Volume 01—Residential And Light Commercial
101954-Attachment 101954-Attachment 101954-Attachment 786685 Batch5 unilog cesco-content
24837-Catalog 24837-Catalog 24837-Catalog 786685 Batch5 unilog cesco-content
24837-Catalog 24837-Catalog 24837-Catalog 786676 Batch5 unilog cesco-content
101954-Attachment 101954-Attachment 101954-Attachment 786849 Batch5 unilog cesco-content
24837-Catalog 24837-Catalog 24837-Catalog 786849 Batch5 unilog cesco-content
2014-07-05
: Pdf 101954-Attachment 101954-Attachment 782116 Batch5 unilog
Open the PDF directly: View PDF .
Page Count: 419
Download | |
Open PDF In Browser | View PDF |
Electrical Sector Solutions Volume 1 Residential and Light Commercial Eaton Corporation Electrical Sector 1111 Superior Ave. Cleveland, OH 44114 United States 877-ETN-CARE (877-386-2273) Eaton.com © 2010 Eaton Corporation All other trademarks are property of their respective owners. All Rights Reserved Printed in USA Publication No. CA08100002E / MSC December 2010 Volume 1: Residential and Light Commercial Volume 1—Residential and Light Commercial Tab 1—Loadcenters and Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . V1-T1-1 Tab 2—Surge Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T2-1 Tab 3—Residential Standby Backup Power Solutions . . . . . . . . . . . . V1-T3-1 Tab 4—Structured Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-1 Tab 5—Metering Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-1 Tab 6—Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-1 Tab 7—Air Conditioning Disconnects . . . . . . . . . . . . . . . . . . . . . . . . . V1-T7-1 Appendix 1—Eaton Terms & Conditions . . . . . . . . . . . . . . . . . . . . . . . V1-A1-1 Appendix 2—Catalog Parent Number Index . . . . . . . . . . . . . . . . . . . . V1-A2-1 Appendix 3—Alphabetical Product Index . . . . . . . . . . . . . . . . . . . . . . V1-A3-1 1 Copyright Dimensions, Weights and Ratings Dimensions, weights and ratings given in this catalog are approximate and should not be used for construction purposes. Drawings containing exact dimensions are available upon request. All listed product specifications and ratings are subject to change without notice. Photographs are representative of production units. Terms and Conditions All prices and discounts are subject to change without notice. When price changes occur, they are published in Eaton’s Price and Availability Digest (PAD). All orders accepted by Eaton’s Electrical Sector are subject to the general terms and conditions as set forth in Appendix 1—Eaton Terms & Conditions. Technical and Descriptive Publications This catalog contains brief technical data for proper selection of products. Further information is available in the form of technical information publications and illustrated brochures. If additional product information is required, contact your local Eaton Products Distributor, call 1-800-525-2000 or visit our website at www.eaton.com. Compliance with Nuclear Regulation 10 CFR 21 Eaton products are sold as commercial grade products not intended for application in facilities or activities licensed by the United States Nuclear Regulatory Commission for atomic purposes, under 10 CFR 21. Further certification will be required for use of these products in a safety-related application in any nuclear facility licensed by the U.S. Nuclear Regulatory Commission. WARNING The installation and use of Eaton products should be in accordance with the provisions of the U.S. National Electrical Code® and/or other local codes or industry standards that are pertinent to the particular end use. Installation or use not in accordance with these codes and standards could be hazardous to personnel and/or equipment. These catalog pages do not purport to cover all details or variations in equipment, nor to provide for every possible contingency to be met in connection with installation, operation or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s purposes, the matter should be referred to the local Eaton Products Distributor or Sales Office. The contents of this catalog shall not become part of or modify any prior or existing agreement, commitment or relationship. The sales contract contains the entire obligation of Eaton’s Electrical Sector. The warranty contained in the contract between the parties is the sole warranty of Eaton. Any statements contained herein do not create new warranties or modify the existing warranty. Copyright ©2014 Eaton, All Rights Reserved. Introduction Eaton is a global leader in power distribution, power quality, control and automation, and monitoring products. At Eaton, we believe a reliable, efficient and safe power system is the foundation of every successful enterprise. Through innovative technologies, cutting-edge products and our highly skilled services team, we empower businesses around the world to achieve a powerful advantage. In addition, Eaton is committed to creating and maintaining powerful customer relationships built on a foundation of excellence. From the products we manufacture to our dedicated customer service and support, we know what’s important to you. Solutions Eaton takes the complexity out of power systems management with a holistic and strategic approach, leveraging our industry-leading technology, solutions and services. We focus on the following three areas in all we do: ● Reliability—maintain the appropriate level of power continuity without disruption or unexpected downtime ● Efficiency—minimize energy usage, operating costs, equipment footprint and environmental impact ● Safety—identify and mitigate electrical hazards to protect what you value most Using the Eaton Catalog Library As we grow, it becomes increasingly difficult to include all products in one or two comprehensive catalogs. Knowing that each user has their specific needs, we have created a library of catalogs for our products that when complete, will contain 15 volumes. Since the volumes will continuously be a work in progress and updated, each volume will stand alone. Refer to our volume directory, MZ08100001E, for a quick glance of where to look for the products you need. The 15 volumes include: ● ● ● ● ● ● Volume 1—Residential and Light Commercial (CA08100002E) Volume 2—Commercial Distribution (CA08100003E) Volume 3—Power Distribution and Control Assemblies (CA08100004E) Volume 4—Circuit Protection (CA08100005E) Volume 5—Motor Control and Protection (CA08100006E) Volume 6—Solid-State Motor Control (CA08100007E) ● ● ● ● ● Volume 7—Logic Control, Operator Interface and Connectivity Solutions (CA08100008E) Volume 8—Sensing Solutions (CA08100010E) Volume 9—Original Equipment Manufacturer (CA08100011E) Volume 10—Enclosed Control (CA08100012E) Volume 11—Vehicle and Commercial Controls (CA08100013E) ● ● ● ● Volume 12—Aftermarket, Renewal Parts and Life Extension Solutions (CA08100014E) Volume 13—Counters, Timers and Tachometers (CA08100015E)—Available in electronic format only Volume 14—Fuses (CA08100016E)—Available in electronic format only Volume 15—Solar Inverters and Electrical Balance of System (CA08100018E) These volumes are not all-inclusive of every product, but they are meant to be an overview of our product lines. For our full range of product solutions and additional product information, consult Eaton.com/electrical and other catalogs and product guides in our literature library. These references include: ● The Consulting Application Guide (CA08104001E) ● The Eaton Power Quality Product Guide (COR01FYA) If you don’t have the volume that contains the product or information that you are looking for, not to worry. You can access every volume of the catalog library at Eaton.com/electrical in the Literature Library. By installing our Automatic Tab Updater (ATU), you can be sure you always have the most recent version of each volume and tab. Volume 1—Residential and Light Commercial CA08100002E—April 2014 www.eaton.com i Introduction Icons Green Leaf Eaton Green Solutions are products, systems or solutions that represent Eaton benchmarks for environmental performance. The green leaf symbol is our promise that the solution has been reviewed and documented as offering exceptional, industry-leading environmental benefits to customers, consumers and our communities. Though all of Eaton’s products and solutions are designed to meet or exceed applicable government standards related to protecting the environment, our products with the Green Leaf designation further provide “exceptional environmental benefit.” Learn Online When you see the Learn Online icon, go to Eaton.com/electrical and search for the product or training page. There you will find 100-level training courses, podcasts, webcasts or games and puzzles to learn more. Drawings Online When you see the Drawings Online icon, go to Eaton.com/electrical and find the products page. There you will find a tab that includes helpful product drawings and illustrations. Contact Us If you need additional help, you can find contact information under the Customer Care heading of Eaton.com/electrical. ii Volume 1—Residential and Light Commercial CA08100002E—April 2014 www.eaton.com Loadcenters and Circuit Breakers Residential Loadcenters and Breaker Family 1.1 Type CH Loadcenters and Circuit Breakers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Single-Phase. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Three-Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CH Specialty Products. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Spa Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Surge Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Plug-On Neutral Loadcenter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type CH Renovation Loadcenter . . . . . . . . . . . . . . . . . . . . . . . . . . Type CH Retrofit Interior Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Non-Metallic Loadcenter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CH Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2 V1-T1-14 V1-T1-15 V1-T1-17 V1-T1-18 V1-T1-19 V1-T1-21 V1-T1-31 V1-T1-42 V1-T1-48 V1-T1-54 V1-T1-57 V1-T1-57 V1-T1-58 V1-T1-59 V1-T1-72 V1-T1-75 V1-T1-88 V1-T1-89 V1-T1-89 V1-T1-93 V1-T1-94 Classified Circuit Breakers Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Enclosed Breakers Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.5 V1-T1-14 Loadcenter Interiors/OEM Loadcenters Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Standards and Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.4 V1-T1-7 V1-T1-12 Type BR Loadcenters and Circuit Breakers Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Single-Phase. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Three-Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BR Specialty Products. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Spa Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Riser Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type BR Renovation Loadcenter. . . . . . . . . . . . . . . . . . . . . . . . . . . Type BR Retrofit Interior Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BR Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.3 V1-T1-2 V1-T1-96 V1-T1-97 V1-T1-99 V1-T1-99 V1-T1-100 1 1 1 1 1 1 1 Learn Online 1 1 1 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-1 1.1 1 Loadcenters and Circuit Breakers Type CH Loadcenters and Circuit Breakers Eaton Type CH Convertible Family Contents Description 1 Overview Product Description . . . . . . . . . . . . . . . . . . . . . Features, Benefits and Functions . . . . . . . . . . Standards and Certifications . . . . . . . . . . . . . . Catalog Number Selection . . . . . . . . . . . . . . . . Product Selection. . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . CH Specialty Products . . . . . . . . . . . . . . . . . . . . . CH Loadcenter Options and Accessories . . . . . . . CH Circuit Breakers. . . . . . . . . . . . . . . . . . . . . . . . 1 1 1 1 1 Page V1-T1-3 V1-T1-3 V1-T1-4 V1-T1-6 V1-T1-7 V1-T1-29 V1-T1-14 V1-T1-22 V1-T1-31 1 1 1 1 Overview 1 Product Selection Guide 1 CH Loadcenters 1 Description 1 Single-phase, three-wire, 120/240 Vac Three-phase, three-wire, 240V corner grounded delta 1 Short-Circuit Current Rating 1 1 1 1 Service 10 kAIC: All single- and three-phase loadcenters 40–400A, 2–42 circuits except when series ratings are applied 25 kAIC: All factory-installed main breakers single-phase loadcenters rated 150–225A using Type CSR main breakers Single-phase Main breaker: 100, 125, 150, 200, 225, 400A Main lugs: 40, 70, 125, 150, 200, 225, 400A 1 Type CH: 10–150A. Single-, two- and three-pole. Selected amperages available in shunt trip, HACR and switching duty Ground fault circuit interruptors: 15–60A Type CH-HID: 15–30A. Single-, two- and three-pole CH-HM high magnetic CH-M50 high ambient Branch Breakers 1 Enclosures 1 Loadcenter and Breaker Accessories 1 1 1 1 Three-phase Main breaker: 150, 200, 225, 300, 400A Main lugs: 125, 150, 200, 225, 400A Convertible Loadcenters Main breaker or main lugs: single-phase up to 225A 1 35 kAIC available on convertible units using CSH main breaker 42 and 100 kAIC are available on some styles: single-phase and three-phase Main Breaker/Main Lug Loadcenters 1 1 Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta NEMA® Type 1 indoor Type CH-AFCI arc fault circuit interrupter Type CHP: 10–125A. Single-, two- and three-pole. three-position commercial trip Selected amperages available in HACR switching duty Type CHP-HID: 15–30A. Single-, two- and three-pole Type CHP-GFCI: 15–30A. Single-pole ground fault breakers NEMA Type 3R outdoor. Branch circuit breaker: Auxiliary components Hold-down kits Handle ties Lockoffs Lockdogs Complete line of ground bar kits 5, 10, 14 and 21 circuits, some with additional #2/0 lugs Each terminal will accommodate: (3) #14–#10 Cu/Al or (1) #14–#4 Cu/Al Sub-feed lugs 125, 150A—two- and three-pole Shunt trips Universal rainproof conduit hubs Group One: 3/4, 1, 1-1/4, 1-1/2, 2 inches (19.1, 25.4, 31.8, 38.1, 50.8 mm) Group Two: 2, 2-1/2, 3 inches (50.8, 63.5, 76.2 mm) Adapter plate Bussing Silver flash plated copper bus is a standard feature V1-T1-2 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com Loadcenters and Circuit Breakers Type CH Loadcenters and Circuit Breakers Product Description Features, Benefits and Functions Loadcenters are enclosures specifically designed to house the branch circuit breakers and wiring required to distribute power to individual circuits. They contain either a main breaker when used at the service entrance point or a main lug when used as a sub-panel to add circuits to existing service. The main breaker protects the main entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets. Loadcenter Construction Eaton’s Type CH loadcenters feature silver flash plated copper bus in all interiors. Stabs are rated 200A throughout the CH line. Therefore, the sum of the handle ratings connected to any one stab is limited to 200A maximum. NEMA 1 boxes are manufactured from cold rolled 16 gauge sheet steel. Raintight boxes are manufactured from galvanized steel. All boxes and trims are finished using an electrostatic powder coat, baked urethane paint process. Neutrals Eaton Type CH loadcenters feature two types of neutrals: Insulated/Bondable Split Neutral Panels are supplied with split insulated neutrals with an insulated cross strap. For service entrance applications, the neutral must be bonded by using the bonding strap supplied with the panel. For non-service entrance (subpanel) applications, the panel may be installed with the bonding strap not connected to the neutral. Separate ground bars must be used on non-service entrance panels. 1.1 1 Insulated/Bondable Single Neutral Panels are supplied with a single insulated neutral. For service entrance applications, all that is required to bond the neutral is to loosen the bonding screw and the neutral screw directly beside it, insert the bonding strap into the neutral bar, and retighten both connections. The single neutral can be moved by the contractor to the other side of the panel, if desired. When used as a service entrance panel, unused neutral connections may be used for the termination of equipment grounds. For nonservice entrance (sub-panel) applications, the panel may be installed with the bonding strap not connected to the neutral. Separate ground bars must be used on non-service entrance panels. Inboard Plug-On Neutral Code changes and higher safety standards are leading to more arc fault circuit interrupter (AFCI) installations. With the electrical contractor in mind, Eaton has revolutionized the way Combination AFCIs are installed with the Plug-on Neutral line of loadcenters and breakers. This unique product solution enables the contractor to connect the breaker directly to the neutral bar, eliminating the need for wiring a pigtail. Grounds In service entrance applications where the neutral is bonded, unused neutral holes may be used for terminating ground conductors. In sub-feed panels, the neutral must be isolated (non-bonded), and ground wires must be terminated on a separate ground bar. The insulated/bondable single/split neutral panels have sufficient terminations for both ground and neutral conductors. The insulated/ bondable single split neutral panels are supplied with a separate factory-installed ground bar if the catalog number contains a “G.” If not, a separate ground bar should be installed. Insulated/ Bondable Single Neutral panels are supplied without a ground bar (unless otherwise noted), and ground bar kits, if needed, must be purchased separately. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-3 1.1 Loadcenters and Circuit Breakers Type CH Loadcenters and Circuit Breakers 1 Standards and Certifications 1 UL® Listings All Eaton Type CH loadcenters are listed under UL File E8741. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Neutral and Ground Terminals The standard terminals on grounds and neutrals are rated to accept (3)—#14–#10 Cu/Al or (1)—#14–4 wires. For larger cables, add-on neutral lugs may be ordered from the Accessories. Note: NEC® allows only one current carrying conductor per hole on neutrals unless otherwise noted. Bottom-Fed Loadcenters When the power cable is brought into the loadcenter from below the panel; then the main lug panels, and single-phase, 225A and below, loadcenters can be rotated 180 degrees to allow straight-in wiring of power cables to the main terminals. Because the CSR main circuit breaker handle operates horizontally, the orientation of the main circuit breaker handle is consistent with the requirements of NEC Article 240.81. Gutter Splicing Loadcenters are not UL listed as wiring troughs. Therefore, gutter splicing of riser cables to tap off to the main device is not permitted. Refer to NEC Article 373.8. 1 1 1 1 1 1 1 Fire Rating Due to the numerous openings in both loadcenter boxes and trims, they should not be mounted in firewalls. There is no approval method for sealing the enclosures for this application. Date Code The date of manufacture of each loadcenter is printed on the outside of the carton as well as inside the loadcenter. On the carton, the date code is printed on the end carton label. In the loadcenter, the date code is located on the small white label located on the right side wall (with the main device on top). The date code is in the following format: F # # # &. The “F” is the numeric code for the Lincoln, IL plant, and the three numbers are the year and week of manufacture, e.g., 023. The “&” sign at the end signifies the decade of the 2000s. The “!” at the end signifies the decade of the 2010s. Therefore, the date code F023& would indicate that the product was manufactured in the 23rd week of 2000. The 1980s are represented by a “+” sign and the 1990s are represented by a “=” at the end of the code. Plug-On Type CH Breakers Quick-make, quick-break switch mechanism combined with inverse time element tripping operation and tripfree handle design. Type CH circuit breakers trip to the OFF position eliminating nuisance callbacks. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. CHF breakers include a ‘trip flag’ to differentiate between a tripped breaker and one that has been turned off. Multipole breakers have internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker. Type CH breakers meet UL Standard 489, NEMA standards, and Federal Spec Classification W-C 375 b/Gen. They are UL listed under File Number E11713, E8741, E3624 and E51287: and CSA® certified file number LR87196, except Type CHT breakers. Type CH Circuit Breaker Ratings Single- and double-pole CH breakers rated 15 and 20A have low instantaneous magnetic trip levels. The 15 and 20A breakers with “HM” suffix have high magnetic trip settings recommended for circuits with inherently high inrush currents. All Type CH breakers are marked for heating, air conditioning and refrigeration (HACR) equipment application. Single-pole 15–20A breakers are also suitable for switching duty (SWD). Shunt trip coils operate on 120 Vac and require one additional pole space per breaker. 1 1 1 V1-T1-4 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com Loadcenters and Circuit Breakers Type CH Loadcenters and Circuit Breakers 1.1 Type CH Loadcenter 1 Extra 1.5 inch Knockout (38.1 mm) ■ Larger knockout provides easier installation and time savings for renovation installations Top or Bottom Feed Straight-in wiring saves labor and material “Tangential” Center Knockout ■ Easier installation for conduit applications 1 Unique Sandalwood Finish ■ Aesthetically appealing, scratch-resistant powder coating 1 1 ■ ■ 1 Neutral Bus (Strap) One panel for either top or bottom applications ■ 1 Easily removable for sub-panel applications 1 2/0 Lug Easily removable and can be installed in any location on the neutral bar ■ 1 Bonding Z-Strap ■ Provides easy field conversion for service entrance applications Commercial Grade Main Breaker ■ 25 kAIC series rated main breaker in 150A–225A loadcenters. 35, 42 and 100 kAIC series ratings are available ■ 1 1 Twin Neutral Bars ■ Minimum 150% neutral capacity 1 Type CHF AFCI/GFCI/Thermal Magnetic Breakers ■ Advanced electronics effectively reduce nuisance tripping Optional convertible design— reduces inventory requirements One Piece Silver-Flashed Copper Bus ■ Provides superior conductivity, corrosion resistance and durability Drywall Marking on Enclosure Indicates proper mounting depth for flush applications ■ ■ CHF AFCI breakers have a standard diagnostic LED indicating 1 of 7 trip codes ■ Mechanical flag for trip indication (on thermal-magnetic AFCI and GFCI) ■ All CH breakers provide industry exclusive 2-position handle with simple 1 step reset ● Lifetime loadcenter warranty Lifetime warranty on CH circuit breakers 1 1 1 1 1 1 1 Steel Backpan Provides solid and reliable breaker mounting—single piece design for stability and durability ● 1 1 ■ Warranty The minimum warranty for residential loadcenters, breakers and surge protection devices shall be as follows: 1 1 Single Keyhole Mounting ■ One keyhole at the top and bottom provides easier mounting and leveling 1 1 1 ● ● 1 Lifetime warranty on CHSPT2ULTRA including $75,000 connected equipment warranty 1-year warranty on plug-in surge protective device (CHSA) 1 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-5 1.1 Loadcenters and Circuit Breakers Type CH Loadcenters and Circuit Breakers 1 Catalog Number Selection 1 Loadcenters 100–225A and 12–42 Circuits CH 42 B 1 1 LC Type Type CH 3/4-inch (19.1 mm) branch circuit breakers 1 Number of Circuits Selection circuits 2 20 4 22 8 24 12 28 14 30 16 32 18 42 1 1 1 1 L B N H 200 K Construction Blank = Standard PN = Plug-on neutral Phases Blank = Single-phase 3 = Three-phase 1 1 Accessories Blank = Standard EC = Surge ready SUR = Surge factory installed Indoor Covers Ordered Separately 1 CH 1 8 K F Type CH 1 Factory Options Blank = Standard SUR = Surge/surge ready 1 Loadcenter Cover Series Mounting F = Combination flush/surface S = Surface Accessories Blank = Standard M = Mechanical interlock Box Size Indicated in loadcenter catalog number 1 1 Box Sizes B C D E G J K L R = Outdoor (no cover) Bus Amperes 40 150 70 200 100 225 125 Main Device = Main lug only = Main breaker = Convertible = High AIC main breaker Note: All combinations are not valid, refer to the catalog section. 1 1 1 1 1 1 1 1 1 1 1 1 1 V1-T1-6 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com 1.1 Loadcenters and Circuit Breakers Type CH Loadcenters and Circuit Breakers Product Selection 1 Single-Phase—Main Circuit Breaker Loadcenters—10/25 kAIC CH42B200K 1 Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Split Neutral (Unless Otherwise Noted) Main Breaker Type Main Ampere Rating Maximum Number 3/4-Inch (19.1 mm) of Poles Enclosure Type Box Size Wire Size Range Cu/Al 60°C or 75°C for Main Breaker Loadcenter 12 Catalog Number CH 10 kAIC 100 14 Indoor B #6–1/0 125 CSR 25 kAIC 150 200 225 DK 10 kAIC 1 Loadcenter Cover Catalog Number Combination 3 Surface CH14B100B 4 CH8BF CH8BS 14 Outdoor B #6–1/0 CH14B100R 5 — — 18 Indoor C #6–1/0 CH18B100C 4 CH8CF CH8CS 18 Outdoor C #6–1/0 CH18B100R 5 — — 22 Indoor C #6–1/0 CH22B100C 4 CH8CF CH8CS 22 Outdoor C #6–1/0 CH22B100R 5 — — 30 Indoor D #6–1/0 CH30B100D 4 CH8DF CH8DS 30 Outdoor D #6–1/0 CH30B100R 5 — — 22 Indoor C #6–1/0 CH22B125C 4 CH8CF CH8CS 22 Outdoor C #6–1/0 CH22B125R 5 — — 30 Indoor D #6–1/0 CH30B125D 4 CH8DF CH8DS 30 Outdoor D #6–1/0 CH30B125R 5 — — 8 Outdoor E #2–300 kcmil CH8B150RF 6 — — 24 Indoor E #2–300 kcmil CH24B150E 4 CH8EF CH8ES 24 Outdoor E #2–300 kcmil CH24B150R 5 — — 32 Indoor J #2–300 kcmil CH32B150J 4 CH8JF CH8JS 32 Outdoor J #2–300 kcmil CH32B150R 5 — — 8 Outdoor E #2–300 kcmil CH8B200RF 6 — — 24 Indoor E #2–300 kcmil CH24B200E 4 CH8EF CH8ES 5 — — CH8JF CH8JS 24 Outdoor E #2–300 kcmil CH24B200R 32 Indoor J #2–300 kcmil CH32B200J 4 5 32 Outdoor J #2–300 kcmil CH32B200R — — 42 Indoor K #2–300 kcmil CH42B200K 4 CH8KF CH8KS 42 Outdoor K #2–300 kcmil CH42B200R 5 — — 32 Indoor J #2–300 kcmil CH32B225J 4 CH8JF CH8JS 32 Outdoor J #2–300 kcmil CH32B225R 5 — — 42 Indoor K #2–300 kcmil CH42B225K 4 CH8KF CH8KS 42 Outdoor K #2–300 kcmil CH42B225R 5 — — 7 CH7PMS CH7PMS 300 42 Indoor PM (2) 3/0–250 kcmil CH42PM300 CH7PMF 400 42 Indoor PM (2) 3/0–250 kcmil CH42PM400 CH7PMF 7 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Notes 1 All main circuit breaker loadcenters are listed for use as service entrance equipment. 2 Ground bar kits priced separately. See Page V1-T1-25. 3 Combination style covers may be used in surface or flush applications. 4 Can be top or bottom fed by rotating the enclosure and trim 180 degrees. 5 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-25. 6 Panel includes #4–300 kcmil feed-through lugs. 7 This cover is for flush applications only (not combination). 1 1 1 Box sizes Pages V1-T1-27 and V1-T1-28. 1 1 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-7 1.1 Loadcenters and Circuit Breakers Type CH Loadcenters and Circuit Breakers 1 Single-Phase—High Interrupting Rated Main Circuit Breaker Loadcenters—100 kAIC 1 Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Split Neutral 1 Main Breaker Type Main Ampere Rating Maximum Number 3/4-Inch (19.1 mm) Poles Enclosure Type Box Size Wire Size Range Cu/Al 60°C or 75°C for Main Breaker Loadcenter 1 Catalog Number 1 CHB4 100 kAIC 5 100 32 Indoor L #6–1/0 CH32H100L 3 4 1 CHH 100 kAIC 5 150 Loadcenter Cover Catalog Number Combination 2 Surface CH8LF CH8LS — — 32 Outdoor L #6–1/0 CH32H100R 32 Indoor L #2/0–300 kcmil CH32H150L CH8LF CH8LS 32 Outdoor L #2/0–300 kcmil CH32H150R 4 — — 32 Indoor L #2/0–300 kcmil CH32H200L CH8LF CH8LS 1 32 Outdoor L #2/0–300 kcmil CH32H200R 4 — — 42 Indoor L #2/0–300 kcmil CH42H200L CH8LF CH8LS 1 42 Outdoor L #2/0–300 kcmil CH42H200R 4 — — 42 Indoor L #2/0–300 kcmil CH42H225L CH8LF CH8LS — — 1 200 225 1 1 1 1 42 Outdoor L #2/0–300 kcmil CH42H225R Notes 1 All main circuit breaker loadcenters are listed for use as service entrance equipment. 2 Combination style covers may be used in surface or flush applications. 3 Loadcenter can be top or bottom fed by rotating the enclosure and trim 180 degrees. 4 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-25. 5 Series rated for 100 kAIC with all Types CH, CHT and CHP breakers. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V1-T1-8 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com 4 Loadcenters and Circuit Breakers Type CH Loadcenters and Circuit Breakers 1.1 Single-Phase—Main Lug Loadcenters 1 1 Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Single Neutral Surface Outdoor Main Ampere Rating Maximum Number 3/4-Inch (19.1 mm) Space Poles Enclosure Type Type of Trim (Included) 40 2 41 Indoor Surface (no door) 2 4 1 2 41 Box Size Wire Size Range Cu/Al 60°C or 75°C for Main Lugs Loadcenter Catalog Number 5 #14–6 CH2L40SP 23 234 Outdoor — 5R #14–6 CH2L40RP Indoor Flush (no door) 5 #14–6 CH2L40FP 23 1 1 1 1 1 Flush Outdoor 70 2 41 Indoor Surface (no door) 5 #14–2 CH2L70SP 23 2 41 Outdoor — 5R #14–2 CH2L70RP 234 2 41 Indoor Flush (no door) 5 #14–2 CH2L70FP 23 1 1 1 Surface (No Door) Flush (No Door) 125 2 41 Indoor Surface (no door) 6 #14–1/0 CH2L125SP 23 2 41 Outdoor — 6R #14–1/0 CH2L125RP 234 2 2 Outdoor — — #14–1/0 CH2L125RSE2P 456 2 41 Indoor Flush (no door) 6 #14–1/0 CH2L125FP 23 4 81 Indoor Surface (no door) 7 #14–1/0 CH4L125SP 27 4 81 Outdoor — 7R #14–1/0 CH4L125RP 247 4 81 Indoor Flush (no door) 7 #14–1/0 CH4L125FP 27 Outdoor — 6R #14–1/0 CH6L125R 267 Indoor Surface (no door) 7 #6–1/0 CH8L125SP 28 Outdoor — 7R #6–1/0 CH8L125RP 267 Indoor Flush (no door) 7 #6–1/0 CH8L125FP 28 1 6 12 8 16 1 8 16 1 8 16 1 1 1 1 1 1 1 1 1 1 Outdoor 1 1 Notes 1 Requires the use of Type CHNT breakers. 2 Ground bar kits priced separately, see Page V1-T1-25. – For 2/4 and 6/12 circuit loadcenters use Type GBK5 or GBK520 ground bar – For 4/8 and 8/16 circuit loadcenters use Type GBK10 ground bar – Ground bars mount to the left side wall of the enclosure for the 4/8, 6/12 and 8/16 circuit loadcenters 3 Suitable for use as service equipment when not more than two service disconnecting mains are provided or when not used as a lighting and appliance panelboard (see Article 408.34 of the NEC). 4 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-25. 5 For use as service entrance applications only. 6 Neutral/ground holes (6) #14–6 and (3) #14–2/0 AWG Cu/AI. 7 Suitable for use as service equipment when not more than two service disconnecting mains are provided or when not more than six service disconnecting mains are provided and when not used as a lighting and appliance panelboard (see Article 408.34 of the NEC). 8 Suitable for use as service equipment when a main breaker is used or when not more than six service disconnecting mains are provided and when not used as a lighting and appliance panelboard (see Article 408.34 of the NEC). Box sizes Pages V1-T1-27 and V1-T1-28. 1 1 1 1 1 1 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-9 1.1 1 CH42L225G 1 1 Loadcenters and Circuit Breakers Type CH Loadcenters and Circuit Breakers Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Split Neutral—Factory-Installed Ground Bar Loadcenter Cover Catalog Number Main Ampere Rating Maximum Number 3/4-Inch (19.1 mm) Poles Enclosure Type Box Size Wire Size Range Cu/Al 60°C or 75°C for Main Lugs Loadcenter Catalog Number Combination Surface 125 12 Indoor B #6–2/0 CH12L125B 1 CH8BF CH8BS 12 Outdoor B #6–2/0 CH12L125R 12 — — 1 1 16 Indoor B #6–2/0 CH16L125B CH8BF CH8BS 16 Outdoor B #6–2/0 CH16L125R 12 — — 20 Indoor C #6–2/0 CH20L125C 1 CH8CF CH8CS 1 20 Outdoor C #6–2/0 CH20L125R 12 — — 24 Indoor C #6–2/0 CH24L125C 1 CH8CF CH8CS 1 24 Outdoor C #6–2/0 CH24L125R 12 — — 1 150 1 24 Indoor D #4–300 kcmil CH24L150D 1 CH8DF CH8DS 24 Outdoor D #4–300 kcmil CH24L150R 23 — — CH8DF CH8DS 1 32 Indoor D #4–300 kcmil CH32L150D 32 Outdoor D #4–300 kcmil CH32L150R 23 — — 12 Indoor D #4–300 kcmil CH12L200D 1 CH8DF CH8DS 12 Outdoor D #4–300 kcmil CH12L200R 23 — — 16 Indoor D #4–300 kcmil CH16L200D 1 CH8DF CH8DS 16 Outdoor D #4–300 kcmil CH16L200R 23 — — 24 Indoor D #4–300 kcmil CH24L225D 1 CH8DF CH8DS 1 24 Outdoor D #4–300 kcmil CH24L225R 23 — — 32 Indoor D #4–300 kcmil CH32L225D CH8DF CH8DS 1 32 Outdoor D #4–300 kcmil CH32L225R 23 — — 42 Indoor G #4–300 kcmil CH42L225G 3 CH8GF CH8GS 42 Outdoor G #4–300 kcmil CH42L225R 23 — — 42 Indoor P (2) 1/0–300 kcmil (1) 750 kcmil CH42PL400 4 CH7PF 5 CH7PS 1 1 200 1 1 225 1 400 1 1 Notes 1 Suitable for use as service equipment when not more than six disconnecting means are provided and when not used as a lighting and appliance panelboard (see Article 408.34 of the NEC). 2 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-25. 3 Suitable for use as service equipment when a circuit breaker is used as a main breaker. The main breaker is backfed and requires hold-down bracket kit catalog number CH125RB. 4 Suitable for use as service equipment when a circuit breaker is used as a main breaker. The main breaker is backfed and must be a Type CHB. The breaker cannot be a Type CH. 5 This cover is for flush application only (not combination). 1 1 1 1 Box sizes Pages V1-T1-27 and V1-T1-28. 1 1 1 1 1 1 1 1 1 1 V1-T1-10 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com 1.1 Loadcenters and Circuit Breakers Type CH Loadcenters and Circuit Breakers Convertible Loadcenters MCB or MLO—Base Units and Main Devices—10/25/35 kAIC Complete assembly consists of: loadcenter, cover, and either main breaker kit or main lug kit. 1 1 Indoor—Single-Phase—Three-Wire—120/240V—Insulated/Bondable Split Neutral—Top or Bottom Feed Maximum Main Ampere Rating Maximum Number of Single Poles Box Size Loadcenter Box and Panel Catalog Number 1 125 22 C CH22N125C 200 225 32 42 J K CH32N200J Main Lug Kit Main Breaker Kit Combination Surface Wire Size Catalog Number kAIC Rating Wire Size Catalog Number CH8CF CH8CS #10–1/0 CHL125N 10 #10–1/0 CH2100N 3 — CH2125N 3 — CSR2125N CSH2125N 4 CSR2150N CSH2150N 4 CSR2175N CSH2175N 4 CSR2200N CSH2200N 4 CSR2125N CSH2125N 4 CSR2150N CSH2150N 4 CSR2175N CSH2175N 4 CSR2200N CSH2200N 4 CSR2225N CSH2225N 4 CH8JF CH42N225K 1 Loadcenter Cover Catalog Number CH8KF CH8JS CH8KS #4–300 kcmil #4–300 kcmil CHL225N CHL225N 25/35 2 25/35 2 #2–300 kcmil #2–300 kcmil 1 1 Maximum Number of Single Poles Loadcenter Box and Panel Catalog Number 1 Main Lug Kit Box Size Wire Size Catalog Number kAIC Rating Wire Size Catalog Number 125 22 C CH22N125R 5 #10–1/0 CHL125N 10 #10–1/0 CH2100N 3 CH2125N 3 — 200 8 E CH8N200RF 567 #4–300 kcmil CHL225N 25/35 2 #2–300 kcmil CSR2125N CSH2125N CSR2150N CSH2150N CSR2175N CSH2175N CSR2200N CSH2200N CSR2125N CSH2125N 4 CSR2150N CSH2150N 4 CSR2175N CSH2175N 4 CSR2200N CSH2200N 4 CSR2125N CSH2125N 4 CSR2150N CSH2150N 4 CSR2175N CSH2175N 4 CSR2200N CSH2200N 4 CSR2225N CSH2225N 4 225 42 J K CH32N200R 5 CH42N225R 5 #4–300 kcmil #4–300 kcmil Main Breaker Kit CHL225N CHL225N 25/35 2 25/35 2 #2–300 kcmil #2–300 kcmil 1 1 1 1 1 Maximum Main Ampere Rating 32 1 1 Outdoor—Single-Phase—Three-Wire—120/240V—Insulated/Bondable Split Neutral (Unless Otherwise Noted) 200 1 1 — 1 Notes 1 Panel does not include main. Order main breaker or main lug kit separately. 2 If 35 kAIC is required, use CSH breaker. 3 Hold-down kit included. 4 35 kAIC series combination rating is obtained when Types CH, CHT and CHP branch breakers are used with CSH main. 5 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-25. 6 Includes feed-through lugs for both phase and neutral conductors. 7 Insulated/bondable single neutral. 1 1 1 1 1 1 1 1 1 1 1 1 Interrupting rating depends on main circuit breaker selected. 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-11 1.1 Loadcenters and Circuit Breakers Type CH Loadcenters and Circuit Breakers 1 Three-Phase—Main Circuit Breaker Loadcenters—10 kAIC 1 CH42B3200L Three-Phase Four-Wire—208Y/120 Vac or 240 Vac Insulated/Bondable Split Neutral 1 1 Main Ampere Rating Maximum Number 3/4-Inch (19.1 mm) Poles Enclosure Type Box Size Wire Size Range Cu/Al 60°C or 75°C for Main Breaker Loadcenter 12 Catalog Number CC 10 kAIC 150 30 Indoor L #1–4/0 CH30B3150L CH8LF CH8LS 30 Outdoor L #1–4/0 CH30B3150R 3 — — 30 Indoor L #2/0–300 kcmil CH30B3200L CH8LF CH8LS 30 Outdoor L #2/0–300 kcmil CH30B3200R 3 — — 42 Indoor L #2/0–300 kcmil CH42B3200L CH8LF CH8LS 42 Outdoor L #2/0–300 kcmil CH42B3200R 3 — — 30 Indoor L #2/0–300 kcmil CH30B3225L CH8LF CH8LS 30 Outdoor L #2/0–300 kcmil CH30B3225R 3 — — 42 Indoor L #2/0–300 kcmil CH42B3225L CH8LF CH8LS 42 Outdoor L #2/0–300 kcmil CH42B3225R 3 — — 42 Indoor PM (2) 3/0–350 kcmil CH424PM400 CH7PMF 4 CH7PMS 200 1 1 1 225 1 1 1 Loadcenter Cover Catalog Number Main Breaker Type 400 Combination Surface Three-Phase—High Interrupting Rated Main Circuit Breaker Loadcenters—100 kAIC 1 1 Three-Phase Four-Wire—208Y/120 Vac or 240 Vac Insulated/Bondable Split Neutral Loadcenter Cover Catalog Number 1 Main Breaker Type Main Ampere Rating Maximum Number 3/4-Inch (19.1 mm) of Poles Enclosure Type Box Size Wire Size Range Cu/Al 60°C or 75°C for Main Breaker Loadcenter Catalog Number 12 1 CHH 100 kAIC 5 200 30 Indoor L #2/0–300 kcmil CH30H3200L CH8LF CH8LS 30 Outdoor L #2/0–300 kcmil CH30H3200R 3 — — 42 Indoor L #2/0–300 kcmil CH42H3200L CH8LF CH8LS 42 Outdoor L #2/0–300 kcmil CH42H3200R 3 — — 42 Indoor L #2/0–300 kcmil CH42H3225L CH8LF CH8LS — — 1 1 1 1 1 1 225 42 Outdoor L #2/0–300 kcmil CH42H3225R Notes 1 All main circuit breaker loadcenters are listed for use as service entrance equipment. 2 Ground bar kits priced separately. For ground bar kits, see Page V1-T1-25. 3 Rainproof loadcenters are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-25. 4 This cover for flush application only (not combination). 5 100 kAIC series combination rating is obtained when Types CH and CHP branch breakers are used with CHH main. 1 1 1 1 1 1 1 1 1 1 V1-T1-12 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com 3 Combination Surface 1.1 Loadcenters and Circuit Breakers Type CH Loadcenters and Circuit Breakers Three-Phase—Main Lug Loadcenters 1 Three-Phase Four-Wire—208Y/120 Vac or 240 Vac Insulated/Bondable Split Neutral (Unless Otherwise Noted) Main Ampere Rating Maximum Number 3/4-Inch (19.1 mm) Spaces 125 6 Poles Type of Trim Included Box Size Wire Size Range Cu/Al 60°C or 75°C for Main Lugs Loadcenter Catalog Number Combination Single 12 1 Indoor Surface, no door 7 #14–1/0 CH6L3125SP 234 — — 6 12 1 Outdoor — 7R #14–1/0 CH6L3125RP 2345 — — 6 12 1 Indoor Flush, no door 7 #14–1/0 CH6L3125FP — — 12 12 Indoor — B #6–2/0 CH12L3125B 67 CH8BF CH8BS 12 12 Outdoor — B #6–2/0 CH12L3125R 567 — — 18 18 Indoor — C #6–2/0 CH18L3125C 67 CH8CF CH8CS — — CH8CF CH8CS 234 678 18 18 Outdoor — C #6–2/0 CH18L3125R 24 24 Indoor — C #6–2/0 CH24L3125C 67 678 24 24 Outdoor — C #6–2/0 CH24L3125R — — 150 30 30 Indoor — D #4–300 kcmil CH30L3150D 67 CH8DF CH8DS 30 30 Outdoor — D #4–300 kcmil CH30L3150R 569 — — 225 24 24 Indoor — D #4–300 kcmil CH24L3225D 67 CH8DF CH8DS 24 24 Outdoor — D #4–300 kcmil CH24L3225R 569 — — 30 30 Indoor — D #4–300 kcmil CH30L3225D 67 CH8DF CH8DS 30 30 Outdoor — D #4–300 kcmil CH30L3225R 569 — — 42 42 Indoor — G #4–300 kcmil CH42L3225G 89 CH8GF CH8GS 400 1 Loadcenter Cover Catalog Number Enclosure Type 42 42 Outdoor — G #4–300 kcmil CH42L3225R 589 — — 42 42 Indoor — P (2) 1/0–300 kcmil (1) 750 kcmil CH424PL400 jk CH7PF l CH7PS 1 1 1 1 1 1 1 1 1 1 1 Notes 1 Requires the use of CHNT breakers. 2 Suitable for use as service equipment when not more than two service disconnecting means are provided or when not more than six service disconnecting means are provided and when not used as a lighting and appliance panelboard (see Article 408.34 of the NEC). 3 Ground bar kits priced separately, see Page V1-T1-25. – Use GBK10 ground bar – Ground bars mount to the left side wall of the enclosure. 4 Insulated/bondable single neutral. 5 Rainproof loadcenters are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-25. 6 Ground bar Type GBK14 is installed. 7 Suitable for use as service equipment when a circuit breaker is used as a main breaker. The main breaker is backfed and requires hold-down bracket kit catalog number Type CH125RB. Suitable for use as service equipment when not more than six service disconnecting means are provided and when not used as a lighting and appliance panelboard (see Article 408.34 of the NEC). 8 Ground bar Type GBK21 is installed. 9 Suitable for use as service equipment when a circuit breaker is used as a main breaker. The main breaker is backfed and requires hold-down kit catalog number Type CH125RB. j For ground bar kits, see Page V1-T1-25. k Suitable for use as service equipment when a circuit breaker is used as a main breaker. The main breaker is backfed and must be a Type CHB. The breaker cannot be a Type CH. l This cover for flush application only (not combination). 1 Box sizes Pages V1-T1-27 and V1-T1-28. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-13 1.1 1 Loadcenters and Circuit Breakers Type CH Loadcenters and Circuit Breakers Contents—CH Specialty Products Spa Panels Description 1 Page Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CH Specialty Products Spa Panels Surge Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . Plug-On Neutral Loadcenter . . . . . . . . . . . . . . . Type CH Renovation Loadcenter . . . . . . . . . . . . Type CH Retrofit Interior Kits . . . . . . . . . . . . . . CH Loadcenter Options and Accessories. . . . . . . . CH Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . 1 1 1 1 V1-T1-2 V1-T1-15 V1-T1-17 V1-T1-18 V1-T1-19 V1-T1-22 V1-T1-31 1 1 1 1 1 CH Specialty Products 1 Spa Panels 1 1 1 1 1 1 1 Product Description: Features Eaton’s CH Spa Panels are premium factory-assembled “combination” units that provide ground fault protection, as well as a convenient way to turn spa pumps on and off. The NEC requires that all pool and spa pumps be protected by a ground fault interrupter and a disconnect switch mounted within 10 feet of the tub or the spa. ● ● ● ● ● Two extra circuits for additional loads Limited lifetime warranty UL Listed Tough powder-coated galvanized steel enclosure Factory-installed two-pole ground fault circuit interrupter (GFCI) 1 1 Quick-ProSM All you need to know to save time and make more money. Specified on certain Eaton products, the Quick-Pro symbol allows for immediate recognition of products that are designed for straightforward installation. When you see Quick-Pro, you know you can install quickly— sometimes up to 50% less than the usual installation time—and move on to your next job. Product Selection 1 CH Spa Panel 1 Single-Phase Three-Wire—120/240 Vac Insulated/Bondable Neutral— Factory-Installed Ground Bar 1 Main Ampere Rating Circuit Breaker Included Enclosure Type Type of Trim Included Box Size Wire Size Range Cu/Al 60°C or 75°C for Main Lugs Catalog Number 1 30 CH230GF Outdoor — 5R #14–1/0 CH30SPA 1 1 40 CH240GF Outdoor — 5R #14–1/0 CH40SPA 2 50 CH250GF Outdoor — 5R #14–1/0 CH50SPA 3 60 CH260GF Outdoor — 5R #14–1/0 CH60SPA 4 1 Notes 1 Includes a CH230GFI breaker, factory installed, and two extra circuits for convenience. 2 Includes a CH240GFI breaker, factory installed, and two extra circuits for convenience. 3 Includes a CH250GFI breaker, factory installed, and two extra circuits for convenience. 4 Includes a CH260GFI breaker, factory installed, and two extra circuits for convenience. 1 1 1 V1-T1-14 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com Loadcenters and Circuit Breakers Type CH Loadcenters and Circuit Breakers 1.1 Contents—CH Specialty Products Surge Panel Description Page Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CH Specialty Products Spa Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . Surge Panel Plug-On Neutral Loadcenter. . . . . . . . . . . . . . . Type CH Renovation Loadcenter . . . . . . . . . . . Type CH Retrofit Interior Kits . . . . . . . . . . . . . . CH Loadcenter Options and Accessories . . . . . . . CH Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . 1 V1-T1-2 1 V1-T1-14 1 V1-T1-17 V1-T1-18 V1-T1-19 V1-T1-22 V1-T1-31 1 1 1 1 1 1 1 1 Surge Panel Product Description Eaton’s Type CH Surge Loadcenter includes a factorymounted and wired surge suppressor device. There is a knockout in the cover that allows the user to view the status indication lights on the surge suppressor. The CH Surge Loadcenter reduces the surge current, helping protect sensitive home electronic equipment. Save labor by installing a factorymounted surge protective device. Factory-Installed Surge Protection ● Includes a CHSPT2ULTRA and a two-pole 50A circuit breaker ● Increases the effectiveness of surge protection due to reduced lead length ● A modified deadfront allows for easy viewing of indicating lights 1 Product Selection 1 Surge Installed Loadcenters Ampere Rating 225 225 1 Loadcenter Cover Catalog Number Type Number of Circuits Loadcenter Catalog Number Combination Surface Convertible 42 CHSUR42N225L 1 CHSUR8LF CHSUR8LS Convertible 2 42 CHSUR42L225L2 1 CHSUR8LF CHSUR8LS 200 Main breaker 42 CHSUR42B200L2 1 CHSUR8LF CHSUR8LS 225 Convertible 32 CHSUR32N225K 1 CHSUR8KF CHSUR8KS 225 Convertible 2 32 CHSUR32L225K 1 CHSUR8KF CHSUR8KS 200 Main breaker 32 CHSUR32B200K 1 CHSUR8KF CHSUR8KS 150 Main breaker 32 CHSUR32B150K 1 CHSUR8KF CHSUR8KS 100 Main breaker 32 CHSUR32B100K 1 CHSUR8KF CHSUR8KS 125 Convertible 2 24 CHSUR24L125E 1 CHSUR8EF CHSUR8ES 100 Main breaker 24 CHSUR24B100E 1 CHSUR8EF CHSUR8ES 200 Convertible 40/40 BRSUR4040N200 Cover included 200 Main lug 40/40 BRSUR4040L200 Cover included 200 Main breaker 40/40 BRSUR4040B200 Cover included 200 Convertible 30/40 BRSUR3040N200 Cover included 200 Main lug 30/40 BRSUR3040L200 Cover included 200 Main breaker 30/40 BRSUR3040B200 Cover included 1 1 1 1 1 1 1 1 1 1 1 Notes 1 Order cover separately. 2 With main lugs installed. 1 1 Surge Ready ● Provides a mounting provision for CHSPT2ULTRA ● A modified deadfront allows for easy viewing of indicating lights 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-15 1.1 1 1 1 Loadcenters and Circuit Breakers Type CH Loadcenters and Circuit Breakers Surge Ready Loadcenters (provision only, CHSPT2ULTRA and breaker not included) Ampere Rating Number of Circuits Loadcenter Catalog Number 1 Loadcenter Cover Catalog Number Type Combination Surface 225 Convertible 42 CHEC42N225L CHSUR8LF CHSUR8LS 225 CHSUR8LF CHSUR8LS Convertible 2 42 CHEC42L225L 1 200 Main breaker 42 CHEC42B200L CHSUR8LF CHSUR8LS 225 Convertible 2 32 CHEC32L225K CHSUR8KF CHSUR8KS 1 225 Convertible 32 CHEC32N225K CHSUR8KF CHSUR8KS 225 Convertible 32 CHEC32N225R 3 — — 200 Main breaker 32 CHEC32B200K CHSUR8KF CHSUR8KS 150 Main breaker 32 CHEC32B150K CHSUR8KF CHSUR8KS 100 Main breaker 32 CHEC32B100K CHSUR8KF CHSUR8KS 125 Convertible 2 24 CHEC24L125E CHSUR8EF CHSUR8ES Main breaker 24 CHEC24B100E CHSUR8EF CHSUR8ES 1 1 1 100 1 1 Main Breaker Kits 1 Main Lug Kits Catalog Number Maximum Main Ampere Rating Catalog Number Maximum Main Ampere Rating 25 kAIC 35 kAIC 125 CHL125N 100 CSR2100N CSH2100N 1 225 CHL225N 150 CSR2150N CSH2150N 1 200 CSR2200N CSH2200N 225 CSR2225N CSH2225N 1 1 1 1 1 1 1 1 1 1 1 1 Technical Data and Specifications Ratings ● Loadcenter ● 25 kAIC main breaker, main lug only, and convertible main breaker/main lug ● Factory installed or provision for field-installed surge suppressor ● Top or bottom feed ● Surge protective device (CHSPT2ULTRA) ● Nominal discharge current: 20 kA (In) ● Surge current capacity per phase: 108 kA ● Warranty: $75,000 connected equipment 4 ● For further product ratings, see Volume 1, Tab 2.1 Surge Protection Notes 1 Order cover separately. 2 With main lugs installed. 3 Rainproof loadcenters are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-25. 4 For warranty details, visit www.eaton.com/surgetrap. 1 1 1 1 1 V1-T1-16 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com 1.1 Loadcenters and Circuit Breakers Type CH Loadcenters and Circuit Breakers Contents—CH Specialty Products 60-Circuit Plug-On Neutral Loadcenter Description Page Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CH Specialty Products Spa Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . Surge Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . Plug-On Neutral Loadcenter Type CH Renovation Loadcenter . . . . . . . . . . . Type CH Retrofit Interior Kits . . . . . . . . . . . . . . CH Loadcenter Options and Accessories . . . . . . . CH Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-2 V1-T1-14 V1-T1-15 V1-T1-18 V1-T1-19 V1-T1-22 V1-T1-31 1 1 1 1 1 1 1 1 1 1 1 Plug-On Neutral Loadcenter Product Description Code changes and higher safety standards are leading to more arc fault and ground fault circuit interrupter installations. Eaton offers a unique product solution that enables a direct connection of the breaker to the neutral bar, eliminating the need for wiring a pigtail. ● ● ● ● Time savings up to 25% per AFCI/GFCI installation Eliminates nuisance tripping due to loose pigtail connections Clean gutter space Easier troubleshooting due to less wiring Backed by a limited lifetime warranty 1 Main Breaker Plug-On Neutral Loadcenters Main Breaker Type Main Ampere Rating Max. Number 3/4-Inch Circuits Max. Number of Poles Enclosure Type CSR 25 kAIC 100 24 24 200 32 32 200 42 200 60 Features and Benefits ● 1 Product Selection 1 Cover Catalog Number Box Size Wire Size Range Cu/Al Catalog Number Combination Surface Indoor E #2–300 kcmil CH24BPN100E CH8EF CH8ES Indoor J #2–300 kcmil CH32BPN200J CH8JF CH8JS 42 Indoor K #2–300 kcmil CH42BPN200K CH8KF CH8KS 120 1 Indoor N #2–300 kcmil CH60BPN200N CH8NF — Main Lug Only/Convertible Plug-On Neutral Loadcenters—With Factory Installed Main Lugs Max. Ampere Rating Max. Number 3/4-Inch Poles Enclosure Type Box Size 125 24 Indoor E Cover Catalog Number 32 Indoor J Indoor K 1 1 Catalog Number Wire Size Range For Main Breaker CH24NLPN125E #6–300 kcmil CSR2100N #2–300 kcmil CH8NLEF CH8NLES 1 #2–300 kcmil CH8NLJF CH8NLJS 1 Combination Surface CH32NLPN225J #6–300 kcmil CSR2125N CH42NLPN225K #6–300 kcmil CSR2125N 1 1 CSR2100N 42 1 Main Breaker Kit 2 CSR2200N 225 1 Wire Size Range for Main Lug CSR2125N 225 1 #2–300 kcmil CH8NLKF CH8NLKS CSR2150N 1 1 CSR2200N Notes 1 Requires the use of type CHNT breakers. 2 If 35 kAIC is required, use CSH breaker equivalent. 1 1 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-17 1.1 1 Loadcenters and Circuit Breakers Type CH Loadcenters and Circuit Breakers Contents—CH Specialty Products Renovation Panel Description 1 Page Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CH Specialty Products Spa Panels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Surge Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . Plug-On Neutral Loadcenter . . . . . . . . . . . . . . . Type CH Renovation Loadcenter Type CH Retrofit Interior Kits . . . . . . . . . . . . . . CH Loadcenter Options and Accessories. . . . . . . . CH Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . 1 1 1 1 V1-T1-2 V1-T1-14 V1-T1-15 V1-T1-17 V1-T1-19 V1-T1-22 V1-T1-31 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Type CH Renovation Loadcenter Product Description Eaton’s Renovation Loadcenter is designed for the service contractor. With the addition of a fivecircuit terminal block factory mounted in the top left corner of the loadcenter, the service contractor can terminate short-circuit wires instead of having to use expensive wire nuts. Also, the Renovation Loadcenter incorporates a twin-stacked neutral design that places the neutral and ground terminations higher in the loadcenter. Both of these features were added without increasing any size from a standard loadcenter. These features will eliminate the need for wire nuts and make for a much neater installation. There is a provision to field mount a second five-circuit terminal block (RN5TB) in the top right corner of the loadcenter. Choose amongst Eaton’s Type CH breaker family for use in the Renovation Panel. Product Selection Single-Phase—Main Circuit Breaker Loadcenters 25 kAIC 1 Single-Phase, Three-Wire—120/240 Vac—Stacked Split Neutral Box Size Wire Size Range Cu/Al 60 or 70ºC for Main Breakers Loadcenter Catalog Number Combination Main Breaker Type Main Ampere Rating CH 100 20 Indoor C #6–1/0 CH22B100CRN CH8CFF CH8CS CSR 150 32 Indoor J #2–300 kcmil CH32B150JRN CH8JF CH8JS CSR 200 32 Indoor J #2–300 kcmil CH32B200JRN CH8J CH8JS CSR 200 42 Indoor K #2–300 kcmil CH42B200KRN CH8KF CH8KS Enclosure Type Branch Circuit Breakers (CH) See Pages V1-T1-2–V1-T1-13. Renovation Loadcenter Description Catalog Number Five-circuit terminal block kit Ground bar kits (two maximum per panel) RN5TB (See Page V1-T1-25) Notes 1 100A main breaker is rated 10 kAIC. 2 Combination style covers may be used in surface or flush applications. All main circuit breaker loadcenters are listed for use as service entrance equipment. Loadcenters are factory-bonded for service entrance applications. Remove bonding strap for separate neutral and ground bars for sub-feed applications. 1 1 1 1 V1-T1-18 Cover Catalog Number 2 Max. Number 3/4-Inch (19.1 mm) of Poles Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com Surface Loadcenters and Circuit Breakers Type CH Loadcenters and Circuit Breakers 1.1 Contents—CH Specialty Products Type CH Retrofit Interior Description Page Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CH Specialty Products Spa Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . Surge Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . Plug-On Neutral Loadcenter . . . . . . . . . . . . . . . Type CH Renovation Loadcenter . . . . . . . . . . . Type CH Retrofit Interior Kits CH Loadcenter Options and Accessories . . . . . . . CH Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . Type CH Retrofit Adjustable Interior V1-T1-2 V1-T1-14 V1-T1-15 V1-T1-17 V1-T1-18 V1-T1-22 V1-T1-31 1 1 1 1 1 1 1 Type CH Retrofit Interior Collar and Assembly with Trim 1 1 1 1 Type CH Retrofit Interior Kits Product Description Application Description Eaton’s unique Retrofit Interior allows the customer to cost-effectively and safely upgrade an electrical service without removing the existing enclosure from the wall. The Retrofit Interior is designed and tested specifically for renovating an outdated electrical panel in an apartment, a condominium or a single family home. These outdated panels are being recognized by local inspectors and other authorities as a possible hazard. Opportunities to Retrofit Single- or three-phase ● Main lug only or main breaker ● Up to 42 circuits ● Up to 225A interiors, 400A available upon request ● Available with CH breakers (3/4-inch) with copper bus or BR breakers (1-inch) with aluminum bus ● The minimum lifetime warranty for residential breakers shall be as follows: ● Limited lifetime warranty on all CH branch breakers and loadcenters ● Refer to Eaton for complete warranty details ● 1 Features and Benefits Upgrading Existing Electrical Infrastructure Is Simple ● Replaces vintage brands that have hard to find, expensive replacement breakers ● Safely upgrade to arc fault and ground fault breakers to meet current electrical codes ● Maximizes number of circuits available with compact design ● Eco-friendly in asbestosfilled environments ● Exclusive design Detailed Product Guide For questions about retrofit solutions, contact the Lincoln Flex Center at 800-330-6479 or flexcenterlincoln@eaton.com. Be sure to provide width, height and depth of panel. 1 1 1 Standards and Certifications 1 Meets 2008/2011/2014 NEC wire bending requirements. 1 1 1 1 1 Save Time and Money Throughout the Installation ● Uses existing panel box and wires ● Eliminates expensive and time-consuming drywall/ paint repair ● Saves 2–3 hours of installation time compared to a complete panel changeout ● Eliminates precise measurements with fieldadjustable kit 1 1 1 1 1 1 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-19 1.1 1 1 1 1 1 1 1 1 1 1 1 1 1 Loadcenters and Circuit Breakers Type CH Loadcenters and Circuit Breakers CH Specialty Product Selection To select the retrofit kit: 1. From the existing box size determine which retrofit groups are suitable (may be more than one). 2. Use type of interior, number of phases, and type of main to find the selection chart. 3. Select part number from chart (if main breaker, replace XXX with specific amp rating). 4. Note that the overlap of the existing wall is the retro cover size minus the existing box size. If specific measurements are needed, communicate that you need a custom trim size. 5. Contact the Lincoln Flex Center at 800-330-6479 for pricing, lead-times, and order entry instructions. How to Order: 1. Measure the existing panel enclosure to determine appropriate kits for your project. Need assistance or can’t find retrofit to fit existing enclosure? 2. Match the existing dimensions with the table below to obtain the correct catalog number. 3. Order your retrofit kit from a local Eaton authorized distributor. Email or call Eaton’s Residential Flex Center at 1-800-330-6479 for all your retrofit needs. Go to www.eaton.com/eccn to locate an Eaton Certified Contractor. Retrofit Interior Kit Specifications Five recommended groups: existing box height determines retro group size. Approximate Dimensions in Inches (mm). Existing Enclosure Parameters—Inches (mm) Catalog Number 1 Minimum Depth Maximum Depth Minimum Width Minimum Height Phase Main Bus Amperes 3 Spaces / Circuits UL 67 Listed CRWCH6ML**** 3.13 (79.5) 4.13 (104.9) 7.00 (177.8) 8.50 (215.9) Single MLO CH 125 6 No Cover 2 CH Retrofit Interiors and Covers RWCH6L125N RSCH10B125N CRWCH12ML**** 3.50 (88.9) 4.50 (114.3) 8.50 (215.9) 16.50 (419.1) Single MCB CH 125 10 No 1 RSCH12L125N CRWCH12ML**** 3.50 (88.9) 4.50 (114.3) 8.50 (215.9) 16.50 (419.1) Single MLO CH 125 12 No 1 RACH22B125J CRACH24ML**** 3.75 (95.3) 4.25 (108.0) 13.00 (330.2) 21.00 (533.4) Single MCB CH 125 22 No RACH24L125J CRACH24ML**** 3.75 (95.3) 4.25 (108.0) 13.00 (330.2) 21.00 (533.4) Single MLO CH 125 24 No 1 RBCH24B200_ CRBCH24CS**** 3.75 (95.3) 6.00 (152.4) 13.00 (330.2) 29.00 (736.6) Single MCB CH 200 24 No RBCH32L200_ CRBCH32ML**** 3.75 (95.3) 6.00 (152.4) 13.00 (330.2) 29.00 (736.6) Single MLO CH 200 32 No 1 RCCH32B200_ CRBCH32CS**** 3.75 (95.3) 6.00 (152.4) 13.00 (330.2) 34.00 (863.6) Single MCB CH 200 32 No 1 Notes 1 Catalog numbers shown with "_" at the end need one of the following suffixes to denote depth: J = 3.75–4.25 K = 4.25–5.00 L = 5.00–6.00 Example: RBCH24B200J would signify an interior set with a depth range of 3.75 to 4.25 inches. 2 ****Denotes characters in the catalog number that relate to overall cover size. Example: CRWCH6ML2620 would signify a cover 26.00 inches H x 20.00 inches W, or CRBCH24CS3324 would be 33.00 inches H x 24.00 inches W. 3 Amperes for MB panels is maximum; catalog number will reflect actual amperage of breaker included. 1 1 1 For UL applications, maximum cover sizes may apply. 1 1 1 1 1 1 1 1 1 V1-T1-20 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com Loadcenters and Circuit Breakers Type CH Loadcenters and Circuit Breakers 1.1 Complete Assembly Note: For complete assembly, interior and cover need to be ordered separately. Adjustable Interior ● ● ● ● Factory installed ground and neutral bars positioned to accept existing wires Field adjustable depth matches existing panel box Adjustable height enables optional placement of the interior Field bondable for service entrance options 1 Standard Trim and Collar ● ● ● 1 Standard trim matches new interior New circuit directory for updated labeling Oversized collar eliminates expensive wall/paint repair 1 1 1 1 1 1 1 1 Adjustable Interior 1 Collar and Assembly with Trim 1 Single-Phase—Main Lug Loadcenters, Non-Metallic 2460SNM 1 Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Neutral Main Ampere Rating 40 1 60 Maximum Number 1-Inch (25.4 mm) Wire Size Range Cu/Al 60°C or 75°C for Main Lugs 1 Enclosure Type Trim Type Box Size 4 Indoor Flush (no door) 2 4 4 Indoor Surface (no door) 2 2 4 Indoor Flush (no door) 2 2 4 Indoor Surface (no door) 2 2460SNM 2 4 Indoor Flush (no door) 2 2460FGNM 3 2 4 Indoor Surface (no door) 2 2460SGNM 3 — 4 2460RNM Spaces Circuits 4 2 4 Outdoor 2 Loadcenter Catalog Number 1 TT120FLGNM 23 1 TT120SLGNM 23 #14–2 2460FNM 1 Notes 1 Suitable for use as service equipment when not more than six main disconnecting means are provided and when not used as a lighting and appliance panelboard (see Article 408.34 of the NEC). 2 This device has no main lugs. A Type BR or BD breaker is required to be backfed to supply power to branch breakers. This device is single-phase 120 Vac only. With the use of three Type BR breakers, there are two branch circuits available. With the use of three Type BD breakers, there are five branch circuits available. 3 Includes GB4NM ground bar. 4 Includes a GFCB240 breaker, factory installed. 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-21 1.1 1 1 Loadcenters and Circuit Breakers Type CH Loadcenters and Circuit Breakers CH Loadcenter Options and Accessories CHSF2125 Field Installation and Parts 1 Description Ordering Quantity 1 Catalog Number Sub-feed lug blocks—two-pole, 125A, 3/4-inch (19.1 mm) spaces needed 1 CHSF2125 1 Sub-feed lug blocks—three-pole, 125A, 3/4-inch (19.1 mm) spaces needed 1 CHSF3125 Neutral/ground lug—add-on neutral or ground lug 1 NL20 1 NL30 1 NL300 1 Filler plates—3/4-inch (19.1 mm) space circuit breaker space 25 CHFP 1 CSR main circuit breaker filler plate (with hardware) 1 CSRFP Door lock—12–42 circuits, and 100–225A 1 TDL Sandlewood spray paint 1 SPCSW ANSI-61 light gray touchup paint for outdoor loadcenters 1 SPC61 Isolated neutral assembly (computer circuits) 1 BINA Circuit directory—adhesive backed 10 TCD 1 Cover screws 25 LCCS Cover replacement latch 14-5/16 inch (363.55 mm) wide loadcenters only 1 CHRLS 1 Circuit marking strip (next to breakers) 10 CHMS Circuit identification label (preprinted breaker labels next to breakers) 25 CHBL 1 Series rated caution label 25 SRL Branch circuit numbering strip 20 CHNS 1 Bonding strap with screw 1 BSSUSE 1 1 CHSF3125 CHFP 1 1 TDL BINA 1 1 Note 1 Must be purchased in multiples of ordering quantities indicated. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V1-T1-22 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com Loadcenters and Circuit Breakers Type CH Loadcenters and Circuit Breakers 1.1 Mechanical Interlock Covers Covers mechanically interlock two breakers. Type A covers interlock two CH breakers mounted across from one another. Type B covers interlock a main Type CSR breaker with a Type CH. CH8BRM Type A 1 1 1 Mechanical Interlocks Mechanical Interlock Trim/Deadfront Catalog Numbers 1 Type Fits Loadcenter Catalog Numbers Flush Surface A CH12L125B CH8BFM CH8BSM 1 1 CH16L125B CH12L3125B CH8EFM Type B 1 CH14B100B CH8CFM CH20L125C CH8CSM 1 CH24L125C 1 CH18L3125C CH24L3125C 1 CH22B100C CH22N100C CH8DFM CH24L150D 1 CH8DSM CH32L150D 1 CH24L3225D 1 CH30L3150D CH8GFM CH8GSM Inner cover of Box B raintight — CH8BRM Inner cover of Box C raintight — CH8CRM CH24B150E CHEFM CHESM 1 CH8JFM CH8JSM 1 CH42L225G 1 CH42L3225G 1 Indoor B CH24B200E CH32B150J 1 CH32B200J CH3242B200J 1 CH32N200J CH32B225J CH42B200K CH8KFM 1 CH8KSM 1 CH42N200K CH42B225K 1 Outoor B CH8B150RF CH3RDF7M — 1 CH8B200RF 1 CH8N200RF CH24B150R 1 CH24B200R CH32B150R CH3RDF9M — CH3RDF10M — 1 CH32B200R CH32N200R 1 CH32B225R CH42B200R 1 CH42N200R 1 CH42B225R 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-23 1.1 1 CH8BRM Type A Type CH Loadcenters and Circuit Breakers Mechanical Interlocks, contiuned Mechanical Interlock Trim/Deadfront Catalog Numbers 1 Type 1 Fits Loadcenter Catalog Numbers Flush Surface CHPC8B32LFM — CHPC8B42LFM — CH3RDF15M — CH3RDF16M — CH3RDF17M — CH3RDF18M — CH7JJFREPLM — CH7KKFREPLM — CH7LLFREPLM — Next Generation Power Center B 1 1 Loadcenters and Circuit Breakers CHPC32B150L CHPC32B200L CH8EFM Type B CHPC32N200L CHPC42B150L 1 CHPC42B200L CHPC42N200L 1 CHPC32B125TR 1 CHPC32B150TR CHPC32B200TR 1 CHPC32N200TR 1 CHPC42B200TR 1 CHPC32B150TR CHPC42B150TR CHPC42N200TR CHPC32B200TR 1 CHPC42B200BR 1 Vintage 1 CH20JJM200 1 CH24JJM150 1 CH30JJM200 CH30JJM150 1 CH30JJM150H 1 CH304JJM150 CH3040JJMM200 CH304JJM200 1 CH304JJM200H 1 CH40KKM200H CH30KKM225 1 CH40KKM225 1 CH40KKM225H 1 CH304KKM200H CH40KKM200H CH304KKM200 CH304LLM225 1 CH424LLM225H 1 Note 1 If vintage part number does not match exactly, the cover may not fit. Simple variations such as an “N” at the end of the part number contain minor design variations that will prevent our cover from working with that particular loadcenter. 1 1 1 1 1 1 V1-T1-24 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com Loadcenters and Circuit Breakers Type CH Loadcenters and Circuit Breakers DS100H1 1.1 Field Installation Rainproof Conduit Hubs Conduit Size Catalog Number 1 Description Inches (mm) Ordering Quantity 1 Group 1—for use with 70, 100 and 125A MLO and MCB loadcenters and circuit breaker enclosures 0.75 (19.1) 1 DS075H1 1.00 (25.4) 1 DS100H1 1.25 (31.8) 1 DS125H1 1.50 (38.1) 1 DS150H1 2.00 (50.8) 1 DS200H1 2.00 (50.8) 1 DS200H2 2.50 (63.5) 1 DS250H2 3.00 (76.2) 1 DS300H2 Adapter kit—allows installing a Group 1 hub on devices arranged for Group 2 hubs — 1 DS900AP Group 1—small blank hub closure plate — 1 DS900CP1 Group 2 —large blank hub closure plate — 1 DS900CP2 Group 2—for use with 150, 200 and 225A MLO and MCB loadcenters and circuit breaker enclosures 1 1 1 1 1 1 1 1 GBK14 Ground Bar Kits Length 1 Inches (mm) Ordering Quantity 2 dssssds 2.54 (64.5) 1 GBK5 2 dssssdsj 3.59 (91.2) 1 GBK520 2 dssssdssssss 4.29 (109.0) 1 GBK10 2 dssssdssssssj 5.34 (135.6) 1 GBK1020 2 1 4.61 (117.1) 1 GBK13 dssssdssssssssss 5.69 (144.5) 1 GBK14 2 dssssdssssssssssj 6.74 (171.2) 1 GBK1420 2 dssssdsssssssssssssssss 8.14 (206.8) 1 GBK21 2 dssssdsssssssssssssssssj 9.19 (233.4) 1 GBK2120 2 ssssssssdssssssdsssssss 7.94 (201.7) 1 CH9GP21 34 Ground Bar Legend s = (3) #14–#10 Cu/Al or (1) #14–#4 Cu/Al j = (1) #6–2/0 Cu/Al = (1) 1/0–14 or (3) #10–12 Cu/Al = (1) #14–1/0 Cu/Al or (3) #14–#10 Cu/Al d = Mounting hole f k Catalog Number 5 12–32 circuit main lug CHGRD1 Split neutral kit for 22-circuit 125A maximum CHSN125C Main lug and CHH main breaker panels CHGRD2 Split neutral kit for 32-circuit 200A maximum CHSN225J CC main CB panels CHGRD3 Split neutral kit for 42-circuit 200A maximum CHSN225K Replacement neutral for all C type boxes CHN125C Replacement neutral for all D type boxes CHN125D Replacement neutral for all L type boxes CHN225L Isolated Neutral Assembly (computer circuits) BINA 225 1 1 1 Neutral Bar Accessories Description 125 1 1 Kit Catalog Number 5 Three-Phase Loadcenter Types of Panels 1 1 Grounded “B” Phase Adapters Maximum Amperes 1 1 2 f d f f f k f d f k f f f Description (See Legend) Catalog Number Notes 1 Must be purchased in multiples of ordering quantities indicated. 2 Distance between mounting holes is 1-3/4 inches (44.5 mm). 3 For single- and three-phase 400A loadcenters. 4 Distance between mounting holes is 2-13/32 inches. 5 Cannot be used in Safety Breaker Panels. Classic Plus Panels only. 1 1 1 1 1 1 1 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-25 1.1 1 1 Loadcenters and Circuit Breakers Type CH Loadcenters and Circuit Breakers Decorator Cover Accessory ● For easy use with CH loadcenters mounted in living space ● Easily wallpapered or painted to match any decor ● Loadcenter accessory—exclusively from Eaton 1 1 Loadcenter Goof Collars Don’t let an ugly drywall problem ruin a beautiful electrical installation. Eaton’s Goof Collar is designed to cover gaps between the finished drywall and loadcenter enclosure. This is often necessary when upgrading the electrical service and the drywall surrounding the panel is damaged. The collar allows 2 inches of overhang beyond the standard flush trim. 1 1 SCOTT HAS PHOTO 1 1 1 1 Now you see it … … Now you don’t. 1 Decorator Cover Accessory 1 1 Corresponding Cover Existing CH Loadcenter Cover CH Goof Collars CH8BF CH8KDNB Inches (mm) 1 Before After Catalog Number CH8CF Catalog Number Height Width Loadcenter Cover CH8KDND 21.00 (533.4) 19.00 (482.6) CH8BF CH8BFC1921 19.00 (482.6) CH8CF CH8CFC1926 19.00 (482.6) CH8DF CH8DFC1934 CH8KDNC 1 CH8DF/EF CH8GF/JF CH8KDNJ 26.00 (660.4) 1 CH8KF CH8KDNK 34.00 (863.6) Goof Collar CH8EF 1 CHSUR8EF 39.00 (990.6) 1 19.00 (482.6) CH8GF CH8JFC1939 CH8JF 42.00 (1066.8) 1 19.00 (482.6) CH8KF CH8KFC1942 CHSUR8KF 44.00 (1117.6) 1 19.00 (482.6) CH8LF CH8LFC1944 CHSUR8LF 1 BR Goof Collars 1 Inches (mm) Height Width BR Box Size 1 21.00 (533.4) 19.00 (482.6) B1 BRB2GC2319 23.00 (584.2) 19.00 (482.6) B2 BRB1GC2119 25.00 (635.0) 19.00 (482.6) C1 BRC1GC2519 1 27.00 (685.8) 19.00 (482.6) C2 BRC2GC2719 31.00 (787.4) 19.00 (482.6) C4 BRC4GC3119 1 34.00 (863.6) 19.00 (482.6) D1 BRD1GC3419 1 1 1 Catalog Number Goof Collar 38.00 (965.2) 19.00 (482.6) G1 BRG1GC3819 43.00 (1092.2) 19.00 (482.6) L1 BRL1G4319 48.00 (1219.2) 19.00 (482.6) L2 BRL2GC4819 Note 1 For goof collars not listed in the table, please contact the Lincoln Flex Center at 1-800-330-6479. 1 1 1 V1-T1-26 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com 1.1 Loadcenters and Circuit Breakers Type CH Loadcenters and Circuit Breakers Dimensions 1 Approximate Dimensions in Inches (mm) Residential/Commercial/Unit Enclosure—Box Sizes 1 Residential Loadcenter Knockout Residential NEMA Type 1 Indoor and NEMA Type 3R Outdoor Enclosures. Note: Box sizes do not include covers/fronts. 1 Residential Loadcenters Box Size Height Width Depth 1 Knockouts for Box Sizes 5, 6, 7, 5R, 6R, 7R Code Diameter 5 9.50 (241.3) 4.50 (114.3) 3.13 (79.4) A 0.50 (12.7) 6 11.38 (288.9) 6.88 (174.6) 3.39 (86.1) B 0.50 (12.7) 0.75 (19.1) — — 0.50 (12.7) 0.75 (19.1) 1.00 (25.4) — NEMA Type 1 Indoor — — 1 — 1 7 13.00 (330.2) 11.00 (279.4) 3.69 (93.7) C B 16.75 (425.5) 14.31 (363.5) 3.88 (98.4) D 0.50 (12.7) 0.75 (19.1) 1.00 (25.4) 1.25 (31.8) 0.75 (19.1) 1.00 (25.4) 1.25 (31.8) — C 21.00 (533.4) 14.31 (363.5) 3.88 (98.4) E D 29.13 (739.8) 14.31 (363.5) 3.88 (98.4) F 0.75 (19.1) 1.00 (25.4) 1.25 (31.8) 1.50 (38.1) E 29.13 (739.8) 14.31 (363.5) 3.88 (98.4) G 1.00 (25.4) 1.25 (31.8) 1.50 (38.1) — G 34.13 (866.8) 14.31 (363.5) 3.88 (98.4) H 1.00 (25.4) 1.25 (31.8) 1.50 (38.1) 2.00 (50.8) J 34.13 (866.8) 14.31 (363.5) 3.88 (98.4) I 1.25 (31.8) 1.50 (38.1) 2.00 (50.8) — K 37.00 (939.8) 14.31 (363.5) 3.88 (98.4) L 39.00 (990.6) 14.31 (363.5) 3.88 (98.4) N 45.00 (1143.0) 14.31 (363.5) 3.88 (98.4) 9.50 (241.3) 4.50 (114.3) 3.13 (79.4) 6R 11.75 (298.5) 6.50 (165.1) 4.50 (114.3) 7R 13.00 (330.2) 11.00 (279.4) 3.69 (93.7) B 16.75 (425.5) 14.31 (363.5) 5.19 (131.8) C 21.00 (533.4) 14.31 (363.5) 5.19 (131.8) D 29.13 (739.8) 14.31 (363.5) 5.19 (131.8) E 29.13 (739.8) 14.31 (363.5) 5.19 (131.8) G 34.13 (866.8) 14.31 (363.5) 5.19 (131.8) J 34.13 (866.8) 14.31 (363.5) 5.19 (131.8) K 37.00 (939.8) 14.31 (363.5) 5.19 (131.8) L 39.00 (990.6) 14.31 (363.5) 5.19 (131.8) 1 F 1 Hub A 1 A D D F D D D A B A F 1 Box 5R 1 Hub A C F B Depth 1 A B H 1 D A F A Box 5 A Width A A D Commercial Loadcenters Height B F C 1 F 1 A D F F 1 D B NEMA Type 1 Indoor A P 54.38 (1381.1) 21.00 (533.4) 6.00 (152.4) PM 62.63 (1590.7) 21.00 (533.4) 6.00 (152.4) B Width B C 23.25 (590.6) G 8.88 (225.4) 4.50 (114.3) 9.31 (236.5) 5.44 (138.1) B A G 1 B H B 1 Box 6R B B 1 Hub A A A 1 B B G B A C NEMA Type 3R Outdoor 23.69 (601.7) A A A Depth NEMA Type 1 Indoor A H Box 6 Types ECB and ECC Unit Enclosures Height 1 1 Knockout Positions F Box Size 1 1 NEMA Type 3R Outdoor 5R 1 G B C C A A A B C F G A A A A Box 7 B B 1 C G G F C A A A B C G 1 G A A A A 1 B B Box 7R 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-27 1.1 1 1 1 1 Loadcenters and Circuit Breakers Type CH Loadcenters and Circuit Breakers Approximate Dimensions in Inches (mm) Residential and Commercial Loadcenter Knockout Residential NEMA Type 1 indoor and NEMA Type 3R outdoor enclosures. Knockouts for Box Sizes 8, 8R, P, PM, B, C, D, E, G, J, K, L, N and Outdoor Boxes 12–60 Circuits Type ECB and ECC Unit Enclosure Knockout Code Diameter Code Diameter a 0.75 (19.1) — — — — b 0.50 (12.7) 0.75 (19.1) — — — 1 c 0.50 (12.7) — — — — NEMA Type 3R Outdoor 1 d 1.00 (25.4) 1.25 (31.8) 1.50 (38.1) 2.00 (50.8) 2.50 (63.5) A 0.50 (12.7) e 1.25 (31.8) 1.50 (38.1) 2.00 (50.8) 2.50 (63.5) — B 1.25 (31.8) 1 f 0.75 (19.1) 1.25 (31.8) 1.50 (38.1) 2.00 (50.8) — g 0.50 (12.7) 0.75 (19.1) 1.00 (25.4) — — 1 h 1.50 (38.1) 2.00 (50.8) 2.50 (63.5) — — i 0.50 (12.7) 0.75 (19.1) 1.00 (25.4) 1.25 (31.8) 1.50 (38.1) 1 j 1.00 (25.4) 1.25 (31.8) 1.50 (38.1) — — 1 k 1.25 (31.8) 1.50 (38.1) 2.00 (50.8) — — m 0.75 (19.1) 1.00 (25.4) 1.25 (31.8) 1.50 (38.1) 2.00 (50.8) n 0.75 (19.1) 1.00 (25.4) 1.25 (31.8) 1.50 (38.1) — p 2.00 (50.8) 2.50 (63.5) — — — 1 1 1 1 NEMA Type 1 Indoor (Flush and Surface Trims) A 0.50 (12.7) — — — — B 1.25 (31.8) 1.50 (38.1) 1.75 (44.5) 2.00 (50.8) 2.50 (63.5) — — — — 1.50 (38.1) 1.75 (44.5) 2.00 (50.8) 2.50 (63.5) NEMA Type 1—Indoor A B B B B B B B Knockout Diagram B A b c 1 h NEMA Type 3R—Outdoor 1 HUB 1 1 c c c i c d c Flush Trim 3/4 b B b Outdoor Boxes 12–42 Circuits 225A Maximum 0.45 Dia. 1 i b c c c c d c c c c g g c e e Box P, PM 0.45 Dia. c b 1 1 e c 0.45 Dia. b b c c c g c c c 1 1 c 0.45 Dia. 1 1 c a 1 1 e e e 0.45 Dia. b b b c g b c i e e e B d c c c g g c e b b c g g g c b b b b b c c c b g g e e e 0.45 Dia. b g 0.45 Dia. b c c c c c c Box B 1 c c d c c e b i c b A e e g c c B 0.45 Dia. c c c c c B g c c c c b b b b c c b b b b c c g g e e e 0.45 Dia. 0.45 Dia. b b c c g c c c e c c c d c b i c c b Box C, D, E, G, J, K, L, N 1 1 V1-T1-28 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com Loadcenters and Circuit Breakers Type CH Loadcenters and Circuit Breakers 1.1 Technical Data and Specifications General A. The Contractor shall furnish and install loadcenters incorporating circuit breakers of the number, rating and type as specified herein and as shown on the contract drawings. Ratings A. Loadcenters shall be rated for 240 Vac and shall have short-circuit ratings as shown on the drawings or as herein scheduled, but not less than 10,000 amperes rms symmetrical. B. The loadcenter and all components shall be designed, manufactured and tested in accordance with the latest applicable standards of UL and NEMA including: B. Breakers shall be full size and a minimum of 125A frame. Breakers 10 –125A trip size shall take up the same pole spacing. 4. Federal Spec Classification W-C 375 C. Loadcenters shall be labeled with a UL shortcircuit rating. When series ratings are applied with integral or remote devices, a label shall be provided. Series ratings shall cover all trip ratings of installed frames. It shall state the conditions of the UL series ratings including: 5. UL 1699—all fault interrupting 1. Size and type of upstream device. Qualifications A. The manufacturer of the loadcenter shall be the manufacturer of the circuit breaker within the load center. All breakers shall be full size. 2. Branch devices that can be used. 1. UL 67—standards for panelboards 2. UL 50—standards for cabinets and boxes 3. UL 489—standards for molded case circuit breakers B. For the equipment specified herein, the manufacturer shall be ISO® 9000 certified. C. The manufacturer of this equipment shall have produced similar electrical equipment for a minimum period of seven (7) years. Manufacturers A. Eaton 3. UL series short-circuit rating. Construction A. All interiors, with the exception of the branch circuit breakers shall be completely factory assembled with main breakers, main lugs or no main device. B. Interiors shall be so designed that circuit breakers can be replaced without disturbing adjacent units and without removing the main bus connectors and shall be so designed that circuits may be changed without machining, drilling or tapping. C. Physical means must be provided to prevent the installation of more overcurrent devices than that number for which the enclosure was designed. Full size breakers are required. Bus A. Busbars for the main and cross connectors shall be of silver flash plated copper construction in accordance with UL standards. Bussing shall be braced to 65 kAIC. B. Neutral bussing shall have a suitable lug for each outgoing feeder requiring a neutral connection of same ampacity as branch. Wiring/Termination A. All wire connectors and terminals shall be of the anti-turn solderless type and suitable for copper or aluminum wire of the sizes indicated. All connectors shall meet the “Requirements for Wire Connectors and Soldering Lugs” UL 486B. B. All loadcenters where marked shall be suitable for use with 60/75°C rated wire. Circuit Breakers A. Circuit breakers shall be molded case type, 3/4-inch (19.1 mm) wide per pole. Multipole circuit breakers shall be of a stack pole design to provide electrical phase isolation and have an internal common trip. B. Each pole of the circuit breaker will have inverse time delay overload and instantaneous shortcircuit protection by means of both thermal and magnetic sensors. Circuit breakers shall be quick-make/quick-break. D. All circuit breakers shall be operated by a toggletype handle and multipole circuit breakers shall have an internal common trip mechanism. The circuit breakers shall incorporate trip mechanisms that are mechanically trip-free from the handle. The handle position shall provide good visual trip indication. E. Contacts shall be of nonwelding silver alloy. 1 1 1 1 1 1 1 1 F. All branch breaker handles shall be of a different color than the case of the breaker. 1 G. All terminals shall be listed for use with copper or aluminum conductors. Terminals shall be of the box lug design. The terminals shall meet UL 486B requirements and shall be suitable for use with either 60° or 75°C wire. 1 H. Breakers shall be SWD rated and/or HACR rated as required. I. Arc fault interrupting circuit breakers, (AFC), shall be provided on all 15 and 20A single-phase 120/240 Vac circuits except those indicated as remote controlled breakers. AFI breakers shall be “Classified for mitigating the effects of arcing faults,” or conforming to UL Standard 1699 and as defined by per Article 210.12 Section A of the NEC Code. C. The circuit breaker calibration shall not be affected by environmental changes in relative humidity. Breakers shall be calibrated after assembly. Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V1-T1-29 1.1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Loadcenters and Circuit Breakers Type CH Loadcenters and Circuit Breakers Enclosures A. Loadcenters shall have NEMA 1 general purpose or NEMA 3R rainproof enclosures as indicated on the drawings and shall be surface or flush mounted except where noted. B. For indoor applications, enclosures shall be rated NEMA 1. Enclosures shall be manufactured from cold-rolled codegauge sheet steel having multiple knockouts and painted per paint specification. For outdoor applications, enclosures shall be rated NEMA 3R. Enclosures shall be manufactured from galvanized steel which shall be painted per the painted as specified. Enclosures shall be of sufficient size to meet or exceed NEC wire bending space. Finish A. Boxes and trims shall be finished with a high scratch-resistant aesthetically pleasing finish. The finish shall be polyurethane coating electrostatically applied to a thickness of 1.8 to 2 mils. All loadcenters shall be provided with provisions for accepting a paintable or wall paperable decorator accessory cover. Where loadcenters are installed in living areas, provide manufacturer designed and tested decorator cover kits. C. The cover shall have an easy adjustment feature for flush applications. D. Boxes shall be factory assembled into a single rigid structure. E. Provide circuit breaker marking labels and directories. 1 1 1 1 1 1 1 1 1 1 1 1 V1-T1-30 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com Loadcenters and Circuit Breakers Type CH Loadcenters and Circuit Breakers 1.1 Contents Plug-On Circuit Breakers Description Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CH Specialty Products. . . . . . . . . . . . . . . . . . . . . . CH Loadcenter Options and Accessories . . . . . . . CH Circuit Breakers Product Selection . . . . . . . . . . . . . . . . . . . . . . . Options and Accessories . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Wiring Diagrams. . . . . . . . . . . . . . . . . . . . . . . . Page 1 V1-T1-2 V1-T1-14 V1-T1-22 1 V1-T1-32 V1-T1-38 V1-T1-40 V1-T1-40 1 1 1 1 1 1 1 1 1 CH Circuit Breakers Product Description Quick-make, quick-break switch mechanism combined with inverse time element tripping operation and tripfree handle design. Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multipole breakers have internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker. Special Application Plug-On Circuit Breakers—Type CH 10 kAIC 120 Vac and 120/240 Vac Branch Feeder Type Arc Fault Circuit Breakers A branch feeder type arc fault circuit interrupter is a device intended to mitigate high current arcing faults in the complete circuit, including connected cords. High current arcing faults can occur from line to neutral or line to ground. These arcing faults are in parallel with the load and produce the most energy of all arcing faults. The branch feeder type AFCI is required in the 1999 and 2002 National Electrical Code. The Combination Type AFCI is required in all subsequent editions of the National Electrical Code. Combination Type Arc Fault Circuit Breakers A combination type arc fault circuit interrupter is a device that offers mitigation of high current arcing faults in the complete circuit, including connected cords. In addition it provides direct detection of persistent low current arcing faults down to 5 amps with associated mitigation of fire hazards in the cords connected to the outlets. High current arcing faults can occur from line to neutral or line to ground. These arcing faults are in parallel with the load and produce the most energy of all arcing faults. The current level of low current arcing faults is limited by the load. Ground Fault Circuit Breakers—Ground Fault Application Notes Single-pole Type CHGFIs are designed for use in two-wire, 120 Vac circuits. The diagram on Page V1-T1-40 shows a typical wiring configuration. Two-pole Type CHGFIs are designed for use in threewire, 120/240 Vac circuits, 120 Vac multiwire circuits employing common, neutral and two-wire, 240 Vac circuits obtained from a 120/240 Vac source. Diagrams on Page V1-T1-40 illustrate typical wiring configurations for 120/240 Vac multiwire circuits. The diagram on Page V1-T1-40 depicts a 240 Vac, two-wire circuit. Note the “panel neutral” conductor connects to the neutral bar, even though the neutral is not included in the load circuit. This connection is necessary to supply a 120 Vac power source to the ground fault sensing circuit. The figures are shown with a 120/240 Vac, single-phase, three-wire power source, but are also applicable to a 120/208 Vac, three-phase, four-wire power supply. For all figures, the electrical operation of the Type CHGFI is not affected by the equipment ground. 1 1 1 1 1 1 1 1 1 1 Features Over-Center Toggle Spring Magnetic Armature 1 1 Current Bi-Metal Latch Lever Lug Screw Latch Spring Load Terminal 1 1 1 1 1 Line Contact Clip 1 Contact 1 Magnetic Pole Piece Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-31 1.1 Loadcenters and Circuit Breakers Type CH Loadcenters and Circuit Breakers 1 Product Selection 1 10 kAIC, 120 Vac, 120/240 Vac and 240 Vac 1 Type CH Plug-On Circuit Breakers Type CH Breakers, 3/4-Inch (19.1 mm) per Pole 120, 120/240 or 240 Vac, 10 kAIC Catalog Number 1 1 Ampere Rating 1 10 1 15 (1) #14–8 1 (2) #14–10 12 (1) #14–6 3 25 30 1 1 Two-Pole 120/240 Vac Common Trip Requires Two 3/4-Inch (19.1 mm) Spaces 5 per Shelf Carton Three-Pole 240 Vac Common Trip Requires Three 3/4-Inch (19.1 mm) Spaces 5 per Shelf Carton CH110 CH210 CH310 CH115 78 CH215 8 CH315 8 CH120 78 CH220 8 CH320 8 CH125 8 CH225 8 CH325 8 CH130 8 CH230 8 CH330 8 8 CH235 8 CH335 8 Wire Size Range Cu/Al 60ºC or 75°C 20 1 Single-Pole 120/240 Vac Requires One 3/4-Inch (19.1 mm) Space 10 per Shelf Carton 1 35 #14–2 #14–6 3 CH135 40 #10–1/0 4 #14–2 5 #3/0 6 CH140 8 CH240 8 CH340 8 CH145 8 CH245 8 CH345 8 8 CH250 8 CH350 8 1 45 50 CH150 1 60 CH160 CH260 CH360 70 CH170 CH270 CH370 1 80 — CH280 CH3080 90 — CH290 CH3090 1 100 — CH2100 CH3100 1 110 — CH2110 — 125 — CH2125 — 1 1 Type CH Plug-On Circuit Breakers CHF Breakers with Mechanical Trip Flag Catalog Number 1 1 Ampere Rating 1 10 15 1 (1) #14–8 1 (2) #14–10 12 25 30 1 35 1 45 40 50 1 Two-Pole 120/240 Vac Common Trip Requires Two 3/4-Inch (19.1 mm) Spaces 5 per Shelf Carton CHF110 CHF210 Wire Size Range Cu/Al 60ºC or 75°C 20 1 Single-Pole 120/240 Vac Requires One 3/4-Inch (19.1 mm) Space 10 per Shelf Carton #14–2 1 #10–1/0 #14–2 5 4 CHF115 78 CHF215 8 CHF120 78 CHF220 8 CHF125 8 CHF225 8 CHF130 8 CHF230 8 CHF135 8 CHF235 8 CHF140 8 CHF240 8 CHF145 8 CHF245 8 CHF150 8 CHF250 8 Notes 1 For single- and two-pole breakers. 2 Solid and stranded wire can be used together. 3 For three-pole breakers. 4 Single-pole 60–70A, two-pole 80–125A, three-pole 40–100A. 5 Single-pole 40–50A, two-pole 40–70A. 6 Two-pole 150A. 7 Switching duty rated. 8 HACR rated. 1 1 1 1 For factory-installed options, refer to Page V1-T1-39. 1 V1-T1-32 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com 1.1 Loadcenters and Circuit Breakers Type CH Loadcenters and Circuit Breakers Plug-On Branch Feeder Type Arc Fault Circuit Breakers, Type CH 10 kAIC, 120 Vac and 120/240 Vac Type CH AFCI SinglePole Circuit Breaker 1 1 Combination Type CH AFCI 3/4-Inch (19.1 mm) Wide Circuit Breakers Poles Ampere Rating Catalog Number Single-pole 10 kAIC 15 CHFCAF115 20 CHFCAF120 Two-pole 10 kAIC 15 CHCAF215 20 CHCAF220 1 Standard Pigtail 1 1 1 1 Type CH AFCI SinglePole Circuit Breaker 1 Branch Type CH AFCI 3/4-Inch (19.1 mm) Wide FIRE-GUARD® Circuit Breakers Poles Ampere Rating Configuration Catalog Number Single-pole 10 kAIC 15 AFCI CH115AF 1 20 AFCI CH120AF 1 15 AFCI common trip CH215AF 20 AFCI common trip CH220AF Two-pole 10 kAIC 23 1 1 1 1 1 1 1 Plug-On Combination Type Arc Fault Circuit Breakers and Ground Fault, Type CH 10 kAIC, 120 Vac and 120/240 Vac 4 Type CH AFCI SinglePole PON Combo Circuit Breaker 1 Combination Type CH AFCI 3/4-Inch (19.1 mm) and CHGFCI Circuit Breakers Poles Ampere Rating Configuration Catalog Number Single-pole 10 kAIC 15 AFCI plug-on neutral CHFCAF115PN 20 AFCI plug-on neutral CHFCAF120PN 15 GFCI plug-on neutral CHFGF115PN 20 CHFGF120PN 25 CHFGF125PN 30 CHFGF130PN 1 1 1 1 1 1 Notes 1 Clamshell packaging available with CS modification code on the end of catalog number. 2 Common trip refers to two-pole 240V load application sourced by 120/240 Vac (see diagram on Page V1-T1-40). 3 Independent trip refers to two-pole multi-wire, home run or shared neutral circuits (see diagrams on Page V1-T1-40). 4 Requires plug-on neutral loadcenter. 1 1 1 1 1 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-33 1.1 Loadcenters and Circuit Breakers Type CH Loadcenters and Circuit Breakers 1 Plug-On Ground Fault Circuit Breakers, Type CH 10 kAIC, 120 Vac and 120/240 Vac 1 Type CH Single-Pole Type CH Ground Fault Circuit Breakers (5 Milliampere) 3/4-Inch (19.1 mm) per Pole 120 Vac or 120/240 Vac,10 kAIC Catalog Number—1 per Shelf Carton 1 1 Single-Pole 120 Vac Requires One 3/4-Inch (19.1 mm) Space Two-Pole 120/240 Vac Common Trip Requires Two 3/4-Inch (19.1 mm) Spaces Ampere Rating Wire Size Range Cu/Al 60ºC or 75°C 1 15 #14–6 CHFGF115 CH215GF 1 20 #14–6 CHFGF120 CH220GF 1 25 #14–6 CHFGF125 CH225GF 30 #14–6 CHFGF130 CH230GF 1 35 #14–6 — CH235GF 40 #14–6 — CH240GF 1 45 #14–6 — CH245GF 50 #14–6 — CH250GF 60 #14–6 1 — CH260GF 1 1 1 Type CH Two-Pole Type CH Ground Fault Equipment Protectors (30 Milliampere) 3/4-Inch (19.1 mm) per Pole 120 Vac or 120/240 Vac, 10 kAIC 1 Catalog Number—1 per Shelf Carton 1 Single-Pole 120 Vac Requires One 3/4-Inch (19.1 mm) Space Two-Pole 120/240 Vac Common Trip Requires Two 3/4-Inch (19.1 mm) Spaces CH215EPD 1 Ampere Rating Wire Size Range Cu/Al 60ºC or 75°C 1 1 15 #14–6 CHFEP115 20 #14–6 CHFEP120 CH220EPD 1 25 #14–6 CHFEP125 — 30 #14–6 CHFEP130 CH230EPD 1 40 #14–6 — CH240EPD 1 50 #14–6 — CH250EPD 60 #14–6 1 — CH260EPD 1 1 Type CH Switching Neutral Breakers—10 kAIC, 120 Vac and 120/240 Vac Used to open the neutral along power line(s) for applications of gas pumps. 1 CH220SW 3/4-Inch (19.1 mm) per Pole 120/240 or 240 Vac, 10 kAIC Catalog Number—1 per Shelf Carton 1 Two-Pole 120 Vac Common Trip Requires Two 3/4-Inch (19.1 mm) Spaces 1 1 1 1 Wire Size Range Cu/Al 60ºC or 75°C 15 #14–8 CH215SW 2 CH315SW 3 20 #14–8 CH220SW 2 CH320SW 3 #14–8 CH230SW 2 CH330SW 3 CH240SW 2 CH340SW 3 CH250SW 2 CH350SW 3 40 50 1 #14–8 #14–8 Notes 1 60A breaker listed for 75°C Cu wire only. 2 For circuit breakers with shunt trip, add ST suffix. Shunt trip requires one additional pole space. 3 Switching duty rated. 1 1 V1-T1-34 Phase Phase Neutral Out Neutral In Ampere Rating 30 1 (Hot leg) Neutral Out Neutral In Three-Pole 120/240 Vac Common Trip Requires Three 3/4-Inch (19.1 mm) Spaces Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com Loadcenters and Circuit Breakers Type CH Loadcenters and Circuit Breakers 1.1 Type CH-HID Circuit Breakers—10 kAIC, 120 Vac, 120/240 and 240 Vac Suitable for use in circuits for fluorescent and high intensity discharge lighting. Also suitable for HACR applications. 1 1 3/4-Inch (19.1 mm) per Pole 120 Vac, 120/240 and 240 Vac, 10 kAIC Single-Pole 120/240 Vac Requires One 3/4-Inch (19.1 mm) Space Two-Pole 240 Vac Common Trip Requires Two 3/4-Inch (19.1 mm) Spaces Three-Pole 240 Vac Common Trip Requires Three 3/4-Inch (19.1 mm) Spaces 10 per Shelf Carton Catalog Number 5 per Shelf Carton Catalog Number 5 per Shelf Carton Catalog Number 1 1 1 Ampere Rating Wire Size Range Cu/Al 60ºC or 75° 15 #14–8 CH115HID CH215HID 1 CH315HID 20 #14–8 CH120HID CH220HID CH320HID 30 #14–8 CH130HID CH230HID CH330HID 1 1 1 1 Type CHT Twin 10 kAIC, 120/240 Vac, Universal CTL and Non-CTL Plug-On Circuit Breakers Suitable for CTL and Non-CTL CH loadcenters. Type CH and CHT Circuit Breakers Mounted in Twin Breaker Panel 1 Twin (CTL) 3/4-Inch (19.1 mm) per Pole 120 Vac Class CTL 10 kAIC Single-Pole Requires One 3/4-Inch (19.1 mm) Space 1 10 per Shelf Carton Catalog Number 1 Ampere Rating Wire Size Range Cu/Al 60ºC or 75°C 15–15 #14–8 CHT1515 23 15–20 #14–8 CHT1520 23 #14–8 23 20–20 1 120/240 Vac 120/240 Vac CHT2020 1 1 Notes 1 CH215HID is rated for 120/240V. 2 Switching duty rated. 3 HACR rated. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-35 1.1 1 1 Loadcenters and Circuit Breakers Type CH Loadcenters and Circuit Breakers Type CHP Commercial Breakers—10 kAIC, 120 Vac, 120/240 Vac and 240 Vac Note: CHP breakers feature on-off and trip positions for commercial applications. 3/4-Inch (19.1 mm) per Pole 120, 120/240 or 240 Vac, 10 kAIC 1 1 1 1 1 1 1 1 Ampere Rating Wire Size Range Cu/Al 60ºC or 75°C 10 (1) #14–8 1 (2) #14–10 12 (1) #14–6 3 Single-Pole 120/240 Vac Requires One 3/4-Inch (19.1 mm) Space Two-Pole 120/240 Vac Common Trip Requires Two 3/4-Inch (19.1 mm) Spaces Three-Pole 240 Vac Common Trip Requires Three 3/4-Inch (19.1 mm) Spaces 10 per Shelf Carton Catalog Number 5 per Shelf Carton Catalog Number 5 per Shelf Carton Catalog Number CHP110 CHP210 CHP310 CHP115 67 CHP215 7 CHP315 7 20 CHP120 67 CHP220 7 CHP320 7 25 CHP125 7 CHP225 7 CHP325 7 30 CHP130 7 CHP230 7 CHP330 7 7 CHP235 7 CHP335 7 15 1 35 #14–2 #14–6 3 CHP135 40 #10–1/0 4 #14–2 5 CHP140 7 CHP240 7 CHP340 7 7 7 CHP345 7 1 45 1 50 CHP150 7 CHP250 7 CHP350 7 60 CHP160 7 CHP260 7 CHP360 7 1 70 CHP170 CHP270 CHP370 80 — CHP280 — 1 90 — CHP290 — 100 — CHP2100 CHP3100 110 — CHP2110 — 125 — CHP2125 — 1 1 1 1 1 CHP145 Type CHP-GFCI Circuit Breakers—10 kAIC, 120 Vac and 120/240 Vac Note: CHP breakers offer on-off and trip positions for commercial applications. 5 Milliampere—3/4-Inch (19.1 mm) per Pole 120V and 120/240 Vac, 10 kAIC Single-Pole 120 Vac Requires One 3/4-Inch (19.1 mm) Space 1 1 per Individual Carton Catalog Number 1 1 Ampere Rating Wire Size Range Cu/Al 60ºC or 75°C 1 15 #14–6 CHP115GF 20 #14–6 CHP120GF 30 #14–6 CHP130GF 1 1 1 1 1 CHP245 Notes 1 For single- and two-pole breakers. 2 Solid and stranded wire can be used together. 3 For three-pole breakers. 4 Single-pole 60–70A, two-pole 80–125A, three-pole 40–100A. 5 Single-pole 40–50A, two-pole 40–70A. 6 Switching duty rated. 7 HACR rated. CHP breakers offer on-off and trip positions for commercial applications. 1 1 V1-T1-36 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com Loadcenters and Circuit Breakers Type CH Loadcenters and Circuit Breakers 1.1 Type CHP Neutral Switching Breakers—10 kAIC, 120 Vac and 120/240 Vac Used to open the neutral along power line(s) for applications of gas pumps. 1 1 3/4-Inch (19.1 mm) per Pole 120 or 120/240 Vac, 10 kAIC Two-Pole 120 Vac Common Trip Requires Two 3/4-Inch (19.1 mm) Spaces Three-Pole 120/240 Vac Common Trip Requires Three 3/4-Inch (19.1 mm) Spaces 1 per Shelf Carton Catalog Number 1 per Shelf Carton Catalog Number 1 1 1 Phase Phase Neutral Out Neutral In (Hot leg) Neutral Out Neutral In Ampere Rating Wire Size Range Cu/Al 60ºC or 75°C 15 #14–8 CHP215SW 1 CHP315SW 1 20 #14–8 CHP220SW 1 CHP320SW 1 1 1 Type CH-M50 High Ambient Breaker 1 3/4-Inch (19.1 mm) per Pole 120 or 120/240 Vac, 10 kAIC 1 Single-Pole 120/240 Vac Requires One 3/4-Inch (19.1 mm) Space Two-Pole 120/240 Vac Common Trip Requires Two 3/4-Inch (19.1 mm) Spaces 1 10 per Shelf Carton Catalog Number 5 per Shelf Carton Catalog Number 1 CH115M50 CH215M50 CH120M50 CH220M50 25 CH125M50 CH225M50 30 CH130M50 CH230M50 35 CH135M50 CH235M50 40 CH140M50 CH240M50 45 CH145M50 CH245M50 50 CH150M50 CH250M50 60 — CH260M50 70 — CH270M50 Ampere Rating Wire Size Range Cu/Al 60ºC or 75°C 15 (1) #14–8 (2) #14–10 20 1 1 1 1 1 1 1 Type CH-HM and CHP-HM High Magnetic Breakers 1 3/4-Inch (19.1 mm) per Pole 120 or 120/240 Vac, 10 kAIC 1 Single-Pole 120/240 Vac Requires One 3/4-Inch (19.1 mm) Space Two-Pole 120/240 Vac Common Trip Requires Two 3/4-Inch (19.1 mm) Spaces 1 10 per Shelf Carton Catalog Number 5 per Shelf Carton Catalog Number 1 Ampere Rating Wire Size Range Cu/Al 60ºC or 75°C 15 (1) #14–8 (2) #14–10 CH115HM CH215HM CH120HM CH220HM (1) #14–8 (2) #14–10 CHP115HM CHP215HM CHP120HM CHP220HM 20 15 20 1 1 1 1 Note 1 For circuit breakers with shunt trip, add ST suffix. Shunt trip requires one additional pole space, obtain pricing from Page V1-T1-39. 1 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-37 1.1 1 1 CHHT Field Installation Kits and Parts Description 1 Handle tie bar for physically joining the handles of two adjacent single-pole Type CH circuit breakers (molded plastic handle cover) CHPL CHHT CHPLGF Padlockable device for locking the handle of single-, two- or three-pole Type CH circuit breakers (escutcheon mounted) 5 1 CHPL 1 CHPLGF Padlockable device for locking the handle of main circuit breaker Types CC and CCH into the ON or OFF position.(screw mounted) 6 1 CCPL mounted) 5 1 MCBPL 10 CHLO Hold-down retainer kit for single-, two-, three-pole Type CH circuit breakers. For 6–24 circuit 125A single- and three-phase, 12–42 circuit single-phase 225A and 24–42 circuit three-phase 225A MLO Type CH loadcenters 1 CH125RB Hold-down retainer kit for single-, two-, three-pole Type CH circuit breakers for 2–4 circuit MLO CH loadcenters. 1 CH125RB24 1 CH9MB270 Padlockable device for locking the handle of main breaker Types BW and CSR into the ON or OFF position (escutcheon 1 Hold-Down Kits 9 Device used to secure handle in ON or OFF position for single-pole Type CH circuit breakers (handle mounted) 8 MCBPL 1 Mounting Bases CHLO Mounting base for two-pole Type CH circuit breaker—70A maximum Main Breaker Lug Kits 1 1 25 Padlockable device for locking the handle of a single-, two- or three-pole Type CHGFI circuit breaker (escutcheon mounted) 5 1 1 Catalog Number Handle Lockoffs 34 Handle Lockdogs 47 1 Ordering Quantity 1 Handle Ties 2 1 1 Type CH Loadcenters and Circuit Breakers Options and Accessories 1 1 Loadcenters and Circuit Breakers CH125RB Types CC and CCH main breaker lug kit (2) 300 kcmil 1 CCL300 Type CSR main breaker lug kit (2) 300 kcmil 1 MCBL300 10 CHML Mechanical Interlock Type CH for two-, three- and four-pole breakers 1 1 1 1 CH9MB270 1 1 1 1 CHML 1 1 1 Notes 1 Must be purchased in multiples of ordering quantities indicated. 2 Handle ties: typically used to join two similar independent single-pole breakers to form a two-pole noncommon trip breaker. 3 Handle lockoffs: devices that use a padlock to lock the circuit breaker’s handle in the ON or OFF position. 4 Requires one additional pole space. 5 Escutcheon mounted: device mounted semipermanently to the face of the circuit breaker and secured by the loadcenter deadfront. 6 Screw mounted: device permanently mounted to the face of the circuit breaker by the use of a non-removable screw. 7 Handle lockdogs: devices that are used to secure a circuit breaker’s handle in the ON or OFF position. Handle lockdogs are not padlockable devices. 8 Handle mounted: device mounted above or below handle using spring pressure. 9 Hold-down kits: devices used to secure the circuit breaker to the loadcenter for back-feed main application. See NEC Article 384.16(g). 1 1 1 1 1 V1-T1-38 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com Loadcenters and Circuit Breakers Type CH Loadcenters and Circuit Breakers 1.1 Shunt Trip Options Description Type Volts Catalog Number Suffix Adder 1 CSR 12 DC SR12 CSR 24 DC SR24 CSR 120 AC SR01 CH 120 AC ST 2 CC 12 DC SR12 CC 24 DC SR24 CC 120 AC SR01 CC 208 AC SR08 CC 240 AC SR02 1 1 1 1 1 1 1 1 Handle Position Changeability Chart 1 To Change Handle Position from ON to OFF or OFF to ON You Must... Handle Lockoff and Lockdog Types Remove Padlock Remove Device Remove Loadcenter Deadfront Lockoff escutcheon mounted Remove — — Lockoff screw mounted Remove — — Lockdog handle mounted N/A Remove — 1 1 1 1 Notes 1 Add suffix indicated to end of breaker catalog number. 2 Requires one additional pole space. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-39 1.1 Loadcenters and Circuit Breakers Type CH Loadcenters and Circuit Breakers 1 Technical Data and Specifications 1 Ratings Single- and two-pole CH breakers rated 15 and 20A have low instantaneous magnetic trip levels. The 15 and 20A breakers with “HM” suffix have high magnetic trip settings recommended for circuits with inherently high inrush currents. All Type CH breakers are marked for heating, air conditioning and refrigeration (HACR) equipment application. Single-pole 15–20A breakers are also suitable for switching duty (SWD). Shunt trip coils operate on 120 Vac and require one additional pole space per breaker. 1 1 1 1 1 1 1 Wiring Diagrams Typical Single-Pole Two-Pole 240V Load Application Sourced by 120/240 Vac 120/240 Vac Source N A B 120/240 Vac Source N A B 1 1 Line B Line B 1 Two-Pole Single-Pole Neutral Neutral 120V Duplex Receptacle 240V Duplex Receptacle Line A Neutral 1 Equipment Ground 1 1 Single-Pole 120V Load Application Sourced by 120/240 Vac Two-Pole Shared Neutral with Duplex Receptacle Application 1 120/240 Vac Source N A B 120/240 Vac Source N A B 1 Line B Line B Line A 1 1 Neutral Neutral 1 1 1 120V Duplex Receptacle Neutral Neutral Equipment Ground 1 1 Two-Pole Single-Pole 1 Two-Pole Shared Neutral with Multi-Duplex Receptacle Application Equipment Ground Single-Pole 120V Duplex Receptacle Application 120/240 Vac Source N A B 120/240 Vac Source N A B Line B Line B 1 Single-Pole Two-Pole 1 1 120V Duplex Receptacle (With Line Side Jumper Removed) Neutral Neutral Neutral Two 120V Duplex Receptacles Neutral 120V Duplex Receptacle Equipment Ground 1 Equipment Ground 1 V1-T1-40 Line A Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com Loadcenters and Circuit Breakers Type CH Loadcenters and Circuit Breakers 1.1 Two-Pole 120V Multi-Duplex Receptacle Application 1 120/240 Vac Source N A B 1 1 Line B 1 Two-Pole Neutral Neutral 1 Two 120V Duplex Receptacles 1 1 Line A 1 Two-Pole 120V Duplex Receptacle Application 1 120/240 Vac Source N A B 1 1 Line B Line A 1 Two-Pole Neutral Neutral 1 120V Duplex Receptacle (With Line Side Jumper Removed) 1 1 1 Two-Pole 240V Duplex Receptacle Application 1 120/240 Vac Source N A B 1 Line B 1 1 Two-Pole Line A Neutral 240V Duplex Receptacle 1 1 1 1 1 1 1 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-41 1.2 1 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Contents Description 1 Overview Product Description . . . . . . . . . . . . . . . . . . . . . Features, Benefits and Functions . . . . . . . . . . Standards and Certifications . . . . . . . . . . . . . . Catalog Number Selection . . . . . . . . . . . . . . . . Product Selection. . . . . . . . . . . . . . . . . . . . . . . BR Specialty Products Spa Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . Riser Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . Type BR Renovation Loadcenter . . . . . . . . . . . Type BR Mechanical Interlock Kits . . . . . . . . . . Type BR Retrofit Interior Kits . . . . . . . . . . . . . . BR Circuit Breakers. . . . . . . . . . . . . . . . . . . . . . . . 1 1 1 1 1 1 1 Page V1-T1-43 V1-T1-43 V1-T1-45 V1-T1-45 V1-T1-46 V1-T1-57 V1-T1-58 V1-T1-59 V1-T1-61 V1-T1-72 V1-T1-75 1 1 Overview 1 Product Selection Guide 1 BR Loadcenters 1 Description 1 Single-phase, three-wire, 120/240 Vac 1 Short-Circuit Current Rating Service 1 10 kAIC: All single- and three-phase loadcenters 70–225A, 8 to 42 circuits 22 kAIC: All convertible loadcenters using 125A rated Type BRH main breakers or selected factory installed 125A rated Type BRH main breaker 1 Main Breaker/Main Lug Loadcenters 1 1 1 Single-phase Main breaker: 100, 125, 150, 200, 225, 400, 600A Main lugs: 70, 125, 150, 200, 225, 400, 600A Main breaker: single-phase up to 200A and three-phase up to 225A 1 Enclosures 1 NEMA Type 1 indoor NEMA Type 3R outdoor 1 Loadcenter and Breaker Accessories 1 1 1 Three-phase Main breaker: 100, 125, 150, 200, 225, 400, 600A Main lugs: 100, 125, 150, 200, 225, 400, 600A Main lugs: single-phase up to 200A and three-phase up to 150A Branch Breakers 1 1 25 kAIC: All convertible and factory-installed single-phase loadcenters rated 150 and 200A using Type CSR main breakers Convertible Loadcenters Types BR, BRH and BRHH: 10–150A. single-, two- and three-pole; selected amperage available in switching duty, HACR, shunt trip and high magnetic setting Type GFCB: 15–60A Types BJ and BJH: 125–225A; two- and three-pole Type BD Twin: 10–50A; two of one-pole; take one 1-inch (25.4 mm) space 1 Three-phase, four-wire, 208Y/120 Vac Three-phase, three-wire, 240 Vac delta Type BQ and BQC Multibreaker: 15–30A. Two of two-pole or one two-pole and two one-pole; takes two 1-inch (25.4 mm) spaces Type BRW: 15–30A; two-pole water heater breakers Type BRSN: 15–30A; two-pole switching neutral breakers Type BR 15–100A; two-pole, 240 Vac delta breakers BR-AFCI arc fault circuit interrupter NEMA 4X Meets or exceeds UL requirements for indoor or outdoor applications Branch circuit breaker: Auxiliary components Hold-down kits Handle ties Lockoffs Lockdogs Complete line of ground bar kits 5, 10, 14 and 21 circuit, some with additional #2/0 lugs; each terminal will accommodate: (3) #14–#10 Cu/Al or (1) #14–#4 Cu/Al Main and sub-feed lugs 125, 150, 225A—two- and three-pole Shunt trips Surge protection: Single-phase plug-on surge protector Single-phase bottle type surge protector Three-phase bottle type surge protector Single-phase whole home surge protector Universal rainproof conduit hubs Group One: 3/4, 1, 1-1/4, 1-1/2, 2 inches (19.1, 25.4, 31.8, 38.1, 50.8 mm) Group Two: 2, 2-1/2, 3 inches (50.8, 63.5, 76.2 mm) Adapter plate Bussing Tin-plated aluminum as standard V1-T1-42 Limited copper bus panels available Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers 1.2 Product Description Loadcenters are enclosures specifically designed to house the branch circuit breakers and wiring required to distribute power to individual circuits. They contain either a main breaker when used at the service entrance point or a main lug when used as a sub-panel to add circuits to existing service. The main breaker protects the main entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets. Features, Benefits and Functions Loadcenter Construction Eaton’s Type BR loadcenters have standard tin-plated aluminum bus with a limited availability of copper bus. The sum of the handle ratings connected to any stab is limited to 150A maximum on the 100 and 125A loadcenters, and 200A on loadcenters with 150A or higher main bus. NEMA Type 1 boxes or enclosures are manufactured from galvanized steel. Raintight boxes are manufactured from galvanized steel, then finished using an electrostatic powder coat, baked urethane paint process. Neutrals Eaton Type CH loadcenters feature two types of neutrals: Insulated/Bondable Split Neutral Panels are supplied with split insulated neutrals with an insulated cross strap. For service entrance applications, the neutral must be bonded by using the bonding strap supplied with the panel. For non-service entrance (subpanel) applications, the panel may be installed with the bonding strap not connected to the neutral. Separate ground bars must be used on non-service entrance panels. Insulated/Bondable Single Neutral Panels are supplied with a single insulated neutral. For service entrance applications, all that is required to bond the neutral is to loosen the bonding screw and the neutral screw directly beside it, insert the bonding strap into the neutral bar, and retighten both connections. The single neutral can be moved by the contractor to the other side of the panel, if desired. When used as a service entrance panel, unused neutral connections may be used for the termination of equipment grounds. For nonservice entrance (sub-panel) applications, the panel may be installed with the bonding strap not connected to the neutral. Separate ground bars must be used on non-service entrance panels. Grounds In service entrance applications where the neutral is bonded, unused neutral holes may be used for terminating ground conductors. In sub-feed panels, the neutral must be isolated (non-bonded), and ground wires must be terminated on a separate ground bar. The insulated/bondable single/split neutral panels have sufficient terminations for both ground and neutral conductors. The insulated/ bondable single split neutral panels are supplied with a separate factory-installed ground bar if the catalog number contains a “G.” If not, a separate ground bar should be installed. Insulated/ Bondable Single Neutral panels are supplied without a ground bar (unless otherwise noted), and ground bar kits if needed must be purchased separately. Neutral and Ground Terminals The standard terminals on grounds and neutrals are rated to accept (3) #14–#10 Cu/Al or (1) #14–4, provided the cables terminated are of the same material. For larger cables, add-on neutral lugs may be ordered from the accessories on Page V1-T1-65. Note: NEC allows only one current-carrying conductor per hole on neutrals unless otherwise noted. Bottom Fed Loadcenters For single-phase 225A and below loadcenters that are bottom fed, a standard panel can be rotated 180 degrees to allow straight-in wiring of power cables to the main terminals. Because the main circuit breaker handle operates horizontally, the orientation of the main circuit breaker handle is consistent with the requirements of NEC 2008 Article 240.81. Gutter Splicing Loadcenters are not UL listed as wiring troughs. Therefore, gutter splicing of riser cables to tap off to the main device is not permitted. Refer to NEC 2008 Article 312.8. Fire Rating Due to the numerous openings in both loadcenter boxes and trims, they should not be mounted in firewalls. There is no approved method for sealing the enclosures for this application. Date Code The date of manufacture of each loadcenter is printed on the outside of the carton as well as inside the loadcenter. On the carton, the date code is printed on the end carton label. In the loadcenter, the date code is located on the small white label located on the right side wall (with the main device on top). 1 1 1 1 1 1 The date code is in the following format: F # # # &. The “F” is the numeric code for the Lincoln, IL plant, and the three numbers are the year and week of manufacturing, e.g., 023. The “!” sign at the end signifies the decade of the 2010. Therefore, the date code F023& would indicate that the product was manufactured in the 23rd week of 2010. The 1980s are represented by the “+” sign and the 1990s are represented by a “=” at the end of the code. 1 Surge Protectors Complete home surge protection is available in multiple options, including a factory-installed option that provides the highest level of surge protection in a residential design. See Tab 3 for more details. 1 Circuit Breaker Case Interrupting Capacity ● 10 kAIC ● 22 kAIC ● 25 kAIC 1 1 1 1 1 1 1 1 1 1 1 1 1 Warranty Information ● 10-year limited loadcenter warranty ● 10-year limited branch breaker warranty 1 1 1 1 1 1 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-43 1.2 1 1 1 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Type BR Loadcenter Extra 1.5 inch Knockout (38.1 mm) ■ Larger knockout provides easier installation and time savings 1 1 1 Top or Bottom Feed ■ Straight-in wiring saves labor and material ■ 1 1 1 1 1 1 1 1 “Tangential” Center Knockout Easier installation for conduit applications ■ Commercial Grade Main Breaker ■ 25 kAIC series rated main breaker for superior protection One panel for either top or bottom applications Neutral Bus (Strap) ■ 2/0 Lug ■ Easily removable and can be installed in any location on the neutral bar Type BR AFCI Breakers ■ Compact design for easier wiring and improved wireway access ■ ■ Optional LED indicates one of six trip codes for circuit diagnostics Provides a clean gutter space Is easily removable for sub-panel applications Bonding Z-Strap Provides easy field conversion for service entrance applications ■ Twin Neutral Bars Minimum 150% neutral capacity ■ 1 1 1 1 Standard Tin-Plated Aluminum Bus ■ Excellent conductivity and corrosion resistance ■ 1 1 1 Copper bus options available for select catalog numbers Drywall Marking on Enclosure Indicates proper mounting depth for flush applications ■ 1 Single Keyhole Mounting One keyhole at the top and bottom provides easier mounting and leveling ■ 1 1 1 1 Steel Backpan Provides solid and reliable breaker mounting—single piece design for stability and durability ■ Warranty 10-year warranty on all Type BR loadcenters and circuit breakers. 1 1 1 1 V1-T1-44 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com 1.2 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Standards and Certifications Catalog Number Selection UL Listings All Eaton Type BR loadcenters are listed under UL File E52977 except the 2–8 circuit loadcenters, up through and including 125A, which are listed under UL File E8741. Single- and Three-Phase Through 225A 1 3 BR 1 30 42 B C 200 1 Phase Construction Blank = Single-phase 1 3 = Three-phase Blank = No feed thru lugs 1 F = Feed-through lugs G = Ground bar P = Current design NY = NY City gutter space Main Device B = Main breaker L = Main lug N = Convertible main H = Main breaker high AIC Eaton’s Type BR Loadcenter Factory Options SUR = Factory integrated surge Enclosure = NEMA Type 3R rainproof = NEMA Type 1 indoor with surface trim F = NEMA Type 1 indoor with flush trim Blank = NEMA Type 1 indoor with combination trim 1 RIS = Riser panel R S Bus Number of 1-Inch (25.4 mm) Spaces Blank = Aluminum bus 1 C = Copper bus Maximum Number of Circuits 50 70 100 125 1 1 1 1 1 1 1 1 Amperes = 50A 150 = 150A = 70A 200 = 200A = 100A 225 = 225A = 125A 1 1 1 Single- and Three-Phase 400–600A 3 B 30 42 D F N Phase Blank = Single-phase 1 3 = Three-phase 1 1 N = Current design Main Blank = Main lug 1 B = Main breaker Amperes D = 400A E = 600A Number of 1-Inch (25.4 mm) Spaces Maximum Number of Circuits 1 Enclosure F = NEMA Type 1 indoor with combination trim S = NEMA Type 1 indoor with surface trim R1 = NEMA Type 3R rainproof 1 1 1 1 Example No. 1: BR1224L125G Example No. 2: BR24L70RP Example No. 3: 3B4242EFN Single-phase Type BR loadcenter rated at 125A with main lugs, 12 spaces allowing 24 poles, indoor combination enclosure, aluminum bus and ground bar. Single-phase Type BR loadcenter rated at 70A with main lugs, two spaces allowing four poles, rainproof enclosure with aluminum bus. Three-phase Type BR loadcenter rated at 600A with main breaker, 42 spaces allowing 42 poles, indoor combination enclosure. 1 1 1 1 Note 1 No character space used. 1 1 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-45 1.2 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers 1 Product Selection 1 Single-Phase—Main Circuit Breaker Loadcenters—10/25 kAIC 1 BR4040B200 Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Split Neutral 1 Main Breaker Type Main Ampere Rating Maximum Number 1-Inch (25.4 mm) Spaces Circuits Enclosure Type Box Size Wire Size Range Cu/Al 60°C or 75°C for Main Breaker Loadcenter Catalog Number with Combination 1 or NEMA Type 3R Cover 1 BR 10 kAIC 100 8 16 Indoor B1 #4–1/0 2 BR816B100 10 20 Indoor A1 BR1020B100S11 1 10 20 Indoor A1 BR1020B100F11 10 20 Outdoor B2R BR1020B100RF 34 1 12 12 Indoor B2 BR1212B100 12 20 Indoor B2 BR1220B100 1 12 24 Outdoor B2R BR1224B100R 4 16 16 Indoor C1 BR1616B100 1 16 20 Indoor C1 BR1620B100 16 24 Outdoor C1R BR1624B100R 4 20 24 Outdoor C3R BR2024B100R 4 20 20 Indoor C2 BR2020B100 16 24 Indoor C1 BR1624B100 30 30 Indoor D1 16 24 Indoor C1 20 24 Indoor C1 20 24 Outdoor C3R BR2024B125R 4 30 30 Indoor D1 BR3030B125 20 24 Indoor C2 #4–1/0 BR2024H100 6 #2–300 kcmil BR816B150RF 34 1 1 125 1 1 1 BRH 6 22 kAIC 100 CSR 7 25 kAIC 150 BR3030B100 #4–2/0 BR1624B125 BR2024B125 8 16 Outdoor C3R 16 30 Indoor C4 BR1630B150 20 30 Indoor C4 BR2030B150 1 20 30 Outdoor D1R BR2030B150R 4 20 40 Indoor D1 BR2040B150 1 20 40 Outdoor D1R BR2040B150R 4 24 30 Indoor G1 BR2430B150 30 30 Outdoor G1R BR3030B150R 4 30 30 Indoor G1 BR3030B150 30 40 Indoor G1 4 8 Outdoor 8R 1 8 16 Outdoor C3R BR816B200RF 34 16 32 Indoor C4 BR1632B200 1 20 40 Outdoor D1R BR2040B200R 4 20 40 Indoor D1 BR2040B200 1 24 40 Indoor G1 BR2440B200 30 40 Outdoor G1R BR3040B200R 4 30 40 Indoor G1 BR3040B200 j 40 40 Outdoor L1R BR4040B200R 4 40 40 Indoor L1 BR4040B200 40 50 Indoor L1 42 42 Indoor L2 42 42 Outdoor L2R 1 1 1 200 1 1 225 1 BR3040B150 #2–300 kcmil BR48B200RF 389 BR4050B200 #1–250 kcmil BR4242B225 BR4242B225R 4 Notes 1 Combination style covers may be used in surface or flush applications. 2 Wire range size for BR1020B100SP is #6–#1 Cu/Al. 3 Includes through-feed lugs for both phase and neutral conductors. 4 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-65. 5 See copper bus offering, Page V1-T1-53. 6 22 kAIC series combination rating is obtained when Types BD, BR, BQ, BQC and GFCB 10 kAIC branch breakers are used in series with Type BRH main breaker. 7 25 kAIC series combination rating is obtained when Types BD, BR, BQ, BQC and GFCB 10 kAIC branch circuit breakers are used in series with Type CSR main breaker. 8 Supplied with adapter plate to use DS Group1 hubs on Page V1-T1-65. If 2.50-inch (63.5 mm) hub is needed, remove adapter and use ARP00007CH25 hub. 9 Neutral is bonded—suitable for service entrance only—cannot be converted for sub-feed application. j Add G to the end of the catalog number for factory-installed GBK2120 ground bar. All main circuit breaker loadcenters are listed for use as service entrance equipment and are shipped with neutral bonding strap preattached. The maximum rating of the panel is the main circuit breaker rating when used as service entrance equipment. Ground bar kits priced separately. See Page V1-T1-65. 1 1 1 1 1 V1-T1-46 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com 1.2 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Main Circuit Breaker Loadcenters—10/22 kAIC B4242DFN 1 Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Split Neutral Main Breaker Type Main Ampere Rating DK 4 HLD 6 Maximum Number 1-Inch (25.4 mm) Spaces Circuits Enclosure Type Box Size Wire Size Range Cu/Al 60°C or 75°C for Main Breaker 300 42 42 Indoor 24 400 42 42 Indoor 24 42 42 Outdoor 42 42 Indoor 600 1 Commercial Loadcenter Catalog Number 123 With Flush or NEMA Type 3R Cover With Surface Cover (2) #3/0–250 kcmil BR304242F BR304242S (2) #3/0–250 kcmil B4242DFN B4242DSN 47 (2) #3/0–250 kcmil B4242DR1N 5 — 24 (2) #3/0–500 kcmil B4242EFN B4242ESN 1 1 1 1 Notes 1 Ground bar kits priced separately. See Page V1-T1-65. 2 The maximum rating of the panel is the main circuit breaker rating when used as service entrance equipment. 3 Door lock and key included with loadcenter. 4 Type DK main circuit breaker is rated 65 kAIC at 240 Vac and allows a 22 kAIC series rating on the panel when Types BR, BD and BJ branch circuit breakers are used. 5 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-65. 6 Type HLD main circuit breaker is rated 65 kAIC at 240 Vac. Type HLD circuit breaker is not series rated with Types BR, BD and BJ branch circuit breakers. Box sizes Pages V1-T1-66 through V1-T1-69. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-47 1.2 1 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Single-Phase—Main Lug Loadcenters 1 Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Split Neutral 1 Main Ampere Rating 1 Spaces Circuits Enclosure Type Trim Type Box Size Wire Size Range Cu/Al 60°C or 75°C for Main Lugs Loadcenter Catalog Number BR24L70SP 12 2 4 Indoor Surface (no door) 5 2 4 Indoor Surface (no door) 5 BR24L70SGP 23 2 4 Outdoor — 5R BR24L70RP 124 2 4 Indoor Flush (no door) 5 BR24L70FP 12 2 4 Indoor Flush (no door) 5 2 4 Indoor Surface (no door) 6 2 4 Outdoor — 6R BR24L125RP 124 2 4 Outdoor — 6R BR24L125RSEP 278 2 4 Outdoor — 6R BR24L125RSE2P 267 1 2 4 Indoor Flush (no door) 6 BR24L125FP 12 4 8 Indoor Surface (no door) 7 1 4 8 Indoor Surface (no door) 7 BR48L125SGP 39 4 8 Outdoor — 7R BR48L125RP 149 1 4 8 Indoor Flush (no door) 7 BR48L125FP 19 4 8 Indoor Flush (with door) 7 BR48L125FDP 19 1 4 8 Indoor Flush (no door) 7 6 12 Indoor Surface (no door) 7 1 6 12 Indoor Surface (no door) 7 BR612L125SGP jk 6 12 Indoor Surface (with door) 7 BR612L125SDP 1j 6 12 Indoor Surface (with door) 7 BR612L125SDGP jk 6 12 Outdoor — 7R BR612L125RP 14j 6 12 Indoor Flush (no door) 7 BR612L125FP 1j 6 12 Indoor Flush (no door) 7 BR612L125FGP 5jk 6 12 Indoor Flush (with door) 7 BR612L125FDP j 6 12 Indoor Flush (with door) 7 BR612L125FDGP 5jk 8 16 Indoor Surface (no door) 7 8 16 Indoor Surface (no door) 7 BR816L125SGP jl 8 16 Indoor Surface (with door) 7 BR816L125SDP 1j 1 8 16 Indoor Surface (with door) 7 BR816L125SDGP jl 1 8 16 Outdoor — 7R BR816L125RP 14j 8 16 Indoor Flush (no door) 7 BR816L125FP 1j 8 16 Indoor Flush (no door) 7 BR816L125FGP 5jl 8 16 Indoor Flush (with door) 7 BR816L125FDP 1j 8 16 Indoor Flush (with door) 7 BR816L125FDGP 5jl Surface Outdoor 70 Maximum Number 1-Inch (25.4 mm) 1 1 1 125 Flush Outdoor 1 1 Surface (No Door) Flush (No Door) 1 1 1 Outdoor 1 1 1 #8–#2 BR24L70FGP 25 #14–1/0 #14–1/0 BR24L125SP 12 BR48L125SP 19 BR48L125FGP 39 #14–#1 #14–#1 BR612L125SP 1j BR816L125SP 1j Notes 1 Ground bar kits priced separately. See Page V1-T1-65. – For 2/4 circuit loadcenters, use GBK5 or GBK520 ground bar. – For 4/8, 6/12 and 8/16 circuit loadcenters, use GBK10 ground bar. – Ground bars mount to the left side wall of the enclosure for the 4/8, 6/12 and 8/16 circuit loadcenters. 2 Suitable for use as service equipment when not more than two service disconnecting mains are provided or when not used as a lighting and appliance panelboard (see Article 408.34 of the NEC). 3 Ground bar GBK5 is installed. 4 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-65. 5 CSA and UL approved. 6 Neutral/ground holes (6) #14–6 and (3) #14–2/0 AWG Cu/Al. 7 For use as service entrance applications only. 8 Neutral/ground holes (6) #14–6 and (3) #14–1/0 AWG Cu/Al. 9 Suitable for use as service equipment when not more than two service disconnecting mains are provided or when not more than six service disconnecting mains are provided and when not used as a lighting and appliance panelboard (see Article 408.34 of the NEC). j Suitable for use as service equipment when a main breaker is used or when not more than six service disconnecting mains are provided and when not used as a lighting and appliance panelboard (see Article 408.34 of the NEC). k Ground bar GBK10 is installed. l Ground bar GBK14 is installed. 1 1 1 1 1 1 1 1 Box sizes Pages V1-T1-66 through V1-T1-69. V1-T1-48 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com 1.2 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Single-Phase—Main Lug Loadcenters 1 1 Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Split Neutral, continued Main Ampere Rating BR1224L125 125 150 BR1224L200 200 225 Maximum Number 1-Inch (25.4 mm) Spaces Circuits Enclosure Type Box Size Wire Size Range Cu/Al 60°C or 75°C for Main Lugs 12 12 Indoor B1 #6–2/0 Loadcenter Catalog Number with Combination or NEMA Type 3R Cover 1 BR1212L125 2345 24 Indoor B1 BR1224L125 12 24 Indoor B1 BR1224L125G 245 12 24 Indoor B1 BR1224L125DG 2456 12 24 Outdoor B1R BR1224L125R 257 16 16 Indoor B2 BR1616L125 245 16 24 Indoor B2 BR1624L125 24 16 24 Indoor B2 BR1624L125G 24 24 Outdoor B2R BR1624L125R 20 20 Indoor C1 BR2020L125 245 20 24 Indoor C1 BR2024L125 24 20 24 Indoor C1 BR2024L125G 248 20 24 Outdoor C1R BR2024L125R 27 24 24 Indoor C2 BR2424L125 24 24 24 Indoor C2 BR2424L125G 248 BR3042L125 1 1 1 1 1 1 1 24 30 42 Indoor D1 16 30 Indoor C2 20 30 Indoor C2 8 16 Outdoor B2R 12 24 Indoor B2 BR1224L200 459 12 24 Outdoor B2R BR1224L200R 579 20 40 Indoor C2 BR2040L200 49 20 40 Indoor C2 BR2040L200G 489 20 40 Outdoor C3R BR2040L200R 79 24 40 Indoor C4 BR2440L200 49 30 40 Indoor D1 BR3040L200 49 30 40 Indoor D1 BR3040L200G 489 30 40 Outdoor D1R BR3040L200R 79 40 40 Indoor G1 BR4040L200 49 40 40 Indoor G1 BR4040L200G 49 40 40 Outdoor G1R BR4040L200R 79 42 42 Indoor L1 42 42 Outdoor L1R #1–300 kcmil 1 27 16 BR1630L150 49 1 BR2030L150 49 #1–300 kcmil #1–300 kcmil 1 1 245 12 1 BR816L200RF 57j 1 1 1 1 1 1 1 1 BR4242L225 4 BR4242L225R 7 Notes 1 Ground bar kits priced separately unless otherwise noted. See Page V1-T1-65. 2 Has notch for BREQS125 hold-down kit. 3 Single, movable neutral is provided. 4 Combination cover style. 5 Suitable for use as service equipment when not more than six main disconnecting means are provided and when not used as a lighting and appliance panelboard (see Article 408.34 of the NEC). 6 Ground bars GBK5 and GBK520 installed. 7 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-65. 8 Ground bar GBK1220 installed. 9 Has notch for BRHDK125 hold-down kit. j Includes through-feed lugs for both phase and neutral conductors. 1 1 1 1 1 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-49 1.2 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers 1 Single-Phase—Main Lug Loadcenters—400 and 600A 1 4242DFN Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Split Neutral Maximum Number 1-Inch (25.4 mm) 1 1 Main Ampere Rating Spaces Circuits Enclosure Type Box Size 400 12 24 Indoor 19 1 1 1 600 1 Wire Size Range Cu/Al 60°C or 75°C for Main Lugs (1) #4/0–750 kcmil or (2) #3/0–400 kcmil Commercial Loadcenter Catalog Number 123 With Flush or NEMA Type 3R Cover With Surface Cover — 1224DSN 5 12 24 Outdoor 42 24 42 Indoor 20 — 42 42 Indoor 22 4242DFN 4242DSN 42 42 Outdoor 46 4242DR1N 4 — 42 42 Indoor 22 — 4242ESN (2) #2–500 kcmil 1224DR1N 45 — 2442DSN Notes 1 Ground bar kits priced separately unless otherwise noted. See Page V1-T1-65. 2 Has notch for BRHDK125 hold-down kit. 3 Ground bar GBK8 installed. 4 Rainproof panels are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-65. 5 Suitable for use as service equipment when not more than six main disconnecting means are provided and when not used as a lighting and appliance panelboard (see Article 408.34 of the NEC). 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V1-T1-50 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com 1.2 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Convertible Loadcenters MCB or MLO—Base Units and Main Devices 10/22/25 kAIC, Complete Assembly Consists of: Loadcenter and Either Main Breaker Kit or Main Lug Kit 1 Note: Interrupting rating depends on main circuit breaker selected. 1 BR3040N200 1 Base Units—Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Split Neutral (Unless Otherwise Noted) Main Ampere Rating 1 125 4 200 8 Maximum Number 1-Inch (25.4 mm) Spaces Circuits Enclosure Type 12 24 Indoor Box Size B2 Wire Size Range Cu/Al 60°C or 75°C for Main Loadcenter Catalog Number With Combination or NEMA Type 3R Cover 23 See main breaker and main lug kit tables Page V1-T1-54. BR1224N125 56 24 Outdoor B2R 16 24 Indoor C1 BR1624N125 5 16 24 Outdoor C1R BR1624N125R 57 1 1 5 20 24 Indoor C2 BR2024N125 20 24 Outdoor C3R BR2024N125R 57 8 16 Outdoor C3R BR816N200RF 79jk 12 24 Indoor C4 BR1224N200 j 12 24 Outdoor C3R BR1224N200R 7j 16 32 Indoor C4 BR1632N200 j 20 40 Indoor D1 BR2040N200 j 20 40 Indoor D1 BR2040N200G l 20 40 Outdoor D1R BR2040N200R 7j 20 40 Outdoor D1R BR2040N200RG l 24 40 Indoor G1 BR2440N200 7j 30 40 Indoor G1 BR3040N200 j 30 40 Indoor G1 BR3040N200G l 30 40 Outdoor G1R BR3040N200R 7j 30 40 Outdoor G1R BR3040N200RG l 40 40 Indoor L1 BR4040N200 j 40 40 Indoor L1 BR4040N200G l 40 40 Outdoor L1R BR4040N200R 7j 40 40 Outdoor L1R BR4040N200RG l 1 1 BR1224N125R 567 12 1 1 1 1 1 1 1 1 1 1 1 Notes 1 The maximum rating of the loadcenter is the main circuit breaker rating when used as service entrance equipment. 2 100, 125 and 200A convertible base unit catalog numbers include interior, box and cover only. Main devices and accessories must be ordered separately for field installation. All convertible base units are listed as suitable for use as service entrance equipment when used per Article 384 of the NEC. 3 Ground bar kits priced separately except as noted, refer to Page V1-T1-65. 4 For main breaker, use Type BR. For main lug use Type BRSF. 5 BREQS125 hold-down screw comes with loadcenter for back-fed Types BR and BRH main circuit breakers. 6 Convertible to maximum of 100A main circuit breaker and 125A main lug. 7 Rainproof loadcenters are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-65. 8 For main breaker, use Type BW or CSR. For main lug, use Type BRL. 9 Includes through-feed lugs for both phase and neutral conductors. j No hold-down provisions for back-fed Types BR and BRH main circuit breakers. k Insulated/bondable single neutral. l Includes GBK2120 ground bar. 1 1 1 1 1 1 1 1 1 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-51 1.2 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers 1 Convertible Loadcenters MCB or MLO—Base Units and Main Devices 10/22/25 kAIC, Complete Assembly Consists of: Loadcenter and Either Main Breaker Kit or Main Lug Kit 1 Note: Interrupting rating depends on main circuit breaker selected. 1 BW2200 1 Main Devices—Two- and Three-Pole Main Circuit Breakers—120/240 Vac or 208Y/120 Vac or 240 Vac Ampere Rating 1 Wire Size Range Cu/Al 60°C or 75°C for Main Breaker 10 kAIC 22/25 kAIC Catalog Number Catalog Number 1 Main Devices—Two- and Three-Pole Main Lug Kits—120/240 Vac or 208Y/120 Vac or 240 Vac BRL200 Ampere Rating Catalog Number Two-Pole Two-Pole 1 Wire Size Range Cu/Al 60°C or 75°C for Main Lugs 100 #4–1/0 BR2100 BRH2100 125 #6–2/0 BRSF125 1 110 #4–1/0 BR2110 BRH2110 150 #1–300 kcmil BRL200 125 #4–2/0 BR2125 BRH2125 175 #1–300 kcmil BRL200 1 125 #2–300 kcmil BW2125 CSR2125N 200 #1–300 kcmil BRL200 #6–3/0 3BRSF150 150 #2–300 kcmil BW2150 CSR2150N Three-Pole 1 175 #2–300 kcmil BW2175 CSR2175N 150 1 200 #2–300 kcmil BW2200 CSR2200N Three-Pole BR3100 BRH3100 100 1 1 1 1 #1 Main Circuit Breaker with Accessory Example: BW22005R01 (Put description with catalog number on order. See Page V1-T1-86.) Main Circuit Breaker Loadcenters—Copper Bus 10/22/25 kAIC BR3030BC100 Main Circuit Breaker Loadcenters—With Copper Bus—Single-Phase Three-Wire—120/240 Vac— Insulated/Bondable Split Neutral 1 Main Breaker Type Main Ampere Rating 1 BR 10 kAIC 100 1 BRH 22 kAIC 4 1 CSR 25 kAIC 1 Maximum Number 1-Inch (25.4 mm) 20 20 Indoor C2 #4–1/0 BR2020BC100 30 30 Indoor D1 #4–1/0 BR3030BC100 100 30 30 Indoor D1 #4–1/0 BR3030HC100 150 30 30 Indoor G1 #2–300 kcmil BR3030BC150 200 20 40 Indoor D1 #2–300 kcmil BR2040BC200 30 40 Indoor G1 #2–300 kcmil BR3040BC200 40 40 Indoor L1 #2–300 kcmil BR4040BC200 Main Lug Only Loadcenters—Copper Bus 1 BR816LC125FDP Single-Phase Three-Wire—120/240 Vac—Insulated/Bondable Single Neutral with Copper Bus Main Ampere Rating 125 1 1 Loadcenter Catalog Number with Combination Cover 23 Circuits 1 1 Wire Size Range Cu/Al 60°C or 75°C for Main Breaker Spaces 1 1 Box Size Enclosure Type Maximum Number 1-Inch (25.4 mm) Trim Type Box Size Wire Size Range Cu/Al 60°C or 75°C for Main Lugs Loadcenter Catalog Number #14–1 BR816LC125SDP Spaces Circuits Enclosure Type 8 16 Indoor Surface (with door) 7 8 16 Indoor Flush (with door) 7 BR816LC125FDP Notes 1 Series combination rating with Types BD, BR, BQ, BQC and GFCB is 22 kAIC with BRH main and 25 kAIC with CSR main. 2 All main circuit breaker loadcenters are listed for use as service entrance equipment and are shipped with neutral bonding strap preattached. The maximum rating of the panel is the main circuit breaker rating when used as service entrance equipment. 3 Ground bar kits priced separately. See Page V1-T1-65. 4 22 kAIC series combination rating is obtained when Types BD, BR, BQ, BQC and GFCB 10 kAIC branch breakers are used in series with Type BRH main breaker. 1 1 1 Box sizes Pages V1-T1-66 through V1-T1-69. 1 V1-T1-52 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com 1.2 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Convertible Loadcenters—Copper Bus 10/22/25 kAIC BR3040NC200 1 Convertible—Single-Phase, Three-Wire—120/240 Vac—Insulated/Bondable Split Neutral Main Ampere Rating 125 10/22 kAIC 45 200 10/25 kAIC 49 Maximum Number 1-Inch (25.4 mm) Spaces Circuits Enclosure Type Box Size 12 24 Indoor B2 12 24 Outdoor B2R Wire Size Range Cu/Al 60°C or 75°C for Main Loadcenter Catalog Number (With Combination or NEMA Type 3R Cover) 123 See main breaker and main lug kit tables on Page V1-T1-54. BR1224NC125 67 1 7 24 Indoor C2 BR2024NC125 20 24 Outdoor C3R BR2024NC125R 78 20 40 Indoor D1 BR2040NC200 20 40 Outdoor D1R BR2040NC200R 8 30 40 Indoor G1 BR3040NC200 30 40 Outdoor G1R BR3040NC200R 8 40 40 Indoor L1 BR4040NC200 40 40 Outdoor L1R BR4040NC200R 8 1 1 BR1224NC125R 678 20 1 1 1 1 Notes 1 100, 125 and 200A convertible base unit catalog numbers include interior, box and cover only. Main devices and accessories must be ordered separately for field installation. All convertible base units are listed as suitable for use as service entrance equipment when used per Article 384 of the NEC. 2 Ground bar kits priced separately, refer to Page V1-T1-65. 3 All main circuit breaker loadcenters are listed for use as service entrance equipment and are shipped with a neutral bonding strap preattached. The maximum main rating of the loadcenter is the main breaker rating when used as service entrance equipment. 4 Interrupting rating depends on main circuit breaker selected. See Page V1-T1-65 for mains. 5 For main breaker, use Type BW or CSR. For main lug, use Type BRL. 6 Rainproof loadcenters are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-65. 7 Hold-down screw BREQS125 comes with loadcenter for back-fed Types BR and BRH main circuit breakers. 8 For main breaker, use Type BR. For main lug, use Type BRSF. 9 Suitable for use as service equipment when not more than six main disconnecting means are provided and when not used as a lighting and appliance panelboard. (see Article 408.34 of the NEC). 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-53 1.2 1 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Three-Phase—Type BR Main Circuit Breaker Loadcenters Three-Phase, Four-Wire—Main Lug Loadcenters—Copper Bus—208Y/120 Vac or 240 Vac, Insulated/Bondable Split Neutral 1 1 Main Ampere Rating Maximum Number 1-Inch (25.4 mm) Enclosure Type Box Size Wire Size Range Cu/Al 60°C or 75°C for Main Loadcenter Catalog Number (With Combination or NEMA Type 3R Cover) Spaces Circuits 125 12 24 Indoor C1 #6–3/0 3BR1224LC125 125 12 24 Outdoor C1R #6–3/0 3BR1224LC125R 150 24 42 Indoor D1 #4–300 kcmil 3BR2442LC150 150 24 42 Outdoor D1R #4–300 kcmil 3BR2442LC150R 200 12 24 Indoor C4 #4–300 kcmil 3BR1224LC200 200 12 24 Outdoor C3R #4–300 kcmil 3BR1224LC200R 200 30 42 Indoor G1 #4–300 kcmil 3BR3042LC200 200 30 42 Outdoor G1R #4–300 kcmil 3BR3042LC200R 1 200 42 42 Indoor L1 #4–300 kcmil 3BR4242LC200 200 42 42 Outdoor L1R #4–300 kcmil 3BR4242LC200R 1 225 30 42 Indoor L1 #4–300 kcmil 3BR3042LC225 225 30 42 Outdoor L1R #4–300 kcmil 3BR3042LC225R 1 1 1 1 1 Three-Phase, Four-Wire—Main Circuit Breaker Loadcenters—Copper Bus—208Y/120 Vac or 240 Vac, Insulated/Bondable Split Neutral 1 1 1 1 1 1 Wire Size Range Cu/Al 60°C or 75°C for Main Breaker Loadcenter Catalog Number (With Combination or NEMA Type 3R Cover) 24 Indoor C1 #14–1/0 3BR1224BC100 24 Outdoor C1R #14–1/0 3BR1224BC100R 30 42 Indoor L1 #6–4/0 3BR3042BC150 150 30 42 Outdoor L1R #6–4/0 3BR3042BC150R 200 42 42 Indoor L2 2/0–300 kcmil 3BR4242BC200 200 42 42 Outdoor L2R 2/0–300 kcmil 3BR4242BC200R 225 42 42 Indoor L2 2/0–300 kcmil 3BR4242BC225 225 42 42 Outdoor L2R 2/0–300 kcmil 3BR4242BC225R Spaces 12 100 12 CC 10 kAIC 150 Three-Phase, Four-Wire—Main Circuit Breaker Loadcenters—Aluminum Bus—208Y/120 Vac or 240 Vac Insulated/Bondable Split Neutral 1 1 Wire Size Range Cu/Al 60°C or 75°C for Main Breaker Loadcenter Catalog Number 12 (With Combination or NEMA Type 3R Cover) 24 Indoor C1 #14–1/0 3BR1224B100 24 Outdoor C1R 30 42 Indoor L1 #6–4/0 3BR3042B125 30 42 Indoor L1 #6–4/0 3BR3042B150 30 42 Outdoor L1R 30 42 Indoor L1 30 42 Outdoor L1R Spaces 12 12 CC 10 kAIC 125 150 1 1 Box Size 100 200 1 Circuits Enclosure Type BR 10 kAIC 1 1 Maximum Number 1-Inch (25.4 mm) Main Ampere Rating Main Breaker Type 1 Box Size 100 1 3BR4242B200 Circuits Enclosure Type BR 10 kAIC 1 1 Maximum Number 1-Inch (25.4 mm) Main Ampere Rating Main Breaker Type 3BR1224B100R 3 3BR3042B150R 3 #1–250 kcmil 3BR3042B200 3BR3042B200R 3 42 42 Indoor L2 3BR4242B200 42 42 Outdoor L2R 3BR4242B200R 3 L2 2/0–300 kcmil 3BR4242H200 6 2/0–300 kcmil 3BR4242B225 CHH 100 kAIC 200 42 42 Indoor CC 10 kAIC 225 42 42 Indoor L2 42 42 Outdoor L2R DK 4 22 kAIC 400 42 42 Indoor 24 42 42 Outdoor 47 LD 5 600 42 42 Indoor 24 3BR4242B225R 3 (2) #3/0–250 kcmil 3B4242DFN 3B4242DR1N 3 (2) #3/0–500 kcmil 3B4242EFN Notes 1 All main circuit breaker loadcenters are listed for use as service entrance equipment and are shipped with a neutral bonding strap pre-attached (commercial loadcenters do not have a pre-attached bonding strip). The maximum main rating of the panel is the main circuit breaker rating when used as service entrance equipment. 2 Ground bar kits priced separately. See Page V1-T1-65. 3 Rainproof loadcenters are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-65. 4 Type DK main circuit breaker is rated 65 kAIC at 240 Vac and allows a 22 kAIC series rating on the loadcenter when Types BR, BD and BJ branch circuit breakers are used. 5 The LD main circuit breaker is rated 65 kAIC at 240 Vac. Type LD circuit breaker is not series rated with Types BR, BD and BJ branch circuit breakers. 6 Includes CHH 100 kAIC rated MCB. 100 kAIC series rating combination is obtained when types BD, BR, BQ, BQC and GFGB branch breakers are used with CHH main. 1 1 1 V1-T1-54 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers 3BR1224L125 Three-Phase, Four-Wire—Main Lug Loadcenters—Aluminum Bus—208Y/120 Vac or 240 Vac, Insulated/Bondable (Unless Otherwise Noted) Main Ampere Rating 100 125 150 200 225 34242DFN 1.2 Maximum Number 1-Inch (25.4 mm) 1 Box Size Wire Size Range Cu/Al 60°C or 75°C for Main Lugs Loadcenter Catalog Number (With Combination or NEMA Type 3R Cover) #6–1/0 3BR3L100S 23 Spaces Circuits Enclosure Type 3 3 Indoor 9 3 3 Outdoor 9R 12 24 Indoor C1 12 24 Outdoor C1R 18 36 Indoor C2 18 36 Outdoor C3R 24 42 Indoor D1 24 42 Outdoor D1R 12 24 Indoor C4 12 24 Outdoor C3R 18 36 Indoor C4 18 36 Outdoor C3R 30 42 Indoor G1 30 42 Outdoor G1R 42 42 Indoor L1 42 42 Outdoor L1R 42 42 Indoor L1 42 42 Outdoor L1R 1 1 3BR3L100R 34 #6–3/0 1 3BR1224L125 56 3BR1224L125R 456 #6–4/0 1 3BR1836L150 3BR1836L150R #4–300 kcmil 1 3BR2442L150 3BR2442L150R 4 #4–300 kcmil 1 3BR1224L200 6 3BR1224L200R 46 #4–300 kcmil 1 3BR1836L200 3BR1836L200R #4–300 kcmil 1 3BR3042L200 3BR3042L200R 4 #4–300 kcmil 1 3BR4242L200 3BR4242L200R 4 #4–300 kcmil 1 3BR4242L225 3BR4242L225R 4 1 Three-Phase, Four-Wire—Main Lug Loadcenters—Aluminum Bus—208Y/120 Vac or 240 Vac, Insulated/Bondable Split Neutral Maximum Number 1-Inch (25.4 mm) Main Ampere Rating 400 600 Spaces Circuits Enclosure Type Box Size Wire Size Range Cu/Al 60°C or 75°C for Main Lugs 1 Commercial Loadcenter Catalog Number g With Flush or NEMA Type 3R Cover 1 With Surface Cover 42 42 Indoor 22 34242DSN 42 Outdoor 46 (1) 250–750 kcmil or (2) #3/0–250 kcmil 34242DFN 42 34242DR1N 4 — 42 42 Indoor 22 (2) #2–500 kcmil — 34242ESN Notes 1 Ground bar kits priced separately. See Page V1-T1-65. 2 Surface cover only. 3 Insulated/bondable single neutral. 4 Rainproof loadcenters are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-65. 5 Has notch for BREQS125 hold-down kit. 6 Suitable for use as service equipment when not more than six main disconnecting means are provided and when not used as a lighting and appliance panelboard (see Article 408.34 of the NEC). g Door lock and key included with loadcenter. 1 1 1 1 1 1 1 1 Box sizes Pages V1-T1-66 through V1-T1-69. 1 1 1 1 1 1 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-55 1.2 1 3BR3030N100 1 1 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Three-Phase, Four-Wire—Convertible Loadcenters—Aluminum Bus—208Y/120 Vac or 240 Vac, Insulated/Bondable Split Neutral Spaces 100 4 30 3BR4242N225NY 1 1 Wire Size Range Cu/Al 60°C or 75°C for Main Loadcenter Catalog Number 23 (With Combination or NEMA Type 3R Cover) See main breaker and main lug kit tables below. 3BR3030N100 5 Circuits Enclosure Type Box Size 30 Indoor D1 30 30 Outdoor D1R 3BR3030N100R 56 12 24 Indoor C1 3BR1224N125 567 12 24 Outdoor C1R 3BR1224N125R 5678 200 30 42 Indoor L1 3BR3042N200 225 42 42 Indoor L2 3BR4242N225 42 42 Indoor B 3BR4242B225NY 9 1 1 Maximum Number 1-Inch (25.4 mm) Main Ampere Rating 1 125 4 1 1 1 1 1 Three-Phase Main Breaker Kits—10 kAIC 1 Ampere Rating Wire Size Range Cu/Al 60°C or 75°C Catalog Number 1 100 #6–4/0 CC3100N 125 #6–4/0 1 1 1 Three-Phase Main Lugs Kit for Convertible Loadcenters Ampere Rating Wire Size Range Cu/Al 60°C or 75°C Catalog Number CC3125N 225 #1–300 kcmil 3BRL225 225 #1–300 kcmil 3BRS225 j 150 #6–4/0 CC3150N 175 #2/0–300 kcmil CC3175N 200 #2/0–300 kcmil CC3200N 225 #2/0–300 kcmil CC3225N Notes 1 The maximum rating of the loadcenter is the main circuit breaker rating when used as service entrance equipment. 2 100, 125 and 200A convertible base unit catalog numbers include interior, box and cover only. Main devices and accessories must be ordered separately for field installation. All convertible base units are listed as suitable for use as service entrance equipment when used per Article 384 of the NEC. 3 Ground bar kits priced separately. See Page V1-T1-65. 4 For main breaker, use Type BR. For main lug, use Type BRSF. 5 BREQS125 hold-down screw comes with loadcenter for back-fed Types BR and BRH main circuit breakers. 6 Rainproof loadcenters are furnished with hub closure plates. For rainproof hubs, refer to Page V1-T1-65. 7 Convertible to maximum of 100A main circuit breaker and 125A main lug. 8 Suitable for use as service equipment when not more than six main disconnecting means are provided and when not used as a lighting and appliance panelboard (see Article 408.34 of the NEC). 9 Order 3BR42FTNY or 3BR42STNY cover separately. j For subfeed. 1 1 1 1 1 1 1 1 1 Box sizes Pages V1-T1-66 through V1-T1-69. 1 1 1 1 V1-T1-56 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers 1.2 Contents—BR Specialty Products Spa Panels Description Page Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BR Specialty Products Spa Panels Riser Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type BR Renovation Loadcenter . . . . . . . . . . . Type BR Mechanical Interlock Kits . . . . . . . . . . Type BR Retrofit Interior Kits . . . . . . . . . . . . . . BR Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-42 1 1 1 V1-T1-58 V1-T1-59 V1-T1-61 V1-T1-72 V1-T1-75 1 1 1 1 1 1 1 BR Specialty Products 1 Spa Panels 1 Product Description Features Eaton’s BR Spa Panels distribute power to outdoor loads and provide protection for people from electric shock. Save time and money with streamlined installation procedures and easy-access features. Spa panels meet NEC requirements by providing a ground fault circuit interruption device and a disconnect switch in a single simple device. Ships assembled prewired, factory tested and ready to install. ● ● ● 1 10-year warranty UL Listed Factory-installed two-pole ground fault circuit interrupter (GFCI) 1 1 1 1 Product Selection BR Spa Panel 1 Spa Panel—Meets NEC Article 680.40 Through 680.43— Requirements for GFCI Protection Main Ampere Rating Maximum Number 1-Inch (25.4 mm) Space 40 50 Poles Enclosure Type Box Size Wire Size Range Cu/Al 60°C or 75°C for Main Lugs Catalog Number — — Outdoor 5R #8–#2 BR40SPA 1 — — Outdoor 5R #8–#2 BR50SPA 2 1 1 1 1 Notes 1 Includes a GFCB240 breaker, factory installed. 2 Includes a GFCB250 breaker, factory installed. 1 1 1 1 1 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-57 1.2 1 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Contents—BR Specialty Products Riser Panel Description 1 Page Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BR Specialty Products Spa Panels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Riser Panel Type BR Renovation Loadcenter . . . . . . . . . . . . Type BR Retrofit Interior Kits. . . . . . . . . . . . . . . BR Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . 1 1 1 V1-T1-42 V1-T1-57 V1-T1-59 V1-T1-72 V1-T1-75 1 1 1 1 1 1 Riser Panel 1 Product Description 1 1 1 1 1 1 Eaton’s Riser Panel is a loadcenter with an offset interior to allow riser cables to pass through the enlarged gutter. By using lay-in tap lugs, the contractor is able to simply strip off a length of the riser cable’s insulation, and tap off to the riser panel’s main lugs. These panels are used in the construction of assisted living homes, dormitories, public housing complexes and apartments. 1 Product Selection BR1224L125RIS Main Ampere Rating BRGUTTER (Shown with Loadcenter) 1 Riser Panel Maximum Number 1-Inch (25.4 mm) Space Circuits Enclosure Type Box Size 12 24 Indoor C4 #6–2/0 BR1224L125RIS 125 12 24 Indoor C4 #6–2/0 BR1224L125RISBP 1 125 20 24 Indoor C4 #6–2/0 BR2024L125RIS 125 20 24 Indoor C4 #6–2/0 BR2024L125RISBP 1 125 20 30 Indoor C2 #6–2/0 BR2030L125RIS 200 30 40 Indoor D1 #1–300 BR3040L200RIS Riser Panel Accessories Catalog Number GTAP250 1 1 Notes 1 Bulk-packaged loadcenter without carton. Must be ordered in multiples of 16. 2 Refer to Page V1-T1-67 for dimensions. BRGUTTER is box size C2. 1 1 1 Accessories 1 For riser panels not shown, contact the Flex Center at 1-800-330-6479 for both CH and BR riser panels. 1 1 1 V1-T1-58 Catalog Number 125 BRGUTTER 2 1 Wire Size Range Cu/Al 60°C or 75°C for Main Lugs Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers 1.2 Contents—BR Specialty Products BR Renovation Loadcenters Description Page Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BR Specialty Products Spa Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . Riser Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type BR Renovation Loadcenter Options and Accessories . . . . . . . . . . . . . . Type BR Retrofit Interior Kits . . . . . . . . . . . . . . BR Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-42 V1-T1-57 V1-T1-58 V1-T1-60 V1-T1-72 V1-T1-75 1 1 1 1 1 1 1 1 1 1 1 Type BR Renovation Loadcenter Product Description ● ● ● ● ● Available in 10, 20, 30 and 40 circuit main breaker styles Designed to replace existing loadcenters and fuse boxes Type BR loadcenter packaged with circuit breakers Factory-installed 5-circuit terminal block(s) Twin-stacked neutral design Features, Benefits and Functions Quick-Pro All you need to know to save time and make more money. Specified on certain Eaton products, the Quick-Pro symbol allows for immediate recognition of products that are designed for straightforward installation. When you see Quick-Pro, you know you can install quickly—sometimes up to 50% less than the usual installation time—and move on to your next job. SM ● ● Factory-installed terminal block(s) allows installer to terminate existing short wires without using wire nuts or junction boxes Twin-stacked neutrals are mounted up high in the loadcenter, which allows for all neutral and ground wires to be terminated in the top half of the loadcenter ● ● ● Specifically designed for the service contractor— this is the ONLY renovation line in the industry Single-pole and two-pole breakers included 10-year warranty on loadcenter and breakers 1 1 1 1 1 1 1 1 1 Product Selection BR2020B100RN 1 1 BR Value Packs 1 Main Breaker Type Description BR 10 kAIC Single-phase 100A 10k main breaker 10/20 circuit surface-mount box is 11.75" wide x 13" tall CSR 25 kAIC 1 Wire Size Range Number of 5-Circuit Terminal Blocks Single-Pole Breakers Two-Pole Breakers Catalog Number #6–1/0 0 (2) BR115 (1) BR230 BR1020B100SRNV 1 Single-phase 100A 10k main breaker 10/20 circuit flush-mount box is 11.75" wide x 13" tall 0 (2) BR115 (1) BR230 BR1020B100FRNV 1 Single-phase 100A 10 kAIC main breaker 20/20 circuit 1 (5) BR120 (1) BR230 BR2020B100RNV8 1 2 (5) BR115 (5) BR120 (1) BR230 (1) BR250 BR3040B100RNV4 1 Single-phase 200A 25 kAIC main breaker 30/40 circuit #2–300 kcmil 1 Note 1 Indoor enclosure type. 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-59 1.2 1 1 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Options and Accessories BRSF125 Field Installation Kits and Parts 1 Number of Poles 1 Main and Sub-Feed Lug Blocks 1 2 3BRS225 1 3 1 1 Wire Size Range Cu/Al 60°C or 75°C Ordering Quantity 1 Catalog Number 125 2 #8–2/0 1 BRSF125 150 2 #8–2/0 1 BRSF150 2 225 4 #2–300 kcmil 1 BRS225 150 3 #8–2/0 1 3BRSF150 2 225 6 #2–300 kcmil 1 3BRS225 Main Lugs BRL200 1 1 1 Number of 1-Inch (25.4 mm) Spaces Needed Ampere Rating Two-pole, 200A stud mounted (includes deadfront filler plate) #1–300 kcmil 1 BRL200 Neutral/ground lug Add-on neutral or ground lug #2/0 maximum 1 NL20 #3/0 maximum 1 NL30 300 kcmil maximum 1 NL300 Filler Plates TDL 1-inch (25.4 mm) circuit breaker space 25 BRFP BW main circuit breaker space (with hardware) 1 BWFP 1 Door lock —12–42 circuits, and 100–225A 1 TDL 1 Door lock—4–8 circuits, 125A 1 CH9FL ANSI-61 light gray touchup paint for current loadcenters 1 SPC61 Isolated neutral assembly (computer circuits) 1 BINA Circuit directory—adhesive backed 10 TCD 1 1 1 1 1 Cover screws 25 LCCS Cover replacement latch (gray) 14-5/16 (363.5 mm) wide loadcenters only 1 BRRL Circuit marking strip (next to breaker) 10 BRMS Circuit identification label (preprinted breaker labels) 25 CHBL Series rated caution label 25 SRL Bonding strip with screw 1 BSSUSE Notes 1 Must be purchased in multiples of ordering quantities indicated. 2 #8–2/0 wire size range is 75°C rated only. 1 1 1 1 1 1 1 1 1 1 1 1 V1-T1-60 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers 1.2 Contents Type BR Mechanical Interlock Kits Description Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BR Specialty Products Spa Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . Riser Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type BR Renovation Loadcenter . . . . . . . . . . . Type BR Retrofit Interior Kits . . . . . . . . . . . . . . Type BR Mechanical Interlock Kits BR Circuit Breakers Product Selection . . . . . . . . . . . . . . . . . . . . . . . Circuit Breaker Accessories . . . . . . . . . . . . . . . Wiring Diagrams. . . . . . . . . . . . . . . . . . . . . . . . Page V1-T1-42 V1-T1-57 V1-T1-58 V1-T1-59 V1-T1-72 V1-T1-76 V1-T1-84 V1-T1-86 1 1 1 1 1 1 1 1 1 Type BR Loadcenter with Mechanical Interlock Kit 1 1 Type BR Mechanical Interlock Kits Product Description Features and Benefits With the aging electrical infrastructure and frequent severe storms, power outages are becoming more and more frequent, affecting thousands of people nationwide. Eaton mechanical interlock kit provides an easy and cost-effective solution when using backup emergency power. ● This solution expands the robust line of emergency power products and accessories. ● ● ● ● Prevents utility and generator supplies from being on at the same time Protects utility linemen from dangerous generator backfeed Robust interlock design Offered in two unique styles for almost any BR loadcenter, which can reduce inventory levels Quick and easy installation—drill points or fixtures for pilot holes are provided on all applicable BR loadcenters; no additional assembly is required 1 Standards and Certifications ● ● UL 67 Listed—For use with BR loadcenters Meets NEC® Article 702 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-61 1.2 1 1 Type BR Loadcenters and Circuit Breakers Product Selection Each mechanical interlock kit includes: ● 1 ● 1 ● ● Interlock assembly Hold down kit 1 New labels Necessary screws 1 Warranty information: ● ● 10-year warranty on all Type BR circuit breakers and loadcenters Refer to Eaton for complete warranty details Mechanical Interlock Kits 2 1 1 Loadcenters and Circuit Breakers Description BRMIKBR Catalog Number Single BRMIKBR Bulk pack 3 BRMIKBRBP Single BRMIKCSR Bulk pack 3 BRMIKCSRBP 1 1 1 BRMIKCSR 1 1 1 1 1 Notes 1 For breakers under 70A used in backfed applications, add “B” to the end of the catalog string to get the appropriate “hold-down” version. 2 Clamshell packaged. 3 Bulk pack contains 10 units, individually packaged. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V1-T1-62 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers 1.2 Mechanical Interlock Cover Covers mechanically interlock two breakers—Type BW or CSR main breaker with a Type BR branch breaker. BR816B100 1 1 1 1 Mechanical Interlock Cover Fits Loadcenter Catalog Numbers Mechanical Interlock Trim/Deadfront Catalog Numbers Mechanical Interlock Kit Catalog Numbers BRCOVC10M BRMIKBR 1 1 Indoor BR816B100 1 BR816N100 BR1212B100 1 BRCOVC12M BR1220B100 1 BR1220H100 BR1224N125 BRCOVC13M BR1616B100 BRCOVC16M 1 1 BR1620B100 BR1624B100 BR1624B125 BRCOVC17M 1 BRCOVC22M 1 BR1624N125 BR2020B100, BR2020BC100 BR2020H100, BR2020HC100 1 BR2024H100 BR2020HC100 1 BR2030B100 1 BR2040B100 BR2024B125 BRCOVC23M 1 BR2024N125, BR2024NC125 BR3030B100, BR3030BC100 BRCOVC59M 1 BR3030H100, BR3030HC100 Raintight BR1020B100R BR3RDF1M BR1224B100R 1 Field-installed interlock kits not available for these catalog numbers. 1 BR1224N125R, BR1224NC125R BR1624B100R BR3RDF2M 1 BR3RDF4M 1 BR1624N125R BR2024B100R, BR2024B125R 1 BR2024N125R, BR2024NC125R 1 1 1 1 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-63 1.2 1 BR4040B200 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Mechanical Interlock Cover, continued 1 Fits Loadcenter Catalog Numbers 1 Indoor 1 BR1224N200 1 BR1632N200 BR1630B150 Mechanical Interlock Trim/Deadfront Catalog Numbers Mechanical Interlock Kit Catalog Numbers BRCOV16C4FM BRMIKCSR BR1632B200 1 BR2030B150 1 BR2040B150 BRCOV20C4FM BR2030H150 BR2040B200, BR2040BC200 1 BR2040H200 1 BR2430B150, BR2430BC150 BRCOV20D1FM BR2040N200, BR2040NC200 1 BR3030B150 1 BR3040B150 BRCOV30G1FM BR3030H150 BR2440B200 1 BR2440N200 1 BR3040N200, BR3040NC200 BR3040B200, BR3040BC200 1 BR3040H200 1 BR4040H200 BR4040B200, BR4040BC200 BRCOV40L1FM BR4040N200, BR4040NC200 1 BR4242B225 1 Raintight 1 BR816B200RF 1 BR1224N200R 1 BR2040B150R BR816B150RF BRCOV42L2FM BR3RDF5M 1 BR816N200RF BR2030B150R 1 BR2040B200R 1 BR2040N200R BR3RDF11M 1 BR2040B225R BR3030B150R 1 BR3040B200R 1 BR4040B200R BR3RDF12M 1 BR3040N200R BR3RDF13M 1 1 BR4040N200R BR48B200RF BR3RDF14M 1 BR4242B225R BR3RDF15M 1 Mechanical Interlock Loadcenter Replacement Covers 2 1 BR2020B100M, BR2020BC100M 1 BR2024H100M BR3030BC100M 1 Notes 1 Deadfront only. 2 Can only be provided as replacement covers for factory-installed mechanically interlock loadcenters. 1 V1-T1-64 BRCOV20C2FM Field-installed interlock kits not available for these catalog numbers. BRCOV30D1FM Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers DS300H2 1.2 Field Installation Rainproof Conduit Hubs Conduit Size Inches (mm) Ordering Quantity 1 Catalog Number 0.75 (19.1) 1 DS075H1 1.00 (25.4) 1 DS100H1 1.25 (31.8) 1 DS125H1 1.50 (38.1) 1 DS150H1 2.00 (50.8) 1 DS200H1 Group 2—for use with 150, 200 and 225A MLO and MCB loadcenters and circuit breaker enclosures except for 2.00 (50.8) the following 200A loadcenters: BR48B200RF. Also for use with 400 and 600A loadcenters and New York City 2.50 (63.5) loadcenters manufactured after November 1, 2005 3.00 (76.2) 1 DS200H2 1 DS250H2 1 DS300H2 Description Group 1—for use with 70, 100 and 125A MLO and MCB loadcenters and circuit breaker enclosures and the following 150 and 200A panels: BR48B200RF Type H conduit hubs for loadcenters PL0724R and S3100RN Adapter kit—Allows Installing a Group 1 hub on devices arranged for Group 2 hubs 0.75 (19.1) 1 RH75P 1.00 (25.4) 1 RH100P 1.25 (31.8) 1 RH125P 1.50 (38.1) 1 RH150P — 1 DS900AP Group 1 small blank hub plate with bump — 1 DS900CP1 Group 2 Large blank hub plate with bump — 1 DS900CP2 1 1 1 1 1 1 1 1 1 1 1 GBK14 1 Ground Bar Kits Ordering Quantity 1 Catalog Number dssssds 2.54 (64.5) 1 GBK5 2 dssssdsj 3.59 (91.2) Description (See Legend) Length Inches (mm) BRGBK39512 GBK520 2 1 GBK10 2 dssssdssssssj 5.34 (135.6) 1 GBK1020 2 4.61 (117.1) 1 GBK13 2 dssssdssssssssss 5.69 (144.5) 1 GBK14 2 dssssdssssssssssj 6.74 (171.2) 1 GBK1420 2 dssssdsssssssssssssssss 8.14 (206.8) 1 GBK21 2 dssssdsssssssssssssssssj 9.19 (233.4) 1 GBK2120 2 5.78 (146.8) 1 BRGBK39512 34 1 GB4NM 5 f k f d f k f f f k f d f k f f f k f f d f f f k f d f k f f f 1 dssssdssssss 4.29 (109.0) sssss 1.84 (46.7) 1 1 1 1 1 1 1 1 Ground Bar Legend s (3) #14–10 Cu/Al or (1) #14–4 Cu/Al j (1) #6–2/0 Cu/Al (1) #14–1/0 Cu/Al or (3) #14–10 Cu/Al (1) #14–6 Cu/Al or (2) #14–12 Cu/Al d Mounting Hole fk 1 1 1 Notes 1 Must be purchased in multiples of ordering quantities indicated. 2 Distance between mounting holes is 1.75 inches (44.5 mm). 3 For single- and three-phase 400 and 600A applications. 4 Distance between mounting holes is 2.34 inches (59.5 mm). 5 For non-metallic enclosures. Snaps into molded base. 1 1 1 1 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-65 1.2 1 1 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Dimensions Approximate Dimensions in Inches (mm) Residential/Commercial/New York City Loadcenters, Unit Enclosures—Box Sizes 1 Note: Box sizes do not include covers/fronts. 1 Residential Loadcenters—NEMA Type 1 Indoor Commercial Loadcenters—NEMA Type 1 Indoor Box Size Height Width Depth Box Size Height Width Depth 1 A1 15.00 (381.0) 11.25 (285.8) 3.75 (95.3) 19 44.00 (1117.6) 16.16 (410.4) 6.25 (158.8) 1 B1 16.75 (425.5) 14.31 (363.5) 3.88 (98.4) 20 44.00 (1117.6) 16.16 (410.4) 6.25 (158.8) B2 18.75 (476.3) 14.31 (363.5) 3.88 (98.4) 22 54.00 (1371.6) 16.22 (412.0) 6.31 (160.3) 1 C1 21.00 (533.4) 14.31 (363.5) 3.88 (98.4) 24 66.50 (1689.1) 16.22 (412.0) 6.31 (160.3) C2 23.00 (584.2) 14.31 (363.5) 3.88 (98.4) 1 C4 27.00 (685.8) 14.31 (363.5) 3.88 (98.4) D1 29.13 (739.8) 14.31 (363.5) 3.88 (98.4) 1 G1 34.13 (866.8) 14.31 (363.5) 3.88 (98.4) 1 L1 39.00 (990.6) 14.31 (363.5) 3.88 (98.4) L2 45.00 (1143.0) 14.31 (363.5) 3.88 (98.4) 1 2 3 9.44 (239.7) 4.50 (114.3) 3.00 (76.2) 1 4 13.00 (330.2) 11.00 (279.4) 3.56 (90.5) 5 9.44 (239.7) 4.50 (114.3) 3.00 (76.2) 6 12.00 (304.8) 6.88 (174.6) 4.50 (114.3) 7 13.00 (330.2) 11.00 (279.4) 3.56 (90.5) 9 14.50 (368.3) 6.50 (165.1) 3.50 (88.9) 1 1 8.63 (219.1) 5.00 (127.0) 3.50 (88.9) 1 1 Commercial Loadcenters—NEMA Type 3R Outdoor Box Size Height Width Depth 42 38.00 (965.2) 16.31 (414.3) 6.38 (161.9) 43 44.00 (1117.6) 16.31 (414.3) 6.38 (161.9) 46 54.00 (1371.6) 16.31 (414.3) 6.38 (161.9) 47 66.56 (1690.7) 16.31 (414.3) 6.38 (161.9) New York City Loadcenters—NEMA Type 1 Indoor Box Size Height Width Depth A 38.00 (965.2) 18.13 (460.4) 5.00 (127.0) B 44.00 (1117.6) 18.13 (460.4) 5.00 (127.0) C 66.50 (1689.1) 18.13 (460.4) 6.25 (158.8) Residential Loadcenters—NEMA Type 3R Outdoor Box Size Height Width Depth Types ECB and ECC Unit Enclosures—NEMA Type 1 Indoor B1R 16.75 (425.5) 14.31 (363.5) 5.19 (131.8) Height Width Depth B2R 18.75 (476.3) 14.31 (363.5) 5.19 (131.8) 1 23.25 (590.6) 8.88 (225.4) 4.50 (114.3) C3R 25.00 (635.0) 14.31 (363.5) 5.19 (131.8) 1 D1R 29.13 (739.8) 14.31 (363.5) 5.19 (131.8) G1R 34.13 (866.8) 14.31 (363.5) 5.19 (131.8) 1 1 L1R 39.00 (990.6) 14.31 (363.5) 5.19 (131.8) L2R 45.00 (1143.0) 14.31 (363.5) 5.19 (131.8) 1 2R 8.63 (219.1) 1 3R 9.44 (239.7) 4.50 (114.3) 3.00 (76.2) 4R 13.00 (330.2) 11.00 (279.4) 3.56 (90.5) 1 5R 9.44 (239.7) 4.50 (114.3) 3.00 (76.2) 6R 11.75 (298.5) 6.50 (165.1) 4.50 (114.3) 1 7R 13.00 (330.2) 11.00 (279.4) 3.56 (90.5) 8R 27.00 (685.8) 10.50 (266.7) 4.75 (120.7) 9R 14.25 (362.0) 6.50 (165.1) 4.00 (101.6) C1R 21.00 (533.4) 14.31 (363.5) 5.19 (131.8) 1 1 5.00 (127.0) 3.50 (88.9) Types ECB and ECC Unit Enclosures—NEMA Type 3R Outdoor Height Width Depth 23.68 (601.7) 9.31 (236.5) 5.44 (138.1) 1 1 1 1 V1-T1-66 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers 1.2 Approximate Dimensions in Inches (mm) 1 Residential Loadcenter Knockouts Knockouts for Box Sizes A1, B1, B2, C1, C2, C4, D1, G1, L1, L2, B1R, B2R, C1R, C3R, D1R, G1R, L1R, L2R Code Diameter A 0.50 (12.7) 0.75 (19.1) — — — B 0.50 (12.7) — — — — C 0.50 (12.7) 1.25 (31.8) 1.50 (38.1) 2.00 (50.8) 2.50 (63.5) D 1.25 (31.8) 1.25 (31.8) 2.00 (50.8) 2.50 (63.5) — E 0.50 (12.7) 0.75 (19.1) 1.00 (25.4) — — F 0.50 (12.7) 0.75 (19.1) 1.00 (25.4) 1.50 (38.1) 2.00 (50.8) G 1.25 (31.8) 1.50 (38.1) 2.00 (50.8) — — H 0.50 (12.7) 0.75 (19.1) 1.00 (25.4) 1.25 (31.8) 1.50 (38.1) 2.06 (52.3) Dia. (125A Max.) 3.06 (77.7) Dia. (225A Max.) 1.00 (25.4) 1.25 (31.8) 1.50 (38.1) 2.00 (50.8) 2.50 (63.5) 1.00 (25.4) 1.25 (31.8) 1.50 (38.1) — — 1 1 1 D E B E E 1 .45 (11.4) Dia. KO A B B B B B B A 1 D D E .45 (11.4) Dia. KO J 1 Hub D I 1 Residential NEMA Type 1 Indoor and NEMA Type 3R Outdoor Enclosures B B B H B B I A A 1 Outdoor Boxes B1R, B2R, C1R, C3R, D1R, G1R, L1R, L2R B B J B J B B 1 B E A B B 1 J A 1 A B B B B B 1 B B B J A E J J J B B B E B J B B 1 B A B 1 Indoor Boxes A1 B A H A D B B B I B B B B E E B B A A B 1 E D D 1 D E A B B A B 1 .45 (11.4) Dia. KO .45 (11.4) Dia. KO E A B A B A 1 B A E E D D D .45 (11.4) Dia. KO A A B B E B B B B I 1 A H B B B B 1 D .45 (11.4) Dia. KO B A Indoor Boxes B1, B2 .45 (11.4) Dia. KO B A H A D D B B B I B B 1 1 .45 (11.4) Dia. KO B B B E E B A A B E 1 D D E A B B A E A B A B 1 B A B A E A B B A E 1 D 1 D D D .45 (11.4) Dia. KO .45 (11.4) Dia. KO A A B B E B B B B B B I A H B B B 1 A Indoor Boxes C1, C2, C4, D1, G1, L1, L2 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-67 1.2 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers 1 Approximate Dimensions in Inches (mm) 1 Knockouts for Box Sizes 3, 4, 5, 6, 7, 9, 2R, 3R, 4R, 5R, 6R, 7R, 8R, 9R 1 Code Diameter A 0.50 (12.7) — — — 1 B 0.50 (12.7) 0.75 (19.1) — — 1 C 0.50 (12.7) 0.75 (19.1) 1.00 (25.4) — D 0.50 (12.7) 0.75 (19.1) 1.00 (25.4) 1.25 (31.8) 1 E 0.75 (19.1) 1.00 (25.4) 1.25 (31.8) — F 0.75 (19.1) 1.00 (25.4) 1.25 (31.8) 1.50 (38.1) 1 G 1.00 (25.4) 1.25 (31.8) 1.50 (38.1) — H 1.00 (25.4) 1.25 (31.8) 1.50 (38.1) 2.00 (50.8) I 1.25 (31.8) 1.50 (38.1) 2.00 (50.8) — 1 1 1 1 Residential NEMA Type 1 Indoor and NEMA Type 3R Outdoor Enclosures Mounting Hole for 5/16 (7.9) Screw 1 F A Hub A A E 2.38 (60.3) A A A E A C C A G D Box 3R B Hub A B B A Box 4 B H A Hub A C F A G D G A A A D A A A G B D A B C A A A G A G D D A F B B D F A Box 5 Box 4R 1 1 B G A A A F F A 1 1 A A A D D A A A A A F A F Hub D G Box 3 1 1 B B A A F 1 A A A A Box 2, 2R 1 B B A G G D .50–.75–1.00 (12.7–19.1–25.4) .50–1.00–1.25 (12.7–25.4–31.8) D B 1 1 G A .31 (7.9) 1 1 B A A A .50–.75 (12.7–19.1) 6.38 (161.9) 1 1.00–1.25 KO (25.4–31.8) KO R D A B Hub Hub C A A A B C F A A A G A Box 7 1 B B C C G G F C A A A B C G G I C I C A A A A Box 7R B B B I A A A A B C Box 8R B H B Hub G G A G B B B B B G G G A C B D B Box 6R A A Box 9 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com G G A G G A C G B 1 V1-T1-68 F B B B D A H C G C A F Box 6 A B B C Box 5R A A A A G F F A B C B A B B G B B C A Box 9R 1.2 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Approximate Dimensions in Inches (mm) 1 Commercial Loadcenter Knockouts NEMA Type 1 Indoor Commercial Enclosures Knockouts for Box Sizes 19, 20, 22, 24 1 Indoor Commercial Enclosures Code Diameter A 0.50 (12.7) — — B 0.50 (12.7) 0.75 (19.1) — — C 0.75 (19.1) 1.00 (25.4) 1.50 (38.1) — D 1.50 (38.1) 2.00 (50.8) 2.50 (63.5) 3.00 (76.2) E 2.00 (50.8) 2.50 (63.5) 3.00 (76.2) — F 2.50 (63.5) 3.00 (76.2) 3.50 (88.9) — A B B B B B H E C 1 A B B B B B H E 1 C — 1 1 1 1 NEMA Type 3R Outdoor Commercial Enclosures Knockouts for Box Sizes 42, 43, 46, 47 1 Code Diameter A 0.50 (12.7) — — — B 0.50 (12.7) 0.75 (19.1) — — C 0.75 (19.1) 1.00 (25.4) 1.25 (31.8) — D 1.50 (38.1) 2.00 (50.8) 2.50 (63.5) — E 2.00 (50.8) 2.50 (63.5) 3.00 (76.2) — 1 D D A F 2.50 (63.5) 3.00 (76.2) 3.50 (88.9) — G 1.25 (31.8) 1.50 (38.1) 2.00 (50.8) 2.50 (63.5) H 3.25 (82.6) Sq. — — — C D B B B B B F D E E A E C E B B B B B F 1 E 1 E 1 Box 22, 24 Box 19, 20 1 Outdoor Commercial Enclosures 1 HUB Unit Enclosure Knockouts, Types ECB and ECC Knockouts Code HUB HUB HUB 1 Diameter 1 NEMA Type 1 Indoor (Flush and Surface Trims) A 0.50 (12.7) — — — — B 1.25 (31.8) 1.50 (38.1) 1.75 (44.5) 2.00 (50.8) 2.50 (63.5) 1 NEMA Type 3R Outdoor A 0.50 (12.7) — — — — B 1.25 (31.8) 1.50 (38.1) 1.75 (44.5) 2.00 (50.8) 2.50 (63.5) 1 1 1 E D C E E D B B B B B G 1 D F E E E D 1 C B B B B B E F A A Box 42 1 Box 43, 46, 47 1 Unit Enclosure Knockouts A B 1 HUB B B B B B B 1 1 B A NEMA Type 1—Indoor B B B B 1 A 1 NEMA Type 3R—Outdoor Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-69 1.2 1 1 1 1 1 1 1 1 1 1 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Technical Data and Specifications General A. The Contractor shall furnish and install deadfront loadcenters incorporating circuit breakers of the number, rating and type as specified herein and as shown on the contract drawings. Ratings A. Loadcenters shall be rated for 120/240 Vac and shall have short-circuit ratings as shown on the drawings or as herein scheduled, but not less than 10,000 amperes rms symmetrical. B. The loadcenter and all components shall be designed, manufactured and tested in accordance with the latest applicable standards of UL, NEMA and NEC including: B. Circuit breakers shall be a minimum of 125A frame. Circuit breakers 15 through 125A trip size shall take up the same pole spacing. 1. UL 67—Standards for Panelboards. 1 C. UL 50—Standards for Cabinets and Boxes. 1 D. UL 489—Standards for Molded Case Circuit Breakers. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 E. UL 869—Standards for Service Equipment. F. Federal Specification W-C 375B—Circuit Breakers. G. Federal Specification W-C P115b—Panel Power Distribution Type 1, Class 2. Qualifications A. The manufacturer of the loadcenter shall be the manufacturer of the circuit breaker within the loadcenter. B. For the equipment specified herein, the manufacturer shall be ISO 9000 certified. C. The manufacturer of this equipment shall have produced similar electrical equipment for a minimum period of seven (7) years. Manufacturers A. Eaton. C. Loadcenters shall be labeled with a UL shortcircuit rating. When series combination ratings are applied with integral or remote upstream devices, a label shall be provided. Series combination ratings shall cover all trip ratings of installed frames. It shall state the conditions of the UL series ratings including: 1. Size and type of upstream device. 2. Branch devices that can be used. 3. UL series short circuit rating. Construction A. All interiors, with the exception of the branch circuit breakers, shall be completely factory assembled with main breakers, main lugs, or no main device. B. Interiors shall be designed so that circuit breakers can be replaced without disturbing adjacent units and without removing the main bus connectors and shall be designed so that circuits may be changed without machining, drilling, or tapping. C. Physical means shall be provided to prevent the installation of more overcurrent devices than that number for which the enclosure was designed, rated and approved. Half-size breakers shall have a UL listed rejection tab over the line terminals. Loadcenter interiors must have notched stabs to accept these rejection tab class CTL breakers, if required and approved. Bus A. Busbars for the main and cross connectors shall be [tin-plated aluminum] [copper] in accordance with Underwriters Laboratories standards. Busing shall be braced throughout to conform to industry standard practice governing short-circuit stresses in loadcenters. Note: Note to spec writer— select one (copper available in limited ratings). B. Neutral busing shall have a suitable lug for each outgoing feeder requiring a neutral connection of same ampacity as branch. Wiring/Termination A. All wire connectors and terminals shall be of the anti-turn solderless type and shall be suitable for copper or aluminum wire of the sizes indicated. All connectors must meet the “Requirements for Wire Connectors and Soldering Lugs” as stated in UL 486B. B. All loadcenters where marked shall be suitable for use with 60°C or 75°C rated wire. 1 1 1 V1-T1-70 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com Circuit Breakers A. Circuit breakers shall be molded case type. Circuit breakers shall have four-rivet construction (GFI Type— 5 rivets). Multipole circuit breakers shall be of a stack pole design to provide electrical phase isolation. B. Each pole of the circuit breaker will provide inverse time delay overload and instantaneous shortcircuit protection by means of both thermal and magnetic sensors. C. The circuit breaker calibration shall not be affected by environmental changes in relative humidity. The thermal bimetal element shall be welded to the steel frame and calibration shall be set independent of the molded case by computer controlled equipment. D. All circuit breakers shall be operated by a toggle-type handle and multipole circuit breakers shall have an internal common trip mechanism. The circuit breakers shall incorporate trip mechanisms that are mechanically trip-free from the handle. The handle position shall provide visual trip indication. E. Contacts shall be of non-welding silver alloy. F. All circuit breakers shall have the trip rating inscribed on the handle on each circuit breaker pole. Also, unique colorcoded cases that indicate the UL listed 10 kA or 22 kA interrupting ratings. Breakers shall be able to be used as main or branch disconnect devices. Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers G. Branch circuit breakers may also be used in the 1/2-inch (12.7 mm) per pole ratings that include two-pole 1-inch (25.4 mm) wide modules and four-pole 2-inch (50.8 mm) wide modules. Two-pole circuit breakers must incorporate a common trip mechanism. The exclusive CTL rejection tab feature shall be provided to limit the number of branch devices for a loadcenter to 42, in compliance with NEC Article 384.15. H. Circuit breakers shall be completely enclosed in a molded case of thermoset material. No internal aluminum parts shall be used. All internal ferrous parts shall be plated to prevent corrosion. I. All terminals shall be listed for use with copper or aluminum conductors. Terminals shall be of the box lug or clamp type design. The terminals shall meet UL 486B requirements and shall be suitable for use with either 60°C or 75°C wire. J. The calibrated bimetal assembly shall be mechanically isolated from the load terminal using a flexible braided copper shunt wire, such that movement of the terminals due to twisting and overtorquing does not affect breaker calibration. K. Breakers shall be SWD rated and/or HACR rated as required. L. Arc Fault Interrupting circuit breakers, (AFI), shall be provided on all 15 and 20A single-phase 120/240 Vac circuits except those indicated as remote controlled breakers. AFI breakers shall be “Classified for mitigating the effects of arcing faults,” or conforming to UL Standard 1699 and as defined by Article 210.12 Section A of the 1999 NEC Code. Surge Protection Devices See Volume 1, Tab 2 for complete details on surge protection. Enclosures A. Loadcenter shall have NEMA Type 1 general purpose or NEMA Type 3R rainproof enclosures as indicated on the drawings and shall be surface or combination flush/surface mounted except where noted. B. Boxes shall be made from galvanized sheet steel having multiple knockouts. Rainproof boxes shall use galvanized steel or an approved coating system which meets or exceeds standards for outdoor NEMA Type 3R enclosures. Boxes shall be of sufficient size to provide at least a minimum code gutter space on all sides. 1.2 C. The deadfront shall have an easy adjustment feature for flush applications. 1 D. Boxes shall be factory assembled into a single rigid structure. 1 1 1 E. Unless otherwise noted on drawings, hinged doors covering all circuit breaker handles shall be included in all trims. Trim doors shall not uncover any live parts in making the circuit breaker handles accessible. If key locks are required, all locks shall be keyed alike. 1 1 1 1 1 1 F. Combination trims for flush and surface panels shall be flat and shall overlap the box by at least 5/8-inch (15.9 mm) all around. Trims shall be mounted by a screwdriver without the need for special tools. 1 1 1 1 Finish A. Trims shall be bonderized and finished with a light gray ANSI-61 enamel. The paint finish shall be of a type to which field applied paint will adhere. 1 1 1 Factory Testing A. The standard factory tests shall be performed on the equipment provided under this section. All tests shall be in accordance with the latest version of UL and NEMA. 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-71 1.2 1 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Contents—BR Specialty Products Type BR Retrofit Interior Description 1 Page Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BR Specialty Products Spa Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . Riser Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . Type BR Renovation Loadcenter . . . . . . . . . . . Type BR Mechanical Interlock Kits . . . . . . . . . . Type BR Retrofit Interior Kits BR Circuit Breakers. . . . . . . . . . . . . . . . . . . . . . . . 1 1 1 1 V1-T1-42 V1-T1-57 V1-T1-58 V1-T1-59 V1-T1-61 V1-T1-75 1 1 Type BR Retrofit Adjustable Interior Type BR Retrofit Interior Collar and Assembly with Trim 1 1 1 Type BR Retrofit Interior Kits 1 Product Description Application Description Eaton’s unique Retrofit Interior allows the customer to cost-effectively and safely upgrade an electrical service without removing the existing enclosure from the wall. The Retrofit Interior is designed and tested specifically for renovating an outdated electrical panel in an apartment, a condominium or a single family home. These outdated panels are being recognized by local inspectors and other authorities as a possible hazard. 1 1 1 1 1 1 1 1 1 1 1 Quick-ProSM All you need to know to save time and make more money. Specified on certain Eaton products, the Quick-Pro symbol allows for immediate recognition of products that are designed for straightforward installation. When you see Quick-Pro, you know you can install quickly—sometimes up to 50% less than the usual installation time—and move on to your next job. 1 1 1 1 1 Opportunities to Retrofit ● Single- or three-phase ● Main lug only or main breaker ● Up to 42 circuits ● Up to 225A interiors, 400A available upon request ● Available with CH breakers (3/4-inch) with copper bus or BR breakers (1-inch) with aluminum bus ● The minimum lifetime warranty for residential breakers shall be as follows: ● 10-year warranty on all BR branch breakers and loadcenters ● Refer to Eaton for complete warranty details Features and Benefits Upgrading Existing Electrical Infrastructure Is Simple ● Replaces vintage brands that have hard to find, expensive replacement breakers ● Safety upgrade to arc fault and ground fault breakers to meet current electrical codes ● Maximizes number of circuits available with compact design ● Eco-friendly in asbestosfilled environments ● Exclusive design Save Time and Money Throughout the Installation ● Uses existing panel box and wires ● Eliminates expensive and time-consuming drywall/ paint repair ● Saves 2–3 hours of installation time compared to a complete panel changeout ● Eliminates precise measurements with fieldadjustable kit 1 1 V1-T1-72 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com Detailed Product Guide All standard retrofit kits are suitable for a range of existing box sizes: ● ● ● Box width ranging from 14.50 to 22.00 inches (368.3 to 558.8 mm) Box depth ranging from 4.00 inches (101.6 mm) for BR Box height ranging from 21.00 to 45.00 inches (533.4 to 1143.0 mm) For box dimensions outside of these ranges, contact the Lincoln Flex Center at 800-330-6479. Be sure to provide the existing incoming line wire size. Standards and Certifications ● ● Meets 2008/2011/2014 NEC wire bending requirements UL 67 Listed (for UL listings for specific part numbers, see the table on the following page. 1.2 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers BR Specialty Product Selection 1 To select the retrofit kit: 1. From the existing box size determine which retrofit groups are suitable (may be more than one). 2. Use type of interior, number of phases, and type of main to find the selection chart. 3. Select part number from chart (if main breaker, replace XXX with specific amp rating). 4. Note that the overlap of the existing wall is the retro cover size minus the existing box size. If specific measurements are needed, communicate that you need a custom trim size. 5. Contact the Lincoln Flex Center at 800-330-6479 for pricing, lead-times, and order entry instructions. How to Order: 1. Measure the existing panel enclosure to determine appropriate kits for your project. Need assistance or can’t find retrofit to fit existing enclosure? 2. Match the existing dimensions with the table below to obtain the correct catalog number. 3. Order your retrofit kit from a local Eaton authorized distributor. Call Eaton’s Residential Flex Center at 1-800-330-6479 or email for all your retrofit needs. Go to www.eaton.com/eccn to locate an Eaton Certified Contractor. 1 1 1 1 Minimum Depth Maximum Depth Minimum Width Minimum Height Phase Main Bus Amperes 3 Spaces / Circuits UL 67 Listed CRTBR8ML**** 3.13 (79.5) 3.63 (92.2) 10.50 (266.7) 13.00 (330.2) Single MLO BR 100 16 Yes RUBR8L100_ CRUBR8ML**** 3.75 (95.3) 6.00 (152.4) 10.50 (266.7) 13.00 (330.2) Single MLO BR 100 16 Yes RTBR12L100P CRTBR12ML**** 3.13 (79.5) 3.63 (92.2) 10.50 (266.7) 14.50 (368.3) Single MLO BR 100 24 Yes RTBR10B100P CRTBR12ML**** 3.13 (79.5) 3.63 (92.2) 10.50 (266.7) 14.50 (368.3) Single MLO BR 100 20 Yes RUBR12L100_ CRUBR12ML**** 3.75 (95.3) 6.00 (152.4) 10.50 (266.7) 14.50 (368.3) Single MLO BR 100 24 Yes RUBR10B100_ CRUBR12ML**** 3.75 (95.3) 6.00 (152.4) 10.50 (266.7) 14.50 (368.3) Single MB BR 100 20 Yes RTBR12L125P CRTBR12ML**** 3.13 (79.5) 3.63 (92.2) 11.00 (279.4) 17.00 (431.8) Single MLO BR 125 24 Yes RTBR10B125P CRTBR12ML**** 3.13 (79.5) 3.63 (92.2) 11.00 (279.4) 17.00 (431.8) Single MB BR 125 20 Yes RUBR12L125_ CRUBR12ML**** 3.75 (95.3) 6.00 (152.4) 11.00 (279.4) 17.00 (431.8) Single MLO BR 125 24 Yes RUBR10B125_ CRUBR12ML**** 3.75 (95.3) 6.00 (152.4) 11.00 (279.4) 17.00 (431.8) Single MB BR 125 20 Yes RABR20B125_ CRABR20ML**** 3.75 (95.3) 6.00 (152.4) 13.00 (330.2) 21.00 (533.4) Single MCB BR 125 24 No RABR20L125_ CRABR20ML**** 3.75 (95.3) 6.00 (152.4) 13.00 (330.2) 21.00 (533.4) Single MLO BR 125 24 No RBBR20B200_ CRBBR20BW**** 3.75 (95.3) 6.00 (152.4) 13.00 (330.2) 29.00 (736.6) Single MLO BR 200 40 No RCBR40L200_ CRCBR40ML**** 3.75 (95.3) 6.00 (152.4) 13.00 (330.2) 34.00 (863.6) Single MLO BR 200 40 No RDBR40B200_ CRDBR40BW**** 3.75 (95.3) 6.00 (152.4) 13.00 (330.2) 37.00 (939.8) Single MLO BR 200 40 No BR Retrofit Interiors and Covers RTBR8L100P 1 1 Existing Enclosure Parameters—Inches (mm) Cover 2 1 1 Retrofit Interior Kit Specifications Five recommended groups: existing box height determines retro group size. Approximate Dimensions in Inches (mm). Catalog Number 1 1 Notes 1 Catalog numbers shown with "_" at the end need one of the following suffixes to denote depth: J = 3.75–4.25 K = 4.25–5.00 L = 5.00–6.00 Example: RTBR12L125J would signify an interior set with a depth range of 3.75 to 4.25 inches. 2 ****Denotes characters in the catalog number that relate to overall cover size. Example: CRTBR12ML2620 would signify a cover 26.00 inches H x 20.00 inches W. 3 Amperes for MB panels is maximum; catalog number will reflect actual amperage of breaker included. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 For UL applications, maximum cover sizes may apply. 1 1 1 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-73 1.2 1 1 1 1 Note: For complete assembly, interior and cover need to be ordered separately. Adjustable Interior ● ● 1 ● 1 Type BR Loadcenters and Circuit Breakers Complete Assembly 1 1 Loadcenters and Circuit Breakers ● Factory installed ground and neutral bars positioned to accept existing wires Field adjustable depth matches existing panel box Adjustable height enables optional placement of the interior Field bondable for service entrance options Standard Trim and Collar ● ● ● Standard trim matches new interior New circuit directory for updated labeling Oversized collar eliminates expensive wall/paint repair 1 1 1 Adjustable Interior Collar and Assembly with Trim 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V1-T1-74 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers 1.2 Contents BR Circuit Breakers Description Page Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . BR Specialty Products Spa Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . Riser Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type BR Renovation Loadcenter . . . . . . . . . . . Type BR Mechanical Interlock Kits . . . . . . . . . . Type BR Retrofit Interior Kits . . . . . . . . . . . . . . BR Circuit Breakers Product Selection . . . . . . . . . . . . . . . . . . . . . . . Circuit Breaker Accessories . . . . . . . . . . . . . . . Wiring Diagrams. . . . . . . . . . . . . . . . . . . . . . . . V1-T1-42 V1-T1-57 V1-T1-58 V1-T1-59 V1-T1-61 V1-T1-72 V1-T1-76 V1-T1-84 V1-T1-86 1 1 1 1 1 1 1 1 1 1 BR Circuit Breakers 1 Product Description 1 Plug-On Branch Feeder Type Arc Fault Circuit Breakers, Type BR—10 kAIC, 120 Vac and 120/240 Vac A branch feeder type arc fault circuit interrupter is a device intended to mitigate high current arcing faults in the complete circuit, including connected cords. High current arcing faults can occur from line to neutral or line to ground. These arcing faults are in parallel with the load and produce the most energy of all arcing faults. The branch feeder type AFCI is required in the 1999 and 2002 National Electrical Code. The Combination Type AFCI is required in the 2005, 2008, and 2011 National Electrical Code. Plug-On Combination Type Arc Fault Circuit Breakers, Type BR—10 kAIC, 120 Vac and 120/240 Vac A combination type arc fault circuit interrupter is a device that includes all of the protection offered by the branch feeder AFCI (mitigation of high current arcing faults in the complete circuit, including connected cords). In addition it provides direct detection of persistent low current arcing faults down to 5 amps with associated mitigation of fire hazards in the cords connected to the outlets. High current arcing faults can occur from line to neutral or line to ground. These arcing faults are in parallel with the load and produce the most energy of all arcing faults. The current level of low current arcing faults is limited by the load. Plug-On Ground Fault Circuit Breakers, Type GFCB and GFEP—10/22 kAIC, 120 Vac and 120/240 Vac Ground Fault Application Notes Single-pole GFCBs are designed for use in twowire, 120 Vac circuits. See Page V1-T1-86 for a typical wiring configuration. Two-pole GFCBs are designed for use in threewire, 120/240 Vac circuits, 120 Vac multiwire circuits employing common, neutral and two-wire, 240 Vac circuits obtained from a 120/240 Vac source. Page V1-T1-86 shows typical wiring configurations for a 120/240 Vac multiwire circuits, and a 240 Vac, twowire circuit. Note the “panel neutral” conductor connects to the neutral bar, even though the neutral is not included in the load circuit. This connection is necessary to supply a 120 Vac power source to the ground fault sensing circuit. The figures are shown with a 120/240 Vac, single-phase, three-wire power source, but are also applicable to a 120/208 Vac, three-phase, four-wire power supply. For all figures, the electrical operation of the GFCB is not affected by the equipment ground. 1 Non-CTL Plug-On Replacement —Circuit Breakers, Type BRD— 10 kAIC, 120/240 Vac 1 Non-CTL 10 kAIC for Replacement Purposes Only For replacement in enclosures manufactured prior to 1968 with unnotched stabs. Circuit breakers do not have rejection tab. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-75 1.2 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers 1 Product Selection 1 Plug-On Circuit Breakers, Types BR—10/22/42 kAIC, 120 Vac, 120/240 Vac and 240 Vac 1 BR120 Type BR Breakers, 1-Inch (25.4 mm) per Pole 120/240, 10, 22 and 42 kAIC 1 1 Single-Pole 120/240 Vac Requires One 1-Inch (25.4 mm) Space Two-Pole 120/240 Vac Common Trip Requires Two 1-Inch (25.4 mm) Spaces 10 per Shelf Carton 5 per Shelf Carton 10 kAIC 22 kAIC 10 kAIC 22 kAIC 42 kAIC Catalog Number Catalog Number Catalog Number Catalog Number Ampere Rating Wire Size Range Cu/Al 60°C or 75°C Catalog Number 10 #14–4 BR110 — BR210 — — 15 #14–4 BR115 12 BRH115 BR215 3 BRH215 — 20 #14–4 BR120 12 BRH120 BR220 3 BRH220 — 25 #14–4 BR125 BRH125 BR225 3 BRH225 — 1 30 #14–4 BR130 BRH130 BR230 3 BRH230 — 35 #14–4 BR135 BRH135 BR235 3 BRH235 — 1 40 #14–4 BR140 BRH140 BR240 3 BRH240 3 — 45 #14–4 — BRH145 BR245 3 BRH245 — 50 #14–4 BR150 BRH150 BR250 3 BRH250 3 — 1 55 #14–3 BR150 BRH155 BR255 BRH255 — 60 #8–1/0 BR160 BRH160 BR260 BRH260 BRHH260 1 70 #8–1/0 BR170 BRH170 BR270 BRH270 BRHH270 80 #8–1/0 — — BR280 BRH280 BRHH280 90 #8–1/0 — — BR290 BRH290 BRHH290 100 #8–1/0 — — BR2100 BRH2100 BRHH2100 110 #8–1/0 — — BR2110 BRH2110 BRHH2110 125 #4–2/0 — — BR2125 BRH2125 BRHH2125 150 #4–2/0 — — BR2150 4 — — 1 1 BR215 1 BR320 1 1 BRH2100 1 1 1 Notes 1 One pole, 1-inch (25.4 mm) per pole circuit breakers are available with high magnetic setting for switching large tungsten lamp loads. Add suffix H to catalog number. 2 Switching duty rated. 3 On the black handle breaker, add suffix “B” to the catalog number to obtain a tapped molded opening for proper use with hold-down kits. 4 For use as a branch circuit breaker in 400 and 600 ampere panels only. 1 1 1 All Type BR single-, two- and three-pole circuit breakers carry listing for HACR application. For circuit breakers with a shunt trip, add ST suffix. 1 1 1 1 1 1 1 1 1 1 V1-T1-76 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers BR Breakers 1.2 Type BR Breakers, 1-Inch (25.4 mm) per Pole 240 Vac, 10, 22 and 42 kAIC 1 Three-Pole 240 Vac Common Trip Requires Three 1-Inch (25.4 mm) Spaces 1 5 per Shelf Carton Ampere Rating Wire Size Range Cu/Al 60°C or 75°C 10 kAIC 22 kAIC Catalog Number Catalog Number 10 #14–4 BR310 — 1 BRH315 BRH320 15 #14–4 BR315 20 #14–4 BR320 1 25 #14–4 BR325 BRH325 30 #14–4 BR330 BRH330 35 #14–4 BR335 BRH335 40 #14–4 BR340 BRH340 45 #14–4 BR345 BRH345 50 #14–4 BR350 BRH350 55 #14–3 BR355 BRH355 60 #4–1/0 BR360 BRH360 70 #4–1/0 BR370 BRH370 80 #4–1/0 BR380 BRH380 90 #4–1/0 BR390 BRH390 100 #4–1/0 BR3100 BRH3100 1 1 1 1 1 1 1 1 1 1 1 Plug-On Branch Feeder Type Arc Fault Circuit Breakers, Type BR—10 kAIC, 120 Vac and 120/240 Vac 1 Type BR, 1-Inch (25.4 mm) Wide FIRE-GUARD AFCI Circuit Breakers 1 Type BR AFCI Circuit Breaker Ampere Rating Configuration Catalog Number Single-pole 10 kAIC 15 AFCI BR115AF 2 20 AFCI BR120AF 2 Single-pole 22 kAIC 15 AFCI BRH115AF Poles Two-pole 10 kAIC 34 20 AFCI BRH120AF 15 AFCI Common Trip BRL215AF 20 AFCI Common Trip BRL220AF 1 1 1 1 Notes 1 One pole, 1-inch (25.4 mm) per pole circuit breakers are available with high magnetic setting for switching large tungsten lamp loads. Add suffix H to catalog number. 2 Clamshell packaging available with CS modification code on the end of catalog number. 3 Common trip refers to two-pole 240V load application sourced by 120/240 Vac (see Page V1-T1-86). 4 Independent trip refers to two-pole multi-wire, home run or shared neutral circuits (see Pages V1-T1-86 and V1-T1-87). All Type BR single-, two- and three-pole circuit breakers carry listing for HACR application. For circuit breakers with a shunt trip, add ST suffix. 1 1 1 1 1 1 1 1 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-77 1.2 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers 1 Plug-On Combination Type Arc Fault Circuit Breakers, Type BR—10 kAIC, 120 Vac and 120/240 Vac 1 BRCAF115 Type BR, 1-Inch (25.4 mm) wide FIRE-GUARD Combination Type AFCI Circuit Breakers 1 Poles 1 Single-pole 10 kAIC Ampere Rating AFCI BRCAF115 1 BRACAF115 AFCI BRCAF120 1 Diagnostic AFCI BRACAF120 15 AFCI BRHCAF115 1 20 AFCI BRHCAF120 1 15 AFCI BRL215CAF 20 AFCI BRL220CAF 20 1 Single-pole 22 kAIC 1 Two-pole 10 kAIC 1 Catalog Number Diagnostic AFCI 15 1 Configuration 1 Plug-On Ground Fault Circuit Breakers, Type GFCB and GFEP—10/22 kAIC, 120 Vac and 120/240 Vac 1 Type GFCB Single-Pole 1 Type GFCB Ground Fault Circuit Breakers—5 Milliampere— 1-Inch (25.4 mm) per Pole 120 Vac or 120/240 Vac, 10 kAIC 1 Single-Pole 120 Vac Requires One 1-Inch (25.4 mm) Space 1 Two-Pole 120/240 Vac Common Trip Requires Two 1-Inch (25.4 mm) Spaces Ampere Rating Wire Size Range Cu/Al 60°C or 75°C 1 per Shelf Carton 1 per Shelf Carton Catalog Number 2 Catalog Number 1 15 #14–4 GFCB115 GFCB215 20 #14–4 GFCB120 GFCB220 1 25 #14–4 GFCB125 GFCB225 30 #14–4 GFCB130 GFCB230 1 40 #14–4 GFCB140 GFCB240 1 50 #14–4 — GFCB250 3 60 #14–6 — GFCB260 1 Type GFCB Two-Pole 1 Notes 1 Clamshell packaging available with CS modification code on the end of catalog number. 2 Available with bell alarm or auxiliary switch. See circuit breaker accessories on Page V1-T1-84. 3 For use with copper wire only. 1 1 1 1 1 1 1 1 1 1 1 V1-T1-78 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers 1.2 Type GFCBH Ground Fault Breakers—5 Milliampere— 1-Inch (25.4 mm) per Pole 120 Vac or 120/240 Vac, 22 kAIC 1 1 Single-Pole 120 Vac Requires One 1-Inch (25.4 mm) Space Two-Pole 120/240 Vac Common Trip Requires Two 1-Inch (25.4 mm) Spaces Ampere Rating Wire Size Range Cu/Al 60°C or 75°C 1 per Shelf Carton 1 per Shelf Carton Catalog Number Catalog Number 15 #14–4 GFCBH115 GFCBH215 20 #14–4 GFCBH120 GFCBH220 25 #14–4 GFCBH125 GFCBH225 30 #14–4 GFCBH130 GFCBH230 1 1 1 1 1 1 Type GFEP Ground Fault Equipment Protectors—30 Milliampere— 1-Inch (25.4 mm) per Pole 120 Vac or 120/240 Vac, 10 kAIC 1 1 Single-Pole 120 Vac Requires One 1-Inch (25.4 mm) Space Two-Pole 120/240 Vac Common Trip Requires Two 1-Inch (25.4 mm) Space Ampere Rating Wire Size Range Cu/Al 60°C or 75°C 1 per Shelf Carton 1 per Shelf Carton Catalog Number Catalog Number 15 #14–4 GFEP115 GFEP215 20 #14–4 GFEP120 GFEP220 25 #14–4 GFEP125 GFEP225 30 #14–4 GFEP130 GFEP230 40 #14–4 — GFEP240 50 #14–4 — GFEP250 1 1 1 1 1 1 1 1 Note 1 For use with copper wire only. 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-79 1.2 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers 1 CTL Plug-On Circuit Breakers, Type BD Duplex, BQ and BQC Quadplex—10 kAIC, 120/240 Vac 1 BD2020 1 Type BQ Quadplex Independent Trip (UL Type BRD) Single-Pole 1 Requires One 1-Inch (25.4 mm) Space 10 per Shelf Carton 1 120 Vac BQ2302115 Type BQ Quadplex Independent Trip (UL Type BRD) 120 Vac 120/240 Vac 120 Vac 120/240 Vac 120/240 Vac 1 1 Class CTL, 1-Inch (25.4 mm) per Pole 10 kAIC—All Circuit Breakers Have Rejection Tab Feature Type BD Duplex (UL Type BRD) 120/240 Vac 120/240 Vac Two-Pole 2 and Single-Pole 1 Requires Two 1-Inch (25.4 mm) Spaces 5 per Shelf Carton 120 Vac 120/240 Vac Two-Pole Requires Two 1-Inch (25.4 mm) Spaces 5 per Shelf Carton 120 Vac 120/240 Vac 1 Ampere Rating Catalog Number Wire Size Range Cu/Al 65°C or 75°C 1 10–10 BD1010 #14–4 15 20 15 BQ2202115 15 15 BQ215215 15–15 BD1515 #14–4 20 20 20 BQ2202120 15 20 BQ215220 15–20 BD1520 #14–4 15 30 15 BQ2302115 15 30 BQ215230 15–30 BD1530 #14–4 20 30 20 BQ2302120 15 40 BQ215240 20–15 BD2015 #14–4 15 40 15 BQ2402115 15 50 BQ215250 1 20–20 BD2020 #14–4 20 40 20 BQ2402120 20 20 BQ220220 20–30 BD2030 #14–4 15 50 15 BQ2502115 20 30 BQ220230 1 25–25 BD2525 #14–4 20 50 20 BQ2502120 20 40 BQ220240 30–15 BD3015 #14–4 — — — — 20 50 BQ220250 1 30–20 BD3020 #14–4 — — — — 25 25 BQ225225 1 30–30 BD3030 #14–4 — — — — 30 30 BQ230230 30–40 BD3040 #14–4 — — — — 30 40 BQ230240 1 30–50 BD3050 #14–4 — — — — 30 50 BQ230250 50–30 BD5030 #14–4 — — — — 40 40 BQ240240 1 50–50 BD5050 #14–4 — — — — 40 50 BQ240250 — — — — — — — 50 50 BQ250250 1 1 BQ230230 1 Ampere Rating Ampere Rating Outer Left Center Two-Pole Outer Right Catalog Single-Pole Independent Trip Single-Pole Number Outer Two-Pole Center Two-Pole Catalog Independent Trip Independent Trip Number Notes 1 All 15 and 20A single poles are switch-duty rated. 2 All Type BD duplex and BQ quadplex circuit breakers carry listing for HACR applications. 1 1 1 1 1 1 1 1 1 1 1 1 1 V1-T1-80 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers 1.2 Non-CTL Plug-On Replacement—Circuit Breakers, Type BRD—10 kAIC, 120/240 Vac BR2020 1 Class Non-CTL, 1-Inch (25.4 mm) per Pole 10 kAIC—Breakers Do Not Have Rejection Tab Feature Type BR Duplex 120/240 Vac 120/240 Vac 120/240 Vac 120 Vac Ampere Rating Catalog Number Wire Size Range Cu/Al 65°C or 75°C 15–15 BR1515 15–20 20–15 1 120/240 Vac 120/240 Vac Single-Pole Requires One 1-Inch (25.4 mm) Space 10 per Shelf Carton 1 Type BRD Quadplex Common Trip Center and Outer Poles Type Brand BRD Quadplex Independent Trip 120/240 Vac Two-Pole Requires Two 1-Inch (25.4 mm) Spaces 5 per Shelf Carton Two-Pole Requires Two 1-Inch (25.4 mm) Spaces 5 per Shelf Carton 120/240 Vac 120/240 Vac 120/240 Vac Ampere Rating 1 1 Ampere Rating Outer Two-Pole Independent Trip Center Two-Pole Independent Trip Catalog Number Outer Two-Pole Common Trip Center Two-Pole Common Trip Catalog Number #14–4 15 15 BR415 15 15 BRDC215215 BR1520 #14–4 20 20 BR420 30 30 BRDC230230 BR2015 #14–4 30 30 BR430 30 40 BRDC230240 20–20 BR2020 #14–4 20 30 BRD220230 30 50 BRDC230250 30–30 BR3030 #14–4 30 40 BRD230240 — — — 30–50 BR3050 #14–4 30 50 BRD230250 — — — Unnotched Bus Stab 1 1 1 1 Type BR or Type BD Duplex, (CTL), Type BQ and BQC Quadplex CTL Circuit Limiting Feature 1 Type BD Duplex 1 Rejection Tab Type BR 1 1 CTL and Non-CTL Breakers Notched Bus Stab 1 Notched Stab Non-CTL Non-Circuit Limiting 1 Type BR 1 1 1 Note Type BD Duplex, BQ and BQC Quadplex circuit breakers can be installed in Circuit Limiting (CTL) listed BR loadcenters. Type BR twin breakers can be installed in Non-CTL BR loadcenters. 1 1 1 1 1 1 1 1 1 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-81 1.2 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers 1 Common Trip Quadplex Breakers 1 BQC2302115 1 Type BQC Quadplex Common Trip Center and Outer Poles (UL Type BRD) 120 Vac 120/240 Vac 120 Vac 1 120/240 Vac 120/240 Vac Two-Pole 1 and Single-Pole 2 Requires Two 1-Inch (25.4 mm) Spaces 5 per Shelf Carton 1 1 Class CTL, 1-Inch (25.4 mm) per Pole 10 kAIC—All Circuit Breakers Have Rejection Tab Feature Type BQC Quadplex Common Trip Center Poles (UL Type BRD) 120 Vac 120/240 Vac Two-Pole 1 Requires Two 1-Inch (25.4 mm) Spaces 5 per Shelf Carton 120 Vac 120/240 Vac Ampere Rating Ampere Rating Outer Two-Pole Common Trip Center Two-Pole Common Trip Catalog Number Outer Left Single-Pole Center Two-Pole Common Trip Outer Right Single-Pole Catalog Number Wire Size Range Cu/Al 65°C or 75°C 15 20 15 BQC2202115 #14–4 15 15 BQC215215 1 15 25 15 BQC2252115 #14–4 15 20 BQC215220 1 15 30 15 BQC2302115 #14–4 15 30 BQC215230 15 40 15 BQC2402115 #14–4 20 15 BQC220215 1 15 50 15 BQC2502115 #14–4 20 20 BQC220220 — — — — #14–4 20 30 BQC220230 1 — — — — #14–4 20 40 BQC220240 1 — — — — #14–4 20 50 BQC220250 20 15 20 BQC2152120 #14–4 25 25 BQC225225 1 20 20 20 BQC2202120 #14–4 25 30 BQC225230 20 25 20 BQC2252120 #14–4 30 15 BQC230215 1 20 30 20 BQC2302120 #14–4 30 30 BQC230230 20 40 20 BQC2402120 #14–4 30 40 BQC230240 1 20 50 20 BQC2502120 #14–4 30 50 BQC230250 1 30 50 20 BQC2502030 #14–4 40 30 BQC240230 — — — — #14–4 40 40 BQC240240 1 — — — — #14–4 40 50 BQC240250 — — — — #14–4 50 20 BQC250220 1 — — — — #14–4 50 50 BQC250250 BQC2302115 1 Notes 1 All Type BQC quadplex circuit breakers carry listing for HACR applications. 2 All 15 and 20 ampere single poles are switch-duty rated. 1 1 1 1 1 1 1 1 1 1 1 1 V1-T1-82 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com 1.2 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Plug-On Circuit Breakers, Types BJ and BJH—10/22 kAIC, 120/240 Vac and 240 Vac For Use in Single-Phase and Three-Phase Loadcenters—150 Amperes and Above Type BJ 1 1 Types BJ and BJH Breakers, 1-Inch (25.4 mm) per Pole, 120/240 or 240 Vac, 10, 22 kAIC 1 1 Three-Pole 240 Vac Common Trip Requires Six 1-Inch (25.4 mm) Spaces 2 5 per Shelf Carton Two-Pole 120/240 Vac Common Trip Requires Four 1-Inch (25.4 mm) Spaces 1 10 per Shelf Carton Ampere Rating 10 kAIC 22 kAIC Catalog Number 125 150 1 10 kAIC 22 kAIC Catalog Number Wire Size Range Cu/Al 60°C or 75°C Catalog Number Catalog Number BJ2125 BJH2125 #2–300 kcmil BJ3125 BJH3125 BJ2150 BJH2150 #2–300 kcmil BJ3150 BJH3150 175 BJ2175 BJH2175 #2–300 kcmil BJ3175 BJH3175 200 BJ2200 BJH2200 #2–300 kcmil BJ3200 BJH3200 225 BJ2225 BJH2225 #2–300 kcmil BJ3225 BJH3225 1 1 1 1 Plug-On Special Application Circuit Breakers—10 kAIC, 120 Vac, 120/240 Vac and 240 Vac BRWH215 Water Heater Breaker 1 Special Application Circuit Breakers, 1-Inch (25.4 mm) per Pole Water Heater Breakers Switching Neutral Breakers LINE 240V Breakers Non-Automatic Molded Case Switches NEUTRAL BRSN220 Switching Neutral Breaker 1 1 OUT IN LOAD 1 Two-Pole 120/240 Vac Common Trip Requires Two 1-Inch (25.4 mm) Spaces Two-Pole 120 Vac Common Trip Requires Two 1-Inch (25.4 mm) Spaces With Isolated Line Terminals for Separately Metered Water Heaters With Switching Neutral Pole for Gasoline Pump Applications Ampere Rating Catalog Number Ampere Rating Catalog Number Wire Size Range Cu/Al 60°C or 75°C 15 BRWH215 15 BRSN215 20 BRWH220 20 30 BRWH230 25 — — — — — — 5 per Shelf Carton 5 per Shelf Carton 10 kAIC 10 kAIC 1 Two-Pole 240 Vac Common Trip Requires Two 1-Inch (25.4 mm) Spaces Two-Pole 240 Vac Requires Two 1-Inch (25.4 mm) Spaces Where Voltage to Ground is 240 Vac For Use as Disconnect Contains No Magnetic or Thermal Trip Properties 5 per Shelf Carton 5 per Shelf Carton 10 kAIC 5 kAIC Ampere Rating Catalog Number Ampere Rating Catalog Number #14–4 10 BR210H — — BRSN220 #14–4 15 BR215H — — BRSN225 #14–4 20 BR220H — — 30 BRSN230 #14–4 25 BR225H — — — — #14–4 30 BR230H — — — — — #14–4 35 BR235H — — — — — #14–4 40 BR240H — — — — — — #14–4 45 BR245H — — — — — — #14–4 50 BR250H 50 BR250NA — — — — #14–4 55 BR255H — — — — — — #4–1/0 60 BR260H 60 BR260NA — — — — #4–1/0 70 BR270H — — — — — — #4–1/0 80 BR280H — — — — — — #4–1/0 90 BR290H — — — — — — #4–1/0 100 BR2100H 100 BR2100NA 1 1 1 1 1 1 1 1 1 1 1 1 1 Notes 1 Breaker uses two 1-inch (25.4 mm) pole spaces on left side and two 1-inch (25.4 mm) pole spaces on right side of loadcenter. 2 Breaker uses three 1-inch (25.4 mm) pole spaces on left side and three 1-inch (25.4 mm) pole spaces on right side of loadcenter. 1 If BJ or BJH breakers are used as a main or a back feed device, a hold-down kit is required. See Page V1-T1-84. 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-83 1.2 1 1 THS1 Ordering Quantity 1 Catalog Number Handle tie bar for physically joining the handles of two adjacent single-pole Type BR circuit breakers (metal cylinder pin type) 10 BHT Handle tie bar for joining two independent outside poles of Types BQ and BQC Quadplex and outside poles of two Type BD duplex circuit breakers 10 THOW Handle Ties 2 BHLW2 1 Handle tie bar for joining two adjacent outside poles of Types BQ and BQC Quadplex and outside poles of two Type BD duplex circuit breakers 10 BRQLW 1 1 Field Installation Kits and Parts Description 1 1 Type BR Loadcenters and Circuit Breakers Circuit Breaker Accessories 1 1 Loadcenters and Circuit Breakers MCBPL (Installed) Handle Lockoffs THS1 34 Padlockable device for locking the handle of single-, two- or three-pole Type BR Circuit Breakers and single-pole of a Type BD Duplex or one independent outside pole of a Type BQ or BQC Quadplex circuit breakers (escutcheon mounted) 5 10 BRLW Padlockable device for locking the handle of a single-pole Type BR circuit breaker (handle mounted) 6 10 BRLW1 10 BRLW2 10 BRDL1 Padlockable device for locking the handle of a two- and three-pole Type BR circuit breaker (handle mounted) 6 1 Padlockable device for locking the handle of a single-pole Type BD Duplex, BQ or BQC Quadplex breaker (handle 1 Padlockable device for locking the handle of the two center poles and the two outer poles of a two-pole Types BQ and BQC quadplex circuit breakers (escutcheon mounted) 5 10 BRQLW 1 Padlockable device for locking the handle of main circuit breaker Types CC and CHH into the ON or OFF position (screw mounted) 7 1 CCPL Padlockable device for locking the handle of main breaker Types BW and CSR into the ON or OFF position (escutcheon Mounted) 5 1 MCBPL Device used to secure handle in ON or OFF position for single-, two- or three-pole Type BR circuit breakers and single-pole of Type BD duplex and one independent outside pole of Type BQ or BQC Quadplex circuit breakers (escutcheon mounted) 5 10 BHLW Device used to secure handle in ON or OFF position for single-pole Type BR circuit breakers (handle mounted) 6 10 BHLW1 Device used to secure handle in ON or OFF position for two- and three-pole Type BR circuit breakers (handle mounted) 6 10 BHLW2 1 Device used to secure handle in ON or OFF position for single-pole Type GFCB ground fault circuit breakers (handle mounted) 6 10 BHGW 1 Device used to secure handle in ON or OFF position for one independent outside pole of Types BQ and BQC Quadplex or single-pole Type BD duplex circuit breakers (handle mounted) 6 10 HLW1 Hold-down retainer kit for three-pole Type BR circuit breakers in S3100 and 3100R loadcenters only 1 BRHDB Hold-down screw kit for two- and three-pole Type BR circuit breakers in single-phase MLO loadcenters through 100–125A 1 BREQS125 Hold-down screw kit for two- and three-pole Type BR circuit breakers in MLO loadcenters 150–225A 1 BRHDK125 Hold-down screw kit for two-pole Types BJ and BJH circuit breakers in MLO loadcenters 125–225A 1 BJHDS Hold-down screw kit for three-pole Types BJ and BJH circuit breakers in MLO loadcenters 125–225A 1 BJHDS3P Types CC and CHH main breaker lug kit (2) 300 kcmil 1 CCL300 Types BW/CSR main breaker lug kit (2) 300 kcmil 1 MCBL300 1 BHLW 1 1 1 BRLW2 BREQS125 1 1 1 mounted) 6 Hold-Down Kits 8 BRHDK125 1 Main Breaker Lug Kits 1 1 Notes 1 Must be purchased in multiples of ordering quantities indicated. 2 Handle ties: typically used to join two similar independent single-pole breakers to form a two-pole noncommon trip breaker. 3 Handle lockoffs: devices that use a padlock to lock the circuit breaker’s handle in the ON or OFF position. 4 See table on Page V1-T1-85 for handle position changeability chart. 5 Escutcheon mounted: device mounted semipermanently to the face of the circuit breaker and secured by the loadcenter deadfront. 6 Handle mounted: device mounted directly to the handle by the use of a set screw. 7 Screw mounted: device permanently mounted to the face of the circuit breaker by the use of a non-removable screw. 8 Hold-down kits: devices used to secure the circuit breaker to the loadcenter for back-feed main application. See NEC Article 384.16(g). 1 1 1 1 1 1 V1-T1-84 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com 1.2 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers BRML Field Installation Kits and Parts, continued Description Ordering Quantity 1 Catalog Number 10 BRML 10 BRPLOFF 10 BRPLOFF2P 10 BRPLOFF3P 10 BJL2P 10 BJL3P 10 GHQRLOFF2P 10 GHQRLOFF 10 QCD123PLOFF Mechanical Interlocks Types BR for two-, three- and four-pole breakers 1 1 1 1 1 1 1 1 1 Shunt Trips, Auxiliary and Alarm Contacts 1 Catalog Number 2 Suffix Adder Description 1 Shunt Trip for Types BW/CSR 1 12 Volts SR12 24 Volts SR24 120 Volts SR01 1 ST 1 Shunt Trip for Types BR 120 Volts Auxiliary Contact for Types BW/CSR 1NO and 1NC AL1 2NO and 2NC AL2 1 1 Alarm Contacts for Types BW/CSR CR1 1 Alarm contact for GFCB (single-pole) W1 1 1NO and 1NC W2 Types BW/CSR Alarm Contacts for Type GFCB (Single-Pole) 1 1 Handle Position Changeability Chart 1 To Change Handle Position from ON to OFF, or OFF to ON You Must... Handle Lockoff and Lockdog Types Remove Padlock Remove Device Remove Loadcenter Deadfront Lockoff escutcheon mounted Remove — — Lockoff handle mounted Remove Remove — Lockoff screw mounted Remove — — Lockdog escutcheon mounted N/A Remove Remove Lockdog handle mounted N/A Remove — 1 1 1 1 1 Notes 1 Must be purchased in multiples of ordering quantities indicated. 2 Add suffix indicated to end of breaker catalog number. 1 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-85 1.2 1 1 1 Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers Wiring Diagrams Single-Pole 120V Load Application Sourced by 120/240 Vac Two-Pole Shared Neutral with Duplex Receptacle Application 120/240 Vac Source N A B 120/240 Vac Source N A B Line A 1 1 Line B Line B 1 Two-Pole Single-Pole Neutral 120V Duplex Receptacle Neutral 1 Neutral Neutral Equipment Ground 120V Duplex Receptacle (With Line Side Jumper Removed) Equipment Ground 1 1 1 1 Two-Pole Shared Neutral with Multi-Duplex Receptacle Application 120/240 Vac Source N A B 120/240 Vac Source N A B 1 1 1 1 Neutral Neutral Neutral Two 120V Duplex Receptacles Neutral 120V Duplex Receptacle Equipment Ground Equipment Ground Line A Two-Pole 240V Load Application Sourced by 120/240 Vac Single-Pole 120V Duplex Receptacle Application 120/240 Vac Source N A B 120/240 Vac Source N A B Line B 1 1 1 Single-Pole Two-Pole 1 1 Line B Line B 1 1 Single-Pole 120V Load Application Sourced by 120/240 Vac Line B Two-Pole Single-Pole Line A Neutral 1 240V Duplex Receptacle Neutral Neutral Equipment Ground 1 1 1 1 1 1 1 V1-T1-86 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com 120V Duplex Receptacle Loadcenters and Circuit Breakers Type BR Loadcenters and Circuit Breakers 1.2 Two-Pole 120V Multi-Duplex Receptacle Application 1 120/240 Vac Source N A B 1 1 Line B 1 Two-Pole Neutral Neutral Two 120V Duplex Receptacles 1 1 1 Line A 1 Two-Pole 120V Duplex Receptacle Application 1 120/240 Vac Source N A B 1 Line B 1 Line A 1 Two-Pole Neutral Neutral 120V Duplex Receptacle (With Line Side Jumper Removed) 1 1 1 Two-Pole 240V Duplex Receptacle Application 1 120/240 Vac Source N A B 1 1 Line B 1 Two-Pole Line A Neutral 1 240V Duplex Receptacle 1 1 1 1 1 1 1 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-87 1.3 1 Loadcenters and Circuit Breakers Loadcenter Interiors/OEM Loadcenters Contents OEM Loadcenters Description 1 Page Standards and Certifications . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . 1 V1-T1-89 V1-T1-89 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Product Description As a leader in the electrical distribution equipment business, Eaton has a unique product offering for equipment manufacturers, panel builders and virtually any OEM that has a need for power distribution within their equipment. The OEM interior offering consists of a wide variety of power distribution options utilizing components from Eaton’s CH and BR loadcenter product lines. With high-volume, standardized products, OEMs can expect to receive high-quality products covering configurations meeting virtually any power distribution need. Coupled with Eaton’s expertise in circuit breaker design and manufacturing, OEM interiors provide solid power distribution and circuit protection in a compact, easy-to-install package. Interiors are offered from 2 to 42 circuits and from 70 to 225A. 1 1 1 1 Quality Built in ISO 9002 certified manufacturing facilities, customers can be assured of the process quality in place for the manufacture of these products. Utilizing the latest in computer-controlled plating, painting, molding, stamping and welding processes, Eaton’s customers have come to expect consistent high-quality from shipment to shipment. Two Products Offer Design Flexibility As a manufacturer of two lines of loadcenters, Eaton is in a unique position to offer the broadest range of interiors in the market. Each line has its own unique characteristics that appeal to various segments of the market. OEM interiors are UL recognized components and are listed in either of the following UL files: E8741 or E52977. The CH interiors feature 100% copper bus and use the CH 3/4-inch (19.1 mm) wide circuit breaker, which minimizes panel space. Recognized by contractors for its sturdy design, the CH interior will appeal to those customers seeking an industrial quality bolted busbar and the space saving of 3/4-inch (19.1 mm) per bus stab. With a typical 12 circuit CH interior, this space savings amounts to an inch and a half savings over its 1-inch (25.4 mm) counterparts. The stab rating of the CH interiors is 140A maximum meaning that the handle rating of breakers mounted across from one another may not exceed 140A. The BR interiors are manufactured of formed, plated aluminum or copper, and use Eaton’s Type BR 1-inch (25.4 mm) wide circuit breaker. This design affords customers the most circuit flexibility as many of these interiors allow the installation of standard single- and two-pole breakers as well as duplex (two poles in a 1-inch (25.4 mm) space) or quadplex (four poles in a 2-inch (50.8 mm) space) breakers. 1 V1-T1-88 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com The stab rating of the BR interiors is 200A maximum, meaning that the handle rating of the breakers that are mounted across from one another may not exceed 200A. The interiors are designed for either horizontal (singlerow breaker mounting), or vertical (double-row breaker mounting). To comply with National Electrical Code (NEC) requirements, if mounted horizontally, when the breaker is ON, the handle should be in the UP position. When mounted vertically, the handle toggles from left to right, so this is not a concern. Loadcenters and Circuit Breakers Loadcenter Interiors/OEM Loadcenters 1.3 Standards and Certifications Class CTL Federal Specifications National Electrical Code Paragraph 384-15 requires branch circuit panelboards to be provided with physical means to prevent the installation of more overcurrent devices than that number of which the enclosure was designed, rated and approved. Class CTL Duplex, Quadplex and twin breakers (identified by a catalog number prefix BD, BQ, BQC and CHT) are equipped with a UL listed rejection tab over the line terminal. All OEM interiors have appropriately notched stabs to accept these rejection tab Class CTL breakers. All loadcenter enclosures meet Federal Specifications W-P-115b, Type 1, Class 2 requirements. Duplex, Quadplex and twin breakers manufactured without the rejection tab (identified by a catalog number prefix BR, BRD and CHNT) are available for replacement purposes in older interiors. All 120/240V breakers, both 1-inch (25.4 mm), 1/2-inch (12.7 mm) and 3/4-inch (19.1 mm) per pole meet the requirement of Federal Specifications W-C 375B/ Gen Type 1. Canadian Standards Association Listing All single-pole and two-pole, 120/240V breakers, both 1-inch (25.4 mm), 1/2-inch (12.7 mm) and 3/4-inch (19.1 mm) per pole, 225A maximum, are listed as Certified by the Canadian Standards Association, Guide No. 69-11.19, Class 1432, File 18328. Underwriters Laboratories Listing Lighting and Appliance Panelboards All grounding bars manufactured comply with Underwriters Laboratories standards and are listed under Guide No. DHJR, File E31424, Volume W, Section 17. Lighting and appliance branch circuit panelboards are defined in NEC (Article 384) as “One having more than 10 percent of its overcurrent devices rated 30A or less for which neutral connections are provided.” Article 384 also limits the number of overcurrent devices (branch circuit poles) to a maximum of 42 in any one cabinet. When the 42 poles are exceeded, two or more separate panels are required. All circuit breakers 10A and larger comply with the Underwriters Laboratories “Standard for Branch Circuit and Service CircuitBreakers” UL 489; Guide No. 60 10.2 File E31424, and “Requirements for Wire Connectors and Soldering Lugs,” UL 486B, Guide No. 461 10-C File E7830. For more details and engineering drawings, see BR.31.02.S.E. 1 1 1 1 1 1 1 1 1 1 1 All Eaton breakers where marked, are suitable for use with 60/75ºC rated wire, unless otherwise specified. 1 1 All devices comply with the 22 kAIC–10 kAIC UL series connected components File DKSY2 of the Recognized Components Index. 1 1 1 Product Selection 1 1 Type CH Loadcenter Interior Assemblies—Copper Bus Ampere Rating Maximum Number 1-Inch (24.5 mm) Spaces Single Poles UL File Reference Main Terminal Size (Per Phase) Standard Package Quantity Catalog Number Single-Phase Single Row Breaker Mounting—120/240 Vac, Three-Wire 1 1 70 2 2 E8741 (1) #8–#2 AWG Cu/Al 1 CH9MB270 125 2 2 E8741 (1) 2/0–#6 AWG Cu/Al 20 CH2L125INT 1 1 Single-Phase Double Row Breaker Mounting—120/240 Vac, Three-Wire 125 4 4 E8741 (1) 2/0–#14 AWG Cu/Al 20 CH4L125INT 125 8 8 E8741 (1) 2/0–#6 AWG Cu/Al 20 CH8L125INT 125 12 12 E8741 (1) 2/0–#6 AWG Cu/Al 20 CH12L125INT 125 16 16 E8741 (1) 2/0–#6 AWG Cu/Al 20 CH16L125INT 200 12 12 E8741 (1) 300 kcmil–#4 AWG Cu/Al 20 CH12L200INT 200 16 16 E8741 (1) 300 kcmil–#4 AWG Cu/Al 10 CH16L200INT 225 24 24 E8741 (1) 300 kcmil–#4 AWG Cu/Al 10 CH24L225INT 225 32 32 E8741 (1) 300 kcmil–#4 AWG Cu/Al 10 CH32L225INT 225 42 42 E8741 (1) 300 kcmil–#4 AWG Cu/Al 10 CH42L225INT 1 1 Three-Phase Double Row Breaker Mounting—208Y/120 Vac, Four-Wire—240 Vac, Three-Wire—120/240 Vac, Four-Wire Delta 125 12 12 E8741 (1) 2/0–#6 AWG Cu/Al 10 CH12L3125INT 125 18 18 E8741 (1) 2/0–#6 AWG Cu/Al 10 CH18L3125INT 125 24 24 E8741 (1) 2/0–#6 AWG Cu/Al 10 CH24L3125INT 225 24 24 E8741 (1) 300 kcmil–#4 AWG Cu/Al 10 CH24L3225INT 225 30 30 E8741 (1) 300 kcmil–#4 AWG Cu/Al 10 CH30L3225INT 225 42 42 E8741 (1) 300 kcmil–#4 AWG Cu/Al 10 CH42L3225INT Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-89 1 1 1 1 1 1 1.3 1 BR Loadcenter Interior Assembly 1 Loadcenters and Circuit Breakers Loadcenter Interiors/OEM Loadcenters Type BR Loadcenter Interior Assemblies—Aluminum Bus Ampere Rating Maximum Number 1-Inch (24.5 mm) Spaces Single Poles UL File Reference Main Terminal Size (Per Phase) Standard Package Quantity Catalog Number Single-Phase Single Row Breaker Mounting—120/240 Vac, Three-Wire 1 1 1 70 2 4 E8741 (1) #8–#2 AWG Cu/Al 20 24INT70B 125 2 4 E8741 (1) 1/0–#14 AWG Cu 2/0–12 AWG All 20 24INT125B 125 6 12 E52977 (1) 2/0–#14 AWG Cu/Al 20 612INT125SRB 48INT125B Single-Phase Double Row Breaker Mounting—120/240 Vac, Three-Wire 1 125 4 8 E8741 (1) 2/0–#14 AWG Cu/Al 20 125 6 12 E8741 (1) 2/0–#14 AWG Cu/Al 20 612INT125B 1 125 8 16 E8741 (1) 2/0–#14 AWG Cu/Al 20 816INT125B 125 12 12 E52977 (1) 2/0–#14 AWG Cu/Al 20 1212INT125B 125 12 24 E52977 (1) 2/0–#14 AWG Cu/Al 20 1224INT125B 1 125 16 24 E52977 (1) 2/0–#14 AWG Cu/Al 20 1624INT125B 125 20 24 E52977 (1) 2/0–#14 AWG Cu/Al 10 2024INT125B 1 125 24 24 E52977 (1) 2/0–#14 AWG Cu/Al 10 2424INT125B 200 8 16 E52977 (1) 300 kcmil–#1 AWG Cu/Al 20 816INT200B 1 200 12 24 E52977 (1) 300 kcmil–#1 AWG Cu/Al 20 1224INT200B 1 200 30 40 E52977 (1) 300 kcmil–#1 AWG Cu/Al 10 3040INT200B 225 42 42 E52977 (1) 300 kcmil–#1 AWG Cu/Al 10 4242INT225B 1 Three-Phase Double Row Breaker Mounting—208Y/120 Vac, Four-Wire—240 Vac, Three-Wire— 120/240 Vac, Four-Wire Delta 1 125 12 24 E52977 (1) 2/0–#8 AWG Cu/Al 10 1224INT3125B 150 18 36 E52977 (1) 300 kcmil–#2 AWG Cu/Al 10 1836INT3150B 1 150 24 42 E52977 (1) 300 kcmil–#2 AWG Cu/Al 10 2442INT3150B 200 30 42 E52977 (1) 300 kcmil–#2 AWG Cu/Al 10 3042INT3200B 1 225 42 42 E52977 (1) 300 kcmil–#2 AWG Cu/Al 10 4242INT3225B Main Terminal Size (Per Phase) Standard Package Quantity Catalog Number 1 1 Type BR Loadcenter Interior Assemblies—Copper Bus 1 Ampere Rating 1 Maximum Number 1-Inch (24.5 mm) Spaces Single Poles UL File Reference Single-Phase Double Row Breaker Mounting—120/240 Vac, Three-Wire 1 1 125 8 16 E5297 (1) 2/0–#14 AWG Cu/Al 20 816INT125BC 125 12 12 E5297 (1) 2/0–#14 AWG Cu/Al 20 1212INT125BC 200 12 24 E5297 (1) 300 kcmil–#1 AWG Cu/Al 20 1224INT200BC Three-Phase Double Row Breaker Mounting—208Y/120 Vac, Four-Wire—240 Vac, Three-Wire— 120/240 Vac, Four-Wire Delta 1 1 125 12 24 E52977 (1) 2/0–#8 AWG Cu/Al 10 1224INT3125BC 200 12 24 E52977 (1) 300 kcmil–#2 AWG Cu/Al 10 1224INT3200BC 1 1 1 1 1 1 1 V1-T1-90 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com Loadcenters and Circuit Breakers Loadcenter Interiors/OEM Loadcenters 1.3 Neutral Assemblies Number of Terminals Ampere Rating UL File Rating Main Incoming Terminal Wire Size Range 60°C or 75°C 125 E52977 125 1 Dimensions–Inches (mm) #14–4 AWG Cu/Al #6–1/0 AWG Cu #6–2/0 AWG Al Standard Package Quantity #6–1/0 AWG Cu #6–2/0 AWG Al 10 — E52977 #6–1/0 AWG Cu #6–2/0 AWG Al 17 125 E52977 #6–1/0 AWG Cu #6–2/0 AWG Al 225 E52977 225 E52977 125 — 1 Figure Overall Length A Mounting B Catalog Number 20 1 5.938 (150.83) 5.400 (137.16) 10NEU125B 1 — 20 1 8.388 (213.06) 7.850 (199.40) 17NEU125B 1 20 — 20 1 9.438 (239.73) 8.900 (226.06) 20NEU125B 1 #1–300 kcmil Cu/Al 24 1 20 2 10.913 (277.19) 10.300 (261.62) 24NEU225B 1 #1–300 kcmil Cu/Al 35 1 20 2 15.813 (401.65) 15.200 (386.08) 35NEU225B — 4 2 1 3 2.266 (57.56) 0.594 (15.09) BINA Figure 1 1 1 Figure 2 A .269 (6.83) A .344 (8.74) B .844 (21.44) C Lof Mounting Hole B .269 (6.83) .844 (21.44) 1.750 (44.45) C Lof Mounting Hole 1 1 1 1 1 2.360 (59.94) 2.860 (72.64) 2.360 (59.94) 1 Figure 3 .120 (3.05) A .250 (6.35) .182 Diameter (4.62) C Lof Mounting Hole 1.182 (30.02) .750 (19.05) .688 (17.47) .156 (3.96) C L of Mounting Hole 1 1 1 1.750 (44.45) 1.187 (30.15) B 1 1 .344 (8.74) 1 2.000 (50.80) 1 1 1 1 1 1 1 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-91 1.3 Loadcenters and Circuit Breakers Loadcenter Interiors/OEM Loadcenters 1 Add-on Lugs for Neutral Assemblies 1 Description Wire Size Range Cu/Al 60°C or 75°C Ordering Quantity 1 Catalog Number #2/0 maximum 1 NL20 #3/0 maximum 1 NL30 300 kcmil maximum 1 NL300 Length Inches (mm) Ordering Quantity 1 Catalog Number dssssds 2.54 (64.5) 1 GBK5 2 dssssdsj 3.59 (91.2) 1 GBK520 2 dssssdssssss 4.29 (109.0) 1 GBK10 2 1 dssssdssssssj 5.34 (135.6) 1 GBK1020 2 1 4.61 (117.1) 1 GBK13 2 dssssdssssssssss 5.69 (144.5) 1 GBK14 2 dssssdssssssssssj 6.74 (171.2) 1 GBK1420 2 Neutral/ground lug Add-on neutral or ground lug 1 1 1 1 GBK14 Description (See Legend) 1 BRGBK39512 f d f f f k f d f k f f f 1 Ground Bar Kits 1 1 GBK21 2 1 GBK2120 2 5.78 (146.8) 1 BRGBK39512 34 f k f d f k f f f k f d f k f f f k f 1 dssssdsssssssssssssssss 8.14 (206.8) dssssdsssssssssssssssssj 9.19 (233.4) 1 Ground Bar Legend s (3) #14–10 Cu/Al or (1) #14–4 Cu/Al j (1) #6–2/0 Cu/Al (1) #14–1/0 Cu/Al or (3) #14–10 Cu/Al (1) #14–6 Cu/Al or (2) #14–12 Cu/Al d Mounting Hole fk 1 1 1 Notes 1 Must be purchased in multiples of ordering quantities indicated. 2 Distance between mounting holes is 1.75 inches (44.5 mm). 3 For single- and three-phase 400 and 600A applications. 4 Distance between mounting holes is 2.34 inches (59.5 mm). 1 1 1 1 1 1 1 1 1 1 1 1 1 1 V1-T1-92 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com Loadcenters and Circuit Breakers Enclosed Breakers 1.4 Contents Enclosed Breakers Description Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . Page V1-T1-94 1 1 1 1 1 1 1 1 1 1 Product Overview Product Description Eaton enclosed breakers offer all the advantages of circuit breakers packed in an enclosure for 240 Vac applications and include a wide range of accessories. ● ● ● 100–225A, 240 Vac maximum NEMA 1 general purpose— surface or flush mounting NEMA 3R rainproof surface mounting 1 Standards and Certifications ● ● ● 1 UL 489 CSA 22.2 NEMA 250 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-93 1.4 Loadcenters and Circuit Breakers Enclosed Breakers 1 Product Selection 1 Single-Phase Circuit Breaker Enclosures—10/25/35 kAIC 1 1 Circuit Breaker Unit Enclosures Type ECB Circuit Breaker Enclosure—Includes Lug Kit Main Ampere Rating Type of Circuit Breaker Wire Size Range Cu/Al 60°C or 75°C Catalog Number — CSR (included) 1 4 ECB150RB 567 — 2 4 ECB200RB 567 CSH 4 ECB225F 367 CSR 3 4 ECB225S 367 CSR 3 4 ECB225R 3567 Mounting Single-Phase Three-Wire—240 Vac Maximum 1 150 1 Outdoor 200 Outdoor 225 Indoor 1 Flush Indoor Surface Outdoor 1 1 Unit Enclosure Type CSR2200N 1 Circuit Breakers 120/240 Vac—25 kAIC For Use in Type ECB Enclosures Ampere Rating 1 — Two-Pole Breakers Catalog Number Wire Size Range Cu/Al 60°C or 75°C for Line Terminals 10 kAIC 25 kAIC 100 #2–300 kcmil — CSR2100N 125 #2–300 kcmil BW2125 CSR2125N 1 150 #2–300 kcmil BW2150 CSR2150N 175 #2–300 kcmil BW2175 CSR2175N 1 200 #2–300 kcmil BW2200 CSR2200N 225 #2–300 kcmil BW2225 CSR2225N 1 1 CSR (included) BW, CSR 3, Wire Data Wire/Application Maximum Wire Size Maximum Ampere Rating Aluminum—standard 250 kcmil 200 Aluminum—service entrance 250 kcmil 225 Copper—standard and service entrance 250 kcmil 225 Shunt Trips, Auxiliary and Alarm Contacts Description Catalog Number Suffix Adder 8 Shunt Trip for Types BW/CSR 1 Shunt Trips Catalog Number Suffix Adder 8 1 Type 1 CSR 12 SR12 CSR 24 SR24 CSR 120 SR01 Volts 12V SR12 24V SR24 120V SR01 Auxiliary Contact for Types BW/CSR 1 1NO and 1NC AL1 2NO and 2NC AL2 Alarm Contacts for Types BW/CSR Types BW/CSR 1 Lug Kit for Replacement Purposes Only For Use in Type ECB Enclosures 1 Ampere Rating 1 225 1 1 1 1 1 Description For use on 125, 150, 175, 200 and 225A breakers Wire Size Range Cu/Al 60°C or 75°C Catalog for Line Terminals Number #2–300 kcmil MCBK225 Alarm Contacts for Type GFCB (Single-Pole) Alarm contact for GFCB (single-pole) W1 1NO and 1NC W2 Notes 1 CSR2150N factory-installed circuit breaker. 2 CSR2200N factory-installed circuit breaker. 3 Order circuit breaker separately. 4 Wire size is determined by the circuit breaker installed in enclosure. Maximum wire size and ampere rating is determined by Wire Data table above. 5 Rainproof panels are furnished with hub closures plates. For rainproof hubs, refer to Page V1-T1-25. 6 One ground lug accepting (1) #14 –#2 is factory installed. Also, there are pre-drilled holes to accept a GBK5 ground bar. 7 Approved for service entrance. 8 Add suffix indicated to end of breaker catalog number. Box sizes Pages V1-T1-27 and V1-T1-28. 1 1 1 V1-T1-94 CR1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com 1.4 Loadcenters and Circuit Breakers Enclosed Breakers Single-Phase and Three-Phase Circuit Breaker Enclosures—10/25 kAIC ECC225S 1 1 Type ECC Circuit Breaker Enclosure—Order Type CC Circuit Breaker Separately Main Ampere Rating Unit Enclosure Type Mounting Type Circuit Breaker Type Wire Size Range Cu/Al 60°C or 75°C Catalog Number 1 Single- and Three-Phase—240 Vac Maximum 1 225 Indoor Flush CC/CCV/CCH 5 ECC225F 123 225 Indoor Surface CC/CCV/CCH 5 ECC225S 123 CC/CCV/CCH 5 ECC225R 1234 225 Outdoor — 1 1 1 CCV2200 Circuit Breaker 240 Vac for Use in Type ECC Enclosures Ampere Rating Wire Size Range Cu/Al 60°C or 75°C for Line Terminals Type CCV and CC 10 kAIC Catalog Number Type CCVH/CCH 25 kAIC Catalog Number 8 Two-Pole 100 #4–4/0 CCV2100 CCVH2100 125 CCV2125 CCVH2125 150 CCV2150 CCVH2150 175 #2/0–300 kcmil CCV2175 CCVH2175 200 CCV2200 CCVH2200 225 CCV2225 CCVH2225 Three-Pole 100 CC3100 CCH3100 125 #4–4/0 CC3125 CCH3125 150 CC3150 CCH3150 175 #2/0–300 kcmil CC3175 CCH3175 200 CC3200 CCH3200 225 CC3225 CCH3225 1 Wire/Application Chart Wire/Application Maximum Wire Size Maximum Ampere Rating 1 Aluminum—standard 250 kcmil 200 Aluminum—service entrance 250 kcmil 225 1 Copper—standard and service entrance 250 kcmil 225 Notes 1 Order circuit breaker separately. 2 One ground lug accepting (1) #14–#2 is factory installed. Also, there are pre-drilled holes to accept a GBK5 ground bar. 3 Approved for service entrance. 4 Rainproof panels are furnished with hub closures plates. For rainproof hubs, refer to Page V1-T1-65. 5 Wire size is determined by the circuit breaker installed in enclosure. Maximum wire size and ampere rating is determined by the Wire/Application Chart. 6 CCV breakers are two-pole only. 7 Add suffix indicated to end of breaker catalog number. 8 Series ratings are not available for CCH or CCVH breakers. Box sizes Pages V1-T1-66 through V1-T1-68. 1 1 1 1 1 1 1 1 1 Shunt Trips and Auxiliary Contacts 6 Description 1 Volts Catalog Number Suffix Adder 7 1 CC 12 DC SR12 1 CC 24 DC SR24 CC 120 AC SR01 CC 208 AC SR08 CC 240 AC SR02 CCV 48–127 AC/48–60 DC SR01 CCV 9–24 AC/12–24 DC SR24 Type Shunt Trip 1 1 1 1 Auxiliary Contact CC 1NO and 1NC — 1 AL1 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-95 1.5 1 Loadcenters and Circuit Breakers Classified Circuit Breakers Contents Classified Breakers Description 1 Page Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1 V1-T1-97 V1-T1-99 V1-T1-99 V1-T1-100 1 1 1 1 1 1 1 1 1 1 1 1 1 Product Description Eaton UL classified Replacement Circuit Breakers are available in both 3/4-inch Type CHQ and 1-inch Type CL, single- and two-pole configurations. These breakers are classified as direct replacements by Underwriters Laboratories. In addition to a UL listing, they also come with a 15-year warranty. 1 1 Specified vs. UL Classified Testing Specified breakers are listed by the manufacturer of the panelboard for use in a particular panel. This doesn’t mean that the panelboard manufacturer produced the specified breaker; it merely means that the panelboard manufacturer has tested the breaker in the panel. In fact, through the years, Eaton has manufactured thousands of breakers for other panelboard manufacturers. Classified breakers are tested extensively in numerous General Electric®, Siemens®, Murray®, Thomas & Betts®, Square D®, and Crouse-Hinds® panels. The tests are conducted with witnesses from Underwriters Laboratories Inc. and involve short-circuit, temperature, and insertion/withdrawal applications. This level of testing ensures that the breakers meet identified standards and have been found suitable by UL for the specified purpose. UL classified breakers are produced by one manufacturer for use in place of the breakers specified on the panelboard. Like specified breakers, UL classified breakers have been tested in the panels for which they are approved. 1 1 1 1 Understanding Classified Breaker Terminology Definitions Specified circuit breaker— each manufacturer lists the brands of circuit breakers that can be used in their panelboards. Often, manufacturers will not list competitors as specified, even though they are suitable replacements. Classified circuit breaker— a breaker that is considered suitable, by a qualified thirdparty organization, for use in another manufacturer’s panelboard. Listed breaker—the listing of a circuit breaker is by an independent third party. Eaton classified breakers are listed by UL. Labeled breaker—a breaker with a label affixed by an independent third party. 1 1 1 1 1 1 1 V1-T1-96 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com Loadcenters and Circuit Breakers Classified Circuit Breakers 1.5 Product Selection 1 Type CHQ Replacement Breakers for Square D Type QO Loadcenters 1 10 kAIC, 120 and 120/240 Vac CHQ120 CHQ230 1 Type CHQ Classified Breakers 3/4-Inch (19.1 mm) per Pole 120 or 120/240 Vac, 10 kAIC Single-Pole 120/240 Vac Requires One 3/4-Inch (19.1 mm) Space 10 per Shelf Carton Two-Pole 120/240 Vac Common Trip Requires Two 3/4-Inch (19.1 mm) Spaces 5 per Shelf Carton Catalog Number Catalog Number CHQ115 CHQ215 CHQ120 CHQ220 25 CHQ125 CHQ225 30 CHQ130 CHQ230 35 CHQ135 CHQ235 40 CHQ140 CHQ240 45 CHQ145 CHQ245 50 CHQ150 CHQ250 60 — CHQ260 Ampere Rating Wire Size Range Cu/Al 60ºC or 75°C 15 (1) #14–8 (2) #14–10 20 1 1 1 1 1 1 1 1 1 1 Type CHQ Ground Fault and Arc Fault Replacement Breakers for Square D Type QO Loadcenters 1 10 kAIC, 120 and 120/240 Vac CHQ115GF CHQ220GF 1 Type CHQ Ground Fault Breakers—5 Milliampere— 3/4-Inch (19.1 mm) per Pole, 10 kAIC Single-Pole 120 Vac Requires One 3/4-Inch (19.1 mm) Space 10 per Shelf Carton Two-Pole 120/240 Vac Common Trip Requires Two 3/4-Inch (19.1 mm) Spaces 5 per Shelf Carton Catalog Number Catalog Number CHQ115GF CHQ215GF CHQ120GF CHQ220GF 25 CHQ125GF CHQ225GF 30 CHQ130GF CHQ230GF 35 — CHQ235GF 40 — CHQ240GF 45 — CHQ245GF 50 — CHQ250GF Ampere Rating Wire Size Range Cu/Al 60ºC or 75°C 15 (1) #14–8 (2) #14–10 20 1 1 1 1 1 1 1 1 1 1 Type CHQ Surge Arrester 1 Catalog Number CHQSA 1 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-97 1.5 1 Loadcenters and Circuit Breakers Classified Circuit Breakers Type CL Replacement Breakers for Square D HOMELINE, General Electric, Crouse-Hinds, Thomas & Betts, Murray and ITE®/Siemens Loadcenters 1 1 CL_ Type CL Breakers, 1-Inch (25.4 mm) per Pole, 10 kAIC 1 Ampere Rating Wire Size Range Cu/Al 60°C or 75°C Single-Pole 120/240V Requires One 1-Inch (25.4 mm) Space 10 per Shelf Carton Catalog Number 15 #14–4 CL115 CL215 1 20 #14–4 CL120 CL220 25 #14–4 CL125 CL225 1 30 #14–4 CL130 CL230 1 35 #14–4 CL135 CL235 40 #14–4 CL140 CL240 45 #14–4 CL145 CL245 50 #14–4 CL150 CL250 1 1 1 Two-Pole 120/240V Common Trip Requires Two 1-Inch (25.4 mm) Spaces 5 per Shelf Carton Catalog Number 1 1 CL_AF Type CL Classified Arc and Ground Fault Breakers (5 Milliampere), 1-Inch (25.4 mm) per Pole, 10 kAIC 1 1 Ampere Rating 1 Wire Size Range Cu/Al 60°C or 75°C Single-Pole 120/240V Requires One 1-Inch (25.4 mm) Space 1 per Shelf Carton Catalog Number Arc Fault Breakers 1 15 #14–4 CL115AF 1 20 #14–4 CL115CAF 20 #14–4 CL120AF 1 20 #14–4 CL120CAF Ground Fault Breakers 1 1 15 #14–4 CL115GF 20 #14–4 CL120GF 30 #14–4 CL130GF 1 1 CLR_ Type CL Classified Latching Remote Control Smart Breakers™, 1-Inch (25.4 mm) per Pole, 10 kAIC 1 1 1 1 1 Ampere Rating Wire Size Range Cu/Al 60°C or 75°C Single-Pole 120V Requires One 1-Inch (25.4 mm) Space 10 per Shelf Carton Catalog Number 15 (2) #14–10 CLRP115 CLRP215 20 (2) #14–10 CLRP120 CLRP220 25 (1) #8–6 CLRP125 CLRP225 30 (1) #8–6 CLRP130 CLRP230 Two-Pole 120/240V Common Trip Requires Two 1-Inch (25.4 mm) Spaces 5 per Shelf Carton Catalog Number 1 1 1 V1-T1-98 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com Loadcenters and Circuit Breakers Classified Circuit Breakers Accessories 1.5 Technical Data CHQ Breaker Accessories Description Catalog Number Breaker handle lock CHLO Arc Fault Application Notes An arc fault circuit interrupter is a device intended to provide protection from the effects of arc faults by recognizing characteristics unique to arcing and by functioning to de-energize the circuit when the arc fault is detected. As of January 1, 2002, the National Electrical Code (NEC) requires all branch circuits that supply 125V, single-phase, 15 and 20A receptacle outlets installed in dwelling unit bedrooms shall be protected by an arc fault circuit interrupter(s). This includes ceiling lighting (recessed, ceiling fans, etc.) as well as smoke detectors and all other bedroom outlets. The 2005 NEC introduced the application of the Combination Type AFCI for bedroom circuits required as of January 1, 2008. The 2008 NEC expands this application to other living areas. 1 Ground Fault Application Notes 1 Single-pole GFCBs are designed for use in two-wire, 120 Vac circuits. Drawing on Page V1-T1-100 shows a typical wiring configuration. 1 1 1 Two-pole GFCBs are designed for use in threewire, 120/240 Vac circuits, 120 Vac multiwire circuits employing common, neutral and two-wire, 240 Vac circuits obtained from a 120/240 Vac source. 1 1 1 1 Drawings on Page V1-T1-100 illustrate typical wiring configurations for 120/240 Vac multiwire circuits. 1 1 Drawing on Page V1-T1-100 depicts a 240 Vac, two-wire circuit. Note the “panel neutral” conductor connects to the neutral bar, even though the neutral is not included in the load circuit. This connection is necessary to supply a 120 Vac power source to the ground fault sensing circuit. 1 1 1 1 1 The figures are shown with a 120/240 Vac, single-phase, three-wire power source, ut are also applicable to a 120/208 Vac, three-phase, four-wire power supply. For all figures, the electrical operation of the GFCB is not affected by the equipment ground. 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com V1-T1-99 1.5 1 1 1 Loadcenters and Circuit Breakers Classified Circuit Breakers Wiring Diagrams Single-Pole 120V Load Application Sourced by 120/240 Vac Two-Pole 240V Load Application Sourced by 120/240 Vac 120/240 Vac Source N A B 120/240 Vac Source N A B 1 1 1 1 1 Neutral Neutral 1 1 1 Neutral Equipment Ground Two-Pole Shared Neutral with Duplex Receptacle Application 120/240 Vac Source N A B 120/240 Vac Source N A B Line B Line B Line A Two-Pole Two-Pole Neutral Neutral Two 120V Duplex Receptacles Neutral Neutral 120V Duplex Receptacle (With Line Side Jumper Removed) Equipment Ground Equipment Ground Line A Single-Pole 120V Duplex Receptacle Application Two-Pole 120V Duplex Receptacle Application 120/240 Vac Source N A B 120/240 Vac Source N A B 1 Line B Line B 1 1 240V Duplex Receptacle Line A Two-Pole Shared Neutral with Multi-Duplex Receptacle Application 1 1 120V Duplex Receptacle Equipment Ground 1 1 Two-Pole Single-Pole 1 1 Line B Line B 1 Line A Two-Pole Single-Pole Neutral Neutral 120V Duplex Receptacle Neutral Neutral 1 120V Duplex Receptacle (With Line Side Jumper Removed) 1 1 1 Two-Pole 120V Multi-Duplex Receptacle Application Two-Pole 240V Duplex Receptacle Application 120/240 Vac Source N A B 120/240 Vac Source N A B 1 1 1 Line B Line B Two-Pole Two-Pole Neutral Neutral 1 1 Two 120V Duplex Receptacles Line A Neutral Line A V1-T1-100 Volume 1—Residential and Light Commercial CA08100002E—June 2014 www.eaton.com 240V Duplex Receptacle Surge Protection Surge Protection Devices 2.1 Surge Protection Devices and Lightning Arresters Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Application Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Standards and Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T2-2 V1-T2-2 V1-T2-3 V1-T2-4 2 2 2 2 Learn Online 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com V1-T2-1 2.1 2 Surge Protection Surge Protection Devices and Lightning Arresters Contents Surge Protection Devices Description 2 Page Surge Protection Devices and Lightning Arresters Standards and Certifications . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . 2 V1-T2-3 V1-T2-4 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Product Description Application Description Due to the evolution of electronics and microprocessors in the home, there is a continuous challenge to provide quality (clean) power for electronic loads such as appliances, computers/home office and entertainment systems. Surges caused by lightning, utility grid switching and other sources travel on current carrying conductors throughout the home, which can effect and destroy sensitive electronic loads. Two-Stage Protection Eaton offers a comprehensive family of surge products for use at service entrance. These products can help protect sensitive electronics against the damaging effects of surges. 2 2 Service Entrance Surge Protection Eaton’s service entrance surge protection units provide premier surge protection for AC power at the service entrance. These products provide protection for residential electrical equipment by reducing power surges to an acceptable level for surge strips to handle at the point of use. UL 1449 3rd Edition Type 1 and Type 2 Surge Protection ● Type 1 Surge Protective Device (SPD)— Permanently connected Type 1 SPDs are intended for installation between the secondary of the service transformer and the line side of the service equipment overcurrent device, as well as the load side, including watt-hour meter socket enclosures and are intended to be 2 2 2 2 2 2 V1-T2-2 installed without an external overcurrent protective device. Type 1 devices are dual-rated for Type 2 applications as well, providing the highest ratings available for installation at the service entrance ● Eaton’s CHSPT1 products provide Type 1 surge protection in accordance with UL® 1449 3rd Edition. These units can be universally mounted outside any manufacturer’s primary service equipment Two stages of surge suppression are recommended to provide the best protection for electronic equipment. Two-stage surge suppression should be provided for all cables entering a home, including power, Internet, coaxial and telephone. ● Type 2 Surge Protective Device—Permanently connected Type 2 SPDs are intended for installation on the load side of the service equipment overcurrent device, including SPDs located at the branch panel ● CHSPT2 products provide Type 2 surge protection in accordance with UL 1449 3rd Edition. These units can be mounted outside of any manufacturer’s loadcenter or inside an Eaton Surge/Surge Ready loadcenter. Eaton also offers accessories to the CHSPT2 line for telephone and cable protection. Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com ● Factory-Installed Surge Protection—Eaton’s loadcenters with factoryinstalled surge protection include a CHSPT2ULTRA and a two-pole 50A circuit breaker. These loadcenters increase the effectiveness of surge protection due to reduced lead length. A modified deadfront allows for easy viewing of indicating lights for status indication Surge Panel ● Surge Ready Loadcenter—The SurgeReady loadcenter provides a mounting provision for the CHSPT2ULTRA. This loadcenter has a modified deadfront to allow for viewing of indicating lights. Surge Protection Surge Protection Devices and Lightning Arresters 2.1 Two-Stage Protection ● 1 2 CHSP installed at the service entrance panel. SurgeTrap™ surge traps and strips located where sensitive electronics are plugged in. Plug-On Surge Protection ● Type CHSA—For use on single-phase 120/240 Vac systems. The CHSA easily plugs into a single-phase Type CH loadcenter and occupies two 3/4-inch (19.1 mm) pole spaces, similar to a two-pole Type CH breaker. When installed properly, it provides surge protection for the entire loadcenter. If internal components are damaged, the CHSA LED visual indicators will signal the need for a replacement. This device is suitable for service entry locations when installed in accordance with NEC® guidelines. ● Type BRSURGE—For use on single-phase 120/240 Vac systems. This easily plugs into a single-phase Type BR loadcenter and occupies two 1-inch (25.4 mm) pole spaces similar to a two-pole Type BR breaker. When installed properly, it provides surge protection for the entire loadcenter. If internal components are damaged, the BRSURGE LED visual indicators will signal the need for replacement. This device is suitable for service entry locations when installed in accordance with NEC guidelines. This unit is also classified by UL for use in select GE, ITE/ Siemens, and CrouseHinds Panels. (Refer to Pub No. 5655B65H01 for additional details.) ● Type CHQSA—For use on single-phase, 120/240 Vac systems. This unit easily plugs into a Square D single-phase loadcenter Type QO® and occupies two 3/4-inch (19.1 mm) pole spaces similar to a two-pole Type QO breaker. When installed properly, it provides surge protection for the entire loadcenter. If internal components are damaged, the CHQSA LED visual indicators will signal the need for a replacement. This device is suitable for service entrance locations installed in accordance with NEC guidelines. This device is UL classified to be used in place of Square D Type QO surge arresters (refer to Pub-23974). Type BRSURGECSA— For use on single-phase 120/240 Vac systems. This easily plugs into a singlephase Type BR loadcenter and occupies two 1-inch (25.4 mm) pole spaces similar to a two-pole Type BR breaker. When installed properly, it provides surge protection for the entire loadcenter. If internal components are damaged, the BRSURGECSA LED visual indicators will signal the need for replacement. This device is suitable for service entry locations when installed in accordance with Canadian Electrical Code. This device is CSA® listed to be used in a Type BR loadcenter. Type 3 Point-of-Use Surge Protection Point-of-use surge strips are designed to offer premium surge protection for specific electronics while providing innovative features to enhance user convenience. Standards and Certifications ● ● ● ● ● ● 2 2 2 2 2 2 CHSPT1 Products: UL 1449 3rd Edition Type 1 CHSPT2 Products: UL/cUL® 1449 3rd Edition Type 2 CHSPTELE: UL 497A, cUL CHSPCABLE: UL 6500, cUL NEMA® 3R Enclosure for CHSPTELE and CHSPCABLE: UL 50 Enclosure BRSURGE, CHSA, BRSURGECSA, CHQSA: UL 1449 3rd Edition plug-in type; Type 2 SPD 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com V1-T2-3 2.1 2 Surge Protection Devices and Lightning Arresters Product Selection 2 SPD Type 1 CHSP Service Entrance Surge Protection—UL 1449 3rd Edition 2 Product Features ● Commercial grade AC power protection ● Type 1 surge device for installation before or after the main service disconnect ● Convenient mounting options—universal fit to any manufacturer’s equipment ● Clear, visible LED indication displaying status of the surge protector 2 2 2 2 Surge Protection Catalog Number Connection Enclosure Voltage Frequency Phase (Hz) MCOV 1 VPR 2 In 3 SCCR 4 Surge Current Capacity, Per Phase Rating 5 CHSPT1ULTRA CHSPT1ULTRA Permanently connected device NEMA 4 installed before or after the service disconnect overcurrent device. 100/200, 110/220, 120/240 Single 50/60 L-L 300, L-N 150 L-L 1000, 20 kA 200 kA L-N 600 50 kA CHSPT1MAX CHSPT1MAX Permanently connected device NEMA 4 installed before or after the service disconnect overcurrent device. 100/200, 110/220, 120/240 Single 50/60 L-L 300, L-N 150 L-L 1000, 20 kA 200 kA L-N 600 45 kA CHSPT1MICRO CHSPT1MICRO Permanently connected device NEMA 4 installed before or after the service disconnect overcurrent device. 100/200, 110/220, 120/240 Single 50/60 L-L 300, L-N 150 L-L 1000, 20 kA 200 kA L-N 600 36 kA CHSPT1-208Y CHSPT1-208Y Permanently connected device NEMA 4 installed before or after the service disconnect overcurrent device. 120/208 Threephase wye 50/60 L-L 300, L-N 150 L-L 1000, 20 kA 200 kA L-N 600 50 kA 2 2 2 2 2 2 2 2 2 2 2 2 2 Accessory for Type 1 CHSP Service Entrance Surge Protection 2 2 SP1DINRAILKIT Catalog Number Description SP1DINRAILKIT Mounting kit for wall or DIN rail installation. 2 2 2 Notes 1 MCOV: Maximum Continuous Operating Voltage that may be applied to the device per mode. 2 VPR: Voltage Protection Rating is the measured limiting voltage after a surge event. 3 I : Nominal Discharge Current is the current that the device can withstand for 15 impulses. n 4 SCCR: The amount of current the product can withstand under short-circuit conditions. 5 Surge Current Capacity: The maximum one time surge current rating per phase. 2 2 2 For warranty details, go to www.eaton.com/surgetrap. 2 2 V1-T2-4 Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com 2.1 Surge Protection Surge Protection Devices and Lightning Arresters SPD Type 2 CHSP Service Entrance Surge Protection—UL 1449 3rd Edition; cUL 2 Product Features ● AC power protection ● Universally connects to any manufacturer’s loadcenter (breaker box) ● Quick connect design—easy to mount telephone and cable protection modules ● LED status indication Catalog Number CHSPT2ULTRA CHSPT2MAX CHSPT2MICRO CHSPT2ULTRA CHSPT2MAX CHSPT2MICRO Connection Enclosure Voltage Can be attached to the outside of any manufacturer’s loadcenter (breaker box). This product should be connected on the load side of the loadcenter main service disconnect through a dedicated circuit breaker (follow NEC Guidelines). NEMA 4 Can be attached to the outside of any manufacturer’s loadcenter (breaker box). This product should be connected on the load side of the loadcenter main service disconnect through a dedicated circuit breaker (follow NEC Guidelines). NEMA 4 Can be attached to the outside of any manufacturer’s loadcenter (breaker box). This product should be connected on the load side of the loadcenter main service disconnect through a dedicated circuit breaker (follow NEC Guidelines). NEMA 4 Frequency Phase (Hz) MCOV 1 VPR 2 120/240 Single Vac rated line voltage 60 2 2 In 3 150V L-N, 600V L-N, 20 kA 300V L-L 1000V L-L, 800V N-G, 600V L-G SCCR 4 6 22 kA Surge Current Capacity, Per Phase Rating 5 108 kA (L1-N 54 kA, L1-G 54 kA, L2-N 54 kA, L2-G 54 kA) 2 2 2 2 2 120/240 Single Vac rated line voltage 60 150V L-N, 600V L-N, 10 kA 300V L-L 1000V L-L, 800V N-G, 600V L-G 22 kA 72 kA (L1-N 36 kA, L1-G 36 kA, L2-N 36 kA, L2-G 36 kA) 2 2 2 120/240 Single Vac rated line voltage 60 150V L-N, 600V L-N, 5 kA 300V L-L 1000V L-L, 800V N-G, 600V L-G 22 kA 36 kA (L1-N 18 kA, L1-G 18 kA, L2-N 18 kA, L2-G 18 kA) 2 2 2 2 Notes 1 MCOV: Maximum Continuous Operating Voltage that may be applied to the device per mode. 2 VPR: Voltage Protection Rating is the measured limiting voltage after a surge event. 3 I : Nominal Discharge Current is the current that the device can withstand for 15 impulses. n 4 SCCR: The amount of current the product can withstand under short-circuit conditions. 5 Surge Current Capacity: The maximum one time surge current rating per phase. 6 When used with a 50A two-pole circuit breaker, 10 kA when used with a 15A two-pole circuit breaker. 2 2 2 For warranty details, go to www.eaton.com/surgetrap. 2 2 2 2 2 2 2 2 2 2 2 2 Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com V1-T2-5 2.1 Surge Protection Devices and Lightning Arresters Accessories for CHSP Type 2 Service Entrance Protection 2 Catalog Number 2 2 Surge Protection Description Installation Surge Current Capacity DC Breakdown Voltage CHSPCABLE CHSPCABLE Quick Connect design—add additional telephone and AC protection modules; protects two quad shield cables; bi-directional Indoor installation; or rain-tight when used with recommended enclosure 10 kA per line 145V CHSPTELE CHSPTELE Quick Connect design—add additional AC and cable protection modules; protects four telephone lines Indoor installation; or rain-tight when used with recommended enclosure 20 kA per line 230V CHSPT23PACK CHSPT23PACK 3-Pack: CHSPT2ULTRA+CHSPTELE+CHSPCABLE; Surge protection for AC power, telephone and cable—see individual product features CHSP3RTELCABLE CHSP3RTELCABLE Raintight enclosure for CHSPTELE and CHSPCABLE; top or bottom feed; enclosure only, surge not included; accommodates up to two devices CHSPFMKIT CHSPFMKIT Flushmount kit for: CHSPT2ULTRA, CHSPT2MAX, CHSPT2MICRO, CHSPTELE, CHSPCABLE MSEGR2 MSEGR2 Outdoor communication grounding device; meets 2008 NEC requirements for intersystem bonding termination 2 Voltage 2 2 2 2 2 2 2 2 See individual product ratings 2 2 2 2 2 2 2 2 2 Note For warranty details, go to www.eaton.com/surgetrap. 2 2 2 2 2 2 2 2 2 V1-T2-6 Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com Ring 90–120 Vac/ Tone 48–52 Vdc Surge Protection Surge Protection Devices and Lightning Arresters Factory-Installed Surge Protection ● Includes a CHSPT2ULTRA and a two-pole 50A circuit breaker ● Increases the effectiveness of surge protection due to reduced lead length ● 2.1 2 A modified deadfront allows for easy viewing of indicating lights for status indication 2 2 2 2 Surge Installed Surge Installed Loadcenters 2 Cover Catalog Number Catalog Number Description CHSUR42N225L 1 42 ckt, 225A, convertible Surface CHSUR8LF CHSUR8LS 2 CHSUR8LF CHSUR8LS CHSUR42B200L2 1 42 ckt, 200A, main breaker CHSUR8LF CHSUR8LS CHSUR32N225K 1 32 ckt, 225A, convertible CHSUR8KF CHSUR8KS CHSUR32L225K 1 32 ckt, 225A, convertible 2 CHSUR8KF CHSUR8KS CHSUR42L225L2 1 Combination 42 ckt, 225A, convertible CHSUR32B200K 1 32 ckt, 200A, main breaker CHSUR8KF CHSUR8KS CHSUR32B150K 1 32 ckt, 150A, main breaker CHSUR8KF CHSUR8KS CHSUR32B100K 1 32 ckt, 100A, main breaker CHSUR8KF CHSUR8KS CHSUR24L125E 1 24 ckt, 125A, convertible 2 CHSUR8EF CHSUR8ES 1 24 ckt, 100A, main breaker CHSUR8EF CHSUR8ES BRSUR4040N200 40/40 ckt, 200A, convertible Cover included BRSUR4040L200 40/40 ckt, 200A, main lug Cover included BRSUR4040B200 40/40 ckt, 200A, main breaker Cover included BRSUR3040N200 30/40 ckt, 200A, convertible Cover included BRSUR3040L200 30/40 ckt, 200A, main lug Cover included BRSUR3040B200 30/40 ckt, 200A, main breaker Cover included CHSUR24B100E 2 2 2 2 2 2 2 2 2 2 Surge Ready Loadcenters ● Provides a mounting provision for CHSPT2ULTRA ● A modified deadfront allows for easy viewing of indicating lights Surge Ready 2 2 2 2 2 Surge Ready Loadcenters (Provision Only, CHSPT2ULTRA and Breaker Not Included) Cover Catalog Number Catalog Number Description Combination Surface CHEC42N225L 1 42 ckt, 225A, convertible CHSUR8LF CHSUR8LS CHEC42L225L 1 42 ckt, 225A, convertible 2 CHSUR8LF CHSUR8LS CHEC42B200L 1 42 ckt, 200A, main breaker CHSUR8LF CHSUR8LS CHEC32L225K 1 32 ckt, 225A, convertible 2 CHSUR8KF CHSUR8KS CHEC32N225K 1 32 ckt, 225A, convertible CHSUR8KF CHSUR8KS CHEC32B200K 1 32 ckt, 200A, main breaker CHSUR8KF CHSUR8KS CHEC32B150K 1 32 ckt, 150A, main breaker CHSUR8KF CHSUR8KS CHEC32B100K 1 32 ckt, 100A, main breaker CHSUR8KF CHSUR8KS CHEC24L125E 1 24 ckt, 125A, convertible 2 CHSUR8EF CHSUR8ES CHEC24B100E 1 24 ckt, 100A, main breaker CHSUR8EF CHSUR8ES 2 2 2 2 2 2 2 Notes 1 Order cover separately. 2 With main lugs installed. Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com 2 2 V1-T2-7 2.1 Surge Protection Devices and Lightning Arresters SPD Type 2 Plug-On Surge Protection—UL 1449 3rd Edition 2 Product Features ● Convenient surge protection for the loadcenter 2 2 2 Surge Protection Catalog Number Frequency Voltage Phase (Hz) MCOV 1 VPR 2 In 3 SCCR 4 Surge Current Capacity, Per Phase Rating 5 Description Connection BRSURGE BRSURGE UL for use in a single-phase Type BR loadcenter. This unit is classified by UL for use in select GE, ITE/Siemens and Crouse-Hinds panels (refer to Pub. No. 5655B65H01 for additional details). Plug on to the 120/240 Single loadcenter bus; see instructions. 60 L1-N 150V, L1-N 600V, 3k L-L 300V L-L 1000V 10k 18 kA CHSA CHSA UL and CSA for use in a Type CH loadcenter. Plug on to the 120/240 Single loadcenter bus; see instructions. 60 L1-N 150V, L1-N 600V, 3k L-L 300V L-L 1000V 10k 18 kA BRSURGECSA BRSURGECSA CSA for use in an Eaton Type BR loadcenter. Plug on to the 120/240 Single loadcenter bus; see instructions. 60 L1-N 150V, L1-N 600V, 3k L-L 300V L-L 1000V 10k 18 kA CHQSA CHQSA This device is UL classified to be used in place of Square D Type QO surge arresters (refer to Pub-23974). Plug on to the 120/240 Single loadcenter bus; see instructions. 60 L1-N 150V, L1-N 600V, 3k L-L 300V L-L 1000V 10k 18 kA 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Notes 1 MCOV: Maximum Continuous Operating Voltage that may be applied to the device per mode. 2 VPR: Voltage Protection Rating is the measured limiting voltage after a surge event. 3 I : Nominal Discharge Current is the current that the device can withstand for 15 impulses. n 4 SCCR: The amount of current the product can withstand under short-circuit conditions. 5 Surge Current Capacity: The maximum one-time surge current rating per phase. 2 2 2 For warranty details, go to www.eaton.com/surgetrap. 2 2 2 2 2 2 2 V1-T2-8 Volume 1—Residential and Light Commercial CA08100002E—September 2012 www.eaton.com Residential Standby Backup Power Solutions 3.1 Standby Generators Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Application Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Features, Benefits and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . Standards and Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Air-Cooled Generators. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Liquid-Cooled Generators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Sizing Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.2 V1-T3-4 V1-T3-5 V1-T3-6 V1-T3-6 V1-T3-8 V1-T3-10 Automatic Transfer Switches Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Application Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Standards and Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Standard Automatic Transfer Switches. . . . . . . . . . . . . . . . . . . . . . Green Automatic Transfer Switches— Featuring Active Load Management Technology . . . . . . . . . . . . . ATS Ready Loadcenter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.4 V1-T3-3 Portable Generators Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.3 V1-T3-2 V1-T3-2 V1-T3-2 V1-T3-2 V1-T3-3 V1-T3-3 V1-T3-11 V1-T3-11 V1-T3-12 V1-T3-13 3 3 3 3 3 3 3 3 3 3 3 V1-T3-13 3 V1-T3-13 3 V1-T3-14 V1-T3-15 Manual Transfer Switches Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Application Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Features, Benefits and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . Standards and Certifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Reference Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Manual Transfer Switches and Generator Panels Selection . . . . . . Power Inlet Boxes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 V1-T3-16 V1-T3-16 V1-T3-16 V1-T3-17 V1-T3-17 V1-T3-18 V1-T3-18 3 3 3 3 3 V1-T3-18 3 V1-T3-19 V1-T3-19 3 3 3 3 3 3 3 3 3 3 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T3-1 3.1 3 Residential Standby Backup Power Solutions Standby Generators Contents Standby Generator Systems Description 3 Page Standby Generators Catalog Number Selection . . . . . . . . . . . . . . . . Product Selection. . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Sizing Guidelines . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3 3 EGENX20A 3 V1-T3-3 V1-T3-3 V1-T3-5 V1-T3-6 V1-T3-6 EGEN70 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 Product Description A standby generator system is a package of equipment specifically designed to provide substitute electrical power to a residence in the event of a utility power outage. These systems are comprised of a generator, transfer switch and the connections necessary for installation. Eaton’s standby generator line consists of air-cooled and liquid-cooled models ranging from 8000 watts up to 150,000 watts. Air-Cooled Standby Eaton’s air-cooled generators range from 8 to 20 kW and these units are perfect for automatically backing up every circuit within a home such as air conditioner units, refrigerators, lighting, furnace fans, sump pumps and water pumps. 3 Application Description Eaton’s 14, 17 and 20 kW aircooled standby generators offer fully automatic operation and provide most homeowners with enough power for complete whole house comfort. These units all operate at ultra quiet 66 dB, or less, sound level. Liquid-Cooled Standby Eaton’s liquid-cooled generators feature automotive style engines that range from 22 to 150 kW of power output. These units run so quietly that you’ll forget that you own a generator until you need it. These units are available in steel or aluminum enclosures and are available in single- and three-phase in four voltages: 120/240V, singlephase; 120/208V, three-phase; 240V, three-phase; and 277/ 480V, three-phase. Standby generator systems are most often used in residential, agricultural and light commercial applications. Comfort and safety are key concerns of many homeowners who are dependent on an uninterrupted supply of electricity. The increase in our dependence on power is due in part to the popularity of home offices and in-home health care. Many regions of the United States experience periodic power outages due to extreme weather conditions such as ice and snowstorms, heat waves, tornadoes or hurricanes. Eaton highly recommends that any generator system be installed by a qualified electrician and/or generator installer. 3 3 3 3 3 3 V1-T3-2 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Features, Benefits and Functions Eaton’s generator systems offer a wide range of features. All systems feature: ● ● ● ● Powerful engines Reliable Eaton transfer switches and control systems using switching duty rated circuit breakers Weekly exercise function Automatic transfer systems feature automatic start/stop Standards and Certifications ● ● ● CSA, cUL® and UL 2200 listed and approved All transfer switches are UL 67 and UL 1008 listed as “Transfer Switches” All generators are UL 2200 listed Residential Standby Backup Power Solutions Standby Generators 3.1 Catalog Number Selection 3 3 Air-Cooled Generators EGENX 20 A Type Eaton generator EGENX Series Rated Power (LP/NG) 8 = 8/7 kW 11 = 11/10 kW 14 = 14/14 kW 17 = 17/16 kW 20 = 20/18 kW 3 3 Enclosure A = Aluminum Blank = Steel 3 3 3 Liquid-Cooled Generators 3 EGEN 22 A L A N kW Rating 22 60 25 70 27 80 30 100 36 130 45 150 48 Voltage Required A = Single-phase 120/240V G = Three-phase 208V J = Three-phase 240V K = Three-phase 480V Fuel Type N = Natural gas L = Liquid propane 3 Enclosure A = Aluminum S = Steel SCAQMD Compliance N = No Y = Yes 3 3 3 3 Product Selection 3 Air-Cooled Generators 3 Maximum Rated Rated Amperes Main Line Power kW at 240 Vac Circuit Breaker (LP/NG) (LP/NG) Amperes Enclosure Material Engine Size Number of Cylinders 8/7 33.3/29.2 35 Steel 410 cc 1 11/10 45.8/41.7 50 Steel 530 cc 14/14 58.3/58.3 60 Steel 17/16 70.8/66.6 65 17/16 70.8/66.6 20/18 83.3/75.0 3 Sound GFI SCAQMD Emissions Receptacle Compliant (dB at 7m) Limited Warranty (yrs) Catalog Number Liquid propane/ natural gas No Yes 62 5 EGENX8 3 2 Liquid propane/ natural gas No Yes 63 5 EGENX11 3 990 cc 2 Liquid propane/ natural gas No Yes 66 5 EGENX14 3 Steel 990 cc 2 Liquid propane/ natural gas Yes Yes 66 5 EGENX17 3 65 Aluminum 990 cc 2 Liquid propane/ natural gas Yes Yes 66 5 EGENX17A 3 90 Aluminum 990 cc 2 Liquid propane/ natural gas Yes Yes 66 5 EGENX20A 1 Fuel Type 3 3 Note 1 Includes No. EGENFASCIA as standard. 3 3 3 3 3 3 3 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T3-3 3.1 3 EGEN48ANAN 3 3 Residential Standby Backup Power Solutions Standby Generators Liquid-Cooled Generators 12 Catalog Number Prefix kW Rating Voltages Available EGEN22 22 A—120/240V, single-phase G—208V, three-phase SCAQMD Compliance Fuel Type Enclosure N—NG/LP field convertible (Default set up for NG) A—Aluminum Y—Yes (Default Compliant) N—NG/LP field convertible (Default set up for NG) S—Steel Y—Yes (Default Compliant) N—NG/LP field convertible (Default set up for NG) A—Aluminum Y—Yes (Default Compliant) N—NG/LP field convertible (Default set up for NG) S—Steel Y—Yes (Default Compliant) N—NG/LP field convertible (Default set up for NG) A—Aluminum Y—Yes J—240V, three-phase 3 EGEN25 25 3 A—120/240V, single-phase G—208V, three-phase J—240V, three-phase 3 EGEN27 27 A—120/240V, single-phase G—208V, three-phase 3 J—240V, three-phase EGEN30 30 3 A—120/240V, single-phase G—208V, three-phase J—240V, three-phase 3 EGEN36 36 A—120/240V, single-phase G—208V, three-phase 3 J—240V, three-phase N—No K—480V, three-phase 3 EGEN45 45 A—120/240V, single-phase G—208V, three-phase 3 N—NG/LP field convertible (Default set up for NG) S—Steel J—240V, three-phase Y—Yes N—No K—480V, three-phase 3 EGEN48 48 A—120/240V, single-phase 3 G—208V, three-phase 3 K—480V, three-phase N—NG/LP field convertible (Default set up for NG) A—Aluminum J—240V, three-phase EGEN60 60 A—120/240V, single-phase 3 G—208V, three-phase 3 K—480V, three-phase J—240V, three-phase EGEN70 70 A—120/240V, single-phase 3 G—208V, three-phase 3 K—480V, three-phase J—240V, three-phase EGEN80 80 A—120/240V, single-phase 3 G—208V, three-phase 3 K—480V, three-phase J—240V, three-phase EGEN100 3 100 A—120/240V, single-phase Y—Yes N—No N—Natural gas A—Aluminum Y—Yes L—Liquid propane S—Steel N—No N—Natural gas A—Aluminum Y—Yes L—Liquid propane N—Natural gas N—No A—Aluminum L—Liquid propane N—Natural gas Y—Yes N—No A—Aluminum Y—Yes G—208V, three-phase J—240V, three-phase 3 L—Liquid propane N—No K—480V, three-phase EGEN130 3 130 A—120/240V, single-phase N—Natural gas A—Aluminum Y—Yes G—208V, three-phase J—240V, three-phase 3 L—Liquid propane N—No K—480V, three-phase EGEN150 3 150 A—120/240V, single-phase N—Natural gas A—Aluminum Y—Yes G—208V, three-phase J—240V, three-phase 3 L—Liquid propane N—No K—480V, three-phase 3 Notes 1 All liquid-cooled models suitable for “optional” standby backup power only, as dictated by NEC Article 702/NFPA 70. Not suitable for legally required “emergency” applications as required by NEC Article 700/NFPA 110. 2 Models 70–150 kW include battery. For all other liquid-cooled models, battery must be furnished by others. 3 3 V1-T3-4 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Residential Standby Backup Power Solutions Standby Generators 3.1 Accessories 3 3 Generator Accessories—Air and Liquid-Cooled Generators Catalog Number 3 Air-cooled transportation cart EGENCART 3 Bisque paint kit for 2008 model lineup EGENPAINT Display shell—bisque color EGENSHELL Generator fascia for air-cooled models. Bisque color (included as standard on EGENX20A models) EGENFASCIA 3 Wireless remote monitor for air-cooled and liquid-cooled generators. Compatible with 2008 models or newer. USA only EGENMOBILE 3 EGENMOBILE adapter wire harness kit required for liquid-cooled generators only. 2008 models or newer. USA only EGENKIT Basic remote wireless monitor. Compatible with air/liquid-cooled models 8–150 kW. 2008 models or newer 5928CH Remote monitor adapter kit for liquid-cooled units only—must be ordered w/5928CH basic remote monitor. 2008 models or newer 5958CH 3 Cold weather kit for all air-cooled generator models (8–20 kW). Battery and crankcase warmer 6212CH 22, 27, 36, 45 and 60 kW (2.4L) cold weather kit 5630CH 3 25 and 30 kW (1.5L) cold weather kit 6175CH 100 and 130 kW (6.8L) cold weather kit 5633CH 48 (5.4L), 80 (4.6L) and 70 and 150 kW (6.8L) cold weather kit 5632CH 25 and 30 kW (1.6L) cold weather kit for models prior to February 2012 5629CH 48 kW (4.2L) cold weather kit for models prior to February 2012 5631CH 3 25 and 30 kW extreme cold weather kit 1.5L engine 6174CH 3 25 and 30 kW extreme cold weather kit 1.6L engine (prior to February 2012) 5615CH 22, 27, 36, 45 and 60 kW extreme cold weather kit for 2.4L engine 5616CH 48 kW extreme cold weather kit for 5.4L engine 6204CH 48 kW extreme cold weather kit for 4.2L engine (prior to February 2012) 5618CH 70, 100 and 130 kW generator extreme cold weather kit for 6.8L engine gear drive 5620CH 80 kW extreme cold weather kit for 4.6L engine 5619CH 150 kW generator extreme cold weather kit for 6.8L engine direct drive 5667CH Extreme cold weather kit (engine warmer) for air-cooled 8–10 kW, 410/530 cc engines (after April 2010) 5863CH Extreme cold weather kit (engine warmer) for air-cooled 14–20 kW, 760/992/999 cc engines (after April 2010) 5864CH 3 8 kW generator maintenance kit 410 cc engine. For #EGENX8 model only 6482CH 3 11 kW generator maintenance kit 530 cc engine. For #EGENX11 model only 6483CH 14 and 17 kW generator maintenance kit, 760/990 cc engine. For #EGENX14 & #EGENX17-17A models only 6484CH 20 kW generator maintenance kit, 999 cc engine. For #EGENX20A model only 6485CH 8 kW generator maintenance kit 410 cc engine. #EGEN8 vintage model only 5662CH 10 kW generator maintenance kit 530 cc engine. #EGEN10 vintage model only 5663CH 14 and 17 kW generator maintenance kit, 760/990 cc engine. #EGEN14 & EGEN17-17A vintage models only 5664CH 20 kW generator maintenance kit, 999 cc engine. #EGEN20A vintage model only 5665CH 22 and 27 kW generator maintenance kit, 2.4L engine 5656CH 25 and 30 kW generator maintenance kit, 1.5L engine 6176CH 25 and 30 kW generator maintenance kit, 1.6L engine (prior to February 2012) 5655CH 36 kW generator maintenance kit, 2.4L engine 5984CH 45 kW generator maintenance kit, 2.4L engine 6172CH 48 kW generator maintenance kit, 4.2L engine 5658CH 60 kW generator maintenance kit, 2.4L engine 6171CH 80 kW generator maintenance kit, 4.6L engine 5985CH 70, 100, 130 and 150 kW generator maintenance kit, 6.8L engine 5660CH Description General Accessories EGENMOBILE Cold Weather Kits Extreme Cold Weather Kits Maintenance Kits Wireless Remote Monitoring 3 3 Cold Weather Kits 3 3 Extreme Cold Weather Kits 3 3 3 3 Maintenance Kits 3 3 3 3 3 3 3 3 3 3 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T3-5 3.1 3 3 3 Residential Standby Backup Power Solutions Standby Generators Sizing Guidelines Dimensions When selecting the essential circuits that will be switched to “Backup Power,” it is important that the sum of the combined circuit loads does not exceed the wattage/amperage capacity of the generator. To help you with your selection of essential circuits, please add up the total wattage of all electrical devices to be connected at one time. This total should NOT be greater than the generator’s wattage capacity. Approximate Dimension in Inches (mm) Air-Cooled Standby Catalog Number Length Width Height Weight in Lbs (kg) EGENX8 48.00 (1219.2) 25.00 (635.0) 29.00 (736.6) 340 (154.4) Refer to Eaton Generator Sizing Guide Publication Number TD00405018E and consult with a trained professional. EGENX11 48.00 (1219.2) 25.00 (635.0) 29.00 (736.6) 387 (175.7) EGENX14 48.00 (1219.2) 25.00 (635.0) 29.00 (736.6) 439 (199.3) 3 Circuit Selection 123 EGENX17 48.00 (1219.2) 25.00 (635.0) 29.00 (736.6) 455 (206.6) 48.00 (1219.2) 25.00 (635.0) 29.00 (736.6) 421 (191.1) 3 Device Common Running Watts EGENX17A EGENX20A 48.00 (1219.2) 25.00 (635.0) 29.00 (736.6) 451 (204.8) 3 Air conditioner (12,000 btu) 1700 Air conditioner (24,000 btu) 3800 Liquid-Cooled Standby Air Conditioner (40,000 btu) 6000 Battery charger (20 amp) 500 Catalog Number Length Width Height Weight in Lbs (kg) 3 Circular saw (6-1/2-inch) 800–1000 EGEN22 62.00 (1574.8) 29.00 (736.6) 34.00 (863.6) 895 (406.3) 5750 EGEN25 63.00 (1600.2) 30.00 (762.0) 35.00 (889.0) 875 (397.3) 3 Clothes dryer (gas) 700 EGEN27 64.00 (1625.6) 31.00 (787.4) 36.00 (914.4) 891 (404.5) Clothes washer 1150 EGEN30 60.00 (1651.0) 32.00 (812.8) 37.00 (939.8) 935 (424.5) 3 Coffee maker 1750 EGEN36 77.00 (1955.8) 34.00 (863.6) 45.00 (1143.0) 1683 (764.1) Compressor (1 hp) 2000 EGEN45 78.00 (1981.2) 35.00 (889.0) 46.00 (1168.4) 1414 (642.0) 3 Compressor (1/2 hp) 1400 EGEN48 79.00 (2006.6) 36.00 (914.4) 47.00 (1193.8) 1703 (773.2) Compressor (3/4 hp) 1800 3 EGEN60 4 80.00 (2032.0) 37.00 (939.8) 48.00 (1219.2) 1650 (749.1) Curling iron 700 EGEN70 4 97.00 (2463.8) 37.00 (939.8) 48.00 (1219.2) 2185 (992.0) 3 Dehumidifier 650 EGEN80 4 Electric blanket 400 3 Electric range (per element) 1500 Electric skillet 1250 3 Freezer 700 Furnace fan (3/5 hp) 875 3 Garage door opener 500–750 Hair dryer 1200 3 Hand drill 250–1100 3 3 3 Clothes dryer (electric) Iron 1200 3 Jet pump 800 3 Light bulb 100 Microwave oven 700–1000 3 Milk cooler 1100 Oil burner on furnace 300 3 Oil fired space heater (140,000 btu) 400 Oil fired space heater (30,000 btu) 150 3 Oil fired space heater (85,000 btu) 225 Radio 50–200 3 Refrigerator 700 Slow cooker 200 3 Submersible pump (1 hp) 2000 Submersible pump (1/2 hp) 1500 3 Submersible pump (1-1/2 hp) 2800 3 Sump pump 800–1050 Table saw (10-inch) 1750–2000 3 Television 200–500 Toaster 1000–1650 115.00 (2921.0) 36.80 (934.7) 79.00 (2006.6) 2010 (912.5) 4 116.00 (2946.4) 36.80 (934.7) 80.00 (2032.0) 2705 (1228.1) EGEN130 4 117.00 (2971.8) 36.80 (934.7) 81.00 (2057.4) 2873 (1304.3) EGEN150 4 118.00 (2997.2) 36.80 (934.7) 82.00 (2082.8) 2666 (1210.4) EGEN100 Notes 1 The rated wattage of lights can be taken from light bulbs. The rated wattage of tools, appliances and motors can usually be found on a data plate or decal affixed to the device. 2 If the appliance, tool or motor does not give wattage, multiply 120 volts times the ampere rating to determine watts (volts x amps = watts) for single-phase only. 3 Some electric motors (induction types) require about three times more watts of power for starting than for running. This surge lasts for only a few seconds. Be sure you allow for this high starting wattage when selecting electrical devices that will be energized by the backup power system: Figure the watts required to start the largest motor. Add that to the total running watts of all other connected loads. 4 All weights provided for steel enclosures only. 3 V1-T3-6 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Residential Standby Backup Power Solutions Portable Generators 3.2 Contents EGENP8000EX Description Portable Generators Product Selection . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 3 V1-T3-8 V1-T3-10 3 3 3 3 3 3 3 3 3 Product Description Application Description Whereas permanently installed standby systems are designed for larger homes, small businesses or secondary residences, portable generators are primarily used for smaller homes, essential loads, construction sites, camping, tailgating and wherever portable temporary power is required. Portable generator systems are primarily used for smaller homes or for construction sites where temporary power is required. Permanently installed standby systems are designed for larger homes, small businesses or secondary residences, such as vacation homes and cabins, that require uninterrupted power for critical loads. 3 Standards and Certifications ● 3 UL Listed 3 3 3 3 3 3 As the name indicates and due to physical size and weight, portable generators can easily be transported from one location to another. 3 3 Designed for outdoor use only, common applications vary from homes to camping to construction sites, providing backup power everywhere electrical power is needed. 3 3 3 Catalog Number Selection 3 Portable Generators 3 EGEN P 8000 E X Eaton generator Type P = Portable Power Output 5500 = 5.5 kW 6500 = 6.5 kW 7000 = 7.5 kW 8000 = 8 kW 15000 = 15 kW 17500 = 17.5 kW Startup Method Blank = Manual/recoil only E = Electric and/or manual/recoil 3 3 Model Blank = General purpose CA = General purpose “CARB” compliant (CA only) X = XG Series Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 3 3 3 V1-T3-7 3.2 3 Portable Generators 3 Fuel Engine Tank Running Starting Displacement/ Startup Capacity Watts Watts Type Method (gal) 1 3 3 Portable Generators Product Selection 3 3 Residential Standby Backup Power Solutions Approx. Running Time at 1/2 load Battery Outlets (hrs) Included Configuration Warranty Residential/ Commercial Catalog (yrs) Number General Purpose (49-State) EGENP5500 5500 6875 389 cc/OHV Manual 7.2 10 No 1 x 30A L14-30R (twist lock), 2 x 20A 5-20R duplex 2/1 Ltd EGENP5500 EGENP6500 6500 8125 389 cc/OHV Manual 7.2 10 No 1 x 30A L14-30R (twist lock), 2 x 20A 5-20R duplex 2/1 Ltd EGENP6500 EGENP6500E 6500 8125 389 cc/OHV Manual/ 7.2 electric 10 Yes 1 x 30A L14-30R (twist lock), 2 x 120A 5-20R duplex 2/1 Ltd EGENP6500E EGENP7500E 7500 9375 420 cc/OHV Manual/ 8.0 electric 12 Yes 1 x 30A L14-30R (twist lock), 2 x 20A 5-20R duplex 2/1 Ltd EGENP7500E EGENP15000E 15000 22500 992 cc/OHVI Manual/ 16.0 electric 12 Yes 1 x 50A 14-50R, 1 x 30A L14-30R (twist lock), 2 x 30A L5-30R (twist lock), 1 x 20A 5-20R duplex, 1 x 20A GFCI 5-20R duplex 2/1 Ltd EGENP15000E EGENP17500E 17500 26250 992 cc/OHVI Manual/ 16.0 electric 10 Yes 1 x 50A 14-50R, 1 x 30A L14-30R (twist lock), 1 x 30A L5-30R (twist lock),1 x 20A 5-20R duplex, 1 x 20A 5-20R GFCI duplex 2/1 Ltd EGENP17500E 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 Notes 1 Requires gasoline as fuel to operate. 3 All 120/240V. Required gasoline as fuel. 3 3 3 3 3 V1-T3-8 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 3.2 Residential Standby Backup Power Solutions Portable Generators Portable Generators, continued Fuel Engine Tank Running Starting Displacement/ Startup Capacity Watts Watts Type Method (gal) 1 Approx. Running Time at 1/2 load Battery Outlets (hrs) Included Configuration 3 Warranty Residential/ Commercial Catalog (yrs) Number XG Series EGENP7000EX 7000 8750 407 cc/OHVI Manual/ 9 electric 10 Yes 1 x 30A L14-30R (twist lock), 2 x 20A GFCI 5-20R duplex 2/1 Ltd EGENP7000EX 3 3 3 3 3 EGENP8000EX 8000 10000 407 cc/OHVI Manual/ 10 electric 10 Yes 1 x 30A L14-30R (twist lock), 2 x 20A GFCI 5-20R duplex 2/1 Ltd EGENP8000EX 3 3 3 EGENP10000EX 10000 12500 530 cc/OHVI Manual/ 10 electric 10 Yes 1 x 50A 14-50R, 1 x 30A L14-30R (twist lock), 2/1 Ltd 1 x 30A L5-30R (twist Lock), 2 x 20A GFCI 5-20R duplex EGENP10000EX 3 3 3 3 CARB Compliant (Required in California Only) EGENP5500CA 5500 6875 389 cc/OHV Manual 7.2 10 No 1 x 30A L14-30R (twist lock), 2 x 20A GFCI 5-20R duplex 2/1 Ltd EGENP5500CA 3 3 3 3 EGENP6500CA 6500 8125 389 cc/OHV Manual 7.2 10 No 1 x 30A L14-30R (twist lock), 2 x 120A 5-20R duplex 2/1 Ltd EGENP6500CA 3 3 3 3 Notes 1 Requires gasoline as fuel to operate. 3 All 120/240V. Required gasoline as fuel. 3 3 3 3 3 3 3 3 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T3-9 3.2 3 Residential Standby Backup Power Solutions Portable Generators Dimensions Approximate Dimension in Inches (mm) 3 Portable Generators 3 Catalog Number Length Width Height Weight Lbs (kg) 3 EGENP5500 27.25 (692.2) 27.00 (685.8) 25.00 (635.0) 171.0 (77.6) 3 EGENP6500 27.25 (692.2) 27.00 (685.8) 25.00 (635.0) 175.0 (79.5) EGENP6500E 27.25 (692.2) 27.00 (685.8) 25.00 (635.0) 186.0 (84.4) 3 EGENP7500E 27.25 (692.2) 27.00 (685.8) 25.00 (635.0) 191.5 (86.9) EGENP15000E 48.50 (1231.9) 31.00 (787.4) 39.50 (1003.3) 363.0 (164.8) 3 EGENP17500E 48.50 (1231.9) 31.00 (787.4) 39.50 (1003.3) 390.0 (177.1) EGENP7000EX 31.00 (787.4) 25.50 (647.7) 28.00 (711.2) 245.0 (111.2) 3 EGENP8000EX 31.00 (787.4) 25.50 (647.7) 28.00 (711.2) 235.0 (106.7) 3 EGENP10000EX 30.00 (762.0) 29.50 (749.3) 31.00 (787.4) 300.0 (136.2) EGENP5500CA 27.25 (692.2) 27.00 (685.8) 25.00 (635.0) 170.9 (77.6) 3 EGENP6500CA 27.25 (692.2) 27.00 (685.8) 25.00 (635.0) 177.0 (80.3) 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 V1-T3-10 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 3.3 Residential Standby Backup Power Solutions Automatic Transfer Switches Contents Residential Automatic Transfer Switches Description Page Automatic Transfer Switches Standards and Certifications . . . . . . . . . . . . . . Catalog Number Selection . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . ATS Ready Loadcenter . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T3-12 V1-T3-12 V1-T3-13 V1-T3-14 V1-T3-15 3 3 3 3 3 3 3 3 3 3 Product Description 3 Application Description 3 50, 100, 150, 200 and 400A Fully Automatic Green Line of Automatic Transfer Switches 50, 100, 150, 200 and 400A Switches All Eaton automatic transfer switches (ATS) monitor utility and generator voltages and will automatically connect to the appropriate source of power. Eaton offers two types of automatic transfer switches to suit your personal backup power needs—the standard ATS EGSX series with load shedding capabilities and the Green ATS EGSU series that provides a truly active load management solution. With the rising cost of commodities and fuel in today’s economy, consumers are concerned with maximizing the value of their purchases. 100, 200 and 400A switches are capable of “whole house” power transfer in residential/ small business applications. Electrical loads are now intelligently managed with Eaton’s Green Line of automatic transfer switches. The active load management inside each Green ATS allows the consumer to use 100% of the power rated output of the generator and/or use a smaller generator, reducing upfront installation costs and saving on ongoing fuel consumption costs. As a part of Eaton’s commitment to quality, every Green ATS, at no extra cost, will ship with a CHSPT2ULTRA whole surge protector, which will help prevent potential damage to valued electronics caused by power surges in the utility line. 3 3 3 50A—Indoor Installation—Selected Load Pre-Wired 50A Indoor Transfer Switch Meter Standby Generator 100/200A Service Panel 3 3 Fuel Supply (NG or LP) 3 3 Air Conditioner 100/200A—Outdoor Installation—Whole House Pre-Wired Service Disconnect 3 3 Meter 100/200A Outdoor Transfer Switch Sound Attenuated Enclosure 3 3 Sound Attenuated Enclosure Standby Generator 3 Low Voltage Disconnect 3 3 3 3 Fuel Supply (NG or LP) Air Conditioner Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 100/200A Service Panel V1-T3-11 3 3 3.3 3 3 Residential Standby Backup Power Solutions Automatic Transfer Switches Standards and Certifications ● UL 1008 listed 3 3 3 Catalog Number Selection 3 Standard Automatic Transfer Switches—EGSX Series 3 E GSX 200 3 Manufacturer Eaton 3 Type Generator transfer switch EGSX Series 3 3 Ampere Rating 50 = 50A 100 = 100A 150 = 150A 200 = 200A 400 = 400A NSEA Loadcenter (CH Type, Integral) Blank = None L12 = 12 circuits N1 L12R = 12 circuits N3R L24R = 24 circuits N3R Service Entrance Rated NSEA = Service entrance (normal source only) A = Non-service entrance 3 3 Green Automatic Transfer Switches—EGSU Series E GSU 200 3 3 Manufacturer Eaton 3 3 Type Generator universal transfer switch EGSU “Green” Series Ampere Rating 100 = 100A 150 = 150A 200 = 200A 400 = 400A NSE ACA Loadcenter (CH Type, Integral) Blank = None L24 = 24 circuits Service Entrance Rated NSE = Service entrance (normal source only) Blank = Non-service entrance 3 3 3 3 3 3 3 3 3 3 3 3 3 V1-T3-12 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Load Management ACA = Active load management Residential Standby Backup Power Solutions Automatic Transfer Switches 3.3 Product Selection EGSX50L12R EGSU200NSEACA CHSPT2ULTRA 5 3 3 Standard Automatic Transfer Switches 1 3 Service Ampere Entrance Rating Voltage Rated No. of Load Contactor Shed Wire Size Contacts Range(s) Recommended No. of Withstand No. of Frequency Enclosure Generator Catalog Cables Current (rms) Circuits Type Sizes (kW) 3 Number per Phase at 240 Vac Included 2 (Hz) 50 120/240 No 2 #14–#6 1 5000 12 50/60 NEMA 1 (indoor) 8, 11 EGSX50L12 50 120/240 No 2 #14–#6 1 5000 12 50/60 NEMA 3R (outdoor) 8, 11 EGSX50L12R 100 120/240 No 2 #14–#2/0 1 10,000 — 50/60 NEMA 3R (outdoor) 8, 11, 14 EGSX100A 100 120/240 Yes 2 #14–#2/0 1 10,000 — 50/60 NEMA 3R (outdoor) 8, 11, 14 EGSX100NSEA 3 100 120/240 No 2 #14–#2/0 1 25,000 24 50/60 NEMA 3R (outdoor) 8, 11, 14 EGSX100L24RA 3 150 120/240 Yes 2 #4–300 kcmil 1 25,000 — 50/60 NEMA 3R (outdoor) 14, 17, 20 EGSX150NSEA 3 200 120/240 No 2 #4–300 kcmil 1 25,000 — 50/60 NEMA 3R (outdoor) 14, 17, 20 EGSX200A 3 200 120/240 Yes 2 #4–300 kcmil 1 25,000 — 50/60 NEMA 3R (outdoor) 14, 17, 20 EGSX200NSEA 3 400 120/240 Yes 2 750 kcmil–2 1/2 300 kcmil–1/0 35,000 — 50/60 NEMA 3R (outdoor) >20 EGSX400NSEA 3 Contactor Wire Size Range(s) No. of Cables per Phase Withstand No. of Current (rms) Circuits at 240 Vac Included 2 Frequency (Hz) Enclosure Type 100 120/240 No #14–#2/0 1 10,000 — 50/60 100 120/240 Yes #14–#2/0 1 10,000 — 100 120/240 No #14–#2/0 1 10,000 150 120/240 Yes #4–300 kcmil 1 200 120/240 No #4–300 kcmil 200 120/240 Yes 400 120/240 Yes 3 3 3 3 Green Automatic Transfer Switches 4—Featuring Active Load Management Technology Service Ampere Entrance Rating Voltage Rated 3 Recommended Generator Sizes (kW) 3 Catalog Number NEMA 3R (outdoor) 8, 11, 14 EGSU100ACA 3 50/60 NEMA 3R (outdoor) 8, 11, 14 EGSU100NSEACA 3 24 50/60 NEMA 3R (outdoor) 8, 11, 14 EGSU100L24RACA 3 25,000 — 50/60 NEMA 3R (outdoor) 14, 17, 20 EGSU150NSEACA 3 1 25,000 — 50/60 NEMA 3R (outdoor) 14, 17, 20 EGSU200ACA 3 #4–300 kcmil 1 25,000 — 50/60 NEMA 3R (outdoor) 14, 17, 20 EGSU200NSEACA 3 750 kcmil–2 300 kcmil–1/0 1/2 35,000 — 50/60 NEMA 3R (outdoor) >20 EGSU400NSEACA 3 3 3 Notes 1 Standard ATS “EGSX” Series compatible with Eaton generators only. 2 Uses CH type circuit breakers. 3 For reference only. Generator size must be determined with proper/actual load calculations. 4 UNIVERSAL ATS: compatible with any single-phase, 120/240V generator brand. 5 Whole house surge Cat. No. CHSPT2ULTRA included in every Green ATS “EGSU” Series. 3 3 3 3 3 3 3 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T3-13 3.3 3 3 3 3 3 3 3 3 Automatic Transfer Switches ATS Ready Loadcenter From the far-reaching power failures brought on by hurricanes and snow/ice storms, to the increasing power outage concerns and an aging electrical infrastructure, backup power is more important than ever. Eaton’s ATS Ready loadcenter addresses future backup power needs by enabling a fast, efficient installation of an automatic transfer switch kit to convert from utility power to generator power. The ATS 3 3 Residential Standby Backup Power Solutions Ready loadcenter gives homebuilders and electrical contractors the flexibility to install a generator ready system or to install a loadcenter and easily add an ATS in the future. Backup power had never been that versatile before. ATS Ready Loadcenter Features ● CH Premium Type 200A single-phase MCB 36-circuit loadcenter ● 50A ATS “EGSX” type kit for factory or field installation (compatible with Eaton generators only) ● 22 circuits for nonessential loads and 14 circuits for essential backup power loads ● Versatile, space-saving design ATS Ready Loadcenter Description Catalog Number CH36B200EGP ATS Ready loadcenter Kit CHEGSX50KIT must be ordered separately Loadcenter only. Includes provision for ATS kit CH36B200EGP CHEGSX50KIT ATS “EGSX” kit for ATS Ready loadcenter Field-installable automatic transfer switch kit ATS Ready loadcenter CH36B200EGP must be ordered separately Intuitive, easy installation Compatible with Eaton generators only CHEGSX50KIT CH36B200EGPK ATS Ready LC with factory-installed ATS kit Factory assembled Compatible with Eaton generator only. Generator needed to complete backup power system Recommended Eaton generators models: 8/7 kW–Catalog #EGENX8 11/10 kW–Catalog #EGENX11 CH36B200EGPK 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 V1-T3-14 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com ● ● ● ● ● For use with 8 or 11 kW air-cooled generators CH cover included Lifetime warranty on CH loadcenter and breakers NEMA 1 design UL Listed Residential Standby Backup Power Solutions Automatic Transfer Switches 3.3 Dimensions Approximate Dimension in Inches (mm) 3 Automatic Transfer Switches 3 Catalog Number Width Height Depth Weight Lbs (kg) 3 EGSX50L12 14.25 (362.0) 21.00 (533.4) 4.00 (101.6) 25 (11.33) EGSX50L12R 14.25 (362.0) 21.00 (533.4) 6.00 (152.4) 29 (13.15) 3 EGSX100A 14.46 (367.3) 16.87 (428.5) 5.32 (135.1) 25 (11.33) EGSX100NSEA 14.46 (367.3) 16.87 (428.5) 5.32 (135.1) 28 (12.70) EGSX100L24RA 14.46 (367.3) 29.33 (744.0) 5.32 (135.1) 38 (17.24) EGSX200A 14.46 (367.3) 25.08 (637.0) 5.25 (133.4) 35 (15.87) EGSX150NSEA 14.46 (367.3) 29.20 (741.7) 5.32 (135.1) 45 (20.41) EGSX200NSEA 14.46 (367.3) 29.20 (741.7) 5.32 (135.1) 45 (20.41) EGSU100L24RACA 14.46 (367.3) 29.33 (745.0) 5.32 (135.1) 38 (17.24) EGSU100ACA 14.46 (367.3) 16.87 (428.5) 5.32 (135.1) 25 (11.33) EGSU100NSEACA 14.46 (367.3) 16.87 (428.5) 5.32 (135.1) 28 (12.70) EGSU150NSEACA 14.46 (367.3) 29.20 (741.7) 5.32 (135.1) 45 (20.41) EGSU200ACA 14.46 (367.3) 25.08 (637.0) 5.25 (133.4) 35 (15.88) EGSU200NSEACA 14.46 (367.3) 29.20 (741.7) 5.32 (135.1) 45 (20.41) EGSU400NSEACA 23.14 (587.8) 35.55 (903.0) 10.00 (254.0) 120 (54.43) CH36B200EGPK 47.50 (1206.5) 3.88 (98.6) 40 (18.14) 14.31 (363.5) 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T3-15 3.4 3 Residential Standby Backup Power Solutions Manual Transfer Switches All Panels are Manufactured in the USA and Meet UL 1008 Contents Description 3 Page Manual Transfer Switches Standards and Certifications . . . . . . . . . . . . . . Reference Information . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3 3 V1-T3-17 V1-T3-17 V1-T3-18 V1-T3-19 V1-T3-19 Learn Online 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 Product Description Application Description Features, Benefits and Functions A manual transfer switch is a device that is mounted next to the loadcenter (distribution panel) in the home or small business. The manual transfer switch is used in conjunction with a portable backup power generator and serves the purpose of turning selected circuits on and off during a power outage. The transfer switch panel allows the owner to start up a generator to restore power to critical circuits when utility power is not available. Manual transfer switches are most often used in residential, agricultural and light commercial applications. Comfort and safety are key concerns of many homeowners who are dependent on an uninterrupted supply of electricity. Eaton offers two manual transfer switch backup power solutions: The owner designates which circuits are critical, such as the refrigerator and certain lights. Sometimes called emergency power panels or emergency generator panels, manual transfer switch panels provide the homeowner or small business owner with a safe and easy way to continue using electrical appliances when the utility power is unavailable temporarily. ● ● Manual Transfer Switches ● ● The increase in our dependence on power is due in part to the popularity of home offices and in-home health care. Various heavily populated regions of the United States experience periodic power outages due to extreme weather conditions, such as ice and snowstorms, heat waves, tornadoes or hurricanes. These regions that include the Pacific Northwest, Atlantic Coast and the Gulf Coast are the strongest markets for portable generators and manual transfer switches. Manual transfer switches Generator panels ● ● ● ● ● Panel and components sold separately Hardwired generator connection Ideal for new construction/ larger loads Sturdy copper bus construction Uses CH and CHNT circuit breaker types (sold separately) Mechanically interlocked main disconnects to prevent paralleling of normal and emergency power source Indoor and outdoor designs available 3 3 3 3 3 V1-T3-16 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Manual Transfer Switch Indoor Design Manual Transfer Switch Indoor/Outdoor Design 3.4 Residential Standby Backup Power Solutions Manual Transfer Switches Standards and Certifications Generator Panels ● ● ● ● ● ● Mechanically interlocked main disconnects prevent paralleling of normal and emergency power source Panel and components sold separately Integral plug-in generator connection (power inlet box) All circuit breakers are included—switching duty rated Includes dual wattmeters for load balancing Indoor and outdoor designs available Generator Panel Indoor Design ● ● 3 UL 67 listed UL 1008 listed 3 3 3 Reference Information 3 3 Cross-Reference Ampere Rating Catalog Number Watts Number of Circuits Eaton Gen/Tran 1 EmerGen 1 Square D Generac 1 5000 4–8 30 CH48GEN3060R — — QO48M30DSGP — 15,000 8–16 60 CH816GEN6060 — — QO48M60DSGP — 5000 6 20 CH6EGEN2060 20216 6-5000 — — 5000 6 20 CH6EGEN2060R R20216 6-5000 + RTE657 — — 5000 6 20 CH6EGEN2060SU — — — — 5000 6 20 CH6EGEN2060RSU — — — — 7500 10 30 CH10EGEN3060 302110-20 10-7500 — — 7500 10 30 CH10EGEN3060R R30211-20 10-7500 + RTE1075 — — 7500 10 30 CH10EGEN3060SUR — — — — 7500 10 30 CH10EGEN3060RSU — — — — 7500 10 30 CH10GEN5030SN — — — — 7500 10 30 CH10GEN5030RSN — — — — 12,000 10 50 CH10GEN5050SN — — — — 12,000 10 50 CH10GEN5050RSN — — — — 3 3 3 3 3 3 3 3 3 3 Notes 1 Gen/Trans device is not supplied with a power cord. 2 Generac device is 7200 maximum watts on six-circuit device and 12,000 maximum watts on 10-circuit device. 3 3 3 3 3 3 Generator Panel Outdoor Design 3 3 3 3 3 3 3 3 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T3-17 3.4 3 Residential Standby Backup Power Solutions Manual Transfer Switches Product Selection 3 Manual Transfer Switches and Generator Panels Selection 3 Enclosure Type 3 Watts Number of Circuits Ampere Rating Main/ Emergency Ampere Rating Feeder Breakers Included Accessories Catalog Number Standard Manual Transfer Switch 3 NEMA 3R 5000 4–8 30 Provision Provision None CH48GEN3060R NEMA 1 10,000 8–16 60 Provision Provision None CH816GEN6060 3 Generator Panel 3 NEMA 1 5000 6 20 60/20 5–1P151–1P20 None CH6EGEN2060 NEMA 3R 5000 6 20 60/20 5–1P151–1P20 None CH6EGEN2060R 3 NEMA 1 5000 6 20 60/20 5–1P151–1P20 Two-pole surge protector CH6EGEN2060SUR NEMA 3R 5000 6 20 60/20 5–1P151–1P20 Two-pole surge protector CH6EGEN2060RSU 3 NEMA 1 7500 10 30 60/30 6–1P152–1P2012P30 None CH10EGEN3060 NEMA 3R 7500 10 30 60/30 6–1P152–1P2012P30 None CH10EGEN3060R 3 NEMA 1 7500 10 30 60/30 7–1P152–1P2012P30 Two-pole surge protector CH10EGEN3060SUR 3 NEMA 3R 7500 10 30 60/30 7–1P152–1P2012P30 Two-pole surge protector CH10EGEN3060RSU 3 NEMA 1 7500 10 30 50/30 6–1P15, 2–1P20, 1–2P30 None CH10GEN5030SN NEMA 3R 7500 10 30 50/30 6–1P15, 2–1P20, 1–2P30 None CH10GEN5030RSN NEMA 1 12,000 10 50 50/50 6–1P15, 2–1P20, 1–2P30 None CH10GEN5050SN NEMA 3R 12,000 10 50 50/50 6–1P15, 2–1P20, 1–2P30 None CH10GEN5050RSN Switched Neutral Manual Transfer Switch 3 3 3 Power Inlet Boxes 3 Description Flush flange kit (for use with generator panel only) 3 3 3 3 3 3 3 3 3 Ampere Rating Voltage Catalog Number — 120/240V CHEGENFKIT Power inlet box 20 120/240V EGSPIB20 Power inlet box 30 120/240V EGSPIB30 Power inlet box 50 120/240V EGSPIB50 Warranty Manual Transfer Switch ● 15-year loadcenter warranty ● Lifetime branch breaker warranty Generator Panel ● 15-year loadcenter warranty ● Lifetime branch breaker warranty 3 3 3 3 3 V1-T3-18 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 3.4 Residential Standby Backup Power Solutions Manual Transfer Switches Technical Data and Specifications ● ● ● ● 3 10,000 AIC rating Switching devices must be circuit breakers Manual transfer switch must be supplied with neutral and ground Power inlet box must be connected to a circuit breaker for generator protection 3 3 3 3 Installation Diagrams Manual Transfer Switches—Indoor Installation Diagram Eaton Manual Transfer Switch 3 Generator Panels—Indoor Installation Diagram Utility Power Feed Generator Panel Utility Power Feed Power Inlet Box* Existing Main Power Panel Power Cord* Power Inlet Box* Existing Main Power Panel Power Cord* (Loadcenter) (Loadcenter) Two-Pole, 60A Breaker* to Feed the Emergency Generator Panel From Your Existing Main Power Panel (Loadcenter) Two-Pole, 60A Breaker* to Feed the Emergency Power Panel From Your Existing Main Power Panel Hardwired Generator* (Loadcenter) Electrical Connection* * Not Included Manual Transfer Switches—Outdoor Installation Diagram Eaton Manual Transfer Switch Utility Power Feed Power Inlet Box* Existing Main Power Panel Power Cord* Generator* Electrical Wiring or Power Cord* Prewired Connector for Faster Installation - Included Hardwired Electrical Connection* 3 3 3 3 3 3 3 Prewired Connector for Faster Installation - 3 Included Utility Power Feed 3 3 (Loadcenter) Generator* 3 3 Generator Panel (Loadcenter) Two-Pole, 60A Breaker* to Feed the Emergency Power Panel From Your Existing Main Power Panel 3 3 * Not Included Generator Panels—Outdoor Installation Diagram Two-Pole, 60A Breaker* to Feed the Emergency Generator Panel From Your Existing Main Power Panel 3 3 Power Cord* * Not Included Generator* *Not Included 3 3 Dimensions 3 Approximate Dimensions in Inches (mm) Manual Transfer Switch Enclosure Type Height Width NEMA 1 16.75 (425.5) NEMA 3R 13.00 (330.2) 3 Generator Panel Depth Weight Lbs (kg) Enclosure Type Height Width Depth Six-Circuit 10-Circuit 14.31 (363.5) 3.88 (98.5) 25 (11) NEMA 1 13.23 (336.0) 11.41 (289.8) 4.10 (104.1) 24 (11) 26 (12) 11.00 (279.4) 3.56 (90.4) 14 (6) NEMA 3R 17.12 (434.8) 9.45 (240.0) 7.16 (181.9) 29 (13) 31 (14) Weight Lbs (kg) 3 3 3 3 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T3-19 Structured Wiring Intercom System 4.1 StructuredWiringSolutions™ Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Application Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-2 V1-T4-2 V1-T4-4 V1-T4-21 4 4 4 4 Learn Online 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com V1-T4-1 4.1 4 Structured Wiring StructuredWiringSolutions Contents Intercom System Description 4 StructuredWiringSolutions Product Selection. . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 Product Description Application Description Structured wiring is a simple, affordable way to wire a home for state-ofthe-art communications, entertainment and security now and for many years to come. ● The basic concept is that all telephone, television, satellite, coaxial, audio and data communications cables are wired in a star topology (home run) to each room in the home and terminate at a central distribution panel. This distribution panel allows flexibility for future modifications and/or additions to keep pace with a homeowner’s lifestyle and needs. ● ● ● ● ● Telephone High-speed Internet Computer networks Web-safe Internet router Whole-house sound Satellite/cable TV Wall Outlets and Basic Package Structured wiring can also be used as a central hub to interconnect a security system, home automation, HVAC and load control, providing a complete system to increase the security, comfort and convenience for a homeowner. 4 4 4 4 4 V1-T4-2 Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com Page V1-T4-4 V1-T4-21 Structured Wiring StructuredWiringSolutions 4.1 A Home with StructuredWiringSolutions Gives You Ready Control of the Latest in Computing, Audio, Video and Communications. With the Right Components, Your Dream Home is Ready for Today’s World and Tomorrow’s Advancements. Your Value is Ensured...and so is Your Peace of Mind 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com V1-T4-3 4.1 4 4 StructuredWiringSolutions Product Selection 4 4 Structured Wiring Packaged Products Product Description UPC Code Catalog Number ESWB100 Perfect for apartments, condos or even entry level homes. This distribution panel distributes four incoming telephone lines to six locations, punchdown, and one incoming coax signal to four locations, passive. Installation is easy and a stylish three-gang wall plate cover provides a professional looking finish. 782116895359 ESWB100 ESWB100P Same as ESWB100, except punchdown for telephone is doubled for 11 locations and there is no coax distribution. Perfect for commercial and resi applications for phone only, or for six phone locations and/or six computer locations. 782116895366 ESWB100P 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 V1-T4-4 Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com Structured Wiring StructuredWiringSolutions 4.1 Video Modules ESWV10400 Product Description UPC Code Catalog Number 1 x 4 coax module. 1 in, 4 out coax module with four pass-through connectors. 6-inch form factor. 1.0 lb. 782116895502 ESWV10400 4 4 4 4 ESWV10800 1 x 8 coax module. 1 in, 8 out coax module with two pass-through connectors. 6-inch form factor. 1.3 lbs. 782116895496 ESWV10800 4 4 4 ESWV10800A 1 x 8 amplified coax module. 1 in, 8 out coax module with 12 dB bi-directional amplifier and two pass-through connectors. 6" form factor. 2.4 lbs. 782116895519 ESWV10800A 4 4 4 ESWV50800A 5 x 8 coax module. 5 in, 8 out coax module with 20 dB bi-directional amplifier, surge protection, and four pass-through connectors, and four inputs for modulated signals. 12-inch form factor. 3 lbs. 782116895526 ESWV50800A 4 4 4 ESWV51200A 5 x 12 coax module. 5 in, 12 out coax module with 20 dB bi-directional amplifier, surge protection, and four pass-through connectors, and four inputs for modulated signals. 12-inch form factor. 3.5 lbs. 782116895533 ESWV51200A 4 4 ESWV51600A 5 x 16 coax module. 5 in, 16 out coax module with 20 dB bi-directional amplifier, surge protection, with one direct and four inputs for modulated signals. 12-inch form factor. 3.6 lbs. 782116895557 ESWV51600A 4 4 4 110 Volt video amplifier power supply. Power supply for all amplified video modules. 782116009671 4 ESWV110 4 4 4 4 4 4 4 4 4 4 4 Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com V1-T4-5 4.1 StructuredWiringSolutions Telephone Modules 4 4 Structured Wiring Product Description UPC Code Catalog Number ESWT41200P 12-port, four-line punchdown telephone module. The 12/4 punchdown telephone module has 12 110 punchdown blocks that distribute four incoming lines to 12 locations. 6-inch form factor. 1 lb. 782116895434 ESWT41200P ESWT40800 Eight-port, four-line telephone module. Eight RJ-45 ports support four incoming phone lines. One RJ31X port for security. 6-inch form factor. 1.0 lb. 782116895441 ESWT40800 ESWT41600 16-port, four-line telephone module. 16 RJ-45 ports support four incoming phone lines. One RJ31X port for security. 6-inch form factor. 1.25 lbs. 782116895458 ESWT41600 ESWTB48800 4 x 8 telephone breakout module. Distributes four incoming telephone lines to eight locations, RJ-45 style, eight breakout ports, four-line pass-through. Breakout configurations: 1-2, 2-1, 3-4, 4-3. 782116894499 ESWTB48800 ESWTB801 Eight location non-bridged phone module. Eight RJ-45 jacks connected directly to eight 110 punchdown connectors, (one-to-one) can be bridged together, great for Ethernet switches and routers. 786685255859 ESWTB801 ESWTB00 Telephone line breakout module. This module can be hung from an RJ-45 wall plate to break out and put lines 1–4 on individual center pairs so that all four lines in the RJ-45 jack are connectable to a standard RJ11 wired device. 782116895465 ESWTB00 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 V1-T4-6 Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com Structured Wiring StructuredWiringSolutions 4.1 Combination Modules ESWD40800 Product Description UPC Code Catalog Number Combo 4 x 8 coax/phone distribution module (with RJ-45 patch connectors). Distributes one incoming coax TV line to four locations (plus two pass-through) and four telephone lines to eight locations. Includes an RJ31X connection. 6-inch form factor. 1.1 lbs. 782116895472 ESWD40800 4 4 4 4 ESWD40800P Combo 4 x 8 coax/phone distribution module (with 110 punchdown connectors). Distributes one incoming coax TV line to four locations (plus two pass-through) and four telephone lines to eight locations. 6-inch form factor. 1.2 lbs. 782116895489 ESWD40800P 4 4 4 ESWD80800 Combo 8 x 8 passive coax/phone distribution module (with RJ-45 patch connectors). Distributes one incoming coax TV line to eight locations (plus two pass-through) and four telephone lines to eight locations. Includes an RJ31X connection. 6-inch form factor. 1.2 lbs. 782116895380 Combo 8 x 8 active coax/phone distribution module (with RJ-45 patch connectors). Distributes one incoming coax TV line to eight locations with built-in amplification (plus two pass-throughs) and four telephone lines to eight locations. Includes an RJ31X connection. 6-inch form factor. 1.2 lbs. 782116895397 Combo 8 x 8 passive coax/phone distribution module (with 110 punchdown connectors). Distributes one incoming coax TV line to eight locations (plus two pass-through) and four telephone lines to eight locations. 6-inch form factor. 1.2 lbs. 782116895373 ESWD80800 4 4 4 ESWD80800A ESWD80800P ESWD80800A 4 4 ESWD80800P 4 4 4 ESWD80800AP Combo 8 x 8 active coax/phone distribution module (with 110 punchdown connectors). Distributes one incoming coax TV line to eight locations with built-in amplification (plus two pass-throughs) and four telephone lines to eight locations. Includes an RJ31X connection. 6-inch form factor. 782116895403 ESWD80800AP 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com V1-T4-7 4.1 StructuredWiringSolutions Modules 4 4 Structured Wiring Product Description UPC Code Catalog Number ESWF001 Blank filler module. Use this blank filler module to hide cables in the panel. 782116031467 ESWF001 ESWP100 Blank patch module. Use this blank patch module to custom design a zone. The blank patch module accepts any configuration of CAT5e, RG6 coax or fiber optic inserts. Labeling areas allow you to identify the connections and what rooms they represent. 6-inch form factor. 782116895427 ESWP100 ESWMP300 Three-zone patch module. 12 connection ports (two CAT5 and two coax per zone). 6-inch form factor. 0.8 lbs. Allows for many room locations (wall plates) to be terminated cleanly and professionally without having to add expensive service modules. Active wall plates can be patch corded to data, voice or video modules as needed without complication or added expense. Outlet locations can be permanently labeled for easy consumer plug n’ play, and changing applications and life styles. 782116895410 ESWMP300 ESWM300 Triple channel modulator module. Used for creating in-home television channels for viewing from any TV in the home. Signals from three different audio/video sources such as TV, VCR, DVD, DBS, satellite TV and security cameras may be identified and displayed by any television. 6-inch form factor. 2.1 lbs. 782116895557 ESWM300 ESWMOD1 One-channel standalone modulator. Distributes one video signal (camera, DVD, SATV, CATV) to any television in the house. 782116895564 ESWMOD1 ESWMOD1 Three-channel standalone modulator. Distributes three video signals (camera, DVD, SATV, CATV) to any television in the house. 782116895571 ESWMOD1 ESWN100 Four-port 10/100 wireless firewall router. Distributes DSL/Broadband service up to four computer locations. Also provides wireless connectivity. 782116895342 ESWN100 V1-T4-8 Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 Structured Wiring StructuredWiringSolutions 4.1 Modules, continued ESWN400 Product Description UPC Code Catalog Number DSL or cable router with four-port 10/100M fast ethernet switch. Built-in NAT Firewall. 6-inch form factor. 782116895588 ESWN400 4 4 4 4 ESWN800 Eight-port 10/100M DSL or cable router. Built-in NAT and parental controls. 786685245768 4 ESWN800 4 ESWMS100 Product shelf 14 x 4 inches. Can be mounted anywhere in the panel. Allows for third-party products to be mounted in the panel. (Modems, power strip, etc.) 782116894437 ESWMS100 ESWMS200 Service shelf 14 x 8 inches. Can be mounted anywhere in the panel. Designed as a work shelf for the installer. 782116977192 ESWMS200 4 4 4 4 ESWMS300 4 12-inch blank mounting shelf. Stand-off hole placements for Ademco, First Alert, Caddx, DSC, and Electronics Line security panels. 782116049318 ESWMS300 4 4 ESWMSC300 12-inch blank mounting shelf cover. Designed to fit over the ESWMS300. 782116049325 ESWMSC300 4 4 4 ESWV100 Camera with IR emitters. 1/4-inch color camera with IR emitters for night-time viewing. Includes mounting bracket. Does not include power supply. 782116977178 ESWV100 4 4 ESWV200 4 Dome camera. 3.6 mm color dome camera. Can be flush or surface mounted. Does not include the power supply. 782116977185 ESWV200 4 4 ESWVQ4 Four-position video processor. Allows viewing of four cameras on one channel. Includes remote for easy access. 786685245775 4 ESWVQ4 4 4 4 20-pack of molly rivets and plungers. Use for connecting individual modules to the install can. 782116103126 4 ESWVRIV 4 4 4 4 Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com V1-T4-9 4.1 StructuredWiringSolutions Audio System Components 4 4 Structured Wiring Product Description UPC Code Catalog Number 75-watt volume control. For analog audio systems. White 782116895328 ESWA75W Almond 782116895335 ESWA75A ESWA6500SC 6.5-inch standard round ceiling speaker. 3/4-inch Mylar swivel tweeter, 80 watts. 782116894413 ESWA6500SC ESWA6550SC 6.5-inch high-end round ceiling speaker (set of two). In-ceiling, 6.5-inch poly woofer, 1-inch swivel tweeter. Surround sound capable. Suitable for all audio systems. 782116895304 ESWA6550SC ESWA0800SC 8-inch round ceiling speaker. 1-inch cloth swivel tweeter, 120 watts. 782116894420 ESWA0800SC ESWA6500SW 6.5-inch in-wall speakers (set of two). In-wall, 6.5-inch poly woofer, 0.75-inch tweeter. Surround sound capable. Suitable for all audio systems. 782116895311 ESWA6500SW ESWA5500OW 5.5-inch outdoor speakers (set of two). Outdoor, 5.5-inch poly woofer, 0.75-inch tweeter. Surround sound capable. Suitable for all audio systems. White 782113965918 ESWA5500OW Black 782113965925 ESWA5500OB ESWA65DVC 6.5-inch round dual voice coil speaker. Dual 1/2-inch Mylar tweeters, 80 watts. Suitable for small room installations. 786685271491 ESWA65DVC ESWA65ABD 6.5-inch round A-BUS direct ceiling speaker. Built-in A-BUS amplification. Shipped with multi-function multi-source remote with cradle. 786685285092 ESWA65ABD ESWA55OABDW 5.5-inch A-BUS direct outdoor speakers. Weather resistant, UV protected. Outdoor speakers with built-in Class D A-BUS amplifier. 786685366401 ESWA55OABDW ESWA6R 6.5-inch rough-in ring. Designed to fit models ESWA6500SC, ESWA6550SC, ESWA65DVC and ESWA65DVC. 786685366425 ESWA6R ESWA8R 8-inch rough-in ring. Designed to fit model ESWA800SC. 786685366418 ESWA8R ESWA75W 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 V1-T4-10 Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com Structured Wiring StructuredWiringSolutions 4.1 A-BUS Products Product Description ESWAM600C UPC Code A-BUS audio distribution module (6-inch form factor). The Zone 6 audio distribution module distributes CAT5 audio to six 782116153084 locations. Can be cascaded to one or two additional modules for 12 or 18 locations. Catalog Number ESWAM600C 4 4 4 ESWAM800 Eight-location audio distribution module. Distributes one signal to eight stereo locations via traditional speaker wire up to 16 gauge. 786685015194 ESWAM800 4 4 4 ESWAMK4801C 4 Source, 8 zone A-BUS audio kit. Kit includes power supply, (4) source input plates (ESWA7500CW) and (1) ESWA300 remote. 786685401331 ESWAMK4801C 4 4 4 ESWAM4801C 4 Source, 8 zone A-BUS audio module. Audio module only with power supply. 786685401317 ESWAM4801C 4 4 4 4 ESWA200CW ESWA300CW ESWA400CW A-BUS volume control. The volume control is the down line amplifier that converts the distributed audio signal back to an analog signal that is then distributed over speaker wire to in-wall/ceiling speakers. White 786685017297 ESWA200CW Almond 786685017280 ESWA200CA 4 4 4 A-BUS volume control with “IR” input option. The IR allows the entertainment center's wireless remote to be used in rooms that have this feature. Decora faceplate not included. White 782116153121 ESWA300CW Almond 782116153138 ESWA300CA 4 4 4 A-BUS two-button volume control with “IR” input option. Decora faceplate not included. White. 782116978038 ESWA400CW Almond 782116978045 ESWA400CA 4 4 4 ESWA4500CW 4 A-BUS four-position backlit multi-source volume control with “IR” input option. Specifically designed for use with the ESWAM4800 multi-source module. Decora faceplate not included. White. 782116894444 ESWA4500CW Almond 782116894451 ESWA4500CA 4 4 4 ESWA701CW A-BUS local input plate. Overrides the whole house music and allows a local source such as MP3 player and TVs to play in the zone or room. White 786685359197 ESWA701CW Almond 786685359205 ESWA701CA 4 4 4 4 Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com V1-T4-11 4.1 StructuredWiringSolutions A-BUS Products, continued 4 Product Description UPC Code Catalog Number Source input plate for multi-source A-BUS audio A-BUS. Provides one input and pass-through for audio equipment. Input for one IR emitter and one relay output. 786685401324 ESWA7500CW ESWAP A-BUS modules power supply 782116978021 ESWAP ESWA100CR A-BUS four-button remote control. For use with all A-BUS volume controls with IR inputs. Controls volume and source inputs. 782116894475 ESWA100CR ESWA300CR A-BUS IR remote control. For use with all A-BUS volume controls. Single and multi-source operation. Shipped with mounting cradle. 786685362175 ESWA300CR ESWA500C A-BUS component interface unit. The ESWA500C is used when the customer’s amplifier does not have an A-BUS CAT5e output built in. RCA connectors are run from the amplifier to the ESWA500C, and then a CAT5e homerun is made to the ESWAM600C in the main distribution panel. 782116153145 ESWA500C ESWEM100 A-BUS single lead “IR” emitter. 782116940189 ESWEM100 ESWEM200 A-BUS dual lead “IR” emitter. 782116940196 ESWEM200 ESWABI100 A-BUS two-door intercom module. This module is the core of the incom system. Includes two-door station outputs and eight room locations. 782116940202 ESWABI100 ESWABI200 A-BUS mini master room keypad. White 782116940219 ESWABI200 Almond 786685138572 ESWABI200A A-BUS control center (master keypad). White 782116940226 ESWABI300 Almond 786685138589 ESWABI300A 4 4 Structured Wiring 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 ESWABI300 4 4 4 4 V1-T4-12 Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com Structured Wiring StructuredWiringSolutions 4.1 A-BUS Products, continued ESWABI200PA Product Description UPC Code Catalog Number Intercom outdoor keypad. Weather resistant UV protected, aluminum color. 786685242262 ESWABI200PA 4 4 4 4 ESWABI200PB Intercom outdoor keypad. Weather resistant UV protected, brushed brass color. 786685242279 ESWABI200PB 4 4 4 ESWABI400 A-BUS door station. White 782116940233 ESWABI400 4 4 4 ESWABI500A Front door cover plate. Weather resistant UV protected, aluminum color. 786685242262 ESWABI500A 4 4 4 ESWABI500B Front door cover plate. Weather resistant UV protected, brushed brass color. 786685242279 ESWABI500B 4 4 4 4 ESWABIK311 Intercom kit. Kit includes one master keypad, three mini master keypads, one door station and one intercom module. White keypad 782116940240 ESWABIK311 Almond keypad 786685138725 ESWABIK311A 4 4 4 4 4 4 4 4 4 4 4 4 4 Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com V1-T4-13 4.1 StructuredWiringSolutions Enclosures 4 4 Structured Wiring Product Description UPC Code Catalog Number ESWI1200 12 x 14.5 x 4 inch install can. Allows room for three 6-inch modules. Panel includes a power receptacle and grounding bar. 782116469185 ESWI1200 ESWI1800 18 x 14.5 x 4 inch install can with 110V power. Allows room for five 6-inch modules. Panel includes a power receptacle and grounding bar. 782116904808 ESWI1800 ESWI2400 24 x 14.5 x 4 inch install can with 110V power. Allows room for seven 6-inch modules. Panel includes a power receptacle and grounding bar. 782116904822 ESWI2400 ESWI3600 36 x 14.5 x 4 inch install can with 110V power. Allows room for (11) 6-inch modules. Panel includes a power receptacle and grounding bar. 782116904846 ESWI3600 ESWI5400 54 x 14.5 x 4 inch install can with 110V power. Allows room for (17) 6-inch modules. Panel includes a power receptacle and grounding bar. 78211649284 ESWI5400 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 V1-T4-14 Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com Structured Wiring StructuredWiringSolutions 4.1 Enclosures, continued ESWFDB24 Product Description UPC Code Catalog Number 24-inch NEMA-3R D-marc box with plywood back. Meets the new SBC and Verizon specifications for outdoor fiber optic installations. Includes a power receptacle and grounding bar. 782116906581 ESWFDB24 4 4 4 4 ESWFDB32 32-inch NEMA-3R D-marc box with plywood back. Meets the new SBC and Verizon specifications for outdoor fiber optic installations. Includes a power receptacle and grounding bar. 782116906598 ESWFDB32 4 4 4 4 4 Covers ESWC1200 Product Description UPC Code Catalog Number 17 x 14 inch metal cover for install can ESWI1200. Includes venting for protection of installed electronic equipment. 782116469192 ESWC1200 4 4 4 4 ESWC1800 17 x 20 inch metal cover for install can ESWI1800. Includes venting for protection of installed electronic equipment. 782116904815 ESWC1800 4 4 4 ESWC2400 17 x 26 inch metal cover for install can ESWI2400. Includes venting for protection of installed electronic equipment. 782116904839 ESWC2400 4 4 4 4 ESWC3600 17 x 38 inch metal cover for install can ESWI3600. Includes venting for protection of installed electronic equipment. 782116904853 ESWC3600 4 4 4 4 4 4 4 4 4 4 Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com V1-T4-15 4.1 StructuredWiringSolutions Covers, continued 4 4 Structured Wiring Product Description UPC Code Catalog Number ESWC5400 17 x 56 inch metal cover for install can ESWI5400. Includes venting for protection of installed electronic equipment. 782116469291 ESWC5400 ESWC1800H 17 x 20 inch hinged cover for install can ESWI1800. One cover to a carton. 786685015163 ESWC1800H ESWC2400H 17 x 26 inch hinged cover for install can ESWI2400. One cover to a carton. 786685015170 ESWC2400H ESWC3600H 17 x 38 inch hinged cover for install can ESWI3600. One cover to a carton. 786685015187 ESWC3600H ESWC5400H 17 x 56 inch hinged cover for install can ESWI5400. One cover to a carton. 786685015132 ESWC5400H 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 4 V1-T4-16 Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com Structured Wiring StructuredWiringSolutions 4.1 Covers, continued ESWC1200P Product Description UPC Code Catalog Number 17 x 14 inch clear plastic cover for install can ESWI1200. Includes venting for protection of installed electronic equipment. 782116469208 ESWC1200P 4 4 4 4 ESWC1800P 17 x 20 inch clear plastic cover for install can ESWI1800. Includes venting for protection of installed electronic equipment. 782116630103 ESWC1800P 4 4 4 4 ESWC2400P 17 x 26 inch clear plastic cover for install can ESWI2400. Includes venting for protection of installed electronic equipment. 782116630110 ESWC2400P 4 4 4 4 ESWC3600P 17 x 38 inch clear plastic cover for install can ESWI3600. Includes venting for protection of installed electronic equipment. 782116630127 ESWC3600P 4 4 4 4 4 ESWC3600P 17 x 56 inch clear plastic cover for install can ESWI5400. Includes venting for protection of installed electronic equipment. 782116630134 ESWC5400P 4 4 4 4 4 4 4 4 4 4 4 4 4 Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com V1-T4-17 4.1 ESWR100CW 4 4 4 ESWR100TW5W 4 4 4 StructuredWiringSolutions Wall Plates 4 4 Structured Wiring ESWR100TW 4 Product Description UPC Code Catalog Number One-port wall outlet. One coax TV connection (RG6). White 782116894703 ESWR100CW Almond 782116894680 ESWR100CA Ivory 782116894697 ESWR100CI Wall hanging telephone wall plate. One CAT5e telephone/data connector. White 782116894383 ESWR100TW5W Almond 782116894369 ESWR100TW5A Ivory 782116894376 ESWR100TW5I One-port wall outlet. One RJ11 telephone connection (CAT3 rated). White 782116894765 ESWR100TW Almond 782116894741 ESWR100TA Ivory 782116894758 ESWR100TI One-port wall hanging outlet. One RJ11 telephone connection (CAT3 rated). White 782116894796 ESWR100TWW Almond 782116894772 ESWR100TWA Ivory 782116894789 ESWR100TWI One-port wall outlet. One RJ45 telephone/data connection (CAT5e rated). White 782116894734 ESWR100T5W Almond 782116894710 ESWR100T5A Ivory 782116894727 ESWR100T5I Two-port multimedia wall outlet. Telephone/data connection (CAT5e), one coax TV connection (RG6). White 782116894826 ESWR200W Almond 782116894802 ESWR200A Ivory 782116894819 ESWR200I Three-port multimedia wall outlet. One telephone/data connection (CAT5e), two coax TV connections (RG6). White 782116894857 ESWR300W Almond 782116894833 ESWR300A Ivory 782116894840 ESWR300I Four-port multimedia wall outlet. Two telephone/data connections (CAT5e), two coax TV connections (RG6). White 782116894888 ESWR400W Almond 782116894864 ESWR400A Ivory 782116894871 ESWR400I 4 4 ESWR100TWW 4 4 4 ESWR100T5W 4 4 4 ESWR200W 4 4 4 ESWR300W 4 4 4 ESWR400W 4 4 4 4 4 4 4 V1-T4-18 Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com Structured Wiring StructuredWiringSolutions 4.1 Wall Plates, continued ESWR600W ESWR110W Product Description UPC Code Catalog Number Six-port multimedia wall outlet. Two telephone/data connections (CAT5e), two blanks (may be populated with CAT5e, coax, or fiber optic connectors), two coax TV connections (RG6), White 782116894918 ESWR600W Almond 782116894895 ESWR600A Ivory 782116894901 ESWR600I One-port blank receptacle. (Blank face plates.) White 782116961924 ESWR110W Almond 782116894925 ESWR110A Ivory 782116894932 ESWR110I 4 4 4 4 4 4 4 ESWR110W One-port blank oversized plate. White 786685242224 ESWRO110W Almond 786685242231 ESWRO110A 4 4 4 ESWR210W ESWR210W ESWR310W ESWR410W ESWR610W Two-port blank receptacle. (Blank face plates.) White 782116894970 ESWR210W Almond 782116894956 ESWR210A Ivory 782116894963 ESWR210I 4 4 4 Two-port blank oversized plate. White 786685242248 ESWRO210W Almond 786685242255 ESWRO210A 4 4 4 Three-port blank receptacle. (Blank face plates.) White 782116895007 ESWR310W Almond 782116894987 ESWR310A Ivory 782116894994 ESWR310I Four-port blank receptacle. (Blank face plates.) White 782116895038 ESWR410W Almond 782116895014 ESWR410A Ivory 782116895021 ESWR410I Six-port blank receptacle. (Blank face plates.) White 782116895069 ESWR610W Almond 782116895045 ESWR610A Ivory 782116895052 ESWR610I 4 4 4 4 4 4 4 4 4 4 4 4 4 4 Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com V1-T4-19 4.1 Structured Wiring StructuredWiringSolutions Inserts 4 Product Description UPC Code Catalog Number Blank inserts for distribution panel. Sold in 12 pack. Yellow 782116895106 ESWBLY 4 Red 782116895083 ESWBLR 4 Blue 782116895076 ESWBLB White 782116895090 ESWBLW RG6 coax connectors for distribution panel. Sold in 12 pack. Yellow 782116895229 ESWMLC RJ45, CAT5e rated connectors for distribution panel. Sold in 12 pack. Blue 782116895212 ESWML5B CAT5e bezels for distribution panel. Sold in 12 pack. Orange 782116469215 ESWML5O CAT5e bezels for distribution panel. Sold in 12 pack. Blue 782116895113 ESWBZ5 Blank insert for receptacles. Sold in 12 pack. White 782116895144 ESWINSBLW Almond 782116895120 ESWINSBLA Ivory 782116895137 ESWINSBLI RJ11 wall plate insert. Sold in 12 pack. White 782116981335 ESWINS11W Almond 782116981328 ESWINS11A Ivory 782116981311 ESWINS11I CAT5e insert for receptacles. Sold in 12 pack. White 782116895175 ESWINS5W Almond 782116895151 ESWINS5A 4 Ivory 782116895168 ESWINS5I 4 Blue 782116981342 ESWINS5B Orange 782116981359 ESWINS5O 4 CAT6 insert for receptacles and patch modules. Sold in 12 pack. White 786685410609 ESWINS6W 4 Almond 786685410593 ESWINS6A Ivory 786685410616 ESWINS6I 4 RG6 coax inserts for receptacles. Sold in 12 pack. White 782116895205 ESWINSCW 4 Almond 782116895182 ESWINSCA Ivory 782116895199 ESWINSCI 4 4 ESWBLY ESWMLC 4 4 4 ESWML5B 4 4 4 ESWML5O 4 4 4 ESWBZ5 4 4 4 ESWINSBLW 4 4 4 4 4 4 4 V1-T4-20 Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com Structured Wiring StructuredWiringSolutions 4.1 Accessories 4 4 Patch Cords ESWPT308B Product Description UPC Code Catalog Number Two pair, CAT3 telephone patch cord. Blue 8 inches 4 782116895267 ESWPT308B 24 inches 782116895274 ESWPT324B 4 36 inches 782116894390 ESWPT336B 48 inches 782116469239 ESWPT348B 4 4 4 ESWPT508B Four pair, CAT5e telephone patch cord. Blue 8 inches 782116895281 ESWPT508B 24 inches 782116895298 ESWPT524B 36 inches 782116894406 ESWPT536B 48 inches 782116469246 ESWPT548B 4 4 4 4 ESWPT524O CAT5e telephone patch cord. Orange 24 inches 782116469253 ESWPT524O 36 inches 782116469260 ESWPT536O 48 inches 782116469277 ESWPT548O 4 4 4 4 ESWPC08 4 RG6-rated mini digital cable. Yellow 8 inches 782116895236 ESWPC08 24 inches 782116895243 ESWPC24 36 inches 782116895250 ESWPC36 48 inches 782116469222 ESWPC48 4 4 4 4 4 4 4 4 4 4 4 4 4 4 Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com V1-T4-21 Metering Products Group Metering and Meter Breaker Family 5.1 Single Meter Sockets Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2 5.4 5.7 5.10 V1-T5-29 V1-T5-34 V1-T5-35 V1-T5-37 V1-T5-39 V1-T5-48 V1-T5-59 V1-T5-65 V1-T5-75 V1-T5-83 V1-T5-86 V1-T5-87 Group Metering Systems for Residential and Commercial Applications . . . . . . . . . . . . Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type CCV 120/240V Tenant Main Circuit Breaker . . . . . . . . . . . . . . . . Type CV 120/240V Tenant Main Circuit Breaker . . . . . . . . . . . . . . . . . Meter Packs—1MP, 1MM and 3MM Main Tenant Circuit Breakers . . Main Service Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Surge Metering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Residential Meter Stacks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1MP, 1MM and 3MM Main Tenant Circuit Breakers . . . . . . . . . . . . . . Phase Balanced Stack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Commercial Meter Stack Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . 35MM, 37MM, 35SS and 37SS Main Tenant Circuit Breakers . . . . . . 5 5 5 5 5 Meter Breakers Residential Meter Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Non-EUSERC Combination Service Entrance Devices 100–200A Styles Meets EUSERC Requirements Service Entrance Devices 100–225A. West Coast All-In-One Design. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mechanical Interlock Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . House Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Commercial Safety Sockets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CH Style Renovation Solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Aluminum Meter Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 5 Communications Grounding Device (NEC 250.94) Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.9 V1-T5-27 Mechanical Lugs Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.8 V1-T5-25 Accessories and Cross-Reference Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 5 Residential Pedestals Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.6 V1-T5-18 Instrument Rated Sockets Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V1-T5-10 Multiple Position Horizontal Ganged Sockets Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 5 Commercial Lever Bypass Sockets Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.3 V1-T5-2 V1-T5-88 V1-T5-90 V1-T5-95 V1-T5-96 V1-T5-98 V1-T5-101 V1-T5-115 V1-T5-116 V1-T5-125 V1-T5-126 V1-T5-127 V1-T5-134 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Learn Online 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-1 5.1 5 Metering Products Single Meter Sockets Contents Single Meter Sockets Description 5 Features and Benefits . . . . . . . . . . . . . . . . . . . . . . Catalog Number Selection . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Product Description Single-Phase Three-Wire and Three-Phase Four-Wire 600 Vac Single Meter Sockets All Eaton sockets are rated 600 Vac maximum and either 100, 200 or 320A continuous. All have a minimum shortcircuit rating of 10,000 rms symmetrical amperes (watthour meter is not included in rating). All single meter sockets are UL labeled and are supplied in surface mounted outdoor enclosures. Confirm local utility acceptance prior to order entry. 5 5 5 5 5 5 5 5 5 5 5 5 5 5 V1-T5-2 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Page V1-T5-3 V1-T5-3 V1-T5-4 V1-T5-8 Metering Products Single Meter Sockets 5.1 Features and Benefits 5 5 Single Meter Sockets 5 Features Benefits Block assembly base exceeds 400 in-lbs of torque Provides durability under the most extreme installation circumstances One-piece, die-run enclosure Eliminates tampering and extends product life High visibility Eaton name embossed on cover Company identity and brand preference Knockouts are installer friendly Labor savings, less time needed for removing knockouts Oversized 7/8-inch diameter, heavy-duty, steel lug screws Stronger connection component facilitates a reliable wire termination Slide-nuts are captive Allow for ease in installation of conductors and eliminates lost components Horn bypass kit is field installable by changing out slide nut Less inventory required and field modifications are simple Integral triplex or quadplex ground extruded in neutral lug One piece for terminating incoming/outgoing neutral conductors, which increases integrity of connections 100% plated bridge with 4-point mounting Zinc chromate plated to provide superior corrosion resistance 5 5 5 5 5 kAIC rating Tested and UL listed up to 200 kAIC rating with specified overcurrent protection devices Provides a complete Eaton residential solution Adding meter sockets to the already existing (loadcenter, surge, breakers, generators and AC disconnect) product lines that we already provide, makes Eaton a one-stop shop for our customers residential and light commercial needs Copper-plated alloy jaws with reinforcing spring Steel reinforcing springs used in all socket jaws to maintain electrical connections 5 5 Catalog Number Selection 5 5 Single Meter Sockets RS Group UT RS 2 0 2 B CH Note: The “U” prefix is always used first followed by other prefixes required in alphabetical order. Standard Prefixes A = Aluminum enclosure B = Barrel lock provision, for an exposed INNER-TITE® or Brooks barrel lock; unit includes an internal lock receiver bracket F = Barrel Lock with guard provision, for a lock guard INNER-TITE or Brooks barrel lock; unit includes an internal lock receiver bracket G = Grounded fifth terminal (9 o’clock position) H = Horn bypass I = Inhibitor installed in wire connectors M = Temporary meter cover (waxed cardboard) N = No sealing ring (applies only to ring style sockets) R = Ring style socket S = Aluminum screw type sealing ring (applies only to ring style sockets) T = Grounding connector (#14–#2 Cu) for triplex ground TT = Two grounding connectors (#14–#2 Cu) for quadplex ground U = UL Underwriters Laboratories label Z = 5/16-inch hex head connector screw in place of slotted (100A only) RS = 2R-6R = 2H-6H = H = 5 Product Group Residential service, single position Residential service, multiple position Commercial or residential service, multiple position Commercial or residential service, single position 5 5 Standard Suffixes A = Solid top B = Small hub opening C = Small hub closing plate mounted L = 1.25-inch (31.8 mm) hub mounted M = 1.50-inch (38.1 mm) hub mounted N = 2.00-inch (50.8 mm) hub mounted P = 2.50-inch (63.5 mm) hub mounted T = Large hub opening hub U = Large hub cover plate hub mounted V = 2.50-inch (63.5 mm) large hub mounted Q = 3.00-inch (76.2 mm) large hub mounted R = 3.50-inch (88.9 mm) large hub mounted S = 4.00-inch (101.6 mm) large hub mounted Z = Large to small hub adapter mounted 5 5 5 5 5 5 Maximum Conductor (Line and Load) 0 = 0.38-inch stud connectors 1 = #2/0 connectors 2 = #250 kcmil connectors 3 = #350 kcmil connectors 5 5 5 Service Design 0 = Overhead 1 = Combination overhead/underground 2 = Underground, side wired 3 = Combination overhead/underground, side wired 5 5 Ampere Rating 1 = 100A 2 = 200A 5 = 150A 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-3 5.1 5 5 Metering Products Single Meter Sockets Product Selection URS212ACH Residential Ringless Type Cover 5 Ampere Rating Jaws Service Bypass Line Load Opening, Hub or Closure Plate Catalog Number 5 200 4 UG — 3/8-inch studs 3/8-inch studs Solid top UTRS240ACH 5 200 4 OH/UG — 3/8-inch studs 3/8-inch studs 3-5/16 hub cover plate UTRS2303CCH 200 4 UG — #8–350 kcmil #8–350 kcmil Solid top UTRS223ACH 200 4 UG — 3/8-inch studs 3/8-inch studs Solid top UTRS220ACH 200 4 OH/UG — #8–350 kcmil #8–350 kcmil 3-5/16 cover plate UTRS213CFLCH 5 200 4 OH/UG — #8–350 kcmil #8–350 kcmil 3-5/16 hub cover plate UTRS213CEPCH 5 200 4 OH/UG — #6–350 kcmil #6–350 kcmil 3-5/16 hub cover plate UGTRS213CE 200 4 OH/UG — #6–350 kcmil #6–350 kcmil 3-5/16 hub cover plate UTRS213CE 5 200 4 OH/UG — #6–350 kcmil #6–350 kcmil 3-5/16 hub opening UATRS213BCH 200 4 OH/UG — #6–350 kcmil #6–350 kcmil 3-5/16 hub opening URS213BCH 5 200 4 OH/UG — #6–350 kcmil #6–350 kcmil 3-5/16 hub opening UTRS213BE 5 200 4 UG — #8–350 kcmil #8–350 kcmil Solid top UTRS213AFLCH 200 4 UG — #8–350 kcmil #8–350 kcmil Solid top UTRS213ACH 5 200 4 OH/UG Horn #8–350 kcmil #8–350 kcmil 3-5/16 hub opening UTRS2138BCH 200 4 OH/UG — #8–250 kcmil #8–250 kcmil Solid top UTRS212ACH 5 200 4 OH/UG — #8–250 kcmil #8–250 kcmil 3-5/16 cover plate UTRS212CCH 5 Connections 200 4 OH/UG — #8–250 kcmil #8–250 kcmil 3-5/16 cover plate UTRS212CFLCH 200 4 OH/UG — #8–250 kcmil #8–250 kcmil 3-5/16 hub opening UTRS212BCH 5 200 4 OH — #8–250 kcmil #8–250 kcmil 2-inch bolt-on hub UTRS202NCH 200 4 OH — #8–250 kcmil #8–250 kcmil Small hub opening UATRS202BFLCH 1 5 200 4 OH/UG — #8–250 kcmil #8–250 kcmil 3-5/16 cover plate UTRS232CCH 200 4 OH — #8–2/0 cu/al #8–2/0 cu/al 3-5/16 hub opening UTRS202BCH 5 200 4 OH/UG — #8–250 kcmil #8–250 kcmil Solid top URS212ACH 5 200 4 OH — #8–250 kcmil #8–250 kcmil 2-inch bolt-on hub URS202NCH 200 5 OH Horn #8–250 kcmil #8–250 kcmil 3-5/16 hub opening URS202BDQCH 200 4 OH/UG Horn #8–350 kcmil #8–350 kcmil 3-5/16 hub cover plate UFHTRS213CCH 2 200 4 OH/UG Horn #8–350 kcmil #8–350 kcmil 3-5/16 hub opening UHTTRS213BCH 5 200 4 OH/UG Horn #8–350 kcmil #8–350 kcmil 3-5/16 hub cover plate UHTTRS213CCH 5 200 4 OH Horn #8–250 kcmil #8–250 kcmil 3-5/16 hub opening UHTTRS202BCH 200 5 OH/UG Horn #8–350 kcmil #8–350 kcmil 3-5/16 hub cover plate UHTRS233CCH 5 200 4 UG Horn #8–350 kcmil #8–350 kcmil Solid top UHTRS223ARHCH 200 4 UG Horn #8–350 kcmil #8–350 kcmil Solid top UFHTRS223ACH 5 200 5 UG Horn #8–350 kcmil #8–350 kcmil Solid top UGHTRS223ACH 5 200 4 UG Horn #8–350 kcmil #8–350 kcmil Solid top UHTTRS223ACH 200 4 UG Horn #8–350 kcmil #8–350 kcmil Solid top UHTRS223ACH 5 200 4 OH/UG Horn #6–350 kcmil #6–350 kcmil 3-5/16 hub opening UHTRS213CE 200 4 OH/UG Horn #6–350 kcmil #6–350 kcmil 3-5/16 hub opening UHTRS213BE 5 200 4 OH/UG Horn #8–350 kcmil #8–350 kcmil Solid top UHTRS213AE 200 4 OH Horn #8–350 kcmil #8–350 kcmil 3-5/16 hub opening UHTRS203BCH 200 4 OH Horn #8–250 kcmil #8–250 kcmil 3-5/16 hub opening UHTRS202BCH 200 4 OH/UG None #8–250 kcmil #8–250 kcmil 2-inch bolt-on hub URS202NPECCH 3 5 5 5 5 Notes 1 Aluminum enclosure. 2 Barrel lock. 3 PEC approved. 5 5 For dimensions, see Pages V1-T5-8 and V1-T5-9. V1-T5-4 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 5.1 Metering Products Single Meter Sockets Residential Ringless Type Cover, continued Connections Ampere Rating Jaws Service Bypass Line 200 4 OH/UG Horn #8–350 kcmil 200 4 OH/UG Horn 200 5 OH/UG 200 5 OH/UG 5 Load Opening, Hub or Closure Plate Catalog Number #8–350 kcmil Solid top UHIRS223ACVCH #8–350 kcmil #8–350 kcmil 3-5/16 hub opening UHIRS213BCVCH — #6–350 kcmil #6–350 kcmil Closure plate UGTRS213CE — #6–350 kcmil #6–350 kcmil Hub opening UGTRS213BE 200 5 OH/UG Horn #6–350 kcmil #6–350 kcmil Closure plate 786685217918 200 5 OH/UG Horn #6–350 kcmil #6–350 kcmil 3-5/16 hub opening UGHTRS213BE 200 5 OH/UG Horn #8–250 kcmil #8–250 kcmil 3-5/16 hub cover plate UGHRS212CKCCH 200 4 OH — #8–250 kcmil #8–250 kcmil 3-5/16 hub opening UFTRS202BCH 5 5 5 5 5 5 200 4 OH Horn #8–250 kcmil #8–250 kcmil 3-5/16 hub opening UFHTRS202BCH 200 4 UG Horn #8–350 kcmil #8–350 kcmil Solid top UBHTRS223ARHCH 200 4 UG Horn #8–350 kcmil #8–350 kcmil Solid top UBHRS223ACH 200 4 OH Horn #8–250 kcmil #8–250 kcmil 3-5/16 hub cover plate UBHRS202BCH 200 4 OH/UG — #8–350 kcmil #8–350 kcmil 3-5/16 hub opening UATRS213CFLCH 5 200 4 OH/UG Horn #8–350 kcmil #8–350 kcmil 3-5/16 hub cover plate UAHTRS233CSHCH 200 4 UG Horn #8–350 kcmil #8–350 kcmil Solid top UAHTRS223AFLCH 200 4 OH Horn #8–250 kcmil #8–250 kcmil 3-5/16 hub opening UAHTRS202BFLCH 200 4 OH/UG — #8–350 kcmil #8–350 kcmil 3-5/16 hub closure plate U92197CCCPLCH 200 4 OH/UG — #8–350 kcmil #8–350 kcmil 3-5/16 hub closure plate 1009928CH 200 4 OH/UG Horn #8–250 kcmil #8–250 kcmil Solid top 1009874ACH 200 4 UG — 3/8-inch studs 3/8-inch studs Solid top 1009046CH 200 4 UG Horn #8–350 kcmil #8–350 kcmil Solid top 1008941CH 200 4 UG Horn #8–350 kcmil #8–350 kcmil Solid top 1008940CH 200 4 UG Horn #8–350 kcmil #8–350 kcmil Solid top 1008827CH 200 4 UG Horn #8–350 kcmil #8–350 kcmil Solid top 1008819CH 200 4 UG Horn #8–350 kcmil #8–350 kcmil Solid top 1008717CH 200 4 UG — #8–350 kcmil #8–350 kcmil Solid top 1008617CH 200 4 OH/UG Horn #8–350 kcmil #8–350 kcmil 3-5/16 hub opening 1007817CH 200 4 OH Horn #8–250 kcmil #8–250 kcmil 3-5/16 hub opening 1007699CH 200 4 OH Horn #8–250 kcmil #8–250 kcmil 3-5/16 hub opening 1007665CH 200 4 UG Horn #8–350 kcmil #8–350 kcmil Solid top 1007588CH 200 4 OH/UG — 3/8-inch studs 3/8-inch studs 3-5/16 hub opening 1007448ACH 200 4 UG Horn #8–350 kcmil #8–350 kcmil Solid top 1004884ARHCH 1 200 4 UG Horn #8–350 kcmil #8–350 kcmil Solid top 1004884ACH 200 4 OH/UG — #8–#250 kcmil #8–#250 kcmil 3-5/16 hub cover plate 1004710ECH 200 4 OH — N/A N/A N/A 1004709DCH 200 4 OH Horn #8–#250 kcmil #8–#250 kcmil 2-inch bolt-on hubs 1004455BCH 200 4 OH Horn #8–250 kcmil #8–250 kcmil 3-5/16 hub opening 1004161ACH 200 4 OH/UG Horn #8–350 kcmil #8–350 kcmil 3-5/16 hub opening 1004159ACH 200 4 OH/UG — #8–350 kcmil #8–350 kcmil Hub closure plate 1008826ACH 2 200 4 OH/UG Lever #6–350 kcmil #6–350 kcmil Hub closure plate 1006352CCH 2 200 5 OH Horn #8–250 kcmil #8–250 kcmil 3-5/16 hub opening 1003879ACH 200 5 OH/UG Horn #8–350 kcmil #8–350 kcmil 3-5/16 hub opening 1003878ACH 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Notes 1 Right hand incoming. 2 Austin Energy approved. 5 For dimensions, see Pages V1-T5-8 and V1-T5-9. 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-5 5.1 5 URS101BCH 5 5 5 5 5 Metering Products Single Meter Sockets Residential Ringless Type Cover, continued Connections Ampere Rating Jaws Service Bypass Line Load Opening, Hub or Closure Plate Catalog Number 150 4 OH/UG — #8–2/0 AWG #8–2/0 AWG Hub closure plate 1004326DCH 1 150 4 OH/UG — #8–250 kcmil #8–250 kcmil Hub opening UTRS502BCH 150 4 OH — #8–250 kcmil #8–250 kcmil 3-5/16 hub opening UTRS502BCH 150 4 OH — #8–250 kcmil #8–250 kcmil 3-5/16 hub cover plate UTRS502CCH 1006385BCH 125 4 UG — N/A N/A N/A 125 4 OH/UG — #8–2/0 cu/al #8–2/0 cu/al 3-5/16 hub opening UTRS111BCH 125 4 OH — #8–2/0 cu/al #8–2/0 cu/al 3-5/16 hub opening UBTRS101BCH 125 4 OH — #8–2/0 cu/al #8–2/0 cu/al 1-1/4-inch bolt-on hub UTRS101LCH 125 4 OH — #8–2/0 cu/al #8–2/0 cu/al 3-5/16 hub cover plate UTRS101CE 125 4 OH — #8–2/0 cu/al #8–2/0 cu/al 3-5/16 hub opening UTRS101BE 125 4 OH — #8–2/0 #8–2/0 3-5/16 hub cover plate URS101CCPLCH 125 4 OH Horn cu/al with 1/2-inch hex head wire clamping screw cu/al with 3-5/16 hub cover plate 1/2-inch hex head wire clamping screw URS101BDQCH 5 125 4 OH — #8–2/0 #8–2/0 3-5/16 hub opening URS101BCPLCH 125 4 OH — #8–2/0 #8–2/0 3-5/16 hub opening URS101BCH 5 125 4 OH Horn #8–2/0 #8–2/0 3-5/16 hub opening UHTTRS101BCH 125 4 OH/UG Horn #8–250 kcmil #8–250 kcmil 3-5/16 hub opening UHTRS111BCH 125 4 OH Horn #8–2/0 #8–2/0 1.25-inch hub mounted UHTRS101LCH 125 4 OH Horn #8–2/0 #8–2/0 Closure plate UHTRS101CE 125 4 OH Horn #8–2/0 #8–2/0 3-5/16 hub opening UHTRS101BE 125 5 OH/UG — #8–2/0 #8–2/0 3-5/16 hub cover plate UGRS10101CKCCH 125 5 OH/UG — #8–2/0 #8–2/0 3-5/16 hub cover plate UGHTRS111CCH 5 125 5 OH — #8–2/0 #8–2/0 3-5/16 hub opening UGHTRS101BCH 5 125 4 OH — #8–2/0 #8–2/0 3-5/16 hub cover plate UBHRS101BCH 125 4 OH/UG — #8–2/0 #8–2/0 3-5/16 hub cover plate UATZRS101CFLCH 5 5 5 5 5 5 5 125 4 OH — #8–2/0 #8–2/0 3-5/16 hub cover plate UATRS101CCH 125 4 OH — #8–2/0 #8–2/0 3-5/16 hub opening 1008947CH 5 125 4 UG N/A N/A N/A N/A 1005826ACH 5 125 4 OH — #8–2/0 #8–2/0 1-1/4-inch bolt-on hub 1004931BCH 125 4 OH — #8–2/0 #8–2/0 3-5/16 hub opening 1004162ACH 5 125 5 OH — #8–2/0 #8–2/0 3-5/16 hub opening 1003880ACH 125 4 OH — #8–2/0 #8–2/0 3-5/16 hub opening UTZRS101BFLCH 5 125 4 OH — #8–2/0 #8–2/0 3-5/16 hub closure plate UTZRS101CFLCH 125 5 OH Horn #8–2/0 #8–2/0 Hub opening UTRS101CEPSEG 2 100 4 OH — #8–2/0 #8–2/0 3-5/16 hub opening 1009079CH 200 5 OH/UG Horn #8–350 kcmil #8–350 kcmil Hub closure plate UTRS213CEPSEG 2 5 5 5 Notes 1 Austin Energy approved. 2 PSE&G approved. 5 For dimensions, see Pages V1-T5-8 and V1-T5-9. 5 5 5 5 5 V1-T5-6 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Single Meter Sockets 5.1 Residential Ring Type Cover Connections Ampere Rating Jaws Service Line 200 4 UG #8–350 kcmil 200 4 OH/UG 200 4 200 5 Load Opening, Hub or Closure Plate Catalog Number #8–350 kcmil Solid top URTRS223ACH #8–350 kcmil #8–350 kcmil 3-5/16 hub cover plate URRS213CCH OH/UG #8–350 kcmil #8–350 kcmil 2 inch hub mounted URTRS213NEUSCH 4 OH/UG #8–350 kcmil #8–350 kcmil 3-5/16 hub cover plate URTRS213CEUSCH 200 4 OH/UG #8–350 kcmil #8–350 kcmil 3-5/16 hub cover plate 1009424CH 200 4 OH/UG #8–350 kcmil #8–350 kcmil Knockouts 1009449CH 200 4 OH #8–350 kcmil #8–350 kcmil 3-5/16 hub opening URSTRS203BCH 200 4 OH #8–250 kcmil #8–250 kcmil 3-5/16 hub cover plate URS212BCRCH 200 4 OH/UG #8–250 kcmil #8–250 kcmil 3-5/16 hub cover plate URTRS202BCH 200 4 OH #8–250 kcmil #8–250 kcmil 3-5/16 hub opening URTRS213BE 200 4 OH/UG #6–350 kcmil #6–350 kcmil Hub opening URTRS202BCH 200 4 OH/UG #6–350 kcmil #6–350 kcmil Closure plate URTRS213CE 200 4 UG #6–350 kcmil #6–350 kcmil 3-5/16 hub opening URTRS213BEUSCH 200 4 OH #8–250 kcmil #8–250 kcmil 2-inch hub mounted URTRS202NEUSCH 200 4 OH #8–250 kcmil #8–250 kcmil 3-5/16 hub opening UNRRS202BEUSCH 200 4 OH/UG #6–350 kcmil #6–350 kcmil Closure plate UNRRS213CEUSE 200 4 OH #8–250 kcmil #8–250 kcmil Hub opening UNRRS213BEUSE 200 4 UG #6–350 kcmil #6–350 kcmil Solid top UNRRS213AEUSE 200 4 OH/UG #6–250 kcmil #6–250 kcmil 5x5 hub opening 3-5/16 adapter plate 1009097CH 125 4 OH #8–2/0 cu/al #8–2/0 cu/al 3-5/16 hub opening URS101BCRCH 125 4 OH #8–2/0 cu/al #8–2/0 cu/al 1-1/4-inch bolt-on hub URRS101LCH 125 4 OH #8–2/0 cu/al #8–2/0 cu/al Hub cover plate URTRS101BE 125 4 OH #8–2/0 cu/al #8–2/0 cu/al Hub cover plate URTRS101CE 125 4 OH #8–2/0 cu/al #8–2/0 cu/al 3-5/16 hub cover plate UNRRS101BEUSE 125 4 OH #8–2/0 cu/al #8–2/0 cu/al Closure plate UNRRS101CEUSE 125 4 OH/UG #8–2/0 cu/al #8–2/0 cu/al 3-5/16 hub cover plate UNRRS111BEUSE 125 4 UG #8–2/0 cu/al #8–2/0 cu/al Solid top UNRRS111AEUSE 125 4 OH #8–2/0 cu/al #8–2/0 cu/al 3-5/16 hub opening URSTRS101BCH 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Note For dimensions, see Pages V1-T5-8 and V1-T5-9. 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-7 5.1 5 Metering Products Single Meter Sockets Dimensions Approximate Dimensions in Inches (mm) 5 5 Residential Ringless Type Cover Residential Ringless Type Cover, continued Catalog Number Height Width Depth Catalog Number Height Width UTRS240ACH 18.63 (473.2) 13.00 (330.2) 4.94 (125.5) UHIRS213BCVCH 15.00 (381.0) 11.00 (279.4) 4.38 (111.3) 5 UTRS2303CCH 20.00 (508.0) 13.00 (330.2) 4.94 (125.5) UGTRS213CE 15.13 (384.3) 11.25 (285.8) 4.50 (114.3) UTRS223ACH 13.00 (330.2) 13.00 (330.2) 4.94 (125.5) UGTRS213BE 15.13 (384.3) 11.25 (285.8) 4.50 (114.3) 5 UTRS220ACH 15.13 (384.3) 13.00 (330.2) 4.94 (125.5) 786685217918 15.13 (384.3) 11.25 (285.8) 4.50 (114.3) UTRS213CFLCH 15.00 (381.0) 11.00 (279.4) 4.37 (111.0) UGHTRS213BE 15.13 (384.3) 11.25 (285.8) 4.50 (114.3) UTRS213CEPCH 15.00 (381.0) 11.00 (279.4) 4.37 (111.0) UGHRS212CKCCH 14.00 (355.6) 11.00 (279.4) 4.38 (111.3) 5 UGTRS213CE 15.13 (384.3) 11.25 (285.8) 4.50 (114.3) UFTRS202BCH 14.00 (355.6) 8.00 (203.2) 4.38 (111.3) UTRS213CE 15.13 (384.3) 11.25 (285.8) 4.50 (114.3) UFHTRS202BCH 14.00 (355.6) 8.00 (203.2) 4.38 (111.3) 5 UATRS213BCH 15.13 (384.3) 11.25 (285.8) 4.50 (114.3) UBHTRS223ARHCH 13.00 (330.2) 13.00 (330.2) 4.94 (125.5) URS213BCH 15.00 (381.0) 11.00 (279.4) 4.36 (110.7) UBHRS223ACH 13.00 (330.2) 13.00 (330.2) 4.94 (125.5) 5 UTRS213BE 15.13 (384.3) 11.25 (285.8) 4.50 (114.3) UBHRS202BCH 14.00 (355.6) 8.00 (203.2) 4.38 (111.3) 5 UTRS213AFLCH 15.00 (381.0) 11.00 (279.4) 4.37 (111.0) UATRS213CFLCH 15.00 (381.0) 11.00 (279.4) 4.38 (111.3) UTRS213ACH 15.00 (381.0) 11.00 (279.4) 4.36 (110.7) UAHTRS233CSHCH 17.13 (435.1) 13.00 (330.2) 4.94 (125.5) UTRS2138BCH 20.00 (508.0) 13.00 (330.2) 4.94 (125.5) UAHTRS223AFLCH 13.00 (330.2) 13.00 (330.2) 4.94 (125.5) UTRS212ACH 14.00 (355.6) 11.00 (279.4) 4.37 (111.0) UAHTRS202BFLCH 14.00 (355.6) 8.00 (203.2) 4.38 (111.3) 5 UTRS212CCH 14.00 (355.6) 11.00 (279.4) 4.36 (110.7) U92197CCCPLCH 14.13 (358.9) 13.00 (330.2) 4.94 (125.5) 5 UTRS212CFLCH 14.00 (355.6) 11.00 (279.4) 4.36 (110.7) 1009928CH 15.00 (381.0) 11.00 (279.4) 4.38 (111.3) UTRS212BCH 14.00 (355.6) 11.00 (279.4) 4.36 (110.7) 1009874ACH 15.00 (381.0) 13.00 (330.2) 4.94 (125.5) 5 UTRS202NCH 14.00 (355.6) 8.00 (203.2) 4.36 (110.7) 1009046CH 20.75 (527.1) 9.00 (228.6) 4.94 (125.5) 14.00 (355.6) 8.00 (203.2) 4.36 (110.7) 1008941CH 17.13 (435.1) 13.00 (330.2) 4.94 (125.5) 5 UTRS232CCH 17.12 (434.8) 13.00 (330.2) 4.93 (125.2) 1008940CH 17.13 (435.1) 13.00 (330.2) 4.94 (125.5) 5 UTRS202BCH 14.00 (355.6) 8.00 (203.2) 4.36 (110.7) 1008827CH 13.00 (330.2) 13.00 (330.2) 4.94 (125.5) URS212ACH 14.00 (355.6) 11.00 (279.4) 4.38 (111.3) 1008819CH 13.00 (330.2) 13.00 (330.2) 4.94 (125.5) 5 URS202NCH 14.00 (355.6) 8.00 (203.2) 4.38 (111.3) 1008717CH 15.00 (381.0) 13.00 (330.2) 4.94 (125.5) URS202BDQCH 14.00 (355.6) 8.00 (203.2) 4.38 (111.3) 1008617CH 15.00 (381.0) 13.00 (330.2) 4.94 (125.5) 5 UFHTRS213CCH 2 15.00 (381.0) 11.00 (279.4) 4.38 (111.3) 1007817CH 15.00 (381.0) 11.00 (279.4) 4.38 (111.3) UHTTRS213BCH 15.00 (381.0) 11.00 (279.4) 4.38 (111.3) 1007699CH 14.00 (355.6) 8.00 (203.2) 4.38 (111.3) UHTTRS213CCH 15.00 (381.0) 11.00 (279.4) 4.38 (111.3) 1007665CH 14.00 (355.6) 8.00 (203.2) 4.38 (111.3) UHTTRS202BCH 14.00 (355.6) 8.00 (203.2) 4.38 (111.3) 1007588CH 13.00 (330.2) 13.00 (330.2) 4.94 (125.5) UHTRS233CCH 17.13 (435.1) 13.00 (330.2) 4.94 (125.5) 1007448ACH 19.00 (482.6) 11.00 (279.4) 4.38 (111.3) 5 5 5 5 5 5 UATRS202BFLCH 1 3 Depth UHTRS223ARHCH 13.00 (330.2) 13.00 (330.2) 4.94 (125.5) 1004884ARHCH 13.00 (330.2) 13.00 (330.2) 4.93 (125.2) UFHTRS223ACH 13.00 (330.2) 13.00 (330.2) 4.94 (125.5) 1004884ACH 13.00 (330.2) 13.00 (330.2) 4.93 (125.2) 5 UGHTRS223ACH 13.00 (330.2) 13.00 (330.2) 4.94 (125.5) 1004710ECH 14.00 (355.6) 11.00 (279.4) 4.38 (111.3) 5 UHTTRS223ACH 13.00 (330.2) 13.00 (330.2) 4.94 (125.5) 1004709DCH N/A N/A N/A UHTRS223ACH 13.00 (330.2) 13.00 (330.2) 4.94 (125.5) 1004455BCH 15.00 (381.0) 8.00 (203.2) 4.38 (111.3) UHTRS213CE 15.00 (381.0) 11.00 (279.4) 4.38 (111.3) 1004161ACH 14.00 (355.6) 8.00 (203.2) 4.38 (111.3) UHTRS213BE 15.00 (381.0) 11.00 (279.4) 4.38 (111.3) 1004159ACH 15.00 (381.0) 11.00 (279.4) 4.38 (111.3) 5 UHTRS213AE 15.00 (381.0) 11.00 (279.4) 4.38 (111.3) 1003879ACH 15.00 (381.0) 8.00 (203.2) 4.38 (111.3) 5 UHTRS203BCH 15.00 (381.0) 8.00 (203.2) 4.38 (111.3) 1003878ACH 15.00 (381.0) 11.00 (279.4) 4.38 (111.3) UHTRS202BCH 14.00 (355.6) 8.00 (203.2) 4.38 (111.3) UTRS502BCH 14.00 (355.6) 8.00 (203.2) 4.38 (111.3) UHIRS223ACVCH 13.00 (330.2) 13.00 (330.2) 4.94 (125.5) Notes 1 Aluminum enclosure. 2 Barrel lock. 3 Right hand incoming. 5 5 5 5 V1-T5-8 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 5.1 Metering Products Single Meter Sockets Approximate Dimensions in Inches (mm) 5 Residential Ringless Type Cover, continued 5 Residential Ring Type Cover Catalog Number Height Width Depth Catalog Number Height Width Depth UTRS502BCH 14.00 (355.6) 8.00 (203.2) 4.36 (110.7) URTRS223ACH 13.00 (330.2) 13.00 (330.2) 4.93 (125.2) UTRS502CCH 14.00 (355.6) 8.00 (203.2) 4.36 (110.7) URRS213CCH 15.00 (381.0) 11.00 (279.4) 4.38 (111.3) 1006385BCH N/A N/A N/A URTRS213NEUSCH 15.00 (381.0) 11.00 (279.4) 4.38 (111.3) UTRS111BCH 14.00 (355.6) 11.00 (279.4) 4.36 (110.7) URTRS213CEUSCH 15.00 (381.0) 11.00 (279.4) 4.38 (111.3) UBTRS101BCH 10.88 (276.4) 8.00 (203.2) 3.50 (88.9) 1009424CH 15.00 (381.0) 11.00 (279.4) 4.38 (111.3) UTRS101LCH 10.88 (276.4) 8.00 (203.2) 3.50 (88.9) 1009449CH 18.31 (465.1) 14.19 (360.4) 5.13 (130.3) UTRS101CE 11.05 (280.7) 8.22 (208.8) 3.61 (91.7) URSTRS203BCH N/A N/A N/A UTRS101BE 11.05 (280.7) 8.22 (208.8) 3.61 (91.7) URS212BCRCH 14.00 (355.6) 8.00 (203.2) 4.38 (111.3) URS101CCPLCH 10.88 (276.4) 8.00 (203.2) 3.50 (88.9) URTRS202BCH 14.00 (355.6) 11.00 (279.4) 4.38 (111.3) URS101BDQCH 10.88 (276.4) 8.00 (203.2) 3.50 (88.9) URTRS213BE 14.00 (355.6) 8.00 (203.2) 4.50 (114.3) URS101BCPLCH 10.88 (276.4) 8.00 (203.2) 3.50 (88.9) URTRS202BCH 15.13 (384.3) 11.25 (285.8) 4.50 (114.3) URS101BCH 10.88 (276.4) 8.00 (203.2) 3.50 (88.9) URTRS213CE 15.13 (384.3) 11.25 (285.8) 4.50 (114.3) UHTTRS101BCH 10.88 (276.4) 8.00 (203.2) 3.50 (88.9) URTRS213BEUSCH 15.13 (384.3) 11.25 (285.8) 4.50 (114.3) UHTRS111BCH 14.00 (355.6) 11.00 (279.4) 4.38 (111.3) URTRS202NEUSCH 14.00 (355.6) 8.00 (203.2) 4.38 (111.3) UHTRS101LCH 10.88 (276.4) 8.00 (203.2) 3.50 (88.9) UNRRS202BEUSCH 14.00 (355.6) 8.00 (203.2) 4.38 (111.3) UHTRS101CE 11.05 (280.7) 8.22 (208.8) 3.61 (91.7) UNRRS213CEUSE 15.13 (384.3) 11.25 (285.8) 4.50 (114.3) UHTRS101BE 11.05 (280.7) 8.22 (208.8) 3.61 (91.7) UNRRS213BEUSE 15.13 (384.3) 11.25 (285.8) 4.50 (114.3) UGRS10101CKCCH 12.00 (304.8) 8.00 (203.2) 3.50 (88.9) UNRRS213AEUSE 15.13 (384.3) 11.25 (285.8) 4.50 (114.3) UGHTRS111CCH 14.00 (355.6) 11.00 (279.4) 4.36 (110.7) 1009097CH 19.00 (482.6) 13.00 (330.2) 5.25 (133.4) UGHTRS101BCH 10.88 (276.4) 8.00 (203.2) 3.50 (88.9) URS101BCRCH 10.88 (276.4) 8.00 (203.2) 3.50 (88.9) UBHRS101BCH 10.88 (276.4) 8.00 (203.2) 3.50 (88.9) URRS101LCH 10.88 (276.4) 8.00 (203.2) 3.50 (88.9) UATZRS101CFLCH 10.88 (276.4) 8.00 (203.2) 3.50 (88.9) URTRS101BE 11.00 (279.4) 8.25 (209.6) 3.63 (92.2) UATRS101CCH 10.87 (276.1) 8.00 (203.2) 3.50 (88.9) URTRS101CE 11.00 (279.4) 8.25 (209.6) 3.63 (92.2) 1008947CH 10.89 (276.6) 8.00 (203.2) 3.50 (88.9) UNRRS101BEUSE 10.88 (276.4) 8.00 (203.2) 3.50 (88.9) 1005826ACH N/A N/A N/A UNRRS101CEUSE 10.88 (276.4) 8.00 (203.2) 3.50 (88.9) 1004931BCH 10.88 (276.4) 8.00 (203.2) 3.50 (88.9) UNRRS111BEUSE 14.00 (355.6) 11.00 (279.4) 4.38 (111.3) 1004162ACH 10.89 (276.6) 8.00 (203.2) 3.50 (88.9) URSTRS101BCH 10.88 (276.4) 8.00 (203.2) 3.50 (88.9) 1003880ACH 10.89 (276.6) 8.00 (203.2) 3.50 (88.9) UTZRS101BFLCH N/A N/A N/A UTZRS101CFLCH N/A N/A N/A 1009079CH 23.75 (603.3) 8.00 (203.2) 3.48 (88.4) 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-9 5.2 5 Metering Products Commercial Lever Bypass Sockets Contents Commercial Lever Bypass Sockets Description 5 Catalog Number Selection . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 5 5 5 5 5 5 5 5 5 Product Description ● 5 ● 5 ● 5 5 5 ● ● ● Heavy-duty, lever bypass, jaw clamping ringless meter socket design 200A and 320A styles available Single-phase or three-phase 4, 5 or 7 terminal available 600 Vac maximum rating Multiple service design offerings Standards and Certifications ● UL 414 listed and recognized 5 5 5 5 5 5 5 5 5 5 5 5 5 V1-T5-10 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Page V1-T5-11 V1-T5-12 V1-T5-16 Metering Products Commercial Lever Bypass Sockets 5.2 Catalog Number Selection 5 5 Single Meter Sockets H Group 5 UT H 4 2 0 3 B CH Note: The “U” prefix is always used first followed by other prefixes required in alphabetical order. Standard Prefixes A = Aluminum enclosure B = Barrel lock provision, for an exposed INNER-TITE or Brooks barrel lock; unit includes an internal lock receiver bracket F = Barrel Lock with guard provision, for a lock guard INNER-TITE or Brooks barrel lock; unit includes an internal lock receiver bracket G = Grounded fifth terminal (9 o’clock position) H = Horn bypass I = Inhibitor installed in wire connectors M = Temporary meter cover (waxed cardboard) N = No sealing ring (applies only to ring style sockets) R = Ring style socket S = Aluminum screw type sealing ring (applies only to ring style sockets) T = Grounding connector (#14–#2 Cu) for triplex ground TT = Two grounding connectors (#14–#2 Cu) for quadplex ground U = UL label Z = 5/16-inch hex head connector screw in place of slotted (100A only) RS 2R-6R 2H-6H H = = = = 5 Standard Suffixes Product Group Residential service, single position Residential service, multiple position Commercial or residential service, multiple position Commercial or residential service, single position Jaw Quantity 4 = 4 terminals 5 = 5 terminals 7 = 7 terminals 5 A = Solid top B = Small hub opening C = Small hub closing plate mounted L = 1.25-inch (31.8 mm) hub mounted M = 1.50-inch (38.1 mm) hub mounted N = 2.00-inch (50.8 mm) hub mounted P = 2.50-inch (63.5 mm) hub mounted T = Large hub opening hub U = Large hub cover plate hub mounted V = 2.50-inch (63.5 mm) large hub mounted Q = 3.00-inch (76.2 mm) large hub mounted R = 3.50-inch (88.9 mm) large hub mounted S = 4.00-inch (101.6 mm) large hub mounted Z = Large to small hub adapter mounted 5 5 5 5 5 Maximum Conductor (Line & Load) 0 = 0.38-inch stud connectors 3 = #350 kcmil connectors 5 = #500 kcmil connectors 6 = #600 kcmil connectors 7 = #750 kcmil connectors 8 = Dual #250 kcmil connectors 9 = Dual #350 kcmil connectors 5 5 5 5 Service Design 0 = Overhead 1 = Combination overhead/underground 2 = Underground, side wired 3 = Combination overhead/underground, side wired 5 5 Ampere Rating 2 = 200A 3 = 320A 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-11 5.2 Metering Products Commercial Lever Bypass Sockets 5 Product Selection 5 Commercial Lever Bypass 5 Ampere Rating Jaws Service Bypass Line 5 320 7 OH/UG Lever 320 7 OH Lever 5 320 7 OH/UG 320 7 OH/UG 5 Connections Load Opening, Hub or Closure Plate Catalog Number #4-600 kcmil #4–600 kcmil 5x5 hub opening UTTH7336TCH #600 kcmil Dual #6–350 5x5 hub opening UTH73069THLCH Lever #14–1/0 cu/al #6–350 kcmil 5x5 hub cover plate UTH73369UHLCH Lever #14–1/0 cu/al #6–350 kcmil 5x5 hub opening UTH73369THLCH 320 7 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub cover plate UFTH7330UCH 5 320 7 OH/UG Lever #600 kcmil #600 kcmil 5x5 hub opening UTH7336TCH 320 7 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub cover plate UTH7330UCH 5 320 7 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub cover plate UTH7330UFLCH 320 7 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub cover plate UATH7330UFLCH 1 320 7 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening UH7330TCPLCH 5 5 320 7 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening UTH7330TCH 320 7 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub-inch opening UTTH7330TCH 5 320 7 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub cover plate UH7300UCPLCH 320 7 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub cover plate UTH7300UCH 320 7 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening UTH7300TCH 320 7 OH/UG Lever #6–350 kcmil #6–350 kcmil Hub closure plate 1006353CCH 2 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 320 5 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub cover plate UTH5330UFLCH 320 5 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub cover plate UTH5330UCH 320 5 OH Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening UTH5300TCH 320 5 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub cover plate UATH5330UFLCH 320 4 OH/UG lever #4–600 kcmil #4–600 kcmil Hub closure plate 1010468CH 2 320 4 UG Lever 3/8-inch studs 3/8-inch studs Solid top UTH4320ACH 320 4 UG Lever 3/8-inch studs Dual #6–350 Solid top UTH43209ACH 320 4 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub cover plate UTH4339UCH 320 4 OH/UG Lever #6–250 kcmil #6–250 kcmil 5x5 hub cover plate UTH4338UCH 320 4 OH/UG Lever #4–600 kcmil #4–600 kcmil 5x5 hub cover plate UTH4336UCH 320 4 OH/UG Lever #4–600 kcmil #4–600 kcmil 5x5 hub opening UTH4336TCH 320 4 OH/UG Lever #4–600 kcmil #6–350 kcmil 5x5 hub cover plate UTH43369UCH UTH43369TCH 320 4 OH/UG Lever #4–600 kcmil #6–350 kcmil 5x5 hub opening 320 4 OH/UG Lever 3/8-inch studs 3/8-inch studs 3-5/16 hub cover plate UTTH4330UCH 320 4 OH/UG Lever 3/8-inch studs 3/8-inch studs 3-5/16 hub cover plate UTH4330UCH 320 4 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening UBTH4330TCH 320 4 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening UTH4330TCH 320 4 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 cover plate UTH4300UCH 320 4 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening UTH4300TCH 320 5 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub cover plate UH5300UKCCH 320 4 OH/UG Lever #6–250 kcmil #4–600 kcmil 5x5 hub cover plate UH43168UCPLCH 320 4 OH/UG Lever #4–600 kcmil #6–250 kcmil 5x5 hub cover plate UH43068TCPLCH 320 5 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub cover plate UGTH4330UCH 320 5 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening UGTH4330TCH 320 7 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening UFTH7330TCH 320 4 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening UFTH4330TCH 5 Notes 1 Aluminum enclosure. 2 Austin Energy approved. 5 For dimensions, see Pages V1-T5-16 and V1-T5-17. V1-T5-12 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Commercial Lever Bypass Sockets 5.2 Commercial Lever Bypass, continued Connections Ampere Rating Jaws Service Bypass Line 320 7 OH/UG Lever #4–600 kcmil 320 5 OH/UG Lever 320 4 OH/UG Lever 320 4 OH/UG 320 4 320 4 320 4 OH/UG Lever Dual #6–350 320 4 OH/UG Lever Dual #6–350 320 4 OH/UG Lever 3/8-inch studs 320 4 OH/UG Lever 320 7 OH/UG Lever 320 4 UG 320 4 320 4 320 5 Load Opening, Hub or Closure Plate Catalog Number #4–600 kcmil 5x5 hub opening UATH7336TCH 3/8-inch studs 3/8-inch studs 5x5 hub cover plate UATH5330UFLCH #4–600 kcmil #4–600 kcmil 5x5 hub opening UATH4336TCH Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening UATH4330TCH OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub cover plate 1009788CH OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub cover plate 1009788ACH 1 Dual #6–350 (2) 5x5 hub cover plates 1009760ACH Dual #6–350 5x5 hub cover plate 1009722CH 3/8-inch studs 5x5 hub cover plate 782116975945 3/8-inch studs 3/8-inch studs 5x5 hub cover plate 1009260CH #4–600 kcmil/Dual 1/0–250 kcmil cu/al #4–600 kcmil/Dual 1/0–250 kcmil cu/al 5x5 hub opening 1009181CH Lever #6–350 kcmil #6–350 kcmil Solid top 1009018CH OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening 1008950CH OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening 1008948CH 4 UG Lever 3/8-inch studs 3/8-inch studs Solid top 1008848CH 320 4 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening 1008837CH 320 4 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening 1008836CH 320 7 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening 1008798CH 320 4 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening 1008793CH 320 5 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening 1008792CH 320 7 OH/UG Lever #4–600 kcmil/Dual 1/0–250 kcmil cu/al #4–600 kcmil/Dual 1/0–250 kcmil cu/al 5x5 hub opening 1008543CH 5 320 4 OH/UG Lever #4–600 kcmil cu/al #4–600 kcmil cu/al 5x5 hub opening 1008541CH 320 4 UG Lever N/A N/A Solid top 1008540CH 5 320 4 OH/UG Lever #4–600 kcmil cu/al #4–600 kcmil cu/al Solid top 1008435CH 320 4 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening 1008191CH 320 4 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub opening 1008068CH 320 4 OH/UG Lever N/A N/A N/A 1007818CH 320 4 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening 1007801CH 320 4 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening 1007672CH 320 4 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub opening 1006344ACH 320 4 OH/UG Lever TBD TBD 5x5 hub opening 1004984ACH 320 4 OH/UG N/A #4–600 kcmil #4–600 kcmil 3-inch bolt-on hub 1004771BCH 200 7 OH/UG Lever 3/8-inch studs 3/8-inch studs N/A UBTH7230ACH 200 7 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub cover plate UTH7233UCH 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Notes 1 Bolted in shield. 5 5 5 For dimensions, see Pages V1-T5-16 and V1-T5-17. 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-13 5.2 Metering Products Commercial Lever Bypass Sockets 5 Commercial Lever Bypass, continued 5 Ampere Rating Jaws Service Bypass Line Load Opening, Hub or Closure Plate Catalog Number 200 7 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub cover plate UTE7213UFLCH 200 7 OH/UG Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub cover plate UETH72137UCH 200 7 OH/UG Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub cover plate UTE7213UCH 200 7 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub opening UTE7213THLCH 5 200 7 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub opening UBHRS212BCH 5 200 7 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub opening UBEH7213TCH 200 7 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub opening UFTE7213TCH 1 5 200 7 OH/UG Lever #6–350 kcmil #6–350 kcmil Large to small hub adapter UTE7213ZCH 200 7 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub opening UTE7213TCH 5 200 7 OH/UG Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub cover plate UTE7213CFLCH 5 200 7 OH/UG Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub cover plate UTE7213CCH 200 7 OH/UG Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub opening UBTE7213BCH 200 7 OH/UG Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub opening UTE7213BCH 200 7 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub cover plate UTE7210UCH UTE7203TCH 5 5 5 5 Connections 200 7 OH Lever #6–350 kcmil #6–350 kcmil 5x5 hub opening 200 7 OH Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub opening UTE7203BCH 200 5 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub cover plate UETH5213UCH 5 200 5 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub opening UTE5213TCH 200 5 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub opening UTTE5213TCH 5 200 5 OH/UG Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub cover plate UTE5213CCH 200 5 OH/UG Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub opening UTE5213BNDCH 5 200 5 OH/UG Lever #6–350 kcmil #6–350 kcmil Large to small hub adapter UTE5213ZCH 5 200 5 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub cover plate UTE5213UFLCH 200 5 OH/UG Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub cover plate UTE5213CFLCH 200 5 OH/UG Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub opening UTE5213BCH 200 5 OH/UG Lever 3/8-inch studs 3/8-inch studs 3-5/16 hub cover plate UTE5210CCH 5 200 5 OH Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub opening UTE5203BCH 5 200 4 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub opening with adapter plate UTE4213ZCH 200 5 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub cover plate UGTE4213CCH 200 4 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub opening UTE4213TCH 200 4 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub cover plate UTTE4213UCH 2 5 5 5 5 5 5 5 5 5 5 200 4 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub cover plate UTE4213CCH 200 4 OH/UG Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub opening UTE4213BCH 200 4 OH Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub opening UTE4203BCH 200 7 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub cover plate UIH7213UCVCH 200 7 OH/UG Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub cover plate UE7213CCCCH 200 7 OH/UG Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub cover plate UE7213CCPLCH 200 7 OH/UG Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub opening UE7213BCPLCH Notes 1 Barrel lock. 2 TT = quadplex ground. For dimensions, see Pages V1-T5-16 and V1-T5-17. 5 5 5 V1-T5-14 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Commercial Lever Bypass Sockets 5.2 Commercial Lever Bypass, continued Connections Ampere Rating Jaws Service Bypass Line 200 5 OH/UG Lever #6–350 kcmil 200 4 OH/UG Lever 200 7 OH/UG Lever 200 7 OH/UG 5 Load Opening, Hub or Closure Plate Catalog Number #6–350 kcmil 3-5/16 hub opening UGTE4213BCH #6–350 kcmil #6–350 kcmil 3-5/16 hub cover plate UGE4213CCCCH #6–350 kcmil #6–350 kcmil 3-5/16 hub opening UFTE7213BCH Lever #6–350 kcmil #6–350 kcmil 5x5 hub opening UATE7213TCH 200 5 OH/UG Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub cover plate UATE5213CCH 200 4 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub cover plate UATE4213UFLCH 200 5 OH Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub opening UBGTE4203BCH 200 7 UG Lever 4/0 compression line #6–350 kcmil cu/al load Solid top 1009845ECH 200 5 OH/UG Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub cover plate 1008801ECH 200 5 OH/UG Lever 3/8-inch studs 3/8-inch studs 3-5/16 hub cover plate 1008832ECH 200 4 UG Lever #6–350 kcmil #6–350 kcmil Solid top 1007944ECH 200 7 OH/UG Lever #6–350 kcmil cu/al #6–350 kcmil cu/al 5x5 hub opening 1007670ECH 200 7 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub opening UTTE7213TCH 5 5 5 5 5 5 5 5 Note For dimensions, see Pages V1-T5-16 and V1-T5-17. 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-15 5.2 5 Metering Products Commercial Lever Bypass Sockets Dimensions Approximate Dimensions in Inches (mm) 5 5 Commercial Lever Bypass Commercial Lever Bypass, continued Catalog Number Height Width Depth Catalog Number Height Width Depth UTTH7336TCH 39.89 (1013.2) 20.00 (508.0) 6.50 (165.1) UATH7336TCH 39.88 (1013.0) 20.00 (508.0) 6.50 (165.1) 5 UTH73069THLCH N/A N/A N/A UATH5330UFLCH 39.88 (1013.0) 20.00 (508.0) 6.50 (165.1) UTH73369UHLCH 39.89 (1013.2) 20.00 (508.0) 6.50 (165.1) UATH4336TCH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) 5 UTH73369THLCH 39.89 (1013.2) 20.00 (508.0) 6.50 (165.1) UATH4330TCH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) UFTH7330UCH 39.89 (1013.2) 20.00 (508.0) 6.50 (165.1) 1009788CH 34.50 (876.3) 13.00 (330.2) 4.94 (125.5) UTH7336TCH 39.89 (1013.2) 20.00 (508.0) 6.50 (165.1) 1009788ACH 2 34.50 (876.3) 13.00 (330.2) 4.94 (125.5) UTH7330UCH 39.89 (1013.2) 20.00 (508.0) 6.50 (165.1) 1009760ACH 36.63 (930.4) 15.00 (381.0) 5.68 (144.3) UTH7330UFLCH 39.89 (1013.2) 20.00 (508.0) 6.50 (165.1) 1009722CH 36.63 (930.4) 15.00 (381.0) 5.68 (144.3) 5 5 5 5 1 39.89 (1013.2) 20.00 (508.0) 6.50 (165.1) 782116975945 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) UH7330TCPLCH 39.89 (1013.2) 20.00 (508.0) 6.50 (165.1) 1009260CH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) 5 UTH7330TCH 39.89 (1013.2) 20.00 (508.0) 6.50 (165.1) 1009181CH 34.50 (876.3) 15.00 (381.0) 5.69 (144.5) 5 UTTH7330TCH 39.89 (1013.2) 20.00 (508.0) 6.50 (165.1) 1009018CH 63.00 (1600.2) 12.97 (329.4) 4.94 (125.5) UH7300UCPLCH 39.89 (1013.2) 20.00 (508.0) 6.50 (165.1) 1008950CH 39.88 (1013.0) 20.00 (508.0) 6.50 (165.1) UTH7300UCH 39.89 (1013.2) 20.00 (508.0) 6.50 (165.1) 1008948CH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) UTH7300TCH 34.50 (876.3) 15.00 (381.0) 5.63 (143.0) 1008848CH 58.00 (1473.2) 12.97 (329.4) 4.94 (125.5) 5 UTH5330UFLCH 39.88 (1013.0) 20.00 (508.0) 6.50 (165.1) 1008837CH 36.63 (930.4) 15.00 (381.0) 6.50 (165.1) 5 UTH5330UCH 39.88 (1013.0) 20.00 (508.0) 6.50 (165.1) 1008836CH 36.63 (930.4) 15.00 (381.0) 6.50 (165.1) UTH5300TCH 39.88 (1013.0) 20.00 (508.0) 6.50 (165.1) 1008798CH 34.50 (876.3) 15.00 (381.0) 5.69 (144.5) 5 UATH5330UFLCH 39.88 (1013.0) 20.00 (508.0) 6.50 (165.1) 1008793CH 34.50 (876.3) 13.00 (330.2) 4.94 (125.5) UTH4320ACH 26.00 (660.4) 15.00 (381.0) 5.68 (144.3) 1008792CH 34.50 (876.3) 13.00 (330.2) 4.94 (125.5) 5 UTH43209ACH N/A N/A N/A 1008543CH 39.89 (1013.2) 20.00 (508.0) 6.60 (167.6) 5 UTH4339UCH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) 1008541CH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) UTH4338UCH 29.00 (736.6) 15.00 (381.0) 5.69 (144.5) 1008540CH N/A N/A N/A 5 UTH4336UCH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) 1008435CH 26.00 (660.4) 15.00 (381.0) 5.69 (144.5) UTH4336TCH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) 1008191CH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) 5 UTH43369UCH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) 1008068CH 34.50 (876.3) 16.44 (417.6) 6.50 (165.1) UTH43369TCH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) 1007818CH N/A N/A N/A UTTH4330UCH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) 1007801CH 28.50 (723.9) 18.00 (457.2) 5.69 (144.5) 5 UTH4330UCH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) 1007672CH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) UBTH4330TCH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) 1006344ACH 28.50 (723.9) 18.00 (457.2) 5.69 (144.5) 5 UTH4330TCH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) 1004984ACH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) UTH4300UCH 34.50 (876.3) 13.00 (330.2) 4.94 (125.5) 1004771BCH 36.62 (930.1) 15.00 (381.0) 5.68 (144.3) 5 UTH4300TCH 34.50 (876.3) 13.00 (330.2) 4.94 (125.5) UBTH7230ACH N/A N/A N/A 5 UH5300UKCCH 34.50 (876.3) 13.00 (330.2) 4.94 (125.5) UTH7233UCH 27.00 (685.8) 16.00 (406.4) 5.63 (143.0) UH43168UCPLCH 34.50 (876.3) 15.00 (381.0) 5.69 (144.5) UH43068TCPLCH 34.50 (876.3) 13.00 (330.2) 4.94 (125.5) UGTH4330UCH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) Notes 1 Aluminum enclosure. 2 Bolted in shield. 5 UGTH4330TCH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) 5 UFTH7330TCH 39.88 (1013.0) 20.00 (508.0) 6.50 (165.1) UFTH4330TCH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) V1-T5-16 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 5 5 5 UATH7330UFLCH 5 5 5 5.2 Metering Products Commercial Lever Bypass Sockets Approximate Dimensions in Inches (mm) 5 Commercial Lever Bypass, continued 5 Commercial Lever Bypass, continued Catalog Number Height Width Depth Catalog Number Height Width Depth UTE7213UFLCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UGTE4213BCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UETH72137UCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UGE4213CCCCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTE7213UCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UFTE7213BCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTE7213THLCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UATE7213TCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UBHRS212BCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UATE5213CCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UBEH7213TCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UATE4213UFLCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UFTE7213TCH 1 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UBGTE4203BCH 19.00 (482.6) 10.50 (266.7) 4.94 (125.5) UTE7213ZCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) 1009845ECH 64.00 (1625.6) 11.00 (279.4) 6.00 (152.4) UTE7213TCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) 1008801ECH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTE7213CFLCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) 1008832ECH 24.69 (627.1) 13.00 (330.2) 4.94 (125.5) UTE7213CCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) 1007944ECH 22.00 (558.8) 16.00 (406.4) 5.69 (144.5) UBTE7213BCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) 1007670ECH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTE7213BCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTTE7213TCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTE7210UCH 24.69 (627.1) 13.00 (330.2) 4.94 (125.5) UTE7203TCH 19.00 (482.6) 10.50 (266.7) 4.94 (125.5) UTE7203BCH 19.00 (482.6) 10.50 (266.7) 4.94 (125.5) Notes 1 Barrel lock. 2 TT = quadplex ground. UETH5213UCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTE5213TCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTTE5213TCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTE5213CCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTE5213BNDCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTE5213ZCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTE5213UFLCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTE5213CFLCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTE5213BCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTE5210CCH 20.13 (511.3) 13.00 (330.2) 4.94 (125.5) UTE5203BCH 19.00 (482.6) 10.50 (266.7) 4.94 (125.5) UTE4213ZCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UGTE4213CCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTE4213TCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTTE4213UCH 2 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTE4213CCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTE4213BCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTE4203BCH 19.00 (482.6) 10.50 (266.7) 4.94 (125.5) UIH7213UCVCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UE7213CCCCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UE7213CCPLCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UE7213BCPLCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-17 5.3 5 Metering Products Multiple Position Horizontal Ganged Sockets Multiple Position Horizontal Ganged Sockets Contents Description 5 Catalog Number Selection . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 5 5 5 5 5 5 5 5 5 5 Product Description ● ● 5 ● 5 ● 5 ● 5 ● 5 Available in 100A and 200A designs Available in 2-position through 6-position designs Multiple service design offerings Multiple line/load lug configurations Residential or lever bypass socket designs Multiple hub opening and closure plate sizes available 5 5 5 5 5 5 5 5 5 5 5 5 V1-T5-18 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Page V1-T5-19 V1-T5-20 V1-T5-23 Metering Products Multiple Position Horizontal Ganged Sockets 5.3 Catalog Number Selection 5 5 Single Meter Sockets 2R-6R and 2H-6H Group 5 UT 2R 1 1 2 1 B CH Note: The “U” prefix is always used first followed by other prefixes required in alphabetical order. Standard Prefixes A = Aluminum enclosure B = Barrel lock provision, for an exposed INNER-TITE or Brooks barrel lock; unit includes an internal lock receiver bracket F = Barrel lock with guard provision, for a lock guard INNER-TITE or Brooks barrel lock; unit includes an internal lock receiver bracket G = Grounded fifth terminal (9 o’clock position) H = Horn bypass I = Inhibitor installed in wire connectors M = Temporary meter cover (waxed cardboard) N = No sealing ring (applies only to ring style sockets) R = Ring style socket S = Aluminum screw type sealing ring (applies only to ring style sockets) T = Grounding connector (#14–#2 Cu) for triplex ground TT = Two grounding connectors (#14–#2 Cu) for quadplex ground U = UL label Z = 5/16-inch hex head connector screw in place of slotted (100A only) RS = 2R-6R = 2H-6H = H = 5 Standard Suffixes Product Group Residential service, single position Residential service, multiple position Commercial or residential service, multiple position Commercial or residential service, single position Ampere Rating 1 = 100A 2 = 200A 5 A = Solid top B = Small hub opening C = Small hub closing plate mounted L = 1.25-inch (31.8 mm) hub mounted M = 1.50-inch (38.1 mm) hub mounted N = 2.00-inch (50.8 mm) hub mounted P = 2.50-inch (63.5 mm) hub mounted T = Large hub opening hub U = Large hub cover plate hub mounted V = 2.50-inch (63.5 mm) large hub mounted Q = 3.00-inch (76.2 mm) large hub mounted R = 3.50-inch (88.9 mm) large hub mounted S = 4.00-inch (101.6 mm) large hub mounted Z = Large to small hub adapter mounted 5 5 5 5 5 Maximum Load Conductor 0 = 0.38-inch stud connectors 1 = #2/0 connectors 2 = #250 kcmil connectors 3 = #350 kcmil connectors 5 = #500 kcmil connectors 6 = #600 kcmil connectors 7 = #750 kcmil connectors 8 = Dual #500 kcmil connectors 5 5 5 5 Maximum Line Conductor 0 = 0.38-inch stud connectors 1 = #2/0 connectors 2 = #250 kcmil connectors 3 = #350 kcmil connectors 5 = #500 kcmil connectors 6 = #600 kcmil connectors 7 = #750 kcmil connectors 8 = Dual #500 kcmil connectors 5 5 5 5 Service Design 5 0 = Overhead 1 = Combination overhead/underground 2 = Underground, side wired 3 = Combination overhead/underground, side wired 4 = End feed 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-19 5.3 5 5 5 Metering Products Multiple Position Horizontal Ganged Sockets Product Selection UT2R2332BCH Horizontal Design—Multi Position Ringless Connections Ampere Rating Jaws Position Service Bypass Line Load Opening, Hub or Closure Plate Catalog Number 200 4 2 OH/UG Horn #6–350 kcmil #8–250 kcmil 5x5 hub opening 1004401BCH 5 200 4 3 OH/UG Horn #6–350 kcmil #8–250 kcmil 5x5 hub opening 1004404BCH 200 5 2 OH/UG Horn #6–350 kcmil #8–250 kcmil 5x5 hub opening 1004418ACH 5 200 4 2 OH/UG — 3/8-inch stud #8–250 kcmil 5x5 hub cover plate 1006737BCH 5 200 4 2 OH/UG Horn 3/8-inch stud #8–250 kcmil 5x5 hub opening 1007700CH 200 4 3 OH/UG Horn 3/8-inch stud #8–250 kcmil Hub opening 1007701CH 5 200 4 2 OH/UG Horn #6–350 kcmil #8–250 kcmil 5x5 hub cover plate 1008842CH 200 4 3 OH/UG Horn 1/0–500 kcmil cu/al #8–250 kcmil 5x5 hub cover plate 1008843CH 5 200 4 4 OH/UG Horn 1/0–500 kcmil cu/al #8–250 kcmil 5x5 hub cover plate 1008844CH 200 4 2 OH/UG Horn #6–350 kcmil #8–250 kcmil 5x5 hub cover plate 1008958CH 200 4 3 OH/UG Horn 1/0–500 kcmil cu/al #8–250 kcmil 5x5 hub cover plate 1008959CH 5 200 4 4 OH/UG Horn 1/0–500 kcmil cu/al #8–250 kcmil 5x5 hub cover plate 1008960CH 200 4 5 OH/UG Horn (2) 1/0–500 kcmil cu/al #8–250 kcmil (2) 5x5 hub cover plate 1009579ACH 5 200 4 4 OH/UG Horn 1/0–500 kcmil cu/al 5x5 hub opening U4R2352TDQCH 200 4 5 OH/UG Horn (2) 1/0–500 kcmil cu/al #8–250 kcmil (2) 5x5 hub opening U5R2392TTDQCH 5 200 4 6 OH/UG Horn (2) 1/0–500 kcmil cu/al #8–250 kcmil 5x5 hub opening (2) places U6R2392TTDQCH 5 200 4 4 OH/UG Horn 1/0–500 kcmil cu/al #8–250 kcmil 5x5 hub opening UBH4R2352TCH 200 4 2 OH/UG Horn #6–350 kcmil #8–250 kcmil 5x5 hub opening UBH2R2332TCH 200 4 3 OH/UG Horn #6–350 kcmil #8–250 kcmil 5x5 hub opening UBH3R2332TCH 200 4 4 OH/UG Horn 3/8-inch stud #8–250 kcmil 5x5 hub cover plate UEHT4R2302UCH 5 200 4 3 OH/UG Horn 3/8-inch stud #8–250 kcmil 5x5 hub cover plate UEHT3R2302UCH 5 200 4 2 OH/UG Horn 3/8-inch stud #8–250 kcmil 5x5 hub cover plate UEHT2R2302UCH 200 4 2 UG Horn #6–350 kcmil #8–250 kcmil Solid top UHI2R2332ACVCH 5 5 5 #8–250 kcmil 5 200 4 2 OH/UG Horn #6–350 kcmil #8–250 kcmil Hub opening UHI2R2332TCVCH 200 4 4 UG Horn 1/0–500 kcmil cu/al #8–250 kcmil Solid top UHI4R2352ACVCH 5 200 4 2 OH/UG Horn #6–350 kcmil #8–250 kcmil 5x5 hub cover plate UHTT2R2332UCH 5 200 4 2 OH/UG Horn #6–350 kcmil #8–250 kcmil 5x5 hub opening UHT2R2332TCH 200 4 3 OH/UG Horn #6–350 kcmil #8–250 kcmil 5x5 hub opening UHT3R2332TCH 5 200 4 3 OH/UG Horn 1/0–500 kcmil cu/al #8–250 kcmil 5x5 hub cover plate UHT3R2352UCH 200 4 4 OH/UG Horn 1/0–500 kcmil cu/al #8–250 kcmil 5x5 hub opening UHT4R2352TCH 5 200 4 4 OH/UG — 1/0–500 kcmil cu/al #8–250 kcmil 5x5 hub cover plate UT4R2352UFLCH 200 4 4 OH/UG Horn 1/0–500 kcmil cu/al #8–250 kcmil 5x5 hub cover plate UHT4R2352UCH 200 5 2 OH/UG Lever 1/0–500 kcmil cu/al #6–350 kcmil 5x5 hub opening UT2H52353TCH 5 200 4 2 OH/UG Horn #6–350 kcmil #8–250 kcmil 5x5 hub cover plate UHT2R2332UCH 200 4 2 OH/UG — #6–350 kcmil #8–250 kcmil 3-5/16 hub opening UT2R2332BCH 5 200 4 2 OH/UG — #6–350 kcmil #8–250 kcmil 5x5 hub opening UAT2R2332TCH 1 200 4 2 OH/UG — #6–350 kcmil #8–250 kcmil 5x5 hub opening UT2R2332TCH 5 200 4 2 OH/UG — #6–350 kcmil #8–250 kcmil 5x5 hub opening U2R2332TCPLCH 5 200 4 2 OH/UG — #6–350 kcmil #8–250 kcmil 5x5 hub cover plate U2R2332UCPLCH 200 4 2 OH/UG Horn #6–350 kcmil #8–250 kcmil 5x5 hub opening U2R2332TDQCH 200 4 2 OH/UG — #6–350 kcmil #8–250 kcmil 5x5 hub cover plate UT2R2332UCH 200 4 3 OH/UG Horn #6–350 kcmil #8–250 kcmil Large 5X5 hub opening U3R2332TDQCH 5 5 5 Notes 1 Aluminum enclosure. 5 For dimensions, see Pages V1-T5-23 and V1-T5-24. V1-T5-20 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Multiple Position Horizontal Ganged Sockets UT2R1121BCH 5.3 Horizontal Design—Multi Position Ringless, continued Connections Ampere Rating Jaws Position Service Bypass Line 200 4 3 OH/UG Lever 1/0–500 kcmil cu/al 5 Load Opening, Hub or Closure Plate Catalog Number #6–350 kcmil 5x5 hub opening UT3H42353TCH 200 5 3 OH/UG Lever 1/0–500 kcmil cu/al #6–350 kcmil 5x5 hub opening UT3H52353TCH 200 7 3 OH/UG Lever 1/0–500 kcmil cu/al #6–350 kcmil 5x5 hub cover plate UT3H72353UHLCH 200 4 3 OH/UG — #6–350 kcmil #8–250 kcmil 5x5 hub opening UT3R2332TCH 200 4 3 OH/UG — #6–350 kcmil #8–250 kcmil 5x5 hub cover plate UT3R2332UCH 200 4 3 OH/UG — 1/0–500 kcmil cu/al #8–250 kcmil 5x5 hub opening UT3R2352TCH 200 4 4 OH/UG — 1/0–500 kcmil cu/al #8–250 kcmil 5x5 hub opening UT4R2352TCH 200 4 5 OH/UG Horn (2) 1/0–500 kcmil cu/al #8–250 kcmil 5x5 hub opening (in two places) UHT5R2392TTCH 200 4 5 OH/UG — (2) 1/0–500 kcmil cu/al #8–250 kcmil 5x5 hub opening (in two places) UT5R2392TTCH 200 7 5 OH/UG Lever Dual 1/0–500 kcmil (2) 5X5 hub closure plates UT5H72393UUHLCH 200 4 6 OH/UG Horn (2) 1/0–500 kcmil cu/al #8–250 kcmil #6–350 kcmil 5x5 hub opening (in two places) UHT6R2392TTCH 200 4 6 OH/UG — (2) 1/0–500 kcmil cu/al #8–250 kcmil 5x5 hub opening (in two places) UT6R2392TTCH 200 4 6 OH/UG — (2) 1/0–500 kcmil cu/al #8–250 kcmil 5x5 closure plate (in two places) UT6R2392UUFLCH 200 7 6 OH/UG Lever Dual 1/0–500 kcmil 5x5 closure plate (in two places) UT6H72393UUHLCH 200 4 6 OH/UG Horn (2) 1/0–500 kcmil cu/al #8–250 kcmil 5x5 hub opening (in two places) UHT6R2392TTCH 150 4 2 OH/UG Horn #6–350 kcmil #8–250 kcmil 3-5/16 hub opening U2R5432BDQCH 150 4 5 OH/UG — #6–350 kcmil #8–250 kcmil 3-5/16 hub opening (in two places) UT5R5632BCH 100 4 6 OH/UG — #6–350 kcmil #8–2/0 cu/al 3-5/16 hub opening UT6R1131BCH 100 4 2 OH/UG Horn #6–250 kcmil #8–2/0 cu/al 5x5 hub opening 1004426ACH 100 4 2 OH/UG Horn #6–250 kcmil #8–2/0 cu/al 3-5/16 hub opening 1008951CH 100 4 3 OH/UG Horn #6–250 kcmil #8–2/0 cu/al 3-5/16 hub opening 1008952CH 100 4 2 OH/UG Horn #6–250 kcmil #8–2/0 cu/al 3-5/16 hub cover plate 1009693CH 100 4 3 OH/UG Horn #6–250 kcmil #8–2/0 cu/al 3-5/16 hub cover plate 1009694CH 100 4 4 OH/UG Horn #6–250 kcmil #8–2/0 cu/al 3-5/16 hub cover plate 1009695CH 100 4 5 OH/UG Horn #6–250 kcmil #8–2/0 cu/al 3-5/16 hub cover plate 1009696CH 100 4 6 OH/UG — #6–350 kcmil #8–2/0 cu/al 3-5/16 hub cover plate UATZ6R1131CFLCH 1 100 4 2 OH/UG Horn #6–250 kcmil #8–2/0 cu/al 3-5/16 hub opening UBH2R1121BCH 100 4 3 OH/UG Horn #6–250 kcmil #8–2/0 cu/al 3-5/16 hub opening UBH3R1121BCH 100 4 4 OH/UG Horn #6–250 kcmil #8–2/0 cu/al 3-5/16 hub opening UBH4R1121BCH 100 4 2 OH/UG Horn #6–250 kcmil #8–2/0 cu/al 3-5/16 hub opening UHT2R1121BCH 100 4 4 OH/UG — #6–250 kcmil #8–2/0 cu/al 3-5/16 hub opening UT4R1121BCH 100 4 4 OH/UG — #6–250 kcmil #8–2/0 cu/al 3-5/16 closure plate UT4R1121CCH 100 4 4 OH/UG Horn #6–250 kcmil #8–2/0 cu/al 3-5/16 hub opening UHT4R1121BCH 100 4 5 OH/UG Horn #6–250 kcmil #8–2/0 cu/al 3-5/16 hub opening UHT5R1121BCH 100 4 5 OH/UG — #6–250 kcmil #8–2/0 cu/al 3-5/16 hub opening UT5R1121BCH 100 4 5 OH/UG — #6–250 kcmil #8–2/0 cu/al 3-5/16 closure plate UT5R1121CCH 100 4 2 OH/UG — #6–250 kcmil #8–2/0 cu/al 3-5/16 hub opening UT2R1121BCH 100 4 2 OH/UG — #6–250 kcmil #8–2/0 cu/al 3-5/16 closure plate UT2R1121CCH 100 4 2 OH/UG Horn #6–250 kcmil #8–2/0 cu/al 3-5/16 closure plate UHT2R1421CCH 100 4 2 OH/UG — #6–250 kcmil #8–2/0 cu/al 3-5/16 hub opening 3-5/16 hub cover plate UT2R1421BCH 100 4 3 OH/UG Horn #6–250 kcmil #8–2/0 cu/al 3-5/16 hub opening UHT3R1121BCH 100 4 3 OH/UG — #6–250 kcmil #8–2/0 cu/al 3-5/16 hub opening UT3R1121BCH #6–350 kcmil 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Notes 1 Aluminum enclosure. 5 For dimensions, see Pages V1-T5-23 and V1-T5-24. 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-21 5.3 Metering Products Multiple Position Horizontal Ganged Sockets 5 Horizontal Design—Multi Position Ring Type 5 Ampere Rating Jaws Position Service Bypass Line Load Opening, Hub or Closure Plate Catalog Number 5 200 4 2 OH/UG — 1/0–500 kcmil cu/al #8–250 kcmil 5x5 hub opening U2R2352TCRCH 200 4 2 OH/UG — #6–350 kcmil #8–250 kcmil 5x5 hub cover plate URT2R2332UCH 5 200 5 4 OH/UG — 1/0–500 kcmil cu/al #8–250 kcmil Large 5x5 hub opening U4R2352TCRCH 125 5 2 OH — #8–350 kcmil #8–2/0 cu/al Hub opening U2V1031BCRCH 1 5 125 5 3 OH — #8–350 kcmil #8–2/0 cu/al Hub opening U3V1031BCRCH 1 5 100 5 2 OH/UG — #6–250 kcmil #8–2/0 cu/al 3-5/16 opening U2R1121BCRCH 100 5 3 OH/UG — #6–250 kcmil #8–2/0 cu/al 3-5/16 opening U3R1121BCRCH 100 5 4 OH/UG — #6–250 kcmil #8–2/0 cu/al 3-5/16 opening U4R1121BCRCH 100 5 5 OH/UG — #6–250 kcmil #8–2/0 cu/al 3-5/16 opening U5R1121BCRCH 5 5 Connections Notes 1 Vertical gang. 5 For dimensions, see Pages V1-T5-23 and V1-T5-24. 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 V1-T5-22 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Multiple Position Horizontal Ganged Sockets 5.3 Dimensions 5 Approximate Dimensions in Inches (mm) 5 Horizontal Design—Multi Position Ringless Horizontal Design—Multi Position Ringless, continued Catalog Number Height Width Depth Catalog Number Height Width Depth 1004401BCH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) UT3R2332TCH 14.13 (358.9) 32.47 (824.7) 5.38 (136.7) 1004404BCH 14.13 (358.9) 32.47 (824.7) 5.38 (136.7) UT3R2332UCH 14.13 (358.9) 32.47 (824.7) 5.38 (136.7) 1004418ACH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) UT3R2352TCH 14.13 (358.9) 40.63 (1032.0) 5.38 (136.7) 1006737BCH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) UT4R2352TCH 14.13 (358.9) 40.63 (1032.0) 5.38 (136.7) 1007700CH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) UHT5R2392TTCH 14.13 (358.9) 54.78 (1391.4) 5.38 (136.7) 1007701CH 14.13 (358.9) 32.47 (824.7) 5.38 (136.7) UT5R2392TTCH 14.13 (358.9) 54.78 (1391.4) 5.38 (136.7) 1008842CH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) UT5H72393UUHLCH 29.56 (750.8) 72.15 (1832.6) 6.00 (152.4) 1008843CH 14.13 (358.9) 32.47 (824.7) 5.38 (136.7) UHT6R2392TTCH 14.13 (358.9) 62.94 (1598.7) 5.38 (136.7) 1008844CH 14.13 (358.9) 40.63 (1032.0) 5.38 (136.7) UT6R2392TTCH 14.13 (358.9) 62.94 (1598.7) 5.38 (136.7) 1008958CH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) UT6R2392UUFLCH 14.13 (358.9) 62.94 (1598.7) 5.38 (136.7) 1008959CH 14.13 (358.9) 32.47 (824.7) 5.38 (136.7) UT6H72393UUHLCH 23.56 (598.4) 83.28 (2115.3) 6.00 (152.4) 1008960CH 14.13 (358.9) 40.63 (1032.0) 5.38 (136.7) UHT6R2392TTCH 14.13 (358.9) 62.94 (1598.7) 5.38 (136.7) 1009579ACH 14.13 (358.9) 54.78 (1391.4) 5.38 (136.7) U2R5432BDQCH 14.13 (358.9) 20.16 (512.1) 5.38 (136.7) U4R2352TDQCH 14.13 (358.9) 40.63 (1032.0) 5.38 (136.7) UT5R5632BCH 14.13 (358.9) 48.63 (1235.2) 5.38 (136.7) U5R2392TTDQCH 14.13 (358.9) 62.94 (1598.7) 5.38 (136.7) UT6R1131BCH 14.13 (358.9) 56.93 (1446.0) 4.50 (114.3) U6R2392TTDQCH 14.13 (358.9) 62.94 (1598.7) 5.38 (136.7) 1004426ACH 14.13 (358.9) 24.31 (617.5) 4.50 (114.3) UBH4R2352TCH 14.13 (358.9) 40.63 (1032.0) 5.38 (136.7) 1008951CH 14.13 (358.9) 24.31 (617.5) 4.50 (114.3) UBH2R2332TCH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) 1008952CH 14.13 (358.9) 32.47 (824.7) 4.50 (114.3) UBH3R2332TCH 14.13 (358.9) 32.47 (824.7) 5.38 (136.7) 1009693CH 14.13 (358.9) 24.16 (613.7) 5.38 (136.7) UEHT4R2302UCH 14.13 (358.9) 40.63 (1032.0) 5.38 (136.7) 1009694CH 14.13 (358.9) 32.31 (820.7) 5.38 (136.7) UEHT3R2302UCH 14.13 (358.9) 32.47 (824.7) 5.38 (136.7) 1009695CH 14.13 (358.9) 49.94 (1268.5) 5.38 (136.7) UEHT2R2302UCH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) 1009696CH 14.13 (358.9) 48.63 (1235.2) 5.38 (136.7) UHI2R2332ACVCH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) UATZ6R1131CFLCH 14.13 (358.9) 56.94 (1446.3) 4.50 (114.3) UHI2R2332TCVCH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) UBH2R1121BCH 14.13 (358.9) 24.94 (633.5) 4.50 (114.3) UHI4R2352ACVCH 14.13 (358.9) 40.63 (1032.0) 5.38 (136.7) UBH3R1121BCH 14.13 (358.9) 32.47 (824.7) 4.50 (114.3) UHTT2R2332UCH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) UBH4R1121BCH 14.13 (358.9) 40.63 (1032.0) 4.50 (114.3) UHT2R2332TCH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) UHT2R1121BCH 14.13 (358.9) 24.31 (617.5) 4.50 (114.3) UHT3R2332TCH 14.13 (358.9) 32.94 (836.7) 5.38 (136.7) UT4R1121BCH 14.13 (358.9) 40.63 (1032.0) 4.50 (114.3) UHT3R2352UCH 14.13 (358.9) 32.47 (824.7) 5.38 (136.7) UT4R1121CCH 14.13 (358.9) 40.63 (1032.0) 4.50 (114.3) UHT4R2352TCH 14.13 (358.9) 40.63 (1032.0) 5.38 (136.7) UHT4R1121BCH 14.13 (358.9) 40.63 (1032.0) 4.50 (114.3) UT4R2352UFLCH 14.13 (358.9) 40.63 (1032.0) 5.38 (136.7) UHT5R1121BCH 14.13 (358.9) 48.78 (1239.0) 4.50 (114.3) UHT4R2352UCH 14.13 (358.9) 40.63 (1032.0) 5.38 (136.7) UT5R1121BCH 14.13 (358.9) 48.78 (1239.0) 4.50 (114.3) UT2H52353TCH 23.56 (598.4) 32.78 (832.6) 6.00 (152.4) UT5R1121CCH 14.13 (358.9) 48.78 (1239.0) 4.50 (114.3) UHT2R2332UCH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) UT2R1121BCH 14.13 (358.9) 24.31 (617.5) 4.50 (114.3) 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) UT2R1121CCH 14.13 (358.9) 24.31 (617.5) 4.50 (114.3) UT2R2332BCH 1 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) UHT2R1421CCH 14.13 (358.9) 20.16 (512.1) 5.38 (136.7) UT2R2332TCH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) UT2R1421BCH 14.13 (358.9) 20.16 (512.1) 5.38 (136.7) U2R2332TCPLCH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) UHT3R1121BCH 14.13 (358.9) 32.47 (824.7) 4.50 (114.3) U2R2332UCPLCH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) UT3R1121BCH 14.13 (358.9) 32.47 (824.7) 4.50 (114.3) U2R2332TDQCH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) UT2R2332UCH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) Note 1 Aluminum enclosure. U3R2332TDQCH 14.13 (358.9) 32.47 (824.7) 5.38 (136.7) UT3H42353TCH 23.56 (598.4) 43.91 (1115.3) 6.00 (152.4) UT3H52353TCH 23.56 (598.4) 43.91 (1115.3) 6.00 (152.4) UT3H72353UHLCH 23.56 (598.4) 43.91 (1115.3) 5.38 (136.7) UAT2R2332TCH Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 V1-T5-23 5.3 5 5 5 Metering Products Multiple Position Horizontal Ganged Sockets Approximate Dimensions in Inches (mm) Horizontal Design—Multi Position Ring Type Catalog Number Height Width Depth U2R2352TCRCH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) URT2R2332UCH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) 5 U4R2352TCRCH 14.13 (358.9) 48.00 (1219.2) 5.38 (136.7) U2V1031BCRCH 1 8.00 (203.2) 25.63 (650.9) 4.38 (111.1) 5 U3V1031BCRCH 1 8.00 (203.2) 35.88 (911.2) 4.38 (111.1) U2R1121BCRCH 14.13 (358.9) 28.00 (711.2) 4.50 (114.3) 5 U3R1121BCRCH 14.13 (358.9) 38.00 (965.2) 4.50 (114.3) 5 U4R1121BCRCH 14.13 (358.9) 48.00 (1219.2) 4.50 (114.3) U5R1121BCRCH 14.13 (358.9) 58.00 (1473.2) 4.50 (114.3) 5 5 Note 1 Vertical gang. 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 V1-T5-24 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Instrument Rated Sockets Instrument Rated Sockets 5.4 Contents Description Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page V1-T5-26 V1-T5-26 5 5 5 5 5 5 5 5 5 5 5 Product Description ● ● ● ● ● ● ● 5 Available in 6, 7, 8 and 13 terminal designs 20A ratings standard Multiple service designs available (overhead, underground, overhead/ underground) Multiple hub opening and closure plate sizes available 600 Vac rated Single cover/dual cover availability Provisional test switches and factory-installed test switch designs available 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-25 5.4 5 5 Metering Products Instrument Rated Sockets Product Selection USTS132CCH Instrument Rated Sockets Ampere Rating Jaws Service Opening, Hub or Closure Plate Catalog Number 20 13 terminal UG Solid top USTH131A123CH 5 20 13 terminal OH/UG 3-5/16 hub cover plate USTS131B102CH 5 20 13 terminal OH/UG 3-5/16 hub cover plate USTS132B101CH 20 13 terminal OH/UG 3-5/16 hub cover plate USTS132CCH 5 20 13 terminal OH/UG 1-inch bolt-on hub 1008694ACH 20 8 terminal OH/UG 1-inch bolt-on hub 1008695ACH 5 20 13 terminal N/A N/A 1007003BCH 20 13 terminal Solid top and bottom Solid top 1007003CCH 5 20 13 terminal OH/UG 3-5/16 hub cover plate USTL131C207CH 20 13 terminal OH/UG Hub opening USTS131BCH 5 20 13 terminal OH/UG 1-1/4-inch bolt-on hub USTS131L143CH 20 13 terminal N/A N/A USTS132BCH 20 6 terminal OH/UG Hub opening USTS61B138CH 5 5 5 20 6 terminal OH/UG Hub opening UST61BCH 20 8 terminal OH/UG Hub opening USTS82B166CH 20 8 terminal N/A Solid top and bottom 1007361BCH N/A N/A N/A N/A 1008539CH 5 20 13 terminal OH/UG 3-5/16 hub cover plate UASTS131C226CH 20 13 terminal OH 3-5/16 hub cover plate 1004671CH 5 20 7 terminal OH 3-5/16 hub cover plate ULTS131CCH 20 6 terminal UG Solid top STL61A433CH 20 13 terminal UG Solid top STL131A120CH 5 5 5 Dimensions 5 Approximate Dimensions in Inches (mm) 5 Instrument Rated Sockets Catalog Number Height Width Depth 5 USTH131A123CH 20.00 (304.8) 12.00 (304.8) 4.36 (110.7) USTS131B102CH 20.00 (304.8) 12.00 (304.8) 4.36 (110.7) 5 USTS132B101CH 20.00 (304.8) 12.00 (304.8) 4.36 (110.7) 5 USTS132CCH 20.00 (304.8) 12.00 (304.8) 4.36 (110.7) 1008694ACH 20.00 (304.8) 12.00 (304.8) 4.36 (110.7) 5 1008695ACH 20.00 (304.8) 12.00 (304.8) 4.36 (110.7) 1007003BCH N/A N/A N/A 5 1007003CCH 16.50 (419.1) 14.00 (355.6) 3.50 (88.9) USTL131207CH 20.00 (304.8) 12.00 (304.8) 4.35 (110.5) 5 USTS131BCH 20.00 (304.8) 12.00 (304.8) 4.35 (110.5) USTS131L143CH 20.00 (304.8) 12.00 (304.8) 4.35 (110.5) 5 USTS132BCH N/A N/A N/A 5 USTS61B138CH 20.00 (304.8) 12.00 (304.8) 4.35 (110.5) UST61BCH 20.00 (304.8) 12.00 (304.8) 4.35 (110.5) 5 USTS82B166CH 20.00 (304.8) 12.00 (304.8) 4.35 (110.5) 1007361BCH 16.50 (419.1) 14.00 (355.6) 3.50 (88.9) 5 1008539CH N/A N/A N/A UASTS131C226CH 20.00 (304.8) 12.00 (304.8) 4.35 (110.5) 5 1004671CH 17.00 (431.8) 10.00 (254.0) 5.00 (127.0) ULTS131CCH 22.00 (558.8) 12.00 (304.8) 4.94 (125.5) 5 V1-T5-26 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Residential Pedestals Residential Pedestals 5.5 Contents Description Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page V1-T5-28 V1-T5-28 5 5 5 5 5 5 5 5 5 5 5 Product Description ● ● ● ● ● 5 Available in 100A, 200A, 300A and 320A designs Available in 4- or 5-jaw configurations Underground service design is standard Bypass options (lever, horn) are available Solid top designs 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-27 5.5 5 5 Metering Products Residential Pedestals Product Selection UHTRP242363CH 5 5 Residential Pedestals Connections Ampere Rating Jaws Service Bypass Line Load Opening, Hub or Closure Plate Catalog Number Solid top 1008847CH 320 4 UG — 3/8-inch studs 3/8-inch studs 320 4 UG Lever #6–350 kcmil line and line neutral 2/0–250 kcmil load and load neutral Solid top 300 4 UG Lever #6–350 kcmil line and line neutral 2/0–250 kcmil load and load neutral Solid top 5 200 4 UG Horn 4/0 compression (line) 2/0 compression (neutral) #6–250 kcmil load and load neutral Solid top 1006388CH 5 200 4 UG Horn #8–350 kcmil #8–350 kcmil Solid top UHTRP242363CH 200 4 UG Horn #6–350 kcmil line and line neutral #6–250 kcmil load neutral Solid top 1008846CH 5 200 4 UG Horn #6–350 kcmil line and line neutral #6–250 kcmil load neutral N/A 1008961CH 5 200 5 N/A N/A N/A N/A N/A 1008966CH 200 4 UG — #6–350 kcmil line and line neutral #6–350 kcmil load and load neutral Solid top 1009264CH 5 200 4 UG — 4/0 compression (line) 2/0 compression (neutral) #6–350 kcmil load and load neutral Solid top 1009265CH 5 100 4 UG — #6–350 kcmil line and line neutral #6–250 kcmil load neutral 1009078CH 5 5 Pedestal Extension Kits 5 Connections Line Load Catalog Number 5 Pedestal extension kit for 1008846CH Pedestal extension kit for 1008846CH 1009021CH 1009022CH 5 5 1009026CH Dimensions 5 Approximate Dimensions in Inches (mm) 5 Residential Pedestals 5 Catalog Number Height Width Depth 1008847CH 58.00 (1473.2) 12.97 (329.4) 4.93 (125.2) 1009017CH 1 63.00 (1600.2) 12.96 (329.2) 4.93 (125.2) 1006388CH 61.00 (1549.4) 8.96 (227.6) 4.93 (125.2) UHTRP242363CH 62.63 (1590.8) 8.97 (227.8) 4.94 (125.5) 1008846CH 70.00 (1778.0) 11.00 (279.4) 6.00 (152.4) 5 1008961CH 69.93 (1776.2) N/A 6.00 (152.4) 5 1008966CH N/A N/A N/A 1009264CH 74.00 (1879.6) 8.96 (227.6) 4.93 (125.2) 1009265CH 74.00 (1879.6) 8.97 (227.8) 4.94 (125.5) 1009078CH 69.93 (1776.2) 11.00 (279.4) 6.00 (152.4) 5 5 5 5 5 5 5 5 Pedestal Extension Kits Catalog Number Height Width Depth 1009021CH 18.00 (457.2) 11.00 (279.4) 6.00 (152.4) 1009022CH 18.00 (457.2) 12.96 (329.2) 4.93 (125.2) 1009026CH 30.00 (762.0) 12.96 (329.2) 4.93 (125.2) Note 1 200A breakers. 5 V1-T5-28 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Solid top 1009017CH 1 Metering Products Accessories and Cross-Reference 5.6 Product Description 5 This section will help you better understand the features and benefits of the 125A and 200A Eaton designed meter socket. 5 5 5 Features and Benefits Construction Features 5 200A Ringless Block Assembly With Horn Bypass 5 5 5 1. High strength, glass-filled meter block assembly, lay-in connectors with captive slide nut and screw. 5 5 3. Extruded neutral lug with integral triplex ground and quadplex ground provision. 5 5 5 5 2. 100% plated copper alloy meter jaw with reinforcing spring clip and meter guide. 4. Bridge and meter supports are 100% zinc chromate plated. 5. Fifth terminal locating hole in 9 o’clock position. 9. Extra rigid meter support for ringless sockets. 6. Triplex ground is a standard feature. 10. Optional, integral horn bypass extruded on slide nut. Horn is ribbed for secure attachment to utility bypass jumpers. Field-installable horn bypass kit available. 7. Quadplex ground provision. 8. Durable “four-point” bridge mounting (2 top, 2 bottom). 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-29 5.6 5 5 Metering Products Accessories and Cross-Reference Product Selection Meter Socket Accessories 5 Description Part Number 5 Hub closure plate meter socket accessories ARP00002CHB Clam shell hub closure plate meter socket accessories ARP00002CHBCS 5 1-inch hub closure plate meter socket accessories ARP00003CH1 Clam shell 1-inch hub closure plate—small opening ARP00003CH1CS 5 1-1/4-inch hub closure plate meter socket accessories ARP00004CH12 Clam shell 1-1/4-inch hub closure plate—small opening ARP00004CH12CS 1-1/2-inch hub closure plate meter socket accessories ARP00005CH15 5 Clam shell 1-1/2-inch hub closure plate—small opening ARP00005CH15CS 2-inch hub closure plate meter socket accessories ARP00006CH2 5 2-1/2-inch hub for meter socket accessories ARP00007CH25 Clam shell 2-1/2-inch hub for meter socket accessories ARP00007CH25CS 5 Aluminum hub closure plate for single sockets ARP00008CH 5 Hub adapter from large opening to small opening ARP00015CHAP Large hub cover plate ARP00016CHB 2-inch hub with large diameter opening ARP00017CH2 2.5-inch hub with large diameter opening ARP00018CH25 5 3-inch hub ARP00019CH3 5 3-1/2-inch hub for meter sockets ARP00020CH35 4-inch hub ARP00021CH4 5 Screw sealing ring for single meter sockets ARP00027CH Fifth jaw kit ARP00035CHJ 5 #6–350 kcmil lug kit for single sockets—3/8-inch stud ARP00119CH 5 #4–600 kcmil connector for single position meter sockets ARP00129CH Fifth jaw for bolt on meter ARP00326CH 5 #6–350 kcmil double barrel lug kit ARP00427CH Neutral Insulating Kit ARP00759CH 5 100A meter socket horn cap assembly kit ARP00777CH Fifth jaw kit for 320A offset socket ARP00862CH HQ anti-inversion clip for single meter sockets ARP00984CH 5 Fifth jaw for Chicago and Wisconsin pedestal ARP01085CH 350 kcmil BNS cap assembly kit for meter sockets ARP01226CH 5 Right hand block assembly with Z Bar ARP01258CH Left hand block assembly with Z Bar ARP01414CH Meter pack trough closure plate kit ARP01565CH 2/0 connector kit for MBB and MBP socket breaker ARP01612CH 5 5 5 5 5 5 5 5 5 5 5 V1-T5-30 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Accessories and Cross-Reference 5.6 Cross-Reference 5 5 Meter Sockets 5 Manufacturer Eaton Milbank Description Part Number Part Number 125A, OH/UG, ringless, triplex ground, hub opening UTRS101BE U7487-RL-TG 125A, OH/UG, ringless, triplex ground, hub cover plate UTRS101CE U7487-XL-TG 125A, OH/UG, ringless, triplex ground, hub opening, horn bypass UHTRS101BE U7487-RL-TG-KK 125A, OH/UG, ringless, triplex ground, hub cover plate, horn bypass UHTRS101CE U7487-XL-TG-KK 125A, OH/UG, ringless, triplex ground, hub opening, fifth terminal UTRS101BCH + MSR5TK U7487-RL-TG-5T 125A, OH/UG, ringless, triplex ground, hub cover plate, fifth terminal UTRS101CE + MSR5TK U7487-XL-TG-5T 125A, OH/UG, ringless, triplex ground, hub opening, horn bypass, fifth terminal UHTRS101BCH + MSR5TK U7487-RL-TG-KK-5T 125A, OH/UG, ringless, triplex ground, hub cover plate, horn bypass, fifth terminal UGHTRS101CE + MSR5TK U7487-XL-TG-KK-5T 200A, OH, ringless, triplex ground, hub opening UTRS202BCH U7021-RL-TG 200A, OH, ringless, triplex ground, hub cover plate UTRS202CCH U7021-XL-TG 200A, OH, ringless, triplex ground, hub opening, horn bypass UHTRS202BCH U7021-RL-TG-KK 200A, OH, ringless, triplex ground, hub cover plate, horn bypass UHTRS202CCH U7021-RL-TG-KK 200A, OH, ringless, triplex ground, hub opening, fifth terminal UGTRS202BCH U7021-RL-TG-5T 200A, OH, ringless, triplex ground, hub cover plate, fifth terminal UGTRS202CCH U7021-XL-TG-5T 200A, OH, ringless, triplex ground, hub opening, horn bypass, fifth terminal UGHTRS202BCH U7021-RL-TG-KK-5T 200A, OH, ringless, triplex ground, hub cover plate, horn bypass, fifth terminal UGHTRS202CCH U7021-RL-TG-KK-5T 200A, OH/UG, ringless, triplex ground, hub opening, 250 kcmil lugs UTRS212BCH No cross (no 250 kcmil lugs) 200A, OH/UG, ringless, triplex ground, hub cover plate, 250 kcmil lugs UTRS212CCH No cross (no 250 kcmil lugs) 200A, OH/UG, ringless, triplex ground, hub opening, horn bypass, 250 kcmil lugs UHTRS212BCH No cross (no 250 kcmil lugs) 200A, OH/UG, ringless, triplex ground, hub cover plate, horn bypass, 250 kcmil lugs UHTRS212CCH No cross (no 250 kcmil lugs) 200A, OH/UG, ringless, triplex ground, hub opening, fifth terminal, 250 kcmil lugs UGTRS212BCH No cross (no 250 kcmil lugs) 200A, OH/UG, ringless, triplex ground, hub cover plate, fifth terminal, 250 kcmil lugs UGTRS212CCH No cross (no 250 kcmil lugs) 200A, OH/ UG, ringless, triplex ground, hub opening, horn bypass, fifth terminal, 250 kcmil lugs UGHTRS212BCH No cross (no 250 kcmil lugs) 200A, OH/UG, ringless, triplex ground, hub cover plate, horn bypass, fifth terminal, 250 kcmil lugs UGHTRS212CCH No cross (no 250 kcmil lugs) 200A, OH/UG, ringless, triplex ground, hub opening, 350 kcmil lugs UTRS213BE U7040-RL-TG 200A, OH/UG, ringless, triplex ground, hub cover plate, 350 kcmil lugs UTRS213CE U7040-XL-TG 200A, OH/UG, ringless, triplex ground, hub opening, horn bypass, 350 kcmil lugs UHTRS213BE U7040-RL-TG-KK 200A, OH/UG, ringless, triplex ground, hub cover plate, horn bypass, 350 kcmil lugs UHTRS213CE U7040-XL-TG-KK 200A, OH/UG, ringless, triplex ground, hub opening, fifth terminal, 350 kcmil lugs UGTRS213BE U7040-RL-TG-5T 200A, OH/UG, ringless, triplex ground, hub cover plate, fifth terminal, 350 kcmil lugs UGTRS213CE U7040-XL-TG-5T 200A, OH/ UG, ringless, triplex ground, hub opening, horn bypass, fifth terminal, 350 kcmil lugs UGHTRS213BE U7040-RL-TG-KK-5T 200A, OH/UG, ringless, triplex ground, hub cover plate, horn bypass, fifth terminal, 350 kcmil lugs UGHTRS213CE U7040-XL-TG-KK-5T 200A, UG, ringless, triplex ground, solid top UTRS223ACH U1980-0-TG 200A, UG, ringless, triplex ground, solid top, horn bypass UHTRS223ACH U1980-0-TG-KK 200A, UG, ringless, triplex ground, solid top, fifth terminal UGTRS223ACH U1980-O-TG-5T 200A, UG, ringless, triplex ground, solid top, horn bypass, fifth terminal UGHTRS223ACH U1980-O-TG-KK-5T 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-31 5.6 5 5 5 Metering Products Accessories and Cross-Reference Lever Bypass Manufacturer Eaton Milbank Description Part Number Part Number U9800-RL 200A, OH, lever bypass, 4 terminal, small hub opening UTE4203BCH 200A, OH, lever bypass, 4 terminal, hub cover plate UTH4203CCH U9800-XL 200A, OH, lever bypass, 4 terminal, large hub opening UTH4203TCH U9800-R 5 200A, OH, lever bypass, 4 terminal, large hub cover plate UTH4203UCH U9800-X 5 200A, OH, lever bypass, 5 terminal, small hub opening UTE5203BCH U4550-RL 200A, OH, lever bypass, 5 terminal, hub cover plate UTH5203CCH U4550-XL 200A, OH, lever bypass, 5 terminal, large hub opening UTH5203TCH U9559-R 200A, OH, lever bypass, 5 terminal, large hub cover plate UTH5203UCH U9550-X 5 5 5 5 200A, OH, lever bypass, 7 terminal, small hub opening UTE7203BCH U4701-RL 200A, OH, lever bypass, 7 terminal, hub cover plate UTH7203CCH U4701-XL 200A, OH, lever bypass, 7 terminal, large hub opening UTE7203TCH U4701-R 5 200A, OH, lever bypass, 7 terminal, large hub cover plate UTH7203UCH U4701-X 200A, OH/UG, lever bypass, 4 terminal, small hub opening UTE4213BCH U9801-RL 5 200A, OH/UG, lever bypass, 4 terminal, hub cover plate UTE4213CCH U9801-XL 200A, OH/UG, lever bypass, 4 terminal, large hub opening UTE4213TCH U9801-R 5 200A, OH/UG, lever bypass, 4 terminal, large hub cover plate UTH4213UCH U9801-XL 5 200A, OH/UG, lever bypass, 4 terminal, large hub opening with adapter plate UTE4213ZCH U9801-RRL 200A, OH/UG, lever bypass, 4 terminal, large hub opening with adapter and cover plate UTH4213YCH U9801-RXL 5 200A, OH/UG, lever bypass, 5 terminal, small hub opening UTE5213BCH U4551-RL U4551-XL 200A, OH/UG, lever bypass, 5 terminal, hub cover plate UTE5213CCH 200A, OH/UG, lever bypass, 5 terminal, large hub opening UTE5213TCH U9551-R 200A, OH/UG, lever bypass, 5 terminal, large hub cover plate UTH5213UCH U9551-X 200A, OH/UG, lever bypass, 5 terminal, large hub opening with adapter plate UTE5213ZCH U9551-RRL or U4551-RRL 5 200A, OH/UG, lever bypass, 5 terminal, large hub opening with adapter and cover plate UTH5213YCH U9551-RXL or U4551-RXL 200A, OH/UG, lever bypass, 7 terminal, small hub opening UTE7213BCH U9701-RL or U4701-RL 5 200A, OH/UG, lever bypass, 7 terminal, hub cover plate UTE7213CCH U9701-XL or U4701-XL 5 200A, OH/UG, lever bypass, 7 terminal, large hub opening UTE7213TCH U9701-R or U4701-R 200A, OH/UG, lever bypass, 7 terminal, large hub cover plate UTE7213UCH U9701-RX or U4701-RX 5 5 5 200A, OH/UG, lever bypass, 7 terminal, large hub opening with adapter plate UTE7213ZCH U9701-RRL or U4701-RRL 200A, OH/UG, lever bypass, 7 terminal, large hub opening with adapter and cover plate UTH7213YCH U9701-RXL or U4701-RXL 5 320A, OH, lever bypass, 4 terminal, large hub opening UTH4300TCH U1079-R or U1797-R 320A, OH, lever bypass, 4 terminal, large hub cover plate UTH4300UCH U1079-X or U1797X 5 320A, OH/UG, lever bypass, 4 terminal, large hub opening UTH4330TCH U2448-R or U2124-R 5 320A, OH/UG, lever bypass, 4 terminal, large hub cover plate UTH4330UCH U2448-RX or U2124-RX 320A, OH, lever bypass, 7 terminal, large hub opening UTH7300TCH — 5 320A, OH, lever bypass, 7 terminal, large hub cover plate UTH7300UCH — 320A, OH/UG, lever bypass, 7 terminal, large hub opening UTH7330TCH U2120-R 320A, OH/UG, lever bypass, 7 terminal, large hub cover plate UTH7330UCH U2120-X 5 5 5 5 5 5 V1-T5-32 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Accessories and Cross-Reference 5.6 Accessories 5 Manufacturer Eaton Milbank Description Part Number Part Number Small hub cover plate ARP00002CHB A7551 1-inch hub ARP00003CH1 A7514 1-1/4-inch hub ARP00004CH12 A7515 1-1/2-inch hub ARP00005CH15 A7516 2-inch hub ARP00006CH2 A7517 2-1/2-inch hub ARP00007CH25 A7518 3-inch hub ARP00019CH3 A8110 3-1/2-inch hub ARP00020CH35 A8111 4-inch hub ARP00021CH4 A8112 Large to small hub opening adapter plate ARP00015CHAP S8324 Large hub cover plate ARP00016CHB S9064 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-33 5.7 5 Metering Products Mechanical Lugs Contents Mechanical Lugs Description 5 Mechanical Lugs 5 5 5 5 5 5 5 5 5 5 5 5 5 Product Description ● ● ● Single lug Extended tang single lug Extended tang triple lug ● ● ● Double lug Extended tang double lug Extended tang quadruple lug Product Selection Dimensions Approximate Dimensions in Inches (mm) 5 Mechanical Lugs 5 Description Style Number Style Number Height Single #14–#6 mechanical lug ESL146 ESL146 2.50 (63.5) 8.25 (82.6) 3.50 (88.9) Single #14–2/0 mechanical lug ESL1420 ESL1420 2.50 (63.5) 10.50 (266.7) 3.50 (88.9) Single #6–250 kcmil mechanical lug ESL6250 ESL6250 2.50 (63.5) 10.50 (266.7) 3.50 (88.9) 5 Single #4–500 kcmil mechanical lug ESL4500 ESL4500 2.50 (63.5) 10.50 (266.7) 3.50 (88.9) 5 Double #14–2/0 mechanical lug EDL1420 EDL1420 3.50 (88.9) 4.00 (101.6) 3.50 (88.9) Double #6–250 kcmil mechanical lug EDL6250 EDL6250 3.50 (88.9) 3.75 (95.3) 4.50 (114.3) 5 Extended tang single lug #6–350 kcmil EPBSL6350 EPBSL6350 2.50 (63.5) 8.25 (82.6) 3.50 (88.9) Extended tang single lug 300–800 kcmil EPBSL300800 EPBSL300800 2.50 (63.5) 10.50 (266.7) 3.50 (88.9) 5 Extended tang double lug #6–350 kcmil EPBDL6350 EPBDL6350 3.50 (88.9) 4.50 (114.3) 5.50 (139.7) 5 Extended tang double lug 300–800 kcmil EPBDL300800 EPBDL300800 3.00 (76.2) 10.50 (266.7) 5.50 (139.7) Extended tang triple lug #6–350 kcmil EPBTL6350 EPBTL6350 3.50 (88.9) 4.50 (114.3) 5.50 (139.7) 5 Extended tang triple lug 300–800 kcmil EPBTL300800 EPBTL300800 2.50 (63.5) 10.00 (254.0) 5.75 (146.0) Extended tang quadruple lug #6–350 kcmil EPBQL6350 EPBQL6350 2.25 (57.2) 6.50 (165.1) 6.00 (152.4) 5 Extended tang quadruple lug 300–750 kcmil EPBQL300800 EPBQL300800 4.25 (108.0) 8.50 (215.9) 8.50 (215.9) Extended tang single lug #2–600 kcmil EPBSL2600 EPBSL2600 2.50 (63.5) 8.25 (82.6) 3.50 (88.9) Extended tang single lug 500–1000 kcmil EPBSL5001000 EPBSL5001000 2.50 (63.5) 10.50 (266.7) 3.50 (88.9) Extended tang triple lug #2–600 kcmil EPBTL2600 EPBTL2600 2.25 (57.2) 6.50 (165.1) 6.00 (152.4) 5 5 5 Mechanical Lugs 5 5 5 V1-T5-34 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Width Length Metering Products Communications Grounding Device (NEC 250.94) 5.8 Contents Communication Grounding Device Description Page Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-36 V1-T5-36 5 5 5 5 5 5 5 5 5 5 Product Description This product is required per the 2008 NEC Article 250.94 “Bonding for Other Systems.” This product is applied externally to residential homes, so that communications systems devices such as satellite, TV, cable and CATV can be properly bonded at a single point. This device has two mounting holes that can be used for easy installation. Features, Benefits and Functions Product Selection Communication Grounding Device Features ● Lay-in lug for ease of installation ● Four bonding terminals ● Heavy-duty zinc-plated steel screws included ● Two mounting holes to securely hold device into place ● For use with copper and aluminum conductors Communication Grounding Device 5 5 5 Wire Range Bonding Conductor Ground Electrode Quantity Catalog Number 5 #14–#2–STR–SOL–CU #12–#2–SRT–SOL–AL #8–1/0–STR–SOL–CU/AL (1) Clamshell MSEGR2CS 5 #14–#2–STR–SOL–CU #12–#2–SRT–SOL–AL #8–1/0–STR–SOL–CU/AL (10) Bulk pack MSEGR2 5 5 5 Cover Features ● Outdoor rated reinforced glass polyester compound ● Suitable for UV exposure ● Paintable exterior, allowing for matching of exterior of home 5 Standards and Certifications 5 ● 5 5 5 5 ETL listed 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-35 5.8 5 5 Metering Products Communications Grounding Device (NEC 250.94) Wiring Diagram Installation and Configuration 5 5 Service Entrance Panel 5 Single Meter Socket 5 5 5 5 Communication Grounding Device (Top View) 5 5 Grounding Electrode Conductor 5 5 5 5 5 5 5 5 Phone System Ground Grounding Electrode Conductor Communication Grounding Device (Top view) 5 Mounting Holes (Typical) 5 5 Satellite TV Ground 5 5 5 5 5 5 5 Coax Cable Ground Dimensions Approximate Dimensions in Inches (mm) Communication Grounding Device Catalog Number Length Width Height MSEGR2CS 0.75 (19.1) 3.90 (99.1) 1.20 (30.5) MSEGR2 0.75 (19.1) 3.90 (99.1) 1.20 (30.5) 5 V1-T5-36 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Meter Breakers 5.9 Contents Residential Meter Breakers Description Page Residential Meter Breakers Non-EUSERC Combination Service Entrance Devices 100–200A Styles . . . . . . . . . . . . . . . . . . Meets EUSERC Requirements Service Entrance Devices 100–225A . . . . . . . . . . . . . . . . . . . . . . . West Coast All-In-One Design. . . . . . . . . . . . . . . . Mechanical Interlock Cover . . . . . . . . . . . . . . . . . . House Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . Commercial Safety Sockets. . . . . . . . . . . . . . . . . . CH Style Renovation Solutions . . . . . . . . . . . . . . . Aluminum Meter Breakers . . . . . . . . . . . . . . . . . . V1-T5-39 V1-T5-48 V1-T5-59 V1-T5-65 V1-T5-75 V1-T5-83 V1-T5-86 V1-T5-87 5 5 5 5 5 5 5 5 5 5 5 Residential Meter Breakers Product Description Application Description A meter breaker is service entrance equipment that consists of a single meter socket and loadcenter (circuit breaker distribution section) or meter socket and main breaker combined in one enclosure. Sometimes called Combos, All-in-Ones, Meter Centers or Meter Mains, these units are increasing in popularity as the socket and loadcenter or main breaker are located in one location, thus providing the contractor with a labor and material savings when installing. In addition to residential installations, meter breakers are equally applicable for rural service entrance, mobile homes and construction site temporary power. Meter breakers are most often sold in the western, southwestern and southeastern United States. The popularity of meter breakers is continuing to increase as more utilities deregulate and pass the responsibility of supplying watthour meter sockets on to the electrical contractor. EUSERC/West Coast (Page V1-T5-59) Application Considerations Eaton has the meter breaker to meet your application, offering: CH and BR Styles (Page V1-T5-76). ● ● ● ● Non-EUSERC EUSERC/West Coast House panels Commercial safety socket Non-EUSERC (Page V1-T5-39) Eaton’s line of non-EUSERC meter breakers are designed for customers served by utilities that are not members of EUSERC. Eaton’s line of EUSERC required devices adhere to the agreed upon standards. EUSERC utilities are predominately located in the western United States, but some eastern and midwestern utilities are also members. These units can also be used in many Non-EUSERC areas. House Panels (Page V1-T5-75) Meter breaker device rated at 300–400A. Applied in EUSERC and non-EUSERC areas. Commercial Safety Sockets (Page V1-T5-83) ● ● ● ● ● ● ● ● ● ● Applied in EUSERC and non-EUSERC service areas and used in commercial applications. 5 Features, Benefits and Functions ● ● ● Both Type BR and CH branch circuit breaker styles available Meets latest NEC wire bending space requirements Slotted sealing screws at hub with sealing provision provided Surface units are supplied with mounting tabs Semi-flush units are supplied with stucco flange Meter socket ring landing will accept locking security rings Overhead or underground service Fifth jaw can be installed in the 3 o’clock or 9 o’clock position Semi-flush with nail flange or surface mounting Meter mounting and underground pull sections are utility sealable Units are rated a minimum of 10 kAIC; some units are 22 kAIC Numerous units supplied with center keyhole for ease of mounting NEMA 3R rainproof construction 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-37 5.9 5 5 Meter Breakers Standards and Certifications ● ● 5 ● 5 ● 5 ● 5 Metering Products ● UL Specification 414 (socket) UL File Number E52977 AEIC-EEI-NEMA Standards (MSJ-7) Meet EUSERC utility requirements where noted Documented seismic qualified—UBC® and CBC Title 24 UL Specification 67 (panel) Technical Data and Specifications ● ● ● ● Ratings single-phase, three-wire, 120/240 Vac 100–225A main breaker and main lug types 10,000A rms symmetrical short-circuit rating Available kAIC ratings: 10k with BW breaker, 22k with CSR breaker and 35k with CSH breaker Consult TD.31F.01.T.E for dimensions, wiring diagrams and knockouts. 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 V1-T5-38 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Meter Breakers 5.9 Contents Residential Meter Breakers Description Page Residential Meter Breakers. . . . . . . . . . . . . . . . . . Non-EUSERC Combination Service Entrance Devices 100–200A Styles Meets EUSERC Requirements Service Entrance Devices 100–225A . . . . . . . . . . . . . . . . . . . . . . . West Coast All-In-One Design. . . . . . . . . . . . . . . . Mechanical Interlock Cover . . . . . . . . . . . . . . . . . . House Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . Commercial Safety Sockets . . . . . . . . . . . . . . . . . CH Style Renovation Solutions . . . . . . . . . . . . . . . Aluminum Meter Breakers . . . . . . . . . . . . . . . . . . V1-T5-37 5 5 5 V1-T5-48 V1-T5-59 V1-T5-65 V1-T5-75 V1-T5-83 V1-T5-86 V1-T5-87 5 5 5 5 5 Standard Design Non-EUSERC Panel 5 Compact Design 5 5 Non-EUSERC Combination Service Entrance Devices 100–200A Styles Product Description Application Description A device that may include a meter socket, main breaker and loadcenter section within the same enclosure. Eaton’s line of non-EUSERC meter breakers are designed for customers served by utilities that are not members of EUSERC. ● ● Meter main = meter socket and main breaker Meter breaker = meter socket, main breaker and loadcenter section 5 Features, Benefits and Functions Meter Mains and All-in-Ones ● Single-phase, three-wire, 120/240 Vac,10 kAIC ● Larger lay-in lugs and 3-inch (76.2 mm) knockouts for ease of installation ● Box-type main lugs included ● Factory-installed neutral ● Hub provisions on top endwall. If hubs are required, order “DS” style ● Ring, ringless and ringless with horn bypass styles available ● Ringless style, provided with embossed covers and security latch for utility company lock ● Padlockable device covers provide additional measure of safety and help prevent tampering ● NEMA 3R rainproof construction Meter Mains ● Meter socket and main breaker ● Stainless steel latches on meter compartments in MBP types ● No distribution section included All-in-Ones ● Meter socket and loadcenter distribution section ● Stainless steel latches on meter compartments ● Several designs with horn bypass and fifth jaw ● Center-fed main breaker, lugs or provision ● Uses Type BR 1-inch (25.4 mm) wide branch breakers ● Special channel for top exit 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-39 5.9 5 Metering Products Meter Breakers Catalog Number Selection MB 20 40 B 200 BT S 5 5 MB MBE CMB CMBE 5 5 Meter Breaker Type = 1-inch BR Type = 1-inch BR Type—EUSERC = 3/4-Inch (19.1 mm) CH Type = 3/4-inch (19.1 mm) CH Type— EUSERC Spacing Number of spaces Poles Maximum number of poles Main B = Main breaker included P = Provision for main L = Main lug 5 5 Amperes Amperage of unit 5 D CU C CR Accessories/Modifications = 5th jaw and horn bypass = Copper = Single cover compact design = Two cover compact design Mounting S = Surface F = Flush/stucco Breaker Feed BT = Bottom and top B = Bottom only T = Top only 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 V1-T5-40 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Meter Breakers 5.9 Product Selection 5 Note: See knockout drawings on Pages V1-T5-68 through V1-T5-74 for hub information. Standard Design Non-EUSERC Panel 5 Combination Service Entrance Devices—Non-EUSERC Ampere Rating Bypass Service kAIC Jaws Distribution Main Branch Breaker Type Page Numbers Dimensions Catalog and Enclosure Wiring Knockout 1 Number Shape 1 5 5 5 Ring Style Meter Mains (no distribution section included) Compact Design 150 None OH/UG 10 4 None CSH2150 None 13 V1-T5-46 V1-T5-74 MBB150BTSCR 150 None OH/UG 22 4 None CSH2150 None 3 V1-T5-43 V1-T5-70 CMBB150BTS 67 200 None OH/UG 10 4 None CSH2200 None 13 V1-T5-46 V1-T5-74 MBB200BTSCR 200 None OH/UG 2 4 None Provision 45 None 3 V1-T5-43 V1-T5-70 CMBP200BTS 67 200 None OH/UG 22 4 None CSH2200 None 3 — V1-T5-70 CMBB200BTS 67 CSH2150 None 13 V1-T5-46 V1-T5-74 MBB150BTSC 7 Ringless Meter Mains (no distribution section included) 150 None OH/UG 10 4 None 8 200 None OH/UG 10 4 None CSH2200 None 9 V1-T5-47 V1-T5-74 MBB200BTS 200 None OH/UG 10 4 None CSH2200 None 13 V1-T5-46 V1-T5-74 MBB200BTSC 7 150 None OH/UG 10 4 None CSH2125 None 9 V1-T5-47 V1-T5-74 MBB150BTS 200 None OH/UG 2 4 None Provision 3 None 9 V1-T5-47 V1-T5-74 MBP200BTS 7 200 Horn OH/UG 2 5 None Provision 34 None 11 V1-T5-45 V1-T5-74 MBP200SD 200 Horn OH/UG 2 5 None Provision 34 None 9 V1-T5-47 V1-T5-74 MBP200BTSD 100 Horn OH/UG 10 5 None Provision None 15 — V1-T5-74 CHMMB100BTS 150 Horn OH/UG 10 5 None CSR2150 None 16 — V1-T5-74 CHMMB150BTS 200 Horn OH/UG 10 5 None CSR2200 None 16 — V1-T5-74 CHMMB200BTS 150 None OH/UG 10 4 4/8 CSR BR — — — MB48B150TSG 200 None OH/UG 10 4 4/8 CSR BR — — — MB48B200BTSG 200 Lever OH/UG 22 4 8/16 CSR BR — — — MBX816B200BTS 200 Lever OH/UG 22 4 20/40 CSR BR — — — MBX2040B200BTS Notes 1 See Page V1-T5-68 for box details. 2 Per installed main breaker rating. 3 When a provision for main is provided, order one of the main breakers listed in Page V1-T5-43. Panels are dual labeled to accept Types BW, CSR or CSH Main Breakers. 4 MCBK225 lug kit is needed for load side cable connection for Meter Mains. Please order separately. 5 When a provision for main is provided, order one of the main breakers listed in this table. Panels are labeled to accept Type CSR Main Breakers. 6 Copper bus. 7 One-piece cover on utility side, Florida approved. 8 Single cover design. 9 Xcel approved. 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-41 5.9 5 5 5 5 Metering Products Meter Breakers Note: See knockout drawings on Pages V1-T5-68 through V1-T5-74 for hub information. Combination Service Entrance Devices—Non-EUSERC, continued Ampere Rating Bypass Service kAIC Jaws Distribution Main Branch Breaker Type Dimensions and Enclosure Shape 1 Page Numbers Wiring Knockout 1 Catalog Number CH 2 V1-T5-43 V1-T5-70 CMB24L125BTS 56 CH 3 V1-T5-44 V1-T5-70 CMB88B150BTS 56 Ring Style All-in-Ones (includes distribution section) 125 None OH/UG 2 4 2/4 150 None OH/UG 22 4 8 200 None OH/UG 10 4 4/8 CSR2200 BR 3 V1-T5-44 V1-T5-70 MB48B200BTS 67 5 200 None OH/UG 22 4 8 CSH2200 CH 3 V1-T5-44 V1-T5-70 CMB88B200BTS 567 200 None UG 22 4 32/42 CSH2200 CH 7 V1-T5-43 V1-T5-69 CMB3242B200BS 56 5 200 None OH/UG 22 — 42/42 — CH — — — CMB4242B200BTS 5 5 5 5 None—refer to Distribution CSH2150 Ringless All-in-Ones (includes distribution section) 125 None OH/UG 22 4 4/8 CSR2125 BR 21 — V1-T5-73 MBT48B125BTS 150 None OH/UG 22 4 4/8 CSR2150 BR 21 V1-T5-46 V1-T5-73 MBT48B150BTS 150 Horn OH/UG 10 5 8/16 BW2150 BR 11 — — MB816B150STD 8 5 150 Horn OH/UG 10 5 20/40 BW2150 BR 11 V1-T5-47 V1-T5-74 MB2040B150SD 8 200 None OH/UG 10 4 8/16 CSR2200 BR 10 V1-T5-46 V1-T5-74 MB816B200BTS 67 5 200 None OH/UG 10 4 8/16 CSR2200 BR 10 V1-T5-46 V1-T5-74 MB816B200BTSCU 567 200 Horn OH/UG 10 5 8/16 BW2200 BR 11 — — MB816B200STD 8 5 200 None OH/UG 2 4 8/16 Provision 4 BR 10 V1-T5-46 V1-T5-74 MB816P200BTS 67 None OH/UG 2 5 200 4 8/16 Provision 4 BR 10 V1-T5-46 V1-T5-74 MB816P200BTSCU 567 200 Horn OH/UG 2 5 8/16 Provision 4 BR 11 V1-T5-46 V1-T5-74 MB816P200STD 78 200 Horn OH/UG 2 5 8/16 Provision 4 BR 10 V1-T5-46 V1-T5-74 MB816P200BTSD 7 200 None OH/UG 10 4 12/12 CSH2200 CH 10 V1-T5-44 V1-T5-70 CMB1212B200BTS 567 OH/UG 2 4 6–2 Pole Main lugs CH 9 V1-T5-45 V1-T5-71 CMB1212L200BTS 57 OH/UG 2 4 12/12 Provision CH 10 V1-T5-45 V1-T5-71 CMB1212P200BTS 567 4 6–2 Pole Main lugs BR 9 V1-T5-44 V1-T5-71 MB1212L200BTS 7 CMB2424B200BTS 56 5 5 5 200 200 None None 4 5 200 None OH/UG 2 5 200 None OH/UG 22 4 24/24 CSH2200 CH 10 V1-T5-44 V1-T5-74 200 None OH/UG 22 4 24/36 CSH2200 CH 10 V1-T5-45 V1-T5-74 CMB2436B200BTS 5 5 200 None OH/UG 10 4 20/40 CSR2200 BR 10 V1-T5-47 V1-T5-74 MB2040B200BTS 6 200 None OH/UG 2 4 20/40 Provision 4 BR 10 V1-T5-47 V1-T5-74 MB2040P200BTS 6 5 20/40 Provision 4 BR 11 V1-T5-47 V1-T5-74 MB2040P200SD 8 5 200 Horn OH/UG 2 5 200 Horn OH/UG 10 5 20/40 CSR2200 BR 10 V1-T5-47 V1-T5-74 MB2040B200SD 8 200 Lever OH/UG 10 5 None CSH2200 None 14 V1-T5-45 V1-T5-73 CMBXB200BTS 5 5 200 Lever OH/UG 10 5 12/12 CSH2200 CH 14 V1-T5-45 V1-T5-73 CMBX1212B200BTS 57 200 Lever OH/UG 10 5 32/42 CSH2200 CH 14 V1-T5-46 V1-T5-73 CMBX3242B200BTS 5 5 200 Lever OH/UG 10 5 None Provision None 14 V1-T5-45 V1-T5-73 CMBXP200BTS 5 200 Lever OH/UG 10 5 12/12 Provision CH 14 V1-T5-45 V1-T5-73 CMBX1212P200BTS 57 5 200 Lever OH/UG 10 5 32/42 Provision CH 14 V1-T5-46 V1-T5-73 CMBX3242P200BTS 5 5 200 None OH/UG 2 4 4/8 Provision BR 21 V1-T5-46 V1-T5-73 MBT48P200BTS 7 200 None OH/UG 22 4 4/8 CSR2200 BR 21 V1-T5-46 V1-T5-73 MBT48B200BTS 7 5 5 5 5 Notes 1 See Page V1-T5-68 for box details. 2 Per installed main breaker rating. 3 Will accept maximum four single-pole, two-pole, or two quad breakers. 4 When a provision for main is provided, order one of the main breakers listed on Page V1-T5-43. All panels are dual labeled to accept Types BW, CSR, CSH Main Breakers. 5 Copper bus. 6 One-piece cover on utility side, Florida approved. 7 Units come with feed-through lugs. 8 Xcel approved. 5 V1-T5-42 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Meter Breakers 5.9 Main Breaker Selection Chart 5 Maximum Ampere Rating Two-Pole Breaker Catalog Numbers 10 kAIC 25 kAIC 25 kAIC 35 kAIC 100 BW2100 CSR2100 CSR2100N CSH2100N 125 BW2125 CSR2125 CSR2125N CSH2125N 150 BW2150 CSR2150 CSR2150N CSH2150N 200 BW2200 CSR2200 CSR2200N CSH2200N Load Side Lug Kit for BW and CSR Breakers 1 MCBK225 5 5 5 5 5 Wiring Diagrams Catalog Number—CMB3242B200BS 47a. Bonded Neutral 1 2 3 4 5 6 7 8 9 10 11 12 13 23 24 25 26 27 28 29 30 31 32 14 34 15 35 16 36 17 37 18 38 19 39 20 40 21 41 22 42 Catalog Numbers—CMBP200BTS, CMBB150BTS 47c. 5 Install 200 Ampere Maximum Service Disconnect Type CSR 2 5 A 5 B 5 33 5 Bonded Neutral 5 A B Line N 5 Bonded Neutral 5 5 Wiring Diagram Key #14-2/0 AWG #14-2 AWG #6-250 AWG Service Disconnect Type CSR A N B Line Wiring Diagram Key #14-2 AWG #14-4 AWG #6-2/0 AWG #6-250 AWG 5 5 Catalog Number—CMB24L125BTS 47d. 5 B A 5 5 5 12 34 A Line N B 5 Bonded Neutral 5 5 5 Wiring Diagram Key #14-1/0 AWG #14-6 AWG #14-1/0 AWG #6-250 AWG 5 5 Notes 1 When a provision for main is provided, order one of the main breakers listed in this table. All panels are dual labeled to accept Types BW, CSR and CSR Main Breakers. 2 Factory-installed MCBK225 Kit for C/B load lugs. 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-43 5.9 5 Meter Breakers Catalog Numbers—CMB88B200BTS, CMB88B150BTS 48a. Catalog Number—MB1212L200BTS 48e. Service Disconnect Type CSR 200 Ampere Maximum Bonded Neutral 5 A 5 1 2 3 4 5 6 7 8 5 5 B A Line N 5 5 5 5 5 A B Ground Bar 1 2 3 4 5 6 7 8 9 10 11 12 Wiring Diagram Key Wiring Diagram Key #14-1/0 AWG #14-6 AWG #6-2/0 AWG #6-250 AWG #4-300 AWG #14-2/0 AWG #6-350 kcmil #6-300 kcmil Catalog Number—MB48B200BTS 48c. Catalog Number—CMB2424B200BTS 48f. A 200A Maximum Service Disconnect Type BW or CSR 5 5 N B Bonded Neutral 5 Group Metering and Meter Breakers A Line N B Bonded Neutral B 5 200 Ampere Maximum Service Disconnect Type CSR 1 2 3 4 5 6 7 8 5 5 A 5 Line N B L1 5 L2 Bonded Neutral Wiring Diagram Key #14-1/0 AWG #14-6 AWG #6-2/0 AWG #6-250 AWG 5 5 5 Catalog Number—CMB1212B200BTS 48d. 5 5th Jaw Factory Installed on CMB1212B200BTSD and CMB1212P200BTSD Only 5 A B Bonded Neutral 5 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Wiring Diagram Key #14-4 AWG #6-350 kcmil #6-2/0 AWG #4-300 kcmil Line N 5 5 200 Ampere Maximum Service Disconnect Type CSR or CSH 5 5 5 1 2 3 4 5 6 7 8 9 10 11 12 5 V1-T5-44 Wiring Diagram Key #14-4 AWG #6-350 kcmil #6-2/0 AWG #4-300 kcmil #6-300 kcmil Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Group Metering and Meter Breakers Meter Breakers Catalog Number—CMB1212L200BTS 49a. Catalog Numbers—MBP200SD, CMBXB200BTS, CMBXP200BTS 49c. 5th Jaw Factory Installed on CMB1212L200BTSD Only B 5 5 CMBXB200BTS & CMBXP200BTS B included lever by pass meter socket A A 5.9 N 5 Line N Bonded Neutral 5 5 5 1 2 3 4 5 6 7 8 9 10 11 12 5 CMBXB200BTS factory installed 200A Max Service Disconnect type CSR Wiring Diagram Key #14-4 AWG #6-350 kcmil #6-2/0 AWG #6-300 kcmil 5 5 MBP200SD install 200A Max Service Disconnect Type BW or CSR 5 5 Wiring Diagram Key #6-2/0 AWG #6-350 kcmil #1-300 kcmil #6-300 kcmil Catalog Number—CMB2436B200BTS 49b. A B Line N 5 5 Catalog Numbers—CMB1212B150BTS, CMBX1212B200BTS, CMB1212B200BTS, CMB1212P200BTS, CMBX1212P200BTS 49d. 5th Jaw Factory Installed on CMB1212B200BTSD and CMB1212P200BTSD Only Bonded Neutral A B Bonded Neutral 5 5 5 5 Line N 5 5 200A Max. Service Disconnect Type CSR or CSH 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 Wiring Diagram Key #14-4 AWG #6-350 kcmil #6-2/0 AWG Maximum of 12 twin #4-300 kcmil Breakers as Shown 5 200 Ampere Maximum Service Disconnect Type CSR or CSH 1 2 3 4 5 6 7 8 9 10 11 12 5 Wiring Diagram Key #14-4 AWG #6-350 kcmil #6-2/0 AWG #4-300 kcmil #6-300 kcmil 5 5 5 CMBX1212B200BTS & CMBX1212P200BTS include lever bypass meter socket 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-45 5.9 5 Group Metering and Meter Breakers Meter Breakers Catalog Numbers—MBT48B200BTS, MBT48P200BTS, MBT48B150BTS, MBT48P150BTS 50a. 5 A Catalog Numbers—MBB150BTSC, MBB150BTSCR, MBB200BTSCR and MBB200BTSC 50c. A B B Line N 5 5 5 Included in MBB150BTSCR 5 Factory or Field installed. 15A or 200A Max. Service Disconnect 5 5 5 5 5 5 5 Catalog Numbers—CMBX3242P200BTS, CMBX3242B200BTS 50b. 5 A 5 Wiring Diagram Key #6-2/0 AWG #6-350 kcmil #6-250 kcmil #1-300 kcmil Catalog Numbers—MB816P200STD, MB816B200BTS, MB816B200BTSCU, MB816P200BTS, MB816P200BTSCU and MB816P200BTSD 50d. A B Line N Bonded/ Neutral 5 5 CMBX3242P200BTS 200 A Max. Service Disconnect Type CSR or CSH (not included) 5 CMBX3242B200BTS 200 A Max. Service Disconnect Factory Installed Type CSR or CSH 5 5 1 2 3 4 5 5 6 7 8 9 10 5 11 13 12 14 15 17 16 18 20 5 5 Bonded Neutral Includes Lever Bypass Meter Socket Line N B 5 5 Line N Wiring Diagram Key #6-2/0 AWG #6-350 kcmil #1-300 kcmil #6-300 kcmil 12 34 56 78 19 25 29 33 37 21 23 27 31 35 39 200A Maximum Service Disconnect Type CSR Bonded Neutral 1 3 5 7 9 11 13 15 2 4 6 8 10 12 14 16 200A Maximum Service Disconnect Type BW or CSR Wiring Diagram Key #14-4 AWG #6-350 kcmil #6-2/0 AWG #6-300 kcmil #6-300 kcmil Maximum of 10 Twin Breakers as shown 22 24 26 28 30 32 34 36 38 40 41 42 Wiring Diagram Key #14-4 AWG #6-350 kcmil #6-2/0 AWG #6-300 kcmil 5 5 5 5 V1-T5-46 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Group Metering and Meter Breakers Meter Breakers 5.9 Catalog Numbers—MBB150BTS, MBP200SD, MBB200BTS, MBP200BTS, MBP200BTSD, CMBXB200BTS and CMBXP200BTS 51a. A 5 5 B 5 Line N 5 5 Bonded Neutral 5 200A Maximum Service Disconnect Type BW or CSR 1 5 5 5 Wiring Diagram Key #6-2/0 AWG #6-350 kcmil #1-300 kcmil #6-300 kcmil 5 5 5 Catalog Numbers—MB2040P200SD, MB2040B200BTS, MB2040P200BTS, MB2040B150SD and MB2040B200SD 51b. A 5 B 5 Line N 5 Bonded Neutral 5 200A Maximum Service Disconnect Type BW or CSR 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 5 5 5 5 Wiring Diagram Key #14-4 AWG #6-350 kcmil #6-2/0 AWG 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-47 5.9 5 Metering Products Meter Breakers Contents Residential Meter Breakers Description 5 Residential Meter Breakers . . . . . . . . . . . . . . . . . Non-EUSERC Combination Service Entrance Devices 100–200A Styles. . . . . . . . . . . . . . . . . . Meets EUSERC Requirements Service Entrance Devices 100–225A West Coast All-In-One Design . . . . . . . . . . . . . . . Mechanical Interlock Cover . . . . . . . . . . . . . . . . . . House Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . Commercial Safety Sockets . . . . . . . . . . . . . . . . . CH Style Renovation Solutions . . . . . . . . . . . . . . . Aluminum Meter Breakers . . . . . . . . . . . . . . . . . . 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Meets EUSERC Requirements Service Entrance Devices 100–225A Meets EUSERC Requirements Service Entrance Devices 100–225A Product Description Eaton is proud to introduce a new line of West Coast/ EUSERC Meter Breaker units. The new EUSERC devices complement the existing standard meter breaker devices. Customers who are interested in the complete meter breaker line of products can refer to Technical Data TD.31F.01.T.E. Features, Benefits and Functions ● ● ● ● ● Application Description Eaton’s line of EUSERC required devices adhere to the agreed upon standards. EUSERC utilities are predominately located in the western United States, but some eastern and midwestern utilities are also members. These units can also be used in many Non-EUSERC areas. ● ● ● ● 5 Single-phase, three-wire, 120/240V, 10 kAIC Larger 250 kcmil lugs and additional knockouts for ease of installation Box type main lugs are included Factory-installed neutrals Hub provisions on top endwall. If hubs are required, order “DS” type hubs Ring type sockets are provided with a sealing ring Padlockable device covers provide an additional measure of security and help prevent tampering Most units have center keyhole for easy oneperson installation NEMA 3R rainproof construction 5 5 5 5 5 5 V1-T5-48 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Page V1-T5-37 V1-T5-39 V1-T5-59 V1-T5-65 V1-T5-75 V1-T5-83 V1-T5-86 V1-T5-87 Metering Products Meter Breakers 5.9 Catalog Number Selection 5 MBE 20 40 B 200 B S Meter Breaker Type MB = 1-inch (25.4 mm) BR Type MBE = 1-inch (25.4 mm) BR Type—EUSERC CMB = 0.75-inch (19.1 mm) CH Type CMBE = 0.75-inch (19.1 mm) CH Type—EUSERC MBED = 7-inch (177.8 mm) deep MBER = 1-inch (25.4 mm) BR Type—EUSERC ranch CMBER = 0.75-inch (19.1 mm) CH Type—EUSERC ranch MBEB = 1-inch (25.4 mm) BR Type back-to-back MBX = Xcel approved lever bypass meter breaker Spacing Number of spaces Poles Maximum number of poles Main B = Main breaker included P = Provision for main L = Main lug Amperes Amperage of unit 5 D CU C CR 5 Accessories/Modifications = 5th jaw and horn bypass = Copper = Single cover compact design = Two cover compact design Mounting S = Surface F = Flush/stucco Breaker Feed BT = Bottom and top B = Bottom only T = Top only 5 5 Last Digits G = Suffix = GA PWE spec R 1 = Suffix = ECCN renovation PV = Suffix = PV rated units 6 = 2 x 6 construction A = Aluminum enclosure 5 5 5 5 Note 1 Not available in CR. 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-49 5.9 5 5 5 5 5 5 5 Metering Products Meter Breakers Product Selection Note: See knockout drawings on Pages V1-T5-68 through V1-T5-74 for hub information. Combination Service Entrance Devices—EUSERC Ampere Rating By-pass Service kAIC Jaws Distribution Dimensions and Enclosure Shape 1 Page Numbers Main Branch Breaker Type Wiring Knockout 1 Catalog Number—Surface Catalog Number—Flush Ring Style Meter Mains (no distribution section included) 125 None OH/UG 2 4 2/4 MLO BR 2 V1-T5-55 V1-T5-70 MBE24L125BTS MBE24L125BTF 125 None OH/UG 2 4 2/4 MLO CH 2 V1-T5-53 V1-T5-70 CMBE24L125BTS 3 — 150 None OH/UG 22 4 None CSH2150N None 3 V1-T5-52 V1-T5-70 CMBEB150BTS 3 — 200 None OH/UG 10 4 None CSR2200 None 3 V1-T5-56 V1-T5-70 MBEB200BTS MBEB200BTF — 200 None OH/UG 22 4 None CSH2200N None 3 V1-T5-52 V1-T5-70 CMBEB200BTS 3 5 200 None OH/UG 2 4 2/4 MLO BR 3 V1-T5-56 V1-T5-70 MBE24L200BTS MBE24L200BTF 200 None OH/UG 2 4 2/4 MLO CH 3 V1-T5-53 V1-T5-70 CMBE24L200BTS 3 — 5 Ring Style All-in-Ones (includes distribution section) 100 None OH/UG 10 4 12/24 BR2100 BR 2 V1-T5-53 V1-T5-70 MBE1224B100BTS MBE1224B100BTF 5 100 None UG 10 4 14/28 BR2100 BR 4 V1-T5-55 V1-T5-69 MBE1428B100BS MBE1428B100BF 5 100 None OH 10 4 12/24 BR2100 BR 9 V1-T5-58 V1-T5-71 MBE1224B100TS — 125 None OH/UG 10 4 12/24 BR2125 BR 2 V1-T5-53 V1-T5-70 MBE1224B125BTS MBE1224B125BTF 5 125 None OH 10 4 12/24 BR2125 BR 9 V1-T5-58 V1-T5-71 MBE1224B125TS — 125 None UG 10 4 18/36 BR2125 BR 5 V1-T5-54 V1-T5-69 — MBE1836B125BF 150 None OH/UG 10 4 4/8 CSR2150 BR 19 — — MBER48B150BTS 48 — 150 None OH/UG 22 4 8/8 CSH2150N CH 19 — — CMBER88B150BTS 348 — 150 None OH/UG 22 4 8 CSH2150N CH 3 V1-T5-53 V1-T5-70 CMBE88B150BTS 34 CMBE88B150BTF 34 150 None UG 22 4 32/42 CSH2150N CH 7 V1-T5-52 V1-T5-69 CMBE3242B150BS 3 — 150 None UG 10 4 20/40 CSR2150 BR 6 V1-T5-54 V1-T5-69 — MBE2040B150BF 5 5 5 5 5 5 5 5 Notes 1 See Page V1-T5-68 for box details. 2 Interrupting rating is dependent on the main breaker that is installed. 3 Unit has copper bus. 4 Units come with feed-through lugs. 5 Please use RH-Type hubs on top end wall for overhead feed. 6 Includes factory-mounted 2.50-inch hub on bottom endwall. UG feed only. 7 Semi flush flange, not full stucco flange. 8 Units include a two-pole provision for secondary main 70A max. Type BR, BRH, BRHH. 5 5 5 5 5 5 5 5 5 5 5 V1-T5-50 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 5.9 Metering Products Meter Breakers Note: See knockout drawings on Pages V1-T5-68 through V1-T5-74 for hub information. 5 Combination Service Entrance Devices—EUSERC, continued 5 Ampere ByRating pass Service kAIC Jaws Distribution Main Dimensions and Enclosure Shape 1 Page Numbers Branch Breaker Type Wiring Knockout 1 Catalog Number—Surface Catalog Number—Flush 5 5 Ring Style All-in-Ones (includes distribution section), continued 150 None OH/UG 22 4 20/40 CSR2150 BR — V1-T5-55 — MBE2040B150BTS 6 — 150 None OH/UG 10 4 4/8 CSR2150 BR 3 V1-T5-56 V1-T5-70 MBE48B150BTS — 200 None OH/UG 10 4 4/8 CSR2200 BR 3 V1-T5-56 V1-T5-70 MBE48B200BTS 4 MBE48B200BTF 4 200 None OH/UG 22 4 8 CSH2200N CH 3 V1-T5-53 V1-T5-70 CMBE88B200BTS 34 CMBE88B200BTF 34 200 None OH/UG 10 4 8 CSR2200 BR 3 V1-T5-56 V1-T5-70 MBE88B200BTS — 200 None OH/UG 10 4 4/8 CSR2200 BR 19 V1-T5-58 V1-T5-73 MBER48B200BTS 48 — 200 None OH/UG 10 4 4/8 CSR2200 BR 19 V1-T5-58 V1-T5-73 MBER48B200BTS 48 — 4 8/16 Provision BR 10 V1-T5-57 V1-T5-71 MBE816P200TSCU 36 — 4 8/16 Provision BR 10 V1-T5-57 V1-T5-71 MBE816P200TS 46 — MBE1212L200BTF 200 None OH/UG 2 200 None OH 2 4 6–2 Pole Main Lug CH 5 V1-T5-52 V1-T5-69 CMBE1212L200BS 3 4 6–2 Pole Main Lug BR 9 V1-T5-57 V1-T5-69 MBE1212L200BTS — 5 5 5 5 5 200 None UG 2 200 None OH/UG 2 200 None OH 10 4 20/40 CSR2200 BR 10 V1-T5-57 V1-T5-71 MBE2040B200TS 6 MBE2040B200TF 5 200 None UG 10 4 20/40 CSR2200 BR 6 V1-T5-54 V1-T5-69 MBE2040B200BS 6 MBE2040B200BF 5 200 None OH/UG 22 4 20/40 CSR2200 BR — V1-T5-55 — MBE2040BH200BTS 6 — — MBE3042B200BF 200 None OH/UG 22 4 20/40 CSR2200 BR — V1-T5-55 — MBE2040BH200BTF 6 200 None UG 22 4 30/42 CSR2200 BR 7 V1-T5-54 — — CMBE3242B200BF 200 None UG 22 4 32/42 CSH2200N CH 7 V1-T5-52 V1-T5-69 200 None UG 22 4 40 CSR2200 BR 12 V1-T5-58 — MBE4040B200BSH 6 — 200 None OH/UG 22 4 40 CSR2200 BR 12 V1-T5-58 — MBE4040B200BTS MBE4040B200BTF 7 200 None OH/UG 22 4 42 CSH2200N CH 12 V1-T5-57 — CMBE4242B200BTS 3 — 200 None OH/UG 10 4 20/40 CSR2200 BR 18 V1-T5-55 V1-T5-73 MBE2040B200BTS 6 MBE2040B200BTF 6 225 None OH/UG 10 4 20/40 CSR2225 BR 18 V1-T5-58 V1-T5-73 MBE2040B225BTS 6 MBE2040B225BTF 6 225 None UG 22 4 30/42 CSR2225 BR 7 V1-T5-55 — — MBE3042B225BF V1-T5-69 CMBE3242B225BS 3 None UG 22 4 32/42 CSH2225N CH 7 V1-T5-52 CMBE3242B225BF 5 5 5 CMBE3242B200BS 3 225 5 3 3 Notes 1 See Page V1-T5-68 for box details. 2 Interrupting rating is dependent on the main breaker that is installed. 3 Unit has copper bus. 4 Units come with feed-through lugs. 5 When a provision for main is provided, order one of the main breakers listed on Page V1-T5-68. All panels are dual labeled to accept Types BW or CSR Main Breakers. 6 Please use RH-Type hubs on top end wall for overhead feed. 7 Includes factory-mounted 2.50-inch hub on bottom endwall. UG feed only. 8 Semi-flush flange, not full stucco flange. 9 Units include a two-pole provision for secondary main 70A max. Type BR, BRH, BRHH. 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-51 5.9 5 Meter Breakers Wiring Diagrams Catalog Numbers—CMBE3242B150BS, CMBE3242B200BS, CMBE3242B200BF, CMBE3242B225BS and CMBE3242B225BF 56a. 1 2 3 4 5 6 7 8 9 10 11 12 13 23 24 25 26 27 28 29 30 31 32 14 34 15 35 16 36 17 37 18 38 5 19 39 20 40 21 41 5 22 42 5 5 5 Bonded Neutral 5 33 Bonded Neutral N 5 5 A 5 Line 2 4 6 8 10 12 14 16 18 20 21 22 Bonded Neutral 1 3 5 7 9 11 13 15 17 19 5 5 Install 200 Ampere Maximum Service Disconnect Type CSR 2 A A 5 5 Catalog Numbers—CMBEB150BTS and CMBEB200BTS 56d. B Service Disconnect 5 5 Wiring Diagram Key #14-4 AWG #6-1/0 AWG #6-250 AWG Wiring Diagram Key #14-2 AWG #14-4 AWG #6-2/0 AWG #6-250 AWG Catalog Numbers—CMBE2222P125BF and CMBE2222P125BS Bonded Neutral 5 B N 5 5 Line Service Disconnect Type CSR 5 5 B A 5 5 2 4 6 8 10 12 1 3 5 7 9 11 Bonded Neutral 5 Catalog Number—CMBE1212L200BS 56c. Bonded Neutral 5 Group Metering and Meter Breakers B A N Line Wiring Diagram Key #14-4 AWG #6-2/0 AWG #14-2/0 AWG #6-250 AWG Line N B Bonded Neutral Wiring Diagram Key #14-2/0 AWG #14-2 AWG #6-250 AWG Note 1 Factory-installed MCBK225 kit for C/B load lugs. 5 5 5 5 5 V1-T5-52 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Group Metering and Meter Breakers Meter Breakers Catalog Number—CMBE24L125BTS 57a. 5.9 Catalog Numbers—CMBE88B200BTS, CMBE88B200BTF, CMBE88B150BTS and CMBE88B150BTF 57c. 5 Service Disconnect Type CSR 200 Ampere Maximum 5 B A A 5 B 5 12 34 Line N B Bonded Neutral 1 2 3 4 5 6 7 8 B A Line N Wiring Diagram Key #14-1/0 AWG #14-6 AWG #14-1/0 AWG #6-250 AWG 5 Bonded Neutral A 5 5 5 Wiring Diagram Key #14-1/0 AWG #14-6 AWG #6-2/0 AWG #6-250 AWG #4-300 AWG Catalog Number—CMBE24L200BTS 57b. 5 5 5 Catalog Numbers—MBE1224B100BTS, MBE1224B100BTF, MBE1224B125BTS and MBE1224B125BTF 57d. 5 B A 1 2 3 4 5 Main 12 34 A Line N B Bonded Neutral A Bonded Neutral Wiring Diagram Key #14-6 AWG #14-1/0 AWG #6-250 AWG B 5 5 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 5 5 5 5 Wiring Diagram Key #14-6 AWG #14-1/0 AWG #14-2/0 AWG #6-250 AWG 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-53 5.9 5 5 Bonded Neutral 5 Catalog Numbers—MBE1212L200BF and MBE1212L200BS 1 3 5 7 9 11 5 A N 5 Catalog Number—MBE1836B125BF 58b. Bonded Neutral 5 5 Line N Wiring Diagram Key #14-6 AWG #6-1/0 AWG #6-250 AWG Catalog Number—MBE3042B200BF 58d. 1 2 3 5 4 6 7 8 9 11 10 12 13 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 15 17 19 21 23 25 27 29 31 33 35 37 39 41 Service Disconnect Service Disconnect Type BW or CSR 5 5 5 5 Bonded Neutral 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 33 34 35 36 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 Bonded Neutral 5 B Line Wiring Diagram Key #14-4 AWG #6-2/0 AWG #6-250 AWG Bonded Neutral 5 5 B A 5 5 2 4 6 8 10 12 Service Disconnect Type BW or CSR 5 5 Bonded Neutral 5 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 Bonded Neutral 5 Meter Breakers Catalog Numbers—MBE2040B150BF, MBE2040B200BS and MBE2040B200BF 58a. Bonded Neutral 5 Group Metering and Meter Breakers A N B Line Wiring Diagram Key #14-4 AWG #6-2/0 AWG #14-2/0 AWG #6-250 AWG N A LINE B Wiring Diagram Key #14-4 AWG #6-2/0 AWG #6-250 AWG 5 5 5 5 5 5 5 5 5 V1-T5-54 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Group Metering and Meter Breakers Meter Breakers Catalog Numbers—MBE1428B100BS and MBE1428B100BF 59a. Bonded Neutral Bonded Neutral Service Disconnect A B Line N Catalog Number—MBE3042B225BF 59c. 1 2 3 5 4 6 7 8 9 11 13 10 12 5 5 5 5 5 Service Disconnect Type BW or CSR Wiring Diagram Key #14-4 AWG #6-2/0 AWG #14-2/0 AWG #6-250 AWG N A Catalog Numbers—MBE2040B200BTS, MBE2040B150BTS, MBE2040BH200BTS and MBE2040BH200BTF 59b. LINE B 5 Wiring Diagram Key #14-4 AWG #6-2/0 AWG #6-250 AWG 5 5 Catalog Numbers—MBE24L125BTS and MBE24L125BTF 59d. A B 200A Max. Service Disconnect B A 5 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 15 17 19 21 23 25 27 29 31 33 35 37 39 41 5 Bonded Neutral Bonded Neutral 2 4 6 8 10 12 14 16 18 20 22 24 25 26 27 28 1 3 5 7 9 11 13 15 17 19 21 23 5.9 5 5 5 5 5 1 2 34 56 B A N Bonded Neutral Wiring Diagram Key #14-6 AWG #14-1/0 AWG #6-250 AWG 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 A Line N B Bonded Neutral 5 5 5 5 Wiring Diagram Key #14-1/0 AWG #14-6 AWG #14-2/0 AWG #6-250 AWG 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-55 5.9 5 Group Metering and Meter Breakers Meter Breakers Catalog Numbers—MBE48B150BTS, MBE48B200BTS, MBE48B200BTF 60a. 5 5 5 200A Maximum Service Disconnect Type BW or CSR A A B B 1 2 34 56 5 1 2 3 4 5 6 7 8 5 5 Catalog Numbers—MBE24L200BTS and MBE24L200BTF 60c. A Line N B L1 A Line N B Bonded Neutral L2 Bonded Neutral 5 5 5 5 Catalog Numbers—MBEB200BTS and MBEB200BTF 60b. Catalog Number—MBE88B200BTS 60d. 200A Maximum Service Disconnect Type BW or CSR 200A Maximum Service Disconnect Type BW or CSR 5 5 Wiring Diagram Key #14-1/0 AWG #14-6 AWG #14-2/0 AWG #6-250 AWG Wiring Diagram Key #14-1/0 AWG #14-6 AWG #6-2/0 AWG #6-250 AWG A A B B 5 5 5 5 MCBK225 Kit for C/B Load Lugs A Line N B Bonded Neutral 5 5 Wiring Diagram Key #14-2/0 AWG #6-2/0 AWG #6-250 AWG 5 A Line N B 1 2 3 4 5 6 7 8 Wiring Diagram Key #14-1/0 AWG #14-6 AWG #6-2/0 AWG #6-250 AWG 5 5 5 5 5 5 5 5 5 V1-T5-56 Bonded Neutral 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Group Metering and Meter Breakers Meter Breakers Catalog Numbers—MBE816P200TS and MBE816P200TSCU 61a. A 5.9 Catalog Number—MBE1212L200BTS 61d. B A 5 B 5 Line N 5 Bonded Neutral 1 3 5 7 9 11 13 15 2 4 6 8 10 12 14 16 N 200A Maximum Service Disconnect Type BW or CSR 1 2 3 4 5 5 5 6 7 8 9 10 11 12 Wiring Diagram Key #14-4 AWG #6-350 kcmil #6-2/0 AWG #6-300 kcmil #6-300 kcmil 5 5 Wiring Diagram Key #14-4 AWG #6-350 kcmil #6-2/0 AWG #6-300 kcmil Catalog Numbers— MBE2040B200TS and MBE2040B200TF 61b. A 5 Bonded Neutral 5 5 5 Catalog Number—CMBE1212L200TS 61e. B A 5 N B Bonded Neutral Line N 5 5 Bonded Neutral 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 5 200A Maximum Service Disconnect Type BW or CSR 2 3 4 5 5 5 6 7 8 9 10 11 12 5 Wiring Diagram Key #14-4 AWG #6-350 kcmil #6-2/0 AWG #6-300 kcmil Wiring Diagram Key #14-4 AWG #6-350 kcmil #6-2/0 AWG 5 Catalog Number—CMBE4242B200BTS 61f. 5 B 1 A B 2 3 LINE N B 4 5 6 A Wiring Diagram Key #14-4 AWG #6-350 kcmil #6-2/0 AWG 5 Factory Installed Service Disconnect Type CSR Bonded Neutral A 5 5 Catalog Number—MBE1212L200BTS 61c. A 1 Bonded B Neutral Wiring N Diagram Key #14-6 AWG #14-1/0 AWG #6 AWG-250 kcmil 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 5 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 5 5 5 5 5 5 V1-T5-57 5.9 5 Group Metering and Meter Breakers Meter Breakers Catalog Numbers—CMBER88B200BTS and CMBER88B200BTF 62a. 5 Catalog Numbers—MBE2040B225BTS, MBE2040B225BTF 62d. 225A Max. Service Disconnect Service Disconnect Type CSR or CSH Max 200A 5 A B A B A B 5 1 2 3 4 5 6 7 8 5 5 A 5 Line N B Secondary Service Disconnect 70A Max Bonded Neutral Wire Range 5 #14-1/0 #5-2/0 AWG #14-6 AWG #5-250 AWG #4-300 AWG 5 N Bonded Neutral Wiring Diagram Key #14-6 AWG #14-1/0 AWG #6-250 AWG 5 5 5 Catalog Numbers—MBE4040B200BTS and MBE4040B200BSH 62b. 5 A 5 A B 5 5 Bonded B Neutral A 5 Line N 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 5 5 N Wiring Diagram Key #14-6 AWG #14-1/0 AWG #6 AWG-250 kcmil 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 5 5 B Factory Installed Service Disconnect Type BW 5 5 Catalog Numbers—MBE1224B125TS and MBE1224B100TS 62e. Bonded Neutral 125A Maximum Service Disconnect Type BR, or BRH 1 3 5 7 9 11 13 15 17 19 21 23 2 4 6 8 10 12 14 16 18 20 22 24 Equipment Ground Wiring Diagram Key #14-4 AWG #14-1/0 AWG #6-350 kcmil Catalog Numbers—MBER48B200BTS and MER48B200BTF 62c. Service Disconnect Type CSR or CSH Max 200A 5 A B 5 5 5 5 A Line N 1 2 3 4 5 6 7 8 B Secondary Service Disconnect 70A Max Bonded Neutral Wire Range 5 #14-1/0 #14-6 AWG 5 V1-T5-58 #5-2/0 AWG #5-250 AWG #4-300 AWG Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Meter Breakers 5.9 Contents West Coast All-In-One Design Description Residential Meter Breakers . . . . . . . . . . . . . . . . . . Non-EUSERC Combination Service Entrance Devices 100–200A Styles . . . . . . . . . . . . . . . . . . Meets EUSERC Requirements Service Entrance Devices 100–225A . . . . . . . . . . . . . . . . . . . . . . . West Coast All-In-One Design Mechanical Interlock Cover . . . . . . . . . . . . . . . . . . House Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . Commercial Safety Sockets. . . . . . . . . . . . . . . . . . CH Style Renovation Solutions . . . . . . . . . . . . . . . Aluminum Meter Breakers . . . . . . . . . . . . . . . . . . Page 5 V1-T5-37 5 V1-T5-39 5 V1-T5-48 5 V1-T5-65 V1-T5-75 V1-T5-83 V1-T5-86 V1-T5-87 5 5 5 5 5 5 West Coast All-In-One Design 5 Product Description 5 A metering device that may contain a meter socket, main breaker and distribution section within the same enclosure. Features, Benefits and Functions ● ● ● ● ● ● 5 Semi-flush mounting. 7-inch design ideal for stucco homes Endwall knockouts are easily accessible for future wiring without damaging stucco Knockout in back of case for mounting car-charging receptacle in garage (meets future electric car requirements) Outboard split neutral for easy wiring Commercial grade main breaker Value-added kits available: Hub adapter plate 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-59 5.9 5 5 Metering Products Meter Breakers Product Selection MBED3042B200BF 7-Inch Deep Meter Breaker—Standard Design OH/NG Main Branch Breaker Type Catalog Number— Flush FactoryInstalled Kits BW2100 BR MBED1836B100BF — BW2125 BR MBED1836B125BF — 20/40 BW2200 BR MBED2040B200BF — 20/40 BW2200 BR MBED2040B200BFN — 4 30/42 BW2200 BR MBED3042B200BF — 10 4 20/40 BW2225 BR MBED2040B225BF — UG 10 4 20/40 BW2225 BR MBED2040B225BFN — UG 10 4 30/42 BW2225 BR MBED3042B225BF — 5 Ampere Rating Bypass Service kAIC Jaws Distribution 5 100 None UG 10 4 18/36 125 None UG 10 4 18/36 5 200 None UG 10 4 5 200 1 None UG 10 4 200 None UG 10 5 225 None UG 225 1 None 5 225 None 5 Accessories 5 5 Hub Adapter Plate 5 Description Catalog Number Hub adapter plate MBEDADPT 5 Note 1 Main Breaker Bus connected to 20/40 distribution. Main and Disconnect in same compartment. 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 V1-T5-60 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Meter Breakers 5.9 Wiring Diagrams Typical Wiring Diagram for Catalog Numbers MBED3042B200BF, MBED3042B225BF, MBED3042BH200BF 5 Typical Wiring Diagram for Catalog Numbers MBED2040B200BFN, MBED2040B225BFN 5 5 5 5 5 5 5 5 5 5 Typical Wiring Diagram for Catalog Numbers MBED1836B100BF, MBED1836B125BF Typical Wiring Diagram for Catalog Numbers MBED2040B200BF, MBED2040B225BF, MBED2040BH200BF, MBED2040BH225BF 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-61 5.9 5 Metering Products Meter Breakers Typical Wiring Diagram for Catalog Numbers MBEB2003040BB and MBEB2253040BB 5 Loadcenter Main Lugs 5 A 5 B Loadcenter Neutral N 5 5 A B A B 5 5 5 5 Line N 5 200A or 225A Max. Service Disconnect Type BW or CSR Factory Bonded Neutral Wiring Diagram Key #14-2/0 AWG #6-250 AWG 5 5 5 5 5 Dimensions and Knockouts Approximate Dimensions in Inches (mm) 7-Inch Deep Meter Breaker 5 Catalog Number— Flush Height Width Depth 5 MBED1836B100BF 38.00 (965.2) 14.19 (360.4) 7.00 (177.8) MBED1836B125BF 38.00 (965.2) 14.19 (360.4) 7.00 (177.8) 5 MBED2040B200BF 38.00 (965.2) 14.19 (360.4) 7.00 (177.8) MBED2040B200BFN 42.50 (1079.5) 14.19 (360.4) 7.00 (177.8) 5 MBED3042B200BF 42.50 (1079.5) 14.19 (360.4) 7.00 (177.8) 5 MBED2040B225BF 38.00 (965.2) 14.19 (360.4) 7.00 (177.8) MBED2040B225BFN 42.50 (1079.5) 14.19 (360.4) 7.00 (177.8) MBED3042B225BF 42.50 (1079.5) 14.19 (360.4) 7.00 (177.8) 5 5 5 5 5 5 5 5 5 V1-T5-62 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Meter Breakers 5.9 Approximate Dimensions in Inches (mm) 5 Catalog Numbers MBED2040B200BFN, MBED20408225BFN, MBED3042B200BF, MBED3042B225BF, MBED2040B200BF, MBED2040B225BF, MBED1836B100BF, MBED1836B125BF 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Knockout Configurations and Dimensions for MBED2040B200BFN, MBED20408225BFN, MBED3042B200BF, MBED3042B225BF, MBED2040B200BF, MBED2040B225BF,MBED1836B100BF, MBED1836B125BF 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-63 5.9 5 5 Metering Products Meter Breakers Approximate Dimensions in Inches (mm) Catalog Numbers MBEB2003040BB, MBEB2253040BB 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Knockout Configurations for MBEB2003040BB, MBEB2253040BB 5 5 5 5 5 5 5 5 5 5 5 5 V1-T5-64 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Meter Breakers 5.9 Contents Mechanical Interlock Cover Description Residential Meter Breakers . . . . . . . . . . . . . . . . . . Non-EUSERC Combination Service Entrance Devices 100–200A Styles . . . . . . . . . . . . . . . . . . Meets EUSERC Requirements Service Entrance Devices 100–225A . . . . . . . . . . . . . . . . . . . . . . . West Coast All-In-One Design. . . . . . . . . . . . . . . . Mechanical Interlock Cover House Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . Commercial Safety Sockets. . . . . . . . . . . . . . . . . . CH Style Renovation Solutions . . . . . . . . . . . . . . . Aluminum Meter Breakers . . . . . . . . . . . . . . . . . . Page 5 V1-T5-37 5 V1-T5-39 5 V1-T5-48 V1-T5-59 V1-T5-75 V1-T5-83 V1-T5-86 V1-T5-87 5 5 5 5 5 5 Meter Breaker with Interlock Cover 5 Mechanical Interlock Cover 5 Product Description 5 Covers mechanically interlock two breakers. Covers interlock main breaker with two-pole breaker mounted in the distribution section of the meter breakers. 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-65 5.9 5 5 Metering Products Meter Breakers Product Selection Meter Breaker with Interlock Cover Mechanical Interlock Cover Mechanical Interlock Deadfront Meter Breaker Catalog Number Mechanical Interlock Deadfront Meter Breaker Catalog Number MBDF1M CMB1212B200BTS MBDF1AM CMB2424M200BTS 5 CMB1212B200BTSD MBDF10M CMB24B200TFR 5 CMB1212P200BTSD 5 CMB1212P200BTS MBDF2M 5 MB816B200BTS MB816B200BTSCU 5 CMB24B200TSR MBDF11M CMBXP200BTS MBDF12M MB816P200BTS MB816P200BTSCU 5 5 5 MBDF4M 5 MBDF5M 5 MB2040B200BTS 5 MBDF6M 5 MBDF7M MBE3042B225BF MBDF14M CMBE88B150BTF CMBE88B150BTS MB2040P200SD CMBE88B200BTF MBE816P200TS CMBE88B200BTS MBE816P200TSCU CMB88B150BTS MBE2040B150BF CMB88B200BTS MBDF15M MBE48B150BTF MBE2040B200BF MBE48B150BTS MBE2040B200BS MBE48B200BTF MBE2040B200TF MBE2040B200TS 5 MBE3042B200BF MB2040P200BTS MBE2040B150BS 5 CMBX3242B200BTS CMBX3242P200BTS MBDF13M MB816P200STD MBDF3M CMBXB200BTS MBE48B200BTS MBDF16M MBE88B150BTF MBE2040P200TF MBE88B150BTS MBE2040P200TS MBE88B200BTF CMBE3242B150BF MBE88B200BTS 5 CMBE3242B150BS CMBE3242B200BF MBE2040BH200BTF 5 CMBE3242B200BS MBE2040BH200BTS CMB3242B150BS MBE2040B150BTF CMB3242B200BS MBE2040B150BTS CMBE4242B200BSH MBE2040B200BTF CMBE4242B200BTF MBE2040B200BTS CMBE4242B200BTS MBE2040B200BTSV MBE4040B200BSH MBE2040B225BTF 5 MBE4040B200BSHH MBE2040B225BTS 5 MBE4040B200BTS 5 MBDF8M 5 5 MBDF9M MBDF17M MBE2040BC200BTS MBE4040B200BTF 5 5 5 5 5 5 5 V1-T5-66 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Meter Breakers Meter Breaker Parts 1 Catalog Number Description 5th Jaw Kits Technical Data and Specifications 5 Wire Size Chart 5 Main Wire Size Range Cu/Al 60ºC or 75ºC for Line Terminals BR250 #14–4 kcmil Compact and standard styles (MB and CMB) MB5JAWKIT BR260 #4–1/0 kcmil EUSERC style IMM5JKOP BR270 #4–1/0 kcmil BR280 #4–1/0 kcmil BR290 #4–1/0 kcmil BR2100 #4–1/0 kcmil BW2125 #2–300 kcmil BW2150 #2–300 kcmil Horn Bypass Kits Ringless Style units only (MB and CMB) MBHBPKIT Hub Selection Chart Hub Size Dimensions in Inches (mm) Catalog Number BW2200 #2–300 kcmil 1.00 (25.4) DS100H2 CSR2125 #2–300 kcmil 1.25 (31.8) DS125H2 CSR2150 #2–300 kcmil 1.50 (38.1) DS150H2 CSR2200 #2–300 kcmil 2.00 (50.8) DS200H2 CSR2125N #1/0–250 kcmil 2.50 (63.5) DS250H2 CSR2150N #1/0–250 kcmil DS300H2 CSR2200N #1/0–250 kcmil 125A main lugs — 200A main lugs — MCBK225 #2–300 kcmil 3.00 (76.2) Top Endwall (Surface) 5.9 5 5 5 5 5 5 5 5 5 5 5 Hub Provision Catalog Number 5 Wire Size is Determined by the Circuit Breaker Installed in the Enclosure DS100H2 DS125H2 Maximum DS150H2 DS200H2 Wire/Application Wire Size Ampere Rating DS250H2 Aluminum—Standard 250 kcmil 200 DS300H2 Aluminum—Service Entrance 250 kcmil 225 Copper—Standard and Service Entrance 250 kcmil 225 DS900AP (Adapter Plate if using DS___H1 hubs only) 2 5 5 5 5 Notes 1 For breakers under 70A used in backfed applications, add “B” to the end of the catalog string to get the appropriate “hold-down” version. 2 Use when DS H1 Type 1, 1.25 and 1.50-inch hubs are needed. Use DS...H2 hubs for bottom endwalls (for all units). Use RH hubs for top endwalls on semi-flush units. Use DS...H2 hubs for top endwalls on surface devices. 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-67 5.9 5 5 Metering Products Meter Breakers Dimensions and Knockouts Approximate Dimensions in Inches (mm) Box Styles—Five Different Styles (Shapes) of Product 5 B A C D E 5 5 5 5 5 Box Dimensions 5 Box Number Height Width Depth Box Style 5 1 12.50 (317.5) 14.44 (366.7) 4.00 (101.6) A 2 23.88 (606.4) 14.44 (366.7) 5.38 (136.5) A 5 3 28.38 (720.7) 14.44 (366.7) 5.38 (136.5) A 5 4 34.13 (866.8) 14.44 (366.7) 5.38 (136.5) B 5 36.13 (917.6) 14.44 (366.7) 5.38 (136.5) B 5 6 43.38 (1101.7) 14.44 (366.7) 5.38 (136.5) B 7 46.88 (1190.6) 14.44 (366.7) 5.38 (136.5) B 5 8 19.75 (501.7) 7.50 (190.5) 4.00 (101.6) C 9 25.00 (635.0) 14.44 (366.7) 5.38 (136.5) C 5 10 32.38 (822.3) 14.44 (366.7) 5.38 (136.5) C 5 11 36.63 (930.3) 14.44 (366.7) 5.38 (136.5) C 12 34.38 (873.1) 22.00 (558.8) 5.38 (136.5) D 5 13 19.75 (501.7) 14.44 (366.7) 5.38 (136.5) E 14 39.91 (1013.7) 14.44 (366.7) 5.38 (136.5) C 5 15 23.88 (606.6) 13.00 (330.2) 4.94 (125.5) F 5 16 28.38 (720.9) 13.00 (330.2) 4.94 (125.5) F 17 34.19 (868.4) 22.13 (562.1) 5.00 (127.0) D 5 18 36.06 (915.9) 16.63 (422.4) 5.50 (139.7) A 19 28.38 (720.9) 14.44 (366.8) 4.94 (125.5) A 5 20 32.06 (814.3) 14.44 (366.8) 4.94 (125.5) C 21 25.50 (647.7) 14.44 (366.8) 4.94 (125.5) C 5 5 5 5 5 5 5 5 5 V1-T5-68 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com F Metering Products Meter Breakers 5.9 Approximate Dimensions in Inches (mm) Knockouts for Stucco and Surface Units Catalog Numbers— CMBE3242B200BF, CMBE3242B225BF, MBE2040B200BF, MBE2040B150BF, MBE1428B100BF, MBE1212L200BTF, MBE1836B125BF and MBE1212L200BTS 62a. Keyhole Knockouts on Sides for Stucco Units Only. 3-1/2 88.9 (88.9) Hub Provision Catalog Number 4-15/16 (125.4) Quantity DS100H2 1 DS125H2 1 DS150H2 1 DS200H2 1 DS250H2 1 DS300H2 1 DS900AP Top T op Stucco 5 Top Endwall (Surface) (Adapter Plate if using DS___H1 hubs only) 2 5 5 5 5 1 5 5 Top Endwall (Stucco) 3 Knockout Size Dimensions in Inches (mm) Quantity 1.25, 1.50, 2.00, 2.50 (31.8, 38.1, 50.8, 63.5) 1 1.00, 1.25, 1.50 (25.4, 31.8, 38.1) 1 0.50, 0.75, 1.00 (12.7, 19.1, 25.4) 1 0.50, 0.75 (12.7, 19.1) 3 0.50 (12.7) 3 5-5/16 (134.9) 5 5 5 5 Bottom Knockouts for Stucco and Surface Units Catalog Numbers— CMBE3242B150BS, CMBE3242B200BS, CMBE3242B225BS, CMBE1212L200BS, MBE2040B200BS, MBE1428B100BS, MBE1212L200BTS, CMB3242B150BS and CMB3242B200BS 62b. 5 5 Bottom Endwall Knockout Size Dimensions in Inches (mm) Quantity 0.50 (12.7) 7 0.50, 0.75 (12.7, 19.1) 4 0.50, 0.75, 1.00 (12.7, 19.1, 25.4) 1 1.00, 1.25, 1.50, 2.00 (25.4, 31.8, 38.1, 50.8) 1 1.25, 1.50, 2.00, 2.50, 3.00 (31.8, 38.1, 50.8, 63.5, 76.2) 1 5 5 5 5 Notes 1 For details regarding quantities, please contact the Technical Resource Center (TRC) at 1-877-ETN-CARE. 2 Use when DS H1 Type 1, 1.25 and 1.50-inch hubs are needed. 3 RH hubs are to be used for Top Endwall (Stucco) endwalls. Top Surface 5 5 5 5 5 5 4-15/16 (125.4) 5 5 Bottom 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-69 5.9 5 5 5 Meter Breakers Approximate Dimensions in Inches (mm) Knockouts for Stucco and Surface Units Catalog Numbers— CMBE88B150BTF, CMBE88B200BTF, MBE24L125BTF, MBE24L200BTF, MBE48B200BTF, MBEB200BTF, MBE1224B100BTF and MBE1224B125BTF 63a. Keyhole Knockouts on Sides for Stucco Units Only. 5 5 Metering Products 3-1/2 (88.9) 5 Top Endwall (Surface) Hub Provision Catalog Number DS100H2 1 DS125H2 1 DS150H2 1 DS200H2 1 DS250H2 1 1 DS300H2 DS900AP 5 5 Top Stucco Quantity (Adapter Plate if using DS___H1 hubs only) 2 1 Top Endwall (Stucco) 3 5 Knockout Size Dimensions in Inches (mm) 5 1.25, 1.50, 2.00, 2.50 (31.8, 38.1, 50.8, 63.5) 1 1.00, 1.25, 1.50 (25.4, 31.8, 38.1) 1 0.50, 0.75, 1.00 (12.7, 19.1, 25.4) 1 0.50, 0.75 (12.7, 19.1) 3 0.50 (12.7) 3 5 4-15/16 (125.4) 5 Bottom 5 5 5 5 5 Knockouts for Stucco and Surface Units Catalog Numbers— CMBB150BTS, CMBB200BTS, CMBP200BTS, CMBE24L125BTS, CMB24L125BTS, CMBE24L200BTS, CMBEB200BTS, CMBEB150BTS, CMBE88B150BTS, CMBP200BTS, CMBE88B200BTS, MBE24L125BTS, MBE24L200BTS, MBE48B150BTS, MBE48B200BTS, MBE88B200BTS, MBEB200BTS, MBE1224B100BTS, MBE1224B125BTS, CMB88B150BTS, CMB88B200BTS and MB48B200BTS 63b. 5 5 5 Bottom Endwall Knockout Size Dimensions in Inches (mm) 7 0.50, 0.75 (12.7, 19.1) 4 0.50, 0.75, 1.00 (12.7, 19.1, 25.4) 1 1.00, 1.25, 1.50, 2.00 (25.4, 31.8, 38.1, 50.8) 1 1.25, 1.50, 2.00, 2.50, 3.00 (31.8, 38.1, 50.8, 63.5, 76.2) 1 Notes 1 For details regarding quantities, please contact the Technical Resource Center (TRC) at 1-877-ETN-CARE. 2 Use when DS H1 Type 1, 1.25 and 1.50-inch hubs are needed. 3 RH hubs are to be used for Top Endwall (Stucco) endwalls. 5-5/16 (134.9) 5 Top Surface 5 5 4-15/16 (125.4) 5 Bottom 5 5 5 5 V1-T5-70 Quantity 0.50 (12.7) 5 5 Quantity Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Meter Breakers 5.9 Approximate Dimensions in Inches (mm) Knockouts for Stucco and Surface Units Catalog Number— MMBE2040B200TF 64a. Keyhole Knockouts on Sides for Stucco Units Only. Knockouts for Stucco and Surface Units Catalog Numbers— MBE1224B100TS, MBE1224B125TS, MBE816P200TS, MBE816P200TSCU, MBE2040B200TS, CMB1212P200BTS, CMB1212P200BTSD, CMB1212B200BTS, MB1212L200BTS and CMB1212L200BTS 64b. 5 5 5 3.50 (88.9) 5 5.31 (134.9) 5 5 Top Stucco 5 Top Surface 5 4.94 (125.4) 5 4.94 (125.4) 5 Bottom 5 Bottom Top Endwall (Surface) Hub Provision Catalog Number Quantity DS100H2 1 DS125H2 1 DS150H2 1 DS200H2 1 DS250H2 1 DS300H2 1 DS900AP 5 (Adapter Plate) 2 1 Knockout Size Dimensions in Inches (mm) Quantity 0.50 (12.7) 7 0.50, 0.75 (12.7, 19.1) 4 0.50, 0.75, 1.00 (12.7, 19.1, 25.4) 1 1.00, 1.25, 1.50, 2.00 (25.4, 31.8, 38.1, 50.8) 1 1.25, 1.50, 2.00, 2.50, 3.00 (31.8, 38.1, 50.8, 63.5, 76.2) 1 1 1.00, 1.25, 1.50 (25.4, 31.8, 38.1) 1 0.50, 0.75, 1.00 (12.7, 19.1, 25.4) 1 0.50, 0.75 (12.7, 19.1) 3 0.50 (12.7) 3 5 5 Quantity 1.25, 1.50, 2.00, 2.50 (31.8, 38.1, 50.8, 63.5) 5 5 Notes 1 For details regarding quantities, please contact the Technical Resource Center (TRC) at 1-877-ETN-CARE. 2 Use when DS H1 Type 1, 1.25 and 1.50-inch hubs are needed. 3 RH hubs are to be used for Top Endwall (Stucco) endwalls. Top Endwall (Stucco) 3 Knockout Size Dimensions in Inches (mm) 5 Bottom Endwall 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-71 5.9 5 5 5 Metering Products Meter Breakers Approximate Dimensions in Inches (mm) Knockouts for Stucco and Surface Units 3.44 (87.3) 5 5 Top Flush MBE4040B200BTF 5 5 5 5.31 (134.9) 5.31 (134.9) 5 Top Surface 5 Top Surface 2-1/2-inch Hub 5 5 4.94 (125.4) 4.94 (125.4) 5 5 5 5 5 Bottom Bottom CMBE4242B200BTS MBE4040B200BTS MBE4040B200BSH Bottom Endwall Top Endwall (Surface) Hub Provision Catalog Number Quantity Knockout Size Dimensions in Inches (mm) Quantity DS100H2 1 0.50, 0.75 (12.7, 19.1) 6 5 DS125H2 1 0.50, 0.75, 1, 1.25 (12.7, 19.1, 25.4, 31.8) 2 1 5 DS150H2 1.00, 1.25, 1.50, 2.00, 2.50 (25.4, 31.8, 38.1, 50.8, 63.5) 1 DS200H2 1 1.00, 1.25, 1.50, 2.00, 2.50, 3.00 (25.4, 31.8, 38.1, 50.8, 63.5, 76.2) 1 5 DS250H2 1 DS300H2 1 5 DS900AP (Adapter Plate) 2 1 5 Top Endwall (Stucco) 3 5 Knockout Size Dimensions in Inches (mm) Quantity 5 1.25, 1.50, 2.00, 2.50 (31.8, 38.1, 50.8, 63.5) 2 0.50, 0.75 (12.7, 19.1) 3 5 Notes 1 For details regarding quantities, please contact the Technical Resource Center (TRC) at 1-877-ETN-CARE. 2 Use when DS H1 Type 1, 1.25 and 1.50-inch hubs are needed. 3 RH hubs are to be used for Top Endwall (Stucco) endwalls. 5 5 5 5 5 V1-T5-72 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Meter Breakers 5.9 Approximate Dimensions in Inches (mm) Knockout Configurations and Dimensions for Catalog Numbers MBER48B200BTS and CMBER88B200BTS 66a. Semi-Flush Stucco Unit Knockout Configurations and Dimensions for MBE2040B200BTS, MBE2040B225BTS, MBE2040B200BTF and MBE2040B225BTF 66d. 5 5 5 5 5-5/16" 5 Top Surface 5 5 5 4-15/16" 5 5 Bottom End Mounting Surface Knockout Configurations and Dimensions for Catalog Numbers CMBXP200BTS, CMBXB200BTS, CMBX1212P200BTS and CMBX3242P200BTS, CMBX3242B200BTS, CMBX1212B200BTS 66b. 5 Knockout Configurations and Dimensions for Catalog Numbers MBT48B125BTS, MBT48B150BTS, MBT48B200BTS and MBT48P200BTS 66e. 5 5 5 5 5-5/16" 5 5 Top Surface 5 5 4-15/16" 5 5 Bottom 5 5 Surface Unit Knockout Configurations and Dimensions for MBE2040B200BTS, MBE2040B225BTS, MBE2040B200BTF and MBE2040B225BTF 66c. 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-73 5.9 5 5 5 5 Metering Products Meter Breakers Approximate Dimensions in Inches (mm) Knockouts for Non-EUSERC Units Catalog Numbers— MBB150BTS, MBB200BTS, MBP200BTS, MB816P200BTS, MB816P200BTSCU, MB816P200BTSD, MB816B200BTS, MB816B200BTSCU, MB2040P200BTS, MB2040B200BTS, MBP200BTSD, MBP200SD, MB816P200STD, MB2040B150SD, MB2040B200SD and MB2040P200SD 67a. Knockouts for Non-EUSERC Units Catalog Numbers— CMB2424B200BTS, MBB150BTSCR, MBB200BTSCR, MBB150BTSC, MBB200BTSC and CMB2436B200BTS 67c. 5 5 5.31 (134.9) 5.31 (134.9) 5 5 Top Surface (Catalog Numbers with SC and SCR Suffix Only) Top Surface 5 5 5 4.94 (125.4) 4.94 (125.4) 5 Bottom Bottom 5 Top Endwall (Surface) 5 Hub Provision Catalog Number Bottom Endwall Quantity Knockout Size Dimensions in Inches (mm) Quantity DS100H2 1 0.31 (7.9) 3 DS125H2 1 0.50 (12.7) 3 DS150H2 1 0.50, 0.75 (12.7, 19.1) 2 5 DS200H2 1 0.75, 1.00 (12.7, 25.4) 1 DS250H2 1 1.25, 1.50, 2.00, 2.50 (19.1, 38.1, 50.8, 63.5) 2 5 DS300H2 1 1.50, 2.00, 2.50, 3.00 (38.1, 50.8, 63.5, 76.2) 1 5 5 5 5 DS900AP (Adapter Plate) 1 2 Knockouts for Non-EUSERC Units Catalog Number— CHMMB100BTS 67b. 5 5 5 Knockouts for Non-EUSERC Units Catalog Numbers— CHMMB150BTS and CHMMB200BTS 67d. 4.94 (125.4) 4.94 (125.4) Bottom 5 Bottom Bottom Endwall 5 Bottom Endwall Knockout Size Dimensions in Inches (mm) Quantity 5 Knockout Size Dimensions in Inches (mm) Quantity 0.31 (7.9) 1 5 0.31 (7.9) 1 5 0.50 (12.7) 1 0.50, 0.75, 1.00, 1.25, 1.50, 2.00, 2.50 (12.7, 19.1, 25.4, 31.8, 38.1, 50.8, 63.5) 2 1,00, 1.25, 1.50, 2.00, 2.50 (25.4, 31.8, 38.1, 50.8, 63.5) 1 5 5 V1-T5-74 0.50 (12.7) 1 0.50, 0.75, 1.00, 1.25, 1.50, 2.00, 2.50 (12.7, 19.1, 25.4, 31.8, 38.1, 50.8, 63.5) 2 1.00, 1.25, 1.50, 2.00, 2.50, 3.00 (25.4, 31.8, 38.1, 50.8, 63.5, 76.2) 1 Notes 1 For details regarding quantities, please contact the Technical Resource Center (TRC) at 1-877-ETN-CARE. 2 Use when DS H1 Type 1, 1.25 and 1.50-inch hubs are needed. Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Meter Breakers 5.9 Contents House Panels Description Page Residential Meter Breakers . . . . . . . . . . . . . . . . . . Non-EUSERC Combination Service Entrance Devices 100–200A Styles . . . . . . . . . . . . . . . . . . Meets EUSERC Requirements Service Entrance Devices 100–225A . . . . . . . . . . . . . . . . . . . . . . . West Coast All-In-One Design. . . . . . . . . . . . . . . . Mechanical Interlock Cover . . . . . . . . . . . . . . . . . . House Panels Commercial Safety Sockets. . . . . . . . . . . . . . . . . . CH Style Renovation Solutions . . . . . . . . . . . . . . . Aluminum Meter Breakers . . . . . . . . . . . . . . . . . . 5 V1-T5-37 5 V1-T5-39 5 V1-T5-48 V1-T5-59 V1-T5-65 V1-T5-83 V1-T5-86 V1-T5-87 5 5 5 5 5 5 5 5 House Panels Product Description Application Description Eaton’s House Panels offer a faster, easier and safer installation.These 400A units are ideal for larger homes in North America that require meter breakers. Available in both CH and BR styles, these service entrance devices consist of a meter socket and a distribution section. In response to contractor feedback, these panels have been redesigned with a focus on flexibility, simplified wiring, and an overall ease of installation. All units come standard with a 22 kAIC main breaker.The load conductors can exit the top, bottom, side or back for greater application and installation flexibility. Additionally, Eaton’s House Panels can be used for apartments, condominiums, clubhouses or common areas. Features, Benefits and Functions ● ● ● ● ● ● NEMA 3R rainproof Rated for service entrance equipment Lever bypass socket available on certain catalog numbers Pin type door hinges Socket to distribution section is connected via insulated cable for safety Second main space can accept 100–200A BW, CSR or CSR breakers Standards and Certifications ● ● Ring style units meet EUSERC requirements UL listed 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-75 5.9 5 5 Metering Products Meter Breakers Product Selection House Panels 400A “House Panels” 5 5 Ampere Rating 5 Security 1 Bypass 2 Main Breaker Optional Secondary Main Breaker (Not Included) Service Type kAIC Dist. 300 Ringless Lever CSR2150 BW/CSR OH/UG 22 8/16 5 300 Ringless Lever CSR2150 BW/CSR UG 22 None 5 400 Ring None CSH2200N CSR UG 22 400 Ring None CSH2200N CSR UG 22 5 400 Ring Manual CSR2200 BRH/CSR UG 400 Ring Manual CSR2200 BRH/CSR 5 400 Ringless None DK2400 400 Ringless None CSR2200 5 400 Ring None DK2400 None UG 5 400 Ring None CSR2200 BRH/CSR UG 400 Ring None DK2400 None UG 5 400 Ring None CSR220 BRH/CSR UG 400 Ring Manual CSR2200 BRH/CSR UG 5 400 Ring None CSR2200 BRH/CSR 400 Ringless Lever CSH2200N CSR Line Side Main Lugs and Neutral (Lugs Not Included) Lug landings for compression SemiFlush Catalog Number 3 Surface Catalog Number — HP816P400BSL — HPC30SHL 32/42 — CG403242SH 12/12 — CG1212P400BS 5 22 None — HP40SHA 8 UG 22 40/40 — HP404040SHA 68 None UG 22 24/40 — HP402440B 7 BRH/CSR UG 22 24/40 — HP402440SBH 78 22 None — HP40 22 None — HP40SH 8 22 24/42 — HP402442 22 40/40 HP404040SHF HP404040SH 8 22 40/40 HP404040SHFA 6 — UG 22 8/16 — HP816P400BS 58 UG 22 12/12 — CG1212P400BSL 5 5 400 Ringless Lever CSH2200N CSR UG 22 42/42 — CG404242SHL 5 400 Ringless Lever CSR2200 BRH/CSR UG 22 None — HP40SHL 8 400 Ringless Lever CSR2200 BRH/CSR OH/UG 22 None — HPC40SHL 8 5 400 Ringless Lever CSR2200 BRH/CSR UG 22 40/40 — HP404040SHL 8 400 Ringless Lever CSR2200 BRH/CSR UG 22 8/16 — HP816P400BSL 58 5 400 Ringless Lever CSR2200 BRH/CSR OH/UG 22 4/6 — HPC4046SHLG 9 400 Ringless Lever CSR2200 BRH/CSR OH/UG 22 4/6 — HPC4046SHLX j 5 Notes 1 Confirm security type for individual EUSERC utility requirements. 2 Included in all of the following devices. 3 If unit needs to be semi-flush, order accessory item catalog number HPPR to convert all surface mounting devices to semi-flush mounting. 4 Secondary sub-main installed in panel. 5 Feed-through lugs included. 6 Includes manual bypass and additional ground lug to meet Nevada Power requirements. 7 Bolt-on meter socket. 8 For 10 kAIC, use BR or BW breakers as secondary main. 9 Georgia Power approved. j Xcel approved. 5 5 5 5 5 5 5 5 5 5 5 5 V1-T5-76 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Meter Breakers 5.9 Accessories ● ● ● ● 5 Top-feed gutter kit to ease top-fed installation Re-engineered, adjustable flush mount kit for a cleaner installation 100A second main breaker kit New 750 kcmil box type lug kit 5 5 5 5 5 Accessories HP40TFKIT Description Catalog Number Top feed kit to convert surface mount house panel for overhead service HP40TFKIT 5 5 5 5 5 5 5 HPBLK750 750 kcmil lug kit 5 HPBLK750 5 HPBPK Manual bypass kit 5 HPBPK 5 5 HP2NDMNKIT Flushmount kit HPPR 100A 2nd main kit (Type BR branch) HP2NDMNKIT 100A 2nd main kit (Type CH branch) CH2NDMNKIT 5th jaw for lever bypass house panels ARP00326CH Locates 3-inch (only) incoming conduit to back of can by utilizing the 4-inch knockout useful in semi-flush applications HP40HUBPLATE 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-77 5.9 Metering Products Meter Breakers 5 Wiring Diagrams 5 Type CH Style House Panels 5 Type CH Wiring—Catalog Number CG403242SH 5 5 A N 400 AMPERES (320 AMPERES CONTINUOUS) 1 2 3 4 5 6 7 8 B LINE 5 9 10 11 12 13 14 15 16 18 20 21 22 24 26 28 30 32 34 36 38 40 42 17 5 19 23 25 27 29 31 33 35 37 39 41 5 5 FACTORY/FIELD INSTALLED 100 A MAXIMUM SERVICE DISCONNECT TYPE CH OPTIONAL 200 A MAXIMUM SERVICE DISCONNECT TYPE BW OR CSR AMPERES (CONTINUOUS) EQUIPMENT GROUNDING TERMINALS A N B LINE 5 A N LINE B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 17 16 18 19 20 5 21 22 23 24 25 26 5 27 29 28 31 32 33 34 35 36 37 38 39 40 41 42 5 5 5 5 30 7 8 9 10 11 12 FACTORY/FIELD INSTALLED 200 A MAXIMUM SERVICE DISCONNECT FACTORY/FIELD INSTALLED 100 A MAXIMUM SERVICE DISCONNECT TYPE CH 400 AMPERES (320 AMPERES CONTINUOUS) A N B LINE 1 3 5 7 9 11 100 A MAX. SERVICE DISCONNECT TYPE CH 2 4 6 8 10 12 BONDED NEUTRAL EQUIPMENT GROUNDING TERMINALS BONDED NEUTRAL OPTIONAL 200 A MAX. SERVICE DISCONNECT TYPE CSR OPTIONAL 200 A MAXIMUM SERVICE DISCONNECT TYPE BW OR CSR Type CH Wiring Diagram Key #14-6 AWG #14-1/0 AWG 1/0 – 300 kcmil #4 AWG – 300 kcmil 5 5 5 5 5 5 V1-T5-78 6 Type CH Wiring—Catalog Number CG1212P400BSL FACTORY INSTALLED 200 A SERVICE DISCONNECT TYPE CSR 400 AMPERES (320 AMPERES CONTINUOUS) 5 2 4 5 BONDED NEUTRAL (OPTIONAL) 5 1 3 BONDED NEUTRAL Type CH Wiring—Catalog Number CG404242SHL 5 5 FACTORY/FIELD INSTALLED 200 A MAXIMUM SERVICE DISCONNECT TYPE CSR FACTORY INSTALLED 200 A SERVICE DISCONNECT 5 5 OPTIONAL 200 A MAX. SERVICE DISCONNECT TYPE CSR 100 A MAX. SERVICE DISCONNECT TYPE CH (OPTIONAL) 5 5 Type CH Wiring—Catalog Number CG1212P400BS Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Meter Breakers 5.9 Type BR Style House Panels 5 Type BR Wiring—Catalog Number HP40 F ACTOR Y INSTALLED 400 A SER VICE DISCONNECT TYPE DK A N B 5 100 A MAX. SERVICE DISCONNECT 1 3 5 7 9 11 13 15 LINE N (OPTIONAL) 200 A MAX. SERVICE DISCONNECT TYPE BW OR CSR FACTORY INSTALLED 200 A MAX. SERVICE DISCONNECT TYPE CSR 400 AMPS (320 AMPS CONTINUOUS) 400 AMPERES (320 AMPERES CONTINUOUS) A 5 Type BR Wiring—Catalog Number HP816P400BS 5 2 4 6 8 10 EQUIPMENT 12 GROUNDING 14 TERMINALS 16 5 5 BONDED NEUTRAL B 5 LINE BONDED NEUTRAL 5 5 Type BR Wiring—Catalog Number HP402440B 5 Type BR Wiring—Catalog Number HP402440SBH FACTORY INSTALLED 400 A SERVICE DISCONNECT TYPE DK 400 AMPS (320 AMPS CONTINUOUS) A N B LINE (OPTIONAL) 1 2 3 4 5 6 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 N B LINE BONDED NEUTRAL 5 100 A MAX. SERVICE DISCONNECT TYPE BRH OR BR 400 AMPS (320 AMPS CONTINUOUS) A 5 FACTORY/FIELD INSTALLED 200 A MAX. SERVICE DISCONNECT TYPE CSR OR BW FACTORY INSTALLED 200 A SERVICE DISCONNECT TYPE CSR 1 2 3 4 5 6 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 5 5 BONDED NEUTRAL 5 5 5 Type BR Wiring—Catalog Number HP404040SH 5 Type BR Wiring Diagram Key 5 #14-6 AWG (OPTIONAL) FACTORY/FIELD INSTALLED 200 A MAXIMUM SERVICE DISCONNECT TYPE CSR OR BW FACTORY INSTALLED 200 A SERVICE DISCONNECT TYPE CSR 400 AMPERES 1 (320 AMPERES 3 CONTINUOUS) 5 A N LINE B 7 9 100 A MAXIMUM SERVICE DISCONNECT TYPE BRH OR BR 5 #14-1/0 AWG #6 AWG – 250 kcmil 5 #1 AWG – 300 kcmil 5 2 4 6 EQUIPMENT 8 GROUNDING TERMINALS 10 11 12 13 14 15 16 17 18 19 20 21 22 23 25 24 26 27 28 29 30 31 32 33 34 35 36 37 39 38 BONDED NEUTRAL 1/0 – 300 kcmil #4 AWG – 300 kcmil 5 #6 AWG – 300 kcmil 5 5 5 40 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-79 5.9 5 Meter Breakers Type BR Wiring—Catalog Number HP402442 5 FACTORY INSTALLED BY-PASS. 400 AMPERES (320 AMPERES CONTINUOUS) A N 1 B LINE 5 5 5 5 3 4 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 FACTORY INSTALLED 200 A SERVICE DISCONNECT TYPE CSR 400 AMPS (320 AMPS CONTINUOUS) B A LINE 1 2 3 BONDED NEUTRAL 5 7 4 9 10 11 12 N 14 5 17 16 18 19 20 21 22 5 25 26 27 28 29 30 31 32 5 33 34 35 36 37 38 39 40 23 BONDED NEUTRAL GROUNDING LUG 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 33 32 34 35 37 36 38 39 40 OPTIONAL 200 A MAX. SERVICE DISCONNECT TYPE CSR FACTORY/FIELD INSTALLED 200 A MAX. SERVICE DISCONNECT TYPE BW OR CSR 100 A MAX. SERVICE DISCONNECT TYPE BR OR BHR FACTORY INSTALLED 200 A MAX. SERVICE DISCONNECT 400 AMPS (320 AMPS CONTINUOUS) A N B LINE 100 A MAX. SERVICE DISCONNECT 1 3 5 7 9 11 13 15 2 4 6 8 10 12 14 16 24 Type BR Wiring Diagram Key #14-6 AWG (OPTIONAL) FACTORY/FIELD INSTALLED 200A MAX. SERVICE DISCONNECT TYPE CSR OR BW 100A MAX. SERVICE DISCONNECT TYPE BRH OR BR FACTORY INSTALLED 200 A SERVICE DISCONNECT TYPE CSR 400 AMPS (320 AMPS CONTINUOUS) #6 AWG – 250 kcmil #1 AWG – 300 kcmil 1/0 – 300 kcmil 1/3 – 300 kcmil 1 #4 AWG – 300 kcmil #6 AWG – 300 kcmil A N B LINE BONDED NEUTRAL Type BR Wiring—Catalog Number HP40SHL 5 FACTORY INSTALLED 200 A SERVICE DISCONNECT TYPE CSR 5 400 AMPS (320 AMPS CONTINUOUS) 5 (OPTIONAL) FACTORY/FIELD INSTALLED 200 A MAX. SERVICE DISCONNECT TYPE BW OR CSR 100 A MAX. SERVICE DISCONNECT TYPE BR OR BRH BONDED NEUTRAL A LINE B N 5 5 V1-T5-80 EQUIPMENT GROUNDING TERMINALS BONDED NEUTRAL #14-1/0 AWG 5 5 LINE 1 Type BR Wiring—Catalog Number HP40SH 5 5 9 B 8 15 5 6 EQUIPMENT 8 GROUNDING 10 TERMINALS 7 N 100 A MAX. SERVICE DISCONNECT TYPE BRH OR BR 6 13 5 4 (OPTIONAL) 5 5 2 3 5 2 A 1 Type BR Wiring—Catalog Number HP816P400BSL 5 5 FACTORY/FIELD INSTALLED 200 A MAX. SERVICE DISCONNECT TYPE CSR OR BW Type BR Wiring—Catalog Number HP404040SHL 5 5 (OPTIONAL) FACTORY INSTALLED 200 A SERVICE DISCONNECT TYPE CSR FACTORY INSTALLED 400 A SERVICE DISCONNECT TYPE DK 5 5 Type BR Wiring—Catalog Number HP404040SHA 400 AMPS (320 AMPS CONTINUOUS) 5 5 Metering Products Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Meter Breakers 5.9 Catalog Numbers HPC40SHL and HPC30SHL 5 5 N 400 Amps (320 Amps Continuous) 5 Bonded Neutral 5 (Optional) Factory/Field Installed 150 A Max. - HPC30SHL 200 A Max. - HPC40SHL Service Disconnect Type BW or CSR 5 (Optional) 100 A Max. Service Disconnect Type BR or BRH 5 5 5 Factory Installed 150 A or 200 A Service Disconnect Type CSR 5 5 5 Dimensions and Knockouts 5 Approximate Dimensions in Inches (mm) 5 Catalog Numbers HPC40SHL and HPC30SHL 5 5 5 5 5 5 5 5 5 5 Knockout Configurations and Dimensions for HPC40SHL and HPC30SHL 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-81 5.9 5 5 Metering Products Meter Breakers Approximate Dimensions in Inches (mm) House Panel Dimensions and Knockouts—For All House Panels Except Those With HPCPREFIX 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 V1-T5-82 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Meter Breakers 5.9 Contents Residential Meter Breakers Description Page Residential Meter Breakers. . . . . . . . . . . . . . . . . . Non-EUSERC Combination Service Entrance Devices 100–200A Styles . . . . . . . . . . . . . . . . . . Meets EUSERC Requirements Service Entrance Devices 100–225A . . . . . . . . . . . . . . . . . . . . . . . West Coast All-In-One Design. . . . . . . . . . . . . . . . Mechanical Interlock Cover . . . . . . . . . . . . . . . . . . House Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . Commercial Safety Sockets CH Style Renovation Solutions . . . . . . . . . . . . . . . Aluminum Meter Breakers . . . . . . . . . . . . . . . . . . 5 V1-T5-37 5 V1-T5-39 5 V1-T5-48 V1-T5-59 V1-T5-65 V1-T5-75 V1-T5-86 V1-T5-87 5 5 5 5 5 5 5 5 Commercial Safety Sockets Product Description A Commercial Safety Socket is service entrance equipment that consists of a commercial meter socket with a test block, and may come with or without a loadcenter type distribution section. 5 Features, Benefits and Functions Commercial Safety Sockets with No Secondary Feeder 5 Overhead Combination Units Underground Combination Units 5 5 5 Application Description Eaton’s Commercial Safety Sockets are typically used where a single meter socket or single meter socket with a distribution section are needed. These areas could include a commercial business, commercial office building, individual retail facilities and signs and street lighting. Commercial Safety Sockets are typically used in EUSERC utility regions. 5 5 5 5 ● ● ● ● ● ● ● Ring type continuous duty meter socket. 600 Vac maximum, single- or three-phase 100 and 200A units Bussed connection from meter socket to test block For use with self-contained watthour meter Conform with EUSERC standards NEMA 3R construction for indoor/outdoor applications Units can be individually mounted with provisions for hub kits and pole mounting ● ● ● ● ● ● NEMA 3R construction for indoor/outdoor applications T-fuse protection, 480 Vac maximum Line at top, load at bottom 100 and 200A units available up to 480 Vac maximum Circuit breaker protection to 480 Vac maximum in 10, 22, 42 and 100 kAIC ratings Factory-cabled connection from test block to line side of tenant main ● ● ● ● ● ● ● ● 100 and 200A units 480 Vac maximum NEMA 3R construction for indoor/outdoor applications Underground or overhead feed Provisions for selfcontained watthour meter Bussed connection from meter socket to test block Tenant main disconnects are available with circuit breakers up to 480 Vac maximum and T-fuse mains, 240 Vac maximum Load wires can exit top or bottom 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-83 5.9 Metering Products Meter Breakers 5 Product Selection 5 Overhead and Underground Combination Units and Individual Units 5 CH127TB Individual Safety Sockets—600V Maximum—No Secondary Feeder Devices Phase, Wire Maximum Interrupting Rating Wire Size Catalog Number OH/UG Single-phase, three-wire 1 #14–2/0 CH114TB 600 OH/UG Three-phase, three-wire 1 #14–2/0 CH115TB 7 600 OH/UG Three-phase, four-wire 1 #14–2/0 CH117TB 200 4 600 OH/UG Single-phase, three-wire 1 #6–250 kcmil CH124TB 200 5 600 OH/UG Three-phase, three-wire 1 #6–250 kcmil CH125TB 200 7 600 OH/UG Three-phase, four-wire 1 #6–250 kcmil CH127TB Ampere Rating No. of Jaws AC Voltage Service 125 4 600 125 5 5 125 5 5 5 5 5 Commercial Safety Sockets with Provision for Main Circuit Breaker 5 Ampere Rating No. of Jaws AC Voltage Service 5 125 4 240 125 7 125 5 5 5 5 5 Phase, Wire Feeder Circuit Breaker Maximum Interrupting Rating Wire Size Catalog Number OH Single-phase, three-wire Provision 2 4 #14–2/0 CH214MTBLB 208/120 OH Three-phase, four-wire Provision 2 4 #14–2/0 CH217MTBLB 4 240 UG Single-phase, three-wire Provision 2 4 #14–2/0 CHU214MTBLB 125 7 208/120 UG Three-phase, four-wire Provision 2 4 #14–2/0 CHU217MTBLB 200 4 120/240 OH Single-phase, three-wire Provision 3 5 #6–250 kcmil CH224MTBLB 3 5 200 7 208/120 OH Three-phase, four-wire Provision #6–250 kcmil CH227MTBLB 200 4 120/240 UG Single-phase, three-wire Provision 3 5 #6–250 kcmil CHU224MTBLB 200 7 208/120 UG Three-phase, four-wire Provision 3 5 #6–250 kcmil CHU227MTBLB Commercial Safety Sockets with Main Circuit Breaker Included 5 Phase, Wire Feeder Circuit Breaker Maximum Interrupting Rating Wire Size Catalog Number OH Three-phase, four-wire EHD3100 14 kA #14–2/0 CH217MTBM515 480/277 UG Three-phase, four-wire EHD3100 14 kA #14–2/0 CHU217MTBMS15 480/277 OH Three-phase, four-wire JD3200 25 kA #6–250 kcmil CH227MTBHMS15 480/277 UG Three-phase, four-wire JD3200 25 kA #6–250 kcmil CHU227MTBHMS15 Ampere Rating No. of Jaws AC Voltage Service 100 7 480/277 5 100 7 5 200 7 200 7 5 5 Notes 1 If being protected by a fuse, the interrupting rating of the unit is limited to the fuse AIC rating. If being protected by a single- or three-phase, 600V breaker, the AIC is 14 kA; by a maximum 400A, single-phase, 240V breaker, the AIC is 18 kA; by a maximum 200A, single- or three-phase, 240V breaker, the AIC is 18 kA; by a maximum 125A, single-phase, 240V breaker, the AIC is 22 kA. 2 Order plug-on Type BR, BRH or BRHH circuit breaker separately. 3 Order Type CC breaker or CCH breaker separately. 4 Type BR = 10 kA; Type BRH = 22 kA; Type BRHH = 42 kA. 5 Type CCV = 10 kA; Type CCVH = 25 kA. 5 5 5 5 5 5 5 5 5 V1-T5-84 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 5.9 Metering Products Meter Breakers Underground Combination Units and Safety Socket Accessories CHU227MTBP 5 Commercial Safety Sockets with T-Fuse Switch 5 Phase, Wire Feeder Circuit Breaker Maximum Interrupting Rating Wire Size 5 OH Single-phase, three-wire 200 kA #14–2/0 CH214MTBP OH Three-phase, four-wire 200 kA #14–2/0 CH217MTBP 5 Ampere Rating No. of Jaws AC Voltage Service 100 4 120/240 100 7 208/120 100 4 120/240 UG Single-phase, three-wire 200 kA #14–2/0 CHU214MTBP 100 7 208/120 UG Three-phase, four-wire 200 kA #14–2/0 CHU217MTBP 200 4 120/240 OH Single-phase, three-wire 200 kA #6–250 kcmil CH224MTBP 200 7 208/120 OH Three-phase, four-wire 200 kA #6–250 kcmil CH227MTBP 200 4 120/240 UG Single-phase, three-wire 200 kA #6–250 kcmil CHU224MTBP 200 7 208/120 UG Three-phase, four-wire 200 kA #6–250 kcmil CHU227MTBP 5 5 5 5 5 Hubs Description Carton Weight Lbs (kg) Catalog Number 5 Hub closure plate 3 (1.4) ARP00002CHB 1.00-inch (25.4 mm) hub 3 (1.4) ARP00003CH1 5 1.25-inch (31.8 mm) hub 3 (1.4) ARP00004CH12 1.50-inch (38.1 mm) hub 3 (1.4) ARP00005CH15 2.00-inch (50.8 mm) hub 3 (1.4) ARP00006CH2 2.50-inch (63.5 mm) hub 3 (1.4) ARP00007CH25 5 5 5 5 Jaws Description Part Number 5th jaw kit CH50371 5 5 Note Order Type CC or CHH breaker separately. 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-85 5.9 5 Metering Products Meter Breakers CH Style Renovation Solutions Contents Description 5 Page Residential Meter Breakers . . . . . . . . . . . . . . . . . Non-EUSERC Combination Service Entrance Devices 100–200A Styles. . . . . . . . . . . . . . . . . . Meets EUSERC Requirements Service Entrance Devices 100–225A . . . . . . . . . . . . . . . . . . . . . . . West Coast All-In-One Design . . . . . . . . . . . . . . . Mechanical Interlock Cover . . . . . . . . . . . . . . . . . . House Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . Commercial Safety Sockets . . . . . . . . . . . . . . . . . CH Style Renovation Solutions Aluminum Meter Breakers . . . . . . . . . . . . . . . . . . 5 5 5 5 5 5 5 5 5 CH Style Renovation Solutions 5 Product Description 5 5 ● ● 5 ● 5 ● ● 5 Ring style meter socket design Provisional main breaker or factory main breaker available Center top feed design Exit bottom or top design 100A, 125A or 200A ratings available 5 Product Selection 5 CH Style Retrofit Solutions 5 Description Catalog Number 100 CH, 22 circuit, provision, center top feed, exit top or bottom, flush, OH/UG CMBE22P100BTFR 125 CH, 22 circuit, provision, center top feed, exit top or bottom, surface, OH/UG CMBE22P125BTSR 5 125 CH, 22 circuit, provision, center top feed, exit top or bottom, flush, OH/UG CMBE22P125BTFR 200 CH, 32/42 circuit, 200A main breaker, center top feed, exit top or bottom, semi-flush, OH/UG CMBE3242B200BTS 5 200 CH, 32/42 circuit, 200A main breaker, center top feed, exit top or bottom, flush, OH/UG CMBE3242B200BTFR 5 Ampere Rating 5 5 5 5 5 5 5 V1-T5-86 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-37 V1-T5-39 V1-T5-48 V1-T5-59 V1-T5-65 V1-T5-75 V1-T5-83 V1-T5-87 Metering Products Meter Breakers 5.9 Contents Description Page Residential Meter Breakers . . . . . . . . . . . . . . . . . . Non-EUSERC Combination Service Entrance Devices 100–200A Styles . . . . . . . . . . . . . . . . . . Meets EUSERC Requirements Service Entrance Devices 100–225A . . . . . . . . . . . . . . . . . . . . . . . West Coast All-In-One Design. . . . . . . . . . . . . . . . Mechanical Interlock Cover . . . . . . . . . . . . . . . . . . House Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . Commercial Safety Sockets. . . . . . . . . . . . . . . . . . CH Style Renovation Solutions . . . . . . . . . . . . . . . Aluminum Meter Breakers 5 V1-T5-37 5 V1-T5-39 5 V1-T5-48 V1-T5-59 V1-T5-65 V1-T5-75 V1-T5-83 V1-T5-86 5 5 5 5 5 5 5 5 Aluminum Meter Breakers Product Description Features and Benefits Eaton’s Aluminum Meter Breaker enclosure and external cover offers excellent corrosion resistance in the harshest coastal environments. The meter breaker’s light weight and overhead/underground design offers flexibility and ease of installation. ● ● ● Overhead/underground design provides flexibility with wiring options Steel meter guides are standard, which provides a means of easy installation of the utility glass bulb meter into the meter’s jaws Main Lug Only design includes six two-pole breaker locations, which complies with National Electrical Code 225.33 (maximum number of disconnects) ● ● ● ● ● Distribution section accepts BR branch breakers Single-phase, three-wire 120/240 Vac applications Hub closure plate is provided, attached to the top of the device Optional fifth jaw can be applied to 3 o’clock or 9 o’clock meter socket position 10-year warranty ● ● For customer support, contact Eaton’s Technical Resource Center at 1-877-ETN-CARE For additional information or to place an order, contact your local Eaton representative or visit us at www.eaton.com 5 5 5 5 5 5 5 5 5 5 Catalog Number Selection 5 Meter Breakers 5 MB 12 12 L 200 BT S A 5 Material A = Aluminum Meter Breaker Type MB = 1-inch (25.4 mm) BR Type 5 Mounting S = Surface Spacing Number of spaces Poles Maximum number of poles 5 Main L = Lug 5 Breaker Feed BT = Bottom and top 5 Amperes Amperage of unit 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-87 5.10 5 Metering Products Group Metering Systems for Residential and Commercial Application Description 5 Systems for Residential and Commercial Applications Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type CCV 120/240V Tenant Main Circuit Breaker . Type CV 120/240V Tenant Main Circuit Breaker . . Meter Packs—1MP, 1MM and 3MM Main Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . Main Service Modules . . . . . . . . . . . . . . . . . . . . . Surge Metering. . . . . . . . . . . . . . . . . . . . . . . . . . . Residential Meter Stacks . . . . . . . . . . . . . . . . . . . 1MP, 1MM and 3MM Main Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . Phase Balanced Stack. . . . . . . . . . . . . . . . . . . . . . Commercial Meter Stack Modules . . . . . . . . . . . . 35MM, 37MM, 35SS and 37SS Main Tenant Circuit Breakers . . . . . . . . . . . . . . . 5 5 5 5 5 5 5 5 5 Systems for Residential and Commercial Applications 5 Product Description Application Description Group metering is a service entrance product line that consists of a main device and multiple meter sockets in one enclosure or several connected enclosures. Group metering allows the customer to install a multiple tenant-metering device in one location while providing a space and installation cost savings. Eaton’s Electrical Sector offers two group metering designs—Meter Packs and Gangable Metering. Meter Packs, also called All-in-Ones, consist of main lugs and up to six meter sockets in one enclosure. Meter Packs are supplied as one complete unit and the user cannot “add” additional meter sockets to the unit in the future. The most common application for Meter Packs is garden apartments, small condominiums and townhouses where six or less units are metered through one centrally located Meter Pack. 5 5 5 5 5 5 Contents 5 5 5 5 5 5 5 Gangable Metering (Main Service Modules and Meter Stacks) The second type of group metering is Gangable Metering, which consists of a Main Service Module used in conjunction with a Meter Stack to make a custom metering lineup. The Main Service Module can be main lug, main circuit breaker, main fusible switch or bolted pressure switch. The Meter Stack is offered with various meter sockets and bus ratings. This type of custom lineup allows the owner to add/remove meter sockets and main devices to meet future need. Gangable Metering is often used in large condominiums, strip malls and light commercial applications where more than six units are metered, or there will be a future need to add more units. 5 5 5 5 5 V1-T5-88 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Page V1-T5-90 V1-T5-95 V1-T5-96 V1-T5-98 V1-T5-101 V1-T5-115 V1-T5-116 V1-T5-125 V1-T5-126 V1-T5-127 V1-T5-134 5.10 Metering Products Group Metering Features, Benefits and Functions Clip-Tight™ Socket 5 Field Phase Balancing Lever Bypass Main Tenant Breaker Cover 5 5 5 5 5 5 Clip-Tight Socket Field Phase Balancing Lever Bypass Eaton’s series of 1MP, 1MM, 3MM metering devices incorporate the only socket base in the industry without fasteners. This component uses jaws on both sides of a thermoplastic polyester glass fiber reinforced (PBT) base, eliminating the need for self-tapping screw connections to vertical busbars. Due to popular incoming three-phase voltage systems and single-phase outgoing loads, installers have the option to field phase balance on the individual stack (A-B, B-C, A-C). This feature eliminates the chance of installing an incorrectly phased device due to its versatility. Due to commercial requirements, Eaton offers a lever bypass (as standard) on all 35MM and 37MM devices. Each socket base consists of a lever bypass, which also releases the jaws (when lever is engaged in bypass position), enabling utility company mechanics to easily remove and/or insert utility meter. One-Piece Vertical Busbar Horn and Manual Bypass Test Bypass Disconnects 5 5 5 Main Tenant Breaker Cover Each tenant circuit breaker is protected by a lockable raintight cover that secures the breaker against unauthorized operation. The tenant breaker cover is a high impact plastic to resist wear, rusting and corrosion. 5 5 5 5 5 Mounting Features 5 5 5 5 5 Horn and Manual Bypass One-Piece Vertical Busbar Eaton’s series of 1MP, 1MM, 3MM meter stacks embody a one-piece busbar construction to each socket, as well as a one-piece cross bus to each tenant main. Because the Eaton design uses the Clip-Tight meter socket and does not have busbar joints, the chance of hot spots occurring is virtually eliminated. With an increasing demand for uninterrupted power, Eaton’s series of 1MP, 1MM and 3MM meter sockets offer horn (ringless style) and manual (ring style) fieldinstallable bypass accessories. These accessories provide uninterrupted tenant service if a meter is pulled for inspection or replacement. Mounting Features A standard mounting rail and factory-installed swing away feet speed up and simplify installation. Test Bypass Disconnects Eaton also provides commercial meter stacks with EUSERC required testbypass disconnects (35SS and 37SS). This bypass is used in the same applications as the lever bypass and it is required by EUSERC utilities. Standards and Certifications ● UL listed 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-89 5.10 5 Metering Products Group Metering Contents Meter Pack Description 5 Systems for Residential and Commercial Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . Meter Packs Type CCV 120/240V Tenant Main Circuit Breaker . Type CV 120/240V Tenant Main Circuit Breaker . . Meter Packs—1MP, 1MM and 3MM Main Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . Main Service Modules . . . . . . . . . . . . . . . . . . . . . Surge Metering. . . . . . . . . . . . . . . . . . . . . . . . . . . Residential Meter Stacks . . . . . . . . . . . . . . . . . . . 1MP, 1MM and 3MM Main Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . Phase Balanced Stack. . . . . . . . . . . . . . . . . . . . . . Commercial Meter Stack Modules . . . . . . . . . . . . 35MM, 37MM, 35SS and 37SS Main Tenant Circuit Breakers . . . . . . . . . . . . . . . 5 5 5 5 5 5 5 5 5 Meter Packs 5 Product Overview 5 ● 5 5 ● 5 5 ● 5 5 5 5 5 5 5 ● ● ● Eaton’s 1MP units are self-contained (main terminal box included) for installations requiring up to six meter socket positions in a single enclosure Units are not gangable with any other metering device Approved by major power companies, UL listed, suitable as service equipment and meet the service and electrical requirements of EUSERC and CECHA Series rating up to 100 kAIC All ringless cover devices include fifth jaw as standard Ring type devices do not include fifth jaw as standard. Order 1MM5JK if needed ● ● ● ● ● ● ● ● Bondable neutral 120/240 Vac, single-phase three-wire metering device Up to 600A maximum horizontal bus rating Incoming lugs not included (phase A, phase B and neutral) Indoor/outdoor construction Provision for two-pole breaker (plug-on type for 125A sockets and bolt-on type for 200A sockets)— circuit breakers not included Underground incoming feed Aluminum or copper bus 5 5 5 5 5 5 V1-T5-90 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Page V1-T5-88 V1-T5-95 V1-T5-96 V1-T5-98 V1-T5-101 V1-T5-115 V1-T5-116 V1-T5-125 V1-T5-126 V1-T5-127 V1-T5-134 Metering Products Group Metering 5.10 Catalog Number Selection 5 1 M P 4 12 4 R C Single-Phase Type of Metering MP = Meter pack Number of Meters 2, 3, 4, 5 or 6 Blank = Accessory Ampere Rating 12 = 125A 20 = 200A Blank = Accessory 5 5 Bus Material C = Copper bus Blank = Aluminum bus 5 5 Security or Accessory Code R= Ring RRL = Ringless RRLB = Ringless with horn bypass LK = Lug kit (accessory) SC = Crimp lug landing pad kit (accessory) 5 5 5 Bus Ampere Rating 2 = 200A 4 = 400A 6 = 600A Blank = Accessory 5 5 When Ordering: 1. Determine catalog number of the basic device. 5 2. Include Lug Kit for incoming section. See Page V1-T5-94. 3. Find quantity and catalog numbers for tenant circuit breakers. (Order one breaker per socket.) See Page V1-T5-94. 5 4. Select required accessories. See Page V1-T5-136. 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-91 5.10 Metering Products Group Metering 5 Product Selection 5 Meter Packs 5 Aluminum Bus—Main Lugs Not Included—See Page V1-T5-94 5 Socket Ampere Rating 5 5 Number of Meter Sockets Bus Ampere Rating Main Tenant Breaker Type (See Page V1-T5-94) Catalog Number Semi-Flush Flange Kit Catalog Number Ring Style Meter Socket Covers 1 125 2 24 200 125 2 3 400 2 Plug-on type BR2_ BRH2_ BRHH2_ 1MP2122R 58 1MPSFK1 1MP3124R 6 1MPSFK2 6 1MPSFK2 5 125 4 400 125 2 54 600 1MP5126R 6 1MPSFK3 5 125 2 64 600 1MP6126R 6 1MPSFK3 5 200 3 2 400 1MP2204R 6 1MPSFK4 200 3 3 600 1MP3206R 6 1MPSFK5 5 200 3 4 600 1MP4206R 6 1MPSFK5 200 3 5 600 1MP5206R 6 1MPSFK6 5 200 3 6 600 1MP6206R 6 1MPSFK6 1MP2122RRL 58 1MPSFK1 1MP3124RRL 6 1MPSFK2 1MP4124RRL 6 1MPSFK2 Bolt-on type CCV2_X CCVH2_X CVS2_XMM CV2_XMM CVH2_XMM 1MP4124R Ringless Style Meter Socket Covers 7 5 125 2 200 5 125 3 400 125 4 400 5 125 5 600 1MP5126RRL 6 1MPSFK3 125 6 600 1MP6126RRL 6 1MPSFK3 5 200 2 400 1MP2204RRL 6 1MPSFK4 200 3 600 1MP3206RRL 6 1MPSFK5 6 1MPSFK5 1MP5206RRL 6 1MPSFK6 1MP6206RRL 6 1MPSFK6 1MP2122RRLB 58 1MPSFK1 1MP3124RRLB 69 1MPSFK2 1MP4124RRLB 69 1MPSFK2 5 200 4 600 5 200 5 600 200 6 600 5 Ringless Style Covers with Horn Bypass 7 Plug-on type BR2_ BRH2_ BRHH2_ Bolt-on type CCV2_X CCVH2_X CVS2_XMM CV2_XMM CVH2_XMM 125 2 200 5 125 3 400 5 125 4 400 125 5 600 1MP5126RRLB 69 1MPSFK3 69 1MPSFK3 1MP2204RRLB 69 1MPSFK4 1MP3206RRLB 69 1MPSFK5 1MP4206RRLB 69 1MPSFK5 1MP5206RRLB 69 1MPSFK6 1MP6206RRLB 69 1MPSFK6 5 125 6 600 200 2 400 5 200 3 600 200 4 600 200 5 600 200 6 600 5 5 5 5 5 5 5 Plug-on type BR2_ BRH2_ BRHH2_ 1MP4206RRL 1MP6126RRLB Bolt-on type CCV2_X CCVH2_X CVS2_XMM CV2_XMM CVH2_XMM Notes 1 Ring Style Meter Packs do not come with fifth jaw. Order 1MM5JK if needed. 2 To change in field from ring to ringless—order 1MMRC125. 3 To change in field from ring to ringless—order 1MMRC200. 4 To change from ring to ringless covers, the top socket only in 2, 5 and 6 socket designs—order 1MMRC125T. Top socket only. 5 Main lugs included. #6–300 kcmil. (Optional lugs are not available.) 6 For overhead use, order DS_H2 type hub. 7 Fifth jaw factory installed at 9 o’clock position. 8 For overhead use, order DS type hub. 9 To order with raceway provision in bottom endwall, add “T” suffix to the catalog number. Trough accessory catalog number is 1008934CH. See Page V1-T5-94 for Main Lug Kit selection and Wire Sizes. 5 V1-T5-92 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Group Metering 5.10 Copper Bus—Main Lugs Not Included—See Page V1-T5-94 Socket Ampere Rating Number of Meter Sockets Bus Ampere Rating Main Tenant Breaker Type (See Page V1-T5-94) 5 Semi-Flush Flange Kit Catalog Number Catalog Number 5 Ring Style Meter Socket Covers 1 125 2 24 1MP2122RC 6 1MPSFK1 7 1MPSFK2 1MP4124RC 7 1MPSFK2 600 1MP5126RC 7 1MPSFK3 600 1MP6126RC 7 1MPSFK3 200 2 3 400 125 2 4 400 125 2 54 125 2 64 200 3 2 400 200 3 3 600 200 3 4 600 125 3 5 600 200 3 6 600 200 Plug-on type BR2_ BRH2_ BRHH2_ Bolt-on type CCV2_X CCVH2_X CVS2_XMM CV2_XMM CVH2_XMM 1MP3124RC 1MP2204RC 7 1MPSFK4 1MP3206RC 7 1MPSFK5 1MP4206RC 7 1MPSFK5 7 1MPSFK6 1MP6206RC 7 1MPSFK6 1MP2122RRLC 7 1MPSFK1 1MP3124RRLC 7 1MPSFK2 1MP4124RRLC 7 1MPSFK2 1MP5126RRLC 7 1MPSFK3 1MP6126RRLC 7 1MPSFK3 1MP2204RRLC 7 1MPSFK4 1MP5206RC 5 5 5 5 5 5 5 Ringless Style Meter Socket Covers 5 125 2 200 125 3 400 125 4 400 125 5 600 125 6 600 200 2 400 200 3 600 200 4 600 200 5 600 200 6 Plug-on type BR2_ BRH2_ BRHH2_ Bolt-on type CCV2_X CCVH2_X CVS2_XMM CV2_XMM CVH2_XMM 600 5 5 5 5 1MP3206RRLC 7 1MPSFK5 1MP4206RRLC 7 1MPSFK5 1MP5206RRLC 7 1MPSFK6 7 1MPSFK6 5 7 1MPSFK1 1MP3124RRLBC 7 1MPSFK2 5 1MP4124RRLBC 7 1MPSFK2 1MP5126RRLBC 7 1MPSFK3 1MP6126RRLBC 7 1MPSFK3 1MP2204RRLBC 7 1MPSFK4 1MP3206RRLBC 7 1MPSFK5 1MP4206RRLBC 7 1MPSFK5 1MP5206RRLBC 7 1MPSFK6 1MP6206RRLBC 7 1MPSFK6 1MP6206RRLC 5 Ringless Style Covers with Horn Bypass 5 125 2 200 125 3 400 125 4 400 125 5 600 125 6 600 200 2 400 200 3 600 200 4 600 200 5 600 200 6 600 Plug-on type BR2_ BRH2_ BRHH2_ Bolt-on type CCV2_X CCVH2_X CVS2_XMM CV2_XMM CVH2_XMM 1MP2122RRLBC 5 5 5 5 5 5 Notes 1 Ring Style Meter Packs do not come with fifth jaw. Order 1MM5JK if needed. 2 To change in field from ring to ringless—order 1MMRC125. 3 To change in field from ring to ringless—order 1MMRC200. 4 To change in field from ring to ringless covers, the top socket only in 5 to 6 socket design—order 1MMRC125T. Top socket only—other sockets see 2. 5 Fifth jaw factory installed at 9 o’clock position. 6 For overhead use, order DS_H2 type hub. 7 For overhead use, order DS_MH type hub. 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-93 5.10 5 1MPLK3 Metering Products Group Metering Main Lug Selection—Field-Installed Lugs for 400 or 600A Main Bus 5 Line Lug and Wire Sizes Order Separately and Field Install Line Lug Kit Catalog Number Order Three Kits (For Two Lines and Neutral) 5 (1) #6–600 kcmil or (2) 2/0–250 kcmil 1MPLK1 (2) 250–500 kcmil 1MPLK3 5 (3) #4–300 kcmil 1MPLK4 1 (1) 750 kcmil 1MPLK2 2 5 Crimp lug landing pad 250–750 kcmil 1MPSC1 1 5 Wire Sizes—Neutral and Ground Lugs 5 Description Wire Size, Al/Cu Catalog Number 5 Neutral—125A meter pack #6–2/0 — Neutral—200A meter pack #1/0–300 kcmil — 5 Equipment ground bar—125A meter pack #14–#2 — Equipment ground bar—200A meter pack #14–2/0 — 5 Optional ground bar #6–2/0 1MMGBK 5 Notes 1 This kit comes with three pads for two lines and neutral. Each pad will accept one or two crimp lugs. Cannot be used on 1MP2122R, RL, RC and RLB EUSERC underground termination. 2 This lug is not UL listed. 5 Each stack includes a neutral and ground bar. If an extra ground bar is needed, order 1MMGBK. 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 V1-T5-94 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Group Metering 5.10 Contents Type CCV Tenant Main Circuit Breaker Description Page Systems for Residential and Commercial Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type CCV 120/240V Tenant Main Circuit Breaker Type CV 120/240V Tenant Main Circuit Breaker . . Meter Packs—1MP, 1MM and 3MM Main Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . . Main Service Modules . . . . . . . . . . . . . . . . . . . . . Surge Metering . . . . . . . . . . . . . . . . . . . . . . . . . . . Residential Meter Stacks. . . . . . . . . . . . . . . . . . . . 1MP, 1MM and 3MM Main Tenant Circuit Breakers. . . . . . . . . . . . . . . . . . . . . . . . . . Phase Balanced Stack . . . . . . . . . . . . . . . . . . . . . . Commercial Meter Stack Modules . . . . . . . . . . . . 35MM, 37MM, 35SS and 37SS Main Tenant Circuit Breakers . . . . . . . . . . . . . . . V1-T5-88 V1-T5-90 V1-T5-96 V1-T5-98 V1-T5-101 V1-T5-115 V1-T5-116 Features Eaton offers Type CCV (10 and 22 kAIC) and Type CV (42, 65 and 100 kAIC) family of circuit breakers as the primary tenant main breakers used in most group metering applications. ● ● Product Description Eaton’s residential products Type CCV circuit breaker is available in two-pole configurations from 100A to 225A in 10 and 22 kAIC ratings. ● 5 5 5 5 5 5 V1-T5-134 5 5 5 Standards and Certifications Ratings—120/240 Vac, two-pole, through 225 continuous amperes, calibrated at 40°C Tripping characteristics— thermal-magnetic trip, calibrated and sealed after assembly. Indirectly heated thermal tripping bimetal elements Interrupting capacity at 120/240 Vac. Type CCV— 10 kAIC rms symmetrical. Type CCVH—25 kAIC rms symmetrical 5 V1-T5-125 V1-T5-126 V1-T5-127 Type CCV 120/240V Tenant Main Circuit Breaker Product Overview 5 ● ● ● Handles—trip-free with ON-TRIPPED-OFF positions. Reset past OFF is required to latch breaker contacts after tripping Terminals—standard lugs (wire connectors) suitable for copper or aluminum wire Backward compatibility— Type CCV and CCVH retains same profile and footprint as the CC and CCH breaker, allowing use in the same applications ● Complies with UL Standard 489. Breakers are listed under UL File #E7819 5 5 5 5 5 5 5 5 5 Product Selection 5 Type CCV 120/240V Tenant Main Circuit Breaker 5 Two-Pole Breaker Ampere Rating Wire Size Range, Al/Cu 10 kAIC 25 kAIC 100 #2–300 kcmil CCV2100X CCVH2100X 125 CCV2125X CCVH2125X 150 CCV2150X CCVH2150X 175 CCV2175X CCVH2175X 200 CCV2200X CCVH2200X 225 CCV2225X CCVH2225X 5 5 5 5 5 Modification Codes ● X—load side terminals only 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-95 5.10 5 Metering Products Group Metering Contents Type CV Tenant Main Circuit Breaker Description 5 Systems for Residential and Commercial Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type CCV 120/240V Tenant Main Circuit Breaker . Type CV 120/240V Tenant Main Circuit Breaker . . Meter Packs—1MP, 1MM and 3MM Main Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . Main Service Modules . . . . . . . . . . . . . . . . . . . . . Surge Metering. . . . . . . . . . . . . . . . . . . . . . . . . . . Residential Meter Stacks . . . . . . . . . . . . . . . . . . . 1MP, 1MM and 3MM Main Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . Phase Balanced Stack. . . . . . . . . . . . . . . . . . . . . . Commercial Meter Stack Modules . . . . . . . . . . . . 35MM, 37MM, 35SS and 37SS Main Tenant Circuit Breakers . . . . . . . . . . . . . . . 5 5 5 5 5 5 5 5 5 Type CV 120/240V Tenant Main Circuit Breaker 5 Product Overview Features Eaton offers Type CCV (10 and 22 kAIC) and Type CV (42, 65 and 100 kAIC) family of circuit breakers as the primary tenant main breakers used in most group metering applications. ● 5 5 5 5 5 5 5 ● Product Description Eaton’s residential products Type CV molded-case circuit breaker is available in twoand three-pole configurations from 60A to 225A in 42, 65 and 100 kAIC ratings. ● 5 5 5 ● 5 5 ● 5 5 Ratings—120/240 Vac, two- and three-pole, through 225 continuous amperes, calibrated at 40°C Tripping characteristics— thermal-magnetic trip, calibrated and sealed after assembly. Indirectly heated thermal tripping bimetal elements; includes pushto-test button for routine preventive maintenance Interrupting capacity at 120/240 Vac ● Type CVS—42,000A rms symmetrical ● Type CV—65,000A rms symmetrical ● Type CVH—100,000A rms symmetrical Handles—trip-free with ON-TRIPPED-OFF positions. Reset past OFF is required to latch breaker contacts after tripping Terminals—standard lugs (wire connectors) suitable for copper or aluminum wire Standards and Certifications ● Complies with UL Standard 489. Breakers are listed under UL File #E7819 5 5 5 5 V1-T5-96 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Page V1-T5-88 V1-T5-90 V1-T5-95 V1-T5-96 V1-T5-98 V1-T5-101 V1-T5-115 V1-T5-116 V1-T5-125 V1-T5-126 V1-T5-127 V1-T5-134 5.10 Metering Products Group Metering Product Selection Type CV Two-Pole Tenant Main Circuit Breakers Main Tenant Number Circuit Breaker of Poles Ampere Rating Wire Size 42 kAIC Range, Catalog Al/Cu Number 2 #6–4/0 60 5 Type CV Three-Pole Tenant Main Circuit Breakers 65 kAIC 100 kAIC Catalog Number Catalog Number CVS2060XMM CV2060XMM CVH2060XMM 5 Main Tenant Number Circuit Breaker of Poles Ampere Rating Wire Size 42 kAIC Range, Catalog Al/Cu Number 65 kAIC 100 kAIC Catalog Number Catalog Number 5 3 #6–4/0 CVS3060X CV3060X CVH3060X 5 60 70 CVS2070XMM CV2070XMM CVH2070XMM 70 CVS3070X CV3070X CVH3070X 80 CVS2080XMM CV2080XMM CVH2080XMM 80 CVS3080X CV3080X CVH3080X 90 CVS2090XMM CV2090XMM CVH2090XMM 90 CVS3090X CV3090X CVH3090X 100 CVS2100XMM CV2100XMM CVH2100XMM 100 CVS3100X CV3100X CVH3100X 125 CVS2125XMM CV2125XMM CVH2125XMM 125 CVS3125X CV3125X CVH3125X 150 CVS2150XMM CV2150XMM CVH2150XMM 150 CVS3150X CV3150X CVH3150X 175 CVS2175XMM CV2175XMM CVH2175XMM 175 CVS3175X CV3175X CVH3175X 200 CVS2200XMM CV2200XMM CVH2200XMM 200 CVS3200X CV3200X CVH3200X 225 CVS2225XMM CV2225XMM CVH2225XMM 225 CVS3225X CV3225X CVH3225X 5 5 5 5 5 Accessories 5 Field Installable Description Catalog Number Two-pole 300 kcmil with terminal shield 2TA225CVK Three-pole 300 kcmil with terminal shield 3TA225CVK Replacement mounting hardware kit for 200A 1MP, 1MM and 3MM units 1MMCBK 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-97 5.10 5 Metering Products Group Metering Contents Main Tenant Circuit Breakers Description 5 5 5 5 5 5 5 5 5 5 Meter Packs—1MP, 1MM and 3MM Main Tenant Circuit Breakers 5 Product Description 5 5 5 Page Systems for Residential and Commercial Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type CCV 120/240V Tenant Main Circuit Breaker . Type CV 120/240V Tenant Main Circuit Breaker . . Meter Packs—1MP, 1MM and 3MM Main Tenant Circuit Breakers Main Service Modules . . . . . . . . . . . . . . . . . . . . . Surge Metering. . . . . . . . . . . . . . . . . . . . . . . . . . . Residential Meter Stacks . . . . . . . . . . . . . . . . . . . 1MP, 1MM and 3MM Main Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . Phase Balanced Stack. . . . . . . . . . . . . . . . . . . . . . Commercial Meter Stack Modules . . . . . . . . . . . . 35MM, 37MM, 35SS and 37SS Main Tenant Circuit Breakers . . . . . . . . . . . . . . . V1-T5-88 V1-T5-90 V1-T5-95 V1-T5-96 V1-T5-101 V1-T5-115 V1-T5-116 V1-T5-125 V1-T5-126 V1-T5-127 V1-T5-134 Specific main tenant circuit breakers that are to be used in meter packs (1MP), residential meter stacks (1MM) and three-phase in single-phase out meter stacks (3MM). 5 5 Product Selection 5 Main Tenant Circuit Breaker Ampere Rating 10 kAIC 22 kAIC 25 kAIC 65 kAIC 100 kAIC Number of Poles Catalog Number 1 Catalog Number Catalog Catalog Number 1234 Number 234 Catalog Number 234 Catalog Number 234 2 60 BR260 BRH260 — BRHH260 — — 2 70 BR270 BRH270 — BRHH270 — — 2 80 BR280 BRH280 — BRHH280 — — 2 90 BR290 BRH290 — BRHH290 — — 2 100 BR2100 BRH2100 — BRHH2100 — — 2 110 BR2110 BRH2110 — BRHH2110 — — 2 125 BR2125 BRH2125 — BRHH2125 — — 2 60 — — CVS2060XMM CVS2060XMM CV2060XMM CVH2060XMM 2 70 — — CVS2070XMM CVS2070XMM CV2070XMM CVH2070XMM 2 80 — — CVS2080XMM CVS2080XMM CV2080XMM CVH2080XMM 2 90 — — CVS2090XMM CVS2090XMM CV2090XMM CVH2090XMM 5 2 100 CCV2100X — CCVH2100X CVS2100XMM CV2100XMM CVH2100XMM 2 125 CCV2125X — CCVH2125X CVS2125XMM CV2125XMM CVH2125XMM 5 2 150 CCV2150X — CCVH2150X CVS2150XMM CV2150XMM CVH2150XMM 2 175 CCV2175X — CCVH2175X CVS2175XMM CV2175XMM CVH2175XMM 5 2 200 CCV2200X — CCVH2200X CVS2200XMM CV2200XMM CVH2200XMM 5 5 5 Description Plug-On Type Plug-on type circuit breakers used with 1MP, 1MM, and 3MM 125A modular metering stacks 5 5 5 5 5 5 42 kAIC Bolt-On Type Bolt-on type circuit breakers used with 1MP, 1MM, and 3MM 200A modular metering stacks Notes 1 #2–300 kcmil wire size range for CCV and CCVH tenant main circuit breakers. 2 “MM” suffix indicates mounting hardware kit is included as standard with tenant main breaker. 3 1MMCBK replacement mounting hardware kit. One kit is needed per breaker. Mounting hardware kit ships standard with breaker “MM” suffix offering. 4 #6–4/0 kcmil wire size range for CVS, CV and CVH tenant main circuit breakers. If #2–300 kcmil is needed, order 2TA225CVK. One kit needed per breaker. V1-T5-98 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Group Metering 5.10 Dimensions and Knockouts 5 Approximate Dimensions in Inches (mm) 5 1MP, 125 Ampere Meter Packs—Aluminum and Copper Bus 24.260 5 .450 5.610 "W" "X" "Y" "Z" .450 5.610 5.125 11.880 9.380 5.000 2.560 5 5 5 3.000 3.000 36.130 3.00 (76.2) "Z" = C L of 1/2" Ring "Y" = C L of 1-1/2" Ring "X" = C L of 1-1/2" Ring "W" = C L of 4" Ring 5 8.000 5.125 24.08 (611.6) 4.565 4.690 7.015 "W" 5 27.000 3.615 4.690 7.005 "X" "Y" 5 5, 6 Meter Device .695 4.555 5 Concentric Knockouts 1/2" Knockout Concentric Knockouts 1", 1-1/4", 1-1/2", Knockout Concentric Knockouts 2-1/2", 3", 3-1/2", 4 " Knockout Concentric Knockouts 1/2" Knockout 41.600 9.000 (1) Knockout for 1-1/2, 2, 2-1/2 Conduit 3, 4 Meter Device Concentric Knockouts 1", 1-1/4", 1-1/2", Knockout Concentric Knockouts 2-1/2", 3", 3-1/2", 4 " Knockout 14.460 5 3.625 (3) Knockout for 1, 1-1/4, 1-1/2 Conduit 6.560 7.015 5 12.550 9.000 48.290 12.552 9.000 9.000 9.000 34.250 To CL of Wall Mtg. Screw 21.699 CL Meter ToCL Rail Mtg. Screw 2.025 3.140 "Z" 5 36.280 Mtn. for 2, 2-1/2, 3" C-H Conduit Hubs 5 6.380 5.900 .060 2.250 5 1", 1-1/4", 1-1/2" Knockouts (6 Required) 1/2" Knockout 2.625 2.313 5 23.750 1-1/2", 2", 2-1/2", 3" Knockouts 34.180 5 .875 5 57 Mtg Holes 4 Places 1, 1-1/4, 1-1/2" KO 6 Places 1.500 1.438 4.375 4.389 2.313 5 2.750 1.880 1.806 5 1.440 1.063 .438 5 2.750 2.880 4.000 3.063 Dia. Hub Opening 5 2.277 5 3.688 3.250 5 2.563 6.500 Bottom Endwall Knockouts for Units with "T" Suffix 3, 4 Meter Device 3.063 5 Top View 5 5 3.250 2.563 6.500 5 Bottom Endwall Knockouts for Units with "T" Suffix 5, 6 Meter Device 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-99 5.10 Approximate Dimensions in Inches (mm) 1MP, 200 Ampere Meter Packs—Aluminum and Copper Bus 25.480 25.480 5 2.015 5 5 5 2 Meter Device 5 5 3.125 7.015 5 12.125 52.415 12.125 5 Typ. 3.000 5.125 24.080 "Z" = C L of 1/2" Ring "Y" = C L of 1-1/2" Ring C "X" = L of 1-1/2" Ring "W" = C L of 4" Ring 5, 6 Meter Device Concentric Knockouts 2-1/2", 3", 3-1/2", 4 " Knockout Concentric Knockouts 1", 1-1/4", 1-1/2", 2" Knockout Concentric Knockouts 1/2" Knockout 4.565 27.000 .695 3.625 "W" "X" "Y" "Z" .450 5.610 3.000 8.000 3.000 7.015 4.690 6.555 5 5 5.610 18.425 5 5 .450 2, 3 & 4 Meter Endwall 5 5 "W" "X" "Y" "Z" 3.250 2.563 6.500 38.635 Bottom Endwall Knockouts for Units with "T" Suffix 2, 3, 4 Meter Device 5 5 5 3.250 5 2.563 6.500 Bottom Endwall Knockouts for Units with "T" Suffix 5, 6 Meter Device 5 5 V1-T5-100 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 7.005 5 3.615 4.690 5 3, 4 Meter Device Concentric Knockouts 1/2" Knockout Concentric Knockouts 1", 1-1/4", 1-1/2", 2" Knockout Concentric Knockouts 4.555 15.000 2-1/2", 3", 3-1/2", 4 " Knockout 2.015 5 5 (4) Knock Out For 1", 1-1/4", 1-1/2", 2" Conduit 38.755 5 64.535 12.125 12.125 18.400 5 18.425 5 15.826 CL Meter To CL Rail Mtg. Screw 12.155 5 12.125 2.015 34.250 To CL of Wall Mtg. Screw 5 Group Metering 42.685 5 Metering Products Metering Products Group Metering 5.10 Contents Description Page Systems for Residential and Commercial Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type CCV 120/240V Tenant Main Circuit Breaker . Type CV 120/240V Tenant Main Circuit Breaker . . Meter Packs—1MP, 1MM and 3MM Main Tenant Circuit Breakers. . . . . . . . . . . . . . . . . . . . Main Service Modules Surge Metering . . . . . . . . . . . . . . . . . . . . . . . . . . . Residential Meter Stacks . . . . . . . . . . . . . . . . . . . 1MP, 1MM and 3MM Main Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . Phase Balanced Stack . . . . . . . . . . . . . . . . . . . . . . Commercial Meter Stack Modules . . . . . . . . . . . . 35MM, 37MM, 35SS and 37SS Main Tenant Circuit Breakers . . . . . . . . . . . . . . . V1-T5-88 V1-T5-90 V1-T5-95 V1-T5-96 V1-T5-98 V1-T5-115 V1-T5-116 ● ● ● ● ● ● Main terminal box Main circuit breaker Main bolted pressure switch Main fusible switch Main fusible switch with pull box Underground pull box Application Description Main Circuit Breakers with Busway Connections The Service Entrance Product Team announces the availability of both main fusible switch and main circuit breaker group metering mains with busway connections. This offering provides us with the ability to offer multiple tenant metering in high rise apartment buildings where riser busway is used. 5 5 5 5 5 5 V1-T5-125 V1-T5-126 V1-T5-127 5 V1-T5-134 5 5 5 Main Service Modules Product Description 5 5 Features, Benefits and Functions Eaton’s Main Service Module ● Offering: main terminal/lug compartment, main circuit breaker, main fusible switch, main bolted pressure switch, main fusible switch with pull box (meets EUSERC electrical requirements), underground pull box termination compartment without cross bus (meets EUSERC electrical requirements) ● Mechanically and electrically built for use with 1MM, 3MM, 35MM, 37MM, 35SS and 37SS modular metering stacks ● For integrated system short-circuit ratings with main devices, see series ratings on Page V1-T5-142 ● All main service modules include both left and right horizontal bus closure plates ● Two-pole devices are applied to single-phase, three-wire, 120/240V or 208Y/120V systems, threepole devices to 208Y/240V or 120/240V delta systems ● ● ● ● Single-phase mains couple to any modular metering stack (1MM, 3MM, 35MM, 37MM, 35SS and 37SS) Three-phase mains require three-phase bussed stacks. These modular metering stacks are 3MM, 35MM, 37MM, 35SS and 37SS If the ampere rating of the main service module is greater than the horizontal bus rating of the meter stack (residential or commercial), the main service module must be center fed. Examples: 1200A Main Circuit Breaker (1MCB1200R) with an 800A residential stack (1MM512R). 1600A Main Terminal Box (3MTB1600R) with a 1200A residential stack (3MM212R12) Most main service modules are available with aluminum or copper bus Main Circuit Breakers with Busway Connections ● Three-phase, 400–200A main circuit breakers ● Three-phase, 400–800A main fusible switches ● Simple bridge joint connection ● Variety of options: ● Right or left mounting ● Internal ground or housing ground ● The MFS/MCB and busway connector are supplied completely assembled 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-101 5.10 5 Metering Products Group Metering Catalog Number Selection 5 3 MTB 400 R 5 Phase 1 = Single-phase 3 = Three-phase 5 5 5 5 5 Accessories and Additional Options BLK= Box lug kit (accessory) CLK= Compression lug (accessory) B = Bottom feed T = Top feed UG= Pull box Blank= No options Enclosure R = NEMA 3R Ampere Rating 400A 600A 800A 1000A 1200A 1400A 1600A 2000A 5 5 5 Bus Material C = Copper bus Blank= Aluminum bus Type of Metering BTB = Main terminal box MCB = Main circuit breaker BPS = Bolted pressure switch MFS = Main fusible switch UGPB = Underground pull box MTBE = Main terminal box with utility pull box MCBE = Main circuit breaker with utility pull box 5 5 C When Ordering: 1. Determine catalog number of Main Service Module. 5 2. Determine catalog number of Meter Stack (Residential or Commercial). 5 3. Find quantity and catalog numbers for tenant circuit breakers (found on Page V1-T5-125 or V1-T5-135). Order one breaker per socket. 5 4. If any accessories are needed, order from Pages V1-T5-136 and V1-T5-137. 5 5 5 5 5 5 5 5 5 5 5 5 5 5 V1-T5-102 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Group Metering 5.10 Product Selection 5 Main Terminal Box ● Phase and neutral lugs are included ● Top or bottom feed: ● For top feed, use Myer type hub Main Terminal Box ● ● 5 Indoor or outdoor Terminal box UL listed short-circuit rating is the least AIC rating of any installed main tenant breaker—to a maximum of 100,000 rms symmetrical amperes 5 5 5 5 Main Terminal Box System Voltage Ampere Rating Line Side Lug and Wire Sizes—Included 120/208 Vac Three-Phase, Four-Wire Catalog Number Catalog Number 5 Use three-phase 3MTB400R 5 Aluminum Bus (Standard Offering) (1) #6–600 or (2) 1/0–250 kcmil 2 400 3 600 (2) 250–500 kcmil 800 (4) 250–500 kcmil 45 1200 1 (4) 250–500 kcmil 56 5 120/240 Vac Single-Phase, Three-Wire Use three-phase 3MTB600R 1MTB800R 3MTB800R 1MTB1200R 3MTB1200R 5 5 5 Aluminum Bus (EUSERC) 400 Crimp lug landing pads (no lugs included) 1MTBE400R 7 3MTBE400R 7 800 Crimp lug landing pads (no lugs included) 1MTBE800R 7 3MTBE800R 7 5 5 Copper Bus (Premium Offering) kcmil 2 400 (1) #6–600 or (2) 1/0–250 Use three-phase 3MTB400RC 600 (2) 250–500 kcmil 3 Use three-phase 3MTB600RC (4) 250–500 kcmil 45 1MTB800RC 3MTB800RC (4) 250–500 kcmil 56 1MTB1200RC 3MTB1200RC (6) 500 kcmil 8 1MTB1600RC 3MTB1600RC 800 1200 1 1600 1 Main Terminal Box Riser Panel Eaton’s Main Terminal Box Riser Panel is a main terminal box with offset lugs on each phase to allow riser cables to pass through the main service module. 5 5 5 5 These panels are used in the construction of assisted living homes, dormitories, public housing complexes and apartments. 5 5 5 Main Terminal Box Riser Panel System Voltage Ampere Rating Line and Load Side Lug and Wire Sizes Included 120/240 Vac Single-Phase, Three-Wire Catalog Number 120/208 Vac Three-Phase, Four-Wire Catalog Number 1200 #2 AWG–750 kcmil 19 Use three-phase 3MTB1200RCRIS 1600 #2 AWG–750 kcmil 19 Use three-phase 3MTB1600RCRIS Copper Bus (Standard Offering) 5 5 5 Notes 1 1200A main devices must be center fed when installing 800A residential meter stacks. 1600A main devices must be center fed when installing 800–1200A residential and commercial meter stacks. 2 For 400A units, to obtain (4) 750 kcmil cables per phase—order quantity 4 1MPLK2. Kit contains one lug. 3 For compression lug landing kits for 600A units, order 3MTB600CLK. Kit includes lug landings for three phases and neutral. 4 For 800A units, to obtain (4) 1/0–300 kcmil or (2) 1/0–750 kcmil cables per phase—order catalog number 3MTB800BLK, one lug kit per main terminal box ordered (neutral and ground included in kit). 5 For 800A and 1200A units, for compression lug landing kits, order 3MTB1200CLK. Kit includes lug landings for three-phase and neutral. 6 For 1200A units, to obtain (6) 1/0–300 kcmil or (3) 750 kcmil cables per phase—order catalog number 3MTB1200BLK, one lug kit per main terminal box ordered (neutral and ground included in kit). 7 Meets EUSERC electrical requirements and eliminates the need to add additional pull box section. 8 For 1600A units, to obtain (4) 750 kcmil cables per phase—order catalog number 3MTB1600BLK, one lug kit per main terminal box ordered. For a 1600A compression lug landing kit, order catalog number 3MTB1600CLK. 9 Quantity (10) lugs per phase—quantity (5) lugs incoming and quantity (5) lugs outgoing per phase. Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 5 5 5 5 5 5 V1-T5-103 5.10 5 5 5 5 5 Metering Products Group Metering Main Circuit Breaker ● Phase and neutral lugs included. If additional neutral lugs are needed, order 1MCB1200NLK for (3) 1/0–750 or (6) 1/0–300 kcmil ● For shunt trip mains, order the field-installable shunt trip kit in this volume, Tab 1, section 1.1 ● ● For overhead feed, use Myer type hub. Verify local utility approval For compression lugs on 400, 600, 800, 1000 and 1200A units, add CL to the end of the part number (includes copper lug pads for lines and neutral) ● ● 1200A or greater main devices must be center fed when installing 800A residential meter stacks 1400, 1600 and 2000A main devices must be center fed when installing 800 and 1200A residential and commercial meter stacks 5 5 Main Circuit Breaker 5 Main Circuit Breaker Main Ampere Rating 5 Main Circuit Breaker Type System Voltage Feed kAIC Line Side Lug and Wire Sizes (Lugs Included with Main Breaker) 1 120/240 Vac 120/208 Vac Single-Phase, Three-Wire Three-Phase, Four-Wire Catalog Number Catalog Number Aluminum Bus (Standard Offering) 5 250 KD Bottom/top 65 (2) 3/0–250 kcmil or (1) 2/0–500 kcmil 1MCB250R 3MCB250R 250 HKD Bottom/top 100 (2) 3/0–250 kcmil or (1) 2/0–500 kcmil 1MHCB250R 3MHCB250R 5 300 KD Bottom/top 65 (2) 3/0–250 kcmil or (1) 2/0–500 kcmil 1MCB300R 3MCB300R 300 HKD Bottom/top 100 (2) 3/0–250 kcmil or (1) 2/0–500 kcmil 1MHCB300R 3MHCB300R 5 350 KD Bottom/top 65 (2) 3/0–250 kcmil or (1) 2/0–500 kcmil 1MCB350R 3MCB350R 350 HKD Bottom/top 100 (2) 3/0–250 kcmil or (1) 2/0–500 kcmil 1MHCB350R 3MHCB350R 5 400 KD Bottom/top 65 (2) 3/0–250 kcmil or (1) 2/0–500 kcmil 1MCB400R 2 400 HKD Bottom/top 100 (2) 3/0–250 kcmil or (1) 2/0–500 kcmil 1MHCB400R 5 500 LD Bottom/top 65 (2) 400–500 kcmil 1MCB500R 3MCB500R 5 500 HLD Bottom/top 100 (2) 400–500 kcmil 1MHCB500R 3MHCB500R 600 LD Bottom/top 65 (2) 400–500 kcmil 1MCB600R 2 3MCB600R 2 600 HLD Bottom/top 100 (2) 400–500 kcmil 1MHCB600R 2 3MHCB600R 2 700 HMDL Bottom/top 100 (3) 3/0–400 kcmil 1MHCB700R 3MHCB700R 700 MDL Bottom/top 65 (3) 3/0–400 kcmil 1MCB700R 3MCB700R 3MCB800R 2 5 5 2 3MCB400R 2 3MHCB400R 2 800 MDL Bottom/top 65 (3) 3/0–400 kcmil 1MCB800R 2 5 800 MDL Bottom/top 65 (2) 500–750 kcmil 1MCB800R750 3MCB800R750 800 HMDL Bottom/top 100 (3) 3/0–400 kcmil 1MHCB800R 2 3MHCB800R 2 5 900 NGS Bottom/top 65 (4) 4/0–500 kcmil 3 1MCB900R 4 3MCB900R 4 900 NGH Bottom/top 100 (4) 4/0–500 kcmil 3 kcmil 3 1MHCB900R 4 3MHCB900R 4 1MCB1000R 24 3MCB1000R 24 5 1000 NGS Bottom/top 65 (4) 4/0–500 1000 NGS Bottom/top 65 (2) 500–750 kcmil 1MCB1000R750 3MCB1000R750 5 1000 NGH Bottom/top 100 (4) 4/0–500 kcmil 3 1MHCB1000R 24 3MHCB1000R 24 1200 NGS Bottom 65 (4) 4/0–500 kcmil 3 1MCB1200R 24 3MCB1200R 24 5 1200 NGH Bottom 100 (4) 4/0–500 kcmil 3 1MHCB1200R 24 3MHCB1200R 24 1200 NGS Bottom 65 (2) 500–750 kcmil Use three-phase 3MCB1200R750 5 Notes 1 If additional neutral lugs are needed, order 1MCB1200NLK [(3) 1/0–750 kcmil or (6) 1/0–300 kcmil]. 2 Add CL to end of catalog number for compression lug pads (includes lug pads for lines and neutral). 3 If (3) 500–750 kcmil are needed, order TA1201NB1. Order one kit per pole. 4 Main devices with a rating greater than 800A can be used with 800A residential modular stacks, but only as a center fed main. 5 5 5 5 5 5 5 V1-T5-104 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 5.10 Metering Products Group Metering Main Circuit Breaker Main Circuit Breaker 5 5 Main Circuit Breaker, continued Main Ampere Rating System Voltage Main Circuit Breaker Type Feed kAIC Line Side Lug and Wire Sizes (Lugs Included with Main Breaker) 1 120/240 Vac 120/208 Vac Single-Phase, Three-Wire Three-Phase, Four-Wire Catalog Number Catalog Number Aluminum Bus (EUSERC) 300 KD Bottom/top 65 Crimp lug landing pads (no lugs included) 1MCBE300R 3MCBE300R 350 KD Bottom/top 65 Crimp lug landing pads (no lugs included) 1MCBE350R 3MCBE350R 400 KD Bottom/top 65 Crimp lug landing pads (no lugs included) 1MCBE400R 3MCBE400R 400 HKD Bottom/top 100 Crimp lug landing pads (no lugs included) 1MHCBE400R 3MHCBE400R 500 LD Bottom/top 65 Crimp lug landing pads (no lugs included) 1MCBE500R 3MCBE500R 600 LD Bottom/top 65 Crimp lug landing pads (no lugs included) 1MCBE600R 3MCBE600R 600 HLD Bottom/top 100 Crimp lug landing pads (no lugs included) 1MHCBE600R 3MHCBE600R 800 MDL Bottom/top 65 Crimp lug landing pads (no lugs included) 1MCBE800R 3MCBE800R 5 5 5 5 5 5 5 5 800 HMDL Bottom/top 100 Crimp lug landing pads (no lugs included) 1MHCBE800R 3MHCBE800R 1000 NGS Bottom/top 65 Crimp lug landing pads (no lugs included) 1MCBE1000R 3MCBE1000R 1200 NGS Bottom 65 Crimp lug landing pads (no lugs included) 1MCBE1200R 3MCBE1200R 1200 NGH Bottom 100 Crimp lug landing pads (no lugs included) 1MHCBE1200R 3MHCBE1200R 5 5 5 Copper Bus (Premium Offering) 400 KD Bottom/top 65 (2) 3/0–250 kcmil or (1) 2/0-500 kcmil 1MCB400RC 2 3MCB400RC 2 400 HKD Bottom/top 100 2/0–500 kcmil 1MHCB400RC 2 3MHCB400RC 2 600 LD Bottom/top 65 (2) 300–500 kcmil 1MCB600RC 2 3MCB600RC 2 2 600 HLD Bottom/top 100 (2) 300–500 kcmil 1MHCB600RC 800 MDL Bottom/top 65 (3) 3/0–400 kcmil 1MCB800RC 2 5 3MHCB600RC 2 5 3MCB800RC 2 2 3MHCB800RC 2 800 HMDL Bottom/top 100 (3) 3/0–400 kcmil 1MHCB800RC 900 NGS Bottom/top 65 (4) 4/0–500 kcmil 3 1MCB900RC 4 3MCB900RC 4 900 NGH Bottom/top 100 (4) 4/0–500 kcmil 3 1MHCB900RC 4 3MHCB900RC 4 1000 NGS Bottom/top 65 (2) 500–750 kcmil 1MCB1000R750C 3MCB1000R750C 1000 NGS Bottom/top 65 (4) 4/0–500 kcmil 3 1MCB1000RC 24 3MCB1000RC 24 1000 NGH Bottom/top 100 (4) 4/0–500 kcmil 3 1MHCB1000RC 24 3MHCB1000RC 24 1200 NGS Bottom 65 (2) 500–750 kcmil Use three-phase 3MCB1200R750C kcmil 3 1200 NGS Bottom 65 (4) 4/0–500 1200 NGH Bottom 100 (4) 4/0–500 kcmil 3 1MCB1200RC 24 3MCB1200RC 5 5 24 1MHCB1200RC 24 3MHCB1200RC 24 46 46 kcmil 5 1MCB1400RBC 1400 RGH Bottom 100 (4) 500–1000 1400 RGH Top 100 (4) 500–1000 kcmil 5 1MCB1400RT 7 3MCB1400RBC 3MCB1400RT 7 1600 RGH Bottom 100 (4) 500–1000 kcmil 5 1MCB1600RBC 67 3MCB1600RBC 67 1600 RGH Top 100 (4) 500–1000 kcmil 5 1MCB1600RT 7 3MCB1600RT 7 2000 RGH Bottom 100 (6) #2–600 kcmil 1MCB2000RBC 68 3MCB2000RBC 68 2000 RGH Top 100 (6) #2–600 kcmil 1MCB2000RT 8 3MCB2000RT 8 Bottom 100 Crimp lug landing pads (no lugs included) 1MCBE1000RC 3MCBE1000RC NGH 1200 NGS Bottom 65 Crimp lug landing pads (no lugs included) 1MCBE1200RC 3MCBE1200RC 1200 NGH Bottom 100 Crimp lug landing pads (no lugs included) 1MHCBE1200RC 3MHCBE1200RC 5 5 5 5 5 5 Notes 1 If additional neutral lugs are needed, order 1MCB1200NLK [(3) 1/0–750 kcmil or (6) 1/0–300 kcmil]. 2 Add CL to end of catalog number for compression lug pads (includes lug pads for lines and neutral). 3 If (3) 500–750 kcmil are needed, order TA1201NB1. Order one kit per pole. 4 Main devices with a rating greater than 800A can be used with 800A residential modular stacks but only as a center fed main. 5 If (6) #2–600 kcmil lugs are needed, order TA2000RD. Catalog number includes terminals and hardware for three poles. If neutral is needed, order TA2000N. 6 Copper bus. 7 Main devices with a rating greater than 1200A can be used with residential and commercial modular metering stacks but only as a center fed main. 8 Only to be used in center feed applications with 1200A meter stacks. Not to be used with 800A stacks. Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 5 5 Copper Bus (EUSERC) 1000 5 5 5 5 5 V1-T5-105 5.10 Metering Products Group Metering 5 Main Fusible Switches ● Fuses not included ● Main lugs and neutral included with device ● 100 kAIC rating on switches with Class T fuses installed. If converting to Class H, the kAIC rating is 10 and if converted to Class R, the kAIC rating is 200 5 Note: This is the fuse rating, switch still rated at 100 kAIC. 5 5 5 5 ● ● 800A top and bottom fed units are supplied with Class T fuse clips as standard. The Class T fuse clips are field convertible to Class L by repositioning. No kit is needed Barrier kits available for 400A–800A fusible switches: Bottom feed—3MFSBBK, Top feed—3MFSTBK 5 5 Main Fusible Switches Main Fusible Switches System Voltage 5 Class Fuse Clips (Fuses Not Included) 5 Ampere Rating 5 Aluminum Bus (Standard Offering) 400 5 Feed Bottom Line Side Box Lugs and Wire Sizes (Included with Switch) 120/240 Vac Single-Phase, Three-Wire 120/208 Vac Three-Phase, Four-Wire Catalog Number Catalog Number T1 (2) 1/0–300 kcmil or (1) 750 kcmil 45 1MFS400RB 3MFS400RB 1 (2) 1/0–300 kcmil or (1) 750 kcmil 56 1MFS400RT 3MFS400RT 400 Top T 600 Bottom T2 (2) #2–600 kcmil 45 1MFS600RB 3MFS600RB 5 600 Top T2 (2) #2–600 kcmil 56 1MFS600RT 3MFS600RT 5 800 Bottom T, L 3 (4) 3/0–750 kcmil 4 1MFS800RB 3MFS800RB 800 Top T, L 3 (4) 3/0–750 kcmil 6 1MFS800RT 3MFS800RT 1MFS1200RB 3MFS1200RB 3MFS400RBC 5 1200 5 400 Bottom T, L 3 (4) #2–600 kcmil 7 Copper Bus (Premium Offering) Bottom T1 (2) 1/0–300 kcmil or (1) 750 kcmil 45 1MFS400RBC 1 (2) 1/0–300 kcmil or (1) 750 kcmil 56 1MFS400RTC 3MFS400RTC 3MFS600RBC 400 Top T 600 Bottom T2 (2) #2–600 kcmil 45 1MFS600RBC 5 600 Top T2 (2) #2–600 kcmil 56 1MFS600RTC 3MFS600RTC 800 Bottom T, L 3 (4) 3/0–750 kcmil 4 1MFS800RBC 3MFS800RBC 5 800 Top T, L 3 (4) 3/0–750 kcmil 6 1MFS800RTC 3MFS800RTC 1MFS1200RBC 3MFS1200RBC 5 1200 5 Bottom T, L 3 (4) #2–600 kcmil 7 Notes 1 If Class H fuse clips are needed, use catalog number WCG3HK400 (order (1) per phase). If Class R fuse clips are needed, order catalog number DS56FK in addition to WCG3HK400. In order to go from T to R, the device must first be converted to H. All kits are field installable and each DS56FK kit will convert three poles. 2 If Class H fuse clips are needed, use catalog number WCG3HK600 (order (1) per phase). If Class R fuse clips are needed, order catalog number DS66FK in addition to WCG3HK600. In order to go from T to R, the device must first be converted to H. All kits are field installable and each DS66FK kit will convert three poles. 3 Class T fuse clips provided are field convertible to Class L by repositioning. No kit is needed. 4 If compression lugs are being used, order 3MFS800CLK. This compression lug kit includes four pads (three poles and neutral). 5 1MFS600BLK (4) 3/0–750 kcmil/phase (one kit/phase and one kit/neutral). 6 If compression lugs are being used, order 3MFS800CLKT. This compression lug kit includes four pads (three poles and neutral). 7 IMFS1200LK (3) 750 kcmil/phase (one kit/phase). IMFS1200LKN (3) 750 kcmil (neutral). 5 5 5 5 5 5 5 5 5 5 V1-T5-106 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 5.10 Metering Products Group Metering Main Fusible Switch with Utility Pull Box ● Fuses not included ● Includes lug landing pads on line side and neutral ● Spacer kit 3MMBSK required when stacks are mounted on right-hand side in EUSERC areas ● 100 kAIC rating on switches with Class T fuse clips installed Main Fusible Switch with Utility Pull Box 5 5 5 5 5 5 5 Main Fusible Switch with Utility Pull Box System Voltage Ampere Rating Feed Class Fuse Clips (Fuses Not Included) Line Side Box Lugs and Wire Sizes (Included with Switch) 120/240 Vac Single-Phase, Three-Wire 120/208 Vac Three-Phase, Four-Wire Catalog Number Catalog Number 5 5 5 Aluminum Bus (Standard Offering) 400 Bottom T 1 1MFS400RUG 3MFS400RUG 600 Bottom T 1 1MFS600RUG 3MFS600RUG 800 Bottom T, L 1 1MFS800RUG 3MFS800RUG 1200 Bottom T 1 1MFS1200RUG 3MFS1200RUG 5 5 5 Copper Bus (Premium Offering) 400 Bottom T 1 1MFS400RUGC 3MFS400RUGC 600 Bottom T 1 1MFS600RUGC 3MFS600RUGC 1MFS800RUGC 3MFS800RUGC 1MFS1200RUGC 3MFS1200RUGC 800 Bottom T, L 1 1200 Bottom T 1 5 5 5 Utility Pull Box ● Includes lug landing pads on line side and neutral ● Requires cable connection in field to main device; does not include horizontal cross bus 5 5 5 5 5 Pull Box System Voltage Ampere Rating Feed Line Side Lug Information 120/240 Vac Single-Phase, Three-Wire 120/208 Vac Three-Phase, Four-Wire Catalog Number Catalog Number 5 5 Aluminum Bus (Standard Offering) Bottom 1 1/0–750 kcmil or (2) 1/0–300 kcmil 1UGPB400R 3UGPB400R 800 Bottom 1 (2) 1/0–750 kcmil or (4) 1/0–300 kcmil 1UGPB800R 3UGPB800R 1200 Bottom 1 (4) #2–600 kcmil 1UGPB1200R 3UGPB1200R 3UGPB400RC 400 5 5 Copper Bus (Premium Offering) Bottom 1 1/0–750 kcmil or (2) 1/0–300 kcmil 1UGPB400RC 800 Bottom 1 (2) 1/0–750 kcmil or (4) 1/0–300 kcmil 1UGPB800RC 3UGPB800RC 1200 Bottom 1 (4) #2–600 kcmil 1UGPB1200RC 3UGPB1200RC 400 5 Load Side Lug Information for Cable Connection to Main Disconnect 5 5 Note 1 Pull box section includes landing studs for line side compression lugs. Wire sizes refer to load side connection. 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-107 5.10 5 5 5 5 5 5 5 5 Metering Products Group Metering Main Bolted Pressure Contact Switches ● Add suffix ST to catalog number for shunt trip ● Fuses not included ● 100 kAIC rating on switches with Class L fuses installed Main Bolted Pressure Contact Switches System Voltage Ampere Rating Feed 120/240 Vac Single-Phase, Three-Wire Class Fuse Clips (Fuses Not Included) Catalog Number 120/208 Vac Three-Phase, Four-Wire Catalog Number Line Side Box Lugs and Wire Sizes (Included) Copper Bus 5 1200 Bottom L 1BPS1200RB 3BPS1200RB (4) #4–600 kcmil 1200 Top L 1BPS1200RT 3BPS1200RT (4) #4–600 kcmil 5 1600 Bottom L Use three-phase 3BPS1600RB (6) #4–600 kcmil 1600 Top L Use three-phase 3BPS1600RT (6) #4–600 kcmil 2000 Bottom L Use three-phase 3BPS2000RB (8) #4–600 kcmil 2000 Top L Use three-phase 3BPS2000RT (8) #4–600 kcmil 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 V1-T5-108 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Group Metering Main Circuit Breaker with Busway Connection Verify proper left/right–bus/main phasing. Note: “Right” means that the bus duct is to the right of the main and “left” means that the bus duct is to the left of the main. (See Dimension/ Layout section for clarification.) Feed 400 Bottom 600 Bottom 800 Bottom 400 Bottom 600 Bottom 800 Bottom 400 Bottom 600 Bottom 800 Bottom 400 Bottom 600 Bottom 800 Bottom 400 Bottom 600 Bottom 800 Bottom 400 Bottom 600 Bottom 800 Bottom 400 Bottom 600 Bottom 800 Bottom 400 Bottom 600 Bottom 800 Bottom 400 Bottom 400 Bottom 600 Bottom 600 Bottom 800 Bottom 800 Bottom 1000 Bottom 1000 Bottom 1200 Bottom 1200 Bottom 400 Bottom 400 Bottom 600 Bottom 600 Bottom 800 Bottom 800 Bottom 1000 Bottom 1000 Bottom 1200 Bottom 1200 Bottom 400 Bottom 400 Bottom System Voltage 120/208 Vac Three-Phase, Four-Wire Catalog Number Internal Ground or Housing Ground Standard T or TO Right Opposite or Left Phasing Side Ampere Rating Feed 3MFS400BCRGTO 3MFS600BCRGTO 3MFS800BCRGTO 3MFS400BCLGTO 3MFS600BCLGTO 3MFS800BCLGTO 3MFS400BCRGT 3MFS600BCRGT 3MFS800BCRGT 3MFS400BCLGT Internal TO Right 1200 Bottom Internal TO Right 1200 Bottom Internal TO Right 400 Bottom Internal TO Left 400 Bottom Internal TO Left 600 Bottom Internal TO Left 600 Bottom Internal T Right 800 Bottom Internal T Right 800 Bottom Internal T Right 1000 Bottom Internal T Left 1000 Bottom 3MFS600BCLGT 3MFS800BCLGT 3MFS400BCRNTO Internal T Left 1200 Bottom Internal T Left 1200 Bottom Housing TO Right 400 Bottom 3MFS600BCRNTO 3MFS800BCRNTO 3MFS400BCLNTO 3MFS600BCLNTO 3MFS800BCLNTO 3MFS400BCRNT 3MFS600BCRNT 3MFS800BCRNT 3MFS400BCLNT 3MFS600BCLNT 3MFS800BCLNT 3MCB400BCRGT Housing TO Right 400 Bottom Housing TO Right 600 Bottom Housing TO Left 600 Bottom Housing TO Left 800 Bottom Left 800 Bottom T Right 1000 Bottom Housing T Right 1000 Bottom Housing T Right 1200 Bottom Bottom Housing T Left 1200 Housing T Left 400 Bottom Bottom T Left Internal T Right 600 Bottom 3HMCB400BCRGT 3MCB600BCRGT 3HMCB600BCRGT Internal T Right 600 Bottom Internal T Right 800 Bottom Internal T Right 800 Bottom Internal T Right 1000 Bottom Internal T Right 1000 Bottom Internal T Right 1200 Bottom Internal T Right 1200 Bottom Internal T Right 400 Bottom Internal T Right 400 Bottom Internal T Left 600 Bottom Internal T Left 600 Bottom Internal T Left 800 Bottom Internal T Left 800 Bottom Internal T Left 1000 Bottom Internal T Left 1000 Bottom Internal T Left 1200 Bottom Internal T Left 1200 Bottom Internal T Left 400 Bottom Internal T Left 400 Bottom Housing T Right 600 Bottom Housing T Right 600 Bottom Bottom Bottom 800 Bottom 1000 Bottom 1000 Bottom 3HMBC1000BCRNT Bottom TO Housing Housing 800 Bottom 600 Housing 400 3MCB800BCRGT 3HMCB800BCRGT 3MCB1000BCRGT 3HMCB1000BCRGT 3MCB1200BCRGT 3HMCB1200BCRGT 3MCB400BCLGT 3HMCB400BCLGT 3MCB600BCLGT 3HMCB600BCLGT 3MCB800BCLGT 3HMCB800BCLGT 3MCB1000BCLGT 3HMCB1000BCLGT 3MCB1200BCLGT 3HMCB1200BCLGT 3MCB400BCRNT 3HMCB400BCRNT 3MCB600BCRNT 3HMCB600BCRNT 3MCB800BCRNT 3HMCB800BCRNT 3MBC1000BCRNT 600 Using this information, select the correct main device catalog number per the selection chart. Main Circuit Breaker with Busway Connection, continued Main Circuit Breaker with Busway Connection Ampere Rating 5.10 Housing T Right 800 Housing T Right 800 Bottom Bottom Housing T Right 1000 Housing T Right 1000 Bottom Housing T Right 1200 Bottom Housing T Right 1200 Bottom System Voltage 120/208 Vac Three-Phase, Four-Wire Catalog Number Internal Ground or Housing Ground Standard T or TO Right Opposite or Left Phasing Side 3MCB1200BCRNT 3HMCB1200BCRNT 3MCB400BCLNT 3HMCB400BCLNT 3MCB600BCLNT 3HMCB600BCLNT 3MCB800BCLNT Housing T Right Housing T Right Housing T Left Housing T Left Housing T Left Housing T Left Housing T Left 3HMCB800BCLNT 3MCB1000BCLNT 3HMCB1000BCLNT 3MCB1200BCLNT 3HMCB1200BCLNT 3MCB400BCRGTO Housing T Left Housing T Left Housing T Left Housing T Left Housing T Left Internal TO Right 3HMCB400BCRGTO 3MCB600BCRGTO 3HMCB600BCRGTO Internal TO Right Internal TO Right Internal TO Right 3MCB800BCRGTO 3HMCB800BCRGTO 3MCB1000BCRGTO 3HMCB1000BCRGTO 3MCB1200BCRGTO 3HMCB1200BCRGTO 3MCB400BCLGTO 3HMCB400BCLGTO 3MCB600BCLGTO 3HMCB600BCLGTO 3MCB800BCLGTO 3HMCB800BCLGTO Internal TO Right Internal TO Right Internal TO Right Internal TO Right Internal TO Right Internal TO Right Internal TO Left Internal TO Left Internal TO Left Internal TO Left Internal TO Left Internal TO Left 3MCB1000BCLGTO 3HMCB1000BCLGTO 3MCB1200BCLGTO 3HMCB1200BCLGTO 3MCB400BCRNTO 3HMCB400BCRNTO 3MCB600BCRNTO 3HMCB600BCRNTO 3MCB800BCRNTO 3HMCB800BCRNTO 3MCB1000BCRNTO 3HMCB1000BCRNTO 3MCB1200BCRNTO 3HMCB1200BCRNTO 3MCB400BCLNTO 3HMCB400BCLNTO 3MCB600BCLNTO 3HMCB600BCLNTO 3HMCB800BCLNTO 3HMCB800BCLNTO 3MCB1000BCLNTO 3HMCB1000BCLNTO 3MCB1200BCLNTO 3HMCB1200BCLNTO Internal TO Left Internal TO Left Internal TO Left Internal TO Left Housing TO Right Housing TO Right Housing TO Right Housing TO Right Housing TO Right Housing TO Right Housing TO Right Housing TO Right Housing TO Right Housing TO Right Housing TO Left Housing TO Left Housing TO Left Housing TO Left Housing TO Left Housing TO Left Housing TO Left Housing TO Left Housing TO Left Housing TO Left Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-109 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5.10 5 5 Metering Products Group Metering Dimensions Approximate Dimensions in Inches (mm) Dimensions (Not to be Used for Construction Purposes) 5 Center Line of Wall Mounting Bracket Knockouts in Bottom Endwalls Except No KOs for Top Feed Switch or Bolted Pressure Switch Conduit Diameter Width Height Depth Mounting A B C D E F Inches mm 400 and 600A 13.50 (342.9) 48.75 (1238.3) 7.00 (177.8) — 54.00 (1371.6) 30.63 (777.9) (1) 2.50, 3.00, 3.50, 4.00 (1) 0.50 (1) 63.5, 76.2, 88.9, 101.6 (1) 12.7 1 800 and 1200A 20.00 (508.0) 47.63 (1209.8) 11.75 (298.5) 12.00 (304.8) 51.50 (1308.1) 30.63 (777.9) (2) 12.1, 19.1, 25.4 (4) 50.8, 63.5, 76.2, 88.9, 101.6 2 5 (2) 0.50, 0.75, 1.00 (4) 2.00, 2.50, 3.00, 3.50, 4.00 1600A 32.88 (835.2) 60.13 (1527.3) 11.44 (290.6) 16.00 (406.4) 64.13 (1628.9) 38.59 (980.2) (1) 19.1, 25.4, 31.8, 38.1 (5) 76.2, 88.9, 101.6, 127.0 3 5 (1) 0.75, 1.00, 1.25, 1.50 (5) 3.00, 3.50, 4.00, 5.00 Main Circuit Breaker with Box Lugs 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Main Device KO Dwg. Terminal Box 400–1200A 20.00 (508.0) 47.63 (1209.8) 11.75 (298.5) 12.00 (304.8) 51.50 (1308.1) 30.63 (777.9) (2) 0.50, 0.75, 1.00 (4) 2.00, 2.50, 3.00,3.50, 4.00 (2) 12.7, 19.1, 25.4 (4) 50.8, 63.5, 76.2, 88.9, 101.6 2 1400–2000A 24.88 (632.0) 57.13 (1451.0) 14.88 (378.0) 16.00 (406.4) 57.13 (1451.0) 44.00 (1117.6) — — — Main Circuit Breaker with Compression Lugs 400–1200A 20.00 (508.0) 61.00 (1549.4) 11.75 (298.5) 12.00 (304.8) 65.00 (1651.0) 44.00 (1117.6) (2) 0.50, 0.75, 1.00 (4) 2.00, 2.50, 3.00, 3.50, 4.00 (2) 12.7, 19.1, 25.4 (4) 50.8, 63.5, 76.2, 88.9, 101.60 2 Main Fusible Switch Bottom feed 400–800A 20.00 (508.0) 47.63 (1209.8) 11.75 (298.5) 12.00 (304.8) 51.50 (1308.1) 30.63 (777.9) (2) 0.50, 0.75, 1.00 (4) 2.00, 2.50, 3.00, 3.50, 4.00 (2) 12.7, 19.1, 25.4 (4) 50.8, 63.5, 76.2, 88.9, 101.6 2 Top feed 400–800A 20.00 (508.0) 47.63 (1209.8) 11.75 (298.5) 12.00 (304.8) 51.50 (1308.1) 18.13 (460.4) (2) 0.50, 0.75, 1.00 (4) 2.00, 2.50, 3.00, 3.50, 4.00 (2) 12.7, 19.1, 25.4 (4) 50.8, 63.5, 76.2, 88.9, 101.6 2 1200A 33.50 (850.9) 52.75 (1339.9) 11.88 (301.8) 16.00 (406.4) 56.25 (1428.8) 30.75 (781.1) (5) 3.50, 4.00, 5.00 (1) 0.75, 1.00, 1.25, 1.50 (5) 88.9, 101.6, 127.0 (1) 19.1, 25.4, 31.8, 38.1 4 66.50 (1689.1) 19.50 (495.3) 28.00 (711.2) 60.00 (1524.0) 30.63 (777.9) — — — Bolted Pressure Switch 36.50 (927.1) Main Fusible Switch with Pull Box 400A 20.00 (508.0) 61.00 (1549.4) 11.75 (298.5) 12.00 (304.8) 65.00 (1651.0) 44.00 (1117.6) (2) 0.50, 0.75, 1.00 (4) 2.00, 2.50, 3.00, 3.50, 4.00 (2) 12.7, 19.1, 25.4 (4) 50.8, 63.5, 76.2, 88.9, 101.6 2 600 and 800A (single-phase) 20.00 (508.0) 61.00 (1549.4) 11.75 (298.5) 12.00 (304.8) 65.00 (1651.0) 44.00 (1117.6) (2) 0.50, 0.75, 1.00 (4) 2.00, 2.50, 3.00, 3.50, 4.00 (2) 12.7, 19.1, 25.4 (4) 50.8, 63.5, 76.2, 88.9, 101.6 2 600 and 800A (three-phase) 25.06 (636.5) 61.00 (1549.4) 11.75 (298.5) 17.00 (431.8) 65.00 (1651.0) 44.00 (1117.6) (2) 0.50, 0.75, 1.00 (4) 2.00, 2.50, 3.00, 3.50, 4.00 (2) 12.7, 19.1, 25.4 (4) 50.8, 63.5, 76.2, 88.9, 101.6 4 1200A 33.50 (850.9) 61.50 (1562.1) 11.88 (301.8) 16.00 (406.4) 65.25 (1657.4) 48.00 (1219.2) (5) 3.50, 4.00, 5.00 (1) 0.75, 1.00, 1.25, 1.50 (5) 88.9, 101.6, 127.0 (1) 19.1, 25.4, 31.8, 38.1 4 5 Main Circuit Breaker with Pull Box (EUSERC) 5 400A 20.01 (508.2) 60.44 (1535.2) 11.14 (283.0) 12.00 (304.8) 65.11 (1653.8) 39.75 (1009.6) (4) 2.50, 3.00, 3.50, 4.00 (4) 63.5, 76.2, 88.9, 101.6 2 800A 24.88 (632.0) 60.94 (1547.9) 11.14 (283.0) 17.00 (431.8) 64.88 (1648.0) 39.81 (1011.2) (4) 2.50, 3.00, 3.50, 4.00 (4) 63.5, 76.2, 88.9, 101.6 2 1200A 33.00 (838.2) 61.14 (1553.0) 11.32 (287.5) 16.00 (406.4) 65.25 (1657.4) 43.56 (1106.4) (4) 2.50, 3.00, 3.50, 4.00 (4) 63.5, 76.2, 88.9, 101.6 4 5 5 5 5 5 5 5 5 5 Pull Box 400A 16.38 (416.1) 44.88 (1140.0) 7.88 (200.2) 8.00 (203.2) 45.75 (1162.1) 28.63 (727.2) (2) 4.00 101.6 5 800A 24.38 (619.3) 46.88 (1190.8) 11.88 (301.8) 12.00 (304.8) 47.75 (1212.9) 32.25 (819.2) (3) 4.00 101.6 6 1200A 32.50 (825.5) 56.88 (1444.8) 12.00 (304.8) 17.75 (450.9) 57.75 (1466.9) 42.25 (1073.2) (4) 5.00 127.0 7 EUSERC Bussed Pull Section Single-phase 400 and 800A 20.13 (511.3) 61.00 (1549.4) 11.25 (285.8) 12.00 (304.8) 64.88 (1648.0) 44.00 (1117.6) (4) 2.50, 3.00, 3.50, 4.00 (4) 63.5, 76.2, 88.9, 101.6 5 Three-phase 400 and 800A 25.13 (638.3) 61.00 (1549.4) 11.88 (301.8) 17.00 (431.8) 64.88 (1648.0) 44.00 (1117.6) (4) 2.50, 3.00, 3.50, 4.00 (4) 63.5, 76.2, 88.9, 101.6 6 EUSERC Main Terminal Box Single-phase 400 and 800A 20.13 (511.3) 61.00 (1549.4) 11.88 (301.8) 12.00 (304.8) 64.88 (1648.0) 44.00 (1117.6) (2) 0.50, 0.75, 1.00 (2) 12.7, 19.1, 25.4 2 Three-phase 400A 20.13 (511.3) 61.00 (1549.4) 11.88 (301.8) 12.00 (304.8) 64.88 (1648.0) 44.00 (1117.6) (4) 2.00, 2.50, 3.00, 3.50, 4.00 (4) 50.8, 63.5, 76.2, 88.9, 101.6 2 Three-phase 800A 25.13 (638.3) 61.00 (1549.4) 11.88 (301.8) 17.00 (431.8) 64.88 (1648.0) 44.00 (1117.6) (4) 2.00, 2.50, 3.00, 3.50, 4.00 (4) 50.8, 63.5, 76.2, 88.9, 101.6 2 V1-T5-110 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 5.10 Metering Products Group Metering Approximate Dimensions in Inches (mm) Main Circuit Breakers, Terminal Boxes and Pull Boxes 5 Bolted Pressure Switch A A 5 C 5 5 E 5 B E 5 B F F 5 5 C D Top Feed Fusible Switch 5 EUSERC Main Terminal Box C A 5 25.00 (635.0) D Main CB, Non-Euserc Terminal Box and Pullboxes A 5 C 5 5 E 5 B B 5 5 F 5 5 17.00 (431.8) Top Feed Switch (No Knockouts) D 5 Bottom Feed Fusible Switch and Combination Fusible Switch with Pull Box 5 5 C A 5 5 E 5 B 5 F 5 5 17.00 (431.8) Bottom Feed Switch and Combination Switch/Pullbox D 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-111 5.10 5 5 5 5 5 Group Metering Approximate Dimensions in Inches (mm) Knockout 5 Knockout 1 .625 .010 .080 .020 5.375 .010 3.500 .010 6.850 .020 KO (10) KO (10) 7.000 +.000 –.030 3.000 .020 Stamped ID Mark .200 .020 Typ. .780 .020 Typ. 12.375 .010 .175 .010 +.003 .169 –.000 Diameter 5 Hole Knockout 6 Knockout 2 .45 22.54 11.62 .61 .250 Ref. 3.75 10.38 2.50 5 5 6.120 .020 CL .438 .010 5 5 2.880 .030 3.010 .010 .150 .020 Typ. .875 .020 5 5 3.250 .020 KO (44) 5 5 .150 .020 Typ. .080 .020 2.880 .010 .800 .030 6.000 .020 5.000 .020 2-1/2”, 3”, 3-1/2”, 4” KO 1 Knockout Required .310 .030 Diameter 2.500 Paint Hole .020 1/2”Knockout 1 Required Per 50-1827-1 KO (1) 6.500 Outside .010 5 Metering Products .150 .020 Typ. 1.93 4.250 .150 .020 .020 Typ. 3.25 2.50 1.75 4.25 .220 Dia. .250 Paint Ref. Hole 11.19 2 Knockouts for 1/2”, 3/4” or 1” Conduit .281 Diameter Knockout 1 Required 6.000 .020 6.000 .020 6.000 .020 10.120 .020 KO (10) KO (10) 11.000 +.000 -.030 10.850 .020 KO (10) 4.000 .020 .16 4 Knockouts for 2-1/2”, 3”, 3-1/2” or 4” Conduit .200 .020 Typ. 8.00 8.00 .780 .020 Typ. 4.00 A 19.40 5 5 5 5 1.500 .020 2.125 .020 4.250 .020 5.125 .020 7.250 .020 .220 Dia. Paint Hole 7.250 .020 7.250 .020 .150 .020 Typ. .350 Ref. KO (11) 10.140 .020 KO (11) 10.850 .020 .130 .030 6.000 .010 6.000 .010 3”, 3-1/2”, 4”, 5” Knockout Per A50-26327 5 Knockouts Required 6.000 .010 6.000 .010 .169 .002 Diameter 5 Holes Required at ”X” KO (11) 11.000 +.000 –.030 4.000 .020 .685 .020 Typ. .125 .030 .120 .020 Typ. 4.440 .020 Knockout 8 22.54 11.62 .61 .281 Dia. Knockout 1 Required 3.75 10.38 2.50 2 Knockouts for 1/2", 3/4", or 1" Conduit 1.93 3.25 2.50 1.75 5 .150 .020 Typ. .350 Ref. KO (11) .45 5 5 6.000 .010 1.440 .020 Knockout 4 5 5 6.000 .010 2.750 .010 5 5 6.000 .010 6.000 .010 32.120 .020 6.000 .010 2.750 7.500 .010 .020 2.750 .010 5 5 2.125 .020 3/4”, 1”, 1-1/4”, 1-1/2” Knockout Per A50-26319 1 Knockout Required 4.000 .020 .380 .020 5 5 Knockout 7 Knockout 3 4 Knockouts for 2-1/2", 3", 3-1/2" or 4" Conduit 24.38 2 Knockouts for 1/2", 3/4", or 1" Conduit 8.00 4.00 8.00 4.25 11.19 2 Knockouts for 1/2”, 3/4” or 1” Conduit .281 Diameter Knockout 1 Required 4 Knockouts for 2-1/2”, 3”, 3-1/2” or 4” Conduit B 4.25 .16 4.75 3.13 1.75 1.75 2.50 8.00 8.00 4.00 1.50 0.50 19.40 15.38 16.63 2.50 3.63 27.13 5 V1-T5-112 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 3.75 2.13 11.25 Metering Products Group Metering 5.10 Approximate Dimensions in Inches (mm) 5 Layout—Main Fusible Switch 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-113 5.10 5 5 5 Metering Products Group Metering Approximate Dimensions in Inches (mm) Main Circuit Breaker—“T-Opposite” Phasing Right 8.48 (215.4) CLVertical Wall 5 Main Circuit Breaker—“Standard T” Phasing Right 8.48 (215.4) CLVertical Wall 5 5 Meter Center Front 5 T-Opposite 38.76 (984.5) 5 T-Opposite 5 Meter Center Front 38.76 (984.5) CL Horizontal 18.17 (461.5) 18.17 (461.5) 5 T-Opposite 20.00 (508.0) 6.00 (152.4) 5 T-Opposite 5 CL Horizontal 20.00 (508.0) 30.08 (764.0) 6.00 (152.4) 30.08 (764.0) Floor 5 Floor 5 5 5 Main Circuit Breaker—“T-Opposite” Phasing Left Main Circuit Breaker—“Standard T” Phasing Left 5 5 8.48 Wall (215.4) CLVertical 8.48 Wall (215.4) CLVertical 5 5 Meter Center Front T-Opposite 5 5 T-Opposite 5 38.76 (984.5) 38.76 (984.5) CL Horizontal 18.17 (461.5) 5 5 T-Opposite 30.08 (764.0) T-Opposite 5 5 Meter Center Front 18.17 (461.5) 20.00 (508.0) 6.00 (152.4) 20.00 (508.0) 30.08 (764.0) 6.00 (152.4) Floor Floor 5 5 5 V1-T5-114 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com CL Horizontal Metering Products Group Metering 5.10 Contents Surge Metering Description Surge suppression devices shown are factory mounted in Group Metering Enclosure. Page Systems for Residential and Commercial Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type CCV 120/240V Tenant Main Circuit Breaker . Type CV 120/240V Tenant Main Circuit Breaker . . Meter Packs—1MP, 1MM and 3MM Main Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . . Main Service Modules . . . . . . . . . . . . . . . . . . . . . Surge Metering Residential Meter Stacks. . . . . . . . . . . . . . . . . . . . 1MP, 1MM and 3MM Main Tenant Circuit Breakers. . . . . . . . . . . . . . . . . . . . . . . . . . Phase Balanced Stack . . . . . . . . . . . . . . . . . . . . . . Commercial Meter Stack Modules . . . . . . . . . . . . 35MM, 37MM, 35SS and 37SS Main Tenant Circuit Breakers . . . . . . . . . . . . . . . V1-T5-88 V1-T5-90 V1-T5-95 V1-T5-96 V1-T5-98 V1-T5-101 5 5 5 5 5 5 V1-T5-116 5 V1-T5-125 V1-T5-126 V1-T5-127 5 V1-T5-134 5 5 5 Surge Metering Product Description Eaton’s multiple metering product family is proud to announce the availability of main surge devices. The new main surge is mounted between the main service module and the meter stacks and serves the purpose of providing surge protection for downstream multiple metering products. The main surge is compatible with all meter stacks currently manufactured (1MM, 3MM, 35MM and 37MM). Features, Benefits and Functions ● ● ● ● Uses thermally protected metal oxide varistor (MOV) technology Compatible with 37MM enclosure accessories Protection status indicator lights EMI/RFI filtering and audible alarms Offers surge protection for all units fed from a main service module Standards and Certifications ● ● ● Benefit for building/complex owners who want to offer surge protection to their tenants. Owner can market their apartment complex as being surge friendly to appliances and electronics Attain local utility company approval. Not for use in EUSERC area UL 1449 3rd Edition recognized component 5 5 5 5 5 5 5 5 Product Selection 5 Surge Metering 5 Voltage Surge Current per Phase (kA) Diagnostics Catalog Number 5 120/240V single-phase 100 Standard 1MMSURGE 208Y/120V three-phase 100 Standard 3MMSURGE 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-115 5.10 5 Metering Products Group Metering Contents 1MM and 3MM Metering Stack Modules Description 5 5 5 5 5 5 5 5 5 5 Residential Meter Stacks 5 Features, Benefits and Functions 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Page Systems for Residential and Commercial Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type CCV 120/240V Tenant Main Circuit Breaker . Type CV 120/240V Tenant Main Circuit Breaker . . Meter Packs—1MP, 1MM and 3MM Main Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . Main Service Modules . . . . . . . . . . . . . . . . . . . . . Surge Metering. . . . . . . . . . . . . . . . . . . . . . . . . . . Residential Meter Stacks 1MP, 1MM and 3MM Main Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . Phase Balanced Stack. . . . . . . . . . . . . . . . . . . . . . Commercial Meter Stack Modules . . . . . . . . . . . . 35MM, 37MM, 35SS and 37SS Main Tenant Circuit Breakers . . . . . . . . . . . . . . . A. Barrier Meter socket and tenant main breaker/wireway sections are separated by a solid metal barrier to guard unmetered bus against power theft. B. Tenant Breaker Reliable busbar–to–busbar connection. 200A modules accept bolt-on breakers 60– 200A. 125A modules accept 15–125A plug-on breakers. C. Moveable Phase Connector Four-wire horizontal bus lets you use any 3MM module for single- or three-phase incoming service. Shipped with A and B phase connection, phase balancing is easily accomplished in the field by moving one, frontaccessible phase connector post per module. D. Neutral Assembly A convenient termination for neutral conductors is in the wireway of each module. 5 5 5 E. Enclosed Horizontal Bus Added security because a non-removable barrier encloses the 800 or 1200A horizontal bus passing through tenant breaker section. F. Equipment Ground Bar Factory installed in side gutter, a standard feature that’s moveable to the top or bottom gutter. G. Raintight Cap Shipped on each outdoor meter module and main device. H. Knockouts Tangential in bottom endwall. I. Superior Finish Rust inhibiting phosphate primer and gray baked enamel is standard. All outdoor enclosures are of galvanized steel construction. K. Bus Connection Mains and modules slip together quickly and smoothly with frontaccessible captive bolts securing the juncture without removing socket interiors or bus access plate. Main bus joint bolts torque to 25 foot pounds. L. Separate Wireway Cover Separate covers allow easy access to tenant breaker and wireway section, permit work on breakers or in wireway without disturbing meters or meter covers. (Not shown.) 5 V1-T5-116 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-98 V1-T5-101 V1-T5-115 V1-T5-125 V1-T5-126 V1-T5-127 V1-T5-134 1MM Meter Stack Module G A M B J I C D E M. Vertical Busbar One-piece vertical busbar from phase balancing joints to meter socket eliminating any chance for hot spots. J. Meter Socket Our unique meter socket base is installed without any fasteners—reducing chances for hot spots, easily replaceable, and improves connection to vertical bus. V1-T5-88 V1-T5-90 V1-T5-95 V1-T5-96 K F H Metering Products Group Metering ● ● ● Eaton’s 1MM stacks are single-phase in, singlephase out design Eaton’s 3MM stacks are three-phase in, singlephase out design Stacks with single-phase horizontal bus are rated 240/120V, single-phase, three-wire. Stacks with three-phase horizontal bus are rated 208Y/120V, threephase, four-wire, but can be used on 240/120V, three-phase, four-wire delta systems ● All three-phase horizontal bus modules have fourwire cross bus, connected A-B phase to vertical bus, readily reconnectable for phase balance on installation Note: Individual sockets cannot be phase balanced, only each stack. ● Short-circuit ratings up to 100,000A rms symmetrical depending upon AIC rating of installed main tenant circuit breakers and main device ● ● ● ● Main tenant feeders can exit bottom or back. Knockouts are available at all exit locations If being used in outdoor application and exiting the top, mount Myer type hubs on rainproof cap Provision for two-pole breaker (plug-on type for 125A sockets and bolt-on type for 200A sockets)— circuit breakers not included Mechanically and electrically built to bolt-up with main service modules and commercial modular metering stacks ● ● ● ● 5.10 Aluminum or copper bus 800 or 1200A horizontal bus All 3MM stacks include fifth jaw at 9 o’clock position All 1MM stacks do not include fifth jaw. Order 1MM5JK if needed 5 5 5 5 5 5 5 5 5 Catalog Number Selection 5 1 MM 4 12 R 5 12 C 5 Phases 1 = Single-phase 3 = Three-phase Type of Metering MM = Multiple metering Number of Meters 2, 3, 4, 5 or 6 Blank = Accessory Ampere Rating 12 = 125A 20 = 200A Blank = Accessory Enclosure R = Outdoor Blank = Indoor Options Blank = Ring RL = Ringless RLB = Ringless with horn bypass WB = Wall bracket (accessory) BSK = Bussed spacer (accessory) EB12 = 12-inch (304.8 mm) elbow (accessory) EB16 = 16-inch (406.4 mm) elbow (accessory) Bus Type Blank = Aluminum C = Copper 5 5 5 5 Bus Amperes 12 = 200A horizontal bus (3MM units only) Blank = Standard 800A bus 5 5 When Ordering: 1. Determine catalog number of Main Service Module. 5 2. Determine catalog number of Meter Stack (Residential or Commercial). 5 3. Find quantity and catalog numbers for tenant circuit breakers (found on Page V1-T5-125 or V1-T5-135). Order one breaker per socket. 5 4. If any accessories are needed, order from Pages V1-T5-136 and V1-T5-137. 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-117 5.10 5 5 5 Metering Products Group Metering Product Selection 1MM and 3MM Metering Stack Modules 800A Horizontal Aluminum Bus—Standard Offering Amperes Per Meter Socket 5 5 Number of Meter Sockets Bus Ampacity Enclosure Type 1 Main Tenant Breaker Type (For Specific Catalog Numbers, Refer to Page V1-T5-125) Single-Phase In, Single-Phase Out Three-Phase In, Single-Phase Out Single-Phase Horizontal Bus (Three Horizontal Busbars— A, B and Neutral) 2 Three-Phase Horizontal Bus (Four Horizontal Busbars— A, B, C and Neutral) Catalog Number Catalog Number Use three-phase 3MM212R Ring Style Meter Socket Covers 125 3 5 5 5 200 5 5 5 5 24 800 Indoor/outdoor 34 800 Indoor/outdoor 4 800 Indoor/outdoor Plug-on type BR2_ BRH2_ BRHH2_ 1MM312R 3MM312R 1MM412R 3MM412R 5 800 Indoor/outdoor 1MM512R 3MM512R 6 800 Indoor/outdoor 1MM612R 3MM612R 2 800 Outdoor Use three-phase 3MM220R 3 800 Outdoor 1MM320R 3MM320R 4 800 Outdoor 5 800 Outdoor Bolt-on type CCV2_X CCVH2_X CVS2_XMM CV2_XMM CVH2_XMM 1MM420R 3MM420R 1MM520R 6 3MM520R 5 Ringless Style Meter Socket Covers 125 2 800 Outdoor 3 800 Outdoor 5 4 800 Outdoor 5 800 5 6 2 5 200 5 5 5 Use three-phase 3MM212RRL 1MM312RRL 3MM312RRL 1MM412RRL 3MM412RRL Outdoor 1MM512RRL 3MM512RRL 800 Outdoor 1MM612RRL 3MM612RRL 800 Outdoor Use three-phase 3MM220RRL 1MM320RRL 3MM320RRL 3 800 Outdoor 4 800 Outdoor 5 Plug-on type BR2_ BRH2_ BRHH2_ 800 Outdoor Bolt-on type CCV2_X CCVH2_X CVS2_XMM CV2_XMM CVH2_XMM 1MM420RRL 1MM520RRL 3MM420RRL 6 3MM520RRL 5 Ringless Style Covers with Horn Bypass 125 5 5 5 200 5 5 5 2 800 Outdoor 3 800 Outdoor 4 800 Outdoor Plug-on type BR2_ BRH2_ BRHH2_ Use three-phase 3MM212RRLB 1MM312RRLB 3MM312RRLB 1MM412RRLB 3MM412RRLB 5 800 Outdoor 1MM512RRLB 3MM512RRLB 6 800 Outdoor 1MM612RRLB 3MM612RRLB 2 800 Outdoor 3 800 Outdoor 4 800 Outdoor 5 800 Outdoor Bolt-on type CCV2_X CCVH2_X CVS2_XMM CV2_XMM CVH2_XMM Use three-phase 3MM220RRLB 1MM320RRLB 3MM320RRLB 1MM420RRLB 3MM420RRLB 1MM520RRLB 6 3MM520RRLB 5 Notes 1 For indoor applications where a top endwall with knockouts is needed, order one of part number MM12N1WLK for each 125A stack or MM20N1WLK for each 200A stack. 2 1MM units do not come with 5th jaw. 3 To change in field from ring to ringless—order 1MMRC125. 4 To change in field from ring to ringless, the top socket in 125A, two- and three-high stacks use 1MMRC125T. Top socket only—other sockets see 3. 5 To change in field from ring to ringless—order 1MMRC200. 6 Check with local utility for height requirements or restrictions. 5 5 5 5 5 5 5 V1-T5-118 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 5.10 Metering Products Group Metering 1MM and 3MM Metering Stack Modules 800A Horizontal Copper Bus—Premium Offering Amperes Per Meter Socket Number of Meter Sockets Bus Ampacity Enclosure Type 1 Main Tenant Breaker Type (For Specific Catalog Numbers, Refer to Page V1-T5-125) 5 Single-Phase In, Single-Phase Out Three-Phase In, Single-Phase Out Single-Phase Horizontal Bus (Three Horizontal Busbars— A, B, C and Neutral) 2 Three-Phase Horizontal Bus (Four Horizontal Busbars— A, B, C and Neutral) Catalog Number Catalog Number Use three-phase 3MM212RC 200 5 24 800 Outdoor 34 800 Outdoor 4 800 Outdoor 5 800 6 2 Plug-on type BR2_ BRH2_ BRHH2_ 1MM312RC 3MM312RC 1MM412RC 3MM412RC Outdoor 1MM512RC 3MM512RC 800 Outdoor 1MM612RC 3MM612RC 800 Outdoor Use three-phase 3MM220RC 3 800 Outdoor 4 800 Outdoor 5 800 Outdoor Bolt-on type CCV2_X CCVH2_X CVS2_XMM CV2_XMM CVH2_XMM 1MM320RC 3MM320RC 1MM420RC 3MM420RC 1MM520RC 6 3MM520RC 5 Use three-phase 3MM212RRLC 5 5 5 5 5 5 Ringless Style Meter Socket Covers 125 200 2 800 Outdoor 3 800 Outdoor 4 800 Outdoor Plug-on type BR2_ BRH2_ BRHH2_ 1MM312RRLC 3MM312RRLC 1MM412RRLC 3MM412RRLC 5 800 Outdoor 1MM512RRLC 3MM512RRLC 6 800 Outdoor 1MM612RRLC 3MM612RRLC 2 800 Outdoor Use three-phase 3MM220RRLC 3 800 Outdoor 4 800 Outdoor 5 800 Outdoor Bolt-on type CCV2_X CCVH2_X CVS2_XMM CV2_XMM CVH2_XMM 5 5 5 5 1MM320RRLC 3MM320RRLC 1MM420RRLC 3MM420RRLC 1MM520RRLC 6 3MM520RRLC 5 5 Use three-phase 3MM212RRLBC 5 Ringless Style Covers with Horn Bypass 125 200 2 800 5 5 Ring Style Meter Socket Covers 125 3 5 Outdoor 3 800 Outdoor 4 800 Outdoor Plug-on type BR2_ BRH2_ BRHH2_ 1MM312RRLBC 3MM312RRLBC 1MM412RRLBC 3MM412RRLBC 5 800 Outdoor 1MM512RRLBC 3MM512RRLBC 6 800 Outdoor 1MM612RRLBC 3MM612RRLBC 2 800 Outdoor Use three-phase 3MM220RRLBC 3 800 Outdoor 1MM320RRLBC 3MM320RRLBC 4 800 Outdoor 1MM420RRLBC 3MM420RRLBC 5 800 Outdoor 1MM520RRLBC 6 3MM520RRLBC 5 Bolt-on type CCV2_X CCVH2_X CVS2_XMM CV2_XMM CVH2_XMM 5 5 5 5 5 5 Notes 1 For indoor applications where a top endwall with knockouts is needed, order (1) of part number MM12N1WLK for each 125A stack or MM20N1WLK for each 200A stack. 2 1MM units do not come with 5th jaw. 3 To change in field from ring to ringless—order 1MMRC125. 4 To change in field from ring to ringless, the top socket in 125A, two- and three-high stacks use 1MMRC125T. Top socket only—other sockets see 3. 5 To change in field from ring to ringless—order 1MMRC200. 6 Check with local utility for height requirements or restrictions. 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-119 5.10 5 5 1MM and 3MM Metering Stack Modules Metering Products Group Metering 1200A Horizontal Aluminum Bus—Standard Offering Three-Phase In, Single-Phase Out Amperes Per Meter Socket 5 Number of Meter Sockets Bus Ampacity Enclosure Type 1 Main Tenant Breaker Type (For Specific Catalog Numbers, Refer to Page V1-T5-116) Three-Phase Horizontal Bus (Four Horizontal Busbars— A, B, C and Neutral) Catalog Number Ring Style Meter Socket Covers 5 125 2 5 5 23 1200 Indoor/outdoor 33 1200 Indoor/outdoor 4 1200 Indoor/outdoor 5 1200 Indoor/outdoor 6 1200 Indoor/outdoor 2 1200 Outdoor 5 3 1200 Outdoor 4 1200 Outdoor 5 5 1200 Indoor/outdoor 5 200 4 Plug-on type BR2_ BRH2_ BRHH2_ 3MM212R12 3MM312R12 3MM412R12 3MM512R12 3MM612R12 Bolt-on type CCV2_X CCVH2_X CVS2_XMM CV2_XMM CVH2_XMM 3MM220R12 3MM320R12 3MM420R12 3MM520R12 Ringless Style Meter Socket Covers (5th Jaw at 9 o’Clock Standard—Field Adjustable to 3 or 6 o’Clock) 5 125 2 1200 Outdoor 5 3 1200 Outdoor 4 1200 Outdoor 5 5 1200 Outdoor 3MM512R12RL 6 1200 Outdoor 3MM612R12RL 5 200 2 1200 Outdoor 5 3 1200 Outdoor 4 1200 Outdoor 5 5 1200 Outdoor Plug-on type BR2_ BRH2_ BRHH2_ Bolt-on type CCV2_X CCVH2_X CVS2_XMM CV2_XMM CVH2_XMM 3MM212R12RL 3MM312R12RL 3MM412R12RL 3MM220R12RL 3MM320R12RL 3MM420R12RL 3MM520R12RL Ringless Style Covers with Horn Bypass (5th Jaw at 9 o’Clock Standard—Field Adjustable to 3 or 6 o’Clock) 5 125 2 1200 Outdoor 5 3 1200 Outdoor 4 1200 Outdoor 5 5 1200 Outdoor 6 1200 Outdoor 2 1200 Outdoor 3 1200 Outdoor 4 1200 Outdoor 5 1200 Outdoor 5 200 5 5 Plug-on type BR2_ BRH2_ BRHH2_ 3MM212R12RLB 3MM312R12RLB 3MM412R12RLB 3MM512R12RLB 3MM612R12RLB Bolt-on type CCV2_X CCVH2_X CVS2_XMM CV2_XMM CVH2_XMM 3MM220R12RLB 3MM320R12RLB 3MM420R12RLB 3MM520R12RLB Notes 1 For indoor applications where a top endwall with knockouts is needed, order (one) of part number MM12N1WLK for each 125A stack or MM20N1WLK for each 200A stack. 2 To change in field from ring to ringless—order 1MMRC125. 3 To change in field from ring to ringless, the top socket in 125A, two- and three-high stacks use 1MMRC125T. Top socket only—other sockets see 2. 4 To change in field from ring to ringless—order 1MMRC200. 5 5 5 5 5 5 5 5 5 V1-T5-120 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Group Metering 1MM and 3MM Metering Stack Modules 5.10 1200A Horizontal Copper Bus—Premium Offering Three-Phase In, Single-Phase Out Amperes Per Meter Socket Number of Meter Sockets Bus Ampacity Enclosure Type 1 Main Tenant Breaker Type (For Specific Catalog Numbers, Refer to Page V1-T5-116) 5 Three-Phase Horizontal Bus (Four Horizontal Busbars— A, B, C and Neutral) 5 Catalog Number Ring Style Meter Socket Covers 125 2 200 4 23 1200 Indoor/outdoor 33 1200 Indoor/outdoor 4 1200 Indoor/outdoor 5 1200 Indoor/outdoor 6 1200 Indoor/outdoor 2 1200 Outdoor 3 1200 Outdoor 4 1200 Outdoor 5 1200 Outdoor Plug-on type BR2_ BRH2_ BRHH2_ 5 3MM212R12C 3MM312R12C 5 3MM412R12C 3MM512R12C 5 3MM612R12C Bolt-on type CCV2_X CCVH2_X CVS2_XMM CV2_XMM CVH2_XMM 3MM220R12C 5 3MM320R12C 3MM420R12C 5 3MM520R12C 5 Ringless Style Meter Socket Covers (5th Jaw at 9 o’Clock Standard—Field Adjustable to 3 or 6 o’Clock) 125 200 2 1200 Outdoor 3 1200 Outdoor 4 1200 Outdoor 5 1200 Outdoor 3MM512R12RLC 6 1200 Outdoor 3MM612R12RLC 2 1200 Outdoor 3 1200 Outdoor 4 1200 Outdoor 5 1200 Outdoor Plug-on type BR2_ BRH2_ BRHH2_ Bolt-on type CCV2_X CCVH2_X CVS2_XMM CV2_XMM CVH2_XMM 3MM212R12RLC 5 3MM312R12RLC 3MM412R12RLC 5 5 3MM220R12RLC 3MM320R12RLC 5 3MM420R12RLC 3MM520R12RLC 5 Ringless Style Covers with Horn Bypass (5th Jaw at 9 o’Clock Standard—Field Adjustable to 3 or 6 o’Clock) 125 200 2 1200 Outdoor 3 1200 Outdoor 4 1200 Outdoor 5 1200 Outdoor 6 1200 Outdoor 2 1200 Outdoor 3 1200 Outdoor 4 1200 Outdoor 5 1200 Outdoor Plug-on type BR2_ BRH2_ BRHH2_ 5 3MM212R12RLBC 3MM312R12RLBC 5 3MM412R12RLBC 3MM512R12RLBC 5 3MM612R12RLBC Bolt-on type CCV2_X CCVH2_X CVS2_XMM CV2_XMM CVH2_XMM 5 3MM220R12RLBC 5 3MM320R12RLBC 3MM420R12RLBC 5 3MM520R12RLBC 5 Technical Data and Specifications 5 Wire Sizes—Neutral and Ground Lugs ● Each stack includes a neutral and ground bar ● If an extra ground bar is needed, order 1MMGBK 5 5 Wire Sizes—Neutral and Ground Lugs Lugs in Meter Socket Modules Wire Size, Al/Cu 5 Branch neutral—125A socket module #6–2/0 kcmil Branch neutral—200A socket module #1/0–300 kcmil 5 Equipment ground bar—125A socket module #14–#2 kcmil Equipment ground bar—200A socket module #14–2/0 kcmil Optional ground bar (1MMGBK) #6–2/0 kcmil 5 5 Notes 1 For indoor applications where a top endwall with knockouts is needed, order (one) of part number MM12N1WLK for each 125A stack or MM20N1WLK for each 200A stack. 2 To change in field from ring to ringless—order 1MMRC125. 3 To change in field from ring to ringless, the top socket in 125A, two- and three-high stacks use 1MMRC125T. Top socket only—other sockets see 2. 4 To change in field from ring to ringless—order 1MMRC200. Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 5 5 5 V1-T5-121 5.10 Group Metering Dimensions Approximate Dimensions in Inches (mm) 5 Modular Metering Stacks—Aluminum and Copper 5 1MM, 3MM, 125 Amperes 12.26 (311.4) 2.00 (50.8) TYP. 12.26 (311.4) 30.60 (777.2) 9.00 (228.6) 9.00 (228.6) 9.00 (228.6) 9.00 (228.6) 30.60 (777.2) 3.07 (78.0) 4 Meter Device 2, 3 Meter Device 5 Meter Device 5 5 Tangential K.O.'s 3/4, 1, 1-1/4, 1-1/2 6.06 (153.9) 5 2.83 (71.9) 5 2.83 (71.9) 5 5 6.62 (168.1) 2.83 (71.9) "Z" "Y" "X" 5 5 2.33 (59.1) 5 2.83 (71.9) 2.83 (71.9) 12.13 (308.1) 5 5 5 "Z" = C OF 1-1/2" Ring "Y" = C OF 1-1/4" Ring "X" = C OF 3/4" & 1" Ring L L L 5 2.83 (71.9) 0.125 (3.2) Top End & Bottom End View for NEMA 1; Bottom End View for NEMA 3R Note: Dimensions Apply to 800 and 1200 Ampere Horizontal Bus. 5 V1-T5-122 9.00 (228.6) To C L of Main Busbar 9.00 (228.6) 9.00 (228.6) To C L of Main Busbar 9.00 (228.6) (6) KO for 1, 1-2/4 1-1/2 Conduit 9.00 (228.6) 48.50 (1231.9) 5 7.01 (178.0) 12.60 (320.3) 5 A 30.0 (777.2) 5 41.80 (1061.7) 12.61 (320.2) 5 21.65 (550.0) 5 CL Meter to CL Rail Mounting Screw 5 To CL of Wall Mtg. Screw 5 34.25 (870.0) 5 12.26 (311.4) 9.00 (228.6) This Bus Omitted On 1 — PH Units 9.00 (228.6) 5 57.50 (1460.5) 9.00 (228.6) 12.26 (311.4) 12.60 (320.0) 5 66.50 (1689.1) 9.00 (228.6) 5 12.60 (320.0) 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 6 Meter Device A 30.60 (777.2) To C L of Main Busbar 5 To C L of Main Busbar 5 Metering Products 5.10 Metering Products Group Metering Approximate Dimensions in Inches (mm) 5 Modular Metering Stacks—Aluminum and Copper 5 1MM, 3MM, 200 Amperes 5 13.50 (342.9) 5 1.70 (43.2) TYP. 5 64.50 (1638.3) 7.01 (178.1) (4) KO For 1, 1-1/4, 1-1/2, 2 Conduit 12.12 (307.8) 5 12.12 (307.8) 5 5 30.55 (776.0) To C L of Main Busbar To C L of Main Busbar 5 12.12 (307.8) 12.12 (307.8) 12.12 (307.8) CL Meter to CL Rail Mtg. Screw This Bus Omitted on 1-PH Devices 30.55 (776.0) 18.42 (467.9) 34.25 (870.0) To L C of Wall Rail Mtg. Screw 15.82 (401.8) Circuit Breaker Covers Omitted On NEMA 1 Devices 18.42 (467.9) 52.35 (1329.7) 5 5 5 5 5 1.75 TYP. (44.5) 2, 3 Meter Device 5 5 4 Meter Device 5 5 13.36 (339.3) 6.59 (167.4) 0.12 (3.0) 5 3.38 (85.9) 5 3.00 (76.2) 5 1.76 (44.7) 6.62 (168.1) 5 5 (6) Cocentric K.O.'s 1", 1-1/4", 1-1/2", 2" 3.29 (83.6) 3.29 (83.6) 1.75 (44.5) 5 5 3.29 (83.6) 5 Bottom View 5 Note: Dimensions Apply to 800 and 1200 Ampere Horizontal Bus. 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-123 5.10 Metering Products Group Metering 5 Approximate Dimensions in Inches (mm) 5 5-High, 200 Amperes, 1MM and 3MM Metering 5 1.70 (43.2) 6.87 (174.5) Typ. 5 13.50 (342.9) 5 5 5 12.13 (308.1) 5 5 12.13 (308.1) 5 5 74.96 (1904.0) 12.13 5 (308.1) 5 5 5 5 5 12.13 (308.1) 33.27 (845.1) Typ. to CL of Wall Mtg. Screw 28.88 to CL of Main Busbar 2.74 (69.6) 3.85 (97.8) 5 5 0.45 (11.4) Typ. 5 5 1.87 (47.5) 16.76 (425.7) (5) Concentric K.O.'s 1", 1-1/4", 1-1/2", 2" 1.75 (44.5) 1.61 3.21 (40.9) (81.5) 3.21 (81.5) 3.21 (81.5) Residential Device 13.36 (339.3) 5 0.12 (3.0) 5 6.59 (167.4) 3.38 (85.9) 1.76 (44.7) 6.62 (168.1) 5 5 (6) Cocentric K.O.'s 1", 1-1/4", 1-1/2", 2" 5 5 3.29 (83.6) 3.29 (83.6) 1.75 (44.5) 3.29 (83.6) 5 5 3.00 (76.2) Bottom View Note: The Bussed meter stack device shown on the far right of the figure, must be used on Mains with Busway connections, found on Pages V1-T5-109 and V1-T5-113. Please contact factory for catalog numbers associated with Bussed meter stack devices. 5 V1-T5-124 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Group Metering 5.10 Contents 1MM and 3MM Metering Circuit Breakers Description Page Systems for Residential and Commercial Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type CCV 120/240V Tenant Main Circuit Breaker . Type CV 120/240V Tenant Main Circuit Breaker . . Meter Packs—1MP, 1MM and 3MM Main Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . . Main Service Modules . . . . . . . . . . . . . . . . . . . . . Surge Metering . . . . . . . . . . . . . . . . . . . . . . . . . . . Residential Meter Stacks. . . . . . . . . . . . . . . . . . . . 1MP, 1MM and 3MM Main Tenant Circuit Breakers Phase Balanced Stack . . . . . . . . . . . . . . . . . . . . . . Commercial Meter Stack Modules . . . . . . . . . . . . 35MM, 37MM, 35SS and 37SS Main Tenant Circuit Breakers . . . . . . . . . . . . . . . CV2200 V1-T5-88 V1-T5-90 V1-T5-95 V1-T5-96 V1-T5-98 V1-T5-101 V1-T5-115 V1-T5-116 V1-T5-126 V1-T5-127 V1-T5-134 5 5 5 5 5 5 5 5 5 5 1MP, 1MM and 3MM Main Tenant Circuit Breakers 5 Product Description 5 Specific main tenant circuit breakers that are to be used in meter packs (1MP), residential meter stacks (1MM) and three-phase in single-phase out meter stacks (3MM). 5 5 5 5 Product Selection Description 10 kAIC 22 kAIC 25 kAIC 42 kAIC 65 kAIC 100 kAIC Number of Poles Catalog Number 1 Catalog Number Catalog Number 1234 Catalog Number 234 Catalog Number 234 Catalog Number 234 2 60 BR260 BRH260 — BRHH260 — — 2 70 BR270 BRH270 — BRHH270 — — 2 80 BR280 BRH280 — BRHH280 — — 2 90 BR290 BRH290 — BRHH290 — — 2 100 BR2100 BRH2100 — BRHH2100 — — 2 110 BR2110 BRH2110 — BRHH2110 — — 2 125 BR2125 BRH2125 — BRHH2125 — — 5 5 5 5 5 Bolt-On Type Bolt-on type circuit breakers used with 2 1MP, 1MM, and 3MM 200A modular 2 metering stacks 2 60 — — CVS2060XMM CVS2060XMM CV2060XMM CVH2060XMM 70 — — CVS2070XMM CVS2070XMM CV2070XMM CVH2070XMM 80 — — CVS2080XMM CVS2080XMM CV2080XMM CVH2080XMM 2 90 — — CVS2090XMM CVS2090XMM CV2090XMM CVH2090XMM 2 100 CCV2100X — CCVH2100X CVS2100XMM CV2100XMM CVH2100XMM 2 125 CCV2125X — CCVH2125X CVS2125XMM CV2125XMM CVH2125XMM 2 150 CCV2150X — CCVH2150X CVS2150XMM CV2150XMM CVH2150XMM 2 175 CCV2175X — CCVH2175X CVS2175XMM CV2175XMM CVH2175XMM 2 200 CCV2200X — CCVH2200X CVS2200XMM CV2200XMM CVH2200XMM Notes 1 #2–300 kcmil wire size range for CCV and CCVH tenant main circuit breakers. 2 “MM” suffix indicates mounting hardware kit is included as standard with tenant main breaker. 3 1MMCBK replacement mounting hardware kit. One kit is needed per breaker. Mounting hardware kit ships standard with breaker “MM” suffix offering. 4 #6–4/0 kcmil wire size range for CVS, CV and CVH tenant main circuit breakers. If #2–300 kcmil is needed, order 2TA225CVK. One kit needed per breaker. Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 5 5 Plug-On Type Plug-on type circuit breakers used with 1MP, 1MM, and 3MM 125A modular metering stacks 5 Main Tenant Circuit Breaker Ampere Rating 5 5 5 5 5 5 V1-T5-125 5.10 Metering Products Group Metering Contents 5 Description 5 5 5 5 5 5 5 5 5 5 Phase Balanced Stack 5 Product Description Features Eaton’s Phase Balanced Stack allows for a complete phase balanced metering lineup using fewer stacks. With today’s electrical rooms becoming smaller, the need is greater than ever to offer space-saving metering products while providing a fully phase balanced system. The new phase balanced stack is the answer. ● 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Page Systems for Residential and Commercial Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type CCV 120/240V Tenant Main Circuit Breaker . Type CV 120/240V Tenant Main Circuit Breaker . . Meter Packs—1MP, 1MM and 3MM Main Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . Main Service Modules . . . . . . . . . . . . . . . . . . . . . Surge Metering. . . . . . . . . . . . . . . . . . . . . . . . . . . Residential Meter Stacks . . . . . . . . . . . . . . . . . . . 1MP, 1MM and 3MM Main Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . Phase Balanced Stack Commercial Meter Stack Modules . . . . . . . . . . . . 35MM, 37MM, 35SS and 37SS Main Tenant Circuit Breakers . . . . . . . . . . . . . . . Today, achieving a phase balanced system when connected to a 208Y/120 Vac three-phase, four-wire system may require one or two additional 3MM meter modules. Standard 3MM meter stacks come factory connected to phases A and B. The new phase balanced stacks connect the two bottom meters to phases B and C and the top two or three meters to phases A and C. Using these new stacks with the AB phased 3MM metering, phase balancing is accomplished, and more compact than before. ● ● ● ● ● Available in four- and five-high configurations at 125A 200A stacks available Available with 800A aluminum bus and 1200A copper bus Ring, ringless, ringless with horn bypass available Outdoor enclosure Dimensions same as existing 125A, three-phase meter stacks V1-T5-98 V1-T5-101 V1-T5-115 V1-T5-116 V1-T5-125 V1-T5-127 V1-T5-134 Product Selection Ordering Information ● Check with local utility for height restrictions ● Items loaded in VISTA ● If you have questions, please contact the Technical Resource Center 1-800-356-1243, option 3 Phase Balanced Stack Amperes Per Meter Socket Bus Ampacity Meter Socket Cover Catalog Number 125 800 Ring 3MM412RACBC 125 800 Ring 3MM512RACBC 125 800 Ringless 3MM412RRLACBC 125 800 Ringless 3MM512RRLACBC 125 800 Ringless horn bypass 3MM412RRLBACBC 125 800 Ringless horn bypass 3MM512RRLBACBC 125 1200 Ring 3MM412R2ACBC 125 1200 Ring 3MM512R2ACBC 125 1200 Ringless 3MM412R2RLACBC 125 1200 Ringless 3MM512R2RLACBC 125 1200 Ringless horn bypass 3MM412R2RLBACBC 125 1200 Ringless horn bypass 3MM512R2RLBACBC Note: Local codes and utility requirements still apply. The phase balance stacks are not suitable for changing in the field. 5 5 5 V1-T5-126 V1-T5-88 V1-T5-90 V1-T5-95 V1-T5-96 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Group Metering Commercial Meter Stack Modules (35MM, 37MM, 35SS and 37SS) 5.10 Contents Description 35MM, 37MM, 35SS and 37SS Page Systems for Residential and Commercial Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type CCV 120/240V Tenant Main Circuit Breaker . Type CV 120/240V Tenant Main Circuit Breaker . . Meter Packs—1MP, 1MM and 3MM Main Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . . Main Service Modules . . . . . . . . . . . . . . . . . . . . . Surge Metering . . . . . . . . . . . . . . . . . . . . . . . . . . . Residential Meter Stacks. . . . . . . . . . . . . . . . . . . . 1MP, 1MM and 3MM Main Tenant Circuit Breakers. . . . . . . . . . . . . . . . . . . . . . . . . . Phase Balanced Stack . . . . . . . . . . . . . . . . . . . . . . Commercial Meter Stack Modules 35MM, 37MM, 35SS and 37SS Main Tenant Circuit Breakers . . . . . . . . . . . . . . . V1-T5-88 V1-T5-90 V1-T5-95 V1-T5-96 V1-T5-98 V1-T5-101 V1-T5-115 V1-T5-116 V1-T5-125 V1-T5-126 5 5 5 5 5 5 5 5 5 V1-T5-134 5 Commercial Meter Stack Modules 5 Product Description 5 ● ● ● ● Heavy-duty lever bypass socket design Single-phase or threephase designs (35 = singlephase, 37 = three-phase) Provision for two-pole or three-pole main tenant breakers Phase balance kits are included with three-high and four-high modules Features, Benefits and Functions A. End Walls The top cap is removable and does not contain knockouts, so contractors can position and punch holes where they need them. There are numerous KOs in the back and bottom for flexibility. E. Barrier A solid metal barrier separates the meter socket section from the tenant breaker in the wireway section. The unmetered vertical bus is enclosed to guard against power theft. I. Indoor/Outdoor Construction Raintight caps, meter covers and lockable raintight tenant breaker covers make it convenient for you to use any of our modules on either NEMA 1 or NEMA 3R applications. B. Ground Bars The factory-installed equipment ground bars are provided in both the top and bottom gutters. F. Neutral Assembly Located in the wireway of each module, the assembly permits convenient termination of the neutral conductors. J. Mounting Rail Rear mounting rail and wall hanger speed and simplify installation. (Mounting rail not shown.) C. Meter Socket The 5-jaw meter socket and 7-jaw meter socket includes a built-in manual bypass and jaw release. The ground wire is factory connected in both 35MM and 37MM modules. D. Separate Wireway Cover If work on the breakers or cables is necessary, it can be accomplished without disturbing the meters or meter covers, thanks to a separate cover that allows easy access to the module’s main tenant breaker and wireway section. (Not shown.) G. Enclosed Horizontal Bus Non-removable metal barrier encloses 1200A horizontal bus when passing through the tenant breaker section for added security. H. Tenant Breaker Range All modules accept 15–225A bolt-on breakers in various AIC ratings. The CHH_X breaker carries a UL listed series rating of 100,000A, which allows you to use standard 10 kAIC breakers in downstream loadcenters and panelboards by Eaton. K. Nameplate and Ratings The nameplate gives you full rating data: 208Y/120, threephase, four-wire; 240/120, three-phase, four-wire delta (high leg on B-phase); and 240/120 single-phase. (Not shown.) L. Mains and Modules Slip together quickly, smoothly with frontaccessible captive bolts securing the juncture without removing socket interiors or bus access plate. Main bus joint bolts torque to 25 foot pounds. 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-127 5.10 5 Metering Products Group Metering 37MM Meter Stack Module 5 I 5 H 5 E 5 F ● 5 5 ● ● L C G ● 5 5 5 B 5 A 5 5 5 Eaton’s 35MM and 37MM modular metering stacks contain meter sockets with built-in manual bypass and jaw release (Non-EUSERC areas) Eaton’s 35SS and 37SS stacks use meter sockets with test bypass feature (meets EUSERC electrical requirements) All commercial modular metering stacks contain four horizontal cross buses Mechanically and electrically built to bolt-up with main service modules and residential modular metering stacks Catalog Number Selection Commercial Meter Stack Modules 5 3 7 MM 1 40 R 12 40 K C 5 Bus C = Copper Blank = Aluminum 5 5 Phases Three-phase only 5 Type of Metering MM = Commercial metering module SS = Safety socket—EUSERC 5 5 Number of Meters 1, 2, 3 or 4 5 Socket Type K = K Base bolt-on socket Blank = Plug-in type socket Number of Jaws 5 or 7 Enclosure R = NEMA 3R 5 5 Tenant Breakers 40 = 400A included Blank = Ordered separately Socket Amperage 20 = 200A 40 = 400A 12 AB AC BC Bus = 1200A main bus ampacity = Phases A&B—EUSERC = Phases A&C—EUSERC = Phases B&C—EUSERC When Ordering: 1. Determine catalog number of Main Service Module. 5 2. Determine catalog number of Meter Stack (Residential or Commercial). 5 3. Find quantity and catalog numbers for tenant circuit breakers (found on Page V1-T5-134). Order one breaker per socket. 5 4. If any accessories are needed, order from Pages V1-T5-136 and V1-T5-137. 5 5 5 V1-T5-128 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 5.10 Metering Products Group Metering Product Selection 35MM ● Each socket is a 5 terminal block with lever bypass and jaw release ● Ringless covers ● Provision for two-pole main tenant breakers (circuit breakers not included). For circuit breaker catalog numbers, refer to Page V1-T5-134 5 ● Phase balancing kits are included with three-high and four-high modules. Each individual socket can be phase balanced in the field to the desired lines (A-B, B-C or A-C). Comes from factory as A-B ● ● ● Indoor/outdoor construction Main tenant feeders can exit top, bottom or back If being used in outdoor application and exiting the top, mount Myer type hubs on rainproof cap ● ● Short-circuit ratings up to 100A rms symmetrical depending upon the kAIC rating of installed main tenant circuit breakers and main device Non-EUSERC areas 5 5 5 5 5 5 35MM—Single-Phase Commercial Meter Stack Modules (Three-Phase In, Single-Phase Out) Horizontal Bus Ampacity/ Material Number of Jaws Per Meter Socket Main Tenant Breaker Type (Page V1-T5-134) 1 Bolt-on type EHD2_ CCV2_X CCVH2_X CVS2_XMM CV2_XMM CVH2_XMM 5 System Voltage Ampere Rating Per Meter Socket Number of Meter Sockets 120/240V, single-phase, three-wire systems and 208Y/120V network metering (Not suitable for use on three-phase, four-wire delta systems) 225 1 1200 Al 5 1 1200 Cu 5 2 1200 Al 5 2 1200 Cu 5 3 1200 Al 5 3 1200 Cu 5 35MM320R12C 4 1200 Al 5 35MM420R12 400 400 4 1200 Cu 5 1 1200 Al 5 1 1200 Cu 5 5 Catalog Number 5 35MM120R12 35MM120R12C 5 35MM220R12 5 35MM220R12C 35MM320R12 5 5 35MM420R12C 400A K-Frame included 35MM140R1240C 2 5 5 1200 Al 5 1 1200 Cu 5 2 1200 Al 5 2 1200 Cu 5 400 continuous 1 1200 Cu 5 400A L-Frame included 35MM140R1240K 5 400 continuous 1 1200 Cu 5 400A L-Frame included 35MM140HR1240KC 4 5 400A K-Frame included 35MM140HR1240 3 1 400 400A K-Frame included 35MM140R1240 2 35MM140HR1240C 3 35MM240R1240 35MM240R1240C Notes 1 Retrofit tenant circuit breaker mounting kit (37MMRCBK) for installation of Type EHD and CV breakers. Needed only for stacks manufactured prior to February 2013. Order one kit per breaker. 2 Unit is bottom exit only. 3 Rated at 100 kAIC. 4 Rated at 35 kAIC. 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-129 5.10 5 5 5 5 5 Metering Products Group Metering 37MM ● Each socket is a 7 terminal block with lever bypass and jaw release ● Ringless covers ● Provision for three-pole main tenant breakers (circuit breakers not included). For circuit breaker catalog numbers, refer to Page V1-T5-134 ● ● ● Indoor/outdoor construction Main tenant breakers can exit top, bottom or back If being used in outdoor application and exiting the top, mount Myer type hubs on rainproof cap ● ● Short-circuit ratings up to 100A rms symmetrical depending upon the kAIC rating of installed main tenant circuit breakers and main device Non-EUSERC areas 5 5 5 5 37MM—Three-Phase Commercial Meter Stack Modules (Three-Phase In, Three-Phase Out) System Voltage Ampere Rating Per Meter Socket 208Y/120V, three-phase, four-wire 240/120V, three-phase, four-wire delta (B-phase is high leg) 225 Number of Meter Sockets Horizontal Bus Ampacity/ Material Number of Jaws Per Meter Socket 1 Main Tenant Breaker Type 2 (Page V1-T5-134) Bolt-on type EHD3_ CC3_X CVS3_X CV3_X CVH3_X Catalog Number 1 1200 Al 7 1 1200 Cu 7 2 1200 Al 7 5 2 1200 Cu 7 5 3 1200 Al 7 37MM320R12 3 1200 Cu 7 37MM320R12C 4 1200 Al 7 37MM420R12 4 1200 Cu 7 1 1200 Al 7 1 1200 Cu 7 1200 Al 7 5 5 5 400 37MM120R12 37MM120R12C 37MM220R12 37MM220R12C 37MM420R12C 400A K-Frame included 37MM140R12 3 400A K-Frame included 37MM140R1240 4 400A K-Frame included 37MM140HR1240 5 400A K-Frame included 37MM240R1240 37MM140R12C 3 5 400 1 5 1 1200 Cu 7 400 1 1200 Al 7 5 1 1200 Cu 7 400 2 1200 Al 7 5 2 1200 Cu 7 400 continuous 1 1200 Cu 7 37MM140R1240KC 6 5 400A L-Frame included 400 continuous 1 1200 Cu 7 400A L-Frame included 37MM140HR1240KC 7 5 5 5 5 37MM140R1240C 4 37MM140HR1240C 5 37MM240R1240C Notes 1 If a socket in a 37MM meter stack module needs to be single-phase, order 37MM1CK. This will convert the three-phase socket to single-phase. 2 Retrofit tenant circuit breaker mounting kit (37MMRCBK) for installation of Type EHD and CV breakers. Needed only for stacks manufactured prior to February 2013. Order one kit per breaker. 3 320A continuous rated socket with provisions for two main tenant breakers. 4 Unit is bottom exit only. 5 Rated at 100 kAIC. 6 Rated at 25 kAIC. 7 Rated at 35 kAIC. 5 5 5 5 5 5 5 V1-T5-130 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Group Metering 35SS ● Sockets include EUSERC required test-bypassdisconnect feature ● Ring type covers ● Single-phase units have provisions for two-pole main tenant breakers 35SS_ When applying 35SS (single-phase) stacks on 208Y/120V, three-phase, four-wire and 240/120V, three-phase, four-wire delta systems, refer to suffixes for proper phase balancing. Each meter stack module is phase balanced at the plant (A-B, B-C or A-C) and cannot be field modified ● ● ● Indoor/outdoor construction Main tenant breakers can exit top, bottom or back. If being used in outdoor application and exiting the top, mount Myer type hubs on rainproof cap ● 5.10 Short-circuit ratings up to 100A rms symmetrical depending upon the kAIC rating of installed main tenant circuit breakers and main device 5 5 5 5 5 5 35SS—Three-Phase Commercial Meter Stack Modules 5 System Voltage Ampere Rating Per Meter Socket Number of Meter Sockets Horizontal Bus Ampacity/ Material 120/240V, single-phase, three-wire systems and 208Y/120V network metering (Not suitable for use on three-phase, four-wire delta systems) 225 1 1200 Al 5 1200 Cu 5 1200 Al 5 1200 Cu 5 1200 Al 5 1200 Cu 5 35SS120RBCC 2 1200 Al 5 35SS220RAB 2 1200 Cu 5 35SS220RABC 2 1200 Al 5 35SS220RAC 2 1200 Cu 5 35SS220RACC 2 2 3 37SS ● Sockets include EUSERC required test-bypassdisconnect feature ● Ring type covers 5 Number of Jaws Per Meter Socket Main Tenant Breaker Type 1 (Page V1-T5-134) Bolt-on type EHD2_ CCV2_X CCVH2_X CVS2_X CV2_X CVH2_X Catalog Number 35SS120RAB 2 35SS120RABC 2 35SS120RAC 2 35SS120RACC 2 35SS120RBC 2 2 1200 Al 5 35SS220RBC 1200 Cu 5 35SS220RBCC 2 2 1200 Al 5 35SS320RAB 1200 Cu 5 35SS320RABC 2 1200 Al 5 35SS320RAC 2 1200 Cu 5 35SS320RACC 2 2 1200 Al 5 35SS320RBC 1200 Cu 5 35SS320RBCC 2 5 5 5 5 5 5 5 5 5 5 5 Three-phase units have provisions for three-pole main tenant breaker ● ● 5 Aluminum horizontal bus supplied as standard 5 5 37SS—Three-Phase Commercial Meter Stack Modules System Voltage Ampere Rating Per Meter Socket Number of Meter Sockets Horizontal Bus Ampacity/ Material 208Y/120V, three-phase, four-wire 240/120V, three-phase, four-wire delta (B-phase is high leg) 225 1 1200 Al 7 1200 Cu 7 1200 Al 7 1200 Cu 7 1200 Al 7 1200 Cu 7 2 3 Number of Jaws Per Meter Socket Main Tenant Breaker Type 1 (Page V1-T5-134) Bolt-on type EHD3_ CC3_X CVS3_X CV3_X CVH3_X Catalog Number 37SS120R 37SS120RC 37SS220R 37SS220RC 37SS320R 37SS320RC Notes 1 Retrofit tenant circuit breaker mounting kit (37MMRCBK) for installation of Type EHD and CV breakers. Needed only for stacks manufactured prior to February 2013. Order one kit per breaker. 2 Last two digits of catalog number indicate phase balancing (AB indicates all sockets in this stack are connected to phases A and B only). 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-131 5.10 5 Metering Products Group Metering Approximate Dimensions in Inches (mm) 5 Commercial Stacks (35MM and 37MM) 5 35MM and 37MM 35MM140R1240 37MM140R1240 same as below except eliminate top socket. 5 5 5 5 5 14.00 (355.6) Typ. 5 5 52.63 (1336.7) 25.38 (644.5) 52.63 (1336.7) 66.63 (1692.3) 5 5 5 5 5 8.75 (222.3) 8.75 (222.3) 5 18.25 (463.6) 5 18.25 (463.6) 18.25 (463.6) 5 5 5 5 5 5 5 5 5 5 5 5 5 V1-T5-132 8.75 (222.3) 8.75 (222.3) Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 19.25 (489.0) Metering Products Group Metering 5.10 Approximate Dimensions in Inches (mm) 5 Commercial Stacks (35SS and 37SS) 5 35SS and 37SS 21.38 (542.9) 12.00 (304.8) 21.38 (542.9) 12.00 (304.8) 29.38 (746.1) 9.56 (242.9) 19.50 (495.3) 17.75 (450.9) Centerline 19.50 (495.3) of Wall Mounting Screws 25.00 (635.0) 13.50 (342.9) 2.00 (50.8), 2.50 (63.5) 43.00 (1092.2) 5 5 19.50 (495.3) 31.50 (800.1) 47.38 (1203.3) 5 5 68.88 (1749.4) KO 1.50 (38.1) 5 5 62.44 (1585.9) 6.50 (165.1) 6.50 (165.1) 6.50 (165.1) 0.41 Dia. 9.56 (10.3) (242.9) 4-Holes 5 21.38 (542.9) 12.00 (304.8) 9.50 (241.3) 5 5 31.50 (800.1) 5 5 5 5 Wire Seal Slot and Sealing Screw Ribbon Seal or Barrel Lock Hasp 8.75 Bottom (Typ.) 13.56 (222.3) (344.5) Inside 5 3 KOs 1.50 (38.1), 2.00 (50.8), 2.50 (63.5) 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-133 5.10 5 Metering Products Group Metering 35MM, 37MM, 35SS and 37SS Main Tenant Circuit Breakers Description 5 5 5 5 5 5 5 5 CV2200/CV3200 5 5 5 5 5 5 5 5 5 5 Contents Systems for Residential and Commercial Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type CCV 120/240V Tenant Main Circuit Breaker . Type CV 120/240V Tenant Main Circuit Breaker . . Meter Packs—1MP, 1MM and 3MM Main Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . Main Service Modules . . . . . . . . . . . . . . . . . . . . . Surge Metering. . . . . . . . . . . . . . . . . . . . . . . . . . . Residential Meter Stacks . . . . . . . . . . . . . . . . . . . 1MP, 1MM and 3MM Main Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . Phase Balanced Stack. . . . . . . . . . . . . . . . . . . . . . Commercial Meter Stack Modules . . . . . . . . . . . . 35MM, 37MM, 35SS and 37SS Main Tenant Circuit Breakers 35MM, 37MM, 35SS and 37SS Main Tenant Circuit Breakers Product Description ● ● ● ● The following breakers are to be used on 35MM, 37MM, 35SS and 37SS modular metering stacks Series rating information available on Pages V1-T5142 through V1-T5-145 Two-pole breakers are 120/240 Vac, field installed Three-pole breakers are 208Y/120 Vac, field installed 5 5 5 5 5 5 5 5 5 5 5 V1-T5-134 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Page V1-T5-88 V1-T5-90 V1-T5-95 V1-T5-96 V1-T5-98 V1-T5-101 V1-T5-115 V1-T5-116 V1-T5-125 V1-T5-126 V1-T5-127 Metering Products Group Metering 5.10 Product Selection 5 5 35MM, 37MM, 35SS and 37SS Main Tenant Circuit Breakers 10 kAIC 25 kAIC 42 kAIC 65 kAIC 100 kAIC Main Tenant Circuit Breaker Ampere Rating 5 Catalog Number Catalog Number 12 Catalog Number 12 Catalog Number 12 Catalog Number 12 5 Bolt-on type circuit breakers used 2 with 35MM and 35SS (single-phase 2 modular metering stacks) 34 2 60 EHD2060 CVS2060XMM CVS2060XMM CV2060XMM CVH2060XMM 70 EHD2070 CVS2070XMM CVS2070XMM CV2070XMM CVH2070XMM 80 EHD2080 CVS2080XMM CVS2080XMM CV2080XMM CVH2080XMM 2 90 EHD2090 CVS2090XMM CVS2090XMM CV2090XMM CVH2090XMM 2 100 CCV2100X CCVH2100X CVS2100XMM CV2100XMM CVH2100XMM 2 125 CCV2125X CCVH2125X CVS2125XMM CV2125XMM CVH2125XMM 2 150 CCV2150X CCVH2150X CVS2150XMM CV2150XMM CVH2150XMM 2 175 CCV2175X CCVH2175X CVS2175XMM CV2175XMM CVH2175XMM 2 200 CCV2200X CCVH2200X CVS2200XMM CV2200XMM CVH2200XMM 2 225 CCV2225X CCVH2225X CVS2225XMM CV2225XMM CVH2225XMM 3 Bolt-on type circuit breakers used with 37MM and 37SS (three-phase 3 34 modular metering stacks) 3 60 EHD3060 CVS3060X CVS3060X CV3060X CVH3060X 70 EHD3070 CVS3070X CVS3070X CV3070X CVH3070X 80 EHD3080 CVS3080X CVS3080X CV3080X CVH3080X 3 90 EHD3090 CVS3090X CVS3090X CV3090X CVH3090X 3 100 CC3100X CVS3100X CVS3100X CV3100X CVH3100X 3 125 CC3125X CVS3125X CVS3125X CV3125X CVH3125X 3 150 CC3150X CVS3150X CVS3150X CV3150X CVH3150X 3 175 CC3175X CVS3175X CVS3175X CV3175X CVH3175X 3 200 CC3200X CVS3200X CVS3200X CV3200X CVH3200X 3 225 CC3225X CVS3225X CVS3225X CV3225X CVH3225X Description Number of Poles Bolt-On Type Bolt-On Type Notes 1 #6–4/0 kcmil wire size range for CVS, CV and CVH tenant main circuit breakers. If #2–300 kcmil is needed, order 2TA225CVK (two-pole) 3TA225CVK (three-pole). One kit is needed per breaker. 2 “MM” suffix provides mounting hardware needed for 1MP, 1MM and 3MM modular metering stacks only. Mounting hardware is not needed for use in 35MM and 35SS modular metering stacks, but is included as standard with breakers. 3 Retrofit tenant circuit breaker mounting kit (37MMRCBK) for installation of Type EHD and CV breakers. Needed only for stacks manufactured prior to February 2013. Order one kit per breaker. 4 Type EHD main tenant circuit breakers are also available from 15 to 50A. 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-135 5.10 5 Metering Products Group Metering Accessories 5 1MP, 1MM and 3MM Modular Metering Stacks 5 Description Application Fifth jaw kit Bolted onto neutral in the 3, 6 or 9 o’clock position. Typically used on network metering systems (three-phase in/single-phase out) or when specified by utility company. 1MM5JK Isolated fifth jaw kit Connects to the neutral with an insolated wire. 1MM5JKOP Manual bypass kit (ring style socket only) For use with 125A sockets only. (Not top socket.) 1MMBPM125 For use with 200A sockets only. (Not top socket.) 1MMBPM200 1MMBPM125T 5 This kit only to be used for top position of two- and three-high 125A 1MM and 3MM stacks and of 2, 5 and six-position 125A 1MP packs. 5 This kit only to be used for top position of 200A two-position 1MP packs. 1MMBPM200T Used only on ringless cover stacks, kits can be installed on 125A or 200A sockets. 1MMBPH 5 Fifth Jaw Kit 5 5 5 Manual Bypass Kit 5 5 5 Horn Bypass Kit Horn bypass 5 5 Note: For 1MP2122RRL use: WCG8HB 1 Meter bypass jumper Installed on 125A or 200A sockets. Jumpers are plugged into jaws. Order Lexan® cover plate with bypass jumpers to prevent access to meter socket once energized. (Not UL listed.) 1MMBPJ Lexan blank cover Circular cover mounted on ring or ringless devices preventing access to meter socket while meter is not in place. Includes four plastic tabs that plug into each jaw. 1MMPCP Same as 1MMPCP minus the tabs located in the back to plug into jaws. This device to be used while meter bypass jumpers are in place (1MMBPJ). 1MMACP Used for 125A stacks. Fits bottom socket only. Kit replaces existing meter cover preventing access to meter socket. Includes hasp for seal. 1MMBC125B Used on 200A stacks. Fits bottom socket only. Kit replaces existing meter cover preventing access to meter socket. Includes hasp for seal. 1MMBC200B 5 5 Lexan Blank Cover 5 5 5 Blank meter socket cover 5 5 5 5 5 Catalog Number Wall Mounting Rail Wall mounting rail Rails are 4 feet (1.2m) in length. Bolted on wall for stacks, packs and mains to be hung. 1MMWB Bussed Spacer Bussed spacer Bussed spacer 1200A 4-inch (101.6 mm). Required when stacks are mounted on right-hand side in EUSERC areas. (copper) 3MMBSK 2 Bus duct riser/ meter center connection Available in 400, 600, 800A main fusible units only. Contact product line for details. — 5 5 5 5 5 Notes 1 WCG8HB only applies to meter packs built prior to 1998. Current meter packs use 1MMBPH. 2 Must be used when mounting MCB main next to an MTB main or another MCB main device. 5 V1-T5-136 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Group Metering 5.10 Accessories for 1MP, 1MM and 3MM Modular Metering Stacks, continued Indoor Corner Elbow Application Indoor corner elbow (copper) 12-inch (304.8 mm) indoor corner elbow, 1200A, three-phase, four-wire for use with 1MM and 3MM only. Do not use with 35MM, 37MM, 35SS or 37SS stacks. 12-inch corner elbow not EUSERC approved. 3MMEB12 Indoor corner elbow (copper) 16-inch (406.4 mm) indoor corner elbow, 1200A, three-phase, four-wire for use with 1MM, 3MM, 35MM, 37MM, 35SS and 37SS. 3MMEB16 Barrier Barrier for individual sockets 1MMBK Meter jumper and cover Combination meter jumper and cover (200A maximum). Used to jumper line and load jaws as well as cover meter socket preventing exposure to current carrying parts. 1MMJCK 125A two-pole lug block assembly. BRSF125 Lug block Standard Sealing Ring Sealing ring Top endwall 5 Catalog Number Description 5 5 5 5 5 5 5 Stainless steel screw type with brass screw 1MMSR1 Standard (included with packs and stacks) 1 1MMSR2 Stainless steel screw type with cast zinc screw 1MMSR4 Aluminum screw type with locking provisions 1MMSR5 125A, NEMA 1 top end wall with knockouts for 1MM, 3MM meter stacks MM12N1WLK 200A, NEMA 1 top end wall for 1MM, 3MM meter stacks MM20N1WLK 5 5 5 5 5 5 5 Note 1 Aluminum Snap Type. 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-137 5.10 5 Metering Products Group Metering Renewal Parts 5 1MP, 1MM and 3MM Replacement Parts 5 Description Application Ringless cover (can install this to go from ring to ringless) Installed on 125A socket for ringless security 1MMRC125 Installed on 200A socket for ringless security 1MMRC200 For use with top position of 125A, two- and three-position,1MM and 3MM stacks and two-, five- and six-position 1MP packs 1MMRC125T Top-position two position IMP 1MMRC200T Installed on 125A socket for ring security 1MMCP1 Installed on 200A socket for ring security 1MMCP2 5 Top socket ring cover 125A 1MMCP1T 5 Top socket ring cover 200A 1MMCP2T 125A cover 1MMBC1 200A cover 1MMBC2 125 and 200A 1MMMS Flat—left side 47-24139A Bump—right side 47-28172-2A 5 Ringless Cover 5 5 5 5 5 Ring Cover Ring cover 5 5 Tenent Breaker Cover 5 Tenant breaker hinged cover 5 5 5 Meter Socket Meter socket 1 Catalog Number 5 5 5 Busbar end cap 5 Main circuit breaker cover kit (black) 5 49-7060 5 5 Notes 1 Meter Packs 1MP2122RRL and 1MP2122RRLB use different meter sockets. See Renewal Parts listing RP.32A.01A.T.E for details. 5 See RP00501001E for a complete Renewal Parts listing. 5 5 5 5 5 V1-T5-138 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Group Metering 5.10 Accessories for 35MM and 37MM Modular Metering Stacks 5 Catalog Number Description Application Wall mounting rail Rails are 4 feet (1.2m) in length. Bolted on wall for stacks, packs and mains to be hung. 1MMWB 5 Indoor corner elbow (copper) 16-inch (406.4 mm) indoor corner elbow, 1200A, three-phase, four-wire for use with 1MM, 3MM, 35MM, 37MM, 35SS and 37SS. 3MMEB16 5 Handle insulator Each meter block includes a lever bypass. This kit includes the sleeve which slides onto the lever handle. 37MMHC 5 Needed when using barrel lock security. 37MMBLK 5 Barrel Lock Bracket Kit Barrel lock bracket kit 5 5 5 Totalizing Jumper Kit Totalizing jumper kit Used if one socket is to meter two tenant feeds. When ordering jumper kit, should also order a plastic cover plate (1MMPCP + IMMJCK) preventing access to live parts on unused socket. 5 37MMTJK 5 5 Type EHD and CV Breaker Retrofit Mounting Kit Type EHD and CV breaker retrofit mounting kit Retrofit mounting hardware for installation of Type EHD and CV breakers in 35MM, 37SS, 37MM and 37SS meter stacks manufactured prior to February 2013. Order one kit per breaker. 5 37MMRCBK 5 5 Type CV Breaker Mounting Kit Type CV breaker mounting kit Replacement Type CV breaker mounting hardware kit. Used in 200A 1MP/1MM/3MM modular metering stacks at 42, 65 and 100 kAIC. 5 1MMCBK 5 5 5 Blank Cover Kit Blank cover kit Kit replaces meter cover preventing access to socket. 37MMCK 1 5 5 37MMCKA 2 5 Three-Phase to Single-Phase Conversion Kit Barrier Barrier for individual sockets 37MMBK Three-Phase to single-phase conversion kit This kit will convert one three-phase meter socket (37MM devices) to a single-phase socket. Only needed if phasing A-C or C-B. If single-phase socket is to be phased A-B, kit is not required for field conversion. (Must use three-phase breaker.) 37MM1CK 5 5 5 5 5 Bus duct riser/meter center connection Available in 400, 600, 800A Main fusible units and 400, 600, 800, 1000, 1200 main circuit breaker. Contact product line for details. — Anti-inversion clip This clip should be inserted into upper right hand jaw of a 320A meter socket. The purpose is prevent a 200A meter from being inserted into a 320A meter socket. 37MMINVCLIP 5 5 5 Notes 1 For all units made 10/2002 and earlier. 2 For all units made after 11/2002. Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 5 V1-T5-139 5.10 5 Metering Products Group Metering Renewal Parts 5 35MM and 37MM Modular Metering Stacks 5 Description Application 35MM replacement meter socket To replace meter socket with lever bypass and jaw release. MSLMSA1 37MM replacement meter socket To replace meter socket with lever bypass and jaw release. MSLMSA2 35SS replacement meter socket To replace meter socket with test bypass disconnect feature MSTMSA1 37SS replacement meter socket To replace meter socket with test bypass disconnect feature MSTMSA2 5 Safety socket meter cover assembly To replace ring type cover over the meter prior to 7/1/02. MSTMCVR1 5 Safety socket meter cover assembly To replace ring type cover over the meter after 7/1/02 MSTMCVR1E 35MM and 37MM meter cover assembly Prior to 12/1/02 37MMSK After 12/1/02 37MMSK1 To replace ringless cover over the meter. Includes New Jersey latch requirement. 37MMSKNJ 5 35MM Replacement Meter Socket 5 Catalog Number 5 5 5 5 37SS Replacement Meter Socket 5 5 5 Meter Cover Assembly 5 5 5 Meter cover assembly with NJ latch 5 5 Tenant breaker hinged cover To replace cover over tenant breakers. 1MMBC2 Busbar end cap Flat—left side 47-24139A Bump—right side 47-28172-2A Main circuit breaker cover/CIT (black) 5 49-7060 Note See RP.32A.01.T.E for a complete Renewal Parts listing. 5 5 5 5 5 5 5 5 5 5 V1-T5-140 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 5.10 Metering Products Group Metering Technical Data and Specifications 5 Phase Balancing 125 A STACKS N A A A A 5 B B B B 5 C C C C 5 N 5 A B B "Z" Shaped Phase Connector 5 "Z" Shaped Phase Connector FACTORY 125 A A-B PHASING 5 FACTORY 200 A A-B PHASING N N N FIGURE B 5 A A A A 5 B B B B 5 C C C 5 C C "Barrel" Shaped Phase Connector FIELD 125 A A-C PHASING Remove "Z" Phase Jumper from "B" Phase Horizontal Bus Replace with "Barrel" Phase Jumper from kit 99-4184 Supplied with Meter Stack and attach to "C" Phase Bus as shown. Torque to 60 lb-in (6.78 N-M) Retain "Z" Phase Jumper for future use. FIGURE C N A A “Z” Shaped and “Barrel” Shaped Phase Connector 5 "Barrel" Shaped Phase Connector "Barrel" Shaped Phase Connector 16 Total Positions—use (two) five-position and (two) three-position stacks. Phase balance (one) five-position per Figure B (A-C phasing) and (one) five-position per Figure C (C-B phasing). 5 C 5 "Z" Shaped Phase Connector FACTORY 200 A A-C PHASING 5 Remove "Z" Phase Jumper from "B" Phase Horizontal Bus Reattached at "C" Phase Horizontal Bus as Shown. Torque to 60 lb-in (6.78 N-M) 5 5 N N N N 5 A A A A 5 B B B B 5 C C C 5 C C "Barrel" Shaped Phase Connector B C B 5 "Z" Shaped Phase Connector FIELD 125 A C-B PHASING Remove "Barrel" Phase Jumper from "A" Phase Horizontal Bus Reattached at "C" Phase Horizontal Bus as shown. Torque to 60 lb-in (6.78 N-M) "Barrel" Shaped Phase Connector 5 N A Nine Total Positions—use (three) three-position stacks and phase one per Figure B (A-C phasing) and one per Figure C (C-B phasing). "Z" Shaped Phase Connector "Barrel" Shaped Phase Connector N Examples: 19 Total Positions—where four-position maximum height is allowed by utility. Use (one) four-position and (five) three-position stacks. Phase balance (two) threeposition stacks per Figure B (A-C phasing) and (two) three-position stacks per Figure C (C-B phasing). 5 200 A STACKS "Barrel" Shaped Phase Connector FIGURE A Phase Balancing All 3MM meter modules come factory connected to phase A and B, per Figure A. When connected to a 208Y/120 Vac three-phase, four-wire system, field phase balancing of two out of every three stacks is required. One of every three stacks should be phased AC, per Figure B, and one of every three stacks should be phased CB, per Figure C. 5 "Barrel" Shaped Phase Connector 5 "Z" Shaped Phase Connector 5 FACTORY 200 A C-B PHASING Remove "Barrel" Phase Jumper from "A" Phase Horizontal Bus Reattached at "C" Phase Horizontal Bus as shown. Torque to 60 lb-in (6.78 N-M) 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-141 5.10 5 5 5 5 5 5 5 5 5 5 Metering Products Group Metering Series Combination Short-Circuit Ratings When main tenant breakers are installed in Eaton’s modular metering stack per the table on Page V1-T5-143, the branch breakers installed in downstream panel rated 10 kAIC or greater are protected to the listed series AIC rating. Refer to the downstream panel marking for the proper series combination shortcircuit ratings. Series Combination Short-Circuit Ratings The Watt-Hour Meter is not Included in the Short-Circuit Current Rating (Per UL 67). Downstream Panel (Type CH or BR) Main Tenant Breaker Main Modular Service Metering Module Stack Load Side Breakers Replacement or additional breakers shall be of the same manufacture and type, and shall have an interrupting rating equal to or greater than the interrupting rating of any main tenant breaker installed. 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 V1-T5-142 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Group Metering 5.10 Series Combination Short-Circuit Ratings—240 Vac 5 Main Module Overcurrent Device Breaker Type or Class Fuse System AIC Rating 120/240 Vac Maximum Meter Module Tenant Feeder Breaker Type 1MM, 3MM, 35MM, 37MM, 35SS, 37SS or Loadcenter Main Breaker Tenant Feeder Breaker ShortCircuit Rating Loadcenter Branch Breaker (Single-, Two- or Three-Pole) None 10,000 None — BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI Without main disconnect. Cable tap box Type 1MTB_, 3MTB_ 10,000 BR_, CC_, BW_, CCV_ 10,000 22,000 BRH_ 22,000 25,000 CSR_, CHH_H2, CCVH_ 25,000 42,000 BRHH_, CHH_H4, CVS_ 42,000 65,000 CV_, KD_, HKD_ 65,000 5 5 5 5 100,000 CHH_, CVH_, KDC_ 100,000 Main switch module Type 1MFS_, 3MFS_ with Class T fuse, 400A maximum 42,000 BRH_ 22,000 CH, CHT, CH3, CH-GFCI Main switch module Type 1MFS_, 3MFS_ with Class T fuse, 600A maximum 100,000 BRH_ 22,000 BD, BR, BRD, BQ, BQC, GFCB Main switch module Type 1MFS_, 3MFS_ with Class T fuse, 1200A maximum 10,000 BR_, CC_, BW_, CCV_ 10,000 BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI 22,000 BRH_ 22,000 25,000 CSR_, CHH_H2, CCVH_ 25,000 42,000 BRHH_, CHH_H4, CVS_ 42,000 65,000 CV_, KD_, HKD_ 65,000 100,000 CHH_, CVH_, KDC_ 100,000 Main switch module Type 1MFS_, 3MFS_ with Class T fuse, 1200A maximum 100,000 BRHH_ 42,000 BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI Main switch module Type 1BPS_, 3BPS_ with Class L fuse, 1200–2000A 10,000 BR_, CC_, BW_, CCV_ 10,000 BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI 22,000 BRH_ 22,000 25,000 CSR_, CHH_H2, CCVH_ 25,000 42,000 BRHH_, CHH_H4, CVS_ 42,000 65,000 CV_, KD_, HKD_ 65,000 100,000 CHH, CVH_, KDC_ 100,000 10,000 BR_, CC_, BW_, CCV_ 10,000 22,000 BRH_ 22,000 25,000 CSR_, CHH_H2, CCVH_ 25,000 Main breaker module Type 1MCB_, 3MCB_ with KD, HKD (400A maximum) LD, HLD (600A maximum) MDL, HMDL (800A maximum) ND, NGS, HND, NGH (1200A maximum) RD, RGH (2000A maximum) 5 5 5 5 5 5 5 5 5 5 42,000 BRHH_, CHH_H4, CVS_ 42,000 65,000 CV_, KD_, HKD_ 65,000 100,000 1 CHH_, CVH_, KDC_ 100,000 5 5 5 5 BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI 5 5 5 5 Note 1 100,000A rating with 100,000A rated main. 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-143 5.10 Metering Products Group Metering 5 1MP 125A Meter Module This All-in-One Meter Module is UL listed for the short-circuit rating at 240 Vac maximum in rms symmetrical amperes per table below. 5 1MP 125A Meter Module 5 Tenant Breaker Catalog Number Two-Pole 5 5 5 5 5 5 5 5 1MP 200A Meter Module Tenant Breaker Catalog Number Two- or Three-Pole Maximum Ampere Rating UL Listed Series Short-Circuit Rating Maximum Ampere Rating UL Listed Series Short-Circuit Rating CVH_XMM 200 100 kAIC BRHH_____ 125 42 kAIC CV_XMM 200 65 kAIC BRH_____ 125 22 kAIC CVS_XMM 200 42 kAIC BR_____ 125 10 kAIC CCVH_XMM 200 25 kAIC CCV_X 200 10 kAIC When Type BRHH or BRH tenant breakers are installed in this meter module, then Eaton’s breakers rated 10 kAIC or greater installed on the load side of this meter module may be protected for short circuits up to 22 kAIC with Type BRH breakers or 42 kAIC with Type BRHH breakers. When Type CV tenant breakers are installed in this meter module, then breakers rated 10 kAIC or greater installed on the load side of this meter module may be protected for short circuits up to 100 kAIC. See load side breaker panel marking for proper short-circuit current rating. See load side breaker panel marking for proper short-circuit current rating. 1MP 125A Meter Module 1MP 200A Meter Module The Watt-Hour Meter is not Included in the Short-Circuit Current Rating (Per UL 67). 5 5 5 This All-in-One Meter Module is UL listed for the short-circuit rating at 240 Vac maximum in rms symmetrical amperes per table below. All-in-One Meter Module 5 Downstream Panel (Type CH or BR) Tenant Breaker 5 The Watt-Hour Meter is not Included in the Short-Circuit Current Rating (Per UL 67). All-in-One Meter Module Downstream Panel (Type CH or BR) Tenant Breaker Load Side Breakers 5 1MP 200A Meter Module 5 Note: The ratings for both 125 and 200A tenant positions apply to both Type BR and CH loadcenters and 10 kAIC branch breakers. 5 5 5 5 5 5 5 5 5 5 5 5 V1-T5-144 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Load Side Breakers 5.10 Metering Products Group Metering General When tenant breakers are installed in Eaton’s metering modules per the short-circuit current ratings below, the branch breakers installed in downstream panel rated 10 kAIC or greater are protected to the listed series AIC rating. Refer to the downstream panel marking for the proper series combination short-circuit ratings. These ratings apply to both loadcenter Types BR and CH. The short-circuit rating is limited to the lowest interrupting rating of any tenant breaker installed or to the lowest marked interrupting rating of the main switch, main breaker or main lug modules. Replacement or additional breakers shall be of the same type and manufacturer, and shall have an interrupting rating equal to or greater than the interrupting rating of any tenant breaker presently installed in the meter module. 1MM, 3MM 125A Meter Module When used with main switch, main breaker or main lug modules, this meter module is UL listed for the short-circuit rating at 240 Vac maximum in rms symmetrical amperes per table below. 1MM, 3MM 125A Meter Module Tenant Breaker Catalog Number Two-Pole Amperes Maximum UL Listed Series Short-Circuit Rating BRHH_____ 125 42 kAIC BRH_____ 125 22 kAIC BR_____ 125 10 kAIC When Type BRHH or BRH tenant breakers are installed in this meter module, then breakers rated 10 kAIC or greater installed on the load side of this meter module may be protected for short circuits up to 22 kAIC with Type BRH breakers or 42 kAIC with Type BRHH breakers. 1MM, 3MM, 200A Meter Modules; 35MM, 37MM, 35SS and 37SS 225A Meter Modules When used with main switch, main breaker or main lug modules, these meter modules are UL listed for the short-circuit rating at 240 Vac maximum in rms symmetrical amperes per table below. 5 1MM, 3MM, 200A Meter Modules; 35MM, 37MM, 35SS and 37SS 225A Meter Modules 5 Amperes Maximum Tenant Breaker Catalog Number Two- or Three-Pole 1MM 3MM 200A 35MM, 37MM, 35SS, 37SS UL Listed Series 225A Short-Circuit Rating CVH_XMM 200 225 100 kAIC CV_XMM 200 225 65 kAIC CVS_XMM 200 225 42 kAIC CCVH_X 200 225 25 kAIC CCV_X 200 225 10 kAIC CC_X 200 225 10 kAIC 5 5 1MM, 3MM, 200A Meter Modules; 35MM, 37MM, 35SS and 37SS 225A Meter Modules 5 5 5 5 5 5 The Watt-Hour Meter is not Included in the Short-Circuit Current Rating (Per UL 67). 5 Downstream Panel (Type CH or BR) 5 Main Tenant Breaker 5 5 Load Side Breakers 5 The Watt-Hour Meter is not Included in the Short-Circuit Current Rating (Per UL 67). 5 Downstream Panel (Type CH or BR) 5 Main Tenant Breaker Main Modular Service Metering Module Stack 5 5 See load side breaker panel marking for proper short-circuit current rating. Main Modular Service Metering Module Stack 1MM, 3MM 125A Meter Module 5 5 When Type CV tenant breakers are installed in these meter modules, then Eaton’s breakers rated 10 kAIC or greater installed on the load side of these meter modules may be protected for short circuits up to 100 kAIC. See load side breaker panel marking for proper short-circuit current rating. 5 5 5 Load Side Breakers 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-145 5.10 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Metering Products Group Metering Ratings A. The assembly shall be rated to withstand mechanical forces exerted during shortcircuit conditions when connected directly to a power source having available fault current [22,000] [42,000] [65,000] [100,000] amperes symmetrical at rated voltage. Construction A. The entire assembly shall be front accessible and shall include [main lugs] [a main disconnect device]. B. Tenant disconnects shall be wired for cold sequence and shall be molded case circuit breakers. C. The meter sockets shall be (ring-) (ringless-) type rated (125A) (200A) (as shown on the plans) and a bypass (shall be) (shall not be) required. If required, the bypass shall be a (slider-) (horn-) (lever-) (disconnect block-) type. The meter sockets and associated branch protective device positions shall be completely prewired and shipped ready for installation of the meters and tenant main breakers. Meter sockets shall include covers with sealing positions. Bus A. All busbars shall be [tinplated aluminum or copper]. Main horizontal busbars shall be mounted with all three phases arranged in the same vertical plane. Bus sizing shall be based on UL standard temperature rise criteria for multiple metering equipment. B. Provide a full capacity neutral bus where a neutral bus is indicated on the drawings. C. All hardware used for busbar connections shall be high-tensile strength, zinc-plated. Provide Belleville-type spring washers for all bus joints. Wiring/Terminations A. [Mechanical-type terminals] [Crimp-type termination provisions] shall be provided for all line terminations suitable for copper or aluminum cable and rated at 75ºC. B. Lugs shall be provided in the incoming line section for connection of the main grounding conductor. Main Circuit Protective Devices A. Main protective devices shall be [molded case circuit breakers] [bolted pressure switches] [quickmake/quick-break fusible switches]. Molded Case Circuit Breakers A. [Main] [Feeder] [All] protective devices shall be molded case circuit breakers with inverse time and instantaneous tripping characteristics. B. Circuit breakers shall be operated by a toggle-type handle and shall have a quick-make/quick-break over-center switching mechanism that is mechanically trip-free. Automatic tripping of the breaker shall be clearly indicated by the handle position. Contacts shall be nonwelding silver alloy and arc extension shall be accomplished by means of DE-ION® arc chutes. C. Circuit breakers shall have a minimum symmetrical interrupting capacity as indicated on the drawings. D. Circuit breakers [250-] [400-] [600-] [1200-] ampere frame and below shall be manufactured by Eaton with thermalmagnetic or electronic trip units having inverse time-current characteristics. E. Circuit breakers shall be UL listed for series application. Bolted Pressure Switches A. Main protective devices shall be bolted pressure contact type and shall be UL listed. B. Fusible switches shall be furnished with Class L fuse clips. Switch contact interrupting capacity shall be 12 times the continuous rating of the switch. C. Fuse access door s hall be mechanically interlocked with the operating handle and shall have provisions for padlocking the switch in the OPEN position. D. The switch shall use a stored energy deadfront operating mechanism compressed and released by the operating handle, to provide quick positive switching action, independent of the operating handle. E. Switches shall be manually operated. Quick-Make/Quick-Break Fusible Switches A. Fusible switches 30A through 1200A frames shall be furnished with 300V Class T-type fuse clips unless otherwise scheduled. B. Switches shall incorporate safety cover interlocks to prevent opening the cover with the switch in the ON position. C. Provide defeater for authorized personnel. 5 V1-T5-146 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com D. Handles shall have provisions for padlocking and shall clearly indicate the ON or OFF position. E. Front cover doors shall be padlockable in the CLOSED position. F. Main protective devices shall be quick-make/ quick-break fusible switches as manufactured by Eaton. Tenant Utility Metering A. For EUSERC serviced areas, meter centers shall incorporate metering sections with tenant feeder circuits using ring-type meter sockets rated [125] [200] amperes to meet local utility and/or customer requirements. B. The self-contained meter sockets shall include a test bypass/disconnect block per EUSERC requirements, – OR– A. For non-EUSERC serviced areas, meter centers shall incorporate metering sections with tenant feeder circuits using [ring-] [ringless-] type meter sockets rated [125] [200] [320] amperes to meet local utility or customer requirements. Provide meter sockets with individual covers having sealing provisions. B. Meter sockets shall have manual bypass and optional internal barriers. Enclosures A. NEMA 1 Enclosure – OR– A. Outdoor NEMA 3R Surface-Mounted Enclosure Finish A. Boxes and trims shall be bonderized and finished with ANSI 61 light gray enamel. 5.10 Metering Products Group Metering Dimensions 5 Approximate Dimensions in Inches (mm) 5 General Layout 5 Minimum and maximum height of single-phase and three-phase meter sockets above typical ground level. 1MM/3MM 200 A 1MM/3MM 200 A 1MM/3MM 125 A 35MM/37MM 225 A Maximum 35MM/37MM 225 A Maximum 35MM/37MM 225 A Maximum 37MM 400 A 35MM/37MM 5 13.50 (342.9) 13.50 (342.9) 12.25 (311.2) 19.25 (488.8) 18.25 (463.6) 18.25 (463.6) 18.25 (463.6) 18.25 (463.6) 5 5 5 5 5 Wall Hanger Screws C L 5 34.25 (870.0) 5 5 Main Device a 5 b 30.14 (765.6) 13.38 (339.7) 31.88 (809.6) 26.00 (660.4) 68.25 (1733.6) 71.00 (1803.4) 30.00 (762.0) 30.00 (762.0) 72.00 (1828.8) 58.00 (1473.2) 44.00 (1117.6) 44.00 (1117.6) 58.00 (1473.2) 44.00 (1117.6) 31.00 (787.4) 5 5 Typical Height Above Ground or Floor Level 5 5 Mounting Features 5 5 5 5 5 5 Mounting Features 5 A standard mounting rail and factory-installed swing away feet, speed up and simplify installation. 5 5 Notes 1 Not a constant value. Dimension changes depending on main device chosen. See Page V1-T5-110 for specific dimensions. 2 Residential device. 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-147 Power Pedestals Power Pedestals 6.1 Introduction Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Application Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Optional Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.2 Marina Power and Lighting Temporary Power/RV Park Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Application Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Features and Benefits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Standards and Certifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Renewal Parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Surface Units. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pedestal Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Construction Site and RV Parks 6.3 6.5 V1-T6-21 V1-T6-21 V1-T6-22 V1-T6-22 V1-T6-23 V1-T6-24 RV Park Hook-Ups Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Powerhouse Power Pedestal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Powerhouse—Stainless Steel (SS) Power Pedestal . . . . . . . . . . . . . . Newport Camp Mate Power Pedestal . . . . . . . . . . . . . . . . . . . . . . . . . Park Light Power Pedestal. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Firehouse. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital Electronic Kilowatthour Meters . . . . . . . . . . . . . . . . . . . . . . . . Distribution Equipment—Ground Fault Monitor . . . . . . . . . . . . . . . . . Distribution Equipment—Substations . . . . . . . . . . . . . . . . . . . . . . . . . Distribution Equipment—Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Distribution Equipment—Transformers . . . . . . . . . . . . . . . . . . . . . . . . Mobile Home Panels V1-T6-3 V1-T6-3 V1-T6-4 V1-T6-4 V1-T6-5 V1-T6-6 V1-T6-7 V1-T6-7 V1-T6-8 V1-T6-10 V1-T6-10 V1-T6-10 V1-T6-13 V1-T6-16 V1-T6-16 V1-T6-16 V1-T6-18 Mobile Home Panels Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Catalog Number Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.4 V1-T6-2 V1-T6-2 V1-T6-2 6 6 6 6 6 6 6 6 6 6 6 6 6 6 V1-T6-51 V1-T6-54 V1-T6-58 V1-T6-62 V1-T6-65 V1-T6-69 V1-T6-73 V1-T6-79 V1-T6-80 V1-T6-81 V1-T6-82 V1-T6-83 V1-T6-86 V1-T6-89 V1-T6-90 6 Don’t Give Up! If you don’t find the product you want in this catalog, try the Flex Center at 1-800-330-6479. Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 6 V1-T6-28 V1-T6-30 V1-T6-33 V1-T6-36 V1-T6-39 V1-T6-42 V1-T6-44 V1-T6-45 V1-T6-46 V1-T6-49 V1-T6-50 Marina Power and Lighting Equipment Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lighthouse. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hatteras Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Firehouse. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mariner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital Electronic Kilowatthour Meters . . . . . . . . . . . . . . . . . . . . . . . . Distribution Equipment—Ground Fault Monitor . . . . . . . . . . . . . . . . . Distribution Equipment—Mega Yacht Powerpoint . . . . . . . . . . . . . . . Distribution Equipment—Substations . . . . . . . . . . . . . . . . . . . . . . . . . Distribution Equipment—Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Distribution Equipment—Transformers . . . . . . . . . . . . . . . . . . . . . . . . 6 V1-T6-1 6 6 6 6 6 6 6 6 6 6 6 6 6 6.1 6 Power Pedestals Introduction Contents Power Pedestals Description 6 Introduction 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Product Description Application Description A power pedestal is a device designed for outdoor service to meet temporary power requirements at construction sites, marinas, recreational vehicle (RV parks, marinas and mobile home parks). Power pedestals provide a safe and reliable means for users to access electricity at such locations. Construction Site and RV Parks Power outlet panels on construction sites and in RV parks provide a safe and reliable means for users to access electricity. A wide range of products are available with multiple features and enclosure material options. 6 Optional Features Mobile Home Panels Eaton’s versatile mobile home panels have a user-friendly design that allows for a faster, cleaner installation. Mobile home panels are designed for service entrance distribution, and include a meter and distribution section with breaker and receptacle configuration options. ● ● ● ● ● ● ● ● 6 6 ● 6 6 Mobile Home Panels 6 Marina Power and Lighting 6 Construction Site and RV Parks 6 6 Park lighting and marina pedestals offer robust enclosure options with premium features to enhance user convenience at marinas and campgrounds. 6 6 6 6 6 Marina Power and Lighting V1-T6-2 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Product can ship from the factory completely assembled and prewired External light TV and telephone jacks Ground fault monitors Digital electronic kilowatthour meters Water faucet Available GFI (ground fault interrupter) protection Weatherproof engineered resin enclosure (will never rust or deteriorate) Stainless steel to meet and exceed all applicable codes, and withstand harsh inland and coastal environments Power Pedestals Temporary Power/RV Park 6.2 Contents Power Outlet Panels Description Product Overview . . . . . . . . . . . . . . . . . . . . . . . . . Application Description . . . . . . . . . . . . . . . . . . Features and Benefits . . . . . . . . . . . . . . . . . . . Standards and Certifications . . . . . . . . . . . . . . Catalog Number Selection . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Renewal Parts . . . . . . . . . . . . . . . . . . . . . . . . . Surface Units. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pedestal Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page V1-T6-3 V1-T6-4 V1-T6-4 V1-T6-5 V1-T6-6 V1-T6-7 V1-T6-7 V1-T6-8 V1-T6-10 V1-T6-16 6 6 6 6 6 6 6 6 6 6 6 Product Overview A power outlet panel (or POP) is a device designed for outdoor service to meet temporary power requirements at construction sites and RV parks. POPs provide a safe and reliable means for users to access electricity at such locations. 6 Product Description Power outlet panels shall be designed for outdoor service to meet temporary power outlet requirements at construction sites and provide high quality, economical power to individual sites at RV parks. POPs shall be provided with means to bond the neutral for temporary service entrance applications. RV panels shall have a factoryinstalled insulated neutral bar. Receptacles and Circuit Protection Circuit protection shall be Eaton’s UL listed full-size Type BR or half-size Type BD circuit breakers. The receptacles shall be NEMA commercial/industrial grade devices. Ground fault protection (GFCB) shall be provided at the 20A duplex NEMA 5-20R receptacle or 20A single-pole circuit breaker when required. Ground fault protection shall be provided at the circuit breaker for receptacles above 20A when required. Construction The power outlet panel pedestal shall be of deadfront design and constructed of heavy gauge, 100 percent galvanized steel. Baked-on polyester powder coating shall be used for excellent mechanical strength, plus resistance to chalking caused by the sun’s ultraviolet rays. The power outlet panel surface and pedestal units shall have NEMA Type 3R rainproof enclosures. 6 6 6 6 6 6 6 Ease of Installation Panels shall ship from the factory completely assembled, prewired with 100 percent copper wire, and tested in accordance with UL Standard 231. The door shall swing up and open for user convenience and ease of access to breakers and receptacles. When required, a means for securing the door in the open position shall be provided. Panels shall be bottom fed through knockouts in endwall or top fed using a bolt-on raintight hub. Knockouts shall range from 1/2-inch (12.7 mm) to 1-1/2 inches (38.1 mm). Grounding provisions (#4–14 Cu/Al) shall be provided on all panels. Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 6 6 6 6 6 6 6 6 6 6 6 V1-T6-3 6.2 6 6 6 6 6 6 6 6 6 Power Pedestals Temporary Power/RV Park Application Description POPs are also sometimes called temporary power panels, temporary site service equipment or RV panels. Construction Site Application When POPs are used at a construction site, they are installed on a temporary basis until permanent electrical power is available at the building. The most common reason for needing a POP at a construction site is to provide a power source for the contractor’s tools. Features and Benefits RV Park Applications When POPs are used at an RV park, they are installed for more permanent use and serve the purpose of providing power to the recreational vehicles. Many RV parks now supply customers with amenities such as lighted POPs with TV and telephone jacks. 6 RV Park Application Construction Site Application 6 6 6 6 6 6 6 6 6 ● ● 6 6 ● ● 6 6 ● Service Applications Suitable for use as temporary Service Entrance Equipment, temporary power service equipment and recreational vehicle site supply. Designed for outdoor service to meet power outlet requirements Receptacles conform to NEMA and/or ANSI configurations as specified by the National Electrical Code® (NEC) Includes a factory-installed insulated neutral bar with provisions for bonding when used for temporary service entrance applications 125A rated meter socket Temporary power and RV park POPs are CSA listed. Compact POP and single receptacle devices are not CSA listed Designed for Easy Installation and Protection ● Panels come from the factory completely assembled, prewired with 100 percent copper wire and tested...ready for easy installation ● Door swings up and open for user convenience and ease of access to breakers and receptacles ● Panels can be bottom fed through knockouts in the endwall or top fed using a bolt-on raintight hub ● Two-piece deadfront cover allows field wiring without interfering with factory wiring ● Lower deadfront cover permits easy field wiring to circuit protective devices ● Available GFI (ground fault interrupter) single- and two-pole protection through 50A 6 6 6 6 6 6 6 V1-T6-4 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Power Pedestals Temporary Power/RV Park Two Styles to Meet Your Power Outlet Needs ● Surface mount: User mounts unit to a post ● Pedestal mount: User mounts with an underground pedestal extension or pad-mounting bracket. (Underground pedestal extension and pad-mounting bracket are sold separately. See accessories Page V1-T6-7 for part numbers and options) 6.2 Surface Units 6 NEMA 3R construction for rainproof installation 6 100 percent galvanized steel with baked-on polyester powder coating Utility grade metering available for construction site or RV park applications 6 Three-point mounting Door swings up when opening and allows cords to remain connected when closed. One-piece case back for metered and unmetered panels Lighted option for site location and nighttime panel operations 6 6 6 Removable upper deadfront cover for easy incoming wire connections to breaker terminals 6 6 GFI circuit breakers available through 50A Unique steel barrier prevents unauthorized operation of breakers when door is closed and padlocked • Metered units available with meter on top or on bottom Lower deadfront cover can be removed for easy routing of incoming wires or receptacle changeouts 6 Padlock provisions to prevent unauthorized entry 6 6 6 • Units are factory wired and assembled 6 Compact Design Available in Certain Configurations for Added Convenience Pedestal Units 6 Standards and Certifications UL Standard 231 UL File Number E163588 Receptacles conform to NEMA and/or ANSI configurations as specified by the NEC. ● Standard Compliance All power outlet panels for temporary construction site power and RV (recreational vehicle) application shall be UL listed for the U.S. per UL Standard 231, File E163588. Receptacles shall conform to NEMA and/or ANSI configurations as specified by the National Electrical Code (NEC). 6 NEMA 3R construction for rainproof installation ● 100 percent galvanized steel with baked-on polyester powder coating 6 Utility grade metering available for construction site or RV park applications 6 6 6 Door swings up when opening and allows cords to remain connected when closed GFI circuit breakers (single- and two-pole) available through 50A One-piece case back for metered and unmetered panels Loop-feed lug assembly with 350 kcmil lugs included as standard 6 6 Removable upper deadfront cover for easy incoming wire connections to breaker terminals 6 Unique steel barrier prevents unauthorized operation of breakers when door is closed and padlocked 6 6 Lower deadfront cover can be removed for easy routing of incoming wires or receptacle changeouts 6 6 Padlock provisions to prevent unauthorized entry 6 Pedestal extension available for underground services 6 Pad-mounted bracket option also available 6 • Units are factory wired and assembled Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 6 V1-T6-5 6.2 6 Power Pedestals Temporary Power/RV Park Catalog Number Selection CH M 1 N 7 N 4 N P X L TZ U 6 6 Feed Eaton’s Cutler-Hammer® Series 6 6 U= Bottom fed Blank =Top fed Metering Type U = Unmetered M = Metered-ring R = Metered-ringless 6 6 Pedestal Extension Receptacle Type Center Position 1 See “Receptacle Type Left Position” for code selection Receptacle Type Left Position 1 6 1 = NEMA 14-50R 3 = NEMA 14-30R 4 = NEMA TT-30R 5 = NEMA 6-20R2 6 = NEMA 5-20R2 7 = NEMA 5-20R2GFI 8 = NEMA 5-20R2GFI 2 9 = NEMA 5-20R2GFI 3 6 6 6 A= B= C= D= E= F= H= J= Blank = NEMA L14-50R NEMA L6-50R NEMA L5-50R NEMA L14-30R NEMA L6-30R NEMA L5-30R NEMA L6-20R NEMA L5-20R No receptacle TZ= Factory installed pedestal extension with lay-in ground lug Receptacle Type Right Position 1 See “Receptacle Type Left Position” for code selection Lighting L = Lighted Circuit Breaker Type Position 2 N = Non-ground fault G = Ground fault Circuit Breaker Type Position 3 Interior N = Non-ground fault G = Ground fault X= Six circuit Blank = Standard Four circuit Circuit Breaker Type Position 1 6 Mounting N = Non-ground fault G = Ground fault S = Surface P = Pedestal B = Back-to-back pedestal 6 6 6 Notes 1 For receptacle configurations, see table below. 2 Weather-resistant. 3 Weather-resistant/tamper resistant. 6 Receptacle Configuration 6 1 6 6 3 4 30A, 125V, two-pole, three-wire, NEMA TT-30R 8 WR 20A, 125V, two-pole, three-wire, weather-resistant (WR), NEMA 5-20R2GFI 20A, 125V, two-pole, three-wire, NEMA 5-20R2 9 WR 20A, 125V, two-pole, three-wire, weather-resistant/ tamper-resistant (WR TR), NEMA 5-20R2GFI TR Single-pole, 20A breaker 7 20A, 125V, two-pole, three-wire, NEMA 5-20R2GFI Single-pole, 20A breaker Twist-Lock and Custom Receptacle/Breaker Combinations A 50A, 125/250V, three-pole, three-wire, NEMA L14-50R B 50A, 250V, two-pole, three-wire, NEMA L6-50R D 30A, 125/250V, three-pole, four-wire, NEMA L14-30R E 30A, 250V, two-pole, three-wire, NEMA L6-30R Two-pole, 50A breaker 6 6 6 Single-pole, 30A breaker 6 6 30A, 125/250V, three-pole, four-wire, NEMA 14-30R 20A, 250V, two-pole, three-wire, NEMA 6-20R2 Two-pole, 20A breaker Two-pole, 30A breaker 6 6 5 Two-pole, 50A breaker 6 6 50A, 125/250V, three-pole, four-wire, NEMA 14-50R Two-pole, 30A breaker Two-pole, 50A breaker C 6 50A, 125V, two-pole, three-wire, NEMA L5-50R Single-pole, 50A breaker H Two-pole, 20A breaker J Two-pole, 30A breaker F 30A, 125V, two-pole, three-wire, NEMA L5-30R Single-pole, 30A breaker 6 6 V1-T6-6 20A, 250V, two-pole, three-wire, NEMA L6-20R Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 20A, 125V, two-pole, three-wire, NEMA L5-20R Single-pole, 20A breaker Power Pedestals Temporary Power/RV Park 6.2 Product Selection When quoting or selecting a power outlet panel, the following questions should be answered: ● ● ● ● ● Unmetered, ring or ringless style Number and types of receptacles (seven standard and eight twist-lock options) Standard or ground fault breakers Surface, pedestal or back-to-back mounting Are any factory or field options required? Power Outlet Panel Receptacle Configuration Rules ● Four Receptacles/Unit All receptacles must be NEMA 5-20R2 or NEMA 5-20R2GFI, surface mount only. Three Receptacles/Unit ● ● One or more of the receptacles must be NEMA 6-20R2, NEMA 5-20R2 or NEMA 5-20R2GFI NEMA 6-20R2, NEMA 5-20R2, or NEMA 5-20R2GFI must go in the second position 6 If two receptacles consist of types NEMA 14-50R, NEMA 10-50R, NEMA 14-30R or NEMA 6-20R2 a six-circuit interior must be added ● Example: CHUIN5N2NSX 6 6 6 6 Note: Configuration 1 and 2 were chosen so a six-circuit interior needs to be added (suffix X) to the end of the catalog number. Also, configuration 5 is in the second position. 6 6 6 Two, One and Zero Receptacles/Unit Any configuration. 6 6 Accessories 6 Accessories Underground Pedestal Extension Description Catalog Number 6 Underground pedestal extension CHPEDEXT Stainless steel underground pedestal extension CHPEDEXTSS 6 6 6 6 6 Pad-Mount Bracket Pad-mount bracket 6 CHPADEXT 6 Cable TV/Telephone Bracket Cable TV and telephone bracket 6 CHTELTV 6 6 DS Hub Fluorescent Light Kit Rainproof conduit hub 0.75 inch (19.1 mm) DS075H1 Rainproof conduit hub 1.00 inch (25.4 mm) DS100H1 Rainproof conduit hub 1.25 inch (31.8 mm) DS125H1 Rainproof conduit hub 1.50 inch (38.1 mm) DS150H1 6 6 6 6 Fluorescent Light Kit Description Catalog Number Converts power outlet panel to lighted unit, must also order CHOUTCVRL CHFLGTKIT 6 6 6 6 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-7 6.2 6 Power Pedestals Temporary Power/RV Park Renewal Parts Renewal Parts 6 Description Catalog Number Circuit Breaker (BR/GFCB) See this volume, Tab 1, section 1.2 — Meter Socket Ring style replacement meter socket CHPOPMSRING Ringless style replacement meter socket CHPOPMSRL 5th jaw kit ARP00035CHJ Horn bypass (one lug cap per kit; four kits required per device) ARP00777CH Bonding Strap and Mounting Hardware Bonding strap and mounting hardware CHBONDST Inner Lens Inner lens for lighted power outlet panels CHINLENS Loop Feed Lug Assembly Loop feed lug assembly for single pedestal CHLOOPFDP Loop feed lug assembly for back-to-back pedestal CHLOOPFDB Lower Deadfront Cover Blank lower deadfront cover CHLDFCVR 6 Lower deadfront cover with duplex receptacle opening CHLDFCVR1 Lower deadfront cover with duplex, duplex receptacle opening CHLDFCVR2 6 Lower deadfront cover with duplex, duplex, duplex receptacle opening CHLDFCVR3 Lower deadfront cover with rectangle receptacle opening CHLDFCVR4 6 Lower deadfront cover with rectangle, rectangle receptacle opening CHLDFCVR5 6 Lower deadfront cover with rectangle, rectangle, rectangle receptacle opening CHLDFCVR6 Lower deadfront cover with duplex, rectangle receptacle opening CHLDFCVR7 6 Lower deadfront cover with duplex, rectangle, duplex receptacle opening CHLDFCVR8 Lower deadfront cover with rectangle, rectangle, duplex receptacle opening CHLDFCVR9 6 Lower deadfront cover with round receptacle opening CHLDFCVR10 Lower deadfront cover with round, round receptacle opening CHLDFCVR11 Lower deadfront cover with round, duplex receptacle opening CHLDFCVR12 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 V1-T6-8 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Power Pedestals Temporary Power/RV Park 6.2 Renewal Parts, continued Upper Deadfront Cover Description Catalog Number Lower deadfront cover with round, duplex, duplex receptacle opening CHLDFCVR13 Lower deadfront cover with round, duplex, round receptacle opening CHLDFCVR14 Lower deadfront cover with round, rectangle receptacle opening CHLDFCVR15 Lower deadfront cover with round, rectangle, rectangle receptacle opening CHLDFCVR16 Lower deadfront cover with round, rectangle, round receptacle opening CHLDFCVR17 Lower deadfront cover with round, rectangle, duplex receptacle opening CHLDFCVR18 Upper deadfront cover with six breaker twistouts CHUDFCVR Upper deadfront cover with provisions for lighted option CHUDFCVRL 6 6 6 6 6 6 6 6 Outer Door Outer door 6 CHOUTCVR 6 6 6 6 Outer Door with Lens Outer door with lens CHOUTCVRL 6 6 6 6 Neutral Assemblies 6 Six-hole neutral assembly with 2/0 lug CHNEUT Seven-hole neutral assembly with 2/0 lug CHNEUT1 Five-hole ground bar kit GBK5 10-hole ground bar kit GBK10 6 6 6 Replacement Meter Cover Replacement meter cover—ring type CHPOPRMC Replacement meter cover—ringless CHPOPRLMC Replacement meter cover—ringless CHPOPRLMCN Replacement meter cover—ringless CHPOPRLMCN2 6 6 6 6 6 6 6 6 6 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-9 6.2 6 Power Pedestals Temporary Power/RV Park Contents Power Outlet Panels Description 6 Page Product Overview. . . . . . . . . . . . . . . . . . . . . . . . . . Surface Units Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pedestal Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 6 V1-T6-3 V1-T6-13 V1-T6-16 6 6 6 6 6 6 6 Surface Units 6 Product Overview 6 6 6 6 6 A power outlet panel (or POP) is a device designed for outdoor service to meet temporary power requirements at construction sites and recreation vehicle (RV) parks. POPs provide a safe and reliable means for users to access electricity at such locations. 6 Product Selection Power Outlet Panel Receptacle Configuration Rules See Page V1-T6-8 for Three Receptacles/Unit complete list. For 100A Main ● One or more of the Breaker, contact the Flex receptacles must be Center (1-800-330-6479). NEMA 6-20R2, NEMA 5-20R2 or Four Receptacles/Unit NEMA 5-20R2GFI All receptacles must be ● NEMA 6-20R2, NEMA 5-20R2 and/or NEMA 5-20R2, or NEMA 5-20R2GFI, surface NEMA 5-20R2GFI must mount only. go in the second position ● 6 6 6 6 6 If two receptacles consist of types NEMA 14-50R, NEMA 10-50R, NEMA 14-30R or NEMA 6-20R2 a six-circuit interior must be added ● Example: CHUIN5N2NSX Note: Configuration 1 and 2 were chosen so a six-circuit interior needs to be added (suffix X) to the end of the catalog number. Also, configuration 5 is in the second position. 6 6 6 6 6 6 6 V1-T6-10 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Two, One and Zero Receptacles/Unit Any configuration. Options ● ● ● ● Six-circuit interior Factory-mounted pedestal extension Lighted Bottom fed 6.2 Power Pedestals Temporary Power/RV Park Surface Type Receptacle Description Ampere Series Single Receptacle CHU4S Unmetered (Compact Version) Position Left Center Right 1st 2nd 3rd Catalog Number 14-50R — No breaker No breaker No breaker CHU1S 6 6 Unmetered Single Receptacle 50 Unmetered Type CHU1N7N4NS 6 Breaker Description — 6 30 — 14-30 R — No breaker No breaker No breaker CHU3S 30 — TT-30R — No breaker No breaker No breaker CHU4S 20 — 6-20R2 — No breaker No breaker No breaker CHU5S 20 — 5-20R2 — No breaker No breaker No breaker CHU6S 20 — 5-20R2GFI — No breaker No breaker No breaker CHU7S 20/20/20 5-20R2 5-20R2 6-20R2 GFI GFI GFI CHU6G6G5GS 20/20/20 5-20R2GFI 5-20R2GFI 6-20R2 Non-GFI Non-GFI Non-GFI CHU7N7N5NS 20/20/20 5-20R2GFI 5-20R2GFI 6-20R2 Non-GFI Non-GFI GFI CHU7N7N5GS 50/20/30 14-50R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHU1N7N4NS 50/20/30 14-50R 5-20R2GFI 6-20R GFI Non-GFI Non-GFI CHU1G7N7NS 50/20 14-50R 5-20RGFI — GFI Non-GFI — CHU1G7NS 50/20 14-50R 5-20RGFI — Non-GFI Non-GFI — CHU1N7NS 50/20/50 14-50R 5-20R2GFI 14-50R Non-GFI Non-GFI Non-GFI CHU1N7N1NSX 1 30/30/20 TT-30R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHU4N7N4NS 20/20/20 5-20R2 5-20R2 6-20R2 GFI GFI GFI CHU6G6G5GS6OM 2 6 6 6 Unmetered 6 6 6 Unmetered (Compact Version) 50 14-50R — — Non-GFI — — CHU1NS 20 5-20R2 — — Non-GFI — — CHU2NS 30 TT-30R — — GFI — — CHU4GS 30/30 TT-30R TT-30R — Non-GFI Non-GFI — CHU4N4NS 30/20 TT-30R 5-20R2 — Non-GFI Non-GFI — CHU4N6NS 30/20 TT-30R 5-20R2GFI — Non-GFI Non-GFI — CHU4N7NS 30 TT-30R — — Non-GFI — — CHU4NS 20 6-20R2 — — GFI — — CHU5GS 20/20 5-20R2 5-20R2 — GFI GFI — CHU6G6GS 20 5-20R2 — — GFI — — CHU6GS 20/20 5-20R2 5-20R2 — Non-GFI Non-GFI — CHU6N6NS 20 5-20R2 — — Non-GFI — — CHU6NS 20/20 5-20R2GFI 5-20R2GFI — Non-GFI Non-GFI — CHU7N7NS 20 5-20R2GFI — — Non-GFI — — CHU7NS 6 6 6 6 6 6 6 6 6 6 6 6 Notes 1 The “X” suffix indicates that a six circuit interior is provided, instead of the standard four circuit interior. 2 Includes 60A two-pole main breaker for service disconnect ratings. 6 Contact your local Eaton sales office for configurations not listed. 6 6 6 6 6 6 6 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-11 6.2 Temporary Power/RV Park Surface Type, continued 6 Receptacle Description 6 6 Power Pedestals Ampere Series Metered Ring CHM1G7NS 6 Breaker Description Position Left Center Right 1st 2nd 3rd Catalog Number Metered—Ring 50/20/20 14-50R 5-20R2GFI 5-20R2GFI GFI Non-GFI Non-GFI CHM1G7N7NS 20/20 5-20R2GFI 5-20R2GFI — Non-GFI Non-GFI — CHM7N7NS 6 20/20/20 5-20R2GFI 5-20R2GFI 6-20R2 Non-GFI Non-GFI GFI CHM7N7N5GS 20/20/20 5-20R2GFI 5-20R2GFI 6-20R2 Non-GFI Non-GFI Non-GFI CHM7N7N5NS 6 50/30/20 14-50R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHM1N7N4NS 50/20 14-50R 5-20R2GFI — Non-GFI Non-GFI — CHM1N7NS 20/20 6-20R2 5-20R2GFI — Non-GFI Non-GFI Non-GFI CHM5N7NS 5-20R2GFI — GFI Non-GFI — CHR1G7NS 6 6 6 6 Metered Ringless Type CHR4N7NS Metered—Ringless 6 50/20 14-50R 20/20 5-20R2GFI 5-20R2GFI — Non-GFI Non-GFI — CHR7N7NS 6 50/20/20 14-50R 5-20R2GFI 5-20R2GFI GFI Non-GFI Non-GFI CHR1G7N7NS 50/20 14-50R 5-20R2GFI — Non-GFI Non-GFI — CHR1N7NS 6 20/20/20 5-20R2GFI 5-20R2GFI 5-20R2GFI Non-GFI Non-GFI Non-GFI CHR7N7N7NS 6 30/20/20 14-30R 5-20R2GFI 5-20R2GFI Non-GFI Non-GFI Non-GFI CHR3N7N7NS 50/30/20 14-50R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHR1N7N4NS 6 6 6 Metered Ring or Ringless Type Bottom Feed 6 Metered—Ring—Bottom Fed 20/20 5-20R2GFI 5-20R2GFI — Non-GFI Non-GFI — CHM7N7NSU 20/20/20 5-20R2GFI 5-20R2GFI 6-20R2 Non-GFI Non-GFI GFI CHM7N7N5GSU 50/20/20 14-50R 5-20R2GFI 5-20R2GFI GFI Non-GFI Non-GFI CHM1G7N7NSU 6 Metered—Ringless—Bottom Fed 20/20 5-20R2GFI 5-20R2GFI — Non-GFI Non-GFI — CHR7N7NSU 6 50/20 14-50R 5-20R2GFI — GFI Non-GFI — CHR1G7NSU 50/20 10-50R 5-20R2GFI — GFI Non-GFI — CHR2G7NSU 6 20/20/20 5-20R2GFI 5-20R2GFI 6-20R2 Non-GFI Non-GFI GFI CHR7N7N5GSU 6 20/20/20 5-20R2GFI 5-20R2GFI 6-20R2 Non-GFI Non-GFI Non-GFI CHR7N7N5NSU 20/20/20 5-20R2GFI 5-20R2GFI 5-20R2GFI Non-GFI Non-GFI Non-GFI CHR7N7N7NSU 6 30/20/20 14-30R 5-20R2GFI 5-20R2GFI Non-GFI Non-GFI Non-GFI CHR3N7N7NSU 30/20/20 14-30R 5-20R2GFI 5-20R2GFI GFI Non-GFI Non-GFI CHR3G7N7NSU 6 50/20/20 14-50R 5-20R2GFI 5-20R2GFI GFI Non-GFI Non-GFI CHR1G7N7NSU 50/20/30 14-50R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHR1N7N4NSU 6 6 Accessories See Page V1-T6-7. 6 6 6 6 V1-T6-12 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Power Pedestals Temporary Power/RV Park 6.2 Dimensions 6 Approximate Dimensions in Inches (mm) 6 Single Receptacle 0.24 (6.1) 6 6.58 (167.1) 6 2.63 (66.8) 6 6 6 6 6 7.10 (108.3) 6 4.50 (114.3) 6 6 3.18 (80.8) 6 1.30 (33.0) 6 2.50 (63.5) 1.87 (47.5 ) 6 6 6.23 (158.2) 6 6 4.79 (121.7) 4.27 (108.5) 6 6 0.13 (3.3) 6 6 6 6 6 6 6 6 6 6 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-13 6.2 Power Pedestals Temporary Power/RV Park 6 Approximate Dimensions in Inches (mm) 6 Compact Design Option 6 0.30 (7.62) 6.58 (167.1) 6 6.94 (176.3) 4.27 (108.5) 0.13 (3.3) 6 6 6 6 11.66 (296.2) 6 7.26 (184.4) 6 Center Line for Receptacle 6 2.43 (61.7) 6 1.89 (48.0) 6 2.14 (54.4) 4.89 (124.2) 6 6 6 6 6 Unmetered Units 6 Unmetered Surface Type 4.30 (109.2) 9.50 (241.3) 6 0.07 (1.7) 6 6 6 6 6 17.10 (434.3) 14.50 (368.3) Locking Provision 6 6 6 6 6.70 (170.2) 6 V1-T6-14 1.30 (33.0) Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Power Pedestals Temporary Power/RV Park 6.2 Approximate Dimensions in Inches (mm) 6 Metered Units (Ring and Ringless) 6 Metered Surface Type 4.50 (114.3) 4.30 (109.2) 9.50 (241.3) 6 6 0.07 (1.7) 6 6 6 6 6 6 30.00 (762.0) 6 22.50 (571.5) 6 Locking Provision 6 6 6 6.70 (170.1) Sealing Provision 6 6 Bottom Fed Type 6.80 (172.8) 4.31 (109.5) 9.49 (241.1) 6 6 0.06 (1.6) 6 6 6 Locking Provision 6 6 30.10 (764.6) 6 6 17.11 (434.7) 6 12.97 (329.4) 6 6.15 (156.2) Sealing Provision 6 6 4.93 (125.2) Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-15 6.2 6 Power Pedestals Temporary Power/RV Park Contents Power Outlet Panels Description 6 Page Product Overview. . . . . . . . . . . . . . . . . . . . . . . . . . Surface Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pedestal Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 6 V1-T6-3 V1-T6-10 V1-T6-16 V1-T6-18 6 6 6 6 6 6 6 Pedestal Units 6 Product Overview 6 6 6 6 6 A power outlet panel (or POP) is a device designed for outdoor service to meet temporary power requirements at construction sites and recreation vehicle (RV) parks. POPs provide a safe and reliable means for users to access electricity at such locations. 6 Product Selection Power Outlet Panel Receptacle Configuration Rules See Page V1-T6-8 for Three Receptacles/Unit complete list. For 100A Main ● One or more of the Breaker, contact the Flex receptacles must be Center (1-800-330-6479). NEMA 6-20R2, NEMA 5-20R2 or Four Receptacles/Unit NEMA 5-20R2GFI All receptacles must be ● NEMA 6-20R2, NEMA 5-20R2 and/or NEMA 5-20R2, or NEMA 5-20R2GFI, surface NEMA 5-20R2GFI must mount only. go in the second position ● 6 6 6 6 6 If two receptacles consist of types NEMA 14-50R, NEMA 10-50R, NEMA 14-30R or NEMA 6-20R2 a six-circuit interior must be added ● Example: CHUIN5N2NSX Note: Configuration 1 and 2 were chosen so a six-circuit interior needs to be added (suffix X) to the end of the catalog number. Also, configuration 5 is in the second position. 6 6 6 6 6 6 6 V1-T6-16 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Two, One and Zero Receptacles/Unit Any configuration. Options ● ● ● ● Six-circuit interior Factory-mounted pedestal extension Lighted Bottom fed 6.2 Power Pedestals Temporary Power/RV Park Unmetered Type Pedestal Type Receptacle Description Ampere Series 6 Breaker Description Position 6 Left Center Right 1st 2nd 3rd Catalog Number 50/30/20 14-50R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHU1N7N4NP 30/20 TT-30R 5-20R2GFI — Non-GFI Non-GFI — CHU4N7NP 50/30/20 14-50R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHU1N7N4NPTZ 6 Unmetered 6 TT-30R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHU4N7N4NP 30/20 TT-30R 5-20R2GFI — Non-GFI Non-GFI — CHU4N7NPTZ 50/30/20 14-50R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHM1N7N4NP 50/20 14-50R 5-20R2GFI — Non-GFI Non-GFI — CHM1N7NP 50/30/20 14-50R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHM1N7N4NPTZ 30/20 TT-30R 5-20R2GFI — Non-GFI Non-GFI — CHM4N7NPTZ 6 6 6 Metered—Ring CHM1N7N4NPTZ 6 30/30/20 Metered—Ringless 50/30/20 14-50R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHR1N7N4NP 50/20/50 14-50R 5-20R2GFI 14-50R Non-GFI Non-GFI Non-GFI CHR1N7N1NPX 50/20/30 14-50R 5-20R2GFI 14-30R Non-GFI Non-GFI Non-GFI CHR1N7N3NPX 50/20/30 14-50R 5-20R2 14-30R Non-GFI Ground fault Non-GFI CHR1N6G3NPX 6 6 6 6 6 6 6 6 CHU1N7N4NBTZ 6 Back-to-Back Pedestal Type Receptacle Description Ampere Series Breaker Description Position Left Center Right 1st 2nd 3rd Catalog Number 6 6 Unmetered 1 30/30/20 TT-30R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHU4N7N4NB 50/30/20 14-50R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHU1N7N4NBTZ Metered—Ring 1 30/20 TT-30R 5-20R2GFI — Non-GFI Non-GFI — CHM4N7NB 50/30/20 14-50R 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHM1N7N4NB 5-20R2GFI TT-30R Non-GFI Non-GFI Non-GFI CHR1N7N4NBTZ 6 Metered—Ringless 1 50/30/20 14-50R 6 6 6 6 6 Notes 1 The pedestal back-to-back units have receptacles and circuit breakers as shown for each panel and share one common pedestal with loop feed lugs. 6 Contact your local Eaton sales office for configurations not listed. 6 Accessories See Page V1-T6-7. 6 6 6 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-17 6.2 6 Power Pedestals Temporary Power/RV Park Dimensions Approximate Dimensions in Inches (mm) 6 Metered Units 6 100A Pedestal Ringless U.G. Feed Pedestal-Mount 6 6 6 6 .79 (20.1) 6 .904 6 6 100A 1" Secondary Hit Exit Hole B/B Only A N B 6.10 (154.9) Sections Through at Meter Socket .63 (15.9) 6 6 1" 100A 4.108 6 6 100A 4.00 (101.6) 3.077 6 6 Gasket .92 (23.4) ÿ2.500 6 6 1" 100A 4.00 (101.6) 100A 4.46 (113.3) 100A 6 .12 (3.1) 1" A0 01 10.78 (273.7) 1" 10.24 (260.0) A0 01 6 1" 7.44 (188.9) 18.02 (457.7) Sections Through At Upper Barrier ÿ2.50 (63.5) ÿ1.50 Sections Through At Lower Barrier 6 6 6 33.00 (838.2) 33.00 (838.2) 6 6 6 6 6 6 STRIP CURRENT INTERRUPTING RATING MAX. RMS SYM. AMPERES 10,000 AT 120/240 VOLTS AC .438 6 V1-T6-18 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Power Pedestals Temporary Power/RV Park 6.2 Approximate Dimensions in Inches (mm) 6 Metered Units (Ring and Ringless) 6 Metered Back-to-Back Pedestal Type 6 6 6 6 6 6 6 6 6 6 6 6 6 0.75 (19.1) 6 Bottom Fed Type 6.80 (172.8) 4.31 (109.5) 9.49 (241.1) 6 6 0.06 (1.6) 6 6 6 6 Locking Provision 6 6 30.10 (764.6) 6 6 17.11 (434.7) 6 12.97 (329.4) 6 6.15 (156.2) 6 Sealing Provision 4.93 (125.2) Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 6 V1-T6-19 6.2 6 6 Power Pedestals Temporary Power/RV Park Approximate Dimensions in Inches (mm) Unmetered Back-to-Back Pedestal Type 13.60 (345.4) 8.60 (218.4) 6 6 6 Locking Provision 6 6 6 6 6 19.20 (487.7) 6 6 6 6 6 0.75 (19.1) Unmetered Pedestal Type 6 3.30 (83.8) Metered Pedestal Type 9.50 (241.3) 6.80 5.00 (172.7) (127.0) 9.50 (241.3) 6 6 6 6 6 39.10 (993.1) 6 39.90 (1013.5) 52.00 (1320.8) Locking Provision 6 44.50 (1130.3) 6 6 6 25.80 (655.3) 22.00 (558.8) 16.90 (429.3) 6 9.20 (233.7) 9.40 (238.8) 6 6 Sealing Provision 6 V1-T6-20 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 4.30 (109.2) Power Pedestals Mobile Home Panels 6.3 Contents Power Outlet Panels Description Page Mobile Home Panels Catalog Number Selection . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-22 V1-T6-22 V1-T6-23 V1-T6-24 6 6 6 6 6 6 6 6 6 6 Product Overview Eaton’s versatile Mobile Home Panels have a userfriendly design that allows for a faster, cleaner installation. 100 and 200A panels come complete with the main breaker and a 4/8 or 8/16 interior, respectively. The 200A units are designed with ample width to ensure plenty of room for wire bending and an easier installation. 6 Features Receptacle Deadfront Kits Fastenerless Socket Design Optional receptacle deadfront kits enable the field installation of contractor supplied receptacles and breakers that can supply power for a variety of applications including: ● ● ● ● ● ● Visiting RVs Temporary power Lawn equipment Air compressors Anything else that requires cord-connected power Eliminates overheating caused by loose socket connections Pedestal Unit ● ● Convenient and sturdy ground mounting Loop feed feature allows several units to be connected in series 6 Easier, Better and Faster Installation ● ● More wire bending and viewing room Additional circuits mean more flexibility 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-21 6.3 6 6 Power Pedestals Mobile Home Panels Catalog Number Selection Mobile Home Panels MH M 100 P 1 N 4 N 6 6 Type MH = Mobile Home Panel 6 Circuit Breaker Type Position 2 Metering Type M = Metered-ring R = Metered-ringless 6 6 Amperes 100 150 200 6 6 6 6 6 6 6 Circuit Breaker Type Position 1 Mounting P = Pedestal B = Back-to-back N = Non-ground fault G = Ground fault Optional Receptacle Type Position 1 1= NEMA 14-50R 3= NEMA 14-30R 4= NEMA TT-30R 5= NEMA 6-20R2 6= NEMA 5-20R2 7= NEMA 5-20R2GFI 8= NEMA 5-20R2GFI (WR) 9= NEMA 5-20R2GFI (WR/TR) Blank = No receptacle N = Non-ground fault G = Ground fault Optional Receptacle Type Position 2 1= NEMA 14-50R 3= NEMA 14-30R 4= NEMA TT-30R 5= NEMA 6-20R2 6= NEMA 5-20R2 7= NEMA 5-20R2GFI 8= NEMA 5-20R2GFI (WR) 9= NEMA 5-20R2GFI (WR/TR) Blank = No receptacle Product Selection Mobile Home Panel Mobile Home Panels 1 Amperes Security Interior Main Branch Breakers Receptacles Catalog Number 100 Ring 4/8 BR2100 BR 100 Ring 4/8 BR2100 BR Pedestal None MHM100P Back-to-back None 6 100 Ringless 4/8 BR2100 BR MHM100B Pedestal None 100 Ringless 4/8 BR2100 MHR100P BR Back-to-back None 6 150 Ring 8/16 MHR100B CSR2150 BR Pedestal None 150 Ring MHM150P 8/16 CSR2150 BR Back-to-back None 6 150 MHM150B Ringless 8/16 CSR2150 BR Pedestal None MHR150P 150 Ringless 8/16 CSR2150 BR Back-to-back None MHR150B 6 200 Ring 8/16 CSR2200 BR Pedestal None MHM200P 6 200 Ring 8/16 CSR2200 BR Back-to-back None MHM200B 200 Ringless 8/16 CSR2200 BR Pedestal None MHR200P 6 200 Ringless 8/16 CSR2200 BR Back-to-back None MHR200B 200 Ringless 8/16 CSR2200 BR Pedestal Qty 1 14-50R Qty 2 TT-30R MHM200P1N4N4N 6 6 6 Mounting Note 1 Pedestal Extension included with Mobile Home Panels. 6 6 6 6 6 6 6 V1-T6-22 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Power Pedestals Mobile Home Panels 6.3 Mobile Home Panel Deadfronts for 200A Units 1 6 Available Receptacle Deadfront Kits—Receptacles and Breakers Not Included 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Accessories 6 Mobile Home Panels Hubs not used on mobile home panels. Description Amperes Catalog Number Direct feed kit — MHDFK Pedestal extension 200 MHPEDEXT Stainless steel pedestal extension 200 MHPEDEXTSS Padmount adapter 200 MHPADEXT Pedestal extension 100 CHPEDEXT100 Stainless steel pedestal extension 100 CHPEDESTSS100 Padmount adapter 100 CHPADEXT100 6 6 6 6 6 6 Note 1 For 100A units, the accessory Catalog Number would be MHD1___. For example, to order a deadfront to accept one 30A receptacle (round) in a 100 ampere device, the Catalog Number would be MHD1X. 6 6 6 6 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-23 6.3 6 6 6 Power Pedestals Mobile Home Panels Dimensions Approximate Dimensions in Inches (mm) Mobile Home Panel—Ringless—Pedestal Mounting Ringless Socket Rated 200 A Continuous 6 5.98 (152.0) 6 14.45 (367.0) 5.31 (134.8) 6 6 6 6 1-1/4, 1-1/2, 2, 2-1/2 (31.8, 38.1, 50.8, 63.5) Knockout 1, 1-1/4, 1-1/2, 2 (25.4, 31.8, 38.1, 50.8) Knockout ON 5/16 (7.9) Diameter KO Opposite Side Only 6 OFF Sealing Provision Door Not Shown 57.81 (1468.3) 6 200A Main Breaker 50.08 (1272.1) 6 Optional Direct Feed Kit Shown Installed (Cover Not Shown) 6 28.01 (711.5) 6 6 27.87 (708.0) 24.65 (626.1) 28.70 (729.0) 1/2, 3/4,1 (12.7, 19.1, 25.4) KO (2 Required) 23.69 (601.8) 2.00 (50.8) 6 43.20 (1097.4) 1/2, 3/4, 1, 1-1/4, 1-1/2 (12.7, 19.1, 25.4, 31.8, 38.1) KO Sealing Provision 1.21 (30.7) Bottom Endwall Direct Feed Kit Grade Level 6 6 6 6 6 6 6 6 6 6 6 6 6 6 V1-T6-24 1, 1-1/4, 1-1/2, 2 (25.4, 31.8, 38.1, 50.8) KO Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 6.3 Power Pedestals Mobile Home Panels 6 Approximate Dimensions in Inches (mm) 6 Mobile Home Panel—Ringless—Back-to-Back Mounting 6 Front View Back View 12.09 (307.2) 6 Ringless Socket Rated 200 A Continuous 10.75 (272.9) 6 14.45 (367.0) 6 Sealing Provision 57.81 (1468.3) Door Not Shown 5/16 (7.9) Diameter KO Opposite 200A Side Only Main Breaker 1-1/4, 1-1/2, 2, 2-1/2 (31.8, 38.1, 50.8, 63.5) Knockout 1,1-1/4, 1-1/2, 2 (25.4, 31.8, 38.1, 50.8) Knockout 6 3/4, 1 (19.1, 25.4) KO 5/16 (7.9) Diameter KO (3) Required 6 1/2, 3/4 (12.7, 19.1) KO (2) Required 6 1-1/2, 2, 2-1/2, 3 (38.1, 50.8, 63.5, 76.2) KO Bottom Endwall Back Unit 50.08 (1272.1) 22.01 (711.5) 6 1/2 (12.7) KO (3) Required ON 5/16 (7.9) Diameter KO Opposite Side Only OFF ON Door Not Shown OFF 1-1/4, 1-1/2, 2, 2-1/2 (31.8, 38.1, 50.8, 63.5) KO (2) Required Optional Direct Feed Kit Shown Installed (Cover Not Shown) 1/2, 3/4, 1 (12.7, 19.1, 25.4) KO (2) Required 28.70 (729.0) 18.69 (474.6) 2.00 (50.8) 23.69 (601.8) 1.21 (30.7) 6 43.20 (1097.4) 27.87 (708.0) 25.00 (635.0) 6 Sealing Provision 6 1, 1-1/4, 1-1/2, 2 (25.4, 31.8, 38.1, 50.8) KO 6 1/2, 3/4, 1, 1-1/4, 1-1/2 (12.7, 19.1, 25.4, 31.8, 38.1) KO 6 6 Bottom Endwall Direct Feed Kit 6 Grade Level 6 6 6 6 6 6 6 6 6 6 6 6 6 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-25 6.3 Power Pedestals Mobile Home Panels 6 Approximate Dimensions in Inches (mm) 6 Mobile Home Panel—Ring—Pedestal Mounting 5.56 (141.3) 6 5.31 (134.8) 14.45 (367.0) Ring Type Socket Rated 200 A Continuous 6 5/16 (7.9) Diameter KO Opposite Side Only 6 6 6 1-1/4, 1-1/2, 2, 2-1/2 (31.8, 38.1, 50.8, 63.5) Knockout 1, 1-1/4, 1-1/2, 2 (25.4, 31.8, 38.1, 50.8) KO Door Not Shown 200A Main Breaker 57.81 (1468.3) 6 50.08 (1272.1) 6 6 ON 6 OFF 6 43.20 (1097.4) Optional Direct Feed Kit Shown Installed (Cover Not Shown) 24.64 (626.0) 6 2.00 (50.8) 6 27.87 (708.0) Bottom Endwall Direct Feed Kit 23.69 (601.8) Sealing Provision 1.21 (30.7) Grade Level 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 V1-T6-26 1, 1-1/4, 1-1/2, 2 (25.4, 31.8, 38.1, 50.8) KO 1/2, 3/4, 1, 1-1/4, 1-1/2 (12.7, 19.1, 25.4, 31.8, 38.1) KO 28.70 (729.0) 28.01 (711.5) 6 1/2, 3/4, 1 (12.7, 19.1, 25.4) KO (2 Required) Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 6.3 Power Pedestals Mobile Home Panels Approximate Dimensions in Inches (mm) 6 6 Mobile Home Panel—Ring—Back-to-Back Mounting Front View Back View 11.25 (285.8) 10.75 (273.0) 14.45 (367.0) 6 Ring Type Socket Rated 200 A Continuous 6 6 1-1/4, 1-1/2, 2, 2-1/2 (31.8, 38.1, 50.8, 63.5) Knockout 57.81 (1468.3) ON 6 6 OFF ON OFF Door Not Shown 200A Main Breaker 5/16 (7.9) Diameter KO Door Not Shown 1-1/4, 1-1/2, 2, 2-1/2 (31.8, 38.1, 50.8, 63.5) KO (2) Required 1/2 (12.7) KO (3) Required 1, 1-1/4, 1-1/2, 2 (25.4, 31.8, 38.1, 50.8) Knockout 6 5/16 (7.9) Diameter KO (3) Required 6 50.08 (1272.1) 43.20 (1097.4) 22.01 (711.5) 6 3/4, 1 (19.1, 25.4) KO Optional Direct Feed Kit Shown Installed (Cover Not Shown) 27.87 (708.0) 23.69 (601.8) 18.69 (474.6) 6 Bottom Endwall Back Unit 28.70 (729.0) 25.00 (635.0) 6 1/2, 3/4 (12.7, 19.1) 1-1/2, 2, 2-1/2, 3 (38.1, 50.8, 63.5, 76.2) KO KO (2) Required Grade Level Sealing Provision 1/2, 3/4, 1 (12.7, 19.1, 25.4) KO (2) Required 6 1, 1-1/4, 1-1/2, 2 (25.4, 31.8, 38.1, 50.8) KO 6 1/2, 3/4, 1, 1-1/4, 1-1/2 (12.7, 19.1, 25.4, 31.8, 38.1) KO 6 6 Bottom Endwall Direct Feed Kit 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-27 6.4 6 Power Pedestals RV Park Hook-Ups Contents Recreational Vehicle/Campground Products Description 6 Power Pedestals Product Selection Guide . . . . . . . . . . . . . . . . . Powerhouse Power Pedestal . . . . . . . . . . . . . . . . Powerhouse—Stainless Steel (SS) Power Pedestal Newport Camp Mate Power Pedestal . . . . . . . . . Park Light Power Pedestal . . . . . . . . . . . . . . . . . . Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital Electronic Kilowatthour Meters . . . . . . . . . Distribution Equipment—Ground Fault Monitor . . Distribution Equipment—Substations. . . . . . . . . . Distribution Equipment—Panels . . . . . . . . . . . . . . Distribution Equipment—Transformers. . . . . . . . . 6 6 6 6 6 6 6 High-Quality, Weatherproof Electrical Equipment 6 6 Power Pedestals 6 Product Overview 6 6 6 6 6 6 6 6 6 6 On March 24, 2006, RV Park Hook-Ups® joined together with Eaton to provide unmatched products and services in the recreational vehicle industry, as well as the marina industry. Known as the leader in electrical control, power distribution, and industrial automation products and services, Eaton is a quality driven company that constantly looks for ways to provide enhanced products and service solutions for their customers. Eaton will be able to provide RV park developers a complete electrical solution. For more information on the other products available from Eaton, visit us online at www.eaton.com or www.rvparkhookups.com What Eaton has to Offer ● Complementary comprehensive in-house electrical designs for your complete RV or marina development ● RV and marina power pedestals ● Custom substations ● Transformers ● Panels ● Wire ● Digital electronic meters ● Receptacles and breakers ● Specialized electrical parts and equipment 6 6 6 6 6 6 6 6 V1-T6-28 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-29 V1-T6-30 V1-T6-33 V1-T6-36 V1-T6-39 V1-T6-42 V1-T6-44 V1-T6-45 V1-T6-46 V1-T6-49 V1-T6-50 6.4 Power Pedestals RV Park Hook-Ups Product Selection Guide 6 Power Receptacles 6 6 6 6 6 6 6 6 Power Outlets Side One 6 Maximum GFI Side Two Phase Powerhouse Powerhouse–SS Newport Camp Mate Park Light None None 1 2 2 2 2 30–20 00 1 2 2 1 1 30–20 30–20 1 2 2 — — 30–30–20 30–30–20 1 2 2 — — 30–20 50–20 1 2 2 — — 30–30–20 50–20 1 2 2 — — 30–30–20 30–50–20 1 2 2 — — 30–30–20 50–50–20 1 2 2 — — 30–50–20 30–50–20 1 2 2 — — 30–50–20 50–50–20 1 2 2 — — 50–20 None 1 2 2 — — 50–20 50–20 1 2 2 — — 50–50–20 50–20 1 2 2 — — 50–50–20 50–50–20 1 2 2 — — 30–50–20 None 1 2 2 0 — 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-29 6.4 6 Power Pedestals RV Park Hook-Ups Contents Powerhouse Power Pedestal Description 6 6 6 6 6 6 6 6 6 6 Powerhouse Power Pedestal 6 Product Description Features The Powerhouse® RV utility center is our most popular pedestal for single or double RV sites because of its full complement of standard features and available option packages able to meet any user requirement. The housing is made of durable weatherproof engineered resin and will never rust or deteriorate. ● 6 6 6 6 6 6 6 6 6 6 Page Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . Powerhouse Power Pedestal Standards and Certifications . . . . . . . . . . . . . . Catalog Number Selection . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Powerhouse—Stainless Steel (SS) Power Pedestal Newport Camp Mate Power Pedestal . . . . . . . . . Park Light Power Pedestal . . . . . . . . . . . . . . . . . . Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital Electronic Kilowatthour Meters . . . . . . . . . Distribution Equipment—Ground Fault Monitor . . Distribution Equipment—Substations. . . . . . . . . . Distribution Equipment—Panels . . . . . . . . . . . . . . Distribution Equipment—Transformers. . . . . . . . . That’s why it comes with a limited lifetime warranty. Since the Powerhouse can accommodate two RV sites, it’s an economical pedestal for double site installation. This unit is ideal for new, or when retrofitting, full-service RV parks. ● ● ● ● ● ● Photocell controlled 13 watt fluorescent light with amber lens Lockable weatherproof doors that protect receptacles and breakers Hose and cable brackets Engineered resin housing with a two-part polyurethane coating for a UV-resistant, long-lasting finish Limited lifetime warranty on the housing Loop-feed mechanical busbars that can accept up to 250 kcmil wire Hinged pedestal base providing easy access for installation and maintenance V1-T6-31 V1-T6-31 V1-T6-32 V1-T6-32 V1-T6-33 V1-T6-36 V1-T6-39 V1-T6-42 V1-T6-44 V1-T6-45 V1-T6-46 V1-T6-49 V1-T6-50 Available Options Surge Protection SurgeTrap is designed to protect electrical and electronic loads from transients and surge disturbances on your AC power line, such as voltage surges, spikes and lighting. The SurgeTrap has a lifetime warranty where Eaton will replace the SurgeTrap device at no charge. ● ● ● ● ● 175 kA maximum surge current 3500 joules Type 3R enclosure Comes with a protection working indicator light Factory installed integral to pedestal or available for retrofit 6 ● ● ● ● ● ● ● ● ● ● 6 ● 6 ● 6 ● 6 6 ● 6 ● 6 V1-T6-30 V1-T6-28 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Clear lens Photocell controlled single or dual 7 watt or 13 watt fluorescent light Telephone (RJ-11) for each side Cable TV for each side High-speed Internet connector (RJ-45) for each side Water—single or dual 1/4-turn brass ball valves (brass “T” connection) with 3/4-inch hose bibs Water meters with remote capability Water—anti-siphon faucet Loop-feed 3/8-inch stud lug copper busbar for up to 250 kcmil wire (recommended for salt water environments) Single-feed mechanical busbars for up to 250 kcmil wire Digital electronic meter for each side Wireless remote reading of electronic kilowatt meters Meter socket for each side powered (to accept glass style meter) Direct burial ground mounting stand stainless or galvanized Custom paint color Power Pedestals RV Park Hook-Ups 6.4 Standards and Certifications ● 6 UL/CSA listed 6 6 6 Catalog Number Selection 6 P D U 4 7 0 0 0 0 0 0 1 2 K M 6 Type P = Powerhouse Z = PHSS Lighting and Lens Color A = 7W light Amber B = Dual 7W light Amber C = 9W light Amber D = 13W light Amber E = Dual 13W light Amber F = No lighting Amber G = 7W light Clear H = Dual 7W light Clear I = 9W light Clear J = 13W light Clear K = Dual 13W light Clear L = No lighting Clear M = 7W light Special N = Dual 7W light Special O = 9W light Special P = 13W light Special Q = Dual 13W light Special R = No lighting Special S = 350 MA LED Amber T = 700 MA LED Amber U = 350 MA LED Clear V = 700 MA LED Clear W = 350 MA LED Special Y = 700 MA LED Special Metering Type U = Unmetered D = Digital electronic meters (side one) T = Digital electronic meters (side two) B = Digital electronic meters (both sides) R = Receptacles metered individually M = One meter socket (100A) N = Two meter socket (100A each) R2S2 R3S2 R4S2 R4S1 R3S1 0 0 0 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 8 8 8 = None = 20A GFI duplex = 30A, 125V = 50A, 125/250V = 100A, 208V = 100A, 250V = 100A, 277/480V = 100A, 480V R1S2 0 1 2 3 4 5 6 7 8 0 1 2 4 5 6 7 8 R2S1 R1S1 Sides and Receptacles 0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 Water Option 1 =0 =1 =2 = Single water meter = Dual water meter = Single meter, 2V = 1 frost free = 2 frost free Extra Unmetered GFI Receptacles 0 = None 1 =1 2 =2 6 Phone Cable TV and Internet Options Phone Cable TV Internet Jack Jack Option A= 1 0 0 B= 1 0 1 C= 1 0 2 D= 1 1 0 E= 1 1 1 F= 1 1 2 G= 1 2 0 H= 1 2 1 I= 1 2 2 J= 2 0 0 K= 2 0 1 L= 2 0 2 M= 2 1 0 N= 2 1 1 O= 2 1 2 P= 2 2 0 Q= 2 2 1 R= 2 2 2 S= 0 2 2 T= 0 0 1 U= 0 0 2 V= 0 1 0 W= 0 1 1 X= 0 1 2 Y= 0 2 0 Z= 0 2 1 0= 0 0 0 6 6 6 6 6 6 6 6 6 6 6 Bus S = Single-phase 3/8-inch copper busbar F = Three-phase 3/8-inch copper busbar C = Single-phase 3/8-inch Canadian busbar T = Three-phase 3/8-inch Canadian busbar M = Single-phase 300 kcmil mechanical lug bus Z = Three-phase 300 kcmil mechanical lug bus L = Single-phase 350 kcmil mechanical lug bus P = Three-phase 350 kcmil mechanical lug bus N = Single-phase 1/4-inch copper busbar Q = Single-phase 1/4-inch split mechanical busbar A = Single-phase 300 kcmil mechanical lug Canadian bus B = Three-phase 300 kcmil mechanical lug Canadian bus D = Single-phase 350 kcmil mechanical lug Canadian bus E = Three-phase 350 kcmil mechanical lug Canadian bus 6 6 6 6 6 6 Receptacle: R1S1 = Receptacle 1, Side 1 R2S1 = Receptacle 2, Side 1 R3S1 = Receptacle 3, Side 1 R1S2 = Receptacle 1, Side 2 R2S2 = Receptacle 2, Side 2 R3S2 = Receptacle 3, Side 2 6 Notes 1 Number represents the quantity of 1/4-turn ball valves with 3/4-inch hose bibs. 6 Internet option also available. Contact factory for details. 6 6 6 6 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-31 6.4 6 6 Power Pedestals RV Park Hook-Ups Accessories See Page V1-T6-75. Dimensions 6 Approximate Dimensions in Inches (mm) 6 Powerhouse 6 6 6 6 6 6 Top 6 6 44.00 (1117.6) 6 6 6 6 6 6 Side View Front View 6 6 6 6 6 6 6 13.75 (349.2) 6 Broken View 6 6 6 6 V1-T6-32 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Power Pedestals RV Park Hook-Ups Powerhouse—Stainless Steel (SS) Power Pedestal 6.4 Contents Description Page Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . Powerhouse Power Pedestal. . . . . . . . . . . . . . . . . Powerhouse—Stainless Steel (SS) Power Pedestal Catalog Number Selection . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Newport Camp Mate Power Pedestal . . . . . . . . . . Park Light Power Pedestal. . . . . . . . . . . . . . . . . . . Firehouse. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital Electronic Kilowatthour Meters . . . . . . . . . Distribution Equipment—Ground Fault Monitor . . Distribution Equipment—Substations . . . . . . . . . . Distribution Equipment—Panels . . . . . . . . . . . . . . Distribution Equipment—Transformers . . . . . . . . . V1-T6-28 V1-T6-30 V1-T6-34 V1-T6-35 V1-T6-35 V1-T6-36 V1-T6-39 V1-T6-42 V1-T6-44 V1-T6-45 V1-T6-46 V1-T6-49 V1-T6-50 6 6 6 6 6 6 6 6 6 6 6 Powerhouse—Stainless Steel (SS) Power Pedestal Product Description Features For long-lasting durability and low maintenance, the new stainless steel Powerhouse–SS pedestal is the most resilient power center offered. ● We have designed a stainless steel pedestal that will meet and exceed all applicable codes and withstand harsh inland and coastal environments. ● ● ● ● ● ● ● Stainless steel housing with a limited lifetime warranty Photocell controlled 13 watt fluorescent light with amber lens Large removable access panel for easy installation and maintenance Weatherproof doors that protect receptacles and breakers Backlit faceplate to aid in hooking up at night Hose and cable brackets Powder-coated finish Loop-feed mechanical busbars that can accept up to 350 kcmil wire Available Options ● ● ● ● ● ● ● ● ● ● Clear lens Photocell controlled single or dual 7 watt or 13 watt fluorescent light Telephone (RJ-11) for each side Cable TV for each side High-speed Internet connection (RJ-45) for each side Water–single or dual 1/4-turn brass ball valves (brass “T” connection) with 3/4-inch hose bibs Water meters with remote capability Water—anti-siphon faucet Direct burial stainless steel ground mounting stand Lockable doors ● ● ● ● ● ● Loop-feed 3/8-inch stud lug copper busbar for up to 350 kcmil wire (recommended for salt water environments) Single-feed mechanical busbars for up to 350 kcmil wire Digital electronic metering for each side Wireless remote reading of electronic kilowatt meters Meter socket for each side powered (to accept glass style meter) Four door design to add more outlets per pedestal 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-33 6.4 RV Park Hook-Ups Catalog Number Selection Z D U 4 7 0 0 0 0 0 0 1 2 K M 6 6 6 6 6 6 Metering Type U = Unmetered D = Digital electronic meters (side one) T = Digital electronic meters (side two) B = Digital electronic meters (both sides) R = Receptacles metered individually M = One meter socket (100A) N = Two meter socket (100A each) 6 6 6 6 6 6 6 6 6 6 6 0 1 2 3 4 5 6 7 8 0 1 2 4 5 6 7 8 0 0 0 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 8 8 8 = None = 20A GFI duplex = 30A, 125V = 50A, 125/250V = 100A, 208V = 100A, 250V = 100A, 277/480V = 100A, 480V R4S2 6 R3S2 6 Sides and Receptacles R2S2 6 R1S2 6 Lighting and Lens Color A = 7W light Amber B = Dual 7W light Amber C = 9W light Amber D = 13W light Amber E = Dual 13W light Amber F = No lighting Amber G = 7W light Clear H = Dual 7W light Clear I = 9W light Clear J = 13W light Clear K = Dual 13W light Clear L = No lighting Clear M = 7W light Special N = Dual 7W light Special O = 9W light Special P = 13W light Special Q = Dual 13W light Special R = No lighting Special S = 350 MA LED Amber T = 700 MA LED Amber U = 350 MA LED Clear V = 700 MA LED Clear W = 350 MA LED Special Y = 700 MA LED Special R4S1 6 R2S1 6 Type P = Powerhouse Z = PHSS R1S1 6 R3S1 6 Power Pedestals 0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 Water Option 1 =0 =1 =2 = Single water meter = Dual water meter = Single meter, 2V = 1 frost free = 2 frost free Extra Unmetered GFI Receptacles 0 = None 1 =1 2 =2 Phone Cable TV and Internet Options Phone Cable TV Internet Jack Jack Option A = 1 0 0 B = 1 0 1 C = 1 0 2 D = 1 1 0 E = 1 1 1 F = 1 1 2 G = 1 2 0 H = 1 2 1 I = 1 2 2 J = 2 0 0 K = 2 0 1 L = 2 0 2 M= 2 1 0 N= 2 1 1 O = 2 1 2 P = 2 2 0 Q = 2 2 1 R = 2 2 2 S = 0 2 2 T = 0 0 1 U = 0 0 2 V = 0 1 0 W= 0 1 1 X = 0 1 2 Y = 0 2 0 Z = 0 2 1 0 = 0 0 0 Bus S = Single-phase 3/8-inch copper busbar F = Three-phase 3/8-inch copper busbar C = Single-phase 3/8-inch Canadian busbar T = Three-phase 3/8-inch Canadian busbar M = Single-phase 300 kcmil mechanical lug bus Z = Three-phase 300 kcmil mechanical lug bus L = Single-phase 350 kcmil mechanical lug bus P = Three-phase 350 kcmil mechanical lug bus N = Single-phase 1/4-inch copper busbar Q = Single-phase 1/4-inch split mechanical busbar A = Single-phase 300 kcmil mechanical lug Canadian bus B = Three-phase 300 kcmil mechanical lug Canadian bus D = Single-phase 350 kcmil mechanical lug Canadian bus E = Three-phase 350 kcmil mechanical lug Canadian bus Receptacle: R1S1 = Receptacle 1, Side 1 R2S1 = Receptacle 2, Side 1 R3S1 = Receptacle 3, Side 1 R1S2 = Receptacle 1, Side 2 R2S2 = Receptacle 2, Side 2 R3S2 = Receptacle 3, Side 2 Notes 1 Number represents the quantity of 1/4-turn ball valves with 3/4-inch hose bibs. Internet option also available. Contact factory for details. 6 6 6 6 6 V1-T6-34 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Power Pedestals RV Park Hook-Ups 6.4 Accessories 6 See Page V1-T6-75. 6 Dimensions Approximate Dimensions in Inches (mm) 6 Powerhouse—Stainless Steel (SS) 6 6 6 6 6 6 6 6 6 6 40.00 (1016.0) 6 6 6 6 6 6 6 6 6 6 6 9.88 (251.0) 6 6 6 6 6 6 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-35 6.4 6 Power Pedestals RV Park Hook-Ups Contents Newport Camp Mate Power Pedestal Description 6 Page Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . Powerhouse Power Pedestal . . . . . . . . . . . . . . . . Powerhouse—Stainless Steel (SS) Power Pedestal Newport Camp Mate Power Pedestal Catalog Number Selection . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Park Light Power Pedestal . . . . . . . . . . . . . . . . . . Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital Electronic Kilowatthour Meters . . . . . . . . . Distribution Equipment—Ground Fault Monitor . . Distribution Equipment—Substations. . . . . . . . . . Distribution Equipment—Panels . . . . . . . . . . . . . . Distribution Equipment—Transformers. . . . . . . . . 6 6 6 6 6 6 6 V1-T6-28 V1-T6-30 V1-T6-33 V1-T6-37 V1-T6-38 V1-T6-38 V1-T6-39 V1-T6-42 V1-T6-44 V1-T6-45 V1-T6-46 V1-T6-49 V1-T6-50 6 6 Newport Camp Mate Power Pedestal 6 Product Description Features The Newport Camp Mate provides many of the features and options of our other fullsize pedestals, but in a compact self-contained unit. This model provides more mounting options to RV park owners than any other model. It can be mounted to our stainless steel stand either flanged or direct burial, a post or any wall. ● 6 6 6 6 6 6 6 6 6 It comes standard with a resin housing that will never rust or deteriorate and provides area lighting as well as aiding in hooking up at night. This unit is especially suitable to many RV park renovation projects as well as new RV parks. 6 6 ● ● ● ● ● ● Photocell controlled 7 watt fluorescent light with amber lens Lockable weatherproof door that protects receptacles and breakers Engineered resin housing Limited lifetime warranty on the housing Designed to mount on a post, wall or an optional custom stand Loop-feed 1/4-inch copper stud lug busbars that can accept 2/0 AWG wire for Camp Mate without optional stand Loop-feed mechanical busbars that can accept up to 2/0 AWG wire for Camp Mate on optional stand Available Options ● ● ● ● ● ● ● ● ● ● 6 ● 6 ● 6 ● 6 36-inch stainless steel stand 40-inch stainless steel pad-mounted stand 60-inch direct burial stainless steel stand Telephone (RJ-11) Cable TV High-speed Internet connector (RJ-45) Water—single or dual 1/4-turn brass ball valves (brass “T” connection) with 3/4-inch hose bibs mounted on optional stand Water—anti-siphon backflow preventer Loop feed 3/8-inch stud lug copper busbar for up to 350 kcmil wire with stand (recommended for salt water environments) Single-feed mechanical busbars for up to 350 kcmil wire available with stand Digital electronic meter Wireless remote reading of electronic kilowatt meter Meter socket available with aluminum stands (to accept glass style meter) 6 6 6 V1-T6-36 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Standards and Certifications The Newport Camp Mate is UL listed and comes with a limited lifetime warranty on the housing. Power Pedestals RV Park Hook-Ups 6.4 Catalog Number Selection 6 C A Y B U 4 3 0 1 1 2 W M Type N = NP Harbor Mate C = NP Camp Mate A C F G I L M O R S T U V W Y Lighting and Lens Color = 7W light Amber = 9W light Amber = No lighting Amber = 7W light Clear = 9W light Clear = No lighting Clear = 7W light Special = 9W light Special = No lighting Special = 350 MA LED Amber = 700 MA LED Amber = 350 MA LED Clear = 700 MA LED Clear = 350 MA LED Special = 700 MA LED Special Photocell Y = Yes N = No Lighting Protection B = Breaker protected F = Fuse protected Metering Type 1 U = Unmetered D = Digital electronic meters R = Receptacles metered individually Stand 0 =0 1 =1 Sides and Receptacles R1S1 R2S1 R3S1 0 0 0 1 1 1 2 2 3 3 4 4 0 = None 1 = 20A GFI duplex 2 = 30A, 125V 3 = 50A, 125V 4 = 50A, 125/250V 6 Bus S = Single-phase 1/4-inch copper busbar F = Three-phase 1/4-inch copper busbar C = Single-phase 1/4-inch Canadian busbar M = Mechanical lug 2/0 Q = Single-phase 1/4-inch split mechanical busbar (with stand ONLY) A = 1/4-inch Canadian mechanical Water Option 2 0 =0 1 =1 2 =2 6 6 6 6 6 6 6 Hard Wired Breakers 6 S1 0 = None 2 = 20A, two-pole 3 = 30A 6 6 Phone Cable TV and Internet Options Phone Jack Cable TV Jack Internet Option A = 1 0 0 B = 1 0 1 C = 1 0 2 D = 1 1 0 E = 1 1 1 (Camp Mate only) T = 0 0 1 V = 0 1 0 W= 0 1 1 0 = 0 0 0 6 6 6 6 Receptacle: R1 = Receptacle 1 R2 = Receptacle 2 R3 = Receptacle 3 6 6 Notes 1 20A GFIs not metered. 2 Number represents the quantity of 1/4-turn ball valves with 3/4-inch hose bibs (with stand only). 6 6 6 6 6 6 6 6 6 6 6 6 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-37 6.4 6 6 Power Pedestals RV Park Hook-Ups Accessories See Page V1-T6-75. Dimensions 6 Approximate Dimensions in Inches (mm) 6 Newport Camp Mate 6 0.12 (3.2) 0.12 (3.2) 9.18 (233.0) 9.18 (233.0) 6 6 10.38 (263.7) 10.38 (263.7) 6 6 6 7.44 (189.1) 10.52 (267.2) 7.44 (189.1) 10.52 (267.2) 6 15.28 (388.0) 6 6 14.53 (369.0) 14.53 (369.0) 13.63 (346.2) 12.88 (327.2) 6 6 6 4º 4º 10.38 (263.7) 10.38 (263.7) 9.59 (243.6) 6 6 6 6 6 1.54 (39.1) 4.02 (102.2) 2.37 (60.3) 1.68 (42.7) 6 6 1.68 (42.7) 3.40 (86.4) 6.70 (170.2) Newport Redesign 1.54 (39.1) 4.02 (102.2) 2.37 (60.3) 3.40 (86.4) 6.70 (170.2) Newport Redesign With Meters 6 6 6 6 6 6 6 V1-T6-38 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Power Pedestals RV Park Hook-Ups 6.4 Contents Park Light Power Pedestal Description Page Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . Powerhouse Power Pedestal. . . . . . . . . . . . . . . . . Powerhouse—Stainless Steel (SS) Power Pedestal Newport Camp Mate Power Pedestal . . . . . . . . . . Park Light Power Pedestal Catalog Number Selection . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Firehouse. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital Electronic Kilowatthour Meters . . . . . . . . . Distribution Equipment—Ground Fault Monitor . . Distribution Equipment—Substations . . . . . . . . . . Distribution Equipment—Panels . . . . . . . . . . . . . . Distribution Equipment—Transformers . . . . . . . . . V1-T6-28 V1-T6-30 V1-T6-33 V1-T6-36 V1-T6-40 V1-T6-41 V1-T6-41 V1-T6-42 V1-T6-44 V1-T6-45 V1-T6-46 V1-T6-49 V1-T6-50 6 6 6 6 6 6 6 6 6 6 6 Park Light Power Pedestal Product Description Features The elegant design of the Park Light complements park landscaping and provides essential lighting required for park safety and security for campground paths, walkways, recreational areas and even pools. The Park Light has the same 360 degree lighting design as the Powerhouse and a resin housing that will never rust or deteriorate. ● At 10¢/kWH, it will provide area lighting at a cost of less than 50¢/month and the bulbs will last for about three years. The Park Light is a perfect lighting fixture for any campground and especially for RV parks with Powerhouse utility centers. ● ● ● Photocell controlled dual 13 watt fluorescent light with amber lens Engineered resin housing with a two-part polyurethane coating for a UV-resistant, long-lasting finish Limited lifetime warranty on the housing Loop-feed 1/4-inch stud lug copper busbars that can accept 2/0 AWG wire Available Options ● ● ● ● ● ● ● ● ● ● ● Clear lens Photocell controlled single or dual 7 watt or 13 watt fluorescent light Phone (RJ-11) Cable TV High-speed Internet (RJ-45) Water faucet(s) with 3/4-inch hose bib Water—anti-siphon backflow preventer Digital electronic meter Wireless remote reading of electronic kilowatt meter Direct burial ground mounting stand Custom paint color Standards and Certifications The housing has a limited lifetime warranty, and the unit is UL listed. 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-39 6.4 6 Power Pedestals RV Park Hook-Ups Catalog Number Selection H D Y B D 4 7 0 1 2 A M 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Type H = Hatteras Light R = Park Light A B C D E F G H I J K L M N O P Q R S T U V W Y Lighting and Lens Color = 7W light Amber = Dual 7W light Amber = 9W light Amber = 13W light Amber = Dual 13W light Amber = No lighting Amber = 7W light Clear = Dual 7W light Clear = 9W light Clear = 13W light Clear = Dual 13W light Clear = No lighting Clear = 7W light Special = Dual 7W light Special = 9W light Special = 13W light Special = Dual 13W light Special = No lighting Special = 350 MA LED Amber = 700 MA LED Amber = 350 MA LED Clear = 700 MA LED Clear = 350 MA LED Special = 700 MA LED Special Photocell Y = Yes N = No Lighting Protection B = Breaker protected F = Fuse protected Metering Type 1 U = Unmetered D = Digital electronic meters R = Receptacles metered individually Sides and Receptacles R1S1 R2S1 R1S2 0 0 0 1 1 1 2 2 2 3 3 3 4 4 4 0 = None 1 = 20A GFI duplex 2 = 30A, 125V 3 = 50A, 125V 4 = 50A, 125/250V Water Option 2 0 =0 1 = 1 (1/2-inch) 2 = 2 (1/2-inch) 3 = 1 (3/4-inch) 4 = 2 (3/4-inch) Hard Wired Breakers S1 0 = None 2 = 20A, two-pole 3 = 30A Bus S = Single-phase 1/4-inch copper busbar F = Three-phase 1/4-inch copper busbar C = Single-phase 1/4-inch Canadian busbar M = Mechanical lug 2/0 A = 1/4-inch Canadian mechanical Phone Cable TV and Internet Options Phone Cable TV Internet Jack Jack Option A = 1 0 0 B = 1 0 1 C = 1 0 2 D = 1 1 0 E = 1 1 1 F = 1 1 2 G = 1 2 0 H = 1 2 1 I = 1 2 2 J = 2 0 0 M= 2 1 0 P = 2 2 0 S = 0 2 2 T = 0 0 1 U = 0 0 2 V = 0 1 0 W= 0 1 1 X = 0 1 2 Y = 0 2 0 Z = 0 2 1 Receptacle: R1 = Receptacle 1, Side 1 R2 = Receptacle 2, Side 2 Notes 1 20A GFIs not metered. 2 Number represents the quantity of 1/4-turn ball valves with 3/4-inch hose bibs (with stand only). 6 6 6 6 6 6 6 6 6 6 6 6 6 V1-T6-40 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Power Pedestals RV Park Hook-Ups 6.4 Accessories 6 See Page V1-T6-75. 6 Dimensions Approximate Dimensions in Inches (mm) 6 6 Park Light 6 6 6 6 6 6 Busbar Access Top Removed 6 Inside Top 6 13.39 (340.2) 6 6 6 6 6 6 6 6 6 30.98 (786.9) 6 6 6 6 6 6 6 7.90 (200.7) 7.90 (200.7) Side View Front View Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 6 6 V1-T6-41 6.4 6 Power Pedestals RV Park Hook-Ups Contents Firehouse Description 6 Page Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . Powerhouse Power Pedestal . . . . . . . . . . . . . . . . Powerhouse—Stainless Steel (SS) Power Pedestal Newport Camp Mate Power Pedestal . . . . . . . . . Park Light Power Pedestal . . . . . . . . . . . . . . . . . . Firehouse Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital Electronic Kilowatthour Meters . . . . . . . . . Distribution Equipment—Ground Fault Monitor . . Distribution Equipment—Substations. . . . . . . . . . Distribution Equipment—Panels . . . . . . . . . . . . . . Distribution Equipment—Transformers. . . . . . . . . 6 6 6 6 6 6 6 V1-T6-28 V1-T6-30 V1-T6-33 V1-T6-36 V1-T6-39 V1-T6-43 V1-T6-43 V1-T6-44 V1-T6-45 V1-T6-46 V1-T6-49 V1-T6-50 6 6 Firehouse 6 Product Description 6 6 6 6 The Firehouse is designed to provide added fire safety to RV parks and campgrounds. The Firehouse provides a convenient location and easy access to fire extinguishers and to an optional life ring when installed around pools and waterfront amenities. 6 6 6 Features In addition, the Firehouse provides area lighting for easy identification during an emergency and for security lighting around the unit. The Firehouse can be equipped with an alarm strobe light and siren, which are automatically activated when the fire extinguisher cabinet door is opened or the optional life ring is removed. ● ● ● ● ● Available Options Photocell controlled 13 watt fluorescent light Amber lens for bug reduction 10 lb ABC Type fire extinguisher Stainless steel housing with oven-baked enamel finish with an engineered resin base and top Limited lifetime warranty on the housing ● ● ● Alarm strobe light and siren Optional 24-inch white or orange life ring for poolside or dockside installations 20 lb ABC Type fire extinguisher Catalog Number Selection F A Y A E N 6 6 Type F = Firehouse Photocell Y = Yes N = No 6 6 6 A B C D E F G H 6 6 6 = 7W light = Dual 7W light = 9W light = 13W light = Dual 13W light = No lighting = 7W light = Dual 7W light Alarm/Strobe A = Include alarm/strobe N = No alarm/strobe Amber Amber Amber Amber Amber Amber Clear Clear 24-Inch Life Ring R = Include life ring N = No life ring Fire Extinguisher E = Include 10 lb extinguisher N = No extinguisher X = Include 20 lb extinguisher Lighting and Lens Color I = 9W light Clear J = 13W light Clear K = Dual 13W light Clear L = No lighting Clear M = 7W light Special N = Dual 7W light Special O = 9W light Special P = 13W light Special Q = Dual 13W light R = No lighting S = 350 MA LED T = 700 MA LED U = 350 MA LED V = 700 MA LED W = 350 MA LED Y = 700 MA LED Special Special Amber Amber Clear Clear Special Special 6 6 6 V1-T6-42 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Power Pedestals RV Park Hook-Ups 6.4 Accessories 6 See Page V1-T6-75. 6 Dimensions Approximate Dimensions in Inches (mm) 6 6 Firehouse–SS 6 6 6 6 6 6 6 6 6 6 40.74 (1034.9) 6 6 6 6 6 6 6 6 6 6 9.88 (250.8) 6 11.54 (293.0) 6 6 6 6 6 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-43 6.4 6 Power Pedestals RV Park Hook-Ups Contents Digital Electronic Kilowatthour Meters Description 6 Page Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . Powerhouse Power Pedestal . . . . . . . . . . . . . . . . Powerhouse—Stainless Steel (SS) Power Pedestal Newport Camp Mate Power Pedestal . . . . . . . . . Park Light Power Pedestal . . . . . . . . . . . . . . . . . . Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital Electronic Kilowatthour Meters Distribution Equipment—Ground Fault Monitor . . Distribution Equipment—Substations. . . . . . . . . . Distribution Equipment—Panels . . . . . . . . . . . . . . Distribution Equipment—Transformers. . . . . . . . . 6 6 6 6 6 V1-T6-28 V1-T6-30 V1-T6-33 V1-T6-36 V1-T6-39 V1-T6-42 V1-T6-45 V1-T6-46 V1-T6-49 V1-T6-50 6 6 6 6 Digital Electronic Kilowatthour Meters 6 Product Description Features Available Options Using the latest surface mount technology, Eaton manufactures a digital electronic kilowatt hour meter that exceeds the +/– 2% accuracy required by ANSI (American National Standards Institute) C-12.1 and is approved by the state of California at +/– 1% over the full range of 0–100A from a 0.5 to 1 power factor and is available for both single- and three-phase applications. Our meter is designed to be user friendly in that all connections from external sources and the meter output are through one 14-pin locking connector. This feature eliminates many common problems, such as reverse line polarity and improper coil polarity. Simple LEDs, both red and green, indicate line and load condition and the pulsed LED indicates the rate of power consumption. ● 6 6 6 6 6 6 6 6 6 6 6 6 The meter drives an electromechanical counter that requires a 12V pulse each tenth of a kilowatthour, providing 10 pulses per kilowatt used. The meter output can be hard wired or connected to a transmitter in the pedestal for wireless transmission to a receiver displaying the output on a PC for direct billing of up to 1,000 individual customers 6 6 6 ● ● ● ● Wireless System All of our meters are “wireless capable” to allow for wireless meter reading. This technology enables the marina or RV park to get meter readings from one central location rather than visiting every site to read the counters. Meter Socket Capabilities Meter sockets are available on the Powerhouse and Powerhouse–SS. Standard: ● Four jaw ● Ring-type ● 100A 6 6 6 V1-T6-44 Product Selection 200A (SS only) Lockable hasp Ringless (SS only) Five jaw Seven jaw (SS only) Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com One Element Meter Two Element Meter Three Element Meter Power Pedestals RV Park Hook-Ups 6.4 Contents Ground Fault Monitor Description Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . Powerhouse Power Pedestal. . . . . . . . . . . . . . . . . Powerhouse—Stainless Steel (SS) Power Pedestal Newport Camp Mate Power Pedestal . . . . . . . . . . Park Light Power Pedestal. . . . . . . . . . . . . . . . . . . Firehouse. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital Electronic Kilowatthour Meters . . . . . . . . . Distribution Equipment—Ground Fault Monitor Distribution Equipment—Substations . . . . . . . . . . Distribution Equipment—Panels . . . . . . . . . . . . . . Distribution Equipment—Transformers . . . . . . . . . Page V1-T6-28 V1-T6-30 V1-T6-33 V1-T6-36 V1-T6-39 V1-T6-42 V1-T6-44 V1-T6-46 V1-T6-49 V1-T6-50 6 6 6 6 6 6 6 6 6 6 Distribution Equipment—Ground Fault Monitor 6 Product Description Features New to our product offering are ground fault monitoring systems designed to detect fault currents in the AC shore power system that are too low to trip a circuit breaker. The Ground Fault Monitor helps reduce the risk of injury or property damage, which may result from stray fault currents. Our ground fault monitoring system provides information to the maintenance staff on the overall condition of the AC electrical system. The ground fault monitoring system operates 24 hours a day and can be monitored by nontechnical personnel. 6 ● ● ● ● ● UL listed current transformers Adjustable trip level 10 mA to 10A Current transformers up to 8 1/4-inch diameter Visual and/or audible alarm Housing of fiberglass or powder coated stainless steel available 6 6 6 6 6 Power Guard The ground fault monitor detects ground fault currents by means of current transformers (CT), which are placed around main or branch circuits. If a ground fault occurs, the CT will detect the amount of fault current and send a signal to the ground fault monitoring device where the amount of fault current is displayed with the faulty circuit identified. The detected fault can either activate an indicator alarm or disconnect the faulted circuit. 6 6 6 6 6 6 6 6 6 6 6 6 6 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-45 6.4 6 Power Pedestals RV Park Hook-Ups Contents Substations Description 6 6 6 6 6 6 6 6 Side-by-Side Substation 6 6 Distribution Equipment—Substations 6 Product Description Application Description The introduction of substations into the marina and recreational vehicle market allows Eaton to be your complete marina and RV park electrical products supplier. We are able to assist in the design and layout of your marina or RV park electrical system from the primary service provider to your power pedestal. Our substations are designed for any coastal or inland environment and are constructed of powdercoated stainless steel NEMA 3R housing cabinets. All substation cabinets come with our limited lifetime warranty. All of our substations use Eaton’s panels and circuit breakers, providing our customers the utmost in circuit protection and quality. The aluminum and Galvaneal cabinets are recommended for inland applications. The substations can be configured with 50 to 330 kVA single-phase or three-phase copper wound transformers and up to 20 single-phase or 12 threephase branch breakers. An optional three-sided doublewall cabinet is available that provides air flow between the panels. All substations come standard with temperaturecontrolled cooling fans. 6 6 6 6 6 6 6 6 6 6 6 6 Page Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . Powerhouse Power Pedestal . . . . . . . . . . . . . . . . Powerhouse—Stainless Steel (SS) Power Pedestal Newport Camp Mate Power Pedestal . . . . . . . . . Park Light Power Pedestal . . . . . . . . . . . . . . . . . . Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital Electronic Kilowatthour Meters . . . . . . . . . Distribution Equipment—Ground Fault Monitor . . Distribution Equipment—Substations Features, Benefits and Functions . . . . . . . . . . Available Options . . . . . . . . . . . . . . . . . . . . . . . Standards and Certifications . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Distribution Equipment—Panels . . . . . . . . . . . . . . Distribution Equipment—Transformers. . . . . . . . . Product Selection Guide Panel and Transformer Combinations Panel Transformer Single-Phase 200A 50 kVA 300A 75 kVA 400A 100 kVA 600A 150 kVA 700A 167.5 kVA 800A 200 kVA 1000A 250 kVA 1200A 330 kVA Three-Phase 100A 45 kVA 200A 75 kVA 300A 112.5 kVA 400A 150 kVA 600A 225 kVA 800A 300 kVA 6 6 6 6 6 6 V1-T6-46 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-28 V1-T6-30 V1-T6-33 V1-T6-36 V1-T6-39 V1-T6-42 V1-T6-44 V1-T6-45 V1-T6-47 V1-T6-48 V1-T6-48 V1-T6-48 V1-T6-49 V1-T6-50 Power Pedestals RV Park Hook-Ups 6.4 Features, Benefits and Functions ● ● ● ● Limited lifetime warranty on the housing All stainless steel hardware Temperature controlled cooling fans in the transformer and circuit breaker compartments Lockable door Ventilation The substation ventilation is designed to optimize air circulation over and around the transformers and through the panel compartment so that the substation operates at lower temperatures. Substations come equipped with temperature-controlled cooling fans for exhausting hot air from the cabinet and solar shield. 6 Substations 6 Temperature-controlled fans for cooling Stainless steel housing with polyester powder coating 6 6 6 6 6 6 Limited lifetime warranty on the housing 6 6 Stainless steel hardware with locking doors 6 6 6 In addition, substations are available with a doublewalled cabinet and solar shield, which allow for cooling of both the exterior surface of the cabinet and the internal components. 6 6 6 6 6 Custom made to your specifications: Single-phase or three-phase copper wound transformers 50 to 330 kVA Up to 1200A main circuit breaker with 20 single-phase or 12 three-phase branch circuit breakers 6 6 Sun Heat 6 6 6 Air Transformers 6 Double-Walled Stainless 6 6 6 6 Cool Air 6 Double-Walled Construction 6 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-47 6.4 6 ● ● 6 6 ● 6 6 6 ● ● 6 ● 6 ● 6 ● 6 6 ● 6 6 6 6 6 RV Park Hook-Ups Available Options 6 6 Power Pedestals ● ● Powder-coated cabinets made of stainless steel or fiberglass Limited lifetime warranty on housing. Transformer and secondary distribution panel in a single enclosure have a one-year limited warranty Stainless steel housing and hardware with locking doors Single-phase and threephase models Overload capacity meets ANSI L57.96–01.250 Optional double-walled construction Temperature-controlled fans for cooling Custom-made copper wound single-phase or three-phase transformers from 50 to 330 kVA Up to 1200A main circuit breaker with 15 singlephase branch circuit breakers or 10 three-phase branch circuit breakers Substations can be equipped with photocells to turn on and off lights A 20A GFI can be installed in the cabinet, as well as a ground fault monitoring system Standards and Certifications ● cULus listed Dimensions Approximate Dimensions in Inches (mm) Substations Standard Substation Height 53.00 (1346.2) Width 51.00 (1295.4) Depth 33.00 (838.2) Side-by-Side Substation Height 53.00 (1346.2) Width 66.00 (1676.4) Depth 30.00 (762.0) Double Panel Substation Height 53.00 (1346.2) Width 63.00 (1600.2) Depth 33.00 (838.2) 6 6 6 6 6 6 6 6 6 6 6 6 V1-T6-48 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Power Pedestals RV Park Hook-Ups 6.4 Contents Panels Description Page Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . Powerhouse Power Pedestal. . . . . . . . . . . . . . . . . Powerhouse—Stainless Steel (SS) Power Pedestal Newport Camp Mate Power Pedestal . . . . . . . . . . Park Light Power Pedestal. . . . . . . . . . . . . . . . . . . Firehouse. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital Electronic Kilowatthour Meters . . . . . . . . . Distribution Equipment—Ground Fault Monitor . . Distribution Equipment—Substations . . . . . . . . . . Distribution Equipment—Panels Distribution Equipment—Transformers . . . . . . . . . V1-T6-28 V1-T6-30 V1-T6-33 V1-T6-36 V1-T6-39 V1-T6-42 V1-T6-44 V1-T6-45 V1-T6-46 V1-T6-50 6 6 6 6 6 6 6 6 6 6 6 Distribution Equipment—Panels Product Description Features We now can offer our customers Eaton’s PRL-3A and PRL-4 panels as standalone units or in one of our substations. All of our busses are made of copper and are load rated, breakers are bolton type. Distribution panels can be single-phase or threephase based on your system requirements. Distribution panels can also have a main breaker or a main lug. Branch circuit breakers are provided based on customer requirements. ● ● ● All internal wiring is fine stranded 2000V insulated copper Copper busbars All exterior hardware is stainless steel Available Options ● ● ● ● ● ● NEMA 3R or 4X Powder-coated stainless steel Main breaker up to 1200A Branch breaker 20 to 1200A Main lug only We also offer 480V models—single-phase and three-phase Standards and Certifications ● ● UL listed cULus listed 6 6 6 6 6 6 6 Single-Phase ● Up to 1200A main circuit breakers ● Up to 42 branch circuit breakers 6 6 6 Three-Phase ● Up to 1200A main circuit breakers ● Up to 42 branch circuit breakers 6 6 6 6 6 6 6 6 6 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-49 6.4 6 Power Pedestals RV Park Hook-Ups Contents Transformers Description 6 Page Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection Guide . . . . . . . . . . . . . . . . . Powerhouse Power Pedestal . . . . . . . . . . . . . . . . Powerhouse—Stainless Steel (SS) Power Pedestal Newport Camp Mate Power Pedestal . . . . . . . . . Park Light Power Pedestal . . . . . . . . . . . . . . . . . . Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital Electronic Kilowatthour Meters . . . . . . . . . Distribution Equipment—Ground Fault Monitor . . Distribution Equipment—Substations. . . . . . . . . . Distribution Equipment—Panels . . . . . . . . . . . . . . Distribution Equipment—Transformers 6 6 6 6 6 6 V1-T6-28 V1-T6-29 V1-T6-30 V1-T6-33 V1-T6-36 V1-T6-39 V1-T6-42 V1-T6-44 V1-T6-45 V1-T6-46 V1-T6-49 6 6 6 Distribution Equipment—Transformers 6 Product Description Features Because of the high humidity and corrosive conditions of coastal environments, our transformers are wound with Class H heavily insulated copper bar and are double dipped in tough insulating varnish that protects the copper, as well as reduces the hum that is typical in a transformer that is not double dipped. For marine applications, we provide a third overcoat of high temperature epoxy to protect against the severe saltwater environment. We can provide this transformer in singlephase, from 50–500 kVA, and three-phase, from 45–300 kVA. ● 6 6 6 6 6 6 6 6 6 6 ● ● ● Copper wound transformer coils double dipped in high temperature baking varnish Copper terminations Marine transformers with epoxy overcoat All copper-to-copper connections Available Options ● ● ● Single-phase: 50–500 kVA Three-phase: 45–300 kVA Epoxy overcoat for nonmarine applications Primary Voltages ● 480 wye three-phase ● 480V three-phase delta three-wire + ground ● 480V single-phase two-wire + ground Secondary Voltages ● 127/220V three-phase wye four-wire ● 120/208V three-phase wye four-wire ● 120/240V single-phase three-wire Marina Power Distribution Transformer kVA Availabilities ● Single-phase: 50, 75, 100, 150, 167.5, 200, 250, 330, 500 kVA ● Three-phase: 45, 75, 112.5, 150, 225, 300 kVA 6 6 6 6 6 6 6 6 V1-T6-50 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Standards and Certifications ● cULus listed Power Pedestals Marina Power and Lighting Equipment 6.5 Contents Marina Power and Lighting Equipment Description High-Quality, Weatherproof Electrical Equipment Power Pedestals Product Selection Guide. . . . . . . . . . . . . . . . . . Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . Hatteras Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mariner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital Electronic Kilowatthour Meters . . . . . . . . . Distribution Equipment—Ground Fault Monitor . . Distribution Equipment—Mega Yacht Powerpoint Distribution Equipment—Substations . . . . . . . . . . Distribution Equipment—Panels . . . . . . . . . . . . . . Distribution Equipment—Transformers . . . . . . . . . Page V1-T6-52 V1-T6-54 V1-T6-58 V1-T6-62 V1-T6-65 V1-T6-69 V1-T6-73 V1-T6-79 V1-T6-80 V1-T6-81 V1-T6-82 V1-T6-83 V1-T6-86 V1-T6-89 V1-T6-90 Learn Online 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Power Pedestals 6 Product Overview Known as a leader in electrical control, power distribution, and industrial automation products and services, Eaton is a quality driven company that constantly looks for ways to provide enhanced product and service solutions for their customers. Eaton will be able to provide Marina developers a complete electrical solution. For more information on the other products available from Eaton, visit us online at www.eaton.com or www.marinapower.com. What Eaton has to Offer ● Eaton has more marina power outlets in service than all other suppliers combined ● We offer complementary comprehensive in-house electrical designs for your complete marina development using all high quality Eaton products ● We can provide your marina development with complete remote wireless digital electronic meter reading ● Not only can Eaton provide your marina with the highest quality power pedestals and marine distribution equipment, we can also supply your entire electrical needs for your surrounding development and beyond from safety switches to loadcenters and much more 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-51 6.5 6 6 Power Pedestals Marina Power and Lighting Equipment Product Selection Guide Power Pedestal Quick Guide 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Newport Hatteras Light Harbor Mate Lighthouse Lighthouse–SS Admiral–SS Firehouse Mariner Lookout Power Point Main housing Engineered resin Stainless steel Engineered resin Engineered resin Stainless steel Stainless steel Engineered resin Stainless steel Stainless steel Top Engineered resin Engineered resin Engineered resin Engineered resin Stainless steel Engineered resin Engineered resin Stainless steel Stainless steel Optional stand — — — Stainless steel — — PVC — — External hardware Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Stainless steel Standard lightwattage(s) 13W 13W 13W 7W 13W 13W 5W, 7W & 13W — 13W Yes LED lighting option Yes Yes Yes No Yes Yes No No Photocell Yes Yes Yes Yes Yes Yes No No Yes Lockable doors Yes Yes Yes Yes Yes — — — Yes Hose hangers Yes Yes No No Yes No No No No Electric meters Yes—up to 4 Yes—up to 4 Yes—up to 2 Yes—up to 2 Yes—up to 4 No No No Yes—up to 6 Remote meter reading Yes Yes Yes Yes Yes No No No Yes Water Two 3/4” Two 3/4” Two 1/2” Two 3/4” Two 3/4” None None None One 3/4” or more Water meters Yes Yes No Yes Yes No No No Yes Telephone Yes Yes Yes Yes Yes No No No Yes Cable TV Yes Yes Yes Yes Yes No No No Yes Internet Yes Yes Yes Yes Yes No No No Yes Fire extinguisher No No No No No Yes—up to 20 lbs No No No Life ring No No No No No Yes—24” No No No Alarm and strobe light No No No No No Yes No No No 20A 110V GFI Yes Yes Yes Yes Yes No No No Yes 30A 125V twist—lock Yes Yes Yes Yes Yes No No No Yes Yes 50A 125/250V twist—lock Yes Yes Yes Yes Yes No No No 100A 120/240V pin and sleeve Yes Yes No No Yes No No No Yes 100A 120/208V pin and sleeve Yes Yes No No Yes No No No Yes 100A 277/480V pin and sleeve Yes Yes No No Yes No No No Yes 100A 480V pin and sleeve Yes Yes No No Yes No No No Yes 200A 480V pin and sleeve No No No No Yes No No No Yes Hardwire compatible No No No No No No No No Yes Yes TVSS compatible Yes Yes No No Yes No No No Card swipe compatible Yes Yes No Yes Yes No No No Yes Security camera compatible No No No No No No No Yes No Up to 800A Busbar rating Up to 500A Up to 500A Up to 140A Up to 140A Up to 500A — — — Maximum wire size—single feed 350 kcmil 350 kcmil #2/0 #2/0 350 kcmil — — — (3) 500 kcmil Maximum wire size—loop feed #4/0 #4/0 #1 #1 350 kcmil — — — (3) 500 kcmil Height 44” 40” 30” 36” 48” 43.5” 24” to 72” 72” to 96” 50” Width 13.75” 9.875” 7.5” 10.5” 14” 9.875” 7” 9” 50” Depth 13.75” 9.875” 7.5” 14.5” 14” 9.875” 7” 9” 36” 6 Warranty Housing Limited lifetime Limited lifetime Limited lifetime Limited lifetime Limited lifetime Limited lifetime Limited lifetime Limited lifetime Limited lifetime 6 Receptacles and breakers 2 years 2 years 2 years 2 years 2 years — — — 2 years Lighting assembly 1 year 1 year 1 year 1 year 1 year 1 year 1 year — 1 year 6 6 6 V1-T6-52 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Power Pedestals Marina Power and Lighting Equipment Receptacles Receptacle Configuration Availability Side One None 6.5 Lighthouse Side Two None None Lighthouse–SS Admiral–SS None Receptacle Available with GFI Receptacles Hatteras Light Newport Harbor Mate 30A None None None Yes Yes Yes Yes Yes 30A 30A None None Yes Yes Yes Yes Yes 30A None 30A None Yes Yes Yes No Yes 30A 30A 30A 30A Yes Yes Yes Yes No 30A 50A None None Yes Yes Yes No No 30A None 50A None Yes Yes Yes No Yes 30A 50A 30A 50A Yes Yes Yes Yes 1 No 50A None None None Yes Yes Yes No No 50A 50A None None Yes Yes Yes Yes Yes 50A None 50A None Yes Yes Yes No Yes 50A 50A 50A 50A Yes Yes Yes No No 100A 120/240V None None None Yes Yes Yes No No 100A 120/240V None 50A-50A None Yes Yes Yes No No 100A 120/240V None 100A 120/240V None Yes Yes Yes No No 100A 120/240V 50A-50A 100A 120/240V 50A-50A Yes Yes Yes No No 100A 120/208V None None None No No Yes No No 100A 120/208V None 100A 120/240V None Yes Yes Yes No No 100A 120/240V 100A 120/240V 100A 120/240V 100A 120/240V Yes Yes Yes No No 100A 120/208V 100A 120/208V 100A 120/208V 100A 120/208V No No Yes No No 100A 120/240V 100A 120/240V 100A 120/208V 100A 120/208V No No Yes No No No No Yes No No 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Note 1 Configuration available with no additional GFI receptacles. 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-53 6.5 6 Power Pedestals Marina Power and Lighting Equipment Contents Lighthouse Description 6 Power Pedestals. . . . . . . . . . . . . . . . . . . . . . . . . . . Lighthouse Available Options. . . . . . . . . . . . . . . . . . . . . . . . Catalog Number Selection . . . . . . . . . . . . . . . . Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . Hatteras Light. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mariner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital Electronic Kilowatthour Meters . . . . . . . . . . Distribution Equipment—Ground Fault Monitor. . . Distribution Equipment—Mega Yacht Powerpoint . Distribution Equipment—Substations . . . . . . . . . . Distribution Equipment—Panels . . . . . . . . . . . . . . Distribution Equipment—Transformers . . . . . . . . . 6 6 6 6 6 6 6 6 6 6 6 6 Lighthouse 6 Product Description 6 6 6 6 6 6 6 6 6 6 One of our most popular units, the all-purpose Lighthouse® pedestal has a wide range of features. With units in service around the world, this stylish power pedestal is recognized for its practicality and exceptional durability. Engineered to withstand the most severe weather conditions, Lighthouse power pedestals can be found in marinas from Alaska to the tropics. Note: Custom paint color. Note: Wireless remote reading of electronic kilowatt meters. Features, Benefits and Functions ● ● ● ● ● ● Note: Clear lens. ● 6 Photocell controlled 13 watt fluorescent light (clear lens or amber lens for bug reduction) Lockable weatherproof doors that protect breakers and receptacles while in use (a requirement of NFPA 303 and NEC Article 555) Hose and cable brackets Heavy resin housing with a two-part polyurethane coating for a UV-resistant, long-lasting finish Copper busbar with ratings from 250 to 500A New “hingeless” base providing easy access for both installation and maintenance Backlit faceplate for easy receptacle plug-in at night 6 6 6 6 V1-T6-54 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Page V1-T6-51 V1-T6-55 V1-T6-56 V1-T6-57 V1-T6-57 V1-T6-58 V1-T6-62 V1-T6-65 V1-T6-69 V1-T6-73 V1-T6-79 V1-T6-80 V1-T6-81 V1-T6-82 V1-T6-83 V1-T6-86 V1-T6-89 V1-T6-90 Power Pedestals Marina Power and Lighting Equipment Lighthouse 6.5 Available Options ● 360° controlled 13 watt fluorescent light with amber lens for bug reduction ● ● Digital electronic metering for each side Lockable weatherproof doors that protect breakers and receptacles 6 Digital electronic metering (one, two or three element meters available) Built-in meter socket 20A/125V GFI receptacle (max. of two GFI receptacles per pedestal) 6 6 6 Note: 20A GFI receptacles are not to be used for shore power. Receptacle configuration available 30A, 50A, 30A/30A, 30A/50A, 50A/50A, 100A, Empty Note: Custom configurations also available ● ● Hose and cable brackets ● 1/4-inch Resin housing with a two-part polyurethane coating for a UV resistant, long-lasting finish 20A/125V GFI receptacle ● Phone and cable TV connections High-speed Internet connections (RJ45) for each side ● ● ● ● ● ● 6 6 High-speed Internet connections Wireless remote metering for electric and water Transient voltage surge suppressor (TVSS) to protect from voltage surges, spikes or lightning on the AC power line (extends warranty on internal parts to three years) Stainless steel door hinge on receptacle main doors Single or dual steel 1/4-turn ball valves with 3/4-inches Hose bibs and stainless steel handles Single or dual phone and/or cable TV connections Base cap Base extension LED lighting 6 6 6 6 6 6 6 6 6 6 6 6 Copper Busbar with Ratings from 250 to 500A 6 Cable and Internet Connections 6 6 6 6 New Hingeless Base 6 Optional Meter Socket 6 6 6 6 6 6 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-55 6.5 Marina Power and Lighting Equipment Catalog Number Selection L D U 4 7 0 0 0 0 0 0 1 2 K M 6 6 Type L = Lighthouse S = LHSS 6 6 6 6 6 Metering Type U = Unmetered D = Digital electronic meters (side one) T = Digital electronic meters (side two) B = Digital electronic meters (both sides) R = Receptacles metered individually M = One meter socket (100A) N = Two meter socket (100A each) V = 200A meter socket 6 6 6 6 6 6 6 6 6 6 0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8 0 0 0 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 8 8 8 = None = 20A GFI duplex = 30A, 125V = 50A, 125V = 50A, 125/250V = 100A, 208V = 100A, 250V = 100A, 277/480V = 100A, 480V R4S2 6 R3S2 6 Sides and Receptacles R2S2 6 R1S2 6 Lighting and Lens Color = 7W light Amber = Dual 7W light Amber = 9W light Amber = 13W light Amber = Dual 13W light Amber = No lighting Amber = 7W light Clear = Dual 7W light Clear = 9W light Clear = 13W light Clear = Dual 13W light Clear = No lighting Clear = 7W light Special = Dual 7W light Special = 9W light Special = 13W light Special = Dual 13W light Special = No lighting Special = 350 MA LED Amber = 700 MA LED Amber = 350 MA LED Clear = 700 MA LED Clear = 350 MA LED Special = 700 MA LED Special R4S1 A B C D E F G H I J K L M N O P Q R S T U V W Y R2S1 6 R1S1 6 R3S1 6 Power Pedestals 0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 Water Option 1 =0 =1 =2 = Single water meter = Dual water meter = Single meter, 2V = 1 frost free = 2 frost free Extra Unmetered GFI Receptacles 2 0 = None 1 =1 2 =2 Phone Cable TV and Internet Options Phone Cable TV Internet Jack Jack Option A = 1 0 0 B = 1 0 1 C = 1 0 2 D = 1 1 0 E = 1 1 1 F = 1 1 2 G = 1 2 0 H = 1 2 1 I = 1 2 2 J = 2 0 0 K = 2 0 1 L = 2 0 2 M= 2 1 0 N = 2 1 1 O = 2 1 2 P = 2 2 0 Q = 2 2 1 R = 2 2 2 S = 0 2 2 T = 0 0 1 U = 0 0 2 V = 0 1 0 W= 0 1 1 X = 0 1 2 Y = 0 2 0 Z = 0 2 1 0 = 0 0 0 Bus S = Single-phase 3/8-inch copper busbar F = Three-phase 3/8-inch copper busbar C = Single-phase 3/8-inch Canadian busbar T = Three-phase 3/8-inch Canadian busbar M = Single-phase 300 kcmil mechanical lug bus Z = Three-phase 300 kcmil mechanical lug bus L = Single-phase 350 kcmil mechanical lug bus P = Three-phase 350 kcmil mechanical lug bus N = Single-phase 1/4-inch copper busbar Q = Single-phase 1/4-inch split mechanical busbar Receptacle: R1S1 = Receptacle 1, Side 1 R2S1 = Receptacle 2, Side 1 R1S2 = Receptacle 1, Side 2 R2S2 = Receptacle 2, Side 2 Notes 1 Number represents the quantity of 1/4-turn ball valves with 3/4-inch hose bibs. 2 Quantity of 20A GFI duplex receptacles. 6 6 6 6 6 6 V1-T6-56 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Power Pedestals Marina Power and Lighting Equipment 6.5 Accessories 6 See Page V1-T6-75. 6 Dimensions Approximate Dimensions in Inches (mm) 6 6 Lighthouse 6 6 6 6 6 6 Top 6 44.00 (1117.6) 6 6 6 6 6 6 6 6 Front View Side View 6 6 6 6 6 6 6 13.75 (249.3) 6 6 Broken View 6 6 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-57 6.5 6 Power Pedestals Marina Power and Lighting Equipment Contents Lighthouse–SS Description 6 Power Pedestals. . . . . . . . . . . . . . . . . . . . . . . . . . . Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lighthouse–SS Available Options. . . . . . . . . . . . . . . . . . . . . . . . Catalog Number Selection . . . . . . . . . . . . . . . . Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . Hatteras Light. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mariner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital Electronic Kilowatthour Meters . . . . . . . . . . Distribution Equipment—Ground Fault Monitor. . . Distribution Equipment—Mega Yacht Powerpoint . Distribution Equipment—Substations . . . . . . . . . . Distribution Equipment—Panels . . . . . . . . . . . . . . Distribution Equipment—Transformers . . . . . . . . . 6 6 6 6 6 6 6 6 6 6 6 6 Lighthouse–SS 6 Product Description 6 6 6 6 The Lighthouse–SS offers the same standard features and available options as the standard Lighthouse. But, like all of the stainless steel products manufactured here, the Lighthouse–SS is made with high-quality 316L stainless steel for superior quality and performance. Features, Benefits and Functions ● ● ● ● 6 Note: 20/125A GFI receptacle. 6 Note: Wireless remote reading of electronic kilowatt meters. ● 6 Note: Clear lens. ● 6 6 6 6 6 6 Note: Meter socket for each side powered (to accept glass style meter). Note: Receptacle configurations available: 30A 30A/30A 30A/50A 50A/50A 100A (single-phase) 120/240V 100A (three-phase) 120/208V 200A (three-phase) 480V ● Photocell controlled 13 watt fluorescent light (clear lens or amber lens for bug reduction) Available with lockable weatherproof doors Hose and cable brackets Long-lasting maintenancefree 316L stainless steel housing with limited lifetime warranty Copper busbar with ratings from 250 to 500A Large removable access panel for easy maintenance and installation Backlit faceplate for easy receptacle plug-in at night 6 6 V1-T6-58 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Page V1-T6-51 V1-T6-54 V1-T6-59 V1-T6-60 V1-T6-61 V1-T6-61 V1-T6-62 V1-T6-65 V1-T6-69 V1-T6-73 V1-T6-79 V1-T6-80 V1-T6-81 V1-T6-82 V1-T6-83 V1-T6-86 V1-T6-89 V1-T6-90 Power Pedestals Marina Power and Lighting Equipment Lighthouse–SS 6.5 Available Options ● 360° controlled 13 watt fluorescent light with amber lens for bug reduction ● Digital electronic metering for each side Note: 20A GFI receptacles are not to be used for shore power. Powder-coated stainless steel weatherproof doors that protect receptacles and breakers ● Lockable doors ● Hose and cable bracket Long-lasting maintenance-free powder-coated stainless steel housing with limited lifetime warranty ● High-speed Internet connection (RJ-45) for each side ● Large removable access panel for easy maintenance and installation ● ● 6 Digital electronic metering (one, two or three element meters available) 20A/125V GFI receptacle (max. of two GFI receptacles per pedestal) 6 6 6 6 High-speed Internet connection Wireless remote metering available for water and electricity Transient voltage surge suppressor (TVSS) to protect from voltage surges, spikes or lightning on the AC power line (extends warranty on internal parts to three years) Single or dual phone and/or cable TV connections Single or dual 3/4-inch hose bibs with stainless steel Handles LED lighting 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Phone and Cable TV Connections 6 New Door 6 6 6 6 6 Copper Busbar with Ratings from 250 to 500A 6 Backlit Faceplate to Aid in Hooking Up at Night 6 6 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-59 6.5 Marina Power and Lighting Equipment Catalog Number Selection L D U 4 7 0 0 0 0 0 0 1 2 K M 6 6 Type L = Lighthouse S = LHSS 6 6 6 6 6 Metering Type U = Unmetered D = Digital electronic meters (side one) T = Digital electronic meters (side two) B = Digital electronic meters (both sides) R = Receptacles metered individually M = One meter socket (100A) N = Two meter socket (100A each) V = 200A meter socket 6 6 6 6 6 6 6 6 6 6 0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8 0 0 0 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 8 8 8 = None = 20A GFI duplex = 30A, 125V = 50A, 125V = 50A, 125/250V = 100A, 208V = 100A, 250V = 100A, 277/480V = 100A, 480V R4S2 6 R3S2 6 Sides and Receptacles R2S2 6 R1S2 6 Lighting and Lens Color = 7W light Amber = Dual 7W light Amber = 9W light Amber = 13W light Amber = Dual 13W light Amber = No lighting Amber = 7W light Clear = Dual 7W light Clear = 9W light Clear = 13W light Clear = Dual 13W light Clear = No lighting Clear = 7W light Special = Dual 7W light Special = 9W light Special = 13W light Special = Dual 13W light Special = No lighting Special = 350 MA LED Amber = 700 MA LED Amber = 350 MA LED Clear = 700 MA LED Clear = 350 MA LED Special = 700 MA LED Special R4S1 A B C D E F G H I J K L M N O P Q R S T U V W Y R2S1 6 R1S1 6 R3S1 6 Power Pedestals 0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 Water Option 1 =0 =1 =2 = Single water meter = Dual water meter = Single meter, 2V = 1 frost free = 2 frost free Extra Unmetered GFI Receptacles 2 0 = None 1 =1 2 =2 Phone Cable TV and Internet Options Phone Cable TV Internet Jack Jack Option A = 1 0 0 B = 1 0 1 C = 1 0 2 D = 1 1 0 E = 1 1 1 F = 1 1 2 G = 1 2 0 H = 1 2 1 I = 1 2 2 J = 2 0 0 K = 2 0 1 L = 2 0 2 M= 2 1 0 N = 2 1 1 O = 2 1 2 P = 2 2 0 Q = 2 2 1 R = 2 2 2 S = 0 2 2 T = 0 0 1 U = 0 0 2 V = 0 1 0 W= 0 1 1 X = 0 1 2 Y = 0 2 0 Z = 0 2 1 0 = 0 0 0 Bus S = Single-phase 3/8-inch copper busbar F = Three-phase 3/8-inch copper busbar C = Single-phase 3/8-inch Canadian busbar T = Three-phase 3/8-inch Canadian busbar M = Single-phase 300 kcmil mechanical lug bus Z = Three-phase 300 kcmil mechanical lug bus L = Single-phase 350 kcmil mechanical lug bus P = Three-phase 350 kcmil mechanical lug bus N = Single-phase 1/4-inch copper busbar Q = Single-phase 1/4-inch split mechanical busbar Receptacle: R1S1 = Receptacle 1, Side 1 R2S1 = Receptacle 2, Side 1 R1S2 = Receptacle 1, Side 2 R2S2 = Receptacle 2, Side 2 Notes 1 Number represents the quantity of 1/4-turn ball valves with 3/4-inch hose bibs. 2 Quantity of 20A GFI duplex receptacles. 6 6 6 6 6 6 V1-T6-60 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Power Pedestals Marina Power and Lighting Equipment 6.5 Accessories 6 See Page V1-T6-75. 6 Dimensions Approximate Dimensions in Inches (mm) 6 6 Lighthouse–SS 6 6 6 6 6 6 6 6 6 6 40.00 (1016.0) 6 6 6 6 6 6 6 6 6 6 9.88 (251.0) 6 6 6 6 6 6 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-61 6.5 6 Power Pedestals Marina Power and Lighting Equipment Contents Admiral–SS Description 6 Power Pedestals. . . . . . . . . . . . . . . . . . . . . . . . . . . Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . Admiral–SS Catalog Number Selection . . . . . . . . . . . . . . . . Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . Hatteras Light. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mariner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital Electronic Kilowatthour Meters . . . . . . . . . . Distribution Equipment—Ground Fault Monitor. . . Distribution Equipment—Mega Yacht Powerpoint . Distribution Equipment—Substations . . . . . . . . . . Distribution Equipment—Panels . . . . . . . . . . . . . . Distribution Equipment—Transformers . . . . . . . . . 6 6 6 6 6 6 6 6 6 6 6 6 Admiral–SS 6 Product Description Features Truly the flagship of our unitized pedestal line, the Admiral–SS possesses amperage capabilities up to 500A and voltages of 480/277 three-phase, 120/240 singlephase and combinations of these receptacles all in one unit to serve nearly any size Mega Yacht. ● 6 6 6 6 6 ● Heavy 316L stainless steel housing that is powder coated with a polyester resin Photocell controlled 13 watt fluorescent light with clear lens that provides 360 degrees of lighting Available Options ● ● ● ● 6 6 ● 6 Dual phone and/or cable TV connections Four 100A receptacles of any two voltage combinations such as 277/480 three-phase, 120/208 three-phase or 120/240 single-phase 200A/480V receptacles when the 100A 120/240V receptacles are used, two 50A 120/240V receptacles can also be provided for a total of 500A 20A/125V GFI receptacle (max. of two GFI receptacles per pedestal) Note: 20A GFI receptacles are not to be used for shore power. 6 ● 6 6 ● 6 6 ● ● 6 ● 6 V1-T6-62 Single or dual Cat5 high-speed Internet connections Single or dual water 1/4-turn ball valves with 3/4-inch hose bibs and stainless steel handles Digital metering available Wireless remote metering available for water and electricity LED lighting Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Page V1-T6-51 V1-T6-54 V1-T6-58 V1-T6-63 V1-T6-64 V1-T6-64 V1-T6-65 V1-T6-69 V1-T6-73 V1-T6-79 V1-T6-80 V1-T6-81 V1-T6-82 V1-T6-83 V1-T6-86 V1-T6-89 V1-T6-90 Power Pedestals Marina Power and Lighting Equipment 6.5 Catalog Number Selection 6 A D U 4 7 0 0 0 0 0 0 1 2 K M Type A = Admiral–SS Lighting and Lens Color A = 7W light Amber B = Dual 7W light Amber C = 9W light Amber D = 13W light Amber E = Dual 13W light Amber F = No lighting Amber G = 7W light Clear H = Dual 7W light Clear I = 9W light Clear J = 13W light Clear K = Dual 13W light Clear L = No lighting Clear M = 7W light Special N = Dual 7W light Special O = 9W light Special P = 13W light Special Q = Dual 13W light Special R = No lighting Special S = 350 MA LED Amber T = 700 MA LED Amber U = 350 MA LED Clear V = 700 MA LED Clear W = 350 MA LED Special Y = 700 MA LED Special R3S2 R4S2 0 0 0 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 8 8 8 None 20A GFI duplex 30A, 125V 50A, 125V 50A, 125/250V 100A, 208V 100A, 250V 100A, 277/480V 100A, 480V R2S2 0 1 2 3 4 5 6 7 8 0 = 1 = 2 = 3 = 4 = 5 = 6 = 7 = 8 = R1S2 R4S1 R3S1 R2S1 Metering Type U = Unmetered D = Digital electronic meters (side one) T = Digital electronic meters (side two) B = Digital electronic meters (both sides) M = One meter socket (100A) N = Two meter socket (100A each) V = 200A meter socket R1S1 Sides and Receptacles 0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 Water Option 1 =0 =1 =2 = Single water meter = Dual water meter = Single meter, 2V Extra Unmetered GFI Receptacles 0 = None 1 =1 2 =2 6 6 Phone Cable TV and Internet Options Phone Cable TV Internet Jack Jack Option 2 A = 1 0 0 B = 1 0 1 C = 1 0 2 D = 1 1 0 E = 1 1 1 F = 1 1 2 G = 1 2 0 H = 1 2 1 I = 1 2 2 J = 2 0 0 K = 2 0 1 L = 2 0 2 M = 2 1 0 N = 2 1 1 O = 2 1 2 P = 2 2 0 Q = 2 2 1 R = 2 2 2 S = 0 2 2 T = 0 0 1 U = 0 0 2 V = 0 1 0 W= 0 1 1 X = 0 1 2 Y = 0 2 0 Z = 0 2 1 0 = 0 0 0 6 6 6 6 6 6 6 6 6 6 6 Bus S = Single-phase 3/8-inch copper busbar F = Three-phase 3/8-inch copper busbar C = Single-phase 3/8-inch Canadian busbar T = Three-phase 3/8-inch Canadian busbar M = Single-phase 300 kcmil mechanical lug bus Z = Three-phase 300 kcmil mechanical lug bus L = Single-phase 350 kcmil mechanical lug bus P = Three-phase 350 kcmil mechanical lug bus N = Single-phase 1/4-inch copper busbar Q = Single-phase 1/4-inch split mechanical busbar D = Dual-phase busbar 6 6 6 6 6 6 Receptacles: R1S1 = Receptacle 1, Side 1 R2S1 = Receptacle 2, Side 1 R3S1 = Receptacle 3, Side 1 R4S1 = Receptacle 3, Side 1 R1S2 = Receptacle 1, Side 2 R2S2 = Receptacle 2, Side 2 R3S2 = Receptacle 3, Side 2 R4S2 = Receptacle 3, Side 2 6 6 6 6 Notes 1 Number represents the quantity of 1/4-turn ball valves with 3/4-inch hose bibs. 2 Number represents the quantity of RJ-45 high-speed Internet jacks. 6 Internet option also available. Contact factory for details. 6 6 6 6 6 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-63 6.5 6 6 Power Pedestals Marina Power and Lighting Equipment Accessories See Page V1-T6-75. Dimensions 6 Approximate Dimensions in Inches (mm) 6 Admiral–SS Front 6 Side One Back Side Two 6 6 6 6 6 50.54 (1283.8) 6 6 6 6 6 6 6 6 6 2.00 (50.8) Water Access 6 6 6 14.00 (355.6) 6 6 240V Electrical Access CATV/INT. Access 6 6 0.75 (19.1) 6 280V Electrical Access 10.00 (254.0) CATV/INT. Access 12.50 (317.5) Ø 0.62 (Ø 15.9) 14.00 (355.6) 6 Base Footprint 6 6 V1-T6-64 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Power Pedestals Marina Power and Lighting Equipment 6.5 Contents Newport Harbor Mate Description Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Newport Harbor Mate Available Options . . . . . . . . . . . . . . . . . . . . . . . Catalog Number Selection . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Hatteras Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mariner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital Electronic Kilowatthour Meters . . . . . . . . . Distribution Equipment—Ground Fault Monitor . . Distribution Equipment—Mega Yacht Powerpoint Distribution Equipment—Substations . . . . . . . . . . Distribution Equipment—Panels . . . . . . . . . . . . . . Distribution Equipment—Transformers . . . . . . . . . Page V1-T6-51 V1-T6-54 V1-T6-58 V1-T6-62 V1-T6-66 V1-T6-67 V1-T6-68 V1-T6-68 V1-T6-69 V1-T6-73 V1-T6-79 V1-T6-80 V1-T6-81 V1-T6-82 V1-T6-83 V1-T6-86 V1-T6-89 V1-T6-90 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Newport Harbor Mate Product Description Five years of development and 30 prototype models have yielded this unit the most innovative mini-power center available. Host to a variety of electrical services, contained in a compact yet strong housing, the Newport Harbor Mate is packed with features. 6 Features, Benefits and Functions ● ● ● ● 6 Tough and durable resin housing with UV inhibitor for lasting finish Photocell controlled 7 and 9 watt fluorescent light (clear lens or amber lens for bug reduction) Designed to mount on a dock box, piling or stainless steel stand Copper busbar with a maximum rating of 140A 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-65 6.5 6 6 6 6 6 Power Pedestals Marina Power and Lighting Equipment Newport Harbor Mate (Shown with Optional Stand) ● Tough and durable resin housing with UV inhibitor for lasting finish 6 Photocell controlled 7 watt fluorescent light with amber lens for bug reduction 6 6 6 Available with single, dual or combination of 30A or 50A receptacles 20A/125V GFI receptacle (max. of two GFI receptacles per pedestal) Note: 20A GFI receptacles are not to be used for shore power. ● 6 6 ● Available with single, dual or combo of 30 or 50A receptacles 20A/125V GFI receptacle Phone, cable TV, high-speed Internet connections Digital electronic meter Lockable weatherproof door that protects receptacles and breakers 6 Available Options ● ● ● Single or dual phone, cable TV, high-speed Internet connections Electronic metering (one or two element meters available) 316L stainless steel stand LED lighting Single or dual 1/2-turn brass ball valve with 3/4-inch hose bibs Stainless steel stand Designed to mount on a dock box, piling, wall or optional stand (shown in photo) 6 6 6 6 6 6 6 6 Mounting Option Backlit Faceplate 6 6 6 6 6 6 6 6 6 6 V1-T6-66 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Power Pedestals Marina Power and Lighting Equipment 6.5 Catalog Number Selection 6 N A Y B U 4 3 0 1 1 2 W M Type N = NP Harbor Mate C = NP Camp Mate Lighting and Lens Color A = 7W light Amber C = 9W light Amber F = No lighting Amber G = 7W light Clear I = 9W light Clear L = No lighting Clear M = 7W light Special O = 9W light Special R = No lighting Special S = 350 MA LED Amber T = 700 MA LED Amber U = 350 MA LED Clear V = 700 MA LED Clear W = 350 MA LED Special Y = 700 MA LED Special Photocell Y = Yes N = No Lighting Protection B = Breaker protected F = Fuse protected Metering Type 1 U = Unmetered D = Digital electronic meters R = Receptacles metered individually Sides and Receptacles R1S1 R2S1 R3S1 0 0 0 1 1 1 2 2 3 3 4 4 0 = None 1 = 20A GFI duplex 2 = 30A, 125V 3 = 50A, 125V 4 = 50A, 125/250V Stand 0 =0 1 =1 6 Bus S = Single-phase 1/4-inch copper busbar F = Three-phase 1/4-inch copper busbar C = Single-phase 1/4-inch Canadian busbar M = Mechanical lug 2/0 Q = Single-phase 1/4-inch split mechanical busbar (with stand ONLY) A = 1/4-inch Canadian mechanical Water Option 2 0 =0 1 =1 2 =2 6 6 6 6 6 6 6 Hard Wired Breakers S1 0 = None 2 = 20A, two-pole 3 = 30A 6 6 6 Phone Cable TV and Internet Options Phone Jack Cable TV Jack Internet Option A = 1 0 0 B = 1 0 1 C = 1 0 2 D = 1 1 0 E = 1 1 1 (Camp Mate only) T = 0 0 1 V = 0 1 0 W= 0 1 1 0 = 0 0 0 6 6 6 6 Receptacles: R1 = Receptacle 1 R2 = Receptacle 2 6 Notes 1 20A GFIs not metered. 2 Number represents the quantity of 1/4-turn ball valves with 3/4-inch hose bibs (with stand only). 6 6 6 6 6 6 6 6 6 6 6 6 6 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-67 6.5 6 6 Power Pedestals Marina Power and Lighting Equipment Accessories See Page V1-T6-75. Dimensions 6 Approximate Dimensions in Inches (mm) 6 Newport Harbor Mate 6 0.12 (3.2) 0.12 (3.2) 9.18 (233.0) 9.18 (233.0) 6 6 10.38 (263.7) 10.38 (263.7) 6 6 6 7.44 (189.1) 10.52 (267.2) 7.44 (189.1) 10.52 (267.2) 6 15.28 (388.0) 6 6 14.53 (369.0) 14.53 (369.0) 13.63 (346.2) 12.88 (327.2) 6 6 6 4º 4º 6 10.38 (263.7) 10.38 (263.7) 9.59 (243.6) 6 6 6 6 6 1.54 (39.1) 4.02 (102.2) 2.37 (60.3) 1.68 (42.7) 6 1.68 (42.7) 3.40 (86.4) 6.70 (170.2) Newport Redesign 1.54 (39.1) 4.02 (102.2) 2.37 (60.3) 3.40 (86.4) 6.70 (170.2) Newport Redesign With Meters 6 6 6 6 6 6 6 V1-T6-68 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Power Pedestals Marina Power and Lighting Equipment 6.5 Contents Hatteras Light Description Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . Hatteras Light Available Options . . . . . . . . . . . . . . . . . . . . . . . Catalog Number Selection . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mariner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital Electronic Kilowatthour Meters . . . . . . . . . Distribution Equipment—Ground Fault Monitor . . Distribution Equipment—Mega Yacht Powerpoint Distribution Equipment—Substations . . . . . . . . . . Distribution Equipment—Panels . . . . . . . . . . . . . . Distribution Equipment—Transformers . . . . . . . . . Page V1-T6-51 V1-T6-54 V1-T6-58 V1-T6-62 V1-T6-65 V1-T6-70 V1-T6-71 V1-T6-72 V1-T6-72 V1-T6-73 V1-T6-79 V1-T6-80 V1-T6-81 V1-T6-82 V1-T6-83 V1-T6-86 V1-T6-89 V1-T6-90 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Hatteras Light Product Description The Hatteras® Light is an elegant and low cost alternative to the Lighthouse. It uses the same 360 degree light assembly as the Lighthouse, yet is only 30 inches tall. Thousands of these attractive pedestals are found not only in marinas, but also around pools, deck areas, boardwalks and landscape areas. The housing will never rust or corrode and comes with a limited lifetime warranty. This unit is popular for smaller slips at marinas with the Lighthouse and for private docks. 6 Features, Benefits and Functions ● ● ● ● 6 Photocell controlled 13 watt fluorescent light (clear lens or amber lens for bug reduction) Circuit breakers Heavy resin housing with a two-part polyurethane coating for a UV resistant, long-lasting finish Copper busbar with a maximum rating of 140A 6 6 6 6 6 6 6 Note: Wireless remote reading of electronic kilowatt meters. 6 Note: Clear lens. 6 Note: Custom paint color. 6 6 6 6 6 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-69 6.5 6 Power Pedestals Marina Power and Lighting Equipment Available Options Hatteras Light 360° controlled 13 watt fluorescent light with amber lens for bug reduction 6 6 Receptacle configurations available: Side 1: 30A, 50A Side 2: 30A, N/A Note: Custom configurations also available 6 6 ● Note: 20A GFI receptacles are not to be used for shore power. ● ● Digital electronic metering 6 6 ● Circuit breakers 6 Phone, cable TV, high-speed Internet connections 6 6 20A/125V GFI receptacle (max. of two GFI receptacles per pedestal) ● Digital electronic metering (one or two element meter available) Single or dual phone, cable TV, high-speed Internet connections Single or dual 1/2-inch or 3/4-inch silcock with stainless steel handles LED lighting 1/4-inch resin housing with a two-part polyurethane coating for a UV resistant, long-lasting finish 6 6 1/2-turn brass ball valve and 3/4-inch hose bib 6 6 6 6 6 6 6 6 Copper Busbar with Ratings up to 140A 20A/125A GFI Receptacle 6 6 6 6 6 6 Faceplate 6 6 6 6 V1-T6-70 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Power Pedestals Marina Power and Lighting Equipment 6.5 Catalog Number Selection 6 H D Y B D 4 7 0 1 2 A M Type H = Hatteras Light R = Park Light A B C D E F G H I J K L M N O P Q R S T U V W Y Lighting and Lens Color = 7W light Amber = Dual 7W light Amber = 9W light Amber = 13W light Amber = Dual 13W light Amber = No lighting Amber = 7W light Clear = Dual 7W light Clear = 9W light Clear = 13W light Clear = Dual 13W light Clear = No lighting Clear = 7W light Special = Dual 7W light Special = 9W light Special = 13W light Special = Dual 13W light Special = No lighting Special = 350 MA LED Amber = 700 MA LED Amber = 350 MA LED Clear = 700 MA LED Clear = 350 MA LED Special = 700 MA LED Special 6 Bus S = Single-phase 1/4-inch copper busbar F = Three-phase 1/4-inch copper busbar C = Single-phase 1/4-inch Canadian busbar M = Mechanical lug 2/0 3 A = 1/4-inch Canadian mechanical Photocell Y = Yes N = No Lighting Protection B = Breaker protected F = Fuse protected Metering Type 1 U = Unmetered D = Digital electronic meters R = Receptacles metered individually Sides and Receptacles R1S1 R2S1 R1S2 0 0 0 1 1 1 2 2 2 3 3 3 4 4 4 0 = None 1 = 20A GFI duplex 2 = 30A, 125V 3 = 50A, 125V 4 = 50A, 125/250V Water Option 2 0 =0 1 = 1 (1/2-inch) 2 = 2 (1/2-inch) 3 = 1 (3/4-inch) 4 = 2 (3/4-inch) Hard Wired Breakers S1 0 = None 2 = 20A, two-pole 3 = 30A 6 6 6 6 Phone Cable TV and Internet Options Phone Cable TV Internet Jack Jack Option A= 1 0 0 B= 1 0 1 C = 1 0 2 D= 1 1 0 E = 1 1 1 F = 1 1 2 G= 1 2 0 H= 1 2 1 I = 1 2 2 J = 2 0 0 M= 2 1 0 P = 2 2 0 S = 0 2 2 T = 0 0 1 U= 0 0 2 V = 0 1 0 W= 0 1 1 X = 0 1 2 Y = 0 2 0 Z = 0 2 1 6 6 6 6 6 6 6 6 6 Receptacles: R1 = Receptacle 1 R2 = Receptacle 2 6 Notes 1 20A GFIs not metered. 2 Number represents the quantity of 1/4-turn ball valves with 3/4-inch hose bibs. 3 Wire size #2/0 kcmil or less. 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-71 6.5 6 6 Power Pedestals Marina Power and Lighting Equipment Accessories See Page V1-T6-75. Dimensions 6 Approximate Dimensions in Inches (mm) 6 Hatteras 6 6 6 6 6 6 Busbar Access Top Removed 6 Inside Top 6 13.39 (340.2) 6 6 6 6 6 6 6 6 30.98 (786.9) 6 6 6 6 6 6 6 6 6 6 V1-T6-72 7.90 (200.7) 7.90 (200.7) Side View Front View Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Power Pedestals Marina Power and Lighting Equipment 6.5 Contents Firehouse Description Page Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . Lighthouse. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . Hatteras Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . Firehouse Available Options . . . . . . . . . . . . . . . . . . . . . . . Catalog Number Selection . . . . . . . . . . . . . . . . Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mariner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital Electronic Kilowatthour Meters . . . . . . . . . Distribution Equipment—Ground Fault Monitor . . Distribution Equipment—Mega Yacht Powerpoint Distribution Equipment—Substations . . . . . . . . . . Distribution Equipment—Panels . . . . . . . . . . . . . . Distribution Equipment—Transformers . . . . . . . . . V1-T6-51 V1-T6-54 V1-T6-58 V1-T6-62 V1-T6-65 V1-T6-69 V1-T6-74 V1-T6-74 V1-T6-75 V1-T6-78 V1-T6-79 V1-T6-80 V1-T6-81 V1-T6-82 V1-T6-83 V1-T6-86 V1-T6-89 V1-T6-90 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Firehouse Product Description Created as a complete solution for fire and rescue needs, this pedestal features fire extinguisher storage and a mounted alarm strobe light and siren, as well as an optional life ring. This unit is well equipped for any marina emergency. The alarm strobe light and siren can be automatically activated when the door is open or optional life ring is removed. Features, Benefits and Functions ● ● ● ● ● 6 Firehouse Alarm strobe light and siren: automatically activated when door is open or optional life ring is removed Photocell controlled 13 watt fluorescent light (clear lens or amber lens for bug reduction) 10 lb ABC Type fire extinguisher 316L stainless steel polyester powder-coated housing Polycarbonate top assembly 6 High-visibility alarm strobe light and warning siren 6 Photocell controlled energy efficient 13 watt fluorescent light with amber lens for bug reduction 6 6 Stainless steel housing with oven-baked enamel finish with a polycarbonate base and top 6 Remote control unit can automatically call select services via a four channel transmitter: Medical emergency Fire emergency Police emergency Optional general emergency 6 6 6 6 6 6 6 6 6 6 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-73 6.5 6 6 6 Power Pedestals Marina Power and Lighting Equipment Available Options ● ● 24-inch life ring 20 lb ABC Type fire extinguisher available Catalog Number Selection 6 F A Y A E N 6 24-Inch Life Ring R = Include life ring N = No life ring Type F = Firehouse 6 Photocell Y = Yes N = No 6 Alarm/Strobe A = Include alarm/strobe N = No alarm/strobe 6 6 A B C D E F G H 6 6 6 = 7W light = Dual 7W light = 9W light = 13W light = Dual 13W light = No lighting = 7W light = Dual 7W light Amber Amber Amber Amber Amber Amber Clear Clear Fire Extinguisher E = Include 10 lb extinguisher N = No extinguisher X = Include 20 lb extinguisher Lighting and Lens Color I = 9W light Clear J = 13W light Clear K = Dual 13W light Clear L = No lighting Clear M = 7W light Special N = Dual 7W light Special O = 9W light Special P = 13W light Special Q = Dual 13W light R = No lighting S = 350 MA LED T = 700 MA LED U = 350 MA LED V = 700 MA LED W = 350 MA LED Y = 700 MA LED 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 V1-T6-74 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Special Special Amber Amber Clear Clear Special Special 6.5 Power Pedestals Marina Power and Lighting Equipment Accessories 6 Accessories for Custom Design Marina Products, Resin and Stainless Steel Pedestals and Power Products Replacement Parts Catalog Numbers Catalog Number Description 6 Replacement Parts Catalog Numbers, continued Receptacles 20A GFCI duplex MPL3038 30A 125V twistlock MPL3039 50A 125V twistlock MPL3040 50A 125/250V twistlock MPL3045 100A 120/240V pin and sleeve MPL4100R12W 100A 120/208V pin and sleeve MPL5100R9W 100A 480V four-wire pin and sleeve MPL4100R7W Description 6 Lighthouse, Lighthouse–SS, Powerhouse, Powerhouse–SS, Hatteras, Park Light, continued 20A GFCI receptacle external cover set MPL1101 30A receptacle external cover set MPL1102 50A receptacle external cover set MPL1105 Single-pole external breaker cover set MPL11061 Two-pole external breaker cover set MPL11062 Three-pole external breaker cover set MPL11063 100 A 480V five-wire pin and sleeve MPL5100R7W Lighthouse, Lighthouse–SS, Powerhouse, Powerhouse–SS 200A 277/480V pin and sleeve (Russellstoll®) MPL4200R7W Lighthouse/Powerhouse pedestal main housing MPL6006 30A 125V RV RV3042 Lighthouse–SS/Powerhouse–SS pedestal main housing MPL6006S 50A 125/250V RV RV3043 Lighthouse/Powerhouse main door MPL6007 Circuit Breakers 6 Catalog Number 6 6 6 6 6 6 6 Lighthouse–SS/Powerhouse–SS main door MPL6007S 20A 125V single-pole QCF1020 Lighthouse/Powerhouse spring closure MPL1099 20A 125V single-pole GFCI QCGF1020 Lighthouse Powerhouse top isolation plate MPL6012 30A 125V single-pole QCF1030 Lighthouse/Lighthouse–SS breaker plate MPL1141 30A 125V single-pole GFCI QCGF1030 Powerhouse/Powerhouse–SS breaker plate RV1112 50A 125V single-pole QCF1050 QCF2020 Lighthouse/Lighthouse–SS/Powerhouse/ Powerhouse–SS Hose and cable brackets MPL1087 20A 125/250V two-pole 6 20A 125/250V two-pole GFCI QCGF2020 Lighthouse/Powerhouse stainless steel hinge MPL1088 6 30A 125/250V two-pole QCF2030 Lighthouse/Powerhouse complete pedestal base with busbar assembly MPL6004A 30A 125/250V two-pole GFCI QCGF2030 MPL6004FA 50A 125/250V two-pole QCF2050 Lighthouse/Powerhouse complete pedestal base with three-phase busbar assembly 50A 125/250V two-pole GFCI QCGF2050 Lighthouse/Powerhouse pedestal base without busbars MPL6004 60A 125/250V two-pole QCF2060 Lighthouse/Powerhouse aluminum blank access panel MPL5500 100A 125/250V two-pole GHC2100D MPL1140A 100A 120/208V three-pole GHC3100D Lighthouse/Lighthouse–SS/Powerhouse/ Powerhouse–SS complete busbar assembly 6 Lighthouse/Lighthouse–SS/Powerhouse/Powerhouse–SS complete three-phase busbar assembly MPL1140FA Copper busbar with nuts and washers MPL3471 6 20A GFCI—00 amber resin faceplate MPL1120 30A—20 GFCI amber resin faceplate MPL1121 30–50A amber resin faceplate MPL1122 30–30A amber resin faceplate MPL1127 30–00A amber resin faceplate MPL1129 50–50A amber resin faceplate MPL1123 50A—20 GFCI amber resin faceplate MPL1124 20 GFCI—20 GFCI amber resin faceplate MPL1125 00–00 amber resin faceplate MPL1126 50A—00 amber resin faceplate MPL1128 100A faceplate MPL1142 200A 277/480V three-pole JT2200FA Fluorescent Light Assembly 13 watt 120V 60 Hz ballast MPL2400 7 watt 120V 60 Hz ballast MPL2401 13 watt socket MPL3079 7 watt socket MPL3077 13 watt fluorescent bulb MPL3018 7 watt fluorescent bulb MPL3019 Photocell MPL3044 Photocell nuts MPL3034 Lighthouse in-line fuse MPL3026 Lighthouse in-line fuse holder MPL3027 Lighthouse, Lighthouse–SS, Powerhouse, Powerhouse–SS, Hatteras, Park Light Top with complete light and lens assembly MPL6003A 20A GFCI—00 amber resin faceplate assembly with breakers MPL1120A Top with complete light and lens assembly—fused MPL6003FA 30A—20 GFCI amber resin faceplate assembly with breakers MPL1121A Top only MPL6003 30–50A amber resin faceplate assembly with breakers MPL1122A Amber lens MPL6005 Clear lens MPL6008 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 V1-T6-75 6.5 Power Pedestals Marina Power and Lighting Equipment 6 Replacement Parts Catalog Numbers, continued 6 Description 6 Catalog Number Lighthouse, Lighthouse–SS, Powerhouse, Powerhouse–SS, continued MPL1127A 50–50A amber resin faceplate assembly with breakers MPL1123A 50A—20 GFCI amber resin faceplate assembly with breakers MPL1124A 20 GFCI—20 GFCI amber resin faceplate assembly with breakers MPL1125A 50A—00 amber resin faceplate assembly with breakers MPL1128A 30–00A faceplate assembly with breakers MPL1129A 6 100A faceplate assembly with breakers MPL1142A Powerhouse 30–50 receptacle plate RV1143 6 Powerhouse (30A—00) receptacle plate RV11433 Powerhouse (50A—00) receptacle plate RV11435 6 Powerhouse breaker plate RV1112 6 6 Description Catalog Number Digital Electronic Meters 30–30A amber resin faceplate assembly with breakers 6 Replacement Parts Catalog Numbers, continued Single element, 14-pin quick disconnect (no CTs) MPL17A1 Single element, 14-pin quick disconnect (with CTs) MPL17A2 1 Single element, 14-pin quick disconnect (with CTs) MPL17A2 2 Dual element, 14-pin quick disconnect (no CTs) MPL17B1 Dual element, 14-pin quick disconnect (with CTs) MPL17B2 1 Dual element, 14-pin quick disconnect (with CTs) MPL17B2 2 Three element, 14-pin quick disconnect (no CTs) MPL17C1 Three element, 14-pin quick disconnect (with CTs) MPL17C2 1 Three element, 14-pin quick disconnect (with CTs) MPL17C2 2 Single element coil transformers (CTs) MPL30321 1 Single element coil transformers (CTs) MPL30321 2 Dual element coil transformers (CTs) MPL30322 1 Dual element coil transformers (CTs) MPL30322 2 Three element coil transformers (CTs) MPL30323 1 Three element coil transformers (CTs) MPL30323 2 6 Phone, Cable, Internet Assemblies Lighthouse/Powerhouse complete phone and cable assembly MPL1114/RV1114 6 Lighthouse–SS/Powerhouse–SS/Hatteras Light/Park Light complete phone and cable assembly MPL1119/RV1119 6 Hatteras Light/Park Light complete phone and cable assembly MPL1119 Counter (large—old style) MPL3022 Newport Harbor Mate/Camp Mate phone and cable insert assembly MPL1115/RV1115 Counter (small—new style) MPL3021 Lighthouse/Powerhouse access plates with dual Internet jacks MPL5501 Hatteras Light (Marina) and Park Light (RV) 3 Coax cable TV FCF female adpt. with lugnut and washer MPL1086 Pedestal main housing MPL6002 MPL3059 Copper busbar with nuts and washers MPL3468 MPL3037 Complete busbar assembly MPL1108A RV3060 Complete three-phase busbar assembly MPL1108FA 20A GFCI external cover door MPL1101 30A external cover door MPL1102 50A external cover door MPL1105 Light fuse MPL3026 Fuse holder MPL3027 Mounting feet (set of four) MPL7004 6 6 RJ45 CAT5e high-speed internet jack 6 Marine phone receptacle 6 Water Assemblies 6 6 RJ12 CAT3 phone jack Lighthouse/Powerhouse complete water manifold assembly (dual 3/4-inch hose bibs with 1/4-turn ball valves) MPL11A Newport Harbor Mate/Newport Camp Mate water manifold assembly (dual 3/4-inch hose bibs with 1/4-turn ball valves) MPL11C 3/4-inch hose adapter MPL7030 6 Lighthouse/Powerhouse water mounting plate with mounting brackets MPL1132 6 Hatteras Light/Park Light aluminum water mounting plate MPL6584 1/2-inch brass silcock (hose bib) MPL7014 6 3/4-inch stainless steel silcock (hose bib) MPL5271 6 3/4-inch brass ball valve MPL7021 Watts 3/4-inch backflow preventer MPL7015 Notes 1 Lighthouse, Lighthouse–SS, Powerhouse, Powerhouse–SS. 2 Hatteras Light, Park Light, Newport Camp Mate, Newport Harbor Mate. 3 Please contact factory to determine configurations for replacement housing. 6 6 6 6 6 6 6 6 V1-T6-76 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Power Pedestals Marina Power and Lighting Equipment 6.5 Replacement Parts Catalog Numbers, continued Description 6 Catalog Number 6 Newport Harbor Mate (MARINA) and Camp Mate (RV) Amber lens—three-piece MPL1117 Clear lens—three-piece MPL1109 Main housing MPL6000 Main door MPL6001 30–30A faceplate 1 MPL1135 30–50A faceplate 1 MPL1136 50–50A faceplate 1 MPL1137 50A–00 faceplate 1 MPL1138 30A–00 faceplate 1 MPL1139 30–30A faceplate assembly with breakers 1 MPL1135A 30–30–20 GFI faceplate assembly 1 MPL1135G/RV1135G 30–50A faceplate assembly with breakers 1 MPL1136A 30–50–20 GFI faceplate assembly 1 MPL1136G/RV1136G 50–50A faceplate assembly with breakers 1 MPL1137A 50–50–20 GFI faceplate assembly 1 MPL1137G/RV1137G 50A–00 faceplate assembly with breakers 1 MPL1138A 50–20 GFI faceplate assembly 1 MPL1138G/RV1138G 30A–00 faceplate assembly with breakers 1 MPL1139A 30–20 GFI faceplate assembly 1 MPL1139G/RV1139G Mounting brackets MPL7005 36-inch stainless steel stand MPL5506 Copper busbar with nuts and washers MPL3468 Complete busbar assembly MPL1108A Complete three-phase busbar assembly MPL1108FA 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Firehouse (Marina and RV) Red strobe light/siren MPL3020 Firehouse top with lighting assembly and strobe MPLFH6003A Light fuse MPL3029 Fuse holder MPL3028 Door MPL6013 24-inch life ring MPL4201 Life ring bracket MPL4201B Blank access panel MPL6015 Door/life ring switch (pre-2004) MPL3030 Door/life ring switch (new) MPL3050 Door hasp MPL3950 Busbar (double barrel terminal block) MPL3751 10-lb ABC Type fire extinguisher MPL8025 20-lb ABC Type fire extinguisher MPL8025X 6 6 6 6 6 6 6 6 6 Note 1 For custom faceplates to include phone/cable or other accessories, please contact Eaton’s Marina Power & Lighting facility at 1-800-723-8009. 6 6 6 6 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-77 6.5 6 6 6 Power Pedestals Marina Power and Lighting Equipment Dimensions Approximate Dimensions in Inches (mm) Firehouse–SS 6 6 6 6 6 6 6 6 6 6 43.50 (1104.9) 6 6 6 6 6 6 6 6 6 6 6 9.87 (250.6) 6 6 6 6 6 6 V1-T6-78 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 6.5 Power Pedestals Marina Power and Lighting Equipment Contents Smart Start Description Page Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . Hatteras Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Smart Start Mariner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital Electronic Kilowatthour Meters . . . . . . . . . Distribution Equipment—Ground Fault Monitor . . Distribution Equipment—Mega Yacht Powerpoint Distribution Equipment—Substations . . . . . . . . . . Distribution Equipment—Panels . . . . . . . . . . . . . . Distribution Equipment—Transformers . . . . . . . . . V1-T6-51 V1-T6-54 V1-T6-58 V1-T6-62 V1-T6-65 V1-T6-69 V1-T6-73 V1-T6-80 V1-T6-81 V1-T6-82 V1-T6-83 V1-T6-86 V1-T6-89 V1-T6-90 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Smart Start Product Description Features If you have transient boat slips, Eaton Marina Power and Lighting has developed their newest product for your situation. ● The new “Smart Start” pedestal is activated by the swipe of a credit card. A kiosk will be centrally located at the marina and will control up to 32 power pedestals. When a boater wants to use a slip, they will enter the slip number and amount of time they would like and will then be asked to swipe a card in order to activate the pedestal. Once the chosen time is up, the pedestal will shut down. No more free power! ● ● Lighted 316L stainless steel kiosk enclosure Programmable slip time blocks Programmable slip rates printable receipts Standards and Certifications ● UL listing pending Dimensions Approximate Dimensions in Inches (mm) Smart Start Height 60.05 (1525.3) Width 14.15 (359.4) Depth 14.24 (361.9) 6 6 6 6 6 6 6 6 6 6 The “Smart Start” pedestal will not only prevent transient boaters from stealing power, but it will also eliminate the need for 24-hour monitoring of the slips. Boaters will be able to come in at any time of the day and activate a pedestal. 6 6 6 6 6 6 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-79 6.5 6 Power Pedestals Marina Power and Lighting Equipment Contents Marina Power and Lighting Equipment Description 6 6 6 6 6 6 6 6 Page Power Pedestals. . . . . . . . . . . . . . . . . . . . . . . . . . . Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . Hatteras Light. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mariner Digital Electronic Kilowatthour Meters . . . . . . . . . . Distribution Equipment—Ground Fault Monitor. . . Distribution Equipment—Mega Yacht Powerpoint . Distribution Equipment—Substations . . . . . . . . . . Distribution Equipment—Panels . . . . . . . . . . . . . . Distribution Equipment—Transformers . . . . . . . . . Mariner 6 6 6 6 6 Mariner 6 Product Description Features The Mariner is a lighting bollard that can stand from 1.5 to 4 feet tall and can be used in various applications from marina docks, to landscaped areas, golf courses and beyond. The Mariner will have a lifetime warranty on the engineered resin housing that will withstand the harsh marine and land environments from Alaska to the tropics. ● 6 6 6 6 6 6 6 ● ● ● ● Dimensions Can be configured with a 7 watt, 9 watt or 13 watt fluorescent bulb Mounting base and painted pole supplied for desired height Limited lifetime warranty on engineered resin housing Custom colors available Side-mounted option Approximate Dimensions in Inches (mm) Mariner 7 watt 14.15 (359.4) 9 watt/13 watt 14.24 (361.9) Mounting Base and Pole 1.5 feet–4 feet Catalog Number Selection M 5 A R 18 6 6 Type M = Mariner 6 6 Bulb Wattage 5 = 5W 7 = 7W 9 = 9W 3 = 13W 1 = 50 MA LED Color Lens A = Amber C = Clear S = Special Color W = White R = Blue B = Black D = Dark green S = Special Stand Height 18 = 18-inch 24 = 24-inch 36 = 36-inch 48 = 48-inch 6 6 6 6 V1-T6-80 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-51 V1-T6-54 V1-T6-58 V1-T6-62 V1-T6-65 V1-T6-69 V1-T6-73 V1-T6-79 V1-T6-81 V1-T6-82 V1-T6-83 V1-T6-86 V1-T6-89 V1-T6-90 6.5 Power Pedestals Marina Power and Lighting Equipment Contents Digital Electronic Kilowatt Hour Meters Description Page Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . Hatteras Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mariner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital Electronic Kilowatthour Meters Distribution Equipment—Ground Fault Monitor . . Distribution Equipment—Mega Yacht Powerpoint Distribution Equipment—Substations . . . . . . . . . . Distribution Equipment—Panels . . . . . . . . . . . . . . Distribution Equipment—Transformers . . . . . . . . . V1-T6-51 V1-T6-54 V1-T6-58 V1-T6-62 V1-T6-65 V1-T6-69 V1-T6-73 V1-T6-79 V1-T6-80 V1-T6-82 V1-T6-83 V1-T6-86 V1-T6-89 V1-T6-90 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Digital Electronic Kilowatthour Meters Product Description Features Available Options Using the latest surface mount technology, Eaton manufactures a digital electronic kilowatthour meter that exceeds the +/– 2% accuracy required by ANSI (American National Standards Institute) C-12.1 and is approved by the state of California at +/– 1% over the full range of 0–100A from a 0.5–1 power factor and is available for both single- and three-phase applications. Our meter is designed to be user friendly in that all connections from external sources and the meter output are through one 14-pin locking connector. This feature eliminates many common problems, such as reverse line polarity and improper coil polarity. Simple LEDs, both red and green, indicate line and load condition and the pulsed LED indicates the rate of power consumption. ● The meter drives an electromechanical counter that requires a 12V pulse each tenth of a kilowatthour, providing 10 pulses per kilowatt used. The meter output can be hard wired or connected to a transmitter in the pedestal for wireless transmission to a receiver displaying the output on a PC for direct billing of up to 1,000 individual customers. Wireless System All of our meters are “wireless capable” to allow for wireless meter reading. This technology enables the marina or RV park to get meter readings from one central location rather than visiting every site to read the counters. ● ● ● ● 6 Product Selection 200A (SS only) Lockable hasp Ringless (SS only) Five jaw Seven jaw (SS only) 6 6 6 One Element Meter 6 6 6 6 Two Element Meter 6 6 6 Meter Socket Capabilities Meter sockets are available on the Lighthouse and Lighthouse–SS. Standard ● Four jaw ● Ring-type ● 100A 6 6 6 Three Element Meter Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 6 6 V1-T6-81 6.5 6 Power Pedestals Marina Power and Lighting Equipment Contents Ground Fault Monitor Description 6 Power Pedestals. . . . . . . . . . . . . . . . . . . . . . . . . . . Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . Hatteras Light. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mariner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital Electronic Kilowatthour Meters . . . . . . . . . . Distribution Equipment—Ground Fault Monitor Distribution Equipment—Mega Yacht Powerpoint . Distribution Equipment—Substations . . . . . . . . . . Distribution Equipment—Panels . . . . . . . . . . . . . . Distribution Equipment—Transformers . . . . . . . . . 6 6 6 6 6 6 6 6 6 6 6 6 Distribution Equipment—Ground Fault Monitor 6 Product Description Features Our ground fault monitoring systems are designed to detect fault currents in the AC shore power system that are too low to trip a circuit breaker. The ground fault monitor helps reduce the risk of injury or property damage that may result from stray fault currents. Our ground fault monitoring system provides information to the maintenance staff on the overall condition of the AC electrical system. The ground fault monitoring system operates 24 hours a day and can be monitored by nontechnical personnel. ● 6 6 6 6 6 6 6 6 6 6 6 6 ● ● ● Adjustable trip level 10 mA to 10A Current transformers up to 8 1/4-inch diameter Visual and/or audible alarm Housing of fiberglass or powder-coated stainless steel available Standards and Certifications ● UL listed current transformers Power Guard The ground fault monitor detects ground fault currents by means of current transformers (CT), which are placed around main or branch circuits. If a ground fault occurs, the CT will detect the amount of fault current and send a signal to the ground fault monitoring device where the amount of fault current is displayed with the faulty circuit identified. The detected fault can either activate an indicator alarm or disconnect the faulted circuit. 6 6 6 V1-T6-82 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Page V1-T6-51 V1-T6-54 V1-T6-58 V1-T6-62 V1-T6-65 V1-T6-69 V1-T6-73 V1-T6-79 V1-T6-80 V1-T6-81 V1-T6-83 V1-T6-86 V1-T6-89 V1-T6-90 Power Pedestals Marina Power and Lighting Equipment 6.5 Contents Marina Power and Lighting Equipment Description Page Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . Hatteras Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mariner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital Electronic Kilowatthour Meters . . . . . . . . . Distribution Equipment—Ground Fault Monitor . . Distribution Equipment—Mega Yacht Powerpoint Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . Distribution Equipment—Substations . . . . . . . . . . Distribution Equipment—Panels . . . . . . . . . . . . . . Distribution Equipment—Transformers . . . . . . . . . V1-T6-51 V1-T6-54 V1-T6-58 V1-T6-62 V1-T6-65 V1-T6-69 V1-T6-73 V1-T6-79 V1-T6-80 V1-T6-81 V1-T6-82 V1-T6-84 V1-T6-85 V1-T6-86 V1-T6-89 V1-T6-90 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Distribution Equipment—Mega Yacht Powerpoint Product Description Features From the company that is known for its high-quality innovations, Eaton is the only company to offer a selfcontained dual-phase mega yacht unit. Made out of longlasting stainless steel, this mega yacht unit has a copper-wound, low-noise transformer that is double insulated and epoxy overcoated.The mega yacht unit delivers both singlephase and three-phase power to serve most mega yachts. Helping to keep your marina environment tranquil, the mega yacht unit has a low-noise, highly efficient transformer that has isolation mounts to ensure a very quiet operation. ● ● ● ● ● Thermostatically controlled fans in transformer compartment for cooling Heavy stainless steel (316L) cabinet with a polyester powder coating Ventilated sun shields to help unit run cooler in tropical climates Limited lifetime warranty on housing Two or three light 13 watt photocell controlled fluorescent lights on the sun shield for optimal night lighting Available Options ● ● ● ● ● ● ● ● ● ● 200A–480V three-phase receptacles 100% rated breakers Hard wiring busbars for all voltages with breaker protection Two 3/4 inch water outlets with a water meter Two phone, two CATV and two CAT5 high-speed Internet connections Digital electronic meters on all receptacles Primary breaker Two 480V delta or wye 125A three-phase receptacles (IEC) Two 120/208V 100A threephase receptacles (IEC) Two 120/240V 100A singlephase receptacles (IEC) ● ● ● ● ● ● ● ● Up to four 50A 120/240V locking receptacles (NEMA) Up to four 30A 120V locking receptacles (NEMA) Wireless remote metering for electric and water 20A GFI receptacle Primary side 480V maximum 600A Secondary side singlephase 120/240V maximum 100 kVA Secondary side threephase 120/208V maximum 125 kVA Fire extinguisher—10 or 20 lbs 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-83 6.5 Power Pedestals Marina Power and Lighting Equipment 6 Wiring Diagram 6 Powerpoint 6 120/240V Single-Phase Supply 120/240V Three-Phase Supply 1 6 277/480V Supply from Utility 480V 3Ø 3-Pole Main Breaker Dual-Phase Primary Transformer 480V 6 A 6 A 6 O B A 6 6 N B 120/240V 100A 1Ø 2-Pole Breaker 120/240V 100A 1Ø 2-Pole Breaker N N 2 3 B To 480V Service 1 2 3 1 2 3 1 2 3 3 Ø, 277/480V Supply from Main Breaker 3 Ø, 277/480V Supply from Main Breaker 3 Ø, 277/480V Supply from Main Breaker 120/208V 100A 3Ø 3-Pole Breaker 120/208V 100A 3Ø 3-Pole Breaker 120/208V 100A 3Ø 3-Pole Breaker 480V 100A 3Ø 3-Pole Breaker 480V 100A 3Ø 3-Pole Breaker 480V 100A 3Ø 3-Pole Breaker N N CT for Electronic Meter (Typ.) N N N G 6 6 G G G G 100A Hard Wire Buss 120/480V G G 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 6 V1-T6-84 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 200A Hard Wire Buss 277/480V (Ground & Neutral from Utility Supply) Power Pedestals Marina Power and Lighting Equipment 6.5 Dimensions 6 Approximate Dimensions in Inches (mm) 6 Powerpoint Unit 6 6 6 6 6 6 Top With Solar Shield 6 31.00 (787.4) 46.00 (1168.4) 6 6 6 48.54 (1232.9) 6 6 6 6 Left Side Right Side Front 6 6 26.00 (660.4) 6 6 26.00 (660.4) 6 6 Ø 0.50 (Ø 12.7) 6 Base 6 6 6 6 6 6 6 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-85 6.5 6 Power Pedestals Marina Power and Lighting Equipment Contents Substations Description 6 6 6 6 6 6 6 6 Double Panel Substation 6 6 6 Page Power Pedestals. . . . . . . . . . . . . . . . . . . . . . . . . . . Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . Hatteras Light. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mariner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital Electronic Kilowatthour Meters . . . . . . . . . . Distribution Equipment—Ground Fault Monitor. . . Distribution Equipment—Mega Yacht Powerpoint . Distribution Equipment—Substations Features, Benefits and Functions . . . . . . . . . . . Available Options. . . . . . . . . . . . . . . . . . . . . . . . Standards and Certifications . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . Distribution Equipment—Panels . . . . . . . . . . . . . . Distribution Equipment—Transformers . . . . . . . . . 6 6 Distribution Equipment—Substations 6 Product Description Application Description The introduction of substations into the marina and recreational vehicle market allows Eaton to be your complete marina and RV park electrical products supplier. We are able to assist in the design and layout of your marina or RV park electrical system from the primary service provider, to your power pedestal. Our substations are designed for any coastal or inland environment and are constructed of powdercoated stainless steel NEMA 3R housing cabinets. All substation cabinets come with our limited lifetime warranty. All of our substations use Eaton’s panels and circuit breakers providing our customers the utmost in circuit protection and quality. The aluminum and Galvaneal cabinets are recommended for inland applications. The substations can be configured with 50–330 kVA single-phase or three-phase copper wound transformers and up to 20 single-phase or 12 three-phase branch breakers. An optional threesided double-wall cabinet is available that provides air flow between the panels. All substations come standard with temperature controlled cooling fans. 6 6 6 6 6 6 6 6 6 6 6 Product Selection Guide Panel and Transformer Combinations Panel Transformer Single-Phase 200A 50 kVA 300A 75 kVA 400A 100 kVA 600A 150 kVA 700A 167.5 kVA 800A 200 kVA 1000A 250 kVA 1200A 330 kVA Three-Phase 100A 45 kVA 200A 75 kVA 300A 112.5 kVA 400A 150 kVA 600A 225 kVA 800A 300 kVA 6 6 6 6 V1-T6-86 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-51 V1-T6-54 V1-T6-58 V1-T6-62 V1-T6-65 V1-T6-69 V1-T6-73 V1-T6-79 V1-T6-80 V1-T6-81 V1-T6-82 V1-T6-83 V1-T6-87 V1-T6-88 V1-T6-88 V1-T6-88 V1-T6-89 V1-T6-90 Power Pedestals Marina Power and Lighting Equipment 6.5 Features, Benefits and Functions ● ● ● ● Limited lifetime warranty on the housing All stainless steel hardware Temperature controlled cooling fans in the transformer and circuit breaker compartments Lockable door Ventilation The substation ventilation is designed to optimize air circulation over and around the transformers and through the panel compartment so that the substation operates at lower temperatures. Substations come equipped with temperature controlled cooling fans for exhausting hot air from the cabinet and solar shield. 6 6 Substations Temperature-controlled fans for cooling Stainless steel housing with polyester powder coating 6 6 6 6 6 6 Limited lifetime warranty on the housing 6 6 Stainless steel hardware with locking doors 6 6 6 In addition, substations are available with a doublewalled cabinet and solar shield, which allow for cooling of both the exterior surface of the cabinet and the internal components. 6 6 6 6 6 Custom made to your specifications: Single-phase or three-phase copper wound transformers 50 to 330 kVA 6 Up to 1200A main circuit breaker with 20 single-phase or 12 three-phase branch circuit breakers 6 6 Sun Heat 6 6 6 Air Transformers Double-Walled Stainless 6 6 6 6 Cool Air 6 Double-Walled Construction Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 6 V1-T6-87 6.5 6 ● ● 6 6 ● 6 6 6 ● ● 6 ● 6 ● 6 ● 6 6 ● 6 6 6 6 6 Marina Power and Lighting Equipment Available Options 6 6 Power Pedestals ● ● Powder-coated cabinets made of stainless steel or fiberglass Limited lifetime warranty on housing. Transformer and secondary distribution panel in a single enclosure have a one-year limited warranty Stainless steel housing and hardware with locking doors Single-phase and threephase models Overload capacity meets ANSI L57.96–01.250 Optional double-walled construction Temperature controlled fans for cooling Custom-made copper wound single-phase or three-phase transformers from 50–330 kVA Up to 1200A main circuit breaker with 15 singlephase branch circuit breakers or 10 three-phase branch circuit breakers Substations can be equipped with photocells to turn on and off lights A 20A GFI can be installed in the cabinet, as well as a ground fault monitoring system Standards and Certifications ● cULus listed Dimensions Approximate Dimensions in Inches (mm) Substations Standard Substation Height 53.00 (1346.2) Width 51.00 (1295.4) Depth 33.00 (838.2) Side-by-Side Substation Height 53.00 (1346.2) Width 66.00 (1676.4) Depth 30.00 (762.0) Double Panel Substation Height 53.00 (1346.2) Width 63.00 (1600.2) Depth 33.00 (838.2) 6 6 6 6 6 6 6 6 6 6 6 6 V1-T6-88 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Power Pedestals Marina Power and Lighting Equipment 6.5 Contents Panels Description Panel (Stainless Steel Shown) Page Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . Hatteras Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mariner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital Electronic Kilowatthour Meters . . . . . . . . . Distribution Equipment—Ground Fault Monitor . . Distribution Equipment—Mega Yacht Powerpoint Distribution Equipment—Substations . . . . . . . . . . Distribution Equipment—Panels Distribution Equipment—Transformers . . . . . . . . . V1-T6-51 V1-T6-54 V1-T6-58 V1-T6-62 V1-T6-65 V1-T6-69 V1-T6-73 V1-T6-79 V1-T6-80 V1-T6-81 V1-T6-82 V1-T6-83 V1-T6-86 V1-T6-90 6 6 6 6 6 6 6 6 6 6 6 6 6 6 Distribution Equipment—Panels Product Description Features Two of the many products we can offer our customers are Eaton’s PRL-3A and PRL-4 panels as standalone units or in one of our substations. All of our busses are made of copper and are load rated; breakers are bolt-on type. Distribution panels can be 120/240V single-phase, 120/208V threephase, 277/480V three-phase or 220Y/127V three-phase based on your system requirements. Distribution panels can also have a main breaker or a main lug. Branch circuit breakers are provided based on customer requirements. ● ● ● All internal wiring is fine stranded 1000V insulated copper Copper busbars All exterior hardware is stainless steel Available Options ● ● ● ● ● ● NEMA 3R or 4X Powder-coated stainless steel Main breaker up to 1200A Branch breaker 20–1200A Main lug only We also offer 480V models—single-phase and three-phase Standards and Certifications ● ● UL listed cULus listed 6 6 6 6 6 6 Single-Phase ● Up to 1200A main circuit breakers ● Up to 42 branch circuit breakers 6 6 6 Three-Phase ● Up to 1200A main circuit breakers ● Up to 42 branch circuit breakers 6 6 6 6 6 6 6 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T6-89 6.5 6 Power Pedestals Marina Power and Lighting Equipment Contents Transformers Description 6 6 6 6 6 6 6 6 Three-Phase Transformer 6 Page Power Pedestals. . . . . . . . . . . . . . . . . . . . . . . . . . . Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lighthouse–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . Admiral–SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . Hatteras Light. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mariner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital Electronic Kilowatthour Meters . . . . . . . . . . Distribution Equipment—Ground Fault Monitor. . . Distribution Equipment—Mega Yacht Powerpoint . Distribution Equipment—Substations . . . . . . . . . . Distribution Equipment—Panels . . . . . . . . . . . . . . Distribution Equipment—Transformers V1-T6-51 V1-T6-54 V1-T6-58 V1-T6-62 V1-T6-65 V1-T6-69 V1-T6-73 V1-T6-79 V1-T6-80 V1-T6-81 V1-T6-82 V1-T6-83 V1-T6-86 V1-T6-89 6 6 6 6 Distribution Equipment—Transformers 6 Product Description Features Because of the high humidity and corrosive conditions of coastal environments, our transformers are wound with Class H heavily insulated copper bar and are double dipped in tough insulating varnish that protects the copper, as well as reduces the hum that is typical in a transformer that is not double dipped. We provide a second overcoat of high temperature epoxy to protect against the severe saltwater environment. We can provide this transformer in singlephase, from 50–500 kVA, and three-phase, from 45–300 kVA. ● 6 6 6 6 6 6 6 6 6 6 ● ● ● ● Copper wound transformer coils double dipped in high temperature baking varnish All internal wiring is fine stranded 2000V insulated copper Copper busbars Marine transformers with epoxy overcoat All copper-to-copper connections Available Options ● ● ● Single-phase: 50–500 kVA Three-phase: 45–300 kVA Epoxy overcoat for nonmarine applications Primary Voltages ● 480 wye three-phase ● 480V three-phase delta three-wire + ground ● 480V single-phase two-wire + ground Secondary Voltages ● 127/220V three-phase wye four-wire ● 120/208V three-phase wye four-wire ● 120/240V single-phase three-wire Marina Power Distribution Transformer kVA Availabilities ● Single-phase: 50, 75, 100, 150, 167.5, 200, 250, 330, 500 kVA ● Three-phase: 45, 75, 112.5, 150, 225, 300 kVA 6 6 6 6 6 V1-T6-90 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Standards and Certifications ● cULus listed Air Conditioning Disconnects Air Conditioning Disconnects 7.1 Air Conditioning Disconnects Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Application Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Features, Benefits and Functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Standards and Certifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cross-Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T7-2 V1-T7-2 V1-T7-3 V1-T7-3 V1-T7-4 V1-T7-6 V1-T7-7 V1-T7-7 7 7 7 7 7 7 7 Learn Online 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 Volume 1—Residential and Light Commercial CA08100002E—August 2012 www.eaton.com V1-T7-1 7.1 7 Air Conditioning Disconnects Fused, Unfused and Molded Case Switch Contents Air Conditioning Disconnects Description 7 Page Features, Benefits and Functions. . . . . . . . . . . . . . Standards and Certifications . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . . Cross-Reference . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data and Specifications . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 7 7 7 7 7 Complete Line of Fused, Unfused and Molded Case Switch Type Air Conditioning Disconnects 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 Product Description An air conditioning disconnect (ACD) is a disconnect located between a loadcenter (distribution panel) and air conditioner. Eaton’s ACD product line provides an installer or repair personnel with a visible disconnecting means when performing maintenance. ACDs are also known as disconnects, pullouts or air conditioning switches. Non-fused pullout and molded case switch devices provide personnel with a visible ON-OFF disconnecting means. While fused pullout units also perform this function, they also provide an additional level of protection for the air conditioner. Fused and non-fused devices are of a pullout design, where the user physically removes or “pulls out” a tab to break the electrical connection. A molded case switch is similar to a light switch where the user “switches” the unit to the indicated ON-OFF position. Application Description Fused and Non-Fused Pullouts ● ● ● ON/OFF control provided by a pullout handle Pullout handle can be conveniently stored in the compartment in the OFF position, helping to prevent the handle from being misplaced Protective shield cannot be removed until the pullout handle is removed, disconnecting the power Molded Case Switch ● ● ● Rugged molded case construction in a disconnect switch that looks like a circuit breaker but operates like an ordinary household light switch Plug-in molded case switch (included) eliminates the need for pullout handles No need for replacement pullout handles due to loss or theft The most widely used application for ACDs is for residential and light commercial air conditioning units. An ACD is installed outdoors, in visible proximity to the air conditioner condensing unit. ACDs are also found in use with heat pumps, swimming pools, spas, whirlpools and pump houses, and meet 2008 NEC Article 422.31 (B) requirements for servicing electric water heaters. Metallic enclosures are galvanized steel and are installed in various locations. Non-metallic enclosures are a plastic (polycarbonate) enclosure commonly used in coastal or salt-water areas. 7 7 7 7 V1-T7-2 Volume 1—Residential and Light Commercial CA08100002E—August 2012 www.eaton.com V1-T7-3 V1-T7-3 V1-T7-4 V1-T7-6 V1-T7-7 V1-T7-7 Air Conditioning Disconnects Fused, Unfused and Molded Case Switch Features, Benefits and Functions ● ● ● ● ● ● ● ● Single-phase, two-wire, 240 Vac and three-phase, three-wire, 240 Vac NEMA 3R outdoor enclosures offered in metallic and non-metallic versions Easy-to-remove highstrength protective shield for easier wiring and mounting Easy-to-remove front cover (no screws or fasteners to remove) 1-inch knockouts on the bottom, back and side of unit Copper-rated line and load lugs that are easily accessible Ample wiring space for mounting with a stud gun (single keyhole, two- or three-point mounting) Fused devices are service entrance rated ● ● ● ● ● ● ● Horsepower rated (10 hp maximum at 240 Vac) Padlockable door provision for safety and reduction of tampering Metallic enclosures are bottom entry and exit only Non-metallic enclosures have knockouts and a hub provision for top access Non-metallic enclosures have a single unit door and protective shield for installer convenience Non-metallic enclosures are durable and provide excellent resistance to climate changes Factory-installed tamperresistant/weather-resistant receptacles are available as an option on some products 7.1 Standards and Certifications ● 7 7 UL listed File No. E132354, E143893, E196365 7 7 Contact Eaton for details and part numbers for CSA approved units. 7 7 7 7 7 7 7 7 7 Note: Fused non-metallic units require the addition of GB4NM ground bar to obtain a Service Entrance rating. 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 Volume 1—Residential and Light Commercial CA08100002E—August 2012 www.eaton.com V1-T7-3 7.1 7 7 Fused, Unfused and Molded Case Switch Product Selection DPU222R 7 Non-Fused Pullouts Main Ampere Rating 7 Maximum hp Rating 120V 240V Wire Size Range Cu/Al 60ºC or 75ºC — 10 #14–3 DPU222R 1 #14–2 ACD222URNM-A2 1 Catalog Number Catalog Number Galvanized Steel 7 60 Non-Metallic/Polycarbonate Enclosure 7 60 7 7 Air Conditioning Disconnects DPF222R 10 Fused Pullouts Main Ampere Rating 7 — Maximum hp Rating 120V 240V Wire Size Range Cu/Al 60ºC or 75ºC Galvanized Steel 7 30 2 2 3 #14–3 DPF221R 1 7 60 2 3 10 #14–3 DPF222R 1 Non-Metallic 30 2 3 #14–2 ACD221RNM-A2 1 60 3 10 #14–2 ACD222RNM-A2 1 Catalog Number 7 7 7 7 For Service Entrance applications, see footnotes below. DPB222R Molded Case Switch Main Ampere Rating 7 Maximum hp Rating 120V 240V Wire Size Range Cu/Al 60ºC or 75ºC — 10 #14–3 DPB222R 3 #14–2 B60NARNM-A2 3 Galvanized Steel 7 60 Non-Metallic/Polycarbonate Enclosure 7 60 7 — 10 Notes 1 For replacement pullout head, order part number 96-3258-4. 2 To obtain a Service Entrance Rating, the addition of a DPFG (ground bar kit) is required. 3 For replacement molded case switch, order part number BR260NA. 7 7 7 7 7 7 7 7 7 7 7 V1-T7-4 Volume 1—Residential and Light Commercial CA08100002E—August 2012 www.eaton.com Air Conditioning Disconnects Fused, Unfused and Molded Case Switch DPU222RGF20 7.1 ACD with 20 Ampere Ground Fault Receptacle 1 Main Ampere Rating Maximum hp Rating 120V 7 240V Wire Size Range Cu/Al 60ºC or 75ºC Catalog Number 7 Non-Fused Pullouts 60 — 10 #14–3 DPU222RGF20WRTR 2 60 — 10 #14–3 DPU222RGF20 30 2 3 #14–3 DPF221RGF20WRTR 2 30 2 3 #14–3 DPF221RGF20 60 3 10 #14–3 DPF222RGF20WRTR 2 60 3 10 #14–3 DPF222RGF20 7 7 Fused Pullouts DPU222RGF15 7 7 7 7 ACD with 15 Ampere Ground Fault Receptacle 13 Main Ampere Rating Maximum hp Rating 120V 240V Wire Size Range Cu/Al 60ºC or 75ºC Catalog Number 7 7 Non-Fused Pullouts 60 — 10 #14–3 DPU222RGF15 60 — 10 #14–3 DPU222RGF15WRTR 2 30 2 3 #14–3 DPF221RGF15 30 2 3 #14–3 DPF221RGF15WRTR 2 60 3 10 #14–3 DPF222RGF15 60 3 10 #14–3 DPF222RGF15WRTR 2 7 7 Fused Pullouts 7 7 7 Notes 1 Factory-installed GFCI receptacle. 2 Includes weather-resistant/tamper-resistant receptacles to meet 2008 NEC Article 406.8 (A) and 406.11 requirements. 3 NEC permits the maximum receptacle rating of a 15A circuit to be 15A. 7 7 7 7 7 7 7 7 7 7 7 7 7 7 7 Volume 1—Residential and Light Commercial CA08100002E—August 2012 www.eaton.com V1-T7-5 7.1 7 DPU362A 7 7 Air Conditioning Disconnects Fused, Unfused and Molded Case Switch Three-Phase Non-Fused ACD Main Ampere Rating Maximum hp Rating 240V 480V Wire Size Range Cu 75ºC Catalog Number 60 15 30 #14–4 DPU362RA 7 7 7 7 Cross-Reference Cross-Reference 7 7 Catalog Number Description Eaton Square D® GE® Siemens® (Murray®) Milbank Midwest Metallic/Galvanized Steel Enclosure 7 30A fused DPF221R — TF30R WF2030 U3830 U035F2 7 60A fused DPF222R — TF60R WF2060 U3860 U065F1 60A non-fused DPU222R — TFN60R — U3800 U065P010 60A non-fused compact design DPU222R — — WNFC2060 — — 60A molded case switch DPB222R QO200TR TNA60R1 WNAS2060 — U065NA1 7 60A non-fused with ground fault receptacle DPU222RGF — TFN60RGFR WN2060GFCI U3822-20GR U065P010 7 30A fused with ground fault receptacle DPF221RGF — — WF2030GFCI — U035F010 60A fused with ground fault receptacle DPF222RGF — — WF2060GFCI — U065F010 60A non-fused with 1/2-inch wire harness DPU222R12W — — — — — 60A non-fused with 3/4-inch wire harness DPU222R34W — — — — — 60A three-phase 600V molded case switch DPU362RA — — — — U0653F 7 7 7 7 Non-Metallic/Polycarbonate Enclosure 30A fused ACD221RNM-A2 TPF30R WF2030PL — P035F 60A fused ACD222RNM-A2 TPF60R WF2060PL — P065F 60A non-fused ACD222URNM-A2 TPN60R1 WN2060PL — P065P1 7 60A molded case switch B60NARNM-A2 QO200TRNM TPNA60R1 WNAS2060PL — P065NA1 7 30A fused with 15A ground fault receptacle DPF221RGF15WRTR — — — — — 30A fused with 20A ground fault receptacle DPF221RGF20WRTR — — — — — 7 60A fused with 15A ground fault receptacle DPF222RGF15WRTR — — — — — 60A fused with 20A ground fault receptacle DPF222RGF20WRTR — — — — — 7 60A non-fused with 15A ground fault receptacle DPU222RGF15WRTR — — — — — 60A non-fused with 20A ground fault receptacle DPU222RGF20WRTR — — — U3822-20GWR — 7 7 7 Note 1 Eaton Quick ProSM designated item. 7 7 7 7 7 7 V1-T7-6 Volume 1—Residential and Light Commercial CA08100002E—August 2012 www.eaton.com Air Conditioning Disconnects Fused, Unfused and Molded Case Switch 7.1 Technical Data and Specifications ● ● ● ● 10,000 amperes rms symmetrical interrupting rating Horsepower rated Fusible and non-fusible pullout and molded case switch designs 30 and 60 amperes available in fusible ● ● ● 7 60 amperes available in non-fusible and molded case switch Class H fuse clips provided on fusible pullout design WRTR (weather-resistant/ tamper-resistant) receptacle options available 7 7 7 7 7 Dimensions Approximate Dimensions in Inches (mm) 7 Dimensions and Shipping Carton Information 7 Catalog Number Carton Quantity 7 Dimensions in Inches (mm) Height Width Depth Weight Lbs (kg) 7 Metallic/Galvanized Steel Enclosure DPF221R 10 8.70 (220.9) 5.40 (137.2) 3.15 (80.0) 27 (12) DPF222R 10 8.70 (220.9) 5.40 (137.2) 3.15 (80.0) 27 (12) DPU222R 10 8.70 (220.9) 5.40 (137.2) 3.15 (80.0) 27 (12) DPB222R 10 8.60 (218.4) 5.30 (134.6) 3.74 (95.0) 34 (15) DPU222R12W 1 1 14.75 (374.6) 12.50 (317.5) 4.00 (101.6) 6 (3) DPU222R34W 1 1 14.75 (374.6) 12.50 (317.5) 4.00 (101.7) 6 (3) DPU222RGF20 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4) DPF221RGF20 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4) DPF222RGF20 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4) DPU222RGF15 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4) DPF221RGF15 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4) DPF222RGF15 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4) DPF221RGF15WRTR 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4) DPF221RGF20WRTR 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4) DPF222RGF15WRTR 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4) DPF222RGF20WRTR 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4) 7 7 7 7 7 7 7 7 7 7 DPU222RGF15WRTR 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4) DPU222RGF20WRTR 1 13.00 (330.2) 7.50 (190.5) 4.75 (120.7) 8 (4) DPU362R 1 8.60 (218.4) 5.30 (134.6) 3.74 (94.9) 4 (2) 7 8.63 (219.0) 6.26 (159.0) 4.33 (109.9) 15 (7) 7 Non-Metallic/Polycarbonate Enclosure ACD221RNM-A2 10 ACD222RNM-A2 10 8.63 (219.0) 6.26 (159.0) 4.33 (109.9) 15 (7) ACD222URNM-A2 10 8.63 (219.0) 6.26 (159.0) 4.33 (109.9) 15 (7) B60NARNM-A2 10 8.63 (219.0) 6.26 (159.0) 4.33 (109.9) 18 (8) 7 7 Note 1 Eaton Quick Pro designated item. 7 7 7 7 7 7 Volume 1—Residential and Light Commercial CA08100002E—August 2012 www.eaton.com V1-T7-7 7.1 Air Conditioning Disconnects Fused, Unfused and Molded Case Switch 7 Approximate Dimensions in Inches (mm) 7 DPF221R, DPF222R, DPU222R, DPU222R12W and DPU222R34W 7 4.00 (101.6) 7 3.15 (80.1) 7 5.40 (137.2) 7 7 2.00 (50.8) 0.25 (6.4) 2.54 (64.4) 1.11 (28.2) 1.47 (37.2) 7 7 5.14 (130.6) 7 8.79 (223.4) 7 8.70 (221.0) 5.26 (133.6) 7 7 0.26 (6.5) Dia. 3 Holes Req’d. 7 1.65 (41.9) 7 5.25 (133.5) 7 1.09 (27.7) 1.13 (28.7) 7 1.00 (25.4) 2.97 (75.3) 7 7 Knockouts for 1/2 (12.7), 3/4 (19.1) or 1 (25.4) Conduit 7 7 1.13 (28.7) 7 1.50 (38.1) 7 1.05 (26.7) 7 3.00 (76.2) 0.55 (14.0) 0.28 (7.1) Diameter Knockout—1 Req‘d. 7 7 7 7 7 7 V1-T7-8 Volume 1—Residential and Light Commercial CA08100002E—August 2012 1.55 (39.4) 5.10 (129.5) 2.39 (60.8) 7 1.55 (39.4) www.eaton.com 7.1 Air Conditioning Disconnects Fused, Unfused and Molded Case Switch Approximate Dimensions in Inches (mm) 7 ACD221RNM-A2, ACD222RNM-A2, ACD222URNM-A2 and B60NARNM-A2 7 6.26 (159.0) 4.33 (110.2) 7 0.90 (22.9) 0.20 (5.1) DIA. 7 7 7 7.03 (178.7) 8.69 (220.8) 8.36 (212.2) 0.96 (24.4) 7 7 0.21 (5.3) DIA. 1.00 (25.4) 7 7 1 Knockout for 0.50 (12.7), 1.00 (25.4), 1.25 (31.8) Conduit 1.83 (46.4) 1.35 (34.3) 4.08 (103.6) 0.81 (20.6) 1.05 (26.5) 1.95 (49.5) 4.20 (106.6) 1.76 (44.7) 3.52 (89.3) 7 6.00 (152.4) 7 7 4 Knockouts for 0.75 (19.1) or 1.00 (25.4) Conduit 1.35 (34.3) 1.36 (34.5) 7 1.95 (49.5) 2 Knockouts for 0.50 (12.7), 0.75 (19.1) or 1.00 (25.4) Conduit 7 7 7 DPB222R and DPU362A 7 7 7 7 7 8.60 (218.4) 7 7 7 3.74 (94.9) 7 7 7 7 5.30 (134.6) 7 Volume 1—Residential and Light Commercial CA08100002E—August 2012 www.eaton.com V1-T7-9 7.1 Air Conditioning Disconnects Fused, Unfused and Molded Case Switch 7 Approximate Dimensions in Inches (mm) 7 DPU222RGF20, DPF221RGF20, DPF222RGF20, DPU222RGF15, DPF221RGF15, DPF222RGF15, DPF221RGF15WRTR, DPF221RGF20WRTR, DPF222RGF15WRTR, DPF222RGF20WRTR, DPU222RGF15WRTR and DPU222RGF20WRTR 7 6.63 (168.4) 7 4.44 (112.8) 0.25 (6.4) Dia. Hole 3 Places 7 7 7 7 7 7 LINE LINE 11.63 (295.4) 10.25 (260.4) 7 8.75 (222.3) 7 7 2.31 (58.7) 7 7 7 1.44 (36.6) 0.75, 1.00, 1.25, 1.50 (19.1, 25.4, 31.8, 38.1) Knockouts 20A GFCI Receptacle 7 7 1.18 (30.0) 1.69 (42.9) 0.69 (17.5) 0.50, 0.75, 1.00 (12.7, 19.1, 25.4) Knockouts 5.13 (130.3) 6.25 (158.8) 7 4.06 (103.1) 1.25 (31.8) 0.50, 0.75 (12.7, 19.1) Knockouts 0.94 (23.9) 7 4.44 (112.8) 7 7 7 7 7 7 7 7 7 7 V1-T7-10 Volume 1—Residential and Light Commercial CA08100002E—August 2012 4.31 (109.5) www.eaton.com Appendix 1—Eaton Terms & Conditions Effective Date: November 1, 2008 Contents Eaton Terms & Conditions Description Page Terms and Conditions of Sale. . . . . . . . . . . . . . . . . Terms of Payment . . . . . . . . . . . . . . . . . . . . . . . . . Freight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-A1-1 V1-A1-2 V1-A1-3 V1-A1-3 Selling Policy (Supersedes Selling Policy 25-000, dated February 20, 2006) Terms and Conditions of Sale The Terms and Conditions of Sale set forth herein, and any supplements which may be attached hereto, constitute the full and final expression of the contract for the sale of products or services (hereinafter referred to as Product(s) or Services by Eaton Corporation (hereinafter referred to as Seller) to the Buyer, and supersedes all prior quotations, purchase orders, correspondence or communications whether written or oral between the Seller and the Buyer. Notwithstanding any contrary language in the Buyer’s purchase order, correspondence or other form of acknowledgment, Buyer shall be bound by these Terms and Conditions of Sale when it sends a purchase order or otherwise indicates acceptance of this contract, or when it accepts delivery from Seller of the Products or Services. THE CONTRACT FOR SALE OF THE PRODUCTS OR SERVICES IS EXPRESSLY LIMITED TO THE TERMS AND CONDITIONS OF SALE STATED HEREIN. ANY ADDITIONAL OR DIFFERENT TERMS PROPOSED BY BUYER ARE REJECTED UNLESS EXPRESSLY AGREED TO IN WRITING BY SELLER. No contract shall exist except as herein provided. Complete Agreement No amendment or modification hereto nor any statement, representation or warranty not contained herein shall be binding on the Seller unless made in writing by an authorized representative of the Seller. Prior dealings, usage of the trade or a course of performance shall not be relevant to determine the meaning of this contract even though the accepting or acquiescing party had knowledge of the nature of the performance and opportunity for objection. Quotations Written quotations are valid for 30 days from its date unless otherwise stated in the quotation or terminated sooner by notice. Verbal quotations, unless accepted, expire the same day they are made. A complete signed order must be received by Seller within 20 calendar days of notification of award, otherwise the price and shipment will be subject to re-negotiation. Volume 1—Residential and Light Commercial CA08100002E—June 2013 Termination and Cancellation Any order may be terminated by the Buyer only by written notice and upon payment of reasonable termination charges, including all costs plus profit. Seller shall have the right to cancel any order at any time by written notice if Buyer breaches any of the terms hereof, becomes the subject of any proceeding under state or federal law for the relief of debtors, or otherwise becomes insolvent or bankrupt, generally does not pay its debts as they become due or makes an assignment for the benefit of creditors. www.eaton.com V1-A1-1 Appendix 1—Eaton Terms & Conditions Effective Date: November 1, 2008 Prices All prices are subject to change without notice. In the event of a price change, the effective date of the change will be the date of the new price or discount sheet, letter or telegram. All quotations made or orders accepted after the effective date will be on the new basis. For existing orders, the price of the unshipped portion of an order will be the price in effect at time of shipment. Price Policy—Products and Services When prices are quoted as firm for quoted shipment, they are firm provided the following conditions are met: 1. The order is released with complete engineering details. 2. Shipment of Products are made, and Services purchased are provided within the quoted lead time. 3. When drawings for approval are required for any Products, the drawings applicable to those Products must be returned within 30* calendar days from the date of the original mailing of the drawings by Seller. The return drawings must be released for manufacture and shipment and must be marked “APPROVED” or “APPROVED AS NOTED.” Drawing re-submittals which are required for any other reason than to correct Seller errors will not extend the 30-day period. If the Buyer initiates or in any way causes delays in shipment, provision of Services or return of approval drawings beyond the periods stated above, the price of the Products or Services will be increased 1% per month or fraction thereof up to a maximum of 18 months from the date of the Buyer’s order. For delays resulting in shipment or provision of Services beyond 18 months from the date of the Buyer’s order, the price must be renegotiated. Price Policy—BLS Refer to Price Policy 25-050. Minimum Billing Orders less than $1,000 will be assessed a shipping and handling charge of 5% of the price of the order, with a minimum charge of $25.00 unless noted differently on Product discount sheets. Taxes The price does not include any taxes. Buyer shall be responsible for the payment of all taxes applicable to, or arising from the transaction, the Products, its sale, value, or use, or any Services performed in connection therewith regardless of the person or entity actually taxed. Terms of Payment Products Acceptance of all orders is subject to the Buyer meeting Seller’s credit requirements. Terms of payment are subject to change for failure to meet such requirements. Seller reserves the right at any time to demand full or partial payment before proceeding with a contract of sale as a result of changes in the financial condition of the Buyer. Terms of Payment are either Net 30 days from the date of invoice of each shipment or carry a cash discount based on Product type. Specific payment terms for Products are outlined in the applicable Product discount schedules. Services Terms of payment are net within 30 days from date of invoice for orders amounting to less than $50,000.00. Terms of payment for orders exceeding $50,000.00 shall be made according to the following: 1. Twenty percent (20%) of order value with the purchase order payable 30 days from date of invoice. 2. Eighty percent (80%) of order value in equal monthly payments over the performance period payable 30 days from date of invoice. * 60 days for orders through contractors to allow time for their review and approval before and after transmitting them to their customers. V1-A1-2 Volume 1—Residential and Light Commercial CA08100002E—June 2013 www.eaton.com Except for work performed (i) under a firm fixed price basis or (ii) pursuant to terms of a previously priced existing contract between Seller and Buyer, invoices for work performed by Seller shall have added and noted on each invoice a charge of 3% (over and above the price of the work) which is related to Seller compliance with present and proposed environmental, health, and safety regulations associated with prescribed requirements covering hazardous materials management and employee training, communications, personal protective equipment, documentation and record keeping associated therewith. Adequate Assurances If, in the judgment of Seller, the financial condition of the Buyer, at any time during the period of the contract, does not justify the terms of payment specified, Seller may require full or partial payment in advance. Delayed Payment If payments are not made in accordance with these terms, a service charge will, without prejudice to the right of Seller to immediate payment, be added in an amount equal to the lower of 1.5% per month or fraction thereof or the highest legal rate on the unpaid balance. Appendix 1—Eaton Terms & Conditions Effective Date: November 1, 2008 Freight Warranty Freight policy will be listed on the Product discount sheets, or at option of Seller one of the following freight terms will be quoted. Risk of Loss Risk of loss or damage to the Products shall pass to Buyer at the F.O.B. point. F.O.B.—P/S—Frt./Ppd. and Invoiced Products are sold F.O.B. point of shipment freight prepaid and invoiced to the Buyer. Concealed Damage Except in the event of F.O.B. destination shipments, Seller will not participate in any settlement of claims for concealed damage. F.O.B.—P/S—Frt./Ppd. and Allowed Products sold are delivered F.O.B. point of shipment, freight prepaid and included in the price. F.O.B. Destination—Frt./Ppd. and Allowed At Buyer’s option, Seller will deliver the Products F.O.B. destination freight prepaid and 2% will be added to the net price. The term “freight prepaid” means that freight charges will be prepaid to the accessible common carrier delivery point nearest the destination for shipments within the United States and Puerto Rico unless noted differently on the Product discount sheets. For any other destination contact Seller’s representative. Shipment and Routing Seller shall select the point of origin of shipment, the method of transportation, the type of carrier equipment and the routing of the shipment. If the Buyer specifies a special method of transportation, type of carrier equipment, routing, or delivery requirement, Buyer shall pay all special freight and handling charges. When freight is included in the price, no allowance will be made in lieu of transportation if the Buyer accepts shipment at factory, warehouse, or freight station or otherwise supplies its own transportation. When shipment has been made on an F.O.B. destination basis, the Buyer must unpack immediately and, if damage is discovered must: 1. Not move the Products from the point of examination. 2. Retain shipping container and packing material. 3. Notify the carrier in writing of any apparent damage. 4. Notify Seller representative within 72 hours of delivery. 5. Send Seller a copy of the carrier’s inspection report. Witness Tests/Customer Inspection Standard factory tests may be witnessed by the Buyer at Seller’s factory for an additional charge calculated at the rate of $2,500 per day (not to exceed eight (8) hours) per Product type. Buyer may final inspect Products at the Seller’s factory for $500 per day per Product type. Witness tests will add one (1) week to the scheduled shipping date. Seller will notify Buyer fourteen (14) calendar days prior to scheduled witness testing or inspection. In the event Buyer is unable to attend, the Parties shall mutually agree on a rescheduled date. However, Seller reserves the right to deem the witness tests waived with the right to ship and invoice Products. Held Orders For any order held, delayed or rescheduled at the request of the Buyer, Seller may, at its sole option (1) require payment to be based on any reasonable basis, including but not limited to the contract price, and any additional expenses, or cost resulting from such a delay; (2) store Products at the sole cost and risk of loss of the Buyer; and/ or (3) charge to the Buyer those prices under the applicable price policy. Payment for such price, expenses and costs, in any such event, shall be due by Buyer within thirty (30) days from date of Seller’s invoice. Any order so held delayed or rescheduled beyond six (6) months will be treated as a Buyer termination. Warranty for Products Seller warrants that the Products manufactured by it will conform to Seller’s applicable specifications and be free from failure due to defects in workmanship and material for one (1) year from the date of installation of the Product or eighteen (18) months from the date of shipment of the Product, whichever occurs first. Drawing Approval Seller will design the Products in line with, in Seller’s judgment, good commercial practice. If at drawing approval Buyer makes changes outside of the design as covered in their specifications, Seller will then be paid reasonable charges and allowed a commensurate delay in shipping date based on the changes made. Seller requires all nonconforming Products be returned at Seller’s expense for evaluation unless specifically stated otherwise in writing by Seller. Drawing Re-Submittal When Seller agrees to do so in its quotation, Seller shall provide Buyer with the first set of factory customer approval drawing(s) at Seller’s expense. The customer approval drawing(s) will be delivered at the quoted delivery date. If Buyer requests drawing changes or additions after the initial factory customer approval drawing(s) have been submitted by Seller, the Seller, at its option, may assess Buyer drawing charges. Factory customer approval drawing changes required due to misinterpretation by Seller will be at Seller’s expense. Approval drawings generated by Bid Manager are excluded from this provision. Volume 1—Residential and Light Commercial CA08100002E—June 2013 In the event any Product fails to comply with the foregoing warranty Seller will, at its option, either (a) repair or replace the defective Product, or defective part or component thereof, F.O.B. Seller’s facility freight prepaid, or (b) credit Buyer for the purchase price of the Product. All warranty claims shall be made in writing. This warranty does not cover failure or damage due to storage, installation, operation or maintenance not in conformance with Seller’s recommendations and industry standard practice or due to accident, misuse, abuse or negligence. This warranty does not cover reimbursement for labor, gaining access, removal, installation, temporary power or any other expenses, which may be incurred in connection with repair or replacement. This warranty does not apply to equipment not manufactured by Seller. Seller limits itself to extending the same warranty it receives from the supplier. www.eaton.com V1-A1-3 Appendix 1—Eaton Terms & Conditions Effective Date: November 1, 2008 Extended Warranty for Products If requested by the Buyer and specifically accepted in writing by Seller, the foregoing standard warranty for Products will be extended from the date of shipment for the period and price indicated below: ● ● ● 24 months—2% of Contract Price 30 months—3% of Contract Price 36 months—4% of Contract Price Special Warranty (In and Out) for Products If requested by the Buyer and specifically accepted in writing by Seller, Seller will, during the warranty period for Products, at an additional cost of 2% of the contract price, be responsible for the direct cost of: 1. Removing the Product from the installed location. 2. Transportation to the repair facility and return to the site. 3. Reinstallation on site. The total liability of Seller for this Special Warranty for Products is limited to 50% of the contract price of the particular Product being repaired and excludes expenses for removing adjacent apparatus, walls, piping, structures, temporary service, etc. V1-A1-4 Warranty for Services Seller warrants that the Services performed by it hereunder will be performed in accordance with generally accepted professional standards. The Services, which do not so conform, shall be corrected by Seller upon notification in writing by the Buyer within one (1) year after completion of the Services. Unless otherwise agreed to in writing by Seller, Seller assumes no responsibility with respect to the suitability of the Buyer’s, or its customer’s, equipment or with respect to any latent defects in equipment not supplied by Seller. This warranty does not cover damage to Buyer’s, or its customer’s, equipment, components or parts resulting in whole or in part from improper maintenance or operation or from their deteriorated condition. Buyer will, at its cost, provide Seller with unobstructed access to the defective Services, as well as adequate free working space in the immediate vicinity of the defective Services and such facilities and systems, including, without limitation, docks, cranes and utility disconnects and connects, as may be necessary in order that Seller may perform its warranty obligations. The conducting of any tests shall be mutually agreed upon and Seller shall be notified of, and may be present at, all tests that may be made. Volume 1—Residential and Light Commercial Warranty for Power Systems Studies Seller warrants that any power systems studies performed by it will conform to generally accepted professional standards. Any portion of the study, which does not so conform, shall be corrected by Seller upon notification in writing by the Buyer within six (6) months after completion of the study. All warranty work shall be performed in a single shift straight time basis Monday through Friday. In the event that the study requires correction of warranty items on an overtime schedule, the premium portion of such overtime shall be for the Buyer’s account. Limitation on Warranties for Products, Services and Power Systems Studies THE FOREGOING WARRANTIES ARE EXCLUSIVE EXCEPT FOR WARRANTY OF TITLE. SELLER DISCLAIMS ALL OTHER WARRANTIES INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. CORRECTION OF NONCONFORMITIES IN THE MANNER AND FOR THE PERIOD OF TIME PROVIDED ABOVE SHALL CONSTITUTE SELLER’S SOLE LIABILITY AND BUYER’S EXCLUSIVE REMEDY FOR FAILURE OF SELLER TO MEET ITS WARRANTY OBLIGATIONS, WHETHER CLAIMS OF THE BUYER ARE BASED IN CONTRACT, IN TORT (INCLUDING NEGLIGENCE OR STRICT LIABILITY), OR OTHERWISE. CA08100002E—June 2013 www.eaton.com Asbestos Federal Law requires that building or facility owners identify the presence, location and quantity of asbestos containing material (hereinafter “ACM”) at work sites. Seller is not licensed to abate ACM. Accordingly, for any contract which includes the provision of Services, prior to (i) commencement of work at any site under a specific Purchase Order, (ii) a change in the work scope of any Purchase Order, the Buyer will certify that the work area associated with the Seller’s scope of work includes the handling of Class II ACM, including but not limited to generator wedges and high temperature gaskets which include asbestos materials. The Buyer shall, at its expense, conduct abatement should the removal, handling, modification or reinstallation, or some or all of them, of said Class II ACM be likely to generate airborne asbestos fibers; and should such abatement affect the cost of or time of performance of the work then Seller shall be entitled to an equitable adjustment in the schedule, price and other pertinent affected provisions of the contract. Compliance with Nuclear Regulation Seller’s Products are sold as commercial grade Products not intended for application in facilities or activities licensed by the United States Nuclear Regulatory Commission for atomic purposes. Further certification will be required for use of the Products in any safety-related application in any nuclear facility licensed by the U.S. Nuclear Regulatory Commission. Appendix 1—Eaton Terms & Conditions Effective Date: November 1, 2008 Returning Products Authorization and shipping instructions for the return of any Products must be obtained from Seller before returning the Products. When return is occasioned due to Seller error, full credit including all transportation charges will be allowed. Product Notices Buyer shall provide the user (including its employees) of the Products with all Seller supplied Product notices, warnings, instructions, recommendations, and similar materials. Force Majeure Seller shall not be liable for failure to perform or delay in performance due to fire, flood, strike or other labor difficulty, act of God, act of any governmental authority or of the Buyer, riot, embargo, fuel or energy shortage, car shortage, wrecks or delays in transportation, or due to any other cause beyond Seller’s reasonable control. In the event of delay in performance due to any such cause, the date of delivery or time for completion will be extended by a period of time reasonably necessary to overcome the effect of such delay. Liquidated Damages Contracts which include liquidated damage clauses for failure to meet shipping or job completion promises are not acceptable or binding on Seller, unless such clauses are specifically accepted in writing by an authorized representative of the Seller at its headquarters office. Patent Infringement Seller will defend or, at its option, settle any suit or proceeding brought against Buyer, or Buyer’s customers, to the extent it is based upon a claim that any Product or part thereof, manufactured by Seller or its subsidiaries and furnished hereunder, infringes any United States patent, other than a claim of infringement based upon use of a Product or part thereof in a process, provided Seller is notified in reasonable time and given authority, information and assistance (at Seller’s expense) for the defense of same. Seller shall pay all legal and court costs and expenses and courtassessed damages awarded therein against Buyer resulting from or incident to such suit or proceeding. In addition to the foregoing, if at any time Seller determines there is a substantial question of infringement of any United States patent, and the use of such Product is or may be enjoined, Seller may, at its option and expense: either (a) procure for Buyer the right to continue using and selling the Product; (b) replace the Product with non-infringing apparatus; (c) modify the Product so it becomes noninfringing; or (d) as a last resort, remove the Product and refund the purchase price, equitably adjusted for use and obsolescence. In no case does Seller agree to pay any recovery based upon its Buyer’s savings or profit through use of Seller’s Products whether the use be special or ordinary. The foregoing states the entire liability of Seller for patent infringement. The preceding paragraph does not apply to any claim of infringement based upon: (a) any modification made to a Product other than by Seller; (b) any design and/or specifications of Buyer to which a Product was manufactured; or (c) the use or combination of Product with other products where the Product does not itself infringe. As to the aboveidentified claim situations where the preceding paragraph does not apply, Buyer shall defend and hold Seller harmless in the same manner and to the extent as Seller’s obligations described in the preceding paragraph. Buyer shall be responsible for obtaining (at Buyer’s expense) all license rights required for Seller to be able to use software products in the possession of Buyer where such use is required in order to perform any Service for Buyer. With respect to a Product or part thereof not manufactured by Seller or its subsidiaries, Seller will attempt to obtain for Buyer, from the supplier(s), the patent indemnification protection normally provided by the supplier(s) to customers. Volume 1—Residential and Light Commercial CA08100002E—June 2013 Limitation of Liability THE REMEDIES OF THE BUYER SET FORTH IN THIS CONTRACT ARE EXCLUSIVE AND ARE ITS SOLE REMEDIES FOR ANY FAILURE OF SELLER TO COMPLY WITH ITS OBLIGATIONS HEREUNDER. NOTWITHSTANDING ANY PROVISION IN THIS CONTRACT TO THE CONTRARY, IN NO EVENT SHALL SELLER BE LIABLE IN CONTRACT, IN TORT (INCLUDING NEGLIGENCE OR STRICT LIABILITY) OR OTHERWISE FOR DAMAGE TO PROPERTY OR EQUIPMENT OTHER THAN PRODUCTS SOLD HEREUNDER, LOSS OF PROFITS OR REVENUE, LOSS OF USE OF PRODUCTS, COST OF CAPITAL, CLAIMS OF CUSTOMERS OF THE BUYER OR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES WHATSOEVER, REGARDLESS OF WHETHER SUCH POTENTIAL DAMAGES ARE FORESEEABLE OR IF SELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. THE TOTAL CUMULATIVE LIABILITY OF SELLER ARISING FROM OR RELATED TO THIS CONTRACT WHETHER THE CLAIMS ARE BASED IN CONTRACT, IN TORT (INCLUDING NEGLIGENCE OR STRICT LIABILITY) OR OTHERWISE, SHALL NOT EXCEED THE PRICE OF THE PRODUCT OR SERVICES ON WHICH SUCH LIABILITY IS BASED. www.eaton.com V1-A1-5 Appendix 2—Catalog Parent Number Index A ACD. . . . . . . . . . . ACD2. . . . . . . . . . ARP . . . . . . . . . . . ARP0 . . . . . . . . . . C V1-T7-4, V1-T7-6 V1-T7-4, V1-T7-6 V1-T5-77, V1-T6-8 V1-T5-30, V1-T5-33, V1-T5-85 B BD . . . . . . . . . . . . BH . . . . . . . . . . . . BHG. . . . . . . . . . . BHL . . . . . . . . . . . BHT . . . . . . . . . . . BIN . . . . . . . . . . . BINA . . . . . . . . . . BJ . . . . . . . . . . . . BJH . . . . . . . . . . . BJL . . . . . . . . . . . BQ . . . . . . . . . . . . BQC. . . . . . . . . . . BR . . . . . . . . . . . . BRB . . . . . . . . . . . BRC . . . . . . . . . . . BRD. . . . . . . . . . . BRE . . . . . . . . . . . BRF . . . . . . . . . . . BRG. . . . . . . . . . . BRH. . . . . . . . . . . BRHH . . . . . . . . . BRL . . . . . . . . . . . BRL2 . . . . . . . . . . BRM . . . . . . . . . . BRP . . . . . . . . . . . BRQ. . . . . . . . . . . BRR . . . . . . . . . . . BRS . . . . . . . . . . . BRSF . . . . . . . . . . BRSUR . . . . . . . . BRW . . . . . . . . . . BR1 . . . . . . . . . . . BR2 . . . . . . . . . . . BR3 . . . . . . . . . . . BR4 . . . . . . . . . . . BR5 . . . . . . . . . . . BR6 . . . . . . . . . . . BR8 . . . . . . . . . . . BSS . . . . . . . . . . . BW . . . . . . . . . . . BWFP . . . . . . . . . B424 . . . . . . . . . . B60N . . . . . . . . . . V1-T1-80 V1-T1-84 V1-T1-84 V1-T1-84 V1-T1-84 V1-T1-25 V1-T1-22, V1-T1-25, V1-T1-60, V1-T1-91 V1-T1-83, V1-T1-84 V1-T1-83, V1-T1-84 V1-T1-85 V1-T1-80 V1-T1-82 V1-T2-8 V1-T1-26 V1-T1-26 V1-T1-26, V1-T1-81, V1-T1-84 V1-T1-84 V1-T1-60 V1-T1-26, V1-T1-58, V1-T1-65, V1-T1-92 V1-T1-52, V1-T1-76, V1-T1-77, V1-T1-84, V1-T5-98, V1-T5-125 V1-T1-76, V1-T5-98, V1-T5-125 V1-T1-26, V1-T1-52, V1-T1-60, V1-T1-77, V1-T1-84 V1-T1-78 V1-T1-60, V1-T1-85 V1-T1-85 V1-T1-84 V1-T1-60 V1-T1-15, V1-T1-52, V1-T1-60, V1-T1-83, V1-T5-137 V1-T5-137 V1-T1-15, V1-T2-7 V1-T1-83 V1-T1-46–V1-T1-49, V1-T1-51, V1-T1-53, V1-T158, V1-T1-59, V1-T1-76, V1-T1-77, V1-T1-81 V1-T1-46–V1-T1-49, V1-T1-51–V1-T1-52, V1-T158, V1-T1-59, V1-T1-76, V1-T1-81, V1-T1-83, V1T5-98, V1-T5-125, V1-T6-22 V1-T1-46–V1-T1-47, V1-T1-49, V1-T1-51–V1-T152, V1-T1-58, V1-T1-59, V1-T1-77, V1-T1-81 V1-T1-46–V1-T1-49, V1-T1-51–V1-T1-53, V1-T1-81 V1-T1-57 V1-T1-48 V1-T1-46, V1-T1-48, V1-T1-49, V1-T1-51, V1-T1-52 V1-T1-22, V1-T1-60 V1-T1-60, V1-T1-94, V1-T5-43 V1-T1-60 V1-T1-47 V1-T7-4, V1-T7-6 CC . . . . . . . . . . . CCH . . . . . . . . . . CCL . . . . . . . . . . CCV . . . . . . . . . . CCVH . . . . . . . . . CCV2 . . . . . . . . . CC3 . . . . . . . . . . CG . . . . . . . . . . . CH . . . . . . . . . . . CHB . . . . . . . . . . CHE . . . . . . . . . . CHEC . . . . . . . . . CHEG . . . . . . . . . CHF . . . . . . . . . . CHFL . . . . . . . . . CHG . . . . . . . . . . CHH . . . . . . . . . . CHI. . . . . . . . . . . CHL . . . . . . . . . . CHLD . . . . . . . . . CHLDF . . . . . . . . CHM . . . . . . . . . CHMM . . . . . . . . CHM1 . . . . . . . . CHM4 . . . . . . . . CHM5 . . . . . . . . CHM7 . . . . . . . . CHN . . . . . . . . . . CHOU . . . . . . . . CHP . . . . . . . . . . CHPA . . . . . . . . . CHPE . . . . . . . . . CHPO. . . . . . . . . CHQ . . . . . . . . . . CHR . . . . . . . . . . CHR1 . . . . . . . . . CHR3 . . . . . . . . . CHR7 . . . . . . . . . CHS . . . . . . . . . . CHSA . . . . . . . . . CHSPC . . . . . . . . CHSPF . . . . . . . . CHSPT . . . . . . . . CHSP3 . . . . . . . . CHSUR. . . . . . . . CHT . . . . . . . . . . CHTE . . . . . . . . . CHU . . . . . . . . . . CHUD. . . . . . . . . CHU1 . . . . . . . . . CHU2 . . . . . . . . . CHU3 . . . . . . . . . CHU4 . . . . . . . . . CHU5 . . . . . . . . . CHU6 . . . . . . . . . CHU7 . . . . . . . . . Volume 1—Residential and Light Commercial V1-T1-38, V1-T1-56, V1-T1-84, V1-T1-95 V1-T1-95 V1-T1-38, V1-T1-84 V1-T1-95, V1-T5-95 V1-T1-95, V1-T5-95, V1-T5-98, V1-T5-135 V1-T5-95, V1-T5-98, V1-T5-125, V1-T5-135 V1-T1-95, V1-T5-135 V1-T5-76 V1-T1-89 V1-T1-22, V1-T1-60, V1-T6-8 V1-T1-16, V1-T1-23 V1-T2-7 V1-T3-14, V1-T3-18 V1-T1-22, V1-T1-32, V1-T1-33 V1-T6-7 V1-T1-25 V1-T1-38 V1-T6-8 V1-T1-11, V1-T1-16, V1-T1-38, V1-T6-8 V1-T6-8 V1-T6-8, V1-T6-9 V1-T1-22, V1-T1-38, V1-T5-41, V1-T6-12, V1-T6-17 V1-T5-41 V1-T6-12, V1-T6-17 V1-T6-17 V1-T6-12 V1-T6-12 V1-T1-22, V1-T1-25, V1-T6-9 V1-T6-9 V1-T1-24, V1-T1-36–V1-T1-38, V1-T6-23 V1-T6-7, V1-T6-23 V1-T6-7, V1-T6-23 V1-T6-8, V1-T6-9 V1-T2-8 V1-T1-22, V1-T6-12, V1-T6-17 V1-T6-12, V1-T6-17 V1-T6-12 V1-T6-12 V1-T1-15, V1-T1-16, V1-T1-22, V1-T1-25 V1-T2-8 V1-T2-6 V1-T2-6 V1-T2-4–V1-T2-6 V1-T2-6 V1-T2-7 V1-T1-35 V1-T6-7 V1-T5-84, V1-T5-85, V1-T6-11, V1-T6-17 V1-T6-9 V1-T6-11, V1-T6-17 V1-T5-84, V1-T6-11 V1-T6-11 V1-T6-11, V1-T6-17 V1-T6-11 V1-T6-11 V1-T6-11 CA08100002E—April 2014 www.eaton.com V1-A2-1 Appendix 2—Catalog Parent Number Index CHVH . . . . . . . . . CH1 . . . . . . . . . . . CH2 . . . . . . . . . . . CH2L . . . . . . . . . . CH3 . . . . . . . . . . . CH4 . . . . . . . . . . . CH4L . . . . . . . . . . CH5 . . . . . . . . . . . CH6 . . . . . . . . . . . CH7 . . . . . . . . . . . CH8 . . . . . . . . . . . CH8L . . . . . . . . . . CH9 . . . . . . . . . . . CMB . . . . . . . . . . CMBB . . . . . . . . . CMBE . . . . . . . . . CMBX . . . . . . . . . CSH . . . . . . . . . . . CSH2 . . . . . . . . . . CSR . . . . . . . . . . . CSR2 . . . . . . . . . . CVH . . . . . . . . . . . CVH2 . . . . . . . . . . CVS . . . . . . . . . . . CVS2 . . . . . . . . . . CV2 . . . . . . . . . . . CV3 . . . . . . . . . . . V1-T5-125 V1-T1-7, V1-T1-10, V1-T1-13, V1-T1-32–V1-T135, V1-T1-37, V1-T1-38, V1-T3-17, V1-T3-18, V1-T5-84 V1-T1-7–V1-T1-10, V1-T1-11, V1-T1-13, V1-T117, V1-T1-18, V1-T1-32–V1-T1-35, V1-T1-37, V1-T5-77, V1-T5-84, V1-T5-85 V1-T1-9 V1-T1-7, V1-T1-8, V1-T1-10–V1-T1-14, V1-T1-17, V1-T1-18, V1-T1-23, V1-T1-32–V1-T1-35, V1-T3-14 V1-T1-7–V1-T1-14, V1-T1-17, V1-T1-18, V1-T3-17, V1-T3-18 V1-T1-9 V1-T1-14, V1-T5-85 V1-T1-13, V1-T1-14, V1-T1-17, V1-T3-17, V1-T3-18 V1-T1-7, V1-T1-10–V1-T1-13, V1-T1-24 V1-T1-7–V1-T1-11, V1-T1-17, V1-T1-18, V1-T1-23, V1-T1-26, V1-T3-17, V1-T3-18 V1-T1-9 V1-T1-25, V1-T1-38, V1-T1-60 V1-T5-41, V1-T5-42, V1-T5-66 V1-T5-41 V1-T5-50, V1-T5-51, V1-T5-66, V1-T5-86 V1-T5-42 V1-T1-11, V1-T1-16 V1-T1-11, V1-T5-43 V1-T1-11, V1-T1-16, V1-T1-22, V1-T1-52, V1-T194, V1-T5-43, V1-T6-22 V1-T1-11, V1-T1-17, V1-T1-94, V1-T5-43 V1-T5-135 V1-T5-97, V1-T5-98, V1-T5-125 V1-T5-135 V1-T5-97, V1-T5-98, V1-T5-125 V1-T5-97, V1-T5-98, V1-T5-125, V1-T5-135 V1-T5-135 EPBQ . . . . . . . . . EPBS . . . . . . . . . EPBT . . . . . . . . . ESL . . . . . . . . . . ESWA . . . . . . . . ESWB . . . . . . . . ESWC . . . . . . . . ESWD . . . . . . . . ESWE. . . . . . . . . ESWF. . . . . . . . . ESWI . . . . . . . . . ESWM . . . . . . . . ESWN . . . . . . . . ESWP. . . . . . . . . ESWR . . . . . . . . ESWT. . . . . . . . . ESWV. . . . . . . . . V1-T5-34 V1-T5-34 V1-T5-34 V1-T5-34 V1-T4-10–V1-T4-13 V1-T4-4, V1-T4-20 V1-T4-15–V1-T4-17 V1-T4-7 V1-T4-12 V1-T4-8, V1-T4-15 V1-T4-14, V1-T4-20 V1-T4-8, V1-T4-9, V1-T4-20 V1-T4-8, V1-T4-9 V1-T4-8, V1-T4-21 V1-T4-18, V1-T4-19 V1-T4-6 V1-T4-5, V1-T4-9 G GB . . . . . . . . . . . GBK . . . . . . . . . . GFC . . . . . . . . . . GFE . . . . . . . . . . GHC . . . . . . . . . . GHQ . . . . . . . . . . GTAP . . . . . . . . . V1-T1-25, V1-T1-65, V1-T1-92 V1-T6-9 V1-T1-78, V1-T1-79 V1-T1-79 V1-T6-75 V1-T1-85 V1-T1-58 H HL . . . . . . . . . . . HPB . . . . . . . . . . HPC . . . . . . . . . . HPP . . . . . . . . . . HP2 . . . . . . . . . . HP4 . . . . . . . . . . HP8 . . . . . . . . . . V1-T1-84 V1-T5-77 V1-T5-76 V1-T5-77 V1-T5-77 V1-T5-76, V1-T5-77 V1-T5-76 I D DPB . . . . . . . . . . . DPB2 . . . . . . . . . . DPF . . . . . . . . . . . DPF2 . . . . . . . . . . DPU . . . . . . . . . . . DPU2. . . . . . . . . . DS . . . . . . . . . . . . DS1 . . . . . . . . . . . DS2 . . . . . . . . . . . DS3 . . . . . . . . . . . DS9 . . . . . . . . . . . IMM . . . . . . . . . . V1-T7-4, V1-T7-6 V1-T7-4, V1-T7-6 V1-T7-4–V1-T7-6 V1-T7-4–V1-T7-6 V1-T7-4–V1-T7-6 V1-T7-4–V1-T7-5 V1-T1-25, V1-T1-65, V1-T6-7 V1-T5-67 V1-T5-67 V1-T5-67 V1-T5-67 E ECB . . . . . . . . . . . ECC . . . . . . . . . . . EDL . . . . . . . . . . . EGEN. . . . . . . . . . EGS . . . . . . . . . . . EHD . . . . . . . . . . . EPBD. . . . . . . . . . V1-A2-2 V1-T1-94 V1-T1-95 V1-T5-34 V1-T3-3, V1-T3-4 V1-T3-18 V1-T5-135 V1-T5-34 Volume 1—Residential and Light Commercial V1-T5-67 J JT . . . . . . . . . . . . V1-T6-75 L LC . . . . . . . . . . . V1-T1-22, V1-T1-60 M MBB. . . . . . . . . . MBE. . . . . . . . . . MBED . . . . . . . . MBER . . . . . . . . MBE1. . . . . . . . . MBE2. . . . . . . . . MBE3. . . . . . . . . MBE4. . . . . . . . . MBE8. . . . . . . . . MBH . . . . . . . . . MBP. . . . . . . . . . MBT . . . . . . . . . . CA08100002E—April 2014 V1-T5-41 V1-T5-50, V1-T5-66 V1-T5-60 V1-T5-51 V1-T5-50, V1-T5-51 V1-T5-50, V1-T5-51 V1-T5-51 V1-T5-51 V1-T5-51 V1-T5-67 V1-T5-41 V1-T5-42 www.eaton.com Appendix 2—Catalog Parent Number Index MBX . . . . . . . . . . MB1 . . . . . . . . . . MB2 . . . . . . . . . . MB20 . . . . . . . . . MB4 . . . . . . . . . . MB5 . . . . . . . . . . MB8 . . . . . . . . . . MCB . . . . . . . . . . MCBK . . . . . . . . . MHD . . . . . . . . . . MHM. . . . . . . . . . MHP . . . . . . . . . . MHR . . . . . . . . . . MM . . . . . . . . . . . MPL. . . . . . . . . . . MPLFH . . . . . . . . MSEG . . . . . . . . . MSL. . . . . . . . . . . MST. . . . . . . . . . . V1-T5-41 V1-T5-42 V1-T5-66 V1-T5-42 V1-T5-42 V1-T5-67 V1-T5-42, V1-T5-66 V1-T1-38, V1-T1-84, V1-T1-94, V1-T5-43 V1-T1-94, V1-T5-43 V1-T6-23 V1-T6-22 V1-T6-23 V1-T6-22 V1-T5-137 V1-T6-75–V1-T6-77 V1-T6-77 V1-T2-6, V1-T5-35 V1-T5-140 V1-T5-140 N NL . . . . . . . . . . . . V1-T1-22, V1-T1-60 Q QCD . . . . . . . . . . QCF . . . . . . . . . . . QCGF . . . . . . . . . V1-T1-85 V1-T6-75 V1-T6-75 R RH . . . . . . . . . . . . RN . . . . . . . . . . . . RV . . . . . . . . . . . . V1-T1-65 V1-T1-18 V1-T6-75, V1-T6-77 S SPC . . . . . . . . . . . SP1 . . . . . . . . . . . SR . . . . . . . . . . . . SRL . . . . . . . . . . . ST . . . . . . . . . . . . STL . . . . . . . . . . . V1-T1-22, V1-T1-60 V1-T2-4 V1-T1-39, V1-T1-85, V1-T1-94 V1-T1-22, V1-T1-60 V1-T1-39 V1-T5-26 T TCD . . . . . . . . . . . TDL . . . . . . . . . . . TH . . . . . . . . . . . . TT120 . . . . . . . . . V1-T1-22, V1-T1-60 V1-T1-22, V1-T1-60 V1-T1-84 V1-T1-21 U UAHT. . . . . . . . . . UAST . . . . . . . . . . UAT . . . . . . . . . . . UATE . . . . . . . . . . UATH. . . . . . . . . . UATR. . . . . . . . . . UATZ . . . . . . . . . . UBEH . . . . . . . . . UBGT. . . . . . . . . . UBH. . . . . . . . . . . V1-T5-5 V1-T5-26 V1-T5-20 V1-T5-15 V1-T5-12, V1-T5-13 V1-T5-4–V1-T5-6 V1-T5-6, V1-T5-21 V1-T5-14 V1-T5-15 V1-T5-20, V1-T5-21 UBHR. . . . . . . . . UBHT . . . . . . . . . UBTE . . . . . . . . . UBTH . . . . . . . . . UBTR . . . . . . . . . UEHT . . . . . . . . . UETH . . . . . . . . . UE7 . . . . . . . . . . UFHT . . . . . . . . . UFT . . . . . . . . . . UFTE . . . . . . . . . UFTH . . . . . . . . . UFTR . . . . . . . . . UGE . . . . . . . . . . UGHR. . . . . . . . . UGHT . . . . . . . . . UGRS . . . . . . . . . UGTE . . . . . . . . . UGTH . . . . . . . . . UGTR . . . . . . . . . UHI. . . . . . . . . . . UHIR . . . . . . . . . UHT . . . . . . . . . . UHTR . . . . . . . . . UHTT . . . . . . . . . UH4 . . . . . . . . . . UH5 . . . . . . . . . . UH7 . . . . . . . . . . UIH. . . . . . . . . . . ULTS . . . . . . . . . UNRR. . . . . . . . . URRS . . . . . . . . . URS . . . . . . . . . . URT . . . . . . . . . . URTR . . . . . . . . . USTH . . . . . . . . . USTL . . . . . . . . . USTS . . . . . . . . . UST6 . . . . . . . . . UTE . . . . . . . . . . UTH . . . . . . . . . . UTRS . . . . . . . . . UTTE . . . . . . . . . UTTH . . . . . . . . . UTZR . . . . . . . . . UT2 . . . . . . . . . . UT3 . . . . . . . . . . UT4 . . . . . . . . . . UT5 . . . . . . . . . . UT6 . . . . . . . . . . U2R . . . . . . . . . . U2V . . . . . . . . . . U3R . . . . . . . . . . U3V . . . . . . . . . . U4R . . . . . . . . . . U5R . . . . . . . . . . U6R . . . . . . . . . . U921 . . . . . . . . . Volume 1—Residential and Light Commercial V1-T5-5, V1-T5-6, V1-T5-14 V1-T5-5 V1-T5-14 V1-T5-12, V1-T5-13 V1-T5-6 V1-T5-20 V1-T5-14 V1-T5-14 V1-T5-4–V1-T5-5 V1-T5-12, V1-T5-15 V1-T5-14 V1-T5-12 V1-T5-5 V1-T5-15 V1-T5-5 V1-T5-4–V1-T5-6, V1-T5-31 V1-T5-6 V1-T5-14, V1-T5-15 V1-T5-12 V1-T5-4, V1-T5-5, V1-T5-31 V1-T5-20 V1-T5-5 V1-T5-20, V1-T5-21 V1-T5-4–V1-T5-6, V1-T5-28, V1-T5-31 V1-T5-4, V1-T5-6, V1-T5-20 V1-T5-12 V1-T5-12 V1-T5-12 V1-T5-14 V1-T5-26 V1-T5-7 V1-T5-7 V1-T5-4, V1-T5-6, V1-T5-7 V1-T5-22 V1-T5-7 V1-T5-26 V1-T5-26 V1-T5-26 V1-T5-26 V1-T5-14, V1-T5-32 V1-T5-12, V1-T5-13, V1-T5-32 V1-T5-4–V1-T5-7, V1-T5-31 V1-T5-14, V1-T5-15 V1-T5-12 V1-T5-6 V1-T5-20, V1-T5-21 V1-T5-21 V1-T5-20, V1-T5-21 V1-T5-21 V1-T5-21 V1-T5-22 V1-T5-22 V1-T5-20, V1-T5-22 V1-T5-22 V1-T5-20–V1-T5-22 V1-T5-20–V1-T5-22 V1-T5-20 V1-T5-5 CA08100002E—April 2014 www.eaton.com V1-A2-3 Appendix 2—Catalog Parent Number Index W WCG . . . . . . . . . . V1-T5-136 Numerics 1BPS . . . . . . . . . . 1MCB . . . . . . . . . 1MFS. . . . . . . . . . 1MHC . . . . . . . . . 1MM . . . . . . . . . . 1MMA . . . . . . . . . 1MMB . . . . . . . . . 1MMC . . . . . . . . . 1MMG . . . . . . . . . 1MMJ . . . . . . . . . 1MMM . . . . . . . . 1MMP . . . . . . . . . 1MMR . . . . . . . . . 1MMS . . . . . . . . . 1MMW . . . . . . . . 1MM3 . . . . . . . . . 1MM4 . . . . . . . . . 1MM5 . . . . . . . . . 1MM6 . . . . . . . . . 1MPL. . . . . . . . . . 1MPS . . . . . . . . . 1MP2. . . . . . . . . . 1MP3. . . . . . . . . . 1MP4. . . . . . . . . . 1MP5. . . . . . . . . . 1MP6. . . . . . . . . . 1MTB . . . . . . . . . 1UGP . . . . . . . . . . 1003 . . . . . . . . . . 1004 . . . . . . . . . . 1005 . . . . . . . . . . 1006 . . . . . . . . . . 1007 . . . . . . . . . . 1008 . . . . . . . . . . 1009 . . . . . . . . . . 1010 . . . . . . . . . . 1212 . . . . . . . . . . 1224 . . . . . . . . . . 1624 . . . . . . . . . . 17NE . . . . . . . . . . 1836 . . . . . . . . . . 20NE . . . . . . . . . . 2024 . . . . . . . . . . 24IN. . . . . . . . . . . 24NE . . . . . . . . . . 2424 . . . . . . . . . . 2442 . . . . . . . . . . 2460 . . . . . . . . . . 3BPS . . . . . . . . . . 3BR . . . . . . . . . . . V1-A2-4 V1-T5-108 V1-T5-104, V1-T5-105 V1-T5-106, V1-T5-107 V1-T5-104, V1-T5-105 V1-T5-115, V1-T5-119, V1-T5-136, V1-T5-137, V1-T5-139 V1-T5-136 V1-T5-136–V1-T5-140 V1-T5-138 V1-T5-94 V1-T5-137 V1-T5-138 V1-T5-136 V1-T5-138 V1-T5-137 V1-T5-136, V1-T5-139 V1-T5-118, V1-T5-119 V1-T5-118, V1-T5-119 V1-T5-118, V1-T5-119, V1-T5-136 V1-T5-118, V1-T5-119 V1-T5-94 V1-T5-92–V1-T5-94 V1-T5-92, V1-T5-93 V1-T5-92, V1-T5-93 V1-T5-92, V1-T5-93 V1-T5-92, V1-T5-93 V1-T5-92, V1-T5-93 V1-T5-103 V1-T5-107 V1-T5-5, V1-T5-6 V1-T5-5, V1-T5-6, V1-T5-13, V1-T5-20, V1-T5-21, V1-T5-26 V1-T5-6 V1-T5-6, V1-T5-13, V1-T5-20, V1-T5-28 V1-T5-5, V1-T5-13, V1-T5-15, V1-T5-20, V1-T5-26 V1-T5-5, V1-T5-6, V1-T5-13, V1-T5-15, V1-T5-20, V1-T5-21, V1-T5-26, V1-T5-28 V1-T5-5–V1-T5-7, V1-T5-13–V1-T5-15, V1-T5-20, V1-T5-21, V1-T5-28 V1-T5-12 V1-T1-90 V1-T1-50, V1-T1-90 V1-T1-90 V1-T1-91 V1-T1-90 V1-T1-91 V1-T1-90 V1-T1-90 V1-T1-91 V1-T1-90 V1-T1-50, V1-T1-90 V1-T1-21 V1-T5-108 V1-T1-54–V1-T1-56, V1-T1-60 Volume 1—Residential and Light Commercial 3B42 . . . . . . . . . 3HM . . . . . . . . . . 3MC . . . . . . . . . . 3MCB. . . . . . . . . 3MF . . . . . . . . . . 3MFS . . . . . . . . . 3MHC . . . . . . . . 3MM . . . . . . . . . 3MMB . . . . . . . . 3MME . . . . . . . . 3MM2 . . . . . . . . 3MM3 . . . . . . . . 3MM4 . . . . . . . . 3MM5 . . . . . . . . 3MM6 . . . . . . . . 3MTB . . . . . . . . . 3UGP . . . . . . . . . 304. . . . . . . . . . . 3424. . . . . . . . . . 35MM . . . . . . . . 35NE . . . . . . . . . 35SS . . . . . . . . . 37M . . . . . . . . . . 37MM . . . . . . . . 37SS . . . . . . . . . 4242. . . . . . . . . . 47. . . . . . . . . . . . 48IN . . . . . . . . . . 49. . . . . . . . . . . . 612I . . . . . . . . . . 7821. . . . . . . . . . 7866. . . . . . . . . . 816I . . . . . . . . . . CA08100002E—April 2014 V1-T1-54 V1-T5-109 V1-T5-109 V1-T5-104, V1-T5-105, V1-T5-109 V1-T5-109 V1-T5-106, V1-T5-107, V1-T5-109 V1-T5-104, V1-T5-105 V1-T5-115, V1-T5-136, V1-T5-137 V1-T5-136 V1-T5-137, V1-T5-139 V1-T5-118–V1-T5-121 V1-T5-118–V1-T5-121 V1-T5-118–V1-T5-121, V1-T5-126 V1-T5-118–V1-T5-121, V1-T5-126 V1-T5-118–V1-T5-121 V1-T5-103 V1-T5-107 V1-T1-90 V1-T1-55 V1-T5-129 V1-T1-91 V1-T5-131 V1-T5-139 V1-T5-130, V1-T5-139, V1-T5-140 V1-T5-131 V1-T1-50, V1-T1-90 V1-T5-138, V1-T5-140 V1-T1-90 V1-T5-138, V1-T5-140 V1-T1-90 V1-T5-13 V1-T5-5 V1-T1-90 www.eaton.com Appendix 3—Alphabetical Product Index A A-BUS Products StructuredWiringSolutions “IR” Emitter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Audio Distribution Module . . . . . . . . . . . . . . . . . . . . Audio Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Audio Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cover Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Door Station . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Intercom Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Intercom Module . . . . . . . . . . . . . . . . . . . . . . . . . . . Interface Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Keypad . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Local Input Plate. . . . . . . . . . . . . . . . . . . . . . . . . . . . Remote Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . Volume Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-12 V1-T4-11 V1-T4-11 V1-T4-11 V1-T4-13 V1-T4-13 V1-T4-13 V1-T4-12 V1-T4-12 V1-T4-12 V1-T4-11 V1-T4-12 V1-T4-11 Access Panel Marina Power and Lighting Equipment/RV Park Hook-Ups Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-77 Accessories Manual Transfer Switches Flush Flange Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T3-18 Power Inlet Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T3-18 Marina Power and Lighting Equipment/RV Park Hook-Ups Access Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-77 Breaker Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75 Bus Bar Assembly . . . . . . . . . . . . . . . . . . V1-T6-76, V1-T6-77 Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75 Cover Set . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75 Digital Electronic Meters . . . . . . . . . . . . . . . . . . . . . V1-T6-76 Door Hasp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-77 External Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-76 Faceplate . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75–V1-T6-77 Fire Extinguisher. . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-77 Fluorescent Light Assembly. . . . . . . . . . . . . . . . . . . V1-T6-75 Fuse Holder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-76 Hose and Cable Brackets . . . . . . . . . . . . . . . . . . . . . V1-T6-75 Isolation Plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75 Lens . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-77 Life Ring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-77 Light and Lens Assembly . . . . . . . . . . . . . . . . . . . . . V1-T6-75 Light Fuse. . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-76, V1-T6-77 Light Holder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-77 Main Door. . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75, V1-T6-77 Main Housing . . . . . . . . . . . . . . . . . . . . . . V1-T6-75–V1-T6-77 Mounting Brackets . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-77 Mounting Feet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-76 Phone, Cable, Internet Assemblies . . . . . . . . . . . . . V1-T6-76 Receptacles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75 Spring Closure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75 Strobe Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-77 Water Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-76 Metering Products House Panel Accessories. . . . . . . . . . . . . . . . . . . . . V1-T5-77 Meter Socket Accessories . . . . . . . . . . . . . . . . . . . . V1-T5-30 Metering Stack Accessories, Group Metering . . . . . . . . V1-T5-136, V1-T5-137, V1-T5-139 West Coast All-In-One Design Accessories, Meter Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-60 Mobile Home Panels. . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-23 Direct Feed Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-23 Padmount Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-23 Pedestal Extension . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-23 StructuredWiringSolutions Patch Cords. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-21 Surge Protection Devices and Lightning Arresters 3-Pack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T2-6 Flushmount Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T2-6 Outdoor Communication Grounding Device . . . . . . . . V1-T2-6 Quick Connect Design . . . . . . . . . . . . . . . . . . . . . . . . V1-T2-6 Raintight Enclosure . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T2-6 Temporary Power/RV Park Cable TV and Telephone Bracket . . . . . . . . . . . . . . . . V1-T6-7 Fluorescent Light Kit . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-7 Pad-Mount Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-7 Pedestal Extension . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-7 Rainproof Conduit Hub . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-7 Renewal Parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-8 Type BR Loadcenters and Circuit Breakers . . . . . . . . . V1-T1-60 Alarm Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-85 Auxiliary Contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-85 Field Installation and Parts . . . . . . . . . . . . . . . . . . . . V1-T1-60 Filler Plates . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-60 Ground Bar Kits. . . . . . . . . . . . . . . . . . . . . V1-T1-65, V1-T1-92 Handle Lockoffs . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-84 Handle Ties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-84 Hold-Down Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-84 Main and Sub-Feed Lug Blocks . . . . . . . . . . . . . . . . V1-T1-60 Main Breaker Lug Kits. . . . . . . . . . . . . . . . . . . . . . . . V1-T1-84 Main Lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-60 Mechanical Interlock Covers. . . . . . . . . . . . . . . . . . . V1-T1-63 Mechanical Interlocks . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-85 Rainproof Conduit Hubs . . . . . . . . . . . . . . . . . . . . . . V1-T1-65 Shunt Trip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-85 Type CH Loadcenters and Circuit Breakers . . . . . . . . . V1-T1-22 Decorator Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-26 Field Installation and Parts . . . . . . . . . . . . . . . . . . . . V1-T1-22 Goof Collars . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-26 Ground Bar Kits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-25 Handle Lockdogs . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-38 Handle Lockoffs . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-38 Handle Ties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-38 Hold-Down Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-38 Main Breaker Lug Kits. . . . . . . . . . . . . . . . . . . . . . . . V1-T1-38 Mechanical Interlock Covers. . . . . . . . . . . . . . . . . . . V1-T1-23 Mechanical Interlocks . . . . . . . . . . . . . . . . V1-T1-23, V1-T1-38 Mounting Bases . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-38 Neutral Bar Accessories . . . . . . . . . . . . . . . . . . . . . . V1-T1-25 Phase Adapters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-25 Rainproof Conduit Hubs . . . . . . . . . . . . . . . . . . . . . . V1-T1-25 Shunt Trip . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-39 Admiral—SS Marina Power and Lighting Equipment Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-62 Air Conditioning Disconnects. . . . . . . . . . . . . . . . . V1-T7-1–V1-T7-10 Cross-Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T7-6 Ground Fault Receptacle . . . . . . . . . . . . . . . . . . . . . . . . V1-T7-5 Molded Case Switch . . . . . . . . . . . . . . . . . . . . V1-T7-2, V1-T7-4 Pullouts Fused . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T7-2, V1-T7-4 Volume 1—Residential and Light Commercial CA08100002E—April 2014 www.eaton.com V1-A3-1 Appendix 3—Alphabetical Product Index Non-Fused . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T7-2, V1-T7-4 Air Cooled Generators Standby Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T3-3 Air Cooled Standby Standby Generator System . . . . . . . . . . . . . . . . . . . . . . V1-T3-2 Alarm Contacts Type BR Loadcenters and Circuit Breakers Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-85 Aluminum Meter Breakers Metering Products Meter Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-87 ATS Kit Automatic Transfer Switches . . . . . . . . . . . . . . . . . . . V1-T3-14 ATS Ready LC with factory-installed ATS kit Automatic Transfer Switches . . . . . . . . . . . . . . . . . . . V1-T3-14 Breaker Plate Marina Power and Lighting Equipment/RV Park Hook-Ups Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75 Bus Bar Assembly Marina Power and Lighting Equipment/RV Park Hook-Ups Accessories. . . . . . . . . . . . . . . . . . . . . . . . V1-T6-76, V1-T6-77 C Cable TV and Telephone Bracket Temporary Power/RV Park Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-7 Camera with IR Emitters StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . . V1-T4-9 CAT6 Inserts StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-20 ATS Ready Loadcenter Automatic Transfer Switches . . . . . . . . . . . . . . . . . . . V1-T3-14 CH Circuit Breakers Type CH Loadcenters and Circuit Breakers . . . . . . . . . . . . . . . V1-T1-31 Audio Distribution Module, A-BUS Products StructuredWiringSolutions . . . . . . . . . . . . . . . . . . . . . V1-T4-11 CH Specialty Products Non-Metallic Loadcenter . . . . . . . . . . . . . . . . . . . . . . . V1-T1-21 Audio Kit, A-BUS Products StructuredWiringSolutions . . . . . . . . . . . . . . . . . . . . . V1-T4-11 CH Style Renovation Solutions Metering Products Meter Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-86 Audio Module, A-BUS Products StructuredWiringSolutions . . . . . . . . . . . . . . . . . . . . . V1-T4-11 Audio System Components StructuredWiringSolutions Dual Voice Coil Speaker . . . . . . . . . . . . . . . . . . . . . . In-Wall Speakers. . . . . . . . . . . . . . . . . . . . . . . . . . . . Outdoor Speakers . . . . . . . . . . . . . . . . . . . . . . . . . . Rough-In Ring. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Round Ceiling Speakers . . . . . . . . . . . . . . . . . . . . . . Volume Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-10 V1-T4-10 V1-T4-10 V1-T4-10 V1-T4-10 V1-T4-10 Automatic Transfer Switches . . . . . . . . . . . . . . . V1-T3-11–V1-T3-15 ATS Ready LC with factory-installed ATS kit. . . . . . . . V1-T3-14 ATS Ready Loadcenter . . . . . . . . . . . . . . . . . . . . . . . . V1-T3-14 ATS Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T3-14 Eaton’s Green Line . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T3-11 Fully Automatic Transfer Switches . . . . . . . . . . . . . . . V1-T3-11 Auxiliary Contact Type BR Loadcenters and Circuit Breakers Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-85 Circuit Breakers Marina Power and Lighting Equipment/RV Park Hook-Ups Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75 Clear Plastic Covers StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-17 Coax Video Modules StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . . V1-T4-5 Combination Modules StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . . V1-T4-7 Commercial Lever Bypass Sockets Metering Products . . . . . . . . . . . . . . . . . . . . V1-T5-10–V1-T5-17 Commercial Meter Stack Modules Group Metering Metering Products . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-127 Commercial Safety Sockets Meter Breakers Metering Products . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-83 B Blank Filler Modules StructuredWiringSolutions . . . . . . . . . . . . . . . . . . . . . . V1-T4-8 Blank Inserts StructuredWiringSolutions . . . . . . . . . . . . . . . . . . . . . V1-T4-20 Blank Oversized Wall Plates StructuredWiringSolutions . . . . . . . . . . . . . . . . . . . . . V1-T4-19 Blank Receptacle Wall Plates StructuredWiringSolutions . . . . . . . . . . . . . . . . . . . . . V1-T4-19 BR Circuit Breakers BR Specialty Products Type BR Loadcenters and Circuit Breakers . . . . . . . . . . . . . V1-T1-75 V1-A3-2 Circuit Breaker Unit Enclosures Type CH Loadcenters and Circuit Breakers . . . . . . . . . . . . . . . V1-T1-94 Volume 1—Residential and Light Commercial Common Trip Quadplex Breakers Type BR Loadcenters and Circuit Breakers . . . . . . . . . . . . . . . V1-T1-82 Communications Grounding Device Metering Products . . . . . . . . . . . . . . . . . . . . V1-T5-35, V1-T5-36 Convertible Loadcenters MCB Type BR Loadcenters and Circuit Breakers . . . . . . . . . . . . . . . V1-T1-51 Type CH Loadcenters and Circuit Breakers . . . . . . . . . . . . . . . V1-T1-11 Convertible Loadcenters MLO Type BR CA08100002E—April 2014 www.eaton.com Appendix 3—Alphabetical Product Index Loadcenters and Circuit Breakers . . . . . . . . . . . . . . V1-T1-51 Type CH Loadcenters and Circuit Breakers . . . . . . . . . . . . . . V1-T1-11 D-Marc Box Enclosures StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-15 Cover Plate, A-BUS Products StructuredWiringSolutions . . . . . . . . . . . . . . . . . . . . . V1-T4-13 Dome Camera StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . . V1-T4-9 Cover Set Marina Power and Lighting Equipment/RV Park Hook-Ups Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75 Door Hasp Marina Power and Lighting Equipment/RV Park Hook-Ups Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-77 Covers StructuredWiringSolutions Clear Plastic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-17 Hinged . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-16 Metal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-15 Door Station, A-BUS Products StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-13 Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-50 DSL or Cable Router StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . . V1-T4-9 Cross-Reference Metering Products . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-31 Dual Voice Coil Speaker StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-10 D E Decorator Cover Type CH Loadcenters and Circuit Breakers Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-26 Eaton Terms & Conditions. . . . . . . . . . . . . . . . . . . . . . . . . . . Freight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Limitation of Liability . . . . . . . . . . . . . . . . . . . . . . . . . . . Terms and Conditions of Sale . . . . . . . . . . . . . . . . . . . . Terms of Payment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Digital Electronic Kilowatthour Meters Marina Power and Lighting Equipment Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-81 RV Park Hook-Ups Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-44 Digital Electronic Meters Marina Power and Lighting Equipment/RV Park Hook-Ups Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-76 Direct Feed Kit Mobile Home Panels Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-23 Distribution Equipment—Ground Fault Monitor Marina Power and Lighting Equipment Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-82 Distribution Equipment—MegaYacht Powerpoint Marina Power and Lighting Equipment Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-83 Distribution Equipment—Panels Marina Power and Lighting Equipment Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-89 Power Pedestals RV Park Hook-Ups . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-49 Distribution Equipment—Substations Marina Power and Lighting Equipment Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-86 Distribution Equipment—Transformers Marina Power and Lighting Equipment Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-90 Distribution—Ground Fault Monitor RV Park Hook-Ups Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-45 V1-T1-1 V1-T1-3 V1-T1-5 V1-T1-1 V1-T1-2 V1-T1-3 Eaton’s Green Line Automatic Transfer Switches . . . . . . . . . . . . . . . . . . . V1-T3-11 Emergency Generator Panels Manual Transfer Switches . . . . . . . . . . . . . . V1-T3-16–V1-T3-18 Emergency Power Panels Manual Transfer Switches . . . . . . . . . . . . . . . . . . . . . . V1-T3-16 Enclosed Breakers Loadcenters and Circuit Breakers . . . . . . . . V1-T1-93–V1-T1-95 Enclosures StructuredWiringSolutions D-Marc Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-15 Install Can . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-14 EUSERC Requirements Service Entrance Devices Meter Breakers Metering Products . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-48 External Cover Marina Power and Lighting Equipment/RV Park Hook-Ups Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-76 F Faceplate Marina Power and Lighting Equipment/RV Park Hook-Ups Accessories. . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75–V1-T6-77 Factory-Installed Surge Protection Surge Protection Devices and Lightning Arresters . . . . . . . . . . . . . . . . . . . . V1-T2-2, V1-T2-7 Distribution—Substations RV Park Hook-Ups Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-46 Field Installation and Parts Type BR Loadcenters and Circuit Breakers Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-60 Type CH Loadcenters and Circuit Breakers Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-22 Distribution—Transformers RV Park Hook-Ups Filler Plates Type BR Loadcenters and Circuit Breakers Volume 1—Residential and Light Commercial CA08100002E—April 2014 www.eaton.com V1-A3-3 Appendix 3—Alphabetical Product Index Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-60 H Fire Extinguisher Marina Power and Lighting Equipment/RV Park Hook-Ups Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-77 Handle Lockdogs Type CH Loadcenters and Circuit Breakers Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-38 Firehouse Marina Power and Lighting Equipment Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-73 RV Park Hook-Ups Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-42 Handle Lockoffs Type BR Loadcenters and Circuit Breakers Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-84 Type CH Loadcenters and Circuit Breakers Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-38 Firewall Router Modules StructuredWiringSolutions . . . . . . . . . . . . . . . . . . . . . . V1-T4-8 Fluorescent Light Assembly Marina Power and Lighting Equipment/RV Park Hook-Ups Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75 Handle Ties Accessories Type CH Loadcenters and Circuit Breakers . . . . . . . V1-T1-38 Type BR Loadcenters and Circuit Breakers Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-84 Fluorescent Light Kit Temporary Power/RV Park Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-7 Hatteras Light Marina Power and Lighting Equipment Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-69 Flush Flange Kit Manual Transfer Switches . . . . . . . . . . . . . . . . . . . . . V1-T3-18 Flushmount Kit Surge Protection Devices and Lightning Arresters . . . . V1-T2-6 Fully Automatic Transfer Switches Automatic Transfer Switches . . . . . . . . . . . . . . . . . . . V1-T3-11 Fuse Holder Marina Power and Lighting Equipment/RV Park Hook-Ups Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-76 Hinged Covers StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-16 Hold-Down Kits Type BR Loadcenters and Circuit Breakers Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-84 Hose and Cable Brackets Marina Power and Lighting Equipment/RV Park Hook-Ups Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75 Fused, Unfused and Molded Case Switch Air Conditioning Disconnects . . . . . . . . . . . . V1-T7-2–V1-T7-10 House Panels Meter Breakers Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-77 Metering Products . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-75 G I Goof Collars Type CH Loadcenters and Circuit Breakers Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-26 Ground Bar Kits Type BR Loadcenters and Circuit Breakers Accessories . . . . . . . . . . . . . . . . . . . . . . . V1-T1-65, V1-T1-92 Type CH Loadcenters and Circuit Breakers Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-25 Inserts StructuredWiringSolutions Blank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CAT5e . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CAT6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RG6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RJ11 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . RJ45, CAT5e . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ground Fault Receptacle Air Conditioning Disconnects . . . . . . . . . . . . . . . . . . . . V1-T7-5 Install Can Enclosures StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-14 Group Metering Metering Products . . . . . . . . . . . . . . . . . . V1-T5-88–V1-T5-147 Accessories . . . . . . . . . . . . . . . . . . . . . V1-T5-136, V1-T5-139 Commercial Meter Stack Modules. . . . . . . . . . . . . V1-T5-127 Main Service Modules . . . . . . . . . . . . . . . . . . . . . . V1-T5-101 Main Tenant Circuit Breaker . . . . . . V1-T5-96, V1-T5-98, V1-T5-125, V1-T5-134 Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-90 Phase Balanced Stack . . . . . . . . . . . . . . . . . . . . . . V1-T5-126 Renewal Parts . . . . . . . . . . . . . . . . . . . V1-T5-138, V1-T5-140 Residential and Commercial Applications . . . . . . . . V1-T5-88 Residential Meter Stacks . . . . . . . . . . . . . . . . . . . . V1-T5-116 Surge Metering . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-115 Type CCV Tenant Main Circuit Breaker . . . . . . . . . . V1-T5-95 Instrument Rated Sockets Metering Products . . . . . . . . . . . . . . . . . . . . V1-T5-25, V1-T5-26 V1-A3-4 Volume 1—Residential and Light Commercial V1-T4-20 V1-T4-20 V1-T4-20 V1-T4-20 V1-T4-20 V1-T4-20 Intercom Kit, A-BUS Products StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-13 Intercom Module, A-BUS Products StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-12 Interface Unit, A-BUS Products StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-12 In-Wall Speakers StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-10 IR Emitter, A-BUS Products StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-12 CA08100002E—April 2014 www.eaton.com Appendix 3—Alphabetical Product Index Isolation Plate Marina Power and Lighting Equipment/RV Park Hook-Ups Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75 CH Specialty Products Non-Metallic Loadcenter . . . . . . . . . . . . . . . . . . . . V1-T1-21 Plug-On Neutral Loadcenter . . . . . . . . . . . . . . . . . . V1-T1-17 Spa Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-14 Surge Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-15 Type CH Renovation Loadcenter . . . . . . . . . . . . . . V1-T1-18 Type CH Retrofit Interior Kits . . . . . . . . . . . . . . . . . V1-T1-19 Circuit Breaker Unit Enclosures . . . . . . . . . . . . . . . . V1-T1-94 Convertible Loadcenters MCB . . . . . . . . . . . . . . . . . V1-T1-11 Convertible Loadcenters MLO . . . . . . . . . . . . . . . . . V1-T1-11 Single-Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-7 Three-Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-12 K Keypad, A-BUS Products StructuredWiringSolutions . . . . . . . . . . . . . . . . . . . . . V1-T4-12 L Lens Marina Power and Lighting Equipment/RV Park Hook-Ups Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-77 Life Ring Marina Power and Lighting Equipment/RV Park Hook-Ups Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-77 Local Input Plate, A-BUS Products StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-11 M Light and Lens Assembly Marina Power and Lighting Equipment/RV Park Hook-Ups Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75 Main and Sub-Feed Lug Blocks Type BR Loadcenters and Circuit Breakers Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-60 Light Fuse Marina Power and Lighting Equipment/RV Park Hook-Ups Accessories . . . . . . . . . . . . . . . . . . . . . . . V1-T6-76, V1-T6-77 Main Breaker Lug Kits Type BR Loadcenters and Circuit Breakers Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-84 Type CH Loadcenters and Circuit Breakers Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-38 Light Holder Marina Power and Lighting Equipment/RV Park Hook-Ups Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-77 Lighthouse Marina Power and Lighting Equipment Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-54 Lighthouse—SS Marina Power and Lighting Equipment Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-58 Liquid Cooled Generator Standby Generator . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T3-4 Liquid Cooled Standby Standby Generator System . . . . . . . . . . . . . . . . . . . . . . V1-T3-2 Loadcenter Interiors/OEM Loadcenters Loadcenters and Circuit Breakers . . . . . . . . V1-T1-88–V1-T1-92 Loadcenters and Circuit Breakers . . . . . . . . . . . . . V1-T1-1–V1-T1-95 Enclosed Breakers . . . . . . . . . . . . . . . . . . . V1-T1-93–V1-T1-95 Loadcenter Interiors/OEM Loadcenters . . . V1-T1-88–V1-T1-92 Type BR . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-42–V1-T1-69 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-60 BR Specialty Products BR Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-75 Riser Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-58 Spa Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-57 Type BR Renovation Loadcenter . . . . . . . . . . . . . . V1-T1-59 Type BR Retrofit Interior Kits. . . . . . . . . . . . . . . . . V1-T1-72 Common Trip Quadplex Breakers . . . . . . . . . . . . . . V1-T1-82 Convertible Loadcenters MCB . . . . . . . . . . . . . . . . . V1-T1-51 Convertible Loadcenters MLO . . . . . . . . . . . . . . . . . V1-T1-51 Plug-On Circuit Breakers . . . . . . . . . . . . . . . . . . . . . V1-T1-75 Quick-Pro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-59 Single-Phase. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-48 Three-Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-54 Type CH . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-2–V1-T1-28 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-22 CH Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-31 Main Door Marina Power and Lighting Equipment/RV Park Hook-Ups Accessories. . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75, V1-T6-77 Main Housing Marina Power and Lighting Equipment/RV Park Hook-Ups Accessories. . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75–V1-T6-77 Main Lugs Type BR Loadcenters and Circuit Breakers Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-60 Main Service Modules Group Metering Metering Products . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-101 Main Tenant Circuit Breaker Group Metering Metering Products . . . . . . V1-T5-96, V1-T5-98, V1-T5-125, V1-T5-134 Manual Transfer Switches . . . . . . . . . . . . . . . . . . V1-T3-16–V1-T3-19 Emergency Generator Panels . . . . . . . . . . . . . . . . . . . V1-T3-16 Emergency Power Panels . . . . . . . . . . . . . . . . . . . . . . V1-T3-16 Generator Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T3-18 Indoor and Outdoor Designs. . . . . . . . . . . . . . . . . . . V1-T3-17 Indoor and Outdoor Designs . . . . . . . . . . . . . . . . . . . . V1-T3-16 Standard Manual Transfer Switch . . . . . . . . . . . . . . . . V1-T3-18 Switched Neutral Manual Transfer Switch . . . . . . . . . V1-T3-18 Marina Power and Lighting Equipment Power Pedestals . . . . . . . . . . . . . . V1-T6-2, V1-T6-51–V1-T6-90 Admiral—SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-62 Digital Electronic Kilowatthour Meters . . . . . . . . . . . V1-T6-81 Distribution Equipment—Ground Fault Monitor . . . . V1-T6-82 Distribution Equipment—MegaYacht Powerpoint . . V1-T6-83 Distribution Equipment—Panels . . . . . . . . . . . . . . . . V1-T6-89 Distribution Equipment—Substations. . . . . . . . . . . . V1-T6-86 Distribution Equipment—Transformers . . . . . . . . . . V1-T6-90 Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-73 Volume 1—Residential and Light Commercial CA08100002E—April 2014 www.eaton.com V1-A3-5 Appendix 3—Alphabetical Product Index Hatteras Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Lighthouse—SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mariner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Newport Harbor Mate . . . . . . . . . . . . . . . . . . . . . . . Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-69 V1-T6-54 V1-T6-58 V1-T6-80 V1-T6-65 V1-T6-79 Marina Power and Lighting Equipment/RV Park Hook-Ups Power Pedestals Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75 Mariner Marina Power and Lighting Equipment Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-80 Mechanical Interlock Cover Metering Products Meter Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-65 Mechanical Interlock Covers Type BR Loadcenters and Circuit Breakers Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-63 Type CH Loadcenters and Circuit Breakers Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-23 Mechanical Interlocks Type BR Loadcenters and Circuit Breakers Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-85 Type CH Loadcenters and Circuit Breakers Accessories . . . . . . . . . . . . . . . . . . . . . . . V1-T1-23, V1-T1-38 Mechanical Lugs Metering Products . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-34 Metal Covers StructuredWiringSolutions . . . . . . . . . . . . . . . . . . . . . V1-T4-15 Meter Breakers Metering Products . . . . . . . . . . . . . . . . . . . V1-T5-37–V1-T5-87 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-77 Aluminum Meter Breakers . . . . . . . . . . . . . . . . . . . . V1-T5-87 CH Style Renovation Solutions. . . . . . . . . . . . . . . . . V1-T5-86 Commercial Safety Sockets . . . . . . . . . . . . . . . . . . . V1-T5-83 EUSERC Requirements Service Entrance Devices . V1-T5-48 House Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-75 Mechanical Interlock Cover . . . . . . . . . . . . . . . . . . . V1-T5-65 Non-EUSERC Combination Service Entrance Devices. . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-39 Residential Meter Breakers . . . . . . . . . . . . . . . . . . . V1-T5-37 West Coast All-In-One Design . . . . . . . . . . . . . . . . . V1-T5-59 Meter Packs Group Metering Metering Products . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-90 Metering Products . . . . . . . . . . . . . . . . . . . . . . . V1-T5-1–V1-T5-147 Commercial Lever Bypass Sockets. . . . . . . V1-T5-10–V1-T5-17 Communications Grounding Device . . . . . . V1-T5-35, V1-T5-36 Cross-Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-31 Group Metering. . . . . . . . . . . . . . . . . . . . . V1-T5-88–V1-T5-147 Accessories . . . . . . . . . . . . V1-T5-136, V1-T5-137, V1-T5-139 Commercial Meter Stack Modules. . . . . . . . . . . . . V1-T5-127 Main Service Modules . . . . . . . . . . . . . . . . . . . . . . V1-T5-101 Main Tenant Circuit Breaker . . . . . . V1-T5-96, V1-T5-98, V1-T5-125, V1-T5-134 Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-90 Phase Balanced Stack . . . . . . . . . . . . . . . . . . . . . . V1-T5-126 Renewal Parts . . . . . . . . . . . . . . . . . . . V1-T5-138, V1-T5-140 V1-A3-6 Volume 1—Residential and Light Commercial Residential and Commercial Applications . . . . . . . . . V1-T5-88 Residential Meter Stacks . . . . . . . . . . . . . . . . . . . . V1-T5-116 Surge Metering . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-115 Type CCV Tenant Main Circuit Breaker. . . . . . . . . . . V1-T5-95 Instrument Rated Sockets . . . . . . . . . . . . . . V1-T5-25, V1-T5-26 Mechanical Lugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-34 Meter Breakers . . . . . . . . . . . . . . . . . . . . . . V1-T5-37–V1-T5-87 Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-77 Aluminum Meter Breakers . . . . . . . . . . . . . . . . . . . . V1-T5-87 CH Style Renovation Solutions . . . . . . . . . . . . . . . . . V1-T5-86 Commercial Safety Sockets . . . . . . . . . . . . . . . . . . . V1-T5-83 EUSERC Requirements Service Entrance Devices. . V1-T5-48 House Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-75 Mechanical Interlock Cover. . . . . . . . . . . . . . . . . . . . V1-T5-65 Non-EUSERC Combination Service Entrance Devices . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-39 Residential Meter Breakers . . . . . . . . . . . . . . . . . . . V1-T5-37 West Coast All-In-One Design . . . . . . . . . . . . . . . . . V1-T5-59 Meter Socket Accessories Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-30 Multiple Position Horizontal Ganged Sockets . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-18–V1-T5-24 Residential Pedestals. . . . . . . . . . . . . . . . . . V1-T5-27, V1-T5-28 Single Meter Sockets . . . . . . . . . . . . . . . . . . . V1-T5-2–V1-T5-9 Residential Ringless Type Cover. . . . . . . . . . . . . . . . . V1-T5-4 Mini Digital Cable, Patch Cords StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-21 Mobile Home Panels Accessories Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-23 Power Pedestals . . . . . . . . . . . . . . V1-T6-2, V1-T6-21–V1-T6-27 Modulator Modules StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . . V1-T4-8 Modules StructuredWiringSolutions Blank Filler. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Camera with IR Emitters. . . . . . . . . . . . . . . . . . . . . . . Dome Camera . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DSL or Cable Router . . . . . . . . . . . . . . . . . . . . . . . . . . Firewall Router . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Modulator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mounting Shelf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mounting Shelf Cover . . . . . . . . . . . . . . . . . . . . . . . . . Patch . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product Shelf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Service Shelf . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Standalone . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Video Processor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-8 V1-T4-9 V1-T4-9 V1-T4-9 V1-T4-8 V1-T4-8 V1-T4-9 V1-T4-9 V1-T4-8 V1-T4-9 V1-T4-9 V1-T4-8 V1-T4-9 Molded Case Switch Air Conditioning Disconnects. . . . . . . . . . . . . . V1-T7-2, V1-T7-4 Mounting Bases Type CH Loadcenters and Circuit Breakers Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-38 Mounting Brackets Marina Power and Lighting Equipment/RV Park Hook-Ups Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-77 CA08100002E—April 2014 www.eaton.com Appendix 3—Alphabetical Product Index Mounting Feet Marina Power and Lighting Equipment/RV Park Hook-Ups Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-76 Mounting Shelf StructuredWiringSolutions . . . . . . . . . . . . . . . . . . . . . . V1-T4-9 Mounting Shelf Cover StructuredWiringSolutions . . . . . . . . . . . . . . . . . . . . . . V1-T4-9 Multiple Position Horizontal Ganged Sockets Metering Products . . . . . . . . . . . . . . . . . . . V1-T5-18–V1-T5-24 Temporary Power/RV Park Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-7 Pedestal Units Temporary Power/RV Park Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-16 Phase Adapters Type CH Loadcenters and Circuit Breakers Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-25 N Phase Balanced Stack Group Metering Metering Products . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-126 Neutral Bar Accessories Type CH Loadcenters and Circuit Breakers Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-25 Phone, Cable, Internet Assemblies Marina Power and Lighting Equipment/RV Park Hook-Ups Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-76 Newport Camp Mate Power Pedestal RV Park Hook-Ups Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-36 Plug-On Circuit Breakers Type BR Loadcenters and Circuit Breakers . . . . . . . . . . . . . . . V1-T1-75 Newport Harbor Mate Marina Power and Lighting Equipment Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-65 Plug-On Neutral Loadcenter CH Specialty Products Type CH Loadcenters and Circuit Breakers . . . . . . . . . . . . . V1-T1-17 Non-EUSERC Combination Service Entrance Devices Metering Products Meter Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-39 Plug-On Surge Protection Surge Protection Devices and Lightning Arrester . . . . . V1-T2-3 Non-Metallic Loadcenter CH Specialty Products Type CH Loadcenters and Circuit Breakers . . . . . . . . . . . . . V1-T1-21 O Outdoor Communication Grounding Device Surge Protection Devices and Lightning Arresters . . . . V1-T2-6 Outdoor Speakers StructuredWiringSolutions . . . . . . . . . . . . . . . . . . . . . V1-T4-10 P Packaged Products StructuredWiringSolutions . . . . . . . . . . . . . . . . . . . . . . V1-T4-4 Padmount Adapter Mobile Home Panels Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-23 Pad-Mount Bracket Temporary Power/RV Park Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-7 Park Light Power Pedestal RV Park Hook-Ups Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-39 Patch Cords StructuredWiringSolutions Mini Digital Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-21 Telephone. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-21 Patch Modules StructuredWiringSolutions . . . . . . . . . . . . . . . . . . . . . . V1-T4-8 Pedestal Extension Mobile Home Panels Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-23 Portable Generators Residential Standby Backup Power Solutions . . . . . . . . . . . . . . . . . . . . . V1-T3-7–V1-T3-10 Power Inlet Box Manual Transfer Switches . . . . . . . . . . . . . . . . . . . . . . V1-T3-18 Power Outlet Panels Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-2 Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-1–V1-T6-90 Marina Power and Lighting Equipment. . . . . . . . . . . . . . . . . . V1-T6-2, V1-T6-51–V1-T6-90 Admiral—SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-62 Digital Electronic Kilowatthour Meters . . . . . . . . . . . V1-T6-81 Distribution Equipment—Ground Fault Monitor . . . . V1-T6-82 Distribution Equipment—MegaYacht Powerpoint . . V1-T6-83 Distribution Equipment—Panels . . . . . . . . . . . . . . . . V1-T6-89 Distribution Equipment—Substations. . . . . . . . . . . . V1-T6-86 Distribution Equipment—Transformers . . . . . . . . . . V1-T6-90 Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-73 Hatteras Light . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-69 Lighthouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-54 Lighthouse—SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-58 Mariner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-80 Newport Harbor Mate. . . . . . . . . . . . . . . . . . . . . . . . V1-T6-65 Smart Start . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-79 Marina Power and Lighting Equipment/RV Park Hook-Ups Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75 Mobile Home Panels . . . . . . . . . . . V1-T6-2, V1-T6-21–V1-T6-27 Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-23 Power Outlet Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-2 RV Park Hook-Ups . . . . . . . . . . . . . . . . . . . . V1-T6-28–V1-T6-50 Digital Electronic Kilowatthour Meters . . . . . . . . . . . V1-T6-44 Distribution Equipment—Panels . . . . . . . . . . . . . . . . V1-T6-49 Distribution—Ground Fault Monitor . . . . . . . . . . . . . V1-T6-45 Distribution—Substations . . . . . . . . . . . . . . . . . . . . . V1-T6-46 Distribution—Transformers. . . . . . . . . . . . . . . . . . . . V1-T6-50 Volume 1—Residential and Light Commercial CA08100002E—April 2014 www.eaton.com V1-A3-7 Appendix 3—Alphabetical Product Index Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-42 Newport Camp Mate Power Pedestal . . . . . . . . . . . V1-T6-36 Park Light Power Pedestal . . . . . . . . . . . . . . . . . . . . V1-T6-39 Powerhouse Power Pedestal . . . . . . . . . . . . . . . . . . V1-T6-30 Powerhouse Stainless Steel Power Pedestal. . . . . . V1-T6-33 Temporary Power/RV Park . . . . . . . . . . . . . . V1-T6-3–V1-T6-20 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-7 Pedestal Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-16 Surface Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-10 Powerhouse Power Pedestal RV Park Hook-Ups Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-30 Powerhouse Stainless Steel Power Pedestal RV Park Hook-Ups Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-33 Product Shelf StructuredWiringSolutions . . . . . . . . . . . . . . . . . . . . . . V1-T4-9 Pullouts, Fused and Non-Fused Air Conditioning Disconnects . . . . . . . . . . . . . V1-T7-2, V1-T7-4 Metering Products . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-116 Residential Pedestals Metering Products . . . . . . . . . . . . . . . . . . . . V1-T5-27, V1-T5-28 Residential Ringless Type Cover Single Meter Sockets Metering Products . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-4 Residential Standby Backup Power Solutions . . . . V1-T3-1–V1-T3-15 Automatic Transfer Switches . . . . . . . . . . . V1-T3-11–V1-T3-15 Manual Transfer Switches . . . . . . . . . . . . . . V1-T3-16–V1-T3-19 Portable Generators. . . . . . . . . . . . . . . . . . . . V1-T3-7–V1-T3-10 Standby Generator. . . . . . . . . . . . . . . . . . . . . . V1-T3-2–V1-T3-6 RG6 Inserts StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-20 Riser Panel BR Specialty Products Type BR Loadcenters and Circuit Breakers . . . . . . . . . . . . . V1-T1-58 RJ11 Inserts StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-20 RJ45, CAT5e Inserts StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-20 Q Quick Connect Design Surge Protection Devices and Lightning Arresters . . . . V1-T2-6 Quick-Pro Type BR Loadcenters and Circuit Breakers . . . . . . . . . . . . . . V1-T1-59 R Rainproof Conduit Hub Temporary Power/RV Park Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-7 Rainproof Conduit Hubs Type BR Loadcenters and Circuit Breakers Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-65 Type CH Loadcenters and Circuit Breakers Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-25 Raintight Enclosure Surge Protection Devices and Lightning Arresters . . . . V1-T2-6 Receptacles Marina Power and Lighting Equipment/RV Park Hook-Ups Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75 Remote Controls, A-BUS Products StructuredWiringSolutions . . . . . . . . . . . . . . . . . . . . . V1-T4-12 Renewal Parts Group Metering Metering Products . . . . . . . . . . . . . . . . V1-T5-138, V1-T5-140 Temporary Power/RV Park Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-8 Rough-In Ring StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-10 Round Ceiling Speakers StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-10 RV Park Hook-Ups Power Pedestals . . . . . . . . . . . . . . . . . . . . . V1-T6-28–V1-T6-50 Digital Electronic Kilowatthour Meters . . . . . . . . . . . V1-T6-44 Distribution Equipment—Panels . . . . . . . . . . . . . . . . V1-T6-49 Distribution—Ground Fault Monitor . . . . . . . . . . . . . V1-T6-45 Distribution—Substations . . . . . . . . . . . . . . . . . . . . . V1-T6-46 Distribution—Transformers. . . . . . . . . . . . . . . . . . . . V1-T6-50 Firehouse . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-42 Newport Camp Mate Power Pedestal . . . . . . . . . . . V1-T6-36 Park Light Power Pedestal . . . . . . . . . . . . . . . . . . . . V1-T6-39 Powerhouse Power Pedestal . . . . . . . . . . . . . . . . . . V1-T6-30 Powerhouse Stainless Steel Power Pedestal . . . . . . V1-T6-33 S Safety Sockets, Commercial Meter Breakers Metering Products . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-83 Service Entrance Surge Protection Surge Protection Devices and Lightning Arresters . . . . V1-T2-2 Service Shelf StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . . V1-T4-9 Residential and Commercial Applications Group Metering Metering Products . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-88 Shunt Trip Type BR Loadcenters and Circuit Breakers Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-85 Type CH Loadcenters and Circuit Breakers Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-39 Residential Meter Breakers Meter Breakers Metering Products . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-37 Single Meter Sockets Metering Products . . . . . . . . . . . . . . . . . . . . . . V1-T5-2–V1-T5-9 Residential Ringless Type Cover. . . . . . . . . . . . . . . . . V1-T5-4 Residential Meter Stacks Group Metering Single-Phase Type BR V1-A3-8 Volume 1—Residential and Light Commercial CA08100002E—April 2014 www.eaton.com Appendix 3—Alphabetical Product Index Loadcenters and Circuit Breakers . . . . . . . . . . . . . . V1-T1-48 Type CH Loadcenters and Circuit Breakers . . . . . . . . . . . . . . . V1-T1-7 Smart Start Marina Power and Lighting Equipment Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-79 Spa Panels BR Specialty Products Type BR Loadcenters and Circuit Breakers . . . . . . . . . . . . . V1-T1-57 CH Specialty Products Type CH Loadcenters and Circuit Breakers . . . . . . . . . . . . . V1-T1-14 Type BR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-57 Spring Closure Marina Power and Lighting Equipment/RV Park Hook-Ups Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-75 Standalone Modules StructuredWiringSolutions . . . . . . . . . . . . . . . . . . . . . . V1-T4-8 Standard Manual Transfer Switch Manual Transfer Switches . . . . . . . . . . . . . . . . . . . . . V1-T3-18 Standby Generator . . . . . . . . . . . . . . . . . . . . . . . . . V1-T3-2–V1-T3-6 Air Cooled Generators. . . . . . . . . . . . . . . . . . . . . . . . . . V1-T3-3 Liquid Cooled Generators . . . . . . . . . . . . . . . . . . . . . . . V1-T3-4 Standby Generator System Air Cooled Standby . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T3-2 Liquid Cooled Standby . . . . . . . . . . . . . . . . . . . . . . . . . V1-T3-2 Strobe Light Marina Power and Lighting Equipment/RV Park Hook-Ups Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-77 Structured Wiring . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-1–V1-T4-22 StructuredWiringSolutions . . . . . . . . . . . . . . . . . . V1-T4-2–V1-T4-22 A-BUS Products . . . . . . . . . . . . . . . . . . . . . V1-T4-11–V1-T4-13 Audio System Components . . . . . . . . . . . . . . . . . . . . V1-T4-10 Combination Modules . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-7 Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-15–V1-T4-17 Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-14, V1-T4-15 Inserts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-20 Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-8, V1-T4-9 Packaged Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-4 Patch Cords. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-21 Telephone Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-6 Video Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-5 Wall Plates . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-18, V1-T4-19 Surface Units Temporary Power/RV Park Power Pedestals . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-10 Surge Installed Loadcenters Surge Protection Devices and Lightning Arrester . . . . . V1-T2-7 Surge Metering Group Metering Metering Products . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-115 Surge Panel CH Specialty Products Type CH Loadcenters and Circuit Breakers . . . . . . . . . . . . . V1-T1-15 Surge Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T2-1–V1-T2-8 Factory-Installed Surge Protection. . . . . . . . . . V1-T2-2, V1-T2-7 Plug-On Surge Protection . . . . . . . . . . . . . . . . . . . . . . . V1-T2-3 Type 3 Point-of-Use Surge Protection. . . . . . . . . . . . . V1-T2-3 Type BRSURGE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T2-3 Type BRSURGECSA . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T2-3 Type CHQSA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T2-3 Type CHSA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T2-3 Service Entrance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T2-2 Surge Installed Loadcenters . . . . . . . . . . . . . . . . . . . . . V1-T2-7 Surge Protection Devices and Lightning Arresters . . . . . . . . . . . . . . . . . . . . V1-T2-2–V1-T2-8 Surge Ready Loadcenter . . . . . . . . . . . . . . . . . V1-T2-2, V1-T2-7 Two-Stage Protection . . . . . . . . . . . . . . . . . . . V1-T2-2, V1-T2-3 UL 1449 3rd Edition Surge Protection Type 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T2-2 Type 1 CHSP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T2-4 Type 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T2-2 Type 2 Plug-On . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T2-8 UL 1449 3rd Edition, cUL Type 2 CHSP Service Entrance. . . . . . . . . . . . . . . . . . V1-T2-5 Surge Protection Devices and Lightning Arresters . . . . . . . . . . . . . . . . . . . . . . . . V1-T2-2–V1-T2-8 Surge Ready Type CH Loadcenters and Circuit Breakers . . . . . . . . . . . . . . . V1-T1-16 Surge Ready Loadcenter . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T2-7 Surge Protection Devices and Lightning Arresters . . . . V1-T2-2 Switched Neutral Manual Transfer Switch Manual Transfer Switches . . . . . . . . . . . . . . . . . . . . . . V1-T3-18 T Telephone Modules StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . . V1-T4-6 Telephone Patch Cords StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-21 Temporary Power/RV Park Power Pedestals . . . . . . . . . . . . . . . . . . . . . . V1-T6-3–V1-T6-20 Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-7 Pedestal Units. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-16 Surface Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-10 Three-Phase Type BR Loadcenters and Circuit Breakers . . . . . . . . . . . . . . . V1-T1-54 Type CH Loadcenters and Circuit Breakers . . . . . . . . . . . . . . . V1-T1-12 Transfer Panels Manual Transfer Switches . . . . . . . . . . . . . . . . . . . . . . V1-T3-16 Two-Stage Protection Surge Protection Devices and Lightning Arresters . . . . . . . . . . . . . . . . . . . . V1-T2-2, V1-T2-3 Type 1 Surge Protective Device Surge Protection Devices and Lightning Arresters . . . . V1-T2-2 Type 2 Surge Protective Device Surge Protection Devices and Lightning Arresters . . . . V1-T2-2 Type 3 Point-of-Use Surge Protection Surge Protection Devices and Lightning Arresters . . . . V1-T2-3 Volume 1—Residential and Light Commercial CA08100002E—April 2014 www.eaton.com V1-A3-9 Appendix 3—Alphabetical Product Index Type BR Loadcenters and Circuit Breakers . . . . . . . . V1-T1-42–V1-T1-69 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-60 BR Specialty Products BR Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-75 Riser Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-58 Spa Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-57 Type BR Renovation Loadcenter . . . . . . . . . . . . . . V1-T1-59 Type BR Retrofit Interior Kits. . . . . . . . . . . . . . . . . V1-T1-72 Common Trip Quadplex Breakers . . . . . . . . . . . . . . V1-T1-82 Convertible Loadcenters MCB . . . . . . . . . . . . . . . . . V1-T1-51 Convertible Loadcenters MLO . . . . . . . . . . . . . . . . . V1-T1-51 Plug-On Circuit Breakers . . . . . . . . . . . . . . . . . . . . . V1-T1-75 Quick-Pro . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-59 Single-Phase. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-48 Spa Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-57 Three-Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-54 U UL 1449 3rd Edition Surge Protection Devices and Lightning Arrester . . . . . V1-T2-2 V Video Amplifier Power Supply, 110 Volt StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . . V1-T4-5 Video Modules StructuredWiringSolutions Coax Module. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T4-5 Video Amplifier Power Supply, 110 Volt . . . . . . . . . . . V1-T4-5 Video Processor StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . . V1-T4-9 Volume Control StructuredWiringSolutions. . . . . . . . . . . . . . V1-T4-10, V1-T4-11 Type BR Renovation Loadcenter BR Specialty Products Type BR Loadcenters and Circuit Breakers . . . . . . . . . . . . . V1-T1-59 W Type BR Retrofit Interior Kits BR Specialty Products Type BR Loadcenters and Circuit Breakers . . . . . . . . . . . . . V1-T1-72 Wall Outlet Plates StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-18 Type BRSURGE Surge Protection Surge Protection Devices and Lightning Arresters . . . . V1-T2-3 Type CCV Tenant Main Circuit Breaker Group Metering Metering Products . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-95 Type CH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-16 Loadcenters and Circuit Breakers . . . . . . . . . V1-T1-2–V1-T1-28 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-22 CH Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-31 CH Specialty Products Non-Metallic Loadcenter . . . . . . . . . . . . . . . . . . . . V1-T1-21 Plug-On Neutral Loadcenter . . . . . . . . . . . . . . . . . V1-T1-17 Spa Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-14 Surge Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-15 Type CH Renovation Loadcenter . . . . . . . . . . . . . . V1-T1-18 Circuit Breaker Unit Enclosures . . . . . . . . . . . . . . . . V1-T1-94 Convertible Loadcenters MCB . . . . . . . . . . . . . . . . . V1-T1-11 Convertible Loadcenters MLO . . . . . . . . . . . . . . . . . V1-T1-11 Single-Phase. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-7 Surge Ready . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-16 Three-Phase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T1-12 Wall Hanging Outlet Plates StructuredWiringSolutions. . . . . . . . . . . . . . . . . . . . . . V1-T4-18 Wall Plates StructuredWiringSolutions Blank Oversized Plate . . . . . . . . . . . . . . . . . . . . . . . . Blank Receptacle . . . . . . . . . . . . . . . . . . . . . . . . . . . Wall Hanging Outlet . . . . . . . . . . . . . . . . . . . . . . . . . Wall Outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Water Assemblies Marina Power and Lighting Equipment/RV Park Hook-Ups Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T6-76 West Coast All-In-One Design Meter Breakers Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-60 Metering Products . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-59 Numerics 3-Pack Surge Protection Devices and Lightning Arresters . . . . V1-T2-6 Type CH Renovation Loadcenter CH Specialty Products Type CH Loadcenters and Circuit Breakers . . . . . . . . . . . . . V1-T1-18 Type CH Retrofit Interior Kits CH Specialty Products Type CH Loadcenters and Circuit Breakers . . . . . . . . . . . . . V1-T1-19 Type CHQSA Surge Protection Surge Protection Devices and Lightning Arresters . . . . V1-T2-3 Type CHSA Surge Protection Surge Protection Devices and Lightning Arresters . . . . V1-T2-3 V1-A3-10 V1-T4-19 V1-T4-19 V1-T4-18 V1-T4-18 Volume 1—Residential and Light Commercial CA08100002E—April 2014 www.eaton.com
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : Eaton Corporation Create Date : 2011:07:24 09:29:06-04:00 Modify Date : 2014:06:25 07:41:21-04:00 Subject : CA08100002E Has XFA : No XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Metadata Date : 2014:06:25 07:41:21-04:00 Creator Tool : Adobe InDesign CS4 (6.0) Format : application/pdf Title : Volume 01—Residential and Light Commercial Creator : Eaton Corporation Description : CA08100002E Document ID : uuid:d5c50c0d-4aa2-4977-b12a-f8e4e521b5cd Instance ID : uuid:b2a543a4-d0f6-43c8-9e0e-073a03cbf330 Producer : Adobe PDF Library 9.0 Page Layout : SinglePage Page Count : 419EXIF Metadata provided by EXIF.tools