Product Detail Manual
2014-09-05
: Pdf 102168-Attachment 102168-Attachment 786849 Batch7 unilog
Open the PDF directly: View PDF .
Page Count: 147
Download | |
Open PDF In Browser | View PDF |
Metering Products Group Metering and Meter Breaker Family 5.1 Single Meter Sockets Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.2 5.4 5.7 5.10 V1-T5-29 V1-T5-34 V1-T5-35 V1-T5-37 V1-T5-39 V1-T5-48 V1-T5-59 V1-T5-65 V1-T5-75 V1-T5-83 V1-T5-86 V1-T5-87 Group Metering Systems for Residential and Commercial Applications . . . . . . . . . . . . Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type CCV 120/240V Tenant Main Circuit Breaker . . . . . . . . . . . . . . . . Type CV 120/240V Tenant Main Circuit Breaker . . . . . . . . . . . . . . . . . Meter Packs—1MP, 1MM and 3MM Main Tenant Circuit Breakers . . Main Service Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Surge Metering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Residential Meter Stacks. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1MP, 1MM and 3MM Main Tenant Circuit Breakers . . . . . . . . . . . . . . Phase Balanced Stack . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Commercial Meter Stack Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . 35MM, 37MM, 35SS and 37SS Main Tenant Circuit Breakers . . . . . . 5 5 5 5 5 Meter Breakers Residential Meter Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Non-EUSERC Combination Service Entrance Devices 100–200A Styles Meets EUSERC Requirements Service Entrance Devices 100–225A. West Coast All-In-One Design. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Mechanical Interlock Cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . House Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Commercial Safety Sockets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . CH Style Renovation Solutions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Aluminum Meter Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 5 Communications Grounding Device (NEC 250.94) Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.9 V1-T5-27 Mechanical Lugs Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.8 V1-T5-25 Accessories and Cross-Reference Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 5 Residential Pedestals Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.6 V1-T5-18 Instrument Rated Sockets Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.5 V1-T5-10 Multiple Position Horizontal Ganged Sockets Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 5 Commercial Lever Bypass Sockets Product Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5.3 V1-T5-2 V1-T5-88 V1-T5-90 V1-T5-95 V1-T5-96 V1-T5-98 V1-T5-101 V1-T5-115 V1-T5-116 V1-T5-125 V1-T5-126 V1-T5-127 V1-T5-134 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Learn Online 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-1 5.1 5 Metering Products Single Meter Sockets Contents Single Meter Sockets Description 5 Features and Benefits . . . . . . . . . . . . . . . . . . . . . . Catalog Number Selection . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Product Description Single-Phase Three-Wire and Three-Phase Four-Wire 600 Vac Single Meter Sockets All Eaton sockets are rated 600 Vac maximum and either 100, 200 or 320A continuous. All have a minimum shortcircuit rating of 10,000 rms symmetrical amperes (watthour meter is not included in rating). All single meter sockets are UL labeled and are supplied in surface mounted outdoor enclosures. Confirm local utility acceptance prior to order entry. 5 5 5 5 5 5 5 5 5 5 5 5 5 5 V1-T5-2 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Page V1-T5-3 V1-T5-3 V1-T5-4 V1-T5-8 Metering Products Single Meter Sockets 5.1 Features and Benefits 5 5 Single Meter Sockets 5 Features Benefits Block assembly base exceeds 400 in-lbs of torque Provides durability under the most extreme installation circumstances One-piece, die-run enclosure Eliminates tampering and extends product life High visibility Eaton name embossed on cover Company identity and brand preference Knockouts are installer friendly Labor savings, less time needed for removing knockouts Oversized 7/8-inch diameter, heavy-duty, steel lug screws Stronger connection component facilitates a reliable wire termination Slide-nuts are captive Allow for ease in installation of conductors and eliminates lost components Horn bypass kit is field installable by changing out slide nut Less inventory required and field modifications are simple Integral triplex or quadplex ground extruded in neutral lug One piece for terminating incoming/outgoing neutral conductors, which increases integrity of connections 100% plated bridge with 4-point mounting Zinc chromate plated to provide superior corrosion resistance 5 5 5 5 5 kAIC rating Tested and UL listed up to 200 kAIC rating with specified overcurrent protection devices Provides a complete Eaton residential solution Adding meter sockets to the already existing (loadcenter, surge, breakers, generators and AC disconnect) product lines that we already provide, makes Eaton a one-stop shop for our customers residential and light commercial needs Copper-plated alloy jaws with reinforcing spring Steel reinforcing springs used in all socket jaws to maintain electrical connections 5 5 Catalog Number Selection 5 5 Single Meter Sockets RS Group UT RS 2 0 2 B CH Note: The “U” prefix is always used first followed by other prefixes required in alphabetical order. Standard Prefixes A = Aluminum enclosure B = Barrel lock provision, for an exposed INNER-TITE® or Brooks barrel lock; unit includes an internal lock receiver bracket F = Barrel Lock with guard provision, for a lock guard INNER-TITE or Brooks barrel lock; unit includes an internal lock receiver bracket G = Grounded fifth terminal (9 o’clock position) H = Horn bypass I = Inhibitor installed in wire connectors M = Temporary meter cover (waxed cardboard) N = No sealing ring (applies only to ring style sockets) R = Ring style socket S = Aluminum screw type sealing ring (applies only to ring style sockets) T = Grounding connector (#14–#2 Cu) for triplex ground TT = Two grounding connectors (#14–#2 Cu) for quadplex ground U = UL Underwriters Laboratories label Z = 5/16-inch hex head connector screw in place of slotted (100A only) RS = 2R-6R = 2H-6H = H = 5 Product Group Residential service, single position Residential service, multiple position Commercial or residential service, multiple position Commercial or residential service, single position 5 5 Standard Suffixes A = Solid top B = Small hub opening C = Small hub closing plate mounted L = 1.25-inch (31.8 mm) hub mounted M = 1.50-inch (38.1 mm) hub mounted N = 2.00-inch (50.8 mm) hub mounted P = 2.50-inch (63.5 mm) hub mounted T = Large hub opening hub U = Large hub cover plate hub mounted V = 2.50-inch (63.5 mm) large hub mounted Q = 3.00-inch (76.2 mm) large hub mounted R = 3.50-inch (88.9 mm) large hub mounted S = 4.00-inch (101.6 mm) large hub mounted Z = Large to small hub adapter mounted 5 5 5 5 5 5 Maximum Conductor (Line and Load) 0 = 0.38-inch stud connectors 1 = #2/0 connectors 2 = #250 kcmil connectors 3 = #350 kcmil connectors 5 5 5 Service Design 0 = Overhead 1 = Combination overhead/underground 2 = Underground, side wired 3 = Combination overhead/underground, side wired 5 5 Ampere Rating 1 = 100A 2 = 200A 5 = 150A 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-3 5.1 5 5 Metering Products Single Meter Sockets Product Selection URS212ACH Residential Ringless Type Cover 5 Ampere Rating Jaws Service Bypass Line Load Opening, Hub or Closure Plate Catalog Number 5 200 4 UG — 3/8-inch studs 3/8-inch studs Solid top UTRS240ACH 5 200 4 OH/UG — 3/8-inch studs 3/8-inch studs 3-5/16 hub cover plate UTRS2303CCH 200 4 UG — #8–350 kcmil #8–350 kcmil Solid top UTRS223ACH 200 4 UG — 3/8-inch studs 3/8-inch studs Solid top UTRS220ACH 200 4 OH/UG — #8–350 kcmil #8–350 kcmil 3-5/16 cover plate UTRS213CFLCH 5 200 4 OH/UG — #8–350 kcmil #8–350 kcmil 3-5/16 hub cover plate UTRS213CEPCH 5 200 4 OH/UG — #6–350 kcmil #6–350 kcmil 3-5/16 hub cover plate UGTRS213CE 200 4 OH/UG — #6–350 kcmil #6–350 kcmil 3-5/16 hub cover plate UTRS213CE 5 200 4 OH/UG — #6–350 kcmil #6–350 kcmil 3-5/16 hub opening UATRS213BCH 200 4 OH/UG — #6–350 kcmil #6–350 kcmil 3-5/16 hub opening URS213BCH 5 200 4 OH/UG — #6–350 kcmil #6–350 kcmil 3-5/16 hub opening UTRS213BE 5 200 4 UG — #8–350 kcmil #8–350 kcmil Solid top UTRS213AFLCH 200 4 UG — #8–350 kcmil #8–350 kcmil Solid top UTRS213ACH 5 200 4 OH/UG Horn #8–350 kcmil #8–350 kcmil 3-5/16 hub opening UTRS2138BCH 200 4 OH/UG — #8–250 kcmil #8–250 kcmil Solid top UTRS212ACH 5 200 4 OH/UG — #8–250 kcmil #8–250 kcmil 3-5/16 cover plate UTRS212CCH 5 Connections 200 4 OH/UG — #8–250 kcmil #8–250 kcmil 3-5/16 cover plate UTRS212CFLCH 200 4 OH/UG — #8–250 kcmil #8–250 kcmil 3-5/16 hub opening UTRS212BCH 5 200 4 OH — #8–250 kcmil #8–250 kcmil 2-inch bolt-on hub UTRS202NCH 200 4 OH — #8–250 kcmil #8–250 kcmil Small hub opening UATRS202BFLCH 1 5 200 4 OH/UG — #8–250 kcmil #8–250 kcmil 3-5/16 cover plate UTRS232CCH 200 4 OH — #8–2/0 cu/al #8–2/0 cu/al 3-5/16 hub opening UTRS202BCH 5 200 4 OH/UG — #8–250 kcmil #8–250 kcmil Solid top URS212ACH 5 200 4 OH — #8–250 kcmil #8–250 kcmil 2-inch bolt-on hub URS202NCH 200 5 OH Horn #8–250 kcmil #8–250 kcmil 3-5/16 hub opening URS202BDQCH 200 4 OH/UG Horn #8–350 kcmil #8–350 kcmil 3-5/16 hub cover plate UFHTRS213CCH 2 200 4 OH/UG Horn #8–350 kcmil #8–350 kcmil 3-5/16 hub opening UHTTRS213BCH 5 200 4 OH/UG Horn #8–350 kcmil #8–350 kcmil 3-5/16 hub cover plate UHTTRS213CCH 5 200 4 OH Horn #8–250 kcmil #8–250 kcmil 3-5/16 hub opening UHTTRS202BCH 200 5 OH/UG Horn #8–350 kcmil #8–350 kcmil 3-5/16 hub cover plate UHTRS233CCH 5 200 4 UG Horn #8–350 kcmil #8–350 kcmil Solid top UHTRS223ARHCH 200 4 UG Horn #8–350 kcmil #8–350 kcmil Solid top UFHTRS223ACH 5 200 5 UG Horn #8–350 kcmil #8–350 kcmil Solid top UGHTRS223ACH 5 200 4 UG Horn #8–350 kcmil #8–350 kcmil Solid top UHTTRS223ACH 200 4 UG Horn #8–350 kcmil #8–350 kcmil Solid top UHTRS223ACH 5 200 4 OH/UG Horn #6–350 kcmil #6–350 kcmil 3-5/16 hub opening UHTRS213CE 200 4 OH/UG Horn #6–350 kcmil #6–350 kcmil 3-5/16 hub opening UHTRS213BE 5 200 4 OH/UG Horn #8–350 kcmil #8–350 kcmil Solid top UHTRS213AE 200 4 OH Horn #8–350 kcmil #8–350 kcmil 3-5/16 hub opening UHTRS203BCH 200 4 OH Horn #8–250 kcmil #8–250 kcmil 3-5/16 hub opening UHTRS202BCH 200 4 OH/UG None #8–250 kcmil #8–250 kcmil 2-inch bolt-on hub URS202NPECCH 3 5 5 5 5 Notes 1 Aluminum enclosure. 2 Barrel lock. 3 PEC approved. 5 5 For dimensions, see Pages V1-T5-8 and V1-T5-9. V1-T5-4 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 5.1 Metering Products Single Meter Sockets Residential Ringless Type Cover, continued Connections Ampere Rating Jaws Service Bypass Line 200 4 OH/UG Horn #8–350 kcmil 200 4 OH/UG Horn 200 5 OH/UG 200 5 OH/UG 5 Load Opening, Hub or Closure Plate Catalog Number #8–350 kcmil Solid top UHIRS223ACVCH #8–350 kcmil #8–350 kcmil 3-5/16 hub opening UHIRS213BCVCH — #6–350 kcmil #6–350 kcmil Closure plate UGTRS213CE — #6–350 kcmil #6–350 kcmil Hub opening UGTRS213BE 200 5 OH/UG Horn #6–350 kcmil #6–350 kcmil Closure plate 786685217918 200 5 OH/UG Horn #6–350 kcmil #6–350 kcmil 3-5/16 hub opening UGHTRS213BE 200 5 OH/UG Horn #8–250 kcmil #8–250 kcmil 3-5/16 hub cover plate UGHRS212CKCCH 200 4 OH — #8–250 kcmil #8–250 kcmil 3-5/16 hub opening UFTRS202BCH 5 5 5 5 5 5 200 4 OH Horn #8–250 kcmil #8–250 kcmil 3-5/16 hub opening UFHTRS202BCH 200 4 UG Horn #8–350 kcmil #8–350 kcmil Solid top UBHTRS223ARHCH 200 4 UG Horn #8–350 kcmil #8–350 kcmil Solid top UBHRS223ACH 200 4 OH Horn #8–250 kcmil #8–250 kcmil 3-5/16 hub cover plate UBHRS202BCH 200 4 OH/UG — #8–350 kcmil #8–350 kcmil 3-5/16 hub opening UATRS213CFLCH 5 200 4 OH/UG Horn #8–350 kcmil #8–350 kcmil 3-5/16 hub cover plate UAHTRS233CSHCH 200 4 UG Horn #8–350 kcmil #8–350 kcmil Solid top UAHTRS223AFLCH 200 4 OH Horn #8–250 kcmil #8–250 kcmil 3-5/16 hub opening UAHTRS202BFLCH 200 4 OH/UG — #8–350 kcmil #8–350 kcmil 3-5/16 hub closure plate U92197CCCPLCH 200 4 OH/UG — #8–350 kcmil #8–350 kcmil 3-5/16 hub closure plate 1009928CH 200 4 OH/UG Horn #8–250 kcmil #8–250 kcmil Solid top 1009874ACH 200 4 UG — 3/8-inch studs 3/8-inch studs Solid top 1009046CH 200 4 UG Horn #8–350 kcmil #8–350 kcmil Solid top 1008941CH 200 4 UG Horn #8–350 kcmil #8–350 kcmil Solid top 1008940CH 200 4 UG Horn #8–350 kcmil #8–350 kcmil Solid top 1008827CH 200 4 UG Horn #8–350 kcmil #8–350 kcmil Solid top 1008819CH 200 4 UG Horn #8–350 kcmil #8–350 kcmil Solid top 1008717CH 200 4 UG — #8–350 kcmil #8–350 kcmil Solid top 1008617CH 200 4 OH/UG Horn #8–350 kcmil #8–350 kcmil 3-5/16 hub opening 1007817CH 200 4 OH Horn #8–250 kcmil #8–250 kcmil 3-5/16 hub opening 1007699CH 200 4 OH Horn #8–250 kcmil #8–250 kcmil 3-5/16 hub opening 1007665CH 200 4 UG Horn #8–350 kcmil #8–350 kcmil Solid top 1007588CH 200 4 OH/UG — 3/8-inch studs 3/8-inch studs 3-5/16 hub opening 1007448ACH 200 4 UG Horn #8–350 kcmil #8–350 kcmil Solid top 1004884ARHCH 1 200 4 UG Horn #8–350 kcmil #8–350 kcmil Solid top 1004884ACH 200 4 OH/UG — #8–#250 kcmil #8–#250 kcmil 3-5/16 hub cover plate 1004710ECH 200 4 OH — N/A N/A N/A 1004709DCH 200 4 OH Horn #8–#250 kcmil #8–#250 kcmil 2-inch bolt-on hubs 1004455BCH 200 4 OH Horn #8–250 kcmil #8–250 kcmil 3-5/16 hub opening 1004161ACH 200 4 OH/UG Horn #8–350 kcmil #8–350 kcmil 3-5/16 hub opening 1004159ACH 200 4 OH/UG — #8–350 kcmil #8–350 kcmil Hub closure plate 1008826ACH 2 200 4 OH/UG Lever #6–350 kcmil #6–350 kcmil Hub closure plate 1006352CCH 2 200 5 OH Horn #8–250 kcmil #8–250 kcmil 3-5/16 hub opening 1003879ACH 200 5 OH/UG Horn #8–350 kcmil #8–350 kcmil 3-5/16 hub opening 1003878ACH 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Notes 1 Right hand incoming. 2 Austin Energy approved. 5 For dimensions, see Pages V1-T5-8 and V1-T5-9. 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-5 5.1 5 URS101BCH 5 5 5 5 5 Metering Products Single Meter Sockets Residential Ringless Type Cover, continued Connections Ampere Rating Jaws Service Bypass Line Load Opening, Hub or Closure Plate Catalog Number 150 4 OH/UG — #8–2/0 AWG #8–2/0 AWG Hub closure plate 1004326DCH 1 150 4 OH/UG — #8–250 kcmil #8–250 kcmil Hub opening UTRS502BCH 150 4 OH — #8–250 kcmil #8–250 kcmil 3-5/16 hub opening UTRS502BCH 150 4 OH — #8–250 kcmil #8–250 kcmil 3-5/16 hub cover plate UTRS502CCH 1006385BCH 125 4 UG — N/A N/A N/A 125 4 OH/UG — #8–2/0 cu/al #8–2/0 cu/al 3-5/16 hub opening UTRS111BCH 125 4 OH — #8–2/0 cu/al #8–2/0 cu/al 3-5/16 hub opening UBTRS101BCH 125 4 OH — #8–2/0 cu/al #8–2/0 cu/al 1-1/4-inch bolt-on hub UTRS101LCH 125 4 OH — #8–2/0 cu/al #8–2/0 cu/al 3-5/16 hub cover plate UTRS101CE 125 4 OH — #8–2/0 cu/al #8–2/0 cu/al 3-5/16 hub opening UTRS101BE 125 4 OH — #8–2/0 #8–2/0 3-5/16 hub cover plate URS101CCPLCH 125 4 OH Horn cu/al with 1/2-inch hex head wire clamping screw cu/al with 3-5/16 hub cover plate 1/2-inch hex head wire clamping screw URS101BDQCH 5 125 4 OH — #8–2/0 #8–2/0 3-5/16 hub opening URS101BCPLCH 125 4 OH — #8–2/0 #8–2/0 3-5/16 hub opening URS101BCH 5 125 4 OH Horn #8–2/0 #8–2/0 3-5/16 hub opening UHTTRS101BCH 125 4 OH/UG Horn #8–250 kcmil #8–250 kcmil 3-5/16 hub opening UHTRS111BCH 125 4 OH Horn #8–2/0 #8–2/0 1.25-inch hub mounted UHTRS101LCH 125 4 OH Horn #8–2/0 #8–2/0 Closure plate UHTRS101CE 125 4 OH Horn #8–2/0 #8–2/0 3-5/16 hub opening UHTRS101BE 125 5 OH/UG — #8–2/0 #8–2/0 3-5/16 hub cover plate UGRS10101CKCCH 125 5 OH/UG — #8–2/0 #8–2/0 3-5/16 hub cover plate UGHTRS111CCH 5 125 5 OH — #8–2/0 #8–2/0 3-5/16 hub opening UGHTRS101BCH 5 125 4 OH — #8–2/0 #8–2/0 3-5/16 hub cover plate UBHRS101BCH 125 4 OH/UG — #8–2/0 #8–2/0 3-5/16 hub cover plate UATZRS101CFLCH 5 5 5 5 5 5 5 125 4 OH — #8–2/0 #8–2/0 3-5/16 hub cover plate UATRS101CCH 125 4 OH — #8–2/0 #8–2/0 3-5/16 hub opening 1008947CH 5 125 4 UG N/A N/A N/A N/A 1005826ACH 5 125 4 OH — #8–2/0 #8–2/0 1-1/4-inch bolt-on hub 1004931BCH 125 4 OH — #8–2/0 #8–2/0 3-5/16 hub opening 1004162ACH 5 125 5 OH — #8–2/0 #8–2/0 3-5/16 hub opening 1003880ACH 125 4 OH — #8–2/0 #8–2/0 3-5/16 hub opening UTZRS101BFLCH 5 125 4 OH — #8–2/0 #8–2/0 3-5/16 hub closure plate UTZRS101CFLCH 125 5 OH Horn #8–2/0 #8–2/0 Hub opening UTRS101CEPSEG 2 100 4 OH — #8–2/0 #8–2/0 3-5/16 hub opening 1009079CH 200 5 OH/UG Horn #8–350 kcmil #8–350 kcmil Hub closure plate UTRS213CEPSEG 2 5 5 5 Notes 1 Austin Energy approved. 2 PSE&G approved. 5 For dimensions, see Pages V1-T5-8 and V1-T5-9. 5 5 5 5 5 V1-T5-6 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Single Meter Sockets 5.1 Residential Ring Type Cover Connections Ampere Rating Jaws Service Line 200 4 UG #8–350 kcmil 200 4 OH/UG 200 4 200 5 Load Opening, Hub or Closure Plate Catalog Number #8–350 kcmil Solid top URTRS223ACH #8–350 kcmil #8–350 kcmil 3-5/16 hub cover plate URRS213CCH OH/UG #8–350 kcmil #8–350 kcmil 2 inch hub mounted URTRS213NEUSCH 4 OH/UG #8–350 kcmil #8–350 kcmil 3-5/16 hub cover plate URTRS213CEUSCH 200 4 OH/UG #8–350 kcmil #8–350 kcmil 3-5/16 hub cover plate 1009424CH 200 4 OH/UG #8–350 kcmil #8–350 kcmil Knockouts 1009449CH 200 4 OH #8–350 kcmil #8–350 kcmil 3-5/16 hub opening URSTRS203BCH 200 4 OH #8–250 kcmil #8–250 kcmil 3-5/16 hub cover plate URS212BCRCH 200 4 OH/UG #8–250 kcmil #8–250 kcmil 3-5/16 hub cover plate URTRS202BCH 200 4 OH #8–250 kcmil #8–250 kcmil 3-5/16 hub opening URTRS213BE 200 4 OH/UG #6–350 kcmil #6–350 kcmil Hub opening URTRS202BCH 200 4 OH/UG #6–350 kcmil #6–350 kcmil Closure plate URTRS213CE 200 4 UG #6–350 kcmil #6–350 kcmil 3-5/16 hub opening URTRS213BEUSCH 200 4 OH #8–250 kcmil #8–250 kcmil 2-inch hub mounted URTRS202NEUSCH 200 4 OH #8–250 kcmil #8–250 kcmil 3-5/16 hub opening UNRRS202BEUSCH 200 4 OH/UG #6–350 kcmil #6–350 kcmil Closure plate UNRRS213CEUSE 200 4 OH #8–250 kcmil #8–250 kcmil Hub opening UNRRS213BEUSE 200 4 UG #6–350 kcmil #6–350 kcmil Solid top UNRRS213AEUSE 200 4 OH/UG #6–250 kcmil #6–250 kcmil 5x5 hub opening 3-5/16 adapter plate 1009097CH 125 4 OH #8–2/0 cu/al #8–2/0 cu/al 3-5/16 hub opening URS101BCRCH 125 4 OH #8–2/0 cu/al #8–2/0 cu/al 1-1/4-inch bolt-on hub URRS101LCH 125 4 OH #8–2/0 cu/al #8–2/0 cu/al Hub cover plate URTRS101BE 125 4 OH #8–2/0 cu/al #8–2/0 cu/al Hub cover plate URTRS101CE 125 4 OH #8–2/0 cu/al #8–2/0 cu/al 3-5/16 hub cover plate UNRRS101BEUSE 125 4 OH #8–2/0 cu/al #8–2/0 cu/al Closure plate UNRRS101CEUSE 125 4 OH/UG #8–2/0 cu/al #8–2/0 cu/al 3-5/16 hub cover plate UNRRS111BEUSE 125 4 UG #8–2/0 cu/al #8–2/0 cu/al Solid top UNRRS111AEUSE 125 4 OH #8–2/0 cu/al #8–2/0 cu/al 3-5/16 hub opening URSTRS101BCH 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Note For dimensions, see Pages V1-T5-8 and V1-T5-9. 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-7 5.1 5 Metering Products Single Meter Sockets Dimensions Approximate Dimensions in Inches (mm) 5 5 Residential Ringless Type Cover Residential Ringless Type Cover, continued Catalog Number Height Width Depth Catalog Number Height Width UTRS240ACH 18.63 (473.2) 13.00 (330.2) 4.94 (125.5) UHIRS213BCVCH 15.00 (381.0) 11.00 (279.4) 4.38 (111.3) 5 UTRS2303CCH 20.00 (508.0) 13.00 (330.2) 4.94 (125.5) UGTRS213CE 15.13 (384.3) 11.25 (285.8) 4.50 (114.3) UTRS223ACH 13.00 (330.2) 13.00 (330.2) 4.94 (125.5) UGTRS213BE 15.13 (384.3) 11.25 (285.8) 4.50 (114.3) 5 UTRS220ACH 15.13 (384.3) 13.00 (330.2) 4.94 (125.5) 786685217918 15.13 (384.3) 11.25 (285.8) 4.50 (114.3) UTRS213CFLCH 15.00 (381.0) 11.00 (279.4) 4.37 (111.0) UGHTRS213BE 15.13 (384.3) 11.25 (285.8) 4.50 (114.3) UTRS213CEPCH 15.00 (381.0) 11.00 (279.4) 4.37 (111.0) UGHRS212CKCCH 14.00 (355.6) 11.00 (279.4) 4.38 (111.3) 5 UGTRS213CE 15.13 (384.3) 11.25 (285.8) 4.50 (114.3) UFTRS202BCH 14.00 (355.6) 8.00 (203.2) 4.38 (111.3) UTRS213CE 15.13 (384.3) 11.25 (285.8) 4.50 (114.3) UFHTRS202BCH 14.00 (355.6) 8.00 (203.2) 4.38 (111.3) 5 UATRS213BCH 15.13 (384.3) 11.25 (285.8) 4.50 (114.3) UBHTRS223ARHCH 13.00 (330.2) 13.00 (330.2) 4.94 (125.5) URS213BCH 15.00 (381.0) 11.00 (279.4) 4.36 (110.7) UBHRS223ACH 13.00 (330.2) 13.00 (330.2) 4.94 (125.5) 5 UTRS213BE 15.13 (384.3) 11.25 (285.8) 4.50 (114.3) UBHRS202BCH 14.00 (355.6) 8.00 (203.2) 4.38 (111.3) 5 UTRS213AFLCH 15.00 (381.0) 11.00 (279.4) 4.37 (111.0) UATRS213CFLCH 15.00 (381.0) 11.00 (279.4) 4.38 (111.3) UTRS213ACH 15.00 (381.0) 11.00 (279.4) 4.36 (110.7) UAHTRS233CSHCH 17.13 (435.1) 13.00 (330.2) 4.94 (125.5) UTRS2138BCH 20.00 (508.0) 13.00 (330.2) 4.94 (125.5) UAHTRS223AFLCH 13.00 (330.2) 13.00 (330.2) 4.94 (125.5) UTRS212ACH 14.00 (355.6) 11.00 (279.4) 4.37 (111.0) UAHTRS202BFLCH 14.00 (355.6) 8.00 (203.2) 4.38 (111.3) 5 UTRS212CCH 14.00 (355.6) 11.00 (279.4) 4.36 (110.7) U92197CCCPLCH 14.13 (358.9) 13.00 (330.2) 4.94 (125.5) 5 UTRS212CFLCH 14.00 (355.6) 11.00 (279.4) 4.36 (110.7) 1009928CH 15.00 (381.0) 11.00 (279.4) 4.38 (111.3) UTRS212BCH 14.00 (355.6) 11.00 (279.4) 4.36 (110.7) 1009874ACH 15.00 (381.0) 13.00 (330.2) 4.94 (125.5) 5 UTRS202NCH 14.00 (355.6) 8.00 (203.2) 4.36 (110.7) 1009046CH 20.75 (527.1) 9.00 (228.6) 4.94 (125.5) 14.00 (355.6) 8.00 (203.2) 4.36 (110.7) 1008941CH 17.13 (435.1) 13.00 (330.2) 4.94 (125.5) 5 UTRS232CCH 17.12 (434.8) 13.00 (330.2) 4.93 (125.2) 1008940CH 17.13 (435.1) 13.00 (330.2) 4.94 (125.5) 5 UTRS202BCH 14.00 (355.6) 8.00 (203.2) 4.36 (110.7) 1008827CH 13.00 (330.2) 13.00 (330.2) 4.94 (125.5) URS212ACH 14.00 (355.6) 11.00 (279.4) 4.38 (111.3) 1008819CH 13.00 (330.2) 13.00 (330.2) 4.94 (125.5) 5 URS202NCH 14.00 (355.6) 8.00 (203.2) 4.38 (111.3) 1008717CH 15.00 (381.0) 13.00 (330.2) 4.94 (125.5) URS202BDQCH 14.00 (355.6) 8.00 (203.2) 4.38 (111.3) 1008617CH 15.00 (381.0) 13.00 (330.2) 4.94 (125.5) 5 UFHTRS213CCH 2 15.00 (381.0) 11.00 (279.4) 4.38 (111.3) 1007817CH 15.00 (381.0) 11.00 (279.4) 4.38 (111.3) UHTTRS213BCH 15.00 (381.0) 11.00 (279.4) 4.38 (111.3) 1007699CH 14.00 (355.6) 8.00 (203.2) 4.38 (111.3) UHTTRS213CCH 15.00 (381.0) 11.00 (279.4) 4.38 (111.3) 1007665CH 14.00 (355.6) 8.00 (203.2) 4.38 (111.3) UHTTRS202BCH 14.00 (355.6) 8.00 (203.2) 4.38 (111.3) 1007588CH 13.00 (330.2) 13.00 (330.2) 4.94 (125.5) UHTRS233CCH 17.13 (435.1) 13.00 (330.2) 4.94 (125.5) 1007448ACH 19.00 (482.6) 11.00 (279.4) 4.38 (111.3) 5 5 5 5 5 5 UATRS202BFLCH 1 3 Depth UHTRS223ARHCH 13.00 (330.2) 13.00 (330.2) 4.94 (125.5) 1004884ARHCH 13.00 (330.2) 13.00 (330.2) 4.93 (125.2) UFHTRS223ACH 13.00 (330.2) 13.00 (330.2) 4.94 (125.5) 1004884ACH 13.00 (330.2) 13.00 (330.2) 4.93 (125.2) 5 UGHTRS223ACH 13.00 (330.2) 13.00 (330.2) 4.94 (125.5) 1004710ECH 14.00 (355.6) 11.00 (279.4) 4.38 (111.3) 5 UHTTRS223ACH 13.00 (330.2) 13.00 (330.2) 4.94 (125.5) 1004709DCH N/A N/A N/A UHTRS223ACH 13.00 (330.2) 13.00 (330.2) 4.94 (125.5) 1004455BCH 15.00 (381.0) 8.00 (203.2) 4.38 (111.3) UHTRS213CE 15.00 (381.0) 11.00 (279.4) 4.38 (111.3) 1004161ACH 14.00 (355.6) 8.00 (203.2) 4.38 (111.3) UHTRS213BE 15.00 (381.0) 11.00 (279.4) 4.38 (111.3) 1004159ACH 15.00 (381.0) 11.00 (279.4) 4.38 (111.3) 5 UHTRS213AE 15.00 (381.0) 11.00 (279.4) 4.38 (111.3) 1003879ACH 15.00 (381.0) 8.00 (203.2) 4.38 (111.3) 5 UHTRS203BCH 15.00 (381.0) 8.00 (203.2) 4.38 (111.3) 1003878ACH 15.00 (381.0) 11.00 (279.4) 4.38 (111.3) UHTRS202BCH 14.00 (355.6) 8.00 (203.2) 4.38 (111.3) UTRS502BCH 14.00 (355.6) 8.00 (203.2) 4.38 (111.3) UHIRS223ACVCH 13.00 (330.2) 13.00 (330.2) 4.94 (125.5) Notes 1 Aluminum enclosure. 2 Barrel lock. 3 Right hand incoming. 5 5 5 5 V1-T5-8 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 5.1 Metering Products Single Meter Sockets Approximate Dimensions in Inches (mm) 5 Residential Ringless Type Cover, continued 5 Residential Ring Type Cover Catalog Number Height Width Depth Catalog Number Height Width Depth UTRS502BCH 14.00 (355.6) 8.00 (203.2) 4.36 (110.7) URTRS223ACH 13.00 (330.2) 13.00 (330.2) 4.93 (125.2) UTRS502CCH 14.00 (355.6) 8.00 (203.2) 4.36 (110.7) URRS213CCH 15.00 (381.0) 11.00 (279.4) 4.38 (111.3) 1006385BCH N/A N/A N/A URTRS213NEUSCH 15.00 (381.0) 11.00 (279.4) 4.38 (111.3) UTRS111BCH 14.00 (355.6) 11.00 (279.4) 4.36 (110.7) URTRS213CEUSCH 15.00 (381.0) 11.00 (279.4) 4.38 (111.3) UBTRS101BCH 10.88 (276.4) 8.00 (203.2) 3.50 (88.9) 1009424CH 15.00 (381.0) 11.00 (279.4) 4.38 (111.3) UTRS101LCH 10.88 (276.4) 8.00 (203.2) 3.50 (88.9) 1009449CH 18.31 (465.1) 14.19 (360.4) 5.13 (130.3) UTRS101CE 11.05 (280.7) 8.22 (208.8) 3.61 (91.7) URSTRS203BCH N/A N/A N/A UTRS101BE 11.05 (280.7) 8.22 (208.8) 3.61 (91.7) URS212BCRCH 14.00 (355.6) 8.00 (203.2) 4.38 (111.3) URS101CCPLCH 10.88 (276.4) 8.00 (203.2) 3.50 (88.9) URTRS202BCH 14.00 (355.6) 11.00 (279.4) 4.38 (111.3) URS101BDQCH 10.88 (276.4) 8.00 (203.2) 3.50 (88.9) URTRS213BE 14.00 (355.6) 8.00 (203.2) 4.50 (114.3) URS101BCPLCH 10.88 (276.4) 8.00 (203.2) 3.50 (88.9) URTRS202BCH 15.13 (384.3) 11.25 (285.8) 4.50 (114.3) URS101BCH 10.88 (276.4) 8.00 (203.2) 3.50 (88.9) URTRS213CE 15.13 (384.3) 11.25 (285.8) 4.50 (114.3) UHTTRS101BCH 10.88 (276.4) 8.00 (203.2) 3.50 (88.9) URTRS213BEUSCH 15.13 (384.3) 11.25 (285.8) 4.50 (114.3) UHTRS111BCH 14.00 (355.6) 11.00 (279.4) 4.38 (111.3) URTRS202NEUSCH 14.00 (355.6) 8.00 (203.2) 4.38 (111.3) UHTRS101LCH 10.88 (276.4) 8.00 (203.2) 3.50 (88.9) UNRRS202BEUSCH 14.00 (355.6) 8.00 (203.2) 4.38 (111.3) UHTRS101CE 11.05 (280.7) 8.22 (208.8) 3.61 (91.7) UNRRS213CEUSE 15.13 (384.3) 11.25 (285.8) 4.50 (114.3) UHTRS101BE 11.05 (280.7) 8.22 (208.8) 3.61 (91.7) UNRRS213BEUSE 15.13 (384.3) 11.25 (285.8) 4.50 (114.3) UGRS10101CKCCH 12.00 (304.8) 8.00 (203.2) 3.50 (88.9) UNRRS213AEUSE 15.13 (384.3) 11.25 (285.8) 4.50 (114.3) UGHTRS111CCH 14.00 (355.6) 11.00 (279.4) 4.36 (110.7) 1009097CH 19.00 (482.6) 13.00 (330.2) 5.25 (133.4) UGHTRS101BCH 10.88 (276.4) 8.00 (203.2) 3.50 (88.9) URS101BCRCH 10.88 (276.4) 8.00 (203.2) 3.50 (88.9) UBHRS101BCH 10.88 (276.4) 8.00 (203.2) 3.50 (88.9) URRS101LCH 10.88 (276.4) 8.00 (203.2) 3.50 (88.9) UATZRS101CFLCH 10.88 (276.4) 8.00 (203.2) 3.50 (88.9) URTRS101BE 11.00 (279.4) 8.25 (209.6) 3.63 (92.2) UATRS101CCH 10.87 (276.1) 8.00 (203.2) 3.50 (88.9) URTRS101CE 11.00 (279.4) 8.25 (209.6) 3.63 (92.2) 1008947CH 10.89 (276.6) 8.00 (203.2) 3.50 (88.9) UNRRS101BEUSE 10.88 (276.4) 8.00 (203.2) 3.50 (88.9) 1005826ACH N/A N/A N/A UNRRS101CEUSE 10.88 (276.4) 8.00 (203.2) 3.50 (88.9) 1004931BCH 10.88 (276.4) 8.00 (203.2) 3.50 (88.9) UNRRS111BEUSE 14.00 (355.6) 11.00 (279.4) 4.38 (111.3) 1004162ACH 10.89 (276.6) 8.00 (203.2) 3.50 (88.9) URSTRS101BCH 10.88 (276.4) 8.00 (203.2) 3.50 (88.9) 1003880ACH 10.89 (276.6) 8.00 (203.2) 3.50 (88.9) UTZRS101BFLCH N/A N/A N/A UTZRS101CFLCH N/A N/A N/A 1009079CH 23.75 (603.3) 8.00 (203.2) 3.48 (88.4) 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-9 5.2 5 Metering Products Commercial Lever Bypass Sockets Contents Commercial Lever Bypass Sockets Description 5 Catalog Number Selection . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 5 5 5 5 5 5 5 5 5 Product Description ● 5 ● 5 ● 5 5 5 ● ● ● Heavy-duty, lever bypass, jaw clamping ringless meter socket design 200A and 320A styles available Single-phase or three-phase 4, 5 or 7 terminal available 600 Vac maximum rating Multiple service design offerings Standards and Certifications ● UL 414 listed and recognized 5 5 5 5 5 5 5 5 5 5 5 5 5 V1-T5-10 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Page V1-T5-11 V1-T5-12 V1-T5-16 Metering Products Commercial Lever Bypass Sockets 5.2 Catalog Number Selection 5 5 Single Meter Sockets H Group 5 UT H 4 2 0 3 B CH Note: The “U” prefix is always used first followed by other prefixes required in alphabetical order. Standard Prefixes A = Aluminum enclosure B = Barrel lock provision, for an exposed INNER-TITE or Brooks barrel lock; unit includes an internal lock receiver bracket F = Barrel Lock with guard provision, for a lock guard INNER-TITE or Brooks barrel lock; unit includes an internal lock receiver bracket G = Grounded fifth terminal (9 o’clock position) H = Horn bypass I = Inhibitor installed in wire connectors M = Temporary meter cover (waxed cardboard) N = No sealing ring (applies only to ring style sockets) R = Ring style socket S = Aluminum screw type sealing ring (applies only to ring style sockets) T = Grounding connector (#14–#2 Cu) for triplex ground TT = Two grounding connectors (#14–#2 Cu) for quadplex ground U = UL label Z = 5/16-inch hex head connector screw in place of slotted (100A only) RS 2R-6R 2H-6H H = = = = 5 Standard Suffixes Product Group Residential service, single position Residential service, multiple position Commercial or residential service, multiple position Commercial or residential service, single position Jaw Quantity 4 = 4 terminals 5 = 5 terminals 7 = 7 terminals 5 A = Solid top B = Small hub opening C = Small hub closing plate mounted L = 1.25-inch (31.8 mm) hub mounted M = 1.50-inch (38.1 mm) hub mounted N = 2.00-inch (50.8 mm) hub mounted P = 2.50-inch (63.5 mm) hub mounted T = Large hub opening hub U = Large hub cover plate hub mounted V = 2.50-inch (63.5 mm) large hub mounted Q = 3.00-inch (76.2 mm) large hub mounted R = 3.50-inch (88.9 mm) large hub mounted S = 4.00-inch (101.6 mm) large hub mounted Z = Large to small hub adapter mounted 5 5 5 5 5 Maximum Conductor (Line & Load) 0 = 0.38-inch stud connectors 3 = #350 kcmil connectors 5 = #500 kcmil connectors 6 = #600 kcmil connectors 7 = #750 kcmil connectors 8 = Dual #250 kcmil connectors 9 = Dual #350 kcmil connectors 5 5 5 5 Service Design 0 = Overhead 1 = Combination overhead/underground 2 = Underground, side wired 3 = Combination overhead/underground, side wired 5 5 Ampere Rating 2 = 200A 3 = 320A 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-11 5.2 Metering Products Commercial Lever Bypass Sockets 5 Product Selection 5 Commercial Lever Bypass 5 Ampere Rating Jaws Service Bypass Line 5 320 7 OH/UG Lever 320 7 OH Lever 5 320 7 OH/UG 320 7 OH/UG 5 Connections Load Opening, Hub or Closure Plate Catalog Number #4-600 kcmil #4–600 kcmil 5x5 hub opening UTTH7336TCH #600 kcmil Dual #6–350 5x5 hub opening UTH73069THLCH Lever #14–1/0 cu/al #6–350 kcmil 5x5 hub cover plate UTH73369UHLCH Lever #14–1/0 cu/al #6–350 kcmil 5x5 hub opening UTH73369THLCH 320 7 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub cover plate UFTH7330UCH 5 320 7 OH/UG Lever #600 kcmil #600 kcmil 5x5 hub opening UTH7336TCH 320 7 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub cover plate UTH7330UCH 5 320 7 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub cover plate UTH7330UFLCH 320 7 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub cover plate UATH7330UFLCH 1 320 7 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening UH7330TCPLCH 5 5 320 7 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening UTH7330TCH 320 7 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub-inch opening UTTH7330TCH 5 320 7 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub cover plate UH7300UCPLCH 320 7 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub cover plate UTH7300UCH 320 7 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening UTH7300TCH 320 7 OH/UG Lever #6–350 kcmil #6–350 kcmil Hub closure plate 1006353CCH 2 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 320 5 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub cover plate UTH5330UFLCH 320 5 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub cover plate UTH5330UCH 320 5 OH Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening UTH5300TCH 320 5 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub cover plate UATH5330UFLCH 320 4 OH/UG lever #4–600 kcmil #4–600 kcmil Hub closure plate 1010468CH 2 320 4 UG Lever 3/8-inch studs 3/8-inch studs Solid top UTH4320ACH 320 4 UG Lever 3/8-inch studs Dual #6–350 Solid top UTH43209ACH 320 4 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub cover plate UTH4339UCH 320 4 OH/UG Lever #6–250 kcmil #6–250 kcmil 5x5 hub cover plate UTH4338UCH 320 4 OH/UG Lever #4–600 kcmil #4–600 kcmil 5x5 hub cover plate UTH4336UCH 320 4 OH/UG Lever #4–600 kcmil #4–600 kcmil 5x5 hub opening UTH4336TCH 320 4 OH/UG Lever #4–600 kcmil #6–350 kcmil 5x5 hub cover plate UTH43369UCH UTH43369TCH 320 4 OH/UG Lever #4–600 kcmil #6–350 kcmil 5x5 hub opening 320 4 OH/UG Lever 3/8-inch studs 3/8-inch studs 3-5/16 hub cover plate UTTH4330UCH 320 4 OH/UG Lever 3/8-inch studs 3/8-inch studs 3-5/16 hub cover plate UTH4330UCH 320 4 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening UBTH4330TCH 320 4 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening UTH4330TCH 320 4 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 cover plate UTH4300UCH 320 4 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening UTH4300TCH 320 5 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub cover plate UH5300UKCCH 320 4 OH/UG Lever #6–250 kcmil #4–600 kcmil 5x5 hub cover plate UH43168UCPLCH 320 4 OH/UG Lever #4–600 kcmil #6–250 kcmil 5x5 hub cover plate UH43068TCPLCH 320 5 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub cover plate UGTH4330UCH 320 5 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening UGTH4330TCH 320 7 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening UFTH7330TCH 320 4 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening UFTH4330TCH 5 Notes 1 Aluminum enclosure. 2 Austin Energy approved. 5 For dimensions, see Pages V1-T5-16 and V1-T5-17. V1-T5-12 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Commercial Lever Bypass Sockets 5.2 Commercial Lever Bypass, continued Connections Ampere Rating Jaws Service Bypass Line 320 7 OH/UG Lever #4–600 kcmil 320 5 OH/UG Lever 320 4 OH/UG Lever 320 4 OH/UG 320 4 320 4 320 4 OH/UG Lever Dual #6–350 320 4 OH/UG Lever Dual #6–350 320 4 OH/UG Lever 3/8-inch studs 320 4 OH/UG Lever 320 7 OH/UG Lever 320 4 UG 320 4 320 4 320 5 Load Opening, Hub or Closure Plate Catalog Number #4–600 kcmil 5x5 hub opening UATH7336TCH 3/8-inch studs 3/8-inch studs 5x5 hub cover plate UATH5330UFLCH #4–600 kcmil #4–600 kcmil 5x5 hub opening UATH4336TCH Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening UATH4330TCH OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub cover plate 1009788CH OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub cover plate 1009788ACH 1 Dual #6–350 (2) 5x5 hub cover plates 1009760ACH Dual #6–350 5x5 hub cover plate 1009722CH 3/8-inch studs 5x5 hub cover plate 782116975945 3/8-inch studs 3/8-inch studs 5x5 hub cover plate 1009260CH #4–600 kcmil/Dual 1/0–250 kcmil cu/al #4–600 kcmil/Dual 1/0–250 kcmil cu/al 5x5 hub opening 1009181CH Lever #6–350 kcmil #6–350 kcmil Solid top 1009018CH OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening 1008950CH OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening 1008948CH 4 UG Lever 3/8-inch studs 3/8-inch studs Solid top 1008848CH 320 4 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening 1008837CH 320 4 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening 1008836CH 320 7 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening 1008798CH 320 4 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening 1008793CH 320 5 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening 1008792CH 320 7 OH/UG Lever #4–600 kcmil/Dual 1/0–250 kcmil cu/al #4–600 kcmil/Dual 1/0–250 kcmil cu/al 5x5 hub opening 1008543CH 5 320 4 OH/UG Lever #4–600 kcmil cu/al #4–600 kcmil cu/al 5x5 hub opening 1008541CH 320 4 UG Lever N/A N/A Solid top 1008540CH 5 320 4 OH/UG Lever #4–600 kcmil cu/al #4–600 kcmil cu/al Solid top 1008435CH 320 4 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening 1008191CH 320 4 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub opening 1008068CH 320 4 OH/UG Lever N/A N/A N/A 1007818CH 320 4 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening 1007801CH 320 4 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub opening 1007672CH 320 4 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub opening 1006344ACH 320 4 OH/UG Lever TBD TBD 5x5 hub opening 1004984ACH 320 4 OH/UG N/A #4–600 kcmil #4–600 kcmil 3-inch bolt-on hub 1004771BCH 200 7 OH/UG Lever 3/8-inch studs 3/8-inch studs N/A UBTH7230ACH 200 7 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub cover plate UTH7233UCH 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Notes 1 Bolted in shield. 5 5 5 For dimensions, see Pages V1-T5-16 and V1-T5-17. 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-13 5.2 Metering Products Commercial Lever Bypass Sockets 5 Commercial Lever Bypass, continued 5 Ampere Rating Jaws Service Bypass Line Load Opening, Hub or Closure Plate Catalog Number 200 7 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub cover plate UTE7213UFLCH 200 7 OH/UG Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub cover plate UETH72137UCH 200 7 OH/UG Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub cover plate UTE7213UCH 200 7 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub opening UTE7213THLCH 5 200 7 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub opening UBHRS212BCH 5 200 7 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub opening UBEH7213TCH 200 7 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub opening UFTE7213TCH 1 5 200 7 OH/UG Lever #6–350 kcmil #6–350 kcmil Large to small hub adapter UTE7213ZCH 200 7 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub opening UTE7213TCH 5 200 7 OH/UG Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub cover plate UTE7213CFLCH 5 200 7 OH/UG Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub cover plate UTE7213CCH 200 7 OH/UG Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub opening UBTE7213BCH 200 7 OH/UG Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub opening UTE7213BCH 200 7 OH/UG Lever 3/8-inch studs 3/8-inch studs 5x5 hub cover plate UTE7210UCH UTE7203TCH 5 5 5 5 Connections 200 7 OH Lever #6–350 kcmil #6–350 kcmil 5x5 hub opening 200 7 OH Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub opening UTE7203BCH 200 5 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub cover plate UETH5213UCH 5 200 5 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub opening UTE5213TCH 200 5 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub opening UTTE5213TCH 5 200 5 OH/UG Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub cover plate UTE5213CCH 200 5 OH/UG Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub opening UTE5213BNDCH 5 200 5 OH/UG Lever #6–350 kcmil #6–350 kcmil Large to small hub adapter UTE5213ZCH 5 200 5 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub cover plate UTE5213UFLCH 200 5 OH/UG Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub cover plate UTE5213CFLCH 200 5 OH/UG Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub opening UTE5213BCH 200 5 OH/UG Lever 3/8-inch studs 3/8-inch studs 3-5/16 hub cover plate UTE5210CCH 5 200 5 OH Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub opening UTE5203BCH 5 200 4 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub opening with adapter plate UTE4213ZCH 200 5 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub cover plate UGTE4213CCH 200 4 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub opening UTE4213TCH 200 4 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub cover plate UTTE4213UCH 2 5 5 5 5 5 5 5 5 5 5 200 4 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub cover plate UTE4213CCH 200 4 OH/UG Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub opening UTE4213BCH 200 4 OH Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub opening UTE4203BCH 200 7 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub cover plate UIH7213UCVCH 200 7 OH/UG Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub cover plate UE7213CCCCH 200 7 OH/UG Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub cover plate UE7213CCPLCH 200 7 OH/UG Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub opening UE7213BCPLCH Notes 1 Barrel lock. 2 TT = quadplex ground. For dimensions, see Pages V1-T5-16 and V1-T5-17. 5 5 5 V1-T5-14 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Commercial Lever Bypass Sockets 5.2 Commercial Lever Bypass, continued Connections Ampere Rating Jaws Service Bypass Line 200 5 OH/UG Lever #6–350 kcmil 200 4 OH/UG Lever 200 7 OH/UG Lever 200 7 OH/UG 5 Load Opening, Hub or Closure Plate Catalog Number #6–350 kcmil 3-5/16 hub opening UGTE4213BCH #6–350 kcmil #6–350 kcmil 3-5/16 hub cover plate UGE4213CCCCH #6–350 kcmil #6–350 kcmil 3-5/16 hub opening UFTE7213BCH Lever #6–350 kcmil #6–350 kcmil 5x5 hub opening UATE7213TCH 200 5 OH/UG Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub cover plate UATE5213CCH 200 4 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub cover plate UATE4213UFLCH 200 5 OH Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub opening UBGTE4203BCH 200 7 UG Lever 4/0 compression line #6–350 kcmil cu/al load Solid top 1009845ECH 200 5 OH/UG Lever #6–350 kcmil #6–350 kcmil 3-5/16 hub cover plate 1008801ECH 200 5 OH/UG Lever 3/8-inch studs 3/8-inch studs 3-5/16 hub cover plate 1008832ECH 200 4 UG Lever #6–350 kcmil #6–350 kcmil Solid top 1007944ECH 200 7 OH/UG Lever #6–350 kcmil cu/al #6–350 kcmil cu/al 5x5 hub opening 1007670ECH 200 7 OH/UG Lever #6–350 kcmil #6–350 kcmil 5x5 hub opening UTTE7213TCH 5 5 5 5 5 5 5 5 Note For dimensions, see Pages V1-T5-16 and V1-T5-17. 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-15 5.2 5 Metering Products Commercial Lever Bypass Sockets Dimensions Approximate Dimensions in Inches (mm) 5 5 Commercial Lever Bypass Commercial Lever Bypass, continued Catalog Number Height Width Depth Catalog Number Height Width Depth UTTH7336TCH 39.89 (1013.2) 20.00 (508.0) 6.50 (165.1) UATH7336TCH 39.88 (1013.0) 20.00 (508.0) 6.50 (165.1) 5 UTH73069THLCH N/A N/A N/A UATH5330UFLCH 39.88 (1013.0) 20.00 (508.0) 6.50 (165.1) UTH73369UHLCH 39.89 (1013.2) 20.00 (508.0) 6.50 (165.1) UATH4336TCH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) 5 UTH73369THLCH 39.89 (1013.2) 20.00 (508.0) 6.50 (165.1) UATH4330TCH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) UFTH7330UCH 39.89 (1013.2) 20.00 (508.0) 6.50 (165.1) 1009788CH 34.50 (876.3) 13.00 (330.2) 4.94 (125.5) UTH7336TCH 39.89 (1013.2) 20.00 (508.0) 6.50 (165.1) 1009788ACH 2 34.50 (876.3) 13.00 (330.2) 4.94 (125.5) UTH7330UCH 39.89 (1013.2) 20.00 (508.0) 6.50 (165.1) 1009760ACH 36.63 (930.4) 15.00 (381.0) 5.68 (144.3) UTH7330UFLCH 39.89 (1013.2) 20.00 (508.0) 6.50 (165.1) 1009722CH 36.63 (930.4) 15.00 (381.0) 5.68 (144.3) 5 5 5 5 1 39.89 (1013.2) 20.00 (508.0) 6.50 (165.1) 782116975945 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) UH7330TCPLCH 39.89 (1013.2) 20.00 (508.0) 6.50 (165.1) 1009260CH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) 5 UTH7330TCH 39.89 (1013.2) 20.00 (508.0) 6.50 (165.1) 1009181CH 34.50 (876.3) 15.00 (381.0) 5.69 (144.5) 5 UTTH7330TCH 39.89 (1013.2) 20.00 (508.0) 6.50 (165.1) 1009018CH 63.00 (1600.2) 12.97 (329.4) 4.94 (125.5) UH7300UCPLCH 39.89 (1013.2) 20.00 (508.0) 6.50 (165.1) 1008950CH 39.88 (1013.0) 20.00 (508.0) 6.50 (165.1) UTH7300UCH 39.89 (1013.2) 20.00 (508.0) 6.50 (165.1) 1008948CH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) UTH7300TCH 34.50 (876.3) 15.00 (381.0) 5.63 (143.0) 1008848CH 58.00 (1473.2) 12.97 (329.4) 4.94 (125.5) 5 UTH5330UFLCH 39.88 (1013.0) 20.00 (508.0) 6.50 (165.1) 1008837CH 36.63 (930.4) 15.00 (381.0) 6.50 (165.1) 5 UTH5330UCH 39.88 (1013.0) 20.00 (508.0) 6.50 (165.1) 1008836CH 36.63 (930.4) 15.00 (381.0) 6.50 (165.1) UTH5300TCH 39.88 (1013.0) 20.00 (508.0) 6.50 (165.1) 1008798CH 34.50 (876.3) 15.00 (381.0) 5.69 (144.5) 5 UATH5330UFLCH 39.88 (1013.0) 20.00 (508.0) 6.50 (165.1) 1008793CH 34.50 (876.3) 13.00 (330.2) 4.94 (125.5) UTH4320ACH 26.00 (660.4) 15.00 (381.0) 5.68 (144.3) 1008792CH 34.50 (876.3) 13.00 (330.2) 4.94 (125.5) 5 UTH43209ACH N/A N/A N/A 1008543CH 39.89 (1013.2) 20.00 (508.0) 6.60 (167.6) 5 UTH4339UCH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) 1008541CH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) UTH4338UCH 29.00 (736.6) 15.00 (381.0) 5.69 (144.5) 1008540CH N/A N/A N/A 5 UTH4336UCH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) 1008435CH 26.00 (660.4) 15.00 (381.0) 5.69 (144.5) UTH4336TCH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) 1008191CH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) 5 UTH43369UCH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) 1008068CH 34.50 (876.3) 16.44 (417.6) 6.50 (165.1) UTH43369TCH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) 1007818CH N/A N/A N/A UTTH4330UCH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) 1007801CH 28.50 (723.9) 18.00 (457.2) 5.69 (144.5) 5 UTH4330UCH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) 1007672CH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) UBTH4330TCH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) 1006344ACH 28.50 (723.9) 18.00 (457.2) 5.69 (144.5) 5 UTH4330TCH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) 1004984ACH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) UTH4300UCH 34.50 (876.3) 13.00 (330.2) 4.94 (125.5) 1004771BCH 36.62 (930.1) 15.00 (381.0) 5.68 (144.3) 5 UTH4300TCH 34.50 (876.3) 13.00 (330.2) 4.94 (125.5) UBTH7230ACH N/A N/A N/A 5 UH5300UKCCH 34.50 (876.3) 13.00 (330.2) 4.94 (125.5) UTH7233UCH 27.00 (685.8) 16.00 (406.4) 5.63 (143.0) UH43168UCPLCH 34.50 (876.3) 15.00 (381.0) 5.69 (144.5) UH43068TCPLCH 34.50 (876.3) 13.00 (330.2) 4.94 (125.5) UGTH4330UCH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) Notes 1 Aluminum enclosure. 2 Bolted in shield. 5 UGTH4330TCH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) 5 UFTH7330TCH 39.88 (1013.0) 20.00 (508.0) 6.50 (165.1) UFTH4330TCH 36.63 (930.4) 15.00 (381.0) 5.69 (144.5) V1-T5-16 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 5 5 5 UATH7330UFLCH 5 5 5 5.2 Metering Products Commercial Lever Bypass Sockets Approximate Dimensions in Inches (mm) 5 Commercial Lever Bypass, continued 5 Commercial Lever Bypass, continued Catalog Number Height Width Depth Catalog Number Height Width Depth UTE7213UFLCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UGTE4213BCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UETH72137UCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UGE4213CCCCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTE7213UCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UFTE7213BCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTE7213THLCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UATE7213TCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UBHRS212BCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UATE5213CCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UBEH7213TCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UATE4213UFLCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UFTE7213TCH 1 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UBGTE4203BCH 19.00 (482.6) 10.50 (266.7) 4.94 (125.5) UTE7213ZCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) 1009845ECH 64.00 (1625.6) 11.00 (279.4) 6.00 (152.4) UTE7213TCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) 1008801ECH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTE7213CFLCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) 1008832ECH 24.69 (627.1) 13.00 (330.2) 4.94 (125.5) UTE7213CCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) 1007944ECH 22.00 (558.8) 16.00 (406.4) 5.69 (144.5) UBTE7213BCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) 1007670ECH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTE7213BCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTTE7213TCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTE7210UCH 24.69 (627.1) 13.00 (330.2) 4.94 (125.5) UTE7203TCH 19.00 (482.6) 10.50 (266.7) 4.94 (125.5) UTE7203BCH 19.00 (482.6) 10.50 (266.7) 4.94 (125.5) Notes 1 Barrel lock. 2 TT = quadplex ground. UETH5213UCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTE5213TCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTTE5213TCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTE5213CCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTE5213BNDCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTE5213ZCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTE5213UFLCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTE5213CFLCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTE5213BCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTE5210CCH 20.13 (511.3) 13.00 (330.2) 4.94 (125.5) UTE5203BCH 19.00 (482.6) 10.50 (266.7) 4.94 (125.5) UTE4213ZCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UGTE4213CCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTE4213TCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTTE4213UCH 2 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTE4213CCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTE4213BCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UTE4203BCH 19.00 (482.6) 10.50 (266.7) 4.94 (125.5) UIH7213UCVCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UE7213CCCCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UE7213CCPLCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) UE7213BCPLCH 19.00 (482.6) 13.00 (330.2) 4.94 (125.5) 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-17 5.3 5 Metering Products Multiple Position Horizontal Ganged Sockets Multiple Position Horizontal Ganged Sockets Contents Description 5 Catalog Number Selection . . . . . . . . . . . . . . . . . . Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 5 5 5 5 5 5 5 5 5 5 Product Description ● ● 5 ● 5 ● 5 ● 5 ● 5 Available in 100A and 200A designs Available in 2-position through 6-position designs Multiple service design offerings Multiple line/load lug configurations Residential or lever bypass socket designs Multiple hub opening and closure plate sizes available 5 5 5 5 5 5 5 5 5 5 5 5 V1-T5-18 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Page V1-T5-19 V1-T5-20 V1-T5-23 Metering Products Multiple Position Horizontal Ganged Sockets 5.3 Catalog Number Selection 5 5 Single Meter Sockets 2R-6R and 2H-6H Group 5 UT 2R 1 1 2 1 B CH Note: The “U” prefix is always used first followed by other prefixes required in alphabetical order. Standard Prefixes A = Aluminum enclosure B = Barrel lock provision, for an exposed INNER-TITE or Brooks barrel lock; unit includes an internal lock receiver bracket F = Barrel lock with guard provision, for a lock guard INNER-TITE or Brooks barrel lock; unit includes an internal lock receiver bracket G = Grounded fifth terminal (9 o’clock position) H = Horn bypass I = Inhibitor installed in wire connectors M = Temporary meter cover (waxed cardboard) N = No sealing ring (applies only to ring style sockets) R = Ring style socket S = Aluminum screw type sealing ring (applies only to ring style sockets) T = Grounding connector (#14–#2 Cu) for triplex ground TT = Two grounding connectors (#14–#2 Cu) for quadplex ground U = UL label Z = 5/16-inch hex head connector screw in place of slotted (100A only) RS = 2R-6R = 2H-6H = H = 5 Standard Suffixes Product Group Residential service, single position Residential service, multiple position Commercial or residential service, multiple position Commercial or residential service, single position Ampere Rating 1 = 100A 2 = 200A 5 A = Solid top B = Small hub opening C = Small hub closing plate mounted L = 1.25-inch (31.8 mm) hub mounted M = 1.50-inch (38.1 mm) hub mounted N = 2.00-inch (50.8 mm) hub mounted P = 2.50-inch (63.5 mm) hub mounted T = Large hub opening hub U = Large hub cover plate hub mounted V = 2.50-inch (63.5 mm) large hub mounted Q = 3.00-inch (76.2 mm) large hub mounted R = 3.50-inch (88.9 mm) large hub mounted S = 4.00-inch (101.6 mm) large hub mounted Z = Large to small hub adapter mounted 5 5 5 5 5 Maximum Load Conductor 0 = 0.38-inch stud connectors 1 = #2/0 connectors 2 = #250 kcmil connectors 3 = #350 kcmil connectors 5 = #500 kcmil connectors 6 = #600 kcmil connectors 7 = #750 kcmil connectors 8 = Dual #500 kcmil connectors 5 5 5 5 Maximum Line Conductor 0 = 0.38-inch stud connectors 1 = #2/0 connectors 2 = #250 kcmil connectors 3 = #350 kcmil connectors 5 = #500 kcmil connectors 6 = #600 kcmil connectors 7 = #750 kcmil connectors 8 = Dual #500 kcmil connectors 5 5 5 5 Service Design 5 0 = Overhead 1 = Combination overhead/underground 2 = Underground, side wired 3 = Combination overhead/underground, side wired 4 = End feed 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-19 5.3 5 5 5 Metering Products Multiple Position Horizontal Ganged Sockets Product Selection UT2R2332BCH Horizontal Design—Multi Position Ringless Connections Ampere Rating Jaws Position Service Bypass Line Load Opening, Hub or Closure Plate Catalog Number 200 4 2 OH/UG Horn #6–350 kcmil #8–250 kcmil 5x5 hub opening 1004401BCH 5 200 4 3 OH/UG Horn #6–350 kcmil #8–250 kcmil 5x5 hub opening 1004404BCH 200 5 2 OH/UG Horn #6–350 kcmil #8–250 kcmil 5x5 hub opening 1004418ACH 5 200 4 2 OH/UG — 3/8-inch stud #8–250 kcmil 5x5 hub cover plate 1006737BCH 5 200 4 2 OH/UG Horn 3/8-inch stud #8–250 kcmil 5x5 hub opening 1007700CH 200 4 3 OH/UG Horn 3/8-inch stud #8–250 kcmil Hub opening 1007701CH 5 200 4 2 OH/UG Horn #6–350 kcmil #8–250 kcmil 5x5 hub cover plate 1008842CH 200 4 3 OH/UG Horn 1/0–500 kcmil cu/al #8–250 kcmil 5x5 hub cover plate 1008843CH 5 200 4 4 OH/UG Horn 1/0–500 kcmil cu/al #8–250 kcmil 5x5 hub cover plate 1008844CH 200 4 2 OH/UG Horn #6–350 kcmil #8–250 kcmil 5x5 hub cover plate 1008958CH 200 4 3 OH/UG Horn 1/0–500 kcmil cu/al #8–250 kcmil 5x5 hub cover plate 1008959CH 5 200 4 4 OH/UG Horn 1/0–500 kcmil cu/al #8–250 kcmil 5x5 hub cover plate 1008960CH 200 4 5 OH/UG Horn (2) 1/0–500 kcmil cu/al #8–250 kcmil (2) 5x5 hub cover plate 1009579ACH 5 200 4 4 OH/UG Horn 1/0–500 kcmil cu/al 5x5 hub opening U4R2352TDQCH 200 4 5 OH/UG Horn (2) 1/0–500 kcmil cu/al #8–250 kcmil (2) 5x5 hub opening U5R2392TTDQCH 5 200 4 6 OH/UG Horn (2) 1/0–500 kcmil cu/al #8–250 kcmil 5x5 hub opening (2) places U6R2392TTDQCH 5 200 4 4 OH/UG Horn 1/0–500 kcmil cu/al #8–250 kcmil 5x5 hub opening UBH4R2352TCH 200 4 2 OH/UG Horn #6–350 kcmil #8–250 kcmil 5x5 hub opening UBH2R2332TCH 200 4 3 OH/UG Horn #6–350 kcmil #8–250 kcmil 5x5 hub opening UBH3R2332TCH 200 4 4 OH/UG Horn 3/8-inch stud #8–250 kcmil 5x5 hub cover plate UEHT4R2302UCH 5 200 4 3 OH/UG Horn 3/8-inch stud #8–250 kcmil 5x5 hub cover plate UEHT3R2302UCH 5 200 4 2 OH/UG Horn 3/8-inch stud #8–250 kcmil 5x5 hub cover plate UEHT2R2302UCH 200 4 2 UG Horn #6–350 kcmil #8–250 kcmil Solid top UHI2R2332ACVCH 5 5 5 #8–250 kcmil 5 200 4 2 OH/UG Horn #6–350 kcmil #8–250 kcmil Hub opening UHI2R2332TCVCH 200 4 4 UG Horn 1/0–500 kcmil cu/al #8–250 kcmil Solid top UHI4R2352ACVCH 5 200 4 2 OH/UG Horn #6–350 kcmil #8–250 kcmil 5x5 hub cover plate UHTT2R2332UCH 5 200 4 2 OH/UG Horn #6–350 kcmil #8–250 kcmil 5x5 hub opening UHT2R2332TCH 200 4 3 OH/UG Horn #6–350 kcmil #8–250 kcmil 5x5 hub opening UHT3R2332TCH 5 200 4 3 OH/UG Horn 1/0–500 kcmil cu/al #8–250 kcmil 5x5 hub cover plate UHT3R2352UCH 200 4 4 OH/UG Horn 1/0–500 kcmil cu/al #8–250 kcmil 5x5 hub opening UHT4R2352TCH 5 200 4 4 OH/UG — 1/0–500 kcmil cu/al #8–250 kcmil 5x5 hub cover plate UT4R2352UFLCH 200 4 4 OH/UG Horn 1/0–500 kcmil cu/al #8–250 kcmil 5x5 hub cover plate UHT4R2352UCH 200 5 2 OH/UG Lever 1/0–500 kcmil cu/al #6–350 kcmil 5x5 hub opening UT2H52353TCH 5 200 4 2 OH/UG Horn #6–350 kcmil #8–250 kcmil 5x5 hub cover plate UHT2R2332UCH 200 4 2 OH/UG — #6–350 kcmil #8–250 kcmil 3-5/16 hub opening UT2R2332BCH 5 200 4 2 OH/UG — #6–350 kcmil #8–250 kcmil 5x5 hub opening UAT2R2332TCH 1 200 4 2 OH/UG — #6–350 kcmil #8–250 kcmil 5x5 hub opening UT2R2332TCH 5 200 4 2 OH/UG — #6–350 kcmil #8–250 kcmil 5x5 hub opening U2R2332TCPLCH 5 200 4 2 OH/UG — #6–350 kcmil #8–250 kcmil 5x5 hub cover plate U2R2332UCPLCH 200 4 2 OH/UG Horn #6–350 kcmil #8–250 kcmil 5x5 hub opening U2R2332TDQCH 200 4 2 OH/UG — #6–350 kcmil #8–250 kcmil 5x5 hub cover plate UT2R2332UCH 200 4 3 OH/UG Horn #6–350 kcmil #8–250 kcmil Large 5X5 hub opening U3R2332TDQCH 5 5 5 Notes 1 Aluminum enclosure. 5 For dimensions, see Pages V1-T5-23 and V1-T5-24. V1-T5-20 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Multiple Position Horizontal Ganged Sockets UT2R1121BCH 5.3 Horizontal Design—Multi Position Ringless, continued Connections Ampere Rating Jaws Position Service Bypass Line 200 4 3 OH/UG Lever 1/0–500 kcmil cu/al 5 Load Opening, Hub or Closure Plate Catalog Number #6–350 kcmil 5x5 hub opening UT3H42353TCH 200 5 3 OH/UG Lever 1/0–500 kcmil cu/al #6–350 kcmil 5x5 hub opening UT3H52353TCH 200 7 3 OH/UG Lever 1/0–500 kcmil cu/al #6–350 kcmil 5x5 hub cover plate UT3H72353UHLCH 200 4 3 OH/UG — #6–350 kcmil #8–250 kcmil 5x5 hub opening UT3R2332TCH 200 4 3 OH/UG — #6–350 kcmil #8–250 kcmil 5x5 hub cover plate UT3R2332UCH 200 4 3 OH/UG — 1/0–500 kcmil cu/al #8–250 kcmil 5x5 hub opening UT3R2352TCH 200 4 4 OH/UG — 1/0–500 kcmil cu/al #8–250 kcmil 5x5 hub opening UT4R2352TCH 200 4 5 OH/UG Horn (2) 1/0–500 kcmil cu/al #8–250 kcmil 5x5 hub opening (in two places) UHT5R2392TTCH 200 4 5 OH/UG — (2) 1/0–500 kcmil cu/al #8–250 kcmil 5x5 hub opening (in two places) UT5R2392TTCH 200 7 5 OH/UG Lever Dual 1/0–500 kcmil (2) 5X5 hub closure plates UT5H72393UUHLCH 200 4 6 OH/UG Horn (2) 1/0–500 kcmil cu/al #8–250 kcmil #6–350 kcmil 5x5 hub opening (in two places) UHT6R2392TTCH 200 4 6 OH/UG — (2) 1/0–500 kcmil cu/al #8–250 kcmil 5x5 hub opening (in two places) UT6R2392TTCH 200 4 6 OH/UG — (2) 1/0–500 kcmil cu/al #8–250 kcmil 5x5 closure plate (in two places) UT6R2392UUFLCH 200 7 6 OH/UG Lever Dual 1/0–500 kcmil 5x5 closure plate (in two places) UT6H72393UUHLCH 200 4 6 OH/UG Horn (2) 1/0–500 kcmil cu/al #8–250 kcmil 5x5 hub opening (in two places) UHT6R2392TTCH 150 4 2 OH/UG Horn #6–350 kcmil #8–250 kcmil 3-5/16 hub opening U2R5432BDQCH 150 4 5 OH/UG — #6–350 kcmil #8–250 kcmil 3-5/16 hub opening (in two places) UT5R5632BCH 100 4 6 OH/UG — #6–350 kcmil #8–2/0 cu/al 3-5/16 hub opening UT6R1131BCH 100 4 2 OH/UG Horn #6–250 kcmil #8–2/0 cu/al 5x5 hub opening 1004426ACH 100 4 2 OH/UG Horn #6–250 kcmil #8–2/0 cu/al 3-5/16 hub opening 1008951CH 100 4 3 OH/UG Horn #6–250 kcmil #8–2/0 cu/al 3-5/16 hub opening 1008952CH 100 4 2 OH/UG Horn #6–250 kcmil #8–2/0 cu/al 3-5/16 hub cover plate 1009693CH 100 4 3 OH/UG Horn #6–250 kcmil #8–2/0 cu/al 3-5/16 hub cover plate 1009694CH 100 4 4 OH/UG Horn #6–250 kcmil #8–2/0 cu/al 3-5/16 hub cover plate 1009695CH 100 4 5 OH/UG Horn #6–250 kcmil #8–2/0 cu/al 3-5/16 hub cover plate 1009696CH 100 4 6 OH/UG — #6–350 kcmil #8–2/0 cu/al 3-5/16 hub cover plate UATZ6R1131CFLCH 1 100 4 2 OH/UG Horn #6–250 kcmil #8–2/0 cu/al 3-5/16 hub opening UBH2R1121BCH 100 4 3 OH/UG Horn #6–250 kcmil #8–2/0 cu/al 3-5/16 hub opening UBH3R1121BCH 100 4 4 OH/UG Horn #6–250 kcmil #8–2/0 cu/al 3-5/16 hub opening UBH4R1121BCH 100 4 2 OH/UG Horn #6–250 kcmil #8–2/0 cu/al 3-5/16 hub opening UHT2R1121BCH 100 4 4 OH/UG — #6–250 kcmil #8–2/0 cu/al 3-5/16 hub opening UT4R1121BCH 100 4 4 OH/UG — #6–250 kcmil #8–2/0 cu/al 3-5/16 closure plate UT4R1121CCH 100 4 4 OH/UG Horn #6–250 kcmil #8–2/0 cu/al 3-5/16 hub opening UHT4R1121BCH 100 4 5 OH/UG Horn #6–250 kcmil #8–2/0 cu/al 3-5/16 hub opening UHT5R1121BCH 100 4 5 OH/UG — #6–250 kcmil #8–2/0 cu/al 3-5/16 hub opening UT5R1121BCH 100 4 5 OH/UG — #6–250 kcmil #8–2/0 cu/al 3-5/16 closure plate UT5R1121CCH 100 4 2 OH/UG — #6–250 kcmil #8–2/0 cu/al 3-5/16 hub opening UT2R1121BCH 100 4 2 OH/UG — #6–250 kcmil #8–2/0 cu/al 3-5/16 closure plate UT2R1121CCH 100 4 2 OH/UG Horn #6–250 kcmil #8–2/0 cu/al 3-5/16 closure plate UHT2R1421CCH 100 4 2 OH/UG — #6–250 kcmil #8–2/0 cu/al 3-5/16 hub opening 3-5/16 hub cover plate UT2R1421BCH 100 4 3 OH/UG Horn #6–250 kcmil #8–2/0 cu/al 3-5/16 hub opening UHT3R1121BCH 100 4 3 OH/UG — #6–250 kcmil #8–2/0 cu/al 3-5/16 hub opening UT3R1121BCH #6–350 kcmil 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Notes 1 Aluminum enclosure. 5 For dimensions, see Pages V1-T5-23 and V1-T5-24. 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-21 5.3 Metering Products Multiple Position Horizontal Ganged Sockets 5 Horizontal Design—Multi Position Ring Type 5 Ampere Rating Jaws Position Service Bypass Line Load Opening, Hub or Closure Plate Catalog Number 5 200 4 2 OH/UG — 1/0–500 kcmil cu/al #8–250 kcmil 5x5 hub opening U2R2352TCRCH 200 4 2 OH/UG — #6–350 kcmil #8–250 kcmil 5x5 hub cover plate URT2R2332UCH 5 200 5 4 OH/UG — 1/0–500 kcmil cu/al #8–250 kcmil Large 5x5 hub opening U4R2352TCRCH 125 5 2 OH — #8–350 kcmil #8–2/0 cu/al Hub opening U2V1031BCRCH 1 5 125 5 3 OH — #8–350 kcmil #8–2/0 cu/al Hub opening U3V1031BCRCH 1 5 100 5 2 OH/UG — #6–250 kcmil #8–2/0 cu/al 3-5/16 opening U2R1121BCRCH 100 5 3 OH/UG — #6–250 kcmil #8–2/0 cu/al 3-5/16 opening U3R1121BCRCH 100 5 4 OH/UG — #6–250 kcmil #8–2/0 cu/al 3-5/16 opening U4R1121BCRCH 100 5 5 OH/UG — #6–250 kcmil #8–2/0 cu/al 3-5/16 opening U5R1121BCRCH 5 5 Connections Notes 1 Vertical gang. 5 For dimensions, see Pages V1-T5-23 and V1-T5-24. 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 V1-T5-22 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Multiple Position Horizontal Ganged Sockets 5.3 Dimensions 5 Approximate Dimensions in Inches (mm) 5 Horizontal Design—Multi Position Ringless Horizontal Design—Multi Position Ringless, continued Catalog Number Height Width Depth Catalog Number Height Width Depth 1004401BCH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) UT3R2332TCH 14.13 (358.9) 32.47 (824.7) 5.38 (136.7) 1004404BCH 14.13 (358.9) 32.47 (824.7) 5.38 (136.7) UT3R2332UCH 14.13 (358.9) 32.47 (824.7) 5.38 (136.7) 1004418ACH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) UT3R2352TCH 14.13 (358.9) 40.63 (1032.0) 5.38 (136.7) 1006737BCH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) UT4R2352TCH 14.13 (358.9) 40.63 (1032.0) 5.38 (136.7) 1007700CH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) UHT5R2392TTCH 14.13 (358.9) 54.78 (1391.4) 5.38 (136.7) 1007701CH 14.13 (358.9) 32.47 (824.7) 5.38 (136.7) UT5R2392TTCH 14.13 (358.9) 54.78 (1391.4) 5.38 (136.7) 1008842CH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) UT5H72393UUHLCH 29.56 (750.8) 72.15 (1832.6) 6.00 (152.4) 1008843CH 14.13 (358.9) 32.47 (824.7) 5.38 (136.7) UHT6R2392TTCH 14.13 (358.9) 62.94 (1598.7) 5.38 (136.7) 1008844CH 14.13 (358.9) 40.63 (1032.0) 5.38 (136.7) UT6R2392TTCH 14.13 (358.9) 62.94 (1598.7) 5.38 (136.7) 1008958CH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) UT6R2392UUFLCH 14.13 (358.9) 62.94 (1598.7) 5.38 (136.7) 1008959CH 14.13 (358.9) 32.47 (824.7) 5.38 (136.7) UT6H72393UUHLCH 23.56 (598.4) 83.28 (2115.3) 6.00 (152.4) 1008960CH 14.13 (358.9) 40.63 (1032.0) 5.38 (136.7) UHT6R2392TTCH 14.13 (358.9) 62.94 (1598.7) 5.38 (136.7) 1009579ACH 14.13 (358.9) 54.78 (1391.4) 5.38 (136.7) U2R5432BDQCH 14.13 (358.9) 20.16 (512.1) 5.38 (136.7) U4R2352TDQCH 14.13 (358.9) 40.63 (1032.0) 5.38 (136.7) UT5R5632BCH 14.13 (358.9) 48.63 (1235.2) 5.38 (136.7) U5R2392TTDQCH 14.13 (358.9) 62.94 (1598.7) 5.38 (136.7) UT6R1131BCH 14.13 (358.9) 56.93 (1446.0) 4.50 (114.3) U6R2392TTDQCH 14.13 (358.9) 62.94 (1598.7) 5.38 (136.7) 1004426ACH 14.13 (358.9) 24.31 (617.5) 4.50 (114.3) UBH4R2352TCH 14.13 (358.9) 40.63 (1032.0) 5.38 (136.7) 1008951CH 14.13 (358.9) 24.31 (617.5) 4.50 (114.3) UBH2R2332TCH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) 1008952CH 14.13 (358.9) 32.47 (824.7) 4.50 (114.3) UBH3R2332TCH 14.13 (358.9) 32.47 (824.7) 5.38 (136.7) 1009693CH 14.13 (358.9) 24.16 (613.7) 5.38 (136.7) UEHT4R2302UCH 14.13 (358.9) 40.63 (1032.0) 5.38 (136.7) 1009694CH 14.13 (358.9) 32.31 (820.7) 5.38 (136.7) UEHT3R2302UCH 14.13 (358.9) 32.47 (824.7) 5.38 (136.7) 1009695CH 14.13 (358.9) 49.94 (1268.5) 5.38 (136.7) UEHT2R2302UCH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) 1009696CH 14.13 (358.9) 48.63 (1235.2) 5.38 (136.7) UHI2R2332ACVCH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) UATZ6R1131CFLCH 14.13 (358.9) 56.94 (1446.3) 4.50 (114.3) UHI2R2332TCVCH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) UBH2R1121BCH 14.13 (358.9) 24.94 (633.5) 4.50 (114.3) UHI4R2352ACVCH 14.13 (358.9) 40.63 (1032.0) 5.38 (136.7) UBH3R1121BCH 14.13 (358.9) 32.47 (824.7) 4.50 (114.3) UHTT2R2332UCH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) UBH4R1121BCH 14.13 (358.9) 40.63 (1032.0) 4.50 (114.3) UHT2R2332TCH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) UHT2R1121BCH 14.13 (358.9) 24.31 (617.5) 4.50 (114.3) UHT3R2332TCH 14.13 (358.9) 32.94 (836.7) 5.38 (136.7) UT4R1121BCH 14.13 (358.9) 40.63 (1032.0) 4.50 (114.3) UHT3R2352UCH 14.13 (358.9) 32.47 (824.7) 5.38 (136.7) UT4R1121CCH 14.13 (358.9) 40.63 (1032.0) 4.50 (114.3) UHT4R2352TCH 14.13 (358.9) 40.63 (1032.0) 5.38 (136.7) UHT4R1121BCH 14.13 (358.9) 40.63 (1032.0) 4.50 (114.3) UT4R2352UFLCH 14.13 (358.9) 40.63 (1032.0) 5.38 (136.7) UHT5R1121BCH 14.13 (358.9) 48.78 (1239.0) 4.50 (114.3) UHT4R2352UCH 14.13 (358.9) 40.63 (1032.0) 5.38 (136.7) UT5R1121BCH 14.13 (358.9) 48.78 (1239.0) 4.50 (114.3) UT2H52353TCH 23.56 (598.4) 32.78 (832.6) 6.00 (152.4) UT5R1121CCH 14.13 (358.9) 48.78 (1239.0) 4.50 (114.3) UHT2R2332UCH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) UT2R1121BCH 14.13 (358.9) 24.31 (617.5) 4.50 (114.3) 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) UT2R1121CCH 14.13 (358.9) 24.31 (617.5) 4.50 (114.3) UT2R2332BCH 1 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) UHT2R1421CCH 14.13 (358.9) 20.16 (512.1) 5.38 (136.7) UT2R2332TCH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) UT2R1421BCH 14.13 (358.9) 20.16 (512.1) 5.38 (136.7) U2R2332TCPLCH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) UHT3R1121BCH 14.13 (358.9) 32.47 (824.7) 4.50 (114.3) U2R2332UCPLCH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) UT3R1121BCH 14.13 (358.9) 32.47 (824.7) 4.50 (114.3) U2R2332TDQCH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) UT2R2332UCH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) Note 1 Aluminum enclosure. U3R2332TDQCH 14.13 (358.9) 32.47 (824.7) 5.38 (136.7) UT3H42353TCH 23.56 (598.4) 43.91 (1115.3) 6.00 (152.4) UT3H52353TCH 23.56 (598.4) 43.91 (1115.3) 6.00 (152.4) UT3H72353UHLCH 23.56 (598.4) 43.91 (1115.3) 5.38 (136.7) UAT2R2332TCH Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 V1-T5-23 5.3 5 5 5 Metering Products Multiple Position Horizontal Ganged Sockets Approximate Dimensions in Inches (mm) Horizontal Design—Multi Position Ring Type Catalog Number Height Width Depth U2R2352TCRCH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) URT2R2332UCH 14.13 (358.9) 24.31 (617.5) 5.38 (136.7) 5 U4R2352TCRCH 14.13 (358.9) 48.00 (1219.2) 5.38 (136.7) U2V1031BCRCH 1 8.00 (203.2) 25.63 (650.9) 4.38 (111.1) 5 U3V1031BCRCH 1 8.00 (203.2) 35.88 (911.2) 4.38 (111.1) U2R1121BCRCH 14.13 (358.9) 28.00 (711.2) 4.50 (114.3) 5 U3R1121BCRCH 14.13 (358.9) 38.00 (965.2) 4.50 (114.3) 5 U4R1121BCRCH 14.13 (358.9) 48.00 (1219.2) 4.50 (114.3) U5R1121BCRCH 14.13 (358.9) 58.00 (1473.2) 4.50 (114.3) 5 5 Note 1 Vertical gang. 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 V1-T5-24 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Instrument Rated Sockets Instrument Rated Sockets 5.4 Contents Description Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page V1-T5-26 V1-T5-26 5 5 5 5 5 5 5 5 5 5 5 Product Description ● ● ● ● ● ● ● 5 Available in 6, 7, 8 and 13 terminal designs 20A ratings standard Multiple service designs available (overhead, underground, overhead/ underground) Multiple hub opening and closure plate sizes available 600 Vac rated Single cover/dual cover availability Provisional test switches and factory-installed test switch designs available 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-25 5.4 5 5 Metering Products Instrument Rated Sockets Product Selection USTS132CCH Instrument Rated Sockets Ampere Rating Jaws Service Opening, Hub or Closure Plate Catalog Number 20 13 terminal UG Solid top USTH131A123CH 5 20 13 terminal OH/UG 3-5/16 hub cover plate USTS131B102CH 5 20 13 terminal OH/UG 3-5/16 hub cover plate USTS132B101CH 20 13 terminal OH/UG 3-5/16 hub cover plate USTS132CCH 5 20 13 terminal OH/UG 1-inch bolt-on hub 1008694ACH 20 8 terminal OH/UG 1-inch bolt-on hub 1008695ACH 5 20 13 terminal N/A N/A 1007003BCH 20 13 terminal Solid top and bottom Solid top 1007003CCH 5 20 13 terminal OH/UG 3-5/16 hub cover plate USTL131C207CH 20 13 terminal OH/UG Hub opening USTS131BCH 5 20 13 terminal OH/UG 1-1/4-inch bolt-on hub USTS131L143CH 20 13 terminal N/A N/A USTS132BCH 20 6 terminal OH/UG Hub opening USTS61B138CH 5 5 5 20 6 terminal OH/UG Hub opening UST61BCH 20 8 terminal OH/UG Hub opening USTS82B166CH 20 8 terminal N/A Solid top and bottom 1007361BCH N/A N/A N/A N/A 1008539CH 5 20 13 terminal OH/UG 3-5/16 hub cover plate UASTS131C226CH 20 13 terminal OH 3-5/16 hub cover plate 1004671CH 5 20 7 terminal OH 3-5/16 hub cover plate ULTS131CCH 20 6 terminal UG Solid top STL61A433CH 20 13 terminal UG Solid top STL131A120CH 5 5 5 Dimensions 5 Approximate Dimensions in Inches (mm) 5 Instrument Rated Sockets Catalog Number Height Width Depth 5 USTH131A123CH 20.00 (304.8) 12.00 (304.8) 4.36 (110.7) USTS131B102CH 20.00 (304.8) 12.00 (304.8) 4.36 (110.7) 5 USTS132B101CH 20.00 (304.8) 12.00 (304.8) 4.36 (110.7) 5 USTS132CCH 20.00 (304.8) 12.00 (304.8) 4.36 (110.7) 1008694ACH 20.00 (304.8) 12.00 (304.8) 4.36 (110.7) 5 1008695ACH 20.00 (304.8) 12.00 (304.8) 4.36 (110.7) 1007003BCH N/A N/A N/A 5 1007003CCH 16.50 (419.1) 14.00 (355.6) 3.50 (88.9) USTL131207CH 20.00 (304.8) 12.00 (304.8) 4.35 (110.5) 5 USTS131BCH 20.00 (304.8) 12.00 (304.8) 4.35 (110.5) USTS131L143CH 20.00 (304.8) 12.00 (304.8) 4.35 (110.5) 5 USTS132BCH N/A N/A N/A 5 USTS61B138CH 20.00 (304.8) 12.00 (304.8) 4.35 (110.5) UST61BCH 20.00 (304.8) 12.00 (304.8) 4.35 (110.5) 5 USTS82B166CH 20.00 (304.8) 12.00 (304.8) 4.35 (110.5) 1007361BCH 16.50 (419.1) 14.00 (355.6) 3.50 (88.9) 5 1008539CH N/A N/A N/A UASTS131C226CH 20.00 (304.8) 12.00 (304.8) 4.35 (110.5) 5 1004671CH 17.00 (431.8) 10.00 (254.0) 5.00 (127.0) ULTS131CCH 22.00 (558.8) 12.00 (304.8) 4.94 (125.5) 5 V1-T5-26 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Residential Pedestals Residential Pedestals 5.5 Contents Description Product Selection . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page V1-T5-28 V1-T5-28 5 5 5 5 5 5 5 5 5 5 5 Product Description ● ● ● ● ● 5 Available in 100A, 200A, 300A and 320A designs Available in 4- or 5-jaw configurations Underground service design is standard Bypass options (lever, horn) are available Solid top designs 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-27 5.5 5 5 Metering Products Residential Pedestals Product Selection UHTRP242363CH 5 5 Residential Pedestals Connections Ampere Rating Jaws Service Bypass Line Load Opening, Hub or Closure Plate Catalog Number Solid top 1008847CH 320 4 UG — 3/8-inch studs 3/8-inch studs 320 4 UG Lever #6–350 kcmil line and line neutral 2/0–250 kcmil load and load neutral Solid top 300 4 UG Lever #6–350 kcmil line and line neutral 2/0–250 kcmil load and load neutral Solid top 5 200 4 UG Horn 4/0 compression (line) 2/0 compression (neutral) #6–250 kcmil load and load neutral Solid top 1006388CH 5 200 4 UG Horn #8–350 kcmil #8–350 kcmil Solid top UHTRP242363CH 200 4 UG Horn #6–350 kcmil line and line neutral #6–250 kcmil load neutral Solid top 1008846CH 5 200 4 UG Horn #6–350 kcmil line and line neutral #6–250 kcmil load neutral N/A 1008961CH 5 200 5 N/A N/A N/A N/A N/A 1008966CH 200 4 UG — #6–350 kcmil line and line neutral #6–350 kcmil load and load neutral Solid top 1009264CH 5 200 4 UG — 4/0 compression (line) 2/0 compression (neutral) #6–350 kcmil load and load neutral Solid top 1009265CH 5 100 4 UG — #6–350 kcmil line and line neutral #6–250 kcmil load neutral 1009078CH 5 5 Pedestal Extension Kits 5 Connections Line Load Catalog Number 5 Pedestal extension kit for 1008846CH Pedestal extension kit for 1008846CH 1009021CH 1009022CH 5 5 1009026CH Dimensions 5 Approximate Dimensions in Inches (mm) 5 Residential Pedestals 5 Catalog Number Height Width Depth 1008847CH 58.00 (1473.2) 12.97 (329.4) 4.93 (125.2) 1009017CH 1 63.00 (1600.2) 12.96 (329.2) 4.93 (125.2) 1006388CH 61.00 (1549.4) 8.96 (227.6) 4.93 (125.2) UHTRP242363CH 62.63 (1590.8) 8.97 (227.8) 4.94 (125.5) 1008846CH 70.00 (1778.0) 11.00 (279.4) 6.00 (152.4) 5 1008961CH 69.93 (1776.2) N/A 6.00 (152.4) 5 1008966CH N/A N/A N/A 1009264CH 74.00 (1879.6) 8.96 (227.6) 4.93 (125.2) 1009265CH 74.00 (1879.6) 8.97 (227.8) 4.94 (125.5) 1009078CH 69.93 (1776.2) 11.00 (279.4) 6.00 (152.4) 5 5 5 5 5 5 5 5 Pedestal Extension Kits Catalog Number Height Width Depth 1009021CH 18.00 (457.2) 11.00 (279.4) 6.00 (152.4) 1009022CH 18.00 (457.2) 12.96 (329.2) 4.93 (125.2) 1009026CH 30.00 (762.0) 12.96 (329.2) 4.93 (125.2) Note 1 200A breakers. 5 V1-T5-28 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Solid top 1009017CH 1 Metering Products Accessories and Cross-Reference 5.6 Product Description 5 This section will help you better understand the features and benefits of the 125A and 200A Eaton designed meter socket. 5 5 5 Features and Benefits Construction Features 5 200A Ringless Block Assembly With Horn Bypass 5 5 5 1. High strength, glass-filled meter block assembly, lay-in connectors with captive slide nut and screw. 5 5 3. Extruded neutral lug with integral triplex ground and quadplex ground provision. 5 5 5 5 2. 100% plated copper alloy meter jaw with reinforcing spring clip and meter guide. 4. Bridge and meter supports are 100% zinc chromate plated. 5. Fifth terminal locating hole in 9 o’clock position. 9. Extra rigid meter support for ringless sockets. 6. Triplex ground is a standard feature. 10. Optional, integral horn bypass extruded on slide nut. Horn is ribbed for secure attachment to utility bypass jumpers. Field-installable horn bypass kit available. 7. Quadplex ground provision. 8. Durable “four-point” bridge mounting (2 top, 2 bottom). 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-29 5.6 5 5 Metering Products Accessories and Cross-Reference Product Selection Meter Socket Accessories 5 Description Part Number 5 Hub closure plate meter socket accessories ARP00002CHB Clam shell hub closure plate meter socket accessories ARP00002CHBCS 5 1-inch hub closure plate meter socket accessories ARP00003CH1 Clam shell 1-inch hub closure plate—small opening ARP00003CH1CS 5 1-1/4-inch hub closure plate meter socket accessories ARP00004CH12 Clam shell 1-1/4-inch hub closure plate—small opening ARP00004CH12CS 1-1/2-inch hub closure plate meter socket accessories ARP00005CH15 5 Clam shell 1-1/2-inch hub closure plate—small opening ARP00005CH15CS 2-inch hub closure plate meter socket accessories ARP00006CH2 5 2-1/2-inch hub for meter socket accessories ARP00007CH25 Clam shell 2-1/2-inch hub for meter socket accessories ARP00007CH25CS 5 Aluminum hub closure plate for single sockets ARP00008CH 5 Hub adapter from large opening to small opening ARP00015CHAP Large hub cover plate ARP00016CHB 2-inch hub with large diameter opening ARP00017CH2 2.5-inch hub with large diameter opening ARP00018CH25 5 3-inch hub ARP00019CH3 5 3-1/2-inch hub for meter sockets ARP00020CH35 4-inch hub ARP00021CH4 5 Screw sealing ring for single meter sockets ARP00027CH Fifth jaw kit ARP00035CHJ 5 #6–350 kcmil lug kit for single sockets—3/8-inch stud ARP00119CH 5 #4–600 kcmil connector for single position meter sockets ARP00129CH Fifth jaw for bolt on meter ARP00326CH 5 #6–350 kcmil double barrel lug kit ARP00427CH Neutral Insulating Kit ARP00759CH 5 100A meter socket horn cap assembly kit ARP00777CH Fifth jaw kit for 320A offset socket ARP00862CH HQ anti-inversion clip for single meter sockets ARP00984CH 5 Fifth jaw for Chicago and Wisconsin pedestal ARP01085CH 350 kcmil BNS cap assembly kit for meter sockets ARP01226CH 5 Right hand block assembly with Z Bar ARP01258CH Left hand block assembly with Z Bar ARP01414CH Meter pack trough closure plate kit ARP01565CH 2/0 connector kit for MBB and MBP socket breaker ARP01612CH 5 5 5 5 5 5 5 5 5 5 5 V1-T5-30 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Accessories and Cross-Reference 5.6 Cross-Reference 5 5 Meter Sockets 5 Manufacturer Eaton Milbank Description Part Number Part Number 125A, OH/UG, ringless, triplex ground, hub opening UTRS101BE U7487-RL-TG 125A, OH/UG, ringless, triplex ground, hub cover plate UTRS101CE U7487-XL-TG 125A, OH/UG, ringless, triplex ground, hub opening, horn bypass UHTRS101BE U7487-RL-TG-KK 125A, OH/UG, ringless, triplex ground, hub cover plate, horn bypass UHTRS101CE U7487-XL-TG-KK 125A, OH/UG, ringless, triplex ground, hub opening, fifth terminal UTRS101BCH + MSR5TK U7487-RL-TG-5T 125A, OH/UG, ringless, triplex ground, hub cover plate, fifth terminal UTRS101CE + MSR5TK U7487-XL-TG-5T 125A, OH/UG, ringless, triplex ground, hub opening, horn bypass, fifth terminal UHTRS101BCH + MSR5TK U7487-RL-TG-KK-5T 125A, OH/UG, ringless, triplex ground, hub cover plate, horn bypass, fifth terminal UGHTRS101CE + MSR5TK U7487-XL-TG-KK-5T 200A, OH, ringless, triplex ground, hub opening UTRS202BCH U7021-RL-TG 200A, OH, ringless, triplex ground, hub cover plate UTRS202CCH U7021-XL-TG 200A, OH, ringless, triplex ground, hub opening, horn bypass UHTRS202BCH U7021-RL-TG-KK 200A, OH, ringless, triplex ground, hub cover plate, horn bypass UHTRS202CCH U7021-RL-TG-KK 200A, OH, ringless, triplex ground, hub opening, fifth terminal UGTRS202BCH U7021-RL-TG-5T 200A, OH, ringless, triplex ground, hub cover plate, fifth terminal UGTRS202CCH U7021-XL-TG-5T 200A, OH, ringless, triplex ground, hub opening, horn bypass, fifth terminal UGHTRS202BCH U7021-RL-TG-KK-5T 200A, OH, ringless, triplex ground, hub cover plate, horn bypass, fifth terminal UGHTRS202CCH U7021-RL-TG-KK-5T 200A, OH/UG, ringless, triplex ground, hub opening, 250 kcmil lugs UTRS212BCH No cross (no 250 kcmil lugs) 200A, OH/UG, ringless, triplex ground, hub cover plate, 250 kcmil lugs UTRS212CCH No cross (no 250 kcmil lugs) 200A, OH/UG, ringless, triplex ground, hub opening, horn bypass, 250 kcmil lugs UHTRS212BCH No cross (no 250 kcmil lugs) 200A, OH/UG, ringless, triplex ground, hub cover plate, horn bypass, 250 kcmil lugs UHTRS212CCH No cross (no 250 kcmil lugs) 200A, OH/UG, ringless, triplex ground, hub opening, fifth terminal, 250 kcmil lugs UGTRS212BCH No cross (no 250 kcmil lugs) 200A, OH/UG, ringless, triplex ground, hub cover plate, fifth terminal, 250 kcmil lugs UGTRS212CCH No cross (no 250 kcmil lugs) 200A, OH/ UG, ringless, triplex ground, hub opening, horn bypass, fifth terminal, 250 kcmil lugs UGHTRS212BCH No cross (no 250 kcmil lugs) 200A, OH/UG, ringless, triplex ground, hub cover plate, horn bypass, fifth terminal, 250 kcmil lugs UGHTRS212CCH No cross (no 250 kcmil lugs) 200A, OH/UG, ringless, triplex ground, hub opening, 350 kcmil lugs UTRS213BE U7040-RL-TG 200A, OH/UG, ringless, triplex ground, hub cover plate, 350 kcmil lugs UTRS213CE U7040-XL-TG 200A, OH/UG, ringless, triplex ground, hub opening, horn bypass, 350 kcmil lugs UHTRS213BE U7040-RL-TG-KK 200A, OH/UG, ringless, triplex ground, hub cover plate, horn bypass, 350 kcmil lugs UHTRS213CE U7040-XL-TG-KK 200A, OH/UG, ringless, triplex ground, hub opening, fifth terminal, 350 kcmil lugs UGTRS213BE U7040-RL-TG-5T 200A, OH/UG, ringless, triplex ground, hub cover plate, fifth terminal, 350 kcmil lugs UGTRS213CE U7040-XL-TG-5T 200A, OH/ UG, ringless, triplex ground, hub opening, horn bypass, fifth terminal, 350 kcmil lugs UGHTRS213BE U7040-RL-TG-KK-5T 200A, OH/UG, ringless, triplex ground, hub cover plate, horn bypass, fifth terminal, 350 kcmil lugs UGHTRS213CE U7040-XL-TG-KK-5T 200A, UG, ringless, triplex ground, solid top UTRS223ACH U1980-0-TG 200A, UG, ringless, triplex ground, solid top, horn bypass UHTRS223ACH U1980-0-TG-KK 200A, UG, ringless, triplex ground, solid top, fifth terminal UGTRS223ACH U1980-O-TG-5T 200A, UG, ringless, triplex ground, solid top, horn bypass, fifth terminal UGHTRS223ACH U1980-O-TG-KK-5T 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-31 5.6 5 5 5 Metering Products Accessories and Cross-Reference Lever Bypass Manufacturer Eaton Milbank Description Part Number Part Number U9800-RL 200A, OH, lever bypass, 4 terminal, small hub opening UTE4203BCH 200A, OH, lever bypass, 4 terminal, hub cover plate UTH4203CCH U9800-XL 200A, OH, lever bypass, 4 terminal, large hub opening UTH4203TCH U9800-R 5 200A, OH, lever bypass, 4 terminal, large hub cover plate UTH4203UCH U9800-X 5 200A, OH, lever bypass, 5 terminal, small hub opening UTE5203BCH U4550-RL 200A, OH, lever bypass, 5 terminal, hub cover plate UTH5203CCH U4550-XL 200A, OH, lever bypass, 5 terminal, large hub opening UTH5203TCH U9559-R 200A, OH, lever bypass, 5 terminal, large hub cover plate UTH5203UCH U9550-X 5 5 5 5 200A, OH, lever bypass, 7 terminal, small hub opening UTE7203BCH U4701-RL 200A, OH, lever bypass, 7 terminal, hub cover plate UTH7203CCH U4701-XL 200A, OH, lever bypass, 7 terminal, large hub opening UTE7203TCH U4701-R 5 200A, OH, lever bypass, 7 terminal, large hub cover plate UTH7203UCH U4701-X 200A, OH/UG, lever bypass, 4 terminal, small hub opening UTE4213BCH U9801-RL 5 200A, OH/UG, lever bypass, 4 terminal, hub cover plate UTE4213CCH U9801-XL 200A, OH/UG, lever bypass, 4 terminal, large hub opening UTE4213TCH U9801-R 5 200A, OH/UG, lever bypass, 4 terminal, large hub cover plate UTH4213UCH U9801-XL 5 200A, OH/UG, lever bypass, 4 terminal, large hub opening with adapter plate UTE4213ZCH U9801-RRL 200A, OH/UG, lever bypass, 4 terminal, large hub opening with adapter and cover plate UTH4213YCH U9801-RXL 5 200A, OH/UG, lever bypass, 5 terminal, small hub opening UTE5213BCH U4551-RL U4551-XL 200A, OH/UG, lever bypass, 5 terminal, hub cover plate UTE5213CCH 200A, OH/UG, lever bypass, 5 terminal, large hub opening UTE5213TCH U9551-R 200A, OH/UG, lever bypass, 5 terminal, large hub cover plate UTH5213UCH U9551-X 200A, OH/UG, lever bypass, 5 terminal, large hub opening with adapter plate UTE5213ZCH U9551-RRL or U4551-RRL 5 200A, OH/UG, lever bypass, 5 terminal, large hub opening with adapter and cover plate UTH5213YCH U9551-RXL or U4551-RXL 200A, OH/UG, lever bypass, 7 terminal, small hub opening UTE7213BCH U9701-RL or U4701-RL 5 200A, OH/UG, lever bypass, 7 terminal, hub cover plate UTE7213CCH U9701-XL or U4701-XL 5 200A, OH/UG, lever bypass, 7 terminal, large hub opening UTE7213TCH U9701-R or U4701-R 200A, OH/UG, lever bypass, 7 terminal, large hub cover plate UTE7213UCH U9701-RX or U4701-RX 5 5 5 200A, OH/UG, lever bypass, 7 terminal, large hub opening with adapter plate UTE7213ZCH U9701-RRL or U4701-RRL 200A, OH/UG, lever bypass, 7 terminal, large hub opening with adapter and cover plate UTH7213YCH U9701-RXL or U4701-RXL 5 320A, OH, lever bypass, 4 terminal, large hub opening UTH4300TCH U1079-R or U1797-R 320A, OH, lever bypass, 4 terminal, large hub cover plate UTH4300UCH U1079-X or U1797X 5 320A, OH/UG, lever bypass, 4 terminal, large hub opening UTH4330TCH U2448-R or U2124-R 5 320A, OH/UG, lever bypass, 4 terminal, large hub cover plate UTH4330UCH U2448-RX or U2124-RX 320A, OH, lever bypass, 7 terminal, large hub opening UTH7300TCH — 5 320A, OH, lever bypass, 7 terminal, large hub cover plate UTH7300UCH — 320A, OH/UG, lever bypass, 7 terminal, large hub opening UTH7330TCH U2120-R 320A, OH/UG, lever bypass, 7 terminal, large hub cover plate UTH7330UCH U2120-X 5 5 5 5 5 5 V1-T5-32 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Accessories and Cross-Reference 5.6 Accessories 5 Manufacturer Eaton Milbank Description Part Number Part Number Small hub cover plate ARP00002CHB A7551 1-inch hub ARP00003CH1 A7514 1-1/4-inch hub ARP00004CH12 A7515 1-1/2-inch hub ARP00005CH15 A7516 2-inch hub ARP00006CH2 A7517 2-1/2-inch hub ARP00007CH25 A7518 3-inch hub ARP00019CH3 A8110 3-1/2-inch hub ARP00020CH35 A8111 4-inch hub ARP00021CH4 A8112 Large to small hub opening adapter plate ARP00015CHAP S8324 Large hub cover plate ARP00016CHB S9064 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-33 5.7 5 Metering Products Mechanical Lugs Contents Mechanical Lugs Description 5 Mechanical Lugs 5 5 5 5 5 5 5 5 5 5 5 5 5 Product Description ● ● ● Single lug Extended tang single lug Extended tang triple lug ● ● ● Double lug Extended tang double lug Extended tang quadruple lug Product Selection Dimensions Approximate Dimensions in Inches (mm) 5 Mechanical Lugs 5 Description Style Number Style Number Height Single #14–#6 mechanical lug ESL146 ESL146 2.50 (63.5) 8.25 (82.6) 3.50 (88.9) Single #14–2/0 mechanical lug ESL1420 ESL1420 2.50 (63.5) 10.50 (266.7) 3.50 (88.9) Single #6–250 kcmil mechanical lug ESL6250 ESL6250 2.50 (63.5) 10.50 (266.7) 3.50 (88.9) 5 Single #4–500 kcmil mechanical lug ESL4500 ESL4500 2.50 (63.5) 10.50 (266.7) 3.50 (88.9) 5 Double #14–2/0 mechanical lug EDL1420 EDL1420 3.50 (88.9) 4.00 (101.6) 3.50 (88.9) Double #6–250 kcmil mechanical lug EDL6250 EDL6250 3.50 (88.9) 3.75 (95.3) 4.50 (114.3) 5 Extended tang single lug #6–350 kcmil EPBSL6350 EPBSL6350 2.50 (63.5) 8.25 (82.6) 3.50 (88.9) Extended tang single lug 300–800 kcmil EPBSL300800 EPBSL300800 2.50 (63.5) 10.50 (266.7) 3.50 (88.9) 5 Extended tang double lug #6–350 kcmil EPBDL6350 EPBDL6350 3.50 (88.9) 4.50 (114.3) 5.50 (139.7) 5 Extended tang double lug 300–800 kcmil EPBDL300800 EPBDL300800 3.00 (76.2) 10.50 (266.7) 5.50 (139.7) Extended tang triple lug #6–350 kcmil EPBTL6350 EPBTL6350 3.50 (88.9) 4.50 (114.3) 5.50 (139.7) 5 Extended tang triple lug 300–800 kcmil EPBTL300800 EPBTL300800 2.50 (63.5) 10.00 (254.0) 5.75 (146.0) Extended tang quadruple lug #6–350 kcmil EPBQL6350 EPBQL6350 2.25 (57.2) 6.50 (165.1) 6.00 (152.4) 5 Extended tang quadruple lug 300–750 kcmil EPBQL300800 EPBQL300800 4.25 (108.0) 8.50 (215.9) 8.50 (215.9) Extended tang single lug #2–600 kcmil EPBSL2600 EPBSL2600 2.50 (63.5) 8.25 (82.6) 3.50 (88.9) Extended tang single lug 500–1000 kcmil EPBSL5001000 EPBSL5001000 2.50 (63.5) 10.50 (266.7) 3.50 (88.9) Extended tang triple lug #2–600 kcmil EPBTL2600 EPBTL2600 2.25 (57.2) 6.50 (165.1) 6.00 (152.4) 5 5 5 Mechanical Lugs 5 5 5 V1-T5-34 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Width Length Metering Products Communications Grounding Device (NEC 250.94) 5.8 Contents Communication Grounding Device Description Page Wiring Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . V1-T5-36 V1-T5-36 5 5 5 5 5 5 5 5 5 5 Product Description This product is required per the 2008 NEC Article 250.94 “Bonding for Other Systems.” This product is applied externally to residential homes, so that communications systems devices such as satellite, TV, cable and CATV can be properly bonded at a single point. This device has two mounting holes that can be used for easy installation. Features, Benefits and Functions Product Selection Communication Grounding Device Features ● Lay-in lug for ease of installation ● Four bonding terminals ● Heavy-duty zinc-plated steel screws included ● Two mounting holes to securely hold device into place ● For use with copper and aluminum conductors Communication Grounding Device 5 5 5 Wire Range Bonding Conductor Ground Electrode Quantity Catalog Number 5 #14–#2–STR–SOL–CU #12–#2–SRT–SOL–AL #8–1/0–STR–SOL–CU/AL (1) Clamshell MSEGR2CS 5 #14–#2–STR–SOL–CU #12–#2–SRT–SOL–AL #8–1/0–STR–SOL–CU/AL (10) Bulk pack MSEGR2 5 5 5 Cover Features ● Outdoor rated reinforced glass polyester compound ● Suitable for UV exposure ● Paintable exterior, allowing for matching of exterior of home 5 Standards and Certifications 5 ● 5 5 5 5 ETL listed 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-35 5.8 5 5 Metering Products Communications Grounding Device (NEC 250.94) Wiring Diagram Installation and Configuration 5 5 Service Entrance Panel 5 Single Meter Socket 5 5 5 5 Communication Grounding Device (Top View) 5 5 Grounding Electrode Conductor 5 5 5 5 5 5 5 5 Phone System Ground Grounding Electrode Conductor Communication Grounding Device (Top view) 5 Mounting Holes (Typical) 5 5 Satellite TV Ground 5 5 5 5 5 5 5 Coax Cable Ground Dimensions Approximate Dimensions in Inches (mm) Communication Grounding Device Catalog Number Length Width Height MSEGR2CS 0.75 (19.1) 3.90 (99.1) 1.20 (30.5) MSEGR2 0.75 (19.1) 3.90 (99.1) 1.20 (30.5) 5 V1-T5-36 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Meter Breakers 5.9 Contents Residential Meter Breakers Description Page Residential Meter Breakers Non-EUSERC Combination Service Entrance Devices 100–200A Styles . . . . . . . . . . . . . . . . . . Meets EUSERC Requirements Service Entrance Devices 100–225A . . . . . . . . . . . . . . . . . . . . . . . West Coast All-In-One Design. . . . . . . . . . . . . . . . Mechanical Interlock Cover . . . . . . . . . . . . . . . . . . House Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . Commercial Safety Sockets. . . . . . . . . . . . . . . . . . CH Style Renovation Solutions . . . . . . . . . . . . . . . Aluminum Meter Breakers . . . . . . . . . . . . . . . . . . V1-T5-39 V1-T5-48 V1-T5-59 V1-T5-65 V1-T5-75 V1-T5-83 V1-T5-86 V1-T5-87 5 5 5 5 5 5 5 5 5 5 5 Residential Meter Breakers Product Description Application Description A meter breaker is service entrance equipment that consists of a single meter socket and loadcenter (circuit breaker distribution section) or meter socket and main breaker combined in one enclosure. Sometimes called Combos, All-in-Ones, Meter Centers or Meter Mains, these units are increasing in popularity as the socket and loadcenter or main breaker are located in one location, thus providing the contractor with a labor and material savings when installing. In addition to residential installations, meter breakers are equally applicable for rural service entrance, mobile homes and construction site temporary power. Meter breakers are most often sold in the western, southwestern and southeastern United States. The popularity of meter breakers is continuing to increase as more utilities deregulate and pass the responsibility of supplying watthour meter sockets on to the electrical contractor. EUSERC/West Coast (Page V1-T5-59) Application Considerations Eaton has the meter breaker to meet your application, offering: CH and BR Styles (Page V1-T5-76). ● ● ● ● Non-EUSERC EUSERC/West Coast House panels Commercial safety socket Non-EUSERC (Page V1-T5-39) Eaton’s line of non-EUSERC meter breakers are designed for customers served by utilities that are not members of EUSERC. Eaton’s line of EUSERC required devices adhere to the agreed upon standards. EUSERC utilities are predominately located in the western United States, but some eastern and midwestern utilities are also members. These units can also be used in many Non-EUSERC areas. House Panels (Page V1-T5-75) Meter breaker device rated at 300–400A. Applied in EUSERC and non-EUSERC areas. Commercial Safety Sockets (Page V1-T5-83) ● ● ● ● ● ● ● ● ● ● Applied in EUSERC and non-EUSERC service areas and used in commercial applications. 5 Features, Benefits and Functions ● ● ● Both Type BR and CH branch circuit breaker styles available Meets latest NEC wire bending space requirements Slotted sealing screws at hub with sealing provision provided Surface units are supplied with mounting tabs Semi-flush units are supplied with stucco flange Meter socket ring landing will accept locking security rings Overhead or underground service Fifth jaw can be installed in the 3 o’clock or 9 o’clock position Semi-flush with nail flange or surface mounting Meter mounting and underground pull sections are utility sealable Units are rated a minimum of 10 kAIC; some units are 22 kAIC Numerous units supplied with center keyhole for ease of mounting NEMA 3R rainproof construction 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-37 5.9 5 5 Meter Breakers Standards and Certifications ● ● 5 ● 5 ● 5 ● 5 Metering Products ● UL Specification 414 (socket) UL File Number E52977 AEIC-EEI-NEMA Standards (MSJ-7) Meet EUSERC utility requirements where noted Documented seismic qualified—UBC® and CBC Title 24 UL Specification 67 (panel) Technical Data and Specifications ● ● ● ● Ratings single-phase, three-wire, 120/240 Vac 100–225A main breaker and main lug types 10,000A rms symmetrical short-circuit rating Available kAIC ratings: 10k with BW breaker, 22k with CSR breaker and 35k with CSH breaker Consult TD.31F.01.T.E for dimensions, wiring diagrams and knockouts. 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 V1-T5-38 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Meter Breakers 5.9 Contents Residential Meter Breakers Description Page Residential Meter Breakers. . . . . . . . . . . . . . . . . . Non-EUSERC Combination Service Entrance Devices 100–200A Styles Meets EUSERC Requirements Service Entrance Devices 100–225A . . . . . . . . . . . . . . . . . . . . . . . West Coast All-In-One Design. . . . . . . . . . . . . . . . Mechanical Interlock Cover . . . . . . . . . . . . . . . . . . House Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . Commercial Safety Sockets . . . . . . . . . . . . . . . . . CH Style Renovation Solutions . . . . . . . . . . . . . . . Aluminum Meter Breakers . . . . . . . . . . . . . . . . . . V1-T5-37 5 5 5 V1-T5-48 V1-T5-59 V1-T5-65 V1-T5-75 V1-T5-83 V1-T5-86 V1-T5-87 5 5 5 5 5 Standard Design Non-EUSERC Panel 5 Compact Design 5 5 Non-EUSERC Combination Service Entrance Devices 100–200A Styles Product Description Application Description A device that may include a meter socket, main breaker and loadcenter section within the same enclosure. Eaton’s line of non-EUSERC meter breakers are designed for customers served by utilities that are not members of EUSERC. ● ● Meter main = meter socket and main breaker Meter breaker = meter socket, main breaker and loadcenter section 5 Features, Benefits and Functions Meter Mains and All-in-Ones ● Single-phase, three-wire, 120/240 Vac,10 kAIC ● Larger lay-in lugs and 3-inch (76.2 mm) knockouts for ease of installation ● Box-type main lugs included ● Factory-installed neutral ● Hub provisions on top endwall. If hubs are required, order “DS” style ● Ring, ringless and ringless with horn bypass styles available ● Ringless style, provided with embossed covers and security latch for utility company lock ● Padlockable device covers provide additional measure of safety and help prevent tampering ● NEMA 3R rainproof construction Meter Mains ● Meter socket and main breaker ● Stainless steel latches on meter compartments in MBP types ● No distribution section included All-in-Ones ● Meter socket and loadcenter distribution section ● Stainless steel latches on meter compartments ● Several designs with horn bypass and fifth jaw ● Center-fed main breaker, lugs or provision ● Uses Type BR 1-inch (25.4 mm) wide branch breakers ● Special channel for top exit 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-39 5.9 5 Metering Products Meter Breakers Catalog Number Selection MB 20 40 B 200 BT S 5 5 MB MBE CMB CMBE 5 5 Meter Breaker Type = 1-inch BR Type = 1-inch BR Type—EUSERC = 3/4-Inch (19.1 mm) CH Type = 3/4-inch (19.1 mm) CH Type— EUSERC Spacing Number of spaces Poles Maximum number of poles Main B = Main breaker included P = Provision for main L = Main lug 5 5 Amperes Amperage of unit 5 D CU C CR Accessories/Modifications = 5th jaw and horn bypass = Copper = Single cover compact design = Two cover compact design Mounting S = Surface F = Flush/stucco Breaker Feed BT = Bottom and top B = Bottom only T = Top only 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 V1-T5-40 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Meter Breakers 5.9 Product Selection 5 Note: See knockout drawings on Pages V1-T5-68 through V1-T5-74 for hub information. Standard Design Non-EUSERC Panel 5 Combination Service Entrance Devices—Non-EUSERC Ampere Rating Bypass Service kAIC Jaws Distribution Main Branch Breaker Type Page Numbers Dimensions Catalog and Enclosure Wiring Knockout 1 Number Shape 1 5 5 5 Ring Style Meter Mains (no distribution section included) Compact Design 150 None OH/UG 10 4 None CSH2150 None 13 V1-T5-46 V1-T5-74 MBB150BTSCR 150 None OH/UG 22 4 None CSH2150 None 3 V1-T5-43 V1-T5-70 CMBB150BTS 67 200 None OH/UG 10 4 None CSH2200 None 13 V1-T5-46 V1-T5-74 MBB200BTSCR 200 None OH/UG 2 4 None Provision 45 None 3 V1-T5-43 V1-T5-70 CMBP200BTS 67 200 None OH/UG 22 4 None CSH2200 None 3 — V1-T5-70 CMBB200BTS 67 CSH2150 None 13 V1-T5-46 V1-T5-74 MBB150BTSC 7 Ringless Meter Mains (no distribution section included) 150 None OH/UG 10 4 None 8 200 None OH/UG 10 4 None CSH2200 None 9 V1-T5-47 V1-T5-74 MBB200BTS 200 None OH/UG 10 4 None CSH2200 None 13 V1-T5-46 V1-T5-74 MBB200BTSC 7 150 None OH/UG 10 4 None CSH2125 None 9 V1-T5-47 V1-T5-74 MBB150BTS 200 None OH/UG 2 4 None Provision 3 None 9 V1-T5-47 V1-T5-74 MBP200BTS 7 200 Horn OH/UG 2 5 None Provision 34 None 11 V1-T5-45 V1-T5-74 MBP200SD 200 Horn OH/UG 2 5 None Provision 34 None 9 V1-T5-47 V1-T5-74 MBP200BTSD 100 Horn OH/UG 10 5 None Provision None 15 — V1-T5-74 CHMMB100BTS 150 Horn OH/UG 10 5 None CSR2150 None 16 — V1-T5-74 CHMMB150BTS 200 Horn OH/UG 10 5 None CSR2200 None 16 — V1-T5-74 CHMMB200BTS 150 None OH/UG 10 4 4/8 CSR BR — — — MB48B150TSG 200 None OH/UG 10 4 4/8 CSR BR — — — MB48B200BTSG 200 Lever OH/UG 22 4 8/16 CSR BR — — — MBX816B200BTS 200 Lever OH/UG 22 4 20/40 CSR BR — — — MBX2040B200BTS Notes 1 See Page V1-T5-68 for box details. 2 Per installed main breaker rating. 3 When a provision for main is provided, order one of the main breakers listed in Page V1-T5-43. Panels are dual labeled to accept Types BW, CSR or CSH Main Breakers. 4 MCBK225 lug kit is needed for load side cable connection for Meter Mains. Please order separately. 5 When a provision for main is provided, order one of the main breakers listed in this table. Panels are labeled to accept Type CSR Main Breakers. 6 Copper bus. 7 One-piece cover on utility side, Florida approved. 8 Single cover design. 9 Xcel approved. 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-41 5.9 5 5 5 5 Metering Products Meter Breakers Note: See knockout drawings on Pages V1-T5-68 through V1-T5-74 for hub information. Combination Service Entrance Devices—Non-EUSERC, continued Ampere Rating Bypass Service kAIC Jaws Distribution Main Branch Breaker Type Dimensions and Enclosure Shape 1 Page Numbers Wiring Knockout 1 Catalog Number CH 2 V1-T5-43 V1-T5-70 CMB24L125BTS 56 CH 3 V1-T5-44 V1-T5-70 CMB88B150BTS 56 Ring Style All-in-Ones (includes distribution section) 125 None OH/UG 2 4 2/4 150 None OH/UG 22 4 8 200 None OH/UG 10 4 4/8 CSR2200 BR 3 V1-T5-44 V1-T5-70 MB48B200BTS 67 5 200 None OH/UG 22 4 8 CSH2200 CH 3 V1-T5-44 V1-T5-70 CMB88B200BTS 567 200 None UG 22 4 32/42 CSH2200 CH 7 V1-T5-43 V1-T5-69 CMB3242B200BS 56 5 200 None OH/UG 22 — 42/42 — CH — — — CMB4242B200BTS 5 5 5 5 None—refer to Distribution CSH2150 Ringless All-in-Ones (includes distribution section) 125 None OH/UG 22 4 4/8 CSR2125 BR 21 — V1-T5-73 MBT48B125BTS 150 None OH/UG 22 4 4/8 CSR2150 BR 21 V1-T5-46 V1-T5-73 MBT48B150BTS 150 Horn OH/UG 10 5 8/16 BW2150 BR 11 — — MB816B150STD 8 5 150 Horn OH/UG 10 5 20/40 BW2150 BR 11 V1-T5-47 V1-T5-74 MB2040B150SD 8 200 None OH/UG 10 4 8/16 CSR2200 BR 10 V1-T5-46 V1-T5-74 MB816B200BTS 67 5 200 None OH/UG 10 4 8/16 CSR2200 BR 10 V1-T5-46 V1-T5-74 MB816B200BTSCU 567 200 Horn OH/UG 10 5 8/16 BW2200 BR 11 — — MB816B200STD 8 5 200 None OH/UG 2 4 8/16 Provision 4 BR 10 V1-T5-46 V1-T5-74 MB816P200BTS 67 None OH/UG 2 5 200 4 8/16 Provision 4 BR 10 V1-T5-46 V1-T5-74 MB816P200BTSCU 567 200 Horn OH/UG 2 5 8/16 Provision 4 BR 11 V1-T5-46 V1-T5-74 MB816P200STD 78 200 Horn OH/UG 2 5 8/16 Provision 4 BR 10 V1-T5-46 V1-T5-74 MB816P200BTSD 7 200 None OH/UG 10 4 12/12 CSH2200 CH 10 V1-T5-44 V1-T5-70 CMB1212B200BTS 567 OH/UG 2 4 6–2 Pole Main lugs CH 9 V1-T5-45 V1-T5-71 CMB1212L200BTS 57 OH/UG 2 4 12/12 Provision CH 10 V1-T5-45 V1-T5-71 CMB1212P200BTS 567 4 6–2 Pole Main lugs BR 9 V1-T5-44 V1-T5-71 MB1212L200BTS 7 CMB2424B200BTS 56 5 5 5 200 200 None None 4 5 200 None OH/UG 2 5 200 None OH/UG 22 4 24/24 CSH2200 CH 10 V1-T5-44 V1-T5-74 200 None OH/UG 22 4 24/36 CSH2200 CH 10 V1-T5-45 V1-T5-74 CMB2436B200BTS 5 5 200 None OH/UG 10 4 20/40 CSR2200 BR 10 V1-T5-47 V1-T5-74 MB2040B200BTS 6 200 None OH/UG 2 4 20/40 Provision 4 BR 10 V1-T5-47 V1-T5-74 MB2040P200BTS 6 5 20/40 Provision 4 BR 11 V1-T5-47 V1-T5-74 MB2040P200SD 8 5 200 Horn OH/UG 2 5 200 Horn OH/UG 10 5 20/40 CSR2200 BR 10 V1-T5-47 V1-T5-74 MB2040B200SD 8 200 Lever OH/UG 10 5 None CSH2200 None 14 V1-T5-45 V1-T5-73 CMBXB200BTS 5 5 200 Lever OH/UG 10 5 12/12 CSH2200 CH 14 V1-T5-45 V1-T5-73 CMBX1212B200BTS 57 200 Lever OH/UG 10 5 32/42 CSH2200 CH 14 V1-T5-46 V1-T5-73 CMBX3242B200BTS 5 5 200 Lever OH/UG 10 5 None Provision None 14 V1-T5-45 V1-T5-73 CMBXP200BTS 5 200 Lever OH/UG 10 5 12/12 Provision CH 14 V1-T5-45 V1-T5-73 CMBX1212P200BTS 57 5 200 Lever OH/UG 10 5 32/42 Provision CH 14 V1-T5-46 V1-T5-73 CMBX3242P200BTS 5 5 200 None OH/UG 2 4 4/8 Provision BR 21 V1-T5-46 V1-T5-73 MBT48P200BTS 7 200 None OH/UG 22 4 4/8 CSR2200 BR 21 V1-T5-46 V1-T5-73 MBT48B200BTS 7 5 5 5 5 Notes 1 See Page V1-T5-68 for box details. 2 Per installed main breaker rating. 3 Will accept maximum four single-pole, two-pole, or two quad breakers. 4 When a provision for main is provided, order one of the main breakers listed on Page V1-T5-43. All panels are dual labeled to accept Types BW, CSR, CSH Main Breakers. 5 Copper bus. 6 One-piece cover on utility side, Florida approved. 7 Units come with feed-through lugs. 8 Xcel approved. 5 V1-T5-42 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Meter Breakers 5.9 Main Breaker Selection Chart 5 Maximum Ampere Rating Two-Pole Breaker Catalog Numbers 10 kAIC 25 kAIC 25 kAIC 35 kAIC 100 BW2100 CSR2100 CSR2100N CSH2100N 125 BW2125 CSR2125 CSR2125N CSH2125N 150 BW2150 CSR2150 CSR2150N CSH2150N 200 BW2200 CSR2200 CSR2200N CSH2200N Load Side Lug Kit for BW and CSR Breakers 1 MCBK225 5 5 5 5 5 Wiring Diagrams Catalog Number—CMB3242B200BS 47a. Bonded Neutral 1 2 3 4 5 6 7 8 9 10 11 12 13 23 24 25 26 27 28 29 30 31 32 14 34 15 35 16 36 17 37 18 38 19 39 20 40 21 41 22 42 Catalog Numbers—CMBP200BTS, CMBB150BTS 47c. 5 Install 200 Ampere Maximum Service Disconnect Type CSR 2 5 A 5 B 5 33 5 Bonded Neutral 5 A B Line N 5 Bonded Neutral 5 5 Wiring Diagram Key #14-2/0 AWG #14-2 AWG #6-250 AWG Service Disconnect Type CSR A N B Line Wiring Diagram Key #14-2 AWG #14-4 AWG #6-2/0 AWG #6-250 AWG 5 5 Catalog Number—CMB24L125BTS 47d. 5 B A 5 5 5 12 34 A Line N B 5 Bonded Neutral 5 5 5 Wiring Diagram Key #14-1/0 AWG #14-6 AWG #14-1/0 AWG #6-250 AWG 5 5 Notes 1 When a provision for main is provided, order one of the main breakers listed in this table. All panels are dual labeled to accept Types BW, CSR and CSR Main Breakers. 2 Factory-installed MCBK225 Kit for C/B load lugs. 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-43 5.9 5 Meter Breakers Catalog Numbers—CMB88B200BTS, CMB88B150BTS 48a. Catalog Number—MB1212L200BTS 48e. Service Disconnect Type CSR 200 Ampere Maximum Bonded Neutral 5 A 5 1 2 3 4 5 6 7 8 5 5 B A Line N 5 5 5 5 5 A B Ground Bar 1 2 3 4 5 6 7 8 9 10 11 12 Wiring Diagram Key Wiring Diagram Key #14-1/0 AWG #14-6 AWG #6-2/0 AWG #6-250 AWG #4-300 AWG #14-2/0 AWG #6-350 kcmil #6-300 kcmil Catalog Number—MB48B200BTS 48c. Catalog Number—CMB2424B200BTS 48f. A 200A Maximum Service Disconnect Type BW or CSR 5 5 N B Bonded Neutral 5 Group Metering and Meter Breakers A Line N B Bonded Neutral B 5 200 Ampere Maximum Service Disconnect Type CSR 1 2 3 4 5 6 7 8 5 5 A 5 Line N B L1 5 L2 Bonded Neutral Wiring Diagram Key #14-1/0 AWG #14-6 AWG #6-2/0 AWG #6-250 AWG 5 5 5 Catalog Number—CMB1212B200BTS 48d. 5 5th Jaw Factory Installed on CMB1212B200BTSD and CMB1212P200BTSD Only 5 A B Bonded Neutral 5 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Wiring Diagram Key #14-4 AWG #6-350 kcmil #6-2/0 AWG #4-300 kcmil Line N 5 5 200 Ampere Maximum Service Disconnect Type CSR or CSH 5 5 5 1 2 3 4 5 6 7 8 9 10 11 12 5 V1-T5-44 Wiring Diagram Key #14-4 AWG #6-350 kcmil #6-2/0 AWG #4-300 kcmil #6-300 kcmil Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Group Metering and Meter Breakers Meter Breakers Catalog Number—CMB1212L200BTS 49a. Catalog Numbers—MBP200SD, CMBXB200BTS, CMBXP200BTS 49c. 5th Jaw Factory Installed on CMB1212L200BTSD Only B 5 5 CMBXB200BTS & CMBXP200BTS B included lever by pass meter socket A A 5.9 N 5 Line N Bonded Neutral 5 5 5 1 2 3 4 5 6 7 8 9 10 11 12 5 CMBXB200BTS factory installed 200A Max Service Disconnect type CSR Wiring Diagram Key #14-4 AWG #6-350 kcmil #6-2/0 AWG #6-300 kcmil 5 5 MBP200SD install 200A Max Service Disconnect Type BW or CSR 5 5 Wiring Diagram Key #6-2/0 AWG #6-350 kcmil #1-300 kcmil #6-300 kcmil Catalog Number—CMB2436B200BTS 49b. A B Line N 5 5 Catalog Numbers—CMB1212B150BTS, CMBX1212B200BTS, CMB1212B200BTS, CMB1212P200BTS, CMBX1212P200BTS 49d. 5th Jaw Factory Installed on CMB1212B200BTSD and CMB1212P200BTSD Only Bonded Neutral A B Bonded Neutral 5 5 5 5 Line N 5 5 200A Max. Service Disconnect Type CSR or CSH 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 Wiring Diagram Key #14-4 AWG #6-350 kcmil #6-2/0 AWG Maximum of 12 twin #4-300 kcmil Breakers as Shown 5 200 Ampere Maximum Service Disconnect Type CSR or CSH 1 2 3 4 5 6 7 8 9 10 11 12 5 Wiring Diagram Key #14-4 AWG #6-350 kcmil #6-2/0 AWG #4-300 kcmil #6-300 kcmil 5 5 5 CMBX1212B200BTS & CMBX1212P200BTS include lever bypass meter socket 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-45 5.9 5 Group Metering and Meter Breakers Meter Breakers Catalog Numbers—MBT48B200BTS, MBT48P200BTS, MBT48B150BTS, MBT48P150BTS 50a. 5 A Catalog Numbers—MBB150BTSC, MBB150BTSCR, MBB200BTSCR and MBB200BTSC 50c. A B B Line N 5 5 5 Included in MBB150BTSCR 5 Factory or Field installed. 15A or 200A Max. Service Disconnect 5 5 5 5 5 5 5 Catalog Numbers—CMBX3242P200BTS, CMBX3242B200BTS 50b. 5 A 5 Wiring Diagram Key #6-2/0 AWG #6-350 kcmil #6-250 kcmil #1-300 kcmil Catalog Numbers—MB816P200STD, MB816B200BTS, MB816B200BTSCU, MB816P200BTS, MB816P200BTSCU and MB816P200BTSD 50d. A B Line N Bonded/ Neutral 5 5 CMBX3242P200BTS 200 A Max. Service Disconnect Type CSR or CSH (not included) 5 CMBX3242B200BTS 200 A Max. Service Disconnect Factory Installed Type CSR or CSH 5 5 1 2 3 4 5 5 6 7 8 9 10 5 11 13 12 14 15 17 16 18 20 5 5 Bonded Neutral Includes Lever Bypass Meter Socket Line N B 5 5 Line N Wiring Diagram Key #6-2/0 AWG #6-350 kcmil #1-300 kcmil #6-300 kcmil 12 34 56 78 19 25 29 33 37 21 23 27 31 35 39 200A Maximum Service Disconnect Type CSR Bonded Neutral 1 3 5 7 9 11 13 15 2 4 6 8 10 12 14 16 200A Maximum Service Disconnect Type BW or CSR Wiring Diagram Key #14-4 AWG #6-350 kcmil #6-2/0 AWG #6-300 kcmil #6-300 kcmil Maximum of 10 Twin Breakers as shown 22 24 26 28 30 32 34 36 38 40 41 42 Wiring Diagram Key #14-4 AWG #6-350 kcmil #6-2/0 AWG #6-300 kcmil 5 5 5 5 V1-T5-46 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Group Metering and Meter Breakers Meter Breakers 5.9 Catalog Numbers—MBB150BTS, MBP200SD, MBB200BTS, MBP200BTS, MBP200BTSD, CMBXB200BTS and CMBXP200BTS 51a. A 5 5 B 5 Line N 5 5 Bonded Neutral 5 200A Maximum Service Disconnect Type BW or CSR 1 5 5 5 Wiring Diagram Key #6-2/0 AWG #6-350 kcmil #1-300 kcmil #6-300 kcmil 5 5 5 Catalog Numbers—MB2040P200SD, MB2040B200BTS, MB2040P200BTS, MB2040B150SD and MB2040B200SD 51b. A 5 B 5 Line N 5 Bonded Neutral 5 200A Maximum Service Disconnect Type BW or CSR 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 5 5 5 5 Wiring Diagram Key #14-4 AWG #6-350 kcmil #6-2/0 AWG 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-47 5.9 5 Metering Products Meter Breakers Contents Residential Meter Breakers Description 5 Residential Meter Breakers . . . . . . . . . . . . . . . . . Non-EUSERC Combination Service Entrance Devices 100–200A Styles. . . . . . . . . . . . . . . . . . Meets EUSERC Requirements Service Entrance Devices 100–225A West Coast All-In-One Design . . . . . . . . . . . . . . . Mechanical Interlock Cover . . . . . . . . . . . . . . . . . . House Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . Commercial Safety Sockets . . . . . . . . . . . . . . . . . CH Style Renovation Solutions . . . . . . . . . . . . . . . Aluminum Meter Breakers . . . . . . . . . . . . . . . . . . 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Meets EUSERC Requirements Service Entrance Devices 100–225A Meets EUSERC Requirements Service Entrance Devices 100–225A Product Description Eaton is proud to introduce a new line of West Coast/ EUSERC Meter Breaker units. The new EUSERC devices complement the existing standard meter breaker devices. Customers who are interested in the complete meter breaker line of products can refer to Technical Data TD.31F.01.T.E. Features, Benefits and Functions ● ● ● ● ● Application Description Eaton’s line of EUSERC required devices adhere to the agreed upon standards. EUSERC utilities are predominately located in the western United States, but some eastern and midwestern utilities are also members. These units can also be used in many Non-EUSERC areas. ● ● ● ● 5 Single-phase, three-wire, 120/240V, 10 kAIC Larger 250 kcmil lugs and additional knockouts for ease of installation Box type main lugs are included Factory-installed neutrals Hub provisions on top endwall. If hubs are required, order “DS” type hubs Ring type sockets are provided with a sealing ring Padlockable device covers provide an additional measure of security and help prevent tampering Most units have center keyhole for easy oneperson installation NEMA 3R rainproof construction 5 5 5 5 5 5 V1-T5-48 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Page V1-T5-37 V1-T5-39 V1-T5-59 V1-T5-65 V1-T5-75 V1-T5-83 V1-T5-86 V1-T5-87 Metering Products Meter Breakers 5.9 Catalog Number Selection 5 MBE 20 40 B 200 B S Meter Breaker Type MB = 1-inch (25.4 mm) BR Type MBE = 1-inch (25.4 mm) BR Type—EUSERC CMB = 0.75-inch (19.1 mm) CH Type CMBE = 0.75-inch (19.1 mm) CH Type—EUSERC MBED = 7-inch (177.8 mm) deep MBER = 1-inch (25.4 mm) BR Type—EUSERC ranch CMBER = 0.75-inch (19.1 mm) CH Type—EUSERC ranch MBEB = 1-inch (25.4 mm) BR Type back-to-back MBX = Xcel approved lever bypass meter breaker Spacing Number of spaces Poles Maximum number of poles Main B = Main breaker included P = Provision for main L = Main lug Amperes Amperage of unit 5 D CU C CR 5 Accessories/Modifications = 5th jaw and horn bypass = Copper = Single cover compact design = Two cover compact design Mounting S = Surface F = Flush/stucco Breaker Feed BT = Bottom and top B = Bottom only T = Top only 5 5 Last Digits G = Suffix = GA PWE spec R 1 = Suffix = ECCN renovation PV = Suffix = PV rated units 6 = 2 x 6 construction A = Aluminum enclosure 5 5 5 5 Note 1 Not available in CR. 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-49 5.9 5 5 5 5 5 5 5 Metering Products Meter Breakers Product Selection Note: See knockout drawings on Pages V1-T5-68 through V1-T5-74 for hub information. Combination Service Entrance Devices—EUSERC Ampere Rating By-pass Service kAIC Jaws Distribution Dimensions and Enclosure Shape 1 Page Numbers Main Branch Breaker Type Wiring Knockout 1 Catalog Number—Surface Catalog Number—Flush Ring Style Meter Mains (no distribution section included) 125 None OH/UG 2 4 2/4 MLO BR 2 V1-T5-55 V1-T5-70 MBE24L125BTS MBE24L125BTF 125 None OH/UG 2 4 2/4 MLO CH 2 V1-T5-53 V1-T5-70 CMBE24L125BTS 3 — 150 None OH/UG 22 4 None CSH2150N None 3 V1-T5-52 V1-T5-70 CMBEB150BTS 3 — 200 None OH/UG 10 4 None CSR2200 None 3 V1-T5-56 V1-T5-70 MBEB200BTS MBEB200BTF — 200 None OH/UG 22 4 None CSH2200N None 3 V1-T5-52 V1-T5-70 CMBEB200BTS 3 5 200 None OH/UG 2 4 2/4 MLO BR 3 V1-T5-56 V1-T5-70 MBE24L200BTS MBE24L200BTF 200 None OH/UG 2 4 2/4 MLO CH 3 V1-T5-53 V1-T5-70 CMBE24L200BTS 3 — 5 Ring Style All-in-Ones (includes distribution section) 100 None OH/UG 10 4 12/24 BR2100 BR 2 V1-T5-53 V1-T5-70 MBE1224B100BTS MBE1224B100BTF 5 100 None UG 10 4 14/28 BR2100 BR 4 V1-T5-55 V1-T5-69 MBE1428B100BS MBE1428B100BF 5 100 None OH 10 4 12/24 BR2100 BR 9 V1-T5-58 V1-T5-71 MBE1224B100TS — 125 None OH/UG 10 4 12/24 BR2125 BR 2 V1-T5-53 V1-T5-70 MBE1224B125BTS MBE1224B125BTF 5 125 None OH 10 4 12/24 BR2125 BR 9 V1-T5-58 V1-T5-71 MBE1224B125TS — 125 None UG 10 4 18/36 BR2125 BR 5 V1-T5-54 V1-T5-69 — MBE1836B125BF 150 None OH/UG 10 4 4/8 CSR2150 BR 19 — — MBER48B150BTS 48 — 150 None OH/UG 22 4 8/8 CSH2150N CH 19 — — CMBER88B150BTS 348 — 150 None OH/UG 22 4 8 CSH2150N CH 3 V1-T5-53 V1-T5-70 CMBE88B150BTS 34 CMBE88B150BTF 34 150 None UG 22 4 32/42 CSH2150N CH 7 V1-T5-52 V1-T5-69 CMBE3242B150BS 3 — 150 None UG 10 4 20/40 CSR2150 BR 6 V1-T5-54 V1-T5-69 — MBE2040B150BF 5 5 5 5 5 5 5 5 Notes 1 See Page V1-T5-68 for box details. 2 Interrupting rating is dependent on the main breaker that is installed. 3 Unit has copper bus. 4 Units come with feed-through lugs. 5 Please use RH-Type hubs on top end wall for overhead feed. 6 Includes factory-mounted 2.50-inch hub on bottom endwall. UG feed only. 7 Semi flush flange, not full stucco flange. 8 Units include a two-pole provision for secondary main 70A max. Type BR, BRH, BRHH. 5 5 5 5 5 5 5 5 5 5 5 V1-T5-50 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 5.9 Metering Products Meter Breakers Note: See knockout drawings on Pages V1-T5-68 through V1-T5-74 for hub information. 5 Combination Service Entrance Devices—EUSERC, continued 5 Ampere ByRating pass Service kAIC Jaws Distribution Main Dimensions and Enclosure Shape 1 Page Numbers Branch Breaker Type Wiring Knockout 1 Catalog Number—Surface Catalog Number—Flush 5 5 Ring Style All-in-Ones (includes distribution section), continued 150 None OH/UG 22 4 20/40 CSR2150 BR — V1-T5-55 — MBE2040B150BTS 6 — 150 None OH/UG 10 4 4/8 CSR2150 BR 3 V1-T5-56 V1-T5-70 MBE48B150BTS — 200 None OH/UG 10 4 4/8 CSR2200 BR 3 V1-T5-56 V1-T5-70 MBE48B200BTS 4 MBE48B200BTF 4 200 None OH/UG 22 4 8 CSH2200N CH 3 V1-T5-53 V1-T5-70 CMBE88B200BTS 34 CMBE88B200BTF 34 200 None OH/UG 10 4 8 CSR2200 BR 3 V1-T5-56 V1-T5-70 MBE88B200BTS — 200 None OH/UG 10 4 4/8 CSR2200 BR 19 V1-T5-58 V1-T5-73 MBER48B200BTS 48 — 200 None OH/UG 10 4 4/8 CSR2200 BR 19 V1-T5-58 V1-T5-73 MBER48B200BTS 48 — 4 8/16 Provision BR 10 V1-T5-57 V1-T5-71 MBE816P200TSCU 36 — 4 8/16 Provision BR 10 V1-T5-57 V1-T5-71 MBE816P200TS 46 — MBE1212L200BTF 200 None OH/UG 2 200 None OH 2 4 6–2 Pole Main Lug CH 5 V1-T5-52 V1-T5-69 CMBE1212L200BS 3 4 6–2 Pole Main Lug BR 9 V1-T5-57 V1-T5-69 MBE1212L200BTS — 5 5 5 5 5 200 None UG 2 200 None OH/UG 2 200 None OH 10 4 20/40 CSR2200 BR 10 V1-T5-57 V1-T5-71 MBE2040B200TS 6 MBE2040B200TF 5 200 None UG 10 4 20/40 CSR2200 BR 6 V1-T5-54 V1-T5-69 MBE2040B200BS 6 MBE2040B200BF 5 200 None OH/UG 22 4 20/40 CSR2200 BR — V1-T5-55 — MBE2040BH200BTS 6 — — MBE3042B200BF 200 None OH/UG 22 4 20/40 CSR2200 BR — V1-T5-55 — MBE2040BH200BTF 6 200 None UG 22 4 30/42 CSR2200 BR 7 V1-T5-54 — — CMBE3242B200BF 200 None UG 22 4 32/42 CSH2200N CH 7 V1-T5-52 V1-T5-69 200 None UG 22 4 40 CSR2200 BR 12 V1-T5-58 — MBE4040B200BSH 6 — 200 None OH/UG 22 4 40 CSR2200 BR 12 V1-T5-58 — MBE4040B200BTS MBE4040B200BTF 7 200 None OH/UG 22 4 42 CSH2200N CH 12 V1-T5-57 — CMBE4242B200BTS 3 — 200 None OH/UG 10 4 20/40 CSR2200 BR 18 V1-T5-55 V1-T5-73 MBE2040B200BTS 6 MBE2040B200BTF 6 225 None OH/UG 10 4 20/40 CSR2225 BR 18 V1-T5-58 V1-T5-73 MBE2040B225BTS 6 MBE2040B225BTF 6 225 None UG 22 4 30/42 CSR2225 BR 7 V1-T5-55 — — MBE3042B225BF V1-T5-69 CMBE3242B225BS 3 None UG 22 4 32/42 CSH2225N CH 7 V1-T5-52 CMBE3242B225BF 5 5 5 CMBE3242B200BS 3 225 5 3 3 Notes 1 See Page V1-T5-68 for box details. 2 Interrupting rating is dependent on the main breaker that is installed. 3 Unit has copper bus. 4 Units come with feed-through lugs. 5 When a provision for main is provided, order one of the main breakers listed on Page V1-T5-68. All panels are dual labeled to accept Types BW or CSR Main Breakers. 6 Please use RH-Type hubs on top end wall for overhead feed. 7 Includes factory-mounted 2.50-inch hub on bottom endwall. UG feed only. 8 Semi-flush flange, not full stucco flange. 9 Units include a two-pole provision for secondary main 70A max. Type BR, BRH, BRHH. 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-51 5.9 5 Meter Breakers Wiring Diagrams Catalog Numbers—CMBE3242B150BS, CMBE3242B200BS, CMBE3242B200BF, CMBE3242B225BS and CMBE3242B225BF 56a. 1 2 3 4 5 6 7 8 9 10 11 12 13 23 24 25 26 27 28 29 30 31 32 14 34 15 35 16 36 17 37 18 38 5 19 39 20 40 21 41 5 22 42 5 5 5 Bonded Neutral 5 33 Bonded Neutral N 5 5 A 5 Line 2 4 6 8 10 12 14 16 18 20 21 22 Bonded Neutral 1 3 5 7 9 11 13 15 17 19 5 5 Install 200 Ampere Maximum Service Disconnect Type CSR 2 A A 5 5 Catalog Numbers—CMBEB150BTS and CMBEB200BTS 56d. B Service Disconnect 5 5 Wiring Diagram Key #14-4 AWG #6-1/0 AWG #6-250 AWG Wiring Diagram Key #14-2 AWG #14-4 AWG #6-2/0 AWG #6-250 AWG Catalog Numbers—CMBE2222P125BF and CMBE2222P125BS Bonded Neutral 5 B N 5 5 Line Service Disconnect Type CSR 5 5 B A 5 5 2 4 6 8 10 12 1 3 5 7 9 11 Bonded Neutral 5 Catalog Number—CMBE1212L200BS 56c. Bonded Neutral 5 Group Metering and Meter Breakers B A N Line Wiring Diagram Key #14-4 AWG #6-2/0 AWG #14-2/0 AWG #6-250 AWG Line N B Bonded Neutral Wiring Diagram Key #14-2/0 AWG #14-2 AWG #6-250 AWG Note 1 Factory-installed MCBK225 kit for C/B load lugs. 5 5 5 5 5 V1-T5-52 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Group Metering and Meter Breakers Meter Breakers Catalog Number—CMBE24L125BTS 57a. 5.9 Catalog Numbers—CMBE88B200BTS, CMBE88B200BTF, CMBE88B150BTS and CMBE88B150BTF 57c. 5 Service Disconnect Type CSR 200 Ampere Maximum 5 B A A 5 B 5 12 34 Line N B Bonded Neutral 1 2 3 4 5 6 7 8 B A Line N Wiring Diagram Key #14-1/0 AWG #14-6 AWG #14-1/0 AWG #6-250 AWG 5 Bonded Neutral A 5 5 5 Wiring Diagram Key #14-1/0 AWG #14-6 AWG #6-2/0 AWG #6-250 AWG #4-300 AWG Catalog Number—CMBE24L200BTS 57b. 5 5 5 Catalog Numbers—MBE1224B100BTS, MBE1224B100BTF, MBE1224B125BTS and MBE1224B125BTF 57d. 5 B A 1 2 3 4 5 Main 12 34 A Line N B Bonded Neutral A Bonded Neutral Wiring Diagram Key #14-6 AWG #14-1/0 AWG #6-250 AWG B 5 5 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 5 5 5 5 Wiring Diagram Key #14-6 AWG #14-1/0 AWG #14-2/0 AWG #6-250 AWG 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-53 5.9 5 5 Bonded Neutral 5 Catalog Numbers—MBE1212L200BF and MBE1212L200BS 1 3 5 7 9 11 5 A N 5 Catalog Number—MBE1836B125BF 58b. Bonded Neutral 5 5 Line N Wiring Diagram Key #14-6 AWG #6-1/0 AWG #6-250 AWG Catalog Number—MBE3042B200BF 58d. 1 2 3 5 4 6 7 8 9 11 10 12 13 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 15 17 19 21 23 25 27 29 31 33 35 37 39 41 Service Disconnect Service Disconnect Type BW or CSR 5 5 5 5 Bonded Neutral 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 33 34 35 36 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 Bonded Neutral 5 B Line Wiring Diagram Key #14-4 AWG #6-2/0 AWG #6-250 AWG Bonded Neutral 5 5 B A 5 5 2 4 6 8 10 12 Service Disconnect Type BW or CSR 5 5 Bonded Neutral 5 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 Bonded Neutral 5 Meter Breakers Catalog Numbers—MBE2040B150BF, MBE2040B200BS and MBE2040B200BF 58a. Bonded Neutral 5 Group Metering and Meter Breakers A N B Line Wiring Diagram Key #14-4 AWG #6-2/0 AWG #14-2/0 AWG #6-250 AWG N A LINE B Wiring Diagram Key #14-4 AWG #6-2/0 AWG #6-250 AWG 5 5 5 5 5 5 5 5 5 V1-T5-54 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Group Metering and Meter Breakers Meter Breakers Catalog Numbers—MBE1428B100BS and MBE1428B100BF 59a. Bonded Neutral Bonded Neutral Service Disconnect A B Line N Catalog Number—MBE3042B225BF 59c. 1 2 3 5 4 6 7 8 9 11 13 10 12 5 5 5 5 5 Service Disconnect Type BW or CSR Wiring Diagram Key #14-4 AWG #6-2/0 AWG #14-2/0 AWG #6-250 AWG N A Catalog Numbers—MBE2040B200BTS, MBE2040B150BTS, MBE2040BH200BTS and MBE2040BH200BTF 59b. LINE B 5 Wiring Diagram Key #14-4 AWG #6-2/0 AWG #6-250 AWG 5 5 Catalog Numbers—MBE24L125BTS and MBE24L125BTF 59d. A B 200A Max. Service Disconnect B A 5 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 15 17 19 21 23 25 27 29 31 33 35 37 39 41 5 Bonded Neutral Bonded Neutral 2 4 6 8 10 12 14 16 18 20 22 24 25 26 27 28 1 3 5 7 9 11 13 15 17 19 21 23 5.9 5 5 5 5 5 1 2 34 56 B A N Bonded Neutral Wiring Diagram Key #14-6 AWG #14-1/0 AWG #6-250 AWG 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 A Line N B Bonded Neutral 5 5 5 5 Wiring Diagram Key #14-1/0 AWG #14-6 AWG #14-2/0 AWG #6-250 AWG 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-55 5.9 5 Group Metering and Meter Breakers Meter Breakers Catalog Numbers—MBE48B150BTS, MBE48B200BTS, MBE48B200BTF 60a. 5 5 5 200A Maximum Service Disconnect Type BW or CSR A A B B 1 2 34 56 5 1 2 3 4 5 6 7 8 5 5 Catalog Numbers—MBE24L200BTS and MBE24L200BTF 60c. A Line N B L1 A Line N B Bonded Neutral L2 Bonded Neutral 5 5 5 5 Catalog Numbers—MBEB200BTS and MBEB200BTF 60b. Catalog Number—MBE88B200BTS 60d. 200A Maximum Service Disconnect Type BW or CSR 200A Maximum Service Disconnect Type BW or CSR 5 5 Wiring Diagram Key #14-1/0 AWG #14-6 AWG #14-2/0 AWG #6-250 AWG Wiring Diagram Key #14-1/0 AWG #14-6 AWG #6-2/0 AWG #6-250 AWG A A B B 5 5 5 5 MCBK225 Kit for C/B Load Lugs A Line N B Bonded Neutral 5 5 Wiring Diagram Key #14-2/0 AWG #6-2/0 AWG #6-250 AWG 5 A Line N B 1 2 3 4 5 6 7 8 Wiring Diagram Key #14-1/0 AWG #14-6 AWG #6-2/0 AWG #6-250 AWG 5 5 5 5 5 5 5 5 5 V1-T5-56 Bonded Neutral 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Group Metering and Meter Breakers Meter Breakers Catalog Numbers—MBE816P200TS and MBE816P200TSCU 61a. A 5.9 Catalog Number—MBE1212L200BTS 61d. B A 5 B 5 Line N 5 Bonded Neutral 1 3 5 7 9 11 13 15 2 4 6 8 10 12 14 16 N 200A Maximum Service Disconnect Type BW or CSR 1 2 3 4 5 5 5 6 7 8 9 10 11 12 Wiring Diagram Key #14-4 AWG #6-350 kcmil #6-2/0 AWG #6-300 kcmil #6-300 kcmil 5 5 Wiring Diagram Key #14-4 AWG #6-350 kcmil #6-2/0 AWG #6-300 kcmil Catalog Numbers— MBE2040B200TS and MBE2040B200TF 61b. A 5 Bonded Neutral 5 5 5 Catalog Number—CMBE1212L200TS 61e. B A 5 N B Bonded Neutral Line N 5 5 Bonded Neutral 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 5 200A Maximum Service Disconnect Type BW or CSR 2 3 4 5 5 5 6 7 8 9 10 11 12 5 Wiring Diagram Key #14-4 AWG #6-350 kcmil #6-2/0 AWG #6-300 kcmil Wiring Diagram Key #14-4 AWG #6-350 kcmil #6-2/0 AWG 5 Catalog Number—CMBE4242B200BTS 61f. 5 B 1 A B 2 3 LINE N B 4 5 6 A Wiring Diagram Key #14-4 AWG #6-350 kcmil #6-2/0 AWG 5 Factory Installed Service Disconnect Type CSR Bonded Neutral A 5 5 Catalog Number—MBE1212L200BTS 61c. A 1 Bonded B Neutral Wiring N Diagram Key #14-6 AWG #14-1/0 AWG #6 AWG-250 kcmil 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 5 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 5 5 5 5 5 5 V1-T5-57 5.9 5 Group Metering and Meter Breakers Meter Breakers Catalog Numbers—CMBER88B200BTS and CMBER88B200BTF 62a. 5 Catalog Numbers—MBE2040B225BTS, MBE2040B225BTF 62d. 225A Max. Service Disconnect Service Disconnect Type CSR or CSH Max 200A 5 A B A B A B 5 1 2 3 4 5 6 7 8 5 5 A 5 Line N B Secondary Service Disconnect 70A Max Bonded Neutral Wire Range 5 #14-1/0 #5-2/0 AWG #14-6 AWG #5-250 AWG #4-300 AWG 5 N Bonded Neutral Wiring Diagram Key #14-6 AWG #14-1/0 AWG #6-250 AWG 5 5 5 Catalog Numbers—MBE4040B200BTS and MBE4040B200BSH 62b. 5 A 5 A B 5 5 Bonded B Neutral A 5 Line N 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 5 5 N Wiring Diagram Key #14-6 AWG #14-1/0 AWG #6 AWG-250 kcmil 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 5 5 B Factory Installed Service Disconnect Type BW 5 5 Catalog Numbers—MBE1224B125TS and MBE1224B100TS 62e. Bonded Neutral 125A Maximum Service Disconnect Type BR, or BRH 1 3 5 7 9 11 13 15 17 19 21 23 2 4 6 8 10 12 14 16 18 20 22 24 Equipment Ground Wiring Diagram Key #14-4 AWG #14-1/0 AWG #6-350 kcmil Catalog Numbers—MBER48B200BTS and MER48B200BTF 62c. Service Disconnect Type CSR or CSH Max 200A 5 A B 5 5 5 5 A Line N 1 2 3 4 5 6 7 8 B Secondary Service Disconnect 70A Max Bonded Neutral Wire Range 5 #14-1/0 #14-6 AWG 5 V1-T5-58 #5-2/0 AWG #5-250 AWG #4-300 AWG Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Meter Breakers 5.9 Contents West Coast All-In-One Design Description Residential Meter Breakers . . . . . . . . . . . . . . . . . . Non-EUSERC Combination Service Entrance Devices 100–200A Styles . . . . . . . . . . . . . . . . . . Meets EUSERC Requirements Service Entrance Devices 100–225A . . . . . . . . . . . . . . . . . . . . . . . West Coast All-In-One Design Mechanical Interlock Cover . . . . . . . . . . . . . . . . . . House Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . Commercial Safety Sockets. . . . . . . . . . . . . . . . . . CH Style Renovation Solutions . . . . . . . . . . . . . . . Aluminum Meter Breakers . . . . . . . . . . . . . . . . . . Page 5 V1-T5-37 5 V1-T5-39 5 V1-T5-48 5 V1-T5-65 V1-T5-75 V1-T5-83 V1-T5-86 V1-T5-87 5 5 5 5 5 5 West Coast All-In-One Design 5 Product Description 5 A metering device that may contain a meter socket, main breaker and distribution section within the same enclosure. Features, Benefits and Functions ● ● ● ● ● ● 5 Semi-flush mounting. 7-inch design ideal for stucco homes Endwall knockouts are easily accessible for future wiring without damaging stucco Knockout in back of case for mounting car-charging receptacle in garage (meets future electric car requirements) Outboard split neutral for easy wiring Commercial grade main breaker Value-added kits available: Hub adapter plate 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-59 5.9 5 5 Metering Products Meter Breakers Product Selection MBED3042B200BF 7-Inch Deep Meter Breaker—Standard Design OH/NG Main Branch Breaker Type Catalog Number— Flush FactoryInstalled Kits BW2100 BR MBED1836B100BF — BW2125 BR MBED1836B125BF — 20/40 BW2200 BR MBED2040B200BF — 20/40 BW2200 BR MBED2040B200BFN — 4 30/42 BW2200 BR MBED3042B200BF — 10 4 20/40 BW2225 BR MBED2040B225BF — UG 10 4 20/40 BW2225 BR MBED2040B225BFN — UG 10 4 30/42 BW2225 BR MBED3042B225BF — 5 Ampere Rating Bypass Service kAIC Jaws Distribution 5 100 None UG 10 4 18/36 125 None UG 10 4 18/36 5 200 None UG 10 4 5 200 1 None UG 10 4 200 None UG 10 5 225 None UG 225 1 None 5 225 None 5 Accessories 5 5 Hub Adapter Plate 5 Description Catalog Number Hub adapter plate MBEDADPT 5 Note 1 Main Breaker Bus connected to 20/40 distribution. Main and Disconnect in same compartment. 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 V1-T5-60 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Meter Breakers 5.9 Wiring Diagrams Typical Wiring Diagram for Catalog Numbers MBED3042B200BF, MBED3042B225BF, MBED3042BH200BF 5 Typical Wiring Diagram for Catalog Numbers MBED2040B200BFN, MBED2040B225BFN 5 5 5 5 5 5 5 5 5 5 Typical Wiring Diagram for Catalog Numbers MBED1836B100BF, MBED1836B125BF Typical Wiring Diagram for Catalog Numbers MBED2040B200BF, MBED2040B225BF, MBED2040BH200BF, MBED2040BH225BF 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-61 5.9 5 Metering Products Meter Breakers Typical Wiring Diagram for Catalog Numbers MBEB2003040BB and MBEB2253040BB 5 Loadcenter Main Lugs 5 A 5 B Loadcenter Neutral N 5 5 A B A B 5 5 5 5 Line N 5 200A or 225A Max. Service Disconnect Type BW or CSR Factory Bonded Neutral Wiring Diagram Key #14-2/0 AWG #6-250 AWG 5 5 5 5 5 Dimensions and Knockouts Approximate Dimensions in Inches (mm) 7-Inch Deep Meter Breaker 5 Catalog Number— Flush Height Width Depth 5 MBED1836B100BF 38.00 (965.2) 14.19 (360.4) 7.00 (177.8) MBED1836B125BF 38.00 (965.2) 14.19 (360.4) 7.00 (177.8) 5 MBED2040B200BF 38.00 (965.2) 14.19 (360.4) 7.00 (177.8) MBED2040B200BFN 42.50 (1079.5) 14.19 (360.4) 7.00 (177.8) 5 MBED3042B200BF 42.50 (1079.5) 14.19 (360.4) 7.00 (177.8) 5 MBED2040B225BF 38.00 (965.2) 14.19 (360.4) 7.00 (177.8) MBED2040B225BFN 42.50 (1079.5) 14.19 (360.4) 7.00 (177.8) MBED3042B225BF 42.50 (1079.5) 14.19 (360.4) 7.00 (177.8) 5 5 5 5 5 5 5 5 5 V1-T5-62 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Meter Breakers 5.9 Approximate Dimensions in Inches (mm) 5 Catalog Numbers MBED2040B200BFN, MBED20408225BFN, MBED3042B200BF, MBED3042B225BF, MBED2040B200BF, MBED2040B225BF, MBED1836B100BF, MBED1836B125BF 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Knockout Configurations and Dimensions for MBED2040B200BFN, MBED20408225BFN, MBED3042B200BF, MBED3042B225BF, MBED2040B200BF, MBED2040B225BF,MBED1836B100BF, MBED1836B125BF 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-63 5.9 5 5 Metering Products Meter Breakers Approximate Dimensions in Inches (mm) Catalog Numbers MBEB2003040BB, MBEB2253040BB 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Knockout Configurations for MBEB2003040BB, MBEB2253040BB 5 5 5 5 5 5 5 5 5 5 5 5 V1-T5-64 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Meter Breakers 5.9 Contents Mechanical Interlock Cover Description Residential Meter Breakers . . . . . . . . . . . . . . . . . . Non-EUSERC Combination Service Entrance Devices 100–200A Styles . . . . . . . . . . . . . . . . . . Meets EUSERC Requirements Service Entrance Devices 100–225A . . . . . . . . . . . . . . . . . . . . . . . West Coast All-In-One Design. . . . . . . . . . . . . . . . Mechanical Interlock Cover House Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . Commercial Safety Sockets. . . . . . . . . . . . . . . . . . CH Style Renovation Solutions . . . . . . . . . . . . . . . Aluminum Meter Breakers . . . . . . . . . . . . . . . . . . Page 5 V1-T5-37 5 V1-T5-39 5 V1-T5-48 V1-T5-59 V1-T5-75 V1-T5-83 V1-T5-86 V1-T5-87 5 5 5 5 5 5 Meter Breaker with Interlock Cover 5 Mechanical Interlock Cover 5 Product Description 5 Covers mechanically interlock two breakers. Covers interlock main breaker with two-pole breaker mounted in the distribution section of the meter breakers. 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-65 5.9 5 5 Metering Products Meter Breakers Product Selection Meter Breaker with Interlock Cover Mechanical Interlock Cover Mechanical Interlock Deadfront Meter Breaker Catalog Number Mechanical Interlock Deadfront Meter Breaker Catalog Number MBDF1M CMB1212B200BTS MBDF1AM CMB2424M200BTS 5 CMB1212B200BTSD MBDF10M CMB24B200TFR 5 CMB1212P200BTSD 5 CMB1212P200BTS MBDF2M 5 MB816B200BTS MB816B200BTSCU 5 CMB24B200TSR MBDF11M CMBXP200BTS MBDF12M MB816P200BTS MB816P200BTSCU 5 5 5 MBDF4M 5 MBDF5M 5 MB2040B200BTS 5 MBDF6M 5 MBDF7M MBE3042B225BF MBDF14M CMBE88B150BTF CMBE88B150BTS MB2040P200SD CMBE88B200BTF MBE816P200TS CMBE88B200BTS MBE816P200TSCU CMB88B150BTS MBE2040B150BF CMB88B200BTS MBDF15M MBE48B150BTF MBE2040B200BF MBE48B150BTS MBE2040B200BS MBE48B200BTF MBE2040B200TF MBE2040B200TS 5 MBE3042B200BF MB2040P200BTS MBE2040B150BS 5 CMBX3242B200BTS CMBX3242P200BTS MBDF13M MB816P200STD MBDF3M CMBXB200BTS MBE48B200BTS MBDF16M MBE88B150BTF MBE2040P200TF MBE88B150BTS MBE2040P200TS MBE88B200BTF CMBE3242B150BF MBE88B200BTS 5 CMBE3242B150BS CMBE3242B200BF MBE2040BH200BTF 5 CMBE3242B200BS MBE2040BH200BTS CMB3242B150BS MBE2040B150BTF CMB3242B200BS MBE2040B150BTS CMBE4242B200BSH MBE2040B200BTF CMBE4242B200BTF MBE2040B200BTS CMBE4242B200BTS MBE2040B200BTSV MBE4040B200BSH MBE2040B225BTF 5 MBE4040B200BSHH MBE2040B225BTS 5 MBE4040B200BTS 5 MBDF8M 5 5 MBDF9M MBDF17M MBE2040BC200BTS MBE4040B200BTF 5 5 5 5 5 5 5 V1-T5-66 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Meter Breakers Meter Breaker Parts 1 Catalog Number Description 5th Jaw Kits Technical Data and Specifications 5 Wire Size Chart 5 Main Wire Size Range Cu/Al 60ºC or 75ºC for Line Terminals BR250 #14–4 kcmil Compact and standard styles (MB and CMB) MB5JAWKIT BR260 #4–1/0 kcmil EUSERC style IMM5JKOP BR270 #4–1/0 kcmil BR280 #4–1/0 kcmil BR290 #4–1/0 kcmil BR2100 #4–1/0 kcmil BW2125 #2–300 kcmil BW2150 #2–300 kcmil Horn Bypass Kits Ringless Style units only (MB and CMB) MBHBPKIT Hub Selection Chart Hub Size Dimensions in Inches (mm) Catalog Number BW2200 #2–300 kcmil 1.00 (25.4) DS100H2 CSR2125 #2–300 kcmil 1.25 (31.8) DS125H2 CSR2150 #2–300 kcmil 1.50 (38.1) DS150H2 CSR2200 #2–300 kcmil 2.00 (50.8) DS200H2 CSR2125N #1/0–250 kcmil 2.50 (63.5) DS250H2 CSR2150N #1/0–250 kcmil DS300H2 CSR2200N #1/0–250 kcmil 125A main lugs — 200A main lugs — MCBK225 #2–300 kcmil 3.00 (76.2) Top Endwall (Surface) 5.9 5 5 5 5 5 5 5 5 5 5 5 Hub Provision Catalog Number 5 Wire Size is Determined by the Circuit Breaker Installed in the Enclosure DS100H2 DS125H2 Maximum DS150H2 DS200H2 Wire/Application Wire Size Ampere Rating DS250H2 Aluminum—Standard 250 kcmil 200 DS300H2 Aluminum—Service Entrance 250 kcmil 225 Copper—Standard and Service Entrance 250 kcmil 225 DS900AP (Adapter Plate if using DS___H1 hubs only) 2 5 5 5 5 Notes 1 For breakers under 70A used in backfed applications, add “B” to the end of the catalog string to get the appropriate “hold-down” version. 2 Use when DS H1 Type 1, 1.25 and 1.50-inch hubs are needed. Use DS...H2 hubs for bottom endwalls (for all units). Use RH hubs for top endwalls on semi-flush units. Use DS...H2 hubs for top endwalls on surface devices. 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-67 5.9 5 5 Metering Products Meter Breakers Dimensions and Knockouts Approximate Dimensions in Inches (mm) Box Styles—Five Different Styles (Shapes) of Product 5 B A C D E 5 5 5 5 5 Box Dimensions 5 Box Number Height Width Depth Box Style 5 1 12.50 (317.5) 14.44 (366.7) 4.00 (101.6) A 2 23.88 (606.4) 14.44 (366.7) 5.38 (136.5) A 5 3 28.38 (720.7) 14.44 (366.7) 5.38 (136.5) A 5 4 34.13 (866.8) 14.44 (366.7) 5.38 (136.5) B 5 36.13 (917.6) 14.44 (366.7) 5.38 (136.5) B 5 6 43.38 (1101.7) 14.44 (366.7) 5.38 (136.5) B 7 46.88 (1190.6) 14.44 (366.7) 5.38 (136.5) B 5 8 19.75 (501.7) 7.50 (190.5) 4.00 (101.6) C 9 25.00 (635.0) 14.44 (366.7) 5.38 (136.5) C 5 10 32.38 (822.3) 14.44 (366.7) 5.38 (136.5) C 5 11 36.63 (930.3) 14.44 (366.7) 5.38 (136.5) C 12 34.38 (873.1) 22.00 (558.8) 5.38 (136.5) D 5 13 19.75 (501.7) 14.44 (366.7) 5.38 (136.5) E 14 39.91 (1013.7) 14.44 (366.7) 5.38 (136.5) C 5 15 23.88 (606.6) 13.00 (330.2) 4.94 (125.5) F 5 16 28.38 (720.9) 13.00 (330.2) 4.94 (125.5) F 17 34.19 (868.4) 22.13 (562.1) 5.00 (127.0) D 5 18 36.06 (915.9) 16.63 (422.4) 5.50 (139.7) A 19 28.38 (720.9) 14.44 (366.8) 4.94 (125.5) A 5 20 32.06 (814.3) 14.44 (366.8) 4.94 (125.5) C 21 25.50 (647.7) 14.44 (366.8) 4.94 (125.5) C 5 5 5 5 5 5 5 5 5 V1-T5-68 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com F Metering Products Meter Breakers 5.9 Approximate Dimensions in Inches (mm) Knockouts for Stucco and Surface Units Catalog Numbers— CMBE3242B200BF, CMBE3242B225BF, MBE2040B200BF, MBE2040B150BF, MBE1428B100BF, MBE1212L200BTF, MBE1836B125BF and MBE1212L200BTS 62a. Keyhole Knockouts on Sides for Stucco Units Only. 3-1/2 88.9 (88.9) Hub Provision Catalog Number 4-15/16 (125.4) Quantity DS100H2 1 DS125H2 1 DS150H2 1 DS200H2 1 DS250H2 1 DS300H2 1 DS900AP Top T op Stucco 5 Top Endwall (Surface) (Adapter Plate if using DS___H1 hubs only) 2 5 5 5 5 1 5 5 Top Endwall (Stucco) 3 Knockout Size Dimensions in Inches (mm) Quantity 1.25, 1.50, 2.00, 2.50 (31.8, 38.1, 50.8, 63.5) 1 1.00, 1.25, 1.50 (25.4, 31.8, 38.1) 1 0.50, 0.75, 1.00 (12.7, 19.1, 25.4) 1 0.50, 0.75 (12.7, 19.1) 3 0.50 (12.7) 3 5-5/16 (134.9) 5 5 5 5 Bottom Knockouts for Stucco and Surface Units Catalog Numbers— CMBE3242B150BS, CMBE3242B200BS, CMBE3242B225BS, CMBE1212L200BS, MBE2040B200BS, MBE1428B100BS, MBE1212L200BTS, CMB3242B150BS and CMB3242B200BS 62b. 5 5 Bottom Endwall Knockout Size Dimensions in Inches (mm) Quantity 0.50 (12.7) 7 0.50, 0.75 (12.7, 19.1) 4 0.50, 0.75, 1.00 (12.7, 19.1, 25.4) 1 1.00, 1.25, 1.50, 2.00 (25.4, 31.8, 38.1, 50.8) 1 1.25, 1.50, 2.00, 2.50, 3.00 (31.8, 38.1, 50.8, 63.5, 76.2) 1 5 5 5 5 Notes 1 For details regarding quantities, please contact the Technical Resource Center (TRC) at 1-877-ETN-CARE. 2 Use when DS H1 Type 1, 1.25 and 1.50-inch hubs are needed. 3 RH hubs are to be used for Top Endwall (Stucco) endwalls. Top Surface 5 5 5 5 5 5 4-15/16 (125.4) 5 5 Bottom 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-69 5.9 5 5 5 Meter Breakers Approximate Dimensions in Inches (mm) Knockouts for Stucco and Surface Units Catalog Numbers— CMBE88B150BTF, CMBE88B200BTF, MBE24L125BTF, MBE24L200BTF, MBE48B200BTF, MBEB200BTF, MBE1224B100BTF and MBE1224B125BTF 63a. Keyhole Knockouts on Sides for Stucco Units Only. 5 5 Metering Products 3-1/2 (88.9) 5 Top Endwall (Surface) Hub Provision Catalog Number DS100H2 1 DS125H2 1 DS150H2 1 DS200H2 1 DS250H2 1 1 DS300H2 DS900AP 5 5 Top Stucco Quantity (Adapter Plate if using DS___H1 hubs only) 2 1 Top Endwall (Stucco) 3 5 Knockout Size Dimensions in Inches (mm) 5 1.25, 1.50, 2.00, 2.50 (31.8, 38.1, 50.8, 63.5) 1 1.00, 1.25, 1.50 (25.4, 31.8, 38.1) 1 0.50, 0.75, 1.00 (12.7, 19.1, 25.4) 1 0.50, 0.75 (12.7, 19.1) 3 0.50 (12.7) 3 5 4-15/16 (125.4) 5 Bottom 5 5 5 5 5 Knockouts for Stucco and Surface Units Catalog Numbers— CMBB150BTS, CMBB200BTS, CMBP200BTS, CMBE24L125BTS, CMB24L125BTS, CMBE24L200BTS, CMBEB200BTS, CMBEB150BTS, CMBE88B150BTS, CMBP200BTS, CMBE88B200BTS, MBE24L125BTS, MBE24L200BTS, MBE48B150BTS, MBE48B200BTS, MBE88B200BTS, MBEB200BTS, MBE1224B100BTS, MBE1224B125BTS, CMB88B150BTS, CMB88B200BTS and MB48B200BTS 63b. 5 5 5 Bottom Endwall Knockout Size Dimensions in Inches (mm) 7 0.50, 0.75 (12.7, 19.1) 4 0.50, 0.75, 1.00 (12.7, 19.1, 25.4) 1 1.00, 1.25, 1.50, 2.00 (25.4, 31.8, 38.1, 50.8) 1 1.25, 1.50, 2.00, 2.50, 3.00 (31.8, 38.1, 50.8, 63.5, 76.2) 1 Notes 1 For details regarding quantities, please contact the Technical Resource Center (TRC) at 1-877-ETN-CARE. 2 Use when DS H1 Type 1, 1.25 and 1.50-inch hubs are needed. 3 RH hubs are to be used for Top Endwall (Stucco) endwalls. 5-5/16 (134.9) 5 Top Surface 5 5 4-15/16 (125.4) 5 Bottom 5 5 5 5 V1-T5-70 Quantity 0.50 (12.7) 5 5 Quantity Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Meter Breakers 5.9 Approximate Dimensions in Inches (mm) Knockouts for Stucco and Surface Units Catalog Number— MMBE2040B200TF 64a. Keyhole Knockouts on Sides for Stucco Units Only. Knockouts for Stucco and Surface Units Catalog Numbers— MBE1224B100TS, MBE1224B125TS, MBE816P200TS, MBE816P200TSCU, MBE2040B200TS, CMB1212P200BTS, CMB1212P200BTSD, CMB1212B200BTS, MB1212L200BTS and CMB1212L200BTS 64b. 5 5 5 3.50 (88.9) 5 5.31 (134.9) 5 5 Top Stucco 5 Top Surface 5 4.94 (125.4) 5 4.94 (125.4) 5 Bottom 5 Bottom Top Endwall (Surface) Hub Provision Catalog Number Quantity DS100H2 1 DS125H2 1 DS150H2 1 DS200H2 1 DS250H2 1 DS300H2 1 DS900AP 5 (Adapter Plate) 2 1 Knockout Size Dimensions in Inches (mm) Quantity 0.50 (12.7) 7 0.50, 0.75 (12.7, 19.1) 4 0.50, 0.75, 1.00 (12.7, 19.1, 25.4) 1 1.00, 1.25, 1.50, 2.00 (25.4, 31.8, 38.1, 50.8) 1 1.25, 1.50, 2.00, 2.50, 3.00 (31.8, 38.1, 50.8, 63.5, 76.2) 1 1 1.00, 1.25, 1.50 (25.4, 31.8, 38.1) 1 0.50, 0.75, 1.00 (12.7, 19.1, 25.4) 1 0.50, 0.75 (12.7, 19.1) 3 0.50 (12.7) 3 5 5 Quantity 1.25, 1.50, 2.00, 2.50 (31.8, 38.1, 50.8, 63.5) 5 5 Notes 1 For details regarding quantities, please contact the Technical Resource Center (TRC) at 1-877-ETN-CARE. 2 Use when DS H1 Type 1, 1.25 and 1.50-inch hubs are needed. 3 RH hubs are to be used for Top Endwall (Stucco) endwalls. Top Endwall (Stucco) 3 Knockout Size Dimensions in Inches (mm) 5 Bottom Endwall 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-71 5.9 5 5 5 Metering Products Meter Breakers Approximate Dimensions in Inches (mm) Knockouts for Stucco and Surface Units 3.44 (87.3) 5 5 Top Flush MBE4040B200BTF 5 5 5 5.31 (134.9) 5.31 (134.9) 5 Top Surface 5 Top Surface 2-1/2-inch Hub 5 5 4.94 (125.4) 4.94 (125.4) 5 5 5 5 5 Bottom Bottom CMBE4242B200BTS MBE4040B200BTS MBE4040B200BSH Bottom Endwall Top Endwall (Surface) Hub Provision Catalog Number Quantity Knockout Size Dimensions in Inches (mm) Quantity DS100H2 1 0.50, 0.75 (12.7, 19.1) 6 5 DS125H2 1 0.50, 0.75, 1, 1.25 (12.7, 19.1, 25.4, 31.8) 2 1 5 DS150H2 1.00, 1.25, 1.50, 2.00, 2.50 (25.4, 31.8, 38.1, 50.8, 63.5) 1 DS200H2 1 1.00, 1.25, 1.50, 2.00, 2.50, 3.00 (25.4, 31.8, 38.1, 50.8, 63.5, 76.2) 1 5 DS250H2 1 DS300H2 1 5 DS900AP (Adapter Plate) 2 1 5 Top Endwall (Stucco) 3 5 Knockout Size Dimensions in Inches (mm) Quantity 5 1.25, 1.50, 2.00, 2.50 (31.8, 38.1, 50.8, 63.5) 2 0.50, 0.75 (12.7, 19.1) 3 5 Notes 1 For details regarding quantities, please contact the Technical Resource Center (TRC) at 1-877-ETN-CARE. 2 Use when DS H1 Type 1, 1.25 and 1.50-inch hubs are needed. 3 RH hubs are to be used for Top Endwall (Stucco) endwalls. 5 5 5 5 5 V1-T5-72 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Meter Breakers 5.9 Approximate Dimensions in Inches (mm) Knockout Configurations and Dimensions for Catalog Numbers MBER48B200BTS and CMBER88B200BTS 66a. Semi-Flush Stucco Unit Knockout Configurations and Dimensions for MBE2040B200BTS, MBE2040B225BTS, MBE2040B200BTF and MBE2040B225BTF 66d. 5 5 5 5 5-5/16" 5 Top Surface 5 5 5 4-15/16" 5 5 Bottom End Mounting Surface Knockout Configurations and Dimensions for Catalog Numbers CMBXP200BTS, CMBXB200BTS, CMBX1212P200BTS and CMBX3242P200BTS, CMBX3242B200BTS, CMBX1212B200BTS 66b. 5 Knockout Configurations and Dimensions for Catalog Numbers MBT48B125BTS, MBT48B150BTS, MBT48B200BTS and MBT48P200BTS 66e. 5 5 5 5 5-5/16" 5 5 Top Surface 5 5 4-15/16" 5 5 Bottom 5 5 Surface Unit Knockout Configurations and Dimensions for MBE2040B200BTS, MBE2040B225BTS, MBE2040B200BTF and MBE2040B225BTF 66c. 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-73 5.9 5 5 5 5 Metering Products Meter Breakers Approximate Dimensions in Inches (mm) Knockouts for Non-EUSERC Units Catalog Numbers— MBB150BTS, MBB200BTS, MBP200BTS, MB816P200BTS, MB816P200BTSCU, MB816P200BTSD, MB816B200BTS, MB816B200BTSCU, MB2040P200BTS, MB2040B200BTS, MBP200BTSD, MBP200SD, MB816P200STD, MB2040B150SD, MB2040B200SD and MB2040P200SD 67a. Knockouts for Non-EUSERC Units Catalog Numbers— CMB2424B200BTS, MBB150BTSCR, MBB200BTSCR, MBB150BTSC, MBB200BTSC and CMB2436B200BTS 67c. 5 5 5.31 (134.9) 5.31 (134.9) 5 5 Top Surface (Catalog Numbers with SC and SCR Suffix Only) Top Surface 5 5 5 4.94 (125.4) 4.94 (125.4) 5 Bottom Bottom 5 Top Endwall (Surface) 5 Hub Provision Catalog Number Bottom Endwall Quantity Knockout Size Dimensions in Inches (mm) Quantity DS100H2 1 0.31 (7.9) 3 DS125H2 1 0.50 (12.7) 3 DS150H2 1 0.50, 0.75 (12.7, 19.1) 2 5 DS200H2 1 0.75, 1.00 (12.7, 25.4) 1 DS250H2 1 1.25, 1.50, 2.00, 2.50 (19.1, 38.1, 50.8, 63.5) 2 5 DS300H2 1 1.50, 2.00, 2.50, 3.00 (38.1, 50.8, 63.5, 76.2) 1 5 5 5 5 DS900AP (Adapter Plate) 1 2 Knockouts for Non-EUSERC Units Catalog Number— CHMMB100BTS 67b. 5 5 5 Knockouts for Non-EUSERC Units Catalog Numbers— CHMMB150BTS and CHMMB200BTS 67d. 4.94 (125.4) 4.94 (125.4) Bottom 5 Bottom Bottom Endwall 5 Bottom Endwall Knockout Size Dimensions in Inches (mm) Quantity 5 Knockout Size Dimensions in Inches (mm) Quantity 0.31 (7.9) 1 5 0.31 (7.9) 1 5 0.50 (12.7) 1 0.50, 0.75, 1.00, 1.25, 1.50, 2.00, 2.50 (12.7, 19.1, 25.4, 31.8, 38.1, 50.8, 63.5) 2 1,00, 1.25, 1.50, 2.00, 2.50 (25.4, 31.8, 38.1, 50.8, 63.5) 1 5 5 V1-T5-74 0.50 (12.7) 1 0.50, 0.75, 1.00, 1.25, 1.50, 2.00, 2.50 (12.7, 19.1, 25.4, 31.8, 38.1, 50.8, 63.5) 2 1.00, 1.25, 1.50, 2.00, 2.50, 3.00 (25.4, 31.8, 38.1, 50.8, 63.5, 76.2) 1 Notes 1 For details regarding quantities, please contact the Technical Resource Center (TRC) at 1-877-ETN-CARE. 2 Use when DS H1 Type 1, 1.25 and 1.50-inch hubs are needed. Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Meter Breakers 5.9 Contents House Panels Description Page Residential Meter Breakers . . . . . . . . . . . . . . . . . . Non-EUSERC Combination Service Entrance Devices 100–200A Styles . . . . . . . . . . . . . . . . . . Meets EUSERC Requirements Service Entrance Devices 100–225A . . . . . . . . . . . . . . . . . . . . . . . West Coast All-In-One Design. . . . . . . . . . . . . . . . Mechanical Interlock Cover . . . . . . . . . . . . . . . . . . House Panels Commercial Safety Sockets. . . . . . . . . . . . . . . . . . CH Style Renovation Solutions . . . . . . . . . . . . . . . Aluminum Meter Breakers . . . . . . . . . . . . . . . . . . 5 V1-T5-37 5 V1-T5-39 5 V1-T5-48 V1-T5-59 V1-T5-65 V1-T5-83 V1-T5-86 V1-T5-87 5 5 5 5 5 5 5 5 House Panels Product Description Application Description Eaton’s House Panels offer a faster, easier and safer installation.These 400A units are ideal for larger homes in North America that require meter breakers. Available in both CH and BR styles, these service entrance devices consist of a meter socket and a distribution section. In response to contractor feedback, these panels have been redesigned with a focus on flexibility, simplified wiring, and an overall ease of installation. All units come standard with a 22 kAIC main breaker.The load conductors can exit the top, bottom, side or back for greater application and installation flexibility. Additionally, Eaton’s House Panels can be used for apartments, condominiums, clubhouses or common areas. Features, Benefits and Functions ● ● ● ● ● ● NEMA 3R rainproof Rated for service entrance equipment Lever bypass socket available on certain catalog numbers Pin type door hinges Socket to distribution section is connected via insulated cable for safety Second main space can accept 100–200A BW, CSR or CSR breakers Standards and Certifications ● ● Ring style units meet EUSERC requirements UL listed 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-75 5.9 5 5 Metering Products Meter Breakers Product Selection House Panels 400A “House Panels” 5 5 Ampere Rating 5 Security 1 Bypass 2 Main Breaker Optional Secondary Main Breaker (Not Included) Service Type kAIC Dist. 300 Ringless Lever CSR2150 BW/CSR OH/UG 22 8/16 5 300 Ringless Lever CSR2150 BW/CSR UG 22 None 5 400 Ring None CSH2200N CSR UG 22 400 Ring None CSH2200N CSR UG 22 5 400 Ring Manual CSR2200 BRH/CSR UG 400 Ring Manual CSR2200 BRH/CSR 5 400 Ringless None DK2400 400 Ringless None CSR2200 5 400 Ring None DK2400 None UG 5 400 Ring None CSR2200 BRH/CSR UG 400 Ring None DK2400 None UG 5 400 Ring None CSR220 BRH/CSR UG 400 Ring Manual CSR2200 BRH/CSR UG 5 400 Ring None CSR2200 BRH/CSR 400 Ringless Lever CSH2200N CSR Line Side Main Lugs and Neutral (Lugs Not Included) Lug landings for compression SemiFlush Catalog Number 3 Surface Catalog Number — HP816P400BSL — HPC30SHL 32/42 — CG403242SH 12/12 — CG1212P400BS 5 22 None — HP40SHA 8 UG 22 40/40 — HP404040SHA 68 None UG 22 24/40 — HP402440B 7 BRH/CSR UG 22 24/40 — HP402440SBH 78 22 None — HP40 22 None — HP40SH 8 22 24/42 — HP402442 22 40/40 HP404040SHF HP404040SH 8 22 40/40 HP404040SHFA 6 — UG 22 8/16 — HP816P400BS 58 UG 22 12/12 — CG1212P400BSL 5 5 400 Ringless Lever CSH2200N CSR UG 22 42/42 — CG404242SHL 5 400 Ringless Lever CSR2200 BRH/CSR UG 22 None — HP40SHL 8 400 Ringless Lever CSR2200 BRH/CSR OH/UG 22 None — HPC40SHL 8 5 400 Ringless Lever CSR2200 BRH/CSR UG 22 40/40 — HP404040SHL 8 400 Ringless Lever CSR2200 BRH/CSR UG 22 8/16 — HP816P400BSL 58 5 400 Ringless Lever CSR2200 BRH/CSR OH/UG 22 4/6 — HPC4046SHLG 9 400 Ringless Lever CSR2200 BRH/CSR OH/UG 22 4/6 — HPC4046SHLX j 5 Notes 1 Confirm security type for individual EUSERC utility requirements. 2 Included in all of the following devices. 3 If unit needs to be semi-flush, order accessory item catalog number HPPR to convert all surface mounting devices to semi-flush mounting. 4 Secondary sub-main installed in panel. 5 Feed-through lugs included. 6 Includes manual bypass and additional ground lug to meet Nevada Power requirements. 7 Bolt-on meter socket. 8 For 10 kAIC, use BR or BW breakers as secondary main. 9 Georgia Power approved. j Xcel approved. 5 5 5 5 5 5 5 5 5 5 5 5 V1-T5-76 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Meter Breakers 5.9 Accessories ● ● ● ● 5 Top-feed gutter kit to ease top-fed installation Re-engineered, adjustable flush mount kit for a cleaner installation 100A second main breaker kit New 750 kcmil box type lug kit 5 5 5 5 5 Accessories HP40TFKIT Description Catalog Number Top feed kit to convert surface mount house panel for overhead service HP40TFKIT 5 5 5 5 5 5 5 HPBLK750 750 kcmil lug kit 5 HPBLK750 5 HPBPK Manual bypass kit 5 HPBPK 5 5 HP2NDMNKIT Flushmount kit HPPR 100A 2nd main kit (Type BR branch) HP2NDMNKIT 100A 2nd main kit (Type CH branch) CH2NDMNKIT 5th jaw for lever bypass house panels ARP00326CH Locates 3-inch (only) incoming conduit to back of can by utilizing the 4-inch knockout useful in semi-flush applications HP40HUBPLATE 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-77 5.9 Metering Products Meter Breakers 5 Wiring Diagrams 5 Type CH Style House Panels 5 Type CH Wiring—Catalog Number CG403242SH 5 5 A N 400 AMPERES (320 AMPERES CONTINUOUS) 1 2 3 4 5 6 7 8 B LINE 5 9 10 11 12 13 14 15 16 18 20 21 22 24 26 28 30 32 34 36 38 40 42 17 5 19 23 25 27 29 31 33 35 37 39 41 5 5 FACTORY/FIELD INSTALLED 100 A MAXIMUM SERVICE DISCONNECT TYPE CH OPTIONAL 200 A MAXIMUM SERVICE DISCONNECT TYPE BW OR CSR AMPERES (CONTINUOUS) EQUIPMENT GROUNDING TERMINALS A N B LINE 5 A N LINE B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 17 16 18 19 20 5 21 22 23 24 25 26 5 27 29 28 31 32 33 34 35 36 37 38 39 40 41 42 5 5 5 5 30 7 8 9 10 11 12 FACTORY/FIELD INSTALLED 200 A MAXIMUM SERVICE DISCONNECT FACTORY/FIELD INSTALLED 100 A MAXIMUM SERVICE DISCONNECT TYPE CH 400 AMPERES (320 AMPERES CONTINUOUS) A N B LINE 1 3 5 7 9 11 100 A MAX. SERVICE DISCONNECT TYPE CH 2 4 6 8 10 12 BONDED NEUTRAL EQUIPMENT GROUNDING TERMINALS BONDED NEUTRAL OPTIONAL 200 A MAX. SERVICE DISCONNECT TYPE CSR OPTIONAL 200 A MAXIMUM SERVICE DISCONNECT TYPE BW OR CSR Type CH Wiring Diagram Key #14-6 AWG #14-1/0 AWG 1/0 – 300 kcmil #4 AWG – 300 kcmil 5 5 5 5 5 5 V1-T5-78 6 Type CH Wiring—Catalog Number CG1212P400BSL FACTORY INSTALLED 200 A SERVICE DISCONNECT TYPE CSR 400 AMPERES (320 AMPERES CONTINUOUS) 5 2 4 5 BONDED NEUTRAL (OPTIONAL) 5 1 3 BONDED NEUTRAL Type CH Wiring—Catalog Number CG404242SHL 5 5 FACTORY/FIELD INSTALLED 200 A MAXIMUM SERVICE DISCONNECT TYPE CSR FACTORY INSTALLED 200 A SERVICE DISCONNECT 5 5 OPTIONAL 200 A MAX. SERVICE DISCONNECT TYPE CSR 100 A MAX. SERVICE DISCONNECT TYPE CH (OPTIONAL) 5 5 Type CH Wiring—Catalog Number CG1212P400BS Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Meter Breakers 5.9 Type BR Style House Panels 5 Type BR Wiring—Catalog Number HP40 F ACTOR Y INSTALLED 400 A SER VICE DISCONNECT TYPE DK A N B 5 100 A MAX. SERVICE DISCONNECT 1 3 5 7 9 11 13 15 LINE N (OPTIONAL) 200 A MAX. SERVICE DISCONNECT TYPE BW OR CSR FACTORY INSTALLED 200 A MAX. SERVICE DISCONNECT TYPE CSR 400 AMPS (320 AMPS CONTINUOUS) 400 AMPERES (320 AMPERES CONTINUOUS) A 5 Type BR Wiring—Catalog Number HP816P400BS 5 2 4 6 8 10 EQUIPMENT 12 GROUNDING 14 TERMINALS 16 5 5 BONDED NEUTRAL B 5 LINE BONDED NEUTRAL 5 5 Type BR Wiring—Catalog Number HP402440B 5 Type BR Wiring—Catalog Number HP402440SBH FACTORY INSTALLED 400 A SERVICE DISCONNECT TYPE DK 400 AMPS (320 AMPS CONTINUOUS) A N B LINE (OPTIONAL) 1 2 3 4 5 6 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 N B LINE BONDED NEUTRAL 5 100 A MAX. SERVICE DISCONNECT TYPE BRH OR BR 400 AMPS (320 AMPS CONTINUOUS) A 5 FACTORY/FIELD INSTALLED 200 A MAX. SERVICE DISCONNECT TYPE CSR OR BW FACTORY INSTALLED 200 A SERVICE DISCONNECT TYPE CSR 1 2 3 4 5 6 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 5 5 BONDED NEUTRAL 5 5 5 Type BR Wiring—Catalog Number HP404040SH 5 Type BR Wiring Diagram Key 5 #14-6 AWG (OPTIONAL) FACTORY/FIELD INSTALLED 200 A MAXIMUM SERVICE DISCONNECT TYPE CSR OR BW FACTORY INSTALLED 200 A SERVICE DISCONNECT TYPE CSR 400 AMPERES 1 (320 AMPERES 3 CONTINUOUS) 5 A N LINE B 7 9 100 A MAXIMUM SERVICE DISCONNECT TYPE BRH OR BR 5 #14-1/0 AWG #6 AWG – 250 kcmil 5 #1 AWG – 300 kcmil 5 2 4 6 EQUIPMENT 8 GROUNDING TERMINALS 10 11 12 13 14 15 16 17 18 19 20 21 22 23 25 24 26 27 28 29 30 31 32 33 34 35 36 37 39 38 BONDED NEUTRAL 1/0 – 300 kcmil #4 AWG – 300 kcmil 5 #6 AWG – 300 kcmil 5 5 5 40 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-79 5.9 5 Meter Breakers Type BR Wiring—Catalog Number HP402442 5 FACTORY INSTALLED BY-PASS. 400 AMPERES (320 AMPERES CONTINUOUS) A N 1 B LINE 5 5 5 5 3 4 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 FACTORY INSTALLED 200 A SERVICE DISCONNECT TYPE CSR 400 AMPS (320 AMPS CONTINUOUS) B A LINE 1 2 3 BONDED NEUTRAL 5 7 4 9 10 11 12 N 14 5 17 16 18 19 20 21 22 5 25 26 27 28 29 30 31 32 5 33 34 35 36 37 38 39 40 23 BONDED NEUTRAL GROUNDING LUG 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 33 32 34 35 37 36 38 39 40 OPTIONAL 200 A MAX. SERVICE DISCONNECT TYPE CSR FACTORY/FIELD INSTALLED 200 A MAX. SERVICE DISCONNECT TYPE BW OR CSR 100 A MAX. SERVICE DISCONNECT TYPE BR OR BHR FACTORY INSTALLED 200 A MAX. SERVICE DISCONNECT 400 AMPS (320 AMPS CONTINUOUS) A N B LINE 100 A MAX. SERVICE DISCONNECT 1 3 5 7 9 11 13 15 2 4 6 8 10 12 14 16 24 Type BR Wiring Diagram Key #14-6 AWG (OPTIONAL) FACTORY/FIELD INSTALLED 200A MAX. SERVICE DISCONNECT TYPE CSR OR BW 100A MAX. SERVICE DISCONNECT TYPE BRH OR BR FACTORY INSTALLED 200 A SERVICE DISCONNECT TYPE CSR 400 AMPS (320 AMPS CONTINUOUS) #6 AWG – 250 kcmil #1 AWG – 300 kcmil 1/0 – 300 kcmil 1/3 – 300 kcmil 1 #4 AWG – 300 kcmil #6 AWG – 300 kcmil A N B LINE BONDED NEUTRAL Type BR Wiring—Catalog Number HP40SHL 5 FACTORY INSTALLED 200 A SERVICE DISCONNECT TYPE CSR 5 400 AMPS (320 AMPS CONTINUOUS) 5 (OPTIONAL) FACTORY/FIELD INSTALLED 200 A MAX. SERVICE DISCONNECT TYPE BW OR CSR 100 A MAX. SERVICE DISCONNECT TYPE BR OR BRH BONDED NEUTRAL A LINE B N 5 5 V1-T5-80 EQUIPMENT GROUNDING TERMINALS BONDED NEUTRAL #14-1/0 AWG 5 5 LINE 1 Type BR Wiring—Catalog Number HP40SH 5 5 9 B 8 15 5 6 EQUIPMENT 8 GROUNDING 10 TERMINALS 7 N 100 A MAX. SERVICE DISCONNECT TYPE BRH OR BR 6 13 5 4 (OPTIONAL) 5 5 2 3 5 2 A 1 Type BR Wiring—Catalog Number HP816P400BSL 5 5 FACTORY/FIELD INSTALLED 200 A MAX. SERVICE DISCONNECT TYPE CSR OR BW Type BR Wiring—Catalog Number HP404040SHL 5 5 (OPTIONAL) FACTORY INSTALLED 200 A SERVICE DISCONNECT TYPE CSR FACTORY INSTALLED 400 A SERVICE DISCONNECT TYPE DK 5 5 Type BR Wiring—Catalog Number HP404040SHA 400 AMPS (320 AMPS CONTINUOUS) 5 5 Metering Products Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Meter Breakers 5.9 Catalog Numbers HPC40SHL and HPC30SHL 5 5 N 400 Amps (320 Amps Continuous) 5 Bonded Neutral 5 (Optional) Factory/Field Installed 150 A Max. - HPC30SHL 200 A Max. - HPC40SHL Service Disconnect Type BW or CSR 5 (Optional) 100 A Max. Service Disconnect Type BR or BRH 5 5 5 Factory Installed 150 A or 200 A Service Disconnect Type CSR 5 5 5 Dimensions and Knockouts 5 Approximate Dimensions in Inches (mm) 5 Catalog Numbers HPC40SHL and HPC30SHL 5 5 5 5 5 5 5 5 5 5 Knockout Configurations and Dimensions for HPC40SHL and HPC30SHL 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-81 5.9 5 5 Metering Products Meter Breakers Approximate Dimensions in Inches (mm) House Panel Dimensions and Knockouts—For All House Panels Except Those With HPCPREFIX 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 V1-T5-82 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Meter Breakers 5.9 Contents Residential Meter Breakers Description Page Residential Meter Breakers. . . . . . . . . . . . . . . . . . Non-EUSERC Combination Service Entrance Devices 100–200A Styles . . . . . . . . . . . . . . . . . . Meets EUSERC Requirements Service Entrance Devices 100–225A . . . . . . . . . . . . . . . . . . . . . . . West Coast All-In-One Design. . . . . . . . . . . . . . . . Mechanical Interlock Cover . . . . . . . . . . . . . . . . . . House Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . Commercial Safety Sockets CH Style Renovation Solutions . . . . . . . . . . . . . . . Aluminum Meter Breakers . . . . . . . . . . . . . . . . . . 5 V1-T5-37 5 V1-T5-39 5 V1-T5-48 V1-T5-59 V1-T5-65 V1-T5-75 V1-T5-86 V1-T5-87 5 5 5 5 5 5 5 5 Commercial Safety Sockets Product Description A Commercial Safety Socket is service entrance equipment that consists of a commercial meter socket with a test block, and may come with or without a loadcenter type distribution section. 5 Features, Benefits and Functions Commercial Safety Sockets with No Secondary Feeder 5 Overhead Combination Units Underground Combination Units 5 5 5 Application Description Eaton’s Commercial Safety Sockets are typically used where a single meter socket or single meter socket with a distribution section are needed. These areas could include a commercial business, commercial office building, individual retail facilities and signs and street lighting. Commercial Safety Sockets are typically used in EUSERC utility regions. 5 5 5 5 ● ● ● ● ● ● ● Ring type continuous duty meter socket. 600 Vac maximum, single- or three-phase 100 and 200A units Bussed connection from meter socket to test block For use with self-contained watthour meter Conform with EUSERC standards NEMA 3R construction for indoor/outdoor applications Units can be individually mounted with provisions for hub kits and pole mounting ● ● ● ● ● ● NEMA 3R construction for indoor/outdoor applications T-fuse protection, 480 Vac maximum Line at top, load at bottom 100 and 200A units available up to 480 Vac maximum Circuit breaker protection to 480 Vac maximum in 10, 22, 42 and 100 kAIC ratings Factory-cabled connection from test block to line side of tenant main ● ● ● ● ● ● ● ● 100 and 200A units 480 Vac maximum NEMA 3R construction for indoor/outdoor applications Underground or overhead feed Provisions for selfcontained watthour meter Bussed connection from meter socket to test block Tenant main disconnects are available with circuit breakers up to 480 Vac maximum and T-fuse mains, 240 Vac maximum Load wires can exit top or bottom 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-83 5.9 Metering Products Meter Breakers 5 Product Selection 5 Overhead and Underground Combination Units and Individual Units 5 CH127TB Individual Safety Sockets—600V Maximum—No Secondary Feeder Devices Phase, Wire Maximum Interrupting Rating Wire Size Catalog Number OH/UG Single-phase, three-wire 1 #14–2/0 CH114TB 600 OH/UG Three-phase, three-wire 1 #14–2/0 CH115TB 7 600 OH/UG Three-phase, four-wire 1 #14–2/0 CH117TB 200 4 600 OH/UG Single-phase, three-wire 1 #6–250 kcmil CH124TB 200 5 600 OH/UG Three-phase, three-wire 1 #6–250 kcmil CH125TB 200 7 600 OH/UG Three-phase, four-wire 1 #6–250 kcmil CH127TB Ampere Rating No. of Jaws AC Voltage Service 125 4 600 125 5 5 125 5 5 5 5 5 Commercial Safety Sockets with Provision for Main Circuit Breaker 5 Ampere Rating No. of Jaws AC Voltage Service 5 125 4 240 125 7 125 5 5 5 5 5 Phase, Wire Feeder Circuit Breaker Maximum Interrupting Rating Wire Size Catalog Number OH Single-phase, three-wire Provision 2 4 #14–2/0 CH214MTBLB 208/120 OH Three-phase, four-wire Provision 2 4 #14–2/0 CH217MTBLB 4 240 UG Single-phase, three-wire Provision 2 4 #14–2/0 CHU214MTBLB 125 7 208/120 UG Three-phase, four-wire Provision 2 4 #14–2/0 CHU217MTBLB 200 4 120/240 OH Single-phase, three-wire Provision 3 5 #6–250 kcmil CH224MTBLB 3 5 200 7 208/120 OH Three-phase, four-wire Provision #6–250 kcmil CH227MTBLB 200 4 120/240 UG Single-phase, three-wire Provision 3 5 #6–250 kcmil CHU224MTBLB 200 7 208/120 UG Three-phase, four-wire Provision 3 5 #6–250 kcmil CHU227MTBLB Commercial Safety Sockets with Main Circuit Breaker Included 5 Phase, Wire Feeder Circuit Breaker Maximum Interrupting Rating Wire Size Catalog Number OH Three-phase, four-wire EHD3100 14 kA #14–2/0 CH217MTBM515 480/277 UG Three-phase, four-wire EHD3100 14 kA #14–2/0 CHU217MTBMS15 480/277 OH Three-phase, four-wire JD3200 25 kA #6–250 kcmil CH227MTBHMS15 480/277 UG Three-phase, four-wire JD3200 25 kA #6–250 kcmil CHU227MTBHMS15 Ampere Rating No. of Jaws AC Voltage Service 100 7 480/277 5 100 7 5 200 7 200 7 5 5 Notes 1 If being protected by a fuse, the interrupting rating of the unit is limited to the fuse AIC rating. If being protected by a single- or three-phase, 600V breaker, the AIC is 14 kA; by a maximum 400A, single-phase, 240V breaker, the AIC is 18 kA; by a maximum 200A, single- or three-phase, 240V breaker, the AIC is 18 kA; by a maximum 125A, single-phase, 240V breaker, the AIC is 22 kA. 2 Order plug-on Type BR, BRH or BRHH circuit breaker separately. 3 Order Type CC breaker or CCH breaker separately. 4 Type BR = 10 kA; Type BRH = 22 kA; Type BRHH = 42 kA. 5 Type CCV = 10 kA; Type CCVH = 25 kA. 5 5 5 5 5 5 5 5 5 V1-T5-84 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 5.9 Metering Products Meter Breakers Underground Combination Units and Safety Socket Accessories CHU227MTBP 5 Commercial Safety Sockets with T-Fuse Switch 5 Phase, Wire Feeder Circuit Breaker Maximum Interrupting Rating Wire Size 5 OH Single-phase, three-wire 200 kA #14–2/0 CH214MTBP OH Three-phase, four-wire 200 kA #14–2/0 CH217MTBP 5 Ampere Rating No. of Jaws AC Voltage Service 100 4 120/240 100 7 208/120 100 4 120/240 UG Single-phase, three-wire 200 kA #14–2/0 CHU214MTBP 100 7 208/120 UG Three-phase, four-wire 200 kA #14–2/0 CHU217MTBP 200 4 120/240 OH Single-phase, three-wire 200 kA #6–250 kcmil CH224MTBP 200 7 208/120 OH Three-phase, four-wire 200 kA #6–250 kcmil CH227MTBP 200 4 120/240 UG Single-phase, three-wire 200 kA #6–250 kcmil CHU224MTBP 200 7 208/120 UG Three-phase, four-wire 200 kA #6–250 kcmil CHU227MTBP 5 5 5 5 5 Hubs Description Carton Weight Lbs (kg) Catalog Number 5 Hub closure plate 3 (1.4) ARP00002CHB 1.00-inch (25.4 mm) hub 3 (1.4) ARP00003CH1 5 1.25-inch (31.8 mm) hub 3 (1.4) ARP00004CH12 1.50-inch (38.1 mm) hub 3 (1.4) ARP00005CH15 2.00-inch (50.8 mm) hub 3 (1.4) ARP00006CH2 2.50-inch (63.5 mm) hub 3 (1.4) ARP00007CH25 5 5 5 5 Jaws Description Part Number 5th jaw kit CH50371 5 5 Note Order Type CC or CHH breaker separately. 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-85 5.9 5 Metering Products Meter Breakers CH Style Renovation Solutions Contents Description 5 Page Residential Meter Breakers . . . . . . . . . . . . . . . . . Non-EUSERC Combination Service Entrance Devices 100–200A Styles. . . . . . . . . . . . . . . . . . Meets EUSERC Requirements Service Entrance Devices 100–225A . . . . . . . . . . . . . . . . . . . . . . . West Coast All-In-One Design . . . . . . . . . . . . . . . Mechanical Interlock Cover . . . . . . . . . . . . . . . . . . House Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . Commercial Safety Sockets . . . . . . . . . . . . . . . . . CH Style Renovation Solutions Aluminum Meter Breakers . . . . . . . . . . . . . . . . . . 5 5 5 5 5 5 5 5 5 CH Style Renovation Solutions 5 Product Description 5 5 ● ● 5 ● 5 ● ● 5 Ring style meter socket design Provisional main breaker or factory main breaker available Center top feed design Exit bottom or top design 100A, 125A or 200A ratings available 5 Product Selection 5 CH Style Retrofit Solutions 5 Description Catalog Number 100 CH, 22 circuit, provision, center top feed, exit top or bottom, flush, OH/UG CMBE22P100BTFR 125 CH, 22 circuit, provision, center top feed, exit top or bottom, surface, OH/UG CMBE22P125BTSR 5 125 CH, 22 circuit, provision, center top feed, exit top or bottom, flush, OH/UG CMBE22P125BTFR 200 CH, 32/42 circuit, 200A main breaker, center top feed, exit top or bottom, semi-flush, OH/UG CMBE3242B200BTS 5 200 CH, 32/42 circuit, 200A main breaker, center top feed, exit top or bottom, flush, OH/UG CMBE3242B200BTFR 5 Ampere Rating 5 5 5 5 5 5 5 V1-T5-86 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-37 V1-T5-39 V1-T5-48 V1-T5-59 V1-T5-65 V1-T5-75 V1-T5-83 V1-T5-87 Metering Products Meter Breakers 5.9 Contents Description Page Residential Meter Breakers . . . . . . . . . . . . . . . . . . Non-EUSERC Combination Service Entrance Devices 100–200A Styles . . . . . . . . . . . . . . . . . . Meets EUSERC Requirements Service Entrance Devices 100–225A . . . . . . . . . . . . . . . . . . . . . . . West Coast All-In-One Design. . . . . . . . . . . . . . . . Mechanical Interlock Cover . . . . . . . . . . . . . . . . . . House Panels . . . . . . . . . . . . . . . . . . . . . . . . . . . . Commercial Safety Sockets. . . . . . . . . . . . . . . . . . CH Style Renovation Solutions . . . . . . . . . . . . . . . Aluminum Meter Breakers 5 V1-T5-37 5 V1-T5-39 5 V1-T5-48 V1-T5-59 V1-T5-65 V1-T5-75 V1-T5-83 V1-T5-86 5 5 5 5 5 5 5 5 Aluminum Meter Breakers Product Description Features and Benefits Eaton’s Aluminum Meter Breaker enclosure and external cover offers excellent corrosion resistance in the harshest coastal environments. The meter breaker’s light weight and overhead/underground design offers flexibility and ease of installation. ● ● ● Overhead/underground design provides flexibility with wiring options Steel meter guides are standard, which provides a means of easy installation of the utility glass bulb meter into the meter’s jaws Main Lug Only design includes six two-pole breaker locations, which complies with National Electrical Code 225.33 (maximum number of disconnects) ● ● ● ● ● Distribution section accepts BR branch breakers Single-phase, three-wire 120/240 Vac applications Hub closure plate is provided, attached to the top of the device Optional fifth jaw can be applied to 3 o’clock or 9 o’clock meter socket position 10-year warranty ● ● For customer support, contact Eaton’s Technical Resource Center at 1-877-ETN-CARE For additional information or to place an order, contact your local Eaton representative or visit us at www.eaton.com 5 5 5 5 5 5 5 5 5 5 Catalog Number Selection 5 Meter Breakers 5 MB 12 12 L 200 BT S A 5 Material A = Aluminum Meter Breaker Type MB = 1-inch (25.4 mm) BR Type 5 Mounting S = Surface Spacing Number of spaces Poles Maximum number of poles 5 Main L = Lug 5 Breaker Feed BT = Bottom and top 5 Amperes Amperage of unit 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-87 5.10 5 Metering Products Group Metering Systems for Residential and Commercial Application Description 5 Systems for Residential and Commercial Applications Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type CCV 120/240V Tenant Main Circuit Breaker . Type CV 120/240V Tenant Main Circuit Breaker . . Meter Packs—1MP, 1MM and 3MM Main Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . Main Service Modules . . . . . . . . . . . . . . . . . . . . . Surge Metering. . . . . . . . . . . . . . . . . . . . . . . . . . . Residential Meter Stacks . . . . . . . . . . . . . . . . . . . 1MP, 1MM and 3MM Main Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . Phase Balanced Stack. . . . . . . . . . . . . . . . . . . . . . Commercial Meter Stack Modules . . . . . . . . . . . . 35MM, 37MM, 35SS and 37SS Main Tenant Circuit Breakers . . . . . . . . . . . . . . . 5 5 5 5 5 5 5 5 5 Systems for Residential and Commercial Applications 5 Product Description Application Description Group metering is a service entrance product line that consists of a main device and multiple meter sockets in one enclosure or several connected enclosures. Group metering allows the customer to install a multiple tenant-metering device in one location while providing a space and installation cost savings. Eaton’s Electrical Sector offers two group metering designs—Meter Packs and Gangable Metering. Meter Packs, also called All-in-Ones, consist of main lugs and up to six meter sockets in one enclosure. Meter Packs are supplied as one complete unit and the user cannot “add” additional meter sockets to the unit in the future. The most common application for Meter Packs is garden apartments, small condominiums and townhouses where six or less units are metered through one centrally located Meter Pack. 5 5 5 5 5 5 Contents 5 5 5 5 5 5 5 Gangable Metering (Main Service Modules and Meter Stacks) The second type of group metering is Gangable Metering, which consists of a Main Service Module used in conjunction with a Meter Stack to make a custom metering lineup. The Main Service Module can be main lug, main circuit breaker, main fusible switch or bolted pressure switch. The Meter Stack is offered with various meter sockets and bus ratings. This type of custom lineup allows the owner to add/remove meter sockets and main devices to meet future need. Gangable Metering is often used in large condominiums, strip malls and light commercial applications where more than six units are metered, or there will be a future need to add more units. 5 5 5 5 5 V1-T5-88 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Page V1-T5-90 V1-T5-95 V1-T5-96 V1-T5-98 V1-T5-101 V1-T5-115 V1-T5-116 V1-T5-125 V1-T5-126 V1-T5-127 V1-T5-134 5.10 Metering Products Group Metering Features, Benefits and Functions Clip-Tight™ Socket 5 Field Phase Balancing Lever Bypass Main Tenant Breaker Cover 5 5 5 5 5 5 Clip-Tight Socket Field Phase Balancing Lever Bypass Eaton’s series of 1MP, 1MM, 3MM metering devices incorporate the only socket base in the industry without fasteners. This component uses jaws on both sides of a thermoplastic polyester glass fiber reinforced (PBT) base, eliminating the need for self-tapping screw connections to vertical busbars. Due to popular incoming three-phase voltage systems and single-phase outgoing loads, installers have the option to field phase balance on the individual stack (A-B, B-C, A-C). This feature eliminates the chance of installing an incorrectly phased device due to its versatility. Due to commercial requirements, Eaton offers a lever bypass (as standard) on all 35MM and 37MM devices. Each socket base consists of a lever bypass, which also releases the jaws (when lever is engaged in bypass position), enabling utility company mechanics to easily remove and/or insert utility meter. One-Piece Vertical Busbar Horn and Manual Bypass Test Bypass Disconnects 5 5 5 Main Tenant Breaker Cover Each tenant circuit breaker is protected by a lockable raintight cover that secures the breaker against unauthorized operation. The tenant breaker cover is a high impact plastic to resist wear, rusting and corrosion. 5 5 5 5 5 Mounting Features 5 5 5 5 5 Horn and Manual Bypass One-Piece Vertical Busbar Eaton’s series of 1MP, 1MM, 3MM meter stacks embody a one-piece busbar construction to each socket, as well as a one-piece cross bus to each tenant main. Because the Eaton design uses the Clip-Tight meter socket and does not have busbar joints, the chance of hot spots occurring is virtually eliminated. With an increasing demand for uninterrupted power, Eaton’s series of 1MP, 1MM and 3MM meter sockets offer horn (ringless style) and manual (ring style) fieldinstallable bypass accessories. These accessories provide uninterrupted tenant service if a meter is pulled for inspection or replacement. Mounting Features A standard mounting rail and factory-installed swing away feet speed up and simplify installation. Test Bypass Disconnects Eaton also provides commercial meter stacks with EUSERC required testbypass disconnects (35SS and 37SS). This bypass is used in the same applications as the lever bypass and it is required by EUSERC utilities. Standards and Certifications ● UL listed 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-89 5.10 5 Metering Products Group Metering Contents Meter Pack Description 5 Systems for Residential and Commercial Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . Meter Packs Type CCV 120/240V Tenant Main Circuit Breaker . Type CV 120/240V Tenant Main Circuit Breaker . . Meter Packs—1MP, 1MM and 3MM Main Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . Main Service Modules . . . . . . . . . . . . . . . . . . . . . Surge Metering. . . . . . . . . . . . . . . . . . . . . . . . . . . Residential Meter Stacks . . . . . . . . . . . . . . . . . . . 1MP, 1MM and 3MM Main Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . Phase Balanced Stack. . . . . . . . . . . . . . . . . . . . . . Commercial Meter Stack Modules . . . . . . . . . . . . 35MM, 37MM, 35SS and 37SS Main Tenant Circuit Breakers . . . . . . . . . . . . . . . 5 5 5 5 5 5 5 5 5 Meter Packs 5 Product Overview 5 ● 5 5 ● 5 5 ● 5 5 5 5 5 5 5 ● ● ● Eaton’s 1MP units are self-contained (main terminal box included) for installations requiring up to six meter socket positions in a single enclosure Units are not gangable with any other metering device Approved by major power companies, UL listed, suitable as service equipment and meet the service and electrical requirements of EUSERC and CECHA Series rating up to 100 kAIC All ringless cover devices include fifth jaw as standard Ring type devices do not include fifth jaw as standard. Order 1MM5JK if needed ● ● ● ● ● ● ● ● Bondable neutral 120/240 Vac, single-phase three-wire metering device Up to 600A maximum horizontal bus rating Incoming lugs not included (phase A, phase B and neutral) Indoor/outdoor construction Provision for two-pole breaker (plug-on type for 125A sockets and bolt-on type for 200A sockets)— circuit breakers not included Underground incoming feed Aluminum or copper bus 5 5 5 5 5 5 V1-T5-90 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Page V1-T5-88 V1-T5-95 V1-T5-96 V1-T5-98 V1-T5-101 V1-T5-115 V1-T5-116 V1-T5-125 V1-T5-126 V1-T5-127 V1-T5-134 Metering Products Group Metering 5.10 Catalog Number Selection 5 1 M P 4 12 4 R C Single-Phase Type of Metering MP = Meter pack Number of Meters 2, 3, 4, 5 or 6 Blank = Accessory Ampere Rating 12 = 125A 20 = 200A Blank = Accessory 5 5 Bus Material C = Copper bus Blank = Aluminum bus 5 5 Security or Accessory Code R= Ring RRL = Ringless RRLB = Ringless with horn bypass LK = Lug kit (accessory) SC = Crimp lug landing pad kit (accessory) 5 5 5 Bus Ampere Rating 2 = 200A 4 = 400A 6 = 600A Blank = Accessory 5 5 When Ordering: 1. Determine catalog number of the basic device. 5 2. Include Lug Kit for incoming section. See Page V1-T5-94. 3. Find quantity and catalog numbers for tenant circuit breakers. (Order one breaker per socket.) See Page V1-T5-94. 5 4. Select required accessories. See Page V1-T5-136. 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-91 5.10 Metering Products Group Metering 5 Product Selection 5 Meter Packs 5 Aluminum Bus—Main Lugs Not Included—See Page V1-T5-94 5 Socket Ampere Rating 5 5 Number of Meter Sockets Bus Ampere Rating Main Tenant Breaker Type (See Page V1-T5-94) Catalog Number Semi-Flush Flange Kit Catalog Number Ring Style Meter Socket Covers 1 125 2 24 200 125 2 3 400 2 Plug-on type BR2_ BRH2_ BRHH2_ 1MP2122R 58 1MPSFK1 1MP3124R 6 1MPSFK2 6 1MPSFK2 5 125 4 400 125 2 54 600 1MP5126R 6 1MPSFK3 5 125 2 64 600 1MP6126R 6 1MPSFK3 5 200 3 2 400 1MP2204R 6 1MPSFK4 200 3 3 600 1MP3206R 6 1MPSFK5 5 200 3 4 600 1MP4206R 6 1MPSFK5 200 3 5 600 1MP5206R 6 1MPSFK6 5 200 3 6 600 1MP6206R 6 1MPSFK6 1MP2122RRL 58 1MPSFK1 1MP3124RRL 6 1MPSFK2 1MP4124RRL 6 1MPSFK2 Bolt-on type CCV2_X CCVH2_X CVS2_XMM CV2_XMM CVH2_XMM 1MP4124R Ringless Style Meter Socket Covers 7 5 125 2 200 5 125 3 400 125 4 400 5 125 5 600 1MP5126RRL 6 1MPSFK3 125 6 600 1MP6126RRL 6 1MPSFK3 5 200 2 400 1MP2204RRL 6 1MPSFK4 200 3 600 1MP3206RRL 6 1MPSFK5 6 1MPSFK5 1MP5206RRL 6 1MPSFK6 1MP6206RRL 6 1MPSFK6 1MP2122RRLB 58 1MPSFK1 1MP3124RRLB 69 1MPSFK2 1MP4124RRLB 69 1MPSFK2 5 200 4 600 5 200 5 600 200 6 600 5 Ringless Style Covers with Horn Bypass 7 Plug-on type BR2_ BRH2_ BRHH2_ Bolt-on type CCV2_X CCVH2_X CVS2_XMM CV2_XMM CVH2_XMM 125 2 200 5 125 3 400 5 125 4 400 125 5 600 1MP5126RRLB 69 1MPSFK3 69 1MPSFK3 1MP2204RRLB 69 1MPSFK4 1MP3206RRLB 69 1MPSFK5 1MP4206RRLB 69 1MPSFK5 1MP5206RRLB 69 1MPSFK6 1MP6206RRLB 69 1MPSFK6 5 125 6 600 200 2 400 5 200 3 600 200 4 600 200 5 600 200 6 600 5 5 5 5 5 5 5 Plug-on type BR2_ BRH2_ BRHH2_ 1MP4206RRL 1MP6126RRLB Bolt-on type CCV2_X CCVH2_X CVS2_XMM CV2_XMM CVH2_XMM Notes 1 Ring Style Meter Packs do not come with fifth jaw. Order 1MM5JK if needed. 2 To change in field from ring to ringless—order 1MMRC125. 3 To change in field from ring to ringless—order 1MMRC200. 4 To change from ring to ringless covers, the top socket only in 2, 5 and 6 socket designs—order 1MMRC125T. Top socket only. 5 Main lugs included. #6–300 kcmil. (Optional lugs are not available.) 6 For overhead use, order DS_H2 type hub. 7 Fifth jaw factory installed at 9 o’clock position. 8 For overhead use, order DS type hub. 9 To order with raceway provision in bottom endwall, add “T” suffix to the catalog number. Trough accessory catalog number is 1008934CH. See Page V1-T5-94 for Main Lug Kit selection and Wire Sizes. 5 V1-T5-92 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Group Metering 5.10 Copper Bus—Main Lugs Not Included—See Page V1-T5-94 Socket Ampere Rating Number of Meter Sockets Bus Ampere Rating Main Tenant Breaker Type (See Page V1-T5-94) 5 Semi-Flush Flange Kit Catalog Number Catalog Number 5 Ring Style Meter Socket Covers 1 125 2 24 1MP2122RC 6 1MPSFK1 7 1MPSFK2 1MP4124RC 7 1MPSFK2 600 1MP5126RC 7 1MPSFK3 600 1MP6126RC 7 1MPSFK3 200 2 3 400 125 2 4 400 125 2 54 125 2 64 200 3 2 400 200 3 3 600 200 3 4 600 125 3 5 600 200 3 6 600 200 Plug-on type BR2_ BRH2_ BRHH2_ Bolt-on type CCV2_X CCVH2_X CVS2_XMM CV2_XMM CVH2_XMM 1MP3124RC 1MP2204RC 7 1MPSFK4 1MP3206RC 7 1MPSFK5 1MP4206RC 7 1MPSFK5 7 1MPSFK6 1MP6206RC 7 1MPSFK6 1MP2122RRLC 7 1MPSFK1 1MP3124RRLC 7 1MPSFK2 1MP4124RRLC 7 1MPSFK2 1MP5126RRLC 7 1MPSFK3 1MP6126RRLC 7 1MPSFK3 1MP2204RRLC 7 1MPSFK4 1MP5206RC 5 5 5 5 5 5 5 Ringless Style Meter Socket Covers 5 125 2 200 125 3 400 125 4 400 125 5 600 125 6 600 200 2 400 200 3 600 200 4 600 200 5 600 200 6 Plug-on type BR2_ BRH2_ BRHH2_ Bolt-on type CCV2_X CCVH2_X CVS2_XMM CV2_XMM CVH2_XMM 600 5 5 5 5 1MP3206RRLC 7 1MPSFK5 1MP4206RRLC 7 1MPSFK5 1MP5206RRLC 7 1MPSFK6 7 1MPSFK6 5 7 1MPSFK1 1MP3124RRLBC 7 1MPSFK2 5 1MP4124RRLBC 7 1MPSFK2 1MP5126RRLBC 7 1MPSFK3 1MP6126RRLBC 7 1MPSFK3 1MP2204RRLBC 7 1MPSFK4 1MP3206RRLBC 7 1MPSFK5 1MP4206RRLBC 7 1MPSFK5 1MP5206RRLBC 7 1MPSFK6 1MP6206RRLBC 7 1MPSFK6 1MP6206RRLC 5 Ringless Style Covers with Horn Bypass 5 125 2 200 125 3 400 125 4 400 125 5 600 125 6 600 200 2 400 200 3 600 200 4 600 200 5 600 200 6 600 Plug-on type BR2_ BRH2_ BRHH2_ Bolt-on type CCV2_X CCVH2_X CVS2_XMM CV2_XMM CVH2_XMM 1MP2122RRLBC 5 5 5 5 5 5 Notes 1 Ring Style Meter Packs do not come with fifth jaw. Order 1MM5JK if needed. 2 To change in field from ring to ringless—order 1MMRC125. 3 To change in field from ring to ringless—order 1MMRC200. 4 To change in field from ring to ringless covers, the top socket only in 5 to 6 socket design—order 1MMRC125T. Top socket only—other sockets see 2. 5 Fifth jaw factory installed at 9 o’clock position. 6 For overhead use, order DS_H2 type hub. 7 For overhead use, order DS_MH type hub. 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-93 5.10 5 1MPLK3 Metering Products Group Metering Main Lug Selection—Field-Installed Lugs for 400 or 600A Main Bus 5 Line Lug and Wire Sizes Order Separately and Field Install Line Lug Kit Catalog Number Order Three Kits (For Two Lines and Neutral) 5 (1) #6–600 kcmil or (2) 2/0–250 kcmil 1MPLK1 (2) 250–500 kcmil 1MPLK3 5 (3) #4–300 kcmil 1MPLK4 1 (1) 750 kcmil 1MPLK2 2 5 Crimp lug landing pad 250–750 kcmil 1MPSC1 1 5 Wire Sizes—Neutral and Ground Lugs 5 Description Wire Size, Al/Cu Catalog Number 5 Neutral—125A meter pack #6–2/0 — Neutral—200A meter pack #1/0–300 kcmil — 5 Equipment ground bar—125A meter pack #14–#2 — Equipment ground bar—200A meter pack #14–2/0 — 5 Optional ground bar #6–2/0 1MMGBK 5 Notes 1 This kit comes with three pads for two lines and neutral. Each pad will accept one or two crimp lugs. Cannot be used on 1MP2122R, RL, RC and RLB EUSERC underground termination. 2 This lug is not UL listed. 5 Each stack includes a neutral and ground bar. If an extra ground bar is needed, order 1MMGBK. 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 V1-T5-94 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Group Metering 5.10 Contents Type CCV Tenant Main Circuit Breaker Description Page Systems for Residential and Commercial Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type CCV 120/240V Tenant Main Circuit Breaker Type CV 120/240V Tenant Main Circuit Breaker . . Meter Packs—1MP, 1MM and 3MM Main Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . . Main Service Modules . . . . . . . . . . . . . . . . . . . . . Surge Metering . . . . . . . . . . . . . . . . . . . . . . . . . . . Residential Meter Stacks. . . . . . . . . . . . . . . . . . . . 1MP, 1MM and 3MM Main Tenant Circuit Breakers. . . . . . . . . . . . . . . . . . . . . . . . . . Phase Balanced Stack . . . . . . . . . . . . . . . . . . . . . . Commercial Meter Stack Modules . . . . . . . . . . . . 35MM, 37MM, 35SS and 37SS Main Tenant Circuit Breakers . . . . . . . . . . . . . . . V1-T5-88 V1-T5-90 V1-T5-96 V1-T5-98 V1-T5-101 V1-T5-115 V1-T5-116 Features Eaton offers Type CCV (10 and 22 kAIC) and Type CV (42, 65 and 100 kAIC) family of circuit breakers as the primary tenant main breakers used in most group metering applications. ● ● Product Description Eaton’s residential products Type CCV circuit breaker is available in two-pole configurations from 100A to 225A in 10 and 22 kAIC ratings. ● 5 5 5 5 5 5 V1-T5-134 5 5 5 Standards and Certifications Ratings—120/240 Vac, two-pole, through 225 continuous amperes, calibrated at 40°C Tripping characteristics— thermal-magnetic trip, calibrated and sealed after assembly. Indirectly heated thermal tripping bimetal elements Interrupting capacity at 120/240 Vac. Type CCV— 10 kAIC rms symmetrical. Type CCVH—25 kAIC rms symmetrical 5 V1-T5-125 V1-T5-126 V1-T5-127 Type CCV 120/240V Tenant Main Circuit Breaker Product Overview 5 ● ● ● Handles—trip-free with ON-TRIPPED-OFF positions. Reset past OFF is required to latch breaker contacts after tripping Terminals—standard lugs (wire connectors) suitable for copper or aluminum wire Backward compatibility— Type CCV and CCVH retains same profile and footprint as the CC and CCH breaker, allowing use in the same applications ● Complies with UL Standard 489. Breakers are listed under UL File #E7819 5 5 5 5 5 5 5 5 5 Product Selection 5 Type CCV 120/240V Tenant Main Circuit Breaker 5 Two-Pole Breaker Ampere Rating Wire Size Range, Al/Cu 10 kAIC 25 kAIC 100 #2–300 kcmil CCV2100X CCVH2100X 125 CCV2125X CCVH2125X 150 CCV2150X CCVH2150X 175 CCV2175X CCVH2175X 200 CCV2200X CCVH2200X 225 CCV2225X CCVH2225X 5 5 5 5 5 Modification Codes ● X—load side terminals only 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-95 5.10 5 Metering Products Group Metering Contents Type CV Tenant Main Circuit Breaker Description 5 Systems for Residential and Commercial Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type CCV 120/240V Tenant Main Circuit Breaker . Type CV 120/240V Tenant Main Circuit Breaker . . Meter Packs—1MP, 1MM and 3MM Main Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . Main Service Modules . . . . . . . . . . . . . . . . . . . . . Surge Metering. . . . . . . . . . . . . . . . . . . . . . . . . . . Residential Meter Stacks . . . . . . . . . . . . . . . . . . . 1MP, 1MM and 3MM Main Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . Phase Balanced Stack. . . . . . . . . . . . . . . . . . . . . . Commercial Meter Stack Modules . . . . . . . . . . . . 35MM, 37MM, 35SS and 37SS Main Tenant Circuit Breakers . . . . . . . . . . . . . . . 5 5 5 5 5 5 5 5 5 Type CV 120/240V Tenant Main Circuit Breaker 5 Product Overview Features Eaton offers Type CCV (10 and 22 kAIC) and Type CV (42, 65 and 100 kAIC) family of circuit breakers as the primary tenant main breakers used in most group metering applications. ● 5 5 5 5 5 5 5 ● Product Description Eaton’s residential products Type CV molded-case circuit breaker is available in twoand three-pole configurations from 60A to 225A in 42, 65 and 100 kAIC ratings. ● 5 5 5 ● 5 5 ● 5 5 Ratings—120/240 Vac, two- and three-pole, through 225 continuous amperes, calibrated at 40°C Tripping characteristics— thermal-magnetic trip, calibrated and sealed after assembly. Indirectly heated thermal tripping bimetal elements; includes pushto-test button for routine preventive maintenance Interrupting capacity at 120/240 Vac ● Type CVS—42,000A rms symmetrical ● Type CV—65,000A rms symmetrical ● Type CVH—100,000A rms symmetrical Handles—trip-free with ON-TRIPPED-OFF positions. Reset past OFF is required to latch breaker contacts after tripping Terminals—standard lugs (wire connectors) suitable for copper or aluminum wire Standards and Certifications ● Complies with UL Standard 489. Breakers are listed under UL File #E7819 5 5 5 5 V1-T5-96 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Page V1-T5-88 V1-T5-90 V1-T5-95 V1-T5-96 V1-T5-98 V1-T5-101 V1-T5-115 V1-T5-116 V1-T5-125 V1-T5-126 V1-T5-127 V1-T5-134 5.10 Metering Products Group Metering Product Selection Type CV Two-Pole Tenant Main Circuit Breakers Main Tenant Number Circuit Breaker of Poles Ampere Rating Wire Size 42 kAIC Range, Catalog Al/Cu Number 2 #6–4/0 60 5 Type CV Three-Pole Tenant Main Circuit Breakers 65 kAIC 100 kAIC Catalog Number Catalog Number CVS2060XMM CV2060XMM CVH2060XMM 5 Main Tenant Number Circuit Breaker of Poles Ampere Rating Wire Size 42 kAIC Range, Catalog Al/Cu Number 65 kAIC 100 kAIC Catalog Number Catalog Number 5 3 #6–4/0 CVS3060X CV3060X CVH3060X 5 60 70 CVS2070XMM CV2070XMM CVH2070XMM 70 CVS3070X CV3070X CVH3070X 80 CVS2080XMM CV2080XMM CVH2080XMM 80 CVS3080X CV3080X CVH3080X 90 CVS2090XMM CV2090XMM CVH2090XMM 90 CVS3090X CV3090X CVH3090X 100 CVS2100XMM CV2100XMM CVH2100XMM 100 CVS3100X CV3100X CVH3100X 125 CVS2125XMM CV2125XMM CVH2125XMM 125 CVS3125X CV3125X CVH3125X 150 CVS2150XMM CV2150XMM CVH2150XMM 150 CVS3150X CV3150X CVH3150X 175 CVS2175XMM CV2175XMM CVH2175XMM 175 CVS3175X CV3175X CVH3175X 200 CVS2200XMM CV2200XMM CVH2200XMM 200 CVS3200X CV3200X CVH3200X 225 CVS2225XMM CV2225XMM CVH2225XMM 225 CVS3225X CV3225X CVH3225X 5 5 5 5 5 Accessories 5 Field Installable Description Catalog Number Two-pole 300 kcmil with terminal shield 2TA225CVK Three-pole 300 kcmil with terminal shield 3TA225CVK Replacement mounting hardware kit for 200A 1MP, 1MM and 3MM units 1MMCBK 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-97 5.10 5 Metering Products Group Metering Contents Main Tenant Circuit Breakers Description 5 5 5 5 5 5 5 5 5 5 Meter Packs—1MP, 1MM and 3MM Main Tenant Circuit Breakers 5 Product Description 5 5 5 Page Systems for Residential and Commercial Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type CCV 120/240V Tenant Main Circuit Breaker . Type CV 120/240V Tenant Main Circuit Breaker . . Meter Packs—1MP, 1MM and 3MM Main Tenant Circuit Breakers Main Service Modules . . . . . . . . . . . . . . . . . . . . . Surge Metering. . . . . . . . . . . . . . . . . . . . . . . . . . . Residential Meter Stacks . . . . . . . . . . . . . . . . . . . 1MP, 1MM and 3MM Main Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . Phase Balanced Stack. . . . . . . . . . . . . . . . . . . . . . Commercial Meter Stack Modules . . . . . . . . . . . . 35MM, 37MM, 35SS and 37SS Main Tenant Circuit Breakers . . . . . . . . . . . . . . . V1-T5-88 V1-T5-90 V1-T5-95 V1-T5-96 V1-T5-101 V1-T5-115 V1-T5-116 V1-T5-125 V1-T5-126 V1-T5-127 V1-T5-134 Specific main tenant circuit breakers that are to be used in meter packs (1MP), residential meter stacks (1MM) and three-phase in single-phase out meter stacks (3MM). 5 5 Product Selection 5 Main Tenant Circuit Breaker Ampere Rating 10 kAIC 22 kAIC 25 kAIC 65 kAIC 100 kAIC Number of Poles Catalog Number 1 Catalog Number Catalog Catalog Number 1234 Number 234 Catalog Number 234 Catalog Number 234 2 60 BR260 BRH260 — BRHH260 — — 2 70 BR270 BRH270 — BRHH270 — — 2 80 BR280 BRH280 — BRHH280 — — 2 90 BR290 BRH290 — BRHH290 — — 2 100 BR2100 BRH2100 — BRHH2100 — — 2 110 BR2110 BRH2110 — BRHH2110 — — 2 125 BR2125 BRH2125 — BRHH2125 — — 2 60 — — CVS2060XMM CVS2060XMM CV2060XMM CVH2060XMM 2 70 — — CVS2070XMM CVS2070XMM CV2070XMM CVH2070XMM 2 80 — — CVS2080XMM CVS2080XMM CV2080XMM CVH2080XMM 2 90 — — CVS2090XMM CVS2090XMM CV2090XMM CVH2090XMM 5 2 100 CCV2100X — CCVH2100X CVS2100XMM CV2100XMM CVH2100XMM 2 125 CCV2125X — CCVH2125X CVS2125XMM CV2125XMM CVH2125XMM 5 2 150 CCV2150X — CCVH2150X CVS2150XMM CV2150XMM CVH2150XMM 2 175 CCV2175X — CCVH2175X CVS2175XMM CV2175XMM CVH2175XMM 5 2 200 CCV2200X — CCVH2200X CVS2200XMM CV2200XMM CVH2200XMM 5 5 5 Description Plug-On Type Plug-on type circuit breakers used with 1MP, 1MM, and 3MM 125A modular metering stacks 5 5 5 5 5 5 42 kAIC Bolt-On Type Bolt-on type circuit breakers used with 1MP, 1MM, and 3MM 200A modular metering stacks Notes 1 #2–300 kcmil wire size range for CCV and CCVH tenant main circuit breakers. 2 “MM” suffix indicates mounting hardware kit is included as standard with tenant main breaker. 3 1MMCBK replacement mounting hardware kit. One kit is needed per breaker. Mounting hardware kit ships standard with breaker “MM” suffix offering. 4 #6–4/0 kcmil wire size range for CVS, CV and CVH tenant main circuit breakers. If #2–300 kcmil is needed, order 2TA225CVK. One kit needed per breaker. V1-T5-98 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Group Metering 5.10 Dimensions and Knockouts 5 Approximate Dimensions in Inches (mm) 5 1MP, 125 Ampere Meter Packs—Aluminum and Copper Bus 24.260 5 5.610 27.000 4.565 .450 5.610 5.125 11.880 9.380 5.000 5 5 3.000 3.000 36.130 2.560 5 8.000 3.00 (76.2) "Z" = C L of 1/2" Ring "Y" = C L of 1-1/2" Ring "X" = C L of 1-1/2" Ring "W" = C L of 4" Ring 5 4.690 7.015 "W" "X" "Y" "Z" 5.125 24.08 (611.6) 5 4.555 "W" .450 5 5, 6 Meter Device .695 3.615 4.690 7.005 "X" "Y" 5 Concentric Knockouts 1/2" Knockout Concentric Knockouts 1", 1-1/4", 1-1/2", Knockout Concentric Knockouts 2-1/2", 3", 3-1/2", 4 " Knockout Concentric Knockouts 1/2" Knockout 41.600 9.000 (1) Knockout for 1-1/2, 2, 2-1/2 Conduit 3, 4 Meter Device Concentric Knockouts 1", 1-1/4", 1-1/2", Knockout Concentric Knockouts 2-1/2", 3", 3-1/2", 4 " Knockout 14.460 5 3.625 (3) Knockout for 1, 1-1/4, 1-1/2 Conduit 6.560 7.015 5 12.550 9.000 48.290 12.552 9.000 9.000 9.000 34.250 To CL of Wall Mtg. Screw 21.699 CL Meter ToCL Rail Mtg. Screw 2.025 3.140 "Z" 5 36.280 Mtn. for 2, 2-1/2, 3" C-H Conduit Hubs 5 6.380 5.900 .060 2.250 5 1", 1-1/4", 1-1/2" Knockouts (6 Required) 1/2" Knockout 2.625 2.313 5 23.750 1-1/2", 2", 2-1/2", 3" Knockouts 34.180 5 .875 5 57 Mtg Holes 4 Places 1, 1-1/4, 1-1/2" KO 6 Places 1.500 1.438 4.375 4.389 2.313 5 2.750 1.880 1.806 5 1.440 1.063 .438 5 2.750 2.880 4.000 3.063 Dia. Hub Opening 5 2.277 5 3.688 3.250 5 2.563 6.500 Bottom Endwall Knockouts for Units with "T" Suffix 3, 4 Meter Device 3.063 5 Top View 5 5 3.250 2.563 6.500 5 Bottom Endwall Knockouts for Units with "T" Suffix 5, 6 Meter Device 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-99 5.10 Approximate Dimensions in Inches (mm) 1MP, 200 Ampere Meter Packs—Aluminum and Copper Bus 25.480 25.480 5 2.015 5 5 5 2 Meter Device 5 5 3.125 7.015 5 12.125 52.415 12.125 5 Typ. 3.000 5.125 24.080 "Z" = C L of 1/2" Ring "Y" = C L of 1-1/2" Ring C "X" = L of 1-1/2" Ring "W" = C L of 4" Ring 5, 6 Meter Device Concentric Knockouts 2-1/2", 3", 3-1/2", 4 " Knockout Concentric Knockouts 1", 1-1/4", 1-1/2", 2" Knockout Concentric Knockouts 1/2" Knockout 4.565 27.000 .695 3.625 "W" "X" "Y" "Z" .450 5.610 3.000 8.000 3.000 7.015 4.690 6.555 5 5 5.610 18.425 5 5 .450 2, 3 & 4 Meter Endwall 5 5 "W" "X" "Y" "Z" 3.250 2.563 6.500 38.635 Bottom Endwall Knockouts for Units with "T" Suffix 2, 3, 4 Meter Device 5 5 5 3.250 5 2.563 6.500 Bottom Endwall Knockouts for Units with "T" Suffix 5, 6 Meter Device 5 5 V1-T5-100 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 7.005 5 3.615 4.690 5 3, 4 Meter Device Concentric Knockouts 1/2" Knockout Concentric Knockouts 1", 1-1/4", 1-1/2", 2" Knockout Concentric Knockouts 4.555 15.000 2-1/2", 3", 3-1/2", 4 " Knockout 2.015 5 5 (4) Knock Out For 1", 1-1/4", 1-1/2", 2" Conduit 38.755 5 64.535 12.125 12.125 18.400 5 18.425 5 15.826 CL Meter To CL Rail Mtg. Screw 12.155 5 12.125 2.015 34.250 To CL of Wall Mtg. Screw 5 Group Metering 42.685 5 Metering Products Metering Products Group Metering 5.10 Contents Description Page Systems for Residential and Commercial Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type CCV 120/240V Tenant Main Circuit Breaker . Type CV 120/240V Tenant Main Circuit Breaker . . Meter Packs—1MP, 1MM and 3MM Main Tenant Circuit Breakers. . . . . . . . . . . . . . . . . . . . Main Service Modules Surge Metering . . . . . . . . . . . . . . . . . . . . . . . . . . . Residential Meter Stacks . . . . . . . . . . . . . . . . . . . 1MP, 1MM and 3MM Main Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . Phase Balanced Stack . . . . . . . . . . . . . . . . . . . . . . Commercial Meter Stack Modules . . . . . . . . . . . . 35MM, 37MM, 35SS and 37SS Main Tenant Circuit Breakers . . . . . . . . . . . . . . . V1-T5-88 V1-T5-90 V1-T5-95 V1-T5-96 V1-T5-98 V1-T5-115 V1-T5-116 ● ● ● ● ● ● Main terminal box Main circuit breaker Main bolted pressure switch Main fusible switch Main fusible switch with pull box Underground pull box Application Description Main Circuit Breakers with Busway Connections The Service Entrance Product Team announces the availability of both main fusible switch and main circuit breaker group metering mains with busway connections. This offering provides us with the ability to offer multiple tenant metering in high rise apartment buildings where riser busway is used. 5 5 5 5 5 5 V1-T5-125 V1-T5-126 V1-T5-127 5 V1-T5-134 5 5 5 Main Service Modules Product Description 5 5 Features, Benefits and Functions Eaton’s Main Service Module ● Offering: main terminal/lug compartment, main circuit breaker, main fusible switch, main bolted pressure switch, main fusible switch with pull box (meets EUSERC electrical requirements), underground pull box termination compartment without cross bus (meets EUSERC electrical requirements) ● Mechanically and electrically built for use with 1MM, 3MM, 35MM, 37MM, 35SS and 37SS modular metering stacks ● For integrated system short-circuit ratings with main devices, see series ratings on Page V1-T5-142 ● All main service modules include both left and right horizontal bus closure plates ● Two-pole devices are applied to single-phase, three-wire, 120/240V or 208Y/120V systems, threepole devices to 208Y/240V or 120/240V delta systems ● ● ● ● Single-phase mains couple to any modular metering stack (1MM, 3MM, 35MM, 37MM, 35SS and 37SS) Three-phase mains require three-phase bussed stacks. These modular metering stacks are 3MM, 35MM, 37MM, 35SS and 37SS If the ampere rating of the main service module is greater than the horizontal bus rating of the meter stack (residential or commercial), the main service module must be center fed. Examples: 1200A Main Circuit Breaker (1MCB1200R) with an 800A residential stack (1MM512R). 1600A Main Terminal Box (3MTB1600R) with a 1200A residential stack (3MM212R12) Most main service modules are available with aluminum or copper bus Main Circuit Breakers with Busway Connections ● Three-phase, 400–200A main circuit breakers ● Three-phase, 400–800A main fusible switches ● Simple bridge joint connection ● Variety of options: ● Right or left mounting ● Internal ground or housing ground ● The MFS/MCB and busway connector are supplied completely assembled 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-101 5.10 5 Metering Products Group Metering Catalog Number Selection 5 3 MTB 400 R 5 Phase 1 = Single-phase 3 = Three-phase 5 5 5 5 5 Accessories and Additional Options BLK= Box lug kit (accessory) CLK= Compression lug (accessory) B = Bottom feed T = Top feed UG= Pull box Blank= No options Enclosure R = NEMA 3R Ampere Rating 400A 600A 800A 1000A 1200A 1400A 1600A 2000A 5 5 5 Bus Material C = Copper bus Blank= Aluminum bus Type of Metering BTB = Main terminal box MCB = Main circuit breaker BPS = Bolted pressure switch MFS = Main fusible switch UGPB = Underground pull box MTBE = Main terminal box with utility pull box MCBE = Main circuit breaker with utility pull box 5 5 C When Ordering: 1. Determine catalog number of Main Service Module. 5 2. Determine catalog number of Meter Stack (Residential or Commercial). 5 3. Find quantity and catalog numbers for tenant circuit breakers (found on Page V1-T5-125 or V1-T5-135). Order one breaker per socket. 5 4. If any accessories are needed, order from Pages V1-T5-136 and V1-T5-137. 5 5 5 5 5 5 5 5 5 5 5 5 5 5 V1-T5-102 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Group Metering 5.10 Product Selection 5 Main Terminal Box ● Phase and neutral lugs are included ● Top or bottom feed: ● For top feed, use Myer type hub Main Terminal Box ● ● 5 Indoor or outdoor Terminal box UL listed short-circuit rating is the least AIC rating of any installed main tenant breaker—to a maximum of 100,000 rms symmetrical amperes 5 5 5 5 Main Terminal Box System Voltage Ampere Rating Line Side Lug and Wire Sizes—Included 120/208 Vac Three-Phase, Four-Wire Catalog Number Catalog Number 5 Use three-phase 3MTB400R 5 Aluminum Bus (Standard Offering) (1) #6–600 or (2) 1/0–250 kcmil 2 400 3 600 (2) 250–500 kcmil 800 (4) 250–500 kcmil 45 1200 1 (4) 250–500 kcmil 56 5 120/240 Vac Single-Phase, Three-Wire Use three-phase 3MTB600R 1MTB800R 3MTB800R 1MTB1200R 3MTB1200R 5 5 5 Aluminum Bus (EUSERC) 400 Crimp lug landing pads (no lugs included) 1MTBE400R 7 3MTBE400R 7 800 Crimp lug landing pads (no lugs included) 1MTBE800R 7 3MTBE800R 7 5 5 Copper Bus (Premium Offering) kcmil 2 400 (1) #6–600 or (2) 1/0–250 Use three-phase 3MTB400RC 600 (2) 250–500 kcmil 3 Use three-phase 3MTB600RC (4) 250–500 kcmil 45 1MTB800RC 3MTB800RC (4) 250–500 kcmil 56 1MTB1200RC 3MTB1200RC (6) 500 kcmil 8 1MTB1600RC 3MTB1600RC 800 1200 1 1600 1 Main Terminal Box Riser Panel Eaton’s Main Terminal Box Riser Panel is a main terminal box with offset lugs on each phase to allow riser cables to pass through the main service module. 5 5 5 5 These panels are used in the construction of assisted living homes, dormitories, public housing complexes and apartments. 5 5 5 Main Terminal Box Riser Panel System Voltage Ampere Rating Line and Load Side Lug and Wire Sizes Included 120/240 Vac Single-Phase, Three-Wire Catalog Number 120/208 Vac Three-Phase, Four-Wire Catalog Number 1200 #2 AWG–750 kcmil 19 Use three-phase 3MTB1200RCRIS 1600 #2 AWG–750 kcmil 19 Use three-phase 3MTB1600RCRIS Copper Bus (Standard Offering) 5 5 5 Notes 1 1200A main devices must be center fed when installing 800A residential meter stacks. 1600A main devices must be center fed when installing 800–1200A residential and commercial meter stacks. 2 For 400A units, to obtain (4) 750 kcmil cables per phase—order quantity 4 1MPLK2. Kit contains one lug. 3 For compression lug landing kits for 600A units, order 3MTB600CLK. Kit includes lug landings for three phases and neutral. 4 For 800A units, to obtain (4) 1/0–300 kcmil or (2) 1/0–750 kcmil cables per phase—order catalog number 3MTB800BLK, one lug kit per main terminal box ordered (neutral and ground included in kit). 5 For 800A and 1200A units, for compression lug landing kits, order 3MTB1200CLK. Kit includes lug landings for three-phase and neutral. 6 For 1200A units, to obtain (6) 1/0–300 kcmil or (3) 750 kcmil cables per phase—order catalog number 3MTB1200BLK, one lug kit per main terminal box ordered (neutral and ground included in kit). 7 Meets EUSERC electrical requirements and eliminates the need to add additional pull box section. 8 For 1600A units, to obtain (4) 750 kcmil cables per phase—order catalog number 3MTB1600BLK, one lug kit per main terminal box ordered. For a 1600A compression lug landing kit, order catalog number 3MTB1600CLK. 9 Quantity (10) lugs per phase—quantity (5) lugs incoming and quantity (5) lugs outgoing per phase. Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 5 5 5 5 5 5 V1-T5-103 5.10 5 5 5 5 5 Metering Products Group Metering Main Circuit Breaker ● Phase and neutral lugs included. If additional neutral lugs are needed, order 1MCB1200NLK for (3) 1/0–750 or (6) 1/0–300 kcmil ● For shunt trip mains, order the field-installable shunt trip kit in this volume, Tab 1, section 1.1 ● ● For overhead feed, use Myer type hub. Verify local utility approval For compression lugs on 400, 600, 800, 1000 and 1200A units, add CL to the end of the part number (includes copper lug pads for lines and neutral) ● ● 1200A or greater main devices must be center fed when installing 800A residential meter stacks 1400, 1600 and 2000A main devices must be center fed when installing 800 and 1200A residential and commercial meter stacks 5 5 Main Circuit Breaker 5 Main Circuit Breaker Main Ampere Rating 5 Main Circuit Breaker Type System Voltage Feed kAIC Line Side Lug and Wire Sizes (Lugs Included with Main Breaker) 1 120/240 Vac 120/208 Vac Single-Phase, Three-Wire Three-Phase, Four-Wire Catalog Number Catalog Number Aluminum Bus (Standard Offering) 5 250 KD Bottom/top 65 (2) 3/0–250 kcmil or (1) 2/0–500 kcmil 1MCB250R 3MCB250R 250 HKD Bottom/top 100 (2) 3/0–250 kcmil or (1) 2/0–500 kcmil 1MHCB250R 3MHCB250R 5 300 KD Bottom/top 65 (2) 3/0–250 kcmil or (1) 2/0–500 kcmil 1MCB300R 3MCB300R 300 HKD Bottom/top 100 (2) 3/0–250 kcmil or (1) 2/0–500 kcmil 1MHCB300R 3MHCB300R 5 350 KD Bottom/top 65 (2) 3/0–250 kcmil or (1) 2/0–500 kcmil 1MCB350R 3MCB350R 350 HKD Bottom/top 100 (2) 3/0–250 kcmil or (1) 2/0–500 kcmil 1MHCB350R 3MHCB350R 5 400 KD Bottom/top 65 (2) 3/0–250 kcmil or (1) 2/0–500 kcmil 1MCB400R 2 400 HKD Bottom/top 100 (2) 3/0–250 kcmil or (1) 2/0–500 kcmil 1MHCB400R 5 500 LD Bottom/top 65 (2) 400–500 kcmil 1MCB500R 3MCB500R 5 500 HLD Bottom/top 100 (2) 400–500 kcmil 1MHCB500R 3MHCB500R 600 LD Bottom/top 65 (2) 400–500 kcmil 1MCB600R 2 3MCB600R 2 600 HLD Bottom/top 100 (2) 400–500 kcmil 1MHCB600R 2 3MHCB600R 2 700 HMDL Bottom/top 100 (3) 3/0–400 kcmil 1MHCB700R 3MHCB700R 700 MDL Bottom/top 65 (3) 3/0–400 kcmil 1MCB700R 3MCB700R 3MCB800R 2 5 5 2 3MCB400R 2 3MHCB400R 2 800 MDL Bottom/top 65 (3) 3/0–400 kcmil 1MCB800R 2 5 800 MDL Bottom/top 65 (2) 500–750 kcmil 1MCB800R750 3MCB800R750 800 HMDL Bottom/top 100 (3) 3/0–400 kcmil 1MHCB800R 2 3MHCB800R 2 5 900 NGS Bottom/top 65 (4) 4/0–500 kcmil 3 1MCB900R 4 3MCB900R 4 900 NGH Bottom/top 100 (4) 4/0–500 kcmil 3 kcmil 3 1MHCB900R 4 3MHCB900R 4 1MCB1000R 24 3MCB1000R 24 5 1000 NGS Bottom/top 65 (4) 4/0–500 1000 NGS Bottom/top 65 (2) 500–750 kcmil 1MCB1000R750 3MCB1000R750 5 1000 NGH Bottom/top 100 (4) 4/0–500 kcmil 3 1MHCB1000R 24 3MHCB1000R 24 1200 NGS Bottom 65 (4) 4/0–500 kcmil 3 1MCB1200R 24 3MCB1200R 24 5 1200 NGH Bottom 100 (4) 4/0–500 kcmil 3 1MHCB1200R 24 3MHCB1200R 24 1200 NGS Bottom 65 (2) 500–750 kcmil Use three-phase 3MCB1200R750 5 Notes 1 If additional neutral lugs are needed, order 1MCB1200NLK [(3) 1/0–750 kcmil or (6) 1/0–300 kcmil]. 2 Add CL to end of catalog number for compression lug pads (includes lug pads for lines and neutral). 3 If (3) 500–750 kcmil are needed, order TA1201NB1. Order one kit per pole. 4 Main devices with a rating greater than 800A can be used with 800A residential modular stacks, but only as a center fed main. 5 5 5 5 5 5 5 V1-T5-104 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 5.10 Metering Products Group Metering Main Circuit Breaker Main Circuit Breaker 5 5 Main Circuit Breaker, continued Main Ampere Rating System Voltage Main Circuit Breaker Type Feed kAIC Line Side Lug and Wire Sizes (Lugs Included with Main Breaker) 1 120/240 Vac 120/208 Vac Single-Phase, Three-Wire Three-Phase, Four-Wire Catalog Number Catalog Number Aluminum Bus (EUSERC) 300 KD Bottom/top 65 Crimp lug landing pads (no lugs included) 1MCBE300R 3MCBE300R 350 KD Bottom/top 65 Crimp lug landing pads (no lugs included) 1MCBE350R 3MCBE350R 400 KD Bottom/top 65 Crimp lug landing pads (no lugs included) 1MCBE400R 3MCBE400R 400 HKD Bottom/top 100 Crimp lug landing pads (no lugs included) 1MHCBE400R 3MHCBE400R 500 LD Bottom/top 65 Crimp lug landing pads (no lugs included) 1MCBE500R 3MCBE500R 600 LD Bottom/top 65 Crimp lug landing pads (no lugs included) 1MCBE600R 3MCBE600R 600 HLD Bottom/top 100 Crimp lug landing pads (no lugs included) 1MHCBE600R 3MHCBE600R 800 MDL Bottom/top 65 Crimp lug landing pads (no lugs included) 1MCBE800R 3MCBE800R 5 5 5 5 5 5 5 5 800 HMDL Bottom/top 100 Crimp lug landing pads (no lugs included) 1MHCBE800R 3MHCBE800R 1000 NGS Bottom/top 65 Crimp lug landing pads (no lugs included) 1MCBE1000R 3MCBE1000R 1200 NGS Bottom 65 Crimp lug landing pads (no lugs included) 1MCBE1200R 3MCBE1200R 1200 NGH Bottom 100 Crimp lug landing pads (no lugs included) 1MHCBE1200R 3MHCBE1200R 5 5 5 Copper Bus (Premium Offering) 400 KD Bottom/top 65 (2) 3/0–250 kcmil or (1) 2/0-500 kcmil 1MCB400RC 2 3MCB400RC 2 400 HKD Bottom/top 100 2/0–500 kcmil 1MHCB400RC 2 3MHCB400RC 2 600 LD Bottom/top 65 (2) 300–500 kcmil 1MCB600RC 2 3MCB600RC 2 2 600 HLD Bottom/top 100 (2) 300–500 kcmil 1MHCB600RC 800 MDL Bottom/top 65 (3) 3/0–400 kcmil 1MCB800RC 2 5 3MHCB600RC 2 5 3MCB800RC 2 2 3MHCB800RC 2 800 HMDL Bottom/top 100 (3) 3/0–400 kcmil 1MHCB800RC 900 NGS Bottom/top 65 (4) 4/0–500 kcmil 3 1MCB900RC 4 3MCB900RC 4 900 NGH Bottom/top 100 (4) 4/0–500 kcmil 3 1MHCB900RC 4 3MHCB900RC 4 1000 NGS Bottom/top 65 (2) 500–750 kcmil 1MCB1000R750C 3MCB1000R750C 1000 NGS Bottom/top 65 (4) 4/0–500 kcmil 3 1MCB1000RC 24 3MCB1000RC 24 1000 NGH Bottom/top 100 (4) 4/0–500 kcmil 3 1MHCB1000RC 24 3MHCB1000RC 24 1200 NGS Bottom 65 (2) 500–750 kcmil Use three-phase 3MCB1200R750C kcmil 3 1200 NGS Bottom 65 (4) 4/0–500 1200 NGH Bottom 100 (4) 4/0–500 kcmil 3 1MCB1200RC 24 3MCB1200RC 5 5 24 1MHCB1200RC 24 3MHCB1200RC 24 46 46 kcmil 5 1MCB1400RBC 1400 RGH Bottom 100 (4) 500–1000 1400 RGH Top 100 (4) 500–1000 kcmil 5 1MCB1400RT 7 3MCB1400RBC 3MCB1400RT 7 1600 RGH Bottom 100 (4) 500–1000 kcmil 5 1MCB1600RBC 67 3MCB1600RBC 67 1600 RGH Top 100 (4) 500–1000 kcmil 5 1MCB1600RT 7 3MCB1600RT 7 2000 RGH Bottom 100 (6) #2–600 kcmil 1MCB2000RBC 68 3MCB2000RBC 68 2000 RGH Top 100 (6) #2–600 kcmil 1MCB2000RT 8 3MCB2000RT 8 Bottom 100 Crimp lug landing pads (no lugs included) 1MCBE1000RC 3MCBE1000RC NGH 1200 NGS Bottom 65 Crimp lug landing pads (no lugs included) 1MCBE1200RC 3MCBE1200RC 1200 NGH Bottom 100 Crimp lug landing pads (no lugs included) 1MHCBE1200RC 3MHCBE1200RC 5 5 5 5 5 5 Notes 1 If additional neutral lugs are needed, order 1MCB1200NLK [(3) 1/0–750 kcmil or (6) 1/0–300 kcmil]. 2 Add CL to end of catalog number for compression lug pads (includes lug pads for lines and neutral). 3 If (3) 500–750 kcmil are needed, order TA1201NB1. Order one kit per pole. 4 Main devices with a rating greater than 800A can be used with 800A residential modular stacks but only as a center fed main. 5 If (6) #2–600 kcmil lugs are needed, order TA2000RD. Catalog number includes terminals and hardware for three poles. If neutral is needed, order TA2000N. 6 Copper bus. 7 Main devices with a rating greater than 1200A can be used with residential and commercial modular metering stacks but only as a center fed main. 8 Only to be used in center feed applications with 1200A meter stacks. Not to be used with 800A stacks. Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 5 5 Copper Bus (EUSERC) 1000 5 5 5 5 5 V1-T5-105 5.10 Metering Products Group Metering 5 Main Fusible Switches ● Fuses not included ● Main lugs and neutral included with device ● 100 kAIC rating on switches with Class T fuses installed. If converting to Class H, the kAIC rating is 10 and if converted to Class R, the kAIC rating is 200 5 Note: This is the fuse rating, switch still rated at 100 kAIC. 5 5 5 5 ● ● 800A top and bottom fed units are supplied with Class T fuse clips as standard. The Class T fuse clips are field convertible to Class L by repositioning. No kit is needed Barrier kits available for 400A–800A fusible switches: Bottom feed—3MFSBBK, Top feed—3MFSTBK 5 5 Main Fusible Switches Main Fusible Switches System Voltage 5 Class Fuse Clips (Fuses Not Included) 5 Ampere Rating 5 Aluminum Bus (Standard Offering) 400 5 Feed Bottom Line Side Box Lugs and Wire Sizes (Included with Switch) 120/240 Vac Single-Phase, Three-Wire 120/208 Vac Three-Phase, Four-Wire Catalog Number Catalog Number T1 (2) 1/0–300 kcmil or (1) 750 kcmil 45 1MFS400RB 3MFS400RB 1 (2) 1/0–300 kcmil or (1) 750 kcmil 56 1MFS400RT 3MFS400RT 400 Top T 600 Bottom T2 (2) #2–600 kcmil 45 1MFS600RB 3MFS600RB 5 600 Top T2 (2) #2–600 kcmil 56 1MFS600RT 3MFS600RT 5 800 Bottom T, L 3 (4) 3/0–750 kcmil 4 1MFS800RB 3MFS800RB 800 Top T, L 3 (4) 3/0–750 kcmil 6 1MFS800RT 3MFS800RT 1MFS1200RB 3MFS1200RB 3MFS400RBC 5 1200 5 400 Bottom T, L 3 (4) #2–600 kcmil 7 Copper Bus (Premium Offering) Bottom T1 (2) 1/0–300 kcmil or (1) 750 kcmil 45 1MFS400RBC 1 (2) 1/0–300 kcmil or (1) 750 kcmil 56 1MFS400RTC 3MFS400RTC 3MFS600RBC 400 Top T 600 Bottom T2 (2) #2–600 kcmil 45 1MFS600RBC 5 600 Top T2 (2) #2–600 kcmil 56 1MFS600RTC 3MFS600RTC 800 Bottom T, L 3 (4) 3/0–750 kcmil 4 1MFS800RBC 3MFS800RBC 5 800 Top T, L 3 (4) 3/0–750 kcmil 6 1MFS800RTC 3MFS800RTC 1MFS1200RBC 3MFS1200RBC 5 1200 5 Bottom T, L 3 (4) #2–600 kcmil 7 Notes 1 If Class H fuse clips are needed, use catalog number WCG3HK400 (order (1) per phase). If Class R fuse clips are needed, order catalog number DS56FK in addition to WCG3HK400. In order to go from T to R, the device must first be converted to H. All kits are field installable and each DS56FK kit will convert three poles. 2 If Class H fuse clips are needed, use catalog number WCG3HK600 (order (1) per phase). If Class R fuse clips are needed, order catalog number DS66FK in addition to WCG3HK600. In order to go from T to R, the device must first be converted to H. All kits are field installable and each DS66FK kit will convert three poles. 3 Class T fuse clips provided are field convertible to Class L by repositioning. No kit is needed. 4 If compression lugs are being used, order 3MFS800CLK. This compression lug kit includes four pads (three poles and neutral). 5 1MFS600BLK (4) 3/0–750 kcmil/phase (one kit/phase and one kit/neutral). 6 If compression lugs are being used, order 3MFS800CLKT. This compression lug kit includes four pads (three poles and neutral). 7 IMFS1200LK (3) 750 kcmil/phase (one kit/phase). IMFS1200LKN (3) 750 kcmil (neutral). 5 5 5 5 5 5 5 5 5 5 V1-T5-106 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 5.10 Metering Products Group Metering Main Fusible Switch with Utility Pull Box ● Fuses not included ● Includes lug landing pads on line side and neutral ● Spacer kit 3MMBSK required when stacks are mounted on right-hand side in EUSERC areas ● 100 kAIC rating on switches with Class T fuse clips installed Main Fusible Switch with Utility Pull Box 5 5 5 5 5 5 5 Main Fusible Switch with Utility Pull Box System Voltage Ampere Rating Feed Class Fuse Clips (Fuses Not Included) Line Side Box Lugs and Wire Sizes (Included with Switch) 120/240 Vac Single-Phase, Three-Wire 120/208 Vac Three-Phase, Four-Wire Catalog Number Catalog Number 5 5 5 Aluminum Bus (Standard Offering) 400 Bottom T 1 1MFS400RUG 3MFS400RUG 600 Bottom T 1 1MFS600RUG 3MFS600RUG 800 Bottom T, L 1 1MFS800RUG 3MFS800RUG 1200 Bottom T 1 1MFS1200RUG 3MFS1200RUG 5 5 5 Copper Bus (Premium Offering) 400 Bottom T 1 1MFS400RUGC 3MFS400RUGC 600 Bottom T 1 1MFS600RUGC 3MFS600RUGC 1MFS800RUGC 3MFS800RUGC 1MFS1200RUGC 3MFS1200RUGC 800 Bottom T, L 1 1200 Bottom T 1 5 5 5 Utility Pull Box ● Includes lug landing pads on line side and neutral ● Requires cable connection in field to main device; does not include horizontal cross bus 5 5 5 5 5 Pull Box System Voltage Ampere Rating Feed Line Side Lug Information 120/240 Vac Single-Phase, Three-Wire 120/208 Vac Three-Phase, Four-Wire Catalog Number Catalog Number 5 5 Aluminum Bus (Standard Offering) Bottom 1 1/0–750 kcmil or (2) 1/0–300 kcmil 1UGPB400R 3UGPB400R 800 Bottom 1 (2) 1/0–750 kcmil or (4) 1/0–300 kcmil 1UGPB800R 3UGPB800R 1200 Bottom 1 (4) #2–600 kcmil 1UGPB1200R 3UGPB1200R 3UGPB400RC 400 5 5 Copper Bus (Premium Offering) Bottom 1 1/0–750 kcmil or (2) 1/0–300 kcmil 1UGPB400RC 800 Bottom 1 (2) 1/0–750 kcmil or (4) 1/0–300 kcmil 1UGPB800RC 3UGPB800RC 1200 Bottom 1 (4) #2–600 kcmil 1UGPB1200RC 3UGPB1200RC 400 5 Load Side Lug Information for Cable Connection to Main Disconnect 5 5 Note 1 Pull box section includes landing studs for line side compression lugs. Wire sizes refer to load side connection. 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-107 5.10 5 5 5 5 5 5 5 5 Metering Products Group Metering Main Bolted Pressure Contact Switches ● Add suffix ST to catalog number for shunt trip ● Fuses not included ● 100 kAIC rating on switches with Class L fuses installed Main Bolted Pressure Contact Switches System Voltage Ampere Rating Feed 120/240 Vac Single-Phase, Three-Wire Class Fuse Clips (Fuses Not Included) Catalog Number 120/208 Vac Three-Phase, Four-Wire Catalog Number Line Side Box Lugs and Wire Sizes (Included) Copper Bus 5 1200 Bottom L 1BPS1200RB 3BPS1200RB (4) #4–600 kcmil 1200 Top L 1BPS1200RT 3BPS1200RT (4) #4–600 kcmil 5 1600 Bottom L Use three-phase 3BPS1600RB (6) #4–600 kcmil 1600 Top L Use three-phase 3BPS1600RT (6) #4–600 kcmil 2000 Bottom L Use three-phase 3BPS2000RB (8) #4–600 kcmil 2000 Top L Use three-phase 3BPS2000RT (8) #4–600 kcmil 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 V1-T5-108 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Group Metering Main Circuit Breaker with Busway Connection Verify proper left/right–bus/main phasing. Note: “Right” means that the bus duct is to the right of the main and “left” means that the bus duct is to the left of the main. (See Dimension/ Layout section for clarification.) Feed 400 Bottom 600 Bottom 800 Bottom 400 Bottom 600 Bottom 800 Bottom 400 Bottom 600 Bottom 800 Bottom 400 Bottom 600 Bottom 800 Bottom 400 Bottom 600 Bottom 800 Bottom 400 Bottom 600 Bottom 800 Bottom 400 Bottom 600 Bottom 800 Bottom 400 Bottom 600 Bottom 800 Bottom 400 Bottom 400 Bottom 600 Bottom 600 Bottom 800 Bottom 800 Bottom 1000 Bottom 1000 Bottom 1200 Bottom 1200 Bottom 400 Bottom 400 Bottom 600 Bottom 600 Bottom 800 Bottom 800 Bottom 1000 Bottom 1000 Bottom 1200 Bottom 1200 Bottom 400 Bottom 400 Bottom System Voltage 120/208 Vac Three-Phase, Four-Wire Catalog Number Internal Ground or Housing Ground Standard T or TO Right Opposite or Left Phasing Side Ampere Rating Feed 3MFS400BCRGTO 3MFS600BCRGTO 3MFS800BCRGTO 3MFS400BCLGTO 3MFS600BCLGTO 3MFS800BCLGTO 3MFS400BCRGT 3MFS600BCRGT 3MFS800BCRGT 3MFS400BCLGT Internal TO Right 1200 Bottom Internal TO Right 1200 Bottom Internal TO Right 400 Bottom Internal TO Left 400 Bottom Internal TO Left 600 Bottom Internal TO Left 600 Bottom Internal T Right 800 Bottom Internal T Right 800 Bottom Internal T Right 1000 Bottom Internal T Left 1000 Bottom 3MFS600BCLGT 3MFS800BCLGT 3MFS400BCRNTO Internal T Left 1200 Bottom Internal T Left 1200 Bottom Housing TO Right 400 Bottom 3MFS600BCRNTO 3MFS800BCRNTO 3MFS400BCLNTO 3MFS600BCLNTO 3MFS800BCLNTO 3MFS400BCRNT 3MFS600BCRNT 3MFS800BCRNT 3MFS400BCLNT 3MFS600BCLNT 3MFS800BCLNT 3MCB400BCRGT Housing TO Right 400 Bottom Housing TO Right 600 Bottom Housing TO Left 600 Bottom Housing TO Left 800 Bottom Left 800 Bottom T Right 1000 Bottom Housing T Right 1000 Bottom Housing T Right 1200 Bottom Bottom Housing T Left 1200 Housing T Left 400 Bottom Bottom T Left Internal T Right 600 Bottom 3HMCB400BCRGT 3MCB600BCRGT 3HMCB600BCRGT Internal T Right 600 Bottom Internal T Right 800 Bottom Internal T Right 800 Bottom Internal T Right 1000 Bottom Internal T Right 1000 Bottom Internal T Right 1200 Bottom Internal T Right 1200 Bottom Internal T Right 400 Bottom Internal T Right 400 Bottom Internal T Left 600 Bottom Internal T Left 600 Bottom Internal T Left 800 Bottom Internal T Left 800 Bottom Internal T Left 1000 Bottom Internal T Left 1000 Bottom Internal T Left 1200 Bottom Internal T Left 1200 Bottom Internal T Left 400 Bottom Internal T Left 400 Bottom Housing T Right 600 Bottom Housing T Right 600 Bottom Bottom Bottom 800 Bottom 1000 Bottom 1000 Bottom 3HMBC1000BCRNT Bottom TO Housing Housing 800 Bottom 600 Housing 400 3MCB800BCRGT 3HMCB800BCRGT 3MCB1000BCRGT 3HMCB1000BCRGT 3MCB1200BCRGT 3HMCB1200BCRGT 3MCB400BCLGT 3HMCB400BCLGT 3MCB600BCLGT 3HMCB600BCLGT 3MCB800BCLGT 3HMCB800BCLGT 3MCB1000BCLGT 3HMCB1000BCLGT 3MCB1200BCLGT 3HMCB1200BCLGT 3MCB400BCRNT 3HMCB400BCRNT 3MCB600BCRNT 3HMCB600BCRNT 3MCB800BCRNT 3HMCB800BCRNT 3MBC1000BCRNT 600 Using this information, select the correct main device catalog number per the selection chart. Main Circuit Breaker with Busway Connection, continued Main Circuit Breaker with Busway Connection Ampere Rating 5.10 Housing T Right 800 Housing T Right 800 Bottom Bottom Housing T Right 1000 Housing T Right 1000 Bottom Housing T Right 1200 Bottom Housing T Right 1200 Bottom System Voltage 120/208 Vac Three-Phase, Four-Wire Catalog Number Internal Ground or Housing Ground Standard T or TO Right Opposite or Left Phasing Side 3MCB1200BCRNT 3HMCB1200BCRNT 3MCB400BCLNT 3HMCB400BCLNT 3MCB600BCLNT 3HMCB600BCLNT 3MCB800BCLNT Housing T Right Housing T Right Housing T Left Housing T Left Housing T Left Housing T Left Housing T Left 3HMCB800BCLNT 3MCB1000BCLNT 3HMCB1000BCLNT 3MCB1200BCLNT 3HMCB1200BCLNT 3MCB400BCRGTO Housing T Left Housing T Left Housing T Left Housing T Left Housing T Left Internal TO Right 3HMCB400BCRGTO 3MCB600BCRGTO 3HMCB600BCRGTO Internal TO Right Internal TO Right Internal TO Right 3MCB800BCRGTO 3HMCB800BCRGTO 3MCB1000BCRGTO 3HMCB1000BCRGTO 3MCB1200BCRGTO 3HMCB1200BCRGTO 3MCB400BCLGTO 3HMCB400BCLGTO 3MCB600BCLGTO 3HMCB600BCLGTO 3MCB800BCLGTO 3HMCB800BCLGTO Internal TO Right Internal TO Right Internal TO Right Internal TO Right Internal TO Right Internal TO Right Internal TO Left Internal TO Left Internal TO Left Internal TO Left Internal TO Left Internal TO Left 3MCB1000BCLGTO 3HMCB1000BCLGTO 3MCB1200BCLGTO 3HMCB1200BCLGTO 3MCB400BCRNTO 3HMCB400BCRNTO 3MCB600BCRNTO 3HMCB600BCRNTO 3MCB800BCRNTO 3HMCB800BCRNTO 3MCB1000BCRNTO 3HMCB1000BCRNTO 3MCB1200BCRNTO 3HMCB1200BCRNTO 3MCB400BCLNTO 3HMCB400BCLNTO 3MCB600BCLNTO 3HMCB600BCLNTO 3HMCB800BCLNTO 3HMCB800BCLNTO 3MCB1000BCLNTO 3HMCB1000BCLNTO 3MCB1200BCLNTO 3HMCB1200BCLNTO Internal TO Left Internal TO Left Internal TO Left Internal TO Left Housing TO Right Housing TO Right Housing TO Right Housing TO Right Housing TO Right Housing TO Right Housing TO Right Housing TO Right Housing TO Right Housing TO Right Housing TO Left Housing TO Left Housing TO Left Housing TO Left Housing TO Left Housing TO Left Housing TO Left Housing TO Left Housing TO Left Housing TO Left Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-109 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5.10 5 5 Metering Products Group Metering Dimensions Approximate Dimensions in Inches (mm) Dimensions (Not to be Used for Construction Purposes) 5 Center Line of Wall Mounting Bracket Knockouts in Bottom Endwalls Except No KOs for Top Feed Switch or Bolted Pressure Switch Conduit Diameter Width Height Depth Mounting A B C D E F Inches mm 400 and 600A 13.50 (342.9) 48.75 (1238.3) 7.00 (177.8) — 54.00 (1371.6) 30.63 (777.9) (1) 2.50, 3.00, 3.50, 4.00 (1) 0.50 (1) 63.5, 76.2, 88.9, 101.6 (1) 12.7 1 800 and 1200A 20.00 (508.0) 47.63 (1209.8) 11.75 (298.5) 12.00 (304.8) 51.50 (1308.1) 30.63 (777.9) (2) 12.1, 19.1, 25.4 (4) 50.8, 63.5, 76.2, 88.9, 101.6 2 5 (2) 0.50, 0.75, 1.00 (4) 2.00, 2.50, 3.00, 3.50, 4.00 1600A 32.88 (835.2) 60.13 (1527.3) 11.44 (290.6) 16.00 (406.4) 64.13 (1628.9) 38.59 (980.2) (1) 19.1, 25.4, 31.8, 38.1 (5) 76.2, 88.9, 101.6, 127.0 3 5 (1) 0.75, 1.00, 1.25, 1.50 (5) 3.00, 3.50, 4.00, 5.00 Main Circuit Breaker with Box Lugs 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Main Device KO Dwg. Terminal Box 400–1200A 20.00 (508.0) 47.63 (1209.8) 11.75 (298.5) 12.00 (304.8) 51.50 (1308.1) 30.63 (777.9) (2) 0.50, 0.75, 1.00 (4) 2.00, 2.50, 3.00,3.50, 4.00 (2) 12.7, 19.1, 25.4 (4) 50.8, 63.5, 76.2, 88.9, 101.6 2 1400–2000A 24.88 (632.0) 57.13 (1451.0) 14.88 (378.0) 16.00 (406.4) 57.13 (1451.0) 44.00 (1117.6) — — — Main Circuit Breaker with Compression Lugs 400–1200A 20.00 (508.0) 61.00 (1549.4) 11.75 (298.5) 12.00 (304.8) 65.00 (1651.0) 44.00 (1117.6) (2) 0.50, 0.75, 1.00 (4) 2.00, 2.50, 3.00, 3.50, 4.00 (2) 12.7, 19.1, 25.4 (4) 50.8, 63.5, 76.2, 88.9, 101.60 2 Main Fusible Switch Bottom feed 400–800A 20.00 (508.0) 47.63 (1209.8) 11.75 (298.5) 12.00 (304.8) 51.50 (1308.1) 30.63 (777.9) (2) 0.50, 0.75, 1.00 (4) 2.00, 2.50, 3.00, 3.50, 4.00 (2) 12.7, 19.1, 25.4 (4) 50.8, 63.5, 76.2, 88.9, 101.6 2 Top feed 400–800A 20.00 (508.0) 47.63 (1209.8) 11.75 (298.5) 12.00 (304.8) 51.50 (1308.1) 18.13 (460.4) (2) 0.50, 0.75, 1.00 (4) 2.00, 2.50, 3.00, 3.50, 4.00 (2) 12.7, 19.1, 25.4 (4) 50.8, 63.5, 76.2, 88.9, 101.6 2 1200A 33.50 (850.9) 52.75 (1339.9) 11.88 (301.8) 16.00 (406.4) 56.25 (1428.8) 30.75 (781.1) (5) 3.50, 4.00, 5.00 (1) 0.75, 1.00, 1.25, 1.50 (5) 88.9, 101.6, 127.0 (1) 19.1, 25.4, 31.8, 38.1 4 66.50 (1689.1) 19.50 (495.3) 28.00 (711.2) 60.00 (1524.0) 30.63 (777.9) — — — Bolted Pressure Switch 36.50 (927.1) Main Fusible Switch with Pull Box 400A 20.00 (508.0) 61.00 (1549.4) 11.75 (298.5) 12.00 (304.8) 65.00 (1651.0) 44.00 (1117.6) (2) 0.50, 0.75, 1.00 (4) 2.00, 2.50, 3.00, 3.50, 4.00 (2) 12.7, 19.1, 25.4 (4) 50.8, 63.5, 76.2, 88.9, 101.6 2 600 and 800A (single-phase) 20.00 (508.0) 61.00 (1549.4) 11.75 (298.5) 12.00 (304.8) 65.00 (1651.0) 44.00 (1117.6) (2) 0.50, 0.75, 1.00 (4) 2.00, 2.50, 3.00, 3.50, 4.00 (2) 12.7, 19.1, 25.4 (4) 50.8, 63.5, 76.2, 88.9, 101.6 2 600 and 800A (three-phase) 25.06 (636.5) 61.00 (1549.4) 11.75 (298.5) 17.00 (431.8) 65.00 (1651.0) 44.00 (1117.6) (2) 0.50, 0.75, 1.00 (4) 2.00, 2.50, 3.00, 3.50, 4.00 (2) 12.7, 19.1, 25.4 (4) 50.8, 63.5, 76.2, 88.9, 101.6 4 1200A 33.50 (850.9) 61.50 (1562.1) 11.88 (301.8) 16.00 (406.4) 65.25 (1657.4) 48.00 (1219.2) (5) 3.50, 4.00, 5.00 (1) 0.75, 1.00, 1.25, 1.50 (5) 88.9, 101.6, 127.0 (1) 19.1, 25.4, 31.8, 38.1 4 5 Main Circuit Breaker with Pull Box (EUSERC) 5 400A 20.01 (508.2) 60.44 (1535.2) 11.14 (283.0) 12.00 (304.8) 65.11 (1653.8) 39.75 (1009.6) (4) 2.50, 3.00, 3.50, 4.00 (4) 63.5, 76.2, 88.9, 101.6 2 800A 24.88 (632.0) 60.94 (1547.9) 11.14 (283.0) 17.00 (431.8) 64.88 (1648.0) 39.81 (1011.2) (4) 2.50, 3.00, 3.50, 4.00 (4) 63.5, 76.2, 88.9, 101.6 2 1200A 33.00 (838.2) 61.14 (1553.0) 11.32 (287.5) 16.00 (406.4) 65.25 (1657.4) 43.56 (1106.4) (4) 2.50, 3.00, 3.50, 4.00 (4) 63.5, 76.2, 88.9, 101.6 4 5 5 5 5 5 5 5 5 5 Pull Box 400A 16.38 (416.1) 44.88 (1140.0) 7.88 (200.2) 8.00 (203.2) 45.75 (1162.1) 28.63 (727.2) (2) 4.00 101.6 5 800A 24.38 (619.3) 46.88 (1190.8) 11.88 (301.8) 12.00 (304.8) 47.75 (1212.9) 32.25 (819.2) (3) 4.00 101.6 6 1200A 32.50 (825.5) 56.88 (1444.8) 12.00 (304.8) 17.75 (450.9) 57.75 (1466.9) 42.25 (1073.2) (4) 5.00 127.0 7 EUSERC Bussed Pull Section Single-phase 400 and 800A 20.13 (511.3) 61.00 (1549.4) 11.25 (285.8) 12.00 (304.8) 64.88 (1648.0) 44.00 (1117.6) (4) 2.50, 3.00, 3.50, 4.00 (4) 63.5, 76.2, 88.9, 101.6 5 Three-phase 400 and 800A 25.13 (638.3) 61.00 (1549.4) 11.88 (301.8) 17.00 (431.8) 64.88 (1648.0) 44.00 (1117.6) (4) 2.50, 3.00, 3.50, 4.00 (4) 63.5, 76.2, 88.9, 101.6 6 EUSERC Main Terminal Box Single-phase 400 and 800A 20.13 (511.3) 61.00 (1549.4) 11.88 (301.8) 12.00 (304.8) 64.88 (1648.0) 44.00 (1117.6) (2) 0.50, 0.75, 1.00 (2) 12.7, 19.1, 25.4 2 Three-phase 400A 20.13 (511.3) 61.00 (1549.4) 11.88 (301.8) 12.00 (304.8) 64.88 (1648.0) 44.00 (1117.6) (4) 2.00, 2.50, 3.00, 3.50, 4.00 (4) 50.8, 63.5, 76.2, 88.9, 101.6 2 Three-phase 800A 25.13 (638.3) 61.00 (1549.4) 11.88 (301.8) 17.00 (431.8) 64.88 (1648.0) 44.00 (1117.6) (4) 2.00, 2.50, 3.00, 3.50, 4.00 (4) 50.8, 63.5, 76.2, 88.9, 101.6 2 V1-T5-110 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 5.10 Metering Products Group Metering Approximate Dimensions in Inches (mm) Main Circuit Breakers, Terminal Boxes and Pull Boxes 5 Bolted Pressure Switch A A 5 C 5 5 E 5 B E 5 B F F 5 5 C D Top Feed Fusible Switch 5 EUSERC Main Terminal Box C A 5 25.00 (635.0) D Main CB, Non-Euserc Terminal Box and Pullboxes A 5 C 5 5 E 5 B B 5 5 F 5 5 17.00 (431.8) Top Feed Switch (No Knockouts) D 5 Bottom Feed Fusible Switch and Combination Fusible Switch with Pull Box 5 5 C A 5 5 E 5 B 5 F 5 5 17.00 (431.8) Bottom Feed Switch and Combination Switch/Pullbox D 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-111 5.10 5 5 5 5 5 Group Metering Approximate Dimensions in Inches (mm) Knockout 5 Knockout 1 .625 .010 .080 .020 5.375 .010 3.500 .010 6.850 .020 KO (10) KO (10) 7.000 +.000 –.030 3.000 .020 Stamped ID Mark .200 .020 Typ. .780 .020 Typ. 12.375 .010 .175 .010 +.003 .169 –.000 Diameter 5 Hole Knockout 6 Knockout 2 .45 22.54 11.62 .61 .250 Ref. 3.75 10.38 2.50 5 5 6.120 .020 CL .438 .010 5 5 2.880 .030 3.010 .010 .150 .020 Typ. .875 .020 5 5 3.250 .020 KO (44) 5 5 .150 .020 Typ. .080 .020 2.880 .010 .800 .030 6.000 .020 5.000 .020 2-1/2”, 3”, 3-1/2”, 4” KO 1 Knockout Required .310 .030 Diameter 2.500 Paint Hole .020 1/2”Knockout 1 Required Per 50-1827-1 KO (1) 6.500 Outside .010 5 Metering Products .150 .020 Typ. 1.93 4.250 .150 .020 .020 Typ. 3.25 2.50 1.75 4.25 .220 Dia. .250 Paint Ref. Hole 11.19 2 Knockouts for 1/2”, 3/4” or 1” Conduit .281 Diameter Knockout 1 Required 6.000 .020 6.000 .020 6.000 .020 10.120 .020 KO (10) KO (10) 11.000 +.000 -.030 10.850 .020 KO (10) 4.000 .020 .16 4 Knockouts for 2-1/2”, 3”, 3-1/2” or 4” Conduit .200 .020 Typ. 8.00 8.00 .780 .020 Typ. 4.00 A 19.40 5 5 5 5 6.000 .010 6.000 .010 1.500 .020 4.250 .020 5.125 .020 7.250 .020 .220 Dia. Paint Hole 7.250 .020 7.250 .020 .150 .020 Typ. .350 Ref. KO (11) 10.140 .020 KO (11) 10.850 .020 .130 .030 6.000 .010 6.000 .010 3”, 3-1/2”, 4”, 5” Knockout Per A50-26327 5 Knockouts Required 6.000 .010 6.000 .010 .169 .002 Diameter 5 Holes Required at ”X” KO (11) 11.000 +.000 –.030 4.000 .020 .685 .020 Typ. .125 .030 .120 .020 Typ. 4.440 .020 Knockout 8 Knockout 4 .45 22.54 11.62 .61 .281 Dia. Knockout 1 Required 3.75 10.38 2.50 2 Knockouts for 1/2", 3/4", or 1" Conduit 1.93 3.25 2.50 1.75 5 .150 .020 Typ. .350 Ref. KO (11) 5 5 6.000 .010 2.750 .010 5 5 6.000 .010 1.440 .020 2.125 .020 5 5 32.120 .020 6.000 .010 2.750 7.500 .010 .020 2.750 .010 5 5 2.125 .020 3/4”, 1”, 1-1/4”, 1-1/2” Knockout Per A50-26319 1 Knockout Required 4.000 .020 .380 .020 5 5 Knockout 7 Knockout 3 4 Knockouts for 2-1/2", 3", 3-1/2" or 4" Conduit 24.38 2 Knockouts for 1/2", 3/4", or 1" Conduit 8.00 4.00 8.00 4.25 11.19 2 Knockouts for 1/2”, 3/4” or 1” Conduit 4.25 .281 Diameter Knockout 1 Required 4 Knockouts for 2-1/2”, 3”, 3-1/2” or 4” Conduit B .16 4.75 3.13 1.75 1.75 2.50 8.00 8.00 4.00 1.50 0.50 19.40 15.38 16.63 2.50 3.63 27.13 5 V1-T5-112 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 3.75 2.13 11.25 Metering Products Group Metering 5.10 Approximate Dimensions in Inches (mm) 5 Layout—Main Fusible Switch 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-113 5.10 5 5 5 Metering Products Group Metering Approximate Dimensions in Inches (mm) Main Circuit Breaker—“T-Opposite” Phasing Right 8.48 (215.4) CLVertical Wall 5 Main Circuit Breaker—“Standard T” Phasing Right 8.48 (215.4) CLVertical Wall 5 5 Meter Center Front 5 T-Opposite 38.76 (984.5) 5 T-Opposite 5 Meter Center Front 38.76 (984.5) CL Horizontal 18.17 (461.5) 18.17 (461.5) 5 T-Opposite 20.00 (508.0) 6.00 (152.4) 5 T-Opposite 5 CL Horizontal 20.00 (508.0) 30.08 (764.0) 6.00 (152.4) 30.08 (764.0) Floor 5 Floor 5 5 5 Main Circuit Breaker—“T-Opposite” Phasing Left Main Circuit Breaker—“Standard T” Phasing Left 5 5 8.48 Wall (215.4) CLVertical 8.48 Wall (215.4) CLVertical 5 5 Meter Center Front T-Opposite 5 5 T-Opposite 5 38.76 (984.5) 38.76 (984.5) CL Horizontal 18.17 (461.5) 5 5 T-Opposite 30.08 (764.0) T-Opposite 5 5 Meter Center Front 18.17 (461.5) 20.00 (508.0) 6.00 (152.4) 20.00 (508.0) 30.08 (764.0) 6.00 (152.4) Floor Floor 5 5 5 V1-T5-114 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com CL Horizontal Metering Products Group Metering 5.10 Contents Surge Metering Description Surge suppression devices shown are factory mounted in Group Metering Enclosure. Page Systems for Residential and Commercial Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type CCV 120/240V Tenant Main Circuit Breaker . Type CV 120/240V Tenant Main Circuit Breaker . . Meter Packs—1MP, 1MM and 3MM Main Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . . Main Service Modules . . . . . . . . . . . . . . . . . . . . . Surge Metering Residential Meter Stacks. . . . . . . . . . . . . . . . . . . . 1MP, 1MM and 3MM Main Tenant Circuit Breakers. . . . . . . . . . . . . . . . . . . . . . . . . . Phase Balanced Stack . . . . . . . . . . . . . . . . . . . . . . Commercial Meter Stack Modules . . . . . . . . . . . . 35MM, 37MM, 35SS and 37SS Main Tenant Circuit Breakers . . . . . . . . . . . . . . . V1-T5-88 V1-T5-90 V1-T5-95 V1-T5-96 V1-T5-98 V1-T5-101 5 5 5 5 5 5 V1-T5-116 5 V1-T5-125 V1-T5-126 V1-T5-127 5 V1-T5-134 5 5 5 Surge Metering Product Description Eaton’s multiple metering product family is proud to announce the availability of main surge devices. The new main surge is mounted between the main service module and the meter stacks and serves the purpose of providing surge protection for downstream multiple metering products. The main surge is compatible with all meter stacks currently manufactured (1MM, 3MM, 35MM and 37MM). Features, Benefits and Functions ● ● ● ● Uses thermally protected metal oxide varistor (MOV) technology Compatible with 37MM enclosure accessories Protection status indicator lights EMI/RFI filtering and audible alarms Offers surge protection for all units fed from a main service module Standards and Certifications ● ● ● Benefit for building/complex owners who want to offer surge protection to their tenants. Owner can market their apartment complex as being surge friendly to appliances and electronics Attain local utility company approval. Not for use in EUSERC area UL 1449 3rd Edition recognized component 5 5 5 5 5 5 5 5 Product Selection 5 Surge Metering 5 Voltage Surge Current per Phase (kA) Diagnostics Catalog Number 5 120/240V single-phase 100 Standard 1MMSURGE 208Y/120V three-phase 100 Standard 3MMSURGE 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-115 5.10 5 Metering Products Group Metering Contents 1MM and 3MM Metering Stack Modules Description 5 5 5 5 5 5 5 5 5 5 Residential Meter Stacks 5 Features, Benefits and Functions 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Page Systems for Residential and Commercial Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type CCV 120/240V Tenant Main Circuit Breaker . Type CV 120/240V Tenant Main Circuit Breaker . . Meter Packs—1MP, 1MM and 3MM Main Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . Main Service Modules . . . . . . . . . . . . . . . . . . . . . Surge Metering. . . . . . . . . . . . . . . . . . . . . . . . . . . Residential Meter Stacks 1MP, 1MM and 3MM Main Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . Phase Balanced Stack. . . . . . . . . . . . . . . . . . . . . . Commercial Meter Stack Modules . . . . . . . . . . . . 35MM, 37MM, 35SS and 37SS Main Tenant Circuit Breakers . . . . . . . . . . . . . . . A. Barrier Meter socket and tenant main breaker/wireway sections are separated by a solid metal barrier to guard unmetered bus against power theft. B. Tenant Breaker Reliable busbar–to–busbar connection. 200A modules accept bolt-on breakers 60– 200A. 125A modules accept 15–125A plug-on breakers. C. Moveable Phase Connector Four-wire horizontal bus lets you use any 3MM module for single- or three-phase incoming service. Shipped with A and B phase connection, phase balancing is easily accomplished in the field by moving one, frontaccessible phase connector post per module. D. Neutral Assembly A convenient termination for neutral conductors is in the wireway of each module. 5 5 5 E. Enclosed Horizontal Bus Added security because a non-removable barrier encloses the 800 or 1200A horizontal bus passing through tenant breaker section. F. Equipment Ground Bar Factory installed in side gutter, a standard feature that’s moveable to the top or bottom gutter. G. Raintight Cap Shipped on each outdoor meter module and main device. H. Knockouts Tangential in bottom endwall. I. Superior Finish Rust inhibiting phosphate primer and gray baked enamel is standard. All outdoor enclosures are of galvanized steel construction. K. Bus Connection Mains and modules slip together quickly and smoothly with frontaccessible captive bolts securing the juncture without removing socket interiors or bus access plate. Main bus joint bolts torque to 25 foot pounds. L. Separate Wireway Cover Separate covers allow easy access to tenant breaker and wireway section, permit work on breakers or in wireway without disturbing meters or meter covers. (Not shown.) 5 V1-T5-116 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-98 V1-T5-101 V1-T5-115 V1-T5-125 V1-T5-126 V1-T5-127 V1-T5-134 1MM Meter Stack Module G A M B J I C D E M. Vertical Busbar One-piece vertical busbar from phase balancing joints to meter socket eliminating any chance for hot spots. J. Meter Socket Our unique meter socket base is installed without any fasteners—reducing chances for hot spots, easily replaceable, and improves connection to vertical bus. V1-T5-88 V1-T5-90 V1-T5-95 V1-T5-96 K F H Metering Products Group Metering ● ● ● Eaton’s 1MM stacks are single-phase in, singlephase out design Eaton’s 3MM stacks are three-phase in, singlephase out design Stacks with single-phase horizontal bus are rated 240/120V, single-phase, three-wire. Stacks with three-phase horizontal bus are rated 208Y/120V, threephase, four-wire, but can be used on 240/120V, three-phase, four-wire delta systems ● All three-phase horizontal bus modules have fourwire cross bus, connected A-B phase to vertical bus, readily reconnectable for phase balance on installation Note: Individual sockets cannot be phase balanced, only each stack. ● Short-circuit ratings up to 100,000A rms symmetrical depending upon AIC rating of installed main tenant circuit breakers and main device ● ● ● ● Main tenant feeders can exit bottom or back. Knockouts are available at all exit locations If being used in outdoor application and exiting the top, mount Myer type hubs on rainproof cap Provision for two-pole breaker (plug-on type for 125A sockets and bolt-on type for 200A sockets)— circuit breakers not included Mechanically and electrically built to bolt-up with main service modules and commercial modular metering stacks ● ● ● ● 5.10 Aluminum or copper bus 800 or 1200A horizontal bus All 3MM stacks include fifth jaw at 9 o’clock position All 1MM stacks do not include fifth jaw. Order 1MM5JK if needed 5 5 5 5 5 5 5 5 5 Catalog Number Selection 5 1 MM 4 12 R 5 12 C 5 Phases 1 = Single-phase 3 = Three-phase Type of Metering MM = Multiple metering Number of Meters 2, 3, 4, 5 or 6 Blank = Accessory Ampere Rating 12 = 125A 20 = 200A Blank = Accessory Enclosure R = Outdoor Blank = Indoor Options Blank = Ring RL = Ringless RLB = Ringless with horn bypass WB = Wall bracket (accessory) BSK = Bussed spacer (accessory) EB12 = 12-inch (304.8 mm) elbow (accessory) EB16 = 16-inch (406.4 mm) elbow (accessory) Bus Type Blank = Aluminum C = Copper 5 5 5 5 Bus Amperes 12 = 200A horizontal bus (3MM units only) Blank = Standard 800A bus 5 5 When Ordering: 1. Determine catalog number of Main Service Module. 5 2. Determine catalog number of Meter Stack (Residential or Commercial). 5 3. Find quantity and catalog numbers for tenant circuit breakers (found on Page V1-T5-125 or V1-T5-135). Order one breaker per socket. 5 4. If any accessories are needed, order from Pages V1-T5-136 and V1-T5-137. 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-117 5.10 5 5 5 Metering Products Group Metering Product Selection 1MM and 3MM Metering Stack Modules 800A Horizontal Aluminum Bus—Standard Offering Amperes Per Meter Socket 5 5 Number of Meter Sockets Bus Ampacity Enclosure Type 1 Main Tenant Breaker Type (For Specific Catalog Numbers, Refer to Page V1-T5-125) Single-Phase In, Single-Phase Out Three-Phase In, Single-Phase Out Single-Phase Horizontal Bus (Three Horizontal Busbars— A, B and Neutral) 2 Three-Phase Horizontal Bus (Four Horizontal Busbars— A, B, C and Neutral) Catalog Number Catalog Number Use three-phase 3MM212R Ring Style Meter Socket Covers 125 3 5 5 5 200 5 5 5 5 24 800 Indoor/outdoor 34 800 Indoor/outdoor 4 800 Indoor/outdoor Plug-on type BR2_ BRH2_ BRHH2_ 1MM312R 3MM312R 1MM412R 3MM412R 5 800 Indoor/outdoor 1MM512R 3MM512R 6 800 Indoor/outdoor 1MM612R 3MM612R 2 800 Outdoor Use three-phase 3MM220R 3 800 Outdoor 1MM320R 3MM320R 4 800 Outdoor 5 800 Outdoor Bolt-on type CCV2_X CCVH2_X CVS2_XMM CV2_XMM CVH2_XMM 1MM420R 3MM420R 1MM520R 6 3MM520R 5 Ringless Style Meter Socket Covers 125 Use three-phase 3MM212RRL 1MM312RRL 3MM312RRL 1MM412RRL 3MM412RRL Outdoor 1MM512RRL 3MM512RRL 800 Outdoor 1MM612RRL 3MM612RRL 800 Outdoor Use three-phase 3MM220RRL 1MM320RRL 3MM320RRL 2 800 Outdoor 3 800 Outdoor 5 4 800 Outdoor 5 800 5 6 2 5 200 5 5 3 800 Outdoor 4 800 Outdoor 5 5 800 Outdoor Plug-on type BR2_ BRH2_ BRHH2_ Bolt-on type CCV2_X CCVH2_X CVS2_XMM CV2_XMM CVH2_XMM 1MM420RRL 1MM520RRL 3MM420RRL 6 3MM520RRL 5 Ringless Style Covers with Horn Bypass 125 5 5 5 200 5 5 5 2 800 Outdoor 3 800 Outdoor 4 800 Outdoor Plug-on type BR2_ BRH2_ BRHH2_ Use three-phase 3MM212RRLB 1MM312RRLB 3MM312RRLB 1MM412RRLB 3MM412RRLB 5 800 Outdoor 1MM512RRLB 3MM512RRLB 6 800 Outdoor 1MM612RRLB 3MM612RRLB 2 800 Outdoor 3 800 Outdoor 4 800 Outdoor 5 800 Outdoor Bolt-on type CCV2_X CCVH2_X CVS2_XMM CV2_XMM CVH2_XMM Use three-phase 3MM220RRLB 1MM320RRLB 3MM320RRLB 1MM420RRLB 3MM420RRLB 1MM520RRLB 6 3MM520RRLB 5 Notes 1 For indoor applications where a top endwall with knockouts is needed, order one of part number MM12N1WLK for each 125A stack or MM20N1WLK for each 200A stack. 2 1MM units do not come with 5th jaw. 3 To change in field from ring to ringless—order 1MMRC125. 4 To change in field from ring to ringless, the top socket in 125A, two- and three-high stacks use 1MMRC125T. Top socket only—other sockets see 3. 5 To change in field from ring to ringless—order 1MMRC200. 6 Check with local utility for height requirements or restrictions. 5 5 5 5 5 5 5 V1-T5-118 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 5.10 Metering Products Group Metering 1MM and 3MM Metering Stack Modules 800A Horizontal Copper Bus—Premium Offering Amperes Per Meter Socket Number of Meter Sockets Bus Ampacity Enclosure Type 1 Main Tenant Breaker Type (For Specific Catalog Numbers, Refer to Page V1-T5-125) 5 Single-Phase In, Single-Phase Out Three-Phase In, Single-Phase Out Single-Phase Horizontal Bus (Three Horizontal Busbars— A, B, C and Neutral) 2 Three-Phase Horizontal Bus (Four Horizontal Busbars— A, B, C and Neutral) Catalog Number Catalog Number Use three-phase 3MM212RC 200 5 24 800 Outdoor 34 800 Outdoor 4 800 Outdoor 5 800 6 2 Plug-on type BR2_ BRH2_ BRHH2_ 1MM312RC 3MM312RC 1MM412RC 3MM412RC Outdoor 1MM512RC 3MM512RC 800 Outdoor 1MM612RC 3MM612RC 800 Outdoor Use three-phase 3MM220RC 3 800 Outdoor 4 800 Outdoor 5 800 Outdoor Bolt-on type CCV2_X CCVH2_X CVS2_XMM CV2_XMM CVH2_XMM 1MM320RC 3MM320RC 1MM420RC 3MM420RC 1MM520RC 6 3MM520RC 5 Use three-phase 3MM212RRLC 5 5 5 5 5 5 Ringless Style Meter Socket Covers 125 200 2 800 Outdoor 3 800 Outdoor 4 800 Outdoor Plug-on type BR2_ BRH2_ BRHH2_ 1MM312RRLC 3MM312RRLC 1MM412RRLC 3MM412RRLC 5 800 Outdoor 1MM512RRLC 3MM512RRLC 6 800 Outdoor 1MM612RRLC 3MM612RRLC 2 800 Outdoor Use three-phase 3MM220RRLC 3 800 Outdoor 4 800 Outdoor 5 800 Outdoor Bolt-on type CCV2_X CCVH2_X CVS2_XMM CV2_XMM CVH2_XMM 5 5 5 5 1MM320RRLC 3MM320RRLC 1MM420RRLC 3MM420RRLC 1MM520RRLC 6 3MM520RRLC 5 5 Use three-phase 3MM212RRLBC 5 Ringless Style Covers with Horn Bypass 125 200 2 800 Outdoor 3 800 Outdoor 4 800 Outdoor Plug-on type BR2_ BRH2_ BRHH2_ 1MM312RRLBC 3MM312RRLBC 1MM412RRLBC 3MM412RRLBC 5 800 Outdoor 1MM512RRLBC 3MM512RRLBC 6 800 Outdoor 1MM612RRLBC 3MM612RRLBC 2 800 Outdoor Use three-phase 3MM220RRLBC 3 800 Outdoor 1MM320RRLBC 3MM320RRLBC 4 800 Outdoor 1MM420RRLBC 3MM420RRLBC 5 800 Outdoor 1MM520RRLBC 6 3MM520RRLBC 5 Bolt-on type CCV2_X CCVH2_X CVS2_XMM CV2_XMM CVH2_XMM 5 5 Ring Style Meter Socket Covers 125 3 5 5 5 5 5 5 5 Notes 1 For indoor applications where a top endwall with knockouts is needed, order (1) of part number MM12N1WLK for each 125A stack or MM20N1WLK for each 200A stack. 2 1MM units do not come with 5th jaw. 3 To change in field from ring to ringless—order 1MMRC125. 4 To change in field from ring to ringless, the top socket in 125A, two- and three-high stacks use 1MMRC125T. Top socket only—other sockets see 3. 5 To change in field from ring to ringless—order 1MMRC200. 6 Check with local utility for height requirements or restrictions. 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-119 5.10 5 5 1MM and 3MM Metering Stack Modules Metering Products Group Metering 1200A Horizontal Aluminum Bus—Standard Offering Three-Phase In, Single-Phase Out Amperes Per Meter Socket 5 Number of Meter Sockets Bus Ampacity Enclosure Type 1 Main Tenant Breaker Type (For Specific Catalog Numbers, Refer to Page V1-T5-116) Three-Phase Horizontal Bus (Four Horizontal Busbars— A, B, C and Neutral) Catalog Number Ring Style Meter Socket Covers 5 125 2 5 5 23 1200 Indoor/outdoor 33 1200 Indoor/outdoor 4 1200 Indoor/outdoor 5 1200 Indoor/outdoor 6 1200 Indoor/outdoor 2 1200 Outdoor 5 3 1200 Outdoor 4 1200 Outdoor 5 5 1200 Indoor/outdoor 5 200 4 Plug-on type BR2_ BRH2_ BRHH2_ 3MM212R12 3MM312R12 3MM412R12 3MM512R12 3MM612R12 Bolt-on type CCV2_X CCVH2_X CVS2_XMM CV2_XMM CVH2_XMM 3MM220R12 3MM320R12 3MM420R12 3MM520R12 Ringless Style Meter Socket Covers (5th Jaw at 9 o’Clock Standard—Field Adjustable to 3 or 6 o’Clock) 5 125 2 1200 Outdoor 5 3 1200 Outdoor 4 1200 Outdoor 5 5 1200 Outdoor 3MM512R12RL 6 1200 Outdoor 3MM612R12RL 5 200 2 1200 Outdoor 5 3 1200 Outdoor 4 1200 Outdoor 5 5 1200 Outdoor Plug-on type BR2_ BRH2_ BRHH2_ Bolt-on type CCV2_X CCVH2_X CVS2_XMM CV2_XMM CVH2_XMM 3MM212R12RL 3MM312R12RL 3MM412R12RL 3MM220R12RL 3MM320R12RL 3MM420R12RL 3MM520R12RL Ringless Style Covers with Horn Bypass (5th Jaw at 9 o’Clock Standard—Field Adjustable to 3 or 6 o’Clock) 5 125 2 1200 Outdoor 5 3 1200 Outdoor 4 1200 Outdoor 5 5 1200 Outdoor 6 1200 Outdoor 2 1200 Outdoor 3 1200 Outdoor 4 1200 Outdoor 5 1200 Outdoor 5 200 5 5 Plug-on type BR2_ BRH2_ BRHH2_ 3MM212R12RLB 3MM312R12RLB 3MM412R12RLB 3MM512R12RLB 3MM612R12RLB Bolt-on type CCV2_X CCVH2_X CVS2_XMM CV2_XMM CVH2_XMM 3MM220R12RLB 3MM320R12RLB 3MM420R12RLB 3MM520R12RLB Notes 1 For indoor applications where a top endwall with knockouts is needed, order (one) of part number MM12N1WLK for each 125A stack or MM20N1WLK for each 200A stack. 2 To change in field from ring to ringless—order 1MMRC125. 3 To change in field from ring to ringless, the top socket in 125A, two- and three-high stacks use 1MMRC125T. Top socket only—other sockets see 2. 4 To change in field from ring to ringless—order 1MMRC200. 5 5 5 5 5 5 5 5 5 V1-T5-120 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Group Metering 1MM and 3MM Metering Stack Modules 5.10 1200A Horizontal Copper Bus—Premium Offering Three-Phase In, Single-Phase Out Amperes Per Meter Socket Number of Meter Sockets Bus Ampacity Enclosure Type 1 Main Tenant Breaker Type (For Specific Catalog Numbers, Refer to Page V1-T5-116) 5 Three-Phase Horizontal Bus (Four Horizontal Busbars— A, B, C and Neutral) 5 Catalog Number Ring Style Meter Socket Covers 125 2 200 4 23 1200 Indoor/outdoor 33 1200 Indoor/outdoor 4 1200 Indoor/outdoor 5 1200 Indoor/outdoor 6 1200 Indoor/outdoor 2 1200 Outdoor 3 1200 Outdoor 4 1200 Outdoor 5 1200 Outdoor Plug-on type BR2_ BRH2_ BRHH2_ 5 3MM212R12C 3MM312R12C 5 3MM412R12C 3MM512R12C 5 3MM612R12C Bolt-on type CCV2_X CCVH2_X CVS2_XMM CV2_XMM CVH2_XMM 3MM220R12C 5 3MM320R12C 3MM420R12C 5 3MM520R12C 5 Ringless Style Meter Socket Covers (5th Jaw at 9 o’Clock Standard—Field Adjustable to 3 or 6 o’Clock) 125 200 2 1200 Outdoor 3 1200 Outdoor 4 1200 Outdoor 5 1200 Outdoor 3MM512R12RLC 6 1200 Outdoor 3MM612R12RLC 2 1200 Outdoor 3 1200 Outdoor 4 1200 Outdoor 5 1200 Outdoor Plug-on type BR2_ BRH2_ BRHH2_ Bolt-on type CCV2_X CCVH2_X CVS2_XMM CV2_XMM CVH2_XMM 3MM212R12RLC 5 3MM312R12RLC 3MM412R12RLC 5 5 3MM220R12RLC 3MM320R12RLC 5 3MM420R12RLC 3MM520R12RLC 5 Ringless Style Covers with Horn Bypass (5th Jaw at 9 o’Clock Standard—Field Adjustable to 3 or 6 o’Clock) 125 200 2 1200 Outdoor 3 1200 Outdoor 4 1200 Outdoor 5 1200 Outdoor 6 1200 Outdoor 2 1200 Outdoor 3 1200 Outdoor 4 1200 Outdoor 5 1200 Outdoor Plug-on type BR2_ BRH2_ BRHH2_ 5 3MM212R12RLBC 3MM312R12RLBC 5 3MM412R12RLBC 3MM512R12RLBC 5 3MM612R12RLBC Bolt-on type CCV2_X CCVH2_X CVS2_XMM CV2_XMM CVH2_XMM 5 3MM220R12RLBC 5 3MM320R12RLBC 3MM420R12RLBC 5 3MM520R12RLBC 5 Technical Data and Specifications 5 Wire Sizes—Neutral and Ground Lugs ● Each stack includes a neutral and ground bar ● If an extra ground bar is needed, order 1MMGBK 5 5 Wire Sizes—Neutral and Ground Lugs Lugs in Meter Socket Modules Wire Size, Al/Cu 5 Branch neutral—125A socket module #6–2/0 kcmil Branch neutral—200A socket module #1/0–300 kcmil 5 Equipment ground bar—125A socket module #14–#2 kcmil Equipment ground bar—200A socket module #14–2/0 kcmil Optional ground bar (1MMGBK) #6–2/0 kcmil 5 5 Notes 1 For indoor applications where a top endwall with knockouts is needed, order (one) of part number MM12N1WLK for each 125A stack or MM20N1WLK for each 200A stack. 2 To change in field from ring to ringless—order 1MMRC125. 3 To change in field from ring to ringless, the top socket in 125A, two- and three-high stacks use 1MMRC125T. Top socket only—other sockets see 2. 4 To change in field from ring to ringless—order 1MMRC200. Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 5 5 5 V1-T5-121 5.10 Group Metering Dimensions Approximate Dimensions in Inches (mm) 5 Modular Metering Stacks—Aluminum and Copper 5 1MM, 3MM, 125 Amperes 12.26 (311.4) 2.00 (50.8) TYP. 12.26 (311.4) 30.60 (777.2) 9.00 (228.6) 9.00 (228.6) 9.00 (228.6) 9.00 (228.6) 30.60 (777.2) 3.07 (78.0) 4 Meter Device 2, 3 Meter Device 5 Meter Device 5 5 Tangential K.O.'s 3/4, 1, 1-1/4, 1-1/2 6.06 (153.9) 5 2.83 (71.9) 5 2.83 (71.9) 5 5 6.62 (168.1) 2.83 (71.9) "Z" "Y" "X" 5 5 2.33 (59.1) 5 2.83 (71.9) 2.83 (71.9) 12.13 (308.1) 5 5 5 "Z" = C OF 1-1/2" Ring "Y" = C OF 1-1/4" Ring "X" = C OF 3/4" & 1" Ring L L L 5 2.83 (71.9) 0.125 (3.2) Top End & Bottom End View for NEMA 1; Bottom End View for NEMA 3R Note: Dimensions Apply to 800 and 1200 Ampere Horizontal Bus. 5 V1-T5-122 9.00 (228.6) To C L of Main Busbar 9.00 (228.6) 9.00 (228.6) To C L of Main Busbar 9.00 (228.6) (6) KO for 1, 1-2/4 1-1/2 Conduit 9.00 (228.6) 48.50 (1231.9) 5 7.01 (178.0) 12.60 (320.3) 5 A 30.0 (777.2) 5 41.80 (1061.7) 12.61 (320.2) 5 21.65 (550.0) 5 CL Meter to CL Rail Mounting Screw 5 To CL of Wall Mtg. Screw 5 34.25 (870.0) 5 12.26 (311.4) 9.00 (228.6) This Bus Omitted On 1 — PH Units 9.00 (228.6) 5 57.50 (1460.5) 9.00 (228.6) 12.26 (311.4) 12.60 (320.0) 5 66.50 (1689.1) 9.00 (228.6) 5 12.60 (320.0) 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 6 Meter Device A 30.60 (777.2) To C L of Main Busbar 5 To C L of Main Busbar 5 Metering Products 5.10 Metering Products Group Metering Approximate Dimensions in Inches (mm) 5 Modular Metering Stacks—Aluminum and Copper 5 1MM, 3MM, 200 Amperes 5 13.50 (342.9) 5 1.70 (43.2) TYP. 5 64.50 (1638.3) 7.01 (178.1) (4) KO For 1, 1-1/4, 1-1/2, 2 Conduit 12.12 (307.8) 5 12.12 (307.8) 5 5 30.55 (776.0) To C L of Main Busbar To C L of Main Busbar 5 12.12 (307.8) 12.12 (307.8) 12.12 (307.8) CL Meter to CL Rail Mtg. Screw This Bus Omitted on 1-PH Devices 30.55 (776.0) 18.42 (467.9) 34.25 (870.0) To L C of Wall Rail Mtg. Screw 15.82 (401.8) Circuit Breaker Covers Omitted On NEMA 1 Devices 18.42 (467.9) 52.35 (1329.7) 5 5 5 5 5 1.75 TYP. (44.5) 2, 3 Meter Device 5 5 4 Meter Device 5 5 13.36 (339.3) 6.59 (167.4) 0.12 (3.0) 5 3.38 (85.9) 5 3.00 (76.2) 5 1.76 (44.7) 6.62 (168.1) 5 5 (6) Cocentric K.O.'s 1", 1-1/4", 1-1/2", 2" 3.29 (83.6) 3.29 (83.6) 1.75 (44.5) 5 5 3.29 (83.6) 5 Bottom View 5 Note: Dimensions Apply to 800 and 1200 Ampere Horizontal Bus. 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-123 5.10 Metering Products Group Metering 5 Approximate Dimensions in Inches (mm) 5 5-High, 200 Amperes, 1MM and 3MM Metering 5 1.70 (43.2) 6.87 (174.5) Typ. 5 13.50 (342.9) 5 5 5 12.13 (308.1) 5 5 12.13 (308.1) 5 5 74.96 (1904.0) 12.13 5 (308.1) 5 5 5 5 5 12.13 (308.1) 33.27 (845.1) Typ. to CL of Wall Mtg. Screw 28.88 to CL of Main Busbar 2.74 (69.6) 3.85 (97.8) 5 5 0.45 (11.4) Typ. 5 5 1.87 (47.5) 16.76 (425.7) (5) Concentric K.O.'s 1", 1-1/4", 1-1/2", 2" 1.75 (44.5) 1.61 3.21 (40.9) (81.5) 3.21 (81.5) 3.21 (81.5) Residential Device 13.36 (339.3) 5 0.12 (3.0) 5 6.59 (167.4) 3.38 (85.9) 1.76 (44.7) 6.62 (168.1) 5 5 (6) Cocentric K.O.'s 1", 1-1/4", 1-1/2", 2" 5 5 3.29 (83.6) 3.29 (83.6) 1.75 (44.5) 3.29 (83.6) 5 5 3.00 (76.2) Bottom View Note: The Bussed meter stack device shown on the far right of the figure, must be used on Mains with Busway connections, found on Pages V1-T5-109 and V1-T5-113. Please contact factory for catalog numbers associated with Bussed meter stack devices. 5 V1-T5-124 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Group Metering 5.10 Contents 1MM and 3MM Metering Circuit Breakers Description Page Systems for Residential and Commercial Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type CCV 120/240V Tenant Main Circuit Breaker . Type CV 120/240V Tenant Main Circuit Breaker . . Meter Packs—1MP, 1MM and 3MM Main Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . . Main Service Modules . . . . . . . . . . . . . . . . . . . . . Surge Metering . . . . . . . . . . . . . . . . . . . . . . . . . . . Residential Meter Stacks. . . . . . . . . . . . . . . . . . . . 1MP, 1MM and 3MM Main Tenant Circuit Breakers Phase Balanced Stack . . . . . . . . . . . . . . . . . . . . . . Commercial Meter Stack Modules . . . . . . . . . . . . 35MM, 37MM, 35SS and 37SS Main Tenant Circuit Breakers . . . . . . . . . . . . . . . CV2200 V1-T5-88 V1-T5-90 V1-T5-95 V1-T5-96 V1-T5-98 V1-T5-101 V1-T5-115 V1-T5-116 V1-T5-126 V1-T5-127 V1-T5-134 5 5 5 5 5 5 5 5 5 5 1MP, 1MM and 3MM Main Tenant Circuit Breakers 5 Product Description 5 Specific main tenant circuit breakers that are to be used in meter packs (1MP), residential meter stacks (1MM) and three-phase in single-phase out meter stacks (3MM). 5 5 5 5 Product Selection Description 10 kAIC 22 kAIC 25 kAIC 42 kAIC 65 kAIC 100 kAIC Number of Poles Catalog Number 1 Catalog Number Catalog Number 1234 Catalog Number 234 Catalog Number 234 Catalog Number 234 2 60 BR260 BRH260 — BRHH260 — — 2 70 BR270 BRH270 — BRHH270 — — 2 80 BR280 BRH280 — BRHH280 — — 2 90 BR290 BRH290 — BRHH290 — — 2 100 BR2100 BRH2100 — BRHH2100 — — 2 110 BR2110 BRH2110 — BRHH2110 — — 2 125 BR2125 BRH2125 — BRHH2125 — — 5 5 5 5 5 Bolt-On Type Bolt-on type circuit breakers used with 2 1MP, 1MM, and 3MM 200A modular 2 metering stacks 2 60 — — CVS2060XMM CVS2060XMM CV2060XMM CVH2060XMM 70 — — CVS2070XMM CVS2070XMM CV2070XMM CVH2070XMM 80 — — CVS2080XMM CVS2080XMM CV2080XMM CVH2080XMM 2 90 — — CVS2090XMM CVS2090XMM CV2090XMM CVH2090XMM 2 100 CCV2100X — CCVH2100X CVS2100XMM CV2100XMM CVH2100XMM 2 125 CCV2125X — CCVH2125X CVS2125XMM CV2125XMM CVH2125XMM 2 150 CCV2150X — CCVH2150X CVS2150XMM CV2150XMM CVH2150XMM 2 175 CCV2175X — CCVH2175X CVS2175XMM CV2175XMM CVH2175XMM 2 200 CCV2200X — CCVH2200X CVS2200XMM CV2200XMM CVH2200XMM Notes 1 #2–300 kcmil wire size range for CCV and CCVH tenant main circuit breakers. 2 “MM” suffix indicates mounting hardware kit is included as standard with tenant main breaker. 3 1MMCBK replacement mounting hardware kit. One kit is needed per breaker. Mounting hardware kit ships standard with breaker “MM” suffix offering. 4 #6–4/0 kcmil wire size range for CVS, CV and CVH tenant main circuit breakers. If #2–300 kcmil is needed, order 2TA225CVK. One kit needed per breaker. Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 5 5 Plug-On Type Plug-on type circuit breakers used with 1MP, 1MM, and 3MM 125A modular metering stacks 5 Main Tenant Circuit Breaker Ampere Rating 5 5 5 5 5 5 V1-T5-125 5.10 Metering Products Group Metering Contents 5 Description 5 5 5 5 5 5 5 5 5 5 Phase Balanced Stack 5 Product Description Features Eaton’s Phase Balanced Stack allows for a complete phase balanced metering lineup using fewer stacks. With today’s electrical rooms becoming smaller, the need is greater than ever to offer space-saving metering products while providing a fully phase balanced system. The new phase balanced stack is the answer. ● 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Page Systems for Residential and Commercial Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type CCV 120/240V Tenant Main Circuit Breaker . Type CV 120/240V Tenant Main Circuit Breaker . . Meter Packs—1MP, 1MM and 3MM Main Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . Main Service Modules . . . . . . . . . . . . . . . . . . . . . Surge Metering. . . . . . . . . . . . . . . . . . . . . . . . . . . Residential Meter Stacks . . . . . . . . . . . . . . . . . . . 1MP, 1MM and 3MM Main Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . Phase Balanced Stack Commercial Meter Stack Modules . . . . . . . . . . . . 35MM, 37MM, 35SS and 37SS Main Tenant Circuit Breakers . . . . . . . . . . . . . . . Today, achieving a phase balanced system when connected to a 208Y/120 Vac three-phase, four-wire system may require one or two additional 3MM meter modules. Standard 3MM meter stacks come factory connected to phases A and B. The new phase balanced stacks connect the two bottom meters to phases B and C and the top two or three meters to phases A and C. Using these new stacks with the AB phased 3MM metering, phase balancing is accomplished, and more compact than before. ● ● ● ● ● Available in four- and five-high configurations at 125A 200A stacks available Available with 800A aluminum bus and 1200A copper bus Ring, ringless, ringless with horn bypass available Outdoor enclosure Dimensions same as existing 125A, three-phase meter stacks V1-T5-98 V1-T5-101 V1-T5-115 V1-T5-116 V1-T5-125 V1-T5-127 V1-T5-134 Product Selection Ordering Information ● Check with local utility for height restrictions ● Items loaded in VISTA ● If you have questions, please contact the Technical Resource Center 1-800-356-1243, option 3 Phase Balanced Stack Amperes Per Meter Socket Bus Ampacity Meter Socket Cover Catalog Number 125 800 Ring 3MM412RACBC 125 800 Ring 3MM512RACBC 125 800 Ringless 3MM412RRLACBC 125 800 Ringless 3MM512RRLACBC 125 800 Ringless horn bypass 3MM412RRLBACBC 125 800 Ringless horn bypass 3MM512RRLBACBC 125 1200 Ring 3MM412R2ACBC 125 1200 Ring 3MM512R2ACBC 125 1200 Ringless 3MM412R2RLACBC 125 1200 Ringless 3MM512R2RLACBC 125 1200 Ringless horn bypass 3MM412R2RLBACBC 125 1200 Ringless horn bypass 3MM512R2RLBACBC Note: Local codes and utility requirements still apply. The phase balance stacks are not suitable for changing in the field. 5 5 5 V1-T5-126 V1-T5-88 V1-T5-90 V1-T5-95 V1-T5-96 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Group Metering Commercial Meter Stack Modules (35MM, 37MM, 35SS and 37SS) 5.10 Contents Description 35MM, 37MM, 35SS and 37SS Page Systems for Residential and Commercial Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type CCV 120/240V Tenant Main Circuit Breaker . Type CV 120/240V Tenant Main Circuit Breaker . . Meter Packs—1MP, 1MM and 3MM Main Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . . Main Service Modules . . . . . . . . . . . . . . . . . . . . . Surge Metering . . . . . . . . . . . . . . . . . . . . . . . . . . . Residential Meter Stacks. . . . . . . . . . . . . . . . . . . . 1MP, 1MM and 3MM Main Tenant Circuit Breakers. . . . . . . . . . . . . . . . . . . . . . . . . . Phase Balanced Stack . . . . . . . . . . . . . . . . . . . . . . Commercial Meter Stack Modules 35MM, 37MM, 35SS and 37SS Main Tenant Circuit Breakers . . . . . . . . . . . . . . . V1-T5-88 V1-T5-90 V1-T5-95 V1-T5-96 V1-T5-98 V1-T5-101 V1-T5-115 V1-T5-116 V1-T5-125 V1-T5-126 5 5 5 5 5 5 5 5 5 V1-T5-134 5 Commercial Meter Stack Modules 5 Product Description 5 ● ● ● ● Heavy-duty lever bypass socket design Single-phase or threephase designs (35 = singlephase, 37 = three-phase) Provision for two-pole or three-pole main tenant breakers Phase balance kits are included with three-high and four-high modules Features, Benefits and Functions A. End Walls The top cap is removable and does not contain knockouts, so contractors can position and punch holes where they need them. There are numerous KOs in the back and bottom for flexibility. E. Barrier A solid metal barrier separates the meter socket section from the tenant breaker in the wireway section. The unmetered vertical bus is enclosed to guard against power theft. I. Indoor/Outdoor Construction Raintight caps, meter covers and lockable raintight tenant breaker covers make it convenient for you to use any of our modules on either NEMA 1 or NEMA 3R applications. B. Ground Bars The factory-installed equipment ground bars are provided in both the top and bottom gutters. F. Neutral Assembly Located in the wireway of each module, the assembly permits convenient termination of the neutral conductors. J. Mounting Rail Rear mounting rail and wall hanger speed and simplify installation. (Mounting rail not shown.) C. Meter Socket The 5-jaw meter socket and 7-jaw meter socket includes a built-in manual bypass and jaw release. The ground wire is factory connected in both 35MM and 37MM modules. D. Separate Wireway Cover If work on the breakers or cables is necessary, it can be accomplished without disturbing the meters or meter covers, thanks to a separate cover that allows easy access to the module’s main tenant breaker and wireway section. (Not shown.) G. Enclosed Horizontal Bus Non-removable metal barrier encloses 1200A horizontal bus when passing through the tenant breaker section for added security. H. Tenant Breaker Range All modules accept 15–225A bolt-on breakers in various AIC ratings. The CHH_X breaker carries a UL listed series rating of 100,000A, which allows you to use standard 10 kAIC breakers in downstream loadcenters and panelboards by Eaton. K. Nameplate and Ratings The nameplate gives you full rating data: 208Y/120, threephase, four-wire; 240/120, three-phase, four-wire delta (high leg on B-phase); and 240/120 single-phase. (Not shown.) L. Mains and Modules Slip together quickly, smoothly with frontaccessible captive bolts securing the juncture without removing socket interiors or bus access plate. Main bus joint bolts torque to 25 foot pounds. 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-127 5.10 5 Metering Products Group Metering 37MM Meter Stack Module 5 I 5 H 5 E 5 F ● 5 5 ● ● L C G ● 5 5 5 B 5 A 5 5 5 Eaton’s 35MM and 37MM modular metering stacks contain meter sockets with built-in manual bypass and jaw release (Non-EUSERC areas) Eaton’s 35SS and 37SS stacks use meter sockets with test bypass feature (meets EUSERC electrical requirements) All commercial modular metering stacks contain four horizontal cross buses Mechanically and electrically built to bolt-up with main service modules and residential modular metering stacks Catalog Number Selection Commercial Meter Stack Modules 5 3 7 MM 1 40 R 12 40 K C 5 Bus C = Copper Blank = Aluminum 5 5 Phases Three-phase only 5 Type of Metering MM = Commercial metering module SS = Safety socket—EUSERC 5 5 Number of Meters 1, 2, 3 or 4 5 Socket Type K = K Base bolt-on socket Blank = Plug-in type socket Number of Jaws 5 or 7 Enclosure R = NEMA 3R 5 5 Tenant Breakers 40 = 400A included Blank = Ordered separately Socket Amperage 20 = 200A 40 = 400A 12 AB AC BC Bus = 1200A main bus ampacity = Phases A&B—EUSERC = Phases A&C—EUSERC = Phases B&C—EUSERC When Ordering: 1. Determine catalog number of Main Service Module. 5 2. Determine catalog number of Meter Stack (Residential or Commercial). 5 3. Find quantity and catalog numbers for tenant circuit breakers (found on Page V1-T5-134). Order one breaker per socket. 5 4. If any accessories are needed, order from Pages V1-T5-136 and V1-T5-137. 5 5 5 V1-T5-128 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 5.10 Metering Products Group Metering Product Selection 35MM ● Each socket is a 5 terminal block with lever bypass and jaw release ● Ringless covers ● Provision for two-pole main tenant breakers (circuit breakers not included). For circuit breaker catalog numbers, refer to Page V1-T5-134 5 ● Phase balancing kits are included with three-high and four-high modules. Each individual socket can be phase balanced in the field to the desired lines (A-B, B-C or A-C). Comes from factory as A-B ● ● ● Indoor/outdoor construction Main tenant feeders can exit top, bottom or back If being used in outdoor application and exiting the top, mount Myer type hubs on rainproof cap ● ● Short-circuit ratings up to 100A rms symmetrical depending upon the kAIC rating of installed main tenant circuit breakers and main device Non-EUSERC areas 5 5 5 5 5 5 35MM—Single-Phase Commercial Meter Stack Modules (Three-Phase In, Single-Phase Out) Horizontal Bus Ampacity/ Material Number of Jaws Per Meter Socket Main Tenant Breaker Type (Page V1-T5-134) 1 Bolt-on type EHD2_ CCV2_X CCVH2_X CVS2_XMM CV2_XMM CVH2_XMM 5 System Voltage Ampere Rating Per Meter Socket Number of Meter Sockets 120/240V, single-phase, three-wire systems and 208Y/120V network metering (Not suitable for use on three-phase, four-wire delta systems) 225 1 1200 Al 5 1 1200 Cu 5 2 1200 Al 5 2 1200 Cu 5 3 1200 Al 5 3 1200 Cu 5 35MM320R12C 4 1200 Al 5 35MM420R12 400 400 4 1200 Cu 5 1 1200 Al 5 1 1200 Cu 5 5 Catalog Number 5 35MM120R12 35MM120R12C 5 35MM220R12 5 35MM220R12C 35MM320R12 5 5 35MM420R12C 400A K-Frame included 35MM140R1240C 2 5 5 1200 Al 5 1 1200 Cu 5 2 1200 Al 5 2 1200 Cu 5 400 continuous 1 1200 Cu 5 400A L-Frame included 35MM140R1240K 5 400 continuous 1 1200 Cu 5 400A L-Frame included 35MM140HR1240KC 4 5 400A K-Frame included 35MM140HR1240 3 1 400 400A K-Frame included 35MM140R1240 2 35MM140HR1240C 3 35MM240R1240 35MM240R1240C Notes 1 Retrofit tenant circuit breaker mounting kit (37MMRCBK) for installation of Type EHD and CV breakers. Needed only for stacks manufactured prior to February 2013. Order one kit per breaker. 2 Unit is bottom exit only. 3 Rated at 100 kAIC. 4 Rated at 35 kAIC. 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-129 5.10 5 5 5 5 5 Metering Products Group Metering 37MM ● Each socket is a 7 terminal block with lever bypass and jaw release ● Ringless covers ● Provision for three-pole main tenant breakers (circuit breakers not included). For circuit breaker catalog numbers, refer to Page V1-T5-134 ● ● ● Indoor/outdoor construction Main tenant breakers can exit top, bottom or back If being used in outdoor application and exiting the top, mount Myer type hubs on rainproof cap ● ● Short-circuit ratings up to 100A rms symmetrical depending upon the kAIC rating of installed main tenant circuit breakers and main device Non-EUSERC areas 5 5 5 5 37MM—Three-Phase Commercial Meter Stack Modules (Three-Phase In, Three-Phase Out) System Voltage Ampere Rating Per Meter Socket 208Y/120V, three-phase, four-wire 240/120V, three-phase, four-wire delta (B-phase is high leg) 225 Number of Meter Sockets Horizontal Bus Ampacity/ Material Number of Jaws Per Meter Socket 1 Main Tenant Breaker Type 2 (Page V1-T5-134) Bolt-on type EHD3_ CC3_X CVS3_X CV3_X CVH3_X Catalog Number 1 1200 Al 7 1 1200 Cu 7 2 1200 Al 7 5 2 1200 Cu 7 5 3 1200 Al 7 37MM320R12 3 1200 Cu 7 37MM320R12C 4 1200 Al 7 37MM420R12 4 1200 Cu 7 1 1200 Al 7 1 1200 Cu 7 1200 Al 7 5 5 5 400 37MM120R12 37MM120R12C 37MM220R12 37MM220R12C 37MM420R12C 400A K-Frame included 37MM140R12 3 400A K-Frame included 37MM140R1240 4 400A K-Frame included 37MM140HR1240 5 400A K-Frame included 37MM240R1240 37MM140R12C 3 5 400 1 5 1 1200 Cu 7 400 1 1200 Al 7 5 1 1200 Cu 7 400 2 1200 Al 7 5 2 1200 Cu 7 400 continuous 1 1200 Cu 7 37MM140R1240KC 6 5 400A L-Frame included 400 continuous 1 1200 Cu 7 400A L-Frame included 37MM140HR1240KC 7 5 5 5 5 37MM140R1240C 4 37MM140HR1240C 5 37MM240R1240C Notes 1 If a socket in a 37MM meter stack module needs to be single-phase, order 37MM1CK. This will convert the three-phase socket to single-phase. 2 Retrofit tenant circuit breaker mounting kit (37MMRCBK) for installation of Type EHD and CV breakers. Needed only for stacks manufactured prior to February 2013. Order one kit per breaker. 3 320A continuous rated socket with provisions for two main tenant breakers. 4 Unit is bottom exit only. 5 Rated at 100 kAIC. 6 Rated at 25 kAIC. 7 Rated at 35 kAIC. 5 5 5 5 5 5 5 V1-T5-130 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Group Metering 35SS ● Sockets include EUSERC required test-bypassdisconnect feature ● Ring type covers ● Single-phase units have provisions for two-pole main tenant breakers 35SS_ When applying 35SS (single-phase) stacks on 208Y/120V, three-phase, four-wire and 240/120V, three-phase, four-wire delta systems, refer to suffixes for proper phase balancing. Each meter stack module is phase balanced at the plant (A-B, B-C or A-C) and cannot be field modified ● ● ● Indoor/outdoor construction Main tenant breakers can exit top, bottom or back. If being used in outdoor application and exiting the top, mount Myer type hubs on rainproof cap ● 5.10 Short-circuit ratings up to 100A rms symmetrical depending upon the kAIC rating of installed main tenant circuit breakers and main device 5 5 5 5 5 5 35SS—Three-Phase Commercial Meter Stack Modules 5 System Voltage Ampere Rating Per Meter Socket Number of Meter Sockets Horizontal Bus Ampacity/ Material 120/240V, single-phase, three-wire systems and 208Y/120V network metering (Not suitable for use on three-phase, four-wire delta systems) 225 1 1200 Al 5 1200 Cu 5 1200 Al 5 1200 Cu 5 1200 Al 5 1200 Cu 5 35SS120RBCC 2 1200 Al 5 35SS220RAB 2 1200 Cu 5 35SS220RABC 2 1200 Al 5 35SS220RAC 2 1200 Cu 5 35SS220RACC 2 2 3 37SS ● Sockets include EUSERC required test-bypassdisconnect feature ● Ring type covers 5 Number of Jaws Per Meter Socket Main Tenant Breaker Type 1 (Page V1-T5-134) Bolt-on type EHD2_ CCV2_X CCVH2_X CVS2_X CV2_X CVH2_X Catalog Number 35SS120RAB 2 35SS120RABC 2 35SS120RAC 2 35SS120RACC 2 35SS120RBC 2 2 1200 Al 5 35SS220RBC 1200 Cu 5 35SS220RBCC 2 2 1200 Al 5 35SS320RAB 1200 Cu 5 35SS320RABC 2 1200 Al 5 35SS320RAC 2 1200 Cu 5 35SS320RACC 2 2 1200 Al 5 35SS320RBC 1200 Cu 5 35SS320RBCC 2 5 5 5 5 5 5 5 5 5 5 5 Three-phase units have provisions for three-pole main tenant breaker ● ● 5 Aluminum horizontal bus supplied as standard 5 5 37SS—Three-Phase Commercial Meter Stack Modules System Voltage Ampere Rating Per Meter Socket Number of Meter Sockets Horizontal Bus Ampacity/ Material 208Y/120V, three-phase, four-wire 240/120V, three-phase, four-wire delta (B-phase is high leg) 225 1 1200 Al 7 1200 Cu 7 1200 Al 7 1200 Cu 7 1200 Al 7 1200 Cu 7 2 3 Number of Jaws Per Meter Socket Main Tenant Breaker Type 1 (Page V1-T5-134) Bolt-on type EHD3_ CC3_X CVS3_X CV3_X CVH3_X Catalog Number 37SS120R 37SS120RC 37SS220R 37SS220RC 37SS320R 37SS320RC Notes 1 Retrofit tenant circuit breaker mounting kit (37MMRCBK) for installation of Type EHD and CV breakers. Needed only for stacks manufactured prior to February 2013. Order one kit per breaker. 2 Last two digits of catalog number indicate phase balancing (AB indicates all sockets in this stack are connected to phases A and B only). 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-131 5.10 5 Metering Products Group Metering Approximate Dimensions in Inches (mm) 5 Commercial Stacks (35MM and 37MM) 5 35MM and 37MM 35MM140R1240 37MM140R1240 same as below except eliminate top socket. 5 5 5 5 5 14.00 (355.6) Typ. 5 5 52.63 (1336.7) 25.38 (644.5) 52.63 (1336.7) 66.63 (1692.3) 5 5 5 5 5 8.75 (222.3) 8.75 (222.3) 5 18.25 (463.6) 5 18.25 (463.6) 18.25 (463.6) 5 5 5 5 5 5 5 5 5 5 5 5 5 V1-T5-132 8.75 (222.3) 8.75 (222.3) Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 19.25 (489.0) Metering Products Group Metering 5.10 Approximate Dimensions in Inches (mm) 5 Commercial Stacks (35SS and 37SS) 5 35SS and 37SS 21.38 (542.9) 12.00 (304.8) 21.38 (542.9) 12.00 (304.8) 29.38 (746.1) 9.56 (242.9) 19.50 (495.3) 17.75 (450.9) Centerline 19.50 (495.3) of Wall Mounting Screws 25.00 (635.0) 13.50 (342.9) 2.00 (50.8), 2.50 (63.5) 43.00 (1092.2) 5 5 19.50 (495.3) 31.50 (800.1) 47.38 (1203.3) 5 5 68.88 (1749.4) KO 1.50 (38.1) 5 5 62.44 (1585.9) 6.50 (165.1) 6.50 (165.1) 6.50 (165.1) 0.41 Dia. 9.56 (10.3) (242.9) 4-Holes 5 21.38 (542.9) 12.00 (304.8) 9.50 (241.3) 5 5 31.50 (800.1) 5 5 5 5 Wire Seal Slot and Sealing Screw Ribbon Seal or Barrel Lock Hasp 8.75 Bottom (Typ.) 13.56 (222.3) (344.5) Inside 5 3 KOs 1.50 (38.1), 2.00 (50.8), 2.50 (63.5) 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-133 5.10 5 Metering Products Group Metering 35MM, 37MM, 35SS and 37SS Main Tenant Circuit Breakers Description 5 5 5 5 5 5 5 5 CV2200/CV3200 5 5 5 5 5 5 5 5 5 5 Contents Systems for Residential and Commercial Applications . . . . . . . . . . . . . . . . . . . . . . . . . . . . Meter Packs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Type CCV 120/240V Tenant Main Circuit Breaker . Type CV 120/240V Tenant Main Circuit Breaker . . Meter Packs—1MP, 1MM and 3MM Main Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . Main Service Modules . . . . . . . . . . . . . . . . . . . . . Surge Metering. . . . . . . . . . . . . . . . . . . . . . . . . . . Residential Meter Stacks . . . . . . . . . . . . . . . . . . . 1MP, 1MM and 3MM Main Tenant Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . Phase Balanced Stack. . . . . . . . . . . . . . . . . . . . . . Commercial Meter Stack Modules . . . . . . . . . . . . 35MM, 37MM, 35SS and 37SS Main Tenant Circuit Breakers 35MM, 37MM, 35SS and 37SS Main Tenant Circuit Breakers Product Description ● ● ● ● The following breakers are to be used on 35MM, 37MM, 35SS and 37SS modular metering stacks Series rating information available on Pages V1-T5142 through V1-T5-145 Two-pole breakers are 120/240 Vac, field installed Three-pole breakers are 208Y/120 Vac, field installed 5 5 5 5 5 5 5 5 5 5 5 V1-T5-134 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Page V1-T5-88 V1-T5-90 V1-T5-95 V1-T5-96 V1-T5-98 V1-T5-101 V1-T5-115 V1-T5-116 V1-T5-125 V1-T5-126 V1-T5-127 Metering Products Group Metering 5.10 Product Selection 5 5 35MM, 37MM, 35SS and 37SS Main Tenant Circuit Breakers 10 kAIC 25 kAIC 42 kAIC 65 kAIC 100 kAIC Main Tenant Circuit Breaker Ampere Rating 5 Catalog Number Catalog Number 12 Catalog Number 12 Catalog Number 12 Catalog Number 12 5 Bolt-on type circuit breakers used 2 with 35MM and 35SS (single-phase 2 modular metering stacks) 34 2 60 EHD2060 CVS2060XMM CVS2060XMM CV2060XMM CVH2060XMM 70 EHD2070 CVS2070XMM CVS2070XMM CV2070XMM CVH2070XMM 80 EHD2080 CVS2080XMM CVS2080XMM CV2080XMM CVH2080XMM 2 90 EHD2090 CVS2090XMM CVS2090XMM CV2090XMM CVH2090XMM 2 100 CCV2100X CCVH2100X CVS2100XMM CV2100XMM CVH2100XMM 2 125 CCV2125X CCVH2125X CVS2125XMM CV2125XMM CVH2125XMM 2 150 CCV2150X CCVH2150X CVS2150XMM CV2150XMM CVH2150XMM 2 175 CCV2175X CCVH2175X CVS2175XMM CV2175XMM CVH2175XMM 2 200 CCV2200X CCVH2200X CVS2200XMM CV2200XMM CVH2200XMM 2 225 CCV2225X CCVH2225X CVS2225XMM CV2225XMM CVH2225XMM 3 Bolt-on type circuit breakers used with 37MM and 37SS (three-phase 3 34 modular metering stacks) 3 60 EHD3060 CVS3060X CVS3060X CV3060X CVH3060X 70 EHD3070 CVS3070X CVS3070X CV3070X CVH3070X 80 EHD3080 CVS3080X CVS3080X CV3080X CVH3080X 3 90 EHD3090 CVS3090X CVS3090X CV3090X CVH3090X 3 100 CC3100X CVS3100X CVS3100X CV3100X CVH3100X 3 125 CC3125X CVS3125X CVS3125X CV3125X CVH3125X 3 150 CC3150X CVS3150X CVS3150X CV3150X CVH3150X 3 175 CC3175X CVS3175X CVS3175X CV3175X CVH3175X 3 200 CC3200X CVS3200X CVS3200X CV3200X CVH3200X 3 225 CC3225X CVS3225X CVS3225X CV3225X CVH3225X Description Number of Poles Bolt-On Type Bolt-On Type Notes 1 #6–4/0 kcmil wire size range for CVS, CV and CVH tenant main circuit breakers. If #2–300 kcmil is needed, order 2TA225CVK (two-pole) 3TA225CVK (three-pole). One kit is needed per breaker. 2 “MM” suffix provides mounting hardware needed for 1MP, 1MM and 3MM modular metering stacks only. Mounting hardware is not needed for use in 35MM and 35SS modular metering stacks, but is included as standard with breakers. 3 Retrofit tenant circuit breaker mounting kit (37MMRCBK) for installation of Type EHD and CV breakers. Needed only for stacks manufactured prior to February 2013. Order one kit per breaker. 4 Type EHD main tenant circuit breakers are also available from 15 to 50A. 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-135 5.10 5 Metering Products Group Metering Accessories 5 1MP, 1MM and 3MM Modular Metering Stacks 5 Description Application Fifth jaw kit Bolted onto neutral in the 3, 6 or 9 o’clock position. Typically used on network metering systems (three-phase in/single-phase out) or when specified by utility company. 1MM5JK Isolated fifth jaw kit Connects to the neutral with an insolated wire. 1MM5JKOP Manual bypass kit (ring style socket only) For use with 125A sockets only. (Not top socket.) 1MMBPM125 For use with 200A sockets only. (Not top socket.) 1MMBPM200 1MMBPM125T 5 This kit only to be used for top position of two- and three-high 125A 1MM and 3MM stacks and of 2, 5 and six-position 125A 1MP packs. 5 This kit only to be used for top position of 200A two-position 1MP packs. 1MMBPM200T Used only on ringless cover stacks, kits can be installed on 125A or 200A sockets. 1MMBPH 5 Fifth Jaw Kit 5 5 5 Manual Bypass Kit 5 5 5 Horn Bypass Kit Horn bypass 5 5 Note: For 1MP2122RRL use: WCG8HB 1 Meter bypass jumper Installed on 125A or 200A sockets. Jumpers are plugged into jaws. Order Lexan® cover plate with bypass jumpers to prevent access to meter socket once energized. (Not UL listed.) 1MMBPJ Lexan blank cover Circular cover mounted on ring or ringless devices preventing access to meter socket while meter is not in place. Includes four plastic tabs that plug into each jaw. 1MMPCP Same as 1MMPCP minus the tabs located in the back to plug into jaws. This device to be used while meter bypass jumpers are in place (1MMBPJ). 1MMACP Used for 125A stacks. Fits bottom socket only. Kit replaces existing meter cover preventing access to meter socket. Includes hasp for seal. 1MMBC125B Used on 200A stacks. Fits bottom socket only. Kit replaces existing meter cover preventing access to meter socket. Includes hasp for seal. 1MMBC200B 5 5 Lexan Blank Cover 5 5 5 Blank meter socket cover 5 5 5 5 5 Catalog Number Wall Mounting Rail Wall mounting rail Rails are 4 feet (1.2m) in length. Bolted on wall for stacks, packs and mains to be hung. 1MMWB Bussed Spacer Bussed spacer Bussed spacer 1200A 4-inch (101.6 mm). Required when stacks are mounted on right-hand side in EUSERC areas. (copper) 3MMBSK 2 Bus duct riser/ meter center connection Available in 400, 600, 800A main fusible units only. Contact product line for details. — 5 5 5 5 5 Notes 1 WCG8HB only applies to meter packs built prior to 1998. Current meter packs use 1MMBPH. 2 Must be used when mounting MCB main next to an MTB main or another MCB main device. 5 V1-T5-136 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Group Metering 5.10 Accessories for 1MP, 1MM and 3MM Modular Metering Stacks, continued Indoor Corner Elbow Application Indoor corner elbow (copper) 12-inch (304.8 mm) indoor corner elbow, 1200A, three-phase, four-wire for use with 1MM and 3MM only. Do not use with 35MM, 37MM, 35SS or 37SS stacks. 12-inch corner elbow not EUSERC approved. 3MMEB12 Indoor corner elbow (copper) 16-inch (406.4 mm) indoor corner elbow, 1200A, three-phase, four-wire for use with 1MM, 3MM, 35MM, 37MM, 35SS and 37SS. 3MMEB16 Barrier Barrier for individual sockets 1MMBK Meter jumper and cover Combination meter jumper and cover (200A maximum). Used to jumper line and load jaws as well as cover meter socket preventing exposure to current carrying parts. 1MMJCK 125A two-pole lug block assembly. BRSF125 Lug block Standard Sealing Ring Sealing ring Top endwall 5 Catalog Number Description 5 5 5 5 5 5 5 Stainless steel screw type with brass screw 1MMSR1 Standard (included with packs and stacks) 1 1MMSR2 Stainless steel screw type with cast zinc screw 1MMSR4 Aluminum screw type with locking provisions 1MMSR5 125A, NEMA 1 top end wall with knockouts for 1MM, 3MM meter stacks MM12N1WLK 200A, NEMA 1 top end wall for 1MM, 3MM meter stacks MM20N1WLK 5 5 5 5 5 5 5 Note 1 Aluminum Snap Type. 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-137 5.10 5 Metering Products Group Metering Renewal Parts 5 1MP, 1MM and 3MM Replacement Parts 5 Description Application Ringless cover (can install this to go from ring to ringless) Installed on 125A socket for ringless security 1MMRC125 Installed on 200A socket for ringless security 1MMRC200 For use with top position of 125A, two- and three-position,1MM and 3MM stacks and two-, five- and six-position 1MP packs 1MMRC125T Top-position two position IMP 1MMRC200T Installed on 125A socket for ring security 1MMCP1 Installed on 200A socket for ring security 1MMCP2 5 Top socket ring cover 125A 1MMCP1T 5 Top socket ring cover 200A 1MMCP2T 125A cover 1MMBC1 200A cover 1MMBC2 125 and 200A 1MMMS Flat—left side 47-24139A Bump—right side 47-28172-2A 5 Ringless Cover 5 5 5 5 5 Ring Cover Ring cover 5 5 Tenent Breaker Cover 5 Tenant breaker hinged cover 5 5 5 Meter Socket Meter socket 1 Catalog Number 5 5 5 Busbar end cap 5 Main circuit breaker cover kit (black) 5 49-7060 5 5 Notes 1 Meter Packs 1MP2122RRL and 1MP2122RRLB use different meter sockets. See Renewal Parts listing RP.32A.01A.T.E for details. 5 See RP00501001E for a complete Renewal Parts listing. 5 5 5 5 5 V1-T5-138 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Group Metering 5.10 Accessories for 35MM and 37MM Modular Metering Stacks 5 Catalog Number Description Application Wall mounting rail Rails are 4 feet (1.2m) in length. Bolted on wall for stacks, packs and mains to be hung. 1MMWB 5 Indoor corner elbow (copper) 16-inch (406.4 mm) indoor corner elbow, 1200A, three-phase, four-wire for use with 1MM, 3MM, 35MM, 37MM, 35SS and 37SS. 3MMEB16 5 Handle insulator Each meter block includes a lever bypass. This kit includes the sleeve which slides onto the lever handle. 37MMHC 5 Needed when using barrel lock security. 37MMBLK 5 Barrel Lock Bracket Kit Barrel lock bracket kit 5 5 5 Totalizing Jumper Kit Totalizing jumper kit Used if one socket is to meter two tenant feeds. When ordering jumper kit, should also order a plastic cover plate (1MMPCP + IMMJCK) preventing access to live parts on unused socket. 5 37MMTJK 5 5 Type EHD and CV Breaker Retrofit Mounting Kit Type EHD and CV breaker retrofit mounting kit Retrofit mounting hardware for installation of Type EHD and CV breakers in 35MM, 37SS, 37MM and 37SS meter stacks manufactured prior to February 2013. Order one kit per breaker. 5 37MMRCBK 5 5 Type CV Breaker Mounting Kit Type CV breaker mounting kit Replacement Type CV breaker mounting hardware kit. Used in 200A 1MP/1MM/3MM modular metering stacks at 42, 65 and 100 kAIC. 5 1MMCBK 5 5 5 Blank Cover Kit Blank cover kit Kit replaces meter cover preventing access to socket. 37MMCK 1 5 5 37MMCKA 2 5 Three-Phase to Single-Phase Conversion Kit Barrier Barrier for individual sockets 37MMBK Three-Phase to single-phase conversion kit This kit will convert one three-phase meter socket (37MM devices) to a single-phase socket. Only needed if phasing A-C or C-B. If single-phase socket is to be phased A-B, kit is not required for field conversion. (Must use three-phase breaker.) 37MM1CK 5 5 5 5 5 Bus duct riser/meter center connection Available in 400, 600, 800A Main fusible units and 400, 600, 800, 1000, 1200 main circuit breaker. Contact product line for details. — Anti-inversion clip This clip should be inserted into upper right hand jaw of a 320A meter socket. The purpose is prevent a 200A meter from being inserted into a 320A meter socket. 37MMINVCLIP 5 5 5 Notes 1 For all units made 10/2002 and earlier. 2 For all units made after 11/2002. Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 5 V1-T5-139 5.10 5 Metering Products Group Metering Renewal Parts 5 35MM and 37MM Modular Metering Stacks 5 Description Application 35MM replacement meter socket To replace meter socket with lever bypass and jaw release. MSLMSA1 37MM replacement meter socket To replace meter socket with lever bypass and jaw release. MSLMSA2 35SS replacement meter socket To replace meter socket with test bypass disconnect feature MSTMSA1 37SS replacement meter socket To replace meter socket with test bypass disconnect feature MSTMSA2 5 Safety socket meter cover assembly To replace ring type cover over the meter prior to 7/1/02. MSTMCVR1 5 Safety socket meter cover assembly To replace ring type cover over the meter after 7/1/02 MSTMCVR1E 35MM and 37MM meter cover assembly Prior to 12/1/02 37MMSK After 12/1/02 37MMSK1 To replace ringless cover over the meter. Includes New Jersey latch requirement. 37MMSKNJ 5 35MM Replacement Meter Socket 5 Catalog Number 5 5 5 5 37SS Replacement Meter Socket 5 5 5 Meter Cover Assembly 5 5 5 Meter cover assembly with NJ latch 5 5 Tenant breaker hinged cover To replace cover over tenant breakers. 1MMBC2 Busbar end cap Flat—left side 47-24139A Bump—right side 47-28172-2A Main circuit breaker cover/CIT (black) 5 49-7060 Note See RP.32A.01.T.E for a complete Renewal Parts listing. 5 5 5 5 5 5 5 5 5 5 V1-T5-140 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com 5.10 Metering Products Group Metering Technical Data and Specifications 5 Phase Balancing 125 A STACKS N A A A A 5 B B B B 5 C C C C 5 N 5 A B B "Z" Shaped Phase Connector 5 "Z" Shaped Phase Connector FACTORY 125 A A-B PHASING 5 FACTORY 200 A A-B PHASING N N N FIGURE B 5 A A A A 5 B B B B 5 C C C 5 C C "Barrel" Shaped Phase Connector FIELD 125 A A-C PHASING Remove "Z" Phase Jumper from "B" Phase Horizontal Bus Replace with "Barrel" Phase Jumper from kit 99-4184 Supplied with Meter Stack and attach to "C" Phase Bus as shown. Torque to 60 lb-in (6.78 N-M) Retain "Z" Phase Jumper for future use. FIGURE C N A A “Z” Shaped and “Barrel” Shaped Phase Connector 5 "Barrel" Shaped Phase Connector "Barrel" Shaped Phase Connector 16 Total Positions—use (two) five-position and (two) three-position stacks. Phase balance (one) five-position per Figure B (A-C phasing) and (one) five-position per Figure C (C-B phasing). 5 C 5 "Z" Shaped Phase Connector FACTORY 200 A A-C PHASING 5 Remove "Z" Phase Jumper from "B" Phase Horizontal Bus Reattached at "C" Phase Horizontal Bus as Shown. Torque to 60 lb-in (6.78 N-M) 5 5 N N N N 5 A A A A 5 B B B B 5 C C C 5 C C "Barrel" Shaped Phase Connector B C B 5 "Z" Shaped Phase Connector FIELD 125 A C-B PHASING Remove "Barrel" Phase Jumper from "A" Phase Horizontal Bus Reattached at "C" Phase Horizontal Bus as shown. Torque to 60 lb-in (6.78 N-M) "Barrel" Shaped Phase Connector 5 N A Nine Total Positions—use (three) three-position stacks and phase one per Figure B (A-C phasing) and one per Figure C (C-B phasing). "Z" Shaped Phase Connector "Barrel" Shaped Phase Connector N Examples: 19 Total Positions—where four-position maximum height is allowed by utility. Use (one) four-position and (five) three-position stacks. Phase balance (two) threeposition stacks per Figure B (A-C phasing) and (two) three-position stacks per Figure C (C-B phasing). 5 200 A STACKS "Barrel" Shaped Phase Connector FIGURE A Phase Balancing All 3MM meter modules come factory connected to phase A and B, per Figure A. When connected to a 208Y/120 Vac three-phase, four-wire system, field phase balancing of two out of every three stacks is required. One of every three stacks should be phased AC, per Figure B, and one of every three stacks should be phased CB, per Figure C. 5 "Barrel" Shaped Phase Connector 5 "Z" Shaped Phase Connector 5 FACTORY 200 A C-B PHASING Remove "Barrel" Phase Jumper from "A" Phase Horizontal Bus Reattached at "C" Phase Horizontal Bus as shown. Torque to 60 lb-in (6.78 N-M) 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-141 5.10 5 5 5 5 5 5 5 5 5 5 Metering Products Group Metering Series Combination Short-Circuit Ratings When main tenant breakers are installed in Eaton’s modular metering stack per the table on Page V1-T5-143, the branch breakers installed in downstream panel rated 10 kAIC or greater are protected to the listed series AIC rating. Refer to the downstream panel marking for the proper series combination shortcircuit ratings. Series Combination Short-Circuit Ratings The Watt-Hour Meter is not Included in the Short-Circuit Current Rating (Per UL 67). Downstream Panel (Type CH or BR) Main Tenant Breaker Main Modular Service Metering Module Stack Load Side Breakers Replacement or additional breakers shall be of the same manufacture and type, and shall have an interrupting rating equal to or greater than the interrupting rating of any main tenant breaker installed. 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 V1-T5-142 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Metering Products Group Metering 5.10 Series Combination Short-Circuit Ratings—240 Vac 5 Main Module Overcurrent Device Breaker Type or Class Fuse System AIC Rating 120/240 Vac Maximum Meter Module Tenant Feeder Breaker Type 1MM, 3MM, 35MM, 37MM, 35SS, 37SS or Loadcenter Main Breaker Tenant Feeder Breaker ShortCircuit Rating Loadcenter Branch Breaker (Single-, Two- or Three-Pole) None 10,000 None — BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI Without main disconnect. Cable tap box Type 1MTB_, 3MTB_ 10,000 BR_, CC_, BW_, CCV_ 10,000 22,000 BRH_ 22,000 25,000 CSR_, CHH_H2, CCVH_ 25,000 42,000 BRHH_, CHH_H4, CVS_ 42,000 65,000 CV_, KD_, HKD_ 65,000 5 5 5 5 100,000 CHH_, CVH_, KDC_ 100,000 Main switch module Type 1MFS_, 3MFS_ with Class T fuse, 400A maximum 42,000 BRH_ 22,000 CH, CHT, CH3, CH-GFCI Main switch module Type 1MFS_, 3MFS_ with Class T fuse, 600A maximum 100,000 BRH_ 22,000 BD, BR, BRD, BQ, BQC, GFCB Main switch module Type 1MFS_, 3MFS_ with Class T fuse, 1200A maximum 10,000 BR_, CC_, BW_, CCV_ 10,000 BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI 22,000 BRH_ 22,000 25,000 CSR_, CHH_H2, CCVH_ 25,000 42,000 BRHH_, CHH_H4, CVS_ 42,000 65,000 CV_, KD_, HKD_ 65,000 100,000 CHH_, CVH_, KDC_ 100,000 Main switch module Type 1MFS_, 3MFS_ with Class T fuse, 1200A maximum 100,000 BRHH_ 42,000 BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI Main switch module Type 1BPS_, 3BPS_ with Class L fuse, 1200–2000A 10,000 BR_, CC_, BW_, CCV_ 10,000 BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI 22,000 BRH_ 22,000 25,000 CSR_, CHH_H2, CCVH_ 25,000 42,000 BRHH_, CHH_H4, CVS_ 42,000 65,000 CV_, KD_, HKD_ 65,000 100,000 CHH, CVH_, KDC_ 100,000 10,000 BR_, CC_, BW_, CCV_ 10,000 22,000 BRH_ 22,000 25,000 CSR_, CHH_H2, CCVH_ 25,000 Main breaker module Type 1MCB_, 3MCB_ with KD, HKD (400A maximum) LD, HLD (600A maximum) MDL, HMDL (800A maximum) ND, NGS, HND, NGH (1200A maximum) RD, RGH (2000A maximum) 5 5 5 5 5 5 5 5 5 5 42,000 BRHH_, CHH_H4, CVS_ 42,000 65,000 CV_, KD_, HKD_ 65,000 100,000 1 CHH_, CVH_, KDC_ 100,000 5 5 5 5 BD, BR, BRD, BQ, BQC, GFCB, CH, CHT, CH3, CH-GFCI 5 5 5 5 Note 1 100,000A rating with 100,000A rated main. 5 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-143 5.10 Metering Products Group Metering 5 1MP 125A Meter Module This All-in-One Meter Module is UL listed for the short-circuit rating at 240 Vac maximum in rms symmetrical amperes per table below. 5 1MP 125A Meter Module 5 Tenant Breaker Catalog Number Two-Pole 5 5 5 5 5 5 5 5 1MP 200A Meter Module Tenant Breaker Catalog Number Two- or Three-Pole Maximum Ampere Rating UL Listed Series Short-Circuit Rating Maximum Ampere Rating UL Listed Series Short-Circuit Rating CVH_XMM 200 100 kAIC BRHH_____ 125 42 kAIC CV_XMM 200 65 kAIC BRH_____ 125 22 kAIC CVS_XMM 200 42 kAIC BR_____ 125 10 kAIC CCVH_XMM 200 25 kAIC CCV_X 200 10 kAIC When Type BRHH or BRH tenant breakers are installed in this meter module, then Eaton’s breakers rated 10 kAIC or greater installed on the load side of this meter module may be protected for short circuits up to 22 kAIC with Type BRH breakers or 42 kAIC with Type BRHH breakers. When Type CV tenant breakers are installed in this meter module, then breakers rated 10 kAIC or greater installed on the load side of this meter module may be protected for short circuits up to 100 kAIC. See load side breaker panel marking for proper short-circuit current rating. See load side breaker panel marking for proper short-circuit current rating. 1MP 125A Meter Module 1MP 200A Meter Module The Watt-Hour Meter is not Included in the Short-Circuit Current Rating (Per UL 67). 5 5 5 This All-in-One Meter Module is UL listed for the short-circuit rating at 240 Vac maximum in rms symmetrical amperes per table below. All-in-One Meter Module 5 Downstream Panel (Type CH or BR) Tenant Breaker 5 The Watt-Hour Meter is not Included in the Short-Circuit Current Rating (Per UL 67). All-in-One Meter Module Downstream Panel (Type CH or BR) Tenant Breaker Load Side Breakers 5 1MP 200A Meter Module 5 Note: The ratings for both 125 and 200A tenant positions apply to both Type BR and CH loadcenters and 10 kAIC branch breakers. 5 5 5 5 5 5 5 5 5 5 5 5 V1-T5-144 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com Load Side Breakers 5.10 Metering Products Group Metering General When tenant breakers are installed in Eaton’s metering modules per the short-circuit current ratings below, the branch breakers installed in downstream panel rated 10 kAIC or greater are protected to the listed series AIC rating. Refer to the downstream panel marking for the proper series combination short-circuit ratings. These ratings apply to both loadcenter Types BR and CH. The short-circuit rating is limited to the lowest interrupting rating of any tenant breaker installed or to the lowest marked interrupting rating of the main switch, main breaker or main lug modules. Replacement or additional breakers shall be of the same type and manufacturer, and shall have an interrupting rating equal to or greater than the interrupting rating of any tenant breaker presently installed in the meter module. 1MM, 3MM 125A Meter Module When used with main switch, main breaker or main lug modules, this meter module is UL listed for the short-circuit rating at 240 Vac maximum in rms symmetrical amperes per table below. 1MM, 3MM 125A Meter Module Tenant Breaker Catalog Number Two-Pole Amperes Maximum UL Listed Series Short-Circuit Rating BRHH_____ 125 42 kAIC BRH_____ 125 22 kAIC BR_____ 125 10 kAIC When Type BRHH or BRH tenant breakers are installed in this meter module, then breakers rated 10 kAIC or greater installed on the load side of this meter module may be protected for short circuits up to 22 kAIC with Type BRH breakers or 42 kAIC with Type BRHH breakers. 1MM, 3MM, 200A Meter Modules; 35MM, 37MM, 35SS and 37SS 225A Meter Modules When used with main switch, main breaker or main lug modules, these meter modules are UL listed for the short-circuit rating at 240 Vac maximum in rms symmetrical amperes per table below. 5 1MM, 3MM, 200A Meter Modules; 35MM, 37MM, 35SS and 37SS 225A Meter Modules 5 Amperes Maximum Tenant Breaker Catalog Number Two- or Three-Pole 1MM 3MM 200A 35MM, 37MM, 35SS, 37SS UL Listed Series 225A Short-Circuit Rating CVH_XMM 200 225 100 kAIC CV_XMM 200 225 65 kAIC CVS_XMM 200 225 42 kAIC CCVH_X 200 225 25 kAIC CCV_X 200 225 10 kAIC CC_X 200 225 10 kAIC 5 5 1MM, 3MM, 200A Meter Modules; 35MM, 37MM, 35SS and 37SS 225A Meter Modules 5 5 5 5 5 5 The Watt-Hour Meter is not Included in the Short-Circuit Current Rating (Per UL 67). 5 Downstream Panel (Type CH or BR) 5 Main Tenant Breaker 5 5 Load Side Breakers 5 The Watt-Hour Meter is not Included in the Short-Circuit Current Rating (Per UL 67). 5 Downstream Panel (Type CH or BR) 5 Main Tenant Breaker Main Modular Service Metering Module Stack 5 5 See load side breaker panel marking for proper short-circuit current rating. Main Modular Service Metering Module Stack 1MM, 3MM 125A Meter Module 5 5 When Type CV tenant breakers are installed in these meter modules, then Eaton’s breakers rated 10 kAIC or greater installed on the load side of these meter modules may be protected for short circuits up to 100 kAIC. See load side breaker panel marking for proper short-circuit current rating. 5 5 5 Load Side Breakers 5 5 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-145 5.10 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 5 Metering Products Group Metering Ratings A. The assembly shall be rated to withstand mechanical forces exerted during shortcircuit conditions when connected directly to a power source having available fault current [22,000] [42,000] [65,000] [100,000] amperes symmetrical at rated voltage. Construction A. The entire assembly shall be front accessible and shall include [main lugs] [a main disconnect device]. B. Tenant disconnects shall be wired for cold sequence and shall be molded case circuit breakers. C. The meter sockets shall be (ring-) (ringless-) type rated (125A) (200A) (as shown on the plans) and a bypass (shall be) (shall not be) required. If required, the bypass shall be a (slider-) (horn-) (lever-) (disconnect block-) type. The meter sockets and associated branch protective device positions shall be completely prewired and shipped ready for installation of the meters and tenant main breakers. Meter sockets shall include covers with sealing positions. Bus A. All busbars shall be [tinplated aluminum or copper]. Main horizontal busbars shall be mounted with all three phases arranged in the same vertical plane. Bus sizing shall be based on UL standard temperature rise criteria for multiple metering equipment. B. Provide a full capacity neutral bus where a neutral bus is indicated on the drawings. C. All hardware used for busbar connections shall be high-tensile strength, zinc-plated. Provide Belleville-type spring washers for all bus joints. Wiring/Terminations A. [Mechanical-type terminals] [Crimp-type termination provisions] shall be provided for all line terminations suitable for copper or aluminum cable and rated at 75ºC. B. Lugs shall be provided in the incoming line section for connection of the main grounding conductor. Main Circuit Protective Devices A. Main protective devices shall be [molded case circuit breakers] [bolted pressure switches] [quickmake/quick-break fusible switches]. Molded Case Circuit Breakers A. [Main] [Feeder] [All] protective devices shall be molded case circuit breakers with inverse time and instantaneous tripping characteristics. B. Circuit breakers shall be operated by a toggle-type handle and shall have a quick-make/quick-break over-center switching mechanism that is mechanically trip-free. Automatic tripping of the breaker shall be clearly indicated by the handle position. Contacts shall be nonwelding silver alloy and arc extension shall be accomplished by means of DE-ION® arc chutes. C. Circuit breakers shall have a minimum symmetrical interrupting capacity as indicated on the drawings. D. Circuit breakers [250-] [400-] [600-] [1200-] ampere frame and below shall be manufactured by Eaton with thermalmagnetic or electronic trip units having inverse time-current characteristics. E. Circuit breakers shall be UL listed for series application. Bolted Pressure Switches A. Main protective devices shall be bolted pressure contact type and shall be UL listed. B. Fusible switches shall be furnished with Class L fuse clips. Switch contact interrupting capacity shall be 12 times the continuous rating of the switch. C. Fuse access door s hall be mechanically interlocked with the operating handle and shall have provisions for padlocking the switch in the OPEN position. D. The switch shall use a stored energy deadfront operating mechanism compressed and released by the operating handle, to provide quick positive switching action, independent of the operating handle. E. Switches shall be manually operated. Quick-Make/Quick-Break Fusible Switches A. Fusible switches 30A through 1200A frames shall be furnished with 300V Class T-type fuse clips unless otherwise scheduled. B. Switches shall incorporate safety cover interlocks to prevent opening the cover with the switch in the ON position. C. Provide defeater for authorized personnel. 5 V1-T5-146 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com D. Handles shall have provisions for padlocking and shall clearly indicate the ON or OFF position. E. Front cover doors shall be padlockable in the CLOSED position. F. Main protective devices shall be quick-make/ quick-break fusible switches as manufactured by Eaton. Tenant Utility Metering A. For EUSERC serviced areas, meter centers shall incorporate metering sections with tenant feeder circuits using ring-type meter sockets rated [125] [200] amperes to meet local utility and/or customer requirements. B. The self-contained meter sockets shall include a test bypass/disconnect block per EUSERC requirements, – OR– A. For non-EUSERC serviced areas, meter centers shall incorporate metering sections with tenant feeder circuits using [ring-] [ringless-] type meter sockets rated [125] [200] [320] amperes to meet local utility or customer requirements. Provide meter sockets with individual covers having sealing provisions. B. Meter sockets shall have manual bypass and optional internal barriers. Enclosures A. NEMA 1 Enclosure – OR– A. Outdoor NEMA 3R Surface-Mounted Enclosure Finish A. Boxes and trims shall be bonderized and finished with ANSI 61 light gray enamel. 5.10 Metering Products Group Metering Dimensions 5 Approximate Dimensions in Inches (mm) 5 General Layout 5 Minimum and maximum height of single-phase and three-phase meter sockets above typical ground level. 1MM/3MM 200 A 1MM/3MM 200 A 1MM/3MM 125 A 35MM/37MM 225 A Maximum 35MM/37MM 225 A Maximum 35MM/37MM 225 A Maximum 37MM 400 A 35MM/37MM 5 13.50 (342.9) 13.50 (342.9) 12.25 (311.2) 19.25 (488.8) 18.25 (463.6) 18.25 (463.6) 18.25 (463.6) 18.25 (463.6) 5 5 5 5 5 Wall Hanger Screws C L 5 34.25 (870.0) 5 5 Main Device a 5 b 30.14 (765.6) 13.38 (339.7) 31.88 (809.6) 26.00 (660.4) 68.25 (1733.6) 71.00 (1803.4) 30.00 (762.0) 30.00 (762.0) 72.00 (1828.8) 58.00 (1473.2) 44.00 (1117.6) 44.00 (1117.6) 58.00 (1473.2) 44.00 (1117.6) 31.00 (787.4) 5 5 Typical Height Above Ground or Floor Level 5 5 Mounting Features 5 5 5 5 5 5 Mounting Features 5 A standard mounting rail and factory-installed swing away feet, speed up and simplify installation. 5 5 Notes 1 Not a constant value. Dimension changes depending on main device chosen. See Page V1-T5-110 for specific dimensions. 2 Residential device. 5 5 5 5 Volume 1—Residential and Light Commercial CA08100002E—February 2014 www.eaton.com V1-T5-147
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : No Page Count : 147 Create Date : 2014:09:03 17:35:36 Creator : Google Producer : GoogleEXIF Metadata provided by EXIF.tools