Product Detail Manual
104280-Catalog 104280-Catalog 104280-Catalog 783510 Batch7 unilog cesco-content
2014-09-05
: Pdf 102202-Attachment 102202-Attachment 783510 Batch7 unilog
Open the PDF directly: View PDF .
Page Count: 328
Download | |
Open PDF In Browser | View PDF |
COOLING SPECIFIER’S GUIDE EQUIPMENT PROTECTION MCLEAN IS NOW HOFFMAN COOLING VOLUME 3 ADVANCING A HERITAGE OF LEADERSHIP 763.422.2211 763.576.3200 Pentair Equipment Protection is a global leader in safeguarding industrial controls, electrical components, and communications hardware. Its premier brand, Hoffman®, provides a comprehensive range of standard, modified and custom engineered solutions. For more information, visit www.hoffmanonline.com Hoffman is a leading designer and manufacturer of systems to safely and reliably protect the electronic controls and mission critical electrical systems in industrial, data communications, commercial construction and government applications. Our product catalog features the wide array of enclosures, accessories and thermal management products. We have developed significant vertical market expertise to help us understand and develop industry solutions to address your particular circumstances. Our extensive network of North American distributors and our global sales channel can help you obtain the products you need. In addition to our broad line of standard enclosures, Hoffman has the expertise to deliver modified standard enclosures quickly and reliably as well as complicated co-developed and custom solutions. Hoffman maintains a high standard of quality and operates under a global ISO 9000 certificate. We design and test our products in our in-house UL laboratory to ensure they meet stringent quality standards. Hoffman products comply with UL, NEMA, CSA and other international standards. Hoffman Cooling helps create optimal conditions for the reliable operation of electronic and electrical components in manufacturing controls, telecom equipment, data networks, and other vital systems. From standard fan assemblies to air conditioners, to heat exchangers, to integrated cooling enclosures for a variety of applications, Hoffman assures maximum productivity and uptime while protecting the life cycles of controls and equipment. Flawless operation is the expectation of OEM s, engineers, and end-users alike. That’s why choosing the most qualified cooling technology provider reaches far beyond the implications of product performance to include service and support benchmarks. As a premier global provider with decades of experience in cooling industrial automation and electrical components, Hoffman remains unrivaled with an industry-leading portfolio of proven products, pre- and post-sale support, and comprehensive engineering and testing services. For more information about Hoffman Cooling products visit hoffmanonline.com. About Pentair Ltd. Pentair (www.pentair.com) delivers industry-leading products, services and solutions for its customers in diverse needs in water and other fluids, thermal management and equipment protection. With 2012 pro forma revenues of approximately $8 billion, Pentair employs more than 30,000 people worldwide. COOLING SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION TABLE OF CONTENTS SELECTING A COOLING SOLUTION OVERVIEW Why Cool Electronics in the First Place?. . . . . . . . . . . Heat Ruins Electronics. . . . . . . . . . . . . . . . . . . . . . . . . Sources of Heat. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Trend Toward More Damaging Heat . . . . . . . . . . . . . . . The Consequences of Damaging Heat . . . . . . . . . . . . . Conductive Enclosure Cooling. . . . . . . . . . . . . . . . . . . Fresh Air Enclosure Cooling. . . . . . . . . . . . . . . . . . . . . Sealed Enclosure Cooling . . . . . . . . . . . . . . . . . . . . . . Sealed vs. Fresh Air Enclosure Cooling. . . . . . . . . . . . 4 4 4 4 4 5 5 5 6 PACKAGED BLOWERS Rack-Mountable Blowers. . . . . . . . . . . . . . . . . . . . . 260 AIR CONDITIONERS SPECTRACOOL™ Indoor/Outdoor . . . . . . . . . . . . . . . . 28 SPECTRACOOL™ Narrow Indoor/Outdoor. . . . . . . . . . 52 SPECTRACOOL™ Compact Indoor. . . . . . . . . . . . . . . . 70 EASY SWAP Adaptor Plenums For Air Conditioners . . 78 T-SERIES Compact Outdoor. . . . . . . . . . . . . . . . . . . . 80 T-SERIES Mid-size Outdoor . . . . . . . . . . . . . . . . . . . . 88 T-SERIES Large Capacity Outdoor . . . . . . . . . . . . . . 106 GENESIS™ Top-Mount Indoor. . . . . . . . . . . . . . . . . . 116 PROAIR Harsh Environment. . . . . . . . . . . . . . . . . . . 122 Water-Cooled Indoor. . . . . . . . . . . . . . . . . . . . . . . . 132 Water-Cooled Indoor/Outdoor . . . . . . . . . . . . . . . . . 136 Water-Cooled Rack-Mount. . . . . . . . . . . . . . . . . . . . 140 HEAT EXCHANGERS SEALED ENCLOSURE COOLING Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 SEALED ENCLOSURE COOLING OVERVIEW Air Conditioner Cooling Capacity Overview . . . . . . . . . 8 Part A: Determine Internal Heat Load . . . . . . . . . . . . . 8 Part B: Determining Heat Transfer Load Overview. . . . 9 Simple Chart Method. . . . . . . . . . . . . . . . . . . . . . . . . . 9 Determine Total Heat Load. . . . . . . . . . . . . . . . . . . . . 10 Equation Method. . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Heat Exchanger Cooling Capacity Overview. . . . . . . . 11 Determine Internal Heat Load . . . . . . . . . . . . . . . . . . 11 Determine Heat Transfer. . . . . . . . . . . . . . . . . . . . . . 11 Determine Heat Exchanger Capacity . . . . . . . . . . . . . 12 FRESH AIR ENCLOSURE COOLING OVERVIEW Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 What Is Airflow? . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 What Is Static Pressure?. . . . . . . . . . . . . . . . . . . . . . 13 How is Performance Characterized? . . . . . . . . . . . . . 14 What Are the Capabilities of Each Air Mover?. . . . . . 14 Airflow Design Options. . . . . . . . . . . . . . . . . . . . . . . .15 Choosing an Air Mover. . . . . . . . . . . . . . . . . . . . . . . . 16 Power Input. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Enclosure Protection. . . . . . . . . . . . . . . . . . . . . . . . . 16 Airflow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Step 1. Determine Delta-T (ΔT). . . . . . . . . . . . . . . . . . 17 Step 2. Determine Internal Heat Load . . . . . . . . . . . . 17 Step 3. Determine Free Airflow . . . . . . . . . . . . . . . . . 18 Step 4. Estimate System Impedance. . . . . . . . . . . . . 19 Step 5. Select Your Air Mover. . . . . . . . . . . . . . . . . . . 19 Friendly Reminder . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 TECHNICAL INFORMATION UL, CE, GOST CERTIFICATION BENEFITS Standards Organization Summary and Directory Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 CE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 GOST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 UL AND IP DEFINITIONS Protection Levels. . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 SCCR Requirements per UL (Condensed version). . . . 24 EQUIPMENT PROTECTION SEALED ENCLOSURE COOLING CLIMAGUARD™ Air-to-Air Indoor. . . . . . . . . . . . . . . 144 CLIMAGUARD™ Air-to-Air Outdoor. . . . . . . . . . . . . . 160 CLIMAGUARD™ Air-to-Water Indoor. . . . . . . . . . . . . 174 THERMOELECTRIC COOLERS Thermoelectric Coolers Indoor/Outdoor. . . . . . . . . . 184 Thermoelectric Temperature Controller. . . . . . . . . . 192 Thermoelectric Condensate Manager. . . . . . . . . . . .193 VORTEX COOLERS Vortex Coolers Indoor/Outdoor. . . . . . . . . . . . . . . . . 194 Quiet Vortex A/C Enclosure Coolers, Type 4/4X/12. . 198 Vortex A/C Enclosure Coolers, Hazardous Location. 202 FRESH AIR ENCLOSURE COOLING DIRECT AIR COOLING SYSTEMS (DACS) DACS Outdoor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .206 FILTER FANS SF Side-Mount. . . . . . . . . . . . . . . . . . . . . . . . . . . . . ST Thin Side-Mount. . . . . . . . . . . . . . . . . . . . . . . . . SR Top-Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Filter Fan Shrouds. . . . . . . . . . . . . . . . . . . . . . . . . . SF/ST Replacement Filters . . . . . . . . . . . . . . . . . . . TFP Side-Mount. . . . . . . . . . . . . . . . . . . . . . . . . . . . TFP Exhaust Grilles. . . . . . . . . . . . . . . . . . . . . . . . . TFP Optional Grilles and Replacement Filters. . . . . TFP EMC Upgrade Kit. . . . . . . . . . . . . . . . . . . . . . . . Outdoor Filter Fan and Exhaust Package. . . . . . . . . 212 230 236 240 241 242 246 246 247 248 AXIAL FANS AND ACCESSORIES Compact Axial Fans. . . . . . . . . . . . . . . . . . . . . . . . . Fan Cords. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fan Cords With Inline Thermostat. . . . . . . . . . . . . . Fan Filter and Finger Guard Kit . . . . . . . . . . . . . . . . Fan Brackets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Finger Guards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250 254 254 254 255 255 AIR MOVERS Rack-Mountable Fan Package. . . . . . . . . . . . . . . . . 266 Exhaust Grilles and Replacement Filters. . . . . . . . . 267 Filter Box Fans. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268 BLOWERS Centrifugal Blowers. . . . . . . . . . . . . . . . . . . . . . . . . 270 MOTORIZED IMPELLERS AC Motorized Impellers. . . . . . . . . . . . . . . . . . . . . . 274 DC Motorized Impellers. . . . . . . . . . . . . . . . . . . . . . 282 ACCESSORIES Filter Grille Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . Louver Plate Kits. . . . . . . . . . . . . . . . . . . . . . . . . . . Louver Plate Kit Filters. . . . . . . . . . . . . . . . . . . . . . Vent Kit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ventilator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Filter Adhesive. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 290 291 291 292 292 293 ACCESSORIES CONDENSATION MANAGEMENT H2OMIT™ Vent Drains . . . . . . . . . . . . . . . . . . . . . . . 296 H2OMIT™ Thermoelectric Dehumidifier. . . . . . . . . . 298 ENCLOSURE HEATERS Touch-Safe Heaters. . . . . . . . . . . . . . . . . . . . . . . . . Semiconductor Heaters. . . . . . . . . . . . . . . . . . . . . . Electric Heaters. . . . . . . . . . . . . . . . . . . . . . . . . . . . Hazardous Location Heater . . . . . . . . . . . . . . . . . . . 300 301 303 307 CONTROLLERS Thermostat Controller. . . . . . . . . . . . . . . . . . . . . . . 308 Dual Thermostat . . . . . . . . . . . . . . . . . . . . . . . . . . . 309 Electronic Hygrotherm. . . . . . . . . . . . . . . . . . . . . . . 310 Mechanical Hygrostat. . . . . . . . . . . . . . . . . . . . . . . 311 Temperature Control Switch . . . . . . . . . . . . . . . . . . 312 Panel-Mount Fan Speed Controls. . . . . . . . . . . . . . . 313 Hazardous Location Thermostat. . . . . . . . . . . . . . . .314 PRESSURE COMPENSATION Stainless Steel Pressure Compensation. . . . . . . . . 316 Pressure Compensation. . . . . . . . . . . . . . . . . . . . . . 317 INDEX Catalog Number Index. . . . . . . . . . . . . . . . . . . . . . . 318 Product Index. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 324 FAN TRAYS Rack-Mountable Assemblies. . . . . . . . . . . . . . . . . . 256 19-in. Rack-Mountable Tray. . . . . . . . . . . . . . . . . . . 258 Rack-Mount Fan Speed Control. . . . . . . . . . . . . . . . 259 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM COOLING I PROAIR™ T-SERIES™ Water-Cooled CLIMAGUARD™ Indoor CLIMAGUARD™ Outdoor Thermoelectric TEC SPECTRACOOL™ Compact PAGE NUMBER Heat Exchangers SPECTRACOOL™ Narrow Use this handy table to match your electronic cooling requirements with the most effective Hoffman protective cooling solution. Air Conditioners SPECTRACOOL™ QUICK REFERENCE 28 52 70 122 80 132 144 160 184 SYSTEM APPLICATION For indoor industrial For harsh / corrosive environments For washdown applications For outdoor enclosures For telecommunications shelters TEMPERATURE OF THE ELECTRONICS Cooler than outside the enclosure Warmer than outside the enclosure AIR CONDITIONER COOLING CAPACITY 1000-2000 BTU/Hr (300-700 Watts) 4000-6000 BTU/Hr (1200-1800 Watts) 8000-12000 BTU/Hr (2300-3500 Watts) 20000 BTU/Hr (5900 Watts) 2-ton 23500 BTU/Hr (6900 Watts) 3-ton 42000 BTU/Hr (12300 Watts) 5-ton 59000 BTU/Hr (17300 Watts) HEAT EXCHANGER COOLING CAPACITY Less than 20 Watts/°F (30 Watts/°C) 20-60 Watts/°F (30-100 Watts/°C) More than 60 Watts/°F (100 Watts/°C) THERMOELECTRIC COOLING CAPACITY 60 Watts (178 BTU/Hr.) 100 Watts (321 BTU/Hr.) 200 Watts (567 BTU/Hr.) POWER INPUT 115 & 230 AVC 50/60 Hz 400 / 460 AVC 50/60 Hz 1-phase 400 / 460 AVC 50/60 Hz 3-phase 24 & 48 VAC MOUNTING Side Top Rack CABINET PROTECTION Type 12 Type 3R Type 4 Type 4X CABINET DIMENSION Fits 8” / 203 mm Fits 12” / 305 mm Fits 16” / 406 mm Fits 20” / 508 mm or larger II COOLING SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION 222 224 227 236 CFM SR16 459 CFM CFM SF13 571 233 CFM 220 SF13 473 ST13 231 CFM SF10 PAGE NUMBER 213 216 218 18 F/10 C ∆T COOLING CAPACITY TYPE 12/IP54 60 Hz 2 Exhaust Grilles 133 BTU’s (39 Watts) .05" Static Pressure 304 BTU’s (89 Watts) .10" Static Pressure 646 BTU’s (198 Watts) .10" Static Pressure 776 BTU’s (315 Watts) .10" Static Pressure 1,437 BTU’s (421 Watts) .15" Static Pressure 2,305 BTU’s (676 Watts) .20" Static Pressure 2,422 BTU’s (710 Watts) .20" Static Pressure 3,931 BTU’s (1,152 Watts) .35" Static Pressure 3,945 BTU’s (1,156 Watts) .45" Static Pressure 1,929 BTU’s (565 Watts) .55" Static Pressure 4,151 BTU’s (1,216 Watts) .85" Static Pressure 36 F/20 C ∆T COOLING CAPACITY TYPE 12/IP54 60 Hz 2 Exhaust Grilles 267 BTU’s (78 Watts) .05" Static Pressure 609 BTU’s (178 Watts) .10" Static Pressure 1,292 BTU’s (379 Watts) .10" Static Pressure 1,552 BTU’s (632 Watts) .10" Static Pressure 2,874 BTU’s (842 Watts) .15" Static Pressure 4,606 BTU’s (1,350 Watts) .20" Static Pressure 4,845 BTU’s (1,420 Watts) .20" Static Pressure 7,862 BTU’s (2,304 Watts) .35" Static Pressure 7,886 BTU’s (2,311 Watts) .45" Static Pressure 3,859 BTU’s (1,131 Watts) .55" Static Pressure 8,302 BTU’s (2,432 Watts) .85" Static Pressure 18 F/10 C ΔT COOLING CAPACITY TYPE 12/IP55 60 Hz 2 Exhaust Grilles 283 BTU’s (83 Watts) .10" Static Pressure 545 BTU’s (220 Watts) .10" Static Pressure 646 BTU’s (290 Watts) .10" Static Pressure 1,195 BTU’s (350 Watts) .15" Static Pressure 2,064 BTU’s (605 Watts) .20" Static Pressure 2,414 BTU’s (707 Watts) .20" Static Pressure 3,300 BTU’s (967 Watts) .35" Static Pressure 3,273 BTU’s (959 Watts) .45" Static Pressure 36 F/20 C ΔT COOLING CAPACITY TYPE 12/IP55 60 Hz 2 Exhaust Grilles 565 BTU’s (165 Watts) .10" Static Pressure 1,090 BTU’s (442 Watts) .10" Static Pressure 1,292 BTU’s (580 Watts) .10" Static Pressure 2,390 BTU’s (940 Watts) .15" Static Pressure 4,128 BTU’s (1,209 Watts) .20" Static Pressure 4,828 BTU’s (1,415 Watts) .20" Static Pressure 6,600 BTU’s (1,934 Watts) .35" Static Pressure 6,547 BTU’s (1,918 Watts) .45" Static Pressure POWER INPUT 115 & 230 AC Volt 400 / 460 AC Volt 3-Phase 24 & 48 DC Volt SF13 376 ST10 Roof Mount SF09 SF05 Use this handy table to match your electronics cooling requirements with the most effective Hoffman Filter Fan. SF04 Side Mount SR16 280 QUICK REFERENCE 238 * NOTE: Roof mount filter fan capacities assume two air intake grille kits. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM COOLING III COOLING SELECTING A COOLING SOLUTION 1 763.422.2211 763.576.3200 Intro Page CHAPTER 1 SELECTING A COOLING SOLUTION OVERVIEW SEALED ENCLOSURE COOLING Sealed enclosure cooling, also known as a “closed-loop system”, allows no outside elements inside the enclosure. It is generally required for applications operating in high temperatures— typically over 35°C/95°F—or when the enclosure is deployed in harsh environments, such as an outdoor telecom base, wastewater treatment plant, metal working, oil rig, paper mill, foundry and/or generates high heat from its own components. Keeping your electronics cool is essential to extending their life and keeping your business running. Heat can have a significant impact on electronics, causing damage and voiding manufacturers’ warranties. Cooling sensitive electronics increases service life and reduces capital expenses. 2 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION CHAPTER CONTENTS Intro Page OVERVIEW Why Cool Electronics in the First Place? . . . . . . . . . . . . . . Heat Ruins Electronics. . . . . . . . . . . . . . . . . . . . . . . . . . . . Sources of Heat . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Trend Toward More Damaging Heat. . . . . . . . . . . . . . . . . . . The Consequences of Damaging Heat. . . . . . . . . . . . . . . . . Conductive Enclosure Cooling . . . . . . . . . . . . . . . . . . . . . . Fresh Air Enclosure Cooling. . . . . . . . . . . . . . . . . . . . . . . . Sealed Enclosure Cooling. . . . . . . . . . . . . . . . . . . . . . . . . . Sealed vs. Fresh Air Enclosure Cooling. . . . . . . . . . . . . . . . 4 4 4 4 4 5 5 5 6 1 SEALED ENCLOSURE COOLING Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 SEALED ENCLOSURE COOLING OVERVIEW Air Conditioner Cooling Capacity Overview. . . . . . . . . . . . . 8 Part A: Determine Internal Heat Load. . . . . . . . . . . . . . . . . 8 Part B: Determining Heat Transfer Load Overview . . . . . . . 9 Simple Chart Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Determine Total Heat Load. . . . . . . . . . . . . . . . . . . . . . . . 10 Equation Method. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Heat Exchanger Cooling Capacity Overview . . . . . . . . . . . 11 Determine Internal Heat Load. . . . . . . . . . . . . . . . . . . . . . 11 Determine Heat Transfer. . . . . . . . . . . . . . . . . . . . . . . . . . 11 Determine Heat Exchanger Capacity. . . . . . . . . . . . . . . . . 12 FRESH AIR ENCLOSURE COOLING OVERVIEW Introduction. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 What Is Airflow?. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 What Is Static Pressure? . . . . . . . . . . . . . . . . . . . . . . . . . 13 How is Performance Characterized?. . . . . . . . . . . . . . . . . 14 What Are the Capabilities of Each Air Mover?. . . . . . . . . . 14 Airflow Design Options. . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Choosing an Air Mover . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Power Input. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 Enclosure Protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Airflow. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16 Step 1. Determine Delta-T (ΔT). . . . . . . . . . . . . . . . . . . . . 17 Step 2. Determine Internal Heat Load. . . . . . . . . . . . . . . . 17 Step 3. Determine Free Airflow. . . . . . . . . . . . . . . . . . . . . 18 Step 4. Estimate System Impedance . . . . . . . . . . . . . . . . 19 Step 5. Select Your Air Mover. . . . . . . . . . . . . . . . . . . . . . 19 Friendly Reminder. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 FRESH AIR ENCLOSURE COOLING Fresh air cooling, referred to as an “open-loop system”, ventilates fresh air through the cabinet, exhausting heat away from hot electronics. Fresh air cooling is optimal when the electronics system is deployed in a relatively clean and cool environment, such as an office building, data networking center or light-duty factory. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 3 Selecting A Cooling Solution Overview WHY COOL ELECTRONICS IN THE FIRST PLACE? OVERVIEW Keeping your electronics cool is essential to extending their life and keeping your business running. HEAT RUINS ELECTRONICS 1 The life expectancy of electronics is cut in half every 10 C / 18 F they operate above room temperature. Operating electronics above certain temperatures can void manufacturers’ warranties, making proper cooling essential. Cooling vital electronics increases service life and reduces capital expenses over the long-term. SOURCES OF HEAT Damaging heat can come from a variety of sources. Inside the cabinet, heat can come from: • AC power supplies • C ontrollers, drives and servos • Transformers and rectifiers • P rocessors and server racks • Radio equipment • A nd other electronic components Electronics Life Expectancy with Every 10° C Rise over Room Temperature Heat also comes from sources outside the enclosure such as: • S olar heat gain • Welding processes • P aint oven • Blast furnace • Foundry equipment TREND TOWARD MORE DAMAGING HEAT For the foreseeable future, the trend is toward increasing levels of heat in electronics, not less, because the market’s thirst for more information processing capacity and speed continues to grow. This trend is known as “Moore’s Law.” More powerful data-processing electronics generate extra heat with virtually every new system that is designed. There is no guarantee that an application which did not require much, if any, cooling in the past will not need cooling in the future. The new system likely has more functionality and will probably require some form of cooling as a result. Moore’s Law Named after the founder of Intel Watts 100 80 60 40 20 Performance = Heat 0 Watts +2 +2 +2 +2 Processor Heat Dissipation THE CONSEQUENCES OF DAMAGING HEAT Heat build-up can adversely affect industrial controls and sensitive electronic systems as follows: • De-rated drive performance • I /C-based devices experience intermittent fluctuations • M TBF decreases exponentially • C atastrophic failure The costs when a factory line or electronic system fails can include: • P roductivity losses • C omponent replacement costs • L ate shipments • Customer dissatisfaction • L ost revenue • C ell phone tower outage • Breach in homeland security Direct costs to a business can be as much as $50,000 per hour of system downtime. 4 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Selecting A Cooling Solution Overview CONDUCTIVE ENCLOSURE COOLING This is a passive way to cool electronics. It simply allows the heat to radiate through the cabinet walls. Conductive enclosure cooling works well with electronics systems that have small heat loads (<50 W) and cool air around the enclosure (<78 F/25 C). If heat is an issue, one option within this type of cooling is to increase cabinet size to create more surface area to speed the transfer of heat. However, growing cabinet size is often not a practical solution because of space limitations and the greater heat loads associated with today’s high-power electronics. 1 FRESH AIR ENCLOSURE COOLING This is an active way to manage heat in electronics applications. This type of cooling ventilates fresh air through the cabinet, exhausting heat away from the hot components. Fresh air enclosure cooling may be used when the electronics system is deployed in a relatively clean and cool environment such as an office building, data networking center or light-duty factory. Options for cooling electronic enclosures with fresh air include filter fans, fan trays, motorized impellers and packaged blowers. Fresh air enclosure cooling is known as an “open-loop system” because no significant seal is maintained to protect electronic components from harmful elements such as dirt, water, metal filings and corrosive fumes. SEALED ENCLOSURE COOLING This is another active way to cool electrical components. This type of cooling maintains the seal of the enclosure—using an air conditioner or heat exchanger as examples—to remove heat from inside the electronics cabinet. Protective cooling is generally required when the electronics application: (1) operates in high temperatures, typically over 95 F/35 C, (2) is deployed in a harsh environment such as an outdoor telecom base station, wastewater treatment plant, metal working operation, oil rig platform, paper mill, foundry and/or (3) generates a high heat load from its own components, usually more than 500 W. Options for sealed enclosure cooling include air conditioners, air-to-air heat exchangers, air-to-water heat exchangers, thermoelectric coolers and vortex coolers. Sealed enclosure cooling is known as a “closed-loop system” because the seal of the electrical cabinet is maintained, allowing no elements which can damage the electronics inside the enclosure. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 5 Selecting A Cooling Solution Overview SEALED VS. FRESH AIR ENCLOSURE COOLING Since heat dissipation is often not a solution, we will limit our choices to sealed vs. fresh air enclosure cooling. Use the environmental and electronic system criteria in the table below to determine whether sealed or fresh air enclosure cooling is most appropriate for your application. Choosing Sealed vs. Fresh Air Enclosure Cooling Specifying protective cooling that keeps your electronics components sealed from the outside environment versus using fresh air cooling to remove damaging heat depends on the following profile of your system application (check one side or the other for each of the six criteria): 1 FRESH AIR Clean Air / Some Dust / Dripping Water Moderate to Low (typically under 35 C / 95 F) Somewhat to Well-Above Ambient Temperature Moderate to Low Wide Moderate to Low (typically under 3000 Watts) CRITERIA SYSTEM OPERATING ENVIRONMENT TEMPERATURE OUTSIDE OF THE ENCLOSURE TEMPERATURE RATING OF THE ELECTRONICS HUMIDITY OUTSIDE OF THE ENCLOSURE SEALED Dirty / Wet / Metal Filings / Outdoors / Corrosive Fumes Hot (typically over 35 C / 95 F) Below to Somewhat Above Ambient Temperature High Relative Humidity TEMPERATURE RANGE FOR THE ELECTRONICS Narrow / Precise SYSTEM POWER DRAW / HEAT LOAD Moderate to High (typically over 3000 Watts) If most of your assessments fell on the fresh air side, then a filter fan, fan tray, motorized impeller or blower is probably the correct cooling solution for your application. However, if most of your assessments were on the protective side, then an air conditioner or heat exchanger is likely the right cooling solution for your electronics system. 6 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Selecting A Cooling Solution Sealed Enclosure Cooling INTRODUCTION SEALED ENCLOSURE COOLING Assuming that sealed enclosure cooling is needed for the application, there are two basic choices—air conditioners or heat exchangers. An air conditioner should be specified when: • T he temperature inside the enclosure must be maintained at or below the ambient temperature • Humidity must be removed • A moderate to high heat load is being produced by the electronic system A heat exchanger can be used to transfer heat from inside the enclosure to the outside atmosphere when: • T he electronic components can operate at a temperature above the ambient air temperature • Humidity is not a factor • A low to moderate heat load is being produced by the electronic system EQUIPMENT PROTECTION 1 Air Conditioner PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Heat Exchanger Cooling 7 Selecting A Cooling Solution Sealed Enclosure Cooling Overview AIR CONDITIONER COOLING CAPACITY OVERVIEW SEALED ENCLOSURE COOLING OVERVIEW The cooling capacity of an air conditioner needs to match or exceed the amount of total heat load generated by the electronic system. Total heat load comes from two sources: (a) the electronic components themselves which is called “internal heat load” and (b) the ambient heat outside the enclosure which is known as the “heat transfer load.” Most engineers and cooling suppliers determine internal heat load. However, the impact from the heat transfer load is easily overlooked. Heat transfer load can significantly add to the total heat load of the system, especially if the outside air temperature is high and/or the enclosure is located in the sun. 1 Thus, the total heat load to be removed from the electrical enclosure by the air conditioner is the sum of the internal heat load and the heat transfer load. TOTAL HEAT LOAD = INTERNAL HEAT LOAD + HEAT TRANSFER LOAD PART A: DETERMINE INTERNAL HEAT LOAD The internal heat load comes from the amount of waste heat generated inside the enclosure by the electronic components and is expressed in Watts (W). There are several methods to determine internal heat load, depending on data availability. Method 1. Heat Load Data from Each Electronics Component Manufacturer One way to estimate internal load is to gather heat load data from the manufacturers of the electronics components inside the cabinet. They may know the amount of heat their equipment is generating. If more than one control or other electronics components are inside the enclosure, it will be necessary to add together all the estimates of heat load to determine total internal heat load. Method 2. Component Power – Component Efficiency A second method is to establish the Watts of power used by each electronic component. Derive Watts of power by multiplying the amp draw of each device by its voltage. Then subtract the efficiency of each component from its estimated power use. Add up the outcomes to get the total internal heat load. INTERNAL HEAT LOAD = COMPONENT POWER (W) - COMPONENT EFFICIENCY (for each electrical device) For example: An electronic system uses two components that draw 115 VAC at 15 amps. Each has a rated efficiency of 90%. Put another way, 10% of each device is inefficient. Unused power becomes generated heat. Thus the estimated internal heat load is: Device Power = 115 x 15 = 1725 W Total Power = 2 x 1725 = 3450 Less Efficiency = 3450 x (1 - .90) Total Heat Load = 345 W Method 3. Incoming – Outgoing Power A third approach is to estimate the power going into the enclosure and the power coming out of it. The difference becomes the estimated amount of internal heat load. The amps and volts of each electrical line going in are multiplied to determine Watts, then they’re added together. The same is done for the electrical line(s) coming out of the application. The outgoing Watts are then subtracted from the incoming Watts. INTERNAL HEAT LOAD = INCOMING POWER (W) – OUTGOING POWER (W) For example: An enclosure has three input lines of 230 VAC at 11, 6 and 4 A. It has one output control line of 115 VAC at 9 A. Incoming Power = (230 x 11) + (230 x 6) + (230 x 4) = 4830 W Outgoing Power = 115 x 9 = 1035 W Total Heat Load = 4830 – 1035 = 3795 W Method 4. Automated Equipment Horsepower This fourth method applies only to industrial automation equipment that operates with horsepower (hp) such as variable frequency drives (VFDs). 1 hp = 745.6 W. Thus, the internal heat load from a 3-hp VFD is 2237 W, less its efficiency which is typically 93-95%. For example: A cabinet has three 5-hp VFDs with 95% efficiency. VFD Watts = 5 hp x 745.6 x 3 = 11184 Adjusted Watts = 11184 x (1 - .95) = 559 Total Heat Load = 559 x 1.25 = 699 W 1.25 is an assumed “safety” margin for other minor heat-producing components. 8 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Selecting A Cooling Solution Sealed Enclosure Cooling Overview PART B: DETERMINING HEAT TRANSFER LOAD OVERVIEW Heat transfer load is the ambient heat outside the enclosure conducting itself through the cabinet walls toward the electronics (heat energy travels from the hottest to coldest location). When an air conditioner cools the enclosure temperature lower than the ambient air outside, additional heat load is drawn into the cabinet which the air conditioner needs to remove. The higher the ambient temperature and/or the presence of solar heat gain (the “greenhouse effect”) on the enclosure, the more cooling capacity is required. Determining heat transfer load requires that you know the total surface area of the cabinet, less any non-conductive surface area such as the enclosure side mounted to a wall. It also requires that you determine ΔT, which is the difference between maximum ambient temperature and the maximum temperature rating of the electronics components. 1 There are two methods for determining heat transfer load—the simple chart method and the equation method. SIMPLE CHART METHOD This method is reasonably accurate for most indoor industrial systems where there is no unusual air movement and insulation is not typically used inside the enclosure. The process also provides a ballpark result for outside plant and telecommunications applications, taking into account solar heat gain. However, it does not incorporate the impact of wind or cabinet insulation. If either is present, then the equation method is more precise. Step A. Determine ΔT in °F or °C. Step B. Find the heat transfer per ft. 2 or m2 on the chart below, using ΔT and the proper cabinet material curve. Step C. Multiply the heat transfer per ft. 2 or m2 by the total surface area of the enclosure that will conduct heat. (Remember to exclude surfaces such as a side mounted to a wall.) For example: A painted steel cabinet has 80 ft. 2 of surface area and will be located in a maximum ambient temperature of 95 F. The rated temperature of the electronics is 75 F. ΔT = 95 - 75 = 20 F Heat Transfer = 4 W/ft. 2 (from chart) Total Heat Transfer Load = 80 x 4 = 320 W The estimate for heat transfer load ends here, unless the electronic system will be deployed outdoors. Then solar heat gain needs to be added to the total heat transfer load calculated above. Solar heat gain is determined much the same way as heat transfer per ft. 2 or m2 , using a similar chart. SURFACE AREA (ft. 2) = [2AB (in.) + 2BC (in.) + 2AC (in.)] ÷ 144 SURFACE AREA (m2) = [2AB (mm) + 2BC (mm) + 2AC (mm)] ÷ 1000000 Total Heat Transfer Load = Heat Transfer per ft. 2 or m2 x Cabinet Surface Area For example: The painted cabinet above is in ANSI 61 gray. Thus, 7 W/ft. 2 need to be added to the heat transfer load which is 560 W (7 x 80 ft. 2). Total Heat Transfer Load consequently becomes 720 W. The result does not include insulation which can significantly reduce heat transfer load. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 9 Selecting A Cooling Solution Sealed Enclosure Cooling Overview EQUATION METHOD Heat transfer load may also be determined by equation. This method should be used when at least one of the following criteria are found in the electronic system: • Moderate to high airflow within the cabinet • Outdoor applications that involve breezes or gusty winds • Insulation used within the cabinet to offset the impact of solar heat gain The governing equations for heat transfer load are: 1 English System (°F, inches and feet): q = (To - Ti) ÷ [(1/h o) + (1/hi) + R] hi = Convective heat transfer coefficient inside the cabinet Still air: h = 1.6 Moderate air movement: h = 2.0 Blower (approx. 8 ft. 3 /sec.): h = 3.0 R = Value of insulation lining the interior of the enclosure walls No insulation: R = 0.0 1/2 in. or 12 mm: R = 2.0 1 in. or 25 mm: R = 4.0 1-1/2 in. or 38 mm: R = 6.0 2 in. or 51 mm: R = 8.0 q = (125 - 75) ÷ [(1/6) + (1/2) + 4] q = (50) ÷ (.16 + .5 + 4) q = 50 ÷ 4.66 q = 10.7 BTU/hr./ft. 2 Metric System (°C, millimeters and meters): (q = (To - Ti) ÷ [(1/h o) + (1/hi) + R] x 5.67 Definition of Variables— q = Heat transfer load per unit of surface area To = Maximum ambient temperature outside the enclosure Ti = Maximum rated temperature of the electronics components h o = Convective heat transfer coefficient outside the cabinet Still air: h = 1.6 Relatively calm day: h = 2.5 Windy day (approx. 15 mph): h = 6.0 Total Heat Transfer Load 10.7 x 72 = 770 BTU/hr. or 770 ÷ 3.413 = 226 W Since the cabinet is outdoors, and assuming it is painted ANSI 61 gray and located in the sun, extra solar load needs to be added to the outcome above which is 504 Watts (7 W per ft. 2 x 72 ft. 2). Total Heat Transfer Load with Extra from Solar Heat Gain 226 + 504 = 730 W DETERMINE TOTAL HEAT LOAD Total heat load to be removed from the electrical enclosure by the air conditioner is the sum of internal heat load plus heat transfer load. TOTAL HEAT LOAD (C) = INTERNAL HEAT LOAD (A) + HEAT TRANSFER LOAD (B) Thus, one adds together the result from Part A to the outcome from Part B. For example: The internal heat load from one of the examples above was 3795 Watts. The heat transfer load from the other example above was 730 W. Therefore, total heat load is 3795 + 730 = 4525 W. To convert Watts into BTU/hr. to determine air conditioner capacity in the English system, multiply by 3.413. 4525 W is then 15444 BTU/hr. Power input, protection level and dimensions of the air conditioner also need to fit system requirements. Caution! Do not simply match the nominal cooling capacity of the air conditioner model with the total heat load result above. Be sure to know the maximum ambient temperature outside the enclosure as well as the rated temperature of the electronic components. Apply these temperatures to the performance curves provided by the cooling manufacturer to select an appropriately sized air conditioner. Failure to do so may under-size your air conditioner as much as 20% - 25%, thereby under-cooling the electronics and making the application vulnerable to potential over-heating issues. 10 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Selecting A Cooling Solution Sealed Enclosure Cooling Overview HEAT EXCHANGER COOLING CAPACITY OVERVIEW Cooling with an air-to-air heat exchanger assumes the electronic components in your system are able to operate above the ambient temperature outside the enclosure. If this is not the case, then an air conditioner must be used. Selecting a heat exchanger is similar to specifying an air conditioner in that the cooling capacity of the unit must remove the internal heat load from the electrical enclosure. However, since the conductive cooling nature of the cabinet itself removes some of the heat from the system, heat transfer should be subtracted from internal heat load (versus added in the case of air conditioners). Because the cooling capacity of heat exchangers is expressed in terms of Watts/°F or Watts/°C, an extra step is necessary to convert net heat load into a result used to select the appropriate heat exchanger. Divide the net heat load by the ΔT which is the difference between the maximum ambient temperature outside the enclosure and the maximum temperature rating of the electronic components. HEAT EXCHANGER CAPACITY (C) = [INTERNAL HEAT LOAD (A) – HEAT TRANSFER (B)] / ΔT DETERMINE INTERNAL HEAT LOAD Internal heat load stems from the amount of waste heat generated inside the enclosure by the electronic components and is expressed in Watts. To determine internal heat load, follow one of the four options outlined in the air conditioner “Determine Internal Heat Load” section on page 8. DETERMINE HEAT TRANSFER In air-to-air heat exchangers, heat transfer is actually cabinet heat loss because the heat inside the enclosure is conducting itself through the cabinet walls toward the cooler temperature outside the enclosure. That is why heat transfer is subtracted from internal heat load to arrive at total net heat load. To determine heat transfer you need to know the total surface area of the cabinet, less any non-conductive surface area such as the enclosure side mounted to a wall. You must also determine ΔT which is the difference between maximum ambient temperature and the maximum temperature rating of the electronic components. There are two methods to determine heat transfer—the simple chart method and the equation method. The simple chart method may be used for nearly all indoor heat exchanger applications. The equation method needs to be applied when air movement outside or inside the electrical enclosure is high, or for outdoor applications. Here are the steps for the simple chart method: Step A. Determine ΔT in °F or °C. Step B. Find the heat transfer per ft. 2 or m2 from the Heat Transfer graph on page 9, using ΔT and the proper cabinet material curve. Step C. Multiply the heat transfer per ft. 2 or m2 by the total surface area of the enclosure that will conduct heat. (Remember to exclude surfaces such as a side mounted to a wall.) SURFACE AREA (ft. 2) = [2AB (in.) + 2BC (in.) + 2AC (in.)] ÷ 144 SURFACE AREA (m2) = [2AB (mm) + 2BC (mm) + 2AC (mm)] ÷ 1,000,000 Heat Transfer (Cabinet Heat Loss) = Heat Transfer per ft. 2 or m2 x Enclosure Surface Area The estimate for heat transfer ends here, unless the electronic system will be deployed outdoors, or airflow inside or outside the enclosure is high. Then the equation method needs to be used to determine heat transfer (cabinet heat loss). For the equation method, follow the steps on page 9 in the air conditioner selection section. The result will be a negative number; the negative sign should be ignored when deducting heat transfer from internal heat load. Caution! If the result of the equation method is a positive number, then this means that you want the electronics temperature inside the cabinet to be lower than the temperature outside the enclosure. In this case, an air conditioner should be specified for the electronics system. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 11 1 Selecting A Cooling Solution Sealed Enclosure Cooling Overview DETERMINE HEAT EXCHANGER CAPACITY Air-to-air heat exchanger capacities are not provided in terms of Watts or BTUs/hr. of cooling like air conditioners. Instead, they are expressed in terms of Watts/°F or Watts/°C. Thus, the final step in determining heat exchanger capacity is to divide the total net heat load by ΔT. Then select the heat exchanger with the same or higher Watts/°F or Watts/°C as the outcome of this process. —Indoor Industrial Example— 1 An electronic system uses two components that draw 230 VAC at 7.5 A. Each has a rated efficiency of 90%. They are protected in a painted steel cabinet that is 60 in. (1524 mm) tall, 36 in. (914 mm) wide and 18 in. (457 mm) deep. The system will be located in a maximum ambient temperature of 80 F (27 C). The rated temperature of the electronics is 95 F (35 C). HEAT EXCHANGER CAPACITY (C) = [INTERNAL HEAT LOAD (A) – HEAT TRANSFER (B)] ÷ ΔT Internal heat load (A) may be determined using the “Component Power – Component Efficiency” method on page 8, given the available information. In this example, the estimated heat load is: Device Power = 230 x 7.5 = 1725 W Total Power = 2 x 1725 = 3450 Less Efficiency = 3450 x (1 - .90) Internal Heat Load = 345 W —Outdoor Example— A telecom system draws a total of 5,000 W; its efficiency is 85%. It is protected in a steel cabinet that is 72 ft. 2 (6.69 m2) and painted with RAL 7035 light-gray paint. The enclosure walls are lined inside with 1 in. (25 mm) of insulation. The application will be deployed in a maximum ambient outdoor temperature of 104 F (40 C) with occasional winds reaching 15+ mph. The rated temperature of the electronics is 114 F (46 C). Air circulation inside the cabinet is moderate. HEAT EXCHANGER CAPACITY (C) = [INTERNAL HEAT LOAD (A) – HEAT TRANSFER (B)] ÷ DELTA ΔT Internal heat load (A) is determined using the “Component Power – Component Efficiency” method on page 8. In this example, the estimated heat load is as follows: Total System Power = 5000 W Less Efficiency = 5000 x (1 - .85) Internal Heat Load = 750 W Heat transfer (B) is derived using the equation method, since this is an outdoor application. For brevity, we will assume the English system (°F, inches and feet). q = (To - Ti) ÷ [(1/h o) + (1/hi) + R] Heat transfer (B) is derived using the simple chart method, since this is an indoor industrial application. Both cabinet surface area and ΔT are needed to determine heat transfer. Cabinet surface area is 54 ft. 2 or 5.02 m2 (from surface area formula on page 9). ΔT is 15 F (8 C)—the difference between ambient temperature and the rated temperature of the electronics. “q” is heat transfer per surface area. For an explanation of the other variables, see “Equation Method” on page 10. Heat Transfer (Cabinet Heat Loss) = Heat Transfer per ft. 2 or m2 x Enclosure Surface Area Total Heat Transfer = 2.14 x 72 ft. 2 = 154 W (negative sign is ignored) Using the painted steel curve on the Heat Transfer chart on page 9, heat transfer per ft. 2 or m2 is 3 W/ft. 2 or 32.5 W/m2 . Heat Transfer = 3 W/ft. 2 x 54 ft. 2 = 162 W ΔT is 10 F — the difference between ambient temperature and the rated temperature of the electronics. Now that we know internal heat load, heat transfer and ΔT, we can determine heat exchanger capacity as follows: HEAT EXCHANGER CAPACITY (C) = [345 WATTS (A) – 162 WATTS (B)] ÷ 15 F (or 8 C) HEAT EXCHANGER CAPACITY (C) = 12 W/°F or 22 W/°C The result is minimum heat exchanger capacity. If no heat exchanger model is similar to the result, choose the next largest size to ensure adequate electronics cooling. q = (104 - 114) ÷ [(1/6) + (1/2) + 4] q = -2.14 W/ft.2 HEAT EXCHANGER CAPACITY (C) = [750 W (A) – 154 W (B)] ÷ 10 F HEAT EXCHANGER CAPACITY (C) = 60 W/°F As in the indoor industrial example, the above result is minimum heat exchanger capacity. If no heat exchanger model is similar to the result, choose the next largest size to ensure adequate electronics cooling. Power input, protection level and dimensions of the heat exchanger also need to fit the system. Power input, protection level and dimensions of the heat exchanger also need to fit the system. 12 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Selecting A Cooling Solution Fresh Air Enclosure Cooling Overview INTRODUCTION FRESH AIR ENCLOSURE COOLING OVERVIEW There are many standard air movers for electronics cooling on the market today. Common options include: Compact Axial Fans Filter Fan As one may conclude by looking at the products, each fresh air cooling solution can vary in terms of: • G eneral vs. concentrated airflow • A mount of air volume (CFM or M 3 /Hr.) • A bility to overcome airflow restriction caused by electronics components (static pressure—Inches of H2 O or Pascals) • C omponent price • Power input (AC or DC volt) • A bility to protect the electronics from dust and water 1 However, before we begin to briefly review the advantages and disadvantages of each air mover, we first need to understand two important concepts, airflow and static pressure, because each fresh air cooling solution can be quite different with these factors. Server Rack Fan Tray Motorized Impeller Centrifugal Blower WHAT IS AIRFLOW? Airflow is the volume of air that a fan, impeller or blower can move. In the English system, airflow is measured in cubic feet per minute or CFM. In the Metric system, airflow is defined as cubic meters per hour or M 3 /Hr. Electronic systems with low heat loads (100 to 1000 Watts) require less airflow to cool the components. Cabinets with moderate to high heat loads (more than 1000 Watts) need more airflow. WHAT IS STATIC PRESSURE? Static pressure is air restriction created by the components inside the enclosure. In the English system, static pressure is expressed in Inches of Water or In. H2 O. In the Metric system, static pressure is Pascals or Pa. Systems with loosely packed components have low static pressure (0.24 to 0.50 In. H2 O) and use a smaller, less powerful air mover such as a tube axial fan or filter fan for cooling. However, cabinets that are moderately to densely packed with electronics (0.75 In. H2 O or more) require a larger, more powerful air mover or multiple air movers. Low Static Pressure High Static Pressure Lightly Packed Moderately Packed Densely Packed Electronics Electronics Electronics Under 0.75 In. H2O 0.75 - 1.75 In. H2O Over 1.75 In. H2O (187 Pa) (187 - 436 Pa) (436 Pa) EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 13 Selecting A Cooling Solution Fresh Air Enclosure Cooling Overview HOW IS PERFORMANCE CHARACTERIZED? Each air mover is commonly rated based on its airflow and static pressure capability known as a “performance curve.” $LU0RYHU3HUIRUPDQFH&XUYH([DPSOH 0+U +U $LU0RYHU 3HUIRUPDQFH&XUYH 3D LQRI+ 6WDWLF3UHVVXUH 1 Air mover manufacturers determine the performance curve for each of their products by placing the unit in a test chamber to determine its precise airflow and static pressure. 6WDWLF3UHVVXUH $LU $LUIORZ In a 0 static pressure electronics system, the air mover provides 325 CFM of airflow. Conversely, at 1.6 In. of H2 O static pressure (a moderately packed cabinet), the air mover provides 0 airflow. $LU $LUIORZ &)0 WHAT ARE THE CAPABILITIES OF EACH AIR MOVER? Each air mover such as a tube axial fan, filter fan, fan tray, motorized impeller and centrifugal blower performs in a different way. A summary of the characteristics and applications for each of these popular fresh air cooling products is outlined in the table below. Axial fans, filter fans and fan trays generally provide low to moderate airflow in electronic systems with low static pressure. Most are used with VAC applications. Filter fans provide an extra level of enclosure protection against dust infiltration (Type 12 or IP54) and water infiltration (Type 3R or IP55). With the exception of fan trays, tube axial fans and filter fans are relatively inexpensive. Motorized impellers offer moderate to high airflow and work well in electronics cabinets with moderate to high static pressure. They often provide general cooling throughout an enclosure. Motorized impellers are available in VAC and VDC inputs and are reasonably priced Centrifugal blowers deliver moderate to high airflow and overcome the system impedance that builds up in electronic cabinets with moderate to high static pressure. They’re primarily available for VAC power input and are relatively higher priced. Characteristics of Popular Air Movers Characteristics Airflow Static Pressure Voltage Input Protection Per Piece Price Typical Application 14 Cooling Axial Fans Low Low AC (some DC) None Low Spot electronics cooling Filter Fans Low - Moderate Low AC and DC Type 12 & 3R Moderate Industrial electrical cabinet cooling Fan Trays Low - Moderate Low AC (some DC) None High Datacom card and server rack cooling SUBJECT TO CHANGE WITHOUT NOTICE Motorized Impellers Moderate - High Moderate - High AC and DC None Moderate General cooling of moderate to high static pressure cabinets Centrifugal Blowers Moderate - High Moderate - High AC None High Concentrated or general cooling of high static pressure systems EQUIPMENT PROTECTION Selecting A Cooling Solution Fresh Air Enclosure Cooling Overview AIRFLOW DESIGN OPTIONS A typical air mover system design “pushes” cool air into the bottom of the electronics cabinet and exhausts the warm air out the top “Push” Design Warm air out the exhaust grille The “pull” approach is less desirable because it de-pressurizes the enclosure. If poor seals are in the cabinet at a door or modular panel, for example, damaging dust could be sucked inside and onto the electrical components. However, space constraints at the bottom of the enclosure may force the engineer to design a “pull” system. For electrical systems with higher static pressure, filter fans are sometimes used in a “push/pull” approach. The reason is that two filter fans designed in “series” overcome twice the static pressure compared to one filter fan working alone with an exhaust grille. “Push/Pull” Design Cool air in through filter fan 1 Warm air out with filter fan To reduce exhaust grille static pressure and improve cool airflow, some engineers use two exhaust grilles in their airflow design. Warm air out the exhaust grille Warm air out the exhaust grille Roof-mount air movers are also available. Engineers occasionally employ them due to space constraints lower in the enclosure or for other reasons. Two exhaust grilles are recommended to ensure adequate airflow through the enclosure. “Push” Design with Dual Exhaust Warm air out through roof-mount filter fan Cool air in through filter fan Another option is to use a reverse airflow fan and mount it high in the enclosure to “pull” cool air through the enclosure. “Pull” Design Cool air in through filter fan Warm air out through roof-mount filter fan Roof-Mount Design Warm air out the filter fan Cool air in through grille Cool air in through grille Roof-mount air mover designs also pose the risk of pulling dust into the enclosure through poor seals. Cool air in through grille EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 15 Selecting A Cooling Solution Fresh Air Enclosure Cooling Overview CHOOSING AN AIR MOVER Three overall considerations are applied when selecting a filter fan: voltage input, enclosure protection and airflow requirement. POWER INPUT Narrowing the choice of filter fans based on voltage input is quite simple. If the voltage available in the electronics system to power the filter fan is AC, then an VAC filter fan is chosen. If the voltage for the application is DC, then a VDC filter fan is specified. 1 The voltage level of the filter fan’s power input also needs to be taken into consideration. For example, if the voltage input is 115 VAC, then a 115 VAC filter fan should be specified. If the voltage input is 24 VDC, then a 24 VDC impeller is required. Filter fans are commonly available in 115, 230 and 460 3-phase 50/60 Hz VAC as well as 24 VDC. Some manufacturers such as Pentair Technical Products offer 48 VDC due to the trend toward using this power input in some electronic systems. ENCLOSURE PROTECTION Another important consideration is selecting an air mover that maintains the protection level of the electrical enclosure. U.S. standards of protection generally include: Type 1 – For indoor use to protect against contact with the enclosed equipment Type 12 - For indoor use to protect against dust, falling dirt and dripping non-corrosive liquid such as water Type 3R – For outdoor use to protect against rain and sleet Type 4 – For outdoor or indoor use to protect against windblown dust and rain, splashing water and hose-directed water Type 4X – For outdoor or indoor use to protect against corrosion, windblown dust and rain, splashing water and hose-directed water European standards of protection include: IP54 – Dust must not enter in sufficient quantity to interfere with the satisfactory operation of the equipment; complete protection against contact; water splashing against the enclosure from any direction shall have no harmful effect. IP55 – Dust must not enter in sufficient quantity to interfere with the satisfactory operation of the equipment; complete protection against contact; and water projected by a nozzle against enclosure from any direction shall have no harmful effects. IP65 – No ingress of dust; complete protection against contact; and water projected by a nozzle against enclosure from any direction shall have no harmful effects. AIRFLOW Choosing a filter fan with the right airflow or cooling capacity is as important as voltage input and enclosure protection. However, the process is a little more involved. Generally, smaller heat loads in the electronics system will require a filter fan with a lower airflow rate (CFM or M 3 /Hr.). Moderate to high heat loads will need a larger, more powerful filter fan or multiple filter fans to move enough air to cool the electronics components. The following 5-step process results in a filter fan specification that should generally work in your electronics system. 1. Determine Delta-T 2. Determine Internal Heat Load 3. Determine Free Airflow 4. Estimate System Impedance 5. Select Your Filter Fan These five steps yield a ballpark result. A filter fan sample should always be tested in the actual electrical system itself to confirm that its performance provides adequate airflow. The next section outlines the 5-step filter fan selection process in more detail. 16 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Selecting A Cooling Solution Fresh Air Enclosure Cooling Overview STEP 1. DETERMINE DELTA-T (ΔT) Delta-T is the difference between maximum desired temperature for the electronics and maximum temperature outside the enclosure. It is important to determine ΔT because cooler air will usually require less filter fan airflow whereas warmer air will typically require more airflow. Maximum Electronics Temperature Maximum Ambient Temperature Maximum desired temperature for the electronics is identified by reviewing the component manufacturer’s specifications. They will often indicate that the equipment should not operate above a certain temperature such as 35 C (95 F). Maximum temperature outside the enclosure is determined by forecasting the highest potential temperature of the air around the electronics cabinet. If the application is in an indoor environment such as an air conditioned factory, the maximum temperature outside the enclosure is the temperature of the facility, such as 25 C (77 F). If the electronics system is outdoors, the maximum temperature around the cabinet is the hottest weather that the application experiences, which may be 45 C (116 F) if it’s deployed on a roof top for example. ΔT = maximum temperature desired for the electronics maximum expected ambient temperature For example: ΔT = 35 C (95 F) [maximum electronics temperature] 25 C [maximum ambient temperature] ΔT = 10 C (18 F) STEP 2. DETERMINE INTERNAL HEAT LOAD Heat load stems from the amount of waste heat generated inside the enclosure by the electronic components and is expressed in Watts. There are several methods to determine internal heat load, depending on data availability. A. Heat Load Data from Each Electronics Component Manufacturer One way to estimate internal load is to gather heat load data from the manufacturers of the electronics components inside the cabinet. If more than one control or other components are inside the enclosure, it will be necessary to add together the multiple estimates of heat load to determine total internal heat load. B. Component Power – Component Efficiency A second method is to establish the Watts of power used by each electronic component. Derive Watts by multiplying the amp draw of each device with its voltage. Then subtract the efficiency of each component from its estimated power use, adding up the outcomes for total internal heat load. INTERNAL HEAT LOAD = COMPONENT POWER (Watts) - COMPONENT EFFICIENCY (for each electrical device) For example: An electronic system uses two components that draw 115 VAC at 9.5 amps. Each has a rated efficiency of 90 percent (10 percent of each device is inefficient). Unused amounts of power become generated heat. Thus, the estimated internal heat load is: Device Power = 115 x 9.5 = 1100 Watts Total Power = 2 x 1100 = 2200 Less Efficiency = 2200 x (1 - .90) Total Heat Load = 220 Watts C. Incoming – Outgoing Power A third approach is to estimate the power going into the enclosure and the power coming out of it. The difference is the estimated amount of internal heat load. Multiply the amps and volts of each electrical line going in to determine Watts and then add them together. Do the same for the electrical line(s) coming out of the application. The outgoing watts are subsequently subtracted from the incoming watts. INTERNAL HEAT LOAD = INCOMING POWER (Watts) – OUTGOING POWER (Watts) For example: An enclosure has three input lines of 230 VAC at 11, 6 and 4 amps. It has one output control line of 115 VAC at 9 amps. Incoming Power = (230 x 11) + (230 x 6) + (230 x 4) = 4830 Watts Outgoing Power = (115 x 9) = 1035 Watts Total Heat Load = 4830 – 1035 = 3795 Watts D. Automated Equipment Horsepower The fourth method applies only to industrial automation equipment that operates with horsepower such as variable frequency drives (VFDs). 1 horsepower = 745.6 Watts. Thus, the internal heat load from a 3 horsepower VFD is 2237 Watts, less its efficiency which is typically 93 – 95 percent. For example: A cabinet has three 5 Hp VFDs with 95% efficiency. VFD Watts = 5 Hp x 745.6 x 3 = 11184 Adjusted Watts = 11184 x (1 - .95) = 559 Total Heat Load = 559 x 1.25 = 699 Watts Note: 1.25 is an assumed “safety” margin for other minor heat-producing components. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 17 1 Selecting A Cooling Solution Fresh Air Enclosure Cooling Overview STEP 3. DETERMINE FREE AIRFLOW Determining free airflow applies the results from steps 1 and 2 to the chart below. Recall that free airflow is the unimpeded airflow through the enclosure without any interference from electronics components or filter fan exhaust grilles. Select the diagonal ΔT line that closely matches the ΔT of your electronics system. Using the example from step 1, ΔT is 10 C (18 F). Then find your cabinet’s heat load along the Y-axis of the chart. In the example from step 2, heat load is 2000 Watts. Find where heat load intersects with ΔT to determine free airflow on the X-axis. Continuing the example, free airflow in this case is 360 CFM or 611 M 3 /Hr. 1 DELTA-T (Difference between Ambient & Enclosure Temperature) 5°C 40°C 30°C 20°C 10°C 9°F 72°F 54°F 36°F 18°F 10000 HEAT LOAD (Watts) 5000 2000 1000 500 100 CFM 10 M3/Hr 17 50 85 100 170 360 500 611 849 1000 1698 5000 10000 8489 16978 FREE AIRFLOW WITHOUT SYSTEM IMPEDANCE Now we need to account for system impedance, i.e., the amount of airflow interference created by the electronic components inside the cabinet. A filter fan with more than 360 CFM or 611 M 3 /Hr. of free airflow will actually be needed for this system’s design. 18 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Selecting A Cooling Solution Fresh Air Enclosure Cooling Overview STEP 4. ESTIMATE SYSTEM IMPEDANCE Static pressure or system impedance can impact the cooling performance of an air mover. Filter fans work well in electrical cabinets with low static pressure such as a large enclosure with a bare drive and few other components. They do not have enough force to push air through a cabinet with a moderate or high system impedance. Lightly Packed Moderately Packed Densely Packed Electronics Electronics Electronics Under 0.75 In. H2O 0.75 - 1.75 In. H2O Over 1.75 In. H2O (187 Pa) (187 - 436 Pa) (436 Pa) If your system design appears like the middle or right hand example, then a motorized impeller or blower is probably a better solution for the application than a filter fan. Assuming a filter fan can cool your application, the exhaust grille and electrical components inside the enclosure will reduce airflow through the system. Filter fan manufacturers will show the effect of the exhaust grille on the performance curve. However, they do not indicate the impedance curve of the electronics system because filter fan makers do not know this information. Only the specifying electronics engineer or system designer can determine this. If it is not possible to measure the exact static pressure inside an electronics cabinet, you must make an estimate and draw an approximation. 1.00 0 170 306 340 .75 450 510 680 249 Estimated Electronic Component Impedance .50 187 124 Exhaust Grille System Impedance .25 0 62 0 100 180 200 265 300 Static Pressure (Inches of Water) High Static Pressure Airflow (CFM) Static Pressure (Inches of Water) Low Static Pressure Impact of System Impedance on Free Airflow of a 376 CFM (638 M3/Hr.) Filter Fan 1 400 Airflow (CFM) In the example shown, the free airflow of a 376 CFM (638 M 3 /Hr.) air mover decreases to 265 CFM with the exhaust grille kit and down to 180 CFM when used in an actual application. Thus, a model with a performance curve similar to the one in the next graph would be too small to keep our electrical system cool because our actual target airflow is 360 CFM. STEP 5. SELECT YOUR AIR MOVER In this final step, we bring together the results of free airflow (step 3) and system impedance (step 4), using the air mover performance charts. Applying the example, we need to select a motorized impeller that delivers a minimum of 360 CFM (611 M 3 /Hr.). 255 1.00 306 510 765 866 1019 249 .75 187 Estimated Electronic Component Impedance .50 .25 0 124 Exhaust Grille System Impedance 0 150 Static Pressure (Pascals) In the performance curve shown here, 571 CFM is commonly the largest filter fan in the electronics cooling industry. Based on the estimated electronic component impedance overlaid by our imaginary engineer, it should deliver the cooling performance required by the system. Airflow (M3/Hr.) Static Pressure (Inches of Water) Identify alternative air mover models with free airflow ratings that are greater than the step 3 outcome of 360 CFM (611 M 3 /Hr.) to compensate for airflow losses created by static pressure in the system. A judgmental system impedance curve is overlaid onto the performance charts of each of the optional models, and then the model with the CFM or M 3 /Hr. closest to the target airflow is selected. Performance Curve of a 571 CFM (969 M3/Hr.) Filter Fan with Exhaust Grille and System Impedance 62 180 300 450 510 600 Airflow (CFM) FRIENDLY REMINDER This 5-step process for selecting an air mover yields a ballpark result. Be sure to test a sample of the air mover in the electrical system prototype at maximum ambient and heat load conditions to verify adequate cool airflow. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 19 COOLING TECHNICAL INFORMATION 2 763.422.2211 763.576.3200 Intro Page CHAPTER 2 TECHNICAL INFORMATION STANDARDS SUMMARY To standardize enclosure performance, organizations like NEMA, UL, CSA, IEC and VDE use rating systems to identify an enclosure’s ability to resist external environmental influences. 20 Cooling CE GOST For industrial control equipment, the CE Mark is not intended to be applied to empty enclosures because they are inactive components of a final assembly. With the CE marking, the manufacturer declares that the product conforms with the essential requirements of the applicable EU directives. The GOST Standard, approved by ISO as a local standard in Russian Federation and CIS countries, covers general and technical specifications as well as safety requirements. SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION CHAPTER CONTENTS Intro Page UL, CE, GOST CERTIFICATION BENEFITS Standards Organization Summary and Directory Overview.22 CE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 GOST. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 UL AND IP DEFINITIONS Protection Levels. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 SCCR Requirements per UL (Condensed version) . . . . . . . 24 2 UL The UL Listing Mark means that the product has met UL’s safety requirements and is suitable for factory and field installation. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 21 2 Technical Information UL, CE, GOST Certification Benefits STANDARDS ORGANIZATION SUMMARY AND DIRECTORY OVERVIEW UL, CE, GOST CERTIFICATION BENEFITS What’s in a Rating? As a way of standardizing enclosure performance, organizations like NEMA, UL, CSA, IEC and VDE use rating systems to identify an enclosure’s ability to resist external environmental influences. Resistance to everything from dripping liquid to hose-down to total submersion is defined by the ratings systems. While these ratings are all intended to provide information to help you make a safer, more-informed product choice, there are differences among them. North American Standards Organizations In North America, NEMA, UL and CSA are the commonly recognized standards organizations. Their ratings are based on similar application descriptions and expected performance. UL and CSA both require enclosure testing by qualified evaluators in their certified labs. They also send site inspectors to make sure a manufacturer adheres to prescribed manufacturing methods and material specifications. NEMA, on the other hand, does not require independent testing and leaves compliance completely up to the manufacturer. International Standards Organizations Like NEMA, IEC does not require independent testing and leaves compliance completely up to the manufacturer. Nevertheless, there are differences in how enclosure performance is interpreted. For example, UL and CSA test requirements specify that an enclosure fails the water-tight test if even a single drop of water enters the enclosure. In the IEC standards for each level of ingress protection (IP), a certain amount of water is allowed to enter the enclosure. IEC 60529 IP ratings do not specify construction requirements or degrees of protection against corrosive atmospheres, risk of explosion or conditions such as moisture or corrosive vapors. NEMA Type ratings, on the other hand, do specify construction and performance requirements for most environmental conditions. For this reason, and because the tests and evaluations for other characteristics are not identical, the IEC enclosure classification designations cannot be exactly equated with NEMA enclosure Type numbers. North American enclosure rating systems also include a rating that indicates corrosion resistance. This rating is based on the enclosure’s ability to withstand prolonged exposure to salt water spray. While the corrosion resistance rating is a good indicator that an enclosure can resist corrosion, it does not provide information on how a specific corrosive agent will affect a given enclosure material. It is best to conduct a full analysis of the specific application and environment to determine the best enclosure choice. CE For industrial control equipment, the CE Mark is not intended to be applied to empty enclosures because such enclosures are inactive components of a final assembly. The responsibility of ensuring compliance with all applicable EU directives and harmonized standards belongs with the final equipment manufacturer. GOST GOST Standard has been approved by ISO as a local standard in Russian Federation and CIS countries and is quite similar to the EN/CE standards. The GOST collection of standards covers general and technical specifications as well as safety requirements. At the time of this printing, the following countries use GOST Standard with some individual additions: Russia, Belarus, Ukraine, Moldova, Kazakhstan, Azerbaijan, Armenia, Kyrgyzstan, Uzbekistan, Tajikistan, Georgia, Turkmenistan GOST-R certification is required in order to gain customs clearance for products at the Russian borders. The GOST-R certificate indicates compliance with the Russian standards. GOST-R is valid only for Russian Federation and may not be accepted in CIS countries. There are similar, but independent regulations in each CIS country. 22 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION PROTECTION LEVELS UL AND IP DEFINITIONS NEMA, UL and CSA Ratings Enclosure Type Descriptions for Non-Hazardous Locations Indoor Type Type 1 NEMA Enclosures are intended for indoor use primarily to provide a degree of protection against contact with the enclosed equipment or locations where unusual service conditions do not exist. Enclosures are intended for indoor use primarily to provide a degree of protection against dust, falling dirt and dripping noncorrosive liquids. UL Indoor use primarily to provide protection against contact with the enclosed equipment and against a limited amount of falling dirt. Indoor use to provide a degree of protection against dust, dirt, fiber flyings, dripping water and external condensation of noncorrosive liquids. Indoor Type 12 Indoor Type 12K Enclosures with knockouts are intended for indoor use primarily to provide a degree of protection against dust, falling dirt and dripping noncorrosive liquids. Indoor use to provide a degree of protection against dust, dirt, fiber flyings, dripping water and external condensation of noncorrosive liquids. Indoor Type 13 Enclosures are intended for indoor use primarily to provide a degree of protection against dust, spraying of water, oil and noncorrosive coolant. Indoor use to provide a degree of protection against lint, dust seepage, external condensation and spraying of water, oil and noncorrosive liquids. Outdoor use to provide a degree of protection against windblown dust and windblown rain; undamaged by the formation of ice on the enclosure. Outdoor use to provide a degree of protection against falling rain; undamaged by the formation of ice on the enclosure. Outdoor Type 3 Outdoor Type 3R Outdoor Type 3RX Outdoor Type 4 Outdoor Type 4X Outdoor Type 6 • • • • • Enclosures are intended for outdoor use primarily to provide a degree of protection against windblown dust, rain and sleet; undamaged by the formation of ice on the enclosure. Enclosures are intended for outdoor use primarily to provide a degree of protection against falling rain and sleet; undamaged by the formation of ice on the enclosure. Enclosures are intended for outdoor use primarily to provide a degree of protection against corrosion, falling rain and sleet; undamaged by the formation of ice on the enclosure. Enclosures are intended for indoor or outdoor use primarily to provide a degree of protection against windblown dust and rain, splashing water and hose directed water; undamaged by the formation of ice on the enclosure. Enclosures are intended for indoor or outdoor use primarily to provide a degree of protection against corrosion, windblown dust and rain, splashing water and hose-directed water; undamaged by the formation of ice on the enclosure. Enclosures are intended for use indoors or outdoors where occasional submersion is encountered; limited depth; undamaged by the formation of ice on the enclosure. Not specifically defined. Either indoor or outdoor use to provide a degree of protection against falling rain, splashing water and hose-directed water; undamaged by the formation of ice on the enclosure. Either indoor or outdoor use to provide a degree of protection against falling rain, splashing water and hose-directed water; undamaged by the formation of ice on the enclosure; resists corrosion. Indoor or outdoor use to provide a degree of protection against entry of water during temporary submersion at a limited depth; undamaged by the external formation of ice on the enclosure. CSA General purpose enclosure. Protects against accidental contact with live parts. Indoor use; provides a degree of protection against circulating dust, lint, fibers and flyings; dripping and light splashing of non-corrosive liquids; not provided with knockouts. Indoor use; provides a degree of protection against circulating dust, lint, fibers and flyings; dripping and light splashing of noncorrosive liquids; not provided with knockouts. Indoor use; provides a degree of protection against circulating dust, lint, fibers and flyings; seepage and spraying of non-corrosive liquids, including oils and coolants. Indoor or outdoor use; provides a degree of protection against rain, snow and windblown dust; undamaged by the external formation of ice on the enclosure. Indoor or outdoor use; provides a degree of protection against rain and snow; undamaged by the external formation of ice on the enclosure. Not specifically defined. Indoor or outdoor use; provides a degree of protection against rain, snow, windblown dust, splashing and hose-directed water; undamaged by the external formation of ice on the enclosure. Indoor or outdoor use; provides a degree of protection against rain, snow, windblown dust, splashing and hose-directed water; undamaged by the external formation of ice on the enclosure; resists corrosion. Indoor or outdoor use; provides a degree of protection against the entry of water during temporary submersion at a limited depth. Undamaged by the external formation of ice on the enclosure; resists corrosion. his material is reproduced with permission from NEMA. The preceding descriptions, however, are not intended to be complete T representations of National Electrical Manufacturers Association standards for enclosures nor those of the Electrical and Electronic Manufacturers Association of Canada. This material is reproduced with permission from Underwriters Laboratories Inc. Enclosures for Electrical Equipment, UL 50, 50E and Industrial Control Panels, UL 508A. This material is reproduced with permission from the Canadian Standards Association. Underwriters Laboratories Inc. (UL) shall not be responsible for the use of or reliance upon a UL Standard by anyone. UL shall not incur any obligation or liability for damages, including consequential damages, arising out of or in connection with the use, interpretation of, or reliance upon a UL Standard. Some enclosures may have multiple ratings. For instance: 4, 12—Outdoor use; able to be used indoors with modifications; 4X, 3RX— Outdoor use; able to be used indoors with modifications; 4, 9—Can be used in both hazardous and non-hazardous locations EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 23 2 Technical Information UL and IP Definitions 2 Technical Information UL and IP Definitions IP Rating Descriptions Example Rating If 1st IP number is... 2 (protection against solid objects) and the 2nd IP number is... 3 (protection against liquids) Then the IP rating is IP23 An enclosure with this designation provides protection against touch with a finger, penetration of solid objects greater than 12 mm and spraying water. First Numeral (Solid Objects and Dust) IP 0 1 2 3 4 5 6 Protection of Persons No Protection Protected against contact with large areas of the body (back of hand) Protected against contact with fingers Protected against tools and wires over 2.5 mm in diameter Protected against tools and wires over 1 mm in diameter Protected against tools and wires over 1 mm in diameter Protected against tools and wires over 1 mm in diameter Protection of Equipment No Protection Protected against objects over 50 mm in diameter Protected against solid objects over 12 mm in diameter Protected against solid objects over 2.5 mm in diameter Protected against solid objects over 1 mm in diameter Protected against dust (limited ingress, no harmful deposit) Totally protected against dust Second Numeral (Liquid) IP 0 1 2 3 4 5 6 7 8 Protection of Equipment No Protection Protected against vertically falling drops of water, e.g. condensation Protected against direct sprays of water up to 15 degrees from vertical Protected against sprays up to 60 degrees from vertical Protected against water sprayed from all directions (limited ingress permitted) Protected against low-pressure jets of water from all directions (limited ingress permitted) Protected against strong jets of water Protected against the effects of immersion between 15 cm and 1 m Protected against long periods of immersion under pressure SCCR REQUIREMENTS PER UL (CONDENSED VERSION) Article 409 of the 2008 National Electric Code (NFPA 70) requires industrial control panels to be marked with a short circuit current rating. As specified in the National Electric Code, UL508A-2001 Supplement SB, the Standard of Safety for Industrial Control Equipment, provides an accepted method for determining the short-circuit current rating of the control panel. The SCCR rating for our air conditioners and heat exchangers has a default value of 5 kA. You may use a 5 or 10 kVA isolation transformer between the customer’s panel and our air conditioner and not have an effect on the customer’s 65 kA rating. You may use a fuse or circuit breaker with a 5 kA short circuit rating on the line side of the ACU and its branch circuit protective device and not have an effect on the customer’s 65 kA rating. The current limiting fuse or circuit breaker used on the line side of the branch circuit protection for the ACU must have a SCCR equal to or greater than that of the panel rating. Additionally, for a current limiting fuse, the customer would need to verify that the let-through current (Ip * 10^3) of the fuse is less than or equal to 5KA by referencing table SB4.2 of UL 508A. If a circuit breaker is used as feeder protection, it must be marked Current Limiting type from the manufacturer, and the panel builder would need to verify based on the manufacturers published curves that the let-through current is less than or equal to 5kA. Examples of these curves are included in UL 508A supplement SB. You can run separate circuits for the panel and the air conditioner as long as each is labeled with their individual SCCR ratings. (5 kA and 65 kA) If the customer does not implement one of the options above, then the resulting SCCR rating would be the 5 kA rating of the ACU, if that is the lowest rated component in the panel. Testing represents another option; however, if the customer does not implement these options, then the resulting short circuit rating of the panel is based on the lowest short circuit current rating of all power circuit components installed in the panel. 24 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Notes 2 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 25 Technical Information UL and IP Definitions COOLING SEALED ENCLOSURE COOLING 3 763.422.2211 763.576.3200 Intro Page CHAPTER 3 SEALED ENCLOSURE COOLING FEATURED PRODUCTS 26 Cooling SPECTRACOOL™ AIR CONDITIONERS Designed to deliver vital cooling to sensitive electronics within enclosures, SPECTRACOOL™ air conditioners provide energy-efficient, reliable cooling in rugged indoor and outdoor environments. With a variety of cooling capacities and sizes, air conditioners are ideal for applications ranging from low-profile cabinet cooling to large cabinet cooling. SUBJECT TO CHANGE WITHOUT NOTICE CLIMAGUARD™ HEAT EXCHANGERS CLIMAGUARD™ heat exchangers are an efficient, maintenancefree and low-noise solution for cooling enclosures in industrial applications. With a unique, double-seal design and small to large cooling capacities, heat exchangers protect vital electronics by effectively transferring heat and preventing damaging dirt and dust. EQUIPMENT PROTECTION CHAPTER CONTENTS Intro Page AIR CONDITIONERS SPECTRACOOL™ Indoor/Outdoor. . . . . . . . . . . . . . . . . . . . 28 SPECTRACOOL™ Narrow Indoor/Outdoor. . . . . . . . . . . . . . 52 SPECTRACOOL™ Compact Indoor. . . . . . . . . . . . . . . . . . . 70 EASY SWAP Adaptor Plenums For Air Conditioners. . . . . . 78 T-SERIES Compact Outdoor. . . . . . . . . . . . . . . . . . . . . . . . 80 T-SERIES Mid-size Outdoor. . . . . . . . . . . . . . . . . . . . . . . . 88 T-SERIES Large Capacity Outdoor. . . . . . . . . . . . . . . . . . 106 GENESIS™ Top-Mount Indoor. . . . . . . . . . . . . . . . . . . . . 116 PROAIR Harsh Environment. . . . . . . . . . . . . . . . . . . . . . .122 Water-Cooled Indoor. . . . . . . . . . . . . . . . . . . . . . . . . . . . 132 Water-Cooled Indoor/Outdoor. . . . . . . . . . . . . . . . . . . . . 136 Water-Cooled Rack-Mount. . . . . . . . . . . . . . . . . . . . . . . 140 HEAT EXCHANGERS CLIMAGUARD™ Air-to-Air Indoor. . . . . . . . . . . . . . . . . . . 144 CLIMAGUARD™ Air-to-Air Outdoor. . . . . . . . . . . . . . . . . 160 CLIMAGUARD™ Air-to-Water Indoor. . . . . . . . . . . . . . . . 174 THERMOELECTRIC COOLERS Thermoelectric Coolers Indoor/Outdoor. . . . . . . . . . . . . 184 Thermoelectric Temperature Controller. . . . . . . . . . . . . 192 Thermoelectric Condensate Manager. . . . . . . . . . . . . . . 193 VORTEX COOLERS Vortex Coolers Indoor/Outdoor. . . . . . . . . . . . . . . . . . . . 194 Quiet Vortex A/C Enclosure Coolers, Type 4/4X/12. . . . . 198 Vortex A/C Enclosure Coolers, Hazardous Location . . . . 202 3 EASY SWAP ADAPTOR PLENUMS When existing air conditioners are damaged or have reached end-of-life, Easy Swap Adaptor Plenums provide a quick and easy means for attaching new SPECTRACOOL air conditioners to the enclosure with no modifications required. EQUIPMENT PROTECTION THERMOELECTRIC COOLERS A compact design, with no refrigerant, compressors or filters required, Thermoelectric Coolers provide reliable cooling for small indoor and outdoor enclosures. With Peltier effect cooling capacities, Thermoelectric Coolers efficiently remove heat around critical electronics within an enclosure. PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 27 3 Sealed Enclosure Cooling Air Conditioners SPECTRACOOL™ INDOOR/OUTDOOR AIR CONDITIONERS G57 20000 BTU/Hr. 5861 Watt G52 8000/12000 BTU/Hr. 2300/3500 Watt G28 4000/6000 BTU/Hr. 1172/1758 Watt INDUSTRY STANDARDS • UL/cUL Listed; Type 12, 3R, 4; 4X optional; File No. SA6453 CE GOST IP 56 Internal Loop IP 34 on External Loop Telcordia GR-487 capable (Outdoor) • • • • APPLICATION • • • • • • Industrial automation Telecommunications equipment Waste water treatment systems Package handling equipment S ecurity and defense systems A nd more • FEATURES • • • • • • • • • • • • 28 nergy-efficient rotary compressor on most models E R407c and R134a earth-friendly refrigerants 115, 230 and 400/460 VAC 3-phase power input on most models UL Listed to save customers time and money with agency approvals Outdoor model operating temperature range from -40 F/-40 C to 131 F/55 C E xterior and partially recessed mounting options Attractive industrial design with minimal use of visible fasteners Reliable mechanical thermostat on enclosure side of the unit; indoor air conditioner models include digital display on ambient side Dual condenser-side air movers for performance redundancy on G52 and G57 models Galvanized sheet-metal cover for rugged factory and outdoor environments E asy-mount flanges for simple installation Cut-out adapter options for enclosures with GENESIS™ and T-Series air conditioners, enable users to easily transition to the new unit Cooling Clean AirFlow Ambient AirFlow ust-resistant condenser coil allows the unit to be run filterless D in most applications Cleanable, reusable aluminum mesh filter protects coils for maximum cooling performance Mounting hardware, gaskets and user manual furnished with the unit Every unit functionally tested before shipping Standard Indoor Air Conditioner models also include: - Active condensate management with heater strip - Power-off relay for door switch and other system requirements - Malfunction switch Standard Outdoor Air Conditioner models also include: - Telcordia GR-487 capable - Corrosion-resistant components - Malfunction switch - Compressor heater - Head pressure control - Up to 2000 Watt (G28, G52) and 3000 Watt (G57) enclosure heater SPECIFICATIONS • • Nominal cooling capacity: G28 4000 & 6000 BTU/Hr. (1172 and 1758 W) G52 8000 & 12000 BTU/Hr. (2344 and 3516 W) G57 20000 BTU/Hr. (5861 W) Outdoor model operating temperature range from -40 F/-40 C to 131 F/55 C FINISH • • AL 7035 light-gray, semi-textured powder-coat paint R O ther colors and textures available NOTES Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data G28 Models 4000/6000 BTU/Hr. (1172/1758 Watt) CATALOG NUMBER Indoor Model Indoor Model Stainless Steel Type 4X Indoor Model with Remote Access Control* Outdoor Model without Heat Pkg. Outdoor Model Partial Recessed Mount Outdoor Model without Heat Pkg. Stainless Steel Type 4X Outdoor Model with Heat Pkg. Outdoor Model with Heat Pkg. Stainless Steel Type 4X COOLING PERFORMANCE Nominal: BTU/Hr. Watts At 131 F/131 F (55 C/55 C): BTU/Hr. (50/60 Hz) W (50/60 Hz) At 95 F/95 F (35 C/35 C): BTU/Hr. (50/60 Hz) W (50/60 Hz) Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F/°C) Minimum (°F/°C) Air Flow at 0 Static Pressure: Internal loop 50 Hz (CFM / m3/hr.) External loop 50 Hz (CFM / m3/hr.) Internal loop 60 Hz (CFM / m3/hr.) External loop 60 Hz (CFM / m3/hr.) Max. Heater W (Outdoor Models) ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (W at 50/60 Hz) Max. Nominal Current (A at 50/60 Hz) Starting Current (A) Agency Approvals G280416G050 G280416G051 G280416G060 G280416G100 G280416G101 G280416G102 G280426G050 G280426G051 G280426G060 G280426G100 G280426G101 G280426G102 G280446G050 G280446G051 G280446G060 G280446G100 G280446G101 G280446G102 G280616G050 G280616G051 G280616G060 G280616G100 G280616G101 G280616G102 G280626G050 G280626G051 G280626G060 G280626G100 G280626G101 G280626G102 G280646G050 G280646G051 G280646G060 G280646G100 G280646G101 G280646G102 G280416G150 G280416G151 G280426G150 G280426G151 — — G280616G150 G280616G151 G280626G150 G280626G151 — — 4600/4900 1347/1435 4600/4900 1347/1435 4600/4900 1347/1435 6000/6400 1757/1874 6000/6400 1757/1874 5400/6000 1581/1757 4600/4900 1347/1435 4600/4900 1347/1435 4600/4900 1347/1435 6000/6400 1757/1874 6000/6400 1757/1874 5400/6000 1581/1757 4300/4600 1260/1364 R407C 20/567 4300/4600 1260/1364 R407C 20/567 4324/4655 1267/1364 R134A 16/454 5600/6000 1641/1758 R407C 20/567 5600/6000 1641/1758 R407C 20/567 5054/5685 1481/1666 R134A 16/454 131 F/55 C -40 F/-40 C 131 F/55 C -40 F/-40 C 131 F/55 C -40 F/-40 C 131 F/55 C -40 F/-40 C 131 F/55 C -40 F/-40 C 131 F/55 C -40 F/-40 C 189/321 291/494 221/375 300/509 2000 189/321 291/494 221/375 300/509 2000 189/321 291/494 221/375 300/509 189/321 291/494 221/375 300/509 2000 189/321 291/494 221/375 300/509 2000 189/321 291/494 221/375 300/509 115 50/60 +/- 10% 1138.5/1311 9.9/11.4 36.2 230 50/60 +/- 10% 1058/1334 4.6/5.8 17.7 230 50/60 +/- 10% 1058/1334 4.6/5.8 17.7 400/460 3~ 50/60 +/- 10% 680/874 1.7/1.9 7.7 80/27 80/27 Power Input Description ENCLOSURE PROTECTION UL Type CONTROLLER Description Thermostat Location Factory Thermostat Setting (°F/°C) SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Material Finish ACCESSORIES EASYSWAP Adaptor Plenum (GENESIS™ M28) EASYSWAP Adaptor Plenum (T-Series T29) UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) 400/460 3~ 115 50/60 50/60 +/- 10% +/- 10% 680/874 1138.5/1311 1.7/1.9 9.9/11.4 7.7 36.2 cUL Listed CE GOST Terminal Block 3 Type 12, 3R, 4 Standard Type 4X Stainless Steel Optional 80/27 80/27 Basic Mechanical Thermostat Enclosure Side on All Base Models 80/27 80/27 68dB(A) Galvanized Sheet Metal Standard (Optional: Stainless Steel) Powder Coat RAL 7035 Light Gray Standard Enables SPECTRACOOL to be mounted to GENESIS M28 air conditioner cutout Catalog Number PLM28G28 Enables SPECTRACOOL to be mounted to T-Series T29 air conditioner cutout Catalog Number PLT29G28 84/38 84/38 28.55/725.1 16.97/431.1 10.10/256.6 84/38 84/38 84/38 84/38 *Units with Remote Access Control utilize a digital controller and communicate via EtherNet/IP, Modbus TCP/IP and SNMP over ethernet or modbus RTU over USB. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 29 Sealed Enclosure Cooling Air Conditioners Performance Curves for G28 Models 4000 BTU/Hr. (1347/1435 Watt) G28-0416-GXXX Capacity Curves at 50 Hz Ambient Air In (°C) 30 40 20 6000 55 C 131 F 50 1758 Enclosure Air Temperature 35 C 95 F 4000 1172 25 C 77 F 2000 Cooling Capacity (W) Cooling Capacity (BTU/Hr.) 45 C 113 F 586 0 68 77 86 95 104 Ambient Air In (°F) 113 G28-0416-GXXX Capacity Curves at 60 Hz Ambient Air In (°C) 30 40 20 6000 122 0 131 50 1758 55 C 131 F Enclosure Air Temperature 35 C 95 F 4000 1172 25 C 77 F 2000 586 0 68 30 Cooling Cooling Capacity (W) 45 C 113 F Cooling Capacity (BTU/Hr.) 3 Sealed Enclosure Cooling Air Conditioners 77 86 95 104 Ambient Air In (°F) SUBJECT TO CHANGE WITHOUT NOTICE 113 122 0 131 EQUIPMENT PROTECTION Performance Curves for G28 Models 4000 BTU/Hr. (1347/1435 Watt) G28-0426-GXXX Capacity Curves at 50 Hz Without Air Filter Ambient Air In (°C) 30 40 20 50 8000 2344 45 C 113 F Cooling Capacity (BTU/Hr.) 6000 1758 35 C 95 F 25 C 77 F 4000 1172 Cooling Capacity (W) 55 C 131 F Enclosure Air Temperature 586 2000 3 0 77 Cooling Capacity (BTU/Hr.) 95 104 Ambient Air In (°F) 113 G28-0426-GXXX Capacity Curves at 60 Hz Without Air Filter Ambient Air In (°C) 30 40 20 8000 86 122 50 2344 55 C 131 F Enclosure Air Temperature 45 C 113 F 6000 0 131 1758 35 C 95 F 25 C 77 F 4000 1172 2000 Cooling Capacity (W) 68 586 0 68 EQUIPMENT PROTECTION 77 86 95 104 Ambient Air In (°F) 113 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 122 0 131 Cooling 31 Sealed Enclosure Cooling Air Conditioners Performance Curves for G28 Models 4000 BTU/Hr. (1347/1435 Watt) G28-0446-GXXX- Capacity Curves at 50 Hz; Without Filter 20 30 Ambient Air In (°C) 40 50 8000 2344 Cooling Capacity (BTU/Hr.) 6000 Enclosure Air Temperature 1758 45 C 113 F 35 C 95 F 4000 1172 25 C 77 F 2000 Cooling Capacity (W) 55 C 131 F 586 0 68 77 86 95 104 Ambient Air In (°F) 113 122 0 131 G28-0446-GXXX- Capacity Curves at 60 Hz; Without Filter 20 30 Ambient Air In (°C) 40 50 8000 2344 Enclosure Air Temperature 45 C 113 F 6000 1758 35 C 95 F 25 C 77 F 4000 1172 2000 586 0 68 32 Cooling Capacity (W) 55 C 131 F Cooling Capacity (BTU/Hr.) 3 Sealed Enclosure Cooling Air Conditioners Cooling 77 86 95 104 Ambient Air In (°F) SUBJECT TO CHANGE WITHOUT NOTICE 113 122 0 131 EQUIPMENT PROTECTION Performance Curves for G28 Models 4000/6000 BTU/Hr. (1172/1758 Watt) G28-06(1/2)6-GXXX Capacity Curves at 50 Hz Without Filter 20 30 Ambient Air In (°C) 40 50 12000 3516 Enclosure Air Temperature 55 C 131 F 2930 45 C 113 F 8000 2344 35 C 95 F 6000 1758 25 C 77 F 4000 Cooling Capacity (W) Cooling Capacity (BTU/Hr.) 10000 1172 3 2000 68 77 86 95 104 Ambient Air In (°F) 113 122 586 131 G28-06(1/2)6-G002-P#2 Capacity Curves at 60 Hz Without Filter 20 30 Ambient Air In (°C) 40 50 12000 3516 Cooling Capacity (BTU/Hr.) Enclosure Air Temperature 2930 45 C 113 F 8000 2344 35 C 95 F 6000 1758 25 C 77 F 4000 Cooling Capacity (W) 55 C 131 F 10000 1172 2000 68 EQUIPMENT PROTECTION 77 86 95 104 Ambient Air In (°F) 113 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 122 586 131 Cooling 33 Sealed Enclosure Cooling Air Conditioners Performance Curves for G28 Models 6000 BTU/Hr. (1758 Watt) G28-0646-GXXX Performance Curve 400VAC/50Hz Without Air Filter 20 30 Ambient Air In (°C) 40 50 10000 2930 Cooling Capacity (BTU/Hr.) Enclosure Air Temperature 2344 45 C 113 F 6000 1758 35 C 95 F 25 C 77 F 4000 Cooling Capacity (W) 55 C 131 F 8000 1172 2000 68 77 86 95 104 Ambient Air In (°F) 113 122 586 131 G28-0646-GXXX Performance Curve 460VAC/60Hz Without Air Filter 20 30 Ambient Air In (°C) 40 50 10000 2930 8000 Enclosure Air Temperature 2344 45 C 113 F 35 C 95 F 6000 1758 25 C 77 F 1172 4000 2000 68 34 Cooling Capacity (W) 55 C 131 F Cooling Capacity (BTU/Hr.) 3 Sealed Enclosure Cooling Air Conditioners Cooling 77 86 95 104 Ambient Air In (°F) SUBJECT TO CHANGE WITHOUT NOTICE 113 122 586 131 EQUIPMENT PROTECTION *0RGHOV%78+U9:DWW 127( 02817,1**$6.(76833/,('1276+2:1 81,76LQ>PP@ :$50 $,5287 &22/,1*+($7,1* 7+(50267$76 32:(5 ,1/(7 (1&/2685( $,5287 5(029$%/( +$1*,1* 7$%6 $0%,(17 $,5,1 &22/ $,5287 &/($1$%/(5(86$%/( $/80,180,1/(7),/7(5 ; ; 237,21$/ $&&(663$1(/ 21/<)2581,76 :,7++($7(5 ; $&&(66+2/(72>@ 2876,'(',$0(7(5'5$,1678% 3 ; [ ; 81& 02817,1* +2/(6 $&287/,1( ; &XWRXW'LPHQVLRQV Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 35 Sealed Enclosure Cooling Air Conditioners 3 Sealed Enclosure Cooling Air Conditioners *0RGHOV%78+U9%78+U9:DWW 127( 02817,1**$6.(76833/,('1276+2:1 81,76LQ>PP@ :$50 $,5287 (1&/2685( $,5287 &22/,1*+($7,1* 7+(50267$76 32:(5 ,1/(7 5(029$%/( +$1*,1* 7$%6 $0%,(17 $,5,1 &22/ $,5287 ; 81& 02817,1* +2/(6 $&&(66+2/(72>@ 2876,'(',$0(7(5'5$,1678% ; &/($1$%/(5(86$%/( $/80,180,1/(7),/7(5 237,21$/ $&&(663$1(/ 21/<)2581,76 :,7++($7(5 $&287/,1( ; ; ; &XWRXW'LPHQVLRQV Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. 36 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION *0RGHOV%78+U9:DWW3DUWLDO5HFHVV ; &22/,1*+($7,1* 7+(50267$7 $0%,(17 $,5287 ; $0%,(17 $,5,1 (1&/2685( $,5,1 (1&/2685( $,5287 32:(5 ,1387 02817,1* 678'6 3 ,1&/8'('02817,1**$6.(7.,772%($'+(5(' 727+,66,'(2)7+(02817,1*5$,/6%()25( ,167$//,1*$,5&21',7,21(572&$%,1(7 $&&(66+2/(72>@ 2876,'(',$0(7(5 '5$,1678% &/($1$%/(5(86$%/( $/80,180,1/(7),/7(5 237,21$/ $&&(663$1(/ 21/<)2581,76 :,7++($7(5 ; ; ; ; 02817,1* 5$,/287/,1( 7<3 ; 7<3 ; &XWRXW'LPHQVLRQV Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 37 Sealed Enclosure Cooling Air Conditioners 3 Sealed Enclosure Cooling Air Conditioners *0RGHO%78+U9%78+U9:DWW3DUWLDO5HFHVV 127( 02817,1**$6.(76833/,('1276+2:1 81,76LQ>PP@ &22/,1*+($7,1* 7+(50267$7 $0%,(17 $,5287 (1&/2685( $,5,1 32:(5 ,1/(7 02817,1* 678'6; $0%,(17 $,5,1 (1&/2685( $,5287 237,21$/ $&&(663$1(/ 21/<)25 81,76:,7+ +($7(5 &/($1$%/(5(86$%/( $/80,180,1/(7),/7(5 $&&(66+2/(72>@ 2876,'(',$0(7(5'5$,1678% ,1&/8'('02817,1**$6.(7.,772%($'+(5(' 727+,66,'(2)7+(02817,1*5$,/6%()25( ,167$//,1*$,5&21',7,21(572&$%,1(7 ; ; ; ; ; 7<3 02817,1* 5$,/ 287/,1( ; 7<3 &XWRXW'LPHQVLRQV Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. 38 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data G52 Models 8000/12000 BTU/Hr. (2300/3500 Watt) CATALOG NUMBER Indoor Model Indoor Model Stainless Steel Type 4X Indoor Model with Remote Access Control* Outdoor Model without Heat Pkg. Outdoor Model Partial Recessed Mount Outdoor Model without Heat Pkg. Stainless Steel Type 4X Outdoor Model with Heat Pkg. Outdoor Model with Heat Pkg. Stainless Steel Type 4X COOLING PERFORMANCE Nominal: BTU/Hr. Watts At 131 F/131 F (55 C/55 C): BTU/Hr. Watts At 95 F/95 F (35 C/35 C): BTU/Hr. Watts Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (ºF/ºC) Indoor Minimum (ºF/ºC) Outdoor Minimum (ºF/ºC) Airflow at 0 Static Pressure: Internal loop 50 Hz (CFM / m3/hr.) External loop 50 Hz (CFM / m3/hr.) Internal loop 60 Hz (CFM / m3/hr.) External loop 60 Hz (CFM / m3/hr.) Max. Heater W (Outdoor Models): ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (W) Max. Nominal Current (A) Starting Current (A) Agency Approvals G520816G050 G520816G051 G520816G060 G520816G100 G520816G101 G520816G102 G520816G150 G520816G151 G520826G050 G520826G051 G520826G060 G520826G100 G520826G101 G520826G102 G520826G150 G520826G151 G520846G050 G520846G051 G520846G060 G520846G100 G520846G101 G520846G102 G520846G150 G520846G151 G521216G050 G521216G051 G521216G060 G521216G100 G521216G101 G521216G102 G521216G150 G521216G151 G521226G050 G521226G051 G521226G060 G521226G100 G521226G101 G521226G102 G521226G150 G521226G151 G521246G050 G521246G051 G521246G060 G521246G100 G521246G101 G521246G102 G521246G150 G521246G151 8000 2300 8000 2300 8000 2300 12000 3500 12000 3500 12000 3500 7300/8200 2139/2403 7300/8200 2139/2403 8800/9800 2578/2871 12000/12500 3516/3662 12000/12500 3516/3662 11100/12000 3252/3516 6000/6800 1758/1992 R134a 24/680 6000/6800 1758/1992 R134a 24/680 7400/8200 2168/2402 R134a 24/680 9900/10700 2900/3135 R134a 38/1077 9900/10700 2900/3135 R134a 38/1077 9900/10700 2900/3135 R134a 38/1077 131/55 50/10 -40/-40 131/55 50/10 -40/-40 131/55 50/10 -40/-40 131/55 50/10 -40/-40 131/55 50/10 -40/-40 131/55 50/10 -40/-40 285/484 650/1104 310/527 700/1189 2000 285/484 650/1104 310/527 700/1189 2000 285/484 650/1104 310/527 700/1189 NA 287/487 635/1078 305/518 650/1104 2000 287/487 635/1078 305/518 650/1104 2000 287/487 635/1078 305/518 650/1104 NA 115 50/60 +/- 10% 1250/1415 11.2/12.3 48 230/208-230 50/60 +/- 10% 1250/1415 5.6/7.0-6.2 27 Power Input Description ENCLOSURE PROTECTION UL Type 3 400/460 3~ 50/60 +/- 10% 910/1106** 3.6/3.5 16 Type 12, 3R, 4 standard Type 4X Stainless steel optional IP56 internal loop IP34 external loop International Rating CONTROLLER Description Thermostat Location Digital Display Location: Indoor Models Outdoor Models Factory Thermostat Setting (F/C) SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Material Basic mechanical thermostat with digital display Enclosure side on all base models Ambient side Enclosure side 80/27 68 dB(A) Galvanized sheet metal standard Stainless steel optional RAL 7035 light-gray, semi-textured powder-coat paint standard Other colors available Finish ACCESSORIES Cleanable Re-usable Filter EASYSWAP Adaptor Plenum (GENESIS™ M52) UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) 400/460 3~ 115 230/208-230 50/60 50/60 50/60 +/- 10% +/- 10% +/- 10% 806/957** 2100/2427 1830/2130 3.1/3.2 16.1/21.0 9.1/10.6-9.5 16 57 38 cUL Listed CE GOST Others available upon request Terminal Block Aluminum mesh Part #101000103 Enables SPECTRACOOL to be mounted to a GENESIS M52 air conditioner cutout Catalog Number PLM52G52 128/58.1 128/58.1 52.69/1338 17.12/435 11.66/296 138/62.6 131/59.4 131/59.4 141/64.0 *Units with Remote Access Control utilize a digital controller and communicate via EtherNet/IP, Modbus TCP/IP and SNMP over ethernet or modbus RTU over USB. **Watts based on .65 power factor. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 39 Sealed Enclosure Cooling Air Conditioners Performance Curves for G52 Models 8000 BTU/Hr. (23 Watt) G52-08(1/2)6-GXXX Capacity Curves at 50 Hz Ambient Air In (°C) 30 40 20 50 15000 4395 Enclosure Air Temperature 3516 45 C 113 F 9000 2637 35 C 95 F 6000 1758 25 C 77 F 3000 879 0 68 77 86 95 104 Ambient Air In (°F) 113 G52-08(1/2)6-GXXX Capacity Curves at 60 Hz Ambient Air In (°C) 30 40 20 122 0 131 50 15000 4395 55 C 131 F 12000 Enclosure Air Temperature 3516 45 C 113 F 9000 2637 35 C 95 F 25 C 77 F 6000 1758 879 3000 0 68 40 Cooling Capacity (W) 55 C 131 F Cooling Capacity (W) Cooling Capacity (BTU/Hr.) 12000 Cooling Capacity (BTU/Hr.) 3 Sealed Enclosure Cooling Air Conditioners Cooling 77 86 95 104 Ambient Air In (°F) SUBJECT TO CHANGE WITHOUT NOTICE 113 122 0 131 EQUIPMENT PROTECTION Performance Curves for G52 Models 8000 BTU/Hr. (2300 Watt) G52-0846-GXXX Capacity Curves at 50 Hz Ambient Air In (°C) 30 40 20 50 15000 4395 55 C 131 F 3516 45 C 113 F 9000 2637 35 C 95 F 25 C 77 F 6000 Cooling Capacity (W) Cooling Capacity (BTU/Hr.) 12000 Enclosure Air Temperature 1758 3000 879 0 68 77 86 95 104 Ambient Air In (°F) 113 122 3 0 131 G52-0846-GXXX Capacity Curves at 60 Hz Ambient Air In (°C) 20 30 40 50 15000 4395 Cooling Capacity (BTU/Hr.) 12000 Enclosure Air Temperature 3516 45 C 113 F 35 C 95 F 9000 2637 25 C 77 F 6000 1758 3000 879 0 68 EQUIPMENT PROTECTION 77 86 95 104 Ambient Air In (°F) 113 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 122 Cooling Capacity (W) 55 C 131 F 0 131 Cooling 41 Sealed Enclosure Cooling Air Conditioners Performance Curves for G52 Models 12000 BTU/Hr. (3500 Watt) G52-12(1/2)6-GXXX Capacity Curve 50 Hz 20 Ambient Air In (°C) 40 30 50 5860 55 C 131 F 16000 Enclosure Air Temperature 4688 45 C 113 F 35 C 95 F 12000 3516 25 C 77 F Cooling Capacity (W) Cooling Capacity (BTU/Hr.) 20000 2344 8000 4000 68 77 86 95 104 Ambient Air In (°F) 113 122 1172 131 G52-12(1/2)6-GXXX Capacity Curve 60 Hz 20 30 Ambient Air In (°C) 40 50 20000 5860 16000 Enclosure Air Temperature 4688 45 C 113 F 35 C 95 F 12000 3516 25 C 77 F 8000 2344 4000 68 42 Cooling Cooling Capacity (W) 55 C 131 F Cooling Capacity (BTU/Hr.) 3 Sealed Enclosure Cooling Air Conditioners 77 86 95 104 Ambient Air In (°F) SUBJECT TO CHANGE WITHOUT NOTICE 113 122 1172 131 EQUIPMENT PROTECTION Performance Curves for G52 Models 12000 BTU/Hr. (3516 Watt) G52-1246-GXXX Capacity Curve 50 Hz 20 Ambient Air In (°C) 40 30 50 5274 55 C 131 F 14000 Enclosure Air Temperature 4102 45 C 113 F 35 C 95 F 10000 2930 25 C 77 F Cooling Capacity (W) Cooling Capacity (BTU/Hr.) 18000 1758 6000 3 2000 68 77 86 95 104 Ambient Air In (°F) 113 122 586 131 G52-1246-GXXX Capacity Curve 60 Hz 20 30 Ambient Air In (°C) 40 50 18000 5274 Enclosure Air Temperature 45 C 113 F 14000 4102 35 C 95 F 25 C 77 F 10000 2930 Cooling Capacity (W) Cooling Capacity (BTU/Hr.) 55 C 131 F 1758 6000 2000 68 EQUIPMENT PROTECTION 77 86 95 104 Ambient Air In (°F) 113 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 122 586 131 Cooling 43 Sealed Enclosure Cooling Air Conditioners 3 Sealed Enclosure Cooling Air Conditioners *0RGHOV%78+U:DWW 127( 02817,1**$6.(76833/,('1276+2:1 81,76LQ>PP@ (1&/2685( $,5,1 $0%,(17 $,5287 $0%,(17 $,5,1 7<3 5(029$%/( +$1*,1* 7$%6 32:(5 ,1/(7 >@ %78 >@ %78 &22/,1* +($7,1* 7+(50267$7 (1&/2685( $,5287 >@ %78 >@ %78 237,21$/$&&(663$1(/ 21/<)2581,76:,7++($7(5 &/($1$%/(5(86$%/( $/80,180,1/(7),/7(5 $&&(66+2/(>@ 2876,'(',$0(7(5 '5$,1678% ; ; ; ; ; ; ; ; ; ; ; ; 02817,1* +2/(6; ; ; ; $&287/,1( $&287/,1( &XWRXW'LPHQVLRQV 6WDQGDUG &XWRXW'LPHQVLRQV **** ****RQO\ Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. 44 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION *0RGHOV%78+U:DWWZLWK3DUWLDO5HFHVV 127( 02817,1**$6.(76833/,('1276+2:1 81,76LQ>PP@ $0%,(17 $,5287 (1&/2685( $,5,1 7<3 &22/,1*+($7,1* 7+(50267$7 32:(5 ,1/(7 7<3 >@ %78 >@ %78 $0%,(17 $,5,1 (1&/2685( $,5287 >@ %78 >@ %78 &/($1$%/(5(86$%/( $/80,180,1/(7),/7(5 237,21$/$&&(663$1(/ 21/<)2581,76:,7++($7(5 ,1&/8'('02817,1**$6.(7.,772%($'+(5('727+,66,'(2) 02817,1*5$,/6%()25(,167$//,1*$,5&21',7,21(572&$%,1(7 $&&(66+2/(72>@ 2876,'(',$0(7(5 '5$,1678% ; 3 ; ; ; ; ; 02817,1* 5$,/ 287/,1( &XWRXW'LPHQVLRQV Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 45 Sealed Enclosure Cooling Air Conditioners 3 Sealed Enclosure Cooling Air Conditioners Performance Data G57 Models 20000 BTU/Hr. (5861 Watt) CATALOG NUMBER Indoor Model Indoor Model Stainless Steel Type 4X Indoor Model with Remote Access Control* Outdoor Model without Heat Pkg. Outdoor Model Partial Recessed Mount Outdoor Model with Heat Pkg. Outdoor Model without Heat Pkg. Stainless Steel Type 4X Outdoor Model with Heat Pkg. Stainless Steel Type 4X COOLING PERFORMANCE Nominal: BTU/Hr. Watts At 131 F/131 F (55 C/55 C): BTU/Hr. (50/60 Hz) W (50/60 Hz) At 95 F/95 F (35 C/35 C): BTU/Hr. (50/60 Hz) W (50/60 Hz) Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (ºF/ºC) Indoor Minimum (ºF/ºC) Outdoor Minimum (ºF/ºC) Airflow at 0 Static Pressure: Internal loop 50 Hz (CFM / m3/hr.) External loop 50 Hz (CFM / m3/hr.) Internal loop 60 Hz (CFM / m3/hr.) External loop 60 Hz (CFM / m3/hr.) Max. Heater W (Outdoor Models) ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consuption (W at 50/60 Hz) Max. Nominal Current (A at 50/60 Hz) Starting Current (A) Agency Approvals 20000 5861 20000 5861 17500/19600 5129/5744 21400/23400 6272/6857 16000/18000 4689/5275 R407c 50/1417 19300/21400 5656/6272 R407c 48/1361 131/55 50/10 -40/-40 131/55 50/10 -40/-40 513/872 919/1562 587/998 1055/1794 3000 513/872 919/1562 587/998 1055/1794 3000 230/230 50/60 +/- 10% 4508/5106 19.6/22.2 63 400/460 3~ 50/60 +/- 10% 2400/3128 6.0/6.8 27 Type 12, 3R, 4 standard Type 4X stainless steel optional IP56 internal loop IP34 external loop International Rating Finish ACCESSORIES Cleanable Re-usable Filter EASYSWAP Adaptor Plenum (T-Series T53) G572046G050 G572046G051 G572046G060 G572046G100 G572046G101 G572046G150 G572046G102 G572046G151 cUL Listed CE GOST Others available upon request Terminal Block Power Input Description ENCLOSURE PROTECTION UL Type CONTROLLER Description Thermostat Location Digital Display Location: Indoor Models Outdoor Models Factory Thermostat Setting (ºF/ºC) SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Material G572026G050 G572026G051 G572026G060 G572026G100 G572026G101 G572026G150 G572026G102 G572026G151 Basic mechanical thermostat with digital display Enclosure side on all base models Ambient side Enclosure side 80/27 74.1 dB(A) Galvanized sheet metal standard Stainless steel optional RAL 7035 light-gray, semi-textured powder-coat paint standard Aluminum mesh part #101000103 BA Enables SPECTRACOOL to be mounted to a T-Series T53 air conditioner cutout part #57721601SP UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) 57.69/1465.4 20.87/530.1 15.28/388.1 197/89 *Units with Remote Access Control utilize a digital controller and communicate via EtherNet/IP, Modbus TCP/IP and SNMP over ethernet or modbus RTU over USB. 46 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Curves for G57 Models 20000 BTU/Hr. 20 30 G57-2026-GXXX Capacity Curves at 50 Hz Ambient Air In (°C) 40 50 36000 10549 55 C 131 F 28000 9377 Enclosure Air Temperature 8205 45 C 113 F 24000 7033 35 C 95 F 20000 5861 25 C 77 F 16000 Cooling Capacity (W) Cooling Capacity (BTU/Hr.) 32000 4689 3517 12000 3 8000 68 77 86 95 104 Ambient Air In (°F) 113 G57-2026-GXXX Capacity Curves at 60 Hz Ambient Air In (°C) 30 40 20 122 50 36000 10549 Enclosure Air Temperature 32000 55 C 131 F 28000 45 C 113 F 8205 24000 35 C 95 F 7033 20000 25 C 77 F 5861 9377 16000 4689 12000 3517 8000 68 EQUIPMENT PROTECTION 77 86 95 104 Ambient Air In (°F) 113 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 122 Cooling Capacity (W) Cooling Capacity (BTU/Hr.) 2345 131 2345 131 Cooling 47 Sealed Enclosure Cooling Air Conditioners Performance Curves for G57 Models 20000 BTU/Hr. G57-2046-GXXX Capacity Curves at 50 Hz 20 Ambient Air In (°C) 40 30 50 36000 10549 55 C 131 F 28000 9377 Enclosure Air Temperature 8205 45 C 113 F 24000 7033 35 C 95 F 20000 5861 25 C 77 F 16000 Cooling Capacity (W) Cooling Capacity (BTU/Hr.) 32000 4689 12000 3517 8000 68 77 86 95 104 Ambient Air In (°F) 113 122 2345 131 G57-2046-GXXX Capacity Curves at 60 Hz 20 30 Ambient Air In (°C) 40 50 36000 10549 55 C 131 F Enclosure Air Temperature 9377 45 C 113 F 28000 8205 35 C 95 F 24000 20000 7033 5861 25 C 77 F 16000 4689 12000 3517 8000 68 48 Cooling 77 86 95 104 Ambient Air In (°F) SUBJECT TO CHANGE WITHOUT NOTICE 113 122 Cooling Capacity (W) 32000 Cooling Capacity (BTU/Hr.) 3 Sealed Enclosure Cooling Air Conditioners 2345 131 EQUIPMENT PROTECTION *0RGHOV%78+U:DWW 127( 02817,1**$6.(76833/,('1276+2:1 81,76LQ>PP@ ; :$50 $,5287 (1&/2685( $,5,1 &22/,1* +($7,1* 7+(50267$7 ; 7<3 32:(5 ,1/(7 5(029$%/( +$1*,1* 7$%6 02817,1* +2/(6; $0%,(17 $,5,1 &22/ $,5287 3 237,21$/$&&(663$1(/ 21/<)2581,76:,7++($7(5 $&&(66+2/(72>@ 2876,'(',$0(7(5 '5$,1678% ; ; ; ; ; ; &/($1$%/(5(86$%/( $/80,180,1/(7),/7(5 ; ; ; ; ; ; ; ; ; ; $&287/,1( $&287/,1( ; &XWRXW'LPHQVLRQ 6WDQGDUG ; &XWRXW'LPHQVLRQV ****2QO\ Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 49 Sealed Enclosure Cooling Air Conditioners 3 Sealed Enclosure Cooling Air Conditioners *0RGHOV%78+U:DWW:LWK3DUWLDO5HFHVV 127( 02817,1**$6.(76833/,('1276+2:1 81,76LQ>PP@ :$50 $,5287 (1&/2685( $,5,1 7<3 &22/,1* +($7,1* 7+(50267$7 7<3 $0%,(17 $,5,1 02817,1* +2/(6 &22/ $,5287 &/($1$%/(5(86$%/( $/80,180,1/(7),/7(5 ,1&/8'('02817,1**$6.(7.,7 72%($'+(5('727+,66,'(2) 02817,1*5$,/6%()25(,167$//,1* $,5&21',7,21(572&$%,1(7 ; $&&(66+2/(72 >@2876,'( ',$0(7(5'5$,1 678% ; 237,21$/ $&&(663$1(/ 21/<)25 81,76:,7+ +($7(5 02817,1* 5$,/287/,1( ; ; ; ; &XWRXW'LPHQVLRQV Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. 50 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Notes 3 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 51 Sealed Enclosure Cooling Air Conditioners 3 Sealed Enclosure Cooling Air Conditioners SPECTRACOOL™ NARROW INDOOR/OUTDOOR FEATURES • • • • • • • • • • • • • • • • N43 11000 BTU/Hr. 3223 Watt N36 6000/8000 BTU/Hr. 1758/2344 Watt N28 4000 BTU/Hr. 1172 Watt • INDUSTRY STANDARDS UL/cUL Listed; Type 12, 3R, 4; 4X optional; File No. SA6453 CE IP 56 Internal Loop IP 34 on External Loop Telcordia GR-487 capable (Outdoor) arrow design accommodates 12-in. (300-mm) deep cabinets N Energy efficient rotary compressor R407c and R134a earth-friendly refrigerants Models for 115, 230 and 400/460 3-phase VAC power input UL Listed to save customers time and money with agency approvals Outdoor model operating temperature range from -40 F/-40 C to 131 F/55 C (125 F/52 C on N28 Series) Attractive industrial design with minimal use of visible fasteners Reliable mechanical thermostat on enclosure side of the unit; indoor Air Conditioner models include digital display on ambient side Galvanized sheet-metal cover for rugged factory and outdoor environments E asy-mount flanges for simple installation Cut-out adapter options for enclosures with GENESIS ® air conditioners enable users to easily transition to the new unit Dust-resistant condenser coil allows the unit to be run filterless in most applications Cleanable, reusable aluminum mesh filter protects coils for maximum cooling performance Mounting hardware, gaskets and user manual furnished with the unit Every unit functionally tested before shipping Standard Indoor Air Conditioner models also include: - Active condensate management with heater strip - Power-off relay for door switch and other system requirements - Malfunction switch Standard Outdoor Air Conditioner models also include: - Telcordia GR-487 capable - Corrosion-resistant components - Malfunction switch - Compressor heater - Head pressure control - 1300 W enclosure heater SPECIFICATIONS • Nominal cooling capacity: N28 4000 BTU/Hr. (1172 W) N36 6000 & 8000 BTU/Hr. (1758 and 2344 W) N43 11000 BTU/Hr. (3223 W) Outdoor model operating temperature range from -40 F/-40 C to 131 F/55 C (125 F/52 C on N28 Series) APPLICATION • • • • • FINISH Industrial automation Waste water treatment systems Package handling equipment S ecurity and defense systems • • AL 7035 light-gray, semi-textured powder-coat paint R O ther colors and textures available NOTES Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. 52 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data N28 4000 BTU/Hr. (1172 Watt) CATALOG NUMBER Indoor Model Indoor Model Stainless Steel Type 4X Indoor Model with Remote Access Control* Outdoor Model without Heat Pkg. Outdoor Model without Heat Pkg. Stainless Steel Type 4X Outdoor Model with Heat Pkg. Outdoor Model with Heat Pkg. Stainless Steel Type 4X COOLING PERFORMANCE Nominal: BTUs/Hr. Watts At 125 F / 125 F (50 C / 50 C): BTU/Hr. (50 / 60 Hz) Watts (50 / 60 Hz) At 95 F / 95 F (35 C / 35 C): BTU/Hr. (50 /60 Hz) Watts (50 / 60 Hz) Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F / °C) Minimum (°F / °C) Air Flow at 0 Static Pressure: Internal loop 50 Hz (CFM / M3/Hr) External loop 50 Hz (CFM / M3/Hr) Internal loop 60 Hz (CFM / M3/Hr) External loop 60 Hz (CFM / M3/Hr) Max. Heater W (Outdoor Models) ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (Watts at 50 / 60 Hz) Max. Nominal Current (Amps at 50 / 60 Hz) Starting Current (Amps) Agency Approvals N280416G050 N280416G051 N280416G060 N280416G100 N280416G102 N280416G150 N280416G151 N280426G050 N280426G051 N280426G060 N280426G100 N280426G102 N280426G150 N280426G151 N280425G050 N280425G051 N280425G060 N280425G100 N280425G102 N280425G150 N280425G151 N280446G050 N280446G051 N280446G060 N280446G100 N280446G102 N280446G150 N280446G151 3800 / 4000 1114 / 1172 4000 1172 3800 1114 4000 1172 3805 / 4162 1115 / 1220 4394 1288 3818 1119 4394 1288 3589 / 3974 1052 / 1165 R134a 11 / 312 3690 1081 R134a 11 / 312 3298 967 R134a 11 / 312 3690 1081 R134a 11 / 312 125/52 -40/-40 125/52 -40/-40 125/52 -40/-40 125/52 -40/-40 138 / 234 268 / 455 143 / 362 288 / 728 1300 N/A N/A 143 / 243 288 / 489 1300 138 / 234 268 / 455 N/A N/A 1300 N/A N/A 143 / 243 288 / 489 1300 110 / 115 50 / 60 +/-10% 1039 / 1191 11.6-11.2 40 230 60 +/-10% 1250 6.5 24.5 230 50 +/-10% 1111 5.8 24.5 460 60 +/-10% 1250 3.3 12.5 Power Input Description ENCLOSURE PROTECTION UL Type Type 12, 3R, 4 Standard Type 4X Stainless Steel Optional CONTROLLER Description Thermostat Location Factory Thermostat Setting (°F / °C) SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Material Basic Mechanical Thermostat Enclosure Side 80 / 27 66.1 dBA Finish ACCESSORIES EASYSWAP Adaptor Plenum (GENESIS™ M33) UNIT DIMENSIONS Height (in / mm) Width (in / mm) Depth (in / mm) Weight (lb / kg) cUL Listed CE Others available upon request Terminal Block 3 65.5 dBA 65.5 dBA 65.5 dBA Galvanized sheet metal standard Stainless steel optional RAL 7035 light-gray, semi-textured powder-coat paint standard Other colors available Enables SPECTRACOOL to be mounted to a GENESIS M33 air conditioner cutout Catalog Number PLM33N28 84/38 84/38 28 / 711.2 11.50 / 292.1 14.00 / 355.6 92/41.7 92/41.7 *Units with Remote Access Control utilize a digital controller and communicate via EtherNet/IP, Modbus TCP/IP and SNMP over ethernet or modbus RTU over USB. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 53 Sealed Enclosure Cooling Air Conditioners Performance Curves for N28 Models 4000 BTU/Hr. (1172 Watt) N28-0416-GXXX Capacity Curves at 50 Hz 20 Ambient Air In (°C) 40 30 50 1758 6000 Cooling Capacity (BTU/Hr.) Enclosure Air Temperature 1465 45 C 113 F 4000 1172 35 C 95 F 25 C 77 F 3000 879 Cooling Capacity (W) 51 C 124 F 5000 586 2000 1000 68 77 86 95 104 Ambient Air In (°F) 113 122 293 131 N28-0416-GXXX Capacity Curves at 60 Hz 20 30 Ambient Air In (°C) 40 50 6000 1758 Enclosure Air Temperature 1465 45 C 113 F 35 C 95 F 4000 1172 25 C 77 F 3000 879 2000 586 1000 68 54 Cooling 77 86 95 104 Ambient Air In (°F) SUBJECT TO CHANGE WITHOUT NOTICE 113 122 Cooling Capacity (W) 51 C 124 F 5000 Cooling Capacity (BTU/Hr.) 3 Sealed Enclosure Cooling Air Conditioners 293 131 EQUIPMENT PROTECTION Performance Curves for N28 Models 4000 BTU/Hr. (1172 Watt) N28-0426-GXXX Capacity Curves at 50 Hz 20 Ambient Air In (°C) 40 30 50 7000 2051 1758 51 C 124 F 5000 Enclosure Air Temperature 1465 45 C 113 F 4000 35 C 95 F 1172 3000 25 C 77 F 879 2000 Cooling Capacity (W) Cooling Capacity (BTU/Hr.) 6000 586 1000 68 77 86 95 104 Ambient Air In (°F) 113 122 293 131 3 N28-0426-GXXX Capacity Curves at 60 Hz 20 30 Ambient Air In (°C) 40 50 7000 2051 Cooling Capacity (BTU/Hr.) Enclosure Air Temperature 1758 45 C 113 F 5000 1465 35 C 95 F 4000 1172 25 C 77 F 3000 Cooling Capacity (W) 51 C 124 F 6000 879 2000 586 1000 68 EQUIPMENT PROTECTION 77 86 95 104 Ambient Air In (°F) 113 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 122 293 131 Cooling 55 Sealed Enclosure Cooling Air Conditioners 3 Sealed Enclosure Cooling Air Conditioners N28 Models 4000 BTU/Hr. (1172 Watt) >@ >@ >@ >@ >@ +($7,1*7 67$7 237,21$/ >@ :$50 $,5287 5(029$%/( +$1*,1*7$%6 &22/ $,5287 >@ >@ (1&/2685( $,5,1 $0%,(17 $,5,1 &22/,1*7 67$7 >@ >@ >@ >@ >@ >@ >@ 81& 02817,1* +2/(6 &/($1$%/(5(86$%/( $/80,180,1/(7$,5),/7(5 38//6287)5217 $&&(66+2/(72 >@2876,'( ',$0(7(5'5$,1678% >@ >@ >@ >@ 237,21$/$&&(663$1(/ 21/<)2581,76 :,7++($7(5 >@ >@ >@ >@ >@ >@ >@ >@ >@ >@ >@ >@ >@ >@ >@ Cutout Dimensions Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. 56 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data N36 6000/8000 BTU/Hr. (1758/2344 Watt) CATALOG NUMBER Indoor Model Indoor Model Stainless Steel Type 4X Indoor Model with Remote Access Control* Outdoor Model without Heat Pkg. Outdoor Model without Heat Pkg. Stainless Steel Type 4X Outdoor Model with Heat Pkg. Outdoor Model with Heat Pkg. Stainless Steel Type 4X COOLING PERFORMANCE Nominal: BTU/Hr. Watts At 131 F / 131 F (55 C / 55 C): BTU/Hr. (50 / 60 Hz) Watts (50 / 60 Hz) At 95 F / 95 F (35 C / 35 C): BTU/Hr. (50 /60 Hz) Watts (50 / 60 Hz) Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F / °C) Minimum (°F / °C) Air Flow at 0 Static Pressure: Internal loop 50 Hz (CFM / M3/Hr.) External loop 50 Hz (CFM / M3/Hr.) Internal loop 60 Hz (CFM / M3/Hr.) External loop 60 Hz (CFM / M3/Hr.) Max. Heater W (Outdoor Models) ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (Watts at 50 / 60 Hz) Max. Nominal Current (Amps at 50 / 60 Hz) Starting Current (Amps) Agency Approvals N360616G050 N360616G051 N360616G060 N360616G100 N360616G102 N360626G050 N360626G051 N360626G060 N360626G100 N360626G102 N360646G050 N360646G051 N360646G060 N360646G100 N360646G102 N360816G050 N360816G051 N360816G060 N360816G100 N360816G102 N360826G050 N360826G051 N360826G060 N360826G100 N360826G102 N360846G050 N360846G051 N360846G060 N360846G100 N360846G102 N360616G150 N360616G151 N360626G150 N360626G151 N360646G150 N360646G151 N360816G150 N360816G151 N360826G150 N360826G151 N360846G150 N360846G151 5400 / 6000 1581 / 1757 5400 / 6000 1581 / 1757 5400 / 6000 1581 / 1757 8250 / 8500 2416 / 2489 8250 / 8500 2313 / 2635 8250 / 8500 2284 / 2401 5585 / 6180 1637 / 1811 5469 / 5965 1603 / 1748 5300 / 6089 1553 / 1785 8213 / 8453 2405 / 2475 7874 / 8063 2306 / 2361 7777 / 8166 2277 / 2391 4909 / 5485 1439 / 1607 R134a 20 / 567 5159 / 5621 1512 / 1647 R134a 22 / 624 5572 / 6026 1633 / 1766 R134a 16 / 454 7028 / 7626 2058 / 2233 R134a 36 / 1021 6660 / 7411 1950 / 2170 R134a 36 / 1021 6877 / 7525 2014 / 2203 R134a 36 / 1021 131 / 55 -40 / -40 131 / 55 -40 / -40 131 / 55 -40 / -40 131 / 55 -40 / -40 131 / 55 -40 / -40 131 / 55 -40 / -40 251 / 426 284 / 483 261 / 443 311 / 528 1300 250 / 425 338 / 574 261 / 443 356 / 605 1300 250 / 425 338 / 574 261 / 443 356 / 605 1300 250 / 425 313 / 532 263 / 447 338 / 574 1300 245 / 416 347 / 589 258 / 439 382 / 648 1300 243 / 413 365 / 620 254 / 432 394 / 669 1300 115 50 / 60 +/-10% 911 / 1108 9.1 / 10.1 39.2 230 50 / 60 +/-10% 908 / 1073 4.5 / 4.7 23 230 50 / 60 +/-10% 1265 / 1403 5.5/6.1 27 400 / 460 3~ 50 / 60 +/-10% 572 / 628 2.9/3.0 16 66.0 dBA 66.0 dBA Power Input Description ENCLOSURE PROTECTION UL Type 3 Type 12, 3R, 4 Standard Type 4X Stainless Steel Optional CONTROLLER Description Thermostat Location Factory Thermostat Setting (°F / °C) SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Material Basic Mechanical Thermostat Enclosure Side 80 / 27 66.9 dBA ACCESSORIES EASYSWAP Adaptor Plenum (GENESIS™ M36) 66.7 dBA 68.2 dBA 66.0 dBA Galvanized sheet metal standard Stainless steel optional RAL 7035 light-gray, semi-textured powder-coat paint standard Other colors available Finish UNIT DIMENSIONS Height (in. / mm) Width (in. / mm) Depth (in. / mm) Weight (lb. / kg) 400 / 460 3~ 115 50 / 60 50 / 60 +/-10% +/-10% 697 / 895 1334 / 1530 1.59 / 1.69 11.6 / 13.3 8.1 48.3 cUL Listed CE Others available upon request Terminal Block Enables SPECTRACOOL to be mounted to a GENESIS M36 air conditioner cutout Catalog Number PLM36N36 100 / 45 100 / 45 36.00 / 914.4 11.50 / 292.1 14.00 / 355.6 104 / 47 106 / 48 106 / 48 114 / 52 *Units with Remote Access Control utilize a digital controller and communicate via EtherNet/IP, Modbus TCP/IP and SNMP over ethernet or modbus RTU over USB. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 57 Sealed Enclosure Cooling Air Conditioners Performance Curves for N36 Models 6000 BTU/Hr. (1758 Watt) N36-0616-GXXX Capacity Curves at 50 Hz Ambient Air In (°C) 30 40 8000 Enclosure Air Temperat 2344 45 C 113 F 6000 35 C 95 F 1758 25 C 77 F 4000 2000 68 1172 77 6000 95 104 Ambient Air In (°F) 113 122 50 586 131 2930 Enclosure Air Temperat 55 C 131 F 8000 86 N36-0616-GXXX Capacity Curves at 60 Hz Ambient Air In (°C) 30 40 20 10000 45 C 113 F 2344 35 C 95 F 1758 25 C 77 F 4000 2000 68 58 2930 Cooling Cooling Capacity (W) 55 C 131 F 50 Cooling Capacity (W) Cooling Capacity (BTU/Hr.) 20 10000 Cooling Capacity (BTU/Hr.) 3 Sealed Enclosure Cooling Air Conditioners 1172 77 86 95 104 Ambient Air In (°F) SUBJECT TO CHANGE WITHOUT NOTICE 113 122 586 131 EQUIPMENT PROTECTION Performance Curves for N36 Models 6000 BTU/Hr. (1758 Watt) 20 30 N36-0626-GXXX Capacity Curves at 50 Hz Ambient Air In (°C) 40 50 2930 10000 55 C 131 F Enclosure Air Temperature Cooling Capacity (BTU/Hr.) 45 C 113 F 35 C 95 F 6000 1758 25 C 77 F 4000 1172 Cooling Capacity (W) 2344 8000 586 2000 0 68 77 86 95 104 Ambient Air In (°F) 113 122 0 131 3 N36-0626-GXXX Capacity Curves at 60 Hz 20 30 Ambient Air In (°C) 40 50 10000 2930 55 C 131 F 45 C 113 F 2344 35 C 95 F 6000 1758 25 C 77 F 4000 1172 2000 586 0 68 EQUIPMENT PROTECTION 77 86 95 104 Ambient Air In (°F) 113 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 122 Cooling Capacity (W) 8000 Cooling Capacity (BTU/Hr.) Enclosure Air Temperature 0 131 Cooling 59 Sealed Enclosure Cooling Air Conditioners Performance Curves for N36 Models 6000 BTU/Hr. (1758 Watt) N36-0646-GXXX Capacity Curves at 50 Hz 20 Ambient Air In (°C) 40 30 50 3516 55 C 131 F 9000 Enclosure Air Temperature 2637 45 C 113 F 35 C 95 F 6000 1758 25 C 77 F Cooling Capacity (W) Cooling Capacity (BTU/Hr.) 12000 879 3000 0 68 77 86 95 104 Ambient Air In (°F) 113 122 0 131 N36-0646-GXXX Capacity Curves at 60 Hz 20 30 Ambient Air In (°C) 40 50 12000 3516 9000 Enclosure Air Temperature 2637 45 C 113 F 35 C 95 F 6000 1758 25 C 77 F 3000 879 0 68 60 Cooling Cooling Capacity (W) 55 C 131 F Cooling Capacity (BTU/Hr.) 3 Sealed Enclosure Cooling Air Conditioners 77 86 95 104 Ambient Air In (°F) SUBJECT TO CHANGE WITHOUT NOTICE 113 122 0 131 EQUIPMENT PROTECTION Performance Curves for N36 Models 8000 BTU/Hr. (2344 Watt) N36-0816-GXXX Capacity Curves at 50 Hz Ambient Air In (°C) 30 40 20 50 4102 12000 55 C 131 F 10000 45 C 113 F Enclosure Air Temperature 3516 2930 8000 35 C 95 F 2344 6000 25 C 77 F 1758 Cooling Capacity (W) Cooling Capacity (BTU/Hr.) 14000 1172 4000 2000 68 77 86 95 104 Ambient Air In (°F) 113 122 586 131 3 N36-0816-GXXX Capacity Curves at 60 Hz 20 30 Ambient Air In (°C) 40 50 4102 12000 55 C 131 F 10000 45 C 113 F Enclosure Air Temperature 3516 2930 35 C 95 F 8000 2344 25 C 77 F 6000 Cooling Capacity (W) Cooling Capacity (BTU/Hr.) 14000 1758 1172 4000 2000 68 EQUIPMENT PROTECTION 77 86 95 104 Ambient Air In (°F) 113 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 122 586 131 Cooling 61 Sealed Enclosure Cooling Air Conditioners Performance Curves for N36 Models 8000 BTU/Hr. (2344 Watt) N36-0826-GXXX Capacity Curves at 50 Hz 20 Ambient Air In (°C) 40 30 50 14000 4102 55 C 131 F 10000 3516 Enclosure Air Temperature 2930 45 C 113 F 8000 35 C 95 F 2344 6000 25 C 77 F 1758 4000 Cooling Capacity (W) Cooling Capacity (BTU/Hr.) 12000 1172 2000 68 77 86 95 104 Ambient Air In (°F) 113 122 586 131 N36-0826-GXXX Capacity Curves at 60 Hz 20 30 Ambient Air In (°C) 40 50 14000 4102 12000 55 C 131 F 10000 45 C 113 F Enclosure Air Temperature 3516 2930 35 C 95 F 8000 2344 25 C 77 F 6000 1758 4000 1172 2000 68 62 Cooling Cooling Capacity (W) Cooling Capacity (BTU/Hr.) 3 Sealed Enclosure Cooling Air Conditioners 77 86 95 104 Ambient Air In (°F) SUBJECT TO CHANGE WITHOUT NOTICE 113 122 586 131 EQUIPMENT PROTECTION Performance Curves for N36 Models 8000 BTU/Hr. (2344 Watt) 20 30 N36-0846-GXXX Capacity Curves at 50 Hz Ambient Air In (°C) 40 50 12000 3516 Enclosure Air Temperature 55 C 131 F 8000 2344 35 C 95 F 25 C 77 F 6000 1758 4000 1172 2000 68 77 86 95 104 Ambient Air In (°F) 113 N36-0846-GXXX Capacity Curves at 60 Hz Ambient Air In (°C) 30 40 20 12000 122 3 50 Enclosure Air Temperature 45 C 113 F 2930 35 C 95 F 8000 586 131 3516 55 C 131 F 10000 Cooling Capacity (BTU/Hr.) Cooling Capacity (W) 2930 45 C 113 F 2344 25 C 77 F 6000 1758 4000 1172 2000 68 EQUIPMENT PROTECTION 77 86 95 104 Ambient Air In (°F) 113 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 122 Cooling Capacity (W) Cooling Capacity (BTU/Hr.) 10000 586 131 Cooling 63 Sealed Enclosure Cooling Air Conditioners 3 Sealed Enclosure Cooling Air Conditioners N36 6000/8000 BTU/Hr. (1758/2344 Watt) >@ >@ >@ >@ >@ +($77+(50267$7 237,21$/ >@ &22/7+(50267$7 >@ >@ (1&/65 $,5,1 5(029$%/( +$1*,1* 7$%6 $0%,(17 $,5,1 32:(5 ,1387 >@ :$50 $,5287 &/($1$%/(5(86$%/( $/80,180,1/(7),/7(5 38//6287)5217 &22/ $,5287 >@ >@ ; 81& 02817,1* +2/(6; >@ ; >@ ; >@ >@ $&&(66+2/(72 >@2876,'( ',$0(7(5'5$,1678% ; >@ >@ >@ >@ ; ; >@ 237,21$/$&&(663$1(/ 21/<)2581,76:,7++($7(5 >@ >@ ; ; >@ ; >@ >@ >@ ; >@ ; >@ ; >@ ; >@ ; >@ ; >@ Cutout Dimensions Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. 64 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data N43 11000 BTU/Hr. (3223 Watt) CATALOG NUMBER Indoor Model Indoor Model Stainless Steel Type 4X Indoor Model with Remote Access Control* Outdoor Model without Heat Pkg. Outdoor Model without Heat Pkg. Stainless Steel Type 4X Outdoor Model with Heat Pkg. Outdoor Model with Heat Pkg. Stainless Steel Type 4X COOLING PERFORMANCE Nominal: BTU/Hr. Watts At 131 F / 131 F (55 C / 55 C): BTU/Hr. (50 / 60 Hz) Watts (50 / 60 Hz) At 95 F / 95 F (35 C / 35 C): BTU/Hr. (50 /60 Hz) Watts (50 / 60 Hz) Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F / °C) Minimum (°F / °C) Air Flow at 0 Static Pressure: Internal loop 50 Hz (CFM / M3/Hr) External loop 50 Hz (CFM / M3/Hr) Internal loop 60 Hz (CFM / M3/Hr) External loop 60 Hz (CFM / M3/Hr) Max. Heater W (Outdoor Models) ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (Watts at 50 / 60 Hz) Max. Nominal Current (Amps at 50 / 60 Hz) Starting Current (Amps) Agency Approvals N431216G050 N431216G051 N431216G060 N431216G100 N431216G102 N431216G150 N431216G151 N431226G050 N431226G051 N431226G060 N431226G100 N431226G102 N431226G150 N431226G151 N431246G050 N431246G051 N431246G060 N431246G100 N431246G102 N431246G150 N431246G151 10400 / 11000 3047 / 3223 10400 / 11000 2900 / 3223 10400 / 11000 2900 / 3223 10588 / 11180 3103 / 3277 9946 / 11052 2915 / 3239 10048 / 10797 2945 / 3164 9475 / 10023 2777 / 2937 R134a 36 / 1021 8967 / 9644 2628 / 2826 R134a 38 / 1077 8587 / 9559 2517 / 2801 R134a 41 / 1162 131 / 55 -40 / -40 131 / 55 -40 / -40 131 / 55 -40 / -40 239 / 406 494 / 839 250 / 425 528 / 897 1300 259 / 440 489 / 831 267 / 454 525 / 892 1300 254 / 432 341 / 579 260 / 442 564 / 958 1300 115 50 / 60 +/-10% 1802 / 2446 16.6 / 22.0 57 230 50 / 60 +/-10% 1802 / 2446 8.7 / 9.1 38 cUL Listed CE Others available upon request Terminal Block 400 / 460 3~ 50 / 60 +/-10% 1283 / 1644 3.1 / 3.3 16 Power Input Description ENCLOSURE PROTECTION UL Type CONTROLLER Description Thermostat Location Factory Thermostat Setting (°F / °C) SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Material Finish UNIT DIMENSIONS Height (in / mm) Width (in / mm) Depth (in / mm) Weight (lb / kg) 3 Type 12, 3R, 4 Standard Type 4X Stainless Steel Optional Basic Mechanical Thermostat Enclosure Side 80 / 27 68.4 dBA 68.4 dBA 69.6 dBA Galvanized sheet metal standard Stainless steel optional RAL 7035 light-gray, semi-textured powder-coat paint standard Other colors available 127/57.6 43.00 / 1092.2 11.50 / 292.1 14.00 / 355.6 127/57.6 138/62.6 *Units with Remote Access Control utilize a digital controller and communicate via EtherNet/IP, Modbus TCP/IP and SNMP over ethernet or modbus RTU over USB. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 65 Sealed Enclosure Cooling Air Conditioners Performance Curves for N43 Models 11000 BTU/Hr. (3223 Watt) N43-1216-GXXX Capacity Curves at 50 Hz 20 Ambient Air In (°C) 40 30 50 16000 4688 14000 55 C 131 F 4102 12000 45 C 113 F 3516 10000 35 C 95 F 2930 25 C 77 F 8000 Cooling Capacity (W) Cooling Capacity (BTU/Hr.) Enclosure Air Temperature 2344 6000 1758 4000 68 77 86 95 104 Ambient Air In (°F) 113 122 1172 131 N43-1216-GXXX Capacity Curves at 60 Hz 20 30 Ambient Air In (°C) 40 50 16000 4688 55 C 131 F Enclosure Air Temperature 14000 4102 45 C 113 F 12000 3516 35 C 95 F 10000 2930 25 C 77 F 8000 2344 6000 1758 4000 68 66 Cooling 77 86 95 104 Ambient Air In (°F) SUBJECT TO CHANGE WITHOUT NOTICE 113 122 Cooling Capacity (W) Cooling Capacity (BTU/Hr.) 3 Sealed Enclosure Cooling Air Conditioners 1172 131 EQUIPMENT PROTECTION Performance Curves for N43 Models 11000 BTU/Hr. (3223 Watt) 20 30 N43-1226-GXXX Capacity Curves at 50 Hz Ambient Air In (°C) 40 50 16000 4688 14000 4102 12000 45 C 113 F 3516 10000 35 C 95 F 2930 8000 25 C 77 F 2344 6000 Cooling Capacity (W) Cooling Capacity (BTU/Hr.) Enclosure Air Temperature 55 C 131 F 1758 4000 68 77 20 86 30 95 104 Ambient Air In (°F) 113 N43-1226-GXXX Capacity Curves at 60 Hz Ambient Air In (°C) 40 122 1172 131 3 50 16000 4688 Enclosure Air Temperature 55 C 131 F 4102 45 C 113 F 12000 3516 35 C 95 F 10000 2930 25 C 77 F 8000 2344 6000 1758 4000 68 EQUIPMENT PROTECTION 77 86 95 104 Ambient Air In (°F) 113 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 122 Cooling Capacity (W) Cooling Capacity (BTU/Hr.) 14000 1172 131 Cooling 67 Sealed Enclosure Cooling Air Conditioners Performance Curves for N43 Models 11000 BTU/Hr. (3223 Watt) N43-1246-GXXX Capacity Curves at 50 Hz Ambient Air In (°C) 30 40 20 50 15000 4395 3516 45 C 113 F 35 C 95 F 9000 2637 25 C 77 F 6000 1758 3000 68 77 86 95 104 Ambient Air In (°F) 113 N43-1246-GXXX Capacity Curves at 60 Hz Ambient Air In (°C) 30 40 20 122 879 131 50 15000 4395 Enclosure Air Temperature 55 C 131 F 45 C 113 F 12000 3516 35 C 95 F 9000 2637 25 C 77 F 6000 1758 3000 68 68 Cooling Cooling Capacity (W) 12000 Enclosure Air Temperature Cooling Capacity (W) Cooling Capacity (BTU/Hr.) 55 C 131 F Cooling Capacity (BTU/Hr.) 3 Sealed Enclosure Cooling Air Conditioners 77 86 95 104 Ambient Air In (°F) SUBJECT TO CHANGE WITHOUT NOTICE 113 122 879 131 EQUIPMENT PROTECTION N43 12000 BTU/Hr. (3516 Watt) >@ >@ >@ >@ +($7767$7 237,21$/ >@ ; >@ >@ &22/767$7 >@ >@ ; (1&/65 $,5,1 $0%,(17 $,5,1 5(029$%/( +$1*,1* 7$%6 :$50 $,5287 >@ ; 32:(5 ,1387 >@ ; >@ &22/ $,5287 &/($1$%/(5(86$%/( $/80,180,1/(7),/7(5 38//6287)5217 >@ >@ >@ >@ >@ >@ 81& 02817,1* +2/(6; >@ 3 237,21$/$&&(663$1(/ 21/<)2581,76:,7++($7(5 ; >@ >@ $&&(66+2/(72 >@2''5$,1678% >@ ; >@ >@ ; >@ >@ >@ ; ; >@ ; >@ >@ ; >@ >@ ; ; >@ >@ ; >@ ; ; >@ CUTOUT INSTRUCTIONS Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 69 Sealed Enclosure Cooling Air Conditioners 3 Sealed Enclosure Cooling Air Conditioners SPECTRACOOL™ COMPACT INDOOR N17 115/230 V Volt l 1000 BTU/Hr. 293 Watt N17 460 Volt V l 1800 BTU/Hr. 527 Watt INDUSTRY STANDARDS • UL/cUL Listed; Type 12; File No. SA6453 • CE IP 54 Internal Loop IP 34 on External Loop • • • APPLICATION • • • Industrial automation Package handling equipment S ecurity and defense systems FEATURES • • • • • • • • • 70 arrow design accommodates 12-in. deep cabinets N R134a earth-friendly refrigerants Models for 115, 230 and 400/460 VAC power input UL Listed to save customers time and money with agency approvals Attractive industrial design with minimal use of visible fasteners Reliable mechanical thermostat is located behind the cover of the unit; Air Conditioner models include digital display on ambient side Galvanized sheet-metal cover for rugged factory environments E asy-mount flanges for simple installation Cut-out adapter options for enclosures with GENESIS ® air conditioners enable users to easily transition to the new unit Cooling ust-resistant condenser coil allows the unit to be run filterless D in most applications Cleanable, reusable aluminum mesh filter protects coils for maximum cooling performance Mounting hardware, gaskets and user manual furnished with the unit Every unit functionally tested before shipping Standard Indoor Air Conditioner models also include: - Active condensate management - Power-off relay for door switch and other system requirements - Malfunction switch SPECIFICATIONS • • Nominal cooling capacity: N17 1000 BTU/Hr. (293 W) N17 1800 BTU/Hr. (527 W) Operating temperature range from 50 F/10 C to 125 F/52 C FINISH • • AL 7035 light-gray, semi-textured powder-coat paint R O ther colors and textures available NOTES Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data N17 Models 1000/1800 BTU/Hr. (300/527 Watt) CATALOG NUMBER Indoor Model Indoor Model with Remote Access Control* COOLING PERFORMANCE Nominal: BTU/Hr. Watts Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F/°C) Minimum (°F/°C) Airflow at 0 Static Pressure: Internal loop 50 Hz (CFM / m3/hr.) External loop 50 Hz (CFM / m3/hr.) Internal loop 60 Hz (CFM / m3/hr.) External loop 60 Hz (CFM / m3/hr.) ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (W at 50/60 Hz) Max. Nominal Current (A at 50/60 Hz) Starting Current (A) Agency Approvals N170116G010 N170116G020 N170126G010 N170126G020 N170146G010 N170146G020 N170216G010 N170216G020 N170226G010 N170226G020 N170246G010 N170246G020 908/1025 266/300 R-134a 5/142 908/1025 266/300 R-134a 5/142 908/1025 266/300 R-134a 5/142 1500/1800 440/527 R-134a 5.5/156 1500/1800 440/527 R-134a 5.5/156 1500/1800 440/527 R-134a 5.5/156 125/52 50/10 125/52 50/10 125/52 50/10 125/52 50/10 125/52 50/10 125/52 50/10 57/97 96/163 67/114 114/194 57/97 96/163 67/114 114/194 57/97 96/163 67/114 114/194 61/104 98/167 72/122 118/200 61/104 98/167 72/122 118/200 61/104 98/167 72/122 118/200 110/115 50/60 +/- 10% 337/356 4.4/3.9 18 220/208-230 50/60 +/- 10% 375/407 2.3/2.1 8.5 220/208-230 50/60 +/- 10% 639/667 4.0/3.5 14.4 400/460 50/60 +/- 10% 543/603 2.0/2.0 7.2 Power Input Description ENCLOSURE PROTECTION UL Type IP CONTROLLER (...G010 Models) Thermostat Location Factory Thermostat Setting (°F/°C) CONTROLLER (...G020 Models) Thermostat Location Factory Thermostat Setting (°F/°C) SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Material Finish Type 12 IP 54 3 Behind Cover, Right Side 80/27 Ambient Side 80/27 65.0 dBA ACCESSORIES EASYSWAP Adaptor Plenum (GENESIS™ M13) UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) 400/460 110/115 50/60 50/60 +/- 10% +/- 10% 345/376 642/728 1.2/1.2 7.0/7.1 4.25 28 UL/cUL Listed CE Terminal Block Galvanized sheet metal standard RAL 7035 light-gray, semi-textured powder-coat paint standard Other colors available Enables SPECTRACOOL to be mounted to a GENESIS M13 air conditioner cutout Catalog Number PLM13N17 NOTE: EASYSWAP adaptor plenum not required for M17. It is the same cutout as N17. 17.64/448.1 12.0/304.8 8.4/213.4 50/23 17.64/448.1 12.0/304.8 8.4/213.4 50/23 22.14/562.4 12.0/304.8 8.4/213.4 66/30 17.64/448.1 12.0/304.8 8.4/213.4 54/25 17.64/448.1 12.0/304.8 8.4/213.4 54/25 22.14/562.4 12.0/304.8 8.4/213.4 73/33 *Units with Remote Access Control utilize a digital controller and communicate via EtherNet/IP, Modbus TCP/IP and SNMP over ethernet or modbus RTU over USB. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 71 Sealed Enclosure Cooling Air Conditioners Performance Curves for N17 Models 1000 BTU/Hr. (293 Watt) N17-0116-GXXX Capacity Curves at 50 Hz Ambient Air In (°C) 20 26 33 39 45 52 Cooling Capacity (BTU/Hr.) 1500 586 439 Enclosure Air Temperature 52 C 125 F 1000 293 45 C 113 F 35 C 95 F 500 Cooling Capacity (W) 2000 146 25 C 77 F 0 68 79 91 102 114 0 125 45 52 Ambient Air In (°F) N17-0116-GXXX Capacity Curves at 60 Hz Ambient Air In (°C) 20 26 33 39 2000 586 1500 439 Enclosure Air Temperature 52 C 126 F 1000 293 45 C 113 F 35 C 95 F 500 Cooling Capacity (W) Cooling Capacity (BTU/Hr) 3 Sealed Enclosure Cooling Air Conditioners 146 25 C 77 F 0 68 79 91 102 114 0 125 Ambient Air In (°F) 72 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Curves for N17 Models 1000/2000 BTU/Hr. (293/585 Watt) N17-01(2/4)6-GXXX Capacity Curves at 50 Hz Ambient Air In (°C) 20 26 33 39 45 52 2500 732 Cooling Capacity (BTU/Hr) 2000 Enclosure Air Temperature 586 45 C 113 F 1500 35 C 95 F 439 1000 25 C 77 F 293 500 Cooling Capacity (W) 52 C 126 F 146 3 0 68 79 91 102 114 0 125 45 52 Ambient Air In (°F) N17-01(2/4)6-GXXX Capacity Curves at 60 Hz Ambient Air In (°C) 20 26 33 39 2500 732 2000 45 C 113 F 586 1500 35 C 95 F 439 1000 25 C 77 F 293 500 Cooling Capacity (W) Cooling Capacity (BTU/Hr) 52 C 126 F Enclosure Air Temperature 146 0 68 79 91 102 114 0 125 Ambient Air In (°F) EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 73 Sealed Enclosure Cooling Air Conditioners Performance Curves for N17 Models 1000 BTU/Hr. (293 Watt) N17-0216-GXXX Capacity Curves at 50 Hz Ambient Air In (°C) 20 26 33 39 45 52 3000 878 52 C 126 F Enclosure Air Temperature 732 45 C 113 F 2000 586 35 C 95 F 1500 439 25 C 77 F 1000 293 500 146 0 68 79 91 102 114 0 125 45 52 Cooling Capacity (W) Cooling Capacity (BTU/Hr) 2500 Ambient Air In (°F) N17-0216-GXXX Capacity Curves at 60 Hz Ambient Air In (°C) 20 26 33 39 3500 1025 3000 52 C 126 F 2500 45 C 113 F Enclosure Air Temperature 878 732 35 C 95 F 2000 586 25 C 77 F 1500 439 1000 293 500 146 0 68 79 91 102 114 Cooling Capacity (W) Cooling Capacity (BTU/Hr) 3 Sealed Enclosure Cooling Air Conditioners 0 125 Ambient Air In (°F) 74 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Curves for N17 Models 1000/2000 BTU/Hr. (293/585 Watt) N17-02(2/4)6-GXXX Capacity Curves at 50 Hz Ambient Air In (°C) 20 26 33 39 45 52 878 3000 732 45 C 113 F 2000 586 35 C 95 F 1500 439 25 C 77 F 1000 293 500 146 Cooling Capacity (W) Cooling Capacity (BTU/Hr) 2500 52 C 126 F Enclosure Air Temperature 3 114 0 125 45 52 0 68 79 91 102 Ambient Air In (°F) N17-02(2/4)6-GXXX Capacity Curves at 60 Hz Ambient Air In (°C) 20 26 33 39 1025 3500 Cooling Capacity (BTU/Hr) 3000 Enclosure Air Temperature 878 45 C 113 F 2500 732 35 C 95 F 2000 586 25 C 77 F 1500 439 1000 293 500 146 0 68 79 91 102 114 Cooling Capacity (W) 52 C 126 F 0 125 Ambient Air In (°F) EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 75 Sealed Enclosure Cooling Air Conditioners 3 Sealed Enclosure Cooling Air Conditioners N17 Models 1000/1800 BTU/Hr. (300/527 Watt) -%2; :$50 $,5287 (1&/2685( $,5,1 -%2;32:(5&211(&7,216 %(+,1'5(029$%/(&29(5 $0%,(17 $,5,1 5(029$%/( +$1*,1* %5$&.(7 &22/ $,5287 ;)05%2; &21'(16$7( '5$,1 81& 02817,1* 75$16)250(5 921/< &/($1$%/(5(86$%/( $/80,180,1/(7),/7(5 6/,'(62876,'( +$1*,1* 7$%6 ; 675$,15(/,())25 32:(5:,5,1* $& 287/,1( ; 89089862 &XWRXW'LPHQVLRQV Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. 76 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Notes 3 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 77 Sealed Enclosure Cooling Air Conditioners EASY SWAP ADAPTOR PLENUMS FOR AIR CONDITIONERS $LU&RQGLWLRQHU 3 Sealed Enclosure Cooling Air Conditioners $GDSWHU 3OHQXP (QFORVXUH&DELQHW 6XUIDFH INDUSTRY STANDARDS Maintains NEMA Type 12 rating when properly installed on a Type 12 enclosure. NEMA Type 12 IP 54 % APPLICATION & When existing air conditioners are damaged or have reached end-of-life, EASY SWAP Adaptor Plenums provide a quick and easy means for attaching newer Hoffman® air conditioners to the cut-out left on the enclosure. FEATURES • • • o modification of the enclosure required - designed to match the N enclosure cut-out and mounting holes of the air conditioner being replaced Plenum design allows for optimum air flow (vs. a flat plate that can block the air intake and air outtake left by the older air conditioner) Gasket included $ SPECIFICATIONS • 18 gauge steel FINISH • • 78 ainted to match the standard Hoffman air conditioner color P (light gray) O ther colors available upon request Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION EASY SWAP Adaptor Plenum Cross Reference Air Conditioner Manufacturer To Replace Hoffman Air Conditioner Series To Replace Genesis Air Conditioner Part Number To Replace M130116G014 Use This Hoffman Air Conditioner Catalog Number N170116G010 With This Adaptor Plenum Catalog Number PLM13N17 Hoffman Genesis M130126G1008 N170126G010 PLM13N17 Hoffman Genesis M130146G1400 N170146G010 PLM13N17 Hoffman Hoffman Hoffman Hoffman Genesis Genesis Genesis Genesis M170216G009 M170226G004 M170246G400 M280216G013 N170216G010 N170226G010 N170246G010 N170216G010 Not Required Not Required Not Required PLM28N17 Hoffman Genesis M280226G004 N170226G010 PLM28N17 Hoffman Genesis M280246G400 N170246G010 PLM28N17 Hoffman Genesis M280416G007 G280416G050 PLM28G28 Hoffman Genesis M280426G032 G280426G050 PLM28G28 Hoffman Genesis M280446G400 G280446G050 PLM28G28 Hoffman Genesis M280616G005 G280616G050 PLM28G28 Hoffman Genesis M280626G005 G280626G050 PLM28G28 Hoffman Genesis M280646G400 G280646G050 PLM28G28 Hoffman Genesis M330416G010 N280416G050 PLM33N28 Hoffman Genesis M330426G009 N280426G050 PLM33N28 Hoffman Genesis M330446G400 N280446G050 PLM33N28 Hoffman Genesis M360616G307 N360616G050 PLM36N36 Hoffman Genesis M360626G306 N360626G050 PLM36N36 Hoffman Genesis M360646G400 N360646G050 PLM36N36 Hoffman Genesis M520816032 G520816G050 PLM52G52 Hoffman Genesis M520826015 G520826G050 PLM52G52 Hoffman Genesis M520846G002 G520846G050 PLM52G52 Hoffman Genesis M521046G002 G521246G050 PLM52G52 Hoffman Genesis M521216017 G521216G050 PLM52G52 Hoffman Genesis M521226034 G521226G050 PLM52G52 Hoffman T-Series T290416G100 G280416G050 PLT29G28 Hoffman T-Series T290416G150 G280416G150 PLT29G28 Hoffman T-Series T290426G100 G280426G050 PLT29G28 Hoffman T-Series T290426G150 G280426G150 PLT29G28 Hoffman T-Series T290446G400 G280446G050 PLT29G28 Hoffman HC52 HC52 SERIES G57XXXXXXXX PLHC52G57 Hoffman HC52 HC52 SERIES T53XXXXXXXX PLHC52T53 Adaptor Plenum Dimensions AxBxC* (in./mm) 17.65x14.25x1.50 448x362x38 17.65x14.25x1.50 448x362x38 17.65x14.25x1.50 448x362x38 ------28.50x17.00x1.50 724x432x38 28.50x17.00x1.50 724x432x38 28.50x17.00x1.50 724x432x38 28.50x17.00x1.50 724x432x38 28.50x17.00x1.50 724x432x38 28.50x17.00x1.50 724x432x38 28.50x17.00x1.50 724x432x38 28.50x17.00x1.50 724x432x38 28.50x17.00x1.50 724x432x38 34.31x12.00x1.50 871x305x38 34.31x12.00x1.50 871x305x38 34.31x12.00x1.50 871x305x38 38.75x15.00x1.50 984x381x38 38.75x15.00x1.50 984x381x38 38.75x15.00x1.50 984x381x38 52.56x17.03x1.50 1335x433x38 52.56x17.03x1.50 1335x433x38 52.56x17.03x1.50 1335x433x38 52.56x17.03x1.50 1335x433x38 52.56x17.03x1.50 1335x433x38 52.56x17.03x1.50 1335x433x38 28.50x17.00x1.50 724x432x38 28.50x17.00x1.50 724x432x38 28.50x17.00x1.50 724x432x38 28.50x17.00x1.50 724x432x38 28.50x17.00x1.50 724x432x38 57.60x22.97x1.50 1463x583x38 52.85x23.00x1.50 1342x584x38 3 *Prior to ordering, ensure Adaptor Plenum dimensions do not exceed available space on the enclosure mounting surface. Please contact Customer Service for support in finding an appropriate cross for older models not shown above. For a list of EASY SWAP Adaptor Plenums to fit other manufacturers’ air conditioners, please visit www.hoffmanonline.com EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 79 Sealed Enclosure Cooling Air Conditioners 3 Sealed Enclosure Cooling Air Conditioners T-SERIES COMPACT OUTDOOR T15 800 BTU/Hr. 234 Watts T20 2000 BTU/Hr. 586 Watts INDUSTRY STANDARDS • UL/cUL Listed; Type 12, 3R, 4; 4X optional; File No. SA6453 UR/cUR Recognized UR/cUR Recognized on select models, reference performance data tables. CE GOST Telcordia GR-487 capable • • • APPLICATION • • • • • Industrial automation Telecommunications equipment Package handling equipment S ecurity and defense systems A nd more FEATURES • • • • • • • • • • • 80 FINISH • • tock models equipped with head pressure control for lowS ambient operation, compressor heater, coated condenser coil, malfunction switch, thermostat and heater package R134A earth-friendly refrigerant Models for 115, 230 and 460 VAC power input UL Listed to save customers time and money with agency approvals (some models UL recognized) Outdoor model operating temperature range from -40 F/-40 C to 131 F/55 C E xterior and fully recessed mounting options on many models Compact footprint to minimize real estate and maximize capacity Reliable mechanical thermostat on enclosure side of the unit Dual condenser-side air movers for performance redundancy P ainted galvanized sheet-metal cover for rugged factory and outdoor environments E asy-mount flanges for simple installation Cooling leanable, reusable aluminum mesh filter protects coils for C maximum cooling performance Mounting hardware, gaskets and user manual furnished with the unit Every unit functionally tested before shipping Standard Outdoor Air Conditioner models also include: - Telcordia GR-487 capable - Thermostat - Corrosion-resistant components - Malfunction switch - Compressor heater - Head pressure control - Enclosure heater AL 7035 light-gray, semi-textured powder-coat paint R O ther colors and textures available OPTIONS • • • • • • hermostat Malfunction Package T Special Voltage Package Outdoor Package Harsh Environment Package* Stainless Steel Package* Heater Package * PROAIR A/C may be more appropriate. Refer to PROAIR A/C Chapter. Consult the Factory for availability and catalog number. NOTES Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data T15 800 BTU/Hr. (234 Watt) Models CATALOG NUMBER Indoor Model Outdoor Model without Heat Pkg. Outdoor Model with Heat Pkg. Outdoor Model/SST/Corrosion/4X Outdoor Model/SST/Corrosion/4X/Heater COOLING PERFORMANCE Nominal: BTU/Hr. Watts At 131 F/131 F (55 C/55 C): BTU/Hr. (50/60 Hz) W (50/60 Hz) At 95 F/95 F (35 C/35 C): BTU/Hr. (50 /60 Hz) W (50/60 Hz) Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (ºF/ºC) Minimum (ºF/ºC) Airflow at 0 Static Pressure: Internal loop 50 Hz (CFM / m3/hr.) External loop 50 Hz (CFM / m3/hr.) Internal loop 60 Hz (CFM / m3/hr.) External loop 60 Hz (CFM / m3/hr.) Max. Heater W (Outdoor Models) ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (W at 50/60 Hz) Max. Nominal Current (A at 50/60 Hz) Starting Current (A) Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type CONTROLLER Description Thermostat Location Factory Thermostat Setting (ºF/ºC) SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Material Finish UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) EQUIPMENT PROTECTION T150116G120 T150116G100 T150116G150 T150116G152 T150116G151 T150126G120 T150126G100 T150126G150 T150126G104 — 800/800 235/235 800/900 235/264 819 240 920/960 270/281 948 278 R-134A 4/113 810/955 237/280 R-134A 3.8/107 131/55 -40/-40 125/131/52/55 -40/-40 25/42 48/82 30/51 53/90 150 25/42 48/82 30/51 53/90 150 100/115 50/60 +/- 10% 360/403 3.6/3.5 8.0/9.2 220/230 50/60 +/- 10% 330/345 1.5/1.5 3.3/3.1 3 cUL Listed CE GOST Others available upon request 6-ft. cord with NEMA 5-15 plug 6-ft. cord with NEMA 6-15 plug Type 12, 3R, 4 standard Type 4X Stainless steel optional Basic mechanical thermostat Enclosure behind front panel 80/27 63 dB(A) Galvanized sheet metal standard Stainless steel optional RAL 7035 light-gray, semi-textured powder-coat paint standard 15.75/400 7.5/191 6.3/160 27/12 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 81 Sealed Enclosure Cooling Air Conditioners Performance Curves for T15 Models 800 BTU/Hr. (234 Watt) 20 30 1500 Cooling Capacity (BTU/Hr.) 55 C 131 F 1250 T15-01x6-Gxxx Capacity Curves 50 Hz Ambient Air In (°C) 40 50 513 440 Enclosure Air Temperature 366 45 C 113 F 1000 35 C 95 F 293 750 25 C 77 F 220 500 147 250 73 0 68 77 86 95 104 Ambient Air In (°F) 113 122 Cooling Capacity (W) 1750 0 131 T15-01x6-Gxxx Capacity Curves 60 Hz 20 30 Ambient Air In (°C) 40 50 1750 513 Enclosure Air Temperature 440 45 C 113 F 1250 366 35 C 95 F 1000 293 25 C 77 F 750 220 500 147 250 73 0 68 82 Cooling 77 86 95 104 Ambient Air In (°F) SUBJECT TO CHANGE WITHOUT NOTICE 113 122 Cooling Capacity (W) 55 C 131 F 1500 Cooling Capacity (BTU/Hr.) 3 Sealed Enclosure Cooling Air Conditioners 0 131 EQUIPMENT PROTECTION 70RGHOV%78+U:DWW 127( 02817,1**$6.(76833/,('1276+2:1 81,76LQ>PP@ ; ),(/'&+$1*($%/( 32:(5&25'/2&$7,21 23326,7(6,'(2)81,7 $0%,(17 $,5287 ; (1&/2685( $,5,1 32:(5 &25' (;,7 $0%,(17 $,5,1 (1&/2685( $,5287 ; 3 ; ,1&+ '5$,1678% 02817,1*+2/(6; 21%$&.)$&(%(+,1')5217&29(5 02817,1*+$5':$5()25)8//<5(&(66(' 02817,1*,6%(+,1'5(029$%/()5217&29(5 &/($1$%/(5(86$%/($/80,180,1/(7),/7(5 6/,'(62876/27,1%277202))5217&29(5 ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; $&287/,1( $&287/,1( ; &XWRXW'LPHQVLRQV ([WHUQDOO\0RXQWHG &XWRXW'LPHQVLRQV ,QWHUQDOO\0RXQWHG Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 83 Sealed Enclosure Cooling Air Conditioners 3 Sealed Enclosure Cooling Air Conditioners Performance Data T20 2000 BTU/Hr. (586 Watt) Models CATALOG NUMBER Outdoor Model without Heat Pkg. Outdoor Model with Heat Pkg. Outdoor Model/SST/Corrosion/4X Outdoor Model/SST/Corrosion/4X/Heater COOLING PERFORMANCE Nominal: BTU/Hr. Watts At 131 F/131 F (55 C/55 C): BTU/Hr. (50/60 Hz) W (50/60 Hz) At 95 F/95 F (35 C/35 C): BTU/Hr. (50/60 Hz) W (50/60 Hz) Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F/°C) Minimum (°F/°C) Airflow at 0 Static Pressure: Internal loop 50 Hz (CFM / m3/hr.) External loop 50 Hz (CFM / m3/hr.) Internal loop 60 Hz (CFM / m3/hr.) External loop 60 Hz (CFM / m3/hr.) Max. Heater W (Outdoor Models) ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (W at 50/60 Hz) Max. Nominal Current (A at 50/60 Hz) Starting Current (A) Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type CONTROLLER Description Thermostat Location Factory Thermostat Setting (°F/°C) SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Material Finish UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) 84 Cooling T200216G100 T200216G150 T200216G155 T200216G157 T200226G100 T200226G150 T200226G103 T200226G158 T200246G400 — T200246G401 — 1800/2000 528/586 1800/2000 528/586 1800/2000 528/586 2000/2175 586/637 2000/2175 586/637 2000/2175 586/637 1950/2200 571/645 R-134A 6.7/190 1950/2200 571/645 R-134A 6.7/190 1950/2200 571/645 R-134A 6.7/190 131/55 -40/-40 131/55 -40/-40 131/55 -40/-40 77/131 150/255 91/155 165/280 500 77/131 150/255 91/155 165/280 500 77/131 150/255 91/155 165/280 500 115 50/60 +/- 10% 700/805 7.0/7.0 28 230 50/60 +/- 10% 805 3.5/3.5 14.4 460V 1PH 50/60 +/- 10% 874 1.9 7.2 cUR Recognized CE GOST cUL Listed CE GOST Others available upon request 6-ft. cord with NEMA 5-15 plug 6-ft. cord with NEMA 6-15 plug 6-ft. cord with wire leads Type 12, 3R, 4 standard Type 4X Stainless steel optional Basic mechanical thermostat Enclosure side on all base models 80/27 66 dB(A) Galvanized sheet metal standard Stainless steel optional RAL 7035 light-gray, semi-textured powder-coat paint standard 20/508 10/254 9.9/251 56/25 SUBJECT TO CHANGE WITHOUT NOTICE 20/508 10/254 9.9/251 56/25 24.25/615.95 10/254 9.9/251 66/30 EQUIPMENT PROTECTION Performance Curves for T20 Models 2000 BTU/Hr. (586 Watt) 20 30 T20-02x6-Gxxx Capacity Curves 50 Hz Ambient Air In (°C) 40 50 3000 Cooling Capacity (BTU/Hr.) 2500 25 C 77 F Enclosure Air Temperature 735 35 C 95 F 2000 588 1500 441 1000 294 500 147 0 68 77 86 95 104 Ambient Air In (°F) 113 122 Cooling Capacity (W) 55 C 131 F 45 C 113 F 3 0 131 T20-02x6-Gxxx Capacity Curves 60 Hz 20 30 Ambient Air In (°C) 40 50 4000 1172 Enclosure Air Temperature 45 C 113 F 3000 879 35 C 95 F 25 C 77 F 2000 586 Cooling Capacity (W) Cooling Capacity (BTU/Hr.) 55 C 131 F 293 1000 0 68 EQUIPMENT PROTECTION 77 86 95 104 Ambient Air In (°F) 113 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 122 0 131 Cooling 85 Sealed Enclosure Cooling Air Conditioners 3 Sealed Enclosure Cooling Air Conditioners 70RGHOV%78+U:DWW $0%,(17 $,5287 ; (1&/2685( $,5,1 5(029$%/( +$1*,1* 7$%6 $0%,(17 $,5,1 ; 7+(50267$7 $'-8670(17 32:(5 &25' $'-8670(17 ; (1&/2685( $,5287 02817,1*+$5':$5()25)8//<5(&(66(' 02817,1*,6%(+,1'5(029$%/()5217&29(5 &/($1$%/(5(86$%/($/80,180,1/(7),/7(5 6/,'(62876/27,1%277202))5217&29(5 ; 02817,1*+2/(6; 21%$&.)$&( %(+,1')5217&29(5 127( 02817,1**$6.(76833/,('1276+2:1 81,76LQ>PP@ ,1&+'5$,1678% ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; &XWRXW'LPHQVLRQV ([WHUQDOO\0RXQWHG ; ; ; $&287/,1( ; $&287/,1( &XWRXW'LPHQVLRQV ,QWHUQDOO\0RXQWHG Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. 86 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Notes 3 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 87 Sealed Enclosure Cooling Air Conditioners 3 Sealed Enclosure Cooling Air Conditioners T-SERIES MID-SIZE OUTDOOR T29 4000 BTU/Hr. 1173 Watts T43 6000, 8000, 10000 BTU/Hr. 1758, 2344, 2930 Watts T50 12000 BTU/Hr. 3516 Watts INDUSTRY STANDARDS T53 19000 BTU/Hr. 5567 Watts • UL/cUL Listed; Type 12, 3R, 4; 4X optional; File No. SA6453 UR/cUR Recognized UR/cUR Recognized on select models, reference performance data tables. CE GOST Telcordia GR-487 capable • • • APPLICATION • • • • • Industrial automation Telecommunications equipment Package handling equipment S ecurity and defense systems A nd more FEATURES • • • • • • • • • • • 88 FINISH • • tock models equipped with head pressure control for lowS ambient operation, compressor heater, coated condenser coil, malfunction switch, thermostat and heater package R134A or R-407C earth-friendly refrigerant Models for 115, 230 and 460 VAC power input UL Listed to save customers time and money with agency approvals (some models UL recognized) Outdoor model operating temperature range from -40 F/-40 C to 131 F/55 C E xterior and fully recessed mounting options on many models Compact footprint to minimize real estate and maximize capacity Reliable mechanical thermostat on enclosure side of the unit Dual condenser-side air movers for performance redundancy P ainted galvanized sheet-metal cover for rugged factory and outdoor environments E asy-mount flanges for simple installation Cooling leanable, reusable aluminum mesh filter protects coils for C maximum cooling performance Mounting hardware, gaskets and user manual furnished with the unit Every unit functionally tested before shipping Standard Outdoor Air Conditioner models also include: - Telcordia GR-487 capable - Thermostat - Corrosion-resistant components - Malfunction switch - Compressor heater - Head pressure control - Enclosure heater AL 7035 light-gray, semi-textured powder-coat paint R O ther colors and textures available OPTIONS • • • • • • hermostat Malfunction Package T Special Voltage Package Outdoor Package Harsh Environment Package* Stainless Steel Package* Heater Package * PROAIR Harsh Environment air conditioner may be more appropriate. Refer to PROAIR Harsh Environment air conditioner catalog section. Consult the Factory for availability and catalog number. NOTES Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data T29 4000 BTU/Hr. (1173 Watt) Models CATALOG NUMBER Outdoor Model without Heat Pkg. Outdoor Model with Heat Pkg. Outdoor Model/SST/Corrosion/4X Outdoor Model/SST/Corrosion/4X/Heater COOLING PERFORMANCE Nominal: BTU/Hr. Watts At 131 F/131 F (55 C/55 C): BTU/Hr. (50/60 Hz) W (50/60 Hz) At 95 F/95 F (35 C/35 C): BTU/Hr. (50 /60 Hz) W (50/60 Hz) Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F/°C) Minimum (°F/°C) Airflow at 0 Static Pressure: Internal loop 50 Hz (CFM / m3/hr.) External loop 50 Hz (CFM / m3/hr.) Internal loop 60 Hz (CFM / m3/hr.) External loop 60 Hz (CFM / m3/hr.) Max. Heater W (Outdoor Models) ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (W at 50/60 Hz) Max. Nominal Current (A at 50/60 Hz) Starting Current () Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type CONTROLLER Description Thermostat Location Factory Thermostat Setting (°F/°C) SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Material Finish UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) EQUIPMENT PROTECTION T290416G100 T290416G150 T290416G159 T290416G156 T290426G100 T290426G150 T290426G161 T290426G160 T290446G400 — — T290446G403 3600/4000 1055/1172 3600/4000 1055/1172 3600/4000 1055/1172 3950/4250 1157/1245 3950/4250 1157/1245 3950/4250 1157/1245 3500/3900 1025/1143 R-134A 12.5/354 3500/3900 1025/1143 R-134A 14.3/404 3500/3900 1025/1143 R-134A 14.3/404 131/55 -40/-40 131/55 -40/-40 131/55 -40/-40 172/292 195/331 205/348 235/399 1000 172/292 195/331 205/348 235/399 1000 172/292 195/331 205/348 235/399 115 50/60 +/- 10% 1163/1222 13.8/12.8 48 230 50/60 +/- 10% 1587/1564 6.9/6.8 23 460V 1PH 50/60 +/- 10% 1748 3.8 12 cUR Recognized CE GOST cUL Listed CE GOST Others available upon request 6-ft. cord with NEMA 5-20 plug 6-ft. cord with NEMA 6-15 plug 3 6-ft. cord with wire leads Type 12, 3R, 4 standard Type 4X Stainless steel optional Basic mechanical thermostat Enclosure side on all base models 80/27 67 dB(A) Galvanized sheet metal standard Stainless steel optional RAL 7035 light-gray, semi-textured powder-coat paint standard 29/737 17/432 11.3/287 107/48.6 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 29/737 17/432 11.3/287 127/58 Cooling 89 Sealed Enclosure Cooling Air Conditioners Performance Curves for T29 Models 4000 BTU/Hr. (1173 Watt) T29-04x6-Gxxx Capacity Curves 50 Hz 20 Ambient Air In (°C) 40 30 50 7000 Enclosure Air Temperature Cooling Capacity (BTU/Hr.) 55 C 131 F 1758 5000 45 C 113 F 1465 4000 35 C 95 F 1172 3000 25 C 77 F 879 Cooling Capacity (W) 2051 6000 586 2000 1000 68 77 86 95 104 Ambient Air In (°F) 113 122 293 131 T29-04x6-Gxx Capacity Curves 60 Hz 20 30 Ambient Air In (°C) 40 50 7000 2051 Enclosure Air Temperature 1758 55 C 131 F 45 C 113 F 5000 1465 35 C 95 F 4000 1172 25 C 77 F 3000 879 2000 586 1000 68 90 Cooling 77 86 95 104 Ambient Air In (°F) SUBJECT TO CHANGE WITHOUT NOTICE 113 122 Cooling Capacity (W) 6000 Cooling Capacity (BTU/Hr.) 3 Sealed Enclosure Cooling Air Conditioners 293 131 EQUIPMENT PROTECTION 70RGHOV%78+U:DWW (1&/2685( $,5,1 $0%,(17 $,5287 ; 5(029$%/( +$1*,1* 7$%6 ; &21752/6 $&&(66 3/$7( $0%,(17 $,5,1 (1&/2685( $,5287 ; 02817,1*+$5':$5()25)8//<5(&(66(' 02817,1*,6%(+,1'5(029$%/()5217&29(5 &/($1$%/(5(86$%/($/80,180,1/(7),/7(5 6/,'(62876/27,1%277202))5217&29(5 ; ; ; 02817,1*+2/(6; 21%$&.)$&( %(+,1')5217&29(5 '5$,1 678% 127( 02817,1**$6.(76833/,('1276+2:1 81,76LQ>PP@ ; ; 3 ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; &XWRXW'LPHQVLRQV ([WHUQDOO\0RXQWHG $&287/,1( $&287/,1( &XWRXW'LPHQVLRQV ,QWHUQDOO\0RXQWHG Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 91 Sealed Enclosure Cooling Air Conditioners 3 Sealed Enclosure Cooling Air Conditioners Performance Data T43 6000 BTU/Hr. (1758 Watt) Models CATALOG NUMBER Outdoor Model without Heat Pkg. Outdoor Model with Heat Pkg. Outdoor Model/SST/Corrosion/4X Outdoor Model/SST/Corrosion/4X/Heater COOLING PERFORMANCE Nominal: BTU/Hr. Watts At 131 F/131 F (55 C/55 C): BTU/Hr. (50/60 Hz) W (50/60 Hz) At 95 F/95 F (35 C/35 C): BTU/Hr. (50 /60 Hz) W (50/60 Hz) Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F/°C) Minimum (°F/°C) Airflow at 0 Static Pressure: Internal loop 50 Hz (CFM / m3/hr.) External loop 50 Hz (CFM / m3/hr.) Internal loop 60 Hz (CFM / m3/hr.) External loop 60 Hz (CFM / m3/hr.) Max. Heater W (Outdoor Models) ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (W at 50/60 Hz) Max. Nominal Current (A at 50/60 Hz) Starting Current (A) Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type International Rating CONTROLLER Description Thermostat Location Factory Thermostat Setting (°F/°C) SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Material Finish UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) 92 Cooling T430616G100 T430616G150 T430616G102 — T430626G100 T430626G150 T430626G159 — T430646G400 T430646G153 — — 6310/6680 1848/1958 6520/6770 1910/1985 6520/6770 1910/1985 6400/6680 1875/1957 6520/6774 1910/1985 6520/6774 1910/1985 5500/5900 1611/1729 R-134A 30/850 5461/5846 1600/1713 R-134A 30/850 5461/5846 1600/1713 R-134A 30/850 131/55 -40/-40 131/55 -40/-40 131/55 -40/-40 310/527 345/586 320/544 355/603 1000 310/527 345/586 320/544 355/603 1000 310/527 345/586 320/544 355/603 N/A 115 50/60 +/- 10% 1058/989 9.2/8.6 57.2 230 50/60 +/- 10% 1012/874 4.4/3.8 27 460V 1PH 50/60 +/- 10% 1104/966 2.4/2.1 14 cUR Recognized CE GOST cUL Listed CE GOST Others available upon request 6-ft. cord with NEMA 5-20 plug 6-ft. cord with NEMA 6-15 plug 6-ft. cord with wire leads Type 12, 3R, 4 standard Type 4X Stainless steel optional IP56 on the internal loop; IP34 on the external loop Basic mechanical thermostat Enclosure side on all base models 80/27 65.7 dB(A) Galvanized sheet metal standard Stainless steel optional RAL 7035 light-gray, semi-textured powder-coat paint standard 43/1092 15.75/400 10.9/279 125/57 SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Curves for T43 Models 6000 BTU/Hr. (1758 Watt) T43-06X6-G150 Capacity Curves 50 Hz 20 30 Ambient Air In (°C) 40 50 8000 2344 25 C 77 F 6000 Enclosure Air Temperature 35 C 95 F 1758 Cooling Capacity (W) Cooling Capacity (BTU/Hr.) 45 C 113 F 55 C 131 F 1172 4000 2000 68 77 86 95 104 Ambient Air In (°F) 113 122 3 586 131 T43-06X6-G150 Capacity Curves 60 Hz 20 30 8000 25 C 77 F 6000 50 2344 Enclosure Air Temperature 55 C 131 F 35 C 95 F 1758 4000 Cooling Capacity (W) Cooling Capacity (BTU/Hr.) 45 C 113 F Ambient Air In (°C) 40 1172 2000 68 EQUIPMENT PROTECTION 77 86 95 104 Ambient Air In (°F) 113 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 122 131 Cooling 93 Sealed Enclosure Cooling Air Conditioners 3 Sealed Enclosure Cooling Air Conditioners Performance Data T43 8000 BTU/Hr. (2344 Watt) Models CATALOG NUMBER Outdoor Model without Heat Pkg. Outdoor Model with Heat Pkg. Outdoor Model/SST/Corrosion/4X Outdoor Model/SST/Corrosion/4X/Heater COOLING PERFORMANCE Nominal: BTU/Hr. Watts At 131 F/131 F (55 C/55 C): BTU/Hr. (50/60 Hz) W (50/60 Hz) At 95 F/95 F (35 C/35 C): BTU/Hr. (50 /60 Hz) W (50/60 Hz) Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F/°C) Minimum (°F/°C) Airflow at 0 Static Pressure: Internal loop 50 Hz (CFM / m3/hr.) External loop 50 Hz (CFM / m3/hr.) Internal loop 60 Hz (CFM / m3/hr.) External loop 60 Hz (CFM / m3/hr.) Max. Heater W (Outdoor Models) ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (W at 50/60 Hz) Max. Nominal Current (A at 50/60 Hz) Starting Current (A) Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type International Rating CONTROLLER Description Thermostat Location Factory Thermostat Setting (°F/°C) SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Material Finish UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) 94 Cooling T430816G100 T430816G150 T430816G153 — T430826G100 T430826G150 T430826G108 — T430846G400 T430846G403 T430846G402 — 7900/8600 2310/2500 7400/8200 2160/2400 7400/8200 2160/2400 7937/8629 2326/2528 7484/8215 2193/2407 7484/8215 2193/2407 6401/7100 1875/2080 R-134A 36/1022 5940/6705 1740/1965 R-134A 36/1022 5940/6705 1740/1965 R-134A 36/1022 131/55 -40/-40 131/55 -40/-40 131/55 -40/-40 273/464 310/527 290/493 315/535 1000 273/464 310/527 290/493 315/535 1000 273/464 310/527 290/493 315/535 N/A 115 50/60 +/- 10% 1196/1288 10.4/11.2 48.3 230 50/60 +/- 10% 1196/1242 5.2/5.4 27 460V 1PH 50/60 +/- 10% 1334/1380 2.9/3.0 14 cUR Recognized CE GOST cUL Listed CE GOST Others available upon request 6-ft. cord with NEMA 5-20 plug 6-ft. cord with NEMA 6-15 plug 6-ft. cord with wire leads Type 12, 3R, 4 standard Type 4X Stainless steel optional IP56 on the internal loop; IP34 on the external loop Basic mechanical thermostat Enclosure side on all base models 80/27 65.7 dB(A) Galvanized sheet metal standard Stainless steel optional RAL 7035 light-gray, semi-textured powder-coat paint standard 43/1092 15.75/400 10.9/279 125/57 SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Curves for T43 Models 8000 BTU/Hr. (2344 Watt) T43-08X6-G150 Capacity Curves 50 Hz 20 Ambient Air In (°C) 40 30 50 12000 3516 55 C 131 F Enclosure Air Temperature 2930 45 C 113 F 8000 2344 35 C 95 F 6000 1758 Cooling Capacity (W) Cooling Capacity (BTU/Hr.) 10000 25 C 77 F 1172 4000 2000 68 77 86 95 104 Ambient Air In (°F) 113 122 3 586 131 T43-08X6-G150 Capacity Curves 60 Hz 30 55 C 131 F Ambient Air In (°C) 40 50 10000 Cooling Capacity (BTU/Hr.) 3516 Enclosure Air Temperature 2930 45 C 113 F 8000 2344 35 C 95 F 1758 6000 25 C 77 F Cooling Capacity (W) 12000 20 1172 4000 2000 68 EQUIPMENT PROTECTION 77 86 95 104 Ambient Air In (°F) 113 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 122 586 131 Cooling 95 Sealed Enclosure Cooling Air Conditioners 3 Sealed Enclosure Cooling Air Conditioners Performance Data T43 10000 BTU/Hr. (2930 Watt) Models CATALOG NUMBER Outdoor Model without Heat Pkg. Outdoor Model with Heat Pkg. Outdoor Model/SST/Corrosion/4X Outdoor Model/SST/Corrosion/4X/Heater COOLING PERFORMANCE Nominal: BTU/Hr. Watts At 131 F/131 F (55 C/55 C): BTU/Hr. (50/60 Hz) W (50/60 Hz) At 95 F/95 F (35 C/35 C): BTU/Hr. (50/60 Hz) W (50/60 Hz) Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F/°C) Minimum (°F/°C) Airflow at 0 Static Pressure: Internal loop 50 Hz (CFM / m3/hr.) External loop 50 Hz (CFM / m3/hr.) Internal loop 60 Hz (CFM / m3/hr.) External loop 60 Hz (CFM / m3/hr.) Max. Heater W (Outdoor Models) ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (W at 50/60 Hz) Max. Nominal Current (A at 50/60 Hz) Starting Current (A) Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type International Rating CONTROLLER Description Thermostat Location Factory Thermostat Setting (°F/°C) SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Material Finish UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) 96 Cooling T431016G100 T431016G150 T431016G102 T431016G153 T431026G100 T431026G150 T431026G104 T431026G152 T431046G400 — T431046G406 — 9670/10300 2831/3016 10100/10500 2957/3075 10100/10500 2957/3075 9667/10290 2832/3015 10039/10669 2941/3126 10039/10669 2941/3126 7663/8397 2245/2460 R-134A 32/907 8458/8837 2478/2589 R-134A 32/907 8458/8837 2478/2589 R-134A 32/907 131/55 -40/-40 131/55 -40/-40 131/55 -40/-40 272/462 510/866 290/493 565/960 1000 320/544 568/965 330/561 636/1081 1000 320/544 568/965 330/561 636/1081 N/A 115 50/60 +/- 10% 1828.5/2288.5 15.9/19.9 57 230 50/60 +/- 10% 2070 9 38 460V 1PH 50/60 +/- 10% 1334/1380 5 20 cUR Recognized CE GOST cUL Listed CE GOST Others available upon request 6-ft. cord with NEMA 5-30 plug 6-ft. cord with NEMA 6-15 plug 6-ft. cord with wire leads Type 12, 3R, 4 standard Type 4X Stainless steel optional IP56 on the internal loop; IP34 on the external loop Basic mechanical thermostat Enclosure side on all base models 80/27 73.3 dB(A) Galvanized sheet metal standard Stainless steel optional RAL 7035 light-gray, semi-textured powder-coat paint standard 43/1092 15.75/400 10.9/279 125/57 SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Curves for T43 Models 10000 BTU/Hr. (2930 Watt) T43-10X6-G150 Capacity Curves 50 Hz 20 Ambient Air In (°C) 40 30 50 15000 4395 Enclosure Air Temperature 3516 12000 45 C 113 F 35 C 95 F 9000 2637 25 C 77 F Cooling Capacity (W) Cooling Capacity (BTU/Hr.) 55 C 131 F 1758 6000 3000 68 77 86 95 104 Ambient Air In (°F) 113 122 3 879 131 T43-10X6-G150 Capacity Curves 60 Hz 20 30 Ambient Air In (°C) 40 50 15000 4395 45 C 113 F 12000 3516 35 C 95 F 9000 2637 25 C 77 F Cooling Capacity (W) Cooling Capacity (BTU/Hr.) 55 C 131 F Enclosure Air Temperature 1758 6000 3000 68 EQUIPMENT PROTECTION 77 86 95 104 Ambient Air In (°F) 113 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 122 879 131 Cooling 97 Sealed Enclosure Cooling Air Conditioners 3 Sealed Enclosure Cooling Air Conditioners 70RGHOV%78+5:DWW 127( 02817,1**$6.(76833/,('1276+2:1 81,76LQ>PP@ ; 32:(5&25' $/$50:,5(6 $0%,(17 $,5287 7+(50267$7 $'-8670(17 (1&/2685( $,5,1 $0%,(17 $,5,1 (1&/2685( $,5287 ; ; ; ; ; ; ; ; ; ; '5$,1 /2&$7,21 ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; $&287/,1( &XWRXW'LPHQVLRQV ([WHUQDOO\0RXQWHG $&287/,1( &XWRXW'LPHQVLRQV ,QWHUQDOO\0RXQWHG Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. 98 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data T50 12000 BTU/Hr. (3516 Watt) Models CATALOG NUMBER Outdoor Model without Heat Pkg. Outdoor Model with Heat Pkg. Outdoor Model/SST/Corrosion/4X Outdoor Model/SST/Corrosion/4X/Heater COOLING PERFORMANCE Nominal: BTU/Hr. Watts At 131 F/131 F (55 C/55 C): BTU/Hr. (50/60 Hz) W (50/60 Hz) At 95 F/95 F (35 C/35 C): BTU/Hr. (50 /60 Hz) W (50/60 Hz) Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F/°C) Minimum (°F/°C) Airflow at 0 Static Pressure: Internal loop 50 Hz (CFM / m3/hr.) External loop 50 Hz (CFM / m3/hr.) Internal loop 60 Hz (CFM / m3/hr.) External loop 60 Hz (CFM / m3/hr.) Max. Heater W (Outdoor Models) ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (W at 50/60 Hz) Max. Nominal Current (A at 50/60 Hz) Starting Current (A) Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type CONTROLLER Description Thermostat Location Factory Thermostat Setting (°F/°C) SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Material Finish UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) EQUIPMENT PROTECTION T501226G100 T501226G150 T501226G125 T501226G156 T501246G400 — T501246G401 — 11000/12000 3223/3516 11000/12000 3223/3516 10030/12000 2939/3516 10030/12000 2939/3516 9300/10050 2725/2945 R-134A 46/1300 9300/10050 2725/2945 R-134A 46/1300 131/55 -40/-40 131/55 -40/-40 300/510 520/883 368/626 625/1062 1500 300/510 520/883 368/626 625/1062 1500 220/230 50/60 +/- 10% 1804/2139 8.2/9.3 38 cUL Listed CE GOST 6-ft. cord with NEMA 6-15 plug 460V 1PH 50/60 +/- 10% 2070/2346 4.5/5.1 20 cUR Recognized CE GOST 6-ft. cord with wire leads 3 Type 12, 3R, 4 standard Type 4X Stainless steel optional Basic mechanical thermostat Enclosure side on all base models 80/27 68 dB(A) Galvanized sheet metal standard Stainless steel optional RAL 7035 light-gray, semi-textured powder-coat paint standard 50/1270 19/483 11.05/281 164/75 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 99 Sealed Enclosure Cooling Air Conditioners Performance Curves for T50 Models 12000 BTU/Hr. (3516 Watt) T50-12x6-GXXX Capacity Curves 50 Hz 20 Ambient Air In (°C) 40 30 50 18000 5274 4395 45 C 113 F 12000 3516 35 C 95 F 9000 2637 25 C 77 F 6000 1758 3000 68 77 20 86 30 95 104 Ambient Air In (°F) 113 T50-12x6-GXXX Capacity Curves 60 Hz Ambient Air In (°C) 40 122 50 18000 5274 Enclosure Air Temperature 55 C 131 F 15000 4395 45 C 113 F 12000 3516 35 C 95 F 25 C 77 F 9000 2637 1758 6000 3000 68 100 Cooling 879 131 Cooling Capacity (W) Cooling Capacity (BTU/Hr.) Enclosure Air Temperature Cooling Capacity (W) 55 C 131 F 15000 Cooling Capacity (BTU/Hr.) 3 Sealed Enclosure Cooling Air Conditioners 77 86 95 104 Ambient Air In (°F) SUBJECT TO CHANGE WITHOUT NOTICE 113 122 879 131 EQUIPMENT PROTECTION 70RGHOV%78+U:DWW 32:(5&25' (175$1&( (1&/2685( $,5,1 $0%,(17 $,5,1 ; ; 7+(50267$7 $'-8670(17 ; ; (1&/2685( $,5287 ; $0%,(17 $,5287 ; &/($1$%/(5(86$%/( $/80,180,1/(7),/7(5 %(+,1'5(029$%/(/289(56 ; 02817,1*+2/(6; '5$,1678% 3 127( 02817,1**$6.(76833/,('1276+2:1 81,76LQ>PP@ ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; $&287/,1( &XWRXW'LPHQVLRQV ([WHUQDOO\0RXQWHG $&287/,1( &XWRXW'LPHQVLRQV ,QWHUQDOO\0RXQWHG Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 101 Sealed Enclosure Cooling Air Conditioners 3 Sealed Enclosure Cooling Air Conditioners Performance Data T53 19000 BTU/Hr. (5567 Watt) Models CATALOG NUMBER Outdoor Model without Heat Pkg. Outdoor Model with Heat Pkg. Outdoor Model/SST/Corrosion/4X Outdoor Model/SST/Corrosion/4X/Heater COOLING PERFORMANCE Nominal: BTU/Hr. Watts At 131 F/131 F (55 C/55 C): BTU/Hr. (50/60 Hz) W (50/60 Hz) At 95 F/95 F (35 C/35 C): BTU/Hr. (50 /60 Hz) W (50/60 Hz) Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F/°C) Minimum (°F/°C) Airflow at 0 Static Pressure: Internal loop 50 Hz (CFM / m3/hr.) External loop 50 Hz (CFM / m3/hr.) Internal loop 60 Hz (CFM / m3/hr.) External loop 60 Hz (CFM / m3/hr.) Max. Heater W (Outdoor Models) ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (W at 50/60 Hz) Max. Nominal Current (A at 50/60 Hz) Starting Current (A) Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type CONTROLLER Description Thermostat Location Factory Thermostat Setting (°F/°C) SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Material Finish UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) 102 Cooling T531926G100 T531926G150 T531926G109 — T531946G400 — — — 16800/19000 4922/5567 16800/19000 4922/5567 16854/19081 4939/5592 16854/19081 4939/5592 15240/19815 4466/5807 410A 40/1132 15240/19815 4466/5807 410A 40/1132 131/55 -40/-40 131/55 -40/-40 449/763 1204/2046 519/882 1300/2209 3000 449/763 1204/2046 519/882 1300/2209 230 50/60 +/- 10% 3979/4669 17.3/20.3 54 cUL Listed CE GOST 460V 1PH 50/60 +/- 10% 4370/5152 9.5/11.2 28 cUR Recognized CE GOST Terminal block Type 12, 3R, 4 standard Type 4X Stainless steel optional Basic mechanical thermostat Enclosure side on all base models 80/27 76 dB(A) Galvanized sheet metal standard Stainless steel optional RAL 7035 light-gray, semi-textured powder-coat paint standard 197/90 SUBJECT TO CHANGE WITHOUT NOTICE 53.0/1346.2 21.0/533.4 13.0/330.2 237/108 EQUIPMENT PROTECTION Performance Curves for T53 Models 19000 BTU/Hr. (5567 Watt) T53-19x6-GXXX Capacity Curve 50 Hz 20 Ambient Air In (°C) 40 30 50 30000 8790 55 C 131 F Enclosure Air Temperature 7325 45 C 113 F 20000 5860 35 C 95 F 15000 4395 25 C 77 F Cooling Capacity (W) Cooling Capacity (BTU/Hr.) 25000 2930 10000 5000 68 77 86 95 104 Ambient Air In (°F) 113 122 3 1465 131 T53-19x6-GXXX Capacity Curve 60 Hz 20 30 Ambient Air In (°C) 40 50 30000 8790 Enclosure Air Temperature 55 C 131 F 45 C 113 F 7325 35 C 95 F 25 C 77 F 20000 5860 15000 4395 10000 2930 5000 68 EQUIPMENT PROTECTION 77 86 95 104 Ambient Air In (°F) 113 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 122 Cooling Capacity (W) Cooling Capacity (BTU/Hr.) 25000 1465 131 Cooling 103 Sealed Enclosure Cooling Air Conditioners 3 Sealed Enclosure Cooling Air Conditioners 70RGHOV%78+U:DWW 127( 02817,1**$6.(76833/,('1276+2:1 81,76LQ>PP@ $0%,(17 $,5,1 (1&/2685( $,5287 ; '5$,1 23(1,1* ; ; ; ; 02817,1* +$5':$5(; ; ; ; ; ; ; ; ; 32:(5 &25' ,1/(7 ; (1&/2685( $,5,1 $0%,(17 $,5287 ; $&287/,1( $&287/,1( &XWRXW'LPHQVLRQV ([WHUQDOO\0RXQWHG &XWRXW'LPHQVLRQV ,QWHUQDOO\0RXQWHG ; Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. 104 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Notes 3 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 105 Sealed Enclosure Cooling Air Conditioners 3 Sealed Enclosure Cooling Air Conditioners T-SERIES LARGE CAPACITY OUTDOOR T62 20000 BTU/Hr. 5860 Watts T70-36 36000 BTU/Hr. 10548 Watts T70-60 59000 BTU/Hr. 17287 Watts INDUSTRY STANDARDS • UL/cUL Listed; Type 12, 3R, 4; 4X optional; File No. SA6453 UR/cUR Recognized UR/cUR Recognized on select models, reference performance data tables. CE GOST Telcordia GR-487 capable • • • APPLICATION • • • • • Industrial automation Telecommunications equipment Package handling equipment S ecurity and defense systems A nd more FEATURES • • • • • • • • • • • FINISH • • tock models equipped with head pressure control for lowS ambient operation, compressor heater, coated condenser coil, malfunction switch, thermostat and heater package R-407C earth-friendly refrigerant Models for 230 and 460 VAC power input UL Listed to save customers time and money with agency approvals (some models UL recognized) Outdoor model operating temperature range from -40 F/-40 C to 131 F/55 C E xterior and fully recessed mounting options on many models Compact footprint to minimize real estate and maximize capacity Reliable mechanical thermostat on enclosure side of the unit Dual condenser-side air movers for performance redundancy P ainted galvanized sheet-metal cover for rugged factory and outdoor environments E asy-mount flanges for simple installation 106 Cooling leanable, reusable aluminum mesh filter protects coils for C maximum cooling performance Mounting hardware, gaskets and user manual furnished with the unit Every unit functionally tested before shipping Standard Outdoor Air Conditioner models also include: - Telcordia GR-487 capable - Thermostat - Corrosion-resistant components - Malfunction switch - Compressor heater - Head pressure control - Enclosure heater AL 7035 light-gray, semi-textured powder-coat paint R O ther colors and textures available OPTIONS • • • • • • hermostat Malfunction Package T Special Voltage Package Outdoor Package Harsh Environment Package* Stainless Steel Package* Heater Package * PROAIR A/C may be more appropriate. Refer to PROAIR A/C Chapter. Consult the Factory for availability and catalog number. NOTES Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data T62 20000 BTU/Hr. (5860 Watt) Models CATALOG NUMBER COOLING PERFORMANCE Nominal: BTU/Hr. Watts At 131 F/131 F (55 C/55 C): BTU/Hr. (50/60 Hz) W (50/60 Hz) At 95 F/95 F (35 C/35 C): BTU/Hr. (50 /60 Hz) W (50/60 Hz) Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F/°C) Minimum (°F/°C) Airflow at 0 Static Pressure: Internal loop 50 Hz (CFM / m3/hr.) External loop 50 Hz (CFM / m3/hr.) Internal loop 60 Hz (CFM / m3/hr.) External loop 60 Hz (CFM / m3/hr.) Max. Heater W (Outdoor Models) ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (W at 50/60 Hz) Max. Nominal Current (A at 50/60 Hz) Starting Current (A) Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type CONTROLLER Description Thermostat Location Factory Thermostat Setting (°F/°C) SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Material Finish UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) EQUIPMENT PROTECTION T622226G150 T622246G400 20500/23500 6007/6886 20500/23500 6007/6886 20860/23927 6113/7012 20860/23927 6113/7012 18258/20256 5351/5936 18258/20256 5351/5936 R-407C 42/1300 42/1300 131/55 -40/-40 131/55 -40/-40 570/968 1443/2452 673/1143 1797/3053 2000 570/968 1443/2452 673/1143 1797/3053 Up to 3000 (Optional) 230 50/60 +/- 10% 4370/5060 19/22 60 cUL Listed CE GOST Terminal block 460V 1PH 50/60 +/- 10% 7000/9200 10.5/12 30 cUR Recognized CE GOST Terminal block 3 Type 12, 3R, 4 standard Type 4X Stainless steel optional Basic mechanical thermostat Enclosure ide on all base models 80/27 71 dB(A) Galvanized sheet metal standard Stainless steel optional RAL 7035 light-gray, semi-textured powder-coat paint standard 61.77/1568.96 19.91/505.71 17.36/440.94 218/99.1 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 61.77/1568.96 19.91/505.71 17.36/440.94 258/117 Cooling 107 Sealed Enclosure Cooling Air Conditioners Performance Curves for T62 Models 20000 BTU/Hr. (5860 Watt) T62-22x6-GXXX R-407c Capacity Curves 50 Hz 20 30 Ambient Air In (°C) 40 50 40000 Cooling Capacity (BTU/Hr.) Enclosure Air Temperature 8793 45 C 113 F 35 C 95 F 20000 5862 25 C 77 F 10000 Cooling Capacity (W) 55 C 131 F 30000 2931 0 68 77 86 95 104 Ambient Air In (°F) 113 122 0 131 T62-22x6-GXXX R-407c Capacity Curves 60 Hz 20 30 Ambient Air In (°C) 40 50 40000 30000 Enclosure Air Temperature 8793 45 C 113 F 35 C 95 F 25 C 77 F 20000 5862 10000 2931 0 68 108 Cooling Cooling Capacity (W) 55 C 131 F Cooling Capacity (BTU/Hr.) 3 Sealed Enclosure Cooling Air Conditioners 77 86 95 104 Ambient Air In (°F) SUBJECT TO CHANGE WITHOUT NOTICE 113 122 0 131 EQUIPMENT PROTECTION &/($1$%/(5(86$%/( $/80,180,1/(7),/7(5 237,21$/ 70RGHOV%78+U:DWW (1&/2685( $,5,1 ; 02817,1*; ; (1&/2685( $,5287 $0%,(17 $,5287 ; $0%,(17 $,5,1 $0%,(17 $,5,1 -81&7,21 %2; /,1(92/7$*( (/(&75,&$/ (175$1&( $'-867$%/( $,5',9(57(5 237,21$/ ; 3 ; &21'(16$7( '5$,1 ; ; ; 127( 02817,1**$6.(76833/,('1276+2:1 81,76LQ>PP@ ; ; ; ; $&287/,1( ; &XWRXW'LPHQVLRQV Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 109 Sealed Enclosure Cooling Air Conditioners 3 Sealed Enclosure Cooling Air Conditioners Performance Data T70-36 36000 BTU/Hr. (10548 Watt) Models CATALOG NUMBER COOLING PERFORMANCE Nominal: BTU/Hr. Watts At 131 F/131 F (55 C/55 C): BTU/Hr. (50/60 Hz) W (50/60 Hz) At 95 F/95 F (35 C/35 C): BTU/Hr. (50 /60 Hz) W (50/60 Hz) Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F/°C) Minimum (°F/°C)Minimum (°F/°C) Airflow at 0 Static Pressure: Internal loop 50 Hz (CFM / m3/hr.) External loop 50 Hz (CFM / m3/hr.) Internal loop 60 Hz (CFM / m3/hr.) External loop 60 Hz (CFM / m3/hr.) Max. Heater W (Outdoor Models) ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (W at 50/60 Hz) Max. Nominal Current (A at 50/60 Hz) Starting Current (A) Agency Approvals T703626G150 39000/43000 11430/12602 38613/42930 11316/12570 31364/36130 9192/10579 R-407C 110/3118 131/55 -40/-40 1085/1843 2176/3697 1171/1989 2347/3987 2000 Standard (5000 Optional) 230 50/60 +/- 10% 8280 36 104 Power Input Description ENCLOSURE PROTECTION UL Type International Rating CONTROLLER Description Thermostat Location Factory Thermostat Setting (°F/°C) SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Material Finish UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) 110 Cooling T703646G400 cUL Listed CE GOST Others available upon request Terminal block 460 60 +/- 10% 8280 18 52 Type 12, 3R, 4 standard Type 4X Stainless steel optional UL/cUL Listed Basic mechanical thermostat Enclosure side on all base models 80/27 66 dB(A) Galvanized sheet metal standard Stainless steel optional RAL 7035 light-gray, semi-textured powder-coat paint standard 69.8/1772 22.8/578 20.94/532 260/118 SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Curves for T70 Models 36000 BTU/Hr. (10548 Watt) T70-36X6-GXXX R-407c Capacity Curves 50 Hz 20 Ambient Air In (°C) 40 30 50 60000 Cooling Capacity (BTU/Hr.) 50000 Enclosure Air Temperature 14655 45 C 113 F 40000 Cooling Capacity (W) 55 C 131 F 11724 35 C 95 F 30000 8793 25 C 77 F 20000 5862 10000 2931 131 68 77 86 95 104 Ambient Air In (°F) 113 122 3 T70-36X6-GXXX R-407c Capacity Curves 60 Hz 20 30 Ambient Air In (°C) 40 50 60000 Cooling Capacity (BTU/Hr.) 50000 Enclosure Air Temperature 14655 45 C 113 F 35 C 95 F 40000 11724 25 C 77 F 30000 8793 Cooling Capacity (W) 55 C 131 F 5862 20000 10000 68 EQUIPMENT PROTECTION 77 86 95 104 Ambient Air In (°F) 113 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 122 2931 131 Cooling 111 Sealed Enclosure Cooling Air Conditioners 3 Sealed Enclosure Cooling Air Conditioners 70RGHOV%78+U:DWW 02817,1*; (1&/2685( $,5,1 $0%,(17 $,5287 $0%,(17 $,5,1 /2:92/7$*( (/(&75,&$/ (175$1&( &/($1$%/(5(86$%/( $/80,180$,5),/7(5 -81&7,21 %2; (1&/2685( $,5287 /,1( 92/7$*( (/(&75,&$/ (175$1&( $0%,(17 $,5,1 ; ; ; ; &21'(16$7( '5$,1 ; ; 127( 02817,1**$6.(76833/,('1276+2:1 81,76LQ>PP@ ; ; ; ; ; ; $&287/,1( &XWRXW'LPHQVLRQV Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. 112 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data T70-60 59000 BTU/Hr. (17287 Watt) Models CATALOG NUMBER COOLING PERFORMANCE Nominal: BTU/Hr. Watts At 122 F/122 F (50 C/50 C): BTU/Hr. (50/60 Hz) W (50/60 Hz) At 95 F/95 F (35 C/35 C): BTU/Hr. (50 /60 Hz) W (50/60 Hz) Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F/°C) Minimum (°F/°C) Airflow at 0 Static Pressure: Internal loop 50 Hz (CFM / m3/hr.) External loop 50 Hz (CFM / m3/hr.) Internal loop 60 Hz (CFM / m3/hr.) External loop 60 Hz (CFM / m3/hr.) Max. Heater W (Outdoor Models) ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (W at 50/60 Hz) Max. Nominal Current (A at 50/60 Hz) Starting Current (A) Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type International Rating Description CONTROLLER Thermostat Location Factory Thermostat Setting (°F/°C) SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Material Finish UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) EQUIPMENT PROTECTION T706026G150 T706046G400 51900/60000 15210/17584 51900/60000 15210/17584 47122/54500 13810/15972 R-407C 150/4252 122/50 -40/-40 1510/2565 2716/4614 1629/2767 2931/4979 200/230 50/60 +/- 10% 7000/9200 35/40 144 cUL Listed CE GOST Others available upon request Terminal block 420/460 50/60 +/- 10% 6426/7038 15.3 144 3 Type 12, 3R, 4 standard Type 4X Stainless steel optional IP56 on the internal loop; IP34 on the external loop Basic mechanical thermostat Enclosure side on all base models 80/27 66 dB(A) Galvanized sheet metal standard Stainless steel optional RAL 7035 light-gray, semi-textured powder-coat paint standard 69.77/1772 35.86/911 22.94/583 419/190.5 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 113 Sealed Enclosure Cooling Air Conditioners Performance Curves for T70 Models 59000 BTU/Hr. (17287 Watt) T70-60X6-GXXX R-407c Capacity Curves 50 Hz 20 65000 30 55 C 131 F Ambient Air In (°C) 40 50 Enclosure Air Temperature 16120 55000 35 C 95 F 13189 45000 25 C 77 F Cooling Capacity (W) Cooling Capacity (BTU/Hr.) 45 C 113 F 10258 35000 25000 68 77 86 95 104 Ambient Air In (°F) 113 122 7327 131 T70-60X6-GXXX R-407c Capacity Curves 60 Hz 20 30 Ambient Air In (°C) 40 50 85000 Enclosure Air Temperature 21982 45 C 113 F 65000 19051 35 C 95 F 55000 16120 25 C 77 F 45000 13189 10258 35000 25000 68 114 Cooling Cooling Capacity (W) 55 C 131 F 75000 Cooling Capacity (BTU/Hr.) 3 Sealed Enclosure Cooling Air Conditioners 77 86 95 104 Ambient Air In (°F) SUBJECT TO CHANGE WITHOUT NOTICE 113 122 7327 131 EQUIPMENT PROTECTION 70RGHOV%78+U:DWW &/($1$%/(5(86$%/( $/80,180$,5),/7(5 (1&/2685( $,5,1 $0%,(17 $,5287 $0%,(17 $,5,1 /2: 92/7$*( (/(&75,&$/ (175$1&( /,1( 92/7$*( (/(&75,&$/ (175$1&( ; $'-867$%/( $,5 ',9(57(5 &21'(16$7( '5$,1 ; ; 3 ; (1&/2685( $,5287 ; -81&7,21 %2; $0%,(17 $,5,1 127( 02817,1**$6.(76833/,('1276+2:1 81,76LQ>PP@ ; ; ; ; ; 02817,1* ; $&287/,1( &XWRXW'LPHQVLRQV Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 115 Sealed Enclosure Cooling Air Conditioners 3 Sealed Enclosure Cooling Air Conditioners GENESIS™ TOP-MOUNT INDOOR HB16 8000 BTU/Hr. 2051 Watt MHB11 2200-4000 BTU/Hr. 645-1172 Watt INDUSTRY STANDARDS • UL/cUL Listed; Type 12; File No. SA6453 UR/cUR Recognized • Maintains U/cUL Type 12 rating when properly installed on a UL/cUL Type 12 enclosure. UR/cUR Recognized on select models, reference performance data tables. CE GOST APPLICATION • • • • Industrial automation Package handling equipment S ecurity and defense systems Ideal for use where there is little or no clearance around the enclosure FEATURES • • • • • • • obust reciprocating compressor R R134a and R407c earth-friendly refrigerant Models for 115, 230 and 460 single-phase VAC power input UL Listed or Recognized to save customers time and money with agency approvals Operating temperature range from 50 F/10 C to 125 F/52 C Attractive industrial design with minimal use of visible fasteners Reliable mechanical thermostat located behind the filter of the unit 116 Cooling • • • ow-carbon mild-steel sheet-metal cover for rugged factory L environments Cleanable, reusable aluminum mesh filter protects coils for maximum cooling performance Mounting hardware, gaskets and user manual furnished with the unit Every unit functionally tested before shipping Standard Indoor Air Conditioner models also include: - Electro-Mechanical Thermostat - Surge Suppressor - Condensate Management System On MHB11 models FINISH • • AL 7042 gray, semi-gloss powder-coat paint standard R O ther colors and textures available OPTIONS • • hermostat Malfunction Package T Special Voltage Package * Consult the factory for availability and catalog number NOTES Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data MHB11 Models 2200 BTU/Hr. (645 Watt) CATALOG NUMBER COOLING PERFORMANCE Nominal: BTU/Hr. Watts Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F/°C) Minimum (°F/°C) Airflow at 0 Static Pressure: Internal loop 50 Hz (CFM / m3/hr.) External loop 50 Hz (CFM / m3/hr.) Internal loop 60 Hz (CFM / m3/hr.) External loop 60 Hz (CFM / m3/hr.) ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (W at 50/60 Hz) Max. Nominal Current (A at 50/60 Hz) Starting Current (A) Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type CONTROLLER Description Thermostat Location Factory Thermostat Setting (°F/°C) SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Material Finish UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) EQUIPMENT PROTECTION MHB110216G306 MHB110226G306 MHB110246G400 2200/2200 645/645 R-134A 11/312 2200/2200 645/645 R-134A 11/312 2200/2200 645/645 R-134A 11/312 125/52 50/10 125/52 50/10 125/52 50/10 158/268 222/377 177/301 252/428 170/289 218/370 192/326 245/416 170/289 218/370 192/326 245/416 115 50/60 +/- 10% 1127/1035 9.8/9.0 28 220/230 50/60 +/- 10% 1210/1058 5.5/4.6 14.4 440/460V 1PH 50/60 +/- 10% 1320/1150 3.0/2.5 7.4 cUR Recognized CE GOST cUL Listed CE GOST Others available upon request 6-ft. cord with NEMA 5-15 plug 6-ft. cord with NEMA 6-15 plug 6-ft. cord with wire leads Type 12 standard 3 Basic mechanical thermostat Behind filter 80/27 62 dB(A) Mild steel sheet metal standard Stainless steel optional RAL 7042 gray, semi-gloss powder-coat paint standard 10.25/260 17/432 21.08/535 90/41 10.25/260 17/432 21.08/535 90/41 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 10.25/260 17/432 21.08/535 110/50 Cooling 117 Sealed Enclosure Cooling Air Conditioners 3 Sealed Enclosure Cooling Air Conditioners Performance Data MHB11 Models 4000 BTU/Hr. (1172 Watt) CATALOG NUMBER COOLING PERFORMANCE Nominal: BTU/Hr. Watts Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F/°C) Minimum (°F/°C) Airflow at 0 Static Pressure: Internal loop 50 Hz (CFM / m3/hr.) External loop 50 Hz (CFM / m3/hr.) Internal loop 60 Hz (CFM / m3/hr.) External loop 60 Hz (CFM / m3/hr.) ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (W at 50/60 Hz) Max. Nominal Current (A at 50/60 Hz) Starting Current (A) Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type CONTROLLER Description Thermostat Location Factory Thermostat Setting (°F/°C) SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Material Finish UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) 118 Cooling MHB110416G307 MHB110426G306 MHB110446G400 3300/4000 967/1172 R-134A 13/369 3300/4000 967/1172 R-134A 13/369 3300/4000 967/1172 R-134A 13/369 125/52 50/10 125/52 50/10 125/52 50/10 158/268 222/377 177/301 252/428 170/289 218/370 192/326 245/416 170/289 218/370 192/326 245/416 110/115 50/60 +/- 10% 1617/1564 14.7/13.6 48 220/230 50/60 +/- 10% 1760/1725 8.0/7.5 23 440/460V 1PH 50/60 +/- 10% 1936/1886 4.4/4.1 12 cUR Recognized CE GOST cUL Listed CE GOST Others available upon request 6-ft. cord with NEMA 5-20 plug 6-ft. cord with NEMA 6-15 plug 6-ft. cord with wire leads Type 12 standard Basic mechanical thermostat Behind filter 80/27 62 dB(A) Mild steel sheet metal standard Stainless steel optional RAL 7042 gray, semi-gloss powder-coat paint standard 10.25/260 17/432 21.08/535 108/49 SUBJECT TO CHANGE WITHOUT NOTICE 10.25/260 17/432 21.08/535 108/49 10.25/260 17/432 21.08/535 128/58 EQUIPMENT PROTECTION 0+%0RGHOV%78+U:DWW 127( 02817,1**$6.(76833/,('1276+2:1 81,76LQ>PP@ &87287',0(16,216)2567$1'$5'81,7621/< ; &/($1$%/(5(86$%/( $/80,180,1/(7),/7(5 %(+,1'*5,//( $0%,(17 $,5287 $0%,(17 $,5,1 $/7(51$7( 29(5)/2:'5$,1 (,7+(56,'( (1&/2685( $,5,1 ; ; 67$1'$5'&21'(16$7( '5$,1/2&$7,21 5() ; 5() ; ; 5() ; 5() 81&; ; 3 &22/ $,5287 ; ; $&287/,1( &XWRXW'LPHQVLRQV Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 119 Sealed Enclosure Cooling Air Conditioners 3 Sealed Enclosure Cooling Air Conditioners Performance Data HB16 Models 8000 BTU/Hr. (2051 Watt) MODEL NUMBER Indoor Model COOLING PERFORMANCE Nominal: BTU/Hr. Watts At 125 F/125 F (52 C/52 C): BTU/Hr. (50/60 Hz) Watts (50/60 Hz) At 95 F/95 F (35 C/35 C): BTU/Hr. (50/60 Hz) W (50/60 Hz) Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F/°C) Minimum (°F/°C) ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (W at 50/60 Hz) Max. Nominal Current (A at 50/60 Hz) Starting Current (A) Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type CONTROLLER Description Thermostat Location Factory Thermostat Setting (°F/°C) UNIT CONSTRUCTION Material Finish UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) 120 Cooling HB160816G040 HB160826G040 HB160846G040 7000/8000 2051/2344 7000/8000 2051/2344 7000/8000 2051/2344 6975/8137 2044/2385 7075/8133 2073/2384 7075/8133 2073/2384 6959/8236 2039/2414 R-407C 24/680 6958/7774 2039/2278 R-407C 24/680 6958/7774 2039/2278 R-407C 24/680 125/52 50/10 125/52 50/10 125/52 50/10 115 50/60 +/- 10% 1822/2223 18.7/20.4 67 230 50/60 +/- 10% 1785/2105 8.5/9.3 29 cUL Listed CE GOST 6-ft. cord with NEMA 5-20 plug 460 50/60 +/- 10% 2162 4.3/4.7 15 6-ft. cord with NEMA 5-20 plug 6-ft. cord with NEMA L8-20 plug Type 12 Standard Basic Mechanical Thermostat Enclosure Side on All Base Models 80/27 80/27 80/27 Galvanized Sheet Metal Standard (Optional: Stainless Steel) RAL 7042 gray, semi-gloss powder-coat paint standard Other colors and textures available 15.25/387.35 17.00/431.80 25.19/639.76 145.00/69.78 SUBJECT TO CHANGE WITHOUT NOTICE 15.25/387.35 17.00/431.80 25.19/639.76 145.00/69.78 15.25/387.35 17.00/431.80 25.19/639.76 170.00/77.00 EQUIPMENT PROTECTION +%0RGHOV%78V+U:DWWV >@ >@ &/($1$%/( 5(86$%/( $/80,180 ,1/(7),/7(5 >@ >@ >@ $0%,(17 $,5287 >@ $0%,(17 $,5,1 >@ >@ &22/$,5 287 >@ 6(59,&( &25' >@ >@ )URQW9LHZ (1&/2685( $,55(7851 5HDU9LHZ 6LGH9LHZ >@ >@ >@ ,''5$,1+26( >@ >@ >@ >@ >@ >@ >@ 81&% 3 >@ >@ >@ %RWWRP9LHZ 5() ; 5() 5() 5() $,5&21',7,21(5287/,1( &XWRXW Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 121 Sealed Enclosure Cooling Air Conditioners 3 Sealed Enclosure Cooling Air Conditioners PROAIR HARSH ENVIRONMENT CR23 1600 BTU/Hr. 469 Watts CR29 2200 and 4000 BTU/Hr. 645 and 1172 Watts INDUSTRY STANDARDS • UL/cUL Listed; Type 12, 3R, 4; 4X optional; File No. SA6453 UR/cUR Recognized UR/cUR Recognized on select models, reference performance data tables. CE GOST • • • • APPLICATION • • • • • • Industrial automation Package handling equipment Food and beverage Wastewater treatment S ecurity and defense systems A nd more FEATURES • • • • • • • • • • CR43 6000 & 8000 BTU/Hr. 1758 and 2344 Watts leanable reusable aluminum mesh filter protects coils for C maximum cooling performance Mounting hardware, gaskets and user manual furnished with the unit Every unit functionally tested before shipping High-performance fans and blowers designed for densely packed enclosures Standard Indoor Air Conditioner models also include: - Electro-Mechanical Thermostat - Surge Suppressor FINISH • • • AL 7035 light-gray, semi-textured powder-coat paint standard R Stainless steel Type 304 or 316 finishes available on Type 4X models O ther colors and textures available OPTIONS • T hermostat Malfunction Package obust reciprocating compressor R • Special Voltage Package E asy maintenance: hinged front cover allows quick access to all • Outdoor Package* components; condenser coil can be cleaned while unit is still • Harsh Environment Package* mounted to the cabinet • Stainless Steel Package* R134a or R407c earth-friendly refrigerant • Heater Package* Models for 115, 230 and 460 single phase VAC power input * T-Series may be more appropriate. Refer to T-Series A/C UL Listed or Recognized to save customers time and money with section. Consult the factory for availability and catalog agency approvals number. Operating temperature range from -40 F/-40 C to 131 F/55 C (with optional low-ambient package) NOTES Attractive industrial design with minimal use of visible fasteners Visit www.HoffmanOnline.com to download 2D and 3D CAD Reliable mechanical thermostat located behind the filter of the drawings into the overall design of your electronic system. unit Low-carbon mild-steel sheet-metal cover for rugged factory and outdoor environments E asy-mount flanges for simple installation 122 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data CR23 Models 1600 BTU/Hr. (469 Watt) CATALOG NUMBER Indoor Model Indoor Level 2 Controller Outdoor Type 3R Outdoor/SST/Corrosion Type 3R Outdoor/SST/Level 2 Type 3R Indoor/Outdoor/SST/Corrosion Type 4X COOLING PERFORMANCE Nominal: BTU/Hr. Watts Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F/°C) Minimum (°F/°C) (Low Ambient Pkg) Airflow at 0 Static Pressure: Internal loop 50 Hz (CFM / m3/hr.) External loop 50 Hz (CFM / m3/hr.) Internal loop 60 Hz (CFM / m3/hr.) External loop 60 Hz (CFM / m3/hr.) ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (W at 50/60 Hz) Max. Nominal Current (A at 50/60 Hz) Starting Current (A) Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type CONTROLLER Description Thermostat Location Factory Thermostat Setting (°F/°C) SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Material Finish UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) EQUIPMENT PROTECTION CR230216G002 CR230216G016 CR230216G013 CR230216G007 CR230216G017 CR230216G015 CR230226G002 — CR230226G030 CR230226G009 CR230226G016 CR230226G014 CR230246G400 — — — — CR230226G037 1400/1600 410/469 R-134A 10/284 1400/1600 410/469 R-134A 10/284 1400/1600 410/469 R-134A 10/284 131/55 -40/-40 131/55 -40/-40 131/55 -40/-40 117/199 86/146 130/221 95/161 117/199 86/146 130/221 95/161 117/199 86/146 130/221 95/161 115 50/60 +/- 10% 471.5/517.5 4.1/4.5 18 230 50/60 +/- 10% 506 2.2 8.5 460V 1PH 50/60 +/- 10% 552 1.2 5 cUR Recognized CE GOST 6-ft. cord with wire leads cUL Listed CE GOST 6-ft. cord with NEMA 5-15 plug 6-ft. cord with NEMA 6-15 plug 3 Type 12, 3R standard Type 4, 4X Stainless steel optional Basic mechanical thermostat Behind cover 80/27 62 dB(A) Mild steel sheet metal standard Stainless steel optional RAL 7035 light-gray, semi-textured powder-coat paint standard 23/584 10/254 8.75/222 57/26 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 23/584 10/254 8.75/222 67/30 Cooling 123 Sealed Enclosure Cooling Air Conditioners 3 Sealed Enclosure Cooling Air Conditioners &50RGHOV%78+U:DWW 127( 02817,1**$6.(76833/,('1276+2:1 81,76LQ>PP@ &/($1$%/(5(86$%/( $/80,180,1/(7),/7(5 ; ; (1&/2685( $,5,1 $0%,(17 $,5,1 81& ; &22/ $,5287 ; $0%,(17 $,5287 67$1'$5' &21'(16$7( '5$,1 /2&$7,21 ; ; ; ; ; ; ; $&287/,1( &XWRXW'LPHQVLRQV Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. 124 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION &50RGHOV%78+U:DWW:LWK7\SH;+RRG 127( 02817,1**$6.(76833/,('1276+2:1 81,76LQ>PP@ &/($1$%/(5(86$%/( $/80,180,1/(7),/7(5 ; ; (1&/2685( $,5,1 81& ; &22/ $,5287 $0%,(17 $,5,1 ; $0%,(17 $,5287 67$1'$5' &21'(16$7( '5$,1 /2&$7,21 ; 3 ; ; ; ; ; ; $&287/,1( &XWRXW'LPHQVLRQV Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 125 Sealed Enclosure Cooling Air Conditioners 3 Sealed Enclosure Cooling Air Conditioners Performance Data CR29 Models 2200/4000 BTU/Hr. (645/1172 Watt) CATALOG NUMBER Indoor Model Indoor Level 2 Controller Outdoor Type 3R Outdoor/SST/Corrosion Type 3R Outdoor/SST/Level 2 Type 3R Indoor/Outdoor/SST/Corrosion Type 4X COOLING PERFORMANCE Nominal: BTU/Hr. Watts Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F/°C) Minimum (°F/°C) (Low Ambient Pkg) Airflow at 0 Static Pressure: Internal loop 50 Hz (CFM / m3/hr.) External loop 50 Hz (CFM / m3/hr.) Internal loop 60 Hz (CFM / m3/hr.) External loop 60 Hz (CFM / m3/hr.) ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (W at 50/60 Hz) Max. Nominal Current (A at 50/60 Hz) Starting Current (A) Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type CONTROLLER Description Thermostat Location Factory Thermostat Setting (°F/°C) SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Material Finish UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) 126 Cooling CR290216G002 CR290216G030 CR290216G035 CR290216G013 — CR290216G036 CR290226G002 CR290226G030 CR290226G020 CR290226G010 CR290226G031 CR290226G037 CR290246G400 CR290226G041 CR290226G046 CR290246G401 CR290226G058 CR290226G045 CR290416G002 CR290416G047 CR290416G045 CR290416G030 CR290416G052 CR290416G068 CR290426G002 CR290426G027 CR290426G022 CR290426G017 — CR290426G054 CR290446G400 — CR290426G067 — CR290426G101 CR290426G061 2000/2200 586/645 R-134A 11/312 2500/2700 732/791 R-134A 11/312 2500/2700 732/791 R-134A 11/312 3500/4000 1025/1172 R-134A 11/312 3500/4000 1025/1172 R-134A 12/341 3500/4000 1026/1172 R-134A 12/341 131/55 -40/-40 131/55 -40/-40 131/55 -40/-40 131/55 -40/-40 131/55 -40/-40 131/55 -40/-40 141/239 235/399 157/266 261/443 141/239 235/399 157/266 261/443 141/239 235/399 157/266 261/443 141/239 235/399 157/266 261/443 141/239 235/399 157/266 261/443 141/239 235/399 157/266 261/443 115 50/60 +/- 10% 851/517.5 230 50/60 +/- 10% 1058/877 460V 1PH 50/60 +/- 10% 1150/996 115 50/60 +/- 10% 1116/1253 230 50/60 +/- 10% 1541/1518 460V 1PH 50/60 +/- 10% 1702/1656 7.4 4.6/3.9 2.5/2.1 12.7/12.1 6.7/6.6 3.7/3.6 7.4 cUR Recognized CE GOST 6-ft. cord with wire leads 44.5 28 14.4 cUL Listed CE GOST 6-ft. cord 6-ft. cord with NEMA with NEMA 5-15 plug 6-15 plug 23 cUL Listed CE GOST 6-ft. cord 6-ft. cord with NEMA with NEMA 5-20 plug 6-15 plug 12 cUR Recognized CE GOST 6-ft. cord with wire leads Type 12, 3R standard Type 4, 4X Stainless steel optional Type 12, 3R standard 4, 4X Stainless steel optional Basic mechanical thermostat Behind cover 80/27 Basic mechanical thermostat Behind cover 80/27 68 dB(A) 68 dB(A) Mild steel sheet metal standard Stainless steel optional RAL 7035 light-gray, semi-textured powder-coat paint standard Mild steel sheet metal standard Stainless steel optional RAL 7035 light-gray, semi-textured powder-coat paint standard 29.5/749 15.75/400 8.63/219 98/44 29.5/749 15.75/400 8.63/219 118/54 98/44 108/49 SUBJECT TO CHANGE WITHOUT NOTICE 118/54 128/58 EQUIPMENT PROTECTION &50RGHOV%78+U:DWW 127( 02817,1**$6.(76833/,('1276+2:1 81,76LQ>PP@ &/($1$%/(5(86$%/( $/80,180,1/(7),/7(5 ; (1&/2685( $,5,1 ; ; $0%,(17 $,5,1 &22/ $,5287 $0%,(17 $,5287 81&; ; 67$1'$5' &21'(16$7( '5$,1/2&$7,21 3 ; ; ; ; ; $&287/,1( &XWRXW'LPHQVLRQV Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 127 Sealed Enclosure Cooling Air Conditioners 3 Sealed Enclosure Cooling Air Conditioners &50RGHOV%78+U:DWW:LWK7\SH;+RRG 127( 02817,1**$6.(76833/,('1276+2:1 81,76LQ>PP@ &/($1$%/(5(86$%/( $/80,180,1/(7),/7(5 ; (1&/2685( $,5,1 ; ; $0%,(17 $,5,1 &22/ $,5287 $0%,(17 $,5287 ; 81&; ; 67$1'$5' &21'(16$7( '5$,1/2&$7,21 ; ; ; ; $&287/,1( &XWRXW'LPHQVLRQV Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. 128 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data CR43 Models 6000/8000 BTU/Hr. (1758/2344 Watt) CATALOG NUMBER Indoor Model Indoor Level 2 Controller Outdoor Type 3R Outdoor/SST/Corrosion Type 3R Outdoor/SST/Level 2 Type 3R Indoor/Outdoor/SST/Corrosion Type 4X COOLING PERFORMANCE Nominal: BTU/Hr. Watts Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F/°C) Minimum (°F/°C) (Low Ambient Pkg.) Airflow at 0 Static Pressure: Internal loop 50 Hz (CFM / m3/hr.) External loop 50 Hz (CFM / m3/hr.) Internal loop 60 Hz (CFM / m3/hr.) External loop 60 Hz (CFM / m3/hr.) ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (W at 50/60 Hz) Max. Nominal Current (A at 50/60 Hz) Starting Current (A) Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type CONTROLLER Description Thermostat Location Factory Thermostat Setting (°F/°C) SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Material Finish UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) EQUIPMENT PROTECTION CR430616G002 CR430616G016 CR430616G013 CR430616G004 — CR430616G031 CR430626G002 CR430626G018 CR430626G014 — CR430626G020 CR430626G034 CR430646G004 CR430626G030 — — — CR430626G074 CR430816G002 CR430816G021 CR430816G038 CR430816G010 CR430816G023 CR430816G036 CR430826G002 CR430826G026 CR430826G007 CR430826G037 CR430826G024 CR430826G038 CR430826G089 — — — — CR430846G401 5500/6000 1611/1758 R-134A 19/538 5500/6000 1611/1758 R-134A 19/538 5500/6000 1611/1758 R-134A 19/538 7100/8000 2080/2344 R-134A 19/538 7100/8000 2080/2344 R-134A 19/538 7100/8000 2080/2344 R-134A 19/538 131/55 -40/-40 131/55 -40/-40 131/55 -40/-40 131/55 -40/-40 131/55 -40/-40 131/55 -40/-40 320/543 480/815 368/625 544/924 226/384 470/798 255/433 540/917 226/384 470/798 255/433 540/917 320/543 480/815 368/625 544/924 226/384 470/798 255/433 540/917 226/384 470/798 255/433 540/917 115 230 50/60 50/60 +/- 10% +/- 10% 1460 1403/1518 12.7 6.1/6.6 48.3 27 cUL Listed CE GOST Others available upon request 6-ft. cord 6-ft. cord with NEMA with NEMA 5-20 plug 6-15 plug 460V 1PH 50/60 +/- 10% 1564/1656 3.4/3.6 14 cUR Recognized CE GOST 6-ft. cord with wire leads 115 230 50/60 50/60 +/- 10% +/- 10% 1460 1403/1518 12.7 6.1/6.6 48.3 27 cUL Listed CE GOST Others available upon request 6-ft. cord 6-ft. cord with NEMA with NEMA 5-20 plug 6-15 plug 460V 1PH 50/60 +/- 10% 1564/1656 3.4/3.6 14 cUR Recognized CE GOST 6-ft. cord with wire leads Type 12, 3R standard Type 4, 4X Stainless steel optional Type 12, 3R standard 4, 4X Stainless steel optional Basic mechanical thermostat Enclosure side on all base models 80/27 Basic mechanical thermostat Enclosure side on all base models 80/27 71 dB(A) 71 dB(A) Galvanized sheet metal standard Stainless steel optional RAL 7035 light-gray, semi-textured powder-coat paint standard Galvanized sheet metal standard Stainless steel optional RAL 7035 light-gray, semi-textured powder-coat paint standard 43.31/1100 15.75/400 10.25/260 125/57 43.31/1100 15.75/400 10.25/260 125/57 125/57 155/70 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 125/57 155/70 Cooling 129 3 Sealed Enclosure Cooling Air Conditioners 3 Sealed Enclosure Cooling Air Conditioners &50RGHOV%78+U:DWW ; ; ; ; (1&/2685( $,5,1 ; ; &22/ $,5287 $0%,(17 $,5,1 81&; $0%,(17 $,5287 67$1'$5'&21'(16$7( '5$,1/2&$7,21 ; ; 127( 02817,1**$6.(76833/,('1276+2:1 81,76LQ>PP@ ; ; ; ; ; $&287/,1( &XWRXW'LPHQVLRQV Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. 130 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION &50RGHOV%78+U:DWW:LWK7\SH;+RRG ; ; ; ; (1&/2685( $,5,1 ; ; &22/ $,5287 $0%,(17 $,5,1 81&; 3 $0%,(17 $,5287 67$1'$5'&21'(16$7( '5$,1/2&$7,21 ; ; ; ; ; 127( 02817,1**$6.(76833/,('1276+2:1 81,76LQ>PP@ ; ; $&287/,1( &XWRXW'LPHQVLRQV Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 131 Sealed Enclosure Cooling Air Conditioners 3 Sealed Enclosure Cooling Air Conditioners WATER-COOLED INDOOR APPLICATION • • • • • • • Industrial automation P ackage handling equipment Food and beverage Wastewater treatment S ecurity and defense systems Pulp and paper A nd more FEATURES • • • • • • • • • • • • • • obust reciprocating compressor R R134a earth-friendly refrigerant Models for 115 VAC, 230 VAC and 460 V 1-phase power input UL Listed or Recognized to save customers time and money with agency approvals Operating temperature range from 50 F/10 C to 125 F/52 C Attractive industrial design with minimal use of visible fasteners Reliable mechanical thermostat located behind the front panel of the unit Low-carbon mild-steel sheet-metal cover for rugged factory and outdoor environments E asy-mount flanges for simple installation Mounting hardware, gaskets and user manual furnished with the unit Every unit functionally tested before shipping Heat is removed from the system by means of the water cooling the refrigerant; no external air movers or condenser coils to get clogged Maximum water usage of 2 GPM at 90 F water intake temperature Standard Indoor Air Conditioner models also include: - Electro-Mechanical Thermostat - Surge Suppressor FINISH 33WC 4000 BTU/Hr. 1172 Watt • • • OPTIONS INDUSTRY STANDARDS UL/cUL Listed; Type 12; File No. SA6453 UR/cUR Recognized UR/cUR Recognized on select models, reference performance data tables. CE GOST 132 Cooling AL 7042 gray, semi-gloss powder-coat paint standard R Stainless steel Type 304 or 316 finishes available on Type 4X models O ther colors and textures available • • • • • hermostat Malfunction Package T Special Voltage Package Active Condensate Evaporator Package Harsh Environment Package* Stainless Steel Package* * Consult the factory for availability and catalog number. NOTES Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data 33WC Models 4000 BTU/Hr. (1172 Watt) CATALOG NUMBER COOLING PERFORMANCE Nominal: BTU/Hr. Watts Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F/°C) Minimum (°F/°C) Airflow at 0 Static Pressure: Internal loop 50 Hz (CFM / m3/hr.) External loop 50 Hz Internal loop 60 Hz (CFM / m3/hr.) External loop 60 Hz ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (W at 50/60 Hz) Max. Nominal Current (A at 50/60 Hz) Starting Current (A) Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type CONTROLLER Description Thermostat Location Factory Thermostat Setting (°F/°C) SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Material Finish UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) 330416GW010 330426GW014 330426GW012 3800/4000 1113/1172 R-134A 7/198 3800/4000 1113/1172 R-134A 7/198 3800/4000 1113/1172 R-134A 7/198 125/52 50/10 125/52 50/10 125/52 50/10 135/229 Waterflow: 0.5 GPM @ 90 F 145/246 Waterflow: 0.5 GPM @ 90 F 100/170 Waterflow: 0.5 GPM @ 90 F 110/187 Waterflow: 0.5 GPM @ 90 F 100/170 Waterflow: 0.5 GPM @ 90 F 110/187 Waterflow: 0.5 GPM @ 90 F 115 50/60 +/- 10% 690/667 6.0/5.8 28 220/230 50/60 +/- 10% 726/736 3.3/3.2 14.4 460V 1PH 50/60 +/- 10% 828/782 1.8/1.7 7.4 cUR Recognized CE GOST 6-ft. cord with wire leads cUL Listed CE GOST 6-ft. cord with NEMA 5-15 plug 6-ft. cord with NEMA 6-15 plug Type 12 standard Basic mechanical thermostat Behind front cover 80/27 3 61 dB(A) Mild steel sheet metal standard Stainless steel optional RAL 7042 gray, semi-gloss powder-coat paint standard 34.13/867 12.38/314 8.75/222 86/39 38.63/981.2 12.38/314 8.75/222 106/48 33WC EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 133 Sealed Enclosure Cooling Air Conditioners 3 Sealed Enclosure Cooling Air Conditioners 33WC Models 4000 BTU/Hr. (1172 Watt) 89045090 Cutout Dimensions Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. 134 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Notes 3 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 135 Sealed Enclosure Cooling Air Conditioners 3 Sealed Enclosure Cooling Air Conditioners WATER-COOLED INDOOR/OUTDOOR APPLICATION • • • • • • • Industrial automation P ackage handling equipment Food and beverage Wastewater treatment S ecurity and defense systems Pulp and paper A nd more FEATURES • • • • • • • • • • • • • • obust reciprocating compressor R R134a earth-friendly refrigerant Models for 115 and 230 VAC power input UL Listed or Recognized to save customers time and money with agency approvals Operating temperature range from 50 F/10 C to 125 F/52 C Attractive industrial design with minimal use of visible fasteners Reliable mechanical thermostat located behind the front panel of the unit Low-carbon mild-steel sheet-metal cover for rugged factory and outdoor environments E asy-mount flanges for simple installation Mounting hardware, gaskets and user manual furnished with the unit Every unit functionally tested before shipping Heat is removed from the system by means of the water cooling the refrigerant; no external air movers or condenser coils to get clogged Maximum water usage of 2 GPM at 90 F water intake temperature Standard Indoor Air Conditioner models also include: - Electro-Mechanical Thermostat - Surge Suppressor FINISH • • CR43WC 8000 BTU/Hr. 2345 Watt • OPTIONS INDUSTRY STANDARDS UL/cUL Listed; Type 4; 4X optional; File No. SA6453 UR/cUR Recognized UR/cUR Recognized on select models, reference performance data tables. CE GOST 136 Cooling AL 7035 light-gray, semi-textured powder-coat paint standard R Stainless steel Type 304 or 316 finishes available on Type 4X models O ther colors and textures available • • • • • hermostat Malfunction Package T Special Voltage Package Active Condensate Evaporator Package Harsh Environment Package* Stainless Steel Package* * Consult the factory for availability and catalog number. NOTES Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data CR43WC Models 8000 BTU/Hr. (2345 Watt) CATALOG NUMBER COOLING PERFORMANCE Nominal: BTU/Hr. Watts Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F/°C) Minimum (°F/°C) Airflow at 0 Static Pressure: Internal loop 50 Hz (CFM / m3/hr.) External loop 50 Hz Internal loop 60 Hz (CFM / m3/hr.) External loop 60 Hz ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (W at 50 / 60 Hz) Max. Nominal Current (A at 50 / 60 Hz) Starting Current (A) Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type CONTROLLER Description Thermostat Location Factory Thermostat Setting (°F/°C) SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Material Finish UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) CR430816GW010 CR430826GWXXX 8500 2490 R-134A 12/341 8500 2490 R-134A 12/341 131/55 50/10 131/55 50/10 135/229 Waterflow: 1.5 GPM @ 90F 145/246 Waterflow: 1.5 GPM @ 90F 100/170 Waterflow: 1.5 GPM @ 90F 110/187 Waterflow: 1.5 GPM @ 90F 115 50/60 +/- 10% 1518/1495 13.2/13 48.3 230 50/60 +/- 10% 1518/1495 6.6/6.5 27 6-ft. cord with NEMA 5-15 plug cUL Listed CE GOST 6-ft. cord with NEMA 6-15 plug Type 4 standard Type 4X Stainless steel optional Basic mechanical thermostat Behind front cover 80/27 3 61 dB(A) Mild steel sheet metal standard Stainless steel optional RAL 7035 light-gray, semi-textured powder-coat paint standard 43.31/1100 15.75/400 10.25/260.4 86/39 CR43WC EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 137 Sealed Enclosure Cooling Air Conditioners 3 Sealed Enclosure Cooling Air Conditioners CR43WC Models 8000 BTU/Hr. (2345 Watt) 89045091 Cutout Dimensions Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. 138 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Notes 3 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 139 Sealed Enclosure Cooling Air Conditioners 3 Sealed Enclosure Cooling Air Conditioners WATER-COOLED RACK-MOUNT LB11WC 4000 BTU/Hr. 1172 Watt INDUSTRY STANDARDS • UL/cUL Listed; Type 12; File No. SA6453 UR/cUR Recognized • • UR/cUR Recognized on select models, reference performance data tables. CE GOST • • APPLICATION • • • • • • • Industrial automation Package handling equipment Food and beverage Wastewater treatment S ecurity and defense systems Pulp and paper A nd more FEATURES • • • • • • • • FINISH • • • Cooling AL 7042 gray, semi-gloss powder-coat paint standard R Stainless steel Type 304 or 316 finishes available on Type 4X models O ther colors and textures available OPTIONS obust reciprocating compressor R R134a earth-friendly refrigerant Models for 115 and 230 VAC power input UL Listed or Recognized to save customers time and money with agency approvals Operating temperature range from 50 F/10 C to 125 F/52 C Reliable mechanical thermostat located behind the front panel of the unit Low-carbon mild-steel sheet-metal cover for rugged factory and outdoor environments E asy-mount flanges for simple installation 140 ounting hardware, gaskets and user manual furnished with the M unit Every unit functionally tested before shipping Heat is removed from the system by means of the water cooling the refrigerant; no external air movers or condenser coils to get clogged Maximum water usage of 2 GPM at 90 F water intake temperature Standard Indoor Air Conditioner models also include: - Electro-Mechanical Thermostat - Surge Suppressor • • • • • hermostat Malfunction Package T Special Voltage Package Active Condensate Evaporator Package Harsh Environment Package* Stainless Steel Package* * Consult the factory for availability and catalog number. NOTES Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data LB11WC Models 4000 BTU/Hr. (1172 Watt) CATALOG NUMBER COOLING PERFORMANCE Nominal: BTU/Hr. Watts Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F/°C) Minimum (°F/°C) Airflow at 0 Static Pressure: Internal loop 50 Hz (CFM / m3/hr.) External loop 50 Hz Internal loop 60 Hz (CFM / m3/hr.) External loop 60 Hz ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (W at 50/60 Hz) Max. Nominal Current (A at 50/60 Hz) Starting Current (A) Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type CONTROLLER Description Thermostat Location Factory Thermostat Setting (°F/°C) SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Material Finish UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) EQUIPMENT PROTECTION LB110416GW008 LB110426GW010 3900/4000 1142/1172 R-134A 12/340 3900/4000 1142/1172 R-134A 12/340 125/52 50/10 125/52 50/10 135/229 Waterflow: 1.0 GPM @ 90 F 145/246 Waterflow: 1.0 GPM @ 90 F 100/170 Waterflow: 1.0 GPM @ 90 F 110/187 Waterflow: 1.0 GPM @ 90 F 115 50/60 +/- 10% 885.5/828 7.7/7.2 28 Not listed 230 50/60 +/- 10% 897/792 3.9/3.6 14.4 cUL Listed CE GOST 6-ft. cord with NEMA 6-15 plug 6-ft. cord with NEMA 5-15 plug Type 12 standard Basic mechanical thermostat Behind front cover 80/27 3 61 dB(A) Mild steel sheet metal standard Stainless steel optional RAL 7042 gray, semi-gloss powder-coat paint standard 10.47/266 19/483 19.63/499 110/50 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 141 Sealed Enclosure Cooling Air Conditioners 3 Sealed Enclosure Cooling Air Conditioners LB11WC Models 4000 BTU/Hr. (1172 Watt) 89045092 Cutout Dimensions Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. 142 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Notes 3 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 143 Sealed Enclosure Cooling Air Conditioners 3 Sealed Enclosure Cooling Heat Exchangers CLIMAGUARD™ AIR-TO-AIR INDOOR HEAT EXCHANGERS XR20 Models 4 W/°F (7 W/°C) XR29-08 Models 8 W/°F (14 W/°C) XR29-18 Models 18 W/°F (32 W/°C) XR47-24 Models 24 W/°F (43 W/°C) INDUSTRY STANDARDS Type 12 on XR20 and XR29-08 models Type 3R on XR29-18 and larger models when surface mounted vertically on an enclosure CE GOST APPLICATION Industrial automation Package handling equipment S ecurity and defense systems A nd more FEATURES • • • • • • • • • • • • Cooling • • • AL 7035 light-gray, semi-textured powder-coat paint standard R Stainless steel Type 304 or 316 finishes available on Type 4X models O ther colors and textures available OPTIONS • • • • Special Voltage Package Outdoor Package* Harsh Environment Package* Stainless Steel Package* * CLIMAGUARD™ may be more appropriate. Refer to CLIMAGUARD Air-to-Air Outdoor chapter. Consult the factory for availability and catalog number. NOTES nique counterflow aluminum core for high-efficiency and highU performance heat transfer, except for the XR20 and XR29-08 which use a modified heat pipe core Models for 115 and 230 VAC power input UL Listed or Recognized to save customers time and money with agency approvals Operating temperature range from -20 F/-29 C to 140 F/60 C Streamlined aesthetics with no visible mounting rails; Slim design allows for mounting to narrow or shallow enclosures Reliable top-quality bearing fans and impellers make these units run quietly and with increased reliability Low-carbon mild-steel sheet-metal cover for rugged factory environments E asy-mount flanges for simple installation Mounting hardware, gaskets and user manual furnished with the unit Every unit functionally tested before shipping F ilterless design for low maintenance and easy cleaning Four fasteners allow simple removal of front cover for easy access 144 XR60-84 Models 84 W/°F (151 W/°C) FINISH UL/cUL Listed; Type 12, 3R; File No. SA7402 UR/cUR Recognized • • • • XR47-35 XR60-55 Models Models 35 W/°F (63 W/°C) 55 W/°F (99 W/°C) Visit www.hoffmanonline.com to download 2D and 3D CAD drawings into the overall design of your electronic system SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data XR20 Models 4 W/°F (7 W/°C) CATALOG NUMBER COOLING PERFORMANCE Nominal: W per °F W per °C Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F/°C) Minimum (°F/°C) Airflow at 0 Static Pressure: Internal loop 50 Hz (CFM / m3/hr.) External loop 50 Hz (CFM / m3/hr.) Internal loop 60 Hz (CFM / m3/hr.) External loop 60 Hz (CFM / m3/hr.) ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (W at 50/60 Hz) Max. Nominal Current (A at 50/60 Hz) Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Material XR200416012 XR200426012 4 7 R-134A 4/113 4 7 R-134A 4/113 140/60 -20/-29 140/60 -20/-29 71/121 75/127 74/126 78/132 71/121 75/127 74/126 78/132 115 50/60 +/- 10% 69 0.6 230 50/60 +/- 10% 69 0.3 6-ft. cord with NEMA 5-15 plug cUL Listed CE GOST 6-ft. cord with NEMA 6-15 plug Type 12 standard 56 dBA 3 Mild steel sheet metal standard Stainless steel optional RAL 7035 light-gray, semi-textured powder-coat paint standard Finish UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) 20/508 7.5/190.5 3/76.2 12/5.4 20/508 7.5/190.5 3/76.2 12/5.4 Mounting Options Note: Internal mounting requires inverting the heat exchanger as shown. External Top-Mount EQUIPMENT PROTECTION Internal Top-Mount External Vertical-Mount PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Internal Vertical-Mount Cooling 145 Sealed Enclosure Cooling Heat Exchangers 3 Sealed Enclosure Cooling Heat Exchangers ;50RGHOV:r):r& $0%,(17 $,5287 ; ; (1&/2685( $,5,1 6(('(7$,/$ 6((127( ; $0%,(17 $,5,1 ; (1&/2685( $,5287 ; 81& ; '(7$,/$ ; ; ; ; ; ; +(287/,1( 127( 02817,1**$6.(76833/,('1276+2:1 81,76LQ>PP@ 6(59,&(&25'7(50,1$7(':,7+$335235,$7(3/8* 1(0$3)25981,76 1(0$3)25981,76 '(7$&+$%/($,5)/2:3/(1800$<%(86(':+(1 02817,1*7+(+($7(;&+$1*(5,16,'(252876,'( 2)7+((1&/2685( &XWRXW'LPHQVLRQV Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. 146 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data XR29 Models 8 W/°F (14 W/°C) CATALOG NUMBER COOLING PERFORMANCE Nominal: W per °F W per °C Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F/°C) Minimum (°F/°C) Airflow at 0 Static Pressure: Internal loop 50 Hz (CFM / m3/hr.) External loop 50 Hz (CFM / m3/hr.) Internal loop 60 Hz (CFM / m3/hr.) External loop 60 Hz (CFM / m3/hr.) ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (W at 50/60 Hz) Max. Nominal Current (A at 50/60 Hz) Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Material Finish UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) EQUIPMENT PROTECTION XR290816012 XR290826012 8 14 R-134A 5.5/156 8 14 R-134A 5.5/156 140/60 -20/-29 140/60 -20/-29 71/121 75/127 74/126 78/132 71/121 75/127 74/126 78/132 115 50/60 +/- 10% 69 0.6 230 50/60 +/- 10% 69 0.3 6-ft. cord with NEMA 5-15 plug cUL Listed CE GOST 6-ft. cord with NEMA 6-15 plug Type 12 standard 56 dBA 3 Mild steel sheet metal standard Stainless steel optional RAL 7035 light-gray, semi-textured powder-coat paint standard 29.5/749.3 10/254 3.09/78.5 21/9.5 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 29.5/749.3 10/254 3.09/78.5 21/9.5 Cooling 147 Sealed Enclosure Cooling Heat Exchangers 3 Sealed Enclosure Cooling Heat Exchangers ;50RGHOV:r):r& (1&/2685( $,5,1 ; ; 6(('(7$,/$ 6((127( $0%,(17 $,5287 ; $0%,(17 $,5,1 ; (1&/2685( $,5287 ; 81& ; ; ; ; ; ; '(7$,/$ ; r; 127( 02817,1**$6.(76833/,('1276+2:1 81,76LQ>PP@ 6(59,&(&25'7(50,1$7(':,7+$335235,$7(3/8* 1(0$S)25981,76 1(0$3)25981,76 '(7$&+$%/($,5)/2:3/(1800$<%(86(':+(1 02817,1*7+(+($7(;&+$1*(5,16,'(252876,'( 2)7+((1&/2685( +(287/,1( &XWRXW'LPHQVLRQV Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. 148 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data XR29 Models 18 W/°F (32 W/°C) CATALOG NUMBER COOLING PERFORMANCE Nominal: W per °F W per °C Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F/°C) Minimum (°F/°C) Airflow at 0 Static Pressure: Internal loop 50 Hz (CFM / m3/hr.) External loop 50 Hz (CFM / m3/hr.) Internal loop 60 Hz (CFM / m3/hr.) External loop 60 Hz (CFM / m3/hr.) ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (W at 50/60 Hz) Max. Nominal Current (A at 50/60 Hz) Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Material Finish UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) EQUIPMENT PROTECTION XR291816012 XR291826012 18 32 N/A N/A 18 32 N/A N/A 140/60 -20/-29 140/60 -20/-29 126/214 120/204 140/237 133/226 126/214 120/204 140/237 133/226 115 50/60 +/- 10% 207 1.8 230 50/60 +/- 10% 207 0.9 6-ft. cord with NEMA 5-15 plug cUL Listed CE GOST 6-ft. cord with NEMA 6-15 plug Type 12 standard Type 3R, 4, 4X optional 64 dBA 3 Mild steel sheet metal standard Stainless steel optional RAL 7035 light-gray, semi-textured powder-coat paint standard 29.66/753.3 10.24/260.1 5.92/150.4 32/15 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 29.66/753.3 10.24/260.1 5.92/150.4 32/15 Cooling 149 Sealed Enclosure Cooling Heat Exchangers 3 Sealed Enclosure Cooling Heat Exchangers ;50RGHOV:r):r& ; 02817,1* +$5':$5( (1&/2685( $,5,1 ; ,(&& 32:(5 ,1/(7 ; $0%,(17 $,5287 ; (1&/2685( $,5287 $0%,(17 $,5,1 127( 02817,1**$6.(76833/,('1276+2:1 81,76LQ>PP@ ; ; ; ; ; ; ; ; ; ; ; +(287/,1( &XWRXW'LPHQVLRQV Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. 150 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data XR47 Models 24 W/°F (43 W/°C) CATALOG NUMBER COOLING PERFORMANCE Nominal: W per °F W per °C Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F/°C) Minimum (°F/°C) Airflow at 0 Static Pressure: Internal loop 50 Hz (CFM / m3/hr.) External loop 50 Hz (CFM / m3/hr.) Internal loop 60 Hz (CFM / m3/hr.) External loop 60 Hz (CFM / m3/hr.) ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (W at 50/60 Hz) Max. Nominal Current (A at 50/60 Hz) Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Material Finish UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) EQUIPMENT PROTECTION XR472416012 XR472426012 24 43 N/A N/A 24 43 N/A N/A 140/60 -20/-29 140/60 -20/-29 140/238 118/200 156/265 131/222 140/238 118/200 156/265 131/222 115 50/60 +/- 10% 207 1.8 230 50/60 +/- 10% 207 0.9 6-ft. cord with NEMA 5-15 plug cUL Listed CE GOST 6-ft. cord with NEMA 6-15 plug Type 12 standard Type 3R, 4, 4X optional 68 dBA 3 Mild steel sheet metal standard Stainless steel optional RAL 7035 light-gray, semi-textured powder-coat paint standard 47.16/1197.9 10.24/260.1 5.92/150.4 51/23 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 47.16/1197.9 10.24/260.1 5.92/150.4 51/23 Cooling 151 Sealed Enclosure Cooling Heat Exchangers 3 Sealed Enclosure Cooling Heat Exchangers ;50RGHOV:r):r& ; 02817,1* +$5':$5( (1&/2685( $,5,1 ; ; ; ,(&& 32:(5 ,1/(7 $0%,(17 $,5287 ; (1&/2685( $,5287 ; $0%,(17 $,5,1 ; ; ; ; ; ; ; +(287/,1( &XWRXW'LPHQVLRQV Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. 152 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data XR47 Models 35 W/°F (63 W/°C) CATALOG NUMBER COOLING PERFORMANCE Nominal: W per °F W per °C Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F/°C) Minimum (°F/°C) Airflow at 0 Static Pressure: Internal loop 50 Hz (CFM / m3/hr.) External loop 50 Hz (CFM / m3/hr.) Internal loop 60 Hz (CFM / m3/hr.) External loop 60 Hz (CFM / m3/hr.) ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (W at 50/60 Hz) Max. Nominal Current (A at 50/60 Hz) Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Material Finish UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) EQUIPMENT PROTECTION XR473516012 XR473526012 35 63 N/A N/A 35 63 N/A N/A 140/60 -20/-29 140/60 -20/-29 120/204 131/222 133/226 146/248 120/204 131/222 133/226 146/248 115 50/60 +/- 10% 207 1.8 230 50/60 +/- 10% 207 0.9 6-ft. cord with NEMA 5-15 plug cUL Listed CE GOST 6-ft. cord with NEMA 6-15 plug Type 12 standard Type 3R, 4, 4X optional 68 dBA 3 Mild steel sheet metal standard Stainless steel optional RAL 7035 light-gray, semi-textured powder-coat paint standard 47.16/1197.8 15.24/387.1 5.92/150.4 59/27 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 47.16/1197.8 15.24/387.1 5.92/150.4 59/27 Cooling 153 Sealed Enclosure Cooling Heat Exchangers 3 Sealed Enclosure Cooling Heat Exchangers ;50RGHOV:r):r& ; 02817,1* +$5':$5( (1&/2685( $,5,1 $0%,(17 $,5287 ; ; ; ; ,(& 32:(5 ,1/(7 ; (1&/2685( $,5287 $0%,(17 $,5,1 ; ; 127( 02817,1**$6.(76833/,('1276+2:1 81,76LQ>PP@ 0(7(5/21*6(59,&(&25'7(50,1$7(' :,7+$335235,$7(3/8* 1(0$3)25981,76 1(0$3)25981,76 ; ; ; ; ; ; ; ; +(287/,1( ; ; &XWRXW'LPHQVLRQV Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. 154 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data XR60 Models 55 W/°F (99 W/°C) CATALOG NUMBER COOLING PERFORMANCE Nominal: W per °F W per °C Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F/°C) Minimum (°F/°C) Airflow at 0 Static Pressure: Internal loop 50 Hz (CFM / m3/hr.) External loop 50 Hz (CFM / m3/hr.) Internal loop 60 Hz (CFM / m3/hr.) External loop 60 Hz (CFM / m3/hr.) ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (W at 50/60 Hz) Max. Nominal Current (A at 50/60 Hz) Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Material Finish UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) EQUIPMENT PROTECTION XR605516012 XR605526012 55 99 N/A N/A 55 99 N/A N/A 140/60 -20/-29 140/60 -20/-29 398/676 429/729 442/751 477/810 398/676 429/729 442/751 477/810 115 50/60 +/- 10% 759 6.6 230 50/60 +/- 10% 759 3.3 6-ft. cord with NEMA 5-15 plug cUL Listed CE GOST 6-ft. cord with NEMA 6-15 plug Type 12 standard Type 3R, 4, 4X optional 73 dBA 3 Mild steel sheet metal standard Stainless steel optional RAL 7035 light-gray, semi-textured powder-coat paint standard 59.66/1515.3 15.24/387.1 5.92/150.4 86/39 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 59.66/1515.3 15.24/387.1 5.92/150.4 86/39 Cooling 155 Sealed Enclosure Cooling Heat Exchangers 3 Sealed Enclosure Cooling Heat Exchangers ;50RGHOV:r):r& ; 02817,1* +$5':$5( (1&/2685( $,5,1 ; ; ; ,(& 32:(5 ,1/(7 ; $0%,(17 $,5287 ; ; $0%,(17 $,5,1 (1&/2685( $,5287 ; ; ; 127( 02817,1**$6.(76833/,(' 1276+2:1 81,76LQ>PP@ 0(7(5/21*6(59,&(&25' 6833/,(':,7+$335235,$7(3/8* 1(0$3)25981,76 1(0$3)25981,76 ; ; ; ; ; ; +(287/,1( &XWRXW'LPHQVLRQV Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. 156 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data XR60 Models 84 W/°F (151 W/°C) CATALOG NUMBER COOLING PERFORMANCE Nominal: W per °F W per °C Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F/°C) Minimum (°F/°C) Airflow at 0 Static Pressure: Internal loop 50 Hz (CFM / m3/hr.) External loop 50 Hz (CFM / m3/hr.) Internal loop 60 Hz (CFM / m3/hr.) External loop 60 Hz (CFM / m3/hr.) ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (W at 50/60 Hz) Max. Nominal Current (A at 50/60 Hz) Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Material Finish UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) EQUIPMENT PROTECTION XR608416012 XR608426012 84 151 N/A N/A 84 151 N/A N/A 140/60 -20/-29 140/60 -20/-29 497/844 434/737 552/938 482/819 497/844 434/737 552/938 482/819 115 50/60 +/- 10% 759 6.6 230 50/60 +/- 10% 759 3.3 6-ft. cord with NEMA 5-15 plug cUL Listed CE GOST 6-ft. cord with NEMA 6-15 plug Type 12 standard Type 3R, 4, 4X optional 73 dBA 3 Mild steel sheet metal standard Stainless steel optional RAL 7035 light-gray, semi-textured powder-coat paint standard 59.66/1515.3 15.24/387.1 9.92/252 106/48 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 59.66/1515.3 15.24/387.1 9.92/252 106/48 Cooling 157 Sealed Enclosure Cooling Heat Exchangers 3 Sealed Enclosure Cooling Heat Exchangers ;50RGHOV:r):r& ; 02817,1* +$5':$5( (1&/2685( $,5,1 ; ; ; ; ,(& 32:(5 ,1/(7 $0%,(17 $,5287 (1&/2685( $,5287 ; ; $0%,(17 $,5,1 ; ; 127( 02817,1**$6.(76833/,('1276+2:1 81,76LQ>PP@ 0(7(5/21*6(59,&(&25'6833/,(' :,7+$335235,$7(3/8* 1(0$3)25981,76 1(0$3)25981,76 ; ; ; ; ; ; +(287/,1( &XWRXW'LPHQVLRQV Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. 158 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Notes 3 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 159 Sealed Enclosure Cooling Heat Exchangers 3 Sealed Enclosure Cooling Heat Exchangers CLIMAGUARD™ AIR-TO-AIR OUTDOOR TX23 Models 14 W/°F (25 W/°C) TX33 Models 28 W/°F (50 W/°C) INDUSTRY STANDARDS UL/cUL Listed; Type 12, 3R, 4; 4X optional; File No. SA7402 UR/cUR Recognized UR/cUR Recognized on select models, reference performance data tables. CE GOST Telcordia GR-487 capable APPLICATION • • • • • Telecom shelters Outdoor cabinets Equipment buildings Instrument enclosures A nd more FEATURES • • • • • • • Cooling • • • • • TX52 Models 83 W/°F (150 W/°C) asy-mount flanges for simple installation E Mounting hardware, gaskets and user manual furnished with the unit Every unit functionally tested before shipping Filterless design for low maintenance and easy cleaning Engineered for temperature extremes, corrosive environments and wind driven rain FINISH • • • AL 7035 light-gray, semi-textured powder-coat paint standard R Stainless steel Type 304 or 316 finishes available on Type 4X models O ther colors and textures available OPTIONS nique counterflow aluminum core for high efficiency and high U performance heat transfer Models for 24 VDC, 48 VDC, 115 VAC and 230 VAC power supplies UL Listed or Recognized to save customers time and money with agency approvals Operating temperature range from -40 F/-40 C to 149 F/65 C Variable speed blowers standard on DC powered units for quiet running Surface or recessed mount capable Low-carbon mild-steel sheet-metal cover for rugged factory environments 160 TX38 Models 56 W/°F (100 W/°C) • • • • • • Thermostat Package Special Voltage Package Outdoor Package Harsh Environment Package* Stainless Steel Package* Heater Package* * Consult the factory for availability and catalog number. NOTES Visit www.HoffmanCoolingTech.com to download 2D and 3D CAD drawings into the overall design of your electronic system SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data TX23 Models 14 W/°F (25 W/°C) CATALOG NUMBER COOLING PERFORMANCE Nominal: W per °F W per °C Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range Maximum (°F/°C) Minimum (°F/°C) Airflow at 0 Static Pressure: Internal loop 50 Hz (CFM / m3/hr.) External loop 50 Hz (CFM / m3/hr.) Internal loop 60 Hz (CFM / m3/hr.) External loop 60 Hz (CFM / m3/hr.) ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (W at 50/60 Hz) Max. Nominal Current (A at 50/60 Hz) Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Material Finish UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) EQUIPMENT PROTECTION TX231416100 TX231426100 TX231424100 TX231448100 14 25 N/A N/A 14 25 N/A N/A 14 25 N/A N/A 14 25 N/A N/A 149/65 -40/-40 149/65 -40/-40 149/65 -40/-40 149/65 -40/-40 69/117 58/98 84/142 69/117 69/117 58/98 84/142 69/117 N/A N/A 175/268 158/297 N/A N/A 175/268 158/297 115 VAC 50/60 +/- 10% 69 0.6 230 VAC 50/60 +/- 10% 23 0.1 24 VDC 50/60 +/- 10% 82 3.4 48 VDC 50/60 +/- 10% 87 1.8 cUL Listed CE GOST 6-ft. cord with NEMA 5-15 plug 6-ft. cord with NEMA 6-15 plug cUL Listed CE GOST Terminal block Terminal block Type 12, 3R, 4 standard Type 4X optional Type 12, 3R, 4 standard Type 4X optional 56 dBA 56 dBA Mild steel sheet metal standard Stainless steel optional RAL 7035 light-gray, semi-textured powder-coat paint standard Mild steel sheet metal standard Stainless steel optional RAL 7035 light-gray, semi-textured powder-coat paint standard 23/584.2 12/304.8 7.1/180.3 30/13.6 23/584.2 12/304.8 7.1/180.3 30/13.6 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 23/584.2 12/304.8 7.1/180.3 30/13.6 3 23/584.2 12/304.8 7.1/180.3 30/13.6 Cooling 161 Sealed Enclosure Cooling Heat Exchangers 3 Sealed Enclosure Cooling Heat Exchangers 7;'&0RGHOV:r)r& 127( 02817,1**$6.(76833/,('1276+2:1 81,76LQ>PP@ $0%,(17 $,5287 ; 5(029$%/( +$1*,1* 7$%6; $0%,(17 $,5,1 ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; +(287/,1( &87287',0(16,216 (;7(51$/02817 Cooling ; ; 162 ,03(//(532:(5 $1'$/$50 ,17(5)$&( ; (1&/2685( $,5287 02817,1*+$5':$5()25,17(51$//02817(' 02817,1*,6%(+,1'5(029$%/(&29(5 ; $&+($7(532:(5 ; (1&/2685( $,5,1 ; &21752//(5/('6 02817,1*; 21%$&.)$&( %(+,1')5217&29(5 ; +(287/,1( &87287',0(16,216 ,17(51$/02817 SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION 7;$&0RGHOV:r):r& 127( 02817,1**$6.(76833/,('1276+2:1 81,76LQ>PP@ (1&/2685( $,5,1 $0%,(17 $,5287 ; 5(029$%/( +$1*,1* 7$%6; (1&/2685( $,5287 ; ; $0%,(17 $,5,1 32:(5&25' (175$1&( ; 02817,1*; 21%$&.)$&( %(+,1')5217&29(5 ; ; 3 02817,1*+$5':$5()25 ,17(51$//<02817(' 02817,1*,6%(+,1' 5(029$%/()5217&29(5 ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; +( 287/,1( ; +(287/,1( &87287',0(16,216 (;7(51$/02817 EQUIPMENT PROTECTION ; &87287',0(16,216 ,17(51$/02817 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 163 Sealed Enclosure Cooling Heat Exchangers 3 Sealed Enclosure Cooling Heat Exchangers Performance Data TX33 Models 28 W/°F (50 W/°C) CATALOG NUMBER COOLING PERFORMANCE Nominal: W per °F W per °C Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F/°C) Minimum (°F/°C) Airflow at 0 Static Pressure: Internal loop 50 Hz (CFM / m3/hr.) External loop 50 Hz (CFM / m3/hr.) Internal loop 60 Hz (CFM / m3/hr.) External loop 60 Hz (CFM / m3/hr.) ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (W at 50/60 Hz) Max. Nominal Current (A at 50/60 Hz) Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Material Finish UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) 164 Cooling TX332816100 TX332826100 TX332824100 TX332848100 28 50 N/A N/A 28 50 N/A N/A 28 50 N/A N/A 28 50 N/A N/A 149/65 -40/-40 149/65 -40/-40 149/65 -40/-40 149/65 -40/-40 212/360 238/404 228/387 263/447 212/360 238/404 228/387 263/447 N/A N/A 228/387 166/282 N/A N/A 228/387 166/282 115 VAC 50/60 +/- 10% 161 1.4 230 VAC 50/60 +/- 10% 92 0.4 24 VDC 50/60 +/- 10% 82 3.4 48 VDC 50/60 +/- 10% 87 1.8 cUL Listed CE GOST 6-ft. cord with NEMA 5-15 plug 6-ft. cord with NEMA 6-15 plug cUL Listed CE GOST Terminal block Terminal block Type 12, 3R, 4 standard Type 4X optional Type 12, 3R, 4 standard Type 4X optional 56 dBA 56 dBA Mild steel sheet metal standard Stainless steel optional RAL 7035 light-gray, semi-textured powder-coat paint standard Mild steel sheet metal standard Stainless steel optional RAL 7035 light-gray, semi-textured powder-coat paint standard 33/838.2 15.7/398.8 8.1/205.7 45/20.4 33/838.2 15.7/398.8 8.1/205.7 45/20.4 33/838.2 15.7/398.8 8.1/205.7 45/20.4 SUBJECT TO CHANGE WITHOUT NOTICE 33/838.2 15.7/398.8 8.1/205.7 45/20.4 EQUIPMENT PROTECTION 7;'&0RGHOV:r):r& 127( 02817,1**$6.(76833/,('1276+2:1 81,76LQ>PP@ 02817,1*; 21%$&.)$&( %(+,1')5217&29(5 $&+($7(532:(5 &21752//(5 /('6 ,03(//(532:(5 $1'$/$50 ,17(5)$&( (1&/2685( $,5,1 (1&/2685( $,5287 5(029$%/( +$1*,1* 7$%6; $0%,(17 $,5287 $0%,(17 $,5,1 3 02817,1*+$5':$5()25,17(5$//<02817(' 02817,1*,6%(+,1'5(029$%/()5217&29(5 ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; +( 287/,1( ; ; ; ; ; ; +(287/,1( &XWRXW'LPHQVLRQV ([WHUQDO0RXQW EQUIPMENT PROTECTION &XWRXW'LPHQVLRQV ,QWHUQDO0RXQW PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 165 Sealed Enclosure Cooling Heat Exchangers 3 Sealed Enclosure Cooling Heat Exchangers 7;$&0RGHOV:r):r& 02817,1*; 21%$&.)$&( %(+,1')5217&29(5 32:(5&25' (175$1&( (1&/2685( $,5,1 5(029$%/( +$1*,1* 7$%6; $0%,(17 $,5287 $0%,(17 $,5,1 (1&/2685( $,5287 ; 02817,1*+$5':$5()25,17(51$//<02817(' 02817,1*,6%(+,1'5(029$%/()5217&29(5 ; ; ; ; ; ; ; ; ; ; ; ; ; &XWRXW'LPHQVLRQV ([WHUQDO0RXQW Cooling ; +(287/,1( 166 ; ; ; ; ; ; ; +(287/,1( &XWRXW'LPHQVLRQV ,QWHUQDO0RXQW SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data TX38 Models 56 W/°F (100 W/°C) CATALOG NUMBER COOLING PERFORMANCE Nominal: W per °F W per °C Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F/°C) Minimum (°F/°C) Airflow at 0 Static Pressure: Internal loop 50 Hz (CFM / m3/hr.) External loop 50 Hz (CFM / m3/hr.) Internal loop 60 Hz (CFM / m3/hr.) External loop 60 Hz (CFM / m3/hr.) ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (W at 50/60 Hz) Max. Nominal Current (A at 50/60 Hz) Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Material Finish UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) EQUIPMENT PROTECTION TX385616100 TX385626100 TX385624100 TX385648100 56 100 N/A N/A 56 100 N/A N/A 56 100 N/A N/A 56 100 N/A N/A 149/65 -40/-40 149/65 -40/-40 149/65 -40/-40 149/65 -40/-40 425/722 461/738 477/810 517/878 425/722 461/738 477/810 517/878 N/A N/A 368/625 422/717 N/A N/A 368/625 422/717 115 VAC 50/60 +/- 10% 368 2.3/3.2 230 VAC 50/60 +/- 10% 276 0.7/1.2 24 VDC 50/60 +/- 10% 207 8.6 48 VDC 50/60 +/- 10% 279 5.8 cUL Listed CE GOST 6-ft. cord with NEMA 5-15 plug 6-ft. cord with NEMA 6-15 plug cUL Listed CE GOST Terminal block Terminal block Type 12, 3R, 4 standard Type 4X optional Type 12, 3R, 4 standard Type 4X optional 64 dBA 64 dBA Mild Mild steel sheet metal standard RAL 7035 light-gray, semi-textured powder-coat paint standard Mild Mild steel sheet metal standard RAL 7035 light-gray, semi-textured powder-coat paint standard 38/965.2 19.7/500.4 10.1/256.5 66/30 38/965.2 19.7/500.4 10.1/256.5 66/30 38/965.2 19.7/500.4 10.1/256.5 66/30 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 3 38/965.2 19.7/500.4 10.1/256.5 66/30 Cooling 167 Sealed Enclosure Cooling Heat Exchangers 3 Sealed Enclosure Cooling Heat Exchangers 7;'&0RGHOV:r):r& $&+($7(5 32:(5 &21752//(5 /('6 02817,1*; 21%$&.)$&( %(+,1')5217&29(5 ; (1&/2685( $,5,1 $0%,(17 $,5287 $0%,(17 $,5,1 ; (1&/2685( $,5287 ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; +(287/,1( ; ; ; ; ; +(287/,1( &XWRXW'LPHQVLRQV ([WHUQDO0RXQW Cooling ; 02817,1*+$5':$5()25,17(51$//<02817(' 02817,1*,6%(+,1'5(029$%/()5217&29(5 168 5(029$%/( +$1*,1* 7$%6; ; ,03(//(532:(5 $1'$/$50 ,17(5)$&( &XWRXW'LPHQVLRQV ,QWHUQDO0RXQW SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION 7;$&0RGHOV:r):r& 127( 02817,1**$6.(76833/,('1276+2:1 81,76LQ>PP@ 02817,1*; 21%$&.)$&( %(+,1')5217&29(5 ; (1&/2685( $,5,1 $0%,(17 $,5287 ; ; ; ; ; ; 3 ; ; ; ; 6; ; ; ; ; ; +(287/,1( &XWRXW'LPHQVLRQV ([WHUQDO0RXQW EQUIPMENT PROTECTION ; ; ; ; ; ; ; 02817,1*+$5':$5()25,17(51$//<02817(' 02817,1*,6%(+,1'5(029$%/()5217&29(5 ; ; (1&/2685( $,5287 $0%,(17 $,5,1 ; 5(029$%/( +$1*,1* 7$%6; 32:(5&25' (175$1&( +(287/,1( &XWRXW'LPHQVLRQV ,QWHUQDO0RXQW PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 169 Sealed Enclosure Cooling Heat Exchangers 3 Sealed Enclosure Cooling Heat Exchangers Performance Data TX52 Models 83 W/°F (150 W/°C) CATALOG NUMBER COOLING PERFORMANCE Nominal: W per °F W per °C Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F/°C) Minimum (°F/°C) Airflow at 0 Static Pressure: Internal loop 50 Hz (CFM / m3/hr.) External loop 50 Hz (CFM / m3/hr.) Internal loop 60 Hz (CFM / m3/hr.) External loop 60 Hz (CFM / m3/hr.) ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (W at 50/60 Hz) Max. Nominal Current (A at 50/60 Hz) Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Material Finish UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) 170 Cooling TX528316100 TX528326100 TX528324100 TX528348100 83 150 N/A N/A 83 150 N/A N/A 83 150 N/A N/A 83 150 N/A N/A 149/65 -40/-40 149/65 -40/-40 149/65 -40/-40 149/65 -40/-40 495/841 540/917 533/905 605/1028 495/841 540/917 533/905 605/1028 N/A N/A 466/792 547/929 N/A N/A 466/792 547/929 115 VAC 50/60 +/- 10% 782 4.3/6.7 230 VAC 50/60 +/- 10% 771 2.2/3.4 24 VDC 50/60 +/- 10% 507 21.1 48 VDC 50/60 +/- 10% 375 7.8 cUL Listed CE GOST 6-ft. cord with NEMA 5-15 plug 6-ft. cord with NEMA 6-15 plug cUL Listed CE GOST Terminal block Terminal block Type 12, 3R, 4 standard Type 4X optional Type 12, 3R, 4 standard Type 4X optional 68 dBA 68 dBA Mild steel sheet metal standard Stainless steel optional RAL 7035 light-gray, semi-textured powder-coat paint standard Mild steel sheet metal standard Stainless steel optional RAL 7035 light-gray, semi-textured powder-coat paint standard 52/1320.8 19.7/500.4 10.1/256.5 100/45.3 52/1320.8 19.7/500.4 10.1/256.5 100/45.3 52/1320.8 19.7/500.4 10.1/256.5 100/45.3 SUBJECT TO CHANGE WITHOUT NOTICE 52/1320.8 19.7/500.4 10.1/256.5 100/45.3 EQUIPMENT PROTECTION 7;'&0RGHOV:r):r& $&+($7(5 32:(5 127( 02817,1**$6.(76833/,('1276+2:1 81,76LQ>PP@ 02817,1*; 21%$&.)$&( %(+,1')5217&29(5 ,03(//(532:(5 $1'$/$50 ,17(5)$&( ; (1&/2685( $,5,1 (1&/2685( $,5287 ; ; ; 3 ; ; &XWRXW'LPHQVLRQV ([WHUQDO0RXQW +(287/,1( ; ; ; ; ; ; ; ; ; ; EQUIPMENT PROTECTION ; ; ; ; ; ; 02817,1*+$5':$5()25,17(51$//<02817(' 02817,1*,6%(+,1'5(029$%/()5217&29(5 ; ; ; ; ; ; ; ; ; ; $0%,(17 $,5,1 ; 5(029$%/( +$1*,1* 7$%6; $0%,(17 $,5287 ; ; +(287/,1( &XWRXW'LPHQVLRQV ,QWHUQDO0RXQW PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 171 Sealed Enclosure Cooling Heat Exchangers 3 Sealed Enclosure Cooling Heat Exchangers 7;$&0RGHOV:r):r& 127( 02817,1**$6.(76833/,('12:6+2:1 81,76LQ>PP@ (1&/2685( $,5287 ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; ; +(287/,1( +(287/,1( &XWRXW'LPHQVLRQV ([WHUQDO0RXQW Cooling ; ; 172 ; ; ; ; ; ; ; ; ; 02817,1*+$5':$5()25,17(51$//<02817(' 02817,1*,6%(+,1'5(029$%/()5217&29(5 ; ; ; $0%,(17 $,5,1 32:(5 &25' (175$1&( ; ; 5(029$%/( +$1*,1* 7$%6; $0%,(17 $,5287 (1&/2685( $,5,1 02817,1*; 21%$&.)$&( %(+,1')5217&29(5 &XWRXW'LPHQVLRQV ,QWHUQDO0RXQW SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Notes 3 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 173 Sealed Enclosure Cooling Heat Exchangers 3 Sealed Enclosure Cooling Heat Exchangers CLIMAGUARD™ AIR-TO-WATER INDOOR WCHE01 2968 BTU/Hr. 870 Watts WCHE04/WCHE06 7506/10577 BTU/Hr. 2200/3100 Watts WCHE14 22861 BTU/Hr. 6700 Watts INDUSTRY STANDARDS FINISH • • UL/cUL Listed; Type 12; File No. SA33866 CE IP55 NOTES APPLICATION • • • • tandard models constructed of rugged steel S R AL 7035 light-gray, powder-coat polyester paint I ndustrial process controls Industrial robotics controls Electronic cabinets in harsh environments Conveyor systems Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. FEATURES • • • • • • • • • • • C apacities ranging from 870 watts to 6700 watts F ilterless design NEMA power cord connection standard Copper pipe and aluminum fins heat exchanger core A ir movers with thermal protection Regulating mechanical thermostat set at 35 C (95 F), differential of 4 C (7 F) Operating temperature from 10-50 C (50-122 F) Solenoid water valve UL Listed to save customers time and money with agency approvals Recovery of condensation system and condensation discharge pipe Requires an available cooled water source 174 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data WCHE01 Models 870 Watt CATALOG NUMBER COOLING PERFORMANCE Nominal: BTU/Hr. @ Δt 25 C Watts @ Δt 25 C Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F/°C) Minimum (°F/°C) Flow at 0 Static Pressure: Internal loop 50 Hz (Airflow: CFM / m3/hr.) External loop 50 Hz (Waterflow: GPM @ 95 F) Internal loop 60 Hz (Airflow: CFM / m3/hr.) External loop 60 Hz (Waterflow: GPM @ 95 F) ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (W at 50/60 Hz) Max. Nominal Current (A at 50/60 Hz) Starting Current (Amps) Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type CONTROLLER Description Thermostat Location Factory Thermostat Setting (°F/°C) SOUND LEVEL At 1.0 Meters UNIT CONSTRUCTION Material Finish UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) WCHE01916002 WCHE01926002 2968 870 NA NA 2968 870 NA NA 122/50 50/10 122/50 50/10 194/330 0.66 194/330 0.66 194/330 0.66 194/330 0.66 115 50/60 +/- 10% 28 0.5 0.7 230 50/60 +/- 10% 28 0.5 0.7 Cord with NEMA 5-15 plug UL/cUL Listed Cord with NEMA 6-15 plug Type 12/IP55 95/35 Type 12/IP55 Basic Mechanical Thermostat Behind front cover, near the fan 58 dBA 95/35 3 58 dBA Mild Steel Sheet Metal Standard RAL 7035 light-gray, semi-textured powder-coat paint standard 15.9/404 12.12/308 4.49/114 19.84/9 15.9/404 12.12/308 4.49/114 19.84/9 Performance Curves for WCHE01 Models 870 Watt 25 30 Cabinet Temperature (°C) 35 40 45 Water Temperature Cooling Capacity (BTU/Hr.) 3992 10 C 50 F 15 C 59 F 50 1370 1170 3310 20 C 68 F 970 2627 25 C 77 F 770 1945 30 C 86 F 570 370 1262 580 EQUIPMENT PROTECTION Cooling Capacity (W) 4675 20 68 77 86 95 104 Cabinet Temperature (°F) PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 113 170 122 Cooling 175 Sealed Enclosure Cooling Heat Exchangers 3 Sealed Enclosure Cooling Heat Exchangers WCHE01 Models 870 Watt )5217 002817,1*+2/(6 %$&. (1&/2685( $,5,1 )705() 32:(5&25':,7+3/8* &21'(16$7( '5$,178%( (1&/2685( $,5287 :$7(5 287 :$7(5 ,1 5() %336*)(0$/( :$7(5&211(&7,21 5() 5() 5() 89091145 &87287',0(16,216 Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. 176 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data WCHE04 Models 2200 Watt CATALOG NUMBER COOLING PERFORMANCE Nominal: BTU/Hr. @ Δt 25 C Watts @ Δt 25 C Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F/°C) Minimum (°F/°C) Flow at 0 Static Pressure: Internal loop 50 Hz (Airflow: CFM / m3/hr.) External loop 50 Hz (Waterflow: GPM @ 95 F) Internal loop 60 Hz (Airflow: CFM / m3/hr.) External loop 60 Hz (Waterflow: GPM @ 95 F) ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (W at 50/60 Hz) Max. Nominal Current (A at 50/60 Hz) Starting Current (Amps) Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type CONTROLLER Description Thermostat Location Factory Thermostat Setting (°F/°C) SOUND LEVEL At 1.0 Meters UNIT CONSTRUCTION Material Finish UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) WCHE04916002 WCHE04926002 7506 2200 NA NA 7506 2200 NA NA 122/50 50/10 122/50 50/10 339/575 0.66 339/575 0.66 339/575 0.66 339/575 0.66 115 50/60 +/- 10% 90 0.8 1 230 50/60 +/- 10% 90 0.8 1 Cord with NEMA 5-15 plug UL/cUL Listed Cord with NEMA 6-15 plug Type 12/IP55 95/35 Type 12/IP55 Basic Mechanical Thermostat Behind front cover, near the fan 58 dBA 95/35 3 58 dBA Mild Steel Sheet Metal Standard RAL 7035 light-gray, semi-textured powder-coat paint standard 36.41/925 15.75/400 8.07/205 44.1/20 36.41/925 15.75/400 8.07/205 44.1/20 20 12284 11601 10919 10236 9554 8872 8189 7507 6824 6142 5459 4777 4095 3412 2730 2047 1365 68 EQUIPMENT PROTECTION 25 30 Cabinet Temperature (°C) 35 40 45 Water Temperature 50 10 C 50 F 15 C 59 F 20 C 68 F 25 C 77 F 30 C 86 F 77 86 95 104 Cabinet Temperature (°F) PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 113 3600 3400 3200 3000 2800 2600 2400 2200 2000 1800 1600 1400 1200 1000 800 600 400 122 Cooling Capacity (W) Cooling Capacity (BTU/Hr.) Performance Curves for WCHE04 Models 2200 Watt Cooling 177 Sealed Enclosure Cooling Heat Exchangers 3 Sealed Enclosure Cooling Heat Exchangers WCHE04 Models 2200 Watt )5217 (1&/2685( $,5,1 )705() 32:(5&25':,7+3/8* &21'(16$7( '5$,178%( 002817,1*+2/(6 (1&/2685( $,5287 5() %336*)(0$/( :$7(5&211(&7,21 :$7(5 :$7(5 ,1 287 5() 5() 5() 5() 89091146 &87287',0(16,216 Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. 178 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data WCHE06 Models 3100 Watt CATALOG NUMBER COOLING PERFORMANCE Nominal: BTU/Hr. @ Δt 25 C Watts @ Δt 25 C Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F/°C) Minimum (°F/°C) Flow at 0 Static Pressure: Internal loop 50 Hz (Airflow: CFM / m3/hr.) External loop 50 Hz (Waterflow: GPM @ 95 F) Internal loop 60 Hz (Airflow: CFM / m3/hr.) External loop 60 Hz (Waterflow: GPM @ 95 F) ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (W at 50/60 Hz) Max. Nominal Current (A at 50/60 Hz) Starting Current (Amps) Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type CONTROLLER Description Thermostat Location Factory Thermostat Setting (°F/°C) SOUND LEVEL At 1.0 Meters UNIT CONSTRUCTION Material Finish UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) WCHE06916002 WCHE06926002 10577 3100 NA NA 10577 3100 NA NA 122/50 50/10 122/50 50/10 507/860 2.2 507/860 2.2 507/860 2.2 507/860 2.2 115 50/60 +/- 10% 110 2 2.4 230 50/60 +/- 10% 115 1 1.2 Cord with NEMA 5-15 plug UL/cUL Listed Cord with NEMA 6-15 plug Type 12/IP55 95/35 Type 12/IP55 Basic Mechanical Thermostat Behind front cover, near the fan 58 dBA 95/35 3 58 dBA Mild Steel Sheet Metal Standard RAL 7035 light-gray, semi-textured powder-coat paint standard 36.41/925 15.75/400 8.07/205 46.3/21 36.41/925 15.75/400 8.07/205 46.3/21 17061 16378 15696 15013 14331 13649 12966 12284 11601 10919 10236 9554 8872 8189 7507 6824 6142 5459 4777 4095 3412 2730 2047 20 25 30 Cabinet Temperature (°C) 35 40 45 Water Temperature 50 10 C 50 F 15 C 59 F 20 C 68 F 25 C 77 F 30 C 86 F 68 EQUIPMENT PROTECTION 77 86 95 104 Cabinet Temperature (°F) PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 113 5000 4800 4600 4400 4200 4000 3800 3600 3400 3200 3000 2800 2600 2400 2200 2000 1800 1600 1400 1200 1000 800 600 122 Cooling Capacity (W) Cooling Capacity (BTU/Hr.) Performance Curves for WCHE06 Models 3100 Watt Cooling 179 Sealed Enclosure Cooling Heat Exchangers 3 Sealed Enclosure Cooling Heat Exchangers WCHE06 Models 3100 Watt )5217 (1&/2685( $,5,1 )705() 32:(5&25':,7+3/8* &21'(16$7( '5$,178%( 002817,1*+2/(6 (1&/2685( $,5287 %336*)(0$/( :$7(5&211(&7,21 5() :$7(5 :$7(5 ,1 287 5() 5() 5() 5() 89091147 &87287',0(16,216 Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. 180 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data WCHE14 Models 6700 Watt CATALOG NUMBER COOLING PERFORMANCE Nominal: BTU/Hr. @ Δt 25 C Watts @ Δt 25 C Refrigerant Refrigerant Charge (ounces/grams) Operating Temperature Range: Maximum (°F/°C) Minimum (°F/°C) Flow at 0 Static Pressure: Internal loop 50 Hz (Airflow: CFM / m3/hr.) External loop 50 Hz (Waterflow: GPM @ 95 F) Internal loop 60 Hz (Airflow: CFM / m3/hr.) External loop 60 Hz (Waterflow: GPM @ 95 F) ELECTRICAL DATA Rated Voltage Frequency (Hz) Operating Range Max. Power Consumption (W at 50/60 Hz) Max. Nominal Current (A at 50/60 Hz) Starting Current (Amps) Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type CONTROLLER Description Thermostat Location Factory Thermostat Setting (°F/°C) SOUND LEVEL At 1.0 Meters UNIT CONSTRUCTION Material Finish UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) WCHE14916002 WCHE14926002 22861 6700 NA NA 22861 6700 NA NA 122/50 50/10 122/50 50/10 855/1450 3.78 855/1450 3.78 855/1450 3.78 855/1450 3.78 115 50/60 +/- 10% 200 2 2.4 230 50/60 +/- 10% 245 1.3 1.4 Cord with NEMA 5-15 plug UL/cUL Listed Cord with NEMA 6-15 plug Type 12/IP55 Type 12/IP55 Basic Mechanical Thermostat Behind front cover, near the fan 95/35 58 dBA 95/35 3 58 dBA Mild Steel Sheet Metal Standard RAL 7035 light-gray, semi-textured powder-coat paint standard 43.34/1101 19.72/501 11.81/300 86/39 43.34/1101 19.72/501 11.81/300 86/39 37534 36169 34804 33439 32074 30709 29344 27980 26615 25250 23885 22520 21155 19790 18426 17061 15696 14331 12966 11601 10236 8872 7507 6142 4777 20 25 30 Cabinet Temperature (°C) 35 40 45 Water Temperature 10 C 50 F 15 C 59 F 20 C 68 F 25 C 77 F 30 C 86 F 68 EQUIPMENT PROTECTION 77 86 95 104 Cabinet Temperature (°F) PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 113 50 11000 10600 10200 9800 9400 9000 8600 8200 7800 7400 7000 6600 6200 5800 5400 5000 4600 4200 3800 3400 3000 2600 2200 1800 1400 122 Cooling Capacity (W) Cooling Capacity (BTU/Hr.) Performance Curves for WCHE14 Models 6700 Watt Cooling 181 Sealed Enclosure Cooling Heat Exchangers 3 Sealed Enclosure Cooling Heat Exchangers WCHE14 Models 6700 Watt 002817,1*+2/(6 (1&/2685( $,5,1 )5217 )705() 32:(5&25':,7+3/8* (1&/2685( $,5287 &21'(16$7( '5$,178%( 5() :$7(5 :$7(5 ,1 287 %336*)(0$/( :$7(5&211(&7,21 5() 5() 5() 5() 89091148 5() &87287',0(16,216 Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. 182 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Notes 3 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 183 Sealed Enclosure Cooling Heat Exchangers 3 Sealed Enclosure Cooling Thermoelectric Coolers THERMOELECTRIC COOLERS INDOOR/OUTDOOR THERMOELECTRIC COOLERS Unshrouded 60, 100 and 200 Watts Shrouded 60, 100 and 200 Watts INDUSTRY STANDARDS ACCESSORIES UR, cUR Recognized; Type 12, 3R, 4, 4X; File No. SA6453 • ptional thermolelectric temperature controller regulates O cooling and heating automatically Optional thermoelectric condenser manager helps direct condensation to the bottom of the enclosure CE IP 65 • APPLICATION NOTES Thermoelectric Coolers minimize downtime and component loss by removing heat around critical components within an enclosure. These compact, low-profile coolers using the Peltier effect allow for cooling of small indoor and outdoor enclosures. No condensers, compressors or filters are required making it a reliable solution for demanding low-maintenance environments. Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. FEATURES • • • • • • • • • • C Powered operation for 24V and 48V applications D Low profile design allows for mounting vertically and horizontally on any enclosure to avoid interference with internal components F ilterless design reduces maintenance requirements Contains no refrigerant, making it earth friendly Prewired with simple terminal block for easy wiring connections Operates on the Peltier effect for cooling or heating Compressor-free air conditioning for demanding indoor and outdoor applications Shrouded and unshrouded models included in standard packages Operating temperature range -40 C (-40 F) to 55 C (131 F) P artial recess mount SPECIFICATIONS • Models 60 Watt, 24 Volt 100 Watt, 24/48 Volt 200 Watt, 24/48 Volt FINISH • hrouded finish includes both powder coat paint RAL 7035 light S gray standard and stainless steel 304 184 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data TE09 60W 204 BTU/Hr. (24 V) CATALOG NUMBERS Description Catalog Number COOLING PERFORMANCE BTU/Hr. Watts Operating Temperature Range: Maximum (°C / °F) Minimum (°C / °F) Air Flow at 0 Static Pressure: Internal loop (CFM / M3/Hr.) External loop (CFM / M3/Hr.) Nominal Heating Watts ELECTRICAL DATA Input DC Voltage Nominal (VDC) Minimum (VDC) Maximum (VDC) Power Consumption 95 F / 95 F (35 C / 35 C) Max Current (Amps) Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type / IP Rating SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Heat Sink Material Shroud Material Shroud Finish UNIT DIMENSIONS Height (in. / mm) Width (in. / mm) Depth (in. / mm) Weight (lb. / kg) EQUIPMENT PROTECTION 24V w/o shroud TE090624020 24V w/ painted shroud TE090624010 24V w/ SS shroud TE090624011 178 52 178 52 178 52 55 / 131 -40 / -40 55 / 131 -40 / -40 55 / 131 -40 / -40 24 / 41 80 / 136 64 24 / 41 80 / 136 64 24 / 41 80 / 136 64 24 18 27.6 89 4.4 UR, cUR Recognized CE Terminal Block 24 18 27.6 89 4.4 UR, cUR Recognized CE Terminal Block 24 18 27.6 89 4.4 UR, cUR Recognized CE Terminal Block Type 12,3R,4,4X / IP 65 Type 12,3R,4 / IP 65 Type 12,3R,4,4X / IP 65 65 dBA 65 dBA 65 dBA Anodized Aluminum N/A N/A Anodized Aluminum Galvanized Steel RAL 7035 light-gray, semi-textured powder-coat paint standard Anodized Aluminum Stainless Steel No. 4 Brushed Finish 9.29/236 5.02/128 6.94/176 7.80/3.60 9.29/236 5.02/128 6.94/176 7.80/3.60 9.06/230 4.84/123 6.91/176 6.00/2.70 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 3 Cooling 185 Sealed Enclosure Cooling Thermoelectric Coolers 3 Sealed Enclosure Cooling Thermoelectric Coolers :9 0;; :9 0;; [ &XWRXW'LPHQVLRQV 186 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data TE12 100W 341 BTU/Hr. (24/48 V) CATALOG NUMBERS Description Catalog Number COOLING PERFORMANCE BTU/Hr. Watts Operating Temperature Range: Maximum (°C / °F) Minimum (°C / °F) Air Flow at 0 Static Pressure: Internal loop (CFM / M3/Hr.) External loop (CFM / M3/Hr.) Nominal Heating Watts ELECTRICAL DATA Input DC Voltage Nominal (VDC) Minimum (VDC) Maximum (VDC) Power Consumption 95 F / 95 F (35 C / 35 C) Max Current (Amps) Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type / IP Rating SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Heat Sink Material Shroud Material Shroud Finish UNIT DIMENSIONS Height (in. / mm) Width (in. / mm) Depth (in. / mm) Weight (lb. / kg) EQUIPMENT PROTECTION 24V w/o shroud TE121024020 24V w/ painted shroud TE121024010 24V w/ SS shroud TE121024011 48V w/o shroud TE121048020 48V w/ painted shroud TE121048010 321 94 321 94 321 94 321 94 321 94 55 / 131 -40 /-40 55 / 131 -40 /-40 55 / 131 -40 /-40 55 / 131 -40 /-40 55 / 131 -40 /-40 62 / 105 86 / 146 94 62 / 105 86 / 146 94 62 / 105 86 / 146 94 62 / 105 86 / 146 94 62 / 105 86 / 146 94 24 18 27.6 162 24 18 27.6 162 24 18 27.6 162 48 40 56.7 162 48 40 56.7 162 8.5 UR, cUR Recognized CE GOST Terminal Block 8.5 UR, cUR Recognized CE GOST Terminal Block 8.5 UR, cUR Recognized CE GOST Terminal Block 4.4 UR, cUR Recognized CE GOST Terminal Block 4.4 UR, cUR Recognized CE GOST Terminal Block Type 12,3R,4,4X / IP 65 Type 12,3R,4 / IP 65 68 dBA 68 dBA 68 dBA 68 dBA 68 dBA Anodized Aluminum N/A N/A Anodized Aluminum Galvanized Steel RAL 7035 light-gray, semi-textured powder-coat paint standard Anodized Aluminum Stainless Steel No. 4 Brushed Finish Anodized Aluminum N/A N/A Anodized Aluminum Galvanized Steel RAL 7035 light-gray, semi-textured powder-coat paint standard 11.81/300 6.02/153 7.40/188 8.50/3.90 12.00/305 6.18/157 7.43/189 11.00/5.00 12.00/305 6.18/157 7.43/189 11.00/5.00 11.81/300 6.02/153 7.40/188 8.50/3.90 12.00/305 6.18/157 7.43/189 11.00/5.00 Type 12,3R,4,4X / IP 65 Type 12,3R,4,4X / IP 65 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Type 12,3R,4 / IP 65 Cooling 187 3 Sealed Enclosure Cooling Thermoelectric Coolers 3 Sealed Enclosure Cooling Thermoelectric Coolers :9 25 >@>@ 0;; :9 25 >@>@ 0;; [ &XWRXW'LPHQVLRQV 188 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data TE16 200W 682 BTU/Hr. (24/48 V) CATALOG NUMBERS Description Catalog Number COOLING PERFORMANCE BTU/Hr. Watts Operating Temperature Range: Maximum (°C / °F) Minimum (°C / °F) Air Flow at 0 Static Pressure: Internal loop (CFM / M3/Hr.) External loop (CFM / M3/Hr.) Nominal Heating Watts ELECTRICAL DATA Input DC Voltage Nominal (VDC) Minimum (VDC) Maximum (VDC) Power Consumption 95 F / 95 F (35 C / 35 C) Max Current (Amps) Agency Approvals Power Input Description ENCLOSURE PROTECTION UL Type / IP Rating SOUND LEVEL At 1.5 Meters UNIT CONSTRUCTION Heat Sink Material Shroud Material Shroud Finish UNIT DIMENSIONS Height (in. / mm) Width (in. / mm) Depth (in. / mm) Weight (lb. / kg) EQUIPMENT PROTECTION 24V w/o shroud TE162024020 24V w/ painted shroud TE162024010 24V w/ SS shroud TE162024011 48V w/o shroud TE162048020 48V w/ painted shroud TE162048010 567 166 567 166 567 166 567 166 567 166 55 / 131 -40 /-40 55 / 131 -40 /-40 55 / 131 -40 /-40 55 / 131 -40 /-40 55 / 131 -40 /-40 62 / 105 86 / 146 146 62 / 105 86 / 146 146 62 / 105 86 / 146 146 62 / 105 86 / 146 146 62 / 105 86 / 146 146 24 18 27.6 295 24 18 27.6 295 24 18 27.6 295 48 40 56.7 295 48 40 56.7 295 14.7 UR, cUR Recognized CE GOST Terminal Block 14.7 UR, cUR Recognized CE GOST Terminal Block 14.7 UR, cUR Recognized CE GOST Terminal Block 7.6 UR, cUR Recognized CE GOST Terminal Block 7.6 UR, cUR Recognized CE GOST Terminal Block Type 12,3R,4,4X / IP 65 Type 12,3R,4 / IP 65 68 dBA 68 dBA 68 dBA 68 dBA 68 dBA Anodized Aluminum N/A N/A Anodized Aluminum Galvanized Steel RAL 7035 light-gray, semi-textured powder-coat paint standard Anodized Aluminum Stainless Steel No. 4 Brushed Finish Anodized Aluminum N/A N/A Anodized Aluminum Galvanized Steel RAL 7035 light-gray, semi-textured powder-coat paint standard 15.75/400 7.09/180 7.25/184 14.80/6.70 15.93/405 7.35/187 7.27/185 18.60/8.40 15.93/405 7.35/187 7.27/185 18.60/8.40 15.75/400 7.09/180 7.25/184 14.80/6.70 15.93/405 7.35/187 7.27/185 18.60/8.40 Type 12,3R,4,4X / IP 65 Type 12,3R,4,4X / IP 65 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Type 12,3R,4 / IP 65 Cooling 189 3 Sealed Enclosure Cooling Thermoelectric Coolers 3 Sealed Enclosure Cooling Thermoelectric Coolers :9 25 >@>@ 7+58+2/(; :9 25 >@>@ [ 0; &XWRXW'LPHQVLRQV 190 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Cooling Capacity versus Temperature D at 35 C (95 F) Ambientifference -27 F 1000 BTU/hr -18 F -9 F 0F 9F 18 F 27 F 293 W TE0906XXXXX TE1210XXXXX Cooling Capacity 800 BTU/hr TE1620XXXXX 234 W 600 BTU/hr 176 W 400 BTU/hr 117 W 200 BTU/hr 59 W 0W 0 BTU/hr -15 C 3 -10 C -5 C 0C 5C 10 C 15 C Temperature Difference (Inside - Outside) EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 191 Sealed Enclosure Cooling Thermoelectric Coolers 3 Sealed Enclosure Cooling Thermoelectric Coolers THERMOELECTRIC TEMPERATURE CONTROLLER FEATURES • • • • • • • • rovides PWM regulation of cooling and heating output for P Thermoelectric Cooler Automatically switches between cooling and heating Six cooling temperature set points range from 22.5 C (72.5 F) to 35 C (95 F) (35 C factory setting) S even heating temperature set points range from -15 C (5 F) to 15 C (59 F)(15 C factory setting) Heating function can be easily disabled if desired LEDs indicate cooling and heating mode, low and high temperature alarms, and overall system status Dry contact relay output provides for external alarm indication Can be mounted in a convenient dry location near the thermoelectric cooler; mounting hardware included FINISH • R AL 7035 light-gray powder-coat painted galvanized steel Performance Data CATALOG NUMBERS ELECTRICAL DATA Rated Voltage (VDC) Operating Range (VDC) Current @ Rated Voltage (Amps) Power (Watts) Operating Temperature Range Maximum (°F/°C) Minimum (°F/°C) UNIT CONSTRUCTION Material Finish UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth - overall (in./mm) Depth - enclosure (in/mm) Weight (lb./kg) TEC24VCNTLR TEC48VCNTLR 24 18 to 30 17.2 48 40 to 60 8.6 410 149/65 -40/-40 Steel RAL 7035 light-gray, semi-textured powder-coat paint standard 6.50/165.0 6.12/155.5 2.50/63.5 1.75/44.5 3.0/1.6 9DQG97(&&RQWUROOHUV ; 192 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION THERMOELECTRIC CONDENSATE MANAGER INDUSTRY STANDARDS FINISH Maintains UL/cUL Type 3R, 12, 4 and 4X rating when properly installed FEATURES • • • • • • I ncludes all required hardware and vent drain Maintains the ingerity of Type 4 or Type 4X enclosure Drains condensation to bottom of enclosure via vent drain (vent drain included with package) Utilizes existing mounting holes and fasteners of thermoelectric cooler that requires no additional mounting an Material Galvanzied steel polyester powder coat paint with P RAL 7035 Vent drain material options include stainless steel or nonmetallic 3 Performance Data CATALOG NUMBERS Fits TEC Unit Model UNIT CONSTRUCTION Pan Material Pan Finish Vent Drain Material UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) EQUIPMENT PROTECTION TEC60WCMSS4 All TE09 Stainless Steel .75/19 5.50/140 2.50/64 TEC60WCMNM All TE09 TEC100WCMSS4 All TE12 TEC100WCMNM All TE12 TEC200WCMSS4 All TE16 Galvanized Steel RAL 7035 light-gray, semi-textured powder-coat paint standard Non-Metallic Stainless Steel Non-Metallic Stainless Steel .75/19 5.50/140 2.50/64 .75/19 6.25/159 2.50/64 .75/19 6.25/159 2.50/64 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM .75/19 7.44/189 2.50/64 TEC200WCMNM All TE16 Non-Metallic .75/19 7.44/189 2.50/64 Cooling 193 Sealed Enclosure Cooling Thermoelectric Coolers 3 Sealed Enclosure Cooling Vortex Coolers VORTEX COOLERS INDOOR/OUTDOOR VORTEX COOLERS INDUSTRY STANDARDS NEMA Type 4 Models: Maintains UL/cUL Type 4 when properly installed on a UL/cUL Type 4 enclosure. UL508 Listed; Type 4; File No. E187045 NEMA Type 4X Models: Maintains UL/cUL Type 4X when properly installed on a UL/cUL Type 4X enclosure. FINISH Brushed satin aluminum or stainless steel ACCESSORIES (for the enclosure) Can be installed on all enclosure product families. Separate accessories include an in-line oil filter. Compressed Air In (70 F/21 C) UL508 Listed; Type 4X; File No. E187045 NEMA Type 12 Models: Maintains UL/cUL Type 12 when properly installed on a UL/cUL Type 12 enclosure. UL508 Listed; Type 12; File No. E187045 Vortex Tube Control Valve Cold Air Outlet Hot Air Outlet Vortex Generation Chamber APPLICATION Powered by compressed air, Vortex Cooling Systems generate chilled air to cool small enclosures without refrigerants or moving parts. These systems are exceptionally reliable and low maintenance, even in the harshest and dirtiest environments. Vortex Tube Air Flow Schematic FEATURES • • • • F ive-micron airline filter, 115 V solenoid Thermostat Ducting kit Cooling capacities to 2500 BTU/Hr. (733 W) 194 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data VC Series NEMA Type 12 CATALOG NUMBERS Aluminum COOLING PERFORMANCE Cooling Capacity (BTU/Hr.) Cooling Capacity (Watts) Compressed Air Consumption (SCFM) Compressed Air Consumption (L3/M) SOUND LEVEL Noise Level (dB) ENCLOSURE PROTECTION UL Type ELECTRICAL DATA Rated Voltage Frequency (Hz) UNIT DIMENSIONS Weight (lb./kg) VC0416012 VC0916012 VC1516012 VC2516012 400 117 8 227 900 264 15 425 1500 440 25 708 2500 733 35 991 69 80 83 90 Type 12 115 50/60 115 50/60 115 50/60 115 50/60 5/2.27 6/2.72 6/2.72 6/2.72 Performance Data VC Series NEMA Type 4, 4X CATALOG NUMBERS Aluminum Stainless Steel COOLING PERFORMANCE Cooling Capacity (BTU/Hr.) Cooling Capacity (Watts) Compressed Air Consumption (SCFM) Compressed Air Consumption (L3/M) SOUND LEVEL Noise Level (dB) ENCLOSURE PROTECTION UL Type ELECTRICAL DATA Rated Voltage Frequency (Hz) UNIT DIMENSIONS Weight (lb./kg) VC0916004 VC091604X VC1716004 VC171604X VC2516004 VC251604X 900 264 15 425 1700 498 25 708 2500 733 35 991 83 86 90 3 Type 4, 4X 115 50/60 115 50/60 115 50/60 6/2.72 6/2.72 6/2.72 Vortex Cooling System Accessories CATALOG NUMBERS PERFORMANCE Description Use with VCool Model Capacity EQUIPMENT PROTECTION VCOF17 Up to 1700 BTU/Hr. VCOF25 Oil Filter PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 2500 BTU/Hr. Cooling 195 Sealed Enclosure Cooling Vortex Coolers 3 Sealed Enclosure Cooling Vortex Coolers 7\SLFDO,QVWDOODWLRQ 9RUWH[&RROHU 6ROHQRLG9DOYH 1371RUPDOO\&ORVHG 1(0$RU;5DWHG 9+]RU9+] 0LFURQ)LOWHU 6XSSOLHG $LUIORZ &ROG$LU 'XFWLQJ.LW 7KHUPRVWDW 1 3 196 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Notes 3 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 197 Sealed Enclosure Cooling Vortex Coolers 3 Sealed Enclosure Cooling Vortex Coolers QUIET VORTEX A/C ENCLOSURE COOLERS, TYPE 4/4X/12 VA09, VA15, VA25 NEMA Type 4/4X VA09, VA15, VA25 NEMA Type 12 VA50 NEMA Type 12 VA50 NEMA Type 4/4X INDUSTRY STANDARDS FEATURES NEMA Type 4,4X Models: Maintains UL/cUL Type 4, 4X when properly installed on a UL/ cUL Type 4, 4X enclosure. UL508 Listed; Type 4, 4X; File No. E249700 NEMA Type 12 Models: Maintains UL/cUL Type 12 when properly installed on a UL/cUL Type 12 enclosure. UL508 Listed; Type 12; File No. E249700 APPLICATION Cooling • • • • echanical thermostat reduces energy consumption M Top, side, and front mount allows for versatile installation in confined areas Quieter operation with noise level of 60-75 dB Cooling capacities up to 5000 BTU/Hr. (1465 W) Supplied with five-micron, automatic drain compressed air filter, cold ducting kit, and cold air muffler Operates in environments up to 175 F (80 C) FINISH • • Vortex A/C Enclosure Coolers keep enclosures cool, clean and protected even in the harshest environments. Offering flexible installation, these enclosure coolers are ideal in space-restrictive areas where compressed air is readily available. With almost no moving parts, these enclosure coolers are highly reliable and virtually maintenance free. 198 • • EMA Type 4,4X models: Polycarbonate and stainless steel N exterior; aluminum and brass internal components NEMA Type 12 models: Polycarbonate and aluminum exterior; aluminum and brass internal components ACCESSORIES • • • • • Oil Removal Filter Generator Kit F ive-micron Air Filter Cold Air Ducting Kit Cold Air Muffler SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data VA Series NEMA Type 4, 4X CATALOG NUMBERS COOLING PERFORMANCE Cooling Capacity (BTU/Hr.) Cooling Capacity (Watts) Compressed Air Consumption (SCFM) Compressed Air Consumption (SLPM) SOUND LEVEL Noise Level (dB) ENCLOSURE PROTECTION UL Type UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) VA091604X VA151604X VA251604X VA501604X 900 264 15 425 1500 440 25 708 2500 733 35 991 5000 1465 70 1982 60 66 72 75 8.00/203 4.75/121 5.38/137 6.4/2.90 6.44/164 9.44/240 5.56/141 11.0/4.99 Type 4, 4X 8.00/203 4.75/121 5.38/137 6.3/2.86 8.00/203 4.75/121 5.38/137 6.3/2.86 VA09, VA15, VA25, Type 4/4X Filter (supplied) 5.88 149 mm Vent Air 3 Hole 1.94 (49 mm) 1.75 (44 mm) diameter x 3.59 (91 mm) long muffler and mounting clamps (supplied) Ducting (supplied) VA50, Type 4/4X Filter (supplied) 6.38 162 mm Vent Air Holes 1.94 (49 mm) 1.75 (44 mm) diameter x 3.59 (91 mm) long muffler and mounting clamps (supplied) Ducting (supplied) EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 199 Sealed Enclosure Cooling Vortex Coolers 3 Sealed Enclosure Cooling Vortex Coolers Performance Data VA Series NEMA Type 12 CATALOG NUMBERS COOLING PERFORMANCE Cooling Capacity (BTU/Hr.) Cooling Capacity (Watts) Compressed Air Consumption (SCFM) Compressed Air Consumption (SLPM) SOUND LEVEL Noise Level (dB) ENCLOSURE PROTECTION UL Type UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) VA0916012 VA1516012 VA2516012 VA5016012 900 264 15 425 1500 440 25 708 2500 733 35 991 5000 1465 70 1982 60 66 72 75 8.00/203 4.75/121 3.56/90 5.0/2.27 6.44/164 9.44/240 4.25/108 7.7/3.50 Type 12 8.00/203 4.75/121 3.56/90 4.9/2.22 8.00/203 4.75/121 3.56/90 4.9/2.22 VA09, VA15, VA25, Type 12 Filter (supplied) 5.88 149 mm Vent Air Hole 1.94 (49 mm) 1.75 (44 mm) diameter x 3.59 (91 mm) long muffler and mounting clamps (supplied) Ducting (supplied) VA50, Type 12 Filter (supplied) 6.38 162 mm Vent Air Holes 1.94 (49 mm) 1.75 (44 mm) diameter x 3.59 (91 mm) long muffler and mounting clamps (supplied) Ducting (supplied) 200 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Vortex AC Accessories Type 4/4X/12 CATALOG NUMBERS Air Filters VAAF15 VAAF25 VAAF50 Oil Filters VCOF17 VCOF25 Generators VAGK09 VAGK15 VAGK25 Air Ducting VADK124X Description Use with VA Model Capacity 5 micron, automatic drain compressed air filter 5 micron, automatic drain compressed air filter 5 micron, automatic drain compressed air filter Up to 1500 BTU/Hr. Up to 2500 BTU/Hr. Up to 5000 BTU/Hr. Oil Filter Oil Filter Up to 1500 BTU/Hr. Up to 5000 BTU/Hr. Generator Kit Generator Kit Generator Kit 900 BTU/Hr. models 1500 BTU/Hr. models 2500 and 5000 BTU/Hr. models Cold Air Ducting Kit All NEMA 12, 4/4X models 3 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 201 Sealed Enclosure Cooling Vortex Coolers 3 Sealed Enclosure Cooling Vortex Coolers VORTEX A/C ENCLOSURE COOLERS, HAZARDOUS LOCATION APPLICATION Hazardous Location Vortex A/C Enclosure Coolers keep enclosures cool, clean and protected even in hazardous environments. These systems are ideal for applications where compressed air is available in Hazardous Locations. With almost no moving parts, these systems are highly reliable and virtually maintenance free. FEATURES • • • • • • pproved for a 175 F (80 C) maximum ambient temperature in A Class I, Div. 2; Class II, Div. 2; and Class III areas Mechanical thermostat reduces energy consumption Top, side, and front mount allows for versatile installation in confined areas Quieter operation with noise level of 60-75 dB Supplied with five-micron, automatic drain compressed air filter, cold ducting kit, cold air muffler, and check valve Cooling capacities up to 5000 BTU/Hr. (1465 W) FINISH • VHL09, VHL15, VHL25 olycarbonate and stainless steel exterior with aluminum and P brass internal components ACCESSORIES • • • • • • • VHL50 Oil Removal Filter Generator Kit 5 micron Air Filter Cold Air Ducting Kit Cold Air Muffler Check Valve Purge System INDUSTRY STANDARDS Hazardous Location Models: UL Classified for Class 1, Div. 2, Groups A through D; Class II, Div. 2, Groups F & G; and Class III locations (when used with an approved purge/pressurization system); File No. E364567. Maintains UL/cUL Type 4, 4X when properly installed on a UL/ cUL Type 4, 4X enclosure. Performance Data VHL Series for Hazardous Locations CATALOG NUMBERS COOLING PERFORMANCE Cooling Capacity (BTU/Hr.) Cooling Capacity (Watts) Compressed Air Consumption (SCFM) Compressed Air Consumption (SLPM) SOUND LEVEL Noise Level (dB) ENCLOSURE PROTECTION UL Classified UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) 202 Cooling VHL09160 VHL15160 VHL25160 VHL50160 900 264 15 425 1500 440 25 708 2500 733 35 991 5000 1465 70 1982 60 66 72 75 Class 1, Div. 2, Groups A-D; Class II, Div. 2, Groups F & G, Class III 8.00/203 4.75/121 5.38/137 6.70/3.04 8.00/203 4.75/121 5.38/137 6.7/3.04 SUBJECT TO CHANGE WITHOUT NOTICE 8.00/203 4.75/121 5.38/137 6.8/3.08 6.44/164 9.44/240 5.56/141 11.4/5.17 EQUIPMENT PROTECTION VHL09, VHL15, VHL25 HAZLOC Filter (supplied) 5.44 138 mm Minimum Purge System (order separately) Vent Air Cut 1.94 (49 mm) hole in enclsoure to install unit 1.25 (32 mm) diameter x 3.06 (78 mm) long check valve assembly (supplied) 1.75 (44 mm) diameter x 3.84 (98 mm) long muffler and mounting clamps (supplied) Ducting (supplied) VHL50 HAZLOC 3 Filter (supplied) Purge System (order separately) 6.38 162 mm Vent Air Holes 1.94 (49 mm) 1.25 (32 mm) diameter x 3.06 (78 mm) long check valve assembly (supplied) 1.75 (44 mm) diameter x 3.88 (98 mm) long muffler and mounting clamps (supplied) Ducting (supplied) Vortex AC Accessories Hazardous Location CATALOG NUMBERS Air Filters VAAF15 VAAF25 VAAF50 Oil Filters VCOF17 VCOF25 Generators VAGK09 VAGK15 VAGK25 Air Ducting VHLDK EQUIPMENT PROTECTION Description Use with VHL Model Capacity 5 micron, automatic drain compressed air filter 5 micron, automatic drain compressed air filter 5 micron, automatic drain compressed air filter Up to 1500 BTU/Hr. Up to 2500 BTU/Hr. Up to 5000 BTU/Hr. Oil Filter Oil Filter Up to 1500 BTU/Hr. Up to 5000 BTU/Hr. Generator Kit Generator Kit Generator Kit 900 BTU/Hr. models 1500 BTU/Hr. models 2500 and 5000 BTU/Hr. models Cold Air Ducting Kit All Hazardous Location models PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 203 Sealed Enclosure Cooling Vortex Coolers COOLING FRESH AIR ENCLOSURE COOLING 4 763.422.2211 763.576.3200 Intro Page CHAPTER 4 FRESH AIR ENCLOSURE COOLING FEATURED PRODUCTS 204 Cooling DIRECT AIR COOLING SYSTEMS (DACS) DACS provides flexible, effective heat removal for outdoor enclosures. A cost-efficient alternative to closed-loop cooling solutions, DACS utilizes quiet, fan-based technology to draw filtered ambient air into the enclosure to dissipate heat. Models include Hydrophobic Gore™ and MERV 12 filtration styles to protect against outdoor elements such as water, dust, bugs and rain. SUBJECT TO CHANGE WITHOUT NOTICE FILTER FANS Filter Fans cool a wide range of heat loads in applications ranging from industrial drives to process equipment and controls. With more than 175 models, Type 12, Type 3R and Type 1 options, a wide range of airflow capabilities and various mounting options, Filter Fans are available for diverse environments. EQUIPMENT PROTECTION CHAPTER CONTENTS Intro Page DIRECT AIR COOLING SYSTEMS (DACS) DACS Outdoor. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 206 FILTER FANS SF Side-Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 212 ST Thin Side-Mount. . . . . . . . . . . . . . . . . . . . . . . . . . . . .230 SR Top-Mount. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236 Filter Fan Shrouds. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240 SF/ST Replacement Filters. . . . . . . . . . . . . . . . . . . . . . . 241 TFP Side-Mount . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242 TFP Exhaust Grilles. . . . . . . . . . . . . . . . . . . . . . . . . . . . .246 TFP Optional Grilles and Replacement Filters . . . . . . . . 246 TFP EMC Upgrade Kit . . . . . . . . . . . . . . . . . . . . . . . . . . . 247 Outdoor Filter Fan and Exhaust Package . . . . . . . . . . . . 248 AXIAL FANS AND ACCESSORIES Compact Axial Fans . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fan Cords. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Fan Cords With Inline Thermostat . . . . . . . . . . . . . . . . . Fan Filter and Finger Guard Kit. . . . . . . . . . . . . . . . . . . . Fan Brackets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Finger Guards. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250 254 254 254 255 255 FAN TRAYS Rack-Mountable Assemblies . . . . . . . . . . . . . . . . . . . . . 256 19-in. Rack-Mountable Tray. . . . . . . . . . . . . . . . . . . . . . 258 Rack-Mount Fan Speed Control . . . . . . . . . . . . . . . . . . . 259 PACKAGED BLOWERS Rack-Mountable Blowers. . . . . . . . . . . . . . . . . . . . . . . . 260 AIR MOVERS Rack-Mountable Fan Package . . . . . . . . . . . . . . . . . . . . 266 Exhaust Grilles and Replacement Filters. . . . . . . . . . . . 267 Filter Box Fans. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268 BLOWERS Centrifugal Blowers. . . . . . . . . . . . . . . . . . . . . . . . . . . . 270 MOTORIZED IMPELLERS AC Motorized Impellers. . . . . . . . . . . . . . . . . . . . . . . . . . 274 DC Motorized Impellers. . . . . . . . . . . . . . . . . . . . . . . . . .282 ACCESSORIES FAN TRAYS Fan Trays deliver a versatile solution to efficiently cool card cages and racks. Redundant cooling with optional failure detection ensures reliable cooling for sensitive electronic equipment. With a slim, field-adjustable design, these 19-inch rack mountable trays provide simple installation and easy access. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Filter Grille Panel. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Louver Plate Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Louver Plate Kit Filters. . . . . . . . . . . . . . . . . . . . . . . . . . Vent Kit. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ventilator. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Filter Adhesive. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cooling 290 291 291 292 292 293 205 4 4 Fresh Air Enclosure Cooling Direct Air Cooling Systems (DACS) DACS OUTDOOR DIRECT AIR COOLING SYSTEMS (DACS) INDUSTRY STANDARDS OPTIONS • • • • UL Recognized CE Telcordia GR-487 capable ustom Material: Aluminum, Stainless Steel, Mild Steel C Custom Finish: Paint Color Custom Power Input: 24 VDC, 115 VAC, & 230 VAC Custom Sizes: Height 29 in. (737 mm) to 56 in. (1422 mm) APPLICATION • • • • • Outdoor telecommunications equipment Industrial automation Outdoor kiosk Outdoor displays OSP applications FEATURES • • • • • • • • • • • • • • ustomizable solutions to meet any customer need C Two models utilizing Hydrophobic GORE® filter Two models with MERV 12, pleated filter Standard power input: 48 VDC UL Listed to save time and money with agency approvals Power Cord included E asy to replace filters Broad operating temperature range -40 C to 55 C Every unit functionally tested before shipping H ydrophobic GORE® filter protects against salt and other corrosive agents Controller provides soft start and current limiting at start up V ibration resistant to withstand over-the-ground transportation of the telecom system Variable speed blowers standard on units for quiet running Controller provides fan speed control and temperature alarm FINISH • tandard Finish: Galvanized steel with RAL 7035 light-gray semiS textured powder coat paint 206 Cooling NOTES Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. GORE® is a registered trademark of W.L. Gore & Associates, Inc. SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data DACS CATALOG NUMBERS COOLING PERFORMANCE Nominal: Watts/°F Watts/°C Operating Temperature Range: Maximum (°F/°C) Minimum (°F/°C) Air Flow at 0 Static Pressure: (CFM/ m3/hr.) ELECTRICAL DATA Rated Voltage (VDC) Operating Range (VDC) Max. Power Consumption (Watts) Max. Nominal Current (Amps) Agency Approvals ENCLOSURE PROTECTION UL Type CONTROLLER Description Factory Thermostat Setting (°F/°C) SOUND LEVEL At 1.5 Meters - Full Speed (dBA) UNIT CONSTRUCTION Material Finish Filter Type UNIT DIMENSIONS Height (in./mm) Width (in./mm) Depth (in./mm) Weight (lb./kg) DCG4108548100 DCG2904248100 DCT5615048100 DCT3809448100 85 152 42 75 50 270 94 170 131/55 -40/-40 265/450 131/55 -40/-40 130/221 131/55 -40/-40 470/799 131/55 -40/-40 300/510 192 4.0 173 3.6 159 3.3 159 3.3 48 40-60 cUL Listed, CE Type 3R Fan speed control and temperature alarm 104/40 67.1 68.1 65.0 63.4 Galvanized Steel RAL 7035 light-gray, semi-textured powder-coat paint standard Pleated Filter Merv 12 Hydrophobic GORE® 40.75/1035 15/381 7.88/200 50/22.7 28.75/730 12/305 7.12/181 40/18.1 56/1422 20/508 7/178 65/29.5 38/965 16/406 6/152 38/17.2 4 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 207 Fresh Air Enclosure Cooling Direct Air Cooling Systems (DACS) '&* 02817,1* *$6.(7)25 02817,1* 72(1&/2685( $0%,(17 $,5287 (1&/2685( $,5287 ),/7(56 $0%,(17 $,5,1 32:(5 $1'$/$50 &211(&7256 (1&/2685( $,5,1 ; 4 Fresh Air Enclosure Cooling Direct Air Cooling Systems (DACS) &87287',0(16,216 208 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION '&* *$6.(7)25 02817,1*72 (1&/2685( $0%,(17 $,5287 $0%,(17 $,5,1 ; (1&/2685( $,5287 ),/7(56 32:(5 $1'$/$50 &211(&7256 (1&/2685( $,5,1 4 ; &87287',0(16,216 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 209 Fresh Air Enclosure Cooling Direct Air Cooling Systems (DACS) '&7 02817,1* *$6.(7)25 02817,1*72 (1&/2685( (1&/2685( $,5287 32:(5 $1'$/$50 &211(&7256 $0%,(17 $,5287 (1&/2685( $,5,1 ),/7(5 $0%,(17 $,5,1 ; 4 Fresh Air Enclosure Cooling Direct Air Cooling Systems (DACS) &87287',0(16,216 210 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION '&7 02817,1* *$6.(7)25 02817,1*72 (1&/2685( 32:(5 $1'$/$50 &211(&7256 (1&/2685( $,5287 $0%,(17 $,5287 (1&/2685( $,5,1 ),/7(5 $0%,(17 $,5,1 4 ; &87287',0(16,216 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 211 Fresh Air Enclosure Cooling Direct Air Cooling Systems (DACS) 4 Fresh Air Enclosure Cooling Filter Fans SF SIDE-MOUNT FILTER FANS SF04 16 CFM (28 m3/hr.) SF13 376 CFM (638 m3/hr.) SF05 39 CFM (66 m3/hr.) SF09 75 CFM (127 m3/hr.) SF13 473 CFM (803 m3/hr.) INDUSTRY STANDARDS • • • • CE, CSA (fan motor only) Type 12, IP54 standard Type 12, IP 55 optional • • • • • • • • • • Industrial automation Automotive assembly Package handling equipment Food and beverage process controlls W ind energy systems Cooling AL 7035 light-gray, UV-resistant plastic standard R R AL 9011 black, UV-resistant plastic optional ACCESSORIES • • • lick-fit design quickly installs into enclosure wall; no tools or C screws required Simple snap-open grille for easy filter replacement Enclosure side wall mounting Reverse airflow option on SF13 models available to push/pull air through higher static pressure Standard foam-in-place gasket Similar cut-out sizes as other filter fan manufacturers Terminal wire connections Optional thermostat available to save energy and extend service life 212 ize rage from 4 in. (102 mm) to 13 in. (325 mm) S Free air flow from 16 CFM (28 m 3 /hr.) to 571 CFM (920 m 3 /hr.) S ervice life hours from 40000 to 70000 hours Operating temperature range fo -4 F/-20 C to 149 F/65 C FINISH APPLICATION FEATURES SF13 571 CFM (970 m3/hr.) SPECIFICATIONS UL/cUL recognized; File No. 235470 • • • • • SF10 162 CFM (275 m3/hr.) Replacement filters Thermostat Rain shroud NOTES Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data SF04 16 CFM (28 m3/hr.) Side-Mount Filter Fan ELECTRICAL DATA Rated Voltage Frequency (Hz) Nominal Current Maximum (Amps) Power Consumption Maximum (Watts) Power Connection TYPE 12 / IP54 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) FILTER FAN UNIT CONSTRUCTION Fan RPM Sound Pressure (dBA) Operating Temperature Range: Maximum (°F / °C) Minimum (°F / °C) Service Life (hours) Unit Dimensions - H x W x D (in. / mm) Cutout Dimensions - H x W (in. / mm) Weight (lb. / kg) TYPE 12 / IP54 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number ACCESSORIES Replacement Filters: Type 12 / IP54 Catalog Number Thermostat Catalog Number 115 50 / 60 1.40/1.20 12 / 11 230 50 / 60 0.70 12 24 — 1.00 2.2 48 — 0.54 2.6 SF0416414 SF0426414 SF0424414 SF0448414 SF0416413 16 / 28 10/17 12/21 SF0426413 16 / 28 10/17 12 / 21 SF0424413 16 / 28 10/17 12 / 21 SF0448413 16 / 28 10/17 12 / 21 2700 / 3200 30 2700 / 3200 30 3300 36 3300 36 131 / 55 14 / -10 37,500 Lead Wires 131 / 55 149 / 65 14 / -10 -4 / -20 37,500 70,000 4.13 x 4.13 x 2.17 / 105 x 105 x 55 3.62 x 3.62 / 92 x 92 .73 / .33 149 / 65 -4 / -20 70,000 SG0400404 SG0400403 10100059H TWR60 Above airflow rates at 60 Hz; see performance curves for airflow at 50 Hz and more details. Unit depth is from the back edge of the grille to the back of the fan. Exhaust Grilles sold separately. 4 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 213 Fresh Air Enclosure Cooling Filter Fans SF04 16 CFM (28 m3/hr.) Side-Mount Filter Fan Performance Curve Volume Flow (CFM) 0 3 6 9 15 12 17 40 .16 35 .14 30 .12 60 IP 50 54 Hz IP 20 .08 54 Static Pressure (Pa) .10 Hz 04 SF 25 0 SG 4 P5 4I 15 .06 10 Static Pressure (in. H2O) 04 SF 4 Fresh Air Enclosure Cooling Filter Fans .04 2x 5 4 SG0 4 IP 5 .02 0 0 0 5 10 15 20 25 30 Volume Flow (m³/hr.) 214 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION )LOWHU)DQ6)&)0PuKU ; ; %$&.9,(: (;+$867*5,//( 6,'(9,(: ; &87287',0(16,216 4 2UGHU([KDXVW*ULOOH.LWVVHSDUDWHO\ Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 215 Fresh Air Enclosure Cooling Filter Fans 4 Fresh Air Enclosure Cooling Filter Fans Performance Data SF05 39 CFM (66 m3/hr.) Side-Mount Filter Fan ELECTRICAL DATA Rated Voltage Frequency (Hz) Nominal Current Maximum (Amps) Power Consumption Maximum (Watts) Power Connection TYPE 12 / IP54 FILTER FANSRAL 7035 Light Gray: RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) TYPE 12 / IP55 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) FILTER FAN UNIT CONSTRUCTION Fan RPM Sound Pressure (dBA) Operating Temperature Range: Maximum (°F / °C) Minimum (°F / °C) Service Life (hours) Unit Dimensions - H x W x D (in. / mm) Cutout Dimensions - H x W (in. / mm) Weight (lb. / kg) TYPE 12 / IP54 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number TYPE 12 / IP55 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number ACCESSORIES Replacement Filters: Type 12 / IP54 Catalog Number Type 12 / IP55 Catalog Number Thermostat Catalog Number Stainless Steel Washdown Shroud Catalog Number 115 50 / 60 0.23 20 230 50 / 60 0.11 20 24 — 0.17 4.1 48 — 0.08 3.5 SF0516414 SF0526414 SF0524414 SF0548414 SF0516413 39 / 66 26 / 44 30 / 51 SF0526413 39 / 66 26 / 44 30 / 51 SF0524413 39 / 66 26 / 44 30 / 51 SF0548413 39 / 66 26 / 44 30 / 51 SF0516514 SF0526514 SF0524514 SF0548514 SF0516513 36 / 61 24 / 40 28 / 47 SF0526513 36 / 61 24 / 40 28 / 47 SF0524513 36 / 61 24 / 40 28 / 47 SF0548513 36 / 61 24 / 40 28 / 47 2650 / 3100 42 2650 / 3100 42 3050 42 3050 42 131 / 55 14 / -10 27,500 Terminal Block 131 / 55 149 / 65 14 / -10 -4 / -20 27,500 50,000 5.83 x 5.83 x 2.56 / 148 x 148 x 65 4.92 x 4.92 / 125 x 125 1.19 / .54 149 / 65 -4 / -20 50,000 SG0500404 SG0500403 SG0500504 SG0500503 10100060 10100064H TWR60 SH0500005 Above airflow rates at 60 Hz; see performance curves for airflow at 50 Hz and more details. Unit depth is from the back edge of the grille to the back of the fan. Exhaust Grilles sold separately. 216 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION SF05 39 CFM (66 m3/hr.) Side-Mount Filter Fan Performance Curve 35 41 .28 .24 SF 05 40 .20 SF 05 50 Hz 60 Hz IP 30 IP 54 .16 54 P 5I .12 54 0 SG 20 2 10 0 10 20 50 30 40 Volume Flow (m³/hr.) 05 x SG 60 4 IP 5 .08 05 40 .20 SF SF 05 50 Hz 30 60 IP Hz 55 IP 10 0 0 .16 55 .12 5 P5 I 05 SG 20 .04 70 41 .28 .24 50 Static Pressure (Pa) Static Pressure (Pa) 50 35 60 Static Pressure (in. H2O) 60 0 TYPE 12 / IP 55 Filter Fan Volume Flow (CFM) 29 0 6 12 18 24 70 P 55 2x 0 10 20 50 30 40 Volume Flow (m³/hr.) Static Pressure (in. H2O) TYPE 12 / IP 54 Filter Fan Volume Flow (CFM) 29 0 6 12 18 24 70 5I SG0 60 .08 .04 70 0 ),/7(5)$1 ; 4 %$&.9,(: (;+$867*5,//( 6,'(9,(: &87287 Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 217 Fresh Air Enclosure Cooling Filter Fans 4 Fresh Air Enclosure Cooling Filter Fans Performance Data SF09 75 CFM (127 m3/hr.) Side-Mount Filter Fan ELECTRICAL DATA Rated Voltage Frequency (Hz) Nominal Current Maximum (Amps) Power Consumption Maximum (Watts) Power Connection TYPE 12 / IP54 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) TYPE 12 / IP55 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) FILTER FAN UNIT CONSTRUCTION Fan RPM Sound Pressure (dBA) Operating Temperature Range: Maximum (°F / °C) Minimum (°F / °C) Service Life (hours) Unit Dimensions - H x W x D (in. / mm) Cutout Dimensions - H x W (in. / mm) Weight (lb. / kg) TYPE 12 / IP54 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number TYPE 12 / IP55 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number ACCESSORIES Replacement Filters: Type 12 / IP54 Catalog Number Type 12 / IP55 Catalog Number Thermostat Catalog Number Stainless Steel Washdown Shroud Catalog Number 115 50 / 60 0.23 20 230 50 / 60 0.11 20 24 — 0.17 4.1 48 — 0.08 3.5 SF0916414 SF0926414 SF0924414 SF0948414 SF0916413 75 / 127 59 / 100 67 / 114 SF0926413 75 / 127 59 / 100 67 / 114 SF0924413 75 / 127 59 / 100 67 / 114 SF0948413 75 / 127 59 / 100 67 / 114 SF0916514 SF0926514 SF0924514 SF0948514 SF0916513 70 / 118 54 / 92 62 / 106 SF0926513 70 / 118 54 / 92 62 / 106 SF0924513 70 / 118 54 / 92 62 / 106 SF0948513 70 / 118 54 / 92 62 / 106 2650 / 3100 51 2650 / 3100 51 3050 51 3050 51 131 / 55 14 / -10 27,500 Terminal Block 131 / 55 149 / 65 14 / -10 -4 / -20 27,500 50,000 8.03 x 8.03 x 3.54 / 204 x 204 x 90 6.97 x 6.97 / 177 x 177 1.74 / .79 149 / 65 -4 / -20 50,000 SG0900404 SG0900403 SG0900504 SG0900503 10100061 10100065H TWR60 SH0900005 Above airflow rates at 60 Hz; see performance curves for airflow at 50 Hz and more details. Unit depth is from the back edge of the grille to the back of the fan. Exhaust Grilles sold separately. 218 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION SF09 75 CFM (127 m3/hr.) Side-Mount Filter Fan Performance Curve .20 +] ,3 20 6* [ 10 0 20 100 40 60 80 Volume Flow (m³/hr.) ,3 120 .12 40 .20 +] ,3 .16 30 .08 20 .04 10 0 0 140 30 .16 6* 50 ,3 ] ,3 + +] .24 6) 40 60 .28 Static Pressure (Pa) 6) 50 Static Pressure (in. H2O) .24 6) ,3 60 0 70 .28 6) Static Pressure (Pa) 70 82 .32 71 6* [ 0 20 .12 40 100 60 80 Volume Flow (m³/hr.) ,3 Static Pressure (in. H2O) 82 .32 ,3 71 TYPE 12 / IP 55 Filter Fan Volume Flow (CFM) 59 0 12 24 35 47 80 6* TYPE 12 / IP 54 Filter Fan Volume Flow (CFM) 59 0 12 24 35 47 80 .08 .04 120 0 140 )LOWHU)DQ6)&)0PuKU ; 4 %$&.9,(: (;+$867*5,//( &87287',0(16,216 6,'(9,(: 2UGHU([KDXVW*ULOOH.LWVVHSDUDWHO\ Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 219 Fresh Air Enclosure Cooling Filter Fans 4 Fresh Air Enclosure Cooling Filter Fans Performance Data SF10 162 CFM (275 m3/Hr.) Side-Mount Filter Fan ELECTRICAL DATA Rated Voltage Frequency (Hz) Nominal Current Maximum (Amps) Power Consumption Maximum (Watts) Power Connection TYPE 12 / IP54 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) TYPE 12 / IP55 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) FILTER FAN UNIT CONSTRUCTION Fan RPM Sound Pressure (dBA) Operating Temperature Range: Maximum (°F / °C) Minimum (°F / °C) Service Life (hours) Unit Dimensions - H x W x D (in. / mm) Cutout Dimensions - H x W (in. / mm) Weight (lb. / kg) TYPE 12 / IP54 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number TYPE 12 / IP55 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number ACCESSORIES Replacement Filters: Type 12 / IP54 Catalog Number Type 12 / IP55 Catalog Number Thermostat Catalog Number Stainless Steel Washdown Shroud Catalog Number 115 50 / 60 .53 / .50 43 / 40 230 24 50 / 60 — .30 / .25 0.66 45 / 39 16 Terminal Block 48 — 0.33 16 SF1016414 SF1026414 SF1024414 SF1048414 SF1016413 162 / 275 133 / 226 149 / 253 SF1026413 162 / 275 133 / 226 149 / 253 SF1024413 162 / 275 133 / 226 149 / 253 SF1048413 162 / 275 133 / 226 149 / 253 SF1016514 SF1026514 SF1024514 SF1048514 SF1016513 149 / 253 122 / 207 137 / 233 SF1026513 149 / 253 122 / 207 137 / 233 SF1024513 149 / 253 122 / 207 137 / 233 SF1048513 149 / 253 122 / 207 137 / 233 2760 / 3030 52 2760 / 3030 52 2950 52 2950 52 131 / 55 14 / -10 40,000 131 / 55 131 / 55 14 / -10 14 / -10 40,000 40,000 9.84 x 9.84 x 4.72 / 250 x 250 x 120 8.78 x 8.78 / 223 x 223 4.19 / 1.9 131 / 55 14 / -10 40,000 SG1000404 SG1000403 SG1000504 SG1000503 10100062 10100066H TWR60 SH1000005 Above airflow rates at 60 Hz; see performance curves for airflow at 50 Hz and more details. Unit depth is from the back edge of the grille to the back of the fan. Exhaust Grilles sold separately. 220 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION SF10 162 CFM (275 m3/hr.) Side-Mount Filter Fan Performance Curve TYPE 12 / IP 54 Filter Fan 47 Volume Flow (CFM) 118 71 94 TYPE 12 / IP 55 Filter Fan 141 165 0 24 47 Volume Flow (CFM) 118 71 94 141 165 120 .48 120 .48 .40 100 ,3 ,3 + ] +] 6) 80 .32 60 .24 40 .16 ,3 6* 20 .08 ,3 [6* 0 0 40 80 200 120 160 Volume Flow (m³/hr.) Static Pressure (Pa) .56 Static Pressure (in. H2O) 140 240 ,3 +] ,3 +] 6) 6) .56 6) 140 100 Static Pressure (Pa) 24 80 60 .40 .32 .24 40 .16 .08 ,3 [6* 0 0 40 80 200 120 160 Volume Flow (m³/hr.) )LOWHU)DQ6)&)0PuKU ,3 6* 20 0 280 Static Pressure (in. H2O) 0 240 0 280 4 %$&.9,(: (;+$867*5,//( 2UGHU([KDXVW*ULOOH.LWVHSDUDWHO\ 6,'(9,(: ; &87287',0(16,216 Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 221 Fresh Air Enclosure Cooling Filter Fans 4 Fresh Air Enclosure Cooling Filter Fans Performance Data SF13 376 CFM (638 m3/hr.) Side-Mount Filter Fan - Standard and Reverse ELECTRICAL DATA Rated Voltage Frequency (Hz) Nominal Current Maximum (Amps) Power Consumption Maximum (Watts) Power Connection TYPE 12 / IP54 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) TYPE 12 / IP55 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) FILTER FAN UNIT CONSTRUCTION Fan RPM Sound Pressure (dBA) Operating Temperature Range: Maximum (°F / °C) Minimum (°F / °C) Service Life (hours) Unit Dimensions - H x W x D (in. / mm) Cutout Dimensions - H x W (in. / mm) Weight (lb. / kg) TYPE 12 / IP54 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number TYPE 12 / IP55 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number ACCESSORIES Replacement Filters: Type 12 / IP54 Catalog Number Type 12 / IP55 Catalog Number Thermostat Catalog Number Stainless Steel Washdown Shroud Catalog Number 115 50 / 60 .58 / .70 64 / 80 230 50 / 60 .29 / .35 64 / 80 24 48 — — 2.60 1.30 55 55 Terminal Block 115 Rvrs 50 / 60 .58 / .70 64 / 80 230 Rvrs 50 / 60 .29 / .35 64 / 80 SF1316414 SF1326414 SF1324414 SF1348414 SF1316414R SF1326414R SF1316413 375 / 638 249 / 423 333 / 565 SF1326413 375 / 638 249 / 423 333 / 565 SF1324413 375 / 638 249 / 423 333 / 565 SF1348413 375 / 638 249 / 423 333 / 565 SF1316413R 375 / 638 249 / 423 333 / 565 SF1326413R 375 / 638 249 / 423 333 / 565 SF1316514 SF1326514 SF1324514 SF1348514 — — SF1316513 346 / 587 228 / 387 301 / 511 SF1326513 346 / 587 228 / 387 301 / 511 SF1324513 346 / 587 228 / 387 301 / 511 SF1348513 346 / 587 228 / 387 301 / 511 — — — — — — — — 2550 / 2800 60 2550 / 2800 60 2950 60 2950 60 2550 / 2800 60 2550 / 2800 60 131 / 55 14 / -10 40,000 131 / 55 14 / -10 40,000 140 / 60 140 / 60 131 / 55 -13 / -25 -13 / -25 14 / -10 40,000 40,000 40,000 12.72 x 12.72 x 5.83 / 323 x 323 x 148 11.5 x 11.5 / 292 x 292 7.5 / 3.4 131 / 55 14 / -10 40,000 SG1300404 SG1300403 SG1300504 SG1300503 10100063 10100067H TWR60 SH1300005 Above airflow rates at 60 Hz; see performance curves for airflow at 50 Hz and more details. Unit depth is from the back edge of the grille to the back of the fan. Exhaust Grilles sold separately. 222 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION SF13 376 CFM (638 m3/hr.) Side-Mount Filter Fan Performance Curve TYPE 12 / IP 54 Filter Fan 294 294 180 180 412 .72 160 .64 160 .64 140 .56 140 .56 .48 120 118 353 200 500 300 400 Volume Flow (m³/hr.) Static Pressure (Pa) .08 20 600 ,3 * 6 .24 .16 0 100 200 .08 ,3 * [6 0 700 .32 60 40 0 3 0 80 .16 * [6 .40 ] , ,3 100 3 ], 20 .48 + 40 .24 * 6 + 6) 60 ,3 Static Pressure (in. H2O) 3 3 ], + ], + .32 100 59 6) .40 80 0 0 6) 6) 100 353 Volume Flow (CFM) 177 235 412 .72 120 Static Pressure (Pa) 59 TYPE 12 / IP 55 Filter Fan Static Pressure (in. H2O) 0 Volume Flow (CFM) 118 177 235 0 500 300 400 Volume Flow (m³/hr.) )LOWHU)DQ6)&)0PuKU 600 700 4 %$&.9,(: (;+$867*5,//( ; 6,'(9,(: &87287',0(16,216 2UGHU([KDXVW*ULOOH.LWVHSDUDWHO\ Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 223 Fresh Air Enclosure Cooling Filter Fans 4 Fresh Air Enclosure Cooling Filter Fans Performance Data SF13 473 CFM (803 m3/hr.) Side-Mount Filter Fan - Standard ELECTRICAL DATA Rated Voltage Frequency (Hz) Nominal Current Maximum (Amps) Power Consumption Maximum (Watts) Power Connection TYPE 12 / IP54 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) TYPE 12 / IP55 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) FILTER FAN UNIT CONSTRUCTION Fan RPM Sound Pressure (dBA) Operating Temperature Range: Maximum (°F / °C) Minimum (°F / °C) Service Life (hours) Unit Dimensions - H x W x D (in. / mm) Cutout Dimensions - H x W (in. / mm) Weight (lb. / kg) TYPE 12 / IP54 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number TYPE 12 / IP55 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number ACCESSORIES Replacement Filters: Type 12 / IP54 Catalog Number Type 12 / IP55 Catalog Number Thermostat Catalog Number Stainless Steel Washdown Shroud Catalog Number 115 50 / 60 1.02 / 1.4 115 / 166 230 50 / 60 .51 / .74 115 / 175 Terminal Block 400 50 / 60 .22 /. 26 110 / 150 SF1316424 SF1326424 SF1340424 SF1316423 473 / 803 343 / 583 399 / 677 SF1326423 473 / 803 343 / 583 399 / 677 SF1340423 473 / 803 343 / 583 399 / 677 SF1316524 SF1326524 SF1340524 SF1316523 436 / 740 314 / 533 369 / 627 SF1326523 436 / 740 314 / 533 369 / 627 SF1340523 436 / 740 314 / 533 369 / 627 2450 / 2650 70 2550 / 2750 70 2650 / 2900 70 131 / 55 14 / -10 40,000 131 / 55 14 / -10 40,000 12.72 x 12.72 x 6.38 / 323 x 323 x 162 11.50 x 11.50 / 292 x 292 7.72 / 3.5 131 / 55 14 / -10 40,000 SG1300404 SG1300403 SG1300504 SG1300503 10100063 10100067H TWR60 SH1300005 Above airflow rates at 60 Hz; see performance curves for airflow at 50 Hz and more details. Unit depth is from the back edge of the grille to the back of the fan. Exhaust Grilles sold separately. 224 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION SF13 473 CFM (803 m3/hr.) Side-Mount Filter Fan Performance Curve TYPE 12 / IP 54 Filter Fan TYPE 12 / IP 55 Filter Fan 59 118 177 235 294 353 Volume Flow (CFM) 412 471 530 589 0 59 118 177 235 294 353 412 471 530 589 225 .90 200 .80 200 .80 175 .70 175 .70 100 200 300 400 500 600 700 800 0 25 0 ,3 [ ,3 50 +] .30 100 .40 75 .20 50 .10 25 0 900 1000 .50 ,3 6* ,3 6* +] 75 .40 125 .60 100 .50 150 ,3 +] ,3 +] ,3 * 6 6) 125 .60 6) 6) 150 Static Pressure (Pa) .90 Static Pressure (in. H2O) 225 6) Static Pressure (Pa) 0 ,3 * [6 .30 .20 .10 0 0 Volume Flow (m³/hr.) Static Pressure (in. H2O) Volume Flow (CFM) 100 200 300 400 500 600 700 800 0 900 1000 Volume Flow (m³/hr.) )LOWHU)DQ6)&)0PuKU 5 4 %$&.9,(: (;+$867*5,//( 6,'(9,(: ; &87287',0(16,216 2UGHU([KDXVW*ULOOH.LWVHSDUDWHO\ Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 225 Fresh Air Enclosure Cooling Filter Fans 4 Fresh Air Enclosure Cooling Filter Fans Performance Data SF13 473 CFM (803 m3/hr.) Side-Mount Filter Fan - Reverse ELECTRICAL DATA Rated Voltage Frequency (Hz) Nominal Current Maximum (Amps) Power Consumption Maximum (Watts) Power Connection TYPE 12 / IP54 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) FILTER FAN UNIT CONSTRUCTION Fan RPM Sound Pressure (dBA) Operating Temperature Range: Maximum (°F / °C) Minimum (°F / °C) Service Life (hours) Unit Dimensions - H x W x D (in. / mm) Cutout Dimensions - H x W (in. / mm) Weight (lb. / kg) TYPE 12 / IP54 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number TYPE 12 / IP55 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number ACCESSORIES Replacement Filters: Type 12/IP54 Catalog Number Type 12 / IP55 Catalog Number Thermostat Catalog Number Stainless Steel Washdown Shroud Catalog Number 115 Rvrs 50 / 60 1.05 / 1.5 120 / 175 230 Rvrs 50 / 60 .51 / .70 115 / 165 Terminal Block 400 Rvrs 50 / 60 .22 / .26 110 /1 50 SF1316424R SF1326424R SF1340424R SF1316423R 473 / 803 343 / 583 399 / 677 SF1326423R 473 / 803 343 / 583 399 / 677 SF1340423R 473 / 803 343 / 583 399 / 677 2450 / 2650 70 2550 / 2750 70 2650 / 2900 70 131 / 55 14 / -10 40,000 131 / 55 14 / -10 40,000 12.72 x 12.72 x 6.38 / 323 x 323 x 162) 11.50 x 11.50 / 292 x 292) 7.72 / 3.5 131 / 55 14 / -10 40,000 SG1300404 SG1300403 SG1300504 SG1300503 10100063 10100067H TWR60 SH1300005 Above airflow rates at 60 Hz; see performance curves for airflow at 50 Hz and more details. Unit depth is from the back edge of the grille to the back of the fan. Exhaust Grilles sold separately. 226 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data SF13 571 CFM (970 m3/hr.) Side-Mount Filter Fan - Standard ELECTRICAL DATA Rated Voltage Frequency (Hz) Nominal Current Maximum (Amps) Power Consumption Maximum (Watts) Power Connection TYPE 12 / IP54 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) TYPE 12 / IP55 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) FILTER FAN UNIT CONSTRUCTION Fan RPM Sound Pressure (dBA) Operating Temperature Range: Maximum (°F / °C) Minimum (°F / °C) Service Life (hours) Unit Dimensions - H x W x D (in. / mm) Cutout Dimensions - H x W (in. / mm) Weight (lb. / kg) TYPE 12 / IP54 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number TYPE 12 / IP55 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number ACCESSORIES Replacement Filters: Type 12 / IP54 Catalog Number Type 12 / IP55 Catalog Number Thermostat Catalog Number Stainless Steel Washdown Shroud Catalog Number 115 50 / 60 1.02 / 1.47 115 / 175 230 50 / 60 .6 / .92 135 / 215 24 — 5.00 105 Terminal Block 48 — 2.60 105 400/460 50 / 60 .25 / .27 113 / 172 SF1316434 SF1326434 SF1324434 SF1348434 SF1346434 SF1316433 571 / 970 377 / 640 454 / 770 SF1326433 571 / 970 377 / 640 454 / 770 SF1324433 571 / 970 377 / 640 454 / 770 SF1348433 571 / 970 377 / 640 454 / 770 SF1346433 571 / 970 377 / 640 454 / 770 SF1316534 SF1326534 SF1324534 SF1348534 SF1346534 SF1316533 526 / 893 345 / 586 415 / 705 SF1326533 526 / 893 345 / 586 415 / 705 SF1324533 526 / 893 345 / 586 415 / 705 SF1348533 526 / 893 345 / 586 415 / 705 SF1346533 526 / 893 345 / 586 415 / 705 2600 / 2850 70 2650 / 2950 69 2750 70 2750 70 2650 / 3050 73 140 / 60 5 / -15 40,000 140 / 60 140 / 60 140 / 60 5 / -15 5 / -15 5 / -15 40,000 40,000 40,000 12.72 x 12.72 x 5.51 / 323 x 323 x 140 11.50 x 11.50 / 292 x 292 10.14 / 4.6 140 / 60 5 / -15 40,000 SG1300404 SG1300403 SG1300504 SG1300503 4 1010063 10100067H TWR60 SH1300005 Unit depth is from the back edge of the grille to the back of the fan. Exhaust Grilles sold separately. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 227 Fresh Air Enclosure Cooling Filter Fans SF13 571 CFM (970 m3/hr.) Side-Mount Filter Fan Performance Curve 200 .80 200 .80 .70 175 .70 .60 .50 * ,3 125 .40 [ 6 100 .30 75 50 ,3 6* [ 25 0 0 100 200 300 400 500 600 700 800 150 125 .60 100 50 .10 25 .50 .40 75 .20 0 900 1000 ,3 ,3 ,3 471 ] ] ] + + 177 + ,3 Static Pressure (Pa) 530 589 .90 6) 150 225 +] 175 118 6) 6) 59 ,3 225 0 Volume Flow (CFM) 235 294 353 412 530 589 .90 471 [ 6* 118 Static Pressure (Pa) 59 TYPE 12 / IP 55 Filter Fan Static Pressure (in. H2O) 0 Volume Flow (CFM) 177 235 294 353 412 6* [ ,3 .30 Static Pressure (in. H2O) TYPE 12 / IP 54 Filter Fan 6) 4 Fresh Air Enclosure Cooling Filter Fans .20 .10 0 0 Volume Flow (m³/hr.) 100 200 300 400 500 600 700 800 0 900 1000 Volume Flow (m³/hr.) )LOWHU)DQ6)&)0PuKU %$&.9,(: (;+$867*5,//( 2UGHU([KDXVW*ULOOH.LWVVHSDUDWHO\ 6,'(9,(: ; &87287',0(16,216 Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. 228 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data SF13 571 CFM (970 m3/hr.) Side-Mount Filter Fan - Reverse ELECTRICAL DATA Rated Voltage Frequency (Hz) Nominal Current Maximum (Amps) Power Consumption Maximum (Watts) Power Connection TYPE 12 / IP54 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) FILTER FAN UNIT CONSTRUCTION Fan RPM Sound Pressure (dBA) Operating Temperature Range: Maximum (°F / °C) Minimum (°F / °C) Service Life (hours) Unit Dimensions - H x W x D (in. / mm) Cutout Dimensions - H x W (in. / mm) Weight (lb. / kg) TYPE 12 / IP54 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number TYPE 12 / IP55 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number ACCESSORIES Replacement Filters: Type 12 / IP54 Catalog Number Type 12 / IP55 Catalog Number Thermostat Catalog Number Stainless Steel Washdown Shroud Catalog Number 115 50 / 60 1.02 / 1.47 115 / 175 230 50 / 60 .6 / .92 135 / 215 Terminal Block 400/460 50 / 60 .25 / .27 113 / 160 SF1316434R SF1326434R SF1340434R SF1316433R 571 / 970 377 / 640 454 / 770 SF1326433R 571 / 970 377 / 640 454 / 770 SF1346433R 571 / 970 377 / 640 454 / 770 2600 / 2850 70 2650 / 2950 69 2650 / 3050 73 140 / 60 5 / -15 40,000 140 / 60 5 / -15 40,000 12.72 x 12.72 x 5.51 / 323 x 323 x 140 11.50 x 11.50 / 292 x 292 10.14 / 4.6 140 / 60 5 / -15 40,000 SG1300404 SG1300403 SG1300504 SG1300503 10100063 10100067H TWR60 SH1300005 Above airflow rates at 60 Hz; see performance curves for airflow at 50 Hz and more details. Unit depth is from the back edge of the grille to the back of the fan. 4 Exhaust Grilles sold separately. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 229 Fresh Air Enclosure Cooling Filter Fans 4 Fresh Air Enclosure Cooling Filter Fans ST THIN SIDE-MOUNT ST10 100 CFM (170 m3/hr.) INDUSTRY STANDARDS • • • UL/cUL recognized; File no. 235470 CE, CSA (fan motor only) Type 12, IP54 standard Type 12, IP55 optional • • • Industrial automation Automotive assembly Package handling equipment Food and beverage process controlls W ind energy systems FEATURES • • • • • • Cooling ree airflow from 100 CFM (170 m 3 /hr.) to 303 CFM (515 m 3 /hr.) F S ervice life hours range from 40000 to 57500 Operating temperature range of -4 F / -20 C to 149 F / 65 C FINISH • • AL 7035 light-gray UV-resistant plastic standard R R AL 9011 black UV-resistant plastic optional ACCESSORIES T13 has reverse airflow option available to push/pull air through S higher static pressure Click-fit design quickly installs into enclosure wall; no tools or screws required Thin depth to minimize cabinet intrusion Enclosure side wall mounting Standard foam-in-place gasket Similar cut-out sizes as other filter fan manufacturers 230 erminal wire connections T Simple snap-open grille for easy filter replacement Optional thermostat available to save energy and extend service life SPECIFICATIONS APPLICATION • • • • • ST13 303 CFM (515 m3/hr.) • • • Replacement filters Thermostat Rain shroud NOTES Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data ST10 100 CFM (170 m3/hr.) Thin Side-Mount Filter Fan ELECTRICAL DATA Rated Voltage Frequency (Hz) Nominal Current Maximum (Amps) Power Consumption Maximum (Watts) Power Connection TYPE 12 / IP54 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) TYPE 12 / IP55 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) FILTER FAN UNIT CONSTRUCTION Fan RPM Sound Pressure (dBA) Operating Temperature Range: Maximum (°F / °C) Minimum (°F / °C) Service Life (hours) Unit Dimensions - H x W x D (in. / mm) Cutout Dimensions - H x W (in. / mm) Weight (lb. / kg) TYPE 12 / IP54 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number TYPE 12 / IP55 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number ACCESSORIES Replacement Filters: Type 12 / IP54 Catalog Number Type 12 / IP55 Catalog Number Thermostat Catalog Number Stainless Steel Washdown Shroud Catalog Number 115 50 / 60 0.2 18 230 50 / 60 0.10 18 24 — 0.27 6.5 48 — 0.14 6.5 ST1016414 ST1026414 ST1024414 ST1048414 ST1016413 100 / 170 74 / 125 84 / 143 ST1026413 100 / 170 74 / 125 84 / 143 ST1024413 100 / 170 74 / 125 84 / 143 ST1048413 100 / 170 74 / 125 84 / 143 ST1016514 ST1026514 ST1024514 ST1048514 ST1016513 92 / 156 67 / 114 77 / 130 ST1026513 92 / 156 67 / 114 77 / 130 ST1024513 92 / 156 67 / 114 77 / 130 ST1048513 92 / 156 67 / 114 77 / 130 2750 / 3100 44 2750 / 3100 44 3150 46 3150 46 131 / 55 14 / -10 40,000 Terminal Block 131 / 55 149 / 65 14 / -10 -4 / -20 40,000 57,500 9.84 x 9.84 x 4.02 / 250 x 250 x 102 8.78 x 8.78 / 223 x 223 2.54 / 1.15 149 / 65 -4 / -20 57,500 SG1000404 SG1000403 SG1000504 SG1000503 4 10100062 10100066H TWR60 SH1000005 Above airflow rates at 60 Hz; see performance curves for airflow at 50 Hz and more details. Unit depth is from the back edge of the grille to the back of the fan. Exhaust Grilles sold separately. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 231 Fresh Air Enclosure Cooling Filter Fans 4 Fresh Air Enclosure Cooling Filter Fans ST10 100 CFM (170 m3/hr.) Thin Side-Mount Filter Fan Performance Curve 74 88 70 60 67 Static Pressure (Pa) 50 67 40 +] ,3 ,3 30 103 .28 .24 60 .24 .20 50 .12 20 ,3 6* 10 .08 0 0 25 50 125 75 100 Volume Flow (m³/hr.) 67 40 30 88 .20 +] +] .16 ,3 ,3 .12 20 ,3 .08 6* .04 0 175 ,3 [6* 0 0 150 67 29 10 .04 ,3 [6* 15 74 70 .16 +] 0 Volume Flow (CFM) 44 59 103 .28 Static Pressure (Pa) 15 Static Pressure (In. H2O) 0 Volume Flow (CFM) 44 29 59 Static Pressure (In. H2O) TYPE 12 / IP 55 Filter Fan TYPE 12 / IP 54 Filter Fan 25 50 0 125 75 100 Volume Flow (m³/hr.) 150 175 )LOWHU)DQ67&)0PuKU %$&.9,(: (;+$867*5,//( 6,'(9,(: ; &87287',0(16,216 2UGHU([KDXVW*ULOOH.LWVVHSDUDWHO\ Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. 232 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data ST13 303 CFM (515 m3/hr.) Thin Side-Mount Filter Fan - Standard and Reverse ELECTRICAL DATA Rated Voltage Frequency (Hz) Nominal Current Maximum (Amps) Power Consumption Maximum (Watts) Power Connection TYPE 12 / IP54 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) TYPE 12 / IP55 FILTER FANS RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) FILTER FAN UNIT CONSTRUCTION Fan RPM Sound Pressure (dBA) Operating Temperature Range: Maximum (°F / °C) Minimum (°F / °C) Service Life (hours) Unit Dimensions - H x W x D (in. / mm) Cutout Dimensions - H x W (in. / mm) Weight (lb. / kg) TYPE 12 / IP54 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number TYPE 12 / IP55 EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number RAL 9011 Black: Catalog Number ACCESSORIES Replacement Filters: Type 12 / IP54 Catalog Number Type 12 / IP55 Catalog Number Thermostat Catalog Number Stainless Steel Washdown Shroud Catalog Number 115 50 / 60 .58 / .70 64 / 80 230 50 / 60 .29 / .35 64 / 80 ST1316414 ST1326414 ST1316414R ST1326414R ST1316413 303 / 515 209 / 355 249 / 422 ST1326413 303 / 515 209 / 355 249 / 422 ST1316413R 303 / 515 209 / 355 249 / 422 ST1326413R 303 / 515 209 / 355 249 / 422 ST1316514 ST1326514 ST1316514R ST1326514R ST1316513 277 / 470 191 / 325 219 / 372 ST1326513 277 / 470 191 / 325 219 / 372 ST1316513R 277 / 470 191 / 325 219 / 372 ST1326513R 277 / 470 191 / 325 219 / 372 2550 / 2800 60 2550 / 2800 60 2550 / 2800 60 2550 / 2800 60 131 / 55 14 / -10 40,000 115 50 / 60 .58 / .70 64 / 80 Terminal Block 131 / 55 131 / 55 14 / -10 14 / -10 40,000 40,000 12.72 x 12.72 x 4.8 / 323 x 323 x 122 11.50 x 11.50 / 292 x 292 7.5 / 3.4 230 50 / 60 .29 / .35 64 / 80 131 / 55 14 / -10 40,000 SG1300404 SG1300403 SG1300504 SG1300503 4 10100063 10100067H TWR60 SH1300005 Above airflow rates at 60 Hz; see performance curves for airflow at 50 Hz and more details. Unit depth is from the back edge of the grille to the back of the fan. Exhaust Grilles sold separately. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 233 Fresh Air Enclosure Cooling Filter Fans ST13 303 CFM (515 m3/hr.) Thin Side-Mount Filter Fan Performance Curve TYPE 12 / IP 54 Filter Fan TYPE 12 / IP 55 Filter Fan Volume Flow (CFM) 160 140 .56 140 .56 .48 120 .48 * 60 6 40 200 300 500 400 600 100 .16 3 0 100 .24 , * 6 [ 20 0 .32 ,3 0 59 118 177 235 353 80 412 .64 .40 60 .32 .24 ,3 6* [ ,3 6* 40 .08 294 .16 .08 20 0 700 Static Pressure (in. H2O) .40 Static Pressure (Pa) 353 3 ], + 3 ], + 67 67 Static Pressure (Pa) 235 3 ] , + 3 ], + 67 80 177 Volume Flow (CFM) 160 100 118 294 412 .64 120 59 Static Pressure (in. H2O) 0 67 4 Fresh Air Enclosure Cooling Filter Fans 0 0 0 Volume Flow (m³/hr.) 100 200 300 400 500 600 700 Volume Flow (m³/hr.) )LOWHU)DQ67&)0PuKU %$&.9,(: (;+$867*5,//( 6,'(9,(: ; &87287',0(16,216 2UGHU([KDXVW*ULOOH.LWVHSDUDWHO\ Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. 234 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Notes 4 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 235 Fresh Air Enclosure Cooling Filter Fans 4 Fresh Air Enclosure Cooling Filter Fans SR TOP-MOUNT INDUSTRY STANDARDS FEATURES • • • • UL (fan motor only) CE, CSA (fan motor only) APPLICATION • • • • • ree airflow up to 280 CFM (475 m 3 /hr.) or 459 CFM (780 m 3 /hr.) F Enclosure roof mounting Bolt in place to ensure a tight seal Terminal wire connections FINISH Industrial automation Automotive assembly Package handling equipment Food and beverage process controlls W ind energy systems • • AL 7035 light-gray UV-resistant mild steel standard R R AL 9011 black UV-resistant mild steel optional NOTES Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. Performance Data SR16 280 CFM (475 m3/hr.) Roof-Mount Filter Fan ELECTRICAL DATA Rated Voltage Frequency (Hz) Nominal Current Maximum (Amps) Power Consumption Maximum (Watts) Power Connection FILTER FANS RAL 7035 Light Gray: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) FILTER FAN UNIT CONSTRUCTION Fan RPM Sound Pressure (dBA) Operating Temperature Range: Maximum (°F / °C) Minimum (°F / °C) Service Life (hours) Unit Dimensions - H x W x D (in. / mm) Cutout Dimensions - H x W (in. / mm) Weight (lb. / kg) EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number ACCESSORIES Replacement Filters: Catalog Number Thermostat Catalog Number 115 50 / 60 .35 / .40 40 / 45 Terminal Block 230 50 / 60 .20 / .21 40 / 45 SR1616414 227 / 386 151 / 257 183 / 311 SR1626414 227 / 386 151 / 257 183 / 311 1430 / 1700 58 / 62 1430 / 1700 58 / 62 140 / 60 140 / 60 14 / -10 14 / -10 40,000 40,000 13.52 x 16.27 x 4.19 / 343 x 413 x 107 10.43 x 13.58 / 265 x 345 17.20 / 7.8 SG1300404 10100063 TWR60 Above airflow rates at 60 Hz; see performance curves for airflow at 50 Hz and more details. Unit depth is from the back edge of the grille to the back of the fan. 236 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION SR16 280 CFM (475 m3/hr.) Roof-Mount Filter Fan Performance Curve 44 88 Volume Flow (CFM) 132 177 221 265 309 353 397 441 486 2.71 600 2.41 525 2.11 450 1.81 375 1.51 300 .90 SR16 60 H z 150 SR1 6 50 H z 75 0 1.21 3 SG1 225 0 75 Static Pressure (in. H2O) Static Pressure (Pa) 675 0 3 2 x SG1 .60 .30 150 225 300 375 450 525 600 675 750 825 Volume Flow (m³/hr.) 0 )LOWHU)DQ65&)0PuKU 4 ; &87287',0(16,216 Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 237 Fresh Air Enclosure Cooling Filter Fans 4 Fresh Air Enclosure Cooling Filter Fans Performance Data SR16 459 CFM (780 m3/hr.) Roof-Mount Filter Fan ELECTRICAL DATA Rated Voltage Frequency (Hz) Nominal Current Maximum (Amps) Power Consumption Maximum (Watts) Power Connection FILTER FANS RAL 7035 Light Gray: Catalog Number Free Airflow (CFM / m3/hr.) Airflow with 1 Exhaust Grille (CFM / m3/hr.) Airflow with 2 Exhaust Grilles (CFM / m3/hr.) FILTER FAN UNIT CONSTRUCTION Fan RPM Sound Pressure (dBA) Operating Temperature Range: Maximum (°F / °C) Minimum (°F / °C) Service Life (hours) Unit Dimensions - H x W x D (in. / mm) Cutout Dimensions - H x W (in. / mm) Weight (lb. / kg) EXHAUST GRILLES RAL 7035 Light Gray: Catalog Number ACCESSORIES Replacement Filters: Catalog Number Thermostat Catalog Number 115 50 / 60 .60 / .80 100 / 130 Terminal Block 230 50 / 60 .55 / .73 110 / 150 SR1616424 459 / 780 347 / 590 400 / 680 SR1626424 459 / 780 347 / 590 400 / 680 2650 / 2950 73 / 76 2650 / 2950 73 / 76 140 / 60 140 / 60 14 / -10 14 / -10 40,000 40,000 13.52 x 16.27 x 4.19 / 343 x 413 x 107 10.43 x 13.58 / 265 x 345 17.20 / 7.8 SG1300404 10100063 TWR60 Above airflow rates at 60 Hz; see performance curves for airflow at 50 Hz and more details. Unit depth is from the back edge of the grille to the back of the fan. 238 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION SR16 459 CFM (780 m3/hr.) Roof-Mount Filter Fan Performance Curve 44 Volume Flow (CFM) 132 177 221 265 309 353 397 441 486 2.71 88 600 2.41 Static Pressure (Pa) 525 SR 450 SR1 16 65 375 0H 2.11 60 1.81 Hz z 1.51 300 225 .90 3 2 x SG1 75 0 1.21 3 SG1 150 0 75 Static Pressure (in. H2O) 675 0 .60 .30 150 225 300 375 450 525 600 675 750 825 Volume Flow (m³/hr.) 0 )LOWHU)DQ65&)0PuKU 4 ; &87287',0(16,216 Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 239 Fresh Air Enclosure Cooling Filter Fans 4 Fresh Air Enclosure Cooling Filter Fans FILTER FAN SHROUDS INDUSTRY STANDARDS Maintains UR/cUR Type 3R and Type 12 rating when properly installed on a Type 3R or Type 12 enclosure UL 508A UR/cUR; Type 3R; File No. 61997 FEATURES • • • • • • • rotects filter fan and exhaust grill from wind-driven rain and P high-pressure hose water Does not impede air flow of filter fan and exhaust grill E asy one person installation with simple back panel mounting E asily accessed filter simplifies replacement Low profile design Stainless steel pest screen Provides Type 3R protections and maintains a Type 12 rating when used with an equivalent rated filter kit FINISH • • • AL 7035 light gray polyester powder coat paint on galvanized R metal A NSI 61 gray polyester powder coat paint on galvanized metal Stainless Steel #304 Performance Data SH05 Models Catalog Number Provides protection for: Filter Fan Models Exhaust Grille Models Unit Construction Material Finish Unit Dimensions H x W x D (in./mm) SH09 Models Catalog Number Provides protection for: Filter Fan Models Exhaust Grille Models Unit Construction Material Finish Unit Dimensions H x W x D (in./mm) SH10 Models Catalog Number Provides protection for: Filter Fan Models Exhaust Grille Models Unit Construction Material Finish Unit Dimensions H x W x D (in./mm) SH13 Models Catalog Number Provides protection for: Filter Fan Models Exhaust Grille Models Unit Construction Material Finish Unit Dimensions H x W x D (in./mm) 240 Cooling SH05GS35001 SH05GS61001 SH05SS04001 SF04 and SF05 SG04 and SG05 SF04 and SF05 SG04 and SG05 SF04 and SF05 SG04 and SG05 Glavanized RAL 7035 polyester powder coat paint 10.25 x 8.0 x 2.25/260 x 203 x 57 Glavanized ANSI 61 polyester powder coated paint 10.25 x 8.0 x 2.25/260 x 203 x 57 Stainless Steel #304 N/A 10.25 x 8.0 x 2.25/260 x 203 x 57 SH09GS35001 SH09GS61001 SH09SS04001 SF09 and TFP4 SG09 and TFP4 SF09 and TFP4 SG09 and TFP4 SF09 and TFP4 SG09 and TFP4 Glavanized RAL 7035 polyester powder coat paint 12.75 x 10.0 x 3.0/324 x 254 x 76 Glavanized ANSI 61 polyester powder coated paint 12.75 x 10.0 x 3.0/324 x 254 x 76 Stainless Steel #304 N/A 12.75 x 10.0 x 3.0/324 x 254 x 76 SH10GS35001 SH10GS61001 SH10SS04001 SF10, ST10 and TFP6 SG10 and TFP6 SF10, ST10 and TFP6 SG10 and TFP6 SF10, ST10 and TFP6 SG10 and TFP6 Glavanized RAL 7035 polyester powder coat paint 14.74 x 12.0 x 3.50/374 x 304 x 89 Glavanized ANSI 61 polyester powder coated paint 14.74 x 12.0 x 3.50/374 x 304 x 89 Stainless Steel #304 N/A 14.74 x 12.0 x 3.50/374 x 304 x 89 SH13GS35001 SH13GS61001 SH13SS04001 SF13, ST13 and TFP10 SG13 and TFP10 SF13, ST13 and TFP10 SG13 and TFP10 SF13, ST13 and TFP10 SG13 and TFP10 Glavanized RAL 7035 polyester powder coat paint 17.62 x 16.0 x 4.75/447 x 406 x 121 Glavanized ANSI 61 polyester powder coated paint 17.62 x 16.0 x 4.75/447 x 406 x 121 Stainless Steel #304 N/A SUBJECT TO CHANGE WITHOUT NOTICE 17.62 x 16.0 x 4.75/447 x 406 x 121 EQUIPMENT PROTECTION SF/ST REPLACEMENT FILTERS • • • ype 12 / IP54 filter option provides protection against dust T infiltration (6 filters per package) IP55 filter adds additional protection against moisture S ee individual product pages for catalog and item numbers to order REPLACEMENT FILTER CATALOG NUMBERS 10100059H 10100060 10100064H 10100061 10100065H 10100062 10100066H 10100063 10100067H FITS FAN PACKAGES All SF04 Models All SF05 IP54 Models All SF05 IP55 Models All SF09 IP54 Models All SF09 IP55 Models All SF10 IP54 Models All SF10 IP55 Models All SF13 IP54 Models All SF13 IP55 Models 4 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 241 Fresh Air Enclosure Cooling Filter Fans 4 Fresh Air Enclosure Cooling Filter Fans TFP SIDE-MOUNT TFP10 215 CFM (365 m3/hr.) TFP6 140 CFM (238 m3/hr.) TFP4 55 CFM (93 m3/hr.) INDUSTRY STANDARDS • UL 508A Component Recognized; File No. E61997 TFP# Models: Type 1 TFP# UL 12 Models: Type 12 • CSA certified (fan only) CE • APPLICATION • • • • • • Industrial automation Automotive assembly Package handling equipment Food and beverage process controlls W ind energy systems SPECIFICATIONS • • • FEATURES • • • • • • • ooling Fan Package includes fan, air filter, composite air C plenum, finger guard and grille E xhaust Package includes air filter, filter retainer with integral finger guard and grille EMC Upgrade Kit includes a grille standoff collar and a special EMC shielding grille Reliable cooling for enclosures with limited space requiring simple filtered airflow for basic cooling 24 VDC, 115 VAC and 230 VAC options available Washable foam (Type 1) or disposable (Type 12) filter in fan D ynamically-balanced fan impellers molded from polycarbonate material 242 Cooling -in. fan is thermally protected and uses permanently-lubricated 4 ball bearings 6- and 10-in. fans have ball bearing construction and splitcapacitor motors that are thermally protected to avoid premature failure Fans have lead wires for power connection with ends stripped 1/2 in. (12 mm) All mounting hardware and installation instructions are furnished ree airflow from 45 CFM (76 m 3 /hr.) to 215 CFM (365 m 3 /hr.) F Maximum operating temperature 158 F / 70 C Engineered for 50,000 hours of continuous operation without lubrication or service (a monthly maintenance schedule is recommended to ensure optimal cooling performance) FINISH • • tainless steel grilles have brushed finish. S A BS composite grille is black. ACCESSORIES Aluminum Type 1 and Hi-Density Type 12 Filters EMC Upgrade Kit Grille Options: Stainless Steel Black ABS Plastic SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data TFP4 Models ELECTRICAL DATA Rated Voltage Frequency (Hz) Nominal Current Maximum @ 50/60 Hz(Amps) Power Consumption Maximum @ 50/60 Hz (Watts) Power Connection CATALOG NUMBERS Composite Type 1 Catalog Number Stainless Steel Type 1 Catalog Number Composite Type 12 Catalog Number Free Airflow @ 50/60 Hz (CFM)* Free Airflow @ 50/60 Hz (m3/hr.)* UNIT CONSTRUCTION Noise SIL @ 50/60 Hz (dBA) Maximum Operating Temperature (°F/°C) Unit Dimensions - H x W x D (in./mm) Cutout Dimensions - H x W (in./mm) Weight (lb./kg) EXHAUST GRILLE CATALOG NUMBERS Composite Type 1 Catalog Number Stainless Steel Type 1 Catalog Number Composite Type 12 Catalog Number 24 VDC 115 VAC 50/60 .26/.21 17/15 Stripped Leadwires .35 8.4 230 VAC .14/.11 16/14 TFP424 TFP41 TFP42 — TFP41SS TFP42SS — 55 93 TFP41UL12 45/55 76/93 TFP42UL12 45/55 76/93 65 37/41 158/70 6.29 x 7.37 x 2.65/160 x 187 x 67 5.66 x 5.66/144 x 144 4.2/1.90 4.2/1.90 37/41 4.3/1.95 TEP4 TEP4SS TEP4UL12 *CFM with single exhaust grille installed. 7)30RGHOV ; 4 %$&.9,(: 6,'(9,(: 7(3(;+$867*5,//( )$1*5,//( 287/,1( &87287',0(16,216 ([KDXVWJULOOHLQFOXGHGZLWKIDQSDFNDJH EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 243 Fresh Air Enclosure Cooling Filter Fans 4 Fresh Air Enclosure Cooling Filter Fans Performance Data TFP6 Models ELECTRICAL DATA Rated Voltage Frequency (Hz) Nominal Current Maximum @ 50/60 Hz(Amps) Power Consumption Maximum @ 50/60 Hz (Watts) Power Connection CATALOG NUMBERS Composite Type 1 Catalog Number Stainless Steel Type 1 Catalog Number Composite Type 12 Catalog Number Free Airflow @ 50/60 Hz (CFM)* Free Airflow @ 50/60 Hz (m3/hr.)* UNIT CONSTRUCTION Noise SIL @ 50/60 Hz (dBA) Maximum Operating Temperature (°F/°C) Unit Dimensions - H x W x D (in./mm) Cutout Dimensions - H x W (in./mm) Weight (lb./kg) EXHAUST GRILLE CATALOG NUMBERS Composite Type 1 Catalog Number Stainless Steel Type 1 Catalog Number Composite Type 12 Catalog Number 24 VDC 115 VAC 50/60 .45/.36 36/32 Stripped Leadwires .88 21.1 230 VAC .23/.18 39/35 TFP624 TFP61 TFP62 — TFP61SS TFP62SS — 140 238 TFP61UL12 117/140 199/238 TFP62UL12 117/140 199/238 62.5 50/56 158/70 7.80 x 8.87 x 3.75/198 x 225 x 95 7.16 x 7.16/182 x 182 5.3/2.40 5.3/2.40 50/56 5.4/2.45 TEP6 TEP6SS TEP6UL12 *CFM with single exhaust grille installed. 7)30RGHOV ; 6,'(9,(: %$&.9,(: &87287',0(16,216 7(3(;+$867*5,//( )$1*5,//( 287/,1( ([KDXVWJULOOHLQFOXGHGZLWKIDQSDFNDJH 244 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data TFP10 Models ELECTRICAL DATA Rated Voltage Frequency (Hz) Nominal Current Maximum @ 50/60 Hz(Amps) Power Consumption Maximum @ 50/60 Hz (Watts) Power Connection CATALOG NUMBERS Composite Type 1 Catalog Number Stainless Steel Type 1 Catalog Number Composite Type 12 Catalog Number Free Airflow @ 50/60 Hz (CFM)* Free Airflow @ 50/60 Hz (m3/hr.)* UNIT CONSTRUCTION Noise SIL @ 50/60 Hz (dBA) Maximum Operating Temperature (°F/°C) Unit Dimensions - H x W x D (in./mm) Cutout Dimensions - H x W (in./mm) Weight (lb./kg) EXHAUST GRILLE CATALOG NUMBERS Composite Type 1 Catalog Number Stainless Steel Type 1 Catalog Number Composite Type 12 Catalog Number 115 VAC .58/.70 64/80 230 VAC 50/60 Stripped Leadwires .29/.35 64/80 TFP101 TFP102 TFP101SS TFP102SS TFP101UL12 180/215 306/365 TFP102UL12 180/215 306/365 54/61 54/61 167/75 167/75 11.81 x 12.99 x 5.25/300 x 330 x 133 11.16 x 11.16/283 x 283 12.0/2.45 11.4/5.17 TEP10 TEP10SS TEP10UL12 *CFM with single exhaust grille installed. 7)30RGHOV 4 )$1*5,//( 287/,1( 6,'(9,(: %$&.9,(: 7(3(;+$867*5,//( &87287',0(16,216 ([KDXVWJULOOHLQFOXGHGZLWKIDQSDFNDJH EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 245 Fresh Air Enclosure Cooling Filter Fans 4 Fresh Air Enclosure Cooling Filter Fans TFP EXHAUST GRILLES Nominal Fan Size in./mm CATALOG NUMBERS TEP4 Models TEP4 TEP4SS TEP4UL12 TEP6 Models TEP6 TEP6SS TEP6UL12 TEP10 Models TEP10 TEP10SS TEP10UL12 TFP OPTIONAL GRILLES AND REPLACEMENT FILTERS CATALOG NUMBERS 4-inch Fan Models TG4SS TG4B AFLTR4 AFLTR4AL TFLT4UL12 6-inch Fan Models TG6SS TG6B AFLTR6 AFLTR6AL TFLT6UL12 10-inch Fan Models TG10SS TG10B AFLTR10 AFLTR10AL TFLT10UL12 4 4 4 6 6 6 10 10 10 Optional grilles offer the choice of stainless steel or black ABS plastic. These grilles replace the standard RAL 7035 gray composite or stainless steel grilles on both fan and exhaust packages. Standard replacement filters are washable foam (Type 1) or disposable (Type 12). To maintain UL Type 12 rating on the enclosure, UL Type 12 filters must be used on the fan package inlet. Washable aluminum filters are also available. Aluminum filters are compatible with Type 1 systems only. Type 12 air filters are not washable. Description Fits Fan and Exhaust Nominal Size Fits Fan and Exhaust Grill Size (in./mm) Brushed stainless steel grille 4 Black ABS plastic grille 4 Type 1 filter replacement (5/package) Aluminum filter replacement (5/package) Type 12 filter replacement (5/package) 4 4 4 6.29 x 7.31 x .81 160 x 186 x 21 6.29 x 7.37 x .81 160 x 187 x 21 — — — Brushed stainless steel grille 6 Black ABS plastic grille 6 Foam filter replacement (5/package) Aluminum filter replacement (5/package) UL 12 filter replacement (5/package) 6 6 6 Brushed stainless steel grille 10 Black ABS plastic grille 10 Foam filter replacement (5/package) Aluminum filter replacement (5/package) UL 12 filter replacement (5/package)a 10 10 10 7.80 x 8.81 x .75 198 x 224 x 19 7.80 x 8.87 x .49 198 x 225 x 12 — — — 11.81 x 12.92 x .75 300 x 328 x 19 11.81 x 12.99 x .75 300 x 330 x 19 — — — Replacement filter for Type 12 fan package only (models TFF__UL12). For Type 12 exhaust package use replacement filter AFLTRX. Filters fit all fan and exhaust packages according to their size. 246 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION TFP EMC UPGRADE KIT With the addition of this kit, the cooling fan and exhaust packages are upgraded to provide EMC (electromagnetic compatibility) protection. Consult Hoffman for shielding effectiveness (dB attenuation vs. frequency). Separate kits must be installed on both the inlet and outlet. Cooling fan and exhaust package must be ordered separately. EMC upgrade kit will not work with stainless steel grille option. CATALOG NUMBERS 4-inch Fan Models T4EMC 6-inch Fan Models T6EMC 10-inch Fan Models T10EMC Fits Cooling Fan Package Fits Exhaust Grille TFP41/TFP42 TEP4 TFP61/TFP62 TEP6 TFP101/TFP102 TEP10 4 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 247 Fresh Air Enclosure Cooling Filter Fans 4 Fresh Air Enclosure Cooling Filter Fans OUTDOOR FILTER FAN AND EXHAUST PACKAGE INDUSTRY STANDARDS • cURus Type 12; File No. E234324 • NEMA Type 3R IEC/EN60529, IP55 CE FEATURES • SPECIFICATIONS Ball bearing axial fan, service life minimum 50,000 hours at 77 F (25 C) and 65 percent RH • A irflow 11.8 CFM (20 cubic meters/hour) free blowing • High-impact plastic is highly weatherproof and resistant to UV light • Removable F5 filter • L ockable door in hood • Two-sided tape provided • F ilter hood permanently fixed to enclosure from inside • lead wires, 3.94-in. (100-mm) long, with pressure clamps, 14 2 gauge max. (2.5 mm) Synthetic filter material, temperature resistant to 212 F (100 C), self-extinguishing class F1, moisture resistant to 100 percent RH Filter mat: Fine grade F5 to DIN EN779 filtering degree: 98 percent of particles larger than 10 µm (10 microns) • Aluminum fan body, plastic impeller FINISH • Light gray plastic, UL94H-B ACCESSORIES This fan package meets basic requirements for outdoor or indoor applications that require warm air dissipation. Performance Data Outdoor Filter Fan ELECTRICAL DATA Rated Voltage Frequency (Hz) Full Load (Amps) FILTER FAN Catalog Number UNIT CONSTRUCTION External Mounting Depth (in./mm) Internal Mounting Depth (in./mm) Enclosure Cutout (in./mm) EXHAUST GRILLE Catalog Number ACCESSORIES Replacement Filters: Catalog Number Description Filter Size (in./mm) 248 Cooling 120 VAC 60 0.3 AOFF118 2.56/65 2.44/62 4.92 x 4.92 / 125 x 125 AOEFG118 AOFILTER Filter Mat, F5 (3 per package) 4.80 x 4.80 / 122 x 122 SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Outdoor Filter Fan and Exhaust Package 4 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 249 Fresh Air Enclosure Cooling Filter Fans 4 Fresh Air Enclosure Cooling Axial Fans and Accessories COMPACT AXIAL FANS AXIAL FANS AND ACCESSORIES INDUSTRY STANDARDS • UL Component Recognized • CSA certified • APPLICATION Compact Cooling Fans are ideal for applications where enclosure space is limited and quiet, reliable cooling is required. Engineered for 50,000 hours of continuous operation without lubrication or service. Installation Can be installed on any surface of an enclosure. With the addition of accessory fan brackets, Compact Cooling Fans can also be installed in any position inside the enclosure for spot cooling or air circulation. FEATURES • • • aximum operating temperature is 158 F (70 C) M 4-in. fan is thermally protected and uses permanently lubricated ball bearings 6- and 10-in. fans have ball-bearing construction and splitcapacitor motors 250 Cooling • • • plit-capacitor motors are thermally protected to avoid S premature failure D ynamically balanced impellers molded from polycarbonate material One finger guard is furnished (additional finger guards are available) All mounting hardware is provided 240 and 560 CFM fans have ball bearing construction and split capacitor motors Fans have leadwires with ends stripped 1/2-in. (12-mm) or 6-ft. (1.8-m) cord with polarized plug for power connections Fan bracket and additional finger guards must be purchased separately FINISH • Fan housing is black. ACCESSORIES Fan Power Cords Fan Brackets Finger Guards Temperature Control Switch SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Design Data Compact Axial Fans CATALOG NUMBERS A2AXFN24 3-in. Fans A3AXFN A3AXFN24 4-in. Fans A4AXFNGQ A4AXFNPG A4AXFN A4AXFN2 A4AXFN24 6-in. Fans A6AXFNGQ A6AXFNPG A6AXFN A6AXFN2 A6AXFN24 10-in. Fans A10AXFNPG A10AXFN A10AXFN2 Nominal Size 2 Voltage 24 VDC A in./mm — D in./mm 1.97/50 E in./mm .98/25 J in./mm 1.97/50 K in./mm .98/25 L in./mm — M in./mm — 3 3 115 VAC 24 VDC — — 2.81/71 2.81/71 1.40/36 1.40/36 2.81/71 2.81/71 1.40/36 1.40/36 — — — — 4 4 4 4 4 115 VAC 115 VAC 115 VAC 230 VAC 24 VDC 4.62/117 4.62/117 4.62/117 4.62/117 4.62/117 4.12/105 4.12/105 4.12/105 4.12/105 4.12/105 2.06/52 2.06/52 2.06/52 2.06/52 2.06/52 4.12/105 4.12/105 4.12/105 4.12/105 4.12/105 2.06/52 2.06/52 2.06/52 2.06/52 2.06/52 — — — — — — — — — — 6 6 6 6 6 115 VAC 115 VAC 115 VAC 230 VAC 24 VDC 5.88/149 5.88/149 5.88/149 5.88/149 5.88/149 — — — — — — — — — — — — — — — — — — — — 3.19/81 3.19/81 3.19/81 3.19/81 3.19/81 6.38/162 6.38/162 6.38/162 6.38/162 6.38/162 10 10 10 115 VAC 115 VAC 230 VAC 9.00/229 9.00/229 9.00/229 6.88/175 6.88/175 6.88/175 3.44/87 3.44/87 3.44/87 6.88/175 6.88/175 6.88/175 3.44/87 3.44/87 3.44/87 — — — — — — 4 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 251 Fresh Air Enclosure Cooling Axial Fans and Accessories 4 Fresh Air Enclosure Cooling Axial Fans and Accessories Performance Data Compact Axial Fans ELECTRICAL DATA Rated Voltage Frequency (Hz) Power Connection 2 inch Nominal-Size Fans Catalog Number Nominal Current Maximum @50/60 Hz (Amps) Power Consumption Maximum @ 50/60 Hz (Watts) Free Airflow @ 50/60 Hz (CFM)* Free Airflow @ 50/60 Hz (m3/hr.)* Noise SIL @ 50/60 Hz (dBA) Maximum RPM @50/60 Hz (RPM) Fan Size Diameter (in.) Fan Depth (in.) 3 inch Nominal-Size Fans Catalog Number Nominal Current Maximum @50/60 Hz (Amps) Power Consumption Maximum @ 50/60 Hz (Watts) Free Airflow @ 50/60 Hz (CFM)* Free Airflow @ 50/60 Hz (m3/hr.)* Noise SIL @ 50/60 Hz (dBA) Maximum RPM @50/60 Hz (RPM) Fan Size Diameter (in.) Fan Depth (in.) 4 inch Nominal-Size Fans Catalog Number Nominal Current Maximum @50/60 Hz (Amps) Power Consumption Maximum @ 50/60 Hz (Watts) Free Airflow @ 50/60 Hz (CFM)* Free Airflow @ 50/60 Hz (m3/hr.)* Noise SIL @ 50/60 Hz (dBA) Maximum RPM @50/60 Hz (RPM) Fan Size Diameter (in.) Fan Depth (in.) 6 inch Nominal-Size Fans Catalog Number Nominal Current Maximum @50/60 Hz (Amps) Power Consumption Maximum @ 50/60 Hz (Watts) Free Airflow @ 50/60 Hz (CFM)* Free Airflow @ 50/60 Hz (m3/hr.)* Noise SIL @ 50/60 Hz (dBA) Maximum RPM @50/60 Hz (RPM) Fan Size Diameter (in.) Fan Depth (in.) 10 inch Nominal-Size Fans Catalog Number Nominal Current Maximum @50/60 Hz (Amps) Power Consumption Maximum @ 50/60 Hz (Watts) Free Airflow @ 50/60 Hz (CFM)* Free Airflow @ 50/60 Hz (m3/hr.)* Noise SIL @ 50/60 Hz (dBA) Maximum RPM @50/60 Hz (RPM) Fan Size Diameter (in.) Fan Depth (in.) 24 VDC 115 VAC Lead Wires 115 VAC Power Cord 230 VAC Lead Wires 50/60 Lead Wires 115 VAC Power Cord Quiet Fan 50/60 Power Cord 50/60 Lead Wires 50/60 Power Cord 50/60 Lead Wires A2AXFN24 .09 2.16 21.5 36.5 65 4550 2.36 .98 — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — A3AXFN24 .14 3.36 40 68 35 3400 3.15 .98 A3AXFN .09 7 27 46 40 2700 3.15 1.50 — — — — — — — — — — — — — — — — — — — — — — — — — — — A4AXFN24 .35 84 118 200 46.5 3200 4.69 1.52 A4AXFN .26/.21 17/15 85/100 144/170 37/41 2415/2900 4.69 1.52 A4AXFNGQ .09/.08 6/5 46/49 78/83 27/28 1350/1450 4.69 1.52 A4AXFNPG .26/.21 17/15 85/100 144/170 37/41 2415/2900 4.69 1.52 A4AXFN2 .14/.11 16/14 85/100 144/170 37/41 2415/2900 4.69 1.52 A6AXFN24 .88 21.1 280 476 62.5 3750 6.77 2.00 A6AXFN .45/.36 36/32 200/240 340/408 50/56 2670/3200 6.77 1.50 A6AXFNGQ .16/.19 16/18 85/102 144/173 35/38 1400/1650 6.77 1.50 A6AXFNPG .45/.36 36/32 200/240 340/408 50/56 2670/3200 6.77 1.50 A6AXFN2 .23/.18 39/35 200/240 340/408 50/56 2670/3200 6.77 1.50 — — — — — — — — — A10AXFN 1.0/.88 36/36 480/560 816/951 46/49 1350/1650 10.00 3.50 — — — — — — — — — A10AXFNPG 1.0/.88 36/36 480/560 816/951 46/49 1350/1650 10.00 3.50 A10AXFN2 .47/.43 36/36 480/560 816/951 46/49 1350/1650 10.00 3.50 * CFM without exhaust grille 252 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Curves for Compact Axial Fans 4 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 253 Fresh Air Enclosure Cooling Axial Fans and Accessories 4 Fresh Air Enclosure Cooling Axial Fans and Accessories FAN CORDS Used to power Compact Cooling Fans when positive ground of the cabinet case is required. Available with connectors for one or two fans. Five-foot (1.52-meter) cord with grounded three-prong plug. Fits A4AXFNPG, A6AXFNPG, A10AXFNPG, A4AXFNGQ and A10AXFNGQ. CATALOG NUMBERS DESIGN DATA Description FAN CORDS WITH INLINE THERMOSTAT ACORD1 ACORD2 One connector Two connectors Use to power 120 VAC Compact Cooling Fans; replaces existing supplied power cord. Fan cord includes inline thermostat. The cord automatically activates up to two fans. Fan(s) will turn on when the inline thermostat reaches 86F (30C). Fan(s) will run only when temperature is above 86F (30C). Use with 110-120 VAC fans with power cords only. One or two fans can be used with power cord. ELECTRICAL DATA Rated Voltage Maximum Current (Amps) Fan Activation Temperature (°F/°C) CATALOG NUMBERS FAN FILTER AND FINGER GUARD KIT DESIGN DATA Description Fits Cooling ACORD2T Low-density filter kit for 4-in. (102-mm) and 6-in. (152-mm) fans. Can also be used as vent. Filter is removable and can be cleaned and reused. Mounting hardware included. CATALOG NUMBERS 254 110-120 VAC 10 86/30 SUBJECT TO CHANGE WITHOUT NOTICE AFLTR4LD AFLTR6LD Fan Filter and Finger Guard Kit 4-in. fans 6-in. fans EQUIPMENT PROTECTION FAN BRACKETS CATALOG NUMBERS ABRKT2 ABRKT3 ABRKT4 ABRKT6 ABRKT10 AxBxC in./mm 3.75x2.75x1.50 95x70x38 4.50x3.50x1.50 114x89x38 6.00x5.00x1.50 152x127x38 10.00x6.88x2.00 254x175x51 13.50x10.12x3.50 343x257x89 FINGER GUARDS Designed to provide easy mounting of compact axial fans on enclosure panels. Brackets can be used for general air circulation or to direct air at problem areas. All sizes are .100-in. aluminum. Package quantity of 1 bracket. Fans must be ordered separately. Used with Fan Catalog Number A2AXFN24 D in./mm 2.38/60 E in./mm — F in./mm 1.75/44 G in./mm .50/13 H in./mm .37/9 J in./mm .62/16 A3AXFN, A3AXFN24 2.75/70 — 2.50/64 .50/13 .37/9 .62/16 A4AXFNPG, A4AXFNGQ, A4AXFN or A4AXFN2 A6AXFNPG, A6AXFNGQ, A6AXFN or A6AXFN2 A10AXFNPG, A10AXFNGQ, A10AXFN or A10AXFN2 3.50/89 — 3.00/76 1.00/25 .38/10 .62/16 6.50/51 — 5.00/127 .94/24 .38/10 1.00/25 8.50/216 4.00/102 4.00/102 1.06/27 .62/16 2.00/51 One finger guard is included with each Compact Axial Fan and Cooling Fan Package. Additional Finger Guards can be mounted on either side of the fan for maximum safety. All guards are chromeplated and meet UL 507 .25-in. plug gauge test. CATALOG NUMBERS AGARD2 AGARD3 AGARD4 AGARD6 AGARD10 EQUIPMENT PROTECTION Use on Compact Axial Fan Catalog Numbers A2AXFN24 A3AXFN, A3AXFN24 A4AXFNPG, A4XFNGQ, A4AXFN, A4AXFN2 A6AXFNPG, A6AXFNGQ, A6AXFN, A6AXFN2 A10AXFNPG, A10AXFNQR , A10AXFN, A10AXFN2 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 255 4 Fresh Air Enclosure Cooling Axial Fans and Accessories RACK-MOUNTABLE ASSEMBLIES FAN TRAYS UEB17H 2EB17H 3EB17H INDUSTRY STANDARDS SPECIFICATIONS • • • UL recognized • • C SA Certified Motors C E 115/230 VAC 24 VDC 5 0/60 Hz APPLICATION Fan trays are a versatile solution to cooling card cages and racks. Redundant cooling with optional failure detection makes this air mover the obvious choice for sensitive equipment. Minimal rack space and repositionable fans are suited to today’s smaller enclosures. FEATURES • • • • • • • • • • lim 1.75 in. (44 mm) Panel Height S 19-in. rack mountable F ield adjustable fan strips to optimize air flow E asy access to fan tray from front and back Simplified installation without the need for side access Support bracket E xhaust Guard 6-inch Power Cord AC trays, Terminal block on DC trays Permanently lubricated ball bearing motors 100% functionally tested Performance Curves (Inches of Water to CFM) Performance Curves (Pa to m3/hr) 80 0.8 UEB,1EB-17H&T - 60hz UEB,1EB-17H&T - 50hz 2EB-17H&T - 60hz 2EB-17H&T-50hz 3EB-17H&T-60hz 3EB-17H&T-50hz 0.7 0.6 0.5 0.4 UEB,1EB-17H&T - 60hz UEB,1EB-17H&T - 50hz 2EB-17H&T - 60hz 2EB-17H&T-50hz 3EB-17H&T-60hz 3EB-17H&T-50hz 60 Pa Inches of Water 4 Fresh Air Enclosure Cooling Fan Trays 40 0.3 20 0.2 0.1 0 256 0 Cooling 200 400 CFM 600 800 1000 0 0 SUBJECT TO CHANGE WITHOUT NOTICE 200 400 600 800 1000 1200 1400 1600 m3/hr EQUIPMENT PROTECTION &DVH:LGWK ( 81,7,=(''(6,*1 02'8/$5'(6,*1 :KHUHRQO\RQH IDQVWULSLV UHTXLUHGD XQLWL]HG8IDQ WUD\LV UHFRPPHQGHG &DVH:LGWK ( 7HOHVFRSLQJ5HDU 6XSSRUW%UDFNHWV LQ0D[LPXP 3DQHO+HLJKW >@ &DVH 'HSWK >@ 3DQHO:LGWK ( 3DQHO:LGWK ( &DVH'HSWK >@ 89081542 Performance Data Rack-Mountable Assemblies ELECTRICAL DATA Rated Voltage Frequency (Hz) RPM Nominal Current Maximum (Amps) Power Consumption Maximum (Watts) Maximum Operating Temperature (°F/°C) UEB17H Catalog Numbers Nominal Current Maximum @50/60 Hz (Amps) Power Consumption Maximum @ 50/60 Hz (Watts) Free Airflow @ 50/60 Hz (CFM)* Free Airflow @ 50/60 Hz (m3/hr.)* Number of Fans Unit Dimensions H x W x D (In./mm) Weight (lb./kg) 2EB17H Catalog Numbers Nominal Current Maximum @50/60 Hz (Amps) Power Consumption Maximum @ 50/60 Hz (Watts) Free Airflow @ 50/60 Hz (CFM)* Free Airflow @ 50/60 Hz (m3/hr.)* Number of Fans Unit Dimensions H x W x D (In./mm) Weight (lb./kg) 3EB17H Catalog Numbers Nominal Current Maximum @50/60 Hz (Amps) Power Consumption Maximum @ 50/60 Hz (Watts) Free Airflow @ 50/60 Hz (CFM)* Free Airflow @ 50/60 Hz (m3/hr.)* Number of Fans Unit Dimensions H x W x D (In./mm) Weight (lb./kg) EQUIPMENT PROTECTION 115 VAC 50/60 3100 0.4 42 230 VAC 50/60 3100 0.2 42 158/70 24 VDC DC 3000 0.8 21 UEB17H115 .4 42 315 536 UEB17H24 .8 21 330 561 7.8/3.4 UEB17H230 .2 42 315 536 3 1.75 x 19.00 x 8.00/44 x 482 x 203 7.8/3.4 2EB17H115 .9 84 630 1071 2EB17H230 .5 84 630 1071 — — — — — — — — 3EB17H115 1.4 126 945 1607 3EB17H230 .8 126 945 1607 — — — — — — — — 6 1.75 x 19.00 x 18.75/44 x 482 x 476 10.2/4.5 10.2/4.5 9 1.75 x 19.00 x 18.75/44 x 482 x 476 12.5/5.5 12.5/5.5 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 4 7.6/3.3 Cooling 257 Fresh Air Enclosure Cooling Fan Trays 4 Fresh Air Enclosure Cooling Fan Trays 19-IN. RACK-MOUNTABLE TRAY APPLICATION Fan trays enhance the natural convection airflow within a cabinet when installed with other 19-in. rack-mount equipment. FEATURES • • • • an trays available with either three or six 4-in. fans F Includes 72-in. (1829-mm) power cord with IEC 320 standard power socket Power cord plugs into standard 115 VAC outlet Lighted rocker switch provides on-off control and indicates when fans are on FINISH • R AL 9005 black, lightly textured polyester powder paint ACCESSORIES Rack mounting hardware Performance Data 19-in. Rack-Mountable Tray ELECTRICAL DATA Rated Voltage Frequency (Hz) Power Consumption (Watts) CATALOG NUMBERS Maximum Airflow (CFM) Maximum Airflow (m3/hr.) Nominal Airflow Capacity (CFM) Nominal Airflow Capacity (m3/hr.) UNIT CONSTRUCTION Sound Pressure (dBA) Maximum Operating Temperature Range (°F/°C) Maximum Static Pressure (in. WC) Number of Fans C (in./mm) 258 Cooling SUBJECT TO CHANGE WITHOUT NOTICE 115 60 45 115 60 90 A19FT3B 253 430 102 173 A19FT6B 506 860 102 173 41 158/70 0.27 3 8.10/206 41 158/70 0.27 6 12.96/329 EQUIPMENT PROTECTION RACK-MOUNT FAN SPEED CONTROL APPLICATION Perfect for offices, classrooms and other noise-sensitive areas. Fan Speed Control optimizes airflow in a cabinet or rack, balancing air volume requirements with noise level and power use. FEATURES • • • • • INDUSTRY STANDARDS UL 508 Listed; File No. E249700 cUL Listed per CSA C22.2 No. 14; File No. E249700 ontinuously variable fan speed control knob with minimum C speed adjustment Uses 1 RU rack space Steel construction Two NEMA 5-15R outlets provide power to fan Six-foot (1.83-m) power cord plugs into standard 120 V 60 Hz outlet FINISH • A19FANSC: RAL 9005 black polyester powder paint Performance Data Rack-Mount Fan Speed Controls CATALOG NUMBERS A19FANSC ELECTRICAL DATA Rated Voltage Maximum Nominal Current (Amps) Temperature Settings (°F) Temperature Settings (°C) DESIGN DATA Description Application 120 VAC 4 86, 95, 104, 113 30, 35, 40, 45 19-in. Rack-Mount Fan Speed Control Fan speed adjusted manually 4 89084921 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 259 Fresh Air Enclosure Cooling Fan Trays 4 Fresh Air Enclosure Cooling Packaged Blowers RACK-MOUNTABLE BLOWERS PACKAGED BLOWERS 1EB52H115B 1EB52H115A 2EB300 2EB3500 2EB412 4EB300 2EB512 2EB612 INDUSTRY STANDARDS 1EB Models UL recognized CSA Certified Motors CE APPLICATION Fanpack packaged blowers are filtered inlet redundant fan packages. The compact size of the “B” models result in minimal intrusion into the enclosure. Standard packaged blowers offer reliable rack cooling in a variety of case styles. Two exhaust styles are available with air flowing out the rear or out the top. Specify exhaust style (R or T) when ordering. Multi-exhaust packaged blowers feature top and rear exhausts, for a wide, deep airflow pattern. Designed with two separate blowers inside, multi-exhaust blowers also offer redundancy and increased airflow. 2EB Models FEATURES • • • • • • • ermanent, Washable Aluminum Filter P 19-in. Rack Mountable Brushed Aluminum Grille E xhaust Guard Power Cord Permanently lubricated ball bearing motors 100% functionally tested 4EB Models SPECIFICATIONS • • 115/230 VAC 5 0/60 Hz 260 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data 1EB Models ELECTRICAL DATA Rated Voltage Frequency (Hz) Maximum Operating Temperatur (°F/°C) ”A” Models Catalog Numbers Free Airflow (CFM/M3/hr.) RPM Nominal Run Current Maximum (Amps) Nominal Start Current Maximum (Amps) Power Consumption (Watts) Weight (lb./kg) ”B” Models Catalog Numbers Free Airflow (CFM/M3/hr.) RPM Nominal Run Current Maximum (Amps) Nominal Start Current Maximum (Amps) Power Consumption (Watts) Weight (lb./kg) 1EB52HxxxB Models 115 50/60 140/60 230 50/60 140/60 1EB52H115A 320/544 3300 .52 1.00 62 14/6.3 1EB52H230A 320/544 3300 .26 .50 62 14/6.3 1EB52H115B 235/400 3100 .55 .80 44 8/3.6 1EB52H230B 235/400 3100 .31 .40 44 8/3.6 1EB52HxxxA Models 17 [432] 17 [432] 3.43 [87] 0.50 [13] 18 [457] 1.12 [28] 5.21 [132] Brushed Aluminium Grille Aluminium Filter Washable, Replaceable 2.60 [66] 9.25 [235] 13.70 [348] 2.25 [57] 89081701 18 [457] 0.50 [13] 2.61 1.12 [28][67] 5.21 [132] Aluminium Filter Brushed Aluminium Grille Washable, Replaceable 2.25 [57] 5.18 [132] 3.00 [76] 4 13.70 [348] 1EB Models 250 0.8 1EB52HXXXA - 60hz 1EB52HXXXA - 50hz 1EB52HXXXB-60hz 1EB52HXXXB-50hz 0.6 0.5 150 0.4 100 0.3 0.2 50 0.1 0 1EB52HXXXA - 60hz 1EB52HXXXA - 50hz 1EB52HXXXB-60hz 1EB52HXXXB-50hz 200 Pa Inches of Water 0.7 0 EQUIPMENT PROTECTION 100 200 CFM 300 400 0 0 100 200 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 300 400 M3/hr. 500 600 Cooling 261 Fresh Air Enclosure Cooling Packaged Blowers 4 Fresh Air Enclosure Cooling Packaged Blowers Performance Data 2EB Models ELECTRICAL DATA Rated Voltage Frequency (Hz) Maximum Operating Temperatur (°F/°C) 2EB300R Models Catalog Numbers Free Airflow (CFM/M3/hr.) RPM Nominal Run Current Maximum (Amps) Power Consumption (Watts) Weight (lb./kg) 2EB3500R Models Catalog Numbers Free Airflow (CFM/M3/hr.) RPM Nominal Run Current Maximum (Amps) Power Consumption (Watts) Weight (lb./kg) 2EB412R Models Catalog Numbers Free Airflow (CFM/M3/hr.) RPM Nominal Run Current Maximum (Amps) Power Consumption (Watts) Weight (lb./kg) 2EB512R Models Catalog Numbers Free Airflow (CFM/M3/hr.) RPM Nominal Run Current Maximum (Amps) Power Consumption (Watts) Weight (lb./kg) 2EB512T Models Catalog Numbers Free Airflow (CFM/M3/hr.) RPM Nominal Run Current Maximum (Amps) Power Consumption (Watts) Weight (lb./kg) 2EB612R Models Catalog Numbers Free Airflow (CFM/M3/hr.) RPM Nominal Run Current Maximum (Amps) Power Consumption (Watts) Weight (lb./kg) 115 50/60 104/40 230 50/60 104/40 2EB300R115 125/212 3000 .9 70 16/17.3 2EB300R230 125/212 3000 .5 70 16/17.3 2EB3500R115 290/493 3050 1.8 125 17/7.7 2EB3500R230 290/493 3050 .9 125 17/7.7 2EB412R115 375/637 3100 1.8 200 22/10 2EB412R230 375/637 3100 .8 200 22/10 2EB512R115 425/722 1700 1.3 140 25/11.3 2EB512T115 425/722 1700 1.3 140 25/11.3 2EB612R115 800/1359 1650 2.2 220 41/18.6 2EB612R230 800/1359 1650 1.0 220 41/18.6 Design Data 2EB Models CATALOG NUMBERS 2EB300R115 2EB3500R115 2EB412R115 2EB512R115 2EB512T115 2EB612R115 262 Cooling PMax in./mm 5.25/133 5.25/133 7.00/178 8.75/222 8.75/222 10.50/267 A in./mm 4.30/109 4.38/111 4.23/107 4.13/105 4.13/105 4.38/111 B in./mm 2.05/52 4.56/116 3.15/80 3.63/92 3.63/92 3.99/101 SUBJECT TO CHANGE WITHOUT NOTICE C in./mm — — — — .80/20 — D in./mm — — — — 3.40/86 — E in./mm 8.22/209 7.17/182 8.22/209 8.22/209 9.61/244 10.22/620 F in./mm — 1.75/44 — — — — EQUIPMENT PROTECTION 2EB Models B 17.00 [432] A B C D AIR EXHAUST "T" VERSION 89081699 19.00 [483] .32 [8] E F (3500 ONLY) AIR EXHAUST "R" VERSION P MAX 2EB Models 550 2EB3500- 60hz 2EB3500- 50hz 2EB300- 60hz 2EB300- 50hz 0.8 0.7 0.6 450 250 0.5 0.4 0.3 0.2 0.1 0 4 200 150 100 50 0 200 CFM 400 0 600 100 200 300 M3/hr. 400 500 600 1.2 350 300 Pa 1.0 2EB612- 60Hz 2EB612- 50hz 2EB412- 60Hz 2EB412- 50Hz 2EB512- 60hz 2EB512- 50hz 400 2EB612- 60Hz 2EB612- 50hz 2EB412- 60Hz 2EB412- 50Hz 2EB512- 60hz 2EB512- 50hz 1.4 0.8 250 200 0.6 150 0.4 100 0.2 0 0 450 1.6 Inches of Water 2EB3500- 60hz 2EB3500- 50hz 2EB300- 60hz 2EB300- 50hz 350 Pa Inches of Water 1 0.9 50 0 EQUIPMENT PROTECTION 200 400 600 CFM 800 1000 1200 0 0 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 500 M3/hr. 1000 1500 Cooling 263 Fresh Air Enclosure Cooling Packaged Blowers Performance Data 4EB Models ELECTRICAL DATA Rated Voltage Frequency (Hz) Maximum Operating Temperatur (°F/°C) 4EB300RT Models Catalog Number Free Airflow (CFM/M3/hr.) RPM Nominal Run Current Maximum (Amps) Power Consumption (Watts) Weight (lb./kg) 115 50/60 104/40 4EB300RT115 225/382 2900 1.8 130 21/9.5 Design Data 4EB Models PMax in./mm 5.25/133 CATALOG NUMBERS 4EB300RT115 A in./mm 4.30/109 B in./mm 2.05/52 C in./mm 7.25/184 D in./mm 2.70/69 E in./mm 12.88/327 F in./mm — 4EB Models C A B B D AIR EXHAUST "T" VERSION 89081700 F (3500 ONLY) E .32 [8] 19.00 [483] AIR EXHAUST "R" VERSION P MAX 4EB Models 450 1.6 400 1.4 1.2 300 1.0 0.8 150 0.4 100 0.2 264 Cooling 250 200 0.6 0 (%+] (%K] 350 (%+] (%K] Pa Inches of Water 4 Fresh Air Enclosure Cooling Packaged Blowers 50 0 100 200 300 CFM 400 500 600 0 0 SUBJECT TO CHANGE WITHOUT NOTICE 200 400 600 800 M3/hr. 1000 1200 EQUIPMENT PROTECTION Notes 4 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 265 Fresh Air Enclosure Cooling Packaged Blowers 4 Fresh Air Enclosure Cooling Air Movers RACK-MOUNTABLE FAN PACKAGE AIR MOVERS INDUSTRY STANDARDS UL Component Recognized; File No. E61997 EIA RS-310-D CSA certified (blower motor only) • • • • otating components are suspended on neoprene shock-mounts R Three-conductor power cord (five feet long) The unit is self-supporting with 16 gauge steel flanges notched per EIA RS-310-D. A n exhaust grille and filter package (catalog number AEXGR275) is required and must be ordered separately APPLICATION SPECIFICATIONS FEATURES ACCESSORIES • 16 gauge steel housing For enclosure or 19-in. rack applications, the Blower Fan Package provides the maximum amount of cooling air in the least amount of FINISH space by utilizing 115 volt AC, 60/50 hertz, single-phase input power. Engineered for 20,000 hours of continuous operation when properly • Blower housing is black enamel. • Grille is brushed stainless steel. powered. • • • • • • Exhaust Grille and Filter I ntake grille is easily removed with two captive thumbnuts Filter Adhesive Washable aluminum filter Temperature Control Switch Single phase motor powers the statically balanced blower Motor is thermally protected and cooled by incoming forced air Direct drive induction motor contains permanently lubricated ball bearings Lubricant protects from -20 F to 298 F (-29 C to 148 C) Performance Data Rack-Mountable Fan Package CATALOG NUMBERS ADB275 ELECTRICAL DATA Rated Voltage Frequency Free Airflow (CFM) RPM Nominal Current Maximum (Amps) Power Consumption (Watts) SOUND LEVEL Sound Pressure (dBA) UNIT CONSTRUCTION Weight (lb./kg) EXHAUST GRILLE CATALOG NUMBERS Catalog Number 115 50/60 230/275 2580/3100 1.2 84 56 15/7 AEXGR275* * Exhaust grille sold separately 266 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Rack-Mountable Fan Package EXHAUST GRILLES AND REPLACEMENT FILTERS 4 Located at air discharge side of an enclosure using Blower Package ADB275. Polished stainless steel grille is 65 percent open and offers low resistance to airflow. Expanded aluminum filter (included with each grille) is easily removed for cleaning from outside the enclosure. Mounting hardware is furnished. CUTOUT DIMENSIONS Performance Data Exhaust Grilles and Replacement Filters for Rack-Mountable Fan Package CATALOG NUMBERS UNIT CONSTRUCTION Dimensions H x W (in./mm) Filter Size (in./mm) ACCESSORIES Replacement Filters: Catalog Number Description EQUIPMENT PROTECTION AEXGR275 5.75/146 x 19.00/483 4.98/126 x 16.56/421 AFLTR275AL Aluminum Filter Replacement (5 per package) PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 267 Fresh Air Enclosure Cooling Air Movers 4 Fresh Air Enclosure Cooling Air Movers FILTER BOX FANS INDUSTRY STANDARDS Motor UL Recognized Motor CSA APPLICATION Thermal filter boxes are high volume air movers that require minimal enclosure space. Repositionable mounting ears allow the fans to be mounted internally or externally, and used for either intake or exhaust. FEATURES • • • • • • Inlet Guard Outlet Guard Power Cord 5 -15 plug available on catalog numbers ending with “M” only Permanently lubricated ball bearing motors 100% functionally tested SPECIFICATIONS • • 115 VAC 5 0/60Hz Performance Data Filter Box Fans ELECTRICAL DATA Rated Voltage Frequency (Hz) Maximum Operating Temperature (°F/°C) 1RB65 Models Catalog Numbers Free Airflow (CFM/M3/hr.) RPM Nominal Run Current Maximum (Amps) Nominal Start Current Maximum (Amps) Power Consumption (Watts) Filter Weight (lb./kg) 1RB80 Models Catalog Numbers Free Airflow (CFM/M3/hr.) RPM Nominal Run Current Maximum (Amps) Nominal Start Current Maximum (Amps) Power Consumption (Watts) Filter Weight (lb./kg) 1RB100 Models Catalog Numbers Free Airflow (CFM/M3/hr.) RPM Nominal Run Current Maximum (Amps) Nominal Start Current Maximum (Amps) Power Consumption (Watts) Filter Weight (lb./kg) 1RB120 Models Catalog Numbers Free Airflow (CFM/M3/hr.) RPM Nominal Run Current Maximum (Amps) Nominal Start Current Maximum (Amps) Power Consumption (Watts) Filter Weight (lb./kg) 268 Cooling 115 50/60 104/40 115 50/60 104/40 1RB65 275/493 3000 .85 1.2 70 N/A 8/3.5 1RB65M 275/493 3000 .85 1.2 70 Aluminum 8/3.5 1RB80 390/699 1600 1.1 1.5 80 N/A 10/4.5 1RB80M 390/699 1600 1.1 1.5 80 Aluminum 10/4.5 1RB100 725/1299 1600 1.2 1.5 90 N/A 12/5.4 1RB100M 725/1299 1600 1.2 1.5 90 Aluminum 12/5.4 1RB120 1200/2151 1500 1.5 2.5 160 N/A 24/10.8 1RB120M 1200/2151 1500 1.5 2.5 160 Aluminum 24/10.8 SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Curves Filter Box 250 0.6 1RB65 60Hz 1RB65 50Hz 1RB80 60Hz 1RB80 50Hz 0.4 150 0.3 100 0.2 50 0.1 0 0 100 200 CFM 300 400 0 500 0 100 200 300 400 M3/hr. 500 600 700 160 1RB100 60Hz 1RB100 50Hz 1RB120 60Hz 1RB120 50Hz 0.70 0.60 0.50 120 100 0.40 80 0.30 60 0.20 40 0.10 20 0 250 500 750 1000 1250 1500 1750 2000 CFM 1RB100 60Hz 1RB100 50Hz 1RB120 60Hz 1RB120 50Hz 140 Pa Inches of Water 0.80 0 1RB65 60Hz 1RB65 50Hz 1RB80 60Hz 1RB80 50Hz 200 Pa Inches of Water 0.5 0 0 250 500 750 1000 1250 1500 1750 2000 M3/hr. Ø 0.22 [6] (4 Holes) 4 E 89081776 B C D 0.32 [8] A Design Data Filter Box CATALOG NUMBERS 1RB65 1RB65M 1RB80 1RB80M 1RB100 1RB100M 1RB120 1RB120M EQUIPMENT PROTECTION A in./mm 4.50/114 4.50/114 4.50/114 4.50/114 4.50/114 4.50/114 7.38/187 7.38/187 B in./mm 8.88/226 8.88/226 8.88/226 8.88/226 12.13/308 12.13/308 15.13/384 15.13/384 C in./mm 9.56/243 9.56/243 9.56/243 9.56/243 12.81/325 12.81/325 15.81/402 15.81/402 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM D in./mm 10.13/257 10.13/257 10.13/257 10.13/257 13.38/340 13.38/340 16.38/416 16.38/416 E in./mm 4.88/124 4.88/124 4.88/124 4.88/124 6.13/156 6.13/156 9.00/229 9.00/229 Cooling 269 Fresh Air Enclosure Cooling Air Movers 4 Fresh Air Enclosure Cooling Blowers CENTRIFUGAL BLOWERS BLOWERS INDUSTRY STANDARDS UL Recognized CSA Certified Motors APPLICATION Single Centrifugal Blowers are compact for the maximum in spot cooling applications. Single centrifugal blowers can be mounted in any position for effective air movement. Dual Centrifugal Blowers are designed for applications where space limitations are a problem. Mountable in any position, these blowers provide dual blasts from separate housings mounted on a reliable motor. FEATURES • 100% Functionally Tested SPECIFICATIONS • • 115/230 VAC 5 0/60 Hz Performance Data 1NB Models ELECTRICAL DATA Rated Voltage Frequency (Hz) Maximum Operating Temperature (°F/°C) 1NB412 Models Catalog Numbers Free Airflow (CFM/M3/hr.) RPM Nominal Run Current Maximum (Amps) Nominal Start Current Maximum (Amps) Power Consumption (Watts) Weight (lb./kg) 115 50/60 104/40 230 50/60 104/40 1NB412115 200/340 3100 1.2 2.1 120 6/2.7 1NB412230 200/340 3100 0.6 1.5 120 6/2.7 Design Data 1NB Models CATALOG NUMBERS 1NB412115 1NB412230 270 Cooling A in./mm 6.81/173 6.81/173 B in./mm 6.14/156 6.14/156 C in./mm 3.84/96 3.84/96 D in./mm 3.29/84 3.29/84 F in./mm 0.31/8 0.31/8 G in./mm 0.62/16 0.62/16 H in./mm 4.66/118 4.66/118 SUBJECT TO CHANGE WITHOUT NOTICE I in./mm 4.03/102 4.03/102 J in./mm 0.31/8 0.31/8 K in./mm 0.72/18 0.72/18 L in./mm 3.22/82 3.22/82 M in./mm 7.47/190 7.47/190 HD in./mm 0.28/7 0.28/7 EQUIPMENT PROTECTION 1NB Models H I J G F B ± .06 [2] E K D C A ± .06 [2] HD L M ± .13 [3] 89081796 Performance Curves 1NB Models 500 1.8 1.4 350 300 1.2 1.0 Pa Inches of Water 1.6 0.8 250 4 200 150 0.6 0.4 100 50 0.2 0 1% 1%K] 450 400 1% 1%K] 0 50 EQUIPMENT PROTECTION 100 150 200 CFM 250 300 350 0 0 150 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 300 450 M3/hr. 600 750 Cooling 271 Fresh Air Enclosure Cooling Blowers 4 Fresh Air Enclosure Cooling Blowers Performance Data 2NB Models ELECTRICAL DATA Rated Voltage Frequency (Hz) Maximum Operating Temperature (°F/°C) 2NB300 Models Catalog Numbers Free Airflow (CFM/M3/hr.) RPM Nominal Run Current Maximum (Amps) Nominal Start Current Maximum (Amps) Power Consumption (Watts) Weight (lb./kg) 2NB3500 Models Catalog Numbers Free Airflow (CFM/M3/hr.) RPM Nominal Run Current Maximum (Amps) Nominal Start Current Maximum (Amps) Power Consumption (Watts) Weight (lb./kg) 2NB412 Models Catalog Numbers Free Airflow (CFM/M3/hr.) RPM Nominal Run Current Maximum (Amps) Nominal Start Current Maximum (Amps) Power Consumption (Watts) Weight (lb./kg) 2NB424 Models Catalog Numbers Free Airflow (CFM/M3/hr.) RPM Nominal Run Current Maximum (Amps) Nominal Start Current Maximum (Amps) Power Consumption (Watts) Weight (lb./kg) 2NB512 Models Catalog Numbers Free Airflow (CFM/M3/hr.) RPM Nominal Run Current Maximum (Amps) Nominal Start Current Maximum (Amps) Power Consumption (Watts) Weight (lb./kg) 115 50/60 104/40 230 50/60 104/40 2NB300115 130/221 2900 0.9 1.2 70 6/2.7 2NB300230 130/221 2900 0.5 0.6 70 6/2.7 2NB3500115 300/510 3050 1.8 2.5 125 8/3.6 2NB3500230 300/510 3050 0.9 1.3 125 8/3.6 2NB412115 360/612 3000 1.6 4 225 9/4.1 2NB412230 360/612 3000 0.8 2 225 9/4.1 2NB424115 595/1011 3100 4 6.8 400 12/5.4 2NB424230 595/1011 3100 2 3.5 400 12/5.4 2NB512115 500/850 1700 1.5 3.5 130 14/6.3 2NB512230 500/850 1700 0.8 1.7 130 14/6.3 Design Data 2NB Models CATALOG NUMBERS 2NB300XXX 2NB3500XXX 2NB412XXX 2NB424XXX 2NB512XXX 272 Cooling A in/mm 5.19/132 5.57/141 6.73/171 8.06/205 8.06/205 B in/mm 5.25/133 5.07/129 6.37/162 7.00/178 7.75/197 C in/mm 2.19/56 2.00/51 2.59/66 3.13/80 3.44/87 D in/mm 2.50/64 2.75/70 2.53/64 3.25/83 4.06/103 F in/mm .28/7 .38/10 .38/10 .63/16 .31/8 G in/mm .43/11 .78/20 -/.13/3 .63/16 H in/mm 2.13/54 4.37/111 3.22/82 3.50/89 3.66/93 SUBJECT TO CHANGE WITHOUT NOTICE I in/mm 2.63/67 5.25/133 4.03/102 4.13/105 4.25/108 J in/mm .22/6 .38/10 .27/7 .69/18 .31/8 K in/mm .42/11 .50/13 .68/17 1.12/28 .63/16 L in/mm 3.87/98 3.00/76 3.31/84 3.63/92 3.63/92 M HD in/mm in/mm 8.69/221 .25/6 13.80/350 .22/6 10.62/270 .28/7 11.25/286 .25/6 11.56/294 .28/7 EQUIPMENT PROTECTION 2NB Models J F L ± .06 [2] I J I B ± .06 [2] G D K C J I K H A ± .06 [2] H M ± .06 [2] I G C A ± .06 [2] Mounting Flange for 2NB3500 HD H L D F HD 89081797 2.5 0 100 200 300 400 500 600 700 800 900 CFM 2 1.5 1 0.5 0 0 100 200 300 400 500 600 700 CFM 1%K] 1%+] 500 400 300 EQUIPMENT PROTECTION 1000 M3/hr. 1500 0 0 50 100 150 200 250 300 350 400 CFM 4 1%K] 1%K] 1%K] 1%+] 150 100 50 100 500 1%K] 1%K] 1%K] 1%+] 200 200 0 1.0 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 250 600 1% 1%K] 1%K] 1%+] Pa 450 400 350 300 250 200 150 100 50 0 1%K] 1%+] Inches of Water 1% 1%K] 1%K] 1%+] Inches of Water 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 Pa Pa Inches of Water Performance Curves 2NB Models 0 200 400 600 800 1000 1200 M3/hr. PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 0 0 100 200 300 400 M3/hr. 500 600 Cooling 273 Fresh Air Enclosure Cooling Blowers 4 Fresh Air Enclosure Cooling Motorized Impellers AC MOTORIZED IMPELLERS MOTORIZED IMPELLERS FEATURES • • • • • uiet, space-saving fresh air cooling Q Backward curved blades with high efficiency air flow Clockwise rotation as viewed from air intake side Permanently lubricated double-sealed ball bearings Impeller blades made of plastic PA66, galvanized steel or aluminum SPECIFICATIONS • • • • • • odels that deliver 147– 1558 CFM (250 – 2647 M 3 /Hr) M Maximum operating temperature of 140°F (60°C) For 115 volt AC 60 hz or 230 volt AC 50/60 hz power input voltage with +/- 10% tolerance. 5 4 inch (137cm) lead length S eparate capacitor included Optional inlet ring adds 5% air flow NOTES Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. Impeller General Diameter Blade Voltage 175=175mm Design A=AC volt B=Backward D=DC Volt Curve INDUSTRY STANDARDS UL Recognized CE APPLICATION Specific Internal Voltage Use 11=115 AC Impeller 23=230 AC 24=24 DC Height 48=48 DC 71=71mm Thermal AC Motorized Impellers offer a quiet, compact cooling option. Slim space-saving design compared to centrifugal blowers that allow multiple mounting options. Performance Data AC Motorized Impellers CATALOG NUMBERS AB1331196701 AB1332396701 AB1751171701 AB1752371701 AB1901169901 AB1902369901 AB2201171901 AB2202371901 AB2251110901 AB2252310901 AB2501199901 AB2502399901 AB2801193901 AB2802393901 AB3201116101 AB3202316101 AB3551117101 AB3552317101 Diameter in./mm 5.24/133 5.24/133 6.89/175 6.89/175 7.48/190 7.48/190 8.78/223 8.78/223 8.86/225 8.86/225 9.88/251 9.88/251 11.06/281 11.06/281 12.52/318 12.52/318 14.13/359 14.13/359 VAC 115 230 115 230 115 230 115 230 115 230 115 230 115 230 115 230 115 230 Power Draw Hz Watts 60 30 50/60 28/30 60 44 50/60 39/44 60 109 50/60 87/109 60 120 50/60 95/120 60 195 50/60 147/195 60 246 50/60 174/246 60 313 50/60 220/313 60 161 50/60 117/161 60 172 50/60 172/250 CFM 173 147/173 294 255/294 384 343/384 608 564/608 834 712/834 846 794/846 1033 939/1033 1244 1095/1244 1558 1398/1558 Free Air Flow M3/Hr. RPM 294 3150 250/294 2725/3150 500 2875 433/500 2515/2875 652 2930 583/652 2600/2930 1033 2600 958/1033 2400/2600 1417 3100 1210/1417 2800/3100 1437 2760 1349/1437 2600/2760 1755 2850 1595/1755 2600/2850 2114 1600 1860/2114 1400/1600 2647 1590 2375/2647 1400/1590 Static Pressure In H2O Pa .84 209 .60/.84 149/209 1.08 269 .83/1.08 207/269 1.75 436 1.31/1.75 326/436 1.78 443 1.43/1.78 356/443 2.67 665 1.91/2.67 476/665 2.33 580 1.98/2.33 493/580 2.83 705 2.32/2.83 578/705 1.48 369 1.08/1.48 269/369 1.99 496 1.48/1.99 369/496 Max. Temp °F/°C 140/60 140/60 140/60 140/60 104/40 104/40 140/60 104/40 140/60 140/60 140/60 140/60 140/60 113/45 140/60 140/60 104/40 104/40 Min. Temp °F/°C -13/-25 -13/-25 -13/-25 -13/-25 -13/-25 -13/-25 -13/-25 -13/-25 -13/-25 -13/-25 -13/-25 -13/-25 -13/-25 -13/-25 -13/-25 -13/-25 -13/-25 -13/-25 Shipping Weight lb./kg 2/.9 2/.9 2/.9 2/.9 3/1.4 3/1.4 4/1.6 4/1.6 4/1.6 4/1.6 6/2.9 6/2.9 7/3.3 7/3.3 8/3.8 8/3.8 10/4.9 10/4.9 Free air flow and static pressure listed at 60 hz. See Performance Curves for complete details. UL pending for AB355 models. 274 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Impeller Dimensions AC Motorized Impellers CATALOG NUMBERS Diameter (A) in./mm 5.24/133 6.89/175 7.48/190 8.78/223 8.86/225 9.88/251 11.06/281 12.52/318 14.13/359 AB133 AB175 AB190 AB220 AB225 AB250 AB280 AB320 AB355 Inside Diameter (B) in./mm 3.67/93 5.16/131 5.16/131 6.36/162 6.06/154 6.85/174 7.48/190 8.66/220 9.84/250 Height (C) in./mm 2.36/60 2.44/62 2.44/62 2.52/64 3.50/89 3.36/85 3.24/82 5.51/140 5.79/147 Height (D) in./mm 3.78/96 2.80/71 2.70/69 2.80/71 4.21/107 3.90/99 3.64/93 6.10/155 6.50/165 Motor Height (E) in./mm --2.80/71 ---3.82/97 --- A B C D E See below for base mounting patterns AB133-AB280 AB133-AB280 4 89059014 Base Mounting Patterns For models AB133 thru AB280: 4 Holes on 2.28 (58.0 mm) bolt circle diameter. M4 x 5mm maximum thread depth. 1.25 (31.8 mm) diameter cutout. For models AB320 and AB355: 4 Holes on 3.54 (90.0 mm) bolt circle diameter. M6 x 12mm maximum thread depth. 3.00 (76.2 mm) diameter cutout. Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 275 Fresh Air Enclosure Cooling Motorized Impellers 4 Fresh Air Enclosure Cooling Motorized Impellers Inlet Ring Dimensions AC Motorized Impellers CATALOG NUMBERS Inlet Ring Part No. 101072120SP 101072121SP 101072121SP 101072123SP 101072124SP 101072125SP 101072126SP 101072127SP 101072129SP AB133 AB175 AB190 AB220 AB225 AB250 AB280 AB320 AB355 Diameter (A) in./mm 5.08/129 6.69/170 6.69/170 9.92/252 8.78/223 10.04/255 11.02/280 11.81/300 13.78/350 Height (B) in./mm .51/13 .55/14 .55/14 .83/21 1.10/28 1.30/33 1.38/35 1.06/27 1.22/31 Mounting (C)* in./mm 4.65/118 6.22/158 6.22/158 9.29/236 8.30/211 9.45/240 10.24/260 11.02/280 12.80/325 Number of Mounting Holes 4 4 4 3 4 4 4 4 6 Order Separately *Bolt Circle Diameter for equally spaced holes listed: Holes are .177 (4.5 mm) each. All inlet rings have 4 holes, except for 101072123SP which has 3 holes and 101072129SP has 6 holes. Inlet Ring C Mounting holes equally spaced (see table) Ø.177 (4.5mm) B A Impeller and Inlet Ring Interface Wheel/Inlet Ring Recommended Gap Motor Wiring Blue Green/Yellow L1 PSC Motor Black L2 Brown 89059015 276 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Curve for AB133 (airflow with inlet ring) AirFlow (M3/Hr.) 0 34 68 102 136 170 204 238 272 306 224 .90 199 .80 60 Hz .70 174 Static Pressure (in H2O) 50 Hz .50 124 .40 100 .30 75 .20 50 .10 25 Static Pressure (Pa) 149 .60 0 0 0 20 40 60 80 100 120 140 160 180 AirFlow (CFM) Performance Curve for AB175 (airflow with inlet ring) 0 85 170 AirFlow (M3/Hr.) 255 340 425 299 1.20 60 Hz .100 249 .80 199 50 Hz .60 149 .40 100 .20 50 Static Pressure (Pa) Static Pressure (in H2O) 4 510 0 0 0 50 100 150 200 250 300 AirFlow (CFM) EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 277 Fresh Air Enclosure Cooling Motorized Impellers Performance Curve for AB190 (airflow with inlet ring) AirFlow (M3/Hr.) 85 255 340 425 510 595 680 765 498 1.80 448 1.60 Static Pressure (in H2O) 170 398 60 Hz 1.40 349 1.20 299 1.00 Static Pressure (Pa) 0 2.00 249 50 Hz .80 199 .60 149 .40 100 .20 50 0 0 0 100 50 150 200 250 300 350 400 450 AirFlow (CFM) Performance Curve for AB220 (airflow with inlet ring) AirFlow (M3/Hr.) 170 340 510 679 849 1019 2.00 1189 498 1.80 448 1.60 398 1.40 349 60 Hz 1.20 299 50 Hz 1.00 249 .80 199 .60 149 .40 100 .20 50 0 0 100 200 300 400 500 600 700 Static Pressure (Pa) 0 Static Pressure (in H2O) 4 Fresh Air Enclosure Cooling Motorized Impellers 0 AirFlow (CFM) 278 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Curve for AB225 (airflow with inlet ring) AirFlow (M3/Hr.) 0 170 340 510 680 849 1019 1189 1359 1529 747 3.00 60 Hz 50 Hz 2.00 Static Pressure (in H2O) 623 498 1.50 374 1.00 249 .50 125 0 Static Pressure (Pa) 2.50 0 0 100 200 300 400 500 600 700 800 900 AirFlow (CFM) 4 Performance Curve for AB250 (airflow with inlet ring) AirFlow (M /Hr.) 3 0 170 340 510 680 849 1019 1189 1359 1529 2.50 623 60 Hz 498 2.00 1.50 374 1.00 249 .50 125 Static Pressure (Pa) Static Pressure (in H2O) 50 Hz 0 0 0 100 200 300 400 500 600 700 800 900 AirFlow (CFM) EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 279 Fresh Air Enclosure Cooling Motorized Impellers Performance Curve for AB280 (airflow with inlet ring) AirFlow (M3/Hr.) 0 340 680 1019 1359 1699 2039 3.50 871 747 3.00 60 Hz Static Pressure (in H2O) 498 2.00 50 Hz 1.50 374 1.00 249 .50 125 Static Pressure (Pa) 623 2.50 0 0 200 0 400 600 800 1000 1200 AirFlow (CFM) Performance Curve for AB320 (airflow with inlet ring) AirFlow (M3/Hr.) 0 255 510 765 1020 1274 1529 1784 2039 2294 398 1.60 60 Hz 1.40 348 1.20 299 1.00 249 50 Hz .80 199 .60 149 .40 100 .20 50 Static Pressure (Pa) Static Pressure (in H2O) 4 Fresh Air Enclosure Cooling Motorized Impellers 0 0 0 150 300 450 600 750 900 1050 1200 1350 AirFlow (CFM) Note: Without inlet ring, assume 5% reduction in air flow. 280 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Curve for AB355 (airflow with inlet ring) AirFlow (M3/Hr.) 0 340 2.00 680 1019 1359 1699 2039 2378 2718 498 60 Hz 1.80 448 1.60 398 349 50 Hz 1.20 299 1.00 249 .80 199 .60 149 .40 100 .20 50 0 Static Pressure (Pa) Static Pressure (in H2O) 1.40 0 0 200 400 600 800 1000 1200 1400 1600 AirFlow (CFM) 4 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 281 Fresh Air Enclosure Cooling Motorized Impellers 4 Fresh Air Enclosure Cooling Motorized Impellers DC MOTORIZED IMPELLERS FEATURES • • • • • • • • uiet, space-saving fresh air cooling Q Backward curved blades with high efficiency air flow Clockwise rotation as viewed from air intake side Permanently lubricated double-sealed ball bearings Impeller blades made of plastic PA66, galvanized steel or aluminum Brushless DC motor for excellent control Reverse polarity protected Every unit functionally tested before shipping SPECIFICATIONS • • • • • odels that deliver 100 – 565 CFM (170 – 960 M 3 /Hr) M Maximum operating temperature of 149°F (65°C) Input voltage +/- 25% tolerance 24 VDC, 48 VDC, select 12 VDC models Capable of working with PWM (Pulse Width Modulation) and linear controls for variable speed operation. 5 volt (2 pulse per rev) tach output. OPTIONS • • ptional inlet ring O Custom solutions available, including additional 12 volt DC models and custom wire connections NOTES Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. INDUSTRY STANDARDS UL Recognized CE APPLICATION Thermal DC Motorized Impellers offer a quiet, compact cooling option. Slim space-saving design compared to centrifugal blowers that allow multiple mounting options. Impeller General Diameter Voltage Blade 133=133mm A=AC volt Design D=DC Volt B=Backward Curve Specific Internal Voltage Use 12=12 DC Impeller 24=24 DC Height 48=48 DC 71=71mm 11=115 AC 23=230 AC Performance Data DC Motorized Impellers CATALOG NUMBERS DB1021254401 DB1022454401 DB1024854401 DB1331242401 DB1332442401 DB1334842401 DB1332491701 DB1334891701 DB1752455701 DB1754855701 DB1752469701 DB1754869701 DB2202471701 DB2204871701 282 Cooling Diameter in./mm 4.02/102 4.02/102 4.02/102 5.24/133 5.24/133 5.24/133 5.24/133 5.24/133 6.89/175 6.89/175 6.89/175 6.89/175 8.66/220 8.66/220 Power Draw VDC Watts 12 28 24 27 48 29 12 27 24 32 48 39 24 68 48 72 24 68 48 72 24 68 48 72 24 92 48 92 CFM 100 100 100 140 140 140 220 220 305 305 360 360 565 565 Free Air Flow M3/Hr. 170 170 170 238 238 238 373 373 518 518 611 611 960 960 RPM 6400 6300 6400 4600 4900 5300 4800 4800 4200 4200 3900 3900 2950 2950 SUBJECT TO CHANGE WITHOUT NOTICE Static Pressure In H2O Pa 1.7 423 1.7 423 1.7 423 1.4 348 1.4 348 1.4 348 1.6 399 1.6 399 2.3 573 2.3 573 1.8 448 1.8 448 2.0 498 2.0 498 Max. Temp °F/°C 149/65 149/65 149/65 149/65 149/65 149/65 149/65 149/65 149/65 149/65 149/65 149/65 149/65 149/65 Min. Temp °F/°C -4/-20 -4/-20 -4/-20 -4/-20 -4/-20 -4/-20 -4/-20 -4/-20 -4/-20 -4/-20 -4/-20 -4/-20 -4/-20 -4/-20 Shipping Weight lb./kg 1/.5 1/.5 1/.5 2/.9 2/.9 2/.9 2/.9 2/.9 3/1.4 3/1.4 3/1.4 3/1.4 4/1.8 4/1.8 EQUIPMENT PROTECTION Impeller Dimensions DC Motorized Impellers CATALOG NUMBERS Diameter (A) in. mm 4.00 102 5.25 133 5.25 133 6.89 175 6.89 175 8.66 220 DB102XX54 DB133XX42 DB133XX91 DB175XX55 DB175XX69 DB220XX71 Diameter (B) in. mm 2.80 71 3.70 94 3.70 94 5.16 131 5.16 131 6.28 160 Height (C) in. mm 1.78 45 1.35 34 2.35 60 1.87 48 2.46 63 2.47 63 Height (D) in. mm 2.13 54 1.65 42 3.58 91 2.15 55 2.70 69 2.80 71 Motor Height (E) ---2.41 --- ---61 --- A B C D E See below for base mounting patterns DB102-DB133-XX42 DB133-XX91-DB220 4 89059016 Base Mounting Patterns For models DB102-XX54 and DB133-XX42: 3 Holes on 2.21 (56 mm) bolt circle diameter. 8-32 x .19 maximum thread depth For all other models: 4 Holes on 2.28 (58.0 mm) bolt circle diameter. M4 x 5mm maximum thread depth. Visit www.HoffmanOnline.com to download 2D and 3D CAD drawings into the overall design of your electronic system. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 283 Fresh Air Enclosure Cooling Motorized Impellers 4 Fresh Air Enclosure Cooling Motorized Impellers Inlet Ring Dimensions DC Motorized Impellers CATALOG NUMBERS DB102 DB133 DB175 DB220 Inlet Ring Part No. 89070536 101072120SP 101072121SP 101072123SP Diameter (A) in. mm 4.00 102 5.08 129 6.69 170 9.92 252 Height (B) in. mm .25 6.4 .51 13 .55 14 .83 21 Number of Mounting Holes Mounting (C)* in. mm 3.70 94 4.65 118 6.22 158 9.29 236 3 4 4 3 *Bolt Circle Diameter for equally spaced holes listed: Holes are .177 (4.5 mm) each. All inlet rings have 4 holes, except for 10-1072-123 which has 3 holes. Inlet Ring Mounting holes equally spaced (see table) Ø.177 (4.5mm) C B A Motor Wiring Impeller and Inlet Ring Interface Wheel/Inlet Ring Recommended Gap Red (VDC Black (Return) MTR Blue (Tach Output) Yellow (Command Input) 89059017 Impeller Speed Control Interface PULL-UP 5.62K SCALE COMMAND INPUT (YELLOW) 24V LOW-PASS FILTER 20K 7.87K VCC 390 OHMS ANALOG INPUT DIGITAL OUTPUT TACH OUT (BLUE) LOGIC 24V DC Impellers can be speed controlled via the yellow input lead in either of two ways: 1. 250 Hz to 4kHz 10 VDC PWM signal. 2. 0 to 10 VDC analog signal (linear control). Command input (1 - 10 VDC) corresponds linearly from zero to max bus voltage applied to the motor. Command input must be above 1 VDC before any measurable voltage is applied to the motor. The applied voltage is roughly proportional to the motor speed. • With the yellow lead left open, the impeller will run at full speed. • With the yellow lead connected to the black lead, the impeller will stop. • The blue lead produces a 5 VDC Tach output, 2 pulses per revolution. 89059018 284 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Curve for DB102-XX54 (airflow with inlet ring) AirFlow (M3/Hr.) 0 34 68 102 136 170 204 448 1.60 399 1.40 349 1.20 299 1.00 249 .80 199 .60 149 .40 100 .20 50 0 0 20 40 60 80 100 120 Static Pressure (Pa) Static Pressure (in H2O) 1.80 0 AirFlow (CFM) 4 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 285 Fresh Air Enclosure Cooling Motorized Impellers Performance Curve for DB133-XX42 (airflow with inlet ring) AirFlow (M3/Hr.) 0 34 68 102 136 170 204 238 272 622 2.00 498 1.50 373 1.00 249 .50 124 0 0 20 40 60 80 100 120 140 160 Static Pressure (Pa) Static Pressure (in H2O) 2.50 0 AirFlow (CFM) Performance Curve for DB133-XX91 (airflow with inlet ring) AirFlow (M3/Hr.) 0 85 170 255 340 425 448 1.60 399 1.40 349 1.20 299 1.00 249 .80 199 .60 149 .40 100 .20 50 0 0 50 100 150 200 Static Pressure (Pa) 1.80 Static Pressure (in H2O) 4 Fresh Air Enclosure Cooling Motorized Impellers 0 250 AirFlow (CFM) 286 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Curve for DB175-XX55 (airflow with inlet ring) AirFlow (M3/Hr.) Static Pressure (in H2O) 85 170 255 340 425 510 595 623 2.00 498 1.50 374 1.00 249 .50 125 0 0 50 100 150 200 250 300 Static Pressure (Pa) 0 2.50 0 350 AirFlow (CFM) 4 Performance Curve for DB175-XX69 (airflow with inlet ring) AirFlow (M3/Hr.) 0 85 170 255 340 425 510 595 680 498 1.80 448 1.60 399 1.40 349 1.20 299 1.00 249 .80 199 .60 149 .40 100 .20 50 0 0 EQUIPMENT PROTECTION 50 100 150 200 250 AirFlow (CFM) PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM 300 350 Static Pressure (Pa) Static Pressure (in H2O) 2.00 0 400 Cooling 287 Fresh Air Enclosure Cooling Motorized Impellers 4 Fresh Air Enclosure Cooling Motorized Impellers Performance Curve for DB220-XX71 (airflow with inlet ring) AirFlow (M3/Hr.) 0 170 340 510 680 850 1019 623 498 1.50 374 1.00 249 .50 125 Static Pressure (in H2O) 2.00 0 0 100 200 300 400 500 600 Static Pressure (Pa) 2.50 0 AirFlow (CFM) 288 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Notes 4 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 289 Fresh Air Enclosure Cooling Motorized Impellers 4 Fresh Air Enclosure Cooling Accessories FILTER GRILLE PANEL ACCESSORIES APPLICATION Filter Grille Panels add valuable ventilation to a rack for either inlet or exhaust air. Used alone, filter grille panels allow adequate air flow on natural convection applications or in conjunction with an air moving device to provide filtered air intake. FEATURES • • • ermanent, Washable Aluminum Filter P 19-inch Rack Mountable Brushed Aluminum or Stainless Steel Grilles Performance Data Filter Grille Panel CATALOG NUMBERS Stainless Steel Aluminum UNIT CONSTRUCTION Height PMax (in./mm) Width (in./mm) Weight (lb./kg) 35G19 35H19 525G19 525H19 7G19 7H19 875G19 875H19 105G19 105H19 3.5/89 19/483 2/1.0 5.25/133 19/483 3/1.4 7.00/178 19/483 5/2.2 8.75/222 19/483 5/2.2 10.50/267 19/483 5/2.2 17.15 [436] 18.00 [457] 19.00 [483] 1.05 [27] .32 [8] 89081845 290 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION LOUVER PLATE KITS Designed to provide ventilation in enclosures where excessive internal heat or excessive moisture is a problem. Although louvers cannot keep all moisture out of an enclosure, gasketing or sealing the perimeter of the louver plate reduces problems associated with moisture intrusion. These kits may be easily installed in the field by making a cutout of the proper size and attaching the louver plate in place. Louver plates are made from 14 gauge steel with an ANSI 61 gray polyester powder finish over pretreated surfaces or 316 stainless steel. Hardware is furnished for mounting. Custom sizes, materials, finishes, etc., can be provided on special order. Design Data Louver Plate Kits CATALOG NUMBERS AVK23 AVK23SS6 AVK33 AVK33SS6 AVK34 AVK34SS6 AVK43 AVK43SS6 AVK44 AVK44SS6 AVK64 AVK64SS6 AVK66 AVK66SS6 AVK84 AVK84SS6 AVK86 AVK86SS6 AVK88 AVK88SS6 AVK812 AVK812SS6 Dimensions AxB in./mm 3.25 x 3.25/83 x 83 3.25 x 3.25/83 x 83 3.88 x 4.50/98 x 114 3.88 x 4.50/98 x 114 4.75 x 4.50/121 x 114 4.75 x 4.50/121 x 114 4.50 x 5.50/114 x 140 4.50 x 5.50/114 x 140 5.62 x 5.50/143 x 140 5.62 x 5.50/143 x 140 5.62 x 7.50/143 x 191 5.62 x 7.50/143 x 191 7.88 x 7.50/200 x 191 7.88 x 7.50/200 x 191 5.81 x 9.50/148 x 241 5.81 x 9.50/148 x 241 8.19 x 9.50/208 x 241 8.19 x 9.50/208 x 241 10.56 x 9.50/268 x 241 10.56 x 9.50/268 x 241 15.31 x 9.50/389 x 241 15.31 x 9.50/389 x 241 Number of Louvers 3 3 3 3 4 4 3 3 4 4 4 4 6 6 4 4 6 6 8 8 12 12 Thickness in./mm 0.19/5 0.19/5 0.25/6 0.25/6 0.25/6 0.25/6 0.25/6 0.25/6 0.25/6 0.25/6 0.31/8 0.31/8 0.31/8 0.31/8 0.31/8 0.31/8 0.31/8 0.31/8 0.31/8 0.31/8 0.31/8 0.31/8 Length L in./mm 2.00/51 2.00/51 3.00/76 3.00/76 3.00/76 3.00/76 4.00/102 4.00/102 4.00/102 4.00/102 6.00/152 6.00/152 6.00/152 6.00/152 8.00/203 8.00/203 8.00/203 8.00/203 8.00/203 8.00/203 8.00/203 8.00/203 Opening Area in. 2 /cm2 .86/5.54 .86/5.54 1.32/8.52 1.32/8.52 1.76/11.35 1.76/11.35 1.88/12.10 1.88/12.10 2.50/16.13 2.50/16.13 5.21/33.61 5.21/33.61 7.82/50.45 7.82/50.45 8.08/52.12 8.08/52.12 12.11/78.13 12.11/78.13 16.15/104.19 16.15/104.19 24.22/156.26 24.22/156.26 Cutout Size, F in./mm 2.00/51 2.00/51 2.62/67 2.62/67 3.50/89 3.50/89 3.25/83 3.25/83 4.38/111 4.38/111 4.38/111 4.38/111 6.62/168 6.62/168 4.56/116 4.56/116 6.94/176 6.94/176 9.31/236 9.31/236 14.06/357 14.06/357 Cutout Size, G in./mm 1.75/44 1.75/44 3.00/76 3.00/76 3.00/76 3.00/76 4.00/102 4.00/102 4.00/102 4.00/102 6.00/152 6.00/152 6.00/152 6.00/152 8.00/203 8.00/203 8.00/203 8.00/203 8.00/203 8.00/203 8.00/203 8.00/203 4 Catalog numbers ending in SS6 indicates 316L stainless steel LOUVER PLATE KIT FILTERS Filter Media Filter media is composed of layers of slit and expanded aluminum providing hundreds of adhesive coated baffle surfaces for trapping impurities. Impurities are held throughout the depth of the filter. Washing with warm water will keep the filter clean. To achieve best results, Filter Adhesive is recommended. Design Designed for use with Louver Plate Kit. Mounting holes on filter bracket align with louver mounting holes. Hardware supplied with louvers also secures filter brackets in place. Aluminum air filters provide good arrestment of airborne dust and dirt. EQUIPMENT PROTECTION CATALOG NUMBERS AFLT33 AFLT34 AFLT43 AFLT44 AFLT64 AFLT66 AFLT84 AFLT86 AFLT88 AFLT812 Dimensions H x W (in./mm) 3.22x 3.25/82 x 83 4.09 x 3.25/104 x 83 3.84 x 4.25/98 x 108 4.97 x 4.25/126 x 108 4.45 x 6.25/113 x 159 6.72 x 6.25/171 x 159 4.64 x 8.25/118 x 210 7.02 x 8.25/178 x 210 9.39 x 8.25/239 x 210 14.14 x 8.25/359 x 210 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Use with Steel Louver AVK33 AVK34 AVK43 AVK44 AVK64 AVK66 AVK84 AVK86 AVK88 AVK812 Use with Stainless Steel Louver AVK33SS6 AVK34SS6 AVK43SS6 AVK44SS6 AVK64SS6 AVK66SS6 AVK84SS6 AVK86SS6 AVK88SS6 AVK812SS6 Cooling 291 Fresh Air Enclosure Cooling Accessories 4 Fresh Air Enclosure Cooling Accessories VENT KIT CATALOG NUMBERS UNIT CONSTRUCTON Dimension H x W x D (in./mm) Color XPV32 PPV32B 11.81 x 7.88 x 1.03 300 x 200 x 26 Gray 11.81 x 7.88 x 1.03 300 x 200 x 26 Black Includes a stylized louvered cover and filter package. Use as an air inlet when a cooling fan is mounted in an enclosure or use two vent kits to allow passive airflow. Mounting hardware included. Vent Kit requires cutout shown in diagram. Available in gray (RAL 7042) or black. VENTILATOR CATALOG NUMBERS DESIGN DATA Description ANMV6 ANMV3 Large nonmetallic vent Small nonmetallic vent Designed to fit most metallic and non-metallic enclosures. Proper installation will provide rainproof ventilation but will not meet Type 4 or 12 requirements. Kit includes mounting hardware, and instructions. Supplied screws are 13-mm (.515-inch) long. Some applications may require longer screws. 292 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION FILTER ADHESIVE Designed to maximize the efficiency of all expanded aluminum air filters. Use of Filter Adhesive doubles the dust-retention capacity of the filter. Adhesive contains a low-viscosity water-soluble oil which absorbs dirt particles trapped on the surface of the filter. Through the circulation of the oil, a renewed impurity-absorbing surface is constantly established. Washing with water will remove dust, dirt and other impurities. Once the filter is dry, re-coat with adhesive. CATALOG NUMBERS DESIGN DATA Description AFLTAD Spray Adhesive 4 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 293 Fresh Air Enclosure Cooling Accessories COOLING ACCESSORIES 5 763.422.2211 763.576.3200 Intro Page CHAPTER 5 ACCESSORIES FEATURED PRODUCTS H2OMIT™ VENT DRAINS UL-approved vent drains allow accumulated water to drain out the bottom of an enclosure, while also functioning as an air pressure equalizer to prevent water and moisture from being pulled into the enclosure. Installs in the bottom of mild steel, aluminum, stainless steel or non-metallic enclosures. H2OMIT™ THERMOELECTRIC DEHUMIDIFIER Thermoelectric dehumidifiers remove moisture from the air within an enclosure and standing liquids, providing a cost-effective way to protect sensitive electronics from condensation. A built-in drain provision with plastic hose directs collected moisture to the vent drain (sold separately). 294 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION CHAPTER CONTENTS Intro Page CONDENSATION MANAGEMENT H2OMIT™ Vent Drains. . . . . . . . . . . . . . . . . . . . . . . . . . . 296 H2OMIT™ Thermoelectric Dehumidifier. . . . . . . . . . . . . 298 ENCLOSURE HEATERS Touch-Safe Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . Semiconductor Heaters . . . . . . . . . . . . . . . . . . . . . . . . . Electric Heaters. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Hazardous Location Heater. . . . . . . . . . . . . . . . . . . . . . . 300 301 303 307 CONTROLLERS Thermostat Controller . . . . . . . . . . . . . . . . . . . . . . . . . . Dual Thermostat. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electronic Hygrotherm. . . . . . . . . . . . . . . . . . . . . . . . . . Mechanical Hygrostat. . . . . . . . . . . . . . . . . . . . . . . . . . . Temperature Control Switch. . . . . . . . . . . . . . . . . . . . . . Panel-Mount Fan Speed Controls. . . . . . . . . . . . . . . . . . Hazardous Location Thermostat. . . . . . . . . . . . . . . . . . . 308 309 310 311 312 313 314 PRESSURE COMPENSATION Stainless Steel Pressure Compensation. . . . . . . . . . . . . 316 Pressure Compensation. . . . . . . . . . . . . . . . . . . . . . . . . 317 ENCLOSURE HEATERS Protect electronic, pneumatic, hydraulic and mechanical equipment from low temperatures, condensation and corrosion with Enclosure Heaters. To accommodate diverse applications, semiconductor, electric and hazardous locations are available. 5 DUAL THERMOSTAT With two thermostats in one unit, the Dual Thermostat independently controls equipment heating and cooling systems. Temperatures range from 32 to 140 degrees Fahrenheit. EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 295 5 Accessories Condensation Management H2OMIT™ VENT DRAINS CONDENSATION MANAGEMENT INDUSTRY STANDARDS Maintains UL/cUL Type 4, 4X rating when properly installed on a UL/cUL Type 4 or 4X enclosure. UL 508A Listed; Type 4, 4X; File No. E61997 cUL Listed per CSA C22.2 No 94; Type 4, 4X; File No. E61997 NEMA/EEMAC Type 4, 4X IEC 60529, IP66 FEATURES • • • • • APPLICATION H2OMIT™ Vent Drains allow accumulated water to drain out the bottom of an enclosure. The UL-approved vent drains also function as an air pressure equalizer, reducing the harmful effects of temperature-induced vacuums that could pull water and moisture into the enclosure. • ses gravity to remove collected liquids U One-way mechanical shut-off when pressure is equalized prevents water and contaminants from entering the enclosure Helps reduce corrosion that can limit the life of internal electrical and electronic components Installs in a 7/8-in. hole in the bottom of enclosure with provided nut or in a 1/2-in. NPT/NPS threaded conduit hub Installs in the bottom of mild steel, aluminum, stainless steel or non-metallic enclosures Maintains enclosure’s UL Type rating when properly installed SPECIFICATIONS Stainless Steel Vent Drain • C orrosion-resistant polyester material with a Type 304 stainless steel sleeve • 2 .00-in. long x 1.38-in outside diameter Non-Metallic Drain Vent • C orrosion-resistant polyester material • 2 .00-in. long x 1.25-in. outside diameter Performance Data H2OMIT Vent Drains CATALOG NUMBERS UNIT CONSTRUCTION Description D (in./mm) Quantity 296 Cooling AVDR4NM AVDR4SS4 Non-metallic Vent Drain 1.25/32 1 Stainless Steel Vent Drain 1.38/35 1 SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION +20,79HQW'UDLQV ' LQ137136 PP PP 5 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 297 Accessories Condensation Management 5 Accessories Condensation Management H2OMIT™ THERMOELECTRIC DEHUMIDIFIER INDUSTRY STANDARDS SPECIFICATIONS UL 508A Listed; File No. E61997 cUL Listed per C22.2 No. 14; File No. E61997 CE APPLICATION The H2OMIT™ Thermoelectric Dehumidifier removes moisture from the air within an enclosure, providing an inexpensive yet highly effective way to protect electronic and electrical components from condensation. • • • • • • • FEATURES • • • • • • educes corrosion that can limit the life of internal electrical and R electronic components Condenses moisture from internal enclosure air and standing liquids Built-in drain provision with plastic hose directs collected moisture to the Vent Drain (sold separately) Rotating side air vents direct recirculating air away from critical controls Mounts via DIN rail on internal panel or mounts directly onto the inside bottom of enclosure above the Vent Drain (sold separately) C an be used in mild steel, aluminum, stainless steel and nonmetallic enclosures 298 Cooling igh-impact ABS shell H Operates on 24-Volt DC power 4 .5 A max. (84 W) Runs continuously above 32 Fa (power supply not included) Removes 8 oz. of moisture in 24 hours Compact 6.00-in. x 5.50-in. x 5.75-in. design One Thermoelectric Dehumidifier includes: - Four feet of plastic hose - Two hose retainers - One double-ended hose retainer - Six inches of Velcro ® - Seven-inch strip of DIN rail - Two mounting screws Must be used with UL-certified drain to remove pooled liquid from enclosure. If continual operation is not desired, a Mechanical Hygrostat (AMHUM) can be wired to the thermoelectric dehumidifier and then set to turn the dehumidifier on at the desired relative humidity. a VELCRO is a trademark of Velcro Industries B.V. SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Performance Data H2OMIT Thermoelectric Dehumidifier CATALOG NUMBERS H2OMITTER Dew Point Temperature : Percent Relative Humidity Temp. (° F) 100% 95% 90% 85% 80% 110 110 108 106 104 102 105 105 103 101 99 97 100 100 99 97 95 93 95 95 96 92 90 88 90 90 88 87 85 83 85 85 83 81 80 78 80 80 78 77 75 73 75 75 73 72 70 68 70 70 68 67 65 63 65 65 63 62 60 59 60 60 58 57 55 53 55 55 53 52 50 49 50 50 48 46 45 44 45 45 43 42 40 39 40 40 39 37 35 34 35 35 34 32 — — 32 32 — — — — 75% 100 95 91 86 81 76 71 66 61 57 52 47 42 37 32 — — 70% 98 93 89 87 79 74 69 64 59 55 50 45 40 35 — — — 65% 95 91 86 81 79 71 67 62 58 53 48 43 38 34 — — — 60% 93 88 84 79 74 69 65 60 55 50 45 40 36 32 — — — 55% 90 85 81 76 71 67 62 58 53 48 43 38 34 — — — — 50% 87 83 78 73 68 64 59 55 50 45 41 36 32 — — — — 45% 84 80 75 70 65 61 56 52 47 42 38 33 — — — — — 40% 80 76 71 67 62 58 53 49 44 40 35 32 — — — — — 35% 76 72 67 63 59 54 50 45 40 36 32 — — — — — — 30% 72 67 63 59 54 50 45 41 37 62 — — — — — — — 25% 65 62 58 54 49 45 40 36 32 — — — — — — — — 20% 60 55 52 48 43 38 35 32 — — — — — — — — — 15% 51 47 44 40 36 32 32 — — — — — — — — — — 10% 41 37 32 32 32 — — — — — — — — — — — Definition: Dew Point is the temperature at which condensation forms. If the temperature of the enclosure is 85 F and the relative humidity is 80 percent, Dew Point is reached at a temperature of 78 F or below. This means that moisture vapor will condense on any surface that is below the Dew Point temperature of 78 F. 5 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 299 Accessories Condensation Management 5 Accessories Enclosure Heaters TOUCH-SAFE HEATERS ENCLOSURE HEATERS INDUSTRY STANDARDS cURus Component Recognized; File No. E150057 IP 20 CE APPLICATION Protect electronic, mechanical equipment from low temperatures, condensation, and corrosion with this heater, which will maintain stable enclosure temperatures by using natural convection resulting in current circulation of warm air. SPECIFICATIONS • • • • eating element PTC resistor - temperature limiting H Double Insulated Protection Mounting clip for 35mm DIN rail, EN 60 715 Vertical mount FINISH • UL 94 V-0 Black Plastic Housing Performance Data CATALOG NUMBERS Electrical Data Rated Voltage (AC/DC) Power Consumption (Watts) Start Nominal Current (Amps) Unit Construction H x W x D (in./mm) Weight (oz) 300 Cooling DAH101TS DAH201TS DAH501TS 110/120 10 2.5 110/120 20 4.5 110/120 50 8 3.9 X 1.5 X 3.0/98 x 38 x 75 5.0 3.9 X 1.5 X 3.0/98 x 38 x 75 6.1 4.3 X 2.4 X 3.5/110 x 60 x 90 10.4 SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION SEMICONDUCTOR HEATERS INDUSTRY STANDARDS SPECIFICATIONS • • cURus Component Recognized; File No. E150057 IEC IP54 CE TC (Positive Temperature Coefficient) heating element P Mounting clip for 35-mm DIN rails EN 50022 FINISH • APPLICATION Black anodized, extruded aluminum. Protect electronic, pneumatic, hydraulic and mechanical equipment from low temperatures, condensation and corrosion with this heater, which maintains a stable enclosure temperature. Performance Data Semiconductor Heater CATALOG NUMBERS ELECTRICAL DATA Rated Voltage Power Consumption (Watts) Start Nominal Current (Amps) HEATING PERFORMANCE Watts UNIT CONSTRUCTION L (in./mm) Weight (lb./kg) DAH101 DAH301 DAH601 AC/DC 110/120 10 0.8 AC/DC 110/120 30 1.2 AC/DC 110/250 60 2.5 10 30 60 1.97/50 0.45/0.20 3.93/100 0.66/0.30 5.5/140 1.10/0.50 5 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 301 Accessories Enclosure Heaters 5 Accessories Enclosure Heaters 302 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION ELECTRIC HEATERS 115/230 Volt 100/200 Watt 115/230 Volt 400/800 Watt 115/230 Volt 1300 Watt INDUSTRY STANDARDS UL 508A Component Recognized; File No. E61997 CSA Certified, CSA File No. LR42186 CE APPLICATION Protect mechanical, electrical and electronic equipment from low temperatures, condensation and corrosion with this thermostatically controlled, fan-driven heater that maintains a stable enclosure temperature. Fan draws cool air from the bottom of the enclosure and passes this air across the thermostat and heating element before being released into enclosure cavity. Heated air is discharged through the top of the heater unit. SPECIFICATIONS • • • • • Aluminum housing T hermostat range adjustable from 0 F to 100 F (-18 C to 38 C) Four 10-32 x self-tapping screws are included with each heater Ball bearing fan Terminal strip with clamp connector that accepts both solid and stranded wire CAUTION These electric heaters are not designed for use in dusty, dirty, corrosive, or hazardous locations. Portions of the heater can get hot. Adequate protection must be taken to protect people from potential burns, and to protect other components from this heat. Pentair Technical Products recommends this heater only be installed in a totally-enclosed metal enclosure. DO NOT INSTALL HEATERS ON WOOD PANELS. Heat sensitive components should not be placed near the heater discharge area since this air can be quite warm. The clearance range defines the space that must be kept free of these components for proper and safe operation of the heater. FINISH • Brushed aluminum EQUIPMENT PROTECTION 5 PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 303 Accessories Enclosure Heaters 5 Accessories Enclosure Heaters Performance Data 100 and 200 Watt Heaters CATALOG NUMBERS ELECTRICAL DATA Rated Voltage Frequency (Hz) Power Consumption (Watts) Nominal Current (Amps) HEATING PERFORMANCE Watts UNIT CONSTRUCTION Weight (lb./kg) X (in./mm) DAH1001A DAH1002A DAH2001A DAH2002A 115 50/60 100 0.98 230 50/60 100 0.49 115 50/60 200 1.89 230 50/60 200 0.95 100 100 200 200 1.6/0.73 4.00/102 1.6/0.73 4.00/102 1.6/0.73 4.00/102 1.6/0.73 4.00/102 DAH4001B DAH4002B DAH8001B DAH8002B 115 50/60 400 3.72 230 50/60 400 1.86 115 50/60 800 7.37 230 50/60 800 3.69 400 400 800 800 2.2/1.00 6.00/152 2.2/1.00 6.00/152 2.2/1.00 8.00/203 2.2/1.00 8.00/203 Performance Data 400 and 800 Watt Heaters CATALOG NUMBERS ELECTRICAL DATA Rated Voltage Frequency (Hz) Power Consumption (Watts) Nominal Current (Amps) HEATING PERFORMANCE Watts UNIT CONSTRUCTION Weight (lb./kg) X (in./mm) Performance Data 1300 Watt Heaters CATALOG NUMBERS ELECTRICAL DATA Rated Voltage Frequency (Hz) Power Consumption (Watts) Nominal Current (Amps) HEATING PERFORMANCE Watts UNIT CONSTRUCTION Weight (lb./kg) X (in./mm) 304 Cooling DAH13001C DAH13002C 115 50/60 1300 11.5 230 50/60 1300 5.7 1300 1300 3.4/1.54 8.00/203 3.4/1.54 8.00/203 SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION 5 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 305 Accessories Enclosure Heaters 5 Accessories Enclosure Heaters 'LPHQVLRQVDQG&OHDUDQFH5DQJH'UDZLQJIRU'$+&DQG'$+& ; ; 7(50,1$/675,3:,7+ &/$03&211(&725 ; '5,//; 7$325 86(6(/)7$33,1* 6&5(:63529,'(' 306 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION HAZARDOUS LOCATION HEATER INDUSTRY STANDARDS FEATURES APPLICATION • • • • • • • CE Conformity Certificate LCIE (Laboratoire Central des Industries Electriques) LCIE 01 ATEX 6073 EEx d IIC T4/II 2 GD, IP6x T135°C IEC 60529, IP65/I (grounded) Designed for use in hazardous locations where electronic components require protection from condensation and corrosion, sudden temperature drops and low temperatures. Maintenance-free High-performance heating cartridge (element) L arge convection surface E xtruded aluminum heat sink DIN clip for mounting Connection cable: Si HF-JZ 3 x AWG 18 x 3.3 ft. (0.75 mm² x 1 m) Operating voltage 110-120 VAC FINISH • Black anodized Performance Data Hazardous Location Heater CATALOG NUMBERS HLHEAT100 DESIGN DATA Heating Power (Watts) Surface Temperature T4 (°F/°C) * UNIT CONSTRUCTION Unit Dimensions - H x W x D (in. / mm) 100 275/135 7.10/180 x 4.65/118 x 270/69 * Surface temperature when mounted vertically. 5 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 307 Accessories Enclosure Heaters 5 Accessories Controllers THERMOSTAT CONTROLLER CONTROLLERS FEATURES • • • aves energy, reduces filter replacement frequency and extends S filter fan life Terminal block connection 3 8-mm DIN rail mounting bracket (according to EN 60715) and screws included FINISH • • AL7035 light gray R Plastic housing UL94 V-0 NOTES Caution: When setting the temperature of the break contact (NC) and the changeover contact (CO) to use it as a break contact, care must be taken to add the maximum hysteresis (that consists of the switching difference and the operating tolerance) to the required minimum temperature. For instance, if the temperature in the enclosure may not fall below 5 C, the controller must be set to 5+7+3=15 C (with a switching) difference of 4-7 k and tolerance of +/- 3 k. Performance Data Thermostat Controller CATALOG NUMBERS TWR60 DESIGN DATA Control Range (°F / °C) -4 / -20 to 104 / 40 or 32 / 0 to 140 / 60 or 68 / 20 to 176 / 80 (see type plate) Switching Differences: Bimetal controllers Capillary controllers Contact Approx. 1 k, approx. 3 k, 4-7 k (see type plate) less than 7 k Snap contact as break contact = NC Make contact = NO Changeover contact = CO (see type plate) Switching Capacity: Break contact/make contact Changeover contact - heating Changeover contact - cooling Supply Voltage Protection Switchpoint Tolerance Sensor Power Connection Bimetal Controller Ambient Temperature: T40 T60 T80 Storage Temperature (°F / °C) UNIT CONSTRUCTION Unit Dimensions - H x W x D (in. / mm) Weight (oz / g) 308 Cooling 100V…250V / 10(2)A, at 4 max. 30 W 100V…250V / 10(2)A, at 4 max. 30 W 100V…250V / 15(2)A, at 4 max. 30 W Controller (CO) requires 230V IP20 +/- 3k Bimetal Terminal screws 0.5 to 2.5 mm2 -4 / -20 to 104 / 40 32 / 0 to 140 / 60 68 / 20 to 176 / 80 -4 / -20 to 140 / 60 2.52 x 1.46 x 1.81 / 64 x 37 x 46 1.8 / 50 SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION DUAL THERMOSTAT INDUSTRY STANDARDS cURus; File No. E164102 CSA File No. 215952 CE APPLICATION Two thermostats in one, the Dual Thermostat independently controls equipment heating and cooling systems. FEATURES • • • • • wo thermostats; one normally closed (NC), red, and one T normally open (NO), blue, in one casing W ide adjustable temperature range (32 -140 F) Thermostatic bimetallic sensor element Connection: 4-pole terminal for AWG 14 max (2.5 mm2) Mounting clip for 35-mm DIN rail FINISH • Light-gray plastic, UL94V-0 Performance Data Dual Thermostat CATALOG NUMBERS ELECTRICAL DATA Switching Capacity (Normally Closed) Switching Capacity - Normally Open Setting Range - Normally Closed (°F/C°) Setting Range - Normally Open (°F/C°) UNIT CONSTRUCTION Unit Dimensions - H x W x D (in./mm) ADLTEMP 10 A resistive/2 A inductive @250 VAC, DC 30 W 5 A resistive/2 A inductive @250 VAC, DC 30 W 32/0 to 140/60 32/0 to 140/60 2.64/67 x 1.97/50 x 1.81/46 5 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 309 Accessories Controllers 5 Accessories Controllers ELECTRONIC HYGROTHERM APPLICATION The Electronic Hygrotherm senses ambient temperature and relative air humidity and adjusts a connected device to maintain temperature and humidity set points. FEATURES • • • • • • • • • emperature (32-140 F) and humidity (50%-90% RH) adjustment T High switching capacity Optical function displays (LED) in each control Mounting clip for 35-mm DIN rail Change-over contact (relay) Connection: 5-pole terminal for AWG 14 max (2.5-mm square). Clamping torque .5 Nm (4.4 in-lbs) maximum. Plastic housing UL94V-0 Vertical mounting Operating voltage is AC 100-240 V with maximum switching capacity of 10 A resistive / 1.6 A inductive at AC 240 V FINISH • Light-gray plastic UL94V-0 INDUSTRY STANDARDS cURus; File No. E164102 CE Performance Data Electronic Hygrotherm CATALOG NUMBERS ATEMHUM ELECTRICAL DATA Hysteresis Humidity Set Point (adjustable) Temperature Set Point (adjustable) (°F/°C) Operating Temperature Range (°F/°C) Storage Temperature (°F/°C) CONTACTS 3 and 5 Close at... Open at... Use for... 4 and 5 Close at... Open at... Use for... UNIT CONSTRUCTION Unit Dimensions - H x W x D (in./mm) 310 Cooling ~ 3.6 F (2K) ± 1.8 F (1K) tolerance 50-90% RH 32/0 to 140/60 -40 to 140/-40 to 60 -40 to 140/-40 to 60 humidity rise or temperature drop humidity drop or temperature rise heaters, dehumidifiers, low-temp alarms humidity drop or temperature rise humidity rise or temperature drop cooling, humidifiers, high-temp alarms 3.03/77 x 2.36/60 x 1.69/43 SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION MECHANICAL HYGROSTAT INDUSTRY STANDARDS cURus; File No. E164102 CE APPLICATION The Mechanical Hygrostat controls relative air humidity inside an enclosure to prevent condensation and corrosion that can damage components. It can also be connected to an enclosure heater, cooling fans, warning lights or other devices. The critical relative humidity (RH) level for most components is 65 percent. Above 65 percent RH, condensation can form and cause electronic equipment to malfunction. FEATURES • • • • • • • • • djustable relative humidity range A High switching capacity Long service life (>100,000 cycles) Maximum permissible air velocity of 50 ft./sec. (15 m/s) Maximum switching voltage = 250 VAC 250 V should be switched only in a non-condensing environment Change-over contact Mounting clip for 35-mm DIN rail Connection: 3-pole terminal for AWG 14 max. (2.5-mm squared) Contact resistance less than 10 mΩ FINISH • Light-gray plastic, UL94V-0 Performance Data Mechanical Hygrostat CATALOG NUMBERS ELECTRICAL DATA Switching Capacity (Minimum) Switching Capacity (Maximum) Operating Temperature Adjustable) (°F/°C) Storage Temperature (°F/°C) UNIT CONSTRUCTION Unit Dimensions - H x W x D (in./mm) Weight (oz/g) AMHUM 100mA @ AC/DC 20 V 5A @ AC 250 V (resistive load) 0.2A @ AC 250 V (inductive load at cos O = 0.8) DC 20W 32/0 to 140/60 -40/-40 to 140/60 2.64/67 x 1.97/50 x 1.5/38 2/60 5 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 311 Accessories Controllers 5 Accessories Controllers TEMPERATURE CONTROL SWITCH FEATURES • • • • • dditional label for conversion to Celsius scale and blank label to A cover set point range label when adjustment after initial setting is not desired are included Bimetal temperature sensor Plastic housing Connections consist of tubular screw terminals for AWG 14 (.04 sq. in.) Provision for both panel mounting and DIN rail mounting FINISH • Molded plastic housing is black INDUSTRY STANDARDS cURus; File No. E164102 UL94-VO Protection rating IEC IP30 CSA Certified, File Number 215952 CE APPLICATION These easy-to-install thermostats regulate and monitor air temperature in enclosures that contain heat-emitting equipment. Thermostats prolong heater and fan life expectancy by controlling operation time and increase electrical component working efficiency by exposing them to fewer environmental contaminants. Performance Data Temperature Control Switch CATALOG NUMBERS ELECTRICAL DATA Maximum Load (Switching Capacity) 120 VAC 250 VAC DC Minimum load Contact Type Control Application UNIT CONSTRUCTION Unit Dimensions - H x W x D (in./mm) 312 Cooling ATEMNC ATEMNO 15 A resistive / 2 A inductive @ 120 VAC 10 A resistive / 2 A inductive @ 250 VAC DC 30 W 20 mA (all voltages) NC (normally closed), quick acting NO (normally open), quick acting Heater Fan 2.37/60 x 1.31/33 x 1.55/39 SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION PANEL-MOUNT FAN SPEED CONTROLS APPLICATION Perfect for offices, classrooms and other noise-sensitive areas. Fan Speed Control optimizes airflow in a cabinet or rack, balancing air volume requirements with noise level and power use. FEATURES • • • • • • • INDUSTRY STANDARDS • UL 508 Listed; File No. E249700 cUL Listed per CSA C22.2 No. 14; File No. E249700 • utomatically adjusts fan speed depending on remote A temperature sensor input Temperature set point is field adjustable; preset at 35 C (95 F) Idle speed and temperature slope are field-adjustable Push-to-reset thermal circuit breaker inside control housing Compact polycarbonate control housing can be mounted in any position NEMA 5-15R outlet provides power to fan Six-foot (1.83-m) power cord plugs into standard 120 V, 50 or 60 Hz outlet Remote temperature sensor with 10-ft. (3.05-m) lead mounts in airflow Mounting brackets included FINISH • A FANTSC: Light-gray polycarbonate control housing Performance Data Panel-Mount Fan Speed Controls CATALOG NUMBERS AFANTSC ELECTRICAL DATA Rated Voltage Maximum Nominal Current (Amps) Temperature Settings (°F) Temperature Settings (°C) DESIGN DATA Description 120 VAC 2 86, 95, 104, 113 30, 35, 40, 45 Panel-Mount Fan Speed Control Fan speed controlled automatically with remote temperature sensor Application 20 49 08 89 5 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 313 Accessories Controllers 5 Accessories Controllers HAZARDOUS LOCATION THERMOSTAT APPLICATION Compact mechanical thermostat for temperature control of heaters or low-temperature alarms in enclosures that are used in explosion-hazardous areas. FEATURES INDUSTRY STANDARDS CE Conformity Certificate LCIE (Laboratoire Central des Industries Electriques) LCIE 01 ATEX 6074 EEx d IIC T6/II 2 GD, IP6x T85 °C IEC 60529, IP65/1 (grounded) • • • • • • • • • • Compact design S et temperature High switching capacity Small hysteresis (switching difference) Long service life (greater than 100,000 cycles) Can usually be connected directly and switched without the need for additional relays Thermostatic bimetallic sensor element One-pole contact opens with rising temperature Mounting bracket and DIN clip for mounting Connection cable: Si HF - JZ 3 x AWG 18 x 3.3 ft. (0.75 mm² x 1 m) FINISH • Black anodized aluminum Performance Data Hazardous Location Thermostat CATALOG NUMBERS DESIGN DATA Maximum Operating Voltage (AC) Maximum Operating Voltage (DC) Switching Capacity @ 250 VAC Switch Off (Open) Temperature (°F) Switch Off (Open) Temperature (°C) Switch On (Closed) Temperature below Switch Off Temperature (°F) Switch On (Closed) Temperature below Switch Off Temperature (°C) 314 Cooling SUBJECT TO CHANGE WITHOUT NOTICE HLTHERMNC 250 V 100 V 4A resistive; 1A ind. (cos f = 0.6) 77 +/- 6 25 +/- 3K 7.2 +/- 2 4 +/- 1K EQUIPMENT PROTECTION Notes 5 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 315 Accessories Controllers 5 Accessories Pressure Compensation STAINLESS STEEL PRESSURE COMPENSATION PRESSURE COMPENSATION SPECIFICATIONS • • • ype 316L stainless steel T S emipermeable membrane inside the plug filters moisture and dust Mounting thread M40 with union nut FINISH • Machined Type 316L stainless steel CATALOG NUMBERS UNIT CONSTRUCTION Operating/Storage Temperature (°F/°C) Unit Dimenstions (in./mm) Depth into Enclosure (in./mm) INDUSTRY STANDARDS CE NEMA Type 4X IEC/EN 60529, IP66 APCDSS6 -40/-40 to 176/80 2.28/58Ø x 1.22/31 .35/9 APPLICATION Pressure differentials in a tightly sealed enclosure result from heat generated by electrical and electronic equipment within the enclosure and fluctuations of outside ambient temperature. Stainless steel pressure compensation devices provide IP66 protection in corrosive applications requiring slow pressure equalization. For optimal performance, install two plugs diagonally to each other. FEATURES • • • ir permeability = 42 cubic feet/hour (1,200 liters/hour) at a A pressure difference of min. 70 mbar E asy installation: drill one 1.60-in. (41-mm) diameter hole S ealing gasket (Nitrile Buna-N Rubber) 316 Cooling SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION PRESSURE COMPENSATION SPECIFICATIONS • • • emipermeable membrane inside the plug to filter moisture and S dust Mounting thread M40 with union nut Plastic PA66 FINISH ight-gray plastic. Polymeric material manufactured by L DuPont™ . DuPont is the trademark of E. I. duPont de Nemours and Company. • CATALOG NUMBERS UNIT CONSTRUCTION Operating/Storage Temperature (°F/°C) Unit Dimensions (in./mm) Depth into Enclosure (in./mm) INDUSTRY STANDARDS UL Type 1, 4, 4X; File No. E234324 CE IEC/EN 60529, IP66 APCDABS -49/-45 to 158/70 2.36/60Ø x 146/37 .6/15 APPLICATION Pressure differentials in a tightly sealed enclosure result from heat generated by electrical and electronic equipment within the enclosure and fluctuations of outside ambient temperature. Pressure compensation devices provide IP66 protection in applications requiring slow pressure equalization. For optimal performance, install two plugs diagonally to each other. FEATURES • • • ir permeability = 42 cubic feet/hour (1,200 liters/hour) at a A pressure difference of min. 70 mbar E asy installation: drill one 1.60-in. (41-mm) diameter hole S ealing gasket (Nitrile Buna-N Rubber) 5 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • HOFFMANONLINE.COM Cooling 317 Accessories Pressure Compensation 6 Catalog Number Index Catalog Number Catalog Page INDEX INDEX Catalog Number Catalog Page 1EB52H115A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261 1EB52H115B. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261 1EB52H230A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261 1EB52H230B. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 261 1NB412115. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270 1NB412230. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 270 1RB100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268, 269 1RB100M . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268, 269 1RB120. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268, 269 1RB120M . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268, 269 1RB65. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268, 269 1RB65M. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268, 269 1RB80. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268, 269 1RB80M. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 268, 269 10100059H. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241 10100060. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241 10100061. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241 10100062. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241 10100063. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241 10100064H. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241 10100065H. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241 10100066H. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241 10100067H. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241 105G19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 290 105H19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 290 2EB17H115. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 257 2EB17H230. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 257 2EB300R115. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262 2EB300R230. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262 2EB3500R115. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262 2EB3500R230. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262 2EB412R115. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262 2EB412R230. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262 2EB512R115. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262 2EB512T115. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262 2EB612R115. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262 2EB612R230. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 262 2NB300XXX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272 2NB300115. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272 2NB300230. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272 2NB3500XXX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272 2NB3500115. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272 2NB3500230. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272 2NB412XXX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272 2NB412115. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272 2NB412230. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272 2NB424XXX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272 2NB424115. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272 2NB424230. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272 2NB512XXX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272 318 Index Catalog Page 2NB512115. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272 AB2501199901 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274 2NB512230. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 272 AB2502399901 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274 3EB17H115. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 257 AB280. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 275, 276 C Catalog Number Index Catalog Number 3EB17H230. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 257 AB2801193901 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274 330416GW010. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 AB2802393901 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274 330426GW012. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 AB320. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 275, 276 330426GW014. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133 AB3201116101 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274 35G19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 290 AB3202316101 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274 35H19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 290 AB355. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 275, 276 4EB300RT115 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 264 AB3551117101 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274 525G19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 290 AB3552317101 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274 525H19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 290 ABRKT10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255 7G19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 290 ABRKT2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255 7H19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 290 ABRKT3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255 875G19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 290 ABRKT4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255 875H19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 290 ABRKT6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255 A10AXFN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251, 252 ACORD1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 254 A10AXFN2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251, 252 ACORD2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 254 A10AXFNPG. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251, 252 ACORD2T. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 254 A19FANSC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 259 ADB275. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 266 A19FT3B. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 258 ADLTEMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 309 A19FT6B. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 258 AEXGR275. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 267 A2AXFN24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251 AFANTSC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 313 A3AXFN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251, 252 AFLT33. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 A3AXFN24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251, 252 AFLT34. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 A4AXFN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251, 252 AFLT43. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 A4AXFN2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251, 252 AFLT44. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 A4AXFN24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251, 252 AFLT64. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 A4AXFNGQ. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251, 252 AFLT66. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 A4AXFNPG. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251, 252 AFLT812 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 A6AXFN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251, 252 AFLT84. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 A6AXFN2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251, 252 AFLT86. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 A6AXFN24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251, 252 AFLT88. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 A6AXFNGQ. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251, 252 AFLTAD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 293 A6AXFNPG. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 251, 252 AFLTR10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246 AB133. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 275, 276 AFLTR10AL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246 AB1331196701 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274 AFLTR275AL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 267 AB1332396701 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274 AFLTR4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246 AB175. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 275, 276 AFLTR4AL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246 AB1751171701 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274 AFLTR4LD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 254 AB1752371701 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274 AFLTR6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246 AB190. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 275, 276 AFLTR6AL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246 AB1901169901 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274 AFLTR6LD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 254 AB1902369901 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274 AGARD10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255 AB220. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 275, 276 AGARD2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255 AB2201171901 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274 AGARD3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255 AB2202371901 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274 AGARD4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255 AB225. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 275, 276 AGARD6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255 AB2251110901 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274 AMHUM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 311 AB2252310901 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 274 ANMV3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292 AB250. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 275, 276 ANMV6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292 SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Catalog Page Catalog Number Catalog Page Catalog Number Catalog Page AOFF118. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 248 CR290226G030. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 CR430826GWXXX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137 APCDABS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 317 CR290226G031. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 CR430846G401. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 APCDSS6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 316 CR290226G037. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 DAH1001A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 304 ATEMHUM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 310 CR290226G041. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 DAH1002A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 304 ATEMNC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 312 CR290226G045. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 DAH101. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301 ATEMNO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 312 CR290226G046. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 DAH101TS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300 AVDR4NM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 296 CR290226G058. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 DAH13001C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 304 AVDR4SS4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 296 CR290246G400. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 DAH13002C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 304 AVK23. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 CR290246G401. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 DAH2001A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 304 AVK23SS6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 CR290416G002. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 DAH2002A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 304 AVK33. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 CR290416G030. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 DAH201TS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300 AVK33SS6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 CR290416G045. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 DAH301. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301 AVK34. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 CR290416G047. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 DAH4001B. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 304 AVK34SS6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 CR290416G052. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 DAH4002B. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 304 AVK43. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 CR290416G068. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 DAH501TS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300 AVK43SS6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 CR290426G002. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 DAH601. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301 AVK44. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 CR290426G017. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 DAH8001B. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 304 AVK44SS6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 CR290426G022. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 DAH8002B. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 304 AVK64. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 CR290426G027. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 DB102. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 284 AVK64SS6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 CR290426G054. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 DB102XX54. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 283 AVK66. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 CR290426G061. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 DB1021254401. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282 AVK66SS6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 CR290426G067. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 DB1022454401. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282 AVK812. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 CR290426G101. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 DB1024854401. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282 AVK812SS6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 CR290446G400. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 DB133. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 284 AVK84. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 CR430616G002. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 DB133XX42. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 283 AVK84SS6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 CR430616G004. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 DB133XX91. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 283 AVK86. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 CR430616G013. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 DB1331242401. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282 AVK86SS6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 CR430616G016. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 DB1332442401. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282 AVK88. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 CR430616G031. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 DB1332491701. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282 AVK88SS6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 291 CR430626G002. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 DB1334842401. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282 CR230216G002. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 CR430626G014. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 DB1334891701. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282 CR230216G007. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 CR430626G018. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 DB175. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 284 CR230216G013. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 CR430626G020. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 DB175XX55. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 283 CR230216G015. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 CR430626G030. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 DB175XX69. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 283 CR230216G016. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 CR430626G034. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 DB1752455701. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282 CR230216G017. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 CR430626G074. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 DB1752469701. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282 CR230226G002. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 CR430646G004. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 DB1754855701. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282 CR230226G009. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 CR430816G002. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 DB1754869701. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282 CR230226G014. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 CR430816G010. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 DB220. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 284 CR230226G016. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 CR430816G021. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 DB220XX71. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 283 CR230226G030. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 CR430816G023. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 DB2202471701. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282 CR230226G037. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 CR430816G036. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 DB2204871701. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282 CR230246G400. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123 CR430816G038. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 DCG2904248100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207 CR290216G002. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 CR430816GW010. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137 DCG4108548100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207 CR290216G013. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 CR430826G002. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 DCT3809448100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207 CR290216G030. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 CR430826G007. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 DCT5615048100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 207 CR290216G035. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 CR430826G024. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 G280416G050. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 CR290216G036. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 CR430826G026. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 G280416G051. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 CR290226G002. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 CR430826G037. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 G280416G060. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 CR290226G010. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 CR430826G038. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 G280416G100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 CR290226G020. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126 CR430826G089. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129 G280416G101. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • MCLEANCOOLINGTECH.COM Index 319 6 Catalog Number Catalog Number Index 6 Catalog Number Index Catalog Number Catalog Page Catalog Number Catalog Page Catalog Number Catalog Page G572046G151. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 G280416G102. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 G520826G101 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 G280416G150. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 G520826G102 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 H2OMITTER. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 299 G280416G151. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 G520826G150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 HB160816G040. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 G280426G050. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 G520826G151 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 HB160826G040. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 G280426G051. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 G520846G050 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 HB160846G040. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120 G280426G060. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 G520846G051 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 HLHEAT100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 307 G280426G100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 G520846G060 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 HLTHERMNC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 314 G280426G101. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 G520846G100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 LB110416GW008. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141 G280426G102. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 G520846G101 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 LB110426GW010. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141 G280426G150. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 G520846G102 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 MHB110216G306. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 G280426G151. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 G520846G150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 MHB110226G306. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 G280446G050. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 G520846G151 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 MHB110246G400. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117 G280446G051. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 G521216G050 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 MHB110416G307. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118 G280446G060. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 G521216G051 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 MHB110426G306. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118 G280446G100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 G521216G060 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 MHB110446G400. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118 G280446G101. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 G521216G100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 N170116G010. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 G280446G102. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 G521216G101 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 N170116G020. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 G280616G050. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 G521216G102 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 N170126G010. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 G280616G051. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 G521216G150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 N170126G020. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 G280616G060. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 G521216G151 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 N170146G010. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 G280616G100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 G521226G050 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 N170146G020. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 G280616G101. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 G521226G051 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 N170216G010. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 G280616G102. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 G521226G060 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 N170216G020. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 G280616G150. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 G521226G100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 N170226G010. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 G280616G151. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 G521226G101 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 N170226G020. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 G280626G050. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 G521226G102 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 N170246G010. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 G280626G051. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 G521226G150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 N170246G020. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71 G280626G060. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 G521226G151 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 N280416G050. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 G280626G100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 G521246G050 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 N280416G051. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 G280626G101. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 G521246G051 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 N280416G060. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 G280626G102. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 G521246G060 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 N280416G100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 G280626G150. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 G521246G100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 N280416G102. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 G280626G151. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 G521246G101 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 N280416G150. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 G280646G050. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 G521246G102 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 N280416G151. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 G280646G051. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 G521246G150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 N280425G050. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 G280646G060. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 G521246G151 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 N280425G051. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 G280646G100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 G572026G050 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 N280425G060. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 G280646G101. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 G572026G051 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 N280425G100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 G280646G102. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29 G572026G060 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 N280425G102. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 G520816G050. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 G572026G100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 N280425G150. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 G520816G051. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 G572026G101 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 N280425G151. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 G520816G060. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 G572026G102 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 N280426G050. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 G520816G100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 G572026G150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 N280426G051. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 G520816G101. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 G572026G151 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 N280426G060. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 G520816G102. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 G572046G050 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 N280426G100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 G520816G150. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 G572046G051 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 N280426G102. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 G520816G151. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 G572046G060 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 N280426G150. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 G520826G050. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 G572046G100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 N280426G151. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 G520826G051. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 G572046G101 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 N280446G050. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 G520826G060. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 G572046G102 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 N280446G051. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 G520826G100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 G572046G150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 N280446G060. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 320 Index SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Catalog Page Catalog Number Catalog Page Catalog Number Catalog Page N280446G100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 N431216G150. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 SF0916414. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218 N280446G102. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 N431216G151. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 SF0916513. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218 N280446G150. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 N431226G050. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 SF0916514. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218 N280446G151. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53 N431226G051. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 SF0924413. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218 N360616G050. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 N431226G060. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 SF0924414. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218 N360616G051. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 N431226G100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 SF0924513. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218 N360616G060. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 N431226G102. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 SF0924514. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218 N360616G100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 N431226G150. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 SF0926413. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218 N360616G102. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 N431226G151. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 SF0926414. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218 N360616G150. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 N431246G050. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 SF0926513. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218 N360616G151. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 N431246G051. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 SF0926514. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218 N360626G050. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 N431246G060. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 SF0948413. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218 N360626G051. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 N431246G100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 SF0948414. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218 N360626G060. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 N431246G102. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 SF0948513. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218 N360626G100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 N431246G150. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 SF0948514. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218 N360626G102. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 N431246G151. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 SF1016413. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220 N360626G150. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 PLHC52G57. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 SF1016414. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220 N360626G151. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 PLHC52T53. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 SF1016513. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220 N360646G050. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 PLM13N17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 SF1016514. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220 N360646G051. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 PLM28G28 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 SF1024413. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220 N360646G060. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 PLM28N17 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 SF1024414. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220 N360646G100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 PLM33N28 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 SF1024513. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220 N360646G102. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 PLM36N36 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 SF1024514. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220 N360646G150. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 PLM52G52 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 SF1026413. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220 N360646G151. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 PLT29G28. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79 SF1026414. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220 N360816G050. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 PPV32B. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292 SF1026513. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220 N360816G051. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 SF0416413. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213 SF1026514. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220 N360816G060. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 SF0416414. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213 SF1048413. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220 N360816G100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 SF0424413. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213 SF1048414. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220 N360816G102. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 SF0424414. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213 SF1048513. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220 N360816G150. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 SF0426413. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213 SF1048514. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 220 N360816G151. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 SF0426414. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213 SF1316413 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222 N360826G050. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 SF0448413. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213 SF1316413R. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222 N360826G051. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 SF0448414. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 213 SF1316414. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222 N360826G060. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 SF0516413. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216 SF1316414R. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222 N360826G100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 SF0516414. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216 SF1316423. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224 N360826G102. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 SF0516513. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216 SF1316423R. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226 N360826G150. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 SF0516514. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216 SF1316424. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224 N360826G151. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 SF0524413. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216 SF1316424R. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226 N360846G050. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 SF0524414. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216 SF1316433. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227 N360846G051. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 SF0524513. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216 SF1316433R. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 229 N360846G060. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 SF0524514. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216 SF1316434. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227 N360846G100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 SF0526413. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216 SF1316434R. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 229 N360846G102. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 SF0526414. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216 SF1316513. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222 N360846G150. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 SF0526513. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216 SF1316514. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222 N360846G151. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 SF0526514. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216 SF1316523. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224 N431216G050. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 SF0548413. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216 SF1316524. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224 N431216G051. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 SF0548414. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216 SF1316533. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227 N431216G060. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 SF0548513. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216 SF1316534. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227 N431216G100. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 SF0548514. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 216 SF1324413. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222 N431216G102. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65 SF0916413. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 218 SF1324414. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • MCLEANCOOLINGTECH.COM Index 321 6 Catalog Number Catalog Number Index 6 Catalog Number Index Catalog Number Catalog Page Catalog Number Catalog Page Catalog Number Catalog Page SF1324433. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227 SH10GS61001. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240 T200216G100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 SF1324434. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227 SH10SS04001. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240 T200216G150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 SF1324513. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222 SH13GS35001. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240 T200216G155 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 SF1324514. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222 SH13GS61001. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240 T200216G157 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 SF1324533. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227 SH13SS04001. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240 T200226G100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 SF1324534. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227 SR1616414. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236 T200226G103 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 SF1326413. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222 SR1616424. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 238 T200226G150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 SF1326413R. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222 SR1626414. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236 T200226G158 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 SF1326414. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222 SR1626424. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 238 T200246G400 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 SF1326414R. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222 ST1016413 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231 T200246G401 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84 SF1326423. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224 ST1016414 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231 T290416G100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 SF1326423R. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226 ST1016513 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231 T290416G150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 SF1326424. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224 ST1016514 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231 T290416G156 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 SF1326424R. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226 ST1024413 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231 T290416G159 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 SF1326433. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227 ST1024414 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231 T290426G100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 SF1326433R. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 229 ST1024513 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231 T290426G150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 SF1326434. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227 ST1024514 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231 T290426G160 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 SF1326434R. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 229 ST1026413 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231 T290426G161 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 SF1326513. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222 ST1026414 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231 T290446G400 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 SF1326514. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222 ST1026513 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231 T290446G403 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89 SF1326523. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224 ST1026514 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231 T4EMC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 247 SF1326524. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224 ST1048413 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231 T430616G100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 SF1326533. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227 ST1048414 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231 T430616G102 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 SF1326534. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227 ST1048513 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231 T430616G150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 SF1340423. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224 ST1048514 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 231 T430626G100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 SF1340423R. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226 ST1316413 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233 T430626G150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 SF1340424. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224 ST1316413R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233 T430626G159 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 SF1340424R. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 226 ST1316414 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233 T430646G153 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 SF1340434R. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 229 ST1316414R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233 T430646G400 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 92 SF1340523. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224 ST1316513 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233 T430816G100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 SF1340524. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 224 ST1316513R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233 T430816G150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 SF1346433. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227 ST1316514 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233 T430816G153 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 SF1346433R. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 229 ST1316514R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233 T430826G100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 SF1346434. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227 ST1326413 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233 T430826G108 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 SF1346533. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227 ST1326413R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233 T430826G150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 SF1346534. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227 ST1326414 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233 T430846G400 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 SF1348413. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222 ST1326414R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233 T430846G402 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 SF1348414. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222 ST1326513 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233 T430846G403 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94 SF1348433. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227 ST1326513R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233 T431016G100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 SF1348434. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227 ST1326514 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233 T431016G102 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 SF1348513. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222 ST1326514R . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 233 T431016G150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 SF1348514. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 222 T10EMC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 247 T431016G153 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 SF1348533. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227 T150116G100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 T431026G100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 SF1348534. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 227 T150116G120 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 T431026G104 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 SH05GS35001. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240 T150116G150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 T431026G150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 SH05GS61001. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240 T150116G151 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 T431026G152 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 SH05SS04001. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240 T150116G152 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 T431046G400 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 SH09GS35001. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240 T150126G100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 T431046G406 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 96 SH09GS61001. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240 T150126G104 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 T501226G100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 SH09SS04001. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240 T150126G120 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 T501226G125 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 SH10GS35001. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 240 T150126G150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81 T501226G150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 322 Index SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION Catalog Page Catalog Number Catalog Page Catalog Number Catalog Page T501226G156 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 TFP61SS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244 VC1516012. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195 T501246G400 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 TFP61UL12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244 VC1716004. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195 T501246G401 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99 TFP62. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244, 247 VC171604X. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195 T6EMC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 247 TFP62SS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244 VC2516004. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195 T622226G150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107 TFP62UL12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244 VC2516012. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195 T622246G400 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107 TFP624. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244 VC251604X. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195 T703626G150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110 TG10B. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246 VCOF17. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195, 201, 203 TG10SS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246 VCOF25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195, 201, 203 T706026G150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113 TG4B. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246 VHL09160. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202 T706046G400 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 113 TG4SS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246 VHL15160. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202 TE090624010 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185 TG6B. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246 VHL25160. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202 TE090624011 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185 TG6SS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246 VHL50160. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 202 TE090624020 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 185 TWR60 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 308 VHLDK. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 203 TE121024010 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187 TX231416100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161 WCHE01916002. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175 TE121024011 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187 TX231424100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161 WCHE01926002. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 175 TE121024020 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187 TX231426100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161 WCHE04916002. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177 TE121048010 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187 TX231448100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161 WCHE04926002. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 177 TE121048020 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 187 TX332816100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164 WCHE06916002. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179 TE162024010 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189 TX332824100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164 WCHE06926002. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 179 TE162024011 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189 TX332826100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164 WCHE14916002. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181 TE162024020 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189 TX332848100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 164 WCHE14926002. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 181 TE162048010 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189 TX385616100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167 XPV32. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 292 TE162048020 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 189 TX385624100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167 XR200416012. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145 TEC24VCNTLR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192 TX385626100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167 XR200426012. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145 TEC48VCNTLR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 192 TX385648100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167 XR290816012. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147 TEP10. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246, 247 TX528316100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170 XR290826012. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 147 TEP10SS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246 TX528324100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170 XR291816012. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149 TEP10UL12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246 TX528326100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170 XR291826012. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149 TEP4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246, 247 TX528348100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 170 XR472416012. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151 TEP4SS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246 UEB17H115. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 257 XR472426012. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 151 TEP4UL12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246 UEB17H230. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 257 XR473516012. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153 TEP6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246, 247 UEB17H24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 257 XR473526012 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 153 TEP6SS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246 VA0916012. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200 XR605516012. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155 TEP6UL12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246 VA091604X. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 199 XR605526012. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155 TFLT10UL12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246 VA1516012. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200 XR608416012. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157 TFLT4UL12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246 VA151604X. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 199 XR608426012. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157 TFLT6UL12 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246 VA2516012. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200 TFP101. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245, 247 VA251604X. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 199 TFP101SS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245 VA5016012. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 200 TFP101UL12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245 VA501604X. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 199 TFP102. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245, 247 VAAF15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201, 203 TFP102SS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245 VAAF25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201, 203 TFP102UL12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245 VAAF50. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201, 203 TFP41. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243, 247 VADK124X. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201 T703646G400 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110 TFP41SS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243 VAGK09. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201, 203 TFP41UL12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243 VAGK15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201, 203 TFP42. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243, 247 VAGK25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 201, 203 TFP42SS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243 VC0416012. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195 TFP42UL12. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243 VC0916004. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195 TFP424. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 243 VC0916012. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195 TFP61. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244, 247 VC091604X. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 195 EQUIPMENT PROTECTION PH 763.422.2211 • FAX 763.576.3200 • MCLEANCOOLINGTECH.COM 6 Index 323 Catalog Number Catalog Number Index 6 Product Index Product Description Catalog Page P Product Index 19-in. Rack-Mountable Tray................................................... 258 AC Motorized Impellers.......................................................... 274 Air Conditioner Cooling Capacity Overview................................. 8 Airflow................................................................................... 16 Airflow Design Options........................................................... 15 CE.......................................................................................... 22 Centrifugal Blowers............................................................... 270 Choosing an Air Mover............................................................ 16 CLIMAGUARD™ Air-to-Air Indoor............................................ 144 CLIMAGUARD™ Air-to-Air Outdoor.......................................... 160 CLIMAGUARD™ Air-to-Water Indoor....................................... 174 Compact Axial Fans............................................................... 250 Conductive Enclosure Cooling................................................... 5 DACS Outdoor........................................................................ 206 DC Motorized Impellers......................................................... 282 Determine Heat Exchanger Capacity........................................ 12 Determine Heat Transfer......................................................... 11 Determine Internal Heat Load................................................. 11 Determine Total Heat Load...................................................... 10 Dual Thermostat.................................................................... 309 Electric Heaters..................................................................... 303 Electronic Hygrotherm........................................................... 310 Enclosure Protection.............................................................. 16 Equation Method.................................................................... 10 Exhaust Grilles and Replacement Filters................................ 267 Fan Brackets......................................................................... 255 Fan Cords.............................................................................. 254 Fan Cords With Inline Thermostat.......................................... 254 Fan Filter and Finger Guard Kit.............................................. 254 Filter Adhesive...................................................................... 293 Filter Box Fans...................................................................... 268 Filter Fan Shrouds................................................................. 240 Filter Grille Panel.................................................................. 290 Finger Guards........................................................................ 255 Fresh Air Enclosure Cooling...................................................... 5 Friendly Reminder.................................................................. 19 GENESIS™ Top-Mount Indoor................................................. 116 GOST...................................................................................... 22 H2OMIT™ Thermoelectric Dehumidifier.................................. 298 H2OMIT™ Vent Drains............................................................ 296 Hazardous Location Heater.................................................... 307 Hazardous Location Thermostat............................................. 314 Heat Exchanger Cooling Capacity Overview.............................. 11 Heat Ruins Electronics............................................................. 4 How is Performance Characterized?........................................ 14 Introduction........................................................................ 7, 13 Louver Plate Kit Filters.......................................................... 291 Louver Plate Kits................................................................... 291 Product Description Catalog Page Product Description Catalog Page Panel-Mount Fan Speed Controls........................................... 313 Water-Cooled Indoor.............................................................. 132 Part A: Determine Internal Heat Load........................................ 8 Water-Cooled Indoor/Outdoor................................................ 136 Part B: Determining Heat Transfer Load Overview...................... 9 Water-Cooled Rack-Mount..................................................... 140 Power Input............................................................................ 16 What Are the Capabilities of Each Air Mover?.......................... 14 Pressure Compensation......................................................... 317 What Is Airflow?..................................................................... 13 PROAIR Harsh Environment.................................................... 122 What Is Static Pressure?........................................................ 13 Protection Levels................................................................... 23 Why Cool Electronics in the First Place?................................... 4 Quiet Vortex A/C Enclosure Coolers, Type 4/4X/12................... 198 Rack-Mountable Assemblies.................................................. 256 Rack-Mountable Blowers....................................................... 260 Rack-Mountable Fan Package................................................ 266 Rack-Mount Fan Speed Control.............................................. 259 SCCR Requirements per UL (Condensed version)...................... 24 Sealed Enclosure Cooling......................................................... 5 Sealed vs. Fresh Air Enclosure Cooling...................................... 6 Semiconductor Heaters......................................................... 301 SF Side-Mount...................................................................... 212 SF/ST Replacement Filters..................................................... 241 Simple Chart Method................................................................ 9 Sources of Heat........................................................................ 4 SPECTRACOOL™ Compact Indoor............................................ 70 SPECTRACOOL™ Indoor/Outdoor............................................. 28 SPECTRACOOL™ Narrow Indoor/Outdoor.................................. 52 SR Top-Mount....................................................................... 236 Stainless Steel Pressure Compensation................................. 316 Standards Organization Summary and Directory Overview........ 22 Step 1. Determine Delta-T (ΔT)...................................... 17 Step 2. Determine Internal Heat Load...................................... 17 Step 3. Determine Free Airflow................................................ 18 Step 4. Estimate System Impedance....................................... 19 Step 5. Select Your Air Mover.................................................. 19 ST Thin Side-Mount............................................................... 230 Temperature Control Switch................................................... 312 TFP EMC Upgrade Kit............................................................. 247 TFP Exhaust Grilles............................................................... 246 TFP Optional Grilles and Replacement Filters......................... 246 TFP Side-Mount.................................................................... 242 The Consequences of Damaging Heat........................................ 4 Thermoelectric Condensate Manager..................................... 193 Thermoelectric Coolers Indoor/Outdoor.................................. 184 Thermoelectric Temperature Controller.................................. 192 Thermostat Controller........................................................... 308 Touch-Safe Heaters............................................................... 300 Trend Toward More Damaging Heat........................................... 4 T-SERIES Compact Outdoor..................................................... 80 T-SERIES Large Capacity Outdoor........................................... 106 T-SERIES Mid-size Outdoor..................................................... 88 Ventilator.............................................................................. 292 Mechanical Hygrostat............................................................ 311 Vent Kit................................................................................. 292 Outdoor Filter Fan and Exhaust Package................................ 248 Vortex A/C Enclosure Coolers, Hazardous Location.................. 202 Vortex Coolers Indoor/Outdoor............................................... 194 324 Index SUBJECT TO CHANGE WITHOUT NOTICE EQUIPMENT PROTECTION
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Instance ID : uuid:cb71f7f6-0d61-41fc-b22d-3bf5fca8fbd7 Original Document ID : adobe:docid:indd:34f4a30f-e906-11dd-a430-8424179fca06 Document ID : xmp.id:4F069F2EAA8EE311BAC0D93E4D814689 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:43E0A695DD8DE311BAC0D93E4D814689 Derived From Document ID : xmp.did:6D9C24A16963E3118633857D84DF3BDA Derived From Original Document ID: adobe:docid:indd:34f4a30f-e906-11dd-a430-8424179fca06 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Windows) History Changed : / History When : 2014:02:05 15:14:40-06:00 Create Date : 2014:02:05 15:14:40-06:00 Modify Date : 2014:02:05 15:32:54-06:00 Metadata Date : 2014:02:05 15:32:54-06:00 Creator Tool : Adobe InDesign CS6 (Windows) Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Page Count : 328 Creator : Adobe InDesign CS6 (Windows)EXIF Metadata provided by EXIF.tools