101357 Catalog

113167-Catalog 113167-Catalog 113167-Catalog 785901 Batch7 unilog cesco-content

63371-Attachment 63371-Attachment 63371-Attachment 785901 Batch5 unilog cesco-content

2014-07-05

: Pdf 101357-Catalog 101357-Catalog 785901 Batch5 unilog

Open the PDF directly: View PDF PDF.
Page Count: 30

DE2-1
DE2 SAFETY SWITCHES
Safety Switches
04/14
Selection Guide
Contents Descriptions Page
General Information
Features and Benefits 2 - 3
Product Illustrations
General Duty, Light Duty Safety Switches & Air Conditioning Disconnects
120/240Vac 4 - 5
Heavy Duty Safety Switches
240Vac Fusible 6 - 7
600Vac Fusible & Non-Fusible 8 - 11
Heavy Duty Special Application Safety Switches
600Vac Fusible & Non-Fusible 12 - 13
MD Motor Disconnect Switches 14
RCD Switches 15
Heavy Duty Receptacle Switches
600Vac Fusible & Non-Fusible 16
1000 Vdc Photovoltaic Heavy Duty Disconnect Switch
IEC and UL98-B listed 17
NEMA 3 and IP63 Enclosure 17
Double Throw Safety Switches
240Vac & 600Vac Fusible & Non-Fusible 18 - 21
Accessories (Field/Factory Installed)
Heavy Duty Safety Switches 22 - 26
Double Throw Safety Switches - E-Series 27
Double Throw Safety Switches - F-Series 28
General Duty Safety Switches 29
Application Information
Safety Switches Enclosures 30
DE2_P01-17.fm Page 1 Monday, April 28, 2014 2:58 AM
DE2-2
Safety Switches
DE2 SAFETY SWITCHES
04/14
General Information
General Duty
Pages: DE2-4 to DE2-5
Application: Residential and light commercial.
240 Vac maximum.
30 through 600 Amperes.
Horsepower rated.
Short Circuit Ratings:
Plug Fuse - up to 10K RMS Symmetrical Amperes Fault Current
Class H, K Fuse - up to 10K RMS Symmetrical Amperes Fault Current
Class R, J Fuse - up to 100K RMS Symmetrical Amperes Fault Current
Service entrance rated.
Standards: CSA Certified under file numbers LL-89067 and LL-11815-108C
Enclosures: Types 1 and 3R
Features: Visible blades for positive indication that switch is “OFF”.
Quick-Make / Quick-Break operating mechanism.
Lugs suitable for AI or Cu conductors.
Phenolic insulating bases.
Multiple padlock provisions in the “OFF” position.
Spring reinforced plated copper fuse clips.
Accessories: “RB Hubs” for Type 3R enclosures.
Class R fuse kits.
Factory or field installable electrical interlock on 60 - 200 Amperes (for F-Series only).
Field installed fuse pullers on 60 & 100 Amperes.
See page DE2-29 for more information regarding accessories and optional features.
Heavy Duty
Pages: DE2-6 to DE2-11
Application: Commercial and industrial.
600 Vac or 600 Vdc maximum.
30 through 1200 Amperes.
Horsepower rated.
Short Circuit Ratings:
Class H, K Fuse - up to 10 K RMS Symmetrical Amperes Fault Current
Class J, R, L Fuse - up to 200 K RMS Symmetrical Amperes Fault Current
Standards: CSA Certified under file #’s LL-89067 and LL-97406-3.
Enclosures: Types 1, 3R, 4/4X and 3R/12
Features: In addition to General Duty....
Red and black handles indicate switch position.
Dual cover interlock.
Terminations for copper or aluminum and for copper only.
Accessories: In addition to General Duty....
Electrical interlocks factory or field installed.
Viewing Windows.
Factory or field installed fuse pullers.
Key interlock systems.
Factory installed push buttons.
Factory installed indicators of voltage presence on line/load side.
Lock-off guard.
Internal barrier kits.
See pages DE2-22 to DE2-26 for more information regarding accessories and optional features.
DE2_P01-17.fm Page 2 Monday, April 28, 2014 2:58 AM
DE2-3
DE2 SAFETY SWITCHES
Safety Switches
04/14
General Information
Double Throw
Pages: DE2-18 to DE2-21
Application: Manual transfer of a load between two power sources (or one power source
between two loads on series A, F DT & DTU only)
Residential, light commercial and industrial installations.
Up to 600 Vac or 600 Vdc maximum.
30 through 600 Amperes.
Standards: • cULus
Enclosures: Types 1, 3R, 4/4X and 12.
Features: Visible blades for positive indication switch is “OFF”.
Padlock provisions in the center “OFF” position.
Padlock provisions in the “ON” positions
Quick-Make / Quick-Break operating mechanism, Load-Make / Load-Break rated
on Types DT & DTU (series A, F), 82,000.
Dual cover interlock on the 82,000 line & A, F-Series devices with external defeat
mechanism
Series A, F, Types DT & DTU, supplied as standard for switching one load between
two power sources, and may be field converted to switch one power source
between two loads
Accessories: “RB” Bolt-on hubs for Type 3R enclosures.
Field installable service grounding kits for Series E switches. Included as standard
on Series F switches.
Neutral assemblies and electrical interlocks are available for field installation only
on series A, F, Types DT & DTU, 82,000.
Factory installed indicators of voltage presence on line/load side(s) on Types DT &
DTU (series F).
See pages DE2-27 and DE2-28 for more information regarding accessories and
optional features.
Special Applications
Pages: DE2-12 to DE2-14
Type 4X, non-metallic, corrosion resistant, fiberglass reinforced polyester enclosed
switches.
Type 7/9 enclosed switches, for hazardous locations.
Types 1 and 3R/12, 4-Pole safety switches (see pages DE2-10 and DE2-11).
Types 3R/12, 6-Pole safety switches (see pages DE2-10 and DE2-11).
Types 4/4X stainless steel and 3R/12 interlocked receptacle switches, with
Crouse-Hinds Arktite® Receptacles (see page DE2-14).
Types 4/4X stainless steel and 3R/12 interlocked receptacle switches,
with Appleton® Receptacles (see page DE2-14).
Arktite® is a Registered Trademark of Crouse-Hinds Company.
Appleton® is a Registered Trademark of Appleton Electric Limited.
DE2_P01-17.fm Page 3 Monday, April 28, 2014 2:58 AM
DE2-4
Safety Switches
DE2 SAFETY SWITCHES
04/14
General Duty, Light Duty & Air Conditioning Disconnects
Single Throw
120/240 Vac, 1-Pole, 2-Pole & 3-Pole
Fusible switches are suitable for use as service equipment except where marked .
Not suitable for use as service equipment.
Does not contain over current protection. Suitable for use on systems with up to 10,000 RMS Symmetrical Amperes available fault current at 240Vac max when
protected by a fuse or circuit breaker rated 60A or less.
Type 3R Switches with ”RB” suffix are supplied with main entry hole cut in top endwall and closing cap (BCAP) installed. Hole accepts 3/4 in. to 2 1/2 in. hubs.
“Ser.” denotes the Series of the device. Please refer to this column when selecting accessories.
For 200% neutral, order (1) additional neutral kit CSN20, and (1) neutral jumper kit SN20NI.
* For installing class J fuses:
- Relocation of the load side fuse base assembly is required in 100-400 A, 240V switches
- Additional of an adapter kit GDJK600 is required in 600A switches.
HP Rating r
System Amps Type of Voltage Ser. Type 1 Ser. Type 3R Std. Max.
Fuse Vac 1313
Light Duty Switches
30 Plug 120 E2 L111N ---- ---- 0.5 ---- 2 ----
General Duty 2-Pole + S/N
30 Plug 120/240 E2 CD211N ---- ---- 1.5 ---- 3 ----
30 E2 CD221N ---- ---- 1.5 ---- 3 ----
60 F1 CD222N F1 CD222NRB 3 ---- 10 ----
100 Cartridge 120/240 F3 CD223N F3 CD223NRB 7.5 ---- 15 ----
200 F1 CD224N F1 CD224NRB 15 ---- ---- ----
400 E3 CD225N E1 CD225NR ---- ---- ---- ----
600 E3 CD226N E1 CD226NR ---- ---- ---- ----
General Duty 3-Pole + S/N
30 E3 CD321N E3 CD321NRB 1.5 3 3 7.5
60 F1 CD322N F1 CD322NRB 3 7.5 10 15
100 Cartridge 120/240 F3 CD323N F3 CD323NRB 7.5 15 15 30
200 F1 CD324N F1 CD324NRB 15 25 ---- 60
400 E3 CD325N E1 CD325NR ---- 50 ---- 125
600 E3 CD326N E1 CD326NR ---- 75 ---- 150
Unfused Air Conditioning Disconnect - Moulded Case Switch
60 ---- 240 ---- ---- G3 CQO200TR ---- ---- 10 ----
Application Information
rHP Ratings:
- Standard - using fast acting one time fuses
- Maximum - using time delay fuses
General Duty Switches have Quick-Make / Quick-Break
operating mechanisms and Load-Make / Load-Break rated.
Light Duty Switches have Slow-Make / Slow-Break operat-
ing mechanisms and are Load-Make / Load-Break rated.
For information regarding accessories and optional
features, see page DE2-29.
For more information consult Schneider Electric.
Short Circuit Withstand Ratings
RMS Symmetrical k Amps
Fuse Class
Voltage Plug H K J R
240 Vac 10 10 10 100 100
Class J fuse provisions available on 400 & 600A only,
(page DE2-29).

DE2_P01-17.fm Page 4 Monday, April 28, 2014 2:58 AM
DE2-5
Safety Switches
DE2
S
AFETY SWITCHES
04/14
General Duty
Single Throw
120/240 Volt
Approximate Dimensions - Light Duty Type 1
Catalogue Height (H) Width (W) W/H Depth (D)
Number in./mm in./mm in./mm in./mm
L111N 7.63/194 5.00/127 6.13/156 4.00/102
Approximate Dimensions - General Duty Type 1
Ampere Height (H) Width (W) W/H Depth (D)
Rating in./mm in./mm in./mm in./mm
30 9.25/235 6.75/171 7.25/184 3.63/92
60 14.63/372 6.50/165 7.45/189 4.88/124
100 17.50/445 8.50/216 10.50/267 6.50/165
200 29.00/737 17.25/438 19.00/483 8.25/210
400 45.12/1146 24.00/610 24.88/632 8.88/226
600 49.13/1248 24.00/610 24.88/632 8.88/226
Approximate Dimensions - General Duty Type 3R
Ampere Height (H) Width (W) W/H Depth (D)
Rating in./mm in./mm in./mm in./mm
30 9.63/245 7.25/184 7.75/197 3.75/95
60 14.88/378 6.63/168 7.45/189 4.88/124
100 17.50/445 8.50/216 10.50/267 6.50/165
200 29.25/743 17.25/438 19.00/483 8.25/210
400 30.63/778 21.38/543 22.25/565 10.13/257
600 49.13/1248 24.75/629 25.13/638 8.88/226
Terminal Lug Data
Ampere
Rating
Conductors
per Phase
Wire Range
AWG/Kcmil
30 1 # 12 - 6 (Al) or # 14 - 6 (Cu)
60 1 # 10 - 3 (Al) or # 14 - 3 (Cu)
100 1 # 12 - 1 (Al) or # 14 - 1 (Cu)
200 1 # 6 - 250 (Al/Cu)
400
Type 1
1
or
2
#1/0 - 750 (Al/Cu) or
#1/0 - 300 (Al/Cu)
400
Type 3R 2 #1/0 - 250 (Al/Cu)
600 2 # 4 - 500 (Al/Cu)
Optional wire range: (1) 1/0 - 600 or, (2) 1/0 - 500 or (4) 1/0 - 250 when lug kit GD 4060 LK is used. Kit applicable to Type 1 enclosures only.
30-100 Amp switches suitable for 60º or 75ºC conductors. 200-600 Amp switches suitable for 75ºC conductors.
Typical Type 1 Enclosure
Typical Type 3R Enclosure
Approximate Dimensions - Air Conditioning Disconnects
Ampere Height (H) Width (W) Depth (D) Conductors Wire
Rating in./mm in./mm in./mm Per Phase Range
CQ0200TR 60 6.50/165 4.63/118 3.88/99 1 #14-#4 Al/Cu
Application Information
Dimensions are approximate only. Do not use for construction.
DE2_P01-17.fm Page 5 Monday, April 28, 2014 2:58 AM
DE2-6
Safety Switches
DE2 SAFETY SWITCHES
04/14
Heavy Duty
Single Throw - Fusible
240 Vac, 250 Vdc, 2-Pole & 3-Pole
Type 3R switches with “RB” suffix are supplied with main entry hole cut in top endwall and closing cap (BCAP) installed. Hole accepts 3/4 in. to 2 1/2 in. hubs.
Type 3R switches with “R” suffix have a blank endwall.
Type 3R/12 switches are suitable for Type 3R application by removing the drainscrew from bottom endwall.
“Ser.” denotes the Series of the device. Please refer to this column when selecting accessories.
For switching DC, use any two switching poles.
Fusible switches 240V are suitable for use as service equipment.
For installing class J fuses:
- Relocation of the load side fuse base assembly is required in 100-400 A, 240V switches.
- Addition of an adapter kit H600J is required in 600A switches.
30-600 A 240V switches accept class R fuses as standard.
For class R fuse rejection kit information please refer to page DE2-22.
Type 3R/12, 4/4X 30-200A are supplied with viewing window standard.
HP Rating r
System Amps Fuse
Type
Provision
Ser. Type 1 Ser. Type 3R Ser. Type 4/4X Ser. Type 3R/12 240 Vac 250 Vdc
Stainless Steel Std. Max.
1Ø 3Ø
2-Pole + S/N
30 H F5 CH221N F5 CH221NRB - - F6 CH221NAWK 1.5 3 5
60 H F5 CH222N F5 CH222NRB - - F6 CH222NAWK 310 10
100 H F5 CH223N F5 CH223NRB - - F6 CH223NAWK 7.5 15 20
200 H F5 CH224N F5 CH224NRB - - F6 CH224NAWK 15 - 40
400 H E4 CH225N E5 CH225NR - - E4 CH225NAWK - - 50
600 H E4 CH226N E5 CH226NR - - E4 CH226NAWK - - 50
800 L E4 H227N E4 H227NR - - E4 H227NAWK 50 50 50
1200 L E4 H228N E4 H228NR - - E4 H228NAWK 50 50 50
3-Pole + S/N
1Ø 3Ø
30 H F5 CH321N F5 CH321NRB F6 CH321NDS F6 CH321NAWK 1.5 3 3 7.5 5
60 H F5 CH322N F5 CH322NRB F6 CH322NDS F6 CH322NAWK 3 7.5 10 15 10
100 H F5 CH323N F5 CH323NRB F6 CH323NDS F6 CH323NAWK 7.5 15 15 30 20
200 H F5 CH324N F5 CH324NRB F6 CH324NDS F6 CH324NAWK 15 25 - 60 40
400 H E4 CH325N E5 CH325NR E4 CH325NDS E1 CH325NAWK - 50 - 125 50
600 H E4 CH326N E5 CH326NR E4 CH326NDS E4 CH326NAWK - 75 - 200 50
800 L E4 H327N E4 H327NR - - E4 H327NAWK 50 100 50 250 50
1200 L E4 H328N E4 H328NR - - E4 H328NAWK 50 100 50 250 50
Application Information
rHP Ratings:
- Standard - using fast acting one time fuses
- Maximum - using time delay fuses
- refer to latest design series only
Heavy Duty Switches have Quick-Make / Quick-Break
operating mechanisms Load-Make / Load-Break rated.
For information regarding accessories and optional
features, see pages DE2-22 to DE2-26.
For more information consult Schneider Electric. iApply to AC only.
Short Circuit Current Ratings i
RMS Symmetrical k Amps
Fuse Class
Voltage H J L R
600 Vac 10 200 200 200
DE2_P01-17.fm Page 6 Monday, April 28, 2014 2:58 AM
DE2-7
DE2 SAFETY SWITCHES
Safety Switches
04/14
Heavy Duty
Single Throw - Fusible
240 Vac, 250 Vdc
Approximate Dimensions - Type 1
Ampere
Rating
Height (H)
in./mm
Width (W)
in./mm
W/H
in./mm
Depth (D)
in./mm
30 14.60/371 6.50/165 7.55/192 4.88/124
60 14.60/371 6.50/165 7.55/192 4.88/124
100 21.25/540 8.50/216 10.50/267 6.38/162
200 29.00/737 17.13/435 18.50/470 8.25/210
400 2-pole 50.25/1276 27.63/702 27.63/702 10.13/257
400 3-pole 50.25/1276 27.88/708 27.88/708 10.13/257
600 50.25/1276 27.63/702 27.63/702 10.13/257
800 69.13/1756 36.62/930 36.63/929 17.75/451
1200 69.13/1756 36.62/930 36.63/929 17.75/451
Approximate Dimensions - Type 3R
Ampere
Rating
Height (H)
in./mm
Width (W)
in./mm
W/H
in./mm
Depth (D)
in./mm
30 14.88/378 6.63/168 7.55/192 4.88/124
60 14.88/378 6.63/168 7.55/192 4.88/124
100 21.25/540 8.50/216 10.50/267 6.38/162
200 29.25/743 17.25/438 18.63/473 8.50/216
400 50.31/1278 27.76/705 27.76/705 9.53/257
600 50.31/1278 27.76/705 27.76/705 9.53/257
800 69.13/1756 36.62/930 36.63/929 17.75/451
1200 69.13/1756 36.62/930 36.63/929 17.75/451
Approximate Dimensions - Type 4/4X
Ampere
Rating
Height (H)
in./mm
Width (W)
in./mm
W/H
in./mm
Depth (D)
in./mm
30 14.93/379 7.22/183 8.67/220 5.11/130
60 14.93/379 7.22/183 8.67/220 5.11/130
100 20.82/529 9.36/238 11.25/286 6.97/177
200 29.00/737 17.75/451 19.25/489 8.88/226
400 46.25/1175 26.25/667 26.25/667 10.13/259
600 46.25/1175 26.25/667 26.25/667 10.13/259
800----
1200 ----
Approximate Dimensions - Type 3R/12
Ampere
Rating
Height (H)
in./mm
Width (W)
in./mm
W/H
in./mm
Depth (D)
in./mm
30 14.60/371 6.63/168 7.55/192 4.96/126
60 14.60/371 6.63/168 7.55/192 4.96/126
100 20.50/521 9.00/229 10.50/267 7.00/178
200 29.00/737 17.25/438 18.63/473 8.75/216
400 46.25/1175 26.25/667 26.25/667 10.13/259
600 46.25/1175 26.25/667 26.25/667 10.13/259
800 69.13/1756 36.63/929 36.63/929 17.75/451
1200 69.13/1756 36.63/929 36.63/929 17.75/451
Typical 30-200 A Type 1 Enclosure
Application Information
Dimensions are approximate only. Do not use for construction.
For terminal lug data refer to page DE2-25.
Typical 30-200 A Type 4, 4X, 5, 12 Enclosure
(Stainless has flat front)
Typical 30-200 A Type 3R Enclosure
DE2_P01-17.fm Page 7 Monday, April 28, 2014 2:58 AM
DE2-8
Safety Switches
DE2 SAFETY SWITCHES
04/14
Heavy Duty
Single Throw - Fusible & Non-Fusible
600 Vac, 600 Vdc, 3-Pole
Type 3R switches with “RB” suffix are supplied with main entry hole cut in top endwall and closing cap (BCAP) installed. Hole accepts 3/4 in. to 2 1/2 in. hubs.
Type 3R switches with “R” suffix have a blank endwall.
Type 3R/12 switches are suitable for Type 3R application by removing the drainscrew from bottom endwall.
“Ser.” denotes the Series of the device. Please refer to this column when selecting accessories.
30-200 A switches are silicone free devices.
Fusible switches are suitable for use as service equipment when installed with a neutral kit (page DE2-23).
Provisions for installing class H, R fuses are included in 30-200 A 600V fusible switches. Relocation of the load side fuse base assembly is required.
For installing class J fuses:
- Relocation of the load side fuse base assembly is required in 400A, 600V fusible switches.
- Addition of an adapter kit H600J is required in 600A, 600V fusible switches.
Use outside two poles for switching DC.
Type 3R/12, 4/4X are supplied with viewing window standard.
HP Rating r
System Amps
Fuse
Type
Provi-
sion
Ser. Type 1 Ser. Type 3R Ser. Type 4/4X Ser. Type 3R/12 240 Vac 480 Vac 600Vac
250
Vdc
600
Vdc
Stainless Steel Std. Max. Std. Max. Std. Max 
3-Pole, Fusible
30 J F5 CH361 F5 CH361RB F6 CH361DS F5 CH361AWK - - 5 15 7.5 20 5 15
60 J F5 CH362 F5 CH362RB F6 CH362DS F6 CH362AWK - - 15 30 15 50 10 30
100 J F5 CH363 F5 CH363RB F6 CH363DS F6 CH363AWK - - 25 60 30 75 20 50
200 J F5 CH364 F5 CH364RB F6 CH364DS F6 CH364AWK - - 50 125 60 150 40 50
400 H E4 CH365 E4 CH365R E4 CH365DS E4 CH365AWK - - 100 250 125 350 50 50
600 H E4 CH366 E4 CH366R E4 CH366DS E4 CH366AWK - - 150 400 200 500 50 50
800 L E4 H367 E4 H367R - - E4 H367AWK - - 200 500 250 500 50 50
1200 L E4 H368 E4 H368R - - E4 H368AWK - - 200 500 250 500 50 50
3-Pole, Non-Fusible
1Ø 3Ø
30 - F5 CHU361 F5 CHU361RB F6 CHU361DS F6 CHU361AWK 5 10 7 1/2 20 10 30 5 15
60 - F5 CHU362 F5 CHU362RB F6 CHU362DS F6 CHU362AWK 10 20 25 50 30 60 10 30
100 - F5 CHU363 F5 CHU363RB F6 CHU363DS F6 CHU363AWK 20 40 40 75 40 100 20 50
200 - F5 CHU364 F5 CHU364RB F6 CHU364DS F6 CHU364AWK 15 60 50 125 50 150 40 50
400 - E4 CHU365 E5 CHU365R E4 CHU365DS E4 CHU365AWK - 125 - 250 - 350 50 50
600 - E4 CHU366 E5 CHU366R E4 CHU366DS E4 CHU366AWK - 200 - 400 - 500 50 50
800 - E4 HU367 E4 HU367R - - E4 HU367AWK 50 250 50 500 50 500 50 50
1200 - E4 HU368 E4 HU368R - - E4 HU368AWK 50 250 50 500 50 500 50 50
Application Information
rHp Ratings for fusible switches:
- Standard - using fast acting one time fuses
- Maximum - using time delay fuses
- refer to latest design series only
Heavy Duty Switches have Quick-Make / Quick-Break
operating mechanisms Load-Make / Load-Break rated.
For information regarding accessories and optional
features, see pages DE2-22 to DE2-26.
For more information consult Schneider Electric.
lFor CSA certified short-circuit current rating for Square D
Heavy Duty, Non Fused switches, please refer to page
DE2-22.
iApply to AC only.
Short Circuit Current Ratings l i
RMS Symmetrical k Amps
Fuse Class
Voltage H J L R
600 Vac 10 200 200 200
DE2_P01-17.fm Page 8 Monday, April 28, 2014 2:58 AM
DE2-9
DE2 SAFETY SWITCHES
Safety Switches
04/14
Heavy Duty
Single Throw - Fusible & Non-Fusible
600 Volt
Approximate Dimensions - Type 1
Ampere Height (H) Width (W) W/H Depth (D)
Rating in./mm in./mm in./mm in./mm
30 14.60/371 6.50/165 7.55/192 4.88/124
60 17.50/445 9.00/229 10.50/267 6.38/162
100 21.25/540 8.50/216 10.50/267 6.38/162
200 29.00/737 17.13/435 18.50/470 8.25/210
400 50.25/1276 27.63/702 27.63/702 10.13/257
600 50.25/1276 27.63/702 27.63/702 10.13/257
800 69.13/1756 36.62/930 36.62/930 17.75/451
1200 69.13/1756 36.62/930 36.62/930 17.75/451
Approximate Dimensions - Type 3R
Ampere Height (H) Width (W) W/H Depth (D)
Rating in./mm in./mm in./mm in./mm
30 14.88/378 6.63/168 7.55/192 4.88/124
60 17.50/445 9.00/229 10.50/267 6.38/162
100 21.25/540 8.50/216 10.50/267 6.38/162
200 29.25/743 17.25/438 18.63/473 8.50/216
400 50.31/1278 27.76/705 27.76/705 9.53/257
600 50.31/1278 27.76/705 27.76/705 9.53/257
800 69.13/1756 36.62/930 36.62/930 17.75/451
1200 69.13/1756 36.62/930 36.62/930 17.75/451
Approximate Dimensions - Type 4/4X
Ampere Height (H) Width (W) W/H Depth (D)
Rating in./mm in./mm in./mm in./mm
30 14.93/379 7.22/183 8.67/220 5.11/130
60 16.87/428 8.92/227 10.81/275 6.97/177
100 20.82/529 9.36/238 11.25/286 6.97/177
200 29.00/737 17.75/451 19.25/489 8.88/226
400 46.25/1175 26.25/667 26.25/667 10.13/259
600 46.25/1175 26.25/667 26.25/667 10.13/259
800----
1200 ----
Approximate Dimensions - Type 3R/12
Ampere Height (H) Width (W) W/H Depth (D)
Rating in./mm in./mm in./mm in./mm
30 14.60/371 6.63/168 7.55/192 4.96/126
60 16.50/419 9.00/229 10.50/267 7.00/178
100 20.50/521 9.00/229 10.50/267 7.00/178
200 29.00/737 17.25/438 18.63/473 8.75/216
400 46.25/1175 26.25/667 26.25/667 10.13/259
600 46.25/1175 26.25/667 26.25/667 10.13/259
800 69.13/1756 36.62/930 36.62/930 17.75/451
1200 69.13/1756 36.62/930 36.62/930 17.75/451
Typical Type 1 Enclosure
Typical Type 3R Enclosure
Application Information
Dimensions are approximate only. Do not use for construction.
For terminal lug data refer to page DE2-25.
Typical Type 4, 4X, 5, 12 Enclosure
(Stainless has flat front)
DE2_P01-17.fm Page 9 Monday, April 28, 2014 2:58 AM
DE2-10
Safety Switches
DE2 SAFETY SWITCHES
04/14
Heavy Duty
Single Throw - Fusible & Non-Fusible
600Volt,4&6Pole(Not Suitable for Service Equipment)
Type 3R/12 Switches are suitable for type 3R application by removing the drainscrew from bottom endwall.
“Ser.” denotes the Series of the device. Please refer to this column when selecting accessories.
30-200 A switches are silicone free devices.
Not suitable for use as service equipment.
Use outside two poles for switching DC
For applications requiring motor disconnect capability, use electrical interlock. Refer to page DE2-24.
No knockouts are provided
HP rating for Non-Fusible switches are 2Ø & 3Ø (Not Std & Max).
s600 Vac only
HU461AWK (Series E1) is rated 5 HP@250 Vdc, 10HP@600 Vdc.
HP Rating r
System Amps Fuse
Type
Provi-
sion
Ser. Type 1 Ser. Type 3R Ser. Type 4/4X Ser. Type 3R/12 240
Vac
480
Vac
600
Vac
250
Vdc
600
Vdc
Stainless Steel
Std. Max. Std. Max. Std. Max. 
4-Pole, Fusible
30 H F5 H461 - - F6 H461DS F6 H461AWK - - 7 1/2 20 10 25 5 15
60 H F5 H462 - - F6 H462DS F5 H462AWK - - 15 40 20 50 10 30
100 H F5 H463 - - F6 H463DS F6 H463AWK - - 25 50 30 75 20 30
200 H F5 H464 - - F6 H464DS F6 H464AWK - - 50 - 50 - 40 50
400 H E4 CH465 s- - - - E4 CH465AWK s------ - -
600 H E4 CH466 s- - - - - - ------- -
4-Pole, Non-Fusible
30 - F5 HU461 - - F6 HU461DS E1 HU461AWK 10 10 20 20 25 30 1015
60 - F5 HU462 - - F6 HU462DS F6 HU462AWK 20 20 40 50 50 60 10 30
100 - F5 HU463 - - F6 HU463DS F6 HU463AWK 30 40 50 75 50 75 20 30
200 - F5 HU464 - - F6 HU464DS F6 HU464AWK 50 60 50 125 50 150 40 50
400 - E4 CHU465 s- - - - E4 CHU465AWK s------- -
600 - E4 CHU466 s- - - - E4 CHU466AWK s------- -
6-Pole, Fusible
30 - - - - - - - - - - - - - - - - -
60 - - - - - - - - - - - - - - - - -
100 H - - - - F6 H663DS F6 H663AWK - - 25 60 30 75 - -
200 H - - - - F6 H664DS F6 H664AWK ------ - -
6-Pole, Non-Fusible
30 - - - - - F6 HU661DS F6 HU661AWK - 10 - 20 - 30 - -
60 - - - - - F6 HU662DS F6 HU662AWK - 20 - 50 - 60 - -
100 - - - - - F6 HU663DS F6 HU663AWK - 40 - 75 - 75 - -
200 - - - - - F6 HU664DS F6 HU664AWK - 60 - 125 - 150 - -
Application Information
rHP Ratings for Fusible Switches:
- Standard - using fast acting one time fuses
- Maximum - using time delay fuses
- refer to latest design series only
Heavy Duty Switches have Quick-Make / Quick-Break
operating mechanisms Load-Make / Load-Break rated.
For information regarding accessories and optional
features, see pages DE2-22 to DE2-26.
For more information consult Schneider Electric.
lThe CSA certified short-circuit current rating for Square D
Heavy Duty, Non Fused switches, please refer to page
DE2-22.
Short Circuit Current Ratings l i
RMS Symmetrical k Amps
Fuse Class
Voltage H J L R
600 Vac 10 200 200 200
i Apply to AC only.
DE2_P01-17.fm Page 10 Monday, April 28, 2014 2:58 AM
DE2-11
DE2 SAFETY SWITCHES
Safety Switches
04/14
Heavy Duty
Single Throw - Fusible & Non-Fusible
600 Volt, 4 & 6-Pole
Except HU461AWK.
Approximate Dimensions - 4-Pole, Type 1
Ampere Height (H) Width (W) W/H Depth (D)
Rating in./mm in./mm in./mm in./mm
30 20.50/521 14.75/375 16.13/410 6.85/174
60 20.50/521 14.75/375 16.13/410 6.85/174
100 20.50/521 14.75/375 16.13/410 6.85/174
200 29.00/737 23.25/591 24.88/632 8.75/222
400 50.25/1276 33.88/861 33.88/861 10.13/257
600 50.25/1276 33.88/861 33.88/861 10.13/257
Approximate Dimensions - 4-Pole, Type 4/4X
Ampere Height (H) Width (W) W/H Depth (D)
Rating in./mm in./mm in./mm in./mm
30 20.82/529 15.08/383 16.85/428 6.85/174
60 20.82/529 15.08/383 16.85/428 6.85/174
100 20.82/529 15.08/383 16.85/428 6.85/174
200 29.00/737 23.75/603 25.25/641 8.88/226
Approximate Dimensions - 4-Pole, Type 3R/12
Ampere Height (H) Width (W) W/H Depth (D)
Rating in./mm in./mm in./mm in./mm
3020.50/521 14.75/375 16.13/410 6.80/173
HU461AWK 16.63/422 9.88/251 11.00/279 6.13/156
60 20.50/521 14.75/375 16.13/410 6.80/173
100 20.50/521 14.75/375 16.13/410 6.80/173
200 29.00/737 23.25/591 24.88/632 8.75/222
400 46.25/1175 32.50/826 32.50/826 10.13/259
600 46.25/1175 32.50/826 32.50/826 10.13/259
Approximate Dimensions - 6-Pole, Type 4/4X
Ampere Height (H) Width (W) W/H Depth (D)
Rating in./mm in./mm in./mm in./mm
30 20.82/529 15.08/383 16.85/428 6.97/177
60 20.82/529 15.08/383 16.85/428 6.97/177
100 20.82/529 15.08/383 16.85/428 6.97/177
200 29.00/737 23.75/603 25.25/641 8.88/226
Approximate Dimensions - 6-Pole, Type 3R/12
Ampere Height (H) Width (W) W/H Depth (D)
Rating in./mm in./mm in./mm in./mm
30 20.50/521 14.75/375 16.13/410 6.80/173
60 20.50/521 14.75/375 16.13/410 6.80/173
100 20.50/521 14.75/375 16.13/410 6.80/173
200 29.00/737 23.25/591 24.88/632 8.75/222
Typical Type 1 Enclosure
Typical Type 3R Enclosure
Application Information
Dimensions are approximate only. Do not use for construction.
For terminal lug data refer to page DE2-25.
Typical Type 4, 4X, 5, 12 Enclosure
(Stainless has flat front)
DE2_P01-17.fm Page 11 Monday, April 28, 2014 2:58 AM
DE2-12
Safety Switches
DE2 SAFETY SWITCHES
04/14
Heavy Duty, Special Application
Single Throw
600 Volt, 3-Pole
316 Grade Stainless Steel–Type 3, 3R, 4, 4X, 5, 12
Type 316 stainless steel enclosure safety switches offer superior corrosion resistance to a wider range of chemicals than Type 304 stainless switches. Type 316 resists chloride
attacks and is often used in marine, waste treatment and transportation applications. Use watertight hubs from page DE2-24. Equipment ground lugs are supplied as standard.
(For Type 304 stainless switches see page DE2-8.) Fusible switches are suitable for use as service equipment when installed with a neutral kit (page DE2-23).
3-pole 600 Vac, 600 Vdc
Fiberglass Reinforced Polyester Enclosures - Type 4X
Fiberglass Reinforced Polyester enclosures are watertight, corrosion resistant and impervious to windblown dust, rain, and splashing liquid. The moulded fiberglass is
extremely stable in a wide range of operating temperatures and can withstand heavy impact. Switches are furnished with hubs and equipment ground lugs. Fusible
switches are suitable for use as service equipment when installed with a neutral kit (page DE2-23).
Includes PKDB-1, breather and drain kit, required for rain proof application - Type 7 only.
Electrical Interlocks not available. For auxiliary switches, add 1212 suffix to standard switch catalogue number and price adder (e.g. H60XFA1212)
Auxiliary Interlocks factory Installed only.
Not CSA certified or UL listed due to wire bending space requirements.
“Ser.” denotes the Series of the device. Please refer to this column when selecting accessories.
cULus listed.
HP Rating 3Ø r
System Amps Fuse Type
Provision Ser. Catalogue
Number
480 Vac 600 Vac 600 Vdc
Std. Max. Std. Max. Max.
Fusible
30 H F6 H361SS 5 15 7.5 20 15
60 H F6 H362SS 15 30 15 50 30
100 H F6 H363SS 25 60 30 75 50
200 H F6 H364SS 50 125 60 150 50
Non-Fusible
30 - F6 HU361SS - 20 - 30 15
60 - F6 HU362SS - 50 - 60 30
100 - F6 HU363SS - 75 - 100 50
200 - F6 HU364SS - 125 - 150 50
HP Rating 3Ø
System Amps Fuse Type
Provision Ser. Catalogue
Number
480 Vac 600 Vac 600 Vdc
Std. Max. Std. Max. Max.
Fusible
30 H F1 H361DF 5 15 7.5 20 15
60 H F1 H362DF 15 30 15 50 30
100 H F1 H363DF 25 60 30 75 50
200 H E1 H364DF 50 125 60 150 50
Non-Fusible
30 - F1 HU361DF - 20 - 30 15
60 - F1 HU362DF - 50 - 60 30
100 - F1 HU363DF - 75 - 100 50
200 - E1 HU364DF - 125 - - 50
Type 7/9 Enclosures
An enclosed automatic moulded case switch for use in a Class I, Groups C & D. Division 1 or 2, (Type 7); Class II, Groups E, F, & G, Division 1 or 2, (Type 9); or Class
III, Division 1 or 2, (Type 9).
Furnished with threaded conduit openings in both top and bottom endwall (page DE2-13).
Not suitable for use as service equipment, and listed as “Raintight” for outdoor applications.
3-Pole, Unfused, 600Vac, 250Vdc Maximum, Short Circuit Rating 10 000 AIR.
HP Rating 3Ø
System Amps Ser. Catalogue
Number
240 Vac 480 Vac 600 Vac
60 E1 H60XFA 15 30 50
100 E1 H100XFA 30 60 75
225A A1 H225XJG  60 125 150
Application Information
rHP Ratings:
- Standard - using fast acting one time fuses
- Maximum - using time delay fuses
- refer to latest design series only
Heavy Duty Switches have Quick-Make / Quick-Break
operating mechanisms Load-Make / Load-Break rated.
For information regarding accessories and optional
features, see pages DE2-22 to DE2-26.
For more information consult Schneider Electric.
lThe CSA certified short-circuit current rating for Square D
Heavy Duty, Non Fused switches is based on the switch
being used in conjunction with fuses. Evaluation of not
fused switches in conjunction with molded case circuit
breakers has not been performed. If a CSA certified short-
circuit current rating is required, this not fused switch must
be replaced with a SQUARE D Heavy Duty Fusible safety
switch equipped with the appropriate class and size fus-
ing. Consult the wiring diagram of the switch to verify the
CSA certified short-circuit current rating.
Short Circuit Current Ratings l i
RMS Symmetrical k Amps
Fuse Class
Voltage H J L R
600 Vac 10 200 200 200
i Apply to AC only.
DE2_P01-17.fm Page 12 Monday, April 28, 2014 2:58 AM
DE2-13
DE2 SAFETY SWITCHES
Safety Switches
04/14
Heavy Duty, Special Application
Single Throw
600 Volt, 3-Pole
Hubs and hub drilling templates are provided for field installation (Type 4X).
Threaded conduit opening (Type 7/9).
Approximate Dimensions - Fiberglass-reinforced Polyester-Type 4X
Ampere Height (H) Width (W) W/H Depth (D)
Rating in./mm in./mm in./mm in./mm
30 16.50/419 11.00/279 11.00/279 8.80/224
60 16.50/419 11.00/279 11.00/279 8.80/224
100 24.80/630 13.70/348 13.70/348 12.00/304
200 31.30/795 26.30/668 26.30/668 11.80/300
Approximate Dimensions - Type 7/9 Enclosures
Ampere Height (H) Width (W) W/H Depth (D)
Rating in./mm in./mm in./mm in./mm
60 15.93/405 9.87/251 9.87/251 6.96/177
100 15.93/405 9.87/251 9.87/251 6.96/177
200 22.56/573 10.88/277 10.88/277 7.75/197
Conduit Provisions - Type 4X and Type 7/9
Ampere Rating Top/Bottom Endwall
Type 4X Type 7/9
30 3/4” -
60 1 1/4” 3/4”
100 2” 1 1/4”
200 2 1/2” 2 1/2”
H
WD
H
W D
Typical Type 4X
Fibreglass-reinforced Polyester Enclosure
Typical Type 7/9 Enclosure
DE2_P01-17.fm Page 13 Monday, April 28, 2014 2:58 AM
DE2-14
Safety Switches
DE2 SAFETY SWITCHES
04/14
Heavy Duty, Special Application
Motor Disconnect Switches
The MD motor disconnect switch is CSA C22.2 No. 14 Suitable For Motor Control. It is in a
compact NEMA 4X enclosure suitable for use in NEMA Type 1, 3, 3R, 4, 4X and 12
applications. The MD's key benefits are an extremely small footprint, a more economically
efficient NEMA 4X solution and a handle interlock preventing cover removal when the
switch is in the ON position.
Complies with OSHA lockout/tagout requirements—accepts up to three 8 mm padlocks.
Suitable for NEMA 1, 3R, 4, 4X and 12 enclosure applications.
D
H
W
MD Motor Disconnect Switches
MD Motor Disconnect Switch—Non Metallic NEMA 1, 3, 3R, 4, 4X and 12
Enclosure ■◆
Amperes Catalogue
Number
Maximum Horse Power Ratings
Height
(in.)
Width
(in.)
Depth
(in.)
Three Phase Vac
220–240 440–480 600
30 MD3304X 7.5 20 25 6.38 3.9 4.37
60 MD3604X 20 40 40 8.27 4.94 4.37
MD Motor Disconnect Accessories
Cat. No. Description
MDSAN20 2 Normally open auxiliary contact module
MDSAN11 1 normally open and 1 normally closed auxiliary contact module
MDS30P 30 Amp Add on power pole
DE2_P01-17.fm Page 14 Monday, April 28, 2014 2:58 AM
DE2-15
DE2 SAFETY SWITCHES
Safety Switches
04/14
Heavy Duty
RCD Switches
The Schneider Electric 30 AMP RCD Safety Switch is a cost effective commercial disconnect, perfect for use in outdoor HVAC (Heating Ventilation and Air
Conditioning), Air Handling and Air Compressor applications.
The RCD line provides a compact, yet easy to work in EEMAC 3R painted steel enclosure.
Two sets of 1/2-3/4" combination knockouts are provided on the bottom and the back of the switch. The switch mechanism features front accessible terminals
for easy installation.
The RCD can be padlocked in the OFF position and provision only is made for padlocking in the ON position. All exposed hardware is rustproof stainless steel.
RCD NEMA 3R Switches
Front Accessible Terminals
Foolproof Mechanism Installation
Compact Design
Flush Backwall
1/2 - 3/4" Knockouts
Stainless Steel Hardware
EEMAC 3R Non-Fused Weatherproof Switches (600V Maximum)
Poles Amp
Rating Cat. No.
Dimensions – inches (mm) Max. HP Rating
Replacement Mech
Cat. No.
HWD
Height
(with handle) 120 VAC 240 VAC 480 VAC 600 VAC
2 30 RCD5326
8 3/4 (222) 4 1/2 (114) 3 1/4 (83) 9 3/8 (238)
2 5 10 15
3 30 RCD5336 3 7.5 15 20
2 60 RCD5626 - 10 15 20 RCD60002FW
3 60 RCD5636 - 10 25 30 RCD60003FW
DE2_P01-17.fm Page 15 Monday, April 28, 2014 2:58 AM
DE2-16
Safety Switches
DE2 SAFETY SWITCHES
04/14
Heavy Duty Receptacle Switches
Single Throw
600 Volt, 3-Pole
Type 3R/12 switches are suitable for Type 3R application by removing the drainscrew from bottom endwall.
Interlocking linkage between receptacle and switch mechanism prevents the insertion or removal of the plug while the switch is in the “ON” position, or the insertion of a plug other than
specified. Interlocking linkage also prevents the switch from being thrown into the “ON” position while the plug is removed.
“Ser.” denotes the Series of the device. Please refer to this column when selecting accessories.
Fusible switches are suitable for use as service equipment.
Type 3R/12, 4/4X are supplied with viewing window standard.
.
Receptacle Switches with Appleton Receptacles
3-Pole
HP Ratings - 3ø r
Fuse Type
Provision Type 3R/12 Type 4/4X
(Stainless Steel)
Use with
Appleton Plug
480 Vac 600 Vac 250 Vdc
System Amps Ser. Ser. Std. Max. Std. Max. Std. Max.
Fusible
30 H F7 H361AWAVW F7 H361DSWAVW ACP3034BC 5 15 7 1/2 20 5 -
60 H F7 H362AWAVW F7 H362DSWAVW ACP6034BC 15 30 15 50 10 -
100 H F7 H363AWAVW F7 H363DSWAVW ACP1034CD 25 60 30 75 20 -
Non-Fusible
30 - F7 HU361AWAVW F7 HU361DSWAVW ACP3034BC - 20 - 30 - 5
60 - F7 HU362AWAVW F7 HU362DSWAVW ACP6034BC - 50 - 60 - 10
100 - F7 HU363AWAVW F7 HU363DSWAVW ACP1034CD - 75 - 100 - 20
Classified for use with Crouse-Hinds Arktite® plugs
Receptacle Switches with Crouse-Hinds Receptacles
3-Pole
HP Rating - 3ø r
Fuse Type
Provision Type 3R/12 Type 4/4X
(Stainless Steel)
Use with
Crouse-Hinds Plug
480 Vac 600 Vac
System Amps Ser. Ser. Std. Max. Std. Max.
Fusible
30 J F7 CH361AWC F7 CH361DSWC APJ3485 5 15 7 1/2 20
60 J F7 CH362AWC F7 CH362DSWC APJ6485 15 30 15 50
100 J F7 CH363AWC F7 CH363DSWC APJ10487 - 60 - 75
Non-Fusible
30 - F7 CHU361AWC F7 CHU361DSWC APJ3485 - 20 - 30
60 - F7 CHU362AWC F7 CHU362DSWC APJ6485 - 50 - 60
100 - F7 CHU363AWC F7 CHU363DSWC APJ10487 - 60 - 75
Approximate Dimensions - Appleton Type 3R/12
Appleton Receptacle
Crouse-Hinds Receptacle
Ampere
Rating
Height (H)
in./mm
Width (W)
in./mm
W/H
in./mm
Depth (D)
in./mm
H/R
in./mm
30 16.50/419 9.00/229 10.50/267 7.00/178 22.25/565
60 16.50/419 9.00/229 10.50/267 7.00/178 22.25/565
100 20.50/521 9.00/229 10.50/267 7.00/178 26.25/667
Approximate Dimensions - Appleton Type 4/4X (Stainless Steel)
Ampere
Rating
Height (H)
in./mm
Width (W)
in./mm
W/H
in./mm
Depth (D)
in./mm
H/R
in./mm
30 16.87/428 8.92/227 10.81/275 5.11/130 23.00/584
60 16.87/428 8.92/227 10.81/275 5.11/130 23.00/584
100 20.82/529 9.36/238 11.25/286 6.97/177 28.00/711
Approximate Dimensions - Crouse-Hinds Type 3R/12
Ampere
Rating
Height (H)
in./mm
Width (W)
in./mm
W/H
in./mm
Depth (D)
in./mm
H/R
in./mm
30 16.50/419 9.00/229 10.50/267 7.00/178 23.25/591
60 16.50/419 9.00/229 10.50/267 7.00/178 23.25/591
100 20.50/521 9.00/229 10.50/267 7.00/178 28.05/712
Approximate Dimensions - Crouse-Hinds Type 4/4X (Stainless Steel)
Ampere
Rating
Height (H)
in./mm
Width (W)
in./mm
W/H
in./mm
Depth (D)
in./mm
H/R
in./mm
30 16.87/428 8.92/227 10.81/275 5.11/130 23.00/584
60 16.87/428 8.92/227 10.81/275 5.11/130 23.00/584
100 20.82/529 9.36/238 11.25/286 6.97/177 28.00/711
D
H
H/R
OFF
ON
W
W/H
Application Information
Dimensions are approximate only. Do not use for
construction.
For terminal lug data refer to page DE2-25.
rHP Ratings:
- Standard - using fast acting one time fuses
- Maximum - using time delay fuses
- refer to latest design series only
Heavy Duty Switches have Quick-Make / Quick-Break
operating mechanisms Load-Make / Load-Break rated.
For information regarding accessories and optional
features, see pages DE2-22 to DE2-26.
For more information consult Schneider Electric.
lThe CSA certified short-circuit current rating for Square D
Heavy Duty, Non Fused switches is based on the switch
being used in conjunction with fuses. Evaluation of not
fused switches in conjunction with molded case circuit
breakers has not been performed. If a CSA certified short-
circuit current rating is required, this not fused switch must
be replaced with a SQUARE D Heavy Duty Fusible safety
switch equipped with the appropriate class and size fus-
ing. Consult the wiring diagram of the switch to verify the
CSA certified short-circuit current rating.
Short Circuit Current Ratings l i
RMS Symmetrical k Amps
Fuse Class
Voltage H J L R
600 Vac 10 200 200 200
i Apply to AC only.
DE2_P01-17.fm Page 16 Monday, April 28, 2014 2:58 AM
DE2-17
DE2 SAFETY SWITCHES
Safety Switches
04/14
Heavy Duty
1000 Vdc Photovoltaic Disconnect Switch
Order EIK1PV for single contact field-installed kit.
Order EIK2PV for double contact field-installed kit.
Accommodates (2) 250 max Cu or (1) 1/0 max Cu wiring; Order SN20CPV for
field-installed kit.
Required when adding surge arrestors. Accommodates (2) 6-300 Cu/Al
wiring; One lug for the line connection and one for the surge arrestor
connection.
Order AL20DTF for field installable kit.
Order REHGND KIT for field installable kit.
sTerminal blocks standard with 3 pole switches; accommodates (2) 1/0 max
Al/Cu or (2) 6 max Al/Cu wiring.
Put over 100 years of Schneider Electric’s experience as a global specialist in energy management to work on your photovoltaic (PV)
project. The Square D 1000 Vdc disconnect switch is the perfect solution for your 1000 Vdc PV disconnect applications. It is compact
and available in both a 100 and 200 amp non-fusible versions. UL98-B, IEC 60947-1 and 3 certified (file 136861).
Extended Life Expectancy
Exceeds IEC 60947-3 mechanical endurance
requirements by factor of 18
Exceeds IEC 60947-1 electrical endurance
requirements by factor of 10
Exceeds NEMA KS-1 mechanical endurance
requirements by factor of 3.
Easy to Install
Preconfigured solar solution
Familiar enclosed safety switch design
Suitable for both grounded and ungrounded PV
Designed for Harsh PV Environments
NEMA Type 3 and IP63 enclosure
Resists windblown dirt/dust
Exceeds NEMA Type 1, 3R and 12
Operating range of -37°C to 50°C
Specially designed PV paint reduces solar gain by 40% over
standard grey enclosures
1000 Vdc Photovoltaic Heavy Duty Disconnect Switch and Accessories
System
NEMA 1, 3R, 12, 3
and IP63
Factory Installed Accessories
Electrical Interlock
Single Contact
Electrical Interlock
Two Contacts
Viewing
Windows
Terminal
Blocks
(Copper)
Surge
Arrestor
Connector
3 Wire
Ground
Lug
Amp Cat. No. No. Suffix No. Suffix No. Suffix No. Suffix No. Suffix No. Suffix
3 Pole Groundeds
100 REHU393IP EI1 EI2 VW TBC SA GL
200 REHU394IP EI1 EI2 VW TBC SA GL
4 Pole Ungrounded
100 REHU493IP EI1 EI2 VW SA GL
200 REHU494IP EI1 EI2 VW SA GL
PE
Ligne
Connecteur
Connecteur
Charge
Borne de mise à la terre
3 pôles (système mis à la terre)
PE
Ligne
Connecteur
Ligne
Borne de mise à la terre
4 pôles (système non mis à la terre)
Charge
Charge
100 A Enclosed Switch Dimensions (inches) 200 A Enclosed Switch Dimensions (inches)
DE2_P01-17.fm Page 17 Monday, April 28, 2014 2:58 AM
DE2-18
Safety Switches
DE2 SAFETY SWITCHES
04/14
Double Throw
Double Throw - Fusible & Non-Fusible
240Vac, 2-Pole & 3-Pole
NFor switching dc, use outside two poles.
#Use outer switching poles.
MMaximum rating.
LNot available with padlock on provision.
m240 Vac only.
Type 3R/12
Horsepower Ratings r
System Amps Ser.Type 1 Ser. Type 3R Ser. Type 4/4X Ser. 240 Vac
250 Vdc
N
Stainless Steel Std. Std. Max. Max.
3Ø 1Ø 3Ø
2-Pole, Fusible, 240Vac - 250Vdc
30 - - - - - - - - - - - - -
60 - - - - - - - - - - - - -
100 F5 DT223 F5 DT223RB - - - - 7.5 15 15 30 20
2-Pole, Non-Fusible, 240Vac
30 T4 C92251 L---- -
200 USE 3- POLE 600V DEVICES
400 A1 82255 A1 82255R - - A1 H82255 - - - - -
2-Pole, Non-Fusible, 240Vac - 250Vdc
60 F5 DTU222 USE 3-POLE 600V DEVICES. - - 10 - 10 M
100 F5 DTU223 F5 DTU223RB - - - - - - 15 - 20 M
3-Pole, Fusible, 240Vac - 250Vdc
30 F5 DT321 F5 DT321RB - - - - 1.5 #33#7.5 5
60 F5 DT322 F5 DT322RB - - - - 3 #7.5 10 #15 10
100 F5 DT323 F5 DT323RB - - - - 7.5 #15 15 #30 20
3-Pole, Non-Fusible, 240Vac - 250Vdc
30 T4 C92351 Lm------ -----
200 USE 3- POLE 600V DEVICES
400 A1 82355mA1 82355Rm--A1
H82355m---- -
600 A1 DTU326 A1 DTU326R - - - - - 125 - - 50
3-Pole, Non-Fusible, 240Vac - 250Vdc
30 F5 DTU321 USE 3-POLE 600V DEVICES -35#10 5 M
60 F5 DTU322 --10#15 10 M
100 F5 DTU323 F5 DTU323RB - - - - - - 15 #30 20 M
Application Information
For application infromation, see page DE2-19.
DE2_P18-20.fm Page 18 Monday, April 28, 2014 2:51 AM
DE2-19
Safety Switches
DE2 SAFETY SWITCHE
S
04/14
Double Throw
Double Throw - Fusible & Non-Fusible
600 Volt, 2-Pole & 3-Pole
NFor switching dc, use two poles.
MUse outer switching poles.
hUse 75º C #4 Cu or #2 Al conductors only.
$Use 75º C #1 Cu conductors only.
#Type 12 only.
LFor isolation use only.
Fusible switches accept class H fuses as standard.
Fusible switches are suitable for use as service equipment when installed with a neutral kit (page DE2-27).
Horsepower Ratings r
System Amps Ser. Type 1 Ser. Type 3R Ser. Type 4/4X Ser. Type 3R/12 240 Vac 480 Vac 600 Vac DCN
Stainless Steel Std. Max. Std. Max. Std. Max. 250 600
3Ø 3Ø
2-Pole, Fusible,600 Vac
30 - 200A USE 3 WIRE DEVICES FOR 2 POLE APPLICATION
2-Pole, Non-Fusible, 600 Vac
30 - 600A USE 3 WIRE DEVICES FOR 2 POLE APPLICATION
3-Pole, Fusible, 600 Vac - 600 Vdc
30 F5 DT361 F5 DT361RB - - - - - - 5 15 7.5 20 5 15
60 F5 DT362 F5 DT362RB - - - - - - 15 30 15 50 - 30
100 F5 DT363 F5 DT363RB - - - - - - 25 60 30 75 - 50
3-Pole, Non-Fusible, 600 Vac - 600 Vdc
M
3Ø 1Ø
M
3Ø 1Ø
M
30 F5 DTU361 F5 DTU361RB - - - - 5 10 7.5 20 10 30 5 15
60 F5 DTU362 F5 DTU362RB F6 DTU362DS F6 DTU362AWK 10 20 25 50 30 60h10 30
100 F5 DTU363 F5 DTU363RB F6 DTU363DS F6 DTU363AWK 20 40$40 75$40 75$20 50
3-Pole, Non-Fusible, 600 Vac - 250 Vdc
200 E1 C82344 LE1 C82344RB LE1 C82344DS LE1 CH82344 L# --------
400 A1 82345 A1 82345R A1 82345DS A1 H82345 - - - - - - - -
600 A1 DTU366 A1 DTU366R - - A1 DTU366AWK#- 125 - 250 - 350 50 -
Application Information
DT & DTU (series F, A), 82,000 Switches have Quick-Make /
Quick-Break mechanisms, Load-Make / Load-Break rated.
92,000 Lines of Double Throw Switches are not Load-Make
/ Load-Break rated, for isolation use only.
For information regarding accessories and optional
features, see page DE2-27.
rHP Rating: Standard value when using fast acting one time
fuses. Max. value when using dual element time delay fuse.
For more information, consult Schneider Electric.
RMS Symmetrical k Amps i
Switch
Type
Ampere
Rating
Voltage
Rating
Fuse Class
HKR J
Type DT
Series F 30-100A 240V or 600V 10 10 200 200
Type DTU
Series F ,30-100A 240V or 600V 10 10 200 200
Type DTU
Series A1 600A 240V or 600V 10 10 100 100
Type 82000 200-400A 240V
600V
10
10
10
10
100
-
100
-
Type 92000 30A 240V 10 10 - -
iRating applies to AC only. Short circuit cur-
rent rating for Non-Fusible switches is based
on the switch being used in conjunction with
the corresponding fuse type. Evaluation of
Non-Fusible swtches in conjunction with
molded case circuit breakershas not been
peformed.
,The DTU361 and DTU361RB are also
suitable for use on a circuit capable of
delivering not more than:
(A) 18,000 rms summetrical A, 600 Vac
DE2_P18-20.fm Page 19 Monday, April 28, 2014 2:51 AM
DE2-20
Safety Switches
DE2 SAFETY SWITCHES
04/14
Double Throw
Double Throw - Non-Fusible
240Volt&600Volt,4&6Pole(Not Suitable for Service Equipment)
System Amps Ser. Type 1 Ser. Type 3R Type 3R/12
Horsepower Ratings r
Ser. Type 4/4X Ser. 240 Vac 480 Vac 600 Vac DC
Stainless Steel Std. Max. Std. Max. Std. Max. 250 600
3Ø 3Ø 3Ø
4-Pole, Non-Fusible, 240 Vac - 250Vdc
30 T4 C92451m- - - - - - --------
60 USE 4 - POLE 600 V DEVICE
100
200 E3 82454 E3 82454R - - - - --------
400 A1 82455mA1 82455Rm--A1
H82455m--------
600 A1 DTU426 A1 DTU426R - - - - 125 - 250 - 350 - 50 -
4-Pole, Non-Fusible, 600 Vac - 600 Vdc
3Ø 2Ø 3Ø
30- - - - - - - - ------
60 F5 DTU462 F6 DTU462AWK F6 DTU462DS F6 DTU462AWK 20 20 40 50 50 60 10 30
100 F5 DTU463 F6 DTU463AWK F6 DTU463DS F6 DTU463AWK 30 40 50 75 50 75 20 30
4-Pole, Non-Fusible, 600 Vac - 250Vdc
200 E3 82444 E3 82444R E3 82444DS - - - - - - - - - -
400 A1 82445 A1 82445R - - A1 H82445 - - - - - - - -
600 A1 DTU466 A1 DTU466R - - - - 125 - 250 - 350 - 50 -
6-Pole, Non-Fusible, 600 Vac - 600 Vdc
3Ø 1Ø 3Ø
30- - - - - - - - ------
60 - - - - - - F6 DTU662AWK - 20 - 50 - 60 10 30
100 - - - - - - F6 DTU663AWK - 40 - 75 - 75 20 50
Application Information
For application information, see page DE2-19.
m - 240 Vac only
DE2_P18-20.fm Page 20 Monday, April 28, 2014 2:51 AM
DE2-21
DE2 SAFETY SWITCHES
Safety Switches
04/14
Double Throw
Technical Data
Approximate Dimensions
30–100 A Type DT, DTU (Series F)—Approximate Dimensions
Catalogue
Number Series H W W/H D
IN mm IN mm IN mm IN mm
DT321 F5 38.42 976 10.25 260 11.96 304 6.93 176
DT361 F5 38.42 976 10.25 260 11.96 304 6.93 176
DT322 F5 38.42 976 10.25 260 11.96 304 6.93 176
DT362 F5 38.42 976 10.25 260 11.96 304 6.93 176
DT321RB F5 38.64 982 10.25 260 11.96 304 6.93 176
DT361RB F5 38.64 982 10.25 260 11.96 304 6.93 176
DT322RB F5 38.64 982 10.25 260 11.96 304 6.93 176
DT362RB F5 38.64 982 10.25 260 11.96 304 6.93 176
DT223 F5 38.42 976 10.25 260 11.96 304 6.93 176
DT323 F5 38.42 976 10.25 260 11.96 304 6.93 176
DT363 F5 38.42 976 10.25 260 11.96 304 6.93 176
DT223RB F5 38.64 982 10.25 260 11.96 304 6.93 176
DT323RB F5 38.64 982 10.25 260 11.96 304 6.93 176
DT363RB F5 38.64 982 10.25 260 11.96 304 6.93 176
DTU321 F5 29.94 760 10.25 260 11.96 304 6.93 176
DTU361 F5 29.94 760 10.25 260 11.96 304 6.93 176
DTU222 F5 29.94 760 10.25 260 11.96 304 6.93 176
DTU322 F5 29.94 760 10.25 260 11.96 304 6.93 176
DTU362 F5 29.94 760 10.25 260 11.96 304 6.93 176
DTU223 F5 29.94 760 10.25 260 11.96 304 6.93 176
DTU323 F5 29.94 760 10.25 260 11.96 304 6.93 176
DTU363 F5 29.94 760 10.25 260 11.96 304 6.93 176
DTU361RB F5 30.50 775 10.25 260 11.96 304 6.93 176
DTU362RB F5 30.50 775 10.25 260 11.96 304 6.93 176
DTU223RB F5 30.50 775 10.25 260 11.96 304 6.93 176
DTU323RB F5 30.50 775 10.25 260 11.96 304 6.93 176
DTU363RB F5 30.50 775 10.25 260 11.96 304 6.93 176
DTU362AWK F6 30.26 769 10.25 260 11.96 304 7.18 182
DTU363AWK F6 30.26 769 10.25 260 11.96 304 7.18 182
DTU362DS F6 30.30 770 10.25 260 11.96 304 7.18 182
DTU363DS F6 30.30 770 10.25 260 11.96 304 7.18 182
DTU462 F5 30.30 770 15.46 393 17.18 436 7.18 182
DTU463 F5 30.30 770 15.46 393 17.18 436 7.18 182
DTU462AWK F6 30.30 770 15.46 393 17.18 436 7.18 182
DTU662AWK F6 30.30 770 15.46 393 17.18 436 7.18 182
DTU463AWK F6 30.30 770 15.46 393 17.18 436 7.18 182
DTU663AWK F6 30.30 770 15.46 393 17.18 436 7.18 182
DTU462DS F6 30.30 770 15.46 393 17.18 436 7.18 182
DTU463DS F6 30.30 770 15.46 393 17.18 436 7.18 182
30 A Type C92,000 — Approximate Dimensions
Catalogue
Number Series H W W/H D
IN mm IN mm IN mm IN mm
C92251 T4 11.38 289 10.13 257 13.50 343 6.13 156
C92351 T4 11.38 289 10.13 257 13.50 343 6.13 156
C92451 T4 11.38 289 10.13 257 13.50 343 6.13 156
200 A 3P Type C82,000 — Approximate Dimensions
Catalogue
Number Series H W W/H D
IN mm IN mm IN mm IN mm
C82344 E1 30.88 784 20.00 508 23.88 607 11.75 298
C82344RB E1 30.88 784 20.00 508 23.88 607 11.75 298
C82344DS E1 32.90 836 19.90 505 22.90 582 10.30 262
CH82344 E1 32.90 836 19.90 505 22.90 582 10.30 262
200 A 4PType 82,000 — Approximate Dimensions
Catalogue
Number Series H W W/H D
IN mm IN mm IN mm IN mm
82454 E3 38.00 965 29.62 752 33.02 839 10.63 270
82454R E3 39.00 991 30.21 767 33.02 839 10.63 270
82444 E3 38.00 965 29.62 752 33.02 839 10.63 270
82444R E3 39.00 991 30.21 767 33.02 839 10.63 270
600 A Type DTU (Series A01) — Approximate Dimensions
Catalogue
Number Series H W W/H D
IN mm IN mm IN mm IN mm
DTU326 A1 63.31 1608.07 23.66 600.96 24.46 621.28 8.88 225.55
DTU326R A1 63.76 1619.50 23.66 600.96 24.46 621.28 8.88 225.55
DTU426 A1 63.31 1608.07 27.00 685.80 27.80 706.12 8.88 225.55
DTU426R A1 63.76 1619.50 27.00 685.80 27.80 706.12 8.88 225.55
DTU366 A1 63.31 1608.07 23.66 600.96 24.46 621.28 8.88 225.55
DTU366AWK A1 63.76 1619.50 23.66 600.96 24.46 621.28 8.88 225.55
DTU366R A1 63.76 1619.50 23.66 600.96 24.46 621.28 8.88 225.55
DTU466 A1 63.31 1608.07 27.00 685.80 27.80 706.12 8.88 225.55
DTU466R A1 63.76 1619.50 27.00 685.80 27.80 706.12 8.88 225.55
DT, DTU Series F
Type 1 Enclosure
DT, DTU Series F
Type 3R Enclosure
DT, DTU Series F
Type 4, 4X, 5 and 12 Enclosure
400 A Type 82,000 (Series A01) — Approx. Dimensions
Catalogue
Number Series H W W/H D
IN mm IN mm IN mm IN mm
82255 A1 38.50 977.90 26.10 662.94 29.51 749.55 10.63 270.00
82255R A1 39.00 990.60 26.62 676.15 30.02 762.51 10.63 270.00
82345 A1 38.50 977.90 26.10 662.94 29.51 749.55 10.63 270.00
82345DS A1 39.00 990.60 26.62 676.15 30.02 762.51 10.63 270.00
82345R A1 39.00 990.60 26.62 676.15 30.02 762.51 10.63 270.00
82355 A1 38.50 977.90 26.10 662.94 29.51 749.55 10.63 270.00
82355R A1 39.00 990.60 26.62 676.15 30.02 762.51 10.63 270.00
82445 A1 38.50 977.90 30.10 764.54 33.50 850.90 10.63 270.00
82445R A1 39.00 990.60 30.21 767.33 33.61 853.69 10.63 270.00
82455 A1 38.50 977.90 30.10 764.54 33.50 850.90 10.63 270.00
82455R A1 39.00 990.60 30.21 767.33 33.61 853.69 10.63 270.00
H82255 A1 39.00 990.60 26.62 676.15 30.02 762.51 10.63 270.00
H82345 A1 39.00 990.60 26.62 676.15 30.02 762.51 10.63 270.00
H82355 A1 39.00 990.60 26.62 676.15 30.02 762.51 10.63 270.00
H82445 A1 39.00 990.60 30.21 767.33 33.61 853.69 10.63 270.00
H82455 A1 39.00 990.60 30.21 767.33 33.61 853.69 10.63 270.00
DE2_P21-30.fm Page 21 Monday, April 28, 2014 2:55 AM
DE2-22
Safety Switches
DE2 SAFETY SWITCHES
04/14
Application Information
For more information, consult Schneider Electric.
Heavy Duty
Accessories
Fuse Provisions
Class H Fuse Provisions:
Fusible 30 - 600A Heavy Duty Safety Switches accept Class H fuses as standard
except where noted below.
Provisions for installing Class H fuses are included in switches supplied with
Class J fuses as standard.
Conversion to Class H fuse spacing requires relocating the load side fuse base
assembly from the standard J fuse location to an alternate position as marked in
the enclosure. With Class H fuses installed, the switch is CSA Certified for use on
systems with up to 10,000 RMS Symmetrical Amperes available fault current.
Class J Fuse Provisions:
Fusible Square D 30 through 200 Ampere, 600 Volt, 3-Pole Heavy Duty Safety
Switches accept Class J fuses as standard.Provisions for installing Class J
fuses are included in 400 Ampere 600 Volt, and 100 through 400 Ampere 240
Volt, fusible, Heavy Duty Safety Switches. Conversion to Class J fuse spacing re-
quires relocating the load side fuse base assembly from the standard H fuse lo-
cation to an alternate position as marked in the enclosure. With J fuses installed,
the switch is CSA Certified for use on systems with up to 200,000 RMS Symmet-
rical Amperes available fault current. Switches rated 600 Ampere, 240V or 600V,
require the addition of an adapter kit, H600J. One kit per 3-pole switch.
 Including switches with Crouse Hinds Receptacles.
Class L Fuse Provisions:
Fusible 800A and 1200A Heavy Duty Safety Switches use Class L bolt-on fuses
and are CSA Certified for use on systems with up to 200,000 RMS Symmetrical
Amperes at 600Vac maximum.
English Electric Fuse Provisions (HRCII-C):
English Electric Fuse Provisions are available factory installed only on E-Series
and F-Series Safety Switches. Available for all 30 - 200 A, 600V, 3-Pole Safety
Switches. HRCII-C Fuse kits are CSA Certified.
To order, add “HE’’ suffix to standard catalogue number.
Example: CH361HE
Fuse Puller Kits
Kit consists of three fuse pullers and can be installed in all E-Series and F-Series
Safety Switches, 30 - 100A. Fuse pullers supplied as standard equipment on
Type 3R/12, Type 4/4X stainless steel, Type 4X Fiberglass-reinforced Polyester
switches through 100 Ampere. Fuse Puller Kits are CSA Certified, and available
for factory or field installation.
For factory installation, add “FP” suffix to standard catalogue number.
Example: CH361FP
s 30A, 4- and 6-pole, Series F5 use FPK0610.
H362AWAVW & CH362AWC, use FPK0610 Fuse Puller Kit.
Class R Fuse Provisions:
The rejection kit, when installed, rejects all but Class
R fuses. With the installation of the rejection kit and
Class R fuses, the switch is CSA Certified for use on
systems with up to 200,000 RMS Symmetrical Am-
peres available fault current.
CSA Certified Rejection kits are available for E-Series
and F-Series Safety Switches. Kits are available for
factory or field installation.
For factory installation, add “CLR’’ suffix to standard
catalogue number.
Example: CH361CLR
CSA Certified Maximum Short Circuit Current Ratings—AC
only
NOTE: Consult the wiring diagram of the switch to verify the CSA
certified short circuit current rating.
On 600 V, 200 A switches, 100,000 A max. on corner grounded delta when
protected by Class J or R fuses.
Non-Fusible Safety Switches
Any brand of circuit breaker or fuse not exceeding the ampere rating of the switch
may be used in conjunction with an non-fused safety switch when there is up to
10 kA short circuit current available. (See table below.)
Above 10, kA—When applied on systems with greater than 10 kA short circuit
current available, the CSA certified short circuit current rating for Square D non-
fused switches is based upon the switch being used in conjunction with fuses or
Square D circuit breakers.
Heavy Duty Safety Switches 30A 60A 100A 200A 400A 600A
2-3-Pole, 240V H H H H H H
3-Pole, 600V JJJJHH
4-Pole, 600V H H H H H H
6-Pole, 600V --- --- H H --- ---
316 Grade Stainless steel H H H H --- ---
Polyester Enclosures H H H H --- ---
c/w Appleton Receptacles H H H --- --- ---
c/w Crouse-Hinds Receptacles JJJ--- --- ---
MD50 Motor Disconnect J J --- --- --- ---
Double Throw H H H --- --- ---
Switch Ampere
Rating Series Number Fuse Puller Kit
Catalogue Number
30 F1, F5-F7 FPK03s
30 F3 FPK0610
60 F1, F2, F3, F5-F7 (600 V) FPK0610
60F4, F5-F7 (240 V) FPK03
100 F2-F5 FPK0610
Class R Fuse Kits - 240 Volt (one kit per 3-pole switch)
Switch Ampere
Rating
Series Number Class R Fuse Kit
Catalogue Number
30 F5-F7 RFK03L
60 F1, F2, F3 RFK06
60 F4-F7 RFK03H
100 F2-F7 RFK10
200 F5, F6 HRK1020
400-600 E HRK4060
Class R Fuse Kits - 600 Volts (one kit per 3-pole switch)
Switch Ampere
Rating
Series Number Class R Fuse Kit
Catalogue Number
30 F1, F5-F7 RFK03H
30 F3 RFK06
60 F1-F7 RFK06H
100 F2-F7 RFK10
200 F5, F6 HRK1020
400-600 E2-E4 HRK4060
The following series - F5-F7 devices use RFK06: H461, H461DS, H461AWK, H361DF,
H361AWAVW and CH361AWC.
Fusible Safety Switches
For the short circuit current rating, refer to the table below.
Heavy Duty
Safety Switch Type Fuse Class Short Circuit
Current Ratings
Fusible H, K 10 kA
R, J, L 200 kA
Non-Fusible Safety Switches
Heavy Duty Safety
Switch Type
Switch Rating
(A) *
Fuse or Circuit Breaker
Type ** 3 Phase
240 Vac 480 Vac 600 Vac
Non-Fusible
Switches
All
Any Brand Circuit Breaker Up to 10 kA
H, K
R, T, J, L 200 kA 200 kA 200 kA
30–100 H*** 65 kA 35 kA 35 kA
30–100 FA 14 kA 14 kA 14 kA
30-100 FH 18 kA 18 kA 18 kA
200 H, J,*** 65 kA 35 kA 35 kA
400 LA 22 kA 22 kA 22kA
400 LH 25 kA 25 kA 25 kA
* Applies to NEMA 1, 3R, 4X stainless, 12 switches.
** Amperage rating of fuse or circuit breaker not to exceed switch amperage rating.
*** All H and J circuit breakers are acceptable, but will only support the noted Short
Circuit Current Rating
DE2_P21-30.fm Page 22 Monday, April 28, 2014 2:55 AM
DE2-23
DE2 SAFETY SWITCHES
Safety Switches
04/14
Heavy Duty
Accessories
For Safety Switches with viewing windows standard, factory modifications are available to have the switch built without the window.
To order, add “WW” to standard catalogue number.
Example: CH361DSWW
Door-mounted Accessories
Push buttons, pilot lights and selector switches are available factory installed in the cover of Type 1, 4/4X, 3R/12, 600V heavy duty safety switches. For more information
please refer to D3110HO0701BP. Voltage indicators are available factory installed in the cover of Type 4/4X, 3R/12, 600V heavy duty safety switches. For more informa-
tion please refer to D3110HO0601BP or contact Schneider Electric.
Solid Neutral Assemblies
Solid Neutral Assemblies for 240 & 600V Safety Switches
Fusible, Heavy Duty Safety Switches are suitable for use as service equipment when installed with a Solid Neutral. Solid Neutrals cannot be installed in 4-Pole, 6-Pole
Safety Switches.
For factory installation, add “N” suffix to standard catalogue number. If catalogue number is suffixed with “RB”, “DS” or “AWK” (enclosure designations), add “N” suffix
before enclosure suffix.
Example: CH361NDS
Viewing Windows
Cover viewing windows are positioned over the blades to allow visual verification of “ON-OFF’’ status. Viewing windows are not available on
Type 7/9, 4X Fiberglass-reinforced Polyester Enclosures. Consult the table below for availability on standard Heavy Duty Safety Switches.
To order optional viewing windows, factory installed and CSA Certified, add “VW’’ suffix to standard catalogue number.
Example: CH365VW
Ampere
Rating
2 and 3-Pole 4 and 6-Pole
Type 1, 3R Type 4/4X Type 3R/12 Type 1, 3R/12
30-200A Optional Standard Standard Optional
400-600A Optional Optional Optional Not Available
800-1200 A Optional ---- Optional ----
Ampere
Rating
Series
#
Catalogue
Number
(AI/Cu)
Terminal Data
AWG/kcmil
Catalogue
Number
(Cu Only)
Terminal Data
AWG/kcmil
30 F1, F5-F6
CSN03 (3)-#2 Max. AI/Cu CSN03C (2)-#6 Max. Cu
60 F4
F5-F6 (240 V)
60 F5-F6 (600 V) CSN0610 (2)-#1/0 Max. AI/Cu
(2)-#6 Max. AI/Cu CSN0610C (2)-#1/0 Max. Cu
(2)-#6 Max. Cu
100 F2-F6 CSN0610 (2)-#1/0 Max. AI/Cu
(2)-#6 Max. AI/Cu CSN0610C (2)-#1/0 Max. Cu
(2)-#6 Max. Cu
200 F5-F6 CSN20 (2)-250 Max. AI/Cu
(1)-#1/0 Max. Al/Cu CSN20C (2)-250 Max. Cu
(1)-#1/0 Max. Cu
400 - 600 E1-E4 CH600SN (4)-750 Max. AI/Cu
(1)-300 AI/Cu CH600SNC
(2)-600 Max. Cu
(2)-350 Max. Cu
(1)-250 Max. Cu
800 E2-E4 H800SNE4 (6)-750 Max. AI/Cu
(2)-350 Max. AI/Cu ---- ----
1200 E2-E4 H1200SNE4 (8)-750 Max. AI/Cu
(2)-350 Max. AI/Cu ---- ----
For 200% neutral, order (2) neutral kits and (1) SN20NI neutral jumper kit. (2) 350 Max. Al/Cu.
Solid Neutral Assemblies for Type 7/9 Enclosed
Moulded Case Switches
Ampere Rating Catalogue Number
30 100SNA
60 100SNA
100 100SNA
200 225SNA
Application Information
For more information, consult Schneider Electric.
For viewing window availability on Double Throw Switches 30-100A Series F, please refer to page DE2-27.
DE2_P21-30.fm Page 23 Monday, April 28, 2014 2:55 AM
DE2-24
Safety Switches
DE2 SAFETY SWITCHES
04/14
Heavy Duty
Accessories
Electrical Auxillary Interlock Kits
Electrical interlocks for Heavy Duty 30-1200 Ampere Safety Switches are avail-
able factory installed or in kit form for field installation. Each kit contains instruc-
tions for proper field mounting. A pivot arm operates from switch mechanism,
breaking the control circuit before the main switch blades break. Electrical inter-
lock kits are CSA Certified.
For factory installation add “EI” or “EI2” suffix to standard catalogue number.
Example: CH361EI
Electrical interlock kit catalogue numbers with -1 suffix indicates one normally
open and one normally closed contact; -2 indicates two normally open and
two normally closed contacts.
Not suitable for Elevator use.
HU461AWK uses EK306-1,2; H461, H461 DS, H461AWK, HU461,
HU461DS, HU661DS, HU661AWK, H361AWAVW, CH361AWC,
CHU361AWA, CHU361AWC use EIK-1,2.
Safety switches complete with voltage monitors use EIK1 or EIK2.
Single pole throw interlock kits are rated 1/2 HP @ 110 and 220Vac.
-1 Suffix utilizes a 9007A01 limit switch.
-2 Suffix utilizes a 9007C03 limit switch.
Elevator Rated Electrical Interlocks*
These interlocks are CSA approved, field installable and can be used in switches
with date codes starting with 06454 (year 2006, week 45, day 4 of week) or later.
* CSA approved for Type 1, 3R, 4/4X & 3R/12 applications
Key Interlock Systems
Factory installed only on Heavy Duty Safety
Switches and Double Throw Safety Switches.
Interlocks are used to prevent the authorized op-
erator from making an unauthorized operation.
Not available on hazardous location devices
(Type 7/9) or fibreglass reinforced polyester (Type
4X).
The Key Interlock System is a simple and easy
method of applying individual key interlock units
and assemblies to the above equipment so as to
require operation in a predetermined sequence.
Before preparation of construction equipment with key interlocks can begin, the
following information must be known:
1. Ultimate user –name and address
2. Key number, ‘SO’ number and item number from lock assemblies on
any existing locks to be interlocked with.
3. Sketch of sequence of operations to be accomplished and name and
phone number of specifying engineer. Confirmation from customer is
required before an order is released for production.
4. Other Square D equipment interlocked – order point, order numbers,
etc. for coordination.
5. Schneider Electric key interlocks will be furnished unless otherwise
specified.
To order, add “KI”, “KI2” or “KIKI” suffix to standard catalogue number. Contact
your local Schneider Electric office for a reference number prior to entering the
order.
Example: CH364KI
KI = 1 lock per switch
KI2 = 1 lock with 2 cylinders per switch
KIKI = 2 separate locks per switch
Lock-On Provisions
Provision for one 3/8 inch hasp padlock is available factory installed on Types 1,
3R, 4/4X stainless steel and 3R/12 switches. This modification will allow the
switch to be locked in the “ON’’ position.
To order, add “SPLO” suffix to standard catalogue number.
Example: CH361SPLO
Lock-Off Guard
Designed for use with safety switches in commercial
and industrial settings, Lock-Off Guard enhances the
reliability of lockout procedures to isolate power in
daily activities and provide an effective way to interrupt
power in an emergency.
The innovative Lock-Off Guard works by covering the
lockout/tag-out opening whenever the switch is in the
“ON” position, preventing a padlock from being
inadvertently inserted into the switch lockplate.
This device is designed to help prevent accidents
caused by an untrained or distracted employee, who
could inadvertently attempt to apply a lockout device
to a switch without turning the switch to “OFF.”
- Installs on Square D 30A to 200A F series Type 1, 3R
and 12 switches in less than 30 seconds.
- Bright red colour reminds users of the seriousness of
lockout/tag-out procedures.
60A 600V and 100A 240V or 600V switches prior to
series F05 require the handle and mechanism be
upgraded in order to install the kits.
Field Installation Kits
Ampere rating Catalogue number
30A LOGK1
60A 240V LOGK1
60A 600V LOGK2
100A and 200A LOGK2
Factory Installed option is available
Order using “LOG” suffix on standard switch catalogue numbers.
Electrical Interlock Kit
Ampere Rating Series Catalogue Number
30 F3
EIK1 or EIK2
60 F1-F3,
F5-F7 (600 V)
30 F1, F5-F7
ElK031 or EIK032
60 F4,
F5-F6 (240 V)
100-200 F2-F7 EIK1 or EIK2
400-1200 E1-E4 EIK40601 or EIK40602
Electrical Interlock Kit
(Type 4X Fiberglass-reinforced Polyester Enclosure)
Ampere
Rating
Catalogue Number
(1NO/1NC)
Catalogue Number
(2NO/2NC)
30A
(F-Series) 9999TC10 9999TC20
60A
(F-Series) 9999TC10 9999TC20
100A
(F-Series) 9999TC10 9999TC20
200A 9999R8 9999R9
Electrical Interlock Contact Ratings
Interlock
Type
AC-50or60Hz DC
Volts Make Break Cont. Volts Make &
Break Cont.
1 NO/1 NC
CONTACT
(-1 Suffix)
120 40A 15A 15A 115 .50A 15A
240 20A 10A 15A 230 .25A 15A
480 10A 6A 15A - - -
600 8A 5A 15A 600 .05A 15A
2 NO/2 NC
CONTACTS
(-2 Suffix)
120 30A 3.0A 10A 115 1.0A 10A
240 15A 1.5A 10A 230 .30A 10A
480 7.5A .75A 10A - - -
600 6.0A .60A 10A 600 .10A 10A
Ampere
Rating
Type 1,
240VAC
Elevator
Interlock
Type 1,
600VAC
Elevator
Interlock
30 CH321N EIK031EV CH361 EIK031EV
60 CH322N EIK031EV CH362 EIK06101EV
100 CH323N EIK06101EV CH363 EIK06101EV
200 CH324N EIK201EV CH364 EIK201EV
Application Information
For more information, consult Schneider Electric.
DE2_P21-30.fm Page 24 Monday, April 28, 2014 2:55 AM
DE2-25
DE2 SAFETY SWITCHES
Safety Switches
04/14
Heavy Duty
Accessories
Rainproof Bolt-On Hubs —
For Use On Type 3R Enclosures
Watertight Hubs —
For Use On Type 4/4X Stainless Steel and Type 3R/12 Enclosures
Two required if grounding conductors are run in parallel.
4 and 6 pole, 30A, F-Series.
Conduit
Size
3/4 1 1 1/4 1 1/2 2 2 1/2 3 3 1/2 4 Closing
Cap
Rainproof
Hub Cat. No. B075 B100 B125 B150 B200 B250 B300 B350 B400 BCAP
Type 3R rainproof enclosures have a bolt-on closing cap factory installed. Order bolt-on hubs separately from
table above.
Hubs thru size 2 1/2 can be directly installed on RB devices. Devices requiring 3" or larger hubs must have holes
cut in the field. Gaskets are provided on 3" and larger hubs.
All hubs are CSA Certified for indoor and rainproof applications.
Conduit Trade Size 1/2 3/4 1 1 1/4 1 1/2 2 2 1/2 3 3 1/2 4
Standard-Zinc
Hub Catalogue Number H050 H075 H100 H125 H150 H200 H250 H300 H350 H400
Chrome Plated
Hub Catalogue Number H050CP H075CP H100CP H125CP H150CP H200CP
Ampere
Rating Series
Catalogue
Number
(AI/Cu)
Terminal Data
AWG/kcmil
Catalogue
Number
(Cu Only)
Terminal Data
AWG/kcmil
30 F1, F5-F7 GTK03 (2)-#12 Cu or
(2)-#10 Al or (1)-#4 Max. AI/Cu GTK03C (1)-#6 Max. Cu
60
F4, F5-F6 (240 V)
F1-F3,
F5-F7 (600 V) GTK0610 (2)-#2/0 Max. AI/Cu GTK0610C (2)-#4 Max. Cu
100 F2-F7
200 F5-F7 PKOGTA2 (2)-#2/0 Max. AI/Cu PKOGTC2 (2)-#4 Max. Cu
400-600 E2-E4 PKOGTA2
(2 Required) (2)-#2/0 Max. AI/Cu PKOGTC3 (4)-#1/0 Max. Cu
800 E2-E4 PKOGTA7 (4)-350 Max. AI/Cu ---- ----
1200 E2-E4 PKOGTA8 (8)-350 Max. AI/Cu ---- ----
Terminal Lug Data
Ampere
Rating
Conductors
Per Phase
Type 1, 3R, 4/4X & 3R/12
Wire Range AWG/Kcmil
Type 7/9
Wire Range AWG/Kcmil
30 1 # 12 - 6 (Al) or # 14 - 6 (Cu)
60 1 # 14 - 3 (Al) or # 14 - 3 (Cu) # 14 - 6 (Cu)
100 1 # 12 - 1/0 (Al) or # 14 - 1/0 (Cu) # 14 - 1 (Cu)
200 1 # 6 - 250 (Al/Cu) # 4 - 300 (Cu)
400 1or
2
# 1/0 - 750 (Al/Cu)or
# 1/0 - 300 (Al/Cu)
600 2 # 3/0 - 500 (Al/Cu)
800 3 # 3/0 - 750 (Al/Cu)
1200 4 # 3/0 - 750 (Al/Cu)
Application Information
For more information, consult Schneider Electric.
“RB Hub”
30-100 Amp switches suitable for 60°C or 75°C conductors. 200-1200 Amp switch suitable for 75°C conductors.
Option sized lugs not available.
HU461AWK - #14 - 6 AWG (Cu).
Max. wire range 600 Al/Cu on Type 4/4X Stainless and Type 12.
Equipment Grounding Kits
Canadian Safety Switches come complete with factory installed Grounding Kits. Additional Grounding Kits are available for field or factory installation in 30-1200 Am-
pere, 240 & 600 Volt Heavy Duty Switches.
For factory installation, add “GL” suffix to standard catalogue number.
Example: CH361GL
DE2_P21-30.fm Page 25 Monday, April 28, 2014 2:55 AM
DE2-26
Safety Switches
DE2 SAFETY SWITCHES
04/14
Heavy Duty
Accessories
Copper Lugs
One kit includes all phase line/load lugs for a 3-pole switch.
Compression Lug Kits (800 and 1200A)
Field installable.
Series E4 800 and 1200A Safety Switches are equipped as standard with
mechanical lugs. Alternate compression lug kits are available for field
installation. Each kit consists of VCEL-075-12H1 VERSA- CRIMP
compression Lugs and lug landing connectors capable of converting line
and loadside of one switch pole or neutral.
CSA certified.
Order one field - installable kit per pole or neutral.
Example: 3-pole, 3 wire requires 3 kits; 3-pole, 4 wire requires 4 kits.
For factory installation, add “LK” suffix to standard catalogue number.
Example: CH367LK
Switch Lubricant
Catalogue Number SWLUB is a field maintenance lubricant for servicing blade/
jaw components in safety switches, 600V and below. SWLUB consists of one 5.3
ounce of BJ20 High Performance Synthetic Grease by Dow Corning®, which has
an operating temperature range from -45° to 180° Celsius.
Square D Grey Paint
Phenolic Legend Plates
Available engraved and mounted on all Heavy Duty Safety Switches except Type
7/9. Legend engraved in 1/4 inch high white letters on black background. Cus-
tomer must provide legend.
To order, add “NP” suffix to standard catalogue number.
Example: CH361NP(Pump)
Special Paint
CSA Certified Heavy Duty Switches are available painted with special safety co-
lours. Special colours available are safety red, safety orange, safety yellow, safety
green, safety blue, radiant purple, black and white. The special epoxy chemical
resistant finish paint is applied over our standard grey finish.
A minimum quantity of 10 is required.
Order by description.
Example: CH361SP
Low Temperature Grease
Square D Safety Switches are designed for use between the operating tempera-
tures of -30° to 40° Celsius. For applications where temperatures may range to
values below standard operating temperatures, a special low temperature grease
can be applied in the initial manufacture of the Safety Switch. This special grease
will allow for applications where temperatures may range to -50° Celsius.
To order, add “LTG” suffix to standard catalogue number.
Example: CH361LTG
Internal Barrier Kits
These barriers provide added protection when a switch door is open.
cUL recognized components.
Heavy Duty safety switches are supplied
standard with Al lugs, which accept both
Cu and Al wires.
For factory installation of copper only lugs add
“SLC” suffix to standard catalogue number.
CSA Certified.
Example: CH361SLC
For field installation of copper only lug kits, order
kits below.
Kits
Switch
Amperage
Lug Kit
Catalogue Number
30 CL0306F
60 CL0306F
100 CL10F
200 CL20F
400 CL40F
600 CL60F
800 ----
1200 ----
Switch
Amperage
Lug Kit
Catalogue Number
Compression Lug(VCEL-075-12H1)
Wire Size
800 H8LKE2 500-750 Kcmil(Al)
or
500 Kcmil(Cu)
1200 H12LKE2
Description Catalogue Number
Field Maintenance Lubricant SWLUB
Description Catalogue Number
ASA 49 Aerosol Paint Can W469X83
Internal Barrier Kits for 30-200A HDSS
Catalogue
Number Description
Switch Ampere
Application (F Series
only)
SS03 Interior Barrier for
30A Safety Switch
240Vac, 600Vac–30A
240Vac–60A
SS06 Interior Barrier for
60A Safety Switch 600Vac–60A
SS10 Interior Barrier for
100A Safety Switch 240Vac, 600Vac–100A
SS20 Interior Barrier for
200A Safety Switch 240Vac, 600Vac–200A
Requires arc shield on 240V switches be changed to 600V arc
suppressor. Arc suppressor must be purchased separately.
Internal Barrier Kits for 800-1200A HDSS
Catalogue
Number Description
SS80120LI Additional line barrier for 800-1200A, 600V
Series E04 Heavy Duty Safety Switch
SS80120LO Additional load barrier for 800-1200A, 600V
Series E04 Heavy Duty Safety Switch
Application Information
For more information, consult Schneider Electric.
Dow Coming® is a Registered Trademark of Dow Corning Corporation.
Al/Cu To Cu only
DE2_P21-30.fm Page 26 Monday, April 28, 2014 2:55 AM
DE2-27
DE2 SAFETY SWITCHES
Safety Switches
04/14
Double Throw Types 82,000, 92,000 and DTU (A-Series)
Accessories
Electrical Interlocks
Electrical interlocks for Double Throw Safety Switches are available in kit form for
field installation only.
Electrical Interlock EK200DTU2 Contact Ratings
Single pole throw interlock kits are rated 1/2 HP @ 100 and 220Vac.
Solid Neutral Assemblies
Solid Neutrals are available for field installation only.
p200-600 A switches suitable for 75° C conductors.
r30 A switches suitable for 60° C or 75° C conductors.
Lock-On Provisions
Lock-on provisions are standard on all 82,000 and 92,000 Line Double Throw
Safety Switches.
Equipment Grounding Kits
Key Interlock Systems
For factory installed Key Interlocks refer to Page DE2-23.
Phenolic Legend Plate
For factory installed Legend Plates, refer to DE2-25.
Viewing Windows
Not available.
Ampere Rating Catalogue Number
30 Series T4 N/A
C82344 EK200DTU2
200 4P Series E EK400DTU2
400 Series A EK400DTU2
600 Series A DS200EK2D
Interlock
Type
AC-50or60Hz DC
Volts Make Break Cont. Volts Make &
Break
Cont.
2 NO/2 NC
CONTACTS
(-2 Suffix)
120 30A 3.0A 10A 115 1.0A 10A
240 15A 1.5A 10A 230 .30A 10A
480 7.5A .75A 10A - - -
600 6.0A .60A 10A 600 .10A 10A
Ampere Rating Catalogue Number Terminal Data AWG/Kcmil
30 Series T4 DT30SN #14-8 Cu/Al
200 3P Series E 225SNA #6-300 Cu/Al
200 4P Series E DT200N #4-250 Cu/Al
400 Series A DT400N (1) #4-600 Cu/Al
(2) #1/0-250 Cu/Al
600 Series A DT600NKD 250-500 Cu/Al
Ampere Rating Catalogue Number Terminal Data
AWG/kcmil
30A Type 92,000 DT30SG (4) #14-4 Cu/Al
200A
Type 82,000 DT100SG (3) #14-1/0 Cu/Al
400A
Type 82,000
PKOGTA2
(2 Required)
(4) #10-2/0 Cu or
(4) #6-2/0 Al
600A
Type DTU DS468GKD #6-250
Application Information
For more information, consult Schneider Electric.
Terminal Lug Data for Type 82,000, 92,000, and DTU
(Series A) p
Ampere Rating
Wires
per
Phase
Wire Range
AWG/kcmil
Al/Cu
30 A (Series T4) r1 #14-8 (Al)
200 1 #6–300
400 1 or 2 1/0 - 600 or 1/0 - 300 Al/Cu
600 2 250 - 500
DE2_P21-30.fm Page 27 Monday, April 28, 2014 2:55 AM
DE2-28
Safety Switches
DE2 SAFETY SWITCHES
04/14
Double Throw Types DT, DTU (F-Series)
Accessories
Electrical Interlocks
Electrical interlocks for Double Throw Safety Switches are available in kit form for
field installation. Each kit contains instructions for proper field mounting. Electri-
cal interlock kits are furnished with 2NO/2NC contacts and are installed in both
“ON” positions, when factory installed.
30-100 A Type DT, DTU (Series F) switches contain (2) separate switching
mechanisms. Each mechanism will accept an electrical interlock. Some applica-
tions may therefore require (2) electrical interlocks.
For factory installation, add “EI” suffix to standard catalogue number.
Example: DTU362EI
Solid Neutral Assemblies
Solid Neutrals are available for field installation on two and three pole Switches.
Fuse Puller
Kit consists of three fuse pullers and can be installed in all double throw switches.
Lock-On Provisions
Lock-on provisions are standard on all 30-100 A Type DT, DTU (series F) Double
Throw Safety Switches.
Equipment Grounding Kits
Key Interlock Systems
For factory installed Key Interlocks refer to Page DE2-23.
Phenolic Legend Plate
For factory installed Legend Plates, refer to DE2-25.
Class R Fuse Provisions
Viewing Windows
To order optional viewing windows factory installed add “VW” suffix to standard
catalogue number.
Example: DTU362AWKVW.
Ampere Rating Catalogue Number
30 - 100A EIK1 or EIK2
Ampere Rating Catalogue Number Terminal Data AWG
30 - 100 SN0310 (1) #14-1/0 (Cu/Al)
30 - 100 SN0310C (1) #14-1/0 (Cu)
Ampere Rating Catalogue Number
30 - 100A series F FPK0610
Ampere Rating Catalogue Number
30 - 100 Included
Class R Fuse Kits
When installed, this kit rejects all but Class R fuses. Kits are available for field
installation. Two kits per 3P switch. For factory installation, add “CLR” suffix to
catalogue number.
Example: DT362CLR
Ampere Rating Series Catalogue Number
30 (240V) F5 RFK03
30 (600V) F5 RFK06
60 (240V) F5 RFK06
60 (600V) F5 RFK06H
100 F5 RFK10
Rainproof Bolt-On Hubs —
See page DE2-24
Watertight Hubs —
See page DE2-24
Terminal Lug Data for Type DT, DTU (Series F) Double Throw
Safety Switches
Switch
Ampere
Rating
Wires
per
Phase
Type 1, 3R, 4, 4X, 12
Wire Range AWG/kcmil Al/Cu
30–60 A, Type DT, DTU (Series F) 1 #12–2 (Al) or #14–2 (Cu)
100 A, Type DT, DTU (Series F) 1 #12–1/0 (Al) or #14–1/0 (Cu)
DE2_P21-30.fm Page 28 Monday, April 28, 2014 2:55 AM
DE2-29
DE2 SAFETY SWITCHES
Safety Switches
04/14
General Duty
Accessories
Electrical Interlock Kits
Electrical interlocks for F-Series 60-200 Ampere General Duty Safety Switches
are available factory installed or in kit form for field installation. Each kit contains
instructions for proper field mounting. A pivot arm operates from switch mecha-
nism, breaking the control circuit before the main switch blades break. Electrical
interlock kits are CSA Certified.
Electrical interlock kit catalogue number with -1 suffix indicates one normally open and one
normally closed contact; -2 indicates two normally open and two normally closed contacts.
For Electrical Interlock contact ratings, see page DE2-23.
For factory Installation, add “EI” or “EI2” to standard catalogue number.
Example: CD223NEI
Class R Fuse Kits
CSA Certified Rejection kits are available for E-Series and F-Series Safety
Switches. When installed, this kit rejects all but Class R fuses. Kits are available
for field installation.
For factory installation, add “CLR’’ suffix to standard catalogue number.
Example: CD222NCLR
* Except L111N & CD211N
Class J Fuse Kits
Provision for installing Class J fusing in 600 ampere devices is available when lug
kit GDJK600 is used. Conversion to Class J fuse spacing for 400 ampere devices
requires relocating the loadside fuse base assembly from the standard Class H
fuse location to an alternative position as marked in the enclosure. With Class J
fuses installed, the switch is CSA certified for use on systems with up to 100,000
RMS symmetrical amperes. For field installation only.
Fuse Puller Kits
Kit consists of three fuse pullers, and can be installed in 60 and 100 Ampere F-
Series Safety Switches.
Equipment Grounding Kits
Canadian general duty safety switches come complete with factory installed
Grounding kits. Additional Grounding Kits are available for field or factory
installation.
Optional Lug Kit
Kit consists of three line, three load and two neutral lugs as required for a 3-pole
400A or 600A general duty switch.
Ampere Rating Catalogue Number
60(F-Series) ElK031, or ElK032
100-200 EIK1 or EIK2
Ampere Rating Catalogue Number
30* DRK30
60
(F-series) RFK03H
100
(F-Series) RFK10
200 HRK1020
400 DRK40
600 DRK600
Ampere Rating Catalogue Number
600 Type 1 GDJK600
Application Information
For more information, consult Schneider Electric.
Ampere Rating Catalogue Number
60 (F-Series) FPK03
100 (F-Series) FPK0610
Ampere Rating Catalogue Number Wire Size AWG
30
(E-series) PK3GTA1
(2)-#12 Cu or
(2)-#10 Al or
(1)-#4 Al/Cu Max.
60
(F-Series) GTK03
(2)-#12 Cu or
(2)-#10 Al or
(1)-#4 Al/Cu Max.
100 GTK0610 (2)-#1/0 Al/Cu Max.
200 PKOGTA2 (2)-#2/0 Al/Cu Max.
400
600
PKOGTA2
(two required)
(2)-#2/0 Al/Cu Max.
Per Lug
Ampere Rating Catalogue Number Wire Size AWG/Kcmil
400 or 600A
Type 1 (Series E3) GD4060LK
(1) 1/0 to 600 or
(2) 1/0 to 500 or
(4) 1/0 to 250
DE2_P21-30.fm Page 29 Monday, April 28, 2014 2:55 AM
DE2-30
Safety Switches
DE2 SAFETY SWITCHES
04/14
Application Information
Enclosures
Enclosure Type
Non-Hazardous Locations Hazardous Locations
Provides Protection Against... 1 2 3 3R 4 4X 5 12 7A 7B 7C 7D 9E 9F 9G
Accidental contact with enclosed equipment X X X X X X X X X X X X X X X
Dripping and light splashing of non corrosive liquids X X X X X X X
Limited amounts of falling dirt X X X X X X X X
Windblown dust X X X
Rain, sleet, and external ice formation X X X X
Hose directed water XX
Corrosion X
Settling airborne dust, lint, fibers, and filings X X X X X
Circulating dust X X X X
Acetylene X
Hydrogen, manufactured gas X
Ethyl ether, ethylene, cyclopropane XX
Gasoline, hexane, naphtha, benzene, butane, propane XXX
Alcohol, acetone, benzol, natural gas, lacquer solvent XXX
Metal dust X
Carbon black, coal dust, coke dust X
Flour, starch, grain dust XX
Usage
Indoors X X X X X X X X X X X X X X X
Outdoors X X X X
Application Information
For complete enclosure definitions, refer to C22.2 No. 94
HP Rating: Standard value when using fast acting one time fuses. Max. value when using dual element time delay fuse.
For more information, consult Schneider Electric.
DE2_P21-30.fm Page 30 Monday, April 28, 2014 2:55 AM

Navigation menu