Contactors and Starters — NEMA Application Data – Class 8702, 8736 Holding Circuit Contact Mechanical Interlocks Two normally open holding circuit contacts are provided on all reversing contactors and starters as standard. Sizes 00-2 contactors use a Class 9999 SX11 auxiliary contact as the holding circuit contact. Sizes 3-7 contactors use a Class 9999 SX6 auxiliary contact as the holding circuit contact. Additionally, two normally closed auxiliary contacts are provided as standard and wired to prevent energization of both coils at the same time. Sizes 00-2 use a Class 9999 SX12 auxiliary contact while Sizes 3-7 use a Class 9999 SX7 auxiliary contact for this purpose. See Class 9999, for the holding circuit contact electrical ratings. Mechanical interlocks are available for replacement or field assembly of Type S reversing contactors and starters (Sizes 00-4 ONLY). See Class 9999 for additional information. Auxiliary Contacts Additional auxiliary contacts may be added to Type S reversing contactors and starters. See Page 33 for maximum number of auxiliary units and Form designations for factory installed auxiliary contacts. See Class 9999 for auxiliary contact kits for field installation. Type S Accessories Coil Voltages AC coils are available for application on 50-60 Hertz. NEMA Sizes 00-5 are supplied with coils that are designed to operate satisfactorily on line voltages of 85%-110% of rated voltage. NEMA Size 6 and 7 contactors are supplied with a DC coil operated by a solid state rectifier circuit that is powered by an AC source. Additional accessories such as power poles, pneumatic timer attachments, and cover mounted control stations are available as factory or field modifications. Please note that Voltage Codes have been added to the Type designations in order to improve customer service. It is necessary to include the Voltage Code when ordering contactors and starters. Also, 120 Volt Polyphase reversing contactors and starters will be wired for separate control. File E78351 CCN NLDX File LR60905 Class 3211-04 28 © 1998 Square D All Rights Reserved 5/98 Full Voltage Reversing Contactors — NEMA Selection – Class 8702 3-Pole Polyphase — 600 Volts AC Maximum — 50-60 Hertz NEMA Continuous Motor Max. Size Current Ratings Volts HP 00 0 1 2 3 4 5 6 7 f j t NEMA Type 4 & 4X NEMA Type 1 Watertight, Dusttight General Brushed Stainless Purpose Steel Enclosure Enclosure (Sizes 0-5)f Open Type t Coil Voltage Vertical Horizontal Type Type Type Type NEMA Type 12 NEMA Type 7 & 9 Dusttight & Hazardous Locations Driptight Class I, Groups C & D Industrial Use Class II, Groups E, F & G Enclosure Bolted Type SPIN TOP ® Type Aluminum Type Separate Controlj 120 ... SAO4V02S SAG4V02S 208 ... SAO4V08 SAG4V08 200 11⁄2 230 11⁄2 240 ... SAO4V03 SAG4V03 Use Size 0 Use Size 0 Use Size 0 Use Size 0 460 2 480 ... SAO4V06 SAG4V06 575 2 600 ... SAO4V07 SAG4V07 Separate Controlj 120 SBO12V02S SBO4V02S SBG4V02S SBW14V02S SBT49V02S SBR9V02S SBA4V02S 200 3 208 SBO12V08 SBO4V08 SBG4V08 SBW14V08 SBT49V08 SBR9V08 SBA4V08 230 3 240 SBO12V03 SBO4V03 SBG4V03 SBW14V03 SBT49V03 SBR9V03 SBA4V03 18 460 5 480 SBO12V06 SBO4V06 SBG4V06 SBW14V06 SBT49V06 SBR9V06 SBA4V06 575 5 600 SBO12V07 SBO4V07 SBG4V07 SBW14V07 SBT49V07 SBR9V07 SBA4V07 Separate Controlj 120 SCO7V02S SCO8V02S SCG8V02S SCW14V02S SCT49V02S SCR9V02S SCA4V02S 1 200 7 ⁄2 208 SCO7V08 SCO8V08 SCG8V08 SCW14V08 SCT49V08 SCR9V08 SCA4V08 27 240 SCO7V03 SCO8V03 SCG8V03 SCW14V03 SCT49V03 SCR9V03 SCA4V03 230 71⁄2 460 10 480 SCO7V06 SCO8V06 SCG8V06 SCW14V06 SCT49V06 SCR9V06 SCA4V06 575 10 600 SCO7V07 SCO8V07 SCG8V07 SCW14V07 SCT49V07 SCR9V07 SCA4V07 Separate Controlj 120 SDO1V02S SDO2V02S SDG2V02S SDW11V02S SDT43V02S SDR3V02S SDA1V02S 200 10 208 SDO1V08 SDO2V08 SDG2V08 SDW11V08 SDT43V08 SDR3V08 SDA1V08 45 230 15 240 SDO1V03 SDO2V03 SDG2V03 SDW11V03 SDT43V03 SDR3V03 SDA1V03 460 25 480 SDO1V06 SDO2V06 SDG2V06 SDW11V06 SDT43V06 SDR3V06 SDA1V06 575 25 600 SDO1V07 SDO2V07 SDG2V07 SDW11V07 SDT43V07 SDR3V07 SDA1V07 Separate Controlj 120 SEO1V02S SEO2V02S SEG2V02S SEW11V02S SET43V02S SER3V02S SEA1V02S 200 25 208 SEO1V08 SEO2V08 SEG2V08 SEW11V08 SET43V08 SER3V08 SEA1V08 90 230 30 240 SEO1V03 SEO2V03 SEG2V03 SEW11V03 SET43V03 SER3V03 SEA1V03 460 50 480 SEO1V06 SEO2V06 SEG2V06 SEW11V06 SET43V06 SER3V06 SEA1V06 575 540 600 SEO1V07 SEO2V07 SEG2V07 SEW11V07 SET43V07 SER3V07 SEA1V07 Separate Controlj 120 SFO1V02S SFO3V02S SFG3V02S SFW11V02S SFA1V02S 200 40 208 SFO1V08 SFO3V08 SFG3V08 SFW11V08 SFA1V08 135 230 50 240 SFO1V03 SFO3V03 SFG3V03 SFW11V03 ... ... SFA1V03 460 100 480 SFO1V06 SFO3V06 SFG3V06 SFW11V06 SFA1V06 575 100 600 SFO1V07 SFO3V07 SFG3V07 SFW11V07 SFA1V07 Separate Controlj 120 SGO1V02S SGO3V02S SGG3V02S SGW11V02S SGA1V02S 200 75 208 SGO1V08 SGO3V08 SGG3V08 SGW11V08 SGA1V08 270 230 100 240 SGO1V03 SGO3V03 SGG3V03 SGW11V03 ... ... SGA1V03 460 200 480 SGO1V06 SGO3V06 SGG3V06 SGW11V06 SGA1V06 575 200 600 SGO1V07 SGO3V07 SGG3V07 SGW11V07 SGA1V07 Separate Controlj 120 SHO1V02S SHG1V02S SHW1V02S SHA1V02S 200 150 208 SHO1V08 SHG1V08 SHW1V08 SHA1V08 540 ... ... ... 230 200 240 SHO1V03 SHG1V03 SHW1V03 SHA1V03 460 400 480 SHO1V06 SHG1V06 SHW1V06 SHA1V06 575 400 600 SHO1V07 SHG1V07 SHW1V07 SHA1V07 Separate Controlj 120 SJO1V02S SJG1V02S SJW1V02S SJA1V02S 200 — 208 SJO1V08 SJG1V08 SJW1V08 SJA1V08 810 ... ... ... 230 300 240 SJO1V03 SJG1V03 SJW1V03 SJA1V03 460 600 480 SJO1V06 SJG1V06 SJW1V06 SJA1V06 575 600 600 SJO1V07 SJG1V07 SJW1V07 SJA1V07 Size 6 and 7 are rated NEMA Type 4 only. 120 Volt Polyphase contactors are wired for separate control. Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed in selection table above or additional standard voltage codes below and insert as shown in the HOW TO ORDER block. 9 Coil Voltage Codes Voltage 60 Hz 50 Hz 24q 120 208 240 480 600 Specify ... 110 ... 220 440 550 Specify q j Code V01jq V02j V08 V03 V06 V07 V99 24 V coils are not available on Sizes 4-7. On Sizes 00-3, where 24 V coils are available, Form S (separate control) must be specified. These voltage codes must include Form S (supplied at N.C.). How to Order: To Order Specify: • Class Number • Type Number • Coil Voltage Code • Form(s) Catalog Number Class Type Coil Voltage Code Form(s) 8702 SCG8 VO2 P1S Factory Modifications (FORMS)............... Refer to Catalog 9999CT9701 Application Data .....................................................................Page 33, 37 Dimensions ............................................................................Pages 34-36 Separate Enclosures (Class 9991)........... Refer to Catalog 9999CT9701 Replacement Parts (Class 9998) .............. Refer to Catalog 9999CT9701 Type S Accessories (Class 9999)............. Refer to Catalog 9999CT9701 29 5/98 © 1998 Square D All Rights Reserved Full Voltage Reversing Contactors — NEMA Selection – Class 8702 600 Volts AC Maximum — 50-60 Hertz Continuous Motor NEMA Current Volts Size Ratings Max. HP NEMA Type 1 General Purpose Enclosure Open Type t Type of Coil Motor Voltage Vertical Horizontal Type Type Type NEMA Type 4 & 4X Watertight, Dusttight Brushed Stainless Steel Enclosure Type NEMA Type 12 NEMA Type 7 & 9 Dusttight & Hazardous Locations Driptight Class I, Groups C & D Industrial Use Class II, Groups E, F & G Enclosure SPIN TOP ® Bolted Type Type Type 2-Pole Single Phase 00 9 0 18 1 27 115 230 115 230 115 230 1⁄3 115 230 115 230 115 230 115 230 115 230 115 230 1⁄3 1 1 2 2 3 Single Phase 3-Wire 120 240 120 240 120 240 ... ... SBO9V02 SBO9V03 SCO1V02 SCO1V03 SAO1V02 SAO1V03 SBO1V02 SBO1V03 SCO2V02 SCO2V03 SAG1V02 SAG1V03 SBG1V02 SBG1V03 SCG2V02 SCG2V03 4-Wire Rep.-Ind. 4-Wire Split Ph. 4-Wire Rep.-Ind. 4-Wire Split Ph. 4-Wire Rep.-Ind. 4-Wire Split Ph. 120 240 120 240 120 240 120 240 120 240 120 240 ... ... ... ... SBO10V02 SBO10V03 SBO11V02 SBO11V03 SCO3V02 SCO3V03 SCO5V02 SCO5V03 SAO2V02 SAO2V03 SAO3V02 SAO3V03 SBO2V02 SBO2V03 SBO3V02 SBO3V03 SCO4V02 SCO4V03 SCO6V02 SCO6V03 SAG2V02 SAG2V03 SAG3V02 SAG3V03 SBG2V02 SBG2V03 SBG3V02 SBG3V03 SCG4V02 SCG4V03 SCG6V02 SCG6V03 Use Size 0 Use Size 0 Use Size 0 Use Size 0 SBW11V02 SBW11V03 SCW11V02 SCW11V03 SBT46V02 SBT46V03 SCT46V02 SCT46V03 SBR6V02 SBR6V03 SCR6V02 SCR6V03 SBA1V02 SBA1V03 SCA1V02 SCA1V03 Use Size 0 Use Size 0 Use Size 0 Use Size 0 Use Size 0 Use Size 0 Use Size 0 Use Size 0 SBW12V02 SBW12V03 SBW13V02 SBW13V03 SCW12V02 SCW12V03 SCW13V02 SCW13V03 SBT47V02 SBT47V03 SBT48V02 SBT48V03 SCT47V02 SCT47V03 SCT48V02 SCT48V03 SBR7V02 SBR7V03 SBR8V02 SBR8V03 SCR7V02 SCR7V03 SCR8V02 SCR8V03 SBA2V02 SBA2V03 SBA3V02 SBA3V03 SCA2V02 SCA2V03 SCA3V02 SCA3V03 3-Pole Single Phase 00 9 0 18 1 27 1 1⁄3 1 1 2 1 2 2 3 2 3 4-Pole Polyphase 0 1 2 3 4 t SBR10V02S SBA5V02S Separate Control 120 SBO13V02S SBO5V02S SBG5V02S SBW15V02S 200 3 208 SBO13V08 SBO5V08 SBG5V08 SBW15V08 SBA5V08 Consult Local SBR10V08 230 3 240 SBO13V03 SBO5V03 SBG5V03 SBW15V03 SBR10V03 SBA5V03 Square D 460 5 480 SBO13V06 SBO5V06 SBG5V06 SBW15V06 Field Office SBR10V06 SBA5V06 575 5 600 SBO13V07 SBO5V07 SBG5V07 SBW15V07 SBR10V07 SBA5V07 SCR10V02S SCA5V02S Separate Control 120 SCO9V02S SCO10V02S SCG10V02S SCW15V02S 1 200 7 ⁄2 Consult Local SCR10V08 208 SCO9V08 SCO10V08 SCG10V08 SCW15V08 SCA5V08 Square D 27 230 71⁄2 240 SCO9V03 SCO10V03 SCG10V03 SCW15V03 SCR10V03 SCA5V03 Field Office 460 10 480 SCO9V06 SCO10V06 SCG10V06 SCW15V06 SCR10V06 SCA5V06 575 10 600 SCO9V07 SCO10V07 SCG10V07 SCW15V07 SCR10V07 SCA5V07 SDR4V02S SDA2V02S Separate Control 120 SDO4V02S SDG4V02S SDW12V02S 200 10 208 SDO4V08 SDG4V08 SDW12V08 SDA2V08 Consult Local SDR4V08 2 Phase 230 15 240 SDO4V03 SDG4V03 SDW12V03 SDR4V03 SDA2V03 Square D 45 ... 2 Wire 460 25 480 SDO4V06 SDG4V06 SDW12V06 SDR4V06 SDA2V06 Field Office 575 25 600 SDO4V07 SDG4V07 SDW12V07 SDR4V07 SDA2V07 Separate Control 120 SEO4V02S SEG4V02S SEW12V02S SEA2V02S 200 25 208 SEO4V08 SEG4V08 SEW12V08 SEA2V08 230 30 240 SEO4V03 SEG4V03 SEW12V03 SEA2V03 90 ... ... ... 460 50 480 SEO4V06 SEG4V06 SEW12V06 SEA2V06 575 50 600 SEO4V07 SEG4V07 SEW12V07 SEA2V07 Separate Control 120 SFO4V02S SFG4V02S SFW12V02S SFA2V02S 200 40 208 SFO4V08 SFG4V08 SFW12V08 SFA2V08 135 230 50 240 ... SFO4V03 SFG4V03 SFW12V03 ... ... SFA2V03 460 100 480 SFO4V06 SFG4V06 SFW12V06 SFA2V06 575 100 600 SFO4V07 SFG4V07 SFW12V07 SFA2V07 Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed in selection table above or additional standard voltage codes below and insert as shown in the HOW TO ORDER block. 18 Coil Voltage Codes Voltage 60 Hz 50 Hz 24q 120 208 240 480 600 Specify ... 110 ... 220 440 550 Specify q j Code V01j V02j V08 V03 V06 V07 V99 File E78351 CCN NLDX File LR60905 Class 3211-04 24 V coils are not available on Sizes 4-7. On Sizes 00-3, where 24 V coils are available, Form S (separate control) must be specified. These voltage codes must include Form S (supplied at N.C.). How to Order: To Order Specify: Factory Modifications (FORMS) ...............Refer to Catalog 9999CT9701 Application Data .................................................................... Page 33, 37 Dimensions ........................................................................... Pages 34-36 Separate Enclosures (Class 9991) ...........Refer to Catalog 9999CT9701 Replacement Parts (Class 9998) ..............Refer to Catalog 9999CT9701 Type S Accessories (Class 9999).............Refer to Catalog 9999CT9701 • Class Number • Type Number • Coil Voltage Code • Form(s) Catalog Number Class Type Coil Voltage Code Form(s) 8702 SCG2 VO2 P1S 30 © 1998 Square D All Rights Reserved 5/98 Full Voltage Reversing Starters — NEMA Selection – Class 8736 3-Pole Polyphase—Three Thermal Units Required Continuous Motor NEMA Current Volts Size Ratings 00 0 1 2 3 4 5 6 7 f j t Max. HP NEMA Type 1 General Purpose Enclosure Open Type t Coil Voltage Vertical Horizontal Type Type Type NEMA Type 4 & 4X Watertight, Dusttight Brushed Stainless Steel Enclosure (Size 0-5)f NEMA Type 7 & 9 Hazardous Locations Class I, Groups C & D Class II, Groups E, F & G Type Bolted Type NEMA Type 12 Dusttight & Driptight Industrial Use Enclosure SPIN TOP ® Type Type Separate Controlj 120 SAO16V02S SAG16V02S 208 SAO16V08 SAG16V08 200 11⁄2 230 11⁄2 240 ... SAO16V03 SAG16V03 Use Size 0 Use Size 0 Use Size 0 Use Size 0 460 2 480 SAO16V06 SAG16V06 575 2 600 SAO16V07 SAG16V07 Separate Controlj 120 SBO10V02S SBO4V02S SBG4V02S SBW14V02S SBT49V02S SBR9V02S SBA4V02S 200 3 208 SBO10V08 SBO4V08 SBG4V08 SBW14V08 SBT49V08 SBR9V08 SBA4V08 230 3 240 SBO10V03 SBO4V03 SBG4V03 SBW14V03 SBT49V03 SBR9V03 SBA4V03 18 460 5 480 SBO10V06 SBO4V06 SBG4V06 SBW14V06 SBT49V06 SBR9V06 SBA4V06 575 5 600 SBO10V07 SBO4V07 SBG4V07 SBW14V07 SBT49V07 SBR9V07 SBA4V07 Separate Controlj 120 SCO7V02S SCO8V02S SCG8V02S SCW14V02S SCT49V02S SCR9V02S SCA4V02S 200 71⁄2 208 SCO7V08 SCO8V08 SCG8V08 SCW14V08 SCT49V08 SCR9V08 SCA4V08 27 240 SCO7V03 SCO8V03 SCG8V03 SCW14V03 SCT49V03 SCR9V03 SCA4V03 230 71⁄2 460 10 480 SCO7V06 SCO8V06 SCG8V06 SCW14V06 SCT49V06 SCR9V06 SCA4V06 575 10 600 SCO7V07 SCO8V07 SCG8V07 SCW14V07 SCT49V07 SCR9V07 SCA4V07 Separate Controlj 120 SDO1V02S SDO2V02S SDG2V02S SDW11V02S SDT43V02S SDR3V02S SDA1V02S 200 10 208 SDO1V08 SDO2V08 SDG2V08 SDW11V08 SDT43V08 SDR3V08 SDA1V08 45 230 15 240 SDO1V03 SDO2V03 SDG2V03 SDW11V03 SDT43V03 SDR3V03 SDA1V03 460 25 480 SDO1V06 SDO2V06 SDG2V06 SDW11V06 SDT43V06 SDR3V06 SDA1V06 575 25 600 SDO1V07 SDO2V07 SDG2V07 SDW11V07 SDT43V07 SDR3V07 SDA1V07 Separate Controlj 120 SEO1V02S SEO2V02S SEG2V02S SEW11V02S SET43V02S SER3V02S SEA1V02S 200 25 208 SEO1V08 SEO2V08 SEG2V08 SEW11V08 SET43V08 SER3V08 SEA1V08 90 230 30 240 SEO1V03 SEO2V03 SEG2V03 SEW11V03 SET43V03 SER3V03 SEA1V03 460 50 480 SEO1V06 SEO2V06 SEG2V06 SEW11V06 SET43V06 SER3V06 SEA1V06 575 50 600 SEO1V07 SEO2V07 SEG2V07 SEW11V07 SET43V07 SER3V07 SEA1V07 Separate Controlj 120 SFO1V02S SFO3V02S SFG3V02S SFW11V02S SFA1V02S 200 40 208 SFO1V08 SFO3V08 SFG3V08 SFW11V08 SFA1V08 135 230 50 240 SFO1V03 SFO3V03 SFG3V03 SFW11V03 ... ... SFA1V03 460 100 480 SFO1V06 SFO3V06 SFG3V06 SFW11V06 SFA1V06 575 100 600 SFO1V07 SFO3V07 SFG3V07 SFW11V07 SFA1V07 Separate Controlj 120 SGO1V02S SGO3V02S SGG3V02S SGW11V02S SGA1V02S 200 75 208 SGO1V08 SGO3V08 SGG3V08 SGW11V08 SGA1V08 270 230 100 240 SGO1V03 SGO3V03 SGG3V03 SGW11V03 ... ... SGA1V03 460 200 480 SGO1V06 SGO3V06 SGG3V06 SGW11V06 SGA1V06 575 200 600 SGO1V07 SGO3V07 SGG3V07 SGW11V07 SGA1V07 Separate Controlj 120 SHO1V02S SHG1V02S SHW1V02S SHA1V02S 200 150 208 SHO1V08 SHG1V08 SHW1V08 SHA1V08 540 ... ... ... 230 200 240 SHO1V03 SHG1V03 SHW1V03 SHA1V03 460 400 480 SHO1V06 SHG1V06 SHW1V06 SHA1V06 575 400 600 SHO1V07 SHG1V07 SHW1V07 SHA1V07 Separate Controlj 120 SJO1V02S SJG1V02S SJW1V02S SJA1V02S 200 — 208 SJO1V08 SJG1V08 SJW1V08 SJA1V08 810 ... ... ... 230 300 240 SJO1V03 SJG1V03 SJW1V03 SJA1V03 460 600 480 SJO1V06 SJG1V06 SJW1V06 SJA1V06 575 600 600 SJO1V07 SJG1V07 SJW1V07 SJA1V07 Size 6 and 7 are sheet steel rated NEMA Type 4 only. 120 Volt Polyphase starters are wired for separate control. Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed in selection table above or additional standard voltage codes below and insert as shown in the HOW TO ORDER block. 9 Coil Voltage Codes Voltage 60 Hz 50 Hz 24q 120 208 240 480 600 Specify ... 110 ... 220 440 550 Specify q Code V01 V02 V08 V03 V06 V07 V99 24 V coils are not available on Sizes 4-7. On Sizes 00-3, where 24 V coils are available, Form S (separate control) must be specified. How to Order: To Order Specify: • Class Number • Type Number • Coil Voltage Code • Form(s) Catalog Number Class Type Coil Voltage Code Form(s) 8736 SCG8 VO2 P1S Factory Modifications (FORMS)............... Refer to Catalog 9999CT9701 Application Data .....................................................................Page 33, 37 Dimensions ............................................................................Pages 34-36 Separate Enclosures (Class 9991)........... Refer to Catalog 9999CT9701 Replacement Parts (Class 9998) .............. Refer to Catalog 9999CT9701 Type S Accessories (Class 9999)............. Refer to Catalog 9999CT9701 31 5/98 © 1998 Square D All Rights Reserved Full Voltage Reversing Starters — NEMA Selection – Class 8736 600 Volts AC Maximum — 50-60 Hertz Continuous Motor NEMA Current Volts Size Ratings Max. HP NEMA Type 1 General Purpose Enclosure Open Type t Type of Coil Motor Voltage Vertical Horizontal Type Type Type 2-Pole Single Phase — 1 Thermal Unit Required 1⁄3 115 00 9 230 1 Single 115 1 0 18 Phase 230 2 3-Wire 115 2 1 27 230 3 3-Pole Single Phase — 1 Thermal Unit Required 1⁄3 4-Wire 115 230 1 Rep.-Ind. 00 9 1⁄3 115 4-Wire 230 1 Split Ph. 115 1 4-Wire 230 2 Rep.-Ind. 0 18 115 1 4-Wire 230 2 Split Ph. 115 2 4-Wire 230 3 Rep.-Ind. 1 27 115 2 4-Wire 230 3 Split Ph. 4-Pole Polyphase — 2 Thermal Units Required Separate Controlj 200 3 230 3 0 18 460 5 575 5 Separate Controlj 200 71⁄2 1 27 230 71⁄2 460 10 575 10 Separate Controlj 200 10 2 Phase 230 15 2 45 2 Wire 460 25 3 4 j t Type 120 240 120 240 120 240 ... ... SBO7V02 SBO7V08 SCO1V02 SCO1V08 SAO13V02 SAO13V08 SBO1V02 SBO1V08 SCO2V02 SCO2V08 SAG13V02 SAG13V08 SBG1V02 SBG1V08 SCG2V02 SCG2V08 120 240 120 240 120 240 120 240 120 240 120 240 ... ... ... ... SBO80V02 SBO8V08 SBO9V02 SBO9V08 SCO3V02 SCO3V08 SCO5V02 SCO5V08 SAO14V02 SAO14V08 SAO15V02 SAO15V08 SBO2V02 SBO2V08 SBO3V02 SBO3V08 SCO4V02 SCO4V08 SCO6V02 SCO6V08 SAG14V02 SAG14V08 SAG15V02 SAG15V08 SBG2V02 SBG2V08 SBG3V02 SBG3V08 SCG4V02 SCG4V08 SCG6V02 SCG6V08 120 208 240 480 600 120 208 240 480 600 120 208 240 480 600 120 208 240 480 600 120 208 240 480 600 SBO11V02S SBO11V08 SBO11V03 SBO11V06 SBO11V07 SCO9V02S SCO9V08 SCO9V03 SCO9V06 SCO9V07 SBO5V02S SBO5V08 SBO5V03 SBO5V06 SBO5V07 SCO10V02S SCO10V08 SCO10V03 SCO10V06 SCO10V07 SDO4V02S SDO4V08 SDO4V03 SDO4V06 SDO4V07 SEO4V02S SEO4V08 SEO4V03 SEO4V06 SEO4V07 SFO4V02S SFO4V08 SFO4V03 SFO4V06 SFO4V07 SBG5V02S SBG5V08 SBG5V03 SBG5V06 SBG5V07 SCG10V02S SCG10V08 SCG10V03 SCG10V06 SCG10V07 SDG4V02S SDG4V08 SDG4V03 SDG4V06 SDG4V07 SEG4V02S SEG4V08 SEG4V03 SEG4V06 SEG4V07 SFG4V02S SFG4V08 SFG4V03 SFG4V06 SFG4V07 ... NEMA Type 4 & 4X Watertight, Dusttight Brushed Stainless Steel Enclosure NEMA Type 12 NEMA Type 7 & 9 Dusttight & Hazardous Locations Driptight Class I, Groups C & D Industrial Use Class II, Groups E, F & G Enclosure SPIN TOP ® Bolted Type Type Type Use Size 0 Use Size 0 Use Size 0 Use Size 0 SBW11V02 SBW11V08 SCW11V02 SCW11V08 SBT46V02 SBT46V08 SCT46V02 SCT46V08 SBR6V02 SBR6V08 SCR6V02 SCR6V08 SBA1V02 SBA1V08 SCA1V02 SCA1V08 Use Size 0 Use Size 0 Use Size 0 Use Size 0 Use Size 0 Use Size 0 Use Size 0 Use Size 0 SBW12V02 SBW12V08 SBW13V02 SBW13V08 SCW12V02 SCW12V08 SCW13V02 SCW13V08 SBT47V02 SBT47V08 SBT48V02 SBT48V08 SCT47V02 SCT47V08 SCT48V02 SCT48V08 SBR7V02 SBR7V08 SBR8V02 SBR8V08 SCR7V02 SCR7V08 SCR8V02 SCR8V08 SBA2V02 SBA2V08 SBA3V02 SBA3V08 SCA2V02 SCA2V08 SCA3V02 SCA3V08 SBR10V02S SBR10V08 SBR10V03 SBR10V06 SBR10V07 SCR10V02S SCR10V08 SCR10V03 SCR10V06 SCR10V07 SDR4V02S SDR4V08 SDR4V03 SDR4V06 SDR4V07 SBA5V02S SBA5V08 SBA5V03 SBA5V06 SBA5V07 SCA5V02S SCA5V08 SCA5V03 SCA5V06 SCA5V07 SDA2V02S SDA2V08 SDA2V03 SDA2V06 SDA2V07 SEA2V02S SEA2V08 SEA2V03 SEA2V06 SEA2V07 SFA2V02S SFA2V08 SFA2V03 SFA2V06 SFA2V07 SBW15V02S SBW15V08 SBW15V03 SBW15V06 SBW15V07 SCW15V02S SCW15V08 SCW15V03 SCW15V06 SCW15V07 SDW12V02S SDW12V08 SDW12V03 SDW12V06 SDW12V07 SEW12V02S SEW12V08 SEW12V03 SEW12V06 SEW12V07 SFW12V02S SFW12V08 SFW12V03 SFW12V06 SFW12V07 Consult Local Square D Field Office Consult Local Square D Field Office Consult Local Square D Field Office 575 25 Separate Controlj 200 25 230 30 90 ... ... ... 460 50 575 50 Separate Controlj 200 40 135 230 50 ... ... ... 460 100 575 100 120 Volt starters are wired for separate control. Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed in selection table above or additional standard voltage codes below and insert as shown in the HOW TO ORDER block. Coil Voltage Codes Voltage 60 Hz 50 Hz 24q 120 208 240 480 600 Specify ... 110 ... 220 440 550 Specify q Code V01 V02 V08 V03 V06 V07 V99 File E78351 CCN NLDX File LR60905 Class 3211-04 24 V coils are not available on Sizes 4-7. On Sizes 00-3, where 24 V coils are available, Form S (separate control) must be specified. How to Order: To Order Specify: Factory Modifications (FORMS) ...............Refer to Catalog 9999CT9701 Application Data .................................................................... Page 33, 37 Dimensions ........................................................................... Pages 34-36 Separate Enclosures (Class 9991) ...........Refer to Catalog 9999CT9701 Replacement Parts (Class 9998) ..............Refer to Catalog 9999CT9701 Type S Accessories (Class 9999).............Refer to Catalog 9999CT9701 • Class Number • Type Number • Coil Voltage Code • Form(s) Catalog Number Class Type Coil Voltage Code Form(s) 8736 SCG8 VO2 P1S 32 © 1998 Square D All Rights Reserved 5/98 Full Voltage Reversing Contactors and Starters — NEMA Application Data – Class 8702, 8736 Power Contact Ratings Auxiliary Units All contactors are rated in accordance with NEMA standards. The ratings shown in the tables on Pages 29-32 are for normal service. For complete data on power contact ratings, refer to Class 8536 Section. The table below shows the maximum number of auxiliary units (in addition to the holding circuit and interlocking contacts) that can be added to either the forward or reverse contactor or starter. Maintenance of Equipment Class 9998 repair parts kits are available for all Class 8702 contactors and Class 8736 starters. Service bulletins with a complete list of replaceable parts are supplied with all devices. See Page 15. The following table gives the proper size control transformer to be used with a given reversing device, with or without additional auxiliary contacts or timer. For factory addition of control transformers, see Factory Modifications (Forms) section. Transformers Class 9070 Type No. of Poles Type 0, 1 & 2 SB, SC & SD Any T100 or GO2 3 T1500 or GO3 3 SE 4&5 T300 4 SF Any T300 5 SG Any T500 6&7 SH & SJ Any See Page 16 Example: X 1 O No. of Poles of Basic Contactor 00 (SA) 2 or 3 2 single circuit auxiliary contacts (N.O. or N.C.) 4 single circuit auxiliary contactsq (N.O. or N.C.) 0, 1 & 2 (SB, SC & SD) Control Transformer Selection NEMA Size NEMA Size (Type) Maximum number of auxiliary units on each contactor, forward or reverse, (in addition to internal holding circuit and interlocking contacts). 1 2 or 3 2 single circuit auxiliary contacts (N.O. or N.C.) 4 3, 4, 5, 6, & 7 (SE, SF, SG, SH, & SJ) q 1 single circuit auxiliary contact (N.O. or N.C.) plus 1 attached timer (ON or OFF delay). 2 single circuit auxiliary contacts (N.O. or N.C.) Any 1 single circuit auxiliary contact plus 1 attached timer (ON or OFF delay). When adding 4 external auxiliary contacts to one Size 0 or 1 contactor, remove one of the return springs. Factory Installed Auxiliary Contacts Additional auxiliary contacts may be factory or field added to any Type 3 contactor or starter. See table above for maximum number of auxiliary units. The table below lists the Form designations for factory installed auxiliary contacts. See Class 9999 for field modification kits. O Number of N.C. auxiliary contacts on right hand (Reverse) contactor. Number of N.O. auxiliary contacts on right hand (Reverse) contactor. Number of N.C. auxiliary contacts on left hand (Forward) contactor. Number of N.O. auxiliary contacts on left hand (Forward) contactor. Basic Form Designation. Additional Auxiliary Contacts on R.H. Contactor (Reverse Contactor) Standard (No Additional Auxiliary Contacts) Additional Auxiliary Contacts on L.H. Contactor (Forward Contactor) Standard (No Additional Auxiliary Contacts) 1 N.O. 1 N.C. 2 N.O. 1 N.O.-1 N.C. 2 N.C. X0010 X0001 X0020 X0011 X0002 1 N.O. X1000 X1010 X1001 X1020 X1011 X1002 1 N.C. X0100 X0110 X0101 X0120 X0111 X0102 2 N.O. X2000 X2010 X2001 X2020 X2011 X2002 1 N.O.-1 N.C. X1100 X1110 X1101 X1120 X1111 X1102 2 N.C. X0200 X0210 X0201 X0220 X0211 X0202 33 5/98 © 1998 Square D All Rights Reserved Full Voltage Reversing Contactors and Starters — NEMA Approximate Dimensions – Class 8702, 8736 Open Type — 2 or 3-Pole Only A D F G E A D C E G F C H I B H B RESET J J Class K NEMA Type Size Mounting Figure Dimensions — Inches/mm Number A B C D 00 Horizontal 1 7.13 181 5.00 127 5.31 135 1 7.13 181 5.00 127 5.31 135 1t 5.41 137 9.22 234 5.31 135 1 9.00 229 6.88 175 6.03 153 1t 6.75 171 11.38 289 6.03 153 1 12.72 323 7.97 202 1t 7.20 183 0 1 SAO SBO SCO Horizontal Vertical Horizontal 2 Horizontal 3 Vertical Horizontal 4 Horizontal 7 00 0 1 SHO SJO SAO SBO SCO Horizontal Horizontal Horizontal Horizontal Vertical Horizontal 2 Horizontal Vertical Horizontal Horizontal 7 t L M Weight (Lbs) ... 3.41 87 .47 12 4.34 110 .19 5 5.50 140 .91 23 ... ... 12 ... ... 3.41 87 .47 12 4.34 110 .19 5 5.50 140 .91 23 ... ... 12 5.03 128 .22 6 ... .61 15 8.00 203 .61 15 5.03 128 .22 6 ... ... 12 ... ... 4.50 114 .38 10 5.63 143 .25 6 6.00 152 1.50 38 ... ... 16 6.25 159 .25 6 ... .50 13 10.38 264 .50 13 6.25 159 .25 6 ... ... 16 7.00 178 11.75 298 .48 12 ... .48 12 7.00 178 .48 12 11.75 298 .48 12 ... ... 35 19.00 483 7.00 178 6.25 159 .48 12 ... 1.02 26 17.00 432 .98 25 6.25 159 .48 12 ... ... 35 1 14.25 362 11.69 297 7.00 178 13.25 337 .50 13 ... .50 13 8.00 203 1.84 47 13.25 337 .50 13 ... ... 45 1t 7.97 202 23.91 607 7.00 178 7.00 178 .48 12 ... 1.81 46 20.25 514 1.19 30 7.00 178 .48 12 ... ... 45 1 19.31 490 16.19 411 9.38 238 18.00 457 .66 17 ... 1.03 26 14.00 356 1.16 29 18.00 457 .66 17 ... ... 98 1t 10.75 273 34.41 874 9.38 238 9.50 241 .63 16 ... 1.25 32 32.00 813 1.16 29 9.50 241 .63 16 ... ... 98 1 22.38 568 28.05 712 9.52 242 18.00 457 .77 20 ... 3.83 97 21.19 538 3.03 77 18.00 457 .77 20 ... ... 195 1 24.25 616 37.25 946 13.81 351 19.75 502 1.52 39 ... ... 30.00 762 ... ... ... ... ... 310 2 7.13 181 6.91 176 5.31 135 ... 3.41 87 .47 12 4.34 110 6.22 158 4.53 115 5.06 129 .66 17 ... 13 2 7.13 181 6.91 176 5.31 135 ... ... 3.41 87 .47 12 4.34 110 6.22 158 4.53 115 5.06 129 .66 17 ... 13 2t 5.41 137 11.52 293 5.31 135 5.03 128 .22 6 ... .61 15 8.00 203 10.70 272 2.52 64 5.06 129 .22 6 5.03 128 13 2 9.00 229 8.50 216 6.03 153 ... ... 4.50 114 .38 10 5.63 143 7.50 191 5.00 127 5.16 131 1.50 38 ... 18 2t 6.75 171 13.48 342 6.03 153 6.25 159 .25 6 ... .78 20 10.38 264 12.97 329 3.13 80 5.16 131 .25 6 6.00 152 18 2 12.72 323 11.72 298 7.00 178 11.75 298 .48 12 ... .48 12 10.75 273 10.75 273 11.75 298 6.25 159 .48 12 11.75 298 38 2t 7.31 186 22.25 565 7.00 178 6.25 159 .48 12 ... 1.02 26 20.75 527 ... 6.25 159 6.25 159 .48 12 6.25 159 38 2 14.25 362 14.59 371 7.00 178 13.25 337 .50 13 ... 1.84 47 12.25 311 12.25 311 13.25 337 6.25 159 .50 13 13.25 337 48 2t 7.97 202 26.81 681 7.00 178 7.00 178 .48 12 ... 1.84 47 24.50 622 ... 4.05 103 6.25 159 .48 12 7.00 178 48 2 19.31 490 20.91 531 9.38 238 18.00 457 .66 17 ... 1.28 33 19.00 483 19.00 483 18.00 457 6.63 168 .63 16 18.00 457 115 2t 10.75 273 39.16 995 9.38 238 9.50 241 .66 17 ... 1.28 33 37.25 946 37.25 946 9.50 241 6.63 168 .63 16 9.50 241 115 2 22.38 568 28.05 712 9.52 242 18.00 457 .77 20 ... 3.83 97 21.19 538 3.03 77 18.00 457 .77 20 ... ... 200 1 24.25 616 37.25 946 13.81 351 19.75 502 1.52 39 ... 30.00 762 ... ... ... ... ... 315 SGO Vertical 6 K SFO Vertical 5 J SEO 8736 4 I SDO Vertical 3 H SGO Vertical 6 G SFO Vertical 5 F SEO 8702 SHO SJO Horizontal Horizontal K E SDO Vertical L M I ... ... ... Vertical type design differs from that shown on the corresponding NEMA size horizontal figure, but dimensions listed apply to that figure. 34 © 1998 Square D All Rights Reserved 5/98 Full Voltage Reversing Contacators and Starters — NEMA Approximate Dimensions – Class 8702, 8736 A H (4) I Dia. Mounting Holes A C B B G RESET E F D C 1.50 H 38 Figure 4 D A E G D FC B G (4) L Dia. Mounting Holes I WX J H K Figure 6 D A E D G Figure 5 NEMA Type 1 Dimensions — Inches/mm C NEMA Class Fig. A B D Size No. No. 8702 8736 IN mm IN mm IN mm IN mm IN Wt (Lbs) E F G mm IN mm IN mm IN H B G (4) J Dia. Mounting Holes 00, 0 j 8702 & 11.88 302 11.88 302 7.41 188 7.53 191 9.75 248 1.06 27 1.06 27 9.75 248 1.06 8736 4 1j 8702 & 2j 14.88 378 14.13 359 7.56 192 7.66 195 12.75 324 1.06 27 1.06 27 12.00 305 1.06 8736 4 3t 8702 & 4 18.16 461 29.16 741 9.25 235 9.25 235 15.50 394 1.33 34 1.33 34 26.50 673 1.33 8736 4t 8702 & 5 35.22 895 46.22 1174 12.81 325 12.93 328 31.00 787 2.11 54 2.11 54 42.00 1067 2.11 8736 4 8702 & 6 36.22 920 62.22 1580 19.47 495 19.47 495 8736 5 Floor Mounting 8702 & 5 7 34.50 876 93.00 2362 23.50 597 23.50 597 8736 j Standard enclosure has space for a fused control transformer, Form F4T, on Sizes 0-2, except for Size 0 & 1 4-Pole. t 3-Pole only. 27 .31 8 16 17 27 .31 8 24 25 34 .44 11 95 98 54 .56 14 298 315 400 405 ... ... NEMA Type 4 & 4X – Stainless Steelq NEMA Class Size Number 0j 1j 2j I 3t 4t H Figure 7 8702 8736 mm IN mm IN mm Dimensions — Inches/mm FC I 5 6 7 j t q Fig. No. A B C D E Weight (Lbs) Hub Dia. F G H I J K L W X Bot. Top & 8702 8736 Only Bot. 12.63 7.81 14.69 2.56 7.50 13.50 .59 3.88 18.41 1.66 2.31 .31 3⁄4 321 198 373 65 191 343 15 99 468 42 59 8 14.88 8.25 15.75 12.56 9.75 15.00 .38 3.88 20.88 1.72 2.63 .31 3⁄4 8702 & 8736 6 378 210 400 319 248 381 10 99 530 44 67 8 18.16 8.75 32.22 3.08 12.00 30.50 .88 3.69 26.72 2.56 3.19 .44 3⁄4 8702 6 461 222 818 78 305 775 22 94 679 65 81 11 18.16 9.56 32.22 3.08 12.00 30.50 .88 4.50 26.72 2.56 3.19 .44 3⁄4 8736 6 461 243 818 78 305 775 22 114 679 65 81 11 35.22 12.13 49.22 4.11 27.00 48.00 .63 4.59 45.81 2.97 3.50 .56 3⁄4 8702 6 895 308 1250 104 686 1219 16 117 1164 75 89 14 35.22 12.94 49.22 4.11 27.00 48.00 .63 5.41 45.81 2.97 3.50 .56 3⁄4 8736 6 895 329 1250 104 686 1219 16 137 1164 75 89 14 36.22 70.13 19.47 8702 & 8736 5 920 1781 495 Floor Mounting 34.50 101.00 23.50 8702 & 8736 5 876 2565 597 Standard enclosure has space for a fused control transformer, Form F4T, on Sizes 0-2, except for Size 0 & 1 4-Pole devices. 3-Pole only. Size 6 & 7 are sheet steel enclosures and are rated NEMA Type 4 only. 8702 & 8736 6 1 25 26 11⁄2 33 35 21⁄2 96 ... 21⁄2 ... 99 31⁄2 300 ... 31⁄2 ... 317 500 505 ... ... NEMA Type 12 Dimensions — Inches/mm NEMA Class Fig. A B C D Size Number No. IN mm IN mm IN mm IN 0j 1j 2j 3t 4t 5 6 7 j t E mm IN F mm IN G H mm IN mm IN I mm IN Wt (Lbs) J 8702 8736 mm IN mm 8702 & 7 11.88 302 7.75 197 13.75 349 2.56 65 6.75 171 12.75 324 .50 13 3.66 93 18.13 461 .31 8736 8702 & 7 14.88 378 7.88 200 16.00 406 2.56 65 9.75 248 15.00 381 .50 13 3.66 93 21.25 540 .31 8736 8702 7 18.16 461 9.25 235 31.50 800 3.08 78 12.00 305 30.50 775 .50 13 3.69 93 26.72 679 .44 8736 7 18.16 461 9.56 243 31.50 800 3.08 78 12.00 305 30.50 775 .50 13 4.50 114 26.72 679 .44 8702 7 35.22 895 13.13 334 49.00 1245 4.13 105 27.00 686 48.00 1219 .50 13 5.31 135 45.88 1165 .56 8736 7 35.22 895 13.94 354 49.00 1245 4.13 105 27.00 686 48.00 1219 .50 13 6.13 156 45.88 1165 .56 8702 & 5 36.22 920 62.22 1580 19.47 495 8736 Floor Mounting 8702 & 5 34.50 876 93.00 2362 23.50 597 8736 Standard enclosure has space for a fused control transformer, Form F4T, on Sizes 0-2, except for Size 0 & 1 4-Pole devices. 3-Pole only. 8 23 24 8 31 32 11 11 14 14 96 ... 302 ... ... 99 ... 319 490 495 ... ... 35 5/98 © 1998 Square D All Rights Reserved Full Voltage Reversing Contactors and Starters — NEMA Approximate Dimensions – Class 8702, 8736 NEMA Type 4X — Watertight and Corrosion Resistant Glass Polyester Enclosure A E NEMA Class Size C F Type A No. of Fig. Poles IN B C mm IN mm IN E F mm IN mm IN mm 0-2 SBW 8702/36 SCW SDW All 16.88 429 9.78 248 22.75 578 10.13 257 21.50 546 0-2 t SBW 8702/36 SCW SDW All 24.63 626 11.94 303 27.00 686 17.88 454 25.75 654 3-4 8702/36 SEW SPW All 25.81 656 11.94 303 33.50 851 18.50 470 32.25 819 3-4 t 8702/36 SEW SPW All 32.00 813 12.13 308 39.31 998 23.88 607 38.13 969 With control power transformer (Form F4T) t B Figure 7 NEMA Type 7 & 9 Bolted Enclosure — Figure 8 Dimensions — Inches/mmc NEMA Size Type IN mm IN mm IN mm IN mm IN mm IN mm IN mm IN mm IN mm 0-2 SBT SCT SDT 14.25 362 27.63 702 9.50 241 12.25 311 19.25 489 9.63 245 11.50 292 2.38 60 3.13 80 115 3-4 t SET SFT 24.50 622 45.63 1159 13.75 349 22.50 572 27.50 699 13.75 349 15.38 391 3.44 87 4.00 102 180 c G H J K L N P Q, R Wt (Lbs) S, T, U, V Dimensions shown for 2 or 3-Pole devices only. V U Space Required To Remove Top Cover O N Circuit Breaker Handle not supplied on Class 8502 or 8536 E Q H 1/2" NPT for Breather and Drain L Rear Seal R N A K (2) "L" Pipe Tap Top and Bottom R S T G G C F L D B Threaded Cover Enclosure J P Mounting for 4 Bolts M J T Mtg. Holes and/or Slots (3) Circuit Breaker Operational Handle – Combination Form Only P (Add 1.00 Inch To Overall Width) Overload Reset Figure 8 H S K Figure 9 Space Required To Remove Bottom Cover NEMA 7 & 9 SPIN TOP ® Enclosure — Figure 9 Dimensions — Inches/mm NEMA Type Size A Bt Bj Ct Cj D Et Ej 0-1 SBR SCR 12.00 41.06 46.13 68.06 79.13 16.75 7.25 305 1043 1172 1729 2010 425 184 2 SDR 16.13 48.50 50.50 81.50 85.00 20.25 12.13 9.13 410 1232 1283 2070 2159 514 308 232 3 SER Consult Local Square D Field Office t j F 12.25 7.69 311 195 8.63 219 Gt Gj Ht Hj Jt Jj K 26.13 26.13 3.00 664 664 76 9.00 229 24.00 24.00 8.50 610 610 216 27.75 32.75 8.00 705 832 203 4.50 114 M N P R 2.06 52 9.38 238 5.25 133 1.50 38 .38 10 70 25.00 30.00 12.00 12.63 11.00 5.50 635 762 305 321 279 140 2.50 64 .38 10 100 Without control transformer. With control transformer (Form F4T). 36 © 1998 Square D All Rights Reserved Wt (Lbs) L 5/98 Full Voltage Contactors — NEMA Application Data, Selection – Class 8702 Auxiliary Contact Units Class 8702 Type WF Reversing Vacuum Contactor Additional auxiliary contact units may be added to the Size 4 and 5 reversing contactors in the field. A maximum of 2 units may be added to the Size 4; a maximum of 1 unit may be added to the Size 5. No additional units may be added to the Size 6, however, 1 N.O. and 1 N.C. circuit are available on each forward and reverse contactor for customer use. GENERAL INFORMATION Class 8702 Type W reversing vacuum contactors are a new addition to the Square D line of contactors. These reversing contactors are used to switch capacitors, transformers and electric motors where overload protection is separately provided. Type W reversing vacuum contactors are designed for operation at 600 Volts, 50/60 Hertz. By design, these contactors are well suited to heavy-duty applications in harsh environments. The power contacts are sealed in ceramic tubes, called vacuum interrupters or vacuum bottles, where the air has been evacuated. Arc quenchers are not required because any arc formed between opening contacts is not sustained due to the presence of the vacuum. The arc is extinguished when the current crosses zero after the contacts are opened, therefore the arc typically does not survive more than one half cycle. There is one vacuum interrupter or bottle per pole, therefore a three pole contactor has three vacuum interrupters or bottles. The power contacts are not affected by ambient conditions or contamination. This provides for long life and reliable operation in harsh applications. Altitude The reversing vacuum contactor is designed to tolerate normal barometric pressure variances up to 6600 feet above sea level. If the contactor is to be used above 6600 feet above sea level, please consult the factory. Termination Means The Size 4 reversing vacuum contactor is supplied with line and load side lugs. The Size 5 and 6 reversing vacuum contactors are supplied without line and load side lugs. Class 9999 Type LUW5 and LUW6 lug kits are available for the Size 5 and 6 contactors. These kits include six lugs and the necessary mounting hardware. Auxiliary Contacts An auxiliary contact block, Class 9999 Type WX11, with one normally-open contact and normally-closed contact is used with Size 4, 5 and 6 vacuum contactors. Class 8702 – Full Voltage Reversing Vacuum Contactors (Horizontal Only) 3-Pole Polyphase – 600 Volts AC Maximum (50-60 Hertz) NEMA Size 4 5 6 Enclosed Ampere Rating 135 270 540 Locked Rotor Motor Volts Current (Amps) Open Type Max. HP t Coil Voltage 1080 200 230 380 460 575 40 50 75 100 100 120 240 120 480 600 WFO3V02S WFO3V03 WFO3V02S WFO3V06 WFO3V07 2160 200 230 380 460 575 75 100 150 200 200 120 240 120 480 600 WGO3V02S WGO3V03 WGO3V02S WGO3V06 WGO3V07 4320 200 230 380 460 575 150 200 300 400 400 120 240 120 480 600 WHO3V02S WHO3V03 WHO3V02S WHO3V06 WHO3V07 Type File E78351 CCN NLDX2 File LR60905 Class 3211-04 37 5/98 © 1998 Square D All Rights Reserved Full Voltage Contactors — NEMA Selection – Class 8702 Class 9998 – Replacement Coils for Class 8502 and 8702 Vacuum Contactors Size Type 4 5 6 Poles WF WG WH Hertz Suffix Number (Complete Coil Number Consists of Class and Type Followed by Suffix Number) 50 60 120 Volts 110 Volts 240 Volts 220 Volts 480 Volts 440 Volts 600 Volts 550 Volts 120 240 480 600 Class & Type 9998WF 9998WG 9998WH All Class 9999 – Vacuum Contactor Kits For Use With Kit Description Class 9999 Type Auxiliary Contacts, Non-Convertible 1-N.O. & 1-N.C. Isolated Contacts 9999WX11 Type Size WF-WH 4-6 WF WG-WH 4 5-6 Coil Circuit Auxiliary Contacts 1-N.O. & 1-N.C. Isolated Contacts, Delayed Break 1-N.C. Isolated Contact 9999WCX11 9999WLX01 WG WH 5 6 Lug Kits (6) lugs included (6) lugs included 9999LUW5 9999LUW6 Auxiliary Contact Ratings — NEMA A600, R300 .44 4.88 .28 Dia. 3.50 11 7 (3) Mtg. Holes 89 Description Voltage Make Break Class 9999 Type WX11 and WXO1 120-600 Vac 72-120 Vac 28-72 Vac 28-300 Vac 7200 VA 60 A 60 A 28 A 720 VA 720 VA 10 A 28 VA Mechanical Overtravel Interlock Gauge 124 8.80 6.00 7.00 175 37 Rear View Drilling Plan 6.45 1.13 1.44 178 Recess for Auxiliary Contact 107 6.88 224 Max. 152 4.20 164 29 9.75 Side View 248 Front View Class 8702 WF 22.00 559 5.81 148 .60 4.00 2.50 3.65 102 64 93 51 2.70 .86 112 165 3.40 3.90 70 45 1 2 3 4 5 6 14.00 .38 356 10 417 127 457 14.00 1.50 38 Name Plate 95 16.40 5.00 18.00 0 1 2 38 3.75 99 86 7 8 9 1.50 6.50 175 2.75 1.76 2.70 69 69 6.90 22 15 4.40 2.00 7.75 2.48 3.98 197 63 24.00 610 108 .40 64 10 3.75 2.70 9.56 69 243 559 1.89 2.70 4.40 112 22.00 48 24.00 69 1.40 2.00 51 7.75 197 36 610 Size 6 Reversing Contactor Outline without Lugs Size 5 Reversing Contactor Outline without Lugs Class 8702 WG 457 95 101 4.26 2.50 18.00 356 Name Plate Class 8702 WH 38 © 1998 Square D All Rights Reserved 5/98 Contents SECTION 3 – MOTOR STARTERS MULTI-SPEED Application Data – Class 8810, 8811, 8812 . . . . . . . . . . . . . . . . . . . . . 40-41 Line Voltage — with Melting Alloy Overload Relays – Class 8810. . . . . . . 42 Reversing Line Voltage Type — with Melting Alloy Overload Relays – Class 8810 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Line Voltage — with Melting Alloy Overload Relays or Solid State Overload Relays – Class 8810. . . . . . . . . . . . . . . . . . . 44-45 Line Voltage — with Melting Alloy Overload Relays – Class 8811, 8812. . 48 Application Data – Class 8810, 8811, 8812 . . . . . . . . . . . . . . . . . . . . . . . . 47 Application Data for Types SB-SJ – Class 8810, 8811, 8812 . . . . . . . . . . 48 Dimensions – Class 8810, 8811, 8812 . . . . . . . . . . . . . . . . . . . . . . . . . . . 49 Application Data – Class 8810, 8811, 8812 . . . . . . . . . . . . . . . . . . . . . 50-51 Disconnect Switch or Circuit Breaker Type – Class 8810, 8811, 8812 . . . 52 39 5/98 © 1998 Square D All Rights Reserved AC Multispeed Magnetic Starters Application Data – Class 8810, 8811, 8812 Typical Schematic Diagrams High 4 Low 5 H 1 Stop Multispeed motors are available in two basic versions: L OL OL L High 3 L 2 H H L1 L2 L3 L L L H OL OL OL H L T1 T2 H OL OL T3 OL Separate winding motors are usually chosen when flexibility is important, since the speeds of a consequent pole motor are usually limited to a 2/1 ratio; a broad range of speeds can be obtained on a separate winding motor. L T6 T4 T5 Both consequent pole and separate winding motors are available in three types: A30064-446 2-Speed Consequent Pole Constant Horsepower NEMA Size 0-4 Sizes 5, 6 & 7 Use Special Circuitry High 4 Low 5 H 1 Stop L OL OL L High 3 L 2 • Consequent pole • Separate winding A separate winding motor has a winding for each speed while a consequent pole motor has a winding for every two speeds (three speed motors have two windings). The motor connections (and thus the types of controllers) for two speed starters are exemplified by the schematic diagrams shown to the left. Note that consequent pole two speed controllers involve a 5-pole and a 3-pole starter while separate winding controllers have two 3-pole starters. • Constant horsepower • Constant torque • Variable torque Typical applications for these different types of motors are shown below. NOTE: For detailed information involving the technical aspects of flexibility of the starters used in the multispeed controllers, see Classes 8702, 8736 and 8810 application data. H H L1 L2 L3 Typical Applications L L H L OL OL OL H T1 H H OL OL OL Constant H.P. H T2 T3 T6 T4 • Spindles • Cutting Tools T5 — Lathes — Saws 2-Speed Consequent Pole Constant or Variable Torque NEMA Size 0-4 Sizes 5, 6 & 7 Use Special Circuitry High 4 1 Stop Low 5 H L High 3 L H OL OL • • • • L 2 H L1 L2 L3 L L L H OL OL OL T1 T2 T3 H OL OL Constant Torque H Conveyors Mills Dough Mixers Reciprocating Pumps Variable Torque OL T11 T12 T13 • • Fans Centrifugal Pumps A30064-442 2-Speed Separate Winding Constant HP, Constant Torque and Variable Torque NEMA Size 0-4 Sizes 5, 6 & 7 Use Special Circuitry Speed Selection The speed of a squirrel cage motor is directly proportional to the power supply frequency and inversely proportional to the number of poles in the stator winding. With the frequency constant, motor speed is determined by the number of poles. (120) (Frequency) (RPM) Speed = No. of Poles Horsepower = T x S Where: T = Torque in Lb Ft 5250 S = Speed in RPM 40 © 1998 Square D All Rights Reserved 5/98 AC Multispeed Magnetic Starters Application Data – Class 8810, 8811, 8812 ADDITIONAL FEATURES Special Pilot Lighting High 4 Low 5 H 1 Stop L OL OL L 2 L High 3 L H H General On Standard starters are not equipped with any special relays to require starting at lowest speed, progressive acceleration or deceleration through each speed, etc. However, when the type of motor or characteristics of the load involved make certain starting or control sequences necessary, four types of relays/timers are available to accomplish the required function. H To Power Circuit A30080-017 One pilot light “ON” High 4 1 Stop Low 5 H L High 3 L H OLOL Form R1 Compelling Relay L 2 This relay makes it necessary for the motor to be started at low speed before any higher speed can be selected. Pressing any push button except the low speed will not start the motor. This arrangement insures that the motor will always start the load at low speed. The stop button must be pressed before it is possible to change from a higher to a lower speed. H L Special Relays for Non-Reversing and Reversing Multispeed Starters Off H To Power Circuit A30080-018 One pilot light “OFF” Form R2 Accelerating Relay/Timer L High 4 1 Stop 2 Low 5 H L L H High 3 L H OLOL H To Power Circuit When the starter is equipped with Form R2 accelerating relays, the ultimate speed is determined by the button which is pressed, but the starter will start the motor at low speed and then automatically accelerate it through successive steps until the selected speed is reached. Definite time intervals must elapse between each speed change. Individual timing relays are provided for each interval, and all are adjustable. The stop button must be pressed before it is possible to change from a higher to a lower speed. A30080-015 Two pilot lights “L” and “H” High 4 1 Stop Low Form R3 Decelerating Relay/Timer 5 H L High 3 L H OLOL L 2 L H H L On Off H This is similar in action to Form R2 accelerating relays, except that they function to prevent immediate transfer from a higher to a lower speed. A definite time interval, preset on the timer, must elapse between each speed change. Form R10 Antiplugging Relays/Timers To Power Circuit A30080-016 Two pilot lights “ON” and “OFF” L 1 Stop High 4 2 Low 5 H L L H High 3 L H OLOL If it is necessary to have an imposed time delay when transferring from the forward to the reverse direction or reverse to forward, then Form R10 should be included in the form designation of the reversing multispeed starters. This provides up to a 60 second delay in the transfer of the direction of the motor, and can help prevent damage which could result from plugging. H L H Off To Power Circuit A30080-019 Three pilot lights “L”, “H” and “OFF” 41 5/98 © 1998 Square D All Rights Reserved AC Two Speed Magnetic Starters Line Voltage — with Melting Alloy Overload Relays – Class 8810 Line voltage type, ac two speed starters are designed to control reconnectable squirrel cage motors to operate at two different constant speeds, depending upon their construction. The use of an automatic starter and proper control station permits greater operating efficiency and offers protection to both motor and machine against improper sequencing or too rapid speed change. Protection against motor overload in each speed is provided by an overload relay block which accepts three (3) thermal units. Class 8810 Non-reversing – Two Speed – 50-60 Hertz – 600 Volts Maximum Class 8810, Type S in NEMA Type 1 Enclosure Maximum Polyphase Horsepower Ratings Type of Motor General Purpose Constant Torque Enclosure or Variable NEMA Torque Motors Type 1 Constant NEMA Horsepower Size Motors 200 V 230 V 460460Type 200 V 230 V 575 V 575 V Watertight and Dusttight Enclosure (Stainless Steel) (Sizes 0-5 only) Size 6 Sheet Steelc NEMA Type 4 For Hazardous Locations Class I Groups C & D Class II Groups E, F & G NEMA Types 7 and 9 k Dusttight and Driptight Open Industrial Use Type Enclosure NEMA Type 12j Type Type Type Type Single Winding (Consequent Pole) 5-Pole – 3-Pole 0 2 2 3 ... ... ... SBG-1 SBW-1q ... SBA-1q SBO-1 ... ... ... SCG-1 SCW-1q SCR-1k SCA-1q SCO-1 1 5 5 71⁄2 71⁄2 10 20 ... ... ... SDG-1 SDW-1 SDR-1k SDA-1 SDO-1 Constant 2 3 20 25 40 ... ... ... SEG-1 SEW-1 SER-1k SEA-1 SEO-1 HP 4 30 40 75 ... ... ... SFG-1 SFW-1 ... SFA-1 SFO-1 5 60 75 150 ... ... ... SGG-1 SGW-1 ... SGA-1 SGO-1 6 100 150 300 ... ... ... SHG-1 SHW-1 ... SHA-1 SHO-1 0 ... ... ... 3 3 5 SBG-2 SBW-2q ... SBA-2q SBO-2 Constant 1 71⁄2 10 SCG-2 SCW-2q SCR-2k SCA-2q SCO-2 ... ... ... 71⁄2 Torque 2 ... ... ... 10 15 25 SDG-2 SDW-2 SDR-2k SDA-2 SDO-2 or 3 ... ... ... 25 30 50 SEG-2 SEW-2 SER-2k SEA-2 SEO-2 ... ... ... 40 50 100 SFG-2 SFW-2 ... SFA-2 SFO-2 Variable 4 5 . . . . . . . . . 75 100 200 SGG-2 SGW-2 . . . SGA-2 SGO-2 Torque 6 ... ... ... 150 200 400 SHG-2 SHW-2 ... SHA-2 SHO-2 Two Winding (Separate WInding) 3-Pole – 3-Pole f 0 2 2 3 ... ... ... SBG-3 SBW-3q ... SBA-3q SBO-3 ... ... ... SCG-3 SCW-3q SCR-3k SCA-3q SCO-3 1 5 5 71⁄2 10 20 ... ... ... SDG-3 SDW-3 SDR-3k SDA-3 SDO-3 2 71⁄2 Constant 3 20 25 40 ... ... ... SEG-3 SEW-3 SER-3k SEA-3 SEO-3 4 30 40 75 ... ... ... SFG-3 SFW-3 ... SFA-3 SFO-3 HP f 5 60 75 150 ... ... ... SGG-3 SGW-3 ... SGA-3 SGO-3 6 100 150 300 ... ... ... SHG-3 SHW-3 ... SHA-3 SHO-3 7 ... 225 450 ... ... ... SJG-3 ... ... SJA-3 SJO-3 0 ... ... ... 3 3 5 SBG-4 SBW-4q ... SBA-4q SBO-4 71⁄2 10 SCG-4 SCW-4q SCR-4k SCA-4q SCO-4 ... ... ... 71⁄2 Constant 1 2 . . . . . . . . . 10 15 25 SDG-4 SDW-4 SDR-4k SDA-4 SDO-4 Torque 3 ... ... ... 25 30 50 SEG-4 SEW-4 SER-4k SEA-4 SEO-4 or 4 ... ... ... 40 50 100 SFG-4 SFW-4 ... SFA-4 SFO-4 Variable 5 ... ... ... 75 100 200 SGG-4 SGW-4 ... SGA-4 SGO-4 Torque f 6 ... ... ... 150 200 400 SHG-4 SHW-4 ... SHA-4 SHO-4 7 ... ... ... ... 300 600 SJG-4 ... ... SJA-4 SJO-4 f Type numbers shown for three phase separate winding motor starters apply only when motor windings are wye connected. When motor windings are connected open delta use three phase consequent pole motor starters. q Separate NEMA Type 4 and 12 enclosures available. j NEMA Type 12 enclosures may be field modified for outdoor applications. c NEMA Type 4X enclosures available; consult local Square D field office. k Addition of forms to standard NEMA Type 7 and 9 enclosed devices is limited. Consult local Square D field office. 380 Volts, 50 Hertz – above type numbers will apply to starters for 380 volt, 50 hertz but the selection by NEMA size must be based on the horsepower ratings in the following table: NEMA Size 0 1 2 3 4 5 6 Constant Horsepower 3 71⁄2 20 40 60 100 200 Constant or Variable Torque Horsepower 5 10 25 50 75 150 300 Thermal Units File E78351 CCN NLDX File LR60905 Class 3211-04 Thermal units should be ordered separately. See Thermal Unit Selection Index. Do not use horsepower rating(s) for thermal unit selection. All three phase two speed magnetic starters require six (6) thermal units, three per speed. Use nameplate FLC’s (Full Load Currents) from motor nameplate. Special Features — See Factory Modifications and Forms, Catalog 9999CT9701. Dimensions — See Pages 49-52. Field Modification Kits — See Catalog 9999CT9701 Section. Class 8810, 8811 and 8812 multispeed starters, both non-reversing and reversing versions, are available with either circuit breaker or disconnect switch. Refer to Factory Modifications and Forms for Form numbers and price additions. How to Order: To Order Specify: • Class Number • Type Number • Coil Voltage Code • Form(s) Catalog Number Class Type Coil Voltage Code Form(s) 8810 SCO8 VO6 P1S 42 © 1998 Square D All Rights Reserved 5/98 AC Reversing Two Speed Magnetic Starters Line Voltage Type — with Melting Alloy Overload Relays – Class 8810 Class 8810 AC reversing two speed starters combine the functions of reversing and speed selection in one controller. The units are electrically and mechanically interlocked, and include motor running overcurrent protection. Typical applications include conveyors, drilling and tapping machines, and cooling tower fans. Many of these applications also require the special relay features. Class 8810 – Reversing – 50-60 Hertz – 600 Volts Maximum Maximum Polyphase Ratings Type of Motor Reversing In One Speed Only Dusttight and General Driptight Industrial Constant Constant Torque Open Purpose NEMA Use Enclosure Horsepower or Variable Type Enclosure Size NEMA Type 12 Motors Torque Motors NEMA Type 1 (Type 3 and 3R)f 200 V 230 V 460-575 V 200 V 230 V 460-575 V Typea Typea Typea Reversing In Both Speeds Dusttight and General Driptight Industrial Open Purpose Use Enclosure Type Enclosure NEMA Type 12 NEMA Type 1 (Type 3 and 3R)f Type Type Type Single Winding Constant Horsepower 0 1 2 3 4 5 2 5 71⁄2 20 30 60 2 5 10 25 40 75 3 71⁄2 20 40 75 150 ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... SBG-21 SCG-21 SDG-21 SEG-21 SFG-21 SGG-21 SBA-21 SCA-21 SDA-21 SEA-21 SFA-21 SGA-21 SBO-21 SCO-21 SDO-21 SEO-21 SFO-21 SGO-21 SBG-31 SCG-31 SDG-31 SEG-31 SFG-31 SGG-31 SBA-31 SCA-31 SDA-31 SEA-31 SFA-31 SGA-31 SBO-31 SCO-31 SDO-31 SEO-31 SFO-31 SGO-31 Single Winding Constant Torque or Variable Torque 0 1 2 3 4 5 ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... 3 71⁄2 10 25 40 75 3 71⁄2 15 30 50 100 5 10 25 50 100 200 SBG-22 SCG-22 SDG-22 SEG-22 SFG-22 SGG-22 SBA-22 SCA-22 SDA-22 SEA-22 SFA-22 SGA-22 SBO-22 SCO-22 SDO-22 SEO-22 SFO-22 SGO-22 SBG-32 SCG-32 SDG-32 SEG-32 SFG-32 SGG-32 SBA-32 SCA-32 SDA-32 SEA-32 SFA-32 SGA-32 SBO-32 SCO-32 SDO-32 SEO-32 SFO-32 SGO-32 Constantj Horsepower 0 1 2 3 4 5 2 5 71⁄2 20 30 60 2 5 10 25 40 75 3 71⁄2 20 40 75 150 ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... SBG-23 SCG-23 SDG-23 SEG-23 SFG-23 SGG-23 SBA-23 SCA-23 SDA-23 SEA-23 SFA-23 SGA-23 SBO-23 SCO-23 SDO-23 SEO-23 SFO-23 SGO-23 SBG-33 SCG-33 SDG-33 SEG-33 SFG-33 SGG-33 SBA-33 SCA-33 SDA-33 SEA-33 SFA-33 SGA-33 SBO-33 SCO-33 SDO-33 SEO-33 SFO-33 SGO-33 Constantj Torque or Variable Torque 0 1 2 3 4 5 ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... ... 3 71⁄2 10 25 40 75 3 71⁄2 15 30 50 100 5 10 25 50 100 200 SBG-24 SCG-24 SDG-24 SEG-24 SFG-24 SGG-24 SBA-24 SCA-24 SDA-24 SEA-24 SFA-24 SGA-24 SBO-24 SCO-24 SDO-24 SEO-24 SFO-24 SGO-24 SBG-34 SCG-34 SDG-34 SEG-34 SFG-34 SGG-34 SBA-34 SCA-34 SDA-34 SEA-34 SFA-34 SGA-34 SBO-34 SCO-34 SDO-34 SEO-34 SFO-34 SGO-34 j q f Prices and Type numbers shown for three phase, separate winding motor starters apply only when motor windings are wye connected. When motor windings are connected open delta use the prices shown for consequent pole motor starters. Specify the speed which requires reversing by adding an L (low) or an H (high) after the type number, e.g. A Class 8810 Type SBG-21 with reversing in low only would be ordered as a Class 8810 Type SBG-21L. NEMA Type 12 enclosures may be field modified for outdoor applications. For details refer to Class 9991. Typical Elementray Diagrams 5 2 3 4 3 2 High L1 1 L3 L2 High 4 Low 5 L 1 Stop 5 4 High Low High 3 2 Low H L L H OL H Stop 1 L1 3 Wire Control COM OL L2 L3 Alarm (If supplied) T12 T1 T3 T11 T13 T2 T11 1.2 or 3 OLR Contacts Motor T12 Speed Low High T13 T2 L1 L2 L3 Open T1 T2 T3 T11, T12, T13 T11 T12 T13 T1, T2, T3 How to Order: L L T3 1.2 or 3 OLR Contacts T1 T2 T3 H H OL OL H OL T11 T12 T13 Thermal Units To Order Specify: • Class Number • Type Number • Coil Voltage Code • Form(s) T1 L OL OL OL OL COM Catalog Number Class Type Coil Voltage Code Form(s) 8810 SCO8 VO6 P1S Thermal units should be ordered separately. See Thermal Unit Selection Index. Do not use horsepower rating(s) for thermal unit selection. All three phase two speed magnetic starters require six (6) thermal units, three per speed. Use nameplate FLC’s (Full Load Currents) from motor nameplate. 43 5/98 © 1998 Square D All Rights Reserved AC Two Speed Magnetic Starters Line Voltage — with Melting Alloy Overload Relays or Solid State Overload Relays – Class 8810 Class 8810 — Non-Reversing — Horizontally Arranged Starters q j Glass Polyester Watertight, Dusttight and Corrosion Resistant Enclosure 50-60 Hertz – 600 Volts Maximum For Consequent Pole Motors Maximum Horsepower Ratings For Separate Winding Motors Type of Motor NEMA Size 200 V 230 V 380 V 460-575 V Type Type Constant Horsepower 0 1 2 3 4 2 5 71⁄2 20 30 2 5 10 25 40 3 71⁄2 20 40 60 3 71⁄2 20 40 75 SBW-51 SCW-51 SDW-51 SEW-51 ... SBW-53 SCW-53 SDW-53 SEW-53 SFW-53 Constant Torque or Variable Torque 0 1 2 3 4 3 71⁄2 10 25 40 3 71⁄2 15 30 50 5 10 25 50 75 5 10 25 50 100 SBW-52 SCW-52 SDW-52 SEW-52 ... SBW-54 SCW-54 SDW-54 SEW-54 SFW-54 q j NEMA Type 4X hubs are included with each starter at no additional cost. Combination features available – consult factory. Vertically Arranged, Open Type, Two Speed Starters Vertically arranged starters are used where width limitations prevent the use of the conventional horizontally arranged device. Such starters may be used to advantage in threaded NEMA Type 7 explosion-proof enclosures, and in multi-motor panels in which other equipment within the enclosure used limits the available width. These starters have all the features of the standard horizontally arranged devices, but the two contactors are in a vertical arrangement. These starters are offered in open type construction only. Class 8810 — Non-Reversing — Vertically Arranged Starters – 50 or 60 Hertz – 600 Volts Maximum For Consequent Pole Motors Maximum Horsepower Ratings For Separate Winding Motors Type of Motor NEMA Size 200 V 230 V 380 V 460-575 V Type Type Constant Horsepower 0 1 2 3 4 2 5 71⁄2 20 30 2 5 10 25 40 3 71⁄2 20 40 60 3 71⁄2 20 40 75 SBO-11 SCO-11 SDO-11 SEO-11 SFO-11 SBO-13 SCO-13 SDO-13 SEO-13 SFO-13 Constant Torque or Variable Torque 0 1 2 3 4 3 71⁄2 10 25 40 3 71⁄2 15 30 50 5 10 25 50 75 5 10 25 50 100 SBO-12 SCO-12 SDO-12 SEO-12 SFO-12 SBO-14 SCO-14 SDO-14 SEO-14 SFO-14 How to Order: To Order Specify: • Class Number • Type Number • Coil Voltage Code • Form(s) Catalog Number Class Type Coil Voltage Code Form(s) 8810 SCO8 VO6 P1S Thermal Units Thermal units should be ordered separately. For selection of thermal units, refer to the Catalog Thermal Unit Selection Index, Digest or Bulletin SM-416, entitled “Application and Selection of Overload Relays.” Do not use horsepower rating(s) for thermal unit selection. All three phase two speed magnetic starters require six (6) thermal units, three per speed. Use nameplate FLC’s (Full Load Currents) from motor nameplate. 44 © 1998 Square D All Rights Reserved 5/98 AC Two Speed Magnetic Starters Line Voltage — with Melting Alloy Overload Relays or Solid State Overload Relays – Class 8810 Special Arrangements with Three Devices Three Type S Contactors can be mechanically interlocked so that only one contactor can be energized at any one time. The mechanical interlock, pictured in Figure 2, is an interference (non-jamming) type locking at the beginning of the stroke of any contactor. Factory assembled units are listed in the table below. Figures 1 and 2 show factory assembled and wired devices. All contactors are both electrically and mechanically interlocked. The class and type numbers listed only cover the contactor and/or starter mounting arrangement, NEMA size of the devices, and the number of poles. A power and control wiring diagram must accompany each order. Additional electrical interlocks are available factory (or field) installed in the locations shown in Figure No. 2 and Table No. 2, Page 52. 8810 starters are supplied with melting alloy type thermal overload relays. For customer assembled units, the basic A C E G J L No. No. No. mechanical interlock and base assembly can be OL-35 1 2 3 purchased separately. Standard Class 8502 Cont. Cont. Cont. B D F H K M contactors and Class 8536 starters are used in the locations and pole arrangement shown. If Class 8536 starters are used, it is necessary to OL-1 OL-2 OL-3 mount a Class 9999 Type SO bracket below the overload block to give the block support. Figure 2 For electrically interlocking customer assembled Contactor, overload and external electrical units a Class 9999 Type SX-12, normally closed interlock positions internal interlock and/or a Class 9999 Type SX-7, normally closed external interlock can be used. Three Mechanically Interlocked Contactors and Starters — Factory Assembled Class Type 8810 8810 SCO-41 SCO-42 SCO-43 SCO-44 SDO-41 SDO-42 SCO-45 SCO-46 SCO-47 SCO-48 SDO-43 SDO-44 Contactor Position — See Figure 2 No. 1 Contactor No. 2 Contactor Size and Poles Size and Poles NEMA Size 1 NEMA Size 2 NEMA Size 1 NEMA Size 2 No. of Poles No. of Poles No. of Poles No. of Poles Overload No. 3 Contactor Relay Size and Poles Position NEMA Size 1 NEMA Size 2 See Fig. 3 No. of Poles No. of Poles 3 4 ... ... ... ... 3 4 ... ... ... ... 3 3 3 3 ... ... 5 5 5 5 ... ... ... ... 3 4 3 4 ... ... 3 4 3 4 3 3 3 3 ... ... 3 3 3 3 ... ... ... ... ... ... 3 3 ... ... ... ... 3 3 Ordering Information Required 1. Order complete factory assembled devices by class and type number from table above. 2. Supply wiring diagram for power and control connections as catalog number only covers general contactor and starter mounting arrangement. 3. Voltage and frequency of contactor coils. 4. Select additional factory assembled electrical interlocks from table on Page 47 specifying interlock position letter and whether interlock is N.O. or N.C. 5. Example of ordering information required on factory assembled devices: (a) Class 8810 Type SCO-45 ... ... ... ... 3 3 ... ... ... ... 5 5 Number of Thermal Units Required OL-2 & -3 6 OL-2 & -3 6 (b) Wired per diagram (which must accompany order) (c) All coils — 120 volts, 60 hertz (d) Additional electrical interlocks: C — N.O., E — N.C., and J — N.O. 6. For customer assembly of three mechanically interlocked devices, order the mechanical interlock and overload relay mounting brackets by class and type numbers. Thermal Units Thermal units should be ordered separately. For selection of thermal units, refer to the Catalog Thermal Unit Selection Index R Digest. Use the motor nameplate FLC’s (Full Load Currents) to select thermal units. 45 5/98 © 1998 Square D All Rights Reserved Three and Four Speed AC Magnetic Starters Line Voltage — with Melting Alloy Overload Relays – Class 8811, 8812 Class 881 and 8812 line voltage starters are designed to control 3 and 4 speed motors, respectively. The use of an automatic starter and proper control station permits greater efficiency. The addition of compelling relays to a starter gives protection to both the motor and the machine against an improper sequence or a too rapid change in speed. The motor is protected against excessive operating currents by overload relay blocks (one for each motor speed) each of which accepts three (3) thermal units. While the starters listed are for use with consequent pole motors only, separate winding motor starters are also available upon request. Class 8811 — Three Speed AC Magnetic Starters — Consequent Pole, 2 Winding 600 Volts Maximum — 50-60 Hertz Type of Motor 200 V 230 V 460-575 V Type Watertight and Dusttight Enclosure (Stainless Steel) NEMA Type 4 Type Dusttight and Driptight Industrial Use Enclosure NEMA Type 12 (Type 3 and 3R)j Type 2 5 71⁄2 20 30 3 71⁄2 10 25 40 3 71⁄2 10 25 40 SBW-1 SCW-1 SDW-1 SEW-1 SFW-1 SBW-2 SCW-2 SDW-2 SEW-2 SFW-2 SBW-3 SCW-3 SDW-3 SEW-3 SFW-3 SBA-1 SCA-1 SDA-1 SEA-1 SFA-1 SBA-2 SCA-2 SDA-2 SEA-2 SFA-2 SBA-3 SCA-3 SDA-3 SEA-3 SFA-3 General Purpose NEMA Maximum Horsepower Enclosure NEMA Type 1 Size 0 1 Constant 2 Horsepower 3 4 0 1 Constant 2 Torque 3 4 0 1 Variable 2 Torque 3 4 2 5 10 25 40 3 71⁄2 15 30 50 3 71⁄2 15 30 50 3 71⁄2 20 40 75 5 10 25 50 100 5 10 25 50 100 SBG-1 SCG-1 SDG-1 SEG-1 SFG-1 SBG-2 SCG-2 SDG-2 SEG-2 SFG-2 SBG-3 SCG-3 SDG-3 SEG-3 SFG-3 Open Type Type SBO-1 SCO-1 SDO-1 SEO-1 SFO-1 SBO-2 SCO-2 SDO-2 SEO-2 SFO-2 SBO-3 SCO-3 SDO-3 SEO-3 SFO-3 Class 8812 — Four Speed AC Magnetic Starters — Consequent Pole, 2 Winding 600 Volts Maximum — 50-60 Hertz Type of Motor General Purpose NEMA Maximum Horsepower Enclosure NEMA Type 1 Size 200 V 230 V 460-575 V Type Watertight and Dusttight Enclosure (Stainless Steel) NEMA Type 4 Type 0 2 2 3 SBG-1 SBW-1 SCG-1 SCW-1 1 5 5 71⁄2 Constant 2 71⁄2 10 20 SDG-1 SDW-1 Horsepower 3 20 25 40 SEG-1 SEW-1 4 30 40 75 SFG-1 SFW-1 0 3 3 5 SBG-2 SBW-2 1 1 7 ⁄2 10 SCG-2 SCW-2 1 7 ⁄2 Constant 2 10 15 25 SDG-2 SDW-2 Torque 3 25 30 50 SEG-2 SEW-2 4 40 50 100 SFG-2 SFW-2 0 3 3 5 SBG-3 SBW-3 71⁄2 10 SCG-3 SCW-3 1 71⁄2 Variable 2 10 15 25 SDG-3 SDW-3 Torque 3 25 30 50 SEG-3 SEW-3 4 40 50 100 SFG-3 SFW-3 j NEMA Type 12 enclosures may be field modified for outdoor applications. Dusttight and Driptight Industrial Use Enclosure NEMA Type 12 (Type 3 and 3R)j Type SBA-1 SCA-1 SDA-1 SEA-1 SFA-1 SBA-2 SCA-2 SDA-2 SEA-2 SFA-2 SBA-3 SCA-3 SDA-3 SEA-3 SFA-3 Open Type Type SBO-1 SCO-1 SDO-1 SEO-1 SFO-1 SBO-2 SCO-2 SDO-2 SEO-2 SFO-2 SBO-3 SCO-3 SDO-3 SEO-3 SFO-3 Thermal Units Thermal units should be ordered separately. For selection of thermal units, refer to the Catalog Thermal Unit Selection Index R Digest. All starters require the use of three (3) thermal units for each speed of the motor. Do not use the horsepower rating(s) for selection. Use nameplate FLC’s (Full Load Currents) from motor nameplate. How to Order: To Order Specify: File E78351 CCN NLDX • Class Number • Type Number • Coil Voltage Code • Form(s) Catalog Number Class Type Coil Voltage Code Form(s) 8810 SCO8 VO6 P1S File LR60905 Class 3211-04 46 © 1998 Square D All Rights Reserved 5/98 AC Multispeed Magnetic Starters Application Data – Class 8810, 8811, 8812 Application Data for Types SB-SH Form Designations for Factory Installation of Electrical Interlocks Additional Electrical Interlocks on High Starter Standard (No Additional Interlocks) Additional Electrical Interlocks on Low Starter Standard (No Additional Interlocks) Change N.O. Holding Circuit Interlock to N.C. 1 N.O. 1 N.C. 2 N.O. 1 N.O.-1 N.C. 2 N.C. X01 X02 X03 X05 X06 X07 Change N.O. Holding Circuit Interlock to N.C. X10 X11 X12 X13 X15 X16 X17 1 N.O. X20 X21 X22 X23 X25 X26 X27 1 N.C. X30 X31 X32 X33 X35 X36 X37 2 N.O. X50 X51 X52 X53 X55 X56 X57 1 N.O.-1 N.C. X60 X61 X62 X63 X65 X66 X67 2 N.C. X70 X71 X72 X73 X75 X76 X77 Control Transformer Selection Maximum Number of Auxiliary Units The following table gives the proper size control transformer to be used with a given reversing device, with or without additional electrical interlocks or timer. NEMA Size (Type) NEMA Size Type 0, 1 & 2 SB, SC & SD 3 No. of Poles Transformert Class 9070 Type Any EO-2 or GO-2 3 EO-3 or GO-3 4&5 EO-4 SE 4 SF Any EO-4 5 SG Any q 6 SH Any u 7 SJ Any j t q u j Maximum number of auxiliary units No. of on each contactor, forward or Poles of reverse, (in addition to internal Basic holding circuit and electrical Contactor interlocks). 00, 0, 1 2 or 3 and 2 (SA, SB, SC and SD) 4 4 single circuit external interlocks (N.O. or N.C.) 1 single circuit external interlock (N.O. or N.C.) plus 1 attached timer (ON or OFF delay). 2 single circuit external interlocks (N.O. or N.C.) 3, 4, 5 and 6 (SE, SF, SG Any and SH) 2 single circuit external interlocks (N.O. or N.C.) 7 (SJ) Consult local Square D field office Any 1 single circuit external interlock plus 1 attached timer (ON or OFF delay). If a different manufacturer’s transformer is to be used, check its suitability for use with coil loads. See inrush and sealed VA ratings of the contactor coil. Standard engineering practice for Size 5 contactors is to use a Class 9070 Type EO-1 transformer and Class 8501 Type DO-20 control relay. A Class 9070 Type EO-3S2 transformer is an integral part of the Size 6 control circuit providing 120 volt control circuit voltage as standard on devices wired for common control. A Class 9070 Type EO-19-S2 transformer is an integral part of the size 7 control circuit providing 120 volt control circuit voltage as standard on devices wired for common control. AC Magnet Coils for AC Contactors and Starters Devices Using Coil NEMA Type Poles Size 00 0 1 2 3 4 5 6 7 u Coil Specification Number Suffix Numbers (Complete coil part number consists of specification number followed by suffix number as 31041-400-51.) 480 V/60 Hz 600 V/60 Hz 240 V/60 Hz 120 V/60 Hz 277 V/60 Hz 208 V/60 Hz 220 V/60 Hz 24 V/60 Hz 440 V/50 Hz 550 V/50 Hz 220 V/50 Hz 110 V/50 Hz SA SB SC All 31041-400- 20 42 48 All 31041-400- 20 42 48 All 31041-400- 20 42 48 3 31063-409- 16 38 44 SD 4-5 31063-400- 16 38 44 3 31074-400- 16 38 44 SE 4-5 31091-400- 16 38 44 SF All 31091-400- 16 38 44 SG 3 31096-400- . . . 09 15 SH 3 31104-400-50 (all voltages) SJ 3 31104-400-50 (all voltages) For 220 volt and 230 volt, 60 hertz applications, use 240 volt coil. u u u u u u u u u 51 51 51 47 47 47 47 47 18 52 52 52 49 49 49 49 49 19 60 60 60 57 57 57 57 57 24 62 62 62 60 60 60 60 60 29 47 5/98 © 1998 Square D All Rights Reserved AC Multispeed Magnetic Starters Application Data for Types SB-SJ – Class 8810, 8811, 8812 MECHANICAL INTERLOCK General Class 9999 Type SM-1 Mechanical Interlock For Two Contactors Horizontally Mounted Type S contactors or starters can be mechanically interlocked so that only one device will be energized at a time. The mechanical interlock is an interference (non-jamming) type, locking at the beginning of the stroke of any starter or contactor. Three unit mechanically interlocked contactors and/or starters are also available for various combinations of Sizes 0, 1 and 2. Type S Sizes 3, 4, 5 and 6 Overload Relay Mounting Bracket Mechanical interlock Types SM-1 through SM-10 for Sizes 00-2 devices use overload relay mounting brackets to support the overload relay portion of the starter. Class 9999 Type SM-12 For Sizes 3 and 4 Horizontally Mounted three pole contactors, a different version for four or five pole contactors. When adding a power pole to an existing three pole reversing contactor, a new mechanical interlock must also be installed. Type S Sizes 00, 0, 1 and 2 The mechanical interlock is mounted on the underside of the reversing baseplate. Two pins extend from the mechanical interlock through openings in the baseplate and engage the contact carrier of each contactor. Two styles of mechanical interlocks are used: one version for The mechanical interlock is separate from the mounting pan on Sizes 3-6. Cams on the mechanical interlocks are operated by the contact carrier of each contactor. The mechanical interlock is attached to the underside of the two contactors on Sizes 3 and 4; directly to the mounting pan on sizes 5 and 6. Size 5 and 6 mechanical interlocks are sold only as a factory assembly with the 8810 starter. The mechanical interlock utilizes a special baseplate and bracket that connects between the armatures. This is sold only as a factory assembly with the 8810 starter. Mechanical Interlock for Two Contactors Kit Description – The following kits consist of the mechanical interlock and base assembly for interlocking 2-5 pole contactors. Mechanical interlocks for horizontal and vertical mounting are listed for various pole arrangements. 4 Pole or 5 Pole 2 Pole or 3 Pole 2 Pole or 3 Pole Horizontal Type SM-1 for Size 00j, 0, or 1 Type SM-6 for Size 2 Type SM-12 for Sizes 3 & 4 4 Pole or 5 Pole j q 2 Pole or 3 Pole Horizontalt Type SM-2 for Size 0 or 1 Type SM-7 for Size 2 Type SM-12 for Sizes 3 & 4 4 Pole or 5 Pole Horizontal Type SM-3 for Size 0 or 1 Type SM-8 for Size 2 Type SM-12 for Sizes 3 & 4 t 4 Pole or 5 Pole 00j, 0, 1 0, 1 0, 1 0, 1 0, 1 SM-1 SM-2t SM-3 SM-4 SM-5 2 2 2 2 2 3 3, 4 4 SM-6 SM-7 SM-8 SM-9 SM-10 SM-11q SM-12q SM-13q 2 Pole or 3 Pole Verticalt Type SM-2 for Size 0 or 1 Type SM-10 for Size 2 Type SM-11 for Size 3 Type SM-13 for Size 4 2 Pole or 3 Pole 4 Pole or 5 Pole 2 Pole or 3 Pole 4 Pole or 5 Pole Vertical Type SM-4 for Size 0 or 1 Type SM-9 for Size 2 Type SM-11 for Size 3 Type SM-13 for Size 4 Contactor Class NEMA 9999 Size Type Horizontal Type SM-5 for Size 0 or 1 Type SM-11 for Size 3 Type SM-13 for Size 4 The type SM-2 interlock is factory assembled for horizontal mounting but can easily be converted to vertical mounting. Conversion instructions are included. For replacement only on the NEMA Size 00, reversing starters and contactors. Interlocks do not include mounting pan. Overload Relay Mounting Bracket Kit Description Type SO-11 Overload Relay Mounting Bracket Class 9999 Type Bracket for one overload relay used with horizontal mechanical interlocks, Types SM-1, SM-2, SM-3, SM-6, SM-7 and SM-8 SO-11 Bracket for two overload relays used with vertical mechanical interlocks, Types SM-2, SM-4, SM-5, SM-9 and SM-10 SO-12 48 © 1998 Square D All Rights Reserved 5/98 AC Two Speed Magnetic Starters Dimensions – Class 8810, 8811, 8812 Non-Reversing — Open Type Approximate Dimensions .50 A 13 7.00 C A D 178 E E F G .50 C 13 B D I H RESET B RESET RESET P .50 F I 13 Provision for (4) .31 Dia. Mounting Screws 8 H Travel M J L K G N K RESET J Figure 1 Class 8810, Sizes 0, 1 & 2 Types SBO, SCO & SDO .56 Reset Travel 14 6.25 159 Figure 2 Class 8810, Sizes 3 & 4 Types SEO and SFO A G F C E A F E G C B I I B D D H M M K J M N J (4) L Dia. Mounting Holes M M H Figure 3 Class 8810, Size 5 Type SGO Fig. NEMA Type No. Size 0 and 1 1 2 3 2 4 3 5 Mtg. A Holes IN K Figure 4 Class 8810, Size 6 Type SHO B C D mm IN mm IN mm IN E mm IN G H mm IN F mm IN mm IN I mm IN J N (4) L Dia. Mounting Holes K mm IN mm IN L mm IN M mm IN N mm IN 9.63 245 7.34 186 5.31 135 8.00 203 .63 16 ... ... .22 6 6.91 176 . . . ... .22 6 4.75 121 2.25 57 5.06 129 .59 15 SBO-3, 4 3 SCO-3, 4 7.13 181 6.91 176 5.31 135 . . . ... ... 3.41 87 .47 12 6.22 158 . . . ... .22 6 3.56 90 1.63 41 5.06 129 .59 15 SDO-1, 2 6 12.03 306 8.53 217 6.03 153 10.38 264 .50 13 ... .25 6 8.13 207 6.25 159 .16 4 5.75 146 2.81 71 5.16 131 .78 20 SDO-3, 4 3 9.00 229 8.06 205 6.03 153 . . . ... 4.50 114 .38 10 7.50 191 . . . 5 4.34 110 2.16 55 5.16 131 .78 20 SEO-1, 2 4 18.00 457 14.44 367 17.00 432 12.25 311 1.50 38 .69 18 .50 13 6.44 164 7.38 187 1.66 42 2.16 55 ... ... ... ... ... ... SEO-3, 4 4 12.75 324 12.28 312 11.75 298 10.75 273 1.03 26 .50 13 .50 13 2.50 64 6.75 171 1.16 29 1.16 29 ... ... ... ... ... ... SFO-1, 2 4 18.63 473 15.59 396 17.00 432 12.25 311 1.84 47 1.50 38 1.13 29 6.44 164 7.66 195 1.66 42 1.66 42 ... ... ... ... ... ... SFO-3, 4 4 14.25 362 14.59 371 13.25 337 12.25 311 1.84 47 .50 .50 13 2.94 75 1.66 42 ... ... ... ... ... ... SGO-1, 2t 4 29.28 744 20.28 515 9.38 238 5.41 137 1.28 33 28.00 711 .63 16 12.56 319 19.00 483 .63 15 22.53 572 .50 13 2.41 61 SGO-3, 4 4 19.28 490 20.28 515 9.38 238 5.14 137 1.28 33 18.00 457 .63 16 2.63 67 19.00 483 .63 15 12.53 318 .50 13 2.41 61 6.63 168 SHO-1, 2t 4 29.53 750 22.44 570 9.53 242 6.97 177 3.81 97 28.00 711 .75 19 11.63 295 21.19 538 .63 15 9.88 251 .56 14 3.03 77 9.31 236 SHO-3, 4 4 19.53 496 22.44 570 9.53 242 6.97 177 3.81 97 18.00 457 .75 19 1.69 43 15 9.88 251 .56 14 3.03 77 9.31 236 ... ... ... ... 13 ... .19 7.38 187 1.66 42 6.63 168 4 6q — 7f t Consequent pole, type starters consist of two 3-pole starters as pictured in Figure 3 and an additional 2-pole shorting contactor (not shown), all on a common base-plate, horizontally mounted. Current transformers used with Size 1 overload relay blocks. Solid state overloads and special current transformers. q f mm SBO-1, 2 4 SCO-1, 2 SJO-3, 4 21.19 538 .63 Consult Square D 49 5/98 © 1998 Square D All Rights Reserved AC Magnetic Starters Application Data – Class 8810, 8811, 8812 Non-Reversing — Non-Combination — Enclosed Approximate Dimensions A D (4) H Dia. Mounting Holes E G B RESET RESET F C Figure 1 NEMA Type 1 Enclosure – Figure 1 A B C D E F G H Type IN mm IN mm IN mm IN mm IN mm IN mm IN mm IN mm SBG and SCG 11.88 302 11.88 302 7.53 191 9.75 248 1.06 27 1.06 27 9.75 248 .31 8 SDG 14.88 378 14.13 359 7.66 195 12.75 324 1.06 27 1.06 27 12.00 305 .31 8 SEG-3 & -4 and SFG-3 & -4 18.16 461 29.16 741 9.23 234 15.50 394 1.34 34 1.34 34 26.50 673 .44 11 SEG-1 & -2 and SFG-1 & -2 22.16 563 39.16 995 10.23 260 19.50 495 1.34 34 1.34 34 36.50 927 .44 11 SGG-1, 2, 3, 4 20.22 514 65.75 1670 6.45 31.00 787 2.13 54 2.13 54 42.00 1067 .56 14 SHG-1, 2, 3, 4 36.22 920 62.22 1580 19.47 495 SJG-3 & 4 Consult Square D G H 164 Floor Mount A D E G B RESET RESET C F (4) H Dia. Mounting Holes Figure 2 NEMA Type 1 Enclosure – Figure 2 A B C D E F Type IN mm IN mm IN mm IN mm IN mm IN mm IN mm IN mm SBA and SCA 11.88 302 13.50 343 7.75 197 4.25 108 3.81 97 .38 10 12.75 324 .31 8 SDA 14.88 378 15.75 400 7.88 200 4.25 108 5.31 135 .38 10 15.00 381 .31 8 SEA-3 & -4 and SFA-3 & -4 18.16 461 31.50 800 9.59 244 16.00 406 3.09 78 .50 13 30.50 775 .44 11 SEA-1 & -2 and SFA-1 & -2 22.16 563 41.50 1054 10.59 269 16.00 406 3.09 78 .50 13 40.50 1029 .44 11 SGA-1, 2, 3, 4 35.22 895 49.00 1245 13.11 333 27.00 686 4.11 104 .50 13 48.00 1219 .56 14 SHA-1, 2, 3, 4 36.22 920 62.22 1580 19.47 495 SJA-3 & 4 Consult Square D Floor Mount 50 © 1998 Square D All Rights Reserved 5/98 AC Magnetic Starters Application Data – Class 8810, 8811, 8812 Non-Reversing — Non-Combination — Enclosed Approximate Dimensions A D E C G B RESET RESET J I F (4) H Dia. Mounting Holes Figure 3 NEMA Type 4 Enclosure – Figure 3 A B C D E F G H I J Type IN mm IN mm IN mm IN mm IN mm IN mm IN mm IN mm IN mm IN mm SBW and SCW 12.63 321 14.69 373 7.81 198 4.25 108 4.19 106 .59 15 13.50 343 .31 8 1.66 42 2.31 59 SDW 14.88 378 15.75 400 8.25 210 4.25 108 5.31 135 .38 10 15.00 381 .31 8 2.03 52 2.63 67 SEW-3 & -4 and SFW-3 & -4 18.16 461 32.22 818 8.77 223 12.00 305 3.08 78 .86 22 30.50 775 .44 11 2.58 66 3.19 81 SEW-1 & -2 and SFW-1 & -2 22.16 563 42.22 1072 9.77 248 16.00 406 3.08 78 .86 22 40.50 1029 .44 11 2.33 59 2.89 73 SGW-1, 2, 3, 4 35.22 895 49.22 1250 12.13 308 27.00 686 4.09 104 .61 15 48.00 1219 .56 14 2.98 76 3.50 89 Top View Rear View Space Required To Remove Top Cover N E Q Rear Seal R A (2) "L" Pipe Tap Top and Bottom G C F L D B Threaded Cover Enclosure Overload Reset H S K J T M Mtg. Holes and/or Slots (3) Circuit Breaker Operational Handle – Combination Form Only P (Add 1.00 Inch To Overall Width) Space Required To Remove Bottom Cover Figure 4 NEMA Type 7 & 9 Enclosure – Figure 4 A B C D IN mm IN mm IN mm IN E F G H mm IN mm IN J K L M N P R Type mm IN mm IN mm IN SCR-1, 2, 3 & 4 12.00 305 41.06 1043 68.06 1729 16.75 425 7.25 184 7.69 195 26.13 664 3.00 76 Std. & Form Y79-1 mm IN mm IN mm IN mm IN mm IN mm IN mm 24.00 610 8.50 216 2.06 52 9.38 238 5.25 133 1.50 38 .38 10 SCR-1, 2, 3 & 4 12.00 305 46.13 1172 79.13 2010 16.75 425 12.25 311 7.69 195 26.13 664 9.00 229 24.00 610 Forms T & TY79-1 8.50 216 2.06 52 9.38 238 5.25 133 1.50 38 .38 10 SDR-1, 2, 3 & 4 16.13 410 48.50 1232 81.50 2070 20.25 514 12.50 318 8.63 219 27.75 705 8.00 203 25.00 635 Std. & Form Y79-1 12.00 305 2.63 67 11.00 279 5.50 140 2.50 64 .38 10 SCR-1, 2, 3 & 4 Forms T & Y79-1 12.00 305 2.63 67 11.00 279 5.50 140 2.50 64 .38 10 16.13 410 50.50 1283 85.00 2159 20.25 514 9.13 232 8.63 219 32.75 832 4.50 114 30.00 762 For Sizes 3, 4 and 5 consult Square D field office. 51 5/98 © 1998 Square D All Rights Reserved AC Two Speed Combination Starters Disconnect Switch or Circuit Breaker Type – Class 8810, 8811, 8812 “Quick Ship Only” Approximate Dimensions NEMA Type 1 Enclosure – Figure 1 Dimensions — Inches/mm NEMA Class Type Size A B C D E Top & Bottom Sides F G H I J K L M N O P W X Y 0-1 8810 SBG SCG 13.88 353 23.13 588 8.25 210 10.63 270 21.00 533 19.28 490 1.88 48 1.88 48 3.75 95 2.31 59 1.06 27 3.30 84 2.19 56 1.25 32 .88 22 ... 1⁄2-3⁄4-1 1⁄2-3⁄4-1 1⁄2 2 8810 SDG 15.16 385 28.91 734 9.56 243 11.63 295 26.25 667 21.81 554 2.19 56 2.00 51 4.00 102 2.63 67 1.33 34 3.30 84 2.22 56 1.27 32 .91 23 ... 1-11⁄4 1⁄2-3⁄4 1⁄2 NEMA Type 4 Enclosure – Figure 2 Dimensions — Inches/mm Top & Bottom Bottom NEMA Size Class Type A B C D E F G H I J K L W 0-1 8810 SBW SCW 13.88 353 8.33 212 25.19 640 3.30 84 2.56 65 8.75 222 24.00 610 .59 15 3.95 100 1.63 41 2.31 59 18.53 471 3⁄4 Hub 1 Hub 2 8810 SDW 15.13 389 9.58 243 30.94 786 3.30 84 2.56 65 10.00 254 29.75 756 .59 15 3.95 100 2.00 51 2.63 67 21.03 534 3⁄4 Hub 11⁄2 Hub X NEMA Type 12 Enclosure – Figure 3 Dimensions — Inches/mm NEMA Class Type A B C Size IN mm IN mm IN 0-1 8810 SBA SCA 2 8810 SDA A E F G H I J IN mm IN mm IN mm IN mm IN mm IN mm IN mm 13.88 353 10.09 256 24.75 629 3.30 84 2.56 65 8.75 222 24.00 610 .38 10 3.95 100 20.28 515 15.16 385 10.97 279 31.25 794 3.30 84 3.08 78 9.00 229 30.25 768 .50 13 4.83 123 23.44 595 Handle Swing L M D D mm K A F C N E H Handle Swing D A F B E H Handle Swing D B Y O G C E B G C Y (4) .31 Dia. Mtg. Holes 8 (For Size 0, 1, & 2) (4) .31 Dia. Mtg. Holes 8 (For Size 0, 1, & 2) Cover Open 90° Cover Open 90° F L J W W X W G J (4) .31 Dia. Mtg. Holes 8 (For Size 0, 1, & 2) X J I H I Figure 1 NEMA Type 1 Enclosure K Figure 2 NEMA Type 4 Enclosure I Figure 3 NEMA Type 12 Enclosure 52 © 1998 Square D All Rights Reserved 5/98 Square D Company 8001 Highway 64 East Knightdale, NC 27545-9023 (919) 266-3671 UL is a registered trademark of Underwriters Laboratories, Inc. CSA is a registered trademark of Canadian Standards Association. MOTOR LOGIC is a trademark of Square D Company. Spin Top, Square D and are registered trademarks of Square D Company. Catalog No. 8502CT9701 May 1998 © 1998 Square D All Rights Reserved.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Create Date : 1998:05:08 18:33:34 Producer : Acrobat Distiller 3.01 for Power Macintosh Author : Big Daniel Title : Class 8502 Type S Creator : FrameMaker 5.5 Modify Date : 1998:05:08 18:51:20 Page Count : 54 Page Mode : UseOutlinesEXIF Metadata provided by EXIF.tools