Volume 01—Residential And Light Commercial

101954-Attachment 101954-Attachment 101954-Attachment 786685 Batch5 unilog cesco-content

24837-Catalog 24837-Catalog 24837-Catalog 786685 Batch5 unilog cesco-content

24837-Catalog 24837-Catalog 24837-Catalog 786676 Batch5 unilog cesco-content

101954-Attachment 101954-Attachment 101954-Attachment 786849 Batch5 unilog cesco-content

24837-Catalog 24837-Catalog 24837-Catalog 786849 Batch5 unilog cesco-content

2014-07-05

: Pdf 101954-Attachment 101954-Attachment 782116 Batch5 unilog

Open the PDF directly: View PDF PDF.
Page Count: 419

DownloadVolume 01—Residential And Light Commercial
Open PDF In BrowserView PDF
Electrical Sector Solutions

Volume 1 Residential and Light Commercial

Eaton Corporation
Electrical Sector
1111 Superior Ave.
Cleveland, OH 44114
United States
877-ETN-CARE (877-386-2273)
Eaton.com
© 2010 Eaton Corporation
All other trademarks are property
of their respective owners.
All Rights Reserved
Printed in USA
Publication No. CA08100002E / MSC
December 2010

Volume 1:

Residential and
Light Commercial

Volume 1—Residential and Light Commercial
Tab 1—Loadcenters and Circuit Breakers . . . . . . . . . . . . . . . . . . . . . .

V1-T1-1

Tab 2—Surge Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

V1-T2-1

Tab 3—Residential Standby Backup Power Solutions . . . . . . . . . . . .

V1-T3-1

Tab 4—Structured Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

V1-T4-1

Tab 5—Metering Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

V1-T5-1

Tab 6—Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

V1-T6-1

Tab 7—Air Conditioning Disconnects . . . . . . . . . . . . . . . . . . . . . . . . .

V1-T7-1

Appendix 1—Eaton Terms & Conditions . . . . . . . . . . . . . . . . . . . . . . .

V1-A1-1

Appendix 2—Catalog Parent Number Index . . . . . . . . . . . . . . . . . . . .

V1-A2-1

Appendix 3—Alphabetical Product Index . . . . . . . . . . . . . . . . . . . . . .

V1-A3-1

1

Copyright
Dimensions, Weights and Ratings
Dimensions, weights and ratings given in this catalog are approximate and should not
be used for construction purposes. Drawings containing exact dimensions are available
upon request. All listed product specifications and ratings are subject to change without
notice. Photographs are representative of production units.

Terms and Conditions
All prices and discounts are subject to change without notice. When price changes
occur, they are published in Eaton’s Price and Availability Digest (PAD). All orders
accepted by Eaton’s Electrical Sector are subject to the general terms and conditions
as set forth in Appendix 1—Eaton Terms & Conditions.

Technical and Descriptive Publications
This catalog contains brief technical data for proper selection of products. Further
information is available in the form of technical information publications and illustrated
brochures. If additional product information is required, contact your local Eaton
Products Distributor, call 1-800-525-2000 or visit our website at www.eaton.com.

Compliance with Nuclear Regulation 10 CFR 21
Eaton products are sold as commercial grade products not intended for application in
facilities or activities licensed by the United States Nuclear Regulatory Commission
for atomic purposes, under 10 CFR 21. Further certification will be required for use of
these products in a safety-related application in any nuclear facility licensed by the
U.S. Nuclear Regulatory Commission.

WARNING
The installation and use of Eaton products should be in accordance with the provisions
of the U.S. National Electrical Code® and/or other local codes or industry standards that
are pertinent to the particular end use. Installation or use not in accordance with these
codes and standards could be hazardous to personnel and/or equipment.

These catalog pages do not purport to cover all details or variations in equipment, nor to provide for
every possible contingency to be met in connection with installation, operation or maintenance.
Should further information be desired or should particular problems arise which are not covered
sufficiently for the purchaser’s purposes, the matter should be referred to the local Eaton Products
Distributor or Sales Office. The contents of this catalog shall not become part of or modify any prior
or existing agreement, commitment or relationship. The sales contract contains the entire
obligation of Eaton’s Electrical Sector. The warranty contained in the contract between the parties
is the sole warranty of Eaton. Any statements contained herein do not create new warranties or
modify the existing warranty.

Copyright ©2014 Eaton, All Rights Reserved.

Introduction

Eaton is a global leader in power distribution, power quality,
control and automation, and monitoring products.
At Eaton, we believe a reliable, efficient and safe power system is the foundation of every
successful enterprise. Through innovative technologies, cutting-edge products and our highly
skilled services team, we empower businesses around the world to achieve a powerful advantage.
In addition, Eaton is committed to creating and maintaining powerful customer relationships built
on a foundation of excellence. From the products we manufacture to our dedicated customer
service and support, we know what’s important to you.

Solutions
Eaton takes the complexity out of power systems management with a holistic and strategic
approach, leveraging our industry-leading technology, solutions and services. We focus on
the following three areas in all we do:
●

Reliability—maintain the
appropriate level of power
continuity without
disruption or unexpected
downtime

●

Efficiency—minimize
energy usage, operating
costs, equipment footprint
and environmental impact

●

Safety—identify and
mitigate electrical hazards
to protect what you value
most

Using the Eaton Catalog Library
As we grow, it becomes increasingly difficult to include all products in one or two comprehensive
catalogs. Knowing that each user has their specific needs, we have created a library of catalogs for our
products that when complete, will contain 15 volumes. Since the volumes will continuously be a work
in progress and updated, each volume will stand alone. Refer to our volume directory, MZ08100001E,
for a quick glance of where to look for the products you need. The 15 volumes include:
●

●

●

●

●

●

Volume 1—Residential
and Light Commercial
(CA08100002E)
Volume 2—Commercial
Distribution (CA08100003E)
Volume 3—Power
Distribution and Control
Assemblies (CA08100004E)
Volume 4—Circuit
Protection (CA08100005E)
Volume 5—Motor Control
and Protection
(CA08100006E)
Volume 6—Solid-State
Motor Control
(CA08100007E)

●

●

●

●

●

Volume 7—Logic Control,
Operator Interface and
Connectivity Solutions
(CA08100008E)
Volume 8—Sensing
Solutions (CA08100010E)
Volume 9—Original
Equipment Manufacturer
(CA08100011E)
Volume 10—Enclosed
Control (CA08100012E)
Volume 11—Vehicle and
Commercial Controls
(CA08100013E)

●

●

●

●

Volume 12—Aftermarket,
Renewal Parts and Life
Extension Solutions
(CA08100014E)
Volume 13—Counters,
Timers and Tachometers
(CA08100015E)—Available
in electronic format only
Volume 14—Fuses
(CA08100016E)—Available
in electronic format only
Volume 15—Solar Inverters
and Electrical Balance of
System (CA08100018E)

These volumes are not all-inclusive of every product, but they are meant to be an overview
of our product lines. For our full range of product solutions and additional product information,
consult Eaton.com/electrical and other catalogs and product guides in our literature library.
These references include:
●

The Consulting Application
Guide (CA08104001E)

●

The Eaton Power Quality
Product Guide (COR01FYA)

If you don’t have the volume that contains the product or information that you are looking for,
not to worry. You can access every volume of the catalog library at Eaton.com/electrical in the
Literature Library.
By installing our Automatic Tab Updater (ATU), you can be sure you always have the most recent
version of each volume and tab.

Volume 1—Residential and Light Commercial

CA08100002E—April 2014

www.eaton.com

i

Introduction

Icons
Green Leaf
Eaton Green Solutions are products, systems or solutions that represent Eaton
benchmarks for environmental performance. The green leaf symbol is our
promise that the solution has been reviewed and documented as offering
exceptional, industry-leading environmental benefits to customers, consumers
and our communities. Though all of Eaton’s products and solutions are
designed to meet or exceed applicable government standards related to
protecting the environment, our products with the Green Leaf designation
further provide “exceptional environmental benefit.”

Learn Online
When you see the Learn Online icon, go to Eaton.com/electrical and search for
the product or training page. There you will find 100-level training courses,
podcasts, webcasts or games and puzzles to learn more.

Drawings Online
When you see the Drawings Online icon, go to Eaton.com/electrical and find the
products page. There you will find a tab that includes helpful product drawings
and illustrations.

Contact Us
If you need additional help, you can find contact information
under the Customer Care heading of Eaton.com/electrical.

ii

Volume 1—Residential and Light Commercial

CA08100002E—April 2014

www.eaton.com

Loadcenters and Circuit Breakers
Residential Loadcenters
and Breaker Family

1.1

Type CH Loadcenters and Circuit Breakers
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Single-Phase. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Three-Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CH Specialty Products. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Spa Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Surge Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Plug-On Neutral Loadcenter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type CH Renovation Loadcenter . . . . . . . . . . . . . . . . . . . . . . . . . .
Type CH Retrofit Interior Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Non-Metallic Loadcenter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CH Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.2

V1-T1-14
V1-T1-15
V1-T1-17
V1-T1-18
V1-T1-19
V1-T1-21
V1-T1-31

V1-T1-42
V1-T1-48
V1-T1-54
V1-T1-57
V1-T1-57
V1-T1-58
V1-T1-59
V1-T1-72
V1-T1-75

V1-T1-88
V1-T1-89
V1-T1-89

V1-T1-93
V1-T1-94

Classified Circuit Breakers
Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Enclosed Breakers
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.5

V1-T1-14

Loadcenter Interiors/OEM Loadcenters
Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Standards and Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.4

V1-T1-7
V1-T1-12

Type BR Loadcenters and Circuit Breakers
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Single-Phase. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Three-Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BR Specialty Products. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Spa Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Riser Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type BR Renovation Loadcenter. . . . . . . . . . . . . . . . . . . . . . . . . . .
Type BR Retrofit Interior Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BR Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

1.3

V1-T1-2

V1-T1-96
V1-T1-97
V1-T1-99
V1-T1-99
V1-T1-100

1
1
1
1
1
1
1

Learn
Online

1
1
1
1
1
1
Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-1

1.1
1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Eaton Type CH Convertible Family

Contents
Description

1

Overview
Product Description . . . . . . . . . . . . . . . . . . . . .
Features, Benefits and Functions . . . . . . . . . .
Standards and Certifications . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection. . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . .
CH Specialty Products . . . . . . . . . . . . . . . . . . . . .
CH Loadcenter Options and Accessories . . . . . . .
CH Circuit Breakers. . . . . . . . . . . . . . . . . . . . . . . .

1
1
1
1
1

Page
V1-T1-3
V1-T1-3
V1-T1-4
V1-T1-6
V1-T1-7
V1-T1-29
V1-T1-14
V1-T1-22
V1-T1-31

1
1
1
1

Overview

1

Product Selection Guide

1

CH Loadcenters

1

Description

1

Single-phase, three-wire, 120/240 Vac
Three-phase, three-wire, 240V corner grounded delta

1

Short-Circuit Current Rating

1
1
1
1

Service

10 kAIC: All single- and three-phase loadcenters 40–400A, 2–42 circuits except when
series ratings are applied
25 kAIC: All factory-installed main breakers single-phase loadcenters rated 150–225A
using Type CSR main breakers

Single-phase
Main breaker: 100, 125, 150, 200, 225, 400A
Main lugs: 40, 70, 125, 150, 200, 225, 400A

1

Type CH: 10–150A. Single-, two- and three-pole. Selected amperages available in shunt
trip, HACR and switching duty
Ground fault circuit interruptors: 15–60A
Type CH-HID: 15–30A. Single-, two- and three-pole
CH-HM high magnetic
CH-M50 high ambient

Branch Breakers

1

Enclosures

1

Loadcenter and Breaker Accessories

1
1
1
1

Three-phase
Main breaker: 150, 200, 225, 300, 400A
Main lugs: 125, 150, 200, 225, 400A

Convertible Loadcenters
Main breaker or main lugs: single-phase up to 225A

1

35 kAIC available on convertible units using CSH main breaker
42 and 100 kAIC are available on some styles: single-phase and three-phase

Main Breaker/Main Lug Loadcenters

1
1

Three-phase, four-wire, 208Y/120 Vac
Three-phase, three-wire, 240 Vac delta

NEMA® Type 1 indoor

Type CH-AFCI arc fault circuit interrupter
Type CHP: 10–125A. Single-, two- and three-pole. three-position commercial trip
Selected amperages available in HACR switching duty
Type CHP-HID: 15–30A. Single-, two- and three-pole
Type CHP-GFCI: 15–30A. Single-pole ground fault breakers

NEMA Type 3R outdoor.

Branch circuit breaker:
Auxiliary components
Hold-down kits
Handle ties
Lockoffs
Lockdogs

Complete line of ground bar kits 5, 10, 14 and 21 circuits, some with additional #2/0 lugs
Each terminal will accommodate: (3) #14–#10 Cu/Al or (1) #14–#4 Cu/Al
Sub-feed lugs 125, 150A—two- and three-pole
Shunt trips
Universal rainproof conduit hubs Group One: 3/4, 1, 1-1/4, 1-1/2, 2 inches (19.1, 25.4, 31.8, 38.1, 50.8 mm)
Group Two: 2, 2-1/2, 3 inches (50.8, 63.5, 76.2 mm)
Adapter plate

Bussing
Silver flash plated copper bus is a standard feature

V1-T1-2

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Product Description

Features, Benefits and Functions

Loadcenters are enclosures
specifically designed to
house the branch circuit
breakers and wiring required
to distribute power to
individual circuits. They
contain either a main breaker
when used at the service
entrance point or a main lug
when used as a sub-panel
to add circuits to existing
service. The main breaker
protects the main entire
panel and can be used as
a service disconnect. The
branch breakers protect the
wires leading to individual
electrical loads such as
fixtures and outlets.

Loadcenter Construction
Eaton’s Type CH loadcenters
feature silver flash plated
copper bus in all interiors. Stabs
are rated 200A throughout
the CH line. Therefore, the
sum of the handle ratings
connected to any one stab is
limited to 200A maximum.
NEMA 1 boxes are
manufactured from
cold rolled 16 gauge sheet
steel. Raintight boxes are
manufactured from galvanized
steel. All boxes and trims are
finished using an electrostatic
powder coat, baked urethane
paint process.
Neutrals
Eaton Type CH loadcenters
feature two types of neutrals:
Insulated/Bondable Split
Neutral
Panels are supplied with split
insulated neutrals with an
insulated cross strap. For
service entrance applications,
the neutral must be bonded
by using the bonding strap
supplied with the panel. For
non-service entrance (subpanel) applications, the panel
may be installed with the
bonding strap not connected
to the neutral. Separate
ground bars must be used on
non-service entrance panels.

1.1
1

Insulated/Bondable Single
Neutral
Panels are supplied with a
single insulated neutral. For
service entrance applications,
all that is required to bond the
neutral is to loosen the
bonding screw and the
neutral screw directly beside
it, insert the bonding strap
into the neutral bar, and retighten both connections. The
single neutral can be moved
by the contractor to the other
side of the panel, if desired.
When used as a service
entrance panel, unused
neutral connections may be
used for the termination of
equipment grounds. For nonservice entrance (sub-panel)
applications, the panel may
be installed with the bonding
strap not connected to the
neutral. Separate ground bars
must be used on non-service
entrance panels.
Inboard Plug-On Neutral
Code changes and higher
safety standards are
leading to more arc fault
circuit interrupter (AFCI)
installations. With the
electrical contractor in mind,
Eaton has revolutionized the
way Combination AFCIs are
installed with the Plug-on
Neutral line of loadcenters
and breakers. This unique
product solution enables the
contractor to connect the
breaker directly to the neutral
bar, eliminating the need for
wiring a pigtail.

Grounds
In service entrance
applications where the
neutral is bonded, unused
neutral holes may be used
for terminating ground
conductors. In sub-feed
panels, the neutral must be
isolated (non-bonded), and
ground wires must be
terminated on a separate
ground bar.
The insulated/bondable
single/split neutral panels
have sufficient terminations
for both ground and neutral
conductors. The insulated/
bondable single split neutral
panels are supplied with a
separate factory-installed
ground bar if the catalog
number contains a “G.” If
not, a separate ground bar
should be installed. Insulated/
Bondable Single Neutral
panels are supplied without a
ground bar (unless otherwise
noted), and ground bar kits, if
needed, must be purchased
separately.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-3

1.1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

1

Standards and Certifications

1

UL® Listings
All Eaton Type CH loadcenters
are listed under UL File E8741.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Neutral and Ground Terminals
The standard terminals on
grounds and neutrals are rated
to accept (3)—#14–#10 Cu/Al
or (1)—#14–4 wires. For larger
cables, add-on neutral lugs
may be ordered from the
Accessories.
Note: NEC® allows only one
current carrying conductor
per hole on neutrals unless
otherwise noted.

Bottom-Fed Loadcenters
When the power cable is
brought into the loadcenter
from below the panel; then
the main lug panels, and
single-phase, 225A and
below, loadcenters can be
rotated 180 degrees to allow
straight-in wiring of power
cables to the main terminals.
Because the CSR main circuit
breaker handle operates
horizontally, the orientation
of the main circuit breaker
handle is consistent with
the requirements of NEC
Article 240.81.
Gutter Splicing
Loadcenters are not UL listed
as wiring troughs. Therefore,
gutter splicing of riser cables
to tap off to the main device
is not permitted. Refer to
NEC Article 373.8.

1
1
1
1
1
1
1

Fire Rating
Due to the numerous
openings in both loadcenter
boxes and trims, they should
not be mounted in firewalls.
There is no approval method
for sealing the enclosures for
this application.
Date Code
The date of manufacture of
each loadcenter is printed on
the outside of the carton as
well as inside the loadcenter.
On the carton, the date code
is printed on the end carton
label. In the loadcenter, the
date code is located on the
small white label located on
the right side wall (with the
main device on top).
The date code is in the
following format: F # # # &.
The “F” is the numeric code
for the Lincoln, IL plant,
and the three numbers
are the year and week of
manufacture, e.g., 023. The
“&” sign at the end signifies
the decade of the 2000s.
The “!” at the end signifies
the decade of the 2010s.
Therefore, the date code
F023& would indicate
that the product was
manufactured in the 23rd
week of 2000. The 1980s
are represented by a
“+” sign and the 1990s
are represented by a “=”
at the end of the code.

Plug-On Type CH Breakers
Quick-make, quick-break
switch mechanism combined
with inverse time element
tripping operation and tripfree handle design. Type CH
circuit breakers trip to the
OFF position eliminating
nuisance callbacks. The
thermal-magnetic trip curve
avoids nuisance tripping on
mild overloads while reacting
almost instantaneously
to severe short-circuit
conditions. CHF breakers
include a ‘trip flag’ to
differentiate between a
tripped breaker and one that
has been turned off.
Multipole breakers have
internal common trip
connection to operate all
poles simultaneously.
Handles are marked with
ON-OFF indication and
ampere rating of the breaker.
Type CH breakers meet
UL Standard 489, NEMA
standards, and Federal Spec
Classification W-C 375 b/Gen.
They are UL listed under File
Number E11713, E8741,
E3624 and E51287: and
CSA® certified file number
LR87196, except Type
CHT breakers.
Type CH Circuit Breaker Ratings
Single- and double-pole CH
breakers rated 15 and 20A
have low instantaneous
magnetic trip levels. The 15
and 20A breakers with “HM”
suffix have high magnetic trip
settings recommended for
circuits with inherently high
inrush currents. All Type CH
breakers are marked for
heating, air conditioning
and refrigeration (HACR)
equipment application.
Single-pole 15–20A breakers
are also suitable for switching
duty (SWD). Shunt trip coils
operate on 120 Vac and
require one additional pole
space per breaker.

1
1
1
V1-T1-4

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

1.1

Type CH Loadcenter

1

Extra 1.5 inch Knockout
(38.1 mm)
■ Larger knockout provides
easier installation and time
savings for renovation
installations
Top or Bottom Feed
Straight-in wiring saves labor
and material

“Tangential” Center Knockout
■ Easier installation for conduit
applications

1

Unique Sandalwood Finish
■ Aesthetically appealing,
scratch-resistant powder
coating

1
1

■
■

1

Neutral Bus (Strap)

One panel for either top or
bottom applications

■

1

Easily removable for
sub-panel applications

1

2/0 Lug
Easily removable and can be
installed in any location
on the neutral bar

■

1

Bonding Z-Strap
■ Provides easy field
conversion for service
entrance applications

Commercial Grade Main
Breaker
■ 25 kAIC series rated main
breaker in 150A–225A loadcenters. 35, 42 and 100 kAIC
series ratings are available
■

1
1

Twin Neutral Bars
■ Minimum 150% neutral
capacity

1

Type CHF AFCI/GFCI/Thermal Magnetic Breakers
■ Advanced electronics
effectively reduce nuisance
tripping

Optional convertible design—
reduces inventory
requirements

One Piece Silver-Flashed
Copper Bus
■ Provides superior conductivity,
corrosion resistance and durability
Drywall Marking on Enclosure
Indicates proper mounting
depth for flush applications

■

■

CHF AFCI breakers have a
standard diagnostic LED
indicating 1 of 7 trip codes

■

Mechanical flag for trip
indication (on thermal-magnetic
AFCI and GFCI)

■

All CH breakers provide
industry exclusive 2-position
handle with simple
1 step reset

●

Lifetime loadcenter
warranty
Lifetime warranty on
CH circuit breakers

1
1
1
1
1
1
1

Steel Backpan
Provides solid and reliable
breaker mounting—single
piece design for stability
and durability

●

1

1

■

Warranty
The minimum warranty
for residential loadcenters,
breakers and surge protection
devices shall be as follows:

1

1

Single Keyhole Mounting
■ One keyhole at the top
and bottom provides easier
mounting and leveling

1
1
1

●

●

1

Lifetime warranty on
CHSPT2ULTRA including
$75,000 connected
equipment warranty
1-year warranty on plug-in
surge protective device
(CHSA)

1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-5

1.1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

1

Catalog Number Selection

1

Loadcenters 100–225A and 12–42 Circuits

CH 42 B

1
1

LC Type
Type CH 3/4-inch (19.1 mm)
branch circuit breakers

1

Number of Circuits
Selection circuits
2
20
4
22
8
24
12
28
14
30
16
32
18
42

1
1
1
1

L
B
N
H

200

K

Construction
Blank = Standard
PN = Plug-on neutral

Phases
Blank = Single-phase
3
= Three-phase

1
1

Accessories
Blank = Standard
EC
= Surge ready
SUR = Surge factory
installed

Indoor Covers Ordered Separately

1

CH

1

8 K F

Type CH

1

Factory Options
Blank = Standard
SUR = Surge/surge ready

1

Loadcenter
Cover Series

Mounting
F = Combination
flush/surface
S = Surface

Accessories
Blank = Standard
M
= Mechanical interlock

Box Size
Indicated in loadcenter
catalog number

1
1

Box Sizes
B
C
D
E
G
J
K
L
R = Outdoor (no cover)

Bus Amperes
40
150
70
200
100
225
125

Main Device
= Main lug only
= Main breaker
= Convertible
= High AIC
main breaker

Note: All combinations are not valid, refer to the catalog section.

1
1
1
1
1
1
1
1
1
1
1
1
1
V1-T1-6

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

1.1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Product Selection

1

Single-Phase—Main Circuit Breaker Loadcenters—10/25 kAIC
CH42B200K

1

Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Split Neutral (Unless Otherwise Noted)
Main
Breaker
Type

Main
Ampere
Rating

Maximum Number
3/4-Inch (19.1 mm)
of Poles

Enclosure
Type

Box
Size

Wire Size Range
Cu/Al 60°C or 75°C
for Main Breaker

Loadcenter 12
Catalog Number

CH
10 kAIC

100

14

Indoor

B

#6–1/0

125

CSR
25 kAIC

150

200

225

DK
10 kAIC

1

Loadcenter Cover
Catalog Number
Combination 3

Surface

CH14B100B 4

CH8BF

CH8BS

14

Outdoor

B

#6–1/0

CH14B100R 5

—

—

18

Indoor

C

#6–1/0

CH18B100C 4

CH8CF

CH8CS

18

Outdoor

C

#6–1/0

CH18B100R 5

—

—

22

Indoor

C

#6–1/0

CH22B100C 4

CH8CF

CH8CS

22

Outdoor

C

#6–1/0

CH22B100R 5

—

—

30

Indoor

D

#6–1/0

CH30B100D 4

CH8DF

CH8DS

30

Outdoor

D

#6–1/0

CH30B100R 5

—

—

22

Indoor

C

#6–1/0

CH22B125C 4

CH8CF

CH8CS

22

Outdoor

C

#6–1/0

CH22B125R 5

—

—

30

Indoor

D

#6–1/0

CH30B125D 4

CH8DF

CH8DS

30

Outdoor

D

#6–1/0

CH30B125R 5

—

—

8

Outdoor

E

#2–300 kcmil

CH8B150RF 6

—

—

24

Indoor

E

#2–300 kcmil

CH24B150E 4

CH8EF

CH8ES

24

Outdoor

E

#2–300 kcmil

CH24B150R 5

—

—

32

Indoor

J

#2–300 kcmil

CH32B150J 4

CH8JF

CH8JS

32

Outdoor

J

#2–300 kcmil

CH32B150R 5

—

—

8

Outdoor

E

#2–300 kcmil

CH8B200RF 6

—

—

24

Indoor

E

#2–300 kcmil

CH24B200E 4

CH8EF

CH8ES

5

—

—

CH8JF

CH8JS

24

Outdoor

E

#2–300 kcmil

CH24B200R

32

Indoor

J

#2–300 kcmil

CH32B200J 4
5

32

Outdoor

J

#2–300 kcmil

CH32B200R

—

—

42

Indoor

K

#2–300 kcmil

CH42B200K 4

CH8KF

CH8KS

42

Outdoor

K

#2–300 kcmil

CH42B200R 5

—

—

32

Indoor

J

#2–300 kcmil

CH32B225J 4

CH8JF

CH8JS

32

Outdoor

J

#2–300 kcmil

CH32B225R 5

—

—

42

Indoor

K

#2–300 kcmil

CH42B225K 4

CH8KF

CH8KS

42

Outdoor

K

#2–300 kcmil

CH42B225R 5

—

—
7

CH7PMS
CH7PMS

300

42

Indoor

PM

(2) 3/0–250 kcmil

CH42PM300

CH7PMF

400

42

Indoor

PM

(2) 3/0–250 kcmil

CH42PM400

CH7PMF 7

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Notes
1 All main circuit breaker loadcenters are listed for use as service entrance equipment.
2 Ground bar kits priced separately. See Page V1-T1-25.
3 Combination style covers may be used in surface or flush applications.
4 Can be top or bottom fed by rotating the enclosure and trim 180 degrees.
5 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-25.
6 Panel includes #4–300 kcmil feed-through lugs.
7 This cover is for flush applications only (not combination).

1
1
1

Box sizes Pages V1-T1-27 and V1-T1-28.

1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-7

1.1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

1

Single-Phase—High Interrupting Rated Main Circuit Breaker Loadcenters—100 kAIC

1

Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Split Neutral

1

Main
Breaker
Type

Main
Ampere
Rating

Maximum Number
3/4-Inch (19.1 mm)
Poles

Enclosure
Type

Box
Size

Wire Size Range
Cu/Al 60°C or 75°C
for Main Breaker

Loadcenter 1
Catalog Number

1

CHB4
100 kAIC 5

100

32

Indoor

L

#6–1/0

CH32H100L 3
4

1

CHH
100 kAIC 5

150

Loadcenter Cover
Catalog Number
Combination 2

Surface

CH8LF

CH8LS

—

—

32

Outdoor

L

#6–1/0

CH32H100R

32

Indoor

L

#2/0–300 kcmil

CH32H150L

CH8LF

CH8LS

32

Outdoor

L

#2/0–300 kcmil

CH32H150R 4

—

—

32

Indoor

L

#2/0–300 kcmil

CH32H200L

CH8LF

CH8LS

1

32

Outdoor

L

#2/0–300 kcmil

CH32H200R 4

—

—

42

Indoor

L

#2/0–300 kcmil

CH42H200L

CH8LF

CH8LS

1

42

Outdoor

L

#2/0–300 kcmil

CH42H200R 4

—

—

42

Indoor

L

#2/0–300 kcmil

CH42H225L

CH8LF

CH8LS

—

—

1

200

225

1
1
1
1

42

Outdoor

L

#2/0–300 kcmil

CH42H225R

Notes
1 All main circuit breaker loadcenters are listed for use as service entrance equipment.
2 Combination style covers may be used in surface or flush applications.
3 Loadcenter can be top or bottom fed by rotating the enclosure and trim 180 degrees.
4 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-25.
5 Series rated for 100 kAIC with all Types CH, CHT and CHP breakers.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
V1-T1-8

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

4

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

1.1

Single-Phase—Main Lug Loadcenters

1
1

Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Single Neutral

Surface

Outdoor

Main
Ampere
Rating

Maximum Number
3/4-Inch (19.1 mm)
Space

Poles

Enclosure
Type

Type of Trim
(Included)

40

2

41

Indoor

Surface (no door)

2

4

1

2

41

Box
Size

Wire Size Range
Cu/Al 60°C or 75°C
for Main Lugs

Loadcenter
Catalog Number

5

#14–6

CH2L40SP 23
234

Outdoor

—

5R

#14–6

CH2L40RP

Indoor

Flush (no door)

5

#14–6

CH2L40FP 23

1
1
1
1
1

Flush

Outdoor

70

2

41

Indoor

Surface (no door)

5

#14–2

CH2L70SP 23

2

41

Outdoor

—

5R

#14–2

CH2L70RP 234

2

41

Indoor

Flush (no door)

5

#14–2

CH2L70FP 23

1
1
1

Surface (No Door)

Flush (No Door)

125

2

41

Indoor

Surface (no door)

6

#14–1/0

CH2L125SP 23

2

41

Outdoor

—

6R

#14–1/0

CH2L125RP 234

2

2

Outdoor

—

—

#14–1/0

CH2L125RSE2P 456

2

41

Indoor

Flush (no door)

6

#14–1/0

CH2L125FP 23

4

81

Indoor

Surface (no door)

7

#14–1/0

CH4L125SP 27

4

81

Outdoor

—

7R

#14–1/0

CH4L125RP 247

4

81

Indoor

Flush (no door)

7

#14–1/0

CH4L125FP 27

Outdoor

—

6R

#14–1/0

CH6L125R 267

Indoor

Surface (no door)

7

#6–1/0

CH8L125SP 28

Outdoor

—

7R

#6–1/0

CH8L125RP 267

Indoor

Flush (no door)

7

#6–1/0

CH8L125FP 28

1

6

12

8

16 1

8

16

1

8

16 1

1
1
1
1
1
1
1
1
1

Outdoor

1
1
Notes
1 Requires the use of Type CHNT breakers.
2 Ground bar kits priced separately, see Page V1-T1-25.
– For 2/4 and 6/12 circuit loadcenters use Type GBK5 or GBK520 ground bar
– For 4/8 and 8/16 circuit loadcenters use Type GBK10 ground bar
– Ground bars mount to the left side wall of the enclosure for the 4/8, 6/12 and 8/16 circuit loadcenters
3 Suitable for use as service equipment when not more than two service disconnecting mains are provided or when not used as a lighting and appliance panelboard
(see Article 408.34 of the NEC).
4 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-25.
5 For use as service entrance applications only.
6 Neutral/ground holes (6) #14–6 and (3) #14–2/0 AWG Cu/AI.
7 Suitable for use as service equipment when not more than two service disconnecting mains are provided or when not more than six service disconnecting mains are
provided and when not used as a lighting and appliance panelboard (see Article 408.34 of the NEC).
8 Suitable for use as service equipment when a main breaker is used or when not more than six service disconnecting mains are provided and when not used as a lighting
and appliance panelboard (see Article 408.34 of the NEC).
Box sizes Pages V1-T1-27 and V1-T1-28.

1
1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-9

1.1
1

CH42L225G

1
1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Split Neutral—Factory-Installed Ground Bar
Loadcenter Cover
Catalog Number

Main
Ampere
Rating

Maximum Number
3/4-Inch (19.1 mm)
Poles

Enclosure
Type

Box
Size

Wire Size Range
Cu/Al 60°C or 75°C
for Main Lugs

Loadcenter
Catalog Number

Combination

Surface

125

12

Indoor

B

#6–2/0

CH12L125B 1

CH8BF

CH8BS

12

Outdoor

B

#6–2/0

CH12L125R 12

—

—

1

1

16

Indoor

B

#6–2/0

CH16L125B

CH8BF

CH8BS

16

Outdoor

B

#6–2/0

CH16L125R 12

—

—

20

Indoor

C

#6–2/0

CH20L125C 1

CH8CF

CH8CS

1

20

Outdoor

C

#6–2/0

CH20L125R 12

—

—

24

Indoor

C

#6–2/0

CH24L125C 1

CH8CF

CH8CS

1

24

Outdoor

C

#6–2/0

CH24L125R 12

—

—

1

150

1

24

Indoor

D

#4–300 kcmil

CH24L150D 1

CH8DF

CH8DS

24

Outdoor

D

#4–300 kcmil

CH24L150R 23

—

—

CH8DF

CH8DS

1

32

Indoor

D

#4–300 kcmil

CH32L150D

32

Outdoor

D

#4–300 kcmil

CH32L150R 23

—

—

12

Indoor

D

#4–300 kcmil

CH12L200D 1

CH8DF

CH8DS

12

Outdoor

D

#4–300 kcmil

CH12L200R 23

—

—

16

Indoor

D

#4–300 kcmil

CH16L200D 1

CH8DF

CH8DS

16

Outdoor

D

#4–300 kcmil

CH16L200R 23

—

—

24

Indoor

D

#4–300 kcmil

CH24L225D 1

CH8DF

CH8DS

1

24

Outdoor

D

#4–300 kcmil

CH24L225R 23

—

—

32

Indoor

D

#4–300 kcmil

CH32L225D

CH8DF

CH8DS

1

32

Outdoor

D

#4–300 kcmil

CH32L225R 23

—

—

42

Indoor

G

#4–300 kcmil

CH42L225G 3

CH8GF

CH8GS

42

Outdoor

G

#4–300 kcmil

CH42L225R 23

—

—

42

Indoor

P

(2) 1/0–300 kcmil
(1) 750 kcmil

CH42PL400 4

CH7PF 5

CH7PS

1
1

200

1
1

225

1

400

1

1

Notes
1 Suitable for use as service equipment when not more than six disconnecting means are provided and when not used as a lighting and appliance panelboard
(see Article 408.34 of the NEC).
2 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-25.
3 Suitable for use as service equipment when a circuit breaker is used as a main breaker. The main breaker is backfed and requires hold-down bracket kit
catalog number CH125RB.
4 Suitable for use as service equipment when a circuit breaker is used as a main breaker. The main breaker is backfed and must be a Type CHB.
The breaker cannot be a Type CH.
5 This cover is for flush application only (not combination).

1
1
1
1

Box sizes Pages V1-T1-27 and V1-T1-28.

1
1
1
1
1
1
1
1
1
1
V1-T1-10

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

1.1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Convertible Loadcenters MCB or MLO—Base Units and Main Devices—10/25/35 kAIC
Complete assembly consists of: loadcenter, cover, and either main breaker kit or main lug kit.

1
1

Indoor—Single-Phase—Three-Wire—120/240V—Insulated/Bondable Split Neutral—Top or Bottom Feed
Maximum
Main Ampere
Rating

Maximum
Number of
Single Poles

Box
Size

Loadcenter Box
and Panel
Catalog Number 1

125

22

C

CH22N125C

200

225

32

42

J

K

CH32N200J

Main Lug Kit

Main Breaker Kit

Combination

Surface

Wire
Size

Catalog
Number

kAIC
Rating

Wire
Size

Catalog Number

CH8CF

CH8CS

#10–1/0

CHL125N

10

#10–1/0

CH2100N 3

—

CH2125N 3

—

CSR2125N

CSH2125N 4

CSR2150N

CSH2150N 4

CSR2175N

CSH2175N 4

CSR2200N

CSH2200N 4

CSR2125N

CSH2125N 4

CSR2150N

CSH2150N 4

CSR2175N

CSH2175N

4

CSR2200N

CSH2200N 4

CSR2225N

CSH2225N 4

CH8JF

CH42N225K

1

Loadcenter Cover
Catalog Number

CH8KF

CH8JS

CH8KS

#4–300
kcmil

#4–300
kcmil

CHL225N

CHL225N

25/35 2

25/35

2

#2–300
kcmil

#2–300
kcmil

1
1

Maximum
Number of
Single Poles

Loadcenter Box
and Panel
Catalog Number 1

Main Lug Kit

Box
Size

Wire
Size

Catalog
Number

kAIC
Rating

Wire
Size

Catalog Number

125

22

C

CH22N125R 5

#10–1/0

CHL125N

10

#10–1/0

CH2100N 3
CH2125N 3

—

200

8

E

CH8N200RF 567

#4–300 kcmil

CHL225N

25/35 2

#2–300 kcmil

CSR2125N

CSH2125N

CSR2150N

CSH2150N

CSR2175N

CSH2175N

CSR2200N

CSH2200N

CSR2125N

CSH2125N 4

CSR2150N

CSH2150N 4

CSR2175N

CSH2175N 4

CSR2200N

CSH2200N 4

CSR2125N

CSH2125N 4

CSR2150N

CSH2150N 4

CSR2175N

CSH2175N 4

CSR2200N

CSH2200N 4

CSR2225N

CSH2225N 4

225

42

J

K

CH32N200R 5

CH42N225R 5

#4–300 kcmil

#4–300 kcmil

Main Breaker Kit

CHL225N

CHL225N

25/35 2

25/35 2

#2–300 kcmil

#2–300 kcmil

1
1
1
1
1

Maximum
Main Ampere
Rating

32

1

1

Outdoor—Single-Phase—Three-Wire—120/240V—Insulated/Bondable Split Neutral (Unless Otherwise Noted)

200

1

1
—

1

Notes
1 Panel does not include main. Order main breaker or main lug kit separately.
2 If 35 kAIC is required, use CSH breaker.
3 Hold-down kit included.
4 35 kAIC series combination rating is obtained when Types CH, CHT and CHP branch breakers are used with CSH main.
5 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-25.
6 Includes feed-through lugs for both phase and neutral conductors.
7 Insulated/bondable single neutral.

1
1
1
1
1
1
1
1
1
1
1
1

Interrupting rating depends on main circuit breaker selected.

1
1
1
Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-11

1.1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

1

Three-Phase—Main Circuit Breaker Loadcenters—10 kAIC

1

CH42B3200L

Three-Phase Four-Wire—208Y/120 Vac or 240 Vac Insulated/Bondable Split Neutral

1
1

Main
Ampere
Rating

Maximum Number
3/4-Inch (19.1 mm)
Poles

Enclosure
Type

Box
Size

Wire Size Range
Cu/Al 60°C or 75°C
for Main Breaker

Loadcenter 12
Catalog Number

CC
10 kAIC

150

30

Indoor

L

#1–4/0

CH30B3150L

CH8LF

CH8LS

30

Outdoor

L

#1–4/0

CH30B3150R 3

—

—

30

Indoor

L

#2/0–300 kcmil

CH30B3200L

CH8LF

CH8LS

30

Outdoor

L

#2/0–300 kcmil

CH30B3200R 3

—

—

42

Indoor

L

#2/0–300 kcmil

CH42B3200L

CH8LF

CH8LS

42

Outdoor

L

#2/0–300 kcmil

CH42B3200R 3

—

—

30

Indoor

L

#2/0–300 kcmil

CH30B3225L

CH8LF

CH8LS

30

Outdoor

L

#2/0–300 kcmil

CH30B3225R 3

—

—

42

Indoor

L

#2/0–300 kcmil

CH42B3225L

CH8LF

CH8LS

42

Outdoor

L

#2/0–300 kcmil

CH42B3225R 3

—

—

42

Indoor

PM

(2) 3/0–350 kcmil

CH424PM400

CH7PMF 4

CH7PMS

200

1
1
1

225

1
1
1

Loadcenter Cover
Catalog Number

Main
Breaker
Type

400

Combination

Surface

Three-Phase—High Interrupting Rated Main Circuit Breaker Loadcenters—100 kAIC

1
1

Three-Phase Four-Wire—208Y/120 Vac or 240 Vac Insulated/Bondable Split Neutral
Loadcenter Cover
Catalog Number

1

Main
Breaker
Type

Main
Ampere
Rating

Maximum Number
3/4-Inch (19.1 mm)
of Poles

Enclosure
Type

Box
Size

Wire Size Range
Cu/Al 60°C or 75°C
for Main Breaker

Loadcenter
Catalog Number 12

1

CHH
100 kAIC 5

200

30

Indoor

L

#2/0–300 kcmil

CH30H3200L

CH8LF

CH8LS

30

Outdoor

L

#2/0–300 kcmil

CH30H3200R 3

—

—

42

Indoor

L

#2/0–300 kcmil

CH42H3200L

CH8LF

CH8LS

42

Outdoor

L

#2/0–300 kcmil

CH42H3200R 3

—

—

42

Indoor

L

#2/0–300 kcmil

CH42H3225L

CH8LF

CH8LS

—

—

1
1
1
1
1
1

225

42

Outdoor

L

#2/0–300 kcmil

CH42H3225R

Notes
1 All main circuit breaker loadcenters are listed for use as service entrance equipment.
2 Ground bar kits priced separately. For ground bar kits, see Page V1-T1-25.
3 Rainproof loadcenters are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-25.
4 This cover for flush application only (not combination).
5 100 kAIC series combination rating is obtained when Types CH and CHP branch breakers are used with CHH main.

1
1
1
1
1
1
1
1
1
1
V1-T1-12

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

3

Combination

Surface

1.1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Three-Phase—Main Lug Loadcenters

1

Three-Phase Four-Wire—208Y/120 Vac or 240 Vac Insulated/Bondable Split Neutral (Unless Otherwise Noted)
Main
Ampere
Rating

Maximum Number
3/4-Inch (19.1 mm)
Spaces

125

6

Poles

Type of Trim
Included

Box
Size

Wire Size Range
Cu/Al 60°C or 75°C
for Main Lugs

Loadcenter
Catalog Number

Combination

Single

12 1

Indoor

Surface, no door

7

#14–1/0

CH6L3125SP 234

—

—

6

12 1

Outdoor

—

7R

#14–1/0

CH6L3125RP 2345

—

—

6

12

1

Indoor

Flush, no door

7

#14–1/0

CH6L3125FP

—

—

12

12

Indoor

—

B

#6–2/0

CH12L3125B 67

CH8BF

CH8BS

12

12

Outdoor

—

B

#6–2/0

CH12L3125R 567

—

—

18

18

Indoor

—

C

#6–2/0

CH18L3125C 67

CH8CF

CH8CS

—

—

CH8CF

CH8CS

234

678

18

18

Outdoor

—

C

#6–2/0

CH18L3125R

24

24

Indoor

—

C

#6–2/0

CH24L3125C 67
678

24

24

Outdoor

—

C

#6–2/0

CH24L3125R

—

—

150

30

30

Indoor

—

D

#4–300 kcmil

CH30L3150D 67

CH8DF

CH8DS

30

30

Outdoor

—

D

#4–300 kcmil

CH30L3150R 569

—

—

225

24

24

Indoor

—

D

#4–300 kcmil

CH24L3225D 67

CH8DF

CH8DS

24

24

Outdoor

—

D

#4–300 kcmil

CH24L3225R 569

—

—

30

30

Indoor

—

D

#4–300 kcmil

CH30L3225D 67

CH8DF

CH8DS

30

30

Outdoor

—

D

#4–300 kcmil

CH30L3225R 569

—

—

42

42

Indoor

—

G

#4–300 kcmil

CH42L3225G 89

CH8GF

CH8GS

400

1

Loadcenter
Cover Catalog Number

Enclosure
Type

42

42

Outdoor

—

G

#4–300 kcmil

CH42L3225R 589

—

—

42

42

Indoor

—

P

(2) 1/0–300 kcmil
(1) 750 kcmil

CH424PL400 jk

CH7PF l

CH7PS

1
1
1
1
1
1
1
1
1
1
1

Notes
1 Requires the use of CHNT breakers.
2 Suitable for use as service equipment when not more than two service disconnecting means are provided or when not more than six service disconnecting means are provided and when not used as
a lighting and appliance panelboard (see Article 408.34 of the NEC).
3 Ground bar kits priced separately, see Page V1-T1-25.
– Use GBK10 ground bar
– Ground bars mount to the left side wall of the enclosure.
4 Insulated/bondable single neutral.
5 Rainproof loadcenters are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-25.
6 Ground bar Type GBK14 is installed.
7 Suitable for use as service equipment when a circuit breaker is used as a main breaker. The main breaker is backfed and requires hold-down bracket kit catalog number Type CH125RB. Suitable for
use as service equipment when not more than six service disconnecting means are provided and when not used as a lighting and appliance panelboard (see Article 408.34 of the NEC).
8 Ground bar Type GBK21 is installed.
9 Suitable for use as service equipment when a circuit breaker is used as a main breaker. The main breaker is backfed and requires hold-down kit catalog number Type CH125RB.
j For ground bar kits, see Page V1-T1-25.
k Suitable for use as service equipment when a circuit breaker is used as a main breaker. The main breaker is backfed and must be a Type CHB. The breaker cannot be a Type CH.
l This cover for flush application only (not combination).

1

Box sizes Pages V1-T1-27 and V1-T1-28.

1

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-13

1.1
1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Contents—CH Specialty Products

Spa Panels

Description

1

Page

Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CH Specialty Products
Spa Panels
Surge Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Plug-On Neutral Loadcenter . . . . . . . . . . . . . . .
Type CH Renovation Loadcenter . . . . . . . . . . . .
Type CH Retrofit Interior Kits . . . . . . . . . . . . . .
CH Loadcenter Options and Accessories. . . . . . . .
CH Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . .

1
1
1
1

V1-T1-2

V1-T1-15
V1-T1-17
V1-T1-18
V1-T1-19
V1-T1-22
V1-T1-31

1
1
1
1
1

CH Specialty Products

1

Spa Panels

1
1
1
1
1
1
1

Product Description:

Features

Eaton’s CH Spa Panels are
premium factory-assembled
“combination” units that
provide ground fault
protection, as well as a
convenient way to turn spa
pumps on and off. The NEC
requires that all pool and spa
pumps be protected by a
ground fault interrupter and
a disconnect switch mounted
within 10 feet of the tub
or the spa.

●

●
●
●

●

Two extra circuits for
additional loads
Limited lifetime warranty
UL Listed
Tough powder-coated
galvanized steel enclosure
Factory-installed
two-pole ground fault
circuit interrupter (GFCI)

1
1

Quick-ProSM
All you need to
know to save
time and make
more money.
Specified on
certain Eaton products, the
Quick-Pro symbol allows for
immediate recognition of
products that are designed for
straightforward installation.
When you see Quick-Pro, you
know you can install quickly—
sometimes up to 50% less
than the usual installation
time—and move on to your
next job.

Product Selection

1

CH Spa Panel

1

Single-Phase Three-Wire—120/240 Vac Insulated/Bondable Neutral—
Factory-Installed Ground Bar

1

Main
Ampere
Rating

Circuit
Breaker
Included

Enclosure
Type

Type
of Trim
Included

Box
Size

Wire Size Range
Cu/Al 60°C or 75°C
for Main Lugs

Catalog
Number

1

30

CH230GF

Outdoor

—

5R

#14–1/0

CH30SPA 1

1

40

CH240GF

Outdoor

—

5R

#14–1/0

CH40SPA 2

50

CH250GF

Outdoor

—

5R

#14–1/0

CH50SPA 3

60

CH260GF

Outdoor

—

5R

#14–1/0

CH60SPA 4

1

Notes
1 Includes a CH230GFI breaker, factory installed, and two extra circuits for convenience.
2 Includes a CH240GFI breaker, factory installed, and two extra circuits for convenience.
3 Includes a CH250GFI breaker, factory installed, and two extra circuits for convenience.
4 Includes a CH260GFI breaker, factory installed, and two extra circuits for convenience.

1
1
1
V1-T1-14

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

1.1

Contents—CH Specialty Products

Surge Panel

Description

Page

Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CH Specialty Products
Spa Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Surge Panel
Plug-On Neutral Loadcenter. . . . . . . . . . . . . . .
Type CH Renovation Loadcenter . . . . . . . . . . .
Type CH Retrofit Interior Kits . . . . . . . . . . . . . .
CH Loadcenter Options and Accessories . . . . . . .
CH Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . .

1

V1-T1-2

1

V1-T1-14

1

V1-T1-17
V1-T1-18
V1-T1-19
V1-T1-22
V1-T1-31

1
1
1
1
1
1
1
1

Surge Panel
Product Description
Eaton’s Type CH Surge
Loadcenter includes a factorymounted and wired surge
suppressor device. There is
a knockout in the cover that
allows the user to view the
status indication lights on
the surge suppressor. The
CH Surge Loadcenter reduces
the surge current, helping
protect sensitive home
electronic equipment.
Save labor
by installing
a factorymounted surge
protective
device.
Factory-Installed
Surge Protection
●
Includes a CHSPT2ULTRA
and a two-pole 50A
circuit breaker
●
Increases the
effectiveness of
surge protection due
to reduced lead length
●
A modified deadfront
allows for easy viewing
of indicating lights

1

Product Selection

1

Surge Installed Loadcenters
Ampere
Rating
225
225

1

Loadcenter Cover
Catalog Number

Type

Number
of Circuits

Loadcenter
Catalog Number

Combination

Surface

Convertible

42

CHSUR42N225L 1

CHSUR8LF

CHSUR8LS

Convertible 2

42

CHSUR42L225L2 1

CHSUR8LF

CHSUR8LS

200

Main breaker

42

CHSUR42B200L2 1

CHSUR8LF

CHSUR8LS

225

Convertible

32

CHSUR32N225K 1

CHSUR8KF

CHSUR8KS

225

Convertible

2

32

CHSUR32L225K 1

CHSUR8KF

CHSUR8KS

200

Main breaker

32

CHSUR32B200K 1

CHSUR8KF

CHSUR8KS

150

Main breaker

32

CHSUR32B150K 1

CHSUR8KF

CHSUR8KS

100

Main breaker

32

CHSUR32B100K 1

CHSUR8KF

CHSUR8KS

125

Convertible 2

24

CHSUR24L125E 1

CHSUR8EF

CHSUR8ES

100

Main breaker

24

CHSUR24B100E 1

CHSUR8EF

CHSUR8ES

200

Convertible

40/40

BRSUR4040N200

Cover included

200

Main lug

40/40

BRSUR4040L200

Cover included

200

Main breaker

40/40

BRSUR4040B200

Cover included

200

Convertible

30/40

BRSUR3040N200

Cover included

200

Main lug

30/40

BRSUR3040L200

Cover included

200

Main breaker

30/40

BRSUR3040B200

Cover included

1
1
1
1
1
1
1
1
1
1
1

Notes
1 Order cover separately.
2 With main lugs installed.

1
1

Surge Ready
●
Provides a mounting
provision for
CHSPT2ULTRA
●
A modified deadfront
allows for easy viewing
of indicating lights

1
1
1
Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-15

1.1
1
1
1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Surge Ready Loadcenters (provision only, CHSPT2ULTRA and breaker not included)
Ampere
Rating

Number
of Circuits

Loadcenter
Catalog Number 1

Loadcenter Cover Catalog Number

Type

Combination

Surface

225

Convertible

42

CHEC42N225L

CHSUR8LF

CHSUR8LS

225

CHSUR8LF

CHSUR8LS

Convertible 2

42

CHEC42L225L

1

200

Main breaker

42

CHEC42B200L

CHSUR8LF

CHSUR8LS

225

Convertible 2

32

CHEC32L225K

CHSUR8KF

CHSUR8KS

1

225

Convertible

32

CHEC32N225K

CHSUR8KF

CHSUR8KS

225

Convertible

32

CHEC32N225R 3

—

—

200

Main breaker

32

CHEC32B200K

CHSUR8KF

CHSUR8KS

150

Main breaker

32

CHEC32B150K

CHSUR8KF

CHSUR8KS

100

Main breaker

32

CHEC32B100K

CHSUR8KF

CHSUR8KS

125

Convertible 2

24

CHEC24L125E

CHSUR8EF

CHSUR8ES

Main breaker

24

CHEC24B100E

CHSUR8EF

CHSUR8ES

1
1
1

100

1
1

Main Breaker Kits

1

Main Lug Kits
Catalog Number

Maximum Main Ampere Rating

Catalog Number

Maximum Main Ampere Rating

25 kAIC

35 kAIC

125

CHL125N

100

CSR2100N

CSH2100N

1

225

CHL225N

150

CSR2150N

CSH2150N

1

200

CSR2200N

CSH2200N

225

CSR2225N

CSH2225N

1
1
1
1
1
1
1
1
1
1
1
1

Technical Data and Specifications
Ratings
●
Loadcenter
●
25 kAIC main breaker, main lug only, and convertible
main breaker/main lug
●
Factory installed or provision for field-installed
surge suppressor
●
Top or bottom feed
●

Surge protective device (CHSPT2ULTRA)
●
Nominal discharge current: 20 kA (In)
●
Surge current capacity per phase: 108 kA
●
Warranty: $75,000 connected equipment 4
●
For further product ratings, see Volume 1, Tab 2.1
Surge Protection

Notes
1 Order cover separately.
2 With main lugs installed.
3 Rainproof loadcenters are furnished with hub closure plates. For rainproof hubs,
refer to Page V1-T1-25.
4 For warranty details, visit www.eaton.com/surgetrap.

1
1
1
1
1
V1-T1-16

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

1.1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Contents—CH Specialty Products

60-Circuit Plug-On Neutral Loadcenter

Description

Page

Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CH Specialty Products
Spa Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Surge Panel . . . . . . . . . . . . . . . . . . . . . . . . . . .
Plug-On Neutral Loadcenter
Type CH Renovation Loadcenter . . . . . . . . . . .
Type CH Retrofit Interior Kits . . . . . . . . . . . . . .
CH Loadcenter Options and Accessories . . . . . . .
CH Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . .

V1-T1-2
V1-T1-14
V1-T1-15
V1-T1-18
V1-T1-19
V1-T1-22
V1-T1-31

1
1
1
1
1
1
1
1
1
1
1

Plug-On Neutral
Loadcenter
Product Description
Code changes and higher
safety standards are leading
to more arc fault and ground
fault circuit interrupter
installations. Eaton offers a
unique product solution that
enables a direct connection of
the breaker to the neutral bar,
eliminating the need for
wiring a pigtail.

●

●
●

●

Time savings up to 25%
per AFCI/GFCI installation
Eliminates nuisance
tripping due to loose pigtail
connections
Clean gutter space
Easier troubleshooting
due to less wiring
Backed by a limited
lifetime warranty

1

Main Breaker Plug-On Neutral Loadcenters
Main
Breaker
Type

Main
Ampere
Rating

Max.
Number
3/4-Inch
Circuits

Max.
Number
of Poles

Enclosure
Type

CSR 25
kAIC

100

24

24

200

32

32

200

42

200

60

Features and Benefits
●

1

Product Selection

1

Cover Catalog
Number

Box
Size

Wire Size
Range
Cu/Al

Catalog
Number

Combination

Surface

Indoor

E

#2–300 kcmil

CH24BPN100E

CH8EF

CH8ES

Indoor

J

#2–300 kcmil

CH32BPN200J

CH8JF

CH8JS

42

Indoor

K

#2–300 kcmil

CH42BPN200K

CH8KF

CH8KS

120 1

Indoor

N

#2–300 kcmil

CH60BPN200N

CH8NF

—

Main Lug Only/Convertible Plug-On Neutral Loadcenters—With Factory Installed Main Lugs
Max.
Ampere
Rating

Max.
Number
3/4-Inch
Poles

Enclosure
Type

Box
Size

125

24

Indoor

E

Cover Catalog
Number

32

Indoor

J

Indoor

K

1
1

Catalog
Number

Wire Size
Range
For Main
Breaker

CH24NLPN125E

#6–300 kcmil

CSR2100N

#2–300 kcmil CH8NLEF

CH8NLES

1

#2–300 kcmil CH8NLJF

CH8NLJS

1

Combination Surface

CH32NLPN225J

#6–300 kcmil

CSR2125N

CH42NLPN225K

#6–300 kcmil

CSR2125N

1

1

CSR2100N
42

1

Main
Breaker
Kit 2

CSR2200N

225

1

Wire Size
Range
for Main Lug

CSR2125N
225

1

#2–300 kcmil CH8NLKF

CH8NLKS

CSR2150N

1
1

CSR2200N
Notes
1 Requires the use of type CHNT breakers.
2 If 35 kAIC is required, use CSH breaker equivalent.

1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-17

1.1
1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Contents—CH Specialty Products

Renovation Panel

Description

1

Page

Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CH Specialty Products
Spa Panels. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Surge Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Plug-On Neutral Loadcenter . . . . . . . . . . . . . . .
Type CH Renovation Loadcenter
Type CH Retrofit Interior Kits . . . . . . . . . . . . . .
CH Loadcenter Options and Accessories. . . . . . . .
CH Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . .

1
1
1
1

V1-T1-2
V1-T1-14
V1-T1-15
V1-T1-17
V1-T1-19
V1-T1-22
V1-T1-31

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Type CH Renovation
Loadcenter
Product Description
Eaton’s Renovation
Loadcenter is designed
for the service contractor.
With the addition of a fivecircuit terminal block factory
mounted in the top left corner
of the loadcenter, the service
contractor can terminate
short-circuit wires instead of
having to use expensive wire
nuts. Also, the Renovation
Loadcenter incorporates a
twin-stacked neutral design
that places the neutral and
ground terminations higher in
the loadcenter. Both of these
features were added without
increasing any size from a
standard loadcenter. These
features will eliminate the
need for wire nuts and make
for a much neater installation.
There is a provision to field
mount a second five-circuit
terminal block (RN5TB) in
the top right corner of the
loadcenter. Choose amongst
Eaton’s Type CH breaker
family for use in the
Renovation Panel.

Product Selection
Single-Phase—Main Circuit Breaker Loadcenters 25 kAIC 1
Single-Phase, Three-Wire—120/240 Vac—Stacked Split Neutral

Box
Size

Wire Size
Range
Cu/Al
60 or 70ºC
for Main
Breakers

Loadcenter
Catalog
Number

Combination

Main
Breaker
Type

Main
Ampere
Rating

CH

100

20

Indoor

C

#6–1/0

CH22B100CRN

CH8CFF

CH8CS

CSR

150

32

Indoor

J

#2–300 kcmil

CH32B150JRN

CH8JF

CH8JS

CSR

200

32

Indoor

J

#2–300 kcmil

CH32B200JRN

CH8J

CH8JS

CSR

200

42

Indoor

K

#2–300 kcmil

CH42B200KRN

CH8KF

CH8KS

Enclosure
Type

Branch Circuit Breakers (CH)
See Pages V1-T1-2–V1-T1-13.
Renovation Loadcenter
Description

Catalog Number

Five-circuit terminal block kit
Ground bar kits (two maximum per panel)

RN5TB
(See Page V1-T1-25)

Notes
1 100A main breaker is rated 10 kAIC.
2 Combination style covers may be used in surface or flush applications.
All main circuit breaker loadcenters are listed for use as service entrance equipment. Loadcenters
are factory-bonded for service entrance applications. Remove bonding strap for separate neutral
and ground bars for sub-feed applications.

1
1
1
1
V1-T1-18

Cover Catalog
Number 2

Max.
Number
3/4-Inch
(19.1 mm)
of Poles

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

Surface

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

1.1

Contents—CH Specialty Products

Type CH Retrofit Interior

Description

Page

Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CH Specialty Products
Spa Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Surge Panel . . . . . . . . . . . . . . . . . . . . . . . . . . .
Plug-On Neutral Loadcenter . . . . . . . . . . . . . . .
Type CH Renovation Loadcenter . . . . . . . . . . .
Type CH Retrofit Interior Kits
CH Loadcenter Options and Accessories . . . . . . .
CH Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . .
Type CH Retrofit
Adjustable Interior

V1-T1-2
V1-T1-14
V1-T1-15
V1-T1-17
V1-T1-18
V1-T1-22
V1-T1-31

1
1
1
1
1
1
1

Type CH Retrofit Interior Collar
and Assembly with Trim

1
1
1
1

Type CH Retrofit Interior Kits
Product Description

Application Description

Eaton’s unique Retrofit
Interior allows the customer
to cost-effectively and safely
upgrade an electrical service
without removing the existing
enclosure from the wall.

The Retrofit Interior is
designed and tested
specifically for renovating
an outdated electrical panel in
an apartment, a condominium
or a single family home.
These outdated panels are
being recognized by local
inspectors and other
authorities as a possible
hazard.
Opportunities to Retrofit
Single- or three-phase
●
Main lug only or main
breaker
●
Up to 42 circuits
●
Up to 225A interiors,
400A available upon
request
●
Available with CH breakers
(3/4-inch) with copper bus
or BR breakers (1-inch) with
aluminum bus
●
The minimum lifetime
warranty for residential
breakers shall be as
follows:
●
Limited lifetime
warranty on all CH
branch breakers and
loadcenters
●
Refer to Eaton for
complete warranty
details
●

1

Features and Benefits
Upgrading Existing Electrical
Infrastructure Is Simple
●
Replaces vintage brands
that have hard to find,
expensive replacement
breakers
●
Safely upgrade to arc fault
and ground fault breakers
to meet current electrical
codes
●
Maximizes number of
circuits available with
compact design
●
Eco-friendly in asbestosfilled environments
●
Exclusive design

Detailed Product Guide
For questions about retrofit
solutions, contact the Lincoln
Flex Center at 800-330-6479 or
flexcenterlincoln@eaton.com.
Be sure to provide width,
height and depth of panel.

1
1
1

Standards and Certifications

1

Meets 2008/2011/2014 NEC
wire bending requirements.

1
1
1
1
1

Save Time and Money
Throughout the Installation
●
Uses existing panel
box and wires
●
Eliminates expensive and
time-consuming drywall/
paint repair
●
Saves 2–3 hours of
installation time compared
to a complete panel
changeout
●
Eliminates precise
measurements with fieldadjustable kit

1
1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-19

1.1
1
1
1
1
1
1
1
1
1
1
1
1
1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

CH Specialty Product Selection
To select the retrofit kit:
1. From the existing box
size determine which
retrofit groups are
suitable (may be more
than one).
2. Use type of interior,
number of phases, and
type of main to find the
selection chart.
3. Select part number from
chart (if main breaker,
replace XXX with specific
amp rating).

4. Note that the overlap
of the existing wall is
the retro cover size
minus the existing
box size. If specific
measurements are
needed, communicate
that you need a custom
trim size.
5. Contact the Lincoln Flex
Center at 800-330-6479
for pricing, lead-times,
and order entry
instructions.

How to Order:
1. Measure the existing
panel enclosure to
determine appropriate
kits for your project.

Need assistance or can’t find
retrofit to fit existing
enclosure?

2. Match the existing
dimensions with the
table below to obtain the
correct catalog number.
3. Order your retrofit kit
from a local Eaton
authorized distributor.

Email or call Eaton’s
Residential Flex Center at
1-800-330-6479 for all your
retrofit needs. Go to
www.eaton.com/eccn to
locate an Eaton Certified
Contractor.

Retrofit Interior Kit Specifications
Five recommended groups: existing box height determines retro group size. Approximate Dimensions in Inches (mm).
Existing Enclosure Parameters—Inches (mm)
Catalog
Number 1

Minimum
Depth

Maximum
Depth

Minimum
Width

Minimum
Height

Phase

Main

Bus

Amperes 3

Spaces /
Circuits

UL 67
Listed

CRWCH6ML****

3.13 (79.5)

4.13 (104.9)

7.00 (177.8)

8.50 (215.9)

Single

MLO

CH

125

6

No

Cover 2

CH Retrofit Interiors and Covers
RWCH6L125N
RSCH10B125N

CRWCH12ML****

3.50 (88.9)

4.50 (114.3)

8.50 (215.9)

16.50 (419.1)

Single

MCB

CH

125

10

No

1

RSCH12L125N

CRWCH12ML****

3.50 (88.9)

4.50 (114.3)

8.50 (215.9)

16.50 (419.1)

Single

MLO

CH

125

12

No

1

RACH22B125J

CRACH24ML****

3.75 (95.3)

4.25 (108.0)

13.00 (330.2)

21.00 (533.4)

Single

MCB

CH

125

22

No

RACH24L125J

CRACH24ML****

3.75 (95.3)

4.25 (108.0)

13.00 (330.2)

21.00 (533.4)

Single

MLO

CH

125

24

No

1

RBCH24B200_

CRBCH24CS****

3.75 (95.3)

6.00 (152.4)

13.00 (330.2)

29.00 (736.6)

Single

MCB

CH

200

24

No

RBCH32L200_

CRBCH32ML****

3.75 (95.3)

6.00 (152.4)

13.00 (330.2)

29.00 (736.6)

Single

MLO

CH

200

32

No

1

RCCH32B200_

CRBCH32CS****

3.75 (95.3)

6.00 (152.4)

13.00 (330.2)

34.00 (863.6)

Single

MCB

CH

200

32

No

1

Notes
1 Catalog numbers shown with "_" at the end need one of the following suffixes to denote depth:
J = 3.75–4.25
K = 4.25–5.00
L = 5.00–6.00
Example: RBCH24B200J would signify an interior set with a depth range of 3.75 to 4.25 inches.
2 ****Denotes characters in the catalog number that relate to overall cover size.
Example: CRWCH6ML2620 would signify a cover 26.00 inches H x 20.00 inches W, or CRBCH24CS3324 would be 33.00 inches H x 24.00 inches W.
3 Amperes for MB panels is maximum; catalog number will reflect actual amperage of breaker included.

1
1
1

For UL applications, maximum cover sizes may apply.

1
1
1
1
1
1
1
1
1
V1-T1-20

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

1.1

Complete Assembly
Note: For complete assembly,
interior and cover need to be
ordered separately.

Adjustable Interior
●

●

●

●

Factory installed ground
and neutral bars positioned
to accept existing wires
Field adjustable depth
matches existing panel box
Adjustable height enables
optional placement of the
interior
Field bondable for service
entrance options

1

Standard Trim and Collar
●

●

●

1

Standard trim matches
new interior
New circuit directory for
updated labeling
Oversized collar eliminates
expensive wall/paint repair

1
1
1
1
1
1
1
1

Adjustable Interior

1

Collar and Assembly with Trim

1
Single-Phase—Main Lug Loadcenters, Non-Metallic
2460SNM

1

Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Neutral
Main
Ampere Rating
40 1
60

Maximum Number
1-Inch (25.4 mm)

Wire Size Range
Cu/Al 60°C or 75°C
for Main Lugs

1

Enclosure
Type

Trim Type

Box
Size

4

Indoor

Flush (no door)

2

4

4

Indoor

Surface (no door)

2

2

4

Indoor

Flush (no door)

2

2

4

Indoor

Surface (no door)

2

2460SNM

2

4

Indoor

Flush (no door)

2

2460FGNM 3

2

4

Indoor

Surface (no door)

2

2460SGNM 3

—

4

2460RNM

Spaces

Circuits

4

2

4

Outdoor

2

Loadcenter
Catalog Number

1

TT120FLGNM 23

1

TT120SLGNM 23
#14–2

2460FNM

1

Notes
1 Suitable for use as service equipment when not more than six main disconnecting means are provided and when not used as a lighting and appliance panelboard
(see Article 408.34 of the NEC).
2 This device has no main lugs. A Type BR or BD breaker is required to be backfed to supply power to branch breakers. This device is single-phase 120 Vac only.
With the use of three Type BR breakers, there are two branch circuits available. With the use of three Type BD breakers, there are five branch circuits available.
3 Includes GB4NM ground bar.
4 Includes a GFCB240 breaker, factory installed.

1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-21

1.1
1
1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

CH Loadcenter Options and Accessories
CHSF2125

Field Installation and Parts

1

Description

Ordering
Quantity 1

Catalog
Number

Sub-feed lug blocks—two-pole, 125A, 3/4-inch (19.1 mm) spaces needed

1

CHSF2125

1

Sub-feed lug blocks—three-pole, 125A, 3/4-inch (19.1 mm) spaces needed

1

CHSF3125

Neutral/ground lug—add-on neutral or ground lug

1

NL20

1

NL30

1

NL300

1

Filler plates—3/4-inch (19.1 mm) space circuit breaker space

25

CHFP

1

CSR main circuit breaker filler plate (with hardware)

1

CSRFP

Door lock—12–42 circuits, and 100–225A

1

TDL

Sandlewood spray paint

1

SPCSW

ANSI-61 light gray touchup paint for outdoor loadcenters

1

SPC61

Isolated neutral assembly (computer circuits)

1

BINA

Circuit directory—adhesive backed

10

TCD

1

Cover screws

25

LCCS

Cover replacement latch 14-5/16 inch (363.55 mm) wide loadcenters only

1

CHRLS

1

Circuit marking strip (next to breakers)

10

CHMS

Circuit identification label (preprinted breaker labels next to breakers)

25

CHBL

1

Series rated caution label

25

SRL

Branch circuit numbering strip

20

CHNS

1

Bonding strap with screw

1

BSSUSE

1

1

CHSF3125

CHFP

1

1

TDL

BINA

1
1

Note
1 Must be purchased in multiples of ordering quantities indicated.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
V1-T1-22

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

1.1

Mechanical Interlock Covers
Covers mechanically interlock two breakers. Type A covers
interlock two CH breakers mounted across from one another.
Type B covers interlock a main Type CSR breaker with a Type CH.
CH8BRM Type A

1
1
1

Mechanical Interlocks
Mechanical Interlock Trim/Deadfront Catalog Numbers

1

Type

Fits Loadcenter
Catalog Numbers

Flush

Surface

A

CH12L125B

CH8BFM

CH8BSM

1
1

CH16L125B
CH12L3125B
CH8EFM Type B

1

CH14B100B
CH8CFM

CH20L125C

CH8CSM

1

CH24L125C

1

CH18L3125C
CH24L3125C

1

CH22B100C
CH22N100C
CH8DFM

CH24L150D

1

CH8DSM

CH32L150D

1

CH24L3225D

1

CH30L3150D
CH8GFM

CH8GSM

Inner cover of Box B raintight

—

CH8BRM

Inner cover of Box C raintight

—

CH8CRM

CH24B150E

CHEFM

CHESM

1

CH8JFM

CH8JSM

1

CH42L225G

1

CH42L3225G

1

Indoor
B

CH24B200E
CH32B150J

1

CH32B200J
CH3242B200J

1

CH32N200J
CH32B225J
CH42B200K

CH8KFM

1

CH8KSM

1

CH42N200K
CH42B225K

1

Outoor
B

CH8B150RF

CH3RDF7M

—

1

CH8B200RF

1

CH8N200RF
CH24B150R

1

CH24B200R
CH32B150R

CH3RDF9M

—

CH3RDF10M

—

1

CH32B200R
CH32N200R

1

CH32B225R
CH42B200R

1

CH42N200R

1

CH42B225R

1
Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-23

1.1
1

CH8BRM Type A

Type CH Loadcenters and Circuit Breakers

Mechanical Interlocks, contiuned
Mechanical Interlock Trim/Deadfront Catalog Numbers

1

Type

1

Fits Loadcenter
Catalog Numbers

Flush

Surface

CHPC8B32LFM

—

CHPC8B42LFM

—

CH3RDF15M

—

CH3RDF16M

—

CH3RDF17M

—

CH3RDF18M

—

CH7JJFREPLM

—

CH7KKFREPLM

—

CH7LLFREPLM

—

Next Generation Power Center
B

1
1

Loadcenters and Circuit Breakers

CHPC32B150L
CHPC32B200L

CH8EFM Type B

CHPC32N200L
CHPC42B150L

1

CHPC42B200L
CHPC42N200L

1

CHPC32B125TR

1

CHPC32B150TR
CHPC32B200TR

1

CHPC32N200TR

1

CHPC42B200TR

1

CHPC32B150TR

CHPC42B150TR

CHPC42N200TR

CHPC32B200TR

1

CHPC42B200BR

1

Vintage 1
CH20JJM200

1

CH24JJM150

1

CH30JJM200

CH30JJM150

1

CH30JJM150H

1

CH304JJM150

CH3040JJMM200

CH304JJM200

1

CH304JJM200H

1

CH40KKM200H

CH30KKM225

1

CH40KKM225

1

CH40KKM225H

1

CH304KKM200H

CH40KKM200H

CH304KKM200

CH304LLM225

1

CH424LLM225H

1

Note
1 If vintage part number does not match exactly, the cover may not fit. Simple variations such as an “N” at the end of
the part number contain minor design variations that will prevent our cover from working with that particular loadcenter.

1
1
1
1
1
1
V1-T1-24

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

DS100H1

1.1

Field Installation Rainproof Conduit Hubs
Conduit Size

Catalog
Number

1

Description

Inches (mm)

Ordering
Quantity 1

Group 1—for use with 70, 100 and 125A MLO and MCB loadcenters and circuit breaker enclosures

0.75 (19.1)

1

DS075H1

1.00 (25.4)

1

DS100H1

1.25 (31.8)

1

DS125H1

1.50 (38.1)

1

DS150H1

2.00 (50.8)

1

DS200H1

2.00 (50.8)

1

DS200H2

2.50 (63.5)

1

DS250H2

3.00 (76.2)

1

DS300H2

Adapter kit—allows installing a Group 1 hub on devices arranged for Group 2 hubs

—

1

DS900AP

Group 1—small blank hub closure plate

—

1

DS900CP1

Group 2 —large blank hub closure plate

—

1

DS900CP2

Group 2—for use with 150, 200 and 225A MLO and MCB loadcenters and circuit breaker enclosures

1
1
1
1
1
1
1
1

GBK14

Ground Bar Kits
Length

1

Inches (mm)

Ordering
Quantity 2

dssssds

2.54 (64.5)

1

GBK5 2

dssssdsj

3.59 (91.2)

1

GBK520 2

dssssdssssss

4.29 (109.0)

1

GBK10 2

dssssdssssssj

5.34 (135.6)

1

GBK1020 2

1

4.61 (117.1)

1

GBK13

dssssdssssssssss

5.69 (144.5)

1

GBK14 2

dssssdssssssssssj

6.74 (171.2)

1

GBK1420 2

dssssdsssssssssssssssss

8.14 (206.8)

1

GBK21 2

dssssdsssssssssssssssssj

9.19 (233.4)

1

GBK2120 2

ssssssssdssssssdsssssss

7.94 (201.7)

1

CH9GP21

34

Ground Bar Legend
s = (3) #14–#10 Cu/Al or (1) #14–#4 Cu/Al
j = (1) #6–2/0 Cu/Al
= (1) 1/0–14 or (3) #10–12 Cu/Al
= (1) #14–1/0 Cu/Al or (3) #14–#10 Cu/Al
d = Mounting hole

f k

Catalog
Number 5

12–32 circuit main lug

CHGRD1

Split neutral kit for 22-circuit 125A maximum

CHSN125C

Main lug and CHH main breaker panels

CHGRD2

Split neutral kit for 32-circuit 200A maximum

CHSN225J

CC main CB panels

CHGRD3

Split neutral kit for 42-circuit 200A maximum

CHSN225K

Replacement neutral for all C type boxes

CHN125C

Replacement neutral for all D type boxes

CHN125D

Replacement neutral for all L type boxes

CHN225L

Isolated Neutral Assembly (computer circuits)

BINA

225

1
1

1
Neutral Bar Accessories
Description

125

1

1

Kit Catalog
Number 5

Three-Phase Loadcenter
Types of Panels

1

1

Grounded “B” Phase Adapters
Maximum
Amperes

1
1

2

f
d
f
f
f
k
f
d
f
k
f
f
f

Description (See Legend)

Catalog
Number

Notes
1 Must be purchased in multiples of ordering quantities indicated.
2 Distance between mounting holes is 1-3/4 inches (44.5 mm).
3 For single- and three-phase 400A loadcenters.
4 Distance between mounting holes is 2-13/32 inches.
5 Cannot be used in Safety Breaker Panels. Classic Plus Panels only.

1
1
1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-25

1.1
1
1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Decorator Cover Accessory
●
For easy use with CH loadcenters mounted in living space
●
Easily wallpapered or painted to match any decor
●
Loadcenter accessory—exclusively from Eaton

1
1

Loadcenter Goof Collars
Don’t let an ugly drywall problem ruin a beautiful
electrical installation.
Eaton’s Goof Collar is designed to cover gaps between the
finished drywall and loadcenter enclosure. This is often
necessary when upgrading the electrical service and the drywall
surrounding the panel is damaged. The collar allows 2 inches of
overhang beyond the standard flush trim.

1
1

SCOTT
HAS
PHOTO

1
1
1
1

Now you see it …

… Now you don’t.

1

Decorator Cover Accessory 1

1

Corresponding Cover

Existing CH Loadcenter Cover

CH Goof Collars

CH8BF

CH8KDNB

Inches (mm)

1

Before

After

Catalog Number

CH8CF

Catalog Number

Height

Width

Loadcenter Cover

CH8KDND

21.00 (533.4)

19.00 (482.6)

CH8BF

CH8BFC1921

19.00 (482.6)

CH8CF

CH8CFC1926

19.00 (482.6)

CH8DF

CH8DFC1934

CH8KDNC

1

CH8DF/EF
CH8GF/JF

CH8KDNJ

26.00 (660.4)

1

CH8KF

CH8KDNK

34.00 (863.6)

Goof Collar

CH8EF

1

CHSUR8EF
39.00 (990.6)

1

19.00 (482.6)

CH8GF

CH8JFC1939

CH8JF
42.00 (1066.8)

1

19.00 (482.6)

CH8KF

CH8KFC1942

CHSUR8KF
44.00 (1117.6)

1

19.00 (482.6)

CH8LF

CH8LFC1944

CHSUR8LF

1

BR Goof Collars

1

Inches (mm)
Height

Width

BR Box Size

1

21.00 (533.4)

19.00 (482.6)

B1

BRB2GC2319

23.00 (584.2)

19.00 (482.6)

B2

BRB1GC2119

25.00 (635.0)

19.00 (482.6)

C1

BRC1GC2519

1

27.00 (685.8)

19.00 (482.6)

C2

BRC2GC2719

31.00 (787.4)

19.00 (482.6)

C4

BRC4GC3119

1

34.00 (863.6)

19.00 (482.6)

D1

BRD1GC3419

1

1
1

Catalog Number
Goof Collar

38.00 (965.2)

19.00 (482.6)

G1

BRG1GC3819

43.00 (1092.2)

19.00 (482.6)

L1

BRL1G4319

48.00 (1219.2)

19.00 (482.6)

L2

BRL2GC4819

Note
1 For goof collars not listed in the table, please contact the Lincoln Flex Center at
1-800-330-6479.

1
1
1
V1-T1-26

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

1.1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Dimensions

1

Approximate Dimensions in Inches (mm)
Residential/Commercial/Unit Enclosure—Box Sizes

1

Residential Loadcenter Knockout
Residential NEMA Type 1 Indoor and NEMA Type 3R
Outdoor Enclosures.

Note: Box sizes do not include covers/fronts.

1

Residential Loadcenters
Box Size

Height

Width

Depth

1

Knockouts for Box Sizes 5, 6, 7, 5R, 6R, 7R
Code

Diameter

5

9.50 (241.3)

4.50 (114.3)

3.13 (79.4)

A

0.50 (12.7)

6

11.38 (288.9)

6.88 (174.6)

3.39 (86.1)

B

0.50 (12.7)

0.75 (19.1)

—

—

0.50 (12.7)

0.75 (19.1)

1.00 (25.4)

—

NEMA Type 1 Indoor

—

—

1

—

1

7

13.00 (330.2)

11.00 (279.4)

3.69 (93.7)

C

B

16.75 (425.5)

14.31 (363.5)

3.88 (98.4)

D

0.50 (12.7)

0.75 (19.1)

1.00 (25.4)

1.25 (31.8)

0.75 (19.1)

1.00 (25.4)

1.25 (31.8)

—

C

21.00 (533.4)

14.31 (363.5)

3.88 (98.4)

E

D

29.13 (739.8)

14.31 (363.5)

3.88 (98.4)

F

0.75 (19.1)

1.00 (25.4)

1.25 (31.8)

1.50 (38.1)

E

29.13 (739.8)

14.31 (363.5)

3.88 (98.4)

G

1.00 (25.4)

1.25 (31.8)

1.50 (38.1)

—

G

34.13 (866.8)

14.31 (363.5)

3.88 (98.4)

H

1.00 (25.4)

1.25 (31.8)

1.50 (38.1)

2.00 (50.8)

J

34.13 (866.8)

14.31 (363.5)

3.88 (98.4)

I

1.25 (31.8)

1.50 (38.1)

2.00 (50.8)

—

K

37.00 (939.8)

14.31 (363.5)

3.88 (98.4)

L

39.00 (990.6)

14.31 (363.5)

3.88 (98.4)

N

45.00 (1143.0)

14.31 (363.5)

3.88 (98.4)

9.50 (241.3)

4.50 (114.3)

3.13 (79.4)

6R

11.75 (298.5)

6.50 (165.1)

4.50 (114.3)

7R

13.00 (330.2)

11.00 (279.4)

3.69 (93.7)

B

16.75 (425.5)

14.31 (363.5)

5.19 (131.8)

C

21.00 (533.4)

14.31 (363.5)

5.19 (131.8)

D

29.13 (739.8)

14.31 (363.5)

5.19 (131.8)

E

29.13 (739.8)

14.31 (363.5)

5.19 (131.8)

G

34.13 (866.8)

14.31 (363.5)

5.19 (131.8)

J

34.13 (866.8)

14.31 (363.5)

5.19 (131.8)

K

37.00 (939.8)

14.31 (363.5)

5.19 (131.8)

L

39.00 (990.6)

14.31 (363.5)

5.19 (131.8)

1
F

1

Hub

A

1

A

D

D

F

D

D

D

A

B
A

F

1

Box 5R

1
Hub

A

C

F

B

Depth

1

A

B

H

1

D

A

F

A

Box 5

A

Width

A

A

D

Commercial Loadcenters
Height

B

F

C

1

F

1
A

D

F

F

1

D

B

NEMA Type 1 Indoor
A

P

54.38 (1381.1)

21.00 (533.4)

6.00 (152.4)

PM

62.63 (1590.7)

21.00 (533.4)

6.00 (152.4)

B

Width

B C

23.25 (590.6)

G

8.88 (225.4)

4.50 (114.3)

9.31 (236.5)

5.44 (138.1)

B

A

G

1

B

H

B

1

Box 6R

B B

1

Hub

A A A

1

B B

G

B
A

C

NEMA Type 3R Outdoor
23.69 (601.7)

A A A

Depth

NEMA Type 1 Indoor

A

H

Box 6

Types ECB and ECC Unit Enclosures
Height

1
1

Knockout Positions

F

Box Size

1
1

NEMA Type 3R Outdoor
5R

1

G

B

C
C
A A A

B C

F
G

A A A
A

Box 7

B B

1

C
G

G

F

C
A A A

B C

G

1

G

A A A
A

1

B B

Box 7R

1
1

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-27

1.1
1
1
1
1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Approximate Dimensions in Inches (mm)
Residential and Commercial Loadcenter Knockout
Residential NEMA Type 1 indoor and NEMA Type 3R outdoor enclosures.
Knockouts for Box Sizes 8, 8R, P, PM, B, C, D, E, G, J, K, L, N
and Outdoor Boxes 12–60 Circuits

Type ECB and ECC Unit Enclosure Knockout
Code

Diameter

Code

Diameter

a

0.75 (19.1)

—

—

—

—

b

0.50 (12.7)

0.75 (19.1)

—

—

—

1

c

0.50 (12.7)

—

—

—

—

NEMA Type 3R Outdoor

1

d

1.00 (25.4)

1.25 (31.8)

1.50 (38.1)

2.00 (50.8)

2.50 (63.5)

A

0.50 (12.7)

e

1.25 (31.8)

1.50 (38.1)

2.00 (50.8)

2.50 (63.5)

—

B

1.25 (31.8)

1

f

0.75 (19.1)

1.25 (31.8)

1.50 (38.1)

2.00 (50.8)

—

g

0.50 (12.7)

0.75 (19.1)

1.00 (25.4)

—

—

1

h

1.50 (38.1)

2.00 (50.8)

2.50 (63.5)

—

—

i

0.50 (12.7)

0.75 (19.1)

1.00 (25.4)

1.25 (31.8)

1.50 (38.1)

1

j

1.00 (25.4)

1.25 (31.8)

1.50 (38.1)

—

—

1

k

1.25 (31.8)

1.50 (38.1)

2.00 (50.8)

—

—

m

0.75 (19.1)

1.00 (25.4)

1.25 (31.8)

1.50 (38.1)

2.00 (50.8)

n

0.75 (19.1)

1.00 (25.4)

1.25 (31.8)

1.50 (38.1)

—

p

2.00 (50.8)

2.50 (63.5)

—

—

—

1

1
1
1

NEMA Type 1 Indoor (Flush and Surface Trims)
A

0.50 (12.7)

—

—

—

—

B

1.25 (31.8)

1.50 (38.1)

1.75 (44.5)

2.00 (50.8)

2.50 (63.5)

—

—

—

—

1.50 (38.1)

1.75 (44.5)

2.00 (50.8)

2.50 (63.5)

NEMA Type 1—Indoor
A

B

B

B

B

B

B

B

Knockout Diagram

B

A

b

c

1

h

NEMA Type 3R—Outdoor

1

HUB

1
1

c c
c
i
c

d

c

Flush
Trim

3/4

b

B

b

Outdoor Boxes
12–42 Circuits 225A Maximum

0.45 Dia.

1

i
b

c

c

c

c

d

c

c

c

c

g

g

c

e

e

Box P, PM

0.45 Dia.

c

b

1

1

e

c

0.45 Dia.

b b c c
c
g c c c

1

1

c

0.45 Dia.

1

1

c

a

1

1

e

e

e

0.45 Dia.

b

b

b

c

g

b

c

i

e

e

e

B

d

c

c

c

g

g

c

e

b

b

c

g

g

g

c

b

b

b

b

b

c
c
c

b

g

g
e

e

e

0.45 Dia.
b
g

0.45 Dia.

b c c
c

c

c
c

Box B

1

c

c

d

c
c

e

b
i

c

b

A

e

e

g

c
c

B

0.45 Dia.
c

c

c
c

c

B

g

c
c
c
c

b

b

b

b

c
c

b

b

b

b

c
c

g

g
e

e

e

0.45 Dia.

0.45 Dia.

b

b c c

g

c

c
c

e

c

c

c

d
c

b
i

c
c

b

Box C, D, E, G, J, K, L, N

1
1
V1-T1-28

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

1.1

Technical Data and Specifications
General
A. The Contractor shall
furnish and install
loadcenters incorporating
circuit breakers of the
number, rating and type
as specified herein and
as shown on the
contract drawings.

Ratings
A. Loadcenters shall be
rated for 240 Vac and
shall have short-circuit
ratings as shown on the
drawings or as herein
scheduled, but not less
than 10,000 amperes
rms symmetrical.

B. The loadcenter and all
components shall be
designed, manufactured
and tested in accordance
with the latest applicable
standards of UL and
NEMA including:

B. Breakers shall be full
size and a minimum of
125A frame. Breakers
10 –125A trip size shall
take up the same pole
spacing.

4. Federal Spec
Classification W-C 375

C. Loadcenters shall be
labeled with a UL shortcircuit rating. When
series ratings are applied
with integral or remote
devices, a label shall be
provided. Series ratings
shall cover all trip ratings
of installed frames. It
shall state the conditions
of the UL series ratings
including:

5. UL 1699—all fault
interrupting

1. Size and type of
upstream device.

Qualifications
A. The manufacturer of the
loadcenter shall be the
manufacturer of the
circuit breaker within the
load center. All breakers
shall be full size.

2. Branch devices that
can be used.

1. UL 67—standards for
panelboards
2. UL 50—standards for
cabinets and boxes
3. UL 489—standards for
molded case circuit
breakers

B. For the equipment
specified herein, the
manufacturer shall be
ISO® 9000 certified.
C. The manufacturer of
this equipment shall have
produced similar
electrical equipment
for a minimum period
of seven (7) years.
Manufacturers
A. Eaton

3. UL series short-circuit
rating.
Construction
A. All interiors, with the
exception of the branch
circuit breakers shall be
completely factory
assembled with main
breakers, main lugs or
no main device.
B. Interiors shall be so
designed that circuit
breakers can be replaced
without disturbing
adjacent units and
without removing the
main bus connectors and
shall be so designed that
circuits may be changed
without machining,
drilling or tapping.
C. Physical means must
be provided to prevent
the installation of more
overcurrent devices than
that number for which
the enclosure was
designed. Full size
breakers are required.

Bus
A. Busbars for the main and
cross connectors shall be
of silver flash plated
copper construction in
accordance with UL
standards. Bussing shall
be braced to 65 kAIC.
B. Neutral bussing shall
have a suitable lug for
each outgoing feeder
requiring a neutral
connection of same
ampacity as branch.
Wiring/Termination
A. All wire connectors and
terminals shall be of the
anti-turn solderless type
and suitable for copper
or aluminum wire of the
sizes indicated. All
connectors shall meet
the “Requirements
for Wire Connectors
and Soldering Lugs”
UL 486B.
B. All loadcenters where
marked shall be suitable
for use with 60/75°C
rated wire.
Circuit Breakers
A. Circuit breakers shall
be molded case type,
3/4-inch (19.1 mm) wide
per pole. Multipole circuit
breakers shall be of a
stack pole design to
provide electrical phase
isolation and have an
internal common trip.
B. Each pole of the circuit
breaker will have inverse
time delay overload and
instantaneous shortcircuit protection by
means of both thermal
and magnetic sensors.
Circuit breakers shall be
quick-make/quick-break.

D. All circuit breakers shall
be operated by a toggletype handle and multipole
circuit breakers shall have
an internal common trip
mechanism. The circuit
breakers shall incorporate
trip mechanisms that are
mechanically trip-free
from the handle. The
handle position shall
provide good visual
trip indication.
E. Contacts shall be of nonwelding silver alloy.

1
1
1
1
1
1
1
1

F. All branch breaker
handles shall be of a
different color than the
case of the breaker.

1

G. All terminals shall be
listed for use with copper
or aluminum conductors.
Terminals shall be of the
box lug design. The
terminals shall meet
UL 486B requirements
and shall be suitable for
use with either 60° or
75°C wire.

1

H. Breakers shall be SWD
rated and/or HACR rated
as required.
I. Arc fault interrupting
circuit breakers, (AFC),
shall be provided on all
15 and 20A single-phase
120/240 Vac circuits
except those indicated as
remote controlled
breakers. AFI breakers
shall be “Classified for
mitigating the effects of
arcing faults,” or
conforming to UL
Standard 1699 and as
defined by per Article
210.12 Section A of the
NEC Code.

C. The circuit breaker
calibration shall not be
affected by environmental
changes in relative
humidity. Breakers
shall be calibrated
after assembly.

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

V1-T1-29

1.1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Enclosures
A. Loadcenters shall have
NEMA 1 general purpose
or NEMA 3R rainproof
enclosures as indicated
on the drawings and
shall be surface or flush
mounted except where
noted.
B. For indoor applications,
enclosures shall be rated
NEMA 1. Enclosures
shall be manufactured
from cold-rolled codegauge sheet steel having
multiple knockouts
and painted per paint
specification. For outdoor
applications, enclosures
shall be rated NEMA 3R.
Enclosures shall be
manufactured from
galvanized steel which
shall be painted per the
painted as specified.
Enclosures shall be of
sufficient size to meet
or exceed NEC wire
bending space.

Finish
A. Boxes and trims shall
be finished with a
high scratch-resistant
aesthetically pleasing
finish. The finish shall
be polyurethane coating
electrostatically applied
to a thickness of 1.8 to
2 mils.
All loadcenters shall be
provided with provisions for
accepting a paintable or wall
paperable decorator accessory
cover. Where loadcenters are
installed in living areas, provide
manufacturer designed and
tested decorator cover kits.

C. The cover shall have an
easy adjustment feature
for flush applications.
D. Boxes shall be factory
assembled into a single
rigid structure.
E. Provide circuit breaker
marking labels and
directories.

1
1
1
1
1
1
1
1
1
1
1
1
V1-T1-30

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

1.1

Contents

Plug-On Circuit Breakers

Description
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CH Specialty Products. . . . . . . . . . . . . . . . . . . . . .
CH Loadcenter Options and Accessories . . . . . . .
CH Circuit Breakers
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
Options and Accessories . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . .
Wiring Diagrams. . . . . . . . . . . . . . . . . . . . . . . .

Page

1

V1-T1-2
V1-T1-14
V1-T1-22

1

V1-T1-32
V1-T1-38
V1-T1-40
V1-T1-40

1
1
1
1
1
1
1
1
1

CH Circuit Breakers
Product Description
Quick-make, quick-break
switch mechanism combined
with inverse time element
tripping operation and tripfree handle design. Type CH
circuit breakers trip to the
OFF position, eliminating
nuisance callbacks. The CHF
family also includes a trip flag
to differentiate between a trip
and the breaker being turned
off. The thermal-magnetic trip
curve avoids nuisance tripping
on mild overloads while
reacting almost instantaneously
to severe short-circuit
conditions. Multipole breakers
have internal common trip
connection to operate all
poles simultaneously. Handles
are marked with ON-OFF
indication and ampere rating
of the breaker.
Special Application Plug-On
Circuit Breakers—Type CH
10 kAIC 120 Vac and 120/240 Vac
Branch Feeder Type Arc
Fault Circuit Breakers
A branch feeder type arc fault
circuit interrupter is a device
intended to mitigate high
current arcing faults in the
complete circuit, including
connected cords. High
current arcing faults can
occur from line to neutral or
line to ground. These arcing
faults are in parallel with the
load and produce the most
energy of all arcing faults.

The branch feeder type AFCI
is required in the 1999 and
2002 National Electrical Code.
The Combination Type AFCI
is required in all subsequent
editions of the National
Electrical Code.
Combination Type Arc
Fault Circuit Breakers
A combination type arc fault
circuit interrupter is a device
that offers mitigation of high
current arcing faults in the
complete circuit, including
connected cords. In addition it
provides direct detection of
persistent low current arcing
faults down to 5 amps with
associated mitigation of
fire hazards in the cords
connected to the outlets. High
current arcing faults can occur
from line to neutral or line to
ground. These arcing faults
are in parallel with the load
and produce the most energy
of all arcing faults. The current
level of low current arcing
faults is limited by the load.
Ground Fault Circuit
Breakers—Ground Fault
Application Notes
Single-pole Type CHGFIs are
designed for use in two-wire,
120 Vac circuits. The diagram
on Page V1-T1-40 shows a
typical wiring configuration.

Two-pole Type CHGFIs are
designed for use in threewire, 120/240 Vac circuits,
120 Vac multiwire circuits
employing common, neutral
and two-wire, 240 Vac
circuits obtained from a
120/240 Vac source.
Diagrams on Page V1-T1-40
illustrate typical wiring
configurations for 120/240 Vac
multiwire circuits.
The diagram on Page
V1-T1-40 depicts a 240 Vac,
two-wire circuit. Note the
“panel neutral” conductor
connects to the neutral bar,

even though the neutral is not
included in the load circuit.
This connection is necessary
to supply a 120 Vac power
source to the ground fault
sensing circuit.
The figures are shown with
a 120/240 Vac, single-phase,
three-wire power source,
but are also applicable to a
120/208 Vac, three-phase,
four-wire power supply.
For all figures, the electrical
operation of the Type CHGFI
is not affected by the
equipment ground.

1
1
1
1
1
1
1
1
1
1

Features
Over-Center
Toggle Spring

Magnetic
Armature

1
1
Current
Bi-Metal

Latch
Lever

Lug
Screw
Latch
Spring
Load
Terminal

1
1
1
1
1

Line
Contact
Clip

1

Contact

1

Magnetic
Pole Piece

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-31

1.1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

1

Product Selection

1

10 kAIC, 120 Vac, 120/240 Vac and 240 Vac

1

Type CH Plug-On
Circuit Breakers

Type CH Breakers, 3/4-Inch (19.1 mm) per Pole 120, 120/240 or 240 Vac, 10 kAIC
Catalog Number

1
1

Ampere
Rating

1

10

1

15

(1) #14–8 1
(2) #14–10 12
(1) #14–6 3

25
30

1
1

Two-Pole 120/240 Vac
Common Trip Requires Two
3/4-Inch (19.1 mm) Spaces
5 per Shelf Carton

Three-Pole 240 Vac
Common Trip Requires Three
3/4-Inch (19.1 mm) Spaces
5 per Shelf Carton

CH110

CH210

CH310

CH115 78

CH215 8

CH315 8

CH120

78

CH220

8

CH320 8

CH125

8

CH225

8

CH325 8

CH130

8

CH230

8

CH330 8

8

CH235

8

CH335 8

Wire Size
Range Cu/Al
60ºC or 75°C

20

1

Single-Pole 120/240 Vac
Requires One
3/4-Inch (19.1 mm) Space
10 per Shelf Carton

1

35

#14–2
#14–6 3

CH135

40

#10–1/0 4
#14–2 5
#3/0 6

CH140 8

CH240 8

CH340 8

CH145

8

CH245

8

CH345 8

8

CH250

8

CH350 8

1

45
50

CH150

1

60

CH160

CH260

CH360

70

CH170

CH270

CH370

1

80

—

CH280

CH3080

90

—

CH290

CH3090

1

100

—

CH2100

CH3100

1

110

—

CH2110

—

125

—

CH2125

—

1
1

Type CH Plug-On
Circuit Breakers

CHF Breakers with Mechanical Trip Flag
Catalog Number

1
1

Ampere
Rating

1

10
15

1

(1) #14–8 1
(2) #14–10 12

25
30

1

35

1

45

40

50

1

Two-Pole 120/240 Vac
Common Trip Requires Two
3/4-Inch (19.1 mm) Spaces
5 per Shelf Carton

CHF110

CHF210

Wire Size
Range Cu/Al
60ºC or 75°C

20

1

Single-Pole 120/240 Vac
Requires One
3/4-Inch (19.1 mm) Space
10 per Shelf Carton

#14–2

1

#10–1/0
#14–2 5

4

CHF115 78

CHF215 8

CHF120

78

CHF220 8

CHF125

8

CHF225 8

CHF130

8

CHF230 8

CHF135

8

CHF235 8

CHF140

8

CHF240 8

CHF145 8

CHF245 8

CHF150 8

CHF250 8

Notes
1 For single- and two-pole breakers.
2 Solid and stranded wire can be used together.
3 For three-pole breakers.
4 Single-pole 60–70A, two-pole 80–125A, three-pole 40–100A.
5 Single-pole 40–50A, two-pole 40–70A.
6 Two-pole 150A.
7 Switching duty rated.
8 HACR rated.

1
1
1
1

For factory-installed options, refer to Page V1-T1-39.

1
V1-T1-32

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

1.1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Plug-On Branch Feeder Type Arc Fault Circuit Breakers, Type CH 10 kAIC, 120 Vac and 120/240 Vac

Type CH AFCI SinglePole Circuit Breaker

1
1

Combination Type CH AFCI 3/4-Inch (19.1 mm) Wide Circuit Breakers
Poles

Ampere Rating

Catalog Number

Single-pole
10 kAIC

15

CHFCAF115

20

CHFCAF120

Two-pole
10 kAIC

15

CHCAF215

20

CHCAF220

1

Standard Pigtail

1
1
1
1

Type CH AFCI SinglePole Circuit Breaker

1

Branch Type CH AFCI 3/4-Inch (19.1 mm) Wide FIRE-GUARD® Circuit Breakers
Poles

Ampere Rating

Configuration

Catalog Number

Single-pole
10 kAIC

15

AFCI

CH115AF 1

20

AFCI

CH120AF

1

15

AFCI common trip

CH215AF

20

AFCI common trip

CH220AF

Two-pole
10 kAIC 23

1
1
1
1
1
1
1

Plug-On Combination Type Arc Fault Circuit Breakers and Ground Fault, Type CH 10 kAIC, 120 Vac and 120/240 Vac 4
Type CH AFCI SinglePole PON Combo
Circuit Breaker

1

Combination Type CH AFCI 3/4-Inch (19.1 mm) and CHGFCI Circuit Breakers
Poles

Ampere Rating

Configuration

Catalog Number

Single-pole
10 kAIC

15

AFCI plug-on neutral

CHFCAF115PN

20

AFCI plug-on neutral

CHFCAF120PN

15

GFCI plug-on neutral

CHFGF115PN

20

CHFGF120PN

25

CHFGF125PN

30

CHFGF130PN

1
1
1
1
1
1

Notes
1 Clamshell packaging available with CS modification code on the end of catalog number.
2 Common trip refers to two-pole 240V load application sourced by 120/240 Vac (see diagram on Page V1-T1-40).
3 Independent trip refers to two-pole multi-wire, home run or shared neutral circuits (see diagrams on Page V1-T1-40).
4 Requires plug-on neutral loadcenter.

1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-33

1.1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

1

Plug-On Ground Fault Circuit Breakers, Type CH 10 kAIC, 120 Vac and 120/240 Vac

1

Type CH Single-Pole

Type CH Ground Fault Circuit Breakers (5 Milliampere) 3/4-Inch (19.1 mm) per Pole 120 Vac or
120/240 Vac,10 kAIC
Catalog Number—1 per Shelf Carton

1
1

Single-Pole 120 Vac Requires
One 3/4-Inch (19.1 mm) Space

Two-Pole 120/240 Vac Common Trip
Requires Two 3/4-Inch (19.1 mm) Spaces

Ampere
Rating

Wire Size Range
Cu/Al 60ºC or 75°C 1

15

#14–6

CHFGF115

CH215GF

1

20

#14–6

CHFGF120

CH220GF

1

25

#14–6

CHFGF125

CH225GF

30

#14–6

CHFGF130

CH230GF

1

35

#14–6

—

CH235GF

40

#14–6

—

CH240GF

1

45

#14–6

—

CH245GF

50

#14–6

—

CH250GF

60

#14–6 1

—

CH260GF

1

1
1

Type CH Two-Pole

Type CH Ground Fault Equipment Protectors (30 Milliampere) 3/4-Inch (19.1 mm) per Pole 120 Vac or
120/240 Vac, 10 kAIC

1

Catalog Number—1 per Shelf Carton

1

Single-Pole 120 Vac Requires
One 3/4-Inch (19.1 mm) Space

Two-Pole 120/240 Vac Common Trip
Requires Two 3/4-Inch (19.1 mm) Spaces

CH215EPD

1

Ampere
Rating

Wire Size Range
Cu/Al 60ºC or 75°C 1

1

15

#14–6

CHFEP115

20

#14–6

CHFEP120

CH220EPD

1

25

#14–6

CHFEP125

—

30

#14–6

CHFEP130

CH230EPD

1

40

#14–6

—

CH240EPD

1

50

#14–6

—

CH250EPD

60

#14–6 1

—

CH260EPD

1
1

Type CH Switching Neutral Breakers—10 kAIC, 120 Vac and 120/240 Vac
Used to open the neutral along power line(s) for applications of gas pumps.

1

CH220SW

3/4-Inch (19.1 mm) per Pole 120/240 or 240 Vac, 10 kAIC
Catalog Number—1 per Shelf Carton

1

Two-Pole 120 Vac
Common Trip Requires
Two 3/4-Inch (19.1 mm) Spaces

1
1
1
1

Wire Size Range
Cu/Al 60ºC or 75°C

15

#14–8

CH215SW 2

CH315SW 3

20

#14–8

CH220SW 2

CH320SW 3

#14–8

CH230SW

2

CH330SW 3

CH240SW

2

CH340SW 3

CH250SW

2

CH350SW 3

40
50

1

#14–8
#14–8

Notes
1 60A breaker listed for 75°C Cu wire only.
2 For circuit breakers with shunt trip, add ST suffix. Shunt trip requires one additional pole space.
3 Switching duty rated.

1
1
V1-T1-34

Phase
Phase
Neutral Out
Neutral In

Ampere
Rating

30

1

(Hot leg)
Neutral Out
Neutral In

Three-Pole 120/240 Vac
Common Trip Requires
Three 3/4-Inch (19.1 mm) Spaces

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

1.1

Type CH-HID Circuit Breakers—10 kAIC, 120 Vac, 120/240 and 240 Vac
Suitable for use in circuits for fluorescent and high intensity discharge lighting. Also suitable for HACR applications.

1
1

3/4-Inch (19.1 mm) per Pole 120 Vac, 120/240 and 240 Vac, 10 kAIC
Single-Pole 120/240 Vac
Requires One
3/4-Inch (19.1 mm) Space

Two-Pole 240 Vac
Common Trip Requires
Two 3/4-Inch (19.1 mm) Spaces

Three-Pole 240 Vac
Common Trip Requires
Three 3/4-Inch (19.1 mm) Spaces

10 per Shelf Carton
Catalog Number

5 per Shelf Carton
Catalog Number

5 per Shelf Carton
Catalog Number

1
1
1

Ampere
Rating

Wire Size Range
Cu/Al 60ºC or 75°

15

#14–8

CH115HID

CH215HID 1

CH315HID

20

#14–8

CH120HID

CH220HID

CH320HID

30

#14–8

CH130HID

CH230HID

CH330HID

1
1
1
1

Type CHT Twin 10 kAIC, 120/240 Vac, Universal CTL and Non-CTL Plug-On Circuit Breakers
Suitable for CTL and Non-CTL CH loadcenters.
Type CH and CHT
Circuit Breakers
Mounted in Twin
Breaker Panel

1

Twin (CTL) 3/4-Inch (19.1 mm) per Pole 120 Vac Class CTL 10 kAIC
Single-Pole Requires
One 3/4-Inch (19.1 mm) Space

1

10 per Shelf Carton
Catalog Number

1

Ampere
Rating

Wire Size Range
Cu/Al 60ºC or 75°C

15–15

#14–8

CHT1515 23

15–20

#14–8

CHT1520 23

#14–8

23

20–20

1

120/240 Vac
120/240 Vac

CHT2020

1
1

Notes
1 CH215HID is rated for 120/240V.
2 Switching duty rated.
3 HACR rated.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-35

1.1
1
1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

Type CHP Commercial Breakers—10 kAIC, 120 Vac, 120/240 Vac and 240 Vac
Note: CHP breakers feature on-off and trip positions for commercial applications.

3/4-Inch (19.1 mm) per Pole 120, 120/240 or 240 Vac, 10 kAIC

1
1
1
1
1
1
1
1

Ampere
Rating

Wire Size Range
Cu/Al 60ºC or 75°C

10

(1) #14–8 1
(2) #14–10 12
(1) #14–6 3

Single-Pole 120/240 Vac
Requires One 3/4-Inch
(19.1 mm) Space

Two-Pole 120/240 Vac
Common Trip
Requires Two 3/4-Inch
(19.1 mm) Spaces

Three-Pole 240 Vac
Common Trip
Requires Three 3/4-Inch
(19.1 mm) Spaces

10 per Shelf Carton
Catalog Number

5 per Shelf Carton
Catalog Number

5 per Shelf Carton
Catalog Number

CHP110

CHP210

CHP310

CHP115 67

CHP215 7

CHP315 7

20

CHP120 67

CHP220 7

CHP320 7

25

CHP125 7

CHP225 7

CHP325 7

30

CHP130

7

CHP230

7

CHP330 7

7

CHP235

7

CHP335 7

15

1

35

#14–2
#14–6 3

CHP135

40

#10–1/0 4
#14–2 5

CHP140 7

CHP240 7

CHP340 7

7

7

CHP345 7

1

45

1

50

CHP150 7

CHP250 7

CHP350 7

60

CHP160 7

CHP260 7

CHP360 7

1

70

CHP170

CHP270

CHP370

80

—

CHP280

—

1

90

—

CHP290

—

100

—

CHP2100

CHP3100

110

—

CHP2110

—

125

—

CHP2125

—

1
1
1
1
1

CHP145

Type CHP-GFCI Circuit Breakers—10 kAIC, 120 Vac and 120/240 Vac
Note: CHP breakers offer on-off and trip positions for commercial applications.

5 Milliampere—3/4-Inch (19.1 mm) per Pole
120V and 120/240 Vac, 10 kAIC
Single-Pole 120 Vac Requires
One 3/4-Inch (19.1 mm) Space

1

1 per Individual Carton
Catalog Number

1
1

Ampere
Rating

Wire Size Range
Cu/Al 60ºC or 75°C

1

15

#14–6

CHP115GF

20

#14–6

CHP120GF

30

#14–6

CHP130GF

1
1
1
1
1

CHP245

Notes
1 For single- and two-pole breakers.
2 Solid and stranded wire can be used together.
3 For three-pole breakers.
4 Single-pole 60–70A, two-pole 80–125A, three-pole 40–100A.
5 Single-pole 40–50A, two-pole 40–70A.
6 Switching duty rated.
7 HACR rated.
CHP breakers offer on-off and trip positions for commercial applications.

1
1
V1-T1-36

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

1.1

Type CHP Neutral Switching Breakers—10 kAIC, 120 Vac and 120/240 Vac
Used to open the neutral along power line(s) for applications of gas pumps.

1
1

3/4-Inch (19.1 mm) per Pole 120 or 120/240 Vac, 10 kAIC
Two-Pole 120 Vac Common Trip
Requires Two 3/4-Inch (19.1 mm) Spaces

Three-Pole 120/240 Vac Common Trip
Requires Three 3/4-Inch (19.1 mm) Spaces

1 per Shelf Carton
Catalog Number

1 per Shelf Carton
Catalog Number

1
1
1

Phase
Phase
Neutral Out
Neutral In

(Hot leg)
Neutral Out
Neutral In

Ampere
Rating

Wire Size Range
Cu/Al 60ºC or 75°C

15

#14–8

CHP215SW 1

CHP315SW 1

20

#14–8

CHP220SW 1

CHP320SW 1

1
1

Type CH-M50 High Ambient Breaker

1

3/4-Inch (19.1 mm) per Pole 120 or 120/240 Vac, 10 kAIC

1

Single-Pole 120/240 Vac
Requires One 3/4-Inch (19.1 mm) Space

Two-Pole 120/240 Vac Common Trip
Requires Two 3/4-Inch (19.1 mm) Spaces

1

10 per Shelf Carton
Catalog Number

5 per Shelf Carton
Catalog Number

1

CH115M50

CH215M50

CH120M50

CH220M50

25

CH125M50

CH225M50

30

CH130M50

CH230M50

35

CH135M50

CH235M50

40

CH140M50

CH240M50

45

CH145M50

CH245M50

50

CH150M50

CH250M50

60

—

CH260M50

70

—

CH270M50

Ampere
Rating

Wire Size Range
Cu/Al 60ºC or 75°C

15

(1) #14–8
(2) #14–10

20

1
1
1
1
1
1
1

Type CH-HM and CHP-HM High Magnetic Breakers

1

3/4-Inch (19.1 mm) per Pole 120 or 120/240 Vac, 10 kAIC

1

Single-Pole 120/240 Vac
Requires One 3/4-Inch (19.1 mm) Space

Two-Pole 120/240 Vac Common Trip
Requires Two 3/4-Inch (19.1 mm) Spaces

1

10 per Shelf Carton
Catalog Number

5 per Shelf Carton
Catalog Number

1

Ampere
Rating

Wire Size Range
Cu/Al 60ºC or 75°C

15

(1) #14–8
(2) #14–10

CH115HM

CH215HM

CH120HM

CH220HM

(1) #14–8
(2) #14–10

CHP115HM

CHP215HM

CHP120HM

CHP220HM

20
15
20

1
1
1
1

Note
1 For circuit breakers with shunt trip, add ST suffix. Shunt trip requires one additional pole space, obtain pricing from Page V1-T1-39.

1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-37

1.1
1
1

CHHT

Field Installation Kits and Parts
Description

1

Handle tie bar for physically joining the handles of two adjacent single-pole Type CH circuit breakers (molded plastic handle cover)
CHPL

CHHT

CHPLGF

Padlockable device for locking the handle of single-, two- or three-pole Type CH circuit breakers (escutcheon mounted) 5

1

CHPL

1

CHPLGF

Padlockable device for locking the handle of main circuit breaker Types CC and CCH into the ON or OFF position.(screw mounted) 6

1

CCPL

mounted) 5

1

MCBPL

10

CHLO

Hold-down retainer kit for single-, two-, three-pole Type CH circuit breakers. For 6–24 circuit 125A single- and three-phase,
12–42 circuit single-phase 225A and 24–42 circuit three-phase 225A MLO Type CH loadcenters

1

CH125RB

Hold-down retainer kit for single-, two-, three-pole Type CH circuit breakers for 2–4 circuit MLO CH loadcenters.

1

CH125RB24

1

CH9MB270

Padlockable device for locking the handle of main breaker Types BW and CSR into the ON or OFF position (escutcheon

1

Hold-Down Kits 9

Device used to secure handle in ON or OFF position for single-pole Type CH circuit breakers (handle mounted) 8
MCBPL

1

Mounting Bases
CHLO

Mounting base for two-pole Type CH circuit breaker—70A maximum
Main Breaker Lug Kits

1
1

25

Padlockable device for locking the handle of a single-, two- or three-pole Type CHGFI circuit breaker (escutcheon mounted) 5

1

1

Catalog
Number

Handle Lockoffs 34

Handle Lockdogs 47

1

Ordering
Quantity 1

Handle Ties 2

1
1

Type CH Loadcenters and Circuit Breakers

Options and Accessories

1
1

Loadcenters and Circuit Breakers

CH125RB

Types CC and CCH main breaker lug kit (2) 300 kcmil

1

CCL300

Type CSR main breaker lug kit (2) 300 kcmil

1

MCBL300

10

CHML

Mechanical Interlock
Type CH for two-, three- and four-pole breakers

1
1
1
1

CH9MB270

1
1
1
1

CHML

1
1
1

Notes
1 Must be purchased in multiples of ordering quantities indicated.
2 Handle ties: typically used to join two similar independent single-pole breakers to form a two-pole noncommon trip breaker.
3 Handle lockoffs: devices that use a padlock to lock the circuit breaker’s handle in the ON or OFF position.
4 Requires one additional pole space.
5 Escutcheon mounted: device mounted semipermanently to the face of the circuit breaker and secured by the loadcenter deadfront.
6 Screw mounted: device permanently mounted to the face of the circuit breaker by the use of a non-removable screw.
7 Handle lockdogs: devices that are used to secure a circuit breaker’s handle in the ON or OFF position. Handle lockdogs are not padlockable devices.
8 Handle mounted: device mounted above or below handle using spring pressure.
9 Hold-down kits: devices used to secure the circuit breaker to the loadcenter for back-feed main application. See NEC Article 384.16(g).

1
1
1
1
1
V1-T1-38

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

1.1

Shunt Trip Options
Description
Type

Volts

Catalog Number
Suffix Adder 1

CSR

12 DC

SR12

CSR

24 DC

SR24

CSR

120 AC

SR01

CH

120 AC

ST 2

CC

12 DC

SR12

CC

24 DC

SR24

CC

120 AC

SR01

CC

208 AC

SR08

CC

240 AC

SR02

1
1
1
1
1
1
1
1

Handle Position Changeability Chart

1

To Change Handle Position from
ON to OFF or OFF to ON You Must...
Handle Lockoff and
Lockdog Types

Remove
Padlock

Remove
Device

Remove Loadcenter
Deadfront

Lockoff escutcheon mounted

Remove

—

—

Lockoff screw mounted

Remove

—

—

Lockdog handle mounted

N/A

Remove

—

1
1
1
1

Notes
1 Add suffix indicated to end of breaker catalog number.
2 Requires one additional pole space.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-39

1.1

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

1

Technical Data and Specifications

1

Ratings
Single- and two-pole CH breakers rated 15 and 20A have
low instantaneous magnetic trip levels. The 15 and 20A
breakers with “HM” suffix have high magnetic trip settings
recommended for circuits with inherently high inrush currents.
All Type CH breakers are marked for heating, air conditioning
and refrigeration (HACR) equipment application. Single-pole
15–20A breakers are also suitable for switching duty (SWD).
Shunt trip coils operate on 120 Vac and require one additional
pole space per breaker.

1
1
1
1
1
1
1

Wiring Diagrams
Typical Single-Pole

Two-Pole 240V Load Application Sourced by 120/240 Vac

120/240 Vac
Source
N A B

120/240 Vac
Source
N A B

1
1

Line B

Line B

1

Two-Pole

Single-Pole
Neutral
Neutral

120V
Duplex
Receptacle

240V
Duplex
Receptacle

Line A
Neutral

1

Equipment Ground

1
1

Single-Pole 120V Load Application Sourced by 120/240 Vac

Two-Pole Shared Neutral with Duplex Receptacle Application

1

120/240 Vac
Source
N A B

120/240 Vac
Source
N A B

1

Line B

Line B
Line A

1
1

Neutral
Neutral

1
1
1

120V
Duplex
Receptacle

Neutral
Neutral

Equipment Ground

1
1

Two-Pole

Single-Pole

1

Two-Pole Shared Neutral with Multi-Duplex
Receptacle Application

Equipment Ground

Single-Pole 120V Duplex
Receptacle Application
120/240 Vac
Source
N A B

120/240 Vac
Source
N A B

Line B
Line B

1

Single-Pole

Two-Pole

1
1

120V Duplex
Receptacle
(With Line Side
Jumper Removed)

Neutral
Neutral

Neutral

Two 120V
Duplex
Receptacles

Neutral

120V
Duplex
Receptacle

Equipment Ground

1
Equipment Ground

1
V1-T1-40

Line A

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

Loadcenters and Circuit Breakers
Type CH Loadcenters and Circuit Breakers

1.1

Two-Pole 120V Multi-Duplex Receptacle Application

1

120/240 Vac
Source
N A B

1
1

Line B

1

Two-Pole
Neutral
Neutral

1

Two 120V
Duplex
Receptacles

1
1

Line A

1
Two-Pole 120V Duplex Receptacle Application

1

120/240 Vac
Source
N A B

1
1

Line B
Line A

1

Two-Pole
Neutral
Neutral

1

120V Duplex
Receptacle
(With Line Side
Jumper Removed)

1
1
1

Two-Pole 240V Duplex Receptacle Application

1

120/240 Vac
Source
N A B

1

Line B

1
1

Two-Pole
Line A
Neutral

240V
Duplex
Receptacle

1
1
1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-41

1.2
1

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Type BR Loadcenters and Circuit Breakers

Contents
Description

1

Overview
Product Description . . . . . . . . . . . . . . . . . . . . .
Features, Benefits and Functions . . . . . . . . . .
Standards and Certifications . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection. . . . . . . . . . . . . . . . . . . . . . .
BR Specialty Products
Spa Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Riser Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type BR Renovation Loadcenter . . . . . . . . . . .
Type BR Mechanical Interlock Kits . . . . . . . . . .
Type BR Retrofit Interior Kits . . . . . . . . . . . . . .
BR Circuit Breakers. . . . . . . . . . . . . . . . . . . . . . . .

1
1
1
1
1
1
1

Page
V1-T1-43
V1-T1-43
V1-T1-45
V1-T1-45
V1-T1-46
V1-T1-57
V1-T1-58
V1-T1-59
V1-T1-61
V1-T1-72
V1-T1-75

1
1

Overview

1

Product Selection Guide

1

BR Loadcenters

1

Description

1

Single-phase, three-wire, 120/240 Vac

1

Short-Circuit Current Rating

Service

1

10 kAIC: All single- and three-phase loadcenters 70–225A, 8 to 42 circuits
22 kAIC: All convertible loadcenters using 125A rated Type BRH main breakers or
selected factory installed 125A rated Type BRH main breaker

1

Main Breaker/Main Lug Loadcenters

1
1
1

Single-phase
Main breaker: 100, 125, 150, 200, 225, 400, 600A
Main lugs: 70, 125, 150, 200, 225, 400, 600A

Main breaker: single-phase up to 200A and three-phase up to 225A

1

Enclosures

1

NEMA Type 1 indoor
NEMA Type 3R outdoor

1

Loadcenter and Breaker Accessories

1
1
1

Three-phase
Main breaker: 100, 125, 150, 200, 225, 400, 600A
Main lugs: 100, 125, 150, 200, 225, 400, 600A

Main lugs: single-phase up to 200A and three-phase up to 150A

Branch Breakers

1

1

25 kAIC: All convertible and factory-installed single-phase loadcenters rated
150 and 200A using Type CSR main breakers

Convertible Loadcenters

Types BR, BRH and BRHH: 10–150A. single-, two- and three-pole; selected amperage
available in switching duty, HACR, shunt trip and high magnetic setting
Type GFCB: 15–60A
Types BJ and BJH: 125–225A; two- and three-pole
Type BD Twin: 10–50A; two of one-pole; take one 1-inch (25.4 mm) space

1

Three-phase, four-wire, 208Y/120 Vac
Three-phase, three-wire, 240 Vac delta

Type BQ and BQC Multibreaker: 15–30A. Two of two-pole or one two-pole and
two one-pole; takes two 1-inch (25.4 mm) spaces
Type BRW: 15–30A; two-pole water heater breakers
Type BRSN: 15–30A; two-pole switching neutral breakers
Type BR 15–100A; two-pole, 240 Vac delta breakers
BR-AFCI arc fault circuit interrupter

NEMA 4X
Meets or exceeds UL requirements for indoor or outdoor applications

Branch circuit breaker:
Auxiliary components
Hold-down kits Handle ties
Lockoffs
Lockdogs
Complete line of ground bar kits 5, 10, 14 and 21 circuit, some with additional #2/0 lugs;
each terminal will accommodate: (3) #14–#10 Cu/Al or (1) #14–#4 Cu/Al
Main and sub-feed lugs 125, 150, 225A—two- and three-pole
Shunt trips

Surge protection:
Single-phase plug-on surge protector
Single-phase bottle type surge protector
Three-phase bottle type surge protector
Single-phase whole home surge protector
Universal rainproof conduit hubs
Group One: 3/4, 1, 1-1/4, 1-1/2, 2 inches (19.1, 25.4, 31.8, 38.1, 50.8 mm)
Group Two: 2, 2-1/2, 3 inches (50.8, 63.5, 76.2 mm)
Adapter plate

Bussing
Tin-plated aluminum as standard

V1-T1-42

Limited copper bus panels available

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

1.2

Product Description
Loadcenters are enclosures
specifically designed to house
the branch circuit breakers
and wiring required to
distribute power to individual
circuits. They contain either a
main breaker when used at
the service entrance point or
a main lug when used as a
sub-panel to add circuits to
existing service. The main
breaker protects the main
entire panel and can be used
as a service disconnect. The
branch breakers protect the
wires leading to individual
electrical loads such as
fixtures and outlets.

Features, Benefits and
Functions
Loadcenter Construction
Eaton’s Type BR loadcenters
have standard tin-plated
aluminum bus with a limited
availability of copper bus.
The sum of the handle
ratings connected to any stab
is limited to 150A maximum
on the 100 and 125A
loadcenters, and 200A on
loadcenters with 150A or
higher main bus. NEMA
Type 1 boxes or enclosures
are manufactured from
galvanized steel. Raintight
boxes are manufactured
from galvanized steel, then
finished using an electrostatic
powder coat, baked urethane
paint process.
Neutrals
Eaton Type CH loadcenters
feature two types of neutrals:
Insulated/Bondable Split
Neutral
Panels are supplied with split
insulated neutrals with an
insulated cross strap. For
service entrance applications,
the neutral must be bonded
by using the bonding strap
supplied with the panel. For
non-service entrance (subpanel) applications, the panel
may be installed with the
bonding strap not connected
to the neutral. Separate
ground bars must be used on
non-service entrance panels.

Insulated/Bondable Single
Neutral
Panels are supplied with a
single insulated neutral. For
service entrance applications,
all that is required to bond the
neutral is to loosen the
bonding screw and the
neutral screw directly beside
it, insert the bonding strap
into the neutral bar, and retighten both connections. The
single neutral can be moved
by the contractor to the other
side of the panel, if desired.
When used as a service
entrance panel, unused
neutral connections may be
used for the termination of
equipment grounds. For nonservice entrance (sub-panel)
applications, the panel may
be installed with the bonding
strap not connected to the
neutral. Separate ground bars
must be used on non-service
entrance panels.
Grounds
In service entrance
applications where the
neutral is bonded, unused
neutral holes may be used
for terminating ground
conductors. In sub-feed
panels, the neutral must be
isolated (non-bonded), and
ground wires must be
terminated on a separate
ground bar.
The insulated/bondable
single/split neutral panels
have sufficient terminations
for both ground and neutral
conductors. The insulated/
bondable single split neutral
panels are supplied with a
separate factory-installed
ground bar if the catalog
number contains a “G.” If
not, a separate ground bar
should be installed. Insulated/
Bondable Single Neutral
panels are supplied without
a ground bar (unless
otherwise noted), and ground
bar kits if needed must be
purchased separately.

Neutral and Ground Terminals
The standard terminals on
grounds and neutrals are
rated to accept (3) #14–#10
Cu/Al or (1) #14–4, provided
the cables terminated are of
the same material. For larger
cables, add-on neutral lugs
may be ordered from the
accessories on Page
V1-T1-65.
Note: NEC allows only one
current-carrying conductor
per hole on neutrals unless
otherwise noted.

Bottom Fed Loadcenters
For single-phase 225A and
below loadcenters that are
bottom fed, a standard panel
can be rotated 180 degrees
to allow straight-in wiring of
power cables to the main
terminals. Because the main
circuit breaker handle
operates horizontally, the
orientation of the main circuit
breaker handle is consistent
with the requirements of NEC
2008 Article 240.81.
Gutter Splicing
Loadcenters are not UL listed
as wiring troughs. Therefore,
gutter splicing of riser cables
to tap off to the main device
is not permitted. Refer to
NEC 2008 Article 312.8.
Fire Rating
Due to the numerous
openings in both loadcenter
boxes and trims, they should
not be mounted in firewalls.
There is no approved method
for sealing the enclosures for
this application.

Date Code
The date of manufacture of
each loadcenter is printed on
the outside of the carton as
well as inside the loadcenter.
On the carton, the date code
is printed on the end carton
label. In the loadcenter, the
date code is located on the
small white label located on
the right side wall (with the
main device on top).

1
1
1
1
1
1

The date code is in the
following format: F # # # &.
The “F” is the numeric
code for the Lincoln, IL
plant, and the three numbers
are the year and week of
manufacturing, e.g., 023. The
“!” sign at the end signifies
the decade of the 2010.
Therefore, the date code
F023& would indicate
that the product was
manufactured in the 23rd
week of 2010. The 1980s
are represented by the “+”
sign and the 1990s are
represented by a “=”
at the end of the code.

1

Surge Protectors
Complete home surge
protection is available in
multiple options, including
a factory-installed option that
provides the highest level of
surge protection in a
residential design. See Tab 3
for more details.

1

Circuit Breaker Case
Interrupting Capacity
●
10 kAIC
●
22 kAIC
●
25 kAIC

1
1
1
1
1
1
1
1
1
1
1
1
1

Warranty Information
●
10-year limited
loadcenter warranty
●
10-year limited branch
breaker warranty

1
1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-43

1.2
1
1
1

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Type BR Loadcenter
Extra 1.5 inch Knockout
(38.1 mm)
■ Larger knockout provides
easier installation and time
savings

1
1
1

Top or Bottom Feed
■ Straight-in wiring saves labor
and material
■

1
1
1
1
1
1
1
1

“Tangential” Center Knockout
Easier installation for conduit
applications

■

Commercial Grade Main
Breaker
■ 25 kAIC series rated main
breaker for superior protection

One panel for either top or
bottom applications
Neutral Bus (Strap)
■

2/0 Lug
■ Easily removable and can be
installed in any location
on the neutral bar

Type BR AFCI Breakers
■ Compact design for easier
wiring and improved
wireway access
■

■

Optional LED indicates
one of six trip codes for
circuit diagnostics
Provides a clean gutter space

Is easily removable for
sub-panel applications

Bonding Z-Strap
Provides easy field
conversion for service
entrance applications

■

Twin Neutral Bars
Minimum 150% neutral
capacity

■

1
1
1
1

Standard Tin-Plated
Aluminum Bus
■ Excellent conductivity and
corrosion resistance
■

1
1
1

Copper bus options
available for select
catalog numbers

Drywall Marking on Enclosure
Indicates proper mounting
depth for flush applications

■

1

Single Keyhole Mounting
One keyhole at the top
and bottom provides easier
mounting and leveling

■

1
1
1
1

Steel Backpan
Provides solid and reliable
breaker mounting—single
piece design for stability and
durability

■

Warranty
10-year warranty on all
Type BR loadcenters and
circuit breakers.

1
1
1
1
V1-T1-44

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

1.2

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Standards and Certifications

Catalog Number Selection

UL Listings
All Eaton Type BR loadcenters
are listed under UL File
E52977 except the
2–8 circuit loadcenters,
up through and including
125A, which are listed under
UL File E8741.

Single- and Three-Phase Through 225A

1
3 BR

1

30 42 B C 200

1

Phase

Construction

Blank = Single-phase 1
3
= Three-phase

Blank = No feed thru lugs 1
F
= Feed-through lugs
G
= Ground bar
P
= Current design
NY = NY City gutter space

Main Device
B = Main breaker
L = Main lug
N = Convertible main
H = Main breaker high AIC

Eaton’s Type BR
Loadcenter
Factory Options
SUR = Factory integrated surge

Enclosure
= NEMA Type 3R rainproof
= NEMA Type 1 indoor with
surface trim
F
= NEMA Type 1 indoor with
flush trim
Blank = NEMA Type 1 indoor with
combination trim 1
RIS = Riser panel
R
S

Bus

Number of 1-Inch
(25.4 mm) Spaces

Blank = Aluminum bus 1
C
= Copper bus

Maximum Number
of Circuits

50
70
100
125

1
1
1
1
1
1
1
1

Amperes
= 50A
150 = 150A
= 70A
200 = 200A
= 100A
225 = 225A
= 125A

1
1
1

Single- and Three-Phase 400–600A

3 B 30 42 D F N
Phase
Blank = Single-phase 1
3
= Three-phase

1
1

N = Current design

Main
Blank = Main lug 1
B
= Main breaker

Amperes
D = 400A
E = 600A

Number of 1-Inch
(25.4 mm) Spaces
Maximum Number
of Circuits

1
Enclosure
F = NEMA Type 1 indoor with
combination trim
S = NEMA Type 1 indoor with
surface trim
R1 = NEMA Type 3R rainproof

1
1
1
1

Example No. 1: BR1224L125G

Example No. 2: BR24L70RP

Example No. 3: 3B4242EFN

Single-phase Type BR
loadcenter rated at 125A with
main lugs, 12 spaces allowing
24 poles, indoor combination
enclosure, aluminum bus and
ground bar.

Single-phase Type BR
loadcenter rated at 70A
with main lugs, two spaces
allowing four poles, rainproof
enclosure with aluminum bus.

Three-phase Type BR
loadcenter rated at 600A
with main breaker, 42 spaces
allowing 42 poles, indoor
combination enclosure.

1
1
1
1

Note
1 No character space used.

1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-45

1.2

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

1

Product Selection

1

Single-Phase—Main Circuit Breaker Loadcenters—10/25 kAIC

1

BR4040B200

Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Split Neutral

1

Main
Breaker Type

Main
Ampere Rating

Maximum Number
1-Inch (25.4 mm)
Spaces
Circuits

Enclosure
Type

Box
Size

Wire Size Range
Cu/Al 60°C or 75°C
for Main Breaker

Loadcenter Catalog Number
with Combination 1 or
NEMA Type 3R Cover

1

BR
10 kAIC

100

8

16

Indoor

B1

#4–1/0 2

BR816B100

10

20

Indoor

A1

BR1020B100S11

1

10

20

Indoor

A1

BR1020B100F11

10

20

Outdoor

B2R

BR1020B100RF 34

1

12

12

Indoor

B2

BR1212B100

12

20

Indoor

B2

BR1220B100

1

12

24

Outdoor

B2R

BR1224B100R 4

16

16

Indoor

C1

BR1616B100

1

16

20

Indoor

C1

BR1620B100

16

24

Outdoor

C1R

BR1624B100R 4

20

24

Outdoor

C3R

BR2024B100R 4

20

20

Indoor

C2

BR2020B100

16

24

Indoor

C1

BR1624B100

30

30

Indoor

D1

16

24

Indoor

C1

20

24

Indoor

C1

20

24

Outdoor

C3R

BR2024B125R 4

30

30

Indoor

D1

BR3030B125

20

24

Indoor

C2

#4–1/0

BR2024H100 6

#2–300 kcmil

BR816B150RF 34

1
1

125

1
1
1

BRH 6
22 kAIC

100

CSR 7
25 kAIC

150

BR3030B100
#4–2/0

BR1624B125
BR2024B125

8

16

Outdoor

C3R

16

30

Indoor

C4

BR1630B150

20

30

Indoor

C4

BR2030B150

1

20

30

Outdoor

D1R

BR2030B150R 4

20

40

Indoor

D1

BR2040B150

1

20

40

Outdoor

D1R

BR2040B150R 4

24

30

Indoor

G1

BR2430B150

30

30

Outdoor

G1R

BR3030B150R 4

30

30

Indoor

G1

BR3030B150

30

40

Indoor

G1

4

8

Outdoor

8R

1

8

16

Outdoor

C3R

BR816B200RF 34

16

32

Indoor

C4

BR1632B200

1

20

40

Outdoor

D1R

BR2040B200R 4

20

40

Indoor

D1

BR2040B200

1

24

40

Indoor

G1

BR2440B200

30

40

Outdoor

G1R

BR3040B200R 4

30

40

Indoor

G1

BR3040B200 j

40

40

Outdoor

L1R

BR4040B200R 4

40

40

Indoor

L1

BR4040B200

40

50

Indoor

L1

42

42

Indoor

L2

42

42

Outdoor

L2R

1

1
1

200

1
1

225

1

BR3040B150
#2–300 kcmil

BR48B200RF 389

BR4050B200
#1–250 kcmil

BR4242B225
BR4242B225R 4

Notes
1 Combination style covers may be used in surface or flush applications.
2 Wire range size for BR1020B100SP is #6–#1 Cu/Al.
3 Includes through-feed lugs for both phase and neutral conductors.
4 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-65.
5 See copper bus offering, Page V1-T1-53.
6 22 kAIC series combination rating is obtained when Types BD, BR, BQ, BQC and GFCB 10 kAIC branch breakers are used in series with Type BRH main breaker.
7 25 kAIC series combination rating is obtained when Types BD, BR, BQ, BQC and GFCB 10 kAIC branch circuit breakers are used in series with Type CSR main breaker.
8 Supplied with adapter plate to use DS Group1 hubs on Page V1-T1-65. If 2.50-inch (63.5 mm) hub is needed, remove adapter and use ARP00007CH25 hub.
9 Neutral is bonded—suitable for service entrance only—cannot be converted for sub-feed application.
j Add G to the end of the catalog number for factory-installed GBK2120 ground bar.
All main circuit breaker loadcenters are listed for use as service entrance equipment and are shipped with neutral bonding strap preattached. The maximum rating of the
panel is the main circuit breaker rating when used as service entrance equipment. Ground bar kits priced separately. See Page V1-T1-65.

1
1
1
1
1
V1-T1-46

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

1.2

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Main Circuit Breaker Loadcenters—10/22 kAIC
B4242DFN

1

Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Split Neutral
Main
Breaker
Type

Main
Ampere
Rating

DK 4

HLD

6

Maximum Number
1-Inch (25.4 mm)
Spaces

Circuits

Enclosure
Type

Box
Size

Wire Size Range
Cu/Al 60°C or 75°C
for Main Breaker

300

42

42

Indoor

24

400

42

42

Indoor

24

42

42

Outdoor

42

42

Indoor

600

1

Commercial Loadcenter
Catalog Number 123
With Flush or
NEMA Type 3R Cover

With
Surface Cover

(2) #3/0–250 kcmil

BR304242F

BR304242S

(2) #3/0–250 kcmil

B4242DFN

B4242DSN

47

(2) #3/0–250 kcmil

B4242DR1N 5

—

24

(2) #3/0–500 kcmil

B4242EFN

B4242ESN

1
1
1
1

Notes
1 Ground bar kits priced separately. See Page V1-T1-65.
2 The maximum rating of the panel is the main circuit breaker rating when used as service entrance equipment.
3 Door lock and key included with loadcenter.
4 Type DK main circuit breaker is rated 65 kAIC at 240 Vac and allows a 22 kAIC series rating on the panel when Types BR, BD and BJ branch circuit breakers are used.
5 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-65.
6 Type HLD main circuit breaker is rated 65 kAIC at 240 Vac. Type HLD circuit breaker is not series rated with Types BR, BD and BJ branch circuit breakers.
Box sizes Pages V1-T1-66 through V1-T1-69.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-47

1.2
1

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Single-Phase—Main Lug Loadcenters

1

Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Split Neutral

1

Main
Ampere Rating

1

Spaces

Circuits

Enclosure
Type

Trim Type

Box
Size

Wire Size Range
Cu/Al 60°C or 75°C
for Main Lugs

Loadcenter
Catalog Number
BR24L70SP 12

2

4

Indoor

Surface (no door)

5

2

4

Indoor

Surface (no door)

5

BR24L70SGP 23

2

4

Outdoor

—

5R

BR24L70RP 124

2

4

Indoor

Flush (no door)

5

BR24L70FP 12

2

4

Indoor

Flush (no door)

5

2

4

Indoor

Surface (no door)

6

2

4

Outdoor

—

6R

BR24L125RP 124

2

4

Outdoor

—

6R

BR24L125RSEP 278

2

4

Outdoor

—

6R

BR24L125RSE2P 267

1

2

4

Indoor

Flush (no door)

6

BR24L125FP 12

4

8

Indoor

Surface (no door)

7

1

4

8

Indoor

Surface (no door)

7

BR48L125SGP 39

4

8

Outdoor

—

7R

BR48L125RP 149

1

4

8

Indoor

Flush (no door)

7

BR48L125FP 19

4

8

Indoor

Flush (with door)

7

BR48L125FDP 19

1

4

8

Indoor

Flush (no door)

7

6

12

Indoor

Surface (no door)

7

1

6

12

Indoor

Surface (no door)

7

BR612L125SGP jk

6

12

Indoor

Surface (with door)

7

BR612L125SDP 1j

6

12

Indoor

Surface (with door)

7

BR612L125SDGP jk

6

12

Outdoor

—

7R

BR612L125RP 14j

6

12

Indoor

Flush (no door)

7

BR612L125FP 1j

6

12

Indoor

Flush (no door)

7

BR612L125FGP 5jk

6

12

Indoor

Flush (with door)

7

BR612L125FDP j

6

12

Indoor

Flush (with door)

7

BR612L125FDGP 5jk

8

16

Indoor

Surface (no door)

7

8

16

Indoor

Surface (no door)

7

BR816L125SGP jl

8

16

Indoor

Surface (with door)

7

BR816L125SDP 1j

1

8

16

Indoor

Surface (with door)

7

BR816L125SDGP jl

1

8

16

Outdoor

—

7R

BR816L125RP 14j

8

16

Indoor

Flush (no door)

7

BR816L125FP 1j

8

16

Indoor

Flush (no door)

7

BR816L125FGP 5jl

8

16

Indoor

Flush (with door)

7

BR816L125FDP 1j

8

16

Indoor

Flush (with door)

7

BR816L125FDGP 5jl

Surface

Outdoor

70

Maximum Number
1-Inch (25.4 mm)

1
1
1

125
Flush

Outdoor

1

1

Surface (No Door)

Flush (No Door)

1
1
1

Outdoor

1

1
1

#8–#2

BR24L70FGP 25
#14–1/0

#14–1/0

BR24L125SP 12

BR48L125SP 19

BR48L125FGP 39
#14–#1

#14–#1

BR612L125SP 1j

BR816L125SP 1j

Notes
1 Ground bar kits priced separately. See Page V1-T1-65.
– For 2/4 circuit loadcenters, use GBK5 or GBK520 ground bar.
– For 4/8, 6/12 and 8/16 circuit loadcenters, use GBK10 ground bar.
– Ground bars mount to the left side wall of the enclosure for the 4/8, 6/12 and 8/16 circuit loadcenters.
2 Suitable for use as service equipment when not more than two service disconnecting mains are provided or when not used as a lighting and appliance panelboard
(see Article 408.34 of the NEC).
3 Ground bar GBK5 is installed.
4 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-65.
5 CSA and UL approved.
6 Neutral/ground holes (6) #14–6 and (3) #14–2/0 AWG Cu/Al.
7 For use as service entrance applications only.
8 Neutral/ground holes (6) #14–6 and (3) #14–1/0 AWG Cu/Al.
9 Suitable for use as service equipment when not more than two service disconnecting mains are provided or when not more than six service disconnecting mains are provided and
when not used as a lighting and appliance panelboard (see Article 408.34 of the NEC).
j Suitable for use as service equipment when a main breaker is used or when not more than six service disconnecting mains are provided and when not used
as a lighting and appliance panelboard (see Article 408.34 of the NEC).
k Ground bar GBK10 is installed.
l Ground bar GBK14 is installed.

1
1
1
1
1
1
1
1

Box sizes Pages V1-T1-66 through V1-T1-69.

V1-T1-48

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

1.2

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Single-Phase—Main Lug Loadcenters

1
1

Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Split Neutral, continued
Main
Ampere Rating
BR1224L125

125

150

BR1224L200

200

225

Maximum Number
1-Inch (25.4 mm)
Spaces

Circuits

Enclosure
Type

Box
Size

Wire Size Range
Cu/Al 60°C or 75°C
for Main Lugs

12

12

Indoor

B1

#6–2/0

Loadcenter Catalog Number
with Combination or
NEMA Type 3R Cover 1
BR1212L125 2345

24

Indoor

B1

BR1224L125

12

24

Indoor

B1

BR1224L125G 245

12

24

Indoor

B1

BR1224L125DG 2456

12

24

Outdoor

B1R

BR1224L125R 257

16

16

Indoor

B2

BR1616L125 245

16

24

Indoor

B2

BR1624L125 24

16

24

Indoor

B2

BR1624L125G 24

24

Outdoor

B2R

BR1624L125R

20

20

Indoor

C1

BR2020L125 245

20

24

Indoor

C1

BR2024L125 24

20

24

Indoor

C1

BR2024L125G 248

20

24

Outdoor

C1R

BR2024L125R 27

24

24

Indoor

C2

BR2424L125 24

24

24

Indoor

C2

BR2424L125G 248
BR3042L125

1
1
1
1
1
1
1

24

30

42

Indoor

D1

16

30

Indoor

C2

20

30

Indoor

C2

8

16

Outdoor

B2R

12

24

Indoor

B2

BR1224L200 459

12

24

Outdoor

B2R

BR1224L200R 579

20

40

Indoor

C2

BR2040L200 49

20

40

Indoor

C2

BR2040L200G 489

20

40

Outdoor

C3R

BR2040L200R 79

24

40

Indoor

C4

BR2440L200 49

30

40

Indoor

D1

BR3040L200 49

30

40

Indoor

D1

BR3040L200G 489

30

40

Outdoor

D1R

BR3040L200R 79

40

40

Indoor

G1

BR4040L200 49

40

40

Indoor

G1

BR4040L200G 49

40

40

Outdoor

G1R

BR4040L200R 79

42

42

Indoor

L1

42

42

Outdoor

L1R

#1–300 kcmil

1

27

16

BR1630L150 49

1

BR2030L150 49
#1–300 kcmil

#1–300 kcmil

1
1

245

12

1

BR816L200RF 57j

1
1
1
1
1
1
1
1

BR4242L225 4
BR4242L225R 7

Notes
1 Ground bar kits priced separately unless otherwise noted. See Page V1-T1-65.
2 Has notch for BREQS125 hold-down kit.
3 Single, movable neutral is provided.
4 Combination cover style.
5 Suitable for use as service equipment when not more than six main disconnecting means are provided and when not used as a lighting and appliance panelboard
(see Article 408.34 of the NEC).
6 Ground bars GBK5 and GBK520 installed.
7 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-65.
8 Ground bar GBK1220 installed.
9 Has notch for BRHDK125 hold-down kit.
j Includes through-feed lugs for both phase and neutral conductors.

1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-49

1.2

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

1

Single-Phase—Main Lug Loadcenters—400 and 600A

1

4242DFN

Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Split Neutral
Maximum Number
1-Inch (25.4 mm)

1
1

Main
Ampere Rating

Spaces

Circuits

Enclosure
Type

Box
Size

400

12

24

Indoor

19

1
1
1

600

1

Wire Size Range
Cu/Al 60°C or 75°C
for Main Lugs
(1) #4/0–750 kcmil
or
(2) #3/0–400 kcmil

Commercial Loadcenter
Catalog Number 123
With Flush or NEMA
Type 3R Cover

With Surface
Cover

—

1224DSN 5

12

24

Outdoor

42

24

42

Indoor

20

—

42

42

Indoor

22

4242DFN

4242DSN

42

42

Outdoor

46

4242DR1N 4

—

42

42

Indoor

22

—

4242ESN

(2) #2–500 kcmil

1224DR1N

45

—
2442DSN

Notes
1 Ground bar kits priced separately unless otherwise noted. See Page V1-T1-65.
2 Has notch for BRHDK125 hold-down kit.
3 Ground bar GBK8 installed.
4 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-65.
5 Suitable for use as service equipment when not more than six main disconnecting means are provided and when not used as a lighting and appliance panelboard
(see Article 408.34 of the NEC).

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
V1-T1-50

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

1.2

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Convertible Loadcenters MCB or MLO—Base Units and Main Devices 10/22/25 kAIC,
Complete Assembly Consists of: Loadcenter and Either Main Breaker Kit or Main Lug Kit

1

Note: Interrupting rating depends on main circuit breaker selected.

1

BR3040N200

1

Base Units—Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Split Neutral
(Unless Otherwise Noted)
Main
Ampere Rating 1
125 4

200 8

Maximum Number
1-Inch (25.4 mm)
Spaces

Circuits

Enclosure
Type

12

24

Indoor

Box
Size
B2

Wire Size Range
Cu/Al 60°C or 75°C
for Main

Loadcenter Catalog Number
With Combination or NEMA
Type 3R Cover 23

See main breaker and
main lug kit tables
Page V1-T1-54.

BR1224N125 56

24

Outdoor

B2R

16

24

Indoor

C1

BR1624N125 5

16

24

Outdoor

C1R

BR1624N125R 57

1
1

5

20

24

Indoor

C2

BR2024N125

20

24

Outdoor

C3R

BR2024N125R 57

8

16

Outdoor

C3R

BR816N200RF 79jk

12

24

Indoor

C4

BR1224N200 j

12

24

Outdoor

C3R

BR1224N200R 7j

16

32

Indoor

C4

BR1632N200 j

20

40

Indoor

D1

BR2040N200 j

20

40

Indoor

D1

BR2040N200G l

20

40

Outdoor

D1R

BR2040N200R 7j

20

40

Outdoor

D1R

BR2040N200RG l

24

40

Indoor

G1

BR2440N200 7j

30

40

Indoor

G1

BR3040N200 j

30

40

Indoor

G1

BR3040N200G l

30

40

Outdoor

G1R

BR3040N200R 7j

30

40

Outdoor

G1R

BR3040N200RG l

40

40

Indoor

L1

BR4040N200 j

40

40

Indoor

L1

BR4040N200G l

40

40

Outdoor

L1R

BR4040N200R 7j

40

40

Outdoor

L1R

BR4040N200RG l

1
1

BR1224N125R 567

12

1

1
1
1
1
1
1
1
1
1
1

Notes
1 The maximum rating of the loadcenter is the main circuit breaker rating when used as service entrance equipment.
2 100, 125 and 200A convertible base unit catalog numbers include interior, box and cover only. Main devices and accessories must be ordered separately for field
installation. All convertible base units are listed as suitable for use as service entrance equipment when used per Article 384 of the NEC.
3 Ground bar kits priced separately except as noted, refer to Page V1-T1-65.
4 For main breaker, use Type BR. For main lug use Type BRSF.
5 BREQS125 hold-down screw comes with loadcenter for back-fed Types BR and BRH main circuit breakers.
6 Convertible to maximum of 100A main circuit breaker and 125A main lug.
7 Rainproof loadcenters are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-65.
8 For main breaker, use Type BW or CSR. For main lug, use Type BRL.
9 Includes through-feed lugs for both phase and neutral conductors.
j No hold-down provisions for back-fed Types BR and BRH main circuit breakers.
k Insulated/bondable single neutral.
l Includes GBK2120 ground bar.

1
1
1
1
1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-51

1.2

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

1

Convertible Loadcenters MCB or MLO—Base Units and Main Devices 10/22/25 kAIC,
Complete Assembly Consists of: Loadcenter and Either Main Breaker Kit or Main Lug Kit

1

Note: Interrupting rating depends on main circuit breaker selected.

1

BW2200

1

Main Devices—Two- and Three-Pole
Main Circuit Breakers—120/240 Vac or
208Y/120 Vac or 240 Vac
Ampere
Rating

1

Wire Size Range
Cu/Al 60°C or 75°C
for Main Breaker

10 kAIC

22/25 kAIC

Catalog
Number

Catalog
Number 1

Main Devices—Two- and Three-Pole
Main Lug Kits—120/240 Vac or
208Y/120 Vac or 240 Vac

BRL200

Ampere
Rating

Catalog
Number

Two-Pole

Two-Pole

1

Wire Size Range
Cu/Al 60°C or 75°C
for Main Lugs

100

#4–1/0

BR2100

BRH2100

125

#6–2/0

BRSF125

1

110

#4–1/0

BR2110

BRH2110

150

#1–300 kcmil

BRL200

125

#4–2/0

BR2125

BRH2125

175

#1–300 kcmil

BRL200

1

125

#2–300 kcmil

BW2125

CSR2125N

200

#1–300 kcmil

BRL200

#6–3/0

3BRSF150

150

#2–300 kcmil

BW2150

CSR2150N

Three-Pole

1

175

#2–300 kcmil

BW2175

CSR2175N

150

1

200

#2–300 kcmil

BW2200

CSR2200N

Three-Pole
BR3100

BRH3100

100

1
1
1
1

#1

Main Circuit Breaker with Accessory
Example: BW22005R01 (Put description with catalog number on
order. See Page V1-T1-86.)

Main Circuit Breaker Loadcenters—Copper Bus 10/22/25 kAIC
BR3030BC100

Main Circuit Breaker Loadcenters—With Copper Bus—Single-Phase Three-Wire—120/240 Vac—
Insulated/Bondable Split Neutral

1

Main
Breaker Type

Main
Ampere Rating

1

BR
10 kAIC

100

1

BRH
22 kAIC 4

1

CSR
25 kAIC

1

Maximum Number
1-Inch (25.4 mm)

20

20

Indoor

C2

#4–1/0

BR2020BC100

30

30

Indoor

D1

#4–1/0

BR3030BC100

100

30

30

Indoor

D1

#4–1/0

BR3030HC100

150

30

30

Indoor

G1

#2–300 kcmil

BR3030BC150

200

20

40

Indoor

D1

#2–300 kcmil

BR2040BC200

30

40

Indoor

G1

#2–300 kcmil

BR3040BC200

40

40

Indoor

L1

#2–300 kcmil

BR4040BC200

Main Lug Only Loadcenters—Copper Bus

1

BR816LC125FDP

Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Single Neutral with Copper Bus
Main
Ampere Rating
125

1
1

Loadcenter Catalog Number
with Combination Cover 23

Circuits

1

1

Wire Size Range
Cu/Al 60°C or 75°C
for Main Breaker

Spaces

1

1

Box
Size

Enclosure
Type

Maximum Number
1-Inch (25.4 mm)

Trim Type

Box
Size

Wire Size Range
Cu/Al 60°C or 75°C
for Main Lugs

Loadcenter
Catalog Number

#14–1

BR816LC125SDP

Spaces

Circuits

Enclosure
Type

8

16

Indoor

Surface (with door)

7

8

16

Indoor

Flush (with door)

7

BR816LC125FDP

Notes
1 Series combination rating with Types BD, BR, BQ, BQC and GFCB is 22 kAIC with BRH main and 25 kAIC with CSR main.
2 All main circuit breaker loadcenters are listed for use as service entrance equipment and are shipped with neutral bonding strap preattached. The maximum rating of the
panel is the main circuit breaker rating when used as service entrance equipment.
3 Ground bar kits priced separately. See Page V1-T1-65.
4 22 kAIC series combination rating is obtained when Types BD, BR, BQ, BQC and GFCB 10 kAIC branch breakers are used in series with Type BRH main breaker.

1
1
1

Box sizes Pages V1-T1-66 through V1-T1-69.

1
V1-T1-52

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

1.2

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Convertible Loadcenters—Copper Bus 10/22/25 kAIC
BR3040NC200

1

Convertible—Single-Phase, Three-Wire—120/240 Vac—Insulated/Bondable Split Neutral
Main
Ampere Rating
125
10/22 kAIC 45

200
10/25 kAIC 49

Maximum Number
1-Inch (25.4 mm)
Spaces

Circuits

Enclosure
Type

Box
Size

12

24

Indoor

B2

12

24

Outdoor

B2R

Wire Size Range
Cu/Al 60°C or 75°C
for Main

Loadcenter Catalog Number
(With Combination or
NEMA Type 3R Cover) 123

See main breaker
and main lug kit tables
on Page V1-T1-54.

BR1224NC125 67

1

7

24

Indoor

C2

BR2024NC125

20

24

Outdoor

C3R

BR2024NC125R 78

20

40

Indoor

D1

BR2040NC200

20

40

Outdoor

D1R

BR2040NC200R 8

30

40

Indoor

G1

BR3040NC200

30

40

Outdoor

G1R

BR3040NC200R 8

40

40

Indoor

L1

BR4040NC200

40

40

Outdoor

L1R

BR4040NC200R 8

1
1

BR1224NC125R 678

20

1

1
1
1

Notes
1 100, 125 and 200A convertible base unit catalog numbers include interior, box and cover only. Main devices and accessories must be ordered separately for field
installation. All convertible base units are listed as suitable for use as service entrance equipment when used per Article 384 of the NEC.
2 Ground bar kits priced separately, refer to Page V1-T1-65.
3 All main circuit breaker loadcenters are listed for use as service entrance equipment and are shipped with a neutral bonding strap preattached. The maximum main
rating of the loadcenter is the main breaker rating when used as service entrance equipment.
4 Interrupting rating depends on main circuit breaker selected. See Page V1-T1-65 for mains.
5 For main breaker, use Type BW or CSR. For main lug, use Type BRL.
6 Rainproof loadcenters are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-65.
7 Hold-down screw BREQS125 comes with loadcenter for back-fed Types BR and BRH main circuit breakers.
8 For main breaker, use Type BR. For main lug, use Type BRSF.
9 Suitable for use as service equipment when not more than six main disconnecting means are provided and when not used as a lighting and appliance panelboard.
(see Article 408.34 of the NEC).

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-53

1.2
1

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Three-Phase—Type BR Main Circuit Breaker Loadcenters
Three-Phase, Four-Wire—Main Lug Loadcenters—Copper Bus—208Y/120 Vac or 240 Vac,
Insulated/Bondable Split Neutral

1
1

Main
Ampere Rating

Maximum Number
1-Inch (25.4 mm)

Enclosure
Type

Box
Size

Wire Size Range
Cu/Al 60°C or 75°C
for Main

Loadcenter Catalog Number
(With Combination or
NEMA Type 3R Cover)

Spaces

Circuits

125

12

24

Indoor

C1

#6–3/0

3BR1224LC125

125

12

24

Outdoor

C1R

#6–3/0

3BR1224LC125R

150

24

42

Indoor

D1

#4–300 kcmil

3BR2442LC150

150

24

42

Outdoor

D1R

#4–300 kcmil

3BR2442LC150R

200

12

24

Indoor

C4

#4–300 kcmil

3BR1224LC200

200

12

24

Outdoor

C3R

#4–300 kcmil

3BR1224LC200R

200

30

42

Indoor

G1

#4–300 kcmil

3BR3042LC200

200

30

42

Outdoor

G1R

#4–300 kcmil

3BR3042LC200R

1

200

42

42

Indoor

L1

#4–300 kcmil

3BR4242LC200

200

42

42

Outdoor

L1R

#4–300 kcmil

3BR4242LC200R

1

225

30

42

Indoor

L1

#4–300 kcmil

3BR3042LC225

225

30

42

Outdoor

L1R

#4–300 kcmil

3BR3042LC225R

1
1
1
1

1

Three-Phase, Four-Wire—Main Circuit Breaker Loadcenters—Copper Bus—208Y/120 Vac or 240 Vac,
Insulated/Bondable Split Neutral

1
1
1
1

1
1

Wire Size Range
Cu/Al 60°C or 75°C
for Main Breaker

Loadcenter Catalog Number
(With Combination or
NEMA Type 3R Cover)

24

Indoor

C1

#14–1/0

3BR1224BC100

24

Outdoor

C1R

#14–1/0

3BR1224BC100R

30

42

Indoor

L1

#6–4/0

3BR3042BC150

150

30

42

Outdoor

L1R

#6–4/0

3BR3042BC150R

200

42

42

Indoor

L2

2/0–300 kcmil

3BR4242BC200

200

42

42

Outdoor

L2R

2/0–300 kcmil

3BR4242BC200R

225

42

42

Indoor

L2

2/0–300 kcmil

3BR4242BC225

225

42

42

Outdoor

L2R

2/0–300 kcmil

3BR4242BC225R

Spaces
12

100

12

CC
10 kAIC

150

Three-Phase, Four-Wire—Main Circuit Breaker Loadcenters—Aluminum Bus—208Y/120 Vac or 240 Vac
Insulated/Bondable Split Neutral

1
1

Wire Size Range
Cu/Al 60°C or 75°C
for Main Breaker

Loadcenter Catalog Number 12
(With Combination or
NEMA Type 3R Cover)

24

Indoor

C1

#14–1/0

3BR1224B100

24

Outdoor

C1R

30

42

Indoor

L1

#6–4/0

3BR3042B125

30

42

Indoor

L1

#6–4/0

3BR3042B150

30

42

Outdoor

L1R

30

42

Indoor

L1

30

42

Outdoor

L1R

Spaces
12
12

CC
10 kAIC

125
150

1

1

Box
Size

100

200

1

Circuits

Enclosure
Type

BR
10 kAIC

1
1

Maximum Number
1-Inch (25.4 mm)

Main
Ampere
Rating

Main
Breaker Type

1

Box
Size

100

1
3BR4242B200

Circuits

Enclosure
Type

BR
10 kAIC

1
1

Maximum Number
1-Inch (25.4 mm)

Main
Ampere
Rating

Main
Breaker Type

3BR1224B100R 3

3BR3042B150R 3
#1–250 kcmil

3BR3042B200
3BR3042B200R 3

42

42

Indoor

L2

3BR4242B200

42

42

Outdoor

L2R

3BR4242B200R 3

L2

2/0–300 kcmil

3BR4242H200 6

2/0–300 kcmil

3BR4242B225

CHH
100 kAIC

200

42

42

Indoor

CC
10 kAIC

225

42

42

Indoor

L2

42

42

Outdoor

L2R

DK 4
22 kAIC

400

42

42

Indoor

24

42

42

Outdoor

47

LD 5

600

42

42

Indoor

24

3BR4242B225R 3
(2) #3/0–250 kcmil

3B4242DFN
3B4242DR1N 3

(2) #3/0–500 kcmil

3B4242EFN

Notes
1 All main circuit breaker loadcenters are listed for use as service entrance equipment and are shipped with a neutral bonding strap pre-attached (commercial loadcenters
do not have a pre-attached bonding strip). The maximum main rating of the panel is the main circuit breaker rating when used as service entrance equipment.
2 Ground bar kits priced separately. See Page V1-T1-65.
3 Rainproof loadcenters are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-65.
4 Type DK main circuit breaker is rated 65 kAIC at 240 Vac and allows a 22 kAIC series rating on the loadcenter when Types BR, BD and BJ branch circuit breakers are used.
5 The LD main circuit breaker is rated 65 kAIC at 240 Vac. Type LD circuit breaker is not series rated with Types BR, BD and BJ branch circuit breakers.
6 Includes CHH 100 kAIC rated MCB. 100 kAIC series rating combination is obtained when types BD, BR, BQ, BQC and GFGB branch breakers are used with CHH main.

1
1
1
V1-T1-54

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

3BR1224L125

Three-Phase, Four-Wire—Main Lug Loadcenters—Aluminum Bus—208Y/120 Vac or 240 Vac,
Insulated/Bondable (Unless Otherwise Noted)
Main
Ampere Rating
100
125
150

200

225

34242DFN

1.2

Maximum Number
1-Inch (25.4 mm)

1

Box
Size

Wire Size Range
Cu/Al 60°C or 75°C
for Main Lugs

Loadcenter Catalog Number
(With Combination or
NEMA Type 3R Cover)

#6–1/0

3BR3L100S 23

Spaces

Circuits

Enclosure
Type

3

3

Indoor

9

3

3

Outdoor

9R

12

24

Indoor

C1

12

24

Outdoor

C1R

18

36

Indoor

C2

18

36

Outdoor

C3R

24

42

Indoor

D1

24

42

Outdoor

D1R

12

24

Indoor

C4

12

24

Outdoor

C3R

18

36

Indoor

C4

18

36

Outdoor

C3R

30

42

Indoor

G1

30

42

Outdoor

G1R

42

42

Indoor

L1

42

42

Outdoor

L1R

42

42

Indoor

L1

42

42

Outdoor

L1R

1

1

3BR3L100R 34
#6–3/0

1

3BR1224L125 56
3BR1224L125R 456

#6–4/0

1

3BR1836L150
3BR1836L150R

#4–300 kcmil

1

3BR2442L150
3BR2442L150R 4

#4–300 kcmil

1

3BR1224L200 6
3BR1224L200R 46

#4–300 kcmil

1

3BR1836L200
3BR1836L200R

#4–300 kcmil

1

3BR3042L200
3BR3042L200R 4

#4–300 kcmil

1

3BR4242L200
3BR4242L200R 4

#4–300 kcmil

1

3BR4242L225
3BR4242L225R 4

1

Three-Phase, Four-Wire—Main Lug Loadcenters—Aluminum Bus—208Y/120 Vac or 240 Vac,
Insulated/Bondable Split Neutral
Maximum Number
1-Inch (25.4 mm)
Main
Ampere Rating
400

600

Spaces

Circuits

Enclosure
Type

Box
Size

Wire Size Range
Cu/Al 60°C or 75°C
for Main Lugs

1

Commercial Loadcenter
Catalog Number g
With Flush or
NEMA Type 3R Cover

1

With
Surface Cover

42

42

Indoor

22

34242DSN

42

Outdoor

46

(1) 250–750 kcmil
or
(2) #3/0–250 kcmil

34242DFN

42

34242DR1N 4

—

42

42

Indoor

22

(2) #2–500 kcmil

—

34242ESN

Notes
1 Ground bar kits priced separately. See Page V1-T1-65.
2 Surface cover only.
3 Insulated/bondable single neutral.
4 Rainproof loadcenters are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-65.
5 Has notch for BREQS125 hold-down kit.
6 Suitable for use as service equipment when not more than six main disconnecting means are provided and when not used as a lighting and appliance panelboard
(see Article 408.34 of the NEC).
g Door lock and key included with loadcenter.

1
1
1
1
1
1
1
1

Box sizes Pages V1-T1-66 through V1-T1-69.

1
1
1
1
1
1
1
1
1
Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-55

1.2
1

3BR3030N100

1
1

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Three-Phase, Four-Wire—Convertible Loadcenters—Aluminum Bus—208Y/120 Vac or 240 Vac,
Insulated/Bondable Split Neutral

Spaces

100 4

30

3BR4242N225NY

1
1

Wire Size Range
Cu/Al 60°C or 75°C
for Main

Loadcenter Catalog Number 23
(With Combination or
NEMA Type 3R Cover)

See main breaker
and main lug kit tables
below.

3BR3030N100 5

Circuits

Enclosure
Type

Box
Size

30

Indoor

D1

30

30

Outdoor

D1R

3BR3030N100R 56

12

24

Indoor

C1

3BR1224N125 567

12

24

Outdoor

C1R

3BR1224N125R 5678

200

30

42

Indoor

L1

3BR3042N200

225

42

42

Indoor

L2

3BR4242N225

42

42

Indoor

B

3BR4242B225NY 9

1
1

Maximum Number
1-Inch (25.4 mm)

Main
Ampere Rating 1

125 4

1
1
1
1
1

Three-Phase Main Breaker Kits—10 kAIC

1

Ampere
Rating

Wire Size Range
Cu/Al 60°C or 75°C

Catalog
Number

1

100

#6–4/0

CC3100N

125

#6–4/0

1
1
1

Three-Phase Main Lugs Kit for
Convertible Loadcenters
Ampere
Rating

Wire Size Range
Cu/Al 60°C or 75°C

Catalog
Number

CC3125N

225

#1–300 kcmil

3BRL225

225

#1–300 kcmil

3BRS225 j

150

#6–4/0

CC3150N

175

#2/0–300 kcmil

CC3175N

200

#2/0–300 kcmil

CC3200N

225

#2/0–300 kcmil

CC3225N

Notes
1 The maximum rating of the loadcenter is the main circuit breaker
rating when used as service entrance equipment.
2 100, 125 and 200A convertible base unit catalog numbers include
interior, box and cover only. Main devices and accessories must be
ordered separately for field installation.
All convertible base units are listed as suitable for use as service
entrance equipment when used per Article 384 of the NEC.
3 Ground bar kits priced separately. See Page V1-T1-65.
4 For main breaker, use Type BR. For main lug, use Type BRSF.
5 BREQS125 hold-down screw comes with loadcenter for back-fed
Types BR and BRH main circuit breakers.
6 Rainproof loadcenters are furnished with hub closure plates. For
rainproof hubs, refer to Page V1-T1-65.
7 Convertible to maximum of 100A main circuit breaker and 125A
main lug.
8 Suitable for use as service equipment when not more than six
main disconnecting means are provided and when not used as a
lighting and appliance panelboard
(see Article 408.34 of the NEC).
9 Order 3BR42FTNY or 3BR42STNY cover separately.
j For subfeed.

1
1
1
1
1
1
1
1
1

Box sizes Pages V1-T1-66 through V1-T1-69.

1
1
1
1
V1-T1-56

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

1.2

Contents—BR Specialty Products

Spa Panels

Description

Page

Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BR Specialty Products
Spa Panels
Riser Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type BR Renovation Loadcenter . . . . . . . . . . .
Type BR Mechanical Interlock Kits . . . . . . . . . .
Type BR Retrofit Interior Kits . . . . . . . . . . . . . .
BR Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . .

V1-T1-42

1
1
1

V1-T1-58
V1-T1-59
V1-T1-61
V1-T1-72
V1-T1-75

1
1
1
1
1
1
1

BR Specialty Products

1

Spa Panels

1

Product Description

Features

Eaton’s BR Spa Panels
distribute power to outdoor
loads and provide protection
for people from electric
shock. Save time and money
with streamlined installation
procedures and easy-access
features. Spa panels meet
NEC requirements by
providing a ground fault
circuit interruption device and
a disconnect switch in a
single simple device. Ships
assembled prewired, factory
tested and ready to install.

●
●
●

1

10-year warranty
UL Listed
Factory-installed
two-pole ground fault
circuit interrupter (GFCI)

1
1
1
1

Product Selection
BR Spa Panel

1

Spa Panel—Meets NEC Article 680.40 Through 680.43—
Requirements for GFCI Protection
Main
Ampere
Rating

Maximum Number
1-Inch (25.4 mm)
Space

40
50

Poles

Enclosure
Type

Box
Size

Wire Size Range Cu/Al 60°C
or 75°C for Main Lugs

Catalog
Number

—

—

Outdoor

5R

#8–#2

BR40SPA 1

—

—

Outdoor

5R

#8–#2

BR50SPA 2

1
1
1
1

Notes
1 Includes a GFCB240 breaker, factory installed.
2 Includes a GFCB250 breaker, factory installed.

1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-57

1.2
1

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Contents—BR Specialty Products

Riser Panel

Description

1

Page

Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BR Specialty Products
Spa Panels. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Riser Panel
Type BR Renovation Loadcenter . . . . . . . . . . . .
Type BR Retrofit Interior Kits. . . . . . . . . . . . . . .
BR Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . .

1
1
1

V1-T1-42
V1-T1-57
V1-T1-59
V1-T1-72
V1-T1-75

1
1
1
1
1
1

Riser Panel

1

Product Description

1
1
1
1
1
1

Eaton’s Riser Panel is a
loadcenter with an offset
interior to allow riser cables
to pass through the enlarged
gutter. By using lay-in tap
lugs, the contractor is able to
simply strip off a length of the
riser cable’s insulation, and
tap off to the riser panel’s
main lugs. These panels are
used in the construction of
assisted living homes,
dormitories, public housing
complexes and apartments.

1

Product Selection
BR1224L125RIS

Main Ampere
Rating

BRGUTTER (Shown
with Loadcenter)

1

Riser Panel
Maximum Number
1-Inch (25.4 mm)
Space

Circuits

Enclosure
Type

Box
Size

12

24

Indoor

C4

#6–2/0

BR1224L125RIS

125

12

24

Indoor

C4

#6–2/0

BR1224L125RISBP 1

125

20

24

Indoor

C4

#6–2/0

BR2024L125RIS

125

20

24

Indoor

C4

#6–2/0

BR2024L125RISBP 1

125

20

30

Indoor

C2

#6–2/0

BR2030L125RIS

200

30

40

Indoor

D1

#1–300

BR3040L200RIS

Riser Panel Accessories
Catalog Number

GTAP250

1
1

Notes
1 Bulk-packaged loadcenter without carton. Must be ordered in
multiples of 16.
2 Refer to Page V1-T1-67 for dimensions. BRGUTTER is box
size C2.

1
1
1

Accessories

1

For riser panels not shown, contact the Flex Center at
1-800-330-6479 for both CH and BR riser panels.

1
1
1
V1-T1-58

Catalog
Number

125

BRGUTTER 2

1

Wire Size Range
Cu/Al 60°C or 75°C
for Main Lugs

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

1.2

Contents—BR Specialty Products

BR Renovation Loadcenters

Description

Page

Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BR Specialty Products
Spa Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Riser Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type BR Renovation Loadcenter
Options and Accessories . . . . . . . . . . . . . .
Type BR Retrofit Interior Kits . . . . . . . . . . . . . .
BR Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . .

V1-T1-42
V1-T1-57
V1-T1-58
V1-T1-60
V1-T1-72
V1-T1-75

1
1
1
1
1
1
1
1
1
1
1

Type BR Renovation Loadcenter
Product Description
●

●

●

●

●

Available in 10, 20, 30
and 40 circuit main
breaker styles
Designed to replace
existing loadcenters
and fuse boxes
Type BR loadcenter
packaged with circuit
breakers
Factory-installed 5-circuit
terminal block(s)
Twin-stacked neutral
design

Features, Benefits and Functions
Quick-Pro
All you need to
know to save
time and make
more money.
Specified on certain Eaton
products, the Quick-Pro
symbol allows for immediate
recognition of products
that are designed for
straightforward installation.
When you see Quick-Pro,
you know you can install
quickly—sometimes up to
50% less than the usual
installation time—and move
on to your next job.
SM

●

●

Factory-installed terminal
block(s) allows installer to
terminate existing short
wires without using wire
nuts or junction boxes
Twin-stacked neutrals are
mounted up high in the
loadcenter, which allows
for all neutral and ground
wires to be terminated in
the top half of the
loadcenter

●

●

●

Specifically designed for
the service contractor—
this is the ONLY renovation
line in the industry
Single-pole and two-pole
breakers included
10-year warranty on
loadcenter and breakers

1
1
1
1
1
1
1
1
1

Product Selection
BR2020B100RN

1

1

BR Value Packs 1
Main
Breaker
Type

Description

BR
10 kAIC

Single-phase 100A 10k main breaker 10/20
circuit surface-mount box is 11.75" wide x 13" tall

CSR
25 kAIC

1

Wire Size
Range

Number of
5-Circuit
Terminal Blocks

Single-Pole
Breakers

Two-Pole
Breakers

Catalog
Number

#6–1/0

0

(2) BR115

(1) BR230

BR1020B100SRNV

1

Single-phase 100A 10k main breaker 10/20
circuit flush-mount box is 11.75" wide x 13" tall

0

(2) BR115

(1) BR230

BR1020B100FRNV

1

Single-phase 100A
10 kAIC main breaker 20/20 circuit

1

(5) BR120

(1) BR230

BR2020B100RNV8

1

2

(5) BR115
(5) BR120

(1) BR230
(1) BR250

BR3040B100RNV4

1

Single-phase 200A
25 kAIC main breaker 30/40 circuit

#2–300
kcmil

1

Note
1 Indoor enclosure type.

1
1
Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-59

1.2
1
1

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Options and Accessories

BRSF125

Field Installation Kits and Parts

1

Number
of Poles

1

Main and Sub-Feed Lug Blocks

1

2
3BRS225

1

3

1
1

Wire Size Range
Cu/Al 60°C or 75°C

Ordering
Quantity 1

Catalog
Number

125

2

#8–2/0

1

BRSF125

150

2

#8–2/0

1

BRSF150 2

225

4

#2–300 kcmil

1

BRS225

150

3

#8–2/0

1

3BRSF150 2

225

6

#2–300 kcmil

1

3BRS225

Main Lugs
BRL200

1
1
1

Number of 1-Inch (25.4 mm)
Spaces Needed

Ampere
Rating

Two-pole, 200A stud mounted (includes deadfront filler plate)

#1–300 kcmil

1

BRL200

Neutral/ground lug
Add-on neutral or ground lug

#2/0 maximum

1

NL20

#3/0 maximum

1

NL30

300 kcmil maximum

1

NL300

Filler Plates

TDL

1-inch (25.4 mm) circuit breaker space

25

BRFP

BW main circuit breaker space (with hardware)

1

BWFP

1

Door lock —12–42 circuits, and 100–225A

1

TDL

1

Door lock—4–8 circuits, 125A

1

CH9FL

ANSI-61 light gray touchup paint for current loadcenters

1

SPC61

Isolated neutral assembly (computer circuits)

1

BINA

Circuit directory—adhesive backed

10

TCD

1
1
1
1
1

Cover screws

25

LCCS

Cover replacement latch (gray) 14-5/16 (363.5 mm) wide loadcenters only

1

BRRL

Circuit marking strip (next to breaker)

10

BRMS

Circuit identification label (preprinted breaker labels)

25

CHBL

Series rated caution label

25

SRL

Bonding strip with screw

1

BSSUSE

Notes
1 Must be purchased in multiples of ordering quantities indicated.
2 #8–2/0 wire size range is 75°C rated only.

1
1
1
1
1
1
1
1
1
1
1
1
V1-T1-60

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

1.2

Contents

Type BR Mechanical Interlock Kits

Description
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BR Specialty Products
Spa Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Riser Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type BR Renovation Loadcenter . . . . . . . . . . .
Type BR Retrofit Interior Kits . . . . . . . . . . . . . .
Type BR Mechanical Interlock Kits
BR Circuit Breakers
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
Circuit Breaker Accessories . . . . . . . . . . . . . . .
Wiring Diagrams. . . . . . . . . . . . . . . . . . . . . . . .

Page
V1-T1-42
V1-T1-57
V1-T1-58
V1-T1-59
V1-T1-72

V1-T1-76
V1-T1-84
V1-T1-86

1
1
1
1
1
1
1
1
1

Type BR Loadcenter with
Mechanical Interlock Kit

1
1

Type BR Mechanical Interlock Kits
Product Description

Features and Benefits

With the aging electrical
infrastructure and frequent
severe storms, power
outages are becoming more
and more frequent, affecting
thousands of people
nationwide. Eaton mechanical
interlock kit provides an easy
and cost-effective solution
when using backup
emergency power.

●

This solution expands the
robust line of emergency
power products and
accessories.

●

●
●

●

Prevents utility and
generator supplies from
being on at the same time
Protects utility linemen
from dangerous generator
backfeed
Robust interlock design
Offered in two unique
styles for almost any BR
loadcenter, which can
reduce inventory levels
Quick and easy
installation—drill points or
fixtures for pilot holes are
provided on all applicable
BR loadcenters; no
additional assembly is
required

1

Standards and Certifications
●

●

UL 67 Listed—For use with
BR loadcenters
Meets NEC® Article 702

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-61

1.2
1
1

Type BR Loadcenters and Circuit Breakers

Product Selection
Each mechanical interlock kit
includes:
●

1

●

1

●

●

Interlock assembly
Hold down kit 1
New labels
Necessary screws

1

Warranty information:
●

●

10-year warranty on all
Type BR circuit breakers
and loadcenters
Refer to Eaton for
complete warranty details

Mechanical Interlock Kits 2

1
1

Loadcenters and Circuit Breakers

Description
BRMIKBR

Catalog Number

Single

BRMIKBR

Bulk pack 3

BRMIKBRBP

Single

BRMIKCSR

Bulk pack 3

BRMIKCSRBP

1
1
1

BRMIKCSR

1
1
1
1
1

Notes
1 For breakers under 70A used in backfed applications, add “B” to the end of the catalog string
to get the appropriate “hold-down” version.
2 Clamshell packaged.
3 Bulk pack contains 10 units, individually packaged.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
V1-T1-62

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

1.2

Mechanical Interlock Cover
Covers mechanically interlock
two breakers—Type BW
or CSR main breaker with a
Type BR branch breaker.

BR816B100

1
1
1
1

Mechanical Interlock Cover
Fits Loadcenter
Catalog Numbers

Mechanical Interlock
Trim/Deadfront
Catalog Numbers

Mechanical Interlock Kit
Catalog Numbers

BRCOVC10M

BRMIKBR

1
1

Indoor
BR816B100

1

BR816N100
BR1212B100

1

BRCOVC12M

BR1220B100

1

BR1220H100
BR1224N125

BRCOVC13M

BR1616B100

BRCOVC16M

1
1

BR1620B100
BR1624B100
BR1624B125

BRCOVC17M

1

BRCOVC22M

1

BR1624N125
BR2020B100, BR2020BC100
BR2020H100, BR2020HC100

1

BR2024H100
BR2020HC100

1

BR2030B100

1

BR2040B100
BR2024B125

BRCOVC23M

1

BR2024N125, BR2024NC125
BR3030B100, BR3030BC100

BRCOVC59M

1

BR3030H100, BR3030HC100
Raintight
BR1020B100R

BR3RDF1M

BR1224B100R

1

Field-installed interlock kits not
available for these catalog numbers.

1

BR1224N125R, BR1224NC125R
BR1624B100R

BR3RDF2M

1

BR3RDF4M

1

BR1624N125R
BR2024B100R, BR2024B125R

1

BR2024N125R, BR2024NC125R

1
1
1
1
1
1
1
Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-63

1.2
1

BR4040B200

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Mechanical Interlock Cover, continued

1

Fits Loadcenter
Catalog Numbers

1

Indoor

1

BR1224N200

1

BR1632N200

BR1630B150

Mechanical Interlock
Trim/Deadfront
Catalog Numbers

Mechanical Interlock Kit
Catalog Numbers

BRCOV16C4FM

BRMIKCSR

BR1632B200

1

BR2030B150

1

BR2040B150

BRCOV20C4FM

BR2030H150

BR2040B200, BR2040BC200

1

BR2040H200

1

BR2430B150, BR2430BC150

BRCOV20D1FM

BR2040N200, BR2040NC200

1

BR3030B150

1

BR3040B150

BRCOV30G1FM

BR3030H150

BR2440B200

1

BR2440N200

1

BR3040N200, BR3040NC200

BR3040B200, BR3040BC200

1

BR3040H200

1

BR4040H200

BR4040B200, BR4040BC200

BRCOV40L1FM

BR4040N200, BR4040NC200

1

BR4242B225

1

Raintight

1

BR816B200RF

1

BR1224N200R

1

BR2040B150R

BR816B150RF

BRCOV42L2FM

BR3RDF5M 1

BR816N200RF

BR2030B150R

1

BR2040B200R

1

BR2040N200R

BR3RDF11M 1

BR2040B225R

BR3030B150R

1

BR3040B200R

1

BR4040B200R

BR3RDF12M 1

BR3040N200R
BR3RDF13M 1

1

BR4040N200R
BR48B200RF

BR3RDF14M

1

BR4242B225R

BR3RDF15M 1

Mechanical Interlock Loadcenter Replacement Covers 2

1

BR2020B100M, BR2020BC100M

1

BR2024H100M
BR3030BC100M

1

Notes
1 Deadfront only.
2 Can only be provided as replacement covers for factory-installed mechanically interlock loadcenters.

1
V1-T1-64

BRCOV20C2FM

Field-installed interlock kits not
available for these catalog numbers.

BRCOV30D1FM

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

DS300H2

1.2

Field Installation Rainproof Conduit Hubs
Conduit Size
Inches (mm)

Ordering
Quantity 1

Catalog
Number

0.75 (19.1)

1

DS075H1

1.00 (25.4)

1

DS100H1

1.25 (31.8)

1

DS125H1

1.50 (38.1)

1

DS150H1

2.00 (50.8)

1

DS200H1

Group 2—for use with 150, 200 and 225A MLO and MCB loadcenters and circuit breaker enclosures except for 2.00 (50.8)
the following 200A loadcenters: BR48B200RF. Also for use with 400 and 600A loadcenters and New York City
2.50 (63.5)
loadcenters manufactured after November 1, 2005
3.00 (76.2)

1

DS200H2

1

DS250H2

1

DS300H2

Description
Group 1—for use with 70, 100 and 125A MLO and MCB loadcenters and circuit breaker enclosures and the
following 150 and 200A panels: BR48B200RF

Type H conduit hubs for loadcenters PL0724R and S3100RN

Adapter kit—Allows Installing a Group 1 hub on devices arranged for Group 2 hubs

0.75 (19.1)

1

RH75P

1.00 (25.4)

1

RH100P

1.25 (31.8)

1

RH125P

1.50 (38.1)

1

RH150P

—

1

DS900AP

Group 1 small blank hub plate with bump

—

1

DS900CP1

Group 2 Large blank hub plate with bump

—

1

DS900CP2

1
1
1
1
1
1
1
1
1
1
1

GBK14

1

Ground Bar Kits
Ordering
Quantity 1

Catalog
Number

dssssds 2.54 (64.5)

1

GBK5 2

dssssdsj 3.59 (91.2)

Description
(See Legend)

Length
Inches (mm)

BRGBK39512

GBK520 2

1

GBK10 2

dssssdssssssj 5.34 (135.6)

1

GBK1020 2

4.61 (117.1)

1

GBK13 2

dssssdssssssssss 5.69 (144.5)

1

GBK14 2

dssssdssssssssssj 6.74 (171.2)

1

GBK1420 2

dssssdsssssssssssssssss 8.14 (206.8)

1

GBK21 2

dssssdsssssssssssssssssj 9.19 (233.4)

1

GBK2120 2

5.78 (146.8)

1

BRGBK39512 34

1

GB4NM 5

f
k
f
d
f
k
f
f
f
k
f
d
f
k
f
f
f
k
f

f
d
f
f
f
k
f
d
f
k
f
f
f

1

dssssdssssss 4.29 (109.0)

sssss 1.84 (46.7)

1
1
1
1
1
1
1
1

Ground Bar Legend

s (3) #14–10 Cu/Al or (1) #14–4 Cu/Al
j (1) #6–2/0 Cu/Al
(1) #14–1/0 Cu/Al or (3) #14–10 Cu/Al
(1) #14–6 Cu/Al or (2) #14–12 Cu/Al
d Mounting Hole

fk

1
1
1

Notes
1 Must be purchased in multiples of ordering quantities indicated.
2 Distance between mounting holes is 1.75 inches (44.5 mm).
3 For single- and three-phase 400 and 600A applications.
4 Distance between mounting holes is 2.34 inches (59.5 mm).
5 For non-metallic enclosures. Snaps into molded base.

1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-65

1.2
1
1

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Dimensions
Approximate Dimensions in Inches (mm)
Residential/Commercial/New York City Loadcenters, Unit Enclosures—Box Sizes

1

Note: Box sizes do not include covers/fronts.

1

Residential Loadcenters—NEMA Type 1 Indoor

Commercial Loadcenters—NEMA Type 1 Indoor

Box Size

Height

Width

Depth

Box Size

Height

Width

Depth

1

A1

15.00 (381.0)

11.25 (285.8)

3.75 (95.3)

19

44.00 (1117.6)

16.16 (410.4)

6.25 (158.8)

1

B1

16.75 (425.5)

14.31 (363.5)

3.88 (98.4)

20

44.00 (1117.6)

16.16 (410.4)

6.25 (158.8)

B2

18.75 (476.3)

14.31 (363.5)

3.88 (98.4)

22

54.00 (1371.6)

16.22 (412.0)

6.31 (160.3)

1

C1

21.00 (533.4)

14.31 (363.5)

3.88 (98.4)

24

66.50 (1689.1)

16.22 (412.0)

6.31 (160.3)

C2

23.00 (584.2)

14.31 (363.5)

3.88 (98.4)

1

C4

27.00 (685.8)

14.31 (363.5)

3.88 (98.4)

D1

29.13 (739.8)

14.31 (363.5)

3.88 (98.4)

1

G1

34.13 (866.8)

14.31 (363.5)

3.88 (98.4)

1

L1

39.00 (990.6)

14.31 (363.5)

3.88 (98.4)

L2

45.00 (1143.0)

14.31 (363.5)

3.88 (98.4)

1

2
3

9.44 (239.7)

4.50 (114.3)

3.00 (76.2)

1

4

13.00 (330.2)

11.00 (279.4)

3.56 (90.5)

5

9.44 (239.7)

4.50 (114.3)

3.00 (76.2)

6

12.00 (304.8)

6.88 (174.6)

4.50 (114.3)

7

13.00 (330.2)

11.00 (279.4)

3.56 (90.5)

9

14.50 (368.3)

6.50 (165.1)

3.50 (88.9)

1
1

8.63 (219.1)

5.00 (127.0)

3.50 (88.9)

1
1

Commercial Loadcenters—NEMA Type 3R Outdoor
Box Size

Height

Width

Depth

42

38.00 (965.2)

16.31 (414.3)

6.38 (161.9)

43

44.00 (1117.6)

16.31 (414.3)

6.38 (161.9)

46

54.00 (1371.6)

16.31 (414.3)

6.38 (161.9)

47

66.56 (1690.7)

16.31 (414.3)

6.38 (161.9)

New York City Loadcenters—NEMA Type 1 Indoor
Box Size

Height

Width

Depth

A

38.00 (965.2)

18.13 (460.4)

5.00 (127.0)

B

44.00 (1117.6)

18.13 (460.4)

5.00 (127.0)

C

66.50 (1689.1)

18.13 (460.4)

6.25 (158.8)

Residential Loadcenters—NEMA Type 3R Outdoor
Box Size

Height

Width

Depth

Types ECB and ECC Unit Enclosures—NEMA Type 1 Indoor

B1R

16.75 (425.5)

14.31 (363.5)

5.19 (131.8)

Height

Width

Depth

B2R

18.75 (476.3)

14.31 (363.5)

5.19 (131.8)

1

23.25 (590.6)

8.88 (225.4)

4.50 (114.3)

C3R

25.00 (635.0)

14.31 (363.5)

5.19 (131.8)

1

D1R

29.13 (739.8)

14.31 (363.5)

5.19 (131.8)

G1R

34.13 (866.8)

14.31 (363.5)

5.19 (131.8)

1

1

L1R

39.00 (990.6)

14.31 (363.5)

5.19 (131.8)

L2R

45.00 (1143.0)

14.31 (363.5)

5.19 (131.8)

1

2R

8.63 (219.1)

1

3R

9.44 (239.7)

4.50 (114.3)

3.00 (76.2)

4R

13.00 (330.2)

11.00 (279.4)

3.56 (90.5)

1

5R

9.44 (239.7)

4.50 (114.3)

3.00 (76.2)

6R

11.75 (298.5)

6.50 (165.1)

4.50 (114.3)

1

7R

13.00 (330.2)

11.00 (279.4)

3.56 (90.5)

8R

27.00 (685.8)

10.50 (266.7)

4.75 (120.7)

9R

14.25 (362.0)

6.50 (165.1)

4.00 (101.6)

C1R

21.00 (533.4)

14.31 (363.5)

5.19 (131.8)

1
1

5.00 (127.0)

3.50 (88.9)

Types ECB and ECC Unit Enclosures—NEMA Type 3R
Outdoor
Height

Width

Depth

23.68 (601.7)

9.31 (236.5)

5.44 (138.1)

1
1
1
1
V1-T1-66

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

1.2

Approximate Dimensions in Inches (mm)

1

Residential Loadcenter Knockouts
Knockouts for Box Sizes A1, B1, B2, C1, C2, C4, D1, G1, L1,
L2, B1R, B2R, C1R, C3R, D1R, G1R, L1R, L2R
Code

Diameter

A

0.50 (12.7)

0.75 (19.1)

—

—

—

B

0.50 (12.7)

—

—

—

—

C

0.50 (12.7)

1.25 (31.8)

1.50 (38.1)

2.00 (50.8)

2.50 (63.5)

D

1.25 (31.8)

1.25 (31.8)

2.00 (50.8)

2.50 (63.5)

—

E

0.50 (12.7)

0.75 (19.1)

1.00 (25.4)

—

—

F

0.50 (12.7)

0.75 (19.1)

1.00 (25.4)

1.50 (38.1)

2.00 (50.8)

G

1.25 (31.8)

1.50 (38.1)

2.00 (50.8)

—

—

H

0.50 (12.7)

0.75 (19.1)

1.00 (25.4)

1.25 (31.8)

1.50 (38.1)

2.06 (52.3) Dia.
(125A Max.)
3.06 (77.7) Dia.
(225A Max.)

1.00 (25.4)

1.25 (31.8)

1.50 (38.1)

2.00 (50.8)

2.50 (63.5)

1.00 (25.4)

1.25 (31.8)

1.50 (38.1)

—

—

1
1
1

D
E

B

E

E

1

.45 (11.4) Dia. KO

A B B
B
B
B B

A

1

D

D

E

.45 (11.4) Dia. KO

J

1

Hub

D

I

1

Residential NEMA Type 1 Indoor and
NEMA Type 3R Outdoor Enclosures

B B
B H
B B

I

A
A

1

Outdoor Boxes
B1R, B2R, C1R, C3R, D1R,
G1R, L1R, L2R
B

B

J

B

J

B

B

1

B

E

A

B

B

1

J

A

1

A

B
B

B
B

B

1

B

B

B

J

A

E

J

J

J

B

B

B

E

B

J

B

B

1

B

A

B

1

Indoor Boxes
A1
B

A
H
A

D

B

B

B

I

B

B

B

B

E

E

B

B

A A
B

1

E

D

D

1

D

E
A
B
B A
B

1

.45 (11.4) Dia. KO

.45 (11.4) Dia. KO

E
A
B
A B

A

1

B

A

E

E
D

D

D

.45 (11.4) Dia. KO
A A B B
E

B

B

B

B

I

1

A
H

B
B

B

B

1

D

.45 (11.4) Dia. KO

B

A

Indoor Boxes
B1, B2

.45 (11.4) Dia. KO
B

A
H
A

D

D

B

B

B

I

B
B

1
1

.45 (11.4) Dia. KO
B

B

B

E

E

B

A A
B

E

1

D

D

E
A
B
B A

E
A
B
A B

1

B A
B
A
E

A B
B
A
E

1

D

1

D

D

D

.45 (11.4) Dia. KO

.45 (11.4) Dia. KO

A A B B
E

B

B
B

B

B

B

I

A
H

B
B

B

1

A

Indoor Boxes
C1, C2, C4, D1, G1, L1, L2

1
1

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-67

1.2

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

1

Approximate Dimensions in Inches (mm)

1

Knockouts for Box Sizes 3, 4, 5, 6, 7, 9, 2R, 3R, 4R, 5R, 6R,
7R, 8R, 9R

1

Code

Diameter

A

0.50 (12.7)

—

—

—

1

B

0.50 (12.7)

0.75 (19.1)

—

—

1

C

0.50 (12.7)

0.75 (19.1)

1.00 (25.4)

—

D

0.50 (12.7)

0.75 (19.1)

1.00 (25.4)

1.25 (31.8)

1

E

0.75 (19.1)

1.00 (25.4)

1.25 (31.8)

—

F

0.75 (19.1)

1.00 (25.4)

1.25 (31.8)

1.50 (38.1)

1

G

1.00 (25.4)

1.25 (31.8)

1.50 (38.1)

—

H

1.00 (25.4)

1.25 (31.8)

1.50 (38.1)

2.00 (50.8)

I

1.25 (31.8)

1.50 (38.1)

2.00 (50.8)

—

1
1
1
1

Residential NEMA Type 1 Indoor and NEMA Type 3R Outdoor Enclosures
Mounting
Hole for
5/16 (7.9)
Screw

1

F

A

Hub

A

A

E

2.38
(60.3)

A

A

A

E

A

C

C

A

G
D

Box 3R

B

Hub

A

B B

A

Box 4

B

H

A

Hub

A

C

F

A

G

D

G
A A A

D

A A A

G

B

D

A

B C
A A A

G

A

G

D

D

A

F

B B

D

F

A

Box 5

Box 4R

1

1

B

G

A A A

F

F

A

1

1

A

A

A

D

D
A

A A A

A

F

A

F

Hub

D

G

Box 3

1

1

B B

A

A

F

1

A A A

A

Box 2, 2R

1

B B

A

G

G

D

.50–.75–1.00
(12.7–19.1–25.4)

.50–1.00–1.25
(12.7–25.4–31.8)

D

B

1

1

G

A

.31 (7.9)

1

1

B

A A A

.50–.75
(12.7–19.1)

6.38
(161.9)

1

1.00–1.25 KO
(25.4–31.8) KO

R

D

A

B

Hub

Hub

C
A A A

B C

F
A A A

G

A

Box 7

1

B B

C

C
G

G

F

C
A A A

B C

G

G

I

C

I

C

A A A
A

Box 7R

B B

B

I

A A

A A

B C

Box 8R

B

H

B

Hub

G

G

A

G

B

B
B
B

B

G

G

G

A

C B

D

B

Box 6R

A

A

Box 9

1
1
1
Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

G
G

A

G

G
A

C

G
B

1

V1-T1-68

F

B

B
B

D

A

H

C
G

C

A

F

Box 6

A

B B

C

Box 5R

A A A

A

G

F

F

A

B

C

B

A

B B

G

B

B

C
A

Box 9R

1.2

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Approximate Dimensions in Inches (mm)

1

Commercial Loadcenter Knockouts
NEMA Type 1 Indoor Commercial Enclosures
Knockouts for Box Sizes 19, 20, 22, 24

1

Indoor Commercial Enclosures

Code

Diameter

A

0.50 (12.7)

—

—

B

0.50 (12.7)

0.75 (19.1)

—

—

C

0.75 (19.1)

1.00 (25.4)

1.50 (38.1)

—

D

1.50 (38.1)

2.00 (50.8)

2.50 (63.5)

3.00 (76.2)

E

2.00 (50.8)

2.50 (63.5)

3.00 (76.2)

—

F

2.50 (63.5)

3.00 (76.2)

3.50 (88.9)

—

A

B B
B B B

H

E

C

1

A

B B
B B B

H

E

1

C

—

1
1
1
1

NEMA Type 3R Outdoor Commercial Enclosures
Knockouts for Box Sizes 42, 43, 46, 47

1

Code

Diameter

A

0.50 (12.7)

—

—

—

B

0.50 (12.7)

0.75 (19.1)

—

—

C

0.75 (19.1)

1.00 (25.4)

1.25 (31.8)

—

D

1.50 (38.1)

2.00 (50.8)

2.50 (63.5)

—

E

2.00 (50.8)

2.50 (63.5)

3.00 (76.2)

—

1
D

D

A

F

2.50 (63.5)

3.00 (76.2)

3.50 (88.9)

—

G

1.25 (31.8)

1.50 (38.1)

2.00 (50.8)

2.50 (63.5)

H

3.25 (82.6) Sq.

—

—

—

C

D

B B B
B B

F

D

E

E

A

E

C

E

B B B
B B

F

1

E

1

E

1

Box 22, 24

Box 19, 20

1

Outdoor Commercial Enclosures

1
HUB

Unit Enclosure Knockouts, Types ECB and ECC Knockouts
Code

HUB

HUB

HUB

1

Diameter

1

NEMA Type 1 Indoor (Flush and Surface Trims)
A

0.50 (12.7)

—

—

—

—

B

1.25 (31.8)

1.50 (38.1)

1.75 (44.5)

2.00 (50.8)

2.50 (63.5)

1

NEMA Type 3R Outdoor
A

0.50 (12.7)

—

—

—

—

B

1.25 (31.8)

1.50 (38.1)

1.75 (44.5)

2.00 (50.8)

2.50 (63.5)

1
1
1
E

D
C

E

E

D

B B B
B B

G

1

D

F

E

E

E

D

1

C B B B
B B

E

F

A

A

Box 42

1

Box 43, 46, 47

1

Unit Enclosure Knockouts
A

B

1

HUB

B

B

B

B

B

B

1
1

B

A

NEMA Type 1—Indoor

B

B
B

B

1

A

1

NEMA Type 3R—Outdoor

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-69

1.2
1
1
1
1
1
1
1
1
1
1

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Technical Data and Specifications
General
A. The Contractor shall
furnish and install
deadfront loadcenters
incorporating circuit
breakers of the number,
rating and type as
specified herein and
as shown on the
contract drawings.

Ratings
A. Loadcenters shall be
rated for 120/240 Vac and
shall have short-circuit
ratings as shown on the
drawings or
as herein scheduled,
but not less than
10,000 amperes rms
symmetrical.

B. The loadcenter and all
components shall be
designed, manufactured
and tested in accordance
with the latest applicable
standards of UL, NEMA
and NEC including:

B. Circuit breakers shall be a
minimum of 125A frame.
Circuit breakers 15
through 125A trip size
shall take up the same
pole spacing.

1. UL 67—Standards
for Panelboards.

1

C. UL 50—Standards for
Cabinets and Boxes.

1

D. UL 489—Standards for
Molded Case Circuit
Breakers.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

E. UL 869—Standards for
Service Equipment.
F. Federal Specification
W-C 375B—Circuit
Breakers.
G. Federal Specification
W-C P115b—Panel
Power Distribution
Type 1, Class 2.
Qualifications
A. The manufacturer of the
loadcenter shall be the
manufacturer of the
circuit breaker within
the loadcenter.
B. For the equipment
specified herein, the
manufacturer shall be
ISO 9000 certified.
C. The manufacturer of
this equipment shall have
produced similar
electrical equipment
for a minimum period
of seven (7) years.
Manufacturers
A. Eaton.

C. Loadcenters shall be
labeled with a UL shortcircuit rating. When
series combination
ratings are applied
with integral or remote
upstream devices, a label
shall be provided. Series
combination ratings shall
cover all trip ratings of
installed frames. It shall
state the conditions of
the UL series ratings
including:
1. Size and type of
upstream device.
2. Branch devices that can
be used.
3. UL series short
circuit rating.
Construction
A. All interiors, with the
exception of the branch
circuit breakers, shall
be completely factory
assembled with main
breakers, main lugs,
or no main device.
B. Interiors shall be
designed so that circuit
breakers can be replaced
without disturbing
adjacent units and
without removing the
main bus connectors and
shall be designed so that
circuits may be changed
without machining,
drilling, or tapping.

C. Physical means shall be
provided to prevent the
installation of more
overcurrent devices than
that number for which
the enclosure was
designed, rated and
approved. Half-size
breakers shall have a
UL listed rejection tab
over the line terminals.
Loadcenter interiors
must have notched stabs
to accept these rejection
tab class CTL breakers, if
required and approved.
Bus
A. Busbars for the main and
cross connectors shall be
[tin-plated aluminum]
[copper] in accordance
with Underwriters
Laboratories standards.
Busing shall be braced
throughout to conform to
industry standard practice
governing short-circuit
stresses in loadcenters.
Note: Note to spec writer—
select one (copper available
in limited ratings).

B. Neutral busing shall
have a suitable lug for
each outgoing feeder
requiring a neutral
connection of same
ampacity as branch.
Wiring/Termination
A. All wire connectors and
terminals shall be of the
anti-turn solderless type
and shall be suitable for
copper or aluminum wire
of the sizes indicated. All
connectors must meet
the “Requirements for
Wire Connectors and
Soldering Lugs” as
stated in UL 486B.
B. All loadcenters where
marked shall be suitable
for use with 60°C or 75°C
rated wire.

1
1
1
V1-T1-70

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

Circuit Breakers
A. Circuit breakers shall
be molded case type.
Circuit breakers shall
have four-rivet
construction (GFI Type—
5 rivets). Multipole circuit
breakers shall be of a
stack pole design to
provide electrical
phase isolation.
B. Each pole of the
circuit breaker will
provide inverse time
delay overload and
instantaneous shortcircuit protection by
means of both thermal
and magnetic sensors.
C. The circuit breaker
calibration shall
not be affected by
environmental changes
in relative humidity.
The thermal bimetal
element shall be welded
to the steel frame and
calibration shall be set
independent of the
molded case by computer
controlled equipment.
D. All circuit breakers
shall be operated by
a toggle-type handle
and multipole circuit
breakers shall have an
internal common trip
mechanism. The
circuit breakers shall
incorporate trip
mechanisms that are
mechanically trip-free
from the handle. The
handle position shall
provide visual trip
indication.
E. Contacts shall be of
non-welding silver alloy.
F. All circuit breakers shall
have the trip rating
inscribed on the handle
on each circuit breaker
pole. Also, unique colorcoded cases that indicate
the UL listed 10 kA or
22 kA interrupting
ratings. Breakers shall
be able to be used
as main or branch
disconnect devices.

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

G. Branch circuit breakers
may also be used in
the 1/2-inch (12.7 mm)
per pole ratings that
include two-pole 1-inch
(25.4 mm) wide modules
and four-pole 2-inch
(50.8 mm) wide
modules. Two-pole circuit
breakers must
incorporate a common
trip mechanism. The
exclusive CTL rejection
tab feature shall be
provided to limit the
number of branch
devices for a loadcenter
to 42, in compliance with
NEC Article 384.15.
H. Circuit breakers shall
be completely enclosed
in a molded case of
thermoset material.
No internal aluminum
parts shall be used. All
internal ferrous parts
shall be plated to
prevent corrosion.
I. All terminals shall be
listed for use with copper
or aluminum conductors.
Terminals shall be of the
box lug or clamp type
design. The terminals
shall meet UL 486B
requirements and shall
be suitable for use with
either 60°C or 75°C wire.
J. The calibrated bimetal
assembly shall be
mechanically isolated
from the load terminal
using a flexible braided
copper shunt wire, such
that movement of the
terminals due to twisting
and overtorquing does
not affect breaker
calibration.

K. Breakers shall be SWD
rated and/or HACR rated
as required.
L. Arc Fault Interrupting
circuit breakers, (AFI),
shall be provided on all
15 and 20A single-phase
120/240 Vac circuits
except those indicated as
remote controlled
breakers. AFI breakers
shall be “Classified for
mitigating the effects of
arcing faults,” or
conforming to UL
Standard 1699 and as
defined by Article 210.12
Section A of the 1999
NEC Code.
Surge Protection Devices
See Volume 1, Tab 2 for
complete details on
surge protection.
Enclosures
A. Loadcenter shall have
NEMA Type 1 general
purpose or NEMA Type
3R rainproof enclosures
as indicated on the
drawings and shall be
surface or combination
flush/surface mounted
except where noted.
B. Boxes shall be made
from galvanized sheet
steel having multiple
knockouts. Rainproof
boxes shall use
galvanized steel or
an approved coating
system which meets or
exceeds standards for
outdoor NEMA Type 3R
enclosures. Boxes shall
be of sufficient size to
provide at least a
minimum code gutter
space on all sides.

1.2

C. The deadfront shall
have an easy adjustment
feature for flush
applications.

1

D. Boxes shall be factory
assembled into a single
rigid structure.

1

1
1

E. Unless otherwise noted
on drawings, hinged
doors covering all circuit
breaker handles shall
be included in all trims.
Trim doors shall not
uncover any live parts
in making the circuit
breaker handles
accessible. If key locks
are required, all locks
shall be keyed alike.

1
1
1
1
1
1

F. Combination trims for
flush and surface panels
shall be flat and shall
overlap the box by at
least 5/8-inch (15.9 mm)
all around. Trims shall
be mounted by a
screwdriver without the
need for special tools.

1
1
1
1

Finish
A. Trims shall be bonderized
and finished with a light
gray ANSI-61 enamel.
The paint finish shall be
of a type to which field
applied paint will adhere.

1
1
1

Factory Testing
A. The standard factory
tests shall be performed
on the equipment
provided under this
section. All tests shall
be in accordance with
the latest version of UL
and NEMA.

1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-71

1.2
1

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Contents—BR Specialty Products

Type BR Retrofit Interior

Description

1

Page

Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BR Specialty Products
Spa Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Riser Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type BR Renovation Loadcenter . . . . . . . . . . .
Type BR Mechanical Interlock Kits . . . . . . . . . .
Type BR Retrofit Interior Kits
BR Circuit Breakers. . . . . . . . . . . . . . . . . . . . . . . .

1
1
1
1

V1-T1-42
V1-T1-57
V1-T1-58
V1-T1-59
V1-T1-61
V1-T1-75

1
1

Type BR Retrofit
Adjustable Interior

Type BR Retrofit Interior Collar
and Assembly with Trim

1
1
1

Type BR Retrofit Interior Kits

1

Product Description

Application Description

Eaton’s unique Retrofit
Interior allows the customer
to cost-effectively and safely
upgrade an electrical service
without removing the existing
enclosure from the wall.

The Retrofit Interior is
designed and tested
specifically for renovating
an outdated electrical panel in
an apartment, a condominium
or a single family home.
These outdated panels are
being recognized by local
inspectors and other
authorities as a possible
hazard.

1
1
1
1
1
1
1
1
1
1
1

Quick-ProSM
All you need to
know to save
time and make
more money.
Specified on certain Eaton
products, the Quick-Pro
symbol allows for immediate
recognition of products
that are designed for
straightforward installation.
When you see Quick-Pro,
you know you can install
quickly—sometimes up to
50% less than the usual
installation time—and move
on to your next job.

1
1
1
1
1

Opportunities to Retrofit
●
Single- or three-phase
●
Main lug only or main
breaker
●
Up to 42 circuits
●
Up to 225A interiors,
400A available upon
request
●
Available with CH breakers
(3/4-inch) with copper bus
or BR breakers (1-inch) with
aluminum bus
●
The minimum lifetime
warranty for residential
breakers shall be as
follows:
●
10-year warranty on all
BR branch breakers and
loadcenters
●
Refer to Eaton for
complete warranty
details

Features and Benefits
Upgrading Existing Electrical
Infrastructure Is Simple
●
Replaces vintage brands
that have hard to find,
expensive replacement
breakers
●
Safety upgrade to arc fault
and ground fault breakers
to meet current electrical
codes
●
Maximizes number of
circuits available with
compact design
●
Eco-friendly in asbestosfilled environments
●
Exclusive design
Save Time and Money
Throughout the Installation
●
Uses existing panel
box and wires
●
Eliminates expensive and
time-consuming drywall/
paint repair
●
Saves 2–3 hours of
installation time compared
to a complete panel
changeout
●
Eliminates precise
measurements with fieldadjustable kit

1
1
V1-T1-72

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

Detailed Product Guide
All standard retrofit kits are
suitable for a range of
existing box sizes:
●

●

●

Box width ranging from
14.50 to 22.00 inches
(368.3 to 558.8 mm)
Box depth ranging from
4.00 inches (101.6 mm)
for BR
Box height ranging from
21.00 to 45.00 inches
(533.4 to 1143.0 mm)

For box dimensions outside
of these ranges, contact
the Lincoln Flex Center at
800-330-6479. Be sure to
provide the existing incoming
line wire size.

Standards and Certifications
●

●

Meets 2008/2011/2014
NEC wire bending
requirements
UL 67 Listed (for UL
listings for specific part
numbers, see the table on
the following page.

1.2

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

BR Specialty Product Selection

1

To select the retrofit kit:
1. From the existing box
size determine which
retrofit groups are
suitable (may be more
than one).
2. Use type of interior,
number of phases, and
type of main to find the
selection chart.
3. Select part number from
chart (if main breaker,
replace XXX with specific
amp rating).

4. Note that the overlap
of the existing wall is
the retro cover size
minus the existing
box size. If specific
measurements are
needed, communicate
that you need a custom
trim size.
5. Contact the Lincoln Flex
Center at 800-330-6479
for pricing, lead-times,
and order entry
instructions.

How to Order:
1. Measure the existing
panel enclosure to
determine appropriate
kits for your project.

Need assistance or can’t find
retrofit to fit existing
enclosure?

2. Match the existing
dimensions with the
table below to obtain the
correct catalog number.
3. Order your retrofit kit
from a local Eaton
authorized distributor.

Call Eaton’s Residential Flex
Center at 1-800-330-6479
or email for all your retrofit
needs. Go to
www.eaton.com/eccn to
locate an Eaton Certified
Contractor.

1
1
1

1

Minimum
Depth

Maximum
Depth

Minimum
Width

Minimum
Height

Phase

Main

Bus

Amperes 3

Spaces /
Circuits

UL 67
Listed

CRTBR8ML****

3.13 (79.5)

3.63 (92.2)

10.50 (266.7)

13.00 (330.2)

Single

MLO

BR

100

16

Yes

RUBR8L100_

CRUBR8ML****

3.75 (95.3)

6.00 (152.4)

10.50 (266.7)

13.00 (330.2)

Single

MLO

BR

100

16

Yes

RTBR12L100P

CRTBR12ML****

3.13 (79.5)

3.63 (92.2)

10.50 (266.7)

14.50 (368.3)

Single

MLO

BR

100

24

Yes

RTBR10B100P

CRTBR12ML****

3.13 (79.5)

3.63 (92.2)

10.50 (266.7)

14.50 (368.3)

Single

MLO

BR

100

20

Yes

RUBR12L100_

CRUBR12ML****

3.75 (95.3)

6.00 (152.4)

10.50 (266.7)

14.50 (368.3)

Single

MLO

BR

100

24

Yes

RUBR10B100_

CRUBR12ML****

3.75 (95.3)

6.00 (152.4)

10.50 (266.7)

14.50 (368.3)

Single

MB

BR

100

20

Yes

RTBR12L125P

CRTBR12ML****

3.13 (79.5)

3.63 (92.2)

11.00 (279.4)

17.00 (431.8)

Single

MLO

BR

125

24

Yes

RTBR10B125P

CRTBR12ML****

3.13 (79.5)

3.63 (92.2)

11.00 (279.4)

17.00 (431.8)

Single

MB

BR

125

20

Yes

RUBR12L125_

CRUBR12ML****

3.75 (95.3)

6.00 (152.4)

11.00 (279.4)

17.00 (431.8)

Single

MLO

BR

125

24

Yes

RUBR10B125_

CRUBR12ML****

3.75 (95.3)

6.00 (152.4)

11.00 (279.4)

17.00 (431.8)

Single

MB

BR

125

20

Yes

RABR20B125_

CRABR20ML****

3.75 (95.3)

6.00 (152.4)

13.00 (330.2)

21.00 (533.4)

Single

MCB

BR

125

24

No

RABR20L125_

CRABR20ML****

3.75 (95.3)

6.00 (152.4)

13.00 (330.2)

21.00 (533.4)

Single

MLO

BR

125

24

No

RBBR20B200_

CRBBR20BW****

3.75 (95.3)

6.00 (152.4)

13.00 (330.2)

29.00 (736.6)

Single

MLO

BR

200

40

No

RCBR40L200_

CRCBR40ML****

3.75 (95.3)

6.00 (152.4)

13.00 (330.2)

34.00 (863.6)

Single

MLO

BR

200

40

No

RDBR40B200_

CRDBR40BW****

3.75 (95.3)

6.00 (152.4)

13.00 (330.2)

37.00 (939.8)

Single

MLO

BR

200

40

No

BR Retrofit Interiors and Covers
RTBR8L100P

1

1

Existing Enclosure Parameters—Inches (mm)
Cover 2

1

1

Retrofit Interior Kit Specifications
Five recommended groups: existing box height determines retro group size. Approximate Dimensions in Inches (mm).
Catalog
Number 1

1

Notes
1 Catalog numbers shown with "_" at the end need one of the following suffixes to denote depth:
J = 3.75–4.25
K = 4.25–5.00
L = 5.00–6.00
Example: RTBR12L125J would signify an interior set with a depth range of 3.75 to 4.25 inches.
2 ****Denotes characters in the catalog number that relate to overall cover size.
Example: CRTBR12ML2620 would signify a cover 26.00 inches H x 20.00 inches W.
3 Amperes for MB panels is maximum; catalog number will reflect actual amperage of breaker included.

1
1
1
1
1
1
1
1
1
1
1
1
1
1

For UL applications, maximum cover sizes may apply.

1
1
1
1
1
1
Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-73

1.2
1
1
1
1

Note: For complete assembly,
interior and cover need to be
ordered separately.

Adjustable Interior
●

●

1

●

1

Type BR Loadcenters and Circuit Breakers

Complete Assembly

1
1

Loadcenters and Circuit Breakers

●

Factory installed ground
and neutral bars positioned
to accept existing wires
Field adjustable depth
matches existing panel box
Adjustable height enables
optional placement of the
interior
Field bondable for service
entrance options

Standard Trim and Collar
●

●

●

Standard trim matches
new interior
New circuit directory for
updated labeling
Oversized collar eliminates
expensive wall/paint repair

1
1
1

Adjustable Interior

Collar and Assembly with Trim

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
V1-T1-74

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

1.2

Contents

BR Circuit Breakers

Description

Page

Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BR Specialty Products
Spa Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Riser Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type BR Renovation Loadcenter . . . . . . . . . . .
Type BR Mechanical Interlock Kits . . . . . . . . . .
Type BR Retrofit Interior Kits . . . . . . . . . . . . . .
BR Circuit Breakers
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
Circuit Breaker Accessories . . . . . . . . . . . . . . .
Wiring Diagrams. . . . . . . . . . . . . . . . . . . . . . . .

V1-T1-42
V1-T1-57
V1-T1-58
V1-T1-59
V1-T1-61
V1-T1-72
V1-T1-76
V1-T1-84
V1-T1-86

1
1
1
1
1
1
1
1
1
1

BR Circuit Breakers

1

Product Description

1

Plug-On Branch Feeder Type
Arc Fault Circuit Breakers,
Type BR—10 kAIC, 120 Vac
and 120/240 Vac
A branch feeder type arc fault
circuit interrupter is a device
intended to mitigate high
current arcing faults in the
complete circuit, including
connected cords. High
current arcing faults can
occur from line to neutral or
line to ground. These arcing
faults are in parallel with the
load and produce the most
energy of all arcing faults.
The branch feeder type AFCI
is required in the 1999 and
2002 National Electrical Code.
The Combination Type AFCI is
required in the 2005, 2008, and
2011 National Electrical Code.

Plug-On Combination Type
Arc Fault Circuit Breakers,
Type BR—10 kAIC, 120 Vac
and 120/240 Vac
A combination type arc
fault circuit interrupter is a
device that includes all of
the protection offered by the
branch feeder AFCI (mitigation
of high current arcing faults in
the complete circuit, including
connected cords). In addition
it provides direct detection of
persistent low current arcing
faults down to 5 amps with
associated mitigation of
fire hazards in the cords
connected to the outlets. High
current arcing faults can occur
from line to neutral or line to
ground. These arcing faults
are in parallel with the load
and produce the most energy
of all arcing faults. The current
level of low current arcing
faults is limited by the load.

Plug-On Ground Fault Circuit
Breakers, Type GFCB and
GFEP—10/22 kAIC, 120 Vac
and 120/240 Vac
Ground Fault
Application Notes
Single-pole GFCBs are
designed for use in twowire, 120 Vac circuits. See
Page V1-T1-86 for a typical
wiring configuration.
Two-pole GFCBs are
designed for use in threewire, 120/240 Vac circuits,
120 Vac multiwire circuits
employing common, neutral
and two-wire, 240 Vac
circuits obtained from a
120/240 Vac source.
Page V1-T1-86 shows typical
wiring configurations for a
120/240 Vac multiwire
circuits, and a 240 Vac, twowire circuit. Note the “panel
neutral” conductor connects
to the neutral bar, even
though the neutral is not
included in the load circuit.
This connection is necessary
to supply a 120 Vac power
source to the ground fault
sensing circuit.

The figures are shown with
a 120/240 Vac, single-phase,
three-wire power source,
but are also applicable to a
120/208 Vac, three-phase,
four-wire power supply.
For all figures, the electrical
operation of the GFCB is
not affected by the
equipment ground.

1

Non-CTL Plug-On Replacement
—Circuit Breakers, Type BRD—
10 kAIC, 120/240 Vac

1

Non-CTL 10 kAIC
for Replacement
Purposes Only
For replacement in
enclosures manufactured
prior to 1968 with unnotched
stabs. Circuit breakers do
not have rejection tab.

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-75

1.2

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

1

Product Selection

1

Plug-On Circuit Breakers, Types BR—10/22/42 kAIC, 120 Vac, 120/240 Vac and 240 Vac

1

BR120

Type BR Breakers, 1-Inch (25.4 mm) per Pole 120/240, 10, 22 and 42 kAIC

1
1

Single-Pole 120/240 Vac
Requires One 1-Inch (25.4 mm) Space

Two-Pole 120/240 Vac
Common Trip Requires Two
1-Inch (25.4 mm) Spaces

10 per Shelf Carton

5 per Shelf Carton

10 kAIC

22 kAIC

10 kAIC

22 kAIC

42 kAIC

Catalog
Number

Catalog
Number

Catalog
Number

Catalog
Number

Ampere
Rating

Wire Size Range
Cu/Al 60°C or 75°C

Catalog
Number

10

#14–4

BR110

—

BR210

—

—

15

#14–4

BR115 12

BRH115

BR215 3

BRH215

—

20

#14–4

BR120 12

BRH120

BR220 3

BRH220

—

25

#14–4

BR125

BRH125

BR225 3

BRH225

—

1

30

#14–4

BR130

BRH130

BR230 3

BRH230

—

35

#14–4

BR135

BRH135

BR235 3

BRH235

—

1

40

#14–4

BR140

BRH140

BR240 3

BRH240 3

—

45

#14–4

—

BRH145

BR245 3

BRH245

—

50

#14–4

BR150

BRH150

BR250 3

BRH250 3

—

1

55

#14–3

BR150

BRH155

BR255

BRH255

—

60

#8–1/0

BR160

BRH160

BR260

BRH260

BRHH260

1

70

#8–1/0

BR170

BRH170

BR270

BRH270

BRHH270

80

#8–1/0

—

—

BR280

BRH280

BRHH280

90

#8–1/0

—

—

BR290

BRH290

BRHH290

100

#8–1/0

—

—

BR2100

BRH2100

BRHH2100

110

#8–1/0

—

—

BR2110

BRH2110

BRHH2110

125

#4–2/0

—

—

BR2125

BRH2125

BRHH2125

150

#4–2/0

—

—

BR2150 4

—

—

1
1

BR215

1

BR320

1

1

BRH2100

1
1
1

Notes
1 One pole, 1-inch (25.4 mm) per pole circuit breakers are available with high magnetic setting for switching large tungsten lamp loads. Add suffix H to catalog number.
2 Switching duty rated.
3 On the black handle breaker, add suffix “B” to the catalog number to obtain a tapped molded opening for proper use with hold-down kits.
4 For use as a branch circuit breaker in 400 and 600 ampere panels only.

1
1
1

All Type BR single-, two- and three-pole circuit breakers carry listing for HACR application. For circuit breakers with a shunt trip, add ST suffix.

1
1
1
1
1
1
1
1
1
1
V1-T1-76

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

BR Breakers

1.2

Type BR Breakers, 1-Inch (25.4 mm) per Pole 240 Vac, 10, 22 and 42 kAIC

1

Three-Pole 240 Vac
Common Trip Requires Three
1-Inch (25.4 mm) Spaces

1

5 per Shelf Carton
Ampere
Rating

Wire Size Range
Cu/Al 60°C or 75°C

10 kAIC

22 kAIC

Catalog Number

Catalog Number

10

#14–4

BR310

—
1

BRH315
BRH320

15

#14–4

BR315

20

#14–4

BR320 1

25

#14–4

BR325

BRH325

30

#14–4

BR330

BRH330

35

#14–4

BR335

BRH335

40

#14–4

BR340

BRH340

45

#14–4

BR345

BRH345

50

#14–4

BR350

BRH350

55

#14–3

BR355

BRH355

60

#4–1/0

BR360

BRH360

70

#4–1/0

BR370

BRH370

80

#4–1/0

BR380

BRH380

90

#4–1/0

BR390

BRH390

100

#4–1/0

BR3100

BRH3100

1
1
1
1
1
1
1
1
1
1
1

Plug-On Branch Feeder Type Arc Fault Circuit Breakers, Type BR—10 kAIC, 120 Vac and 120/240 Vac

1

Type BR, 1-Inch (25.4 mm) Wide FIRE-GUARD AFCI Circuit Breakers

1

Type BR AFCI
Circuit Breaker

Ampere
Rating

Configuration

Catalog
Number

Single-pole
10 kAIC

15

AFCI

BR115AF 2

20

AFCI

BR120AF 2

Single-pole
22 kAIC

15

AFCI

BRH115AF

Poles

Two-pole
10 kAIC 34

20

AFCI

BRH120AF

15

AFCI Common Trip

BRL215AF

20

AFCI Common Trip

BRL220AF

1
1
1
1

Notes
1 One pole, 1-inch (25.4 mm) per pole circuit breakers are available with high magnetic setting for switching large tungsten lamp loads. Add suffix H to catalog number.
2 Clamshell packaging available with CS modification code on the end of catalog number.
3 Common trip refers to two-pole 240V load application sourced by 120/240 Vac (see Page V1-T1-86).
4 Independent trip refers to two-pole multi-wire, home run or shared neutral circuits (see Pages V1-T1-86 and V1-T1-87).
All Type BR single-, two- and three-pole circuit breakers carry listing for HACR application. For circuit breakers with a shunt trip, add ST suffix.

1
1
1
1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-77

1.2

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

1

Plug-On Combination Type Arc Fault Circuit Breakers, Type BR—10 kAIC, 120 Vac and 120/240 Vac

1

BRCAF115

Type BR, 1-Inch (25.4 mm) wide FIRE-GUARD Combination Type AFCI
Circuit Breakers

1

Poles

1

Single-pole
10 kAIC

Ampere
Rating

AFCI

BRCAF115 1
BRACAF115

AFCI

BRCAF120 1

Diagnostic AFCI

BRACAF120

15

AFCI

BRHCAF115 1

20

AFCI

BRHCAF120 1

15

AFCI

BRL215CAF

20

AFCI

BRL220CAF

20

1

Single-pole
22 kAIC

1

Two-pole
10 kAIC

1

Catalog
Number

Diagnostic AFCI

15

1

Configuration

1

Plug-On Ground Fault Circuit Breakers, Type GFCB and GFEP—10/22 kAIC, 120 Vac and 120/240 Vac

1

Type GFCB Single-Pole

1

Type GFCB Ground Fault Circuit Breakers—5 Milliampere—
1-Inch (25.4 mm) per Pole 120 Vac or 120/240 Vac, 10 kAIC

1

Single-Pole 120 Vac
Requires One
1-Inch (25.4 mm) Space

1

Two-Pole 120/240 Vac
Common Trip Requires Two
1-Inch (25.4 mm) Spaces

Ampere
Rating

Wire Size Range
Cu/Al 60°C or 75°C

1 per Shelf Carton

1 per Shelf Carton

Catalog Number 2

Catalog Number

1

15

#14–4

GFCB115

GFCB215

20

#14–4

GFCB120

GFCB220

1

25

#14–4

GFCB125

GFCB225

30

#14–4

GFCB130

GFCB230

1

40

#14–4

GFCB140

GFCB240

1

50

#14–4

—

GFCB250 3

60

#14–6

—

GFCB260

1

Type GFCB Two-Pole

1

Notes
1 Clamshell packaging available with CS modification code on the end of catalog number.
2 Available with bell alarm or auxiliary switch. See circuit breaker accessories on Page V1-T1-84.
3 For use with copper wire only.

1
1
1
1
1
1
1
1
1
1
1
V1-T1-78

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

1.2

Type GFCBH Ground Fault Breakers—5 Milliampere—
1-Inch (25.4 mm) per Pole 120 Vac or 120/240 Vac, 22 kAIC

1
1

Single-Pole 120 Vac
Requires One
1-Inch (25.4 mm) Space

Two-Pole 120/240 Vac
Common Trip Requires Two
1-Inch (25.4 mm) Spaces

Ampere
Rating

Wire Size Range
Cu/Al 60°C or 75°C

1 per Shelf Carton

1 per Shelf Carton

Catalog Number

Catalog Number

15

#14–4

GFCBH115

GFCBH215

20

#14–4

GFCBH120

GFCBH220

25

#14–4

GFCBH125

GFCBH225

30

#14–4

GFCBH130

GFCBH230

1
1
1
1
1
1

Type GFEP Ground Fault Equipment Protectors—30 Milliampere—
1-Inch (25.4 mm) per Pole 120 Vac or 120/240 Vac, 10 kAIC

1
1

Single-Pole 120 Vac
Requires One
1-Inch (25.4 mm) Space

Two-Pole 120/240 Vac
Common Trip Requires Two
1-Inch (25.4 mm) Space

Ampere
Rating

Wire Size Range
Cu/Al 60°C or 75°C

1 per Shelf Carton

1 per Shelf Carton

Catalog Number

Catalog Number

15

#14–4

GFEP115

GFEP215

20

#14–4

GFEP120

GFEP220

25

#14–4

GFEP125

GFEP225

30

#14–4

GFEP130

GFEP230

40

#14–4

—

GFEP240

50

#14–4

—

GFEP250 1

1
1
1
1
1
1
1

Note
1 For use with copper wire only.

1
1
1
1
1
1
1
1
1
1
1
1
1
Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-79

1.2

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

1

CTL Plug-On Circuit Breakers, Type BD Duplex, BQ and BQC Quadplex—10 kAIC, 120/240 Vac

1

BD2020

1

Type BQ Quadplex Independent Trip
(UL Type BRD)

Single-Pole 1
Requires One 1-Inch
(25.4 mm) Space
10 per Shelf Carton

1

120 Vac

BQ2302115

Type BQ Quadplex Independent Trip
(UL Type BRD)

120 Vac
120/240 Vac
120 Vac

120/240 Vac
120/240 Vac

1
1

Class CTL, 1-Inch (25.4 mm) per Pole 10 kAIC—All Circuit Breakers Have Rejection Tab Feature
Type BD Duplex
(UL Type BRD)

120/240 Vac
120/240 Vac

Two-Pole 2 and Single-Pole 1
Requires Two 1-Inch
(25.4 mm) Spaces
5 per Shelf Carton
120 Vac

120/240 Vac

Two-Pole
Requires Two 1-Inch
(25.4 mm) Spaces
5 per Shelf Carton
120 Vac

120/240 Vac

1

Ampere
Rating

Catalog
Number

Wire Size
Range
Cu/Al
65°C or 75°C

1

10–10

BD1010

#14–4

15

20

15

BQ2202115 15

15

BQ215215

15–15

BD1515

#14–4

20

20

20

BQ2202120 15

20

BQ215220

15–20

BD1520

#14–4

15

30

15

BQ2302115 15

30

BQ215230

15–30

BD1530

#14–4

20

30

20

BQ2302120 15

40

BQ215240

20–15

BD2015

#14–4

15

40

15

BQ2402115 15

50

BQ215250

1

20–20

BD2020

#14–4

20

40

20

BQ2402120 20

20

BQ220220

20–30

BD2030

#14–4

15

50

15

BQ2502115 20

30

BQ220230

1

25–25

BD2525

#14–4

20

50

20

BQ2502120 20

40

BQ220240

30–15

BD3015

#14–4

—

—

—

—

20

50

BQ220250

1

30–20

BD3020

#14–4

—

—

—

—

25

25

BQ225225

1

30–30

BD3030

#14–4

—

—

—

—

30

30

BQ230230

30–40

BD3040

#14–4

—

—

—

—

30

40

BQ230240

1

30–50

BD3050

#14–4

—

—

—

—

30

50

BQ230250

50–30

BD5030

#14–4

—

—

—

—

40

40

BQ240240

1

50–50

BD5050

#14–4

—

—

—

—

40

50

BQ240250

—

—

—

—

—

—

—

50

50

BQ250250

1
1

BQ230230

1

Ampere Rating

Ampere Rating

Outer Left
Center Two-Pole Outer Right Catalog
Single-Pole Independent Trip Single-Pole Number

Outer Two-Pole Center Two-Pole Catalog
Independent Trip Independent Trip Number

Notes
1 All 15 and 20A single poles are switch-duty rated.
2 All Type BD duplex and BQ quadplex circuit breakers carry listing for HACR applications.

1
1
1
1
1
1
1
1
1
1
1
1
1
V1-T1-80

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

1.2

Non-CTL Plug-On Replacement—Circuit Breakers, Type BRD—10 kAIC, 120/240 Vac
BR2020

1

Class Non-CTL, 1-Inch (25.4 mm) per Pole 10 kAIC—Breakers Do Not Have Rejection Tab Feature
Type BR Duplex

120/240 Vac
120/240 Vac
120/240 Vac

120 Vac
Ampere
Rating

Catalog
Number

Wire Size
Range
Cu/Al
65°C or 75°C

15–15

BR1515

15–20
20–15

1

120/240 Vac

120/240 Vac

Single-Pole Requires One
1-Inch (25.4 mm) Space
10 per Shelf Carton

1

Type BRD Quadplex Common Trip
Center and Outer Poles

Type Brand BRD Quadplex Independent Trip

120/240 Vac

Two-Pole Requires Two
1-Inch (25.4 mm) Spaces
5 per Shelf Carton

Two-Pole Requires Two
1-Inch (25.4 mm) Spaces
5 per Shelf Carton

120/240 Vac

120/240 Vac

120/240 Vac

Ampere Rating

1
1

Ampere Rating

Outer Two-Pole
Independent Trip

Center Two-Pole
Independent Trip

Catalog
Number

Outer Two-Pole
Common Trip

Center Two-Pole
Common Trip

Catalog
Number

#14–4

15

15

BR415

15

15

BRDC215215

BR1520

#14–4

20

20

BR420

30

30

BRDC230230

BR2015

#14–4

30

30

BR430

30

40

BRDC230240

20–20

BR2020

#14–4

20

30

BRD220230

30

50

BRDC230250

30–30

BR3030

#14–4

30

40

BRD230240

—

—

—

30–50

BR3050

#14–4

30

50

BRD230250

—

—

—

Unnotched
Bus Stab

1
1
1
1

Type BR or Type BD Duplex, (CTL),
Type BQ and
BQC Quadplex

CTL Circuit
Limiting
Feature

1

Type BD
Duplex

1

Rejection
Tab
Type BR

1

1

CTL and Non-CTL Breakers

Notched
Bus Stab

1

Notched
Stab

Non-CTL
Non-Circuit
Limiting

1

Type BR

1
1
1

Note
Type BD Duplex, BQ and BQC Quadplex circuit breakers can be installed in Circuit Limiting (CTL) listed BR loadcenters. Type BR twin breakers can be installed in
Non-CTL BR loadcenters.

1
1
1
1
1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-81

1.2

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

1

Common Trip Quadplex Breakers

1

BQC2302115

1

Type BQC Quadplex Common Trip Center and Outer Poles
(UL Type BRD)

120 Vac
120/240 Vac
120 Vac

1

120/240 Vac
120/240 Vac

Two-Pole 1 and Single-Pole 2
Requires Two 1-Inch (25.4 mm) Spaces
5 per Shelf Carton

1
1

Class CTL, 1-Inch (25.4 mm) per Pole 10 kAIC—All Circuit Breakers Have Rejection Tab Feature
Type BQC Quadplex Common Trip Center Poles
(UL Type BRD)

120 Vac

120/240 Vac

Two-Pole 1
Requires Two 1-Inch (25.4 mm) Spaces
5 per Shelf Carton

120 Vac

120/240 Vac

Ampere Rating

Ampere Rating
Outer Two-Pole
Common Trip

Center Two-Pole
Common Trip

Catalog
Number

Outer Left
Single-Pole

Center Two-Pole
Common Trip

Outer Right
Single-Pole

Catalog
Number

Wire Size Range
Cu/Al 65°C
or 75°C

15

20

15

BQC2202115

#14–4

15

15

BQC215215

1

15

25

15

BQC2252115

#14–4

15

20

BQC215220

1

15

30

15

BQC2302115

#14–4

15

30

BQC215230

15

40

15

BQC2402115

#14–4

20

15

BQC220215

1

15

50

15

BQC2502115

#14–4

20

20

BQC220220

—

—

—

—

#14–4

20

30

BQC220230

1

—

—

—

—

#14–4

20

40

BQC220240

1

—

—

—

—

#14–4

20

50

BQC220250

20

15

20

BQC2152120

#14–4

25

25

BQC225225

1

20

20

20

BQC2202120

#14–4

25

30

BQC225230

20

25

20

BQC2252120

#14–4

30

15

BQC230215

1

20

30

20

BQC2302120

#14–4

30

30

BQC230230

20

40

20

BQC2402120

#14–4

30

40

BQC230240

1

20

50

20

BQC2502120

#14–4

30

50

BQC230250

1

30

50

20

BQC2502030

#14–4

40

30

BQC240230

—

—

—

—

#14–4

40

40

BQC240240

1

—

—

—

—

#14–4

40

50

BQC240250

—

—

—

—

#14–4

50

20

BQC250220

1

—

—

—

—

#14–4

50

50

BQC250250

BQC2302115

1

Notes
1 All Type BQC quadplex circuit breakers carry listing for HACR applications.
2 All 15 and 20 ampere single poles are switch-duty rated.

1
1
1
1
1
1
1
1
1
1
1
1
V1-T1-82

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

1.2

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Plug-On Circuit Breakers, Types BJ and BJH—10/22 kAIC, 120/240 Vac and 240 Vac
For Use in Single-Phase and Three-Phase Loadcenters—150 Amperes and Above
Type BJ

1
1

Types BJ and BJH Breakers, 1-Inch (25.4 mm) per Pole, 120/240 or 240 Vac, 10, 22 kAIC

1
1

Three-Pole 240 Vac
Common Trip Requires Six
1-Inch (25.4 mm) Spaces 2
5 per Shelf Carton

Two-Pole 120/240 Vac
Common Trip Requires Four
1-Inch (25.4 mm) Spaces 1
10 per Shelf Carton
Ampere
Rating

10 kAIC

22 kAIC

Catalog Number

125
150

1

10 kAIC

22 kAIC

Catalog Number

Wire Size Range
Cu/Al 60°C or 75°C

Catalog Number

Catalog Number

BJ2125

BJH2125

#2–300 kcmil

BJ3125

BJH3125

BJ2150

BJH2150

#2–300 kcmil

BJ3150

BJH3150

175

BJ2175

BJH2175

#2–300 kcmil

BJ3175

BJH3175

200

BJ2200

BJH2200

#2–300 kcmil

BJ3200

BJH3200

225

BJ2225

BJH2225

#2–300 kcmil

BJ3225

BJH3225

1
1
1
1

Plug-On Special Application Circuit Breakers—10 kAIC, 120 Vac, 120/240 Vac and 240 Vac
BRWH215
Water Heater Breaker

1

Special Application Circuit Breakers, 1-Inch (25.4 mm) per Pole
Water Heater Breakers

Switching Neutral Breakers

LINE

240V Breakers

Non-Automatic Molded Case Switches

NEUTRAL

BRSN220
Switching Neutral
Breaker

1
1

OUT
IN

LOAD

1

Two-Pole 120/240 Vac
Common Trip Requires Two
1-Inch (25.4 mm) Spaces

Two-Pole 120 Vac
Common Trip Requires Two
1-Inch (25.4 mm) Spaces

With Isolated Line Terminals
for Separately Metered
Water Heaters

With Switching Neutral Pole
for Gasoline Pump Applications

Ampere
Rating

Catalog
Number

Ampere
Rating

Catalog
Number

Wire
Size
Range
Cu/Al
60°C or
75°C

15

BRWH215

15

BRSN215

20

BRWH220

20

30

BRWH230

25

—

—

—

—

—
—

5 per Shelf Carton

5 per Shelf Carton

10 kAIC

10 kAIC

1

Two-Pole 240 Vac
Common Trip Requires Two
1-Inch (25.4 mm) Spaces

Two-Pole 240 Vac
Requires Two
1-Inch (25.4 mm) Spaces

Where Voltage to
Ground is 240 Vac

For Use as Disconnect Contains No
Magnetic or Thermal Trip Properties

5 per Shelf Carton

5 per Shelf Carton

10 kAIC

5 kAIC

Ampere
Rating

Catalog
Number

Ampere
Rating

Catalog
Number

#14–4

10

BR210H

—

—

BRSN220

#14–4

15

BR215H

—

—

BRSN225

#14–4

20

BR220H

—

—

30

BRSN230

#14–4

25

BR225H

—

—

—

—

#14–4

30

BR230H

—

—

—

—

—

#14–4

35

BR235H

—

—

—

—

—

#14–4

40

BR240H

—

—

—

—

—

—

#14–4

45

BR245H

—

—

—

—

—

—

#14–4

50

BR250H

50

BR250NA

—

—

—

—

#14–4

55

BR255H

—

—

—

—

—

—

#4–1/0

60

BR260H

60

BR260NA

—

—

—

—

#4–1/0

70

BR270H

—

—

—

—

—

—

#4–1/0

80

BR280H

—

—

—

—

—

—

#4–1/0

90

BR290H

—

—

—

—

—

—

#4–1/0

100

BR2100H

100

BR2100NA

1
1
1
1
1
1
1
1
1
1
1
1
1

Notes
1 Breaker uses two 1-inch (25.4 mm) pole spaces on left side and two 1-inch (25.4 mm) pole spaces on right side of loadcenter.
2 Breaker uses three 1-inch (25.4 mm) pole spaces on left side and three 1-inch (25.4 mm) pole spaces on right side of loadcenter.

1

If BJ or BJH breakers are used as a main or a back feed device, a hold-down kit is required. See Page V1-T1-84.

1
1
Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-83

1.2
1
1

THS1

Ordering
Quantity 1

Catalog
Number

Handle tie bar for physically joining the handles of two adjacent single-pole Type BR circuit breakers (metal cylinder pin type)

10

BHT

Handle tie bar for joining two independent outside poles of Types BQ and BQC Quadplex and outside poles of two Type BD
duplex circuit breakers

10

THOW

Handle Ties 2

BHLW2

1

Handle tie bar for joining two adjacent outside poles of Types BQ and BQC Quadplex and outside poles of two Type BD duplex circuit breakers 10
BRQLW

1
1

Field Installation Kits and Parts
Description

1

1

Type BR Loadcenters and Circuit Breakers

Circuit Breaker Accessories

1
1

Loadcenters and Circuit Breakers

MCBPL (Installed)

Handle Lockoffs

THS1

34

Padlockable device for locking the handle of single-, two- or three-pole Type BR Circuit Breakers and single-pole of a Type BD Duplex
or one independent outside pole of a Type BQ or BQC Quadplex circuit breakers (escutcheon mounted) 5

10

BRLW

Padlockable device for locking the handle of a single-pole Type BR circuit breaker (handle mounted) 6

10

BRLW1

10

BRLW2

10

BRDL1

Padlockable device for locking the handle of a two- and three-pole Type BR circuit breaker (handle mounted)

6

1

Padlockable device for locking the handle of a single-pole Type BD Duplex, BQ or BQC Quadplex breaker (handle

1

Padlockable device for locking the handle of the two center poles and the two outer poles of a two-pole Types BQ and BQC quadplex
circuit breakers (escutcheon mounted) 5

10

BRQLW

1

Padlockable device for locking the handle of main circuit breaker Types CC and CHH into the ON or OFF position (screw mounted) 7

1

CCPL

Padlockable device for locking the handle of main breaker Types BW and CSR into the ON or OFF position (escutcheon Mounted) 5

1

MCBPL

Device used to secure handle in ON or OFF position for single-, two- or three-pole Type BR circuit breakers and single-pole of Type BD
duplex and one independent outside pole of Type BQ or BQC Quadplex circuit breakers (escutcheon mounted) 5

10

BHLW

Device used to secure handle in ON or OFF position for single-pole Type BR circuit breakers (handle mounted) 6

10

BHLW1

Device used to secure handle in ON or OFF position for two- and three-pole Type BR circuit breakers (handle mounted) 6

10

BHLW2

1

Device used to secure handle in ON or OFF position for single-pole Type GFCB ground fault circuit breakers (handle mounted) 6

10

BHGW

1

Device used to secure handle in ON or OFF position for one independent outside pole of Types BQ and BQC Quadplex or single-pole
Type BD duplex circuit breakers (handle mounted) 6

10

HLW1

Hold-down retainer kit for three-pole Type BR circuit breakers in S3100 and 3100R loadcenters only

1

BRHDB

Hold-down screw kit for two- and three-pole Type BR circuit breakers in single-phase MLO loadcenters through 100–125A

1

BREQS125

Hold-down screw kit for two- and three-pole Type BR circuit breakers in MLO loadcenters 150–225A

1

BRHDK125

Hold-down screw kit for two-pole Types BJ and BJH circuit breakers in MLO loadcenters 125–225A

1

BJHDS

Hold-down screw kit for three-pole Types BJ and BJH circuit breakers in MLO loadcenters 125–225A

1

BJHDS3P

Types CC and CHH main breaker lug kit (2) 300 kcmil

1

CCL300

Types BW/CSR main breaker lug kit (2) 300 kcmil

1

MCBL300

1

BHLW

1
1

1

BRLW2

BREQS125

1
1
1

mounted) 6

Hold-Down Kits 8

BRHDK125

1

Main Breaker Lug Kits

1
1

Notes
1 Must be purchased in multiples of ordering quantities indicated.
2 Handle ties: typically used to join two similar independent single-pole breakers to form a two-pole noncommon trip breaker.
3 Handle lockoffs: devices that use a padlock to lock the circuit breaker’s handle in the ON or OFF position.
4 See table on Page V1-T1-85 for handle position changeability chart.
5 Escutcheon mounted: device mounted semipermanently to the face of the circuit breaker and secured by the loadcenter deadfront.
6 Handle mounted: device mounted directly to the handle by the use of a set screw.
7 Screw mounted: device permanently mounted to the face of the circuit breaker by the use of a non-removable screw.
8 Hold-down kits: devices used to secure the circuit breaker to the loadcenter for back-feed main application. See NEC Article 384.16(g).

1
1
1
1
1
1
V1-T1-84

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

1.2

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

BRML

Field Installation Kits and Parts, continued
Description

Ordering
Quantity 1

Catalog
Number

10

BRML

10

BRPLOFF

10

BRPLOFF2P

10

BRPLOFF3P

10

BJL2P

10

BJL3P

10

GHQRLOFF2P

10

GHQRLOFF

10

QCD123PLOFF

Mechanical Interlocks
Types BR for two-, three- and four-pole breakers

1
1
1
1
1
1
1
1
1

Shunt Trips, Auxiliary and Alarm Contacts

1

Catalog Number 2
Suffix Adder

Description

1

Shunt Trip for Types BW/CSR

1

12 Volts

SR12

24 Volts

SR24

120 Volts

SR01

1

ST

1

Shunt Trip for Types BR
120 Volts
Auxiliary Contact for Types BW/CSR
1NO and 1NC

AL1

2NO and 2NC

AL2

1
1

Alarm Contacts for Types BW/CSR
CR1

1

Alarm contact for GFCB (single-pole)

W1

1

1NO and 1NC

W2

Types BW/CSR
Alarm Contacts for Type GFCB (Single-Pole)

1
1

Handle Position Changeability Chart

1

To Change Handle Position from ON to OFF, or OFF to ON
You Must...
Handle Lockoff and
Lockdog Types

Remove
Padlock

Remove
Device

Remove
Loadcenter
Deadfront

Lockoff escutcheon mounted

Remove

—

—

Lockoff handle mounted

Remove

Remove

—

Lockoff screw mounted

Remove

—

—

Lockdog escutcheon mounted

N/A

Remove

Remove

Lockdog handle mounted

N/A

Remove

—

1
1
1
1
1

Notes
1 Must be purchased in multiples of ordering quantities indicated.
2 Add suffix indicated to end of breaker catalog number.

1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-85

1.2
1
1
1

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

Wiring Diagrams
Single-Pole 120V Load Application Sourced by 120/240 Vac

Two-Pole Shared Neutral with Duplex Receptacle Application

120/240 Vac
Source
N A B

120/240 Vac
Source
N A B
Line A

1
1

Line B

Line B

1

Two-Pole

Single-Pole
Neutral

120V
Duplex
Receptacle

Neutral

1

Neutral
Neutral

Equipment Ground

120V Duplex
Receptacle
(With Line Side
Jumper Removed)

Equipment Ground

1
1
1
1

Two-Pole Shared Neutral with
Multi-Duplex Receptacle Application

120/240 Vac
Source
N A B

120/240 Vac
Source
N A B

1

1

1
1

Neutral
Neutral

Neutral

Two 120V
Duplex
Receptacles

Neutral

120V
Duplex
Receptacle

Equipment Ground

Equipment Ground

Line A

Two-Pole 240V Load Application Sourced by 120/240 Vac

Single-Pole 120V Duplex Receptacle Application

120/240 Vac
Source
N A B

120/240 Vac
Source
N A B
Line B

1
1
1

Single-Pole

Two-Pole

1
1

Line B

Line B

1
1

Single-Pole 120V Load Application Sourced by 120/240 Vac

Line B

Two-Pole

Single-Pole
Line A

Neutral

1

240V
Duplex
Receptacle

Neutral
Neutral

Equipment Ground

1
1
1
1
1
1
1
V1-T1-86

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

120V
Duplex
Receptacle

Loadcenters and Circuit Breakers
Type BR Loadcenters and Circuit Breakers

1.2

Two-Pole 120V Multi-Duplex Receptacle Application

1

120/240 Vac
Source
N A B

1
1

Line B

1

Two-Pole
Neutral
Neutral

Two 120V
Duplex
Receptacles

1
1
1

Line A

1

Two-Pole 120V Duplex Receptacle Application

1

120/240 Vac
Source
N A B

1

Line B

1

Line A

1

Two-Pole
Neutral
Neutral

120V Duplex
Receptacle
(With Line Side
Jumper Removed)

1
1
1

Two-Pole 240V Duplex Receptacle Application

1

120/240 Vac
Source
N A B

1
1

Line B

1

Two-Pole
Line A
Neutral

1

240V
Duplex
Receptacle

1
1
1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-87

1.3
1

Loadcenters and Circuit Breakers
Loadcenter Interiors/OEM Loadcenters

Contents

OEM Loadcenters

Description

1

Page

Standards and Certifications . . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . .

1

V1-T1-89
V1-T1-89

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Product Description
As a leader in the electrical
distribution equipment
business, Eaton has a
unique product offering for
equipment manufacturers,
panel builders and virtually
any OEM that has a need
for power distribution within
their equipment. The OEM
interior offering consists
of a wide variety of power
distribution options utilizing
components from Eaton’s CH
and BR loadcenter product
lines. With high-volume,
standardized products,
OEMs can expect to
receive high-quality products
covering configurations
meeting virtually any power
distribution need.
Coupled with Eaton’s
expertise in circuit breaker
design and manufacturing,
OEM interiors provide solid
power distribution and circuit
protection in a compact,
easy-to-install package.
Interiors are offered from
2 to 42 circuits and from
70 to 225A.

1
1
1
1

Quality
Built in ISO 9002 certified
manufacturing facilities,
customers can be assured
of the process quality in place
for the manufacture of these
products. Utilizing the latest
in computer-controlled
plating, painting, molding,
stamping and welding
processes, Eaton’s
customers have come to
expect consistent high-quality
from shipment to shipment.

Two Products Offer
Design Flexibility
As a manufacturer of two
lines of loadcenters, Eaton
is in a unique position to
offer the broadest range of
interiors in the market. Each
line has its own unique
characteristics that appeal
to various segments of the
market. OEM interiors are
UL recognized components
and are listed in either of
the following UL files: E8741
or E52977.

The CH interiors feature
100% copper bus and use
the CH 3/4-inch (19.1 mm)
wide circuit breaker, which
minimizes panel space.
Recognized by contractors
for its sturdy design, the
CH interior will appeal to
those customers seeking
an industrial quality bolted
busbar and the space saving
of 3/4-inch (19.1 mm) per
bus stab. With a typical
12 circuit CH interior, this
space savings amounts
to an inch and a half savings
over its 1-inch (25.4 mm)
counterparts. The stab
rating of the CH interiors
is 140A maximum meaning
that the handle rating of
breakers mounted across
from one another may not
exceed 140A.
The BR interiors are
manufactured of formed,
plated aluminum or copper,
and use Eaton’s Type BR
1-inch (25.4 mm) wide circuit
breaker. This design affords
customers the most circuit
flexibility as many of these
interiors allow the installation
of standard single- and
two-pole breakers as well as
duplex (two poles in a 1-inch
(25.4 mm) space) or quadplex
(four poles in a 2-inch
(50.8 mm) space) breakers.

1
V1-T1-88

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

The stab rating of the BR
interiors is 200A maximum,
meaning that the handle
rating of the breakers that
are mounted across from
one another may not
exceed 200A.
The interiors are designed
for either horizontal (singlerow breaker mounting), or
vertical (double-row breaker
mounting). To comply with
National Electrical Code
(NEC) requirements, if
mounted horizontally, when
the breaker is ON, the handle
should be in the UP position.
When mounted vertically, the
handle toggles from left to
right, so this is not a concern.

Loadcenters and Circuit Breakers
Loadcenter Interiors/OEM Loadcenters

1.3

Standards and Certifications
Class CTL

Federal Specifications

National Electrical Code
Paragraph 384-15 requires
branch circuit panelboards
to be provided with physical
means to prevent the
installation of more
overcurrent devices than
that number of which the
enclosure was designed,
rated and approved. Class
CTL Duplex, Quadplex and
twin breakers (identified
by a catalog number prefix
BD, BQ, BQC and CHT)
are equipped with a
UL listed rejection tab
over the line terminal.
All OEM interiors have
appropriately notched stabs
to accept these rejection
tab Class CTL breakers.

All loadcenter enclosures
meet Federal Specifications
W-P-115b, Type 1, Class 2
requirements.

Duplex, Quadplex and twin
breakers manufactured
without the rejection tab
(identified by a catalog
number prefix BR, BRD
and CHNT) are available
for replacement purposes
in older interiors.

All 120/240V breakers, both
1-inch (25.4 mm), 1/2-inch
(12.7 mm) and 3/4-inch
(19.1 mm) per pole meet
the requirement of Federal
Specifications W-C 375B/
Gen Type 1.

Canadian Standards
Association Listing
All single-pole and two-pole,
120/240V breakers, both
1-inch (25.4 mm), 1/2-inch
(12.7 mm) and 3/4-inch
(19.1 mm) per pole, 225A
maximum, are listed as
Certified by the Canadian
Standards Association, Guide
No. 69-11.19, Class 1432,
File 18328.

Underwriters
Laboratories Listing

Lighting and
Appliance Panelboards

All grounding bars
manufactured comply
with Underwriters
Laboratories standards
and are listed under
Guide No. DHJR, File
E31424, Volume W,
Section 17.

Lighting and appliance
branch circuit panelboards are
defined in NEC (Article 384)
as “One having more than
10 percent of its overcurrent
devices rated 30A or less for
which neutral connections
are provided.” Article 384
also limits the number of
overcurrent devices (branch
circuit poles) to a maximum
of 42 in any one cabinet.
When the 42 poles are
exceeded, two or more
separate panels are required.

All circuit breakers 10A
and larger comply with the
Underwriters Laboratories
“Standard for Branch
Circuit and Service CircuitBreakers” UL 489; Guide
No. 60 10.2 File E31424, and
“Requirements for Wire
Connectors and Soldering
Lugs,” UL 486B, Guide
No. 461 10-C File E7830.

For more details and
engineering drawings,
see BR.31.02.S.E.

1
1
1
1
1
1
1
1
1
1
1

All Eaton breakers where
marked, are suitable for use
with 60/75ºC rated wire,
unless otherwise specified.

1
1

All devices comply with the
22 kAIC–10 kAIC UL series
connected components File
DKSY2 of the Recognized
Components Index.

1
1
1

Product Selection

1
1

Type CH Loadcenter Interior Assemblies—Copper Bus
Ampere
Rating

Maximum Number 1-Inch (24.5 mm)
Spaces

Single Poles

UL File
Reference

Main Terminal Size
(Per Phase)

Standard
Package Quantity

Catalog
Number

Single-Phase Single Row Breaker Mounting—120/240 Vac, Three-Wire

1
1

70

2

2

E8741

(1) #8–#2 AWG Cu/Al

1

CH9MB270

125

2

2

E8741

(1) 2/0–#6 AWG Cu/Al

20

CH2L125INT

1
1

Single-Phase Double Row Breaker Mounting—120/240 Vac, Three-Wire
125

4

4

E8741

(1) 2/0–#14 AWG Cu/Al

20

CH4L125INT

125

8

8

E8741

(1) 2/0–#6 AWG Cu/Al

20

CH8L125INT

125

12

12

E8741

(1) 2/0–#6 AWG Cu/Al

20

CH12L125INT

125

16

16

E8741

(1) 2/0–#6 AWG Cu/Al

20

CH16L125INT

200

12

12

E8741

(1) 300 kcmil–#4 AWG Cu/Al

20

CH12L200INT

200

16

16

E8741

(1) 300 kcmil–#4 AWG Cu/Al

10

CH16L200INT

225

24

24

E8741

(1) 300 kcmil–#4 AWG Cu/Al

10

CH24L225INT

225

32

32

E8741

(1) 300 kcmil–#4 AWG Cu/Al

10

CH32L225INT

225

42

42

E8741

(1) 300 kcmil–#4 AWG Cu/Al

10

CH42L225INT

1
1

Three-Phase Double Row Breaker Mounting—208Y/120 Vac, Four-Wire—240 Vac, Three-Wire—120/240 Vac, Four-Wire Delta
125

12

12

E8741

(1) 2/0–#6 AWG Cu/Al

10

CH12L3125INT

125

18

18

E8741

(1) 2/0–#6 AWG Cu/Al

10

CH18L3125INT

125

24

24

E8741

(1) 2/0–#6 AWG Cu/Al

10

CH24L3125INT

225

24

24

E8741

(1) 300 kcmil–#4 AWG Cu/Al

10

CH24L3225INT

225

30

30

E8741

(1) 300 kcmil–#4 AWG Cu/Al

10

CH30L3225INT

225

42

42

E8741

(1) 300 kcmil–#4 AWG Cu/Al

10

CH42L3225INT

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-89

1
1
1

1
1
1

1.3
1

BR Loadcenter
Interior Assembly

1

Loadcenters and Circuit Breakers
Loadcenter Interiors/OEM Loadcenters

Type BR Loadcenter Interior Assemblies—Aluminum Bus
Ampere
Rating

Maximum Number 1-Inch (24.5 mm)
Spaces

Single Poles

UL File
Reference

Main Terminal Size
(Per Phase)

Standard
Package Quantity

Catalog
Number

Single-Phase Single Row Breaker Mounting—120/240 Vac, Three-Wire

1
1
1

70

2

4

E8741

(1) #8–#2 AWG Cu/Al

20

24INT70B

125

2

4

E8741

(1) 1/0–#14 AWG Cu
2/0–12 AWG All

20

24INT125B

125

6

12

E52977

(1) 2/0–#14 AWG Cu/Al

20

612INT125SRB

48INT125B

Single-Phase Double Row Breaker Mounting—120/240 Vac, Three-Wire

1

125

4

8

E8741

(1) 2/0–#14 AWG Cu/Al

20

125

6

12

E8741

(1) 2/0–#14 AWG Cu/Al

20

612INT125B

1

125

8

16

E8741

(1) 2/0–#14 AWG Cu/Al

20

816INT125B

125

12

12

E52977

(1) 2/0–#14 AWG Cu/Al

20

1212INT125B

125

12

24

E52977

(1) 2/0–#14 AWG Cu/Al

20

1224INT125B

1

125

16

24

E52977

(1) 2/0–#14 AWG Cu/Al

20

1624INT125B

125

20

24

E52977

(1) 2/0–#14 AWG Cu/Al

10

2024INT125B

1

125

24

24

E52977

(1) 2/0–#14 AWG Cu/Al

10

2424INT125B

200

8

16

E52977

(1) 300 kcmil–#1 AWG Cu/Al

20

816INT200B

1

200

12

24

E52977

(1) 300 kcmil–#1 AWG Cu/Al

20

1224INT200B

1

200

30

40

E52977

(1) 300 kcmil–#1 AWG Cu/Al

10

3040INT200B

225

42

42

E52977

(1) 300 kcmil–#1 AWG Cu/Al

10

4242INT225B

1

Three-Phase Double Row Breaker Mounting—208Y/120 Vac, Four-Wire—240 Vac, Three-Wire—
120/240 Vac, Four-Wire Delta

1

125

12

24

E52977

(1) 2/0–#8 AWG Cu/Al

10

1224INT3125B

150

18

36

E52977

(1) 300 kcmil–#2 AWG Cu/Al

10

1836INT3150B

1

150

24

42

E52977

(1) 300 kcmil–#2 AWG Cu/Al

10

2442INT3150B

200

30

42

E52977

(1) 300 kcmil–#2 AWG Cu/Al

10

3042INT3200B

1

225

42

42

E52977

(1) 300 kcmil–#2 AWG Cu/Al

10

4242INT3225B

Main Terminal Size
(Per Phase)

Standard
Package Quantity

Catalog
Number

1

1

Type BR Loadcenter Interior Assemblies—Copper Bus

1

Ampere
Rating

1

Maximum Number 1-Inch (24.5 mm)
Spaces

Single Poles

UL File
Reference

Single-Phase Double Row Breaker Mounting—120/240 Vac, Three-Wire

1
1

125

8

16

E5297

(1) 2/0–#14 AWG Cu/Al

20

816INT125BC

125

12

12

E5297

(1) 2/0–#14 AWG Cu/Al

20

1212INT125BC

200

12

24

E5297

(1) 300 kcmil–#1 AWG Cu/Al

20

1224INT200BC

Three-Phase Double Row Breaker Mounting—208Y/120 Vac, Four-Wire—240 Vac, Three-Wire—
120/240 Vac, Four-Wire Delta

1
1

125

12

24

E52977

(1) 2/0–#8 AWG Cu/Al

10

1224INT3125BC

200

12

24

E52977

(1) 300 kcmil–#2 AWG Cu/Al

10

1224INT3200BC

1
1
1
1
1
1
1
V1-T1-90

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

Loadcenters and Circuit Breakers
Loadcenter Interiors/OEM Loadcenters

1.3

Neutral Assemblies
Number of Terminals
Ampere
Rating

UL
File
Rating

Main Incoming Terminal
Wire Size Range
60°C or 75°C

125

E52977

125

1

Dimensions–Inches (mm)

#14–4 AWG
Cu/Al

#6–1/0 AWG Cu
#6–2/0 AWG Al

Standard
Package
Quantity

#6–1/0 AWG Cu
#6–2/0 AWG Al

10

—

E52977

#6–1/0 AWG Cu
#6–2/0 AWG Al

17

125

E52977

#6–1/0 AWG Cu
#6–2/0 AWG Al

225

E52977

225

E52977

125

—

1

Figure

Overall
Length
A

Mounting
B

Catalog
Number

20

1

5.938 (150.83)

5.400 (137.16)

10NEU125B

1

—

20

1

8.388 (213.06)

7.850 (199.40)

17NEU125B

1

20

—

20

1

9.438 (239.73)

8.900 (226.06)

20NEU125B

1

#1–300 kcmil Cu/Al

24

1

20

2

10.913 (277.19)

10.300 (261.62)

24NEU225B

1

#1–300 kcmil Cu/Al

35

1

20

2

15.813 (401.65)

15.200 (386.08)

35NEU225B

—

4

2

1

3

2.266 (57.56)

0.594 (15.09)

BINA

Figure 1

1
1

Figure 2
A

.269
(6.83)

A
.344
(8.74)

B

.844
(21.44)
C
Lof Mounting Hole

B

.269
(6.83)

.844
(21.44)

1.750
(44.45)

C
Lof Mounting Hole

1
1
1
1
1

2.360
(59.94)
2.860
(72.64)

2.360
(59.94)

1

Figure 3
.120
(3.05)

A

.250
(6.35)

.182 Diameter
(4.62)
C
Lof Mounting Hole

1.182
(30.02)
.750
(19.05)

.688
(17.47)

.156
(3.96)

C
L
of
Mounting
Hole

1
1
1

1.750
(44.45)

1.187
(30.15)

B

1

1

.344
(8.74)

1

2.000
(50.80)

1
1
1
1
1
1
1
1
1
1
Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-91

1.3

Loadcenters and Circuit Breakers
Loadcenter Interiors/OEM Loadcenters

1

Add-on Lugs for Neutral Assemblies

1

Description

Wire Size Range
Cu/Al 60°C or 75°C

Ordering
Quantity 1

Catalog
Number

#2/0 maximum

1

NL20

#3/0 maximum

1

NL30

300 kcmil maximum

1

NL300

Length
Inches (mm)

Ordering
Quantity 1

Catalog
Number

dssssds 2.54 (64.5)

1

GBK5 2

dssssdsj 3.59 (91.2)

1

GBK520 2

dssssdssssss 4.29 (109.0)

1

GBK10 2

1

dssssdssssssj 5.34 (135.6)

1

GBK1020 2

1

4.61 (117.1)

1

GBK13 2

dssssdssssssssss 5.69 (144.5)

1

GBK14 2

dssssdssssssssssj 6.74 (171.2)

1

GBK1420 2

Neutral/ground lug
Add-on neutral or ground lug

1
1
1
1

GBK14

Description
(See Legend)

1
BRGBK39512

f
d
f
f
f
k
f
d
f
k
f
f
f

1

Ground Bar Kits

1

1

GBK21 2

1

GBK2120 2

5.78 (146.8)

1

BRGBK39512 34

f
k
f
d
f
k
f
f
f
k
f
d
f
k
f
f
f
k
f

1

dssssdsssssssssssssssss 8.14 (206.8)
dssssdsssssssssssssssssj 9.19 (233.4)

1

Ground Bar Legend

s (3) #14–10 Cu/Al or (1) #14–4 Cu/Al
j (1) #6–2/0 Cu/Al
(1) #14–1/0 Cu/Al or (3) #14–10 Cu/Al
(1) #14–6 Cu/Al or (2) #14–12 Cu/Al
d Mounting Hole

fk

1
1
1

Notes
1 Must be purchased in multiples of ordering quantities indicated.
2 Distance between mounting holes is 1.75 inches (44.5 mm).
3 For single- and three-phase 400 and 600A applications.
4 Distance between mounting holes is 2.34 inches (59.5 mm).

1
1
1
1
1
1
1
1
1
1
1
1
1
1
V1-T1-92

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

Loadcenters and Circuit Breakers
Enclosed Breakers

1.4

Contents

Enclosed Breakers

Description
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . .

Page
V1-T1-94

1
1
1
1
1
1
1
1
1
1

Product Overview

Product Description

Eaton enclosed breakers
offer all the advantages of
circuit breakers packed in an
enclosure for 240 Vac
applications and include a
wide range of accessories.

●

●

●

100–225A, 240 Vac
maximum
NEMA 1 general purpose—
surface or flush mounting
NEMA 3R rainproof
surface mounting

1

Standards and
Certifications
●
●
●

1

UL 489
CSA 22.2
NEMA 250

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-93

1.4

Loadcenters and Circuit Breakers
Enclosed Breakers

1

Product Selection

1

Single-Phase Circuit Breaker Enclosures—10/25/35 kAIC

1
1

Circuit Breaker
Unit Enclosures

Type ECB Circuit Breaker Enclosure—Includes Lug Kit
Main Ampere
Rating

Type of
Circuit Breaker

Wire Size Range
Cu/Al 60°C or 75°C

Catalog
Number

—

CSR (included) 1

4

ECB150RB 567

—

2

4

ECB200RB 567

CSH

4

ECB225F 367

CSR

3

4

ECB225S 367

CSR

3

4

ECB225R 3567

Mounting

Single-Phase Three-Wire—240 Vac Maximum

1

150

1

Outdoor

200

Outdoor

225

Indoor

1

Flush

Indoor

Surface

Outdoor

1
1

Unit Enclosure
Type

CSR2200N

1

Circuit Breakers 120/240 Vac—25 kAIC
For Use in Type ECB Enclosures
Ampere
Rating

1

—

Two-Pole Breakers
Catalog Number

Wire Size Range
Cu/Al 60°C or 75°C
for Line Terminals

10 kAIC

25 kAIC

100

#2–300 kcmil

—

CSR2100N

125

#2–300 kcmil

BW2125

CSR2125N

1

150

#2–300 kcmil

BW2150

CSR2150N

175

#2–300 kcmil

BW2175

CSR2175N

1

200

#2–300 kcmil

BW2200

CSR2200N

225

#2–300 kcmil

BW2225

CSR2225N

1

1

CSR (included)
BW, CSR

3,

Wire Data
Wire/Application

Maximum
Wire Size

Maximum
Ampere Rating

Aluminum—standard

250 kcmil

200

Aluminum—service entrance

250 kcmil

225

Copper—standard and service entrance

250 kcmil

225

Shunt Trips, Auxiliary and Alarm Contacts
Description

Catalog Number
Suffix Adder 8

Shunt Trip for Types BW/CSR

1

Shunt Trips
Catalog Number
Suffix Adder 8

1

Type

1

CSR

12

SR12

CSR

24

SR24

CSR

120

SR01

Volts

12V

SR12

24V

SR24

120V

SR01

Auxiliary Contact for Types BW/CSR

1

1NO and 1NC

AL1

2NO and 2NC

AL2

Alarm Contacts for Types BW/CSR
Types BW/CSR

1

Lug Kit for Replacement Purposes Only
For Use in Type ECB Enclosures

1

Ampere
Rating

1

225

1
1
1
1
1

Description
For use on 125,
150, 175, 200 and
225A breakers

Wire Size Range
Cu/Al 60°C or 75°C Catalog
for Line Terminals Number
#2–300 kcmil

MCBK225

Alarm Contacts for Type GFCB (Single-Pole)
Alarm contact for GFCB (single-pole)

W1

1NO and 1NC

W2

Notes
1 CSR2150N factory-installed circuit breaker.
2 CSR2200N factory-installed circuit breaker.
3 Order circuit breaker separately.
4 Wire size is determined by the circuit breaker installed in enclosure.
Maximum wire size and ampere rating is determined by Wire Data table above.
5 Rainproof panels are furnished with hub closures plates. For rainproof hubs,
refer to Page V1-T1-25.
6 One ground lug accepting (1) #14 –#2 is factory installed. Also, there are pre-drilled
holes to accept a GBK5 ground bar.
7 Approved for service entrance.
8 Add suffix indicated to end of breaker catalog number.
Box sizes Pages V1-T1-27 and V1-T1-28.

1
1
1
V1-T1-94

CR1

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

1.4

Loadcenters and Circuit Breakers
Enclosed Breakers

Single-Phase and Three-Phase Circuit Breaker Enclosures—10/25 kAIC

ECC225S

1
1

Type ECC Circuit Breaker Enclosure—Order Type CC Circuit Breaker Separately
Main Ampere
Rating

Unit Enclosure
Type

Mounting
Type

Circuit
Breaker Type

Wire Size Range
Cu/Al 60°C or 75°C

Catalog
Number

1

Single- and Three-Phase—240 Vac Maximum

1

225

Indoor

Flush

CC/CCV/CCH

5

ECC225F 123

225

Indoor

Surface

CC/CCV/CCH

5

ECC225S 123

CC/CCV/CCH

5

ECC225R 1234

225

Outdoor

—

1
1
1

CCV2200

Circuit Breaker 240 Vac for Use in
Type ECC Enclosures

Ampere
Rating

Wire Size
Range
Cu/Al 60°C
or 75°C
for Line
Terminals

Type CCV and
CC 10 kAIC
Catalog
Number

Type
CCVH/CCH
25 kAIC
Catalog
Number 8

Two-Pole
100

#4–4/0

CCV2100

CCVH2100

125

CCV2125

CCVH2125

150

CCV2150

CCVH2150

175

#2/0–300 kcmil CCV2175

CCVH2175

200

CCV2200

CCVH2200

225

CCV2225

CCVH2225

Three-Pole
100

CC3100

CCH3100

125

#4–4/0

CC3125

CCH3125

150

CC3150

CCH3150

175

#2/0–300 kcmil CC3175

CCH3175

200

CC3200

CCH3200

225

CC3225

CCH3225

1

Wire/Application Chart
Wire/Application

Maximum
Wire Size

Maximum
Ampere Rating

1

Aluminum—standard

250 kcmil

200

Aluminum—service entrance

250 kcmil

225

1

Copper—standard and service entrance

250 kcmil

225

Notes
1 Order circuit breaker separately.
2 One ground lug accepting (1) #14–#2 is factory installed. Also, there are pre-drilled holes to
accept a GBK5 ground bar.
3 Approved for service entrance.
4 Rainproof panels are furnished with hub closures plates. For rainproof hubs, refer to
Page V1-T1-65.
5 Wire size is determined by the circuit breaker installed in enclosure. Maximum wire size and
ampere rating is determined by the Wire/Application Chart.
6 CCV breakers are two-pole only.
7 Add suffix indicated to end of breaker catalog number.
8 Series ratings are not available for CCH or CCVH breakers.
Box sizes Pages V1-T1-66 through V1-T1-68.

1
1
1
1
1
1
1
1
1

Shunt Trips and Auxiliary Contacts 6
Description

1

Volts

Catalog Number
Suffix Adder 7

1

CC

12 DC

SR12

1

CC

24 DC

SR24

CC

120 AC

SR01

CC

208 AC

SR08

CC

240 AC

SR02

CCV

48–127 AC/48–60 DC

SR01

CCV

9–24 AC/12–24 DC

SR24

Type
Shunt Trip

1
1
1
1

Auxiliary Contact
CC 1NO and 1NC —

1

AL1

1
1
1
Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-95

1.5
1

Loadcenters and Circuit Breakers
Classified Circuit Breakers

Contents

Classified Breakers

Description

1

Page

Product Selection . . . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . .

1
1

V1-T1-97
V1-T1-99
V1-T1-99
V1-T1-100

1
1
1
1
1
1
1
1
1
1
1
1
1

Product Description
Eaton UL classified
Replacement Circuit Breakers
are available in both 3/4-inch
Type CHQ and 1-inch Type
CL, single- and two-pole
configurations. These
breakers are classified as
direct replacements by
Underwriters Laboratories.
In addition to a UL listing,
they also come with a
15-year warranty.

1
1

Specified vs. UL Classified

Testing

Specified breakers are listed
by the manufacturer of the
panelboard for use in a
particular panel. This doesn’t
mean that the panelboard
manufacturer produced the
specified breaker; it merely
means that the panelboard
manufacturer has tested the
breaker in the panel. In fact,
through the years, Eaton has
manufactured thousands of
breakers for other panelboard
manufacturers.

Classified breakers are
tested extensively in
numerous General Electric®,
Siemens®, Murray®,
Thomas & Betts®, Square D®,
and Crouse-Hinds® panels.
The tests are conducted with
witnesses from Underwriters
Laboratories Inc. and involve
short-circuit, temperature,
and insertion/withdrawal
applications. This level of
testing ensures that the
breakers meet identified
standards and have been
found suitable by UL for
the specified purpose.

UL classified breakers
are produced by one
manufacturer for use in
place of the breakers
specified on the panelboard.
Like specified breakers,
UL classified breakers have
been tested in the panels for
which they are approved.

1
1
1
1

Understanding Classified
Breaker Terminology
Definitions
Specified circuit breaker—
each manufacturer lists
the brands of circuit
breakers that can be used
in their panelboards. Often,
manufacturers will not list
competitors as specified,
even though they are
suitable replacements.
Classified circuit breaker—
a breaker that is considered
suitable, by a qualified thirdparty organization, for use
in another manufacturer’s
panelboard.
Listed breaker—the listing
of a circuit breaker is by an
independent third party. Eaton
classified breakers are listed
by UL.
Labeled breaker—a breaker
with a label affixed by an
independent third party.

1
1
1
1
1
1
1
V1-T1-96

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

Loadcenters and Circuit Breakers
Classified Circuit Breakers

1.5

Product Selection

1

Type CHQ Replacement Breakers for Square D Type QO Loadcenters

1

10 kAIC, 120 and 120/240 Vac
CHQ120 CHQ230

1

Type CHQ Classified Breakers 3/4-Inch (19.1 mm) per Pole
120 or 120/240 Vac, 10 kAIC

Single-Pole 120/240 Vac
Requires One
3/4-Inch (19.1 mm) Space
10 per Shelf Carton

Two-Pole 120/240 Vac
Common Trip Requires Two
3/4-Inch (19.1 mm) Spaces
5 per Shelf Carton

Catalog Number

Catalog Number

CHQ115

CHQ215

CHQ120

CHQ220

25

CHQ125

CHQ225

30

CHQ130

CHQ230

35

CHQ135

CHQ235

40

CHQ140

CHQ240

45

CHQ145

CHQ245

50

CHQ150

CHQ250

60

—

CHQ260

Ampere
Rating

Wire Size Range
Cu/Al 60ºC or 75°C

15

(1) #14–8
(2) #14–10

20

1
1
1
1
1
1
1
1
1
1

Type CHQ Ground Fault and Arc Fault Replacement Breakers for Square D Type QO Loadcenters

1

10 kAIC, 120 and 120/240 Vac
CHQ115GF CHQ220GF

1

Type CHQ Ground Fault Breakers—5 Milliampere—
3/4-Inch (19.1 mm) per Pole, 10 kAIC

Single-Pole 120 Vac
Requires One
3/4-Inch (19.1 mm) Space
10 per Shelf Carton

Two-Pole 120/240 Vac
Common Trip Requires Two
3/4-Inch (19.1 mm) Spaces
5 per Shelf Carton

Catalog Number

Catalog Number

CHQ115GF

CHQ215GF

CHQ120GF

CHQ220GF

25

CHQ125GF

CHQ225GF

30

CHQ130GF

CHQ230GF

35

—

CHQ235GF

40

—

CHQ240GF

45

—

CHQ245GF

50

—

CHQ250GF

Ampere
Rating

Wire Size Range
Cu/Al 60ºC or 75°C

15

(1) #14–8
(2) #14–10

20

1
1
1
1
1
1
1
1
1
1

Type CHQ Surge Arrester

1

Catalog Number
CHQSA

1
1
1
1
Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-97

1.5
1

Loadcenters and Circuit Breakers
Classified Circuit Breakers

Type CL Replacement Breakers for Square D HOMELINE, General Electric, Crouse-Hinds,
Thomas & Betts, Murray and ITE®/Siemens Loadcenters

1
1

CL_

Type CL Breakers, 1-Inch (25.4 mm) per Pole, 10 kAIC

1
Ampere
Rating

Wire Size
Range Cu/Al
60°C or 75°C

Single-Pole 120/240V
Requires One
1-Inch (25.4 mm) Space
10 per Shelf Carton
Catalog Number

15

#14–4

CL115

CL215

1

20

#14–4

CL120

CL220

25

#14–4

CL125

CL225

1

30

#14–4

CL130

CL230

1

35

#14–4

CL135

CL235

40

#14–4

CL140

CL240

45

#14–4

CL145

CL245

50

#14–4

CL150

CL250

1
1

1

Two-Pole 120/240V
Common Trip Requires Two
1-Inch (25.4 mm) Spaces
5 per Shelf Carton
Catalog Number

1
1

CL_AF

Type CL Classified Arc and Ground Fault Breakers (5 Milliampere),
1-Inch (25.4 mm) per Pole, 10 kAIC

1
1

Ampere
Rating

1

Wire Size
Range Cu/Al
60°C or 75°C

Single-Pole 120/240V
Requires One 1-Inch (25.4 mm) Space
1 per Shelf Carton
Catalog Number

Arc Fault Breakers

1

15

#14–4

CL115AF

1

20

#14–4

CL115CAF

20

#14–4

CL120AF

1

20

#14–4

CL120CAF

Ground Fault Breakers

1
1

15

#14–4

CL115GF

20

#14–4

CL120GF

30

#14–4

CL130GF

1
1

CLR_

Type CL Classified Latching Remote Control Smart Breakers™,
1-Inch (25.4 mm) per Pole, 10 kAIC

1
1
1
1
1

Ampere
Rating

Wire Size
Range Cu/Al
60°C or 75°C

Single-Pole 120V
Requires One
1-Inch (25.4 mm) Space
10 per Shelf Carton
Catalog Number

15

(2) #14–10

CLRP115

CLRP215

20

(2) #14–10

CLRP120

CLRP220

25

(1) #8–6

CLRP125

CLRP225

30

(1) #8–6

CLRP130

CLRP230

Two-Pole 120/240V
Common Trip Requires Two
1-Inch (25.4 mm) Spaces
5 per Shelf Carton
Catalog Number

1
1
1
V1-T1-98

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

Loadcenters and Circuit Breakers
Classified Circuit Breakers

Accessories

1.5

Technical Data

CHQ Breaker Accessories
Description

Catalog
Number

Breaker handle lock

CHLO

Arc Fault Application Notes
An arc fault circuit interrupter
is a device intended to
provide protection from
the effects of arc faults by
recognizing characteristics
unique to arcing and by
functioning to de-energize
the circuit when the arc
fault is detected. As of
January 1, 2002, the
National Electrical Code
(NEC) requires all branch
circuits that supply 125V,
single-phase, 15 and 20A
receptacle outlets installed
in dwelling unit bedrooms
shall be protected by an arc
fault circuit interrupter(s).
This includes ceiling lighting
(recessed, ceiling fans, etc.)
as well as smoke detectors
and all other bedroom outlets.
The 2005 NEC introduced the
application of the
Combination Type AFCI for
bedroom circuits required as
of January 1, 2008. The 2008
NEC expands this application
to other living areas.

1

Ground Fault
Application Notes

1

Single-pole GFCBs are
designed for use in two-wire,
120 Vac circuits. Drawing
on Page V1-T1-100 shows a
typical wiring configuration.

1
1
1

Two-pole GFCBs are
designed for use in threewire, 120/240 Vac circuits,
120 Vac multiwire circuits
employing common, neutral
and two-wire, 240 Vac
circuits obtained from a
120/240 Vac source.

1
1
1
1

Drawings on Page V1-T1-100
illustrate typical wiring
configurations for
120/240 Vac multiwire
circuits.

1
1

Drawing on Page V1-T1-100
depicts a 240 Vac, two-wire
circuit. Note the “panel
neutral” conductor connects
to the neutral bar, even
though the neutral is not
included in the load circuit.
This connection is necessary
to supply a 120 Vac power
source to the ground fault
sensing circuit.

1
1
1
1
1

The figures are shown with
a 120/240 Vac, single-phase,
three-wire power source,
ut are also applicable to a
120/208 Vac, three-phase,
four-wire power supply.
For all figures, the electrical
operation of the GFCB
is not affected by the
equipment ground.

1
1
1
1
1
1
1
1
1
1
1
1
1
1

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

V1-T1-99

1.5
1
1
1

Loadcenters and Circuit Breakers
Classified Circuit Breakers

Wiring Diagrams
Single-Pole 120V Load Application Sourced by 120/240 Vac

Two-Pole 240V Load Application Sourced by 120/240 Vac

120/240 Vac
Source
N A B

120/240 Vac
Source
N A B

1
1

1
1
1

Neutral
Neutral

1
1
1

Neutral

Equipment Ground

Two-Pole Shared Neutral with
Duplex Receptacle Application

120/240 Vac
Source
N A B

120/240 Vac
Source
N A B
Line B

Line B
Line A

Two-Pole

Two-Pole
Neutral
Neutral

Two 120V
Duplex
Receptacles

Neutral
Neutral

120V Duplex
Receptacle
(With Line Side
Jumper Removed)

Equipment Ground
Equipment Ground

Line A

Single-Pole 120V Duplex Receptacle Application

Two-Pole 120V Duplex Receptacle Application

120/240 Vac
Source
N A B

120/240 Vac
Source
N A B

1

Line B

Line B

1
1

240V
Duplex
Receptacle

Line A

Two-Pole Shared Neutral with
Multi-Duplex Receptacle Application

1
1

120V
Duplex
Receptacle

Equipment Ground

1
1

Two-Pole

Single-Pole

1
1

Line B

Line B

1

Line A

Two-Pole

Single-Pole
Neutral
Neutral

120V
Duplex
Receptacle

Neutral
Neutral

1

120V Duplex
Receptacle
(With Line Side
Jumper Removed)

1
1
1

Two-Pole 120V Multi-Duplex Receptacle Application

Two-Pole 240V Duplex Receptacle Application

120/240 Vac
Source
N A B

120/240 Vac
Source
N A B

1
1
1

Line B

Line B

Two-Pole

Two-Pole
Neutral
Neutral

1
1

Two 120V
Duplex
Receptacles

Line A
Neutral

Line A

V1-T1-100

Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com

240V
Duplex
Receptacle

Surge Protection
Surge Protection Devices

2.1

Surge Protection Devices and Lightning Arresters
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Application Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Standards and Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

V1-T2-2
V1-T2-2
V1-T2-3
V1-T2-4

2
2
2
2

Learn
Online

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com

V1-T2-1

2.1
2

Surge Protection
Surge Protection Devices and Lightning Arresters

Contents

Surge Protection Devices

Description

2

Page

Surge Protection Devices and Lightning Arresters
Standards and Certifications . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . .

2

V1-T2-3
V1-T2-4

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Product Description

Application Description

Due to the evolution
of electronics and
microprocessors in the
home, there is a continuous
challenge to provide quality
(clean) power for electronic
loads such as appliances,
computers/home office and
entertainment systems.
Surges caused by lightning,
utility grid switching and
other sources travel on
current carrying conductors
throughout the home, which
can effect and destroy
sensitive electronic loads.

Two-Stage Protection

Eaton offers a comprehensive
family of surge products for
use at service entrance.
These products can help
protect sensitive electronics
against the damaging effects
of surges.

2
2

Service Entrance Surge
Protection
Eaton’s service entrance
surge protection units
provide premier surge
protection for AC power
at the service entrance.
These products provide
protection for residential
electrical equipment by
reducing power surges
to an acceptable level for
surge strips to handle at
the point of use.
UL 1449 3rd Edition Type 1 and
Type 2 Surge Protection
●
Type 1 Surge Protective
Device (SPD)—
Permanently connected
Type 1 SPDs are intended
for installation between the
secondary of the service
transformer and the line
side of the service
equipment overcurrent
device, as well as the load
side, including watt-hour
meter socket enclosures
and are intended to be

2
2
2
2
2
2
V1-T2-2

installed without an
external overcurrent
protective device.
Type 1 devices are
dual-rated for Type 2
applications as well,
providing the highest
ratings available for
installation at the service
entrance
●
Eaton’s CHSPT1
products provide Type 1
surge protection in
accordance with UL®
1449 3rd Edition. These
units can be universally
mounted outside any
manufacturer’s primary
service equipment

Two stages of surge
suppression are
recommended to provide
the best protection for
electronic equipment.
Two-stage surge suppression
should be provided for all
cables entering a home,
including power, Internet,
coaxial and telephone.

●

Type 2 Surge Protective
Device—Permanently
connected Type 2 SPDs
are intended for installation
on the load side of the
service equipment
overcurrent device,
including SPDs located at
the branch panel
●
CHSPT2 products provide
Type 2 surge protection in
accordance with UL 1449
3rd Edition. These units
can be mounted outside
of any manufacturer’s
loadcenter or inside an
Eaton Surge/Surge Ready
loadcenter. Eaton also
offers accessories to the
CHSPT2 line for
telephone and cable
protection.

Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com

●

Factory-Installed Surge
Protection—Eaton’s
loadcenters with factoryinstalled surge protection
include a CHSPT2ULTRA
and a two-pole 50A circuit
breaker. These loadcenters
increase the effectiveness
of surge protection due
to reduced lead length.
A modified deadfront
allows for easy viewing
of indicating lights for
status indication

Surge Panel
●

Surge Ready
Loadcenter—The SurgeReady loadcenter provides
a mounting provision for
the CHSPT2ULTRA. This
loadcenter has a modified
deadfront to allow for
viewing of indicating lights.

Surge Protection
Surge Protection Devices and Lightning Arresters

2.1

Two-Stage Protection
●

1
2

CHSP installed at the service entrance panel.
SurgeTrap™ surge traps and strips located where sensitive electronics are plugged in.

Plug-On Surge Protection
●
Type CHSA—For use on
single-phase 120/240 Vac
systems. The CHSA easily
plugs into a single-phase
Type CH loadcenter and
occupies two 3/4-inch
(19.1 mm) pole spaces,
similar to a two-pole Type
CH breaker. When installed
properly, it provides surge
protection for the entire
loadcenter. If internal
components are damaged,
the CHSA LED visual
indicators will signal the
need for a replacement.
This device is suitable for
service entry locations
when installed in
accordance with NEC®
guidelines.

●

Type BRSURGE—For use
on single-phase 120/240
Vac systems. This easily
plugs into a single-phase
Type BR loadcenter and
occupies two 1-inch (25.4
mm) pole spaces similar to
a two-pole Type BR
breaker. When installed
properly, it provides surge
protection for the entire
loadcenter. If internal
components are damaged,
the BRSURGE LED visual
indicators will signal the
need for replacement.
This device is suitable
for service entry locations
when installed in
accordance with NEC
guidelines. This unit is
also classified by UL for
use in select GE, ITE/
Siemens, and CrouseHinds Panels. (Refer to
Pub No. 5655B65H01 for
additional details.)

●

Type CHQSA—For use
on single-phase, 120/240 Vac
systems. This unit easily
plugs into a Square D
single-phase loadcenter
Type QO® and occupies
two 3/4-inch (19.1 mm)
pole spaces similar to a
two-pole Type QO breaker.
When installed properly, it
provides surge protection
for the entire loadcenter. If
internal components are
damaged, the CHQSA LED
visual indicators will signal
the need for a replacement.
This device is suitable for
service entrance locations
installed in accordance
with NEC guidelines. This
device is UL classified to
be used in place of Square D
Type QO surge arresters
(refer to Pub-23974).
Type BRSURGECSA—
For use on single-phase
120/240 Vac systems. This
easily plugs into a singlephase Type BR loadcenter
and occupies two 1-inch
(25.4 mm) pole spaces
similar to a two-pole Type
BR breaker. When installed
properly, it provides surge
protection for the entire
loadcenter. If internal
components are damaged,
the BRSURGECSA LED
visual indicators will signal
the need for replacement.
This device is suitable
for service entry locations
when installed in
accordance with Canadian
Electrical Code. This device
is CSA® listed to be used in
a Type BR loadcenter.

Type 3 Point-of-Use Surge
Protection
Point-of-use surge strips are
designed to offer premium
surge protection for specific
electronics while providing
innovative features to
enhance user convenience.

Standards and
Certifications
●

●

●
●
●

●

2
2
2
2
2
2

CHSPT1 Products: UL
1449 3rd Edition Type 1
CHSPT2 Products:
UL/cUL® 1449 3rd Edition
Type 2
CHSPTELE: UL 497A, cUL
CHSPCABLE: UL 6500, cUL
NEMA® 3R Enclosure for
CHSPTELE and
CHSPCABLE: UL 50
Enclosure
BRSURGE, CHSA,
BRSURGECSA, CHQSA:
UL 1449 3rd Edition plug-in
type; Type 2 SPD

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com

V1-T2-3

2.1
2

Surge Protection Devices and Lightning Arresters

Product Selection

2

SPD Type 1 CHSP Service Entrance Surge Protection—UL 1449 3rd Edition

2

Product Features
●
Commercial grade AC power protection
●
Type 1 surge device for installation before or after the main service disconnect
●
Convenient mounting options—universal fit to any manufacturer’s equipment
●
Clear, visible LED indication displaying status of the surge protector

2
2
2
2

Surge Protection

Catalog
Number

Connection

Enclosure Voltage

Frequency
Phase (Hz)
MCOV 1

VPR

2

In

3

SCCR

4

Surge Current
Capacity, Per
Phase Rating 5

CHSPT1ULTRA

CHSPT1ULTRA

Permanently connected device
NEMA 4
installed before or after the service
disconnect overcurrent device.

100/200,
110/220,
120/240

Single

50/60

L-L 300,
L-N 150

L-L 1000, 20 kA 200 kA
L-N 600

50 kA

CHSPT1MAX

CHSPT1MAX

Permanently connected device
NEMA 4
installed before or after the service
disconnect overcurrent device.

100/200,
110/220,
120/240

Single

50/60

L-L 300,
L-N 150

L-L 1000, 20 kA 200 kA
L-N 600

45 kA

CHSPT1MICRO

CHSPT1MICRO

Permanently connected device
NEMA 4
installed before or after the service
disconnect overcurrent device.

100/200,
110/220,
120/240

Single

50/60

L-L 300,
L-N 150

L-L 1000, 20 kA 200 kA
L-N 600

36 kA

CHSPT1-208Y

CHSPT1-208Y

Permanently connected device
NEMA 4
installed before or after the service
disconnect overcurrent device.

120/208

Threephase
wye

50/60

L-L 300,
L-N 150

L-L 1000, 20 kA 200 kA
L-N 600

50 kA

2
2
2
2
2
2
2
2
2
2
2
2
2

Accessory for Type 1 CHSP Service Entrance Surge Protection

2
2

SP1DINRAILKIT

Catalog
Number

Description

SP1DINRAILKIT

Mounting kit for wall or DIN rail installation.

2
2
2
Notes
1 MCOV: Maximum Continuous Operating Voltage that may be applied to the device per mode.
2 VPR: Voltage Protection Rating is the measured limiting voltage after a surge event.
3 I : Nominal Discharge Current is the current that the device can withstand for 15 impulses.
n
4 SCCR: The amount of current the product can withstand under short-circuit conditions.
5 Surge Current Capacity: The maximum one time surge current rating per phase.

2
2
2

For warranty details, go to www.eaton.com/surgetrap.

2
2
V1-T2-4

Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com

2.1

Surge Protection
Surge Protection Devices and Lightning Arresters

SPD Type 2 CHSP Service Entrance Surge Protection—UL 1449 3rd Edition; cUL

2

Product Features
●
AC power protection
●
Universally connects to any manufacturer’s loadcenter (breaker box)
●
Quick connect design—easy to mount telephone and cable protection modules
●
LED status indication
Catalog
Number
CHSPT2ULTRA

CHSPT2MAX

CHSPT2MICRO

CHSPT2ULTRA

CHSPT2MAX

CHSPT2MICRO

Connection

Enclosure Voltage

Can be attached to the outside of
any manufacturer’s loadcenter
(breaker box). This product should
be connected on the load side of
the loadcenter main service
disconnect through a dedicated
circuit breaker (follow NEC
Guidelines).

NEMA 4

Can be attached to the outside of
any manufacturer’s loadcenter
(breaker box). This product should
be connected on the load side of
the loadcenter main service
disconnect through a dedicated
circuit breaker (follow NEC
Guidelines).

NEMA 4

Can be attached to the outside of
any manufacturer’s loadcenter
(breaker box). This product should
be connected on the load side of
the loadcenter main service
disconnect through a dedicated
circuit breaker (follow NEC
Guidelines).

NEMA 4

Frequency
Phase (Hz)
MCOV 1 VPR 2

120/240
Single
Vac rated
line voltage

60

2
2
In 3

150V L-N, 600V L-N, 20 kA
300V L-L 1000V L-L,
800V N-G,
600V L-G

SCCR 4
6

22 kA

Surge Current
Capacity, Per
Phase Rating 5
108 kA
(L1-N 54 kA, L1-G
54 kA, L2-N 54
kA, L2-G 54 kA)

2
2
2
2
2

120/240
Single
Vac rated
line voltage

60

150V L-N, 600V L-N, 10 kA
300V L-L 1000V L-L,
800V N-G,
600V L-G

22 kA

72 kA
(L1-N 36 kA, L1-G
36 kA, L2-N 36
kA, L2-G 36 kA)

2
2
2

120/240
Single
Vac rated
line voltage

60

150V L-N, 600V L-N, 5 kA
300V L-L 1000V L-L,
800V N-G,
600V L-G

22 kA

36 kA
(L1-N 18 kA, L1-G
18 kA, L2-N 18
kA, L2-G 18 kA)

2
2
2
2

Notes
1 MCOV: Maximum Continuous Operating Voltage that may be applied to the device per mode.
2 VPR: Voltage Protection Rating is the measured limiting voltage after a surge event.
3 I : Nominal Discharge Current is the current that the device can withstand for 15 impulses.
n
4 SCCR: The amount of current the product can withstand under short-circuit conditions.
5 Surge Current Capacity: The maximum one time surge current rating per phase.
6 When used with a 50A two-pole circuit breaker, 10 kA when used with a 15A two-pole circuit breaker.

2
2
2

For warranty details, go to www.eaton.com/surgetrap.

2
2
2
2
2
2
2
2
2
2
2
2
Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com

V1-T2-5

2.1

Surge Protection Devices and Lightning Arresters

Accessories for CHSP Type 2 Service Entrance Protection

2

Catalog
Number

2
2

Surge Protection

Description

Installation

Surge Current
Capacity

DC
Breakdown
Voltage

CHSPCABLE

CHSPCABLE

Quick Connect design—add additional
telephone and AC protection modules;
protects two quad shield cables;
bi-directional

Indoor installation; or rain-tight when
used with recommended enclosure

10 kA per line

145V

CHSPTELE

CHSPTELE

Quick Connect design—add additional AC
and cable protection modules; protects four
telephone lines

Indoor installation; or rain-tight when
used with recommended enclosure

20 kA per line

230V

CHSPT23PACK

CHSPT23PACK

3-Pack:
CHSPT2ULTRA+CHSPTELE+CHSPCABLE;
Surge protection for AC power,
telephone and cable—see individual product
features

CHSP3RTELCABLE

CHSP3RTELCABLE

Raintight enclosure for CHSPTELE and
CHSPCABLE; top or bottom feed; enclosure
only, surge not included; accommodates up to
two devices

CHSPFMKIT

CHSPFMKIT

Flushmount kit for: CHSPT2ULTRA,
CHSPT2MAX, CHSPT2MICRO, CHSPTELE,
CHSPCABLE

MSEGR2

MSEGR2

Outdoor communication grounding device;
meets 2008 NEC requirements for
intersystem bonding termination

2

Voltage

2
2
2
2
2
2
2
2

See individual
product ratings

2
2
2
2
2
2
2
2
2

Note
For warranty details, go to www.eaton.com/surgetrap.

2
2
2
2
2
2
2
2
2
V1-T2-6

Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com

Ring 90–120 Vac/
Tone 48–52 Vdc

Surge Protection
Surge Protection Devices and Lightning Arresters

Factory-Installed Surge Protection
●
Includes a CHSPT2ULTRA
and a two-pole 50A circuit
breaker
●
Increases the
effectiveness of surge
protection due to reduced
lead length

●

2.1
2

A modified deadfront
allows for easy viewing
of indicating lights for
status indication

2
2
2
2

Surge Installed

Surge Installed Loadcenters

2

Cover Catalog Number
Catalog Number

Description

CHSUR42N225L 1

42 ckt, 225A, convertible

Surface

CHSUR8LF

CHSUR8LS

2

CHSUR8LF

CHSUR8LS

CHSUR42B200L2 1

42 ckt, 200A, main breaker

CHSUR8LF

CHSUR8LS

CHSUR32N225K 1

32 ckt, 225A, convertible

CHSUR8KF

CHSUR8KS

CHSUR32L225K 1

32 ckt, 225A, convertible 2

CHSUR8KF

CHSUR8KS

CHSUR42L225L2

1

Combination

42 ckt, 225A, convertible

CHSUR32B200K 1

32 ckt, 200A, main breaker

CHSUR8KF

CHSUR8KS

CHSUR32B150K 1

32 ckt, 150A, main breaker

CHSUR8KF

CHSUR8KS

CHSUR32B100K 1

32 ckt, 100A, main breaker

CHSUR8KF

CHSUR8KS

CHSUR24L125E 1

24 ckt, 125A, convertible 2

CHSUR8EF

CHSUR8ES

1

24 ckt, 100A, main breaker

CHSUR8EF

CHSUR8ES

BRSUR4040N200

40/40 ckt, 200A, convertible

Cover included

BRSUR4040L200

40/40 ckt, 200A, main lug

Cover included

BRSUR4040B200

40/40 ckt, 200A, main breaker

Cover included

BRSUR3040N200

30/40 ckt, 200A, convertible

Cover included

BRSUR3040L200

30/40 ckt, 200A, main lug

Cover included

BRSUR3040B200

30/40 ckt, 200A, main breaker

Cover included

CHSUR24B100E

2
2
2
2
2
2
2
2
2
2

Surge Ready Loadcenters
●
Provides a mounting
provision for
CHSPT2ULTRA
●
A modified deadfront
allows for easy viewing of
indicating lights

Surge Ready

2
2
2
2
2

Surge Ready Loadcenters (Provision Only, CHSPT2ULTRA and Breaker Not Included)
Cover Catalog Number
Catalog Number

Description

Combination

Surface

CHEC42N225L 1

42 ckt, 225A, convertible

CHSUR8LF

CHSUR8LS

CHEC42L225L 1

42 ckt, 225A, convertible 2

CHSUR8LF

CHSUR8LS

CHEC42B200L 1

42 ckt, 200A, main breaker

CHSUR8LF

CHSUR8LS

CHEC32L225K 1

32 ckt, 225A, convertible 2

CHSUR8KF

CHSUR8KS

CHEC32N225K 1

32 ckt, 225A, convertible

CHSUR8KF

CHSUR8KS

CHEC32B200K 1

32 ckt, 200A, main breaker

CHSUR8KF

CHSUR8KS

CHEC32B150K 1

32 ckt, 150A, main breaker

CHSUR8KF

CHSUR8KS

CHEC32B100K 1

32 ckt, 100A, main breaker

CHSUR8KF

CHSUR8KS

CHEC24L125E 1

24 ckt, 125A, convertible 2

CHSUR8EF

CHSUR8ES

CHEC24B100E 1

24 ckt, 100A, main breaker

CHSUR8EF

CHSUR8ES

2
2
2
2
2
2
2

Notes
1 Order cover separately.
2 With main lugs installed.

Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com

2
2
V1-T2-7

2.1

Surge Protection Devices and Lightning Arresters

SPD Type 2 Plug-On Surge Protection—UL 1449 3rd Edition

2

Product Features
●
Convenient surge protection for the loadcenter

2
2
2

Surge Protection

Catalog
Number

Frequency
Voltage Phase (Hz)
MCOV 1 VPR 2

In

3

SCCR

4

Surge Current
Capacity, Per
Phase Rating 5

Description

Connection

BRSURGE

BRSURGE

UL for use in a single-phase Type BR
loadcenter. This unit is classified by UL
for use in select GE, ITE/Siemens and
Crouse-Hinds panels (refer to Pub. No.
5655B65H01 for additional details).

Plug on to the
120/240 Single
loadcenter bus;
see instructions.

60

L1-N 150V, L1-N 600V, 3k
L-L 300V L-L 1000V

10k

18 kA

CHSA

CHSA

UL and CSA for use in a
Type CH loadcenter.

Plug on to the
120/240 Single
loadcenter bus;
see instructions.

60

L1-N 150V, L1-N 600V, 3k
L-L 300V L-L 1000V

10k

18 kA

BRSURGECSA

BRSURGECSA

CSA for use in an Eaton
Type BR loadcenter.

Plug on to the
120/240 Single
loadcenter bus;
see instructions.

60

L1-N 150V, L1-N 600V, 3k
L-L 300V L-L 1000V

10k

18 kA

CHQSA

CHQSA

This device is UL classified to be used
in place of Square D Type QO surge
arresters (refer to Pub-23974).

Plug on to the
120/240 Single
loadcenter bus;
see instructions.

60

L1-N 150V, L1-N 600V, 3k
L-L 300V L-L 1000V

10k

18 kA

2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2

Notes
1 MCOV: Maximum Continuous Operating Voltage that may be applied to the device per mode.
2 VPR: Voltage Protection Rating is the measured limiting voltage after a surge event.
3 I : Nominal Discharge Current is the current that the device can withstand for 15 impulses.
n
4 SCCR: The amount of current the product can withstand under short-circuit conditions.
5 Surge Current Capacity: The maximum one-time surge current rating per phase.

2
2
2

For warranty details, go to www.eaton.com/surgetrap.

2
2
2
2
2
2
2
V1-T2-8

Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com

Residential Standby Backup Power Solutions
3.1

Standby Generators
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Application Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Features, Benefits and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Standards and Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Air-Cooled Generators. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Liquid-Cooled Generators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sizing Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3.2

V1-T3-4
V1-T3-5
V1-T3-6
V1-T3-6

V1-T3-8
V1-T3-10

Automatic Transfer Switches
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Application Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Standards and Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Standard Automatic Transfer Switches. . . . . . . . . . . . . . . . . . . . . .
Green Automatic Transfer Switches—
Featuring Active Load Management Technology . . . . . . . . . . . . .
ATS Ready Loadcenter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3.4

V1-T3-3

Portable Generators
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3.3

V1-T3-2
V1-T3-2
V1-T3-2
V1-T3-2
V1-T3-3
V1-T3-3

V1-T3-11
V1-T3-11
V1-T3-12
V1-T3-13

3
3
3
3
3
3
3
3
3
3
3

V1-T3-13

3

V1-T3-13

3

V1-T3-14
V1-T3-15

Manual Transfer Switches
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Application Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Features, Benefits and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Standards and Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reference Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Manual Transfer Switches and Generator Panels Selection . . . . . .
Power Inlet Boxes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3

V1-T3-16
V1-T3-16
V1-T3-16
V1-T3-17
V1-T3-17
V1-T3-18
V1-T3-18

3
3
3
3
3

V1-T3-18

3

V1-T3-19
V1-T3-19

3
3
3
3
3
3
3
3
3
3

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T3-1

3.1
3

Residential Standby Backup Power Solutions
Standby Generators

Contents

Standby Generator Systems

Description

3

Page

Standby Generators
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection. . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sizing Guidelines . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .

3
3
3

EGENX20A

3

V1-T3-3
V1-T3-3
V1-T3-5
V1-T3-6
V1-T3-6

EGEN70

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

Product Description
A standby generator system
is a package of equipment
specifically designed to
provide substitute electrical
power to a residence in the
event of a utility power
outage. These systems are
comprised of a generator,
transfer switch and the
connections necessary for
installation. Eaton’s standby
generator line consists of
air-cooled and liquid-cooled
models ranging from 8000
watts up to 150,000 watts.

Air-Cooled Standby
Eaton’s air-cooled generators
range from 8 to 20 kW and
these units are perfect for
automatically backing up
every circuit within a home
such as air conditioner units,
refrigerators, lighting, furnace
fans, sump pumps and water
pumps.

3

Application Description
Eaton’s 14, 17 and 20 kW aircooled standby generators
offer fully automatic
operation and provide most
homeowners with enough
power for complete whole
house comfort. These units
all operate at ultra quiet
66 dB, or less, sound level.

Liquid-Cooled Standby
Eaton’s liquid-cooled
generators feature automotive
style engines that range from
22 to 150 kW of power
output. These units run so
quietly that you’ll forget that
you own a generator until you
need it. These units are
available in steel or aluminum
enclosures and are available in
single- and three-phase in four
voltages: 120/240V, singlephase; 120/208V, three-phase;
240V, three-phase; and 277/
480V, three-phase.

Standby generator systems
are most often used in
residential, agricultural
and light commercial
applications. Comfort and
safety are key concerns
of many homeowners
who are dependent on
an uninterrupted supply
of electricity.
The increase in our
dependence on power is
due in part to the popularity of
home offices and in-home
health care. Many regions of
the United States experience
periodic power outages
due to extreme weather
conditions such as ice and
snowstorms, heat waves,
tornadoes or hurricanes.
Eaton highly recommends
that any generator system
be installed by a qualified
electrician and/or generator
installer.

3
3
3
3
3
3
V1-T3-2

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Features, Benefits
and Functions
Eaton’s generator systems
offer a wide range of
features. All systems feature:
●
●

●
●

Powerful engines
Reliable Eaton transfer
switches and control
systems using switching
duty rated circuit breakers
Weekly exercise function
Automatic transfer
systems feature automatic
start/stop

Standards and
Certifications
●

●

●

CSA, cUL® and UL 2200
listed and approved
All transfer switches are
UL 67 and UL 1008 listed
as “Transfer Switches”
All generators are
UL 2200 listed

Residential Standby Backup Power Solutions
Standby Generators

3.1

Catalog Number Selection

3
3

Air-Cooled Generators

EGENX 20 A
Type
Eaton generator
EGENX Series

Rated Power
(LP/NG)
8 = 8/7 kW
11 = 11/10 kW
14 = 14/14 kW
17 = 17/16 kW
20 = 20/18 kW

3
3

Enclosure
A
= Aluminum
Blank = Steel

3
3
3

Liquid-Cooled Generators

3

EGEN 22 A L A N
kW Rating
22
60
25
70
27
80
30
100
36
130
45
150
48

Voltage Required
A = Single-phase 120/240V
G = Three-phase 208V
J = Three-phase 240V
K = Three-phase 480V

Fuel Type
N = Natural gas
L = Liquid propane

3

Enclosure
A = Aluminum
S = Steel

SCAQMD Compliance
N = No
Y = Yes

3
3
3
3

Product Selection

3

Air-Cooled Generators

3

Maximum Rated
Rated
Amperes
Main Line
Power kW at 240 Vac
Circuit Breaker
(LP/NG)
(LP/NG)
Amperes

Enclosure
Material

Engine
Size

Number of
Cylinders

8/7

33.3/29.2

35

Steel

410 cc

1

11/10

45.8/41.7

50

Steel

530 cc

14/14

58.3/58.3

60

Steel

17/16

70.8/66.6

65

17/16

70.8/66.6

20/18

83.3/75.0

3

Sound
GFI
SCAQMD Emissions
Receptacle Compliant (dB at 7m)

Limited
Warranty (yrs)

Catalog
Number

Liquid propane/
natural gas

No

Yes

62

5

EGENX8

3

2

Liquid propane/
natural gas

No

Yes

63

5

EGENX11

3

990 cc

2

Liquid propane/
natural gas

No

Yes

66

5

EGENX14

3

Steel

990 cc

2

Liquid propane/
natural gas

Yes

Yes

66

5

EGENX17

3

65

Aluminum

990 cc

2

Liquid propane/
natural gas

Yes

Yes

66

5

EGENX17A

3

90

Aluminum

990 cc

2

Liquid propane/
natural gas

Yes

Yes

66

5

EGENX20A 1

Fuel Type

3
3

Note
1 Includes No. EGENFASCIA as standard.

3
3
3
3
3
3
3
Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T3-3

3.1
3

EGEN48ANAN

3
3

Residential Standby Backup Power Solutions
Standby Generators

Liquid-Cooled Generators 12
Catalog
Number
Prefix

kW
Rating

Voltages
Available

EGEN22

22

A—120/240V, single-phase
G—208V, three-phase

SCAQMD
Compliance

Fuel Type

Enclosure

N—NG/LP field convertible
(Default set up for NG)

A—Aluminum

Y—Yes
(Default Compliant)

N—NG/LP field convertible
(Default set up for NG)

S—Steel

Y—Yes
(Default Compliant)

N—NG/LP field convertible
(Default set up for NG)

A—Aluminum

Y—Yes
(Default Compliant)

N—NG/LP field convertible
(Default set up for NG)

S—Steel

Y—Yes
(Default Compliant)

N—NG/LP field convertible
(Default set up for NG)

A—Aluminum

Y—Yes

J—240V, three-phase

3

EGEN25

25

3

A—120/240V, single-phase
G—208V, three-phase
J—240V, three-phase

3

EGEN27

27

A—120/240V, single-phase
G—208V, three-phase

3

J—240V, three-phase
EGEN30

30

3

A—120/240V, single-phase
G—208V, three-phase
J—240V, three-phase

3

EGEN36

36

A—120/240V, single-phase
G—208V, three-phase

3

J—240V, three-phase

N—No

K—480V, three-phase

3

EGEN45

45

A—120/240V, single-phase
G—208V, three-phase

3

N—NG/LP field convertible
(Default set up for NG)

S—Steel

J—240V, three-phase

Y—Yes
N—No

K—480V, three-phase

3

EGEN48

48

A—120/240V, single-phase

3

G—208V, three-phase

3

K—480V, three-phase

N—NG/LP field convertible
(Default set up for NG)

A—Aluminum

J—240V, three-phase
EGEN60

60

A—120/240V, single-phase

3

G—208V, three-phase

3

K—480V, three-phase

J—240V, three-phase
EGEN70

70

A—120/240V, single-phase

3

G—208V, three-phase

3

K—480V, three-phase

J—240V, three-phase
EGEN80

80

A—120/240V, single-phase

3

G—208V, three-phase

3

K—480V, three-phase

J—240V, three-phase
EGEN100

3

100

A—120/240V, single-phase

Y—Yes
N—No

N—Natural gas

A—Aluminum

Y—Yes

L—Liquid propane

S—Steel

N—No

N—Natural gas

A—Aluminum

Y—Yes

L—Liquid propane
N—Natural gas

N—No
A—Aluminum

L—Liquid propane
N—Natural gas

Y—Yes
N—No

A—Aluminum

Y—Yes

G—208V, three-phase
J—240V, three-phase

3

L—Liquid propane

N—No

K—480V, three-phase
EGEN130

3

130

A—120/240V, single-phase

N—Natural gas

A—Aluminum

Y—Yes

G—208V, three-phase
J—240V, three-phase

3

L—Liquid propane

N—No

K—480V, three-phase
EGEN150

3

150

A—120/240V, single-phase

N—Natural gas

A—Aluminum

Y—Yes

G—208V, three-phase
J—240V, three-phase

3

L—Liquid propane

N—No

K—480V, three-phase

3

Notes
1 All liquid-cooled models suitable for “optional” standby backup power only, as dictated by NEC Article 702/NFPA 70. Not suitable for legally required
“emergency” applications as required by NEC Article 700/NFPA 110.
2 Models 70–150 kW include battery. For all other liquid-cooled models, battery must be furnished by others.

3
3
V1-T3-4

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Residential Standby Backup Power Solutions
Standby Generators

3.1

Accessories

3
3

Generator Accessories—Air and Liquid-Cooled Generators
Catalog
Number

3

Air-cooled transportation cart

EGENCART

3

Bisque paint kit for 2008 model lineup

EGENPAINT

Display shell—bisque color

EGENSHELL

Generator fascia for air-cooled models. Bisque color (included as standard on EGENX20A models)

EGENFASCIA

3

Wireless remote monitor for air-cooled and liquid-cooled generators. Compatible with 2008 models or newer. USA only

EGENMOBILE

3

EGENMOBILE adapter wire harness kit required for liquid-cooled generators only. 2008 models or newer. USA only

EGENKIT

Basic remote wireless monitor. Compatible with air/liquid-cooled models 8–150 kW. 2008 models or newer

5928CH

Remote monitor adapter kit for liquid-cooled units only—must be ordered w/5928CH basic remote monitor. 2008 models or newer

5958CH

3

Cold weather kit for all air-cooled generator models (8–20 kW). Battery and crankcase warmer

6212CH

22, 27, 36, 45 and 60 kW (2.4L) cold weather kit

5630CH

3

25 and 30 kW (1.5L) cold weather kit

6175CH

100 and 130 kW (6.8L) cold weather kit

5633CH

48 (5.4L), 80 (4.6L) and 70 and 150 kW (6.8L) cold weather kit

5632CH

25 and 30 kW (1.6L) cold weather kit for models prior to February 2012

5629CH

48 kW (4.2L) cold weather kit for models prior to February 2012

5631CH

3

25 and 30 kW extreme cold weather kit 1.5L engine

6174CH

3

25 and 30 kW extreme cold weather kit 1.6L engine (prior to February 2012)

5615CH

22, 27, 36, 45 and 60 kW extreme cold weather kit for 2.4L engine

5616CH

48 kW extreme cold weather kit for 5.4L engine

6204CH

48 kW extreme cold weather kit for 4.2L engine (prior to February 2012)

5618CH

70, 100 and 130 kW generator extreme cold weather kit for 6.8L engine gear drive

5620CH

80 kW extreme cold weather kit for 4.6L engine

5619CH

150 kW generator extreme cold weather kit for 6.8L engine direct drive

5667CH

Extreme cold weather kit (engine warmer) for air-cooled 8–10 kW, 410/530 cc engines (after April 2010)

5863CH

Extreme cold weather kit (engine warmer) for air-cooled 14–20 kW, 760/992/999 cc engines (after April 2010)

5864CH

3

8 kW generator maintenance kit 410 cc engine. For #EGENX8 model only

6482CH

3

11 kW generator maintenance kit 530 cc engine. For #EGENX11 model only

6483CH

14 and 17 kW generator maintenance kit, 760/990 cc engine. For #EGENX14 & #EGENX17-17A models only

6484CH

20 kW generator maintenance kit, 999 cc engine. For #EGENX20A model only

6485CH

8 kW generator maintenance kit 410 cc engine. #EGEN8 vintage model only

5662CH

10 kW generator maintenance kit 530 cc engine. #EGEN10 vintage model only

5663CH

14 and 17 kW generator maintenance kit, 760/990 cc engine. #EGEN14 & EGEN17-17A vintage models only

5664CH

20 kW generator maintenance kit, 999 cc engine. #EGEN20A vintage model only

5665CH

22 and 27 kW generator maintenance kit, 2.4L engine

5656CH

25 and 30 kW generator maintenance kit, 1.5L engine

6176CH

25 and 30 kW generator maintenance kit, 1.6L engine (prior to February 2012)

5655CH

36 kW generator maintenance kit, 2.4L engine

5984CH

45 kW generator maintenance kit, 2.4L engine

6172CH

48 kW generator maintenance kit, 4.2L engine

5658CH

60 kW generator maintenance kit, 2.4L engine

6171CH

80 kW generator maintenance kit, 4.6L engine

5985CH

70, 100, 130 and 150 kW generator maintenance kit, 6.8L engine

5660CH

Description
General Accessories

EGENMOBILE

Cold Weather Kits

Extreme Cold Weather
Kits

Maintenance Kits

Wireless Remote Monitoring

3

3

Cold Weather Kits

3
3

Extreme Cold Weather Kits

3
3
3
3

Maintenance Kits

3
3
3
3
3
3
3
3
3
3

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T3-5

3.1
3
3
3

Residential Standby Backup Power Solutions
Standby Generators

Sizing Guidelines

Dimensions

When selecting the essential circuits that will be switched to
“Backup Power,” it is important that the sum of the combined
circuit loads does not exceed the wattage/amperage capacity
of the generator. To help you with your selection of essential
circuits, please add up the total wattage of all electrical devices
to be connected at one time. This total should NOT be greater
than the generator’s wattage capacity.

Approximate Dimension in Inches (mm)
Air-Cooled Standby
Catalog
Number

Length

Width

Height

Weight in
Lbs (kg)

EGENX8

48.00 (1219.2)

25.00 (635.0)

29.00 (736.6)

340 (154.4)

Refer to Eaton Generator Sizing Guide Publication Number
TD00405018E and consult with a trained professional.

EGENX11

48.00 (1219.2)

25.00 (635.0)

29.00 (736.6)

387 (175.7)

EGENX14

48.00 (1219.2)

25.00 (635.0)

29.00 (736.6)

439 (199.3)

3

Circuit Selection 123

EGENX17

48.00 (1219.2)

25.00 (635.0)

29.00 (736.6)

455 (206.6)

48.00 (1219.2)

25.00 (635.0)

29.00 (736.6)

421 (191.1)

3

Device

Common
Running Watts

EGENX17A
EGENX20A

48.00 (1219.2)

25.00 (635.0)

29.00 (736.6)

451 (204.8)

3

Air conditioner (12,000 btu)

1700

Air conditioner (24,000 btu)

3800

Liquid-Cooled Standby

Air Conditioner (40,000 btu)

6000

Battery charger (20 amp)

500

Catalog
Number

Length

Width

Height

Weight in
Lbs (kg)

3

Circular saw (6-1/2-inch)

800–1000

EGEN22

62.00 (1574.8)

29.00 (736.6)

34.00 (863.6)

895 (406.3)

5750

EGEN25

63.00 (1600.2)

30.00 (762.0)

35.00 (889.0)

875 (397.3)

3

Clothes dryer (gas)

700

EGEN27

64.00 (1625.6)

31.00 (787.4)

36.00 (914.4)

891 (404.5)

Clothes washer

1150

EGEN30

60.00 (1651.0)

32.00 (812.8)

37.00 (939.8)

935 (424.5)

3

Coffee maker

1750

EGEN36

77.00 (1955.8)

34.00 (863.6)

45.00 (1143.0)

1683 (764.1)

Compressor (1 hp)

2000

EGEN45

78.00 (1981.2)

35.00 (889.0)

46.00 (1168.4)

1414 (642.0)

3

Compressor (1/2 hp)

1400

EGEN48

79.00 (2006.6)

36.00 (914.4)

47.00 (1193.8)

1703 (773.2)

Compressor (3/4 hp)

1800

3

EGEN60 4

80.00 (2032.0)

37.00 (939.8)

48.00 (1219.2)

1650 (749.1)

Curling iron

700

EGEN70 4

97.00 (2463.8)

37.00 (939.8)

48.00 (1219.2)

2185 (992.0)

3

Dehumidifier

650

EGEN80 4

Electric blanket

400

3

Electric range (per element)

1500

Electric skillet

1250

3

Freezer

700

Furnace fan (3/5 hp)

875

3

Garage door opener

500–750

Hair dryer

1200

3

Hand drill

250–1100

3
3

3

Clothes dryer (electric)

Iron

1200

3

Jet pump

800

3

Light bulb

100

Microwave oven

700–1000

3

Milk cooler

1100

Oil burner on furnace

300

3

Oil fired space heater (140,000 btu)

400

Oil fired space heater (30,000 btu)

150

3

Oil fired space heater (85,000 btu)

225

Radio

50–200

3

Refrigerator

700

Slow cooker

200

3

Submersible pump (1 hp)

2000

Submersible pump (1/2 hp)

1500

3

Submersible pump (1-1/2 hp)

2800

3

Sump pump

800–1050

Table saw (10-inch)

1750–2000

3

Television

200–500

Toaster

1000–1650

115.00 (2921.0)

36.80 (934.7)

79.00 (2006.6)

2010 (912.5)

4

116.00 (2946.4)

36.80 (934.7)

80.00 (2032.0)

2705 (1228.1)

EGEN130 4

117.00 (2971.8)

36.80 (934.7)

81.00 (2057.4)

2873 (1304.3)

EGEN150 4

118.00 (2997.2)

36.80 (934.7)

82.00 (2082.8)

2666 (1210.4)

EGEN100

Notes
1 The rated wattage of lights can be taken from light bulbs. The rated wattage of tools,
appliances and motors can usually be found on a data plate or decal affixed to the device.
2 If the appliance, tool or motor does not give wattage, multiply 120 volts times the ampere
rating to determine watts (volts x amps = watts) for single-phase only.
3 Some electric motors (induction types) require about three times more watts of power for
starting than for running. This surge lasts for only a few seconds. Be sure you allow for this
high starting wattage when selecting electrical devices that will be energized by the backup
power system:
Figure the watts required to start the largest motor.
Add that to the total running watts of all other connected loads.
4 All weights provided for steel enclosures only.

3
V1-T3-6

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Residential Standby Backup Power Solutions
Portable Generators

3.2

Contents

EGENP8000EX

Description
Portable Generators
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page

3

V1-T3-8
V1-T3-10

3

3
3
3
3
3
3
3
3

Product Description

Application Description

Whereas permanently
installed standby systems are
designed for larger homes,
small businesses or
secondary residences,
portable generators are
primarily used for smaller
homes, essential loads,
construction sites, camping,
tailgating and wherever
portable temporary power
is required.

Portable generator systems
are primarily used for smaller
homes or for construction
sites where temporary power
is required. Permanently
installed standby systems
are designed for larger
homes, small businesses
or secondary residences,
such as vacation homes
and cabins, that require
uninterrupted power for
critical loads.

3

Standards and
Certifications
●

3

UL Listed

3
3
3
3
3
3

As the name indicates and
due to physical size and
weight, portable generators
can easily be transported
from one location to another.

3
3

Designed for outdoor use
only, common applications
vary from homes to camping
to construction sites,
providing backup power
everywhere electrical power
is needed.

3
3
3

Catalog Number Selection

3

Portable Generators

3
EGEN P 8000 E X

Eaton generator
Type
P = Portable

Power Output
5500 = 5.5 kW
6500 = 6.5 kW
7000 = 7.5 kW
8000 = 8 kW
15000 = 15 kW
17500 = 17.5 kW

Startup Method
Blank = Manual/recoil only
E
= Electric and/or
manual/recoil

3
3

Model
Blank = General purpose
CA
= General purpose
“CARB” compliant
(CA only)
X
= XG Series

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

3
3
3
V1-T3-7

3.2
3

Portable Generators

3

Fuel
Engine
Tank
Running Starting Displacement/ Startup Capacity
Watts Watts Type
Method (gal) 1

3
3

Portable Generators

Product Selection

3

3

Residential Standby Backup Power Solutions

Approx.
Running
Time at
1/2 load Battery Outlets
(hrs)
Included Configuration

Warranty
Residential/
Commercial Catalog
(yrs)
Number

General Purpose (49-State)
EGENP5500

5500

6875

389 cc/OHV

Manual 7.2

10

No

1 x 30A L14-30R (twist lock), 2 x 20A 5-20R duplex

2/1 Ltd

EGENP5500

EGENP6500

6500

8125

389 cc/OHV

Manual 7.2

10

No

1 x 30A L14-30R (twist lock), 2 x 20A 5-20R duplex

2/1 Ltd

EGENP6500

EGENP6500E

6500

8125

389 cc/OHV

Manual/ 7.2
electric

10

Yes

1 x 30A L14-30R (twist lock), 2 x 120A 5-20R duplex

2/1 Ltd

EGENP6500E

EGENP7500E

7500

9375

420 cc/OHV

Manual/ 8.0
electric

12

Yes

1 x 30A L14-30R (twist lock), 2 x 20A 5-20R duplex

2/1 Ltd

EGENP7500E

EGENP15000E

15000

22500

992 cc/OHVI

Manual/ 16.0
electric

12

Yes

1 x 50A 14-50R, 1 x 30A L14-30R (twist lock),
2 x 30A L5-30R (twist lock), 1 x 20A 5-20R duplex,
1 x 20A GFCI 5-20R duplex

2/1 Ltd

EGENP15000E

EGENP17500E

17500

26250

992 cc/OHVI

Manual/ 16.0
electric

10

Yes

1 x 50A 14-50R, 1 x 30A L14-30R (twist lock),
1 x 30A L5-30R (twist lock),1 x 20A 5-20R duplex,
1 x 20A 5-20R GFCI duplex

2/1 Ltd

EGENP17500E

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
Notes
1 Requires gasoline as fuel to operate.

3

All 120/240V. Required gasoline as fuel.

3
3
3
3
3
V1-T3-8

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

3.2

Residential Standby Backup Power Solutions
Portable Generators

Portable Generators, continued
Fuel
Engine
Tank
Running Starting Displacement/ Startup Capacity
Watts Watts Type
Method (gal) 1

Approx.
Running
Time at
1/2 load Battery Outlets
(hrs)
Included Configuration

3
Warranty
Residential/
Commercial Catalog
(yrs)
Number

XG Series
EGENP7000EX

7000

8750

407 cc/OHVI

Manual/ 9
electric

10

Yes

1 x 30A L14-30R (twist lock), 2 x 20A GFCI 5-20R duplex 2/1 Ltd

EGENP7000EX

3
3
3
3
3

EGENP8000EX

8000

10000

407 cc/OHVI

Manual/ 10
electric

10

Yes

1 x 30A L14-30R (twist lock), 2 x 20A GFCI 5-20R duplex 2/1 Ltd

EGENP8000EX

3
3
3

EGENP10000EX

10000

12500

530 cc/OHVI

Manual/ 10
electric

10

Yes

1 x 50A 14-50R, 1 x 30A L14-30R (twist lock),
2/1 Ltd
1 x 30A L5-30R (twist Lock), 2 x 20A GFCI 5-20R duplex

EGENP10000EX

3
3
3
3

CARB Compliant (Required in California Only)
EGENP5500CA

5500

6875

389 cc/OHV

Manual 7.2

10

No

1 x 30A L14-30R (twist lock), 2 x 20A GFCI 5-20R duplex 2/1 Ltd

EGENP5500CA

3
3
3
3

EGENP6500CA

6500

8125

389 cc/OHV

Manual 7.2

10

No

1 x 30A L14-30R (twist lock), 2 x 120A 5-20R duplex

2/1 Ltd

EGENP6500CA

3
3
3
3

Notes
1 Requires gasoline as fuel to operate.

3

All 120/240V. Required gasoline as fuel.

3
3
3
3
3
3
3
3
Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T3-9

3.2
3

Residential Standby Backup Power Solutions
Portable Generators

Dimensions
Approximate Dimension in Inches (mm)

3

Portable Generators

3

Catalog
Number

Length

Width

Height

Weight
Lbs (kg)

3

EGENP5500

27.25 (692.2)

27.00 (685.8)

25.00 (635.0)

171.0 (77.6)

3

EGENP6500

27.25 (692.2)

27.00 (685.8)

25.00 (635.0)

175.0 (79.5)

EGENP6500E

27.25 (692.2)

27.00 (685.8)

25.00 (635.0)

186.0 (84.4)

3

EGENP7500E

27.25 (692.2)

27.00 (685.8)

25.00 (635.0)

191.5 (86.9)

EGENP15000E

48.50 (1231.9)

31.00 (787.4)

39.50 (1003.3)

363.0 (164.8)

3

EGENP17500E

48.50 (1231.9)

31.00 (787.4)

39.50 (1003.3)

390.0 (177.1)

EGENP7000EX

31.00 (787.4)

25.50 (647.7)

28.00 (711.2)

245.0 (111.2)

3

EGENP8000EX

31.00 (787.4)

25.50 (647.7)

28.00 (711.2)

235.0 (106.7)

3

EGENP10000EX

30.00 (762.0)

29.50 (749.3)

31.00 (787.4)

300.0 (136.2)

EGENP5500CA

27.25 (692.2)

27.00 (685.8)

25.00 (635.0)

170.9 (77.6)

3

EGENP6500CA

27.25 (692.2)

27.00 (685.8)

25.00 (635.0)

177.0 (80.3)

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
V1-T3-10

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

3.3

Residential Standby Backup Power Solutions
Automatic Transfer Switches

Contents

Residential Automatic Transfer Switches

Description

Page

Automatic Transfer Switches
Standards and Certifications . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
ATS Ready Loadcenter . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .

V1-T3-12
V1-T3-12
V1-T3-13
V1-T3-14
V1-T3-15

3
3
3
3
3
3
3
3
3
3

Product Description

3

Application Description

3

50, 100, 150, 200 and 400A
Fully Automatic

Green Line of Automatic
Transfer Switches

50, 100, 150, 200 and 400A
Switches

All Eaton automatic transfer
switches (ATS) monitor utility
and generator voltages and
will automatically connect to
the appropriate source of
power. Eaton offers two
types of automatic transfer
switches to suit your personal
backup power needs—the
standard ATS EGSX series
with load shedding
capabilities and the Green
ATS EGSU series that
provides a truly active load
management solution.

With the rising cost of
commodities and fuel
in today’s economy,
consumers are concerned
with maximizing the value
of their purchases.

100, 200 and 400A switches
are capable of “whole house”
power transfer in residential/
small business applications.

Electrical loads are now
intelligently managed with
Eaton’s Green Line of
automatic transfer switches.
The active load management
inside each Green ATS allows
the consumer to use 100% of
the power rated output of the
generator and/or use a
smaller generator, reducing
upfront installation costs and
saving on ongoing fuel
consumption costs.
As a part of Eaton’s
commitment to quality,
every Green ATS, at no
extra cost, will ship with a
CHSPT2ULTRA whole surge
protector, which will help
prevent potential damage
to valued electronics caused
by power surges in the
utility line.

3
3
3

50A—Indoor Installation—Selected Load Pre-Wired
50A
Indoor Transfer
Switch

Meter
Standby
Generator

100/200A
Service Panel

3
3

Fuel Supply
(NG or LP)

3
3

Air Conditioner

100/200A—Outdoor Installation—Whole House Pre-Wired
Service
Disconnect

3
3

Meter

100/200A
Outdoor Transfer Switch
Sound
Attenuated
Enclosure

3
3

Sound
Attenuated
Enclosure

Standby
Generator

3

Low Voltage
Disconnect

3
3
3
3

Fuel Supply
(NG or LP)

Air Conditioner

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

100/200A
Service Panel

V1-T3-11

3
3

3.3
3
3

Residential Standby Backup Power Solutions
Automatic Transfer Switches

Standards and
Certifications
●

UL 1008 listed

3
3
3

Catalog Number Selection

3

Standard Automatic Transfer Switches—EGSX Series

3

E GSX 200

3

Manufacturer
Eaton

3

Type
Generator
transfer switch
EGSX Series

3
3

Ampere
Rating
50 = 50A
100 = 100A
150 = 150A
200 = 200A
400 = 400A

NSEA
Loadcenter
(CH Type, Integral)
Blank = None
L12 = 12 circuits N1
L12R = 12 circuits N3R
L24R = 24 circuits N3R

Service Entrance Rated
NSEA = Service entrance
(normal source only)
A
= Non-service entrance

3
3

Green Automatic Transfer Switches—EGSU Series

E GSU 200

3
3

Manufacturer
Eaton

3
3

Type
Generator
universal transfer
switch EGSU
“Green” Series

Ampere
Rating
100 = 100A
150 = 150A
200 = 200A
400 = 400A

NSE ACA

Loadcenter
(CH Type, Integral)
Blank = None
L24 = 24 circuits

Service Entrance Rated
NSE = Service entrance
(normal source only)
Blank = Non-service entrance

3
3
3
3
3
3
3
3
3
3
3
3
3
V1-T3-12

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Load Management
ACA = Active load management

Residential Standby Backup Power Solutions
Automatic Transfer Switches

3.3

Product Selection
EGSX50L12R

EGSU200NSEACA

CHSPT2ULTRA 5

3
3

Standard Automatic Transfer Switches 1

3

Service
Ampere
Entrance
Rating Voltage Rated

No. of
Load
Contactor
Shed
Wire Size
Contacts Range(s)

Recommended
No. of
Withstand
No. of
Frequency Enclosure Generator
Catalog
Cables
Current (rms) Circuits
Type
Sizes (kW) 3 Number
per Phase at 240 Vac
Included 2 (Hz)

50

120/240 No

2

#14–#6

1

5000

12

50/60

NEMA 1
(indoor)

8, 11

EGSX50L12

50

120/240 No

2

#14–#6

1

5000

12

50/60

NEMA 3R
(outdoor)

8, 11

EGSX50L12R

100

120/240 No

2

#14–#2/0

1

10,000

—

50/60

NEMA 3R
(outdoor)

8, 11, 14

EGSX100A

100

120/240 Yes

2

#14–#2/0

1

10,000

—

50/60

NEMA 3R
(outdoor)

8, 11, 14

EGSX100NSEA

3

100

120/240 No

2

#14–#2/0

1

25,000

24

50/60

NEMA 3R
(outdoor)

8, 11, 14

EGSX100L24RA

3

150

120/240 Yes

2

#4–300 kcmil

1

25,000

—

50/60

NEMA 3R
(outdoor)

14, 17, 20

EGSX150NSEA

3

200

120/240 No

2

#4–300 kcmil

1

25,000

—

50/60

NEMA 3R
(outdoor)

14, 17, 20

EGSX200A

3

200

120/240 Yes

2

#4–300 kcmil

1

25,000

—

50/60

NEMA 3R
(outdoor)

14, 17, 20

EGSX200NSEA

3

400

120/240 Yes

2

750 kcmil–2
1/2
300 kcmil–1/0

35,000

—

50/60

NEMA 3R
(outdoor)

>20

EGSX400NSEA

3

Contactor
Wire Size
Range(s)

No. of
Cables
per Phase

Withstand
No. of
Current (rms) Circuits
at 240 Vac
Included 2

Frequency
(Hz)

Enclosure
Type

100

120/240 No

#14–#2/0

1

10,000

—

50/60

100

120/240 Yes

#14–#2/0

1

10,000

—

100

120/240 No

#14–#2/0

1

10,000

150

120/240 Yes

#4–300 kcmil

1

200

120/240 No

#4–300 kcmil

200

120/240 Yes

400

120/240 Yes

3
3

3
3

Green Automatic Transfer Switches 4—Featuring Active Load Management Technology
Service
Ampere
Entrance
Rating Voltage Rated

3

Recommended
Generator
Sizes (kW) 3

Catalog
Number

NEMA 3R
(outdoor)

8, 11, 14

EGSU100ACA

3

50/60

NEMA 3R
(outdoor)

8, 11, 14

EGSU100NSEACA

3

24

50/60

NEMA 3R
(outdoor)

8, 11, 14

EGSU100L24RACA

3

25,000

—

50/60

NEMA 3R
(outdoor)

14, 17, 20

EGSU150NSEACA

3

1

25,000

—

50/60

NEMA 3R
(outdoor)

14, 17, 20

EGSU200ACA

3

#4–300 kcmil

1

25,000

—

50/60

NEMA 3R
(outdoor)

14, 17, 20

EGSU200NSEACA

3

750 kcmil–2
300 kcmil–1/0

1/2

35,000

—

50/60

NEMA 3R
(outdoor)

>20

EGSU400NSEACA

3

3

3

Notes
1 Standard ATS “EGSX” Series compatible with Eaton generators only.
2 Uses CH type circuit breakers.
3 For reference only. Generator size must be determined with proper/actual load calculations.
4 UNIVERSAL ATS: compatible with any single-phase, 120/240V generator brand.
5 Whole house surge Cat. No. CHSPT2ULTRA included in every Green ATS “EGSU” Series.

3
3
3
3
3
3
3

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T3-13

3.3
3
3
3
3
3
3
3
3

Automatic Transfer Switches

ATS Ready Loadcenter
From the far-reaching power
failures brought on by
hurricanes and snow/ice
storms, to the increasing
power outage concerns and
an aging electrical
infrastructure, backup power
is more important than ever.
Eaton’s ATS Ready loadcenter
addresses future backup
power needs by enabling a
fast, efficient installation of an
automatic transfer switch kit
to convert from utility power
to generator power. The ATS

3
3

Residential Standby Backup Power Solutions

Ready loadcenter gives
homebuilders and electrical
contractors the flexibility to
install a generator ready
system or to install a
loadcenter and easily add an
ATS in the future. Backup
power had never been that
versatile before.

ATS Ready Loadcenter Features
●
CH Premium Type 200A
single-phase MCB
36-circuit loadcenter
●
50A ATS “EGSX” type kit
for factory or field
installation (compatible
with Eaton generators only)
●
22 circuits for nonessential loads and
14 circuits for essential
backup power loads
●
Versatile, space-saving
design

ATS Ready Loadcenter
Description

Catalog Number

CH36B200EGP

ATS Ready loadcenter
Kit CHEGSX50KIT must be ordered separately
Loadcenter only. Includes provision for ATS kit

CH36B200EGP

CHEGSX50KIT

ATS “EGSX” kit for ATS Ready loadcenter
Field-installable automatic transfer switch kit
ATS Ready loadcenter CH36B200EGP must be ordered separately
Intuitive, easy installation
Compatible with Eaton generators only

CHEGSX50KIT

CH36B200EGPK

ATS Ready LC with factory-installed ATS kit
Factory assembled
Compatible with Eaton generator only. Generator needed to complete backup power system
Recommended Eaton generators models:
8/7 kW–Catalog #EGENX8
11/10 kW–Catalog #EGENX11

CH36B200EGPK

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
V1-T3-14

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

●

●
●

●
●

For use with 8 or 11 kW
air-cooled generators
CH cover included
Lifetime warranty on CH
loadcenter and breakers
NEMA 1 design
UL Listed

Residential Standby Backup Power Solutions
Automatic Transfer Switches

3.3

Dimensions
Approximate Dimension in Inches (mm)

3

Automatic Transfer Switches

3

Catalog Number

Width

Height

Depth

Weight
Lbs (kg)

3

EGSX50L12

14.25 (362.0)

21.00 (533.4)

4.00 (101.6)

25 (11.33)

EGSX50L12R

14.25 (362.0)

21.00 (533.4)

6.00 (152.4)

29 (13.15)

3

EGSX100A

14.46 (367.3)

16.87 (428.5)

5.32 (135.1)

25 (11.33)

EGSX100NSEA

14.46 (367.3)

16.87 (428.5)

5.32 (135.1)

28 (12.70)

EGSX100L24RA

14.46 (367.3)

29.33 (744.0)

5.32 (135.1)

38 (17.24)

EGSX200A

14.46 (367.3)

25.08 (637.0)

5.25 (133.4)

35 (15.87)

EGSX150NSEA

14.46 (367.3)

29.20 (741.7)

5.32 (135.1)

45 (20.41)

EGSX200NSEA

14.46 (367.3)

29.20 (741.7)

5.32 (135.1)

45 (20.41)

EGSU100L24RACA 14.46 (367.3)

29.33 (745.0)

5.32 (135.1)

38 (17.24)

EGSU100ACA

14.46 (367.3)

16.87 (428.5)

5.32 (135.1)

25 (11.33)

EGSU100NSEACA 14.46 (367.3)

16.87 (428.5)

5.32 (135.1)

28 (12.70)

EGSU150NSEACA 14.46 (367.3)

29.20 (741.7)

5.32 (135.1)

45 (20.41)

EGSU200ACA

14.46 (367.3)

25.08 (637.0)

5.25 (133.4)

35 (15.88)

EGSU200NSEACA 14.46 (367.3)

29.20 (741.7)

5.32 (135.1)

45 (20.41)

EGSU400NSEACA 23.14 (587.8)

35.55 (903.0)

10.00 (254.0)

120 (54.43)

CH36B200EGPK

47.50 (1206.5)

3.88 (98.6)

40 (18.14)

14.31 (363.5)

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T3-15

3.4
3

Residential Standby Backup Power Solutions
Manual Transfer Switches

All Panels are Manufactured in the USA and Meet UL 1008

Contents
Description

3

Page

Manual Transfer Switches
Standards and Certifications . . . . . . . . . . . . . .
Reference Information . . . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .

3
3
3

V1-T3-17
V1-T3-17
V1-T3-18
V1-T3-19
V1-T3-19

Learn
Online

3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3

Product Description

Application Description

Features, Benefits and Functions

A manual transfer switch is a
device that is mounted next
to the loadcenter (distribution
panel) in the home or small
business. The manual
transfer switch is used in
conjunction with a portable
backup power generator and
serves the purpose of turning
selected circuits on and off
during a power outage. The
transfer switch panel allows
the owner to start up a
generator to restore power to
critical circuits when utility
power is not available.

Manual transfer switches
are most often used in
residential, agricultural
and light commercial
applications. Comfort and
safety are key concerns
of many homeowners
who are dependent on
an uninterrupted supply
of electricity.

Eaton offers two manual
transfer switch backup power
solutions:

The owner designates which
circuits are critical, such as
the refrigerator and certain
lights. Sometimes called
emergency power panels or
emergency generator panels,
manual transfer switch
panels provide the
homeowner or small
business owner with a safe
and easy way to continue
using electrical appliances
when the utility power
is unavailable temporarily.

●
●

Manual Transfer Switches
●

●

The increase in our
dependence on power is
due in part to the popularity
of home offices and in-home
health care. Various heavily
populated regions of the
United States experience
periodic power outages
due to extreme weather
conditions, such as ice and
snowstorms, heat waves,
tornadoes or hurricanes.
These regions that include
the Pacific Northwest,
Atlantic Coast and the Gulf
Coast are the strongest
markets for portable
generators and manual
transfer switches.

Manual transfer switches
Generator panels

●

●

●

●

●

Panel and components
sold separately
Hardwired generator
connection
Ideal for new construction/
larger loads
Sturdy copper bus
construction
Uses CH and CHNT circuit
breaker types (sold
separately)
Mechanically interlocked
main disconnects to
prevent paralleling of
normal and emergency
power source
Indoor and outdoor
designs available

3
3
3
3
3
V1-T3-16

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Manual Transfer Switch
Indoor Design

Manual Transfer Switch
Indoor/Outdoor Design

3.4

Residential Standby Backup Power Solutions
Manual Transfer Switches

Standards and Certifications
Generator Panels
●

●

●

●

●

●

Mechanically interlocked
main disconnects prevent
paralleling of normal and
emergency power source
Panel and components
sold separately
Integral plug-in generator
connection (power inlet
box)
All circuit breakers are
included—switching
duty rated
Includes dual wattmeters
for load balancing
Indoor and outdoor
designs available

Generator Panel
Indoor Design

●
●

3

UL 67 listed
UL 1008 listed

3
3
3

Reference Information

3
3

Cross-Reference
Ampere
Rating

Catalog Number

Watts

Number
of Circuits

Eaton

Gen/Tran 1

EmerGen 1

Square D

Generac 1

5000

4–8

30

CH48GEN3060R

—

—

QO48M30DSGP

—

15,000

8–16

60

CH816GEN6060

—

—

QO48M60DSGP

—

5000

6

20

CH6EGEN2060

20216

6-5000

—

—

5000

6

20

CH6EGEN2060R

R20216

6-5000 + RTE657

—

—

5000

6

20

CH6EGEN2060SU

—

—

—

—

5000

6

20

CH6EGEN2060RSU

—

—

—

—

7500

10

30

CH10EGEN3060

302110-20

10-7500

—

—

7500

10

30

CH10EGEN3060R

R30211-20

10-7500 + RTE1075

—

—

7500

10

30

CH10EGEN3060SUR

—

—

—

—

7500

10

30

CH10EGEN3060RSU

—

—

—

—

7500

10

30

CH10GEN5030SN

—

—

—

—

7500

10

30

CH10GEN5030RSN

—

—

—

—

12,000

10

50

CH10GEN5050SN

—

—

—

—

12,000

10

50

CH10GEN5050RSN

—

—

—

—

3
3
3
3
3
3
3
3
3
3

Notes
1 Gen/Trans device is not supplied with a power cord.
2 Generac device is 7200 maximum watts on six-circuit device and 12,000 maximum watts on 10-circuit device.

3
3
3
3
3
3

Generator Panel
Outdoor Design

3
3
3
3
3
3
3
3
Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T3-17

3.4
3

Residential Standby Backup Power Solutions
Manual Transfer Switches

Product Selection

3

Manual Transfer Switches and Generator Panels Selection

3

Enclosure
Type

3

Watts

Number
of Circuits

Ampere
Rating

Main/
Emergency
Ampere Rating

Feeder
Breakers

Included
Accessories

Catalog
Number

Standard Manual Transfer Switch

3

NEMA 3R

5000

4–8

30

Provision

Provision

None

CH48GEN3060R

NEMA 1

10,000

8–16

60

Provision

Provision

None

CH816GEN6060

3

Generator Panel

3

NEMA 1

5000

6

20

60/20

5–1P151–1P20

None

CH6EGEN2060

NEMA 3R

5000

6

20

60/20

5–1P151–1P20

None

CH6EGEN2060R

3

NEMA 1

5000

6

20

60/20

5–1P151–1P20

Two-pole surge protector

CH6EGEN2060SUR

NEMA 3R

5000

6

20

60/20

5–1P151–1P20

Two-pole surge protector

CH6EGEN2060RSU

3

NEMA 1

7500

10

30

60/30

6–1P152–1P2012P30

None

CH10EGEN3060

NEMA 3R

7500

10

30

60/30

6–1P152–1P2012P30

None

CH10EGEN3060R

3

NEMA 1

7500

10

30

60/30

7–1P152–1P2012P30

Two-pole surge protector

CH10EGEN3060SUR

3

NEMA 3R

7500

10

30

60/30

7–1P152–1P2012P30

Two-pole surge protector

CH10EGEN3060RSU

3

NEMA 1

7500

10

30

50/30

6–1P15, 2–1P20, 1–2P30

None

CH10GEN5030SN

NEMA 3R

7500

10

30

50/30

6–1P15, 2–1P20, 1–2P30

None

CH10GEN5030RSN

NEMA 1

12,000

10

50

50/50

6–1P15, 2–1P20, 1–2P30

None

CH10GEN5050SN

NEMA 3R

12,000

10

50

50/50

6–1P15, 2–1P20, 1–2P30

None

CH10GEN5050RSN

Switched Neutral Manual Transfer Switch

3
3
3

Power Inlet Boxes

3

Description
Flush flange kit (for use with
generator panel only)

3
3
3
3
3
3
3
3
3

Ampere
Rating

Voltage

Catalog
Number

—

120/240V

CHEGENFKIT

Power inlet box

20

120/240V

EGSPIB20

Power inlet box

30

120/240V

EGSPIB30

Power inlet box

50

120/240V

EGSPIB50

Warranty
Manual Transfer Switch
●
15-year loadcenter
warranty
●
Lifetime branch breaker
warranty
Generator Panel
●
15-year loadcenter
warranty
●
Lifetime branch breaker
warranty

3
3
3
3
3
V1-T3-18

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

3.4

Residential Standby Backup Power Solutions
Manual Transfer Switches

Technical Data and Specifications
●
●
●

●

3

10,000 AIC rating
Switching devices must be circuit breakers
Manual transfer switch must be supplied with neutral
and ground
Power inlet box must be connected to a circuit breaker for
generator protection

3
3
3
3

Installation Diagrams
Manual Transfer Switches—Indoor Installation Diagram
Eaton
Manual Transfer Switch

3

Generator Panels—Indoor Installation Diagram
Utility
Power
Feed

Generator Panel
Utility
Power
Feed

Power
Inlet
Box*

Existing
Main
Power
Panel

Power
Cord*

Power
Inlet
Box*

Existing
Main
Power
Panel

Power
Cord*

(Loadcenter)

(Loadcenter)

Two-Pole, 60A Breaker*
to Feed the Emergency
Generator Panel From
Your Existing Main
Power Panel (Loadcenter)

Two-Pole, 60A Breaker*
to Feed the Emergency
Power Panel From Your
Existing Main Power Panel
Hardwired
Generator*

(Loadcenter)

Electrical
Connection*

* Not Included

Manual Transfer Switches—Outdoor Installation Diagram
Eaton
Manual Transfer Switch

Utility
Power Feed

Power
Inlet
Box*

Existing
Main
Power
Panel

Power
Cord*

Generator*

Electrical Wiring
or Power Cord*

Prewired Connector
for Faster Installation
- Included

Hardwired Electrical Connection*

3
3
3
3
3
3
3

Prewired
Connector
for Faster
Installation -

3

Included

Utility
Power
Feed

3
3

(Loadcenter)

Generator*

3

3

Generator Panel

(Loadcenter)

Two-Pole, 60A Breaker*
to Feed the Emergency
Power Panel From Your
Existing Main Power Panel

3

3
* Not Included

Generator Panels—Outdoor Installation Diagram
Two-Pole, 60A
Breaker* to Feed
the Emergency
Generator Panel
From Your
Existing Main
Power Panel

3

3

Power Cord*

* Not Included

Generator*
*Not Included

3
3

Dimensions

3

Approximate Dimensions in Inches (mm)
Manual Transfer Switch
Enclosure
Type

Height

Width

NEMA 1

16.75 (425.5)

NEMA 3R

13.00 (330.2)

3

Generator Panel
Depth

Weight
Lbs (kg)

Enclosure
Type

Height

Width

Depth

Six-Circuit

10-Circuit

14.31 (363.5)

3.88 (98.5)

25 (11)

NEMA 1

13.23 (336.0)

11.41 (289.8)

4.10 (104.1)

24 (11)

26 (12)

11.00 (279.4)

3.56 (90.4)

14 (6)

NEMA 3R

17.12 (434.8)

9.45 (240.0)

7.16 (181.9)

29 (13)

31 (14)

Weight Lbs (kg)

3
3
3
3

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T3-19

Structured Wiring
Intercom System

4.1

StructuredWiringSolutions™
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Application Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

V1-T4-2
V1-T4-2
V1-T4-4
V1-T4-21

4
4
4
4

Learn
Online

4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com

V1-T4-1

4.1
4

Structured Wiring
StructuredWiringSolutions

Contents

Intercom System

Description

4

StructuredWiringSolutions
Product Selection. . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .

4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

Product Description

Application Description

Structured wiring is a
simple, affordable way
to wire a home for state-ofthe-art communications,
entertainment and security
now and for many years
to come.

●

The basic concept is that
all telephone, television,
satellite, coaxial, audio and
data communications cables
are wired in a star topology
(home run) to each room in
the home and terminate
at a central distribution
panel. This distribution
panel allows flexibility for
future modifications and/or
additions to keep pace with
a homeowner’s lifestyle
and needs.

●
●
●
●
●

Telephone
High-speed Internet
Computer networks
Web-safe Internet router
Whole-house sound
Satellite/cable TV

Wall Outlets and Basic Package

Structured wiring can also
be used as a central hub
to interconnect a security
system, home automation,
HVAC and load control,
providing a complete system
to increase the security,
comfort and convenience
for a homeowner.

4
4
4
4
4
V1-T4-2

Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com

Page
V1-T4-4
V1-T4-21

Structured Wiring
StructuredWiringSolutions

4.1

A Home with StructuredWiringSolutions Gives You Ready Control of the Latest in Computing, Audio, Video and
Communications. With the Right Components, Your Dream Home is Ready for Today’s World and Tomorrow’s Advancements.
Your Value is Ensured...and so is Your Peace of Mind

4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com

V1-T4-3

4.1
4

4

StructuredWiringSolutions

Product Selection

4
4

Structured Wiring

Packaged Products
Product Description

UPC Code

Catalog Number

ESWB100

Perfect for apartments, condos or even entry level homes. This distribution panel distributes four incoming telephone
lines to six locations, punchdown, and one incoming coax signal to four locations, passive. Installation is easy and a stylish
three-gang wall plate cover provides a professional looking finish.

782116895359

ESWB100

ESWB100P

Same as ESWB100, except punchdown for telephone is doubled for 11 locations and there is no coax distribution.
Perfect for commercial and resi applications for phone only, or for six phone locations and/or six computer locations.

782116895366

ESWB100P

4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
V1-T4-4

Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com

Structured Wiring
StructuredWiringSolutions

4.1

Video Modules
ESWV10400

Product Description

UPC Code

Catalog Number

1 x 4 coax module. 1 in, 4 out coax module with four pass-through connectors. 6-inch form factor. 1.0 lb.

782116895502

ESWV10400

4
4
4
4

ESWV10800

1 x 8 coax module. 1 in, 8 out coax module with two pass-through connectors. 6-inch form factor. 1.3 lbs.

782116895496

ESWV10800

4
4
4

ESWV10800A

1 x 8 amplified coax module. 1 in, 8 out coax module with 12 dB bi-directional amplifier and two pass-through
connectors. 6" form factor. 2.4 lbs.

782116895519

ESWV10800A

4
4
4

ESWV50800A

5 x 8 coax module. 5 in, 8 out coax module with 20 dB bi-directional amplifier, surge protection, and four pass-through
connectors, and four inputs for modulated signals. 12-inch form factor. 3 lbs.

782116895526

ESWV50800A

4
4
4

ESWV51200A

5 x 12 coax module. 5 in, 12 out coax module with 20 dB bi-directional amplifier, surge protection, and four pass-through
connectors, and four inputs for modulated signals. 12-inch form factor. 3.5 lbs.

782116895533

ESWV51200A

4
4

ESWV51600A

5 x 16 coax module. 5 in, 16 out coax module with 20 dB bi-directional amplifier, surge protection, with one direct and four
inputs for modulated signals. 12-inch form factor. 3.6 lbs.

782116895557

ESWV51600A

4
4
4

110 Volt video amplifier power supply. Power supply for all amplified video modules.

782116009671

4

ESWV110

4
4
4
4
4
4
4
4
4
4
4
Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com

V1-T4-5

4.1

StructuredWiringSolutions

Telephone Modules

4
4

Structured Wiring

Product Description

UPC Code

Catalog Number

ESWT41200P

12-port, four-line punchdown telephone module. The 12/4 punchdown telephone module has 12 110 punchdown blocks
that distribute four incoming lines to 12 locations. 6-inch form factor. 1 lb.

782116895434

ESWT41200P

ESWT40800

Eight-port, four-line telephone module. Eight RJ-45 ports support four incoming phone lines. One RJ31X port for security.
6-inch form factor. 1.0 lb.

782116895441

ESWT40800

ESWT41600

16-port, four-line telephone module. 16 RJ-45 ports support four incoming phone lines. One RJ31X port for security.
6-inch form factor. 1.25 lbs.

782116895458

ESWT41600

ESWTB48800

4 x 8 telephone breakout module. Distributes four incoming telephone lines to eight locations, RJ-45 style,
eight breakout ports, four-line pass-through. Breakout configurations: 1-2, 2-1, 3-4, 4-3.

782116894499

ESWTB48800

ESWTB801

Eight location non-bridged phone module. Eight RJ-45 jacks connected directly to eight 110 punchdown connectors,
(one-to-one) can be bridged together, great for Ethernet switches and routers.

786685255859

ESWTB801

ESWTB00

Telephone line breakout module. This module can be hung from an RJ-45 wall plate to break out and put lines 1–4
on individual center pairs so that all four lines in the RJ-45 jack are connectable to a standard RJ11 wired device.

782116895465

ESWTB00

4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
V1-T4-6

Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com

Structured Wiring
StructuredWiringSolutions

4.1

Combination Modules
ESWD40800

Product Description

UPC Code

Catalog Number

Combo 4 x 8 coax/phone distribution module (with RJ-45 patch connectors). Distributes one incoming coax TV line
to four locations (plus two pass-through) and four telephone lines to eight locations. Includes an RJ31X connection.
6-inch form factor. 1.1 lbs.

782116895472

ESWD40800

4
4
4
4

ESWD40800P

Combo 4 x 8 coax/phone distribution module (with 110 punchdown connectors). Distributes one incoming coax
TV line to four locations (plus two pass-through) and four telephone lines to eight locations. 6-inch form factor. 1.2 lbs.

782116895489

ESWD40800P

4
4
4

ESWD80800

Combo 8 x 8 passive coax/phone distribution module (with RJ-45 patch connectors). Distributes one incoming coax
TV line to eight locations (plus two pass-through) and four telephone lines to eight locations. Includes an RJ31X connection.
6-inch form factor. 1.2 lbs.

782116895380

Combo 8 x 8 active coax/phone distribution module (with RJ-45 patch connectors). Distributes one incoming coax
TV line to eight locations with built-in amplification (plus two pass-throughs) and four telephone lines to eight locations.
Includes an RJ31X connection. 6-inch form factor. 1.2 lbs.

782116895397

Combo 8 x 8 passive coax/phone distribution module (with 110 punchdown connectors). Distributes one incoming
coax TV line to eight locations (plus two pass-through) and four telephone lines to eight locations. 6-inch form factor. 1.2 lbs.

782116895373

ESWD80800

4
4
4

ESWD80800A

ESWD80800P

ESWD80800A

4
4

ESWD80800P

4
4
4

ESWD80800AP

Combo 8 x 8 active coax/phone distribution module (with 110 punchdown connectors). Distributes one incoming
coax TV line to eight locations with built-in amplification (plus two pass-throughs) and four telephone lines to eight locations.
Includes an RJ31X connection. 6-inch form factor.

782116895403

ESWD80800AP

4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com

V1-T4-7

4.1

StructuredWiringSolutions

Modules

4
4

Structured Wiring

Product Description

UPC Code

Catalog Number

ESWF001

Blank filler module. Use this blank filler module to hide cables in the panel.

782116031467

ESWF001

ESWP100

Blank patch module. Use this blank patch module to custom design a zone. The blank patch module accepts any
configuration of CAT5e, RG6 coax or fiber optic inserts. Labeling areas allow you to identify the connections and what
rooms they represent. 6-inch form factor.

782116895427

ESWP100

ESWMP300

Three-zone patch module. 12 connection ports (two CAT5 and two coax per zone). 6-inch form factor. 0.8 lbs.
Allows for many room locations (wall plates) to be terminated cleanly and professionally without having to add
expensive service modules. Active wall plates can be patch corded to data, voice or video modules as needed
without complication or added expense. Outlet locations can be permanently labeled for easy consumer plug n’ play,
and changing applications and life styles.

782116895410

ESWMP300

ESWM300

Triple channel modulator module. Used for creating in-home television channels for viewing from any TV in the home.
Signals from three different audio/video sources such as TV, VCR, DVD, DBS, satellite TV and security cameras may be
identified and displayed by any television. 6-inch form factor. 2.1 lbs.

782116895557

ESWM300

ESWMOD1

One-channel standalone modulator. Distributes one video signal (camera, DVD, SATV, CATV) to any television
in the house.

782116895564

ESWMOD1

ESWMOD1

Three-channel standalone modulator. Distributes three video signals (camera, DVD, SATV, CATV) to any television
in the house.

782116895571

ESWMOD1

ESWN100

Four-port 10/100 wireless firewall router. Distributes DSL/Broadband service up to four computer locations.
Also provides wireless connectivity.

782116895342

ESWN100

V1-T4-8

Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com

4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

Structured Wiring
StructuredWiringSolutions

4.1

Modules, continued
ESWN400

Product Description

UPC Code

Catalog Number

DSL or cable router with four-port 10/100M fast ethernet switch. Built-in NAT Firewall. 6-inch form factor.

782116895588

ESWN400

4
4
4
4

ESWN800

Eight-port 10/100M DSL or cable router. Built-in NAT and parental controls.

786685245768

4

ESWN800

4
ESWMS100

Product shelf 14 x 4 inches. Can be mounted anywhere in the panel. Allows for third-party products to be mounted
in the panel. (Modems, power strip, etc.)

782116894437

ESWMS100

ESWMS200

Service shelf 14 x 8 inches. Can be mounted anywhere in the panel. Designed as a work shelf for the installer.

782116977192

ESWMS200

4
4
4
4

ESWMS300

4
12-inch blank mounting shelf. Stand-off hole placements for Ademco, First Alert, Caddx, DSC,
and Electronics Line security panels.

782116049318

ESWMS300

4
4

ESWMSC300

12-inch blank mounting shelf cover. Designed to fit over the ESWMS300.

782116049325

ESWMSC300

4
4
4

ESWV100

Camera with IR emitters. 1/4-inch color camera with IR emitters for night-time viewing. Includes mounting bracket.
Does not include power supply.

782116977178

ESWV100

4
4

ESWV200

4
Dome camera. 3.6 mm color dome camera. Can be flush or surface mounted. Does not include the power supply.

782116977185

ESWV200

4
4

ESWVQ4

Four-position video processor. Allows viewing of four cameras on one channel. Includes remote for easy access.

786685245775

4

ESWVQ4

4
4
4
20-pack of molly rivets and plungers. Use for connecting individual modules to the install can.

782116103126

4

ESWVRIV

4
4
4
4
Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com

V1-T4-9

4.1

StructuredWiringSolutions

Audio System Components

4
4

Structured Wiring

Product Description

UPC Code

Catalog Number

75-watt volume control. For analog audio systems.
White

782116895328

ESWA75W

Almond

782116895335

ESWA75A

ESWA6500SC

6.5-inch standard round ceiling speaker. 3/4-inch Mylar swivel tweeter, 80 watts.

782116894413

ESWA6500SC

ESWA6550SC

6.5-inch high-end round ceiling speaker (set of two). In-ceiling, 6.5-inch poly woofer, 1-inch swivel tweeter.
Surround sound capable. Suitable for all audio systems.

782116895304

ESWA6550SC

ESWA0800SC

8-inch round ceiling speaker. 1-inch cloth swivel tweeter, 120 watts.

782116894420

ESWA0800SC

ESWA6500SW

6.5-inch in-wall speakers (set of two). In-wall, 6.5-inch poly woofer, 0.75-inch tweeter. Surround sound capable.
Suitable for all audio systems.

782116895311

ESWA6500SW

ESWA5500OW

5.5-inch outdoor speakers (set of two). Outdoor, 5.5-inch poly woofer, 0.75-inch tweeter. Surround sound capable.
Suitable for all audio systems.
White

782113965918

ESWA5500OW

Black

782113965925

ESWA5500OB

ESWA65DVC

6.5-inch round dual voice coil speaker. Dual 1/2-inch Mylar tweeters, 80 watts. Suitable for small room installations.

786685271491

ESWA65DVC

ESWA65ABD

6.5-inch round A-BUS direct ceiling speaker. Built-in A-BUS amplification. Shipped with multi-function multi-source
remote with cradle.

786685285092

ESWA65ABD

ESWA55OABDW

5.5-inch A-BUS direct outdoor speakers. Weather resistant, UV protected. Outdoor speakers with built-in
Class D A-BUS amplifier.

786685366401

ESWA55OABDW

ESWA6R

6.5-inch rough-in ring. Designed to fit models ESWA6500SC, ESWA6550SC, ESWA65DVC and ESWA65DVC.

786685366425

ESWA6R

ESWA8R

8-inch rough-in ring. Designed to fit model ESWA800SC.

786685366418

ESWA8R

ESWA75W

4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
V1-T4-10

Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com

Structured Wiring
StructuredWiringSolutions

4.1

A-BUS Products
Product Description
ESWAM600C

UPC Code

A-BUS audio distribution module (6-inch form factor). The Zone 6 audio distribution module distributes CAT5 audio to six 782116153084
locations. Can be cascaded to one or two additional modules for 12 or 18 locations.

Catalog Number
ESWAM600C

4
4
4

ESWAM800

Eight-location audio distribution module. Distributes one signal to eight stereo locations via traditional speaker
wire up to 16 gauge.

786685015194

ESWAM800

4
4
4

ESWAMK4801C

4 Source, 8 zone A-BUS audio kit. Kit includes power supply, (4) source input plates (ESWA7500CW)
and (1) ESWA300 remote.

786685401331

ESWAMK4801C

4
4
4

ESWAM4801C

4 Source, 8 zone A-BUS audio module. Audio module only with power supply.

786685401317

ESWAM4801C

4
4
4
4

ESWA200CW

ESWA300CW

ESWA400CW

A-BUS volume control. The volume control is the down line amplifier that converts the distributed audio signal back to an
analog signal that is then distributed over speaker wire to in-wall/ceiling speakers.
White

786685017297

ESWA200CW

Almond

786685017280

ESWA200CA

4
4
4

A-BUS volume control with “IR” input option. The IR allows the entertainment center's wireless remote to be used in
rooms that have this feature. Decora faceplate not included.
White

782116153121

ESWA300CW

Almond

782116153138

ESWA300CA

4
4
4

A-BUS two-button volume control with “IR” input option. Decora faceplate not included.
White.

782116978038

ESWA400CW

Almond

782116978045

ESWA400CA

4
4
4

ESWA4500CW

4

A-BUS four-position backlit multi-source volume control with “IR” input option. Specifically designed for use
with the ESWAM4800 multi-source module. Decora faceplate not included.
White.

782116894444

ESWA4500CW

Almond

782116894451

ESWA4500CA

4
4
4

ESWA701CW
A-BUS local input plate. Overrides the whole house music and allows a local source such as MP3 player and TVs
to play in the zone or room.
White

786685359197

ESWA701CW

Almond

786685359205

ESWA701CA

4
4
4
4

Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com

V1-T4-11

4.1

StructuredWiringSolutions

A-BUS Products, continued

4

Product Description

UPC Code

Catalog Number

Source input plate for multi-source A-BUS audio A-BUS. Provides one input and pass-through for audio equipment.
Input for one IR emitter and one relay output.

786685401324

ESWA7500CW

ESWAP

A-BUS modules power supply

782116978021

ESWAP

ESWA100CR

A-BUS four-button remote control. For use with all A-BUS volume controls with IR inputs.
Controls volume and source inputs.

782116894475

ESWA100CR

ESWA300CR

A-BUS IR remote control. For use with all A-BUS volume controls. Single and multi-source operation. Shipped with
mounting cradle.

786685362175

ESWA300CR

ESWA500C

A-BUS component interface unit. The ESWA500C is used when the customer’s amplifier does not have an A-BUS CAT5e
output built in. RCA connectors are run from the amplifier to the ESWA500C, and then a CAT5e homerun is made to the
ESWAM600C in the main distribution panel.

782116153145

ESWA500C

ESWEM100

A-BUS single lead “IR” emitter.

782116940189

ESWEM100

ESWEM200

A-BUS dual lead “IR” emitter.

782116940196

ESWEM200

ESWABI100

A-BUS two-door intercom module. This module is the core of the incom system. Includes two-door station outputs
and eight room locations.

782116940202

ESWABI100

ESWABI200

A-BUS mini master room keypad.
White

782116940219

ESWABI200

Almond

786685138572

ESWABI200A

A-BUS control center (master keypad).
White

782116940226

ESWABI300

Almond

786685138589

ESWABI300A

4
4

Structured Wiring

4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4

ESWABI300

4
4
4
4
V1-T4-12

Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com

Structured Wiring
StructuredWiringSolutions

4.1

A-BUS Products, continued
ESWABI200PA

Product Description

UPC Code

Catalog Number

Intercom outdoor keypad. Weather resistant UV protected, aluminum color.

786685242262

ESWABI200PA

4
4
4
4

ESWABI200PB

Intercom outdoor keypad. Weather resistant UV protected, brushed brass color.

786685242279

ESWABI200PB

4
4
4

ESWABI400

A-BUS door station.
White

782116940233

ESWABI400

4
4
4

ESWABI500A

Front door cover plate. Weather resistant UV protected, aluminum color.

786685242262

ESWABI500A

4
4
4

ESWABI500B

Front door cover plate. Weather resistant UV protected, brushed brass color.

786685242279

ESWABI500B

4
4
4
4

ESWABIK311

Intercom kit. Kit includes one master keypad, three mini master keypads, one door station and one intercom module.
White keypad

782116940240

ESWABIK311

Almond keypad

786685138725

ESWABIK311A

4
4
4
4
4
4
4
4
4
4
4
4
4

Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com

V1-T4-13

4.1

StructuredWiringSolutions

Enclosures

4
4

Structured Wiring

Product Description

UPC Code

Catalog Number

ESWI1200

12 x 14.5 x 4 inch install can. Allows room for three 6-inch modules. Panel includes a
power receptacle and grounding bar.

782116469185

ESWI1200

ESWI1800

18 x 14.5 x 4 inch install can with 110V power. Allows room for five 6-inch modules.
Panel includes a power receptacle and grounding bar.

782116904808

ESWI1800

ESWI2400

24 x 14.5 x 4 inch install can with 110V power. Allows room for seven 6-inch modules.
Panel includes a power receptacle and grounding bar.

782116904822

ESWI2400

ESWI3600

36 x 14.5 x 4 inch install can with 110V power. Allows room for (11) 6-inch modules.
Panel includes a power receptacle and grounding bar.

782116904846

ESWI3600

ESWI5400

54 x 14.5 x 4 inch install can with 110V power. Allows room for (17) 6-inch modules.
Panel includes a power receptacle and grounding bar.

78211649284

ESWI5400

4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
V1-T4-14

Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com

Structured Wiring
StructuredWiringSolutions

4.1

Enclosures, continued
ESWFDB24

Product Description

UPC Code

Catalog Number

24-inch NEMA-3R D-marc box with plywood back. Meets the new SBC and Verizon specifications
for outdoor fiber optic installations. Includes a power receptacle and grounding bar.

782116906581

ESWFDB24

4
4
4
4

ESWFDB32

32-inch NEMA-3R D-marc box with plywood back. Meets the new SBC and Verizon specifications
for outdoor fiber optic installations. Includes a power receptacle and grounding bar.

782116906598

ESWFDB32

4
4
4
4
4

Covers
ESWC1200

Product Description

UPC Code

Catalog Number

17 x 14 inch metal cover for install can ESWI1200. Includes venting for protection
of installed electronic equipment.

782116469192

ESWC1200

4
4
4
4

ESWC1800

17 x 20 inch metal cover for install can ESWI1800. Includes venting for protection
of installed electronic equipment.

782116904815

ESWC1800

4
4
4

ESWC2400

17 x 26 inch metal cover for install can ESWI2400. Includes venting for protection
of installed electronic equipment.

782116904839

ESWC2400

4
4
4
4

ESWC3600

17 x 38 inch metal cover for install can ESWI3600. Includes venting for protection
of installed electronic equipment.

782116904853

ESWC3600

4
4
4
4
4
4
4
4
4
4

Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com

V1-T4-15

4.1

StructuredWiringSolutions

Covers, continued

4
4

Structured Wiring

Product Description

UPC Code

Catalog Number

ESWC5400

17 x 56 inch metal cover for install can ESWI5400. Includes venting for protection
of installed electronic equipment.

782116469291

ESWC5400

ESWC1800H

17 x 20 inch hinged cover for install can ESWI1800. One cover to a carton.

786685015163

ESWC1800H

ESWC2400H

17 x 26 inch hinged cover for install can ESWI2400. One cover to a carton.

786685015170

ESWC2400H

ESWC3600H

17 x 38 inch hinged cover for install can ESWI3600. One cover to a carton.

786685015187

ESWC3600H

ESWC5400H

17 x 56 inch hinged cover for install can ESWI5400. One cover to a carton.

786685015132

ESWC5400H

4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
V1-T4-16

Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com

Structured Wiring
StructuredWiringSolutions

4.1

Covers, continued
ESWC1200P

Product Description

UPC Code

Catalog Number

17 x 14 inch clear plastic cover for install can ESWI1200. Includes venting for protection of installed electronic
equipment.

782116469208

ESWC1200P

4
4
4
4

ESWC1800P

17 x 20 inch clear plastic cover for install can ESWI1800. Includes venting for protection of installed electronic
equipment.

782116630103

ESWC1800P

4
4
4
4

ESWC2400P

17 x 26 inch clear plastic cover for install can ESWI2400. Includes venting for protection of installed electronic
equipment.

782116630110

ESWC2400P

4
4
4
4

ESWC3600P

17 x 38 inch clear plastic cover for install can ESWI3600. Includes venting for protection of installed electronic
equipment.

782116630127

ESWC3600P

4
4
4
4
4

ESWC3600P

17 x 56 inch clear plastic cover for install can ESWI5400. Includes venting for protection of installed electronic
equipment.

782116630134

ESWC5400P

4
4
4
4
4
4
4
4
4
4
4
4
4

Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com

V1-T4-17

4.1
ESWR100CW

4
4
4

ESWR100TW5W

4
4
4

StructuredWiringSolutions

Wall Plates

4
4

Structured Wiring

ESWR100TW

4

Product Description

UPC Code

Catalog Number

One-port wall outlet. One coax TV connection (RG6).
White

782116894703

ESWR100CW

Almond

782116894680

ESWR100CA

Ivory

782116894697

ESWR100CI

Wall hanging telephone wall plate. One CAT5e telephone/data connector.
White

782116894383

ESWR100TW5W

Almond

782116894369

ESWR100TW5A

Ivory

782116894376

ESWR100TW5I

One-port wall outlet. One RJ11 telephone connection (CAT3 rated).
White

782116894765

ESWR100TW

Almond

782116894741

ESWR100TA

Ivory

782116894758

ESWR100TI

One-port wall hanging outlet. One RJ11 telephone connection (CAT3 rated).
White

782116894796

ESWR100TWW

Almond

782116894772

ESWR100TWA

Ivory

782116894789

ESWR100TWI

One-port wall outlet. One RJ45 telephone/data connection (CAT5e rated).
White

782116894734

ESWR100T5W

Almond

782116894710

ESWR100T5A

Ivory

782116894727

ESWR100T5I

Two-port multimedia wall outlet. Telephone/data connection (CAT5e), one coax TV connection (RG6).
White

782116894826

ESWR200W

Almond

782116894802

ESWR200A

Ivory

782116894819

ESWR200I

Three-port multimedia wall outlet. One telephone/data connection (CAT5e), two coax TV connections (RG6).
White

782116894857

ESWR300W

Almond

782116894833

ESWR300A

Ivory

782116894840

ESWR300I

Four-port multimedia wall outlet. Two telephone/data connections (CAT5e), two coax TV connections (RG6).
White

782116894888

ESWR400W

Almond

782116894864

ESWR400A

Ivory

782116894871

ESWR400I

4
4

ESWR100TWW

4
4
4

ESWR100T5W

4
4
4

ESWR200W

4
4
4

ESWR300W

4
4
4

ESWR400W

4
4
4
4
4
4
4
V1-T4-18

Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com

Structured Wiring
StructuredWiringSolutions

4.1

Wall Plates, continued
ESWR600W

ESWR110W

Product Description

UPC Code

Catalog Number

Six-port multimedia wall outlet. Two telephone/data connections (CAT5e), two blanks
(may be populated with CAT5e, coax, or fiber optic connectors), two coax TV connections (RG6),
White

782116894918

ESWR600W

Almond

782116894895

ESWR600A

Ivory

782116894901

ESWR600I

One-port blank receptacle. (Blank face plates.)
White

782116961924

ESWR110W

Almond

782116894925

ESWR110A

Ivory

782116894932

ESWR110I

4
4
4
4
4
4
4

ESWR110W

One-port blank oversized plate.
White

786685242224

ESWRO110W

Almond

786685242231

ESWRO110A

4
4
4

ESWR210W

ESWR210W

ESWR310W

ESWR410W

ESWR610W

Two-port blank receptacle. (Blank face plates.)
White

782116894970

ESWR210W

Almond

782116894956

ESWR210A

Ivory

782116894963

ESWR210I

4
4
4

Two-port blank oversized plate.
White

786685242248

ESWRO210W

Almond

786685242255

ESWRO210A

4
4
4

Three-port blank receptacle. (Blank face plates.)
White

782116895007

ESWR310W

Almond

782116894987

ESWR310A

Ivory

782116894994

ESWR310I

Four-port blank receptacle. (Blank face plates.)
White

782116895038

ESWR410W

Almond

782116895014

ESWR410A

Ivory

782116895021

ESWR410I

Six-port blank receptacle. (Blank face plates.)
White

782116895069

ESWR610W

Almond

782116895045

ESWR610A

Ivory

782116895052

ESWR610I

4
4
4
4
4
4
4
4
4
4
4
4
4
4

Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com

V1-T4-19

4.1

Structured Wiring
StructuredWiringSolutions

Inserts

4

Product Description

UPC Code

Catalog Number

Blank inserts for distribution panel. Sold in 12 pack.
Yellow

782116895106

ESWBLY

4

Red

782116895083

ESWBLR

4

Blue

782116895076

ESWBLB

White

782116895090

ESWBLW

RG6 coax connectors for distribution panel. Sold in 12 pack.
Yellow

782116895229

ESWMLC

RJ45, CAT5e rated connectors for distribution panel. Sold in 12 pack.
Blue

782116895212

ESWML5B

CAT5e bezels for distribution panel. Sold in 12 pack.
Orange

782116469215

ESWML5O

CAT5e bezels for distribution panel. Sold in 12 pack.
Blue

782116895113

ESWBZ5

Blank insert for receptacles. Sold in 12 pack.
White

782116895144

ESWINSBLW

Almond

782116895120

ESWINSBLA

Ivory

782116895137

ESWINSBLI

RJ11 wall plate insert. Sold in 12 pack.
White

782116981335

ESWINS11W

Almond

782116981328

ESWINS11A

Ivory

782116981311

ESWINS11I

CAT5e insert for receptacles. Sold in 12 pack.
White

782116895175

ESWINS5W

Almond

782116895151

ESWINS5A

4

Ivory

782116895168

ESWINS5I

4

Blue

782116981342

ESWINS5B

Orange

782116981359

ESWINS5O

4

CAT6 insert for receptacles and patch modules. Sold in 12 pack.
White

786685410609

ESWINS6W

4

Almond

786685410593

ESWINS6A

Ivory

786685410616

ESWINS6I

4

RG6 coax inserts for receptacles. Sold in 12 pack.
White

782116895205

ESWINSCW

4

Almond

782116895182

ESWINSCA

Ivory

782116895199

ESWINSCI

4

4

ESWBLY

ESWMLC

4
4
4

ESWML5B

4
4
4

ESWML5O

4
4
4

ESWBZ5

4
4
4

ESWINSBLW

4
4
4
4
4

4
4
V1-T4-20

Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com

Structured Wiring
StructuredWiringSolutions

4.1

Accessories

4
4

Patch Cords
ESWPT308B

Product Description

UPC Code

Catalog Number

Two pair, CAT3 telephone patch cord. Blue
8 inches

4

782116895267

ESWPT308B

24 inches

782116895274

ESWPT324B

4

36 inches

782116894390

ESWPT336B

48 inches

782116469239

ESWPT348B

4
4
4

ESWPT508B

Four pair, CAT5e telephone patch cord. Blue
8 inches

782116895281

ESWPT508B

24 inches

782116895298

ESWPT524B

36 inches

782116894406

ESWPT536B

48 inches

782116469246

ESWPT548B

4
4
4
4

ESWPT524O

CAT5e telephone patch cord. Orange
24 inches

782116469253

ESWPT524O

36 inches

782116469260

ESWPT536O

48 inches

782116469277

ESWPT548O

4
4
4
4

ESWPC08

4

RG6-rated mini digital cable. Yellow
8 inches

782116895236

ESWPC08

24 inches

782116895243

ESWPC24

36 inches

782116895250

ESWPC36

48 inches

782116469222

ESWPC48

4
4
4
4
4
4
4
4
4
4
4
4
4
4

Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com

V1-T4-21

Metering Products
Group Metering and
Meter Breaker Family

5.1

Single Meter Sockets
Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5.2

5.4

5.7

5.10

V1-T5-29

V1-T5-34

V1-T5-35

V1-T5-37
V1-T5-39
V1-T5-48
V1-T5-59
V1-T5-65
V1-T5-75
V1-T5-83
V1-T5-86
V1-T5-87

Group Metering
Systems for Residential and Commercial Applications . . . . . . . . . . . .
Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type CCV 120/240V Tenant Main Circuit Breaker . . . . . . . . . . . . . . . .
Type CV 120/240V Tenant Main Circuit Breaker . . . . . . . . . . . . . . . . .
Meter Packs—1MP, 1MM and 3MM Main Tenant Circuit Breakers . .
Main Service Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Surge Metering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Residential Meter Stacks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1MP, 1MM and 3MM Main Tenant Circuit Breakers . . . . . . . . . . . . . .
Phase Balanced Stack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Commercial Meter Stack Modules . . . . . . . . . . . . . . . . . . . . . . . . . . .
35MM, 37MM, 35SS and 37SS Main Tenant Circuit Breakers . . . . . .

5
5
5
5
5

Meter Breakers
Residential Meter Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Non-EUSERC Combination Service Entrance Devices 100–200A Styles
Meets EUSERC Requirements Service Entrance Devices 100–225A.
West Coast All-In-One Design. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mechanical Interlock Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
House Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Commercial Safety Sockets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CH Style Renovation Solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Aluminum Meter Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5

5

Communications Grounding Device (NEC 250.94)
Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5.9

V1-T5-27

Mechanical Lugs
Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5.8

V1-T5-25

Accessories and Cross-Reference
Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5
5

Residential Pedestals
Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5.6

V1-T5-18

Instrument Rated Sockets
Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5.5

V1-T5-10

Multiple Position Horizontal Ganged Sockets
Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5
5

Commercial Lever Bypass Sockets
Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5.3

V1-T5-2

V1-T5-88
V1-T5-90
V1-T5-95
V1-T5-96
V1-T5-98
V1-T5-101
V1-T5-115
V1-T5-116
V1-T5-125
V1-T5-126
V1-T5-127
V1-T5-134

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

Learn
Online

5
5
5
Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-1

5.1
5

Metering Products
Single Meter Sockets

Contents

Single Meter Sockets

Description

5

Features and Benefits . . . . . . . . . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5
5
5
5
5
5
5
5
5
5
5
5
5
5

Product Description
Single-Phase Three-Wire and Three-Phase Four-Wire 600 Vac
Single Meter Sockets
All Eaton sockets are rated
600 Vac maximum and either
100, 200 or 320A continuous.
All have a minimum shortcircuit rating of 10,000 rms
symmetrical amperes
(watthour meter is not
included in rating).

All single meter sockets are
UL labeled and are supplied in
surface mounted outdoor
enclosures. Confirm local
utility acceptance prior to
order entry.

5
5
5
5
5
5
5
5
5
5
5
5
5
5
V1-T5-2

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Page
V1-T5-3
V1-T5-3
V1-T5-4
V1-T5-8

Metering Products
Single Meter Sockets

5.1

Features and Benefits

5
5

Single Meter Sockets

5

Features

Benefits

Block assembly base exceeds 400 in-lbs of torque

Provides durability under the most extreme installation circumstances

One-piece, die-run enclosure

Eliminates tampering and extends product life

High visibility Eaton name embossed on cover

Company identity and brand preference

Knockouts are installer friendly

Labor savings, less time needed for removing knockouts

Oversized 7/8-inch diameter, heavy-duty, steel lug screws

Stronger connection component facilitates a reliable wire termination

Slide-nuts are captive

Allow for ease in installation of conductors and eliminates lost components

Horn bypass kit is field installable by changing out slide nut

Less inventory required and field modifications are simple

Integral triplex or quadplex ground extruded in neutral lug

One piece for terminating incoming/outgoing neutral conductors, which increases integrity of connections

100% plated bridge with 4-point mounting

Zinc chromate plated to provide superior corrosion resistance

5
5
5
5
5

kAIC rating

Tested and UL listed up to 200 kAIC rating with specified overcurrent protection devices

Provides a complete Eaton residential solution

Adding meter sockets to the already existing (loadcenter, surge, breakers, generators and AC disconnect) product lines that we already
provide, makes Eaton a one-stop shop for our customers residential and light commercial needs

Copper-plated alloy jaws with reinforcing spring

Steel reinforcing springs used in all socket jaws to maintain electrical connections

5
5

Catalog Number Selection

5
5

Single Meter Sockets RS Group

UT RS 2 0 2 B CH
Note: The “U” prefix is always used first followed by
other prefixes required in alphabetical order.
Standard Prefixes
A = Aluminum enclosure
B = Barrel lock provision, for an exposed INNER-TITE® or Brooks barrel lock;
unit includes an internal lock receiver bracket
F = Barrel Lock with guard provision, for a lock guard INNER-TITE or Brooks
barrel lock; unit includes an internal lock receiver bracket
G = Grounded fifth terminal (9 o’clock position)
H = Horn bypass
I = Inhibitor installed in wire connectors
M = Temporary meter cover (waxed cardboard)
N = No sealing ring (applies only to ring style sockets)
R = Ring style socket
S = Aluminum screw type sealing ring (applies only to ring style sockets)
T = Grounding connector (#14–#2 Cu) for triplex ground
TT = Two grounding connectors (#14–#2 Cu) for quadplex ground
U = UL Underwriters Laboratories label
Z = 5/16-inch hex head connector screw in place of slotted (100A only)

RS
=
2R-6R =
2H-6H =
H
=

5

Product Group
Residential service, single position
Residential service, multiple position
Commercial or residential service, multiple position
Commercial or residential service, single position

5
5

Standard Suffixes
A = Solid top
B = Small hub opening
C = Small hub closing plate mounted
L = 1.25-inch (31.8 mm) hub mounted
M = 1.50-inch (38.1 mm) hub mounted
N = 2.00-inch (50.8 mm) hub mounted
P = 2.50-inch (63.5 mm) hub mounted
T = Large hub opening hub
U = Large hub cover plate hub mounted
V = 2.50-inch (63.5 mm) large hub mounted
Q = 3.00-inch (76.2 mm) large hub mounted
R = 3.50-inch (88.9 mm) large hub mounted
S = 4.00-inch (101.6 mm) large hub mounted
Z = Large to small hub adapter mounted

5
5
5
5
5
5

Maximum Conductor (Line and Load)
0 = 0.38-inch stud connectors
1 = #2/0 connectors
2 = #250 kcmil connectors
3 = #350 kcmil connectors

5
5
5

Service Design
0 = Overhead
1 = Combination overhead/underground
2 = Underground, side wired
3 = Combination overhead/underground, side wired

5
5

Ampere Rating
1 = 100A
2 = 200A
5 = 150A

5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-3

5.1
5
5

Metering Products
Single Meter Sockets

Product Selection
URS212ACH

Residential Ringless Type Cover

5

Ampere
Rating

Jaws

Service

Bypass

Line

Load

Opening, Hub or
Closure Plate

Catalog Number

5

200

4

UG

—

3/8-inch studs

3/8-inch studs

Solid top

UTRS240ACH

5

200

4

OH/UG

—

3/8-inch studs

3/8-inch studs

3-5/16 hub cover plate

UTRS2303CCH

200

4

UG

—

#8–350 kcmil

#8–350 kcmil

Solid top

UTRS223ACH

200

4

UG

—

3/8-inch studs

3/8-inch studs

Solid top

UTRS220ACH

200

4

OH/UG

—

#8–350 kcmil

#8–350 kcmil

3-5/16 cover plate

UTRS213CFLCH

5

200

4

OH/UG

—

#8–350 kcmil

#8–350 kcmil

3-5/16 hub cover plate

UTRS213CEPCH

5

200

4

OH/UG

—

#6–350 kcmil

#6–350 kcmil

3-5/16 hub cover plate

UGTRS213CE

200

4

OH/UG

—

#6–350 kcmil

#6–350 kcmil

3-5/16 hub cover plate

UTRS213CE

5

200

4

OH/UG

—

#6–350 kcmil

#6–350 kcmil

3-5/16 hub opening

UATRS213BCH

200

4

OH/UG

—

#6–350 kcmil

#6–350 kcmil

3-5/16 hub opening

URS213BCH

5

200

4

OH/UG

—

#6–350 kcmil

#6–350 kcmil

3-5/16 hub opening

UTRS213BE

5

200

4

UG

—

#8–350 kcmil

#8–350 kcmil

Solid top

UTRS213AFLCH

200

4

UG

—

#8–350 kcmil

#8–350 kcmil

Solid top

UTRS213ACH

5

200

4

OH/UG

Horn

#8–350 kcmil

#8–350 kcmil

3-5/16 hub opening

UTRS2138BCH

200

4

OH/UG

—

#8–250 kcmil

#8–250 kcmil

Solid top

UTRS212ACH

5

200

4

OH/UG

—

#8–250 kcmil

#8–250 kcmil

3-5/16 cover plate

UTRS212CCH

5

Connections

200

4

OH/UG

—

#8–250 kcmil

#8–250 kcmil

3-5/16 cover plate

UTRS212CFLCH

200

4

OH/UG

—

#8–250 kcmil

#8–250 kcmil

3-5/16 hub opening

UTRS212BCH

5

200

4

OH

—

#8–250 kcmil

#8–250 kcmil

2-inch bolt-on hub

UTRS202NCH

200

4

OH

—

#8–250 kcmil

#8–250 kcmil

Small hub opening

UATRS202BFLCH 1

5

200

4

OH/UG

—

#8–250 kcmil

#8–250 kcmil

3-5/16 cover plate

UTRS232CCH

200

4

OH

—

#8–2/0 cu/al

#8–2/0 cu/al

3-5/16 hub opening

UTRS202BCH

5

200

4

OH/UG

—

#8–250 kcmil

#8–250 kcmil

Solid top

URS212ACH

5

200

4

OH

—

#8–250 kcmil

#8–250 kcmil

2-inch bolt-on hub

URS202NCH

200

5

OH

Horn

#8–250 kcmil

#8–250 kcmil

3-5/16 hub opening

URS202BDQCH

200

4

OH/UG

Horn

#8–350 kcmil

#8–350 kcmil

3-5/16 hub cover plate

UFHTRS213CCH 2

200

4

OH/UG

Horn

#8–350 kcmil

#8–350 kcmil

3-5/16 hub opening

UHTTRS213BCH

5

200

4

OH/UG

Horn

#8–350 kcmil

#8–350 kcmil

3-5/16 hub cover plate

UHTTRS213CCH

5

200

4

OH

Horn

#8–250 kcmil

#8–250 kcmil

3-5/16 hub opening

UHTTRS202BCH

200

5

OH/UG

Horn

#8–350 kcmil

#8–350 kcmil

3-5/16 hub cover plate

UHTRS233CCH

5

200

4

UG

Horn

#8–350 kcmil

#8–350 kcmil

Solid top

UHTRS223ARHCH

200

4

UG

Horn

#8–350 kcmil

#8–350 kcmil

Solid top

UFHTRS223ACH

5

200

5

UG

Horn

#8–350 kcmil

#8–350 kcmil

Solid top

UGHTRS223ACH

5

200

4

UG

Horn

#8–350 kcmil

#8–350 kcmil

Solid top

UHTTRS223ACH

200

4

UG

Horn

#8–350 kcmil

#8–350 kcmil

Solid top

UHTRS223ACH

5

200

4

OH/UG

Horn

#6–350 kcmil

#6–350 kcmil

3-5/16 hub opening

UHTRS213CE

200

4

OH/UG

Horn

#6–350 kcmil

#6–350 kcmil

3-5/16 hub opening

UHTRS213BE

5

200

4

OH/UG

Horn

#8–350 kcmil

#8–350 kcmil

Solid top

UHTRS213AE

200

4

OH

Horn

#8–350 kcmil

#8–350 kcmil

3-5/16 hub opening

UHTRS203BCH

200

4

OH

Horn

#8–250 kcmil

#8–250 kcmil

3-5/16 hub opening

UHTRS202BCH

200

4

OH/UG

None

#8–250 kcmil

#8–250 kcmil

2-inch bolt-on hub

URS202NPECCH 3

5

5

5
5

Notes
1 Aluminum enclosure.
2 Barrel lock.
3 PEC approved.

5
5

For dimensions, see Pages V1-T5-8 and V1-T5-9.

V1-T5-4

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

5.1

Metering Products
Single Meter Sockets

Residential Ringless Type Cover, continued
Connections

Ampere
Rating

Jaws

Service

Bypass

Line

200

4

OH/UG

Horn

#8–350 kcmil

200

4

OH/UG

Horn

200

5

OH/UG

200

5

OH/UG

5

Load

Opening, Hub or
Closure Plate

Catalog Number

#8–350 kcmil

Solid top

UHIRS223ACVCH

#8–350 kcmil

#8–350 kcmil

3-5/16 hub opening

UHIRS213BCVCH

—

#6–350 kcmil

#6–350 kcmil

Closure plate

UGTRS213CE

—

#6–350 kcmil

#6–350 kcmil

Hub opening

UGTRS213BE

200

5

OH/UG

Horn

#6–350 kcmil

#6–350 kcmil

Closure plate

786685217918

200

5

OH/UG

Horn

#6–350 kcmil

#6–350 kcmil

3-5/16 hub opening

UGHTRS213BE

200

5

OH/UG

Horn

#8–250 kcmil

#8–250 kcmil

3-5/16 hub cover plate

UGHRS212CKCCH

200

4

OH

—

#8–250 kcmil

#8–250 kcmil

3-5/16 hub opening

UFTRS202BCH

5
5
5
5
5
5

200

4

OH

Horn

#8–250 kcmil

#8–250 kcmil

3-5/16 hub opening

UFHTRS202BCH

200

4

UG

Horn

#8–350 kcmil

#8–350 kcmil

Solid top

UBHTRS223ARHCH

200

4

UG

Horn

#8–350 kcmil

#8–350 kcmil

Solid top

UBHRS223ACH

200

4

OH

Horn

#8–250 kcmil

#8–250 kcmil

3-5/16 hub cover plate

UBHRS202BCH

200

4

OH/UG

—

#8–350 kcmil

#8–350 kcmil

3-5/16 hub opening

UATRS213CFLCH

5

200

4

OH/UG

Horn

#8–350 kcmil

#8–350 kcmil

3-5/16 hub cover plate

UAHTRS233CSHCH

200

4

UG

Horn

#8–350 kcmil

#8–350 kcmil

Solid top

UAHTRS223AFLCH

200

4

OH

Horn

#8–250 kcmil

#8–250 kcmil

3-5/16 hub opening

UAHTRS202BFLCH

200

4

OH/UG

—

#8–350 kcmil

#8–350 kcmil

3-5/16 hub closure plate

U92197CCCPLCH

200

4

OH/UG

—

#8–350 kcmil

#8–350 kcmil

3-5/16 hub closure plate

1009928CH

200

4

OH/UG

Horn

#8–250 kcmil

#8–250 kcmil

Solid top

1009874ACH

200

4

UG

—

3/8-inch studs

3/8-inch studs

Solid top

1009046CH

200

4

UG

Horn

#8–350 kcmil

#8–350 kcmil

Solid top

1008941CH

200

4

UG

Horn

#8–350 kcmil

#8–350 kcmil

Solid top

1008940CH

200

4

UG

Horn

#8–350 kcmil

#8–350 kcmil

Solid top

1008827CH

200

4

UG

Horn

#8–350 kcmil

#8–350 kcmil

Solid top

1008819CH

200

4

UG

Horn

#8–350 kcmil

#8–350 kcmil

Solid top

1008717CH

200

4

UG

—

#8–350 kcmil

#8–350 kcmil

Solid top

1008617CH

200

4

OH/UG

Horn

#8–350 kcmil

#8–350 kcmil

3-5/16 hub opening

1007817CH

200

4

OH

Horn

#8–250 kcmil

#8–250 kcmil

3-5/16 hub opening

1007699CH

200

4

OH

Horn

#8–250 kcmil

#8–250 kcmil

3-5/16 hub opening

1007665CH

200

4

UG

Horn

#8–350 kcmil

#8–350 kcmil

Solid top

1007588CH

200

4

OH/UG

—

3/8-inch studs

3/8-inch studs

3-5/16 hub opening

1007448ACH

200

4

UG

Horn

#8–350 kcmil

#8–350 kcmil

Solid top

1004884ARHCH 1

200

4

UG

Horn

#8–350 kcmil

#8–350 kcmil

Solid top

1004884ACH

200

4

OH/UG

—

#8–#250 kcmil

#8–#250 kcmil

3-5/16 hub cover plate

1004710ECH

200

4

OH

—

N/A

N/A

N/A

1004709DCH

200

4

OH

Horn

#8–#250 kcmil

#8–#250 kcmil

2-inch bolt-on hubs

1004455BCH

200

4

OH

Horn

#8–250 kcmil

#8–250 kcmil

3-5/16 hub opening

1004161ACH

200

4

OH/UG

Horn

#8–350 kcmil

#8–350 kcmil

3-5/16 hub opening

1004159ACH

200

4

OH/UG

—

#8–350 kcmil

#8–350 kcmil

Hub closure plate

1008826ACH 2

200

4

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

Hub closure plate

1006352CCH 2

200

5

OH

Horn

#8–250 kcmil

#8–250 kcmil

3-5/16 hub opening

1003879ACH

200

5

OH/UG

Horn

#8–350 kcmil

#8–350 kcmil

3-5/16 hub opening

1003878ACH

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

Notes
1 Right hand incoming.
2 Austin Energy approved.

5

For dimensions, see Pages V1-T5-8 and V1-T5-9.

5
5
Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-5

5.1
5

URS101BCH

5
5
5
5
5

Metering Products
Single Meter Sockets

Residential Ringless Type Cover, continued
Connections

Ampere
Rating

Jaws

Service

Bypass

Line

Load

Opening, Hub or
Closure Plate

Catalog Number

150

4

OH/UG

—

#8–2/0 AWG

#8–2/0 AWG

Hub closure plate

1004326DCH 1

150

4

OH/UG

—

#8–250 kcmil

#8–250 kcmil

Hub opening

UTRS502BCH

150

4

OH

—

#8–250 kcmil

#8–250 kcmil

3-5/16 hub opening

UTRS502BCH

150

4

OH

—

#8–250 kcmil

#8–250 kcmil

3-5/16 hub cover plate

UTRS502CCH
1006385BCH

125

4

UG

—

N/A

N/A

N/A

125

4

OH/UG

—

#8–2/0 cu/al

#8–2/0 cu/al

3-5/16 hub opening

UTRS111BCH

125

4

OH

—

#8–2/0 cu/al

#8–2/0 cu/al

3-5/16 hub opening

UBTRS101BCH

125

4

OH

—

#8–2/0 cu/al

#8–2/0 cu/al

1-1/4-inch bolt-on hub

UTRS101LCH

125

4

OH

—

#8–2/0 cu/al

#8–2/0 cu/al

3-5/16 hub cover plate

UTRS101CE

125

4

OH

—

#8–2/0 cu/al

#8–2/0 cu/al

3-5/16 hub opening

UTRS101BE

125

4

OH

—

#8–2/0

#8–2/0

3-5/16 hub cover plate

URS101CCPLCH

125

4

OH

Horn

cu/al with
1/2-inch hex
head wire
clamping screw

cu/al with
3-5/16 hub cover plate
1/2-inch hex
head wire
clamping screw

URS101BDQCH

5

125

4

OH

—

#8–2/0

#8–2/0

3-5/16 hub opening

URS101BCPLCH

125

4

OH

—

#8–2/0

#8–2/0

3-5/16 hub opening

URS101BCH

5

125

4

OH

Horn

#8–2/0

#8–2/0

3-5/16 hub opening

UHTTRS101BCH

125

4

OH/UG

Horn

#8–250 kcmil

#8–250 kcmil

3-5/16 hub opening

UHTRS111BCH

125

4

OH

Horn

#8–2/0

#8–2/0

1.25-inch hub mounted

UHTRS101LCH

125

4

OH

Horn

#8–2/0

#8–2/0

Closure plate

UHTRS101CE

125

4

OH

Horn

#8–2/0

#8–2/0

3-5/16 hub opening

UHTRS101BE

125

5

OH/UG

—

#8–2/0

#8–2/0

3-5/16 hub cover plate

UGRS10101CKCCH

125

5

OH/UG

—

#8–2/0

#8–2/0

3-5/16 hub cover plate

UGHTRS111CCH

5

125

5

OH

—

#8–2/0

#8–2/0

3-5/16 hub opening

UGHTRS101BCH

5

125

4

OH

—

#8–2/0

#8–2/0

3-5/16 hub cover plate

UBHRS101BCH

125

4

OH/UG

—

#8–2/0

#8–2/0

3-5/16 hub cover plate

UATZRS101CFLCH

5
5
5
5

5
5
5

125

4

OH

—

#8–2/0

#8–2/0

3-5/16 hub cover plate

UATRS101CCH

125

4

OH

—

#8–2/0

#8–2/0

3-5/16 hub opening

1008947CH

5

125

4

UG

N/A

N/A

N/A

N/A

1005826ACH

5

125

4

OH

—

#8–2/0

#8–2/0

1-1/4-inch bolt-on hub

1004931BCH

125

4

OH

—

#8–2/0

#8–2/0

3-5/16 hub opening

1004162ACH

5

125

5

OH

—

#8–2/0

#8–2/0

3-5/16 hub opening

1003880ACH

125

4

OH

—

#8–2/0

#8–2/0

3-5/16 hub opening

UTZRS101BFLCH

5

125

4

OH

—

#8–2/0

#8–2/0

3-5/16 hub closure plate

UTZRS101CFLCH

125

5

OH

Horn

#8–2/0

#8–2/0

Hub opening

UTRS101CEPSEG 2

100

4

OH

—

#8–2/0

#8–2/0

3-5/16 hub opening

1009079CH

200

5

OH/UG

Horn

#8–350 kcmil

#8–350 kcmil

Hub closure plate

UTRS213CEPSEG 2

5

5
5

Notes
1 Austin Energy approved.
2 PSE&G approved.

5

For dimensions, see Pages V1-T5-8 and V1-T5-9.

5
5
5
5
5
V1-T5-6

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Metering Products
Single Meter Sockets

5.1

Residential Ring Type Cover
Connections

Ampere
Rating

Jaws

Service

Line

200

4

UG

#8–350 kcmil

200

4

OH/UG

200

4

200

5

Load

Opening, Hub or
Closure Plate

Catalog Number

#8–350 kcmil

Solid top

URTRS223ACH

#8–350 kcmil

#8–350 kcmil

3-5/16 hub cover plate

URRS213CCH

OH/UG

#8–350 kcmil

#8–350 kcmil

2 inch hub mounted

URTRS213NEUSCH

4

OH/UG

#8–350 kcmil

#8–350 kcmil

3-5/16 hub cover plate

URTRS213CEUSCH

200

4

OH/UG

#8–350 kcmil

#8–350 kcmil

3-5/16 hub cover plate

1009424CH

200

4

OH/UG

#8–350 kcmil

#8–350 kcmil

Knockouts

1009449CH

200

4

OH

#8–350 kcmil

#8–350 kcmil

3-5/16 hub opening

URSTRS203BCH

200

4

OH

#8–250 kcmil

#8–250 kcmil

3-5/16 hub cover plate

URS212BCRCH

200

4

OH/UG

#8–250 kcmil

#8–250 kcmil

3-5/16 hub cover plate

URTRS202BCH

200

4

OH

#8–250 kcmil

#8–250 kcmil

3-5/16 hub opening

URTRS213BE

200

4

OH/UG

#6–350 kcmil

#6–350 kcmil

Hub opening

URTRS202BCH

200

4

OH/UG

#6–350 kcmil

#6–350 kcmil

Closure plate

URTRS213CE

200

4

UG

#6–350 kcmil

#6–350 kcmil

3-5/16 hub opening

URTRS213BEUSCH

200

4

OH

#8–250 kcmil

#8–250 kcmil

2-inch hub mounted

URTRS202NEUSCH

200

4

OH

#8–250 kcmil

#8–250 kcmil

3-5/16 hub opening

UNRRS202BEUSCH

200

4

OH/UG

#6–350 kcmil

#6–350 kcmil

Closure plate

UNRRS213CEUSE

200

4

OH

#8–250 kcmil

#8–250 kcmil

Hub opening

UNRRS213BEUSE

200

4

UG

#6–350 kcmil

#6–350 kcmil

Solid top

UNRRS213AEUSE

200

4

OH/UG

#6–250 kcmil

#6–250 kcmil

5x5 hub opening 3-5/16 adapter plate

1009097CH

125

4

OH

#8–2/0 cu/al

#8–2/0 cu/al

3-5/16 hub opening

URS101BCRCH

125

4

OH

#8–2/0 cu/al

#8–2/0 cu/al

1-1/4-inch bolt-on hub

URRS101LCH

125

4

OH

#8–2/0 cu/al

#8–2/0 cu/al

Hub cover plate

URTRS101BE

125

4

OH

#8–2/0 cu/al

#8–2/0 cu/al

Hub cover plate

URTRS101CE

125

4

OH

#8–2/0 cu/al

#8–2/0 cu/al

3-5/16 hub cover plate

UNRRS101BEUSE

125

4

OH

#8–2/0 cu/al

#8–2/0 cu/al

Closure plate

UNRRS101CEUSE

125

4

OH/UG

#8–2/0 cu/al

#8–2/0 cu/al

3-5/16 hub cover plate

UNRRS111BEUSE

125

4

UG

#8–2/0 cu/al

#8–2/0 cu/al

Solid top

UNRRS111AEUSE

125

4

OH

#8–2/0 cu/al

#8–2/0 cu/al

3-5/16 hub opening

URSTRS101BCH

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

Note
For dimensions, see Pages V1-T5-8 and V1-T5-9.

5
5
5
5
5
5
5
5
5
5
5
Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-7

5.1
5

Metering Products
Single Meter Sockets

Dimensions
Approximate Dimensions in Inches (mm)

5
5

Residential Ringless Type Cover

Residential Ringless Type Cover, continued

Catalog Number

Height

Width

Depth

Catalog Number

Height

Width

UTRS240ACH

18.63 (473.2)

13.00 (330.2)

4.94 (125.5)

UHIRS213BCVCH

15.00 (381.0)

11.00 (279.4)

4.38 (111.3)

5

UTRS2303CCH

20.00 (508.0)

13.00 (330.2)

4.94 (125.5)

UGTRS213CE

15.13 (384.3)

11.25 (285.8)

4.50 (114.3)

UTRS223ACH

13.00 (330.2)

13.00 (330.2)

4.94 (125.5)

UGTRS213BE

15.13 (384.3)

11.25 (285.8)

4.50 (114.3)

5

UTRS220ACH

15.13 (384.3)

13.00 (330.2)

4.94 (125.5)

786685217918

15.13 (384.3)

11.25 (285.8)

4.50 (114.3)

UTRS213CFLCH

15.00 (381.0)

11.00 (279.4)

4.37 (111.0)

UGHTRS213BE

15.13 (384.3)

11.25 (285.8)

4.50 (114.3)

UTRS213CEPCH

15.00 (381.0)

11.00 (279.4)

4.37 (111.0)

UGHRS212CKCCH

14.00 (355.6)

11.00 (279.4)

4.38 (111.3)

5

UGTRS213CE

15.13 (384.3)

11.25 (285.8)

4.50 (114.3)

UFTRS202BCH

14.00 (355.6)

8.00 (203.2)

4.38 (111.3)

UTRS213CE

15.13 (384.3)

11.25 (285.8)

4.50 (114.3)

UFHTRS202BCH

14.00 (355.6)

8.00 (203.2)

4.38 (111.3)

5

UATRS213BCH

15.13 (384.3)

11.25 (285.8)

4.50 (114.3)

UBHTRS223ARHCH

13.00 (330.2)

13.00 (330.2)

4.94 (125.5)

URS213BCH

15.00 (381.0)

11.00 (279.4)

4.36 (110.7)

UBHRS223ACH

13.00 (330.2)

13.00 (330.2)

4.94 (125.5)

5

UTRS213BE

15.13 (384.3)

11.25 (285.8)

4.50 (114.3)

UBHRS202BCH

14.00 (355.6)

8.00 (203.2)

4.38 (111.3)

5

UTRS213AFLCH

15.00 (381.0)

11.00 (279.4)

4.37 (111.0)

UATRS213CFLCH

15.00 (381.0)

11.00 (279.4)

4.38 (111.3)

UTRS213ACH

15.00 (381.0)

11.00 (279.4)

4.36 (110.7)

UAHTRS233CSHCH

17.13 (435.1)

13.00 (330.2)

4.94 (125.5)

UTRS2138BCH

20.00 (508.0)

13.00 (330.2)

4.94 (125.5)

UAHTRS223AFLCH

13.00 (330.2)

13.00 (330.2)

4.94 (125.5)

UTRS212ACH

14.00 (355.6)

11.00 (279.4)

4.37 (111.0)

UAHTRS202BFLCH

14.00 (355.6)

8.00 (203.2)

4.38 (111.3)

5

UTRS212CCH

14.00 (355.6)

11.00 (279.4)

4.36 (110.7)

U92197CCCPLCH

14.13 (358.9)

13.00 (330.2)

4.94 (125.5)

5

UTRS212CFLCH

14.00 (355.6)

11.00 (279.4)

4.36 (110.7)

1009928CH

15.00 (381.0)

11.00 (279.4)

4.38 (111.3)

UTRS212BCH

14.00 (355.6)

11.00 (279.4)

4.36 (110.7)

1009874ACH

15.00 (381.0)

13.00 (330.2)

4.94 (125.5)

5

UTRS202NCH

14.00 (355.6)

8.00 (203.2)

4.36 (110.7)

1009046CH

20.75 (527.1)

9.00 (228.6)

4.94 (125.5)

14.00 (355.6)

8.00 (203.2)

4.36 (110.7)

1008941CH

17.13 (435.1)

13.00 (330.2)

4.94 (125.5)

5

UTRS232CCH

17.12 (434.8)

13.00 (330.2)

4.93 (125.2)

1008940CH

17.13 (435.1)

13.00 (330.2)

4.94 (125.5)

5

UTRS202BCH

14.00 (355.6)

8.00 (203.2)

4.36 (110.7)

1008827CH

13.00 (330.2)

13.00 (330.2)

4.94 (125.5)

URS212ACH

14.00 (355.6)

11.00 (279.4)

4.38 (111.3)

1008819CH

13.00 (330.2)

13.00 (330.2)

4.94 (125.5)

5

URS202NCH

14.00 (355.6)

8.00 (203.2)

4.38 (111.3)

1008717CH

15.00 (381.0)

13.00 (330.2)

4.94 (125.5)

URS202BDQCH

14.00 (355.6)

8.00 (203.2)

4.38 (111.3)

1008617CH

15.00 (381.0)

13.00 (330.2)

4.94 (125.5)

5

UFHTRS213CCH 2

15.00 (381.0)

11.00 (279.4)

4.38 (111.3)

1007817CH

15.00 (381.0)

11.00 (279.4)

4.38 (111.3)

UHTTRS213BCH

15.00 (381.0)

11.00 (279.4)

4.38 (111.3)

1007699CH

14.00 (355.6)

8.00 (203.2)

4.38 (111.3)

UHTTRS213CCH

15.00 (381.0)

11.00 (279.4)

4.38 (111.3)

1007665CH

14.00 (355.6)

8.00 (203.2)

4.38 (111.3)

UHTTRS202BCH

14.00 (355.6)

8.00 (203.2)

4.38 (111.3)

1007588CH

13.00 (330.2)

13.00 (330.2)

4.94 (125.5)

UHTRS233CCH

17.13 (435.1)

13.00 (330.2)

4.94 (125.5)

1007448ACH

19.00 (482.6)

11.00 (279.4)

4.38 (111.3)

5

5

5

5
5
5

UATRS202BFLCH

1

3

Depth

UHTRS223ARHCH

13.00 (330.2)

13.00 (330.2)

4.94 (125.5)

1004884ARHCH

13.00 (330.2)

13.00 (330.2)

4.93 (125.2)

UFHTRS223ACH

13.00 (330.2)

13.00 (330.2)

4.94 (125.5)

1004884ACH

13.00 (330.2)

13.00 (330.2)

4.93 (125.2)

5

UGHTRS223ACH

13.00 (330.2)

13.00 (330.2)

4.94 (125.5)

1004710ECH

14.00 (355.6)

11.00 (279.4)

4.38 (111.3)

5

UHTTRS223ACH

13.00 (330.2)

13.00 (330.2)

4.94 (125.5)

1004709DCH

N/A

N/A

N/A

UHTRS223ACH

13.00 (330.2)

13.00 (330.2)

4.94 (125.5)

1004455BCH

15.00 (381.0)

8.00 (203.2)

4.38 (111.3)

UHTRS213CE

15.00 (381.0)

11.00 (279.4)

4.38 (111.3)

1004161ACH

14.00 (355.6)

8.00 (203.2)

4.38 (111.3)

UHTRS213BE

15.00 (381.0)

11.00 (279.4)

4.38 (111.3)

1004159ACH

15.00 (381.0)

11.00 (279.4)

4.38 (111.3)

5

UHTRS213AE

15.00 (381.0)

11.00 (279.4)

4.38 (111.3)

1003879ACH

15.00 (381.0)

8.00 (203.2)

4.38 (111.3)

5

UHTRS203BCH

15.00 (381.0)

8.00 (203.2)

4.38 (111.3)

1003878ACH

15.00 (381.0)

11.00 (279.4)

4.38 (111.3)

UHTRS202BCH

14.00 (355.6)

8.00 (203.2)

4.38 (111.3)

UTRS502BCH

14.00 (355.6)

8.00 (203.2)

4.38 (111.3)

UHIRS223ACVCH

13.00 (330.2)

13.00 (330.2)

4.94 (125.5)

Notes
1 Aluminum enclosure.
2 Barrel lock.
3 Right hand incoming.

5

5
5
5

V1-T5-8

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

5.1

Metering Products
Single Meter Sockets

Approximate Dimensions in Inches (mm)

5

Residential Ringless Type Cover, continued

5

Residential Ring Type Cover

Catalog Number

Height

Width

Depth

Catalog Number

Height

Width

Depth

UTRS502BCH

14.00 (355.6)

8.00 (203.2)

4.36 (110.7)

URTRS223ACH

13.00 (330.2)

13.00 (330.2)

4.93 (125.2)

UTRS502CCH

14.00 (355.6)

8.00 (203.2)

4.36 (110.7)

URRS213CCH

15.00 (381.0)

11.00 (279.4)

4.38 (111.3)

1006385BCH

N/A

N/A

N/A

URTRS213NEUSCH

15.00 (381.0)

11.00 (279.4)

4.38 (111.3)

UTRS111BCH

14.00 (355.6)

11.00 (279.4)

4.36 (110.7)

URTRS213CEUSCH

15.00 (381.0)

11.00 (279.4)

4.38 (111.3)

UBTRS101BCH

10.88 (276.4)

8.00 (203.2)

3.50 (88.9)

1009424CH

15.00 (381.0)

11.00 (279.4)

4.38 (111.3)

UTRS101LCH

10.88 (276.4)

8.00 (203.2)

3.50 (88.9)

1009449CH

18.31 (465.1)

14.19 (360.4)

5.13 (130.3)

UTRS101CE

11.05 (280.7)

8.22 (208.8)

3.61 (91.7)

URSTRS203BCH

N/A

N/A

N/A

UTRS101BE

11.05 (280.7)

8.22 (208.8)

3.61 (91.7)

URS212BCRCH

14.00 (355.6)

8.00 (203.2)

4.38 (111.3)

URS101CCPLCH

10.88 (276.4)

8.00 (203.2)

3.50 (88.9)

URTRS202BCH

14.00 (355.6)

11.00 (279.4)

4.38 (111.3)

URS101BDQCH

10.88 (276.4)

8.00 (203.2)

3.50 (88.9)

URTRS213BE

14.00 (355.6)

8.00 (203.2)

4.50 (114.3)

URS101BCPLCH

10.88 (276.4)

8.00 (203.2)

3.50 (88.9)

URTRS202BCH

15.13 (384.3)

11.25 (285.8)

4.50 (114.3)

URS101BCH

10.88 (276.4)

8.00 (203.2)

3.50 (88.9)

URTRS213CE

15.13 (384.3)

11.25 (285.8)

4.50 (114.3)

UHTTRS101BCH

10.88 (276.4)

8.00 (203.2)

3.50 (88.9)

URTRS213BEUSCH

15.13 (384.3)

11.25 (285.8)

4.50 (114.3)

UHTRS111BCH

14.00 (355.6)

11.00 (279.4)

4.38 (111.3)

URTRS202NEUSCH

14.00 (355.6)

8.00 (203.2)

4.38 (111.3)

UHTRS101LCH

10.88 (276.4)

8.00 (203.2)

3.50 (88.9)

UNRRS202BEUSCH

14.00 (355.6)

8.00 (203.2)

4.38 (111.3)

UHTRS101CE

11.05 (280.7)

8.22 (208.8)

3.61 (91.7)

UNRRS213CEUSE

15.13 (384.3)

11.25 (285.8)

4.50 (114.3)

UHTRS101BE

11.05 (280.7)

8.22 (208.8)

3.61 (91.7)

UNRRS213BEUSE

15.13 (384.3)

11.25 (285.8)

4.50 (114.3)

UGRS10101CKCCH

12.00 (304.8)

8.00 (203.2)

3.50 (88.9)

UNRRS213AEUSE

15.13 (384.3)

11.25 (285.8)

4.50 (114.3)

UGHTRS111CCH

14.00 (355.6)

11.00 (279.4)

4.36 (110.7)

1009097CH

19.00 (482.6)

13.00 (330.2)

5.25 (133.4)

UGHTRS101BCH

10.88 (276.4)

8.00 (203.2)

3.50 (88.9)

URS101BCRCH

10.88 (276.4)

8.00 (203.2)

3.50 (88.9)

UBHRS101BCH

10.88 (276.4)

8.00 (203.2)

3.50 (88.9)

URRS101LCH

10.88 (276.4)

8.00 (203.2)

3.50 (88.9)

UATZRS101CFLCH

10.88 (276.4)

8.00 (203.2)

3.50 (88.9)

URTRS101BE

11.00 (279.4)

8.25 (209.6)

3.63 (92.2)

UATRS101CCH

10.87 (276.1)

8.00 (203.2)

3.50 (88.9)

URTRS101CE

11.00 (279.4)

8.25 (209.6)

3.63 (92.2)

1008947CH

10.89 (276.6)

8.00 (203.2)

3.50 (88.9)

UNRRS101BEUSE

10.88 (276.4)

8.00 (203.2)

3.50 (88.9)

1005826ACH

N/A

N/A

N/A

UNRRS101CEUSE

10.88 (276.4)

8.00 (203.2)

3.50 (88.9)

1004931BCH

10.88 (276.4)

8.00 (203.2)

3.50 (88.9)

UNRRS111BEUSE

14.00 (355.6)

11.00 (279.4)

4.38 (111.3)

1004162ACH

10.89 (276.6)

8.00 (203.2)

3.50 (88.9)

URSTRS101BCH

10.88 (276.4)

8.00 (203.2)

3.50 (88.9)

1003880ACH

10.89 (276.6)

8.00 (203.2)

3.50 (88.9)

UTZRS101BFLCH

N/A

N/A

N/A

UTZRS101CFLCH

N/A

N/A

N/A

1009079CH

23.75 (603.3)

8.00 (203.2)

3.48 (88.4)

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-9

5.2
5

Metering Products
Commercial Lever Bypass Sockets

Contents

Commercial Lever Bypass Sockets

Description

5

Catalog Number Selection . . . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5
5
5
5
5
5
5
5
5
5

Product Description
●

5

●

5

●

5
5
5

●
●
●

Heavy-duty, lever bypass,
jaw clamping ringless
meter socket design
200A and 320A
styles available
Single-phase or
three-phase
4, 5 or 7 terminal available
600 Vac maximum rating
Multiple service
design offerings

Standards and
Certifications
●

UL 414 listed and
recognized

5
5
5
5
5
5
5
5
5
5
5
5
5
V1-T5-10

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Page
V1-T5-11
V1-T5-12
V1-T5-16

Metering Products
Commercial Lever Bypass Sockets

5.2

Catalog Number Selection

5
5

Single Meter Sockets H Group

5

UT H 4 2 0 3 B CH
Note: The “U” prefix is always used first followed by
other prefixes required in alphabetical order.
Standard Prefixes
A = Aluminum enclosure
B = Barrel lock provision, for an exposed INNER-TITE or Brooks barrel lock;
unit includes an internal lock receiver bracket
F = Barrel Lock with guard provision, for a lock guard INNER-TITE or
Brooks barrel lock; unit includes an internal lock receiver bracket
G = Grounded fifth terminal (9 o’clock position)
H = Horn bypass
I = Inhibitor installed in wire connectors
M = Temporary meter cover (waxed cardboard)
N = No sealing ring (applies only to ring style sockets)
R = Ring style socket
S = Aluminum screw type sealing ring (applies only to ring style sockets)
T = Grounding connector (#14–#2 Cu) for triplex ground
TT = Two grounding connectors (#14–#2 Cu) for quadplex ground
U = UL label
Z = 5/16-inch hex head connector screw in place of slotted (100A only)

RS
2R-6R
2H-6H
H

=
=
=
=

5

Standard Suffixes

Product Group
Residential service, single position
Residential service, multiple position
Commercial or residential service, multiple position
Commercial or residential service, single position
Jaw Quantity
4 = 4 terminals
5 = 5 terminals
7 = 7 terminals

5

A = Solid top
B = Small hub opening
C = Small hub closing plate mounted
L = 1.25-inch (31.8 mm) hub mounted
M = 1.50-inch (38.1 mm) hub mounted
N = 2.00-inch (50.8 mm) hub mounted
P = 2.50-inch (63.5 mm) hub mounted
T = Large hub opening hub
U = Large hub cover plate hub mounted
V = 2.50-inch (63.5 mm) large hub mounted
Q = 3.00-inch (76.2 mm) large hub mounted
R = 3.50-inch (88.9 mm) large hub mounted
S = 4.00-inch (101.6 mm) large hub mounted
Z = Large to small hub adapter mounted

5
5
5
5
5

Maximum Conductor (Line & Load)
0 = 0.38-inch stud connectors
3 = #350 kcmil connectors
5 = #500 kcmil connectors
6 = #600 kcmil connectors
7 = #750 kcmil connectors
8 = Dual #250 kcmil connectors
9 = Dual #350 kcmil connectors

5
5
5
5

Service Design
0 = Overhead
1 = Combination overhead/underground
2 = Underground, side wired
3 = Combination overhead/underground, side wired

5
5

Ampere Rating
2 = 200A
3 = 320A

5
5
5
5
5
5
5
5
5
5
5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-11

5.2

Metering Products
Commercial Lever Bypass Sockets

5

Product Selection

5

Commercial Lever Bypass

5

Ampere
Rating

Jaws

Service

Bypass

Line

5

320

7

OH/UG

Lever

320

7

OH

Lever

5

320

7

OH/UG

320

7

OH/UG

5

Connections
Load

Opening, Hub or
Closure Plate

Catalog Number

#4-600 kcmil

#4–600 kcmil

5x5 hub opening

UTTH7336TCH

#600 kcmil

Dual #6–350

5x5 hub opening

UTH73069THLCH

Lever

#14–1/0 cu/al

#6–350 kcmil

5x5 hub cover plate

UTH73369UHLCH

Lever

#14–1/0 cu/al

#6–350 kcmil

5x5 hub opening

UTH73369THLCH

320

7

OH/UG

Lever

3/8-inch studs

3/8-inch studs

5x5 hub cover plate

UFTH7330UCH

5

320

7

OH/UG

Lever

#600 kcmil

#600 kcmil

5x5 hub opening

UTH7336TCH

320

7

OH/UG

Lever

3/8-inch studs

3/8-inch studs

5x5 hub cover plate

UTH7330UCH

5

320

7

OH/UG

Lever

3/8-inch studs

3/8-inch studs

5x5 hub cover plate

UTH7330UFLCH

320

7

OH/UG

Lever

3/8-inch studs

3/8-inch studs

5x5 hub cover plate

UATH7330UFLCH 1

320

7

OH/UG

Lever

3/8-inch studs

3/8-inch studs

5x5 hub opening

UH7330TCPLCH

5
5

320

7

OH/UG

Lever

3/8-inch studs

3/8-inch studs

5x5 hub opening

UTH7330TCH

320

7

OH/UG

Lever

3/8-inch studs

3/8-inch studs

5x5 hub-inch opening

UTTH7330TCH

5

320

7

OH/UG

Lever

3/8-inch studs

3/8-inch studs

5x5 hub cover plate

UH7300UCPLCH

320

7

OH/UG

Lever

3/8-inch studs

3/8-inch studs

5x5 hub cover plate

UTH7300UCH

320

7

OH/UG

Lever

3/8-inch studs

3/8-inch studs

5x5 hub opening

UTH7300TCH

320

7

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

Hub closure plate

1006353CCH 2

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

320

5

OH/UG

Lever

3/8-inch studs

3/8-inch studs

5x5 hub cover plate

UTH5330UFLCH

320

5

OH/UG

Lever

3/8-inch studs

3/8-inch studs

5x5 hub cover plate

UTH5330UCH

320

5

OH

Lever

3/8-inch studs

3/8-inch studs

5x5 hub opening

UTH5300TCH

320

5

OH/UG

Lever

3/8-inch studs

3/8-inch studs

5x5 hub cover plate

UATH5330UFLCH

320

4

OH/UG

lever

#4–600 kcmil

#4–600 kcmil

Hub closure plate

1010468CH 2

320

4

UG

Lever

3/8-inch studs

3/8-inch studs

Solid top

UTH4320ACH

320

4

UG

Lever

3/8-inch studs

Dual #6–350

Solid top

UTH43209ACH

320

4

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

5x5 hub cover plate

UTH4339UCH

320

4

OH/UG

Lever

#6–250 kcmil

#6–250 kcmil

5x5 hub cover plate

UTH4338UCH

320

4

OH/UG

Lever

#4–600 kcmil

#4–600 kcmil

5x5 hub cover plate

UTH4336UCH

320

4

OH/UG

Lever

#4–600 kcmil

#4–600 kcmil

5x5 hub opening

UTH4336TCH

320

4

OH/UG

Lever

#4–600 kcmil

#6–350 kcmil

5x5 hub cover plate

UTH43369UCH
UTH43369TCH

320

4

OH/UG

Lever

#4–600 kcmil

#6–350 kcmil

5x5 hub opening

320

4

OH/UG

Lever

3/8-inch studs

3/8-inch studs

3-5/16 hub cover plate

UTTH4330UCH

320

4

OH/UG

Lever

3/8-inch studs

3/8-inch studs

3-5/16 hub cover plate

UTH4330UCH

320

4

OH/UG

Lever

3/8-inch studs

3/8-inch studs

5x5 hub opening

UBTH4330TCH

320

4

OH/UG

Lever

3/8-inch studs

3/8-inch studs

5x5 hub opening

UTH4330TCH

320

4

OH/UG

Lever

3/8-inch studs

3/8-inch studs

5x5 cover plate

UTH4300UCH

320

4

OH/UG

Lever

3/8-inch studs

3/8-inch studs

5x5 hub opening

UTH4300TCH

320

5

OH/UG

Lever

3/8-inch studs

3/8-inch studs

5x5 hub cover plate

UH5300UKCCH

320

4

OH/UG

Lever

#6–250 kcmil

#4–600 kcmil

5x5 hub cover plate

UH43168UCPLCH

320

4

OH/UG

Lever

#4–600 kcmil

#6–250 kcmil

5x5 hub cover plate

UH43068TCPLCH

320

5

OH/UG

Lever

3/8-inch studs

3/8-inch studs

5x5 hub cover plate

UGTH4330UCH

320

5

OH/UG

Lever

3/8-inch studs

3/8-inch studs

5x5 hub opening

UGTH4330TCH

320

7

OH/UG

Lever

3/8-inch studs

3/8-inch studs

5x5 hub opening

UFTH7330TCH

320

4

OH/UG

Lever

3/8-inch studs

3/8-inch studs

5x5 hub opening

UFTH4330TCH

5

Notes
1 Aluminum enclosure.
2 Austin Energy approved.

5

For dimensions, see Pages V1-T5-16 and V1-T5-17.

V1-T5-12

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Metering Products
Commercial Lever Bypass Sockets

5.2

Commercial Lever Bypass, continued
Connections

Ampere
Rating

Jaws

Service

Bypass

Line

320

7

OH/UG

Lever

#4–600 kcmil

320

5

OH/UG

Lever

320

4

OH/UG

Lever

320

4

OH/UG

320

4

320

4

320

4

OH/UG

Lever

Dual #6–350

320

4

OH/UG

Lever

Dual #6–350

320

4

OH/UG

Lever

3/8-inch studs

320

4

OH/UG

Lever

320

7

OH/UG

Lever

320

4

UG

320

4

320

4

320

5

Load

Opening, Hub or
Closure Plate

Catalog Number

#4–600 kcmil

5x5 hub opening

UATH7336TCH

3/8-inch studs

3/8-inch studs

5x5 hub cover plate

UATH5330UFLCH

#4–600 kcmil

#4–600 kcmil

5x5 hub opening

UATH4336TCH

Lever

3/8-inch studs

3/8-inch studs

5x5 hub opening

UATH4330TCH

OH/UG

Lever

3/8-inch studs

3/8-inch studs

5x5 hub cover plate

1009788CH

OH/UG

Lever

3/8-inch studs

3/8-inch studs

5x5 hub cover plate

1009788ACH 1

Dual #6–350

(2) 5x5 hub cover plates

1009760ACH

Dual #6–350

5x5 hub cover plate

1009722CH

3/8-inch studs

5x5 hub cover plate

782116975945

3/8-inch studs

3/8-inch studs

5x5 hub cover plate

1009260CH

#4–600 kcmil/Dual 1/0–250
kcmil cu/al

#4–600 kcmil/Dual 1/0–250
kcmil cu/al

5x5 hub opening

1009181CH

Lever

#6–350 kcmil

#6–350 kcmil

Solid top

1009018CH

OH/UG

Lever

3/8-inch studs

3/8-inch studs

5x5 hub opening

1008950CH

OH/UG

Lever

3/8-inch studs

3/8-inch studs

5x5 hub opening

1008948CH

4

UG

Lever

3/8-inch studs

3/8-inch studs

Solid top

1008848CH

320

4

OH/UG

Lever

3/8-inch studs

3/8-inch studs

5x5 hub opening

1008837CH

320

4

OH/UG

Lever

3/8-inch studs

3/8-inch studs

5x5 hub opening

1008836CH

320

7

OH/UG

Lever

3/8-inch studs

3/8-inch studs

5x5 hub opening

1008798CH

320

4

OH/UG

Lever

3/8-inch studs

3/8-inch studs

5x5 hub opening

1008793CH

320

5

OH/UG

Lever

3/8-inch studs

3/8-inch studs

5x5 hub opening

1008792CH

320

7

OH/UG

Lever

#4–600 kcmil/Dual 1/0–250
kcmil cu/al

#4–600 kcmil/Dual 1/0–250
kcmil cu/al

5x5 hub opening

1008543CH

5

320

4

OH/UG

Lever

#4–600 kcmil cu/al

#4–600 kcmil cu/al

5x5 hub opening

1008541CH

320

4

UG

Lever

N/A

N/A

Solid top

1008540CH

5

320

4

OH/UG

Lever

#4–600 kcmil cu/al

#4–600 kcmil cu/al

Solid top

1008435CH

320

4

OH/UG

Lever

3/8-inch studs

3/8-inch studs

5x5 hub opening

1008191CH

320

4

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

5x5 hub opening

1008068CH

320

4

OH/UG

Lever

N/A

N/A

N/A

1007818CH

320

4

OH/UG

Lever

3/8-inch studs

3/8-inch studs

5x5 hub opening

1007801CH

320

4

OH/UG

Lever

3/8-inch studs

3/8-inch studs

5x5 hub opening

1007672CH

320

4

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

5x5 hub opening

1006344ACH

320

4

OH/UG

Lever

TBD

TBD

5x5 hub opening

1004984ACH

320

4

OH/UG

N/A

#4–600 kcmil

#4–600 kcmil

3-inch bolt-on hub

1004771BCH

200

7

OH/UG

Lever

3/8-inch studs

3/8-inch studs

N/A

UBTH7230ACH

200

7

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

5x5 hub cover plate

UTH7233UCH

5
5
5
5
5
5
5
5
5
5
5
5
5

5
5
5
5
5

Notes
1 Bolted in shield.

5
5
5

For dimensions, see Pages V1-T5-16 and V1-T5-17.

5
5
5
5
5
5
Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-13

5.2

Metering Products
Commercial Lever Bypass Sockets

5

Commercial Lever Bypass, continued

5

Ampere
Rating

Jaws

Service

Bypass

Line

Load

Opening, Hub or
Closure Plate

Catalog Number

200

7

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

5x5 hub cover plate

UTE7213UFLCH

200

7

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

3-5/16 hub cover plate

UETH72137UCH

200

7

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

3-5/16 hub cover plate

UTE7213UCH

200

7

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

5x5 hub opening

UTE7213THLCH

5

200

7

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

5x5 hub opening

UBHRS212BCH

5

200

7

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

5x5 hub opening

UBEH7213TCH

200

7

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

5x5 hub opening

UFTE7213TCH 1

5

200

7

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

Large to small hub adapter

UTE7213ZCH

200

7

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

5x5 hub opening

UTE7213TCH

5

200

7

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

3-5/16 hub cover plate

UTE7213CFLCH

5

200

7

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

3-5/16 hub cover plate

UTE7213CCH

200

7

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

3-5/16 hub opening

UBTE7213BCH

200

7

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

3-5/16 hub opening

UTE7213BCH

200

7

OH/UG

Lever

3/8-inch studs

3/8-inch studs

5x5 hub cover plate

UTE7210UCH
UTE7203TCH

5
5

5
5

Connections

200

7

OH

Lever

#6–350 kcmil

#6–350 kcmil

5x5 hub opening

200

7

OH

Lever

#6–350 kcmil

#6–350 kcmil

3-5/16 hub opening

UTE7203BCH

200

5

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

5x5 hub cover plate

UETH5213UCH

5

200

5

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

5x5 hub opening

UTE5213TCH

200

5

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

5x5 hub opening

UTTE5213TCH

5

200

5

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

3-5/16 hub cover plate

UTE5213CCH

200

5

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

3-5/16 hub opening

UTE5213BNDCH

5

200

5

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

Large to small hub adapter

UTE5213ZCH

5

200

5

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

5x5 hub cover plate

UTE5213UFLCH

200

5

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

3-5/16 hub cover plate

UTE5213CFLCH

200

5

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

3-5/16 hub opening

UTE5213BCH

200

5

OH/UG

Lever

3/8-inch studs

3/8-inch studs

3-5/16 hub cover plate

UTE5210CCH

5

200

5

OH

Lever

#6–350 kcmil

#6–350 kcmil

3-5/16 hub opening

UTE5203BCH

5

200

4

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

5x5 hub opening with adapter plate

UTE4213ZCH

200

5

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

5x5 hub cover plate

UGTE4213CCH

200

4

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

5x5 hub opening

UTE4213TCH

200

4

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

5x5 hub cover plate

UTTE4213UCH 2

5

5

5
5
5
5
5
5
5
5

200

4

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

5x5 hub cover plate

UTE4213CCH

200

4

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

3-5/16 hub opening

UTE4213BCH

200

4

OH

Lever

#6–350 kcmil

#6–350 kcmil

3-5/16 hub opening

UTE4203BCH

200

7

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

5x5 hub cover plate

UIH7213UCVCH

200

7

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

3-5/16 hub cover plate

UE7213CCCCH

200

7

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

3-5/16 hub cover plate

UE7213CCPLCH

200

7

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

3-5/16 hub opening

UE7213BCPLCH

Notes
1 Barrel lock.
2 TT = quadplex ground.
For dimensions, see Pages V1-T5-16 and V1-T5-17.

5
5
5
V1-T5-14

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Metering Products
Commercial Lever Bypass Sockets

5.2

Commercial Lever Bypass, continued
Connections

Ampere
Rating

Jaws

Service

Bypass

Line

200

5

OH/UG

Lever

#6–350 kcmil

200

4

OH/UG

Lever

200

7

OH/UG

Lever

200

7

OH/UG

5

Load

Opening, Hub or
Closure Plate

Catalog Number

#6–350 kcmil

3-5/16 hub opening

UGTE4213BCH

#6–350 kcmil

#6–350 kcmil

3-5/16 hub cover plate

UGE4213CCCCH

#6–350 kcmil

#6–350 kcmil

3-5/16 hub opening

UFTE7213BCH

Lever

#6–350 kcmil

#6–350 kcmil

5x5 hub opening

UATE7213TCH

200

5

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

3-5/16 hub cover plate

UATE5213CCH

200

4

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

5x5 hub cover plate

UATE4213UFLCH

200

5

OH

Lever

#6–350 kcmil

#6–350 kcmil

3-5/16 hub opening

UBGTE4203BCH

200

7

UG

Lever

4/0 compression line

#6–350 kcmil cu/al load

Solid top

1009845ECH

200

5

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

3-5/16 hub cover plate

1008801ECH

200

5

OH/UG

Lever

3/8-inch studs

3/8-inch studs

3-5/16 hub cover plate

1008832ECH

200

4

UG

Lever

#6–350 kcmil

#6–350 kcmil

Solid top

1007944ECH

200

7

OH/UG

Lever

#6–350 kcmil cu/al

#6–350 kcmil cu/al

5x5 hub opening

1007670ECH

200

7

OH/UG

Lever

#6–350 kcmil

#6–350 kcmil

5x5 hub opening

UTTE7213TCH

5
5
5
5
5
5
5
5

Note
For dimensions, see Pages V1-T5-16 and V1-T5-17.

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-15

5.2
5

Metering Products
Commercial Lever Bypass Sockets

Dimensions
Approximate Dimensions in Inches (mm)

5
5

Commercial Lever Bypass

Commercial Lever Bypass, continued

Catalog Number

Height

Width

Depth

Catalog Number

Height

Width

Depth

UTTH7336TCH

39.89 (1013.2)

20.00 (508.0)

6.50 (165.1)

UATH7336TCH

39.88 (1013.0)

20.00 (508.0)

6.50 (165.1)

5

UTH73069THLCH

N/A

N/A

N/A

UATH5330UFLCH

39.88 (1013.0)

20.00 (508.0)

6.50 (165.1)

UTH73369UHLCH

39.89 (1013.2)

20.00 (508.0)

6.50 (165.1)

UATH4336TCH

36.63 (930.4)

15.00 (381.0)

5.69 (144.5)

5

UTH73369THLCH

39.89 (1013.2)

20.00 (508.0)

6.50 (165.1)

UATH4330TCH

36.63 (930.4)

15.00 (381.0)

5.69 (144.5)

UFTH7330UCH

39.89 (1013.2)

20.00 (508.0)

6.50 (165.1)

1009788CH

34.50 (876.3)

13.00 (330.2)

4.94 (125.5)

UTH7336TCH

39.89 (1013.2)

20.00 (508.0)

6.50 (165.1)

1009788ACH 2

34.50 (876.3)

13.00 (330.2)

4.94 (125.5)

UTH7330UCH

39.89 (1013.2)

20.00 (508.0)

6.50 (165.1)

1009760ACH

36.63 (930.4)

15.00 (381.0)

5.68 (144.3)

UTH7330UFLCH

39.89 (1013.2)

20.00 (508.0)

6.50 (165.1)

1009722CH

36.63 (930.4)

15.00 (381.0)

5.68 (144.3)

5

5
5
5

1

39.89 (1013.2)

20.00 (508.0)

6.50 (165.1)

782116975945

36.63 (930.4)

15.00 (381.0)

5.69 (144.5)

UH7330TCPLCH

39.89 (1013.2)

20.00 (508.0)

6.50 (165.1)

1009260CH

36.63 (930.4)

15.00 (381.0)

5.69 (144.5)

5

UTH7330TCH

39.89 (1013.2)

20.00 (508.0)

6.50 (165.1)

1009181CH

34.50 (876.3)

15.00 (381.0)

5.69 (144.5)

5

UTTH7330TCH

39.89 (1013.2)

20.00 (508.0)

6.50 (165.1)

1009018CH

63.00 (1600.2)

12.97 (329.4)

4.94 (125.5)

UH7300UCPLCH

39.89 (1013.2)

20.00 (508.0)

6.50 (165.1)

1008950CH

39.88 (1013.0)

20.00 (508.0)

6.50 (165.1)

UTH7300UCH

39.89 (1013.2)

20.00 (508.0)

6.50 (165.1)

1008948CH

36.63 (930.4)

15.00 (381.0)

5.69 (144.5)

UTH7300TCH

34.50 (876.3)

15.00 (381.0)

5.63 (143.0)

1008848CH

58.00 (1473.2)

12.97 (329.4)

4.94 (125.5)

5

UTH5330UFLCH

39.88 (1013.0)

20.00 (508.0)

6.50 (165.1)

1008837CH

36.63 (930.4)

15.00 (381.0)

6.50 (165.1)

5

UTH5330UCH

39.88 (1013.0)

20.00 (508.0)

6.50 (165.1)

1008836CH

36.63 (930.4)

15.00 (381.0)

6.50 (165.1)

UTH5300TCH

39.88 (1013.0)

20.00 (508.0)

6.50 (165.1)

1008798CH

34.50 (876.3)

15.00 (381.0)

5.69 (144.5)

5

UATH5330UFLCH

39.88 (1013.0)

20.00 (508.0)

6.50 (165.1)

1008793CH

34.50 (876.3)

13.00 (330.2)

4.94 (125.5)

UTH4320ACH

26.00 (660.4)

15.00 (381.0)

5.68 (144.3)

1008792CH

34.50 (876.3)

13.00 (330.2)

4.94 (125.5)

5

UTH43209ACH

N/A

N/A

N/A

1008543CH

39.89 (1013.2)

20.00 (508.0)

6.60 (167.6)

5

UTH4339UCH

36.63 (930.4)

15.00 (381.0)

5.69 (144.5)

1008541CH

36.63 (930.4)

15.00 (381.0)

5.69 (144.5)

UTH4338UCH

29.00 (736.6)

15.00 (381.0)

5.69 (144.5)

1008540CH

N/A

N/A

N/A

5

UTH4336UCH

36.63 (930.4)

15.00 (381.0)

5.69 (144.5)

1008435CH

26.00 (660.4)

15.00 (381.0)

5.69 (144.5)

UTH4336TCH

36.63 (930.4)

15.00 (381.0)

5.69 (144.5)

1008191CH

36.63 (930.4)

15.00 (381.0)

5.69 (144.5)

5

UTH43369UCH

36.63 (930.4)

15.00 (381.0)

5.69 (144.5)

1008068CH

34.50 (876.3)

16.44 (417.6)

6.50 (165.1)

UTH43369TCH

36.63 (930.4)

15.00 (381.0)

5.69 (144.5)

1007818CH

N/A

N/A

N/A

UTTH4330UCH

36.63 (930.4)

15.00 (381.0)

5.69 (144.5)

1007801CH

28.50 (723.9)

18.00 (457.2)

5.69 (144.5)

5

UTH4330UCH

36.63 (930.4)

15.00 (381.0)

5.69 (144.5)

1007672CH

36.63 (930.4)

15.00 (381.0)

5.69 (144.5)

UBTH4330TCH

36.63 (930.4)

15.00 (381.0)

5.69 (144.5)

1006344ACH

28.50 (723.9)

18.00 (457.2)

5.69 (144.5)

5

UTH4330TCH

36.63 (930.4)

15.00 (381.0)

5.69 (144.5)

1004984ACH

36.63 (930.4)

15.00 (381.0)

5.69 (144.5)

UTH4300UCH

34.50 (876.3)

13.00 (330.2)

4.94 (125.5)

1004771BCH

36.62 (930.1)

15.00 (381.0)

5.68 (144.3)

5

UTH4300TCH

34.50 (876.3)

13.00 (330.2)

4.94 (125.5)

UBTH7230ACH

N/A

N/A

N/A

5

UH5300UKCCH

34.50 (876.3)

13.00 (330.2)

4.94 (125.5)

UTH7233UCH

27.00 (685.8)

16.00 (406.4)

5.63 (143.0)

UH43168UCPLCH

34.50 (876.3)

15.00 (381.0)

5.69 (144.5)

UH43068TCPLCH

34.50 (876.3)

13.00 (330.2)

4.94 (125.5)

UGTH4330UCH

36.63 (930.4)

15.00 (381.0)

5.69 (144.5)

Notes
1 Aluminum enclosure.
2 Bolted in shield.

5

UGTH4330TCH

36.63 (930.4)

15.00 (381.0)

5.69 (144.5)

5

UFTH7330TCH

39.88 (1013.0)

20.00 (508.0)

6.50 (165.1)

UFTH4330TCH

36.63 (930.4)

15.00 (381.0)

5.69 (144.5)

V1-T5-16

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

5

5

5

UATH7330UFLCH

5
5
5

5.2

Metering Products
Commercial Lever Bypass Sockets

Approximate Dimensions in Inches (mm)

5

Commercial Lever Bypass, continued

5

Commercial Lever Bypass, continued

Catalog Number

Height

Width

Depth

Catalog Number

Height

Width

Depth

UTE7213UFLCH

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

UGTE4213BCH

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

UETH72137UCH

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

UGE4213CCCCH

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

UTE7213UCH

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

UFTE7213BCH

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

UTE7213THLCH

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

UATE7213TCH

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

UBHRS212BCH

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

UATE5213CCH

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

UBEH7213TCH

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

UATE4213UFLCH

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

UFTE7213TCH 1

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

UBGTE4203BCH

19.00 (482.6)

10.50 (266.7)

4.94 (125.5)

UTE7213ZCH

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

1009845ECH

64.00 (1625.6)

11.00 (279.4)

6.00 (152.4)

UTE7213TCH

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

1008801ECH

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

UTE7213CFLCH

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

1008832ECH

24.69 (627.1)

13.00 (330.2)

4.94 (125.5)

UTE7213CCH

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

1007944ECH

22.00 (558.8)

16.00 (406.4)

5.69 (144.5)

UBTE7213BCH

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

1007670ECH

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

UTE7213BCH

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

UTTE7213TCH

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

UTE7210UCH

24.69 (627.1)

13.00 (330.2)

4.94 (125.5)

UTE7203TCH

19.00 (482.6)

10.50 (266.7)

4.94 (125.5)

UTE7203BCH

19.00 (482.6)

10.50 (266.7)

4.94 (125.5)

Notes
1 Barrel lock.
2 TT = quadplex ground.

UETH5213UCH

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

UTE5213TCH

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

UTTE5213TCH

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

UTE5213CCH

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

UTE5213BNDCH

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

UTE5213ZCH

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

UTE5213UFLCH

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

UTE5213CFLCH

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

UTE5213BCH

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

UTE5210CCH

20.13 (511.3)

13.00 (330.2)

4.94 (125.5)

UTE5203BCH

19.00 (482.6)

10.50 (266.7)

4.94 (125.5)

UTE4213ZCH

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

UGTE4213CCH

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

UTE4213TCH

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

UTTE4213UCH 2

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

UTE4213CCH

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

UTE4213BCH

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

UTE4203BCH

19.00 (482.6)

10.50 (266.7)

4.94 (125.5)

UIH7213UCVCH

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

UE7213CCCCH

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

UE7213CCPLCH

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

UE7213BCPLCH

19.00 (482.6)

13.00 (330.2)

4.94 (125.5)

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-17

5.3
5

Metering Products
Multiple Position Horizontal Ganged Sockets

Multiple Position Horizontal Ganged Sockets

Contents
Description

5

Catalog Number Selection . . . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

5
5
5
5
5
5
5
5
5
5
5

Product Description
●

●

5

●

5

●

5

●

5

●

5

Available in 100A and
200A designs
Available in 2-position
through 6-position designs
Multiple service
design offerings
Multiple line/load
lug configurations
Residential or lever
bypass socket designs
Multiple hub opening
and closure plate
sizes available

5
5
5
5
5
5
5
5
5
5
5
5
V1-T5-18

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Page
V1-T5-19
V1-T5-20
V1-T5-23

Metering Products
Multiple Position Horizontal Ganged Sockets

5.3

Catalog Number Selection

5
5

Single Meter Sockets 2R-6R and 2H-6H Group

5

UT 2R 1 1 2 1 B CH
Note: The “U” prefix is always used first followed by
other prefixes required in alphabetical order.
Standard Prefixes
A = Aluminum enclosure
B = Barrel lock provision, for an exposed INNER-TITE or Brooks barrel lock;
unit includes an internal lock receiver bracket
F = Barrel lock with guard provision, for a lock guard INNER-TITE or
Brooks barrel lock; unit includes an internal lock receiver bracket
G = Grounded fifth terminal (9 o’clock position)
H = Horn bypass
I = Inhibitor installed in wire connectors
M = Temporary meter cover (waxed cardboard)
N = No sealing ring (applies only to ring style sockets)
R = Ring style socket
S = Aluminum screw type sealing ring (applies only to ring style sockets)
T = Grounding connector (#14–#2 Cu) for triplex ground
TT = Two grounding connectors (#14–#2 Cu) for quadplex ground
U = UL label
Z = 5/16-inch hex head connector screw in place of slotted (100A only)

RS
=
2R-6R =
2H-6H =
H
=

5

Standard Suffixes

Product Group
Residential service, single position
Residential service, multiple position
Commercial or residential service, multiple position
Commercial or residential service, single position
Ampere Rating
1 = 100A
2 = 200A

5

A = Solid top
B = Small hub opening
C = Small hub closing plate mounted
L = 1.25-inch (31.8 mm) hub mounted
M = 1.50-inch (38.1 mm) hub mounted
N = 2.00-inch (50.8 mm) hub mounted
P = 2.50-inch (63.5 mm) hub mounted
T = Large hub opening hub
U = Large hub cover plate hub mounted
V = 2.50-inch (63.5 mm) large hub mounted
Q = 3.00-inch (76.2 mm) large hub mounted
R = 3.50-inch (88.9 mm) large hub mounted
S = 4.00-inch (101.6 mm) large hub mounted
Z = Large to small hub adapter mounted

5
5
5
5
5

Maximum Load Conductor
0 = 0.38-inch stud connectors
1 = #2/0 connectors
2 = #250 kcmil connectors
3 = #350 kcmil connectors
5 = #500 kcmil connectors
6 = #600 kcmil connectors
7 = #750 kcmil connectors
8 = Dual #500 kcmil connectors

5
5
5
5

Maximum Line Conductor
0 = 0.38-inch stud connectors
1 = #2/0 connectors
2 = #250 kcmil connectors
3 = #350 kcmil connectors
5 = #500 kcmil connectors
6 = #600 kcmil connectors
7 = #750 kcmil connectors
8 = Dual #500 kcmil connectors

5
5
5
5

Service Design

5

0 = Overhead
1 = Combination overhead/underground
2 = Underground, side wired
3 = Combination overhead/underground, side wired
4 = End feed

5
5
5
5
5
5
5
5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-19

5.3
5
5
5

Metering Products
Multiple Position Horizontal Ganged Sockets

Product Selection

UT2R2332BCH

Horizontal Design—Multi Position Ringless
Connections

Ampere
Rating

Jaws

Position

Service

Bypass

Line

Load

Opening, Hub or
Closure Plate

Catalog Number

200

4

2

OH/UG

Horn

#6–350 kcmil

#8–250 kcmil

5x5 hub opening

1004401BCH

5

200

4

3

OH/UG

Horn

#6–350 kcmil

#8–250 kcmil

5x5 hub opening

1004404BCH

200

5

2

OH/UG

Horn

#6–350 kcmil

#8–250 kcmil

5x5 hub opening

1004418ACH

5

200

4

2

OH/UG

—

3/8-inch stud

#8–250 kcmil

5x5 hub cover plate

1006737BCH

5

200

4

2

OH/UG

Horn

3/8-inch stud

#8–250 kcmil

5x5 hub opening

1007700CH

200

4

3

OH/UG

Horn

3/8-inch stud

#8–250 kcmil

Hub opening

1007701CH

5

200

4

2

OH/UG

Horn

#6–350 kcmil

#8–250 kcmil

5x5 hub cover plate

1008842CH

200

4

3

OH/UG

Horn

1/0–500 kcmil cu/al

#8–250 kcmil

5x5 hub cover plate

1008843CH

5

200

4

4

OH/UG

Horn

1/0–500 kcmil cu/al

#8–250 kcmil

5x5 hub cover plate

1008844CH

200

4

2

OH/UG

Horn

#6–350 kcmil

#8–250 kcmil

5x5 hub cover plate

1008958CH

200

4

3

OH/UG

Horn

1/0–500 kcmil cu/al

#8–250 kcmil

5x5 hub cover plate

1008959CH

5

200

4

4

OH/UG

Horn

1/0–500 kcmil cu/al

#8–250 kcmil

5x5 hub cover plate

1008960CH

200

4

5

OH/UG

Horn

(2) 1/0–500 kcmil cu/al #8–250 kcmil

(2) 5x5 hub cover plate

1009579ACH

5

200

4

4

OH/UG

Horn

1/0–500 kcmil cu/al

5x5 hub opening

U4R2352TDQCH

200

4

5

OH/UG

Horn

(2) 1/0–500 kcmil cu/al #8–250 kcmil

(2) 5x5 hub opening

U5R2392TTDQCH

5

200

4

6

OH/UG

Horn

(2) 1/0–500 kcmil cu/al #8–250 kcmil

5x5 hub opening (2) places

U6R2392TTDQCH

5

200

4

4

OH/UG

Horn

1/0–500 kcmil cu/al

#8–250 kcmil

5x5 hub opening

UBH4R2352TCH

200

4

2

OH/UG

Horn

#6–350 kcmil

#8–250 kcmil

5x5 hub opening

UBH2R2332TCH

200

4

3

OH/UG

Horn

#6–350 kcmil

#8–250 kcmil

5x5 hub opening

UBH3R2332TCH

200

4

4

OH/UG

Horn

3/8-inch stud

#8–250 kcmil

5x5 hub cover plate

UEHT4R2302UCH

5

200

4

3

OH/UG

Horn

3/8-inch stud

#8–250 kcmil

5x5 hub cover plate

UEHT3R2302UCH

5

200

4

2

OH/UG

Horn

3/8-inch stud

#8–250 kcmil

5x5 hub cover plate

UEHT2R2302UCH

200

4

2

UG

Horn

#6–350 kcmil

#8–250 kcmil

Solid top

UHI2R2332ACVCH

5

5

5

#8–250 kcmil

5

200

4

2

OH/UG

Horn

#6–350 kcmil

#8–250 kcmil

Hub opening

UHI2R2332TCVCH

200

4

4

UG

Horn

1/0–500 kcmil cu/al

#8–250 kcmil

Solid top

UHI4R2352ACVCH

5

200

4

2

OH/UG

Horn

#6–350 kcmil

#8–250 kcmil

5x5 hub cover plate

UHTT2R2332UCH

5

200

4

2

OH/UG

Horn

#6–350 kcmil

#8–250 kcmil

5x5 hub opening

UHT2R2332TCH

200

4

3

OH/UG

Horn

#6–350 kcmil

#8–250 kcmil

5x5 hub opening

UHT3R2332TCH

5

200

4

3

OH/UG

Horn

1/0–500 kcmil cu/al

#8–250 kcmil

5x5 hub cover plate

UHT3R2352UCH

200

4

4

OH/UG

Horn

1/0–500 kcmil cu/al

#8–250 kcmil

5x5 hub opening

UHT4R2352TCH

5

200

4

4

OH/UG

—

1/0–500 kcmil cu/al

#8–250 kcmil

5x5 hub cover plate

UT4R2352UFLCH

200

4

4

OH/UG

Horn

1/0–500 kcmil cu/al

#8–250 kcmil

5x5 hub cover plate

UHT4R2352UCH

200

5

2

OH/UG

Lever

1/0–500 kcmil cu/al

#6–350 kcmil

5x5 hub opening

UT2H52353TCH

5

200

4

2

OH/UG

Horn

#6–350 kcmil

#8–250 kcmil

5x5 hub cover plate

UHT2R2332UCH

200

4

2

OH/UG

—

#6–350 kcmil

#8–250 kcmil

3-5/16 hub opening

UT2R2332BCH

5

200

4

2

OH/UG

—

#6–350 kcmil

#8–250 kcmil

5x5 hub opening

UAT2R2332TCH 1

200

4

2

OH/UG

—

#6–350 kcmil

#8–250 kcmil

5x5 hub opening

UT2R2332TCH

5

200

4

2

OH/UG

—

#6–350 kcmil

#8–250 kcmil

5x5 hub opening

U2R2332TCPLCH

5

200

4

2

OH/UG

—

#6–350 kcmil

#8–250 kcmil

5x5 hub cover plate

U2R2332UCPLCH

200

4

2

OH/UG

Horn

#6–350 kcmil

#8–250 kcmil

5x5 hub opening

U2R2332TDQCH

200

4

2

OH/UG

—

#6–350 kcmil

#8–250 kcmil

5x5 hub cover plate

UT2R2332UCH

200

4

3

OH/UG

Horn

#6–350 kcmil

#8–250 kcmil

Large 5X5 hub opening

U3R2332TDQCH

5

5
5

Notes
1 Aluminum enclosure.

5

For dimensions, see Pages V1-T5-23 and V1-T5-24.

V1-T5-20

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Metering Products
Multiple Position Horizontal Ganged Sockets

UT2R1121BCH

5.3

Horizontal Design—Multi Position Ringless, continued
Connections

Ampere
Rating

Jaws

Position

Service

Bypass

Line

200

4

3

OH/UG

Lever

1/0–500 kcmil cu/al

5

Load

Opening, Hub or
Closure Plate

Catalog Number

#6–350 kcmil

5x5 hub opening

UT3H42353TCH

200

5

3

OH/UG

Lever

1/0–500 kcmil cu/al

#6–350 kcmil

5x5 hub opening

UT3H52353TCH

200

7

3

OH/UG

Lever

1/0–500 kcmil cu/al

#6–350 kcmil

5x5 hub cover plate

UT3H72353UHLCH

200

4

3

OH/UG

—

#6–350 kcmil

#8–250 kcmil

5x5 hub opening

UT3R2332TCH

200

4

3

OH/UG

—

#6–350 kcmil

#8–250 kcmil

5x5 hub cover plate

UT3R2332UCH

200

4

3

OH/UG

—

1/0–500 kcmil cu/al

#8–250 kcmil

5x5 hub opening

UT3R2352TCH

200

4

4

OH/UG

—

1/0–500 kcmil cu/al

#8–250 kcmil

5x5 hub opening

UT4R2352TCH

200

4

5

OH/UG

Horn

(2) 1/0–500 kcmil cu/al #8–250 kcmil

5x5 hub opening (in two places)

UHT5R2392TTCH

200

4

5

OH/UG

—

(2) 1/0–500 kcmil cu/al #8–250 kcmil

5x5 hub opening (in two places)

UT5R2392TTCH

200

7

5

OH/UG

Lever

Dual 1/0–500 kcmil

(2) 5X5 hub closure plates

UT5H72393UUHLCH

200

4

6

OH/UG

Horn

(2) 1/0–500 kcmil cu/al #8–250 kcmil

#6–350 kcmil

5x5 hub opening (in two places)

UHT6R2392TTCH

200

4

6

OH/UG

—

(2) 1/0–500 kcmil cu/al #8–250 kcmil

5x5 hub opening (in two places)

UT6R2392TTCH

200

4

6

OH/UG

—

(2) 1/0–500 kcmil cu/al #8–250 kcmil

5x5 closure plate (in two places)

UT6R2392UUFLCH

200

7

6

OH/UG

Lever

Dual 1/0–500 kcmil

5x5 closure plate (in two places)

UT6H72393UUHLCH

200

4

6

OH/UG

Horn

(2) 1/0–500 kcmil cu/al #8–250 kcmil

5x5 hub opening (in two places)

UHT6R2392TTCH

150

4

2

OH/UG

Horn

#6–350 kcmil

#8–250 kcmil

3-5/16 hub opening

U2R5432BDQCH

150

4

5

OH/UG

—

#6–350 kcmil

#8–250 kcmil

3-5/16 hub opening (in two places)

UT5R5632BCH

100

4

6

OH/UG

—

#6–350 kcmil

#8–2/0 cu/al

3-5/16 hub opening

UT6R1131BCH

100

4

2

OH/UG

Horn

#6–250 kcmil

#8–2/0 cu/al

5x5 hub opening

1004426ACH

100

4

2

OH/UG

Horn

#6–250 kcmil

#8–2/0 cu/al

3-5/16 hub opening

1008951CH

100

4

3

OH/UG

Horn

#6–250 kcmil

#8–2/0 cu/al

3-5/16 hub opening

1008952CH

100

4

2

OH/UG

Horn

#6–250 kcmil

#8–2/0 cu/al

3-5/16 hub cover plate

1009693CH

100

4

3

OH/UG

Horn

#6–250 kcmil

#8–2/0 cu/al

3-5/16 hub cover plate

1009694CH

100

4

4

OH/UG

Horn

#6–250 kcmil

#8–2/0 cu/al

3-5/16 hub cover plate

1009695CH

100

4

5

OH/UG

Horn

#6–250 kcmil

#8–2/0 cu/al

3-5/16 hub cover plate

1009696CH

100

4

6

OH/UG

—

#6–350 kcmil

#8–2/0 cu/al

3-5/16 hub cover plate

UATZ6R1131CFLCH 1

100

4

2

OH/UG

Horn

#6–250 kcmil

#8–2/0 cu/al

3-5/16 hub opening

UBH2R1121BCH

100

4

3

OH/UG

Horn

#6–250 kcmil

#8–2/0 cu/al

3-5/16 hub opening

UBH3R1121BCH

100

4

4

OH/UG

Horn

#6–250 kcmil

#8–2/0 cu/al

3-5/16 hub opening

UBH4R1121BCH

100

4

2

OH/UG

Horn

#6–250 kcmil

#8–2/0 cu/al

3-5/16 hub opening

UHT2R1121BCH

100

4

4

OH/UG

—

#6–250 kcmil

#8–2/0 cu/al

3-5/16 hub opening

UT4R1121BCH

100

4

4

OH/UG

—

#6–250 kcmil

#8–2/0 cu/al

3-5/16 closure plate

UT4R1121CCH

100

4

4

OH/UG

Horn

#6–250 kcmil

#8–2/0 cu/al

3-5/16 hub opening

UHT4R1121BCH

100

4

5

OH/UG

Horn

#6–250 kcmil

#8–2/0 cu/al

3-5/16 hub opening

UHT5R1121BCH

100

4

5

OH/UG

—

#6–250 kcmil

#8–2/0 cu/al

3-5/16 hub opening

UT5R1121BCH

100

4

5

OH/UG

—

#6–250 kcmil

#8–2/0 cu/al

3-5/16 closure plate

UT5R1121CCH

100

4

2

OH/UG

—

#6–250 kcmil

#8–2/0 cu/al

3-5/16 hub opening

UT2R1121BCH

100

4

2

OH/UG

—

#6–250 kcmil

#8–2/0 cu/al

3-5/16 closure plate

UT2R1121CCH

100

4

2

OH/UG

Horn

#6–250 kcmil

#8–2/0 cu/al

3-5/16 closure plate

UHT2R1421CCH

100

4

2

OH/UG

—

#6–250 kcmil

#8–2/0 cu/al

3-5/16 hub opening
3-5/16 hub cover plate

UT2R1421BCH

100

4

3

OH/UG

Horn

#6–250 kcmil

#8–2/0 cu/al

3-5/16 hub opening

UHT3R1121BCH

100

4

3

OH/UG

—

#6–250 kcmil

#8–2/0 cu/al

3-5/16 hub opening

UT3R1121BCH

#6–350 kcmil

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

Notes
1 Aluminum enclosure.

5

For dimensions, see Pages V1-T5-23 and V1-T5-24.

5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-21

5.3

Metering Products
Multiple Position Horizontal Ganged Sockets

5

Horizontal Design—Multi Position Ring Type

5

Ampere
Rating

Jaws

Position

Service

Bypass

Line

Load

Opening, Hub or
Closure Plate

Catalog Number

5

200

4

2

OH/UG

—

1/0–500 kcmil cu/al

#8–250 kcmil

5x5 hub opening

U2R2352TCRCH

200

4

2

OH/UG

—

#6–350 kcmil

#8–250 kcmil

5x5 hub cover plate

URT2R2332UCH

5

200

5

4

OH/UG

—

1/0–500 kcmil cu/al

#8–250 kcmil

Large 5x5 hub opening

U4R2352TCRCH

125

5

2

OH

—

#8–350 kcmil

#8–2/0 cu/al

Hub opening

U2V1031BCRCH 1

5

125

5

3

OH

—

#8–350 kcmil

#8–2/0 cu/al

Hub opening

U3V1031BCRCH 1

5

100

5

2

OH/UG

—

#6–250 kcmil

#8–2/0 cu/al

3-5/16 opening

U2R1121BCRCH

100

5

3

OH/UG

—

#6–250 kcmil

#8–2/0 cu/al

3-5/16 opening

U3R1121BCRCH

100

5

4

OH/UG

—

#6–250 kcmil

#8–2/0 cu/al

3-5/16 opening

U4R1121BCRCH

100

5

5

OH/UG

—

#6–250 kcmil

#8–2/0 cu/al

3-5/16 opening

U5R1121BCRCH

5
5

Connections

Notes
1 Vertical gang.

5

For dimensions, see Pages V1-T5-23 and V1-T5-24.

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
V1-T5-22

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Metering Products
Multiple Position Horizontal Ganged Sockets

5.3

Dimensions

5

Approximate Dimensions in Inches (mm)

5
Horizontal Design—Multi Position Ringless

Horizontal Design—Multi Position Ringless, continued

Catalog Number

Height

Width

Depth

Catalog Number

Height

Width

Depth

1004401BCH

14.13 (358.9)

24.31 (617.5)

5.38 (136.7)

UT3R2332TCH

14.13 (358.9)

32.47 (824.7)

5.38 (136.7)

1004404BCH

14.13 (358.9)

32.47 (824.7)

5.38 (136.7)

UT3R2332UCH

14.13 (358.9)

32.47 (824.7)

5.38 (136.7)

1004418ACH

14.13 (358.9)

24.31 (617.5)

5.38 (136.7)

UT3R2352TCH

14.13 (358.9)

40.63 (1032.0)

5.38 (136.7)

1006737BCH

14.13 (358.9)

24.31 (617.5)

5.38 (136.7)

UT4R2352TCH

14.13 (358.9)

40.63 (1032.0)

5.38 (136.7)

1007700CH

14.13 (358.9)

24.31 (617.5)

5.38 (136.7)

UHT5R2392TTCH

14.13 (358.9)

54.78 (1391.4)

5.38 (136.7)

1007701CH

14.13 (358.9)

32.47 (824.7)

5.38 (136.7)

UT5R2392TTCH

14.13 (358.9)

54.78 (1391.4)

5.38 (136.7)

1008842CH

14.13 (358.9)

24.31 (617.5)

5.38 (136.7)

UT5H72393UUHLCH

29.56 (750.8)

72.15 (1832.6)

6.00 (152.4)

1008843CH

14.13 (358.9)

32.47 (824.7)

5.38 (136.7)

UHT6R2392TTCH

14.13 (358.9)

62.94 (1598.7)

5.38 (136.7)

1008844CH

14.13 (358.9)

40.63 (1032.0)

5.38 (136.7)

UT6R2392TTCH

14.13 (358.9)

62.94 (1598.7)

5.38 (136.7)

1008958CH

14.13 (358.9)

24.31 (617.5)

5.38 (136.7)

UT6R2392UUFLCH

14.13 (358.9)

62.94 (1598.7)

5.38 (136.7)

1008959CH

14.13 (358.9)

32.47 (824.7)

5.38 (136.7)

UT6H72393UUHLCH

23.56 (598.4)

83.28 (2115.3)

6.00 (152.4)

1008960CH

14.13 (358.9)

40.63 (1032.0)

5.38 (136.7)

UHT6R2392TTCH

14.13 (358.9)

62.94 (1598.7)

5.38 (136.7)

1009579ACH

14.13 (358.9)

54.78 (1391.4)

5.38 (136.7)

U2R5432BDQCH

14.13 (358.9)

20.16 (512.1)

5.38 (136.7)

U4R2352TDQCH

14.13 (358.9)

40.63 (1032.0)

5.38 (136.7)

UT5R5632BCH

14.13 (358.9)

48.63 (1235.2)

5.38 (136.7)

U5R2392TTDQCH

14.13 (358.9)

62.94 (1598.7)

5.38 (136.7)

UT6R1131BCH

14.13 (358.9)

56.93 (1446.0)

4.50 (114.3)

U6R2392TTDQCH

14.13 (358.9)

62.94 (1598.7)

5.38 (136.7)

1004426ACH

14.13 (358.9)

24.31 (617.5)

4.50 (114.3)

UBH4R2352TCH

14.13 (358.9)

40.63 (1032.0)

5.38 (136.7)

1008951CH

14.13 (358.9)

24.31 (617.5)

4.50 (114.3)

UBH2R2332TCH

14.13 (358.9)

24.31 (617.5)

5.38 (136.7)

1008952CH

14.13 (358.9)

32.47 (824.7)

4.50 (114.3)

UBH3R2332TCH

14.13 (358.9)

32.47 (824.7)

5.38 (136.7)

1009693CH

14.13 (358.9)

24.16 (613.7)

5.38 (136.7)

UEHT4R2302UCH

14.13 (358.9)

40.63 (1032.0)

5.38 (136.7)

1009694CH

14.13 (358.9)

32.31 (820.7)

5.38 (136.7)

UEHT3R2302UCH

14.13 (358.9)

32.47 (824.7)

5.38 (136.7)

1009695CH

14.13 (358.9)

49.94 (1268.5)

5.38 (136.7)

UEHT2R2302UCH

14.13 (358.9)

24.31 (617.5)

5.38 (136.7)

1009696CH

14.13 (358.9)

48.63 (1235.2)

5.38 (136.7)

UHI2R2332ACVCH

14.13 (358.9)

24.31 (617.5)

5.38 (136.7)

UATZ6R1131CFLCH

14.13 (358.9)

56.94 (1446.3)

4.50 (114.3)

UHI2R2332TCVCH

14.13 (358.9)

24.31 (617.5)

5.38 (136.7)

UBH2R1121BCH

14.13 (358.9)

24.94 (633.5)

4.50 (114.3)

UHI4R2352ACVCH

14.13 (358.9)

40.63 (1032.0)

5.38 (136.7)

UBH3R1121BCH

14.13 (358.9)

32.47 (824.7)

4.50 (114.3)

UHTT2R2332UCH

14.13 (358.9)

24.31 (617.5)

5.38 (136.7)

UBH4R1121BCH

14.13 (358.9)

40.63 (1032.0)

4.50 (114.3)

UHT2R2332TCH

14.13 (358.9)

24.31 (617.5)

5.38 (136.7)

UHT2R1121BCH

14.13 (358.9)

24.31 (617.5)

4.50 (114.3)

UHT3R2332TCH

14.13 (358.9)

32.94 (836.7)

5.38 (136.7)

UT4R1121BCH

14.13 (358.9)

40.63 (1032.0)

4.50 (114.3)

UHT3R2352UCH

14.13 (358.9)

32.47 (824.7)

5.38 (136.7)

UT4R1121CCH

14.13 (358.9)

40.63 (1032.0)

4.50 (114.3)

UHT4R2352TCH

14.13 (358.9)

40.63 (1032.0)

5.38 (136.7)

UHT4R1121BCH

14.13 (358.9)

40.63 (1032.0)

4.50 (114.3)

UT4R2352UFLCH

14.13 (358.9)

40.63 (1032.0)

5.38 (136.7)

UHT5R1121BCH

14.13 (358.9)

48.78 (1239.0)

4.50 (114.3)

UHT4R2352UCH

14.13 (358.9)

40.63 (1032.0)

5.38 (136.7)

UT5R1121BCH

14.13 (358.9)

48.78 (1239.0)

4.50 (114.3)

UT2H52353TCH

23.56 (598.4)

32.78 (832.6)

6.00 (152.4)

UT5R1121CCH

14.13 (358.9)

48.78 (1239.0)

4.50 (114.3)

UHT2R2332UCH

14.13 (358.9)

24.31 (617.5)

5.38 (136.7)

UT2R1121BCH

14.13 (358.9)

24.31 (617.5)

4.50 (114.3)

14.13 (358.9)

24.31 (617.5)

5.38 (136.7)

UT2R1121CCH

14.13 (358.9)

24.31 (617.5)

4.50 (114.3)

UT2R2332BCH
1

14.13 (358.9)

24.31 (617.5)

5.38 (136.7)

UHT2R1421CCH

14.13 (358.9)

20.16 (512.1)

5.38 (136.7)

UT2R2332TCH

14.13 (358.9)

24.31 (617.5)

5.38 (136.7)

UT2R1421BCH

14.13 (358.9)

20.16 (512.1)

5.38 (136.7)

U2R2332TCPLCH

14.13 (358.9)

24.31 (617.5)

5.38 (136.7)

UHT3R1121BCH

14.13 (358.9)

32.47 (824.7)

4.50 (114.3)

U2R2332UCPLCH

14.13 (358.9)

24.31 (617.5)

5.38 (136.7)

UT3R1121BCH

14.13 (358.9)

32.47 (824.7)

4.50 (114.3)

U2R2332TDQCH

14.13 (358.9)

24.31 (617.5)

5.38 (136.7)

UT2R2332UCH

14.13 (358.9)

24.31 (617.5)

5.38 (136.7)

Note
1 Aluminum enclosure.

U3R2332TDQCH

14.13 (358.9)

32.47 (824.7)

5.38 (136.7)

UT3H42353TCH

23.56 (598.4)

43.91 (1115.3)

6.00 (152.4)

UT3H52353TCH

23.56 (598.4)

43.91 (1115.3)

6.00 (152.4)

UT3H72353UHLCH

23.56 (598.4)

43.91 (1115.3)

5.38 (136.7)

UAT2R2332TCH

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

V1-T5-23

5.3
5
5
5

Metering Products
Multiple Position Horizontal Ganged Sockets

Approximate Dimensions in Inches (mm)

Horizontal Design—Multi Position Ring Type
Catalog Number

Height

Width

Depth

U2R2352TCRCH

14.13 (358.9)

24.31 (617.5)

5.38 (136.7)

URT2R2332UCH

14.13 (358.9)

24.31 (617.5)

5.38 (136.7)

5

U4R2352TCRCH

14.13 (358.9)

48.00 (1219.2)

5.38 (136.7)

U2V1031BCRCH 1

8.00 (203.2)

25.63 (650.9)

4.38 (111.1)

5

U3V1031BCRCH 1

8.00 (203.2)

35.88 (911.2)

4.38 (111.1)

U2R1121BCRCH

14.13 (358.9)

28.00 (711.2)

4.50 (114.3)

5

U3R1121BCRCH

14.13 (358.9)

38.00 (965.2)

4.50 (114.3)

5

U4R1121BCRCH

14.13 (358.9)

48.00 (1219.2)

4.50 (114.3)

U5R1121BCRCH

14.13 (358.9)

58.00 (1473.2)

4.50 (114.3)

5

5

Note
1 Vertical gang.

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
V1-T5-24

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Metering Products
Instrument Rated Sockets

Instrument Rated Sockets

5.4

Contents
Description
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page
V1-T5-26
V1-T5-26

5
5
5
5
5
5
5
5
5
5
5

Product Description
●

●
●

●

●
●

●

5

Available in 6, 7, 8 and
13 terminal designs
20A ratings standard
Multiple service designs
available (overhead,
underground, overhead/
underground)
Multiple hub opening
and closure plate
sizes available
600 Vac rated
Single cover/dual
cover availability
Provisional test switches
and factory-installed test
switch designs available

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-25

5.4
5
5

Metering Products
Instrument Rated Sockets

Product Selection
USTS132CCH

Instrument Rated Sockets
Ampere
Rating

Jaws

Service

Opening, Hub
or Closure Plate

Catalog
Number

20

13 terminal

UG

Solid top

USTH131A123CH

5

20

13 terminal

OH/UG

3-5/16 hub cover plate

USTS131B102CH

5

20

13 terminal

OH/UG

3-5/16 hub cover plate

USTS132B101CH

20

13 terminal

OH/UG

3-5/16 hub cover plate

USTS132CCH

5

20

13 terminal

OH/UG

1-inch bolt-on hub

1008694ACH

20

8 terminal

OH/UG

1-inch bolt-on hub

1008695ACH

5

20

13 terminal

N/A

N/A

1007003BCH

20

13 terminal

Solid top and bottom

Solid top

1007003CCH

5

20

13 terminal

OH/UG

3-5/16 hub cover plate

USTL131C207CH

20

13 terminal

OH/UG

Hub opening

USTS131BCH

5

20

13 terminal

OH/UG

1-1/4-inch bolt-on hub

USTS131L143CH

20

13 terminal

N/A

N/A

USTS132BCH

20

6 terminal

OH/UG

Hub opening

USTS61B138CH

5

5
5

20

6 terminal

OH/UG

Hub opening

UST61BCH

20

8 terminal

OH/UG

Hub opening

USTS82B166CH

20

8 terminal

N/A

Solid top and bottom

1007361BCH

N/A

N/A

N/A

N/A

1008539CH

5

20

13 terminal

OH/UG

3-5/16 hub cover plate

UASTS131C226CH

20

13 terminal

OH

3-5/16 hub cover plate

1004671CH

5

20

7 terminal

OH

3-5/16 hub cover plate

ULTS131CCH

20

6 terminal

UG

Solid top

STL61A433CH

20

13 terminal

UG

Solid top

STL131A120CH

5

5
5

Dimensions

5

Approximate Dimensions in Inches (mm)

5

Instrument Rated Sockets
Catalog Number

Height

Width

Depth

5

USTH131A123CH

20.00 (304.8)

12.00 (304.8)

4.36 (110.7)

USTS131B102CH

20.00 (304.8)

12.00 (304.8)

4.36 (110.7)

5

USTS132B101CH

20.00 (304.8)

12.00 (304.8)

4.36 (110.7)

5

USTS132CCH

20.00 (304.8)

12.00 (304.8)

4.36 (110.7)

1008694ACH

20.00 (304.8)

12.00 (304.8)

4.36 (110.7)

5

1008695ACH

20.00 (304.8)

12.00 (304.8)

4.36 (110.7)

1007003BCH

N/A

N/A

N/A

5

1007003CCH

16.50 (419.1)

14.00 (355.6)

3.50 (88.9)

USTL131207CH

20.00 (304.8)

12.00 (304.8)

4.35 (110.5)

5

USTS131BCH

20.00 (304.8)

12.00 (304.8)

4.35 (110.5)

USTS131L143CH

20.00 (304.8)

12.00 (304.8)

4.35 (110.5)

5

USTS132BCH

N/A

N/A

N/A

5

USTS61B138CH

20.00 (304.8)

12.00 (304.8)

4.35 (110.5)

UST61BCH

20.00 (304.8)

12.00 (304.8)

4.35 (110.5)

5

USTS82B166CH

20.00 (304.8)

12.00 (304.8)

4.35 (110.5)

1007361BCH

16.50 (419.1)

14.00 (355.6)

3.50 (88.9)

5

1008539CH

N/A

N/A

N/A

UASTS131C226CH

20.00 (304.8)

12.00 (304.8)

4.35 (110.5)

5

1004671CH

17.00 (431.8)

10.00 (254.0)

5.00 (127.0)

ULTS131CCH

22.00 (558.8)

12.00 (304.8)

4.94 (125.5)

5
V1-T5-26

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Metering Products
Residential Pedestals

Residential Pedestals

5.5

Contents
Description
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page
V1-T5-28
V1-T5-28

5
5
5
5
5
5
5
5
5
5
5

Product Description
●

●

●

●

●

5

Available in 100A, 200A,
300A and 320A designs
Available in 4- or 5-jaw
configurations
Underground service
design is standard
Bypass options (lever,
horn) are available
Solid top designs

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-27

5.5
5
5

Metering Products
Residential Pedestals

Product Selection
UHTRP242363CH

5
5

Residential Pedestals
Connections

Ampere
Rating

Jaws

Service

Bypass

Line

Load

Opening, Hub or
Closure Plate

Catalog Number

Solid top

1008847CH

320

4

UG

—

3/8-inch studs

3/8-inch studs

320

4

UG

Lever

#6–350 kcmil line and line neutral

2/0–250 kcmil load and load neutral Solid top

300

4

UG

Lever

#6–350 kcmil line and line neutral

2/0–250 kcmil load and load neutral Solid top

5

200

4

UG

Horn

4/0 compression (line) 2/0
compression (neutral)

#6–250 kcmil load and load neutral Solid top

1006388CH

5

200

4

UG

Horn

#8–350 kcmil

#8–350 kcmil

Solid top

UHTRP242363CH

200

4

UG

Horn

#6–350 kcmil line and line neutral

#6–250 kcmil load neutral

Solid top

1008846CH

5

200

4

UG

Horn

#6–350 kcmil line and line neutral

#6–250 kcmil load neutral

N/A

1008961CH

5

200

5

N/A

N/A

N/A

N/A

N/A

1008966CH

200

4

UG

—

#6–350 kcmil line and line neutral

#6–350 kcmil load and load neutral Solid top

1009264CH

5

200

4

UG

—

4/0 compression (line) 2/0
compression (neutral)

#6–350 kcmil load and load neutral Solid top

1009265CH

5

100

4

UG

—

#6–350 kcmil line and line neutral

#6–250 kcmil load neutral

1009078CH

5

5

Pedestal Extension Kits

5

Connections
Line

Load

Catalog Number

5

Pedestal extension kit for 1008846CH

Pedestal extension kit for 1008846CH

1009021CH
1009022CH

5
5

1009026CH

Dimensions

5

Approximate Dimensions in Inches (mm)

5

Residential Pedestals

5

Catalog Number

Height

Width

Depth

1008847CH

58.00 (1473.2)

12.97 (329.4)

4.93 (125.2)

1009017CH 1

63.00 (1600.2)

12.96 (329.2)

4.93 (125.2)

1006388CH

61.00 (1549.4)

8.96 (227.6)

4.93 (125.2)

UHTRP242363CH

62.63 (1590.8)

8.97 (227.8)

4.94 (125.5)

1008846CH

70.00 (1778.0)

11.00 (279.4)

6.00 (152.4)

5

1008961CH

69.93 (1776.2)

N/A

6.00 (152.4)

5

1008966CH

N/A

N/A

N/A

1009264CH

74.00 (1879.6)

8.96 (227.6)

4.93 (125.2)

1009265CH

74.00 (1879.6)

8.97 (227.8)

4.94 (125.5)

1009078CH

69.93 (1776.2)

11.00 (279.4)

6.00 (152.4)

5
5

5
5
5
5
5
5

Pedestal Extension Kits
Catalog Number

Height

Width

Depth

1009021CH

18.00 (457.2)

11.00 (279.4)

6.00 (152.4)

1009022CH

18.00 (457.2)

12.96 (329.2)

4.93 (125.2)

1009026CH

30.00 (762.0)

12.96 (329.2)

4.93 (125.2)

Note
1 200A breakers.

5
V1-T5-28

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Solid top

1009017CH 1

Metering Products
Accessories and Cross-Reference

5.6

Product Description

5

This section will help you
better understand the
features and benefits of the
125A and 200A Eaton
designed meter socket.

5
5
5

Features and Benefits
Construction Features

5

200A Ringless Block Assembly With Horn Bypass

5
5
5
1. High strength, glass-filled
meter block assembly,
lay-in connectors with
captive slide nut and
screw.

5
5

3. Extruded neutral lug
with integral triplex
ground and quadplex
ground provision.

5
5
5
5

2. 100% plated copper
alloy meter jaw with
reinforcing spring clip
and meter guide.

4. Bridge and meter
supports are 100%
zinc chromate plated.

5. Fifth terminal locating
hole in 9 o’clock position.

9. Extra rigid meter support
for ringless sockets.

6. Triplex ground is a
standard feature.

10. Optional, integral horn
bypass extruded on slide
nut. Horn is ribbed for
secure attachment to
utility bypass jumpers.
Field-installable horn
bypass kit available.

7. Quadplex ground
provision.
8. Durable “four-point”
bridge mounting
(2 top, 2 bottom).

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-29

5.6
5
5

Metering Products
Accessories and Cross-Reference

Product Selection
Meter Socket Accessories

5

Description

Part Number

5

Hub closure plate meter socket accessories

ARP00002CHB

Clam shell hub closure plate meter socket accessories

ARP00002CHBCS

5

1-inch hub closure plate meter socket accessories

ARP00003CH1

Clam shell 1-inch hub closure plate—small opening

ARP00003CH1CS

5

1-1/4-inch hub closure plate meter socket accessories

ARP00004CH12

Clam shell 1-1/4-inch hub closure plate—small opening

ARP00004CH12CS

1-1/2-inch hub closure plate meter socket accessories

ARP00005CH15

5

Clam shell 1-1/2-inch hub closure plate—small opening

ARP00005CH15CS

2-inch hub closure plate meter socket accessories

ARP00006CH2

5

2-1/2-inch hub for meter socket accessories

ARP00007CH25

Clam shell 2-1/2-inch hub for meter socket accessories

ARP00007CH25CS

5

Aluminum hub closure plate for single sockets

ARP00008CH

5

Hub adapter from large opening to small opening

ARP00015CHAP

Large hub cover plate

ARP00016CHB

2-inch hub with large diameter opening

ARP00017CH2

2.5-inch hub with large diameter opening

ARP00018CH25

5

3-inch hub

ARP00019CH3

5

3-1/2-inch hub for meter sockets

ARP00020CH35

4-inch hub

ARP00021CH4

5

Screw sealing ring for single meter sockets

ARP00027CH

Fifth jaw kit

ARP00035CHJ

5

#6–350 kcmil lug kit for single sockets—3/8-inch stud

ARP00119CH

5

#4–600 kcmil connector for single position meter sockets

ARP00129CH

Fifth jaw for bolt on meter

ARP00326CH

5

#6–350 kcmil double barrel lug kit

ARP00427CH

Neutral Insulating Kit

ARP00759CH

5

100A meter socket horn cap assembly kit

ARP00777CH

Fifth jaw kit for 320A offset socket

ARP00862CH

HQ anti-inversion clip for single meter sockets

ARP00984CH

5

Fifth jaw for Chicago and Wisconsin pedestal

ARP01085CH

350 kcmil BNS cap assembly kit for meter sockets

ARP01226CH

5

Right hand block assembly with Z Bar

ARP01258CH

Left hand block assembly with Z Bar

ARP01414CH

Meter pack trough closure plate kit

ARP01565CH

2/0 connector kit for MBB and MBP socket breaker

ARP01612CH

5

5

5

5
5
5
5
5
5
5
5

V1-T5-30

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Metering Products
Accessories and Cross-Reference

5.6

Cross-Reference

5
5

Meter Sockets

5

Manufacturer
Eaton

Milbank

Description

Part Number

Part Number

125A, OH/UG, ringless, triplex ground, hub opening

UTRS101BE

U7487-RL-TG

125A, OH/UG, ringless, triplex ground, hub cover plate

UTRS101CE

U7487-XL-TG

125A, OH/UG, ringless, triplex ground, hub opening, horn bypass

UHTRS101BE

U7487-RL-TG-KK

125A, OH/UG, ringless, triplex ground, hub cover plate, horn bypass

UHTRS101CE

U7487-XL-TG-KK

125A, OH/UG, ringless, triplex ground, hub opening, fifth terminal

UTRS101BCH + MSR5TK

U7487-RL-TG-5T

125A, OH/UG, ringless, triplex ground, hub cover plate, fifth terminal

UTRS101CE + MSR5TK

U7487-XL-TG-5T

125A, OH/UG, ringless, triplex ground, hub opening, horn bypass, fifth terminal

UHTRS101BCH + MSR5TK

U7487-RL-TG-KK-5T

125A, OH/UG, ringless, triplex ground, hub cover plate, horn bypass, fifth terminal

UGHTRS101CE + MSR5TK

U7487-XL-TG-KK-5T

200A, OH, ringless, triplex ground, hub opening

UTRS202BCH

U7021-RL-TG

200A, OH, ringless, triplex ground, hub cover plate

UTRS202CCH

U7021-XL-TG

200A, OH, ringless, triplex ground, hub opening, horn bypass

UHTRS202BCH

U7021-RL-TG-KK

200A, OH, ringless, triplex ground, hub cover plate, horn bypass

UHTRS202CCH

U7021-RL-TG-KK

200A, OH, ringless, triplex ground, hub opening, fifth terminal

UGTRS202BCH

U7021-RL-TG-5T

200A, OH, ringless, triplex ground, hub cover plate, fifth terminal

UGTRS202CCH

U7021-XL-TG-5T

200A, OH, ringless, triplex ground, hub opening, horn bypass, fifth terminal

UGHTRS202BCH

U7021-RL-TG-KK-5T

200A, OH, ringless, triplex ground, hub cover plate, horn bypass, fifth terminal

UGHTRS202CCH

U7021-RL-TG-KK-5T

200A, OH/UG, ringless, triplex ground, hub opening, 250 kcmil lugs

UTRS212BCH

No cross (no 250 kcmil lugs)

200A, OH/UG, ringless, triplex ground, hub cover plate, 250 kcmil lugs

UTRS212CCH

No cross (no 250 kcmil lugs)

200A, OH/UG, ringless, triplex ground, hub opening, horn bypass, 250 kcmil lugs

UHTRS212BCH

No cross (no 250 kcmil lugs)

200A, OH/UG, ringless, triplex ground, hub cover plate, horn bypass, 250 kcmil lugs

UHTRS212CCH

No cross (no 250 kcmil lugs)

200A, OH/UG, ringless, triplex ground, hub opening, fifth terminal, 250 kcmil lugs

UGTRS212BCH

No cross (no 250 kcmil lugs)

200A, OH/UG, ringless, triplex ground, hub cover plate, fifth terminal, 250 kcmil lugs

UGTRS212CCH

No cross (no 250 kcmil lugs)

200A, OH/ UG, ringless, triplex ground, hub opening, horn bypass, fifth terminal, 250 kcmil lugs

UGHTRS212BCH

No cross (no 250 kcmil lugs)

200A, OH/UG, ringless, triplex ground, hub cover plate, horn bypass, fifth terminal, 250 kcmil lugs

UGHTRS212CCH

No cross (no 250 kcmil lugs)

200A, OH/UG, ringless, triplex ground, hub opening, 350 kcmil lugs

UTRS213BE

U7040-RL-TG

200A, OH/UG, ringless, triplex ground, hub cover plate, 350 kcmil lugs

UTRS213CE

U7040-XL-TG

200A, OH/UG, ringless, triplex ground, hub opening, horn bypass, 350 kcmil lugs

UHTRS213BE

U7040-RL-TG-KK

200A, OH/UG, ringless, triplex ground, hub cover plate, horn bypass, 350 kcmil lugs

UHTRS213CE

U7040-XL-TG-KK

200A, OH/UG, ringless, triplex ground, hub opening, fifth terminal, 350 kcmil lugs

UGTRS213BE

U7040-RL-TG-5T

200A, OH/UG, ringless, triplex ground, hub cover plate, fifth terminal, 350 kcmil lugs

UGTRS213CE

U7040-XL-TG-5T

200A, OH/ UG, ringless, triplex ground, hub opening, horn bypass, fifth terminal, 350 kcmil lugs

UGHTRS213BE

U7040-RL-TG-KK-5T

200A, OH/UG, ringless, triplex ground, hub cover plate, horn bypass, fifth terminal, 350 kcmil lugs

UGHTRS213CE

U7040-XL-TG-KK-5T

200A, UG, ringless, triplex ground, solid top

UTRS223ACH

U1980-0-TG

200A, UG, ringless, triplex ground, solid top, horn bypass

UHTRS223ACH

U1980-0-TG-KK

200A, UG, ringless, triplex ground, solid top, fifth terminal

UGTRS223ACH

U1980-O-TG-5T

200A, UG, ringless, triplex ground, solid top, horn bypass, fifth terminal

UGHTRS223ACH

U1980-O-TG-KK-5T

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-31

5.6
5
5
5

Metering Products
Accessories and Cross-Reference

Lever Bypass
Manufacturer
Eaton

Milbank

Description

Part Number

Part Number
U9800-RL

200A, OH, lever bypass, 4 terminal, small hub opening

UTE4203BCH

200A, OH, lever bypass, 4 terminal, hub cover plate

UTH4203CCH

U9800-XL

200A, OH, lever bypass, 4 terminal, large hub opening

UTH4203TCH

U9800-R

5

200A, OH, lever bypass, 4 terminal, large hub cover plate

UTH4203UCH

U9800-X

5

200A, OH, lever bypass, 5 terminal, small hub opening

UTE5203BCH

U4550-RL

200A, OH, lever bypass, 5 terminal, hub cover plate

UTH5203CCH

U4550-XL

200A, OH, lever bypass, 5 terminal, large hub opening

UTH5203TCH

U9559-R

200A, OH, lever bypass, 5 terminal, large hub cover plate

UTH5203UCH

U9550-X

5

5
5
5

200A, OH, lever bypass, 7 terminal, small hub opening

UTE7203BCH

U4701-RL

200A, OH, lever bypass, 7 terminal, hub cover plate

UTH7203CCH

U4701-XL

200A, OH, lever bypass, 7 terminal, large hub opening

UTE7203TCH

U4701-R

5

200A, OH, lever bypass, 7 terminal, large hub cover plate

UTH7203UCH

U4701-X

200A, OH/UG, lever bypass, 4 terminal, small hub opening

UTE4213BCH

U9801-RL

5

200A, OH/UG, lever bypass, 4 terminal, hub cover plate

UTE4213CCH

U9801-XL

200A, OH/UG, lever bypass, 4 terminal, large hub opening

UTE4213TCH

U9801-R

5

200A, OH/UG, lever bypass, 4 terminal, large hub cover plate

UTH4213UCH

U9801-XL

5

200A, OH/UG, lever bypass, 4 terminal, large hub opening with adapter plate

UTE4213ZCH

U9801-RRL

200A, OH/UG, lever bypass, 4 terminal, large hub opening with adapter and cover plate

UTH4213YCH

U9801-RXL

5

200A, OH/UG, lever bypass, 5 terminal, small hub opening

UTE5213BCH

U4551-RL
U4551-XL

200A, OH/UG, lever bypass, 5 terminal, hub cover plate

UTE5213CCH

200A, OH/UG, lever bypass, 5 terminal, large hub opening

UTE5213TCH

U9551-R

200A, OH/UG, lever bypass, 5 terminal, large hub cover plate

UTH5213UCH

U9551-X

200A, OH/UG, lever bypass, 5 terminal, large hub opening with adapter plate

UTE5213ZCH

U9551-RRL or U4551-RRL

5

200A, OH/UG, lever bypass, 5 terminal, large hub opening with adapter and cover plate

UTH5213YCH

U9551-RXL or U4551-RXL

200A, OH/UG, lever bypass, 7 terminal, small hub opening

UTE7213BCH

U9701-RL or U4701-RL

5

200A, OH/UG, lever bypass, 7 terminal, hub cover plate

UTE7213CCH

U9701-XL or U4701-XL

5

200A, OH/UG, lever bypass, 7 terminal, large hub opening

UTE7213TCH

U9701-R or U4701-R

200A, OH/UG, lever bypass, 7 terminal, large hub cover plate

UTE7213UCH

U9701-RX or U4701-RX

5
5

5

200A, OH/UG, lever bypass, 7 terminal, large hub opening with adapter plate

UTE7213ZCH

U9701-RRL or U4701-RRL

200A, OH/UG, lever bypass, 7 terminal, large hub opening with adapter and cover plate

UTH7213YCH

U9701-RXL or U4701-RXL

5

320A, OH, lever bypass, 4 terminal, large hub opening

UTH4300TCH

U1079-R or U1797-R

320A, OH, lever bypass, 4 terminal, large hub cover plate

UTH4300UCH

U1079-X or U1797X

5

320A, OH/UG, lever bypass, 4 terminal, large hub opening

UTH4330TCH

U2448-R or U2124-R

5

320A, OH/UG, lever bypass, 4 terminal, large hub cover plate

UTH4330UCH

U2448-RX or U2124-RX

320A, OH, lever bypass, 7 terminal, large hub opening

UTH7300TCH

—

5

320A, OH, lever bypass, 7 terminal, large hub cover plate

UTH7300UCH

—

320A, OH/UG, lever bypass, 7 terminal, large hub opening

UTH7330TCH

U2120-R

320A, OH/UG, lever bypass, 7 terminal, large hub cover plate

UTH7330UCH

U2120-X

5
5
5
5
5
5

V1-T5-32

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Metering Products
Accessories and Cross-Reference

5.6

Accessories

5

Manufacturer
Eaton

Milbank

Description

Part Number

Part Number

Small hub cover plate

ARP00002CHB

A7551

1-inch hub

ARP00003CH1

A7514

1-1/4-inch hub

ARP00004CH12

A7515

1-1/2-inch hub

ARP00005CH15

A7516

2-inch hub

ARP00006CH2

A7517

2-1/2-inch hub

ARP00007CH25

A7518

3-inch hub

ARP00019CH3

A8110

3-1/2-inch hub

ARP00020CH35

A8111

4-inch hub

ARP00021CH4

A8112

Large to small hub opening adapter plate

ARP00015CHAP

S8324

Large hub cover plate

ARP00016CHB

S9064

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-33

5.7
5

Metering Products
Mechanical Lugs

Contents

Mechanical Lugs

Description

5

Mechanical Lugs

5
5
5
5
5
5
5
5
5
5
5
5
5

Product Description
●
●
●

Single lug
Extended tang single lug
Extended tang triple lug

●
●
●

Double lug
Extended tang double lug
Extended tang quadruple
lug

Product Selection

Dimensions
Approximate Dimensions in Inches (mm)

5

Mechanical Lugs

5

Description

Style Number

Style Number

Height

Single #14–#6 mechanical lug

ESL146

ESL146

2.50 (63.5)

8.25 (82.6)

3.50 (88.9)

Single #14–2/0 mechanical lug

ESL1420

ESL1420

2.50 (63.5)

10.50 (266.7)

3.50 (88.9)

Single #6–250 kcmil mechanical lug

ESL6250

ESL6250

2.50 (63.5)

10.50 (266.7)

3.50 (88.9)

5

Single #4–500 kcmil mechanical lug

ESL4500

ESL4500

2.50 (63.5)

10.50 (266.7)

3.50 (88.9)

5

Double #14–2/0 mechanical lug

EDL1420

EDL1420

3.50 (88.9)

4.00 (101.6)

3.50 (88.9)

Double #6–250 kcmil mechanical lug

EDL6250

EDL6250

3.50 (88.9)

3.75 (95.3)

4.50 (114.3)

5

Extended tang single lug #6–350 kcmil

EPBSL6350

EPBSL6350

2.50 (63.5)

8.25 (82.6)

3.50 (88.9)

Extended tang single lug 300–800 kcmil

EPBSL300800

EPBSL300800

2.50 (63.5)

10.50 (266.7)

3.50 (88.9)

5

Extended tang double lug #6–350 kcmil

EPBDL6350

EPBDL6350

3.50 (88.9)

4.50 (114.3)

5.50 (139.7)

5

Extended tang double lug 300–800 kcmil

EPBDL300800

EPBDL300800

3.00 (76.2)

10.50 (266.7)

5.50 (139.7)

Extended tang triple lug #6–350 kcmil

EPBTL6350

EPBTL6350

3.50 (88.9)

4.50 (114.3)

5.50 (139.7)

5

Extended tang triple lug 300–800 kcmil

EPBTL300800

EPBTL300800

2.50 (63.5)

10.00 (254.0)

5.75 (146.0)

Extended tang quadruple lug #6–350 kcmil

EPBQL6350

EPBQL6350

2.25 (57.2)

6.50 (165.1)

6.00 (152.4)

5

Extended tang quadruple lug 300–750 kcmil

EPBQL300800

EPBQL300800

4.25 (108.0)

8.50 (215.9)

8.50 (215.9)

Extended tang single lug #2–600 kcmil

EPBSL2600

EPBSL2600

2.50 (63.5)

8.25 (82.6)

3.50 (88.9)

Extended tang single lug 500–1000 kcmil

EPBSL5001000

EPBSL5001000

2.50 (63.5)

10.50 (266.7)

3.50 (88.9)

Extended tang triple lug #2–600 kcmil

EPBTL2600

EPBTL2600

2.25 (57.2)

6.50 (165.1)

6.00 (152.4)

5

5
5

Mechanical Lugs

5
5
5
V1-T5-34

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Width

Length

Metering Products
Communications Grounding Device (NEC 250.94)

5.8

Contents

Communication Grounding Device

Description

Page

Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

V1-T5-36
V1-T5-36

5
5
5
5
5
5
5
5
5
5

Product Description
This product is required per
the 2008 NEC Article 250.94
“Bonding for Other Systems.”
This product is applied
externally to residential
homes, so that
communications systems
devices such as satellite,
TV, cable and CATV can be
properly bonded at a single
point. This device has two
mounting holes that can be
used for easy installation.

Features, Benefits
and Functions

Product Selection

Communication Grounding
Device Features
●
Lay-in lug for ease
of installation
●
Four bonding terminals
●
Heavy-duty zinc-plated
steel screws included
●
Two mounting holes to
securely hold device
into place
●
For use with copper and
aluminum conductors

Communication Grounding Device

5
5
5

Wire Range
Bonding
Conductor

Ground
Electrode

Quantity

Catalog
Number

5

#14–#2–STR–SOL–CU
#12–#2–SRT–SOL–AL

#8–1/0–STR–SOL–CU/AL

(1) Clamshell

MSEGR2CS

5

#14–#2–STR–SOL–CU
#12–#2–SRT–SOL–AL

#8–1/0–STR–SOL–CU/AL

(10) Bulk pack

MSEGR2

5
5
5

Cover Features
●
Outdoor rated reinforced
glass polyester compound
●
Suitable for UV exposure
●
Paintable exterior, allowing
for matching of exterior of
home

5

Standards and
Certifications

5

●

5
5
5
5

ETL listed

5
5
5
5
5
5
Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-35

5.8
5
5

Metering Products
Communications Grounding Device (NEC 250.94)

Wiring Diagram
Installation and Configuration

5
5

Service Entrance Panel

5

Single Meter Socket

5
5
5
5

Communication
Grounding Device
(Top View)

5
5

Grounding Electrode
Conductor

5
5
5
5
5
5
5
5

Phone System Ground

Grounding
Electrode
Conductor

Communication Grounding Device
(Top view)

5

Mounting Holes
(Typical)

5
5

Satellite TV Ground

5
5
5
5
5
5
5

Coax Cable Ground

Dimensions
Approximate Dimensions in Inches (mm)

Communication Grounding Device
Catalog Number

Length

Width

Height

MSEGR2CS

0.75 (19.1)

3.90 (99.1)

1.20 (30.5)

MSEGR2

0.75 (19.1)

3.90 (99.1)

1.20 (30.5)

5
V1-T5-36

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Metering Products
Meter Breakers

5.9

Contents

Residential Meter Breakers

Description

Page

Residential Meter Breakers
Non-EUSERC Combination Service Entrance
Devices 100–200A Styles . . . . . . . . . . . . . . . . . .
Meets EUSERC Requirements Service Entrance
Devices 100–225A . . . . . . . . . . . . . . . . . . . . . . .
West Coast All-In-One Design. . . . . . . . . . . . . . . .
Mechanical Interlock Cover . . . . . . . . . . . . . . . . . .
House Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Commercial Safety Sockets. . . . . . . . . . . . . . . . . .
CH Style Renovation Solutions . . . . . . . . . . . . . . .
Aluminum Meter Breakers . . . . . . . . . . . . . . . . . .

V1-T5-39
V1-T5-48
V1-T5-59
V1-T5-65
V1-T5-75
V1-T5-83
V1-T5-86
V1-T5-87

5
5
5
5
5
5
5
5
5
5
5

Residential Meter Breakers
Product Description

Application Description

A meter breaker is service
entrance equipment that
consists of a single meter
socket and loadcenter (circuit
breaker distribution section)
or meter socket and main
breaker combined in one
enclosure. Sometimes called
Combos, All-in-Ones, Meter
Centers or Meter Mains,
these units are increasing in
popularity as the socket and
loadcenter or main breaker
are located in one location,
thus providing the contractor
with a labor and material
savings when installing.

In addition to residential
installations, meter breakers
are equally applicable for rural
service entrance, mobile
homes and construction site
temporary power. Meter
breakers are most often sold
in the western, southwestern
and southeastern United
States. The popularity of
meter breakers is continuing
to increase as more utilities
deregulate and pass the
responsibility of supplying
watthour meter sockets on
to the electrical contractor.

EUSERC/West Coast
(Page V1-T5-59)

Application Considerations
Eaton has the meter breaker
to meet your application,
offering:

CH and BR Styles
(Page V1-T5-76).

●
●
●
●

Non-EUSERC
EUSERC/West Coast
House panels
Commercial safety socket

Non-EUSERC
(Page V1-T5-39)
Eaton’s line of non-EUSERC
meter breakers are designed
for customers served by
utilities that are not members
of EUSERC.

Eaton’s line of EUSERC
required devices adhere to
the agreed upon standards.
EUSERC utilities are
predominately located in
the western United States,
but some eastern and
midwestern utilities are
also members. These units
can also be used in many
Non-EUSERC areas.
House Panels
(Page V1-T5-75)

Meter breaker device rated
at 300–400A. Applied in
EUSERC and non-EUSERC
areas.
Commercial Safety Sockets
(Page V1-T5-83)

●

●

●

●

●

●

●

●

●

●

Applied in EUSERC and
non-EUSERC service areas
and used in commercial
applications.

5

Features, Benefits
and Functions

●

●

●

Both Type BR and CH
branch circuit breaker
styles available
Meets latest NEC
wire bending space
requirements
Slotted sealing screws
at hub with sealing
provision provided
Surface units are supplied
with mounting tabs
Semi-flush units are
supplied with stucco flange
Meter socket ring
landing will accept
locking security rings
Overhead or underground
service
Fifth jaw can be installed in
the 3 o’clock or 9 o’clock
position
Semi-flush with nail flange
or surface mounting
Meter mounting and
underground pull sections
are utility sealable
Units are rated a minimum
of 10 kAIC; some units
are 22 kAIC
Numerous units supplied
with center keyhole for
ease of mounting
NEMA 3R rainproof
construction

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-37

5.9
5
5

Meter Breakers

Standards and Certifications
●

●

5

●

5

●

5

●

5

Metering Products

●

UL Specification 414
(socket)
UL File Number E52977
AEIC-EEI-NEMA Standards
(MSJ-7)
Meet EUSERC utility
requirements where noted
Documented seismic
qualified—UBC® and
CBC Title 24
UL Specification 67 (panel)

Technical Data
and Specifications
●

●

●

●

Ratings single-phase,
three-wire, 120/240 Vac
100–225A main breaker
and main lug types
10,000A rms symmetrical
short-circuit rating
Available kAIC ratings:
10k with BW breaker,
22k with CSR breaker
and 35k with CSH breaker

Consult TD.31F.01.T.E for
dimensions, wiring diagrams
and knockouts.

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
V1-T5-38

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Metering Products
Meter Breakers

5.9

Contents

Residential Meter Breakers

Description

Page

Residential Meter Breakers. . . . . . . . . . . . . . . . . .
Non-EUSERC Combination Service Entrance
Devices 100–200A Styles
Meets EUSERC Requirements Service Entrance
Devices 100–225A . . . . . . . . . . . . . . . . . . . . . . .
West Coast All-In-One Design. . . . . . . . . . . . . . . .
Mechanical Interlock Cover . . . . . . . . . . . . . . . . . .
House Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Commercial Safety Sockets . . . . . . . . . . . . . . . . .
CH Style Renovation Solutions . . . . . . . . . . . . . . .
Aluminum Meter Breakers . . . . . . . . . . . . . . . . . .

V1-T5-37

5
5
5

V1-T5-48
V1-T5-59
V1-T5-65
V1-T5-75
V1-T5-83
V1-T5-86
V1-T5-87

5
5
5
5
5

Standard Design Non-EUSERC Panel

5

Compact Design

5
5

Non-EUSERC Combination Service Entrance Devices
100–200A Styles
Product Description

Application Description

A device that may include a
meter socket, main breaker
and loadcenter section within
the same enclosure.

Eaton’s line of non-EUSERC
meter breakers are designed
for customers served by
utilities that are not members
of EUSERC.

●

●

Meter main = meter socket
and main breaker
Meter breaker = meter
socket, main breaker and
loadcenter section

5

Features, Benefits and Functions
Meter Mains and All-in-Ones
●
Single-phase, three-wire,
120/240 Vac,10 kAIC
●
Larger lay-in lugs and 3-inch
(76.2 mm) knockouts for
ease of installation
●
Box-type main lugs
included
●
Factory-installed neutral
●
Hub provisions on top
endwall. If hubs are
required, order “DS” style
●
Ring, ringless and ringless
with horn bypass styles
available
●
Ringless style, provided
with embossed covers and
security latch for utility
company lock
●
Padlockable device covers
provide additional measure
of safety and help prevent
tampering
●
NEMA 3R rainproof
construction

Meter Mains
●
Meter socket and
main breaker
●
Stainless steel latches on
meter compartments in
MBP types
●
No distribution section
included
All-in-Ones
●
Meter socket and
loadcenter distribution
section
●
Stainless steel latches on
meter compartments
●
Several designs with horn
bypass and fifth jaw
●
Center-fed main breaker,
lugs or provision
●
Uses Type BR 1-inch
(25.4 mm) wide branch
breakers
●
Special channel for top exit

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-39

5.9
5

Metering Products
Meter Breakers

Catalog Number Selection

MB 20 40 B 200 BT S

5
5
MB
MBE
CMB
CMBE

5
5

Meter Breaker Type
= 1-inch BR Type
= 1-inch BR Type—EUSERC
= 3/4-Inch (19.1 mm) CH Type
= 3/4-inch (19.1 mm) CH Type—
EUSERC

Spacing
Number of spaces
Poles
Maximum number of poles
Main
B = Main breaker included
P = Provision for main
L = Main lug

5
5

Amperes
Amperage of unit

5

D
CU
C
CR

Accessories/Modifications
= 5th jaw and horn bypass
= Copper
= Single cover compact design
= Two cover compact design

Mounting
S = Surface
F = Flush/stucco
Breaker Feed
BT = Bottom and top
B = Bottom only
T = Top only

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
V1-T5-40

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Metering Products
Meter Breakers

5.9

Product Selection

5

Note: See knockout drawings on Pages V1-T5-68 through V1-T5-74 for hub information.
Standard Design
Non-EUSERC Panel

5

Combination Service Entrance Devices—Non-EUSERC
Ampere
Rating

Bypass

Service

kAIC

Jaws

Distribution

Main

Branch
Breaker
Type

Page Numbers
Dimensions
Catalog
and Enclosure
Wiring
Knockout 1 Number
Shape 1

5
5

5

Ring Style Meter Mains (no distribution section included)

Compact Design

150

None

OH/UG

10

4

None

CSH2150

None

13

V1-T5-46

V1-T5-74

MBB150BTSCR

150

None

OH/UG

22

4

None

CSH2150

None

3

V1-T5-43

V1-T5-70

CMBB150BTS 67

200

None

OH/UG

10

4

None

CSH2200

None

13

V1-T5-46

V1-T5-74

MBB200BTSCR

200

None

OH/UG

2

4

None

Provision 45 None

3

V1-T5-43

V1-T5-70

CMBP200BTS 67

200

None

OH/UG

22

4

None

CSH2200

None

3

—

V1-T5-70

CMBB200BTS 67

CSH2150

None

13

V1-T5-46

V1-T5-74

MBB150BTSC 7

Ringless Meter Mains (no distribution section included)
150

None

OH/UG

10

4

None

8

200

None

OH/UG

10

4

None

CSH2200

None

9

V1-T5-47

V1-T5-74

MBB200BTS

200

None

OH/UG

10

4

None

CSH2200

None

13

V1-T5-46

V1-T5-74

MBB200BTSC 7

150

None

OH/UG

10

4

None

CSH2125

None

9

V1-T5-47

V1-T5-74

MBB150BTS

200

None

OH/UG

2

4

None

Provision 3

None

9

V1-T5-47

V1-T5-74

MBP200BTS 7

200

Horn

OH/UG

2

5

None

Provision 34 None

11

V1-T5-45

V1-T5-74

MBP200SD

200

Horn

OH/UG

2

5

None

Provision 34 None

9

V1-T5-47

V1-T5-74

MBP200BTSD

100

Horn

OH/UG

10

5

None

Provision

None

15

—

V1-T5-74

CHMMB100BTS

150

Horn

OH/UG

10

5

None

CSR2150

None

16

—

V1-T5-74

CHMMB150BTS

200

Horn

OH/UG

10

5

None

CSR2200

None

16

—

V1-T5-74

CHMMB200BTS

150

None

OH/UG

10

4

4/8

CSR

BR

—

—

—

MB48B150TSG

200

None

OH/UG

10

4

4/8

CSR

BR

—

—

—

MB48B200BTSG

200

Lever

OH/UG

22

4

8/16

CSR

BR

—

—

—

MBX816B200BTS

200

Lever

OH/UG

22

4

20/40

CSR

BR

—

—

—

MBX2040B200BTS

Notes
1 See Page V1-T5-68 for box details.
2 Per installed main breaker rating.
3 When a provision for main is provided, order one of the main breakers listed in Page V1-T5-43. Panels are dual labeled to accept
Types BW, CSR or CSH Main Breakers.
4 MCBK225 lug kit is needed for load side cable connection for Meter Mains. Please order separately.
5 When a provision for main is provided, order one of the main breakers listed in this table. Panels are labeled to accept Type CSR Main Breakers.
6 Copper bus.
7 One-piece cover on utility side, Florida approved.
8 Single cover design.
9 Xcel approved.

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-41

5.9
5
5
5
5

Metering Products
Meter Breakers

Note: See knockout drawings on Pages V1-T5-68 through V1-T5-74 for hub information.

Combination Service Entrance Devices—Non-EUSERC, continued
Ampere
Rating

Bypass

Service

kAIC

Jaws

Distribution

Main

Branch
Breaker
Type

Dimensions
and Enclosure
Shape 1

Page Numbers
Wiring

Knockout 1

Catalog
Number

CH

2

V1-T5-43

V1-T5-70

CMB24L125BTS 56

CH

3

V1-T5-44

V1-T5-70

CMB88B150BTS 56

Ring Style All-in-Ones (includes distribution section)
125

None

OH/UG

2

4

2/4

150

None

OH/UG

22

4

8

200

None

OH/UG

10

4

4/8

CSR2200

BR

3

V1-T5-44

V1-T5-70

MB48B200BTS 67

5

200

None

OH/UG

22

4

8

CSH2200

CH

3

V1-T5-44

V1-T5-70

CMB88B200BTS 567

200

None

UG

22

4

32/42

CSH2200

CH

7

V1-T5-43

V1-T5-69

CMB3242B200BS 56

5

200

None

OH/UG

22

—

42/42

—

CH

—

—

—

CMB4242B200BTS 5

5
5

5

None—refer
to Distribution
CSH2150

Ringless All-in-Ones (includes distribution section)
125

None

OH/UG

22

4

4/8

CSR2125

BR

21

—

V1-T5-73

MBT48B125BTS

150

None

OH/UG

22

4

4/8

CSR2150

BR

21

V1-T5-46

V1-T5-73

MBT48B150BTS

150

Horn

OH/UG

10

5

8/16

BW2150

BR

11

—

—

MB816B150STD 8

5

150

Horn

OH/UG

10

5

20/40

BW2150

BR

11

V1-T5-47

V1-T5-74

MB2040B150SD 8

200

None

OH/UG

10

4

8/16

CSR2200

BR

10

V1-T5-46

V1-T5-74

MB816B200BTS 67

5

200

None

OH/UG

10

4

8/16

CSR2200

BR

10

V1-T5-46

V1-T5-74

MB816B200BTSCU 567

200

Horn

OH/UG

10

5

8/16

BW2200

BR

11

—

—

MB816B200STD 8

5

200

None

OH/UG

2

4

8/16

Provision 4

BR

10

V1-T5-46

V1-T5-74

MB816P200BTS 67

None

OH/UG

2

5

200

4

8/16

Provision 4

BR

10

V1-T5-46

V1-T5-74

MB816P200BTSCU 567

200

Horn

OH/UG

2

5

8/16

Provision 4

BR

11

V1-T5-46

V1-T5-74

MB816P200STD 78

200

Horn

OH/UG

2

5

8/16

Provision 4

BR

10

V1-T5-46

V1-T5-74

MB816P200BTSD 7

200

None

OH/UG

10

4

12/12

CSH2200

CH

10

V1-T5-44

V1-T5-70

CMB1212B200BTS 567

OH/UG

2

4

6–2 Pole

Main lugs

CH

9

V1-T5-45

V1-T5-71

CMB1212L200BTS 57

OH/UG

2

4

12/12

Provision

CH

10

V1-T5-45

V1-T5-71

CMB1212P200BTS 567

4

6–2 Pole

Main lugs

BR

9

V1-T5-44

V1-T5-71

MB1212L200BTS 7
CMB2424B200BTS 56

5

5
5

200
200

None
None

4

5

200

None

OH/UG

2

5

200

None

OH/UG

22

4

24/24

CSH2200

CH

10

V1-T5-44

V1-T5-74

200

None

OH/UG

22

4

24/36

CSH2200

CH

10

V1-T5-45

V1-T5-74

CMB2436B200BTS 5

5

200

None

OH/UG

10

4

20/40

CSR2200

BR

10

V1-T5-47

V1-T5-74

MB2040B200BTS 6

200

None

OH/UG

2

4

20/40

Provision 4

BR

10

V1-T5-47

V1-T5-74

MB2040P200BTS 6

5

20/40

Provision

4

BR

11

V1-T5-47

V1-T5-74

MB2040P200SD 8

5

200

Horn

OH/UG

2

5

200

Horn

OH/UG

10

5

20/40

CSR2200

BR

10

V1-T5-47

V1-T5-74

MB2040B200SD 8

200

Lever

OH/UG

10

5

None

CSH2200

None

14

V1-T5-45

V1-T5-73

CMBXB200BTS 5

5

200

Lever

OH/UG

10

5

12/12

CSH2200

CH

14

V1-T5-45

V1-T5-73

CMBX1212B200BTS 57

200

Lever

OH/UG

10

5

32/42

CSH2200

CH

14

V1-T5-46

V1-T5-73

CMBX3242B200BTS 5

5

200

Lever

OH/UG

10

5

None

Provision

None

14

V1-T5-45

V1-T5-73

CMBXP200BTS 5

200

Lever

OH/UG

10

5

12/12

Provision

CH

14

V1-T5-45

V1-T5-73

CMBX1212P200BTS 57

5

200

Lever

OH/UG

10

5

32/42

Provision

CH

14

V1-T5-46

V1-T5-73

CMBX3242P200BTS 5

5

200

None

OH/UG

2

4

4/8

Provision

BR

21

V1-T5-46

V1-T5-73

MBT48P200BTS 7

200

None

OH/UG

22

4

4/8

CSR2200

BR

21

V1-T5-46

V1-T5-73

MBT48B200BTS 7

5
5
5
5

Notes
1 See Page V1-T5-68 for box details.
2 Per installed main breaker rating.
3 Will accept maximum four single-pole, two-pole, or two quad breakers.
4 When a provision for main is provided, order one of the main breakers listed on Page V1-T5-43. All panels are dual labeled to accept Types BW, CSR, CSH Main Breakers.
5 Copper bus.
6 One-piece cover on utility side, Florida approved.
7 Units come with feed-through lugs.
8 Xcel approved.

5
V1-T5-42

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Metering Products
Meter Breakers

5.9

Main Breaker Selection Chart

5

Maximum
Ampere
Rating

Two-Pole Breaker Catalog Numbers
10 kAIC

25 kAIC

25 kAIC

35 kAIC

100

BW2100

CSR2100

CSR2100N

CSH2100N

125

BW2125

CSR2125

CSR2125N

CSH2125N

150

BW2150

CSR2150

CSR2150N

CSH2150N

200

BW2200

CSR2200

CSR2200N

CSH2200N

Load Side Lug Kit for BW and CSR Breakers 1

MCBK225

5
5
5
5
5

Wiring Diagrams
Catalog Number—CMB3242B200BS 47a.

Bonded
Neutral

1
2
3
4
5
6
7
8
9
10
11
12
13

23
24
25
26
27
28
29
30
31
32

14

34

15

35

16

36

17

37

18

38

19

39

20

40

21

41

22

42

Catalog Numbers—CMBP200BTS, CMBB150BTS 47c.

5

Install 200 Ampere Maximum
Service Disconnect Type CSR 2

5

A

5

B

5

33

5

Bonded
Neutral

5
A

B

Line
N

5

Bonded
Neutral

5
5

Wiring Diagram Key
#14-2/0 AWG
#14-2 AWG
#6-250 AWG

Service Disconnect
Type CSR

A
N

B
Line

Wiring Diagram Key
#14-2 AWG
#14-4 AWG
#6-2/0 AWG
#6-250 AWG

5
5

Catalog Number—CMB24L125BTS 47d.

5

B

A

5
5
5

12 34
A

Line
N

B

5

Bonded
Neutral

5
5
5

Wiring Diagram Key
#14-1/0 AWG
#14-6 AWG
#14-1/0 AWG
#6-250 AWG

5
5

Notes
1 When a provision for main is provided, order one of the main breakers listed in this table.
All panels are dual labeled to accept Types BW, CSR and CSR Main Breakers.
2 Factory-installed MCBK225 Kit for C/B load lugs.

5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-43

5.9
5

Meter Breakers

Catalog Numbers—CMB88B200BTS, CMB88B150BTS 48a.

Catalog Number—MB1212L200BTS 48e.

Service Disconnect
Type CSR 200 Ampere Maximum

Bonded
Neutral

5

A

5

1
2
3
4
5
6
7
8

5
5

B

A
Line
N

5
5
5
5
5

A

B

Ground Bar
1

2

3

4

5

6

7

8

9

10

11

12

Wiring
Diagram Key

Wiring Diagram Key
#14-1/0 AWG
#14-6 AWG
#6-2/0 AWG
#6-250 AWG
#4-300 AWG

#14-2/0 AWG
#6-350 kcmil
#6-300 kcmil

Catalog Number—MB48B200BTS 48c.

Catalog Number—CMB2424B200BTS 48f.
A

200A Maximum
Service Disconnect
Type BW or CSR

5
5

N

B

Bonded Neutral

5

Group Metering and Meter Breakers

A

Line
N

B
Bonded
Neutral

B

5
200 Ampere
Maximum
Service Disconnect
Type CSR

1
2
3
4
5
6
7
8

5
5

A

5

Line
N

B

L1

5

L2 Bonded
Neutral

Wiring Diagram Key
#14-1/0 AWG
#14-6 AWG
#6-2/0 AWG
#6-250 AWG

5
5
5

Catalog Number—CMB1212B200BTS 48d.

5

5th Jaw Factory Installed
on CMB1212B200BTSD and
CMB1212P200BTSD Only

5

A

B
Bonded
Neutral

5

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

Wiring
Diagram Key
#14-4 AWG
#6-350 kcmil
#6-2/0 AWG
#4-300 kcmil

Line
N

5
5

200 Ampere
Maximum
Service Disconnect
Type CSR or CSH

5
5
5

1

2

3

4

5

6

7

8

9

10

11

12

5
V1-T5-44

Wiring
Diagram Key
#14-4 AWG
#6-350 kcmil
#6-2/0 AWG
#4-300 kcmil
#6-300 kcmil
Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Group Metering and Meter Breakers
Meter Breakers

Catalog Number—CMB1212L200BTS 49a.

Catalog Numbers—MBP200SD, CMBXB200BTS,
CMBXP200BTS 49c.

5th Jaw Factory Installed
on CMB1212L200BTSD Only
B

5
5

CMBXB200BTS &
CMBXP200BTS
B included lever by
pass meter socket

A
A

5.9

N

5

Line N

Bonded
Neutral

5
5
5

1

2

3

4

5

6

7

8

9

10

11

12

5

CMBXB200BTS
factory installed
200A Max Service
Disconnect type CSR

Wiring
Diagram Key
#14-4 AWG
#6-350 kcmil
#6-2/0 AWG
#6-300 kcmil

5
5

MBP200SD
install 200A Max
Service Disconnect
Type BW or CSR

5
5

Wiring
Diagram Key
#6-2/0 AWG
#6-350 kcmil
#1-300 kcmil
#6-300 kcmil

Catalog Number—CMB2436B200BTS 49b.
A

B

Line
N

5
5

Catalog Numbers—CMB1212B150BTS, CMBX1212B200BTS,
CMB1212B200BTS, CMB1212P200BTS, CMBX1212P200BTS 49d.
5th Jaw Factory Installed
on CMB1212B200BTSD and
CMB1212P200BTSD Only

Bonded
Neutral

A

B
Bonded
Neutral

5
5
5
5

Line
N

5
5

200A Max.
Service Disconnect
Type CSR or CSH

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18

19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36

Wiring
Diagram Key
#14-4 AWG
#6-350 kcmil
#6-2/0 AWG
Maximum of 12 twin
#4-300 kcmil
Breakers as Shown

5

200 Ampere
Maximum
Service Disconnect
Type CSR or CSH
1

2

3

4

5

6

7

8

9

10

11

12

5

Wiring
Diagram Key
#14-4 AWG
#6-350 kcmil
#6-2/0 AWG
#4-300 kcmil
#6-300 kcmil

5
5
5

CMBX1212B200BTS &
CMBX1212P200BTS include
lever bypass meter socket

5
5
5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-45

5.9
5

Group Metering and Meter Breakers
Meter Breakers

Catalog Numbers—MBT48B200BTS, MBT48P200BTS,
MBT48B150BTS, MBT48P150BTS 50a.

5

A

Catalog Numbers—MBB150BTSC, MBB150BTSCR,
MBB200BTSCR and MBB200BTSC 50c.
A

B

B

Line N

5
5
5

Included in
MBB150BTSCR

5

Factory or Field
installed. 15A or
200A Max. Service
Disconnect

5
5
5
5
5
5
5

Catalog Numbers—CMBX3242P200BTS,
CMBX3242B200BTS 50b.

5

A

5

Wiring Diagram Key
#6-2/0 AWG
#6-350 kcmil
#6-250 kcmil
#1-300 kcmil

Catalog Numbers—MB816P200STD, MB816B200BTS,
MB816B200BTSCU, MB816P200BTS, MB816P200BTSCU
and MB816P200BTSD 50d.
A

B
Line
N

Bonded/
Neutral

5
5

CMBX3242P200BTS
200 A Max.
Service Disconnect
Type CSR or CSH
(not included)

5

CMBX3242B200BTS
200 A Max.
Service Disconnect
Factory Installed
Type CSR or CSH

5
5

1

2

3

4

5

5

6

7

8

9

10

5

11
13

12
14

15
17

16
18
20

5
5

Bonded
Neutral

Includes Lever
Bypass Meter
Socket
Line N

B

5

5

Line N

Wiring
Diagram Key
#6-2/0 AWG
#6-350 kcmil
#1-300 kcmil
#6-300 kcmil

12 34 56 78

19
25
29
33
37

21
23
27
31
35
39

200A
Maximum
Service Disconnect
Type CSR

Bonded
Neutral

1
3
5
7
9
11
13
15

2
4
6
8
10
12
14
16

200A
Maximum
Service
Disconnect
Type BW or CSR

Wiring Diagram Key
#14-4 AWG
#6-350 kcmil
#6-2/0 AWG
#6-300 kcmil
#6-300 kcmil

Maximum of
10 Twin Breakers
as shown

22
24 26
28
30
32
34
36
38
40
41
42

Wiring
Diagram Key
#14-4 AWG
#6-350 kcmil
#6-2/0 AWG
#6-300 kcmil

5
5
5
5
V1-T5-46

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Group Metering and Meter Breakers
Meter Breakers

5.9

Catalog Numbers—MBB150BTS, MBP200SD, MBB200BTS,
MBP200BTS, MBP200BTSD, CMBXB200BTS and
CMBXP200BTS 51a.
A

5
5

B

5

Line
N

5
5

Bonded
Neutral

5

200A Maximum
Service Disconnect
Type BW or CSR 1

5
5
5

Wiring Diagram Key
#6-2/0 AWG
#6-350 kcmil
#1-300 kcmil
#6-300 kcmil

5
5
5

Catalog Numbers—MB2040P200SD, MB2040B200BTS,
MB2040P200BTS, MB2040B150SD and MB2040B200SD 51b.
A

5

B

5

Line
N

5

Bonded
Neutral

5

200A
Maximum
Service
Disconnect
Type BW or CSR
1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39

2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40

5
5
5
5

Wiring
Diagram Key
#14-4 AWG
#6-350 kcmil
#6-2/0 AWG

5
5
5
5
5
5
5
5
5
5
Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-47

5.9
5

Metering Products
Meter Breakers

Contents

Residential Meter Breakers

Description

5

Residential Meter Breakers . . . . . . . . . . . . . . . . .
Non-EUSERC Combination Service Entrance
Devices 100–200A Styles. . . . . . . . . . . . . . . . . .
Meets EUSERC Requirements Service Entrance
Devices 100–225A
West Coast All-In-One Design . . . . . . . . . . . . . . .
Mechanical Interlock Cover . . . . . . . . . . . . . . . . . .
House Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Commercial Safety Sockets . . . . . . . . . . . . . . . . .
CH Style Renovation Solutions . . . . . . . . . . . . . . .
Aluminum Meter Breakers . . . . . . . . . . . . . . . . . .

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

Meets EUSERC Requirements Service Entrance Devices 100–225A

Meets EUSERC Requirements Service Entrance Devices
100–225A
Product Description
Eaton is proud to introduce
a new line of West Coast/
EUSERC Meter Breaker units.
The new EUSERC devices
complement the existing
standard meter breaker
devices. Customers who are
interested in the complete
meter breaker line of products
can refer to Technical Data
TD.31F.01.T.E.

Features, Benefits
and Functions
●

●

●

●
●

Application Description
Eaton’s line of EUSERC
required devices adhere
to the agreed upon standards.
EUSERC utilities are
predominately located in the
western United States, but
some eastern and
midwestern utilities are
also members. These units
can also be used in many
Non-EUSERC areas.

●

●

●

●

5

Single-phase, three-wire,
120/240V, 10 kAIC
Larger 250 kcmil lugs and
additional knockouts for
ease of installation
Box type main lugs
are included
Factory-installed neutrals
Hub provisions on top
endwall. If hubs are
required, order “DS”
type hubs
Ring type sockets are
provided with a sealing ring
Padlockable device covers
provide an additional
measure of security and
help prevent tampering
Most units have center
keyhole for easy oneperson installation
NEMA 3R rainproof
construction

5
5
5
5
5
5
V1-T5-48

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Page
V1-T5-37
V1-T5-39

V1-T5-59
V1-T5-65
V1-T5-75
V1-T5-83
V1-T5-86
V1-T5-87

Metering Products
Meter Breakers

5.9

Catalog Number Selection

5
MBE 20 40 B 200 B S

Meter Breaker Type
MB
= 1-inch (25.4 mm) BR Type
MBE = 1-inch (25.4 mm) BR Type—EUSERC
CMB = 0.75-inch (19.1 mm) CH Type
CMBE = 0.75-inch (19.1 mm) CH Type—EUSERC
MBED = 7-inch (177.8 mm) deep
MBER = 1-inch (25.4 mm) BR Type—EUSERC ranch
CMBER = 0.75-inch (19.1 mm) CH Type—EUSERC ranch
MBEB = 1-inch (25.4 mm) BR Type back-to-back
MBX = Xcel approved lever bypass meter breaker

Spacing
Number of spaces
Poles
Maximum number of poles
Main
B = Main breaker included
P = Provision for main
L = Main lug
Amperes
Amperage of unit

5
D
CU
C
CR

5

Accessories/Modifications
= 5th jaw and horn bypass
= Copper
= Single cover compact design
= Two cover compact design

Mounting
S = Surface
F = Flush/stucco
Breaker Feed
BT = Bottom and top
B = Bottom only
T = Top only

5
5

Last Digits
G = Suffix = GA PWE spec
R 1 = Suffix = ECCN renovation
PV = Suffix = PV rated units
6 = 2 x 6 construction
A = Aluminum enclosure

5
5
5
5

Note
1 Not available in CR.

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-49

5.9
5
5
5
5
5
5
5

Metering Products
Meter Breakers

Product Selection
Note: See knockout drawings on Pages V1-T5-68 through V1-T5-74 for hub information.

Combination Service Entrance Devices—EUSERC
Ampere
Rating

By-pass

Service

kAIC

Jaws

Distribution

Dimensions
and Enclosure
Shape 1

Page Numbers

Main

Branch
Breaker
Type

Wiring

Knockout 1

Catalog
Number—Surface

Catalog
Number—Flush

Ring Style Meter Mains (no distribution section included)
125

None

OH/UG

2

4

2/4

MLO

BR

2

V1-T5-55 V1-T5-70

MBE24L125BTS

MBE24L125BTF

125

None

OH/UG

2

4

2/4

MLO

CH

2

V1-T5-53 V1-T5-70

CMBE24L125BTS 3

—

150

None

OH/UG

22

4

None

CSH2150N

None

3

V1-T5-52 V1-T5-70

CMBEB150BTS 3

—

200

None

OH/UG

10

4

None

CSR2200

None

3

V1-T5-56 V1-T5-70

MBEB200BTS

MBEB200BTF
—

200

None

OH/UG

22

4

None

CSH2200N

None

3

V1-T5-52 V1-T5-70

CMBEB200BTS 3

5

200

None

OH/UG

2

4

2/4

MLO

BR

3

V1-T5-56 V1-T5-70

MBE24L200BTS

MBE24L200BTF

200

None

OH/UG

2

4

2/4

MLO

CH

3

V1-T5-53 V1-T5-70

CMBE24L200BTS 3

—

5

Ring Style All-in-Ones (includes distribution section)
100

None

OH/UG

10

4

12/24

BR2100

BR

2

V1-T5-53 V1-T5-70

MBE1224B100BTS

MBE1224B100BTF

5

100

None

UG

10

4

14/28

BR2100

BR

4

V1-T5-55 V1-T5-69

MBE1428B100BS

MBE1428B100BF

5

100

None

OH

10

4

12/24

BR2100

BR

9

V1-T5-58 V1-T5-71

MBE1224B100TS

—

125

None

OH/UG

10

4

12/24

BR2125

BR

2

V1-T5-53 V1-T5-70

MBE1224B125BTS

MBE1224B125BTF

5

125

None

OH

10

4

12/24

BR2125

BR

9

V1-T5-58 V1-T5-71

MBE1224B125TS

—

125

None

UG

10

4

18/36

BR2125

BR

5

V1-T5-54 V1-T5-69

—

MBE1836B125BF

150

None

OH/UG

10

4

4/8

CSR2150

BR

19

—

—

MBER48B150BTS 48

—

150

None

OH/UG

22

4

8/8

CSH2150N

CH

19

—

—

CMBER88B150BTS 348

—

150

None

OH/UG

22

4

8

CSH2150N

CH

3

V1-T5-53 V1-T5-70

CMBE88B150BTS 34

CMBE88B150BTF 34

150

None

UG

22

4

32/42

CSH2150N

CH

7

V1-T5-52 V1-T5-69

CMBE3242B150BS 3

—

150

None

UG

10

4

20/40

CSR2150

BR

6

V1-T5-54 V1-T5-69

—

MBE2040B150BF 5

5
5
5
5
5
5
5

Notes
1 See Page V1-T5-68 for box details.
2 Interrupting rating is dependent on the main breaker that is installed.
3 Unit has copper bus.
4 Units come with feed-through lugs.
5 Please use RH-Type hubs on top end wall for overhead feed.
6 Includes factory-mounted 2.50-inch hub on bottom endwall. UG feed only.
7 Semi flush flange, not full stucco flange.
8 Units include a two-pole provision for secondary main 70A max. Type BR, BRH, BRHH.

5
5
5
5
5
5
5
5
5
5
5
V1-T5-50

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

5.9

Metering Products
Meter Breakers

Note: See knockout drawings on Pages V1-T5-68 through V1-T5-74 for hub information.

5

Combination Service Entrance Devices—EUSERC, continued

5

Ampere ByRating pass

Service

kAIC

Jaws

Distribution Main

Dimensions
and
Enclosure
Shape 1

Page Numbers

Branch
Breaker
Type

Wiring

Knockout 1

Catalog
Number—Surface

Catalog
Number—Flush

5
5

Ring Style All-in-Ones (includes distribution section), continued
150

None

OH/UG

22

4

20/40

CSR2150

BR

—

V1-T5-55

—

MBE2040B150BTS 6

—

150

None

OH/UG

10

4

4/8

CSR2150

BR

3

V1-T5-56

V1-T5-70

MBE48B150BTS

—

200

None

OH/UG

10

4

4/8

CSR2200

BR

3

V1-T5-56

V1-T5-70

MBE48B200BTS 4

MBE48B200BTF 4

200

None

OH/UG

22

4

8

CSH2200N

CH

3

V1-T5-53

V1-T5-70

CMBE88B200BTS 34

CMBE88B200BTF 34

200

None

OH/UG

10

4

8

CSR2200

BR

3

V1-T5-56

V1-T5-70

MBE88B200BTS

—

200

None

OH/UG

10

4

4/8

CSR2200

BR

19

V1-T5-58

V1-T5-73

MBER48B200BTS 48

—

200

None

OH/UG

10

4

4/8

CSR2200

BR

19

V1-T5-58

V1-T5-73

MBER48B200BTS 48

—

4

8/16

Provision

BR

10

V1-T5-57

V1-T5-71

MBE816P200TSCU 36

—

4

8/16

Provision

BR

10

V1-T5-57

V1-T5-71

MBE816P200TS 46

—
MBE1212L200BTF

200

None

OH/UG

2

200

None

OH

2

4

6–2 Pole

Main Lug

CH

5

V1-T5-52

V1-T5-69

CMBE1212L200BS 3

4

6–2 Pole

Main Lug

BR

9

V1-T5-57

V1-T5-69

MBE1212L200BTS

—

5
5
5
5
5

200

None

UG

2

200

None

OH/UG

2

200

None

OH

10

4

20/40

CSR2200

BR

10

V1-T5-57

V1-T5-71

MBE2040B200TS 6

MBE2040B200TF 5

200

None

UG

10

4

20/40

CSR2200

BR

6

V1-T5-54

V1-T5-69

MBE2040B200BS 6

MBE2040B200BF 5

200

None

OH/UG

22

4

20/40

CSR2200

BR

—

V1-T5-55

—

MBE2040BH200BTS 6

—
—
MBE3042B200BF

200

None

OH/UG

22

4

20/40

CSR2200

BR

—

V1-T5-55

—

MBE2040BH200BTF 6

200

None

UG

22

4

30/42

CSR2200

BR

7

V1-T5-54

—

—

CMBE3242B200BF

200

None

UG

22

4

32/42

CSH2200N

CH

7

V1-T5-52

V1-T5-69

200

None

UG

22

4

40

CSR2200

BR

12

V1-T5-58

—

MBE4040B200BSH 6

—

200

None

OH/UG

22

4

40

CSR2200

BR

12

V1-T5-58

—

MBE4040B200BTS

MBE4040B200BTF 7

200

None

OH/UG

22

4

42

CSH2200N

CH

12

V1-T5-57

—

CMBE4242B200BTS 3

—

200

None

OH/UG

10

4

20/40

CSR2200

BR

18

V1-T5-55

V1-T5-73

MBE2040B200BTS 6

MBE2040B200BTF 6

225

None

OH/UG

10

4

20/40

CSR2225

BR

18

V1-T5-58

V1-T5-73

MBE2040B225BTS 6

MBE2040B225BTF 6

225

None

UG

22

4

30/42

CSR2225

BR

7

V1-T5-55

—

—

MBE3042B225BF

V1-T5-69

CMBE3242B225BS 3

None

UG

22

4

32/42

CSH2225N

CH

7

V1-T5-52

CMBE3242B225BF

5
5
5

CMBE3242B200BS 3

225

5

3

3

Notes
1 See Page V1-T5-68 for box details.
2 Interrupting rating is dependent on the main breaker that is installed.
3 Unit has copper bus.
4 Units come with feed-through lugs.
5 When a provision for main is provided, order one of the main breakers listed on Page V1-T5-68. All panels are dual labeled to accept Types BW or CSR Main Breakers.
6 Please use RH-Type hubs on top end wall for overhead feed.
7 Includes factory-mounted 2.50-inch hub on bottom endwall. UG feed only.
8 Semi-flush flange, not full stucco flange.
9 Units include a two-pole provision for secondary main 70A max. Type BR, BRH, BRHH.

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-51

5.9
5

Meter Breakers

Wiring Diagrams
Catalog Numbers—CMBE3242B150BS, CMBE3242B200BS,
CMBE3242B200BF, CMBE3242B225BS and
CMBE3242B225BF 56a.
1
2
3
4
5
6
7
8
9
10
11
12
13

23
24
25
26
27
28
29
30
31
32

14

34

15

35

16

36

17

37

18

38

5

19

39

20

40

21

41

5

22

42

5
5
5

Bonded
Neutral

5

33

Bonded
Neutral

N

5
5

A

5

Line

2
4
6
8
10
12
14
16
18
20
21
22

Bonded Neutral

1
3
5
7
9
11
13
15
17
19

5
5

Install 200 Ampere Maximum
Service Disconnect Type CSR 2

A

A

5
5

Catalog Numbers—CMBEB150BTS and CMBEB200BTS 56d.

B

Service Disconnect

5
5

Wiring
Diagram Key
#14-4 AWG
#6-1/0 AWG
#6-250 AWG

Wiring Diagram Key
#14-2 AWG
#14-4 AWG
#6-2/0 AWG
#6-250 AWG

Catalog Numbers—CMBE2222P125BF and CMBE2222P125BS

Bonded Neutral

5

B

N

5
5

Line

Service Disconnect
Type CSR

5

5

B

A

5

5

2
4
6
8
10
12

1
3
5
7
9
11

Bonded Neutral

5

Catalog Number—CMBE1212L200BS 56c.
Bonded Neutral

5

Group Metering and Meter Breakers

B

A
N

Line

Wiring
Diagram Key
#14-4 AWG
#6-2/0 AWG
#14-2/0 AWG
#6-250 AWG

Line
N

B

Bonded
Neutral

Wiring Diagram Key
#14-2/0 AWG
#14-2 AWG
#6-250 AWG
Note
1 Factory-installed MCBK225 kit for C/B load lugs.

5
5
5
5
5
V1-T5-52

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Group Metering and Meter Breakers
Meter Breakers

Catalog Number—CMBE24L125BTS 57a.

5.9

Catalog Numbers—CMBE88B200BTS, CMBE88B200BTF,
CMBE88B150BTS and CMBE88B150BTF 57c.

5

Service Disconnect
Type CSR 200 Ampere Maximum

5

B

A

A

5

B

5

12 34
Line
N

B

Bonded
Neutral

1
2
3
4
5
6
7
8

B

A
Line
N
Wiring Diagram Key
#14-1/0 AWG
#14-6 AWG
#14-1/0 AWG
#6-250 AWG

5

Bonded Neutral

A

5
5
5

Wiring Diagram Key
#14-1/0 AWG
#14-6 AWG
#6-2/0 AWG
#6-250 AWG
#4-300 AWG

Catalog Number—CMBE24L200BTS 57b.

5
5
5

Catalog Numbers—MBE1224B100BTS, MBE1224B100BTF,
MBE1224B125BTS and MBE1224B125BTF 57d.

5

B

A

1
2
3
4

5

Main

12 34
A

Line
N

B

Bonded
Neutral
A

Bonded
Neutral
Wiring Diagram Key
#14-6 AWG
#14-1/0 AWG
#6-250 AWG

B

5

5

5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24

5
5
5
5

Wiring
Diagram Key
#14-6 AWG
#14-1/0 AWG
#14-2/0 AWG
#6-250 AWG

5
5
5
5
5
5
5
5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-53

5.9

5
5

Bonded Neutral

5

Catalog Numbers—MBE1212L200BF and
MBE1212L200BS
1
3
5
7
9
11

5
A
N

5

Catalog Number—MBE1836B125BF 58b.

Bonded Neutral

5
5

Line

N

Wiring
Diagram Key
#14-6 AWG
#6-1/0 AWG
#6-250 AWG

Catalog Number—MBE3042B200BF 58d.
1

2

3
5

4
6

7

8

9
11

10
12

13

14
16
18
20
22
24
26
28
30
32
34
36
38
40
42

15
17
19
21
23
25
27
29
31
33
35
37
39
41

Service Disconnect
Service
Disconnect
Type BW
or CSR

5
5
5
5

Bonded Neutral

2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
33
34
35
36

1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31

Bonded Neutral

5

B
Line

Wiring
Diagram Key
#14-4 AWG
#6-2/0 AWG
#6-250 AWG

Bonded Neutral

5

5

B

A

5

5

2
4
6
8
10
12

Service
Disconnect
Type BW
or CSR

5

5

Bonded Neutral

5

2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40

1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39

Bonded Neutral

5

Meter Breakers

Catalog Numbers—MBE2040B150BF, MBE2040B200BS
and MBE2040B200BF 58a.

Bonded Neutral

5

Group Metering and Meter Breakers

A
N

B
Line

Wiring
Diagram Key
#14-4 AWG
#6-2/0 AWG
#14-2/0 AWG
#6-250 AWG

N

A

LINE

B

Wiring
Diagram Key
#14-4 AWG
#6-2/0 AWG
#6-250 AWG

5
5
5
5
5
5
5
5
5
V1-T5-54

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Group Metering and Meter Breakers
Meter Breakers

Catalog Numbers—MBE1428B100BS and MBE1428B100BF 59a.

Bonded Neutral

Bonded Neutral

Service Disconnect

A

B
Line

N

Catalog Number—MBE3042B225BF 59c.
1

2

3
5

4
6

7

8

9
11
13

10
12

5
5
5
5
5

Service
Disconnect
Type BW
or CSR

Wiring
Diagram Key
#14-4 AWG
#6-2/0 AWG
#14-2/0 AWG
#6-250 AWG

N A

Catalog Numbers—MBE2040B200BTS, MBE2040B150BTS,
MBE2040BH200BTS and MBE2040BH200BTF 59b.

LINE

B

5

Wiring
Diagram Key
#14-4 AWG
#6-2/0 AWG
#6-250 AWG

5
5

Catalog Numbers—MBE24L125BTS and MBE24L125BTF 59d.
A

B

200A Max.
Service
Disconnect

B

A

5

14
16
18
20
22
24
26
28
30
32
34
36
38
40
42

15
17
19
21
23
25
27
29
31
33
35
37
39
41

5

Bonded Neutral

Bonded Neutral

2
4
6
8
10
12
14
16
18
20
22
24
25
26
27
28

1
3
5
7
9
11
13
15
17
19
21
23

5.9

5
5
5
5
5

1 2 34 56

B

A
N

Bonded
Neutral
Wiring
Diagram Key
#14-6 AWG
#14-1/0 AWG
#6-250 AWG

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40

A

Line
N

B

Bonded
Neutral

5
5
5
5

Wiring Diagram Key
#14-1/0 AWG
#14-6 AWG
#14-2/0 AWG
#6-250 AWG

5
5
5
5
5
5
5
5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-55

5.9
5

Group Metering and Meter Breakers
Meter Breakers

Catalog Numbers—MBE48B150BTS, MBE48B200BTS,
MBE48B200BTF 60a.

5
5
5

200A Maximum
Service Disconnect
Type BW or CSR
A

A

B

B
1 2 34 56

5

1
2
3
4
5
6
7
8

5
5

Catalog Numbers—MBE24L200BTS and MBE24L200BTF 60c.

A

Line
N

B

L1

A

Line
N

B

Bonded
Neutral

L2 Bonded
Neutral

5
5
5
5

Catalog Numbers—MBEB200BTS and MBEB200BTF 60b.

Catalog Number—MBE88B200BTS 60d.
200A Maximum
Service Disconnect
Type BW or CSR

200A Maximum
Service Disconnect
Type BW or CSR

5
5

Wiring Diagram Key
#14-1/0 AWG
#14-6 AWG
#14-2/0 AWG
#6-250 AWG

Wiring Diagram Key
#14-1/0 AWG
#14-6 AWG
#6-2/0 AWG
#6-250 AWG

A

A

B

B

5
5
5
5

MCBK225 Kit for
C/B Load Lugs
A

Line
N

B

Bonded
Neutral

5
5

Wiring Diagram Key
#14-2/0 AWG
#6-2/0 AWG
#6-250 AWG

5

A

Line
N

B

1
2
3
4
5
6
7
8

Wiring Diagram Key
#14-1/0 AWG
#14-6 AWG
#6-2/0 AWG
#6-250 AWG

5
5
5
5
5
5
5
5
5
V1-T5-56

Bonded Neutral

5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Group Metering and Meter Breakers
Meter Breakers

Catalog Numbers—MBE816P200TS and MBE816P200TSCU 61a.
A

5.9

Catalog Number—MBE1212L200BTS 61d.

B

A

5

B

5

Line
N

5

Bonded
Neutral

1
3
5
7
9
11
13
15

2
4
6
8
10
12
14
16

N

200A
Maximum
Service
Disconnect
Type BW
or CSR

1

2

3

4

5

5
5

6

7

8

9

10

11

12

Wiring Diagram Key
#14-4 AWG
#6-350 kcmil
#6-2/0 AWG
#6-300 kcmil
#6-300 kcmil

5
5

Wiring Diagram Key
#14-4 AWG
#6-350 kcmil
#6-2/0 AWG
#6-300 kcmil

Catalog Numbers— MBE2040B200TS and MBE2040B200TF 61b.
A

5

Bonded
Neutral

5
5
5

Catalog Number—CMBE1212L200TS 61e.

B
A

5

N

B

Bonded
Neutral

Line N

5
5

Bonded
Neutral

1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39

2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40

5

200A
Maximum
Service
Disconnect
Type BW
or CSR

2

3

4

5

5
5

6

7

8

9

10

11

12

5
Wiring Diagram Key
#14-4 AWG
#6-350 kcmil
#6-2/0 AWG
#6-300 kcmil

Wiring
Diagram Key
#14-4 AWG
#6-350 kcmil
#6-2/0 AWG

5

Catalog Number—CMBE4242B200BTS 61f.

5

B

1

A

B

2
3

LINE
N

B

4
5
6

A
Wiring
Diagram Key
#14-4 AWG
#6-350 kcmil
#6-2/0 AWG

5

Factory Installed
Service Disconnect
Type CSR

Bonded
Neutral

A

5
5

Catalog Number—MBE1212L200BTS 61c.
A

1

Bonded
B Neutral

Wiring
N
Diagram Key
#14-6 AWG
#14-1/0 AWG
#6 AWG-250 kcmil

1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
41

5

2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

5
5
5
5
5
5
V1-T5-57

5.9
5

Group Metering and Meter Breakers
Meter Breakers

Catalog Numbers—CMBER88B200BTS and
CMBER88B200BTF 62a.

5

Catalog Numbers—MBE2040B225BTS, MBE2040B225BTF 62d.
225A Max.
Service
Disconnect

Service
Disconnect Type CSR
or CSH Max 200A

5

A

B

A

B

A

B

5
1
2
3
4
5
6
7
8

5
5

A

5

Line
N

B

Secondary
Service
Disconnect
70A Max
Bonded
Neutral

Wire Range

5

#14-1/0

#5-2/0 AWG

#14-6 AWG

#5-250 AWG
#4-300 AWG

5

N
Bonded
Neutral
Wiring
Diagram Key
#14-6 AWG
#14-1/0 AWG
#6-250 AWG

5
5
5

Catalog Numbers—MBE4040B200BTS and
MBE4040B200BSH 62b.

5

A

5

A

B

5
5

Bonded
B Neutral

A

5

Line
N

1
3
5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39

5

5

N
Wiring
Diagram Key
#14-6 AWG
#14-1/0 AWG
#6 AWG-250 kcmil

2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40

5
5

B

Factory Installed
Service Disconnect
Type BW

5

5

Catalog Numbers—MBE1224B125TS and MBE1224B100TS 62e.

Bonded
Neutral
125A
Maximum
Service Disconnect
Type BR, or BRH
1
3
5
7
9
11
13
15
17
19
21
23

2
4
6
8
10
12
14
16
18
20
22
24

Equipment
Ground

Wiring
Diagram Key
#14-4 AWG
#14-1/0 AWG
#6-350 kcmil

Catalog Numbers—MBER48B200BTS and MER48B200BTF 62c.
Service
Disconnect Type CSR
or CSH Max 200A

5

A

B

5
5
5
5

A

Line
N

1
2
3
4
5
6
7
8

B

Secondary
Service
Disconnect
70A Max
Bonded
Neutral

Wire Range

5

#14-1/0
#14-6 AWG

5
V1-T5-58

#5-2/0 AWG
#5-250 AWG
#4-300 AWG

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Metering Products
Meter Breakers

5.9

Contents

West Coast All-In-One Design

Description
Residential Meter Breakers . . . . . . . . . . . . . . . . . .
Non-EUSERC Combination Service Entrance
Devices 100–200A Styles . . . . . . . . . . . . . . . . . .
Meets EUSERC Requirements Service Entrance
Devices 100–225A . . . . . . . . . . . . . . . . . . . . . . .
West Coast All-In-One Design
Mechanical Interlock Cover . . . . . . . . . . . . . . . . . .
House Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Commercial Safety Sockets. . . . . . . . . . . . . . . . . .
CH Style Renovation Solutions . . . . . . . . . . . . . . .
Aluminum Meter Breakers . . . . . . . . . . . . . . . . . .

Page

5

V1-T5-37

5

V1-T5-39

5

V1-T5-48

5

V1-T5-65
V1-T5-75
V1-T5-83
V1-T5-86
V1-T5-87

5
5
5
5
5
5

West Coast All-In-One Design

5

Product Description

5

A metering device that
may contain a meter
socket, main breaker and
distribution section within
the same enclosure.

Features, Benefits
and Functions
●

●

●

●

●

●

5

Semi-flush mounting.
7-inch design ideal for
stucco homes
Endwall knockouts are
easily accessible for
future wiring without
damaging stucco
Knockout in back of case
for mounting car-charging
receptacle in garage
(meets future electric
car requirements)
Outboard split neutral
for easy wiring
Commercial grade
main breaker
Value-added kits available:
Hub adapter plate

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-59

5.9
5
5

Metering Products
Meter Breakers

Product Selection
MBED3042B200BF

7-Inch Deep Meter Breaker—Standard Design OH/NG

Main

Branch
Breaker
Type

Catalog Number—
Flush

FactoryInstalled
Kits

BW2100

BR

MBED1836B100BF

—

BW2125

BR

MBED1836B125BF

—

20/40

BW2200

BR

MBED2040B200BF

—

20/40

BW2200

BR

MBED2040B200BFN

—

4

30/42

BW2200

BR

MBED3042B200BF

—

10

4

20/40

BW2225

BR

MBED2040B225BF

—

UG

10

4

20/40

BW2225

BR

MBED2040B225BFN

—

UG

10

4

30/42

BW2225

BR

MBED3042B225BF

—

5

Ampere
Rating

Bypass

Service

kAIC

Jaws

Distribution

5

100

None

UG

10

4

18/36

125

None

UG

10

4

18/36

5

200

None

UG

10

4

5

200 1

None

UG

10

4

200

None

UG

10

5

225

None

UG

225 1

None

5

225

None

5

Accessories

5
5

Hub Adapter Plate

5

Description

Catalog
Number

Hub adapter plate

MBEDADPT

5

Note
1 Main Breaker Bus connected to 20/40 distribution. Main and Disconnect in same compartment.

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
V1-T5-60

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Metering Products
Meter Breakers

5.9

Wiring Diagrams
Typical Wiring Diagram for Catalog Numbers
MBED3042B200BF, MBED3042B225BF, MBED3042BH200BF

5

Typical Wiring Diagram for Catalog Numbers
MBED2040B200BFN, MBED2040B225BFN

5
5
5
5
5
5
5
5
5
5

Typical Wiring Diagram for Catalog Numbers
MBED1836B100BF, MBED1836B125BF

Typical Wiring Diagram for Catalog Numbers
MBED2040B200BF, MBED2040B225BF, MBED2040BH200BF,
MBED2040BH225BF

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-61

5.9
5

Metering Products
Meter Breakers

Typical Wiring Diagram for Catalog Numbers
MBEB2003040BB and MBEB2253040BB

5
Loadcenter
Main Lugs

5

A

5

B

Loadcenter
Neutral
N

5
5

A

B

A

B

5
5
5
5

Line N

5

200A or
225A Max.
Service
Disconnect
Type BW
or CSR

Factory
Bonded
Neutral

Wiring
Diagram Key
#14-2/0 AWG
#6-250 AWG

5
5
5
5
5

Dimensions and Knockouts
Approximate Dimensions in Inches (mm)
7-Inch Deep Meter Breaker

5

Catalog Number—
Flush

Height

Width

Depth

5

MBED1836B100BF

38.00 (965.2)

14.19 (360.4)

7.00 (177.8)

MBED1836B125BF

38.00 (965.2)

14.19 (360.4)

7.00 (177.8)

5

MBED2040B200BF

38.00 (965.2)

14.19 (360.4)

7.00 (177.8)

MBED2040B200BFN

42.50 (1079.5)

14.19 (360.4)

7.00 (177.8)

5

MBED3042B200BF

42.50 (1079.5)

14.19 (360.4)

7.00 (177.8)

5

MBED2040B225BF

38.00 (965.2)

14.19 (360.4)

7.00 (177.8)

MBED2040B225BFN

42.50 (1079.5)

14.19 (360.4)

7.00 (177.8)

MBED3042B225BF

42.50 (1079.5)

14.19 (360.4)

7.00 (177.8)

5
5
5
5
5
5
5
5
5

V1-T5-62

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Metering Products
Meter Breakers

5.9

Approximate Dimensions in Inches (mm)

5

Catalog Numbers MBED2040B200BFN, MBED20408225BFN, MBED3042B200BF, MBED3042B225BF, MBED2040B200BF,
MBED2040B225BF, MBED1836B100BF, MBED1836B125BF

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

Knockout Configurations and Dimensions for
MBED2040B200BFN, MBED20408225BFN,
MBED3042B200BF, MBED3042B225BF, MBED2040B200BF,
MBED2040B225BF,MBED1836B100BF, MBED1836B125BF

5
5
5
5
5
5
5
5
5
5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-63

5.9
5
5

Metering Products
Meter Breakers

Approximate Dimensions in Inches (mm)
Catalog Numbers MBEB2003040BB, MBEB2253040BB

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

Knockout Configurations for MBEB2003040BB,
MBEB2253040BB

5
5
5
5
5
5
5
5
5
5
5
5
V1-T5-64

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Metering Products
Meter Breakers

5.9

Contents

Mechanical Interlock Cover

Description
Residential Meter Breakers . . . . . . . . . . . . . . . . . .
Non-EUSERC Combination Service Entrance
Devices 100–200A Styles . . . . . . . . . . . . . . . . . .
Meets EUSERC Requirements Service Entrance
Devices 100–225A . . . . . . . . . . . . . . . . . . . . . . .
West Coast All-In-One Design. . . . . . . . . . . . . . . .
Mechanical Interlock Cover
House Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Commercial Safety Sockets. . . . . . . . . . . . . . . . . .
CH Style Renovation Solutions . . . . . . . . . . . . . . .
Aluminum Meter Breakers . . . . . . . . . . . . . . . . . .

Page

5

V1-T5-37

5

V1-T5-39

5

V1-T5-48
V1-T5-59
V1-T5-75
V1-T5-83
V1-T5-86
V1-T5-87

5
5
5
5
5
5

Meter Breaker with Interlock Cover

5

Mechanical Interlock Cover

5

Product Description

5

Covers mechanically interlock
two breakers. Covers
interlock main breaker with
two-pole breaker mounted in
the distribution section of the
meter breakers.

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-65

5.9
5
5

Metering Products
Meter Breakers

Product Selection
Meter Breaker with
Interlock Cover

Mechanical Interlock Cover
Mechanical Interlock
Deadfront

Meter Breaker
Catalog Number

Mechanical Interlock
Deadfront

Meter Breaker
Catalog Number

MBDF1M

CMB1212B200BTS

MBDF1AM

CMB2424M200BTS

5

CMB1212B200BTSD

MBDF10M

CMB24B200TFR

5

CMB1212P200BTSD

5

CMB1212P200BTS

MBDF2M

5

MB816B200BTS
MB816B200BTSCU

5

CMB24B200TSR
MBDF11M

CMBXP200BTS
MBDF12M

MB816P200BTS
MB816P200BTSCU

5
5
5

MBDF4M

5

MBDF5M

5

MB2040B200BTS

5

MBDF6M

5

MBDF7M

MBE3042B225BF
MBDF14M

CMBE88B150BTF
CMBE88B150BTS

MB2040P200SD

CMBE88B200BTF

MBE816P200TS

CMBE88B200BTS

MBE816P200TSCU

CMB88B150BTS

MBE2040B150BF

CMB88B200BTS
MBDF15M

MBE48B150BTF

MBE2040B200BF

MBE48B150BTS

MBE2040B200BS

MBE48B200BTF

MBE2040B200TF
MBE2040B200TS

5

MBE3042B200BF

MB2040P200BTS

MBE2040B150BS

5

CMBX3242B200BTS
CMBX3242P200BTS

MBDF13M

MB816P200STD
MBDF3M

CMBXB200BTS

MBE48B200BTS
MBDF16M

MBE88B150BTF

MBE2040P200TF

MBE88B150BTS

MBE2040P200TS

MBE88B200BTF

CMBE3242B150BF

MBE88B200BTS

5

CMBE3242B150BS
CMBE3242B200BF

MBE2040BH200BTF

5

CMBE3242B200BS

MBE2040BH200BTS

CMB3242B150BS

MBE2040B150BTF

CMB3242B200BS

MBE2040B150BTS

CMBE4242B200BSH

MBE2040B200BTF

CMBE4242B200BTF

MBE2040B200BTS

CMBE4242B200BTS

MBE2040B200BTSV

MBE4040B200BSH

MBE2040B225BTF

5

MBE4040B200BSHH

MBE2040B225BTS

5

MBE4040B200BTS

5

MBDF8M

5
5

MBDF9M

MBDF17M

MBE2040BC200BTS

MBE4040B200BTF

5
5
5
5
5
5
5
V1-T5-66

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Metering Products
Meter Breakers

Meter Breaker Parts

1

Catalog
Number

Description
5th Jaw Kits

Technical Data and Specifications

5

Wire Size Chart

5

Main

Wire Size Range Cu/Al 60ºC
or 75ºC for Line Terminals

BR250

#14–4 kcmil

Compact and standard styles (MB and CMB)

MB5JAWKIT

BR260

#4–1/0 kcmil

EUSERC style

IMM5JKOP

BR270

#4–1/0 kcmil

BR280

#4–1/0 kcmil

BR290

#4–1/0 kcmil

BR2100

#4–1/0 kcmil

BW2125

#2–300 kcmil

BW2150

#2–300 kcmil

Horn Bypass Kits
Ringless Style units only (MB and CMB)

MBHBPKIT

Hub Selection Chart
Hub Size
Dimensions in Inches (mm)

Catalog
Number

BW2200

#2–300 kcmil

1.00 (25.4)

DS100H2

CSR2125

#2–300 kcmil

1.25 (31.8)

DS125H2

CSR2150

#2–300 kcmil

1.50 (38.1)

DS150H2

CSR2200

#2–300 kcmil

2.00 (50.8)

DS200H2

CSR2125N

#1/0–250 kcmil

2.50 (63.5)

DS250H2

CSR2150N

#1/0–250 kcmil

DS300H2

CSR2200N

#1/0–250 kcmil

125A main lugs

—

200A main lugs

—

MCBK225

#2–300 kcmil

3.00 (76.2)

Top Endwall (Surface)

5.9
5
5
5
5
5
5
5
5
5
5
5

Hub Provision
Catalog Number

5
Wire Size is Determined by the Circuit Breaker Installed
in the Enclosure

DS100H2
DS125H2

Maximum

DS150H2
DS200H2

Wire/Application

Wire Size

Ampere
Rating

DS250H2

Aluminum—Standard

250 kcmil

200

DS300H2

Aluminum—Service Entrance

250 kcmil

225

Copper—Standard and Service Entrance

250 kcmil

225

DS900AP

(Adapter Plate if using DS___H1 hubs only) 2

5
5
5
5

Notes
1 For breakers under 70A used in backfed applications, add “B” to the end of the catalog string
to get the appropriate “hold-down” version.
2 Use when DS H1 Type 1, 1.25 and 1.50-inch hubs are needed.
Use DS...H2 hubs for bottom endwalls (for all units). Use RH hubs for top endwalls on semi-flush
units. Use DS...H2 hubs for top endwalls on surface devices.

5
5
5
5
5
5
5
5
5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-67

5.9
5
5

Metering Products
Meter Breakers

Dimensions and Knockouts
Approximate Dimensions in Inches (mm)
Box Styles—Five Different Styles (Shapes) of Product

5

B

A

C

D

E

5
5
5
5
5

Box Dimensions

5

Box
Number

Height

Width

Depth

Box
Style

5

1

12.50 (317.5)

14.44 (366.7)

4.00 (101.6)

A

2

23.88 (606.4)

14.44 (366.7)

5.38 (136.5)

A

5

3

28.38 (720.7)

14.44 (366.7)

5.38 (136.5)

A

5

4

34.13 (866.8)

14.44 (366.7)

5.38 (136.5)

B

5

36.13 (917.6)

14.44 (366.7)

5.38 (136.5)

B

5

6

43.38 (1101.7)

14.44 (366.7)

5.38 (136.5)

B

7

46.88 (1190.6)

14.44 (366.7)

5.38 (136.5)

B

5

8

19.75 (501.7)

7.50 (190.5)

4.00 (101.6)

C

9

25.00 (635.0)

14.44 (366.7)

5.38 (136.5)

C

5

10

32.38 (822.3)

14.44 (366.7)

5.38 (136.5)

C

5

11

36.63 (930.3)

14.44 (366.7)

5.38 (136.5)

C

12

34.38 (873.1)

22.00 (558.8)

5.38 (136.5)

D

5

13

19.75 (501.7)

14.44 (366.7)

5.38 (136.5)

E

14

39.91 (1013.7)

14.44 (366.7)

5.38 (136.5)

C

5

15

23.88 (606.6)

13.00 (330.2)

4.94 (125.5)

F

5

16

28.38 (720.9)

13.00 (330.2)

4.94 (125.5)

F

17

34.19 (868.4)

22.13 (562.1)

5.00 (127.0)

D

5

18

36.06 (915.9)

16.63 (422.4)

5.50 (139.7)

A

19

28.38 (720.9)

14.44 (366.8)

4.94 (125.5)

A

5

20

32.06 (814.3)

14.44 (366.8)

4.94 (125.5)

C

21

25.50 (647.7)

14.44 (366.8)

4.94 (125.5)

C

5
5
5
5
5
5
5
5
5
V1-T5-68

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

F

Metering Products
Meter Breakers

5.9

Approximate Dimensions in Inches (mm)
Knockouts for Stucco and Surface Units Catalog Numbers—
CMBE3242B200BF, CMBE3242B225BF, MBE2040B200BF,
MBE2040B150BF, MBE1428B100BF, MBE1212L200BTF,
MBE1836B125BF and MBE1212L200BTS 62a.
Keyhole Knockouts on Sides for Stucco Units Only.

3-1/2
88.9
(88.9)

Hub Provision
Catalog Number

4-15/16
(125.4)

Quantity

DS100H2

1

DS125H2

1

DS150H2

1

DS200H2

1

DS250H2

1

DS300H2

1

DS900AP

Top
T
op Stucco

5

Top Endwall (Surface)

(Adapter Plate if using DS___H1 hubs only) 2

5
5
5
5

1

5
5

Top Endwall (Stucco) 3
Knockout Size
Dimensions in Inches (mm)

Quantity

1.25, 1.50, 2.00, 2.50 (31.8, 38.1, 50.8, 63.5)

1

1.00, 1.25, 1.50 (25.4, 31.8, 38.1)

1

0.50, 0.75, 1.00 (12.7, 19.1, 25.4)

1

0.50, 0.75 (12.7, 19.1)

3

0.50 (12.7)

3

5-5/16
(134.9)

5
5
5
5

Bottom

Knockouts for Stucco and Surface Units Catalog Numbers—
CMBE3242B150BS, CMBE3242B200BS, CMBE3242B225BS,
CMBE1212L200BS, MBE2040B200BS, MBE1428B100BS,
MBE1212L200BTS, CMB3242B150BS and
CMB3242B200BS 62b.

5

5

Bottom Endwall
Knockout Size
Dimensions in Inches (mm)

Quantity

0.50 (12.7)

7

0.50, 0.75 (12.7, 19.1)

4

0.50, 0.75, 1.00 (12.7, 19.1, 25.4)

1

1.00, 1.25, 1.50, 2.00 (25.4, 31.8, 38.1, 50.8)

1

1.25, 1.50, 2.00, 2.50, 3.00 (31.8, 38.1, 50.8, 63.5, 76.2)

1

5
5
5
5

Notes
1 For details regarding quantities, please contact the Technical Resource Center (TRC)
at 1-877-ETN-CARE.
2 Use when DS H1 Type 1, 1.25 and 1.50-inch hubs are needed.
3 RH hubs are to be used for Top Endwall (Stucco) endwalls.

Top Surface

5
5
5
5
5
5

4-15/16
(125.4)

5
5

Bottom

5
5
5
5
5
Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-69

5.9
5
5
5

Meter Breakers

Approximate Dimensions in Inches (mm)
Knockouts for Stucco and Surface Units Catalog Numbers—
CMBE88B150BTF, CMBE88B200BTF, MBE24L125BTF,
MBE24L200BTF, MBE48B200BTF, MBEB200BTF,
MBE1224B100BTF and MBE1224B125BTF 63a.
Keyhole Knockouts on Sides for Stucco Units Only.

5
5

Metering Products

3-1/2
(88.9)

5

Top Endwall (Surface)
Hub Provision
Catalog Number
DS100H2

1

DS125H2

1

DS150H2

1

DS200H2

1

DS250H2

1
1

DS300H2
DS900AP

5
5

Top Stucco

Quantity

(Adapter Plate if using DS___H1 hubs only) 2

1

Top Endwall (Stucco) 3

5

Knockout Size
Dimensions in Inches (mm)

5

1.25, 1.50, 2.00, 2.50 (31.8, 38.1, 50.8, 63.5)

1

1.00, 1.25, 1.50 (25.4, 31.8, 38.1)

1

0.50, 0.75, 1.00 (12.7, 19.1, 25.4)

1

0.50, 0.75 (12.7, 19.1)

3

0.50 (12.7)

3

5

4-15/16
(125.4)

5

Bottom

5
5
5
5
5

Knockouts for Stucco and Surface Units Catalog Numbers—
CMBB150BTS, CMBB200BTS, CMBP200BTS,
CMBE24L125BTS, CMB24L125BTS, CMBE24L200BTS,
CMBEB200BTS, CMBEB150BTS, CMBE88B150BTS,
CMBP200BTS, CMBE88B200BTS, MBE24L125BTS,
MBE24L200BTS, MBE48B150BTS, MBE48B200BTS,
MBE88B200BTS, MBEB200BTS, MBE1224B100BTS,
MBE1224B125BTS, CMB88B150BTS, CMB88B200BTS
and MB48B200BTS 63b.

5
5
5

Bottom Endwall
Knockout Size
Dimensions in Inches (mm)

7

0.50, 0.75 (12.7, 19.1)

4

0.50, 0.75, 1.00 (12.7, 19.1, 25.4)

1

1.00, 1.25, 1.50, 2.00 (25.4, 31.8, 38.1, 50.8)

1

1.25, 1.50, 2.00, 2.50, 3.00 (31.8, 38.1, 50.8, 63.5, 76.2)

1

Notes
1 For details regarding quantities, please contact the Technical Resource Center (TRC)
at 1-877-ETN-CARE.
2 Use when DS H1 Type 1, 1.25 and 1.50-inch hubs are needed.
3 RH hubs are to be used for Top Endwall (Stucco) endwalls.

5-5/16
(134.9)

5

Top Surface

5
5

4-15/16
(125.4)

5

Bottom

5
5
5
5
V1-T5-70

Quantity

0.50 (12.7)

5

5

Quantity

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Metering Products
Meter Breakers

5.9

Approximate Dimensions in Inches (mm)
Knockouts for Stucco and Surface Units Catalog Number—
MMBE2040B200TF 64a.
Keyhole Knockouts on Sides for Stucco Units Only.

Knockouts for Stucco and Surface Units Catalog Numbers—
MBE1224B100TS, MBE1224B125TS, MBE816P200TS,
MBE816P200TSCU, MBE2040B200TS, CMB1212P200BTS,
CMB1212P200BTSD, CMB1212B200BTS, MB1212L200BTS
and CMB1212L200BTS 64b.

5
5
5

3.50
(88.9)

5
5.31
(134.9)

5
5

Top Stucco

5

Top Surface

5

4.94
(125.4)

5

4.94
(125.4)

5

Bottom

5

Bottom

Top Endwall (Surface)
Hub Provision
Catalog Number

Quantity

DS100H2

1

DS125H2

1

DS150H2

1

DS200H2

1

DS250H2

1

DS300H2

1

DS900AP

5

(Adapter Plate) 2

1

Knockout Size
Dimensions in Inches (mm)

Quantity

0.50 (12.7)

7

0.50, 0.75 (12.7, 19.1)

4

0.50, 0.75, 1.00 (12.7, 19.1, 25.4)

1

1.00, 1.25, 1.50, 2.00 (25.4, 31.8, 38.1, 50.8)

1

1.25, 1.50, 2.00, 2.50, 3.00 (31.8, 38.1, 50.8, 63.5, 76.2)

1

1

1.00, 1.25, 1.50 (25.4, 31.8, 38.1)

1

0.50, 0.75, 1.00 (12.7, 19.1, 25.4)

1

0.50, 0.75 (12.7, 19.1)

3

0.50 (12.7)

3

5
5

Quantity

1.25, 1.50, 2.00, 2.50 (31.8, 38.1, 50.8, 63.5)

5
5

Notes
1 For details regarding quantities, please contact the Technical Resource Center (TRC)
at 1-877-ETN-CARE.
2 Use when DS H1 Type 1, 1.25 and 1.50-inch hubs are needed.
3 RH hubs are to be used for Top Endwall (Stucco) endwalls.

Top Endwall (Stucco) 3
Knockout Size
Dimensions in Inches (mm)

5

Bottom Endwall

5
5
5
5
5
5
5
5
5
5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-71

5.9
5
5
5

Metering Products
Meter Breakers

Approximate Dimensions in Inches (mm)
Knockouts for Stucco and Surface Units
3.44
(87.3)

5
5

Top Flush
MBE4040B200BTF

5
5
5

5.31
(134.9)

5.31
(134.9)

5

Top Surface

5

Top Surface
2-1/2-inch Hub

5
5

4.94
(125.4)

4.94
(125.4)

5
5
5
5
5

Bottom

Bottom

CMBE4242B200BTS
MBE4040B200BTS

MBE4040B200BSH

Bottom Endwall

Top Endwall (Surface)
Hub Provision
Catalog Number

Quantity

Knockout Size
Dimensions in Inches (mm)

Quantity

DS100H2

1

0.50, 0.75 (12.7, 19.1)

6

5

DS125H2

1

0.50, 0.75, 1, 1.25 (12.7, 19.1, 25.4, 31.8)

2

1

5

DS150H2

1.00, 1.25, 1.50, 2.00, 2.50 (25.4, 31.8, 38.1, 50.8, 63.5)

1

DS200H2

1

1.00, 1.25, 1.50, 2.00, 2.50, 3.00 (25.4, 31.8, 38.1, 50.8, 63.5, 76.2)

1

5

DS250H2

1

DS300H2

1

5

DS900AP

(Adapter Plate) 2

1

5

Top Endwall (Stucco) 3

5

Knockout Size
Dimensions in Inches (mm)

Quantity

5

1.25, 1.50, 2.00, 2.50 (31.8, 38.1, 50.8, 63.5)

2

0.50, 0.75 (12.7, 19.1)

3

5

Notes
1 For details regarding quantities, please contact the Technical Resource Center (TRC)
at 1-877-ETN-CARE.
2 Use when DS H1 Type 1, 1.25 and 1.50-inch hubs are needed.
3 RH hubs are to be used for Top Endwall (Stucco) endwalls.

5
5
5
5
5
V1-T5-72

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Metering Products
Meter Breakers

5.9

Approximate Dimensions in Inches (mm)
Knockout Configurations and Dimensions for Catalog
Numbers MBER48B200BTS and CMBER88B200BTS 66a.

Semi-Flush Stucco Unit Knockout Configurations and
Dimensions for MBE2040B200BTS, MBE2040B225BTS,
MBE2040B200BTF and MBE2040B225BTF 66d.

5
5
5
5

5-5/16"

5
Top Surface

5
5
5

4-15/16"

5
5

Bottom End
Mounting Surface

Knockout Configurations and Dimensions for
Catalog Numbers CMBXP200BTS, CMBXB200BTS,
CMBX1212P200BTS and CMBX3242P200BTS,
CMBX3242B200BTS, CMBX1212B200BTS 66b.

5
Knockout Configurations and Dimensions for Catalog
Numbers MBT48B125BTS, MBT48B150BTS, MBT48B200BTS
and MBT48P200BTS 66e.

5
5
5
5

5-5/16"

5
5

Top Surface

5
5
4-15/16"

5
5

Bottom

5
5

Surface Unit Knockout Configurations and Dimensions for
MBE2040B200BTS, MBE2040B225BTS, MBE2040B200BTF
and MBE2040B225BTF 66c.

5
5
5
5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-73

5.9
5
5
5
5

Metering Products
Meter Breakers

Approximate Dimensions in Inches (mm)
Knockouts for Non-EUSERC Units Catalog Numbers—
MBB150BTS, MBB200BTS, MBP200BTS, MB816P200BTS,
MB816P200BTSCU, MB816P200BTSD, MB816B200BTS,
MB816B200BTSCU, MB2040P200BTS, MB2040B200BTS,
MBP200BTSD, MBP200SD, MB816P200STD,
MB2040B150SD, MB2040B200SD and MB2040P200SD 67a.

Knockouts for Non-EUSERC Units Catalog Numbers—
CMB2424B200BTS, MBB150BTSCR, MBB200BTSCR,
MBB150BTSC, MBB200BTSC and CMB2436B200BTS 67c.

5
5

5.31
(134.9)

5.31
(134.9)

5
5

Top Surface (Catalog Numbers with SC and SCR Suffix Only)

Top Surface

5
5
5

4.94
(125.4)

4.94
(125.4)

5

Bottom

Bottom

5

Top Endwall (Surface)

5

Hub Provision
Catalog Number

Bottom Endwall
Quantity

Knockout Size
Dimensions in Inches (mm)

Quantity

DS100H2

1

0.31 (7.9)

3

DS125H2

1

0.50 (12.7)

3

DS150H2

1

0.50, 0.75 (12.7, 19.1)

2

5

DS200H2

1

0.75, 1.00 (12.7, 25.4)

1

DS250H2

1

1.25, 1.50, 2.00, 2.50 (19.1, 38.1, 50.8, 63.5)

2

5

DS300H2

1

1.50, 2.00, 2.50, 3.00 (38.1, 50.8, 63.5, 76.2)

1

5
5

5
5

DS900AP

(Adapter Plate)

1

2

Knockouts for Non-EUSERC Units Catalog Number—
CHMMB100BTS 67b.

5
5
5

Knockouts for Non-EUSERC Units Catalog Numbers—
CHMMB150BTS and CHMMB200BTS 67d.

4.94
(125.4)
4.94
(125.4)
Bottom

5

Bottom

Bottom Endwall

5

Bottom Endwall

Knockout Size
Dimensions in Inches (mm)

Quantity

5

Knockout Size
Dimensions in Inches (mm)

Quantity

0.31 (7.9)

1

5

0.31 (7.9)

1

5

0.50 (12.7)

1

0.50, 0.75, 1.00, 1.25, 1.50, 2.00, 2.50 (12.7, 19.1, 25.4, 31.8, 38.1, 50.8, 63.5)

2

1,00, 1.25, 1.50, 2.00, 2.50 (25.4, 31.8, 38.1, 50.8, 63.5)

1

5
5

V1-T5-74

0.50 (12.7)

1

0.50, 0.75, 1.00, 1.25, 1.50, 2.00, 2.50 (12.7, 19.1, 25.4, 31.8, 38.1, 50.8, 63.5)

2

1.00, 1.25, 1.50, 2.00, 2.50, 3.00 (25.4, 31.8, 38.1, 50.8, 63.5, 76.2)

1

Notes
1 For details regarding quantities, please contact the Technical Resource Center (TRC)
at 1-877-ETN-CARE.
2 Use when DS H1 Type 1, 1.25 and 1.50-inch hubs are needed.

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Metering Products
Meter Breakers

5.9

Contents

House Panels

Description

Page

Residential Meter Breakers . . . . . . . . . . . . . . . . . .
Non-EUSERC Combination Service Entrance
Devices 100–200A Styles . . . . . . . . . . . . . . . . . .
Meets EUSERC Requirements Service Entrance
Devices 100–225A . . . . . . . . . . . . . . . . . . . . . . .
West Coast All-In-One Design. . . . . . . . . . . . . . . .
Mechanical Interlock Cover . . . . . . . . . . . . . . . . . .
House Panels
Commercial Safety Sockets. . . . . . . . . . . . . . . . . .
CH Style Renovation Solutions . . . . . . . . . . . . . . .
Aluminum Meter Breakers . . . . . . . . . . . . . . . . . .

5

V1-T5-37

5

V1-T5-39

5

V1-T5-48
V1-T5-59
V1-T5-65
V1-T5-83
V1-T5-86
V1-T5-87

5
5
5
5
5
5
5
5

House Panels
Product Description

Application Description

Eaton’s House Panels offer
a faster, easier and safer
installation.These 400A units
are ideal for larger homes in
North America that require
meter breakers. Available in
both CH and BR styles, these
service entrance devices
consist of a meter socket
and a distribution section.
In response to contractor
feedback, these panels
have been redesigned with a
focus on flexibility, simplified
wiring, and an overall ease of
installation. All units come
standard with a 22 kAIC main
breaker.The load conductors
can exit the top, bottom, side
or back for greater application
and installation flexibility.

Additionally, Eaton’s House
Panels can be used for
apartments, condominiums,
clubhouses or common
areas.

Features, Benefits
and Functions
●
●

●

●
●

●

NEMA 3R rainproof
Rated for service entrance
equipment
Lever bypass socket
available on certain
catalog numbers
Pin type door hinges
Socket to distribution
section is connected via
insulated cable for safety
Second main space can
accept 100–200A BW, CSR
or CSR breakers

Standards and Certifications
●

●

Ring style units meet
EUSERC requirements
UL listed

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-75

5.9
5
5

Metering Products
Meter Breakers

Product Selection

House Panels

400A “House Panels”

5
5

Ampere
Rating

5

Security 1

Bypass 2

Main
Breaker

Optional
Secondary
Main
Breaker
(Not
Included)

Service
Type

kAIC

Dist.

300

Ringless

Lever

CSR2150

BW/CSR

OH/UG

22

8/16

5

300

Ringless

Lever

CSR2150

BW/CSR

UG

22

None

5

400

Ring

None

CSH2200N

CSR

UG

22

400

Ring

None

CSH2200N

CSR

UG

22

5

400

Ring

Manual

CSR2200

BRH/CSR

UG

400

Ring

Manual

CSR2200

BRH/CSR

5

400

Ringless

None

DK2400

400

Ringless

None

CSR2200

5

400

Ring

None

DK2400

None

UG

5

400

Ring

None

CSR2200

BRH/CSR

UG

400

Ring

None

DK2400

None

UG

5

400

Ring

None

CSR220

BRH/CSR

UG

400

Ring

Manual

CSR2200

BRH/CSR

UG

5

400

Ring

None

CSR2200

BRH/CSR

400

Ringless

Lever

CSH2200N

CSR

Line Side
Main Lugs
and Neutral
(Lugs Not
Included)
Lug
landings for
compression

SemiFlush
Catalog
Number 3

Surface
Catalog
Number

—

HP816P400BSL

—

HPC30SHL

32/42

—

CG403242SH

12/12

—

CG1212P400BS 5

22

None

—

HP40SHA 8

UG

22

40/40

—

HP404040SHA 68

None

UG

22

24/40

—

HP402440B 7

BRH/CSR

UG

22

24/40

—

HP402440SBH 78

22

None

—

HP40

22

None

—

HP40SH 8

22

24/42

—

HP402442

22

40/40

HP404040SHF

HP404040SH 8

22

40/40

HP404040SHFA 6

—

UG

22

8/16

—

HP816P400BS 58

UG

22

12/12

—

CG1212P400BSL 5

5

400

Ringless

Lever

CSH2200N

CSR

UG

22

42/42

—

CG404242SHL

5

400

Ringless

Lever

CSR2200

BRH/CSR

UG

22

None

—

HP40SHL 8

400

Ringless

Lever

CSR2200

BRH/CSR

OH/UG

22

None

—

HPC40SHL 8

5

400

Ringless

Lever

CSR2200

BRH/CSR

UG

22

40/40

—

HP404040SHL 8

400

Ringless

Lever

CSR2200

BRH/CSR

UG

22

8/16

—

HP816P400BSL 58

5

400

Ringless

Lever

CSR2200

BRH/CSR

OH/UG

22

4/6

—

HPC4046SHLG 9

400

Ringless

Lever

CSR2200

BRH/CSR

OH/UG

22

4/6

—

HPC4046SHLX j

5

Notes
1 Confirm security type for individual EUSERC utility requirements.
2 Included in all of the following devices.
3 If unit needs to be semi-flush, order accessory item catalog number HPPR to convert all surface mounting devices to semi-flush mounting.
4 Secondary sub-main installed in panel.
5 Feed-through lugs included.
6 Includes manual bypass and additional ground lug to meet Nevada Power requirements.
7 Bolt-on meter socket.
8 For 10 kAIC, use BR or BW breakers as secondary main.
9 Georgia Power approved.
j Xcel approved.

5
5
5
5
5
5
5
5
5
5
5
5
V1-T5-76

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Metering Products
Meter Breakers

5.9

Accessories
●

●

●

●

5

Top-feed gutter kit to ease
top-fed installation
Re-engineered, adjustable
flush mount kit for a
cleaner installation
100A second main
breaker kit
New 750 kcmil box type
lug kit

5
5
5
5
5

Accessories

HP40TFKIT

Description

Catalog
Number

Top feed kit to convert surface mount house panel for overhead service

HP40TFKIT

5
5
5
5
5
5
5

HPBLK750

750 kcmil lug kit

5

HPBLK750

5
HPBPK

Manual bypass kit

5

HPBPK

5
5
HP2NDMNKIT

Flushmount kit

HPPR

100A 2nd main kit (Type BR branch)

HP2NDMNKIT

100A 2nd main kit (Type CH branch)

CH2NDMNKIT

5th jaw for lever bypass house panels

ARP00326CH

Locates 3-inch (only) incoming conduit to back of can by utilizing the 4-inch knockout useful in semi-flush applications

HP40HUBPLATE

5
5
5
5
5
5
5
5
5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-77

5.9

Metering Products
Meter Breakers

5

Wiring Diagrams

5

Type CH Style House Panels

5

Type CH Wiring—Catalog Number CG403242SH

5
5
A

N

400 AMPERES
(320 AMPERES
CONTINUOUS) 1

2

3

4

5

6

7

8

B

LINE

5

9

10

11

12

13

14

15

16
18
20
21
22
24
26
28
30
32
34
36
38
40
42

17

5

19
23
25
27
29
31
33
35
37
39
41

5
5

FACTORY/FIELD
INSTALLED
100 A MAXIMUM
SERVICE
DISCONNECT
TYPE CH

OPTIONAL
200 A MAXIMUM
SERVICE
DISCONNECT
TYPE BW
OR CSR

AMPERES
(CONTINUOUS)

EQUIPMENT
GROUNDING
TERMINALS

A

N

B

LINE

5
A

N
LINE

B

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15
17

16
18

19

20

5

21

22

23

24

25

26

5

27
29

28

31

32

33

34

35

36

37

38

39

40

41

42

5
5

5
5

30

7

8

9

10

11

12

FACTORY/FIELD
INSTALLED
200 A MAXIMUM
SERVICE
DISCONNECT
FACTORY/FIELD
INSTALLED
100 A MAXIMUM
SERVICE
DISCONNECT
TYPE CH

400 AMPERES
(320 AMPERES
CONTINUOUS)

A

N

B

LINE

1
3
5
7
9
11

100 A MAX.
SERVICE
DISCONNECT
TYPE CH

2
4
6
8
10
12
BONDED
NEUTRAL

EQUIPMENT
GROUNDING
TERMINALS

BONDED
NEUTRAL

OPTIONAL
200 A MAX.
SERVICE
DISCONNECT
TYPE CSR

OPTIONAL
200 A MAXIMUM
SERVICE
DISCONNECT
TYPE BW
OR CSR

Type CH Wiring Diagram Key
#14-6 AWG
#14-1/0 AWG
1/0 – 300 kcmil
#4 AWG – 300 kcmil

5
5
5
5
5
5
V1-T5-78

6

Type CH Wiring—Catalog Number CG1212P400BSL

FACTORY
INSTALLED
200 A
SERVICE
DISCONNECT
TYPE CSR
400 AMPERES
(320 AMPERES
CONTINUOUS)

5

2
4

5

BONDED
NEUTRAL

(OPTIONAL)

5

1
3

BONDED
NEUTRAL

Type CH Wiring—Catalog Number CG404242SHL

5

5

FACTORY/FIELD
INSTALLED
200 A MAXIMUM
SERVICE
DISCONNECT
TYPE CSR

FACTORY
INSTALLED
200 A
SERVICE
DISCONNECT

5

5

OPTIONAL
200 A MAX.
SERVICE
DISCONNECT
TYPE CSR
100 A MAX.
SERVICE
DISCONNECT
TYPE CH

(OPTIONAL)

5

5

Type CH Wiring—Catalog Number CG1212P400BS

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Metering Products
Meter Breakers

5.9

Type BR Style House Panels

5

Type BR Wiring—Catalog Number HP40

F ACTOR Y
INSTALLED
400 A
SER VICE
DISCONNECT
TYPE DK

A

N

B

5

100 A MAX.
SERVICE
DISCONNECT

1
3
5
7
9
11
13
15

LINE

N

(OPTIONAL)
200 A MAX.
SERVICE
DISCONNECT
TYPE BW OR
CSR

FACTORY
INSTALLED
200 A MAX.
SERVICE
DISCONNECT
TYPE CSR

400 AMPS
(320 AMPS
CONTINUOUS)

400 AMPERES
(320 AMPERES
CONTINUOUS)

A

5

Type BR Wiring—Catalog Number HP816P400BS

5

2
4
6
8
10 EQUIPMENT
12 GROUNDING
14 TERMINALS
16

5
5

BONDED
NEUTRAL

B

5

LINE
BONDED
NEUTRAL

5
5

Type BR Wiring—Catalog Number HP402440B

5

Type BR Wiring—Catalog Number HP402440SBH
FACTORY
INSTALLED
400 A
SERVICE
DISCONNECT
TYPE DK

400 AMPS
(320 AMPS
CONTINUOUS)

A

N

B

LINE

(OPTIONAL)

1

2

3

4

5

6

7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39

8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40

N

B

LINE

BONDED
NEUTRAL

5

100 A MAX.
SERVICE
DISCONNECT
TYPE BRH OR
BR

400 AMPS
(320 AMPS
CONTINUOUS)

A

5

FACTORY/FIELD
INSTALLED
200 A MAX.
SERVICE
DISCONNECT
TYPE CSR OR
BW

FACTORY
INSTALLED
200 A
SERVICE
DISCONNECT
TYPE CSR

1

2

3

4

5

6

7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39

8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40

5
5

BONDED
NEUTRAL

5
5
5

Type BR Wiring—Catalog Number HP404040SH

5

Type BR Wiring Diagram Key

5

#14-6 AWG
(OPTIONAL)
FACTORY/FIELD
INSTALLED
200 A MAXIMUM
SERVICE
DISCONNECT
TYPE CSR
OR BW

FACTORY
INSTALLED
200 A
SERVICE
DISCONNECT
TYPE CSR

400 AMPERES 1
(320 AMPERES
3
CONTINUOUS)
5
A

N
LINE

B

7
9

100 A MAXIMUM
SERVICE
DISCONNECT
TYPE BRH OR BR

5

#14-1/0 AWG
#6 AWG – 250 kcmil

5

#1 AWG – 300 kcmil

5

2
4
6 EQUIPMENT
8 GROUNDING
TERMINALS
10

11

12

13

14

15

16

17

18

19

20

21

22

23
25

24
26

27

28

29

30

31

32

33

34

35

36

37
39

38

BONDED
NEUTRAL

1/0 – 300 kcmil
#4 AWG – 300 kcmil

5

#6 AWG – 300 kcmil

5
5
5

40

5
5
5
5
Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-79

5.9
5

Meter Breakers

Type BR Wiring—Catalog Number HP402442

5

FACTORY
INSTALLED
BY-PASS.

400 AMPERES
(320 AMPERES
CONTINUOUS)

A

N

1

B

LINE

5
5
5
5

3

4

5
7
9
11
13
15
17
19
21
23
25
27
29
31
33
35
37
39
41

6
8
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
40
42

FACTORY
INSTALLED
200 A
SERVICE
DISCONNECT
TYPE CSR
400 AMPS
(320 AMPS
CONTINUOUS)

B

A
LINE

1

2

3
BONDED
NEUTRAL 5
7

4

9

10

11

12

N

14

5

17

16
18

19

20

21

22

5

25

26

27

28

29

30

31

32

5

33

34

35

36

37

38

39

40

23

BONDED
NEUTRAL
GROUNDING
LUG

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31
33

32
34

35
37

36
38

39

40

OPTIONAL
200 A MAX.
SERVICE
DISCONNECT
TYPE CSR

FACTORY/FIELD
INSTALLED
200 A MAX.
SERVICE
DISCONNECT
TYPE BW OR
CSR
100 A MAX.
SERVICE
DISCONNECT
TYPE BR OR
BHR

FACTORY
INSTALLED
200 A MAX.
SERVICE
DISCONNECT

400 AMPS
(320 AMPS
CONTINUOUS)

A

N

B

LINE

100 A MAX.
SERVICE
DISCONNECT

1
3
5
7
9
11
13
15

2
4
6
8
10
12
14
16

24

Type BR Wiring Diagram Key
#14-6 AWG

(OPTIONAL)
FACTORY/FIELD
INSTALLED
200A MAX.
SERVICE
DISCONNECT
TYPE CSR OR
BW
100A MAX.
SERVICE
DISCONNECT
TYPE BRH OR
BR

FACTORY
INSTALLED
200 A
SERVICE
DISCONNECT
TYPE CSR
400 AMPS
(320 AMPS
CONTINUOUS)

#6 AWG – 250 kcmil
#1 AWG – 300 kcmil
1/0 – 300 kcmil
1/3 – 300 kcmil 1
#4 AWG – 300 kcmil
#6 AWG – 300 kcmil

A

N

B

LINE
BONDED
NEUTRAL

Type BR Wiring—Catalog Number HP40SHL

5

FACTORY
INSTALLED
200 A
SERVICE
DISCONNECT
TYPE CSR

5

400 AMPS
(320 AMPS
CONTINUOUS)

5

(OPTIONAL)
FACTORY/FIELD
INSTALLED
200 A MAX.
SERVICE
DISCONNECT
TYPE BW OR
CSR
100 A MAX.
SERVICE
DISCONNECT
TYPE BR OR
BRH

BONDED
NEUTRAL
A LINE B

N

5
5
V1-T5-80

EQUIPMENT
GROUNDING
TERMINALS

BONDED
NEUTRAL

#14-1/0 AWG

5

5

LINE

1

Type BR Wiring—Catalog Number HP40SH

5

5

9

B

8

15

5

6
EQUIPMENT
8 GROUNDING
10 TERMINALS

7
N

100 A MAX.
SERVICE
DISCONNECT
TYPE BRH
OR BR

6

13

5

4

(OPTIONAL)

5

5

2

3
5

2
A

1

Type BR Wiring—Catalog Number HP816P400BSL

5

5

FACTORY/FIELD
INSTALLED
200 A MAX.
SERVICE
DISCONNECT
TYPE CSR
OR BW

Type BR Wiring—Catalog Number HP404040SHL

5
5

(OPTIONAL)

FACTORY
INSTALLED
200 A
SERVICE
DISCONNECT
TYPE CSR

FACTORY
INSTALLED
400 A
SERVICE
DISCONNECT
TYPE DK

5

5

Type BR Wiring—Catalog Number HP404040SHA
400 AMPS
(320 AMPS
CONTINUOUS)

5

5

Metering Products

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Metering Products
Meter Breakers

5.9

Catalog Numbers HPC40SHL and HPC30SHL

5
5

N

400 Amps
(320 Amps
Continuous)

5

Bonded
Neutral

5

(Optional)
Factory/Field Installed
150 A Max. - HPC30SHL
200 A Max. - HPC40SHL
Service Disconnect
Type BW or CSR

5

(Optional)
100 A Max.
Service
Disconnect
Type BR or
BRH

5
5
5

Factory Installed
150 A or 200 A
Service Disconnect
Type CSR

5
5
5

Dimensions and Knockouts

5

Approximate Dimensions in Inches (mm)

5

Catalog Numbers HPC40SHL and HPC30SHL

5
5
5
5
5
5
5
5
5
5

Knockout Configurations and Dimensions for
HPC40SHL and HPC30SHL

5
5
5
5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-81

5.9
5
5

Metering Products
Meter Breakers

Approximate Dimensions in Inches (mm)
House Panel Dimensions and Knockouts—For All House Panels Except Those With HPCPREFIX

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
V1-T5-82

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Metering Products
Meter Breakers

5.9

Contents

Residential Meter Breakers

Description

Page

Residential Meter Breakers. . . . . . . . . . . . . . . . . .
Non-EUSERC Combination Service Entrance
Devices 100–200A Styles . . . . . . . . . . . . . . . . . .
Meets EUSERC Requirements Service Entrance
Devices 100–225A . . . . . . . . . . . . . . . . . . . . . . .
West Coast All-In-One Design. . . . . . . . . . . . . . . .
Mechanical Interlock Cover . . . . . . . . . . . . . . . . . .
House Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Commercial Safety Sockets
CH Style Renovation Solutions . . . . . . . . . . . . . . .
Aluminum Meter Breakers . . . . . . . . . . . . . . . . . .

5

V1-T5-37

5

V1-T5-39

5

V1-T5-48
V1-T5-59
V1-T5-65
V1-T5-75
V1-T5-86
V1-T5-87

5
5
5
5
5
5
5
5

Commercial Safety
Sockets
Product Description
A Commercial Safety
Socket is service entrance
equipment that consists of
a commercial meter socket
with a test block, and may
come with or without a
loadcenter type distribution
section.

5

Features, Benefits and Functions
Commercial Safety Sockets with
No Secondary Feeder

5
Overhead Combination Units

Underground Combination Units

5
5
5

Application Description
Eaton’s Commercial Safety
Sockets are typically used
where a single meter socket
or single meter socket with
a distribution section are
needed. These areas could
include a commercial
business, commercial office
building, individual retail
facilities and signs and street
lighting. Commercial Safety
Sockets are typically used in
EUSERC utility regions.

5

5
5
5
●

●
●

●

●

●

●

Ring type continuous duty
meter socket. 600 Vac
maximum, single- or
three-phase
100 and 200A units
Bussed connection from
meter socket to test block
For use with self-contained
watthour meter
Conform with EUSERC
standards
NEMA 3R construction for
indoor/outdoor applications
Units can be individually
mounted with provisions
for hub kits and pole
mounting

●

●

●
●

●

●

NEMA 3R construction for
indoor/outdoor applications
T-fuse protection, 480 Vac
maximum
Line at top, load at bottom
100 and 200A units
available up to 480 Vac
maximum
Circuit breaker protection
to 480 Vac maximum in
10, 22, 42 and 100 kAIC
ratings
Factory-cabled connection
from test block to line side
of tenant main

●
●
●

●

●

●

●

●

100 and 200A units
480 Vac maximum
NEMA 3R construction for
indoor/outdoor applications
Underground or overhead
feed
Provisions for selfcontained watthour meter
Bussed connection from
meter socket to test block
Tenant main disconnects
are available with circuit
breakers up to 480 Vac
maximum and T-fuse
mains, 240 Vac maximum
Load wires can exit top
or bottom

5
5
5
5
5
5
5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-83

5.9

Metering Products
Meter Breakers

5

Product Selection

5

Overhead and Underground Combination Units and Individual Units

5

CH127TB

Individual Safety Sockets—600V Maximum—No Secondary Feeder Devices

Phase, Wire

Maximum
Interrupting
Rating

Wire
Size

Catalog
Number

OH/UG

Single-phase, three-wire

1

#14–2/0

CH114TB

600

OH/UG

Three-phase, three-wire

1

#14–2/0

CH115TB

7

600

OH/UG

Three-phase, four-wire

1

#14–2/0

CH117TB

200

4

600

OH/UG

Single-phase, three-wire

1

#6–250 kcmil

CH124TB

200

5

600

OH/UG

Three-phase, three-wire

1

#6–250 kcmil

CH125TB

200

7

600

OH/UG

Three-phase, four-wire

1

#6–250 kcmil

CH127TB

Ampere
Rating

No. of
Jaws

AC
Voltage

Service

125

4

600

125

5

5

125

5

5
5

5
5

Commercial Safety Sockets with Provision for Main Circuit Breaker

5

Ampere
Rating

No. of
Jaws

AC
Voltage

Service

5

125

4

240

125

7

125

5
5
5
5
5

Phase, Wire

Feeder
Circuit
Breaker

Maximum
Interrupting
Rating

Wire
Size

Catalog
Number

OH

Single-phase, three-wire

Provision 2

4

#14–2/0

CH214MTBLB

208/120

OH

Three-phase, four-wire

Provision 2

4

#14–2/0

CH217MTBLB

4

240

UG

Single-phase, three-wire

Provision 2

4

#14–2/0

CHU214MTBLB

125

7

208/120

UG

Three-phase, four-wire

Provision 2

4

#14–2/0

CHU217MTBLB

200

4

120/240

OH

Single-phase, three-wire

Provision 3

5

#6–250 kcmil

CH224MTBLB

3

5

200

7

208/120

OH

Three-phase, four-wire

Provision

#6–250 kcmil

CH227MTBLB

200

4

120/240

UG

Single-phase, three-wire

Provision 3

5

#6–250 kcmil

CHU224MTBLB

200

7

208/120

UG

Three-phase, four-wire

Provision 3

5

#6–250 kcmil

CHU227MTBLB

Commercial Safety Sockets with Main Circuit Breaker Included

5

Phase, Wire

Feeder
Circuit
Breaker

Maximum
Interrupting
Rating

Wire
Size

Catalog
Number

OH

Three-phase, four-wire

EHD3100

14 kA

#14–2/0

CH217MTBM515

480/277

UG

Three-phase, four-wire

EHD3100

14 kA

#14–2/0

CHU217MTBMS15

480/277

OH

Three-phase, four-wire

JD3200

25 kA

#6–250 kcmil

CH227MTBHMS15

480/277

UG

Three-phase, four-wire

JD3200

25 kA

#6–250 kcmil

CHU227MTBHMS15

Ampere
Rating

No. of
Jaws

AC
Voltage

Service

100

7

480/277

5

100

7

5

200

7

200

7

5

5

Notes
1 If being protected by a fuse, the interrupting rating of the unit is limited to the fuse AIC rating. If being protected by a single- or three-phase,
600V breaker, the AIC is 14 kA; by a maximum 400A, single-phase, 240V breaker, the AIC is 18 kA; by a maximum 200A, single- or three-phase,
240V breaker, the AIC is 18 kA; by a maximum 125A, single-phase, 240V breaker, the AIC is 22 kA.
2 Order plug-on Type BR, BRH or BRHH circuit breaker separately.
3 Order Type CC breaker or CCH breaker separately.
4 Type BR = 10 kA; Type BRH = 22 kA; Type BRHH = 42 kA.
5 Type CCV = 10 kA; Type CCVH = 25 kA.

5
5
5
5
5
5
5
5
5
V1-T5-84

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

5.9

Metering Products
Meter Breakers

Underground Combination Units and Safety Socket Accessories
CHU227MTBP

5

Commercial Safety Sockets with T-Fuse Switch

5

Phase, Wire

Feeder
Circuit
Breaker

Maximum
Interrupting
Rating

Wire
Size

5

OH

Single-phase, three-wire

200 kA

#14–2/0

CH214MTBP

OH

Three-phase, four-wire

200 kA

#14–2/0

CH217MTBP

5

Ampere
Rating

No. of
Jaws

AC
Voltage

Service

100

4

120/240

100

7

208/120

100

4

120/240

UG

Single-phase, three-wire

200 kA

#14–2/0

CHU214MTBP

100

7

208/120

UG

Three-phase, four-wire

200 kA

#14–2/0

CHU217MTBP

200

4

120/240

OH

Single-phase, three-wire

200 kA

#6–250 kcmil

CH224MTBP

200

7

208/120

OH

Three-phase, four-wire

200 kA

#6–250 kcmil

CH227MTBP

200

4

120/240

UG

Single-phase, three-wire

200 kA

#6–250 kcmil

CHU224MTBP

200

7

208/120

UG

Three-phase, four-wire

200 kA

#6–250 kcmil

CHU227MTBP

5
5
5
5
5

Hubs
Description

Carton
Weight Lbs (kg)

Catalog
Number

5

Hub closure plate

3 (1.4)

ARP00002CHB

1.00-inch (25.4 mm) hub

3 (1.4)

ARP00003CH1

5

1.25-inch (31.8 mm) hub

3 (1.4)

ARP00004CH12

1.50-inch (38.1 mm) hub

3 (1.4)

ARP00005CH15

2.00-inch (50.8 mm) hub

3 (1.4)

ARP00006CH2

2.50-inch (63.5 mm) hub

3 (1.4)

ARP00007CH25

5
5
5
5

Jaws
Description

Part Number

5th jaw kit

CH50371

5
5

Note
Order Type CC or CHH breaker separately.

5
5
5
5
5
5
5
5
5
5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-85

5.9
5

Metering Products
Meter Breakers

CH Style Renovation Solutions

Contents
Description

5

Page

Residential Meter Breakers . . . . . . . . . . . . . . . . .
Non-EUSERC Combination Service Entrance
Devices 100–200A Styles. . . . . . . . . . . . . . . . . .
Meets EUSERC Requirements Service Entrance
Devices 100–225A . . . . . . . . . . . . . . . . . . . . . . .
West Coast All-In-One Design . . . . . . . . . . . . . . .
Mechanical Interlock Cover . . . . . . . . . . . . . . . . . .
House Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Commercial Safety Sockets . . . . . . . . . . . . . . . . .
CH Style Renovation Solutions
Aluminum Meter Breakers . . . . . . . . . . . . . . . . . .

5
5
5
5
5
5
5
5
5

CH Style Renovation Solutions

5

Product Description

5
5

●

●

5

●

5

●

●

5

Ring style meter
socket design
Provisional main breaker
or factory main breaker
available
Center top feed design
Exit bottom or top design
100A, 125A or 200A
ratings available

5

Product Selection

5

CH Style Retrofit Solutions

5

Description

Catalog
Number

100

CH, 22 circuit, provision, center top feed, exit top or bottom, flush, OH/UG

CMBE22P100BTFR

125

CH, 22 circuit, provision, center top feed, exit top or bottom, surface, OH/UG

CMBE22P125BTSR

5

125

CH, 22 circuit, provision, center top feed, exit top or bottom, flush, OH/UG

CMBE22P125BTFR

200

CH, 32/42 circuit, 200A main breaker, center top feed, exit top or bottom, semi-flush, OH/UG

CMBE3242B200BTS

5

200

CH, 32/42 circuit, 200A main breaker, center top feed, exit top or bottom, flush, OH/UG

CMBE3242B200BTFR

5

Ampere
Rating

5
5
5
5
5
5
5
V1-T5-86

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-37
V1-T5-39
V1-T5-48
V1-T5-59
V1-T5-65
V1-T5-75
V1-T5-83
V1-T5-87

Metering Products
Meter Breakers

5.9

Contents
Description

Page

Residential Meter Breakers . . . . . . . . . . . . . . . . . .
Non-EUSERC Combination Service Entrance
Devices 100–200A Styles . . . . . . . . . . . . . . . . . .
Meets EUSERC Requirements Service Entrance
Devices 100–225A . . . . . . . . . . . . . . . . . . . . . . .
West Coast All-In-One Design. . . . . . . . . . . . . . . .
Mechanical Interlock Cover . . . . . . . . . . . . . . . . . .
House Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Commercial Safety Sockets. . . . . . . . . . . . . . . . . .
CH Style Renovation Solutions . . . . . . . . . . . . . . .
Aluminum Meter Breakers

5

V1-T5-37

5

V1-T5-39

5

V1-T5-48
V1-T5-59
V1-T5-65
V1-T5-75
V1-T5-83
V1-T5-86

5
5
5
5
5
5
5
5

Aluminum Meter Breakers
Product Description

Features and Benefits

Eaton’s Aluminum Meter
Breaker enclosure and
external cover offers
excellent corrosion resistance
in the harshest coastal
environments. The meter
breaker’s light weight and
overhead/underground
design offers flexibility and
ease of installation.

●

●

●

Overhead/underground
design provides flexibility
with wiring options
Steel meter guides are
standard, which provides a
means of easy installation
of the utility glass bulb
meter into the meter’s
jaws
Main Lug Only design
includes six two-pole
breaker locations, which
complies with National
Electrical Code 225.33
(maximum number of
disconnects)

●

●

●

●

●

Distribution section
accepts BR branch
breakers
Single-phase, three-wire
120/240 Vac applications
Hub closure plate is
provided, attached to the
top of the device
Optional fifth jaw can be
applied to 3 o’clock or
9 o’clock meter socket
position
10-year warranty

●

●

For customer support,
contact Eaton’s Technical
Resource Center at
1-877-ETN-CARE
For additional information
or to place an order,
contact your local Eaton
representative or visit us
at www.eaton.com

5
5
5
5
5
5
5
5
5
5

Catalog Number Selection

5

Meter Breakers

5

MB 12 12 L 200 BT S A

5
Material
A = Aluminum

Meter Breaker Type
MB = 1-inch (25.4 mm) BR Type

5

Mounting
S = Surface

Spacing
Number of spaces
Poles
Maximum number of poles

5

Main
L = Lug

5

Breaker Feed
BT = Bottom and top

5

Amperes
Amperage of unit

5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-87

5.10
5

Metering Products
Group Metering

Systems for Residential and Commercial Application

Description

5

Systems for Residential and Commercial
Applications
Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type CCV 120/240V Tenant Main Circuit Breaker .
Type CV 120/240V Tenant Main Circuit Breaker . .
Meter Packs—1MP, 1MM and 3MM Main
Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . .
Main Service Modules . . . . . . . . . . . . . . . . . . . . .
Surge Metering. . . . . . . . . . . . . . . . . . . . . . . . . . .
Residential Meter Stacks . . . . . . . . . . . . . . . . . . .
1MP, 1MM and 3MM Main Tenant
Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . .
Phase Balanced Stack. . . . . . . . . . . . . . . . . . . . . .
Commercial Meter Stack Modules . . . . . . . . . . . .
35MM, 37MM, 35SS and 37SS
Main Tenant Circuit Breakers . . . . . . . . . . . . . . .

5
5
5
5
5
5
5
5
5

Systems for Residential and Commercial Applications

5

Product Description

Application Description

Group metering is a service
entrance product line that
consists of a main device
and multiple meter sockets
in one enclosure or several
connected enclosures.
Group metering allows the
customer to install a multiple
tenant-metering device in
one location while providing
a space and installation
cost savings.

Eaton’s Electrical Sector
offers two group metering
designs—Meter Packs and
Gangable Metering. Meter
Packs, also called All-in-Ones,
consist of main lugs and up
to six meter sockets in one
enclosure. Meter Packs are
supplied as one complete
unit and the user cannot
“add” additional meter
sockets to the unit in the
future. The most common
application for Meter Packs
is garden apartments,
small condominiums and
townhouses where six or
less units are metered
through one centrally
located Meter Pack.

5
5
5
5
5
5

Contents

5
5
5
5
5
5
5

Gangable Metering
(Main Service Modules
and Meter Stacks)
The second type of group
metering is Gangable
Metering, which consists of
a Main Service Module used
in conjunction with a Meter
Stack to make a custom
metering lineup. The Main
Service Module can be main
lug, main circuit breaker, main
fusible switch or bolted
pressure switch. The Meter
Stack is offered with various
meter sockets and bus
ratings. This type of custom
lineup allows the owner to
add/remove meter sockets
and main devices to meet
future need. Gangable
Metering is often used in
large condominiums, strip
malls and light commercial
applications where more
than six units are metered,
or there will be a future
need to add more units.

5
5
5
5
5
V1-T5-88

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Page

V1-T5-90
V1-T5-95
V1-T5-96
V1-T5-98
V1-T5-101
V1-T5-115
V1-T5-116
V1-T5-125
V1-T5-126
V1-T5-127
V1-T5-134

5.10

Metering Products
Group Metering

Features, Benefits and Functions
Clip-Tight™ Socket

5
Field Phase Balancing

Lever Bypass

Main Tenant Breaker Cover

5
5
5
5
5
5

Clip-Tight Socket

Field Phase Balancing

Lever Bypass

Eaton’s series of 1MP, 1MM,
3MM metering devices
incorporate the only socket
base in the industry without
fasteners. This component
uses jaws on both sides of a
thermoplastic polyester glass
fiber reinforced (PBT) base,
eliminating the need
for self-tapping screw
connections to vertical
busbars.

Due to popular incoming
three-phase voltage systems
and single-phase outgoing
loads, installers have the
option to field phase balance
on the individual stack (A-B,
B-C, A-C). This feature
eliminates the chance of
installing an incorrectly
phased device due to its
versatility.

Due to commercial
requirements, Eaton offers
a lever bypass (as standard)
on all 35MM and 37MM
devices. Each socket base
consists of a lever bypass,
which also releases the jaws
(when lever is engaged in
bypass position), enabling
utility company mechanics to
easily remove and/or insert
utility meter.

One-Piece Vertical Busbar

Horn and Manual Bypass

Test Bypass Disconnects

5
5
5
Main Tenant Breaker Cover

Each tenant circuit breaker
is protected by a lockable
raintight cover that secures
the breaker against
unauthorized operation. The
tenant breaker cover is a high
impact plastic to resist wear,
rusting and corrosion.

5
5
5
5
5

Mounting Features

5
5
5
5
5

Horn and Manual Bypass

One-Piece Vertical Busbar

Eaton’s series of 1MP, 1MM,
3MM meter stacks embody
a one-piece busbar
construction to each socket,
as well as a one-piece cross
bus to each tenant main.
Because the Eaton design
uses the Clip-Tight meter
socket and does not have
busbar joints, the chance of
hot spots occurring is virtually
eliminated.

With an increasing demand for
uninterrupted power, Eaton’s
series of 1MP, 1MM and
3MM meter sockets offer
horn (ringless style) and
manual (ring style) fieldinstallable bypass accessories.
These accessories provide
uninterrupted tenant service
if a meter is pulled for
inspection or replacement.

Mounting Features

A standard mounting rail and
factory-installed swing away
feet speed up and simplify
installation.
Test Bypass Disconnects

Eaton also provides
commercial meter stacks
with EUSERC required testbypass disconnects (35SS
and 37SS). This bypass is
used in the same applications
as the lever bypass and it is
required by EUSERC utilities.

Standards and Certifications
●

UL listed

5
5
5
5
5
5
5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-89

5.10
5

Metering Products
Group Metering

Contents

Meter Pack

Description

5

Systems for Residential and Commercial
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Meter Packs
Type CCV 120/240V Tenant Main Circuit Breaker .
Type CV 120/240V Tenant Main Circuit Breaker . .
Meter Packs—1MP, 1MM and 3MM Main
Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . .
Main Service Modules . . . . . . . . . . . . . . . . . . . . .
Surge Metering. . . . . . . . . . . . . . . . . . . . . . . . . . .
Residential Meter Stacks . . . . . . . . . . . . . . . . . . .
1MP, 1MM and 3MM Main Tenant
Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . .
Phase Balanced Stack. . . . . . . . . . . . . . . . . . . . . .
Commercial Meter Stack Modules . . . . . . . . . . . .
35MM, 37MM, 35SS and 37SS
Main Tenant Circuit Breakers . . . . . . . . . . . . . . .

5
5
5
5
5
5
5
5
5

Meter Packs

5

Product Overview

5

●

5
5

●

5
5

●

5
5
5
5
5
5
5

●

●

●

Eaton’s 1MP units are
self-contained (main
terminal box included) for
installations requiring up to
six meter socket positions
in a single enclosure
Units are not gangable
with any other metering
device
Approved by major power
companies, UL listed,
suitable as service
equipment and meet the
service and electrical
requirements of EUSERC
and CECHA
Series rating up to
100 kAIC
All ringless cover
devices include fifth
jaw as standard
Ring type devices do
not include fifth jaw as
standard. Order 1MM5JK
if needed

●
●

●

●

●

●

●

●

Bondable neutral
120/240 Vac, single-phase
three-wire metering device
Up to 600A maximum
horizontal bus rating
Incoming lugs not included
(phase A, phase B and
neutral)
Indoor/outdoor
construction
Provision for two-pole
breaker (plug-on type for
125A sockets and bolt-on
type for 200A sockets)—
circuit breakers not
included
Underground incoming
feed
Aluminum or copper bus

5
5
5
5
5
5
V1-T5-90

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Page
V1-T5-88
V1-T5-95
V1-T5-96
V1-T5-98
V1-T5-101
V1-T5-115
V1-T5-116
V1-T5-125
V1-T5-126
V1-T5-127
V1-T5-134

Metering Products
Group Metering

5.10

Catalog Number Selection

5
1 M P 4 12 4 R C
Single-Phase

Type of Metering
MP = Meter pack
Number of Meters
2, 3, 4, 5 or 6
Blank = Accessory
Ampere Rating
12 = 125A
20 = 200A
Blank = Accessory

5
5

Bus Material
C = Copper bus
Blank = Aluminum bus

5
5

Security or Accessory Code
R= Ring
RRL = Ringless
RRLB = Ringless with horn bypass
LK = Lug kit (accessory)
SC = Crimp lug landing pad kit
(accessory)

5
5
5

Bus Ampere Rating
2 = 200A
4 = 400A
6 = 600A
Blank = Accessory

5
5

When Ordering:
1. Determine catalog number of the basic device.

5

2. Include Lug Kit for incoming section. See Page V1-T5-94.
3. Find quantity and catalog numbers for tenant circuit breakers. (Order one breaker per socket.) See Page V1-T5-94.

5

4. Select required accessories. See Page V1-T5-136.

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-91

5.10

Metering Products
Group Metering

5

Product Selection

5

Meter Packs

5

Aluminum Bus—Main Lugs Not Included—See Page V1-T5-94

5

Socket
Ampere
Rating

5
5

Number of
Meter
Sockets

Bus
Ampere Rating

Main Tenant
Breaker Type
(See Page V1-T5-94)

Catalog
Number

Semi-Flush
Flange Kit
Catalog Number

Ring Style Meter Socket Covers 1
125 2

24

200

125 2

3

400

2

Plug-on type
BR2_
BRH2_
BRHH2_

1MP2122R 58

1MPSFK1

1MP3124R 6

1MPSFK2

6

1MPSFK2

5

125

4

400

125 2

54

600

1MP5126R 6

1MPSFK3

5

125 2

64

600

1MP6126R 6

1MPSFK3

5

200 3

2

400

1MP2204R 6

1MPSFK4

200 3

3

600

1MP3206R 6

1MPSFK5

5

200 3

4

600

1MP4206R 6

1MPSFK5

200 3

5

600

1MP5206R 6

1MPSFK6

5

200 3

6

600

1MP6206R 6

1MPSFK6

1MP2122RRL 58

1MPSFK1

1MP3124RRL 6

1MPSFK2

1MP4124RRL 6

1MPSFK2

Bolt-on type
CCV2_X
CCVH2_X
CVS2_XMM
CV2_XMM
CVH2_XMM

1MP4124R

Ringless Style Meter Socket Covers

7

5

125

2

200

5

125

3

400

125

4

400

5

125

5

600

1MP5126RRL 6

1MPSFK3

125

6

600

1MP6126RRL 6

1MPSFK3

5

200

2

400

1MP2204RRL 6

1MPSFK4

200

3

600

1MP3206RRL 6

1MPSFK5

6

1MPSFK5

1MP5206RRL 6

1MPSFK6

1MP6206RRL 6

1MPSFK6

1MP2122RRLB 58

1MPSFK1

1MP3124RRLB 69

1MPSFK2

1MP4124RRLB 69

1MPSFK2

5

200

4

600

5

200

5

600

200

6

600

5

Ringless Style Covers with Horn Bypass 7

Plug-on type
BR2_
BRH2_
BRHH2_

Bolt-on type
CCV2_X
CCVH2_X
CVS2_XMM
CV2_XMM
CVH2_XMM

125

2

200

5

125

3

400

5

125

4

400

125

5

600

1MP5126RRLB 69

1MPSFK3

69

1MPSFK3

1MP2204RRLB 69

1MPSFK4

1MP3206RRLB 69

1MPSFK5

1MP4206RRLB 69

1MPSFK5

1MP5206RRLB 69

1MPSFK6

1MP6206RRLB 69

1MPSFK6

5

125

6

600

200

2

400

5

200

3

600

200

4

600

200

5

600

200

6

600

5
5
5
5
5
5
5

Plug-on type
BR2_
BRH2_
BRHH2_

1MP4206RRL

1MP6126RRLB
Bolt-on type
CCV2_X
CCVH2_X
CVS2_XMM
CV2_XMM
CVH2_XMM

Notes
1 Ring Style Meter Packs do not come with fifth jaw. Order 1MM5JK if needed.
2 To change in field from ring to ringless—order 1MMRC125.
3 To change in field from ring to ringless—order 1MMRC200.
4 To change from ring to ringless covers, the top socket only in 2, 5 and 6 socket designs—order 1MMRC125T. Top socket only.
5 Main lugs included. #6–300 kcmil. (Optional lugs are not available.)
6 For overhead use, order DS_H2 type hub.
7 Fifth jaw factory installed at 9 o’clock position.
8 For overhead use, order DS type hub.
9 To order with raceway provision in bottom endwall, add “T” suffix to the catalog number. Trough accessory catalog number is 1008934CH.
See Page V1-T5-94 for Main Lug Kit selection and Wire Sizes.

5
V1-T5-92

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Metering Products
Group Metering

5.10

Copper Bus—Main Lugs Not Included—See Page V1-T5-94
Socket
Ampere
Rating

Number of
Meter
Sockets

Bus
Ampere Rating

Main Tenant
Breaker Type
(See Page V1-T5-94)

5

Semi-Flush
Flange Kit
Catalog Number

Catalog
Number

5

Ring Style Meter Socket Covers 1
125 2

24

1MP2122RC 6

1MPSFK1

7

1MPSFK2

1MP4124RC 7

1MPSFK2

600

1MP5126RC 7

1MPSFK3

600

1MP6126RC 7

1MPSFK3

200

2

3

400

125 2

4

400

125 2

54

125 2

64

200 3

2

400

200 3

3

600

200 3

4

600

125

3

5

600

200 3

6

600

200

Plug-on type
BR2_
BRH2_
BRHH2_

Bolt-on type
CCV2_X
CCVH2_X
CVS2_XMM
CV2_XMM
CVH2_XMM

1MP3124RC

1MP2204RC 7

1MPSFK4

1MP3206RC 7

1MPSFK5

1MP4206RC 7

1MPSFK5

7

1MPSFK6

1MP6206RC 7

1MPSFK6

1MP2122RRLC 7

1MPSFK1

1MP3124RRLC 7

1MPSFK2

1MP4124RRLC 7

1MPSFK2

1MP5126RRLC 7

1MPSFK3

1MP6126RRLC 7

1MPSFK3

1MP2204RRLC 7

1MPSFK4

1MP5206RC

5
5
5
5
5
5
5

Ringless Style Meter Socket Covers 5
125

2

200

125

3

400

125

4

400

125

5

600

125

6

600

200

2

400

200

3

600

200

4

600

200

5

600

200

6

Plug-on type
BR2_
BRH2_
BRHH2_

Bolt-on type
CCV2_X
CCVH2_X
CVS2_XMM
CV2_XMM
CVH2_XMM

600

5
5
5
5

1MP3206RRLC 7

1MPSFK5

1MP4206RRLC 7

1MPSFK5

1MP5206RRLC 7

1MPSFK6

7

1MPSFK6

5

7

1MPSFK1

1MP3124RRLBC 7

1MPSFK2

5

1MP4124RRLBC 7

1MPSFK2

1MP5126RRLBC 7

1MPSFK3

1MP6126RRLBC 7

1MPSFK3

1MP2204RRLBC 7

1MPSFK4

1MP3206RRLBC 7

1MPSFK5

1MP4206RRLBC 7

1MPSFK5

1MP5206RRLBC 7

1MPSFK6

1MP6206RRLBC 7

1MPSFK6

1MP6206RRLC

5

Ringless Style Covers with Horn Bypass 5
125

2

200

125

3

400

125

4

400

125

5

600

125

6

600

200

2

400

200

3

600

200

4

600

200

5

600

200

6

600

Plug-on type
BR2_
BRH2_
BRHH2_

Bolt-on type
CCV2_X
CCVH2_X
CVS2_XMM
CV2_XMM
CVH2_XMM

1MP2122RRLBC

5
5
5
5
5
5

Notes
1 Ring Style Meter Packs do not come with fifth jaw. Order 1MM5JK if needed.
2 To change in field from ring to ringless—order 1MMRC125.
3 To change in field from ring to ringless—order 1MMRC200.
4 To change in field from ring to ringless covers, the top socket only in 5 to 6 socket design—order 1MMRC125T.
Top socket only—other sockets see 2.
5 Fifth jaw factory installed at 9 o’clock position.
6 For overhead use, order DS_H2 type hub.
7 For overhead use, order DS_MH type hub.

5
5
5
5
5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-93

5.10
5

1MPLK3

Metering Products
Group Metering

Main Lug Selection—Field-Installed Lugs for 400 or 600A Main Bus

5

Line Lug and Wire Sizes
Order Separately and Field Install

Line Lug Kit Catalog Number
Order Three Kits
(For Two Lines and Neutral)

5

(1) #6–600 kcmil or (2) 2/0–250 kcmil

1MPLK1

(2) 250–500 kcmil

1MPLK3

5

(3) #4–300 kcmil

1MPLK4 1

(1) 750 kcmil

1MPLK2 2

5

Crimp lug landing pad 250–750 kcmil

1MPSC1 1

5

Wire Sizes—Neutral and Ground Lugs

5

Description

Wire Size,
Al/Cu

Catalog
Number

5

Neutral—125A meter pack

#6–2/0

—

Neutral—200A meter pack

#1/0–300 kcmil

—

5

Equipment ground bar—125A meter pack

#14–#2

—

Equipment ground bar—200A meter pack

#14–2/0

—

5

Optional ground bar

#6–2/0

1MMGBK

5

Notes
1 This kit comes with three pads for two lines and neutral. Each pad will accept one or two crimp
lugs. Cannot be used on 1MP2122R, RL, RC and RLB EUSERC underground termination.
2 This lug is not UL listed.

5

Each stack includes a neutral and ground bar. If an extra ground bar is needed, order 1MMGBK.

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
V1-T5-94

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Metering Products
Group Metering

5.10

Contents

Type CCV Tenant Main Circuit Breaker

Description

Page

Systems for Residential and Commercial
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type CCV 120/240V Tenant Main Circuit Breaker
Type CV 120/240V Tenant Main Circuit Breaker . .
Meter Packs—1MP, 1MM and 3MM Main
Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . .
Main Service Modules . . . . . . . . . . . . . . . . . . . . .
Surge Metering . . . . . . . . . . . . . . . . . . . . . . . . . . .
Residential Meter Stacks. . . . . . . . . . . . . . . . . . . .
1MP, 1MM and 3MM Main Tenant
Circuit Breakers. . . . . . . . . . . . . . . . . . . . . . . . . .
Phase Balanced Stack . . . . . . . . . . . . . . . . . . . . . .
Commercial Meter Stack Modules . . . . . . . . . . . .
35MM, 37MM, 35SS and 37SS
Main Tenant Circuit Breakers . . . . . . . . . . . . . . .

V1-T5-88
V1-T5-90
V1-T5-96
V1-T5-98
V1-T5-101
V1-T5-115
V1-T5-116

Features

Eaton offers Type CCV
(10 and 22 kAIC) and Type CV
(42, 65 and 100 kAIC) family
of circuit breakers as the
primary tenant main breakers
used in most group metering
applications.

●

●

Product Description
Eaton’s residential products
Type CCV circuit breaker is
available in two-pole
configurations from 100A to
225A in 10 and 22 kAIC
ratings.

●

5
5
5
5
5
5

V1-T5-134

5

5
5

Standards and Certifications

Ratings—120/240 Vac,
two-pole, through 225
continuous amperes,
calibrated at 40°C
Tripping characteristics—
thermal-magnetic trip,
calibrated and sealed after
assembly. Indirectly heated
thermal tripping bimetal
elements
Interrupting capacity at
120/240 Vac. Type CCV—
10 kAIC rms symmetrical.
Type CCVH—25 kAIC rms
symmetrical

5

V1-T5-125
V1-T5-126
V1-T5-127

Type CCV 120/240V Tenant Main Circuit Breaker
Product Overview

5

●

●

●

Handles—trip-free with
ON-TRIPPED-OFF
positions. Reset past OFF
is required to latch breaker
contacts after tripping
Terminals—standard
lugs (wire connectors)
suitable for copper or
aluminum wire
Backward compatibility—
Type CCV and CCVH
retains same profile and
footprint as the CC and
CCH breaker, allowing use
in the same applications

●

Complies with UL Standard
489. Breakers are listed
under UL File #E7819

5
5
5
5
5
5
5
5
5

Product Selection

5

Type CCV 120/240V Tenant Main Circuit Breaker

5

Two-Pole Breaker
Ampere
Rating

Wire Size Range,
Al/Cu

10 kAIC

25 kAIC

100

#2–300 kcmil

CCV2100X

CCVH2100X

125

CCV2125X

CCVH2125X

150

CCV2150X

CCVH2150X

175

CCV2175X

CCVH2175X

200

CCV2200X

CCVH2200X

225

CCV2225X

CCVH2225X

5
5
5
5
5

Modification Codes
●
X—load side terminals only

5
5
5
Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-95

5.10
5

Metering Products
Group Metering

Contents

Type CV Tenant Main Circuit Breaker

Description

5

Systems for Residential and Commercial
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type CCV 120/240V Tenant Main Circuit Breaker .
Type CV 120/240V Tenant Main Circuit Breaker . .
Meter Packs—1MP, 1MM and 3MM Main
Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . .
Main Service Modules . . . . . . . . . . . . . . . . . . . . .
Surge Metering. . . . . . . . . . . . . . . . . . . . . . . . . . .
Residential Meter Stacks . . . . . . . . . . . . . . . . . . .
1MP, 1MM and 3MM Main Tenant
Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . .
Phase Balanced Stack. . . . . . . . . . . . . . . . . . . . . .
Commercial Meter Stack Modules . . . . . . . . . . . .
35MM, 37MM, 35SS and 37SS
Main Tenant Circuit Breakers . . . . . . . . . . . . . . .

5
5
5
5
5
5
5
5
5

Type CV 120/240V Tenant Main Circuit Breaker

5

Product Overview

Features

Eaton offers Type CCV
(10 and 22 kAIC) and Type CV
(42, 65 and 100 kAIC) family
of circuit breakers as the
primary tenant main breakers
used in most group metering
applications.

●

5
5
5
5
5
5
5

●

Product Description
Eaton’s residential products
Type CV molded-case circuit
breaker is available in twoand three-pole configurations
from 60A to 225A in 42, 65
and 100 kAIC ratings.

●

5
5
5

●

5
5
●

5
5

Ratings—120/240 Vac,
two- and three-pole,
through 225 continuous
amperes, calibrated
at 40°C
Tripping characteristics—
thermal-magnetic trip,
calibrated and sealed after
assembly. Indirectly heated
thermal tripping bimetal
elements; includes pushto-test button for routine
preventive maintenance
Interrupting capacity at
120/240 Vac
●
Type CVS—42,000A rms
symmetrical
●
Type CV—65,000A rms
symmetrical
●
Type CVH—100,000A
rms symmetrical
Handles—trip-free with
ON-TRIPPED-OFF
positions. Reset past OFF
is required to latch breaker
contacts after tripping
Terminals—standard
lugs (wire connectors)
suitable for copper or
aluminum wire

Standards and Certifications
●

Complies with UL Standard
489. Breakers are listed
under UL File #E7819

5
5
5
5
V1-T5-96

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Page
V1-T5-88
V1-T5-90
V1-T5-95
V1-T5-96
V1-T5-98
V1-T5-101
V1-T5-115
V1-T5-116
V1-T5-125
V1-T5-126
V1-T5-127
V1-T5-134

5.10

Metering Products
Group Metering

Product Selection
Type CV Two-Pole Tenant Main Circuit Breakers
Main Tenant
Number Circuit Breaker
of Poles Ampere Rating

Wire Size 42 kAIC
Range,
Catalog
Al/Cu
Number

2

#6–4/0

60

5

Type CV Three-Pole Tenant Main Circuit Breakers

65 kAIC

100 kAIC

Catalog
Number

Catalog
Number

CVS2060XMM CV2060XMM CVH2060XMM

5

Main Tenant
Number Circuit Breaker
of Poles Ampere Rating

Wire Size 42 kAIC
Range,
Catalog
Al/Cu
Number

65 kAIC

100 kAIC

Catalog
Number

Catalog
Number

5

3

#6–4/0

CVS3060X

CV3060X

CVH3060X

5

60

70

CVS2070XMM CV2070XMM CVH2070XMM

70

CVS3070X

CV3070X

CVH3070X

80

CVS2080XMM CV2080XMM CVH2080XMM

80

CVS3080X

CV3080X

CVH3080X

90

CVS2090XMM CV2090XMM CVH2090XMM

90

CVS3090X

CV3090X

CVH3090X

100

CVS2100XMM CV2100XMM CVH2100XMM

100

CVS3100X

CV3100X

CVH3100X

125

CVS2125XMM CV2125XMM CVH2125XMM

125

CVS3125X

CV3125X

CVH3125X

150

CVS2150XMM CV2150XMM CVH2150XMM

150

CVS3150X

CV3150X

CVH3150X

175

CVS2175XMM CV2175XMM CVH2175XMM

175

CVS3175X

CV3175X

CVH3175X

200

CVS2200XMM CV2200XMM CVH2200XMM

200

CVS3200X

CV3200X

CVH3200X

225

CVS2225XMM CV2225XMM CVH2225XMM

225

CVS3225X

CV3225X

CVH3225X

5
5
5
5
5

Accessories

5

Field Installable

Description

Catalog
Number

Two-pole 300 kcmil with terminal shield

2TA225CVK

Three-pole 300 kcmil with terminal shield

3TA225CVK

Replacement mounting hardware kit for 200A 1MP, 1MM and 3MM units

1MMCBK

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-97

5.10
5

Metering Products
Group Metering

Contents

Main Tenant Circuit Breakers

Description

5
5
5
5
5
5
5
5
5
5

Meter Packs—1MP, 1MM and 3MM Main Tenant Circuit Breakers

5

Product Description

5
5
5

Page

Systems for Residential and Commercial
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type CCV 120/240V Tenant Main Circuit Breaker .
Type CV 120/240V Tenant Main Circuit Breaker . .
Meter Packs—1MP, 1MM and 3MM Main
Tenant Circuit Breakers
Main Service Modules . . . . . . . . . . . . . . . . . . . . .
Surge Metering. . . . . . . . . . . . . . . . . . . . . . . . . . .
Residential Meter Stacks . . . . . . . . . . . . . . . . . . .
1MP, 1MM and 3MM Main Tenant
Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . .
Phase Balanced Stack. . . . . . . . . . . . . . . . . . . . . .
Commercial Meter Stack Modules . . . . . . . . . . . .
35MM, 37MM, 35SS and 37SS
Main Tenant Circuit Breakers . . . . . . . . . . . . . . .

V1-T5-88
V1-T5-90
V1-T5-95
V1-T5-96

V1-T5-101
V1-T5-115
V1-T5-116
V1-T5-125
V1-T5-126
V1-T5-127
V1-T5-134

Specific main tenant circuit
breakers that are to be
used in meter packs (1MP),
residential meter stacks
(1MM) and three-phase in
single-phase out meter
stacks (3MM).

5
5

Product Selection

5

Main Tenant
Circuit Breaker
Ampere Rating

10 kAIC

22 kAIC

25 kAIC

65 kAIC

100 kAIC

Number
of Poles

Catalog
Number 1

Catalog
Number

Catalog
Catalog
Number 1234 Number 234

Catalog
Number 234

Catalog
Number 234

2

60

BR260

BRH260

—

BRHH260

—

—

2

70

BR270

BRH270

—

BRHH270

—

—

2

80

BR280

BRH280

—

BRHH280

—

—

2

90

BR290

BRH290

—

BRHH290

—

—

2

100

BR2100

BRH2100

—

BRHH2100

—

—

2

110

BR2110

BRH2110

—

BRHH2110

—

—

2

125

BR2125

BRH2125

—

BRHH2125

—

—

2

60

—

—

CVS2060XMM

CVS2060XMM

CV2060XMM

CVH2060XMM

2

70

—

—

CVS2070XMM

CVS2070XMM

CV2070XMM

CVH2070XMM

2

80

—

—

CVS2080XMM

CVS2080XMM

CV2080XMM

CVH2080XMM

2

90

—

—

CVS2090XMM

CVS2090XMM

CV2090XMM

CVH2090XMM

5

2

100

CCV2100X

—

CCVH2100X

CVS2100XMM

CV2100XMM

CVH2100XMM

2

125

CCV2125X

—

CCVH2125X

CVS2125XMM

CV2125XMM

CVH2125XMM

5

2

150

CCV2150X

—

CCVH2150X

CVS2150XMM

CV2150XMM

CVH2150XMM

2

175

CCV2175X

—

CCVH2175X

CVS2175XMM

CV2175XMM

CVH2175XMM

5

2

200

CCV2200X

—

CCVH2200X

CVS2200XMM

CV2200XMM

CVH2200XMM

5
5
5

Description
Plug-On Type
Plug-on type circuit breakers used
with 1MP, 1MM, and 3MM 125A
modular metering stacks

5
5
5
5

5
5

42 kAIC

Bolt-On Type
Bolt-on type circuit breakers used
with 1MP, 1MM, and 3MM 200A
modular metering stacks

Notes
1 #2–300 kcmil wire size range for CCV and CCVH tenant main circuit breakers.
2 “MM” suffix indicates mounting hardware kit is included as standard with tenant main breaker.
3 1MMCBK replacement mounting hardware kit. One kit is needed per breaker. Mounting hardware kit ships standard with breaker “MM” suffix offering.
4 #6–4/0 kcmil wire size range for CVS, CV and CVH tenant main circuit breakers. If #2–300 kcmil is needed, order 2TA225CVK. One kit needed per breaker.

V1-T5-98

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Metering Products
Group Metering

5.10

Dimensions and Knockouts

5

Approximate Dimensions in Inches (mm)

5

1MP, 125 Ampere Meter Packs—Aluminum and Copper Bus
24.260

5

.450

5.610

"W"
"X"
"Y"
"Z"

.450

5.610

5.125

11.880
9.380
5.000

2.560

5
5
5

3.000

3.000
36.130

3.00 (76.2)

"Z" = C
L of 1/2" Ring
"Y" = C
L of 1-1/2" Ring
"X" = C
L of 1-1/2" Ring
"W" = C
L of 4" Ring

5

8.000

5.125

24.08 (611.6)

4.565

4.690
7.015

"W"

5

27.000

3.615
4.690
7.005

"X"
"Y"

5

5, 6 Meter Device

.695

4.555

5

Concentric
Knockouts
1/2" Knockout
Concentric Knockouts
1", 1-1/4", 1-1/2", Knockout

Concentric
Knockouts
2-1/2", 3", 3-1/2", 4 "
Knockout

Concentric
Knockouts
1/2" Knockout

41.600

9.000

(1) Knockout
for 1-1/2, 2,
2-1/2 Conduit 3, 4 Meter Device

Concentric Knockouts
1", 1-1/4", 1-1/2", Knockout
Concentric Knockouts
2-1/2", 3", 3-1/2", 4 " Knockout
14.460

5

3.625

(3) Knockout
for 1, 1-1/4, 1-1/2
Conduit

6.560

7.015

5

12.550

9.000

48.290

12.552

9.000

9.000

9.000

34.250
To CL of Wall Mtg. Screw
21.699
CL Meter ToCL Rail Mtg. Screw

2.025

3.140

"Z"

5

36.280

Mtn. for 2, 2-1/2, 3"
C-H Conduit Hubs

5

6.380
5.900

.060
2.250

5

1", 1-1/4", 1-1/2"
Knockouts
(6 Required)

1/2" Knockout
2.625
2.313

5

23.750

1-1/2", 2",
2-1/2", 3"
Knockouts

34.180

5
.875

5

57 Mtg Holes
4 Places

1, 1-1/4, 1-1/2" KO
6 Places

1.500
1.438
4.375

4.389
2.313

5

2.750

1.880

1.806

5

1.440

1.063
.438

5

2.750

2.880

4.000

3.063 Dia.
Hub Opening

5
2.277

5

3.688
3.250

5
2.563
6.500

Bottom Endwall Knockouts for Units with "T" Suffix
3, 4 Meter Device

3.063

5

Top View

5
5

3.250

2.563
6.500

5

Bottom Endwall Knockouts for Units with "T" Suffix
5, 6 Meter Device

5
5
Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-99

5.10

Approximate Dimensions in Inches (mm)
1MP, 200 Ampere Meter Packs—Aluminum and Copper Bus
25.480
25.480

5

2.015

5

5
5

2 Meter Device

5
5

3.125

7.015

5

12.125

52.415

12.125

5

Typ.
3.000

5.125
24.080

"Z" = C
L of 1/2" Ring
"Y" = C
L of 1-1/2" Ring
C
"X" = L of 1-1/2" Ring
"W" = C
L of 4" Ring

5, 6 Meter Device
Concentric
Knockouts
2-1/2", 3", 3-1/2",
4 " Knockout

Concentric
Knockouts
1", 1-1/4", 1-1/2",
2" Knockout

Concentric Knockouts
1/2" Knockout
4.565

27.000

.695

3.625

"W"
"X"
"Y"
"Z"

.450

5.610

3.000

8.000

3.000

7.015

4.690

6.555

5
5

5.610

18.425

5

5

.450

2, 3 & 4 Meter Endwall

5

5

"W"
"X"
"Y"
"Z"

3.250

2.563
6.500

38.635

Bottom Endwall Knockouts
for Units with "T" Suffix
2, 3, 4 Meter Device

5
5
5

3.250

5

2.563
6.500

Bottom Endwall Knockouts for Units with "T" Suffix
5, 6 Meter Device

5
5
V1-T5-100

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

7.005

5

3.615

4.690

5

3, 4 Meter Device

Concentric Knockouts
1/2" Knockout
Concentric Knockouts
1", 1-1/4", 1-1/2", 2" Knockout
Concentric Knockouts
4.555
15.000
2-1/2", 3", 3-1/2", 4 " Knockout

2.015

5

5

(4) Knock Out
For 1", 1-1/4", 1-1/2", 2"
Conduit

38.755

5

64.535

12.125
12.125

18.400

5

18.425

5

15.826
CL Meter To CL Rail Mtg. Screw

12.155

5

12.125

2.015

34.250
To CL of Wall Mtg. Screw

5

Group Metering

42.685

5

Metering Products

Metering Products
Group Metering

5.10

Contents
Description

Page

Systems for Residential and Commercial
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type CCV 120/240V Tenant Main Circuit Breaker .
Type CV 120/240V Tenant Main Circuit Breaker . .
Meter Packs—1MP, 1MM and 3MM Main
Tenant Circuit Breakers. . . . . . . . . . . . . . . . . . . .
Main Service Modules
Surge Metering . . . . . . . . . . . . . . . . . . . . . . . . . . .
Residential Meter Stacks . . . . . . . . . . . . . . . . . . .
1MP, 1MM and 3MM Main Tenant
Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . .
Phase Balanced Stack . . . . . . . . . . . . . . . . . . . . . .
Commercial Meter Stack Modules . . . . . . . . . . . .
35MM, 37MM, 35SS and 37SS
Main Tenant Circuit Breakers . . . . . . . . . . . . . . .

V1-T5-88
V1-T5-90
V1-T5-95
V1-T5-96
V1-T5-98
V1-T5-115
V1-T5-116

●
●
●

●
●

●

Main terminal box
Main circuit breaker
Main bolted pressure
switch
Main fusible switch
Main fusible switch with
pull box
Underground pull box

Application Description
Main Circuit Breakers with
Busway Connections
The Service Entrance Product
Team announces the
availability of both main
fusible switch and main
circuit breaker group
metering mains with busway
connections. This offering
provides us with the ability
to offer multiple tenant
metering in high rise
apartment buildings where
riser busway is used.

5
5
5
5
5
5

V1-T5-125
V1-T5-126
V1-T5-127

5

V1-T5-134

5

5
5

Main Service Modules
Product Description

5

5

Features, Benefits and Functions
Eaton’s Main Service Module
●
Offering: main terminal/lug
compartment, main circuit
breaker, main fusible
switch, main bolted
pressure switch, main
fusible switch with pull
box (meets EUSERC
electrical requirements),
underground pull box
termination compartment
without cross bus (meets
EUSERC electrical
requirements)
●
Mechanically and
electrically built for use
with 1MM, 3MM, 35MM,
37MM, 35SS and 37SS
modular metering stacks
●
For integrated system
short-circuit ratings with
main devices, see series
ratings on Page V1-T5-142
●
All main service modules
include both left and right
horizontal bus closure
plates
●
Two-pole devices are
applied to single-phase,
three-wire, 120/240V or
208Y/120V systems, threepole devices to 208Y/240V
or 120/240V delta systems

●

●

●

●

Single-phase mains couple
to any modular metering
stack (1MM, 3MM, 35MM,
37MM, 35SS and 37SS)
Three-phase mains require
three-phase bussed stacks.
These modular metering
stacks are 3MM, 35MM,
37MM, 35SS and 37SS
If the ampere rating of the
main service module is
greater than the horizontal
bus rating of the meter
stack (residential or
commercial), the main
service module must be
center fed. Examples:
1200A Main Circuit Breaker
(1MCB1200R) with an
800A residential stack
(1MM512R). 1600A Main
Terminal Box
(3MTB1600R) with a
1200A residential stack
(3MM212R12)
Most main service
modules are available with
aluminum or copper bus

Main Circuit Breakers with
Busway Connections
●
Three-phase, 400–200A
main circuit breakers
●
Three-phase, 400–800A
main fusible switches
●
Simple bridge joint
connection
●
Variety of options:
●
Right or left mounting
●
Internal ground or
housing ground
●

The MFS/MCB and busway
connector are supplied
completely assembled

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-101

5.10
5

Metering Products
Group Metering

Catalog Number Selection

5

3 MTB 400 R

5

Phase
1 = Single-phase
3 = Three-phase

5
5
5
5
5

Accessories and Additional Options
BLK= Box lug kit (accessory)
CLK= Compression lug (accessory)
B = Bottom feed
T = Top feed
UG= Pull box
Blank= No options
Enclosure
R = NEMA 3R

Ampere Rating
400A
600A
800A
1000A
1200A
1400A
1600A
2000A

5
5
5

Bus Material
C = Copper bus
Blank= Aluminum bus

Type of Metering
BTB = Main terminal box
MCB = Main circuit breaker
BPS = Bolted pressure switch
MFS = Main fusible switch
UGPB = Underground pull box
MTBE = Main terminal box with utility
pull box
MCBE = Main circuit breaker with utility
pull box

5

5

C

When Ordering:
1. Determine catalog number of Main Service Module.

5

2. Determine catalog number of Meter Stack (Residential or Commercial).

5

3. Find quantity and catalog numbers for tenant circuit breakers (found on Page V1-T5-125 or V1-T5-135).
Order one breaker per socket.

5

4. If any accessories are needed, order from Pages V1-T5-136 and V1-T5-137.

5
5
5
5
5
5
5
5
5
5
5
5
5
5
V1-T5-102

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Metering Products
Group Metering

5.10

Product Selection

5

Main Terminal Box
●
Phase and neutral lugs
are included
●
Top or bottom feed:
●
For top feed, use
Myer type hub

Main Terminal Box

●
●

5

Indoor or outdoor
Terminal box UL listed
short-circuit rating is the
least AIC rating of any
installed main tenant
breaker—to a maximum
of 100,000 rms
symmetrical amperes

5
5
5
5

Main Terminal Box
System Voltage
Ampere
Rating

Line Side Lug and Wire Sizes—Included

120/208 Vac Three-Phase, Four-Wire

Catalog Number

Catalog Number

5

Use three-phase

3MTB400R

5

Aluminum Bus (Standard Offering)
(1) #6–600 or (2) 1/0–250 kcmil 2

400

3

600

(2) 250–500 kcmil

800

(4) 250–500 kcmil 45

1200

1

(4) 250–500 kcmil

56

5

120/240 Vac Single-Phase, Three-Wire

Use three-phase

3MTB600R

1MTB800R

3MTB800R

1MTB1200R

3MTB1200R

5
5

5

Aluminum Bus (EUSERC)
400

Crimp lug landing pads (no lugs included)

1MTBE400R 7

3MTBE400R 7

800

Crimp lug landing pads (no lugs included)

1MTBE800R 7

3MTBE800R 7

5
5

Copper Bus (Premium Offering)
kcmil 2

400

(1) #6–600 or (2) 1/0–250

Use three-phase

3MTB400RC

600

(2) 250–500 kcmil 3

Use three-phase

3MTB600RC

(4) 250–500 kcmil 45

1MTB800RC

3MTB800RC

(4) 250–500 kcmil 56

1MTB1200RC

3MTB1200RC

(6) 500 kcmil 8

1MTB1600RC

3MTB1600RC

800
1200

1

1600 1

Main Terminal Box Riser Panel
Eaton’s Main Terminal Box
Riser Panel is a main terminal
box with offset lugs on each
phase to allow riser cables to
pass through the main
service module.

5
5
5
5

These panels are used in the
construction of assisted living
homes, dormitories, public
housing complexes and
apartments.

5
5
5

Main Terminal Box Riser Panel
System Voltage
Ampere
Rating

Line and Load Side Lug and
Wire Sizes Included

120/240 Vac Single-Phase,
Three-Wire Catalog Number

120/208 Vac Three-Phase,
Four-Wire Catalog Number

1200

#2 AWG–750 kcmil

19

Use three-phase

3MTB1200RCRIS

1600

#2 AWG–750 kcmil 19

Use three-phase

3MTB1600RCRIS

Copper Bus (Standard Offering)

5
5
5

Notes
1 1200A main devices must be center fed when installing 800A residential meter stacks.
1600A main devices must be center fed when installing 800–1200A residential and commercial meter stacks.
2 For 400A units, to obtain (4) 750 kcmil cables per phase—order quantity 4 1MPLK2. Kit contains one lug.
3 For compression lug landing kits for 600A units, order 3MTB600CLK. Kit includes lug landings for three phases and neutral.
4 For 800A units, to obtain (4) 1/0–300 kcmil or (2) 1/0–750 kcmil cables per phase—order catalog number 3MTB800BLK,
one lug kit per main terminal box ordered (neutral and ground included in kit).
5 For 800A and 1200A units, for compression lug landing kits, order 3MTB1200CLK. Kit includes lug landings for three-phase and neutral.
6 For 1200A units, to obtain (6) 1/0–300 kcmil or (3) 750 kcmil cables per phase—order catalog number 3MTB1200BLK,
one lug kit per main terminal box ordered (neutral and ground included in kit).
7 Meets EUSERC electrical requirements and eliminates the need to add additional pull box section.
8 For 1600A units, to obtain (4) 750 kcmil cables per phase—order catalog number 3MTB1600BLK, one lug kit per main terminal box ordered.
For a 1600A compression lug landing kit, order catalog number 3MTB1600CLK.
9 Quantity (10) lugs per phase—quantity (5) lugs incoming and quantity (5) lugs outgoing per phase.
Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

5

5
5
5
5
5
V1-T5-103

5.10
5
5
5
5
5

Metering Products
Group Metering

Main Circuit Breaker
●
Phase and neutral lugs
included. If additional
neutral lugs are needed,
order 1MCB1200NLK
for (3) 1/0–750 or
(6) 1/0–300 kcmil
●
For shunt trip mains, order
the field-installable shunt
trip kit in this volume,
Tab 1, section 1.1

●

●

For overhead feed, use
Myer type hub. Verify local
utility approval
For compression lugs on
400, 600, 800, 1000 and
1200A units, add CL to the
end of the part number
(includes copper lug pads
for lines and neutral)

●

●

1200A or greater main
devices must be center
fed when installing 800A
residential meter stacks
1400, 1600 and 2000A
main devices must be
center fed when installing
800 and 1200A residential
and commercial meter
stacks

5
5

Main Circuit Breaker

5

Main Circuit Breaker
Main
Ampere
Rating

5

Main
Circuit
Breaker
Type

System Voltage

Feed

kAIC

Line Side Lug and Wire Sizes
(Lugs Included with Main Breaker) 1

120/240 Vac
120/208 Vac
Single-Phase, Three-Wire Three-Phase, Four-Wire
Catalog Number

Catalog Number

Aluminum Bus (Standard Offering)

5

250

KD

Bottom/top

65

(2) 3/0–250 kcmil or (1) 2/0–500 kcmil

1MCB250R

3MCB250R

250

HKD

Bottom/top

100

(2) 3/0–250 kcmil or (1) 2/0–500 kcmil

1MHCB250R

3MHCB250R

5

300

KD

Bottom/top

65

(2) 3/0–250 kcmil or (1) 2/0–500 kcmil

1MCB300R

3MCB300R

300

HKD

Bottom/top

100

(2) 3/0–250 kcmil or (1) 2/0–500 kcmil

1MHCB300R

3MHCB300R

5

350

KD

Bottom/top

65

(2) 3/0–250 kcmil or (1) 2/0–500 kcmil

1MCB350R

3MCB350R

350

HKD

Bottom/top

100

(2) 3/0–250 kcmil or (1) 2/0–500 kcmil

1MHCB350R

3MHCB350R

5

400

KD

Bottom/top

65

(2) 3/0–250 kcmil or (1) 2/0–500 kcmil

1MCB400R 2

400

HKD

Bottom/top

100

(2) 3/0–250 kcmil or (1) 2/0–500 kcmil

1MHCB400R

5

500

LD

Bottom/top

65

(2) 400–500 kcmil

1MCB500R

3MCB500R

5

500

HLD

Bottom/top

100

(2) 400–500 kcmil

1MHCB500R

3MHCB500R

600

LD

Bottom/top

65

(2) 400–500 kcmil

1MCB600R 2

3MCB600R 2

600

HLD

Bottom/top

100

(2) 400–500 kcmil

1MHCB600R 2

3MHCB600R 2

700

HMDL

Bottom/top

100

(3) 3/0–400 kcmil

1MHCB700R

3MHCB700R

700

MDL

Bottom/top

65

(3) 3/0–400 kcmil

1MCB700R

3MCB700R
3MCB800R 2

5
5

2

3MCB400R 2
3MHCB400R 2

800

MDL

Bottom/top

65

(3) 3/0–400 kcmil

1MCB800R 2

5

800

MDL

Bottom/top

65

(2) 500–750 kcmil

1MCB800R750

3MCB800R750

800

HMDL

Bottom/top

100

(3) 3/0–400 kcmil

1MHCB800R 2

3MHCB800R 2

5

900

NGS

Bottom/top

65

(4) 4/0–500 kcmil 3

1MCB900R 4

3MCB900R 4

900

NGH

Bottom/top

100

(4) 4/0–500

kcmil 3
kcmil 3

1MHCB900R

4

3MHCB900R 4

1MCB1000R

24

3MCB1000R 24

5

1000

NGS

Bottom/top

65

(4) 4/0–500

1000

NGS

Bottom/top

65

(2) 500–750 kcmil

1MCB1000R750

3MCB1000R750

5

1000

NGH

Bottom/top

100

(4) 4/0–500 kcmil 3

1MHCB1000R 24

3MHCB1000R 24

1200

NGS

Bottom

65

(4) 4/0–500 kcmil 3

1MCB1200R 24

3MCB1200R 24

5

1200

NGH

Bottom

100

(4) 4/0–500 kcmil 3

1MHCB1200R 24

3MHCB1200R 24

1200

NGS

Bottom

65

(2) 500–750 kcmil

Use three-phase

3MCB1200R750

5

Notes
1 If additional neutral lugs are needed, order 1MCB1200NLK [(3) 1/0–750 kcmil or (6) 1/0–300 kcmil].
2 Add CL to end of catalog number for compression lug pads (includes lug pads for lines and neutral).
3 If (3) 500–750 kcmil are needed, order TA1201NB1. Order one kit per pole.
4 Main devices with a rating greater than 800A can be used with 800A residential modular stacks, but only as a center fed main.

5
5
5
5
5
5
5
V1-T5-104

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

5.10

Metering Products
Group Metering

Main Circuit Breaker

Main Circuit Breaker

5
5

Main Circuit Breaker, continued
Main
Ampere
Rating

System Voltage

Main
Circuit
Breaker
Type

Feed

kAIC

Line Side Lug and Wire Sizes
(Lugs Included with Main Breaker) 1

120/240 Vac
120/208 Vac
Single-Phase, Three-Wire Three-Phase, Four-Wire
Catalog Number

Catalog Number

Aluminum Bus (EUSERC)
300

KD

Bottom/top

65

Crimp lug landing pads (no lugs included)

1MCBE300R

3MCBE300R

350

KD

Bottom/top

65

Crimp lug landing pads (no lugs included)

1MCBE350R

3MCBE350R

400

KD

Bottom/top

65

Crimp lug landing pads (no lugs included)

1MCBE400R

3MCBE400R

400

HKD

Bottom/top

100

Crimp lug landing pads (no lugs included)

1MHCBE400R

3MHCBE400R

500

LD

Bottom/top

65

Crimp lug landing pads (no lugs included)

1MCBE500R

3MCBE500R

600

LD

Bottom/top

65

Crimp lug landing pads (no lugs included)

1MCBE600R

3MCBE600R

600

HLD

Bottom/top

100

Crimp lug landing pads (no lugs included)

1MHCBE600R

3MHCBE600R

800

MDL

Bottom/top

65

Crimp lug landing pads (no lugs included)

1MCBE800R

3MCBE800R

5
5
5
5
5
5
5
5

800

HMDL

Bottom/top

100

Crimp lug landing pads (no lugs included)

1MHCBE800R

3MHCBE800R

1000

NGS

Bottom/top

65

Crimp lug landing pads (no lugs included)

1MCBE1000R

3MCBE1000R

1200

NGS

Bottom

65

Crimp lug landing pads (no lugs included)

1MCBE1200R

3MCBE1200R

1200

NGH

Bottom

100

Crimp lug landing pads (no lugs included)

1MHCBE1200R

3MHCBE1200R

5
5

5

Copper Bus (Premium Offering)
400

KD

Bottom/top

65

(2) 3/0–250 kcmil or (1) 2/0-500 kcmil

1MCB400RC 2

3MCB400RC 2

400

HKD

Bottom/top

100

2/0–500 kcmil

1MHCB400RC 2

3MHCB400RC 2

600

LD

Bottom/top

65

(2) 300–500 kcmil

1MCB600RC 2

3MCB600RC 2

2

600

HLD

Bottom/top

100

(2) 300–500 kcmil

1MHCB600RC

800

MDL

Bottom/top

65

(3) 3/0–400 kcmil

1MCB800RC 2

5

3MHCB600RC 2

5

3MCB800RC 2

2

3MHCB800RC 2

800

HMDL

Bottom/top

100

(3) 3/0–400 kcmil

1MHCB800RC

900

NGS

Bottom/top

65

(4) 4/0–500 kcmil 3

1MCB900RC 4

3MCB900RC 4

900

NGH

Bottom/top

100

(4) 4/0–500 kcmil 3

1MHCB900RC 4

3MHCB900RC 4

1000

NGS

Bottom/top

65

(2) 500–750 kcmil

1MCB1000R750C

3MCB1000R750C

1000

NGS

Bottom/top

65

(4) 4/0–500 kcmil 3

1MCB1000RC 24

3MCB1000RC 24

1000

NGH

Bottom/top

100

(4) 4/0–500 kcmil 3

1MHCB1000RC 24

3MHCB1000RC 24

1200

NGS

Bottom

65

(2) 500–750 kcmil

Use three-phase

3MCB1200R750C

kcmil 3

1200

NGS

Bottom

65

(4) 4/0–500

1200

NGH

Bottom

100

(4) 4/0–500 kcmil 3

1MCB1200RC

24

3MCB1200RC

5
5

24

1MHCB1200RC 24

3MHCB1200RC 24

46

46

kcmil 5

1MCB1400RBC

1400

RGH

Bottom

100

(4) 500–1000

1400

RGH

Top

100

(4) 500–1000 kcmil 5

1MCB1400RT 7

3MCB1400RBC

3MCB1400RT 7

1600

RGH

Bottom

100

(4) 500–1000 kcmil 5

1MCB1600RBC 67

3MCB1600RBC 67

1600

RGH

Top

100

(4) 500–1000 kcmil 5

1MCB1600RT 7

3MCB1600RT 7

2000

RGH

Bottom

100

(6) #2–600 kcmil

1MCB2000RBC 68

3MCB2000RBC 68

2000

RGH

Top

100

(6) #2–600 kcmil

1MCB2000RT 8

3MCB2000RT 8

Bottom

100

Crimp lug landing pads (no lugs included)

1MCBE1000RC

3MCBE1000RC

NGH

1200

NGS

Bottom

65

Crimp lug landing pads (no lugs included)

1MCBE1200RC

3MCBE1200RC

1200

NGH

Bottom

100

Crimp lug landing pads (no lugs included)

1MHCBE1200RC

3MHCBE1200RC

5
5
5
5
5
5

Notes
1 If additional neutral lugs are needed, order 1MCB1200NLK [(3) 1/0–750 kcmil or (6) 1/0–300 kcmil].
2 Add CL to end of catalog number for compression lug pads (includes lug pads for lines and neutral).
3 If (3) 500–750 kcmil are needed, order TA1201NB1. Order one kit per pole.
4 Main devices with a rating greater than 800A can be used with 800A residential modular stacks but only as a center fed main.
5 If (6) #2–600 kcmil lugs are needed, order TA2000RD. Catalog number includes terminals and hardware for three poles. If neutral is needed, order TA2000N.
6 Copper bus.
7 Main devices with a rating greater than 1200A can be used with residential and commercial modular metering stacks but only as a center fed main.
8 Only to be used in center feed applications with 1200A meter stacks. Not to be used with 800A stacks.

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

5

5

Copper Bus (EUSERC)
1000

5

5
5
5
5
V1-T5-105

5.10

Metering Products
Group Metering

5

Main Fusible Switches
●
Fuses not included
●
Main lugs and neutral
included with device
●
100 kAIC rating on
switches with Class T
fuses installed. If
converting to Class H, the
kAIC rating is 10 and if
converted to Class R, the
kAIC rating is 200

5

Note: This is the fuse rating,
switch still rated at 100 kAIC.

5
5
5
5

●

●

800A top and bottom fed
units are supplied with
Class T fuse clips as
standard. The Class T fuse
clips are field convertible to
Class L by repositioning.
No kit is needed
Barrier kits available
for 400A–800A
fusible switches:
Bottom feed—3MFSBBK,
Top feed—3MFSTBK

5
5

Main Fusible Switches

Main Fusible Switches
System Voltage

5

Class Fuse
Clips (Fuses
Not Included)

5

Ampere
Rating

5

Aluminum Bus (Standard Offering)
400

5

Feed

Bottom

Line Side Box Lugs and Wire Sizes
(Included with Switch)

120/240 Vac
Single-Phase,
Three-Wire

120/208 Vac
Three-Phase,
Four-Wire

Catalog Number

Catalog Number

T1

(2) 1/0–300 kcmil or (1) 750 kcmil 45

1MFS400RB

3MFS400RB

1

(2) 1/0–300 kcmil or (1) 750 kcmil 56

1MFS400RT

3MFS400RT

400

Top

T

600

Bottom

T2

(2) #2–600 kcmil 45

1MFS600RB

3MFS600RB

5

600

Top

T2

(2) #2–600 kcmil 56

1MFS600RT

3MFS600RT

5

800

Bottom

T, L 3

(4) 3/0–750 kcmil 4

1MFS800RB

3MFS800RB

800

Top

T, L 3

(4) 3/0–750 kcmil 6

1MFS800RT

3MFS800RT

1MFS1200RB

3MFS1200RB

3MFS400RBC

5

1200

5

400

Bottom

T, L

3

(4) #2–600 kcmil

7

Copper Bus (Premium Offering)
Bottom

T1

(2) 1/0–300 kcmil or (1) 750 kcmil 45

1MFS400RBC

1

(2) 1/0–300 kcmil or (1) 750 kcmil 56

1MFS400RTC

3MFS400RTC
3MFS600RBC

400

Top

T

600

Bottom

T2

(2) #2–600 kcmil 45

1MFS600RBC

5

600

Top

T2

(2) #2–600 kcmil 56

1MFS600RTC

3MFS600RTC

800

Bottom

T, L 3

(4) 3/0–750 kcmil 4

1MFS800RBC

3MFS800RBC

5

800

Top

T, L 3

(4) 3/0–750 kcmil 6

1MFS800RTC

3MFS800RTC

1MFS1200RBC

3MFS1200RBC

5

1200

5

Bottom

T, L

3

(4) #2–600 kcmil

7

Notes
1 If Class H fuse clips are needed, use catalog number WCG3HK400 (order (1) per phase).
If Class R fuse clips are needed, order catalog number DS56FK in addition to WCG3HK400.
In order to go from T to R, the device must first be converted to H.
All kits are field installable and each DS56FK kit will convert three poles.
2 If Class H fuse clips are needed, use catalog number WCG3HK600 (order (1) per phase).
If Class R fuse clips are needed, order catalog number DS66FK in addition to WCG3HK600.
In order to go from T to R, the device must first be converted to H.
All kits are field installable and each DS66FK kit will convert three poles.
3 Class T fuse clips provided are field convertible to Class L by repositioning. No kit is needed.
4 If compression lugs are being used, order 3MFS800CLK. This compression lug kit includes four pads (three poles and neutral).
5 1MFS600BLK (4) 3/0–750 kcmil/phase (one kit/phase and one kit/neutral).
6 If compression lugs are being used, order 3MFS800CLKT. This compression lug kit includes four pads (three poles and neutral).
7 IMFS1200LK (3) 750 kcmil/phase (one kit/phase). IMFS1200LKN (3) 750 kcmil (neutral).

5
5
5
5
5
5
5
5
5
5
V1-T5-106

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

5.10

Metering Products
Group Metering

Main Fusible Switch with
Utility Pull Box
●
Fuses not included
●
Includes lug landing pads
on line side and neutral
●
Spacer kit 3MMBSK
required when stacks are
mounted on right-hand
side in EUSERC areas
●
100 kAIC rating on
switches with Class T
fuse clips installed

Main Fusible Switch
with Utility Pull Box

5
5
5
5
5
5
5

Main Fusible Switch with Utility Pull Box
System Voltage
Ampere
Rating

Feed

Class Fuse Clips
(Fuses Not Included)

Line Side Box Lugs
and Wire Sizes
(Included with Switch)

120/240 Vac
Single-Phase, Three-Wire

120/208 Vac
Three-Phase, Four-Wire

Catalog Number

Catalog Number

5
5
5

Aluminum Bus (Standard Offering)
400

Bottom

T

1

1MFS400RUG

3MFS400RUG

600

Bottom

T

1

1MFS600RUG

3MFS600RUG

800

Bottom

T, L

1

1MFS800RUG

3MFS800RUG

1200

Bottom

T

1

1MFS1200RUG

3MFS1200RUG

5
5

5

Copper Bus (Premium Offering)
400

Bottom

T

1

1MFS400RUGC

3MFS400RUGC

600

Bottom

T

1

1MFS600RUGC

3MFS600RUGC

1MFS800RUGC

3MFS800RUGC

1MFS1200RUGC

3MFS1200RUGC

800

Bottom

T, L

1

1200

Bottom

T

1

5
5
5

Utility Pull Box
●
Includes lug landing pads
on line side and neutral
●
Requires cable connection
in field to main device;
does not include horizontal
cross bus

5
5
5
5
5

Pull Box
System Voltage
Ampere
Rating

Feed

Line Side
Lug Information

120/240 Vac
Single-Phase, Three-Wire

120/208 Vac
Three-Phase, Four-Wire

Catalog Number

Catalog Number

5
5

Aluminum Bus (Standard Offering)
Bottom

1

1/0–750 kcmil or (2) 1/0–300 kcmil

1UGPB400R

3UGPB400R

800

Bottom

1

(2) 1/0–750 kcmil or (4) 1/0–300 kcmil

1UGPB800R

3UGPB800R

1200

Bottom

1

(4) #2–600 kcmil

1UGPB1200R

3UGPB1200R

3UGPB400RC

400

5
5

Copper Bus (Premium Offering)
Bottom

1

1/0–750 kcmil or (2) 1/0–300 kcmil

1UGPB400RC

800

Bottom

1

(2) 1/0–750 kcmil or (4) 1/0–300 kcmil

1UGPB800RC

3UGPB800RC

1200

Bottom

1

(4) #2–600 kcmil

1UGPB1200RC

3UGPB1200RC

400

5

Load Side Lug Information
for Cable Connection
to Main Disconnect

5
5

Note
1 Pull box section includes landing studs for line side compression lugs. Wire sizes refer to load side connection.

5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-107

5.10
5
5
5
5
5
5
5
5

Metering Products
Group Metering

Main Bolted Pressure
Contact Switches
●
Add suffix ST to catalog
number for shunt trip
●
Fuses not included
●
100 kAIC rating on
switches with Class L
fuses installed

Main Bolted Pressure Contact Switches
System Voltage
Ampere
Rating

Feed

120/240 Vac
Single-Phase, Three-Wire
Class Fuse Clips
(Fuses Not Included) Catalog Number

120/208 Vac
Three-Phase, Four-Wire
Catalog Number

Line Side Box Lugs
and Wire Sizes
(Included)

Copper Bus

5

1200

Bottom

L

1BPS1200RB

3BPS1200RB

(4) #4–600 kcmil

1200

Top

L

1BPS1200RT

3BPS1200RT

(4) #4–600 kcmil

5

1600

Bottom

L

Use three-phase

3BPS1600RB

(6) #4–600 kcmil

1600

Top

L

Use three-phase

3BPS1600RT

(6) #4–600 kcmil

2000

Bottom

L

Use three-phase

3BPS2000RB

(8) #4–600 kcmil

2000

Top

L

Use three-phase

3BPS2000RT

(8) #4–600 kcmil

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

V1-T5-108

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Metering Products
Group Metering

Main Circuit Breaker with Busway Connection
Verify proper left/right–bus/main phasing.
Note: “Right” means that the bus duct is to the right of the main and
“left” means that the bus duct is to the left of the main. (See Dimension/
Layout section for clarification.)

Feed

400

Bottom

600

Bottom

800

Bottom

400

Bottom

600

Bottom

800

Bottom

400

Bottom

600

Bottom

800

Bottom

400

Bottom

600

Bottom

800

Bottom

400

Bottom

600

Bottom

800

Bottom

400

Bottom

600

Bottom

800

Bottom

400

Bottom

600

Bottom

800

Bottom

400

Bottom

600

Bottom

800

Bottom

400

Bottom

400

Bottom

600

Bottom

600

Bottom

800

Bottom

800

Bottom

1000

Bottom

1000

Bottom

1200

Bottom

1200

Bottom

400

Bottom

400

Bottom

600

Bottom

600

Bottom

800

Bottom

800

Bottom

1000

Bottom

1000

Bottom

1200

Bottom

1200

Bottom

400

Bottom

400

Bottom

System Voltage
120/208 Vac
Three-Phase, Four-Wire
Catalog Number

Internal
Ground or
Housing
Ground

Standard T
or TO
Right
Opposite
or Left
Phasing
Side

Ampere
Rating

Feed

3MFS400BCRGTO
3MFS600BCRGTO
3MFS800BCRGTO
3MFS400BCLGTO
3MFS600BCLGTO
3MFS800BCLGTO
3MFS400BCRGT
3MFS600BCRGT
3MFS800BCRGT
3MFS400BCLGT

Internal

TO

Right

1200

Bottom

Internal

TO

Right

1200

Bottom

Internal

TO

Right

400

Bottom

Internal

TO

Left

400

Bottom

Internal

TO

Left

600

Bottom

Internal

TO

Left

600

Bottom

Internal

T

Right

800

Bottom

Internal

T

Right

800

Bottom

Internal

T

Right

1000

Bottom

Internal

T

Left

1000

Bottom

3MFS600BCLGT
3MFS800BCLGT
3MFS400BCRNTO

Internal

T

Left

1200

Bottom

Internal

T

Left

1200

Bottom

Housing

TO

Right

400

Bottom

3MFS600BCRNTO
3MFS800BCRNTO
3MFS400BCLNTO
3MFS600BCLNTO
3MFS800BCLNTO
3MFS400BCRNT
3MFS600BCRNT
3MFS800BCRNT
3MFS400BCLNT
3MFS600BCLNT
3MFS800BCLNT
3MCB400BCRGT

Housing

TO

Right

400

Bottom

Housing

TO

Right

600

Bottom

Housing

TO

Left

600

Bottom

Housing

TO

Left

800

Bottom

Left

800

Bottom

T

Right

1000

Bottom

Housing

T

Right

1000

Bottom

Housing

T

Right

1200

Bottom
Bottom

Housing

T

Left

1200

Housing

T

Left

400

Bottom
Bottom

T

Left

Internal

T

Right

600

Bottom

3HMCB400BCRGT
3MCB600BCRGT
3HMCB600BCRGT

Internal

T

Right

600

Bottom

Internal

T

Right

800

Bottom

Internal

T

Right

800

Bottom

Internal

T

Right

1000

Bottom

Internal

T

Right

1000

Bottom

Internal

T

Right

1200

Bottom

Internal

T

Right

1200

Bottom

Internal

T

Right

400

Bottom

Internal

T

Right

400

Bottom

Internal

T

Left

600

Bottom

Internal

T

Left

600

Bottom

Internal

T

Left

800

Bottom

Internal

T

Left

800

Bottom

Internal

T

Left

1000

Bottom

Internal

T

Left

1000

Bottom

Internal

T

Left

1200

Bottom

Internal

T

Left

1200

Bottom

Internal

T

Left

400

Bottom

Internal

T

Left

400

Bottom

Housing

T

Right

600

Bottom

Housing

T

Right

600

Bottom
Bottom

Bottom

800

Bottom

1000

Bottom

1000

Bottom

3HMBC1000BCRNT

Bottom

TO

Housing

Housing

800

Bottom

600

Housing

400

3MCB800BCRGT
3HMCB800BCRGT
3MCB1000BCRGT
3HMCB1000BCRGT
3MCB1200BCRGT
3HMCB1200BCRGT
3MCB400BCLGT
3HMCB400BCLGT
3MCB600BCLGT
3HMCB600BCLGT
3MCB800BCLGT
3HMCB800BCLGT
3MCB1000BCLGT
3HMCB1000BCLGT
3MCB1200BCLGT
3HMCB1200BCLGT
3MCB400BCRNT
3HMCB400BCRNT
3MCB600BCRNT
3HMCB600BCRNT
3MCB800BCRNT
3HMCB800BCRNT
3MBC1000BCRNT

600

Using this information, select the correct main device catalog
number per the selection chart.

Main Circuit Breaker with Busway Connection, continued

Main Circuit Breaker with Busway Connection

Ampere
Rating

5.10

Housing

T

Right

800

Housing

T

Right

800

Bottom
Bottom

Housing

T

Right

1000

Housing

T

Right

1000

Bottom

Housing

T

Right

1200

Bottom

Housing

T

Right

1200

Bottom

System Voltage
120/208 Vac
Three-Phase, Four-Wire
Catalog Number

Internal
Ground or
Housing
Ground

Standard T
or TO
Right
Opposite
or Left
Phasing
Side

3MCB1200BCRNT
3HMCB1200BCRNT
3MCB400BCLNT
3HMCB400BCLNT
3MCB600BCLNT
3HMCB600BCLNT
3MCB800BCLNT

Housing

T

Right

Housing

T

Right

Housing

T

Left

Housing

T

Left

Housing

T

Left

Housing

T

Left

Housing

T

Left

3HMCB800BCLNT
3MCB1000BCLNT
3HMCB1000BCLNT
3MCB1200BCLNT
3HMCB1200BCLNT
3MCB400BCRGTO

Housing

T

Left

Housing

T

Left

Housing

T

Left

Housing

T

Left

Housing

T

Left

Internal

TO

Right

3HMCB400BCRGTO
3MCB600BCRGTO
3HMCB600BCRGTO

Internal

TO

Right

Internal

TO

Right

Internal

TO

Right

3MCB800BCRGTO
3HMCB800BCRGTO
3MCB1000BCRGTO
3HMCB1000BCRGTO
3MCB1200BCRGTO
3HMCB1200BCRGTO
3MCB400BCLGTO
3HMCB400BCLGTO
3MCB600BCLGTO
3HMCB600BCLGTO
3MCB800BCLGTO
3HMCB800BCLGTO

Internal

TO

Right

Internal

TO

Right

Internal

TO

Right

Internal

TO

Right

Internal

TO

Right

Internal

TO

Right

Internal

TO

Left

Internal

TO

Left

Internal

TO

Left

Internal

TO

Left

Internal

TO

Left

Internal

TO

Left

3MCB1000BCLGTO
3HMCB1000BCLGTO
3MCB1200BCLGTO
3HMCB1200BCLGTO
3MCB400BCRNTO
3HMCB400BCRNTO
3MCB600BCRNTO
3HMCB600BCRNTO
3MCB800BCRNTO
3HMCB800BCRNTO
3MCB1000BCRNTO
3HMCB1000BCRNTO
3MCB1200BCRNTO
3HMCB1200BCRNTO
3MCB400BCLNTO
3HMCB400BCLNTO
3MCB600BCLNTO
3HMCB600BCLNTO
3HMCB800BCLNTO
3HMCB800BCLNTO
3MCB1000BCLNTO
3HMCB1000BCLNTO
3MCB1200BCLNTO
3HMCB1200BCLNTO

Internal

TO

Left

Internal

TO

Left

Internal

TO

Left

Internal

TO

Left

Housing

TO

Right

Housing

TO

Right

Housing

TO

Right

Housing

TO

Right

Housing

TO

Right

Housing

TO

Right

Housing

TO

Right

Housing

TO

Right

Housing

TO

Right

Housing

TO

Right

Housing

TO

Left

Housing

TO

Left

Housing

TO

Left

Housing

TO

Left

Housing

TO

Left

Housing

TO

Left

Housing

TO

Left

Housing

TO

Left

Housing

TO

Left

Housing

TO

Left

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-109

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

5.10
5
5

Metering Products
Group Metering

Dimensions
Approximate Dimensions in Inches (mm)
Dimensions (Not to be Used for Construction Purposes)

5

Center Line of
Wall Mounting
Bracket

Knockouts in Bottom Endwalls Except No
KOs for Top Feed Switch or Bolted Pressure
Switch Conduit Diameter

Width

Height

Depth

Mounting

A

B

C

D

E

F

Inches

mm

400 and 600A

13.50 (342.9)

48.75 (1238.3)

7.00 (177.8)

—

54.00 (1371.6)

30.63 (777.9)

(1) 2.50, 3.00, 3.50, 4.00
(1) 0.50

(1) 63.5, 76.2, 88.9, 101.6
(1) 12.7

1

800 and 1200A

20.00 (508.0)

47.63 (1209.8)

11.75 (298.5)

12.00 (304.8)

51.50 (1308.1)

30.63 (777.9)

(2) 12.1, 19.1, 25.4
(4) 50.8, 63.5, 76.2, 88.9, 101.6

2

5

(2) 0.50, 0.75, 1.00
(4) 2.00, 2.50, 3.00, 3.50, 4.00

1600A

32.88 (835.2)

60.13 (1527.3)

11.44 (290.6)

16.00 (406.4)

64.13 (1628.9)

38.59 (980.2)

(1) 19.1, 25.4, 31.8, 38.1
(5) 76.2, 88.9, 101.6, 127.0

3

5

(1) 0.75, 1.00, 1.25, 1.50
(5) 3.00, 3.50, 4.00, 5.00

Main Circuit Breaker with Box Lugs

5
5
5

5
5
5
5
5
5
5
5
5
5
5

Main Device

KO
Dwg.

Terminal Box

400–1200A

20.00 (508.0)

47.63 (1209.8)

11.75 (298.5)

12.00 (304.8)

51.50 (1308.1)

30.63 (777.9)

(2) 0.50, 0.75, 1.00
(4) 2.00, 2.50, 3.00,3.50, 4.00

(2) 12.7, 19.1, 25.4
(4) 50.8, 63.5, 76.2, 88.9, 101.6

2

1400–2000A

24.88 (632.0)

57.13 (1451.0)

14.88 (378.0)

16.00 (406.4)

57.13 (1451.0)

44.00 (1117.6)

—

—

—

Main Circuit Breaker with Compression Lugs
400–1200A

20.00 (508.0)

61.00 (1549.4)

11.75 (298.5)

12.00 (304.8)

65.00 (1651.0)

44.00 (1117.6)

(2) 0.50, 0.75, 1.00
(4) 2.00, 2.50, 3.00, 3.50, 4.00

(2) 12.7, 19.1, 25.4
(4) 50.8, 63.5, 76.2, 88.9, 101.60

2

Main Fusible Switch
Bottom feed
400–800A

20.00 (508.0)

47.63 (1209.8)

11.75 (298.5)

12.00 (304.8)

51.50 (1308.1)

30.63 (777.9)

(2) 0.50, 0.75, 1.00
(4) 2.00, 2.50, 3.00, 3.50, 4.00

(2) 12.7, 19.1, 25.4
(4) 50.8, 63.5, 76.2, 88.9, 101.6

2

Top feed
400–800A

20.00 (508.0)

47.63 (1209.8)

11.75 (298.5)

12.00 (304.8)

51.50 (1308.1)

18.13 (460.4)

(2) 0.50, 0.75, 1.00
(4) 2.00, 2.50, 3.00, 3.50, 4.00

(2) 12.7, 19.1, 25.4
(4) 50.8, 63.5, 76.2, 88.9, 101.6

2

1200A

33.50 (850.9)

52.75 (1339.9)

11.88 (301.8)

16.00 (406.4)

56.25 (1428.8)

30.75 (781.1)

(5) 3.50, 4.00, 5.00
(1) 0.75, 1.00, 1.25, 1.50

(5) 88.9, 101.6, 127.0
(1) 19.1, 25.4, 31.8, 38.1

4

66.50 (1689.1)

19.50 (495.3)

28.00 (711.2)

60.00 (1524.0)

30.63 (777.9)

—

—

—

Bolted Pressure Switch
36.50 (927.1)

Main Fusible Switch with Pull Box
400A

20.00 (508.0)

61.00 (1549.4)

11.75 (298.5)

12.00 (304.8)

65.00 (1651.0)

44.00 (1117.6)

(2) 0.50, 0.75, 1.00
(4) 2.00, 2.50, 3.00, 3.50, 4.00

(2) 12.7, 19.1, 25.4
(4) 50.8, 63.5, 76.2, 88.9, 101.6

2

600 and 800A
(single-phase)

20.00 (508.0)

61.00 (1549.4)

11.75 (298.5)

12.00 (304.8)

65.00 (1651.0)

44.00 (1117.6)

(2) 0.50, 0.75, 1.00
(4) 2.00, 2.50, 3.00, 3.50, 4.00

(2) 12.7, 19.1, 25.4
(4) 50.8, 63.5, 76.2, 88.9, 101.6

2

600 and 800A
(three-phase)

25.06 (636.5)

61.00 (1549.4)

11.75 (298.5)

17.00 (431.8)

65.00 (1651.0)

44.00 (1117.6)

(2) 0.50, 0.75, 1.00
(4) 2.00, 2.50, 3.00, 3.50, 4.00

(2) 12.7, 19.1, 25.4
(4) 50.8, 63.5, 76.2, 88.9, 101.6

4

1200A

33.50 (850.9)

61.50 (1562.1)

11.88 (301.8)

16.00 (406.4)

65.25 (1657.4)

48.00 (1219.2)

(5) 3.50, 4.00, 5.00
(1) 0.75, 1.00, 1.25, 1.50

(5) 88.9, 101.6, 127.0
(1) 19.1, 25.4, 31.8, 38.1

4

5

Main Circuit Breaker with Pull Box (EUSERC)

5

400A

20.01 (508.2)

60.44 (1535.2)

11.14 (283.0)

12.00 (304.8)

65.11 (1653.8)

39.75 (1009.6)

(4) 2.50, 3.00, 3.50, 4.00

(4) 63.5, 76.2, 88.9, 101.6

2

800A

24.88 (632.0)

60.94 (1547.9)

11.14 (283.0)

17.00 (431.8)

64.88 (1648.0)

39.81 (1011.2)

(4) 2.50, 3.00, 3.50, 4.00

(4) 63.5, 76.2, 88.9, 101.6

2

1200A

33.00 (838.2)

61.14 (1553.0)

11.32 (287.5)

16.00 (406.4)

65.25 (1657.4)

43.56 (1106.4)

(4) 2.50, 3.00, 3.50, 4.00

(4) 63.5, 76.2, 88.9, 101.6

4

5
5
5
5
5
5
5
5
5

Pull Box
400A

16.38 (416.1)

44.88 (1140.0)

7.88 (200.2)

8.00 (203.2)

45.75 (1162.1)

28.63 (727.2)

(2) 4.00

101.6

5

800A

24.38 (619.3)

46.88 (1190.8)

11.88 (301.8)

12.00 (304.8)

47.75 (1212.9)

32.25 (819.2)

(3) 4.00

101.6

6

1200A

32.50 (825.5)

56.88 (1444.8)

12.00 (304.8)

17.75 (450.9)

57.75 (1466.9)

42.25 (1073.2)

(4) 5.00

127.0

7

EUSERC Bussed Pull Section
Single-phase
400 and 800A

20.13 (511.3)

61.00 (1549.4)

11.25 (285.8)

12.00 (304.8)

64.88 (1648.0)

44.00 (1117.6)

(4) 2.50, 3.00, 3.50, 4.00

(4) 63.5, 76.2, 88.9, 101.6

5

Three-phase
400 and 800A

25.13 (638.3)

61.00 (1549.4)

11.88 (301.8)

17.00 (431.8)

64.88 (1648.0)

44.00 (1117.6)

(4) 2.50, 3.00, 3.50, 4.00

(4) 63.5, 76.2, 88.9, 101.6

6

EUSERC Main Terminal Box
Single-phase
400 and 800A

20.13 (511.3)

61.00 (1549.4)

11.88 (301.8)

12.00 (304.8)

64.88 (1648.0)

44.00 (1117.6)

(2) 0.50, 0.75, 1.00

(2) 12.7, 19.1, 25.4

2

Three-phase
400A

20.13 (511.3)

61.00 (1549.4)

11.88 (301.8)

12.00 (304.8)

64.88 (1648.0)

44.00 (1117.6)

(4) 2.00, 2.50, 3.00, 3.50, 4.00

(4) 50.8, 63.5, 76.2, 88.9, 101.6

2

Three-phase
800A

25.13 (638.3)

61.00 (1549.4)

11.88 (301.8)

17.00 (431.8)

64.88 (1648.0)

44.00 (1117.6)

(4) 2.00, 2.50, 3.00, 3.50, 4.00

(4) 50.8, 63.5, 76.2, 88.9, 101.6

2

V1-T5-110

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

5.10

Metering Products
Group Metering

Approximate Dimensions in Inches (mm)
Main Circuit Breakers, Terminal Boxes and Pull Boxes

5

Bolted Pressure Switch

A

A

5

C

5
5
E

5

B
E

5

B

F
F

5
5

C

D

Top Feed Fusible Switch

5

EUSERC Main Terminal Box
C

A

5

25.00
(635.0)

D

Main CB, Non-Euserc Terminal Box and Pullboxes

A

5

C

5
5
E

5

B

B

5
5

F

5
5

17.00
(431.8)
Top Feed Switch (No Knockouts)
D

5

Bottom Feed Fusible Switch and Combination Fusible
Switch with Pull Box

5
5

C

A

5
5
E

5

B

5

F

5
5

17.00
(431.8)
Bottom Feed Switch and Combination Switch/Pullbox
D

5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-111

5.10
5
5
5
5
5

Group Metering

Approximate Dimensions in Inches (mm)
Knockout 5

Knockout 1
.625
.010
.080
.020

5.375
.010

3.500
.010

6.850
.020

KO (10)
KO (10)

7.000
+.000
–.030

3.000
.020

Stamped
ID Mark

.200
.020
Typ.

.780 .020 Typ.

12.375 .010
.175
.010

+.003
.169 –.000 Diameter 5 Hole

Knockout 6

Knockout 2
.45

22.54
11.62

.61

.250
Ref.

3.75

10.38

2.50

5

5

6.120
.020

CL

.438
.010

5

5

2.880
.030 3.010
.010

.150 .020
Typ.

.875
.020

5

5

3.250
.020

KO (44)

5
5

.150 .020 Typ.

.080
.020

2.880
.010

.800
.030

6.000
.020

5.000
.020

2-1/2”, 3”, 3-1/2”, 4” KO
1 Knockout Required
.310 .030 Diameter
2.500
Paint Hole
.020

1/2”Knockout
1 Required
Per 50-1827-1

KO (1)

6.500 Outside .010

5

Metering Products

.150 .020
Typ.

1.93
4.250 .150
.020 .020
Typ.

3.25 2.50
1.75
4.25

.220
Dia. .250
Paint Ref.
Hole

11.19

2 Knockouts for 1/2”,
3/4” or 1” Conduit
.281 Diameter Knockout
1 Required

6.000
.020

6.000
.020

6.000
.020

10.120
.020

KO (10)

KO (10)

11.000
+.000 -.030

10.850
.020

KO (10)

4.000
.020

.16

4 Knockouts for 2-1/2”,
3”, 3-1/2” or 4” Conduit

.200 .020
Typ.

8.00
8.00

.780 .020
Typ.

4.00

A

19.40

5
5
5

5

1.500
.020

2.125
.020

4.250
.020

5.125
.020

7.250
.020

.220
Dia.
Paint
Hole

7.250
.020

7.250
.020

.150 .020
Typ.

.350
Ref.
KO (11)

10.140
.020

KO (11)

10.850
.020

.130
.030
6.000
.010

6.000
.010

3”, 3-1/2”, 4”, 5”
Knockout Per A50-26327
5 Knockouts Required

6.000
.010

6.000
.010

.169 .002 Diameter
5 Holes Required at ”X”

KO (11)

11.000
+.000
–.030

4.000
.020

.685 .020
Typ.

.125
.030

.120
.020
Typ.

4.440
.020

Knockout 8
22.54
11.62

.61

.281 Dia. Knockout 1 Required

3.75

10.38

2.50

2 Knockouts for
1/2", 3/4", or 1" Conduit

1.93

3.25 2.50
1.75

5

.150
.020
Typ.
.350
Ref.

KO (11)

.45

5

5

6.000
.010

1.440
.020

Knockout 4

5

5

6.000
.010

2.750
.010

5

5

6.000
.010

6.000
.010

32.120 .020
6.000
.010

2.750
7.500 .010
.020
2.750
.010

5
5

2.125
.020

3/4”, 1”, 1-1/4”, 1-1/2” Knockout
Per A50-26319 1 Knockout Required

4.000
.020
.380
.020

5
5

Knockout 7

Knockout 3

4 Knockouts for 2-1/2",
3", 3-1/2" or 4" Conduit
24.38

2 Knockouts for
1/2", 3/4", or 1" Conduit

8.00

4.00
8.00

4.25

11.19

2 Knockouts for 1/2”,
3/4” or 1” Conduit
.281 Diameter Knockout
1 Required
4 Knockouts for 2-1/2”,
3”, 3-1/2” or 4” Conduit
B

4.25
.16

4.75 3.13

1.75

1.75

2.50

8.00
8.00

4.00

1.50

0.50

19.40

15.38
16.63
2.50

3.63
27.13

5
V1-T5-112

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

3.75
2.13

11.25

Metering Products
Group Metering

5.10

Approximate Dimensions in Inches (mm)

5

Layout—Main Fusible Switch

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-113

5.10
5
5
5

Metering Products
Group Metering

Approximate Dimensions in Inches (mm)
Main Circuit Breaker—“T-Opposite” Phasing Right

8.48
(215.4)
CLVertical

Wall

5

Main Circuit Breaker—“Standard T” Phasing Right

8.48
(215.4)
CLVertical

Wall

5
5

Meter
Center
Front

5

T-Opposite

38.76
(984.5)

5

T-Opposite

5

Meter
Center
Front
38.76
(984.5)

CL Horizontal

18.17
(461.5)

18.17
(461.5)

5

T-Opposite

20.00
(508.0)
6.00
(152.4)

5

T-Opposite

5

CL Horizontal

20.00
(508.0)

30.08
(764.0)

6.00
(152.4)

30.08
(764.0)

Floor

5

Floor

5
5
5

Main Circuit Breaker—“T-Opposite” Phasing Left

Main Circuit Breaker—“Standard T” Phasing Left

5
5

8.48 Wall
(215.4)
CLVertical

8.48 Wall
(215.4)
CLVertical

5
5
Meter
Center
Front
T-Opposite

5
5

T-Opposite

5

38.76
(984.5)

38.76
(984.5)

CL Horizontal

18.17
(461.5)

5

5

T-Opposite

30.08
(764.0)

T-Opposite

5
5

Meter
Center
Front

18.17
(461.5)

20.00
(508.0)
6.00
(152.4)

20.00
(508.0)
30.08
(764.0)

6.00
(152.4)

Floor
Floor

5
5
5
V1-T5-114

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

CL Horizontal

Metering Products
Group Metering

5.10

Contents

Surge Metering

Description

Surge suppression devices shown are factory mounted in
Group Metering Enclosure.

Page

Systems for Residential and Commercial
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type CCV 120/240V Tenant Main Circuit Breaker .
Type CV 120/240V Tenant Main Circuit Breaker . .
Meter Packs—1MP, 1MM and 3MM Main
Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . .
Main Service Modules . . . . . . . . . . . . . . . . . . . . .
Surge Metering
Residential Meter Stacks. . . . . . . . . . . . . . . . . . . .
1MP, 1MM and 3MM Main Tenant
Circuit Breakers. . . . . . . . . . . . . . . . . . . . . . . . . .
Phase Balanced Stack . . . . . . . . . . . . . . . . . . . . . .
Commercial Meter Stack Modules . . . . . . . . . . . .
35MM, 37MM, 35SS and 37SS
Main Tenant Circuit Breakers . . . . . . . . . . . . . . .

V1-T5-88
V1-T5-90
V1-T5-95
V1-T5-96
V1-T5-98
V1-T5-101

5
5
5
5
5
5

V1-T5-116

5

V1-T5-125
V1-T5-126
V1-T5-127

5

V1-T5-134

5

5
5

Surge Metering
Product Description
Eaton’s multiple metering
product family is proud to
announce the availability of
main surge devices. The new
main surge is mounted
between the main service
module and the meter stacks
and serves the purpose of
providing surge protection
for downstream multiple
metering products. The main
surge is compatible with
all meter stacks currently
manufactured (1MM, 3MM,
35MM and 37MM).

Features, Benefits
and Functions
●

●

●

●

Uses thermally protected
metal oxide varistor (MOV)
technology
Compatible with 37MM
enclosure accessories
Protection status indicator
lights EMI/RFI filtering and
audible alarms
Offers surge protection for
all units fed from a main
service module

Standards and Certifications
●
●

●

Benefit for building/complex
owners who want to offer
surge protection to their
tenants. Owner can market
their apartment complex as
being surge friendly to
appliances and electronics
Attain local utility
company approval. Not
for use in EUSERC area

UL 1449 3rd Edition
recognized component

5
5
5
5
5
5
5
5

Product Selection

5

Surge Metering

5

Voltage

Surge Current
per Phase (kA)

Diagnostics

Catalog
Number

5

120/240V single-phase

100

Standard

1MMSURGE

208Y/120V three-phase

100

Standard

3MMSURGE

5
5
5
5
5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-115

5.10
5

Metering Products
Group Metering

Contents

1MM and 3MM Metering Stack Modules

Description

5
5
5
5
5
5
5
5
5
5

Residential Meter Stacks

5

Features, Benefits and Functions

5
5
5
5
5
5
5
5
5
5
5
5
5
5

Page

Systems for Residential and Commercial
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type CCV 120/240V Tenant Main Circuit Breaker .
Type CV 120/240V Tenant Main Circuit Breaker . .
Meter Packs—1MP, 1MM and 3MM Main
Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . .
Main Service Modules . . . . . . . . . . . . . . . . . . . . .
Surge Metering. . . . . . . . . . . . . . . . . . . . . . . . . . .
Residential Meter Stacks
1MP, 1MM and 3MM Main Tenant
Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . .
Phase Balanced Stack. . . . . . . . . . . . . . . . . . . . . .
Commercial Meter Stack Modules . . . . . . . . . . . .
35MM, 37MM, 35SS and 37SS
Main Tenant Circuit Breakers . . . . . . . . . . . . . . .

A. Barrier
Meter socket and tenant
main breaker/wireway
sections are separated by a
solid metal barrier to guard
unmetered bus against
power theft.
B. Tenant Breaker
Reliable busbar–to–busbar
connection. 200A modules
accept bolt-on breakers 60–
200A. 125A modules accept
15–125A plug-on breakers.
C. Moveable Phase Connector
Four-wire horizontal bus lets
you use any 3MM module
for single- or three-phase
incoming service. Shipped
with A and B phase
connection, phase balancing
is easily accomplished in the
field by moving one, frontaccessible phase connector
post per module.
D. Neutral Assembly
A convenient termination for
neutral conductors is in the
wireway of each module.

5
5
5

E. Enclosed Horizontal Bus
Added security because a
non-removable barrier
encloses the 800 or 1200A
horizontal bus passing
through tenant breaker
section.
F. Equipment Ground Bar
Factory installed in side
gutter, a standard feature
that’s moveable to the top or
bottom gutter.
G. Raintight Cap
Shipped on each outdoor
meter module and main
device.
H. Knockouts
Tangential in bottom endwall.
I. Superior Finish
Rust inhibiting phosphate
primer and gray baked
enamel is standard. All
outdoor enclosures are of
galvanized steel construction.

K. Bus Connection
Mains and modules slip
together quickly and
smoothly with frontaccessible captive bolts
securing the juncture without
removing socket interiors or
bus access plate. Main bus
joint bolts torque to 25 foot
pounds.
L. Separate Wireway Cover
Separate covers allow easy
access to tenant breaker and
wireway section, permit work
on breakers or in wireway
without disturbing meters or
meter covers. (Not shown.)

5
V1-T5-116

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-98
V1-T5-101
V1-T5-115

V1-T5-125
V1-T5-126
V1-T5-127
V1-T5-134

1MM Meter Stack Module
G
A

M

B

J
I

C

D
E

M. Vertical Busbar
One-piece vertical busbar
from phase balancing joints to
meter socket eliminating any
chance for hot spots.

J. Meter Socket
Our unique meter socket
base is installed without any
fasteners—reducing chances
for hot spots, easily
replaceable, and improves
connection to vertical bus.

V1-T5-88
V1-T5-90
V1-T5-95
V1-T5-96

K

F
H

Metering Products
Group Metering

●

●

●

Eaton’s 1MM stacks are
single-phase in, singlephase out design
Eaton’s 3MM stacks are
three-phase in, singlephase out design
Stacks with single-phase
horizontal bus are rated
240/120V, single-phase,
three-wire. Stacks with
three-phase horizontal bus
are rated 208Y/120V, threephase, four-wire, but can
be used on 240/120V,
three-phase, four-wire
delta systems

●

All three-phase horizontal
bus modules have fourwire cross bus, connected
A-B phase to vertical bus,
readily reconnectable for
phase balance on
installation

Note: Individual sockets cannot be
phase balanced, only each stack.
●

Short-circuit ratings up to
100,000A rms symmetrical
depending upon AIC rating
of installed main tenant
circuit breakers and
main device

●

●

●

●

Main tenant feeders can
exit bottom or back.
Knockouts are available
at all exit locations
If being used in outdoor
application and exiting the
top, mount Myer type hubs
on rainproof cap
Provision for two-pole
breaker (plug-on type for
125A sockets and bolt-on
type for 200A sockets)—
circuit breakers not
included
Mechanically and
electrically built to bolt-up
with main service modules
and commercial modular
metering stacks

●
●

●

●

5.10

Aluminum or copper bus
800 or 1200A horizontal
bus
All 3MM stacks include
fifth jaw at 9 o’clock
position
All 1MM stacks do not
include fifth jaw. Order
1MM5JK if needed

5
5
5
5
5
5
5
5
5

Catalog Number Selection

5
1 MM 4 12 R

5

12 C

5
Phases
1 = Single-phase
3 = Three-phase
Type of Metering
MM = Multiple metering

Number of Meters
2, 3, 4, 5 or 6
Blank = Accessory
Ampere Rating
12
= 125A
20
= 200A
Blank = Accessory
Enclosure
R
= Outdoor
Blank = Indoor

Options
Blank = Ring
RL
= Ringless
RLB = Ringless with horn bypass
WB = Wall bracket (accessory)
BSK = Bussed spacer (accessory)
EB12 = 12-inch (304.8 mm) elbow (accessory)
EB16 = 16-inch (406.4 mm) elbow (accessory)

Bus Type
Blank = Aluminum
C
= Copper

5
5
5
5

Bus Amperes
12
= 200A horizontal bus (3MM units only)
Blank = Standard 800A bus

5
5

When Ordering:
1. Determine catalog number of Main Service Module.

5

2. Determine catalog number of Meter Stack (Residential or Commercial).

5

3. Find quantity and catalog numbers for tenant circuit breakers (found on Page V1-T5-125 or V1-T5-135).
Order one breaker per socket.

5

4. If any accessories are needed, order from Pages V1-T5-136 and V1-T5-137.

5
5
5
5
5
5
5
5
5
Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-117

5.10
5
5
5

Metering Products
Group Metering

Product Selection
1MM and 3MM
Metering Stack
Modules

800A Horizontal Aluminum Bus—Standard Offering

Amperes
Per
Meter
Socket

5
5

Number of
Meter
Sockets

Bus
Ampacity

Enclosure
Type 1

Main Tenant Breaker Type
(For Specific Catalog Numbers,
Refer to Page V1-T5-125)

Single-Phase In,
Single-Phase Out

Three-Phase In,
Single-Phase Out

Single-Phase Horizontal Bus
(Three Horizontal Busbars—
A, B and Neutral) 2

Three-Phase Horizontal Bus
(Four Horizontal Busbars—
A, B, C and Neutral)

Catalog Number

Catalog Number

Use three-phase

3MM212R

Ring Style Meter Socket Covers
125 3

5
5
5

200 5

5
5
5

24

800

Indoor/outdoor

34

800

Indoor/outdoor

4

800

Indoor/outdoor

Plug-on type
BR2_
BRH2_
BRHH2_

1MM312R

3MM312R

1MM412R

3MM412R

5

800

Indoor/outdoor

1MM512R

3MM512R

6

800

Indoor/outdoor

1MM612R

3MM612R

2

800

Outdoor

Use three-phase

3MM220R

3

800

Outdoor

1MM320R

3MM320R

4

800

Outdoor

5

800

Outdoor

Bolt-on type
CCV2_X
CCVH2_X
CVS2_XMM
CV2_XMM
CVH2_XMM

1MM420R

3MM420R

1MM520R 6

3MM520R 5

Ringless Style Meter Socket Covers
125

2

800

Outdoor

3

800

Outdoor

5

4

800

Outdoor

5

800

5

6
2

5

200

5
5
5

Use three-phase

3MM212RRL

1MM312RRL

3MM312RRL

1MM412RRL

3MM412RRL

Outdoor

1MM512RRL

3MM512RRL

800

Outdoor

1MM612RRL

3MM612RRL

800

Outdoor

Use three-phase

3MM220RRL

1MM320RRL

3MM320RRL

3

800

Outdoor

4

800

Outdoor

5

Plug-on type
BR2_
BRH2_
BRHH2_

800

Outdoor

Bolt-on type
CCV2_X
CCVH2_X
CVS2_XMM
CV2_XMM
CVH2_XMM

1MM420RRL
1MM520RRL

3MM420RRL
6

3MM520RRL 5

Ringless Style Covers with Horn Bypass
125

5
5
5

200

5
5
5

2

800

Outdoor

3

800

Outdoor

4

800

Outdoor

Plug-on type
BR2_
BRH2_
BRHH2_

Use three-phase

3MM212RRLB

1MM312RRLB

3MM312RRLB

1MM412RRLB

3MM412RRLB

5

800

Outdoor

1MM512RRLB

3MM512RRLB

6

800

Outdoor

1MM612RRLB

3MM612RRLB

2

800

Outdoor

3

800

Outdoor

4

800

Outdoor

5

800

Outdoor

Bolt-on type
CCV2_X
CCVH2_X
CVS2_XMM
CV2_XMM
CVH2_XMM

Use three-phase

3MM220RRLB

1MM320RRLB

3MM320RRLB

1MM420RRLB

3MM420RRLB

1MM520RRLB 6

3MM520RRLB 5

Notes
1 For indoor applications where a top endwall with knockouts is needed, order one of part number MM12N1WLK for each 125A stack
or MM20N1WLK for each 200A stack.
2 1MM units do not come with 5th jaw.
3 To change in field from ring to ringless—order 1MMRC125.
4 To change in field from ring to ringless, the top socket in 125A, two- and three-high stacks use 1MMRC125T. Top socket only—other sockets see 3.
5 To change in field from ring to ringless—order 1MMRC200.
6 Check with local utility for height requirements or restrictions.

5
5
5
5
5
5
5
V1-T5-118

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

5.10

Metering Products
Group Metering

1MM and 3MM
Metering Stack
Modules

800A Horizontal Copper Bus—Premium Offering

Amperes
Per
Meter
Socket

Number of
Meter
Sockets

Bus
Ampacity

Enclosure
Type 1

Main Tenant Breaker Type
(For Specific Catalog Numbers,
Refer to Page V1-T5-125)

5

Single-Phase In,
Single-Phase Out

Three-Phase In,
Single-Phase Out

Single-Phase Horizontal Bus
(Three Horizontal Busbars—
A, B, C and Neutral) 2

Three-Phase Horizontal Bus
(Four Horizontal Busbars—
A, B, C and Neutral)

Catalog Number

Catalog Number

Use three-phase

3MM212RC

200

5

24

800

Outdoor

34

800

Outdoor

4

800

Outdoor

5

800

6
2

Plug-on type
BR2_
BRH2_
BRHH2_

1MM312RC

3MM312RC

1MM412RC

3MM412RC

Outdoor

1MM512RC

3MM512RC

800

Outdoor

1MM612RC

3MM612RC

800

Outdoor

Use three-phase

3MM220RC

3

800

Outdoor

4

800

Outdoor

5

800

Outdoor

Bolt-on type
CCV2_X
CCVH2_X
CVS2_XMM
CV2_XMM
CVH2_XMM

1MM320RC

3MM320RC

1MM420RC

3MM420RC

1MM520RC 6

3MM520RC 5

Use three-phase

3MM212RRLC

5
5
5
5
5
5

Ringless Style Meter Socket Covers
125

200

2

800

Outdoor

3

800

Outdoor

4

800

Outdoor

Plug-on type
BR2_
BRH2_
BRHH2_

1MM312RRLC

3MM312RRLC

1MM412RRLC

3MM412RRLC

5

800

Outdoor

1MM512RRLC

3MM512RRLC

6

800

Outdoor

1MM612RRLC

3MM612RRLC

2

800

Outdoor

Use three-phase

3MM220RRLC

3

800

Outdoor

4

800

Outdoor

5

800

Outdoor

Bolt-on type
CCV2_X
CCVH2_X
CVS2_XMM
CV2_XMM
CVH2_XMM

5
5
5
5

1MM320RRLC

3MM320RRLC

1MM420RRLC

3MM420RRLC

1MM520RRLC 6

3MM520RRLC 5

5

Use three-phase

3MM212RRLBC

5

Ringless Style Covers with Horn Bypass
125

200

2

800

5
5

Ring Style Meter Socket Covers
125 3

5

Outdoor

3

800

Outdoor

4

800

Outdoor

Plug-on type
BR2_
BRH2_
BRHH2_

1MM312RRLBC

3MM312RRLBC

1MM412RRLBC

3MM412RRLBC

5

800

Outdoor

1MM512RRLBC

3MM512RRLBC

6

800

Outdoor

1MM612RRLBC

3MM612RRLBC

2

800

Outdoor

Use three-phase

3MM220RRLBC

3

800

Outdoor

1MM320RRLBC

3MM320RRLBC

4

800

Outdoor

1MM420RRLBC

3MM420RRLBC

5

800

Outdoor

1MM520RRLBC 6

3MM520RRLBC 5

Bolt-on type
CCV2_X
CCVH2_X
CVS2_XMM
CV2_XMM
CVH2_XMM

5
5
5
5
5
5

Notes
1 For indoor applications where a top endwall with knockouts is needed, order (1) of part number MM12N1WLK for each 125A stack
or MM20N1WLK for each 200A stack.
2 1MM units do not come with 5th jaw.
3 To change in field from ring to ringless—order 1MMRC125.
4 To change in field from ring to ringless, the top socket in 125A, two- and three-high stacks use 1MMRC125T. Top socket only—other sockets see 3.
5 To change in field from ring to ringless—order 1MMRC200.
6 Check with local utility for height requirements or restrictions.

5
5
5
5
5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-119

5.10
5
5

1MM and 3MM
Metering Stack
Modules

Metering Products
Group Metering

1200A Horizontal Aluminum Bus—Standard Offering
Three-Phase In, Single-Phase Out
Amperes
Per
Meter
Socket

5

Number of
Meter
Sockets

Bus
Ampacity

Enclosure
Type 1

Main Tenant Breaker Type
(For Specific Catalog Numbers,
Refer to Page V1-T5-116)

Three-Phase Horizontal Bus
(Four Horizontal Busbars—
A, B, C and Neutral)
Catalog Number

Ring Style Meter Socket Covers

5

125 2

5
5

23

1200

Indoor/outdoor

33

1200

Indoor/outdoor

4

1200

Indoor/outdoor

5

1200

Indoor/outdoor

6

1200

Indoor/outdoor

2

1200

Outdoor

5

3

1200

Outdoor

4

1200

Outdoor

5

5

1200

Indoor/outdoor

5

200 4

Plug-on type
BR2_
BRH2_
BRHH2_

3MM212R12
3MM312R12
3MM412R12
3MM512R12
3MM612R12

Bolt-on type
CCV2_X
CCVH2_X
CVS2_XMM
CV2_XMM
CVH2_XMM

3MM220R12
3MM320R12
3MM420R12
3MM520R12

Ringless Style Meter Socket Covers (5th Jaw at 9 o’Clock Standard—Field Adjustable to 3 or 6 o’Clock)

5

125

2

1200

Outdoor

5

3

1200

Outdoor

4

1200

Outdoor

5

5

1200

Outdoor

3MM512R12RL

6

1200

Outdoor

3MM612R12RL

5

200

2

1200

Outdoor

5

3

1200

Outdoor

4

1200

Outdoor

5

5

1200

Outdoor

Plug-on type
BR2_
BRH2_
BRHH2_

Bolt-on type
CCV2_X
CCVH2_X
CVS2_XMM
CV2_XMM
CVH2_XMM

3MM212R12RL
3MM312R12RL
3MM412R12RL

3MM220R12RL
3MM320R12RL
3MM420R12RL
3MM520R12RL

Ringless Style Covers with Horn Bypass (5th Jaw at 9 o’Clock Standard—Field Adjustable to 3 or 6 o’Clock)

5

125

2

1200

Outdoor

5

3

1200

Outdoor

4

1200

Outdoor

5

5

1200

Outdoor

6

1200

Outdoor

2

1200

Outdoor

3

1200

Outdoor

4

1200

Outdoor

5

1200

Outdoor

5

200

5
5

Plug-on type
BR2_
BRH2_
BRHH2_

3MM212R12RLB
3MM312R12RLB
3MM412R12RLB
3MM512R12RLB
3MM612R12RLB

Bolt-on type
CCV2_X
CCVH2_X
CVS2_XMM
CV2_XMM
CVH2_XMM

3MM220R12RLB
3MM320R12RLB
3MM420R12RLB
3MM520R12RLB

Notes
1 For indoor applications where a top endwall with knockouts is needed, order (one) of part number MM12N1WLK for each 125A stack or
MM20N1WLK for each 200A stack.
2 To change in field from ring to ringless—order 1MMRC125.
3 To change in field from ring to ringless, the top socket in 125A, two- and three-high stacks use 1MMRC125T. Top socket only—other sockets see 2.
4 To change in field from ring to ringless—order 1MMRC200.

5
5
5
5
5
5
5
5
5
V1-T5-120

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Metering Products
Group Metering

1MM and 3MM
Metering Stack
Modules

5.10

1200A Horizontal Copper Bus—Premium Offering
Three-Phase In, Single-Phase Out
Amperes
Per
Meter
Socket

Number of
Meter
Sockets

Bus
Ampacity

Enclosure
Type 1

Main Tenant Breaker Type
(For Specific Catalog Numbers,
Refer to Page V1-T5-116)

5

Three-Phase Horizontal Bus
(Four Horizontal Busbars—
A, B, C and Neutral)

5

Catalog Number

Ring Style Meter Socket Covers
125 2

200 4

23

1200

Indoor/outdoor

33

1200

Indoor/outdoor

4

1200

Indoor/outdoor

5

1200

Indoor/outdoor

6

1200

Indoor/outdoor

2

1200

Outdoor

3

1200

Outdoor

4

1200

Outdoor

5

1200

Outdoor

Plug-on type
BR2_
BRH2_
BRHH2_

5

3MM212R12C
3MM312R12C

5

3MM412R12C
3MM512R12C

5

3MM612R12C
Bolt-on type
CCV2_X
CCVH2_X
CVS2_XMM
CV2_XMM
CVH2_XMM

3MM220R12C

5

3MM320R12C
3MM420R12C

5

3MM520R12C

5

Ringless Style Meter Socket Covers (5th Jaw at 9 o’Clock Standard—Field Adjustable to 3 or 6 o’Clock)
125

200

2

1200

Outdoor

3

1200

Outdoor

4

1200

Outdoor

5

1200

Outdoor

3MM512R12RLC

6

1200

Outdoor

3MM612R12RLC

2

1200

Outdoor

3

1200

Outdoor

4

1200

Outdoor

5

1200

Outdoor

Plug-on type
BR2_
BRH2_
BRHH2_

Bolt-on type
CCV2_X
CCVH2_X
CVS2_XMM
CV2_XMM
CVH2_XMM

3MM212R12RLC

5

3MM312R12RLC
3MM412R12RLC

5
5

3MM220R12RLC
3MM320R12RLC

5

3MM420R12RLC
3MM520R12RLC

5

Ringless Style Covers with Horn Bypass (5th Jaw at 9 o’Clock Standard—Field Adjustable to 3 or 6 o’Clock)
125

200

2

1200

Outdoor

3

1200

Outdoor

4

1200

Outdoor

5

1200

Outdoor

6

1200

Outdoor

2

1200

Outdoor

3

1200

Outdoor

4

1200

Outdoor

5

1200

Outdoor

Plug-on type
BR2_
BRH2_
BRHH2_

5

3MM212R12RLBC
3MM312R12RLBC

5

3MM412R12RLBC
3MM512R12RLBC

5

3MM612R12RLBC
Bolt-on type
CCV2_X
CCVH2_X
CVS2_XMM
CV2_XMM
CVH2_XMM

5

3MM220R12RLBC

5

3MM320R12RLBC
3MM420R12RLBC

5

3MM520R12RLBC

5

Technical Data and Specifications

5

Wire Sizes—Neutral and Ground Lugs
●
Each stack includes a neutral and ground bar
●
If an extra ground bar is needed, order 1MMGBK

5
5

Wire Sizes—Neutral and Ground Lugs
Lugs in Meter
Socket Modules

Wire Size,
Al/Cu

5

Branch neutral—125A socket module

#6–2/0 kcmil

Branch neutral—200A socket module

#1/0–300 kcmil

5

Equipment ground bar—125A socket module

#14–#2 kcmil

Equipment ground bar—200A socket module

#14–2/0 kcmil

Optional ground bar (1MMGBK)

#6–2/0 kcmil

5
5

Notes
1 For indoor applications where a top endwall with knockouts is needed, order (one) of
part number MM12N1WLK for each 125A stack
or MM20N1WLK for each 200A stack.
2 To change in field from ring to ringless—order 1MMRC125.
3 To change in field from ring to ringless, the top socket in 125A, two- and three-high
stacks use 1MMRC125T. Top socket only—other sockets see 2.
4 To change in field from ring to ringless—order 1MMRC200.

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

5
5
5
V1-T5-121

5.10

Group Metering

Dimensions
Approximate Dimensions in Inches (mm)

5

Modular Metering Stacks—Aluminum and Copper

5

1MM, 3MM, 125 Amperes
12.26
(311.4)

2.00
(50.8) TYP.

12.26
(311.4)

30.60
(777.2)

9.00
(228.6)

9.00
(228.6)

9.00
(228.6)

9.00
(228.6)
30.60
(777.2)

3.07
(78.0)
4 Meter Device

2, 3 Meter Device

5 Meter Device

5
5

Tangential K.O.'s
3/4, 1, 1-1/4, 1-1/2

6.06
(153.9)

5

2.83
(71.9)

5

2.83
(71.9)

5
5

6.62
(168.1)

2.83
(71.9)
"Z" "Y"
"X"

5
5
2.33
(59.1)

5

2.83
(71.9)

2.83
(71.9)
12.13
(308.1)

5
5
5

"Z" = C OF 1-1/2" Ring
"Y" = C OF 1-1/4" Ring
"X" = C OF 3/4" & 1" Ring
L
L
L

5

2.83
(71.9)

0.125
(3.2)

Top End & Bottom End View for NEMA 1;
Bottom End View for NEMA 3R

Note: Dimensions Apply to 800 and 1200 Ampere Horizontal Bus.

5
V1-T5-122

9.00
(228.6)

To C
L of Main Busbar

9.00
(228.6)

9.00
(228.6)

To C
L of Main Busbar

9.00
(228.6)

(6) KO for
1, 1-2/4 1-1/2
Conduit

9.00
(228.6)

48.50
(1231.9)

5

7.01
(178.0)

12.60
(320.3)

5

A

30.0
(777.2)

5

41.80
(1061.7)

12.61
(320.2)

5

21.65
(550.0)

5

CL Meter to CL Rail Mounting Screw

5

To CL of Wall Mtg. Screw

5

34.25
(870.0)

5

12.26
(311.4)

9.00
(228.6)

This Bus
Omitted
On 1 —
PH Units

9.00
(228.6)

5

57.50
(1460.5)

9.00
(228.6)

12.26
(311.4)

12.60
(320.0)

5

66.50
(1689.1)

9.00
(228.6)

5

12.60
(320.0)

5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

6 Meter Device

A

30.60
(777.2)

To C
L of Main Busbar

5

To C
L of Main Busbar

5

Metering Products

5.10

Metering Products
Group Metering

Approximate Dimensions in Inches (mm)

5

Modular Metering Stacks—Aluminum and Copper

5

1MM, 3MM, 200 Amperes

5

13.50
(342.9)

5

1.70
(43.2) TYP.

5

64.50
(1638.3)

7.01
(178.1)

(4) KO For
1, 1-1/4, 1-1/2, 2
Conduit

12.12
(307.8)

5

12.12
(307.8)

5
5
30.55
(776.0)

To C
L of Main Busbar

To C
L of Main Busbar

5

12.12
(307.8)

12.12
(307.8)
12.12
(307.8)

CL Meter to CL Rail Mtg. Screw

This Bus Omitted on
1-PH Devices

30.55
(776.0)

18.42
(467.9)

34.25
(870.0)

To
L C of Wall Rail Mtg. Screw

15.82
(401.8)

Circuit
Breaker
Covers
Omitted
On NEMA
1 Devices

18.42
(467.9)

52.35
(1329.7)

5

5
5
5
5

1.75 TYP.
(44.5)

2, 3 Meter Device

5

5

4 Meter Device

5
5
13.36
(339.3)
6.59
(167.4)

0.12
(3.0)

5

3.38
(85.9)

5

3.00
(76.2)

5

1.76
(44.7)

6.62
(168.1)

5
5

(6) Cocentric K.O.'s
1", 1-1/4", 1-1/2", 2"

3.29
(83.6)

3.29
(83.6)

1.75
(44.5)

5
5

3.29
(83.6)

5

Bottom View

5

Note: Dimensions Apply to 800 and 1200 Ampere Horizontal Bus.

5
5
5
Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-123

5.10

Metering Products
Group Metering

5

Approximate Dimensions in Inches (mm)

5

5-High, 200 Amperes, 1MM and 3MM Metering

5

1.70
(43.2)

6.87
(174.5)
Typ.

5

13.50
(342.9)

5
5
5

12.13
(308.1)

5
5

12.13
(308.1)

5
5

74.96
(1904.0) 12.13

5

(308.1)

5
5
5
5
5

12.13
(308.1)

33.27
(845.1)
Typ.
to
CL
of Wall
Mtg.
Screw

28.88 to
CL of Main
Busbar

2.74
(69.6)
3.85
(97.8)

5
5

0.45
(11.4)
Typ.

5
5

1.87
(47.5)

16.76
(425.7)

(5) Concentric
K.O.'s
1", 1-1/4",
1-1/2", 2"

1.75 (44.5)

1.61
3.21
(40.9)
(81.5)
3.21
(81.5)
3.21
(81.5)

Residential
Device

13.36
(339.3)

5
0.12
(3.0)

5

6.59
(167.4)

3.38
(85.9)

1.76
(44.7)

6.62
(168.1)

5
5
(6) Cocentric K.O.'s
1", 1-1/4", 1-1/2", 2"

5

5

3.29
(83.6)

3.29
(83.6)

1.75
(44.5)

3.29
(83.6)

5
5

3.00
(76.2)

Bottom View

Note: The Bussed meter stack device shown on the far right of the figure, must be used on Mains with Busway connections, found on Pages V1-T5-109 and V1-T5-113. Please contact factory for
catalog numbers associated with Bussed meter stack devices.

5
V1-T5-124

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Metering Products
Group Metering

5.10

Contents

1MM and 3MM Metering Circuit Breakers

Description

Page

Systems for Residential and Commercial
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type CCV 120/240V Tenant Main Circuit Breaker .
Type CV 120/240V Tenant Main Circuit Breaker . .
Meter Packs—1MP, 1MM and 3MM Main
Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . .
Main Service Modules . . . . . . . . . . . . . . . . . . . . .
Surge Metering . . . . . . . . . . . . . . . . . . . . . . . . . . .
Residential Meter Stacks. . . . . . . . . . . . . . . . . . . .
1MP, 1MM and 3MM Main Tenant
Circuit Breakers
Phase Balanced Stack . . . . . . . . . . . . . . . . . . . . . .
Commercial Meter Stack Modules . . . . . . . . . . . .
35MM, 37MM, 35SS and 37SS
Main Tenant Circuit Breakers . . . . . . . . . . . . . . .

CV2200

V1-T5-88
V1-T5-90
V1-T5-95
V1-T5-96
V1-T5-98
V1-T5-101
V1-T5-115
V1-T5-116

V1-T5-126
V1-T5-127
V1-T5-134

5
5
5
5
5
5
5
5
5
5

1MP, 1MM and 3MM Main Tenant Circuit Breakers

5

Product Description

5

Specific main tenant circuit
breakers that are to be
used in meter packs (1MP),
residential meter stacks
(1MM) and three-phase in
single-phase out meter
stacks (3MM).

5
5
5
5

Product Selection

Description

10 kAIC

22 kAIC

25 kAIC

42 kAIC

65 kAIC

100 kAIC

Number
of Poles

Catalog
Number 1

Catalog
Number

Catalog
Number 1234

Catalog
Number 234

Catalog
Number 234

Catalog
Number 234

2

60

BR260

BRH260

—

BRHH260

—

—

2

70

BR270

BRH270

—

BRHH270

—

—

2

80

BR280

BRH280

—

BRHH280

—

—

2

90

BR290

BRH290

—

BRHH290

—

—

2

100

BR2100

BRH2100

—

BRHH2100

—

—

2

110

BR2110

BRH2110

—

BRHH2110

—

—

2

125

BR2125

BRH2125

—

BRHH2125

—

—

5
5

5
5
5

Bolt-On Type
Bolt-on type circuit breakers used with 2
1MP, 1MM, and 3MM 200A modular 2
metering stacks
2

60

—

—

CVS2060XMM

CVS2060XMM

CV2060XMM

CVH2060XMM

70

—

—

CVS2070XMM

CVS2070XMM

CV2070XMM

CVH2070XMM

80

—

—

CVS2080XMM

CVS2080XMM

CV2080XMM

CVH2080XMM

2

90

—

—

CVS2090XMM

CVS2090XMM

CV2090XMM

CVH2090XMM

2

100

CCV2100X

—

CCVH2100X

CVS2100XMM

CV2100XMM

CVH2100XMM

2

125

CCV2125X

—

CCVH2125X

CVS2125XMM

CV2125XMM

CVH2125XMM

2

150

CCV2150X

—

CCVH2150X

CVS2150XMM

CV2150XMM

CVH2150XMM

2

175

CCV2175X

—

CCVH2175X

CVS2175XMM

CV2175XMM

CVH2175XMM

2

200

CCV2200X

—

CCVH2200X

CVS2200XMM

CV2200XMM

CVH2200XMM

Notes
1 #2–300 kcmil wire size range for CCV and CCVH tenant main circuit breakers.
2 “MM” suffix indicates mounting hardware kit is included as standard with tenant main breaker.
3 1MMCBK replacement mounting hardware kit. One kit is needed per breaker. Mounting hardware kit ships standard with breaker “MM” suffix offering.
4 #6–4/0 kcmil wire size range for CVS, CV and CVH tenant main circuit breakers. If #2–300 kcmil is needed, order 2TA225CVK. One kit needed per breaker.
Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

5
5

Plug-On Type
Plug-on type circuit breakers used
with 1MP, 1MM, and 3MM 125A
modular metering stacks

5

Main Tenant
Circuit Breaker
Ampere Rating

5
5
5
5
5
5

V1-T5-125

5.10

Metering Products
Group Metering

Contents

5

Description

5
5
5
5
5
5
5
5
5
5

Phase Balanced Stack

5

Product Description

Features

Eaton’s Phase Balanced
Stack allows for a complete
phase balanced metering lineup using fewer stacks. With
today’s electrical rooms
becoming smaller, the need
is greater than ever to offer
space-saving metering
products while providing a
fully phase balanced system.
The new phase balanced
stack is the answer.

●

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

Page

Systems for Residential and Commercial
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type CCV 120/240V Tenant Main Circuit Breaker .
Type CV 120/240V Tenant Main Circuit Breaker . .
Meter Packs—1MP, 1MM and 3MM Main
Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . .
Main Service Modules . . . . . . . . . . . . . . . . . . . . .
Surge Metering. . . . . . . . . . . . . . . . . . . . . . . . . . .
Residential Meter Stacks . . . . . . . . . . . . . . . . . . .
1MP, 1MM and 3MM Main Tenant
Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . .
Phase Balanced Stack
Commercial Meter Stack Modules . . . . . . . . . . . .
35MM, 37MM, 35SS and 37SS
Main Tenant Circuit Breakers . . . . . . . . . . . . . . .

Today, achieving a phase
balanced system when
connected to a 208Y/120 Vac
three-phase, four-wire
system may require one or
two additional 3MM meter
modules. Standard 3MM
meter stacks come factory
connected to phases A and B.
The new phase balanced
stacks connect the two
bottom meters to phases
B and C and the top two or
three meters to phases
A and C. Using these new
stacks with the AB phased
3MM metering, phase
balancing is accomplished,
and more compact than
before.

●
●

●

●
●

Available in four- and
five-high configurations
at 125A
200A stacks available
Available with 800A
aluminum bus and
1200A copper bus
Ring, ringless, ringless
with horn bypass available
Outdoor enclosure
Dimensions same as
existing 125A, three-phase
meter stacks

V1-T5-98
V1-T5-101
V1-T5-115
V1-T5-116
V1-T5-125
V1-T5-127
V1-T5-134

Product Selection
Ordering Information
●
Check with local utility
for height restrictions
●
Items loaded in VISTA

●

If you have questions,
please contact the
Technical Resource Center
1-800-356-1243, option 3

Phase Balanced Stack
Amperes Per
Meter Socket

Bus Ampacity

Meter Socket Cover

Catalog Number

125

800

Ring

3MM412RACBC

125

800

Ring

3MM512RACBC

125

800

Ringless

3MM412RRLACBC

125

800

Ringless

3MM512RRLACBC

125

800

Ringless horn bypass

3MM412RRLBACBC

125

800

Ringless horn bypass

3MM512RRLBACBC

125

1200

Ring

3MM412R2ACBC

125

1200

Ring

3MM512R2ACBC

125

1200

Ringless

3MM412R2RLACBC

125

1200

Ringless

3MM512R2RLACBC

125

1200

Ringless horn bypass

3MM412R2RLBACBC

125

1200

Ringless horn bypass

3MM512R2RLBACBC

Note: Local codes and utility requirements still apply. The phase balance stacks are not
suitable for changing in the field.

5
5
5
V1-T5-126

V1-T5-88
V1-T5-90
V1-T5-95
V1-T5-96

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Metering Products
Group Metering

Commercial Meter Stack Modules (35MM, 37MM, 35SS and 37SS)

5.10

Contents
Description

35MM, 37MM, 35SS and 37SS

Page

Systems for Residential and Commercial
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type CCV 120/240V Tenant Main Circuit Breaker .
Type CV 120/240V Tenant Main Circuit Breaker . .
Meter Packs—1MP, 1MM and 3MM Main
Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . .
Main Service Modules . . . . . . . . . . . . . . . . . . . . .
Surge Metering . . . . . . . . . . . . . . . . . . . . . . . . . . .
Residential Meter Stacks. . . . . . . . . . . . . . . . . . . .
1MP, 1MM and 3MM Main Tenant
Circuit Breakers. . . . . . . . . . . . . . . . . . . . . . . . . .
Phase Balanced Stack . . . . . . . . . . . . . . . . . . . . . .
Commercial Meter Stack Modules
35MM, 37MM, 35SS and 37SS
Main Tenant Circuit Breakers . . . . . . . . . . . . . . .

V1-T5-88
V1-T5-90
V1-T5-95
V1-T5-96
V1-T5-98
V1-T5-101
V1-T5-115
V1-T5-116
V1-T5-125
V1-T5-126

5
5
5
5
5
5
5
5
5

V1-T5-134

5

Commercial Meter Stack Modules

5

Product Description

5

●

●

●

●

Heavy-duty lever bypass
socket design
Single-phase or threephase designs (35 = singlephase, 37 = three-phase)
Provision for two-pole or
three-pole main tenant
breakers
Phase balance kits are
included with three-high
and four-high modules

Features, Benefits
and Functions
A. End Walls
The top cap is removable and
does not contain knockouts,
so contractors can position
and punch holes where they
need them. There are
numerous KOs in the back
and bottom for flexibility.

E. Barrier
A solid metal barrier
separates the meter socket
section from the tenant
breaker in the wireway
section. The unmetered
vertical bus is enclosed to
guard against power theft.

I. Indoor/Outdoor Construction
Raintight caps, meter covers
and lockable raintight tenant
breaker covers make it
convenient for you to use
any of our modules on either
NEMA 1 or NEMA 3R
applications.

B. Ground Bars
The factory-installed
equipment ground bars are
provided in both the top and
bottom gutters.

F. Neutral Assembly
Located in the wireway of
each module, the assembly
permits convenient
termination of the neutral
conductors.

J. Mounting Rail
Rear mounting rail and wall
hanger speed and simplify
installation. (Mounting rail
not shown.)

C. Meter Socket
The 5-jaw meter socket and
7-jaw meter socket includes a
built-in manual bypass and jaw
release. The ground wire is
factory connected in both
35MM and 37MM modules.
D. Separate Wireway Cover
If work on the breakers or
cables is necessary, it can
be accomplished without
disturbing the meters or
meter covers, thanks to a
separate cover that allows
easy access to the module’s
main tenant breaker and
wireway section.
(Not shown.)

G. Enclosed Horizontal Bus
Non-removable metal barrier
encloses 1200A horizontal
bus when passing through
the tenant breaker section
for added security.
H. Tenant Breaker Range
All modules accept 15–225A
bolt-on breakers in various
AIC ratings. The CHH_X
breaker carries a UL listed
series rating of 100,000A,
which allows you to use
standard 10 kAIC breakers in
downstream loadcenters and
panelboards by Eaton.

K. Nameplate and Ratings
The nameplate gives you full
rating data: 208Y/120, threephase, four-wire; 240/120,
three-phase, four-wire delta
(high leg on B-phase); and
240/120 single-phase.
(Not shown.)
L. Mains and Modules
Slip together quickly,
smoothly with frontaccessible captive bolts
securing the juncture without
removing socket interiors or
bus access plate. Main bus
joint bolts torque to 25 foot
pounds.

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-127

5.10
5

Metering Products
Group Metering

37MM Meter Stack Module

5

I

5

H

5

E

5

F

●

5
5

●

●

L

C

G

●

5
5
5

B

5

A

5
5
5

Eaton’s 35MM and 37MM
modular metering stacks
contain meter sockets with
built-in manual bypass and
jaw release (Non-EUSERC
areas)
Eaton’s 35SS and 37SS
stacks use meter sockets
with test bypass feature
(meets EUSERC electrical
requirements)
All commercial modular
metering stacks contain
four horizontal cross buses
Mechanically and
electrically built to bolt-up
with main service modules
and residential modular
metering stacks

Catalog Number Selection
Commercial Meter Stack Modules

5

3 7 MM 1 40 R 12 40 K C

5

Bus
C = Copper
Blank = Aluminum

5
5

Phases
Three-phase only

5

Type of Metering
MM = Commercial metering module
SS = Safety socket—EUSERC

5
5

Number of Meters
1, 2, 3 or 4

5

Socket Type
K = K Base bolt-on socket
Blank = Plug-in type socket

Number of Jaws
5 or 7

Enclosure
R = NEMA 3R

5
5

Tenant Breakers
40 = 400A included
Blank = Ordered separately

Socket Amperage
20 = 200A
40 = 400A

12
AB
AC
BC

Bus
= 1200A main bus ampacity
= Phases A&B—EUSERC
= Phases A&C—EUSERC
= Phases B&C—EUSERC

When Ordering:
1. Determine catalog number of Main Service Module.

5

2. Determine catalog number of Meter Stack (Residential or Commercial).

5

3. Find quantity and catalog numbers for tenant circuit breakers (found on Page V1-T5-134). Order one breaker per socket.

5

4. If any accessories are needed, order from Pages V1-T5-136 and V1-T5-137.

5
5
5
V1-T5-128

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

5.10

Metering Products
Group Metering

Product Selection
35MM
●
Each socket is a 5 terminal
block with lever bypass and
jaw release
●
Ringless covers
●
Provision for two-pole main
tenant breakers (circuit
breakers not included).
For circuit breaker
catalog numbers, refer
to Page V1-T5-134

5
●

Phase balancing kits are
included with three-high
and four-high modules.
Each individual socket can
be phase balanced in the
field to the desired lines
(A-B, B-C or A-C). Comes
from factory as A-B

●

●

●

Indoor/outdoor
construction
Main tenant feeders can
exit top, bottom or back
If being used in outdoor
application and exiting the
top, mount Myer type hubs
on rainproof cap

●

●

Short-circuit ratings up
to 100A rms symmetrical
depending upon the kAIC
rating of installed main
tenant circuit breakers
and main device
Non-EUSERC areas

5
5
5
5
5
5

35MM—Single-Phase Commercial Meter Stack Modules (Three-Phase In, Single-Phase Out)
Horizontal
Bus
Ampacity/
Material

Number of
Jaws Per
Meter Socket

Main Tenant
Breaker Type
(Page V1-T5-134) 1
Bolt-on type
EHD2_
CCV2_X
CCVH2_X
CVS2_XMM
CV2_XMM
CVH2_XMM

5

System
Voltage

Ampere Rating
Per Meter Socket

Number
of Meter
Sockets

120/240V, single-phase, three-wire systems and
208Y/120V network metering (Not suitable for use
on three-phase, four-wire delta systems)

225

1

1200 Al

5

1

1200 Cu

5

2

1200 Al

5

2

1200 Cu

5

3

1200 Al

5

3

1200 Cu

5

35MM320R12C

4

1200 Al

5

35MM420R12

400

400

4

1200 Cu

5

1

1200 Al

5

1

1200 Cu

5

5

Catalog
Number

5

35MM120R12
35MM120R12C

5

35MM220R12

5

35MM220R12C
35MM320R12

5
5

35MM420R12C
400A
K-Frame included

35MM140R1240C 2

5
5

1200 Al

5

1

1200 Cu

5

2

1200 Al

5

2

1200 Cu

5

400 continuous

1

1200 Cu

5

400A
L-Frame included

35MM140R1240K

5

400 continuous

1

1200 Cu

5

400A
L-Frame included

35MM140HR1240KC 4

5

400A
K-Frame included

35MM140HR1240

3

1

400

400A
K-Frame included

35MM140R1240 2

35MM140HR1240C 3
35MM240R1240
35MM240R1240C

Notes
1 Retrofit tenant circuit breaker mounting kit (37MMRCBK) for installation of Type EHD and CV breakers. Needed only for stacks manufactured prior to February 2013. Order one kit per breaker.
2 Unit is bottom exit only.
3 Rated at 100 kAIC.
4 Rated at 35 kAIC.

5

5
5
5
5
5
5
5
5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-129

5.10
5
5
5
5
5

Metering Products
Group Metering

37MM
●
Each socket is a 7 terminal
block with lever bypass and
jaw release
●
Ringless covers
●
Provision for three-pole
main tenant breakers
(circuit breakers not
included). For circuit
breaker catalog numbers,
refer to Page V1-T5-134

●

●

●

Indoor/outdoor
construction
Main tenant breakers can
exit top, bottom or back
If being used in outdoor
application and exiting the
top, mount Myer type hubs
on rainproof cap

●

●

Short-circuit ratings up to
100A rms symmetrical
depending upon the kAIC
rating of installed main
tenant circuit breakers
and main device
Non-EUSERC areas

5
5
5
5

37MM—Three-Phase Commercial Meter Stack Modules (Three-Phase In, Three-Phase Out)

System
Voltage

Ampere Rating
Per Meter Socket

208Y/120V, three-phase, four-wire
240/120V, three-phase, four-wire delta
(B-phase is high leg)

225

Number
of Meter
Sockets

Horizontal
Bus
Ampacity/
Material

Number of
Jaws Per
Meter Socket 1

Main Tenant
Breaker Type 2
(Page V1-T5-134)
Bolt-on type
EHD3_
CC3_X
CVS3_X
CV3_X
CVH3_X

Catalog
Number

1

1200 Al

7

1

1200 Cu

7

2

1200 Al

7

5

2

1200 Cu

7

5

3

1200 Al

7

37MM320R12

3

1200 Cu

7

37MM320R12C

4

1200 Al

7

37MM420R12

4

1200 Cu

7

1

1200 Al

7

1

1200 Cu

7

1200 Al

7

5

5
5

400

37MM120R12
37MM120R12C
37MM220R12
37MM220R12C

37MM420R12C
400A
K-Frame included

37MM140R12 3

400A
K-Frame included

37MM140R1240 4

400A
K-Frame included

37MM140HR1240 5

400A
K-Frame included

37MM240R1240

37MM140R12C 3

5

400

1

5

1

1200 Cu

7

400

1

1200 Al

7

5

1

1200 Cu

7

400

2

1200 Al

7

5

2

1200 Cu

7

400 continuous

1

1200 Cu

7

37MM140R1240KC 6

5

400A
L-Frame included

400 continuous

1

1200 Cu

7

400A
L-Frame included

37MM140HR1240KC 7

5
5
5
5

37MM140R1240C 4

37MM140HR1240C 5

37MM240R1240C

Notes
1 If a socket in a 37MM meter stack module needs to be single-phase, order 37MM1CK. This will convert the three-phase socket to single-phase.
2 Retrofit tenant circuit breaker mounting kit (37MMRCBK) for installation of Type EHD and CV breakers. Needed only for stacks manufactured prior to February 2013. Order one kit per breaker.
3 320A continuous rated socket with provisions for two main tenant breakers.
4 Unit is bottom exit only.
5 Rated at 100 kAIC.
6 Rated at 25 kAIC.
7 Rated at 35 kAIC.

5
5
5
5
5
5
5
V1-T5-130

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Metering Products
Group Metering

35SS
●
Sockets include EUSERC
required test-bypassdisconnect feature
●
Ring type covers
●
Single-phase units have
provisions for two-pole
main tenant breakers

35SS_

When applying 35SS
(single-phase) stacks on
208Y/120V, three-phase,
four-wire and 240/120V,
three-phase, four-wire
delta systems, refer to
suffixes for proper phase
balancing. Each meter
stack module is phase
balanced at the plant
(A-B, B-C or A-C) and
cannot be field modified

●

●

●

Indoor/outdoor
construction
Main tenant breakers can
exit top, bottom or back.
If being used in outdoor
application and exiting the
top, mount Myer type hubs
on rainproof cap

●

5.10

Short-circuit ratings up to
100A rms symmetrical
depending upon the kAIC
rating of installed main
tenant circuit breakers
and main device

5
5
5
5
5
5

35SS—Three-Phase Commercial Meter Stack Modules

5

System
Voltage

Ampere Rating
Per Meter Socket

Number
of Meter
Sockets

Horizontal
Bus
Ampacity/
Material

120/240V, single-phase,
three-wire systems and
208Y/120V network metering
(Not suitable for use on three-phase,
four-wire delta systems)

225

1

1200 Al

5

1200 Cu

5

1200 Al

5

1200 Cu

5

1200 Al

5

1200 Cu

5

35SS120RBCC 2

1200 Al

5

35SS220RAB 2

1200 Cu

5

35SS220RABC 2

1200 Al

5

35SS220RAC 2

1200 Cu

5

35SS220RACC 2

2

3

37SS
●
Sockets include EUSERC
required test-bypassdisconnect feature
●
Ring type covers

5

Number of
Jaws Per
Meter Socket

Main Tenant
Breaker Type 1
(Page V1-T5-134)
Bolt-on type
EHD2_
CCV2_X
CCVH2_X
CVS2_X
CV2_X
CVH2_X

Catalog
Number
35SS120RAB 2
35SS120RABC 2
35SS120RAC 2
35SS120RACC 2
35SS120RBC 2

2

1200 Al

5

35SS220RBC

1200 Cu

5

35SS220RBCC 2
2

1200 Al

5

35SS320RAB

1200 Cu

5

35SS320RABC 2

1200 Al

5

35SS320RAC 2

1200 Cu

5

35SS320RACC 2
2

1200 Al

5

35SS320RBC

1200 Cu

5

35SS320RBCC 2

5
5
5
5
5
5
5
5
5
5
5

Three-phase units have
provisions for three-pole
main tenant breaker

●

●

5

Aluminum horizontal bus
supplied as standard

5
5

37SS—Three-Phase Commercial Meter Stack Modules

System
Voltage

Ampere Rating
Per Meter Socket

Number
of Meter
Sockets

Horizontal
Bus
Ampacity/
Material

208Y/120V, three-phase, four-wire
240/120V, three-phase, four-wire delta
(B-phase is high leg)

225

1

1200 Al

7

1200 Cu

7

1200 Al

7

1200 Cu

7

1200 Al

7

1200 Cu

7

2
3

Number of
Jaws Per
Meter Socket

Main Tenant
Breaker Type 1
(Page V1-T5-134)
Bolt-on type
EHD3_
CC3_X
CVS3_X
CV3_X
CVH3_X

Catalog
Number
37SS120R
37SS120RC
37SS220R
37SS220RC
37SS320R
37SS320RC

Notes
1 Retrofit tenant circuit breaker mounting kit (37MMRCBK) for installation of Type EHD and CV breakers. Needed only for stacks manufactured prior to February 2013. Order one kit per breaker.
2 Last two digits of catalog number indicate phase balancing (AB indicates all sockets in this stack are connected to phases A and B only).

5
5
5
5
5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-131

5.10
5

Metering Products
Group Metering

Approximate Dimensions in Inches (mm)

5

Commercial Stacks (35MM and 37MM)

5

35MM and 37MM
35MM140R1240
37MM140R1240
same as below
except eliminate
top socket.

5
5
5
5
5

14.00
(355.6)
Typ.

5
5

52.63
(1336.7)

25.38
(644.5)

52.63
(1336.7)

66.63
(1692.3)

5
5
5
5
5

8.75
(222.3)

8.75
(222.3)

5
18.25
(463.6)

5

18.25
(463.6)

18.25
(463.6)

5
5
5
5
5
5
5
5
5
5
5
5
5
V1-T5-132

8.75
(222.3)

8.75
(222.3)

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

19.25
(489.0)

Metering Products
Group Metering

5.10

Approximate Dimensions in Inches (mm)

5

Commercial Stacks (35SS and 37SS)

5

35SS and 37SS
21.38
(542.9)
12.00
(304.8)

21.38
(542.9)
12.00
(304.8)

29.38
(746.1)

9.56
(242.9)

19.50
(495.3)

17.75
(450.9)
Centerline 19.50
(495.3)
of Wall
Mounting
Screws

25.00
(635.0)
13.50
(342.9)

2.00 (50.8),
2.50 (63.5)
43.00
(1092.2)

5
5

19.50
(495.3)

31.50
(800.1)

47.38
(1203.3)

5

5

68.88
(1749.4)

KO 1.50 (38.1)

5

5

62.44
(1585.9)
6.50
(165.1)

6.50
(165.1)

6.50
(165.1)

0.41 Dia.
9.56
(10.3)
(242.9)
4-Holes

5

21.38
(542.9)
12.00
(304.8)

9.50
(241.3)

5

5
31.50
(800.1)

5
5
5
5

Wire Seal Slot and Sealing Screw
Ribbon Seal or Barrel Lock Hasp
8.75 Bottom (Typ.)
13.56
(222.3)
(344.5)
Inside

5

3 KOs 1.50 (38.1),
2.00 (50.8), 2.50 (63.5)

5
5
5
5
5
5
5
5
5
5
5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-133

5.10
5

Metering Products
Group Metering

35MM, 37MM, 35SS and 37SS Main Tenant Circuit Breakers

Description

5
5
5
5
5
5
5
5

CV2200/CV3200

5
5
5
5
5
5
5
5
5
5

Contents
Systems for Residential and Commercial
Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Type CCV 120/240V Tenant Main Circuit Breaker .
Type CV 120/240V Tenant Main Circuit Breaker . .
Meter Packs—1MP, 1MM and 3MM Main
Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . .
Main Service Modules . . . . . . . . . . . . . . . . . . . . .
Surge Metering. . . . . . . . . . . . . . . . . . . . . . . . . . .
Residential Meter Stacks . . . . . . . . . . . . . . . . . . .
1MP, 1MM and 3MM Main Tenant
Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . .
Phase Balanced Stack. . . . . . . . . . . . . . . . . . . . . .
Commercial Meter Stack Modules . . . . . . . . . . . .
35MM, 37MM, 35SS and 37SS
Main Tenant Circuit Breakers

35MM, 37MM, 35SS
and 37SS Main Tenant
Circuit Breakers
Product Description
●

●

●

●

The following breakers
are to be used on 35MM,
37MM, 35SS and 37SS
modular metering stacks
Series rating information
available on Pages V1-T5142 through V1-T5-145
Two-pole breakers are
120/240 Vac, field installed
Three-pole breakers are
208Y/120 Vac, field
installed

5
5
5
5
5
5
5
5
5
5
5
V1-T5-134

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Page
V1-T5-88
V1-T5-90
V1-T5-95
V1-T5-96
V1-T5-98
V1-T5-101
V1-T5-115
V1-T5-116
V1-T5-125
V1-T5-126
V1-T5-127

Metering Products
Group Metering

5.10

Product Selection

5
5

35MM, 37MM, 35SS and 37SS Main Tenant Circuit Breakers
10 kAIC

25 kAIC

42 kAIC

65 kAIC

100 kAIC

Main Tenant
Circuit Breaker
Ampere Rating

5

Catalog
Number

Catalog
Number 12

Catalog
Number 12

Catalog
Number 12

Catalog
Number 12

5

Bolt-on type circuit breakers used
2
with 35MM and 35SS (single-phase
2
modular metering stacks) 34
2

60

EHD2060

CVS2060XMM

CVS2060XMM

CV2060XMM

CVH2060XMM

70

EHD2070

CVS2070XMM

CVS2070XMM

CV2070XMM

CVH2070XMM

80

EHD2080

CVS2080XMM

CVS2080XMM

CV2080XMM

CVH2080XMM

2

90

EHD2090

CVS2090XMM

CVS2090XMM

CV2090XMM

CVH2090XMM

2

100

CCV2100X

CCVH2100X

CVS2100XMM

CV2100XMM

CVH2100XMM

2

125

CCV2125X

CCVH2125X

CVS2125XMM

CV2125XMM

CVH2125XMM

2

150

CCV2150X

CCVH2150X

CVS2150XMM

CV2150XMM

CVH2150XMM

2

175

CCV2175X

CCVH2175X

CVS2175XMM

CV2175XMM

CVH2175XMM

2

200

CCV2200X

CCVH2200X

CVS2200XMM

CV2200XMM

CVH2200XMM

2

225

CCV2225X

CCVH2225X

CVS2225XMM

CV2225XMM

CVH2225XMM

3
Bolt-on type circuit breakers used
with 37MM and 37SS (three-phase
3
34
modular metering stacks)
3

60

EHD3060

CVS3060X

CVS3060X

CV3060X

CVH3060X

70

EHD3070

CVS3070X

CVS3070X

CV3070X

CVH3070X

80

EHD3080

CVS3080X

CVS3080X

CV3080X

CVH3080X

3

90

EHD3090

CVS3090X

CVS3090X

CV3090X

CVH3090X

3

100

CC3100X

CVS3100X

CVS3100X

CV3100X

CVH3100X

3

125

CC3125X

CVS3125X

CVS3125X

CV3125X

CVH3125X

3

150

CC3150X

CVS3150X

CVS3150X

CV3150X

CVH3150X

3

175

CC3175X

CVS3175X

CVS3175X

CV3175X

CVH3175X

3

200

CC3200X

CVS3200X

CVS3200X

CV3200X

CVH3200X

3

225

CC3225X

CVS3225X

CVS3225X

CV3225X

CVH3225X

Description

Number
of Poles

Bolt-On Type

Bolt-On Type

Notes
1 #6–4/0 kcmil wire size range for CVS, CV and CVH tenant main circuit breakers. If #2–300 kcmil is needed, order 2TA225CVK (two-pole) 3TA225CVK (three-pole). One kit is needed per breaker.
2 “MM” suffix provides mounting hardware needed for 1MP, 1MM and 3MM modular metering stacks only. Mounting hardware is not needed for use in 35MM and 35SS modular metering stacks, but
is included as standard with breakers.
3 Retrofit tenant circuit breaker mounting kit (37MMRCBK) for installation of Type EHD and CV breakers. Needed only for stacks manufactured prior to February 2013.
Order one kit per breaker.
4 Type EHD main tenant circuit breakers are also available from 15 to 50A.

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-135

5.10
5

Metering Products
Group Metering

Accessories

5

1MP, 1MM and 3MM Modular Metering Stacks

5

Description

Application

Fifth jaw kit

Bolted onto neutral in the 3, 6 or
9 o’clock position. Typically used on
network metering systems (three-phase
in/single-phase out) or when specified
by utility company.

1MM5JK

Isolated
fifth jaw kit

Connects to the neutral
with an insolated wire.

1MM5JKOP

Manual
bypass kit
(ring style
socket only)

For use with 125A sockets only.
(Not top socket.)

1MMBPM125

For use with 200A sockets only.
(Not top socket.)

1MMBPM200
1MMBPM125T

5

This kit only to be used for top
position of two- and three-high 125A 1MM
and 3MM stacks and of 2, 5 and
six-position 125A 1MP packs.

5

This kit only to be used for top position of 200A
two-position 1MP packs.

1MMBPM200T

Used only on ringless cover stacks,
kits can be installed on 125A or
200A sockets.

1MMBPH

5

Fifth Jaw Kit

5
5
5

Manual Bypass Kit

5
5

5

Horn Bypass Kit

Horn bypass

5
5

Note: For 1MP2122RRL use:

WCG8HB 1

Meter bypass
jumper

Installed on 125A or 200A
sockets. Jumpers are plugged into jaws.
Order Lexan® cover plate with
bypass jumpers to prevent access
to meter socket once energized. (Not UL listed.)

1MMBPJ

Lexan blank
cover

Circular cover mounted on ring or
ringless devices preventing access
to meter socket while meter is not in
place. Includes four plastic tabs
that plug into each jaw.

1MMPCP

Same as 1MMPCP minus the tabs
located in the back to plug into jaws.
This device to be used while meter
bypass jumpers are in place (1MMBPJ).

1MMACP

Used for 125A stacks. Fits bottom
socket only. Kit replaces existing meter
cover preventing access to meter socket.
Includes hasp for seal.

1MMBC125B

Used on 200A stacks. Fits bottom
socket only. Kit replaces existing meter
cover preventing access to meter socket.
Includes hasp for seal.

1MMBC200B

5
5

Lexan Blank Cover

5
5
5
Blank meter
socket cover

5
5
5
5
5

Catalog
Number

Wall Mounting Rail

Wall mounting rail

Rails are 4 feet (1.2m) in length.
Bolted on wall for stacks, packs
and mains to be hung.

1MMWB

Bussed Spacer

Bussed spacer

Bussed spacer 1200A 4-inch
(101.6 mm). Required when stacks
are mounted on right-hand side in
EUSERC areas. (copper)

3MMBSK 2

Bus duct riser/
meter center
connection

Available in 400, 600, 800A
main fusible units only.
Contact product line for details.

—

5
5
5
5
5

Notes
1 WCG8HB only applies to meter packs built prior to 1998. Current meter packs use 1MMBPH.
2 Must be used when mounting MCB main next to an MTB main or another MCB main device.

5
V1-T5-136

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Metering Products
Group Metering

5.10

Accessories for 1MP, 1MM and 3MM Modular Metering Stacks, continued

Indoor Corner Elbow

Application

Indoor corner elbow
(copper)

12-inch (304.8 mm) indoor corner
elbow, 1200A, three-phase, four-wire
for use with 1MM and 3MM only.
Do not use with 35MM, 37MM,
35SS or 37SS stacks.
12-inch corner elbow not EUSERC approved.

3MMEB12

Indoor corner elbow
(copper)

16-inch (406.4 mm) indoor corner
elbow, 1200A, three-phase, four-wire
for use with 1MM, 3MM, 35MM,
37MM, 35SS and 37SS.

3MMEB16

Barrier

Barrier for individual sockets

1MMBK

Meter jumper
and cover

Combination meter jumper and
cover (200A maximum).
Used to jumper line and load
jaws as well as cover meter
socket preventing exposure to
current carrying parts.

1MMJCK

125A two-pole lug block assembly.

BRSF125

Lug block
Standard Sealing Ring

Sealing ring

Top endwall

5

Catalog
Number

Description

5
5
5
5
5
5
5

Stainless steel screw type with brass screw

1MMSR1

Standard (included with packs and stacks) 1

1MMSR2

Stainless steel screw type with cast zinc screw

1MMSR4

Aluminum screw type with locking provisions

1MMSR5

125A, NEMA 1 top end wall with
knockouts for 1MM, 3MM meter stacks

MM12N1WLK

200A, NEMA 1 top end wall
for 1MM, 3MM meter stacks

MM20N1WLK

5
5
5
5
5
5
5

Note
1 Aluminum Snap Type.

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-137

5.10
5

Metering Products
Group Metering

Renewal Parts

5

1MP, 1MM and 3MM Replacement Parts

5

Description

Application

Ringless cover
(can install this to go
from ring to ringless)

Installed on 125A socket
for ringless security

1MMRC125

Installed on 200A socket
for ringless security

1MMRC200

For use with top position of 125A,
two- and three-position,1MM and 3MM stacks
and two-, five- and six-position 1MP packs

1MMRC125T

Top-position two position IMP

1MMRC200T

Installed on 125A socket
for ring security

1MMCP1

Installed on 200A socket
for ring security

1MMCP2

5

Top socket ring cover 125A

1MMCP1T

5

Top socket ring cover 200A

1MMCP2T

125A cover

1MMBC1

200A cover

1MMBC2

125 and 200A

1MMMS

Flat—left side

47-24139A

Bump—right side

47-28172-2A

5

Ringless Cover

5
5
5
5
5

Ring Cover

Ring cover

5

5

Tenent Breaker Cover

5

Tenant breaker
hinged cover

5
5
5

Meter Socket

Meter socket 1

Catalog
Number

5
5
5

Busbar end cap

5

Main circuit breaker
cover kit (black)

5

49-7060

5
5

Notes
1 Meter Packs 1MP2122RRL and 1MP2122RRLB use different meter sockets.
See Renewal Parts listing RP.32A.01A.T.E for details.

5

See RP00501001E for a complete Renewal Parts listing.

5
5
5
5
5
V1-T5-138

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Metering Products
Group Metering

5.10

Accessories for 35MM and 37MM Modular Metering Stacks

5

Catalog
Number

Description

Application

Wall mounting rail

Rails are 4 feet (1.2m) in length. Bolted on wall for stacks,
packs and mains to be hung.

1MMWB

5

Indoor corner elbow (copper)

16-inch (406.4 mm) indoor corner elbow, 1200A, three-phase,
four-wire for use with 1MM, 3MM, 35MM, 37MM, 35SS and 37SS.

3MMEB16

5

Handle
insulator

Each meter block includes a lever bypass. This kit includes the sleeve
which slides onto the lever handle.

37MMHC

5

Needed when using barrel lock security.

37MMBLK

5

Barrel Lock Bracket Kit Barrel lock bracket kit

5
5
5
Totalizing Jumper Kit

Totalizing jumper kit

Used if one socket is to meter two tenant feeds. When ordering jumper
kit, should also order a plastic cover plate (1MMPCP + IMMJCK) preventing
access to live parts on unused socket.

5

37MMTJK

5
5

Type EHD and CV
Breaker Retrofit
Mounting Kit

Type EHD and CV breaker retrofit mounting kit

Retrofit mounting hardware for installation of Type EHD and CV breakers in
35MM, 37SS, 37MM and 37SS meter stacks manufactured prior to February 2013.
Order one kit per breaker.

5

37MMRCBK

5
5

Type CV Breaker
Mounting Kit

Type CV breaker mounting kit

Replacement Type CV breaker mounting hardware kit. Used in 200A
1MP/1MM/3MM modular metering stacks at 42, 65 and 100 kAIC.

5

1MMCBK

5
5
5

Blank Cover Kit

Blank cover kit

Kit replaces meter cover preventing access to socket.

37MMCK 1

5
5

37MMCKA 2

5
Three-Phase to
Single-Phase
Conversion Kit

Barrier

Barrier for individual sockets

37MMBK

Three-Phase to single-phase conversion kit

This kit will convert one three-phase meter socket (37MM devices) to a
single-phase socket. Only needed if phasing A-C or C-B. If single-phase socket
is to be phased A-B, kit is not required for field conversion.
(Must use three-phase breaker.)

37MM1CK

5
5
5
5
5

Bus duct riser/meter center connection

Available in 400, 600, 800A
Main fusible units and 400, 600, 800, 1000,
1200 main circuit breaker. Contact product line for details.

—

Anti-inversion clip

This clip should be inserted into upper right hand jaw of a 320A meter socket. The
purpose is prevent a 200A meter from being inserted into a 320A meter socket.

37MMINVCLIP

5
5
5

Notes
1 For all units made 10/2002 and earlier.
2 For all units made after 11/2002.

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

5
V1-T5-139

5.10
5

Metering Products
Group Metering

Renewal Parts

5

35MM and 37MM Modular Metering Stacks

5

Description

Application

35MM replacement
meter socket

To replace meter socket
with lever bypass and jaw release.

MSLMSA1

37MM replacement
meter socket

To replace meter socket
with lever bypass and jaw release.

MSLMSA2

35SS replacement
meter socket

To replace meter socket with
test bypass disconnect feature

MSTMSA1

37SS replacement
meter socket

To replace meter socket with
test bypass disconnect feature

MSTMSA2

5

Safety socket
meter cover assembly

To replace ring type cover over the
meter prior to 7/1/02.

MSTMCVR1

5

Safety socket
meter cover assembly

To replace ring type cover over the
meter after 7/1/02

MSTMCVR1E

35MM and 37MM
meter cover assembly

Prior to 12/1/02

37MMSK

After 12/1/02

37MMSK1

To replace ringless cover over the meter.
Includes New Jersey latch requirement.

37MMSKNJ

5

35MM Replacement
Meter Socket

5

Catalog
Number

5
5
5
5

37SS Replacement
Meter Socket

5
5
5

Meter Cover Assembly

5
5
5

Meter cover assembly
with NJ latch

5
5

Tenant breaker hinged cover

To replace cover over tenant breakers.

1MMBC2

Busbar end cap

Flat—left side

47-24139A

Bump—right side

47-28172-2A

Main circuit breaker cover/CIT (black)

5

49-7060

Note
See RP.32A.01.T.E for a complete Renewal Parts listing.

5
5
5
5
5
5
5
5
5
5
V1-T5-140

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

5.10

Metering Products
Group Metering

Technical Data and
Specifications

5

Phase Balancing
125 A STACKS

N

A

A

A

A

5

B

B

B

B

5

C

C

C

C

5

N

5

A

B

B

"Z" Shaped
Phase Connector

5

"Z" Shaped
Phase Connector

FACTORY 125 A A-B PHASING

5

FACTORY 200 A A-B PHASING

N

N

N

FIGURE B

5

A

A

A

A

5

B

B

B

B

5

C

C

C

5

C

C

"Barrel" Shaped
Phase Connector
FIELD 125 A A-C PHASING
Remove "Z" Phase Jumper from "B" Phase
Horizontal Bus
Replace with "Barrel" Phase Jumper from
kit 99-4184
Supplied with Meter Stack and attach to "C" Phase
Bus as shown.
Torque to 60 lb-in (6.78 N-M)
Retain "Z" Phase Jumper for future use.

FIGURE C

N
A

A

“Z” Shaped and “Barrel”
Shaped Phase Connector

5

"Barrel" Shaped
Phase Connector

"Barrel" Shaped
Phase Connector

16 Total Positions—use
(two) five-position and (two)
three-position stacks. Phase
balance (one) five-position
per Figure B (A-C phasing)
and (one) five-position per
Figure C (C-B phasing).

5

C

5

"Z" Shaped
Phase Connector
FACTORY 200 A A-C PHASING

5

Remove "Z" Phase Jumper from "B" Phase
Horizontal Bus
Reattached at "C" Phase Horizontal Bus as Shown.
Torque to 60 lb-in (6.78 N-M)

5
5

N

N

N

N

5

A

A

A

A

5

B

B

B

B

5

C

C

C

5

C

C

"Barrel" Shaped
Phase Connector

B

C

B

5

"Z" Shaped
Phase Connector

FIELD 125 A C-B PHASING
Remove "Barrel" Phase Jumper from "A" Phase
Horizontal Bus
Reattached at "C" Phase Horizontal Bus as shown.
Torque to 60 lb-in (6.78 N-M)

"Barrel" Shaped
Phase
Connector

5

N
A

Nine Total Positions—use
(three) three-position stacks
and phase one per Figure B
(A-C phasing) and one per
Figure C (C-B phasing).

"Z" Shaped
Phase
Connector

"Barrel" Shaped
Phase Connector

N

Examples:

19 Total Positions—where
four-position maximum
height is allowed by utility.
Use (one) four-position and
(five) three-position stacks.
Phase balance (two) threeposition stacks per Figure B
(A-C phasing) and (two)
three-position stacks per
Figure C (C-B phasing).

5

200 A STACKS

"Barrel" Shaped
Phase Connector

FIGURE A

Phase Balancing
All 3MM meter modules
come factory connected
to phase A and B, per
Figure A. When connected to
a 208Y/120 Vac three-phase,
four-wire system, field phase
balancing of two out of every
three stacks is required. One
of every three stacks should
be phased AC, per Figure B,
and one of every three stacks
should be phased CB, per
Figure C.

5

"Barrel" Shaped
Phase Connector

5

"Z" Shaped
Phase Connector

5

FACTORY 200 A C-B PHASING
Remove "Barrel" Phase Jumper from "A" Phase
Horizontal Bus
Reattached at "C" Phase Horizontal Bus as shown.
Torque to 60 lb-in (6.78 N-M)

5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-141

5.10
5
5
5
5
5
5
5
5
5
5

Metering Products
Group Metering

Series Combination
Short-Circuit Ratings
When main tenant breakers
are installed in Eaton’s
modular metering stack
per the table on Page
V1-T5-143, the branch
breakers installed in
downstream panel rated 10
kAIC or greater are protected
to the listed series AIC rating.
Refer to the downstream
panel marking for the proper
series combination shortcircuit ratings.

Series Combination
Short-Circuit Ratings
The Watt-Hour Meter is not
Included in the Short-Circuit
Current Rating (Per UL 67).
Downstream Panel
(Type CH or BR)
Main
Tenant
Breaker
Main Modular
Service Metering
Module
Stack

Load Side
Breakers

Replacement or additional
breakers shall be of the same
manufacture and type, and
shall have an interrupting
rating equal to or greater than
the interrupting rating of any
main tenant breaker installed.

5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
V1-T5-142

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Metering Products
Group Metering

5.10

Series Combination Short-Circuit Ratings—240 Vac

5

Main Module Overcurrent Device
Breaker Type or Class Fuse

System
AIC Rating
120/240 Vac
Maximum

Meter Module
Tenant Feeder Breaker
Type 1MM, 3MM, 35MM,
37MM, 35SS, 37SS
or Loadcenter Main Breaker

Tenant Feeder
Breaker ShortCircuit Rating

Loadcenter Branch Breaker
(Single-, Two- or Three-Pole)

None

10,000

None

—

BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI

Without main disconnect.
Cable tap box
Type 1MTB_, 3MTB_

10,000

BR_, CC_, BW_, CCV_

10,000

22,000

BRH_

22,000

25,000

CSR_, CHH_H2, CCVH_

25,000

42,000

BRHH_, CHH_H4, CVS_

42,000

65,000

CV_, KD_, HKD_

65,000

5
5
5
5

100,000

CHH_, CVH_, KDC_

100,000

Main switch module
Type 1MFS_, 3MFS_
with Class T fuse,
400A maximum

42,000

BRH_

22,000

CH, CHT, CH3, CH-GFCI

Main switch module
Type 1MFS_, 3MFS_
with Class T fuse,
600A maximum

100,000

BRH_

22,000

BD, BR, BRD, BQ, BQC, GFCB

Main switch module
Type 1MFS_, 3MFS_
with Class T fuse,
1200A maximum

10,000

BR_, CC_, BW_, CCV_

10,000

BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI

22,000

BRH_

22,000

25,000

CSR_, CHH_H2, CCVH_

25,000

42,000

BRHH_, CHH_H4, CVS_

42,000

65,000

CV_, KD_, HKD_

65,000

100,000

CHH_, CVH_, KDC_

100,000

Main switch module
Type 1MFS_, 3MFS_
with Class T fuse,
1200A maximum

100,000

BRHH_

42,000

BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI

Main switch module
Type 1BPS_, 3BPS_
with Class L fuse,
1200–2000A

10,000

BR_, CC_, BW_, CCV_

10,000

BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI

22,000

BRH_

22,000

25,000

CSR_, CHH_H2, CCVH_

25,000

42,000

BRHH_, CHH_H4, CVS_

42,000

65,000

CV_, KD_, HKD_

65,000

100,000

CHH, CVH_, KDC_

100,000

10,000

BR_, CC_, BW_, CCV_

10,000

22,000

BRH_

22,000

25,000

CSR_, CHH_H2, CCVH_

25,000

Main breaker module
Type 1MCB_, 3MCB_ with
KD, HKD (400A maximum)
LD, HLD (600A maximum)
MDL, HMDL (800A maximum)
ND, NGS, HND, NGH (1200A maximum)
RD, RGH (2000A maximum)

5

5
5
5
5
5
5
5
5
5

42,000

BRHH_, CHH_H4, CVS_

42,000

65,000

CV_, KD_, HKD_

65,000

100,000 1

CHH_, CVH_, KDC_

100,000

5
5
5
5

BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI

5
5
5
5

Note
1 100,000A rating with 100,000A rated main.

5
5
5
5
5
5
5
Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-143

5.10

Metering Products
Group Metering

5

1MP 125A Meter Module
This All-in-One Meter Module is UL listed for the short-circuit
rating at 240 Vac maximum in rms symmetrical amperes per
table below.

5

1MP 125A Meter Module

5

Tenant Breaker
Catalog Number
Two-Pole

5

5
5
5
5
5
5
5

1MP 200A Meter Module
Tenant Breaker
Catalog Number
Two- or Three-Pole

Maximum
Ampere Rating

UL Listed Series
Short-Circuit
Rating

Maximum
Ampere Rating

UL Listed Series
Short-Circuit
Rating

CVH_XMM

200

100 kAIC

BRHH_____

125

42 kAIC

CV_XMM

200

65 kAIC

BRH_____

125

22 kAIC

CVS_XMM

200

42 kAIC

BR_____

125

10 kAIC

CCVH_XMM

200

25 kAIC

CCV_X

200

10 kAIC

When Type BRHH or BRH tenant breakers are installed in this
meter module, then Eaton’s breakers rated 10 kAIC or greater
installed on the load side of this meter module may be protected
for short circuits up to 22 kAIC with Type BRH breakers or
42 kAIC with Type BRHH breakers.

When Type CV tenant breakers are installed in this meter
module, then breakers rated 10 kAIC or greater installed on
the load side of this meter module may be protected for short
circuits up to 100 kAIC.

See load side breaker panel marking for proper short-circuit
current rating.

See load side breaker panel marking for proper short-circuit
current rating.

1MP 125A Meter Module

1MP 200A Meter Module

The Watt-Hour Meter is not
Included in the Short-Circuit
Current Rating (Per UL 67).

5
5
5

This All-in-One Meter Module is UL listed for the short-circuit
rating at 240 Vac maximum in rms symmetrical amperes per
table below.

All-in-One
Meter
Module

5

Downstream Panel
(Type CH or BR)
Tenant
Breaker

5

The Watt-Hour Meter is not
Included in the Short-Circuit
Current Rating (Per UL 67).

All-in-One
Meter
Module

Downstream Panel
(Type CH or BR)
Tenant
Breaker

Load Side
Breakers

5

1MP 200A Meter Module

5

Note: The ratings for both 125 and 200A tenant positions apply to
both Type BR and CH loadcenters and 10 kAIC branch breakers.

5
5
5
5
5
5
5
5
5
5
5
5
V1-T5-144

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Load Side
Breakers

5.10

Metering Products
Group Metering

General
When tenant breakers are installed in Eaton’s metering
modules per the short-circuit current ratings below, the
branch breakers installed in downstream panel rated 10 kAIC or
greater are protected to the listed series AIC rating. Refer to the
downstream panel marking for the proper series combination
short-circuit ratings. These ratings apply to both loadcenter
Types BR and CH.
The short-circuit rating is limited to the lowest interrupting
rating of any tenant breaker installed or to the lowest marked
interrupting rating of the main switch, main breaker or main
lug modules.
Replacement or additional breakers shall be of the same type
and manufacturer, and shall have an interrupting rating equal
to or greater than the interrupting rating of any tenant breaker
presently installed in the meter module.
1MM, 3MM 125A Meter Module
When used with main switch, main breaker or main lug
modules, this meter module is UL listed for the short-circuit
rating at 240 Vac maximum in rms symmetrical amperes per
table below.
1MM, 3MM 125A Meter Module
Tenant Breaker
Catalog Number
Two-Pole

Amperes
Maximum

UL Listed Series
Short-Circuit Rating

BRHH_____

125

42 kAIC

BRH_____

125

22 kAIC

BR_____

125

10 kAIC

When Type BRHH or BRH tenant breakers are installed in this
meter module, then breakers rated 10 kAIC or greater installed
on the load side of this meter module may be protected for short
circuits up to 22 kAIC with Type BRH breakers or 42 kAIC with
Type BRHH breakers.

1MM, 3MM, 200A Meter Modules; 35MM, 37MM, 35SS and 37SS 225A
Meter Modules
When used with main switch, main breaker or main lug
modules, these meter modules are UL listed for the short-circuit
rating at 240 Vac maximum in rms symmetrical amperes per
table below.

5

1MM, 3MM, 200A Meter Modules; 35MM, 37MM, 35SS and
37SS 225A Meter Modules

5

Amperes Maximum
Tenant Breaker
Catalog Number
Two- or Three-Pole

1MM
3MM
200A

35MM, 37MM,
35SS, 37SS
UL Listed Series
225A
Short-Circuit Rating

CVH_XMM

200

225

100 kAIC

CV_XMM

200

225

65 kAIC

CVS_XMM

200

225

42 kAIC

CCVH_X

200

225

25 kAIC

CCV_X

200

225

10 kAIC

CC_X

200

225

10 kAIC

5

5

1MM, 3MM, 200A Meter Modules; 35MM, 37MM, 35SS and
37SS 225A Meter Modules

5
5
5
5
5
5

The Watt-Hour Meter is not
Included in the Short-Circuit
Current Rating (Per UL 67).

5

Downstream Panel
(Type CH or BR)

5

Main
Tenant
Breaker

5
5

Load Side
Breakers

5

The Watt-Hour Meter is not
Included in the Short-Circuit
Current Rating (Per UL 67).

5

Downstream Panel
(Type CH or BR)

5

Main
Tenant
Breaker
Main Modular
Service Metering
Module
Stack

5

5

See load side breaker panel marking for proper short-circuit
current rating.

Main Modular
Service Metering
Module
Stack

1MM, 3MM 125A Meter Module

5

5

When Type CV tenant breakers are installed in these meter
modules, then Eaton’s breakers rated 10 kAIC or greater
installed on the load side of these meter modules may be
protected for short circuits up to 100 kAIC.

See load side breaker panel marking for proper short-circuit
current rating.

5

5
5

Load Side
Breakers

5
5
5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-145

5.10
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5

Metering Products
Group Metering

Ratings
A. The assembly shall be
rated to withstand
mechanical forces
exerted during shortcircuit conditions when
connected directly to
a power source having
available fault current
[22,000] [42,000]
[65,000] [100,000]
amperes symmetrical
at rated voltage.
Construction
A. The entire assembly shall
be front accessible and
shall include [main lugs]
[a main disconnect
device].
B. Tenant disconnects
shall be wired for cold
sequence and shall be
molded case circuit
breakers.
C. The meter sockets shall
be (ring-) (ringless-) type
rated (125A) (200A) (as
shown on the plans)
and a bypass (shall be)
(shall not be) required.
If required, the bypass
shall be a (slider-) (horn-)
(lever-) (disconnect block-)
type. The meter sockets
and associated branch
protective device
positions shall be
completely prewired
and shipped ready for
installation of the meters
and tenant main breakers.
Meter sockets shall
include covers with
sealing positions.
Bus
A. All busbars shall be [tinplated aluminum or
copper]. Main horizontal
busbars shall be
mounted with all three
phases arranged in the
same vertical plane. Bus
sizing shall be based on
UL standard temperature
rise criteria for multiple
metering equipment.
B. Provide a full capacity
neutral bus where a
neutral bus is indicated
on the drawings.

C. All hardware used for
busbar connections shall
be high-tensile strength,
zinc-plated. Provide
Belleville-type spring
washers for all bus joints.
Wiring/Terminations
A. [Mechanical-type
terminals] [Crimp-type
termination provisions]
shall be provided for all
line terminations suitable
for copper or aluminum
cable and rated at 75ºC.
B. Lugs shall be provided in
the incoming line section
for connection of the main
grounding conductor.
Main Circuit Protective Devices
A. Main protective devices
shall be [molded case
circuit breakers] [bolted
pressure switches] [quickmake/quick-break fusible
switches].
Molded Case Circuit Breakers
A. [Main] [Feeder] [All]
protective devices shall
be molded case circuit
breakers with inverse
time and instantaneous
tripping characteristics.
B. Circuit breakers shall be
operated by a toggle-type
handle and shall have a
quick-make/quick-break
over-center switching
mechanism that is
mechanically trip-free.
Automatic tripping of the
breaker shall be clearly
indicated by the handle
position. Contacts shall
be nonwelding silver
alloy and arc extension
shall be accomplished by
means of DE-ION® arc
chutes.
C. Circuit breakers shall
have a minimum
symmetrical interrupting
capacity as indicated on
the drawings.

D. Circuit breakers [250-]
[400-] [600-] [1200-]
ampere frame and below
shall be manufactured
by Eaton with thermalmagnetic or electronic
trip units having
inverse time-current
characteristics.
E. Circuit breakers shall be
UL listed for series
application.
Bolted Pressure Switches
A. Main protective devices
shall be bolted pressure
contact type and shall be
UL listed.
B. Fusible switches shall be
furnished with Class L
fuse clips. Switch
contact interrupting
capacity shall be 12 times
the continuous rating
of the switch.
C. Fuse access door s
hall be mechanically
interlocked with the
operating handle and
shall have provisions for
padlocking the switch in
the OPEN position.
D. The switch shall use a
stored energy deadfront
operating mechanism
compressed and
released by the operating
handle, to provide quick
positive switching action,
independent of the
operating handle.
E. Switches shall be
manually operated.
Quick-Make/Quick-Break
Fusible Switches
A. Fusible switches 30A
through 1200A frames
shall be furnished with
300V Class T-type fuse
clips unless otherwise
scheduled.
B. Switches shall
incorporate safety cover
interlocks to prevent
opening the cover with
the switch in the ON
position.
C. Provide defeater for
authorized personnel.

5
V1-T5-146

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

D. Handles shall have
provisions for padlocking
and shall clearly indicate
the ON or OFF position.
E. Front cover doors shall
be padlockable in the
CLOSED position.
F. Main protective devices
shall be quick-make/
quick-break fusible
switches as manufactured
by Eaton.
Tenant Utility Metering
A. For EUSERC serviced
areas, meter centers
shall incorporate
metering sections with
tenant feeder circuits
using ring-type meter
sockets rated [125] [200]
amperes to meet local
utility and/or customer
requirements.
B. The self-contained meter
sockets shall include a
test bypass/disconnect
block per EUSERC
requirements,
– OR–
A. For non-EUSERC
serviced areas, meter
centers shall incorporate
metering sections with
tenant feeder circuits
using [ring-] [ringless-]
type meter sockets
rated [125] [200] [320]
amperes to meet local
utility or customer
requirements. Provide
meter sockets with
individual covers having
sealing provisions.
B. Meter sockets shall
have manual bypass and
optional internal barriers.
Enclosures
A. NEMA 1 Enclosure
– OR–
A. Outdoor NEMA 3R
Surface-Mounted
Enclosure
Finish
A. Boxes and trims shall be
bonderized and finished
with ANSI 61 light gray
enamel.

5.10

Metering Products
Group Metering

Dimensions

5

Approximate Dimensions in Inches (mm)

5

General Layout

5

Minimum and maximum height of single-phase and three-phase
meter sockets above typical ground level.
1MM/3MM
200 A

1MM/3MM
200 A

1MM/3MM
125 A

35MM/37MM
225 A Maximum

35MM/37MM
225 A Maximum

35MM/37MM
225 A Maximum

37MM
400 A

35MM/37MM

5

13.50
(342.9)

13.50
(342.9)

12.25
(311.2)

19.25
(488.8)

18.25
(463.6)

18.25
(463.6)

18.25
(463.6)

18.25
(463.6)

5
5
5
5
5

Wall Hanger Screws
C
L

5

34.25
(870.0)

5
5

Main Device a

5

b

30.14
(765.6)
13.38
(339.7)

31.88
(809.6)

26.00
(660.4)
68.25
(1733.6)

71.00
(1803.4)

30.00
(762.0)

30.00
(762.0)
72.00
(1828.8)

58.00
(1473.2)

44.00
(1117.6)

44.00
(1117.6)

58.00
(1473.2)

44.00
(1117.6)
31.00
(787.4)

5
5

Typical Height
Above Ground
or Floor Level

5
5

Mounting Features

5
5
5
5
5
5

Mounting Features

5

A standard mounting rail and
factory-installed swing away
feet, speed up and simplify
installation.

5
5

Notes
1 Not a constant value. Dimension changes depending on main device chosen. See Page V1-T5-110 for specific dimensions.
2 Residential device.

5
5
5
5

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T5-147

Power Pedestals
Power Pedestals

6.1

Introduction
Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Application Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Optional Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6.2

Marina Power and Lighting

Temporary Power/RV Park
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Application Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Features and Benefits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Standards and Certifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Renewal Parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Surface Units. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pedestal Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Construction Site and RV Parks

6.3

6.5

V1-T6-21
V1-T6-21
V1-T6-22
V1-T6-22
V1-T6-23
V1-T6-24

RV Park Hook-Ups
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Powerhouse Power Pedestal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Powerhouse—Stainless Steel (SS) Power Pedestal . . . . . . . . . . . . . .
Newport Camp Mate Power Pedestal . . . . . . . . . . . . . . . . . . . . . . . . .
Park Light Power Pedestal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Firehouse. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters . . . . . . . . . . . . . . . . . . . . . . . .
Distribution Equipment—Ground Fault Monitor . . . . . . . . . . . . . . . . .
Distribution Equipment—Substations . . . . . . . . . . . . . . . . . . . . . . . . .
Distribution Equipment—Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Distribution Equipment—Transformers . . . . . . . . . . . . . . . . . . . . . . . .

Mobile Home Panels

V1-T6-3
V1-T6-3
V1-T6-4
V1-T6-4
V1-T6-5
V1-T6-6
V1-T6-7
V1-T6-7
V1-T6-8
V1-T6-10
V1-T6-10
V1-T6-10
V1-T6-13
V1-T6-16
V1-T6-16
V1-T6-16
V1-T6-18

Mobile Home Panels
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6.4

V1-T6-2
V1-T6-2
V1-T6-2

6
6
6
6
6
6
6
6
6
6
6
6
6
6

V1-T6-51
V1-T6-54
V1-T6-58
V1-T6-62
V1-T6-65
V1-T6-69
V1-T6-73
V1-T6-79
V1-T6-80
V1-T6-81
V1-T6-82
V1-T6-83
V1-T6-86
V1-T6-89
V1-T6-90

6

Don’t Give Up!
If you don’t find the product you want in this catalog, try the Flex Center at 1-800-330-6479.

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

6

V1-T6-28
V1-T6-30
V1-T6-33
V1-T6-36
V1-T6-39
V1-T6-42
V1-T6-44
V1-T6-45
V1-T6-46
V1-T6-49
V1-T6-50

Marina Power and Lighting Equipment
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hatteras Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Firehouse. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mariner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters . . . . . . . . . . . . . . . . . . . . . . . .
Distribution Equipment—Ground Fault Monitor . . . . . . . . . . . . . . . . .
Distribution Equipment—Mega Yacht Powerpoint . . . . . . . . . . . . . . .
Distribution Equipment—Substations . . . . . . . . . . . . . . . . . . . . . . . . .
Distribution Equipment—Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Distribution Equipment—Transformers . . . . . . . . . . . . . . . . . . . . . . . .

6

V1-T6-1

6
6
6
6
6
6
6
6
6
6
6
6
6

6.1
6

Power Pedestals
Introduction

Contents

Power Pedestals

Description

6

Introduction

6
6
6
6
6
6
6
6
6
6
6
6
6
6

Product Description

Application Description

A power pedestal is a device
designed for outdoor service
to meet temporary power
requirements at construction
sites, marinas, recreational
vehicle (RV parks, marinas
and mobile home parks).
Power pedestals provide a
safe and reliable means for
users to access electricity
at such locations.

Construction Site and
RV Parks
Power outlet panels on
construction sites and in
RV parks provide a safe and
reliable means for users to
access electricity. A wide
range of products are available
with multiple features and
enclosure material options.

6

Optional Features
Mobile Home Panels
Eaton’s versatile mobile home
panels have a user-friendly
design that allows for a faster,
cleaner installation. Mobile
home panels are designed for
service entrance distribution,
and include a meter and
distribution section with
breaker and receptacle
configuration options.

●

●
●
●
●

●
●

●

6
6

●

6
6
Mobile Home Panels

6

Marina Power and Lighting

6

Construction Site and RV Parks

6
6

Park lighting and marina
pedestals offer robust
enclosure options with
premium features to enhance
user convenience at marinas
and campgrounds.

6
6
6
6
6

Marina Power and Lighting
V1-T6-2

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Product can ship from the
factory completely
assembled and prewired
External light
TV and telephone jacks
Ground fault monitors
Digital electronic
kilowatthour meters
Water faucet
Available GFI (ground fault
interrupter) protection
Weatherproof engineered
resin enclosure (will never
rust or deteriorate)
Stainless steel to meet
and exceed all applicable
codes, and withstand
harsh inland and coastal
environments

Power Pedestals
Temporary Power/RV Park

6.2

Contents

Power Outlet Panels

Description
Product Overview . . . . . . . . . . . . . . . . . . . . . . . . .
Application Description . . . . . . . . . . . . . . . . . .
Features and Benefits . . . . . . . . . . . . . . . . . . .
Standards and Certifications . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
Renewal Parts . . . . . . . . . . . . . . . . . . . . . . . . .
Surface Units. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pedestal Units . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page
V1-T6-3
V1-T6-4
V1-T6-4
V1-T6-5
V1-T6-6
V1-T6-7
V1-T6-7
V1-T6-8
V1-T6-10
V1-T6-16

6
6
6
6
6
6
6
6
6
6
6

Product Overview
A power outlet panel (or POP)
is a device designed for
outdoor service to meet
temporary power
requirements at construction
sites and RV parks. POPs
provide a safe and reliable
means for users to access
electricity at such locations.

6

Product Description
Power outlet panels shall be
designed for outdoor service
to meet temporary power
outlet requirements at
construction sites and provide
high quality, economical
power to individual sites
at RV parks. POPs shall be
provided with means to bond
the neutral for temporary
service entrance applications.
RV panels shall have a factoryinstalled insulated neutral bar.
Receptacles and
Circuit Protection
Circuit protection shall be
Eaton’s UL listed full-size
Type BR or half-size Type BD
circuit breakers. The
receptacles shall be NEMA
commercial/industrial grade
devices. Ground fault
protection (GFCB) shall be
provided at the 20A duplex
NEMA 5-20R receptacle or
20A single-pole circuit
breaker when required.
Ground fault protection shall
be provided at the circuit
breaker for receptacles above
20A when required.

Construction
The power outlet panel
pedestal shall be of deadfront
design and constructed of
heavy gauge, 100 percent
galvanized steel. Baked-on
polyester powder coating
shall be used for excellent
mechanical strength, plus
resistance to chalking caused
by the sun’s ultraviolet rays.
The power outlet panel
surface and pedestal units
shall have NEMA Type 3R
rainproof enclosures.

6
6
6
6
6
6
6

Ease of Installation
Panels shall ship from
the factory completely
assembled, prewired with
100 percent copper wire, and
tested in accordance with
UL Standard 231. The door
shall swing up and open for
user convenience and ease
of access to breakers and
receptacles. When required,
a means for securing the
door in the open position
shall be provided. Panels
shall be bottom fed through
knockouts in endwall or top
fed using a bolt-on raintight
hub. Knockouts shall range
from 1/2-inch (12.7 mm) to
1-1/2 inches (38.1 mm).
Grounding provisions
(#4–14 Cu/Al) shall be
provided on all panels.

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

6
6
6
6
6
6
6
6
6
6
6
V1-T6-3

6.2
6
6
6
6
6
6
6
6
6

Power Pedestals
Temporary Power/RV Park

Application Description
POPs are also sometimes
called temporary power
panels, temporary site
service equipment or
RV panels.
Construction Site Application
When POPs are used at a
construction site, they are
installed on a temporary basis
until permanent electrical
power is available at the
building. The most common
reason for needing a POP
at a construction site is to
provide a power source for
the contractor’s tools.

Features and Benefits
RV Park Applications
When POPs are used at an
RV park, they are installed
for more permanent use
and serve the purpose of
providing power to the
recreational vehicles. Many
RV parks now supply
customers with amenities
such as lighted POPs with TV
and telephone jacks.

6

RV Park Application

Construction Site Application

6
6
6
6
6
6
6
6
6

●

●

6
6

●

●

6
6

●

Service Applications
Suitable for use as temporary
Service Entrance Equipment,
temporary power service
equipment and recreational
vehicle site supply.

Designed for outdoor
service to meet power
outlet requirements
Receptacles conform
to NEMA and/or ANSI
configurations as specified
by the National Electrical
Code® (NEC)
Includes a factory-installed
insulated neutral bar with
provisions for bonding
when used for temporary
service entrance
applications
125A rated meter socket
Temporary power and RV
park POPs are CSA listed.
Compact POP and single
receptacle devices are not
CSA listed

Designed for Easy Installation
and Protection
●
Panels come from the
factory completely
assembled, prewired with
100 percent copper wire
and tested...ready for easy
installation
●
Door swings up and open
for user convenience and
ease of access to breakers
and receptacles
●
Panels can be bottom fed
through knockouts in the
endwall or top fed using a
bolt-on raintight hub
●
Two-piece deadfront cover
allows field wiring without
interfering with factory
wiring
●
Lower deadfront cover
permits easy field wiring to
circuit protective devices
●
Available GFI (ground fault
interrupter) single- and
two-pole protection
through 50A

6
6
6
6
6
6
6
V1-T6-4

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Power Pedestals
Temporary Power/RV Park

Two Styles to Meet Your
Power Outlet Needs
●
Surface mount: User
mounts unit to a post
●
Pedestal mount:
User mounts with an
underground pedestal
extension or pad-mounting
bracket. (Underground
pedestal extension and
pad-mounting bracket are
sold separately. See
accessories Page V1-T6-7
for part numbers and
options)

6.2

Surface Units

6
NEMA 3R construction for
rainproof installation

6

100 percent galvanized
steel with baked-on
polyester powder coating

Utility grade metering available
for construction site or RV park
applications

6

Three-point mounting

Door swings up when opening
and allows cords to remain
connected when closed.

One-piece case back for
metered and unmetered
panels
Lighted option for site
location and nighttime
panel operations

6
6
6

Removable upper deadfront
cover for easy incoming wire
connections to breaker terminals

6
6

GFI circuit breakers
available through 50A
Unique steel barrier
prevents unauthorized
operation of breakers
when door is closed
and padlocked

• Metered units available with
meter on top or on bottom

Lower deadfront cover
can be removed for easy
routing of incoming wires or
receptacle changeouts

6

Padlock provisions to prevent
unauthorized entry

6

6
6

• Units are factory wired
and assembled

6

Compact Design Available in Certain
Configurations for Added Convenience

Pedestal Units

6

Standards and Certifications
UL Standard 231
UL File Number E163588
Receptacles conform to
NEMA and/or ANSI
configurations as specified
by the NEC.
●

Standard Compliance
All power outlet panels for
temporary construction site
power and RV (recreational
vehicle) application shall be
UL listed for the U.S. per UL
Standard 231, File E163588.
Receptacles shall conform
to NEMA and/or ANSI
configurations as specified
by the National Electrical
Code (NEC).

6

NEMA 3R construction for
rainproof installation

●

100 percent galvanized
steel with baked-on
polyester powder coating

6

Utility grade metering
available for construction
site or RV park applications

6
6
6

Door swings up when
opening and allows
cords to remain connected
when closed
GFI circuit breakers
(single- and two-pole)
available through 50A

One-piece case back for
metered and unmetered
panels

Loop-feed lug assembly
with 350 kcmil lugs
included as standard

6
6

Removable upper deadfront cover for
easy incoming wire connections to
breaker terminals

6

Unique steel barrier prevents
unauthorized operation of breakers
when door is closed and padlocked

6
6

Lower deadfront cover can be
removed for easy routing of
incoming wires or receptacle
changeouts

6
6

Padlock provisions to prevent
unauthorized entry

6

Pedestal extension available
for underground services

6

Pad-mounted bracket
option also available

6

• Units are factory wired
and assembled

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

6
V1-T6-5

6.2
6

Power Pedestals
Temporary Power/RV Park

Catalog Number Selection

CH M 1 N 7 N 4 N P X L TZ U

6
6

Feed

Eaton’s
Cutler-Hammer®
Series

6
6

U=
Bottom fed
Blank =Top fed

Metering Type
U = Unmetered
M = Metered-ring
R = Metered-ringless

6
6

Pedestal Extension
Receptacle Type
Center Position 1
See “Receptacle Type
Left Position” for
code selection

Receptacle Type
Left Position 1

6

1 = NEMA 14-50R
3 = NEMA 14-30R
4 = NEMA TT-30R
5 = NEMA 6-20R2
6 = NEMA 5-20R2
7 = NEMA 5-20R2GFI
8 = NEMA 5-20R2GFI 2
9 = NEMA 5-20R2GFI 3

6
6
6

A=
B=
C=
D=
E=
F=
H=
J=
Blank =

NEMA L14-50R
NEMA L6-50R
NEMA L5-50R
NEMA L14-30R
NEMA L6-30R
NEMA L5-30R
NEMA L6-20R
NEMA L5-20R
No receptacle

TZ= Factory installed
pedestal extension
with lay-in
ground lug

Receptacle Type
Right Position 1
See “Receptacle Type
Left Position” for
code selection

Lighting
L = Lighted

Circuit Breaker Type
Position 2
N = Non-ground fault
G = Ground fault

Circuit Breaker Type
Position 3

Interior

N = Non-ground fault
G = Ground fault

X=
Six circuit
Blank = Standard
Four circuit

Circuit Breaker Type
Position 1

6

Mounting

N = Non-ground fault
G = Ground fault

S = Surface
P = Pedestal
B = Back-to-back
pedestal

6
6
6

Notes
1 For receptacle configurations, see table below.
2 Weather-resistant.
3 Weather-resistant/tamper resistant.

6

Receptacle Configuration

6

1

6
6

3

4

30A, 125V,
two-pole, three-wire, NEMA TT-30R

8

WR

20A, 125V,
two-pole, three-wire,
weather-resistant (WR), NEMA 5-20R2GFI

20A, 125V,
two-pole, three-wire, NEMA 5-20R2

9

WR

20A, 125V,
two-pole, three-wire, weather-resistant/
tamper-resistant (WR TR), NEMA 5-20R2GFI

TR

Single-pole, 20A breaker
7

20A, 125V,
two-pole, three-wire, NEMA 5-20R2GFI
Single-pole, 20A breaker

Twist-Lock and Custom Receptacle/Breaker Combinations
A

50A, 125/250V,
three-pole, three-wire, NEMA L14-50R

B

50A, 250V,
two-pole, three-wire, NEMA L6-50R

D

30A, 125/250V,
three-pole, four-wire, NEMA L14-30R

E

30A, 250V,
two-pole, three-wire, NEMA L6-30R

Two-pole, 50A breaker

6
6

6

Single-pole, 30A breaker

6
6

30A, 125/250V,
three-pole, four-wire, NEMA 14-30R

20A, 250V,
two-pole, three-wire, NEMA 6-20R2
Two-pole, 20A breaker

Two-pole, 30A breaker

6
6

5

Two-pole, 50A breaker

6
6

50A, 125/250V,
three-pole, four-wire, NEMA 14-50R

Two-pole, 30A breaker

Two-pole, 50A breaker
C

6

50A, 125V,
two-pole, three-wire, NEMA L5-50R
Single-pole, 50A breaker

H

Two-pole, 20A breaker
J

Two-pole, 30A breaker
F

30A, 125V,
two-pole, three-wire, NEMA L5-30R
Single-pole, 30A breaker

6
6
V1-T6-6

20A, 250V,
two-pole, three-wire, NEMA L6-20R

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

20A, 125V,
two-pole, three-wire, NEMA L5-20R
Single-pole, 20A breaker

Power Pedestals
Temporary Power/RV Park

6.2

Product Selection
When quoting or selecting
a power outlet panel, the
following questions should
be answered:
●

●

●

●

●

Unmetered, ring or
ringless style
Number and types of
receptacles (seven
standard and eight
twist-lock options)
Standard or ground
fault breakers
Surface, pedestal or
back-to-back mounting
Are any factory or field
options required?

Power Outlet Panel Receptacle
Configuration Rules

●

Four Receptacles/Unit
All receptacles must
be NEMA 5-20R2 or
NEMA 5-20R2GFI,
surface mount only.
Three Receptacles/Unit
●

●

One or more of the
receptacles must be
NEMA 6-20R2,
NEMA 5-20R2 or
NEMA 5-20R2GFI
NEMA 6-20R2,
NEMA 5-20R2, or
NEMA 5-20R2GFI must
go in the second position

6

If two receptacles consist
of types NEMA 14-50R,
NEMA 10-50R,
NEMA 14-30R or
NEMA 6-20R2 a six-circuit
interior must be added
●
Example:
CHUIN5N2NSX

6
6
6
6

Note: Configuration 1 and 2 were
chosen so a six-circuit interior
needs to be added (suffix X) to
the end of the catalog number.
Also, configuration 5 is in the
second position.

6
6
6

Two, One and Zero
Receptacles/Unit
Any configuration.

6
6

Accessories

6

Accessories

Underground Pedestal
Extension

Description

Catalog
Number

6

Underground pedestal extension

CHPEDEXT

Stainless steel underground pedestal extension

CHPEDEXTSS

6
6
6
6
6

Pad-Mount Bracket

Pad-mount bracket

6

CHPADEXT

6
Cable TV/Telephone
Bracket

Cable TV and telephone bracket

6

CHTELTV

6
6

DS Hub

Fluorescent Light Kit

Rainproof conduit hub 0.75 inch (19.1 mm)

DS075H1

Rainproof conduit hub 1.00 inch (25.4 mm)

DS100H1

Rainproof conduit hub 1.25 inch (31.8 mm)

DS125H1

Rainproof conduit hub 1.50 inch (38.1 mm)

DS150H1

6
6
6
6

Fluorescent Light Kit
Description

Catalog
Number

Converts power outlet panel to lighted unit, must also order CHOUTCVRL

CHFLGTKIT

6
6
6
6

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-7

6.2
6

Power Pedestals
Temporary Power/RV Park

Renewal Parts
Renewal Parts

6

Description

Catalog
Number

Circuit Breaker
(BR/GFCB)

See this volume, Tab 1, section 1.2

—

Meter Socket

Ring style replacement meter socket

CHPOPMSRING

Ringless style replacement meter socket

CHPOPMSRL

5th jaw kit

ARP00035CHJ

Horn bypass (one lug cap per kit; four kits required per device)

ARP00777CH

Bonding Strap and
Mounting Hardware

Bonding strap and mounting hardware

CHBONDST

Inner Lens

Inner lens for lighted power outlet panels

CHINLENS

Loop Feed
Lug Assembly

Loop feed lug assembly for single pedestal

CHLOOPFDP

Loop feed lug assembly for back-to-back pedestal

CHLOOPFDB

Lower Deadfront Cover

Blank lower deadfront cover

CHLDFCVR

6

Lower deadfront cover with duplex receptacle opening

CHLDFCVR1

Lower deadfront cover with duplex, duplex receptacle opening

CHLDFCVR2

6

Lower deadfront cover with duplex, duplex, duplex receptacle opening

CHLDFCVR3

Lower deadfront cover with rectangle receptacle opening

CHLDFCVR4

6

Lower deadfront cover with rectangle, rectangle receptacle opening

CHLDFCVR5

6

Lower deadfront cover with rectangle, rectangle, rectangle receptacle opening

CHLDFCVR6

Lower deadfront cover with duplex, rectangle receptacle opening

CHLDFCVR7

6

Lower deadfront cover with duplex, rectangle, duplex receptacle opening

CHLDFCVR8

Lower deadfront cover with rectangle, rectangle, duplex receptacle opening

CHLDFCVR9

6

Lower deadfront cover with round receptacle opening

CHLDFCVR10

Lower deadfront cover with round, round receptacle opening

CHLDFCVR11

Lower deadfront cover with round, duplex receptacle opening

CHLDFCVR12

6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

6
6
6
6
6
V1-T6-8

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Power Pedestals
Temporary Power/RV Park

6.2

Renewal Parts, continued

Upper Deadfront Cover

Description

Catalog
Number

Lower deadfront cover with round, duplex, duplex receptacle opening

CHLDFCVR13

Lower deadfront cover with round, duplex, round receptacle opening

CHLDFCVR14

Lower deadfront cover with round, rectangle receptacle opening

CHLDFCVR15

Lower deadfront cover with round, rectangle, rectangle receptacle opening

CHLDFCVR16

Lower deadfront cover with round, rectangle, round receptacle opening

CHLDFCVR17

Lower deadfront cover with round, rectangle, duplex receptacle opening

CHLDFCVR18

Upper deadfront cover with six breaker twistouts

CHUDFCVR

Upper deadfront cover with provisions for lighted option

CHUDFCVRL

6
6
6
6
6
6
6
6

Outer Door

Outer door

6

CHOUTCVR

6
6
6
6
Outer Door with Lens

Outer door with lens

CHOUTCVRL

6
6
6
6

Neutral Assemblies

6
Six-hole neutral assembly with 2/0 lug

CHNEUT

Seven-hole neutral assembly with 2/0 lug

CHNEUT1

Five-hole ground bar kit

GBK5

10-hole ground bar kit

GBK10

6
6
6

Replacement Meter Cover
Replacement meter cover—ring type

CHPOPRMC

Replacement meter cover—ringless

CHPOPRLMC

Replacement meter cover—ringless

CHPOPRLMCN

Replacement meter cover—ringless

CHPOPRLMCN2

6
6
6
6
6
6
6
6
6

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-9

6.2
6

Power Pedestals
Temporary Power/RV Park

Contents

Power Outlet Panels

Description

6

Page

Product Overview. . . . . . . . . . . . . . . . . . . . . . . . . .
Surface Units
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pedestal Units . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6
6

V1-T6-3
V1-T6-13
V1-T6-16

6
6
6
6
6
6
6

Surface Units

6

Product Overview

6
6
6
6
6

A power outlet panel (or POP)
is a device designed for
outdoor service to meet
temporary power
requirements at construction
sites and recreation vehicle
(RV) parks. POPs provide a
safe and reliable means for
users to access electricity
at such locations.

6

Product Selection
Power Outlet Panel Receptacle Configuration Rules
See Page V1-T6-8 for
Three Receptacles/Unit
complete list. For 100A Main
●
One or more of the
Breaker, contact the Flex
receptacles must be
Center (1-800-330-6479).
NEMA 6-20R2,
NEMA 5-20R2 or
Four Receptacles/Unit
NEMA 5-20R2GFI
All receptacles must be
●
NEMA 6-20R2,
NEMA 5-20R2 and/or
NEMA 5-20R2, or
NEMA 5-20R2GFI, surface
NEMA 5-20R2GFI must
mount only.
go in the second position
●

6
6
6
6
6

If two receptacles consist
of types NEMA 14-50R,
NEMA 10-50R,
NEMA 14-30R or
NEMA 6-20R2 a six-circuit
interior must be added
●
Example:
CHUIN5N2NSX

Note: Configuration 1 and 2 were
chosen so a six-circuit interior
needs to be added (suffix X) to
the end of the catalog number.
Also, configuration 5 is in the
second position.

6
6
6
6
6
6
6
V1-T6-10

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Two, One and Zero
Receptacles/Unit
Any configuration.
Options
●
●

●
●

Six-circuit interior
Factory-mounted
pedestal extension
Lighted
Bottom fed

6.2

Power Pedestals
Temporary Power/RV Park

Surface Type
Receptacle Description
Ampere
Series
Single Receptacle
CHU4S

Unmetered
(Compact Version)

Position
Left

Center

Right

1st

2nd

3rd

Catalog
Number

14-50R

—

No breaker

No breaker

No breaker

CHU1S

6
6

Unmetered Single Receptacle
50

Unmetered Type
CHU1N7N4NS

6

Breaker Description

—

6

30

—

14-30 R

—

No breaker

No breaker

No breaker

CHU3S

30

—

TT-30R

—

No breaker

No breaker

No breaker

CHU4S

20

—

6-20R2

—

No breaker

No breaker

No breaker

CHU5S

20

—

5-20R2

—

No breaker

No breaker

No breaker

CHU6S

20

—

5-20R2GFI

—

No breaker

No breaker

No breaker

CHU7S

20/20/20

5-20R2

5-20R2

6-20R2

GFI

GFI

GFI

CHU6G6G5GS

20/20/20

5-20R2GFI

5-20R2GFI

6-20R2

Non-GFI

Non-GFI

Non-GFI

CHU7N7N5NS

20/20/20

5-20R2GFI

5-20R2GFI

6-20R2

Non-GFI

Non-GFI

GFI

CHU7N7N5GS

50/20/30

14-50R

5-20R2GFI

TT-30R

Non-GFI

Non-GFI

Non-GFI

CHU1N7N4NS

50/20/30

14-50R

5-20R2GFI

6-20R

GFI

Non-GFI

Non-GFI

CHU1G7N7NS

50/20

14-50R

5-20RGFI

—

GFI

Non-GFI

—

CHU1G7NS

50/20

14-50R

5-20RGFI

—

Non-GFI

Non-GFI

—

CHU1N7NS

50/20/50

14-50R

5-20R2GFI

14-50R

Non-GFI

Non-GFI

Non-GFI

CHU1N7N1NSX 1

30/30/20

TT-30R

5-20R2GFI

TT-30R

Non-GFI

Non-GFI

Non-GFI

CHU4N7N4NS

20/20/20

5-20R2

5-20R2

6-20R2

GFI

GFI

GFI

CHU6G6G5GS6OM 2

6
6
6

Unmetered

6
6
6

Unmetered (Compact Version)
50

14-50R

—

—

Non-GFI

—

—

CHU1NS

20

5-20R2

—

—

Non-GFI

—

—

CHU2NS

30

TT-30R

—

—

GFI

—

—

CHU4GS

30/30

TT-30R

TT-30R

—

Non-GFI

Non-GFI

—

CHU4N4NS

30/20

TT-30R

5-20R2

—

Non-GFI

Non-GFI

—

CHU4N6NS

30/20

TT-30R

5-20R2GFI

—

Non-GFI

Non-GFI

—

CHU4N7NS

30

TT-30R

—

—

Non-GFI

—

—

CHU4NS

20

6-20R2

—

—

GFI

—

—

CHU5GS

20/20

5-20R2

5-20R2

—

GFI

GFI

—

CHU6G6GS

20

5-20R2

—

—

GFI

—

—

CHU6GS

20/20

5-20R2

5-20R2

—

Non-GFI

Non-GFI

—

CHU6N6NS

20

5-20R2

—

—

Non-GFI

—

—

CHU6NS

20/20

5-20R2GFI

5-20R2GFI

—

Non-GFI

Non-GFI

—

CHU7N7NS

20

5-20R2GFI

—

—

Non-GFI

—

—

CHU7NS

6
6
6
6
6
6
6
6
6
6
6
6

Notes
1 The “X” suffix indicates that a six circuit interior is provided, instead of the standard four circuit interior.
2 Includes 60A two-pole main breaker for service disconnect ratings.

6

Contact your local Eaton sales office for configurations not listed.

6
6
6
6
6
6
6

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-11

6.2

Temporary Power/RV Park

Surface Type, continued

6

Receptacle Description

6
6

Power Pedestals

Ampere
Series
Metered Ring
CHM1G7NS

6

Breaker Description

Position
Left

Center

Right

1st

2nd

3rd

Catalog
Number

Metered—Ring
50/20/20

14-50R

5-20R2GFI

5-20R2GFI

GFI

Non-GFI

Non-GFI

CHM1G7N7NS

20/20

5-20R2GFI

5-20R2GFI

—

Non-GFI

Non-GFI

—

CHM7N7NS

6

20/20/20

5-20R2GFI

5-20R2GFI

6-20R2

Non-GFI

Non-GFI

GFI

CHM7N7N5GS

20/20/20

5-20R2GFI

5-20R2GFI

6-20R2

Non-GFI

Non-GFI

Non-GFI

CHM7N7N5NS

6

50/30/20

14-50R

5-20R2GFI

TT-30R

Non-GFI

Non-GFI

Non-GFI

CHM1N7N4NS

50/20

14-50R

5-20R2GFI

—

Non-GFI

Non-GFI

—

CHM1N7NS

20/20

6-20R2

5-20R2GFI

—

Non-GFI

Non-GFI

Non-GFI

CHM5N7NS

5-20R2GFI

—

GFI

Non-GFI

—

CHR1G7NS

6
6
6
6

Metered Ringless Type
CHR4N7NS

Metered—Ringless

6

50/20

14-50R

20/20

5-20R2GFI

5-20R2GFI

—

Non-GFI

Non-GFI

—

CHR7N7NS

6

50/20/20

14-50R

5-20R2GFI

5-20R2GFI

GFI

Non-GFI

Non-GFI

CHR1G7N7NS

50/20

14-50R

5-20R2GFI

—

Non-GFI

Non-GFI

—

CHR1N7NS

6

20/20/20

5-20R2GFI

5-20R2GFI

5-20R2GFI

Non-GFI

Non-GFI

Non-GFI

CHR7N7N7NS

6

30/20/20

14-30R

5-20R2GFI

5-20R2GFI

Non-GFI

Non-GFI

Non-GFI

CHR3N7N7NS

50/30/20

14-50R

5-20R2GFI

TT-30R

Non-GFI

Non-GFI

Non-GFI

CHR1N7N4NS

6
6
6

Metered Ring or
Ringless Type
Bottom Feed

6

Metered—Ring—Bottom Fed
20/20

5-20R2GFI

5-20R2GFI

—

Non-GFI

Non-GFI

—

CHM7N7NSU

20/20/20

5-20R2GFI

5-20R2GFI

6-20R2

Non-GFI

Non-GFI

GFI

CHM7N7N5GSU

50/20/20

14-50R

5-20R2GFI

5-20R2GFI

GFI

Non-GFI

Non-GFI

CHM1G7N7NSU

6

Metered—Ringless—Bottom Fed
20/20

5-20R2GFI

5-20R2GFI

—

Non-GFI

Non-GFI

—

CHR7N7NSU

6

50/20

14-50R

5-20R2GFI

—

GFI

Non-GFI

—

CHR1G7NSU

50/20

10-50R

5-20R2GFI

—

GFI

Non-GFI

—

CHR2G7NSU

6

20/20/20

5-20R2GFI

5-20R2GFI

6-20R2

Non-GFI

Non-GFI

GFI

CHR7N7N5GSU

6

20/20/20

5-20R2GFI

5-20R2GFI

6-20R2

Non-GFI

Non-GFI

Non-GFI

CHR7N7N5NSU

20/20/20

5-20R2GFI

5-20R2GFI

5-20R2GFI

Non-GFI

Non-GFI

Non-GFI

CHR7N7N7NSU

6

30/20/20

14-30R

5-20R2GFI

5-20R2GFI

Non-GFI

Non-GFI

Non-GFI

CHR3N7N7NSU

30/20/20

14-30R

5-20R2GFI

5-20R2GFI

GFI

Non-GFI

Non-GFI

CHR3G7N7NSU

6

50/20/20

14-50R

5-20R2GFI

5-20R2GFI

GFI

Non-GFI

Non-GFI

CHR1G7N7NSU

50/20/30

14-50R

5-20R2GFI

TT-30R

Non-GFI

Non-GFI

Non-GFI

CHR1N7N4NSU

6
6

Accessories
See Page V1-T6-7.

6
6
6
6
V1-T6-12

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Power Pedestals
Temporary Power/RV Park

6.2

Dimensions

6

Approximate Dimensions in Inches (mm)

6

Single Receptacle

0.24
(6.1)

6

6.58
(167.1)

6

2.63
(66.8)

6
6
6
6
6

7.10
(108.3)

6

4.50
(114.3)

6
6

3.18
(80.8)

6

1.30
(33.0)

6
2.50
(63.5)

1.87
(47.5 )

6
6

6.23
(158.2)

6
6

4.79
(121.7)
4.27
(108.5)

6
6

0.13
(3.3)

6
6
6
6
6
6
6
6
6
6
Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-13

6.2

Power Pedestals
Temporary Power/RV Park

6

Approximate Dimensions in Inches (mm)

6

Compact Design Option

6

0.30
(7.62)

6.58
(167.1)

6

6.94
(176.3)

4.27
(108.5)

0.13
(3.3)

6
6
6
6

11.66
(296.2)

6

7.26
(184.4)

6

Center Line
for Receptacle

6

2.43
(61.7)

6

1.89
(48.0)

6

2.14
(54.4)

4.89
(124.2)

6
6
6
6
6

Unmetered Units

6

Unmetered Surface Type
4.30
(109.2)

9.50
(241.3)

6

0.07
(1.7)

6
6
6
6
6

17.10
(434.3)

14.50
(368.3)
Locking
Provision

6
6
6
6

6.70
(170.2)

6
V1-T6-14

1.30
(33.0)

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Power Pedestals
Temporary Power/RV Park

6.2

Approximate Dimensions in Inches (mm)

6

Metered Units (Ring and Ringless)

6

Metered Surface Type
4.50
(114.3)
4.30
(109.2)

9.50
(241.3)

6
6

0.07
(1.7)

6
6
6
6
6
6

30.00
(762.0)

6

22.50
(571.5)

6

Locking
Provision

6
6
6

6.70
(170.1)

Sealing
Provision

6
6

Bottom Fed Type
6.80
(172.8)
4.31
(109.5)

9.49
(241.1)

6
6

0.06
(1.6)

6
6
6
Locking
Provision

6
6

30.10
(764.6)

6
6

17.11
(434.7)

6

12.97
(329.4)

6

6.15
(156.2)

Sealing
Provision

6
6

4.93
(125.2)
Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-15

6.2
6

Power Pedestals
Temporary Power/RV Park

Contents

Power Outlet Panels

Description

6

Page

Product Overview. . . . . . . . . . . . . . . . . . . . . . . . . .
Surface Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pedestal Units . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6
6

V1-T6-3
V1-T6-10
V1-T6-16
V1-T6-18

6
6
6
6
6
6
6

Pedestal Units

6

Product Overview

6
6
6
6
6

A power outlet panel (or POP)
is a device designed for
outdoor service to meet
temporary power
requirements at construction
sites and recreation vehicle
(RV) parks. POPs provide a
safe and reliable means for
users to access electricity
at such locations.

6

Product Selection
Power Outlet Panel Receptacle Configuration Rules
See Page V1-T6-8 for
Three Receptacles/Unit
complete list. For 100A Main
●
One or more of the
Breaker, contact the Flex
receptacles must be
Center (1-800-330-6479).
NEMA 6-20R2,
NEMA 5-20R2 or
Four Receptacles/Unit
NEMA 5-20R2GFI
All receptacles must be
●
NEMA 6-20R2,
NEMA 5-20R2 and/or
NEMA 5-20R2, or
NEMA 5-20R2GFI, surface
NEMA 5-20R2GFI must
mount only.
go in the second position
●

6
6
6
6
6

If two receptacles consist
of types NEMA 14-50R,
NEMA 10-50R,
NEMA 14-30R or
NEMA 6-20R2 a six-circuit
interior must be added
●
Example:
CHUIN5N2NSX

Note: Configuration 1 and 2 were
chosen so a six-circuit interior
needs to be added (suffix X) to
the end of the catalog number.
Also, configuration 5 is in the
second position.

6
6
6
6
6
6
6
V1-T6-16

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Two, One and Zero
Receptacles/Unit
Any configuration.
Options
●
●

●
●

Six-circuit interior
Factory-mounted
pedestal extension
Lighted
Bottom fed

6.2

Power Pedestals
Temporary Power/RV Park

Unmetered Type

Pedestal Type
Receptacle Description
Ampere
Series

6

Breaker Description

Position

6

Left

Center

Right

1st

2nd

3rd

Catalog
Number

50/30/20

14-50R

5-20R2GFI

TT-30R

Non-GFI

Non-GFI

Non-GFI

CHU1N7N4NP

30/20

TT-30R

5-20R2GFI

—

Non-GFI

Non-GFI

—

CHU4N7NP

50/30/20

14-50R

5-20R2GFI

TT-30R

Non-GFI

Non-GFI

Non-GFI

CHU1N7N4NPTZ

6

Unmetered

6

TT-30R

5-20R2GFI

TT-30R

Non-GFI

Non-GFI

Non-GFI

CHU4N7N4NP

30/20

TT-30R

5-20R2GFI

—

Non-GFI

Non-GFI

—

CHU4N7NPTZ

50/30/20

14-50R

5-20R2GFI

TT-30R

Non-GFI

Non-GFI

Non-GFI

CHM1N7N4NP

50/20

14-50R

5-20R2GFI

—

Non-GFI

Non-GFI

—

CHM1N7NP

50/30/20

14-50R

5-20R2GFI

TT-30R

Non-GFI

Non-GFI

Non-GFI

CHM1N7N4NPTZ

30/20

TT-30R

5-20R2GFI

—

Non-GFI

Non-GFI

—

CHM4N7NPTZ

6
6

6

Metered—Ring
CHM1N7N4NPTZ

6

30/30/20

Metered—Ringless
50/30/20

14-50R

5-20R2GFI

TT-30R

Non-GFI

Non-GFI

Non-GFI

CHR1N7N4NP

50/20/50

14-50R

5-20R2GFI

14-50R

Non-GFI

Non-GFI

Non-GFI

CHR1N7N1NPX

50/20/30

14-50R

5-20R2GFI

14-30R

Non-GFI

Non-GFI

Non-GFI

CHR1N7N3NPX

50/20/30

14-50R

5-20R2

14-30R

Non-GFI

Ground fault

Non-GFI

CHR1N6G3NPX

6
6

6
6
6
6
6
6

CHU1N7N4NBTZ

6

Back-to-Back Pedestal Type
Receptacle Description
Ampere
Series

Breaker Description

Position
Left

Center

Right

1st

2nd

3rd

Catalog
Number

6
6

Unmetered 1
30/30/20

TT-30R

5-20R2GFI

TT-30R

Non-GFI

Non-GFI

Non-GFI

CHU4N7N4NB

50/30/20

14-50R

5-20R2GFI

TT-30R

Non-GFI

Non-GFI

Non-GFI

CHU1N7N4NBTZ

Metered—Ring

1

30/20

TT-30R

5-20R2GFI

—

Non-GFI

Non-GFI

—

CHM4N7NB

50/30/20

14-50R

5-20R2GFI

TT-30R

Non-GFI

Non-GFI

Non-GFI

CHM1N7N4NB

5-20R2GFI

TT-30R

Non-GFI

Non-GFI

Non-GFI

CHR1N7N4NBTZ

6

Metered—Ringless 1
50/30/20

14-50R

6
6
6
6
6

Notes
1 The pedestal back-to-back units have receptacles and circuit breakers as shown for each panel and share one common pedestal with loop feed lugs.

6

Contact your local Eaton sales office for configurations not listed.

6

Accessories
See Page V1-T6-7.

6
6
6
Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-17

6.2
6

Power Pedestals
Temporary Power/RV Park

Dimensions
Approximate Dimensions in Inches (mm)

6

Metered Units

6

100A Pedestal
Ringless
U.G. Feed Pedestal-Mount

6
6
6
6

.79
(20.1)

6

.904

6

6

100A

1"

Secondary
Hit Exit
Hole B/B
Only

A

N

B

6.10
(154.9)

Sections Through at
Meter Socket .63
(15.9)

6
6

1"

100A

4.108

6

6

100A

4.00
(101.6)

3.077

6

6

Gasket
.92 (23.4)

ÿ2.500

6
6

1"

100A

4.00
(101.6)

100A

4.46
(113.3)

100A

6

.12
(3.1)

1"

A0 01

10.78
(273.7)

1"

10.24
(260.0)

A0 01

6

1"

7.44
(188.9)

18.02
(457.7)
Sections Through
At Upper Barrier

ÿ2.50
(63.5)
ÿ1.50

Sections Through
At Lower Barrier

6
6
6

33.00
(838.2)

33.00
(838.2)

6
6
6
6
6
6

STRIP

CURRENT INTERRUPTING RATING
MAX. RMS SYM. AMPERES

10,000
AT 120/240 VOLTS AC

.438

6
V1-T6-18

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Power Pedestals
Temporary Power/RV Park

6.2

Approximate Dimensions in Inches (mm)

6

Metered Units (Ring and Ringless)

6

Metered Back-to-Back Pedestal Type

6
6
6
6
6
6
6
6
6
6
6
6
6

0.75
(19.1)

6

Bottom Fed Type
6.80
(172.8)
4.31
(109.5)

9.49
(241.1)

6
6
0.06
(1.6)

6
6
6
6

Locking
Provision

6
6

30.10
(764.6)

6
6

17.11
(434.7)

6

12.97
(329.4)

6

6.15
(156.2)

6
Sealing
Provision

4.93
(125.2)

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

6
V1-T6-19

6.2
6
6

Power Pedestals
Temporary Power/RV Park

Approximate Dimensions in Inches (mm)
Unmetered Back-to-Back Pedestal Type
13.60
(345.4)
8.60 (218.4)

6
6
6

Locking
Provision

6
6
6
6
6

19.20
(487.7)

6
6
6
6
6

0.75
(19.1)

Unmetered Pedestal Type

6

3.30
(83.8)

Metered Pedestal Type

9.50
(241.3)

6.80
5.00 (172.7)
(127.0)

9.50
(241.3)

6
6
6
6
6

39.10
(993.1)

6

39.90
(1013.5)

52.00
(1320.8)

Locking
Provision

6
44.50
(1130.3)

6
6
6

25.80
(655.3)

22.00
(558.8)
16.90
(429.3)

6

9.20
(233.7)
9.40
(238.8)

6
6

Sealing
Provision

6
V1-T6-20

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

4.30
(109.2)

Power Pedestals
Mobile Home Panels

6.3

Contents

Power Outlet Panels

Description

Page

Mobile Home Panels
Catalog Number Selection . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .

V1-T6-22
V1-T6-22
V1-T6-23
V1-T6-24

6
6
6
6
6
6
6
6
6
6

Product Overview
Eaton’s versatile Mobile
Home Panels have a userfriendly design that allows for
a faster, cleaner installation.
100 and 200A panels come
complete with the main
breaker and a 4/8 or 8/16
interior, respectively. The
200A units are designed with
ample width to ensure plenty
of room for wire bending and
an easier installation.

6

Features
Receptacle Deadfront Kits

Fastenerless Socket Design

Optional receptacle
deadfront kits enable the
field installation of contractor
supplied receptacles and
breakers that can supply
power for a variety of
applications including:

●

●
●
●
●
●

Visiting RVs
Temporary power
Lawn equipment
Air compressors
Anything else that requires
cord-connected power

Eliminates overheating
caused by loose socket
connections

Pedestal Unit
●

●

Convenient and sturdy
ground mounting
Loop feed feature allows
several units to be
connected in series

6

Easier, Better and
Faster Installation
●

●

More wire bending and
viewing room
Additional circuits mean
more flexibility

6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-21

6.3
6
6

Power Pedestals
Mobile Home Panels

Catalog Number Selection
Mobile Home Panels

MH M 100 P 1 N 4 N

6
6

Type
MH = Mobile Home Panel

6

Circuit Breaker Type
Position 2

Metering Type
M = Metered-ring
R = Metered-ringless

6
6

Amperes
100
150
200

6
6
6
6
6
6
6

Circuit Breaker Type
Position 1

Mounting
P = Pedestal
B = Back-to-back

N = Non-ground fault
G = Ground fault

Optional Receptacle Type
Position 1
1=
NEMA 14-50R
3=
NEMA 14-30R
4=
NEMA TT-30R
5=
NEMA 6-20R2
6=
NEMA 5-20R2
7=
NEMA 5-20R2GFI
8=
NEMA 5-20R2GFI (WR)
9=
NEMA 5-20R2GFI (WR/TR)
Blank = No receptacle

N = Non-ground fault
G = Ground fault
Optional Receptacle Type
Position 2
1=
NEMA 14-50R
3=
NEMA 14-30R
4=
NEMA TT-30R
5=
NEMA 6-20R2
6=
NEMA 5-20R2
7=
NEMA 5-20R2GFI
8=
NEMA 5-20R2GFI (WR)
9=
NEMA 5-20R2GFI (WR/TR)
Blank = No receptacle

Product Selection
Mobile Home Panel

Mobile Home Panels 1
Amperes

Security

Interior

Main

Branch
Breakers

Receptacles

Catalog
Number

100

Ring

4/8

BR2100

BR

100

Ring

4/8

BR2100

BR

Pedestal

None

MHM100P

Back-to-back

None

6

100

Ringless

4/8

BR2100

BR

MHM100B

Pedestal

None

100

Ringless

4/8

BR2100

MHR100P

BR

Back-to-back

None

6

150

Ring

8/16

MHR100B

CSR2150

BR

Pedestal

None

150

Ring

MHM150P

8/16

CSR2150

BR

Back-to-back

None

6

150

MHM150B

Ringless

8/16

CSR2150

BR

Pedestal

None

MHR150P

150

Ringless

8/16

CSR2150

BR

Back-to-back

None

MHR150B

6

200

Ring

8/16

CSR2200

BR

Pedestal

None

MHM200P

6

200

Ring

8/16

CSR2200

BR

Back-to-back

None

MHM200B

200

Ringless

8/16

CSR2200

BR

Pedestal

None

MHR200P

6

200

Ringless

8/16

CSR2200

BR

Back-to-back

None

MHR200B

200

Ringless

8/16

CSR2200

BR

Pedestal

Qty 1 14-50R
Qty 2 TT-30R

MHM200P1N4N4N

6
6

6

Mounting

Note
1 Pedestal Extension included with Mobile Home Panels.

6
6
6
6
6
6
6
V1-T6-22

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Power Pedestals
Mobile Home Panels

6.3

Mobile Home Panel Deadfronts for 200A Units 1

6

Available Receptacle Deadfront Kits—Receptacles and
Breakers Not Included

6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Accessories

6

Mobile Home Panels
Hubs not used on mobile home panels.
Description

Amperes

Catalog
Number

Direct feed kit

—

MHDFK

Pedestal extension

200

MHPEDEXT

Stainless steel pedestal extension

200

MHPEDEXTSS

Padmount adapter

200

MHPADEXT

Pedestal extension

100

CHPEDEXT100

Stainless steel pedestal extension

100

CHPEDESTSS100

Padmount adapter

100

CHPADEXT100

6
6
6
6
6
6

Note
1 For 100A units, the accessory Catalog Number would be MHD1___. For example, to order
a deadfront to accept one 30A receptacle (round) in a 100 ampere device, the Catalog
Number would be MHD1X.

6
6
6
6

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-23

6.3
6
6
6

Power Pedestals
Mobile Home Panels

Dimensions
Approximate Dimensions in Inches (mm)
Mobile Home Panel—Ringless—Pedestal Mounting
Ringless
Socket
Rated 200 A
Continuous

6

5.98
(152.0)

6

14.45
(367.0)

5.31
(134.8)

6
6
6
6

1-1/4, 1-1/2,
2, 2-1/2
(31.8, 38.1,
50.8, 63.5)
Knockout

1, 1-1/4, 1-1/2, 2
(25.4, 31.8, 38.1, 50.8)
Knockout

ON

5/16 (7.9)
Diameter KO
Opposite
Side Only

6

OFF

Sealing
Provision

Door Not
Shown

57.81
(1468.3)

6

200A
Main
Breaker

50.08
(1272.1)

6

Optional Direct
Feed Kit
Shown Installed
(Cover Not Shown)

6

28.01
(711.5)

6
6

27.87
(708.0)
24.65
(626.1)

28.70
(729.0)
1/2, 3/4,1
(12.7, 19.1, 25.4)
KO (2 Required)

23.69
(601.8)

2.00
(50.8)

6

43.20
(1097.4)

1/2, 3/4, 1, 1-1/4,
1-1/2 (12.7, 19.1,
25.4, 31.8, 38.1) KO

Sealing Provision
1.21
(30.7)

Bottom Endwall
Direct Feed Kit

Grade Level

6
6
6
6
6
6
6
6
6
6
6
6
6
6
V1-T6-24

1, 1-1/4, 1-1/2, 2
(25.4, 31.8, 38.1,
50.8) KO

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

6.3

Power Pedestals
Mobile Home Panels

6

Approximate Dimensions in Inches (mm)

6

Mobile Home Panel—Ringless—Back-to-Back Mounting

6

Front View

Back View

12.09
(307.2)

6

Ringless
Socket
Rated 200 A
Continuous
10.75
(272.9)

6

14.45
(367.0)

6

Sealing
Provision
57.81
(1468.3) Door
Not
Shown
5/16 (7.9)
Diameter
KO
Opposite
200A
Side Only
Main
Breaker

1-1/4, 1-1/2,
2, 2-1/2
(31.8, 38.1,
50.8, 63.5)
Knockout

1,1-1/4,
1-1/2, 2
(25.4, 31.8,
38.1, 50.8)
Knockout

6

3/4, 1 (19.1, 25.4) KO
5/16 (7.9) Diameter
KO (3) Required

6
1/2, 3/4 (12.7, 19.1)
KO (2) Required

6

1-1/2, 2, 2-1/2, 3
(38.1, 50.8, 63.5, 76.2) KO

Bottom Endwall Back Unit

50.08
(1272.1)

22.01
(711.5)

6

1/2 (12.7) KO
(3) Required

ON

5/16 (7.9)
Diameter
KO Opposite
Side Only

OFF

ON

Door Not
Shown

OFF

1-1/4, 1-1/2, 2, 2-1/2
(31.8, 38.1, 50.8, 63.5) KO
(2) Required

Optional Direct
Feed Kit Shown
Installed
(Cover Not
Shown)

1/2, 3/4, 1 (12.7,
19.1, 25.4) KO
(2) Required

28.70
(729.0)

18.69
(474.6)
2.00
(50.8)

23.69
(601.8)

1.21
(30.7)

6

43.20
(1097.4)

27.87
(708.0)
25.00
(635.0)

6

Sealing
Provision

6
1, 1-1/4, 1-1/2, 2
(25.4, 31.8, 38.1, 50.8) KO

6

1/2, 3/4, 1, 1-1/4, 1-1/2
(12.7, 19.1, 25.4, 31.8,
38.1) KO

6
6

Bottom Endwall Direct Feed Kit

6

Grade Level

6
6
6
6
6
6
6
6
6
6
6
6
6
Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-25

6.3

Power Pedestals
Mobile Home Panels

6

Approximate Dimensions in Inches (mm)

6

Mobile Home Panel—Ring—Pedestal Mounting
5.56
(141.3)

6

5.31
(134.8)

14.45
(367.0)

Ring Type Socket
Rated 200 A Continuous

6
5/16 (7.9)
Diameter
KO
Opposite
Side Only

6
6
6

1-1/4,
1-1/2, 2,
2-1/2
(31.8, 38.1,
50.8, 63.5)
Knockout

1, 1-1/4,
1-1/2, 2
(25.4,
31.8, 38.1,
50.8) KO

Door
Not
Shown
200A
Main
Breaker

57.81
(1468.3)

6

50.08
(1272.1)

6
6

ON

6

OFF

6

43.20
(1097.4)

Optional Direct Feed Kit
Shown Installed
(Cover Not Shown)

24.64
(626.0)

6

2.00
(50.8)

6

27.87
(708.0)

Bottom Endwall
Direct Feed Kit

23.69
(601.8)
Sealing
Provision

1.21
(30.7)

Grade Level

6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
V1-T6-26

1, 1-1/4, 1-1/2,
2 (25.4, 31.8,
38.1, 50.8) KO
1/2, 3/4, 1, 1-1/4,
1-1/2 (12.7, 19.1,
25.4, 31.8, 38.1) KO

28.70
(729.0)

28.01
(711.5)

6

1/2, 3/4, 1 (12.7,
19.1, 25.4) KO
(2 Required)

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

6.3

Power Pedestals
Mobile Home Panels

Approximate Dimensions in Inches (mm)

6
6

Mobile Home Panel—Ring—Back-to-Back Mounting
Front View

Back View
11.25
(285.8)

10.75
(273.0)

14.45
(367.0)

6

Ring Type Socket
Rated 200 A Continuous

6
6

1-1/4,
1-1/2, 2,
2-1/2
(31.8,
38.1, 50.8,
63.5)
Knockout

57.81
(1468.3)

ON

6
6

OFF

ON

OFF

Door Not
Shown

200A
Main
Breaker

5/16 (7.9)
Diameter KO

Door
Not
Shown

1-1/4, 1-1/2, 2, 2-1/2
(31.8, 38.1, 50.8, 63.5)
KO (2) Required
1/2 (12.7) KO
(3) Required

1, 1-1/4, 1-1/2, 2
(25.4, 31.8,
38.1, 50.8)
Knockout

6

5/16 (7.9) Diameter
KO (3) Required

6

50.08
(1272.1)
43.20
(1097.4)

22.01
(711.5)

6
3/4, 1 (19.1, 25.4) KO

Optional Direct
Feed Kit
Shown Installed
(Cover Not
Shown)

27.87
(708.0)

23.69
(601.8)

18.69
(474.6)

6

Bottom Endwall
Back Unit

28.70
(729.0)

25.00
(635.0)

6

1/2, 3/4 (12.7, 19.1) 1-1/2, 2, 2-1/2, 3 (38.1,
50.8, 63.5, 76.2) KO
KO (2) Required

Grade Level
Sealing Provision

1/2, 3/4, 1 (12.7,
19.1, 25.4) KO
(2) Required

6
1, 1-1/4, 1-1/2, 2 (25.4,
31.8, 38.1, 50.8) KO

6

1/2, 3/4, 1, 1-1/4,
1-1/2 (12.7, 19.1,
25.4, 31.8, 38.1) KO

6
6

Bottom Endwall
Direct Feed Kit

6
6
6
6
6
6
6
6
6
6
6
6
6
6

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-27

6.4
6

Power Pedestals
RV Park Hook-Ups

Contents

Recreational Vehicle/Campground Products

Description

6

Power Pedestals
Product Selection Guide . . . . . . . . . . . . . . . . .
Powerhouse Power Pedestal . . . . . . . . . . . . . . . .
Powerhouse—Stainless Steel (SS) Power Pedestal
Newport Camp Mate Power Pedestal . . . . . . . . .
Park Light Power Pedestal . . . . . . . . . . . . . . . . . .
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters . . . . . . . . .
Distribution Equipment—Ground Fault Monitor . .
Distribution Equipment—Substations. . . . . . . . . .
Distribution Equipment—Panels . . . . . . . . . . . . . .
Distribution Equipment—Transformers. . . . . . . . .

6
6
6
6
6
6
6

High-Quality, Weatherproof Electrical Equipment

6
6

Power Pedestals

6

Product Overview

6
6
6
6
6
6
6
6
6
6

On March 24, 2006, RV Park
Hook-Ups® joined together
with Eaton to provide
unmatched products and
services in the recreational
vehicle industry, as well as
the marina industry. Known
as the leader in electrical
control, power distribution,
and industrial automation
products and services, Eaton
is a quality driven company
that constantly looks for ways
to provide enhanced products
and service solutions for their
customers. Eaton will be able
to provide RV park developers
a complete electrical solution.
For more information on the
other products available from
Eaton, visit us online at
www.eaton.com or
www.rvparkhookups.com

What Eaton has to Offer
●
Complementary
comprehensive in-house
electrical designs for your
complete RV or marina
development
●
RV and marina power
pedestals
●
Custom substations
●
Transformers
●
Panels
●
Wire
●
Digital electronic meters
●
Receptacles and breakers
●
Specialized electrical parts
and equipment

6
6
6
6
6
6
6
6
V1-T6-28

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-29
V1-T6-30
V1-T6-33
V1-T6-36
V1-T6-39
V1-T6-42
V1-T6-44
V1-T6-45
V1-T6-46
V1-T6-49
V1-T6-50

6.4

Power Pedestals
RV Park Hook-Ups

Product Selection Guide

6

Power Receptacles

6
6
6
6
6
6
6
6

Power Outlets
Side One

6

Maximum GFI
Side Two

Phase

Powerhouse

Powerhouse–SS

Newport Camp Mate

Park Light

None

None

1

2

2

2

2

30–20

00

1

2

2

1

1

30–20

30–20

1

2

2

—

—

30–30–20

30–30–20

1

2

2

—

—

30–20

50–20

1

2

2

—

—

30–30–20

50–20

1

2

2

—

—

30–30–20

30–50–20

1

2

2

—

—

30–30–20

50–50–20

1

2

2

—

—

30–50–20

30–50–20

1

2

2

—

—

30–50–20

50–50–20

1

2

2

—

—

50–20

None

1

2

2

—

—

50–20

50–20

1

2

2

—

—

50–50–20

50–20

1

2

2

—

—

50–50–20

50–50–20

1

2

2

—

—

30–50–20

None

1

2

2

0

—

6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-29

6.4
6

Power Pedestals
RV Park Hook-Ups

Contents

Powerhouse Power Pedestal

Description

6
6
6
6
6
6
6
6
6
6

Powerhouse Power Pedestal

6

Product Description

Features

The Powerhouse® RV utility
center is our most popular
pedestal for single or double
RV sites because of its full
complement of standard
features and available option
packages able to meet any
user requirement. The
housing is made of durable
weatherproof engineered
resin and will never rust or
deteriorate.

●

6
6
6
6
6
6
6
6
6
6

Page

Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . .
Powerhouse Power Pedestal
Standards and Certifications . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .
Powerhouse—Stainless Steel (SS) Power Pedestal
Newport Camp Mate Power Pedestal . . . . . . . . .
Park Light Power Pedestal . . . . . . . . . . . . . . . . . .
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters . . . . . . . . .
Distribution Equipment—Ground Fault Monitor . .
Distribution Equipment—Substations. . . . . . . . . .
Distribution Equipment—Panels . . . . . . . . . . . . . .
Distribution Equipment—Transformers. . . . . . . . .

That’s why it comes with a
limited lifetime warranty.
Since the Powerhouse can
accommodate two RV sites,
it’s an economical pedestal
for double site installation.
This unit is ideal for new, or
when retrofitting, full-service
RV parks.

●

●
●

●

●

●

Photocell controlled
13 watt fluorescent light
with amber lens
Lockable weatherproof
doors that protect
receptacles and breakers
Hose and cable brackets
Engineered resin
housing with a two-part
polyurethane coating for a
UV-resistant, long-lasting
finish
Limited lifetime warranty
on the housing
Loop-feed mechanical
busbars that can accept up
to 250 kcmil wire
Hinged pedestal base
providing easy access
for installation and
maintenance

V1-T6-31
V1-T6-31
V1-T6-32
V1-T6-32
V1-T6-33
V1-T6-36
V1-T6-39
V1-T6-42
V1-T6-44
V1-T6-45
V1-T6-46
V1-T6-49
V1-T6-50

Available Options
Surge Protection
SurgeTrap is designed
to protect electrical and
electronic loads from
transients and surge
disturbances on your AC
power line, such as voltage
surges, spikes and lighting.
The SurgeTrap has a lifetime
warranty where Eaton will
replace the SurgeTrap device
at no charge.
●

●
●
●

●

175 kA maximum
surge current
3500 joules
Type 3R enclosure
Comes with a protection
working indicator light
Factory installed integral
to pedestal or available
for retrofit

6

●
●

●

●
●

●

●

●
●

●

6

●

6

●

6

●

6
6

●

6

●

6
V1-T6-30

V1-T6-28

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Clear lens
Photocell controlled single
or dual 7 watt or 13 watt
fluorescent light
Telephone (RJ-11) for
each side
Cable TV for each side
High-speed Internet
connector (RJ-45) for
each side
Water—single or dual
1/4-turn brass ball valves
(brass “T” connection)
with 3/4-inch hose bibs
Water meters with remote
capability
Water—anti-siphon faucet
Loop-feed 3/8-inch stud
lug copper busbar for
up to 250 kcmil wire
(recommended for salt
water environments)
Single-feed mechanical
busbars for up to
250 kcmil wire
Digital electronic meter
for each side
Wireless remote reading of
electronic kilowatt meters
Meter socket for each side
powered (to accept glass
style meter)
Direct burial ground
mounting stand stainless
or galvanized
Custom paint color

Power Pedestals
RV Park Hook-Ups

6.4

Standards and Certifications
●

6

UL/CSA listed

6
6
6

Catalog Number Selection

6

P D U 4 7 0 0 0 0 0 0 1 2 K M

6

Type
P = Powerhouse
Z = PHSS
Lighting and Lens Color
A = 7W light
Amber
B = Dual 7W light Amber
C = 9W light
Amber
D = 13W light
Amber
E = Dual 13W light Amber
F = No lighting
Amber
G = 7W light
Clear
H = Dual 7W light Clear
I = 9W light
Clear
J = 13W light
Clear
K = Dual 13W light Clear
L = No lighting
Clear
M = 7W light
Special
N = Dual 7W light Special
O = 9W light
Special
P = 13W light
Special
Q = Dual 13W light Special
R = No lighting
Special
S = 350 MA LED
Amber
T = 700 MA LED
Amber
U = 350 MA LED
Clear
V = 700 MA LED
Clear
W = 350 MA LED
Special
Y = 700 MA LED
Special
Metering Type
U = Unmetered
D = Digital electronic meters
(side one)
T = Digital electronic meters
(side two)
B = Digital electronic meters
(both sides)
R = Receptacles metered
individually
M = One meter socket
(100A)
N = Two meter socket
(100A each)

R2S2

R3S2

R4S2

R4S1

R3S1

0
0
0
1
1
1
2
2
2
3
3
3
4
4
4
5
5
5
6
6
6
7
7
7
8
8
8
= None
= 20A GFI duplex
= 30A, 125V
= 50A, 125/250V
= 100A, 208V
= 100A, 250V
= 100A, 277/480V
= 100A, 480V

R1S2

0
1
2
3
4
5
6
7
8
0
1
2
4
5
6
7
8

R2S1

R1S1

Sides and Receptacles

0
1
2
3
4
5
6
7
8

0
1
2
3
4
5
6
7
8

0
1
2
3
4
5
6
7
8

0
1
2
3
4
5
6
7
8

0
1
2
3
4
5
6
7

Water Option 1
=0
=1
=2
= Single water meter
= Dual water meter
= Single meter, 2V
= 1 frost free
= 2 frost free
Extra Unmetered GFI
Receptacles
0 = None
1 =1
2 =2

6

Phone Cable TV and Internet Options
Phone
Cable TV
Internet
Jack
Jack
Option
A= 1
0
0
B= 1
0
1
C= 1
0
2
D= 1
1
0
E= 1
1
1
F= 1
1
2
G= 1
2
0
H= 1
2
1
I= 1
2
2
J= 2
0
0
K= 2
0
1
L= 2
0
2
M= 2
1
0
N= 2
1
1
O= 2
1
2
P= 2
2
0
Q= 2
2
1
R= 2
2
2
S= 0
2
2
T= 0
0
1
U= 0
0
2
V= 0
1
0
W= 0
1
1
X= 0
1
2
Y= 0
2
0
Z= 0
2
1
0= 0
0
0

6
6
6
6
6
6
6
6
6
6
6

Bus
S = Single-phase 3/8-inch copper busbar
F = Three-phase 3/8-inch copper busbar
C = Single-phase 3/8-inch Canadian busbar
T = Three-phase 3/8-inch Canadian busbar
M = Single-phase 300 kcmil mechanical lug bus
Z = Three-phase 300 kcmil mechanical lug bus
L = Single-phase 350 kcmil mechanical lug bus
P = Three-phase 350 kcmil mechanical lug bus
N = Single-phase 1/4-inch copper busbar
Q = Single-phase 1/4-inch split mechanical busbar
A = Single-phase 300 kcmil mechanical lug Canadian bus
B = Three-phase 300 kcmil mechanical lug Canadian bus
D = Single-phase 350 kcmil mechanical lug Canadian bus
E = Three-phase 350 kcmil mechanical lug Canadian bus

6
6
6
6
6
6

Receptacle: R1S1 = Receptacle 1, Side 1
R2S1 = Receptacle 2, Side 1
R3S1 = Receptacle 3, Side 1
R1S2 = Receptacle 1, Side 2
R2S2 = Receptacle 2, Side 2
R3S2 = Receptacle 3, Side 2

6

Notes
1 Number represents the quantity of 1/4-turn ball valves with 3/4-inch hose bibs.

6

Internet option also available. Contact factory for details.

6

6
6

6
Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-31

6.4
6
6

Power Pedestals
RV Park Hook-Ups

Accessories
See Page V1-T6-75.

Dimensions

6

Approximate Dimensions in Inches (mm)

6

Powerhouse

6
6
6
6
6
6

Top

6
6

44.00
(1117.6)

6
6
6
6
6
6

Side View

Front View

6
6
6
6
6
6
6
13.75
(349.2)

6

Broken View

6
6
6
6
V1-T6-32

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Power Pedestals
RV Park Hook-Ups

Powerhouse—Stainless Steel (SS) Power Pedestal

6.4

Contents
Description

Page

Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . .
Powerhouse Power Pedestal. . . . . . . . . . . . . . . . .
Powerhouse—Stainless Steel (SS) Power Pedestal
Catalog Number Selection . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .
Newport Camp Mate Power Pedestal . . . . . . . . . .
Park Light Power Pedestal. . . . . . . . . . . . . . . . . . .
Firehouse. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters . . . . . . . . .
Distribution Equipment—Ground Fault Monitor . .
Distribution Equipment—Substations . . . . . . . . . .
Distribution Equipment—Panels . . . . . . . . . . . . . .
Distribution Equipment—Transformers . . . . . . . . .

V1-T6-28
V1-T6-30
V1-T6-34
V1-T6-35
V1-T6-35
V1-T6-36
V1-T6-39
V1-T6-42
V1-T6-44
V1-T6-45
V1-T6-46
V1-T6-49
V1-T6-50

6
6
6
6
6
6
6
6
6
6
6

Powerhouse—Stainless Steel (SS) Power Pedestal
Product Description

Features

For long-lasting durability
and low maintenance,
the new stainless steel
Powerhouse–SS pedestal
is the most resilient power
center offered.

●

We have designed a stainless
steel pedestal that will meet
and exceed all applicable
codes and withstand harsh
inland and coastal
environments.

●

●

●

●

●
●
●

Stainless steel housing
with a limited lifetime
warranty
Photocell controlled
13 watt fluorescent light
with amber lens
Large removable access
panel for easy installation
and maintenance
Weatherproof doors
that protect receptacles
and breakers
Backlit faceplate to aid in
hooking up at night
Hose and cable brackets
Powder-coated finish
Loop-feed mechanical
busbars that can accept up
to 350 kcmil wire

Available Options
●
●

●

●
●

●

●

●
●

●

Clear lens
Photocell controlled single
or dual 7 watt or 13 watt
fluorescent light
Telephone (RJ-11) for
each side
Cable TV for each side
High-speed Internet
connection (RJ-45) for each
side
Water–single or dual
1/4-turn brass ball valves
(brass “T” connection)
with 3/4-inch hose bibs
Water meters with
remote capability
Water—anti-siphon faucet
Direct burial stainless steel
ground mounting stand
Lockable doors

●

●

●

●

●

●

Loop-feed 3/8-inch stud
lug copper busbar for
up to 350 kcmil wire
(recommended for salt
water environments)
Single-feed mechanical
busbars for up to
350 kcmil wire
Digital electronic metering
for each side
Wireless remote reading of
electronic kilowatt meters
Meter socket for each side
powered (to accept glass
style meter)
Four door design to add
more outlets per pedestal

6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-33

6.4

RV Park Hook-Ups

Catalog Number Selection

Z D U 4 7 0 0 0 0 0 0 1 2 K M

6

6
6
6
6
6

Metering Type
U = Unmetered
D = Digital electronic meters
(side one)
T = Digital electronic meters
(side two)
B = Digital electronic meters
(both sides)
R = Receptacles metered
individually
M = One meter socket
(100A)
N = Two meter socket
(100A each)

6
6
6
6
6
6
6
6
6
6
6

0
1
2
3
4
5
6
7
8
0
1
2
4
5
6
7
8

0
0
0
1
1
1
2
2
2
3
3
3
4
4
4
5
5
5
6
6
6
7
7
7
8
8
8
= None
= 20A GFI duplex
= 30A, 125V
= 50A, 125/250V
= 100A, 208V
= 100A, 250V
= 100A, 277/480V
= 100A, 480V

R4S2

6

R3S2

6

Sides and Receptacles
R2S2

6

R1S2

6

Lighting and Lens Color
A = 7W light
Amber
B = Dual 7W light Amber
C = 9W light
Amber
D = 13W light
Amber
E = Dual 13W light Amber
F = No lighting
Amber
G = 7W light
Clear
H = Dual 7W light Clear
I = 9W light
Clear
J = 13W light
Clear
K = Dual 13W light Clear
L = No lighting
Clear
M = 7W light
Special
N = Dual 7W light Special
O = 9W light
Special
P = 13W light
Special
Q = Dual 13W light Special
R = No lighting
Special
S = 350 MA LED
Amber
T = 700 MA LED
Amber
U = 350 MA LED
Clear
V = 700 MA LED
Clear
W = 350 MA LED
Special
Y = 700 MA LED
Special

R4S1

6

R2S1

6

Type
P = Powerhouse
Z = PHSS

R1S1

6

R3S1

6

Power Pedestals

0
1
2
3
4
5
6
7
8

0
1
2
3
4
5
6
7
8

0
1
2
3
4
5
6
7
8

0
1
2
3
4
5
6
7
8

0
1
2
3
4
5
6
7

Water Option 1
=0
=1
=2
= Single water meter
= Dual water meter
= Single meter, 2V
= 1 frost free
= 2 frost free
Extra Unmetered GFI
Receptacles
0 = None
1 =1
2 =2

Phone Cable TV and Internet Options
Phone
Cable TV
Internet
Jack
Jack
Option
A = 1
0
0
B = 1
0
1
C = 1
0
2
D = 1
1
0
E = 1
1
1
F = 1
1
2
G = 1
2
0
H = 1
2
1
I = 1
2
2
J = 2
0
0
K = 2
0
1
L = 2
0
2
M= 2
1
0
N= 2
1
1
O = 2
1
2
P = 2
2
0
Q = 2
2
1
R = 2
2
2
S = 0
2
2
T = 0
0
1
U = 0
0
2
V = 0
1
0
W= 0
1
1
X = 0
1
2
Y = 0
2
0
Z = 0
2
1
0 = 0
0
0

Bus
S = Single-phase 3/8-inch copper busbar
F = Three-phase 3/8-inch copper busbar
C = Single-phase 3/8-inch Canadian busbar
T = Three-phase 3/8-inch Canadian busbar
M = Single-phase 300 kcmil mechanical lug bus
Z = Three-phase 300 kcmil mechanical lug bus
L = Single-phase 350 kcmil mechanical lug bus
P = Three-phase 350 kcmil mechanical lug bus
N = Single-phase 1/4-inch copper busbar
Q = Single-phase 1/4-inch split mechanical busbar
A = Single-phase 300 kcmil mechanical lug Canadian bus
B = Three-phase 300 kcmil mechanical lug Canadian bus
D = Single-phase 350 kcmil mechanical lug Canadian bus
E = Three-phase 350 kcmil mechanical lug Canadian bus

Receptacle: R1S1 = Receptacle 1, Side 1
R2S1 = Receptacle 2, Side 1
R3S1 = Receptacle 3, Side 1
R1S2 = Receptacle 1, Side 2
R2S2 = Receptacle 2, Side 2
R3S2 = Receptacle 3, Side 2
Notes
1 Number represents the quantity of 1/4-turn ball valves with 3/4-inch hose bibs.
Internet option also available. Contact factory for details.

6
6
6
6
6
V1-T6-34

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Power Pedestals
RV Park Hook-Ups

6.4

Accessories

6

See Page V1-T6-75.

6

Dimensions
Approximate Dimensions in Inches (mm)

6

Powerhouse—Stainless Steel (SS)

6
6
6
6
6
6
6
6
6
6
40.00
(1016.0)

6
6
6
6
6
6
6
6
6
6
6

9.88
(251.0)

6
6
6
6
6
6
Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-35

6.4
6

Power Pedestals
RV Park Hook-Ups

Contents

Newport Camp Mate Power Pedestal

Description

6

Page

Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . .
Powerhouse Power Pedestal . . . . . . . . . . . . . . . .
Powerhouse—Stainless Steel (SS) Power Pedestal
Newport Camp Mate Power Pedestal
Catalog Number Selection . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .
Park Light Power Pedestal . . . . . . . . . . . . . . . . . .
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters . . . . . . . . .
Distribution Equipment—Ground Fault Monitor . .
Distribution Equipment—Substations. . . . . . . . . .
Distribution Equipment—Panels . . . . . . . . . . . . . .
Distribution Equipment—Transformers. . . . . . . . .

6
6
6
6
6
6
6

V1-T6-28
V1-T6-30
V1-T6-33
V1-T6-37
V1-T6-38
V1-T6-38
V1-T6-39
V1-T6-42
V1-T6-44
V1-T6-45
V1-T6-46
V1-T6-49
V1-T6-50

6
6

Newport Camp Mate Power Pedestal

6

Product Description

Features

The Newport Camp Mate
provides many of the features
and options of our other fullsize pedestals, but in a
compact self-contained unit.
This model provides more
mounting options to RV park
owners than any other model.
It can be mounted to our
stainless steel stand either
flanged or direct burial, a
post or any wall.

●

6
6
6
6
6
6
6
6
6

It comes standard with a resin
housing that will never rust or
deteriorate and provides area
lighting as well as aiding in
hooking up at night. This unit
is especially suitable to many
RV park renovation projects
as well as new RV parks.

6
6

●

●
●

●

●

●

Photocell controlled 7 watt
fluorescent light with
amber lens
Lockable weatherproof
door that protects
receptacles and breakers
Engineered resin housing
Limited lifetime warranty
on the housing
Designed to mount on a
post, wall or an optional
custom stand
Loop-feed 1/4-inch copper
stud lug busbars that can
accept 2/0 AWG wire for
Camp Mate without
optional stand
Loop-feed mechanical
busbars that can accept up
to 2/0 AWG wire for Camp
Mate on optional stand

Available Options
●

●

●

●
●
●

●

●

●

●

6

●

6

●

6

●

6

36-inch stainless
steel stand
40-inch stainless steel
pad-mounted stand
60-inch direct burial
stainless steel stand
Telephone (RJ-11)
Cable TV
High-speed Internet
connector (RJ-45)
Water—single or dual
1/4-turn brass ball valves
(brass “T” connection)
with 3/4-inch hose bibs
mounted on optional stand
Water—anti-siphon
backflow preventer
Loop feed 3/8-inch stud lug
copper busbar for up to
350 kcmil wire with stand
(recommended for salt
water environments)
Single-feed mechanical
busbars for up to 350 kcmil
wire available with stand
Digital electronic meter
Wireless remote reading of
electronic kilowatt meter
Meter socket available with
aluminum stands (to accept
glass style meter)

6
6
6
V1-T6-36

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Standards and Certifications
The Newport Camp Mate is
UL listed and comes with a
limited lifetime warranty on
the housing.

Power Pedestals
RV Park Hook-Ups

6.4

Catalog Number Selection

6
C A Y B U 4 3 0 1 1 2 W M

Type
N = NP Harbor Mate
C = NP Camp Mate

A
C
F
G
I
L
M
O
R
S
T
U
V
W
Y

Lighting and Lens Color
= 7W light
Amber
= 9W light
Amber
= No lighting
Amber
= 7W light
Clear
= 9W light
Clear
= No lighting
Clear
= 7W light
Special
= 9W light
Special
= No lighting
Special
= 350 MA LED Amber
= 700 MA LED Amber
= 350 MA LED Clear
= 700 MA LED Clear
= 350 MA LED Special
= 700 MA LED Special

Photocell
Y = Yes
N = No
Lighting Protection
B = Breaker protected
F = Fuse protected
Metering Type 1
U = Unmetered
D = Digital electronic meters
R = Receptacles metered
individually

Stand
0 =0
1 =1
Sides and
Receptacles
R1S1 R2S1 R3S1
0
0
0
1
1
1
2
2
3
3
4
4
0 = None
1 = 20A GFI duplex
2 = 30A, 125V
3 = 50A, 125V
4 = 50A, 125/250V

6
Bus
S = Single-phase 1/4-inch copper busbar
F = Three-phase 1/4-inch copper busbar
C = Single-phase 1/4-inch Canadian busbar
M = Mechanical lug 2/0
Q = Single-phase 1/4-inch split mechanical
busbar (with stand ONLY)
A = 1/4-inch Canadian mechanical

Water
Option 2
0 =0
1 =1
2 =2

6
6
6
6
6
6
6

Hard Wired
Breakers

6

S1
0 = None
2 = 20A, two-pole
3 = 30A

6
6

Phone Cable TV and Internet Options
Phone Jack
Cable TV Jack
Internet Option
A =
1
0
0
B =
1
0
1
C =
1
0
2
D =
1
1
0
E =
1
1
1 (Camp Mate only)
T =
0
0
1
V =
0
1
0
W=
0
1
1
0 =
0
0
0

6
6
6
6

Receptacle: R1 = Receptacle 1
R2 = Receptacle 2
R3 = Receptacle 3

6
6

Notes
1 20A GFIs not metered.
2 Number represents the quantity of 1/4-turn ball valves with 3/4-inch hose bibs (with stand only).

6
6
6
6
6
6
6
6
6
6
6
6

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-37

6.4
6
6

Power Pedestals
RV Park Hook-Ups

Accessories
See Page V1-T6-75.

Dimensions

6

Approximate Dimensions in Inches (mm)

6

Newport Camp Mate

6

0.12
(3.2)

0.12
(3.2)

9.18 (233.0)

9.18 (233.0)

6
6

10.38
(263.7)

10.38
(263.7)

6
6
6

7.44
(189.1)

10.52 (267.2)

7.44
(189.1)

10.52 (267.2)

6
15.28
(388.0)

6
6

14.53
(369.0)

14.53
(369.0)

13.63
(346.2)

12.88
(327.2)

6
6
6

4º

4º
10.38 (263.7)

10.38 (263.7)

9.59 (243.6)

6
6
6
6
6

1.54
(39.1) 4.02
(102.2)

2.37
(60.3)
1.68
(42.7)

6
6

1.68
(42.7)

3.40
(86.4)
6.70
(170.2)
Newport Redesign

1.54
(39.1) 4.02
(102.2)

2.37
(60.3)
3.40
(86.4)
6.70
(170.2)

Newport Redesign With Meters

6
6
6
6
6
6
6
V1-T6-38

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Power Pedestals
RV Park Hook-Ups

6.4

Contents

Park Light Power Pedestal

Description

Page

Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . .
Powerhouse Power Pedestal. . . . . . . . . . . . . . . . .
Powerhouse—Stainless Steel (SS) Power Pedestal
Newport Camp Mate Power Pedestal . . . . . . . . . .
Park Light Power Pedestal
Catalog Number Selection . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .
Firehouse. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters . . . . . . . . .
Distribution Equipment—Ground Fault Monitor . .
Distribution Equipment—Substations . . . . . . . . . .
Distribution Equipment—Panels . . . . . . . . . . . . . .
Distribution Equipment—Transformers . . . . . . . . .

V1-T6-28
V1-T6-30
V1-T6-33
V1-T6-36
V1-T6-40
V1-T6-41
V1-T6-41
V1-T6-42
V1-T6-44
V1-T6-45
V1-T6-46
V1-T6-49
V1-T6-50

6
6
6
6
6
6
6
6
6
6
6

Park Light Power Pedestal
Product Description

Features

The elegant design of the
Park Light complements park
landscaping and provides
essential lighting required
for park safety and security
for campground paths,
walkways, recreational areas
and even pools. The Park
Light has the same 360
degree lighting design as
the Powerhouse and a resin
housing that will never rust
or deteriorate.

●

At 10¢/kWH, it will provide
area lighting at a cost of
less than 50¢/month and
the bulbs will last for about
three years. The Park Light
is a perfect lighting fixture
for any campground and
especially for RV parks with
Powerhouse utility centers.

●

●

●

Photocell controlled dual
13 watt fluorescent light
with amber lens
Engineered resin
housing with a two-part
polyurethane coating for a
UV-resistant, long-lasting
finish
Limited lifetime warranty
on the housing
Loop-feed 1/4-inch stud lug
copper busbars that can
accept 2/0 AWG wire

Available Options
●
●

●
●
●

●

●

●
●

●

●

Clear lens
Photocell controlled single
or dual 7 watt or 13 watt
fluorescent light
Phone (RJ-11)
Cable TV
High-speed Internet
(RJ-45)
Water faucet(s) with
3/4-inch hose bib
Water—anti-siphon
backflow preventer
Digital electronic meter
Wireless remote reading of
electronic kilowatt meter
Direct burial ground
mounting stand
Custom paint color

Standards and Certifications
The housing has a limited
lifetime warranty, and the unit
is UL listed.

6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-39

6.4
6

Power Pedestals
RV Park Hook-Ups

Catalog Number Selection

H D Y B D 4 7 0 1 2 A M

6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Type
H = Hatteras Light
R = Park Light

A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
Y

Lighting and Lens Color
= 7W light
Amber
= Dual 7W light Amber
= 9W light
Amber
= 13W light
Amber
= Dual 13W light Amber
= No lighting
Amber
= 7W light
Clear
= Dual 7W light Clear
= 9W light
Clear
= 13W light
Clear
= Dual 13W light Clear
= No lighting
Clear
= 7W light
Special
= Dual 7W light Special
= 9W light
Special
= 13W light
Special
= Dual 13W light Special
= No lighting
Special
= 350 MA LED
Amber
= 700 MA LED
Amber
= 350 MA LED
Clear
= 700 MA LED
Clear
= 350 MA LED
Special
= 700 MA LED
Special

Photocell
Y = Yes
N = No
Lighting Protection
B = Breaker protected
F = Fuse protected
Metering Type 1
U = Unmetered
D = Digital electronic meters
R = Receptacles metered
individually

Sides and
Receptacles
R1S1 R2S1 R1S2
0
0
0
1
1
1
2
2
2
3
3
3
4
4
4
0 = None
1 = 20A GFI duplex
2 = 30A, 125V
3 = 50A, 125V
4 = 50A, 125/250V

Water Option 2
0 =0
1 = 1 (1/2-inch)
2 = 2 (1/2-inch)
3 = 1 (3/4-inch)
4 = 2 (3/4-inch)
Hard Wired
Breakers
S1
0 = None
2 = 20A, two-pole
3 = 30A

Bus
S = Single-phase 1/4-inch copper busbar
F = Three-phase 1/4-inch copper busbar
C = Single-phase 1/4-inch Canadian busbar
M = Mechanical lug 2/0
A = 1/4-inch Canadian mechanical
Phone Cable TV and Internet Options
Phone
Cable TV
Internet
Jack
Jack
Option
A = 1
0
0
B = 1
0
1
C = 1
0
2
D = 1
1
0
E = 1
1
1
F = 1
1
2
G = 1
2
0
H = 1
2
1
I = 1
2
2
J = 2
0
0
M= 2
1
0
P = 2
2
0
S = 0
2
2
T = 0
0
1
U = 0
0
2
V = 0
1
0
W= 0
1
1
X = 0
1
2
Y = 0
2
0
Z = 0
2
1

Receptacle: R1 = Receptacle 1, Side 1
R2 = Receptacle 2, Side 2
Notes
1 20A GFIs not metered.
2 Number represents the quantity of 1/4-turn ball valves with 3/4-inch hose bibs (with stand only).

6
6
6
6
6
6
6
6
6
6
6
6
6
V1-T6-40

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Power Pedestals
RV Park Hook-Ups

6.4

Accessories

6

See Page V1-T6-75.

6

Dimensions
Approximate Dimensions in Inches (mm)

6
6

Park Light

6
6
6
6
6
6

Busbar Access Top Removed

6

Inside Top

6

13.39
(340.2)

6
6
6
6
6
6
6
6
6

30.98
(786.9)

6
6
6
6
6
6
6
7.90 (200.7)

7.90 (200.7)

Side View

Front View

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

6
6
V1-T6-41

6.4
6

Power Pedestals
RV Park Hook-Ups

Contents

Firehouse

Description

6

Page

Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . .
Powerhouse Power Pedestal . . . . . . . . . . . . . . . .
Powerhouse—Stainless Steel (SS) Power Pedestal
Newport Camp Mate Power Pedestal . . . . . . . . .
Park Light Power Pedestal . . . . . . . . . . . . . . . . . .
Firehouse
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters . . . . . . . . .
Distribution Equipment—Ground Fault Monitor . .
Distribution Equipment—Substations. . . . . . . . . .
Distribution Equipment—Panels . . . . . . . . . . . . . .
Distribution Equipment—Transformers. . . . . . . . .

6
6
6
6
6
6
6

V1-T6-28
V1-T6-30
V1-T6-33
V1-T6-36
V1-T6-39
V1-T6-43
V1-T6-43
V1-T6-44
V1-T6-45
V1-T6-46
V1-T6-49
V1-T6-50

6
6

Firehouse

6

Product Description

6
6
6
6

The Firehouse is designed to
provide added fire safety to
RV parks and campgrounds.
The Firehouse provides a
convenient location and easy
access to fire extinguishers
and to an optional life ring
when installed around pools
and waterfront amenities.

6
6
6

Features
In addition, the Firehouse
provides area lighting for easy
identification during an
emergency and for security
lighting around the unit. The
Firehouse can be equipped
with an alarm strobe light and
siren, which are automatically
activated when the fire
extinguisher cabinet door is
opened or the optional life
ring is removed.

●

●

●

●

●

Available Options

Photocell controlled
13 watt fluorescent light
Amber lens for bug
reduction
10 lb ABC Type fire
extinguisher
Stainless steel housing
with oven-baked enamel
finish with an engineered
resin base and top
Limited lifetime warranty
on the housing

●

●

●

Alarm strobe light
and siren
Optional 24-inch white or
orange life ring for poolside
or dockside installations
20 lb ABC Type fire
extinguisher

Catalog Number Selection

F A Y A E N

6
6

Type
F = Firehouse
Photocell
Y = Yes
N = No

6
6
6

A
B
C
D
E
F
G
H

6
6
6

= 7W light
= Dual 7W light
= 9W light
= 13W light
= Dual 13W light
= No lighting
= 7W light
= Dual 7W light

Alarm/Strobe
A = Include alarm/strobe
N = No alarm/strobe

Amber
Amber
Amber
Amber
Amber
Amber
Clear
Clear

24-Inch Life Ring
R = Include life ring
N = No life ring

Fire Extinguisher
E = Include 10 lb extinguisher
N = No extinguisher
X = Include 20 lb extinguisher

Lighting and Lens Color
I = 9W light
Clear
J = 13W light
Clear
K = Dual 13W light Clear
L = No lighting
Clear
M = 7W light
Special
N = Dual 7W light Special
O = 9W light
Special
P = 13W light
Special

Q = Dual 13W light
R = No lighting
S = 350 MA LED
T = 700 MA LED
U = 350 MA LED
V = 700 MA LED
W = 350 MA LED
Y = 700 MA LED

Special
Special
Amber
Amber
Clear
Clear
Special
Special

6
6
6
V1-T6-42

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Power Pedestals
RV Park Hook-Ups

6.4

Accessories

6

See Page V1-T6-75.

6

Dimensions
Approximate Dimensions in Inches (mm)

6
6

Firehouse–SS

6
6
6
6
6
6
6
6
6
6

40.74
(1034.9)

6
6
6
6
6
6
6
6
6
6

9.88
(250.8)

6

11.54
(293.0)

6
6
6
6
6
Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-43

6.4
6

Power Pedestals
RV Park Hook-Ups

Contents

Digital Electronic Kilowatthour Meters

Description

6

Page

Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . .
Powerhouse Power Pedestal . . . . . . . . . . . . . . . .
Powerhouse—Stainless Steel (SS) Power Pedestal
Newport Camp Mate Power Pedestal . . . . . . . . .
Park Light Power Pedestal . . . . . . . . . . . . . . . . . .
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters
Distribution Equipment—Ground Fault Monitor . .
Distribution Equipment—Substations. . . . . . . . . .
Distribution Equipment—Panels . . . . . . . . . . . . . .
Distribution Equipment—Transformers. . . . . . . . .

6
6
6
6
6

V1-T6-28
V1-T6-30
V1-T6-33
V1-T6-36
V1-T6-39
V1-T6-42
V1-T6-45
V1-T6-46
V1-T6-49
V1-T6-50

6
6
6
6

Digital Electronic Kilowatthour Meters

6

Product Description

Features

Available Options

Using the latest surface
mount technology, Eaton
manufactures a digital
electronic kilowatt hour
meter that exceeds the
+/– 2% accuracy required by
ANSI (American National
Standards Institute) C-12.1
and is approved by the state
of California at +/– 1% over
the full range of 0–100A from
a 0.5 to 1 power factor and is
available for both single- and
three-phase applications.

Our meter is designed to
be user friendly in that all
connections from external
sources and the meter
output are through one
14-pin locking connector.
This feature eliminates many
common problems, such
as reverse line polarity and
improper coil polarity. Simple
LEDs, both red and green,
indicate line and load
condition and the pulsed
LED indicates the rate of
power consumption.

●

6
6
6
6
6
6
6
6
6
6
6
6

The meter drives an electromechanical counter that
requires a 12V pulse each
tenth of a kilowatthour,
providing 10 pulses per
kilowatt used. The meter
output can be hard wired or
connected to a transmitter
in the pedestal for wireless
transmission to a receiver
displaying the output on a
PC for direct billing of up to
1,000 individual customers

6
6
6

●
●
●
●

Wireless System
All of our meters are
“wireless capable” to allow
for wireless meter reading.
This technology enables the
marina or RV park to get
meter readings from one
central location rather than
visiting every site to read
the counters.
Meter Socket Capabilities
Meter sockets are available
on the Powerhouse and
Powerhouse–SS.
Standard:
●
Four jaw
●
Ring-type
●
100A

6
6
6
V1-T6-44

Product Selection

200A (SS only)
Lockable hasp
Ringless (SS only)
Five jaw
Seven jaw (SS only)

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

One Element Meter

Two Element Meter

Three Element Meter

Power Pedestals
RV Park Hook-Ups

6.4

Contents

Ground Fault Monitor

Description
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . .
Powerhouse Power Pedestal. . . . . . . . . . . . . . . . .
Powerhouse—Stainless Steel (SS) Power Pedestal
Newport Camp Mate Power Pedestal . . . . . . . . . .
Park Light Power Pedestal. . . . . . . . . . . . . . . . . . .
Firehouse. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters . . . . . . . . .
Distribution Equipment—Ground Fault Monitor
Distribution Equipment—Substations . . . . . . . . . .
Distribution Equipment—Panels . . . . . . . . . . . . . .
Distribution Equipment—Transformers . . . . . . . . .

Page
V1-T6-28
V1-T6-30
V1-T6-33
V1-T6-36
V1-T6-39
V1-T6-42
V1-T6-44
V1-T6-46
V1-T6-49
V1-T6-50

6
6
6
6
6
6
6
6
6
6

Distribution Equipment—Ground Fault Monitor

6

Product Description

Features

New to our product offering
are ground fault monitoring
systems designed to detect
fault currents in the AC shore
power system that are too
low to trip a circuit breaker.
The Ground Fault Monitor
helps reduce the risk of injury
or property damage, which
may result from stray fault
currents. Our ground fault
monitoring system provides
information to the
maintenance staff on the
overall condition of the AC
electrical system. The ground
fault monitoring system
operates 24 hours a day and
can be monitored by nontechnical personnel.

6

●

●

●

●
●

UL listed current
transformers
Adjustable trip level
10 mA to 10A
Current transformers up to
8 1/4-inch diameter
Visual and/or audible alarm
Housing of fiberglass or
powder coated stainless
steel available

6
6
6
6
6

Power Guard
The ground fault monitor
detects ground fault
currents by means of current
transformers (CT), which are
placed around main or branch
circuits. If a ground fault
occurs, the CT will detect the
amount of fault current and
send a signal to the ground
fault monitoring device where
the amount of fault current
is displayed with the faulty
circuit identified. The
detected fault can either
activate an indicator alarm or
disconnect the faulted circuit.

6
6
6
6
6
6
6
6
6
6
6
6
6

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-45

6.4
6

Power Pedestals
RV Park Hook-Ups

Contents

Substations

Description

6
6
6
6
6
6
6
6

Side-by-Side Substation

6
6

Distribution Equipment—Substations

6

Product Description

Application Description

The introduction of
substations into the marina
and recreational vehicle
market allows Eaton to be
your complete marina and
RV park electrical products
supplier. We are able to
assist in the design and
layout of your marina or RV
park electrical system from
the primary service provider
to your power pedestal. Our
substations are designed
for any coastal or inland
environment and are
constructed of powdercoated stainless steel
NEMA 3R housing cabinets.
All substation cabinets
come with our limited lifetime
warranty. All of our
substations use Eaton’s
panels and circuit breakers,
providing our customers the
utmost in circuit protection
and quality.

The aluminum and Galvaneal
cabinets are recommended
for inland applications.
The substations can be
configured with 50 to
330 kVA single-phase or
three-phase copper wound
transformers and up to 20
single-phase or 12 threephase branch breakers. An
optional three-sided doublewall cabinet is available that
provides air flow between the
panels. All substations come
standard with temperaturecontrolled cooling fans.

6
6
6
6
6
6
6
6
6
6
6
6

Page

Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . .
Powerhouse Power Pedestal . . . . . . . . . . . . . . . .
Powerhouse—Stainless Steel (SS) Power Pedestal
Newport Camp Mate Power Pedestal . . . . . . . . .
Park Light Power Pedestal . . . . . . . . . . . . . . . . . .
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters . . . . . . . . .
Distribution Equipment—Ground Fault Monitor . .
Distribution Equipment—Substations
Features, Benefits and Functions . . . . . . . . . .
Available Options . . . . . . . . . . . . . . . . . . . . . . .
Standards and Certifications . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .
Distribution Equipment—Panels . . . . . . . . . . . . . .
Distribution Equipment—Transformers. . . . . . . . .

Product Selection Guide
Panel and Transformer
Combinations
Panel

Transformer

Single-Phase
200A

50 kVA

300A

75 kVA

400A

100 kVA

600A

150 kVA

700A

167.5 kVA

800A

200 kVA

1000A

250 kVA

1200A

330 kVA

Three-Phase
100A

45 kVA

200A

75 kVA

300A

112.5 kVA

400A

150 kVA

600A

225 kVA

800A

300 kVA

6
6
6
6
6
6
V1-T6-46

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-28
V1-T6-30
V1-T6-33
V1-T6-36
V1-T6-39
V1-T6-42
V1-T6-44
V1-T6-45
V1-T6-47
V1-T6-48
V1-T6-48
V1-T6-48
V1-T6-49
V1-T6-50

Power Pedestals
RV Park Hook-Ups

6.4

Features, Benefits
and Functions
●

●

●

●

Limited lifetime warranty
on the housing
All stainless steel
hardware
Temperature controlled
cooling fans in the
transformer and circuit
breaker compartments
Lockable door

Ventilation
The substation ventilation
is designed to optimize air
circulation over and around
the transformers and through
the panel compartment so
that the substation operates
at lower temperatures.
Substations come equipped
with temperature-controlled
cooling fans for exhausting
hot air from the cabinet and
solar shield.

6
Substations

6

Temperature-controlled fans
for cooling

Stainless steel housing
with polyester
powder coating

6
6
6
6
6
6

Limited
lifetime
warranty
on the
housing

6
6

Stainless steel hardware with
locking doors

6
6
6

In addition, substations are
available with a doublewalled cabinet and solar
shield, which allow for
cooling of both the exterior
surface of the cabinet and
the internal components.

6
6
6
6
6
Custom made to your specifications:
Single-phase or three-phase copper
wound transformers
50 to 330 kVA

Up to 1200A main circuit breaker with
20 single-phase or 12 three-phase
branch circuit breakers

6
6

Sun Heat

6
6
6
Air

Transformers

6

Double-Walled
Stainless

6
6
6
6

Cool Air

6

Double-Walled Construction

6
Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-47

6.4
6

●

●

6
6

●

6
6
6

●

●

6

●

6

●

6

●

6
6

●

6
6
6
6
6

RV Park Hook-Ups

Available Options

6
6

Power Pedestals

●

●

Powder-coated cabinets
made of stainless steel
or fiberglass
Limited lifetime warranty
on housing. Transformer
and secondary distribution
panel in a single enclosure
have a one-year limited
warranty
Stainless steel housing
and hardware with
locking doors
Single-phase and threephase models
Overload capacity meets
ANSI L57.96–01.250
Optional double-walled
construction
Temperature-controlled
fans for cooling
Custom-made copper
wound single-phase or
three-phase transformers
from 50 to 330 kVA
Up to 1200A main circuit
breaker with 15 singlephase branch circuit
breakers or 10 three-phase
branch circuit breakers
Substations can be
equipped with photocells
to turn on and off lights
A 20A GFI can be installed
in the cabinet, as well
as a ground fault
monitoring system

Standards and Certifications
●

cULus listed

Dimensions
Approximate Dimensions in
Inches (mm)
Substations
Standard Substation
Height

53.00 (1346.2)

Width

51.00 (1295.4)

Depth

33.00 (838.2)

Side-by-Side Substation
Height

53.00 (1346.2)

Width

66.00 (1676.4)

Depth

30.00 (762.0)

Double Panel Substation
Height

53.00 (1346.2)

Width

63.00 (1600.2)

Depth

33.00 (838.2)

6
6
6
6
6
6
6
6
6
6
6
6
V1-T6-48

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Power Pedestals
RV Park Hook-Ups

6.4

Contents

Panels

Description

Page

Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . .
Powerhouse Power Pedestal. . . . . . . . . . . . . . . . .
Powerhouse—Stainless Steel (SS) Power Pedestal
Newport Camp Mate Power Pedestal . . . . . . . . . .
Park Light Power Pedestal. . . . . . . . . . . . . . . . . . .
Firehouse. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters . . . . . . . . .
Distribution Equipment—Ground Fault Monitor . .
Distribution Equipment—Substations . . . . . . . . . .
Distribution Equipment—Panels
Distribution Equipment—Transformers . . . . . . . . .

V1-T6-28
V1-T6-30
V1-T6-33
V1-T6-36
V1-T6-39
V1-T6-42
V1-T6-44
V1-T6-45
V1-T6-46
V1-T6-50

6
6
6
6
6
6
6
6
6
6
6

Distribution Equipment—Panels
Product Description

Features

We now can offer our
customers Eaton’s PRL-3A
and PRL-4 panels as standalone units or in one of our
substations. All of our busses
are made of copper and are
load rated, breakers are bolton type. Distribution panels
can be single-phase or threephase based on your system
requirements. Distribution
panels can also have a
main breaker or a main lug.
Branch circuit breakers
are provided based on
customer requirements.

●

●
●

All internal wiring is
fine stranded 2000V
insulated copper
Copper busbars
All exterior hardware is
stainless steel

Available Options
●
●

●

●

●
●

NEMA 3R or 4X
Powder-coated
stainless steel
Main breaker up to
1200A
Branch breaker 20 to
1200A
Main lug only
We also offer 480V
models—single-phase
and three-phase

Standards and Certifications
●
●

UL listed
cULus listed

6
6
6
6
6
6
6

Single-Phase
●
Up to 1200A main
circuit breakers
●
Up to 42 branch
circuit breakers

6
6
6

Three-Phase
●
Up to 1200A main
circuit breakers
●
Up to 42 branch
circuit breakers

6
6
6
6
6
6
6
6
6

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-49

6.4
6

Power Pedestals
RV Park Hook-Ups

Contents

Transformers

Description

6

Page

Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Selection Guide . . . . . . . . . . . . . . . . .
Powerhouse Power Pedestal . . . . . . . . . . . . . . . .
Powerhouse—Stainless Steel (SS) Power Pedestal
Newport Camp Mate Power Pedestal . . . . . . . . .
Park Light Power Pedestal . . . . . . . . . . . . . . . . . .
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters . . . . . . . . .
Distribution Equipment—Ground Fault Monitor . .
Distribution Equipment—Substations. . . . . . . . . .
Distribution Equipment—Panels . . . . . . . . . . . . . .
Distribution Equipment—Transformers

6
6
6
6
6
6

V1-T6-28
V1-T6-29
V1-T6-30
V1-T6-33
V1-T6-36
V1-T6-39
V1-T6-42
V1-T6-44
V1-T6-45
V1-T6-46
V1-T6-49

6
6
6

Distribution Equipment—Transformers

6

Product Description

Features

Because of the high humidity
and corrosive conditions of
coastal environments, our
transformers are wound with
Class H heavily insulated
copper bar and are double
dipped in tough insulating
varnish that protects the
copper, as well as reduces
the hum that is typical in
a transformer that is not
double dipped. For marine
applications, we provide
a third overcoat of high
temperature epoxy to protect
against the severe saltwater
environment. We can provide
this transformer in singlephase, from 50–500 kVA,
and three-phase, from
45–300 kVA.

●

6
6
6
6
6
6
6
6
6
6

●
●

●

Copper wound transformer
coils double dipped in high
temperature baking varnish
Copper terminations
Marine transformers with
epoxy overcoat
All copper-to-copper
connections

Available Options
●
●
●

Single-phase: 50–500 kVA
Three-phase: 45–300 kVA
Epoxy overcoat for nonmarine applications

Primary Voltages
●
480 wye three-phase
●
480V three-phase delta
three-wire + ground
●
480V single-phase
two-wire + ground
Secondary Voltages
●
127/220V three-phase
wye four-wire
●
120/208V three-phase
wye four-wire
●
120/240V single-phase
three-wire
Marina Power Distribution
Transformer kVA Availabilities
●
Single-phase: 50, 75, 100,
150, 167.5, 200, 250, 330,
500 kVA
●
Three-phase: 45, 75, 112.5,
150, 225, 300 kVA

6
6
6
6
6
6
6
6
V1-T6-50

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Standards and Certifications
●

cULus listed

Power Pedestals
Marina Power and Lighting Equipment

6.5

Contents

Marina Power and Lighting Equipment

Description

High-Quality, Weatherproof Electrical Equipment

Power Pedestals
Product Selection Guide. . . . . . . . . . . . . . . . . .
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . .
Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . .
Hatteras Light . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mariner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters . . . . . . . . .
Distribution Equipment—Ground Fault Monitor . .
Distribution Equipment—Mega Yacht Powerpoint
Distribution Equipment—Substations . . . . . . . . . .
Distribution Equipment—Panels . . . . . . . . . . . . . .
Distribution Equipment—Transformers . . . . . . . . .

Page
V1-T6-52
V1-T6-54
V1-T6-58
V1-T6-62
V1-T6-65
V1-T6-69
V1-T6-73
V1-T6-79
V1-T6-80
V1-T6-81
V1-T6-82
V1-T6-83
V1-T6-86
V1-T6-89
V1-T6-90

Learn
Online

6
6
6
6
6
6
6
6
6
6
6
6
6
6

Power Pedestals

6

Product Overview
Known as a leader in
electrical control, power
distribution, and industrial
automation products and
services, Eaton is a quality
driven company that
constantly looks for ways to
provide enhanced product
and service solutions for their
customers. Eaton will be able
to provide Marina developers
a complete electrical solution.
For more information on
the other products available
from Eaton, visit us online
at www.eaton.com or
www.marinapower.com.

What Eaton has to Offer
●
Eaton has more marina
power outlets in service
than all other suppliers
combined
●
We offer complementary
comprehensive in-house
electrical designs for
your complete marina
development using all high
quality Eaton products
●
We can provide your
marina development with
complete remote wireless
digital electronic meter
reading
●
Not only can Eaton provide
your marina with the
highest quality power
pedestals and marine
distribution equipment, we
can also supply your entire
electrical needs for your
surrounding development
and beyond from safety
switches to loadcenters
and much more

6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-51

6.5
6
6

Power Pedestals
Marina Power and Lighting Equipment

Product Selection Guide

Power Pedestal Quick Guide

6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Newport
Hatteras Light Harbor Mate

Lighthouse

Lighthouse–SS

Admiral–SS

Firehouse

Mariner

Lookout

Power Point

Main housing

Engineered resin

Stainless steel

Engineered resin

Engineered resin

Stainless steel

Stainless steel

Engineered resin

Stainless steel

Stainless steel

Top

Engineered resin

Engineered resin

Engineered resin

Engineered resin

Stainless steel

Engineered resin

Engineered resin

Stainless steel

Stainless steel

Optional stand

—

—

—

Stainless steel

—

—

PVC

—

—

External hardware

Stainless steel

Stainless steel

Stainless steel

Stainless steel

Stainless steel

Stainless steel

Stainless steel

Stainless steel

Stainless steel

Standard lightwattage(s)

13W

13W

13W

7W

13W

13W

5W, 7W & 13W

—

13W
Yes

LED lighting option

Yes

Yes

Yes

No

Yes

Yes

No

No

Photocell

Yes

Yes

Yes

Yes

Yes

Yes

No

No

Yes

Lockable doors

Yes

Yes

Yes

Yes

Yes

—

—

—

Yes

Hose hangers

Yes

Yes

No

No

Yes

No

No

No

No

Electric meters

Yes—up to 4

Yes—up to 4

Yes—up to 2

Yes—up to 2

Yes—up to 4

No

No

No

Yes—up to 6

Remote meter reading

Yes

Yes

Yes

Yes

Yes

No

No

No

Yes

Water

Two 3/4”

Two 3/4”

Two 1/2”

Two 3/4”

Two 3/4”

None

None

None

One 3/4” or more

Water meters

Yes

Yes

No

Yes

Yes

No

No

No

Yes

Telephone

Yes

Yes

Yes

Yes

Yes

No

No

No

Yes

Cable TV

Yes

Yes

Yes

Yes

Yes

No

No

No

Yes

Internet

Yes

Yes

Yes

Yes

Yes

No

No

No

Yes

Fire extinguisher

No

No

No

No

No

Yes—up to 20 lbs

No

No

No

Life ring

No

No

No

No

No

Yes—24”

No

No

No

Alarm and strobe light

No

No

No

No

No

Yes

No

No

No

20A 110V GFI

Yes

Yes

Yes

Yes

Yes

No

No

No

Yes

30A 125V twist—lock

Yes

Yes

Yes

Yes

Yes

No

No

No

Yes
Yes

50A 125/250V twist—lock

Yes

Yes

Yes

Yes

Yes

No

No

No

100A 120/240V pin and sleeve

Yes

Yes

No

No

Yes

No

No

No

Yes

100A 120/208V pin and sleeve

Yes

Yes

No

No

Yes

No

No

No

Yes

100A 277/480V pin and sleeve

Yes

Yes

No

No

Yes

No

No

No

Yes

100A 480V pin and sleeve

Yes

Yes

No

No

Yes

No

No

No

Yes

200A 480V pin and sleeve

No

No

No

No

Yes

No

No

No

Yes

Hardwire compatible

No

No

No

No

No

No

No

No

Yes
Yes

TVSS compatible

Yes

Yes

No

No

Yes

No

No

No

Card swipe compatible

Yes

Yes

No

Yes

Yes

No

No

No

Yes

Security camera compatible

No

No

No

No

No

No

No

Yes

No
Up to 800A

Busbar rating

Up to 500A

Up to 500A

Up to 140A

Up to 140A

Up to 500A

—

—

—

Maximum wire size—single feed

350 kcmil

350 kcmil

#2/0

#2/0

350 kcmil

—

—

—

(3) 500 kcmil

Maximum wire size—loop feed

#4/0

#4/0

#1

#1

350 kcmil

—

—

—

(3) 500 kcmil

Height

44”

40”

30”

36”

48”

43.5”

24” to 72”

72” to 96”

50”

Width

13.75”

9.875”

7.5”

10.5”

14”

9.875”

7”

9”

50”

Depth

13.75”

9.875”

7.5”

14.5”

14”

9.875”

7”

9”

36”

6

Warranty
Housing

Limited lifetime

Limited lifetime

Limited lifetime

Limited lifetime

Limited lifetime Limited lifetime

Limited lifetime

Limited lifetime Limited lifetime

6

Receptacles and breakers

2 years

2 years

2 years

2 years

2 years

—

—

—

2 years

Lighting assembly

1 year

1 year

1 year

1 year

1 year

1 year

1 year

—

1 year

6
6
6
V1-T6-52

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Power Pedestals
Marina Power and Lighting Equipment

Receptacles

Receptacle Configuration Availability

Side One
None

6.5

Lighthouse

Side Two
None

None

Lighthouse–SS

Admiral–SS

None

Receptacle Available with GFI Receptacles

Hatteras Light

Newport
Harbor Mate

30A

None

None

None

Yes

Yes

Yes

Yes

Yes

30A

30A

None

None

Yes

Yes

Yes

Yes

Yes

30A

None

30A

None

Yes

Yes

Yes

No

Yes

30A

30A

30A

30A

Yes

Yes

Yes

Yes

No

30A

50A

None

None

Yes

Yes

Yes

No

No

30A

None

50A

None

Yes

Yes

Yes

No

Yes

30A

50A

30A

50A

Yes

Yes

Yes

Yes 1

No

50A

None

None

None

Yes

Yes

Yes

No

No

50A

50A

None

None

Yes

Yes

Yes

Yes

Yes

50A

None

50A

None

Yes

Yes

Yes

No

Yes

50A

50A

50A

50A

Yes

Yes

Yes

No

No

100A 120/240V

None

None

None

Yes

Yes

Yes

No

No

100A 120/240V

None

50A-50A

None

Yes

Yes

Yes

No

No

100A 120/240V

None

100A 120/240V

None

Yes

Yes

Yes

No

No

100A 120/240V

50A-50A

100A 120/240V

50A-50A

Yes

Yes

Yes

No

No

100A 120/208V

None

None

None

No

No

Yes

No

No

100A 120/208V

None

100A 120/240V

None

Yes

Yes

Yes

No

No

100A 120/240V

100A 120/240V

100A 120/240V

100A 120/240V

Yes

Yes

Yes

No

No

100A 120/208V

100A 120/208V

100A 120/208V

100A 120/208V

No

No

Yes

No

No

100A 120/240V

100A 120/240V

100A 120/208V

100A 120/208V

No

No

Yes

No

No

No

No

Yes

No

No

6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Note
1 Configuration available with no additional GFI receptacles.

6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-53

6.5
6

Power Pedestals
Marina Power and Lighting Equipment

Contents

Lighthouse

Description

6

Power Pedestals. . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse
Available Options. . . . . . . . . . . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . .
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . .
Hatteras Light. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mariner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters . . . . . . . . . .
Distribution Equipment—Ground Fault Monitor. . .
Distribution Equipment—Mega Yacht Powerpoint .
Distribution Equipment—Substations . . . . . . . . . .
Distribution Equipment—Panels . . . . . . . . . . . . . .
Distribution Equipment—Transformers . . . . . . . . .

6
6
6
6
6
6
6
6
6
6
6
6

Lighthouse

6

Product Description

6
6
6
6
6
6
6
6
6
6

One of our most popular
units, the all-purpose
Lighthouse® pedestal has a
wide range of features. With
units in service around the
world, this stylish power
pedestal is recognized for its
practicality and exceptional
durability.
Engineered to withstand
the most severe weather
conditions, Lighthouse
power pedestals can be
found in marinas from
Alaska to the tropics.
Note: Custom paint color.
Note: Wireless remote reading
of electronic kilowatt meters.

Features, Benefits
and Functions
●

●

●
●

●

●

Note: Clear lens.
●

6

Photocell controlled
13 watt fluorescent light
(clear lens or amber lens
for bug reduction)
Lockable weatherproof
doors that protect breakers
and receptacles while in
use (a requirement of NFPA
303 and NEC Article 555)
Hose and cable brackets
Heavy resin housing with
a two-part polyurethane
coating for a UV-resistant,
long-lasting finish
Copper busbar with ratings
from 250 to 500A
New “hingeless” base
providing easy access for
both installation and
maintenance
Backlit faceplate for easy
receptacle plug-in at night

6
6
6
6
V1-T6-54

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Page
V1-T6-51
V1-T6-55
V1-T6-56
V1-T6-57
V1-T6-57
V1-T6-58
V1-T6-62
V1-T6-65
V1-T6-69
V1-T6-73
V1-T6-79
V1-T6-80
V1-T6-81
V1-T6-82
V1-T6-83
V1-T6-86
V1-T6-89
V1-T6-90

Power Pedestals
Marina Power and Lighting Equipment

Lighthouse

6.5

Available Options
●

360° controlled 13 watt fluorescent light
with amber lens for bug reduction

●
●

Digital electronic metering for each side
Lockable weatherproof doors that protect
breakers and receptacles

6

Digital electronic metering
(one, two or three element
meters available)
Built-in meter socket
20A/125V GFI receptacle
(max. of two GFI
receptacles per pedestal)

6
6
6

Note: 20A GFI receptacles are
not to be used for shore power.

Receptacle configuration available
30A, 50A, 30A/30A, 30A/50A,
50A/50A, 100A, Empty
Note: Custom configurations also available

●

●

Hose and cable brackets
●

1/4-inch Resin housing with a two-part
polyurethane coating for a UV resistant,
long-lasting finish
20A/125V GFI receptacle

●

Phone and cable TV connections
High-speed Internet connections (RJ45) for
each side

●

●

●

●
●
●

6
6

High-speed Internet
connections
Wireless remote metering
for electric and water
Transient voltage surge
suppressor (TVSS) to
protect from voltage
surges, spikes or lightning
on the AC power line
(extends warranty on
internal parts to three
years)
Stainless steel door hinge
on receptacle main doors
Single or dual steel 1/4-turn
ball valves with 3/4-inches
Hose bibs and stainless
steel handles
Single or dual phone and/or
cable TV connections
Base cap
Base extension
LED lighting

6
6
6
6
6
6
6
6
6
6
6
6

Copper Busbar with Ratings
from 250 to 500A

6

Cable and Internet
Connections

6
6
6
6

New Hingeless Base

6
Optional Meter Socket

6
6
6
6
6
6

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-55

6.5

Marina Power and Lighting Equipment

Catalog Number Selection

L D U 4 7 0 0 0 0 0 0 1 2 K M

6
6

Type
L = Lighthouse
S = LHSS

6
6
6
6
6

Metering Type
U = Unmetered
D = Digital electronic meters
(side one)
T = Digital electronic meters
(side two)
B = Digital electronic meters
(both sides)
R = Receptacles metered
individually
M = One meter socket
(100A)
N = Two meter socket
(100A each)
V = 200A meter socket

6
6
6
6
6
6
6
6
6
6

0
1
2
3
4
5
6
7
8
0
1
2
3
4
5
6
7
8

0
0
0
1
1
1
2
2
2
3
3
3
4
4
4
5
5
5
6
6
6
7
7
7
8
8
8
= None
= 20A GFI duplex
= 30A, 125V
= 50A, 125V
= 50A, 125/250V
= 100A, 208V
= 100A, 250V
= 100A, 277/480V
= 100A, 480V

R4S2

6

R3S2

6

Sides and Receptacles
R2S2

6

R1S2

6

Lighting and Lens Color
= 7W light
Amber
= Dual 7W light Amber
= 9W light
Amber
= 13W light
Amber
= Dual 13W light Amber
= No lighting
Amber
= 7W light
Clear
= Dual 7W light Clear
= 9W light
Clear
= 13W light
Clear
= Dual 13W light Clear
= No lighting
Clear
= 7W light
Special
= Dual 7W light Special
= 9W light
Special
= 13W light
Special
= Dual 13W light Special
= No lighting
Special
= 350 MA LED
Amber
= 700 MA LED
Amber
= 350 MA LED
Clear
= 700 MA LED
Clear
= 350 MA LED
Special
= 700 MA LED
Special

R4S1

A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
Y

R2S1

6

R1S1

6

R3S1

6

Power Pedestals

0
1
2
3
4
5
6
7
8

0
1
2
3
4
5
6
7
8

0
1
2
3
4
5
6
7
8

0
1
2
3
4
5
6
7
8

0
1
2
3
4
5
6
7

Water Option 1
=0
=1
=2
= Single water meter
= Dual water meter
= Single meter, 2V
= 1 frost free
= 2 frost free
Extra Unmetered GFI
Receptacles 2
0 = None
1 =1
2 =2

Phone Cable TV and Internet Options
Phone
Cable TV
Internet
Jack
Jack
Option
A = 1
0
0
B = 1
0
1
C = 1
0
2
D = 1
1
0
E = 1
1
1
F = 1
1
2
G = 1
2
0
H = 1
2
1
I = 1
2
2
J = 2
0
0
K = 2
0
1
L = 2
0
2
M= 2
1
0
N = 2
1
1
O = 2
1
2
P = 2
2
0
Q = 2
2
1
R = 2
2
2
S = 0
2
2
T = 0
0
1
U = 0
0
2
V = 0
1
0
W= 0
1
1
X = 0
1
2
Y = 0
2
0
Z = 0
2
1
0 = 0
0
0
Bus
S = Single-phase 3/8-inch copper busbar
F = Three-phase 3/8-inch copper busbar
C = Single-phase 3/8-inch Canadian busbar
T = Three-phase 3/8-inch Canadian busbar
M = Single-phase 300 kcmil mechanical lug bus
Z = Three-phase 300 kcmil mechanical lug bus
L = Single-phase 350 kcmil mechanical lug bus
P = Three-phase 350 kcmil mechanical lug bus
N = Single-phase 1/4-inch copper busbar
Q = Single-phase 1/4-inch split mechanical busbar

Receptacle: R1S1 = Receptacle 1, Side 1
R2S1 = Receptacle 2, Side 1
R1S2 = Receptacle 1, Side 2
R2S2 = Receptacle 2, Side 2
Notes
1 Number represents the quantity of 1/4-turn ball valves with 3/4-inch hose bibs.
2 Quantity of 20A GFI duplex receptacles.

6
6
6
6
6
6
V1-T6-56

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Power Pedestals
Marina Power and Lighting Equipment

6.5

Accessories

6

See Page V1-T6-75.

6

Dimensions
Approximate Dimensions in Inches (mm)

6
6

Lighthouse

6
6
6
6
6
6

Top

6

44.00
(1117.6)

6
6
6
6
6
6
6
6

Front View

Side View

6
6
6
6
6
6
6
13.75
(249.3)

6
6

Broken View

6
6
Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-57

6.5
6

Power Pedestals
Marina Power and Lighting Equipment

Contents

Lighthouse–SS

Description

6

Power Pedestals. . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse–SS
Available Options. . . . . . . . . . . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . .
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . .
Hatteras Light. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mariner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters . . . . . . . . . .
Distribution Equipment—Ground Fault Monitor. . .
Distribution Equipment—Mega Yacht Powerpoint .
Distribution Equipment—Substations . . . . . . . . . .
Distribution Equipment—Panels . . . . . . . . . . . . . .
Distribution Equipment—Transformers . . . . . . . . .

6
6
6
6
6
6
6
6
6
6
6
6

Lighthouse–SS

6

Product Description

6
6
6
6

The Lighthouse–SS offers
the same standard features
and available options as the
standard Lighthouse. But,
like all of the stainless steel
products manufactured here,
the Lighthouse–SS is made
with high-quality 316L
stainless steel for superior
quality and performance.

Features, Benefits
and Functions
●

●

●
●

6

Note: 20/125A GFI receptacle.

6

Note: Wireless remote reading
of electronic kilowatt meters.

●

6

Note: Clear lens.

●

6
6
6
6
6
6

Note: Meter socket for each
side powered (to accept glass
style meter).
Note: Receptacle configurations
available:
30A
30A/30A
30A/50A
50A/50A
100A (single-phase) 120/240V
100A (three-phase) 120/208V
200A (three-phase) 480V

●

Photocell controlled
13 watt fluorescent light
(clear lens or amber lens
for bug reduction)
Available with lockable
weatherproof doors
Hose and cable brackets
Long-lasting maintenancefree 316L stainless steel
housing with limited
lifetime warranty
Copper busbar with ratings
from 250 to 500A
Large removable
access panel for easy
maintenance and
installation
Backlit faceplate for easy
receptacle plug-in at night

6
6
V1-T6-58

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Page
V1-T6-51
V1-T6-54
V1-T6-59
V1-T6-60
V1-T6-61
V1-T6-61
V1-T6-62
V1-T6-65
V1-T6-69
V1-T6-73
V1-T6-79
V1-T6-80
V1-T6-81
V1-T6-82
V1-T6-83
V1-T6-86
V1-T6-89
V1-T6-90

Power Pedestals
Marina Power and Lighting Equipment

Lighthouse–SS

6.5

Available Options
●

360° controlled 13 watt
fluorescent light with amber
lens for bug reduction

●

Digital electronic metering
for each side

Note: 20A GFI receptacles are
not to be used for shore power.

Powder-coated stainless steel
weatherproof doors that protect
receptacles and breakers

●

Lockable doors

●

Hose and cable bracket
Long-lasting maintenance-free
powder-coated stainless steel
housing with limited lifetime
warranty

●

High-speed Internet connection
(RJ-45)
for each side
●

Large removable access panel
for easy maintenance and
installation

●

●

6

Digital electronic metering
(one, two or three element
meters available)
20A/125V GFI receptacle
(max. of two GFI
receptacles per pedestal)

6
6
6
6

High-speed Internet
connection
Wireless remote metering
available for water and
electricity
Transient voltage surge
suppressor (TVSS) to
protect from voltage
surges, spikes or lightning
on the AC power line
(extends warranty on
internal parts to three
years)
Single or dual phone and/or
cable TV connections
Single or dual 3/4-inch hose
bibs with stainless steel
Handles LED lighting

6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Phone and Cable TV Connections

6

New Door

6
6
6
6
6
Copper Busbar with Ratings
from 250 to 500A

6

Backlit Faceplate to Aid
in Hooking Up at Night

6
6

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-59

6.5

Marina Power and Lighting Equipment

Catalog Number Selection

L D U 4 7 0 0 0 0 0 0 1 2 K M

6
6

Type
L = Lighthouse
S = LHSS

6
6
6
6
6

Metering Type
U = Unmetered
D = Digital electronic meters
(side one)
T = Digital electronic meters
(side two)
B = Digital electronic meters
(both sides)
R = Receptacles metered
individually
M = One meter socket
(100A)
N = Two meter socket
(100A each)
V = 200A meter socket

6
6
6
6
6
6
6
6
6
6

0
1
2
3
4
5
6
7
8
0
1
2
3
4
5
6
7
8

0
0
0
1
1
1
2
2
2
3
3
3
4
4
4
5
5
5
6
6
6
7
7
7
8
8
8
= None
= 20A GFI duplex
= 30A, 125V
= 50A, 125V
= 50A, 125/250V
= 100A, 208V
= 100A, 250V
= 100A, 277/480V
= 100A, 480V

R4S2

6

R3S2

6

Sides and Receptacles
R2S2

6

R1S2

6

Lighting and Lens Color
= 7W light
Amber
= Dual 7W light Amber
= 9W light
Amber
= 13W light
Amber
= Dual 13W light Amber
= No lighting
Amber
= 7W light
Clear
= Dual 7W light Clear
= 9W light
Clear
= 13W light
Clear
= Dual 13W light Clear
= No lighting
Clear
= 7W light
Special
= Dual 7W light Special
= 9W light
Special
= 13W light
Special
= Dual 13W light Special
= No lighting
Special
= 350 MA LED
Amber
= 700 MA LED
Amber
= 350 MA LED
Clear
= 700 MA LED
Clear
= 350 MA LED
Special
= 700 MA LED
Special

R4S1

A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
Y

R2S1

6

R1S1

6

R3S1

6

Power Pedestals

0
1
2
3
4
5
6
7
8

0
1
2
3
4
5
6
7
8

0
1
2
3
4
5
6
7
8

0
1
2
3
4
5
6
7
8

0
1
2
3
4
5
6
7

Water Option 1
=0
=1
=2
= Single water meter
= Dual water meter
= Single meter, 2V
= 1 frost free
= 2 frost free
Extra Unmetered GFI
Receptacles 2
0 = None
1 =1
2 =2

Phone Cable TV and Internet Options
Phone
Cable TV
Internet
Jack
Jack
Option
A = 1
0
0
B = 1
0
1
C = 1
0
2
D = 1
1
0
E = 1
1
1
F = 1
1
2
G = 1
2
0
H = 1
2
1
I = 1
2
2
J = 2
0
0
K = 2
0
1
L = 2
0
2
M= 2
1
0
N = 2
1
1
O = 2
1
2
P = 2
2
0
Q = 2
2
1
R = 2
2
2
S = 0
2
2
T = 0
0
1
U = 0
0
2
V = 0
1
0
W= 0
1
1
X = 0
1
2
Y = 0
2
0
Z = 0
2
1
0 = 0
0
0
Bus
S = Single-phase 3/8-inch copper busbar
F = Three-phase 3/8-inch copper busbar
C = Single-phase 3/8-inch Canadian busbar
T = Three-phase 3/8-inch Canadian busbar
M = Single-phase 300 kcmil mechanical lug bus
Z = Three-phase 300 kcmil mechanical lug bus
L = Single-phase 350 kcmil mechanical lug bus
P = Three-phase 350 kcmil mechanical lug bus
N = Single-phase 1/4-inch copper busbar
Q = Single-phase 1/4-inch split mechanical busbar

Receptacle: R1S1 = Receptacle 1, Side 1
R2S1 = Receptacle 2, Side 1
R1S2 = Receptacle 1, Side 2
R2S2 = Receptacle 2, Side 2
Notes
1 Number represents the quantity of 1/4-turn ball valves with 3/4-inch hose bibs.
2 Quantity of 20A GFI duplex receptacles.

6
6
6
6
6
6
V1-T6-60

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Power Pedestals
Marina Power and Lighting Equipment

6.5

Accessories

6

See Page V1-T6-75.

6

Dimensions
Approximate Dimensions in Inches (mm)

6
6

Lighthouse–SS

6
6
6
6
6
6
6
6
6
6

40.00
(1016.0)

6
6
6
6
6
6
6
6
6
6

9.88
(251.0)

6
6
6
6
6
6
Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-61

6.5
6

Power Pedestals
Marina Power and Lighting Equipment

Contents

Admiral–SS

Description

6

Power Pedestals. . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Admiral–SS
Catalog Number Selection . . . . . . . . . . . . . . . .
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . .
Hatteras Light. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mariner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters . . . . . . . . . .
Distribution Equipment—Ground Fault Monitor. . .
Distribution Equipment—Mega Yacht Powerpoint .
Distribution Equipment—Substations . . . . . . . . . .
Distribution Equipment—Panels . . . . . . . . . . . . . .
Distribution Equipment—Transformers . . . . . . . . .

6
6
6
6
6
6
6
6
6
6
6
6

Admiral–SS

6

Product Description

Features

Truly the flagship of our
unitized pedestal line, the
Admiral–SS possesses
amperage capabilities up to
500A and voltages of 480/277
three-phase, 120/240 singlephase and combinations of
these receptacles all in one
unit to serve nearly any size
Mega Yacht.

●

6
6
6
6
6

●

Heavy 316L stainless
steel housing that is
powder coated with a
polyester resin
Photocell controlled
13 watt fluorescent light
with clear lens that
provides 360 degrees
of lighting

Available Options
●

●

●
●

6
6

●

6

Dual phone and/or cable TV
connections
Four 100A receptacles
of any two voltage
combinations such as
277/480 three-phase,
120/208 three-phase or
120/240 single-phase
200A/480V receptacles
when the 100A 120/240V
receptacles are used, two
50A 120/240V receptacles
can also be provided for a
total of 500A
20A/125V GFI receptacle
(max. of two GFI
receptacles per pedestal)

Note: 20A GFI receptacles are not
to be used for shore power.

6

●

6
6

●

6
6

●
●

6
●

6
V1-T6-62

Single or dual Cat5
high-speed Internet
connections
Single or dual water
1/4-turn ball valves with
3/4-inch hose bibs and
stainless steel handles
Digital metering available
Wireless remote metering
available for water and
electricity
LED lighting

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Page
V1-T6-51
V1-T6-54
V1-T6-58
V1-T6-63
V1-T6-64
V1-T6-64
V1-T6-65
V1-T6-69
V1-T6-73
V1-T6-79
V1-T6-80
V1-T6-81
V1-T6-82
V1-T6-83
V1-T6-86
V1-T6-89
V1-T6-90

Power Pedestals
Marina Power and Lighting Equipment

6.5

Catalog Number Selection

6

A D U 4 7 0 0 0 0 0 0 1 2 K M
Type
A = Admiral–SS
Lighting and Lens Color
A = 7W light
Amber
B = Dual 7W light
Amber
C = 9W light
Amber
D = 13W light
Amber
E = Dual 13W light Amber
F = No lighting
Amber
G = 7W light
Clear
H = Dual 7W light
Clear
I = 9W light
Clear
J = 13W light
Clear
K = Dual 13W light Clear
L = No lighting
Clear
M = 7W light
Special
N = Dual 7W light
Special
O = 9W light
Special
P = 13W light
Special
Q = Dual 13W light Special
R = No lighting
Special
S = 350 MA LED
Amber
T = 700 MA LED
Amber
U = 350 MA LED
Clear
V = 700 MA LED
Clear
W = 350 MA LED
Special
Y = 700 MA LED
Special

R3S2

R4S2

0
0
0
1
1
1
2
2
2
3
3
3
4
4
4
5
5
5
6
6
6
7
7
7
8
8
8
None
20A GFI duplex
30A, 125V
50A, 125V
50A, 125/250V
100A, 208V
100A, 250V
100A, 277/480V
100A, 480V

R2S2

0
1
2
3
4
5
6
7
8
0 =
1 =
2 =
3 =
4 =
5 =
6 =
7 =
8 =

R1S2

R4S1

R3S1

R2S1

Metering Type
U = Unmetered
D = Digital electronic meters
(side one)
T = Digital electronic meters
(side two)
B = Digital electronic meters
(both sides)
M = One meter socket
(100A)
N = Two meter socket
(100A each)
V = 200A meter socket

R1S1

Sides and Receptacles

0
1
2
3
4
5
6
7
8

0
1
2
3
4
5
6
7
8

0
1
2
3
4
5
6
7
8

0
1
2
3
4
5
6
7
8

0
1
2
3
4
5

Water Option 1
=0
=1
=2
= Single water meter
= Dual water meter
= Single meter, 2V
Extra Unmetered GFI
Receptacles
0 = None
1 =1
2 =2

6
6

Phone Cable TV and Internet Options
Phone
Cable TV
Internet
Jack
Jack
Option 2
A = 1
0
0
B = 1
0
1
C = 1
0
2
D = 1
1
0
E = 1
1
1
F = 1
1
2
G = 1
2
0
H = 1
2
1
I = 1
2
2
J = 2
0
0
K = 2
0
1
L = 2
0
2
M = 2
1
0
N = 2
1
1
O = 2
1
2
P = 2
2
0
Q = 2
2
1
R = 2
2
2
S = 0
2
2
T = 0
0
1
U = 0
0
2
V = 0
1
0
W= 0
1
1
X = 0
1
2
Y = 0
2
0
Z = 0
2
1
0 = 0
0
0

6
6
6
6
6
6
6
6
6
6
6

Bus
S = Single-phase 3/8-inch copper busbar
F = Three-phase 3/8-inch copper busbar
C = Single-phase 3/8-inch Canadian busbar
T = Three-phase 3/8-inch Canadian busbar
M = Single-phase 300 kcmil mechanical lug bus
Z = Three-phase 300 kcmil mechanical lug bus
L = Single-phase 350 kcmil mechanical lug bus
P = Three-phase 350 kcmil mechanical lug bus
N = Single-phase 1/4-inch copper busbar
Q = Single-phase 1/4-inch split mechanical busbar
D = Dual-phase busbar

6
6
6
6
6
6

Receptacles: R1S1 = Receptacle 1, Side 1
R2S1 = Receptacle 2, Side 1
R3S1 = Receptacle 3, Side 1
R4S1 = Receptacle 3, Side 1
R1S2 = Receptacle 1, Side 2
R2S2 = Receptacle 2, Side 2
R3S2 = Receptacle 3, Side 2
R4S2 = Receptacle 3, Side 2

6
6
6
6

Notes
1 Number represents the quantity of 1/4-turn ball valves with 3/4-inch hose bibs.
2 Number represents the quantity of RJ-45 high-speed Internet jacks.

6

Internet option also available. Contact factory for details.

6
6
6
6
6

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-63

6.5
6
6

Power Pedestals
Marina Power and Lighting Equipment

Accessories
See Page V1-T6-75.

Dimensions

6

Approximate Dimensions in Inches (mm)

6

Admiral–SS
Front

6

Side One

Back

Side Two

6
6
6
6
6

50.54
(1283.8)

6
6
6
6
6
6
6
6
6

2.00
(50.8)

Water
Access

6
6
6

14.00
(355.6)

6
6

240V
Electrical
Access

CATV/INT.
Access

6
6

0.75
(19.1)

6

280V
Electrical
Access

10.00
(254.0)

CATV/INT.
Access

12.50 (317.5)

Ø 0.62
(Ø 15.9)

14.00 (355.6)

6

Base Footprint

6
6
V1-T6-64

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Power Pedestals
Marina Power and Lighting Equipment

6.5

Contents

Newport Harbor Mate

Description
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . .
Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Newport Harbor Mate
Available Options . . . . . . . . . . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .
Hatteras Light . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mariner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters . . . . . . . . .
Distribution Equipment—Ground Fault Monitor . .
Distribution Equipment—Mega Yacht Powerpoint
Distribution Equipment—Substations . . . . . . . . . .
Distribution Equipment—Panels . . . . . . . . . . . . . .
Distribution Equipment—Transformers . . . . . . . . .

Page
V1-T6-51
V1-T6-54
V1-T6-58
V1-T6-62
V1-T6-66
V1-T6-67
V1-T6-68
V1-T6-68
V1-T6-69
V1-T6-73
V1-T6-79
V1-T6-80
V1-T6-81
V1-T6-82
V1-T6-83
V1-T6-86
V1-T6-89
V1-T6-90

6
6
6
6
6
6
6
6
6
6
6
6
6
6

Newport Harbor Mate
Product Description
Five years of development
and 30 prototype models
have yielded this unit the
most innovative mini-power
center available. Host to a
variety of electrical services,
contained in a compact yet
strong housing, the Newport
Harbor Mate is packed with
features.

6

Features, Benefits
and Functions
●

●

●

●

6

Tough and durable resin
housing with UV inhibitor
for lasting finish
Photocell controlled 7 and
9 watt fluorescent light
(clear lens or amber lens
for bug reduction)
Designed to mount
on a dock box, piling or
stainless steel stand
Copper busbar with a
maximum rating of 140A

6
6
6
6
6
6
6
6
6
6
6
6
6
6

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-65

6.5
6
6
6
6
6

Power Pedestals
Marina Power and Lighting Equipment

Newport Harbor Mate (Shown with Optional Stand)

●

Tough and durable resin housing
with UV inhibitor for lasting finish

6

Photocell controlled 7 watt
fluorescent light with amber
lens for bug reduction

6
6
6

Available with single, dual
or combination of 30A or
50A receptacles
20A/125V GFI receptacle
(max. of two GFI
receptacles per pedestal)

Note: 20A GFI receptacles are
not to be used for shore power.
●

6

6

●

Available with single, dual or
combo of 30 or 50A receptacles
20A/125V GFI receptacle
Phone, cable TV, high-speed
Internet connections
Digital electronic meter
Lockable weatherproof door that
protects receptacles and breakers

6

Available Options

●

●
●

Single or dual phone, cable
TV, high-speed Internet
connections
Electronic metering
(one or two element
meters available)
316L stainless steel stand
LED lighting

Single or dual 1/2-turn brass ball
valve with 3/4-inch hose bibs
Stainless steel stand
Designed to mount on a dock
box, piling, wall or optional
stand (shown in photo)

6
6
6
6
6
6
6
6

Mounting Option

Backlit Faceplate

6
6
6
6
6
6
6
6
6
6
V1-T6-66

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Power Pedestals
Marina Power and Lighting Equipment

6.5

Catalog Number Selection

6

N A Y B U 4 3 0 1 1 2 W M
Type
N = NP Harbor Mate
C = NP Camp Mate
Lighting and Lens Color
A = 7W light
Amber
C = 9W light
Amber
F = No lighting
Amber
G = 7W light
Clear
I = 9W light
Clear
L = No lighting
Clear
M = 7W light
Special
O = 9W light
Special
R = No lighting
Special
S = 350 MA LED
Amber
T = 700 MA LED
Amber
U = 350 MA LED
Clear
V = 700 MA LED
Clear
W = 350 MA LED
Special
Y = 700 MA LED
Special

Photocell
Y = Yes
N = No
Lighting Protection
B = Breaker protected
F = Fuse protected
Metering Type 1
U = Unmetered
D = Digital electronic meters
R = Receptacles metered
individually

Sides and
Receptacles
R1S1 R2S1 R3S1
0
0
0
1
1
1
2
2
3
3
4
4
0 = None
1 = 20A GFI duplex
2 = 30A, 125V
3 = 50A, 125V
4 = 50A, 125/250V

Stand
0 =0
1 =1

6
Bus
S = Single-phase 1/4-inch copper busbar
F = Three-phase 1/4-inch copper busbar
C = Single-phase 1/4-inch Canadian busbar
M = Mechanical lug 2/0
Q = Single-phase 1/4-inch split mechanical
busbar (with stand ONLY)
A = 1/4-inch Canadian mechanical

Water
Option 2
0 =0
1 =1
2 =2

6
6
6
6
6
6
6

Hard Wired
Breakers
S1
0 = None
2 = 20A, two-pole
3 = 30A

6
6
6

Phone Cable TV and Internet Options
Phone Jack
Cable TV Jack
Internet Option
A =
1
0
0
B =
1
0
1
C =
1
0
2
D =
1
1
0
E =
1
1
1 (Camp Mate only)
T =
0
0
1
V =
0
1
0
W=
0
1
1
0 =
0
0
0

6
6
6
6

Receptacles: R1 = Receptacle 1
R2 = Receptacle 2

6

Notes
1 20A GFIs not metered.
2 Number represents the quantity of 1/4-turn ball valves with 3/4-inch hose bibs (with stand only).

6
6
6
6
6
6
6
6
6
6
6
6
6

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-67

6.5
6
6

Power Pedestals
Marina Power and Lighting Equipment

Accessories
See Page V1-T6-75.

Dimensions

6

Approximate Dimensions in Inches (mm)

6

Newport Harbor Mate

6

0.12
(3.2)

0.12
(3.2)

9.18 (233.0)

9.18 (233.0)

6
6

10.38
(263.7)

10.38
(263.7)

6
6
6

7.44
(189.1)

10.52 (267.2)

7.44
(189.1)

10.52 (267.2)

6
15.28
(388.0)

6
6

14.53
(369.0)

14.53
(369.0)

13.63
(346.2)

12.88
(327.2)

6
6
6

4º

4º

6

10.38 (263.7)

10.38 (263.7)

9.59 (243.6)

6
6
6
6
6

1.54
(39.1) 4.02
(102.2)

2.37
(60.3)
1.68
(42.7)

6

1.68
(42.7)

3.40
(86.4)
6.70
(170.2)
Newport Redesign

1.54
(39.1) 4.02
(102.2)

2.37
(60.3)
3.40
(86.4)
6.70
(170.2)

Newport Redesign With Meters

6
6
6
6
6
6
6
V1-T6-68

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Power Pedestals
Marina Power and Lighting Equipment

6.5

Contents

Hatteras Light

Description
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . .
Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . .
Hatteras Light
Available Options . . . . . . . . . . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mariner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters . . . . . . . . .
Distribution Equipment—Ground Fault Monitor . .
Distribution Equipment—Mega Yacht Powerpoint
Distribution Equipment—Substations . . . . . . . . . .
Distribution Equipment—Panels . . . . . . . . . . . . . .
Distribution Equipment—Transformers . . . . . . . . .

Page
V1-T6-51
V1-T6-54
V1-T6-58
V1-T6-62
V1-T6-65
V1-T6-70
V1-T6-71
V1-T6-72
V1-T6-72
V1-T6-73
V1-T6-79
V1-T6-80
V1-T6-81
V1-T6-82
V1-T6-83
V1-T6-86
V1-T6-89
V1-T6-90

6
6
6
6
6
6
6
6
6
6
6
6
6
6

Hatteras Light
Product Description
The Hatteras® Light is an
elegant and low cost
alternative to the Lighthouse.
It uses the same 360 degree
light assembly as the
Lighthouse, yet is only
30 inches tall. Thousands
of these attractive pedestals
are found not only in marinas,
but also around pools, deck
areas, boardwalks and
landscape areas. The housing
will never rust or corrode and
comes with a limited lifetime
warranty. This unit is popular
for smaller slips at marinas
with the Lighthouse and for
private docks.

6

Features, Benefits
and Functions
●

●
●

●

6

Photocell controlled
13 watt fluorescent light
(clear lens or amber lens
for bug reduction)
Circuit breakers
Heavy resin housing with
a two-part polyurethane
coating for a UV resistant,
long-lasting finish
Copper busbar with a
maximum rating of 140A

6
6
6
6
6
6
6

Note: Wireless remote reading
of electronic kilowatt meters.

6

Note: Clear lens.

6

Note: Custom paint color.

6
6
6
6
6
Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-69

6.5
6

Power Pedestals
Marina Power and Lighting Equipment

Available Options

Hatteras Light
360° controlled 13 watt
fluorescent light with amber
lens for bug reduction

6
6

Receptacle configurations
available:
Side 1: 30A, 50A
Side 2: 30A, N/A
Note: Custom configurations
also available

6
6

●

Note: 20A GFI receptacles are
not to be used for shore power.
●

●

Digital electronic metering

6
6

●

Circuit breakers

6

Phone, cable TV,
high-speed Internet
connections

6
6

20A/125V GFI receptacle
(max. of two GFI
receptacles per pedestal)

●

Digital electronic metering
(one or two element meter
available)
Single or dual phone, cable
TV, high-speed Internet
connections
Single or dual 1/2-inch or
3/4-inch silcock with
stainless steel handles
LED lighting

1/4-inch resin housing with a
two-part polyurethane coating
for a UV resistant, long-lasting
finish

6
6

1/2-turn brass ball valve and
3/4-inch hose bib

6
6
6
6
6
6
6
6

Copper Busbar with Ratings
up to 140A

20A/125A GFI Receptacle

6
6
6
6
6
6

Faceplate

6
6
6
6
V1-T6-70

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Power Pedestals
Marina Power and Lighting Equipment

6.5

Catalog Number Selection

6

H D Y B D 4 7 0 1 2 A M
Type
H = Hatteras Light
R = Park Light

A
B
C
D
E
F
G
H
I
J
K
L
M
N
O
P
Q
R
S
T
U
V
W
Y

Lighting and Lens Color
= 7W light
Amber
= Dual 7W light Amber
= 9W light
Amber
= 13W light
Amber
= Dual 13W light Amber
= No lighting
Amber
= 7W light
Clear
= Dual 7W light Clear
= 9W light
Clear
= 13W light
Clear
= Dual 13W light Clear
= No lighting
Clear
= 7W light
Special
= Dual 7W light Special
= 9W light
Special
= 13W light
Special
= Dual 13W light Special
= No lighting
Special
= 350 MA LED
Amber
= 700 MA LED
Amber
= 350 MA LED
Clear
= 700 MA LED
Clear
= 350 MA LED
Special
= 700 MA LED
Special

6
Bus
S = Single-phase 1/4-inch copper busbar
F = Three-phase 1/4-inch copper busbar
C = Single-phase 1/4-inch Canadian busbar
M = Mechanical lug 2/0 3
A = 1/4-inch Canadian mechanical

Photocell
Y = Yes
N = No
Lighting Protection
B = Breaker protected
F = Fuse protected
Metering Type 1
U = Unmetered
D = Digital electronic meters
R = Receptacles metered
individually

Sides and
Receptacles
R1S1 R2S1 R1S2
0
0
0
1
1
1
2
2
2
3
3
3
4
4
4
0 = None
1 = 20A GFI duplex
2 = 30A, 125V
3 = 50A, 125V
4 = 50A, 125/250V

Water Option 2
0 =0
1 = 1 (1/2-inch)
2 = 2 (1/2-inch)
3 = 1 (3/4-inch)
4 = 2 (3/4-inch)
Hard Wired
Breakers
S1
0 = None
2 = 20A, two-pole
3 = 30A

6
6
6
6

Phone Cable TV and Internet Options
Phone
Cable TV
Internet
Jack
Jack
Option
A= 1
0
0
B= 1
0
1
C = 1
0
2
D= 1
1
0
E = 1
1
1
F = 1
1
2
G= 1
2
0
H= 1
2
1
I = 1
2
2
J = 2
0
0
M= 2
1
0
P = 2
2
0
S = 0
2
2
T = 0
0
1
U= 0
0
2
V = 0
1
0
W= 0
1
1
X = 0
1
2
Y = 0
2
0
Z = 0
2
1

6
6
6
6
6
6
6
6
6

Receptacles: R1 = Receptacle 1
R2 = Receptacle 2

6

Notes
1 20A GFIs not metered.
2 Number represents the quantity of 1/4-turn ball valves with 3/4-inch hose bibs.
3 Wire size #2/0 kcmil or less.

6
6
6
6
6
6
6
6
6
6
6
6
6
6

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-71

6.5
6
6

Power Pedestals
Marina Power and Lighting Equipment

Accessories
See Page V1-T6-75.

Dimensions

6

Approximate Dimensions in Inches (mm)

6

Hatteras

6
6
6
6
6
6

Busbar Access Top Removed

6

Inside Top

6

13.39
(340.2)

6
6
6
6
6
6
6
6

30.98
(786.9)

6
6
6
6
6
6
6
6
6
6
V1-T6-72

7.90 (200.7)

7.90 (200.7)

Side View

Front View

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Power Pedestals
Marina Power and Lighting Equipment

6.5

Contents

Firehouse

Description

Page

Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . .
Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . .
Hatteras Light . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Firehouse
Available Options . . . . . . . . . . . . . . . . . . . . . . .
Catalog Number Selection . . . . . . . . . . . . . . . .
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mariner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters . . . . . . . . .
Distribution Equipment—Ground Fault Monitor . .
Distribution Equipment—Mega Yacht Powerpoint
Distribution Equipment—Substations . . . . . . . . . .
Distribution Equipment—Panels . . . . . . . . . . . . . .
Distribution Equipment—Transformers . . . . . . . . .

V1-T6-51
V1-T6-54
V1-T6-58
V1-T6-62
V1-T6-65
V1-T6-69
V1-T6-74
V1-T6-74
V1-T6-75
V1-T6-78
V1-T6-79
V1-T6-80
V1-T6-81
V1-T6-82
V1-T6-83
V1-T6-86
V1-T6-89
V1-T6-90

6
6
6
6
6
6
6
6
6
6
6
6
6
6

Firehouse
Product Description
Created as a complete
solution for fire and rescue
needs, this pedestal features
fire extinguisher storage and
a mounted alarm strobe light
and siren, as well as an
optional life ring. This unit
is well equipped for any
marina emergency. The alarm
strobe light and siren can be
automatically activated when
the door is open or optional
life ring is removed.

Features, Benefits
and Functions
●

●

●

●

●

6

Firehouse

Alarm strobe light and
siren: automatically
activated when door is
open or optional life ring
is removed
Photocell controlled
13 watt fluorescent light
(clear lens or amber lens
for bug reduction)
10 lb ABC Type fire
extinguisher
316L stainless steel
polyester powder-coated
housing
Polycarbonate top
assembly

6

High-visibility alarm
strobe light and warning
siren

6

Photocell controlled
energy efficient 13 watt
fluorescent light with
amber lens for bug
reduction

6
6

Stainless steel housing with
oven-baked enamel finish
with a polycarbonate base
and top

6

Remote control unit can
automatically call select
services via a four
channel transmitter:
Medical emergency
Fire emergency
Police emergency
Optional general
emergency

6

6
6
6
6
6
6
6
6
6

Volume 1—Residential and Light Commercial

CA08100002E—February 2014

www.eaton.com

V1-T6-73

6.5
6
6
6

Power Pedestals
Marina Power and Lighting Equipment

Available Options
●
●

24-inch life ring
20 lb ABC Type fire
extinguisher available

Catalog Number Selection

6

F A Y A E N

6

24-Inch Life Ring
R = Include life ring
N = No life ring

Type
F = Firehouse

6

Photocell
Y = Yes
N = No

6

Alarm/Strobe
A = Include alarm/strobe
N = No alarm/strobe

6
6

A
B
C
D
E
F
G
H

6
6
6

= 7W light
= Dual 7W light
= 9W light
= 13W light
= Dual 13W light
= No lighting
= 7W light
= Dual 7W light

Amber
Amber
Amber
Amber
Amber
Amber
Clear
Clear

Fire Extinguisher
E = Include 10 lb extinguisher
N = No extinguisher
X = Include 20 lb extinguisher

Lighting and Lens Color
I = 9W light
Clear
J = 13W light
Clear
K = Dual 13W light Clear
L = No lighting
Clear
M = 7W light
Special
N = Dual 7W light Special
O = 9W light
Special
P = 13W light
Special

Q = Dual 13W light
R = No lighting
S = 350 MA LED
T = 700 MA LED
U = 350 MA LED
V = 700 MA LED
W = 350 MA LED
Y = 700 MA LED

6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
V1-T6-74

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Special
Special
Amber
Amber
Clear
Clear
Special
Special

6.5

Power Pedestals
Marina Power and Lighting Equipment

Accessories

6

Accessories for Custom Design Marina Products, Resin and Stainless Steel Pedestals and Power Products
Replacement Parts Catalog Numbers
Catalog
Number

Description

6

Replacement Parts Catalog Numbers, continued

Receptacles
20A GFCI duplex

MPL3038

30A 125V twistlock

MPL3039

50A 125V twistlock

MPL3040

50A 125/250V twistlock

MPL3045

100A 120/240V pin and sleeve

MPL4100R12W

100A 120/208V pin and sleeve

MPL5100R9W

100A 480V four-wire pin and sleeve

MPL4100R7W

Description

6

Lighthouse, Lighthouse–SS, Powerhouse,
Powerhouse–SS, Hatteras, Park Light, continued
20A GFCI receptacle external cover set

MPL1101

30A receptacle external cover set

MPL1102

50A receptacle external cover set

MPL1105

Single-pole external breaker cover set

MPL11061

Two-pole external breaker cover set

MPL11062

Three-pole external breaker cover set

MPL11063

100 A 480V five-wire pin and sleeve

MPL5100R7W

Lighthouse, Lighthouse–SS, Powerhouse,
Powerhouse–SS

200A 277/480V pin and sleeve (Russellstoll®)

MPL4200R7W

Lighthouse/Powerhouse pedestal main housing

MPL6006

30A 125V RV

RV3042

Lighthouse–SS/Powerhouse–SS pedestal main housing

MPL6006S

50A 125/250V RV

RV3043

Lighthouse/Powerhouse main door

MPL6007

Circuit Breakers

6

Catalog
Number

6
6
6
6
6
6
6

Lighthouse–SS/Powerhouse–SS main door

MPL6007S

20A 125V single-pole

QCF1020

Lighthouse/Powerhouse spring closure

MPL1099

20A 125V single-pole GFCI

QCGF1020

Lighthouse Powerhouse top isolation plate

MPL6012

30A 125V single-pole

QCF1030

Lighthouse/Lighthouse–SS breaker plate

MPL1141

30A 125V single-pole GFCI

QCGF1030

Powerhouse/Powerhouse–SS breaker plate

RV1112

50A 125V single-pole

QCF1050
QCF2020

Lighthouse/Lighthouse–SS/Powerhouse/
Powerhouse–SS Hose and cable brackets

MPL1087

20A 125/250V two-pole

6

20A 125/250V two-pole GFCI

QCGF2020

Lighthouse/Powerhouse stainless steel hinge

MPL1088

6

30A 125/250V two-pole

QCF2030

Lighthouse/Powerhouse complete pedestal
base with busbar assembly

MPL6004A

30A 125/250V two-pole GFCI

QCGF2030

MPL6004FA

50A 125/250V two-pole

QCF2050

Lighthouse/Powerhouse complete pedestal base with three-phase
busbar assembly

50A 125/250V two-pole GFCI

QCGF2050

Lighthouse/Powerhouse pedestal base without busbars

MPL6004

60A 125/250V two-pole

QCF2060

Lighthouse/Powerhouse aluminum blank access panel

MPL5500

100A 125/250V two-pole

GHC2100D

MPL1140A

100A 120/208V three-pole

GHC3100D

Lighthouse/Lighthouse–SS/Powerhouse/
Powerhouse–SS complete busbar assembly

6

Lighthouse/Lighthouse–SS/Powerhouse/Powerhouse–SS complete
three-phase busbar assembly

MPL1140FA

Copper busbar with nuts and washers

MPL3471

6

20A GFCI—00 amber resin faceplate

MPL1120

30A—20 GFCI amber resin faceplate

MPL1121

30–50A amber resin faceplate

MPL1122

30–30A amber resin faceplate

MPL1127

30–00A amber resin faceplate

MPL1129

50–50A amber resin faceplate

MPL1123

50A—20 GFCI amber resin faceplate

MPL1124

20 GFCI—20 GFCI amber resin faceplate

MPL1125

00–00 amber resin faceplate

MPL1126

50A—00 amber resin faceplate

MPL1128

100A faceplate

MPL1142

200A 277/480V three-pole

JT2200FA

Fluorescent Light Assembly
13 watt 120V 60 Hz ballast

MPL2400

7 watt 120V 60 Hz ballast

MPL2401

13 watt socket

MPL3079

7 watt socket

MPL3077

13 watt fluorescent bulb

MPL3018

7 watt fluorescent bulb

MPL3019

Photocell

MPL3044

Photocell nuts

MPL3034

Lighthouse in-line fuse

MPL3026

Lighthouse in-line fuse holder

MPL3027

Lighthouse, Lighthouse–SS, Powerhouse,
Powerhouse–SS, Hatteras, Park Light
Top with complete light and lens assembly

MPL6003A

20A GFCI—00 amber resin faceplate assembly with breakers

MPL1120A

Top with complete light and lens assembly—fused

MPL6003FA

30A—20 GFCI amber resin faceplate assembly with breakers

MPL1121A

Top only

MPL6003

30–50A amber resin faceplate assembly with breakers

MPL1122A

Amber lens

MPL6005

Clear lens

MPL6008

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

6
6

6
6
6

6
6
6
6
6
6
6
6
6
6
V1-T6-75

6.5

Power Pedestals
Marina Power and Lighting Equipment

6

Replacement Parts Catalog Numbers, continued

6

Description

6

Catalog
Number

Lighthouse, Lighthouse–SS, Powerhouse,
Powerhouse–SS, continued
MPL1127A

50–50A amber resin faceplate assembly with breakers

MPL1123A

50A—20 GFCI amber resin faceplate assembly with breakers

MPL1124A

20 GFCI—20 GFCI amber resin faceplate assembly with breakers

MPL1125A

50A—00 amber resin faceplate assembly with breakers

MPL1128A

30–00A faceplate assembly with breakers

MPL1129A

6

100A faceplate assembly with breakers

MPL1142A

Powerhouse 30–50 receptacle plate

RV1143

6

Powerhouse (30A—00) receptacle plate

RV11433

Powerhouse (50A—00) receptacle plate

RV11435

6

Powerhouse breaker plate

RV1112

6
6

Description

Catalog
Number

Digital Electronic Meters

30–30A amber resin faceplate assembly with breakers

6

Replacement Parts Catalog Numbers, continued

Single element, 14-pin quick disconnect (no CTs)

MPL17A1

Single element, 14-pin quick disconnect (with CTs)

MPL17A2 1

Single element, 14-pin quick disconnect (with CTs)

MPL17A2 2

Dual element, 14-pin quick disconnect (no CTs)

MPL17B1

Dual element, 14-pin quick disconnect (with CTs)

MPL17B2 1

Dual element, 14-pin quick disconnect (with CTs)

MPL17B2 2

Three element, 14-pin quick disconnect (no CTs)

MPL17C1

Three element, 14-pin quick disconnect (with CTs)

MPL17C2 1

Three element, 14-pin quick disconnect (with CTs)

MPL17C2 2

Single element coil transformers (CTs)

MPL30321 1

Single element coil transformers (CTs)

MPL30321 2

Dual element coil transformers (CTs)

MPL30322 1

Dual element coil transformers (CTs)

MPL30322 2

Three element coil transformers (CTs)

MPL30323 1

Three element coil transformers (CTs)

MPL30323 2

6

Phone, Cable, Internet Assemblies
Lighthouse/Powerhouse complete phone and cable assembly

MPL1114/RV1114

6

Lighthouse–SS/Powerhouse–SS/Hatteras Light/Park Light complete
phone and cable assembly

MPL1119/RV1119

6

Hatteras Light/Park Light complete phone and cable assembly

MPL1119

Counter (large—old style)

MPL3022

Newport Harbor Mate/Camp Mate phone and cable insert assembly

MPL1115/RV1115

Counter (small—new style)

MPL3021

Lighthouse/Powerhouse access plates with dual Internet jacks

MPL5501

Hatteras Light (Marina) and Park Light (RV) 3

Coax cable TV FCF female adpt. with lugnut and washer

MPL1086

Pedestal main housing

MPL6002

MPL3059

Copper busbar with nuts and washers

MPL3468

MPL3037

Complete busbar assembly

MPL1108A

RV3060

Complete three-phase busbar assembly

MPL1108FA

20A GFCI external cover door

MPL1101

30A external cover door

MPL1102

50A external cover door

MPL1105

Light fuse

MPL3026

Fuse holder

MPL3027

Mounting feet (set of four)

MPL7004

6
6

RJ45 CAT5e high-speed internet jack

6

Marine phone receptacle

6

Water Assemblies

6
6

RJ12 CAT3 phone jack

Lighthouse/Powerhouse complete water manifold assembly
(dual 3/4-inch hose bibs with 1/4-turn ball valves)

MPL11A

Newport Harbor Mate/Newport Camp Mate water manifold
assembly (dual 3/4-inch hose bibs with 1/4-turn ball valves)

MPL11C

3/4-inch hose adapter

MPL7030

6

Lighthouse/Powerhouse water mounting plate
with mounting brackets

MPL1132

6

Hatteras Light/Park Light aluminum water mounting plate

MPL6584

1/2-inch brass silcock (hose bib)

MPL7014

6

3/4-inch stainless steel silcock (hose bib)

MPL5271

6

3/4-inch brass ball valve

MPL7021

Watts 3/4-inch backflow preventer

MPL7015

Notes
1 Lighthouse, Lighthouse–SS, Powerhouse, Powerhouse–SS.
2 Hatteras Light, Park Light, Newport Camp Mate, Newport Harbor Mate.
3 Please contact factory to determine configurations for replacement housing.

6
6
6
6
6
6
6
6
V1-T6-76

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Power Pedestals
Marina Power and Lighting Equipment

6.5

Replacement Parts Catalog Numbers, continued
Description

6

Catalog
Number

6

Newport Harbor Mate (MARINA)
and Camp Mate (RV)
Amber lens—three-piece

MPL1117

Clear lens—three-piece

MPL1109

Main housing

MPL6000

Main door

MPL6001

30–30A faceplate 1

MPL1135

30–50A faceplate 1

MPL1136

50–50A faceplate 1

MPL1137

50A–00 faceplate 1

MPL1138

30A–00 faceplate 1

MPL1139

30–30A faceplate assembly with breakers 1

MPL1135A

30–30–20 GFI faceplate assembly 1

MPL1135G/RV1135G

30–50A faceplate assembly with breakers 1

MPL1136A

30–50–20 GFI faceplate assembly 1

MPL1136G/RV1136G

50–50A faceplate assembly with breakers 1

MPL1137A

50–50–20 GFI faceplate assembly 1

MPL1137G/RV1137G

50A–00 faceplate assembly with breakers 1

MPL1138A

50–20 GFI faceplate assembly 1

MPL1138G/RV1138G

30A–00 faceplate assembly with breakers 1

MPL1139A

30–20 GFI faceplate assembly 1

MPL1139G/RV1139G

Mounting brackets

MPL7005

36-inch stainless steel stand

MPL5506

Copper busbar with nuts and washers

MPL3468

Complete busbar assembly

MPL1108A

Complete three-phase busbar assembly

MPL1108FA

6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Firehouse (Marina and RV)
Red strobe light/siren

MPL3020

Firehouse top with lighting assembly and strobe

MPLFH6003A

Light fuse

MPL3029

Fuse holder

MPL3028

Door

MPL6013

24-inch life ring

MPL4201

Life ring bracket

MPL4201B

Blank access panel

MPL6015

Door/life ring switch (pre-2004)

MPL3030

Door/life ring switch (new)

MPL3050

Door hasp

MPL3950

Busbar (double barrel terminal block)

MPL3751

10-lb ABC Type fire extinguisher

MPL8025

20-lb ABC Type fire extinguisher

MPL8025X

6
6
6
6
6
6
6
6
6

Note
1 For custom faceplates to include phone/cable or other accessories,
please contact Eaton’s Marina Power & Lighting facility at 1-800-723-8009.

6
6
6
6

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-77

6.5
6
6
6

Power Pedestals
Marina Power and Lighting Equipment

Dimensions
Approximate Dimensions in Inches (mm)
Firehouse–SS

6
6
6
6
6
6
6
6
6
6

43.50
(1104.9)

6
6
6
6
6
6
6
6
6
6
6
9.87
(250.6)

6
6
6
6
6
6
V1-T6-78

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

6.5

Power Pedestals
Marina Power and Lighting Equipment

Contents

Smart Start

Description

Page

Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . .
Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . .
Hatteras Light . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Smart Start
Mariner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters . . . . . . . . .
Distribution Equipment—Ground Fault Monitor . .
Distribution Equipment—Mega Yacht Powerpoint
Distribution Equipment—Substations . . . . . . . . . .
Distribution Equipment—Panels . . . . . . . . . . . . . .
Distribution Equipment—Transformers . . . . . . . . .

V1-T6-51
V1-T6-54
V1-T6-58
V1-T6-62
V1-T6-65
V1-T6-69
V1-T6-73
V1-T6-80
V1-T6-81
V1-T6-82
V1-T6-83
V1-T6-86
V1-T6-89
V1-T6-90

6
6
6
6
6
6
6
6
6
6
6
6
6
6

Smart Start
Product Description

Features

If you have transient boat
slips, Eaton Marina Power
and Lighting has developed
their newest product for
your situation.

●

The new “Smart Start”
pedestal is activated by the
swipe of a credit card. A kiosk
will be centrally located at the
marina and will control up to
32 power pedestals. When a
boater wants to use a slip,
they will enter the slip
number and amount of time
they would like and will then
be asked to swipe a card in
order to activate the pedestal.
Once the chosen time is up,
the pedestal will shut down.
No more free power!

●

●

Lighted 316L stainless
steel kiosk enclosure
Programmable slip
time blocks
Programmable slip rates
printable receipts

Standards and Certifications
●

UL listing pending

Dimensions
Approximate Dimensions in
Inches (mm)
Smart Start
Height

60.05 (1525.3)

Width

14.15 (359.4)

Depth

14.24 (361.9)

6
6
6
6
6
6
6
6
6
6

The “Smart Start” pedestal
will not only prevent transient
boaters from stealing power,
but it will also eliminate the
need for 24-hour monitoring
of the slips. Boaters will be
able to come in at any time
of the day and activate a
pedestal.

6
6
6
6
6
6
Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-79

6.5
6

Power Pedestals
Marina Power and Lighting Equipment

Contents

Marina Power and Lighting Equipment

Description

6
6
6
6
6
6
6
6

Page

Power Pedestals. . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . .
Hatteras Light. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mariner
Digital Electronic Kilowatthour Meters . . . . . . . . . .
Distribution Equipment—Ground Fault Monitor. . .
Distribution Equipment—Mega Yacht Powerpoint .
Distribution Equipment—Substations . . . . . . . . . .
Distribution Equipment—Panels . . . . . . . . . . . . . .
Distribution Equipment—Transformers . . . . . . . . .

Mariner

6
6
6
6
6

Mariner

6

Product Description

Features

The Mariner is a lighting
bollard that can stand from
1.5 to 4 feet tall and can be
used in various applications
from marina docks, to
landscaped areas, golf
courses and beyond. The
Mariner will have a lifetime
warranty on the engineered
resin housing that will
withstand the harsh marine
and land environments from
Alaska to the tropics.

●

6
6
6
6
6
6
6

●

●

●
●

Dimensions

Can be configured with a
7 watt, 9 watt or 13 watt
fluorescent bulb
Mounting base and painted
pole supplied for desired
height
Limited lifetime warranty
on engineered resin
housing
Custom colors available
Side-mounted option

Approximate Dimensions in
Inches (mm)
Mariner
7 watt

14.15 (359.4)

9 watt/13 watt 14.24 (361.9)

Mounting Base and Pole
1.5 feet–4 feet

Catalog Number Selection

M 5 A R 18

6
6

Type
M = Mariner

6
6

Bulb Wattage
5 = 5W
7 = 7W
9 = 9W
3 = 13W
1 = 50 MA LED

Color Lens
A = Amber
C = Clear
S = Special

Color
W = White
R = Blue
B = Black
D = Dark green
S = Special

Stand Height
18 = 18-inch
24 = 24-inch
36 = 36-inch
48 = 48-inch

6
6
6
6
V1-T6-80

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-51
V1-T6-54
V1-T6-58
V1-T6-62
V1-T6-65
V1-T6-69
V1-T6-73
V1-T6-79
V1-T6-81
V1-T6-82
V1-T6-83
V1-T6-86
V1-T6-89
V1-T6-90

6.5

Power Pedestals
Marina Power and Lighting Equipment

Contents

Digital Electronic Kilowatt Hour Meters

Description

Page

Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . .
Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . .
Hatteras Light . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mariner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters
Distribution Equipment—Ground Fault Monitor . .
Distribution Equipment—Mega Yacht Powerpoint
Distribution Equipment—Substations . . . . . . . . . .
Distribution Equipment—Panels . . . . . . . . . . . . . .
Distribution Equipment—Transformers . . . . . . . . .

V1-T6-51
V1-T6-54
V1-T6-58
V1-T6-62
V1-T6-65
V1-T6-69
V1-T6-73
V1-T6-79
V1-T6-80
V1-T6-82
V1-T6-83
V1-T6-86
V1-T6-89
V1-T6-90

6
6
6
6
6
6
6
6
6
6
6
6
6
6

Digital Electronic Kilowatthour Meters
Product Description

Features

Available Options

Using the latest surface
mount technology, Eaton
manufactures a digital
electronic kilowatthour meter
that exceeds the +/– 2%
accuracy required by ANSI
(American National Standards
Institute) C-12.1 and is
approved by the state of
California at +/– 1% over the
full range of 0–100A from a
0.5–1 power factor and is
available for both single- and
three-phase applications.

Our meter is designed to
be user friendly in that all
connections from external
sources and the meter output
are through one 14-pin locking
connector. This feature
eliminates many common
problems, such as reverse
line polarity and improper coil
polarity. Simple LEDs, both
red and green, indicate line
and load condition and the
pulsed LED indicates the rate
of power consumption.

●

The meter drives an electromechanical counter that
requires a 12V pulse each
tenth of a kilowatthour,
providing 10 pulses per
kilowatt used. The meter
output can be hard wired or
connected to a transmitter
in the pedestal for wireless
transmission to a receiver
displaying the output on a
PC for direct billing of up to
1,000 individual customers.

Wireless System
All of our meters are “wireless
capable” to allow for wireless
meter reading. This technology
enables the marina or RV park
to get meter readings from
one central location rather
than visiting every site to
read the counters.

●
●
●
●

6

Product Selection

200A (SS only)
Lockable hasp
Ringless (SS only)
Five jaw
Seven jaw (SS only)

6
6
6
One Element Meter

6
6
6
6

Two Element Meter

6
6
6

Meter Socket Capabilities
Meter sockets are available
on the Lighthouse and
Lighthouse–SS.
Standard
●
Four jaw
●
Ring-type
●
100A

6

6
6
Three Element Meter

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

6
6

V1-T6-81

6.5
6

Power Pedestals
Marina Power and Lighting Equipment

Contents

Ground Fault Monitor

Description

6

Power Pedestals. . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . .
Hatteras Light. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mariner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters . . . . . . . . . .
Distribution Equipment—Ground Fault Monitor
Distribution Equipment—Mega Yacht Powerpoint .
Distribution Equipment—Substations . . . . . . . . . .
Distribution Equipment—Panels . . . . . . . . . . . . . .
Distribution Equipment—Transformers . . . . . . . . .

6
6
6
6
6
6
6
6
6
6
6
6

Distribution Equipment—Ground Fault Monitor

6

Product Description

Features

Our ground fault monitoring
systems are designed to
detect fault currents in the
AC shore power system that
are too low to trip a circuit
breaker. The ground fault
monitor helps reduce the risk
of injury or property damage
that may result from stray
fault currents. Our ground
fault monitoring system
provides information to the
maintenance staff on the
overall condition of the AC
electrical system. The ground
fault monitoring system
operates 24 hours a day and
can be monitored by nontechnical personnel.

●

6
6
6
6
6
6
6
6
6
6
6
6

●

●
●

Adjustable trip level 10 mA
to 10A
Current transformers up to
8 1/4-inch diameter
Visual and/or audible alarm
Housing of fiberglass or
powder-coated stainless
steel available

Standards and Certifications
●

UL listed current
transformers

Power Guard
The ground fault monitor
detects ground fault currents
by means of current
transformers (CT), which are
placed around main or branch
circuits. If a ground fault
occurs, the CT will detect the
amount of fault current and
send a signal to the ground
fault monitoring device where
the amount of fault current is
displayed with the faulty
circuit identified. The
detected fault can either
activate an indicator alarm or
disconnect the faulted circuit.

6
6
6
V1-T6-82

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Page
V1-T6-51
V1-T6-54
V1-T6-58
V1-T6-62
V1-T6-65
V1-T6-69
V1-T6-73
V1-T6-79
V1-T6-80
V1-T6-81
V1-T6-83
V1-T6-86
V1-T6-89
V1-T6-90

Power Pedestals
Marina Power and Lighting Equipment

6.5

Contents

Marina Power and Lighting Equipment

Description

Page

Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . .
Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . .
Hatteras Light . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mariner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters . . . . . . . . .
Distribution Equipment—Ground Fault Monitor . .
Distribution Equipment—Mega Yacht Powerpoint
Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .
Distribution Equipment—Substations . . . . . . . . . .
Distribution Equipment—Panels . . . . . . . . . . . . . .
Distribution Equipment—Transformers . . . . . . . . .

V1-T6-51
V1-T6-54
V1-T6-58
V1-T6-62
V1-T6-65
V1-T6-69
V1-T6-73
V1-T6-79
V1-T6-80
V1-T6-81
V1-T6-82
V1-T6-84
V1-T6-85
V1-T6-86
V1-T6-89
V1-T6-90

6
6
6
6
6
6
6
6
6
6
6
6
6
6

Distribution Equipment—Mega Yacht Powerpoint
Product Description

Features

From the company that is
known for its high-quality
innovations, Eaton is the only
company to offer a selfcontained dual-phase mega
yacht unit. Made out of longlasting stainless steel, this
mega yacht unit has a
copper-wound, low-noise
transformer that is double
insulated and epoxy
overcoated.The mega yacht
unit delivers both singlephase and three-phase power
to serve most mega yachts.
Helping to keep your marina
environment tranquil, the
mega yacht unit has a
low-noise, highly efficient
transformer that has isolation
mounts to ensure a very
quiet operation.

●

●

●

●

●

Thermostatically controlled
fans in transformer
compartment for cooling
Heavy stainless steel
(316L) cabinet with a
polyester powder coating
Ventilated sun shields to
help unit run cooler in
tropical climates
Limited lifetime warranty
on housing
Two or three light 13 watt
photocell controlled
fluorescent lights on
the sun shield for optimal
night lighting

Available Options
●

●
●

●

●

●

●
●

●

●

200A–480V three-phase
receptacles
100% rated breakers
Hard wiring busbars for
all voltages with breaker
protection
Two 3/4 inch water outlets
with a water meter
Two phone, two CATV
and two CAT5 high-speed
Internet connections
Digital electronic meters
on all receptacles
Primary breaker
Two 480V delta or wye
125A three-phase
receptacles (IEC)
Two 120/208V 100A threephase receptacles (IEC)
Two 120/240V 100A singlephase receptacles (IEC)

●

●

●

●
●

●

●

●

Up to four 50A 120/240V
locking receptacles
(NEMA)
Up to four 30A 120V
locking receptacles
(NEMA)
Wireless remote metering
for electric and water
20A GFI receptacle
Primary side 480V
maximum 600A
Secondary side singlephase 120/240V maximum
100 kVA
Secondary side threephase 120/208V maximum
125 kVA
Fire extinguisher—10 or
20 lbs

6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-83

6.5

Power Pedestals
Marina Power and Lighting Equipment

6

Wiring Diagram

6

Powerpoint

6

120/240V Single-Phase Supply

120/240V Three-Phase Supply
1

6

277/480V Supply
from Utility

480V
3Ø 3-Pole
Main
Breaker
Dual-Phase Primary
Transformer 480V

6

A

6

A

6

O

B

A

6
6

N
B

120/240V
100A 1Ø
2-Pole
Breaker

120/240V
100A 1Ø
2-Pole
Breaker

N

N

2

3

B

To 480V
Service

1 2 3

1 2 3

1 2 3

3 Ø, 277/480V
Supply from
Main Breaker

3 Ø, 277/480V
Supply from
Main Breaker

3 Ø, 277/480V
Supply from
Main Breaker

120/208V
100A 3Ø
3-Pole
Breaker

120/208V
100A 3Ø
3-Pole
Breaker

120/208V
100A 3Ø
3-Pole
Breaker

480V
100A 3Ø
3-Pole
Breaker

480V
100A 3Ø
3-Pole
Breaker

480V
100A 3Ø
3-Pole
Breaker

N

N

CT for
Electronic
Meter (Typ.)

N

N

N

G

6
6

G

G

G

G

100A Hard
Wire Buss
120/480V

G

G

6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
V1-T6-84

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

200A Hard Wire Buss
277/480V
(Ground & Neutral
from Utility Supply)

Power Pedestals
Marina Power and Lighting Equipment

6.5

Dimensions

6

Approximate Dimensions in Inches (mm)

6

Powerpoint Unit

6
6
6
6
6
6

Top With Solar Shield

6

31.00
(787.4)

46.00 (1168.4)

6
6
6
48.54
(1232.9)

6
6
6
6

Left Side

Right Side

Front

6
6

26.00
(660.4)

6
6

26.00
(660.4)

6
6

Ø 0.50
(Ø 12.7)

6

Base

6
6
6
6
6
6
6

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-85

6.5
6

Power Pedestals
Marina Power and Lighting Equipment

Contents

Substations

Description

6
6
6
6
6
6
6
6

Double Panel Substation

6
6
6

Page

Power Pedestals. . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . .
Hatteras Light. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mariner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters . . . . . . . . . .
Distribution Equipment—Ground Fault Monitor. . .
Distribution Equipment—Mega Yacht Powerpoint .
Distribution Equipment—Substations
Features, Benefits and Functions . . . . . . . . . . .
Available Options. . . . . . . . . . . . . . . . . . . . . . . .
Standards and Certifications . . . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Distribution Equipment—Panels . . . . . . . . . . . . . .
Distribution Equipment—Transformers . . . . . . . . .

6
6

Distribution Equipment—Substations

6

Product Description

Application Description

The introduction of
substations into the marina
and recreational vehicle
market allows Eaton to be
your complete marina and RV
park electrical products
supplier. We are able to
assist in the design and
layout of your marina or RV
park electrical system from
the primary service provider,
to your power pedestal.
Our substations are designed
for any coastal or inland
environment and are
constructed of powdercoated stainless steel NEMA
3R housing cabinets. All
substation cabinets come
with our limited lifetime
warranty. All of our
substations use Eaton’s
panels and circuit breakers
providing our customers the
utmost in circuit protection
and quality.

The aluminum and Galvaneal
cabinets are recommended
for inland applications.
The substations can be
configured with 50–330 kVA
single-phase or three-phase
copper wound transformers
and up to 20 single-phase or
12 three-phase branch
breakers. An optional threesided double-wall cabinet is
available that provides air
flow between the panels. All
substations come standard
with temperature controlled
cooling fans.

6
6
6
6
6
6
6
6
6
6
6

Product Selection Guide
Panel and Transformer
Combinations
Panel

Transformer

Single-Phase
200A

50 kVA

300A

75 kVA

400A

100 kVA

600A

150 kVA

700A

167.5 kVA

800A

200 kVA

1000A

250 kVA

1200A

330 kVA

Three-Phase
100A

45 kVA

200A

75 kVA

300A

112.5 kVA

400A

150 kVA

600A

225 kVA

800A

300 kVA

6
6
6
6
V1-T6-86

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-51
V1-T6-54
V1-T6-58
V1-T6-62
V1-T6-65
V1-T6-69
V1-T6-73
V1-T6-79
V1-T6-80
V1-T6-81
V1-T6-82
V1-T6-83
V1-T6-87
V1-T6-88
V1-T6-88
V1-T6-88
V1-T6-89
V1-T6-90

Power Pedestals
Marina Power and Lighting Equipment

6.5

Features, Benefits
and Functions
●

●

●

●

Limited lifetime warranty
on the housing
All stainless steel
hardware
Temperature controlled
cooling fans in the
transformer and circuit
breaker compartments
Lockable door

Ventilation
The substation ventilation
is designed to optimize air
circulation over and around
the transformers and through
the panel compartment so
that the substation operates
at lower temperatures.
Substations come equipped
with temperature controlled
cooling fans for exhausting
hot air from the cabinet and
solar shield.

6
6

Substations
Temperature-controlled
fans for cooling

Stainless steel housing
with polyester
powder coating

6
6
6
6
6
6

Limited
lifetime
warranty
on the
housing

6
6

Stainless steel hardware
with locking doors

6
6
6

In addition, substations are
available with a doublewalled cabinet and solar
shield, which allow for
cooling of both the exterior
surface of the cabinet and
the internal components.

6
6
6
6
6
Custom made to your specifications:
Single-phase or three-phase copper
wound transformers
50 to 330 kVA

6

Up to 1200A main circuit breaker with
20 single-phase or 12 three-phase
branch circuit breakers

6
6

Sun Heat

6
6
6

Air
Transformers

Double-Walled
Stainless

6
6
6
6

Cool Air

6

Double-Walled Construction

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

6
V1-T6-87

6.5
6

●

●

6
6

●

6
6
6

●

●

6

●

6

●

6

●

6
6

●

6
6
6
6
6

Marina Power and Lighting Equipment

Available Options

6
6

Power Pedestals

●

●

Powder-coated cabinets
made of stainless steel
or fiberglass
Limited lifetime warranty
on housing. Transformer
and secondary distribution
panel in a single enclosure
have a one-year limited
warranty
Stainless steel housing
and hardware with
locking doors
Single-phase and threephase models
Overload capacity meets
ANSI L57.96–01.250
Optional double-walled
construction
Temperature controlled
fans for cooling
Custom-made copper
wound single-phase or
three-phase transformers
from 50–330 kVA
Up to 1200A main circuit
breaker with 15 singlephase branch circuit
breakers or 10 three-phase
branch circuit breakers
Substations can be
equipped with photocells
to turn on and off lights
A 20A GFI can be installed
in the cabinet, as well as
a ground fault monitoring
system

Standards and Certifications
●

cULus listed

Dimensions
Approximate Dimensions in
Inches (mm)
Substations
Standard Substation
Height

53.00 (1346.2)

Width

51.00 (1295.4)

Depth

33.00 (838.2)

Side-by-Side Substation
Height

53.00 (1346.2)

Width

66.00 (1676.4)

Depth

30.00 (762.0)

Double Panel Substation
Height

53.00 (1346.2)

Width

63.00 (1600.2)

Depth

33.00 (838.2)

6
6
6
6
6
6
6
6
6
6
6
6
V1-T6-88

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Power Pedestals
Marina Power and Lighting Equipment

6.5

Contents

Panels

Description

Panel (Stainless Steel Shown)

Page

Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . .
Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . .
Hatteras Light . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mariner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters . . . . . . . . .
Distribution Equipment—Ground Fault Monitor . .
Distribution Equipment—Mega Yacht Powerpoint
Distribution Equipment—Substations . . . . . . . . . .
Distribution Equipment—Panels
Distribution Equipment—Transformers . . . . . . . . .

V1-T6-51
V1-T6-54
V1-T6-58
V1-T6-62
V1-T6-65
V1-T6-69
V1-T6-73
V1-T6-79
V1-T6-80
V1-T6-81
V1-T6-82
V1-T6-83
V1-T6-86
V1-T6-90

6
6
6
6
6
6
6
6
6
6
6
6
6
6

Distribution Equipment—Panels
Product Description

Features

Two of the many products
we can offer our customers
are Eaton’s PRL-3A and
PRL-4 panels as standalone
units or in one of our
substations. All of our busses
are made of copper and are
load rated; breakers are
bolt-on type. Distribution
panels can be 120/240V
single-phase, 120/208V threephase, 277/480V three-phase
or 220Y/127V three-phase
based on your system
requirements. Distribution
panels can also have a main
breaker or a main lug. Branch
circuit breakers are provided
based on customer
requirements.

●

●
●

All internal wiring is
fine stranded 1000V
insulated copper
Copper busbars
All exterior hardware
is stainless steel

Available Options
●
●

●
●
●
●

NEMA 3R or 4X
Powder-coated
stainless steel
Main breaker up to 1200A
Branch breaker 20–1200A
Main lug only
We also offer 480V
models—single-phase
and three-phase

Standards and Certifications
●
●

UL listed
cULus listed

6
6
6
6
6
6

Single-Phase
●
Up to 1200A main
circuit breakers
●
Up to 42 branch
circuit breakers

6
6
6

Three-Phase
●
Up to 1200A main
circuit breakers
●
Up to 42 branch
circuit breakers

6
6
6
6
6
6
6

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

V1-T6-89

6.5
6

Power Pedestals
Marina Power and Lighting Equipment

Contents

Transformers

Description

6
6
6
6
6
6
6
6

Three-Phase Transformer

6

Page

Power Pedestals. . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . .
Hatteras Light. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mariner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Digital Electronic Kilowatthour Meters . . . . . . . . . .
Distribution Equipment—Ground Fault Monitor. . .
Distribution Equipment—Mega Yacht Powerpoint .
Distribution Equipment—Substations . . . . . . . . . .
Distribution Equipment—Panels . . . . . . . . . . . . . .
Distribution Equipment—Transformers

V1-T6-51
V1-T6-54
V1-T6-58
V1-T6-62
V1-T6-65
V1-T6-69
V1-T6-73
V1-T6-79
V1-T6-80
V1-T6-81
V1-T6-82
V1-T6-83
V1-T6-86
V1-T6-89

6
6
6
6

Distribution Equipment—Transformers

6

Product Description

Features

Because of the high humidity
and corrosive conditions of
coastal environments, our
transformers are wound with
Class H heavily insulated
copper bar and are double
dipped in tough insulating
varnish that protects the
copper, as well as reduces
the hum that is typical in
a transformer that is not
double dipped. We provide
a second overcoat of high
temperature epoxy to protect
against the severe saltwater
environment. We can provide
this transformer in singlephase, from 50–500 kVA,
and three-phase, from
45–300 kVA.

●

6
6
6
6
6
6
6
6
6
6

●

●
●

●

Copper wound transformer
coils double dipped in high
temperature baking varnish
All internal wiring is
fine stranded 2000V
insulated copper
Copper busbars
Marine transformers
with epoxy overcoat
All copper-to-copper
connections

Available Options
●
●
●

Single-phase: 50–500 kVA
Three-phase: 45–300 kVA
Epoxy overcoat for nonmarine applications

Primary Voltages
●
480 wye three-phase
●
480V three-phase delta
three-wire + ground
●
480V single-phase
two-wire + ground
Secondary Voltages
●
127/220V three-phase
wye four-wire
●
120/208V three-phase
wye four-wire
●
120/240V single-phase
three-wire
Marina Power Distribution
Transformer kVA Availabilities
●
Single-phase: 50, 75, 100,
150, 167.5, 200, 250, 330,
500 kVA
●
Three-phase: 45, 75, 112.5,
150, 225, 300 kVA

6
6
6
6
6
V1-T6-90

Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com

Standards and Certifications
●

cULus listed

Air Conditioning Disconnects
Air Conditioning Disconnects

7.1

Air Conditioning Disconnects
Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Application Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Features, Benefits and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Standards and Certifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cross-Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

V1-T7-2
V1-T7-2
V1-T7-3
V1-T7-3
V1-T7-4
V1-T7-6
V1-T7-7
V1-T7-7

7
7
7
7
7
7
7

Learn
Online

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

Volume 1—Residential and Light Commercial

CA08100002E—August 2012

www.eaton.com

V1-T7-1

7.1
7

Air Conditioning Disconnects
Fused, Unfused and Molded Case Switch

Contents

Air Conditioning Disconnects

Description

7

Page

Features, Benefits and Functions. . . . . . . . . . . . . .
Standards and Certifications . . . . . . . . . . . . . . . . .
Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . .
Cross-Reference . . . . . . . . . . . . . . . . . . . . . . . . . .
Technical Data and Specifications . . . . . . . . . . . . .
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7
7
7
7
7
7

Complete Line of Fused, Unfused and Molded
Case Switch Type Air Conditioning Disconnects

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

Product Description
An air conditioning
disconnect (ACD) is a
disconnect located between
a loadcenter (distribution
panel) and air conditioner.
Eaton’s ACD product line
provides an installer or repair
personnel with a visible
disconnecting means when
performing maintenance.
ACDs are also known as
disconnects, pullouts or air
conditioning switches.
Non-fused pullout and
molded case switch devices
provide personnel with a
visible ON-OFF disconnecting
means. While fused pullout
units also perform this
function, they also provide an
additional level of protection
for the air conditioner.
Fused and non-fused devices
are of a pullout design, where
the user physically removes
or “pulls out” a tab to break
the electrical connection.
A molded case switch is
similar to a light switch where
the user “switches” the
unit to the indicated
ON-OFF position.

Application Description
Fused and Non-Fused
Pullouts
●

●

●

ON/OFF control provided
by a pullout handle
Pullout handle can be
conveniently stored in the
compartment in the OFF
position, helping to prevent
the handle from being
misplaced
Protective shield cannot be
removed until the pullout
handle is removed,
disconnecting the power

Molded Case Switch
●

●

●

Rugged molded case
construction in a
disconnect switch that
looks like a circuit breaker
but operates like an
ordinary household
light switch
Plug-in molded case switch
(included) eliminates the
need for pullout handles
No need for replacement
pullout handles due to loss
or theft

The most widely used
application for ACDs is for
residential and light
commercial air conditioning
units. An ACD is installed
outdoors, in visible proximity
to the air conditioner
condensing unit. ACDs are
also found in use with heat
pumps, swimming pools,
spas, whirlpools and pump
houses, and meet 2008
NEC Article 422.31 (B)
requirements for servicing
electric water heaters.
Metallic enclosures are
galvanized steel and are
installed in various locations.
Non-metallic enclosures are a
plastic (polycarbonate)
enclosure commonly used in
coastal or salt-water areas.

7
7
7
7
V1-T7-2

Volume 1—Residential and Light Commercial

CA08100002E—August 2012

www.eaton.com

V1-T7-3
V1-T7-3
V1-T7-4
V1-T7-6
V1-T7-7
V1-T7-7

Air Conditioning Disconnects
Fused, Unfused and Molded Case Switch

Features, Benefits and Functions
●

●

●

●

●

●

●

●

Single-phase, two-wire,
240 Vac and three-phase,
three-wire, 240 Vac
NEMA 3R outdoor
enclosures offered in
metallic and
non-metallic versions
Easy-to-remove highstrength protective
shield for easier wiring
and mounting
Easy-to-remove front cover
(no screws or fasteners to
remove)
1-inch knockouts on the
bottom, back and side
of unit
Copper-rated line and load
lugs that are easily
accessible
Ample wiring space for
mounting with a stud gun
(single keyhole, two- or
three-point mounting)
Fused devices are service
entrance rated

●

●

●

●

●

●

●

Horsepower rated (10 hp
maximum at 240 Vac)
Padlockable door provision
for safety and reduction of
tampering
Metallic enclosures are
bottom entry and exit only
Non-metallic enclosures
have knockouts and a hub
provision for top access
Non-metallic enclosures
have a single unit door and
protective shield for
installer convenience
Non-metallic enclosures
are durable and provide
excellent resistance to
climate changes
Factory-installed tamperresistant/weather-resistant
receptacles are available as
an option on some products

7.1

Standards and
Certifications
●

7
7

UL listed File No. E132354,
E143893, E196365

7
7
Contact Eaton for details
and part numbers for CSA
approved units.

7
7
7
7
7
7
7
7
7

Note: Fused non-metallic units
require the addition of GB4NM
ground bar to obtain a Service
Entrance rating.

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
7
Volume 1—Residential and Light Commercial

CA08100002E—August 2012

www.eaton.com

V1-T7-3

7.1
7
7

Fused, Unfused and Molded Case Switch

Product Selection
DPU222R

7

Non-Fused Pullouts
Main
Ampere
Rating

7

Maximum hp Rating
120V

240V

Wire Size
Range Cu/Al
60ºC or 75ºC

—

10

#14–3

DPU222R 1

#14–2

ACD222URNM-A2 1

Catalog
Number

Catalog
Number

Galvanized Steel

7

60

Non-Metallic/Polycarbonate Enclosure

7

60

7
7

Air Conditioning Disconnects

DPF222R

10

Fused Pullouts
Main
Ampere
Rating

7

—

Maximum hp Rating
120V

240V

Wire Size
Range Cu/Al
60ºC or 75ºC

Galvanized Steel

7

30 2

2

3

#14–3

DPF221R 1

7

60 2

3

10

#14–3

DPF222R 1

Non-Metallic
30

2

3

#14–2

ACD221RNM-A2 1

60

3

10

#14–2

ACD222RNM-A2 1

Catalog
Number

7
7
7
7

For Service Entrance applications, see footnotes below.

DPB222R

Molded Case Switch
Main
Ampere
Rating

7

Maximum hp Rating
120V

240V

Wire Size
Range Cu/Al
60ºC or 75ºC

—

10

#14–3

DPB222R 3

#14–2

B60NARNM-A2 3

Galvanized Steel

7

60

Non-Metallic/Polycarbonate Enclosure

7

60

7

—

10

Notes
1 For replacement pullout head, order part number 96-3258-4.
2 To obtain a Service Entrance Rating, the addition of a DPFG (ground bar kit) is required.
3 For replacement molded case switch, order part number BR260NA.

7
7
7
7
7
7
7
7
7
7
7
V1-T7-4

Volume 1—Residential and Light Commercial

CA08100002E—August 2012

www.eaton.com

Air Conditioning Disconnects
Fused, Unfused and Molded Case Switch

DPU222RGF20

7.1

ACD with 20 Ampere Ground Fault Receptacle 1
Main
Ampere
Rating

Maximum hp Rating
120V

7

240V

Wire Size
Range Cu/Al
60ºC or 75ºC

Catalog
Number

7

Non-Fused Pullouts
60

—

10

#14–3

DPU222RGF20WRTR 2

60

—

10

#14–3

DPU222RGF20

30

2

3

#14–3

DPF221RGF20WRTR 2

30

2

3

#14–3

DPF221RGF20

60

3

10

#14–3

DPF222RGF20WRTR 2

60

3

10

#14–3

DPF222RGF20

7
7

Fused Pullouts

DPU222RGF15

7
7
7
7

ACD with 15 Ampere Ground Fault Receptacle 13
Main
Ampere
Rating

Maximum hp Rating
120V

240V

Wire Size
Range Cu/Al
60ºC or 75ºC

Catalog
Number

7
7

Non-Fused Pullouts
60

—

10

#14–3

DPU222RGF15

60

—

10

#14–3

DPU222RGF15WRTR 2

30

2

3

#14–3

DPF221RGF15

30

2

3

#14–3

DPF221RGF15WRTR 2

60

3

10

#14–3

DPF222RGF15

60

3

10

#14–3

DPF222RGF15WRTR 2

7
7

Fused Pullouts

7
7
7

Notes
1 Factory-installed GFCI receptacle.
2 Includes weather-resistant/tamper-resistant receptacles to meet 2008 NEC Article 406.8 (A) and 406.11 requirements.
3 NEC permits the maximum receptacle rating of a 15A circuit to be 15A.

7
7
7
7
7
7
7
7
7
7
7
7
7
7
7

Volume 1—Residential and Light Commercial

CA08100002E—August 2012

www.eaton.com

V1-T7-5

7.1
7

DPU362A

7
7

Air Conditioning Disconnects
Fused, Unfused and Molded Case Switch

Three-Phase Non-Fused ACD
Main
Ampere
Rating

Maximum hp Rating
240V

480V

Wire Size
Range Cu 75ºC

Catalog
Number

60

15

30

#14–4

DPU362RA

7
7
7
7

Cross-Reference
Cross-Reference

7
7

Catalog Number
Description

Eaton

Square D®

GE®

Siemens®
(Murray®)

Milbank

Midwest

Metallic/Galvanized Steel Enclosure

7

30A fused

DPF221R

—

TF30R

WF2030

U3830

U035F2

7

60A fused

DPF222R

—

TF60R

WF2060

U3860

U065F1

60A non-fused

DPU222R

—

TFN60R

—

U3800

U065P010

60A non-fused compact design

DPU222R

—

—

WNFC2060

—

—

60A molded case switch

DPB222R

QO200TR

TNA60R1

WNAS2060

—

U065NA1

7

60A non-fused with ground fault receptacle

DPU222RGF

—

TFN60RGFR

WN2060GFCI

U3822-20GR

U065P010

7

30A fused with ground fault receptacle

DPF221RGF

—

—

WF2030GFCI

—

U035F010

60A fused with ground fault receptacle

DPF222RGF

—

—

WF2060GFCI

—

U065F010

60A non-fused with 1/2-inch wire harness

DPU222R12W

—

—

—

—

—

60A non-fused with 3/4-inch wire harness

DPU222R34W

—

—

—

—

—

60A three-phase 600V molded case switch

DPU362RA

—

—

—

—

U0653F

7

7
7
7

Non-Metallic/Polycarbonate Enclosure
30A fused

ACD221RNM-A2

TPF30R

WF2030PL

—

P035F

60A fused

ACD222RNM-A2

TPF60R

WF2060PL

—

P065F

60A non-fused

ACD222URNM-A2

TPN60R1

WN2060PL

—

P065P1

7

60A molded case switch

B60NARNM-A2

QO200TRNM

TPNA60R1

WNAS2060PL

—

P065NA1

7

30A fused with 15A ground fault receptacle

DPF221RGF15WRTR

—

—

—

—

—

30A fused with 20A ground fault receptacle

DPF221RGF20WRTR

—

—

—

—

—

7

60A fused with 15A ground fault receptacle

DPF222RGF15WRTR

—

—

—

—

—

60A fused with 20A ground fault receptacle

DPF222RGF20WRTR

—

—

—

—

—

7

60A non-fused with 15A ground fault receptacle

DPU222RGF15WRTR

—

—

—

—

—

60A non-fused with 20A ground fault receptacle

DPU222RGF20WRTR

—

—

—

U3822-20GWR

—

7

7
7

Note
1 Eaton Quick ProSM designated item.

7
7
7
7
7
7
V1-T7-6

Volume 1—Residential and Light Commercial

CA08100002E—August 2012

www.eaton.com

Air Conditioning Disconnects
Fused, Unfused and Molded Case Switch

7.1

Technical Data and Specifications
●

●
●

●

10,000 amperes rms
symmetrical interrupting
rating
Horsepower rated
Fusible and non-fusible
pullout and molded case
switch designs
30 and 60 amperes
available in fusible

●

●

●

7

60 amperes available in
non-fusible and molded
case switch
Class H fuse clips provided
on fusible pullout design
WRTR (weather-resistant/
tamper-resistant)
receptacle options
available

7
7
7
7
7

Dimensions
Approximate Dimensions in Inches (mm)

7

Dimensions and Shipping Carton Information

7

Catalog Number

Carton
Quantity

7

Dimensions in Inches (mm)
Height

Width

Depth

Weight Lbs (kg)

7

Metallic/Galvanized Steel Enclosure
DPF221R

10

8.70 (220.9)

5.40 (137.2)

3.15 (80.0)

27 (12)

DPF222R

10

8.70 (220.9)

5.40 (137.2)

3.15 (80.0)

27 (12)

DPU222R

10

8.70 (220.9)

5.40 (137.2)

3.15 (80.0)

27 (12)

DPB222R

10

8.60 (218.4)

5.30 (134.6)

3.74 (95.0)

34 (15)

DPU222R12W 1

1

14.75 (374.6)

12.50 (317.5)

4.00 (101.6)

6 (3)

DPU222R34W 1

1

14.75 (374.6)

12.50 (317.5)

4.00 (101.7)

6 (3)

DPU222RGF20

1

13.00 (330.2)

7.50 (190.5)

4.75 (120.7)

8 (4)

DPF221RGF20

1

13.00 (330.2)

7.50 (190.5)

4.75 (120.7)

8 (4)

DPF222RGF20

1

13.00 (330.2)

7.50 (190.5)

4.75 (120.7)

8 (4)

DPU222RGF15

1

13.00 (330.2)

7.50 (190.5)

4.75 (120.7)

8 (4)

DPF221RGF15

1

13.00 (330.2)

7.50 (190.5)

4.75 (120.7)

8 (4)

DPF222RGF15

1

13.00 (330.2)

7.50 (190.5)

4.75 (120.7)

8 (4)

DPF221RGF15WRTR

1

13.00 (330.2)

7.50 (190.5)

4.75 (120.7)

8 (4)

DPF221RGF20WRTR

1

13.00 (330.2)

7.50 (190.5)

4.75 (120.7)

8 (4)

DPF222RGF15WRTR

1

13.00 (330.2)

7.50 (190.5)

4.75 (120.7)

8 (4)

DPF222RGF20WRTR

1

13.00 (330.2)

7.50 (190.5)

4.75 (120.7)

8 (4)

7
7
7
7
7
7
7
7
7
7

DPU222RGF15WRTR

1

13.00 (330.2)

7.50 (190.5)

4.75 (120.7)

8 (4)

DPU222RGF20WRTR

1

13.00 (330.2)

7.50 (190.5)

4.75 (120.7)

8 (4)

DPU362R

1

8.60 (218.4)

5.30 (134.6)

3.74 (94.9)

4 (2)

7

8.63 (219.0)

6.26 (159.0)

4.33 (109.9)

15 (7)

7

Non-Metallic/Polycarbonate Enclosure
ACD221RNM-A2

10

ACD222RNM-A2

10

8.63 (219.0)

6.26 (159.0)

4.33 (109.9)

15 (7)

ACD222URNM-A2

10

8.63 (219.0)

6.26 (159.0)

4.33 (109.9)

15 (7)

B60NARNM-A2

10

8.63 (219.0)

6.26 (159.0)

4.33 (109.9)

18 (8)

7
7

Note
1 Eaton Quick Pro designated item.

7
7
7
7
7
7
Volume 1—Residential and Light Commercial

CA08100002E—August 2012

www.eaton.com

V1-T7-7

7.1

Air Conditioning Disconnects
Fused, Unfused and Molded Case Switch

7

Approximate Dimensions in Inches (mm)

7

DPF221R, DPF222R, DPU222R, DPU222R12W and DPU222R34W

7

4.00
(101.6)

7

3.15
(80.1)

7

5.40
(137.2)

7
7

2.00
(50.8)
0.25
(6.4)

2.54
(64.4)
1.11
(28.2)

1.47
(37.2)

7
7

5.14
(130.6)

7

8.79
(223.4)

7

8.70
(221.0)

5.26
(133.6)

7
7

0.26 (6.5) Dia.
3 Holes Req’d.

7

1.65
(41.9)

7
5.25
(133.5)

7

1.09
(27.7)

1.13
(28.7)

7

1.00
(25.4)

2.97
(75.3)

7

7 Knockouts for 1/2 (12.7),
3/4 (19.1) or 1 (25.4) Conduit

7
7

1.13
(28.7)

7

1.50
(38.1)

7

1.05
(26.7)

7

3.00
(76.2)

0.55
(14.0)
0.28 (7.1) Diameter
Knockout—1 Req‘d.

7
7
7
7
7
7
V1-T7-8

Volume 1—Residential and Light Commercial

CA08100002E—August 2012

1.55
(39.4)

5.10
(129.5)

2.39
(60.8)

7

1.55
(39.4)

www.eaton.com

7.1

Air Conditioning Disconnects
Fused, Unfused and Molded Case Switch

Approximate Dimensions in Inches (mm)

7

ACD221RNM-A2, ACD222RNM-A2, ACD222URNM-A2 and B60NARNM-A2

7

6.26
(159.0)

4.33
(110.2)

7

0.90
(22.9)

0.20
(5.1) DIA.

7
7
7

7.03
(178.7)
8.69
(220.8)

8.36
(212.2)
0.96
(24.4)

7
7

0.21
(5.3)
DIA.
1.00
(25.4)

7
7

1 Knockout
for 0.50 (12.7),
1.00 (25.4),
1.25 (31.8)
Conduit

1.83
(46.4)

1.35
(34.3)
4.08
(103.6)

0.81
(20.6)
1.05
(26.5)

1.95
(49.5)

4.20
(106.6)

1.76
(44.7)
3.52
(89.3)

7

6.00
(152.4)

7
7

4 Knockouts
for 0.75 (19.1)
or 1.00 (25.4)
Conduit

1.35
(34.3)
1.36
(34.5)

7

1.95
(49.5)

2 Knockouts
for 0.50 (12.7),
0.75 (19.1)
or 1.00 (25.4)
Conduit

7
7
7

DPB222R and DPU362A

7
7
7
7
7

8.60
(218.4)

7
7
7
3.74
(94.9)

7
7
7
7

5.30
(134.6)

7
Volume 1—Residential and Light Commercial

CA08100002E—August 2012

www.eaton.com

V1-T7-9

7.1

Air Conditioning Disconnects
Fused, Unfused and Molded Case Switch

7

Approximate Dimensions in Inches (mm)

7

DPU222RGF20, DPF221RGF20, DPF222RGF20, DPU222RGF15, DPF221RGF15, DPF222RGF15, DPF221RGF15WRTR,
DPF221RGF20WRTR, DPF222RGF15WRTR, DPF222RGF20WRTR, DPU222RGF15WRTR and DPU222RGF20WRTR

7

6.63
(168.4)

7

4.44
(112.8)

0.25 (6.4) Dia.
Hole 3 Places

7
7
7
7
7
7

LINE

LINE

11.63
(295.4)

10.25
(260.4)

7

8.75
(222.3)

7
7

2.31
(58.7)

7
7
7

1.44
(36.6)

0.75, 1.00, 1.25, 1.50
(19.1, 25.4, 31.8, 38.1)
Knockouts
20A GFCI
Receptacle

7
7

1.18
(30.0)
1.69
(42.9)
0.69
(17.5)

0.50, 0.75, 1.00
(12.7, 19.1, 25.4)
Knockouts

5.13
(130.3)
6.25
(158.8)

7

4.06
(103.1)

1.25
(31.8)

0.50, 0.75
(12.7, 19.1)
Knockouts

0.94
(23.9)

7

4.44
(112.8)

7
7
7
7
7
7
7
7
7
7
V1-T7-10

Volume 1—Residential and Light Commercial

CA08100002E—August 2012

4.31
(109.5)

www.eaton.com

Appendix 1—Eaton Terms & Conditions
Effective Date: November 1, 2008

Contents

Eaton Terms & Conditions

Description

Page

Terms and Conditions of Sale. . . . . . . . . . . . . . . . .
Terms of Payment . . . . . . . . . . . . . . . . . . . . . . . . .
Freight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

V1-A1-1
V1-A1-2
V1-A1-3
V1-A1-3

Selling Policy (Supersedes Selling Policy 25-000, dated February 20, 2006)
Terms and Conditions of Sale
The Terms and Conditions of
Sale set forth herein, and any
supplements which may be
attached hereto, constitute
the full and final expression
of the contract for the sale
of products or services
(hereinafter referred to as
Product(s) or Services by
Eaton Corporation
(hereinafter referred to as
Seller) to the Buyer, and
supersedes all prior
quotations, purchase orders,
correspondence or
communications whether
written or oral between the
Seller and the Buyer.
Notwithstanding any contrary
language in the Buyer’s
purchase order,
correspondence or other
form of acknowledgment,
Buyer shall be bound by
these Terms and Conditions
of Sale when it sends a
purchase order or otherwise
indicates acceptance of this
contract, or when it accepts
delivery from Seller of the
Products or Services.

THE CONTRACT FOR SALE
OF THE PRODUCTS OR
SERVICES IS EXPRESSLY
LIMITED TO THE TERMS
AND CONDITIONS OF SALE
STATED HEREIN. ANY
ADDITIONAL OR DIFFERENT
TERMS PROPOSED BY
BUYER ARE REJECTED
UNLESS EXPRESSLY
AGREED TO IN WRITING BY
SELLER. No contract shall
exist except as herein
provided.
Complete Agreement
No amendment or
modification hereto nor any
statement, representation or
warranty not contained herein
shall be binding on the Seller
unless made in writing by an
authorized representative of
the Seller. Prior dealings,
usage of the trade or a course
of performance shall not be
relevant to determine the
meaning of this contract even
though the accepting or
acquiescing party had
knowledge of the nature
of the performance and
opportunity for objection.

Quotations
Written quotations are valid
for 30 days from its date
unless otherwise stated in
the quotation or terminated
sooner by notice.
Verbal quotations, unless
accepted, expire the same
day they are made.
A complete signed order
must be received by Seller
within 20 calendar days of
notification of award,
otherwise the price and
shipment will be subject to
re-negotiation.

Volume 1—Residential and Light Commercial CA08100002E—June 2013

Termination and Cancellation
Any order may be terminated
by the Buyer only by written
notice and upon payment
of reasonable termination
charges, including all costs
plus profit.
Seller shall have the right to
cancel any order at any time
by written notice if Buyer
breaches any of the terms
hereof, becomes the subject
of any proceeding under state
or federal law for the relief
of debtors, or otherwise
becomes insolvent or
bankrupt, generally does not
pay its debts as they become
due or makes an assignment
for the benefit of creditors.

www.eaton.com

V1-A1-1

Appendix 1—Eaton Terms & Conditions
Effective Date: November 1, 2008

Prices
All prices are subject to
change without notice. In the
event of a price change, the
effective date of the change
will be the date of the new
price or discount sheet, letter
or telegram. All quotations
made or orders accepted
after the effective date will be
on the new basis. For existing
orders, the price of the
unshipped portion of an order
will be the price in effect at
time of shipment.
Price Policy—Products and
Services
When prices are quoted as
firm for quoted shipment, they
are firm provided the following
conditions are met:
1. The order is released
with complete
engineering details.
2. Shipment of Products are
made, and Services
purchased are provided
within the quoted
lead time.
3. When drawings for
approval are required
for any Products, the
drawings applicable to
those Products must be
returned within 30*
calendar days from the
date of the original
mailing of the drawings
by Seller. The return
drawings must be
released for manufacture
and shipment and must
be marked “APPROVED”
or “APPROVED AS
NOTED.” Drawing
re-submittals which are
required for any other
reason than to correct
Seller errors will not
extend the 30-day period.

If the Buyer initiates or in
any way causes delays
in shipment, provision of
Services or return of approval
drawings beyond the periods
stated above, the price of the
Products or Services will be
increased 1% per month
or fraction thereof up to a
maximum of 18 months from
the date of the Buyer’s order.
For delays resulting in
shipment or provision of
Services beyond 18 months
from the date of the Buyer’s
order, the price must be
renegotiated.
Price Policy—BLS
Refer to Price Policy 25-050.
Minimum Billing
Orders less than $1,000 will
be assessed a shipping and
handling charge of 5% of the
price of the order, with a
minimum charge of $25.00
unless noted differently on
Product discount sheets.
Taxes
The price does not include
any taxes. Buyer shall be
responsible for the payment
of all taxes applicable to, or
arising from the transaction,
the Products, its sale, value,
or use, or any Services
performed in connection
therewith regardless of
the person or entity
actually taxed.

Terms of Payment
Products
Acceptance of all orders is
subject to the Buyer meeting
Seller’s credit requirements.
Terms of payment are subject
to change for failure to meet
such requirements. Seller
reserves the right at any time
to demand full or partial
payment before proceeding
with a contract of sale as a
result of changes in the
financial condition of the
Buyer. Terms of Payment are
either Net 30 days from the
date of invoice of each
shipment or carry a cash
discount based on Product
type. Specific payment terms
for Products are outlined in
the applicable Product
discount schedules.
Services
Terms of payment are net
within 30 days from date of
invoice for orders amounting
to less than $50,000.00.
Terms of payment for orders
exceeding $50,000.00 shall
be made according to the
following:
1. Twenty percent (20%) of
order value with the
purchase order payable
30 days from date of
invoice.
2. Eighty percent (80%) of
order value in equal
monthly payments over
the performance period
payable 30 days from
date of invoice.

* 60 days for orders
through contractors
to allow time for their
review and approval
before and after
transmitting them
to their customers.

V1-A1-2

Volume 1—Residential and Light Commercial

CA08100002E—June 2013

www.eaton.com

Except for work performed (i)
under a firm fixed price basis
or (ii) pursuant to terms of a
previously priced existing
contract between Seller and
Buyer, invoices for work
performed by Seller shall
have added and noted on
each invoice a charge of 3%
(over and above the price of
the work) which is related
to Seller compliance with
present and proposed
environmental, health, and
safety regulations associated
with prescribed requirements
covering hazardous materials
management and employee
training, communications,
personal protective
equipment, documentation
and record keeping
associated therewith.
Adequate Assurances
If, in the judgment of Seller,
the financial condition of the
Buyer, at any time during the
period of the contract, does
not justify the terms of
payment specified, Seller
may require full or partial
payment in advance.
Delayed Payment
If payments are not made in
accordance with these terms,
a service charge will, without
prejudice to the right of Seller
to immediate payment, be
added in an amount equal to
the lower of 1.5% per month
or fraction thereof or the
highest legal rate on the
unpaid balance.

Appendix 1—Eaton Terms & Conditions
Effective Date: November 1, 2008

Freight

Warranty

Freight policy will be listed on
the Product discount sheets,
or at option of Seller one of
the following freight terms
will be quoted.

Risk of Loss
Risk of loss or damage to the
Products shall pass to Buyer
at the F.O.B. point.

F.O.B.—P/S—Frt./Ppd. and
Invoiced
Products are sold F.O.B. point
of shipment freight prepaid
and invoiced to the Buyer.

Concealed Damage
Except in the event of F.O.B.
destination shipments, Seller
will not participate in any
settlement of claims for
concealed damage.

F.O.B.—P/S—Frt./Ppd.
and Allowed
Products sold are delivered
F.O.B. point of shipment,
freight prepaid and included
in the price.
F.O.B. Destination—Frt./Ppd.
and Allowed
At Buyer’s option, Seller will
deliver the Products F.O.B.
destination freight prepaid
and 2% will be added to the
net price.
The term “freight prepaid”
means that freight charges
will be prepaid to the
accessible common carrier
delivery point nearest the
destination for shipments
within the United States and
Puerto Rico unless noted
differently on the Product
discount sheets. For any
other destination contact
Seller’s representative.
Shipment and Routing
Seller shall select the point of
origin of shipment, the
method of transportation, the
type of carrier equipment and
the routing of the shipment.
If the Buyer specifies a
special method of
transportation, type of carrier
equipment, routing, or
delivery requirement, Buyer
shall pay all special freight
and handling charges.
When freight is included in
the price, no allowance will
be made in lieu of
transportation if the Buyer
accepts shipment at factory,
warehouse, or freight station
or otherwise supplies its own
transportation.

When shipment has been
made on an F.O.B. destination
basis, the Buyer must unpack
immediately and, if damage is
discovered must:
1. Not move the Products
from the point of
examination.
2. Retain shipping container
and packing material.
3. Notify the carrier in
writing of any apparent
damage.
4. Notify Seller
representative within
72 hours of delivery.
5. Send Seller a copy of
the carrier’s inspection
report.
Witness Tests/Customer
Inspection
Standard factory tests may be
witnessed by the Buyer
at Seller’s factory for an
additional charge calculated
at the rate of $2,500 per day
(not to exceed eight (8) hours)
per Product type. Buyer may
final inspect Products at the
Seller’s factory for $500 per
day per Product type.
Witness tests will add one (1)
week to the scheduled
shipping date. Seller will
notify Buyer fourteen (14)
calendar days prior to
scheduled witness testing
or inspection. In the event
Buyer is unable to attend, the
Parties shall mutually agree
on a rescheduled date.
However, Seller reserves
the right to deem the witness
tests waived with the right to
ship and invoice Products.

Held Orders
For any order held, delayed
or rescheduled at the request
of the Buyer, Seller may, at
its sole option (1) require
payment to be based on any
reasonable basis, including
but not limited to the contract
price, and any additional
expenses, or cost resulting
from such a delay; (2) store
Products at the sole cost and
risk of loss of the Buyer; and/
or (3) charge to the Buyer
those prices under the
applicable price policy.
Payment for such price,
expenses and costs, in any
such event, shall be due by
Buyer within thirty (30) days
from date of Seller’s invoice.
Any order so held delayed or
rescheduled beyond six (6)
months will be treated as a
Buyer termination.

Warranty for Products
Seller warrants that the
Products manufactured by
it will conform to Seller’s
applicable specifications and
be free from failure due to
defects in workmanship and
material for one (1) year from
the date of installation of
the Product or eighteen (18)
months from the date of
shipment of the Product,
whichever occurs first.

Drawing Approval
Seller will design the
Products in line with, in
Seller’s judgment, good
commercial practice. If at
drawing approval Buyer
makes changes outside of
the design as covered in their
specifications, Seller will then
be paid reasonable charges
and allowed a commensurate
delay in shipping date based
on the changes made.

Seller requires all nonconforming Products be
returned at Seller’s expense
for evaluation unless
specifically stated otherwise
in writing by Seller.

Drawing Re-Submittal
When Seller agrees to do so
in its quotation, Seller shall
provide Buyer with the first
set of factory customer
approval drawing(s) at Seller’s
expense. The customer
approval drawing(s) will be
delivered at the quoted
delivery date. If Buyer
requests drawing changes
or additions after the initial
factory customer approval
drawing(s) have been
submitted by Seller, the
Seller, at its option, may
assess Buyer drawing
charges. Factory customer
approval drawing changes
required due to
misinterpretation by Seller
will be at Seller’s expense.
Approval drawings generated
by Bid Manager are excluded
from this provision.

Volume 1—Residential and Light Commercial CA08100002E—June 2013

In the event any Product fails
to comply with the foregoing
warranty Seller will, at its
option, either (a) repair or
replace the defective
Product, or defective part or
component thereof, F.O.B.
Seller’s facility freight
prepaid, or (b) credit Buyer
for the purchase price of the
Product. All warranty claims
shall be made in writing.

This warranty does not
cover failure or damage
due to storage, installation,
operation or maintenance not
in conformance with Seller’s
recommendations and
industry standard practice
or due to accident, misuse,
abuse or negligence. This
warranty does not cover
reimbursement for labor,
gaining access, removal,
installation, temporary power
or any other expenses, which
may be incurred in connection
with repair or replacement.
This warranty does not
apply to equipment not
manufactured by Seller.
Seller limits itself to
extending the same warranty
it receives from the supplier.

www.eaton.com

V1-A1-3

Appendix 1—Eaton Terms & Conditions
Effective Date: November 1, 2008

Extended Warranty for Products
If requested by the Buyer and
specifically accepted in
writing by Seller, the
foregoing standard warranty
for Products will be extended
from the date of shipment for
the period and price indicated
below:
●

●

●

24 months—2% of
Contract Price
30 months—3% of
Contract Price
36 months—4% of
Contract Price

Special Warranty (In and Out)
for Products
If requested by the Buyer
and specifically accepted in
writing by Seller, Seller will,
during the warranty period
for Products, at an additional
cost of 2% of the contract
price, be responsible for the
direct cost of:
1. Removing the Product
from the installed
location.
2. Transportation to the
repair facility and return
to the site.
3. Reinstallation on site.
The total liability of Seller for
this Special Warranty for
Products is limited to 50%
of the contract price of the
particular Product being
repaired and excludes
expenses for removing
adjacent apparatus, walls,
piping, structures, temporary
service, etc.

V1-A1-4

Warranty for Services
Seller warrants that the
Services performed by it
hereunder will be performed
in accordance with generally
accepted professional
standards.
The Services, which do not
so conform, shall be
corrected by Seller upon
notification in writing by the
Buyer within one (1) year
after completion of the
Services.
Unless otherwise agreed to in
writing by Seller, Seller
assumes no responsibility
with respect to the suitability
of the Buyer’s, or its
customer’s, equipment or
with respect to any latent
defects in equipment not
supplied by Seller. This
warranty does not cover
damage to Buyer’s, or its
customer’s, equipment,
components or parts
resulting in whole or in part
from improper maintenance
or operation or from their
deteriorated condition. Buyer
will, at its cost, provide Seller
with unobstructed access
to the defective Services,
as well as adequate free
working space in the
immediate vicinity of the
defective Services and such
facilities and systems,
including, without limitation,
docks, cranes and utility
disconnects and connects,
as may be necessary in order
that Seller may perform its
warranty obligations. The
conducting of any tests shall
be mutually agreed upon and
Seller shall be notified of, and
may be present at, all tests
that may be made.

Volume 1—Residential and Light Commercial

Warranty for Power Systems
Studies
Seller warrants that any
power systems studies
performed by it will conform
to generally accepted
professional standards. Any
portion of the study, which
does not so conform, shall
be corrected by Seller upon
notification in writing by the
Buyer within six (6) months
after completion of the study.
All warranty work shall be
performed in a single shift
straight time basis Monday
through Friday. In the event
that the study requires
correction of warranty items
on an overtime schedule,
the premium portion of such
overtime shall be for the
Buyer’s account.
Limitation on Warranties for
Products, Services and Power
Systems Studies
THE FOREGOING
WARRANTIES ARE
EXCLUSIVE EXCEPT FOR
WARRANTY OF TITLE.
SELLER DISCLAIMS ALL
OTHER WARRANTIES
INCLUDING ANY IMPLIED
WARRANTIES OF
MERCHANTABILITY
AND FITNESS FOR A
PARTICULAR PURPOSE.
CORRECTION OF NONCONFORMITIES IN THE
MANNER AND FOR THE
PERIOD OF TIME PROVIDED
ABOVE SHALL CONSTITUTE
SELLER’S SOLE LIABILITY
AND BUYER’S EXCLUSIVE
REMEDY FOR FAILURE OF
SELLER TO MEET ITS
WARRANTY OBLIGATIONS,
WHETHER CLAIMS OF
THE BUYER ARE BASED
IN CONTRACT, IN TORT
(INCLUDING NEGLIGENCE
OR STRICT LIABILITY), OR
OTHERWISE.

CA08100002E—June 2013

www.eaton.com

Asbestos
Federal Law requires that
building or facility owners
identify the presence,
location and quantity of
asbestos containing material
(hereinafter “ACM”) at work
sites. Seller is not licensed to
abate ACM. Accordingly, for
any contract which includes
the provision of Services,
prior to (i) commencement of
work at any site under a
specific Purchase Order, (ii) a
change in the work scope of
any Purchase Order, the
Buyer will certify that the
work area associated with the
Seller’s scope of work
includes the handling of Class
II ACM, including but not
limited to generator wedges
and high temperature gaskets
which include asbestos
materials. The Buyer shall, at
its expense, conduct
abatement should the
removal, handling,
modification or reinstallation,
or some or all of them, of said
Class II ACM be likely to
generate airborne asbestos
fibers; and should such
abatement affect the cost
of or time of performance
of the work then Seller shall
be entitled to an equitable
adjustment in the schedule,
price and other pertinent
affected provisions of
the contract.
Compliance with Nuclear
Regulation
Seller’s Products are sold as
commercial grade Products
not intended for application in
facilities or activities licensed
by the United States Nuclear
Regulatory Commission for
atomic purposes. Further
certification will be required
for use of the Products in any
safety-related application in
any nuclear facility licensed
by the U.S. Nuclear
Regulatory Commission.

Appendix 1—Eaton Terms & Conditions
Effective Date: November 1, 2008

Returning Products
Authorization and shipping
instructions for the return
of any Products must be
obtained from Seller before
returning the Products.
When return is occasioned
due to Seller error, full credit
including all transportation
charges will be allowed.
Product Notices
Buyer shall provide the user
(including its employees) of
the Products with all Seller
supplied Product notices,
warnings, instructions,
recommendations, and
similar materials.
Force Majeure
Seller shall not be liable for
failure to perform or delay
in performance due to fire,
flood, strike or other labor
difficulty, act of God, act of
any governmental authority or
of the Buyer, riot, embargo,
fuel or energy shortage, car
shortage, wrecks or delays in
transportation, or due to any
other cause beyond Seller’s
reasonable control. In the
event of delay in performance
due to any such cause, the
date of delivery or time for
completion will be extended
by a period of time reasonably
necessary to overcome the
effect of such delay.
Liquidated Damages
Contracts which include
liquidated damage clauses for
failure to meet shipping or job
completion promises are not
acceptable or binding on
Seller, unless such clauses
are specifically accepted in
writing by an authorized
representative of the Seller at
its headquarters office.

Patent Infringement
Seller will defend or, at its
option, settle any suit or
proceeding brought against
Buyer, or Buyer’s customers,
to the extent it is based upon
a claim that any Product or
part thereof, manufactured by
Seller or its subsidiaries and
furnished hereunder,
infringes any United States
patent, other than a claim of
infringement based upon use
of a Product or part thereof in
a process, provided Seller is
notified in reasonable time
and given authority,
information and assistance
(at Seller’s expense) for the
defense of same. Seller shall
pay all legal and court costs
and expenses and courtassessed damages awarded
therein against Buyer
resulting from or incident to
such suit or proceeding. In
addition to the foregoing, if at
any time Seller determines
there is a substantial question
of infringement of any United
States patent, and the use of
such Product is or may be
enjoined, Seller may, at its
option and expense: either (a)
procure for Buyer the right to
continue using and selling the
Product; (b) replace the
Product with non-infringing
apparatus; (c) modify the
Product so it becomes noninfringing; or (d) as a last
resort, remove the Product
and refund the purchase
price, equitably adjusted for
use and obsolescence. In no
case does Seller agree to pay
any recovery based upon its
Buyer’s savings or profit
through use of Seller’s
Products whether the use be
special or ordinary. The
foregoing states the entire
liability of Seller for patent
infringement.

The preceding paragraph
does not apply to any claim of
infringement based upon: (a)
any modification made to a
Product other than by Seller;
(b) any design and/or
specifications of Buyer to
which a Product was
manufactured; or (c) the use
or combination of Product
with other products where
the Product does not itself
infringe. As to the aboveidentified claim situations
where the preceding
paragraph does not apply,
Buyer shall defend and hold
Seller harmless in the same
manner and to the extent as
Seller’s obligations described
in the preceding paragraph.
Buyer shall be responsible for
obtaining (at Buyer’s
expense) all license rights
required for Seller to be able
to use software products in
the possession of Buyer
where such use is required in
order to perform any Service
for Buyer.
With respect to a Product or
part thereof not manufactured
by Seller or its subsidiaries,
Seller will attempt to obtain
for Buyer, from the supplier(s),
the patent indemnification
protection normally provided
by the supplier(s) to
customers.

Volume 1—Residential and Light Commercial CA08100002E—June 2013

Limitation of Liability
THE REMEDIES OF THE
BUYER SET FORTH IN THIS
CONTRACT ARE EXCLUSIVE
AND ARE ITS SOLE
REMEDIES FOR ANY
FAILURE OF SELLER
TO COMPLY WITH ITS
OBLIGATIONS HEREUNDER.
NOTWITHSTANDING
ANY PROVISION IN THIS
CONTRACT TO THE
CONTRARY, IN NO EVENT
SHALL SELLER BE LIABLE
IN CONTRACT, IN TORT
(INCLUDING NEGLIGENCE
OR STRICT LIABILITY) OR
OTHERWISE FOR DAMAGE
TO PROPERTY OR
EQUIPMENT OTHER THAN
PRODUCTS SOLD
HEREUNDER, LOSS OF
PROFITS OR REVENUE,
LOSS OF USE OF
PRODUCTS, COST OF
CAPITAL, CLAIMS OF
CUSTOMERS OF THE
BUYER OR ANY SPECIAL,
INDIRECT, INCIDENTAL OR
CONSEQUENTIAL
DAMAGES WHATSOEVER,
REGARDLESS OF WHETHER
SUCH POTENTIAL
DAMAGES ARE
FORESEEABLE OR IF
SELLER HAS BEEN ADVISED
OF THE POSSIBILITY OF
SUCH DAMAGES.
THE TOTAL CUMULATIVE
LIABILITY OF SELLER
ARISING FROM OR
RELATED TO THIS
CONTRACT WHETHER
THE CLAIMS ARE BASED
IN CONTRACT, IN TORT
(INCLUDING NEGLIGENCE
OR STRICT LIABILITY) OR
OTHERWISE, SHALL NOT
EXCEED THE PRICE OF THE
PRODUCT OR SERVICES
ON WHICH SUCH LIABILITY
IS BASED.

www.eaton.com

V1-A1-5

Appendix 2—Catalog Parent Number Index
A
ACD. . . . . . . . . . .
ACD2. . . . . . . . . .
ARP . . . . . . . . . . .
ARP0 . . . . . . . . . .

C
V1-T7-4, V1-T7-6
V1-T7-4, V1-T7-6
V1-T5-77, V1-T6-8
V1-T5-30, V1-T5-33, V1-T5-85

B
BD . . . . . . . . . . . .
BH . . . . . . . . . . . .
BHG. . . . . . . . . . .
BHL . . . . . . . . . . .
BHT . . . . . . . . . . .
BIN . . . . . . . . . . .
BINA . . . . . . . . . .
BJ . . . . . . . . . . . .
BJH . . . . . . . . . . .
BJL . . . . . . . . . . .
BQ . . . . . . . . . . . .
BQC. . . . . . . . . . .
BR . . . . . . . . . . . .
BRB . . . . . . . . . . .
BRC . . . . . . . . . . .
BRD. . . . . . . . . . .
BRE . . . . . . . . . . .
BRF . . . . . . . . . . .
BRG. . . . . . . . . . .
BRH. . . . . . . . . . .
BRHH . . . . . . . . .
BRL . . . . . . . . . . .
BRL2 . . . . . . . . . .
BRM . . . . . . . . . .
BRP . . . . . . . . . . .
BRQ. . . . . . . . . . .
BRR . . . . . . . . . . .
BRS . . . . . . . . . . .
BRSF . . . . . . . . . .
BRSUR . . . . . . . .
BRW . . . . . . . . . .
BR1 . . . . . . . . . . .
BR2 . . . . . . . . . . .

BR3 . . . . . . . . . . .
BR4 . . . . . . . . . . .
BR5 . . . . . . . . . . .
BR6 . . . . . . . . . . .
BR8 . . . . . . . . . . .
BSS . . . . . . . . . . .
BW . . . . . . . . . . .
BWFP . . . . . . . . .
B424 . . . . . . . . . .
B60N . . . . . . . . . .

V1-T1-80
V1-T1-84
V1-T1-84
V1-T1-84
V1-T1-84
V1-T1-25
V1-T1-22, V1-T1-25, V1-T1-60, V1-T1-91
V1-T1-83, V1-T1-84
V1-T1-83, V1-T1-84
V1-T1-85
V1-T1-80
V1-T1-82
V1-T2-8
V1-T1-26
V1-T1-26
V1-T1-26, V1-T1-81, V1-T1-84
V1-T1-84
V1-T1-60
V1-T1-26, V1-T1-58, V1-T1-65, V1-T1-92
V1-T1-52, V1-T1-76, V1-T1-77, V1-T1-84,
V1-T5-98, V1-T5-125
V1-T1-76, V1-T5-98, V1-T5-125
V1-T1-26, V1-T1-52, V1-T1-60, V1-T1-77,
V1-T1-84
V1-T1-78
V1-T1-60, V1-T1-85
V1-T1-85
V1-T1-84
V1-T1-60
V1-T1-15, V1-T1-52, V1-T1-60, V1-T1-83,
V1-T5-137
V1-T5-137
V1-T1-15, V1-T2-7
V1-T1-83
V1-T1-46–V1-T1-49, V1-T1-51, V1-T1-53, V1-T158, V1-T1-59, V1-T1-76, V1-T1-77, V1-T1-81
V1-T1-46–V1-T1-49, V1-T1-51–V1-T1-52, V1-T158, V1-T1-59, V1-T1-76, V1-T1-81, V1-T1-83, V1T5-98, V1-T5-125, V1-T6-22
V1-T1-46–V1-T1-47, V1-T1-49, V1-T1-51–V1-T152, V1-T1-58, V1-T1-59, V1-T1-77, V1-T1-81
V1-T1-46–V1-T1-49, V1-T1-51–V1-T1-53,
V1-T1-81
V1-T1-57
V1-T1-48
V1-T1-46, V1-T1-48, V1-T1-49, V1-T1-51,
V1-T1-52
V1-T1-22, V1-T1-60
V1-T1-60, V1-T1-94, V1-T5-43
V1-T1-60
V1-T1-47
V1-T7-4, V1-T7-6

CC . . . . . . . . . . .
CCH . . . . . . . . . .
CCL . . . . . . . . . .
CCV . . . . . . . . . .
CCVH . . . . . . . . .
CCV2 . . . . . . . . .
CC3 . . . . . . . . . .
CG . . . . . . . . . . .
CH . . . . . . . . . . .
CHB . . . . . . . . . .
CHE . . . . . . . . . .
CHEC . . . . . . . . .
CHEG . . . . . . . . .
CHF . . . . . . . . . .
CHFL . . . . . . . . .
CHG . . . . . . . . . .
CHH . . . . . . . . . .
CHI. . . . . . . . . . .
CHL . . . . . . . . . .
CHLD . . . . . . . . .
CHLDF . . . . . . . .
CHM . . . . . . . . .
CHMM . . . . . . . .
CHM1 . . . . . . . .
CHM4 . . . . . . . .
CHM5 . . . . . . . .
CHM7 . . . . . . . .
CHN . . . . . . . . . .
CHOU . . . . . . . .
CHP . . . . . . . . . .
CHPA . . . . . . . . .
CHPE . . . . . . . . .
CHPO. . . . . . . . .
CHQ . . . . . . . . . .
CHR . . . . . . . . . .
CHR1 . . . . . . . . .
CHR3 . . . . . . . . .
CHR7 . . . . . . . . .
CHS . . . . . . . . . .
CHSA . . . . . . . . .
CHSPC . . . . . . . .
CHSPF . . . . . . . .
CHSPT . . . . . . . .
CHSP3 . . . . . . . .
CHSUR. . . . . . . .
CHT . . . . . . . . . .
CHTE . . . . . . . . .
CHU . . . . . . . . . .
CHUD. . . . . . . . .
CHU1 . . . . . . . . .
CHU2 . . . . . . . . .
CHU3 . . . . . . . . .
CHU4 . . . . . . . . .
CHU5 . . . . . . . . .
CHU6 . . . . . . . . .
CHU7 . . . . . . . . .

Volume 1—Residential and Light Commercial

V1-T1-38, V1-T1-56, V1-T1-84, V1-T1-95
V1-T1-95
V1-T1-38, V1-T1-84
V1-T1-95, V1-T5-95
V1-T1-95, V1-T5-95, V1-T5-98, V1-T5-135
V1-T5-95, V1-T5-98, V1-T5-125, V1-T5-135
V1-T1-95, V1-T5-135
V1-T5-76
V1-T1-89
V1-T1-22, V1-T1-60, V1-T6-8
V1-T1-16, V1-T1-23
V1-T2-7
V1-T3-14, V1-T3-18
V1-T1-22, V1-T1-32, V1-T1-33
V1-T6-7
V1-T1-25
V1-T1-38
V1-T6-8
V1-T1-11, V1-T1-16, V1-T1-38, V1-T6-8
V1-T6-8
V1-T6-8, V1-T6-9
V1-T1-22, V1-T1-38, V1-T5-41, V1-T6-12,
V1-T6-17
V1-T5-41
V1-T6-12, V1-T6-17
V1-T6-17
V1-T6-12
V1-T6-12
V1-T1-22, V1-T1-25, V1-T6-9
V1-T6-9
V1-T1-24, V1-T1-36–V1-T1-38, V1-T6-23
V1-T6-7, V1-T6-23
V1-T6-7, V1-T6-23
V1-T6-8, V1-T6-9
V1-T2-8
V1-T1-22, V1-T6-12, V1-T6-17
V1-T6-12, V1-T6-17
V1-T6-12
V1-T6-12
V1-T1-15, V1-T1-16, V1-T1-22, V1-T1-25
V1-T2-8
V1-T2-6
V1-T2-6
V1-T2-4–V1-T2-6
V1-T2-6
V1-T2-7
V1-T1-35
V1-T6-7
V1-T5-84, V1-T5-85, V1-T6-11, V1-T6-17
V1-T6-9
V1-T6-11, V1-T6-17
V1-T5-84, V1-T6-11
V1-T6-11
V1-T6-11, V1-T6-17
V1-T6-11
V1-T6-11
V1-T6-11

CA08100002E—April 2014

www.eaton.com

V1-A2-1

Appendix 2—Catalog Parent Number Index
CHVH . . . . . . . . .
CH1 . . . . . . . . . . .

CH2 . . . . . . . . . . .

CH2L . . . . . . . . . .
CH3 . . . . . . . . . . .

CH4 . . . . . . . . . . .
CH4L . . . . . . . . . .
CH5 . . . . . . . . . . .
CH6 . . . . . . . . . . .
CH7 . . . . . . . . . . .
CH8 . . . . . . . . . . .
CH8L . . . . . . . . . .
CH9 . . . . . . . . . . .
CMB . . . . . . . . . .
CMBB . . . . . . . . .
CMBE . . . . . . . . .
CMBX . . . . . . . . .
CSH . . . . . . . . . . .
CSH2 . . . . . . . . . .
CSR . . . . . . . . . . .
CSR2 . . . . . . . . . .
CVH . . . . . . . . . . .
CVH2 . . . . . . . . . .
CVS . . . . . . . . . . .
CVS2 . . . . . . . . . .
CV2 . . . . . . . . . . .
CV3 . . . . . . . . . . .

V1-T5-125
V1-T1-7, V1-T1-10, V1-T1-13, V1-T1-32–V1-T135, V1-T1-37, V1-T1-38, V1-T3-17, V1-T3-18,
V1-T5-84
V1-T1-7–V1-T1-10, V1-T1-11, V1-T1-13, V1-T117, V1-T1-18, V1-T1-32–V1-T1-35, V1-T1-37,
V1-T5-77, V1-T5-84, V1-T5-85
V1-T1-9
V1-T1-7, V1-T1-8, V1-T1-10–V1-T1-14, V1-T1-17,
V1-T1-18, V1-T1-23, V1-T1-32–V1-T1-35,
V1-T3-14
V1-T1-7–V1-T1-14, V1-T1-17, V1-T1-18,
V1-T3-17, V1-T3-18
V1-T1-9
V1-T1-14, V1-T5-85
V1-T1-13, V1-T1-14, V1-T1-17, V1-T3-17,
V1-T3-18
V1-T1-7, V1-T1-10–V1-T1-13, V1-T1-24
V1-T1-7–V1-T1-11, V1-T1-17, V1-T1-18,
V1-T1-23, V1-T1-26, V1-T3-17, V1-T3-18
V1-T1-9
V1-T1-25, V1-T1-38, V1-T1-60
V1-T5-41, V1-T5-42, V1-T5-66
V1-T5-41
V1-T5-50, V1-T5-51, V1-T5-66, V1-T5-86
V1-T5-42
V1-T1-11, V1-T1-16
V1-T1-11, V1-T5-43
V1-T1-11, V1-T1-16, V1-T1-22, V1-T1-52, V1-T194, V1-T5-43, V1-T6-22
V1-T1-11, V1-T1-17, V1-T1-94, V1-T5-43
V1-T5-135
V1-T5-97, V1-T5-98, V1-T5-125
V1-T5-135
V1-T5-97, V1-T5-98, V1-T5-125
V1-T5-97, V1-T5-98, V1-T5-125, V1-T5-135
V1-T5-135

EPBQ . . . . . . . . .
EPBS . . . . . . . . .
EPBT . . . . . . . . .
ESL . . . . . . . . . .
ESWA . . . . . . . .
ESWB . . . . . . . .
ESWC . . . . . . . .
ESWD . . . . . . . .
ESWE. . . . . . . . .
ESWF. . . . . . . . .
ESWI . . . . . . . . .
ESWM . . . . . . . .
ESWN . . . . . . . .
ESWP. . . . . . . . .
ESWR . . . . . . . .
ESWT. . . . . . . . .
ESWV. . . . . . . . .

V1-T5-34
V1-T5-34
V1-T5-34
V1-T5-34
V1-T4-10–V1-T4-13
V1-T4-4, V1-T4-20
V1-T4-15–V1-T4-17
V1-T4-7
V1-T4-12
V1-T4-8, V1-T4-15
V1-T4-14, V1-T4-20
V1-T4-8, V1-T4-9, V1-T4-20
V1-T4-8, V1-T4-9
V1-T4-8, V1-T4-21
V1-T4-18, V1-T4-19
V1-T4-6
V1-T4-5, V1-T4-9

G
GB . . . . . . . . . . .
GBK . . . . . . . . . .
GFC . . . . . . . . . .
GFE . . . . . . . . . .
GHC . . . . . . . . . .
GHQ . . . . . . . . . .
GTAP . . . . . . . . .

V1-T1-25, V1-T1-65, V1-T1-92
V1-T6-9
V1-T1-78, V1-T1-79
V1-T1-79
V1-T6-75
V1-T1-85
V1-T1-58

H
HL . . . . . . . . . . .
HPB . . . . . . . . . .
HPC . . . . . . . . . .
HPP . . . . . . . . . .
HP2 . . . . . . . . . .
HP4 . . . . . . . . . .
HP8 . . . . . . . . . .

V1-T1-84
V1-T5-77
V1-T5-76
V1-T5-77
V1-T5-77
V1-T5-76, V1-T5-77
V1-T5-76

I
D
DPB . . . . . . . . . . .
DPB2 . . . . . . . . . .
DPF . . . . . . . . . . .
DPF2 . . . . . . . . . .
DPU . . . . . . . . . . .
DPU2. . . . . . . . . .
DS . . . . . . . . . . . .
DS1 . . . . . . . . . . .
DS2 . . . . . . . . . . .
DS3 . . . . . . . . . . .
DS9 . . . . . . . . . . .

IMM . . . . . . . . . .
V1-T7-4, V1-T7-6
V1-T7-4, V1-T7-6
V1-T7-4–V1-T7-6
V1-T7-4–V1-T7-6
V1-T7-4–V1-T7-6
V1-T7-4–V1-T7-5
V1-T1-25, V1-T1-65, V1-T6-7
V1-T5-67
V1-T5-67
V1-T5-67
V1-T5-67

E
ECB . . . . . . . . . . .
ECC . . . . . . . . . . .
EDL . . . . . . . . . . .
EGEN. . . . . . . . . .
EGS . . . . . . . . . . .
EHD . . . . . . . . . . .
EPBD. . . . . . . . . .

V1-A2-2

V1-T1-94
V1-T1-95
V1-T5-34
V1-T3-3, V1-T3-4
V1-T3-18
V1-T5-135
V1-T5-34

Volume 1—Residential and Light Commercial

V1-T5-67

J
JT . . . . . . . . . . . .

V1-T6-75

L
LC . . . . . . . . . . .

V1-T1-22, V1-T1-60

M
MBB. . . . . . . . . .
MBE. . . . . . . . . .
MBED . . . . . . . .
MBER . . . . . . . .
MBE1. . . . . . . . .
MBE2. . . . . . . . .
MBE3. . . . . . . . .
MBE4. . . . . . . . .
MBE8. . . . . . . . .
MBH . . . . . . . . .
MBP. . . . . . . . . .
MBT . . . . . . . . . .

CA08100002E—April 2014

V1-T5-41
V1-T5-50, V1-T5-66
V1-T5-60
V1-T5-51
V1-T5-50, V1-T5-51
V1-T5-50, V1-T5-51
V1-T5-51
V1-T5-51
V1-T5-51
V1-T5-67
V1-T5-41
V1-T5-42

www.eaton.com

Appendix 2—Catalog Parent Number Index
MBX . . . . . . . . . .
MB1 . . . . . . . . . .
MB2 . . . . . . . . . .
MB20 . . . . . . . . .
MB4 . . . . . . . . . .
MB5 . . . . . . . . . .
MB8 . . . . . . . . . .
MCB . . . . . . . . . .
MCBK . . . . . . . . .
MHD . . . . . . . . . .
MHM. . . . . . . . . .
MHP . . . . . . . . . .
MHR . . . . . . . . . .
MM . . . . . . . . . . .
MPL. . . . . . . . . . .
MPLFH . . . . . . . .
MSEG . . . . . . . . .
MSL. . . . . . . . . . .
MST. . . . . . . . . . .

V1-T5-41
V1-T5-42
V1-T5-66
V1-T5-42
V1-T5-42
V1-T5-67
V1-T5-42, V1-T5-66
V1-T1-38, V1-T1-84, V1-T1-94, V1-T5-43
V1-T1-94, V1-T5-43
V1-T6-23
V1-T6-22
V1-T6-23
V1-T6-22
V1-T5-137
V1-T6-75–V1-T6-77
V1-T6-77
V1-T2-6, V1-T5-35
V1-T5-140
V1-T5-140

N
NL . . . . . . . . . . . .

V1-T1-22, V1-T1-60

Q
QCD . . . . . . . . . .
QCF . . . . . . . . . . .
QCGF . . . . . . . . .

V1-T1-85
V1-T6-75
V1-T6-75

R
RH . . . . . . . . . . . .
RN . . . . . . . . . . . .
RV . . . . . . . . . . . .

V1-T1-65
V1-T1-18
V1-T6-75, V1-T6-77

S
SPC . . . . . . . . . . .
SP1 . . . . . . . . . . .
SR . . . . . . . . . . . .
SRL . . . . . . . . . . .
ST . . . . . . . . . . . .
STL . . . . . . . . . . .

V1-T1-22, V1-T1-60
V1-T2-4
V1-T1-39, V1-T1-85, V1-T1-94
V1-T1-22, V1-T1-60
V1-T1-39
V1-T5-26

T
TCD . . . . . . . . . . .
TDL . . . . . . . . . . .
TH . . . . . . . . . . . .
TT120 . . . . . . . . .

V1-T1-22, V1-T1-60
V1-T1-22, V1-T1-60
V1-T1-84
V1-T1-21

U
UAHT. . . . . . . . . .
UAST . . . . . . . . . .
UAT . . . . . . . . . . .
UATE . . . . . . . . . .
UATH. . . . . . . . . .
UATR. . . . . . . . . .
UATZ . . . . . . . . . .
UBEH . . . . . . . . .
UBGT. . . . . . . . . .
UBH. . . . . . . . . . .

V1-T5-5
V1-T5-26
V1-T5-20
V1-T5-15
V1-T5-12, V1-T5-13
V1-T5-4–V1-T5-6
V1-T5-6, V1-T5-21
V1-T5-14
V1-T5-15
V1-T5-20, V1-T5-21

UBHR. . . . . . . . .
UBHT . . . . . . . . .
UBTE . . . . . . . . .
UBTH . . . . . . . . .
UBTR . . . . . . . . .
UEHT . . . . . . . . .
UETH . . . . . . . . .
UE7 . . . . . . . . . .
UFHT . . . . . . . . .
UFT . . . . . . . . . .
UFTE . . . . . . . . .
UFTH . . . . . . . . .
UFTR . . . . . . . . .
UGE . . . . . . . . . .
UGHR. . . . . . . . .
UGHT . . . . . . . . .
UGRS . . . . . . . . .
UGTE . . . . . . . . .
UGTH . . . . . . . . .
UGTR . . . . . . . . .
UHI. . . . . . . . . . .
UHIR . . . . . . . . .
UHT . . . . . . . . . .
UHTR . . . . . . . . .
UHTT . . . . . . . . .
UH4 . . . . . . . . . .
UH5 . . . . . . . . . .
UH7 . . . . . . . . . .
UIH. . . . . . . . . . .
ULTS . . . . . . . . .
UNRR. . . . . . . . .
URRS . . . . . . . . .
URS . . . . . . . . . .
URT . . . . . . . . . .
URTR . . . . . . . . .
USTH . . . . . . . . .
USTL . . . . . . . . .
USTS . . . . . . . . .
UST6 . . . . . . . . .
UTE . . . . . . . . . .
UTH . . . . . . . . . .
UTRS . . . . . . . . .
UTTE . . . . . . . . .
UTTH . . . . . . . . .
UTZR . . . . . . . . .
UT2 . . . . . . . . . .
UT3 . . . . . . . . . .
UT4 . . . . . . . . . .
UT5 . . . . . . . . . .
UT6 . . . . . . . . . .
U2R . . . . . . . . . .
U2V . . . . . . . . . .
U3R . . . . . . . . . .
U3V . . . . . . . . . .
U4R . . . . . . . . . .
U5R . . . . . . . . . .
U6R . . . . . . . . . .
U921 . . . . . . . . .

Volume 1—Residential and Light Commercial

V1-T5-5, V1-T5-6, V1-T5-14
V1-T5-5
V1-T5-14
V1-T5-12, V1-T5-13
V1-T5-6
V1-T5-20
V1-T5-14
V1-T5-14
V1-T5-4–V1-T5-5
V1-T5-12, V1-T5-15
V1-T5-14
V1-T5-12
V1-T5-5
V1-T5-15
V1-T5-5
V1-T5-4–V1-T5-6, V1-T5-31
V1-T5-6
V1-T5-14, V1-T5-15
V1-T5-12
V1-T5-4, V1-T5-5, V1-T5-31
V1-T5-20
V1-T5-5
V1-T5-20, V1-T5-21
V1-T5-4–V1-T5-6, V1-T5-28, V1-T5-31
V1-T5-4, V1-T5-6, V1-T5-20
V1-T5-12
V1-T5-12
V1-T5-12
V1-T5-14
V1-T5-26
V1-T5-7
V1-T5-7
V1-T5-4, V1-T5-6, V1-T5-7
V1-T5-22
V1-T5-7
V1-T5-26
V1-T5-26
V1-T5-26
V1-T5-26
V1-T5-14, V1-T5-32
V1-T5-12, V1-T5-13, V1-T5-32
V1-T5-4–V1-T5-7, V1-T5-31
V1-T5-14, V1-T5-15
V1-T5-12
V1-T5-6
V1-T5-20, V1-T5-21
V1-T5-21
V1-T5-20, V1-T5-21
V1-T5-21
V1-T5-21
V1-T5-22
V1-T5-22
V1-T5-20, V1-T5-22
V1-T5-22
V1-T5-20–V1-T5-22
V1-T5-20–V1-T5-22
V1-T5-20
V1-T5-5

CA08100002E—April 2014

www.eaton.com

V1-A2-3

Appendix 2—Catalog Parent Number Index
W
WCG . . . . . . . . . .

V1-T5-136

Numerics
1BPS . . . . . . . . . .
1MCB . . . . . . . . .
1MFS. . . . . . . . . .
1MHC . . . . . . . . .
1MM . . . . . . . . . .
1MMA . . . . . . . . .
1MMB . . . . . . . . .
1MMC . . . . . . . . .
1MMG . . . . . . . . .
1MMJ . . . . . . . . .
1MMM . . . . . . . .
1MMP . . . . . . . . .
1MMR . . . . . . . . .
1MMS . . . . . . . . .
1MMW . . . . . . . .
1MM3 . . . . . . . . .
1MM4 . . . . . . . . .
1MM5 . . . . . . . . .
1MM6 . . . . . . . . .
1MPL. . . . . . . . . .
1MPS . . . . . . . . .
1MP2. . . . . . . . . .
1MP3. . . . . . . . . .
1MP4. . . . . . . . . .
1MP5. . . . . . . . . .
1MP6. . . . . . . . . .
1MTB . . . . . . . . .
1UGP . . . . . . . . . .
1003 . . . . . . . . . .
1004 . . . . . . . . . .
1005 . . . . . . . . . .
1006 . . . . . . . . . .
1007 . . . . . . . . . .
1008 . . . . . . . . . .
1009 . . . . . . . . . .
1010 . . . . . . . . . .
1212 . . . . . . . . . .
1224 . . . . . . . . . .
1624 . . . . . . . . . .
17NE . . . . . . . . . .
1836 . . . . . . . . . .
20NE . . . . . . . . . .
2024 . . . . . . . . . .
24IN. . . . . . . . . . .
24NE . . . . . . . . . .
2424 . . . . . . . . . .
2442 . . . . . . . . . .
2460 . . . . . . . . . .
3BPS . . . . . . . . . .
3BR . . . . . . . . . . .

V1-A2-4

V1-T5-108
V1-T5-104, V1-T5-105
V1-T5-106, V1-T5-107
V1-T5-104, V1-T5-105
V1-T5-115, V1-T5-119, V1-T5-136, V1-T5-137,
V1-T5-139
V1-T5-136
V1-T5-136–V1-T5-140
V1-T5-138
V1-T5-94
V1-T5-137
V1-T5-138
V1-T5-136
V1-T5-138
V1-T5-137
V1-T5-136, V1-T5-139
V1-T5-118, V1-T5-119
V1-T5-118, V1-T5-119
V1-T5-118, V1-T5-119, V1-T5-136
V1-T5-118, V1-T5-119
V1-T5-94
V1-T5-92–V1-T5-94
V1-T5-92, V1-T5-93
V1-T5-92, V1-T5-93
V1-T5-92, V1-T5-93
V1-T5-92, V1-T5-93
V1-T5-92, V1-T5-93
V1-T5-103
V1-T5-107
V1-T5-5, V1-T5-6
V1-T5-5, V1-T5-6, V1-T5-13, V1-T5-20, V1-T5-21,
V1-T5-26
V1-T5-6
V1-T5-6, V1-T5-13, V1-T5-20, V1-T5-28
V1-T5-5, V1-T5-13, V1-T5-15, V1-T5-20,
V1-T5-26
V1-T5-5, V1-T5-6, V1-T5-13, V1-T5-15, V1-T5-20,
V1-T5-21, V1-T5-26, V1-T5-28
V1-T5-5–V1-T5-7, V1-T5-13–V1-T5-15, V1-T5-20,
V1-T5-21, V1-T5-28
V1-T5-12
V1-T1-90
V1-T1-50, V1-T1-90
V1-T1-90
V1-T1-91
V1-T1-90
V1-T1-91
V1-T1-90
V1-T1-90
V1-T1-91
V1-T1-90
V1-T1-50, V1-T1-90
V1-T1-21
V1-T5-108
V1-T1-54–V1-T1-56, V1-T1-60

Volume 1—Residential and Light Commercial

3B42 . . . . . . . . .
3HM . . . . . . . . . .
3MC . . . . . . . . . .
3MCB. . . . . . . . .
3MF . . . . . . . . . .
3MFS . . . . . . . . .
3MHC . . . . . . . .
3MM . . . . . . . . .
3MMB . . . . . . . .
3MME . . . . . . . .
3MM2 . . . . . . . .
3MM3 . . . . . . . .
3MM4 . . . . . . . .
3MM5 . . . . . . . .
3MM6 . . . . . . . .
3MTB . . . . . . . . .
3UGP . . . . . . . . .
304. . . . . . . . . . .
3424. . . . . . . . . .
35MM . . . . . . . .
35NE . . . . . . . . .
35SS . . . . . . . . .
37M . . . . . . . . . .
37MM . . . . . . . .
37SS . . . . . . . . .
4242. . . . . . . . . .
47. . . . . . . . . . . .
48IN . . . . . . . . . .
49. . . . . . . . . . . .
612I . . . . . . . . . .
7821. . . . . . . . . .
7866. . . . . . . . . .
816I . . . . . . . . . .

CA08100002E—April 2014

V1-T1-54
V1-T5-109
V1-T5-109
V1-T5-104, V1-T5-105, V1-T5-109
V1-T5-109
V1-T5-106, V1-T5-107, V1-T5-109
V1-T5-104, V1-T5-105
V1-T5-115, V1-T5-136, V1-T5-137
V1-T5-136
V1-T5-137, V1-T5-139
V1-T5-118–V1-T5-121
V1-T5-118–V1-T5-121
V1-T5-118–V1-T5-121, V1-T5-126
V1-T5-118–V1-T5-121, V1-T5-126
V1-T5-118–V1-T5-121
V1-T5-103
V1-T5-107
V1-T1-90
V1-T1-55
V1-T5-129
V1-T1-91
V1-T5-131
V1-T5-139
V1-T5-130, V1-T5-139, V1-T5-140
V1-T5-131
V1-T1-50, V1-T1-90
V1-T5-138, V1-T5-140
V1-T1-90
V1-T5-138, V1-T5-140
V1-T1-90
V1-T5-13
V1-T5-5
V1-T1-90

www.eaton.com

Appendix 3—Alphabetical Product Index
A
A-BUS Products
StructuredWiringSolutions
“IR” Emitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Audio Distribution Module . . . . . . . . . . . . . . . . . . . .
Audio Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Audio Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cover Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Door Station . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Intercom Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Intercom Module . . . . . . . . . . . . . . . . . . . . . . . . . . .
Interface Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Keypad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Local Input Plate. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Remote Control . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Volume Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

V1-T4-12
V1-T4-11
V1-T4-11
V1-T4-11
V1-T4-13
V1-T4-13
V1-T4-13
V1-T4-12
V1-T4-12
V1-T4-12
V1-T4-11
V1-T4-12
V1-T4-11

Access Panel
Marina Power and Lighting Equipment/RV Park Hook-Ups
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-77
Accessories
Manual Transfer Switches
Flush Flange Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T3-18
Power Inlet Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T3-18
Marina Power and Lighting Equipment/RV Park Hook-Ups
Access Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-77
Breaker Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75
Bus Bar Assembly . . . . . . . . . . . . . . . . . . V1-T6-76, V1-T6-77
Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75
Cover Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75
Digital Electronic Meters . . . . . . . . . . . . . . . . . . . . . V1-T6-76
Door Hasp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-77
External Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-76
Faceplate . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75–V1-T6-77
Fire Extinguisher. . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-77
Fluorescent Light Assembly. . . . . . . . . . . . . . . . . . . V1-T6-75
Fuse Holder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-76
Hose and Cable Brackets . . . . . . . . . . . . . . . . . . . . . V1-T6-75
Isolation Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75
Lens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-77
Life Ring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-77
Light and Lens Assembly . . . . . . . . . . . . . . . . . . . . . V1-T6-75
Light Fuse. . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-76, V1-T6-77
Light Holder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-77
Main Door. . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75, V1-T6-77
Main Housing . . . . . . . . . . . . . . . . . . . . . . V1-T6-75–V1-T6-77
Mounting Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-77
Mounting Feet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-76
Phone, Cable, Internet Assemblies . . . . . . . . . . . . . V1-T6-76
Receptacles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75
Spring Closure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75
Strobe Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-77
Water Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-76
Metering Products
House Panel Accessories. . . . . . . . . . . . . . . . . . . . . V1-T5-77
Meter Socket Accessories . . . . . . . . . . . . . . . . . . . . V1-T5-30
Metering Stack Accessories,
Group Metering . . . . . . . . V1-T5-136, V1-T5-137, V1-T5-139
West Coast All-In-One Design Accessories,
Meter Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-60
Mobile Home Panels. . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-23

Direct Feed Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-23
Padmount Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-23
Pedestal Extension . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-23
StructuredWiringSolutions
Patch Cords. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-21
Surge Protection Devices and Lightning Arresters
3-Pack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T2-6
Flushmount Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T2-6
Outdoor Communication Grounding Device . . . . . . . . V1-T2-6
Quick Connect Design . . . . . . . . . . . . . . . . . . . . . . . . V1-T2-6
Raintight Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T2-6
Temporary Power/RV Park
Cable TV and Telephone Bracket . . . . . . . . . . . . . . . . V1-T6-7
Fluorescent Light Kit . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-7
Pad-Mount Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-7
Pedestal Extension . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-7
Rainproof Conduit Hub . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-7
Renewal Parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-8
Type BR Loadcenters and Circuit Breakers . . . . . . . . . V1-T1-60
Alarm Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-85
Auxiliary Contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-85
Field Installation and Parts . . . . . . . . . . . . . . . . . . . . V1-T1-60
Filler Plates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-60
Ground Bar Kits. . . . . . . . . . . . . . . . . . . . . V1-T1-65, V1-T1-92
Handle Lockoffs . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-84
Handle Ties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-84
Hold-Down Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-84
Main and Sub-Feed Lug Blocks . . . . . . . . . . . . . . . . V1-T1-60
Main Breaker Lug Kits. . . . . . . . . . . . . . . . . . . . . . . . V1-T1-84
Main Lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-60
Mechanical Interlock Covers. . . . . . . . . . . . . . . . . . . V1-T1-63
Mechanical Interlocks . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-85
Rainproof Conduit Hubs . . . . . . . . . . . . . . . . . . . . . . V1-T1-65
Shunt Trip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-85
Type CH Loadcenters and Circuit Breakers . . . . . . . . . V1-T1-22
Decorator Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-26
Field Installation and Parts . . . . . . . . . . . . . . . . . . . . V1-T1-22
Goof Collars . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-26
Ground Bar Kits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-25
Handle Lockdogs . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-38
Handle Lockoffs . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-38
Handle Ties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-38
Hold-Down Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-38
Main Breaker Lug Kits. . . . . . . . . . . . . . . . . . . . . . . . V1-T1-38
Mechanical Interlock Covers. . . . . . . . . . . . . . . . . . . V1-T1-23
Mechanical Interlocks . . . . . . . . . . . . . . . . V1-T1-23, V1-T1-38
Mounting Bases . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-38
Neutral Bar Accessories . . . . . . . . . . . . . . . . . . . . . . V1-T1-25
Phase Adapters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-25
Rainproof Conduit Hubs . . . . . . . . . . . . . . . . . . . . . . V1-T1-25
Shunt Trip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-39
Admiral—SS
Marina Power and Lighting Equipment
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-62
Air Conditioning Disconnects. . . . . . . . . . . . . . . . . V1-T7-1–V1-T7-10
Cross-Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T7-6
Ground Fault Receptacle . . . . . . . . . . . . . . . . . . . . . . . . V1-T7-5
Molded Case Switch . . . . . . . . . . . . . . . . . . . . V1-T7-2, V1-T7-4
Pullouts
Fused . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T7-2, V1-T7-4

Volume 1—Residential and Light Commercial

CA08100002E—April 2014

www.eaton.com

V1-A3-1

Appendix 3—Alphabetical Product Index
Non-Fused . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T7-2, V1-T7-4
Air Cooled Generators
Standby Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T3-3
Air Cooled Standby
Standby Generator System . . . . . . . . . . . . . . . . . . . . . . V1-T3-2
Alarm Contacts
Type BR Loadcenters and Circuit Breakers
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-85
Aluminum Meter Breakers
Metering Products
Meter Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-87
ATS Kit
Automatic Transfer Switches . . . . . . . . . . . . . . . . . . . V1-T3-14
ATS Ready LC with factory-installed ATS kit
Automatic Transfer Switches . . . . . . . . . . . . . . . . . . . V1-T3-14

Breaker Plate
Marina Power and Lighting Equipment/RV Park Hook-Ups
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75
Bus Bar Assembly
Marina Power and Lighting Equipment/RV Park Hook-Ups
Accessories. . . . . . . . . . . . . . . . . . . . . . . . V1-T6-76, V1-T6-77

C
Cable TV and Telephone Bracket
Temporary Power/RV Park
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-7
Camera with IR Emitters
StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . . V1-T4-9
CAT6 Inserts
StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-20

ATS Ready Loadcenter
Automatic Transfer Switches . . . . . . . . . . . . . . . . . . . V1-T3-14

CH Circuit Breakers
Type CH
Loadcenters and Circuit Breakers . . . . . . . . . . . . . . . V1-T1-31

Audio Distribution Module, A-BUS Products
StructuredWiringSolutions . . . . . . . . . . . . . . . . . . . . . V1-T4-11

CH Specialty Products
Non-Metallic Loadcenter . . . . . . . . . . . . . . . . . . . . . . . V1-T1-21

Audio Kit, A-BUS Products
StructuredWiringSolutions . . . . . . . . . . . . . . . . . . . . . V1-T4-11

CH Style Renovation Solutions
Metering Products
Meter Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-86

Audio Module, A-BUS Products
StructuredWiringSolutions . . . . . . . . . . . . . . . . . . . . . V1-T4-11
Audio System Components
StructuredWiringSolutions
Dual Voice Coil Speaker . . . . . . . . . . . . . . . . . . . . . .
In-Wall Speakers. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Outdoor Speakers . . . . . . . . . . . . . . . . . . . . . . . . . .
Rough-In Ring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Round Ceiling Speakers . . . . . . . . . . . . . . . . . . . . . .
Volume Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . .

V1-T4-10
V1-T4-10
V1-T4-10
V1-T4-10
V1-T4-10
V1-T4-10

Automatic Transfer Switches . . . . . . . . . . . . . . . V1-T3-11–V1-T3-15
ATS Ready LC with factory-installed ATS kit. . . . . . . . V1-T3-14
ATS Ready Loadcenter . . . . . . . . . . . . . . . . . . . . . . . . V1-T3-14
ATS Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T3-14
Eaton’s Green Line . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T3-11
Fully Automatic Transfer Switches . . . . . . . . . . . . . . . V1-T3-11
Auxiliary Contact
Type BR Loadcenters and Circuit Breakers
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-85

Circuit Breakers
Marina Power and Lighting Equipment/RV Park Hook-Ups
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75
Clear Plastic Covers
StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-17
Coax Video Modules
StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . . V1-T4-5
Combination Modules
StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . . V1-T4-7
Commercial Lever Bypass Sockets
Metering Products . . . . . . . . . . . . . . . . . . . . V1-T5-10–V1-T5-17
Commercial Meter Stack Modules
Group Metering
Metering Products . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-127
Commercial Safety Sockets
Meter Breakers
Metering Products . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-83

B
Blank Filler Modules
StructuredWiringSolutions . . . . . . . . . . . . . . . . . . . . . . V1-T4-8
Blank Inserts
StructuredWiringSolutions . . . . . . . . . . . . . . . . . . . . . V1-T4-20
Blank Oversized Wall Plates
StructuredWiringSolutions . . . . . . . . . . . . . . . . . . . . . V1-T4-19
Blank Receptacle Wall Plates
StructuredWiringSolutions . . . . . . . . . . . . . . . . . . . . . V1-T4-19
BR Circuit Breakers
BR Specialty Products
Type BR
Loadcenters and Circuit Breakers . . . . . . . . . . . . . V1-T1-75

V1-A3-2

Circuit Breaker Unit Enclosures
Type CH
Loadcenters and Circuit Breakers . . . . . . . . . . . . . . . V1-T1-94

Volume 1—Residential and Light Commercial

Common Trip Quadplex Breakers
Type BR
Loadcenters and Circuit Breakers . . . . . . . . . . . . . . . V1-T1-82
Communications Grounding Device
Metering Products . . . . . . . . . . . . . . . . . . . . V1-T5-35, V1-T5-36
Convertible Loadcenters MCB
Type BR
Loadcenters and Circuit Breakers . . . . . . . . . . . . . . . V1-T1-51
Type CH
Loadcenters and Circuit Breakers . . . . . . . . . . . . . . . V1-T1-11
Convertible Loadcenters MLO
Type BR

CA08100002E—April 2014

www.eaton.com

Appendix 3—Alphabetical Product Index
Loadcenters and Circuit Breakers . . . . . . . . . . . . . . V1-T1-51
Type CH
Loadcenters and Circuit Breakers . . . . . . . . . . . . . . V1-T1-11

D-Marc Box Enclosures
StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-15

Cover Plate, A-BUS Products
StructuredWiringSolutions . . . . . . . . . . . . . . . . . . . . . V1-T4-13

Dome Camera
StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . . V1-T4-9

Cover Set
Marina Power and Lighting Equipment/RV Park Hook-Ups
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75

Door Hasp
Marina Power and Lighting Equipment/RV Park Hook-Ups
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-77

Covers
StructuredWiringSolutions
Clear Plastic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-17
Hinged . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-16
Metal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-15

Door Station, A-BUS Products
StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-13

Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-50

DSL or Cable Router
StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . . V1-T4-9

Cross-Reference
Metering Products . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-31

Dual Voice Coil Speaker
StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-10

D

E

Decorator Cover
Type CH Loadcenters and Circuit Breakers
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-26

Eaton Terms & Conditions. . . . . . . . . . . . . . . . . . . . . . . . . . .
Freight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Limitation of Liability . . . . . . . . . . . . . . . . . . . . . . . . . . .
Terms and Conditions of Sale . . . . . . . . . . . . . . . . . . . .
Terms of Payment . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Digital Electronic Kilowatthour Meters
Marina Power and Lighting Equipment
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-81
RV Park Hook-Ups
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-44
Digital Electronic Meters
Marina Power and Lighting Equipment/RV Park Hook-Ups
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-76
Direct Feed Kit
Mobile Home Panels
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-23
Distribution Equipment—Ground Fault Monitor
Marina Power and Lighting Equipment
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-82
Distribution Equipment—MegaYacht Powerpoint
Marina Power and Lighting Equipment
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-83
Distribution Equipment—Panels
Marina Power and Lighting Equipment
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-89
Power Pedestals
RV Park Hook-Ups . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-49
Distribution Equipment—Substations
Marina Power and Lighting Equipment
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-86
Distribution Equipment—Transformers
Marina Power and Lighting Equipment
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-90
Distribution—Ground Fault Monitor
RV Park Hook-Ups
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-45

V1-T1-1
V1-T1-3
V1-T1-5
V1-T1-1
V1-T1-2
V1-T1-3

Eaton’s Green Line
Automatic Transfer Switches . . . . . . . . . . . . . . . . . . . V1-T3-11
Emergency Generator Panels
Manual Transfer Switches . . . . . . . . . . . . . . V1-T3-16–V1-T3-18
Emergency Power Panels
Manual Transfer Switches . . . . . . . . . . . . . . . . . . . . . . V1-T3-16
Enclosed Breakers
Loadcenters and Circuit Breakers . . . . . . . . V1-T1-93–V1-T1-95
Enclosures
StructuredWiringSolutions
D-Marc Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-15
Install Can . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-14
EUSERC Requirements Service Entrance Devices
Meter Breakers
Metering Products . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-48
External Cover
Marina Power and Lighting Equipment/RV Park Hook-Ups
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-76

F
Faceplate
Marina Power and Lighting Equipment/RV Park Hook-Ups
Accessories. . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75–V1-T6-77
Factory-Installed Surge Protection
Surge Protection Devices and
Lightning Arresters . . . . . . . . . . . . . . . . . . . . V1-T2-2, V1-T2-7

Distribution—Substations
RV Park Hook-Ups
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-46

Field Installation and Parts
Type BR Loadcenters and Circuit Breakers
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-60
Type CH Loadcenters and Circuit Breakers
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-22

Distribution—Transformers
RV Park Hook-Ups

Filler Plates
Type BR Loadcenters and Circuit Breakers

Volume 1—Residential and Light Commercial

CA08100002E—April 2014

www.eaton.com

V1-A3-3

Appendix 3—Alphabetical Product Index
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-60

H

Fire Extinguisher
Marina Power and Lighting Equipment/RV Park Hook-Ups
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-77

Handle Lockdogs
Type CH Loadcenters and Circuit Breakers
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-38

Firehouse
Marina Power and Lighting Equipment
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-73
RV Park Hook-Ups
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-42

Handle Lockoffs
Type BR Loadcenters and Circuit Breakers
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-84
Type CH Loadcenters and Circuit Breakers
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-38

Firewall Router Modules
StructuredWiringSolutions . . . . . . . . . . . . . . . . . . . . . . V1-T4-8
Fluorescent Light Assembly
Marina Power and Lighting Equipment/RV Park Hook-Ups
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75

Handle Ties
Accessories
Type CH Loadcenters and Circuit Breakers . . . . . . . V1-T1-38
Type BR Loadcenters and Circuit Breakers
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-84

Fluorescent Light Kit
Temporary Power/RV Park
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-7

Hatteras Light
Marina Power and Lighting Equipment
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-69

Flush Flange Kit
Manual Transfer Switches . . . . . . . . . . . . . . . . . . . . . V1-T3-18
Flushmount Kit
Surge Protection Devices and Lightning Arresters . . . . V1-T2-6
Fully Automatic Transfer Switches
Automatic Transfer Switches . . . . . . . . . . . . . . . . . . . V1-T3-11
Fuse Holder
Marina Power and Lighting Equipment/RV Park Hook-Ups
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-76

Hinged Covers
StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-16
Hold-Down Kits
Type BR Loadcenters and Circuit Breakers
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-84
Hose and Cable Brackets
Marina Power and Lighting Equipment/RV Park Hook-Ups
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75

Fused, Unfused and Molded Case Switch
Air Conditioning Disconnects . . . . . . . . . . . . V1-T7-2–V1-T7-10

House Panels
Meter Breakers
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-77
Metering Products . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-75

G

I

Goof Collars
Type CH Loadcenters and Circuit Breakers
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-26
Ground Bar Kits
Type BR Loadcenters and Circuit Breakers
Accessories . . . . . . . . . . . . . . . . . . . . . . . V1-T1-65, V1-T1-92
Type CH Loadcenters and Circuit Breakers
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-25

Inserts
StructuredWiringSolutions
Blank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CAT5e . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CAT6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RG6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RJ11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RJ45, CAT5e . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Ground Fault Receptacle
Air Conditioning Disconnects . . . . . . . . . . . . . . . . . . . . V1-T7-5

Install Can Enclosures
StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-14

Group Metering
Metering Products . . . . . . . . . . . . . . . . . . V1-T5-88–V1-T5-147
Accessories . . . . . . . . . . . . . . . . . . . . . V1-T5-136, V1-T5-139
Commercial Meter Stack Modules. . . . . . . . . . . . . V1-T5-127
Main Service Modules . . . . . . . . . . . . . . . . . . . . . . V1-T5-101
Main Tenant Circuit
Breaker . . . . . . V1-T5-96, V1-T5-98, V1-T5-125, V1-T5-134
Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-90
Phase Balanced Stack . . . . . . . . . . . . . . . . . . . . . . V1-T5-126
Renewal Parts . . . . . . . . . . . . . . . . . . . V1-T5-138, V1-T5-140
Residential and Commercial Applications . . . . . . . . V1-T5-88
Residential Meter Stacks . . . . . . . . . . . . . . . . . . . . V1-T5-116
Surge Metering . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-115
Type CCV Tenant Main Circuit Breaker . . . . . . . . . . V1-T5-95

Instrument Rated Sockets
Metering Products . . . . . . . . . . . . . . . . . . . . V1-T5-25, V1-T5-26

V1-A3-4

Volume 1—Residential and Light Commercial

V1-T4-20
V1-T4-20
V1-T4-20
V1-T4-20
V1-T4-20
V1-T4-20

Intercom Kit, A-BUS Products
StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-13
Intercom Module, A-BUS Products
StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-12
Interface Unit, A-BUS Products
StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-12
In-Wall Speakers
StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-10
IR Emitter, A-BUS Products
StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-12

CA08100002E—April 2014

www.eaton.com

Appendix 3—Alphabetical Product Index
Isolation Plate
Marina Power and Lighting Equipment/RV Park Hook-Ups
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75

CH Specialty Products
Non-Metallic Loadcenter . . . . . . . . . . . . . . . . . . . . V1-T1-21
Plug-On Neutral Loadcenter . . . . . . . . . . . . . . . . . . V1-T1-17
Spa Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-14
Surge Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-15
Type CH Renovation Loadcenter . . . . . . . . . . . . . . V1-T1-18
Type CH Retrofit Interior Kits . . . . . . . . . . . . . . . . . V1-T1-19
Circuit Breaker Unit Enclosures . . . . . . . . . . . . . . . . V1-T1-94
Convertible Loadcenters MCB . . . . . . . . . . . . . . . . . V1-T1-11
Convertible Loadcenters MLO . . . . . . . . . . . . . . . . . V1-T1-11
Single-Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-7
Three-Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-12

K
Keypad, A-BUS Products
StructuredWiringSolutions . . . . . . . . . . . . . . . . . . . . . V1-T4-12

L
Lens
Marina Power and Lighting Equipment/RV Park Hook-Ups
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-77
Life Ring
Marina Power and Lighting Equipment/RV Park Hook-Ups
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-77

Local Input Plate, A-BUS Products
StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-11

M

Light and Lens Assembly
Marina Power and Lighting Equipment/RV Park Hook-Ups
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75

Main and Sub-Feed Lug Blocks
Type BR Loadcenters and Circuit Breakers
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-60

Light Fuse
Marina Power and Lighting Equipment/RV Park Hook-Ups
Accessories . . . . . . . . . . . . . . . . . . . . . . . V1-T6-76, V1-T6-77

Main Breaker Lug Kits
Type BR Loadcenters and Circuit Breakers
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-84
Type CH Loadcenters and Circuit Breakers
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-38

Light Holder
Marina Power and Lighting Equipment/RV Park Hook-Ups
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-77
Lighthouse
Marina Power and Lighting Equipment
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-54
Lighthouse—SS
Marina Power and Lighting Equipment
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-58
Liquid Cooled Generator
Standby Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T3-4
Liquid Cooled Standby
Standby Generator System . . . . . . . . . . . . . . . . . . . . . . V1-T3-2
Loadcenter Interiors/OEM Loadcenters
Loadcenters and Circuit Breakers . . . . . . . . V1-T1-88–V1-T1-92
Loadcenters and Circuit Breakers . . . . . . . . . . . . . V1-T1-1–V1-T1-95
Enclosed Breakers . . . . . . . . . . . . . . . . . . . V1-T1-93–V1-T1-95
Loadcenter Interiors/OEM Loadcenters . . . V1-T1-88–V1-T1-92
Type BR . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-42–V1-T1-69
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-60
BR Specialty Products
BR Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-75
Riser Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-58
Spa Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-57
Type BR Renovation Loadcenter . . . . . . . . . . . . . . V1-T1-59
Type BR Retrofit Interior Kits. . . . . . . . . . . . . . . . . V1-T1-72
Common Trip Quadplex Breakers . . . . . . . . . . . . . . V1-T1-82
Convertible Loadcenters MCB . . . . . . . . . . . . . . . . . V1-T1-51
Convertible Loadcenters MLO . . . . . . . . . . . . . . . . . V1-T1-51
Plug-On Circuit Breakers . . . . . . . . . . . . . . . . . . . . . V1-T1-75
Quick-Pro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-59
Single-Phase. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-48
Three-Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-54
Type CH . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-2–V1-T1-28
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-22
CH Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-31

Main Door
Marina Power and Lighting Equipment/RV Park Hook-Ups
Accessories. . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75, V1-T6-77
Main Housing
Marina Power and Lighting Equipment/RV Park Hook-Ups
Accessories. . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75–V1-T6-77
Main Lugs
Type BR Loadcenters and Circuit Breakers
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-60
Main Service Modules
Group Metering
Metering Products . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-101
Main Tenant Circuit Breaker
Group Metering
Metering
Products . . . . . . V1-T5-96, V1-T5-98, V1-T5-125, V1-T5-134
Manual Transfer Switches . . . . . . . . . . . . . . . . . . V1-T3-16–V1-T3-19
Emergency Generator Panels . . . . . . . . . . . . . . . . . . . V1-T3-16
Emergency Power Panels . . . . . . . . . . . . . . . . . . . . . . V1-T3-16
Generator Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T3-18
Indoor and Outdoor Designs. . . . . . . . . . . . . . . . . . . V1-T3-17
Indoor and Outdoor Designs . . . . . . . . . . . . . . . . . . . . V1-T3-16
Standard Manual Transfer Switch . . . . . . . . . . . . . . . . V1-T3-18
Switched Neutral Manual Transfer Switch . . . . . . . . . V1-T3-18
Marina Power and Lighting Equipment
Power Pedestals . . . . . . . . . . . . . . V1-T6-2, V1-T6-51–V1-T6-90
Admiral—SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-62
Digital Electronic Kilowatthour Meters . . . . . . . . . . . V1-T6-81
Distribution Equipment—Ground Fault Monitor . . . . V1-T6-82
Distribution Equipment—MegaYacht Powerpoint . . V1-T6-83
Distribution Equipment—Panels . . . . . . . . . . . . . . . . V1-T6-89
Distribution Equipment—Substations. . . . . . . . . . . . V1-T6-86
Distribution Equipment—Transformers . . . . . . . . . . V1-T6-90
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-73

Volume 1—Residential and Light Commercial

CA08100002E—April 2014

www.eaton.com

V1-A3-5

Appendix 3—Alphabetical Product Index
Hatteras Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Lighthouse—SS . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mariner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . .
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

V1-T6-69
V1-T6-54
V1-T6-58
V1-T6-80
V1-T6-65
V1-T6-79

Marina Power and Lighting Equipment/RV Park Hook-Ups
Power Pedestals
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75
Mariner
Marina Power and Lighting Equipment
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-80
Mechanical Interlock Cover
Metering Products
Meter Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-65
Mechanical Interlock Covers
Type BR Loadcenters and Circuit Breakers
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-63
Type CH Loadcenters and Circuit Breakers
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-23
Mechanical Interlocks
Type BR Loadcenters and Circuit Breakers
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-85
Type CH Loadcenters and Circuit Breakers
Accessories . . . . . . . . . . . . . . . . . . . . . . . V1-T1-23, V1-T1-38
Mechanical Lugs
Metering Products . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-34
Metal Covers
StructuredWiringSolutions . . . . . . . . . . . . . . . . . . . . . V1-T4-15
Meter Breakers
Metering Products . . . . . . . . . . . . . . . . . . . V1-T5-37–V1-T5-87
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-77
Aluminum Meter Breakers . . . . . . . . . . . . . . . . . . . . V1-T5-87
CH Style Renovation Solutions. . . . . . . . . . . . . . . . . V1-T5-86
Commercial Safety Sockets . . . . . . . . . . . . . . . . . . . V1-T5-83
EUSERC Requirements Service Entrance Devices . V1-T5-48
House Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-75
Mechanical Interlock Cover . . . . . . . . . . . . . . . . . . . V1-T5-65
Non-EUSERC Combination Service
Entrance Devices. . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-39
Residential Meter Breakers . . . . . . . . . . . . . . . . . . . V1-T5-37
West Coast All-In-One Design . . . . . . . . . . . . . . . . . V1-T5-59
Meter Packs
Group Metering
Metering Products . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-90
Metering Products . . . . . . . . . . . . . . . . . . . . . . . V1-T5-1–V1-T5-147
Commercial Lever Bypass Sockets. . . . . . . V1-T5-10–V1-T5-17
Communications Grounding Device . . . . . . V1-T5-35, V1-T5-36
Cross-Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-31
Group Metering. . . . . . . . . . . . . . . . . . . . . V1-T5-88–V1-T5-147
Accessories . . . . . . . . . . . . V1-T5-136, V1-T5-137, V1-T5-139
Commercial Meter Stack Modules. . . . . . . . . . . . . V1-T5-127
Main Service Modules . . . . . . . . . . . . . . . . . . . . . . V1-T5-101
Main Tenant Circuit
Breaker . . . . . . V1-T5-96, V1-T5-98, V1-T5-125, V1-T5-134
Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-90
Phase Balanced Stack . . . . . . . . . . . . . . . . . . . . . . V1-T5-126
Renewal Parts . . . . . . . . . . . . . . . . . . . V1-T5-138, V1-T5-140

V1-A3-6

Volume 1—Residential and Light Commercial

Residential and Commercial Applications . . . . . . . . . V1-T5-88
Residential Meter Stacks . . . . . . . . . . . . . . . . . . . . V1-T5-116
Surge Metering . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-115
Type CCV Tenant Main Circuit Breaker. . . . . . . . . . . V1-T5-95
Instrument Rated Sockets . . . . . . . . . . . . . . V1-T5-25, V1-T5-26
Mechanical Lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-34
Meter Breakers . . . . . . . . . . . . . . . . . . . . . . V1-T5-37–V1-T5-87
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-77
Aluminum Meter Breakers . . . . . . . . . . . . . . . . . . . . V1-T5-87
CH Style Renovation Solutions . . . . . . . . . . . . . . . . . V1-T5-86
Commercial Safety Sockets . . . . . . . . . . . . . . . . . . . V1-T5-83
EUSERC Requirements Service Entrance Devices. . V1-T5-48
House Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-75
Mechanical Interlock Cover. . . . . . . . . . . . . . . . . . . . V1-T5-65
Non-EUSERC Combination Service
Entrance Devices . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-39
Residential Meter Breakers . . . . . . . . . . . . . . . . . . . V1-T5-37
West Coast All-In-One Design . . . . . . . . . . . . . . . . . V1-T5-59
Meter Socket Accessories
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-30
Multiple Position Horizontal Ganged
Sockets . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-18–V1-T5-24
Residential Pedestals. . . . . . . . . . . . . . . . . . V1-T5-27, V1-T5-28
Single Meter Sockets . . . . . . . . . . . . . . . . . . . V1-T5-2–V1-T5-9
Residential Ringless Type Cover. . . . . . . . . . . . . . . . . V1-T5-4
Mini Digital Cable, Patch Cords
StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-21
Mobile Home Panels
Accessories
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-23
Power Pedestals . . . . . . . . . . . . . . V1-T6-2, V1-T6-21–V1-T6-27
Modulator Modules
StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . . V1-T4-8
Modules
StructuredWiringSolutions
Blank Filler. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Camera with IR Emitters. . . . . . . . . . . . . . . . . . . . . . .
Dome Camera . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DSL or Cable Router . . . . . . . . . . . . . . . . . . . . . . . . . .
Firewall Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Modulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mounting Shelf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mounting Shelf Cover . . . . . . . . . . . . . . . . . . . . . . . . .
Patch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Product Shelf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Service Shelf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Standalone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Video Processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

V1-T4-8
V1-T4-9
V1-T4-9
V1-T4-9
V1-T4-8
V1-T4-8
V1-T4-9
V1-T4-9
V1-T4-8
V1-T4-9
V1-T4-9
V1-T4-8
V1-T4-9

Molded Case Switch
Air Conditioning Disconnects. . . . . . . . . . . . . . V1-T7-2, V1-T7-4
Mounting Bases
Type CH Loadcenters and Circuit Breakers
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-38
Mounting Brackets
Marina Power and Lighting Equipment/RV Park Hook-Ups
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-77

CA08100002E—April 2014

www.eaton.com

Appendix 3—Alphabetical Product Index
Mounting Feet
Marina Power and Lighting Equipment/RV Park Hook-Ups
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-76
Mounting Shelf
StructuredWiringSolutions . . . . . . . . . . . . . . . . . . . . . . V1-T4-9
Mounting Shelf Cover
StructuredWiringSolutions . . . . . . . . . . . . . . . . . . . . . . V1-T4-9
Multiple Position Horizontal Ganged Sockets
Metering Products . . . . . . . . . . . . . . . . . . . V1-T5-18–V1-T5-24

Temporary Power/RV Park
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-7
Pedestal Units
Temporary Power/RV Park
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-16
Phase Adapters
Type CH Loadcenters and Circuit Breakers
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-25

N

Phase Balanced Stack
Group Metering
Metering Products . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-126

Neutral Bar Accessories
Type CH Loadcenters and Circuit Breakers
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-25

Phone, Cable, Internet Assemblies
Marina Power and Lighting Equipment/RV Park Hook-Ups
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-76

Newport Camp Mate Power Pedestal
RV Park Hook-Ups
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-36

Plug-On Circuit Breakers
Type BR
Loadcenters and Circuit Breakers . . . . . . . . . . . . . . . V1-T1-75

Newport Harbor Mate
Marina Power and Lighting Equipment
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-65

Plug-On Neutral Loadcenter
CH Specialty Products
Type CH
Loadcenters and Circuit Breakers . . . . . . . . . . . . . V1-T1-17

Non-EUSERC Combination Service Entrance Devices
Metering Products
Meter Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-39

Plug-On Surge Protection
Surge Protection Devices and Lightning Arrester . . . . . V1-T2-3

Non-Metallic Loadcenter
CH Specialty Products
Type CH
Loadcenters and Circuit Breakers . . . . . . . . . . . . . V1-T1-21

O
Outdoor Communication Grounding Device
Surge Protection Devices and Lightning Arresters . . . . V1-T2-6
Outdoor Speakers
StructuredWiringSolutions . . . . . . . . . . . . . . . . . . . . . V1-T4-10

P
Packaged Products
StructuredWiringSolutions . . . . . . . . . . . . . . . . . . . . . . V1-T4-4
Padmount Adapter
Mobile Home Panels
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-23
Pad-Mount Bracket
Temporary Power/RV Park
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-7
Park Light Power Pedestal
RV Park Hook-Ups
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-39
Patch Cords
StructuredWiringSolutions
Mini Digital Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-21
Telephone. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-21
Patch Modules
StructuredWiringSolutions . . . . . . . . . . . . . . . . . . . . . . V1-T4-8
Pedestal Extension
Mobile Home Panels
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-23

Portable Generators
Residential Standby Backup
Power Solutions . . . . . . . . . . . . . . . . . . . . . V1-T3-7–V1-T3-10
Power Inlet Box
Manual Transfer Switches . . . . . . . . . . . . . . . . . . . . . . V1-T3-18
Power Outlet Panels
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-2
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-1–V1-T6-90
Marina Power and Lighting
Equipment. . . . . . . . . . . . . . . . . . V1-T6-2, V1-T6-51–V1-T6-90
Admiral—SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-62
Digital Electronic Kilowatthour Meters . . . . . . . . . . . V1-T6-81
Distribution Equipment—Ground Fault Monitor . . . . V1-T6-82
Distribution Equipment—MegaYacht Powerpoint . . V1-T6-83
Distribution Equipment—Panels . . . . . . . . . . . . . . . . V1-T6-89
Distribution Equipment—Substations. . . . . . . . . . . . V1-T6-86
Distribution Equipment—Transformers . . . . . . . . . . V1-T6-90
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-73
Hatteras Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-69
Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-54
Lighthouse—SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-58
Mariner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-80
Newport Harbor Mate. . . . . . . . . . . . . . . . . . . . . . . . V1-T6-65
Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-79
Marina Power and Lighting Equipment/RV Park Hook-Ups
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75
Mobile Home Panels . . . . . . . . . . . V1-T6-2, V1-T6-21–V1-T6-27
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-23
Power Outlet Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-2
RV Park Hook-Ups . . . . . . . . . . . . . . . . . . . . V1-T6-28–V1-T6-50
Digital Electronic Kilowatthour Meters . . . . . . . . . . . V1-T6-44
Distribution Equipment—Panels . . . . . . . . . . . . . . . . V1-T6-49
Distribution—Ground Fault Monitor . . . . . . . . . . . . . V1-T6-45
Distribution—Substations . . . . . . . . . . . . . . . . . . . . . V1-T6-46
Distribution—Transformers. . . . . . . . . . . . . . . . . . . . V1-T6-50

Volume 1—Residential and Light Commercial

CA08100002E—April 2014

www.eaton.com

V1-A3-7

Appendix 3—Alphabetical Product Index
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-42
Newport Camp Mate Power Pedestal . . . . . . . . . . . V1-T6-36
Park Light Power Pedestal . . . . . . . . . . . . . . . . . . . . V1-T6-39
Powerhouse Power Pedestal . . . . . . . . . . . . . . . . . . V1-T6-30
Powerhouse Stainless Steel Power Pedestal. . . . . . V1-T6-33
Temporary Power/RV Park . . . . . . . . . . . . . . V1-T6-3–V1-T6-20
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-7
Pedestal Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-16
Surface Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-10
Powerhouse Power Pedestal
RV Park Hook-Ups
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-30
Powerhouse Stainless Steel Power Pedestal
RV Park Hook-Ups
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-33
Product Shelf
StructuredWiringSolutions . . . . . . . . . . . . . . . . . . . . . . V1-T4-9
Pullouts, Fused and Non-Fused
Air Conditioning Disconnects . . . . . . . . . . . . . V1-T7-2, V1-T7-4

Metering Products . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-116
Residential Pedestals
Metering Products . . . . . . . . . . . . . . . . . . . . V1-T5-27, V1-T5-28
Residential Ringless Type Cover
Single Meter Sockets
Metering Products . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-4
Residential Standby Backup Power Solutions . . . . V1-T3-1–V1-T3-15
Automatic Transfer Switches . . . . . . . . . . . V1-T3-11–V1-T3-15
Manual Transfer Switches . . . . . . . . . . . . . . V1-T3-16–V1-T3-19
Portable Generators. . . . . . . . . . . . . . . . . . . . V1-T3-7–V1-T3-10
Standby Generator. . . . . . . . . . . . . . . . . . . . . . V1-T3-2–V1-T3-6
RG6 Inserts
StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-20
Riser Panel
BR Specialty Products
Type BR
Loadcenters and Circuit Breakers . . . . . . . . . . . . . V1-T1-58
RJ11 Inserts
StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-20
RJ45, CAT5e Inserts
StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-20

Q
Quick Connect Design
Surge Protection Devices and Lightning Arresters . . . . V1-T2-6
Quick-Pro
Type BR
Loadcenters and Circuit Breakers . . . . . . . . . . . . . . V1-T1-59

R
Rainproof Conduit Hub
Temporary Power/RV Park
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-7
Rainproof Conduit Hubs
Type BR Loadcenters and Circuit Breakers
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-65
Type CH Loadcenters and Circuit Breakers
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-25
Raintight Enclosure
Surge Protection Devices and Lightning Arresters . . . . V1-T2-6
Receptacles
Marina Power and Lighting Equipment/RV Park Hook-Ups
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75
Remote Controls, A-BUS Products
StructuredWiringSolutions . . . . . . . . . . . . . . . . . . . . . V1-T4-12
Renewal Parts
Group Metering
Metering Products . . . . . . . . . . . . . . . . V1-T5-138, V1-T5-140
Temporary Power/RV Park
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-8

Rough-In Ring
StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-10
Round Ceiling Speakers
StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-10
RV Park Hook-Ups
Power Pedestals . . . . . . . . . . . . . . . . . . . . . V1-T6-28–V1-T6-50
Digital Electronic Kilowatthour Meters . . . . . . . . . . . V1-T6-44
Distribution Equipment—Panels . . . . . . . . . . . . . . . . V1-T6-49
Distribution—Ground Fault Monitor . . . . . . . . . . . . . V1-T6-45
Distribution—Substations . . . . . . . . . . . . . . . . . . . . . V1-T6-46
Distribution—Transformers. . . . . . . . . . . . . . . . . . . . V1-T6-50
Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-42
Newport Camp Mate Power Pedestal . . . . . . . . . . . V1-T6-36
Park Light Power Pedestal . . . . . . . . . . . . . . . . . . . . V1-T6-39
Powerhouse Power Pedestal . . . . . . . . . . . . . . . . . . V1-T6-30
Powerhouse Stainless Steel Power Pedestal . . . . . . V1-T6-33

S
Safety Sockets, Commercial
Meter Breakers
Metering Products . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-83
Service Entrance Surge Protection
Surge Protection Devices and Lightning Arresters . . . . V1-T2-2
Service Shelf
StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . . V1-T4-9

Residential and Commercial Applications
Group Metering
Metering Products . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-88

Shunt Trip
Type BR Loadcenters and Circuit Breakers
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-85
Type CH Loadcenters and Circuit Breakers
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-39

Residential Meter Breakers
Meter Breakers
Metering Products . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-37

Single Meter Sockets
Metering Products . . . . . . . . . . . . . . . . . . . . . . V1-T5-2–V1-T5-9
Residential Ringless Type Cover. . . . . . . . . . . . . . . . . V1-T5-4

Residential Meter Stacks
Group Metering

Single-Phase
Type BR

V1-A3-8

Volume 1—Residential and Light Commercial

CA08100002E—April 2014

www.eaton.com

Appendix 3—Alphabetical Product Index
Loadcenters and Circuit Breakers . . . . . . . . . . . . . . V1-T1-48
Type CH
Loadcenters and Circuit Breakers . . . . . . . . . . . . . . . V1-T1-7
Smart Start
Marina Power and Lighting Equipment
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-79
Spa Panels
BR Specialty Products
Type BR
Loadcenters and Circuit Breakers . . . . . . . . . . . . . V1-T1-57
CH Specialty Products
Type CH
Loadcenters and Circuit Breakers . . . . . . . . . . . . . V1-T1-14
Type BR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-57
Spring Closure
Marina Power and Lighting Equipment/RV Park Hook-Ups
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75
Standalone Modules
StructuredWiringSolutions . . . . . . . . . . . . . . . . . . . . . . V1-T4-8
Standard Manual Transfer Switch
Manual Transfer Switches . . . . . . . . . . . . . . . . . . . . . V1-T3-18
Standby Generator . . . . . . . . . . . . . . . . . . . . . . . . . V1-T3-2–V1-T3-6
Air Cooled Generators. . . . . . . . . . . . . . . . . . . . . . . . . . V1-T3-3
Liquid Cooled Generators . . . . . . . . . . . . . . . . . . . . . . . V1-T3-4
Standby Generator System
Air Cooled Standby . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T3-2
Liquid Cooled Standby . . . . . . . . . . . . . . . . . . . . . . . . . V1-T3-2
Strobe Light
Marina Power and Lighting Equipment/RV Park Hook-Ups
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-77
Structured Wiring . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-1–V1-T4-22
StructuredWiringSolutions . . . . . . . . . . . . . . . . . . V1-T4-2–V1-T4-22
A-BUS Products . . . . . . . . . . . . . . . . . . . . . V1-T4-11–V1-T4-13
Audio System Components . . . . . . . . . . . . . . . . . . . . V1-T4-10
Combination Modules . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-7
Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-15–V1-T4-17
Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-14, V1-T4-15
Inserts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-20
Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-8, V1-T4-9
Packaged Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-4
Patch Cords. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-21
Telephone Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-6
Video Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-5
Wall Plates . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-18, V1-T4-19
Surface Units
Temporary Power/RV Park
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-10
Surge Installed Loadcenters
Surge Protection Devices and Lightning Arrester . . . . . V1-T2-7
Surge Metering
Group Metering
Metering Products . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-115
Surge Panel
CH Specialty Products
Type CH
Loadcenters and Circuit Breakers . . . . . . . . . . . . . V1-T1-15

Surge Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T2-1–V1-T2-8
Factory-Installed Surge Protection. . . . . . . . . . V1-T2-2, V1-T2-7
Plug-On Surge Protection . . . . . . . . . . . . . . . . . . . . . . . V1-T2-3
Type 3 Point-of-Use Surge Protection. . . . . . . . . . . . . V1-T2-3
Type BRSURGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T2-3
Type BRSURGECSA . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T2-3
Type CHQSA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T2-3
Type CHSA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T2-3
Service Entrance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T2-2
Surge Installed Loadcenters . . . . . . . . . . . . . . . . . . . . . V1-T2-7
Surge Protection Devices and
Lightning Arresters . . . . . . . . . . . . . . . . . . . . V1-T2-2–V1-T2-8
Surge Ready Loadcenter . . . . . . . . . . . . . . . . . V1-T2-2, V1-T2-7
Two-Stage Protection . . . . . . . . . . . . . . . . . . . V1-T2-2, V1-T2-3
UL 1449 3rd Edition Surge Protection
Type 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T2-2
Type 1 CHSP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T2-4
Type 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T2-2
Type 2 Plug-On . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T2-8
UL 1449 3rd Edition, cUL
Type 2 CHSP Service Entrance. . . . . . . . . . . . . . . . . . V1-T2-5
Surge Protection Devices and
Lightning Arresters . . . . . . . . . . . . . . . . . . . . . . . . V1-T2-2–V1-T2-8
Surge Ready
Type CH
Loadcenters and Circuit Breakers . . . . . . . . . . . . . . . V1-T1-16
Surge Ready Loadcenter . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T2-7
Surge Protection Devices and Lightning Arresters . . . . V1-T2-2
Switched Neutral Manual Transfer Switch
Manual Transfer Switches . . . . . . . . . . . . . . . . . . . . . . V1-T3-18

T
Telephone Modules
StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . . V1-T4-6
Telephone Patch Cords
StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-21
Temporary Power/RV Park
Power Pedestals . . . . . . . . . . . . . . . . . . . . . . V1-T6-3–V1-T6-20
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-7
Pedestal Units. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-16
Surface Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-10
Three-Phase
Type BR
Loadcenters and Circuit Breakers . . . . . . . . . . . . . . . V1-T1-54
Type CH
Loadcenters and Circuit Breakers . . . . . . . . . . . . . . . V1-T1-12
Transfer Panels
Manual Transfer Switches . . . . . . . . . . . . . . . . . . . . . . V1-T3-16
Two-Stage Protection
Surge Protection Devices and
Lightning Arresters . . . . . . . . . . . . . . . . . . . . V1-T2-2, V1-T2-3
Type 1 Surge Protective Device
Surge Protection Devices and Lightning Arresters . . . . V1-T2-2
Type 2 Surge Protective Device
Surge Protection Devices and Lightning Arresters . . . . V1-T2-2
Type 3 Point-of-Use Surge Protection
Surge Protection Devices and Lightning Arresters . . . . V1-T2-3

Volume 1—Residential and Light Commercial

CA08100002E—April 2014

www.eaton.com

V1-A3-9

Appendix 3—Alphabetical Product Index
Type BR
Loadcenters and Circuit Breakers . . . . . . . . V1-T1-42–V1-T1-69
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-60
BR Specialty Products
BR Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-75
Riser Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-58
Spa Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-57
Type BR Renovation Loadcenter . . . . . . . . . . . . . . V1-T1-59
Type BR Retrofit Interior Kits. . . . . . . . . . . . . . . . . V1-T1-72
Common Trip Quadplex Breakers . . . . . . . . . . . . . . V1-T1-82
Convertible Loadcenters MCB . . . . . . . . . . . . . . . . . V1-T1-51
Convertible Loadcenters MLO . . . . . . . . . . . . . . . . . V1-T1-51
Plug-On Circuit Breakers . . . . . . . . . . . . . . . . . . . . . V1-T1-75
Quick-Pro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-59
Single-Phase. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-48
Spa Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-57
Three-Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-54

U
UL 1449 3rd Edition
Surge Protection Devices and Lightning Arrester . . . . . V1-T2-2

V
Video Amplifier Power Supply, 110 Volt
StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . . V1-T4-5
Video Modules
StructuredWiringSolutions
Coax Module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-5
Video Amplifier Power Supply, 110 Volt . . . . . . . . . . . V1-T4-5
Video Processor
StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . . V1-T4-9
Volume Control
StructuredWiringSolutions. . . . . . . . . . . . . . V1-T4-10, V1-T4-11

Type BR Renovation Loadcenter
BR Specialty Products
Type BR
Loadcenters and Circuit Breakers . . . . . . . . . . . . . V1-T1-59

W

Type BR Retrofit Interior Kits
BR Specialty Products
Type BR
Loadcenters and Circuit Breakers . . . . . . . . . . . . . V1-T1-72

Wall Outlet Plates
StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-18

Type BRSURGE Surge Protection
Surge Protection Devices and Lightning Arresters . . . . V1-T2-3
Type CCV Tenant Main Circuit Breaker
Group Metering
Metering Products . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-95
Type CH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-16
Loadcenters and Circuit Breakers . . . . . . . . . V1-T1-2–V1-T1-28
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-22
CH Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-31
CH Specialty Products
Non-Metallic Loadcenter . . . . . . . . . . . . . . . . . . . . V1-T1-21
Plug-On Neutral Loadcenter . . . . . . . . . . . . . . . . . V1-T1-17
Spa Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-14
Surge Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-15
Type CH Renovation Loadcenter . . . . . . . . . . . . . . V1-T1-18
Circuit Breaker Unit Enclosures . . . . . . . . . . . . . . . . V1-T1-94
Convertible Loadcenters MCB . . . . . . . . . . . . . . . . . V1-T1-11
Convertible Loadcenters MLO . . . . . . . . . . . . . . . . . V1-T1-11
Single-Phase. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-7
Surge Ready . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-16
Three-Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-12

Wall Hanging Outlet Plates
StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-18

Wall Plates
StructuredWiringSolutions
Blank Oversized Plate . . . . . . . . . . . . . . . . . . . . . . . .
Blank Receptacle . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wall Hanging Outlet . . . . . . . . . . . . . . . . . . . . . . . . .
Wall Outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Water Assemblies
Marina Power and Lighting Equipment/RV Park Hook-Ups
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-76
West Coast All-In-One Design
Meter Breakers
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-60
Metering Products . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-59

Numerics
3-Pack
Surge Protection Devices and Lightning Arresters . . . . V1-T2-6

Type CH Renovation Loadcenter
CH Specialty Products
Type CH
Loadcenters and Circuit Breakers . . . . . . . . . . . . . V1-T1-18
Type CH Retrofit Interior Kits
CH Specialty Products
Type CH
Loadcenters and Circuit Breakers . . . . . . . . . . . . . V1-T1-19
Type CHQSA Surge Protection
Surge Protection Devices and Lightning Arresters . . . . V1-T2-3
Type CHSA Surge Protection
Surge Protection Devices and Lightning Arresters . . . . V1-T2-3

V1-A3-10

V1-T4-19
V1-T4-19
V1-T4-18
V1-T4-18

Volume 1—Residential and Light Commercial CA08100002E—April 2014

www.eaton.com



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : Eaton Corporation
Create Date                     : 2011:07:24 09:29:06-04:00
Modify Date                     : 2014:06:25 07:41:21-04:00
Subject                         : CA08100002E
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Metadata Date                   : 2014:06:25 07:41:21-04:00
Creator Tool                    : Adobe InDesign CS4 (6.0)
Format                          : application/pdf
Title                           : Volume 01—Residential and Light Commercial
Creator                         : Eaton Corporation
Description                     : CA08100002E
Document ID                     : uuid:d5c50c0d-4aa2-4977-b12a-f8e4e521b5cd
Instance ID                     : uuid:b2a543a4-d0f6-43c8-9e0e-073a03cbf330
Producer                        : Adobe PDF Library 9.0
Page Layout                     : SinglePage
Page Count                      : 419
EXIF Metadata provided by EXIF.tools

Navigation menu