Resi 2004

136942-Catalog 136942-Catalog 136942-Catalog 785901 Batch4 unilog cesco-content

2014-06-03

: Pdf 102143-Attachment 102143-Attachment 785901 Batch4 unilog

Open the PDF directly: View PDF PDF.
Page Count: 72

Residential
Products Catalog
The SQUARE D Multi-Link System is a comprehensive home network
solution that allows you to maximize the use of your home technology today
and ensure that your home has the infrastructure required to support
tomorrow’s advances. Whether you need greater functionality for your home
office, a local area network, high-speed internet access, or more convenience
in accessing your home entertainment equipment, the SQUARE D Multi-Link
System offers a reliable, easy-to-use, and affordable solution.
With the SQUARE D Multi-Link System, you will be able to:
Control video equipment from any room via the unique infrared remote
control technology
Add system functionality at any time - The SQUARE D Multi-Link System
features the industry’s most open design, allowing you to create your own
custom system, whether using Square D option upgrades or third-party
add-ons. Even with today’s technological advances, you will never have to
worry about your Multi-Link System becoming out dated.
Know you are protected by the leader in electrical protection - Today’s
homeowner has more costly electronic equipment than ever before.
Protect that equipment with our SURGEBREAKER PLUS Multi-Path
Surge Protector. A perfect complement to your SQUARE D Multi-Link
System, the SURGEBREAKER PLUS provides surge protection up to
20,000 volts for your telephone, video and electrical lines - all backed by
a 5-year $50,000 warranty.
Headquartered in Palatine, Ill., the
North American Operating Division of
Schneider Electric had sales of $2.7
billion in 2002. The North American
Operating Division is one of three geo-
graphic divisions of Schneider Electric,
headquartered in Paris, France, and
markets the Merlin Gerin, Square D and
Telemecanique brand products to
customers in the United States, Canada
and Mexico. In the United States,
Schneider Electric is best known by its
flagship Square D brand, with
Telemecanique becoming increasingly
known in the industrial control and
automation markets and supported by
many Square D distributors. For 100
years, Square D has been a market-
leading brand of electrical distribution
and industrial control products, systems
and services. Schneider Electric is a
global electrical industry leader with
2003 sales of approximately $9.9 billion.
It is the world’s leading manufacturer
of electrical distribution, industrial
control and automation products and
systems, and the only electrical
manufacturer dedicated solely to the
distribution and control of electricity.
RESIDENTIAL CONSTRUCTION
Scheider Electric is the leading supplier of electrical
equipment for residential construction in the United
States, Canada and Mexico. Focused residential sales
and marketing teams concentrate on serving residential
contractors, single and multi-family home builders,
manufactured housing companies, electrical wholesale
distributors and home improvement retailers.
RESIDENTIAL
PRODUCTS
Table of
CONTENTS
Load Centers and Circuit Breakers
Load Centers and Circuit Breakers Product Information . . . . . . . . . . . . . . 2
QO®Circuit Breakers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Plug-On Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
QO Circuit Breaker Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
QO Load Centers
Series Rating Class 1100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Indoor - Main Lug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Indoor - Main Breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Rainproof - Main Lug, Main Breaker. . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Three Phase - Main Lug, Main Breaker . . . . . . . . . . . . . . . . . . . . . . . 10
Special Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-12
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Voltage Testers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Homeline®Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Homeline Load Centers
Series Rating Class 1170. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Indoor - Main Lug, Main Breaker . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Rainproof - Main Lug, Main Breaker. . . . . . . . . . . . . . . . . . . . . . . . . . 18
QO and Homeline Load Centers
Indoor - Dimensions, Knockouts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Rainproof - Dimensions, Knockouts, Bolt-On Hubs . . . . . . . . . . . . . . . 20
QO Load Centers Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Three Phase Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Homeline Load Centers Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . 23
Combination Service Entrance Devices
CSED Product Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Rainproof - Meter-Mains . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Rainproof - All-In-Ones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Circuit Breakers, Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Enclosed Molded Case Switches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Circuit Breaker Enclosures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Surge Protection
Surge Protection Product Information . . . . . . . . . . . . . . . . . . . . . . . . . . 30
TVSS and Surge Arresters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Air Conditioning Disconnects
Air Conditioning Disconnects Product Information . . . . . . . . . . . . . . . . . 32
Air Conditioning Disconnects . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Voltage Tester . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33
Servicepak Power Outlet Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Structured Wiring
Square D Structured Wiring Product Information . . . . . . . . . . . . . . . . . . 35
Square D Multi-Link Structured Wiring System . . . . . . . . . . . . . . . . . 36-37
Metering
Metering Product Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Individual Meter Sockets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Ganged and Test Block Sockets and Accessories . . . . . . . . . . . . . . . . . 40
Individual Ganged and Test Block Sockets Dimensions . . . . . . . . . . . . . 41
MP Meter-Pak Meter Centers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42-43
MP Meter-Pak Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
EZ Meter-Pak®Meter Centers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45-50
EZ Meter-Pak Meter Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
EZ Meter-Pak SCCR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52-53
Switches
Safety Switches and Disconnects Product Information . . . . . . . . . . . . . . 54
General Duty Safety Switches
Light Duty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Accessories, Lug Data and Dimensions . . . . . . . . . . . . . . . . . . . . . . . 56
Double Throw Safety Switches
Fusible and Not Fusible . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
240 Volt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Application Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60-61
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62
Square D Warranties . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63-64
Square D Conditions of Sale . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65-68
1
Load Centers &
CIRCUIT BREAKERS
2
QO®Load Centers and Circuit Breakers
Square D load centers are the leading choice of electrical contractors
and electricians. Every feature of the QO Load Center was designed to
provide clear advantages. QO Circuit Breakers also have features no other
manufacturer can offer. These quality, industry exclusive products keep
Square D ahead of the competition and are builders’ and electrical
contractors’ first choice in electrical protection.
Load Center Features:
Shielded Copper Bus Bar.
Available in single and three phase.
Ground Bar is included with all main lugs load centers with three
mounting locations.
Convertible Mains let you meet changing job-site requirements.
22,000/10,000 AIR standard series connected rating.
Tangential main service knockouts.
Enclosure rotates for top or bottom feed to reduce service cable waste.
QO Circuit Breaker Features:
Qwik-Open®circuit breaker protection.
Exclusive Visi-Trip®red indicator.
Quick make - quick break mechanism.
Plug-on design, easy to install.
Homeline®Load Centers and Circuit Breakers
Homeline Load Centers and Circuit Breakers are built with the same
Square D quality you have come to expect at a price that makes them
the best value in their class. Feature for feature, Homeline products
outclass the competition.
Features include:
Straight-In Mains.
Convertible Mains let you meet changing job-site requirements.
Split-branch neutral with up to 50% more terminations than required.
Bus and interior assembly is among the most rugged in the industry.
Three ground bar mounting locations.
22,000/10,000 AIR standard series connected rating.
Tangential main service knockouts.
Enclosure rotates for top or bottom feed to reduce service cable waste.
LOAD CENTERS
3
QO® Circuit Breakers
with VISI-TRIP® Indicator
Class 730, 731, 733
© 2004 Schneider Electric
All Rights Reserved
6/7/04
www.SquareD.com
For the most up-to-date information
DE2A Discount
Schedule
Circuit Limiting QOT Tandem Breakers
QOT tandem breakers have a mounting cam as
shown. Installation into a QO load center can only
be made in those positions having a mounting
pan rail slot. Meets Par. 408.15 of NEC
®
. UL
Listed as Class CTL.
Circuit Breaker Wire Sizes
a
Breaker
Type
Ampere
Rating
Wire Size (AWG)
Al Cu
QO
1-pole
10–30 #14–8 #14–8
10–30 . . . (2) #14–10
35–70 #8–2 #8–2
QO
2-pole
10–30 #14–8 #14–8
10–30 . . . (2) #14–10
35–70 #8–2 #8–2
80–125 #4–2/0 #4–2/0
150–200 #4–
300 kcmil
#4–
300 kcmil
QO
3-pole
10–30 #14–8 #14–8
35–70 #8–2 #8–2
80–125 #4–2/0 #4–2/0
QOB-VH 110–150 #4–
300 kcmil
#4–
300 kcmil
QOT 15–20 #12–8 #14–8
QO-AFI,
QO-GFI &
QO-EPD
15–30 #12–8 #14–8
40, 50, 60 #12–4 #14–6
QO-PL 10–60 #12–2 #14–2
Pan Rail Slot
Rail Bead
Mounting Cam
QO 1-pole
1 Space Required
QO 2-pole
2 Spaces Required
QOT 1-pole
Tandem
1 Space Required
QO Three-pole
3 Spaces Required
4 Spaces Required
QO2200 2-pole
200 A
QO Miniature Circuit Breakers
Square D QO miniature circuit breakers are plug-on products for use in QO load centers.
a
10–30 A circuit breakers are suitable for use with 60°C or 75°C conductors. 35–125 A circuit breakers are suitable for use with 75°C conductors.
b
UL Listed 5000 AIR on corner grounded Delta systems.
c
UL Listed as HACR type for use with air conditioning, heating and refrigeration equipment having motor group combinations and marked for use
with HACR type circuit breakers.
d
UL Listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting loads.
e
Requires four spaces (#1–300 kcmil Al/Cu). Not suitable for use in 3-phase panel. Use only in single phase panel rated 150 A or greater.
f
Order only. Contact your nearest Square D/Schneider Electric sales office.
g
UL Listed for use ahead of QO, QO-GFI, QO-EPD, QOT, and QO-PL 10,000 AIR circuit breakers to permit their application at 22,000 A fault level.
h
100 A maximum branch mounted opposite.
i
Includes two circuit breakers (one QO2030 and one QO3020) and handle tie QOTHT.
Plug-On Circuit Breakers—UL Listed Amperes Interrupting Rating (AIR) In Amperes RMS Symmetrical
Amperes
Rating
a
1-pole—120/240 Vac 2-pole—120/240 Vac
Common Trip
2-pole—240 Vac
b
Common Trip
Three-pole—240 Vac
Common Trip
Catalog Number Price Catalog Number Price Catalog Number Price Catalog Number Price
10,000 AIR
10 QO110
$19.40
QO210
$44.70
. . .
. . .
QO310
$165.00
15 QO115
cd
19.40
QO215
c
44.70
QO215H
$133.00
QO315
c
165.00
20 QO120
cd
19.40
QO220
c
44.70
QO220H
133.00
QO320
c
165.00
25 QO125
c
19.40
QO225
c
44.70
QO225H
133.00
QO325
c
165.00
30 QO130
c
19.40
QO230
c
44.70
QO230H
133.00
QO330
c
165.00
35 QO135
c
19.40
QO235
c
44.70
. . .
. . .
QO335
c
165.00
40 QO140
c
19.40
QO240
c
44.70
QO240H
133.00
QO340
c
165.00
45 QO145
c
19.40
QO245
c
44.70
. . .
. . .
QO345
c
165.00
50 QO150
c
19.40
QO250
c
44.70
QO250H
133.00
QO350
c
165.00
60 QO160
c
19.40
QO260
c
44.70
QO260H
133.00
QO360
c
165.00
70 QO170
c
44.70
QO270
c
89.00
QO270H
149.00
QO370
c
210.00
80 . . .
. . .
QO280
c
126.00
QO280H
210.00
QO380
c
244.00
90 . . .
. . .
QO290
c
126.00
QO290H
210.00
QO390
c
244.00
100 . . .
. . .
QO2100
c
126.00
QO2100H
210.00
QO3100
c
244.00
110 . . .
. . .
QO2110
c
285.00
. . .
. . .
. . .
. . .
125 . . .
. . .
QO2125
c
285.00
. . .
. . .
. . .
. . .
150 . . .
. . .
QO2150
ce
327.00
. . .
. . .
. . .
. . .
175 . . .
. . .
QO2175
ce
327.00
. . .
. . .
. . .
. . .
200 . . .
. . .
QO2200
ce
327.00
. . .
. . .
. . .
. . .
Molded Case Switch 60 A max.–240 Vac . . .
. . .
QO200
46.90
QO300
165.00
Molded Case Switch 100 A max.–240 Vac . . .
. . .
QO2000
f
133.00
QO3000
f
244.00
22,000 AIR
15 QO115VH
cd
$42.30
QO215VH
gc
$97.00
. . .
. . .
QO315VH
gc
$247.00
20 QO120VH
cd
42.30
QO220VH
gc
97.00
. . .
. . .
QO320VH
gc
247.00
25 QO125VH
c
48.50
QO225VH
gc
97.00
. . .
. . . QO325VH gc 247.00
30 QO130VHc48.50 QO230VH gc 97.00 . . . . . . QO330VH gc 247.00
40 . . . . . . QO240VH gc 97.00 . . . . . . QO340VH gc 247.00
50 . . . . . . QO250VH gc 97.00 . . . . . . QO350VH gc 247.00
60 . . . . . . QO260VH gc 97.00 . . . . . . QO360VH gc 247.00
70 . . . . . . QO270VH gc 149.00 . . . . . . QO370VH gc 318.00
80 . . . . . . QO280VH gc 210.00 . . . . . . QO380VH gc 353.00
90 . . . . . . QO290VH gc 210.00 . . . . . . QO390VH gc 353.00
100 . . . . . . QO2100VH gc 210.00 . . . . . . QO3100VH gc 353.00
110 . . . . . . QO2110VH ghc 689.00 . . . . . . . . . . . .
125 . . . . . . QO2125VH ghc 689.00 . . . . . . . . . . . .
150 . . . . . . QO2150VH gce 707.00 . . . . . . . . . . . .
175 . . . . . . QO2175VH gce 707.00 . . . . . . . . . . . .
200 . . . . . . QO2200VH gce 707.00 . . . . . . . . . . . .
42,000 AIR
40 . . . . . . QOH240cf $211.00 . . . . . . . . . . . .
45 . . . . . . QOH245cf 211.00 . . . . . . . . . . . .
50 . . . . . . QOH250cf 211.00 . . . . . . . . . . . .
60 . . . . . . QOH260cf 211.00 . . . . . . . . . . . .
70 . . . . . . QOH270c352.00 . . . . . . . . . . . .
80 . . . . . . QOH280c434.00 . . . . . . . . . . . .
90 . . . . . . QOH290c434.00 . . . . . . . . . . . .
100 . . . . . . QOH2100c434.00 . . . . . . . . . . . .
110 . . . . . . QOH2110cf 926.00 . . . . . . . . . . . .
125 . . . . . . QOH2125c926.00 . . . . . . . . . . . .
65,000 AIR
15 QH115cd $78.00 QH215c$195.00 . . . . . . QH315c$338.00
20 QH120cd 78.00 QH220c195.00 . . . . . . QH320c338.00
25 QH125cf 78.00 QH225cf 195.00 . . . . . . QH325cf 338.00
30 QH130c78.00 QH230c195.00 . . . . . . QH330c338.00
QOT Tandem Circuit Breakers—10,000 AIR
Ampere
Ratinga
1-pole Tandem
120/240 Vac
2-pole Tandem
120/240 Vac
Catalog No. Price Catalog No. Price
15 & 15
15 & 20
20 & 20
QOT1515c
QOT1520c
QOT2020c
$38.60
38.60
38.60
Order two QOT1515 or QOT2020 circuit breakers and handle tie
Cat. No. QOTHT at $2.50 for common switching of center two poles.
Replacement Tandem Breakers
For Use in Old Style Non-Class CTL QO Load Centers—10,000 AIR
Ampere
Ratinga
1-pole—120/240 Vac Two Single-pole
Individual Trip 120/240 Vac
1 Space Required 2 Spaces Required
Catalog No. Price Catalog No. Price
10 . . . . . . . Order Two QO1515 or
QO2020 circuit breakers
and handle tie Cat. # QOTHT
15 & 15 QO1515 c$48.50
15 & 20 QO1520 c48.50
20 & 20 QO2020 c48.50 . . . . . . .
20 & 30 QO2030 c48.50 QO20303020 i$89.00
30 & 20 QO3020 c48.50 . . . . . . .
30 & 30 QO3030 c48.50 . . . . . . .
Additional Infmation
Accessories . . . . . . . . . . . .page 13
LOAD CENTERS
www.SquareD.com
For the most up-to-date information
4
QO® Circuit Breakers
Class 685, 690, 730, 912, 950
© 2004 Schneider Electric
All Rights Reserved
6/7/04
Plug-On Circuit Breakers—UL Listed Amperes Interrupting Rating (AIR) In Amperes RMS Symmetrical
1-pole
QO-AFI 1-pole
QO-GFI
2-pole
QO-GFI
Two-wire
QO-SWN
Three-wire
QO-SWN
QO
1-pole
With Shunt Trip
QO-K Key
Operated
QO-HM High magnetic trip circuit breakers are recommended for applications where high
initial inrush may occur and for individual dimmer applications.
Ampere
Rating
a
1-pole
Catalog No Price
120 Vac—10,000 AIR
15 QO115HMcd $20.40
20 QO120HMcd 20.40
QO-AFI QO Circuit Breakers with arc fault protection in accordance with UL1699.
Ampere
Rating
a
1-pole 120 Vac 1-pole 120 Vac
10,000 AIR 22,000 AIR
1 Space Required 1 Space Required
Catalog No. Price Catalog No. Price
15 QO115AFId$160. QO115VHAFId$331.
20 QO120AFId160. QO120VHAFId331.
QO-GFI QWIK-GARD® circuit breakers provide overload and short circuit protection,
combined with Class A ground fault protection. Class A denotes a ground fault
circuit interrupter that will trip when a fault current to ground is 6 milliamperes or
more, for people protection. Do not connect to more than 250 feet of load conductor
for the total one-way run to prevent nuisance tripping.
Ampere
Rating
a
QWIK-GARD Circuit Breakers
With Ground Fault Circuit Interrupter
1-pole
120 Vac
2-pole Common Trip
120/240 Vac
10,000 AIR 22,000 AIR 10,000 AIR
1 Space Required 1 Space Required 2 Spaces Required
Catalog No. Price Catalog No. Price Catalog No. Price
15 QO115GFI $155. QO115VHGFI $321. QO215GFI $275.
20 QO120GFI 155. QO120VHGFI 321. QO220GFI 275.
25 QO125GFI 155. QO125VHGFI 321. QO225GFI 275.
30 QO130GFI 155. QO130VHGFI 321. QO230GFI 275.
40 . . . . . . . . . . . . . . QO240GFI 275.
50 . . . . . . . . . . . . . . QO250GFI 275.
60 . . . . . . . . . . . . . . QO260GFIb275.
QO-EPD QO-EPD circuit breakers provide overload and short circuit protection combined
with Class B ground fault protection. They are designed to provide ground fault
protection of equipment at a 30 milliampere level. They are not designed to protect
people from electrical shock.
Ampere
Rating
a
1-pole
120 Vac
2-pole Common Trip
120/240 Vac
10,000 AIR 10,000 AIR
1 Space Required 2 Spaces Required
Catalog No. Price Catalog No. Price
15 QO115EPD $273. QO215EPD $440.
20 QO120EPD 273. QO220EPD 440.
25 QO125EPD 273. QO225EPD 440.
30 QO130EPD 273. QO230EPD 440.
40 . . . . . . . QO240EPD 440.
50 . . . . . . . QO250EPD 440.
60 . . . . . . . QO260EPDb440.
QO-SWN Switch Neutral Common Trip 2002 NEC® 514.11
Ampere
Rating
a
2 Wire 120 Vac 3 Wire 120/240 Vac
10,000 AIR 10,000 AIR
2 Spaces Required 3 Spaces Required
Catalog No. Price Catalog No. Price
10 QO210SWN $63. QO310SWN $95.
15 QO215SWN 63. QO315SWN 95.
20 QO220SWN 63. QO320SWN 95.
25 QO225SWN 63. QO325SWN 95.
30 QO230SWN 63. QO330SWN 95.
40 QO240SWN 63. QO340SWN 95.
50 QO250SWN 63. QO350SWN 95.
a10–30 ampere breakers are suitable for use with 60°C or 75°C conductors. 35–60 ampere
circuit breakers are suitable for use with 75°C conductors.
bSuitable only for feeding 240 Vac and 208 Vac 2 wire loads. Does not contain load neutral
connection.
cUL Listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting
loads.
dUL Listed as HACR type for use with air conditioning, heating and refrigeration equipment
having motor group combinations and marked for use with HACR type circuit breakers.
Non-automatic (Standard) Miniature Switches
Miniature non-automatic switches have the same physical packaging as
miniature circuit breakers, but open only when the handle is switched to
the OFF position.
Non-automatic switches provide no overcurrent protection or short
circuit protection. They must not be used on systems that have an
available fault current greater than the values listed in the table.
Non-automatic switches are UL Listed per UL 1087 and are CSA
certified.
QO-HID QO-HID Circuit Breakers
HID circuit breakers are for use on circuits feeding fluorescent and high intensity
discharge (HID) lighting systems such as mercury vapor, metal halide, or high
pressure sodium. These circuit breakers are physically interchangeable with QO
circuit breakers.
Ampere
Rating
a
1-pole
120/240 Vac
2-pole Common Trip
120/240 Vac
3-pole Common Trip
240 Vac
10,000 AIR 10,000 AIR 10,000 AIR
1 Space Required 2 Spaces Required 3 Spaces Required
Catalog No. Price Catalog No. Price Catalog No. Price
15 QO115HIDc$25.40 QO215HID $58.00 QO315HID $200.00
20 QO120HIDc25.40 QO220HID 58.00 QO320HID 200.00
25 QO125HID 25.40 QO225HID 58.00 QO325HID 200.00
30 QO130HID 25.40 QO230HID 58.00 QO330HID 200.00
40 QO140HID 25.40 QO240HID 58.00 . . . . . . .
50 QO150HID 25.40 QO250HID 58.00 . . . . . . .
QO-K Key operated QO circuit breakers are available in single-pole construction and can be
mounted in any single-pole space which will accept a standard QO. These circuit
breakers can be turned ON or OFF or to RESET with a special key (Catalog No.
QOK10) included with the circuit breaker. These circuit breakers are UL Listed and
available as shown in the table.
120 Vac—10,000 AIR (1 Space Required)
Ampere
Rating
a
Catalog No. Price
10 QO110K $109.
15 QO115K 109.
20 QO120K 109.
25 QO125K 109.
30 QO130K 109.
Non-automatic Miniature Switches, 240 Vac 10 kA
Ampere
Rating
2-pole 3-pole
Catalog No. Price Catalog No. Price
60 QO200 $46.90 QO300 $165.00
100 QO2000 133.00 QO3000 244.00
60 QOU200 58.00 QOU300 190.00
100 QOU2000 164.00 QOU3000 277.00
125 QOU20001 302.00 QOU30001 477.00
DE2A Discount
Schedule
LOAD CENTERS
5
QO® Circuit Breaker Accessories
Class 1130
© 2004 Schneider Electric
All Rights Reserved
6/7/04
www.SquareD.com
For the most up-to-date information
Factory-installed Accessories for Use with QO Miniature Circuit Breakers
Factory-installed electrical accessories take up an additional pole space on QO®, QO-GFI, QO-EPD and QO-SWN circuit breakers. All AC electrical
accessories shown below are rated for 50/60 Hz. Accessories are not available for QOB-VH (2-pole 150 A and 3-pole 110–150 A) circuit breakers or
QO molded case switches and the 125, 150 or 200 A QO circuit breakers. QO circuit breakers will accept only one accessory per circuit breaker.
Undervoltage trip is not available on miniature circuit breakers.
aNot suitable for use in 3-phase panels. Use only in single phase panel rated 150 A or greater.
Accessories for Use with QO Miniature Circuit Breakers
Description Catalog Number Price Schedule
HANDLE ATTACHMENTS
Handle Tie: Converts any two adjacent 120/240 Vac single-pole QO breakers to independent trip 2-pole . . . . . . . . . . . . . . . . . . . . . . QO1HT $2.50 DE2E
Converts any two adjacent 120/240 Vac single-pole side-by-side QOT breakers to independent trip 2-pole . . . . . . . . . . QOTHT 2.50 DE2E
Handle Clamp: Clamp for holding QO single-pole handle in “ON’’ or “OFF’ position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QO1LO 2.50 DE2E
Clamp for holding QO or Q1 either 1, 2 or 3-pole breaker handles in “ON’ or “OFF’ position . . . . . . . . . . . . . . . . . . . . . . HLO1 6.60 DE2E
Handle Padlock Attachment: For padlocking single-pole QO breaker in “ON’ or “OFF’’ position
Loose attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QOHPL 6.30 DE2E
Fixed attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QO1PA 7.10 DE2E
For padlocking single-pole QO circuit breaker in “OFF’’ position only, fixed attachment. . . . . . . . . . . . . . . . . . . . . . . . . . . QO1PAF 29.00 DE2E
For padlocking single-pole side-by-side QOT breaker in “ON’’ or “OFF’ position . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QOTHPA 7.40 DE2E
For 2 and 3-pole QO and Q1 breakers which require padlocking in either “ON’’ or “OFF’ position. (Not GFI)
Loose attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QO1HPL 7.10 DE2E
Fixed attachment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QO1PL 7.10 DE2E
For padlocking 2 and 3-pole QO circuit breakers in “OFF’’ position only, fixed attachment. . . . . . . . . . . . . . . . . . . . . . . . QO2PAF 17.20 DE2E
For padlocking single-pole QO-GFI, QO-AFI and QO-EPD circuit breakers in “OFF’’ position only, fixed attachment. . QOGFI1PAF 34.00 DE2E
For padlocking 2-pole QO-GFI in either “ON’’ or “OFF’ position, fixed attachment. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . GFI2PA 6.10 DE2A
For padlocking 2-pole QO-GFI and QO-EPD circuit breakers in “OFF’’ position only, fixed attachment. . . . . . . . . . . . . . QOGFI2PAF 25.60 DE2E
SUB-FEED LUGS 60 ampere 2-pole plug-on – 2 spaces required (#6–2 Al/Cu) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QO60SL 31.40 DE2A
125 ampere 2-pole plug-on – 2 spaces required (#12–2/0 Al/Cu) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QO2125SL 91.00 DE2A
225 ampere 2-pole plug-on – 4 spaces required (#4–300 Al/Cu) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QO2225SLa205.00 DE2A
125 ampere 3-pole plug-on – 3 spaces required (#12–2/0 Al/Cu) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QO3125SL 91.00 DE3
MECHANICAL INTERLOCK
ATTACHMENT:
For interlocking the handles of two 2-pole or one 2-pole and one 1-pole QO and Q1 breakers mounted
side-by-side so that only one circuit breaker can be “ON’ at a time (Not QOU) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
QO2DTI
16.60
DE2E
With Retaining Kit: QO2DTI mechanical interlock attachment with retaining kits for securing two adjacent back-fed circuit
breakers in dual power supply applications. Can be used with (2) 2-poles or (1) 2-pole and (1) 1-pole QO
circuit breakers in QO816L100 load centers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
QO2DTIM
42.00
DE2E
Accessory Description Rated
Voltage
Coil
Burden Suffix List Price
Adder Accessory Description Contact
Comb.
Max.
Voltage
Max.
Load Suffix List Price
Adder
SHUNT
TRIP
Tr ips the circuit breaker from a
remote location by means of a trip
coil energized from a separate
circuit. A 120 Vac shunt trip will
operate at 55% or more of rated
voltage. All other shunt trips will
operate at 75% or more of rated
voltage.
Application
•For use with momentary or
maintained push button.
Not available on QO-GFI,
QO-EPD.
Shunt trip terminals accept (2)
#14–#12 AWG Cu.
AC/DC
12
24
AC 120
208
60 VA
168 VA
72 VA
-1042
-1042
$126.
AUXILIARY
SWITCHES
Monitors circuit breaker contact status
and provides a remote signal indicating
the circuit breaker contacts are OPEN
or CLOSED.
Application
•Auxiliary switch terminals accept
(2) #14–#12 AWG Cu leads.
Leads (EH): Yellow for “A’’, Blue for
“B’’, Striped common #18 AWG Cu.
1A
1B
AC 120
AC 120
5 A
5 A
-1200
-1201
$88.
88.
-1021 126.
228 VA -1021
240 288 VA -1021
ALARM
SWITCHES
Used with control circuits and is
actuated only when the circuit breaker
has tripped. Standard construction
includes a normally-open contact.
Application
Leads: Alarm switch terminals accept
(2) #14–#12 AWG Cu leads.
1A AC 120 5 A -2100 88.
HLO1
QO1HPL
QO1LO
QO1PA
QOTHPA
QO1HT
QO1PL
QO2DTI
DE2 Discount
Schedule
LOAD CENTERS
www.SquareD.com
For the most up-to-date information
6
QO® Load Centers
Series Rating
Class 1100
© 2004 Schneider Electric
All Rights Reserved
6/7/04
The rating of the load center is equal to the lowest interrupting rating of any circuit breaker installed or combination series connected circuit breaker.
Additional or replacement circuit breakers MUST have an interrupting and voltage rating equal to or greater than that of the circuit breaker with the lowest
interrupting and voltage rating presently installed. See load center interior for circuit breaker types.
a240 Vac 3 Phase 4 Wire Delta: When wired for Delta system, phase "B" must be 208 V to neutral. Two-pole circuit breakers connected to phase "B" must be rated 240 V (QO-H). Single-pole circuit
breakers must not be connected to phase "B".
b240 Vac 3 Phase 4 Wire Delta: When wired for Delta system, phase "B" must be 208 V to neutral. For this Short Circuit Current Rating, single-pole and two-pole circuit breakers must not be connected
to phase "B".
c100 amperes maximum branch circuit breaker in load centers with 125 A maximum mains rating.
dSee circuit breaker for voltage and interrupting rating.
eQO includes suffixes: GFI, EPD, PL, AS and AFI. QO-VH includes suffixes GFI and AFI
Short Circuit Current Rating
Maximum Short Circuit
Current Rating
(RMS Symmetrical)
Load Center Voltage Rating
240 Vac Max.
Integral or Remote
Square D Circuit Breaker or Remote Fuses Square D Branch Circuit Breaker
Fuse Class
Catalog
Designation
d
Current
Rating
Amperes
Max.
Catalog
Designation
de
Current Rating Amperes
Systems Voltage 1-pole 2-pole 3-pole
5,000 240 Vac, 3 Phase 3 Wire Grounded "B" phase. QO-H 15–100
10,000
120/240 Vac, 1 Phase 3 Wire QO 10–70 10–200c
QOT 15–30 …
208Y/120 Vac, 3 Phase 4 Wire QO 10–70 10–125c10–100
240/120 Vac, 3 Phase 4 Wire Delta a………
QO-H 15–100 …
QO 10–70 10–125c10–100
240 Vac, 3 Phase 3 wire Delta QO-H 15–100 …
QO … 10–100
22,000
120/240 Vac, 1 Phase 3 Wire QO-VH 15–30 15–200c
208Y/120 Vac, 3 Phase 4 Wire QO-VH 15–30 15–125c15–100
240/120 Vac, 3 Phase 4 Wire Delta b………QO-VH 15–30 15–125c15–100
240 Vac, 3 Phase 3 wire Delta QO-VH 10–100
42,000 120/240 Vac, 1 Phase 3 Wire QOH 40–125c
208Y/120 Vac, 3 Phase 4 Wire QOH 40–125c
65,000
120/240 V ac, 1 Phase 3 Wire QH 15–30 15–30
208Y/120 Vac, 3 Phase 4 Wire QH 15–30 15–30 15–30
240/120 Vac, 3 Phase 4 Wire Delta b………QH 15–30 15–30 15–30
240 Vac, 3 Phase 3 wire Delta QH 15–30
Series Combination Short Circuit Current Rating
22,000
120/240 Vac, 1 Phase 3 Wire QOM-VH 225 QO 15–70 15–200c
QOT 15–30 …
120/240 Vac, 1 Phase 3 Wire QO-VH 200 QO 15–70 15–200c
QOT 15–30 …
208Y/120 Vac, 3 Phase 4 Wire QO-VH 100 QO 15–70 15–100 15–100
240/120 Vac, 3 Phase 4 Wire Delta bQO-VH 100 QO 15–70 15–100 15–100
240 Vac, 3 Phase 3 wire Delta QO-VH 100 QO 15–100
25,000
120/240 Vac, 1 Phase 3 Wire QD 225 QO 15–70 15–200c
QOT 15–30 …
208Y/120 Vac, 3 Phase 4 Wire QD 225 QO 15–70 15–125c15–30
QO-VH 15–30 15–125c15–100
240/120 Vac, 3 Phase 4 Wire Delta a…QD225
QO-H 15–100 …
QO 15–70 15–125c15–30
QO-VH 15–30 15–125c15–100
240 Vac, 3 Phase 3 wire Delta QD 225
QO-H 15–100 …
QO … 15–30
QO-VH … 15–100
42,000 120/240 Vac, 1 Phase 3 Wire QOH 125 QO 15–70 15–100
QOT 15–30 …
65,000
120/240 Vac, 1 Phase 3 Wire QG 225 QO 15–70 15–200c
QOT 15–30 …
208Y/120 Vac, 3 Phase 4 Wire QG 225 QO 15–70 15–125c15–30
QO-VH 15–30 15–125c15–100
240/120 Vac, 3 Phase 4 Wire Delta a…QG225
QO-H 15–100 …
QO 15–70 15–125c15–30
QO-VH 15–30 15–125c15–100
240 Vac, 3 Phase 3 wire Delta QG 225
QO-H 15–100 …
QO … 15–30
QO-VH … 15–100
100,000
120/240 Vac, 1 Phase 3 Wire
QJ 225 QO 15–70 15–200c
QOT 15–30
208Y/120 Vac, 3 Phase 4 Wire
QJ 225 QO 15–70 15–125c15–30
QO-VH 15–30 15–125c15–100
120/240 Vac, 1 Phase 3 Wire T3 200 QO 15–70 15–200c
QOT 15–30 …
208Y/120 Vac, 3 Phase 4 Wire T3 200 QO 15–70 15–125c15–100
240/120 Vac, 3 Phase 4 Wire Delta bT3 200 QO 15–70 15–125c15–100
240 Vac, 3 Phase 3 wire Delta T3 200 QO 15–100
LOAD CENTERS
7
QO® Load Centers
Indoor—Single Phase, Main Lug
Class 736, 1130
© 2004 Schneider Electric
All Rights Reserved
6/7/04
www.SquareD.com
For the most up-to-date information
DE3A vPE1A Discount
Schedule
Above listings thru 200 A mains rating meet Federal Specification W-P-115c as
Type 1, Class 2.
aMaximum number of single pole branch circuits utilizing QO and/or QOT circuit breakers.
bUL short circuit current rating depends on lowest interrupting rating of circuit breaker
installed.
cWill not accept QO-EPD or QWIK-GARD® QO-GFI circuit breakers.
dMains rated 25 A when Al wire is used.
eOrder F for flush device or S for surface device.
fUse #10 maximum size wire for GFI circuit breaker.
g70 A Max. branch circuit breaker and 70 A max. back fed main circuit breaker.
hNo provisions for lock kits.
iCU indicates copper bus.
jCopper bus.
kUL Listed 5000 A short circuit current rating for corner grounded Delta systems.
Use QO-H circuit breakers only.
lSupplied with feed-thru lugs.
mFactory-included.
nInterior only, order box separately.
oPK27GTA includes a #6–2/0 Al/Cu lug.
Single Phase Three Wire—120/240 Vac—UL Listed
Main Lugs (Order QO, QOT, QO-EPD, QO-GFI and QO-PL branch circuit breakers from pages 3 and 4)
Mains
Rating
(A)
Spaces
Max.
Number
Single
Pole
Circuitsa
Max.
Number
of Tandem
Circuit
Breakers
Total
Price
(Interior,
Box &
Cover)
Load Center
Box and Interior
Indoor Cover with Door
(Order Separately)
Main
Wire Size
AWG/kcmil
Equipment
Ground Bar Kit
(Order Separately)
Box No.
See
Page
19
Flush
Catalog No.
Surface
Catalog No. Price
Catalog Number Price Al Cu Catalog No. Price
I
N
D
O
O
R
Fixed Mains—Factory-installed Main Lugs—10,000 RMS Sym. Amperes Short Circuit Current Ratingb
30 2 2 0 $27.80 QO2L30Scd $27.80
Cover Included—Without Door
#12–10 #14–10 PK3GTA-1 $7.60 1
70 2 4 2 45.70 QO24L70F/Sef 45.70 #12–3 #14–4 PK4GTA 7.20 2
100
612 6 58.00 QO612L100F/Seg 58.00 #8–1 PK7GTA 7.80 4
60.00 QO612L100DF/Segh 60.00 Cover Included—With Door #8–1 PK7GTA 7.80 4
816 8 87.00 QO816L100F/Seg 87.00 Cover Included—Without Door #8–1 PK7GTA 7.80 4
95.00 QO816L100DF/Segh 95.00 Cover Included—With Door
100 612 6 74.00 QO612L100DFCU/SCUeghi 74.00 Cover Included—With Door #8–1 PK7GTA 7.80 4
816 8116.00 QO816L100DFCU/SCUeghi 116.00 Cover Included—With Door #8–1 PK7GTA 7.80 4
125 4 8 4 62.00 QO148L125GF/Sej 62.00 Cover Included—Without Door #12–2/0 #14–2/0 PK7GTAm21
Convertible Mains—Factory-installed Main Lugs—65,000 RMS Sym. Amperes Short Circuit Current Ratingbk
QOM1 Main Frame Size—Convertible to Main Circuit Breaker—Copper Bus
125
12 12 0 $131.10 QO112L125G $106.00 QOC16UF QOC16US $25.10
#6–2/0
PK9GTAm6
12 24 12 157.10 QO11224L125G 132.00 QOC16UF QOC16US 25.10 PK15GTAm6
16 16 0 170.10 QO116L125G 145.00 QOC24UF QOC24US 25.10 PK12GTAm7
16 24 8 200.10 QO11624L125G 175.00 QOC24UF QOC24US 25.10 PK15GTAm7
20 20 0 181.10 QO120L125G 156.00 QOC24UF QOC24US 25.10 PK15GTAm7
20 24 4 247.10 QO12024L125G 222.00 QOC24UF QOC24US 25.10 PK15GTAm7
24 24 0 254.10 QO124L125G 229.00 QOC24UF QOC24US 25.10 PK15GTAm7
32 32 0 289.40 QO132L125G 263.00 QOC32UF Use Flush 26.40 PK23GTA & LK100ANm8
Convertible Mains—Factory-installed Main Lugs—65,000 RMS Sym. Amperes Short Circuit Current Ratingbk
QOM2 Main Frame Size—Convertible To Main Circuit Breaker—Copper Bus
150
20 30 10 $279.00 QO12030L150G $221.00 QOC30UF QOC30US $58.00
#6–250
PK23GTA & LK100ANm9
24 24 0 287.00 QO124L150G 229.00 QOC30UF QOC30US 58.00 PK15GTAm9
30 30 0 291.00 QO130L150G 233.00 QOC30UF QOC30US 58.00 PK23GTA & LK100ANm9
200
12 12 0 235.00 QO112L200G 177.00 QOC30UF QOC30US 58.00
#6–250
PK15GTAm9
24 36 12 546.00 QO12436L200TFTl488.00 QOC40UF QOC40US 58.00 PK23GTA & LK100ANm10
30 30 0 316.00 QO130L200G 271.00 QOC30UF QOC30US 58.00 PK23GTA & LK100ANm9
30 40 10 369.00 QO13040L200G 311.00 QOC30UF QOC30US 58.00 PK23GTA & LK100ANm9
40 40 0 497.00 QO140L200G 439.00 QOC40UF QOC40US 58.00 PK23GTA & LK100ANm10
225 42 42 0 552.00 QO142L225G 478.00 QOC42UF QOC42US 74.00 #6–300 PK23GTA & LK100ANm11
Fixed Mains—Factory-installed Main Lugs—65,000 RMS Sym. Amperes Short Circuit Current Ratingbk
400 12 12 0 $1468.00 QON12LS400(Int)n$971.00 MHC50QVF MHC50QVS $422.v(1) #1/0–750 PK27GTAo$22.50 15
MH50 (Box) 75.vor (2) #1/0–300
400 30 30 0 1547.00 QON30LS400(Int) n1050.00 MHC50QVF MHC50QVS 422.v(1) #1/0–750 or 15
MH50 (Box) 75.vor (2) #1/0–300
400 42 42 0 1641.00 QON42LS400(Int) n1125.00 MHC53QVF MHC53QVS 441.v(1) #1/0–750 PK15GTA-6 35.50 17
MH53 (Box) 75.vor (2) #1/0–300
QO816L100F or S
without cover QO120L125G pDo not exceed the load center mains rating.
q22,000 AIR main circuit breaker UL Listed for use ahead of QO, QOT and QO-PL 10,000 AIR
branch circuit breakers to permit their application on systems with up to 22,000 amperes
available fault current.
rWire range listed for QOM circuit breaker kits is the wire range of that circuit breaker. To find
out maximum wire size permitted in a particular load center per UL, see pages 7 thru 12 under
Main Wire Size.
sAdd suffix 1021 for 120, 208 or 240 Vac shunt trip. Add $126.00.
Main Circuit Breaker Kits
Field-installable Main Circuit Breaker (Convertible Load Centers Only)
p
Main Circuit
Breaker
Rating (A)
Use With
Convertible
Load Center
Mains Rating
22,000 AIR qLug Wire Sizer
AWG/kcmil
Al or Cu
Main Circuit
Breaker Price
QOM1 Frame Size
50 100–125 QOM50VH $93.00
#12–2/0
60 100–125 QOM60VH 93.00
70 100–125 QOM70VH 93.00
80 100–125 QOM80VH 134.00
90 100–125 QOM90VH 134.00
100 100–125 QOM100VH 134.00
110 125 QOM110VH 312.00
125 125 QOM125VH 312.00
QOM2 Frame Sizes
100 150–225 QOM2100VH 312.00
#4–300
125 150–225 QOM2125VH 312.00
150 150–225 QOM2150VH 312.00
175 200–225 QOM2175VH 312.00
200 200–225 QOM2200VH 312.00
225 225 QOM2225VH 312.00
QOM2 Frame Size
100–225 Amperes
QOM1 Frame Size
50–125 Amperes
For additional information, reference Catalog #1100CT9901.
LOAD CENTERS
www.SquareD.com
For the most up-to-date information
8
QO® Load Centers
Indoor—Single Phase, Main Circuit Breaker
Class 1130
© 2004 Schneider Electric
All Rights Reserved
6/7/04
Above listings thru 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
aMaximum number of single pole branch circuits utilizing QO and/or QOT circuit breakers.
b22,000 AIR main circuit breaker UL Listed for use ahead of QO, QOT and QO-PL 10,000 AIR
branch circuit breakers to permit their application on systems with up to 22,000 amperes available
fault current.
cUL short circuit current rating depends on lowest interrupting rating of circuit breakers
installed. Also, UL Listed 5000 A short circuit current for corner grounded Delta systems.
Use QO-H circuit breakers only.
dInterior only, order box separately.
e PK27GTA includes a #6–2/0 Al/Cu lug.
Single Phase Three Wire—120/240 Vac—UL Listed
Main Circuit Breaker (Order QO, QOT, QO-EPD, QO-GFI, QO-AFI and QO-PL branch circuit breakers from pages 3 and 4.)
Mains
Rating
(A)
Spaces
aMax.
Number
Single
Pole
Circuits
Max.
Number
of Tandem
Circuit
Breakers
Total Price
(Interior,
Box &
Cover)
Load Center
Box and Interior
Indoor Cover with Door
(Order Separately) Main
Wire Size
AWG/kcmil
Al or Cu
Equipment
Ground Bar Kit
(Order Separately)
Box No.
See
Page
19
Flush
Catalog No.
Surface
Catalog No. Price
Catalog Number Price Catalog No. Price
I
N
D
O
O
R
Convertible Mains —Factory-installed Main Circuit Breaker—22,000 RMS Sym. Amperes Short Circuit Current Rating
—Convertible to Main Lugs (see below) or Lower Amperage Main Circuit Breaker (See page 7) b
QOM1 Main Circuit Breaker Frame Size—Copper Bus
100
12 12 0 $226.10 QO112M100 $201. QOC12UF QOC12US $25.10
#6–1
PK9GTA $8.90 5
16 16 0 253.10 QO116M100 228. QOC20U100F QOC20U100S 25.10 PK12GTA 10.50 6
20 20 0 289.10 QO120M100 264. QOC20U100F QOC20U100S 25.10 PK15GTA 11.40 6
24 24 0 369.10 QO124M100 344. QOC24UF QOC24US 25.10 #6–2/0 PK15GTA 11.40 7
32 32 0 484.10 QO132M100 459. QOC32UF Use Flush 25.10 PK18GTA 12.50 8
125 24 24 0 546.10 QO124M125 521. QOC24UF QOC24US 25.10 #6–2/0 PK15GTA 11.40 7
32 32 0 694.40 QO132M125 668. QOC32UF Use Flush 26.40 PK18GTA 12.50 8
Convertible Mains —Factory-installed Main Circuit Breaker—22,000 RMS Sym. Amperes Short Circuit Current Rating
—Convertible to Main Lugs (see below) or Lower Amperage Main Circuit Breaker (See page 7)b
QOM2 Main Circuit Breaker Frame Size—Copper Bus
150
20 30 10 $547.00 QO12030M150 $489. QOC30UF QOC30US $58.00
#4–250
PK18GTA $12.50 9
24 24 0 566.00 QO124M150 508. QOC30UF QOC30US 58.00 PK15GTA 11.40 9
30 30 0 569.00 QO130M150 511. QOC30UF QOC30US 58.00 PK18GTA 12.50 9
32 32 0 646.00 QO132M150 588. QOC40UF QOC40US 58.00 PK18GTA 12.50 10
200
20 40 20 547.00 QO12040M200 489. QOC30UF QOC30US 58.00
#4–250
PK23GTA 14.20 9
24 24 0 577.00 QO124M200 519. QOC30UF QOC30US 58.00 PK15GTA 11.40 9
30 30 0 586.00 QO130M200 528. QOC30UF QOC30US 58.00 PK18GTA 12.50 9
30 40 10 638.00 QO13040M200 580. QOC30UF QOC30US 58.00 PK23GTA 14.20 9
40 40 0 747.00 QO140M200 689. QOC40UF QOC40US 58.00 PK23GTA 14.20 10
42 42 0 813.00 QO142M200 739. QOC42UF QOC42US 74.00
#4–300
PK23GTA 14.20 11
225 40 40 0 797.00 QO140M225 723. QOC42UF QOC42US 74.00 PK23GTA 14.20 11
42 42 0 835.00 QO142M225 761. QOC42UF QOC42US 74.00 PK23GTA 14.20 11
Fixed Mains—Factory-installed LAL Main Circuit Breaker—42,000 Fully Rated RMS Sym. Amperes Maximum Short Circuit Current Ratingc
300 42 42 0 $4686.00 QON42MS300(Int)d$4107. MHC68VF MHC68VS $504.r(1) #4–500 PK27GTAe
or
PK15GTA-6
$22.50
35.50
16
MH68 (Box) 75.ror (2) #4–3/0
400 42 42 0 4686.00 QON42MS400(Int)d4107. MHC68VF MHC68VS 504.r(1) #4–600 16
MH68 (Box) 75.ror (2) #4–250
For additional information, reference Catalog #1100CT9901.
fDo not exceed the load center mains rating.
gWire range listed for QOL lug kits is the wire range of that lug. To find out maximum wire size
permitted in a particular load center per UL, see pages 7 thru 12 under main wire size.
hIf main circuit breaker knockout has been removed from the load center’s trim, order
appropriate filler plate from page 14.
Main Lug Kits
Field-installable Main Lugs (Convertible Load Centers Only)
Main Lug f
Ampere Rating
Use On
Convertible
Load Center
With Mains Rating
Catalog
Number Price
Lug Wire Size g
AWG/kcmil
Al or Cu
125 100–125 QOL125h$29.40 #6–2/0
225 150–225 QOL225h69.00 #6–300
QOL225QOL125
QO130M150
DE3A rPE1A Discount
Schedule
LOAD CENTERS
9
QO® Load Centers
Rainproof—Single Phase, Main Lugs, Main Circuit Breaker
Class 1130
© 2004 Schneider Electric
All Rights Reserved
6/7/04
www.SquareD.com
For the most up-to-date information
Above listings thru 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
aMaximum number of single pole branch circuits utilizing QO and/or QOT circuit breakers.
bUse #10 maximum size wire for GFI circuit breaker.
c70 A max. branch circuit breaker and 70 A max. back fed main circuit breaker.
dCopper bus.
eUL short circuit current rating depends on lowest interrupting rating of circuit breakers installed.
fUL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only.
gSide hinge door device; allow 114" on left side for door to open.
h22,000 AIR main circuit breaker UL Listed for use ahead of QO, QOT, QO-GFI, QO-EPD and QOPL 10,000 AIR branch circuit breakers to permit their application on systems up to 22,000 A available
fault current.
Single Phase Three Wire—120/240 Vac—UL Listed
Main Lugs (Order QO, QOT, QO-GFI, QO-EPD, QO-AFI and QO-PL branch circuit breakers from pages 3 and 4.)
Mains
Rating
(A)
Spaces
Max. Number
Single
Pole
Circuitsa
Max.
Number
of Tandem
Circuit
Breakers
Total Price
(Interior,
Box and
Cover)
Load Center
Box and Interior
Main
Wire Size
AWG/kcmil
Equipment
Ground Bar Kit
(Order Separately)
Box No.
See
page 20
Catalog Number Price Al Cu Catalog No. Price
R
A
I
N
P
R
O
O
F
Non-Metallic Enclosure
Fixed Mains—Factory-installed Main Lugs—10,000 RMS Sym. Amperes Short Circuit Current Rating
60 2 4 2 $68.00 QO24L60NRNM $68.00 #14–4 #14–4 Factory-incl. 1NM
Metallic Enclosure
Fixed Mains—Factory-installed Main Lugs—10,000 RMS Sym. Amperes Short Circuit Current Rating
40 2 2 0 $75.00 QO2L40RBb$75.00 #12–6 #14–6 PK3GTA-1 $7.60 1R
70 2 4 2 87.00 QO24L70RBb87.00 #12–3 #14–4 PK4GTA 7.20 1R
100
612 695.00 QO612L100RBc95.00
#8–1
PK7GTA 7.80 2R
612 6105.00 QO612L100TRBc105.00 Factory-installed . . . 2R
816 8154.00 QO816L100RBc154.00 PK7GTA 7.80 2R
100 612 6116.00 QO612L100RBCUcd 116.00 #8–1 PK7GTA 7.80 2R
816 8186.00 QO816L100RBCUcd 186.00 PK7GTA 7.80 2R
125 4 8 4 101.00 QO148L125GRBd101.00 #12–2/0 #14–2/0 PK7GTA Factory-incl. 15R
Convertible Mains—Factory-installed Main Lugs—65,000 RMS Sym. Amperes Maximum Short Circuit Currentefg
QOM1 Main Frame Size—Convertible to Main Circuit Breaker—Copper Bus
125
12 12 0 $190.00 QO112L125GRB $190.00
#6–2/0
PK9GTA Factory-incl.
PK15GTA Factory-incl.
PK15GTA Factory-incl.
PK15GTA Factory-incl.
3R
12 24 12 243.00 QO11224L125GRB 243.00 3R
16 24 8 290.00 QO11624L125GRB 290.00 4R
24 24 0 348.00 QO124L125GRB 348.00 4R
Convertible Mains—Factory-installed Main Lugs—65,000 RMS Sym. Amperes Maximum Short Circuit Current efg
QOM2 Main Frame Size—Convertible to Main Circuit Breaker—Copper Bus
150 30 30 0 $391.00 QO130L150GRB $391.00 #6–250 PK23GTA & LK100AN Factory-incl. 6R
200
12 12 0 320.00 QO112L200GRB 320.00
#6–250
PK9GTA Factory-incl. 5R
30 30 0 444.00 QO130L200GRB 444.00 PK23GTA & LK100AN Factory-incl. 6R
30 40 10 476.00 QO13040L200GRB 476.00 PK23GTA & LK100AN Factory-incl. 6R
40 40 0 647.00 QO140L200GRB 647.00 PK23GTA & LK100AN Factory-incl. 7R
225 42 42 0 873.00 QO142L225GRB 873.00 #6–300 PK23GTA & LK100AN Factory-incl. 8R
Single Phase Three Wire—120/240 Vac—UL Listed
Main Circuit Breaker Order QO, QOT, QO-GFI, QO-EPD and QO-PL branch circuit breakers from pages 3 and 4.
Mains
Rating
(A)
Spaces
aMax.
Number
Single
Pole
Circuits
Max.
Number
of Tandem
Circuit
Breakers
Total Price
(Interior,
Box and
Cover)
Load Center
Box and Interior
Main
Wire Size
AWG/kcmil
Al or Cu
Equipment
Ground Bar Kit
(Order Separately)
Box No.
See
page 20
Catalog Number Price Catalog No. Price
R
A
I
N
P
R
O
O
F
Convertible Mains —Factory-installed Main Circuit Breaker—22,000 RMS Sym. Amperes Short Circuit Current Rating
—Convertible to Main Lugs (see page 8) or Lower Amperage Main Circuit Breaker (see page 7)hg
QOM1 Main Circuit Breaker Frame Size—Copper Bus
100
12 12 0 $307. QO112M100RB $307.
#6–2/0
PK9GTA $8.90 3R
16 16 0 336. QO116M100RB 336. PK12GTA 10.50 4R
20 20 0 368. QO120M100RB 368. PK15GTA 11.40 4R
125 24 24 0 636. QO124M125RB 636. #6–2/0 PK15GTA 11.40 4R
Convertible Mains —Factory-installed Main Circuit Breaker—22,000 RMS Sym. Amperes Short Circuit Current Rating
—Convertible to Main Lugs (see page 8) or Lower Amperage Main Circuit Breaker (see page 7)hg
QOM2 Main Circuit Breaker Frame Size—Copper Bus
150 20 30 10 $635. QO12030M150RB $635. #4–250 PK18GTA $12.50 5R
30 30 0 748. QO130M150RB 748. PK18GTA 12.50 6R
200
20 40 20 636. QO12040M200RB 636.
#4–250
PK23GTA 14.20 5R
30 30 0 769. QO130M200RB 769. PK18GTA 12.50 6R
40 40 0 931. QO140M200RB 931. PK23GTA 14.20 7R
Feed Thru
Main Circuit Breaker With Feed-Thru Lugs—Copper Bus—22,000 RMS Sym. Amperes Short Circuit Current Ratingh
125 6 12 6 $413. QO1612M125FTRB $413. #4–2/0 PK12GTA $10.50 3R
150 8 16 8 575. QO1816M150FTRB 575. #4–250 PK15GTA-L 23.30 6R
200 8 16 8 575. QO1816M200FTRB 575. #4–250 PK15GTA-L 23.30 6R
For additional information, reference Catalog #1100CT9901.
DE3A Discount
Schedule
LOAD CENTERS
www.SquareD.com
For the most up-to-date information
10
QO® Load Centers
Three Phase—Main Lugs, Main Circuit Breaker
Class 1130
© 2004 Schneider Electric
All Rights Reserved
6/7/04
QO312L125G
QO342MQ200
DE3 uDE3A sDE2 Discount
Schedule
For additional information, reference Catalog #1100CT9901.
Above listings thru 200 A mains rating meet Federal Specification W-P-115C as Type 1, Class 2.
aUL short circuit current rating depends on lowest interrupting rating of circuit breaker installed.
b25,000 RMS symmetrical amperes short circuit current rating maximum with Square D Type QDL main circuit breaker, or 22,000 RMS symmetrical amperes SCCR maximum
with back-fed Type QO-VH main circuit breaker, feeding QO 10,000 AIR branch circuit breakers.
cIncludes factory-installed back fed QO3100VH main circuit breaker.
d65,000 RMS Symmetrical Amperes Short Circuit Current Rating maximum with field-installed Square D
type QGL 65,000 AIR minimum main circuit breaker feeding QO and Q1 10,000 AIR minimum branch circuit breakers.
eSide hinge door device allow 114" on left side for door to open.
fPK23GTA and LK100AN.
gPK15GTA.
Three Phase (Order QO, QO-GFI, QO-AFI, QO-PL branch circuit breakers from pages 3 and 4.)
3 Phase 4 Wire 208Y/120 Vac, 3 Phase 4 Wire 240/120 Vac Delta and 3 Phase 3 Wire 240 Vac Delta—UL Listed.
Mains
Rating
(A)
Max.
Number
of 1-pole
QO
Breakers
Total Price
(Interior,
Box and
Cover)
Load Center
Box and Interior
Indoor Cover with Door
(Order Separately)
Main
Wire Size
AWG/kcmil
Equipment
Ground Bar Kit
(Order Separately)
Box No.
See
Pages
19, 20
Flush
Catalog No.
Surface
Catalog No. Price
Catalog Number Price Al Cu Catalog No. Priceu
I
N
D
O
O
R
Fixed Mains—Factory-installed Main Lugs—Copper Bus—65,000 RMS Symmetrical Amperes Short Circuit Current Rating a
60 3 $71.00 QO403L60NF/S $71.00 Cover Included With Load Center . . . #10–6 PK4GTA $7.20 13
125
12 246.10 QO312L125G 221.00 QOC16UF QOC16US $25.10u
#6–2/0 #6–2/0
Factory-incl.g. . . 6
20 339.10 QO320L125G 314.00 QOC24UF QOC24US 25.10uFactory-incl.g. . . 7
24 385.10 QO324L125G 360.00 QOC24UF QOC24US 25.10uFactory-incl.g. . . 7
200 18 353.00 QO318L200G 295.00 QOC30UF QOC30US 58.00u#6–250 #6–250 Factory-incl.f. . . 9
30 471.00 QO330L200G 413.00 QOC30UF QOC30US 58.00uFactory-incl.f. . . 9
225 42 635.00 QO342L225G 561.00 QOC42UF QOC42US 74.00u#6–300 #6–300 Factory-incl.f. . . 11
Convertible Mains—Factory-installed QDL Main Circuit Breaker—Copper Bus—25,000 RMS Symmetrical Amperes Maximum
Short Circuit Current Rating b
100 27 $705.00 QO327M100 c$647.00 QOC30UF QOC30US $58.00u#4–2/0 #4–2/0 PK15GTA $11.40 9
125 30 1287.00 QO330MQ125 d1226.00 QOC342MQF QOC342MQS 61.00 #4–300 #4–300 PK18GTA 12.50 12
150 30 1287.00 QO330MQ150d1226.00 QOC342MQF QOC342MQS 61.00 #4–300 #4–300 PK18GTA 12.50 12
42 1412.00 QO342MQ150d1351.00 QOC342MQF QOC342MQS 61.00 PK23GTA 14.20 12
200 30 1287.00 QO330MQ200d1226.00 QOC342MQF QOC342MQS 61.00 #4–300 #4–300 PK18GTA 12.50 12
42 1412.00 QO342MQ200d1351.00 QOC342MQF QOC342MQS 61.00 PK23GTA 14.20 12
225 42 1412.00 QO342MQ225d1351.00 QOC342MQF QOC342MQS 61.00 #4–300 #4–300 PK23GTA 14.20 12
R
A
I
N
P
R
O
O
F
Fixed Mains—Factory-installed Main Lugs—Copper Bus—65,000 RMS Symmetrical Amperes Short Circuit Current Rating ae
60 3 $118.00 QO403L60NRB $118.00
Cover Included
. . . #10–6 PK4GTA $7.20 10R
125 12 323.00 QO312L125GRB 323.00 #6–2/0 #6–2/0 Factory Incl.g. . . 3R
20 419.00 QO320L125GRB 419.00 Factory Incl.g. . . 4R
200 18 412.00 QO318L200GRB 412.00 #6–250 #6–250 Factory Incl.f. . . 6R
30 559.00 QO330L200GRB 559.00 Factory Incl.f. . . 6R
225 42 996.00 QO342L225GRB 996.00 #6–300 #6–300 Factory Incl.f. . . 8R
Convertible Mains—Factory-installed QDL Main Circuit Breaker—Copper Bus—25,000 RMS Symmetrical Amperes Maximum
Short Circuit Current Ratingbe
100 27 $790.00 QO327M100RB c$790.00
Cover Included
#4–2/0 #4–2/0 PK15GTA $11.40 6R
125 30 1431.00 QO330MQ125RB d1431.00 #4–300 #4–300 PK18GTA 12.50 14R
150 30 1431.00 QO330MQ150RBd1431.00 #4–300 #4–300 PK18GTA 12.50 14R
200 30 1431.00 QO330MQ200RB d1431.00 #4–300 #4–300 PK18GTA 12.50 14R
42 1555.00 QO342MQ200RBd1555.00 PK23GTA 14.20 14R
225 42 1555.00 QO342MQ225RBd1555.00 #4–300 #4–300 PK23GTA 14.20 14R
hWhen these 3-pole circuit breakers are used as the main circuit breaker of a three-phase load
center, the maximum AIR rating is 65,000 at 240 Vac and 100,000 at 208 Vac.
Three Phase Main Circuit Breakers
Field-installable alternate main circuit breakers for QO three phase main circuit breaker load
centers rated 70–225 A. Do not exceed the load center main rating.
Amperage 25k AIR 65k AIR 100k AIRh
70 QDL32070 QGL32070 QJL32070
80 QDL32080 QGL32080 QJL32080
90 QDL32090 QGL32090 QJL32090
100 QDL32100 QGL32100 QJL32100
110 QDL32110 QGL32110 QJL32110
125 QDL32125 QGL32125 QJL32125
150 QDL32150 QGL32150 QJL32150
175 QDL32175 QGL32175 QJL32175
200 QDL32200 QGL32200 QJL32200
225 QDL32225 QGL32225 QJL32225
Price $1189.00s$1628.00s$1864.00s
Three Phase Main Lug Kits
Field-installable main lugs for convertible three phase main circuit breaker load centers.
Main Lug
Amperage Rating Catalog Number Price Lug Wire Size
AWG/kcmil
125 QOL3125 $44.90 #6–2/0 Cu/Al
225 QOL3225 105.00 #6–300 Cu/Al
LOAD CENTERS
11
QO® Load Centers
Special Applications
Class 1130
© 2004 Schneider Electric
All Rights Reserved
6/7/04
www.SquareD.com
For the most up-to-date information
For additional information,
reference Catalog #1100CT9901.
Above listings thru 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
Order QO, QOT, QO-EPD, QO-GFI and QO-AFI Branch Circuit Breakers from pages 3 and 4.
Mains
Rating
(A)
Spaces
Max.
Number
Single
Pole
Circuitsa
Max.
Number
of Tandem
Circuit
Breakers
Load Centerb
Box , Interior, and Cover
Equipment
Ground Bar Kit
(Order Separately)
Main
Wire Size
AWG/kcmil
Box No.
See
page 19
Catalog Number Price Catalog No. Price Al Cu
I
N
D
O
O
R
Manufactured Housing 1 Phase—2 Wire 120 Vac—Main Lugs Only—CSA Certified
10,000 RMS Sym. Ampere Short Circuit Current Rating
30 c22
4
0QO2L30TTSd$33.90 Factory-installed #12–10 #14–10 1
50 2 2 QO24L50TTSe52.00 . . . #14–6 2
1 Phase—2 Wire 120 Vac—Main Circuit Breaker—CSA Certified—10,000 RMS Sym. Ampere Short Circuit Current Rating
30 3 5 2 QO35FM30TTF/S $55.00 Factory-installed f3
1 Phase—3 Wire 120/240 Vac—Main Lugs Only—CSA Certified—10,000 RMS Sym. Ampere Short Circuit Current Rating
70 2 4 2 QO24L70TSe$52.00
Factory
Installed
#12–3 #14–4 2
100
6126QO612L100TF/Sg57.00
#4–1
4
6126QO612L100DTF/Sg67.00 4
8168QO816L100TF/Sg91.00 4
8168QO816L100DTF/Sg106.00 4
Generator Panel 1 Phase—3 Wire 120/240 Vac—Factory-installed Main Circuit Breakers with Mechanical Interlock
10,000 RMS Sym. Amperes Short Circuit Current Rating
30 4 8 4 QO48M30DSGP $375.00 PK7GTA $7.80 #14–8 #14–8 4
60 4 8 4 QO48M60DSGP 375.00 PK7GTA 7.80 #8–2 #8–2 4
Load Center with Cover 1 Phase—3 Wire 120/240 Vac—UL Listed
Complete QO Load Center—Box, Interior & Combination Cover—in One Package
Convertible Mains—Factory-installed Main Lugs—65,000 RMS Sym. Amperes Short Circuit Current Ratinghi
QOM1 Main Frame Size—Convertible to Main Circuit Breaker (See page 7)—Copper Bus
125 A
12 12
24
20
0QO112L125GC $125.00 PK12GTA Incl. #6–2/0 6
12 12 QO11224L125GC 166.00 PK15GTA Incl. #6–2/0 6
20 0 QO120L125GC 189.00 PK15GTA Incl. #6–2/0 7
Convertible Mains—Factory-installed Main Lugs—65,000 RMS Sym. Amperes Short Circuit Current Ratinghi
QOM2 Main Frame Size—Convertible to Main Circuit Breaker (See page 7)—Copper Bus
150 A 30 30 0 QO130L150TC $301.00 PK23GTA & LK100AN Installed #6–250 9
200 A 30 40 10 QO13040L200GC 383.00 PK23GTA & LK100AN Incl. #6–250 9
Convertible Mains—Factory-installed Main Circuit Breaker—22,000 RMS Sym. Amperes Short Circuit Current Rating
QOM1 Main Frame Size—Convertible to Main Lugs (See page 8 or Lower Amperage Main Circuit Breaker (See page 7)—Copper Bus j
100 A
12 12
20
16
20
0QO112M100C $234.00 PK9GTA $8.90 #4–1/0 5
12 8 QO11220M100C 275.00 PK15GTA 11.40 #4–1/0 5
16 0 QO116M100C 263.00 PK12GTA 10.50 #4–1/0 6
20 0 QO120M100C 297.00 PK15GTA 11.40 #4–1/0 6
Convertible Mains—Factory-installed Main Circuit Breaker—22,000 RMS Sym. Amperes Short Circuit Current Rating
QOM2 Main Frame Size—Convertible to Main Lugs (See page 8 or Lower Amperage Main Circuit Breaker (See page 7)—Copper Busj
150 A 20 30 10 QO12030M150C $562.00 PK18GTA $12.50 #4–250 9
30 30 0 QO130M150C 580.00 PK18GTA 12.50 #4–250 9
200 A
20 40 20 QO12040M200C 562.00 PK23GTA 14.20 #4–250 9
30 30 0 QO130M200C 597.00 PK18GTA 12.50 #4–250 9
30 40 10 QO13040M200C 649.00 PK23GTA 14.20 #4–250 9
40 40 0 QO140M200C 758.00 PK23GTA 14.20 #4–250 10
Accessories
kOne tap kit required for each riser wire.
lWhen used with B300 bolt-on hubs.
Auxiliary Gutter
UL Listed For Use With Standard 1Ø an 3Ø Load Centers For Riser Applications k. For Auxiliary Gutter-Load
Center Compatibility, see Catalog 1100CT9901.
Catalog
Number Price Cover Conduit
Riser Size Width Height Depth
SDAG26 $225. Flush 134, 2, 212 or l 3 13.50 26.12 3.75
Tap Kits 120/240 Vac—UL Listed For Use With Auxiliary Gutters SDAG26
Catalog
Number Price
Use With
Auxiliary
Gutter
Catalog
Number
Riser Wire Tap Off Wire
Lug Type Al/Cu Wire Size Lug Type Al/Cu Wire Size
SDGT30020 $54.00 SDAG26 Mechanical
(Included) (2) #6–300 kcmil Mechanical
(Included) (1) #6–2/0
SDGT300300 80.00 SDAG26 Mechanical
(Included) (2) #6–300 kcmil Mechanical
(Included) (1) #6–300 kcmil
SDGT300C10C 33.10 SDAG26
Anderson
#VCEL030516H1
(Not included)
(2) #4–300 kcmil
Anderson
#VCEL02114S1
(Not Included)
(1) #8–1/0
SDGT300C300C 46.90 SDAG26
Anderson
#VCEL030516H1
(Not included)
(2) #4–300 kcmil
Anderson
#VCEL030516H1
(Not included)
(1) #4–300 kcmil
QOGL20
Grounding
Te r minals
27.10 SDAG26 Mechanical
(Included) (2) #6–2/0 . . . . . .
aMaximum number of single pole branch circuits utilizing QO and/or QOT
circuit breakers.
bOrder F for flush device or S for surface device.
cMains rating 25 A when Al wire is used.
dWill not accept QWIK-GARD® QO-GFI circuit breaker.
eUse #10 maximum size wire for GFI circuit breakers.
fMain circuit breaker is a field-installed standard QO single pole circuit
breaker. Order separately from page 3.
g70 A max. branch circuit breaker and 70 A max. back fed main circuit
breaker.
hUL short circuit current rating depends on lowest interrupting rating of
circuit breaker installed.
iUL Listed 5000 A short circuit current rating for corner grounded Delta
systems. Use QO-H circuit breakers only.
j22,000 AIR main circuit breaker UL Listed for use ahead of QO, QOT and
QO-PL 10,000 AIR branch circuit breakers to permit their application on
systems with up to 22,000 A available fault current.
DE3A Discount
Schedule
LOAD CENTERS
www.SquareD.com
For the most up-to-date information
12
QO® & HOMELINE® Load Centers
Special Applications
Class 1130, 1170
© 2004 Schneider Electric
All Rights Reserved
6/7/04
For additional information, reference Catalog #1100CT9901.
Above listings thru 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
aMaximum number of single pole branch circuits utilizing QO and/or QOT circuit breakers.
Above listings thru 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
aMaximum number of single pole branch circuits utilizing QO and/or QOT circuit breakers.
bUL short circuit current rating depends on lowest interrupting rating of circuit breaker installed.
cUL Listed 5000 A short circuit current rating for corner grounded Delta systems. Use QO-H circuit breakers only.
Panelboard-style Covers for Riser Panels
Mono-Flat® Front available for riser panels as an alternative to standard
load center cover listed above. Provides a low-profile, aesthetically
pleasing solution for high-traffic areas in upscale multi-family
applications. Deadfront included. Lock kit not provided. d
dOrder catalog number PK4FL for field installable lock kit.
Load Center Value Pack
1 Phase, 3 Wire—120/240 Vac—UL Listed—Convertible Mains—Factory-installed Main Circuit Breaker
Complete Load Center (Box, Interior and Cover) and Selected Branch Circuit Breakers
Mains
Rating
(A)
Spaces
Max.
Number
Single
Pole
Circuitsa
Max.
Number
of Tandem
Circuit
Breakers
Load Center
Box , Interior, Cover and Branch Circuit Breakers
Equipment
Ground Bar Kit
(Order Separately)
Main
Wire Size
AWG/kcmil
Al/Cu
Box No.
See
Pages
19,
20Catalog No. Included Load Center/Circuit Breakers Price Catalog No. Price
I
N
D
O
O
R
QO—Copper Bus—Order extra QO, QOT, QO-EPD, QO-GFI, QO-AFI branch circuit breakers from pages 3 and 4.
200 30 40 10 QOVP1 (1) QO13040M200C, (5) QO120 $735.00 PK23GTA $14.20 #4–250 9
100 32 32 0 QOVP2 (1) QO132M100C, (5) QO120 559.00 PK18GTA 12.50 #4–2/0 8
HOMELINE—Order extra HOM, HOMT, HOM-GFI, HOM-AFI branch circuit breakers from page 15.
200 30 40 10 HOMVP1 (1) HOM3040M200TC, (5) HOM120, (1) HOM230 722.00 Included . . . #4–250 10
200 30 40 10 HOMVP2 (1) HOM3040M200TC, (5) HOM115, (1) HOM230 722.00 Included . . . #4–250 10
100 20 20 0 HOMVP4 (1) HOM20M100C, (5) HOM115 352.00 PK15GTA 11.40 #4–2/0 8
100 20 20 0 HOMVP5 (1) HOM20M100C, (5) HOM120 352.00 PK15GTA 11.40 #4–2/0 8
150 30 30 0 HOMVP12 (1) HOM30M150C, (5) HOM120, (1) HOM230 655.00 PK23GTA 14.20 #4–250 10
200 30 40 10 HOMVP9 (1) HOM3040M200TC, (6) HOM115, (6) HOM120, (1) HOM230, (1) HOM250 885.00 Included . . . #4–250 10
200 30 40 10 HOMVP14 (1) HOM3040M200TC, (12) HOM120, (1) HOM230, (1) HOM250 885.00 Included . . . #4–250 10
200 30 40 10 HOMVPL1 (1) HOM3040L200TC, (6) HOM115, (6) HOM120, (1) HOM230, (1) HOM250 641.00 Included . . . #4–250 10
125 12 24 12 HOMVPL2 (1) HOM1224L125TC, (5) HOM120 235.00 Included . . . #6–2/0 6
HOMELINE—Rainproof
200 20 40 20 HOMVPRB1 (1) HOM2040M200RB, (6) HOM115, (6) HOM120, (1) HOM230, (1) HOM250 835.00 PK23GTA 14.20 #4–250 6R
Riser
1 Phase—2 Wire 120/240 Vac—Offset Interior Wide Gutter—50 A Maximum Branch Circuit Breakerbc
Mains
Rating
(A)
Spaces
Max.
Number
Single
Pole
Circuitsa
Max.
Number
of Tandem
Circuit
Breakers
Load Center Box and Interior Load Center Cover
Equipment
Ground Bar Kit
(Order Separately)
Main
Wire Size
AWG/kcmil
Box No.
See
page 19
Catalog Number Price Catalog Number Price Catalog No. Price Al Cu
I
N
D
O
O
R
Convertible Mains—Factory-installed Main Lugs—65,000 RMS Sym. Amperes Short Circuit Current Rating
QOM1 Main Frame Size—Convertible to Main Circuit Breaker (See page 7)—Copper Bus
125 12 24 12 QO11224L125WG $225. QOC20UFWG $35. PK15GTA $11.40 #6–2/0 14
125 20 30 10 QO12030L125WG 310. QOC20UFWG 35. PK15GTA 11.40 #6–2/0 14
Fixed Mains—Factory-installed Main Lugs—65,000 RMS Sym. Amperes Short Circuit Current Rating
Copper Bus
200 30 40 10 QO13040L200WG 467. QOC30UFWG 68. PK23GTA 14.20 #4–250 23
Mains Rating of
Load Center
(A)
Catalog Number Price
125 NQC20FWG $78.
200 NQC30FWG 120.
DE3A Discount
Schedule
LOAD CENTERS
13
QO® Load Centers
Accessories
Class 1130
© 2004 Schneider Electric
All Rights Reserved
6/7/04
www.SquareD.com
For the most up-to-date information
QO Load Center Accessories
Description Catalog Number Price Schedule
Retaining Kit Secures circuit breaker to interior when used as a back-fed main. For QO612L100F/S, RB,
QO612L100DF/S, QO816L100F/S, RB, QO816L100DF/S and QO148L125GF/S, GRB load centers . . . . . . . . . . . . . . PK2MB 4.80 DE3A
Secures circuit breaker to interior when used as a back-fed main. For 3Ø Load Centers . . . . . . . . . . . . . . . . . . . . . . . . . PK3MB 9.80 DE3A
Secures circuit breaker to interior when used as a back-fed main for 2-pole QO 150–200 A circuit breakers. . . . . . . . . . PK5RK 9.80 DE3A
Secures ONE circuit breaker with or without electrical accessories to right side of interior when used as a back-fed main.
For 1Ø 100–125 ampere convertible main load centers. Series S01 and S02. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PK4MB2LA 9.80 DE3A
Secures ONE circuit breaker with or without electrical accessories to right side of interior when used as a back-fed main.
For 1Ø 150–225 ampere convertible main load centers. Series S01 and S02. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PK4MB2HA 9.80 DE3A
Manual Transfer
Equipment Kit
For interlocking the handles of two 2-pole or one 2-pole and one 1-pole QO and Q1 circuit breakers mounted
side-by-side so that only one circuit breaker can be “ON’ at a time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
QO2DTI
16.60
DE2E
QO2DTI mechanical interlock attachment with retaining kits for securing two adjacent back-fed circuit
breakers in dual power supply applications. Can be used with (2) 2-poles or (1) 2-pole and (1) 1-pole QO
circuit breakers in QO816L100 load centers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
QO2DTIM
42.00
DE2E
Secures TWO 2-pole circuit breakers to right side of interior when used as back-fed mains, a QO2DTI Kit included for
back-up power supply applications. For 1Ø 100–125 ampere convertible main load centers. Series S01 and S02. . . . . . PK4DTIM4LA 68.00 DE3A
Secures TWO 2-pole circuit breakers to right side of interior when used as back-fed mains, a QO2DTI Kit included for
back-up power supply applications. For 1Ø 150–225 ampere convertible main load centers. Series S01 and S02. . . . . . PK4DTIM4HA 68.00 DE3A
Secures TWO 2-pole circuit breakers to left side of interior when used as back-fed mains, a QO2DTI Kit included for
back-up power supply applications. For 1Ø 100–125 ampere convertible main load centers. Series S01 and S02. . . . . . PK4DTIM4LAL 68.00 DE3A
Generator Circuit Breaker
Interlock Kit
For use on “G” and “S” Series NEMA 1 and “G” and “S1” Series NEMA 3R load centers. Interlocks a QOM2 2-pole main
circuit breaker of a load center (150–225 A) with a QO 2-pole (15–125 A) branch circuit breaker. Includes a retaining kit. QOCGK2 70.00 DE3A
For use on “S2” Series NEMA 3R load centers. Interlocks a QOM2 2-pole main circuit breaker of a load center
(150–225 A) with a QO 2-pole (15–125 A) branch circuit breaker. Includes a retaining kit.. . . . . . . . . . . . . . . . . . . . . . . . . QORBGK2 70.00 DE3A
Miscellaneous
Cover Sealing Strap: Provides means of sealing trim mounting screws on QO load center covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QO1SE 2.40 DE3A
Surge Arresters: For use on 1Ø3W, 150 Vac maximum. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SDSA1175 61.00 DE1B
For use on 3Ø4W, 650 Vac maximum. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SDSA3650 165.00 DE1B
QO SURGEBREAKER CULUS Listed Secondary Surge Arrester 150 Vac line-to-ground maximum. QO2175SB 106.00 DE1B
HOMELINE SURGEBREAKER CULUS Listed Secondary Surge Arrester 150 Vac line-to-ground maximum. HOM2175SB 106.00 DE1B
Surge Arrester Mounting Kit: UL Listed for mounting SDSA1175 surge arrester into ground bar mounting holes on 1Ø convertible
main circuit breaker load centers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QOSAMK 7.60 DE3A
PK3MB
QOSAMK
PK2MB
QO2DTI
PK4DTIM4HA
QO2DTI Installed
OFF
ON
OFF
ON
ON
OFF
ON
OFF
135
642
QOCGK2 Installed
LOAD CENTERS
www.SquareD.com
For the most up-to-date information
14
QO® and HOMELINE® Load Centers
Accessories
Class 1130, 6610
© 2004 Schneider Electric
All Rights Reserved
6/7/04
aQO612L100DF/S, QO816L100DF/S, QO612L100DFCU/SCU, QO816L100DFCU/SCU and QO403L60NF/S DO NOT have provisions for field-installed lock.
QO Load Center Accessories
Description Catalog Number Price Schedule
Filler Plates Fills opening in covers if twistout is removed in error . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . QOFP $2.40 DE3A
Fills main circuit breaker opening in convertible load center covers . . . . . . . . . . . . 100–125 A. . . . . . . . . . . . . . . . . . . . . . . QOM1FP 13.50 DE3A
Fills main circuit breaker opening in convertible load center covers . . . . . . . . . . . . 150–225 A. . . . . . . . . . . . . . . . . . . . . . . QOM2FP 13.50 DE3A
Fills main circuit breaker opening in three phase load center covers (S01 and S02 Series). . . . . . . . . . . . . . . . . . . . . . . . KFP 13.50 DE3A
Fills main circuit breaker opening in “Q” style three phase load center covers (S03 Series). . . . . . . . . . . . . . . . . . . . . . . . Q2FP 13.50 DE3A
Lock Kits Use with convertible mains, 1Ø and 3Ø 100–225 A, and fixed mains, 3Ø 125–225 A indoor load centers . . . . . . . . . . . PK6FL a62.00 DE3A
Use with 300 and 400 ampere indoor load centers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PK4FL 60.00 PE1A
Neutral / Ground Lugs Field-installed for #12 to 2 Al or #14 to 4 Cu wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LK70AN 6.70 DE3A
Field-installed for #6 to 2/0 Al/Cu wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LK100AN 7.20 DE3A
Field-installed for #14 to 2/0 Al/Cu wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LK125AN 14.70 DE3A
Field-installed for #2 to 3/0 Al/Cu wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . LK150AN 21.60 DE3A
Field-installed for #4 to 300 kcmil Al/Cu wire. Use in Series S, 150–225 A QO or HOM load center . . . . . . . . . . . . . . . . LK225AN 22.10 DE3A
Ground Bar Kits Standard PK15GTA with a #1 to 4/0 Al/Cu Lug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PK15GTAL 23.30 DE3A
Standard PK18GTA with a #1 to 4/0 Al/Cu Lug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PK18GTAL 25.20 DE3A
Standard PK23GTA with a #1 to 4/0 Al/Cu Lug . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PK23GTAL 27.10 DE3A
Insulator Kit for PK7GTA thru PK27GTA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PKGTAB 29.20 DE3A
Handle Padlock Attachment:For padlocking main circuit breakers in convertible load centers, “OFF’ . . . . . . . . 50–125 A, QOM1 Frame Size . . . . . QOM1PA 7.30 DE2E
100–225 A, QOM2 Frame Size . . . . . QOM2PA 7.30 DE2E
HOMELINE Load Center Accessories
Description Catalog Number Price Schedule
Handle Padlock Attachment: For padlocking main circuit breakers in convertible load center, “OFF” 50–125 A QOM1PA $7.30 DE2E
100–225 A QOM2PA 7.30 DE2E
Filler Plates Fills opening in covers if twistout is removed in error HOMFP 2.10 DE3C
Fills main circuit breaker opening in convertible load centers 100–125 A QOM1FP 13.50 DE3A
150–225 A QOM2FP 13.50 DE3A
Neutral Lugs Field-installed for #14 to 2 Al or #14 to 4 Cu wire LK70AN 6.70 DE3B
Field-installed for #6 to 2/0 Al/Cu wire LK100AN 7.20 DE3B
Field-installed for #14 to 2/0 Al/Cu wire LK125AN 14.70 DE3B
Field-installed for #4 to 300 kcmil Al/Cu wire. Use in SeriesS, 150–225 A QO or HOM load center LK225AN 22.10 DE3A
Miscellaneous
Retaining Kit: Secures circuit breaker to interior when used as a back-fed main.
For HOM612L100F/S, RB and HOM48L125GC, GRB load centers.
HOM1RK 4.30 DE3C
Secures ONE circuit breaker right side of interior when used as a back-fed main. For 100–125 ampere convertible main
load centers, Series S01 and S02
HOM4RK2LA 9.80 DE3C
Secures ONE circuit breaker right side of interior when used as a back-fed main. For 150–225 ampere convertible main
load centers, Series S01 and S02
HOM4RK2HA 9.80 DE3C
Secures circuit breaker to interior when used as a back-fed main for 2-pole 150–200 ampere circuit breakers HOM5RK 9.80 DE3C
Lock Kit: Use with convertible indoor load center covers(Series S-1) PK6FL 62.00 DE3A
Generator Circuit
Breaker Interlock Kit
For use on “S” Series NEMA 1 and “S1” Series NEMA 3R load centers. Interlocks a QOM2 2-pole main circuit breaker
of a load center (150–225 A) with a HOMELINE 2-pole 15–125 A) branch circuit breaker. HOMCGK2 70.00 DE3D
For use on “S2” Series NEMA 3R load centers. Interlocks a QOM2 2-pole main circuit breaker of a load center
(150–225 A) with a HOMELINE 2-pole (15–125 A) branch circuit breaker. HOMRBGK2 70.00 DE3D
PK6FL
PK4FL
PKGTAB
QOFP
bIMPORTANT: Will fit only Class 6610 Series A testers and Catalog Number 5008, Series B testers. Will not fit 5008 Pre-Series B testers. Leads must be
replaced as a unit. Replacement of individual lead components must not be attempted.
Voltage Testers
Solenoid Type with polarity indication and slotted receptacles for holding prods. UL and CSA Listed.
Description Type Price Schedule
The Voltage Tester 120-240-480-600 Vac 50/60 Hz; 120-240-600 Vdc 6610 VT1 $67.00 DE3B
Same as VT-1 except with fused leads 6610 VT1S 74.00 DE3B
Deluxe Simulated Leather Carrying Case 6610 L2 39.30 DE3B
Replacement Polarity Indication Cap b6610 PC1 8.00 DE3B
Replacement Leads b6610 P1 25.70 DE3B
Fused Replacement Leads b6610 P1S 35.50 DE3B
Wiggy® Voltage Tester
LOAD CENTERS
15
HOMELINE® Circuit Breakers
Class 750, 751, 911
© 2004 Schneider Electric
All Rights Reserved
6/7/04
www.SquareD.com
For the most up-to-date information
DE3D jDE3C vDE2E Discount
Schedule
Plug-On Circuit Breakers—UL Listed 10,000 Amperes
RMS Symmetrical Interrupting Rating (AIR)
The Square D HOMELINE circuit breakers are in a 1-inch wide industry-
standard format for 1-pole circuit breakers. They are designed to plug
into HOMELINE load centers that are available from 4 to 42 circuits.
The Square D exclusive QWIK-OPEN® mechanism is standard on all
15 A and 20 A circuit breakers with a trip reaction within 1/60th of a
second.
aUL Listed as SWD (switching duty) rated. Suitable for switching 120 Vac fluorescent lighting
loads.
bUL Listed as HACR type for use with air conditioning, heating and refrigeration equipment
having motor group combinations and marked for use with HACR type circuit breakers.
cRequires four spaces (#1–300 kcmil Al/Cu). Use only in single phase panel rated 150 A or
greater.
HOM
Ampere
Rating
1-pole—120/240 Vac 2-pole—120/240 Vac
Common Trip
Catalog Number Price Catalog Number Price
10,000 Amperes RMS—UL Listed Interrupting Rating
15 HOM115 ab $17.50 HOM215 b$40.30
20 HOM120 ab 17.50 HOM220 b40.30
25 HOM125 b17.50 HOM225 b40.30
30 HOM130 b17.50 HOM230 b40.30
35 . . . . . . HOM235 b40.30
40 HOM140 b17.50 HOM240 b40.30
45 . . . . . . HOM245 b40.30
50 HOM150 b17.50 HOM250 b40.30
60 . . . . . . HOM260 b40.30
70 . . . . . . HOM270 b82.00
80 . . . . . . HOM280 b112.00
90 . . . . . . HOM290 b112.00
100 . . . . . . HOM2100 b112.00
110 . . . . . . HOM2110 b246.00
125 . . . . . . HOM2125 b246.00
150 . . . . . . HOM2150BB bc 285.00
175 . . . . . . HOM2175BB bc 285.00
200 . . . . . . HOM2200BB bc 285.00
HOM-HM
High magnetic trip circuit breakers are recommended for applications where high initial inrush
current may occur.
Amperes 1-pole—120/240 Vac 2-poles
Catalog Number Price . . .
15 HOM115HMb$18.40 . . .
20 HOM120HMb18.40 . . .
HOM-AFI
HOMELINE Arc Fault Circuit Interrupters—Provide overload and short circuit protection, plus arc
fault protection in accordance with UL 1699.
Ampere Rating Poles 120 Vac Catalog Number Price
15 1 HOM115AFIb$150.00
20 1 HOM120AFIb150.00
HOM-GFI
HOM-GFI circuit breakers provide overload and short circuit protection, combined with Class A
ground fault protection. Class A denotes a ground fault circuit interrupter that will trip when a fault
current to ground is 6 milliamperes or more.
Ampere
Rating
1-pole—120 Vac 2-pole—120/240 Vac
Common Trip
1 Space Required 2 Spaces Required
Catalog Number Price Catalog Number Price
10,000 AIR
15 HOM115GFI $141.00 HOM215GFI $275.00
20 HOM120GFI 141.00 HOM220GFI 275.00
30 . . . . . . HOM230GFI 275.00
40 . . . . . . HOM240GFI 275.00
50 . . . . . . HOM250GFI 275.00
HOM-EPD HOMELINE Equipment Protection Device—Circuit Breakers with 30 mA
Equipment Ground Fault Protection (UL Listed)
Amperes 1-pole—120 Vac 2-pole—120/240 Vac
Common Trip
Catalog Number Price Catalog Number Price
10,000 AIR
15 HOM115EPD $249.00 HOM215EPD $440.00
20 HOM120EPD 249.00 HOM220EPD 440.00
25 . . . . . . HOM225EPD 440.00
30 . . . . . . HOM230EPD 440.00
40 . . . . . . HOM240EPD 440.00
50 . . . . . . HOM250EPD 440.00
HOMT Tandem Circuit Breakers
Ampere Rating d1-pole Tandem—120/240 Vac (One Space Required)
Catalog No. Price
10,000 AIR
15 and 15 HOMT1515 b$34.90
15 and 20 HOMT1520 b34.90
20 and 20 HOMT2020 b34.90
30 and 15 HOMT3015 b34.90
30 and 20 HOMT3020 b34.90
d15–20 A tandem or quad tandem circuit breakers are suitable for use with 60°C or 75°C
conductors. 25–50 A tandem or quad tandem circuit breakers are suitable for use with 75°C
conductors only.
e15–30 A circuit breakers are suitable for use with 60°C or 75°C conductors. 40–125 A circuit
breakers are suitable for use with 75°C conductors.
f50–125 A QOM1 frame size; 100–225 A QOM2 frame size.
HOMT Quad Tandem Circuit Breakers
Ampere Rating d2-pole Tandem—120/240 Vac (Two Spaces Required)
1P 2P Catalog No. Price
10,000 AIR
(2) 15 15 HOMT1515215b$80.00
(2) 15 20 HOMT1515220b80.00
(2) 15 25 HOMT1515225b80.00
(2) 15 30 HOMT1515230b80.00
(2) 15 40 HOMT1515240b80.00
(2) 15 50 HOMT1515250b80.00
(2) 20 20 HOMT2020220b80.00
(2) 20 25 HOMT2020225b80.00
(2) 20 30 HOMT2020230b80.00
(2) 20 40 HOMT2020240b80.00
(2) 20 50 HOMT2020250b80.00
Typical catalog number (e.g. HOMT 1515230) represents two single-pole, outer poles (two 15 A
1P CBs) and one 2-pole inner circuit breaker with common trip (one 30 A 2P CB).
HOM 1-pole HOM 2-pole HOMT
1-pole
HOMT Quad
Breaker
1 Space
Required
2 Spaces Required 1 Space
Required
2 Spaces Required
HOM 1-pole
AFI
(Arc Fault
Circuit
Interrupter)
HOM 1-pole GFI
(With Ground
Fault Circuit
Interrupter)
HOM 2-pole GFI
(With Ground
Fault
Circuit Interrupter)
HOM2200BB
Branch
Breaker
2 Spaces
Required
4 Spaces
Required
Circuit Breaker Wire Sizese
Breaker Type Ampere Rating Wire Size (AWG/kcmil)
Aluminum Copper
HOM 15–30 #14–8 #14–8 or (2) #14–10
1-pole 40–50 #8–2 #8–2
HOM
2-pole
15–30 #14–8 #14–8 or (2) #14–10
35–70 #8–2 #8–2
80–125 #4–2/0 #4–2/0
150–200 #4–300 #4–300
HOMT and Quad 15–30 #14–8 #14–8
Quad Only 40–50 #6–#12 #6–#14
HOM-GFI - 1-pole 15–20 #14–10 #14–10
HOM-GFI - 2-pole 15–50 #12–4 #14–6
Accessories
Description Catalog No. Price
HANDLE ATTACHMENTS
Handle Tie: Converts any two adjacent 120/240 Vac
single HOM breakers to independent trip
2-pole HOM1HT $2.30j
Handle Tie: Converts any two adjacent 120/240 Vac
single-pole side-by-side HOMT breakers to independent
trip 2-pole HOMTHT 2.50j
Handle Clamp: Clamp for holding HOM single-pole handle in “ON’
or “OFF’’ position QO1LO 2.50v
Handle Blocking Device: Attaches to standard HOM 2-pole circuit
breakers for holding the handle in the “OFF” position HOM2HBD 7.10j
Handle Padlock Attachment: For padlocking 1-pole
Standard HOM breakers in “ON’’ or “OFF’ position. HOM1PA 6.60j
Handle Padlock Attachment: For padlocking 2-pole
Standard HOM breakers in “ON’’ or “OFF’ position
15–70 A HOM2PALA 6.60j
80–125 A HOM2PAHA 6.60j
150–200 A HOM2PAVHA 33.60j
Handle Padlock Attachment: For padlocking center
poles of Homeline Quad breakers in “OFF” position. HOMQPA 6.60
Handle Padlock Attachment: For padlocking main
circuit breakers in convertible load center, “OFF”
50–125 A QOM1PAf7.20v
100–225 A QOM2PAf7.20v
SUB-FEED LUGS
125 A 2-pole plug-on—2 spaces required HOML2125 31.70
225 A 2-pole plug-on—4 spaces required HOML2225c197.00
1 Space
Required
1 Space
Required
LOAD CENTERS
www.SquareD.com
For the most up-to-date information
16
HOMELINE® Load Centers
Series Rating
Class 1170
© 2004 Schneider Electric
All Rights Reserved
6/7/04
The rating of the load center is equal to the lowest interrupting rating of any circuit breaker installed or combination series connected circuit breaker.
Additional or replacement circuit breakers MUST have an interrupting and voltage rating equal to or greater than that of the circuit breaker with the lowest
interrupting and voltage rating presently installed. See load center interior for circuit breaker types.
a100 Amperes maximum branch circuit breaker in load centers with 125 A maximum mains rating.
bSee circuit breaker for voltage and interrupting rating.
cHOM includes suffixes: GFI and AFI.
Short Circuit Current Rating
Maxium
Short Circuit
Current Rating
(RMS Symmetrical)
Load Center
Voltage Rating
240 Vac Max.
Remote Square D
Circuit Breaker
Integral Square D
Circuit Breaker Square D Branch Circuit Breaker
Catalog
Designation
b
Current Rating
Amperes Max.
Catalog
Designation
b
Current
Rating
Amperes Max.
Catalog
Designation
bc
Current Rating Amperes
Systems Voltage 1-pole 2-pole
10,000 120/240 Vac, 1 Phase 3 Wire …………
HOM 15–50 15–200 a
HOMT 15–30 15–50
Series Combination Short Circuit Current Rating
22,000 120/240 Vac, 1 Phase 3 Wire
……
QOM-VH
225
HOM 15–50 15–200 a
HOMT 15–30 15–50
QO-VH 200 HOM 15–50 15–200 a
HOMT 15–30 15–50
42,000 120/240 Vac, 1 Phase 3 Wire QOH 125 HOM 15–50 15–200 a
HOMT 15–30 15–50
25,000 120/240 Vac, 1 Phase 3 Wire QD 225 HOM 15–50 15–200 a
HOMT 15–30 15–50
65,000 120/240 Vac, 1 Phase 3 Wire QG 225 HOM 15–50 15–200 a
HOMT 15–30 15–50
100,000 120/240 Vac, 1 Phase 3 Wire QJ 225 HOM 15–50 15–200 a
HOMT 15–30 15–50
LOAD CENTERS
17
HOMELINE® Load Centers
Indoor—Single Phase, Main Lug, Main Circuit Breaker
Class 1170
© 2004 Schneider Electric
All Rights Reserved
6/7/04
www.SquareD.com
For the most up-to-date information
Above listings thru 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
aMaximum number of single pole branch circuits utilizing HOM and/or HOMT circuit breakers.
bC at end of catalog number indicates combination flush/surface cover included with device.
cF/S at end of catalog number indicates to order F for flush device or S for surface device. The cover does not have a door.
dHOM-GFI branch circuit breaker is limited to number 10 maximum wire.
e70 A maximum back feed main circuit breaker.
fSupplied with feed-thru lugs.
Single Phase Three Wire—120/240 Vac—UL Listed—10,000 RMS Sym. Amperes Short Circuit Current Rating
Mains
Rating
(A)
Spaces
Max.
Number
Single
Pole
Circuitsa
Max.
Number of
Tandem
Circuit
Breakers
Load Center
Box, Interior and Coverb
Main Wire Size
AWG/kcmil
Equipment Ground Bar Kit
(Order Separately) Box No.
See
page 19
Catalog Number Price
(DE3C) Al Cu Catalog Number Price
(DE3A)
I
N
D
O
O
R
Main Lugs—Order HOM, HOMT, HOMGFI and HOMAFI Circuit Breakers from page 15
Factory-installed Fixed Main Lugs
70 2 4 2 HOM24L70F/S cd $39.20 #12–3 #14–4 PK3GTA1 $7.60 2
100 6 12 6 HOM612L100F/S ce 52.00 #8–1 PK7GTA 7.80 4
125 4 8 4 HOM48L125GC 57.00 #12–2/0 #14–2/0 PK7GTA Factory-included 21
Convertible Mains—Factory-installed Main Lugs
QOM1 Main Frame Size—Convertible to 22,000 AIR Main Circuit Breaker (See page 18)
125
8168HOM816L125C 88.00
#6–2/0
PK15GTA 11.40 6
8168HOM816L125TC 100.00 Factory-installed . . . 6
12 12 0 HOM12L125C 116.00 PK15GTA 11.40 6
12 24 12 HOM1224L125TC 136.00 Factory-installed . . . 6
16 24 8 HOM1624L125C 173.00 PK15GTA 11.40 8
20 20 0 HOM20L125C 158.00 PK15GTA 11.40 8
20 24 4 HOM2024L125TC 192.00 Factory-installed . . . 8
24 24 0 HOM24L125TC 229.00 Factory-installed . . . 8
Convertible Mains—Factory-installed Main Lugs
QOM2 Main Frame Size—Convertible to 22,000 AIR Main Circuit Breaker (See page 18)
150 30 30 0 HOM30L150C 250.00 #6–250 PK23GTA 14.20 10
200
16 32 16 HOM1632L200TC 238.00
#6–250 Factory-installed . . .
9
16 32 16 HOM1632L200TCFTf383.00 10
20 40 20 HOM2040L200TC 278.00 9
200
30 30 0 HOM30L200C 280.00
#6–250
PK23GTA 14.20 10
30 30 0 HOM30L200TC 309.00 Factory-installed . . . 10
30 40 10 HOM3040L200TC 319.00 Factory-installed . . . 10
40 40 0 HOM40L200C 412.00 PK23GTA 14.20 12
225 42 42 0 HOM42L225C 488.00 #6–250 PK23GTA 14.20 12
Main Circuit Breaker—22,000 RMS Sym. Amperes Short Circuit Current Rating
Convertible Mains—Factory-installed Main Circuit Breaker
QOM1 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See page 18)
100
8168HOM816M100C $210.00 #6–1 PK15GTA 11.40 5
8168HOM816M100TC 222.00 #6–1 Factory-installed . . . 5
12 12 0 HOM12M100C 196.00 #4–2/0 PK15GTA 11.40 6
12 24 12 HOM1224M100TC 256.00 #4–2/0 Factory-installed . . . 6
20 20 0 HOM20M100C 264.00 #4–2/0 PK15GTA 11.40 8
24 24 0 HOM24M100C 342.00 #4–2/0 PK15GTA 11.40 8
30 30 0 HOM30M100C 448.00 #4–2/0 PK23GTA 14.20 10
125
12 24 12 HOM1224M125C 404.00
#4–2/0
PK15GTA 11.40 6
12 24 12 HOM1224M125TC 413.00 Factory-installed . . . 6
24 24 0 HOM24M125C 473.00 PK15GTA 11.40 8
30 30 0 HOM30M125C 541.00 PK23GTA 14.20 10
Convertible Mains—Factory-installed Main Circuit Breaker
QOM2 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See page 18)
150
16 32 16 HOM1632M150TC 424.00
#4–250
Factory-installed . . . 9
20 30 10 HOM2030M150TC 500.00 Factory-installed . . . 9
30 30 0 HOM30M150C 517.00 PK23GTA 14.20 10
200
12
16
20
20
24
32
40
40
12
16
20
20
HOM1224M200TC
HOM1632M200TC
HOM2040M200C
HOM2040M200TC
381.00
450.00
474.00
509.00 #4–250
Factory-installed
Factory-installed
PK23GTA
Factory-installed
. . .
. . .
14.20
. . .
9
9
9
9
30 30 0 HOM30M200C 532.00 PK23GTA 14.20 10
30 40 10 HOM3040M200TC 594.00 Factory-installed . . . 10
40 40 0 HOM40M200C 679.00 PK23GTA 14.20 12
42 42 0 HOM42M200C 729.00 PK23GTA 14.20 12
225 42 42 0 HOM42M225C 744.00 #4–250 PK23GTA 14.20 12
Universal Mains—No Factory-installed Main Circuit Breaker or Main Lugs
QOM2 Main Frame Size—Field-install 22,000 AIR Main Circuit Breaker or Main Lugs (See page 18)
200
16 32 16 HOM1632U200TC 195.00
#4–250
Factory-installed . . . 9
20 40 20 HOM2040U200TC 238.00 Factory-installed . . . 9
30 40 10 HOM3040U200TC 353.00 Factory-installed . . . 10
For additional information, reference Catalog #1100CT9901.
DE3A DE3C Discount
Schedule
LOAD CENTERS
www.SquareD.com
For the most up-to-date information
18
HOMELINE® Load Centers
Rainproof—Single Phase, Main Lug, Main Circuit Breaker
Class 1170
© 2004 Schneider Electric
All Rights Reserved
6/7/04
Above listings thru 200 A mains rating meet Federal Specification W-P-115c as Type 1, Class 2.
aMaximum number of single pole branch circuits utilizing HOM and/or HOMT circuit breakers.
bHOM-GFI branch circuit breaker is limited to number 10 maximum wire.
cSide hinge door device allow 114" on left side for door to open.
d22,000 AIR main circuit breaker UL Listed for use ahead of HOM and HOMT 10,000 AIR
branch circuit breakers to permit their application on systems with up to 22,000 A available
fault current.
eRated 200 A when using copper wire. Reference NEC® Tab le 310.15(B)(6) when using
Al wire.
Single Phase Three Wire—120/240 Vac—UL Listed—10,000 RMS Sym. Amperes Short Circuit Current Rating
Main Lugs—Order HOM, HOMT, HOMGFI and HOMAFI Circuit Breakers from page 15
Mains
Rating
(A)
Spaces
aMax.
Number
Single Pole
Circuits
Max.
Number of
Tandem Circuit
Breakers
Load Center
Box, Interior and Cover
Main Wire Size
AWG/kcmil
Equipment Ground Bar Kit
(Order Separately) Box No.
See
page 20
Catalog Number Price
(DE3C) Al Cu Catalog Number Price
(DE3A)
R
A
I
N
P
R
O
O
F
Factory-installed Fixed Main Lugs
70 2 4 2 HOM24L70RB b$74.00 #12–3 #14–4 PK4GTA $7.20 1R
100 6 12 6 HOM612L100RB 86.00 #8–1 PK7GTA 7.80 2R
125 4 8 4 HOM48L125GRB 91.00 #12–2/0 #14–2/0 PK7GTA Factory-included 15R
Convertible Mains—Factory-installed Main Lugsc
QOM1 Main Frame Size—Convertible to 22,000 AIR Main Circuit Breaker (See Below)
125
8168HOM816L125RB 165.00
#6–2/0
PK15GTA 11.40 3R
12 12 0 HOM12L125RB 156.00 PK15GTA 11.40 3R
12 24 12 HOM1224L125RB 185.00 PK15GTA 11.40 3R
20 20 0 HOM20L125RB 255.00 PK15GTA 11.40 4R
Convertible Mains—Factory-installed Main Lugs c
QOM2 Main Frame Size—Convertible to 22,000 AIR Main Circuit Breaker (See Below)
200
12 12 0 HOM12L200RB 282.00
#6–250
PK23GTA 14.20 5R
20 40 20 HOM2040L200RB 373.00 PK23GTA 14.20 6R
30 30 0 HOM30L200RB 391.00 PK23GTA 14.20 7R
40 40 0 HOM40L200RB 607.00 PK23GTA 14.20 14R
Main Circuit Breaker— 22,000 RMS Sym. Amperes Short Circuit Current Rating d
Convertible Mains—Factory-installed Main Circuit Breakerc
QOM1 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See Below)
R
A
I
N
P
R
O
O
F
100
8168HOM816M100RB 286.00
#4–2/0
PK15GTA 11.40 3R
12 12 0 HOM12M100RB 277.00 PK15GTA 11.40 3R
20 20 0 HOM20M100RB 354.00 PK15GTA 11.40 4R
125 24 24 0 HOM24M125RB 572.00 #4–2/0 PK15GTA 11.40 6R
Convertible Mains—Factory-installed Main Circuit Breaker c
QOM2 Main Frame Size—Convertible to Main Lugs or Lower Amperage Main Circuit Breaker (See Below)
150 30 30 0 HOM30M150RB 685.00 #4–250 PK23GTA 14.20 7R
200
20 40 20 HOM2040M200RB 581.00
#4–250
PK23GTA 14.20 6R
30 30 0 HOM30M200RB 669.00 PK23GTA 14.20 7R
30 40 10 HOM3040M200RB 768.00 PK23GTA 14.20 7R
40 40 0 HOM40M200RB 851.00 PK23GTA 14.20 14R
225 16 24 8 HOM1624M225RB 788.00 #4–250 PK15GTA 11.40 7R
42 42 0 HOM42M225RB 882.00 PK23GTA 14.20 14R
Factory-installed Main Circuit Breaker with Feed-thru Lugsc
150 8 16 8 HOM816M150FTRB 523.00 #4–250 PK15GTAL 23.30 6R
200 e8168HOM816M200FTRB 523.00 #4–250 PK15GTAL 23.30 6R
Universal Main with Feed-thru Lugs—No Factory-installed Main Circuit Breaker c
QOM2 Main Frame Size—Field-install 22,000 AIR Main Circuit Breaker (See Kits Below)
200 8 16 8 HOM816U200FTRB 297.00 #4–250 PK15GTAL 23.30 6R
fDo not exceed the load center mains rating.
gWire Range listed for QOL lug kits is the wire range of that lug. To find out maximum wire size
permitted in a particular load center per UL, see pages 17, 18 under main wire size.
hIf main circuit breaker knockout has been removed from the load center’s trim, order
appropriate filler plate from page 14.
Main Lug Kits
Field-installable Main Lugs (Convertible Load Centers Only)
Main Lug f
Ampere Rating
Use On
Convertible Load Center
With Mains Rating
Catalog
Number
Price
(DE3A)
Lug Wire Size g
AWG/kcmil
Al or Cu
125 100–125 QOL125h$29.40 #6–2/0
225 150–225 QOL225h69.00 #6–300
QOL125 QOL225
For additional information, reference Catalog #1100CT9901.
DE3A DE3C Discount
Schedule
Main Circuit Breaker Kits
iDo not exceed the load center mains rating.
j22,000 AIR main circuit breaker UL Listed for use ahead of HOM and HOMT 10,000 AIR
branch circuit breakers to permit their application on systems with up to 22,000 amperes
available fault current.
kWire range listed for QOM circuit breaker kits is the wire range of that circuit breaker. To find
out maximum wire size permitted in a particular load center per UL, see pages 17,18 under
Main Wire Size.
lAdd suffix 1021 for 120, 208, 240 Vac shunt trip. Add $126.00.
Field-installable Main Circuit Breaker (Convertible Load Centers Only)
Main
Circuit Breaker
Rating (A)
i
Use With
Convertible Load
Center
Mains Rating
22,000 AIR jLug Wire Size k
AWG/kcmil
Al or Cu
Main Circuit
Breaker
Price
(DE3A)
QOM1 Frame Size
50 100–125 QOM50VH $93.00
#12–2/0
60 100–125 QOM60VH 93.00
70 100–125 QOM70VH 93.00
80 100–125 QOM80VH 134.00
90 100–125 QOM90VH 134.00
100 100–125 QOM100VH 134.00
110 125 QOM110VH 312.00
125 125 QOM125VH 312.00
QOM2 Frame Size l
100 150–225 QOM2100VH 312.00
#4–300
125 150–225 QOM2125VH 312.00
150 150–225 QOM2150VH 312.00
175 200–225 QOM2175VH 312.00
200 200–225 QOM2200VH 312.00
225 225 QOM2225VH 312.00
LOAD CENTERS
19
QO® and HOMELINE® Load Centers
Indoor—Dimensions, Knockouts
Class 1130, 1170
© 2004 Schneider Electric
All Rights Reserved
6/7/04
www.SquareD.com
For the most up-to-date information
Box 1
A,B,C
A
A
A,B,C
A
A,B,C,D
A,B,C
A
,B,C
A
Box 2
A
Box 3
A,B
B,C,D,E
B,C,D,E
A
A,B
A
Box 4
B,C,D,E
B,C,D,E
B,C,D,E
B,C,D,E
Box 5
A
B,C,D,E C,D,E,F,G A,B
B,C,D,E
A,B,C,D
A,B
A
C,D,E,F
A,B
A
C,D,E,F
Box 6
B,C,D,E
A,B,C,D
B,C,D,E A
C,D,E,F,G A,B
B,C,D,E A
C,D,E,F,G A,B
A,B
A
C,D,E,F
Box 7
B,C,D,E
A,B,C,D
B,C,D,E A
C,D,E,F,G A,B
Box 8
A,B,C,D
B,C,D,E
C,D,E,F
B,C,D,E
D,E,F,G
B,C,D,E A
C,D,E,F,G A,B
A,B
B,C
A
D,E,F,G
C,D,E,F
A,B,C,D
C,D,E,F
D,E,F,G
Box 9
B,C,D,E A
C,D,E,F,G A,B
D,E,F,G
D,E,F,G
C,D,E,F
A,B,C,D
C,D,E,F
B,C,D,E
D,E,F,G
A,B
B,C
A
Box 10
B,C,D,E A
C,D,E,F,G A,B
D,E,F,G
D,E,F,G
C,D,E,F
A,B,C,D
C,D,E,F
B,C,D,E
D,E,F,G
Box 11
A,B
B,C
A
B,C,D,E A
C,D,E,F,G A,B
C,D,E,F
D,E,F,G
C,D,E,F
B,C,D,E
A,B,C,D
B,C,D,E
D,E,F,G
Box 12
A,B
B,C
A
Box 13
A,B,C,D
C,D,E,F C,D,E,F
Box 14
A,B
A
B,C,D,E
B,C,D,E
A,B,C,D
A,B,C
AA,B
D,E,F,G
A,B
C,D,E,F
D,E,F,G,H,I
D,E,F,G,H
Box 15, 16, 17
Box 18
A,B,C,D
C,D,E,F
Box 19
D,E,F,G
Box 20
C,D,E,F
D,E,F,G
E,F,G,H
B,C,D,E
B,C,D,E
A
A,B
A
Box 21
B,C,D,E
B,C,D,E
B,C,D,E
B,C,D,E
Box 22
A,B
C,D,E,F
B,C,D,E
D,E,F,G
A,B
B,C
A
D,E,F,G
C,D,E,F
A,B,C,D
C,D,E,F
D,E,F,G
Box 23
A,B,C
AA,B
D,E,F,G
Knockout Information and Enclosure Dimensions
Indoor
Knockouts
Symbol ABCDEFGH I
Conduit
Size 123411
1411222
1233
12
Dimensions
Box
No.
WHD
IN mm IN mm IN mm
13.81 97 6.72 171 3.00 76
24.81 122 9.30 236 3.19 81
34.81 122 9.30 236 3.19 81
48.88 226 12.57 319 3.80 97
514.25 362 14.92 379 3.75 95
614.25 362 17.92 455 3.75 95
714.25 362 20.92 531 3.75 95
814.25 362 26.04 661 3.75 95
914.25 362 29.86 758 3.75 95
10 14.25 362 33.78 858 3.75 95
11 14.25 362 37.98 965 3.75 95
12 14.25 362 39.37 1000 3.75 95
13 5.88 149 13.12 333 3.38 86
14 14.25 362 20.92 531 3.75 95
15 20.00 508 50.00 1270 5.75 146
16 20.00 508 68.00 1727 5.75 146
17 20.00 508 53.00 1346 5.75 146
18 5.88 149 16.12 409 3.38 86
19 7.56 192 23.12 587 4.25 108
20 9.62 244 26.12 663 4.75 121
21 8.88 226 14.80 376 3.80 97
22 8.55 217 23.92 608 3.95 100
23 14.25 362 29.86 758 3.75 95
Dimensions
Box
No.
WHD
IN mm IN mm IN mm
LOAD CENTERS
www.SquareD.com
For the most up-to-date information
20
QO® and HOMELINE® Load Centers
Rainproof—Dimensions, Knockouts, Bolt-On Hubs
Class 1130, 1170
© 2004 Schneider Electric
All Rights Reserved
6/7/04
aHOME250SPA top endwall has no hub opening.
Enclosure Dimensions
Dimensions
Box No. WHD
IN mm IN mm IN mm
1NM 6.52 166 8.79 223 3.90 99
1Ra4.88 124 9.38 238 4.00 102
2R 8.88 226 12.65 321 4.27 108
3R 14.75 375 18.92 481 4.52 115
4R 14.75 375 22.06 560 4.52 115
5R 14.75 375 26.04 661 4.52 115
6R 14.75 375 29.86 758 4.52 115
7R 14.75 375 33.78 858 4.52 115
8R 14.75 375 37.98 965 4.52 115
9R 4.56 116 6.50 165 3.88 99
10R 6.92 176 13.18 335 4.12 105
11R 7.56 192 23.24 590 4.75 121
12R 9.62 244 26.24 666 5.50 140
13R 6.92 176 16.18 411 4.12 105
14R 14.75 375 39.37 1000 4.52 115
15R 8.88 226 14.80 376 4.27 108
16R 8.55 217 24.75 629 4.16 106
Knockout Information
Knockouts
Symbol ABCDEFGH
Conduit
Size 123411
1411222
123
Bolt-On Hubs
Square D equipment with “R’ or “RB’ suffix, designated rainproof NEMA 3R rainproof construction, utilizes bolt-on hubs listed below. “RB’ devices will
accept 34" through 2" bolt-on hubs without the use of reducers. Off-center conduit thread openings and elongated mounting holes provide quick and
easy adjustment to eliminate costly conduit offsets and bends. Catalog suffix “R’ devices require 3" through 4" field cut opening. Hubs are suitable for
use with conduit having ANSI standard taper pipe thread.
Note: Closing cap (catalog number BCAP) is provided factory-installed on each device having “RB’ suffix. Price if
ordered separately; $2.50
Bolt-On Hubs UL Listed For “RB’ Devices
Conduit Size 34"1"1
14"1
12"2"2
12"
Hub Cat. No. B075 B100 B125 B150 B200 B250
Price $22.20 $22.20 $22.20 $22.20 $40.90 $68.00
Bolt-On Hubs UL Listed For Mounting In Field Cut Opening
Conduit Size 3" 312"4"
Designed for mounting in field cut opening.
Includes gasket and four mounting bolts
and nuts.
Hub Cat. No. B300 B350 B400
Price $124.00 $200.00 $245.00
“RB’ Hub
DE1A Discount
Schedule
Box 1NM
A,B,C
A,B,C,D
A
Box 1R
A,B
2
1
2" Hub Maximum
B,C,D,E
B,C,D,E
A
Box 2R
A,B
2
1
2" Hub Maximum
B,C,D,E
Box 3R, 4R
AA,B C,D,E,F,G
C,D,E,F
C,D,E,F,G
2
1
2" Hub Maximum
C,D,E,F A,B,C
Box 5R
AA,B C,D,E,F,G
C,D,E,F
C,D,E,F,G
2
1
2" Hub Maximum
C,D,E,F A,B,C
Box 6R, 7R, 8R
AA,B C,D,E,F,G
C,D,E,F
C,D,E,F,G
2
1
2" Hub Maximum
C,D,E,F A,B,C
Box 9R
A,B,C
A,B,C,D
C,D,E,F
Box 10R, 13R
B,C,D,E
B,C,D,E
2
1
2" Hub Maximum
D,E,F,G
Box 11R
2
1
2" Hub Maximum
D,E,F,G
Box 12R
2
1
2" Hub Maximum
E,F,G,H E,F
Box 14R
2
1
2" Hub Maximum
AA,B C,D,E,F,G
C,D,E,F
C,D,E,F,G
C,D,E,F A,B,C
B,C,D,E
B,C,D,E
A
Box 15R
A,B
2
1
2" Hub Maximum
B,C,D,E
Box 16R
A,B
2
1
2" Hub Maximum
C,D,E,F
LOAD CENTERS
21
QO® Load Centers
Wiring Diagrams—Single Phase
Class 1130
© 2004 Schneider Electric
All Rights Reserved
6/7/04
www.SquareD.com
For the most up-to-date information
QO2L30S
QO2L40RB
S
N
QO2L30TTSq
S
N
G/B
QO112L125G
QO112L125GC
QO112L125GRB
QO112L200G
QO112L200GRB
S
N
S
N
S
N
S
N
QO11224L125G
QO11224L125GC
QO11224L125GRB
QO11224L125GWGC
QO24L60NRNMq
QO24L70F/S
QO24L70RB
QO24L70TSq
S
N
QO24L50TTSq
S
N
G
B
QO35FM30TTFq
QO35FM30TTSq
QO612L100DFCU/SCU
QO612L100DF/S
QO612L100DTF/Sq
QO612L100F/S
QO612L100RB
QO612L100RBCU
QO612L100TF/Sq
QO612L100TRBq
S/N
QO148L125GF/S
QO148L125GRB
S/N
QO48M30DSGP
QO48M60DSGP
Generator Panel
S/N
QO816L100DF/S
QO816L100DFCU/SCU
QO816L100DTF/Sq
QO816L100F/S
QO816L100RB
QO816L100RBCU
QO816L100TF/Sq
S/N
QO116L125G
S
N
S
N
QO11624L125G
QO11624L125GRB
S
N
S
N
S/N
QON12LS400
S
N
S
N
QO120L125G
QO120L125GC
S
N
S
N
QO12030L150G
S
N
S
N
QO12024L125G
QO12024L125GWGC
S
N
S
N
QO124L125G
QO124L125GRB
QO124L150G
S
N
S
N
QO130L150G
QO130L150GRB
QO130L200G
QO130L200GRB
S
N
S
N
QO13040L200G
QO13040L200GC
QO13040L200GRB
QO13040L200WG
S
N
S
N
QO142L225G
QO142L225GRB
QON30LS400
S/N S/N
QON42LS400
Main S
N
QO1612M125FTRB
S
F
S
NMain S
N
QO1816M150FTRB
QO1816M200FTRB
Main S
N
S
N
QO112M100
QO112M100C
QO112M100RB
Main S
N
S
N
QO116M100
QO116M100C
QO116M100RB
Main S
N
S
N
QO120M100
QO120M100C
QO120M100RB
Main S
N
S
N
QO11220M100C
1 Phase 3 Wire Main Lugs
1 Phase 3 Wire Main Breaker
S/N G/B
Main Main
Line
q Includes Factory Installed Ground Bar
S
N
QO12436L200TFT
S
N
G
B
S
N
S
N
QO132L125G
S
N
S
N
QO140L200G
QO140L200GRB
LOAD CENTERS
www.SquareD.com
For the most up-to-date information
22
QO® Load Centers
Wiring Diagrams—Single & Three Phase
Class 1130
© 2004 Schneider Electric
All Rights Reserved
6/7/04
QO403L60NF/S
QO403L60NRB
S
N
QO312L125G
QO312L125GRB
S
N
S
N
QO324L125G
S
N
S
N
QO320L125G
QO320L125GRB
S
N
S
N
QO342MQ150
QO342MQ200
QO342MQ200RB
QO342MQ225
QO342MQ225RB
S
N
S
N
Main
QO342L225G
QO342L225GRB
S
N
S
N
QO327M100
QO327M100RB
S
N
S
N
QO318L200G
QO318L200GRB
S
N
S
N
QO330L200G
QO330L200GRB
S
N
S
N
M
a
i
n
QO330MQ125
QO330MQ125RB
QO330MQ150
QO330MQ150RB
QO330MQ200
QO330MQ200RB
S
N
S
N
Main
3 Phase 4 Wire Main Lugs
3 Phase 4 Wire Main Circuit Breaker
QON42MS300
QON42MS400
Main
S/N
QO142M200
QO142M225
Main S
N
S
N
1 Phase 3 Wire Main Breaker (Continued)
Main S
N
S
N
QO12030M150
QO12030M150C
QO12030M150RB
Main S
N
S
N
QO12040M200
QO12040M200C
QO12040M200RB
QO12040M200TCq
Main S
N
S
N
QO124M100
QO124M125
QO124M125RB
QO124M150
QO124M200
Main S
N
S
N
QO130M150
QO130M150C
QO130M150RB
QO130M200
QO130M200C
QO130M200RB
Main S
N
S
N
QO132M100
QO132M125
QO132M150
Main S
N
S
N
QO140M200
QO140M200C
QO140M200RB
QO140M225
Main S
N
S
N
QO13040M200
QO13040M200C
q Includes Factory Installed Ground Bar
LOAD CENTERS
23
HOMELINE® Load Centers
Wiring Diagrams
Class 1170
© 2004 Schneider Electric
All Rights Reserved
6/7/04
www.SquareD.com
For the most up-to-date information
1 Phase 3 Wire Main Lugs
1 Phase 3 Wire Main Breaker
Universal Mains
HOM24L70F/S
HOM24L70RB
S
N
HOM612L100F/S
HOM612L100RB
S/N
HOM816L125C
HOM816L125RB
HOM816L125TCqHOM12L125C
HOM12L125RB
HOM12L200RB
HOM1224L125TCq
HOM1224L125RB
HOM1624L125C
S
N
S
N
S
N
S
N
S
N
S
N
G
B
G
B
G
B
S
N
S
N
HOM1632L200TCq
S
N
S
N
G
B
HOM2040L200TCq
S
N
S
N
S
N
HOM2024L125TCq
S
N
S
N
HOM20L125C
HOM20L125RB
S
N
S
N
HOM24L125TCq
S
N
G
BG
B
S
N
HOM30L150C
HOM30L200C
HOM30L200RB
HOM30L200TCq
S
N
S
N
HOM3040L200TCq
S
N
G
B
S
N
HOM40L200C
HOM40L200RB
S
N
S
N
HOM42L225C
S
N
S
N
HOM816M100C
HOM816M100RB
HOM816M100TCq
S
N
Main S
N
HOM816M150FTRB
HOM816M200FTRB
S
N
Main S
N
HOM12M100C
HOM12M100RB
S
N
Main
G
B
S
N
HOM1224M125C
S
N
Main
S
N
HOM1224M100TCq
HOM1224M125TCq
HOM1224M200TCq
S
N
Main
G
B
S
N
HOM1632M150TCq
HOM1632M200TCq
S
N
Main
S
N
HOM20M100C
HOM20M100RB
S
N
Main S
N
HOM2040M200C
HOM2040M200RB
HOM2040M200TCq
S
N
Main
G
B
S
N
HOM2030M150TCq
S
N
Main
S
N
HOM24M100C
HOM24M125C
HOM24M125RB
S
N
Main Main
Main
S
N
HOM30M100C
HOM30M125C
HOM30M150C
HOM30M150RB
HOM30M200C
HOM30M200RB
S
N
S
N
HOM3040M200RB
HOM3040M200TCq
S
NMain
S
N
HOM40M200C
HOM40M200RB
S
N
Main
S
N
HOM42M200C
HOM42M225C
S
N
HOM1632U200TCq
S
N
G
B
S
N
HOM2040U200TCq
S
N
G
B
S
N
S
N
HOM3040U200TCq
S
N
G
B
S
N
HOM816U200FTRB
S
N
HOM48L125GC
HOM48L125RB
S/N
q Includes Factory Installed Ground Bar
HOM1632L200TCFTq
S
N
G
B
S
N
S
N
HOM1624M225RB
S
N
Main
Combination
SERVICE ENTRANCE DEVICE (CSED)
Flexibility...
Meter-Main CSEDs
Meter main devices are used in residential applications where local codes
require service disconnects to be located outside the dwelling. They include
the utility meter socket and factory installed and/or provisions for field
installation of service disconnect(s) to feed downstream devices. Meter
mains are surface mount and typically used with interior mounted sub-feed
load centers.
All-In-One CSEDs
These devices come with a 30/40 circuit 200 A main circuit breaker load
center and an additional 200 A maximum service disconnect for subfeed
applications. 300 A and 400 A versions are available.
Meter Mains
Square D meter mains include a basic meter socket and single main
service disconnect. Dual main devices are available to feed a second load,
such as a water pump, with a separate service disconnect. Four or six main
disconnect units provide flexibility for feeding additional loads, such as air
conditioning, spa, swimming pool, or garage.
Ring or ringless styles meet local utility requirements
Fifth jaw and horn bypasses available
24
LOAD CENTERS
25
Combination Service Entrance Devices
Rainproof—Single Phase, Meter-Mains
Class 4119/4120
© 2004 Schneider Electric
All Rights Reserved
6/7/04
www.SquareD.com
For the most up-to-date information
DE3A Discount
Schedule
aService disconnect supplied factory-installed.
bFor use only on 120/240 Vac, 1-Phase, 3-Wire system. (4-jaw meter socket.)
cKnockout provided in cover for use with barrel lock kit, order catalog number SCBRLLOCK
(see Accessories page 27).
d125 A HOMELINE® 2-pole circuit breaker can be installed in top position only. All other
positions are limited to 100 A max.
eUL short circuit current rating is equal to the lowest interrupting rating of any circuit breaker
installed.
fSuitable for OH service with addition of tunnel kit (SCTK20). Order separately.
gSupplied with load side feed thru lugs, for #6 AWG–250 kcmil (Al/Cu) conductors.
hConvertible to semiflush with SC200F flange kit (order separately).
iDevice supplied with barrel lock provisions factory-installed.
jSupplied with horn bypass and 5th jaw factory-installed.
kNot stocked in PDS, contact Lexington for delivery.
l5th jaw factory-installed.
mQO panel is rated 200 A maximum.
nCircuit breaker prefix QBL at 10 kAIR may be used. For complete circuit breaker catalog
number, see page 29.
Meter-Mains
Meets Federal Spec. W-P-115c as Type 1, Class 2, UL Listed, suitable only for use as service equipment, 120/240 Vac, 1-Phase, 3-Wire, NEMA 3R enclosure
Ampere
Rating
By-
pass
Type
Service
(Type of Feed)
Short Circuit
Current Rating
Catalog
Number
List
Price
(DE3A)
Service Disconnect(s)
Load Center and Branch
Circuit Breakers
(Order separately
page 27) Hub
Type
(Order
separately
from
page 27)
Line
Side
Main
Lugs
AWG/
kcmil
(Al/Cu)
Service
Ground
Lug
AWG/
kcmil
(Al/Cu)
Weight
Each
(Lbs)
and
Pallet
Qty.
Max. Quantity
Ampere
Rating (Max.)
Spaces
1-pole
2-pole
Circuits
(Max.)
Type (Order
Separately from
page 27
except as noted)
Am-
pere
Rating
(Max.)
Circuits
TandemsUL UL &
EUSERC
RING TYPE
QO®
Surface Mount only
125 None OH/UG . . . 10k C125RB 245. 1QOM1-VH 125 ..... ..... ..... ..... B #4–1/0 #8–1/0 15, 54
200 None
OH/UG . . . 22k CM200S 681. 1QOM2-VH 200 ..... ..... ..... ..... A #4–250 (2) #8–2/0 26, 24
OH/UG . . . 22k C2M200S 722. 1
1
QOM2-VH
QO-VH
200
50
.....
.....
.....
.....
.....
.....
....
.... A#4–250 (2) #8–2/0 27, 20
. . .
OH/UG . . . 10k C4L200S 762. 2QO 100 ..... ..... ..... ..... A #4–250 (2) #8–2/0 27, 28
Surface Mount, convertible to Semiflush with FK400 flange kit (order separately)
400 None UG UG 25k CU12L400CN b2540.
1QDL22200a200 ..... ..... ..... .....
A-L (2) Studs #4–250 98, 41QDL, QGL, QJLn200 ..... ..... ..... .....
4QOHe200m..... ..... ..... .....
400
Class
320
Manual
Bypass
UG UG 25k CU12L400CB b2657. A-L (2) Studs #4–250 98, 4
1QDL22200a200 ..... ..... ..... .....
1QDL, QGL, QJLn200 ..... ..... ..... .....
4QOHe200m..... ..... ..... .....
400 None UG UG 25k CU816D400CNgb 2650. 1QDL22200a200 8 16 8 200 A-L (2) Studs #4–250 98, 4
1QDL, QGL, QJLn200 ..... ..... ..... .....
400
Class
320
Manual
Bypass
UG UG 25k CU816D400CBgb 2767.
1QDL22200a200 8 16 8 200
A-L (2) Studs #4–250 98, 4
1QDL, QGL, QJLn200 ..... ..... ..... .....
HOMELINE
Surface Mount only
125 None OH/UG OH/UG 10k SC8L125S 564. 4HOM 125d..... ..... ..... ..... A #6–2/0 #12–4 31, 24
200 None OH/UG OH/UG 10k SC12L200S 946. 6HOM 200 ..... ..... ..... ..... A–L #4–250 #12–2/0 40, 10
Semiflush Mount only
125 None OH/UG OH/UG 10k SC8L125F 564. 4HOM 110 ..... ..... ..... ..... A or B300 #6–2/0 #12–2/0 37, 20
200 None OHf/UG OHf/UG 10k SC12L200F 946. 6HOM 200 ..... ..... ..... ..... A–L #4–250 #12–2/0 47, 10
None OHf/UG OHf/UG 22k SC816F200F g791. 1QOM2200VHa200 8 16 8 200 A–L #4–250 #12–2/0 51, 10
Surface Mount—Supplied with Feed Thru Lugs and provisions for Branch Circuit Breakers
150 None OH/UG OH/UG
22k SC816F150S g791. 1QOM2150VHa150 8 16 8 150 A–L #4–250 #12–2/0 40, 10
10k SC816D150Cgh 833. 1
1
HOM2150a
HOM
150
50
8
.....
16
.....
8
.....
100
..... A or A–L #6–300 #12–1/0 48, 18
200 None OH/UG OH/UG
22k SC816F200S g791. 1QOM2200VHa200 8 16 8 200 A–L #4–250 #12–2/0 40, 10
10k SC816D200Cgh 833. 1
1
HOM2200a
HOM
200
50
8
.....
16
.....
8
.....
100
..... A or A–L #6–300 #12–1/0 48, 18
RINGLESS
QO
Surface Mount Only
200
None
OH/UG ..... 22k
RC200S 681. 1QOM2-VH 200
..... ..... ..... .....
A#6–350 (2)#8–2/0 26, 24
None RC2M200S 722. 1QOM2-VH 200 A #6–350 (2)#8–2/0 27, 20
Horn RC2M200SH 757. 1QO-VH 50 A #6–350 (2)#8–2/0 27, 20
None QC12L200Ci1041. 6QO-VH 200 A #6–350 #12–2/0 40, 21
Horn QC12L200CHijk 1255. 6QO-VH 200 A #6–350 #12–2/0 40, 21
400
Class
320
Lever
UG ..... 25k QU12L400SL l2540.
1QDL22200a200 ..... ..... ..... .....
A-L (2) Studs #4–250 98, 41QDL, QGL, QJLn200 ..... ..... ..... .....
4QOHe200m..... ..... ..... .....
Surface Mount Only, Supplied with Feed Thru Lugs and provisions for Branch Circuit Breakers
100 Horn OH/UG ..... 22k QC816F100CHgijk 904. 1QOM2100VHa100 8 16 8 100
A#6–350 #12–2/0 40, 21
125 None OH/UG ..... 22k QC816F125Cgi 869. 1QOM2125VHa125 8 16 8 100
Horn OH/UG ..... 22k QC816F125CHgij 904. 1QOM2125VHa125 8 16 8 100
150 None OH/UG ..... 22k QC816F150Cgi 869. 1QOM2150VHa150 8 16 8 150
Horn OH/UG ..... 22k QC816F150CHgij 904. 1QOM2150VHa150 8 16 8 150
200 None OH/UG ..... 22k QC816F200Cgi 904. 1QOM2200VHa200 8 16 8 200
Horn OH/UG ..... 22k QC816F200CHgij 904. 1QOM2200VHa200 8 16 8 200
400
Class
320
Lever
UG ..... 25k QU816D400SLg2710.
1QDL22200a200 8 16 8 200
A-L (2) Studs #4–250 98, 41QDL, QGL, QJLn200 8 16 8 200
Surface Mount, convertible to Semiflush with FK400 flange kit (order separately)
400 Class
320
Lever
UG UG 25k QU12L400CL lc 2540.
1QDL22200a200 ..... ..... ..... .....
A-L (2) Studs #4–250 98, 41QDL, QGL, QJLn200 ..... ..... ..... .....
4QOHe200m..... ..... ..... .....
400 UG UG 25k QU816D400CL lcg 2710. 1QDL22200a200 8 16 8 200 A-L (2) Studs #4–250 98, 4
1QDL, QGL, QJLn200 ..... ..... ..... .....
HOMELINE
Surface Mount Only
125 None OH/UG ..... 10k RC8L125S 564. 4HOM 125d..... ..... ..... ..... A #6–2/0 #12–4 27, 32
200 None OH/UG ..... 10k RC12L200Ci946. 6HOM 200 ..... ..... ..... ..... A #6–350 #12–2/0 40, 21
200 Horn OH/UG ..... 10k RC12L200CHijk 946. 6HOM 200 ..... ..... ..... ..... A #6–350 #12–2/0 40, 21
Surface Mount Only, Supplied with Feed Thru Lugs and provisions for Branch Circuit Breakers
100 Horn OH/UG ..... 22k RC816F100CHgij 818. 1QOM2100VHa100 8 16 8 100
A#6–350 #12–2/0 40, 21
125 Horn OH/UG ..... 22k RC816F125CHgij 818. 1QOM2125VHa125 8 16 8 100
150 None OH/UG ..... 22k RC816F150Cgi 791. 1QOM2150VHa150 8 16 8 150
Horn OH/UG ..... 22k RC816F150CHgij 818. 1QOM2150VHa150 8 16 8 150
200 None OH/UG ..... 22k RC816F200Cgi 818. 1QOM2200VHa200 8 16 8 200
Horn OH/UG ..... 22k RC816F200CHgij 818. 1QOM2200VHa200 8 16 8 200
200 Horn OH/UG ..... 10k RC816D200CHcghj 861. 1HOM2200 a200 8 16 8 100 A or B300 #6–300 #6–1/0 48, 18
1HOM 50 ... ... ... ...
LOAD CENTERS
www.SquareD.com
For the most up-to-date information
26
Combination Service Entrance Devices
Rainproof—Single Phase, All-In-Ones
Class 4120
© 2004 Schneider Electric
All Rights Reserved
6/7/04
DE3A Discount
Schedule
All-In-Ones
Ring or ringless type meter socket designs available
UL Listed, suitable only for use as service equipment
Meets EUSERC standards
Service disconnect(s) are supplied factory-installed,
except where noted
Semiflush-REVERSE design available, supplied with load center
(indoor access)
Supplied with 100% branch neutrals, all unused terminals may be
used for equipment grounding wires.
Meets Federal Specification W-P-115c as Type 1, Class 2
a125 A HOMELINE® 2-pole circuit breaker can be installed in top position only. All other
positions are limited to 100 A max.
bConvertible to semiflush with SC200F flange kit (order separately).
cSuitable for OH service with addition of tunnel kit (SCTK20). Order separately.
dSuitable for OH service with addition of tunnel kit (SCTK30). Order separately.
eUL short circuit current rating is equal to the lowest interrupting rating of any circuit breaker
installed.
fKnockout provided in cover for use with barrel lock kit, order catalog number SCBRLLOCK
(see Accessories page 27).
gFor use only on 120/240 Vac, 1-Phase, 3-Wire system (4-jaw meter socket).
hDevice not EUSERC approved.
iDevice supplied with barrel lock provisions factory-installed.
jSupplied with horn bypass and 5th jaw factory-installed.
k5th jaw factory-installed.
lAdditional service disconnect for field-installation, order prefix QBL at 10 kA, QDL at 25 kA,
QGL at 65 kA or QJL at 100 kA. Order separately. For complete circuit breaker catalog
number, see page 29.
Ampere
Rating
By-
pass
Type
Service
(Type
of Feed)
UL &
EUSERC
Short Circuit
Current Rating
Catalog
Number
List
Price
(DE3A)
Service Disconnect(s)
Load Center & Branch
Circuit Breakers
(Order separately
page 27)
Hub Type (Order
Separately page 27)
Line
Side
Main
Lugs
AWG/
kcmil
(Al/Cu)
Service
Ground
Lug
AWG/
kcmil
(Al/Cu)
Weight
Each
(Lbs)
and
Pallet
Qty.
Max. Quantity
Ampere
Rating (Max.)
Spaces
1-pole
Circuits
Tandems
2-pole
Circuits
(Max.)
Type
(Factory
Installed)
Ampere
Rating
(Max.)
RING TYPE
HOMELINE
Surface Mount only
100 None OH/UG 10k SC1624M100S $496. 1HOM2100 100 16 24 8 100 A#6–2/0 #12–4 32, 24
125 None OH/UG 10k SC1624M125S 1012. 1HOM2125 125 16 24 8 125a
200 None OH/UG 22k SC2040M200S 1114. 1QOM2200VH 200 20 40 20 200 A-L #4–250 #12–2/0 45, 10
200 None OH/UG 10k SC2040M200Cb1199. 1HOM2200 200 20 40 20 100 A or
A-L #6–300 #12–1/0 47, 18
Semiflush Mount only
100 None OH/UG 10k SC1624M100F $496. 1HOM2100 100 16 24 8 100 A or
B300 #6–2/0 #12–2/0 44, 20
125 None OH/UG 10k SC1624M125F 1012. 1HOM2125 125 16 24 8 110
OHc/UG 22k SC2040M125F 1114. 1QOM2125VH 125 20 40 20 110
A-L #4–250 #12–2/0
51, 10
200 None OHc/UG 22k SC2040M200F 1114. 1QOM2200VH 200 20 40 20 200
OHd/UG SC3040M200F 1376. 1QOM2200VH 200 30 40 10 200 56, 10
225 None 22k SC3040M225F 1520. 1QOM2225VH 225 30 40 10 200
Surface Mount only
100 None OHh10k SO1020M100S $295. 1HOM2100 100 10 20 10 80 A #6–1 #14–4 20, 42
200 None OHh22k SO2040M200S 774. 1QOM2200VH 200 20 40 20 200 A #6–350 #8–2/0 43, 21
200 None OH/UG 22k SC3040M200S 1340. 1QOM2200VH 200 30 40 10 200 A-L #4–250 #12–2/0 50, 10
SC40M200S 1621. 1QOM2200VH 200 40 40 0 200 #4–250 #12–2/0 52, 10
REVERSE All-In-One - Semiflush Mount with Service Disconnect (outdoor access) and Load Center (indoor access)
200 None UG 10k SU3040M200R $1482. 1QOM2200VH 200 30 40 10 200 A or
B300 #6–300 #12–1/0 60, 15
225 None UG 10k SU3040M225R 1764. 1QOM2225VH 225
Surface Mount, convertible to Semiflush with FK400 flange kit (order separately)
300
Class 320
Manual
Bypass
UG 25k SU3040D300CBfg 4400.
1QDL22200 200 30 40 10 200
A-L (2) Studs #4–250 100, 4
1QDL, QGL, QJLle 100 ..... ..... ..... .....
400 None UG 25k SU3040D400CNfg 4700. 1QDL22200 200 30 40 10 200 A-L (2) Studs #4–250 100, 4
1QDL, QGL, QJLle 200 ..... ..... ..... .....
400
Class 320
Manual
Bypass
UG 25k SU3040D400CBfg 4778.
1QDL22200 200 30 40 10 200
A-L (2) Studs #4–250 100, 4
1QDL, QGL, QJLle 200 ..... ..... ..... .....
RINGLESS
HOMELINE
Surface Mount Only
100 None OH/UGh10k RC1624M100S 496. 1HOM2100 100 16 24 8 100 A#6–2/0 #12–4 32, 24
125 RC1624M125S 1012. HOM2125 125 125a
125 Horn OH/UGh22k RC2040M125CHij 1067. 1QOM2125VH 125 20 40 20 100
A#6–350 #12–2/0 40, 21
150 Horn OH/UGh22k RC2040M150CHij 1142. 1QOM2150VH 150 20 40 20 150
200 None OH/UGh22k RC2040M200Ci1142. 1QOM2200VH 200 20 40 20 200
Horn OH/UGh22k RC2040M200CHij 1142. 1QOM2200VH 200 20 40 20 200
All-In-One Surface Mount, convertible to Semiflush with FK400 flange kit (order separately)
400
Class
320
Lever
UG 25k RU3040D400CLfk 4662.
1QDL22200 200 30 40 10 200
A-L (2) Studs #4–250 100, 6
1QDL, QGL, QJLle 200 ..... ..... ..... .....
400
K-4
Bolt-On
None
UG 25k RU3040D400CKf4662.
1QDL22200 200 30 40 10 200
1QDL, QGL, QJLle 200 ..... ..... .....
QO
Surface Mount Only
150 Horn OH/UGh22k QC2442M150CHij 1270. 1QOM2150VH 150 24 42 18 150
A#6–350 #12–1/0 40, 21
200 None OH/UGh22k QC2442M200Ci1270. 1QOM2200VH 200 24 42 18 200
Horn OH/UGh22k QC2442M200CHij 1270. 1QOM2200VH 200 24 42 18 200
LOAD CENTERS
27
Combination Service Entrance Devices
Circuit Breakers, Accessories, Hubs
Class 4119/4120
© 2004 Schneider Electric
All Rights Reserved
6/7/04
www.SquareD.com
For the most up-to-date information
Accessories
Description Catalog
Number Price Disc.
Sch.
Touch-Up Paint
(ASA49 Gray) PK49SP $26.00 (DE1)
Ground Bar Kit
Meter Mains and All-In-Ones
QC, RC, and SC (100–225 A) PK15GTA 11.40 (DE3A)
Filler Plate for:
Meter Main Types: QC, CU
All-In-One Types: QC
QOFP 2.40 (DE3A)
Filler Plate for:
Meter Main Types: RC, SC
All-In-One Types: SC, RC, SU
HOMFP 2.10 (DE3A)
Neutral Lug (#6-2/0) for:
Meter Main Types: RC, SC, QC
All-In-One Types: SC, SU, QC, RC
LK100AN 7.20 (DE3A)
dOrder only. Not stocked in PDS. Order Point: Lexington.
Accessories
Description Catalog
Number Price Disc.
Sch.
Generator Kit: Interlocks main service disconnect and
generator circuit breaker (order separately). For use on:
HOMELINE® CSED Devices
RC816F-, RC2040M-, SO2040M-
QO CSED Devices
QC816F-, QC2442M-
RCGK2
QCGK3
$163.00
163.00
(DE3A)
Fifth Jaw Kit for:
Meter Main Types: C, RC, SC, QC
All-In-One Types: SC, SU (100–225 A), QC, RC, SO
5J 12.20 (DE3A)
Bypass (Horn Type) for:
Ringless Type Meter Mains and All-In-Ones (100–200 A) RCHB2 61.00 (DE3A)
Lexan Meter Socket Cover Plate for:
Ring and Ringless Type Meter Mains
Ring and Ringless Type All-In-Ones
29007 6.70 (DE4)
Meter Socket Sealing Rings for Ring Type
Meter Mains and All-In Ones:
Screw Type Aluminum
Snap Type Stainless Steel
29008W
ARP00026 d
13.40
11.70
(DE4)
Tr im Kit for 2" X 6" stud wall, used with:
REVERSE All-In-Ones, SU3040M200R, and
SU3040M225R
SU2X6TRIM 177.00 (DE3A)
Barrel Lock Kit (Barrel Lock not included),
supplied with bracket and mounting screw,
refer to listings for where used.
SCBRLLOCK 35.30 (DE3A)
Semiflush Flange Kit for:
Meter Mains: SC816D150/200C and RC816D200CH
All-In-Ones: SC2040M200C
SC200F 21.20 (DE3A)
Semiflush Flange Kit for:
Ring and Ringless Type Meter Mains and
All-In-Ones 400 A)
FK400 131.00 (DE3A)
Ringless Type Utility Cover for use on:
RU3040D400CL, QU12L400CL, and QU816D400CL.
Includes one piece meter socket and pull box cover
with handles and closing plate.
R400L 177.00 (DE3A)
Lug Kit includes (4) lugs, for use with
#2 AWG–600 kcmil Al/Cu conductors. Lugs are for
standard 2-Hole mounting. Meter Main and All-In-One
units supplied with (2) Studs per phase and neutral will
accept one lug per phase and neutral
CMELK4d91.00 (DE4)
Overhead Feed Trough: For use on 400 A ring and ringless
type meter mains and All-in-Ones. OCK400 378.00 (DE3A)
3" Conduit Adapter Kit: For use on 400 A ring and ringless
type meter mains and All-in-Ones. SU400PVCHA3 8.80 (DE3A)
eSupplied with AAP adapter plate and “A” hub.
Hubs and Closing Plates
Hub
Series
Conduit Size
(inches)
Catalog
Number
List
Price
Disc.
Sch.
Closing Plate for “A” Hub opening ACP $8.90 (DE4)
A
1.00 A100 22.60 (DE4)
1.25 A125 22.60 (DE4)
1.50 A150 22.60 (DE4)
2.00 A200 31.90 (DE4)
2.50 A250 40.40 (DE4)
Adapter plate to allow use of “A” Hubs
on “A-L size hub openings AAP 22.50 (DE4)
Closing Plate for “A-L” Hub opening ACPL 12.20 (DE4)
A-L
2.00 A200L e55.00 (DE4)
2.50 A250L 58.00 (DE4)
3.00 A300L 74.00 (DE4)
3.50 A350L 76.00 (DE4)
4.00 A400L 79.00 (DE4)
Closing Plate for “B” Hub opening BCAP 2.50 (DE1A)
B
0.75 B075 22.20 (DE1A)
1.00 B100 22.20 (DE1A)
1.25 B125 22.20 (DE1A)
1.50 B150 22.20 (DE1A)
2.00 B200 40.90 (DE1A)
2.50 B250 68.00 (DE1A)
B300 3.00 B300 124.00 (DE1A)
DE1 DE1A DE2A DE3A DE3D DE4 Discount
Schedule
aDo not exceed mains rating of device
bReference National Electrical Code Article 230-79.
cFor additional interrupting rating circuit breakers, order circuit breaker prefix QBL at 10 kA, QGL at 65 kA or QJL at 100 kA, see page 29.
Circuit Breakers
For use with Meter Mains and All-In-One devices
Ampere
Rating
a
Type: HOM, 1-pole Type: HOM, 2-pole Type: QO, 1-pole Type: QO, 2-pole Type: QO-VH, 1-pole Type: QO-VH, 2-pole
Catalog
Number
Price
(DE3D)
Catalog
Number
Price
(DE3D)
Catalog
Number
Price
(DE2A)
Catalog
Number
Price
(DE2A)
Catalog
Number
Price
(DE2A)
Catalog
Number
Price
(DE2A)
10 . . . . . . . . . . . . QO110 $20.40 . . . . . . . . . . . . . . . . . .
15 HOM115 $17.50 . . . . . . QO115 19.40 . . . . . . QO115VH $42.30 . . . . . .
20 HOM120 17.50 . . . . . . QO120 19.40 . . . . . . QO120VH 42.30 . . . . . .
25 HOM125 17.50 . . . . . . QO125 19.40 . . . . . . QO125VH 48.50 . . . . . .
30 HOM130 17.50 HOM230 $40.30 QO130 19.40 QO230 $44.70 QO130VH 48.50 QO230VH $97.00
35 . . . . . . HOM235 40.30 QO135 20.40 QO235 46.90 . . . . . . . . . . . .
40 HOM140 17.50 HOM240 40.30 QO140 19.40 QO240 44.70 . . . . . . QO240VH 97.00
45 . . . . . . HOM245 40.30 QO145 20.40 QO245 46.90 . . . . . . . . . . . .
50 HOM150 17.50 HOM250 40.30 QO150 19.40 QO250 44.70 . . . . . . QO250VH 97.00
60 . . . . . . HOM260 40.30 QO160 20.40 QO260 44.70 . . . . . . QO260VH 97.00
70 . . . . . . HOM270 82.00 QO170 46.90 QO270 89.00 . . . . . . QO270VH 149.00
80 . . . . . . HOM280 112.00 . . . . . . QO280 126.00 . . . . . . QO280VH 210.00
90 . . . . . . HOM290 112.00 . . . . . . QO290 126.00 . . . . . . QO290VH 210.00
100 . . . . . . HOM2100 112.00 . . . . . . QO2100 126.00 . . . . . . QO2100VH 210.00
110 . . . . . . HOM2110 258.00 . . . . . . QO2110 285.00 . . . . . . QO2110VH 689.00
125 . . . . . . HOM2125 246.00 . . . . . . QO2125 285.00 . . . . . . QO2125VH 689.00
150 . . . . . . HOM2150BB 285.00 . . . . . . QO2150 327.00 . . . . . . QO2150VH 707.00
175 . . . . . . HOM2175BB 285.00 . . . . . . QO2175 327.00 . . . . . . QO2175VH 707.00
200 . . . . . . HOM2200BB 285.00 . . . . . . QO2200 327.00 . . . . . . QO2200VH 707.00
Ampere
Rating
a
Type: QOM1-VH, 2-pole Type: QOM2-VH, 2-pole Type: QDL, 2-polec
Catalog Number Price (DE3A) Catalog Number Price (DE3A) Catalog Number Price (DE2A)
50 QOM50VHb$93.00 . . . . . . . . . . . .
60 QOM60VH 93.00 . . . . . . . . . . . .
70 QOM70VH 93.00 . . . . . . QDL22070 $762.00
80 QOM80VH 134.00 . . . . . . QDL22080 762.00
90 QOM90VH 134.00 . . . . . . QDL22090 762.00
100 QOM100VH 134.00 QOM2100VH $312.00 QDL22100 762.00
110 QOM110VH 312.00 . . . . . . QDL22110 762.00
125 QOM125VH 312.00 QOM2125VH 312.00 QDL22125 762.00
150 . . . . . . QOM2150VH 312.00 QDL22150 762.00
175 . . . . . . QOM2175VH 312.00 QDL22175 762.00
200 . . . . . . QOM2200VH 312.00 QDL22200 762.00
225 . . . . . . QOM2225VH 312.00 . . . . . .
LOAD CENTERS
www.SquareD.com
For the most up-to-date information
28
Combination Service Entrance Devices
Dimensions
Class 4119, 4120
© 2004 Schneider Electric
All Rights Reserved
6/7/04
4.60
117
12.80
325
7.44
189
13.82
351
“B” Hub
C125RB (Shown)
CQRB100
A,B C,D,E,F
Ring Type:
CM200S
C2M200S (Shown)
C4L200S
Ringless Type:
RC200S
RC2M200S
RC2M200SH
A,B E,F,G,H
D,F,G
18.23
463
10.70
272
19.58
497
“A” Hub
4.60
117
A,B
B,C
A
21/2" Max “A” Hub
13.46
342
4.56
116
SO1020M100S
C,D,E,F
20.79
528
6.44
164
SC816D150Cq (Shown)
SC816D200Cq
SC2040M200Cq
RC816D200CHq
32.23
819
14.81
376
6.95
176
14.50
368
B,C C,D,F
21/2" Max “A” Hub
D,F,G
A,B
C,E,F,G,H
21/2" Max
“A-L” Hub
C,D,E,F B,C
B,C
A
7.
50
1
91
8
.
00
2
03
41.2
5
1
0
4
8
2
8
.2
5
71
8
C
,
D
,F
A
B
,C
CU
12L4
00CN
c
CU
12L4
00CB
c
Q
U12L400C
L
c
QU12L400SL
CU8
1
6
D4
00CB
c
CU8
1
6
D4
00CN
c
Q
U816D400C
L
c
QU816D400SL (Shown)
Bl
a
nk En
d
W
a
l
l
G
,
H
,
I
,J
A
-
L
H
ub
10.87
276
25.12
638
14.77
375
SC8L125S (Shown)
RC8L125S
SC1624M100S
SC1624M125S
RC1624M100S
RC1624M125S
4.80
122
C,D,F
A
A,B
B,C
21/2" Max “A” Hub
21/2" Max
“A” Hub
D,F,G
Surface
2
1
/
2
" Max “A” Hub
10.04
255
35.13
892
14.37
365
RC816F100CH
RC816F125CH
RC816F150C/CH
RC816F200C/CH
RC12L200C/CH
RC2040M125CH
RC2040M150CH
RC2040M200C/CH
QC816F100CH
QC816F125C/CH
QC816F150C/CH (Shown)
QC816F200C/CH
QC12L200C/CH
QC2442M150CH
QC2442M200C/CH
SO2040M200S
4.67
119
C,D,E,F
D,E,F,G
A,B,C
A,B
C,D,E,F
SC8L125F (Shown)
SC1624M100F
SC1624M125F
25.12
638
10.87
276
3.39
86
14.50
368
B,C
A,B
C,D,F
A
AA,B B,C
D,F,G
21/2" Max
“A” Hub or
B300
SU3040M200R (Shown)
SU3040M225R
14.62
371
31.61
803
48.00
1219
B,C B
B
B
D,F,G C,D
C,D,F A,B A
A
7.90
201
4.40
112
3.50
89
27.00
686
C
L
Meter
Socket
C
L
Top
Branch
Circuit
Breaker
“A” Hub or
B300 Hub
3.40
86
C,E,F,G,H
21/2" Max
“A-L” Hub
SC816F200F
SC12L200F
SC2040M125F
SC2040M200F (Shown)
SC3040M200F
SC3040M225F
14.85
377
10.30
262
35.40
899
39.60
1006
A
A,B
C,D,E,F
35.40
899
C,D,E,F
B,C
A
B,C B
39.60
1006
21/2" Max “A” Hub
29.50
749
SC12L200S
SC816F150S
SC816F200S
SC40M200S
SC2040M200S (Shown)
SC3040M200S
5.80
147
21.50
546
C,E,F,G,H
21/2" Max
“A-L” Hub
A
B,C
B
C,D,E,F
11.10
282
32.30
820
37.30
947
SC40M200S
SC3040M200S
G
,
H
,
I
,J
A
-
L
H
ub
8
.
00
2
03
SU30
4
0
D4
00CB
c
(
Shown
)
R
U30
4
0
D4
00CL
c
R
U30
4
0
D4
00CK
c
7.
50
1
91
41.2
5
1
0
4
8
2
8
.2
5
71
8
C
,
D
,F
A
B
,C
Bl
a
nk En
d
W
a
l
l
SU30
4
0
D
300C
B
c
SU30
4
0
D4
00CN
c
Knockouts
Symbol ABCDEFGH I J
Conduit Size
(inches) 123411
1411222
1233
124
aNote 1:
Driphood supplied factory-installed
and is required for surface mount
installation.
For semi-flush installation, remove
driphood and install flange kit, catalog
number: SC200F (order separately).
7.14
181
14.97
380 “A” Hub
Drip Hood
bNote 2:
Unit supplied with blank top endwall (factory-
installed) for surface mount installation. For
semi-flush installation, install flange kit, catalog
number FK400 (order separately). Kit includes
replacement top endwall (with knockouts) and
flanges.
C,D,F A
B,C,D
7.50
191
Semi-Flush End Wall
28.28
718
LOAD CENTERS
29
Enclosed Molded Case Switches, Enclosed GFCI
Circuit Breakers, Circuit Breaker Enclosures
Class 1131
© 2004 Schneider Electric
All Rights Reserved
6/7/04
www.SquareD.com
For the most up-to-date information
Enclosed Molded Case SwitchesUL Listed
Molded Case Switch Included. Does not provide overcurrent
protection.
Service Ampere
Rating
General Purpose Rainproof Box No.
See Page
19, 20
Catalog No. Price Catalog No. Price
240 Vac
60 ab QO260NATS $107.00 QO200TR $112.00 2, 9R c
120/240 Vac
100 dQO2000NS 184.00 QO2000NRB 225.00 13,10R
Housing Bracket
Description Catalog No. Price
Bracket used with QO200TR for stucco, aluminum and vinyl siding.
Order quantity multiples of 10. PKHB $2.10
Enclosed GFCI Circuit BreakersUL Listed
2-pole, 120/240 Vac, GFCI circuit breaker included, 10,000 AIR
Service Ampere
Rating
Type 3R—Rainproof Circuit Breaker
Included
Box. No.
See Page
20
Catalog No. Price
120/240 Vac
50 QOE250GFINM
HOME250SPA
$352.
315.
QO250GFI
HOM250GFI
1NM (Non-metallic)
1R (Metallic)
Circuit Breaker EnclosuresUL Listed
22,000 RMS Symmetrical Ampere Short Circuit Current Rating. Not for use with one pole
QO circuit breakers. Circuit breakers not included. Order QO®, QO-GFI, QO AFI, QO-EPD
and QO-PL circuit breakers separately from pages 3 and 4. Accepts QO circuit breakers
with factory-installed accessories. Order equipment ground bar PK0GTA2, if required.
Service Ampere
Rating
General Purpose eRainproof Box. No.
See Page
19, 20
Catalog No. Price Catalog No. Price
120/240 Vac
100
125
QO2100BNF/S
QO2125BNF/S
$55.00
72.00
QO2100BNRB
QO2125BNRB
$90.00
105.00
13, 10R
18, 13R
240 Vac
100 QO3100BNF/S 99.00 QO3100BNRB 138.00 13, 10R
10,000 RMS Symmetrical Ampere Short Circuit Current Rating.
Circuit breaker not included. Order separately from page 3. Will not accept QO-GFI
circuit breaker nor QO circuit breakers with factory-installed accessories.
240 Vac
60 a. . . . . . . . QO2TR $63.00 9R c
QO2000NS QO3100BNF
With Cover Removed
DE2A rDE3A Discount
Schedule
Q Frame Enclosures and Q Frame Circuit Breakers—UL Listed
Service
Enclosure OnlygCircuit Breaker (Order Separately)
Type 1—General Purpose eType 3R—Rainproof Box No.
See Page
19, 20
Ampere
Rating
10,000 AIR 25,000 AIR 65,000 AIR 100,000 AIR
Catalog No. Price Catalog No. Price Cat. No. Price Cat. No. Price Cat. No. Price Cat. No. Price
2-pole 240 Vac
Maximum
Q22200NS h
or
Q23225NF/S
$117.00
145.00
Q22200NRBh
or
Q23225NRB
$253.00
278.00
19, 11R
20, 12R
70 QBL22070 $316. QDL22070 $762. QGL22070 $1014. QJL22070 $1260.
80 QBL22080 316. QDL22080 762. QGL22080 1014. QJL22080 1260.
90 QBL22090 316. QDL22090 762. QGL22090 1014. QJL22090 1260.
100 QBL22100 316. QDL22100 762. QGL22100 1014. QJL22100 1260.
110 QBL22110 316. QDL22110 762. QGL22110 1014. QJL22110 1260.
125 QBL22125 316. QDL22125 762. QGL22125 1014. QJL22125 1260.
150 QBL22150 316. QDL22150 762. QGL22150 1014. QJL22150 1260.
175 QBL22175 316. QDL22175 762. QGL22175 1014. QJL22175 1260.
200 QBL22200 316. QDL22200 762. QGL22200 1014. QJL22200 1260.
225 QBL22225 316. QDL22225 762. QGL22225 1014. QJL22225 1260.
3-pole 240 Vac
Q23225NF/S 145.00 Q23225NRB 278.00 20, 12R
70 QBL32070 832. QDL32070 1189. QGL32070 1628. QJL32070j1864.
80 QBL32080 832. QDL32080 1189. QGL32080 1628. QJL32080j1864.
90 QBL32090 832. QDL32090 1189. QGL32090 1628. QJL32090j1864.
100 QBL32100 832. QDL32100 1189. QGL32100 1628. QJL32100j1864.
110 QBL32110 832. QDL32110 1189. QGL32110 1628. QJL32110j1864.
125 QBL32125 832. QDL32125 1189. QGL32125 1628. QJL32125j1864.
150 QBL32150 832. QDL32150 1189. QGL32150 1628. QJL32150j1864.
175 QBL32175 832. QDL32175 1189. QGL32175 1628. QJL32175j1864.
200 QBL32200 832. QDL32200 1189. QGL32200 1628. QJL32200j1864.
225 QBL32225 832. QDL32225 1189. QGL32225 1628. QJL32225j1864.
aNot suitable for service equipment.
bMaximum 10 hp 240 Vac.
cTop endwall has no hub opening.
dMaximum 20 hp 240 Vac.
eOrder F for flush, S for surface.
fEquipment ground bar kit PKOGTA2 factory-included.
gFactory-installed groundable neutral assembly includes (2) ground lugs and (2) neutral lugs.
Equipment ground kit PKOGTA2 also included.
hAccepts 200 A max. 2-pole Q Frame circuit breakers.
iAdd suffix 1021 for 120, 208 or 240 Vac shunt trip. Add $126.
jWhen these 3-pole circuit breakers are mounted in an enclosure, the maximum AIR rating is 65,000 at 240 Vac and
100,000 at 208 Vac.
QOM2 Enclosures and QOM2 Circuit Breakers—UL Listed
Service
Enclosure OnlyfQOM2 Circuit Breaker
(Order Separately) i
Type 1
General Purposee
Type 3R
Rainproof Box No.
See
Pages
19, 20
Ampere
Rating
22,000 AIR
Catalog No. Price Catalog No. Price Catalog No. Price
r
2-pole 240 Vac
Maximum
QOM22225NF/S $156. QOM22225NRB $293. 22, 16R
100 QOM2100VH $312.
125 QOM2125VH 312.
150 QOM2150VH 312.
175 QOM2175VH 312.
200 QOM2200VH 312.
225 QOM2225VH 312.
QOM22225NS Q22200NS Q23225NF
With Cover With Cover Removed
Removed
(Order Q Frame circuit breaker separately)
Surge
PROTECTION
30
Surgebreaker®secondary surge arresters
The Surgebreaker secondary surge arrester is available for both
QO®and Homeline®load centers. These surge arresters plug onto the
load center bus bars like a circuit breaker and provide protection from high
voltage surges. The Homeline Surgebreaker surge arrester can be used in
Square D All-In-Ones and Meter Mains.
Surgebreaker Plus Whole House
Surge Protector
The Surgebreaker Plus Whole House Surge Protector from
Square D is ideal for protecting electrical circuits, multiple telephone lines
and multiple TV lines in today’s electronic home.
UL listed 1449, 2nd edition.
$50,000 Warranty.
Suitable for use in service entrance locations: meets requirements of
NEC Article 280.
Suitable for indoor applications only.
LED Status Indicator.
Flush or surface mounting.
Electrical System - Connects through the main load center.
Two coax lines - Master antenna, satellite dish or cable.
Four line telephone (Digital/Analog POTS) protection.
LOAD CENTERS
31
Surge Protective Devices
TVSS and Surge Arresters
Class 6671
© 2004 Schneider Electric
All Rights Reserved
6/7/04
www.SquareD.com
For the most up-to-date information
SURGEBREAKER®PLUS
Transient Voltage Surge Suppressor
Suitable for use in service entrance locations; meets
requirements of NEC® Article 280, UL Listed 1449, 2nd
Edition, and meets ANSI/IEEE C62.41-1991.
AC line protection
Four line telephone (Digital/Analog POTS) protection
Two line coaxial protection
Suitable for indoor applications only
Flush or surface mounting
LED status indicator
Modular design
SURGEBREAKER
Secondary Surge Arrester
Suitable for use in service entrance locations; meets
requirements of NEC Article 280.
CULUS Listed secondary surge arresters;
QO2175SB also CSA Certified
Meet ANSI/IEEE C62.11-1993
QO2175SB for QO® load centers and combination
devices, NQOD panelboards
HOM2175SB for HOMELINE® load centers and
combination devices
Plug-on design requires two pole spaces
LED indicates operational status
Hard-Wired Secondary Surge Arrester
Suitable for use in service entrance locations; meets
requirements of NEC Article 280.
CULUS Listed and CSA Certified secondary surge
arresters
Meet ANSI/IEEE C62.11-1993
Suitable for indoor and outdoor applications
LED indicates operational status
aSee page 13 for QOSAMK mounting kit for installation in QO load centers.
bDo not use on ungrounded systems. Systems must be solidly grounded.
Single Phase Three Wire—120/240 Vac
Description Catalog
Number Price
SURGEBREAKER PLUS SDSB1175C $420.
Description Catalog
Number Price
QO SURGEBREAKER
CULUS Listed Secondary Surge Arrester
150 Vac line-to-ground maximum.
QO2175SB $106.
HOMELINE SURGEBREAKER
CULUS Listed Secondary Surge Arrester
150 Vac line-to-ground maximum.
HOM2175SB 106.
Description Catalog
Number Price
SECONDARY SURGE ARRESTER
For 1Ø3W systems.
150 Vac phase-to-ground maximum.
SDSA1175 a$61.
SECONDARY SURGE ARRESTER
For 3Ø systems.
600 Vac phase-to-ground maximum.b
SDSA3650 165.
SDSB1175C
QO2175SB
HOM2175SB
SDSA1175
SDSA3650
BlackWhite
Black
One SDSA1175 on
120/240 Vac Circuit
Black
White White
Black Blac
k
Two SDSA1175 on
208Y/120 Vac Circuit
Blac
k
White
Black
Black
3Ø4W
208Y/120 Vac
480Y/277 Vac
600Y/347 Vac
White
Black
Black
Blac
k
3Ø4W
240/120 Vac
White
Blac
k
Black
Black
3Ø3W
G
rounded B Phase)
240 Vac
480 Vac
DE1B Discount
Schedule
For additional information, reference Catalog #6671CT9701R2/02.
Air Conditioning
DISCONNECT
Air Conditioning Disconnects
No air conditioning electrical protection system is complete without a
Square D air conditioning disconnect. Our disconnects are available in
a variety of configurations that let you choose the best product for your
particular application. These include molded case switch, fused, and
non-fused switches.
Enclosed Molded Case Switch
Cover housing can be removed to provide open access to lugs for
easy wiring.
60 A switch rated for 10 hp motors at 240 Vac.
Factory installed ground bar is located in front for easy access.
Open area for mounting allows plenty of room for power actuated tool.
Dimples accommodate nailer.
Fusible and Not Fusible Pullout Switches
Interior trim cannot be removed unless the pull-out head is completely
disengaged or placed in the OFF position.
Pull-out head can be replaced in the OFF position.
30 A and 60 A fusible, and 60 A not fusible ratings,
up to 10 hp at 240 Vac.
32
LOAD CENTERS
33
Air Conditioning Disconnects
Class 3150
© 2004 Schneider Electric
All Rights Reserved
6/7/04
www.SquareD.com
For the most up-to-date information
aDoes not contain overcurrent protection. Suitable for use on systems with up to 10,000 RMS symmetrical amperes
available fault current at 240 Vac max when protected by a fuse or circuit breaker rated 60 A or less.
bSuitable for use on systems with up to 10,000 RMS symmetrical amperes available fault current at 240 Vac.
Not Fusible Air Conditioning Disconnect—Molded Case Switch
Rainproof—UL Listed
Service Ampere
Rating a
Metallic Non-metallic
Max. Hp
Catalog
Number Price Catalog
Number Price
2 Wire (Molded Case Switch Included)—240 Vac Maximum
60 QO200TR $107.00 QO200TRNM $127.00 10
Housing Bracket
Description Catalog No. Price
Bracket used with QO200TR for stucco, aluminum and vinyl siding.
Order quantity multiples of 10. PKHB $2.10
Not Fusible Air Conditioning Disconnect—Pullout
Rainproof—UL Listed
Service Ampere
Rating a
Metallic Non-metallic
Max. Hp
Catalog
Number Price Catalog
Number Price
2 Wire—240 Vac Maximum
60 UFP222R $113.00 UFP222RNM $127.00 10
2 Wire—240 Vac Maximum—with 20 A GFI receptacle
60 UFP222RGFI $303.00 . . . . . . 10
2 Wire—240 Vac Maximum—with 20 A duplex receptacle
60 UFP222RD $173.00 . . . . . . 10
Fusible Air Conditioning Disconnect—Pullout
Rainproof—UL Listed
Service Ampere
Rating b
Metallic Non-metallic
Max. Hp
Catalog
Number Price Catalog
Number Price
2 Wire (Pullout and Fuseholder)—240 Vac Maximum
30 FP221R $107.00 FP221RNM $127.00 3
60 FP222R 107.00 FP222RNM 127.00 10
Note: Suitable for use as service equipment on 120/240 Vac 1Ø3 wire services if used only on a 1Ø2 wire load; and
only when the equipment grounding terminal is replaced with ground terminal kit catalog number PK3GTA1.
Price $7.60.
Box Dimensions
Catalog
Number
HWD
IN mm IN mm IN mm
QO200TR 4.63 117 6.50 165 3.88 98
QO200TRNM 8.75 222 6.50 165 3.88 98
UFP222R 5.25 133 7.50 191 3.25 83
UFP222RNM 8.75 222 6.50 165 3.88 98
FP221R 5.25 133 7.50 191 3.25 83
FP221RNM 8.75 222 6.50 165 3.88 98
FP222R 5.25 133 8.88 225 3.25 83
FP222RNM 8.75 222 6.50 165 3.88 98
QO200TR
QO200TRNM
G/B
PKHB
Housing
Bracket
G/B
G/B
GFI Rec.
Duplex Rec.
G/B
FP221R
G/B
DE2A Discount
Schedule
LOAD CENTERS
www.SquareD.com
For the most up-to-date information
34
SERVICEPAK® Power Outlet Panels
Class 1140
© 2004 Schneider Electric
All Rights Reserved
6/7/04
For Construction Sites
Provide temporary power at construction sites.
Each receptacle protected by QO-GFI circuit breaker in compliance with NEC®
requirements.
Each enclosure is rainproof.
10,000 RMS symmetrical ampere short circuit current rating.
UL Listed as suitable for use as temporary site service equipment.
Provided with neutral bonding provisions.
Boxes have provisions for type “B’ hubs to be field-installed.
For Recreational Vehicle Parks
Provide electrical power to individual recreational vehicle park sites.
Each receptacle protected by appropriate GFI or Standard QO® circuit breaker.
All receptacles and circuit breakers included.
10,000 RMS Symmetrical Ampere short circuit current rating. UL Listed.
All enclosures are rainproof. No neutral bonding provisions. Loop-feed provisions.
a(1Ø2W 120 Vac) (1Ø3W 120/240 Vac)
b20 ampere receptacles protected by 20 ampere GFI circuit breaker.
cDevices have a bolt-on factory-installed closing cap. Order type "B’’ bolt-on hub separately from page 20.
dEquipment Ground Terminal suitable for (2) #14 or 12 AWG Cu or (2) #12 or 10 AWG Al.
eReceptacles in this device are in bottom endwall and are accessible with outer door padlocked.
"Order Only’ from Lexington—Minimum order quantity is 50 devices.
fTwo wires each per phase, neutral, and equipment ground—for loop feed (except PAK75CTG).
gEquipment ground terminal suitable for (2) #14–12 AWG Cu or (2) #12–10 Al.
hGFI circuit breaker can be substituted for standard 30 A circuit breaker. For 30 ampere receptacles add $140.00 per circuit
breaker.
Add suffix "FI’ to catalog number. Example: PAK41CTGFI.
iStabilizer foot available for use in unstable ground, order catalog number HNPSF $27.50 list.
jEquipment ground terminals suitable for (2) #10–2/0 AWG Cu or (2) #6–2/0 AWG Al.
Power
Outlet
Configuration
Service
a
Mains
Ampere
Rating
Circuit Breaker
(Included)
Receptacles
(Included) bCatalog
Number
c
Price
Main Wire Size
AWG d
ACDEF Cu Al
1C 1Ø2W 40 (1) QO120GFI 1 PAK10C1 $294. #14–6 #12–6
2C 1Ø2W 40 (2) QO120GFI 2 PAK11Ce 545. #14–6 #12–6
2C 1Ø2W 40 (2) QO120GFI 2 PAK11C1 545. #14–6 #12–6
3C 1Ø3W 70 (1) QO120GFI
(1) QO230GFI 11PAK31CGFI 649. #8–1 #8–1
4C 1Ø3W 70 (1) QO120GFI
(1) QO220GFI 11 PAK36C1GFI 649. #8–1 #8–1
5C 1Ø3W 70 (1) QO120GFI
(1) QO250GFI 11PAK51CGFI 649. #8–1 #8–1
6C 1Ø3W 70 (1) QO120GFI
(1) QO250GFI 11 PAK55CGFI 649. #8–1 #8–1
7C 1Ø3W 70 (2) QO120GFI
(1) QO220GFI 21 PAK72CGFI 882. #8–1 #8–1
8C 1Ø3W 70 (2) QO120GFI
(1) QO250GFI 21 PAK76CGFI 882. #8–1 #8–1
9C 1Ø3W 100 (1) QO120GFI
(2) QO250GFI 12 PAK1004CGFI 1054. #14–1 #12–1
Power Outlet
Configuration
Service
a
Mains
Ampere
Rating
Circuit Breaker
(Included)
Receptacles
(Included) bCatalog
Number Price
Main Wire Size
AWG/kcmil f
Phase and Neutral
ABC Cu Al
Underground or Overhead Loop-Feed Terminals—Non-Pedestal cg
10C 1Ø2W 40 (1) QO120GFI 1 PAK10CTG $313.
#14–6 #12–6
11C 1Ø2W 40 (2) QO120GFI 2 PAK11CTG 530.
12C 1Ø2W 50 (1) QO120GFI
(1) QO130 11 PAK41CTG h376.
13C 1Ø2W 75 (1) QO120GFI
(2) QO130 12 PAK61CTG h435.
#14–1 #12–1
14C 1Ø3W 100
(1) QO120GFI
(1) QO250
(1) QO130
111
PAK75CTG
(Not Loop Feed)h446.
Pedestal Mounted—Underground Loop-Feed Terminalsij
11C 1Ø2W 40 (2) QO120GFI 2 PAK11PG $690.
(2)#6–250 (2)#6–250
12C 1Ø2W 50 (1) QO120GFI
(1) QO130 11 PAK41PG h568.
13C 1Ø2W 75 (1) QO120GFI
(2) QO130 12 PAK61PG h609.
14C 1Ø3W 100
(1) QO120GFI
(1) QO250
(1) QO130
111PAK75PG h671.
T
T
TT T
T
T T
TT
TT TT
TTT
T T
T
TT
T
1C 2C 3C
4C 5C 6C
8C
TT T
7C 9C
10C 11C 12C
13C 14C
All non-pedestal devices have provisions to
field-install a Type “B’ hub on the bottom
endwall for bottom feed from a conduit riser.
Order Type “B’ bolt-on hub (B250 Max.) and
two mounting screws (Part No. 8002505501)
and two hex nuts (Part No. 2340102000).
20 Amp 125 Volt 2W and Grd.
NEMA 5-20R
30 Amp 125 Volt 2W and Grd.
ANSI #73.13
50 Amp 125/250 Volt 3W and Grd.
NEMA 14-50R
20 Amp 250 Volt 2W and Grd.
NEMA 6-20R
30 Amp 125/250 Volt 3W and Grd.
NEMA 14-30R
50 Amp 250 Volt 2W and Grd.
NEMA 6-50R
A
B
C
D
E
F
DE4 Discount
Schedule
Structured Wiring
A NEW OPPORTUNITY
TO INCREASE YOUR
SALES PER HOME
The Square D Multi-Link Structured Wiring System devices organize the
way a house is wired to coordinate telephone, video, and data
services for unmatched flexibility and convenience. Installed during
construction, these devices increase capabilities without adding
significant cost to the home.
Pre-wiring with standard Cat-5 and RG-6 cables will ensure that the
home is wired to meet the demands of today and the future innovations of
tomorrow. Square D Multi-Link Structured Wiring System provide the
enclosures and brackets to install the video, voice, audio and data hubs
along with the accessories and upgrade options to bring the home into
the telecommunication and entertainment future.
35
Application: Residential and light commercial
New multi-family and single-family construction
Standards: UL 1492, Audio/Video Products and Accessories
UL 514A, Metallic Outlet Boxes
UL 1863, Communications Circuit Accessories
Federal Regulation 47CFR15.115
TIA/EIA 570-A, Residential Telecommunications
Cabling Standard
Enclosures: NEMA Type 1
Surface or flush mount
Construction: Modules mount on enclosure grid via “hook and
swing” method
All modules incorporate a metal backplate for
strength and rigidity
Data and telephone modules available with either
110 punch down terminations or RJ-45 modular plugs
Accessories: AC power accessories, universal adapter brackets, patch
cords, cover lock kit, video attenuators, low pass filters.
LOAD CENTERS
www.SquareD.com
For the most up-to-date information
36
Square D Multi-Link Structured Wiring System
Class 1400
© 2004 Schneider Electric
All Rights Reserved
6/7/04
DE7 Discount
Schedule
The Square D Multi-Link Structured Wiring System devices organize the way a house is
wired to coordinate telephone, video, and data services for unmatched flexibility and
convenience. Installed during construction, these devices increase capabilities without
adding significant cost to the home.
aTwo columns of grid mounting space, 17" of space per column.
bTwo columns of grid mounting space, 35" of space per column.
System Components
Description Catalog
Number Price
Grid
Mounting
Space (IN)
Standard
Package
Mounting Brackets and Enclosures
Surface mounting bracket, 6 1/2"w x 10"h, white SDM10BW $15.20 10 10
Cover for SDM10BW, white SDM10CW 28.60 . . . 1
Enclosure w/mounting grid, 14"w x 18"h, white SDM18BW 44.60 34a1
Cover for SDM18BW, white SDM18CW 16.30 . . . 1
Enclosure w/mounting grid, 14"w x 36"h, white SDM36BW 86.00 70b1
Cover for SDM36BW, white SDM36CW 28.00 . . . 1
Combination Video/Telephone Hubs
Combo hub, video splitter (1 input x 4 TVs) / phone
(2 lines x 6 phones), grid mount SDM26P14V 58.00 31
Combo hub, video splitter (1 input x 4 TVs) / phone
(4 lines x 6 phones), grid mount SDM46P14V 77.00 31
Telephone Hubs
Telephone master hub, 4 lines x 6 phones, grid mount SDM46P 58.00 31
Telephone expansion hub, 4 lines x 8 phones, grid mount SDM48PX 58.00 31
Telephone interface hub, 4 lines x 11 phones, grid mount,
RJ45 jacks SDM412PJ 74.00 31
Video Hubs
Video splitter, (1 input x 3 TVs), grid mount SDM13VS 19.10 21
Video splitter, (1 input x 4 TVs), grid mount SDM14VS 22.90 21
Video splitter, (1 input x 8 TVs), grid mount SDM18VS 42.00 21
Video amplifier hub (1 input x 6 TVs), bi-directional CATV
or antenna, grid mount, 120 Vac power supply included SDM16VAB 96.00 31
Video amplifier hub (3 inputs x 8 TVs), bi-directional
CATV, IR repeating system, grid mount, 120 Vac power
supply included
SDM38VBIR286.00 2.5 1
Video amplifier hub (3 inputs x 8 TVs), CATV or antenna,
IR repeating system, grid mount, 120 Vac power supply
included
SDM38VHIR286.00 2.5 1
Modulators
Single channel modulator, RCA inputs, grid mount, 120
Vac power supply included SDM11VM 248.00 2.5 1
Single channel combination modulator, amplifier. Cat-5
input for modulation, combined with amplified coax input
for bi-directional CATV, grid mount, 120 Vac power supply
included
SDM11VMB 286.00 2.5 1
Single channel combination modulator, amplifier. Cat-5
input for modulation, combined with amplified coax input
for CATV or antenna, grid mount, 120 Vac power supply
included
SDM11VMH 286.00 2.5 1
Set top mount dual channel modulator, RCA inputs, IR
repeating system, 120 Vac power supply included SDM21VT 372.00 . . . 1
Set top mount quad channel modulator, RCA inputs, IR
repeating system, 120 Vac power supply included SDM41VT 563.00 . . . 1
Set top mount dual channel MTS stereo modulator, RCA
inputs, IR repeating system, 120 Vac power supply
included
SDM21VTST 667.00 . . . 1
Set top mount quad channel MTS stereo modulator, RCA
inputs, IR repeating system, 120 Vac power supply
included
SDM41VTST 1122.00 . . . 1
Modulator combiner hub (8 input x 1 output), grid mount,
use with Video Hub SDM38VHIR/SDM38VBIR, 120 Vac
power supply included
SDM81VC 172.00 2.5 1
Cat-5 Video Wall Plate, use with SDM11VMB/
SDM11VMH if modulating from a source with RCA
outputs
SDM1VWP 67.00 . . . 1
Satellite Hub
Satellite TV multi-switch, connects 4 satellite receivers to
a dual LNB dish, grid mount SDM24VD 133.00 2.5 1
Audio Hub
Speaker distributon hub (stereo), distributes 1 audio
source to six rooms, grid mount SDM16A 63.00 31
SDM18CW and SDM18BW
SDM46P14V
SDM46P
SDM38VBIR/SDM38VHIR
SDM11VMH/SDM11VMB
For additional information, reference Catalog #1400CT0101R3/03.
LOAD CENTERS
37
Square D Multi-Link Structured Wiring System
Class 1400
© 2004 Schneider Electric
All Rights Reserved
6/7/04
www.SquareD.com
For the most up-to-date information
DE7 Discount
Schedule
aRequires 7" of grid mounting space per column, 14" total.
bRequires 5.5" of grid mounting space per column, 11" total.
cSpace required is dependent upon size of the device utilizing the mounting bracket.
System Components, continued
Description Catalog
Number Price
Grid
Mounting
Space
(IN)
Standard
Package
Data Hubs
Data termination hub provides termination point for Cat-5
wiring, 100 Base-T certified, 8 bridgeable circuits
(8 - 110 punch down blocks connected to 8 - RJ-45 jacks)
SDM8D $67.00 31
Data termination hub provides termination point for Cat-5
wiring, 100 Base-T certified, 16 bridgeable circuits (16 -
110 punch down blocks connected to 8 - RJ-45 jacks)
SDM8DB 87.00 4.5 1
Ethernet hub, 10 Base-T certified, 5 - RJ-45 ports, uplink
port, grid mount, 120 Vac power supply included SDM5DE 114.00 41
Router hub, 10/100 Base-T certified, 7 - RJ-45 ports, grid
mount, integral 120 Vac power supply SDM7DR 374.00 14a1
Video Cameras
B&W, single gang in-wall, 0.3 lux, fixed aim, used with
and powered by SDM11VMB/SDM11VMH modulator via
Cat-5 wiring
SDM1VC 229.00 . . . 1
Color, single gang in-wall, 6 lux, fixed aim, used with
and powered by SDM11VMB/SDM11VMH modulator via
Cat-5 wiring
SDM1VCC 457.00 . . . 1
B&W, double gang in-wall, 2 lux, adjustable aim, used
with and powered by SDM11VMB/SDM11VMH
modulator via Cat-5 wiring
SDM2VC 343.00 . . . 1
Color, double gang in-wall, 8 lux, adjustable aim,
used with and powered by SDM11VMB/SDM11VMH
modulator via Cat-5 wiring
SDM2VCC 533.00 . . . 1
IR Controls
IR remote control target, coaxial in/out, locate at televi-
sion SDM1VIR82.00 . . . 1
IR remote control emitter, locate at video source SDM2VIR20.40 . . . 1
Wall Plates
White wall plate 4 phone and 2 video SDM10PVWPW 19.70 . . . 10
White wall plate 1 data, 2 phone and 2 video SDM10DPVWPW 17.40 . . . 10
Almond wall plate 4 phone and 2 video SDM10PVWPA 19.70 . . . 10
Almond wall plate 1 data, 2 phone and 2 video SDM10DPVWPA 17.40 . . . 10
Ivory wall plate 4 phone and 2 video SDM10PVWPI 19.70 . . . 10
Ivory wall plate 1 data, 2 phone and 2 video SDM10DPVWPI 17.40 . . . 10
Accessories
AC outlet accessory, mounts in enclosures, 2 duplex
receptacles (not included) accepts 2 power supplies,
UL Listed, 120 Vac
SDM4AC 30.50 5.5 1
AC outlet accessory, mounts in enclosures, 4 duplex
receptacles (not included) accepts 4 power supplies,
UL Listed, 120 Vac
SDM8AC 36.50 11b1
Adapter bracket to mount ChannelPlus 3400 or 8200 on
Square D Multi-Link grid SDM1A 19.10 21
Adapter bracket to mount RJ and type F connectors on
Square D Multi-Link grid SDM6A 19.10 21
Wire Spacer Mezzanine, Universal Grid, lifts modules 1"
above grid, providing wire management capabilities,
11.2"h x 6.5"w
SDM12WS 29.20 12 1
Universal heavy duty isolation mounting bracket for non-
Square D Multi-Link products. Load rated 60 pounds. SDM1IMB 58.00 c1
Universal light duty isolation mounting bracket for non-
Square D Multi-Link products. Load rated 10 pounds. SDM2IMB 28.60 c1
Patch Cord 1 foot length, Cat-5, RJ-45 plugs on both ends SDM1DC 7.70 . . . 1
Patch Cord 2 foot length, Cat-5, RJ-45 plugs on both ends SDM2DC 9.60 . . . 1
Enclosure Coupling Tube for stacking enclosures, 2 inch
conduit SDM2C 15.20 . . . 1
Plastic grommet for 2" enclosure knockout, (5) pack SDM2G 2.90 . . . 1
Cover Lock Kit SDMLK 29.20 . . . 1
Replacement snap locks, lock Square D Multi-Link
modules to grid, black (10) pack SDM10SL 11.40 . . . 1
Attenuator, 3 dB SDM2503 2.70 . . . 10
Attenuator, 6 dB SDM2506 2.70 . . . 10
Low Pass Filter, Channel 91 SDM600LPF 38.90 . . . 1
SDM8D
SDM2VC/SDM2VCC
SDM1VC/SDM1VCC
SDM18BW with optional modules
For additional information, reference Catalog #1400CT0101R3/03.
Metering
Metering Equipment
Schneider Electric provides the most reliable and most versatile line
of metering equipment in the industry for residential and commercial
applications.
As fewer utilities provide meter sockets it’s important to have one reliable
source that meets all your needs. From individual meter sockets to
multi-metering centers there’s no better choice than Square D.
Individual and Horizontal ganged meter sockets
Meter-Pak and EZ Meter-Pak multi-metering equipment
Individual Meter Sockets
Square D individual meter sockets have provisions to feed a downstream
main lug load center (with a maximum of 6 service disconnects), main
breaker load center, or an individually enclosed service disconnect. 400
ampere, studs only units have provisions for mounting dual load side lugs
to feed two downstream main breaker load centers or two individually
enclosed disconnects.
EZ Meter-Pak®Multi-Metering Equipment
These exclusive Square D Meter Centers not only make it easier to install
multi-unit metering equipment, but also provide a more economical option
than separately purchasing individual meter sockets.
EZ Meter-Pak meter center enclosures meet NEC wire bending
requirements, and are designed for wall mounting only (not suitable for
floor mounting). All unmetered conductor compartments are sealable by
the utility company.
THE WIDEST SELECTION
IN THE INDUSTRY
38
METERING EQUIPMENT
39
Metering
Individual Meter Sockets
Class 4131
© 2004 Schneider Electric
All Rights Reserved
6/7/04
www.SquareD.com
For the most up-to-date information
DE4 Discount
Schedule
Individual Meter Sockets—Ring and Ringless Type
Available single or three phase, 600 Vac max., with and without horn or lever bypass, overhead and underground
service feed.
10,000 RMS symmetrical amperes short circuit current rating (or higher with utility approval).
UL Listed, NEMA 3R enclosure.
Units supplied with bonded neutral.
Units supplied with hub opening in top endwall require the use of a bolt-on hub, or closing plate.
Units supplied with solid top are for underground feed only.
Accessories, refer to page 40.
aDevice requires approval from the serving utility, consult your nearest Square D/Schneider Electric sales office.
bOrder appropriate bolt-on hub or closing plate separately and install on TOP endwall.
cDevice supplied with 1-1/4" bolt-on hub (Cat.No. A125) mounted on TOP endwall.
dDevice supplied with solid top endwall (without hub opening).
eWhen unit is installed for underground feed, the appropriate closing plate must be ordered separately and installed over hub opening in TOP endwall of device.
fDevice supplied with closing plate (Cat. No. ACP) mounted on TOP endwall.
gDevice supplied with two closing plates (Cat. No. ACP) mounted in TOP endwall.
hContains “Duquesne Light Co.” approved label.
iOrder lugs separately, refer to accessories, page 40.
j Device supplied with stainless steel, snap-on sealing ring.
This metering is generally utility specific. Always check with local utility company before installing.
Contact your nearest Square D/Schneider Electric sales office for additional catalog numbers, if required by utility.
Ampere
Rating
(Cont.)
Jaw
Qty.
Service
Type
Catalog
Number
a
Price
Lug Wire Range (Al/Cu) Enclosure Information Box
No.
see
page
41
Line, Load,
and Neutral
(AWG/kcmil)
Wire
Binding
Gnd.
(AWG) Material
Top Endwall Conf.
Hub
Openingb
Closing
Plate b
Ringless Type, 1-Phase, 3-Wire 600 Vac Max., Without Bypass or Jaw Release
125 4 UG UTZRS101Ad$82.00 #8–2/0 1/2" HEX #14–2 Steel Solid Topd. . . 1R
125 4 OH UTRS101B 82.00 #8–2/0 SLOTTED #14–2 Steel Series A ACP 1R
125 4 OH UATRS101B 91.00 #8–2/0 SLOTTED #14–2 Aluminum Series A ACPA 1R
125 4 OH URS101BCPL 90.00 #8–2/0 SLOTTED #14–2 Steel Series A ACP 1R
125 5 OH/UG 1003880Ae107.00 #8–2/0 SLOTTED #14–2 Steel Series A ACP 1R
200 4 OH UTRS202B 118.00 #8–250 1/2" HEX #14–2 Steel Series A ACP 3R
200 4 OH UATRS202B 130.00 #8–250 1/2" HEX #14–2 Aluminum Series A ACPA 3R
200 4 UG UTRS213Ad141.00 #1/0–350 1/2" HEX #14–2 Steel Solid Topd. . . 5R
200 4 OH/UG UTRS213Be141.00 #1/0–350 1/2" HEX #14–2 Steel Series A ACP 5R
200 4 OH/UG UATRS213Be150.00 #1/0–350 1/2" HEX #14–2 Aluminum Series A ACPA 5R
200 4 OH/UG U92197CCCPL g160.00 #1/0–350 1/2" HEX #14–2 Steel (2)Series A (2)ACPg7R
Ringless Type, 1-Phase, 3-Wire 600 Vac Max., With Horn Bypass, Without Jaw Release
125 4 OH/UG UHTRS101B 107.00 #8–2/0 SLOTTED #14–2 Steel Series A ACP 1R
125 5 OH UGHTRS101Lc107.00 #8–2/0 SLOTTED #14–2 Steel A125c . . . 1R
125 4 OH URS101BDQh92.00 #8–2/0 1/2" HEX None Steel Series A ACP 1R
125 5 OH/UG UGHTRS111Cf138.00 #8–2/0 SLOTTED #14–2 Steel Series A ACPf4R
200 4 OH/UG UBHMRS212Be140.00 #8–250 1/2" HEX None Steel Series A ACP 4R
200 4 OH UHTRS202B 137.00 #8–250 1/2" HEX #14–2 Steel Series A ACP 3R
200 4 OH/UG UHTRS212Be137.00 #8–250 1/2" HEX #14–2 Steel Series A ACP 4R
200 4 OH/UG UHTRS213Be142.00 #1/0–350 1/2" HEX #14–2 Steel Series A ACP 5R
200 4 UG UHTRS223Ad181.00 #1/0–350 1/2" HEX #14–2 Steel Solid Topd. . . 2R
200 4 UG URS212ADQdh 135.00 #8–250 1/2" HEX None Steel Solid Top . . . 4R
Ringless Type, 1-Phase, 3-Wire 600 Vac Max., With Lever Bypass and Jaw Release
200 4 OH UTH4203T 310.00 #6–350 1/2" HEX #14–2 Steel Series A-L ACPL 8R
200 4 OH/UG UTH4213Te319.00 #6–350 1/2" HEX #14–2 Steel Series A-L ACPL 9R
200 5 OH UTH5203T 329.00 #6–350 1/2" HEX #14–2 Steel Series A-L ACPL 8R
200 5 OH/UG UTH5213Te376.00 #6–350 1/2" HEX #14–2 Steel Series A-L ACPL 9R
320 4 OH/UG UTH4330Tei 499.00 Studs Only 3/8" dia. studs #14–1/0 Steel Series A-L ACPL 11R
Ringless Type, 3-Phase, 4-Wire 600 Vac Max., With Lever Bypass and Jaw Release
200 7 OH/UG UTH7213Te444.00 #6–350 1/2" HEX #14–2 Steel Series A-L ACPL 9R
320 7 OH UTH7300Ti553.00 Studs Only 3/8" dia. studs #14–1/0 Steel Series A-L ACPL 10R
Ringless Type, 3-Phase, 4-Wire 600 Vac Max., Bolt-On Socket Without Bypass
400 7 OH/UG UK7T ei 1615.00 Studs
Only
1/2–20"
dia. studs
1/2–20"
dia. studs Steel Series A-L ACPL 12R
400 7 OH/UG UAK7T ei 1785.00 Studs
Only
1/2–20"
dia. studs
1/2–20"
dia. studs Aluminum Series A-L ACPLA 12R
Ring Type, 1-Phase, 3-Wire 600 Vac Max., Without Bypass or Jaw Release
125 4 OH/UG URTRS101Bej $82.00 #8–2/0 SLOTTED #14–2 Steel Series A ACP 1R
200 4 OH/UG URTRS213Bej 141.00 #1/0–350 1/2" HEX #14–2 Steel Series A ACP 5R
UTRS101B
UTRS202B
(cover not shown)
UTH5203T
(cover not shown)
URTRS213B
METERING EQUIPMENT
www.SquareD.com
For the most up-to-date information
40
Metering
Ganged and Test Block Sockets and Accessories
Class 4131
© 2004 Schneider Electric
All Rights Reserved
6/7/04
Horizontal Ganged Meter Sockets
Single phase, 600 Vac max., main lugs only, 2 through 6 meter positions, with and without horn or lever
bypass, end or center feed, overhead and underground service feeds
10,000 RMS symmetrical amperes short circuit current rating (or higher with utility approval)
UL Listed, NEMA 3R enclosure
Supplied with ground lugs
Supplied with hub opening in top endwall, requires the use of a bolt-on hub, or closing plate
This metering is generally utility specific. Always check with local utility company before installing.
Contact your nearest Square D/Schneider Electric sales office for additional catalog numbers, if required by utility.
aFor Hubs and Closing Plates, see Accessories table below.
bFifth Jaw Kit available to convert 4-Jaw Socket to a 5-Jaw Socket. See Accessories table below.
cFor 120/240 Volt, Three-Wire, Single Phase Dwelling services see NEC Table 310-16 Note 3.
Ringless Type, 1-Phase, 3-Wire, 600 Vac Max., Without Bypass or Jaw Release
Branch Ratings
Mains
Rating
Catalog
Number Price
Main Lugs
Phase & Neutral
Al/Cu
(AWG/kcmil)
Branch Lugs
Phase & Neutral
Al/Cu (AWG)
Top Endwalla
Box No.
See
page 41
Amperes
(cont.)
Number
of Positions
Socket
Jaw
Qty.b
Service
Type
Hub Type
(Order
Separately)
Closing Plate
(Order
Separately)
100
2
4OH/UG
200 UT2R1121B $302. #6–250
#8–2/0 Series A ACP
13R
3205 UT3R1121B 373. #6–250 13R1
4205 UT4R1131B 440. #6–350 14R
5250 UT5R1131B 605. #6–350 15R
6300 UT6R1131Bc771. #6–350 16R
200
2
4OH/UG
205 UT2R2122B 431. #6–250
#8–250
Series A ACP 17R
4360 UT4R2352Tc737. #1/0–500 Series A-L ACPL 18R
5500 UT5R2392TU 922. #1/0–500 or Series A-L ACPL 19R
(2)#1/0–350
6620 UT6R2392TU 1032. #1/0–500 or Series A-L ACPL 20R
(2)#1/0–350
UT2R1121B
uDE1A DE4 Discount
Schedule
hOrder only. Not stocked in PDS. Order point: Lexington.
Meter Sockets Accessories
Description Catalog
Number Price
FIFTH JAW KIT
Converts a 4-jaw meter socket to a 5-jaw meter socket.
For use on meter sockets supplied without lever bypass
or jaw release only.
A5J $9.90
CLOSING PLATES (to seal hub openings)
For Series A (steel)
For Series A (aluminum)
For Series A-L (steel)
For Series A-L (aluminum)
ACP
ACPA
ACPL
ACPLA
8.90
7.90
12.20
11.00
HUBS (listed by conduit size)
Series A:
1.00 inch
1.25 inch
1.50 inch
2.00 inch
2.50 inch
Series A-L:
2.00 inch
2.50 inch
3.00 inch
3.50 inch
4.00 inch
Series B:
3.00 inch
A100
A125
A150
A200
A250
A200L
A250L
A300L
A350L
A400L
B300
22.60
22.60
22.60
31.90
40.40
55.00
58.00
74.00
76.00
79.00
124.00u
ADAPTER PLATE
To allow the use of a Series A Hub
on a device that is setup for a series A-L Hub.
AAP 22.50
LUG KITS
For use on meter sockets supplied with Line, Load,
and Neutral Studs only. Be sure to order enough lugs
for each device (a typical 1-Phase device requires 6 lugs).
Includes one, two-barrel lug (#6-250 kcmil) ARP00118h25.40
Includes one, single barrel lug (#4-600 kcmil) ARP00129h36.80
Includes three, two-barrel lugs (#6-350 kcmil) ARP00427h90.00
SEALING RING (Non-Standard)
Snap-on Stainless Steel
Latch-Type Stainless Steel
Screw Type Aluminum
ARP00026h
29008G
29008W
11.10
13.40
13.40
dRefer to page 50 to select main circuit breaker.
eRequires use of EZM125QOA adapter (order separately). Refer to page 50 for pricing.
fRefer to page 41 for box dimensions.
gRefer to circuit breaker listings for usable load lug wire sizes.
Surface Mount, Ring Type, Meter Main with Test Block Bypass
(Meets EUSERC Requirements)
Supplied with bondable neutral, suitable for use as service equipment. Suitable for
overhead or underground service. UL Listed File E6294.
System
(Incoming)
and
Service
(Outgoing)
Meter
Socket
Type
Ampere
Rating
(Max.)
Short
Circuit
Current
Rating
Catalog
NumberfPrice
Main
Circuit Breaker
Type
(Order
Separately)d
120/240 Vac
1Ø3W 5-Jaw 200 A 42k Max. EMT1225CB $2730.
2-pole,
Type
QB, QD,
QG, QJ, QOe,
QO-VHe
or QOHe
208Y/120 Vac
3Ø4W
or
240/120 Vac
3Ø4W Delta
7-Jaw 200 A 22k Max. EMT3225CB 3570.
3-pole,
Type QB, QD,
QG or QJ
EMT Terminal Datag
Line
Phase Lug
Wire Size
(AWG-kcmil)
Line
Neutral Lug
Wire Size
(AWG-kcmil)
Service
Ground Lug
Wire Size
(AWG-kcmil)
Equipment
Ground Lug
Wire Size
(AWG-kcmil)
Load
Neutral Lug
Wire Size
(AWG-kcmil)
#6–300 Al/Cu #6–350 Al/Cu #4–300 Al/Cu #6–300 Al/Cu #4–300 Al/Cu
EMT3225CB EMT3225CB
Without Covers
METERING EQUIPMENT
41
Metering
Individual, Ganged and Test Block Sockets
Dimensions
© 2004 Schneider Electric
All Rights Reserved
6/7/04
www.SquareD.com
For the most up-to-date information
aRefer to page 40 for closing plates and hubs.
bKnockout for ground conductor.
Knockout Information and Enclosure Dimensions
Dimensions (Inches)
Box
No. HWD Hub Opening
(Max. Conduit Size)a
1R 10.88 8.00 3.50 Series A
2R 13.00 13.00 4.94 Solid Top
3R 14.00 8.00 4.38 Series A
4R 14.00 11.00 4.38 Series A
5R 15.00 11.00 4.38 Series A
6R 15.50 8.00 4.36 Series A
7R 17.13 13.00 4.94 (2) Series A
8R 19.00 10.50 4.94 Series A-L
9R 19.00 13.00 4.94 Series A-L
10R 34.50 15.00 5.68 Series A-L
11R 36.62 15.00 5.68 Series A-L
12R 43.00 20.25 6.00 Series A-L
13R 14.12 24.31 4.50 Series A
13R1 14.12 32.50 4.50 Series A
14R 14.12 40.62 4.50 Series A
15R 14.12 48.75 4.50 Series A
16R 14.12 57.00 4.50 Series A
17R 14.12 24.31 5.38 Series A
18R 14.12 40.62 5.38 Series A-L
19R 14.12 54.75 5.38 (2) Series A-L
20R 14.12 63.00 5.38 (2) Series A-L
Knockouts
Symbol S ABCDEFGH I J
Conduit Size
(inches) 516 b123411
1411222
1233
124
DW
H
A,B,C,D,E
S
C,D,E,F
A,B,C,D
Hub
Opening
1R
A,B,C,D
Meter
Socket
DW
H
F,G,H
Solid
Top
2R
C,D,E,F,G
Meter
Socket
Offset
SA
EMT1200CB and EMT3200CB
Supplied with (2)
ACP Closing Plates.
Order A-Hubs
separately for
overhead service
feed.
7.50
191
22.44
570
40.00
1016 C,D,E (3 Locations)
E,F,G,H (8 Locations)
A,B
DW
H
S
Hub
Opening
3R, 6R
Meter
Socket
A
E,F,G
DW
H
C,D,E,F,G
S
D,E,F,G
4R, 5R
Meter
Socket
A
Hub
Opening
DW
H
D,E,F,G
S
7R
Meter
Socket
Offset
F,G,H
A
Hub
Opening DW
H
F,G,H
S
8R
Meter
Socket
F,G,H
A
A,B
A,B
Hub
Opening
DW
H
F,G,H
S
9R
Meter
Socket
F,G,H
A
A,B A,B
Hub
Opening
DW
H
F,G,H,I
S
10R
Meter
Socket
F,G,H,I
A
Hub
Opening
DW
H
F,G,H,I
S
11R
Meter
Socket
Offset
F,G,H,I
A
Hub
Opening
Hub
Opening
DW
H
G,H,I,J
12R
Meter
Socket
A,B
DW
Hub Opening
H
Main
Lugs
Meter
Socket
SA
C,D,E,F,G (13R)
F,G,H (17R)
C,D,E,F,G
(13R, 17R)
C,D,E,F,G
(13R, 17R)
13R and 17R
Hub Opening
Meter
Socket
DW
H
Main
Lugs
SA
C,D,E,F,G
13R1
C,D,E,F,G C,D,E,F,G
Hub Opening
Meter
Socket
DW
H
Main
Lugs
SA
C,D,E,F,G
(14R, 18R)
14R and 18R
C,D,E,F,G (14R)
F,G,H (18R)
C,D,E,F,G
(14R, 18R)
DW
H
Main
Lugs
SA
C,D,E,F,G
15R and 16R
Hub Opening
C,D,E,F,G C,D,E,F,G
Meter Socket
Left position omitted on
5-Gang unit (15R)
Meter Socket
Left position omitted on
5-Gang unit (19R)
DW
H
Main
Lugs
SA
C,D,E,F,G
(19R, 20R)
C,D,E,F,G
(19R, 20R)
19R and 20R
F,G,H
(19R, 20R)
Hub Opening
METERING EQUIPMENT
www.SquareD.com
For the most up-to-date information
42
Metering
MP METER-PAK™ Meter Centers
Class 4141
© 2004 Schneider Electric
All Rights Reserved
6/7/04
Ring and Ringless Type Devices
Consult local utility for approval before installation.
120/240 Vac 1 Phase 3 Wire.
Main lugs only—two to six meter sockets.
Enclosures are indoor/rainproof NEMA 3R construction.
Suitable only for use as service equipment.
Swingable mounting feet supplied at bottom of device.
Factory installed mechanical lugs, alternate lugs and NEMA/EUSERC lug landing kits available.
Surface mount, convertible to semi-flush with field installed flange kit.
Ring type devices supplied with 4-jaw meter sockets (5th jaw kits available, order separately).
Ringless type devices supplied with 5-jaw meter sockets, available with and without horn or lever bypass.
Provisions for mounting 2-pole circuit breaker for each meter socket position (order circuit breakers separately).
Mounting channel supplied, except for box 1R (125 A, 2-position).
Combination overhead/underground feed.
Step 1: Select Ring or Ringless Type MP METER-PAK Metering Equipment
aMeets EUSERC standards.
bMeets EUSERC standards with addition of lug landing kit, MMSK2.
cRequires use of EZM125QOA adapter (order separately). Refer to page 50 for pricing.
UL Listed short circuit current rating depends on lowest interrupting rating of circuit breaker installed. (See page 43)
Ring Type MP METER-PAK Metering Equipment with 125 A (42k RMS Symmetrical Amperes Maximum SCCR) or
200 A (22k RMS Symmetrical Amperes Maximum SCCR) Meter Socket Positions
Amps
per Pos.
No. of
Pos.
Factory Installed
Main Lug Ampacity
(See page 43 for
alternate lugs)
Main Bus
Ampacity
Catalog
NumberbPrice
Line Lug Wire
Size Al/Cu
AWG/kcmil
Circuit
Breaker Type
(2-Pole)
Hub Prov. Semi-Flush
Flange Kit Wt Lbs
Box
No.
(See
pg. 44)
125
2200 200 MP22125a$651. (1) 4–250
QO,
QO-VH,
QOH
A/B300 MPSF12 46 1R
3300 300 MP33125b791. (1) 1/0–600 or
(2) 1/0–250 A-L MPSF14 95 2R
4400 400 MP44125b1153. (1) 1/0–600 or
(2) 1/0–250 A-L MPSF14 97 2R
5400 Al
500 Cu 500 MP55125b1386. (1) 1/0–600 or
(2) 1/0–250 A-L MPSF16 130 3R
6400 Al
500 Cu 600 MP66125b1610. (1) 1/0–600 or
(2) 1/0–250 A-L MPSF16 132 3R
200
2400 400 MP42200b849. (1) 1/0–600 or
(2) 1/0–250
QOM2-MM,
QOM2-MVH A-L
MPSF23 99 4R
3400 400 MP43200b1434. (1) 1/0–600 or
(2) 1/0–250 MPSF23 99 4R
4400 600 MP64200b1876. (1) 1/0–600 or
(2) 1/0–250 MPSF24 135 5R
5600 Al, 750 Cu 800 MP85200b2251. (2) 3/0–500 MPSF26 173 6R
6600 Al, 750 Cu 800 MP86200b2693. (2) 3/0–500 MPSF26 173 6R
Ringless Type MP METER-PAK Metering Equipment with 125 A (42k RMS Symmetrical Amperes Maximum SCCR) or
200 A Type MPR, MPH (22k RMS Symmetrical Amperes Maximum SCCR) or
225 A Type MPL (100k RMS Symmetrical Amperes Maximum SCCR) Meter Socket Positions
Amps
Per
Pos.
No.
of Pos.
Factory Installed
Main Lugs
Ampacity
(See page 43 for
alternate lugs)
Main Bus
Ampacity
No. Bypass
Catalog
Number
Price
Horn
Bypass
Catalog
Number
Price
Lever
Bypass
Catalog
Number
Price
Line Lug
Wire Size
Al/Cu
AWG/kcmil
Circuit
Breaker
Type
(2-Pole)
Hub
Prov.
Semi-Flush
Flange Kit
Wt
Lbs
Box
No.
(See
pg.
44)
125
2200 200 MPR22125 $663. MPH22125 $668. . . . . . . . (1) 4–250
QO,
QO-VH,
QOH
A/B300 MPSF12 46 1R
3300 300 MPR33125 813. MPH33125 835. . . . . . . . (1) 1/0–600 or
(2) 1/0–250
A-L
MPSF14 95 2R
4400 400 MPR44125 1187. MPH44125 1220. . . . . . . . (1) 1/0–600 or
(2) 1/0–250 MPSF14 97 2R
5400 Al
500 Cu 500 MPR55125 1497. MPH55125 1553. . . . . . . . (1) 1/0–600 or
(2) 1/0–250 MPSF16 130 3R
6400 Al
500 Cu 600 MPR66125 1743. MPH66125 1810. . . . . . . . (1) 1/0–600 or
(2) 1/0–250 MPSF16 132 3R
200
2400 400 MPR42200 860. MPH42200 866.
. . . . . . . (1) 1/0–600 or
(2) 1/0–250
QOM2-MM,
QOM2-MVH
A-L
MPSF23 99 4R
3400 400 MPR43200 1457. MPH43200 1479. MPSF23 99 4R
4400 600 MPR64200 1910. MPH64200 1944. MPSF24 135 5R
225
2300 300 . . . . . . . . . . . . MPL32225 $1159.
(1) 1/0–600 or
(2) 1/0–250
QB, QD, QG, QJ,
QOe, QO-VHe
or QOHe
N/A 105 7R
3400 400 . . . . . . . . . . . . MPL53225 1827. N/A 147 8R
4400 600 . . . . . . . . . . . . MPL64225 2437. N/A 200 9R
200 5600 Al, 750 Cu 800 MPR85200 2363. MPH85200 2418. . . . . . . . (2) 3/0–500 QOM2-MM,
QOM2-MVH
MPSF26 173 6R
6600 Al, 750 Cu 800 MPR86200 2827. MPH86200 2894. . . . . . . . (2) 3/0–500 MPSF26 173 6R
DE4 Discount
Schedule
For additional information, reference Catalog #4100CT9801.
METERING EQUIPMENT
43
Metering
MP METER-PAK™ Meter Centers
Tenant Circuit Breakers & Accessories
© 2004 Schneider Electric
All Rights Reserved
6/7/04
www.SquareD.com
For the most up-to-date information
Step 2: Select Tenant Circuit Breakers
aOrder only. Not stocked in PDS. Order Point: Lincoln.
bRequires use of EZM125QOA adapter (order separately). Refer to page 50 for pricing.
cQOVH tenant circuit breakers are rated 22,000 AIR at 120/240 Vac.
dQOH tenant circuit breakers are rated 42,000 AIR at 120/240 Vac.
UL Listed Short Circuit Current Rating depends on lowest interrupting rating of circuit breaker installed.
(Refer to the table on the bottom of page 52 for Square D certified ratings for downstream panelboards and
load centers.)
Amps 10,000 AIR
120/240 Vac
Price
u
22,000 AIR
120/240 Vac
Price
u
42,000 AIR
120/240 Vac
Price
u
100,000 AIR
120/240 Vac
Price
u
For Use in 125 A Max. Type MP, MPR and MPH METER-PAK Metering Equipment
60 QO260 $44.70 QO260VH $97.00 QOH260a$211.00 . . . . . .
70 QO270 89.00 QO270VH 149.00 QOH270a352.00 . . . . . .
80 QO280 126.00 QO280VH 210.00 QOH280a434.00 . . . . . .
90 QO290 126.00 QO290VH 210.00 QOH290 434.00 . . . . . .
100 QO2100 126.00 QO2100VH 210.00 QOH2100 434.00 . . . . . .
125 QO2125 285.00 QO2125VH 689.00 QOH2125 926.00 . . . . . .
For Use in 200 A Max. Type MP, MPR and MPH METER-PAK Metering Equipment
100 QOM2100MM 316.00 QOM2100MVH 762.00 . . . . . . . . . . . .
125 QOM2125MM 316.00 QOM2125MVH 762.00 . . . . . . . . . . . .
150 QOM2150MM 316.00 QOM2150MVH 762.00 . . . . . . . . . . . .
175 QOM2175MM 316.00 QOM2175MVH 762.00 . . . . . . . . . . . .
200 QOM2200MM 316.00 QOM2200MVH 762.00 . . . . . . . . . . . .
For Use in 225 A MPL Lever Bypass METER-PAK Metering Equipment
10,000 AIR
120/240 Vac
Price
u
25,000 AIR
120/240 Vac
Price
u
65,000 AIR
120/240 Vac
Price
u
100,000 AIR
120/240 Vac
Price
u
40 QO240b44.70 QO240VHbc 97.00 QOH240bd 211.00 . . . . . .
50 QO250b44.70 QO250VHbc 97.00 QOH250bd 211.00 . . . . . .
60 QO260b44.70 QO260VHbc 97.00 QOH260bd 211.00 . . . . . .
70 QBP22070TM 316.00 QDP22070TM 762.00 QGP22070TM 1014.00 QJP22070TM $1260.00
80 QBP22080TM 316.00 QDP22080TM 762.00 QGP22080TM 1014.00 QJP22080TM 1260.00
90 QBP22090TM 316.00 QDP22090TM 762.00 QGP22090TM 1014.00 QJP22090TM 1260.00
100 QBP22100TM 316.00 QDP22100TM 762.00 QGP22100TM 1014.00 QJP22100TM 1260.00
110 QBP22110TM 316.00 QDP22110TM 762.00 QGP22110TM 1014.00 QJP22110TM 1260.00
125 QBP22125TM 316.00 QDP22125TM 762.00 QGP22125TM 1014.00 QJP22125TM 1260.00
150 QBP22150TM 316.00 QDP22150TM 762.00 QGP22150TM 1014.00 QJP22150TM 1260.00
175 QBP22175TM 316.00 QDP22175TM 762.00 QGP22175TM 1014.00 QJP22175TM 1260.00
200 QBP22200TM 316.00 QDP22200TM 762.00 QGP22200TM 1014.00 QJP22200TM 1260.00
225 QBP22225TM 316.00 QDP22225TM 762.00 QGP22225TM 1014.00 QJP22225TM 1260.00
QO2100VH
2-Pole, Plug-on Type
Circuit Breaker
QDP22200TM
2-Pole, Bolt-on Type
Circuit Breaker
QOM2200MVH
MMLK500
uDE2A DE4 Discount
Schedule
Accessories
Description Catalog
Number Price
Fifth Jaw Kit 5J $12.20
Horn Bypass Kit MMHB 11.10
QO Adapter for Bolt-on Q2M tenant circuit
breakers (40–125 A, 2-pole) EZM125QOA 182.00
Slider Type Manual Circuit Closing:
125 A Ring Style
2 Position Top Meter (Only) MM125MBe114.00
125 A/200 A Ring Style MM200MBe114.00
Sealing Rings:
Snap-on Aluminum 2920910001 5.00
Screw Type Aluminum 29008W 13.40
Snap-on Type Stainless Steel ARP00026 11.10
Meter Cover-Lexan®29007 6.70
Optional Lug Kits:
(1) 1/0–600 AWG/kcmil or
(2) 1/0–250 per phase MMLK250fg 100.00
(2) 3/0–500 AWG/kcmil per phase MMLK500g133.00
(2) 2–600 AWG/kcmil per phase MMLK600g155.00
Semiflush Kits:
125 A 2 Position MPSF12 67.00
125 A 3–4 Position MPSF14 89.00
125 A 5–6 Position MPSF16 145.00
200 A 2–3 Position MPSF23 96.00
200 A 4 Position MPSF24 114.00
200 A 5–6 Position MPSF26 170.00
For additional information, reference Catalog #4100CT9801.
eThe meter center short circuit current rating is 10,000 amperes RMS
symmetrical when manual circuit closing is used. Not rated for continuous
duty.
fStandard lug for 3 through 6 position 125 A and 2 through 4 position 200 A
devices.
gCannot be installed on 2 position 125 A device.
hOrder only. Not stocked in PDS. Order point: Lexington.
See page 40 for hubs and closing plates
NEMA/EUSERC Lug Landing Kit:
For 3 through 6 position 125 A and 200 A
devices. Each pad rated 600 A maximum
and includes (2) 1/2-13 studs and
mounting hardware.
MMSK2g$123.00
NEMA Lug Landing Kit:
For use ONLY on MPL43225 and
MPL64200 with optional lugs. See wiring
diagram of each device for optional lugs.
MMSK4 184.00
MP Meter-Pak Wireway:
125 A 2 Position ONLY MP43X8PED 294.00
125 A 3–6 Position MP43X11PED 336.00
200 A 2–6 Position MP43X11PED 336.00
MPL32-200 MP35X11PEDh336.00
MPL53-200 MP43X11PED 336.00
MPL64-200 MP35X11PEDh336.00
MP Meter-Pak Wireway Extensions:
Used ONLY with MP43X8PED MP12X8PEDEXTh68.00
Used with MP43X11PED &
MP35X11PED MP12X11PEDEXTh84.00
Accessories (Continued)
Description Catalog
Number Price
METERING EQUIPMENT
www.SquareD.com
For the most up-to-date information
44
Metering
MP METER-PAK™ Meter Centers
Dimensions, Knockouts
© 2004 Schneider Electric
All Rights Reserved
6/7/04
A Hub Opening Supplied
with ACP Closing Plate
18.50
470
37.50
953
12.28
312
9.00
229
7.28
185
A
D,F,G and A or
B300 Hub Provision
C,D,F
C,D,F
Mounting Holes
(4) Locations
(Supplied without
Mounting Channel)
Box 1R
7.28
185
C,D,F
E,F,G,H,I,J and
A-L Hub Provision
48.12
1222
24.34
618
9.00
229
Typ.
11.19
284
Top Position
Omitted on
3-Gang Unit
Box 2R
C,D,F
A-L Hub Opening Supplied
with ACPL Closing Plate
A,B
7.28
185
36.46
926
9.00
229
Typ.
C,D,F
Top Left
Position
Omitted on
5-Gang Unit
42.37
1076
11.19
284
C,D,F
A
Box 3R
A-L Hub Opening Supplied
with ACPL Closing Plate
A,B
E,F,G,H,I,J and
A-L Hub Provision
C,D,F
43.41
1103
9.00
229
Typ.
12.22
310
Top Position
Omitted on
2-Gang Unit
8.28
210
29.44
748
A-L Hub Opening Supplied
with ACPL Closing Plate
Box 4R
C,D,E,F
A,B
E,F,G,H,I,J and
A-L Hub Provision
C,D,F
52.00
1321
9.00
229
Typ.
12.22
310
Box 5R
29.44
748
8.28
210
A-L Hub Opening Supplied
with ACPL Closing Plate
C,D,E,F
A,B
E,F,G,H,I,J and
A-L Hub Provision
C,D,F
9.00
229
Typ.
43.41
1103
12.22
310
Top Left
Position
Omitted on
5-Gang Unit
46.68
1186
8.28
210
A-L Hub Opening Supplied
with ACPL Closing Plate
A,B,C
C,D,E,F
E,F,G,H,I,J and A-L Hub Provision
Box 6R
C,D,E,F
A-L Hub Opening Supplied
with ACPL Closing Plate
60.25
1530
14.00
356
34.00
864
Box 7R
9.62
244
19.43
494
E,F,G,H,I,J and
A-L Hub Provision
C,D,E,F
A,B
C,D,E,F
53.12
1349
14.00
356
Typ.
13.43
341
Box 8R
35.37
898
A-L Hub Opening Supplied
with ACPL Closing Plate
9.62
244
E,F,G,H,I,J and
A-L Hub Provision
C,D,E,F
A,B
C,D,E,F
67.37
1711
14.00
356
Typ.
13.43
341
Box 9R
35.37
898
A-L Hub Opening Supplied
with ACPL Closing Plate
9.62
244
E,F,G,H,I,J and
A-L Hub Provision
C,D,E,F
A,B
Knockouts
Symbol ABCDEFGH I J
Conduit Size
(inches) 123411
1411222
1233
124
METERING EQUIPMENT
45
Metering
EZ METER-PAK® Meter Centers
Single Phase—Indoor/Rainproof
© 2004 Schneider Electric
All Rights Reserved
6/7/04
www.SquareD.com
For the most up-to-date information
Main Devices—NEMA 3R Construction
aFor mechanical lugs (3/0 to 600 kcmil) order kit catalog number CMELK4, Price $91.00. Kit includes 4 lugs only.
Multiple kits may be required, consult factory. For crimp-type lugs refer to Anderson Electrical Connector Products
Catalog AEC-40R.
bHas a 100,000 RMS symmetrical ampere short circuit current rating.
cHas a maximum 100,000 RMS symmetrical short circuit current rating when protected by Class R (600 A Max.) or
Class T (800 A Max.) fuses. For other short circuit current ratings refer to table on page 53. Suitable for use on LINE
or LOAD side of service equipment. Use to feed type EZMT branch units for 6-Sub Division Rule applications.
dDoes not meet EUSERC Standards. Not stocked in PDS, Order only (allow 6 weeks for delivery). Not UL Listed.
eAvailable by special order with main circuit breaker supplied with other standard ampere ratings, consult local Field
Office (allow 6 weeks for delivery).
fAmpere rating of the PA circuit breaker supplied with this main can be changed it field by ordering a different set of
rating columns, refer to Digest 173 page 6-25 for listing.
gSupplied with copper horizontal bus bars and aluminum vertical bus bars.
hMay be end mounted to feed branch units with 800 A or 1200 A horizontal cross bus.
Overhead/Underground Feed
System
Type
Ampere
Rating
Horizontal
Cross Bus
Rating
and Bus Bar
Material
Catalog Number
Width
(Dim.
see
pg. 51)
Price
Line Side
Lug and Wire Size
(AWG–kcmil)
Conductor Qty.
per Phase and
Neutral
(Factory Installed)
65,000 RMS Symmetrical Ampere Short Circuit Current Rating
Main Circuit Breakers (1Ø Incoming and 1Ø Outgoing)
1Ø3W
120/240 Vac
400 800 A Al EZM1400CBe18.66 $4120. (1) #1–600 or (2) #1–250
600 800 A Al EZM1600CBe18.66 5715. (3) 3/0–500
800 800 A Al EZM1800CBe18.66 7576. (3) 3/0–500
1000 1000 A Al EZM11000CBeh 18.66 10511. (3) 3/0–500
1200 1200 A Al/Cu EZM11200CBfg 30.19 13577. (4) 1/0–750
1600 1200 A Al/Cu EZM11600CBfg 30.19 19936. (6) 1/0–750
100,000 RMS Symmetrical Ampere Short Circuit Current Rating
Main Fusible Switches (1Ø Incoming and 1Ø Outgoing)—
Requires 300 Vac Class T Fuses (Order Separately)
1Ø3W
120/240 Vac
400 800 A Al EZM1400FS 18.66 2659. (1) #1–600 or (2) #1–250
600 800 A Al EZM1600FS 18.66 4652. (3) 3/0–500
800 800 A Al EZM1800FS 18.66 5981. (3) 3/0–500
1200 1200 A Al/Cu EZM11200FSg30.19 7709. (4) 1/0–750
Main Lugs Terminal Boxes (1Ø Incoming and 1Ø Outgoing)c
1Ø3W
120/240 Vac
225 800 A Al EZM1225TB 11.50 532. (1) 4–300
225 800A Cu EZM1225TBCU 11.50 581. (1) 4–300
400 800 A Al EZM1400TB 18.66 610. (2) 3/0–500
400 800A Cu EZM1400TBCU 18.66 677. (2) 3/0–500
600 800 A Al EZM1600TB 17.00 665. (1) 350–750 or (2) 1/0–300
600 800A Cu EZM1600TBCU 17.00 810. (1) 350–750 or (2) 1/0–300
800 800 A Al EZM1800TB 23.93 824. (4) 3/0–500
800 800A Cu EZM1800TBCU 23.93 1105. (4) 3/0–500
1600 1200 A Al EZM11600TBg22.33 2392. (6) 3/0–600
1600 1200 A Cu EZM11600TBCU 22.33 2986. (6) 3/0–600
Underground Feed Only
System
Type
Ampere
Rating
Horizontal
Cross Bus
Rating
and Bus Bar
Material
Catalog Number
Meets EUSERC
Requirements
Width
(Dim.
see
pg. 51)
Price
Factory Installed
Lug Landings
For Use with
Crimp-Type Lugs
(2-Hole Mounting)
Qty. per Phase
and Neutrala
65,000 RMS Symmetrical Ampere Short Circuit Current Rating
Main Circuit Breakers (1Ø Incoming and 1Ø Outgoing)
1Ø3W
120/240 Vac
400 800 A Al EZM1400CBUe20.46 $4253. 1 (Order Lugs Separately)
600 800 A Al EZM1600CBUe20.46 6114. 2 (Order Lugs Separately)
800 800 A Al EZM1800CBUe20.46 7841. 2 (Order Lugs Separately)
1000 1000 A Al EZM11000CBUebh 34.19 11031. 3 (Order Lugs Separately)
1200 1200 A Al/Cu EZM11200CBUegb 34.19 14221. 3 (Order Lugs Separately)
1600 1200 A Al/Cu EZM11600CBUfgd 30.19 21105. 6 (Order Lugs Separately)
100,000 RMS Symmetrical Ampere Short Circuit Current Rating
Main Circuit Breakers (1Ø Incoming and 1Ø Outgoing)
1Ø3W
120/240 Vac
1000 1000 A Al EZM11000CBUeh 34.19 11031. 3 (Order Lugs Separately)
1200 1200 A Al/Cu EZM11200CBUeg 34.19 14221. 3 (Order Lugs Separately)
100,000 RMS Symmetrical Ampere Short Circuit Current Rating
Main Fusible Switches (1Ø Incoming and 1Ø Outgoing)—
Requires 300 Vac Class T Fuses (Order Separately)
1Ø3W
120/240 Vac
400 800 A Al EZM1400FSU 20.46 4120. 1 (Order Lugs Separately)
600 800 A Al EZM1600FSU 20.46 6246. 2 (Order Lugs Separately)
800 800 A Al EZM1800FSU 20.46 7709. 2 (Order Lugs Separately)
1200 1200 A Al/Cu EZM11200FSUg34.19 9436. 3 (Order Lugs Separately)
Main Lugs Terminal Boxes (1Ø Incoming and 1Ø Outgoing). Supplied with isolated neutral (can not be bonded).
c
1Ø3W
120/240 Vac
400 800 A Al EZM1400TBU 16.16 1029. 1 (Order Lugs Separately)
400 800A Cu EZM1400TBUCU 16.16 1379. 1 (Order Lugs Separately)
800 800 A Al EZM1800TBU 24.16 1218. 2 (Order Lugs Separately)
800 800A Cu EZM1800TBUCU 24.16 1633. 2 (Order Lugs Separately)
1200 1200 A Al/Cu EZM11200TBUg32.16 2483. 3 (Order Lugs Separately)
1200 1200 A Cu EZM11200TBUCU 32.16 3327. 3 (Order Lugs Separately)
EZM1800CB
EZM1800CBU
For additional information, reference Catalog #4100CT9801.
DE4 Discount
Schedule
1Ø3W EZ METER-PAK Meter Centers—
UL Listed
Select EZM meter center short circuit current rating RMS
symmetrical amperes from table on page 53. Using
this table as a reference, make the following
selections:
Select EZM single phase main device below with an
equal or higher short circuit rating than the application.
Select EZM single phase branch units; page 46.
Select proper 2-pole type QO, QO-VH, QOH,
QBP-TM, QDP-TM, QGP-TM or QJP-TM branch
circuit breakers for use as tenant mains in branch unit;
page 50.
Select accessories as required; page 50.
Dimensions; page 51.
METERING EQUIPMENT
www.SquareD.com
For the most up-to-date information
46
Metering
EZ METER-PAK® Meter Centers
Single Phase—Indoor/Rainproof
© 2004 Schneider Electric
All Rights Reserved
6/7/04
1Ø3W EZ Meter-Pak Meter Centers — UL Listed
Branch Devices—NEMA 3R Construction
aSnap-on aluminum sealing rings supplied as standard.
bSupplied with removable drip hood and equipped with an indoor top endwall with knockouts provided.
cSupplied with bondable neutral, suitable for use as service equipment. Use main lugs tapbox type EZM-TBU for 6-Sub Division Rule applications to feed this
device. Supplied with copper horizontal bus bars and aluminum vertical bus bars.
dDevice has limited short circuit current rating, refer to page 53.
eSupplied with Class 320 meter socket.
fFor 1200A main cross bus add suffix “X” to catalog number (Example: EZM314125X). Add $147. per device. Allow 6 weeks for delivery.
gDoes not meet EUSERC 48" minImum / 75" maximum meter height requirements for outdoor installations.
This device measures 37" minimum / 75" maximum. EUSERC indoor requirements are 36" minimum / 75" maximum.
hNot UL Listed.
iType QO, QO-VH and QOH branch circuit breakers (40 A–60 A) may be installed with use of EZM125QOA adapter kits, refer to page 50.
Branch Units—1Ø Incoming and 1Ø Outgoing
System
Type
Width
(Dim.
see pg.
51)
Number
of
Meter
Sockets
Horizontal
Cross Bus
Rating
and Bus Bar
Material
Ring Type
4-Jaw Meter Socketa
Ringless Type
5-Jaw Meter Socket
Ringless Type
5-Jaw Meter Socket
with Horn Bypass
Catalog
Number Price Catalog
Number Price Catalog
Number Price
125 A Maximum (Order Type QO, QO-VH or QOH Circuit Breakers Separately)f
1Ø3W
120/240 Vac
2-Pole Branch
Circuit Breakers
12.25
3800 A Al EZM113125 $957. EZMR113125 $957. EZMH113125 $1170.
800 A Cu EZM113125CU 1288. EZMR113125CU 1288. EZMH113125CU 1608.
4800 A Al EZM114125 1276. EZMR114125 1276. EZMH114125 1435.
800 A Cu EZM114125CU 1767. EZMR114125CU 1767. EZMH114125CU 2007.
5800 A Al EZM115125 1569. EZMR115125 1569. EZMH115125 1940.
800 A Cu EZM115125CU 2206. EZMR115125CU 2206. EZMH115125CU 2764.
6800 A Al EZM116125 1861. EZMR116125 1861. EZMH116125 2366.
800 A Cu EZM116125CU 2644. EZMR116125CU 2644. EZMH116125CU 3402.
225 A Maximum Branch Units (Order Type QB, QD, QG or QJ Circuit Breakers Separately)fi
1Ø3W
120/240 Vac
2-Pole Branch
Circuit Breakers
17.38
2800 A Al EZM112225 1515. EZMR112225 1515. EZMH112225 1649.
800 A Cu EZM112225CU 2126. EZMR112225CU 2126. EZMH112225CU 2326.
3800 A Al EZM113225 1861. EZMR113225 1861. EZMH113225 2046.
800 A Cu EZM113225CU 2644. EZMR113225CU 2644. EZMH113225CU 2923.
4800 A Al EZM114225 2392. EZMR114225 2392. EZMH114225 2685.
800 A Cu EZM114225CU 3441. EZMR114225CU 3441. EZMH114225CU 3881.
51200 A Al/CU EZM115225 3143. EZMR115225 3143. EZMH115225 3143.
1200 A Cu EZM115225CU 4459. EZMR115225CU 4459. EZMH115225CU 5198.
225 A Maximum Commercial Branch Units
(Order Type QB, QD, QG or QJ Circuit Breakers Separately)i
System
Type
Number
of Meter
Sockets
Horizontal
Cross Bus
Rating
and Bus Bar
Material
Ringless Type 5-Jaw Meter Socket
with Lever Bypass and Jaw Releasee
Ring Type 5-Jaw Meter Socket
with Test Block Bypass.
Meets EUSERC Requirements
Catalog
Number
Width
(Dim.
see pg.
51)
Price Catalog
Number
Width
(Dim.
see pg.
51)
Price
1Ø3W
120/240 Vac
2-Pole Branch
Circuit Breakers
1
1200 A Al/Cu EZML111225
19.44
$1635. EZMT111225c22.42 $2258.
1200 A Cu EZML111225CU 2453. . . . . . . . . .
1200 A Al/Cu EZML111225Db1717. . . . . . . . . .
2
1200 A Al/Cu EZML112225
19.44
2977. EZMT112225c22.42 4095.
1200 A Cu EZML112225CU 4466. . . . . . . . . .
1200 A Al/Cu EZML112225Db3126. . . . . . . . . .
3
1200 A Al/Cu EZML113225
19.44
4386. EZMT113225cg 22.42 6143.
1200 A Cu EZML113225CU 6579. . . . . . . . . .
1200 A Al/Cu EZML113225Db4605. . . . . . . . . .
4
1200 A Al/Cu EZML114225
19.44
5875. . . . . . . . . .
1200 A Cu EZML114225CU 8813. . . . . . . . . .
1200 A Al/Cu EZML114225Db6169. . . . . . . . . .
400 A Maximum Commercial Branch Units
System
Type
Number
of Meter
Sockets
Main
Cross Bus
Rating
and Bus Bar
Material
Ringless Type 5-Jaw Meter Socket
with Lever Bypass and Jaw Release—
400 A Type LAL Branch Circuit Breaker
Included Factory Installed.deh
Ringless Type K Bolt-On
4-Jaw Meter Socket with Manual Bypass—
400A Type DJM Branch Circuit Breaker
Included Factory Installed. Ampere rating
field adjustable from 160 A–400 A.
Catalog Number
Width
(Dim.
see pg.
51)
Price Catalog Number
Width
(Dim.
see pg.
51)
Price
1Ø3W
120/240 Vac
2-Pole Branch
Circuit Breakers
11200 A Al/Cu EZML111400 23.21 $3987. . . . . . . . . .
1200 A Cu EZML111400CU 5981. EZMK111400 27.56 $4949.
21200 A Al/Cu EZML112400 23.21 7975. . . . . . . . . .
1200 A Cu EZML112400CU 11963. EZMK112400 27.56 9687.
EZMH114125
EZMT111225
EZML113225
For additional information, reference Catalog #4100CT9801.
DE4 Discount
Schedule
METERING EQUIPMENT
47
Metering
EZ METER-PAK® Meter Centers
Three Phase—Indoor/Rainproof
© 2004 Schneider Electric
All Rights Reserved
6/7/04
www.SquareD.com
For the most up-to-date information
Main Devices—NEMA 3R Construction
aFor mechanical lugs (3/0 to 600 kcmil) order kit catalog number CMELK4, Price $91.00. Kit includes 4 lugs only.
Multiple kits may be required, consult factory. For crimp-type lugs refer to Anderson Electrical Connector Products
Catalog AEC-40R.
bHas a 100,000 RMS symmetrical ampere short circuit current rating.
cHas a maximum 100,000 RMS symmetrical short circuit current rating when protected by Class R (600 A Max.) or
Class T (800 A Max.) fuses. For other short circuit current ratings refer to table on page 53. Suitable for use on LINE
or LOAD side of service equipment. Use to feed type EZMT branch units for 6-Sub Division Rule applications.
dDoes not meet EUSERC requirements. Not stocked in PDS, order only (allow 6 weeks for delivery). Not UL Listed.
eAvailable by special order with main circuit breaker supplied with other standard ampere ratings, consult your nearest
Square D/Schneider Electric sales office (allow 6 weeks for delivery).
fAmpere rating of the PA circuit breaker supplied with this main can be changed it field by ordering a different set of
rating columns, refer to Digest 173 page 6-25 for listing.
gSupplied with copper horizontal bus bars and aluminum vertical bus bars.
hMay be end mounted to feed branch units with 800 A or 1200 A horizontal cross bus.
Overhead/Underground Feed
System
Type
Ampere
Rating
Horizontal
Cross Bus
Rating
and Bus Bar
Material
Catalog
Number
Width
(Dim.
see
pg.
51)
Price
Line Side
Lug and Wire Size
(AWG–kcmil)
Conductor Qty.
per Phase
and Neutral
(Factory Installed)
65,000 RMS Symmetrical Ampere Short Circuit Current Rating
Main Circuit Breakers (3Ø Incoming and 3Ø Outgoing)
3Ø4W
208Y/120 Vac
OR
240/120 Vac
DELTA
400 800 A Al EZM3400CBe18.66 $4413. (1) #1–600 or (2) #1–250
600 800 A Al EZM3600CBe18.66 6831. (3) 3/0–500
800 800 A Al EZM3800CBe18.66 9100. (3) 3/0–500
1000 1000 A Al EZM31000CBei 18.66 11351. (3) 3/0–500
1200 1200 A Al/Cu EZM31200CBfg 30.19 15418. (4) 1/0–750
1600 1200 A Al/Cu EZM31600CBfg 30.19 23525. (6) 1/0–750
100,000 RMS Symmetrical Ampere Short Circuit Current Rating
Main Fusible Switches (3Ø Incoming and 3Ø Outgoing)—
Requires 300 Vac Class T Fuses (Order Separately)
3Ø4W
208Y/120 Vac
OR
240/120 Vac
DELTA
400 800 A Al EZM3400FS 18.66 2977. (1) #1–600 or (2 )#1–250
600 800 A Al EZM3600FS 18.66 5582. (3) 3/0–500
800 800 A Al EZM3800FS 18.66 7710. (3) 3/0–500
Main Lugs Terminal Boxes (3Ø Incoming and 3Ø Outgoing)c
3Ø4W
208Y/120 Vac
OR
240/120 Vac
DELTA
225 800 A Al EZM3225TB 11.50 675. (1) 4–300
225 800A Cu EZM3225TBCU 11.50 749. (1) 4–300
400 800 A Al EZM3400TB 18.66 742. (2) 3/0–500
400 800A Cu EZM3400TBCU 18.66 1286. (2) 3/0–500
600 800 A Al EZM3600TB 17.00 797. (1) 350–750 or (2) 1/0–300
600 800A Cu EZM3600TBCU 17.00 1415. (1) 350–750 or (2) 1/0–300
800 800 A Al EZM3800TB 23.93 961. (4) 3/0–500
800 800A Cu EZM3800TBCU 23.93 2363. (4) 3/0–500
1600 1200 A Al EZM31600TBg22.33 2685. (6) 3/0–600
1600 1200 A Cu EZM31600TBCU 22.33 3576. (6) 3/0–600
Underground Feed Only
System Type Ampere
Rating
Horizontal
Cross Bus
Rating
and Bus Bar
Material
Catalog Number
Meets EUSERC
Requirements
Width
(Dim.
see
pg.
51)
Price
Factory Installed
Lug Landings
For Use with
Crimp-Type Lugs
(2-Hole Mounting)
Qty. per Phase
and Neutrala
65,000 RMS Symmetrical Ampere Short Circuit Current Rating
Main Circuit Breakers (3Ø Incoming and 3Ø Outgoing)
3Ø4W
208Y/120 Vac
OR
240/120 Vac
DELTA
400 800 A Al EZM3400CBUe20.46 $4785. 1 (Order Lugs Separately)
600 800 A Al EZM3600CBUe20.46 7204. 2 (Order Lugs Separately)
800 800 A Al EZM3800CBUe20.46 9410. 2 (Order Lugs Separately)
1000 1000 A Al EZM31000CBUebi 34.19 11962. 3 (Order Lugs Separately)
1200 1200 A Al/Cu EZM31200CBUegb 34.19 16215. 3 (Order Lugs Separately)
1600 1200 A Al/Cu EZM31600CBUfgd 30.19 24780. 6 (Order Lugs Separately)
100,000 RMS Symmetrical Ampere Short Circuit Current Rating
Main Circuit Breakers (3Ø Incoming and 3Ø Outgoing)
3Ø4W,
208Y/120 Vac
OR
240/120 Vac
DELTA
1000 1000 A Al EZM31000CBUei 34.19 11962. 3 (Order Lugs Separately)
1200 1200 A Al/Cu EZM31200CBUeg 34.19 16215. 3 (Order Lugs Separately)
Main Fusible Switches (3Ø Incoming and 3Ø Outgoing)—
Requires 300 Vac Class T Fuses (Order Separately)
3Ø4W
208Y/120 Vac
OR
240/120 Vac
DELTA
400 800 A Al EZM3400FSU 20.46 4652. 1 (Order Lugs Separately)
600 800 A Al EZM3600FSU 20.46 7576. 2 (Order Lugs Separately)
800 800 A Al EZM3800FSU 20.46 10101. 2 (Order Lugs Separately)
Main Lugs Terminal Boxes (3Ø Incoming and 3Ø Outgoing). Supplied with isolated neutral (can not be bonded).
c
3Ø4W
208Y/120 Vac
OR
240/120 Vac
DELTA
400 800 A Al EZM3400TBU 16.16 1225. 1 (Order Lugs Separately)
400 800 A Cu EZM3400TBUCU 16.16 1642. 1 (Order Lugs Separately)
800 800 A Al EZM3800TBU 24.16 1400. 2 (Order Lugs Separately)
800 800 A Cu EZM3800TBUCU 24.16 1875. 2 (Order Lugs Separately)
1200 1200 A Al/Cu EZM31200TBUg32.16 2975. 3 (Order Lugs Separately)
1200 1200 A Cu EZM31200TBUCU 32.16 3986. 3 (Order Lugs Separately)
For additional information,
reference Catalog #4100CT9801.
DE4 Discount
Schedule
3Ø4W EZ METER-PAK Meter Centers—
UL Listed
Select EZM meter center short circuit current rating RMS
symmetrical amperes from table on page 53. Using this
table as a reference, make the following selections:
Select three phase EZM main device below with an
equal or higher short circuit rating than the application.
Select EZM three phase branch units from
page 48 and 49.
Select proper 2-pole type QO, QO-VH, QOH,
QBP-TM, QDP-TM, QGP-TM or QJP-TM
or 3-pole QBP-TM, QDP-TM, QGP-TM or QJP-TM
branch circuit breakers for use as tenant mains in
branch unit; page 50.
Select accessories as required, page 50.
Dimensions, page 51.
EZM3600FS
EZM31600CB
METERING EQUIPMENT
www.SquareD.com
For the most up-to-date information
48
Metering
EZ METER-PAK® Meter Centers
Three Phase—Indoor/Rainproof
© 2004 Schneider Electric
All Rights Reserved
6/7/04
3Ø4W EZ Meter-Pak Meter Centers — UL Listed
Branch Devices—NEMA 3R Construction
aSnap-On aluminum sealing rings supplied as standard.
bDistance between meter sockets as measured from centerline to centerline is 10 inches.
cFor 240/120 Vac DELTA Systems add Suffix “CA” to catalog number (Example: EZM314125CA). All meter sockets are phased A and C only. Price remains
the same as the base catalog number. Order only branch units, not stocked in PDS (6-week delivery).
dSupplied with removable drip hood and equipped with an indoor top endwall with knockouts provided.
eSupplied with bondable neutral, suitable for use as service equipment. Use main lugs tap box type EZM-TBU for 6-Sub Division Rule applications to feed this
device. Supplied with copper horizontal bus bars and aluminum vertical bus bars.
fSupplied with Class 320 meter socket.
gFor 1200 A main cross bus, add suffix “X” to catalog number. Example: EZMR313125X. Add $147. per device. Allow 6 weeks for delivery.
hDoes not meet EUSERC 48" minimum/75" maximum meter height requirements as measured from grade level to centerline on meter. This device measures
37" minimum/75" maximum
iType QO, QO-VH and QOH branch circuit breakers (40 A–60 A) may be installed with use of EZM125QOA adapter kits, refer to page 50.
For 400 A maximum Commercial Branch Units, see page 49.
Branch Units—3Ø Incoming and 1Ø Outgoing
System
Type
Width
(Dim.
see pg.
51)
Number
of
Meter
Sockets
Horizontal
Cross Bus
Ratingg
and Bus Bar
Material
Ring Type
5-Jaw Meter Socketa
Ringless Type
5-Jaw Meter Socket
Ringless Type
5-Jaw Meter Socket
with Horn Bypass
Catalog
Number Price Catalog
Number Price Catalog
Number Price
125 A Maximum (Order Type QO, QO-VH or QOH Circuit Breakers Separately)agd
3Ø4W
208Y/120 Vac
5-Jaw-Meter Socket
2-Pole Branch
Circuit Breakers
12.25
3
800 A Al EZM313125 $1036. EZMR313125 $1036. EZMH313125 $1250.
800 A Cu EZM313125M10b2835. . . . . . . . . . . . .
800 A Cu EZM313125CU 1408. EZMR313125CU 1408. EZMH313125CU 1727.
4
800 A Al EZM314125 1356. EZMR314125 1359. EZMH314125 1649.
800 A Cu EZM314125M10b3780. . . . . . . . . . . . .
800 A Cu EZM314125CU 1887. EZMR314125CU 1891. EZMH314125CU 2326.
5
800 A Al EZM315125 1728. EZMR315125 1728. EZMH315125 2074.
800 A Cu EZM315125M10b4725. . . . . . . . . . . . .
800 A Cu EZM315125CU 2445. EZMR315125CU 2445. EZMH315125CU 2964.
6800 A Al EZM316125 1994. EZMR316125 1994. EZMH316125 2525.
800 A Cu EZM316125CU 2844. EZMR316125CU 2844. EZMH316125CU 3641.
225 A Maximum (Order Type QB, QD, QG or QJ Circuit Breakers Separately)aig
3Ø4W
208Y/120 Vac
5-Jaw-Meter Socket
2-Pole Branch
Circuit Breakers
17.38
2800 A Al EZM312225 $1515. EZMR312225 $1515. EZMH312225 $1649.
800 A Cu EZM312225CU 2126. EZMR312225CU 2126. EZMH312225CU 2326.
3800 A Al EZM313225 1861. EZMR313225 1861. EZMH313225 2074.
800 A Cu EZM313225CU 2644. EZMR313225CU 2644. EZMH313225CU 2964.
4800 A Al EZM314225 2499. EZMR314225 2499. EZMH314225 2765.
800 A Cu EZM314225CU 3602. EZMR314225CU 3602. EZMH314225CU 4001.
51200 A Al/Cu EZM315225 3280. EZMR315225 3638. EZMH315225 3812.
1200 A Cu EZM315225CU 4660. EZMR315225CU 4832. EZMH315225CU 5128.
225 A Maximum Commercial Branch Units
System
Type
Number of
MeterSockets
Horizontal
Cross Bus
Rating
and Bus Bar
Material
Ringless Type
Meter Socket
without Bypass
Ringless Type Meter Socket
with Lever Bypass
and Jaw Released
Ring Type Meter Socket
with Test Block Bypass.
Meets EUSERC
Requirements
Catalog
Number
Width
(Dim.
see
pg.
51)
Price Catalog
Number
Width
(Dim.
see
pg.
51)
Price Catalog
Number
Width
(Dim.
see
pg.
51)
Price
3Ø Incoming and 1Ø Outgoinga
(Order Type QB, QD, QG or QJ circuit breakers separately)i
3Ø4W
208Y/120 Vac
5-Jaw
Meter Sockets
2-Pole
Branch
Circuit
Breakers
11200 A Al/Cu . . . . . . . . . . . . . . . . . . EZMT311225b22.42 $2363.
2
1200 A Al/Cu . . . . . . . . . EZML312225
19.44
$2844. EZMT312225b22.42 4463.
1200 A Cu . . . . . . . . . EZML312225CU 4267. . . . . . . . . .
1200 A Al/Cu . . . . . . . . . EZML312225Dd2986. . . . . . . . . .
3
1200 A Al/Cu . . . . . . . . . EZML313225
19.44
4280. EZMT313225bh 22.42 6694.
1200 A Cu . . . . . . . . . EZML313225CU 6420. . . . . . . . . .
1200 A Al/Cu . . . . . . . . . EZML313225Dd4494. . . . . . . . . .
4
1200 A Al/Cu . . . . . . . . . EZML314225
19.44
5821. . . .
. . .
. . .
1200 A Cu . . . . . . . . . EZML314225CU 8732. . . . . . .
1200 A Al/Cu . . . . . . . . . EZML314225Dd6112. . . . . . .
3Ø Incoming and 3Ø Outgoing (Order QB, QD, QG or QJ circuit breakers separately)
3Ø4W
240/120 Vac
DELTA
or
208Y/120 Vac
7-Jaw
Meter Socket
3-Pole
Branch
Circuit
Breakers
1
1200 A Al/Cu . . . . . . . . . EZML331225
19.44
1861. EZMT331225b22.42 2625.
1200 A Cu . . . . . . . . . EZML331225CU 2791. . . . . . . . . .
1200 A Al/Cu . . . . . . . . . EZML331225Dd1954. . . . . . . . . .
2
1200 A Al/Cu EZMR332225
19.44
$3124. EZML332225
19.44
3403. EZMT332225b22.42 4638.
1200 A Cu EZMR332225CU 4686. EZML332225CU 5105. . . . . . . . . .
1200 A Al/Cu . . . . . . EZML332225Dd3573. . . . . . . . . .
3
1200 A Al/Cu EZMR333225
19.44
4891. EZML333225
19.44
5196. EZMT333225bh 22.42 6869.
1200 A Cu EZMR333225CU 7336. EZML333225CU 7795. . . . . . . . . .
1200 A Al/Cu . . . . . . EZML333225Dd5456. . . . . . . . . .
4
1200 A Al/Cu EZMR334225
19.44
6779. EZML334225
19.44
7111. . . .
. . .
. . .
1200 A Cu EZMR334225CU 10168. EZML334225CU 10666. . . . . . .
1200 A Al/Cu . . . . . . EZML334225Dd7476. . . . . . .
EZML313225
EZMT311225
EZMT311225
Without Cover
For additional information, reference Catalog #4100CT9801.
DE4 Discount
Schedule
METERING EQUIPMENT
49
Metering
EZ METER-PAK® Meter Centers
Three Phase—Indoor/Rainproof
© 2004 Schneider Electric
All Rights Reserved
6/7/04
www.SquareD.com
For the most up-to-date information
3Ø4W EZ Meter-Pak Meter Centers — UL Listed
Branch Devices—NEMA 3R Construction (Continued)
aFor 240/120 Vac DELTA Systems add Suffix “CA” to catalog number (Example: EZML312400CA). All meter sockets are phased A and C only. Price remains
the same as the base catalog number. “Order only” branch units, not stocked in PDS (4–6 week delivery). Order point Lexington.
bSupplied with copper horizontal bus bars and aluminum vertical bus bars.
cDevice has limited short circuit current rating, refer to page 53.
dSupplied with Class 320 meter socket.
EZM Main with Busway Tap
EZ METER-PAK metering equipment is available for use in high rise applications for connection to 800 A–5000 A I-LINE®
or I-LINE II plug-in busway installed as a vertical riser. Three phase only EZM main devices in the form of a main circuit
breaker or main fusible switch are available with an integral busway tap extending from the right or left side of the main
device and phased to align with the busway for either neutral front or neutral back installations.
BUSWAY Mains, three phase only (Indoor only) ordering instructions:
Step #1: Determine height to center line of busway plug-in opening, check local utility requirements for minimum and
maximum meter socket heights.
Step #2: Determine side of EZM main section for busway tap to extend from (busway tap is an integral part of the main
and extends to the left or right on the EZM device as viewed from the front).
Step #3: Check phasing of busway riser to insure that it matches phasing of busway tap on main section (indicated as
neutral front or neutral back as viewed from the front).
Step #4: Select catalog number from tables below.
Step #5: Busway main devices are build to order specials and require 4 to 6 weeks for delivery (order point Lexington).
eHas a maximum 65,000 RMS symmetrical short circuit current rating.
fHas a 100,000 RMS symmetrical ampere short circuit current rating.
gSupplied with copper horizontal bus bars and aluminum vertical bus bars.
hRequires use of branch units supplied with 1200 A horizontal cross bus.
iMay be end mounted to feed branch units with 800 A or 1200 A horizontal cross bus.
Note: Dimensions shown will position the centerline of top meter socket of a 125 A, 5-Gang or 6-Gang branch unit at 72" above floor level. Check with utility to
meet local requirements.
400 A Maximum Commercial Branch Units
System
Type
Number
of Meter
Sockets
Horizontal
Cross Bus
Rating
Ringless Type Meter Socket with Lever Bypass
and Jaw Release—
400 A Type LAL Branch Circuit Breaker
Included Factory Installed.cd
Ringless Type K Bolt-On Meter Socket with
Manual Bypass—
400 A Type DJM Branch Circuit Breaker
Included Factory Installed. Ampere rating
field adjustable from 160 A–400 A.
Catalog Number
Width
(Dim.
see pg.
51)
Price Catalog Number
Width
(Dim.
see pg.
51)
Price
3Ø Incoming and 1Ø Outgoinga
3Ø4W
208Y/120 Vac
5-Jaw Meter Socket
2-Pole Branch
Circuit Breakers
11200 A Al/Cu EZML311400b23.21 $3987. . . . . . . . . .
1200 A Cu EZML311400CU 5981. EZMK311400 27.56 $5949.
21200 A Cu EZML312400b23.21 7975. . . . . . . . . .
EZML312400CU 11963. EZMK312400 27.56 11689.
3Ø Incoming and 3Ø Outgoing
3Ø4W
240/120 Vac DELTA
or 208Y/120 Vac
7-Jaw Meter Socket
3-Pole Branch
Circuit Breakers
11200 A Al/Cu EZML331400b23.21 4652. . . . . . . . . .
1200 A Cu EZML331400CU 6977. EZMK331400 27.56 $7010.
21200 A Al/Cu EZML332400b23.21 9304. . . . . . . . . .
1200 A Cu EZML332400CU 13957. EZMK332400 27.56 13810.
EZM Mains with Busway Tap (Three Phase Only—note positioning left or right below)
Ampere
Rating
Width
(IN)
Horizontal
Cross Bus
Rating
Main Circuit Breaker with Busway TapeMain Fusible Switch with Busway Tapf
Neutral Front Neutral Back Price Neutral Front Neutral Back Price
Busway to RIGHT of metering equipment lineup
400 18.66 800 A Al EZM3400CBNFBTR EZM3400CBNBBTR $5924. EZM3400FSNFBTR EZM3400FSNBBTR $4488.
600 18.66 800 A Al EZM3600CBNFBTR EZM3600CBNBBTR 8342. EZM3600FSNFBTR EZM3600FSNBBTR 7093.
800 18.66 800 A Al EZM3800CBNFBTR EZM3800CBNBBTR 10496. EZM3800FSNFBTR EZM3800FSNBBTR 9220.
1000 18.66 1000 A Al EZM31000CBNFBTRiEZM31000CBNBBTRi12861. . . . . . . . . .
1200 30.19 1200 A Al/Cu EZM31200CBNFBTRgh EZM31200CBNBBTRgh 16929. . . . . . . . . .
Busway to LEFT of metering equipment lineup
400 18.66 800 A Al EZM3400CBNFBTL EZM3400CBNBBTL $5924. EZM3400FSNFBTL EZM3400FSNBBTL $4488.
600 18.66 800 A Al EZM3600CBNFBTL EZM3600CBNBBTL 8342. EZM3600FSNFBTL EZM3600FSNBBTL 7093.
800 18.66 800 A Al EZM3800CBNFBTL EZM3800CBNBBTL 10496. EZM3800FSNFBTL EZM3800FSNBBTL 9220.
1000 18.66 1000 A Al EZM31000CBNFBTLiEZM31000CBNBBTLi12861. . . . . . . . . .
1200 30.19 1200 A Al/Cu EZM31200CBNFBTLgh EZM31200CBNBBTLgh 16929. . . . . . . . . .
EZMK311400
56.11
1425
31.11
790
4.11
104
Floor Level
Top of EZM
Mounting
Channel
EZM
Bus Tap
C
L of Busway
Plug-in Opening
EZM3800CBNFBTR
Width
(See Note)
56.11
1425
31.11
790 4.11
104
Floor Level
Top of EZM
Mounting
Channel
EZM
Bus Tap
C
L of Busway
Plug-in Opening
EZM3800FSNBBTL
Width
(See Note)
For additional information, reference Catalog #4100CT9801.
DE4 Discount
Schedule
METERING EQUIPMENT
www.SquareD.com
For the most up-to-date information
50
Metering
EZ METER-PAK® Meter Centers
Tenant Circuit Breakers and Accessories
© 2004 Schneider Electric
All Rights Reserved
6/7/04
Accessories
Description Catalog Number Price
FIFTH JAW KIT (1 per kit) 5Jd$12.20
Secondary Surge Arrester Mounting Kit
For use with 1 or 2-SDSA1175 or 1-SDSA3650
(order surge arrester separately) MMSAMKe53.00
Transition Section, 1200 A (10.7" wide)
Add right of old style 1Ø EZM lineup EZM1TRANR 158.00
Add right of old style 3Ø EZM lineup EZM3TRANR 168.00
Add left of old style 1Ø EZM lineup EZM1TRANL 210.00
Add left of old style 3Ø EZM lineup EZM3TRANL 221.00
1200 A 1Ø3W BUSSED EXTENSION
(Indoor/Outdoor) EZM1EXT 511.00
1200 A 1Ø3W BUSSED CORNER for INSIDE CORNER
(NEMA 1 indoor only) EZM1CORNER 1192.00
1200 A 3Ø4W BUSSED EXTENSION
(Indoor/Outdoor) EZM3EXT 644.00
1200 A 3Ø4W BUSSED CORNER for INSIDE CORNER
(NEMA 1 indoor only) EZM3CORNER 1478.00
1200 A, 1-Phase, 3-Wire BUSSED ELBOW for OUTSIDE
CORNER (NEMA 1 indoor only) EZM1ELBOW 1192.00
1200 A, 3-Phase, 4-Wire BUSSED ELBOW for OUTSIDE
CORNER (NEMA 1 indoor only) EZM3ELBOW 1478.00
Stud Kit for 400 A TAP BOX includes (2) 1/2"-13 studs per
pad and mounting hardware. Four pads per kit. EZMSK2 164.00
Stud Kit for 800 A TAP BOX includes (4) 1/2"-13 studs per
pad and mounting hardware. Four pads per kit. EZMSK4 328.00
LEXAN METER SOCKET CLOSING PLATE
Not for use on commercial sockets. 29007 6.70
Q2 CIRCUIT BREAKER CLOSING PLATE EZMPCP 7.40
MOUNTING CHANNEL (72" long) EZM72MC 42.00
METAL CLOSING PLATE
For use only on Type EZML and EZMR (3Ø IN-3Ø OUT)
branch units.
RSG4 81.00
SEALING RINGS:
SNAP-ON (Stainless Steel) ARP00026 11.10
SCREW-Type (Aluminum) 29008W 13.40
LATCH-Type (Aluminum)-standard 2920910001 5.00
HORN BYPASS KIT
(use with type EZMR 1Ø meter socket only) MMHB 11.10
BARREL LOCK KIT
For use on ringless EZM or MP branch unit covers,
includes 6 each of head protectors, lock nuts and sealing
caps. (Barrel lock not included.)
MMBLC 44.10
QO ADAPTER for BOLT-ON Q-frame
Tenant Circuit Breakers (40–60 A, 2-Pole) EZM125QOA 182.00
EQUIPMENT GROUND TERMINAL . . . . Included
For additional information,
reference Catalog
#4100CT9801.
DE2A Discount
Schedule
aQO-VH tenant circuit breaker is rated 22 kA AIR max.
bQOH tenant circuit breaker is rated 42 kA AIR max.
c3-pole QJP tenant circuit breaker is rated 65 kA AIR max. at 240/120 Vac, 3-Phase, 4-Wire High Leg DELTA, or 100kA AIR max. at 208Y/120 Vac, 3-Phase,
4-Wire.
Tenant Circuit Breakers
Poles Ampere
Rating
10 kA AIR 22 kA AIR 42 kA AIR 100 kA AIR
Cat. No. Price Cat. No. Price Cat. No. Price Cat. No. Price
125 A Max. EZM Branch Unit Tenant Circuit Breakers
2
40 QO240 $44.70 QO240VH $97.00 QOH240 $211.00 . . . . . .
50 QO250 44.70 QO250VH 97.00 QOH250 211.00 . . . . . .
60 QO260 44.70 QO260VH 97.00 QOH260 211.00 . . . . . .
70 QO270 89.00 QO270VH 149.00 QOH270 352.00 . . . . . .
80 QO280 126.00 QO280VH 210.00 QOH280 434.00 . . . . . .
90 QO290 126.00 QO290VH 210.00 QOH290 434.00 . . . . . .
100 QO2100 126.00 QO2100VH 210.00 QOH2100 434.00 . . . . . .
110 QO2110 285.00 QO2110VH 689.00 QOH2110 926.00 . . . . . .
125 QO2125 285.00 QO2125VH 689.00 QOH2125 926.00 . . . . . .
225 A Max. EZM Branch Unit Tenant Circuit Breakers
10 kA AIR 25 kA AIR 65 kA AIR 100 kA AIR
2
40 QO240 $44.70 QO240VHa$97.00 QOH240b$211.00 . . . . . .
50 QO250 44.70 QO250VHa97.00 QOH250b211.00 . . . . . .
60 QO260 44.70 QO260VHa97.00 QOH260b211.00 . . . . . .
70 QBP22070TM 316.00 QDP22070TM 762.00 QGP22070TM 1014.00 QJP22070TM $1260.00
80 QBP22080TM 316.00 QDP22080TM 762.00 QGP22080TM 1014.00 QJP22080TM 1260.00
90 QBP22090TM 316.00 QDP22090TM 762.00 QGP22090TM 1014.00 QJP22090TM 1260.00
100 QBP22100TM 316.00 QDP22100TM 762.00 QGP22100TM 1014.00 QJP22100TM 1260.00
125 QBP22125TM 316.00 QDP22125TM 762.00 QGP22125TM 1014.00 QJP22125TM 1260.00
150 QBP22150TM 316.00 QDP22150TM 762.00 QGP22150TM 1014.00 QJP22150TM 1260.00
175 QBP22175TM 316.00 QDP22175TM 762.00 QGP22175TM 1014.00 QJP22175TM 1260.00
200 QBP22200TM 316.00 QDP22200TM 762.00 QGP22200TM 1014.00 QJP22200TM 1260.00
225 QBP22225TM 316.00 QDP22225TM 762.00 QGP22225TM 1014.00 QJP22225TM 1260.00
3
70 QBP32070TM $832.00 QDP32070TM $1189.00 QGP32070TM $1628.00 QJP32070TMc$1864.00
80 QBP32080TM 832.00 QDP32080TM 1189.00 QGP32080TM 1628.00 QJP32080TMc1864.00
90 QBP32090TM 832.00 QDP32090TM 1189.00 QGP32090TM 1628.00 QJP32090TMc1864.00
100 QBP32100TM 832.00 QDP32100TM 1189.00 QGP32100TM 1628.00 QJP32100TMc1864.00
125 QBP32125TM 832.00 QDP32125TM 1189.00 QGP32125TM 1628.00 QJP32125TMc1864.00
150 QBP32150TM 832.00 QDP32150TM 1189.00 QGP32150TM 1628.00 QJP32150TMc1864.00
175 QBP32175TM 832.00 QDP32175TM 1189.00 QGP32175TM 1628.00 QJP32175TMc1864.00
200 QBP32200TM 832.00 QDP32200TM 1189.00 QGP32200TM 1628.00 QJP32200TMc1864.00
225 QBP32225TM 832.00 QDP32225TM 1189.00 QGP32225TM 1628.00 QJP32225TMc1864.00
QO2100VH
2-Pole, Plug-on Type
Circuit Breaker
QDP22200TM
2-Pole, Bolt-on Type
Circuit Breaker
dAll sockets include 5th Jaw Factory installed except EZM11__ devices.
eConsult your nearest Square D/Schneider Electric sales office for details.
fMeter center short circuit current rating is 10,000 RMS symmetrical amperes with manual
circuit closers installed (bypass is not designed for use as continuous duty).
gFor use on ring type meter sockets only.
Busway Transition Section
EZM busway transition section provides no overcurrent protection for the
downstream EZM branch units. Tenant main circuit breakers in these
branch units must be selected as “fully rated” equipment. (Examples:
QO for 10 kA, QO-VH for 22 kA or QOH for 42 kA.)
SLIDER TYPE MANUAL CIRCUIT CLOSER
(for one Ring Type socket only):
125–200 A (Indoor/Outdoor) MM200MBfg 114.00
ANTI-INVERSION CLIP
Rejects use of 100 A and 200 A meters in Class 320
meter sockets in Type EZML branch units.
59676 5.30
Al/Cu Lug Kits (Each kit includes three, 2-barrel lugs.)
(1) #1/0–600 kcmil or (2) #1/0–250 kcmil per lug MMLK250 100.00
(2) #3/0–500 kcmil per lug MMLK500 133.00
(2) #2–600 kcmil per lug MMLK600 155.00
EZM Busway Transition Sections (three phase only)
Ampere Rating Neutral Front Neutral Back Width (IN) Price
I-LINE® Busway located on RIGHT side of EZM Transition Section
1200 EZM3BUSRF EZM3BUSRB 12.00 $2625.
I-LINE Busway located on LEFT side of EZM Transition Section
1200 EZM3BUSLF EZM3BUSLB 12.00 2625.
Accessories (Continued)
Description Catalog Number Price
4.11
104
56.11
1425
16.11
409
55.11
1400
1.00
25
Floor Level
Top of EZM
Mounting
Channel
EZM
Bus Tap
C
L of Busway
Plug-in Opening
EZM3BUSRF and EZM3BUSRB
4.11
104
56.11
1425
16.11
409
55.11
1400
1.00
25
Floor Level
Top of EZM
Mounting
Channel
EZM
Bus Tap
C
L of Busway
Plug-in Opening
EZM3BUSLF and EZM3BUSLB
Width Width
METERING EQUIPMENT
51
Metering
EZ METER-PAK® Meter Centers
Dimensions
© 2004 Schneider Electric
All Rights Reserved
6/7/04
www.SquareD.com
For the most up-to-date information
aEach leg of this corner section measures 14.72" from wall to start of next
enclosure.
bEach leg of elbow section measures 6.17" corner of wall to start of next
enclosure.
cDevice supplied without mounting channel, secure to wall by use of
swingable mounting feet.
dStandard branch units are available without suffix added.
Main Devices
Catalog Number Height
(H)
Width
(W)
Depth
(D)
Mtg.
Channel
(MC)
EZM11000CB 53.97 18.66 11.50 34.30
EZM11000CBU 70.05 34.19 18.33 46.99
EZM11200CB 61.19 30.19 18.33 38.13
EZM11200CBU 70.05 34.19 18.33 46.99
EZM11200FS 61.19 30.19 18.33 38.13
EZM11200FSU 70.05 34.19 18.33 46.99
EZM11200TB [CU] 51.58 22.33 13.00 27.92
EZM11200TBU [CU] 44.71 33.16 11.12 31.17
EZM11600CB 61.19 30.19 18.33 38.13
EZM11600CBU 71.19 30.19 18.33 48.12
EZM11600TB [CU] 51.58 22.33 13.00 27.92
EZM1225TB [CU] 21.81 11.50 5.81 13.00c
EZM1400CB 53.97 18.66 11.50 34.30
EZM1400CBU 69.03 20.46 11.50 49.37
EZM1400FS 53.97 18.66 11.50 34.30
EZM1400FSU 69.03 20.46 11.50 49.37
EZM1400TB [CU] 28.43 17.00 6.53 16.29
EZM1400TBU [CU] 35.71 17.16 8.00 27.17
EZM1600CB 53.97 18.66 11.50 34.30
EZM1600CBU 69.03 20.46 11.50 49.37
EZM1600FS 53.97 18.66 11.50 34.30
EZM1600FSU 69.03 20.46 11.50 49.37
EZM1600TB [CU] 28.43 17.00 6.53 16.29
EZM1800CB 53.97 18.66 11.50 34.30
EZM1800CBU 69.03 20.46 11.50 49.37
EZM1800FS 53.97 18.66 11.50 34.30
EZM1800FSU 69.03 20.46 11.50 49.37
EZM1800TB [CU] 51.76 23.93 6.41 28.01
EZM1800TBU [CU] 39.96 25.06 11.12 31.17
EZM1EXT 19.34 11.66 6.37 11.85c
EZM1CORNER
(indoor only)a19.50 14.40 8.02 11.85c
EZM1ELBOW
(indoor only)b19.50 14.52 8.01 11.85c
EZM31000CB 53.97 18.66 11.50 34.30
EZM31000CBU 70.05 34.19 18.33 46.99
EZM31200CB 61.19 30.19 18.33 38.13
EZM31200CBU 70.05 34.19 18.33 46.99
EZM31200TB [CU] 51.58 22.33 13.00 27.92
EZM31200TBU [CU] 44.71 33.16 11.12 31.17
EZM31600CB 61.19 30.19 18.33 38.13
EZM31600CBU 71.19 30.19 18.33 48.12
EZM31600TB [CU] 51.58 22.33 13.00 27.92
EZM3225TB [CU] 21.81 11.50 5.81 13.00c
EZM3400CB 53.97 18.66 11.50 34.30
EZM3400CBU 69.03 20.46 11.50 49.37
EZM3400FS 53.97 18.66 11.50 34.30
EZM3400FSU 69.03 20.46 11.50 49.37
EZM3400TB [CU] 28.43 17.00 6.53 16.29
EZM3400TBU [CU] 35.71 17.16 8.00 27.17
EZM3600CB 53.97 18.66 11.50 34.30
EZM3600CBU 69.03 26.19 11.65 49.37
EZM3600FS 53.97 18.66 11.50 34.30
EZM3600FSU 69.03 26.19 11.65 49.37
EZM3600TB [CU] 28.43 17.00 6.53 16.29
EZM3800CB 53.97 18.66 11.50 34.30
EZM3800CBU 69.03 26.19 11.65 49.37
EZM3800FS 53.97 18.66 11.50 34.30
EZM3800FSU 69.03 26.19 11.65 49.37
EZM3800TB [CU] 51.76 23.93 6.41 28.01
EZM3800TBU [CU] 39.96 25.06 11.12 31.17
EZM3EXT 19.34 11.66 6.37 11.85c
EZM3CORNER
(indoor only)a19.50 14.40 8.02 11.85c
EZM3ELBOW
(indoor only)b19.500 14.52 8.01 11.85c
H
W
T
B
MC (Mounting Channel)
MC (Mounting Channel)
H
W
Branch Device Main Device
For additional information,
reference Catalog #4100CT9801.
Branch Devices
Catalog Number
[available suffix]
Height
(H)
Width
(W)
Depth
(D)
Mtg.
Channel
(MC)
Top
Meter
(T)
Bottom
Meter
(B)
Single Phased
EZM112225 [X, CU, CUX] 43.41 17.38 8.09 32.34 22.18 12.23
EZM113125 [X, CU, CUX] 42.37 12.25 7.09 31.30 13.18 11.19
EZM113225 [X, CU, CUX] 43.41 17.38 8.09 32.34 13.18 12.23
EZM114125 [X, CU, CUX] 48.12 12.25 7.09 31.30 9.93 11.19
EZM114225 [X, CU, CUX] 52.00 17.38 8.09 32.34 12.77 12.23
EZM115125 [X, CU, CUX] 57.12 12.25 7.09 31.30 9.93 11.19
EZM115225 [X, CU, CUX] 61.00 17.38 8.09 40.03 12.77 12.23
EZM116125 [X, CU, CUX] 66.12 12.25 7.09 40.30 9.93 11.19
EZMH112225 [X, CU, CUX] 43.41 17.38 8.09 32.34 22.18 12.23
EZMH113125 [X, CU, CUX] 42.37 12.25 7.09 31.30 13.18 11.19
EZMH113225 [X, CU, CUX] 43.41 17.38 8.09 32.34 13.18 12.23
EZMH114125 [X, CU, CUX] 48.12 12.25 7.09 31.30 9.93 11.19
EZMH114225 [X, CU, CUX] 52.00 17.38 8.09 32.34 12.77 12.23
EZMH115125 [X, CU, CUX] 57.12 12.25 7.09 31.30 9.93 11.19
EZMH115225 [X, CU, CUX] 61.00 17.38 8.09 40.03 12.77 12.23
EZMH116125 [X, CU, CUX] 66.12 12.25 7.09 40.30 9.93 11.19
EZMK111400 45.55 27.56 9.74 37.81 24.51 21.04
EZMK112400 72.99 27.56 9.74 37.81 22.26 21.04
EZML111225 [CU] 39.06 19.44 9.44 25.51 25.67 13.39
EZML111225D 39.06 19.44 9.44 25.51 25.67 13.39
EZML111400 [CU] 44.55 23.21 9.44 37.81 24.02 21.53
EZML112225 [CU] 39.06 19.44 9.44 25.51 11.67 13.39
EZML112225D 39.06 19.44 9.44 25.51 11.67 13.39
EZML112400 [CU] 69.61 23.21 9.44 37.81 20.64 21.53
EZML113225 [CU] 53.06 19.44 9.44 39.51 11.67 13.39
EZML113225D 53.06 19.44 9.44 39.51 11.67 13.39
EZML114225 [CU] 67.06 19.44 9.44 39.51 11.67 13.39
EZML114225D 67.06 19.44 9.44 39.51 11.67 13.39
EZMR112225 [X, CU, CUX] 43.41 17.38 8.09 32.34 22.18 12.23
EZMR113125 [X, CU, CUX] 42.37 12.25 7.09 31.30 13.18 11.19
EZMR113225 [X, CU, CUX] 43.41 17.38 8.09 32.34 13.18 12.23
EZMR114125 [X, CU, CUX] 48.12 12.25 7.09 31.30 9.93 11.19
EZMR114225 [X, CU, CUX] 52.00 17.38 8.09 32.34 12.77 12.23
EZMR115125 [X, CU, CUX] 57.12 12.25 7.09 31.30 9.93 11.19
EZMR115225 [X, CU, CUX] 61.00 17.38 8.09 40.03 12.77 12.23
EZMR116125 [X, CU, CUX] 66.12 12.25 7.09 40.30 9.93 11.19
EZMT111225 25.45 22.42 9.38 16.19 4.67 20.45
EZMT112225 60.56 22.42 9.38 43.63 12.67 28.89
EZMT113225 79.56 22.42 9.38 48.25 12.67 28.89
Three Phased
EZM312225 [X, CU, CUX, CA, XCA, CUCA, CUXCA] 43.41 17.38 8.09 32.34 22.18 12.23
EZM313125 [X, CU, CUX, CA, XCA, CUCA, CUXCA] 42.37 12.25 7.09 31.30 13.18 11.19
EZM313125M10 42.37 12.25 7.09 24.29 10.18 12.19
EZM313225 [X, CU, CUX, CA, XCA, CUCA, CUXCA] 43.41 17.38 8.09 32.34 13.18 12.23
EZM314125 [X, CU, CUX, CA, XCA, CUCA, CUXCA] 48.12 12.25 7.09 31.30 9.93 11.19
EZM314125M10 52.12 12.25 7.09 34.29 9.93 12.19
EZM314225 [X, CU, CUX, CA, XCA, CUCA, CUXCA] 52.00 17.38 8.09 32.34 12.77 12.23
EZM315125 [X, CU, CUX, CA, XCA, CUCA, CUXCA] 57.12 12.25 7.09 31.30 9.93 11.19
EZM315125M10 62.12 12.25 7.09 34.29 9.93 12.19
EZM315225 [X, CU, CUX, CA, XCA, CUCA, CUXCA] 61.00 17.38 8.09 40.03 12.77 12.23
EZM316125 [X, CU, CUX, CA, XCA, CUCA, CUXCA] 66.12 12.25 7.09 40.30 9.93 11.19
EZMH312225 [X, CU, CUX, CA, XCA, CUCA, CUXCA] 43.41 17.38 8.09 32.34 22.18 12.23
EZMH313125 [X, CU, CUX, CA, XCA, CUCA, CUXCA] 42.37 12.25 7.09 31.30 13.18 11.19
EZMH313225 [X, CU, CUX, CA, XCA, CUCA, CUXCA] 43.41 17.38 8.09 32.34 13.18 12.23
EZMH314125 [X, CU, CUX, CA, XCA, CUCA, CUXCA] 48.12 12.25 7.09 31.30 9.93 11.19
EZMH314225 [X, CU, CUX, CA, XCA, CUCA, CUXCA] 52.00 17.38 8.09 32.34 12.77 12.23
EZMH315125 [X, CU, CUX, CA, XCA, CUCA, CUXCA] 57.12 12.25 7.09 31.30 9.93 11.19
EZMH315225 [X, CU, CUX, CA, XCA, CUCA, CUXCA] 61.00 17.38 8.09 40.03 12.77 12.23
EZMH316125 [X, CU, CUX, CA, XCA, CUCA, CUXCA] 66.12 12.25 7.09 40.30 9.93 11.19
EZMK311400 [CA] 45.55 27.56 9.74 30.60 24.51 21.04
EZMK312400 [CA] 72.99 27.56 9.74 37.81 22.26 21.04
EZMK331400 [CA] 45.55 27.56 9.74 30.60 24.51 21.04
EZMK332400 [CA] 72.99 27.56 9.74 37.81 22.26 21.04
EZML311400 [CU, CA, CUCA] 45.55 23.21 9.44 37.81 24.02 21.53
EZML311225 [CU, CA, CUCA] 39.06 19.44 9.44 25.51 25.67 13.39
EZML312225 [CU, CA, CUCA] 39.06 19.44 9.44 25.51 11.67 13.39
EZML312225D [CA] 39.06 19.44 9.44 25.51 11.67 13.39
EZML312400 [CU, CA, CUCA] 69.61 23.21 9.44 37.82 20.64 21.53
EZML313225 [CU, CA, CUCA] 53.06 19.44 9.44 39.51 11.67 13.39
EZML313225D [CA] 53.06 19.44 9.44 39.51 11.67 13.39
EZML314225 [CU, CA, CUCA] 67.06 19.44 9.44 39.51 11.67 13.39
EZML314225D [CA] 67.06 19.44 9.44 39.51 11.67 13.39
EZML331225 [CU] 39.06 19.44 9.44 25.51 25.67 13.39
EZML331225D 39.06 19.44 9.44 25.51 25.67 13.39
EZML331400 [CU] 45.55 23.21 9.44 37.81 24.02 21.53
EZML332225 [CU] 39.06 19.44 9.44 35.51 11.67 13.39
EZML332225D 39.06 19.44 9.44 35.51 11.67 13.39
EZML332400 [CU] 69.61 23.21 9.44 37.82 20.64 21.53
EZML333225 [CU] 53.06 19.44 9.44 39.51 11.67 13.39
EZML333225D 53.06 19.44 9.44 39.51 11.67 13.39
EZML334225 [CU] 67.06 19.44 9.44 39.51 11.67 13.39
EZML334225D 67.06 19.44 9.44 39.51 11.67 13.39
EZMR312225 [X, CU, CUX, CA, XCA, CUCA, CUXCA] 43.41 17.38 8.09 32.34 22.18 12.23
EZMR313125 [X, CU, CUX, CA, XCA, CUCA, CUXCA] 42.37 12.25 8.09 31.30 13.18 11.19
EZMR313225 [X, CU, CUX, CA, XCA, CUCA, CUXCA] 43.41 17.38 8.09 32.34 13.18 12.23
EZMR314125 [X, CU, CUX, CA, XCA, CUCA, CUXCA] 48.12 12.25 7.09 31.30 9.93 11.19
EZMR314225 [X, CU, CUX, CA, XCA, CUCA, CUXCA] 52.00 17.38 8.09 32.34 12.77 12.23
EZMR315125 [X, CU, CUX, CA, XCA, CUCA, CUXCA] 57.12 12.25 7.09 31.30 9.93 11.19
EZMR315225 [X, CU, CUX, CA, XCA, CUCA, CUXCA] 61.00 17.38 8.09 40.03 12.77 12.23
EZMR316125 [X, CU, CUX, CA, XCA, CUCA, CUXCA] 66.12 12.25 7.09 40.30 9.93 11.19
EZMR332225 [CU] 39.06 19.44 9.44 25.51 11.67 13.39
EZMR333225 [CU] 53.06 19.44 9.44 39.51 11.67 13.39
EZMR334225 [CU] 67.06 19.44 9.44 39.51 11.67 13.39
EZMT311225 [CA] 25.45 22.42 9.38 16.19 4.67 20.45
EZMT312225 [CA] 60.56 22.42 9.38 43.63 12.67 28.89
EZMT313225 [CA] 79.56 22.42 9.38 48.25 12.67 28.89
EZMT331225 25.12 22.42 9.38 16.19 4.67 20.45
EZMT332225 60.56 22.42 9.38 43.63 12.67 28.89
EZMT333225 79.56 22.42 9.38 48.25 12.67 28.89
METERING EQUIPMENT
www.SquareD.com
For the most up-to-date information
52
Metering
EZ METER-PAK® Meter Centers
Indoor/Rainproof
© 2004 Schneider Electric
All Rights Reserved
6/7/04
For additional information, reference Catalog #4100CT9801.
240 Vac Maximum, NEMA 3R Construction Meter Centers for use on AC-Systems. Suitable for use as Service
Equipment.
Utility Company Requirements: Review local utility requirements to
ensure that metering equipment meets their standards.
EZ METER-PAK meter center enclosures meet NEC wire bending
requirements, and are designed for wall mounting only (not suitable for
floor mounting). All unmetered conductor compartments are sealable by
the utility company.
EZ METER-PAK meter centers have UL Listed short circuit current
ratings up to 100,000 RMS symmetrical amperes at 240 Vac when
properly applied. Refer to table below for details and appropriate
downstream load centers and panelboards.
Suitable incoming services for an EZM main device and available
outgoing feeder(s) to downstream panelboards from EZM branch
section(s):
Incoming Service to Main Device 120/240 Vac, 1Ø3W:
Available outgoing feeder(s) to downstream panelboards:
120/240 Vac, 1Ø3W
(4-jaw ring type meter sockets, 2-pole circuit breakers)
(5-jaw ringless meter sockets, 2-pole circuit breakers)
Incoming Service to Main Device 240/120 Vac, 3Ø4W Delta:
Available outgoing feeder(s) to downstream panelboards:
120/240 Vac, 1Ø3W
(Fed from transformer’s “A-Phase” and “C-Phase” only.) NOTE:
Connection to High-Leg “B-Phase” not permitted for this service
(4-jaw ring type meter sockets, 2-pole circuit breakers)
(5-jaw ringless meter sockets, 2-pole circuit breakers)
Standard 3-Phase IN/1-Phase OUT branch units are not suitable
for use on this DELTA System. Special branch units are available
for this System by adding suffix: “CA” to catalog number (Typical
Examples: EZM313125CA, EZMH314200CA, etc.).
240/120 Vac, 3Ø4W Delta
(7-jaw meter sockets, 3-pole circuit breakers)
Incoming Service to Main Device 208Y/120 Vac, 3Ø4W:
Available outgoing feeder(s) to downstream panelboards:
120/208 Vac, 1Ø3W
(5-jaw meter sockets, 2-pole circuit breakers)
208Y/120 Vac, 3Ø4W
(7-jaw meter sockets, 3-pole circuit breakers)
Main Devices:
1200 A main disconnect or terminal box must be center mounted
when used with branch devices with main bus rated 800 A.
1600 A main disconnect or terminal box must be center mounted.
400, 800 and 1200 A type EZM-TBU tap boxes supplied with lug
landings to meet EUSERC requirements.
Main Circuit Breaker, ratings: 400, 600, 800, 1000, 1200, and 1600 A
Main Fusible Switch, ratings: 400, 600, 800, and 1200 A (1 phase, 3
wire only)
Main Lugs Terminal Box, ratings: 225 A, 400, 600, 800, 1200, and
1600 A
Branch Unit:
125 A and 225 A residential branch units, available in ring or
ringless type construction and supplied with 800 A horizontal
cross bus. For all-copper bussing, add suffix “CU” to catalog
number (Example: EZM314125CU). Plug-in style meter sockets
are available as ring type EZM without bypass, ringless type EZMR
without bypass, and ringless type EZMH with horn bypass. For
1200 A main cross bus, add suffix “X” to catalog number
(Example: EZM314125X).
225 A commercial branch units, available in ring or ringless type
construction and supplied with 1200 A horizontal cross bus. For
all-copper bussing, add suffix “CU” to catalog number (Example:
EZML334200CU). Plug-in style meter sockets are available as
ringless type EZMR without bypass, ringless type EZML with lever
bypass and ring type EZMT with test block bypass (meets
EUSERC requirements).
400 A branch units, Type EZML branch units are available in
ringless type construction, supplied with 1200 A AL/CU
(standard), or 1200 A copper (add suffix “CU” ) horizontal cross
bus. This plug-in meter socket is supplied with lever bypass and
jaw release. Type EZMK branch units are supplied with 1200 A
copper (standard) horizontal cross bus. This bolt-on meter socket
is supplied with a manual bypass.
Units having 800 A horizontal cross bus WILL CONNECT with
units having 1200 A horizontal cross bus.
Single Phase units (three bus bars in horizontal cross bus) WILL
NOT CONNECT with three phase units (four bus bars in
horizontal cross bus).
aFor additional information, refer to Data Bulleting #4100DB0301.
Square D Certified Ratings for Downstream Panelboards:a
For load centers or panelboards installed downstream from
any UL Listed MP METER-PAK (single phase only)
or EZ METER-PAK meter center applied on a system
capable of delivering greater than 10,000 RMS symmetrical
amperes. Requires a minimum of 20 feet of cable between
meter center and downstream load center or panelboard.
all ratings verified by actual Square D tests.
Meter Center 125 A and
225 A Branch Units
QO Load Centers or NQOD Panelboards with
Branch Circuit Breakers rated 10,000 AIR
HOM Load Centers with Branch
Circuit Breakers rated 10,000
AIR
Downstream
Single Phase Load Center
or Panelboard
QO, QOB – 1-Pole (15 A–70 A)
QOT–1-Pole (15 A–70 A)
QO-GFI, QOB-GFI–1-Pole (15 A–30 A)
QO-AFI, QOB-AFI–1-Pole (15 A–20A)
QO, QOB–2-Pole (15 A–125 A)
HOM–1-Pole (15 A–50 A)
HOMT–1-Pole (15 A–20 A)
HOM-AFI–1-Pole (15A–20A)
HOM-GFI–1-Pole (15 A–20 A)
HOM–2-Pole (15 A–70 A)
HOMT–2-Pole (15 A–30 A)
Downstream
Three Phase Load Center
or Panelboard
QO, QOB– 1-Pole (15 A–70 A)
2-Pole (15 A–125 A)
3-Pole (15 A–100 A)
QO-AFI, QOB-AFI–1-Pole (15 A–20 A)
QO-GFI, QOB-GFI–1-Pole (15 A–30 A)
. . .
METERING EQUIPMENT
53
Metering
EZ METER-PAK® Meter Centers
Short Circuit Current Ratings
© 2004 Schneider Electric
All Rights Reserved
6/7/04
www.SquareD.com
For the most up-to-date information
Selection Information
Review local utility
requirements to ensure
that metering equipment
meets their standards.
Check local utility to
determine available fault
current at the meter center.
Using the SCCR table:
Select meter center
configuration, main lugs
only (6-Subdivision
Rule), or remote main,
main circuit breaker, or
main fusible switch.
Read down to select
SCCR equal to, or
greater than desired
rating.
Read across to select
branch unit tenant
circuit breaker type.
— Continue reading
across to select EZM
main device type.
With information obtained
from table below, turn to
appropriate selection/
pricing pages to determine
catalog numbers for main
device, branch units, and
tenant circuit breakers to
complete meter center.
Refer to “Square D
Certified Ratings” table on
page 52 to determine
suitable downstream load
centers or panelboards.
Load
Centers
(Main Lugs)
Transformer
Service
Disconnects
(6 Max.)
EZM Main Lugs Terminal Box
EZM Branch Units
Figure 1
Tenant
Circuit
Breakers
Load
Centers
(Main Lugs)
Transformer
EZM Main Lugs Terminal Box
EZM Branch Units
Upstream Disconnection
Means and Overcurrent
Protection as required
Figure 2
Load
Centers
(Main Lugs)
Transformer
EZM Circuit Breaker Main
or EZM Main Fusible Switch
Tenant
Circuit
Breakers
EZM Branch Units
Figure 3
aMeter center short circuit current rating is equal to the lowest short circuit current rating given in the table for any circuit breaker installed in any meter
panelboard in the meter center.
bShort circuit current rating is measured at the LINE SIDE terminals of the integral mounted or remote mounted main providing overcurrent protection for
the EZM metering equipment lineup.
cLimited to 208Y/120 Vac maximum (3-pole circuit breaker only).
dRequires use of EZM125QOA adapter (order separately). Refer to page 50 for pricing.
eSupplied with 400 A circuit breaker(s) factory installed, consult local field office for ordering other ampere ratings.
fSupplied with factory installed circuit breaker(s), with an adjustable trip rating range of 160–400 A.
UL Listed Meter Center Short Circuit Current Ratings (SCCR)
Short Circuit
Current Rating
(RMS Symmetrical
Amperes at
240 Vac
Maximum)ab
EZM Meter Center Overcurrent Protection Devices
EZM Branch Unit Tenant Circuit Breaker
Types Available
(Branch Unit Amperes max., Number of
Poles, Tenant Circuit Breaker Amperes
Rating Range)
EZM Main Device
with Integral Mounted Main,
Remote Mounted Main or
without an Upstream Mounted Main
(6-Sub-Division Rule)
EZ METER-PAK (6-Subdivision Rule Applications)—See Figure 1
10,000
QO (125 A, 2-Pole, 40–125 A)
225–1600 A Main Lugs Terminal Box
(Tenant Circuit Breakers used as Service Disconnects—6 maximum)
QO (225 A, 2-Pole, 40–125 A)e
QB (225 A, 2 or 3-Pole, 70–225 A)
18,000 LAL (400 A, 2 or 3-Pole, 125–400 A)e
22,000 QO-VH (125 A, 2-Pole, 40–125 A )
QO-VH (225 A, 2-Pole, 40–60 A)e
25,000 QD (225 A, 2 or 3-Pole, 70–225 A)
42,000 QOH (125 A, 2-Pole, 40–125 A)
QOH (225 A, 2-Pole, 40–60 A)e
65,000 QG (225 A, 2 or 3-Pole, 70–225 A)
100,000
QJ (225 A, 2-Pole only, 70–225 A)
QJ (225 A, 3-Pole only, 70–225 A) c
DJM (400 A, 2 or 3-Pole, 160–400 A)f
EZ METER-PAK—Main Lugs Terminal Box Applications Protected By Remote Main—See Figure 2
10,000
QO (125 A, 2-Pole, 40–125 A) 225–1600 A Main Lugs Terminal Box Must be protected by an Upstream
Disconnecting Means Rated 10,000 AIR minimum
QO (225 A, 2-Pole, 40–125 A)e
QB (225 A 2 or 3-Pole, 70–225 A)
18,000 LAL (400 A, 2 or 3-Pole, 125–400 A)e225–1600 A Main Lugs Terminal Box Must be protected by an Upstream
Disconnecting Means Rated 18,000 AIR minimum
22,000 QO-VH (125 A, 2-Pole, 40–125 A) 225–1600 A Main Lugs Terminal Box Must be protected by an Upstream
Disconnecting Means Rated 22,000 AIR minimumQO-VH (225 A, 2-Pole, 40–60 A)e
25,000 QD (225 A 2 or 3-Pole, 70–225 A) 225–1600 A Main Lugs Terminal Box Must be protected by an Upstream
Disconnecting Means Rated 25,000 AIR minimum
42,000
QOH (125 A, 2-Pole, 40–125 A) 225–1600 A Main Lugs Terminal Box Must be protected by an Upstream
Disconnecting Means Rated 42,000 AIR minimumQOH (225 A, 2-Pole, 40–60 A)e
QO-VH (125 A, 2-Pole, 40–125 A)
225–1600 A Main Lugs Terminal Box Must be protected by a Square D Circuit Breaker
Type LA (400 A max.) or MA (800 A max.) Rated 42,000 AIR minimum
QO-VH (225 A, 2-Pole, 40–60 A)e
QD (225 A 2 or 3-Pole, 70–225 A)
DJM (400 A, 2 or 3-Pole,160–400 A)f
65,000
QG (225 A 2 or 3-Pole, 70–225 A) 225–1600 A Main Lugs Terminal Box Must be protected by an Upstream
Disconnecting Means Rated 65,000 AIR minimum
QO-VH (125 A, 2-Pole, 40–125 A) 225–1600 A Main Lugs Terminal Box Must be protected by a Square D Circuit Breaker
Type LH (400 A max.), MH (1000 A max.) or PA (1600 A max.) Rated 65,000 AIR
minimum
QO-VH (225 A, 2-Pole, 40–60 A)e
QD (225 A 2 or 3-Pole, 70–225 A)
DJM (400 A, 2 or 3-Pole, 160–400 A)f
QD (225 A 2 or 3-Pole, 70–225 A)
225–1600 A Main Lugs Terminal Box Must be protected by a Square D Circuit Breaker
Type MG (800 A max.), PG (1200 A max.) or RG (1600 A max.) Rated 65,000 AIR
minimum
100,000
QJ (225 A 2-Pole only, 70–225 A ) 225–1600 A Main Lugs Terminal Box Must be protected by an Upstream
Disconnecting Means Rated 100,000 AIR minimumQJ (225 A 3-Pole only, 70–225 A)
QO-VH (125 A, 2-Pole, 40–125 A) Must be protected by an Upstream Disconnection Means with Class R (600 A max.),
or Class T (300 Vac, 800 A maximum) fuses.
QO-VH (225 A, 2-Pole, 40–60 A)e
DJM (400 A, 2 or 3-Pole, 160–225 A)f
QD (225 A 2-Pole only, 70–225 A) Must be protected by an Upstream Disconnection Means with Class J (600 A max.),
Class L (1200 A max.), Class R (600 A max.), Class T (300 Vac, 1200 A max.) or
Class T (600 Vac, 800 A maximum) fuses. Or be protected by a Square D circuit
breaker Type MJ (800 A max.), PJ (1200 A max.), PH (1600 A max.) or RJ (1600 A
max.) Rated 100,000 AIR minimum.
QD (225 A 3-Pole only, 70–225 A)c
EZ METER-PAK—Main Circuit Breaker Applications—See Figure 3
10,000
QO (125 A, 2-Pole, 40–125 A)
400–1600 A EZM Main Device with Type LH (400 A max.), MH (1000 A max.) or PA
(1600 A max.) Circuit Breaker.
QO (225 A, 2-Pole, 40–125 A)e
QB (225 A 2 or 3-Pole, 70–225 A)
18,000 LAL (400 A, 2 or 3-Pole, 120–400 A)e
65,000
QO-VH (125 A, 2-Pole, 40–125 A)
QO-VH (225 A, 2-Pole, 40–60 A)e
QD (225 A 2 or 3-Pole, 70–225 A)
DJM (400 A, 2 or 3-Pole, 160–400 A)
100,000
QO-VH (125 A, 2-Pole, 40–125 A)
1000–1200 A Main Device with Catalog Number Suffix "CBU" supplied with Type
MHF Circuit Breaker.
QO-VH (225 A, 2-Pole, 40–60 A)e
QD (225 A 2-Pole only, 70–225 A)
QD (225 A 3-Pole only, 70–225 A)c
DJM (400 A, 2 or 3-Pole, 160–400 A)f
EZ METER-PAK—Main Fusible Switch Applications—See Figure 3
10,000
QO (125 A, 2-Pole, 40–125 A)
400–800 A EZM Main Device (1-Phase or 3-Phase) with Class T (300 Vac) Fuses
installed.
QO (225 A, 2-Pole, 40–125 A)e
QB (225 A 2 or 3-Pole, 70–225 A)
18,000 LAL 400 A, 2 or 3-Pole, 125–400 A)e
42,000 QO-VH (125 A, 2-Pole, 40–125 A)
1200 A EZM Main Device (1-Phase only) with Class T (300 Vac) Fuses installed.
QO-VH (225 A, 2-Pole, 40–60 A)e
65,000 DJM (400 A, 2-Pole, 160–400 A)f
100,000 QD (225 A 2-Pole, 70–225 A)
100,000
QO-VH (125 A, 2-Pole, 40–125 A)
400–800 A EZM Main Device (1-Phase or 3-Phase) with Class T (300 Vac) Fuses
installed.
QO-VH (225 A, 2-Pole, 40–60 A)e
QD (225 A 2-Pole only, 70–225 A)
QD (225 A 3-Pole only, 70–225 A)c
DJM (400 A, 2 or 3-Pole, 160–400 A)f
For additional information, reference Catalog #4100CT9801.
Switches
&
DISCONNECTS
Safety Switches
In 1909 Thomas Edison chose a Square D safety switch for his laboratories
in Philadelphia. Today, Square D safety switches are still the best choice for
performance and reliability. That’s why professionals choose Square D
safety switches 2:1 over any other brand.
General Duty Switches
Square D general duty safety switches meet the needs of residential and
commercial applications with many features designed for economy, safety,
and superior performance. They are ideal for lighting, air conditioning, and
appliance loads up to 240 Vac. In addition, they may be used as
service entrance equipment.
Simplifies installation, operation, and maintenance while saving money.
Rugged enclosures built to last.
Padlock provisions.
Operating mechanism exceeds the number of operations required by
NEMA and UL standards.
54
SAFETY SWITCHES
55
General Duty Safety Switches
Light Duty
Class 3130
© 2004 Schneider Electric
All Rights Reserved
6/7/04
www.SquareD.com
For the most up-to-date information
General Duty—
Up To 100,000 A Short Circuit Current Rating With Proper Current Limiting Fusing
General duty safety switches are designed for residential and commercial applications where economy is a prime
consideration. Typical loads are lighting, air conditioning and appliances. They are suitable for use as service
equipment when equipped with a factory-installed neutral assembly or a field-installed service grounding kit.
General duty safety switches are UL Listed, File E2875, and meet or exceed the NEMA Standard KS1.
400 and 600 A general duty switches (NEMA 1 only) will accept Class J fuses and are UL Listed for use on systems
with up to 100,000 RMS symmetrical amperes available fault current. 600 A requires Class J fuse kit—GDJK600
(page 56).
Class T 400–800 A general duty safety switches, use 300 Vac Class T fuses and are UL Listed for use on systems
with up to 100,000 RMS symmetrical amperes available fault current.
aBolt-on hubs—Refer to page 62.
bWhen installed, this kit rejects all but Class R fuses. When installed with this kit and Class R fuses, the switch is UL Listed for use on systems with up
to 100,000 RMS symmetrical amperes available fault current.
cFor corner grounded delta systems only. Use switching poles for ungrounded conductors.
dSuitable for use as service equipment requires field installation of a service grounding kit (page 56).
eEnclosed molded case switch—Refer to page 29.
fIncludes factory installed grounding kit.
gNot service entrance rated—Refer to page 33 for more information.
hIncludes factory installed neutral.
iFor service equipment use or when neutral is required, order part number SN0610 at $71.00.
jSuitable for use as service equipment, requires field installation of neutral assembly SN20A at $133.00.
kSuitable for use as service equipment requires field installation of neutral assembly D600SN at $153.00.
lFor 200% neutral, order (1) additional neutral kit SN20A at $133. and (1) neutral jumper kit SN20NI at $18.40.
mIf corner grounded delta, install neutral and use outer switching poles for ungrounded conductors.
nIf corner grounded delta, use outer switching poles for ungrounded conductors.
Fusible
System Amps Fuse
NEMA 1
Indoor
NEMA 3Ra
Rainproof
Class R Fuse Kits
Field Installableb
Horsepower Ratings
Std.
(Using Fast Acting-
One Time Fuses)
Max.
(Using Dual Element-
Time Delay Fuses)
Catalog
Number Price Catalog
Number Price Catalog
Number Price
1Ø 3Ø
2 Wire (1 Blade and Fuseholder, 1 Neutral)—120 Vac
30 Plug Use Light Duty Device for This Application (see below)
30 Cart. Use 3 Wire Devices
for this application. –– – –
3 Wire (2 Blades and Fuseholders, 1 Neutral)—120/240 Vac (Plug), 240 Vac (Cart.) Maximum
30 Plug D211N $60.00 D211NRB $118.00 112–3
30 Cart. D221N 81.00 D221NRB 125.00 DRK 30 $17.10 1123c37
12c
60 Cart. D222N 137.00 D222NRB 217.00 RFK 03H 17.00 37
12c10 15 c
100 Cart. D223N 284.00 D223NRB 320.00 RFK 10 31.80 71215 c15 30 c
200 Cart. D224Nl589.00 D224NRBl800.00 HRK 1020 31.80 15 25 c–60c
400 Cart. D225N 1703.00 D225NR 2306.00 DRK 40 74.00 –– – –
600 Cart. D226N 3406.00 D226NR 4379.00 DRK 600 74.00 –– – –
4 Wire (3 Blades and Fuseholders, 1 Neutral)—240 Vac Maximum
30 Cart. D321N $125.00 D321NRB $195.00 DRK 30 $17.10 112337
12
60 Cart. D322N 217.00 D322NRB 294.00 RFK 03H 17.00 37
12n10 15n
100 Cart. D323N 376.00 D323NRB 544.00 RFK 10 31.80 71215n15 30n
200 Cart. D324Nl801.00 D324NRBl974.00 HRK 1020 31.80 15 25n–60n
400 Cart. D325N 2075.00 D325NR 2595.00 DRK 40 74.00 –50 –125
400 Class T D325NT 1996.00 D325NTR 2494.00 –50 –
600 Cart. D326N 3882.00 D326NR 5251.00 DRK 600 74.00 –75 –150
600 Class T D326NT 3732.00 D326NTR 5046.00 –75 –
800 Class T T327N 6481.00 T327NR 8292.00 100 –
Not Fusible
System Amps NEMA 1 Indoor NEMA 3R RainproofaHorsepower Ratings (Max.)
Catalog Number Price Catalog Number Price
2 Wire (2 Blades)—240 Vac Maximum
30 – DU221RBd$118.00 3–
60 – DU222RBd235.00 10 –
60 QO260NATSef $107.00 QO200TR efg 112.00 10 –
100 QO2000NSeh 184.00 QO2000NRBeh 225.00 20 –
200 Use 3-pole Switch Use 3-pole Switch
400 Use 3-pole Switch Use 3-pole Switch
600 Use 3-pole Switch Use 3-pole Switch
3 Wire (3 Blades)—240 Vac Maximum
30 DU321d$103.00 DU321RBd$195.00 37
12
60 DU322d137.00 DU322RBd295.00 10 15
100 DU323i318.00 DU323RBi544.00 15 30
200 DU324j589.00 DU324RBj974.00 15 60m
400 DU325d1465.00 ––125
600 DU326k2794.00 ––150
D223N
oThe UL Listed short-circuit current rating
for Square D general duty, not fusible
switches is based on the switch being
used in conjunction with fuses.
Evaluation of not fused switches in
conjunction with molded case circuit
breakers has not been performed. If a
UL Listed short-circuit current rating is
required, this not fused switch must be
replaced with a Square D general duty
fusible safety switch equipped with the
appropriate class and size fusing. The
UL Listed short-circuit current rating of
the fusible switch is typically as follows;
when used with Class H & K fuses—
10,000 A, Class R and J fuses—
100,000 A. Consult the wiring diagram
of the switch to verify the UL Listed
short-circuit current rating.
p50,000 amperes for 60 A not fusible
switch.
UL LISTED SHORT CIRCUIT
WITHSTAND RATING
(RMS SYMMETRICAL AMPERES)
Switch
Type
Fuse
Class
Short Circuit
Rating
Fusible Plug 10,000
H10,000
K10,000
J100,000
R100,000
T100,000
Not Fusible H 10,000
oK10,000
J100,000
R100,000p
T100,000
L211N
kDE1A DE2A Discount
Schedule
Light Duty—Visible Blades 10,000 A Short Circuit Current Rating
The Square D light duty enclosed switch is ideal for home applications in disconnecting power to workshops, hobby rooms, furnaces and garages.
Fusible
System Amps Fuse NEMA 1 Indoor Horsepower Ratings
Catalog Number PricekStd. Max.
2 Wire (1 Blade and Fuseholder, 1 Neutral)—120 Vac
30 Plug L111N $35.90 122
qFor single phase hp rating, use two switching poles.
3 Wire (2 Blades and Fuseholders, 1 Neutral)—120/240 Vac
30 Plug L211N $47.80 112q3q
30 Cart. L221N 65.00 112q3q
Fusible
System Amps Fuse NEMA 1 Indoor Horsepower Ratings
Catalog Number PricekStd. Max.
SAFETY SWITCHES
www.SquareD.com
For the most up-to-date information
56
General Duty Safety Switches
Accessories, Lug Data and Dimensions
Class 3130
© 2004 Schneider Electric
All Rights Reserved
6/7/04
b30–100 A switches suitable for 60°C or 75°C conductors. 200–800 A switches suitable for 75°C conductors.
Field Installable Fuse Puller Kits
Kit consists of three fuse pullers as required for a 3-pole, fusible, 60 and 100 ampere
general duty switch. Kits can be installed in 60 and 100 ampere Series F switches.
Description Catalog Number Price
Series F 60 Ampere Fuse Puller Kit FPK03 $20.00
Series F 100 Ampere Fuse Puller Kit FPK0610 28.40
Field Installable Service Grounding Kits
Switch Ampere
Rating
Catalog
Number Price Wire Size
AWG
30 PK3GTA1 $7.60u
(2) #12 Cu or
(2) #10 Al or
(1) #4 Al/Cu Max.
Series E 60 PK3GTA1 7.60u
(2) #12 Cu or
(2) #10 Al or
(1) #4 Al/Cu Max.
Series F 60 GTK03 7.60
(2) #12 Cu or
(2) #10 Al or
(1) #4 Al/Cu Max.
100 GTK0610 12.60 (2) #1/0 Al/Cu Max.
200 PKOGTA2 36.80 (2) #2/0 Al/Cu Max.
400 PKOGTA2 36.80 (2) #2/0 Al/Cu Max.
600 (Two Required) Per Lug
800 PKOGTA3 82.00 (6) #3/0 Al/Cu Max.
Terminal Lug Data b
Ampere
Rating
Conductors
Per Phase
Wire Range
Wire Bending Space Per NEC Table 373-6
AWG/kcmil
Lug Wire Range
AWG/kcmil
30 1 #12–6 (Al) or #14–6 (Cu) #12–6 (Al) or #14–6 (Cu)
60 1 #10–3 (Al) or #14–3 (Cu) #10–2 (Al) or #14–2 (Cu)
100 1 #12–1 (Al) or #14–1 (Cu) #12–1/0 (Al) or #14–1/0 (Cu)
200 1 #6 –250 (Al/Cu) #6 –300 (Al/Cu)
400
NEMA 1
1
or
2
#1/0 –600 (Al/Cu)
or
#1/0 –300 (Al/Cu)
(1) #1/0 –750 (Al/Cu)
or
(2) #1/0 –300 (Al/Cu)
400
NEMA 3R 2#1/0–250 (Al/Cu)
(1) #1 –600 (Al/Cu)
or
(2) #1/0 –250 (Al/Cu)
600 2 #4 –500 (Al/Cu) #4 –600 (Al/Cu)
800 3 #3/0 –500 (Al/Cu) #3/0 –500 (Al/Cu)
Field Installable Lug Kit
Kit consists of three line, three load and two neutral lugs as required for a 3-pole 400 A or
600 A general duty switch. Kit can be installed on 400 or 600 A Series E3 switches. This
kit applicable to NEMA 1 enclosures only.
Switch Ampere Rating Lug Kit Catalog Number Wire Range/NEC
AWG/kcmil
Lug Wire Range
AWG/kcmil Price
400 or 600 A Series E3 GD4060LK
(1) 1/0–600 (2) 1/0–600
(4) 1/0–250 $269.(2) 1/0–500
(4) 1/0–250
Field Installable Electrical Interlock Kits
Electrical interlocks for Series F 100–200 A general duty
safety switches and Series F 60 A fusible general duty
safety switches are available in kit form for field installation.
Each kit contains instructions for proper field mounting. A
pivot arm operates from switch mechanism, breaking the
control circuit before the main switch blades break.
Switches with electrical interlocks installed are UL Listed.
aElectrical interlock kit catalog numbers with -1 suffix indicates one normally
open and one normally closed contact; -2 indicates two normally open and
two normally closed contacts. Kits are UL Listed.
Electrical Interlock Kit
Switch
Ampere Rating
Electrical Interlock Kit
Catalog NumberaPrice
Fusible Series F 60 EIK031 or EIK032 $145.
Series F 100–200 EIK1 or EIK2 207.
Field Installable Class J Fuse Kit
Kit consists of three Class J fuse adapters as required for
3-Pole, fusible 600 A General Duty switch. Kit can be
installed in 600 A series E3 switches only (NEMA 1).
Switch
Ampere Rating
Class J Kit
Catalog Number Price
600 A Series E3 GDJK600 $195.
Approximate Dimensions
H
D
W/H
W
uDE3A DE1 Discount
Schedule
cDoes not have a cover draw as indicated in above drawing.
Catalog
Number Series HWW/HD
Std.
Pack
IN mm IN mm IN mm IN mm
L111N E2 7.63 194 5.00 127 6.13 156 4.00 102 1
L211N E2 7.63 194 5.00 127 6.13 156 4.00 102 1
L221N E2 7.63 194 5.00 127 6.13 156 4.00 102 1
D211NcE3 9.25 235 6.75 171 7.25 184 3.63 92 5
D211NRBcE2 9.63 245 7.25 184 7.75 197 3.75 95 5
D221NcE3 9.25 235 6.75 171 7.25 184 3.63 92 5
D221NRBcE3 9.63 245 7.25 184 7.75 197 3.75 95 5
D222N F1 14.63 372 6.50 165 7.45 189 4.88 124 1
D222NRB F1 14.88 378 6.63 168 7.45 189 4.88 124 1
D223N F3 17.50 445 8.50 216 10.50 267 6.50 165 1
D223NRB F3 17.50 445 8.50 216 10.50 267 6.50 165 1
D224N F1 29.00 737 17.25 438 19.00 483 8.25 210 1
D224NRB F1 29.25 743 17.25 438 19.00 483 8.25 210 1
D225N E3 45.12 1146 24.00 610 24.88 632 8.88 226 1
D225NR E1 30.63 778 21.38 543 22.25 565 10.13 257 1
D226NcE3 49.13 1248 24.00 610 24.88 632 8.88 226 1
D226NRcE1 49.13 1248 24.75 629 25.13 638 8.88 226 1
D321NcE3 9.25 235 6.75 171 7.25 184 3.63 92 5
D321NRBcE3 9.63 245 7.25 184 7.75 197 3.75 95 5
D322N F1 14.63 372 6.50 165 7.45 189 4.88 124 1
D322NRB F1 14.88 378 6.63 168 7.45 189 4.88 124 1
D323N F3 17.50 445 8.50 216 10.50 267 6.50 165 1
D323NRB F3 17.50 445 8.50 216 10.50 267 6.50 165 1
D324N F1 29.00 737 17.25 438 19.00 483 8.25 210 1
D324NRB F1 29.25 743 17.25 438 19.00 483 8.25 210 1
D325NcE3 45.12 1146 24.00 610 24.88 632 8.88 226 1
D325NTcE3 45.12 1146 24.00 610 24.88 632 8.88 226 1
D325NRcE1 30.63 778 21.38 543 22.25 565 10.13 257 1
D325NTRcE1 30.63 778 21.38 543 22.25 565 10.13 257 1
D326NcE3 49.13 1248 24.00 610 24.88 632 8.88 226 1
D326NTcE3 49.13 1248 24.00 610 24.88 632 8.88 226 1
D326NRcE1 49.13 1248 24.75 629 25.13 638 8.88 226 1
D326NTRcE1 49.13 1246 24.75 629 25.13 638 8.88 226 1
DU221RBcE2 9.63 245 7.25 184 7.75 197 3.75 95 5
DU222RBcE1 9.63 245 7.25 184 7.75 197 3.75 95 5
DU321cE2 9.25 235 6.75 171 7.25 184 3.63 92 5
DU321RBcE2 9.63 245 7.25 184 7.75 197 3.75 95 5
DU322cE1 9.25 235 6.75 171 7.25 184 3.63 92 5
DU322RBcE1 9.63 245 7.25 184 7.75 197 3.75 95 5
DU323 F3 17.50 445 8.50 216 10.50 267 6.50 165 1
DU323RB F3 17.50 445 8.50 216 10.50 267 6.50 165 1
DU324 F1 29.00 737 17.25 438 19.00 483 8.25 210 1
DU324RB F1 29.25 743 17.25 438 19.00 483 8.25 210 1
DU325cE3 45.12 1146 24.00 610 24.88 632 8.88 226 1
DU326cE3 49.13 1248 24.00 610 24.88 632 8.88 226 1
QO200TRcG3 6.50 165 4.63 118 . . . . . . 3.88 99 5
QO260NATScE2 9.25 235 4.88 124 . . . . . . 3.25 83 1
QO2000NRBcE1 14.00 356 7.75 197 . . . . . . 4.50 114 1
QO2000NScE1 13.38 340 6.13 156 . . . . . . 3.50 89 1
T327NcE1 49.13 1248 24.00 610 24.88 632 8.88 226 1
T327NRcE1 49.13 1248 24.75 629 25.13 638 8.88 226 1
Catalog
Number Series HWW/HD
Std.
Pack
IN mm IN mm IN mm IN mm
SAFETY SWITCHES
57
Double Throw Safety Switches
Fusible and Not Fusible
Class 3140
© 2004 Schneider Electric
All Rights Reserved
6/7/04
www.SquareD.com
For the most up-to-date information
For additional information, reference Catalog #3100CT9801.
New—Series F
30–100 A Types DT, DTU (Series F)
Fusible (DT) and not fusible (DTU) switches
available.
Manually operated switch suitable for use in
accordance with article 702 of the NEC,
ANSI/NFPA 70.
Standards: UL 98, NEMA KS1, CSA, and NOM
Modular design—switch handle, lock-plate, switch
mechanism, line and load bases are field
replaceable.
UL listed short circuit current ratings up to 200,000 A
(using Class R, J, or T fuses—see table for rating).
Load make/break rated.
Meets NEMA hp ratings.
Dual cover interlock.
May be padlocked ON or OFF.
Lock-off accepts up to three padlocks.
Side-opening door.
Quick make/quick break mechanism.
Meets NEMA requirements as heavy duty switch.
(Note: handle is all black)
Electrical interlock kits field installable.
Neutral assembly kits field installable (2 and 3-pole
switches).
UL Listed as suitable for use as service equipment.
Supplied as standard for switching one load between
two power sources, and may be field converted to
switch one power source between two loads.
30 (Series T4), 200–600 A Types 82,000,
92,000 and 200 A DTU (Series E)
Not fusible
Designed for manual transfer of loads from one
supply to another.
UL Listed switches are suitable for use in accordance
with Article 702 of the National Electrical Code,
ANSI/NFPA 70.
All 82,000–92,000 and DTU double throw switches
are continuous duty rated for their nameplate
ampere rating.
The 82,000 and DTU (Series E) switches are load
make/break rated.
The 92,000 switches are not load make/break rated
and should be used for isolating purposes only.
UL Listed as suitable for use as service equipment
except as footnoted.
Horsepower rated only as footnoted.
All accessories, except service ground kits, require
factory installation.
For application above 600 amperes, see
Supplemental Digest.
30–100 A DT, DTU (Series F5)
NEMA 1
DTU (Series E) 200 A
NEMA 3R
82,000 and 92,000 Line
NEMA 1
92251
SAFETY SWITCHES
www.SquareD.com
For the most up-to-date information
58
Double Throw Safety Switches
240 Volt
Class 3140
© 2004 Schneider Electric
All Rights Reserved
6/7/04
aRefer to page 6-35 for additional motor application data. The starting current of motors or more than standard horsepower may require the use of fuses with appropriate time delay characteristics.b
bIf used on corner grounded delta systems, install neutral and use outer switching pole for ungrounded conductors.b
cFor switching dc, use two switching poles..
dUse outer switching poles.
eMaximum rating.
f240 Vac onlyb
gHp rating applies only to H82454. (92454, 92454RB are not Hp rated)b
hNot UL listed or suitable for use as service equipment.b
iStd.—Using fast acting one time fuses. Max.—Using dual element time delay fuses.
jNeutral included with device.
System
Ampere
Rating
Current
Series
NEMA 1 NEMA 3R NEMA 4,4X,5
Stainless
NEMA 12
Gasketed
Horsepower Ratingsai
240 Vac
250 Vdc
c
Std. Max.
Catalog No. Price Catalog No. Price Catalog No. Price Catalog No. Price
Fusible
2-Pole, 240 Vac—250 Vdc
100 F DT223 $1586. DT223RB $2037. . . . . . . . . . . . . 7.5 15 b15 30 b20
3-Pole, 240 Vac—250 Vdc
30 F DT321 1097. DT321RB 1477. . . . . . . . . . . . . 1.5d3b3d7.5 b5
60 F DT322 1313. DT322RB 1741. . . . . . . . . . . . . 3d7.5 b10d15 b10
100 F DT323 2069. DT323RB 2483. . . . . . . . . . . . . 7.5d15 b15d30 b20
Not Fusible
2-Pole, 240 Vac—250 Vdc
60 F DTU222 $641. . . . . . . . . . . . . . . . . . . . . . . . . 10 . . . 10e
100 F DTU223 914. DTU223RB $898. . . . . . . . . . . . . . . . . . . 15 . . . 20e
30 T4 92251f390. . . . . . .. . .. . . . . . . . . . . . . . . . . . . . . . . .
200 E 82254 1210. DTU224NRB fj 1451. . . . . . . H82254 $3114. 15 . . . . . . . . . . . .
200 E 82254NW 1914. . . . . . .. . .. . . . . . . . . 15 . . . . . . . . . . . .
400 E 92255 f3548. 92255R f5251. . . . . . . H92255 f6259. . . . . . . . . . . . . . . .
3-Pole, 240 Vac—250 Vdc
30 F DTU321 536. . . . . . . . . . . . . . . . . . . . . . 3b5d10b5e
60 F DTU322 746. . . . . . . . . . . . . . . . . . . . . . . . . 10d15b10e
100 F DTU323 1176. DTU323RB 1302. . . . . . . . . . . . . . . . . . . 15d30b20e
30 T4 92351f458. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
200 E 82354f1709. DTU324NRBfj 2003. . . . . . . H82354f3605. . . . 15 . . . . . . . . .
200 E DTU324Nfj 1865. . . . . . .. . .. . . . . . . . . . . . 15 . . . . . . . . .
400 E 92355f4874. 92355Rf8692. . . . . . . H92355f7100. . . . . . . . . . . . . . . .
600 E 92356 c6605. 92356R f9081. . . . . . . H92356 9508. . . . . . . . . . . . . . . .
4-Pole, 240 Vac
30 T4 92451f635. . . . . . .. . .. . . . . . . . . . . . . . . . . . . . . . . .
200 E 92454 g2811. 92454RB g5011. . . . . . . H82454 g4519. . . . 15 g. . . . . . . . .
400 E 92455 6389. 92455R 9012. . . . . . . H92455 8860. . . . . . . . . . . . . . . .
600 E 92456 7683. 92456R 9904. . . . . . . H92456 h10641. . . . . . . . . . . . . . . .
Line
Line
Load
Line
Line
Load
Line
Line
Load
Line
Line
Load
DE1 Discount
Schedule
For additional information, reference Catalog #3100CT9801.
240 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 58
Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 59
Dimensions 30–100 A (Series F) . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 60
Dimensions 30, 200–600 A (Series E, T4) . . . . . . . . . . . . . . . . . . . . page 61
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 62
SAFETY SWITCHES
59
Double Throw Safety Switches
Application Data
Class 3140
© 2004 Schneider Electric
All Rights Reserved
6/7/04
www.SquareD.com
For the most up-to-date information
aRating applies to AC only. The UL Listed short circuit current rating for Not Fusible switches is based on the switch being used in conjunction with the
corresponding fuse type. Evaluation of Not Fusible switches in conjunction with molded case circuit breakers has not been performed.
bThe DTU361 and DTU361RB are also suitable for use on a circuit capable of delivering not more than
(A) 18,000 rms summetrical A, 600 Vac maximum when protected by Type FH circuit breaker rated 30 A maximum or
(B) 14,000 rms symmetrical A, 600 Vac maximum when protected by Type FA circuit breaker rated 30 A maximum.
cAny brand of circuit breaker or fuse not exceeding the ampere rating of the switch may be used ahead of an unfused safety switch when there is up to
10,000 A short circuit current available.
dThomas and Betts catalog numbers.
eVERSA-CRIMP® catalog numbers.
f200–600 A switches suitable for 75° C conductors.
g30 A switches suitable for 60° C or 75° C conductors.
UL Listed Short Circuit Current Ratings
Switch Type Ampere
Rating
Voltage
Rating
UL Listed
Fuse Class
Short Circuit
Current Ratinga
(RMS
Symmetrical
Amperes)
Type DT
(Series F) 30–100 A 240 V H, K 10,000
R, J 200,000
Type DTUb
(Series F) 30–100 A 240 V H or K 10,000c
R or J 200,000
DTU224NRB and
DTU324NRB
(Series E)
200 A 240 V H, K 10,000c
DTU324N
(Series E) 200 A 240 V H, K 10,000c
R, J 100,000
Type 82,000 all 240 V H, K 10,000c
R, J 100,000
600 V H, K 10,000c
Type 92,000 all 240 V H, K 10,000c
Terminal Lug Data for Type DT, DTU (Series F) Double Throw Safety Switches
Switch
Ampere
Rating
Wires
per
Phase
NEMA 1, 3R, 4, 4X, 12
Optional Copper Only Lug
Wire Range
Wire Bending
Space Per
NEC Table 373-6
AWG/kcmil
Al/Cu
Standard Lug
Wire Range
AWG/kcmil
Al/Cu
Optional
Compression Lug
Field Installable
30–60 A
Type DT, DTU
(Series F)
1
#12–2 (Al)
or
#14–2 (Cu)
#12–2 (Al)
or
#14–2 (Cu)
C10-14,
D8-14,
or E6-14dSee Digest 173 pages 3-11 and 3-13 for appropriate kit.
Order 2 kits per switch.
100 A
Type DT, DTU
(Series F)
1
#12–1/0 (Al)
or
#14–1/0 (Cu)
#12–1/0 (Al)
or
#14–1/0 (Cu)
VCEL02114S1e
Terminal Lug Data for Types 82,000, 92,000 and for E-Series DTU devicesf
Ampere
Rating
Wires
per
Phase
Wire Range
Wire Bending Space
Per NEC Table 373-6
AWG/kcmil
Al/Cu
Lug Wire Range
AWG/kcmil
Al/Cu
Optional
Compression Lugs
Field Installable
30 A (Series T4)g1#14–8
#12–2 (Al)
or
#14–2 (Cu)
. . .
200 1 #6–300 #6–300 VCEL030516H1e
400 2 #4–250 #4–350 . . .
600 2 #4–500 #4–600 . . .
Situations Requiring
Fuses:
30–100 A Type DT
(Series F):
Select DT switches from
page 58 which have
provisions for accepting
fuses.
30, 200–600 A Type
82,000, 92,000
(Series E, T4),
all DTU devices:
Use the not fused double
throw switches from
page 58 in conjunction
with standard fused
devices, and install them
according to the below
diagram 1 or 2.
Not-Fusible
D/T Switch
Line
Line
Load
Fusible
Single
Throw
Switch or
Circuit
Breaker
Not-Fusible
D/T Switch
Line
Line
Fusible
Single
Throw
Switch or
Circuit
Breaker
Fusible
Single
Throw
Switch or
Circuit
Breaker
Load
Diagram 1
Diagram 2
DE1 Discount
Schedule
For additional information, reference Catalog #3100CT9801.
240 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 58
Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 59
Dimensions 30–100 A (Series F) . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 60
Dimensions 30, 200–600 A (Series E, T4) . . . . . . . . . . . . . . . . . . . .page 61
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 62
SAFETY SWITCHES
www.SquareD.com
For the most up-to-date information
60
Double Throw Safety Switches
Dimensions—Series F Devices
Class 3140
© 2004 Schneider Electric
All Rights Reserved
6/7/04
30–100 A Type DT, DTU (Series F)—Approximate Dimensions
Catalog
Number Series HWW/HD
IN mm IN mm IN mm IN mm
DT223 F5 38.00 965 9.88 251 11.13 283 6.75 171
DT223RB F5 38.00 965 6.87 174 8.12 206 6.60 168
DT321 F5 38.00 965 10.25 260 11.50 292 6.75 171
DT321RB F5 38.00 965 10.25 260 11.80 300 6.60 168
DT322 F5 38.00 965 10.25 260 11.50 292 6.75 171
DT322RB F5 38.00 965 10.25 260 11.80 300 6.60 168
DT323 F5 38.00 965 9.88 251 11.13 283 6.75 171
DT323RB F5 38.00 965 6.87 174 8.12 206 6.60 168
DTU222 F5 29.94 760 10.25 260 11.96 304 6.93 176
DTU223 F5 29.94 760 10.25 260 11.96 304 6.93 176
DTU223RB F5 30.50 775 10.25 260 11.96 304 6.93 176
DTU321 F5 29.94 760 10.25 260 11.96 304 6.93 176
DTU322 F5 29.94 760 10.25 260 11.96 304 6.93 176
DTU323 F5 29.94 760 10.25 260 11.96 304 6.93 176
DTU323RB F5 30.50 775 10.25 260 11.96 304 6.93 176
W
W/H D
H
NEMA 1
W
W/H D
H
NEMA 3R
For additional information, reference Catalog #3100CT9801.
240 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 58
Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 59
Dimensions 30–100 A (Series F) . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 60
Dimensions 30, 200–600 A (Series E, T4) . . . . . . . . . . . . . . . . . . . . page 61
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 62
SAFETY SWITCHES
61
Double Throw Safety Switches
Dimensions—Series E, T4 Devices
Class 3140
© 2004 Schneider Electric
All Rights Reserved
6/7/04
www.SquareD.com
For the most up-to-date information
30, 200–600 A Types 82,000, 92,000 and E-Series DTU devices,
NEMA 1 and 3R—Approximate Dimensions
Catalog
Number Series HWW/HD
IN mm IN mm IN mm IN mm
DTU224NRB E1 32.50 826 20.63 524 24.00 610 10.63 270
DTU324N E1 32.50 826 23.50 597 26.85 682 10.63 270
DTU324NRB E1 32.50 826 24.13 613 26.25 667 10.63 270
82254 E1 30.88 784 15.75 400 19.63 499 9.75 248
82254NW E1 30.88 784 20.00 508 23.88 607 11.75 298
82354 E1 30.88 784 20.00 508 23.88 607 11.75 298
92251 T4 10.00 254 8.00 203 9.75 248 4.75 121
92255 E1 31.50 800 21.00 533 24.25 616 14.13 359
92255R E1 31.25 794 30.13 765 33.00 838 11.38 289
92351 T4 10.00 254 8.00 203 9.75 248 4.75 121
92355 E1 31.50 800 29.38 746 32.63 829 14.13 359
92355R E1 31.25 794 30.13 765 33.00 838 11.38 289
92356 E1 53.00 1346 34.25 870 37.50 953 16.38 416
92356R E1 52.63 1337 34.38 873 37.63 956 13.88 353
92451 T4 10.00 254 10.00 254 11.75 298 4.75 121
92454 E1 31.13 791 24.75 629 28.25 718 11.75 298
92454RB E1 30.78 782 20.50 521 28.00 711 10.62 270
92455 E1 31.50 800 37.75 959 41.13 1045 14.13 359
92455R E1 31.20 792 35.65 906 38.52 978 10.90 277
92456 E1 53.00 1346 44.25 1124 47.50 1207 16.38 416
92456R E1 52.50 1334 43.70 1110 48.00 1219 13.50 343
W
W/H
D
H
NEMA 1
W
H
D
W/H
DTU—200 A
NEMA 3R
For additional information, reference Catalog #3100CT9801.
240 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 58
Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 59
Dimensions 30–100 A (Series F) . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 60
Dimensions 30, 200–600 A (Series E, T4) . . . . . . . . . . . . . . . . . . . .page 61
Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 62
SAFETY SWITCHES
www.SquareD.com
For the most up-to-date information
62
Double Throw Safety Switches
Accessories
Class 3140
© 2004 Schneider Electric
All Rights Reserved
6/7/04
aFor Type 82,000 and 92,000 switches, neutral is available factory installed on 2 and 3-pole double throw switches.
Not UL Listed. To order, add suffix N to the standard catalog number and add the above price to the list price of the
switch. For DTU (Series E) switches, neutral is factory installed in standard device and is UL Listed.
bElectrical interlock kit catalog numbers with “1” suffix indicate one normally open and normally closed contact; “2”
indicates two normally open and two normally closed contacts. See Digest 173 page 3-9 for electrical interlock
ratings.
c30–100 A Type DT, DTU (Series F) switches contain (2) separate switching mechanisms. Each mechanism will
accept an electrical interlock. Some applications may therefore require (2) electrical interlocks.
d30–100A Type DT, DTU (Series F) switches with factory installed electrical interlocks installed are UL Listed and
interlocks are furnished with 2 N.O. /2 N.C. contacts installed in both “ON” positions. To order, add suffix EI to
standard catalog number.
eType 82,000 and 92,000, and DTU (Series E) switches are available with electrical interlock factory installed only.
Not UL Listed. Electrical interlocks are furnished with 2 N.O. /2 N.C. contacts and are installed in both “ON” positions.
To order, add suffix EI to standard catalog number.
Neutral Assembly For 2 and 3-Pole Switches Only
Switch
Ampere
Rating
Field Installed
Standard
Neutral Kit
Catalog No.
Terminal
Data
AWG/kcmil
Price
Field Installed
Copper only
Neutral Kit
Catalog No.
Terminal
Data
AWG/kcmil
Price
30–100 A
Type DT, DTU
(Series F)
SN0310 #14–1/0
Al/Cu $76. SN0310C #14–1/0
Cu $80.
30 A
(Series T4) aa605. . . . . . . . . .
200 A
Type 82000, 92,000
and DTU (Series E)
aa740. aa740.
400–600 A
Type 82000, 92,000 aa948. aa948.
Electrical Interlocks
Switch
Ampere
Rating
Field Installed
Electrical Interlock
Kit Catalog Numberb
Price
Factory Installed
Price Adder
Per Switch
30–100 A
Type DT, DTU
(series F)
EIK1, EIK2c$207. $603.d
200 A
Type 82000, 92,000
and DTU (series E)
. . . . . . 742.e
400–600 A
Type 82000, 92,000 . . . . . . 932. e
Class R Fuse Kits
When installed, this kit rejects all but Class R fuses. Kits
are available for field installation. For factory installation,
add “CLR” suffix to catalog number.
Lock-On Provisions—UL Listed
30–100 A type DT, DTU (Series F) and type 92,000
included on standard device.
Type 82,000 and 200 A DTU (Series E): available factory
installed. Add SPLO to catalog number and add $273. to
list price.
Service Grounding Kit (Required for service equipment use.)
Switch
Ampere
Rating
Field Installed
Service Ground Lug Kit
Catalog Number
Terminal
Data
AWG/kcmil
Price
30–100 A
Type DT, DTU
(Series F)
Included Included std.
30 A
Type 92,000 DT30SG (4) #14–4 Cu/Al $19.60
200 A
Type 82000, 92,000
and DTU (Series E)
DT100SG (3) #14–1/0 Cu/Al 20.00
400–600 A
Type 82000, 92,000
PKOGTA2
(2 required)
(4) #10–2/0 Cu or
(4) #6–2/0 Al 35.00
Switch
Ampere
Rating
Series
Number
Class R
Fuse Kit
Catalog
Number
Price
Factory
Installed
Price
Class R Fuse Kits—240 V (two kits per 3-pole switch)
30 F5 RFK03 $16.30 $260.00
60 F5 RFK06 17.00 260.00
100 F5 RFK10 31.80 260.00
Class R Fuse Kits—600 V (two kits per 3-pole switch)
30 F5 RFK06 17.00 260.00
60 F5 RFK06H 17.00 260.00
100 F5 RFK10 31.80 260.00
NEMA 3R rainproof enclosures with catalog number ending in RB have a bolt-on closing cap factory installed. Order bolt-on hubs separately from
table above. For more details see page 20. Hubs thru size 212 can be directly installed on RB devices. Devices requiring 3" or larger hubs must have
holes cut in the field. Gaskets are provided on 3" and larger hubs.
All hubs are UL Listed for indoor and rainproof applications and suitable for use with conduit having ANSI standard taper pipe thread.
Rainproof Bolt-On Hubs—For Use On NEMA 3R Enclosures
Conduit
Size 3411
1411222
1233
124Closing
Cap
Hub Cat. No. B075 B100 B125 B150 B200 B250 B300 B350 B400 BCAP
Price Each $23.30 $23.30 $23.30 $23.30 $42.90 $71.00 $130.00 $200.00 $245.00 $2.50
r
Watertight Hubs—For Use On NEMA 4, 4X and 5 Stainless Steel and NEMA 12 Enclosures
Conduit Trade Size 123411
1411222
1233
124
Standard-Zinc
Hub Catalog Number H050 H075 H100 H125 H150 H200 H250 H300 H350 H400
Zinc Price Each $20.70 $30.00 $31.40 $36.00 $55.00 $80.00 $ 92.00 $118.00 $188.00 $254.00
Chrome Plated
Hub Catalog Number H050CP H075CP H100CP H125CP H150CP H200CP H250CP H300CP H350CP H400CP
Chrome Plated Price Each 27.10 37.60 42.90 44.60 64.00 91.00 123.00 162.00 237.00 272.00
“RB Hub”
DE1 rDE1A Discount
Schedule
For additional information, reference Catalog #3100CT9801.
240 V Double Throw . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .page 58
Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 59
Dimensions 30–100 A (Series F) . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 60
Dimensions 30, 200–600 A (Series E, T4) . . . . . . . . . . . . . . . . . . . . page 61
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 62
63
Warranties
Square D Residential Products
© 2004 Schneider Electric
All Rights Reserved
6/7/04
A. Limited Warranties
1. Square D Single Phase Load Centers and Combination Service Entrance Devices. Square D warrants its single phase load
centers and combination service entrance devices to be free from defects in material and workmanship, under normal care and
proper usage in a residential installation, for a period of ten (10) years from the date of installation. If the product fails within the
warranty period because of a defect in material or workmanship, Square D will, at its option, repair or replace the defective part
or parts upon following the notice procedures below and return of product to place of purchase.
2. Square D Load Center Branch Circuit Breakers. Square D warrants its branch circuit breakers to be free from defects in material
and workmanship under normal care and proper usage in a residential installation, for the lifetime of the load center in which it is
installed. If the circuit breaker fails within the warranty period because of a defect in material or workmanship, Square D will
replace the defective breaker free of charge upon following the notice procedures below and return of the product to place of
purchase.
B. Exclusive Remedy — The repair and/or replacement of defective products is your sole and exclusive remedy.
C. Warranty Redemption and Exclusions —
1. Square D must be given prompt written notice of any defect or failure of any product covered by these limited warranties at the
following address: Square D Company, 1415 S. Roselle Road, Palatine, Illinois, 60067, (888) 778-2733, weekdays between the
hours of 8:00 a.m. and 5:00 p.m. Eastern Time.
For warranty redemption, you must return the product to Square D at the above address.
2. Any product returned under these limited warranties, if shipped, must be sent freight costs prepaid. Square D will deliver repaired
or replaced products to buyer, freight costs prepaid. Repaired or replaced products shall be warranted hereunder only for the
unexpired portion of the original warranty period. This warranty does not include costs or reimbursement for labor.
Any limited warranties granted or liabilities assumed hereunder will not apply to products that have been damaged, altered,
repaired or operated otherwise than in conformity with the requirements for safe operation and maintenance.
For your safety and to provide optimum short circuit protection, Square D recommends that you use only the Square D circuit
breakers identified on the load center or combination service entrance device label or wiring diagram. Square D disclaims all
liability for damage, injury or non-performance caused by the use or failure of incompatible or UL Classified circuit breakers.
D. Disclaimer of All Other Warranties — EXCEPT FOR THE EXPRESS WARRANTY SET FORTH ABOVE OR ANY WARRANTIES
IMPLIED BY LAW, Square D MAKES NO OTHER EXPRESS OR IMPLIED WARRANTIES. TO THE FULLEST EXTENT
PERMITTED BY LAW, Square D DISCLAIMS ALL IMPLIED WARRANTIES, INCLUDING ALL WARRANTIES OF
MERCHANTABILITY AND/OR FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING DISCLAIMER MAY NOT APPLY
TO YOU DEPENDING UPON THE PRODUCT YOU PURCHASE, THE APPLICATION AND USE OF YOUR PRODUCT, OR YOUR
STATUS AS A CONSUMER. TO THE EXTENT YOU ARE ENTITLED TO RECOVER UNDER AN IMPLIED WARRANTY, THE
DURATION OF THAT IMPLIED WARRANTY SHALL BE THE PERIOD OF THE EXPRESS LIMITED WARRANTY SET FORTH
ABOVE.
E. Limitation of Liability — Square D expressly disclaims any and all liability to you for any consequential or incidental damages,
damages for loss of use, loss of profits, income or revenue, loss of time or inconvenience, loss or damage to associated equipment,
damages to tangible or intangible property, other than the equipment covered by this limited warranty, cost of substituted or
replacement equipment other than as expressly warranted, damages associated with excessive overvoltages, obsolescence,
abuse, misuse, non-authorized modification, alteration or catastrophic events, or any other incidental, consequential or special
damage arising out of the use of the products. Square D shall not be liable for indirect, special, incidental or consequential damages
with respect to the sale of the products, including any lost revenue or profits, consequential and/or incidental damages, business
interruption or damage to business reputation, regardless of the theory upon which any claim may be based, including any statutory,
tort contract or insurance subrogation causes of action or claims. In no event will Square D’s entire liability to you, including any
liability in the event the exclusive remedy set forth in this agreement fails of its essential purpose, exceed the purchase price for the
affected products. Some States do not allow the exclusion or limitation of incidental or consequential damages, so the preceding
limitations or exclusions may not apply to you. This limited warranty gives you specific legal rights, and you may also have other
rights which vary from State to State.
64
Warranties
Square D Structured Wiring
© 2004 Schneider Electric
All Rights Reserved
6/7/04
A. Limited Warranty — Square D warrants to customers purchasing through authorized Square D distributors that the Square D®
labeled passive (enclosure, cover and any non-powered module) structured wiring products (“passive components”) at the time of
sale by Square D are free from defects in materials and workmanship. Square D also warrants that the Square D labeled active (any
powered module) structured wiring products (“active components”) at the time of sale by Square D are free from defects in materials
and workmanship.
B. Exclusions and Exclusive Remedy —
If within the applicable warranty period, purchaser discovers that a product subject to this Limited Warranty was not as warranted
and promptly notifies Square D in writing, Square D shall repair or replace the product or refund the purchase price, at Square D’s
option. This warranty shall not apply (a) to equipment not supplied by Square D, (b) to equipment or product which shall have been
improperly repaired or altered or modified in a non-authorized manner, (c) to equipment or products which shall have been subjected
to negligence, misuse, accident, or damage by circumstances beyond Square D’s control, or to improper operation, maintenance
or storage, or to other than normal use or service. The foregoing limited warranties do not cover reimbursement for labor,
transportation, removal, installation, or other expenses that may be incurred in connection with repair or replacement. This Limited
Warranty is your sole and exclusive remedy.
C. Warranty Period — For active components, this Limited Warranty shall be in effect until five (5) years following the date of purchase,
or until four (4) years following the house closing by the original owner. For passive components, this Limited Warranty shall be in
effect until fifteen (15) years following the date of purchase, or until fourteen (14) years following the house closing by the original
owner.
D. Warranty Transferable — The unexpired portion of this warranty can be transferred to the subsequent homeowner.
E. Claims Procedure — Send either (1) the original dated sales receipts of the product or
(2) the dated documentation of the original owner’s house closing or (3) original Certificate
of Occupancy along with the damaged product
to Square D Company, 8001 Highway 64 East, Knightdale, NC 27545, Attn: Multi-Link Device Warranty.
Note: If these documents are unavailable, the product may be returned to the address above, and the earliest identifiable date code
stamped on the product will be used to determine if the product is subject to the conditions and terms of this express warranty.
F. Disclaimer of All Other Warranties — EXCEPT FOR THE EXPRESS WARRANTY SET FORTH ABOVE OR ANY WARRANTIES
IMPLIED BY LAW, Square D MAKES NO OTHER EXPRESS OR IMPLIED WARRANTIES. TO THE FULLEST EXTENT
PERMITTED BY LAW, Square D DISCLAIMS ALL IMPLIED WARRANTIES, INCLUDING ALL WARRANTIES OF
MERCHANTABILITY AND/OR FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING DISCLAIMER MAY NOT APPLY
TO YOU DEPENDING UPON THE PRODUCT YOU PURCHASE, THE APPLICATION AND USE OF YOUR PRODUCT, OR YOUR
STATUS AS A CONSUMER. TO THE EXTENT YOU ARE ENTITLED TO RECOVER UNDER AN IMPLIED WARRANTY, THE
DURATION OF THAT IMPLIED WARRANTY SHALL BE THE PERIOD OF THE EXPRESS LIMITED WARRANTY SET FORTH
ABOVE.
G. Limitation of Liability — Square D expressly disclaims any and all liability to you for any consequential or incidental damages,
damages for loss of use, loss of profits, income or revenue, loss of time or inconvenience, loss or damage to associated equipment,
damages to tangible or intangible property, other than the equipment covered by this limited warranty, cost of substituted or
replacement equipment other than as expressly warranted, damages associated with excessive overvoltages, obsolescence,
abuse, misuse, non-authorized modification, alteration or catastrophic events, or any other incidental, consequential or special
damage arising out of the use of the products. Square D shall not be liable for indirect, special, incidental or consequential damages
with respect to the sale of the products, including any lost revenue or profits, consequential and/or incidental damages, business
interruption or damage to business reputation, regardless of the theory upon which any claim may be based, including any statutory,
tort contract or insurance subrogation causes of action or claims. In no event will Square D’s entire liability to you, including any
liability in the event the exclusive remedy set forth in this agreement fails of its essential purpose, exceed the purchase price for the
affected products. Some States do not allow the exclusion or limitation of incidental or consequential damages, so the preceding
limitations or exclusions may not apply to you. This limited warranty gives you specific legal rights, and you may also have other
rights, which vary from State to State.
Square D Conditions Of Sale
© 2004 Schneider Electric
All Rights Reserved
6/7/04
1. GOVERNING PROVISIONS AND ACCEPTANCE: All
quotations are subject to these conditions of sale.
Acceptance of an order by Square D shall be expressly
conditioned on Purchaser’s assent to these conditions.
Purchaser’s direction to proceed with engineering,
manufacture or shipment by Square D shall be deemed
evidence of this assent. No modified or other conditions will
be applicable unless those conditions are so stated in
Square D’s proposal or are specifically agreed to in writing
and signed by an authorized official of Square D. Failure to
object to provisions contained in any Purchase Order or
other communication from the Purchaser (including, without
limitation, penalty clauses of any kind) shall not be
construed as a waiver of these Conditions nor an
acceptance of any other provisions. These terms are a
complete statement of the parties’ agreement and may only
be modified in writing signed by both parties. These terms
may not be modified by course of dealing, course of
performance or usage of trade. These terms supersede all
previous written or oral quotations, statements or
agreements. Any contract for sale by and between the
parties shall be governed by and construed according to
the laws of the State of Illinois without regard to its rules on
the conflict of laws. The Convention on the International
Sale of Goods is expressly excluded.
2. QUOTATIONS: Written quotations shall be valid for no
more than thirty (30) days from their date, unless otherwise
stated in the quotation. All quotations are subject to change
by Square D Company at any time upon notice to
Purchaser. It is Purchaser’s obligation to review the
quotation carefully and to immediately advise Square D in
writing of any differing interpretation Purchaser has so any
necessary change can be made.
3. PRICE POLICY: All prices are subject to change without
notice. In the event of a net price change and unless
otherwise agreed to in writing, prices for orders scheduled
for immediate release shall be those in effect at time of
order entry. Prices for orders placed for future shipment
without an agreed price and ship date will be billed at the
pricing in effect as of the shipment date. All clerical errors
are subject to correction.
4. SUBSTITUTION: Square D may furnish suitable
substitutes for material unobtainable because of priorities or
regulations established by governmental authority or non-
availability of materials from suppliers, provided such
substitutions do not adversely affect the technical
soundness of the equipment. Square D assumes no liability
for deviation from published dimensions and descriptive
information not essential to proper performance of the
product.
5. TAXES: Any manufacturer’s tax, retailer’s tax, occupation
tax, use tax, sales tax, excise tax, (except federal excise tax
on vehicles), duty, customs, inspecting or testing fee, or
other tax, fee or charge of any nature whatsoever, imposed
by any governmental authority or measured by any
transaction between Square D and Purchaser, shall be paid
by the Purchaser in addition to the prices quoted or
invoiced, and such charges will appear as a separate line
item on the invoice. In the event Square D will be required
to pay any such tax, fee, or charge, Purchaser shall
reimburse Square D or, in lieu of such payment, Purchaser
shall supply Square D at the time the order is submitted
with an exemption certificate or other document acceptable
to the tax authority. Purchase Orders must state the
existence and amount of any such tax, fee or charge for
which Purchaser claims an exemption.
6. TERMS OF PAYMENT: Acceptance of all Purchase Orders
is subject to Purchaser meeting Square D credit standards.
Te r ms are subject to change for failure to meet such
standards. Terms are net thirty (30) days from date of
invoice of each shipment, unless otherwise stated in
Square D’s quotation. For an authorized distributor or
authorized reseller order, applicable terms of payment are
stated in the quotation or applicable discount schedule.
Square D reserves the right at any time to demand full or
partial payment before proceeding with a contract of sale if,
in its sole judgment, as a result of changes in the financial
condition of the Purchaser the terms of payment originally
specified are no longer justified.
7. PAYMENTS: If delivery is delayed or deferred by the
Purchaser beyond the scheduled date, payment shall be
due in full when Square D is prepared to ship. The
equipment may be stored at the risk and expense of the
Purchaser. If the Purchaser defaults when any payment is
due, then the whole contract price shall become due and
payable upon demand, or Square D at its option, without
prejudice to other lawful remedies, may defer delivery or
cancel the contract for sale. If Purchaser becomes
insolvent, or bankrupt or in the event any proceeding is
brought against the Purchaser, voluntarily or involuntarily
under the bankruptcy or any insolvency law, Square D may
cancel any order outstanding at any time and recover its
applicable cancellation charges from the Purchaser or the
Purchaser’s estate.
8. DELIVERY:
A) F.O.B. POINT OF SHIPMENT: When the Square D
quotation is based on delivery F.O.B. point of shipment,
freight prepaid and allowed for delivery within the
continental United States, product is sold F.O.B. point of
shipment, freight prepaid and allowed. A shipping and
handling charge of twenty-five dollars ($25) will be
added to all orders having a total net invoice price of
less than one thousand dollars ($1,000). Delivery by
Square D to the point of shipment constitutes delivery
to the Purchaser; and title and all risk of loss or damage
NOTE: The following Conditions of Sale are subject to change. All transactions for all products sold by Square D
Company, including Square D brand products and all Schneider Electric brand products, such as Merlin Gerin,
Modicon and Telemecanique brand products, are subject to the latest published Conditions of Sale of the
Square D Company and to any Special Conditions of Sale which may be contained in applicable Square D
quotations and acknowledgments.
(Continued)
Square D Conditions Of Sale
© 2004 Schneider Electric
All Rights Reserved
6/7/04
in transit shall pass to the Purchaser at time of delivery
at the F.O.B. point. Square D is not responsible for
breakage after having received “in good order” receipts
from the carrier. Purchaser is responsible for pursuing
any damage claims with the carrier. No allowance will
be made in lieu of transportation if the Purchaser
accepts shipment at factory, warehouse or freight
station or otherwise supplies its own transportation.
Freight prepaid is defined as: a) Shipments to
destinations within the continental United States to the
accessible common carrier point nearest the first
destination. b) Shipments to U.S. destinations outside
the continental United States shall be to the common
carrier free delivery point in the United States nearest
the original port of embarkation. All charges associated
with F.A.S., C.I.F., or other charges such as pier
transfer, lift, ocean freight, and marine or war insurance
shall be paid by the Purchaser, unless otherwise
specifically agreed in a specific Purchase Order. In no
event will Square D be responsible for demurrage or
detention charges.
B) DELIVERY: F.O.B. DESTINATION: When the
Square D quotation is based on delivery F.O.B.
Destination, for shipments for delivery within the
continental United States, Square D will retain title and
all risk of loss or damage in transit to the common
carrier free delivery point in the United States nearest
the first destination for a price addition of 2% of the net
price. If the Purchaser elects this option, Purchaser’s
obligations shall be as follows: a) Purchaser shall
have the responsibility of inspecting the equipment for
apparent loss or damage immediately upon its arrival at
the free delivery point. b) In the event of apparent
shipping loss or damage, Purchaser shall make written
notation of the loss on the carrier’s delivery receipt and,
within 72 hours of delivery shall notify the Square D
Customer Information Center. Purchaser shall not
remove product from the point of examination and shall
retain the shipping container and packing material.
Purchaser shall request the carrier to make an
inspection and send Square D a copy of the carrier’s
inspection report. c) In the event of concealed damage
which occurred during transit and is discovered by the
Purchaser after delivery, Purchaser shall report such
damage immediately, but in no event later than 15 days
after delivery, to the delivering carrier, and within 72
hours of discovery, shall notify the local Square D field
office. If such notification is not made, Square D shall
not be liable for loss or damage in transit.
C) SHIPMENT AND ROUTING: Square D shall select the
point of origin of shipment, the method of transportation
and the routing of the shipment. Purchasers that
request expedited or special modes of transportation or
routing involving air, premium or any other non-
standard Square D shipping shall be assessed
additional charges for shipping, handling, freight and
expediting. Any rebates, allowances, discounts or
incentives received by Square D from its carriers shall
be retained by Square D. All prices include domestic
packaging only. When other than domestic packaging is
required, contact your local Square D field office.
Purchaser specified packaging and marking may be
subject to additional charges.
9. SHORTAGES: Claims for shortages or errors must be
made in writing to Square D within 60 days after invoice
date, and failure to give such notice shall constitute
unqualified acceptance and a waiver of all such claims by
the Purchaser.
10. INSTALLMENTS: Square D reserves the right to make
shipments in installments, unless otherwise expressly
stipulated in a specific Purchase Order; and all such
installments when separately invoiced shall be paid for
when due per invoice without regard to subsequent
shipments. Delay in shipment of any installment shall not
relieve Purchaser of its obligation to accept remaining
shipments.
11. FORCE MAJEURE: Square D shall not be liable for any
damages as a result of any delays due to any causes
beyond Square D’s control, including, without limitation, an
act of God; act of Purchaser or Square D supplier; embargo
or other governmental act; regulation or request; fire;
accident; strike; slowdown; flood; fuel or energy shortage;
sabotage; war; riot; delay in transportation and inability to
obtain necessary labor, materials or manufacturing facilities
from usual sources. In the event of any such delay, the date
of delivery shall be extended for a period of time reasonably
necessary to overcome the effect of such delay.
12. STANDARD WARRANTY: Square D warrants equipment
manufactured by it and sold through authorized sales
channels to be free from defects in materials and
workmanship for eighteen (18) months from date of invoice
by Square D or its authorized sales channel. If within such
period any such equipment shall be proved to Square D’s
satisfaction to be non-conforming, such equipment shall be
repaired or replaced at Square D’s option. This warranty
shall not apply (a) to equipment not manufactured by
Square D, (b) to equipment that has been repaired or
altered by other than Square D so as, in its judgment, to
affect the same adversely, or (c) to equipment that has
been subjected to negligence, accident, or damage by
circumstances beyond Square D’s control, or improper
operation, maintenance or storage, or to other than normal
use or service. With respect to equipment not manufactured
by Square D, the warranty obligations of Square D shall in
all respects conform and be limited to the warranty actually
extended to Square D by its supplier. Non-conforming
products must be returned at Square D’s expense for
evaluation unless this is waived in writing. Replacement
products may be new or reconditioned. The foregoing
warranties do not cover reimbursement for labor,
transportation, removal, installation, temporary power, or
any other expenses that may be incurred in connection with
repair or replacement.
13. OPTIONAL WARRANTIES: (Only available on equipment
to be located in the U.S.) Option 1—Extended—2 or 3
years from Shipment. If requested by the Purchaser and
specifically accepted in writing by Square D, the standard
(Continued)
Square D Conditions Of Sale
© 2004 Schneider Electric
All Rights Reserved
6/7/04
warranty will be extended to two (2) years from date of
invoice for a price addition of 1% of the net face value of the
Purchase Order or will be extended for three (3) years from
date of invoice for a price addition of 3% of the net face
value of the Purchase Order. Option 2—Special
Warranty: If requested by the Purchaser and specifically
accepted in writing by Square D, the standard warranty will
be extended, for a price addition of 3% of the net face value
of the Purchase Order, to cover reimbursement of the direct
costs of: a) Removal of non-conforming equipment or part
thereof; b) Transporting equipment or parts to and from the
place of repair; c) Off-loading of truck and reinstallation at
the original site. Such special warranty, which may be
chosen to cover a period not exceeding that of the standard
or extended warranty (see above) selected, will not include
the cost of providing temporary power or removing or
replacing other apparatus or structures, or costs of
transportation beyond a common carrier free delivery point
in the continental United States. Further, the obligation of
Square D for expenses and costs arising under this special
warranty coverage will not exceed 50% of the net invoice
price on the equipment being repaired. This warranty does
not change or affect the allocation of risk or loss during
shipment. Option 3—Extended Warranty—Preventative
Maintenance Agreements: If requested by the Purchaser,
and specifically accepted by Square D, a Preventative
Maintenance Agreement is available to provide preventative
maintenance on equipment covered by the agreement.
Te r ms of the Preventative Maintenance Agreement shall be
as defined in a separate Services Agreement agreed to by
the parties.
14. RETURN OF EQUIPMENT: NO EQUIPMENT MAY BE
RETURNED WITHOUT FIRST OBTAINING SQUARE D’S
WRITTEN PERMISSION AND A RETURNED MATERIAL
IDENTIFICATION TAG. Returned equipment must be of
current manufacture, in the original packaging, unused,
undamaged and in saleable condition. Returned equipment
must be securely packed to reach Square D without
damage and labeled with the return authorization number.
Any cost incurred by Square D to put equipment in first
class condition will be charged to the Purchaser. Purchaser
requested returns not involving a Square D error will be
assessed Square D's standard restocking fee. Returns will
be credited at the pricing specified in Square D's standard
return policy. Special Order and Custom equipment is not
returnable. Square D shall bear the cost of returns resulting
from Square D error, and method and route of return will be
at the discretion of Square D. Costs incurred by failure to
follow Square D direction will be borne by the Purchaser.
15. SOFTWARE: Any software or computer information, in
whatever form that is provided with equipment
manufactured by Square D, is licensed to Purchaser solely
pursuant to standard licenses of Square D or its supplier of
such software or computer information which licenses are
hereby incorporated by reference. Square D does not
warrant that such software or computer information will
operate error free or without interruption, and warrants only
that during the warranty period applicable to the equipment
that the software will perform the essential functions
necessary for the normal and customary operation of the
equipment. If such software or computer information fails to
conform to such warranty, Square D will, at its option,
provide an update to correct the non-conformance or
replace the software or computer information with the latest
available version containing a correction. Square D shall
have no obligation to provide updates or revisions.
16. LIMITATIONS: These disclaimers and limitations of
remedies apply to all warranties offered to Purchaser and
to all Purchase Orders. THE WARRANTIES SET FORTH
ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER
EXPRESSED OR IMPLIED WARRANTIES (EXCEPT
WARRANTIES OF TITLE), INCLUDING, BUT NOT
LIMITED TO IMPLIED WARRANTIES OF MERCHANT-
ABILITY AND FITNESS FOR A PARTICULAR PURPOSE.
Except as may be expressly provided in an authorized
writing by Square D, Square D shall not be subject to any
other obligations or liabilities whatsoever, other than as
stated above with respect to equipment sold or services
rendered by Square D. Notwithstanding anything to the
contrary herein contained SQUARE D COMPANY, ITS
CONTRACTORS AND SUPPLIERS OF ANY TIER,
SHALL NOT BE LIABLE IN CONTRACT, IN TORT
(INCLUDING NEGLIGENCE OR STRICT LIABILITY) OR
OTHERWISE FOR LOST TIME, LOST PROFITS, OR
SPECIAL, INDIRECT, INCIDENTAL OR CON-
SEQUENTIAL DAMAGES OF ANY KIND WHATSOEVER.
The remedies of the Purchaser are exclusive and the total
cumulative liability of Square D, its contractors and
suppliers of any tier, with respect to this contract or anything
done in connection therewith, such as the use of any
product covered by or furnished under the contract,
whether in contract, in tort (including negligence or strict
liability) or otherwise, shall not exceed the price of the
product, part, or service on which such liability is based.
17. INTELLECTUAL PROPERTY: As to equipment proposed
and furnished by Square D, Square D shall defend any suit
or proceeding brought against Purchaser so far as based
on a claim that such equipment constitutes an infringement
of any copyright, trademark or patent of the United States.
This obligation shall be effective only if Purchaser shall
have made all payments then due hereunder and if
Square D is notified promptly in writing and given authority,
information, and assistance at Square D’s expense for the
defense of the same. In the event the use of such
equipment by Purchaser is enjoined in such a suit,
Square D shall, at its expense, and at its sole option, either
(a) procure for the Purchaser the right to continue using
such equipment (b) modify such equipment to render it
non-infringing (c) replace such equipment with non-
infringing equipment, or (d) refund the purchase price (less
depreciation) and the transportation and installation costs
of such equipment. Square D will not be responsible for any
compromise or settlement made without its written consent.
The foregoing states the entire liability of Square D for
patent, trademark or copyright infringement, and in no
event shall Square D be liable if any infringement charge is
based on the use of Square D equipment for a purpose
other than that for which it was sold by Square D. As to any
(Continued)
Square D Conditions Of Sale
© 2004 Schneider Electric
All Rights Reserved
6/7/04
equipment furnished by Square D to Purchaser and
manufactured in accordance with designs proposed by
Purchaser, the Purchaser shall indemnify Square D against
any award made against Square D for patent, trademark, or
copyright infringements.
18. WITNESS OF TESTS AND FACTORY INSPECTIONS:
Normal production schedules do not provide the
opportunity for Purchaser to witness routine factory tests on
equipment or make factory inspections. Witnessing of
tests or factory inspections by the Purchaser may
result in delays of production for which Square D will
not be responsible. Witness testing and factory
inspections must be requested at time of quotation, are
subject to additional costs and must be confirmed at
order entry. Standard Square D factory testing and
inspection will apply. Square D will notify Purchaser
fourteen (14) calendar days prior to scheduled witness
testing or inspection. In the event Purchaser is unable to
attend, the Parties may mutually agree on a rescheduled
date. However, Square D, at its sole option, may consider
the witness tests and/or inspection waived, and ship and
invoice the Products and the witness testing charges.
Purchaser will be responsible for paying for all scheduled
witness testing, whether or not Purchaser attends.
19. NUCLEAR APPLICATIONS TERMS AND CONDITIONS:
Unless otherwise agreed in writing by a duly authorized
representative of Square D, products sold hereunder are
not intended for use in or in connection with any nuclear
facility or activity. If so used, Square D disclaims all liability
for any damage, injury or contamination arising from a
nuclear incident or nuclear hazard; and Purchaser shall
indemnify Square D against any such liability, whether
arising as a result of breach of contract, warranty or tort
(including negligence) or otherwise.
20. PATTERNS AND TOOLS: Notice will be given if special
patterns or tools are required to complete any order.
Charges for such patterns or tools do not convey title
thereto or the right to remove them from Square D’s plant. If
patterns or tools are not used for a period of two years,
Square D shall have the right to scrap them without notice.
21. PRODUCT NOTICES: Purchaser shall promptly supply the
user (including its employees) of the product with all
Square D supplied product notices, warnings, instructions,
recommendations and similar materials.
22. ERRORS: Square D reserves the right to correct errors or
omissions in quotations, acknowledgments, invoices, or
other documents.
23. OSHA COMPLIANCE: Compliance with OSHA or similar
federal, state or local laws during the operation or use of the
product(s) is the sole responsibility of the Purchaser.
24. TERMINATION: Any order may be terminated by the
Purchaser only upon written notice to Square D and upon
payment of reasonable and proper termination charges
based on the price of the terminated order and
reimbursement of all direct costs and expenses associated
with the order caused by such termination and shall include
a reasonable profit. Special or custom ordered equipment
is not cancelable after final acceptance of approval
drawings for the commencement of manufacturing.
25. CANCELLATION: Square D shall have the right to cancel
any order or contract at any time by written notice for any
material breach of the contract by the Purchaser, including
material delays in releasing equipment for manufacture or
approval drawings and excessive changes to specifications
or drawings.
FRACTIONS TO DECIMALS TO MILLIMETERS
Fractions Decimals Millimeters
1/64 0.015625 0.397
1/32 0.03125 0.794
3/64 0.046875 1.191
1/16 0.0625 1.588
5/64 0.078125 1.984
3/32 0.09375 2.381
7/64 0.109375 2.778
1/8 0.1250 3.175
9/64 0.140625 3.572
5/32 0.15625 3.969
11/64 0.171875 4.366
3/16 0.1875 4.763
13/64 0.203125 5.159
7/32 0.21875 5.556
15/64 0.234375 5.953
1/4 0.2500 6.350
17/64 0.265625 6.747
9/32 0.28125 7.144
19/64 0.296875 7.541
5/16 0.3125 7.938
21/64 0.328125 8.334
11/32 0.34375 8.731
23/64 0.359375 9.128
3/8 0.3750 9.525
25/64 0.390625 9.922
13/32 0.40625 10.319
27/64 0.421875 10.716
7/16 0.4375 11.113
29/64 0.453125 11.509
15/32 0.46875 11.906
31/64 0.484375 12.303
1/2 0.500 12.700
33/64 0.515625 13.097
17/32 0.53125 13.494
35/64 0.546875 13.891
9/16 0.5625 14.288
37/64 0.578125 14.684
19/32 0.59375 15.081
39/64 0.609375 15.478
5/8 0.6250 15.875
41/64 0.640625 16.272
21/32 0.65625 16.669
43/64 0.671875 17.066
11/16 0.6875 17.463
45/64 0.703125 17.859
23/32 0.71875 18.256
47/64 0.734375 18.653
3/4 0.7500 19.050
49/64 0.765625 19.447
25/32 0.78125 19.844
51/64 0.796875 20.241
13/16 0.8125 20.638
53/64 0.828125 21.034
27/32 0.84375 21.431
55/64 0.859375 21.828
7/8 0.8750 22.225
57/64 0.890625 22.622
29/32 0.90625 23.019
59/64 0.921875 23.416
15/16 0.9375 23.813
61/64 0.953125 24.209
31/32 0.96875 24.606
63/64 0.984375 25.003
1 1.000 25.400
MILLIMETERS TO INCHES
Millimeters Inches Millimeters Inches
0.1 0.0039 46 1.8110
0.2 0.0079 47 1.8504
0.3 0.0118 48 1.8898
0.4 0.0157 49 1.9291
0.5 0.0197 50 1.9685
0.6 0.0236 51 2.0079
0.7 0.0276 52 2.0472
0.8 0.0315 53 2.0866
0.9 0.0354 54 2.1260
55 2.1654
1 0.0394 56 2.2047
2 0.0787 57 2.2441
3 0.1181 58 2.2835
4 0.1575 59 2.3228
5 0.1969 60 2.3622
6 0.2362 61 2.4016
7 0.2756 62 2.4409
8 0.3150 63 2.4803
9 0.3543 64 2.5197
10 0.3937 65 2.5591
11 0.4331 66 2.5984
12 0.4724 67 2.6378
13 0.5118 68 2.6772
14 0.5512 69 2.7165
15 0.5906 70 2.7559
16 0.6299 71 2.7953
17 0.6693 72 2.8346
18 0.7087 73 2.8740
19 0.7480 74 2.9134
20 0.7874 75 2.9528
21 0.8268 76 2.9921
22 0.8661 77 3.0315
23 0.9055 78 3.0709
24 0.9449 79 3.1102
25 0.9843 80 3.1496
26 1.0236 81 3.1890
27 1.0630 82 3.2283
28 1.1024 83 3.2677
29 1.1417 84 3.3071
30 1.1811 85 3.3465
31 1.2205 86 3.3858
32 1.2598 87 3.4252
33 1.2992 88 3.4646
34 1.3386 89 3.5039
35 1.3780 90 3.5433
36 1.4173 91 3.5827
37 1.4567 92 3.6220
38 1.4961 93 3.6614
39 1.5354 94 3.7008
40 1.5748 95 3.7402
41 1.6142 96 3.7795
42 1.6535 97 3.8189
43 1.6929 98 3.8583
44 1.7323 99 3.8976
45 1.7717 100 3.9370
FRACTION, DECIMAL, AND MILLIMETER EQUIVALENTS
CONVERSION TABLES
0110PL9401R5/04 (Replaces 0110PL9401R11/01) 5-04
Schneider Electric North American Operating Division
1415 S. Roselle Road
Palatine, IL 60067
Tel: 847-397-2600
Fax: 847-925-7500
©2004 Schneider Electric. All rights reserved.
Customer
INFORMATION CENTER
One toll-free number to call to get all the information you need.
The Square D Customer Information Center (CIC) is the single point of
contact where qualified personnel answer your customer service and
technical support questions.
Serving all Square D authorized distributors and customers in the U.S.
Technology
WITHOUT BOUNDARIES
The Square D Multi-Link Structured Wiring System....
a complete network solution
The Square D Multi-Link System provides a complete network solution
designed to make life more mobile, more flexible, and more convenient.
Providing voice, data and video connectivity throughout the home, the
Multi-Link System allows you to share entertainment equipment, monitor areas
of the home, and exchange data through a series of connected networks.
WWW.SQUARED.COM
For all of your current selection and specification
information needs
DigestPlus SelectorTM is the most advanced product selection tool in the
industry. This intuitive, on-line selection tool will add value to your business
by simplifying your design, specifying and purchasing processes.
Product Categories - browse by product
Alphabetical Listing - browse by product
Search - by text or catalog number
Merchandise Product Selector - select by characteristics
With access to all of the most up-to-date technical documentation and
merchandise drawings to support your design and specification requirements,
the Square D website is a virtual workzone.
The shopping cart feature will save you time by allowing you to print to your
laser printer or e-mail to your Square D distributor.
Monday-Friday 8:00 a.m. - 8:00 p.m. EST
1-888-SQUARED
(1-888-778-2733)

Navigation menu